  1. CERTS Microgrid Laboratory Test Bed

    Energy Technology Data Exchange (ETDEWEB)

    Eto, Joe; Lasseter, Robert; Schenkman, Ben; Stevens, John; Klapp, Dave; Volkommer, Harry; Linton, Ed; Hurtado, Hector; Roy, Jean

    2009-06-18

    The objective of the CERTS Microgrid Test Bed project was to enhance the ease of integrating energy sources into a microgrid. The project accomplished this objective by developing and demonstrating three advanced techniques, collectively referred to as the CERTS Microgrid concept, that significantly reduce the level of custom field engineering needed to operate microgrids consisting of generating sources less than 100kW. The techniques comprising the CERTS Microgrid concept are: 1) a method for effecting automatic and seamless transitions between grid-connected and islanded modes of operation, islanding the microgrid's load from a disturbance, thereby maintaining a higher level of service, without impacting the integrity of the utility's electrical power grid; 2) an approach to electrical protection within a limited source microgrid that does not depend on high fault currents; and 3) a method for microgrid control that achieves voltage and frequency stability under islanded conditions without requiring high-speed communications between sources. These techniques were demonstrated at a full-scale test bed built near Columbus, Ohio and operated by American Electric Power. The testing fully confirmed earlier research that had been conducted initially through analytical simulations, then through laboratory emulations,and finally through factory acceptance testing of individual microgrid components. The islanding and resychronization method met all Institute of Electrical and Electronics Engineers Standard 1547 and power quality requirements. The electrical protection system was able to distinguish between normal and faulted operation. The controls were found to be robust under all conditions, including difficult motor starts and high impedance faults. The results from these tests are expected to lead to additional testing of enhancements to the basic techniques at the test bed to improve the business case for microgrid technologies, as well to field

  2. CERTS Microgrid Laboratory Test Bed

    Energy Technology Data Exchange (ETDEWEB)

    ETO, J.; LASSETER, R.; SCHENKMAN, B.; STEVENS, J.; KLAPP, D.; VOLKOMMER, H.; LINTON, E.; HURTADO, H.; ROY, J.

    2010-06-08

    The objective of the CERTS Microgrid Test Bed project was to enhance the ease of integrating energy sources into a microgrid. The project accomplished this objective by developing and demonstrating three advanced techniques, collectively referred to as the CERTS Microgrid concept, that significantly reduce the level of custom field engineering needed to operate microgrids consisting of generating sources less than 100kW. The techniques comprising the CERTS Microgrid concept are: 1 a method for effecting automatic and seamless transitions between grid-connected and islanded modes of operation, islanding the microgrid's load from a disturbance, thereby maintaining a higher level of service, without impacting the integrity of the utility's electrical power grid; 2 an approach to electrical protection within a limited source microgrid that does not depend on high fault currents; and 3 a method for microgrid control that achieves voltage and frequency stability under islanded conditions without requiring high-speed communications between sources.

  3. CERTS Microgrid Laboratory Test Bed

    Energy Technology Data Exchange (ETDEWEB)

    Lasseter, R. H.; Eto, J. H.; Schenkman, B.; Stevens, J.; Volkmmer, H.; Klapp, D.; Linton, E.; Hurtado, H.; Roy, J.

    2010-06-08

    CERTS Microgrid concept captures the emerging potential of distributed generation using a system approach. CERTS views generation and associated loads as a subsystem or a 'microgrid'. The sources can operate in parallel to the grid or can operate in island, providing UPS services. The system can disconnect from the utility during large events (i.e. faults, voltage collapses), but may also intentionally disconnect when the quality of power from the grid falls below certain standards. CERTS Microgrid concepts were demonstrated at a full-scale test bed built near Columbus, Ohio and operated by American Electric Power. The testing fully confirmed earlier research that had been conducted initially through analytical simulations, then through laboratory emulations, and finally through factory acceptance testing of individual microgrid components. The islanding and resynchronization method met all Institute of Electrical and Electronics Engineers Standard 1547 and power quality requirements. The electrical protection system was able to distinguish between normal and faulted operation. The controls were found to be robust under all conditions, including difficult motor starts and high impedance faults.

  4. CERTS Microgrid Laboratory Test Bed - PIER Final Project Report

    Energy Technology Data Exchange (ETDEWEB)

    Eto, Joseph H.; Eto, Joseph H.; Lasseter, Robert; Schenkman, Ben; Klapp, Dave; Linton, Ed; Hurtado, Hector; Roy, Jean; Lewis, Nancy Jo; Stevens, John; Volkommer, Harry

    2008-07-25

    The objective of the CERTS Microgrid Laboratory Test Bed project was to enhance the ease of integrating small energy sources into a microgrid. The project accomplished this objective by developing and demonstrating three advanced techniques, collectively referred to as the CERTS Microgrid concept, that significantly reduce the level of custom field engineering needed to operate microgrids consisting of small generating sources. The techniques comprising the CERTS Microgrid concept are: 1) a method for effecting automatic and seamless transitions between grid-connected and islanded modes of operation; 2) an approach to electrical protection within the microgrid that does not depend on high fault currents; and 3) a method for microgrid control that achieves voltage and frequency stability under islanded conditions without requiring high-speed communications. The techniques were demonstrated at a full-scale test bed built near Columbus, Ohio and operated by American Electric Power. The testing fully confirmed earlier research that had been conducted initially through analytical simulations, then through laboratory emulations, and finally through factory acceptance testing of individual microgrid components. The islanding and resychronization method met all Institute of Electrical and Electronics Engineers 1547 and power quality requirements. The electrical protections system was able to distinguish between normal and faulted operation. The controls were found to be robust and under all conditions, including difficult motor starts. The results from these test are expected to lead to additional testing of enhancements to the basic techniques at the test bed to improve the business case for microgrid technologies, as well to field demonstrations involving microgrids that involve one or mroe of the CERTS Microgrid concepts.

  5. Flexible System Integration and Advanced Hierarchical Control Architectures in the Microgrid Research Laboratory of Aalborg University

    DEFF Research Database (Denmark)

    Meng, Lexuan; Hernández, Adriana Carolina Luna; Diaz, Enrique Rodriguez

    2016-01-01

    This paper presents the system integration and hierarchical control implementation in an inverter-based microgrid research laboratory (MGRL) in Aalborg University, Denmark. MGRL aims to provide a flexible experimental platform for comprehensive studies of microgrids. The structure of the laboratory...... system supervision, advanced secondary and tertiary management are realized in a microgrid central controller. The software and hardware schemes are described. Several example case studies are introduced and performed in order to achieve power quality regulation, energy management and flywheel energy...

  6. Microgrids

    DEFF Research Database (Denmark)

    Soshinskaya, Mariya; Graus, Wina; Guerrero, Josep M.

    2014-01-01

    barriers were identified and grouped into four categories: technical, regulatory, financial, and stakeholder, based on the literature and overlying patterns recognized amongst the thirteen case studies. The most common technical barriers include problems with technology components, dual-mode switching from...... grid-connected to island mode, power quality and control, and protection issues. There is extensive research on how to overcome these issues, so technical solutions are becoming available yet case specific. Regulatory barriers exist due to interconnection rules with the main grid and the prohibition...... of bi-directional power flow and local power trading between microgrid and the main network. The latter issue is the barrier experienced most often and has only recently been addressed, so solutions need further research. The main financial barrier is still the burden of high investment and replacement...

  7. Microgrid-Ready Solar PV; NREL (National Renewable Energy Laboratory)

    Energy Technology Data Exchange (ETDEWEB)

    None

    2015-07-01

    Designing new solar projects to be 'microgrid-ready' enables the U.S. DoD, other federal agencies, and the private sector to plan future microgrid initiatives to utilize solar PV as a generating resource. This fact sheet provides background information with suggested language for several up-front considerations that can be added to a solar project procurement or request for proposal (RFP) that will help ensure that PV systems are built for future microgrid connection.

  8. Intelligent DC Microgrid Living Laboratories - A Chinese-Danish Cooperation Project

    DEFF Research Database (Denmark)

    Diaz, Enrique Rodriguez; Su, Xiaoling; Savaghebi, Mehdi

    2015-01-01

    This paper presents a research project focus on the development of future intelligent direct-current (DC) microgrids which is being deployed for highly efficient integration of distributed generation and modern electronic loads. The project is based on the collaboration between research institutes...... in China and Denmark, aiming to explore the different aspects of DC microgrids: design, modelling, control, coordination, communications and management. In addition, a future Living Laboratory will also be integrated into the Intelligent DC Microgrids Laboratory, which will serve as demonstration facility...... for low voltage direct-current (LVDC) distribution systems. Research is carried out in both Intelligent DC Microgrid Laboratories, focused on industry in China and residential applications in Denmark....

  9. Integrated Electrical and Thermal Grid Facility - Testing of Future Microgrid Technologies

    OpenAIRE

    2015-01-01

    This paper describes the Experimental Power Grid Centre (EPGC) microgrid test facility, which was developed to enable research, development and testing for a wide range of distributed generation and microgrid technologies. The EPGC microgrid facility comprises a integrated electrical and thermal grid with a flexible and configurable architecture, and includes various distributed energy resources and emulators, such as generators, renewable, energy storage technologies and programmable load ba...

  10. Laboratory Tests

    Science.gov (United States)

    Laboratory tests check a sample of your blood, urine, or body tissues. A technician or your doctor ... compare your results to results from previous tests. Laboratory tests are often part of a routine checkup ...

  11. Design and Field Tests of an Inverted Based Remote MicroGrid on a Korean Island

    Directory of Open Access Journals (Sweden)

    Woo-Kyu Chae

    2015-08-01

    Full Text Available In this paper, we present the results of an economic feasibility study and propose a system structure to test and maintain electrical stability. In addition, we present real operation results after constructing a remote microgrid on an island in South Korea. To perform the economic feasibility study, a commercial tool called HOMER was used. The developed remote microgrid consists of a 400 kW wind turbine (WT generator, 314 kW photovoltaic (PV generator, 500 kVA × 2 grid forming inverter, 3 MWh lithium ion battery, and an energy management system (EMS. The predicted renewable energy fraction was 91% and real operation result was 82%. The frequency maintaining rate of the diesel power plants was 57% but the remote microgrid was 100%. To improve the operating efficiency of the remote microgrid, we investigated the output range of a diesel generator.

  12. Integrated Electrical and Thermal Grid Facility - Testing of Future Microgrid Technologies

    Directory of Open Access Journals (Sweden)

    Sundar Raj Thangavelu

    2015-09-01

    Full Text Available This paper describes the Experimental Power Grid Centre (EPGC microgrid test facility, which was developed to enable research, development and testing for a wide range of distributed generation and microgrid technologies. The EPGC microgrid facility comprises a integrated electrical and thermal grid with a flexible and configurable architecture, and includes various distributed energy resources and emulators, such as generators, renewable, energy storage technologies and programmable load banks. The integrated thermal grid provides an opportunity to harness waste heat produced by the generators for combined heat, power and cooling applications, and support research in optimization of combined electrical-thermal systems. Several case studies are presented to demonstrate the testing of different control and operation strategies for storage systems in grid-connected and islanded microgrids. One of the case studies also demonstrates an integrated thermal grid to convert waste heat to useful energy, which thus far resulted in a higher combined energy efficiency. Experiment results confirm that the facility enables testing and evaluation of grid technologies and practical problems that may not be apparent in a computer simulated environment.

  13. Design and implementation of co-operative control strategy for hybrid AC/DC microgrids

    Science.gov (United States)

    Mahmud, Rasel

    This thesis is mainly divided in two major sections: 1) Modeling and control of AC microgrid, DC microgrid, Hybrid AC/DC microgrid using distributed co-operative control, and 2) Development of a four bus laboratory prototype of an AC microgrid system. At first, a distributed cooperative control (DCC) for a DC microgrid considering the state-of-charge (SoC) of the batteries in a typical plug-in-electric-vehicle (PEV) is developed. In DC microgrids, this methodology is developed to assist the load sharing amongst the distributed generation units (DGs), according to their ratings with improved voltage regulation. Subsequently, a DCC based control algorithm for AC microgrid is also investigated to improve the performance of AC microgrid in terms of power sharing among the DGs, voltage regulation and frequency deviation. The results validate the advantages of the proposed methodology as compared to traditional droop control of AC microgrid. The DCC-based control methodology for AC microgrid and DC microgrid are further expanded to develop a DCC-based power management algorithm for hybrid AC/DC microgrid. The developed algorithm for hybrid microgrid controls the power flow through the interfacing converter (IC) between the AC and DC microgrids. This will facilitate the power sharing between the DGs according to their power ratings. Moreover, it enables the fixed scheduled power delivery at different operating conditions, while maintaining good voltage regulation and improved frequency profile. The second section provides a detailed explanation and step-by-step design and development of an AC/DC microgrid testbed. Controllers for the three-phase inverters are designed and tested on different generation units along with their corresponding inductor-capacitor-inductor (LCL) filters to eliminate the switching frequency harmonics. Electric power distribution line models are developed to form the microgrid network topology. Voltage and current sensors are placed in the proper

  14. Networked Microgrids Scoping Study

    Energy Technology Data Exchange (ETDEWEB)

    Starke, Michael R. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2016-10-01

    While the utilization of a microgrid for local power reliability during grid outage and emergencies is a well-known benefit, the integration of microgrids with the broader electrical distribution system will allow for seamless interaction with distribution system operations, contributing to resource and economic optimization, enhanced reliability and resiliency, and improved power quality. By virtue of integration with the distribution system, multiple microgrids should be networked and collectively known as networked microgrids. As a follow-up to the work conducted by Oak Ridge National Laboratory on a microgrid controller [the Complete System-level Efficient and Interoperable Solution for Microgrid Integrated Controls (CSEISMIC)], the main goal of this work is to identify the next steps for bringing microgrid research to the utility industry, particularly as a resource for enhancing efficiency, reliability, and resilience. Various R&D needs for the integration of microgrids into the distribution system have been proposed, including interconnection types, communications, control architectures, quantification of benefits, functional requirements, and various operational issues.

  15. Cyber-Physical Test Platform for Microgrids: Combining Hardware, Hardware-in-the-Loop, and Network-Simulator-in-the-Loop

    Energy Technology Data Exchange (ETDEWEB)

    Nelson, Austin; Chakraborty, Sudipta; Wang, Dexin; Singh, Pawan; Cui, Qiang; Yang, Liuqing; Suryanarayanan, Siddharth

    2016-11-14

    This paper presents a cyber-physical testbed, developed to investigate the complex interactions between emerging microgrid technologies such as grid-interactive power sources, control systems, and a wide variety of communication platforms and bandwidths. The cyber-physical testbed consists of three major components for testing and validation: real time models of a distribution feeder model with microgrid assets that are integrated into the National Renewable Energy Laboratory's (NREL) power hardware-in-the-loop (PHIL) platform; real-time capable network-simulator-in-the-loop (NSIL) models; and physical hardware including inverters and a simple system controller. Several load profiles and microgrid configurations were tested to examine the effect on system performance with increasing channel delays and router processing delays in the network simulator. Testing demonstrated that the controller's ability to maintain a target grid import power band was severely diminished with increasing network delays and laid the foundation for future testing of more complex cyber-physical systems.

  16. Facility Microgrids

    Energy Technology Data Exchange (ETDEWEB)

    Ye, Z.; Walling, R.; Miller, N.; Du, P.; Nelson, K.

    2005-05-01

    Microgrids are receiving a considerable interest from the power industry, partly because their business and technical structure shows promise as a means of taking full advantage of distributed generation. This report investigates three issues associated with facility microgrids: (1) Multiple-distributed generation facility microgrids' unintentional islanding protection, (2) Facility microgrids' response to bulk grid disturbances, and (3) Facility microgrids' intentional islanding.

  17. FOOD SAFETY TESTING LABORATORY

    Data.gov (United States)

    Federal Laboratory Consortium — This laboratory develops screening assays, tests and modifies biosensor equipment, and optimizes food safety testing protocols for the military and civilian sector...

  18. Equivalent Simplification Method of Micro-Grid

    Directory of Open Access Journals (Sweden)

    Cai Changchun

    2013-09-01

    Full Text Available The paper concentrates on the equivalent simplification method for the micro-grid system connection into distributed network. The equivalent simplification method proposed for interaction study between micro-grid and distributed network. Micro-grid network, composite load, gas turbine synchronous generation, wind generation are equivalent simplification and parallel connect into the point of common coupling. A micro-grid system is built and three phase and single phase grounded faults are performed for the test of the equivalent model of micro-grid. The simulation results show that the equivalent model of micro-grid is effective, and the dynamic of equivalent model is similar with the detailed model of micro-grid. The equivalent simplification method for the micro-grid network and distributed components is suitable for the study of micro-grid.  

  19. Smart Metering System for Microgrids

    DEFF Research Database (Denmark)

    Palacios-Garcia, Emilio; Guan, Yajuan; Savaghebi, Mehdi

    2015-01-01

    Smart meters are the cornerstone in the new conception of the electrical network or Smart Grid (SG), providing detailed information about users' energy consumption and allowing the suppliers to remotely collect data for billing. Nevertheless, their features are not only useful for the energy...... will expose an example of Smart Meters integration in a Microgrid scenario, which is the Intelligent Microgrid Lab of Aalborg University (AAU). To do this, first the installation available in the Microgrid Lab will be introduced. Then, three different test scenarios and their respective results...... will be presented, regarding the capabilities of this system and the advantages of integration the Smart Meters information in the Microgrid control....

  20. Mechanical Testing Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — NETL’s Mechanical Testing Laboratory in Albany, OR, helps researchers investigate materials that can withstand the heat and pressure commonly found in fossil energy...

  1. Application of Autonomous Spacecraft Power Control Technology to Terrestrial Microgrids

    Science.gov (United States)

    Dever, Timothy P.; Trase, Larry M.; Soeder, James F.

    2014-01-01

    This paper describes the potential of the power campus located at the NASA Glenn Research Center (GRC) in Cleveland, Ohio for microgrid development. First, the benefits provided by microgrids to the terrestrial power grid are described, and an overview of Technology Needs for microgrid development is presented. Next, GRC's work on development of autonomous control for manned deep space vehicles, which are essentially islanded microgrids, is covered, and contribution of each of these developments to the microgrid Technology Needs is detailed. Finally, a description is provided of GRC's existing physical assets which can be applied to microgrid technology development, and a phased plan for development of a microgrid test facility is presented.

  2. Shipboard Microgrids

    DEFF Research Database (Denmark)

    Guerrero, Josep M.; Jin, Zheming; Liu, Wenzhao

    2016-01-01

    electrical isolated systems are being solved in other terrestrial microgrid applications, so that many ideas and concepts can be shifted and adapted in order to reduce the fuel consumption in marine applications. Compared with terrestrial microgrid applications, the concept of AC and DC SMGs are presented...

  3. Understanding Laboratory Tests

    Science.gov (United States)

    ... and Drug Administration (FDA) regulates the development and marketing of all laboratory tests that use test kits ... are of great interest in cancer medicine because research suggests that levels of ... sequencing methods are being developed to provide gene mutation profiles ...

  4. Methodology for Preliminary Design of Electrical Microgrids

    Energy Technology Data Exchange (ETDEWEB)

    Jensen, Richard P. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Stamp, Jason E. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Eddy, John P. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Henry, Jordan M [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Munoz-Ramos, Karina [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Abdallah, Tarek [U.S. Army Corps of Engineers, Washington, DC (United States)

    2015-09-30

    Many critical loads rely on simple backup generation to provide electricity in the event of a power outage. An Energy Surety Microgrid TM can protect against outages caused by single generator failures to improve reliability. An ESM will also provide a host of other benefits, including integration of renewable energy, fuel optimization, and maximizing the value of energy storage. The ESM concept includes a categorization for microgrid value proposi- tions, and quantifies how the investment can be justified during either grid-connected or utility outage conditions. In contrast with many approaches, the ESM approach explic- itly sets requirements based on unlikely extreme conditions, including the need to protect against determined cyber adversaries. During the United States (US) Department of Defense (DOD)/Department of Energy (DOE) Smart Power Infrastructure Demonstration for Energy Reliability and Security (SPIDERS) effort, the ESM methodology was successfully used to develop the preliminary designs, which direct supported the contracting, construction, and testing for three military bases. Acknowledgements Sandia National Laboratories and the SPIDERS technical team would like to acknowledge the following for help in the project: * Mike Hightower, who has been the key driving force for Energy Surety Microgrids * Juan Torres and Abbas Akhil, who developed the concept of microgrids for military installations * Merrill Smith, U.S. Department of Energy SPIDERS Program Manager * Ross Roley and Rich Trundy from U.S. Pacific Command * Bill Waugaman and Bill Beary from U.S. Northern Command * Melanie Johnson and Harold Sanborn of the U.S. Army Corps of Engineers Construc- tion Engineering Research Laboratory * Experts from the National Renewable Energy Laboratory, Idaho National Laboratory, Oak Ridge National Laboratory, and Pacific Northwest National Laboratory

  5. Design and testing of a centralized protection scheme for micro-grids

    Institute of Scientific and Technical Information of China (English)

    Sohrab Mirsaeidi; Dalila Mat Said; Mohammad Wazir Mustafa; Mohammad Hafiz Habibuddin; Kimia Ghaffari

    2015-01-01

    Micro-grids comprise low voltage distribution systems with distributed energy resources (DERs) and controllable loads which can operate connected to the medium voltage grid or islanded in a controlled coordinated way. This concept aims to move from “connect and forget” philosophy towards a full integration of DERs. Micro-grids can provide numerous economic and environmental benefits for end-customers, utilities and society. However, their implementation poses great technical challenges, such as a new philosophy in design of protection systems. In this work, a micro-grid protection scheme is presented based on positive-sequence component using phasor measurement units (PMUs) and a central protection unit (CPU). The salient feature of the proposed scheme in comparison with the previous works is that it has the ability to protect both radial and looped micro-grids against different types of faults with the capability of single-phase tripping. Furthermore, since the CPU is capable of updating its pickup values (upstream and downstream equivalent positive-sequence impedances of each line) after the first change in the micro-grid configuration (such as transferring from grid-connected to islanded mode and or disconnection of a line, bus, or DER either in grid-connected mode or in islanded mode), it can protect micro-grid against subsequent faults. Finally, in order to verify the effectiveness of the suggested scheme and the CPU, several simulations have been undertaken by using DIgSILENT PowerFactory and MATLAB software packages.

  6. Adaptive Distance Protection for Microgrids

    DEFF Research Database (Denmark)

    Lin, Hengwei; Guerrero, Josep M.; Quintero, Juan Carlos Vasquez

    2015-01-01

    Due to the increasing penetration of distributed generation resources, more and more microgrids can be found in distribution systems. This paper proposes a phasor measurement unit based distance protection strategy for microgrids in distribution system. At the same time, transfer tripping scheme...... is adopted to accelerate the tripping speed of the relays on the weak lines. The protection methodology is tested on a mid-voltage microgrid network in Aalborg, Denmark. The results show that the adaptive distance protection methodology has good selectivity and sensitivity. What is more, this system also has...

  7. Applying DER-CAM for IIT Microgrid Explansion Planning

    Energy Technology Data Exchange (ETDEWEB)

    Shahidehpour, Mohammad [Illinois Inst. of Technology, Chicago, IL (United States); Li, Zuyi [Illinois Inst. of Technology, Chicago, IL (United States); Wang, Jianhui [Argonne National Lab. (ANL), Argonne, IL (United States); Chen, Chen [Argonne National Lab. (ANL), Argonne, IL (United States)

    2016-04-19

    The Distributed Energy Resources Customer Adoption Model (DER-CAM) is an economic and environmental model of customer DER adoption. This model has been in development at the Lawrence Berkeley National Laboratory since 2000. The objective of the model is to find optimal DER investments while minimizing total energy costs or carbon dioxide (CO2) emissions, or achieving a weighted objective that simultaneously considers both criteria. The Illinois Institute of Technology (IIT) Microgrid project started in August 2008, and the majority of the project was completed in May 2013. IIT Microgrid, funded mostly by a grant from the U.S. Department of Energy as well as State and philanthropic contributions, empowers the campus consumers with the objective of establishing a smart microgrid that is highly reliable, economically viable, environmentally friendly, fuel-efficient, and resilient in extreme circumstances with a self-healing capability. In this project, we apply DER-CAM to study the expansion planning of the IIT Microgrid. First, the load data, environmental data, utility data, and technology data for the IIT Microgrid are gathered and organized to follow the DER-CAM input requirements. Then, DERCAM is applied to study the expansion planning of the IIT Microgrid for different cases, where different objectives in DER-CAM and different utility conditions are tested. Case 1 considers the objective of minimizing energy costs with fixed utility rates and 100% electric utility availability. Case 2 considers the objective of minimizing energy costs with real-time utility rates and 4 emergency weeks when the IIT Microgrid does not have access to the electric utility grid and has to operate in island mode. In Case 3, the utility rates are restored to fixed values and 100% electric utility availability is assumed, but a weighted multi-objective (Obj: a × costs + b × CO2 emissions, where a and b are weights for cost minimization and CO2 emissions minimization) is utilized to

  8. Implementation of hierarchical control in DC microgrids

    DEFF Research Database (Denmark)

    Jin, Chi; Wang, Peng; Xiao, Jianfang

    2014-01-01

    DC microgrids are becoming popular in low-voltage distribution systems due to the better compatibility with photovoltaic panels, electric vehicles, and dc loads. This paper presents a practical dc microgrid developed in the Water and Energy Research Laboratory (WERL) in the Nanyang University...

  9. Microgrid Plant Control Design and Development

    Energy Technology Data Exchange (ETDEWEB)

    Wiegman, Herman; Baone, Chaitanya

    2017-08-14

    This report discusses the technical performance of the proposed microgrid at Potsdam, New York, and the enhanced microgrid controller platform. The test objectives were outlined by the DOE, and summary results and discussion are given for each objective. The findings show that the proposed Potsdam, NY microgrid would have a significant impact on the regional CO2 emissions, the amount of imported energy from the utility, and the resiliency of the critical loads. Additionally, the enhanced microgrid control system developed for this project was tested to be compliant with IEEE 1547 standards, and able to generate revenues to help offset energy costs by way of participation in ancillary services.

  10. Analysis and Application of Microgrids

    Science.gov (United States)

    Yue, Lu

    New trends of generating electricity locally and utilizing non-conventional or renewable energy sources have attracted increasing interests due to the gradual depletion of conventional fossil fuel energy sources. The new type of power generation is called Distributed Generation (DG) and the energy sources utilized by Distributed Generation are termed Distributed Energy Sources (DERs). With DGs embedded in the distribution networks, they evolve from passive distribution networks to active distribution networks enabling bidirectional power flows in the networks. Further incorporating flexible and intelligent controllers and employing future technologies, active distribution networks will turn to a Microgrid. A Microgrid is a small-scale, low voltage Combined with Heat and Power (CHP) supply network designed to supply electrical and heat loads for a small community. To further implement Microgrids, a sophisticated Microgrid Management System must be integrated. However, due to the fact that a Microgrid has multiple DERs integrated and is likely to be deregulated, the ability to perform real-time OPF and economic dispatch with fast speed advanced communication network is necessary. In this thesis, first, problems such as, power system modelling, power flow solving and power system optimization, are studied. Then, Distributed Generation and Microgrid are studied and reviewed, including a comprehensive review over current distributed generation technologies and Microgrid Management Systems, etc. Finally, a computer-based AC optimization method which minimizes the total transmission loss and generation cost of a Microgrid is proposed and a wireless communication scheme based on synchronized Code Division Multiple Access (sCDMA) is proposed. The algorithm is tested with a 6-bus power system and a 9-bus power system.

  11. Microgrids and distributed generation systems: Control, operation, coordination and planning

    Science.gov (United States)

    Che, Liang

    requires proper protection schemes that effectively function in both grid-connected and island modes. This chapter presents a communication-assisted four-level hierarchical protection strategy for high-reliability microgrids, and tests the proposed protection strategy based on a loop structured microgrid. The simulation results demonstrate the proposed strategy to be an effective and efficient option for microgrid protection. Additionally, microgrid topology ought to be optimally planned. To address the microgrid topology planning, a graph-partitioning and integer-programming integrated methodology is proposed. This work is not included in the dissertation. Interested readers can refer to our related publication.

  12. Wind Structural Testing Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — This facility provides office space for industry researchers, experimental laboratories, computer facilities for analytical work, and space for assembling components...

  13. Wind Structural Testing Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — This facility provides office space for industry researchers, experimental laboratories, computer facilities for analytical work, and space for assembling components...

  14. Testing of a Predictive Control Strategy for Balancing Renewable Sources in a Microgrid

    DEFF Research Database (Denmark)

    Marinelli, Mattia; Sossan, Fabrizio; Costanzo, Giuseppe Tommaso

    2014-01-01

    This paper presents the design of a control strategy for the energy management of a grid-connected microgrid with local distributed energy resources as: 10-kW photovoltaic plant, 11-kW wind turbine, and 15-kW–190-kWh vanadium-based electric storage system. According to future regulations, the ren......This paper presents the design of a control strategy for the energy management of a grid-connected microgrid with local distributed energy resources as: 10-kW photovoltaic plant, 11-kW wind turbine, and 15-kW–190-kWh vanadium-based electric storage system. According to future regulations......, the renewable energy producers will also have to provide a day-ahead hourly production plan. The overall idea is, by knowing the meteorological forecasts for the next 24 h, to dispatch the microgrid in order to be able to grant the scheduled hourly production by means of proper management of the storage system...

  15. Energy Management of a Hybrid AC–DC Micro-Grid Based on a Battery Testing System

    Directory of Open Access Journals (Sweden)

    Bo Long

    2015-02-01

    Full Text Available Energy Recovery Battery Testing Systems (ERBTS plays an important role in battery manufacture. The conventional ERBTS configuration contains a fundamental transformer, and a bidirectional Direct Current (DC–DC and Alternating Current (AC–DC converter. All ERBTS are connected in parallel, thus constituting a special and complicated AC micro-grid system. Aiming at addressing their low energy recovery efficiency, complex grid-connected control algorithm issues for islanded detection, and complicated power circuit topology issues, a hierarchical DC-link voltage hybrid AC–DC micro-grid that contains composite energy storing devices is proposed. Moreover, an energy management optimal scheme for the proposed scheme is put forward. The system configuration of the proposed scheme is described in detail. Compared to the conventional scheme, the proposed scheme has the merits of simplified power circuit topology, no need for phase synchronous control, and much higher energy recovery efficiency and reliability. The validity and effectiveness of the proposed technique is verified through numerous experimental results.

  16. Metallurgical Laboratory and Components Testing

    Data.gov (United States)

    Federal Laboratory Consortium — In the field of metallurgy, TTC is equipped to run laboratory tests on track and rolling stock components and materials. The testing lab contains scanning-electron,...

  17. Development of Hardware-in-the-loop Microgrid Testbed

    Energy Technology Data Exchange (ETDEWEB)

    Xiao, Bailu [ORNL; Prabakar, Kumaraguru [ORNL; Starke, Michael R [ORNL; Liu, Guodong [ORNL; Dowling, Kevin [University of Tennessee, Knoxville (UTK); Ollis, T Ben [ORNL; Irminger, Philip [ORNL; Xu, Yan [ORNL; Dimitrovski, Aleksandar D [ORNL

    2015-01-01

    A hardware-in-the-loop (HIL) microgrid testbed for the evaluation and assessment of microgrid operation and control system has been presented in this paper. The HIL testbed is composed of a real-time digital simulator (RTDS) for modeling of the microgrid, multiple NI CompactRIOs for device level control, a prototype microgrid energy management system (MicroEMS), and a relay protection system. The applied communication-assisted hybrid control system has been also discussed. Results of function testing of HIL controller, communication, and the relay protection system are presented to show the effectiveness of the proposed HIL microgrid testbed.

  18. Microgrids architectures and control

    CERN Document Server

    Hatziargyriou, Nikos

    2014-01-01

    Microgrids are the most innovative area in the electric power industry today. Future microgrids could exist as energy-balanced cells within existing power distribution grids or stand-alone power networks within small communities. A definitive presentation on all aspects of microgrids, this text examines the operation of microgrids - their control concepts and advanced architectures including multi-microgrids. It takes a logical approach to overview the purpose and the technical aspects of microgrids, discussing the social, economic and environmental benefits to power system operation. The bo

  19. World of Forensic Laboratory Testing

    Science.gov (United States)

    ... Global Sites Search Help? The World of Forensic Laboratory Testing Share this page: Was this page helpful? ... made-for-television lab scenario, real-life forensic laboratories' analyses of evidence are much slower. For example, ...

  20. Microgrid Controller and Advanced Distribution Management System Survey Report

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Guodong [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Starke, Michael R. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Herron, Andrew N. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2016-07-01

    A microgrid controller, which serves as the heart of a microgrid, is responsible for optimally managing the distributed energy resources, energy storage systems, and responsive demand and for ensuring the microgrid is being operated in an efficient, reliable, and resilient way. As the market for microgrids has blossomed in recently years, many vendors have released their own microgrid controllers to meet the various needs of different microgrid clients. However, due to the absence of a recognized standard for such controllers, vendor-supported microgrid controllers have a range of functionalities that are significantly different from each other in many respects. As a result the current state of the industry has been difficult to assess. To remedy this situation the authors conducted a survey of the functions of microgrid controllers developed by vendors and national laboratories. This report presents a clear indication of the state of the microgrid-controller industry based on analysis of the survey results. The results demonstrate that US Department of Energy funded research in microgrid controllers is unique and not competing with that of industry.

  1. Autonomous Operation of Low Voltage Microgrids

    Directory of Open Access Journals (Sweden)

    Irena Wasiak

    2014-12-01

    Full Text Available The article describes the possibilities of LV microgrids operation in the island mode. Control strategies of energy sources connected to the grid by means of invertors are discussed, either for a microgrid connected to the supplying network or during the island mode operation. The presented results of research were conducted at the Laboratory of Distributed Generation at Lodz University of Technology. The study was performed for two variants of reference voltage source: the battery storage and microturbine respectively.

  2. 微网能量管理系统实时数字仿真测试平台研究%Study on RTDS-based Testing Platform of Microgrid Energy Management System

    Institute of Scientific and Technical Information of China (English)

    吉小鹏; 吴家宏; 金强; 刘云; 杨琦

    2013-01-01

    为了全面测试微网能量管理系统,在深入了解微网系统组成结构、微源控制方法和高级应用控制策略的基础上,对微网系统实时数字仿真(RTDS)测试平台关键技术进行了研究.技术难点在于微网系统测试平台的搭建方案、接口设计和微网电源建模.研究和实验结果表明:所搭建的模型和平台能够反映微网系统的实时控制特性,满足各种不同微网结构的测试要求,可系统地考核微网能量管理系统,为实际微网系统中的研究和工程实施提供测试数据和理论指导.%In order to comprehensively test the microgrid energy management system (MEMS),the microgrid architecture,control method of microsources,protective function and advanced application functions are analyzed thoroughly.Key technologies of RTDS-based testing platform of microgrid system are studied.The technical difficulties lie in the aspects of building scheme of microgrid testing platform,interface design and modeling of microsources.The research and experimental results indicate that the proposed models and the established testing platform meet the real-time control characteristics of microgrid,satisfy the testing needs for different microgrid architectures,test MEMS systematically,and provide theory guidelines and testing data for scientific research and engineering practice of microgrids.

  3. Energy-Water Microgrid Case Study at the University of Arizona's BioSphere 2

    Science.gov (United States)

    Daw, J.; Macknick, J.; Kandt, A.; Giraldez, J.

    2016-12-01

    Microgrids can provide reliable and cost-effective energy services in a variety of conditions and locations. To date, there has been minimal effort invested in developing energy-water microgrids that demonstrate the feasibility and leverage the synergies associated with designing and operating renewable energy and water systems in a coordinated framework. Water and wastewater treatment equipment can be operated in ways to provide ancillary services to the electrical grid and renewable energy can be utilized to power water-related infrastructure, but the potential for co-managed systems has not yet been quantified or fully characterized. Co-management and optimization of energy and water resources could lead to improved reliability and economic operating conditions. Energy-water microgrids could be a promising solution to improve energy and water resource management for islands, rural communities, distributed generation, Defense operations, and many parts of the world lacking critical infrastructure.The National Renewable Energy Laboratory (NREL) and the University of Arizona have been jointly researching energy-water microgrid opportunities through an effort at the university's BioSphere 2 (B2) Earth systems science research facility. B2 is an ideal case study for an energy-water microgrid test site, given its size, its unique mission and operations, the existence and criticality of water and energy infrastructure, and its ability to operate connected-to or disconnected-from the local electrical grid. Moreover, the B2 is a premier facility for undertaking agricultural research, providing an excellent opportunity to evaluate connections and tradeoffs in the food-energy-water nexus. The research effort at B2 identified the technical potential and associated benefits of an energy-water microgrid through the evaluation of energy ancillary services and peak load reductions and quantified the potential for B2 water-related loads to be utilized and modified to provide

  4. Laboratory Testing for Prescription Opioids

    OpenAIRE

    Milone, Michael C.

    2012-01-01

    Opioid analgesic misuse has risen significantly over the past two decades, and these drugs now represent the most commonly abused class of prescription medications. They are a major cause of poisoning deaths in the USA exceeding heroin and cocaine. Laboratory testing plays a role in the detection of opioid misuse and the evaluation of patients with opioid intoxication. Laboratories use both immunoassay and chromatographic methods (e.g., liquid chromatography with mass spectrometry detection),...

  5. Networked Microgrids Scoping Study

    Energy Technology Data Exchange (ETDEWEB)

    Backhaus, Scott N. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Dobriansky, Larisa [General MicroGrids, San Diego, CA (United States); Glover, Steve [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Liu, Chen-Ching [Washington State Univ., Pullman, WA (United States); Looney, Patrick [Brookhaven National Lab. (BNL), Upton, NY (United States); Mashayekh, Salman [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Pratt, Annabelle [National Renewable Energy Lab. (NREL), Golden, CO (United States); Schneider, Kevin [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Stadler, Michael [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Starke, Michael [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Wang, Jianhui [Argonne National Lab. (ANL), Argonne, IL (United States); Yue, Meng [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2016-12-05

    Much like individual microgrids, the range of opportunities and potential architectures of networked microgrids is very diverse. The goals of this scoping study are to provide an early assessment of research and development needs by examining the benefits of, risks created by, and risks to networked microgrids. At this time there are very few, if any, examples of deployed microgrid networks. In addition, there are very few tools to simulate or otherwise analyze the behavior of networked microgrids. In this setting, it is very difficult to evaluate networked microgrids systematically or quantitatively. At this early stage, this study is relying on inputs, estimations, and literature reviews by subject matter experts who are engaged in individual microgrid research and development projects, i.e., the authors of this study The initial step of the study gathered input about the potential opportunities provided by networked microgrids from these subject matter experts. These opportunities were divided between the subject matter experts for further review. Part 2 of this study is comprised of these reviews. Part 1 of this study is a summary of the benefits and risks identified in the reviews in Part 2 and synthesis of the research needs required to enable networked microgrids.

  6. Current Capabilities at SNL for the Integration of Small Modular Reactors onto Smart Microgrids Using Sandia's Smart Microgrid Technology High Performance Computing and Advanced Manufacturing.

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez, Salvador B. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-05-01

    Smart grids are a crucial component for enabling the nation’s future energy needs, as part of a modernization effort led by the Department of Energy. Smart grids and smart microgrids are being considered in niche applications, and as part of a comprehensive energy strategy to help manage the nation’s growing energy demands, for critical infrastructures, military installations, small rural communities, and large populations with limited water supplies. As part of a far-reaching strategic initiative, Sandia National Laboratories (SNL) presents herein a unique, three-pronged approach to integrate small modular reactors (SMRs) into microgrids, with the goal of providing economically-competitive, reliable, and secure energy to meet the nation’s needs. SNL’s triad methodology involves an innovative blend of smart microgrid technology, high performance computing (HPC), and advanced manufacturing (AM). In this report, Sandia’s current capabilities in those areas are summarized, as well as paths forward that will enable DOE to achieve its energy goals. In the area of smart grid/microgrid technology, Sandia’s current computational capabilities can model the entire grid, including temporal aspects and cyber security issues. Our tools include system development, integration, testing and evaluation, monitoring, and sustainment.

  7. Laboratory testing for prescription opioids.

    Science.gov (United States)

    Milone, Michael C

    2012-12-01

    Opioid analgesic misuse has risen significantly over the past two decades, and these drugs now represent the most commonly abused class of prescription medications. They are a major cause of poisoning deaths in the USA exceeding heroin and cocaine. Laboratory testing plays a role in the detection of opioid misuse and the evaluation of patients with opioid intoxication. Laboratories use both immunoassay and chromatographic methods (e.g., liquid chromatography with mass spectrometry detection), often in combination, to yield high detection sensitivity and drug specificity. Testing methods for opioids originated in the workplace-testing arena and focused on detection of illicit heroin use. Analysis for a wide range of opioids is now required in the context of the prescription opioid epidemic. Testing methods have also been primarily based upon urine screening; however, methods for analyzing alternative samples such as saliva, sweat, and hair are available. Application of testing to monitor prescription opioid drug therapy is an increasingly important use of drug testing, and this area of testing introduces new interpretative challenges. In particular, drug metabolism may transform one clinically available opioid into another. The sensitivity of testing methods also varies considerably across the spectrum of opioid drugs. An understanding of opioid metabolism and method sensitivity towards different opioid drugs is therefore essential to effective use of these tests. Improved testing algorithms and more research into the effective use of drug testing in the clinical setting, particularly in pain medicine and substance abuse, are needed.

  8. Harmonic mitigation in islanded microgrids by inverter-interfaced distributed energy resource

    Energy Technology Data Exchange (ETDEWEB)

    Xiongfei Wang

    2012-10-15

    primary droop controllers integrated with virtual output impedance loops and the secondary controllers enabled by the low-bandwidth communication. With the chosen control options of DER inverters, the circulating current characteristics in the droop-controlled parallel three-phase DER inverters are analysed. It is found that the circulating current not only consists of the Positive-Sequence Circulating Current (PSCC) but also contains the Negative-Sequence Circulating Current (NSCC) even when feeding linear balanced loads. It is shown that the presence of the NSCC deteriorates the current quality of inverters and results in unbalanced voltage distortion at certain buses of an islanded microgrid. In order to reduce the NSCC, an improved virtual output impedance loop is proposed, where a negative-sequence virtual resistance is introduced based on the detection of the negative-sequence output current. Moreover, to adapt to the variation of unbalanced loads, a dynamically-tuned negative-sequence resistance is developed. Thus, an autonomous NSCC control that is more suitable for the scattered DER units is achieved and validated via a series of laboratory tests. Under the built islanded microgrid, the control methods of DER inverters for active harmonic conditioning are investigated. Two autonomous harmonic current filtering and resonance damping approaches, i.e. the Resistive-Active Power Filter (R-APF)-based method and the virtual output resistance scheme, are evaluated. It has been found that the large grid-side inductances of DER inverters may lead to either underdamped or aggravated harmonic voltages in the islanded microgrid. To address such a challenge, a Variable Harmonic Impedance (VHI) concept is proposed, where positive resistances and negative inductances are synthesized at the dominant harmonic frequencies. Two case studies, including the single grid-interactive DER inverter and the parallel DER inverters, are carried out. Simulation and laboratory test results are

  9. Clean energy microgrids

    CERN Document Server

    Obara, Shin'ya

    2017-01-01

    This book describes the latest technology in microgrids and economic, environmental and policy aspects of their implementation, including microgrids for cold regions, and future trends. The aim of this work is to give this complete overview of the latest technology around the world, and the interrelation with clean energy systems.

  10. Energy Quality in Microgrids

    Directory of Open Access Journals (Sweden)

    Golovanov Nicolae

    2016-04-01

    Full Text Available Measures for limiting environmental pollution by power plants using fossil fuel sources and for efficient use of local energy sources can cause significant changes in the structure of the electricity distribution networks through the development of micro-grids that can operate practically isolated or connected to the public electricity network, which ensures bilateral exchanges of energy. The microgrid requires a detailed analysis of the level of quality of electricity supplied to the microgrid. The detailed analysis of technical solutions is needed to ensure a necessary level of electric energy quality in practically isolated microgrid. Some of the specific conditions of microgrid operation are analyzed, which will ensure operation of the system at the action of disturbances.

  11. Laboratory Tests of Chameleon Models

    CERN Document Server

    Brax, Philippe; Davis, Anne-Christine; Shaw, Douglas

    2009-01-01

    We present a cursory overview of chameleon models of dark energy and their laboratory tests with an emphasis on optical and Casimir experiments. Optical experiments measuring the ellipticity of an initially polarised laser beam are sensitive to the coupling of chameleons to photons. The next generation of Casimir experiments may be able to unravel the nature of the scalar force mediated by the chameleon between parallel plates.

  12. CAECC Software Testing Laboratory Accredited by CNAL

    Institute of Scientific and Technical Information of China (English)

    2005-01-01

    Software Testing Laboratory of China Aerospace Engineering and Consultation Center (CAECC) is accredited by China National Accreditation Board for Laboratories (CNAL) as the first such laboratory in domestic space industry. Since CNAL is a member of International Laboratory Accreditation Cooperation (ILAC),software testing reports certificated to CAECC are recognized by 45 laboratory accreditation organizations in AsiaPacific region, Europe and America.

  13. Microgrid Central Controller Development and Hierarchical Control Implementation in the Intelligent MicroGrid Lab of Aalborg University

    DEFF Research Database (Denmark)

    Meng, Lexuan; Savaghebi, Mehdi; Andrade, Fabio

    2015-01-01

    This paper presents the development of a microgrid central controller in an inverter-based intelligent microgrid (iMG) lab in Aalborg University, Denmark. The iMG lab aims to provide a flexible experimental platform for comprehensive studies of microgrids. The complete control system applied...... in this lab is based on the hierarchical control scheme for microgrids and includes primary, secondary and tertiary control. The structure of the lab, including the lab facilities, configurations and communication network, is first introduced. Primary control loops are developed in MATLAB....../Simulink and compiled to dSPACEs for local control purposes. In order to realize system supervision and proper secondary and tertiary management, a LabVIEW-based microgrid central controller is also developed. The software and hardware schemes are described. An example case is introduced and tested in the iMG lab...

  14. SENSORY AND CONSUMER TESTING LABORATORY

    Data.gov (United States)

    Federal Laboratory Consortium — These laboratories conduct a wide range of studies to characterize the sensory properties of and consumer responses to foods, beverages, and other consumer products....

  15. Distributed cooperative control of AC microgrids

    Science.gov (United States)

    Bidram, Ali

    In this dissertation, the comprehensive secondary control of electric power microgrids is of concern. Microgrid technical challenges are mainly realized through the hierarchical control structure, including primary, secondary, and tertiary control levels. Primary control level is locally implemented at each distributed generator (DG), while the secondary and tertiary control levels are conventionally implemented through a centralized control structure. The centralized structure requires a central controller which increases the reliability concerns by posing the single point of failure. In this dissertation, the distributed control structure using the distributed cooperative control of multi-agent systems is exploited to increase the secondary control reliability. The secondary control objectives are microgrid voltage and frequency, and distributed generators (DGs) active and reactive powers. Fully distributed control protocols are implemented through distributed communication networks. In the distributed control structure, each DG only requires its own information and the information of its neighbors on the communication network. The distributed structure obviates the requirements for a central controller and complex communication network which, in turn, improves the system reliability. Since the DG dynamics are nonlinear and non-identical, input-output feedback linearization is used to transform the nonlinear dynamics of DGs to linear dynamics. Proposed control frameworks cover the control of microgrids containing inverter-based DGs. Typical microgrid test systems are used to verify the effectiveness of the proposed control protocols.

  16. Educational ultrasound nondestructive testing laboratory.

    Science.gov (United States)

    Genis, Vladimir; Zagorski, Michael

    2008-09-01

    The ultrasound nondestructive evaluation (NDE) of materials course was developed for applied engineering technology students at Drexel University's Goodwin College of Professional Studies. This three-credit, hands-on laboratory course consists of two parts: the first part with an emphasis on the foundations of NDE, and the second part during which ultrasound NDE techniques are utilized in the evaluation of parts and materials. NDE applications are presented and applied through real-life problems, including calibration and use of the latest ultrasonic testing instrumentation. The students learn engineering and physical principles of measurements of sound velocity in different materials, attenuation coefficients, material thickness, and location and dimensions of discontinuities in various materials, such as holes, cracks, and flaws. The work in the laboratory enhances the fundamentals taught during classroom sessions. This course will ultimately result in improvements in the educational process ["The greater expectations," national panel report, http://www.greaterexpectations.org (last viewed February, 2008); R. M. Felder and R. Brent "The intellectual development of Science and Engineering Students. Part 2: Teaching to promote growth," J. Eng. Educ. 93, 279-291 (2004)] since industry is becoming increasingly reliant on the effective application of NDE technology and the demand on NDE specialists is increasing. NDE curriculum was designed to fulfill levels I and II NDE in theory and training requirements, according to American Society for Nondestructive Testing, OH, Recommended Practice No. SNT-TC-1A (2006).

  17. Real-Time Implementation of Islanded Microgrid for Remote Areas

    Directory of Open Access Journals (Sweden)

    Monika Jain

    2016-01-01

    Full Text Available Islanding is a condition in which a microgrid or a portion of power grid, consisting of distributed generation (DG sources, converter, and load, gets disconnected from the utility grid. Under this condition the DG sources in a microgrid must switch to a voltage control mode, in order to provide constant voltage to local loads. In grid connected mode, the microgrid works as current controller and injects power to the main grid, depending on the power generation and local load with suitable market policies. Providing constant voltage at a stable frequency with proper synchronization amongst each DG in a microgrid is a challenge. The complexity of such grid requires careful study and analysis before actual implementation. These challenges of microgrid are addressed using real time OPAL-RT simulation technology. Thus the paper describes an islanded microgrid with master slave controller for power balance, voltage/frequency regulation, and synchronization. Based on an advanced real-time platform named Real-Time Laboratory (RT-LAB, the impacts of the micro sources, load, and converters in an islanded microgrid is studied in this paper. The effectiveness of the proposed controller is analyzed through experimental results under balanced/unbalanced nonlinear loads condition.

  18. Anthropomorphic Test Drive (ATD) Certification Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — The ATD Certification Laboratory consists of several test fixtures to ensure ATDs are functioning correctly and within specifications prior to use in any OP testing....

  19. Putting New Laboratory Tests Into Practice

    Science.gov (United States)

    ... Home Visit Global Sites Search Help? Putting New Laboratory Tests into Practice Share this page: Was this ... of articles that describe how different types of laboratory tests are developed, validated, and made available for ...

  20. Frequency Stability of Hierarchically Controlled Hybrid Photovoltaic-Battery-Hydropower Microgrids

    DEFF Research Database (Denmark)

    Guan, Yajuan; Vasquez, Juan Carlos; Guerrero, Josep M.;

    2014-01-01

    analysis is presented based on small signal models of the hybrid PV-HP microgrid, including 2 MWp PV station, 15.2 MWh battery storage system, and 12.8 MVA hydropower plant. Simulation results of the microgrid and experimental results on a scaled-down laboratory prototype verify the effectiveness......Hybrid photovolvaic battery-hydropower microgrids can increase electricity accessibility and availability in remote areas. In those microgrids with grid-connected and islanded modes capabilities, seamless transition between both modes is needed as well. However, the different resources...

  1. Computing architecture for autonomous microgrids

    Science.gov (United States)

    Goldsmith, Steven Y.

    2015-09-29

    A computing architecture that facilitates autonomously controlling operations of a microgrid is described herein. A microgrid network includes numerous computing devices that execute intelligent agents, each of which is assigned to a particular entity (load, source, storage device, or switch) in the microgrid. The intelligent agents can execute in accordance with predefined protocols to collectively perform computations that facilitate uninterrupted control of the .

  2. An Intelligent Multiagent System for Autonomous Microgrid Operation

    Directory of Open Access Journals (Sweden)

    Tetsuo Kinoshita

    2012-09-01

    Full Text Available A microgrid is an eco-friendly power system because renewable sources such as solar and wind power are used as the main power sources. For this reason, much research, development, and demonstration projects have recently taken place in many countries. Operation is one of the important research topics for microgrids. For efficient and economical microgrid operation, a human operator is required as in other power systems, but it is difficult because there are some restrictions related to operation costs and privacy issues. To overcome the restriction, autonomous operation for microgrids is required. Recently, an intelligent agent system for autonomous microgrid operation has been studied as a potential solution. This paper proposes a multiagent system for autonomous microgrid operation. To build the multiagent system, the functionalities of agents, interactions among agents, and an effective agent protocol have been designed. The proposed system has been implemented by using an ADIPS/DASH framework as an agent platform. The intelligent multiagent system for microgrid operation based on the proposed scheme is tested to show the functionality and feasibility on a distributed environment through the Internet.

  3. Microgrid optimal scheduling considering impact of high penetration wind generation

    Science.gov (United States)

    Alanazi, Abdulaziz

    The objective of this thesis is to study the impact of high penetration wind energy in economic and reliable operation of microgrids. Wind power is variable, i.e., constantly changing, and nondispatchable, i.e., cannot be controlled by the microgrid controller. Thus an accurate forecasting of wind power is an essential task in order to study its impacts in microgrid operation. Two commonly used forecasting methods including Autoregressive Integrated Moving Average (ARIMA) and Artificial Neural Network (ANN) have been used in this thesis to improve the wind power forecasting. The forecasting error is calculated using a Mean Absolute Percentage Error (MAPE) and is improved using the ANN. The wind forecast is further used in the microgrid optimal scheduling problem. The microgrid optimal scheduling is performed by developing a viable model for security-constrained unit commitment (SCUC) based on mixed-integer linear programing (MILP) method. The proposed SCUC is solved for various wind penetration levels and the relationship between the total cost and the wind power penetration is found. In order to reduce microgrid power transfer fluctuations, an additional constraint is proposed and added to the SCUC formulation. The new constraint would control the time-based fluctuations. The impact of the constraint on microgrid SCUC results is tested and validated with numerical analysis. Finally, the applicability of proposed models is demonstrated through numerical simulations.

  4. Energy storage for sustainable microgrid

    CERN Document Server

    Gao, David Wenzhong

    2015-01-01

    Energy Storage for Sustainable Microgrid addresses the issues related to modelling, operation and control, steady-state and dynamic analysis of microgrids with ESS. This book discusses major electricity storage technologies in depth along with their efficiency, lifetime cycles, environmental benefits and capacity, so that readers can envisage which type of storage technology is best for a particular microgrid application. This book offers solutions to numerous difficulties such as choosing the right ESS for the particular microgrid application, proper sizing of ESS for microgrid, as well as

  5. Geotechnical Design Asssisted by Laboratory Testing

    DEFF Research Database (Denmark)

    Foged, Niels; Dysli, Michel; Head, Ken H.;

    1997-01-01

    Eurocode 7 Part 2 is intended to serve as a reference document for the use of laboratory tests for geotechnical design. It covers the execution and interpretation of the most commonly used laboratory tests. The standard aims at ensuring that adequate quality is reached in the execution...... of laboratory tests and their interpretation. Within the framework of European Standardisation, Eurocode 7 Part 1 on the design of geotechnical structures was established. Complementary, Eurocode 7 Part 3 addresses field testing....

  6. Multiple-Time-Scales Hierarchical Frequency Stability Control Strategy of Medium-Voltage Isolated Microgrid

    DEFF Research Database (Denmark)

    Zhao, Zhuoli; Yang, Ping; Guerrero, Josep M.

    2016-01-01

    In this paper, an islanded medium-voltage (MV) microgrid placed in Dongao Island is presented, which integrates renewable-energy-based distributed generations (DGs), energy storage system (ESS), and local loads. In an isolated microgrid without connection to the main grid to support the frequency...... of Zone B. Theoretical analysis, time-domain simulation and field test results under various conditions and scenarios in the Dongao Island microgrid are presented to prove the validity of the introduced control strategy....

  7. Postirradiation Testing Laboratory (327 Building)

    Energy Technology Data Exchange (ETDEWEB)

    Kammenzind, D.E.

    1997-05-28

    A Standards/Requirements Identification Document (S/RID) is the total list of the Environment, Safety and Health (ES and H) requirements to be implemented by a site, facility, or activity. These requirements are appropriate to the life cycle phase to achieve an adequate level of protection for worker and public health and safety, and the environment during design, construction, operation, decontamination and decommissioning, and environmental restoration. S/RlDs are living documents, to be revised appropriately based on change in the site`s or facility`s mission or configuration, a change in the facility`s life cycle phase, or a change to the applicable standards/requirements. S/RIDs encompass health and safety, environmental, and safety related safeguards and security (S and S) standards/requirements related to the functional areas listed in the US Department of Energy (DOE) Environment, Safety and Health Configuration Guide. The Fluor Daniel Hanford (FDH) Contract S/RID contains standards/requirements, applicable to FDH and FDH subcontractors, necessary for safe operation of Project Hanford Management Contract (PHMC) facilities, that are not the direct responsibility of the facility manager (e.g., a site-wide fire department). Facility S/RIDs contain standards/requirements applicable to a specific facility that are the direct responsibility of the facility manager. S/RlDs are prepared by those responsible for managing the operation of facilities or the conduct of activities that present a potential threat to the health and safety of workers, public, or the environment, including: Hazard Category 1 and 2 nuclear facilities and activities, as defined in DOE 5480.23. Selected Hazard Category 3 nuclear, and Low Hazard non-nuclear facilities and activities, as agreed upon by RL. The Postirradiation Testing Laboratory (PTL) S/RID contains standards/ requirements that are necessary for safe operation of the PTL facility, and other building/areas that are the direct

  8. Simulation of a microgrid

    Science.gov (United States)

    Dulǎu, Lucian Ioan

    2015-12-01

    This paper describes the simulation of a microgrid system with storage technologies. The microgrid comprises 6 distributed generators (DGs), 3 loads and a 150 kW storage unit. The installed capacity of the generators is 1100 kW, while the total load demand is 900 kW. The simulation is performed by using a SCADA software, considering the power generation costs, the loads demand and the system's power losses. The generators access the system in order of their power generation cost. The simulation is performed for the entire day.

  9. Value and Technology Assessment to Enhance the Business Case for the CERTS Microgrid

    Energy Technology Data Exchange (ETDEWEB)

    Lasseter, Robert; Eto, Joe

    2010-05-15

    The CERTS Microgrid concept is an advanced approach for enabling integration of, in principle, an unlimited quantity of distributed energy resources into the electricity grid. A key feature of a microgrid, is its ability, during a utility grid disturbance, to separate and isolate itself from the utility seamlessly with no disruption to the loads within the microgrid (including no reduction in power quality). Then, when the utility grid returns to normal, the microgrid automatically resynchronizes and reconnects itself to the grid, in an equally seamless fashion. What is unique about the CERTS Microgrid is that it can provide this technically challenging functionality without extensive (i.e., expensive) custom engineering. In addition, the design of the CERTS Microgrid also provides high system reliability and great flexibility in the placement of distributed generation within the microgrid. The CERTS Microgrid offers these functionalities at much lower costs than traditional approaches by incorporating peer-to-peer and plug-and-play concepts for each component within the Microgrid. The predecessor to the current project involved the construction of and completion of initial testing using the world's first, full-scale, inverter-based, distributed generation test bed. The project demonstrated three advanced techniques, collectively referred to as the CERTS Microgrid concept, which collectively significantly reduce the level of custom field engineering needed to operate microgrids consisting of small generating sources. The techniques are: (1) a method for effecting automatic and seamless transitions between grid-connected and islanded modes of operation; (2) an approach to electrical protection within the microgrid that does not depend on high fault currents; and (3) a method for microgrid control that achieves voltage and frequency stability under both grid and islanded conditions without requiring high-speed communications. The work conducted in this phase of

  10. Adaptive Micro-Grid Operation Based on IEC 61850

    Directory of Open Access Journals (Sweden)

    Wei Deng

    2015-05-01

    Full Text Available Automatically identifying the new equipment after its integration and adjusting operation strategy to realize “plug and play” functionality are becoming essential for micro-grid operations. In order to improve and perfect the micro-grid “plug and play” function with the increased amount of equipment with different information protocols and more diverse system applications, this paper presents a solution for adaptive micro-grid operation based on IEC 61850, and proposes the design and specific implementation methods of micro-grid “plug and play” function and system operation mode conversion in detail, by using the established IEC 61850 information model of a micro-grid. Actual operation tests based on the developed IED and micro-grid test platform are performed to verify the feasibility and validity of the proposed solution. The tests results show that the solution can automatically identify the IEC 61850 information model of equipment after its integration, intelligently adjust the operation strategies to adapt to new system states and achieves a reliable system operation mode conversion.

  11. The CERTS microgrid and the future of the macrogrid

    Energy Technology Data Exchange (ETDEWEB)

    Marnay, Chris; Bailey, Owen C.

    2004-06-01

    The blackouts of summer 2003 underscored the dependence of western economies on reliable supply of electricity with tight tolerances of quality. While demand for electricity continues to grow, expansion of the traditional electricity supply system is constrained and is unlikely to keep pace with the growing thirst western economies have for electricity. Furthermore, no compelling case has been made that perpetual improvement in the overall power quality and reliability (PQR) delivered is possible or desirable. An alternative path to providing for sensitive loads is to provide for generation close to them. This would alleviate the pressure for endless improvement in grid PQR and might allow the establishment of a sounder economically based level of universal grid service. Providing for loads by means of local power generation is becoming increasingly competitive with central station generation for a number of reasons, four key ones being non-technical constraints on expansion of the grid, improvements in small scale technologies, opportunities for CHP application, and the ubiquitous nature of sensitive loads in advanced economies. Along with these new technologies, concepts for operating them partially under local control in microgrids are emerging, the CERTS Microgrid being one example. It has been demonstrated in simulation, and a laboratory test of a three microturbine system is planned for early 2005, to be followed by a field demonstration. A systemic energy analysis of a southern California naval base building demonstrates a current economic on-site power opportunity.

  12. 21 CFR 640.67 - Laboratory tests.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 7 2010-04-01 2010-04-01 false Laboratory tests. 640.67 Section 640.67 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) BIOLOGICS ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Source Plasma § 640.67 Laboratory tests. Each unit...

  13. A multiagent system for autonomous operation of islanded microgrids based on a power market environment

    Energy Technology Data Exchange (ETDEWEB)

    Kim, H.-M. [Department of Electrical Engineering, University of Incheon/12-1, Sondo-dong, Yeonsu-gu, Incheon, 406-840 (Korea, Republic of); Kinoshita, T. [Graduate School of Information Science, Tohoku University/2-1-1, Katahira, Aoba-ku, Sendai, 980-8577 (Japan); Shin, M.-Ch. [School of Information and Communication Engineering, Sungkyunkwan University/300, Cheoncheon-dong, Jangan-gu, Suwon, Gyeonggi-do, 440-746 (Korea, Republic of)

    2010-12-15

    One of the most important requirements of microgrid operation is to maintain a constant frequency such as 50 Hz or 60 Hz, which is closely related to a power balance between supply and demand. In general, microgrids are connected to power grids and surplus/shortage power of microgrids is traded with power grids. Since islanded microgrids are isolated from any power grids, the decrease in generation or load-shedding can be used to maintain the frequency when a power imbalance between supply and demand occurs. The power imbalance restricts the electricity use of consumers in the case of supply shortage and the power supply of suppliers in the case of supply surplus. Therefore, the islanded microgrid should be operated to reduce power imbalance conditions. Meanwhile, the microgrid is a small-scale power system and the employment of skillful operators for effective operation of its components requires high costs. Therefore, automatic operation of the components is effective realistically. In addition, the components are distributed in the microgrid and their operation should consider their owners' profits. For these reasons, a multiagent system application can be a good alternative for microgrid operation. In this paper, we present a multiagent system for autonomous operation of the islanded microgrid on a power market environment. The proposed multiagent system is designed based on a cooperative operation scheme. We show the functionality and the feasibility of the proposed multiagent system through several tests. (authors)

  14. A Multiagent System for Autonomous Operation of Islanded Microgrids Based on a Power Market Environment

    Directory of Open Access Journals (Sweden)

    Myong-Chul Shin

    2010-12-01

    Full Text Available One of the most important requirements of microgrid operation is to maintain a constant frequency such as 50 Hz or 60 Hz, which is closely related to a power balance between supply and demand. In general, microgrids are connected to power grids and surplus/shortage power of microgrids is traded with power grids. Since islanded microgrids are isolated from any power grids, the decrease in generation or load-shedding can be used to maintain the frequency when a power imbalance between supply and demand occurs. The power imbalance restricts the electricity use of consumers in the case of supply shortage and the power supply of suppliers in the case of supply surplus. Therefore, the islanded microgrid should be operated to reduce power imbalance conditions. Meanwhile, the microgrid is a small-scale power system and the employment of skillful operators for effective operation of its components requires high costs. Therefore, automatic operation of the components is effective realistically. In addition, the components are distributed in the microgrid and their operation should consider their owners’ profits. For these reasons, a multiagent system application can be a good alternative for microgrid operation. In this paper, we present a multiagent system for autonomous operation of the islanded microgrid on a power market environment. The proposed multiagent system is designed based on a cooperative operation scheme. We show the functionality and the feasibility of the proposed multiagent system through several tests.

  15. How Reliable Is Laboratory Testing?

    Science.gov (United States)

    Advertisement Proceeds from website advertising help sustain Lab Tests Online. AACC is a not-for-profit organization and does not endorse non-AACC products and services. Advertising & Sponsorship: Policy | Opportunities ...

  16. Hybrid Multi-Agent Control in Microgrids: Framework, Models and Implementations Based on IEC 61850

    Directory of Open Access Journals (Sweden)

    Xiaobo Dou

    2014-12-01

    Full Text Available Operation control is a vital and complex issue for microgrids. The objective of this paper is to explore the practical means of applying decentralized control by using a multi agent system in actual microgrids and devices. This paper presents a hierarchical control framework (HCF consisting of local reaction control (LRC level, local decision control (LDC level, horizontal cooperation control (HCC level and vertical cooperation control (VCC level to meet different control requirements of a microgrid. Then, a hybrid multi-agent control model (HAM is proposed to implement HCF, and the properties, functionalities and operating rules of HAM are described. Furthermore, the paper elaborates on the implementation of HAM based on the IEC 61850 Standard, and proposes some new implementation methods, such as extended information models of IEC 61850 with agent communication language and bidirectional interaction mechanism of generic object oriented substation event (GOOSE communication. A hardware design and software system are proposed and the results of simulation and laboratory tests verify the effectiveness of the proposed strategies, models and implementations.

  17. Laboratory testing for platelet function disorders.

    Science.gov (United States)

    Israels, S J

    2015-05-01

    Platelet function testing is both complex and labor intensive. A stepwise approach to the evaluation of patients with suspected platelet disorders will optimize the use of laboratory resources, beginning with an appropriate clinical evaluation to determine whether the bleeding is consistent with a defect of primary hemostasis. Bleeding assessment tools, evaluation of platelet counts, and review of peripheral blood cell morphology can aid the initial assessment. For patients requiring further laboratory testing, platelet aggregometry, secretion assays, and von Willebrand factor assays are the most useful next steps and will direct further specialized testing including flow cytometry, electron microscopy, and molecular diagnostics. Guidelines and recommendations for standardizing platelet function testing, with a particular focus on light transmission aggregometry, are available and can provide a template for clinical laboratories in establishing procedures that will optimize diagnosis and assure quality results. This review outlines an approach to platelet function testing and reviews testing methods available to clinical laboratories.

  18. System and method for controlling microgrid

    Science.gov (United States)

    Bose, Sumit; Achilles, Alfredo Sebastian; Liu, Yan; Ahmed, Emad Ezzat; Garces, Luis Jose

    2011-07-19

    A system for controlling a microgrid includes microgrid assets and a tieline for coupling the microgrid to a bulk grid; and a tieline controller coupled to the tieline. At least one of the microgrid assets comprises a different type of asset than another one of the microgrid assets. The tieline controller is configured for providing tieline control signals to adjust active and reactive power in respective microgrid assets in response to commands from the bulk grid operating entity, microgrid system conditions, bulk grid conditions, or combinations thereof.

  19. Harmonic mitigation in islanded microgrids by inverter-interfaced distributed energy resource

    Energy Technology Data Exchange (ETDEWEB)

    Xiongfei Wang

    2012-10-15

    primary droop controllers integrated with virtual output impedance loops and the secondary controllers enabled by the low-bandwidth communication. With the chosen control options of DER inverters, the circulating current characteristics in the droop-controlled parallel three-phase DER inverters are analysed. It is found that the circulating current not only consists of the Positive-Sequence Circulating Current (PSCC) but also contains the Negative-Sequence Circulating Current (NSCC) even when feeding linear balanced loads. It is shown that the presence of the NSCC deteriorates the current quality of inverters and results in unbalanced voltage distortion at certain buses of an islanded microgrid. In order to reduce the NSCC, an improved virtual output impedance loop is proposed, where a negative-sequence virtual resistance is introduced based on the detection of the negative-sequence output current. Moreover, to adapt to the variation of unbalanced loads, a dynamically-tuned negative-sequence resistance is developed. Thus, an autonomous NSCC control that is more suitable for the scattered DER units is achieved and validated via a series of laboratory tests. Under the built islanded microgrid, the control methods of DER inverters for active harmonic conditioning are investigated. Two autonomous harmonic current filtering and resonance damping approaches, i.e. the Resistive-Active Power Filter (R-APF)-based method and the virtual output resistance scheme, are evaluated. It has been found that the large grid-side inductances of DER inverters may lead to either underdamped or aggravated harmonic voltages in the islanded microgrid. To address such a challenge, a Variable Harmonic Impedance (VHI) concept is proposed, where positive resistances and negative inductances are synthesized at the dominant harmonic frequencies. Two case studies, including the single grid-interactive DER inverter and the parallel DER inverters, are carried out. Simulation and laboratory test results are

  20. Grid Modernization Laboratory Consortium - Testing and Verification

    Energy Technology Data Exchange (ETDEWEB)

    Kroposki, Benjamin; Skare, Paul; Pratt, Rob; Kim, Tom; Ellis, Abraham

    2017-05-11

    This paper highlights some of the unique testing capabilities and projects being performed at several national laboratories as part of the U. S. Department of Energy Grid Modernization Laboratory Consortium. As part of this effort, the Grid Modernization Laboratory Consortium Testing Network isbeing developed to accelerate grid modernization by enablingaccess to a comprehensive testing infrastructure and creating a repository of validated models and simulation tools that will be publicly available. This work is key to accelerating thedevelopment, validation, standardization, adoption, and deployment of new grid technologies to help meet U. S. energy goals.

  1. 10 CFR 431.18 - Testing laboratories.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Testing laboratories. 431.18 Section 431.18 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL AND INDUSTRIAL... supplements NIST Handbook 150, National Voluntary Laboratory Accreditation Program Procedures and...

  2. Renewable Microgrid STEM Education & Colonias Outreach Program

    Energy Technology Data Exchange (ETDEWEB)

    None, None

    2015-04-01

    To provide Science, Technology, Engineering, and Math (STEM) outreach and education to secondary students to encourage them to select science and engineering as a career by providing an engineering-based problem-solving experience involving renewable energy systems such as photovoltaic (PV) panels or wind turbines. All public and private schools, community colleges, and vocational training programs would be eligible for participation. The Power Microgrids High School Engineering Experience used renewable energy systems (PV and wind) to provide a design capstone experience to secondary students. The objective for each student team was to design a microgrid for the student’s school using renewable energy sources under cost, schedule, performance, and risk constraints. The students then implemented their designs in a laboratory environment to evaluate the completeness of the proposed design, which is a unique experience even for undergraduate college students. This application-based program was marketed to secondary schools in the 28th Congressional District through the Texas Education Agency’s (TEA) Regional Service Centers. Upon application, TEES identified regionally available engineers to act as mentors and supervisors for the projects. Existing curriculum was modified to include microgrid and additional renewable technologies and was made available to the schools.

  3. LWIR Microgrid Polarimeter for Remote Sensing Studies

    Science.gov (United States)

    2010-02-28

    Polarimeter for Remote Sensing Studies 5b. GRANT NUMBER FA9550-08-1-0295 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) 5d. PROJECT NUMBER 1. Scott Tyo 5e. TASK...and tested at the University of Arizona, and preliminary images are shown in this final report. 15. SUBJECT TERMS Remote Sensing , polarimetry 16...7.0 LWIR Microgrid Polarimeter for Remote Sensing Studies J. Scott Tyo College of Optical Sciences University of Arizona Tucson, AZ, 85721 tyo

  4. Stokes image reconstruction for two-color microgrid polarization imaging systems.

    Science.gov (United States)

    Lemaster, Daniel A

    2011-07-18

    The Air Force Research Laboratory has developed a new microgrid polarization imaging system capable of simultaneously reconstructing linear Stokes parameter images in two colors on a single focal plane array. In this paper, an effective method for extracting Stokes images is presented for this type of camera system. It is also shown that correlations between the color bands can be exploited to significantly increase overall spatial resolution. Test data is used to show the advantages of this approach over bilinear interpolation. The bounds (in terms of available reconstruction bandwidth) on image resolution are also provided.

  5. Microgrids and Heterogeneous Power Quality and Reliability

    Energy Technology Data Exchange (ETDEWEB)

    LaCommare, Kristina; Marnay, Chris

    2007-10-01

    This paper describes two stylized alternative visions of how the power system might evolve to meet future requirements for the high quality electricity service that modern digital economies demand, a supergrids paradigm and a dispersed paradigm. Some of the economics of the dispersed vision are explored, and perspectives are presented on both the choice of homogeneous universal power quality upstream in the electricity supply chain and on the extremely heterogeneous requirements of end-use loads. It is argued that meeting the demanding requirements of sensitive loads by local provision of high quality power may be more cost effective than increasing the quality of universal homogeneous supply upstream in the legacy grid. Finally, the potential role of microgrids in delivering heterogeneous power quality is demonstrated by reference to two ongoing microgrid tests in the U.S. and Japan.

  6. Fatigue Sensor Evaluation Program Laboratory Test Report.

    Science.gov (United States)

    1975-10-01

    Evaluation Program - laboratory Test Report, " by John Y. Kaufman, Design Engineer, and it was prepared for publication by Sue Bardsley, Technical Aid ...fatigue sensor as an aid to this purpose. The laboratory test effort was based on collection of data from six types of tests and thirty-three...34 ’: « •IIIS ......... li : « rtrtintr : •* M» c f M i H ::::::;:• ;:« ...j . .... ..:. •f’ ::.::::: ^::|:::: n» VH ft;; ** ViH ! * 1 - •• •-•• ; i

  7. Multidimensional optimal droop control for wind resources in DC microgrids

    Science.gov (United States)

    Bunker, Kaitlyn J.

    Two important and upcoming technologies, microgrids and electricity generation from wind resources, are increasingly being combined. Various control strategies can be implemented, and droop control provides a simple option without requiring communication between microgrid components. Eliminating the single source of potential failure around the communication system is especially important in remote, islanded microgrids, which are considered in this work. However, traditional droop control does not allow the microgrid to utilize much of the power available from the wind. This dissertation presents a novel droop control strategy, which implements a droop surface in higher dimension than the traditional strategy. The droop control relationship then depends on two variables: the dc microgrid bus voltage, and the wind speed at the current time. An approach for optimizing this droop control surface in order to meet a given objective, for example utilizing all of the power available from a wind resource, is proposed and demonstrated. Various cases are used to test the proposed optimal high dimension droop control method, and demonstrate its function. First, the use of linear multidimensional droop control without optimization is demonstrated through simulation. Next, an optimal high dimension droop control surface is implemented with a simple dc microgrid containing two sources and one load. Various cases for changing load and wind speed are investigated using simulation and hardware-in-the-loop techniques. Optimal multidimensional droop control is demonstrated with a wind resource in a full dc microgrid example, containing an energy storage device as well as multiple sources and loads. Finally, the optimal high dimension droop control method is applied with a solar resource, and using a load model developed for a military patrol base application. The operation of the proposed control is again investigated using simulation and hardware-in-the-loop techniques.

  8. SMES application for frequency control during islanded microgrid operation

    Science.gov (United States)

    Kim, A.-Rong; Kim, Gyeong-Hun; Heo, Serim; Park, Minwon; Yu, In-Keun; Kim, Hak-Man

    2013-01-01

    This paper analyzes the operating characteristics of a superconducting magnetic energy storage (SMES) for the frequency control of an islanded microgrid operation. In the grid-connected mode of a microgrid, an imbalance between power supply and demand is solved by a power trade with the upstream power grid. The difference in the islanded mode is a critical problem because the microgrid is isolated from any power grid. For this reason, the frequency control during islanded microgrid operation is a challenging issue. A test microgrid in this paper consisted of a wind power generator, a PV generation system, a diesel generator and a load to test the feasibility of the SMES for controlling frequency during islanded operation as well as the transient state varying from the grid-connected mode to the islanded mode. The results show that the SMES contributes well for frequency control in the islanded operation. In addition, a dual and a single magnet type of SMES have been compared to demonstrate the control performance. The dual magnet has the same energy capacity as the single magnet, but there are two superconducting coils and each coil has half inductance of the single magnet. The effectiveness of the SMES application with the simulation results is discussed in detail.

  9. [Laboratory tests for parasitic diseases in Israel].

    Science.gov (United States)

    Marva, Esther; Grossman, Tamar

    2010-09-01

    Microscopic examination is still considered the gold standard for the diagnosis of parasitic diseases. In many clinical laboratories in hospitals and in health maintenance organizations ("Kupot Holim"), an excellent microscopic identification of parasites is performed. Microscopic examinations using wet mount preparations are performed for the detection of protozoan trophozoites and helmintic ova or larvae. Specific concentration techniques, including flotation and sedimentation procedures are further performed for the diagnosis of parasitic diseases. However, microscopic examinations are time-consuming, non-sensitive and not always reliable. Furthermore, the diagnosis of certain infections is not always possible by searching for the parasites in host tissues or excreta since risky invasive techniques might be necessary to locate the parasites. Detection of antibodies can be very useful as an indication for infection with a specific parasite, especially in individuals with no exposure to the parasite prior to recent travel in a disease-endemic area. In addition to serology, there are other tests of high sensitivity which can be integrated with microscopy, such as antigen detection in stool and blood samples as well as the use of other molecular diagnosis methods. There are two main laboratories in Israel where parasitic diagnosis is available by integration of microscopy, serology, antigen detection and molecular methods: The Reference Laboratory for Parasitology in Jerusalem at the Central Laboratories of the Ministry of Health (MOH) and the Laboratory of Parasitology at Soroka University Medical Center, Beer Sheva (SOR). There are also two special diagnostic units, one responsible for the identification of toxopLasma: Reference Laboratory for Toxoplasmosis, Public Health Laboratory, Ministry of Health, Tel Aviv (Tox), and the other for the identification of Leishmaniasis: Kuvin Center, Faculty of Medicine, Hebrew University of Jerusalem (Kuv). This article

  10. Optimal Bidding Strategy for Renewable Microgrid with Active Network Management

    Directory of Open Access Journals (Sweden)

    Seung Wan Kim

    2016-01-01

    Full Text Available Active Network Management (ANM enables a microgrid to optimally dispatch the active/reactive power of its Renewable Distributed Generation (RDG and Battery Energy Storage System (BESS units in real time. Thus, a microgrid with high penetration of RDGs can handle their uncertainties and variabilities to achieve the stable operation using ANM. However, the actual power flow in the line connecting the main grid and microgrid may deviate significantly from the day-ahead bids if the bids are determined without consideration of the real-time adjustment through ANM, which will lead to a substantial imbalance cost. Therefore, this study proposes a formulation for obtaining an optimal bidding which reflects the change of power flow in the connecting line by real-time adjustment using ANM. The proposed formulation maximizes the expected profit of the microgrid considering various network and physical constraints. The effectiveness of the proposed bidding strategy is verified through the simulations with a 33-bus test microgrid. The simulation results show that the proposed bidding strategy improves the expected operating profit by reducing the imbalance cost to a greater degree compared to the basic bidding strategy without consideration of ANM.

  11. Power Electronics for Microgrids

    DEFF Research Database (Denmark)

    Dragicevic, Tomislav; Blaabjerg, Frede

    2016-01-01

    A microgrid (MG) is a stand-alone or grid-connected hybrid renewable system that uses distributed renewable and nonrenewable energy sources and energy storage systems (ESSs) to supply power to local loads. The system is ordinarily based on power electronics, with interface converters allowing...... a continuous supply of power in the presence of variable RES production. This chapter describes some specific features of DC MGs in terms of power architecture, control, and protection. It also reviews several uncommon power electronic interfaces. Regarding control, operation without critical communication...... are explained in this chapter. The chapter concludes with a review of power electronic intensive protection solutions for DC MGs....

  12. 7 CFR 75.43 - Laboratory testing.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Laboratory testing. 75.43 Section 75.43 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Standards... AND CERTIFICATION OF QUALITY OF AGRICULTURAL AND VEGETABLE SEEDS Fees and Charges § 75.43...

  13. Advanced Materials Laboratory User Test Planning Guide

    Science.gov (United States)

    Orndoff, Evelyne

    2012-01-01

    Test process, milestones and inputs are unknowns to first-time users of the Advanced Materials Laboratory. The User Test Planning Guide aids in establishing expectations for both NASA and non-NASA facility customers. The potential audience for this guide includes both internal and commercial spaceflight hardware/software developers. It is intended to assist their test engineering personnel in test planning and execution. Material covered includes a roadmap of the test process, roles and responsibilities of facility and user, major milestones, facility capabilities, and inputs required by the facility. Samples of deliverables, test article interfaces, and inputs necessary to define test scope, cost, and schedule are included as an appendix to the guide.

  14. Multi-Agent System-Based Microgrid Operation Strategy for Demand Response

    Directory of Open Access Journals (Sweden)

    Hee-Jun Cha

    2015-12-01

    Full Text Available The microgrid and demand response (DR are important technologies for future power grids. Among the variety of microgrid operations, the multi-agent system (MAS has attracted considerable attention. In a microgrid with MAS, the agents installed on the microgrid components operate optimally by communicating with each other. This paper proposes an operation algorithm for the individual agents of a test microgrid that consists of a battery energy storage system (BESS and an intelligent load. A microgrid central controller to manage the microgrid can exchange information with each agent. The BESS agent performs scheduling for maximum benefit in response to the electricity price and BESS state of charge (SOC through a fuzzy system. The intelligent load agent assumes that the industrial load performs scheduling for maximum benefit by calculating the hourly production cost. The agent operation algorithm includes a scheduling algorithm using day-ahead pricing in the DR program and a real-time operation algorithm for emergency situations using emergency demand response (EDR. The proposed algorithm and operation strategy were implemented both by a hardware-in-the-loop simulation test using OPAL-RT and an actual hardware test by connecting a new distribution simulator.

  15. Lessons Learned from Microgrid Demonstrations Worldwide

    Energy Technology Data Exchange (ETDEWEB)

    Marnay, Chris [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Zhou, Nan [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Qu, Min [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Romankiewicz, John [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2012-01-31

    The survey leads to policy recommendations for starting a microgrid demonstration program and overall development of microgrid and distributed energy. Additionally, specific recommendations have been made for China specifically.

  16. Iowa Central Quality Fuel Testing Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Heach, Don; Bidieman, Julaine

    2013-09-30

    The objective of this project is to finalize the creation of an independent quality fuel testing laboratory on the campus of Iowa Central Community College in Fort Dodge, Iowa that shall provide the exploding biofuels industry a timely and cost-effective centrally located laboratory to complete all state and federal fuel and related tests that are required. The recipient shall work with various state regulatory agencies, biofuel companies and state and national industry associations to ensure that training and testing needs of their members and American consumers are met. The recipient shall work with the Iowa Department of Ag and Land Stewardship on the development of an Iowa Biofuel Quality Standard along with the Development of a standard that can be used throughout industry.

  17. Extracting laboratory test information from biomedical text

    Directory of Open Access Journals (Sweden)

    Yanna Shen Kang

    2013-01-01

    Full Text Available Background: No previous study reported the efficacy of current natural language processing (NLP methods for extracting laboratory test information from narrative documents. This study investigates the pathology informatics question of how accurately such information can be extracted from text with the current tools and techniques, especially machine learning and symbolic NLP methods. The study data came from a text corpus maintained by the U.S. Food and Drug Administration, containing a rich set of information on laboratory tests and test devices. Methods: The authors developed a symbolic information extraction (SIE system to extract device and test specific information about four types of laboratory test entities: Specimens, analytes, units of measures and detection limits. They compared the performance of SIE and three prominent machine learning based NLP systems, LingPipe, GATE and BANNER, each implementing a distinct supervised machine learning method, hidden Markov models, support vector machines and conditional random fields, respectively. Results: Machine learning systems recognized laboratory test entities with moderately high recall, but low precision rates. Their recall rates were relatively higher when the number of distinct entity values (e.g., the spectrum of specimens was very limited or when lexical morphology of the entity was distinctive (as in units of measures, yet SIE outperformed them with statistically significant margins on extracting specimen, analyte and detection limit information in both precision and F-measure. Its high recall performance was statistically significant on analyte information extraction. Conclusions: Despite its shortcomings against machine learning methods, a well-tailored symbolic system may better discern relevancy among a pile of information of the same type and may outperform a machine learning system by tapping into lexically non-local contextual information such as the document structure.

  18. Performance testing of UK personal dosimetry laboratories

    CERN Document Server

    Marshall, T O

    1985-01-01

    The proposed Ionising Radiations Regulations will require all UK personal dosimetry laboratories that monitor classified personnel to be approved for personal dosimetry by the Health and Safety Executive. It is suggested that these approvals should be based on general and supplementary criteria published by the British Calibration Service (BCS) for laboratory approval for the provision of personal dosimetry services. These criteria specify certain qualitative requirements and also indicate the need for regular tests of performance to be carried out to ensure constancy of dosimetric standards. This report concerns the latter. The status of the BCS criteria is discussed and the need for additional documents to cover new techniques and some modifications to existing documents is indicated. A means is described by which the technical performance of laboratories, concerned with personal monitoring for external radiations, can be assessed, both initially and ongoing. The costs to establish the scheme and operate it...

  19. Improving Distribution Resiliency with Microgrids and State and Parameter Estimation

    Energy Technology Data Exchange (ETDEWEB)

    Tuffner, Francis K. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Williams, Tess L. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Schneider, Kevin P. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Elizondo, Marcelo A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Sun, Yannan [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Liu, Chen-Ching [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Xu, Yin [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Gourisetti, Sri Nikhil Gup [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2015-09-30

    Modern society relies on low-cost reliable electrical power, both to maintain industry, as well as provide basic social services to the populace. When major disturbances occur, such as Hurricane Katrina or Hurricane Sandy, the nation’s electrical infrastructure can experience significant outages. To help prevent the spread of these outages, as well as facilitating faster restoration after an outage, various aspects of improving the resiliency of the power system are needed. Two such approaches are breaking the system into smaller microgrid sections, and to have improved insight into the operations to detect failures or mis-operations before they become critical. Breaking the system into smaller sections of microgrid islands, power can be maintained in smaller areas where distribution generation and energy storage resources are still available, but bulk power generation is no longer connected. Additionally, microgrid systems can maintain service to local pockets of customers when there has been extensive damage to the local distribution system. However, microgrids are grid connected a majority of the time and implementing and operating a microgrid is much different than when islanded. This report discusses work conducted by the Pacific Northwest National Laboratory that developed improvements for simulation tools to capture the characteristics of microgrids and how they can be used to develop new operational strategies. These operational strategies reduce the cost of microgrid operation and increase the reliability and resilience of the nation’s electricity infrastructure. In addition to the ability to break the system into microgrids, improved observability into the state of the distribution grid can make the power system more resilient. State estimation on the transmission system already provides great insight into grid operations and detecting abnormal conditions by leveraging existing measurements. These transmission-level approaches are expanded to using

  20. Microgrid cyber security reference architecture.

    Energy Technology Data Exchange (ETDEWEB)

    Veitch, Cynthia K.; Henry, Jordan M.; Richardson, Bryan T.; Hart, Derek H.

    2013-07-01

    This document describes a microgrid cyber security reference architecture. First, we present a high-level concept of operations for a microgrid, including operational modes, necessary power actors, and the communication protocols typically employed. We then describe our motivation for designing a secure microgrid; in particular, we provide general network and industrial control system (ICS)-speci c vulnerabilities, a threat model, information assurance compliance concerns, and design criteria for a microgrid control system network. Our design approach addresses these concerns by segmenting the microgrid control system network into enclaves, grouping enclaves into functional domains, and describing actor communication using data exchange attributes. We describe cyber actors that can help mitigate potential vulnerabilities, in addition to performance bene ts and vulnerability mitigation that may be realized using this reference architecture. To illustrate our design approach, we present a notional a microgrid control system network implementation, including types of communica- tion occurring on that network, example data exchange attributes for actors in the network, an example of how the network can be segmented to create enclaves and functional domains, and how cyber actors can be used to enforce network segmentation and provide the neces- sary level of security. Finally, we describe areas of focus for the further development of the reference architecture.

  1. Control of grid interactive AC microgrids

    DEFF Research Database (Denmark)

    Wang, Xiongfei; Guerrero, Josep M.; Chen, Zhe

    2010-01-01

    and reliability, becomes an attractive candidate for the configuration of future electrical power system. This paper gives a brief review of grid interactive ac microgrid configurations. Control methods for power electronics interfaced DER units in grid interactive ac microgrids are discussed. In addition......, microgrid controls and power management strategies are presented. Future trends of microgrid are discussed pointing out how this concept can be a key to achieve a more intelligent and flexible AC grid....

  2. Equivalent Simplification Method of Micro-Grid

    OpenAIRE

    Cai Changchun; Cao Xiangqin

    2013-01-01

    The paper concentrates on the equivalent simplification method for the micro-grid system connection into distributed network. The equivalent simplification method proposed for interaction study between micro-grid and distributed network. Micro-grid network, composite load, gas turbine synchronous generation, wind generation are equivalent simplification and parallel connect into the point of common coupling. A micro-grid system is built and three phase and single phase grounded faults are per...

  3. Boston Community Energy Study - Zonal Analysis for Urban Microgrids

    Science.gov (United States)

    2016-04-05

    determine the cost-optimal and CO2-optimal scenarios which incorporated the energy demand, utility prices , local weather resources, and equipment capital ...45%, respectively. The range and capital expenditure was between $1 million and $5 million with an average of $2.8 million spent on capital assets ...developed by Lawrence Berkeley National Laboratory, with whom the MIT Lincoln Laboratory is now collaborating on microgrid modeling work. Using the

  4. Laboratory testing in disseminated intravascular coagulation.

    Science.gov (United States)

    Favaloro, Emmanuel J

    2010-06-01

    The diagnosis of disseminated intravascular coagulation (DIC) relies on clinical signs and symptoms, identification of the underlying disease, the results of laboratory testing, and differentiation from other pathologies. The clinical features mainly depend on the underlying cause of the DIC. The laboratory diagnosis of DIC uses a combination of tests because no single test result alone can firmly establish or rule out the diagnosis. Global tests of hemostasis may initially provide evidence of coagulation activation and later in the process provide evidence of consumption of coagulation factors, but their individual diagnostic efficiency is limited. Fibrinolytic markers, in particular D-dimer, are reflective of activation of both coagulation and fibrinolysis, so that a normal finding can be useful for ruling-out DIC. Decreased levels of the natural anticoagulants (in particular, antithrombin and protein C) are frequently observed in patients with DIC, but their measurement is not normally incorporated into standard diagnostic algorithms. New tests are being explored for utility in DIC, and some additional tests may be useful on a case-by-case basis, depending on the proposed cause of the DIC or their local availability. For example, clot waveform analysis is useful but currently limited to a single instrument. Also, procalcitonin is an inflammatory biomarker that may be useful within the context of septic DIC, and activated factor X clotting time is an emerging test of procoagulant phospholipids that also seems to hold promise in DIC.

  5. A Review of Power Electronics Based Microgrids

    DEFF Research Database (Denmark)

    Wang, Xiongfei; Guerrero, Josep M.; Blaabjerg, Frede

    2012-01-01

    of microgrid configurations is given. Then, possible structure options and control methods of DER units are presented, which is followed by the descriptions of system controls and power management strategies for AC microgrids. Finally, future trends of microgrids are discussed pointing out how this concept can...

  6. Mars Science Laboratory Rover System Thermal Test

    Science.gov (United States)

    Novak, Keith S.; Kempenaar, Joshua E.; Liu, Yuanming; Bhandari, Pradeep; Dudik, Brenda A.

    2012-01-01

    On November 26, 2011, NASA launched a large (900 kg) rover as part of the Mars Science Laboratory (MSL) mission to Mars. The MSL rover is scheduled to land on Mars on August 5, 2012. Prior to launch, the Rover was successfully operated in simulated mission extreme environments during a 16-day long Rover System Thermal Test (STT). This paper describes the MSL Rover STT, test planning, test execution, test results, thermal model correlation and flight predictions. The rover was tested in the JPL 25-Foot Diameter Space Simulator Facility at the Jet Propulsion Laboratory (JPL). The Rover operated in simulated Cruise (vacuum) and Mars Surface environments (8 Torr nitrogen gas) with mission extreme hot and cold boundary conditions. A Xenon lamp solar simulator was used to impose simulated solar loads on the rover during a bounding hot case and during a simulated Mars diurnal test case. All thermal hardware was exercised and performed nominally. The Rover Heat Rejection System, a liquid-phase fluid loop used to transport heat in and out of the electronics boxes inside the rover chassis, performed better than predicted. Steady state and transient data were collected to allow correlation of analytical thermal models. These thermal models were subsequently used to predict rover thermal performance for the MSL Gale Crater landing site. Models predict that critical hardware temperatures will be maintained within allowable flight limits over the entire 669 Sol surface mission.

  7. Design and Implementation of a Control Strategy for Microgrid Containing Renewable Energy Generations and Electric Vehicles

    Directory of Open Access Journals (Sweden)

    Mingchao Xia

    2013-01-01

    Full Text Available Large amount of such renewable energy generations as wind/photovoltaic generations directly connected to grid acting as distributed generations will cause control, protection, security, and safety problems. Microgrid, which has advantages in usage and control of distributed generations, is a promising approach to coordinate the conflict between distributed generations and the grid. Regarded as mobile power storages, batteries of electric vehicles can depress the fluctuation of power through the point of common coupling of microgrid. This paper presents a control strategy for microgrid containing renewable energy generations and electric vehicles. The control strategy uses current control for renewable energy generations under parallel-to-grid mode, and uses master-slave control under islanding mode. Simulations and laboratory experiments prove that the control strategy works well for microgrid containing renewable energy generations and electric vehicles and provides maximum power output of renewable energy and a stable and sustainable running under islanding mode.

  8. Voltage stability in low voltage microgrids in aspects of active and reactive power demand

    Directory of Open Access Journals (Sweden)

    Parol Mirosław

    2016-03-01

    Full Text Available Low voltage microgrids are autonomous subsystems, in which generation, storage and power and electrical energy consumption appear. In the paper the main attention has been paid to the voltage stability issue in low voltage microgrid for different variants of its operation. In the introduction a notion of microgrid has been presented, and also the issue of influence of active and reactive power balance on node voltage level has been described. Then description of voltage stability issue has been presented. The conditions of voltage stability and indicators used to determine voltage stability margin in the microgrid have been described. Description of the low voltage test microgrid, as well as research methodology along with definition of considered variants of its operation have been presented further. The results of exemplary calculations carried out for the daily changes in node load of the active and reactive power, i.e. the voltage and the voltage stability margin indexes in nodes have been presented. Furthermore, the changes of voltage stability margin indexes depending on the variant of the microgrid operation have been presented. Summary and formulation of conclusions related to the issue of voltage stability in microgrids have been included at the end of the paper.

  9. Test report :

    Energy Technology Data Exchange (ETDEWEB)

    Rose, David Martin; Schenkman, Benjamin L.; Borneo, Daniel R.

    2013-10-01

    The Department of Energy Office of Electricity (DOE/OE), Sandia National Laboratories (SNL) and the Base Camp Integration Lab (BCIL) partnered together to incorporate an energy storage system into a microgrid configured Forward Operating Base to reduce the fossil fuel consumption and to ultimately save lives. Energy storage vendors will be sending their systems to SNL Energy Storage Test Pad (ESTP) for functional testing and then to the BCIL for performance evaluation. The technologies that will be tested are electro-chemical energy storage systems comprising of lead acid, lithium-ion or zinc-bromide. Raytheon/KTech has developed an energy storage system that utilizes zinc-bromide flow batteries to save fuel on a military microgrid. This report contains the testing results and some limited analysis of performance of the Raytheon/KTech Zinc-Bromide Energy Storage System.

  10. Test report :

    Energy Technology Data Exchange (ETDEWEB)

    Rose, David Martin; Schenkman, Benjamin L.; Borneo, Daniel R.

    2013-08-01

    The Department of Energy Office of Electricity (DOE/OE), Sandia National Laboratory (SNL) and the Base Camp Integration Lab (BCIL) partnered together to incorporate an energy storage system into a microgrid configured Forward Operating Base to reduce the fossil fuel consumption and to ultimately save lives. Energy storage vendors have supplied their systems to SNL Energy Storage Test Pad (ESTP) for functional testing and a subset of these systems were selected for performance evaluation at the BCIL. The technologies tested were electro-chemical energy storage systems comprised of lead acid, lithium-ion or zinc-bromide. MILSPRAY Military Technologies has developed an energy storage system that utilizes lead acid batteries to save fuel on a military microgrid. This report contains the testing results and some limited assessment of the Milspray Scorpion Energy Storage Device.

  11. 19 CFR 151.71 - Laboratory testing for clean yield.

    Science.gov (United States)

    2010-04-01

    ... 19 Customs Duties 2 2010-04-01 2010-04-01 false Laboratory testing for clean yield. 151.71 Section... Laboratory testing for clean yield. (a) Test and report by Customs laboratory. The clean yield of all general samples taken in accordance with § 151.70 shall be determined by test in a Customs laboratory, unless...

  12. DTU PMU Laboratory Development - Testing and Validation

    DEFF Research Database (Denmark)

    Garcia-Valle, Rodrigo; Yang, Guang-Ya; Martin, Kenneth E.;

    2010-01-01

    This is a report of the results of phasor measurement unit (PMU) laboratory development and testing done at the Centre for Electric Technology (CET), Technical University of Denmark (DTU). Analysis of the PMU performance first required the development of tools to convert the DTU PMU data into IEEE...... standard, and the validation is done for the DTU-PMU via a validated commercial PMU. The commercial PMU has been tested from the authors' previous efforts, where the response can be expected to follow known patterns and provide confirmation about the test system to confirm the design and settings....... In a nutshell, having 2 PMUs that observe same signals provides validation of the operation and flags questionable results with more certainty. Moreover, the performance and accuracy of the DTU-PMU is tested acquiring good and precise results, when compared with a commercial phasor measurement device, PMU-1....

  13. Modular Energy Management System Applicable to Residential Microgrids

    DEFF Research Database (Denmark)

    Hernández, Adriana Carolina Luna; Aldana, Nelson Leonardo Diaz; Graells, Moises;

    2016-01-01

    In this paper, an energy management system is defined as a flexible architecture. This proposal can be applied to home and residential areas when they include generation units. The system has been integrated and tested in a grid-connected microgrid prototype, where optimal power generation profiles...

  14. Stochastic optimization of laboratory test workflow at metallurgical testing centers

    Directory of Open Access Journals (Sweden)

    F. Tošenovský

    2016-10-01

    Full Text Available The objective of the paper is to present a way to shorten the time required to perform laboratory tests of materials in metallurgy. The paper finds a relation between the time to perform a test of materials and the number of technicians carrying out the test. The relation can be used to optimize the number of technicians. The approach is based on probability theory, as the amount of material to be tested is unknown in advance, and uses powerful modelling techniques involving the generalized estimating equations.

  15. Laboratory tests of sludge-control additives

    Energy Technology Data Exchange (ETDEWEB)

    Tatnall, R.E. [MIC Associates, Inc., Chadds Ford, PA (United States)

    1996-07-01

    Laboratory {open_quotes}jar{close_quotes} tests compared eleven different fuel oil and diesel fuel sludge-control additives. Factors studied included (1) ability to disperse and prevent buildup of sludge deposits on surfaces, (2) ability to protect steel from corrosion, (3) ability to inhibit growth and proliferation of bacteria, and (4) ability to disperse water. Results varied greatly, and it was found that many commercial products do not do what they claim. It is concluded that fuel retailers should not believe manufacturers` claims for their additive products, but rather should test such products themselves to be sure that the benefits of treatment are real. A simplified form of the procedure used here is proposed as one way for dealers to do such testing.

  16. Laboratory rock mechanics testing manual. Public draft

    Energy Technology Data Exchange (ETDEWEB)

    Shuri, F S; Cooper, J D; Hamill, M L

    1981-10-01

    Standardized laboratory rock mechanics testing procedures have been prepared for use in the National Terminal Waste Storage Program. The procedures emphasize equipment performance specifications, documentation and reporting, and Quality Assurance acceptance criteria. Sufficient theoretical background is included to allow the user to perform the necessary data reduction. These procedures incorporate existing standards when possible, otherwise they represent the current state-of-the-art. Maximum flexibility in equipment design has been incorporated to allow use of this manual by existing groups and to encourage future improvements.

  17. Test plan for ISV laboratory-pyrolysis testing

    Energy Technology Data Exchange (ETDEWEB)

    McAtee, R.E.

    1991-09-01

    The objective of the laboratory-pyrolysis studies is to obtain information on the high temperature (< 1200{degree}C) degradation and alteration of organic chemicals and materials similar to those found in the Radioactive Waste Management Complex, Pit 9. This test plan describes experimental procedures, sampling and analysis strategy, sampling procedures, sample control, and document management. It addresses safety issues in the experimental apparatus and procedures, personal training, and hazardous waste disposal. Finally, it describes the data quality objectives using the EPA tiered approach to treatability studies to define where research/scoping tests fit into these studies and the EPA analytical levels required for the tests.

  18. Remotely accessible laboratory for MEMS testing

    Science.gov (United States)

    Sivakumar, Ganapathy; Mulsow, Matthew; Melinger, Aaron; Lacouture, Shelby; Dallas, Tim E.

    2010-02-01

    We report on the construction of a remotely accessible and interactive laboratory for testing microdevices (aka: MicroElectroMechancial Systems - MEMS). Enabling expanded utilization of microdevices for research, commercial, and educational purposes is very important for driving the creation of future MEMS devices and applications. Unfortunately, the relatively high costs associated with MEMS devices and testing infrastructure makes widespread access to the world of MEMS difficult. The creation of a virtual lab to control and actuate MEMS devices over the internet helps spread knowledge to a larger audience. A host laboratory has been established that contains a digital microscope, microdevices, controllers, and computers that can be logged into through the internet. The overall layout of the tele-operated MEMS laboratory system can be divided into two major parts: the server side and the client side. The server-side is present at Texas Tech University, and hosts a server machine that runs the Linux operating system and is used for interfacing the MEMS lab with the outside world via internet. The controls from the clients are transferred to the lab side through the server interface. The server interacts with the electronics required to drive the MEMS devices using a range of National Instruments hardware and LabView Virtual Instruments. An optical microscope (100 ×) with a CCD video camera is used to capture images of the operating MEMS. The server broadcasts the live video stream over the internet to the clients through the website. When the button is pressed on the website, the MEMS device responds and the video stream shows the movement in close to real time.

  19. Mars Science Laboratory Flight Software Internal Testing

    Science.gov (United States)

    Jones, Justin D.; Lam, Danny

    2011-01-01

    The Mars Science Laboratory (MSL) team is sending the rover, Curiosity, to Mars, and therefore is physically and technically complex. During my stay, I have assisted the MSL Flight Software (FSW) team in implementing functional test scripts to ensure that the FSW performs to the best of its abilities. There are a large number of FSW requirements that have been written up for implementation; however I have only been assigned a few sections of these requirements. There are many stages within testing; one of the early stages is FSW Internal Testing (FIT). The FIT team can accomplish this with simulation software and the MSL Test Automation Kit (MTAK). MTAK has the ability to integrate with the Software Simulation Equipment (SSE) and the Mission Processing and Control System (MPCS) software which makes it a powerful tool within the MSL FSW development process. The MSL team must ensure that the rover accomplishes all stages of the mission successfully. Due to the natural complexity of this project there is a strong emphasis on testing, as failure is not an option. The entire mission could be jeopardized if something is overlooked.

  20. Laboratory test surveillance following acute kidney injury.

    Directory of Open Access Journals (Sweden)

    Michael E Matheny

    Full Text Available BACKGROUND: Patients with hospitalized acute kidney injury (AKI are at increased risk for accelerated loss of kidney function, morbidity, and mortality. We sought to inform efforts at improving post-AKI outcomes by describing the receipt of renal-specific laboratory test surveillance among a large high-risk cohort. METHODS: We acquired clinical data from the Electronic health record (EHR of 5 Veterans Affairs (VA hospitals to identify patients hospitalized with AKI from January 1st, 2002 to December 31st, 2009, and followed these patients for 1 year or until death, enrollment in palliative care, or improvement in renal function to estimated GFR (eGFR ≥ 60 L/min/1.73 m(2. Using demographic data, administrative codes, and laboratory test data, we evaluated the receipt and timing of outpatient testing for serum concentrations of creatinine and any as well as quantitative proteinuria recommended for CKD risk stratification. Additionally, we reported the rate of phosphorus and parathyroid hormone (PTH monitoring recommended for chronic kidney disease (CKD patients. RESULTS: A total of 10,955 patients admitted with AKI were discharged with an eGFR<60 mL/min/1.73 m2. During outpatient follow-up at 90 and 365 days, respectively, creatinine was measured on 69% and 85% of patients, quantitative proteinuria was measured on 6% and 12% of patients, PTH or phosphorus was measured on 10% and 15% of patients. CONCLUSIONS: Measurement of creatinine was common among all patients following AKI. However, patients with AKI were infrequently monitored with assessments of quantitative proteinuria or mineral metabolism disorder, even for patients with baseline kidney disease.

  1. Laboratory test surveillance following acute kidney injury.

    Science.gov (United States)

    Matheny, Michael E; Peterson, Josh F; Eden, Svetlana K; Hung, Adriana M; Speroff, Theodore; Abdel-Kader, Khaled; Parr, Sharidan K; Ikizler, T Alp; Siew, Edward D

    2014-01-01

    Patients with hospitalized acute kidney injury (AKI) are at increased risk for accelerated loss of kidney function, morbidity, and mortality. We sought to inform efforts at improving post-AKI outcomes by describing the receipt of renal-specific laboratory test surveillance among a large high-risk cohort. We acquired clinical data from the Electronic health record (EHR) of 5 Veterans Affairs (VA) hospitals to identify patients hospitalized with AKI from January 1st, 2002 to December 31st, 2009, and followed these patients for 1 year or until death, enrollment in palliative care, or improvement in renal function to estimated GFR (eGFR) ≥ 60 L/min/1.73 m(2). Using demographic data, administrative codes, and laboratory test data, we evaluated the receipt and timing of outpatient testing for serum concentrations of creatinine and any as well as quantitative proteinuria recommended for CKD risk stratification. Additionally, we reported the rate of phosphorus and parathyroid hormone (PTH) monitoring recommended for chronic kidney disease (CKD) patients. A total of 10,955 patients admitted with AKI were discharged with an eGFR<60 mL/min/1.73 m2. During outpatient follow-up at 90 and 365 days, respectively, creatinine was measured on 69% and 85% of patients, quantitative proteinuria was measured on 6% and 12% of patients, PTH or phosphorus was measured on 10% and 15% of patients. Measurement of creatinine was common among all patients following AKI. However, patients with AKI were infrequently monitored with assessments of quantitative proteinuria or mineral metabolism disorder, even for patients with baseline kidney disease.

  2. 49 CFR 199.107 - Drug testing laboratory.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Drug testing laboratory. 199.107 Section 199.107... § 199.107 Drug testing laboratory. (a) Each operator shall use for the drug testing required by this part only drug testing laboratories certified by the Department of Health and Human Services under...

  3. A Micro-Grid Simulator Tool (SGridSim) using Effective Node-to-Node Complex Impedance (EN2NCI) Models

    Energy Technology Data Exchange (ETDEWEB)

    Udhay Ravishankar; Milos manic

    2013-08-01

    This paper presents a micro-grid simulator tool useful for implementing and testing multi-agent controllers (SGridSim). As a common engineering practice it is important to have a tool that simplifies the modeling of the salient features of a desired system. In electric micro-grids, these salient features are the voltage and power distributions within the micro-grid. Current simplified electric power grid simulator tools such as PowerWorld, PowerSim, Gridlab, etc, model only the power distribution features of a desired micro-grid. Other power grid simulators such as Simulink, Modelica, etc, use detailed modeling to accommodate the voltage distribution features. This paper presents a SGridSim micro-grid simulator tool that simplifies the modeling of both the voltage and power distribution features in a desired micro-grid. The SGridSim tool accomplishes this simplified modeling by using Effective Node-to-Node Complex Impedance (EN2NCI) models of components that typically make-up a micro-grid. The term EN2NCI models means that the impedance based components of a micro-grid are modeled as single impedances tied between their respective voltage nodes on the micro-grid. Hence the benefit of the presented SGridSim tool are 1) simulation of a micro-grid is performed strictly in the complex-domain; 2) faster simulation of a micro-grid by avoiding the simulation of detailed transients. An example micro-grid model was built using the SGridSim tool and tested to simulate both the voltage and power distribution features with a total absolute relative error of less than 6%.

  4. Energy and operation management of a microgrid using particle swarm optimization

    Science.gov (United States)

    Radosavljević, Jordan; Jevtić, Miroljub; Klimenta, Dardan

    2016-05-01

    This article presents an efficient algorithm based on particle swarm optimization (PSO) for energy and operation management (EOM) of a microgrid including different distributed generation units and energy storage devices. The proposed approach employs PSO to minimize the total energy and operating cost of the microgrid via optimal adjustment of the control variables of the EOM, while satisfying various operating constraints. Owing to the stochastic nature of energy produced from renewable sources, i.e. wind turbines and photovoltaic systems, as well as load uncertainties and market prices, a probabilistic approach in the EOM is introduced. The proposed method is examined and tested on a typical grid-connected microgrid including fuel cell, gas-fired microturbine, wind turbine, photovoltaic and energy storage devices. The obtained results prove the efficiency of the proposed approach to solve the EOM of the microgrids.

  5. High performance transparent conductor of graphene wrapped copper/nickel microgrids

    Science.gov (United States)

    Wu, Wei; Tassi, Nancy G.; Walls, Dennis J.; Zhang, Lei; Willner, Bruce

    2014-12-01

    A high performance, highly stable transparent conducting structure based on microscale copper/nickel grids wrapped with graphene is presented. Graphene is selectively deposited on the surfaces of the microgrids by atmospheric pressure chemical vapor deposition method. The optical transmittance of the copper/nickel microgrid sample is ˜80% over the visible and near-infrared spectra with a very small sheet resistance of ˜0.58 Ω/sq. After the high temperature deposition of graphene, the sample's transmittance increases to be ˜90% due to the line width reduction of the microgrids while the sheet resistance also increases to ˜5 Ω/sq. The graphene layer is deposited to keep the copper/nickel surfaces from being oxidized in the air. Both stability testing and composition spectra results confirm the long-term stability of the copper/nickel microgrids wrapped with graphene.

  6. 42 CFR 493.1403 - Condition: Laboratories performing moderate complexity testing; laboratory director.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Condition: Laboratories performing moderate complexity testing; laboratory director. 493.1403 Section 493.1403 Public Health CENTERS FOR MEDICARE... LABORATORY REQUIREMENTS Personnel for Nonwaived Testing Laboratories Performing Moderate Complexity...

  7. A Generalised Fault Protection Structure Proposed for Uni-grounded Low-Voltage AC Microgrids

    Science.gov (United States)

    Bui, Duong Minh; Chen, Shi-Lin; Lien, Keng-Yu; Jiang, Jheng-Lun

    2016-04-01

    This paper presents three main configurations of uni-grounded low-voltage AC microgrids. Transient situations of a uni-grounded low-voltage (LV) AC microgrid (MG) are simulated through various fault tests and operation transition tests between grid-connected and islanded modes. Based on transient simulation results, available fault protection methods are proposed for main and back-up protection of a uni-grounded AC microgrid. In addition, concept of a generalised fault protection structure of uni-grounded LVAC MGs is mentioned in the paper. As a result, main contributions of the paper are: (i) definition of different uni-grounded LVAC MG configurations; (ii) analysing transient responses of a uni-grounded LVAC microgrid through line-to-line faults, line-to-ground faults, three-phase faults and a microgrid operation transition test, (iii) proposing available fault protection methods for uni-grounded microgrids, such as: non-directional or directional overcurrent protection, under/over voltage protection, differential current protection, voltage-restrained overcurrent protection, and other fault protection principles not based on phase currents and voltages (e.g. total harmonic distortion detection of currents and voltages, using sequence components of current and voltage, 3I0 or 3V0 components), and (iv) developing a generalised fault protection structure with six individual protection zones to be suitable for different uni-grounded AC MG configurations.

  8. Value Streams in Microgrids: A literature Review

    Energy Technology Data Exchange (ETDEWEB)

    Stadler, Michael [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Center for Energy and Innovative Technologies (CET) (Austria); Cardoso, Gonçalo [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Mashayekh, Salman [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Forget, Thibault [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); MINES Paris Tech. (France); DeForest, Nicholas [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Agarwal, Ankit [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Univ. of California, Berkeley, CA (United States); Schönbein, Anna [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Univ. of Freiburg (Germany)

    2015-10-01

    Microgrids are an increasingly common component of the evolving electricity grids with the potential to improve local reliability, reduce costs, and increase penetration rates for distributed renewable generation. The additional complexity of microgrids often leads to increased investment costs, creating a barrier for widespread adoption. These costs may result directly from specific needs for islanding detection, protection systems and power quality assurance that would otherwise be avoided in simpler system configurations. However, microgrids also facilitate additional value streams that may make up for their increased costs and improve the economic viability of microgrid deployment. This paper analyses the literature currently available on research relevant to value streams occurring in microgrids that may contribute to offset the increased investment costs. A review on research related to specific microgrid requirements is also presented.

  9. Optimizing tuberculosis testing for basic laboratories.

    Science.gov (United States)

    Ramos, Eric; Schumacher, Samuel G; Siedner, Mark; Herrera, Beatriz; Quino, Willi; Alvarado, Jessica; Montoya, Rosario; Grandjean, Louis; Martin, Laura; Sherman, Jonathan M; Gilman, Robert H; Evans, Carlton A

    2010-10-01

    Optimal tuberculosis testing usually involves sputum centrifugation followed by broth culture. However, centrifuges are biohazardous and scarce in the resource-limited settings where most tuberculosis occurs. To optimize tuberculosis testing for these settings, centrifugation of 111 decontaminated sputum samples was compared with syringe-aspiration through polycarbonate membrane-filters that were then cultured in broth. To reduce the workload of repeated microscopic screening of broth cultures for tuberculosis growth, the colorimetric redox indicator 2,3-diphenyl-5-(2-thienyl) tetrazolium chloride was added to the broth, which enabled naked-eye detection of culture positivity. This combination of filtration and colorimetric growth-detection gave similar results to sputum centrifugation followed by culture microscopy regarding mean colony counts (43 versus 48; P = 0.6), contamination rates (0.9% versus 1.8%; P = 0.3), and sensitivity (94% versus 95%; P = 0.7), suggesting equivalency of the two methods. By obviating centrifugation and repeated microscopic screening of cultures, this approach may constitute a more appropriate technology for rapid and sensitive tuberculosis diagnosis in basic laboratories.

  10. 9 CFR 590.580 - Laboratory tests and analyses.

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 2 2010-01-01 2010-01-01 false Laboratory tests and analyses. 590.580... EGG PRODUCTS INSPECTION INSPECTION OF EGGS AND EGG PRODUCTS (EGG PRODUCTS INSPECTION ACT) Laboratory § 590.580 Laboratory tests and analyses. The official plant, at their expense, shall make tests...

  11. Microgrid Modeling and Simulation Study

    Science.gov (United States)

    2016-09-01

    bases must have a central power plant with possible opportunity for interconnection with a local utility grid and an operating load from hundreds of...Defense Technical Information Center database, National Science Foundation awards, IEEE Xplore digital library , ScienceDirect.com, Scientific.net, and...5 capability categories for tactical microgrids: Demand Management, Power Distribution, Source Management, Communications, and Smart Controls. In

  12. Energy manager design for microgrids

    Energy Technology Data Exchange (ETDEWEB)

    Firestone, Ryan; Marnay, Chris

    2005-01-01

    On-site energy production, known as distributed energy resources (DER), offers consumers many benefits, such as bill savings and predictability, improved system efficiency, improved reliability, control over power quality, and in many cases, greener electricity. Additionally, DER systems can benefit electric utilities by reducing congestion on the grid, reducing the need for new generation and transmission capacity, and offering ancillary services such as voltage support and emergency demand response. Local aggregations of distributed energy resources (DER) that may include active control of on-site end-use energy devices can be called microgrids. Microgrids require control to ensure safe operation and to make dispatch decisions that achieve system objectives such as cost minimization, reliability, efficiency and emissions requirements, while abiding by system constraints and regulatory rules. This control is performed by an energy manager (EM). Preferably, an EM will achieve operation reasonably close to the attainable optimum, it will do this by means robust to deviations from expected conditions, and it will not itself incur insupportable capital or operation and maintenance costs. Also, microgrids can include supervision over end-uses, such as curtailing or rescheduling certain loads. By viewing a unified microgrid as a system of supply and demand, rather than simply a system of on-site generation devices, the benefits of integrated supply and demand control can be exploited, such as economic savings and improved system energy efficiency.

  13. Quality of HIV laboratory testing in Tanzania: a situation analysis.

    Science.gov (United States)

    Mfinanga, G S; Mutayoba, B; Mbogo, G; Kahwa, A; Kimaro, G; Mhame, P P; Mwangi, C; Malecela, M N; Kitua, A Y

    2007-01-01

    Tanzania is scaling up prevention, treatment, care and support of individuals affected with HIV. There is therefore a need for high quality and reliable HIV infection testing and AIDS staging. The objective of this study was to assess laboratories capacities of services in terms of HIV testing and quality control. A baseline survey was conducted from December 2004 to February 2005 in 12 laboratories which were conveniently selected to represent all the zones of Tanzania. The questionnaires comprised of questions on laboratory particulars, internal and external quality control for HIV testing and quality control of reagents. Source and level of customer satisfaction of HIV test kits supply was established. Of 12 laboratories, nine used rapid tests for screening and two used rapid tests for diagnosis. In the 12 laboratories, four used double ELISA and five used single ELISA and three did not use ELISA. Confirmatory tests observed were Western Blot in three laboratories, DNA PCR in two laboratories, CD4 counting in seven laboratories, and viral load in two laboratories. Although all laboratories conducted quality control (QC) of the HIV kits, only two laboratories had Standard Operating Procedures (SOPs). Internal and external quality control (EQC) was done at varied proportions with the highest frequency of 55.6% (5/9) for internal quality control (IQC) for rapid tests and EQC for ELISA, and the lowest frequency of 14.3% (1/ 7) for IQC for CD4 counting. None of the nine laboratories which conducted QC for reagents used for rapid tests and none of the five which performed IQC and EQC had SOPs. HIV kits were mainly procured by the Medical Store Department and most of laboratories were not satisfied with the delay in procurement procedures. Most of the laboratories used rapid tests only, while some used both rapid tests and ELISA method for HIV testing. In conclusion, the survey revealed inadequacy in Good Laboratory Practice and poor laboratory quality control process

  14. USING LABORATORY TESTS TO PREDICT OXIDATION IN TODAY'S ENGINES

    Institute of Scientific and Technical Information of China (English)

    2004-01-01

    Laboratory bench tests are used to predict lubricant performance in modern engines. The evolution of ASTM (American Society of Testing and Materials) engine Sequence tests and associated laboratory bench tests is reviewed. Several oxidation screening tests are described. Correlation of oxidation screening tests with ASTM Sequence Ⅲ high temperature oxidation engine test is addressed, using both European and ASTM reference oils. Modification of the oxidation screening test methods is attempted in order to improve the correlation as the Sequence Ⅲ test method evolves.

  15. Networked control of microgrid system of systems

    Science.gov (United States)

    Mahmoud, Magdi S.; Rahman, Mohamed Saif Ur; AL-Sunni, Fouad M.

    2016-08-01

    The microgrid has made its mark in distributed generation and has attracted widespread research. However, microgrid is a complex system which needs to be viewed from an intelligent system of systems perspective. In this paper, a network control system of systems is designed for the islanded microgrid system consisting of three distributed generation units as three subsystems supplying a load. The controller stabilises the microgrid system in the presence of communication infractions such as packet dropouts and delays. Simulation results are included to elucidate the effectiveness of the proposed control strategy.

  16. Laboratory tests used in US public health laboratories for sexually transmitted diseases, 2000.

    Science.gov (United States)

    Dicker, Linda Webster; Mosure, Debra J; Steece, Richard; Stone, Katherine M

    2004-05-01

    Public health laboratories are a critical component of sexually transmitted disease (STD) control in the United States. The goal of this study was to describe the types and volume of STD tests performed in U.S. public health laboratories in 2000. A survey was mailed to 123 members of the Association of Public Health Laboratories. Eighty-one percent of 100 laboratories responded. Overall, 3294739 chlamydia tests and 3088142 gonorrhea tests were done; 62.4% of chlamydia tests and 63.6% of gonorrhea tests were DNA probes. Fifty-six percent of laboratories performed rapid plasma reagin (RPR) tests and 55% performed Venereal Disease Research Laboratory (VDRL) tests; the number of RPR tests performed was twice that of VDRL tests. Few laboratories used new technologies for bacterial vaginosis and trichomoniasis. Eighteen percent of laboratories performed herpes simplex virus serology; however, most used inaccurate tests. No laboratories performed human papillomavirus tests. This survey documents for the first time STD tests performed in U.S. public health laboratories.

  17. 16 CFR 305.22 - Required testing by designated laboratory.

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 1 2010-01-01 2010-01-01 false Required testing by designated laboratory...) Additional Requirements § 305.22 Required testing by designated laboratory. Upon notification by the... manufacturer's expense, no more than two of each model of each product to a laboratory, which will...

  18. Microgrid Design Analysis Using Technology Management Optimization and the Performance Reliability Model

    Energy Technology Data Exchange (ETDEWEB)

    Stamp, Jason E. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Eddy, John P. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Jensen, Richard P. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Munoz-Ramos, Karina [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2016-01-01

    Microgrids are a focus of localized energy production that support resiliency, security, local con- trol, and increased access to renewable resources (among other potential benefits). The Smart Power Infrastructure Demonstration for Energy Reliability and Security (SPIDERS) Joint Capa- bility Technology Demonstration (JCTD) program between the Department of Defense (DOD), Department of Energy (DOE), and Department of Homeland Security (DHS) resulted in the pre- liminary design and deployment of three microgrids at military installations. This paper is focused on the analysis process and supporting software used to determine optimal designs for energy surety microgrids (ESMs) in the SPIDERS project. There are two key pieces of software, an ex- isting software application developed by Sandia National Laboratories (SNL) called Technology Management Optimization (TMO) and a new simulation developed for SPIDERS called the per- formance reliability model (PRM). TMO is a decision support tool that performs multi-objective optimization over a mixed discrete/continuous search space for which the performance measures are unrestricted in form. The PRM is able to statistically quantify the performance and reliability of a microgrid operating in islanded mode (disconnected from any utility power source). Together, these two software applications were used as part of the ESM process to generate the preliminary designs presented by SNL-led DOE team to the DOD. Acknowledgements Sandia National Laboratories and the SPIDERS technical team would like to acknowledge the following for help in the project: * Mike Hightower, who has been the key driving force for Energy Surety Microgrids * Juan Torres and Abbas Akhil, who developed the concept of microgrids for military instal- lations * Merrill Smith, U.S. Department of Energy SPIDERS Program Manager * Ross Roley and Rich Trundy from U.S. Pacific Command * Bill Waugaman and Bill Beary from U.S. Northern Command * Tarek Abdallah, Melanie

  19. Comparison of Rapid Malaria Test and Laboratory Microscopy ...

    African Journals Online (AJOL)

    Michael Horsfall

    Comparison of Rapid Malaria Test and Laboratory Microscopy Investigation for ... of the low parasite density cases could escape detection, therefore, it cannot replace laboratory ..... WHO (1990): World Report of the tropical disease,.

  20. Operation Cost Minimization of Droop-Controlled DC Microgrids Based on Real-Time Pricing and Optimal Power Flow

    DEFF Research Database (Denmark)

    Li, Chendan; de Bosio, Federico; Chaudhary, Sanjay Kumar

    2015-01-01

    In this paper, an optimal power flow problem is formulated in order to minimize the total operation cost by considering real-time pricing in DC microgrids. Each generation resource in the system, including the utility grid, is modeled in terms of operation cost, which combines the cost...... problem is solved in a heuristic way by using genetic algorithms. In order to test the proposed algorithm, a six-bus droop-controlled DC microgrid is used as a case-study. The obtained simulation results show that under variable renewable generation, load, and electricity prices, the proposed method can...... successfully dispatch the resources in the microgrid with lower total operation costs....

  1. New technologies to improve laboratory testing

    Science.gov (United States)

    Burtis, C. A.

    Several core technologies that are having, or will have, an impact on the clinical laboratory are discussed. These include instrument-related technologies such as computer technology, chemometrics, robotics, sensors, and biological technologies such as cell fusion and recombinant DNA.

  2. Monitoring and remote control of a hybrid photovoltaic microgrid

    Directory of Open Access Journals (Sweden)

    Henrique Tiggemann

    2016-07-01

    Full Text Available The search of new alternatives for energy supply in island communities has always been a challenge in scientific and social context. In order to attend these communities, in January 2013 a photovoltaic hybrid microgrid project had its beginning at Universidade do Vale do Rio dos Sinos (UNISINOS. This paper presents the characterization and the development of such microgrid, monitored remotely via internet, which allows visualizing the electrical measurements, energy production and performing remote control actions. This work also aims increasing the interaction between students of universities to perform laboratory practices. The system consists of two photovoltaic modules technologies, mono and multicrystalline, totaling 570 Wp, connected to an energy storage bank of 200 Ah in 24 V and a pure sinusoidal inverter of 1 kW to supply AC voltage loads of 220 V. All acquisition components of data, conversion and management system are located in a control cabinet. Currently, the microgrid uses the utility grid as an auxiliary generator, simulating an alternative source of energy, which can be further replaced by fuel cell, biodiesel generator, etc.

  3. Kalaeloa Energy System Redevelopment Options Including Advanced Microgrids.

    Energy Technology Data Exchange (ETDEWEB)

    Hightower, Marion Michael [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Baca, Michael J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); VanderMey, Carissa [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-03-01

    In June 2016, the Department of Energy's (DOE's) Office of Energy Efficiency and Renewable Energy (EERE) in collaboration with the Renewable Energy Branch for the Hawaii State Energy Office (HSEO), the Hawaii Community Development Authority (HCDA), the United States Navy (Navy), and Sandia National Laboratories (Sandia) established a project to 1) assess the current functionality of the energy infrastructure at the Kalaeloa Community Development District, and 2) evaluate options to use both existing and new distributed and renewable energy generation and storage resources within advanced microgrid frameworks to cost-effectively enhance energy security and reliability for critical stakeholder needs during both short-term and extended electric power outages. This report discusses the results of a stakeholder workshop and associated site visits conducted by Sandia in October 2016 to identify major Kalaeloa stakeholder and tenant energy issues, concerns, and priorities. The report also documents information on the performance and cost benefits of a range of possible energy system improvement options including traditional electric grid upgrade approaches, advanced microgrid upgrades, and combined grid/microgrid improvements. The costs and benefits of the different improvement options are presented, comparing options to see how well they address the energy system reliability, sustainability, and resiliency priorities identified by the Kalaeloa stakeholders.

  4. The advanced microgrid. Integration and interoperability

    Energy Technology Data Exchange (ETDEWEB)

    Bower, Ward Isaac [Ward Bower Innovations, LLC, Albuquerque, NM (United Staes); Ton, Dan T. [U.S. Dept. of Energy, Washington, DC (United States); Guttromson, Ross [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Glover, Steven F [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Stamp, Jason Edwin [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Bhatnagar, Dhruv [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Reilly, Jim [Reily Associates, Pittston, PA (United States)

    2014-02-01

    This white paper focuses on "advanced microgrids," but sections do, out of necessity, reference today's commercially available systems and installations in order to clearly distinguish the differences and advances. Advanced microgrids have been identified as being a necessary part of the modern electrical grid through a two DOE microgrid workshops, the National Institute of Standards and Technology, Smart Grid Interoperability Panel and other related sources. With their grid-interconnectivity advantages, advanced microgrids will improve system energy efficiency and reliability and provide enabling technologies for grid-independence to end-user sites. One popular definition that has been evolved and is used in multiple references is that a microgrid is a group of interconnected loads and distributed-energy resources within clearly defined electrical boundaries that acts as a single controllable entity with respect to the grid. A microgrid can connect and disconnect from the grid to enable it to operate in both grid-connected or island-mode. Further, an advanced microgrid can then be loosely defined as a dynamic microgrid.

  5. Model predictive control of smart microgrids

    DEFF Research Database (Denmark)

    Hu, Jiefeng; Zhu, Jianguo; Guerrero, Josep M.

    2014-01-01

    The exploitation of renewable energy and the development of intelligent electricity network have become the main concerns worldwide. This paper aims to integrate renewable energy sources, local loads, and energy storage devices into smart microgrids. It proposes a new microgrid configuration...... and provide high quality electricity for customers....

  6. Modular Power Architectures for Microgrid Clusters

    DEFF Research Database (Denmark)

    Lin, Hengwei; Liu, Leo; Guerrero, Josep M.

    2014-01-01

    . The user-frame concept proposed here when designing microgrids considers that the end-user is the basis for the geographical deployment. Meanwhile, a modular user-oriented approach is adopted in order to enhance reliability and expansibility. Finally, a unified dispatching and hierarchical management...... approach is proposed and evaluated to effectively optimize and manage modular microgrid architectures....

  7. Real-Time Energy Management System for a Hybrid AC/DC Residential Microgrid

    DEFF Research Database (Denmark)

    Diaz, Enrique Rodriguez; Palacios-Garcia, Emilio J.; Anvari-Moghaddam, Amjad

    2017-01-01

    /discharge of the ESS, and the energy injection/consumption from the grid. The EMS estimates the RES generation based on the weather forecasting, together with stochastic consumption modelling of the building. The EMS architecture and the residential microgrid have been implemented and tested in a laboratory scale......) and the building’s common facilities; while the apartments are supplied by an ac distribution system connected to the grid. This architecture avoids any modifications in the electrical installation that supplies energy to the apartments. A pure dc voltage supply is not yet a feasible approach for residential...... buildings. This architecture increases the overall efficiency of the distribution by interconnecting the RES and ESS thorough a dc distribution bus, and therefore avoiding unnecessary dc/ac conversion stages. The real-time EMS performs an 24 hours ahead optimization in order to schedule the charge...

  8. Transportable Emissions Testing Laboratory for Alternative Vehicles Emissions Testing

    Energy Technology Data Exchange (ETDEWEB)

    Clark, Nigel

    2012-01-31

    The overall objective of this project was to perform research to quantify and improve the energy efficiency and the exhaust emissions reduction from advanced technology vehicles using clean, renewable and alternative fuels. Advanced vehicle and alternative fuel fleets were to be identified, and selected vehicles characterized for emissions and efficiency. Target vehicles were to include transit buses, school buses, vocational trucks, delivery trucks, and tractor-trailers. Gaseous species measured were to include carbon monoxide, carbon dioxide, oxides of nitrogen, hydrocarbons, and particulate matter. An objective was to characterize particulate matter more deeply than by mass. Accurate characterization of efficiency and emissions was to be accomplished using a state-of-the-art portable emissions measurement system and an accompanying chassis dynamometer available at West Virginia University. These two units, combined, are termed the Transportable Laboratory. An objective was to load the vehicles in a real-world fashion, using coast down data to establish rolling resistance and wind drag, and to apply the coast down data to the dynamometer control. Test schedules created from actual vehicle operation were to be employed, and a specific objective of the research was to assess the effect of choosing a test schedule which the subject vehicle either cannot follow or can substantially outperform. In addition the vehicle loading objective was to be met better with an improved flywheel system.

  9. 7 CFR 58.523 - Laboratory and quality control tests.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Laboratory and quality control tests. 58.523 Section... Service 1 Operations and Operating Procedures § 58.523 Laboratory and quality control tests. (a) Quality control tests shall be made on samples as often as necessary to determine the shelf-life and stability...

  10. Modeling and Control for Microgrids

    Science.gov (United States)

    Steenis, Joel

    Traditional approaches to modeling microgrids include the behavior of each inverter operating in a particular network configuration and at a particular operating point. Such models quickly become computationally intensive for large systems. Similarly, traditional approaches to control do not use advanced methodologies and suffer from poor performance and limited operating range. In this document a linear model is derived for an inverter connected to the Thevenin equivalent of a microgrid. This model is then compared to a nonlinear simulation model and analyzed using the open and closed loop systems in both the time and frequency domains. The modeling error is quantified with emphasis on its use for controller design purposes. Control design examples are given using a Glover McFarlane controller, gain scheduled Glover McFarlane controller, and bumpless transfer controller which are compared to the standard droop control approach. These examples serve as a guide to illustrate the use of multi-variable modeling techniques in the context of robust controller design and show that gain scheduled MIMO control techniques can extend the operating range of a microgrid. A hardware implementation is used to compare constant gain droop controllers with Glover McFarlane controllers and shows a clear advantage of the Glover McFarlane approach.

  11. Energy Management Strategy Based on Multiple Operating States for a Photovoltaic/Fuel Cell/Energy Storage DC Microgrid

    Directory of Open Access Journals (Sweden)

    Ying Han

    2017-01-01

    Full Text Available It is a great challenge for DC microgrids with stochastic renewable sources and volatility loads to achieve better operation performance. This study proposes an energy management strategy based on multiple operating states for a DC microgrid, which is comprised of a photovoltaic (PV array, a proton exchange membrane fuel cell (PEMFC system, and a battery bank. This proposed strategy can share the power properly and keep the bus voltage steady under different operating states (the state of charge (SOC of the battery bank, loading conditions, and PV array output power. In addition, a microgrids test platform is established. In order to verify the effectiveness of the proposed energy management strategy, the strategy is implemented in a hardware system and experimentally tested under different operating states. The experimental results illustrate the good performance of the proposed control strategy for the DC microgrid under different scenarios of power generation and load demand.

  12. Workgroup for Hydraulic laboratory Testing and Verification of Hydroacoustic Instrumentation

    Science.gov (United States)

    Fulford, Janice M.; Armstrong, Brandy N.; Thibodeaux, Kirk G.

    2015-01-01

    An international workgroup was recently formed for hydraulic laboratory testing and verification of hydroacoustic instrumentation used for water velocity measurements. The activities of the workgroup have included one face to face meeting, conference calls and an inter-laboratory exchange of two acoustic meters among participating laboratories. Good agreement was found among four laboratories at higher tow speeds and poorer agreement at the lowest tow speed.

  13. Laboratory Tests of Small SDHW Systems

    DEFF Research Database (Denmark)

    Furbo, Simon; Shah, Louise Jivan

    1997-01-01

    A test facility for Small SDHW systems was built in 1992. In the test facility up to 10 SDHW systems can be tested side-by-side under the same realistic conditions. Since 1992 16 different systems have been tested in the facility. Both test systems and marketed systems from Danish as well...... as foreign manufacturers have been tested.The thermal performances of the systems have been measured for periods with a duration of about 1 year. In this way direct comparisons of the thermal performances of the different systems are possible.Further, measured and calculated thermal performances for all...... models the yearly thermal performances of the tested systems have been determined with the Danish Test Reference Year as the weather data. Based on calculations with the models improvements of the design of the different systems have been recommended.Experience from the operation of the different systems...

  14. Laboratory Test Requirements for Marine Shock Isolation Seats

    Science.gov (United States)

    2015-05-01

    Program Executive Office Ships, Support Ships, Boats, and Craft Program Office (PMS 325G). ACKNOWLEDGEMENTS The authors would like to thank Mr...laboratory before installation in a high-speed planing craft . It includes testing procedures, instrumentation system guidance, data processing requirements...or techniques are developed. . 15. SUBJECT TERMS Shock isolation seat laboratory test high-speed craft 16. SECURITY

  15. 7 CFR 58.442 - Laboratory and quality control tests.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Laboratory and quality control tests. 58.442 Section... Service 1 Operations and Operating Procedures § 58.442 Laboratory and quality control tests. (a) Chemical... Methods or by other methods giving equivalent results. (b) Weight or volume control....

  16. [Basic standards for Colombian paternity testing laboratories, 2005].

    Science.gov (United States)

    Giraldo, Alejandro; Bermúdez, Antonio; Jiménez, Magda; Lizarazo, Rocio

    2006-01-01

    The Commission for Accreditation and Surveillance of Laboratories Practicing DNA Paternity Tests (created by the Colombian Law 721/2001) set up sub-commission to review the current basic Colombian standards required for paternity testing laboratories and make specific recommendations re the pertinent technical aspects in Colombia, taking ISO 17025 as current reference. This document contains such recommendations for Colombia.

  17. 19 CFR 151.54 - Testing by Customs laboratory.

    Science.gov (United States)

    2010-04-01

    ... 19 Customs Duties 2 2010-04-01 2010-04-01 false Testing by Customs laboratory. 151.54 Section 151.54 Customs Duties U.S. CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT OF... Other Metal-Bearing Materials § 151.54 Testing by Customs laboratory. Samples taken in accordance...

  18. Human Papillomavirus Laboratory Testing: the Changing Paradigm

    Science.gov (United States)

    2016-01-01

    SUMMARY High-risk human papillomaviruses (HPVs) cause essentially all cervical cancers, most anal and oropharyngeal cancers, and some vaginal, vulvar, and penile cancers. Improved understanding of the pathogenesis of infection and the availability of newer tests are changing the approach to screening and diagnosis. Molecular tests to detect DNA from the most common high-risk HPVs are FDA approved for use in conjunction with cytology in cervical cancer screening programs. More-specific tests that detect RNA from high-risk HPV types are now also available. The use of molecular tests as the primary screening tests is being adopted in some areas. Genotyping to identify HPV16 and -18 has a recommended role in triaging patients for colposcopy who are high-risk HPV positive but have normal cytology. There are currently no recommended screening methods for anal, vulvar, vaginal, penile, or oropharyngeal HPV infections. HPV testing has limited utility in patients at high risk for anal cancer, but p16 immunohistochemistry is recommended to clarify lesions in tissue biopsy specimens that show moderate dysplasia or precancer mimics. HPV testing is recommended for oropharyngeal squamous cell tumors as a prognostic indicator. Ongoing research will help to improve the content of future guidelines for screening and diagnostic testing. PMID:26912568

  19. Recent laboratory tests with elastomeric revetments

    NARCIS (Netherlands)

    Verhagen, H.J.

    2009-01-01

    A new construction method of Polyurethane (PUR)-bonded revetments has been tested successfully on various locations in Germany, in the Netherlands, in France, and in the UK. See also the presentation of Bijlsma on this ICE breakwater conference. This year a series of large scale test in the GWK-faci

  20. Advanced Laboratory Setup for Testing Offshore Foundations

    DEFF Research Database (Denmark)

    Nielsen, Søren Dam; Ibsen, Lars Bo; Nielsen, Benjaminn Nordahl

    2016-01-01

    This paper describes a test setup for testing small-scale offshore foundations under realistic conditions of high pore-water pressure and high impact loads. The actuator, used for loading has enough capacity to apply sufficient force and displacement to achieve both drained and undrained failure ...

  1. Design, Operation, and Controlled-Island Operation of the U.S. Department of Energy Solar Decathlon 2013 Microgrid

    Energy Technology Data Exchange (ETDEWEB)

    Kurnik, C. [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Butt, R. S. [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Metzger, I. [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Lavrova, O. [Univ. of New Mexico, Albuquerque, NM (United States); Patibandla, S. [Univ. of New Mexico, Albuquerque, NM (United States); Wagner, V. [Schneider Electric, Knoxville, TN (United States); Frankosky, M. [Schneider Electric, Knoxville, TN (United States); Wiegand, G. [MicroPlanet, Inc., Woodinville, WA (United States)

    2015-04-22

    This document reports on the design and operation of a high-capacity and high-penetration-ratio microgrid, which consists of 19 photovoltaic-powered residential houses designed by collegiate teams as part of their participation in the U.S. Department of Energy Solar Decathlon 2013. The microgrid was interconnected with the local utility, and resulting net-power and power-quality events were recorded in high detail (1-minute data sampling or better). Also, a controlled-island operation test was conducted to evaluate the microgrid response to additional events such as increased loads (e.g., from electric vehicles) and bypassing of voltage regulators. This temporary ground-laid microgrid was stable under nominal and island-operation conditions; adverse weather and loads did not lead to power-quality degradation.

  2. Inter-laboratory proficiency tests to detect viral fish diseases

    DEFF Research Database (Denmark)

    Kahns, Søren; Nicolajsen, Nicole; Skall, Helle Frank

    of the rhabdoviruses identified in order to analyse the inter-laboratory quality of sequencing results. Such results are very important for assessing how sequence data can be used in e.g. molecular tracing. Here we present results and experiences obtained from these additional studies.......An inter-laboratory proficiency test has ben provided by the European Community Laboratory (CRL) for Fish Diseases every year since 1996. The test is provided to all European National Reference Laboratories (NRLs) that are obliged to participate and to a limited number of non-European NRLs, making...... the total number of participating laboratories 35. The test is primarily designed to assess the ability of participating laboratories to identify and quantify the notifiable non-exotic fish pathogenic viruses: Viral haemorrhagic septicaemia virus (VHSV) and infectious haematopietic necrosis virus (IHNV...

  3. Experimental framework for laboratory scale microgrids

    Directory of Open Access Journals (Sweden)

    José Alex Restrepo-Zambrano

    2016-01-01

    Full Text Available Este artículo presenta una propuesta de un banco de pruebas de microrredes para uso en laboratorio. El objetivo es proporcionar alta flexibilidad utilizando un enfoque modular con un hardware común para la mayoría de las tareas. El marco experimental propuesto para microrredes a escala de laboratorio proporciona los requisitos para enseñanza e investigación. Esto se logra con una etapa de electrónica de potencia reconfigurable, para pruebas y diseños de nuevas topologías. Permite probar algoritmos en los distintos niveles de la estructura jerárquica de la microrred. Da acceso a la emulación y simulación de elementos encontrados comúnmente en una microrred y a la programación de bajo nivel de los protocolos de comunicación para estudiar el canal de comunicación. La unidad de procesamiento en cada módulo, llamado controlador local, utiliza un procesador digital de señales de alto rendimiento (DSP. Esta unidad de procesamiento permite la reconfiguración de cada módulo para asumir cualquier tarea en la microrred; es decir, como cargas controlables, almacenamiento de energía, generación eólica, generación fotovoltaica, etc. El hardware propuesto se probó operando como emulador de los diferentes subsistemas. Las comunicaciones con un controlador central microrred (MCC se realizan mediante procesadores integrados estándar, capaces de implementar los protocolos de comunicación adecuados para ambientes de microrred.

  4. Optimal Protection Coordination for Microgrid under Different Operating Modes

    Directory of Open Access Journals (Sweden)

    Ming-Ta Yang

    2013-01-01

    Full Text Available Significant consequences result when a microgrid is connected to a distribution system. This study discusses the impacts of bolted three-phase faults and bolted single line-to-ground faults on the protection coordination of a distribution system connected by a microgrid which operates in utility-only mode or in grid-connected mode. The power system simulation software is used to build the test system. The linear programming method is applied to optimize the coordination of relays, and the relays coordination simulation software is used to verify if the coordination time intervals (CTIs of the primary/backup relay pairs are adequate. In addition, this study also proposes a relays protection coordination strategy when the microgrid operates in islanding mode during a utility power outage. Because conventional CO/LCO relays are not capable of detecting high impedance fault, intelligent electrical device (IED combined with wavelet transformer and neural network is proposed to accurately detect high impedance fault and identify the fault phase.

  5. Laboratory effectiveness testing of oil spill dispersants

    Energy Technology Data Exchange (ETDEWEB)

    Fingas, M.F.; Kyle, D.A.; Wang, Z.; Handfield, D.; Ianuzzi, D.; Ackerman, F. [Environment Canada, Ottawa, Ontario (Canada)

    1995-06-01

    Dispersant effectiveness tests are reviewed. Studies have been conducted of the variances among several standard regulatory tests. Three main causes of differences have been identified, oil-to-water ratio, settling time and energy. Energy can be partially compensated for in high energy tests by correcting for natural dispersion. With this correction and with high oil-to-water ratios and a settling time of at least 10 minutes, five apparatuses yield very similar results for a variety of oils and dispersants. Recent studies into the energy variation of dispersant tests show that the energy level varies in many apparatuses. The repeatability of energy levels in apparatus is largely responsible for the variation in dispersant effectiveness values in certain apparatus. Studies of analytical procedures show that traditional extraction and analysis methods cause a bias to results. Methods to overcome these difficulties are presented.

  6. Energy management and cooperation in microgrids

    Science.gov (United States)

    Rahbar, Katayoun

    Microgrids are key components of future smart power grids, which integrate distributed renewable energy generators to efficiently serve the load demand locally. However, random and intermittent characteristics of renewable energy generations may hinder the reliable operation of microgrids. This thesis is thus devoted to investigating new strategies for microgrids to optimally manage their energy consumption, energy storage system (ESS) and cooperation in real time to achieve the reliable and cost-effective operation. This thesis starts with a single microgrid system. The optimal energy scheduling and ESS management policy is derived to minimize the energy cost of the microgrid resulting from drawing conventional energy from the main grid under both the off-line and online setups, where the renewable energy generation/load demand are assumed to be non-causally known and causally known at the microgrid, respectively. The proposed online algorithm is designed based on the optimal off-line solution and works under arbitrary (even unknown) realizations of future renewable energy generation/load demand. Therefore, it is more practically applicable as compared to solutions based on conventional techniques such as dynamic programming and stochastic programming that require the prior knowledge of renewable energy generation and load demand realizations/distributions. Next, for a group of microgrids that cooperate in energy management, we study efficient methods for sharing energy among them for both fully and partially cooperative scenarios, where microgrids are of common interests and self-interested, respectively. For the fully cooperative energy management, the off-line optimization problem is first formulated and optimally solved, where a distributed algorithm is proposed to minimize the total (sum) energy cost of microgrids. Inspired by the results obtained from the off-line optimization, efficient online algorithms are proposed for the real-time energy management

  7. Laboratory results of the AOF system testing

    Science.gov (United States)

    Kolb, Johann; Madec, Pierre-Yves; Arsenault, Robin; Oberti, Sylvain; Paufique, Jérôme; La Penna, Paolo; Ströbele, Stefan; Donaldson, Robert; Soenke, Christian; Suárez Valles, Marcos; Kiekebusch, Mario; Argomedo, Javier; Le Louarn, Miska; Vernet, Elise; Haguenauer, Pierre; Duhoux, Philippe; Aller-Carpentier, Emmanuel; Valenzuela, Jose Javier; Guerra, Juan Carlos

    2016-07-01

    For two years starting in February 2014, the AO modules GRAAL for HAWK-I and GALACSI for MUSE of the Adaptive Optics Facility project have undergone System Testing at ESO's Headquarters. They offer four different modes: NGS SCAO, LGS GLAO in the IR, LGS GLAO and LTAO in the visible. A detailed characterization of those modes was made possible by the existence of ASSIST, a test bench emulating an adaptive VLT including the Deformable Secondary Mirror, a star simulator and turbulence generator and a VLT focal plane re-imager. This phase aimed at validating all the possible components and loops of the AO modules before installation at the actual VLT that comprises the added complexity of real LGSs, a harsher non-reproducible environment and the adaptive telescope control. In this paper we present some of the major results obtained and challenges encountered during the phase of System Tests, like the preparation of the Acquisition sequence, the testing of the Jitter loop, the performance optimization in GLAO and the offload of low-order modes from the DSM to the telescope (restricted to the M2 hexapod). The System Tests concluded with the successful acceptance, shipping, installation and first commissioning of GRAAL in 2015 as well as the acceptance and shipping of GALACSI, ready for installation and commissioning early 2017.

  8. Coordination Control Strategy for AC/DC Hybrid Microgrids in Stand-Alone Mode

    Directory of Open Access Journals (Sweden)

    Dwi Riana Aryani

    2016-06-01

    Full Text Available Interest in DC microgrids is rapidly increasing along with the improvement of DC power technology because of its advantages. To support the integration process of DC microgrids with the existing AC utility grids, the form of hybrid AC/DC microgrids is considered for higher power conversion efficiency, lower component cost and better power quality. In the system, AC and DC portions are connected through interlink bidirectional AC/DC converters (IC with a proper control system and power management. In the stand-alone operation mode of AC/DC hybrid microgrids, the control of power injection through the IC is crucial in order to maintain the system security. This paper mainly deals with a coordination control strategy of IC and a battery energy storage system (BESS converter under stand-alone operation. A coordinated control strategy for the IC, which considers the state of charge (SOC level of BESS and the load shedding scheme as the last resort, is proposed to obtain better power sharing between AC and DC subgrids. The scheme will be tested with a hybrid AC/DC microgrid, using the tool of the PSCAD/EMTDC software.

  9. Influence of diet on the results of laboratory tests

    Directory of Open Access Journals (Sweden)

    Kinga Lis

    2013-12-01

    Full Text Available Blood and urine laboratory tests are necessary to diagnose the state of the patient. These tests are also helpful in the assessment of diet and nutritional status of the organism. It is recommended that both blood and urine for laboratory tests be collected in the morning, from fasting patients after an overnight rest. These conditions are defined as the standard conditions for collection of material for laboratory testing. Before testing, patients should follow their natural diet and avoid physical exertion, night work, long-distance travel, as well as consumption of alcohol and drugs. They should also reduce the consumption of synthetic vitamins and herbal remedies and other dietary supplements. Medications should be limited to those that are absolutely necessary. All of these factors can affect the results of laboratory tests.

  10. Laboratory tests of hydraulic fracturing and swell healing

    DEFF Research Database (Denmark)

    Thunbo, Christensen Claes; Foged, Christensen Helle; Foged, Niels

    1998-01-01

    New laboratory test set-ups and test procedures are described - for testing the formation of hydraulically induced fractures as well as the potential for subsequent fracture closurefrom the relase of a swelling potential. The main purpose with the tests is to provide information on fracturing...

  11. Laboratory-scale integrated ARP filter test

    Energy Technology Data Exchange (ETDEWEB)

    Poirier, M. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Burket, P. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2016-03-01

    The Savannah River Site (SRS) is currently treating radioactive liquid waste with the Actinide Removal Process (ARP) and the Modular Caustic Side Solvent Extraction Unit (MCU). Recently, the low filter flux through the ARP of approximately 5 gallons per minute has limited the rate at which radioactive liquid waste can be treated. Salt Batch 6 had a lower processing rate and required frequent filter cleaning. There is a desire to understand the causes of the low filter flux and to increase ARP/MCU throughput. This task attempted to simulate the entire ARP process, including multiple batches (5), washing, chemical cleaning, and blending the feed with heels and recycle streams. The objective of the tests was to determine whether one of these processes is causing excessive fouling of the crossflow or secondary filter. The authors conducted the tests with feed solutions containing 6.6 M sodium Salt Batch 6 simulant supernate with no MST.

  12. The Farley Instability: A Laboratory Test

    DEFF Research Database (Denmark)

    D'Angelo, N.; Pécseli, Hans; Petersen, P. I.

    1974-01-01

    An experiment is described that was performed in an alkali plasma (Cs) device in order to test the theory of the Farley instability. With υ E×B > Cs (the speed of sound) and νι ≳ ω cι (ν e ≪ ω ce ) wave excitation occurs, the waves traveling normal to the magnetic field B at the υ E×B speed....... The perturbations are strongly elongated along the B field lines, with λ∥ ≫ λ⊥. A comparison with theoretical predictions is given for the observed excitation conditions of the instability....

  13. Laboratory Facilities for Testing Thermal Engines

    Directory of Open Access Journals (Sweden)

    Ioan Ruja

    2010-10-01

    Full Text Available This work presents an electromechanical plant through with which is realised couples different resistant, MR (0 ÷ MRN, on the gearbox shaft of internal combustion engine. The purpose is to study the plant in phase and stationary behaviour of the main technical parameters that define the engine operation such as: torque, speed, temperature, pressure, vibration, burnt gas, noise, forces. You can take measurements to determine engine performance testing and research on improving engine thermal efficiency. With the proposed plant is built by measuring the characteristic internal combustion engines (tuning characteristic and functional characteristic and determine the technical performance of interest, optimal.

  14. Computational optimization techniques applied to microgrids planning

    DEFF Research Database (Denmark)

    Gamarra, Carlos; Guerrero, Josep M.

    2015-01-01

    appear along the planning process. In this context, technical literature about optimization techniques applied to microgrid planning have been reviewed and the guidelines for innovative planning methodologies focused on economic feasibility can be defined. Finally, some trending techniques and new...

  15. 42 CFR 493.1441 - Condition: Laboratories performing high complexity testing; laboratory director.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Condition: Laboratories performing high complexity testing; laboratory director. 493.1441 Section 493.1441 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) STANDARDS AND CERTIFICATION...

  16. Draft Test Guideline: Generic Freshwater Microcosm Test, Laboratory

    Science.gov (United States)

    The following draft test guideline is part of a series of test guidelines that have been developed by EPA for use in the testing of pesticides and toxic substances, and the development of test data for submission to the Agency for review.

  17. Smallpox Vaccination of Laboratory Workers at US Variola Testing Sites.

    Science.gov (United States)

    Medcalf, Sharon; Bilek, Laura; Hartman, Teresa; Iwen, Peter C; Leuschen, Patricia; Miller, Hannah; O'Keefe, Anne; Sayles, Harlan; Smith, Philip W

    2015-08-01

    To evaluate the need to revaccinate laboratory workers against smallpox, we assessed regular revaccination at the US Laboratory Response Network's variola testing sites by examining barriers to revaccination and the potential for persistence of immunity. Our data do not provide evidence to suggest prolonging the recommended interval for revaccination.

  18. Inadequate Information in Laboratory Test Requisition in a Tertiary ...

    African Journals Online (AJOL)

    Inadequate Information in Laboratory Test Requisition in a Tertiary Hospital in Benin City, ... Abstract. Aim: Laboratory investigations are important aspect of patient ... A total of 1786 (48.1%) of the request form had one or more incomplete or ...

  19. Analysis of critical operating conditions for LV distribution networks with microgrids

    Science.gov (United States)

    Zehir, M. A.; Batman, A.; Sonmez, M. A.; Font, A.; Tsiamitros, D.; Stimoniaris, D.; Kollatou, T.; Bagriyanik, M.; Ozdemir, A.; Dialynas, E.

    2016-11-01

    Increase in the penetration of Distributed Generation (DG) in distribution networks, raises the risk of voltage limit violations while contributing to line losses. Especially in low voltage (LV) distribution networks (secondary distribution networks), impacts of active power flows on the bus voltages and on the network losses are more dominant. As network operators must meet regulatory limitations, they have to take into account the most critical operating conditions in their systems. In this study, it is aimed to present the impact of the worst operation cases of LV distribution networks comprising microgrids. Simulation studies are performed on a field data-based virtual test-bed. The simulations are repeated for several cases consisting different microgrid points of connection with different network loading and microgrid supply/demand conditions.

  20. A Novel Secondary Control for Microgrid Based on Synergetic Control of Multi-Agent System

    Directory of Open Access Journals (Sweden)

    Zhiwen Yu

    2016-03-01

    Full Text Available In power systems, the secondary control is a very useful way to restore the system frequency and voltage to the rated value. This paper tries to propose a secondary frequency and voltage control of islanded microgrids based on the distributed synergetic control of multi-agent systems. In the proposed control, since each distributed generation only requires its own information and that of the neighbors, the secondary control is fully distributed. The system is more reliable because the central controller and complex communication network are reduced in the distributed structure. Based on multi-agent systems, the dynamic model is established, and distributed synergetic control algorithms are given to design the secondary control of the islanded microgrid. Meanwhile, the system has globally asymptotic stability under the proposed control, which is proved by the direct Lyapunov method. Simulation results about a test microgrid are given to verify the effectiveness of the proposed control.

  1. [The postcoital test: clinico-laboratory observations].

    Science.gov (United States)

    Stanislavov, R; Nalbanski, B; Pŭnevska, M

    1999-01-01

    The choice of optimal time, the technique and limitations of the post-coital test (PCT) have been described. They are of important significance for getting reliable information both concerning the cervical mucus, quality and migration of spermatozoa in female genital tract. It has been stressed that a negative PCT does not necessary exclude pregnancy. There are shown data for prognostic value of the PCT. The observation of more than 20 motility spermatozoa per HPF and higher frequency of pregnancy is common finding in comparison to low motility and number of spermatozoa in cervical mucus. The data support the hypothesis of "filtering" mechanism, excluding entrance of abnormal spermatozoa. Observing "shaking" phenomenon directs to searching immunological factor (local or systemic) against male gametes.

  2. Cooperative Frequency Control for Autonomous AC Microgrids

    DEFF Research Database (Denmark)

    Shafiee, Qobad; Quintero, Juan Carlos Vasquez; Guerrero, Josep M.

    2015-01-01

    Distributed secondary control strategies have been recently studied for frequency regulation in droop-based AC Microgrids. Unlike centralized secondary control, the distributed one might fail to provide frequency synchronization and proportional active power sharing simultaneously, due to having...... not require measuring the system frequency as compared to the other presented methods. An ac Microgrid with four sources is used to verify the performance of the proposed control methodology....

  3. Providing clinicians with information on laboratory test costs leads to ...

    African Journals Online (AJOL)

    Providing clinicians with information on laboratory test costs leads to ... Log in or Register to get access to full text downloads. ... For the intervention and control groups, pre- and postintervention cost and days in hospital were estimated.

  4. Control System for a Diesel Generator and UPS Based Microgrid

    Science.gov (United States)

    Palamar, Andriy; Pettai, Elmo; Beldjajev, Viktor

    2010-01-01

    In this paper a microgrid composed of a diesel generator and two uninterruptible power supply systems with separate battery banks is introduced. The microgrid located in three academic buildings of Tallinn University of Technology. A three-level control and monitoring system for the microgrid based on the EtherNet/IP communication network is developed. In addition, a control strategy of the microgrid in the grid-connected and stand-alone mode of operation is proposed.

  5. Control System for a Diesel Generator and UPS Based Microgrid

    OpenAIRE

    Palamar, A; Pettai, E; Beldjajev, v

    2010-01-01

    In this paper a microgrid composed of a diesel generator and two uninterruptible power supply systems with separate battery banks is introduced. The microgrid located in three academic buildings of Tallinn University of Technology. A three-level control and monitoring system for the microgrid based on the EtherNet/IP communication network is developed. In addition, a control strategy of the microgrid in the grid-connected and stand-alone mode of operation is proposed

  6. Current control loop design and analysis based on resonant regulators for microgrid applications

    DEFF Research Database (Denmark)

    Federico, de Bosio; Pastorelli, Michelle; de Sousa Ribeiro, Luiz Antonio

    2015-01-01

    Voltage and current control loops play an important role in the performance of microgrids employing power electronics voltage source inverters. Correct design of feedback loops is essential for the proper operation of these systems. This paper analyzes the influence of state feedback cross......-coupling in the design of resonant regulators for inner current loops in power converters operating in standalone microgrids. It is also demonstrated that the effect of state feedback cross-coupling degrades the performance of the control loops by increasing the steady-state error. Different resonant regulators...... structures are analyzed and compared, performing experimental tests to validate the results of the theoretical analysis....

  7. Equalization Algorithm for Distributed Energy Storage Systems in Islanded AC Microgrids

    DEFF Research Database (Denmark)

    Aldana, Nelson Leonardo Diaz; Hernández, Adriana Carolina Luna; Quintero, Juan Carlos Vasquez

    2015-01-01

    This paper presents a centralized strategy for equalizing the state of charge of distributed energy storage systems in an islanded ac microgrid. The strategy is based on a simple algorithm denoted as equalization algorithm, which modifies the charge or discharge ratio on the time, for distributed...... energy storage systems, within a determined period of time in order to equalize the state of charge. The proposed approach has been tested in a MATLAB/Simulink model of the microgrid where the performance of the proposed strategy was verified....

  8. Immediate needs for MQA testing at state secondary calibration laboratories

    Energy Technology Data Exchange (ETDEWEB)

    Cline, R. [Radiation Instrument Calibration Laboratory, Springfield, IL (United States)

    1993-12-31

    The Calibration Laboratory attempts to provide services that satisfy the needs and requests for a variety of customers. New needs and requests have resulted in calibration of instrumentation outside the original laboratory designs. These tasks require several changes at the laboratory and a need for new support services, especially measurement quality assurance (MQA). The MQA tests are gamma (Cs-137) below 0.5 mrem (5{mu}Sv) per hour and x-ray kVp. Modification to the current gamma (Cs-137) MQA test is recommended because lower intensity fields are commonly measured.

  9. Imaging and laboratory testing in acute abdominal pain.

    Science.gov (United States)

    Panebianco, Nova L; Jahnes, Katherine; Mills, Angela M

    2011-05-01

    When discussing which laboratory tests or imaging to order in the setting of acute abdominal pain, it is practical to organize information by disease process (eg, acute appendicitis, cholecystitis). Because studies on the accuracy of diagnostic tests are of necessity related to the presence or absence of specific diagnoses, and because clinicians frequently look to tests to help them rule in or rule out specific conditions, this article is organized by region of pain and common abdominal diagnoses. It focuses on the contributions that laboratory testing and imaging make in the emergency management of abdominal complaints. Copyright © 2011 Elsevier Inc. All rights reserved.

  10. Towards a rational antimicrobial testing policy in the laboratory

    Directory of Open Access Journals (Sweden)

    N Banaji

    2011-01-01

    Full Text Available Antimicrobial policy for prophylactic and therapeutic use of antimicrobials in a tertiary care setting has gained importance. A hospital′s antimicrobial policy as laid down by its hospital infection control team needs to include inputs from the microbiology laboratory, besides the pharmacy and therapeutic committee. Therefore, it is of utmost importance that clinical microbiologists across India follow international guidelines and also take into account local settings, especially detection and presence of resistance enzymes. This article draws a framework for rational antimicrobial testing in our laboratories in tertiary care centers, from the Clinical and Laboratory Standards Institute guidelines. It does not address testing methodologies but suggests ways and means by which antimicrobial susceptibility reporting can be rendered meaningful not only to the treating physician but also to the resistance monitoring epidemiologist. It hopes to initiate some standardization in rational choice of antimicrobial testing in laboratories in the country pertaining to nonfastidious bacteria.

  11. Towards a rational antimicrobial testing policy in the laboratory.

    Science.gov (United States)

    Banaji, N; Oommen, S

    2011-01-01

    Antimicrobial policy for prophylactic and therapeutic use of antimicrobials in a tertiary care setting has gained importance. A hospital's antimicrobial policy as laid down by its hospital infection control team needs to include inputs from the microbiology laboratory, besides the pharmacy and therapeutic committee. Therefore, it is of utmost importance that clinical microbiologists across India follow international guidelines and also take into account local settings, especially detection and presence of resistance enzymes. This article draws a framework for rational antimicrobial testing in our laboratories in tertiary care centers, from the Clinical and Laboratory Standards Institute guidelines. It does not address testing methodologies but suggests ways and means by which antimicrobial susceptibility reporting can be rendered meaningful not only to the treating physician but also to the resistance monitoring epidemiologist. It hopes to initiate some standardization in rational choice of antimicrobial testing in laboratories in the country pertaining to nonfastidious bacteria.

  12. Problems and solutions in laboratory testing for hemophilia.

    Science.gov (United States)

    Favaloro, Emmanuel J; Meijer, Piet; Jennings, Ian; Sioufi, John; Bonar, Roslyn A; Kitchen, Dianne P; Kershaw, Geoffrey; Lippi, Giuseppe

    2013-10-01

    A diagnosis of hemophilia A or hemophilia B begins with clinical assessment of the patient and is facilitated by laboratory testing. The influence of the latter on a diagnosis of hemophilia A or hemophilia B is clear-a diagnosis cannot be made without laboratory confirmation of a deficiency of factor FVIII (FVIII) or factor IX (FIX), respectively. Moreover, the degree of hemophilia severity is specifically characterized by laboratory test results. In turn, patient management, including choice and application of therapies, is influenced by the diagnosis, as well as by identification of respective disease severity. An incorrect diagnosis may lead to inappropriate management and unnecessary therapy, and thus to adverse outcomes. Moreover, identification of factor inhibitors in hemophilia will lead to additional and differential treatments, and incorrect identification of inhibitors or inhibitor levels may also lead to inappropriate management. Problems in hemophilia diagnosis or inhibitor detection can occur at any stage in the clinical diagnosis/laboratory interface, from the "pre-preanalytical" to "preanalytical" to "analytical" to "postanalytical" to "post-postanalytical." This report outlines the various problems in laboratory testing for hemophilia and provides various strategies or solutions to overcome these challenges. Although some outlined solutions are specific to the potential errors related to hemophilia, others are general in nature and can be applied to other areas of laboratory hemostasis. Key to improvement in this area is adoption of best practice by all involved, including clinicians, phlebotomists, and laboratories. Also key is the recognition that such errors may occur, and thus that clinicians should assess laboratory test results in the context of their patient's clinical history and follow-up any potential errors, thus avoid misdiagnoses, by requesting repeat testing on a fresh sample.

  13. System Quality Management in Software Testing Laboratory that Chooses Accreditation

    Directory of Open Access Journals (Sweden)

    Yanet Brito R.

    2013-12-01

    Full Text Available The evaluation of software products will reach full maturity when executed by the scheme and provides third party certification. For the validity of the certification, the independent laboratory must be accredited for that function, using internationally recognized standards. This brings with it a challenge for the Industrial Laboratory Testing Software (LIPS, responsible for testing the products developed in Cuban Software Industry, define strategies that will permit it to offer services with a high level of quality. Therefore it is necessary to establish a system of quality management according to NC-ISO/IEC 17025: 2006 to continuously improve the operational capacity and technical competence of the laboratory, with a view to future accreditation of tests performed. This article discusses the process defined in the LIPS for the implementation of a Management System of Quality, from the current standards and trends, as a necessary step to opt for the accreditation of the tests performed.

  14. Energy management of an experimental microgrid coupled to a V2G system

    Science.gov (United States)

    Mendes, Paulo R. C.; Isorna, Luis Valverde; Bordons, Carlos; Normey-Rico, Julio E.

    2016-09-01

    This paper presents an algorithm for economic optimization of a laboratory microgrid. The microgrid incorporates a hybrid storage system composed of a battery bank and a hydrogen storage and it has a connection with the external electrical network and a charging station for electric vehicles. To study the impact of use of renewable energy power systems, the microgrid has a programmable power supply that can emulate the dynamic behavior of a wind turbine and/or a photovoltaic field. The system modeling was carried out using the Energy Hubs methodology. A hierarchical control structure is proposed based on Model Predictive Control and acting in different time scales, where the first level is responsible for maintaining the microgrid stability and the second level has the task of performing the management of electricity purchase and sale to the power grid, maximize the use of renewable energy sources, manage the use of energy storages and perform the charge of the parked vehicles. Practical experiments were performed with different weather conditions of solar irradiation and wind. The results show a reliable operation of the proposed control system.

  15. Economic Power Dispatch of Distributed Generators in a Grid-Connected Microgrid

    DEFF Research Database (Denmark)

    Hernández, Adriana Carolina Luna; Aldana, Nelson Leonardo Diaz; Andrade, Fabio

    2015-01-01

    in the storage system for the next day. Linear models are proposed for the scheduling which are implemented in GAMS. The microgrid model is obtained deploying MATLAB/Simulink toolbox and then downloaded into dSPACE 1006 platform based on real-time simulation to test the economic dispatch. A compromise between...

  16. Village microgrids: The Chile project

    Energy Technology Data Exchange (ETDEWEB)

    Baring-Gould, E.I.

    1997-12-01

    This paper describes a village application in Chile. The objective was to demonstrate the technical, economic and institutional viability of renewable energy for rural electrification, as well as to allow local partners to gain experience with hybrid/renewable technology, resource assessment, system siting and operation. A micro-grid system is viewed as a small village system, up to 1200 kWh/day load with a 50 kW peak load. It can consist of components of wind, photovoltaic, batteries, and conventional generators. It is usually associated with a single generator source, and uses batteries to cover light day time loads. This paper looks at the experiences learned from this project with regard to all of the facets of planning and installing this project.

  17. Deep Borehole Field Test Laboratory and Borehole Testing Strategy

    Energy Technology Data Exchange (ETDEWEB)

    Kuhlman, Kristopher L. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Brady, Patrick V. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); MacKinnon, Robert J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Heath, Jason E. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Herrick, Courtney G. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Jensen, Richard P. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Gardner, W. Payton [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Sevougian, S. David [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Bryan, Charles R. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Jang, Je-Hun [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Stein, Emily R. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Bauer, Stephen J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Daley, Tom [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Freifeld, Barry M. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Birkholzer, Jens [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Spane, Frank A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-09-19

    Deep Borehole Disposal (DBD) of high-level radioactive wastes has been considered an option for geological isolation for many years (Hess et al. 1957). Recent advances in drilling technology have decreased costs and increased reliability for large-diameter (i.e., ≥50 cm [19.7”]) boreholes to depths of several kilometers (Beswick 2008; Beswick et al. 2014). These advances have therefore also increased the feasibility of the DBD concept (Brady et al. 2009; Cornwall 2015), and the current field test design will demonstrate the DBD concept and these advances. The US Department of Energy (DOE) Strategy for the Management and Disposal of Used Nuclear Fuel and High-Level Radioactive Waste (DOE 2013) specifically recommended developing a research and development plan for DBD. DOE sought input or expression of interest from States, local communities, individuals, private groups, academia, or any other stakeholders willing to host a Deep Borehole Field Test (DBFT). The DBFT includes drilling two boreholes nominally 200m [656’] apart to approximately 5 km [16,400’] total depth, in a region where crystalline basement is expected to begin at less than 2 km depth [6,560’]. The characterization borehole (CB) is the smaller-diameter borehole (i.e., 21.6 cm [8.5”] diameter at total depth), and will be drilled first. The geologic, hydrogeologic, geochemical, geomechanical and thermal testing will take place in the CB. The field test borehole (FTB) is the larger-diameter borehole (i.e., 43.2 cm [17”] diameter at total depth). Surface handling and borehole emplacement of test package will be demonstrated using the FTB to evaluate engineering feasibility and safety of disposal operations (SNL 2016).

  18. Laboratory Diagnostics Market in East Africa: A Survey of Test Types, Test Availability, and Test Prices in Kampala, Uganda.

    Directory of Open Access Journals (Sweden)

    Lee F Schroeder

    Full Text Available Diagnostic laboratory tests are routinely defined in terms of their sensitivity, specificity, and ease of use. But the actual clinical impact of a diagnostic test also depends on its availability and price. This is especially true in resource-limited settings such as sub-Saharan Africa. We present a first-of-its-kind report of diagnostic test types, availability, and prices in Kampala, Uganda.Test types (identity and availability were based on menus and volumes obtained from clinical laboratories in late 2011 in Kampala using a standard questionnaire. As a measure of test availability, we used the Availability Index (AI. AI is the combined daily testing volumes of laboratories offering a given test, divided by the combined daily testing volumes of all laboratories in Kampala. Test prices were based on a sampling of prices collected in person and via telephone surveys in 2015.Test volumes and menus were obtained for 95% (907/954 of laboratories in Kampala city. These 907 laboratories offered 100 different test types. The ten most commonly offered tests in decreasing order were Malaria, HCG, HIV serology, Syphilis, Typhoid, Urinalysis, Brucellosis, Stool Analysis, Glucose, and ABO/Rh. In terms of AI, the 100 tests clustered into three groups: high (12 tests, moderate (33 tests, and minimal (55 tests availability. 50% and 36% of overall availability was provided through private and public laboratories, respectively. Point-of-care laboratories contributed 35% to the AI of high availability tests, but only 6% to the AI of the other tests. The mean price of the most commonly offered test types was $2.62 (range $1.83-$3.46.One hundred different laboratory test types were in use in Kampala in late 2011. Both public and private laboratories were critical to test availability. The tests offered in point-of-care laboratories tended to be the most available tests. Prices of the most common tests ranged from $1.83-$3.46.

  19. Laboratory Diagnostics Market in East Africa: A Survey of Test Types, Test Availability, and Test Prices in Kampala, Uganda.

    Science.gov (United States)

    Schroeder, Lee F; Elbireer, Ali; Jackson, J Brooks; Amukele, Timothy K

    2015-01-01

    Diagnostic laboratory tests are routinely defined in terms of their sensitivity, specificity, and ease of use. But the actual clinical impact of a diagnostic test also depends on its availability and price. This is especially true in resource-limited settings such as sub-Saharan Africa. We present a first-of-its-kind report of diagnostic test types, availability, and prices in Kampala, Uganda. Test types (identity) and availability were based on menus and volumes obtained from clinical laboratories in late 2011 in Kampala using a standard questionnaire. As a measure of test availability, we used the Availability Index (AI). AI is the combined daily testing volumes of laboratories offering a given test, divided by the combined daily testing volumes of all laboratories in Kampala. Test prices were based on a sampling of prices collected in person and via telephone surveys in 2015. Test volumes and menus were obtained for 95% (907/954) of laboratories in Kampala city. These 907 laboratories offered 100 different test types. The ten most commonly offered tests in decreasing order were Malaria, HCG, HIV serology, Syphilis, Typhoid, Urinalysis, Brucellosis, Stool Analysis, Glucose, and ABO/Rh. In terms of AI, the 100 tests clustered into three groups: high (12 tests), moderate (33 tests), and minimal (55 tests) availability. 50% and 36% of overall availability was provided through private and public laboratories, respectively. Point-of-care laboratories contributed 35% to the AI of high availability tests, but only 6% to the AI of the other tests. The mean price of the most commonly offered test types was $2.62 (range $1.83-$3.46). One hundred different laboratory test types were in use in Kampala in late 2011. Both public and private laboratories were critical to test availability. The tests offered in point-of-care laboratories tended to be the most available tests. Prices of the most common tests ranged from $1.83-$3.46.

  20. A New Seamless Transfer Control Strategy of the Microgrid

    Directory of Open Access Journals (Sweden)

    Zhaoyun Zhang

    2014-01-01

    Full Text Available A microgrid may operate under two typical modes; the seamless transfer control of the microgrid is very important. The mode conversion controller is installed in microgrid and the control logic of master power is optimized for microgrid mode conversion. In the proposed scheme, master power is very important. The master-power is under the PQ control when microgrid is under grid-connected. And it is under V/F control when the microgrid is under islanding. The microgrid mode controller is used to solve the planned conversion. Three types of conversion are simulated in this paper. The simulation results show the correctness and validity of the mode control scheme. Finally, the implementation and application of the operation and control device are described.

  1. A new seamless transfer control strategy of the microgrid.

    Science.gov (United States)

    Zhang, Zhaoyun; Chen, Wei; Zhang, Zhe

    2014-01-01

    A microgrid may operate under two typical modes; the seamless transfer control of the microgrid is very important. The mode conversion controller is installed in microgrid and the control logic of master power is optimized for microgrid mode conversion. In the proposed scheme, master power is very important. The master-power is under the PQ control when microgrid is under grid-connected. And it is under V/F control when the microgrid is under islanding. The microgrid mode controller is used to solve the planned conversion. Three types of conversion are simulated in this paper. The simulation results show the correctness and validity of the mode control scheme. Finally, the implementation and application of the operation and control device are described.

  2. Data-driven modeling of solar-powered urban microgrids.

    Science.gov (United States)

    Halu, Arda; Scala, Antonio; Khiyami, Abdulaziz; González, Marta C

    2016-01-01

    Distributed generation takes center stage in today's rapidly changing energy landscape. Particularly, locally matching demand and generation in the form of microgrids is becoming a promising alternative to the central distribution paradigm. Infrastructure networks have long been a major focus of complex networks research with their spatial considerations. We present a systemic study of solar-powered microgrids in the urban context, obeying real hourly consumption patterns and spatial constraints of the city. We propose a microgrid model and study its citywide implementation, identifying the self-sufficiency and temporal properties of microgrids. Using a simple optimization scheme, we find microgrid configurations that result in increased resilience under cost constraints. We characterize load-related failures solving power flows in the networks, and we show the robustness behavior of urban microgrids with respect to optimization using percolation methods. Our findings hint at the existence of an optimal balance between cost and robustness in urban microgrids.

  3. On demand polarimetry using a movable microgrid polarizer

    Science.gov (United States)

    King, Page E.; Fest, Eric C.

    2015-09-01

    A movable pixelated filter array is proposed to provide low cost, on demand polarimetry and wavefront sensing. With this concept, an optical system can turn polarimetry on and off by using a shutter to move a microgrid polarizer array in and out of the optical path of the system. This allows an optical system to operate in two modes, a non-polarimetric mode in which sensor range is maintained, and a polarimetric mode in which it is reduced. In implementing this concept, adequate knowledge of the position of the filter in the optical path and calibration procedures become critical topics. This paper discusses simulated and hardware-tested results of this invention.

  4. Model Testing - Bringing the Ocean into the Laboratory

    DEFF Research Database (Denmark)

    Aage, Christian

    2000-01-01

    Hydrodynamic model testing, the principle of bringing the ocean into the laboratory to study the behaviour of the ocean itself and the response of man-made structures in the ocean in reduced scale, has been known for centuries. Due to an insufficient understanding of the physics involved, however......, the early model tests often gave incomplete or directly misleading results.This keynote lecture deals with some of the possibilities and problems within the field of hydrodynamic and hydraulic model testing....

  5. Finding neurosyphilis without the Venereal Disease Research Laboratory test.

    Science.gov (United States)

    MacLean, S; Luger, A

    1996-01-01

    The cerebrospinal fluid (CSF)-Venereal Disease Research Laboratory (VDRL) test is only 27% sensitive for diagnosing neurosyphilis. Discriminant analysis, used on 124 patients, shows that other commonly used laboratory tests can, in combination, identify 87% of patients with neurosyphilis with 94% specificity. The insensitivity of the CSF-VDRL (27% in persons with neurosyphilis) and the foreseen greater need to identify and treat neurosyphilis in the era of human immunodeficiency virus caused us to analyze the serum and cerebrospinal fluid results of 73 patients with syphilis and of 51 patients with clinically diagnosed neurosyphilis. Discriminant analysis was applied to different sets of laboratory tests to find the combination of test results best able to predict retrospectively the clinical diagnosis of syphilis or neurosyphilis, without reference to the CSF-VDRL. The predicting function averages 94% specificity and 87% sensitivity. Test result variables considered together are: CSF-FTA-ABS, serum FTA-ABS, CSF-TPHA, serum TPHA, and CSF cells. The authors conclude that clinicians or laboratories can, independently of the CSF-VDRL, compute a score showing whether the results of a set of commonly used tests suggest neurosyphilis in a patient.

  6. Quality performance of laboratory testing in pharmacies: a collaborative evaluation.

    Science.gov (United States)

    Zaninotto, Martina; Miolo, Giorgia; Guiotto, Adriano; Marton, Silvia; Plebani, Mario

    2016-11-01

    The quality performance and the comparability between results of pharmacies point-of-care-testing (POCT) and institutional laboratories have been evaluated. Eight pharmacies participated in the project: a capillary specimen collected by the pharmacist and, simultaneously, a lithium-heparin sample drawn by a physician of laboratory medicine for the pharmacy customers (n=106) were analyzed in the pharmacy and in the laboratory, respectively. Glucose, cholesterol, HDL-cholesterol, triglycerides, creatinine, uric acid, aspartate aminotransferase, alanine aminotransferase, were measured using: Reflotron, n=5; Samsung, n=1; Cardiocheck PA, n=1; Cholestech LDX, n=1 and Cobas 8000. The POCT analytical performance only (phase 2) were evaluated testing, in pharmacies and in the laboratory, the lithium heparin samples from a female drawn fasting daily in a week, and a control sample containing high concentrations of glucose, cholesterol and triglycerides. For all parameters, except triglycerides, the slopes showed a satisfactory correlation. For triglycerides, a median value higher in POCT in comparison to the laboratory (1.627 mmol/L vs. 0.950 mmol/L) has been observed. The agreement in the subjects classification, demonstrates that for glucose, 70% of the subjects show concentrations below the POCT recommended level (5.8-6.1 mmol/L), while 56% are according to the laboratory limit (pharmacies and specific criticisms in the pre- and post-analytical phases.

  7. Duplicated laboratory tests: evaluation of a computerized alert intervention abstract.

    Science.gov (United States)

    Bridges, Sharon A; Papa, Linda; Norris, Anne E; Chase, Susan K

    2014-01-01

    Redundant testing contributes to reductions in healthcare system efficiency. The purpose of this study was to: (1) determine if the use of a computerized alert would reduce the number and cost of duplicated Acute Hepatitis Profile (AHP) laboratory tests and (2) assess what patient, test, and system factors were associated with duplication. This study used a quasi-experimental pre- and post-test design to determine the proportion of duplication of the AHP test before and after implementation of a computerized alert intervention. The AHP test was duplicated if the test was requested again within 15 days of the initial test being performed and the result present in the medical record. The intervention consisted of a computerized alert (pop-up window) that indicated to the clinician that the test had recently been ordered. A total of 674 AHP tests were performed in the pre-intervention period and 692 in the postintervention group. In the pre-intervention period, 53 (7.9%) were duplicated and in postintervention, 18 (2.6%) were duplicated (ptests (p≤.001). Implementation of computerized alerts may be useful in reducing duplicate laboratory tests and improving healthcare system efficiency.

  8. Hereditary red cell membrane disorders and laboratory diagnostic testing.

    Science.gov (United States)

    King, M-J; Zanella, A

    2013-06-01

    This overview describes two groups of nonimmune hereditary hemolytic anemias caused by defects in membrane proteins located in distinct layers of the red cell membrane. Hereditary spherocytosis (HS), hereditary elliptocytosis (HE), and hereditary pyropoikilocytosis (HPP) represent disorders of the red cell cytoskeleton. Hereditary stomatocytoses represents disorders of cation permeability in the red cell membrane. The current laboratory screening tests for HS are the osmotic fragility test, acid glycerol lysis time test (AGLT), cryohemolysis test, and eosin-5'-maleimide (EMA)-binding test. For atypical HS, SDS-polyacrylamide gel electrophoresis of erythrocyte membrane proteins is carried out to confirm the diagnosis. The diagnosis of HE/HPP is based on abnormal red cell morphology and the detection of protein 4.1R deficiency or spectrin variants using gel electrophoresis. None of screening tests can detect all HS cases. Some testing centers (a survey of 25 laboratories) use a combination of tests (e.g., AGLT and EMA). No specific screening test for hereditary stomatocytoses is available. The preliminary diagnosis is based on presenting a compensated hemolytic anemia, macrocytosis, and a temperature or time dependent pseudohyperkalemia in some patients. Both the EMA-binding test and the osmotic fragility test may help in differential diagnosis of HS and hereditary stomatocytosis.

  9. Compendium of Test Results of Recent Single Event Effect Tests Conducted by the Jet Propulsion Laboratory

    Science.gov (United States)

    McClure, Steven S.; Allen, Gregory R.; Irom, Farokh; Scheick, Leif Z.; Adell, Philippe C.; Miyahira, Tetsuo F.

    2010-01-01

    This paper reports heavy ion and proton-induced single event effect (SEE) results from recent tests for a variety of microelectronic devices. The compendium covers devices tested over the last two years by the Jet Propulsion Laboratory.

  10. Generalities about design and operation of microgrids

    DEFF Research Database (Denmark)

    Rey-López, Juan Manuel; Vergara-Barrios, Pedro Pablo; Osma-Pinto, Germán Alfonso

    2015-01-01

    © The author; licensee Universidad Nacional de Colombia. The need for new generation systems has motivated the development of microgrids. This new concept may provide significant benefits such as losses reduction, high degree of efficiency and reliability to the transmission and distribution...... networks. This paper presents generalities about microgrids, including general structure and different topologies. Also an original methodology for facilitating its design and evaluation is proposed. Finally, the microgrid located at the Parque Tecnológíco de Guatiguará at the Universidad Industrial de...... Santander, is analyzed and an operation analysis is included for different operations stages of loads and generation, the performance of operation of storage systems, the interaction with the grid and an energy balance for all the system....

  11. Safety in the Chemical Laboratory: Tested Disposal Methods for Chemical Wastes from Academic Laboratories.

    Science.gov (United States)

    Armour, M. A.; And Others

    1985-01-01

    Describes procedures for disposing of dichromate cleaning solution, picric acid, organic azides, oxalic acid, chemical spills, and hydroperoxides in ethers and alkenes. These methods have been tested under laboratory conditions and are specific for individual chemicals rather than for groups of chemicals. (JN)

  12. Results of Laboratory Testing of Advanced Power Strips

    Energy Technology Data Exchange (ETDEWEB)

    Earle, L. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Sparn, B. [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2012-08-01

    Presented at the ACEEE Summer Study on Energy Efficiency in Buildings on August 12-17, 2012, this presentation reports on laboratory tests of 20 currently available advanced power strip products, which reduce wasteful electricity use of miscellaneous electric loads in buildings.

  13. Laboratory Test Setup for Cyclic Axially Loaded Piles in Sand

    DEFF Research Database (Denmark)

    Thomassen, Kristina; Ibsen, Lars Bo; Andersen, Lars Vabbersgaard

    2017-01-01

    conditions for all tests. For verifications purposes six static tension tests conducted at three different vertical effective stress levels of 0, 35 and 70 kPa. The load-displacement curves showed that the test setup provides repeatable test results. A preliminary comparison between the unit shaft friction......This paper presents a comprehensive description and the considerations regarding the design of a new laboratory test setup for testing cyclic axially loaded piles in sand. The test setup aims at analysing the effect of axial one-way cyclic loading on pile capacity and accumulated displacements....... Another aim was to test a large diameter pile segment with dimensions resembling full-scale piles to model the interface properties between pile and sand correctly. The pile segment was an open-ended steel pipe pile with a diameter of 0.5 m and a length of 1 m. The sand conditions resembled the dense sand...

  14. Verification and validation of diagnostic laboratory tests in clinical virology.

    Science.gov (United States)

    Rabenau, Holger F; Kessler, Harald H; Kortenbusch, Marhild; Steinhorst, Andreas; Raggam, Reinhard B; Berger, Annemarie

    2007-10-01

    This review summarizes major issues of verification and validation procedures and describes minimum requirements for verification and validation of diagnostic assays in clinical virology including instructions for CE/IVD-labeled as well as for self-developed ("home-brewed") tests or test systems. It covers techniques useful for detection of virus specific antibodies, for detection of viral antigens, for detection of viral nucleic acids, and for isolation of viruses on cell cultures in the routine virology laboratory.

  15. Atmospheric Renewable Energy Research, Volume 3: Solar-Power Microgrids and Atmospheric Influences

    Science.gov (United States)

    2016-09-01

    maximum ambient ( panel ) temperature of 25 °C. The solar photovoltaic (PV) panel would be mounted on a pole, and for maximum solar energy input, would...designers often use averaged azimuth and elevation angles for the panel orientation. This choice presumes the power system design is not constrained by...ARL-TR-7797 ● SEP 2016 US Army Research Laboratory Atmospheric Renewable Energy Research, Volume 3: Solar -Power Microgrids and

  16. Performance testing of radiobioassay laboratories: In vivo measurements, Final Report

    Energy Technology Data Exchange (ETDEWEB)

    MacLellan, J.A.; Traub, R.J.; Olsen, P.C.

    1990-04-01

    A study of two rounds of in vivo laboratory performance testing was undertaken by Pacific Northwest Laboratory (PNL) to determine the appropriateness of the in vivo performance criteria of draft American National Standards Institute (ANSI) standard ANSI N13.3, Performance Criteria for Bioassay.'' The draft standard provides guidance to in vivo counting facilities regarding the sensitivity, precision, and accuracy of measurements for certain categories of commonly assayed radionuclides and critical regions of the body. This report concludes the testing program by presenting the results of the Round Two testing. Testing involved two types of measurements: chest counting for radionuclide detection in the lung, and whole body counting for detection of uniformly distributed material. Each type of measurement was further divided into radionuclide categories as defined in the draft standard. The appropriateness of the draft standard criteria by measuring a laboratory's ability to attain them were judged by the results of both round One and Round Two testing. The testing determined that performance criteria are set at attainable levels, and the majority of in vivo monitoring facilities passed the criteria when complete results were submitted. 18 refs., 18 figs., 15 tabs.

  17. [Point-of-care-testing--the intensive care laboratory].

    Science.gov (United States)

    Müller, M M; Hackl, W; Griesmacher, A

    1999-01-01

    After successful centralization of laboratory analyses since more than 30 years, advances in biosensors, microprocessors, measurement of undiluted whole blood and miniaturization of laboratory analyzers are leading nowadays more and more to a re-decentralization in the laboratory medicine. Point-of-care-testing (POCT), which is defined as any laboratory test performed outside central or decentralized laboratories, is becoming more and more popular. The theoretical advantages of POCT are faster turn-around-times (TAT), more rapid medical decisions, avoidance of sample identification and sample transport problems and the need of only small specimen volumes. These advantages are frequently mentioned, but are not associated with a clear clinical benefit. The disadvantages of POCT such as incorrect handling and/or maintenance of the analyzers by nontrained clinical staff, inadequate or even absent calibrations and/or quality controls, lack of cost-effectiveness because of an increased number of analyzers and more expensive reagents, insufficient documentation and difficult comparability of the obtained POCT-results with routine laboratory results, are strongly evident. According to the authors' opinion the decision for the establishing of POCT has only to be made in a close co-operation between physicians and laboratorians in order to vouch for necessity and high quality of the analyses. Taking the local situation into consideration (24-h-central laboratory, etc.) the spectrum of parameters measured by means of POCT should be rigorously restricted to the vital functions. Such analytes should be: hemoglobin or hematocrit, activated whole blood clotting time, blood gases, sodium, potassium, ionized calcium, glucose, creatinine, ammonia and lactate.

  18. Control of Power Converters in AC Microgrids

    DEFF Research Database (Denmark)

    Rocabert, Joan; Luna, Alvaro; Blaabjerg, Frede

    2012-01-01

    The enabling of ac microgrids in distribution networks allows delivering distributed power and providing grid support services during regular operation of the grid, as well as powering isolated islands in case of faults and contingencies, thus increasing the performance and reliability of the ele......The enabling of ac microgrids in distribution networks allows delivering distributed power and providing grid support services during regular operation of the grid, as well as powering isolated islands in case of faults and contingencies, thus increasing the performance and reliability...

  19. Voltage control of DC islanded microgrids

    DEFF Research Database (Denmark)

    Tucci, Michele; Riverso, Stefano; Quintero, Juan Carlos Vasquez

    2015-01-01

    We propose a new decentralized control scheme for DC Islanded microGrids (ImGs) composed by several Distributed Generation Units (DGUs) with a general interconnection topology. Each local controller regulates to a reference value the voltage of the Point of Common Coupling (PCC) of the correspond......We propose a new decentralized control scheme for DC Islanded microGrids (ImGs) composed by several Distributed Generation Units (DGUs) with a general interconnection topology. Each local controller regulates to a reference value the voltage of the Point of Common Coupling (PCC...

  20. Containment testing for occupied and unoccupied laboratory chemical hoods

    Energy Technology Data Exchange (ETDEWEB)

    Greenley, P.L.; DiBerardinis, L.J.; Lorch, F.A.

    1999-07-01

    Containment of hazards in a laboratory chemical hood is based on the principle that air drawn through the face area of the hood is sufficient to overcome the many challenges at or near the opening. Challenges to overcome include, but are not limited to, air velocities near the hood, movement of the researcher, people walking past the hood, location of equipment inside the hood, size of the sash opening, and the shape and configuration of entrance conditions. To overcome these challenges, a sufficient face velocity must be maintained. Determining that proper face velocity must be maintained. Determining that proper face velocity for a given hood should be resolved by the system designer, facility safety officer, and researcher with these and other issues in mind. This research tests for containment at 100 feet per minute (fpm) face velocity on occupied hoods and tests the same hoods for containment at the reduced velocity of 60 fpm when unoccupied. Three laboratory chemical hoods of different sizes with several ash positions are used. The test results show that under ideal conditions in a test laboratory, an unoccupied hood (without a manikin) at 60 fpm contains as good as, if not better than, an occupied hood (with a manikin) at 100 fpm, as measured by the tracer gas tests specified in ANSI/ASHRAE 110-1995, Method of Testing Performance of Laboratory Fume Hoods (ASHRAE 1995). Further testing is needed to determine if this relationship is the same under conditions of actual use, i.e., cluttered hoods and presence of cross-drafts.

  1. Effects of a carbon tax on microgrid combined heat and power adoption

    Energy Technology Data Exchange (ETDEWEB)

    Siddiqui, Afzal S.; Marnay, Chris; Edwards, Jennifer L.; Firestone, Ryan M.; Ghosh, Srijay; Stadler, Michael

    2004-11-01

    This paper describes the economically optimal adoption and operation of distributed energy resources (DER) by a hypothetical California microgrid consisting of a group of commercial buildings over an historic test year, 1999. The optimization is conducted using a customer adoption model (DER-CAM) developed at Berkeley Lab and implemented in the General Algebraic Modeling System (GAMS). A microgrid is a semiautonomous grouping of electricity and heat loads interconnected to the existing utility grid (macrogrid) but able to island from it. The microgrid minimizes the cost of meeting its energy requirements (consisting of both electricity and heat loads) by optimizing the installation and operation of DER technologies while purchasing residual energy from the local combined natural gas and electricity utility. The available DER technologies are small-scale generators (< 500 kW), such as reciprocating engines, microturbines, and fuel cells, with or without combined heat and power (CHP) equipment, such as water and space heating and/or absorption cooling. By introducing a tax on carbon emissions, it is shown that if the microgrid is allowed to install CHP-enabled DER technologies, its carbon emissions are mitigated more than without CHP, demonstrating the potential benefits of small-scale CHP technology for climate change mitigation. Reciprocating engines with heat recovery and/or absorption cooling tend to be attractive technologies for the mild southern California climate, but the carbon mitigation tends to be modest compared to purchasing utility electricity because of the predominance of relatively clean central station generation in California.

  2. Characterization of mudrocks: a practical application of advanced laboratory testing

    Institute of Scientific and Technical Information of China (English)

    Richard J.JARDINE

    2011-01-01

    An integrated approach to geomaterial characterization is advocated that combines geology, in-situ testing, fabric studies, routine index experiments and advanced laboratory testing. It is shown that advanced laboratory testing can explore features such as kinematic yielding and anisotropy in stiffness or shear strength that would otherwise be impossible to quantify. A detailed study performed in London clay at the new Heathrow Terminal 5 site is used to illustrate the arguments made. It is shown that the London clay has strong anisotropy in stiffness, is highly non-linear over the strain range of engineering interest, has markedly anisotropic shear strength characteristics and exhibits a pronounced degree of brittleness. These features can impact significantly on the practical design and analysis of civil engineering works including shallow and deep foundations, tunnels and excavations, and the stability of slopes.

  3. Comparison of Recuperator Alloy Degradation in Laboratory and Engine Testing

    Energy Technology Data Exchange (ETDEWEB)

    Pint, Bruce A [ORNL; More, Karren Leslie [ORNL; Trejo, Rosa M [ORNL; Lara-Curzio, Edgar [ORNL

    2008-01-01

    In order to increase the efficiency of advanced microturbines, durable alloy foils are needed for their recuperators to operate at 650-700 C. Prior work has demonstrated that water vapor in the exhaust gas causes more rapid consumption of Cr from austenitic alloys, leading to a reduction in lifetime for the thin-walled components in this application. New commercial alloy foils are being tested in both laboratory tests in humid air and in the exhaust gas of a modified 60 kW microturbine. Initial results are presented for a commercial batch of 80 {micro}m alloy 120 foil. The Cr consumption rates in laboratory testing were similar to those observed in previous testing. The initial results from the microturbine indicate a faster Cr consumption rate compared to the laboratory test, but longer term results are needed to quantify the difference. These results will help to verify a Cr consumption model for predicting lifetimes in this environment based on classical gas transport theory.

  4. Identifying the Clinical Laboratory Tests from Unspecified "Other Lab Test" Data for Secondary Use.

    Science.gov (United States)

    Pan, Xuequn; Cimino, James J

    2015-01-01

    Clinical laboratory results are stored in electronic health records (EHRs) as structured data coded with local or standard terms. However, laboratory tests that are performed at outside laboratories are often simply labeled "outside test" or something similar, with the actual test name in a free-text result or comment field. After being aggregated into clinical data repositories, these ambiguous labels impede the retrieval of specific test results. We present a general multi-step solution that can facilitate the identification, standardization, reconciliation, and transformation of such test results. We applied our approach to data in the NIH Biomedical Translational Research Information System (BTRIS) to identify laboratory tests, map comment values to the LOINC codes that will be incorporated into our Research Entities Dictionary (RED), and develop a reference table that can be used in the EHR data extract-transform-load (ETL) process.

  5. Testing hygrometers used in cytogenetics laboratories for metaphase preparation.

    Science.gov (United States)

    Hartley, Thomas; Dun, Karen

    2011-07-01

    This protocol describes procedures for checking small laboratory hygrometers for accuracy at three relative humidity (rh) levels. The work arose out of the need to provide laboratory assessors with documentary evidence that the hygrometer used to monitor humidity in the vicinity of the laboratory where medical cytogenetics testing slides are prepared and dried in the ambient environment is reproducible and sufficiently accurate. The procedure is based upon the physicochemical principle that when water or certain saturated salt solutions are placed into a sealed environment, the humidity will equilibrate to well defined levels. We choose to check our hygrometers at three points: 95%, 75%, and 33% rh, using distilled water, saturated sodium chloride solution, and saturated magnesium chloride solution, respectively. Our results have demonstrated that the procedure is convenient and of sufficient accuracy to be fit for this annual hygrometer validation purpose. The procedure takes 24 hr per relative humidity point checked.

  6. Regulation of microgeneration and microgrids

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Paulo Moises [Escola Superior Tecnologia Viseu, Instituto Politecnico Viseu, Campus Politecnico Repeses, 3504-510 Viseu (Portugal); Matos, Manuel A.; Pecas Lopes, J.A. [INESC Porto, Faculdade de Engenharia da Universidade do Porto, Porto (Portugal)

    2008-10-15

    The concept of microgrid ({mu}Grid) has been emerging as a way to integrate microgeneration ({mu}G) in low-voltage (LV) networks and simultaneously improve its potential benefits. Technical requirements to connect {mu}grids to LV networks have been studied in order to make this concept technologically feasible and safe to operate. However, the regulatory framework for economic integration of {mu}G and {mu}Grids on distribution systems, despite being crucial, is still an open issue. The main purpose of this paper is to contribute for the development of an appropriate economic regulation framework that removes the barriers to {mu}G and {mu}Grid development. To do so, the relevant costs and benefits resulting from the establishment of {mu}G and {mu}Grid are identified and a methodology for sharing those costs and benefits among the involved economic agents is presented. The only pre-requisite of such a methodology is the existence of a net benefit to all economic agents. (author)

  7. Regulation of microgeneration and microgrids

    Energy Technology Data Exchange (ETDEWEB)

    Moises Costa, Paulo [Escola Superior Tecnologia Viseu, Instituto Politecnico Viseu, Campus Politecnico Repeses, 3504-510 Viseu (Portugal)], E-mail: paulomoises@elect.estv.ipv.pt; Matos, Manuel A.; Pecas Lopes, J.A. [INESC Porto, Faculdade de Engenharia da Universidade do Porto, Porto (Portugal)

    2008-10-15

    The concept of microgrid ({mu}Grid) has been emerging as a way to integrate microgeneration ({mu}G) in low-voltage (LV) networks and simultaneously improve its potential benefits. Technical requirements to connect {mu}grids to LV networks have been studied in order to make this concept technologically feasible and safe to operate. However, the regulatory framework for economic integration of {mu}G and {mu}Grids on distribution systems, despite being crucial, is still an open issue. The main purpose of this paper is to contribute for the development of an appropriate economic regulation framework that removes the barriers to {mu}G and {mu}Grid development. To do so, the relevant costs and benefits resulting from the establishment of {mu}G and {mu}Grid are identified and a methodology for sharing those costs and benefits among the involved economic agents is presented. The only pre-requisite of such a methodology is the existence of a net benefit to all economic agents.

  8. Oral fluid for workplace drug testing: laboratory implementation.

    Science.gov (United States)

    Moore, Christine

    2012-02-01

    As oral fluid increases in popularity for workplace testing, due to its easy and observed collection, the ability to adapt existing laboratory instrumentation without further capital investment will allow more facilities to test oral fluid. The European Workplace Drug Testing Society (EWDTS) guidelines for oral fluid testing outline the maximum cut-off concentrations acceptable under the workplace drug testing programme. The recommended cut-off values may be subject to change as advances in technology or other considerations warrant identification of these substances at different concentrations; however, the instrumentation currently exists for routine screening using immunoassay and confirmation by gas chromatography-mass spectrometry (GC-MS) or liquid chromatography with tandem mass spectral detection (LC-MS/MS) so laboratories can easily implement oral fluid analysis in their current systems. Immunoassays for the detection of the drug classes at recommended levels have been developed using various collection devices and different formats: liquid reagent chemistries and enzyme-linked immunosorbent assay (ELISA) platforms. Immunoassays provide faster turnaround than mass spectral methods particularly when the number of specimens increases. Since the guidelines state that positive immunoassay results should not be reported without confirmation, fully validated methods using LC-MS/MS and/or GC-MS for all drugs are also widely available. All proposed concentrations are easily achievable using MS instruments currently in testing laboratories; however, the likelihood of a low number of positive specimens in workplace populations allows the test facility to screen specimens in a cost-effective manner using immunoassay, while ensuring scientific credibility and defensibility by confirming the positive results with a second test. Copyright © 2011 John Wiley & Sons, Ltd.

  9. 49 CFR 40.81 - What laboratories may be used for DOT drug testing?

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 1 2010-10-01 2010-10-01 false What laboratories may be used for DOT drug testing... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.81 What laboratories may be used for DOT drug testing? (a) As a drug testing laboratory located in the U.S., you are...

  10. Microgrid Stability Controller Based on Adaptive Robust Total SMC

    DEFF Research Database (Denmark)

    Su, Xiaoling; Han, Minxiao; Guerrero, Josep M.

    2015-01-01

    and mathematical models of the MSC indicate that the system is inherently nonlinear and time-variable. Therefore, this paper proposes an adaptive robust total sliding-mode control (ARTSMC) system for the MSC. It is proved that the ARTSMC system is insensitive to parametric uncertainties and external disturbances......This paper presents a microgrid stability controller (MSC) in order to provide existing DGs the additional functionality of working in islanding mode without changing their control strategies in grid-connected mode and to enhance the stability of the microgrid. Microgrid operating characteristics....... The MSC provides fast dynamic response and robustness to the microgrid. When the system is operating in grid-connected mode, it is able to improve the controllability of the exchanged power between the microgrid and the utility grid, while smoothing DG’s output power. When the microgrid is operating...

  11. Inflammatory bowel diseases: from pathogenesis to laboratory testing.

    Science.gov (United States)

    Basso, Daniela; Zambon, Carlo-Federico; Plebani, Mario

    2014-04-01

    Inflammatory bowel diseases (IBDs), which comprise the two major clinical subtypes, Crohn's disease and ulcerative colitis, incur high morbidity and potential mortality. The present study reviews data on the pathogenesis and diagnosis of IBDs. The pathogenesis depends on complex interactions between susceptibility genes, environmental factors, and innate and adaptive immunity, the understanding of which is crucial to discovering novel laboratory biomarkers. Traditional laboratory tests for the diagnosis, prognosis and assessment of disease activity of IBDs are reported on, and the biochemical properties, pre-analytical and analytical aspects and clinical utility of the fecal markers lactoferrin and calprotectin are described. DNA testing and established (ASCA and pANCA) and emerging (ACCA, ALCA, AMCA, OmpC) serum markers are described; a further aspect to be addressed is the clinical use of pharmacogenetics for the treatment of IBDs.

  12. Review on Control of DC Microgrids

    DEFF Research Database (Denmark)

    Meng, Lexuan; Shafiee, Qobad; Ferrari-Trecate, Giancarlo

    2017-01-01

    This paper performs an extensive review on control schemes and architectures applied to DC microgrids. It covers multi-layer hierarchical control schemes, coordinated control strategies, plug-and-play operations, stability and active damping aspects as well as nonlinear control algorithms. Island...

  13. Power flow control of intertied ac microgrids

    DEFF Research Database (Denmark)

    Nutkani, Inam Ullah; Loh, Poh Chiang; Blaabjerg, Frede

    2013-01-01

    of interlinking power converters. Active and reactive power flows of these converters should preferably be managed autonomously without demanding for fast communication links. A scheme that can fulfill the objectives is now proposed, which upon realised, will result in more robustly integrated microgrids...

  14. A Micro-Grid Battery Storage Management

    DEFF Research Database (Denmark)

    Mahat, Pukar; Escribano Jiménez, Jorge; Moldes, Eloy Rodríguez

    2013-01-01

    systems under its administration. This paper presents an optimized scheduling of a micro-grid battery storage system that takes into account the next-day forecasted load and generation profiles and spot electricity prices. Simulation results show that the battery system can be scheduled close to optimal...

  15. Weld Tests Conducted by the Idaho National Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Larry Zirker; Lance Lauerhass; James Dowalo

    2007-02-01

    During the fiscal year of 2006, the Idaho National Laboratory (INL) performed many tests and work relating to the Mobile Melt-Dilute (MMD) Project components. Tests performed on the Staubli quick disconnect fittings showed promising results, but more tests were needed validate the fittings. Changes were made to the shield plug design—reduced the closure groove weld depth between the top of the canister and the top plate of the shielding plug from 0.5-in to 0.375-in deep. Other changes include a cap to cover the fitting, lifting pintle and welding code citations on the prints. Tests conducted showed stainless steel tubing, with 0.25-in, 0.375-in, and 0.5-in diameters, all with 0.035-in wall thickness, could be pinch seal welded using commercially available resistance welding equipment. Subsequent testing showed that these welds could be real-time inspected with ultrasonic inspection methods.

  16. Federal laboratory nondestructive testing research and development applicable to industry

    Energy Technology Data Exchange (ETDEWEB)

    Smith, S.A.; Moore, N.L.

    1987-02-01

    This document presents the results of a survey of nondestructive testing (NDT) and related sensor technology research and development (R and D) at selected federal laboratories. Objective was to identify and characterize NDT activities that could be applied to improving energy efficiency and overall productivity in US manufacturing. Numerous federally supported R and D programs were identified in areas such as acoustic emissions, eddy current, radiography, computer tomography and ultrasonics. A Preliminary Findings Report was sent to industry representatives, which generated considerable interest.

  17. TESTING OF THE RADBALL TECHNOLOGY AT SAVANNAH RIVER NATIONAL LABORATORY

    Energy Technology Data Exchange (ETDEWEB)

    Farfan, E.; Foley, T.

    2010-02-10

    The United Kingdom's National Nuclear Laboratory (NNL) has developed a remote, nonelectrical, radiation-mapping device known as RadBall (patent pending), which offers a means to locate and quantify radiation hazards and sources within contaminated areas of the nuclear industry. Positive results from initial deployment trials in nuclear waste reprocessing plants at Sellafield in the United Kingdom and the anticipated future potential use of RadBall throughout the U.S. Department of Energy Complex have led to the NNL partnering with the Savannah River National Laboratory (SRNL) to further test, underpin, and strengthen the technical performance of the technology. The study completed at SRNL addresses key aspects of the testing of the RadBall technology. The first set of tests was performed at Savannah River Nuclear Solutions Health Physics Instrument Calibration Laboratory (HPICL) using various gamma-ray sources and an x-ray machine with known radiological characteristics. The objective of these preliminary tests was to identify the optimal dose and collimator thickness. The second set of tests involved a highly contaminated hot cell. The objective of this testing was to characterize a hot cell with unknown radiation sources. The RadBall calibration experiments and hot cell deployment were successful in that for each trial radiation tracks were visible. The deployment of RadBall can be accomplished in different ways depending on the size and characteristics of the contaminated area (e.g., a hot cell that already has a crane/manipulator available or highly contaminated room that requires the use of a remote control device with sensor and video equipment to position RadBall). This report also presents SRNL-designed RadBall accessories for future RadBall deployment (a harness, PODS, and robot).

  18. Microgrid management architecture considering optimal battery dispatch

    Science.gov (United States)

    Paul, Tim George

    Energy management and economic operation of microgrids with energy storage systems at the distribution level have attracted significant research interest in recent years. One of the challenges in this area has been the coordination of energy management functions with decentralized and centralized dispatch. In this thesis a distributed dispatch algorithm for a microgrid consisting of a photovoltaic source with energy storage which can work with a centralized dispatch algorithm that ensure stability of the microgrid is proposed. To this end, first a rule based dispatch algorithm is formulated which is based on maximum resource utilization and can work in both off grid and grid connected mode. Then a fixed horizon optimization algorithm which minimizes the cost of power taken from the grid is developed. In order to schedule the battery based on changes in the PV farm a predictive horizon methodology based optimization is designed. Further, the rule based and optimization based dispatch methodologies is linked to optimize the voltage deviations at the microgrid Point of Common Coupling (PCC). The main advantage of the proposed method is that, an optimal active power dispatch considering the nominal voltage bandwidth can be initiated for the microgrid in both grid connected or off grid mode of operation. Also, the method allows the grid operator to consider cost based optimal renewable generation scheduling and/or the maximum power extraction based modes of operation simultaneously or separately based on grid operating conditions and topologies. Further, the methods allows maintaining PCC voltage within the limits during these modes of operation and at the same time ensure that the battery dispatch is optimal.

  19. LABORATORY TESTING OF LEICA AT401 LASER TRACKER

    Directory of Open Access Journals (Sweden)

    Filip Dvořáček

    2016-04-01

    Full Text Available This paper describes laboratory tests on a Leica AT401laser tracker. As the newer Leica AT402 model also uses the same firmware package, most of the results should also be valid for this device. First, we present the instrument’s firmware errors and the software used for testing. The ASME B89.4.19-2006 standard for testing laser trackers is briefly presented. The warm-up effect of the instrument is inspected with respect to both angle measurement and distance measurement. The absolute distance meter (ADM is compared with a laboratory interferometer on a 30-meter long rail and also on a bench with automated movement of the carriage of the reflector. A time series of measurements for determining the additive constant is evaluated. A simple test of the stability of the distance measurement in field conditions is introduced. Most of the tests were carried out at the Research Institute of Geodesy, Topography and Cartography (RIGTC and at the Faculty of Civil Engineering (FCE of the Czech Technical University in Prague (CTU.

  20. Mobile Energy Laboratory energy-efficiency testing programs

    Energy Technology Data Exchange (ETDEWEB)

    Parker, G.B.; Currie, J.W.

    1991-09-01

    This report summarizes energy-efficiency testing activities applying the Mobile Energy Laboratory (MEL) testing capabilities during the first and second quarters of fiscal year (FY) 1991. The MELs, developed by the US Department of Energy (DOE) Federal Energy Management Program (FEMP), are administered by Pacific Northwest Laboratory (PNL) and the Naval Energy and Environmental Support Activity (NEESA) for energy testing and energy conservation program support functions at federal facilities. The using agencies principally fund MEL applications, while DOE/FEMP funds program administration and capability enhancement activities. This report fulfills the requirements established in Section 8 of the MEL Use Plan (PNL-6861) for semiannual reporting on energy-efficiency testing activities using the MEL capabilities. The MEL Use Committee, formally established in 1989, developed the MEL Use Plan and meets semiannually to establish priorities for energy-efficient testing applications using the MEL capabilities. The MEL Use Committee is composed of one representative each of the US Department of Energy, US Army, US Air Force, US Navy, and other federal agencies.

  1. Autonomous Operation of Hybrid Microgrid With AC and DC Subgrids

    DEFF Research Database (Denmark)

    Chiang Loh, Poh; Li, Ding; Kang Chai, Yi

    2013-01-01

    This paper investigates on power-sharing issues of an autonomous hybrid microgrid. Unlike existing microgrids which are purely ac, the hybrid microgrid studied here comprises dc and ac subgrids interconnected by power electronic interfaces. The main challenge here is to manage power flows among all...... sources distributed throughout the two types of subgrids, which is certainly tougher than previous efforts developed for only ac or dc microgrid. This wider scope of control has not yet been investigated, and would certainly rely on the coordinated operation of dc sources, ac sources, and interlinking...

  2. Customized electric power storage device for inclusion in a microgrid

    Energy Technology Data Exchange (ETDEWEB)

    Goldsmith, Steven Y.; Wilson, David; Robinett, III, Rush D.

    2017-08-01

    An electric power storage device included in a microgrid is described herein. The electric power storage device has at least one of a charge rate, a discharge rate, or a power retention capacity that has been customized for the microgrid. The at least one of the charge rate, the discharge rate, or the power retention capacity of the electric power storage device is computed based at least in part upon specified power source parameters in the microgrid and specified load parameters in the microgrid.

  3. Microgrid Design Toolkit (MDT) Technical Documentation and Component Summaries

    Energy Technology Data Exchange (ETDEWEB)

    Arguello, Bryan [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Gearhart, Jared Lee [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Jones, Katherine A. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Eddy, John P. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-09-01

    The Microgrid Design Toolkit (MDT) is a decision support software tool for microgrid designers to use during the microgrid design process. The models that support the two main capabilities in MDT are described. The first capability, the Microgrid Sizing Capability (MSC), is used to determine the size and composition of a new microgrid in the early stages of the design process. MSC is a mixed-integer linear program that is focused on developing a microgrid that is economically viable when connected to the grid. The second capability is focused on refining a microgrid design for operation in islanded mode. This second capability relies on two models: the Technology Management Optimization (TMO) model and Performance Reliability Model (PRM). TMO uses a genetic algorithm to create and refine a collection of candidate microgrid designs. It uses PRM, a simulation based reliability model, to assess the performance of these designs. TMO produces a collection of microgrid designs that perform well with respect to one or more performance metrics.

  4. Overview of Multi-DC-Bus Solutions for DC Microgrids

    DEFF Research Database (Denmark)

    Ricchiuto, D.; Mastromauro, R.A.; Liserre, Marco;

    2013-01-01

    DC Microgrids have recently received a lot of attention in the last years due to high penetration of renewable energy sources as well as distributed energy storage systems. In the future DC microgrids could be preferable respect to AC microgrids in terms of redundancy since multi-DC-Bus solutions...... could provide a continuative power supply to the loads. An overview of Multi-DC-Bus solutions is presented in this paper. The performances are compared on the basis of possible DC microgrid configurations, redundancy, different DC voltage levels....

  5. Optimal Power Scheduling for an Islanded Hybrid Microgrid

    DEFF Research Database (Denmark)

    Hernández, Adriana Carolina Luna; Aldana, Nelson Leonardo Diaz; Savaghebi, Mehdi

    2016-01-01

    A microgrid is a system that integrates energy generation, energy storage, and loads and it is able to operate either in interconnected or islanded mode. Energy resources should be scheduled to supply the load properly in order to coordinate optimally the power exchange within the microgrid...... according to a defined objective function. In this paper, an optimal power scheduling for generation and demand side is presented to manage an islanded hybrid PV-wind-battery microgrid implemented in Shanghai-China. The optimization is addressed through a Mixed-Integer Linear Programming (MILP) mathematical......SPACE1006) in which a scaled down model of this microgrid is emulated....

  6. The LINC-NIRVANA fringe and flexure tracker: laboratory tests

    Science.gov (United States)

    Tremou, Evangelia; Eckart, Andreas; Horrobin, Matthew; Lindhorst, Bettina; Moser, Lydia; Rost, Steffen; Smajic, Semir; Straubmeier, Christian; Wank, Imke; Zuther, Jens; Bertram, Thomas

    2010-07-01

    LINC-NIRVANA is the NIR homothetic imaging camera for the Large Binocular Telescope (LBT). In close cooperation with the Adaptive Optics systems of LINC-NIRVANA the Fringe and Flexure Tracking System (FFTS) is a fundamental component to ensure a complete and time-stable wavefront correction at the position of the science detector in order to allow for long integration times at interferometric angular resolutions. In this contribution, we present the design and the realization of the ongoing FFTS laboratory tests, taking into account the system requirements. We have to sample the large Field of View and to follow the reference source during science observations to an accuracy of less than 2 microns. In particular, important tests such as cooling tests of cryogenic components and tip - tilt test (the repeatability and the precision under the different inclinations) are presented. The system parameters such as internal flexure and precision are discussed.

  7. Fault Detection and Location by Static Switches in Microgrids Using Wavelet Transform and Adaptive Network-Based Fuzzy Inference System

    Directory of Open Access Journals (Sweden)

    Ying-Yi Hong

    2014-04-01

    Full Text Available Microgrids are a highly efficient means of embedding distributed generation sources in a power system. However, if a fault occurs inside or outside the microgrid, the microgrid should be immediately disconnected from the main grid using a static switch installed at the secondary side of the main transformer near the point of common coupling (PCC. The static switch should have a reliable module implemented in a chip to detect/locate the fault and activate the breaker to open the circuit immediately. This paper proposes a novel approach to design this module in a static switch using the discrete wavelet transform (DWT and adaptive network-based fuzzy inference system (ANFIS. The wavelet coefficient of the fault voltage and the inference results of ANFIS with the wavelet energy of the fault current at the secondary side of the main transformer determine the control action (open or close of a static switch. The ANFIS identifies the faulty zones inside or outside the microgrid. The proposed method is applied to the first outdoor microgrid test bed in Taiwan, with a generation capacity of 360.5 kW. This microgrid test bed is studied using the real-time simulator eMegaSim developed by Opal-RT Technology Inc. (Montreal, QC, Canada. The proposed method based on DWT and ANFIS is implemented in a field programmable gate array (FPGA by using the Xilinx System Generator. Simulation results reveal that the proposed method is efficient and applicable in the real-time control environment of a power system.

  8. Evidence-based laboratory medicine - a guide for critical evaluation of in vitro laboratory testing.

    Science.gov (United States)

    Christenson, Robert H

    2007-03-01

    Evidence-based laboratory medicine (EBLM) is an essential part of modern laboratory medicine practice. This review presents a guide for better understanding and implementing the EBLM process. The process of EBLM begins with development of a clinically relevant question. Tools for assisting in question formulation include the Patient Intervention Comparator and Outcome (PICO) or Case Assay Predicate and Outcome (CAPO) strategies. Locating evidence that addresses the question is performed using resources available on the internet. Systematic reviews that have objectively collated evidence addressing the question can be particularly useful. The evidence collected must be critically appraised using checklists developed for this purpose. Diagnostic performance of tests is frequently stated in terms of sensitivity, specificity, negative and positive predictive values, and the diagnostic odds ratio. Evaluating 95% confidence limits is important for interpretation. Likelihood ratios for tests in disease states are also important for converting pre-test probabilities to post-test probabilities using Bayes Theorem. Tools such as Receiver Operator Characteristic curves and Fagan's diagram are important analytical and visual aids. Laboratorians must give thoughtful consideration into conveying information to clinicians in a useful format. Evidence-based guidelines and collaboration with clinicians are important for development of local care paths. Auditing the effectiveness of implemented care paths is an important part of quality management. In conclusion, effective use of EBLM can benefit patients by helping laboratorians provide the best-available information in the clinically relevant time frame. Presenting the information appropriately maximizes clinical application of the best evidence.

  9. Application of flexible scope in large testing laboratories

    Directory of Open Access Journals (Sweden)

    Carina Di Candia

    2011-04-01

    Full Text Available According as the international definition of Flexible Scope, a laboratory must demonstrate face with the accreditation body that it has the knowledge, experience and competence to work within the full range of its flexible scope, as well as possessing suitable laboratory environments and equipment. The laboratory must also demonstrate that it has a management system in place that can control its proposed approach while continuing to comply with the requirements of ISO 17025:2005. In case of UKAS (Unites Kingdom Accreditation Service, prior to offering accreditation for flexible scope they must have a high degree of confidence that the staff are technically competent and that the management system controlling certain key processes as development, review, validation and authorization.LATU apply these requirements since 2004 as "Unified Tests". Until this date, LATU was doing the same type of tests in different materials departments using different equipment, personal, and testing quality control. In order to that were defined cross disciplinary groups to analyze this topic approaching in personal competence and quality control tests improvement, and resource's decrease. For example, LATU has the Unified Test Tensile Strength accredited by UKAS in: corrugated and solid fiberboard, paper board, linerboard, cork plugs, plastic bags, plastic sheeting, paper, woven fabrics, plastic woven bags and woven plastic. As a result of the Unified Tests was generated a general unified manage procedure with unified criteria's, responsibilities and actions. Was written a unique testing procedure not only with the actual flexible scope and the flexibilities limits but also the compliance requirements of ISO 17025 and the accreditations body methodology. We could decrease the amount of documentation to control. Was defined the methodology and implemented periodicaly internal inter comparisons between departments in order to valid the unified tests and has a unique

  10. The Role of Laboratory Tests in Crohn’s Disease

    Science.gov (United States)

    Cappello, Maria; Morreale, Gaetano Cristian

    2016-01-01

    In the past, laboratory tests were considered of limited value in Crohn’s disease (CD). In the era of biologics, laboratory tests have become essential to evaluate the inflammatory burden of the disease (C-reactive protein, fecal calprotectin) since symptoms-based scores are subjective, to predict the response to pharmacological options and the risk of relapse, to discriminate CD from ulcerative colitis, to select candidates to anti-tumor necrosis factors [screening tests looking for hepatitis B virus and hepatitis C virus status and latent tuberculosis], to assess the risk of adverse events (testing for thiopurine metabolites and thiopurine-methyltransferase activity), and to personalize and optimize therapy (therapeutic drug monitoring). Pharmacogenetics, though presently confined to the assessment of thiopurineme methyltransferase polymorphisms and hematological toxicity associated with thiopurine treatment, is a promising field that will contribute to a better understanding of the molecular mechanisms of the variability in response to the drugs used in CD with the attempt to expand personalized care and precision medicine strategies. PMID:27656094

  11. Laboratory testing for cobalamin deficiency in megaloblastic anemia.

    Science.gov (United States)

    Oberley, Matthew J; Yang, David T

    2013-06-01

    Cobalamin (vitamin B12) deficiency is a common cause of megaloblastic anemia in Western populations. Laboratory evaluation of megaloblastic anemia frequently includes the assessment of patient cobalamin and folate status. Current total serum cobalamin measurements are performed in the clinical laboratory with competitive binding luminescence assays, whose results may not always accurately reflect actual cobalamin stores. Surrogate markers of cobalamin deficiency such as methylmalonic acid and homocysteine have been utilized to improve diagnostic accuracy; however, the specificity of these tests by themselves is rather low. Measurement of the biologically active fraction of cobalamin, holotranscobalamin, has been proposed as a replacement for current total cobalamin assays. Although holotranscobalamin measurements appear to have slighter better sensitivity, the specificity of this assay remains to be determined. The relative merits and demerits of commonly available methods to assess cobalamin deficiency in patients with suspected megaloblastic anemia are discussed. Copyright © 2013 Wiley Periodicals, Inc.

  12. Black holes a laboratory for testing strong gravity

    CERN Document Server

    Bambi, Cosimo

    2017-01-01

    This textbook introduces the current astrophysical observations of black holes, and discusses the leading techniques to study the strong gravity region around these objects with electromagnetic radiation. More importantly, it provides the basic tools for writing an astrophysical code and testing the Kerr paradigm. Astrophysical black holes are an ideal laboratory for testing strong gravity. According to general relativity, the spacetime geometry around these objects should be well described by the Kerr solution. The electromagnetic radiation emitted by the gas in the inner part of the accretion disk can probe the metric of the strong gravity region and test the Kerr black hole hypothesis. With exercises and examples in each chapter, as well as calculations and analytical details in the appendix, the book is especially useful to the beginners or graduate students who are familiar with general relativity while they do not have any background in astronomy or astrophysics.

  13. Microgrid Design Toolkit (MDT) User Guide Software v1.2.

    Energy Technology Data Exchange (ETDEWEB)

    Eddy, John P. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-08-01

    The Microgrid Design Toolkit (MDT) supports decision analysis for new ("greenfield") microgrid designs as well as microgrids with existing infrastructure. The current version of MDT includes two main capabilities. The first capability, the Microgrid Sizing Capability (MSC), is used to determine the size and composition of a new, grid connected microgrid in the early stages of the design process. MSC is focused on developing a microgrid that is economically viable when connected to the grid. The second capability is focused on designing a microgrid for operation in islanded mode. This second capability relies on two models: the Technology Management Optimization (TMO) model and Performance Reliability Model (PRM).

  14. How to test NISP instrument for EUCLID mission in laboratory

    Science.gov (United States)

    Costille, A.; Carle, Michael; Fabron, Christophe; Prieto, Eric; Beaumont, Florent; Jessen, Niels-Christian; Jakobsen, Peter; Sørensen, Anton N.; Andersen, Michael I.; Grupp, Frank; Maciaszek, Thierry; Ealet, Anne; Gillard, William; Clemens, Jean-Claude

    2016-07-01

    The ESA mission Euclid is designed to explore the dark side of the Universe. The NISP (Near Infrared Spectro- Photometer) is one of its two instruments operating in the near-IR spectral region (0.9-2μm), that will be fully integrated and tested at Laboratory d'Astrophysique de Marseille (LAM) under vacuum and thermal conditions. The test campaign will regroup functional tests, performance tests, calibration procedure validation and observations scenario test. One of the main objectives of the test campaign will be the measurement of the focus position of NISP with respect to the EUCLID object plane. To achieve these tests campaign, a global Ground Support Equipment (GSE) called the Verification Ground System (VGS) has to be developed. It will be a complex set of GSE integrated in ERIOS chamber made of: a telescope simulator to simulate the EUCLID telescope and to inject light into NISP, a thermal environment to be used for NISP thermal balance and verification, a sets of mechanical interfaces to align all the parts into ERIOS chamber, the NISP Electrical GSE (EGSE) to control the instrument during the test and a metrology system to measure the positions of the components during the test. We will present the preliminary design and concepts of the VGS and we will show the main difficulties we have to deal with: design of thermal environment at 80K with 4mK stability, the development of a metrology system in vacuum, knowledge of the focus position within 150μm in cold, etc. The main objectives of the NISP test will be explained and how the VGS responds to the test requirement.

  15. Digital Audio Radio Broadcast Systems Laboratory Testing Nearly Complete

    Science.gov (United States)

    2005-01-01

    Radio history continues to be made at the NASA Lewis Research Center with the completion of phase one of the digital audio radio (DAR) testing conducted by the Consumer Electronics Group of the Electronic Industries Association. This satellite, satellite/terrestrial, and terrestrial digital technology will open up new audio broadcasting opportunities both domestically and worldwide. It will significantly improve the current quality of amplitude-modulated/frequency-modulated (AM/FM) radio with a new digitally modulated radio signal and will introduce true compact-disc-quality (CD-quality) sound for the first time. Lewis is hosting the laboratory testing of seven proposed digital audio radio systems and modes. Two of the proposed systems operate in two modes each, making a total of nine systems being tested. The nine systems are divided into the following types of transmission: in-band on-channel (IBOC), in-band adjacent-channel (IBAC), and new bands. The laboratory testing was conducted by the Consumer Electronics Group of the Electronic Industries Association. Subjective assessments of the audio recordings for each of the nine systems was conducted by the Communications Research Center in Ottawa, Canada, under contract to the Electronic Industries Association. The Communications Research Center has the only CCIR-qualified (Consultative Committee for International Radio) audio testing facility in North America. The main goals of the U.S. testing process are to (1) provide technical data to the Federal Communication Commission (FCC) so that it can establish a standard for digital audio receivers and transmitters and (2) provide the receiver and transmitter industries with the proper standards upon which to build their equipment. In addition, the data will be forwarded to the International Telecommunications Union to help in the establishment of international standards for digital audio receivers and transmitters, thus allowing U.S. manufacturers to compete in the

  16. Energy management and multi-layer control of networked microgrids

    Science.gov (United States)

    Zamora, Ramon

    Networked microgrids is a group of neighboring microgrids that has ability to interchange power when required in order to increase reliability and resiliency. Networked microgrid can operate in different possible configurations including: islanded microgrid, a grid-connected microgrid without a tie-line converter, a grid-connected microgrid with a tie-line converter, and networked microgrids. These possible configurations and specific characteristics of renewable energy offer challenges in designing control and management algorithms for voltage, frequency and power in all possible operating scenarios. In this work, control algorithm is designed based on large-signal model that enables microgrid to operate in wide range of operating points. A combination between PI controller and feed-forward measured system responses will compensate for the changes in operating points. The control architecture developed in this work has multi-layers and the outer layer is slower than the inner layer in time response. The main responsibility of the designed controls are to regulate voltage magnitude and frequency, as well as output power of the DG(s). These local controls also integrate with a microgrid level energy management system or microgrid central controller (MGCC) for power and energy balance for. the entire microgrid in islanded, grid-connected, or networked microgid mode. The MGCC is responsible to coordinate the lower level controls to have reliable and resilient operation. In case of communication network failure, the decentralized energy management will operate locally and will activate droop control. Simulation results indicate the superiority of designed control algorithms compared to existing ones.

  17. Antifungal susceptibility testing method for resource constrained laboratories

    Directory of Open Access Journals (Sweden)

    Khan S

    2006-01-01

    Full Text Available Purpose: In resource-constrained laboratories of developing countries determination of antifungal susceptibility testing by NCCLS/CLSI method is not always feasible. We describe herein a simple yet comparable method for antifungal susceptibility testing. Methods: Reference MICs of 72 fungal isolates including two quality control strains were determined by NCCLS/CLSI methods against fluconazole, itraconazole, voriconazole, amphotericin B and cancidas. Dermatophytes were also tested against terbinafine. Subsequently, on selection of optimum conditions, MIC was determined for all the fungal isolates by semisolid antifungal agar susceptibility method in Brain heart infusion broth supplemented with 0.5% agar (BHIA without oil overlay and results were compared with those obtained by reference NCCLS/CLSI methods. Results: Comparable results were obtained by NCCLS/CLSI and semisolid agar susceptibility (SAAS methods against quality control strains. MICs for 72 isolates did not differ by more than one dilution for all drugs by SAAS. Conclusions: SAAS using BHIA without oil overlay provides a simple and reproducible method for obtaining MICs against yeast, filamentous fungi and dermatophytes in resource-constrained laboratories.

  18. Retrofitting Combined Space and Water Heating Systems. Laboratory Tests

    Energy Technology Data Exchange (ETDEWEB)

    Schoenbauer, B. [NorthernStar Building America Partnership, St. Paul, MN (United States); Bohac, D. [NorthernStar Building America Partnership, St. Paul, MN (United States); Huelman, P. [NorthernStar Building America Partnership, St. Paul, MN (United States); Olsen, R. [NorthernStar Building America Partnership, St. Paul, MN (United States); Hewett, M. [NorthernStar Building America Partnership, St. Paul, MN (United States)

    2012-10-01

    Better insulated and tighter homes can often use a single heating plant for both space and domestic water heating. These systems, called dual integrated appliances (DIA) or combination systems, can operate at high efficiency and eliminate combustion safety issues associated by using a condensing, sealed combustion heating plant. Funds were received to install 400 DIAs in Minnesota low-income homes. The NorthernSTAR DIA laboratory was created to identify proper system components, designs, operating parameters, and installation procedures to assure high efficiency of field installed systems. Tests verified that heating loads up to 57,000 Btu/hr can be achieved with acceptable return water temperatures and supply air temperatures.

  19. Retrofitting Combined Space and Water Heating Systems: Laboratory Tests

    Energy Technology Data Exchange (ETDEWEB)

    Schoenbauer, B.; Bohac, D.; Huelman, P.; Olson, R.; Hewitt, M.

    2012-10-01

    Better insulated and tighter homes can often use a single heating plant for both space and domestic water heating. These systems, called dual integrated appliances (DIA) or combination systems, can operate at high efficiency and eliminate combustion safety issues associated by using a condensing, sealed combustion heating plant. Funds were received to install 400 DIAs in Minnesota low-income homes. The NorthernSTAR DIA laboratory was created to identify proper system components, designs, operating parameters, and installation procedures to assure high efficiency of field installed systems. Tests verified that heating loads up to 57,000 Btu/hr can be achieved with acceptable return water temperatures and supply air temperatures.

  20. Laboratory tests for disorders of complement and complement regulatory proteins.

    Science.gov (United States)

    Shih, Angela R; Murali, Mandakolathur R

    2015-12-01

    The complement pathway is a cascade of proteases that is involved in immune surveillance and innate immunity, as well as adaptive immunity. Dysfunction of the complement cascade may be mediated by aberrations in the pathways of activation, complement regulatory proteins, or complement deficiencies, and has been linked to a number of hematologic disorders, including paroxysmal noctural hemoglobinuria (PNH), hereditary angioedema (HAE), and atypical hemolytic-uremic syndrome (aHUS). Here, current laboratory tests for disorders of the complement pathway are reviewed, and their utility and limitations in hematologic disorders and systemic diseases are discussed. Current therapeutic advances targeting the complement pathway in treatment of complement-mediated hematologic disorders are also reviewed.

  1. Prototype dish testing and analysis at Sandia National Laboratories

    Science.gov (United States)

    Grossman, J. W.; Houser, R. M.; Erdman, W. W.

    1991-12-01

    During the past year, Sandia National Laboratories performed on-sun testing of several dish concentrator concepts. These tests were undertaken at the National Solar Thermal Test Facility (NSTTF). Two of the tests were performed in support of the DOE Concentrator Receiver Development Program. The first was on-sun testing of the single-element stretched-membrane dish; this 7-meter diameter dish uses a single preformed metal membrane with an aluminized polyester optical surface and shows potential for future dish-Stirling systems. The next involved two prototype facets from the Faceted Stretched-Membrane Dish Program. These facets, representing competitive design concepts, are closest to commercialization. Five 1-meter triangular facets were tested on-sun as part of the development program for a solar dynamic system on Space Station Freedom. While unique in character, all the tests utilized the Beam Characterization System (BCS) as the main measurement tool and all were analyzed using the Sandia-developed CIRCE2 computer code. The BCS is used to capture and digitize an image of the reflected concentrator beam that is incident on a target surface. The CIRCE2 program provides a computational tool, which when given the geometry of the concentrator and target as well as other design parameters will predict the flux distribution of the reflected beam. One of these parameters, slope error, is the variable that has a major effect in determining the quality of the reflected beam. The methodology used to combine these two tools to predict uniform slope errors for the dishes is discussed in this document. As the Concentrator Development Programs continue, Sandia will test and evaluate two prototype dish systems. The first, the faceted stretched-membrane dish, is expected to be tested in 1992, followed by the full-scale single-element stretched-membrane dish in 1993. These tests will use the tools and methodology discussed in this document.

  2. Diagnostic criteria and laboratory tests for disseminated intravascular coagulation.

    Science.gov (United States)

    Wada, Hideo; Matsumoto, Takeshi; Hatada, Tuyoshi

    2012-12-01

    Three diagnostic criteria for disseminated intravascular coagulation (DIC) have been established by the Japanese Ministry of Health, Labor and Welfare, the International Society on Thrombosis and Hemostasis (ISTH) and the Japanese Association for Acute Medicine. The diagnostic criteria involving global coagulation tests, such as the Japanese Ministry of Health, Labor and Welfare criteria and the ISTH overt diagnostic criteria, are first-generation DIC diagnostic criteria, those involving global coagulation tests and changes in these tests such as the Japanese Association for Acute Medicine criteria, are second-generation DIC diagnostic criteria, and those including non-overt DIC diagnostic criteria involving global coagulation tests, changes in these tests and hemostatic molecular markers will be the future (third-generation) DIC diagnostic criteria. There are no significant differences in the three diagnostic criteria with respect to predicting poor outcomes. Therefore, the third generation of diagnostic criteria including hemostatic molecular markers is expected to be established. Standardization and the determination of adequate cutoff values should be required for each laboratory test.

  3. Control of hybrid AC/DC microgrid under islanding operational conditions

    DEFF Research Database (Denmark)

    Ding, G.; Gao, F.; Zhang, S.

    2014-01-01

    This paper presents control methods for hybrid AC/DC microgrid under islanding operation condition. The control schemes for AC sub-microgrid and DC sub-microgrid are investigated according to the power sharing requirement and operational reliability. In addition, the key control schemes......, the whole hybrid AC/DC microgrid can manage the power flow transferred between sub-microgrids for improving on the operational quality and efficiency....

  4. Laboratory Testing of Waste Isolation Pilot Plant Surrogate Waste Materials

    Science.gov (United States)

    Broome, S.; Bronowski, D.; Pfeifle, T.; Herrick, C. G.

    2011-12-01

    The Waste Isolation Pilot Plant (WIPP) is a U.S. Department of Energy geological repository for the permanent disposal of defense-related transuranic (TRU) waste. The waste is emplaced in rooms excavated in the bedded Salado salt formation at a depth of 655 m below the ground surface. After emplacement of the waste, the repository will be sealed and decommissioned. WIPP Performance Assessment modeling of the underground material response requires a full and accurate understanding of coupled mechanical, hydrological, and geochemical processes and how they evolve with time. This study was part of a broader test program focused on room closure, specifically the compaction behavior of waste and the constitutive relations to model this behavior. The goal of this study was to develop an improved waste constitutive model. The model parameters are developed based on a well designed set of test data. The constitutive model will then be used to realistically model evolution of the underground and to better understand the impacts on repository performance. The present study results are focused on laboratory testing of surrogate waste materials. The surrogate wastes correspond to a conservative estimate of the degraded containers and TRU waste materials after the 10,000 year regulatory period. Testing consists of hydrostatic, uniaxial, and triaxial tests performed on surrogate waste recipes that were previously developed by Hansen et al. (1997). These recipes can be divided into materials that simulate 50% and 100% degraded waste by weight. The percent degradation indicates the anticipated amount of iron corrosion, as well as the decomposition of cellulosics, plastics, and rubbers. Axial, lateral, and volumetric strain and axial and lateral stress measurements were made. Two unique testing techniques were developed during the course of the experimental program. The first involves the use of dilatometry to measure sample volumetric strain under a hydrostatic condition. Bulk

  5. Battery Test Facility- Electrochemical Analysis and Diagnostics Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — The Electrochemical Analysis and Diagnostics Laboratory (EADL) provides battery developers with reliable, independent, and unbiased performance evaluations of their...

  6. Black Start Strategy for PV-ESS Multi-Microgrids with Three-Phase/Single-Phase Architecture

    Directory of Open Access Journals (Sweden)

    Zhirong Xu

    2016-05-01

    Full Text Available With the rapid development of microgrids (MGs in recent years, it is anticipated that combinations of multiple microgrids—multi-microgrids (MMGs—will gradually become a new form of power grid. A safe and efficient black start strategy for MMGs is in urgent demand because of their complicated structure and control systems. In this paper, first, we analyze the topology and control system of residential-type MMGs with three-phase/single-phase (TP/SP architecture. Second, a black start strategy based on a hierarchical control scheme is presented, including the selection strategy for the main power supply and master microgrid, the stand-alone operation strategy, and the grid-connected operation strategy. After the selection of the main power supplies, the master MG is determined. Hereby, all sub-microgrids (SMGs execute the stand-alone algorithm. When the synchronous connection condition is satisfied, the slave SMGs connect to the master MG who provides the voltage and frequency support. Meanwhile, the control algorithm transfers to the grid-connected algorithm, with the grid dispatching value set to zero. Finally, experimental results from the MMG experimental setup in the Clean Energy Technology Laboratory (CETLAB are presented to verify the effectiveness and feasibility of the proposed black start strategy.

  7. Implementation and Control of a Residential Electrothermal Microgrid Based on Renewable Energies, a Hybrid Storage System and Demand Side Management

    Directory of Open Access Journals (Sweden)

    Julio Pascual

    2014-01-01

    Full Text Available This paper proposes an energy management strategy for a residential electrothermal microgrid, based on renewable energy sources. While grid connected, it makes use of a hybrid electrothermal storage system, formed by a battery and a hot water tank along with an electrical water heater as a controllable load, which make possible the energy management within the microgrid. The microgrid emulates the operation of a single family home with domestic hot water (DHW consumption, a heating, ventilation and air conditioning (HVAC system as well as the typical electric loads. An energy management strategy has been designed which optimizes the power exchanged with the grid profile in terms of peaks and fluctuations, in applications with high penetration levels of renewables. The proposed energy management strategy has been evaluated and validated experimentally in a full scale residential microgrid built in our Renewable Energy Laboratory, by means of continuous operation under real conditions. The results show that the combination of electric and thermal storage systems with controllable loads is a promising technology that could maximize the penetration level of renewable energies in the electric system.

  8. Wind-driven SEIG supplying DC microgrid through a single-stage power converter

    Directory of Open Access Journals (Sweden)

    Vellapatchi Nayanar

    2016-09-01

    Full Text Available Nowadays, there is an increased emphasis on utilizing the renewable energy sources and selection of suitable power converters for supplying dc microgrid. Among the various renewable energy sources, wind energy stands first in terms of installed capacity. So, an attempt is made in this paper for supplying dc microgrid utilizing wind energy. A self-excited induction generator has been used in the proposed wind energy conversion system (WECS. A single-stage power converter, namely, semi-converter is connected between the SEIG and dc grid terminals for closed-loop control of the proposed system. A perturb and observe (P&O based maximum power point tracking (MPPT algorithm has been developed and implemented using a dsPIC30F4011 digital controller. In this MPPT algorithm, the firing angle of the converter is adjusted by continuously monitoring the dc grid current for a given wind velocity. For analyzing the proposed system, a MATLAB/Simulink model has been developed by selecting the various components starting from wind-turbine model to the power converter supplying dc microgrid. Successful working of the proposed WECS has also been shown through experimental results obtained on a prototype model developed in the laboratory.

  9. Results from laboratory and field testing of nitrate measuring spectrophotometers

    Science.gov (United States)

    Snazelle, Teri T.

    2015-01-01

    Five ultraviolet (UV) spectrophotometer nitrate analyzers were evaluated by the U.S. Geological Survey (USGS) Hydrologic Instrumentation Facility (HIF) during a two-phase evaluation. In Phase I, the TriOS ProPs (10-millimeter (mm) path length), Hach NITRATAX plus sc (5-mm path length), Satlantic Submersible UV Nitrate Analyzer (SUNA, 10-mm path length), and S::CAN Spectro::lyser (5-mm path length) were evaluated in the HIF Water-Quality Servicing Laboratory to determine the validity of the manufacturer's technical specifications for accuracy, limit of linearity (LOL), drift, and range of operating temperature. Accuracy specifications were met in the TriOS, Hach, and SUNA. The stock calibration of the S::CAN required two offset adjustments before the analyzer met the manufacturer's accuracy specification. Instrument drift was observed only in the S::CAN and was the result of leaching from the optical path insert seals. All tested models, except for the Hach, met their specified LOL in the laboratory testing. The Hach's range was found to be approximately 18 milligrams nitrogen per liter (mg-N/L) and not the manufacturer-specified 25 mg-N/L. Measurements by all of the tested analyzers showed signs of hysteresis in the operating temperature tests. Only the SUNA measurements demonstrated excessive noise and instability in temperatures above 20 degrees Celsius (°C). The SUNA analyzer was returned to the manufacturer at the completion of the Phase II field deployment evaluation for repair and recalibration, and the performance of the sensor improved significantly.

  10. Cost-Prioritized Droop Schemes for Autonomous AC Microgrids

    DEFF Research Database (Denmark)

    Nutkani, Inam Ullah; Loh, Poh Chiang; Wang, Peng

    2015-01-01

    This paper presents two cost-prioritized droop sche- mes for distributed generators (DGs) in a rural or islanded microgrid. Dispatch prioritization of the schemes allows autonomous identification of the appropriate DGs for generation, in accordance to the overall load conditions of the microgrid....

  11. Continuously Optimized Reliable Energy (CORE) Microgrid: Models & Tools (Fact Sheet)

    Energy Technology Data Exchange (ETDEWEB)

    2013-07-01

    This brochure describes Continuously Optimized Reliable Energy (CORE), a trademarked process NREL employs to produce conceptual microgrid designs. This systems-based process enables designs to be optimized for economic value, energy surety, and sustainability. Capabilities NREL offers in support of microgrid design are explained.

  12. Agent-Based Decentralized Control Method for Islanded Microgrids

    DEFF Research Database (Denmark)

    Li, Qiang; Chen, Feixiong; Chen, Minyou;

    2016-01-01

    In this paper, an agent-based decentralized control model for islanded microgrids is proposed, which consists of a two-layer control structure. The bottom layer is the electrical distribution microgrid, while the top layer is the communication network composed of agents. An agent is regarded as a...

  13. Feasibility study on small modular reactors for modern microgrids

    Energy Technology Data Exchange (ETDEWEB)

    Islam, R.; Gabbar, H.A., E-mail: hossam.gabbar@uoit.ca [Univ. of Ontario Inst. of Technology, Faculty of Energy Systems and Nuclear Science, Oshawa, Ontario (Canada)

    2013-07-01

    Microgrid is a solution of conventional power grid problem and offer sustainable decentralized power system. Microgrid with modern distributed energy resources (DER) could play an important role to alleviate dependency on the main electricity grid. Distributed energy resource comprises wind turbine, solar photovoltaic, diesel generator, gas engine, micro turbine, fuel cells, etc.Due to the gap between typical loads and supply within microgrid, larger scale energy generation could provide a possible solution to balance power demand and supply. Feasibility study of Small Nuclear Power Plant, such as Small Modular reactor (SMR), within microgrids could be achieved via different cases. To achieve the target, a comprehensive feasibility study is conducted on microgrid with SMR through electricity generation profiles, geographical and environmental assessment, as well as cost analysis using simulation practices and data analysis.Also potency of SMRs is analyzed. Parameters and Key Performance Indicators (KPIs) could be analyzed to achieve feasible solution of microgrids with small modular reactor (SMR) to improve the overall microgrid performance.The study shows that SMR could be a feasible solution if microgrid parameters are selected properly. (author)

  14. SMART FUEL CELL OPERATED RESIDENTIAL MICRO-GRID COMMUNITY

    Energy Technology Data Exchange (ETDEWEB)

    Dr. Mohammad S. Alam (PI/PD)

    2005-04-13

    To build on the work of year one by expanding the smart control algorithm developed to a micro-grid of ten houses; to perform a cost analysis; to evaluate alternate energy sources; to study system reliability; to develop the energy management algorithm, and to perform micro-grid software and hardware simulations.

  15. Stochastic Modeling and Optimization in a Microgrid: A Survey

    Directory of Open Access Journals (Sweden)

    Hao Liang

    2014-03-01

    Full Text Available The future smart grid is expected to be an interconnected network of small-scale and self-contained microgrids, in addition to a large-scale electric power backbone. By utilizing microsources, such as renewable energy sources and combined heat and power plants, microgrids can supply electrical and heat loads in local areas in an economic and environment friendly way. To better adopt the intermittent and weather-dependent renewable power generation, energy storage devices, such as batteries, heat buffers and plug-in electric vehicles (PEVs with vehicle-to-grid systems can be integrated in microgrids. However, significant technical challenges arise in the planning, operation and control of microgrids, due to the randomness in renewable power generation, the buffering effect of energy storage devices and the high mobility of PEVs. The two-way communication functionalities of the future smart grid provide an opportunity to address these challenges, by offering the communication links for microgrid status information collection. However, how to utilize stochastic modeling and optimization tools for efficient, reliable and economic planning, operation and control of microgrids remains an open issue. In this paper, we investigate the key features of microgrids and provide a comprehensive literature survey on the stochastic modeling and optimization tools for a microgrid. Future research directions are also identified.

  16. SINGLE EVENT EFFECTS TEST FACILITY AT OAK RIDGE NATIONAL LABORATORY

    Energy Technology Data Exchange (ETDEWEB)

    Riemer, Bernie [ORNL; Gallmeier, Franz X [ORNL; Dominik, Laura J [ORNL

    2015-01-01

    Increasing use of microelectronics of ever diminishing feature size in avionics systems has led to a growing Single Event Effects (SEE) susceptibility arising from the highly ionizing interactions of cosmic rays and solar particles. Single event effects caused by atmospheric radiation have been recognized in recent years as a design issue for avionics equipment and systems. To ensure a system meets all its safety and reliability requirements, SEE induced upsets and potential system failures need to be considered, including testing of the components and systems in a neutron beam. Testing of ICs and systems for use in radiation environments requires the utilization of highly advanced laboratory facilities that can run evaluations on microcircuits for the effects of radiation. This paper provides a background of the atmospheric radiation phenomenon and the resulting single event effects, including single event upset (SEU) and latch up conditions. A study investigating requirements for future single event effect irradiation test facilities and developing options at the Spallation Neutron Source (SNS) is summarized. The relatively new SNS with its 1.0 GeV proton beam, typical operation of 5000 h per year, expertise in spallation neutron sources, user program infrastructure, and decades of useful life ahead is well suited for hosting a world-class SEE test facility in North America. Emphasis was put on testing of large avionics systems while still providing tunable high flux irradiation conditions for component tests. Makers of ground-based systems would also be served well by these facilities. Three options are described; the most capable, flexible, and highest-test-capacity option is a new stand-alone target station using about one kW of proton beam power on a gas-cooled tungsten target, with dual test enclosures. Less expensive options are also described.

  17. Power Oscillations Damping in DC Microgrids

    DEFF Research Database (Denmark)

    Hamzeh, Mohsen; Ghafouri, Mohsen; Karimi, Houshang

    2016-01-01

    This paper proposes a new control strategy for damping of power oscillations in a multi-source dc microgrid. A parallel combination of a fuel cell (FC), a photovoltaic (PV) system and a supercapacitor (SC) are used as a hybrid power conversion system (HPCS). The SC compensates for the slow...... transient response of the FC stack. The HPCS controller comprises a multi-loop voltage controller and a virtual impedance loop for power management. The virtual impedance loop uses a dynamic droop gain to actively damp the low-frequency oscillations of the power sharing control unit. The gain of virtual...... impedance loop is determined using small signal analysis and pole placement method. The Mesh analysis is employed to further study the stability of low-frequency modes of the overall dc microgrid. Moreover, based on the guardian map theorem, a robust stability analysis is carried out to determine...

  18. Voltage and Current Regulators Design of Power Converters in Islanded Microgrids based on State Feedback Decoupling

    DEFF Research Database (Denmark)

    Federico, de Bosio; de Sousa Ribeiro, Luiz Antonio; Freijedo Fernandez, Francisco Daniel

    2016-01-01

    In stand-alone microgrids based on voltage source inverters state feedback coupling between the capacitor voltage and inductor current degrades significantly the dynamics performance of voltage and current regulators. The decoupling of the controlled states is proposed, considering the limitations...... introduced by system delays. Moreover, a proportional resonant voltage controller is designed according to Nyquist criterion taking into account application requirements. Experimental tests performed in compliance with the UPS standards verify the theoretical analysis....

  19. Economic energy distribution and consumption in a microgrid Part 2

    DEFF Research Database (Denmark)

    Tahersima, Fatemeh; Stoustrup, Jakob; Andersen, Palle

    2014-01-01

    Energy management of a small scale electrical microgrid is investigated. The microgrid comprises residential houses with local renewable generation, consumption and storage units. The microgrid has the possibility of connection to the electricity grid as well to compensate energy decit of local...... power producers. The nal objective is to full the microgrid's energy demands mainly from the local electricity producers. The other objective is to manage power consumption such that the consumption cost is minimum for individual households. In this study, a hierarchical controller composed of three...... levels is proposed. Each layer from bottom to top focus on individual energy consuming units, individual buildings, and the microgrid respectively. At the middle layer, a model predictive controller is formulated to schedule the building's energy consumption using potential load exibilities. The top...

  20. Laboratory Performance Testing of Residential Window Air Conditioners

    Energy Technology Data Exchange (ETDEWEB)

    Winkler, J.; Booten, C.; Christensen, D.; Tomerlin, J.

    2013-03-01

    Window air conditioners are the dominant cooling product for residences, in terms of annual unit sales. They are inexpensive, portable and can be installed by the owner. For this reason, they are an attractive solution for supplemental cooling, for retrofitting air conditioning into a home which lacks ductwork, and for renters. Window air conditioners for sale in the United States are required to meet very modest minimum efficiency standards. Four window air conditioners' performance were tested in the Advanced HVAC Systems Laboratory on NREL's campus in Golden, CO. In order to separate and study the refrigerant system's performance, the unit's internal leakage pathways, the unit's fanforced ventilation, and the leakage around the unit resulting from installation in a window, a series of tests were devised that focused on each aspect of the unit's performance. These tests were designed to develop a detailed performance map to determine whole-house performance in different climates. Even though the test regimen deviated thoroughly from the industry-standard ratings test, the results permit simple calculation of an estimated rating for both capacity and efficiency that would result from a standard ratings test. Using this calculation method, it was found that the three new air conditioners' measured performance was consistent with their ratings. This method also permits calculation of equivalent SEER for the test articles. Performance datasets were developed across a broad range of indoor and outdoor operating conditions, and used them to generate performance maps.

  1. Microgrids: Energy management by loss minimization technique

    Directory of Open Access Journals (Sweden)

    A. K. Basu, S. Chowdhury, S.P. Chowdhury

    2011-03-01

    Full Text Available Energy management is a techno-economic issue, which dictates, in the context of microgrids, how optimal investment in technology front could bring optimal power quality and reliability (PQR of supply to the consumers. Investment in distributed energy resources (DERs, with their connection to the utility grid at optimal locations and with optimal sizes, saves energy in the form of line loss reduction. Line loss reduction is the indirect benefit to the microgrid owner who may recover it as an incentive from utility. The present paper focuses on planning of optimal siting and sizing of DERs based on minimization of line loss. Optimal siting is done, here, on the loss sensitivity index (LSI method and optimal sizing by differential evolution (DE algorithms, which is, again, compared with particle swarm optimization (PSO technique. Studies are conducted on 6-bus and 14-bus radial networks under islanded mode of operation with electric demand profile. Islanding helps planning of DER capacity of microgrid, which is self-sufficient to cater its own consumers without utility’s support.

  2. EVA Development and Verification Testing at NASA's Neutral Buoyancy Laboratory

    Science.gov (United States)

    Jairala, Juniper C.; Durkin, Robert; Marak, Ralph J.; Sipila, Stepahnie A.; Ney, Zane A.; Parazynski, Scott E.; Thomason, Arthur H.

    2012-01-01

    As an early step in the preparation for future Extravehicular Activities (EVAs), astronauts perform neutral buoyancy testing to develop and verify EVA hardware and operations. Neutral buoyancy demonstrations at NASA Johnson Space Center's Sonny Carter Training Facility to date have primarily evaluated assembly and maintenance tasks associated with several elements of the International Space Station (ISS). With the retirement of the Shuttle, completion of ISS assembly, and introduction of commercial players for human transportation to space, evaluations at the Neutral Buoyancy Laboratory (NBL) will take on a new focus. Test objectives are selected for their criticality, lack of previous testing, or design changes that justify retesting. Assembly tasks investigated are performed using procedures developed by the flight hardware providers and the Mission Operations Directorate (MOD). Orbital Replacement Unit (ORU) maintenance tasks are performed using a more systematic set of procedures, EVA Concept of Operations for the International Space Station (JSC-33408), also developed by the MOD. This paper describes the requirements and process for performing a neutral buoyancy test, including typical hardware and support equipment requirements, personnel and administrative resource requirements, examples of ISS systems and operations that are evaluated, and typical operational objectives that are evaluated.

  3. Standard test method for laboratory evaluation of magnesium sacrificial anode test specimens for underground applications

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1997-01-01

    1.1 This test method covers a laboratory procedure that measures the two fundamental performance properties of magnesium sacrificial anode test specimens operating in a saturated calcium sulfate, saturated magnesium hydroxide environment. The two fundamental properties are electrode (oxidation potential) and ampere hours (Ah) obtained per unit mass of specimen consumed. Magnesium anodes installed underground are usually surrounded by a backfill material that typically consists of 75 % gypsum (CaSO4·2H2O), 20 % bentonite clay, and 5 % sodium sulfate (Na2SO4). The calcium sulfate, magnesium hydroxide test electrolyte simulates the long term environment around an anode installed in the gypsum-bentonite-sodium sulfate backfill. 1.2 This test method is intended to be used for quality assurance by anode manufacturers or anode users. However, long term field performance properties may not be identical to property measurements obtained using this laboratory test. Note 1—Refer to Terminology G 15 for terms used ...

  4. Laboratory Testing of Active and Passive UHF RFID Tags

    Directory of Open Access Journals (Sweden)

    Kolarovszki Peter

    2016-06-01

    Full Text Available This article deals with research of laboratory testing by active and passive UHF tags and therefore mutual coexistence of active and passive RFID technology, which is a part of automatic identification and data capture. In this article we would like to describe an identification of transport unit based on passive technology and also by active technology. We would like to specify, how this technologies can work together and in which application focuses on postal and logistics. All results are verified by measurement in our AIDC laboratory, which is located at the University of Žilina. Our research contains different types of measurements in order to point out the possible influence of these two technologies. The results of our research bring the new point of view and indicate the ways using of UHF RFID technology in postal and logistics applications. At the end of this article is characterized the utilization of the RFID technology in postal logistics chain by using both passive and active technologies.

  5. Laboratory tests of oil spreading under the ice cover

    Energy Technology Data Exchange (ETDEWEB)

    Rytkoenen, J.; Liukkonen, S.; Riipi, T. [VTT Manufacturing Technology, Espoo (Finland)

    1998-07-01

    A laboratory study on oil spreading and drifting under ice was conducted by VTT Manufacturing Technology, Finland. The aim of the study was to find out threshold conditions for the oil movement under ice. The oil was released under ice in calm water and the spreading of the oil slick under the bottom of the ice was investigated. In the oil drifting part, oil drifting velocities under level ice in steady water flow, water flow velocities making oil to submerge from open water to under ice and water velocities making oil to escape from under ice ridges were studied. This paper describes the oil spreading part of the study. The study included four types of oil, namely the fresh and pre-altered North Sea Brent crude oil, lubrication oil and diesel fuel oil. All the measurements were taken in water under ice, thus at the temperature of zero Celcius. In the level ice studies, three different ice bottom roughnesses were tested. (author)

  6. Test and Validation of the Mars Science Laboratory Robotic Arm

    Science.gov (United States)

    Robinson, M.; Collins, C.; Leger, P.; Kim, W.; Carsten, J.; Tompkins, V.; Trebi-Ollennu, A.; Florow, B.

    2013-01-01

    The Mars Science Laboratory Robotic Arm (RA) is a key component for achieving the primary scientific goals of the mission. The RA supports sample acquisition by precisely positioning a scoop above loose regolith or accurately preloading a percussive drill on Martian rocks or rover-mounted organic check materials. It assists sample processing by orienting a sample processing unit called CHIMRA through a series of gravity-relative orientations and sample delivery by positioning the sample portion door above an instrument inlet or the observation tray. In addition the RA facilitates contact science by accurately positioning the dust removal tool, Alpha Particle X-Ray Spectrometer (APXS) and the Mars Hand Lens Imager (MAHLI) relative to surface targets. In order to fulfill these seemingly disparate science objectives the RA must satisfy a variety of accuracy and performance requirements. This paper describes the necessary arm requirement specification and the test campaign to demonstrate these requirements were satisfied.

  7. Sandia National Laboratories' new high level acoustic test facility

    Energy Technology Data Exchange (ETDEWEB)

    Rogers, J. D.; Hendrick, D. M.

    1989-01-01

    A high intensity acoustic test facility has been designed and is under construction at Sandia National Laboratories in Albuquerque, NM. The chamber is designed to provide an acoustic environment of 154dB (re 20 {mu}Pa) overall sound pressure level over the bandwidth of 50 Hz to 10,000 Hz. The chamber has a volume of 16,000 cubic feet with interior dimensions of 21.6 ft {times} 24.6 ft {times} 30 ft. The construction of the chamber should be complete by the summer of 1990. This paper discusses the design goals and constraints of the facility. The construction characteristics are discussed in detail, as are the acoustic performance design characteristics. The authors hope that this work will help others in designing acoustic chambers. 12 refs., 6 figs.

  8. Confidence Intervals for Laboratory Sonic Boom Annoyance Tests

    Science.gov (United States)

    Rathsam, Jonathan; Christian, Andrew

    2016-01-01

    Commercial supersonic flight is currently forbidden over land because sonic booms have historically caused unacceptable annoyance levels in overflown communities. NASA is providing data and expertise to noise regulators as they consider relaxing the ban for future quiet supersonic aircraft. One deliverable NASA will provide is a predictive model for indoor annoyance to aid in setting an acceptable quiet sonic boom threshold. A laboratory study was conducted to determine how indoor vibrations caused by sonic booms affect annoyance judgments. The test method required finding the point of subjective equality (PSE) between sonic boom signals that cause vibrations and signals not causing vibrations played at various amplitudes. This presentation focuses on a few statistical techniques for estimating the interval around the PSE. The techniques examined are the Delta Method, Parametric and Nonparametric Bootstrapping, and Bayesian Posterior Estimation.

  9. Evidence of sulphonamide residues by rapid laboratory test

    Directory of Open Access Journals (Sweden)

    Damir Kaša

    2004-04-01

    Full Text Available In addition to the significant role in the treatment of bacterial diseases, primarily mastitis, intestinal infections and pneumonia, sulphonamides are used as fodder additives. The disadvantage of antimicrobial therapy in dairy cows is the residue presence, of biologically active substances, in milk and milk products. The purpose of this paper is to control milk for sulphonamide residues in relation to the amounts as permitted by the Regulations (OfficialGazette of the Republic of Croatia No. 39/2003. To determine sulphonamides, the laboratory test LabSULFAmilk, manufactured by Frank analab d.o.o., was used. Positive reaction to sulphonamide residues was found in 10 % of the examined samples.

  10. The use of laboratory tests in the diagnosis of SLE.

    Science.gov (United States)

    Egner, W

    2000-06-01

    ANA IIF is an effective screening assay in patients with clinical features of SLE and will detect most anti-ssDNA, anti-dsDNA, ENAs, and other autoantibodies. False positives are common. The clinical importance cannot be extrapolated from the ANA titre or pattern, although higher titres (> 1/160) are more likely to be important. HEp-2 cells are the most sensitive substrate for ANA detection, but this must be balanced against an increased incidence of insignificant positivity. ANA positive samples should be subjected to more specific assays for the diagnosis of SLE. A combination of ENA (Ro/La/Sm/RNP) and dsDNA assays will detect most patients with SLE as long as the characteristics of the assays used are well understood. ESR and CRP measurements provide useful additional information. Sjogren's syndrome and MCTD will produce overlapping serology with SLE, and anti-dsDNA titres are sometimes seen in autoimmune hepatitis and rheumatoid arthritis. All results should be reported in the light of the clinical details, by an experienced immunologist. A suggested diagnostic protocol is outlined in fig 1. The type of assay used crucially influences the predictive value of the tests. ELISA technology dominates routine laboratory practice, but tends to produce more false positive and true weak positive results, which may reduce the PPV of the test. This can be minimised by using IgG specific conjugates and careful assay validation. The NPV for SLE [figure: see text] is high for most assays but the PPV varies. Where necessary, laboratories should use crithidia or Farr dsDNA assays to confirm dubious ELISA dsDNA results, and ID/IB to confirm dubious ENA results. For monitoring, a precise, quantitative assay is required. It is unclear whether the detection of IgM or low affinity antibodies has a role here. A combination of anti-dsDNA, C3, C4, CRP, and ESR assays provides the most useful clinical information. Anti-ssDNA assays are likely to be useful, and are potentially more

  11. Smart Microgrid Energy Management Controls for Improved Energy Efficiency and Renewables Integration at DoD Installations

    Science.gov (United States)

    2013-04-01

    Oct 2010 • “Microgrid Technologies – 29 Palms – Distribution Optimization in Smart Grids ” - Symposium on Microgrids, Jeju Island, Korea, May 2011...Military Smart Grids & Microgrids Conference – May 2012 • DOE Microgrid Workshop – July 2012 GE has also started using news media and blogs to...Microgrid Technologies – 29 Palms – Distribution Optimization in Smart Grids ” - Symposium on Microgrids, Jeju Island, Korea, May 2011 o Military

  12. Micro-Grids for Colonias (TX)

    Energy Technology Data Exchange (ETDEWEB)

    Dean Schneider; Michael Martin; Renee Berry; Charles Moyer

    2012-07-31

    This report describes the results of the final implementation and testing of a hybrid micro-grid system designed for off-grid applications in underserved Colonias along the Texas/Mexico border. The project is a federally funded follow-on to a project funded by the Texas State Energy Conservation Office in 2007 that developed and demonstrated initial prototype hybrid generation systems consisting of a proprietary energy storage technology, high efficiency charging and inverting systems, photovoltaic cells, a wind turbine, and bio-diesel generators. This combination of technologies provided continuous power to dwellings that are not grid connected, with a significant savings in fuel by allowing power generation at highly efficient operating conditions. The objective of this project was to complete development of the prototype systems and to finalize and engineering design; to install and operate the systems in the intended environment, and to evaluate the technical and economic effectiveness of the systems. The objectives of this project were met. This report documents the final design that was achieved and includes the engineering design documents for the system. The system operated as designed, with the system availability limited by maintenance requirements of the diesel gensets. Overall, the system achieved a 96% availability over the operation of the three deployed systems. Capital costs of the systems were dependent upon both the size of the generation system and the scope of the distribution grid, but, in this instance, the systems averaged $0.72/kWh delivered. This cost would decrease significantly as utilization of the system increased. The system with the highest utilization achieved a capitol cost amortized value of $0.34/kWh produced. The average amortized fuel and maintenance cost was $0.48/kWh which was dependent upon the amount of maintenance required by the diesel generator. Economically, the system is difficult to justify as an alternative to grid

  13. Development of a hardware-based AC microgrid for AC stability assessment

    Science.gov (United States)

    Swanson, Robert R.

    As more power electronic-based devices enable the development of high-bandwidth AC microgrids, the topic of microgrid power distribution stability has become of increased interest. Recently, researchers have proposed a relatively straightforward method to assess the stability of AC systems based upon the time-constants of sources, the net bus capacitance, and the rate limits of sources. In this research, a focus has been to develop a hardware test system to evaluate AC system stability. As a first step, a time domain model of a two converter microgrid was established in which a three phase inverter acts as a power source and an active rectifier serves as an adjustable constant power AC load. The constant power load can be utilized to create rapid power flow transients to the generating system. As a second step, the inverter and active rectifier were designed using a Smart Power Module IGBT for switching and an embedded microcontroller as a processor for algorithm implementation. The inverter and active rectifier were designed to operate simultaneously using a synchronization signal to ensure each respective local controller operates in a common reference frame. Finally, the physical system was created and initial testing performed to validate the hardware functionality as a variable amplitude and variable frequency AC system.

  14. 75 FR 39954 - Oversight of Laboratory Developed Tests; Public Meeting; Change of Meeting Location

    Science.gov (United States)

    2010-07-13

    ... HUMAN SERVICES Food and Drug Administration Oversight of Laboratory Developed Tests; Public Meeting... entitled ``Oversight of Laboratory Developed Tests.'' A new address is given for those attending the public... interested stakeholders to discuss the agency's oversight of laboratory developed tests. FDA announced in...

  15. Transportable Heavy Duty Emissions Testing Laboratory and Research Program

    Energy Technology Data Exchange (ETDEWEB)

    David Lyons

    2008-03-31

    The objective of this program was to quantify the emissions from heavy-duty vehicles operating on alternative fuels or advanced fuel blends, often with novel engine technology or aftertreatment. In the first year of the program West Virginia University (WVU) researchers determined that a transportable chassis dynamometer emissions measurement approach was required so that fleets of trucks and buses did not need to be ferried across the nation to a fixed facility. A Transportable Heavy-Duty Vehicle Emissions Testing Laboratory (Translab) was designed, constructed and verified. This laboratory consisted of a chassis dynamometer semi-trailer and an analytic trailer housing a full scale exhaust dilution tunnel and sampling system which mimicked closely the system described in the Code of Federal Regulations for engine certification. The Translab was first used to quantify emissions from natural gas and methanol fueled transit buses, and a second Translab unit was constructed to satisfy research demand. Subsequent emissions measurement was performed on trucks and buses using ethanol, Fischer-Tropsch fuel, and biodiesel. A medium-duty chassis dynamometer was also designed and constructed to facilitate research on delivery vehicles in the 10,000 to 20,000lb range. The Translab participated in major programs to evaluate low-sulfur diesel in conjunction with passively regenerating exhaust particulate filtration technology, and substantial reductions in particulate matter were recorded. The researchers also participated in programs to evaluate emissions from advanced natural gas engines with closed loop feedback control. These natural gas engines showed substantially reduced levels of oxides of nitrogen. For all of the trucks and buses characterized, the levels of carbon monoxide, oxides of nitrogen, hydrocarbons, carbon dioxide and particulate matter were quantified, and in many cases non-regulated species such as aldehydes were also sampled. Particle size was also

  16. Interconnecting Microgrids via the Energy Router with Smart Energy Management

    Directory of Open Access Journals (Sweden)

    Yingshu Liu

    2017-08-01

    Full Text Available A novel and flexible interconnecting framework for microgrids and corresponding energy management strategies are presented, in response to the situation of increasing renewable-energy penetration and the need to alleviate dependency on energy storage equipment. The key idea is to establish complementary energy exchange between adjacent microgrids through a multiport electrical energy router, according to the consideration that adjacent microgrids may differ substantially in terms of their patterns of energy production and consumption, which can be utilized to compensate for each other’s instant energy deficit. Based on multiport bidirectional voltage source converters (VSCs and a shared direct current (DC power line, the energy router serves as an energy hub, and enables flexible energy flow among the adjacent microgrids and the main grid. The analytical model is established for the whole system, including the energy router, the interconnected microgrids and the main grid. Various operational modes of the interconnected microgrids, facilitated by the energy router, are analyzed, and the corresponding control strategies are developed. Simulations are carried out on the Matlab/Simulink platform, and the results have demonstrated the validity and reliability of the idea for microgrid interconnection as well as the corresponding control strategies for flexible energy flow.

  17. Customized electric power storage device for inclusion in a collective microgrid

    Science.gov (United States)

    Robinett, III, Rush D.; Wilson, David G.; Goldsmith, Steven Y.

    2016-02-16

    An electric power storage device is described herein, wherein the electric power storage device is included in a microgrid. The electric power storage device has at least one of a charge rate, a discharge rate, or a power retention capacity that has been customized for a collective microgrid. The collective microgrid includes at least two connected microgrids. The at least one of the charge rate, the discharge rate, or the power retention capacity of the electric power storage device is computed based at least in part upon specified power source parameters in the at least two connected microgrids and specified load parameters in the at least two connected microgrids.

  18. Photovoltaic Electricity for Sustainable Building. Efficiency and Energy Cost Reduction for Isolated DC Microgrid

    Directory of Open Access Journals (Sweden)

    Manuela Sechilariu

    2015-07-01

    Full Text Available In the context of sustainable buildings, this paper investigates power flow management for an isolated DC microgrid and focuses on efficiency and energy cost reduction by optimal scheduling. Aiming at high efficiency, the local produced power has to be used where, when, and how it is generated. Thus, based on photovoltaic sources, storage, and a biofuel generator, the proposed DC microgrid is coupled with the DC distribution network of the building. The DC bus distribution maximizes the efficiency of the overall production-consumption system by avoiding some energy conversion losses and absence of reactive power. The isolated DC microgrid aims to minimize the total energy cost and thus, based on forecasting data, a cost function is formulated. Using a mixed integer linear programming optimization, the optimal power flow scheduling is obtained which leads to an optimization-based strategy for real-time power balancing. Three experimental tests, operated under different meteorological conditions, validate the feasibility of the proposed control and demonstrate the problem formulation of minimizing total energy cost.

  19. Designing an Energy Storage System Fuzzy PID Controller for Microgrid Islanded Operation

    Directory of Open Access Journals (Sweden)

    Jin-Hong Jeon

    2011-09-01

    Full Text Available Recently, interest in microgrids, which are composed of distributed generation (DG, distributed storage (DS, and loads, has been growing as a potentially effective clean energy system to mitigate against climate change. The microgrid is operated in the grid-connected mode and the islanded mode according to the conditions of the upstream power grid. The role of the energy storage system (ESS is especially important to maintain constant the frequency and voltage of an islanded microgrid. For this reason, various approaches for ESS control have been put forth. In this paper, a fuzzy PID controller is proposed to improve the frequency control performance of the ESS. This fuzzy PID controller consists of a fuzzy logic controller and a conventional PI controller, connected in series. The fuzzy logic controller has two input signals, and then the output signal of the fuzzy logic controller is the input signal of the conventional PI controller. For comparison of control performance, gains of each PI controller and fuzzy PID controller are tuned by the particle swam optimization (PSO algorithm. In the simulation study, the control performance of the fuzzy PID was also tested under various operating conditions using the PSCAD/EMTDC simulation platform.

  20. Hardware-in-the-Loop Simulation of Distributed Intelligent Energy Management System for Microgrids

    Directory of Open Access Journals (Sweden)

    Dong-Jun Won

    2013-07-01

    Full Text Available Microgrids are autonomous low-voltage power distribution systems that contain multiple distributed energy resources (DERs and smart loads that can provide power system operation flexibility. To effectively control and coordinate multiple DERs and loads of microgrids, this paper proposes a distributed intelligent management system that employs a multi-agent-based control system so that delicate decision-making functions can be distributed to local intelligent agents. This paper presents the development of a hardware-in-the-loop simulation (HILS system for distributed intelligent management system for microgrids and its promising application to an emergency demand response program. In the developed HILS system, intelligent agents are developed using microcontrollers and ZigBee wireless communication technology. Power system dynamic models are implemented in real-time simulation environments using the Opal-RT system. This paper presents key features of the data communication and management schemes based on multi-agent concepts. The performance of the developed system is tested for emergency demand response program applications.

  1. Internship at NASA Kennedy Space Center's Cryogenic Test laboratory

    Science.gov (United States)

    Holland, Katherine

    2013-01-01

    NASA's Kennedy Space Center (KSC) is known for hosting all of the United States manned rocket launches as well as many unmanned launches at low inclinations. Even though the Space Shuttle recently retired, they are continuing to support unmanned launches and modifying manned launch facilities. Before a rocket can be launched, it has to go through months of preparation, called processing. Pieces of a rocket and its payload may come in from anywhere in the nation or even the world. The facilities all around the center help integrate the rocket and prepare it for launch. As NASA prepares for the Space Launch System, a rocket designed to take astronauts beyond Low Earth Orbit throughout the solar system, technology development is crucial for enhancing launch capabilities at the KSC. The Cryogenics Test Laboratory at Kennedy Space Center greatly contributes to cryogenic research and technology development. The engineers and technicians that work there come up with new ways to efficiently store and transfer liquid cryogens. NASA has a great need for this research and technology development as it deals with cryogenic liquid hydrogen and liquid oxygen for rocket fuel, as well as long term space flight applications. Additionally, in this new era of space exploration, the Cryogenics Test Laboratory works with the commercial sector. One technology development project is the Liquid Hydrogen (LH2) Ground Operations Demonstration Unit (GODU). LH2 GODU intends to demonstrate increased efficiency in storing and transferring liquid hydrogen during processing, loading, launch and spaceflight of a spacecraft. During the Shuttle Program, only 55% of hydrogen purchased was used by the Space Shuttle Main Engines. GODU's goal is to demonstrate that this percentage can be increased to 75%. Figure 2 shows the GODU layout when I concluded my internship. The site will include a 33,000 gallon hydrogen tank (shown in cyan) with a heat exchanger inside the hydrogen tank attached to a

  2. Laboratory testing of a lethal ovitrap for Aedes aegypti.

    Science.gov (United States)

    Zeichner, B C; Perich, M J

    1999-07-01

    Laboratory tests were conducted to determine the feasibility of making the mosquito ovitrap lethal to Aedes aegypti (L.) when they attempt to oviposit in the trap. Heavy-weight velour paper strips (2.54 x 11 cm) were used as an alternative to the wooden paddle normally provided as a substrate for mosquito oviposition. The paper strips were pretreated with insecticide solutions and allowed to dry before being used in oviposition cups of 473 ml capacity, filled with water initially to within 2.5 cm of the brim. Insecticides chosen for their quick knock-down efficacy were bendiocarb 76% WP (1.06 mg a.i./strip) and four pyrethroids: permethrin 25% WP (0.16 mg a.i./strip), deltamethin 4.75% SC (0.87 mg a.i./strip), cypermethrin 40% WP (2.81 mg a.i./strip), and cyfluthrin 20% WP (0.57 mg a.i./ strip). For experimental evaluation, two oviposition cups (one with an insecticide-treated strip and one with an untreated strip) were placed in cages (cubic 30 cm) with gravid female Ae. aegypti mosquitoes (aged 6-8 days) from a susceptible laboratory strain. Mortality-rates of female mosquitoes were 45% for bendiocarb, 47% for permethrin, 98% for deltamethrin, 100% for cypermethrin, and 100% for cyfluthrin. Young instar larvae added to the treated cups died within 2h. After water evaporation from the cups for 38 days, fresh mosquito females had access to previously submerged portions of the velour paper paddle, and mortality rates of 59% or more occurred. Cups that had water (360 ml) dripped into them, to simulate rain, produced female mosquito mortality rates of > 50% and all larvae died within 3 h of being added. These tests demonstrate that the ovitrap can be made lethal to both adults and larvae by insecticidal treatment of the ovistrip. Field efficacy trials are underway in Brazil to access the impact of this simple, low-cost, environmentally benign approach on populations of the dengue vector Ae. aegypti.

  3. 9 CFR 54.11 - Approval of laboratories to run official scrapie tests and official genotype tests.

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Approval of laboratories to run official scrapie tests and official genotype tests. 54.11 Section 54.11 Animals and Animal Products ANIMAL... laboratories to run official scrapie tests and official genotype tests. (a) State, Federal, and...

  4. Fault Analysis and Detection in Microgrids with High PV Penetration

    Energy Technology Data Exchange (ETDEWEB)

    El Khatib, Mohamed [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Hernandez Alvidrez, Javier [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Ellis, Abraham [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-05-01

    In this report we focus on analyzing current-controlled PV inverters behaviour under faults in order to develop fault detection schemes for microgrids with high PV penetration. Inverter model suitable for steady state fault studies is presented and the impact of PV inverters on two protection elements is analyzed. The studied protection elements are superimposed quantities based directional element and negative sequence directional element. Additionally, several non-overcurrent fault detection schemes are discussed in this report for microgrids with high PV penetration. A detailed time-domain simulation study is presented to assess the performance of the presented fault detection schemes under different microgrid modes of operation.

  5. Capability of the Gas Analysis and Testing Laboratory at the NASA Johnson Space Center

    Science.gov (United States)

    Broerman, Craig; Jimenez, Javier; Sweterlitsch, Jeff

    2012-01-01

    The Gas Analysis and Testing Laboratory is an integral part of the testing performed at the NASA Johnson Space Center. The Gas Analysis and Testing Laboratory is a high performance laboratory providing real time analytical instruments to support manned and unmanned testing. The lab utilizes precision gas chromatographs, gas analyzers and spectrophotometers to support the technology development programs within the NASA community. The Gas Analysis and Testing Laboratory works with a wide variety of customers and provides engineering support for user-specified applications in compressed gas, chemical analysis, general and research laboratory.

  6. Mycobacterium tuberculosis testing practices in hospital, commercial and state laboratories in the New England states.

    Science.gov (United States)

    Livingston, K A; Lobato, M N; Sosa, L E; Budnick, G E; Bernardo, J

    2011-09-01

    The mycobacterial laboratory is assuming an increasingly important role in tuberculosis (TB) control in the United States today. To assess mycobacterial laboratory capacity and practices in the New England states, USA. We surveyed 143 hospital and commercial laboratories and five of the six state public health laboratories in New England that offer testing services for Mycobacterium tuberculosis. The survey captured information on types of services offered and volume of testing, use of state laboratories for testing, and promptness of reporting results to TB control programs. State laboratories perform the majority of testing services, particularly for more specialized tests. All state laboratories surveyed perform species identification of acid-fast isolates, culture and first-line drug susceptibility testing. Less than 20% of hospital and commercial laboratories offer these services, and 78.6% of hospitals and commercial laboratories refer specimens to state laboratories for culture. Surveys of M. tuberculosis testing capacities in a region can help decision makers ensure maintenance of essential services. Hospital and commercial laboratories with lower testing volume might increase efficiency by referring more specimens to state laboratories. State health departments might consider organizing regional laboratory service networks to monitor the provision of services, improve efficiency and oversee quality improvement initiatives.

  7. 78 FR 46996 - Current List of Laboratories and Instrumented Initial Testing Facilities Which Meet Minimum...

    Science.gov (United States)

    2013-08-02

    ... 503 of Public Law 100-71. The ``Mandatory Guidelines for Federal Workplace Drug Testing Programs'', as... Laboratory Partnership, 245 Pall Mall Street, London, ONT, Canada N6A 1P4, 519-679-1630 Laboratory...: Centinela Hospital Airport Toxicology Laboratory) Pathology Associates Medical Laboratories, 110 West Cliff...

  8. 78 FR 39757 - Current List of Laboratories and Instrumented Initial Testing Facilities Which Meet Minimum...

    Science.gov (United States)

    2013-07-02

    ... 503 of Public Law 100-71. The ``Mandatory Guidelines for Federal Workplace Drug Testing Programs'', as... Laboratory Partnership, 245 Pall Mall Street, London, ONT, Canada N6A 1P4, 519-679-1630 Laboratory...: Centinela Hospital Airport Toxicology Laboratory) Pathology Associates Medical Laboratories, 110 West Cliff...

  9. Reliability quantification and visualization for electric microgrids

    Science.gov (United States)

    Panwar, Mayank

    The electric grid in the United States is undergoing modernization from the state of an aging infrastructure of the past to a more robust and reliable power system of the future. The primary efforts in this direction have come from the federal government through the American Recovery and Reinvestment Act of 2009 (Recovery Act). This has provided the U.S. Department of Energy (DOE) with 4.5 billion to develop and implement programs through DOE's Office of Electricity Delivery and Energy Reliability (OE) over the a period of 5 years (2008-2012). This was initially a part of Title XIII of the Energy Independence and Security Act of 2007 (EISA) which was later modified by Recovery Act. As a part of DOE's Smart Grid Programs, Smart Grid Investment Grants (SGIG), and Smart Grid Demonstration Projects (SGDP) were developed as two of the largest programs with federal grants of 3.4 billion and $600 million respectively. The Renewable and Distributed Systems Integration (RDSI) demonstration projects were launched in 2008 with the aim of reducing peak electricity demand by 15 percent at distribution feeders. Nine such projects were competitively selected located around the nation. The City of Fort Collins in co-operative partnership with other federal and commercial entities was identified to research, develop and demonstrate a 3.5MW integrated mix of heterogeneous distributed energy resources (DER) to reduce peak load on two feeders by 20-30 percent. This project was called FortZED RDSI and provided an opportunity to demonstrate integrated operation of group of assets including demand response (DR), as a single controllable entity which is often called a microgrid. As per IEEE Standard 1547.4-2011 (IEEE Guide for Design, Operation, and Integration of Distributed Resource Island Systems with Electric Power Systems), a microgrid can be defined as an electric power system which has following characteristics: (1) DR and load are present, (2) has the ability to disconnect from

  10. Biosolid Soil Application: Toxicity Tests under Laboratory Conditions

    Directory of Open Access Journals (Sweden)

    Cintya Ap. Christofoletti

    2012-01-01

    Full Text Available A large volume of generated sewage sludge makes its disposal a problem. The usage of sludge in agriculture is highlighted by a number of advantages. However, heavy metals and other toxic compounds may exercise harmful effects to soil organisms. This study evaluated the possible toxic effects of a biosolid sample, under laboratory conditions, for 30 days, using diplopods Rhinocricus padbergi and plants Allium cepa (onion as test organisms. The data obtained demonstrated that the biosolid raw sample had genotoxic potential for Allium cepa root tip cells. In the diplopods exposed to biosolid sample, epithelium disorganization in the midgut and a reduction of the volume of the hepatic cells were observed after 7 days of exposure. After 30 days, the animals still showed a reduction of the volume of the hepatic cells, but in minor intensity. Allium cepa analysis showed genotoxicity, but this effect was reduced after 30 days of bioprocessing by diplopods. This study was important to know the effects as well as to determine how this waste could be applied concerning the soil living organisms and plants.

  11. Reliability Analysis of a Novel Distribution Network with Microgrid%含微电网的新型配电网供电可靠性分析

    Institute of Scientific and Technical Information of China (English)

    解翔; 袁越; 李振杰

    2011-01-01

    新型配电网结构--微电网是智能电网的有机组成部分,它能有效提高用户的安全性和可靠性.根据新兴微电网的特点,总结出含微电网的配电网可靠性算法.通过分析微电网加入配电网后可靠性指标的改善,评佑微电网对配电网可靠性的影响.以实际系统为例,应用所述算法,从可靠性参数角度,给微电网安装的位置和容量提出建议.%A novel distribution network structure, the microgrid, is an integral part of the smart grid capable of effectively improving user security and reliability. According to the characteristics of the burgeoning smart microgrid, a reliability algorithm for distribution network with smart microgrid is concluded. The impact of microgrid on the reliability of distribution network is assessed by analyzing the improvement of reliability parameters. With this algorithm, the reliability of the test system is achieved, with which, some recommendations about location and capacity of the microgrid are made.

  12. Increasing Resiliency Through Renewable Energy Microgrids

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, Katherine H [National Renewable Energy Laboratory (NREL), Golden, CO (United States); DiOrio, Nicholas A [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Cutler, Dylan S [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Butt, Robert S [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Richards, Allison [unaffiliated

    2017-08-01

    This paper describes a methodology to quantify the economic and resiliency benefit provided by renewable energy (RE) in a hybrid RE-storage-diesel microgrid. We present a case study to show how this methodology is applied to a multi-use/ multi-function telecommunications facility in southern California. In the case study, we first identify photovoltaic (PV) and battery energy storage system (BESS) technologies that minimize the lifecycle cost of energy at the site under normal, grid-connected operation. We then evaluate how those technologies could be incorporated alongside existing diesel generators in a microgrid to increase resiliency at the site, where resiliency is quantified in terms of the amount of time that the microgrid can sustain the critical load during a grid outage. We find that adding PV and BESS to the existing backup diesel generators with a fixed fuel supply extends the amount of time the site could survive an outage by 1.8 days, from 1.7 days for the existing diesel-only backup system to 3.5 days for the PV/diesel/BESS hybrid system. Furthermore, even after diesel fuel supplies are exhausted, the site can continue to operate critical loads during daytime hours using just the PV/BESS when there is sufficient solar resource. We find that the site can save approximately $100,000 in energy costs over the 25-year lifecycle while doubling the amount of time they can survive an outage. The methodology presented here provides a template for increasing resiliency at telecomm sites by implementing renewable energy solutions, which provide additional benefits of carbon emission reduction and energy cost savings.

  13. Hierarchical Control for Multiple DC Microgrids Clusters

    DEFF Research Database (Denmark)

    Shafiee, Qobad; Dragicevic, Tomislav; Vasquez, Juan Carlos;

    2014-01-01

    This paper presents a distributed hierarchical control framework to ensure reliable operation of dc Microgrid (MG) clusters. In this hierarchy, primary control is used to regulate the common bus voltage inside each MG locally. An adaptive droop method is proposed for this level which determines....... Another distributed policy is employed then to regulate the power flow among the MGs according to their local SOCs. The proposed distributed controllers on each MG communicate with only the neighbor MGs through a communication infrastructure. Finally, the small signal model is expanded for dc MG clusters...

  14. Decentralized Coordinated Control Strategy of Islanded Microgrids

    DEFF Research Database (Denmark)

    Wu, Dan

    as grid voltage/frequency regulation. In order to enhance the reliability of overall islanded Microgrid operation, basic functions of coordinated control which taking into account the state of charge (SoC) limitation and power availability of renewable energy sources is implemented in a distributed level...... control strategies in this thesis, in order to promote the decentralization of the overall system. Especially the consensus algorithm based secondary level is investigated in the thesis in order to simplify the communication configuration which only flood information through the neighboring units...

  15. DC Hierarchical Control System for Microgrid Applications

    OpenAIRE

    Lu, Xiaonan; Sun, Kai; Guerrero, Josep M.; Huang, Lipei

    2013-01-01

    In order to enhance the DC side performance of AC-DC hybrid microgrid,a DC hierarchical control system is proposed in this paper.To meet the requirement of DC load sharing between the parallel power interfaces,droop method is adopted.Meanwhile,DC voltage secondary control is employed to restore the deviation in the DC bus voltage.The hierarchical control system is composed of two levels.DC voltage and AC current controllers are achieved in the primary control level.

  16. Capacity credit of microgeneration and microgrids

    Energy Technology Data Exchange (ETDEWEB)

    Moises Costa, Paulo [Escola Superior Tecnologia e Gestao de Viseu, Instituto Politecnico Viseu, Viseu (Portugal); INESC Porto (Portugal); Matos, Manuel A. [INESC Porto, Faculdade de Engenharia, Universidade do Porto, Porto (Portugal)

    2010-10-15

    The recent development of the concept of microgrid ({mu}Grid), associated to the emergent interest in microgeneration ({mu}Gen), has raised a number of challenges regarding the evaluation of the technical, economical and regulatory impacts of a high penetration of this kind of solutions in the power systems. In this paper, the topic of security of supply is addressed, aiming at evaluating the influence of {mu}Gen and {mu}Grids in the medium- and long-term availability of generation to serve the forecasted load. A Monte-Carlo based methodology is used to evaluate this influence and to assess the capacity credit of those entities. (author)

  17. Line-Interactive UPS for Microgrids

    DEFF Research Database (Denmark)

    Abusara, Mohammad; Guerrero, Josep M.; Sharkh, Suleiman

    2014-01-01

    Line interactive Uninterruptable Power Supply (UPS) systems are good candidates for providing energy storage within a microgrid to help improve its reliability, economy and efficiency. In grid-connected mode, power can be imported from the grid by the UPS to charge its battery. Power can also...... be exported when required, e.g., when the tariffs are advantageous. In stand-alone mode, the UPS supplies local distributed loads in parallel with other sources. In this paper, a line interactive UPS and its control system are presented and discussed. Power flow is controlled using the frequency and voltage...

  18. Multi-laboratory precision of Marshall design related tests

    CSIR Research Space (South Africa)

    Denneman, E

    2008-07-01

    Full Text Available by different laboratories. The variability was of such a degree that it would influence design decisions or could lead to conflict over product acceptance. A study was undertaken to investigate the extent and consequences of the inter-laboratory variability...

  19. Information comparison of the effects of drugs on laboratory tests in drug labels and Young's book

    NARCIS (Netherlands)

    Geerts, A.F.; Koning, F.H. de; Egberts, T.C.; Smet, P.A. de; Solinge, W.W. van

    2012-01-01

    Abstract Background: The effects of drugs on laboratory tests may lead to misinterpretation of laboratory data, unnecessary tests, higher costs and missed diagnoses. This study compared the information on drug-laboratory effects (DLE) described in 200 drug labels with that in Young's book. Methods:

  20. 7 CFR 91.37 - Standard hourly fee rate for laboratory testing, analysis, and other services.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Standard hourly fee rate for laboratory testing... Charges § 91.37 Standard hourly fee rate for laboratory testing, analysis, and other services. (a) The standard hourly fee rate in this section for the individual laboratory analyses cover the costs of...

  1. Standards for thyroid laboratory testing, and cognitive functions after menopause

    Directory of Open Access Journals (Sweden)

    Iwona Bojar

    2014-09-01

    Full Text Available Introduction : The aim of the study is to analyze the relationship between normative and non-normative thyroid tests (TSH, TT4, TT3, FT3, FT4, anti-TPO, anti-Tg, AB-TSHR and the level of cognitive functions in postmenopausal women. Material and methods: The study group consisted of 383 women from south-eastern Poland, aged 50-65 years. The cognitive functions were evaluated using a diagnostic instrument – Central Nervous System – Vital Signs (CNS-VS. Blood was collected for determination of the following parameters: TSH, TT4, TT3, FT3, FT4, anti-TPO, anti-Tg, AB-TSHR. Results: There were significant differences in NCI, executive functions, psychomotor speed, reaction time, complex attention and cognitive flexibility, depending on the normative and non-normative level of TSH. Women whose level of FT3 was at the lower limit of the normal range obtained poorer results in psychomotor speed, while subjects with levels of FT4 below the standard achieved significantly lower scores for this function. The relationship between NCI and cognitive functions, and the normative and non-normative anti-TPO results, showed significant differences in verbal memory, visual memory, processing speed and reaction time. The level of AB-TSHR reported as normal or above the norm significantly differentiated from the results of NCI, processing speed, executive functions, psychomotor speed, complex attention and cognitive flexibility. Conclusions : Concentrations of laboratory parameters assessing the thyroid function located within the upper limits of the normal range showed a different relationship with the cognitive performance than concentrations located within the lower limits of the standard.

  2. Distributed Generation Investment by a Microgrid under Uncertainty

    Energy Technology Data Exchange (ETDEWEB)

    Marnay, Chris; Siddiqui, Afzal; Marnay, Chris

    2008-08-11

    This paper examines a California-based microgrid?s decision to invest in a distributed generation (DG) unit fuelled by natural gas. While the long-term natural gas generation cost is stochastic, we initially assume that the microgrid may purchase electricity at a fixed retail rate from its utility. Using the real options approach, we find a natural gas generation cost threshold that triggers DG investment. Furthermore, the consideration of operational flexibility by the microgrid increases DG investment, while the option to disconnect from the utility is not attractive. By allowing the electricity price to be stochastic, we next determine an investment threshold boundary and find that high electricity price volatility relative to that of natural gas generation cost delays investment while simultaneously increasing the value of the investment. We conclude by using this result to find the implicit option value of the DG unit when two sources of uncertainty exist.

  3. Microgrids in Active Network Management-Part I

    DEFF Research Database (Denmark)

    Palizban, Omid; Kauhaniemia, Kimmo; Guerrero, Josep M.

    2014-01-01

    The microgrid concept has been closely investigated and implemented by numerous experts worldwide. The first part of this paper describes the principles of microgrid design, considering the operational concepts and requirements arising from participation in active network management. Over the las......, energy storage systems, and market participation in both island and grid-connection operation. Finally, control techniques and the principles of energy-storage systems are summarized in a comprehensive flowchart.......The microgrid concept has been closely investigated and implemented by numerous experts worldwide. The first part of this paper describes the principles of microgrid design, considering the operational concepts and requirements arising from participation in active network management. Over the last...

  4. Microgrids in Active Network Management-Part II

    DEFF Research Database (Denmark)

    Palizban, Omid; Kauhaniemi, Kimmo; Guerrero, Josep M.

    2014-01-01

    , following planned or unplanned transitions to island mode, microgrids may develop instability. For this reason, the paper addresses the principles behind island-detection methods, black-start operation, fault management, and protection systems, along with a comprehensive review of power quality. Finally......The development of distribution networks for participation in active network management (ANM) and smart grids is introduced using the microgrid concept. In recent years, this issue has been researched and implemented by many experts. The second part of this paper describes those developed...... operational concepts of microgrids that have an impact on their participation in ANM and in the requirements for achieving targets. Power quality is the most challenging task in microgrids, especially when the system switches from normal parallel operation (grid-connection mode) to island operation. Indeed...

  5. Distributed energy resources in grid interactive AC microgrids

    DEFF Research Database (Denmark)

    Wang, Xiongfei; Guerrero, Josep; Chen, Zhe

    2010-01-01

    Increased penetration of distributed energy resources (DER) and large-scale deployment of renewable energy sources are challenging the entire architecture of traditional power system. Microgrid, featuring higher flexibility and reliability, becomes an attractive candidate for the configuration of...

  6. A knowledge discovery in databases approach for industrial microgrid planning

    DEFF Research Database (Denmark)

    Gamarra, Carlos; Guerrero, Josep M.; Montero, Eduardo

    2016-01-01

    sustainable and proactive microgrid which allows identifying, designing and developing energy efficiency strategies at supply, management and energy use levels. In this context, the expansion of Internet of Things and Knowledge Discovery in Databases techniques will drive changes in current microgrid planning...... to minimize the environmental impact of manufacturing processes. At the same time, microgrid architectures are progressively being developed, proving to be suitable for supplying energy to continuous and intensive consumptions, such as manufacturing processes. In the merge of these two tendencies, industrial...... microgrid development could be considered a step forward towards more sustainable manufacturing processes if planning engineers are capable to design a power supply system, not only focused on historical demand data, but also on manufacturing and environmental data. The challenge is to develop a more...

  7. Microgrid Policy Review of Selected Major Countries, Regions, and Organizations

    Energy Technology Data Exchange (ETDEWEB)

    Qu, Min [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Marnay, Chris [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Zhou, Nan [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2011-11-30

    This report collects and reviews policies and regulations related to microgrid development, and is intended as a reference. The material is divided into three parts under five dimensions: interconnection, RD&D, tariff policy, other policies, and recommendations.

  8. Differential Protection for Distributed Micro-Grid Based on Agent

    Directory of Open Access Journals (Sweden)

    ZHOU Bin

    2013-05-01

    Full Text Available The Micro-grid, even though not a replacement of the conventional centralized power transmission grid, plays a very important role in the success of rapid development of renewable energy resources technologies. Due to the facts of decentralization, independence and dynamic of sources within a Micro-grid, a high level automation of protection is a must. Multi-Agent system as a approach to handle distributed system issues has been developed. This paper presents an MAS based differential protection method for distributed micro-grid. The nodes within a micro-grid are divided into primary and backup protection zones. The agents follow predefined rules to take actions to protect the system and isolate the fault when it happens. Furthermore, an algorithm is proposed to achieve high availability in case of Agent itself malfunction. The method is using Matlab for simulation and shows it satisfies relay protection in terms of the selectivity, sensitivity, rapidity and reliability requirements.

  9. The Phillips Laboratory capillary pumped loop test facility

    Science.gov (United States)

    Gluck, Donald F.; Kaylor, Marc C.

    1996-03-01

    An ammonia capillary pumped loop (CPL) test facility has been designed, fabricated, subject to acceptance tests, and assembled at Phillips Laboratory. Its intent is to support a wide range of Air Force programs, bringing CPL technology to flight readiness for operational systems. The facility provides a high degree of modularity and flexibility with several heating and cooling options, and capability for elevation (+/- 15 in.), tilt (+/-60°) and transport length variation. It has a 182 by 44 by 84 inch envelope, an expected heat load capability of 2500 W, and a temperature range of 0 to 50 °C. The evaporator section has two plates with four capillary pumps (CPs) each, with a starter pump on one plate. The CPs are 5/8 in., with TAG aluminum 6063-T6 casing and UHMW polyethylene wicks. The active lengths are 15 and 30 inch with both 10 and 15 micron wicks. The individual CPs have thermal and hydraulic isolation capability, and are removable. The transport section consists of stainless steel lines in a serpentine configuration, a 216 in3 free volume reservoir, and a mechanical pump. The vapor transport line contains a capillary device (which can be bypassed) for vapor blockage during startup. The condenser consists of two separately valved, parallel cold plates each with a downstream noncondensible gas trap. Cooling of up to 1500 W at -50 °C is provided by an FTS Systems chiller using Flourinert FC-72. An enclosure/exhaust system is provided for safety and emergency venting of ammonia. An ammonia charge station performs or supports the functions of proof pressure, flushing with ammonia, purging with gaseous nitrogen, evacuation of all or part of the CPL to 20 microns, and charging. Instrumentation consists of over 116 thermocouples, five of which are internal; one absolute and six differential pressure transducers; eleven watt transducers, and a reservoir load cell. The data acquisition system consists of a temperature scanner, Bernoulli drive, and two Macintosh

  10. Settling velocity of marine microplastic particles: laboratory tests

    Science.gov (United States)

    Isachenko, Igor; Khatmullina, Lilia; Chubarenko, Irina; Stepanova, Natalia

    2016-04-01

    An assessment of the settling velocity of different classes of microplastic particles (microplastic particles is usually outside the Stokes range (Re 105). Even for such transitional regime, the settling velocity of the particles that could be treated as more or less smooth spheres can be predicted with high accuracy by relationships available in publications. This is not the case for the non-spherical particles like fibres or flakes. There are quite a large number of quasi-theoretical or semi-empirical approaches that take into account the shape and roughness of the particles, usually in the applications to transport of natural sediments. Some engineering formulas for the settling velocity are also developed which have simpler structure along with high degree of accuracy on the set of experimental data. For marine microplastic particles, the absence of relationship between the settling velocity and the properties of the particle requires testing on the samples of marine microplastics. Besides small fragments of rigid plastic (granules, microbeads), there are also fibres and thin plastic sheets (flakes) with some degree of flexibility. The applicability of available formulae to thin and/or flexible plastic particles again requires verification by experiments. The set of laboratory experiments on settling of microplastic particles of various shapes and excess densities in homogeneous water is reported. The particles were collected in water column, bottom sediments and on the beaches of the South-Eastern Baltic. The experiments demonstrate not just different regimes of motion but different manner of the sinking of spheres, flakes and fibres. The very definition of the "settling velocity" has a specific meaning for every kind of a particle shape. The results of test measurements are compared with predictions by several published semi-empirical formulae. We conclude that there are several new questions to discuss in this regard: (i) proper definition of the meaning of

  11. The National Market for Medicare Clinical Laboratory Testing

    Data.gov (United States)

    U.S. Department of Health & Human Services — Current Medicare payment policy for outpatient laboratory services is outdated. Future reforms, such as competitive bidding, should consider the characteristics of...

  12. Preference Testing as Environmental Enrichment Assessment for Laboratory Mice

    National Research Council Canada - National Science Library

    Navakanit Sachanonta; Waridtha Sa-ngeunreung; Somchai Sa-ing-kaew; Raywadee Butraporn

    2013-01-01

      In the field of biomedical research, a wide variety of environmental enrichment items are available for laboratory mice to fulfill its physiological and behavioral needs which influence the outcome...

  13. The National Market for Medicare Clinical Laboratory Testing

    Data.gov (United States)

    U.S. Department of Health & Human Services — Current Medicare payment policy for outpatient laboratory services is outdated. Future reforms, such as competitive bidding, should consider the characteristics of...

  14. Elusive antimatter formed in laboratory scientists testing nature's deepest secrets

    CERN Multimedia

    Boyd, R S

    2002-01-01

    A team of European physicists reported the creation in a Swiss laboratory of at least 50,000 atoms of antihydrogen, the first time a significant quantity of antimatter has been produced on earth (1 page).

  15. Results of Laboratory Testing of Advanced Power Strips: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Earle, L.; Sparn, B.

    2012-08-01

    This paper describes the results of a laboratory investigation to evaluate the technical performance of advanced power strip (APS) devices when subjected to a range of home entertainment center and home office usage scenarios.

  16. Protection of Renewable-dominated Microgrids: Challenges and Potential Solutions

    Energy Technology Data Exchange (ETDEWEB)

    Elkhatib, Mohamed [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Ellis, Abraham [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Biswal, Milan [New Mexico State Univ., Las Cruces, NM (United States); Brahma, Sukumar [New Mexico State Univ., Las Cruces, NM (United States); Ranade, Satish [New Mexico State Univ., Las Cruces, NM (United States)

    2016-11-01

    In this report we address the challenge of designing efficient protection system for inverter- dominated microgrids. These microgrids are characterised with limited fault current capacity as a result of current-limiting protection functions of inverters. Typically, inverters limit their fault contribution in sub-cycle time frame to as low as 1.1 per unit. As a result, overcurrent protection could fail completely to detect faults in inverter-dominated microgrids. As part of this project a detailed literature survey of existing and proposed microgrid protection schemes were conducted. The survey concluded that there is a gap in the available microgrid protection methods. The only credible protection solution available in literature for low- fault inverter-dominated microgrids is the differential protection scheme which represents a robust transmission-grade protection solution but at a very high cost. Two non-overcurrent protection schemes were investigated as part of this project; impedance-based protection and transient-based protection. Impedance-based protection depends on monitoring impedance trajectories at feeder relays to detect faults. Two communication-based impedance-based protection schemes were developed. the first scheme utilizes directional elements and pilot signals to locate the fault. The second scheme depends on a Central Protection Unit that communicates with all feeder relays to locate the fault based on directional flags received from feeder relays. The later approach could potentially be adapted to protect networked microgrids and dynamic topology microgrids. Transient-based protection relies on analyzing high frequency transients to detect and locate faults. This approach is very promising but its implementation in the filed faces several challenges. For example, high frequency transients due to faults can be confused with transients due to other events such as capacitor switching. Additionally, while detecting faults by analyzing transients

  17. Laboratory testing improves diagnosis and treatment outcomes in primary health care facilities

    Directory of Open Access Journals (Sweden)

    Jane Y. Carter

    2011-12-01

    Full Text Available Objective: To determine if use of basic laboratory tests improves diagnosis and treatment outcomes in outpatients attending rural primary health care facilities.Setting: Six rural health centres in Kenya.Design: Cross-sectional study to observe change in diagnosis and treatment made by clinical officers after laboratory testing in outpatients attending six rural health centres in Kenya.Subject: The diagnosis and treatment of 1134 patients attending outpatient services in six rural health centres were compared before and after basic laboratory testing. Essential clinical diagnostic equipment and laboratory tests were established at each health centre. Clinical officers and laboratory technicians received on-site refresher training in good diagnostic practices and laboratory procedures before the study began.Results: Laboratory tests were ordered on 704 (62.1% patients. Diagnosis and treatment were changed in 45% of tested patients who returned with laboratory results (21% of all patients attending the clinics. 166 (23.5% patients did not return to the clinician for a final diagnosis and management decision after laboratory testing. Blood slide examination for malaria parasites, wet preparations, urine microscopy and stool microscopy resulted in most changes to diagnosis. There was no significant change in drug costs after laboratory testing. The greatest changes in numbers of recorded diseases following laboratory testing was for intestinal worms (53% and malaria (21%.Conclusion: Effective use of basic laboratory tests at primary health care level significantly improves diagnosis and patient treatment. Use of laboratory testing can be readily incorporated into routine clinical practice. On-site refresher training is an effective means of improving the quality of patient care and communication between clinical and laboratory staff.

  18. Laboratory testing during critical care transport: point-of-care testing in air ambulances.

    Science.gov (United States)

    Di Serio, Francesca; Petronelli, Maria Antonia; Sammartino, Eugenio

    2010-07-01

    Air and ground transport are used for prehospital transport of patients in acute life-threatening situations, and increasingly, critically ill patients undergo interhospital transportation. Results from clinical studies suggest that critical tests performed during the transport of critically ill patients presents a potential opportunity to improve patient care. Our project was to identify, according to the recommendations published at this time, a model of point-of-care testing (POCT) (arterial blood gases analysis and glucose, sodium, potassium, ionized calcium, hematocrit/hemoglobin measurements) in air ambulances. In order to identify the key internal and external factors that are important to achieving our objective, an analysis of the Strengths, Weaknesses, Opportunities, and Threats (SWOT analysis) was incorporated into our planning model prior to starting the project. To allow the entire POCT process (pre-, intra-, and post-analytic steps) to be under the control of the reference laboratory, an experimental model of information technology was applied. Real-time results during transport of critically ill patients must be considered to be an integral part of the patient care process and excellent channels of communication are needed between the intensive care units, emergency medical services and laboratories. With technological and computer advances, POCT during critical care transport will certainly increase in the future: this will be a challenge from a laboratory and clinical context.

  19. Summary report - development of laboratory tests and the stress- strain behaviour of Olkiluoto mica gneiss

    Energy Technology Data Exchange (ETDEWEB)

    Hakala, M.; Heikkilae, E. [Helsinki Univ. of Technology, Espoo (Finland). Lab. of Rock Engineering

    1997-05-01

    This work summarizes the project aimed at developing and qualifying a suitable combination of laboratory tests to establish a statistically reliable stress-strain behaviour of the main rock types at Posiva Oy`s detailed investigation sites for disposal of spent nuclear fuel. The work includes literature study of stress-strain behaviour of brittle rock, development and qualification of laboratory tests, suggested test procedures and interpretation methods and finally testing of Olkiluoto mica gneiss. The Olkiluoto study includes over 130 loading tests. Besides the commonly used laboratory tests, direct tensile tests, damage controlled tests and acoustic emission measurements were also carried out. (orig.) (54 refs.).

  20. Maritime DC Microgrids - A Combination of Microgrid Technologies and Maritime Onboard Power System for Future Ships

    DEFF Research Database (Denmark)

    Jin, Zheming; Savaghebi, Mehdi; Quintero, Juan Carlos Vasquez;

    2016-01-01

    system. Not only frequency-related constraints are eliminated, which allows high-speed smaller generators to be used, but also new fault-tolerant configurations involving power electronics, generation control, as well as smart systemic management. For these reasons, DC power systems become natural...... power supply for a short time, which make the system highly consist with DC microgrids. In this content, it is foreseeable that the advanced research outcomes in the field of DC microgrid are also compatible with maritime onboard power systems. In this paper, DC power architectures, control......DC power distribution system is being considered as an attractive alternative to its traditional AC counterpart in many fields of applications and, in particular, for maritime onboard power systems. The adoption of DC power architecture would bring a broad range of benefits to the onboard power...

  1. Microgrid Stability Controller Based on Adaptive Robust Total SMC

    Directory of Open Access Journals (Sweden)

    Xiaoling Su

    2015-03-01

    Full Text Available This paper presents a microgrid stability controller (MSC in order to provide existing distributed generation units (DGs the additional functionality of working in islanding mode without changing their control strategies in grid-connected mode and to enhance the stability of the microgrid. Microgrid operating characteristics and mathematical models of the MSC indicate that the system is inherently nonlinear and time-variable. Therefore, this paper proposes an adaptive robust total sliding-mode control (ARTSMC system for the MSC. It is proved that the ARTSMC system is insensitive to parametric uncertainties and external disturbances. The MSC provides fast dynamic response and robustness to the microgrid. When the system is operating in grid-connected mode, it is able to improve the controllability of the exchanged power between the microgrid and the utility grid, while smoothing the DGs’ output power. When the microgrid is operating in islanded mode, it provides voltage and frequency support, while guaranteeing seamless transition between the two operation modes. Simulation and experimental results show the effectiveness of the proposed approach.

  2. Economic Dispatch for Microgrid Containing Electric Vehicles via Probabilistic Modelling

    Energy Technology Data Exchange (ETDEWEB)

    Yao, Yin; Gao, Wenzhong; Momoh, James; Muljadi, Eduard

    2015-10-06

    In this paper, an economic dispatch model with probabilistic modeling is developed for microgrid. Electric power supply in microgrid consists of conventional power plants and renewable energy power plants, such as wind and solar power plants. Due to the fluctuation of solar and wind plants' output, an empirical probabilistic model is developed to predict their hourly output. According to different characteristics of wind and solar plants, the parameters for probabilistic distribution are further adjusted individually for both power plants. On the other hand, with the growing trend of Plug-in Electric Vehicle (PHEV), an integrated microgrid system must also consider the impact of PHEVs. Not only the charging loads from PHEVs, but also the discharging output via Vehicle to Grid (V2G) method can greatly affect the economic dispatch for all the micro energy sources in microgrid. This paper presents an optimization method for economic dispatch in microgrid considering conventional, renewable power plants, and PHEVs. The simulation results reveal that PHEVs with V2G capability can be an indispensable supplement in modern microgrid.

  3. General Dynamic Equivalent Modeling of Microgrid Based on Physical Background

    Directory of Open Access Journals (Sweden)

    Changchun Cai

    2015-11-01

    Full Text Available Microgrid is a new power system concept consisting of small-scale distributed energy resources; storage devices and loads. It is necessary to employ a simplified model of microgrid in the simulation of a distribution network integrating large-scale microgrids. Based on the detailed model of the components, an equivalent model of microgrid is proposed in this paper. The equivalent model comprises two parts: namely, equivalent machine component and equivalent static component. Equivalent machine component describes the dynamics of synchronous generator, asynchronous wind turbine and induction motor, equivalent static component describes the dynamics of photovoltaic, storage and static load. The trajectory sensitivities of the equivalent model parameters with respect to the output variables are analyzed. The key parameters that play important roles in the dynamics of the output variables of the equivalent model are identified and included in further parameter estimation. Particle Swarm Optimization (PSO is improved for the parameter estimation of the equivalent model. Simulations are performed in different microgrid operation conditions to evaluate the effectiveness of the equivalent model of microgrid.

  4. Microgrids formed by renewable energy integration into power grids pose electrical protection challenges

    OpenAIRE

    Akhtar, Z; Saqib, MA

    2016-01-01

    System parameters of a microgrid change in its two operating modes primarily due to output current limitation of PWM based inverters connected with renewable energy sources. The unavailability of an appropriate protection scheme, which must be compatible with both modes of a microgrid operation, is a major problem in the implementation of a microgrid. Two important properties of the microgrid components are peer-to-peer, and plug-and-play. It means that there is no component like a master con...

  5. Development of New, Low-Head Hydropower Turbine - Modeling & Laboratory Test DE-EE0005426

    Energy Technology Data Exchange (ETDEWEB)

    Krouse, Wayne [Hydro Green Energy, Westmont, IL (United States)

    2014-12-05

    Hydro Green Energy, LLC (HGE) will complete the design, fabrication and laboratory testing of a scaled, vertically stackable, low-head hydropower turbine called the Modular Bulb Turbine (MBT). HGE will also complete a summary report that includes the laboratory testing results and analysis of the tests. Project Goals: Design, model and test modular bulb turbine for installation in numerous HGE low-head hydropower projects at non-powered USACE dams. Project Results: The sub-scale prototype was tested successfully at a leading US hydraulic laboratory. Laboratory data results agreed well with predicted results from numerical modeling.

  6. PEP Support Laboratory Leaching and Permeate Stability Tests

    Energy Technology Data Exchange (ETDEWEB)

    Russell, Renee L.; Peterson, Reid A.; Rinehart, Donald E.; Buchmiller, William C.

    2009-09-25

    Pacific Northwest National Laboratory (PNNL) has been tasked by Bechtel National Inc. (BNI) on the River Protection Project-Hanford Tank Waste Treatment and Immobilization Plant (RPP-WTP) project to perform research and development activities to resolve technical issues identified for the Pretreatment Facility (PTF). The Pretreatment Engineering Platform (PEP) was designed, constructed, and operated as part of a plan to respond to issue M12, "Undemonstrated Leaching Processes," of the External Flowsheet Review Team (EFRT) issue response plan.( ) The PEP is a 1/4.5-scale test platform designed to simulate the WTP pretreatment caustic leaching, oxidative leaching, ultrafiltration solids concentration, and slurry washing processes. The PEP replicates the WTP leaching processes using prototypic equipment and control strategies. A simplified flow diagram of the PEP system is shown in Figure 1.1. Two operating scenarios are currently being evaluated for the ultrafiltration process (UFP) and leaching operations. The first scenario has caustic leaching performed in the UFP-2 ultrafiltration feed vessels (i.e., vessel UFP-VSL-T02A in the PEP and vessels UFP-VSL-00002A and B in the WTP PTF). The second scenario has caustic leaching conducted in the UFP-1 ultrafiltration feed preparation vessels (i.e., vessels UFP-VSL-T01A and B in the PEP and vessels UFP-VSL-00001A and B in the WTP PTF). In both scenarios, 19-M sodium hydroxide solution (NaOH, caustic) is added to the waste slurry in the vessels to leach solid aluminum compounds (e.g., gibbsite, boehmite). Caustic addition is followed by a heating step that uses direct injection of steam to accelerate the leach process. Following the caustic leach, the vessel contents are cooled using vessel cooling jackets and/or external heat exchangers. The main difference between the two scenarios is that for leaching in UFP-VSL-T01A and B, the 19-M NaOH is added to un-concentrated waste slurry (3 to 8 wt% solids), while for leaching in

  7. Laboratory Testing of Magnetic Tracers for Soil Erosion Measurement*1

    Institute of Scientific and Technical Information of China (English)

    HU Guo-Qing; DONG Yuan-Jie; WANG Hui; QIU Xian-Kui; WANG Yan-Hua

    2011-01-01

    Soil erosion, which includes soil detachment, transport, and deposition, is one of the important dynamic land surface processes. The magnetic tracer method is a useful method for studying soil erosion processes. In this study, five types of magnetic tracers were made with fine soil, fly ash, cement, bentonite, and magnetic powder (reduced iron powder) using the method of disk granulation. The tracers were uniformly mixed with soil and tested in the laboratory using simulated rainfall and inflow experiments to simulate the interrill and rill components of soil erosion, in order to select one or more tracers which could be used to study detachment and deposition by the erosive forces of raindrops and surface flow of water on a slope. The results showed that the five types of magnetic tracers with high magnetic susceptibility and a wide range of sizes had a range of 0.99-1.29 gcm-s in bulk density. In the interrill and rill experiments, the tracers FC1 and FC2 which consisted of fly ash and cement at ratios of 1:1 and 2:1, respectively, were transported in phase with soil particles since the magnetic susceptibility of sediment approximated that of the soil which was uneroded and the slopes of the regression equations between the detachment of sediment and magnetic tracers FC1 and FC2 were very close to the expected value of 20, which was the original soil/tracer ratio. The detachment and deposition on slopes could be accurately reflected by the magnetic susceptibility differences. The change in magnetic susceptibility depended on whether deposition or detachment occurred. However, the tracer FS which consisted of fine soil and the tracers FB1 and FB2 which consisted of fly ash and bentonite at ratios of 1:1 and 2:1, respectively, were all unsuitable for soil erosion study since there was no consistent relationship between sediment and tracer detachment for increasing amounts of runoff. Therefore, the tracers FC1 and FC2 could be used to study soil erosion by water.

  8. Application of a microgrid with renewables for a water treatment plant

    DEFF Research Database (Denmark)

    Soshinskaya, Mariya; Graus, Wina; van der Meer, Jos

    2014-01-01

    This research explores the techno-economic potential for a predominantly renewable electricity-based microgrid serving an industrial-sized drink water plant in the Netherlands. Grid-connected and stand-alone microgrid scenarios were modelled, utilizing measured wind speed and solar irradiation data...... important for the cost-effectiveness of a microgrid system....

  9. Symmetrical components and power analysis for a two-phase microgrid system

    DEFF Research Database (Denmark)

    Alibeik, M.; Santos Jr., E. C. dos; Blaabjerg, Frede

    2014-01-01

    This paper presents a mathematical model for the symmetrical components and power analysis of a new microgrid system consisting of three wires and two voltages in quadrature, which is designated as a two-phase microgrid. The two-phase microgrid presents the following advantages: 1) constant power...

  10. Development and Challenge of HIV/AIDS Testing Laboratory Network and Quality Assurance System in China

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    This paper describes the development and challenge of HIV/AIDS testing laboratory network and quality assurance system in China. At present, the HIV/AIDS testing laboratories includes three classes, the National AIDS Reference Laboratory, HIV/AIDS confirmatory laboratories and HIV/AIDS screening laboratories. All of them are accredited by the health authorities, and each class of laboratories take charge of their function strictly according to the "National Management of HIV/AIDS Detection (2006)". A complete quality assurance and quality control system for HIV/AIDS testing has been developed, which includes technical training, strict laboratory monitoring and approval,examination or proficiency testing on HIV/AIDS detection, and quality evaluation and supervision of HIV/AIDS diagnostic kits. Besides conduct the routine anti-HIV antibody test, more and more laboratories began to conduct other tests, such as CD4+ T lymphocyte cell counting, HIV viral load, HIV DNA PCR, genotyping, drug resistance, and HIV-1 recent infection test. The primary challenges faced by the HIV/AIDS testing laboratory network are in the areas of laboratory management and quality control. For example, the provincial PT program is inefficient, the internal quality control is conducted perfunctorily, personnel training can not met the needs of the workplace, which need to be improved.

  11. 10 CFR 707.12 - Specimen collection, handling and laboratory analysis for drug testing.

    Science.gov (United States)

    2010-01-01

    ... drug testing. 707.12 Section 707.12 Energy DEPARTMENT OF ENERGY WORKPLACE SUBSTANCE ABUSE PROGRAMS AT DOE SITES Procedures § 707.12 Specimen collection, handling and laboratory analysis for drug testing... collection to final disposition of specimens, and testing laboratories shall use appropriate cutoff levels in...

  12. 19 CFR 151.73 - Importer's request for commercial laboratory test.

    Science.gov (United States)

    2010-04-01

    ... 19 Customs Duties 2 2010-04-01 2010-04-01 false Importer's request for commercial laboratory test... Hair § 151.73 Importer's request for commercial laboratory test. (a) Conditions for commercial test. If the importer is dissatisfied with the results of a retest made in accordance with § 151.71(c), he...

  13. King County Metro Transit: Allison Hybrid Electric Transit Bus Laboratory Testing

    Energy Technology Data Exchange (ETDEWEB)

    Hayes, R. R.; Williams, A.; Ireland, J.; Walkowicz, K.

    2006-09-01

    Paper summarizes chassis dynamometer testing of two 60-foot articulated transit buses, one conventional and one hybrid, at NREL's ReFUEL Laboratory. It includes experimental setup, test procedures, and results from vehicle testing performed at the NREL ReFUEL laboratory.

  14. 30 CFR 14.21 - Laboratory-scale flame test apparatus.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Laboratory-scale flame test apparatus. 14.21 Section 14.21 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR TESTING... Technical Requirements § 14.21 Laboratory-scale flame test apparatus. The principal parts of the...

  15. 40 CFR Appendix II to Part 1054 - Duty Cycles for Laboratory Testing

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 32 2010-07-01 2010-07-01 false Duty Cycles for Laboratory Testing II Appendix II to Part 1054 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR.... 1054, App. II Appendix II to Part 1054—Duty Cycles for Laboratory Testing (a) Test handheld...

  16. Microgrids: An emerging paradigm for meeting building electricityand heat requirements efficiently and with appropriate energyquality

    Energy Technology Data Exchange (ETDEWEB)

    Marnay, Chris; Firestone, Ryan

    2007-04-10

    The first major paradigm shift in electricity generation,delivery, and control is emerging in the developed world, notably Europe,North America, and Japan. This shift will move electricity supply awayfrom the highly centralised universal service quality model with which weare familiar today towards a more dispersed system with heterogeneousqualities of service. One element of dispersed control is the clusteringof sources and sinks into semi-autonomous mu grids (microgrids).Research, development, demonstration, and deployment (RD3) of mu gridsare advancing rapidly on at least three continents, and significantdemonstrations are currently in progress. This paradigm shift will resultin more electricity generation close to end-uses, often involvingcombined heat and power application for building heating and cooling,increased local integration of renewables, and the possible provision ofheterogeneous qualities of electrical service to match the requirementsof various end-uses. In Europe, mu grid RD3 is entering its third majorround under the 7th European Commission Framework Programme; in the U.S.,one specific mu grid concept is undergoing rigorous laboratory testing,and in Japan, where the most activity exists, four major publiclysponsored and two privately sponsored demonstrations are in progress.This evolution poses new challenges to the way buildings are designed,built, and operated. Traditional building energy supply systems willbecome much more complex in at least three ways: 1. one cannot simplyassume gas arrives at the gas meter, electricity at its meter, and thetwo systems are virtually independent of one another; rather, energyconversion, heat recovery and use, and renewable energy harvesting mayall be taking place simultaneously within the building energy system; 2.the structure of energy flows in the building must accommodate multipleenergy processes in a manner that permits high overall efficiency; and 3.multiple qualities of electricity may be supplied to

  17. Laboratory test of source encapsulation for decreasing PCB concentrations

    DEFF Research Database (Denmark)

    Kolarik, Barbara; Andersen, Helle Vibeke; Markowicz, Pawel

    2016-01-01

    This study investigates the effect of encapsulation of tertiary PCB sources with PERMASORB™ Adsorber Wallpaper and the surface emissions trap (cTrap) on indoor air concentration of PCBs and on the PCB content in the source. The 40 weeks long laboratory investigation shows reduction of the air...

  18. 78 FR 59946 - Current List of Laboratories and Instrumented Initial Testing Facilities Which Meet Minimum...

    Science.gov (United States)

    2013-09-30

    ... Public Law 100-71. The ``Mandatory Guidelines for Federal Workplace Drug Testing Programs,'' as amended... Partnership, 245 Pall Mall Street, London, ONT, Canada N6A 1P4, 519-679-1630. Laboratory Corporation of...: Centinela Hospital Airport Toxicology Laboratory). Pathology Associates Medical Laboratories, 110 West Cliff...

  19. Determination of basic friction angle using various laboratory tests.

    Science.gov (United States)

    Jang, Bo-An

    2016-04-01

    The basic friction angle of rock is an important factor of joint shear strength and is included within most shear strength criteria. It can be measured by direct shear test, triaxial compression test and tilt test. Tilt test is mostly used because it is the simplest method. However, basic friction angles measured using tilt test for same rock type or for one sample are widely distributed and often do not show normal distribution. In this research, the basic friction angles for the Hangdeung granite form Korea and Berea sandstone from USA are measured accurately using direct shear test and triaxial compression test. Then basic friction angles are again measured using tilt tests with various conditions and are compared with those measured using direct shear test and triaxial compression test to determine the optimum condition of tilt test. Three types of sliding planes, such as planes cut by saw and planes polished by #100 and #600 grinding powders, are prepared. When planes are polished by #100 grinding powder, the basic friction angles measured using direct shear test and triaxial compression test are very consistent and show narrow ranges. However, basic friction angles show wide ranges when planes are cut by saw and are polished by #600 grinding powder. The basic friction angle measured using tilt test are very close to those measured using direct shear test and triaxial compression test when plane is polished by #100 grinding powder. When planes are cut by saw and are polished by #600 grinding powder, basic friction angles measured using tilt test are slightly different. This indicates that tilt test with plane polished by #100 grinding powder can yield an accurate basic friction angle. In addition, the accurate values are obtained not only when planes are polished again after 10 times of tilt test, but values are averaged by more 30 times of tests.

  20. The rapid plasma reagin test cannot replace the venereal disease research laboratory test for neurosyphilis diagnosis.

    Science.gov (United States)

    Marra, Christina M; Tantalo, Lauren C; Maxwell, Clare L; Ho, Emily L; Sahi, Sharon K; Jones, Trudy

    2012-06-01

    The cerebrospinal fluid (CSF) Venereal Disease Research Laboratory (VDRL) test is a mainstay for neurosyphilis diagnosis, but it lacks diagnostic sensitivity and is logistically complicated. The rapid plasma reagin (RPR) test is easier to perform, but its appropriateness for use on CSF is controversial. RPR reactivity was determined for CSF from 149 individuals with syphilis using 2 methods. The CSF-RPR was performed according to the method for serum. The CSF-RPR-V was performed using the method recommended for the CSF-VDRL. Laboratory-defined neurosyphilis included reactive CSF-fluorescent treponemal antibody absorption test and CSF white blood cells >20/uL. Symptomatic neurosyphilis was defined as vision loss or hearing loss. CSF-VDRL was reactive in 45 (30.2%) patients. Of these, 29 (64.4%) were CSF-RPR reactive and 37 (82.2%) were CSF-RPR-V reactive. There were no instances where the CSF-VDRL was nonreactive but the CSF-RPR or CSF-RPR-V was reactive. Among the 28 samples that were reactive in all 3 tests, CSF-VDRL titers (median [IQR], 1:4 [1:4-1:16]) were significantly higher than CSF-RPR (1:2 [1:1-1:4], P = 0.0002) and CSF-RPR-V titers (1:4 [1:2-1:8], P = 0.01). The CSF RPR and the CSF-RPR-V tests had lower sensitivities than the CSF-VDRL: 56.4% and 59.0% versus 71.8% for laboratory-diagnosed neurosyphilis and 51.5% and 57.6% versus 66.7% for symptomatic neurosyphilis. Compared with the CSF-VDRL, the CSF-RPR has a high false-negative rate, thus not improving upon this known limitation of the CSF-VDRL for neurosyphilis diagnosis. Adapting the RPR procedure to mimic the CSF-VDRL decreased, but did not eliminate, the number of false negatives and did not avoid all the logistical complications of the CSF-VDRL.

  1. Laboratory test and acoustic analysis of cabin treatment for propfan test assessment aircraft

    Science.gov (United States)

    Kuntz, H. L.; Gatineau, R. J.

    1991-01-01

    An aircraft cabin acoustic enclosure, built in support of the Propfan Test Assessment (PTA) program, is described. Helmholtz resonators were attached to the cabin trim panels to increase the sidewall transmission loss (TL). Resonators (448) were located between the trim panels and fuselage shell. In addition, 152 resonators were placed between the enclosure and aircraft floors. The 600 resonators were each tuned to a 235 Hz resonance frequency. After flight testing on the PTA aircraft, the enclosure was tested in the Kelly Johnson R and D Center Acoustics Lab. Laboratory noise reduction (NR) test results are discussed. The enclosure was placed in a Gulfstream 2 fuselage section. Broadband (138 dB overall SPL) and tonal (149 dB overall SPL) excitations were used in the lab. Tonal excitation simulated the propfan flight test excitation. The fundamental tone was stepped in 2 Hz intervals from 225 through 245 Hz. The resonators increase the NR of the cabin walls around the resonance frequency of the resonator array. The effects of flanking, sidewall absorption, cabin adsorption, resonator loading of trim panels, and panel vibrations are presented. Increases in NR of up to 11 dB were measured.

  2. Materials and Nondestructive Evaluation Laboratoriers: User Test Planning Guide

    Science.gov (United States)

    Schaschl, Leslie

    2011-01-01

    The Materials and Nondestructive Evaluation Laboratory process, milestones and inputs are unknowns to first-time users. The Materials and Nondestructive Evaluation Laboratory Planning Guide aids in establishing expectations for both NASA and non- NASA facility customers. The potential audience for this guide includes both internal and commercial spaceflight hardware developers. It is intended to assist their project engineering personnel in materials analysis planning and execution. Material covered includes a roadmap of the analysis process, roles and responsibilities of facility and user, major milestones, facility capabilities, and inputs required by the facility. Samples of deliverables, products, and inputs necessary to define scope of analysis, cost, and schedule are included as an appendix to the guide.

  3. Maintaining data quality in an environmental testing laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Cohen, Roy J.

    2001-03-05

    In today's competitive and highly litigious world, it is critical that any laboratory generating data for the environmental and allied industries have a world-class Quality Assurance Program. This Plan must conform to the requirements of every agency and client with whom the lab does business. The goal of such a program is data defensibility; i.e., data validity. Data (usually qualitative analyte [compound or element] identifications and quantitative numerical results) are the end results of nearly all analytical laboratory processes, and the source of revenue. Clients pay for results. The clients expect the results to be accurate, precise, and repeatable. If their data has to go to court, the laboratory will be called upon to defend the accuracy and precision of their work. Without a strong QA program, this will be impossible. The potential implications and repercussions of non-defensible lab data are far-reaching and very costly in terms of loss of future revenues and in legal judgments.

  4. Antimicrobial Testing Methods & Procedures Developed by EPA's Microbiology Laboratory

    Science.gov (United States)

    We develop antimicrobial testing methods and standard operating procedures to measure the effectiveness of hard surface disinfectants against a variety of microorganisms. Find methods and procedures for antimicrobial testing.

  5. Power management of remote microgrids considering battery lifetime

    Science.gov (United States)

    Chalise, Santosh

    Currently, 20% (1.3 billion) of the world's population still lacks access to electricity and many live in remote areas where connection to the grid is not economical or practical. Remote microgrids could be the solution to the problem because they are designed to provide power for small communities within clearly defined electrical boundaries. Reducing the cost of electricity for remote microgrids can help to increase access to electricity for populations in remote areas and developing countries. The integration of renewable energy and batteries in diesel based microgrids has shown to be effective in reducing fuel consumption. However, the operational cost remains high due to the low lifetime of batteries, which are heavily used to improve the system's efficiency. In microgrid operation, a battery can act as a source to augment the generator or a load to ensure full load operation. In addition, a battery increases the utilization of PV by storing extra energy. However, the battery has a limited energy throughput. Therefore, it is required to provide balance between fuel consumption and battery lifetime throughput in order to lower the cost of operation. This work presents a two-layer power management system for remote microgrids. First layer is day ahead scheduling, where power set points of dispatchable resources were calculated. Second layer is real time dispatch, where schedule set points from the first layer are accepted and resources are dispatched accordingly. A novel scheduling algorithm is proposed for a dispatch layer, which considers the battery lifetime in optimization and is expected to reduce the operational cost of the microgrid. This method is based on a goal programming approach which has the fuel and the battery wear cost as two objectives to achieve. The effectiveness of this method was evaluated through a simulation study of a PV-diesel hybrid microgrid using deterministic and stochastic approach of optimization.

  6. FRACTIONAL CRYSALLIZATION LABORATORY TESTS WITH SIMULATED TANK WASTE

    Energy Technology Data Exchange (ETDEWEB)

    HERTING DL

    2007-11-29

    Results are presented for several simulated waste tests related to development of the fractional crystallization process. Product salt dissolution rates were measured to support pilot plant equipment design. Evaporation tests were performed to evaluate the effects of organics on slurry behavior and to determine optimum antifoam addition levels. A loss-of-power test was performed to support pilot plant accident scenario analysis. Envelope limit tests were done to address variations in feed composition.

  7. Laboratory tests of headache disorders - dawn of a new era?

    DEFF Research Database (Denmark)

    Schytz, Henrik Winther; Olesen, Jes

    2017-01-01

    and some secondary headaches. BACKGROUND: In this narrative review we present and discuss published tests that might be useful in phenotyping and/or diagnosis of long-lasting headache disorders such as migraine, tension-type headache, trigeminal autonomic cephalalgias, trigeminal neuralgia and persisting...... secondary headaches. AIM: The palpometer test, quantitative sensory testing, nociceptive blink reflex and autonomic tests may be valuable to phenotype and/or diagnose subforms of migraine, tension-type headache, cluster headache, trigeminal neuralgia and medication-overuse headache. Provocation tests...

  8. Data reproducibility of pace strategy in a laboratory test run

    Science.gov (United States)

    de França, Elias; Xavier, Ana Paula; Hirota, Vinicius Barroso; Côrrea, Sônia Cavalcanti; Caperuto, Érico Chagas

    2016-01-01

    This data paper contains data related to a reproducibility test for running pacing strategy in an intermittent running test until exhaustion. Ten participants underwent a crossover study (test and retest) with an intermittent running test. The test was composed of three-minute sets (at 1 km/h above Onset Blood Lactate Accumulation) until volitional exhaustion. To assess pace strategy change, in the first test participants chose the rest time interval (RTI) between sets (ranging from 30 to 60 s) and in the second test the maximum RTI values were either the RTI chosen in the first test (maximum RTI value), or less if desired. To verify the reproducibility of the test, rating perceived exertion (RPE), heart rate (HR) and blood plasma lactate concentration ([La]p) were collected at rest, immediately after each set and at the end of the tests. As results, RTI, RPE, HR, [La]p and time to exhaustion were not statistically different (p>0.05) between test and retest, as well as they demonstrated good intraclass correlation. PMID:27081672

  9. 微电网关键技术实践及实验%Practice and experiment of the key microgrid technologies

    Institute of Scientific and Technical Information of China (English)

    李瑞生

    2013-01-01

      针对微电网运行稳定问题,介绍了高渗透率独立微电网三态控制技术、微电网并离网控制技术、微电网运行技术。给出了独立微电网三态控制系统图,微电网稳态恒频恒压控制策略及软件实现流程,微电网动态切机减载控制策略及软件实现流程。提出了微电网暂态故障保护方案以及微电网并网控制逻辑和并网转离网切换的“无缝”及相关实现手段,同时搭建高渗透率独立微电网的物理模型并提出了相关实验方案。将该技术及策略应用于实际的微电网工程及微电网物理模型试验平台中验证,结果表明该关键技术及策略是可行的。%In respect to the problem of microgrid steady operation, this paper recommends tri-state control technology of high penetration isolated microgrid, microgrid grid-connected and off control technology, and microgrid operation technology. This paper provides the system diagram of the microgrid tri-state control system, steady state constant-frequency and constant-voltage control strategy of micogrid, software realization procedure, dynamic cutting machine load shedding control strategy and control flowchart. Furthermore, it proposes the microgrid transient fault protection strategy and grid-connected control logic and seamless ON/OFF switch and the relevant realization strategy. Meanwhile, the physical model of high penetration isolated microgrid is established and relevant experimental scheme is introduced. The proposed technology and strategy are applied to real microgrid project and the validation of the physical model test platform. The results show that the key technologies and strategy are feasible.

  10. Intelligent energy management control for independent microgrid

    Indian Academy of Sciences (India)

    T BOGARAJ; J KANAKARAJ

    2016-07-01

    This work presents a new adaptive scheme for energy management in an independent microgrid.The proposed energy management system has been developed to manage the utilization of power among the hybrid resources and energy storage system in order to supply the load requirement based on multi-agent system (MAS) concept and predicted renewable powers and load powers. Auto regressive moving average models have been developed for predicting the wind speed, atmospheric temperature, irradiation, and connected loads. The structure proposed in this paper includes renewable sources as primary source and storage system as secondary source. A wind generator and solar PV array system together acts as primary source, which supplies power to the local load most of the time in this energy management strategy. When they fail to meet the load demand, the secondary source present in the system will assist the primary source and help to attain the goal of satisfying load demand without interruption. If the primary source and secondary source together are not able to meet the load demand then load shedding will be executed according to the priority set. Thus the developed MAS algorithm co-ordinates the hybrid system components and achieves energy management among renewableenergy sources, storage units, and load under varying environmental conditions and varying loads. STATCOM based compensation has been implemented to balance the reactive power demand and to mitigate the voltage fluctuations and harmonics on the AC bus. The proposed microgrid has been simulated with MAS concept in Matlab/Simulink environment. The results presented in this paper show cases the effectiveness of the proposed energy management controller.

  11. [Ayurvedics drugs in France. Laboratories polytherapic, a test].

    Science.gov (United States)

    Raynal, Cécile; Lefebvre, Thierry

    2011-02-01

    In the beginning of the thirties, Dr Jean Saidman, who has already created a rotative solarium at Aix-les-Bains, built another one in Jamnagar (India). When he was there, he discovered ayurvedic therapy. After the Second World War, with his friends Dr Rémus Krainik and the chemist René-Henri Monceaux, he set up a "néo-ayurvedic action committee", and then a pharmaceutical laboratory, "Polythérapic", to export to french colonies patents medicines inspired by indian medicine. The authors tale this experience suddenly stopped by the unexpected death of Jean Saidman, in 1949.

  12. Tonopah test range - outpost of Sandia National Laboratories

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, L.

    1996-03-01

    Tonopah Test Range is a unique historic site. Established in 1957 by Sandia Corporation, Tonopah Test Range in Nevada provided an isolated place for the Atomic Energy Commission to test ballistics and non-nuclear features of atomic weapons. It served this and allied purposes well for nearly forty years, contributing immeasurably to a peaceful conclusion to the long arms race remembered as the Cold War. This report is a brief review of historical highlights at Tonopah Test Range. Sandia`s Los Lunas, Salton Sea, Kauai, and Edgewood testing ranges also receive abridged mention. Although Sandia`s test ranges are the subject, the central focus is on the people who managed and operated the range. Comments from historical figures are interspersed through the narrative to establish this perspective, and at the end a few observations concerning the range`s future are provided.

  13. Impact of Medical School Laboratory Courses and Physician Attitude on Test Use by House Staff.

    Science.gov (United States)

    Everett, George D.; And Others

    1983-01-01

    A study to assess the impact of laboratory courses in medical school on subsequent University of Iowa house staff test use, and to assess the influence of attitudinal factors on test use patterns is reported. Physician preferences for style, format, and timing of laboratory training sessions are examined. (MSE)

  14. 78 FR 22536 - Procedural Manual for the Election Assistance Commission's Voting System Test Laboratories...

    Science.gov (United States)

    2013-04-16

    ... COMMISSION Procedural Manual for the Election Assistance Commission's Voting System Test Laboratories Program Manual, Version 2.0 AGENCY: United States Election Assistance Commission (EAC). ACTION: Notice; publication of Voting System Test Laboratories Program Manual, Version 2.0, for 60 day public comment...

  15. Idaho National Engineering Laboratory, Test Area North, Hangar 629 -- Photographs, written historical and descriptive data

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-12-31

    The report describes the history of the Idaho National Engineering Laboratory`s Hangar 629. The hangar was built to test the possibility of linking jet engine technology with nuclear power. The history of the project is described along with the development and eventual abandonment of the Flight Engine Test hangar. The report contains historical photographs and architectural drawings.

  16. 75 FR 51280 - Oversight of Laboratory Developed Tests; Public Meeting; Reopening of the Comment Period

    Science.gov (United States)

    2010-08-19

    ... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration Oversight of Laboratory Developed Tests; Public Meeting... oversight of laboratory developed tests (LDTs). FDA is reopening the comment period to update comments...

  17. 42 CFR 493.1467 - Condition: Laboratories performing high complexity testing; cytology general supervisor.

    Science.gov (United States)

    2010-10-01

    ... testing; cytology general supervisor. 493.1467 Section 493.1467 Public Health CENTERS FOR MEDICARE....1467 Condition: Laboratories performing high complexity testing; cytology general supervisor. For the subspecialty of cytology, the laboratory must have a general supervisor who meets the qualification...

  18. From laboratory corrosion tests to a corrosion lifetime for wood fasteners : progress and challenges

    Science.gov (United States)

    Samuel L. Zelinka; Dominique Derome; Samuel V. Glass

    2010-01-01

    Determining a “corrosion-lifetime” for fasteners embedded in wood treated with recently adopted preservative systems depends upon successfully relating results of laboratory tests to in-service conditions. In contrast to laboratory tests where metal is embedded in wood at constant temperature and moisture content, the in-service temperature and moisture content of wood...

  19. Effects of earthquake induced rock shear on containment system integrity. Laboratory testing plan development

    Energy Technology Data Exchange (ETDEWEB)

    Read, Rodney S. (RSRead Consulting Inc. (Canada))

    2011-07-15

    This report describes a laboratory-scale testing program plan to address the issue of earthquake induced rock shear effects on containment system integrity. The document contains a review of relevant literature from SKB covering laboratory testing of bentonite clay buffer material, scaled analogue tests, and the development of related material models to simulate rock shear effects. The proposed testing program includes standard single component tests, new two-component constant volume tests, and new scaled analogue tests. Conceptual drawings of equipment required to undertake these tests are presented along with a schedule of tests. The information in this document is considered sufficient to engage qualified testing facilities, and to guide implementation of laboratory testing of rock shear effects. This document was completed as part of a collaborative agreement between SKB and Nuclear Waste Management Organization (NWMO) in Canada

  20. Reactivity of microhemagglutination, fluorescent treponemal antibody absorption, and venereal disease research laboratory tests in primary syphilis.

    Science.gov (United States)

    Dyckman, J D; Storms, S; Huber, T W

    1980-10-01

    Seroreactivity in 130 cases of primary syphilis was 91.5% by fluorescent treponemal antibody absorption test, 82.3% by microhemagglutination (MHA-TP test), and 68.5% by the Venereal Disease Reseach Laboratory (VDRL) test. The MHA TP test generally became reactive earlier than the VDRL test and confirmed all reactive and most weakly reactive VDRL results.

  1. Control of hybrid AC/DC microgrid under islanding operational conditions

    DEFF Research Database (Denmark)

    Ding, G.; Gao, F.; Zhang, S.

    2014-01-01

    This paper presents control methods for hybrid AC/DC microgrid under islanding operation condition. The control schemes for AC sub-microgrid and DC sub-microgrid are investigated according to the power sharing requirement and operational reliability. In addition, the key control schemes...... of interlinking converter with DC-link capacitor or energy storage, which will devote to the proper power sharing between AC and DC sub-microgrids to maintain AC and DC side voltage stable, is reviewed. Combining the specific control methods developed for AC and DC sub-microgrids with interlinking converter......, the whole hybrid AC/DC microgrid can manage the power flow transferred between sub-microgrids for improving on the operational quality and efficiency....

  2. Optimal Power Scheduling for a Grid-Connected Hybrid PV-Wind-Battery Microgrid System

    DEFF Research Database (Denmark)

    Hernández, Adriana Carolina Luna; Aldana, Nelson Leonardo Diaz; Savaghebi, Mehdi

    2016-01-01

    In this paper, a lineal mathematical model is proposed to schedule optimally the power references of the distributed energy resources in a grid-connected hybrid PVwind-battery microgrid. The optimization of the short term scheduling problem is addressed through a mixed-integer linear programming...... mathematical model, wherein the cost of energy purchased from the main grid is minimized and profits for selling energy generated by photovoltaic arrays are maximized by considering both physical constraints and requirements for a feasible deployment in the real system. The optimization model is tested...

  3. Optimal power flow based on glow worm-swarm optimization for three-phase islanded microgrids

    DEFF Research Database (Denmark)

    Quang, Ninh Nguyen; Sanseverino, Eleonora Riva; Di Silvestre, Maria Luisa

    2014-01-01

    This paper presents an application of the Glowworm Swarm Optimization method (GSO) to solve the optimal power flow problem in three-phase islanded microgrids equipped with power electronics dc-ac inverter interfaced distributed generation units. In this system, the power injected by the distributed...... generation units and the droop control parameters are considered as variables to be adjusted by a superior level control. Two case studies with different optimized parameters have been carried out on a 6-bus test system. The obtained results showed the effectiveness of the proposed approach and overcomes...

  4. Online Energy Management System for Distributed Generators in a Grid-Connected Microgrid

    DEFF Research Database (Denmark)

    Hernández, Adriana Carolina Luna; Aldana, Nelson Leonardo Diaz; Graells, Moises

    2015-01-01

    that feeds a critical load. The optimization problem aims to minimize the operating cost while maximizing the power provided by the renewable energy sources. The power references for the distributed energy resources (DER) are scheduled by using CPLEX solver which uses as input current measurements, stored...... data and adjusted weather forecast data previously scaled in each iteration considering the current status. The proposed structure is tested in a real time simulation platform (dSPACE 1006) for the microgrid model, by using Labview to data acquisition and Matlab to implement the energy management...

  5. Bonding to oxide ceramics—laboratory testing versus clinical outcome.

    Science.gov (United States)

    Kern, Matthias

    2015-01-01

    Despite a huge number of published laboratory bonding studies on dental oxide ceramics clinical long-term studies on resin bonded oxide ceramic restorations are rare. The purpose of this review is to present the best available clinical evidence for successful bonding of dental oxide ceramic restorations. Clinical trials with resin-bonded restorations that had no or only limited mechanical retention and were made from alumina or zirconia ceramic were identified using an electronic search in PubMed database. Overall 10 publications with clinical trials could be identified. Their clinical outcome was compared with that laboratory bond strength studies. Clinical data provide strong evidence that air-abrasion at a moderate pressure in combination with using phosphate monomer containing primers and/or luting resins provide long-term durable bonding to glass-infiltrated alumina and zirconia ceramic under the humid and stressful oral conditions. As simple and clinically reliable bonding methods to oxide ceramics exist, the rationale for development of alternative bonding methods might be reconsidered especially when these methods are more time consuming or require rather complicated and/or technique sensitive procedures. Copyright © 2014 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  6. PEP Support: Laboratory Scale Leaching and Permeate Stability Tests

    Energy Technology Data Exchange (ETDEWEB)

    Russell, Renee L.; Peterson, Reid A.; Rinehart, Donald E.; Buchmiller, William C.

    2010-05-21

    This report documents results from a variety of activities requested by the Hanford Tank Waste Treatment and Immobilization Plant (WTP). The activities related to caustic leaching, oxidative leaching, permeate precipitation behavior of waste as well as chromium (Cr) leaching are: • Model Input Boehmite Leaching Tests • Pretreatment Engineering Platform (PEP) Support Leaching Tests • PEP Parallel Leaching Tests • Precipitation Study Results • Cr Caustic and Oxidative Leaching Tests. Leaching test activities using the PEP simulant provided input to a boehmite dissolution model and determined the effect of temperature on mass loss during caustic leaching, the reaction rate constant for the boehmite dissolution, and the effect of aeration in enhancing the chromium dissolution during caustic leaching. Other tests were performed in parallel with the PEP tests to support the development of scaling factors for caustic and oxidative leaching. Another study determined if precipitate formed in the wash solution after the caustic leach in the PEP. Finally, the leaching characteristics of different chromium compounds under different conditions were examined to determine the best one to use in further testing.

  7. Optimization of backfill pellet properties AASKAR DP2 - Laboratory tests

    Energy Technology Data Exchange (ETDEWEB)

    Andersson, Linus; Sanden, Torbjoern [Clay Technology AB, Lund (Sweden)

    2012-12-15

    Bentonite pellets are planned to be used as a part of the backfill in the Swedish spent nuclear fuel deep repository concept KBS-3. This report describes testing and evaluation of different backfill pellet candidates. The work completed included testing of both pellet material and pellet type. The materials tested were sourced from India (ASHA), Greece (IBECO, 2 products) and Wyoming USA (MX-80 clay). The majority of the tests were completed on the ASHA clay as well as the IBECO-RWC-BF products, with only limited testing of the others. The pellets tested were manufactured using both extrusion and roller compaction techniques and had different sizes and geometries. The following tests have been performed and are presented in this report: 1. General tests. Water content, bulk density and dry density have been determined for both the pellet filling and the individual pellets. The compressibility of the pellet filling was tested with CRS-tests and the strength of the individual pellets was tested with a special compression test. The water content varied from 11.3% to 18.7% and was highest for the extruded pellets. The dry density was somewhat higher for the roller-compacted pellets and their compressibility was lower. The strength of the individual pellets was generally higher for the extruded pellets. 2. Erosion. The pellet filling will be exposed to groundwater inflow when installed in the tunnel. This flow could possibly cause significant erosion on the pellet filling. Erosion tests have been performed with comparisons in erosion resistance made on the various material- and pellet-types. The influence of variations in water salinity and flow rates was also tested. The IBECO extruded 6- and 10- mm diameter rods and the compacted Posiva spec.-A pellet filling seem to have the lowest tendency to erode. It is also the IBECO extruded pellet filling that withstands variations in water salinity and flow rates best. 3. Water storing capacity. The pellet filling

  8. DC Microgrids Scoping Study. Estimate of Technical and Economic Benefits

    Energy Technology Data Exchange (ETDEWEB)

    Backhaus, Scott N. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Swift, Gregory William [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Chatzivasileiadis, Spyridon [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Tschudi, William [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Glover, Steven [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Starke, Michael [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Wang, Jianhui [Argonne National Lab. (ANL), Argonne, IL (United States); Yue, Meng [Brookhaven National Lab. (BNL), Upton, NY (United States); Hammerstrom, Donald [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2015-03-23

    Microgrid demonstrations and deployments are expanding in US power systems and around the world. Although goals are specific to each site, these microgrids have demonstrated the ability to provide higher reliability and higher power quality than utility power systems and improved energy utilization. The vast majority of these microgrids are based on AC power transfer because this has been the traditionally dominant power delivery scheme. Independently, manufacturers, power system designers and researchers are demonstrating and deploying DC power distribution systems for applications where the end-use loads are natively DC, e.g., computers, solid-state lighting, and building networks. These early DC applications may provide higher efficiency, added flexibility, reduced capital costs over their AC counterparts. Further, when onsite renewable generation, electric vehicles and storage systems are present, DC-based microgrids may offer additional benefits. Early successes from these efforts raises a question - can a combination of microgrid concepts and DC distribution systems provide added benefits beyond what has been achieved individually?

  9. Application of Model Predictive Control to BESS for Microgrid Control

    Directory of Open Access Journals (Sweden)

    Thai-Thanh Nguyen

    2015-08-01

    Full Text Available Battery energy storage systems (BESSs have been widely used for microgrid control. Generally, BESS control systems are based on proportional-integral (PI control techniques with the outer and inner control loops based on PI regulators. Recently, model predictive control (MPC has attracted attention for application to future energy processing and control systems because it can easily deal with multivariable cases, system constraints, and nonlinearities. This study considers the application of MPC-based BESSs to microgrid control. Two types of MPC are presented in this study: MPC based on predictive power control (PPC and MPC based on PI control in the outer and predictive current control (PCC in the inner control loops. In particular, the effective application of MPC for microgrids with multiple BESSs should be considered because of the differences in their control performance. In this study, microgrids with two BESSs based on two MPC techniques are considered as an example. The control performance of the MPC used for the control microgrid is compared to that of the PI control. The proposed control strategy is investigated through simulations using MATLAB/Simulink software. The simulation results show that the response time, power and voltage ripples, and frequency spectrum could be improved significantly by using MPC.

  10. Optimal control in microgrid using multi-agent reinforcement learning.

    Science.gov (United States)

    Li, Fu-Dong; Wu, Min; He, Yong; Chen, Xin

    2012-11-01

    This paper presents an improved reinforcement learning method to minimize electricity costs on the premise of satisfying the power balance and generation limit of units in a microgrid with grid-connected mode. Firstly, the microgrid control requirements are analyzed and the objective function of optimal control for microgrid is proposed. Then, a state variable "Average Electricity Price Trend" which is used to express the most possible transitions of the system is developed so as to reduce the complexity and randomicity of the microgrid, and a multi-agent architecture including agents, state variables, action variables and reward function is formulated. Furthermore, dynamic hierarchical reinforcement learning, based on change rate of key state variable, is established to carry out optimal policy exploration. The analysis shows that the proposed method is beneficial to handle the problem of "curse of dimensionality" and speed up learning in the unknown large-scale world. Finally, the simulation results under JADE (Java Agent Development Framework) demonstrate the validity of the presented method in optimal control for a microgrid with grid-connected mode.

  11. A Robust Load Shedding Strategy for Microgrid Islanding Transition

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Guodong [ORNL; Xiao, Bailu [ORNL; Starke, Michael R [ORNL; Ceylan, Oguzhan [ORNL; Tomsovic, Kevin [University of Tennessee, Knoxville (UTK)

    2016-01-01

    A microgrid is a group of interconnected loads and distributed energy resources. It can operate in either gridconnected mode to exchange energy with the main grid or run autonomously as an island in emergency mode. However, the transition of microgrid from grid-connected mode to islanded mode is usually associated with excessive load (or generation), which should be shed (or spilled). Under this condition, this paper proposes an robust load shedding strategy for microgrid islanding transition, which takes into account the uncertainties of renewable generation in the microgrid and guarantees the balance between load and generation after islanding. A robust optimization model is formulated to minimize the total operation cost, including fuel cost and penalty for load shedding. The proposed robust load shedding strategy works as a backup plan and updates at a prescribed interval. It assures a feasible operating point after islanding given the uncertainty of renewable generation. The proposed algorithm is demonstrated on a simulated microgrid consisting of a wind turbine, a PV panel, a battery, two distributed generators (DGs), a critical load and a interruptible load. Numerical simulation results validate the proposed algorithm.

  12. Test Results From The Idaho National Laboratory 15kW High Temperature Electrolysis Test Facility

    Energy Technology Data Exchange (ETDEWEB)

    Carl M. Stoots; Keith G. Condie; James E. O' Brien; J. Stephen Herring; Joseph J. Hartvigsen

    2009-07-01

    A 15kW high temperature electrolysis test facility has been developed at the Idaho National Laboratory under the United States Department of Energy Nuclear Hydrogen Initiative. This facility is intended to study the technology readiness of using high temperature solid oxide cells for large scale nuclear powered hydrogen production. It is designed to address larger-scale issues such as thermal management (feed-stock heating, high temperature gas handling, heat recuperation), multiple-stack hot zone design, multiple-stack electrical configurations, etc. Heat recuperation and hydrogen recycle are incorporated into the design. The facility was operated for 1080 hours and successfully demonstrated the largest scale high temperature solid-oxide-based production of hydrogen to date.

  13. Effectiveness of a computerized alert system based on re-testing intervals for limiting the inappropriateness of laboratory test requests.

    Science.gov (United States)

    Lippi, Giuseppe; Brambilla, Marco; Bonelli, Patrizia; Aloe, Rosalia; Balestrino, Antonio; Nardelli, Anna; Ceda, Gian Paolo; Fabi, Massimo

    2015-11-01

    There is consolidated evidence that the burden of inappropriate laboratory test requests is very high, up to 70%. We describe here the function of a computerized alert system linked to the order entry, designed to limit the number of potentially inappropriate laboratory test requests. A computerized alert system based on re-testing intervals and entailing the generation of pop-up alerts when preset criteria of appropriateness for 15 laboratory tests were violated was implemented in two clinical wards of the University Hospital of Parma. The effectiveness of the system for limiting potentially inappropriate tests was monitored for 6months. Overall, 765/3539 (22%) test requests violated the preset criteria of appropriateness and generated the appearance of electronic alert. After alert appearance, 591 requests were annulled (17% of total tests requested and 77% of tests alerted, respectively). The total number of test requests violating the preset criteria of inappropriateness constantly decreased over time (26% in the first three months of implementation versus 17% in the following period; ptest withdrawn was 3387 Euros (12.8% of the total test cost) throughout the study period. The results of this study suggest that a computerized alert system may be effective to limit the inappropriateness of laboratory test requests, generating significant economic saving and educating physicians to a more efficient use of laboratory resources. Copyright © 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  14. Laboratory Testing of Cyclic Laterally Loaded Pile in Cohesionless Soil

    DEFF Research Database (Denmark)

    Roesen, Hanne Ravn; Ibsen, Lars Bo; Hansen, Mette;

    2013-01-01

    Offshore wind turbines are normally founded with large diameter monopiles and placed in rough environments subjected to variable lateral loads from wind and waves. A long-term lateral loading may create rotation (tilt) of the pile by change in the pile-soil system which is critical...... in the serviceability limit state. In this paper small-scale testing of a pile subjected to cyclic, lateral loading is treated in order to investigate the effect of cyclic loading. The test setup, which is an improvement of a previous setup, is described and the first results of testing are compared with previous...

  15. Microbiological examination and proficiency testing in dairy laboratories.

    Science.gov (United States)

    Teger, S G

    2001-03-01

    This paper considers the main factors in the assessment of microbiological examination of food and discusses a few points related to validation of quantitative and qualitative microbiological methods. Within the scope of accredited methods, the author defines the terms such as conform reference, equivalence of reference method, and in-house method. The paper describes evaluation of a routine method with respect to the official method based on results obtained by automatic epifluorescent microscopy using the BactoScan 8000 instrument for determination of bacteriological quality of milk and provides general guidance for the establishment of a conversion relationship between the two methods. The paper gives an overview of the quality assurance aspects involved in the application of the routine method and concludes with an example of interlaboratory proficiency study for the epifluorescent microscopic method which is regularly applied in dairy laboratories.

  16. Convergence Analysis of Distributed Control for Operation Cost Minimization of Droop Controlled DC Microgrid Based on Multiagent

    DEFF Research Database (Denmark)

    Li, Chendan; Quintero, Juan Carlos Vasquez; Guerrero, Josep M.

    2016-01-01

    In this paper we present a distributed control method for minimizing the operation cost in DC microgrid based on multiagent system. Each agent is autonomous and controls the local converter in a hierarchical way through droop control, voltage scheduling and collective decision making. The collect......In this paper we present a distributed control method for minimizing the operation cost in DC microgrid based on multiagent system. Each agent is autonomous and controls the local converter in a hierarchical way through droop control, voltage scheduling and collective decision making....... The collective decision for the whole system is made by proposed incremental cost consensus, and only nearest-neighbor communication is needed. The convergence characteristics of the consensus algorithm are analyzed considering different communication topologies and control parameters. Case studies verified...... the proposed method by comparing it without traditional methods. The robustness of system is tested under different communication latency and plug and play operation....

  17. [A technical suggestion for laboratory tests in cases of rape].

    Science.gov (United States)

    Fazio Pellacchio, M C; Celli, R

    1994-01-01

    The paper suggests completing the clinical tests carried out in cases of rape by collecting material not only from the fornix of the vagina but also from the cervical canal using cotton-wool buds, and examining any spermatozoa adhering to the cotton filaments by staining with Baecchi's method. Alternatively, the paper suggests carrying out these tests in anticipation of their possible use as forensic evidence if requested by the court.

  18. ESO adaptive optics facility progress and first laboratory test results

    Science.gov (United States)

    Arsenault, Robin; Madec, Pierre-Yves; Paufique, Jérome; La Penna, Paolo; Stroebele, Stefan; Vernet, Elise; Pirard, Jean-Francois; Hackenberg, Wolfgang; Kuntschner, Harald; Kolb, Johann; Muller, Nicolas; Garcia-Rissmann, Aurea; Le Louarn, Miska; Amico, Paola; Hubin, Norbert; Lizon, Jean-Louis; Ridings, Rob; Haguenauer, Pierre; Abad, Jose A.; Fischer, Gerhard; Heinz, Volker; Kiekebusch, Mario; Argomedo, Javier; Conzelmann, Ralf; Tordo, Sebastien; Donaldson, Rob; Soenke, Christian; Duhoux, Philippe; Fedrigo, Enrico; Delabre, Bernard; Jost, Andrea; Duchateau, Michel; Downing, Mark; Reyes Moreno, Javier; Manescau, Antonio; Bonaccini Calia, Domenico; Quattri, Marco; Dupuy, Christophe; Guidolin, Ivan M.; Comin, Mauro; Guzman, Ronald; Buzzoni, Bernard; Quentin, Jutta; Lewis, Steffan; Jolley, Paul; Kraus, Max; Pfrommer, Thomas; Biasi, Roberto; Gallieni, Daniele; Stuik, Remko; Kaenders, Wilhelm; Ernstberger, Bernhard; Friedenauer, Axel

    2014-07-01

    The Adaptive Optics Facility project is completing the integration of its systems at ESO Headquarters in Garching. The main test bench ASSIST and the 2nd Generation M2-Unit (hosting the Deformable Secondary Mirror) have been granted acceptance late 2012. The DSM has undergone a series of tests on ASSIST in 2013 which have validated its optical performance and launched the System Test Phase of the AOF. This has been followed by the performance evaluation of the GRAAL natural guide star mode on-axis and will continue in 2014 with its Ground Layer AO mode. The GALACSI module (for MUSE) Wide-Field-Mode (GLAO) and the more challenging Narrow-Field-Mode (LTAO) will then be tested. The AOF has also taken delivery of the second scientific thin shell mirror and the first 22 Watt Sodium laser Unit. We will report on the system tests status, the performances evaluated on the ASSIST bench and advancement of the 4Laser Guide Star Facility. We will also present the near future plans for commissioning on the telescope and some considerations on tools to ensure an efficient operation of the Facility in Paranal.

  19. Seed dressing pesticides on springtails in two ecotoxicological laboratory tests.

    Science.gov (United States)

    Alves, Paulo Roger L; Cardoso, Elke J B N; Martines, Alexandre M; Sousa, José Paulo; Pasini, Amarildo

    2014-07-01

    Terrestrial ecotoxicological tests are powerful tools for assessing the ecological risks that pesticides pose to soil invertebrates, but they are rarely used to evaluate seed dressing pesticides. This study investigated the effects of seed dressing pesticides on survival and reproduction of Folsomia candida (Collembola), using standardized ecotoxicological tests (after ISO guidelines with few adaptations for tropical conditions). Commercial formulations of five seed dressing pesticides were tested individually in Tropical Artificial Soil (TAS): the insecticides imidacloprid, fipronil, thiametoxam, and the fungicides captan and carboxin+thiram. Thiametoxam, captan, and carboxin+thiram were only lethal to F. candida at the highest concentration tested (1000mg of active ingredient kg(-1) of dry soil). Imidacloprid and fipronil were lethal at lower concentrations (100 and 10mg a.i. kg(-1) soil d.w, respectively), however, these concentrations were much higher than those predicted (PEC) for soil. Imidacloprid and fipronil were the most toxic pesticides in both tests, reducing significantly collembolan reproduction (EC20=0.02 and 0.12mga.i.kg(-1) soil d.w, respectively). Further studies under more realistic conditions are needed, since imidacloprid and fipronil reduced collembolan reproduction at concentrations below or close to their respective PECs.

  20. Accuracy in HIV Rapid Testing among Laboratory and Non-laboratory Personnel in Zambia: Observations from the National HIV Proficiency Testing System.

    Directory of Open Access Journals (Sweden)

    Sheila Mwangala

    Full Text Available Despite rapid task-shifting and scale-up of HIV testing services in high HIV prevalence countries, studies evaluating accuracy remain limited. This study aimed to assess overall accuracy level and factors associated with accuracy in HIV rapid testing in Zambia.Accuracy was investigated among rural and urban HIV testing sites participating in two annual national HIV proficiency testing (PT exercises conducted in 2009 (n = 282 sites and 2010 (n = 488 sites. Testers included lay counselors, nurses, laboratory personnel and others. PT panels of five dry tube specimens (DTS were issued to testing sites by the national reference laboratory (NRL. Site accuracy level was assessed by comparison of reported results to the expected results. Non-parametric rank tests and multiple linear regression models were used to assess variation in accuracy between PT cycles and between tester groups, and to examine factors associated with accuracy respectively.Overall accuracy level was 93.1% (95% CI: 91.2-94.9 in 2009 and 96.9% (95% CI: 96.1-97.8 in 2010. Differences in accuracy were seen between the tester groups in 2009 with laboratory personnel being more accurate than non-laboratory personnel, while in 2010 no differences were seen. In both PT exercises, lay counselors and nurses had more difficulties interpreting results, with more occurrences of false-negative, false-positive and indeterminate results. Having received the standard HIV rapid testing training and adherence to the national HIV testing algorithm were positively associated with accuracy.The study showed an improvement in tester group and overall accuracy from the first PT exercise to the next. Average number of incorrect test results per 1000 tests performed was reduced from 69 to 31. Further improvement is needed, however, and the national HIV proficiency testing system seems to be an important tool in this regard, which should be continued and needs to be urgently strengthened.

  1. A LABORATORY TEST FOR THE EXAMINATION OF ALACTIC RUNNING PERFORMANCE

    Directory of Open Access Journals (Sweden)

    Armin Kibele

    2005-12-01

    Full Text Available A new testing procedure is introduced to evaluate the alactic running performance in a 10s sprint task with near-maximal movement velocity. The test is performed on a motor-equipped treadmill with inverted polarity that increases mechanical resistance instead of driving the treadmill belt. As a result, a horizontal force has to be exerted against the treadmill surface in order to overcome the resistant force of the engine and to move the surface in a backward direction. For this task, subjects lean with their hands towards the front safety barrier of the treadmill railing with a slightly inclined body posture. The required skill resembles the pushing movement of bobsleigh pilots at the start of a race. Subjects are asked to overcome this mechanical resistance and to cover as much distance as possible within a time period of 10 seconds. Fifteen male students (age: 27.7 ± 4.1 years, body height: 1.82 ± 0.46 m, body mass: 78.3 ± 6.7 kg participated in a study. As the resistance force was set to 134 N, subjects ran 35.4 ± 2.6 m on the average corresponding to a mean running velocity of 3.52 ± 0.25 m·s-1. The validity of the new test was examined by statistical inference with various measures related to alactic performance including a metabolic equivalent to estimate alactic capacity (2892 ± 525 mL O2, an estimate for the oxygen debt (2662 ± 315 ml, the step test by Margaria to estimate alactic energy flow (1691 ± 171 W, and a test to measure the maximal strength in the leg extensor muscles (2304 ± 351 N. The statistical evaluation showed that the new test is in good agreement with the theoretical assumptions for alactic performance. Significant correlation coefficients were found between the test criteria and the measures for alactic capacity (r = 0.79, p < 0.01 as well as alactic power (r = 0.77, p < 0.01. The testing procedure is easy to administer and it is best suited to evaluate the alactic capacity for bobsleigh pilots as well as for

  2. Droop-free Distributed Control for AC Microgrids

    DEFF Research Database (Denmark)

    Nasirian, Vahidreza; Shafiee, Qobad; Guerrero, Josep M.

    2016-01-01

    guidelines are provided. Steady-state performance analysis shows that the proposed controller can accurately handle the global voltage regulation and proportional load sharing. An AC microgrid prototype is set up, where the controller performance, plug-and-play capability, and resiliency to the failure...... active power of each inverter with its neighbors’ and uses the difference to update the frequency and, accordingly, the phase angle of that inverter. The global dynamic model of the microgrid, including distribution grid, regulator modules, and the communication network, is derived, and controller design......A cooperative distributed secondary/primary control paradigm for AC microgrids is proposed. This solution replaces the centralized secondary control and the primary-level droop mechanism of each inverter with three separate regulators: voltage, reactive power, and active power regulators. A sparse...

  3. Microgrid Controllers : Expanding Their Role and Evaluating Their Performance

    Energy Technology Data Exchange (ETDEWEB)

    Maitra, Arindam; Pratt, Annabelle; Hubert, Tanguy; Wang, Dean; Prabakar, Kumaraguru; Handa, Rachna; Baggu, Murali; McGranaghan, Mark

    2017-07-01

    Microgrids have long been deployed to provide power to customers in remote areas as well as critical industrial and military loads. Today, they are also being proposed as grid-interactive solutions for energy-resilient communities. Such microgrids will spend most of the time operating while synchronized with the surrounding utility grid but will also be capable of separating during contingency periods due to storms or temporary disturbances such as local grid faults. Properly designed and grid-integrated microgrids can provide the flexibility, reliability, and resiliency needs of both the future grid and critical customers. These systems can be an integral part of future power system designs that optimize investments to achieve operational goals, improved reliability, and diversification of energy sources.

  4. Hybrid Shipboard Microgrids: System Architectures and Energy Management Aspects

    DEFF Research Database (Denmark)

    Othman @ Marzuki, Muzaidi Bin; Anvari-Moghaddam, Amjad; Guerrero, Josep M.

    2017-01-01

    such as renewables (e.g., solar PV, wind power) and conventionals (e.g., diesel engines) as well as energy storage systems (ESSs) such as batteries, fuel cells and flywheels. To optimally manage different energy sources in a shipboard microgrid while meeting different technical/environmental constraints......Strict regulation on emissions of air pollutants imposed by the maritime authorities has led to the introduction of hybrid microgrids to the shipboard power systems (SPSs) which acts toward energy efficient ships with less pollution. A hybrid energy system can include different means of generation......, it is necessary to set up an energy management system. This paper provides an overview of hybrid shipboard microgrids and discusses different methods of power and energy management in such systems which are essential for control, monitoring and optimizing the overall system performance in various mission profiles....

  5. Distributed Generation Investment by a Microgrid UnderUncertainty

    Energy Technology Data Exchange (ETDEWEB)

    Siddiqui, Afzal; Marnay, Chris

    2006-06-16

    This paper examines a California-based microgrid s decision to invest in a distributed generation (DG) unit that operates on natural gas. While the long-term natural gas generation cost is stochastic, we initially assume that the microgrid may purchase electricity at a fixed retail rate from its utility. Using the real options approach, we find natural gas generating cost thresholds that trigger DG investment. Furthermore, the consideration of operational flexibility by the microgrid accelerates DG investment, while the option to disconnect entirely from the utility is not attractive. By allowing the electricity price to be stochastic, we next determine an investment threshold boundary and find that high electricity price volatility relative to that of natural gas generating cost delays investment while simultaneously increasing the value of the investment. We conclude by using this result to find the implicit option value of the DG unit.

  6. Single Phase Bidirectional PWM Converter for Microgrid System

    Directory of Open Access Journals (Sweden)

    C.Kalavalli

    2013-06-01

    Full Text Available Smart grid is a newly flourishing research area because of its viable applications and expected to address the drawback of existing grid. Microgrids are the part of the Smart grid and they are designed to supply electricity for a small community such as residential areas, universities or industrial sites. Power electronics plays a vital role for connecting the renewable energy sources to Microgrid system. This paper deals the Microgrid connected single phase Bidirectional PWM converter which operates in Rectification and Inverting mode. This converter helps to connect renewable energy sources to loads as well as excess power are given to power grid. Double Loop PID control technique is used for controlling the converter for both modes. The designed Converter is simulated in MATLAB/Simulink software and results are verified using the Hardware.

  7. Hierarchical energy management mechanisms for an electricity market with microgrids

    Directory of Open Access Journals (Sweden)

    Hong-Tzer Yang

    2014-08-01

    Full Text Available This study addresses a micro-grid electricity market (MGEM with day-ahead (DA and real-time market mechanisms integrated. The bidding mechanisms for the market are described in this study, considering the generation cost of different distributed energy resources (DERs, like distributed generator, energy storage system and demand response. Including load and renewable generation forecasting systems and a fuzzy decision supporting system, a hierarchical micro-grid energy management system (MG-EMS is then proposed to ensure the benefits of involved micro-grid central controller, DER owners and customers. To verify the feasibility of the proposed system, the whole-year historical pricing and load data for New England independent system operator are employed. The numerical results show that the proposed MG-EMS is promising and effective for the operations of MGEM.

  8. Optimal Power Flow in Microgrids with Energy Storage

    DEFF Research Database (Denmark)

    Levron, Yoash; Guerrero, Josep M.; Beck, Yuval

    2013-01-01

    , these works assume flat, highly simplified network models, which overlook the physical connectivity. This work proposes an optimal power flow solution that considers the entire system: the storage device limits, voltages limits, currents limits, and power limits. The power network may be arbitrarily complex......Energy storage may improve power management in microgrids that include renewable energy sources. The storage devices match energy generation to consumption, facilitating a smooth and robust energy balance within the microgrid. This paper addresses the optimal control of the microgrid’s energy...... storage devices. Stored energy is controlled to balance power generation of renewable sources to optimize overall power consumption at the microgrid point of common coupling. Recent works emphasize constraints imposed by the storage device itself, such as limited capacity and internal losses. However...

  9. Laboratory Jet Erosion Tests on the Lower American River Soil Samples, Sacramento, CA- Phase 2

    Science.gov (United States)

    2017-05-01

    ER D C/ G SL T R- 17 -8 Laboratory Jet Erosion Tests on the Lower American River Soil Samples, Sacramento, CA – Phase 2 G eo te ch ni...Jet Erosion Tests on the Lower American River Soil Samples, Sacramento, CA – Phase 2 Johannes L. Wibowo and Bryant A. Robbins Geotechnical and...laboratory Jet Erosion Tests performed on Plexiglas tube samples obtained from the Lower American River (LAR) between River Mile (RM) 6.0 and RM

  10. Cognitive Laboratory Experiences : On Pre-testing Computerised Questionnaires

    NARCIS (Netherlands)

    Snijkers, G.J.M.E.

    2002-01-01

    In the literature on questionnaire design and survey methodology, pre-testing is mentioned as a way to evaluate questionnaires (i.e. investigate whether they work as intended) and control for measurement errors (i.e. assess data quality). As the American Statistical Association puts it (ASA, 1999, p

  11. Modeling and Testing of EVs - Preliminary Study and Laboratory Development

    DEFF Research Database (Denmark)

    Yang, Guang-Ya; Marra, Francesco; Nielsen, Arne Hejde;

    2010-01-01

    Electric vehicles (EVs) are expected to play a key role in the future energy management system to stabilize both supply and consumption with the presence of high penetration of renewable generation. A reasonably accurate model of battery is a key element for the study of EVs behavior and the grid...... tests, followed by the suggestions towards a feasible battery model for further studies....

  12. Laboratory longitudinal diffusion tests: 2. Parameter estimation by inverse analysis

    Science.gov (United States)

    Takeda, M.; Zhang, M.; Nakajima, H.; Hiratsuka, T.

    2008-04-01

    This study focuses on the verification of test interpretations for different state analyses of diffusion experiments. Part 1 of this study identified that steady, quasi-steady and equilibrium state analyses for the through- and in-diffusion tests with solution reservoirs are generally feasible where the tracer is not highly sorptive. In Part 2 we investigate parameter identifiability in transient-state analysis of reservoir concentration variation using a numerical approach. For increased generality, the analytical models, objective functions and Jacobian matrix necessary for inverse analysis of transient-state data are reformulated using unified dimensionless parameters. In these dimensionless forms, the number of unknown parameters is reduced and a single dimensionless parameter represents the sorption property. The dimensionless objective functions are evaluated for individual test methods and parameter identifiability is discussed in relation to the sorption property. The effects of multiple minima and measurement error on parameter identifiability are also investigated. The main findings are that inverse problems for inlet and outlet reservoir concentration analyses are generally unstable and well-posed, respectively. Where the tracer is sorptive, the inverse problem for the inlet reservoir concentration analysis may have multiple minima. When insufficient measurement data is collected, multiple solutions may result and this should be taken into consideration when inversely analyzing data including that of inlet reservoir concentration. Verification of test interpretation by cross-checking different state analyses is feasible where the tracer is not highly sorptive. In an actual experiment, test interpretation validity is demonstrated through consistency between theory and practice for different state analyses.

  13. Laboratory and clinical evaluation of on-site urine drug testing.

    Science.gov (United States)

    Beck, Olof; Carlsson, Sten; Tusic, Marinela; Olsson, Robert; Franzen, Lisa; Hulten, Peter

    2014-11-01

    Products for on-site urine drug testing offer the possibility to perform screening for drugs of abuse directly at the point-of-care. This is a well-established routine in emergency and dependency clinics but further evaluation of performance is needed due to inherent limitations with the available products. Urine drug testing by an on-site product was compared with routine laboratory methods. First, on-site testing was performed at the laboratory in addition to the routine method. Second, the on-site testing was performed at a dependency clinic and urine samples were subsequently sent to the laboratory for additional analytical investigation. The on-site testing products did not perform with assigned cut-off levels. The subjective reading between the presence of a spot (i.e. negative test result) being present or no spot (positive result) was difficult in 3.2% of the cases, and occurred for all parameters. The tests performed more accurately in drug negative samples (specificity 96%) but less accurately for detecting positives (sensitivity 79%). Of all incorrect results by the on-site test the proportion of false negatives was 42%. The overall agreement between on-site and laboratory testing was 95% in the laboratory study and 98% in the clinical study. Although a high degree of agreement was observed between on-site and routine laboratory urine drug testing, the performance of on-site testing was not acceptable due to significant number of false negative results. The limited sensitivity of on-site testing compared to laboratory testing reduces the applicability of these tests.

  14. Argonne National Laboratory`s photo-oxidation organic mixed waste treatment system - installation and startup testing

    Energy Technology Data Exchange (ETDEWEB)

    Shearer, T.L.; Nelson, R.A.; Torres, T.; Conner, C.; Wygmans, D.

    1997-09-01

    This paper describes the installation and startup testing of the Argonne National Laboratory (ANL-E) Photo-Oxidation Organic Mixed Waste Treatment System. This system will treat organic mixed (i.e., radioactive and hazardous) waste by oxidizing the organics to carbon dioxide and inorganic salts in an aqueous media. The residue will be treated in the existing radwaste evaporators. The system is installed in the Waste Management Facility at the ANL-E site in Argonne, Illinois. 1 fig.

  15. Standard Test Method for Laboratory Aging of Sandwich Constructions

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1999-01-01

    1.1 This test method covers the determination of the resistance of sandwich panels to severe exposure conditions as measured by the change in selected properties of the material after exposure. The exposure cycle to which the specimen is subjected is an arbitrary test having no correlation with natural weathering conditions. 1.2 The values stated in SI units are to be regarded as the standard. The inch-pound units given may be approximate. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  16. The Wastewater Treatment Test Facility at Oak Ridge National Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Richardson, S.A.; Kent, T.E.; Taylor, P.A. [Oak Ridge National Lab., TN (United States)

    1995-12-01

    The Wastewater Treatment Test Facility (WTTF) contains 0.5 L/min test systems which provide a wide range of physical and chemical separation unit operations. The facility is a modified 48 foot trailer which contains all the unit operations of the ORNL`s Process Waste Treatment Plant and Nonradiological Wastewater Treatment Plant including chemical precipitation, clarification, filtration, ion-exchange, air stripping, activated carbon adsorption, and zeolite system. This facility has been used to assess treatability of potential new wastewaters containing mixed radioactive, hazardous organic, and heavy metal compounds. With the ability to simulate both present and future ORNL wastewater treatment systems, the WTTF has fast become a valuable tool in solving wastewater treatment problems at the Oak Ridge reservation.

  17. Lysosomal storage disorders: Molecular basis and laboratory testing

    Directory of Open Access Journals (Sweden)

    Filocamo Mirella

    2011-03-01

    Full Text Available Abstract Lysosomal storage disorders (LSDs are a large group of more than 50 different inherited metabolic diseases which, in the great majority of cases, result from the defective function of specific lysosomal enzymes and, in cases, of non-enzymatic lysosomal proteins or non-lysosomal proteins involved in lysosomal biogenesis. The progressive lysosomal accumulation of undegraded metabolites results in generalised cell and tissue dysfunction, and, therefore, multi-systemic pathology. Storage may begin during early embryonic development, and the clinical presentation for LSDs can vary from an early and severe phenotype to late-onset mild disease. The diagnosis of most LSDs--after accurate clinical/paraclinical evaluation, including the analysis of some urinary metabolites--is based mainly on the detection of a specific enzymatic deficiency. In these cases, molecular genetic testing (MGT can refine the enzymatic diagnosis. Once the genotype of an individual LSD patient has been ascertained, genetic counselling should include prediction of the possible phenotype and the identification of carriers in the family at risk. MGT is essential for the identification of genetic disorders resulting from non-enzymatic lysosomal protein defects and is complementary to biochemical genetic testing (BGT in complex situations, such as in cases of enzymatic pseudodeficiencies. Prenatal diagnosis is performed on the most appropriate samples, which include fresh or cultured chorionic villus sampling or cultured amniotic fluid. The choice of the test--enzymatic and/or molecular--is based on the characteristics of the defect to be investigated. For prenatal MGT, the genotype of the family index case must be known. The availability of both tests, enzymatic and molecular, enormously increases the reliability of the entire prenatal diagnostic procedure. To conclude, BGT and MGT are mostly complementary for post- and prenatal diagnosis of LSDs. Whenever genotype

  18. An audit of serological tests carried out at clinical laboratory of Ayub Teaching Hospital, Abbottabad.

    Science.gov (United States)

    Ally, Sirajuddin Hassan; Ahmed, Ayesha; Hanif, Ruhila

    2005-01-01

    Clinical audit is an important tool for reviewing and improving the quality of service in clinical laboratories. Here we present an audit of total serology test requests and the frequency of positive tests out of these in a calendar year. This is an audit of serology tests carried out at Microbiology section of Clinical Laboratory of Ayub Teaching Hospital, Abbottabad. We counted all the serology test requests for the year 2004. These tests requests were grouped month wise. The frequency of positive tests out of the total test requests were calculated. The tests included Widal, Toxoplasma, Brucella, Anti DNA, Anti Nuclear factor (ANF), Rheumatoid Arthritis Factor (RAF), HIV, HBsAg, HCV, Intra Chromatographic Technique for tuberculosis (ICT-TB), Purified Protein Derivative (PPD), Venereal Disease Research Laboratory (VDRL) test, Anti-Streptolysin-O-test (ASOT) and pregnancy test. This audit gives a clear idea of trends of test requests in our hospital. It reflects accuracy of clinicians' judgment in some tests and failure in others, prevalence of different diseases, seasonal variation in number of test requests for some tests and impact of awareness campaigns on attitude of clinicians towards certain diseases. This will help us in planning our laboratory requirements to improve quality.

  19. Development of a novel SCADA system for laboratory testing.

    Science.gov (United States)

    Patel, M; Cole, G R; Pryor, T L; Wilmot, N A

    2004-07-01

    This document summarizes the supervisory control and data acquisition (SCADA) system that allows communication with, and controlling the output of, various I/O devices in the renewable energy systems and components test facility RESLab. This SCADA system differs from traditional SCADA systems in that it supports a continuously changing operating environment depending on the test to be performed. The SCADA System is based on the concept of having one Master I/O Server and multiple client computer systems. This paper describes the main features and advantages of this dynamic SCADA system, the connections of various field devices to the master I/O server, the device servers, and numerous software features used in the system. The system is based on the graphical programming language "LabVIEW" and its "Datalogging and Supervisory Control" (DSC) module. The DSC module supports a real-time database called the "tag engine," which performs the I/O operations with all field devices attached to the master I/O server and communications with the other tag engines running on the client computers connected via a local area network. Generic and detailed communication block diagrams illustrating the hierarchical structure of this SCADA system are presented. The flow diagram outlining a complete test performed using this system in one of its standard configurations is described.

  20. [Approval of ISO/IEC 17025 and quality control of laboratory testing].

    Science.gov (United States)

    Yamamoto, Shigeki; Asakura, Hiroshi; Machii, Kenji; Igimi, Shizunobu

    2010-01-01

    First section of Division of Biomedical Food Research, National Institute of Health Sciences (NIHS) was approved by ISO/IEC 17025 as a laboratory having an appropriate laboratory testing technique. NIHS is the first national laboratory approved by ISO/IEC 17025. NIHS has also been accepted the appropriate technique and facility for the BSL3 level pathogens by ISO/IEC 17025. NIHS is necessary to take an external audit almost every year. This approval is renewed every 4 years.

  1. Hydraulic laboratory testing of Sontek-IQ Plus

    Science.gov (United States)

    Fulford, Janice M.; Kimball, Scott

    2015-11-10

    The SonTek-IQ Plus (IQ Plus) is a bottom-mounted Doppler instrument used for the measurement of water depth and velocity. Evaluation testing of the IQ Plus was performed to assess the accuracy of water depth, discharge, and velocity measurements. The IQ Plus met the manufacturer’s specifications and the U.S. Geological Survey (USGS) standard for depth accuracy measurement when the unit was installed, according to the manufacturer’s instructions, at 0 degrees pitch and roll. However, because of the limited depth testing conducted, the depth measurement is not recommended as a primary stage measurement. The IQ Plus was tested in a large indoor tilting flume in a 5-foot (ft) wide, approximately 2.3-ft deep section with mean velocities of 0.5, 1, 2, and 3 ft per second. Four IQ Plus instruments using firmware 1.52 tested for water-discharge accuracy using SonTek’s “theoretical” discharge method had a negative bias of -2.4 to -11.6 percent when compared with discharge measured with a SonTek FlowTracker and the midsection discharge method. The IQ Pluses with firmware 1.52 did not meet the manufacturer’s specification of +/-1 percent for measuring velocity. Three IQ Pluses using firmware 1.60 and SonTek’s “theoretical” method had a difference of -1.6 to -7.9 percent when compared with discharge measured with a SonTek FlowTracker and the midsection method. Mean-velocity measurements with firmware 1.60 met the manufacturer’s specification and Price Type AA meter accuracy requirements when compared with FlowTracker measurements. Because of the instrument’s velocity accuracy, the SonTek-IQ Plus with firmware 1.60 is considered acceptable for use as an index velocity instrument for the USGS. The discharge computed by the SonTek-IQ Plus during the tests had a substantial negative bias and will not be as accurate as a discharge computed with the index velocity method. The USGS does not recommend the use of undocumented computation methods, such as Son

  2. Canadian Public Health Laboratory Network laboratory Guidelines for the Use of Serological Tests (excluding point-of-care tests for the Diagnosis of Syphilis in Canada

    Directory of Open Access Journals (Sweden)

    Paul N Levett

    2015-01-01

    Full Text Available Syphilis, caused by the bacterium Treponema pallidum subsp. pallidum, is an infection recognized since antiquity. It was first reported at the end of the 15th century in Europe. Infections may be sexually transmitted as well as spread from an infected mother to her fetus or through blood transfusions. The laboratory diagnosis of syphilis infection is complex. Because this organism cannot be cultured, serology is used as the principal diagnostic method. Some of the issues related to serological diagnoses are that antibodies take time to appear after infection, and serology screening tests require several secondary confirmatory tests that can produce complex results needing interpretation by experts in the field. Traditionally, syphilis screening was performed using either rapid plasma reagin or Venereal Disease Research Laboratory tests, and confirmed by treponemal tests such as MHA-TP, TPPA or FTA-Abs. Currently, that trend is reversed, ie, most of the laboratories in Canada now screen for syphilis using treponemal enzyme immunoassays and confirm the status of infection using rapid plasma reagin or Venereal Disease Research Laboratory tests; this approach is often referred to as the reverse algorithm. This chapter reviews guidelines for specimen types and sample collection, treponemal and non-treponemal tests utilized in Canada, the current status of serological tests for syphilis in Canada, the complexity of serological diagnosis of syphilis infection and serological testing algorithms. Both traditional and reverse sequence algorithms are recommended and the algorithm used should be based on a combination of local disease epidemiology, test volumes, performance of the proposed assays and available resources.

  3. Canadian Public Health Laboratory Network laboratory guidelines for the use of serological tests (excluding point-of-care tests) for the diagnosis of syphilis in Canada.

    Science.gov (United States)

    Levett, Paul N; Fonseca, Kevin; Tsang, Raymond Sw; Kadkhoda, Kamran; Serhir, Bouchra; Radons, Sandra M; Morshed, Muhammad

    2015-01-01

    Syphilis, caused by the bacterium Treponema pallidum subsp. pallidum, is an infection recognized since antiquity. It was first reported at the end of the 15th century in Europe. Infections may be sexually transmitted as well as spread from an infected mother to her fetus or through blood transfusions. The laboratory diagnosis of syphilis infection is complex. Because this organism cannot be cultured, serology is used as the principal diagnostic method. Some of the issues related to serological diagnoses are that antibodies take time to appear after infection, and serology screening tests require several secondary confirmatory tests that can produce complex results needing interpretation by experts in the field. Traditionally, syphilis screening was performed using either rapid plasma reagin or Venereal Disease Research Laboratory tests, and confirmed by treponemal tests such as MHA-TP, TPPA or FTA-Abs. Currently, that trend is reversed, ie, most of the laboratories in Canada now screen for syphilis using treponemal enzyme immunoassays and confirm the status of infection using rapid plasma reagin or Venereal Disease Research Laboratory tests; this approach is often referred to as the reverse algorithm. This chapter reviews guidelines for specimen types and sample collection, treponemal and non-treponemal tests utilized in Canada, the current status of serological tests for syphilis in Canada, the complexity of serological diagnosis of syphilis infection and serological testing algorithms. Both traditional and reverse sequence algorithms are recommended and the algorithm used should be based on a combination of local disease epidemiology, test volumes, performance of the proposed assays and available resources.

  4. [Assessment of the quality of laboratory diagnosis of intestinal parasitic diseases by the laboratories participating in the Federal System of External Quality Assessment of Clinical Laboratory Testing].

    Science.gov (United States)

    Malakhov, V N; Dovgalev, A S; Astanina, S Iu; Serdiuk, A P

    2014-01-01

    In 2010-2013, the quality of microscopic detection of the causative agents ofparasitic diseases in the feces has been assessed by the specialists of the laboratories of the therapeutic-and-prophylactic institutions (TPIs) and Hygiene and Epidemiology Centers, Russian Inspectorate for the Protection of Consumer Rights and Human Welfare, which are participants of the Federal System of External Quality Assessment of Clinical Laboratory Testing. Thirty-two specimens containing 16 species of human helminths and 4 species of enteric protozoa in different combinations were examined. The findings suggest that the quality of microscopic detection of the causative agents of parasitic diseases is low in the laboratories of health care facilities and that the specialists of the laboratories of TPIs and Hygiene and Epidemiology Centers, Russian Inspectorate for the Protection of Consumer Rights and Human Welfare, do not not possess the knowledge and skills necessary to make a laboratory diagnosis of helminths and enteric protozoa. The average detection rates of helminths and protozoa were at a level of 64 and 36%, respectively. The correct results showed that the proportion of helminths and protozoa were 94.5 and 5.5%, respectively. According to the biological and epidemiological classification of helminths, there were higher detection rates for contact group parasites (Enterobius vermicularis and Hymenolepis nana) and geohelminths (Ascaris, Trichuris trichiura, and others). Biohelminths (Opisthorchis, tapeworms, and others) Were detectable slightly worse.

  5. Autonomous Active and Reactive Power Distribution Strategy in Islanded Microgrids

    DEFF Research Database (Denmark)

    Wu, Dan; Tang, Fen; Guerrero, Josep M.;

    2014-01-01

    This paper proposes an autonomous active and reactive power distribution strategy that can be applied directly on current control mode (CCM) inverters, being compatible as well with conventional droop-controlled voltage control mode (VCM) converters. In a microgrid, since renewable energy sources...... in a distributed way. Real-time hardware-in-the-loop results are presented to verify the proposed control strategy.......This paper proposes an autonomous active and reactive power distribution strategy that can be applied directly on current control mode (CCM) inverters, being compatible as well with conventional droop-controlled voltage control mode (VCM) converters. In a microgrid, since renewable energy sources...

  6. Hierarchical Control for Multiple DC-Microgrids Clusters

    DEFF Research Database (Denmark)

    Shafiee, Qobad; Dragicevic, Tomislav; Vasquez, Juan Carlos

    2014-01-01

    DC microgrids (MGs) have gained research interest during the recent years because of many potential advantages as compared to the ac system. To ensure reliable operation of a low-voltage dc MG as well as its intelligent operation with the other DC MGs, a hierarchical control is proposed in this p......DC microgrids (MGs) have gained research interest during the recent years because of many potential advantages as compared to the ac system. To ensure reliable operation of a low-voltage dc MG as well as its intelligent operation with the other DC MGs, a hierarchical control is proposed...

  7. Online algorithms for optimal energy distribution in microgrids

    CERN Document Server

    Wang, Yu; Nelms, R Mark

    2015-01-01

    Presenting an optimal energy distribution strategy for microgrids in a smart grid environment, and featuring a detailed analysis of the mathematical techniques of convex optimization and online algorithms, this book provides readers with essential content on how to achieve multi-objective optimization that takes into consideration power subscribers, energy providers and grid smoothing in microgrids. Featuring detailed theoretical proofs and simulation results that demonstrate and evaluate the correctness and effectiveness of the algorithm, this text explains step-by-step how the problem can b

  8. Power flow analysis for DC voltage droop controlled DC microgrids

    DEFF Research Database (Denmark)

    Li, Chendan; Chaudhary, Sanjay; Dragicevic, Tomislav

    2014-01-01

    This paper proposes a new algorithm for power flow analysis in droop controlled DC microgrids. By considering the droop control in the power flow analysis for the DC microgrid, when compared with traditional methods, more accurate analysis results can be obtained. The algorithm verification...... is carried out by comparing the calculation results with detailed time domain simulation results. With the droop parameters as variables in the power flow analysis, their effects on power sharing and secondary voltage regulation can now be analytically studied, and specialized optimization in the upper level...... control can also be made accordingly. Case studies on power sharing and secondary voltage regulation are carried out using proposed power flow analysis....

  9. Hierarchical Control Scheme for Voltage Unbalance Compensation in Islanded Microgrids

    DEFF Research Database (Denmark)

    Savaghebi, Mehdi; Guerrero, Josep M.; Jalilian, Alireza;

    2011-01-01

    active and reactive power controllers, virtual impedance loop and voltage and current controllers. The secondary level is designed to compensate the voltage unbalance at the load bus (LB) of the islanded microgrid. Also, restoration of LB voltage amplitude and microgrid frequency to the rated values...... is considered in the secondary level. These functions are achieved by proper control of distributed generators (DGs) interface converters. The presented simulation results show the effectiveness of the proposed control structure in compensating the voltage unbalance and restoring the voltage amplitude...

  10. Design and Scheduling of Microgrids using Benders Decomposition

    Energy Technology Data Exchange (ETDEWEB)

    Nagarajan, Adarsh; Ayyanar, Raja

    2016-11-21

    The distribution feeder laterals in a distribution feeder with relatively high PV generation as compared to the load can be operated as microgrids to achieve reliability, power quality and economic benefits. However, renewable resources are intermittent and stochastic in nature. A novel approach for sizing and scheduling an energy storage system and microturbine for reliable operation of microgrids is proposed. The size and schedule of an energy storage system and microturbine are determined using Benders' decomposition, considering PV generation as a stochastic resource.

  11. Adaptive Overcurrent Protection for Microgrids in Extensive Distribution Systems

    DEFF Research Database (Denmark)

    Lin, Hengwei; Guerrero, Josep M.; Jia, Chenxi

    2016-01-01

    is treated as a linear programming problem for the different operation states. In the control center, an artificial neural network (ANN) model is trained with real-time measurements to identify the states whether there is a fault on the line segment. Fault location is estimated further with the same......Microgrid is regarded as a new form to integrate the increasing penetration of distributed generation units (DGs) in the extensive distribution systems. This paper proposes an adaptive overcurrent protection strategy for a microgrid network. The protection coordination of the overcurrent relays...

  12. Secondary control for voltage unbalance compensation in an islanded microgrid

    DEFF Research Database (Denmark)

    Savaghebi, Mehdi; Guerrero, Josep M.; Jalilian, Alireza

    2011-01-01

    In this paper, the concept of secondary control is applied for voltage unbalance compensation in an islanded microgrid. The aim of the proposed control approach is to enhance the voltage quality at the point of common coupling (PCC). Unbalance compensation is achieved by proper control of distrib......In this paper, the concept of secondary control is applied for voltage unbalance compensation in an islanded microgrid. The aim of the proposed control approach is to enhance the voltage quality at the point of common coupling (PCC). Unbalance compensation is achieved by proper control...

  13. Microgrid Reactive and Harmonic Power Sharing Using Enhanced Virtual Impedance

    DEFF Research Database (Denmark)

    He, Jinwei; Wei Li, Yun; Guerrero, Josep M.

    2013-01-01

    To address the load sharing problem in islanding microgrids, this paper proposes an improved approach which regulates the distributed generation (DG) unit interfacing virtual impedance at fundamental and selected harmonic frequencies. In contrast to the conventional virtual impedance control where...... feeder impedances can be properly compensated, resulting in accurate reactive and harmonic power sharing at the same time. In addition, this paper shows that the microgrid PCC harmonic voltages can be mitigated by reducing the magnitude of DG unit equivalent harmonic impedance. Finally, an improved...

  14. Active Power Regulation based on Droop for AC Microgrid

    DEFF Research Database (Denmark)

    Li, Chendan; Coelho, Ernane A. A.; Firoozabadi, Mehdi Savaghebi

    2015-01-01

    In this paper, two different control strategies are proposed to address the active power regulation issue in AC microgrids. The principle of power regulation in the droop controller is firstly introduced. Frequency scheduling and droop gain scheduling on top of droop control is proposed to succes......In this paper, two different control strategies are proposed to address the active power regulation issue in AC microgrids. The principle of power regulation in the droop controller is firstly introduced. Frequency scheduling and droop gain scheduling on top of droop control is proposed...

  15. Control Strategy for Microgrid Inverter under Unbalanced Grid Voltage Conditions

    DEFF Research Database (Denmark)

    Guo, Xiaoqiang; Liu, Wenzhao; Zhang, X.

    2014-01-01

    This paper presents the theoretical analysis of the inherent reason of current harmonic and power oscillation phenomena in case of operating the microgrid inverter under unbalanced grid voltage conditions. In order to flexibly control the current harmonic and power oscillation, a new stationary...... frame control strategy is proposed. It has a simple control structure due to no need of a phase-locked loop and voltage/current positive/negative sequence extraction calculation. The coordinate control of power and current quality is achieved, which enhances the operation performance of microgrid...

  16. Point of care testing: diagnosis outside the virology laboratory.

    Science.gov (United States)

    Blyth, Christopher C; Booy, Robert; Dwyer, Dominic E

    2011-01-01

    Numerous point-of-care tests (POCTs) are available to diagnose viral infections in both hospital and community settings. The ideal POCT is rapid, sensitive, specific, and simple to perform. This chapter will describe the benefits of POCTs, factors that can influence the accuracy of POCTs and highlight some limitations of POCT strategies. The sensitivity, specificity, and turn-around time of available POCTs are included for common conditions including respiratory viral infections (e.g. influenza, RSV) and blood-borne viral infections (e.g. HIV).

  17. Vehicle Testing and Integration Facility; NREL (National Renewable Energy Laboratory)

    Energy Technology Data Exchange (ETDEWEB)

    None

    2015-03-02

    Engineers at the National Renewable Energy Laboratory’s (NREL’s) Vehicle Testing and Integration Facility (VTIF) are developing strategies to address two separate but equally crucial areas of research: meeting the demands of electric vehicle (EV) grid integration and minimizing fuel consumption related to vehicle climate control. Dedicated to renewable and energy-efficient solutions, the VTIF showcases technologies and systems designed to increase the viability of sustainably powered vehicles. NREL researchers instrument every class of on-road vehicle, conduct hardware and software validation for EV components and accessories, and develop analysis tools and technology for the Department of Energy, other government agencies, and industry partners.

  18. Modeling and Testing of EVs - Preliminary Study and Laboratory Development

    DEFF Research Database (Denmark)

    Yang, Guang-Ya; Marra, Francesco; Nielsen, Arne Hejde

    2010-01-01

    impact at different geographical areas, as well as driving and charging patterns. Electric circuit model is deployed in this work to represent the electrical properties of a lithium-ion battery. This paper reports the preliminary modeling and validation work based on manufacturer data sheet and realistic......Electric vehicles (EVs) are expected to play a key role in the future energy management system to stabilize both supply and consumption with the presence of high penetration of renewable generation. A reasonably accurate model of battery is a key element for the study of EVs behavior and the grid...... tests, followed by the suggestions towards a feasible battery model for further studies....

  19. How to test NISP instrument for EUCLID mission in laboratory

    DEFF Research Database (Denmark)

    Costille, A.; Carle, Michael; Fabron, Christophe;

    2016-01-01

    . To achieve these tests campaign, a global Ground Support Equipment (GSE) called the Verification Ground System (VGS) has to be developed. It will be a complex set of GSE integrated in ERIOS chamber made of: a telescope simulator to simulate the EUCLID telescope and to inject light into NISP, a thermal...... will present the preliminary design and concepts of the VGS and we will show the main difficulties we have to deal with: design of thermal environment at 80K with 4mK stability, the development of a metrology system in vacuum, knowledge of the focus position within 150μm in cold, etc. The main objectives...

  20. Analytical Chemistry Laboratory (ACL) procedure compendium. Volume 6, Physical testing

    Energy Technology Data Exchange (ETDEWEB)

    1993-08-01

    This volume contains the interim change notice for physical testing. Covered are: properties of solutions, slurries, and sludges; rheological measurement with cone/plate viscometer; % solids determination; particle size distribution by laser scanning; penetration resistance of radioactive waste; operation of differential scanning calorimeter, thermogravimetric analyzer, and high temperature DTA and DSC; sodium rod for sodium bonded fuel; filling SP-100 fuel capsules; sodium filling of BEATRIX-II type capsules; removal of alkali metals with ammonia; specific gravity of highly radioactive solutions; bulk density of radioactive granular solids; purification of Li by hot gettering/filtration; and Li filling of MOTA capsules.

  1. NREL Highlight: Truck Platooning Testing; NREL (National Renewable Energy Laboratory)

    Energy Technology Data Exchange (ETDEWEB)

    None

    2015-05-21

    NREL's fleet test and evaluation team assesses the fuel savings potential of semi-automated truck platooning of line-haul sleeper cabs with modern aerodynamics. Platooning reduces aerodynamic drag by grouping vehicles together and safely decreasing the distance between them via electronic coupling, which allows multiple vehicles to accelerate or brake simultaneously. In 2014, the team conducted track testing of three SmartWay tractor - two platooned tractors and one control tractor—at varying steady-state speeds, following distances, and gross vehicle weights. While platooning improved fuel economy at all speeds, travel at 55 mph resulted in the best overall miles per gallon. The lead truck demonstrated fuel savings up to 5.3% while the trailing truck saved up to 9.7%. A number of conditions impact the savings attainable, including ambient temperature, distance between lead and trailing truck, and payload weight. Future studies may look at ways to optimize system fuel efficiency and emissions reductions.

  2. Laboratory testing of novel sealant for leaky wells

    Energy Technology Data Exchange (ETDEWEB)

    Bibic, O. [EnCana Corp., Calgary, AB (Canada); Polikar, M. [Alberta Univ., Edmonton, AB (Canada); Boyd, J. [Seal-MastR Systems Ltd., Clagary, AB (Canada)

    2006-07-01

    Abandoned gas wells in western Canada often leak gas to the surface. An experimental study was conducted in order to determine the possibility of using an asphalt-in-water emulsion as sealant for abandoned leaky wells. This is considered a more efficient and cost-effective method to the conventional cement grout barrier. The study objective was to test this new sealant technology proposed by Seal-MastR and to examine the effect of those parameters affecting the placement and fixing of an emulsion in the near well bore matrix, thereby hindering the flow of water or gas. Two types of experiments were conducted as part of this study. The mechanism of the emulsion penetration into the porous matrix was studied making observations of the process in a transparent core holder. The process was investigated using a steel core holder that allows injection of the emulsion at actual well pressures. It was concluded that the asphalt-in-water emulsion technology can be used with success for sealing abandoned gas-leaking wells or water-producing formations. The study also proposed recommendations for field application and suggested areas for further research to improve the process, such as finding the optimum concentration for the surfactant solution pre-flush that would yield the highest penetration, and testing the emulsion in oil-wet or partially oil-wet formation. 4 refs., 3 tabs., 19 figs.

  3. The application of data from proficiency testing to laboratory accreditation according to ISO 17025

    DEFF Research Database (Denmark)

    Heydorn, Kaj

    2008-01-01

    Current methods of testing laboratories for their proficiency in reporting correct measurement results are liable to substantial errors of the 2nd kind. This means that laboratories with deflated uncertainties are accepted as proficient, even though their reported measurement results pave the way...

  4. Lawrence Livermore National Laboratory ULTRA-350 Test Bed

    Energy Technology Data Exchange (ETDEWEB)

    Hopkins, D J; Wulff, T A; Carlisle, K

    2001-04-10

    LLNL has many in-house designed high precision machine tools. Some of these tools include the Large Optics Diamond Turning Machine (LODTM) [1], Diamond Turning Machine No.3 (DTM-3) and two Precision Engineering Research Lathes (PERL-I and PERL-II). These machines have accuracy in the sub-micron range and in most cases position resolution in the couple of nanometers range. All of these machines are built with similar underlying technologies. The machines use capstan drive technology, laser interferometer position feedback, tachometer velocity feedback, permanent magnet (PM) brush motors and analog velocity and position loop servo compensation [2]. The machine controller does not perform any servo compensation it simply computes the differences between the commanded position and the actual position (the following error) and sends this to a D/A for the analog servo position loop. LLNL is designing a new high precision diamond turning machine. The machine is called the ULTRA 350 [3]. In contrast to many of the proven technologies discussed above, the plan for the new machine is to use brushless linear motors, high precision linear scales, machine controller motor commutation and digital servo compensation for the velocity and position loops. Although none of these technologies are new and have been in use in industry, applications of these technologies to high precision diamond turning is limited. To minimize the risks of these technologies in the new machine design, LLNL has established a test bed to evaluate these technologies for application in high precision diamond turning. The test bed is primarily composed of commercially available components. This includes the slide with opposed hydrostatic bearings, the oil system, the brushless PM linear motor, the two-phase input three-phase output linear motor amplifier and the system controller. The linear scales are not yet commercially available but use a common electronic output format. As of this writing, the final

  5. Lawrence Livermore National Laboratory ULTRA-350 Test Bed

    Energy Technology Data Exchange (ETDEWEB)

    Hopkins, D J; Wulff, T A; Carlisle, K

    2001-04-10

    LLNL has many in-house designed high precision machine tools. Some of these tools include the Large Optics Diamond Turning Machine (LODTM) [1], Diamond Turning Machine No.3 (DTM-3) and two Precision Engineering Research Lathes (PERL-1 and PERL-11). These machines have accuracy in the sub-micron range and in most cases position resolution in the couple of nanometers range. All of these machines are built with similar underlying technologies. The machines use capstan drive technology, laser interferometer position feedback, tachometer velocity feedback, permanent magnet (PM) brush motors and analog velocity and position loop servo compensation [2]. The machine controller does not perform any servo compensation it simply computes the differences between the commanded position and the actual position (the following error) and sends this to a D/A for the analog servo position loop. LLNL is designing a new high precision diamond turning machine. The machine is called the ULTRA 350 [3]. In contrast to many of the proven technologies discussed above, the plan for the new machine is to use brushless linear motors, high precision linear scales, machine controller motor commutation and digital servo compensation for the velocity and position loops. Although none of these technologies are new and have been in use in industry, applications of these technologies to high precision diamond turning is limited. To minimize the risks of these technologies in the new machine design, LLNL has established a test bed to evaluate these technologies for application in high precision diamond turning. The test bed is primarily composed of commercially available components. This includes the slide with opposed hydrostatic bearings, the oil system, the brushless PM linear motor, the two-phase input three-phase output linear motor amplifier and the system controller. The linear scales are not yet commercially available but use a common electronic output format. As of this writing, the final

  6. MODERN APPROACHES IN COMPLEX LABORATORY TESTING FOR DIPHTHERIA

    Directory of Open Access Journals (Sweden)

    L. A. Kraeva

    2012-01-01

    Full Text Available Abstract. The criteria of reliable validation of population protection against diphtheria on the base of two indices including quantity of antitoxic antibodies to diphtheria and avidity index have been established. For this purposes it was proposed to use the modified variant of ELISA allowed to detect both indices simultaneously. The formula of probable development of diphtheria in case of the close contact with patients or Corynebacterium diphtheriae bacteria carriers as well as determination of revaccination time have been proposed. The authors developed “The algorithm of population immunity control and assessment of non-susceptibility to diphtheria” and “The algorithm of micro biological testing of clinical samples for C. diphtheriae”.

  7. Good Laboratory Standards for Clinical Next-Generation Sequencing Cancer Panel Tests

    Directory of Open Access Journals (Sweden)

    Jihun Kim

    2017-05-01

    Full Text Available Next-generation sequencing (NGS has recently emerged as an essential component of personalized cancer medicine due to its high throughput and low per-base cost. However, no sufficient guidelines for implementing NGS as a clinical molecular pathology test are established in Korea. To ensure clinical grade quality without inhibiting adoption of NGS, a taskforce team assembled by the Korean Society of Pathologists developed laboratory guidelines for NGS cancer panel testing procedures and requirements for clinical implementation of NGS. This consensus standard proposal consists of two parts: laboratory guidelines and requirements for clinical NGS laboratories. The laboratory guidelines part addressed several important issues across multistep NGS cancer panel tests including choice of gene panel and platform, sample handling, nucleic acid management, sample identity tracking, library preparation, sequencing, analysis and reporting. Requirements for clinical NGS tests were summarized in terms of documentation, validation, quality management, and other required written policies. Together with appropriate pathologist training and international laboratory standards, these laboratory standards would help molecular pathology laboratories to successfully implement NGS cancer panel tests in clinic. In this way, the oncology community would be able to help patients to benefit more from personalized cancer medicine.

  8. Transition between grid-connected mode and islanded mode in VSI-fed microgrids

    Indian Academy of Sciences (India)

    DIBAKAR DAS; GURUNATH GURRALA; U JAYACHANDRA SHENOY

    2017-08-01

    This paper investigates the behaviour of a microgrid system during transition between grid-connected mode and islanded mode of operation. During the grid-connected mode the microgrid sources will be controlled to provide constant real and reactive power injection. During the islanded mode the sources will be controlled to provide constant voltage and frequency operation. Special control schemes are needed to ensure proper transition from constant P–Q mode to constant f–V mode and vice versa. Transition from one mode to other will introduce severe transients in the system. Two kinds of transition schemes based on the status of the off-line controller are discussed and a comparative study is presented for various step changes in the load. An additional-pole-placement-based output feedback controller augmentation during transition between the modes is proposed to reduce the transients. A static output feedback compensator design is proposed for the grid connected to island mode transition and a dynamic output feedback compensator design is proposed for resynchronisation. The performance of the output feedback controllers is tested under various operating conditions and found to be satisfactory for the tested conditions.

  9. Screening for Saponins Using the Blood Hemolysis Test. An Undergraduate Laboratory Experiment.

    Science.gov (United States)

    Sotheeswaran, Subramaniam

    1988-01-01

    Describes an experiment for undergraduate chemistry laboratories involving a chemical found in plants and some sea animals. Discusses collection and identification of material, a hemolysis test, preparation of blood-coated agar plates, and application of samples. (CW)

  10. Laboratory testing and analysis Dorris Dam Modoc National Wildlife Refuge May 24 1991

    Data.gov (United States)

    US Fish and Wildlife Service, Department of the Interior — This report presents the results of laboratory testing and stability analyses conducted for Dorris Dam located within the Modoc National Wildlife Refuge, Modoc...

  11. 78 FR 60898 - Regulation on Definition and Requirements for a Nationally Recognized Testing Laboratory...

    Science.gov (United States)

    2013-10-02

    ... Occupational Safety and Health Administration Regulation on Definition and Requirements for a Nationally..., ``definition and requirements for a nationally recognized testing laboratory'' (The Regulation). The Regulation... place all submissions, including any personal information provided, in the public docket...

  12. Laboratory testing on infiltration in single synthetic fractures

    Science.gov (United States)

    Cherubini, Claudia; Pastore, Nicola; Li, Jiawei; Giasi, Concetta I.; Li, Ling

    2017-04-01

    An understanding of infiltration phenomena in unsaturated rock fractures is extremely important in many branches of engineering for numerous reasons. Sectors such as the oil, gas and water industries are regularly interacting with water seepage through rock fractures, yet the understanding of the mechanics and behaviour associated with this sort of flow is still incomplete. An apparatus has been set up to test infiltration in single synthetic fractures in both dry and wet conditions. To simulate the two fracture planes, concrete fractures have been moulded from 3D printed fractures with varying geometrical configurations, in order to analyse the influence of aperture and roughness on infiltration. Water flows through the single fractures by means of a hydraulic system composed by an upstream and a downstream reservoir, the latter being subdivided into five equal sections in order to measure the flow rate in each part to detect zones of preferential flow. The fractures have been set at various angles of inclination to investigate the effect of this parameter on infiltration dynamics. The results obtained identified that altering certain fracture parameters and conditions produces relevant effects on the infiltration process through the fractures. The main variables influencing the formation of preferential flow are: the inclination angle of the fracture, the saturation level of the fracture and the mismatch wavelength of the fracture.

  13. [Vasculitic Peripheral Neuropathies: Clinical Features and Diagnostic Laboratory Tests].

    Science.gov (United States)

    Ogata, Katsuhisa

    2016-03-01

    Vasculitic peripheral neuropathy (VPN) occurs due to ischemic changes of peripheral nerves, resulting from a deficit of vascular blood supply due to damaged vasa nervorum leading to vasculitis. VPN usually manifests as sensorimotor or sensory disturbances accompanied by pain, presenting as a type of multiple mononeuropathy, with a scattered distribution in distal limbs. VPN may also present as a mononeuropathy, distal symmetric polyneuropathy, plexopathy, or radiculopathy. The rapidity of VPN is variable, ranging from days to months, with symptoms occasionally changing with the appearance of new lesions. Careful history taking and neurological examination provides an exact diagnosis. The most common cause of VPN is primary vasculitis predominantly affecting small vessels, including vasa nervorum, anti-neutrophil cytoplasmic antibody (ANCA)-associated vasculitis, and polyarteritis nodosa. Similar vasculitic processes can also result from a systemic collagen disorder or secondary vasculitis. Electrophysiological studies and pathological investigation of biopsied peripheral nerves and muscles are important for diagnosis of vasculitis. Serological tests, including ANCA, are useful for diagnosis of vasculitis. Accurate neurological examinations are essential for diagnosis and evaluation of clinical course.

  14. Laboratory Testing of Demand-Response Enabled Household Appliances

    Energy Technology Data Exchange (ETDEWEB)

    Sparn, B.; Jin, X.; Earle, L.

    2013-10-01

    With the advent of the Advanced Metering Infrastructure (AMI) systems capable of two-way communications between the utility's grid and the building, there has been significant effort in the Automated Home Energy Management (AHEM) industry to develop capabilities that allow residential building systems to respond to utility demand events by temporarily reducing their electricity usage. Major appliance manufacturers are following suit by developing Home Area Network (HAN)-tied appliance suites that can take signals from the home's 'smart meter,' a.k.a. AMI meter, and adjust their run cycles accordingly. There are numerous strategies that can be employed by household appliances to respond to demand-side management opportunities, and they could result in substantial reductions in electricity bills for the residents depending on the pricing structures used by the utilities to incent these types of responses.The first step to quantifying these end effects is to test these systems and their responses in simulated demand-response (DR) conditions while monitoring energy use and overall system performance.

  15. Laboratory Testing of Demand-Response Enabled Household Appliances

    Energy Technology Data Exchange (ETDEWEB)

    Sparn, B. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Jin, X. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Earle, L. [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2013-10-01

    With the advent of the Advanced Metering Infrastructure (AMI) systems capable of two-way communications between the utility's grid and the building, there has been significant effort in the Automated Home Energy Management (AHEM) industry to develop capabilities that allow residential building systems to respond to utility demand events by temporarily reducing their electricity usage. Major appliance manufacturers are following suit by developing Home Area Network (HAN)-tied appliance suites that can take signals from the home's 'smart meter,' a.k.a. AMI meter, and adjust their run cycles accordingly. There are numerous strategies that can be employed by household appliances to respond to demand-side management opportunities, and they could result in substantial reductions in electricity bills for the residents depending on the pricing structures used by the utilities to incent these types of responses. The first step to quantifying these end effects is to test these systems and their responses in simulated demand-response (DR) conditions while monitoring energy use and overall system performance.

  16. Role of the Venereal Disease Research Laboratory test in the detection of syphilis.

    Science.gov (United States)

    Diggory, P

    1983-02-01

    Of 9733 consecutive serological samples received by Portsmouth and Southampton Public Health Laboratories (PHL) and tested for syphilis, 190 (140 from men and 50 from women) gave positive results. Thirty new cases of syphilis were identified. Most sera were tested initially by both a specific antibody test (the Treponema pallidum haemaglutination (TPHA) test) and a cardiolipin test (the Venereal Disease Research Laboratory (VDRL) test). Among the 14 patients whose sera gave VDRL-positive but TPHA-negative results, 12 sera gave false-positive results. The sera of 90 patients gave TPHA-positive but VDRL-negative results; sera from only seven of these patients gave false-positive results. The VDRL test is very unlikely to identify a new case of syphilis where a TPHA test has failed to do so. The results of the survey suggest that the VDRL test should be withdrawn from initial testing for syphilis except where early primary disease is suspected.

  17. 20 CFR 404.1519k - Purchase of medical examinations, laboratory tests, and other services.

    Science.gov (United States)

    2010-04-01

    ... psychological examinations, X-rays and laboratory tests (including specialized tests, such as pulmonary function... tests, and other services. 404.1519k Section 404.1519k Employees' Benefits SOCIAL SECURITY... Standards for the Type of Referral and for Report Content § 404.1519k Purchase of medical examinations...

  18. 20 CFR 416.919k - Purchase of medical examinations, laboratory tests, and other services.

    Science.gov (United States)

    2010-04-01

    ... psychological examinations, X-rays and laboratory tests (including specialized tests, such as pulmonary function... tests, and other services. 416.919k Section 416.919k Employees' Benefits SOCIAL SECURITY ADMINISTRATION... for the Type of Referral and for Report Content § 416.919k Purchase of medical examinations...

  19. Laboratory and field tests of corrosion inhibitors for an offshore application

    Energy Technology Data Exchange (ETDEWEB)

    Skjerve, Sofie; Fuhr, Geir Gundersen; Haldogaard, Geir

    2006-03-15

    Statoil started a R and D-project in 2002 where the goal was to implement environmental friendly corrosion control at a Statoil operated oil producing field. In this project the following tasks have been addressed: 1) Reduction of the chemical consumption. 2) Documentation of the discharge level of the corrosion inhibitor. 3) Documentation of the environmental impact. 4) Development of new environmentally friendly acceptable corrosion inhibitors. 5) Laboratory and field testing of new corrosion inhibitors. This paper describes laboratory and field tests of corrosion inhibitors for this project. The field tests were carried out on an offshore oil producing installation in the North Sea. Five corrosion inhibitor suppliers with totally eleven products were taking part in this test. All the products were tested in the laboratory. The four most promising products from the laboratory tests were tested in the field during a fourteen days offshore test. Only one of the tested products gave satisfactory results from the corrosion field test. Corrosion measurements were performed both with a Zero Resistance Ammetry (ZRA) probe installed directly into a flow line and with two side streams units. One side stream unit was connected upstream the test separator and the other unit was connected downstream the test separator. (author) (tk)

  20. Laboratory Tests of the Inverse Square Law of Gravity

    Science.gov (United States)

    Schlamminger, Stephan

    2010-02-01

    Newton's inverse square force law of gravity follows directly from the fact that we live in a 3-dimensional world. For sub-millimeter length scales there may be undiscovered, extra dimensions. Such extra dimensions can be detected with inverse square law tests accessible to torsion balances. I will present an overview of two experiments that are being conducted at the University of Washington to search for gravitational-strength deviations from the inverse square law for extra dimension length scales smaller than 50 micrometers. One experiment is designed to measure the distance dependent force between closely spaced masses, whereas the second experiment is a null experiment and is only sensitive to a deviation from the inverse square law of gravity. The first experiment consists of a torsion pendulum that is suspended above a continuously rotating attractor. The attractor and the pendulum are disks with azimuthal sectors of alternating high and a low density. The torque on the pendulum disk varies as a function of the attractor angle with a 3 degree period. The amplitude of the torque signal is analyzed as a function of the separation between the pendulum and the attractor. The second experiment consists of a plate pendulum that is suspended parallel to a larger vertical plate attractor. The pendulum plate has an internal density asymmetry with a dense inlay on one half facing the attractor and another inlay on the other half on the side away from the attractor. If the inverse square law holds, the gravitational field of the attractor is uniform and the torque on the pendulum is independent of the gap between pendulum and attractor. The attractor position is modulated between a near and far position and the torque difference on the pendulum is recorded and analyzed for a possible inverse square law violation. )

  1. Distributed Operation of Interlinked AC Microgrids with Dynamic Active and Reactive Power Tuning

    DEFF Research Database (Denmark)

    Nutkani, Inam Ullah; Loh, Poh Chiang; Blaabjerg, Frede

    2013-01-01

    Microgrids are small grids formed by clustering modern generating sources, storage systems, and loads together. Being independent, the formed microgrids can, in principle, operate at their own preferred voltages and frequencies. Tying them to the mains grid or another microgrid would therefore...... require some interlinking power converters, whose control should preferably be autonomous without depending on fast communication links. Contributing to this theme of research, a distributed power management scheme has been proposed in this paper for interlinking two or more independent microgrids...... operating at different voltages and frequencies. The proposed scheme allows sources in the microgrids to concentrate more on active power harnessing, while the interlinking converters focus more on meeting the load reactive demand. If necessary, backup active power from an underloaded microgrid can also...

  2. Optimal Sizing and Sitting of Smart Microgrid Units under Pool Electricity Market

    DEFF Research Database (Denmark)

    Hajizadeh, Amin; Hakimi, Mehdi; Moghaddas tafreshi, Masoud

    2017-01-01

    This paper presents an approach for optimal sizing and sitting of distribution generation units in smart microgrid under pool electricity market to reduce total cost and power loss of whole smart microgrid. The costs comprise capital cost, replacement cost, operation and maintenance cost, fuel cost......, reliability cost, power loss cost and selling and buying electricity cost. The new idea of this paper is the investigation of pool electricity market aspects in optimization of smart microgrid. On the other hand, cost minimization of smart microgrid is related to their bidding strategies. Therefore two...... different optimization tools are considered. First, a game-theoretical (GT) model has been used for bidding strategy of smart microgrid as a price-maker, in a long-term electricity market. Secondly, a particle swarm optimization (PSO) algorithm is employed to obtain the best cost value of smart microgrids...

  3. Multilayer PV-storage Microgrids Algorithm for the Dispatch of Distributed Network

    Directory of Open Access Journals (Sweden)

    Yang Ping

    2016-01-01

    Full Text Available In recent years, due to the support of our country, PV-storage microgrid develops rapidly. However, the flexible network operation modes of PV-storage microgrid change flexibly and the operating characteristics with a large amout of sources is highly complicated. Based on the existing microgrid coordinate control methods, this paper proposes multilayer PV-storage microgrid algorithm for fitting dispatch of distributed network, which achieves maximum output of renewable energy when meeting the scheduling requirements of network, by building PV-storage microgrid type dynamic simulation system in a variety of conditions in PSCAD. Simulation results show that the heuristic algorithm proposed can achieve microgrid stable operation and satisfy the demands of the dispatch in distributed network.

  4. Adaptive suboptimal second-order sliding mode control for microgrids

    Science.gov (United States)

    Incremona, Gian Paolo; Cucuzzella, Michele; Ferrara, Antonella

    2016-09-01

    This paper deals with the design of adaptive suboptimal second-order sliding mode (ASSOSM) control laws for grid-connected microgrids. Due to the presence of the inverter, of unpredicted load changes, of switching among different renewable energy sources, and of electrical parameters variations, the microgrid model is usually affected by uncertain terms which are bounded, but with unknown upper bounds. To theoretically frame the control problem, the class of second-order systems in Brunovsky canonical form, characterised by the presence of matched uncertain terms with unknown bounds, is first considered. Four adaptive strategies are designed, analysed and compared to select the most effective ones to be applied to the microgrid case study. In the first two strategies, the control amplitude is continuously adjusted, so as to arrive at dominating the effect of the uncertainty on the controlled system. When a suitable control amplitude is attained, the origin of the state space of the auxiliary system becomes attractive. In the other two strategies, a suitable blend between two components, one mainly working during the reaching phase, the other being the predominant one in a vicinity of the sliding manifold, is generated, so as to reduce the control amplitude in steady state. The microgrid system in a grid-connected operation mode, controlled via the selected ASSOSM control strategies, exhibits appreciable stability properties, as proved theoretically and shown in simulation.

  5. MAS Based Event-Triggered Hybrid Control for Smart Microgrids

    DEFF Research Database (Denmark)

    Dou, Chunxia; Liu, Bin; Guerrero, Josep M.

    2013-01-01

    This paper is focused on an advanced control for autonomous microgrids. In order to improve the performance regarding security and stability, a hierarchical decentralized coordinated control scheme is proposed based on multi-agents structure. Moreover, corresponding to the multi-mode and the hybr...

  6. Imaging polarimetry in the LWIR with microgrid polarimeters

    Directory of Open Access Journals (Sweden)

    Tyo J.S.

    2010-06-01

    Full Text Available Microgrid polarimeters have emerged over the past decade as a viable tool for performing real-time, highly accurate polarimetric imagery. A microgrid polarimeter operates by integrating a focal plane array (FPA with an array of micropolarizing optics. Mircrogrids have the advantage of being relatively compact, rugged, and inherently spatiotemporally aligned. However, they have the single disadvantage that the various polarization measurements that go into estimating the Stokes parameters at a particular pixel are actually coming from separate locations in the field. Hence, a microgrid polarimeter performs best where there is no image information, obviating the need for an imaging polarimeter! Recently we have been working with a LWIR microgrid polarimeter at the College of Optical Sciences. Our instrument is a DRS Sensors & Targeting Systems 640 x 480 HgCdTe FPA with linear polarizers at 0°, 45°, 90°, and 135° [1]. In this paper we will review our recent results that derive methods for artifact-free reconstruction of band limited imagery.

  7. New Perspectives on Droop Control in AC MicroGrid

    DEFF Research Database (Denmark)

    Sun, Yao; Hou, Xiaochao; Yang, Jian

    2017-01-01

    Virtual impedance, angle droop and frequency droop control play important roles in maintaining system stability, and load sharing among distributed generators (DGs) in microgrid. These approaches have been developed into three totally independent concepts, but present strong relevance. In this le...

  8. Intelligent Control for a DC Micro-Grid System

    DEFF Research Database (Denmark)

    Martino, Michele; Quiñones, Yamshid Farhat; Raboni, Pietro

    2012-01-01

    This paper presents the dynamic response of a DC–micro-grid (DC-MG) controlled in master-slave mode. The benefits of the micro-grids (MGs) are the low cost in terms of power electronics converters and the high reliability and quality, even in case of loss connection to the transmission system. A DC...

  9. Distributed Cooperative Secondary Control of Microgrids Using Feedback Linearization

    DEFF Research Database (Denmark)

    Bidram, Ali; Davoudi, Ali; Lewis, Frank;

    2013-01-01

    This paper proposes a secondary voltage control of microgrids based on the distributed cooperative control of multi-agent systems. The proposed secondary control is fully distributed; each distributed generator (DG) only requires its own information and the information of some neighbors...

  10. Efficient Energy Management for a Grid-Tied Residential Microgrid

    DEFF Research Database (Denmark)

    Anvari-Moghaddam, Amjad; Guerrero, Josep M.; Quintero, Juan Carlos Vasquez

    2017-01-01

    In this paper, an effective energy management system (EMS) for application in integrated building and microgrid system is introduced and implemented as a multi-objective optimization problem. The proposed architecture covers different key modelling aspects such as distributed heat and electricity...

  11. Adaptive control for solar energy based DC microgrid system development

    Science.gov (United States)

    Zhang, Qinhao

    During the upgrading of current electric power grid, it is expected to develop smarter, more robust and more reliable power systems integrated with distributed generations. To realize these objectives, traditional control techniques are no longer effective in either stabilizing systems or delivering optimal and robust performances. Therefore, development of advanced control methods has received increasing attention in power engineering. This work addresses two specific problems in the control of solar panel based microgrid systems. First, a new control scheme is proposed for the microgrid systems to achieve optimal energy conversion ratio in the solar panels. The control system can optimize the efficiency of the maximum power point tracking (MPPT) algorithm by implementing two layers of adaptive control. Such a hierarchical control architecture has greatly improved the system performance, which is validated through both mathematical analysis and computer simulation. Second, in the development of the microgrid transmission system, the issues related to the tele-communication delay and constant power load (CPL)'s negative incremental impedance are investigated. A reference model based method is proposed for pole and zero placements that address the challenges of the time delay and CPL in closed-loop control. The effectiveness of the proposed modeling and control design methods are demonstrated in a simulation testbed. Practical aspects of the proposed methods for general microgrid systems are also discussed.

  12. International Microgrid Assessment. Governance, INcentives, and Experience (IMAGINE)

    Energy Technology Data Exchange (ETDEWEB)

    Marnay, Chris [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Zhou, Nan [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Qu, Min [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Romankiewicz, John [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2012-06-01

    Microgrids can provide an avenue for increasing the amount of distributed generation and delivery of electricity, where control is more dispersed and quality of service is locally tailored to end-use requirements. Much of this functionality is very different from the predominant utility model to date of centralized power production which is then transmitted and distributed across long distances with a uniform quality of service. This different functionality holds much promise for positive change, in terms of increasing reliability, energy efficiency, and renewable energy while decreasing and carbon emissions. All of these functions should provide direct cost savings for customers and utilities as well as positive externalities for society. As we have seen from the international experience, allowing microgrids to function in parallel with the grid requires some changes in electricity governance and incentives to capture cost savings and actively price in positive externalities. If China can manage to implement these governance changes and create those incentive policies, it will go beyond the establishment of a successful microgrid demonstration program and become an international leader in microgrid deployment.

  13. Secondary Voltage Control for Harmonics Suppression in Islanded Microgrids

    DEFF Research Database (Denmark)

    Wang, Xiongfei; Guerrero, Josep M.; Blaabjerg, Frede

    2011-01-01

    This paper proposes a secondary voltage waveform control approach to suppress harmonics in islanded microgrids. Compared with the secondary control for traditional large power systems, the proposed control scheme can regulate the voltage waveform instead of voltage magnitude of sensitive buses in...

  14. Autonomous economic operation of grid connected DC microgrid

    DEFF Research Database (Denmark)

    Nutkani, Inam Ullah; Wang, Peng; Loh, Poh Chiang

    2014-01-01

    with the centralized management approach. In this paper, the same concept has been extended to grid-connected DC microgrid. The proposed economic droop scheme takes into consideration the power generation cost of Distributed Generators (DGs) and utility grid tariff and adaptively tunes their respective droop curves...

  15. Experimental evaluation of voltage unbalance compensation in an islanded microgrid

    DEFF Research Database (Denmark)

    Savaghebi, Mehdi; Guerrero, Josep M.; Jalilian, Alireza

    2011-01-01

    In this paper, a method for voltage unbalance compensation in an islanded microgrid based on the proper control of distributed generators (DGs) interface converter is proposed. In this method, active and reactive power control loops are considered to control the power sharing among the DGs. Also...

  16. Dynamic Energy Management System for a Smart Microgrid.

    Science.gov (United States)

    Venayagamoorthy, Ganesh Kumar; Sharma, Ratnesh K; Gautam, Prajwal K; Ahmadi, Afshin

    2016-08-01

    This paper presents the development of an intelligent dynamic energy management system (I-DEMS) for a smart microgrid. An evolutionary adaptive dynamic programming and reinforcement learning framework is introduced for evolving the I-DEMS online. The I-DEMS is an optimal or near-optimal DEMS capable of performing grid-connected and islanded microgrid operations. The primary sources of energy are sustainable, green, and environmentally friendly renewable energy systems (RESs), e.g., wind and solar; however, these forms of energy are uncertain and nondispatchable. Backup battery energy storage and thermal generation were used to overcome these challenges. Using the I-DEMS to schedule dispatches allowed the RESs and energy storage devices to be utilized to their maximum in order to supply the critical load at all times. Based on the microgrid's system states, the I-DEMS generates energy dispatch control signals, while a forward-looking network evaluates the dispatched control signals over time. Typical results are presented for varying generation and load profiles, and the performance of I-DEMS is compared with that of a decision tree approach-based DEMS (D-DEMS). The robust performance of the I-DEMS was illustrated by examining microgrid operations under different battery energy storage conditions.

  17. High Penetration of Electrical Vehicles in Microgrids: Threats and Opportunities

    Science.gov (United States)

    Khederzadeh, Mojtaba; Khalili, Mohammad

    2014-10-01

    Given that the microgrid concept is the building block of future electric distribution systems and electrical vehicles (EVs) are the future of transportation market, in this paper, the impact of EVs on the performance of microgrids is investigated. Demand-side participation is used to cope with increasing demand for EV charging. The problem of coordination of EV charging and discharging (with vehicle-to-grid (V2G) functionality) and demand response is formulated as a market-clearing mechanism that accepts bids from the demand and supply sides and takes into account the constraints put forward by different parts. Therefore, a day-ahead market with detailed bids and offers within the microgrid is designed whose objective is to maximize the social welfare which is the difference between the value that consumers attach to the electrical energy they buy plus the benefit of the EV owners participating in the V2G functionality and the cost of producing/purchasing this energy. As the optimization problem is a mixed integer nonlinear programming one, it is decomposed into one master problem for energy scheduling and one subproblem for power flow computation. The two problems are solved iteratively by interfacing MATLAB with GAMS. Simulation results on a sample microgrid with different residential, commercial and industrial consumers with associated demand-side biddings and different penetration level of EVs support the proposed formulation of the problem and the applied methods.

  18. Modeling of an autonomous microgrid for renewable energy sources integration

    DEFF Research Database (Denmark)

    Serban, I.; Teodorescu, Remus; Guerrero, Josep M.

    2009-01-01

    The frequency stability analysis in an autonomous microgrid (MG) with renewable energy sources (RES) is a continuously studied issue. This paper presents an original method for modeling an autonomous MG with a battery energy storage system (BESS) and a wind power plant (WPP), with the purpose...

  19. Improved Control Strategy for Microgrid Ultracapacitor Energy Storage Systems

    Directory of Open Access Journals (Sweden)

    Xiaobo Dou

    2014-12-01

    Full Text Available Ultracapacitors (UCs, with their features of high power density and high current charge-discharge, have become the best choice for dynamic power compensation to improve the stability of microgrids and are increasingly being applied in microgrids. This paper presents the control of an energy storage system (ESS based on ultracapacitors in the context of grid-connected microgrids. The ESS is composed of DC/AC and DC/DC converters tied by a dc link. An improved dynamic model for the ESS is proposed. Based on the proposed model a Proportional-Integral-Resonant (PIR DC link voltage controller is proposed to maintain the DC link voltage through the charging-discharging control of ultracapacitors, capable of working properly under all operating conditions. An extra double frequency component is injected into the UC current by a R controller to dynamically compensate for DC instantaneous power and double frequency AC instantaneous power due to unbalanced grid conditions and disturbances. This feature maintains the DC link voltage constant under unbalanced conditions and increases the degrees of freedom of the DC/AC converter and thus facilitates the application of UCs in microgrids. Simulation and experimental results verify the effectiveness of the proposed control strategy.

  20. Unnecessary repeat requesting of tests: an audit in a government hospital immunology laboratory.

    Science.gov (United States)

    Kwok, J; Jones, B

    2005-05-01

    Unnecessary repeat requesting of tests can make up a large proportion of a laboratory's workload. This audit set out to establish the size of this problem and to identify the circumstances under which these repeat requests were made in a government tertiary hospital immunology laboratory. The numbers of tests for immunoglobulin measurement, common autoantibodies, and tumour markers that were repeated over a 12 month period were analysed by interrogating the Delphic laboratory computer system using a management information system for raw data enquiry protocol. Repeat requests within 12 weeks of a previous request made up 16.78% of the total workload. The total cost of the tests was estimated at 132 151 US dollars. The waste of technician time and reagents as a result of unnecessary repeat testing is excessive. Many of these tests might be eliminated with the use of interventions such as computerised reminders.

  1. Evaluation of a laboratory test to detect resistance to closantel in Haemonchus contortus.

    Science.gov (United States)

    Lloyd, J B; Fitzgibbon, C C; Barchia, I

    2000-10-01

    To evaluate a laboratory test for closantel resistance in Haemonchus contortus. Field isolates of H contortus, known to be resistant to closantel, were tested in the assay. In addition, mixtures of closantel-susceptible and closantel-resistant laboratory reference strains were tested to develop a method of predicting the proportion of resistant worms in a sample from the field. The assay correctly identified as resistant all of the closantel-resistant field isolates of H contortus. It also identified one isolate with an in vivo efficacy of 98% as having emerging resistance. Testing of the mixtures of laboratory reference strains revealed that an isolate would be classified as resistant when it consists of about 25% or more resistant worms. Test samples that are not fully susceptible yet contain less than 25% resistant worms may be classified as emerging resistance. The in vitro migration assay is a sensitive method of detecting closantel resistance in H contortus.

  2. Development of Middleware Applied to Microgrids by Means of an Open Source Enterprise Service Bus

    Directory of Open Access Journals (Sweden)

    Jesús Rodríguez-Molina

    2017-02-01

    Full Text Available The success of the smart grid relies heavily on the integration of Distributed Energy Resources (DERs and interoperability among the hardware elements that are present as part of either the smart grid itself or in a smaller size deployment, such as a microgrid. Therefore, establishing an accurate design for software architectures that guarantee interoperability and are able to abstract hardware heterogeneity in this application domain, along with a clearly defined procedure on how to implement and test a solution like this, becomes a desirable objective. This paper describes the requirements needed to design a secure, decentralized and semantic middleware architecture for microgrids and the procedures used to develop it, so that the mandatory software components that have to be encased by the solution, as well as the steps that should be followed to make it happen, become clear for any designer, software architect or programmer that has to tackle similar challenges. In order to demonstrate the usability of the ideas put forward here, two successful pilots where middleware solutions were created according to these principles have been described.

  3. Reliability Evaluation of a Distribution Network with Microgrid Based on a Combined Power Generation System

    Directory of Open Access Journals (Sweden)

    Hao Bai

    2015-02-01

    Full Text Available Distributed generation (DG, battery storage (BS and electric vehicles (EVs in a microgrid constitute the combined power generation system (CPGS. A CPGS can be applied to achieve a reliable evaluation of a distribution network with microgrids. To model charging load and discharging capacity, respectively, the EVs in a CPGS can be divided into regular EVs and ruleless EVs, according to their driving behavior. Based on statistical data of gasoline-fueled vehicles and the probability distribution of charging start instant and charging time, a statistical model can be built to describe the charging load and discharging capacity of ruleless EVs. The charge and discharge curves of regular EVs can also be drawn on the basis of a daily dispatch table. The CPGS takes the charge and discharge curves of EVs, daily load and DG power generation into consideration to calculate its power supply time during islanding. Combined with fault duration, the power supply time during islanding will be used to analyze and determine the interruption times and interruption duration of loads in islands. Then the Sequential Monte Carlo method is applied to complete the reliability evaluation of the distribution system. The RBTS Bus 4 test system is utilized to illustrate the proposed technique. The effects on the system reliability of BS capacity and V2G technology, driving behavior, recharging mode and penetration of EVs are all investigated.

  4. Harnessing the Flexibility of Thermostatic Loads in Microgrids with Solar Power Generation

    Directory of Open Access Journals (Sweden)

    Rosa Morales González

    2016-07-01

    Full Text Available This paper presents a demand response (DR framework that intertwines thermodynamic building models with a genetic algorithm (GA-based optimization method. The framework optimizes heating/cooling schedules of end-users inside a business park microgrid with local distributed generation from renewable energy sources (DG-RES based on two separate objectives: net load minimization and electricity cost minimization. DG-RES is treated as a curtailable resource in anticipation of future scenarios where the infeed of DG-RES to the regional distribution network could be limited. We test the DR framework with a case study of a refrigerated warehouse and an office building located in a business park with local PV generation. Results show the technical potential of the DR framework in harnessing the flexibility of the thermal masses from end-user sites in order to: (1 reduce the energy exchange at the point of connection; (2 reduce the cost of electricity for the microgrid end-users; and (3 increase the local utilization of DG-RES in cases where DG-RES exports to the grid are restricted. The results of this work can aid end-users and distribution network operators to reduce energy costs and energy consumption.

  5. Laboratory Diagnosis of Syphilis: A Survey to Examine the Range of Tests Used in Canada

    Directory of Open Access Journals (Sweden)

    Raymond SW. Tsang

    2011-01-01

    Full Text Available Laboratory diagnosis of syphilis has undergone major changes in the past decade with the introduction of immunoassays and recombinant Treponema pallidum antigens as screening tools for syphilis infection. To address this change in laboratory practice, a national syphilis laboratory working group was established with members from the Public Health Agency of Canada, provincial public health laboratories across the country as well as sexually transmitted infection researchers, clinicians and epidemiologists. This working group aims to examine how the use of newer immunoassays will affect syphilis diagnosis, surveillance and disease management. To provide a baseline for this work, an e-mail survey was conducted in the fall of 2009 to determine current laboratory practices for syphilis diagnosis in Canada. The most commonly used tests were rapid plasma reagin, enzyme immunoassay, T pallidum passive particle agglutination, venereal disease research laboratory, fluorescent treponemal antibody absorption, line immunoassay and polymerase chain reaction with 92%, 36%, 32%, 20%, 12%, 12% and 12% of the responding laboratories reporting using these tests, respectively. The ultimate goal of this working group will be to update laboratory guidelines for the diagnosis of syphilis, and to identify syphilis surveillance and research priorities in Canada.

  6. Laboratory diagnosis of syphilis: A survey to examine the range of tests used in Canada.

    Science.gov (United States)

    Tsang, Raymond Sw; Radons, Sandra Michelle; Morshed, Muhammad

    2011-01-01

    Laboratory diagnosis of syphilis has undergone major changes in the past decade with the introduction of immunoassays and recombinant Treponema pallidum antigens as screening tools for syphilis infection. To address this change in laboratory practice, a national syphilis laboratory working group was established with members from the Public Health Agency of Canada, provincial public health laboratories across the country as well as sexually transmitted infection researchers, clinicians and epidemiologists. This working group aims to examine how the use of newer immunoassays will affect syphilis diagnosis, surveillance and disease management. To provide a baseline for this work, an e-mail survey was conducted in the fall of 2009 to determine current laboratory practices for syphilis diagnosis in Canada. The most commonly used tests were rapid plasma reagin, enzyme immunoassay, T pallidum passive particle agglutination, venereal disease research laboratory, fluorescent treponemal antibody absorption, line immunoassay and polymerase chain reaction with 92%, 36%, 32%, 20%, 12%, 12% and 12% of the responding laboratories reporting using these tests, respectively. The ultimate goal of this working group will be to update laboratory guidelines for the diagnosis of syphilis, and to identify syphilis surveillance and research priorities in Canada.

  7. Stability Enhancement Based on Virtual Impedance for DC Microgrids with Constant Power Loads

    OpenAIRE

    Lu, Xiaonan; Sun, Kai; Guerrero, Josep M.; Quintero, Juan Carlos Vasquez; Huang, Lipei; Wang, Jianhui

    2015-01-01

    In this paper, a converter-based DC microgrid is studied. By considering the impact of each component in DC microgrids on system stability, a multi-stage configuration is employed, which includes the source stage, interface converter stage between buses and common load stage. In order to study the overall stability of the above DC microgrid with constant power loads (CPLs), a comprehensive small-signal model is derived by analyzing the interface converters in each stage. The instability issue...

  8. Feasibility and Guidelines for the Development of Microgrids on Campus-Type Facilities

    Science.gov (United States)

    2012-04-01

    FINAL REPORT Feasibility and Guidelines for the Development of Microgrids in Campus-Type Facilities SERDP Project EW-1710 APRIL 2012...Feasibility and Guidelines for the Development of Microgrids on Campus-Type Facilities 5a. CONTRACT NUMBER 09-C-0058 5b. GRANT NUMBER...Development of Microgrids in Campus-Type Facilities”, sponsored by the Department of Defense (DoD)’s Strategic Environmental Research and Development

  9. Laboratory tests in the detection of extended spectrum beta-lactamase production: National Committee for Clinical Laboratory Standards (NCCLS screening test, the E-test, the double disk confirmatory test, and cefoxitin susceptibility testing

    Directory of Open Access Journals (Sweden)

    Pedro A. d'Azevedo

    2004-10-01

    Full Text Available Extended spectrum beta-lactamase (ESBL production by Klebsiella sp. and E. coli is an emerging problem. In this study, 107 clinical isolates (53 E. coli, 47 K. pneumoniae and 7 K. oxytoca screened as ESBL producers by the NCCLS disk diffusion procedure were submitted to a double disk confirmatory test (DDT and to the E-test double strip for confirmation of ESBL production by demonstration of clavulanic acid inhibition effect (CAIE. Only 72/107 (67% of the isolates were confirmed as ESBL producers by DDT, with diverse results among species. By the E-test, 58/107 (54% isolates were confirmed as ESBL producers, and 18/107 (17% were not determinable. Susceptibility to cefoxitin was found in 57/68 (83% of strains that did not show CAIE. ESBL detection remains a controversial issue and clinical laboratories are in need of a simple and effective way to recognize strains with this kind of resistance.

  10. Design and Implementation of Real-Time Intelligent Control and Structure Based on Multi-Agent Systems in Microgrids

    Directory of Open Access Journals (Sweden)

    Ming-Tse Kuo

    2013-11-01

    Full Text Available By consulting various worldwide definitions of microgrids and distributed energy, this study presents a microgrid-structured multi-agent system and uses Matlab/Simulink to construct a circuit with microgrid features, which enables the changes in each electrical source and load in the microgrid to be monitored and controlled. This multi-agent system adheres to the Java Agent Development Framework (JADE platform specifications of the Foundation for Intelligent Physical Agents (FIPA, facilitating communication, information transfers, and the receipt of real-time information regarding the microgrid and each component in the microgrid. Furthermore, the real-time state in the microgrid can be correspondingly controlled, achieving the most efficient real-time monitoring and control for electrical sources and load management in the microgrid.

  11. Laboratory Tests

    Science.gov (United States)

    ... specific genetic defects. This is particularly true of Severe Combined Immune Deficiency (SCID) where more than 12 different ... receptors. Looking to the Future Newborn screening for severe T-cell immunodeficiency is now recommended by the Secretary of the ...

  12. Laboratory Tests

    Science.gov (United States)

    ... evaluation of large parts of or the entire genetic code for an individual at relatively low cost. These ... of personalized medicine based on an individual’s unique genetic code, but when this will become reality at a ...

  13. Auction-based distributed efficient economic operations of microgrid systems

    Science.gov (United States)

    Zou, Suli; Ma, Zhongjing; Liu, Xiangdong

    2014-12-01

    This paper studies the economic operations of the microgrid in a distributed way such that the operational schedule of each of the units, like generators, load units, storage units, etc., in a microgrid system, is implemented by autonomous agents. We apply and generalise the progressive second price (PSP) auction mechanism which was proposed by Lazar and Semret to efficiently allocate the divisible network resources. Considering the economic operation for the microgrid systems, the generators play as sellers to supply energy and the load units play as the buyers to consume energy, while a storage unit, like battery, super capacitor, etc., may transit between buyer and seller, such that it is a buyer when it charges and becomes a seller when it discharges. Furthermore in a connected mode, each individual unit competes against not only the other individual units in the microgrid but also the exogenous main grid possessing fixed electricity price and infinite trade capacity; that is to say, the auctioneer assigns the electricity among all individual units and the main grid with respect to the submitted bid strategies of all individual units in the microgrid in an economic way. Due to these distinct characteristics, the underlying auction games are distinct from those studied in the literature. We show that under mild conditions, the efficient economic operation strategy is a Nash equilibrium (NE) for the PSP auction games, and propose a distributed algorithm under which the system can converge to an NE. We also show that the performance of worst NE can be bounded with respect to the system parameters, say the energy trading price with the main grid, and based upon that, the implemented NE is unique and efficient under some conditions.

  14. Managing risks of market price uncertainty for a microgrid operation

    Science.gov (United States)

    Raghavan, Sriram

    After deregulation of electricity in the United States, the day-ahead and real-time markets allow load serving entities and generation companies to bid and purchase/sell energy under the supervision of the independent system operator (ISO). The electricity market prices are inherently uncertain, and can be highly volatile. The main objective of this thesis is to hedge against the risk from the uncertainty of the market prices when purchasing/selling energy from/to the market. The energy manager can also schedule distributed generators (DGs) and storage of the microgrid to meet the demand, in addition to energy transactions from the market. The risk measure used in this work is the variance of the uncertain market purchase/sale cost/revenue, assuming the price following a Gaussian distribution. Using Markowitz optimization, the risk is minimized to find the optimal mix of purchase from the markets. The problem is formulated as a mixed integer quadratic program. The microgrid at Illinois Institute of Technology (IIT) in Chicago, IL was used as a case study. The result of this work reveals the tradeoff faced by the microgrid energy manager between minimizing the risk and minimizing the mean of the total operating cost (TOC) of the microgrid. With this information, the microgrid energy manager can make decisions in the day-ahead and real-time markets according to their risk aversion preference. The assumption of market prices following Gaussian distribution is also verified to be reasonable for the purpose of hedging against their risks. This is done by comparing the result of the proposed formulation with that obtained from the sample market prices randomly generated using the distribution of actual historic market price data.

  15. Modeling and optimization of energy storage system for microgrid

    Science.gov (United States)

    Qiu, Xin

    The vanadium redox flow battery (VRB) is well suited for the applications of microgrid and renewable energy. This thesis will have a practical analysis of the battery itself and its application in microgrid systems. The first paper analyzes the VRB use in a microgrid system. The first part of the paper develops a reduced order circuit model of the VRB and analyzes its experimental performance efficiency during deployment. The statistical methods and neural network approximation are used to estimate the system parameters. The second part of the paper addresses the implementation issues of the VRB application in a photovoltaic-based microgrid system. A new dc-dc converter was proposed to provide improved charging performance. The paper was published on IEEE Transactions on Smart Grid, Vol. 5, No. 4, July 2014. The second paper studies VRB use within a microgrid system from a practical perspective. A reduced order circuit model of the VRB is introduced that includes the losses from the balance of plant including system and environmental controls. The proposed model includes the circulation pumps and the HVAC system that regulates the environment of the VRB enclosure. In this paper, the VRB model is extended to include the ESS environmental controls to provide a model that provides a more realistic efficiency profile. The paper was submitted to IEEE Transactions on Sustainable Energy. Third paper discussed the optimal control strategy when VRB works with other type of battery in a microgird system. The work in first paper is extended. A high level control strategy is developed to coordinate a lead acid battery and a VRB with reinforcement learning. The paper is to be submitted to IEEE Transactions on Smart Grid.

  16. Optimal load scheduling in commercial and residential microgrids

    Science.gov (United States)

    Ganji Tanha, Mohammad Mahdi

    Residential and commercial electricity customers use more than two third of the total energy consumed in the United States, representing a significant resource of demand response. Price-based demand response, which is in response to changes in electricity prices, represents the adjustments in load through optimal load scheduling (OLS). In this study, an efficient model for OLS is developed for residential and commercial microgrids which include aggregated loads in single-units and communal loads. Single unit loads which include fixed, adjustable and shiftable loads are controllable by the unit occupants. Communal loads which include pool pumps, elevators and central heating/cooling systems are shared among the units. In order to optimally schedule residential and commercial loads, a community-based optimal load scheduling (CBOLS) is proposed in this thesis. The CBOLS schedule considers hourly market prices, occupants' comfort level, and microgrid operation constraints. The CBOLS' objective in residential and commercial microgrids is the constrained minimization of the total cost of supplying the aggregator load, defined as the microgrid load minus the microgrid generation. This problem is represented by a large-scale mixed-integer optimization for supplying single-unit and communal loads. The Lagrangian relaxation methodology is used to relax the linking communal load constraint and decompose the independent single-unit functions into subproblems which can be solved in parallel. The optimal solution is acceptable if the aggregator load limit and the duality gap are within the bounds. If any of the proposed criteria is not satisfied, the Lagrangian multiplier will be updated and a new optimal load schedule will be regenerated until both constraints are satisfied. The proposed method is applied to several case studies and the results are presented for the Galvin Center load on the 16th floor of the IIT Tower in Chicago.

  17. The laboratory test rig with miniature jet engine to research aviation fuels combustion process

    OpenAIRE

    Gawron Bartosz; Białecki Tomasz

    2015-01-01

    This article presents laboratory test rig with a miniature turbojet engine (MiniJETRig – Miniature Jet Engine Test Rig), that was built in the Air Force Institute of Technology. The test rig has been developed for research and development works aimed at modelling and investigating processes and phenomena occurring in full scale jet engines. In the article construction of a test rig is described, with a brief discussion on the functionality of each of its main components. Additionally examples...

  18. Distributed Secondary Control for Islanded MicroGrids – A Networked Control Systems Approach

    DEFF Research Database (Denmark)

    Shafiee, Qobad; Vasquez, Juan Carlos; Guerrero, Josep M.

    2012-01-01

    control system is used in order to implement a distributed secondary control thus avoiding the use of a MicroGrid Central Control. The proposed approach is not only able to restore frequency and voltage of the MicroGrid but also ensures reactive power sharing. The distributed secondary control do......This paper presents a novel approach to conceive the secondary control in droop-controlled MicroGrids. The conventional approach is based on restoring the frequency and amplitude deviations produced by the local droop controllers by using a MicroGrid Central Controller. A distributed networked...

  19. Islanding Detection for Microgrid Based on Frequency Tracking Using Extended Kalman Filter Algorithm

    Directory of Open Access Journals (Sweden)

    Bin Li

    2014-01-01

    Full Text Available Islanding detection is essential for secure and reliable operation of microgrids. Considering the relationship between the power generation and the load in microgrids, frequency may vary with time when islanding occurs. As a common approach, frequency measurement is widely used to detect islanding condition. In this paper, a novel frequency calculation algorithm based on extended Kalman filter was proposed to track dynamic frequency of the microgrid. Taylor series expansion was introduced to solve nonlinear state equations. In addition, a typical microgrid model was built using MATLAB/SIMULINK. Simulation results demonstrated that the proposed algorithm achieved great stability and strong robustness in of tracking dynamic frequency.

  20. Hierarchical Control of Droop-Controlled DC and AC Microgrids - A General Approach Towards Standardization

    DEFF Research Database (Denmark)

    Guerrero, Josep M.; Vásquez, Juan V.; Teodorescu, Remus

    2009-01-01

    DC and AC Microgrids are key elements to integrate renewable and distributed energy resources as well as distributed energy storage systems. In the last years, efforts toward the standardization of these Microgrids have been made. In this sense, this paper present the hierarchical control derived...... the deviations produced by the primary control; and iii) the tertiary control manage the power flow between the microgrid and the external electrical distribution system. Results from a hierarchicalcontrolled microgrid are provided to show the feasibility of the proposed approach....