WorldWideScience

Sample records for microelectrode array-coupled bipolar

  1. Biofunctionalization of diamond microelectrodes

    Energy Technology Data Exchange (ETDEWEB)

    Reitinger, Andreas Adam; Lud, Simon Quartus; Stutzmann, Martin; Garrido, Jose Antonio [Walter Schottky Institut, TU Muenchen (Germany); Hutter, Naima Aurelia; Richter, Gerhard; Jordan, Rainer [WACKER-Chair of Macromolecular Chemistry, TU Muenchen (Germany)

    2010-07-01

    In this work we present two main routes for the biofunctionalization of nanocrystalline diamond films, aiming at the application of diamond microelectrodes as amperometric biosensors. We report on direct covalent grafting of biomolecules on nanocrystalline diamond films via diazonium monophenyls and biphenyls as well as other linker molecules, forming self-assembled monolayers on the diamond surface. Monolayers with different functional head groups have been characterized. Patterning of the available functional groups using electron beam-induced chemical lithography allows the selective preparation of well-localized docking sites for the immobilization of biomolecules. Furthermore, polymer brushes are expected to enable novel paths for designing more advanced biosensing schemes, incorporating multifunctional groups and a higher loading capacity for biomolecules. Here, we focus on the preparation of polymer grafts by self-initiated photografting and photopolymerization. Further chemical modification of the grafted polymer brushes results in the introduction of additional functional molecules, paving the way for the incorporation of more complex molecular structures such as proteins. In a comparative study we investigate the advantages and disadvantages of both approaches.

  2. Soldering of Nanotubes onto Microelectrodes

    DEFF Research Database (Denmark)

    Madsen, Dorte Nørgaard; Mølhave, Kristian; Mateiu, Ramona Valentina

    2003-01-01

    Suspended bridges of individual multiwalled carbon nanotubes were fabricated inside a scanning electron microscope by soldering the nanotube onto microelectrodes with highly conducting gold-carbon material. By the decomposition of organometallic vapor with the electron beam, metal-containing sold...... bonds were consistently found to be mechanically stronger than the carbon nanotubes.......Suspended bridges of individual multiwalled carbon nanotubes were fabricated inside a scanning electron microscope by soldering the nanotube onto microelectrodes with highly conducting gold-carbon material. By the decomposition of organometallic vapor with the electron beam, metal-containing solder...... bonds were formed at the intersection of the nanotube and the electrodes. Current-voltage curves indicated metallic conduction of the nanotubes, with resistances in the range of 9-29 kOmega. Bridges made entirely of the soldering material exhibited resistances on the order of 100 Omega, and the solder...

  3. Conducting polymer 3D microelectrodes

    DEFF Research Database (Denmark)

    Sasso, Luigi; Vazquez, Patricia; Vedarethinam, Indumathi

    2010-01-01

    Conducting polymer 3D microelectrodes have been fabricated for possible future neurological applications. A combination of micro-fabrication techniques and chemical polymerization methods has been used to create pillar electrodes in polyaniline and polypyrrole. The thin polymer films obtained...... showed uniformity and good adhesion to both horizontal and vertical surfaces. Electrodes in combination with metal/conducting polymer materials have been characterized by cyclic voltammetry and the presence of the conducting polymer film has shown to increase the electrochemical activity when compared...

  4. Bipolar Disorder

    Science.gov (United States)

    Bipolar disorder is a serious mental illness. People who have it go through unusual mood changes. They go ... The down feeling is depression. The causes of bipolar disorder aren't always clear. It runs in families. ...

  5. Pyrolytic 3D Carbon Microelectrodes for Electrochemistry

    DEFF Research Database (Denmark)

    Hemanth, Suhith; Caviglia, Claudia; Amato, Letizia

    2016-01-01

    This work presents the fabrication and characterization of suspended three-dimensional (3D) pyrolytic carbon microelectrodes for electrochemical applications. For this purpose, an optimized process with multiple steps of UV photolithography with the negative tone photoresist SU-8 followed...... by pyrolysis at 900ºC for 1h was developed. With this process, microelectrode chips with a three electrode configuration were fabricated and characterized with cyclic voltammetry (CV) using a 10mM potassium ferri-ferrocyanide redox probe in a custom made batch system with magnetic clamping. The 3D pyrolytic...... carbon microelectrodes displayed twice the higher peak current compared to 2D....

  6. Conducting Polymer 3D Microelectrodes

    Directory of Open Access Journals (Sweden)

    Jenny Emnéus

    2010-12-01

    Full Text Available Conducting polymer 3D microelectrodes have been fabricated for possible future neurological applications. A combination of micro-fabrication techniques and chemical polymerization methods has been used to create pillar electrodes in polyaniline and polypyrrole. The thin polymer films obtained showed uniformity and good adhesion to both horizontal and vertical surfaces. Electrodes in combination with metal/conducting polymer materials have been characterized by cyclic voltammetry and the presence of the conducting polymer film has shown to increase the electrochemical activity when compared with electrodes coated with only metal. An electrochemical characterization of gold/polypyrrole electrodes showed exceptional electrochemical behavior and activity. PC12 cells were finally cultured on the investigated materials as a preliminary biocompatibility assessment. These results show that the described electrodes are possibly suitable for future in-vitro neurological measurements.

  7. Fabrication of gas sensor based on field ionization from SWCNTs with tripolar microelectrode

    Science.gov (United States)

    Cai, Shengbing; Zhang, Yong; Duan, Zhemin

    2012-12-01

    We report the nanofabrication of a sulfur dioxide (SO2) sensor with a tripolar on-chip microelectrode utilizing a film of single-walled carbon nanotubes (SWCNTs) as the field ionization cathode, where the ion flow current and the partial discharge current generated by the field ionization process of gaseous molecules can be gauged to gas species and concentration. The variation of the sensitivity is less than 4% for all of the tested devices, and the sensor has selectivity against gases such as He, NO2, CO, H2, SO2 and O2. Further, the sensor response presents well-defined and reproducible linear behavior with regard to concentration in the range investigated and a detection limitation of tripolar on-chip microelectrode with SWCNTs as a cathode exhibits an impressive performance with respect to stability and anti-oxidation behavior, which are significantly better than had been possible before in the traditional bipolar sensor under explicit circumstances at room temperature.

  8. Band-type microelectrodes for amperometric immunoassays

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ga-Yeon; Chang, Young Wook; Ko, Hyuk [Department of Materials Science and Engineering, Yonsei University, 134 Shinchon-dong, Seodaemun-gu, Seoul, 120-749 (Korea, Republic of); Kang, Min-Jung [Korea Institute of Science and Technology (KIST), Seoul (Korea, Republic of); Pyun, Jae-Chul, E-mail: jcpyun@yonsei.ac.kr [Department of Materials Science and Engineering, Yonsei University, 134 Shinchon-dong, Seodaemun-gu, Seoul, 120-749 (Korea, Republic of)

    2016-07-20

    A band-type microelectrode was made using a parylene-N film as a passivation layer. A circular-type, mm-scale electrode with the same diameter as the band-type microelectrode was also made with an electrode area that was 5000 times larger than the band-type microelectrode. By comparing the amperometric signals of 3,5,3′,5′-tetramethylbenzidine (TMB) samples at different optical density (OD) values, the band-type microelectrode was determined to be 9 times more sensitive than the circular-type electrode. The properties of the circular-type and the band-type electrodes (e.g., the shape of their cyclic voltammograms, the type of diffusion layer used, and the diffusion layer thickness per unit electrode area) were characterized according to their electrode area using the COMSOL Multiphysics software. From these simulations, the band-type electrode was estimated to have the conventional microelectrode properties, even when the electrode area was 100 times larger than a conventional circular-type electrode. These results show that both the geometry and the area of an electrode can influence the properties of the electrode. Finally, amperometric analysis based on a band-type electrode was applied to commercial ELISA kits to analyze human hepatitis B surface antigen (hHBsAg) and human immunodeficiency virus (HIV) antibodies. - Highlights: • A band-type microelectrode was made using a parylene-N film as a passivation layer. • The band-type microelectrode was 14-times more sensitive than circular-type electrode. • The influence of geometry on microelectrode properties was simulated using COMSOL. • The band-type electrode was applied to ELISA kits for hHBsAg and hHIV-antibodies.

  9. Failure Mechanisms of a Gold Microelectrode in Bioelectronics Applications

    Directory of Open Access Journals (Sweden)

    Jonghun Kim

    2015-01-01

    Full Text Available The generation, growth, and collapse of tiny bubbles are inevitable for a microelectrode working in aqueous environment, thus resulting in physical damages on the microelectrode. The failure mechanisms of a microelectrode induced by tiny bubble collapsing are investigated by generating tiny hydrogen bubbles on a gold microelectrode through deionized water electrolysis. The surface of the microelectrode is modified with a thiol-functionalized arginine-glycine-aspartic acid peptide to generate perfectly spherical bubbles in proximity of the surface. The failure of an Au microelectrode is governed by two damage mechanisms, depending on the thickness of the microelectrode: a water-hammer pressure due to the violent collapse of a single large bubble, formed through merging of small bubbles, for ultrathin Au microelectrodes of 40–60 nm in thickness, and an energy accumulation resulting from the repetitive collapse of tiny bubbles for thick Au microelectrodes of 100–120 nm.

  10. Bipolar disorders

    DEFF Research Database (Denmark)

    Vieta, Eduard; Berk, Michael; Schulze, Thomas G

    2018-01-01

    Bipolar disorders are chronic and recurrent disorders that affect >1% of the global population. Bipolar disorders are leading causes of disability in young people as they can lead to cognitive and functional impairment and increased mortality, particularly from suicide and cardiovascular disease...... and accurate diagnosis is difficult in clinical practice as the onset of bipolar disorder is commonly characterized by nonspecific symptoms, mood lability or a depressive episode, which can be similar in presentation to unipolar depression. Moreover, patients and their families do not always understand...... a bipolar disorder from other conditions. Optimal early treatment of patients with evidence-based medication (typically mood stabilizers and antipsychotics) and psychosocial strategies is necessary....

  11. Bipolar Disorder.

    Science.gov (United States)

    Spearing, Melissa

    Bipolar disorder, a brain disorder that causes unusual shifts in a person's mood, affects approximately one percent of the population. It commonly occurs in late adolescence and is often unrecognized. The diagnosis of bipolar disorder is made on the basis of symptoms, course of illness, and when possible, family history. Thoughts of suicide are…

  12. Batch fabrication of nanotubes suspended between microelectrodes

    DEFF Research Database (Denmark)

    Mateiu, Ramona Valentina; Stöckli, T.; Knapp, H. F.

    2007-01-01

    be done with a simple lift-off process with standard photolithographic resist. An applied electric field is sustained between the microelectrodes during CVD to guide the nanotube growth. Comparison with simulations shows that the location and the orientation of the grown carbon nanotubes (CNT) correspond...... to the regions of maximum electric field, enabling accurate positioning of a nanotube by controlling the shape of the microelectrodes. The CNT bridges are deflected tens of nm when a DC voltage is applied between the nanotube and a gate microelectrode indicating that the clamping through the catalyst particles...... is not only mechanically stable but also electrical conducting. This method could be used to fabricate nanoelectromechanical systems based on suspended double clamped CNTs depending only on photolithography and standard Cleanroom processes....

  13. Bipolar Disorder

    Science.gov (United States)

    ... one or other traumatic event Drug or alcohol abuse Complications Left untreated, bipolar disorder can result in serious problems that affect every area of your life, such as: Problems related to drug and alcohol use Suicide or suicide attempts Legal or financial problems Damaged ...

  14. Vertically aligned carbon nanotubes for microelectrode arrays applications.

    Science.gov (United States)

    Castro Smirnov, J R; Jover, Eric; Amade, Roger; Gabriel, Gemma; Villa, Rosa; Bertran, Enric

    2012-09-01

    In this work a methodology to fabricate carbon nanotube based electrodes using plasma enhanced chemical vapour deposition has been explored and defined. The final integrated microelectrode based devices should present specific properties that make them suitable for microelectrode arrays applications. The methodology studied has been focused on the preparation of highly regular and dense vertically aligned carbon nanotube (VACNT) mat compatible with the standard lithography used for microelectrode arrays technology.

  15. Neutrality in bipolar structures

    DEFF Research Database (Denmark)

    Montero, Javier; Rodríguez, J. Tinguaro; Franco, Camilo

    2014-01-01

    In this paper, we want to stress that bipolar knowledge representation naturally allows a family of middle states which define as a consequence different kinds of bipolar structures. These bipolar structures are deeply related to the three types of bipolarity introduced by Dubois and Prade, but our...... approach offers a systematic explanation of how such bipolar structures appear and can be identified....

  16. Bipolar Treatment: Are Bipolar I and Bipolar II Treated Differently?

    Science.gov (United States)

    ... The diagnosis and management of bipolar I and bipolar II disorders: Clinical practice update. Mayo Clinic Proceedings. 2017;92:1532. Haynes PL, et al. Social rhythm therapies for mood disorders: An update. Current Psychiatry Reports. ...

  17. Bipolar electrochemistry.

    Science.gov (United States)

    Fosdick, Stephen E; Knust, Kyle N; Scida, Karen; Crooks, Richard M

    2013-09-27

    A bipolar electrode (BPE) is an electrically conductive material that promotes electrochemical reactions at its extremities (poles) even in the absence of a direct ohmic contact. More specifically, when sufficient voltage is applied to an electrolyte solution in which a BPE is immersed, the potential difference between the BPE and the solution drives oxidation and reduction reactions. Because no direct electrical connection is required to activate redox reactions, large arrays of electrodes can be controlled with just a single DC power supply or even a battery. The wireless aspect of BPEs also makes it possible to electrosynthesize and screen novel materials for a wide variety of applications. Finally, bipolar electrochemistry enables mobile electrodes, dubbed microswimmers, that are able to move freely in solution. Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Transtorno bipolar

    Directory of Open Access Journals (Sweden)

    Alda Martin

    1999-01-01

    Full Text Available Os resultados de estudos de famílias sugerem que o transtorno bipolar tenha uma base genética. Essa hipótese foi reforçada em estudos de adoção e de gêmeos. A herança do transtorno bipolar é complexa, envolve vários genes, além de apresentar heterogeneidade e interação entre fatores genéticos e não-genéticos. Achados, que já foram replicados, já implicaram os cromossomos 4, 12, 18 e 21, entre outros, na busca por genes de suscetibilidade. Os resultados mais promissores foram obtidos através de estudos de ligação. Por outro lado, os estudos de associação geraram dados interessantes, mas ainda vagos. Os estudos de populações de pacientes homogêneos e a melhor definição do fenótipo deverão contribuir para avanços futuros. A identificação dos genes relacionados ao transtorno bipolar irá permitir o melhor entendimento e tratamento dessa doença.

  19. Fabrication of three-dimensional carbon microelectrodes for electrochemical sensing

    DEFF Research Database (Denmark)

    Hemanth, Suhith

    Carbon microelectrodes have a wide range of applications because of their unique material properties and biocompatibility. The aim of the research work carried out in this thesis was to develop three-dimensional (3D) carbon microelectrodes for electrochemical applications. Three different fabrica...

  20. Electric potential microelectrode for studies of electrobiogeophysics

    DEFF Research Database (Denmark)

    Damgaard, Lars Riis; Risgaard-Petersen, Nils; Nielsen, Lars Peter

    2014-01-01

    were needle-shaped, shielded Ag/AgCl half-cells that were rendered insensitive to redox-active species in the environment. Tip diameters of 40 to 100 μm and signal resolution of approximately 10 μV were achieved. A test in marine sediments with active cable bacteria showed an electric potential......Spatially separated electron donors and acceptors in sediment can be exploited by the so-called “cable bacteria.” Electric potential microelectrodes (EPMs) were constructed to measure the electric fields that should appear when cable bacteria conduct electrons over centimeter distances. The EPMs...

  1. Fabrication of gas sensor based on field ionization from SWCNTs with tripolar microelectrode

    International Nuclear Information System (INIS)

    Cai, Shengbing; Zhang, Yong; Duan, Zhemin

    2012-01-01

    We report the nanofabrication of a sulfur dioxide (SO 2 ) sensor with a tripolar on-chip microelectrode utilizing a film of single-walled carbon nanotubes (SWCNTs) as the field ionization cathode, where the ion flow current and the partial discharge current generated by the field ionization process of gaseous molecules can be gauged to gas species and concentration. The variation of the sensitivity is less than 4% for all of the tested devices, and the sensor has selectivity against gases such as He, NO 2 , CO, H 2 , SO 2 and O 2 . Further, the sensor response presents well-defined and reproducible linear behavior with regard to concentration in the range investigated and a detection limitation of <∼0.5 ppm for SO 2 . More importantly, a tripolar on-chip microelectrode with SWCNTs as a cathode exhibits an impressive performance with respect to stability and anti-oxidation behavior, which are significantly better than had been possible before in the traditional bipolar sensor under explicit circumstances at room temperature. (paper)

  2. Screening metal nanoparticles using boron-doped diamond microelectrodes

    Energy Technology Data Exchange (ETDEWEB)

    Ivandini, Tribidasari A., E-mail: ivandini.tri@sci.ui.ac.id; Rangkuti, Prasmita K. [Department of Chemistry, FMIPA, Universitas Indonesia, Kampus UI Depok (Indonesia); Einaga, Yasuaki [Department of Chemistry, Faculty of Science and Technology, Keio University (Japan); JST ACCEL, 3-14-1 Hiyoshi, Yokohama 223-8522 (Japan)

    2016-04-19

    Boron-doped diamond (BDD) microelectrodes were used to observe the correlation between electrocatalytic currents caused by individual Pt nanoparticle (Pt-np) collisions at the electrode. The BDD microelectrodes, ∼20 µm diameter and ∼2 µm particle size, were fabricated at the surface of tungsten wires. Pt-np with a size of 1 to 5 nm with agglomerations up to 20 nm was used for observation. The electrolytic currents were observed via catalytic reaction of 15 mM hydrazine in 50 mM phosphate buffer solution at Pt-np at 0.4 V when it collides with the surface of the microelectrodes. The low current noise and wider potential window in the measurements using BDD microelectrode produced a better results, which represents a better correlation to the TEM result of the Pt-np, compared to when gold microelectrodes was used.

  3. Screening metal nanoparticles using boron-doped diamond microelectrodes

    International Nuclear Information System (INIS)

    Ivandini, Tribidasari A.; Rangkuti, Prasmita K.; Einaga, Yasuaki

    2016-01-01

    Boron-doped diamond (BDD) microelectrodes were used to observe the correlation between electrocatalytic currents caused by individual Pt nanoparticle (Pt-np) collisions at the electrode. The BDD microelectrodes, ∼20 µm diameter and ∼2 µm particle size, were fabricated at the surface of tungsten wires. Pt-np with a size of 1 to 5 nm with agglomerations up to 20 nm was used for observation. The electrolytic currents were observed via catalytic reaction of 15 mM hydrazine in 50 mM phosphate buffer solution at Pt-np at 0.4 V when it collides with the surface of the microelectrodes. The low current noise and wider potential window in the measurements using BDD microelectrode produced a better results, which represents a better correlation to the TEM result of the Pt-np, compared to when gold microelectrodes was used.

  4. Nanostructured gold microelectrodes for extracellular recording

    Energy Technology Data Exchange (ETDEWEB)

    Brueggemann, Dorothea; Wolfrum, Bernhard; Maybeck, Vanessa; Offenhaeusser, Andreas [CNI Center of Nanoelectronic Systems for Information Technology and Institute of Bio- and Nanosystems 2, Forschungszentrum Juelich (Germany)

    2010-07-01

    Electrophysiological activity of electrogenic cells is currently recorded with planar bioelectronic interfaces such as microelectrode arrays (MEAs). In this work, a novel concept of biocompatible nanostructured gold MEAs for extracellular signal recording is presented. MEAs were fabricated using clean room technologies, e.g. photolithography and metallization. Subsequently, they were modified with gold nanopillars of approximately 300 to 400 nm in height and 60 nm width. The nanostructuring process was carried out with a template-assisted approach using nanoporous aluminium oxide. Impedance spectroscopy of the resulting nanostructures showed higher capacitances compared to planar gold. This confirmed the expected increase of the surface area via nanostructuring. We used the nanostructured microelectrodes to record extracellular potentials from heart muscle cells (HL1), which were plated onto the chips. Good coupling between the HL1 cells and the nanostructured electrodes was observed. The resulting signal-to-noise ratio of nanopillar-MEAs was increased by a factor of 2 compared to planar MEAs. In future applications this nanopillar concept can be adopted for distinct interface materials and coupling to cellular and molecular sensing components.

  5. Estimation of neural energy in microelectrode signals

    Science.gov (United States)

    Gaumond, R. P.; Clement, R.; Silva, R.; Sander, D.

    2004-09-01

    We considered the problem of determining the neural contribution to the signal recorded by an intracortical electrode. We developed a linear least-squares approach to determine the energy fraction of a signal attributable to an arbitrary number of autocorrelation-defined signals buried in noise. Application of the method requires estimation of autocorrelation functions Rap(tgr) characterizing the action potential (AP) waveforms and Rn(tgr) characterizing background noise. This method was applied to the analysis of chronically implanted microelectrode signals from motor cortex of rat. We found that neural (AP) energy consisted of a large-signal component which grows linearly with the number of threshold-detected neural events and a small-signal component unrelated to the count of threshold-detected AP signals. The addition of pseudorandom noise to electrode signals demonstrated the algorithm's effectiveness for a wide range of noise-to-signal energy ratios (0.08 to 39). We suggest, therefore, that the method could be of use in providing a measure of neural response in situations where clearly identified spike waveforms cannot be isolated, or in providing an additional 'background' measure of microelectrode neural activity to supplement the traditional AP spike count.

  6. A novel combinational pH-PCO2 microelectrode.

    Science.gov (United States)

    Rao, X; Ma, Y

    1993-07-01

    A novel combinational pH-PCO2 microelectrode based on a neutral carrier hydrogen ion exchanger is described. It is easy to fabricate and allows pH and PCO2 to be measured simultaneously. The microelectrode has a 5-microns tip. The PCO2 microelectrode exhibits a linear response in the range 1.75 x 10(-5)-10(-2) mol/liter with a Nernstian slope of 57.0 mV/decade at 25 degrees C. The detection limit is 10(-5) mol/liter. The pH microelectrode exhibits a linear response in the range pH 4-12 with a Nernstian slope of 60.0 mV/decade at 25 degrees C. The 95% steady-state response time of the PCO2 microelectrode is about 2 min, while it is about 10 s for pH microelectrode. The electromotive force drift is 4.3 mV/h (PCO2) and 2.6 mV/h (pH), respectively. The lifetime is 3 to 4 days. The microelectrode can measure pH and PCO2 in body fluids simultaneously with satisfactory results. It is also a good basic electrode for enzyme microelectrolysis.

  7. Apparatus and method of inserting a microelectrode in body tissue or the like using vibration means

    Science.gov (United States)

    Feldstein, C.; Crawford, D. W.; Kanabus, E. W. (Inventor)

    1979-01-01

    An arrangement for and method of inserting a glass microelectrode having a tip in the micron range into body tissue is presented. The arrangement includes a microelectrode. The top of the microelectrode is attached to the diaphragm center of a first speaker. The microelectrode tip is brought into contact with the tissue by controlling a micromanipulator. Thereafter, an audio signal is applied to the speaker to cause the microelectrode to vibrate and thereby pierce the tissue surface without breaking the microelectrode tip. Thereafter, the tip is inserted into the tissue to the desired depth by operating the micromanipulator with the microelectrode in a vibratory or non-vibratory state.

  8. Pyrolytic 3D Carbon Microelectrodes for Electrochemistry

    DEFF Research Database (Denmark)

    Hemanth, Suhith; Caviglia, Claudia; Amato, Letizia

    2016-01-01

    electrochemical activity, chemical stability, and ease in surface functionalization [1]. The most common carbon microfabrication techniques (i.e. screen printing) produce two-dimensional (2D) electrodes, which limit the detection sensitivity. Hence several 3D microfabrication techniques have been explored......This work presents the fabrication and characterization of multi-layered three-dimensional (3D) pyrolysed carbon microelectrodes for electrochemical applications. For this purpose, an optimized UV photolithography and pyrolysis process with the negative tone photoresist SU-8 has been developed...... carbon [2]. This process enables fabrication of 2D and 3D electrodes with possibility for tailoring ad-hoc designs and unique sensitivities for specific applications. Due to this, pyrolysed carbon is becoming increasingly attractive for numerous applications, such as novel sensors and scaffolds for cell...

  9. Carbon fiber on polyimide ultra-microelectrodes

    Science.gov (United States)

    Gillis, Winthrop F.; Lissandrello, Charles A.; Shen, Jun; Pearre, Ben W.; Mertiri, Alket; Deku, Felix; Cogan, Stuart; Holinski, Bradley J.; Chew, Daniel J.; White, Alice E.; Otchy, Timothy M.; Gardner, Timothy J.

    2018-02-01

    Objective. Most preparations for making neural recordings degrade over time and eventually fail due to insertion trauma and reactive tissue response. The magnitudes of these responses are thought to be related to the electrode size (specifically, the cross-sectional area), the relative stiffness of the electrode, and the degree of tissue tolerance for the material. Flexible carbon fiber ultra-microelectrodes have a much smaller cross-section than traditional electrodes and low tissue reactivity, and thus may enable improved longevity of neural recordings in the central and peripheral nervous systems. Only two carbon fiber array designs have been described previously, each with limited channel densities due to limitations of the fabrication processes or interconnect strategies. Here, we describe a method for assembling carbon fiber electrodes on a flexible polyimide substrate that is expected to facilitate the construction of high-density recording and stimulating arrays. Approach. Individual carbon fibers were aligned using an alignment tool that was 3D-printed with sub-micron resolution using direct laser writing. Indium deposition on the carbon fibers, followed by low-temperature microsoldering, provided a robust and reliable method of electrical connection to the polyimide interconnect. Main results. Spontaneous multiunit activity and stimulation-evoked compound responses with SNR  >10 and  >120, respectively, were recorded from a small (125 µm) peripheral nerve. We also improved the typically poor charge injection capacity of small diameter carbon fibers by electrodepositing 100 nm-thick iridium oxide films, making the carbon fiber arrays usable for electrical stimulation as well as recording. Significance. Our innovations in fabrication technique pave the way for further miniaturization of carbon fiber ultra-microelectrode arrays. We believe these advances to be key steps to enable a shift from labor intensive, manual assembly to a more automated

  10. Suspended 3D pyrolytic carbon microelectrodes for electrochemistry

    DEFF Research Database (Denmark)

    Hemanth, Suhith; Caviglia, Claudia; Keller, Stephan Sylvest

    2017-01-01

    with cyclic voltammetry (CV) and impedance spectroscopy (EIS) using potassium ferri-ferrocyanide redox probe in a custom made batch system with magnetic clamping. Different 3D pyrolytic carbon microelectrodes were compared and the optimal design displayed twice the peak current and half the charge transfer......Carbon microelectrodes have a wide range of applications because of their unique material properties and biocompatibility. This work presents the fabrication and characterization of suspended pyrolytic carbon microstructures serving as three-dimensional (3D) carbon microelectrodes...... for electrochemical applications. A 3D polymer template in epoxy based photoresist (SU-8) was fabricated with multiple steps of UV photolithography and pyrolysed at 900 °C to obtain 3D carbon microelectrodes. The pyrolytic carbon microstructures were characterized by SEM, Raman spectroscopy and XPS to determine...

  11. Sonochemically Fabricated Microelectrode Arrays for Use as Sensing Platforms

    Directory of Open Access Journals (Sweden)

    Stuart D. Collyer

    2010-05-01

    Full Text Available The development, manufacture, modification and subsequent utilisation of sonochemically-formed microelectrode arrays is described for a range of applications. Initial fabrication of the sensing platform utilises ultrasonic ablation of electrochemically insulating polymers deposited upon conductive carbon substrates, forming an array of up to 70,000 microelectrode pores cm–2. Electrochemical and optical analyses using these arrays, their enhanced signal response and stir-independence area are all discussed. The growth of conducting polymeric “mushroom” protrusion arrays with entrapped biological entities, thereby forming biosensors is detailed. The simplicity and inexpensiveness of this approach, lending itself ideally to mass fabrication coupled with unrivalled sensitivity and stir independence makes commercial viability of this process a reality. Application of microelectrode arrays as functional components within sensors include devices for detection of chlorine, glucose, ethanol and pesticides. Immunosensors based on microelectrode arrays are described within this monograph for antigens associated with prostate cancer and transient ischemic attacks (strokes.

  12. Bipolar disorder in adolescence.

    Science.gov (United States)

    DeFilippis, Melissa; Wagner, Karen Dineen

    2013-08-01

    Bipolar disorder is a serious psychiatric condition that may have onset in childhood. It is important for physicians to recognize the symptoms of bipolar disorder in children and adolescents in order to accurately diagnose this illness early in its course. Evidence regarding the efficacy of various treatments is necessary to guide the management of bipolar disorder in youth. For example, several medications commonly used for adults with bipolar disorder have not shown efficacy for children and adolescents with bipolar disorder. This article reviews the prevalence, diagnosis, course, and treatment of bipolar disorder in children and adolescents and provides physicians with information that will aid in diagnosis and treatment.

  13. Electrical Characterization of 3D Au Microelectrodes for Use in Retinal Prostheses.

    Science.gov (United States)

    Lee, Sangmin; Ahn, Jae Hyun; Seo, Jong-Mo; Chung, Hum; Cho, Dong-Il Dan

    2015-06-17

    In order to provide high-quality visual information to patients who have implanted retinal prosthetic devices, the number of microelectrodes should be large. As the number of microelectrodes is increased, the dimensions of each microelectrode must be decreased, which in turn results in an increased microelectrode interface impedance and decreased injection current dynamic range. In order to improve the trade-off envelope between the number of microelectrodes and the current injection characteristics, a 3D microelectrode structure can be used as an alternative. In this paper, the electrical characteristics of 2D and 3D Au microelectrodes were investigated. In order to examine the effects of the structural difference, 2D and 3D Au microelectrodes with different base areas but similar effective surface areas were fabricated and evaluated. Interface impedances were measured and similar dynamic ranges were obtained for both 2D and 3D Au microelectrodes. These results indicate that more electrodes can be implemented in the same area if 3D designs are used. Furthermore, the 3D Au microelectrodes showed substantially enhanced electrical durability characteristics against over-injected stimulation currents, withstanding electrical currents that are much larger than the limit measured for 2D microelectrodes of similar area. This enhanced electrical durability property of 3D Au microelectrodes is a new finding in microelectrode research, and makes 3D microelectrodes very desirable devices.

  14. Electrical Characterization of 3D Au Microelectrodes for Use in Retinal Prostheses

    Directory of Open Access Journals (Sweden)

    Sangmin Lee

    2015-06-01

    Full Text Available In order to provide high-quality visual information to patients who have implanted retinal prosthetic devices, the number of microelectrodes should be large. As the number of microelectrodes is increased, the dimensions of each microelectrode must be decreased, which in turn results in an increased microelectrode interface impedance and decreased injection current dynamic range. In order to improve the trade-off envelope between the number of microelectrodes and the current injection characteristics, a 3D microelectrode structure can be used as an alternative. In this paper, the electrical characteristics of 2D and 3D Au microelectrodes were investigated. In order to examine the effects of the structural difference, 2D and 3D Au microelectrodes with different base areas but similar effective surface areas were fabricated and evaluated. Interface impedances were measured and similar dynamic ranges were obtained for both 2D and 3D Au microelectrodes. These results indicate that more electrodes can be implemented in the same area if 3D designs are used. Furthermore, the 3D Au microelectrodes showed substantially enhanced electrical durability characteristics against over-injected stimulation currents, withstanding electrical currents that are much larger than the limit measured for 2D microelectrodes of similar area. This enhanced electrical durability property of 3D Au microelectrodes is a new finding in microelectrode research, and makes 3D microelectrodes very desirable devices.

  15. Cytokines in bipolar disorder

    DEFF Research Database (Denmark)

    Munkholm, Klaus; Vinberg, Maj; Vedel Kessing, Lars

    2012-01-01

    BACKGROUND: Current research and hypothesis regarding the pathophysiology of bipolar disorder suggests the involvement of immune system dysfunction that is possibly related to disease activity. Our objective was to systematically review evidence of cytokine alterations in bipolar disorder according...... to affective state. METHODS: We conducted a systemtic review of studies measuring endogenous cytokine concentrations in patients with bipolar disorder and a meta-analysis, reporting results according to the PRISMA statement. RESULTS: Thirteen studies were included, comprising 556 bipolar disorder patients...

  16. Nutrition and Bipolar Depression.

    Science.gov (United States)

    Beyer, John L; Payne, Martha E

    2016-03-01

    As with physical conditions, bipolar disorder is likely to be impacted by diet and nutrition. Patients with bipolar disorder have been noted to have relatively unhealthy diets, which may in part be the reason they also have an elevated risk of metabolic syndrome and obesity. An improvement in the quality of the diet should improve a bipolar patient's overall health risk profile, but it may also improve their psychiatric outcomes. New insights into biological dysfunctions that may be present in bipolar disorder have presented new theoretic frameworks for understanding the relationship between diet and bipolar disorder. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. Modeling and Simulation of Microelectrode-Retina Interactions

    Energy Technology Data Exchange (ETDEWEB)

    Beckerman, M

    2002-11-30

    The goal of the retinal prosthesis project is the development of an implantable microelectrode array that can be used to supply visually-driven electrical input to cells in the retina, bypassing nonfunctional rod and cone cells, thereby restoring vision to blind individuals. This goal will be achieved through the study of the fundamentals of electrical engineering, vision research, and biomedical engineering with the aim of acquiring the knowledge needed to engineer a high-density microelectrode-tissue hybrid sensor that will restore vision to millions of blind persons. The modeling and simulation task within this project is intended to address the question how best to stimulate, and communicate with, cells in the retina using implanted microelectrodes.

  18. Glass pipette-carbon fiber microelectrodes for evoked potential recordings

    Directory of Open Access Journals (Sweden)

    Moraes M.F.D.

    1997-01-01

    Full Text Available Current methods for recording field potentials with tungsten electrodes make it virtually impossible to use the same recording electrode also as a lesioning electrode, for example for histological confirmation of the recorded site, because the lesioning procedure usually wears off the tungsten tip. Therefore, the electrode would have to be replaced after each lesioning procedure, which is a very high cost solution to the problem. We present here a low cost, easy to make, high quality glass pipette-carbon fiber microelectrode that shows resistive, signal/noise and electrochemical coupling advantages over tungsten electrodes. Also, currently used carbon fiber microelectrodes often show problems with electrical continuity, especially regarding electrochemical applications using a carbon-powder/resin mixture, with consequent low performance, besides the inconvenience of handling such a mixture. We propose here a new method for manufacturing glass pipette-carbon fiber microelectrodes with several advantages when recording intracerebral field potentials

  19. Combined Reactor and Microelectrode Measurements in Laboratory Grown Biofilms

    DEFF Research Database (Denmark)

    Larsen, Tove; Harremoës, Poul

    1994-01-01

    A combined biofilm reactor-/microelectrode experimental set-up has been constructed, allowing for simultaneous reactor mass balances and measurements of concentration profiles within the biofilm. The system consists of an annular biofilm reactor equipped with an oxygen microelectrode. Experiments...... were carried out with aerobic glucose and starch degrading biofilms. The well described aerobic glucose degradation biofilm system was used to test the combined reactor set-up. Results predicted from known biofilm kinetics were obtained. In the starch degrading biofilm, basic assumptions were tested...... with the microelectrode measurements. It was established, that even with a high molecular weight, non-diffusible substrate, degradation took place in the depths of the biofilm. Intrinsic enzymatic hydrolysis was not limiting and the volumetric removal rate of oxygen was zero order....

  20. Bipolar soft connected, bipolar soft disconnected and bipolar soft compact spaces

    Directory of Open Access Journals (Sweden)

    Muhammad Shabir

    2017-06-01

    Full Text Available Bipolar soft topological spaces are mathematical expressions to estimate interpretation of data frameworks. Bipolar soft theory considers the core features of data granules. Bipolarity is important to distinguish between positive information which is guaranteed to be possible and negative information which is forbidden or surely false. Connectedness and compactness are the most important fundamental topological properties. These properties highlight the main features of topological spaces and distinguish one topology from another. Taking this into account, we explore the bipolar soft connectedness, bipolar soft disconnectedness and bipolar soft compactness properties for bipolar soft topological spaces. Moreover, we introduce the notion of bipolar soft disjoint sets, bipolar soft separation, and bipolar soft hereditary property and study on bipolar soft connected and disconnected spaces. By giving the detailed picture of bipolar soft connected and disconnected spaces we investigate bipolar soft compact spaces and derive some results related to this concept.

  1. Genetics Home Reference: bipolar disorder

    Science.gov (United States)

    ... Email Facebook Twitter Home Health Conditions Bipolar disorder Bipolar disorder Printable PDF Open All Close All Enable Javascript to view the expand/collapse boxes. Description Bipolar disorder is a mental health condition that causes extreme ...

  2. BIPOLAR DISORDER: A REVIEW

    OpenAIRE

    Pathan Dilnawaz N; Ziyaurrahaman A.R; Bhise K.S.

    2010-01-01

    Bipolar disorder (BD) is a severe psychiatric disorder that results in poor global functioning, reduced quality of life and high relapse rates. Research finds that many adults with bipolar disorder identify the onset of symptoms in childhood and adolescence, indicating the importance of early accurate diagnosis and treatment. Accurate diagnosis of mood disorders is critical for treatment to be effective. Distinguishing between major depression and bipolar disorders, especially the depressed p...

  3. Bipolar Disorder in Women

    Directory of Open Access Journals (Sweden)

    Sermin Kesebir

    2013-06-01

    Full Text Available The research on gender's role in bipolar disorders has drawn significant interest recently. The presentation and course of bipolar disorder differs between women and men. Women experience depressive episodes, dysphoric mood, mixed states, rapid cycling and seasonal patterns more often than men. Comorbidity, particularly thyroid disease, migraine, obesity, and anxiety disorders laso occur more frequently in women than men. On the other hand men with bipolar disorder are also more likely than women to have problems with drug or alcohol abuse. The pregnancy and postpartum period is a time of high risk for onset and recurrence of bipolar disorder in women.

  4. Microelectrodes as novel research tools for environmental biofilm studies

    International Nuclear Information System (INIS)

    Yu, T.; Lu, R.; Bishop, L.

    2002-01-01

    Biofilm processes are widely utilized in environmental engineering for biodegradation of contaminated waters, gases and soils. It is important to understand the structure and functions of biofilms. Microelectrodes are novel experimental tools for environmental biofilm studies. The authors reviewed the techniques of oxygen, sulfide, redox potential and pH microelectrode. These microelectrodes have tip diameters of 3 to 20 μm, resulting a high spatial resolution. They enable us directly measure the chemical conditions as results of microbial activities in biofilms. The authors also reported the laboratory and field studies of wastewater biofilms using microelectrode techniques. The results of these studies provided experimental evidence on the stratification of microbial processes and the associated redox potential change in wastewater biofilms: (1) The oxygen penetration depth was only a fraction of the biofilm thickness. This observation, first made under laboratory conditions, has been confirmed under field conditions. (2) The biofilms with both aerobic oxidation and sulfate reduction had a clearly stratified structure. This was evidenced by a sharp decrease of redox potential near the interface between the aerobic zone and the sulfate reduction zone within the biofilm. In this type of biofilms, aerobic oxidation took place only in a shallow layer near the biofilm surface and sulfate reduction occurred in the deeper anoxic zone. (3) The redox potential changed with the shift of primary microbial process in biofilms, indicating that it is possible to use redox potential to help illustrate the structure and functions of biofilms. (author)

  5. Microelectrode measurements of the activity distribution in nitrifying bacterial aggregates

    NARCIS (Netherlands)

    Beer, de D.; Heuvel, van den J.C.; Ottengraf, S.P.P.

    1993-01-01

    Microelectrodes for ammonium, oxygen, nitrate, and pH were used to study nitrifying aggregates grown in a fluidized-bed reactor. Local reactant fluxes and distribution of microbial activity could be detd. from the microprofiles. The interfacial fluxes of the reactants closely reflected the

  6. Integration of Polymer Micro-Electrodes for Bio-Sensing

    DEFF Research Database (Denmark)

    Argyraki, Aikaterini; Larsen, Simon Tylsgaard; Tanzi, Simone

    We present the fabrication of PEDOT and pyrolyzed micro-electrodes for the detection of neurotransmitter exocytosis from single cells. The patterns of the electrodes are defined with photolithography. The micro-electro-fluidic-chips were fabricated by bonding two injection molded TOPAS parts. Pol...

  7. Multi-microelectrode devices for intrafascicular use in peripheral nerve

    NARCIS (Netherlands)

    Rutten, Wim

    1996-01-01

    This minisymposium paper gives an overview of experimental, modeling, design and microfabrication steps which lead towards the University of Twente three-dimensional 128-fold silicon microelectrode device. The device is meant for implantation in peripheral nerve for neuromuscular control purposes

  8. A Platform for Manufacturable Stretchable Micro-electrode Arrays

    NARCIS (Netherlands)

    Khoshfetrat Pakazad, S.; Savov, A.; Braam, S.R.; Dekker, R.

    2012-01-01

    A platform for the batch fabrication of pneumatically actuated Stretchable Micro-Electrode Arrays (SMEAs) by using state-of-the-art micro-fabrication techniques and materials is demonstrated. The proposed fabrication process avoids the problems normally associated with processing of thin film

  9. AFM cantilever with in situ renewable mercury microelectrode

    NARCIS (Netherlands)

    Schön, Peter Manfred; Geerlings, J.; Tas, Niels Roelof; Sarajlic, Edin

    2013-01-01

    We report here first results obtained on a novel, in situ renewable mercury microelectrode integrated into an atomic force microscopy (AFM) cantilever. Our approach is based on a fountain pen probe with appropriate dimensions enabling reversible filling with(nonwetting) mercury under changing the

  10. Lability criteria for metal complexes in micro-electrode voltammetry

    NARCIS (Netherlands)

    Leeuwen, van H.P.; Pinheiro, J.P.

    1999-01-01

    Theoretical expressions are derived for the voltammetric lability criteria of metal complexes in the micro-electrode regime. The treatment includes three limiting situations: (i) the macro-electrode limit, where both the diffusion layer and the dissociation reaction layer are linear; (ii) an

  11. A wideband wireless neural stimulation platform for high-density microelectrode arrays.

    Science.gov (United States)

    Myers, Frank B; Simpson, Jim A; Ghovanloo, Maysam

    2006-01-01

    We describe a system that allows researchers to control an implantable neural microstimulator from a PC via a USB 2.0 interface and a novel dual-carrier wireless link, which provides separate data and power transmission. Our wireless stimulator, Interestim-2B (IS-2B), is a modular device capable of generating controlled-current stimulation pulse trains across 32 sites per module with support for a variety of stimulation schemes (biphasic/monophasic, bipolar/monopolar). We have developed software to generate multi-site stimulation commands for the IS-2B based on streaming data from artificial sensory devices such as cameras and microphones. For PC interfacing, we have developed a USB 2.0 microcontroller-based interface. Data is transmitted using frequency-shift keying (FSK) at 6/12 MHz to achieve a data rate of 3 Mb/s via a pair of rectangular coils. Power is generated using a class-E power amplifier operating at 1 MHz and transmitted via a separate pair of spiral planar coils which are oriented perpendicular to the data coils to minimize cross-coupling. We have successfully demonstrated the operation of the system by applying it as a visual prosthesis. Pulse-frequency modulated stimuli are generated in real-time based on a grayscale image from a webcam. These pulses are projected onto an 11x11 LED matrix that represents a 2D microelectrode array.

  12. Comparative familial aggregation of bipolar disorder in patients with bipolar I and bipolar II disorders.

    Science.gov (United States)

    Parker, Gordon B; Romano, Mia; Graham, Rebecca K; Ricciardi, Tahlia

    2018-05-01

    We sought to quantify the prevalence and differential prevalence of a bipolar disorder among family members of patients with a bipolar I or II disorder. The sample comprised 1165 bipolar and 1041 unipolar patients, with the former then sub-typed as having either a bipolar I or II condition. Family history data was obtained via an online self-report tool. Prevalence of a family member having a bipolar disorder (of either sub-type) was distinctive (36.8%). Patients with a bipolar I disorder reported a slightly higher family history (41.2%) compared to patients with a bipolar II disorder (36.3%), and with both significantly higher than the rate of bipolar disorder in family members of unipolar depressed patients (18.5%). Findings support the view that bipolar disorder is heritable. The comparable rates in the two bipolar sub-types support the positioning of bipolar II disorder as a valid condition with strong genetic underpinnings.

  13. Properties of Bipolar Fuzzy Hypergraphs

    OpenAIRE

    Akram, M.; Dudek, W. A.; Sarwar, S.

    2013-01-01

    In this article, we apply the concept of bipolar fuzzy sets to hypergraphs and investigate some properties of bipolar fuzzy hypergraphs. We introduce the notion of $A-$ tempered bipolar fuzzy hypergraphs and present some of their properties. We also present application examples of bipolar fuzzy hypergraphs.

  14. Bipolar Disorder in Children

    Science.gov (United States)

    2014-01-01

    Although bipolar disorder historically was thought to only occur rarely in children and adolescents, there has been a significant increase in children and adolescents who are receiving this diagnosis more recently (Carlson, 2005). Nonetheless, the applicability of the current bipolar disorder diagnostic criteria for children, particularly preschool children, remains unclear, even though much work has been focused on this area. As a result, more work needs to be done to further the understanding of bipolar symptoms in children. It is hoped that this paper can assist psychologists and other health service providers in gleaning a snapshot of the literature in this area so that they can gain an understanding of the diagnostic criteria and other behaviors that may be relevant and be informed about potential approaches for assessment and treatment with children who meet bipolar disorder criteria. First, the history of bipolar symptoms and current diagnostic criteria will be discussed. Next, assessment strategies that may prove helpful for identifying bipolar disorder will be discussed. Then, treatments that may have relevance to children and their families will be discussed. Finally, conclusions regarding work with children who may have a bipolar disorder diagnosis will be offered. PMID:24800202

  15. Electrochemical measurements on a droplet using gold microelectrodes

    Science.gov (United States)

    Jenabi, Amin; Souri, Asma; Rastkhadiv, Ali

    2016-03-01

    Facile methods of ion recognition are important for the fabrication of electronic tongue systems. In this work, we demonstrate performing pulsed conductometry on microliter electrolyte droplets dropped on gold microelectrodes vapor deposited on soda lime glass slides. A droplet is dropped between two microelectrodes when a voltage waveform from a preprogramed power supply is applied on them. The temporal variation of the electric current passing through the droplet is recorded, digitized and stored. The obtained data are compared with the database formed out of the previous experiences for the classification of the sample electrolytes. It is shown that the shape of the voltage waveform is the important parameter of the process. We devised a method for the optimization of the voltage waveform profile for obtaining the maximum of discriminating information from the recorded current variations.

  16. Electrochemical measurements on a droplet using gold microelectrodes

    International Nuclear Information System (INIS)

    Jenabi, Amin; Souri, Asma; Rastkhadiv, Ali

    2016-01-01

    Facile methods of ion recognition are important for the fabrication of electronic tongue systems. In this work, we demonstrate performing pulsed conductometry on microliter electrolyte droplets dropped on gold microelectrodes vapor deposited on soda lime glass slides. A droplet is dropped between two microelectrodes when a voltage waveform from a preprogramed power supply is applied on them. The temporal variation of the electric current passing through the droplet is recorded, digitized and stored. The obtained data are compared with the database formed out of the previous experiences for the classification of the sample electrolytes. It is shown that the shape of the voltage waveform is the important parameter of the process. We devised a method for the optimization of the voltage waveform profile for obtaining the maximum of discriminating information from the recorded current variations. (paper)

  17. Stretchable microelectrode array using room-temperature liquid alloy interconnects

    International Nuclear Information System (INIS)

    Wei, P; Ziaie, B; Taylor, R; Chung, C; Higgs, G; Pruitt, B L; Ding, Z; Abilez, O J

    2011-01-01

    In this paper, we present a stretchable microelectrode array for studying cell behavior under mechanical strain. The electrode array consists of gold-plated nail-head pins (250 µm tip diameter) or tungsten micro-wires (25.4 µm in diameter) inserted into a polydimethylsiloxane (PDMS) platform (25.4 × 25.4 mm 2 ). Stretchable interconnects to the outside were provided by fusible indium-alloy-filled microchannels. The alloy is liquid at room temperature, thus providing the necessary stretchability and electrical conductivity. The electrode platform can withstand strains of up to 40% and repeated (100 times) strains of up to 35% did not cause any failure in the electrodes or the PDMS substrate. We confirmed biocompatibility of short-term culture, and using the gold pin device, we demonstrated electric field pacing of adult murine heart cells. Further, using the tungsten microelectrode device, we successfully measured depolarizations of differentiated murine heart cells from embryoid body clusters

  18. Comparison of microelectrode sensing configurations for impedimetric cell monitoring

    DEFF Research Database (Denmark)

    Caviglia, Claudia; Heiskanen, Arto; Andresen, Thomas Lars

    2012-01-01

    interdigitated microelectrodes using a versatile custom-made monitoring platform including a 24-channel miniaturized potentiostat. As expected, characterization of bare microelectrodes in buffer and tracking experiments with HeLa cells over 16 hours demonstrate that the coplanar configuration provides a higher......A theoretical and experimental comparison between vertical and coplanar interdigitated sensing configurations for impedimetric cell growth tracking is presented. For the first time, these widely-adopted approaches are quantitatively compared on the same cell populations and on the same 10μm...... sensitivity to cell adhesion and spreading (Cell Index = 1.6 vs. 0.4) albeit at a higher frequency of maximum sensitivity (100kHz vs. 24 kHz)....

  19. Chronic in vivo stability assessment of carbon fiber microelectrode arrays

    Science.gov (United States)

    Patel, Paras R.; Zhang, Huanan; Robbins, Matthew T.; Nofar, Justin B.; Marshall, Shaun P.; Kobylarek, Michael J.; Kozai, Takashi D. Y.; Kotov, Nicholas A.; Chestek, Cynthia A.

    2016-12-01

    Objective. Individual carbon fiber microelectrodes can record unit activity in both acute and semi-chronic (∼1 month) implants. Additionally, new methods have been developed to insert a 16 channel array of carbon fiber microelectrodes. Before assessing the in vivo long-term viability of these arrays, accelerated soak tests were carried out to determine the most stable site coating material. Next, a multi-animal, multi-month, chronic implantation study was carried out with carbon fiber microelectrode arrays and silicon electrodes. Approach. Carbon fibers were first functionalized with one of two different formulations of PEDOT and subjected to accelerated aging in a heated water bath. After determining the best PEDOT formula to use, carbon fiber arrays were chronically implanted in rat motor cortex. Some rodents were also implanted with a single silicon electrode, while others received both. At the end of the study a subset of animals were perfused and the brain tissue sliced. Tissue sections were stained for astrocytes, microglia, and neurons. The local reactive responses were assessed using qualitative and quantitative methods. Main results. Electrophysiology recordings showed the carbon fibers detecting unit activity for at least 3 months with average amplitudes of ∼200 μV. Histology analysis showed the carbon fiber arrays with a minimal to non-existent glial scarring response with no adverse effects on neuronal density. Silicon electrodes showed large glial scarring that impacted neuronal counts. Significance. This study has validated the use of carbon fiber microelectrode arrays as a chronic neural recording technology. These electrodes have demonstrated the ability to detect single units with high amplitude over 3 months, and show the potential to record for even longer periods. In addition, the minimal reactive response should hold stable indefinitely, as any response by the immune system may reach a steady state after 12 weeks.

  20. Pencil lead microelectrode and the application on cell dielectrophoresis

    Energy Technology Data Exchange (ETDEWEB)

    Hsieh, Bo-Chuan; Cheng, Tzong-Jih; Shih, Syuan-He [Department of Bio-Industrial Mechatronics Engineering, National Taiwan University, 136 Chou-Shan Rd., Taipei City 106, Taiwan (China); Chen, Richie L.C., E-mail: rlcchen@ntu.edu.tw [Department of Bio-Industrial Mechatronics Engineering, National Taiwan University, 136 Chou-Shan Rd., Taipei City 106, Taiwan (China)

    2011-11-30

    A microelectrode was fabricated by electrochemical etching of a pencil lead (0.5 mm in diameter) in 1.0 M NaOH aqueous solution. The pencil lead was dipped into the solution and then an ac voltage (3.0 V{sub rms} for 10 min) was imposed against a stainless plate under mild stirring (450 rpm). The electrochemically sharpened pencil tip was about 10 {mu}m in diameter (12 {+-} 3 {mu}m, n = 5), and the lateral part was insulated within a polypropylene micro-pipette tip (2-200 {mu}L volume range). The cyclic voltammograms conducted in 2.0 mM ferricyanide/ferrocyanide buffer solution (pH 7.0) are with low capacitive current and a typical sigmoidal signal of micro-sized electrodes. The microelectrode was used to perform dielectrophoresis of polystyrene latex microbeads (nominal diameter of 3 {mu}m) and human red blood cells. A conducting glass (indium tin oxide coated glass, 40 mm x 40 mm x 1 mm) served as the counter electrode (0.5 mm beneath the microelectrode) to generate the asymmetrical electric field and also as the window for microscopic observation. With the sinusoidal bias voltage (30 V{sub rms}) ranged from 20 Hz to 2 MHz, positive and negative dielectrophoretic phenomena were identified.

  1. What is Bipolar Disorder?

    Science.gov (United States)

    ... down” Have trouble sleeping Think about death or suicide Can someone have bipolar disorder along with other problems? Yes. Sometimes people having very strong mood episodes may have psychotic symptoms. Psychosis affects thoughts ...

  2. Carbon Nanotube-based microelectrodes for enhanced detection of neurotransmitters

    Science.gov (United States)

    Jacobs, Christopher B.

    Fast-scan cyclic voltammetry (FSCV) is one of the common techniques used for rapid measurement of neurotransmitters in vivo. Carbon-fiber microelectrodes (CFMEs) are typically used for neurotransmitter detection because of sub-second measurement capabilities, ability to measure changes in neurotransmitter concentration during neurotransmission, and the small size electrode diameter, which limits the amount of damage caused to tissue. Cylinder CFMEs, typically 50 -- 100 microm long, are commonly used for in vivo experiments because the electrode sensitivity is directly related to the electrode surface area. However the length of the electrode can limit the spatial resolution of neurotransmitter detection, which can restrict experiments in Drosophila and other small model systems. In addition, the electrode sensitivity toward dopamine and serotonin detection drops significantly for measurements at rates faster than 10 Hz, limiting the temporal resolution of CFMEs. While the use of FSCV at carbon-fiber microelectrodes has led to substantial strides in our understanding of neurotransmission, techniques that expand the capabilities of CFMEs are crucial to fully maximize the potential uses of FSCV. This dissertation introduces new methods to integrate carbon nanotubes (CNT) into microelectrodes and discusses the electrochemical enhancements of these CNT-microelectrodes. The electrodes are specifically designed with simple fabrication procedures so that highly specialized equipment is not necessary, and they utilize commercially available materials so that the electrodes could be easily integrated into existing systems. The electrochemical properties of CNT modified CFMEs are characterized using FSCV and the effect of CNT functionalization on these properties is explored in Chapter 2. For example, CFME modification using carboxylic acid functionalized CNTs yield about a 6-fold increase in dopamine oxidation current, but modification with octadecylamine CNTs results in a

  3. Nanoporous gold microelectrode prepared from potential modulated electrochemical alloying–dealloying in ionic liquid

    International Nuclear Information System (INIS)

    Jiang, Junhua; Wang, Xinying; Zhang, Lei

    2013-01-01

    Highlights: • A green chemistry method for producing nanoporous gold microelectrode was studied. • An ionic liquid plating bath was utilized for electrochemical alloying–dealloying. • Nanostructures of gold surface layers can be tuned by modulating potential. • Nanoporous gold microelectrode has high surface area and merit of a microelectrode. • Nitrite oxidation and reduction on nanoporous gold microelectrode were studied. -- Abstract: Nanoporous gold (NPG) microelectrodes with high surface area and open pore network were successfully prepared by applying modulated potential to a polycrystalline Au-disk microelectrode in ionic liquid electrolyte containing ZnCl 2 at elevated temperature. During cathodic process, Zn is electrodeposited and interacted with Au microdisk substrate to form a AuZn alloy phase. During subsequent anodic process, Zn is selectively dissolved from the alloy phase, leading to the formation of a NPG layer which can grow with repetitive potential modulation. Scanning-electron microscope and energy dispersive X-ray microscope measurements show that the NPG microelectrodes possessing nanoporous structures can be tuned via potential modulation, and chemically contain a small amount of Zn whose presence has no obvious influence on electrochemical responses of the electrodes. Steady-state and cyclic voltammetric studies suggest that the NPG microelectrodes have high surface area and keep diffusional properties of a microelectrode. Electrochemical nitrite reduction and oxidation are studied as model reactions to demonstrate potential applications of the NPG microelectrodes in electrocatalysis and electroanalysis. These facts suggest that the potential-modulated electrochemical alloying/dealloying in ionic liquid electrolyte offers a convenient green-chemistry method for the preparation of nanoporous microelectrodes

  4. Bipolar Affective Disorder and Migraine

    Directory of Open Access Journals (Sweden)

    Birk Engmann

    2012-01-01

    Full Text Available This paper consists of a case history and an overview of the relationship, aetiology, and treatment of comorbid bipolar disorder migraine patients. A MEDLINE literature search was used. Terms for the search were bipolar disorder bipolar depression, mania, migraine, mood stabilizer. Bipolar disorder and migraine cooccur at a relatively high rate. Bipolar II patients seem to have a higher risk of comorbid migraine than bipolar I patients have. The literature on the common roots of migraine and bipolar disorder, including both genetic and neuropathological approaches, is broadly discussed. Moreover, bipolar disorder and migraine are often combined with a variety of other affective disorders, and, furthermore, behavioural factors also play a role in the origin and course of the diseases. Approach to treatment options is also difficult. Several papers point out possible remedies, for example, valproate, topiramate, which acts on both diseases, but no first-choice treatments have been agreed upon yet.

  5. Depression and Bipolar Support Alliance

    Science.gov (United States)

    Depression and Bipolar Support Alliance Crisis Hotline Information Coping with a Crisis Suicide Prevention Information Psychiatric Hospitalization ... sign-up Education info, training, events Mood Disorders Depression Bipolar Disorder Anxiety Screening Center Co-occurring Illnesses/ ...

  6. Bipolar Disorder and Cancer

    Directory of Open Access Journals (Sweden)

    Sermin Kesebir

    2012-06-01

    Full Text Available Prevalence studies and studies on causation relations have shown that the relation between psychiatric disorders and chronic physical diseases is neglected. For heterogeneous diseases an increasing number of susceptibility variants are being defined. Alzheimer disease, bipolar disorder, breast and prostate cancer, coronary artery disease, Chron's disease, systemic lupus eritematosus, type 1 and type 2 diabetes mellitus are mentioned together with epigenetic concept. In acrocentric zone of chromosome 13, breast cancer, retinoblastoma, chronic Iymphocytic leukemia genes with B cells, dopamin loci of bipolar disorder are found together. Among bipolar and healthy individuals, an increase risk of breast cancer in female cases has been resported. On the other hand, psychosocial factors that affect stress and response to stress itself may be important variables in prognosis and progression of different cancer types. During the course of many cancer types –especially brain tumors- and during treatment of chemotherapeutic agents, bipolar symptomatology may appear. In this article, it is reviewed with relevant literature that whether an etiological relation between bipolar disorder and cancer exist and how both diseases affect each other's course and treatment.

  7. Long-term neural recordings using MEMS based moveable microelectrodes in the brain

    Directory of Open Access Journals (Sweden)

    Nathan Jackson

    2010-06-01

    Full Text Available One of the critical requirements of the emerging class of neural prosthetic devices is to maintain good quality neural recordings over long time periods. We report here a novel (Micro-ElectroMechanical Systems based technology that can move microelectrodes in the event of deterioration in neural signal to sample a new set of neurons. Microscale electro-thermal actuators are used to controllably move microelectrodes post-implantation in steps of approximately 9 µm. In this study, a total of 12 moveable microelectrode chips were individually implanted in adult rats. Two of the 12 moveable microelectrode chips were not moved over a period of 3 weeks and were treated as control experiments. During the first three weeks of implantation, moving the microelectrodes led to an improvement in the average SNR from 14.61 ± 5.21 dB before movement to 18.13 ± 4.99 dB after movement across all microelectrodes and all days. However, the average RMS values of noise amplitudes were similar at 2.98 ± 1.22 µV and 3.01 ± 1.16 µV before and after microelectrode movement. Beyond three weeks, the primary observed failure mode was biological rejection of the PMMA (dental cement based skull mount resulting in the device loosening and eventually falling from the skull. Additionally, the average SNR for functioning devices beyond three weeks was 11.88 ± 2.02 dB before microelectrode movement and was significantly different (p<0.01 from the average SNR of 13.34 ± 0.919 dB after movement. The results of this study demonstrate that MEMS based technologies can move microelectrodes in rodent brains in long-term experiments resulting in improvements in signal quality. Further improvements in packaging and surgical techniques will potentially enable movable microelectrodes to record cortical neuronal activity in chronic experiments.

  8. Nanostructured gold microelectrodes for extracellular recording from electrogenic cells

    Energy Technology Data Exchange (ETDEWEB)

    Brueggemann, D; Wolfrum, B; Maybeck, V; Mourzina, Y; Jansen, M; Offenhaeusser, A, E-mail: a.offenhaeusser@fz-juelich.de [Institute of Complex Systems and Peter Gruenberg Institute: Bioelectronics (ICS8/PGI8), Forschungszentrum Juelich GmbH, Leo-Brandt-Strasse, 52428 Juelich (Germany); Juelich-Aachen Research Alliance-Fundamental of Future Information Technology (JARA-FIT) (Germany)

    2011-07-01

    We present a new biocompatible nanostructured microelectrode array for extracellular signal recording from electrogenic cells. Microfabrication techniques were combined with a template-assisted approach using nanoporous aluminum oxide to develop gold nanopillar electrodes. The nanopillars were approximately 300-400 nm high and had a diameter of 60 nm. Thus, they yielded a higher surface area of the electrodes resulting in a decreased impedance compared to planar electrodes. The interaction between the large-scale gold nanopillar arrays and cardiac muscle cells (HL-1) was investigated via focused ion beam milling. In the resulting cross-sections we observed a tight coupling between the HL-1 cells and the gold nanostructures. However, the cell membranes did not bend into the cleft between adjacent nanopillars due to the high pillar density. We performed extracellular potential recordings from HL-1 cells with the nanostructured microelectrode arrays. The maximal amplitudes recorded with the nanopillar electrodes were up to 100% higher than those recorded with planar gold electrodes. Increasing the aspect ratio of the gold nanopillars and changing the geometrical layout can further enhance the signal quality in the future.

  9. A Single Platinum Microelectrode for Identifying Soft Drink Samples

    Directory of Open Access Journals (Sweden)

    Lígia Bueno

    2012-01-01

    Full Text Available Cyclic voltammograms recorded with a single platinum microelectrode were used along with a non-supervised pattern recognition, namely, Principal Component Analysis, to conduct a qualitative analysis of sixteen different brands of carbonated soft drinks (Kuat, Soda Antarctica, H2OH!, Sprite 2.0, Guarana Antarctica, Guarana Antarctica Zero, Coca-Cola, Coca-Cola Zero, Coca-Cola Plus, Pepsi, Pepsi Light, Pepsi Twist, Pepsi Twist Light, Pepsi Twist 3, Schin Cola, and Classic Dillar’s. In this analysis, soft drink samples were not subjected to pre-treatment. Good differentiation among all the analysed soft drinks was achieved using the voltammetric data. An analysis of the loading plots shows that the potentials of −0.65 V, −0.4 V, 0.4 V, and 0.750 V facilitated the discrimination process. The electrochemical processes related to this potential are the reduction of hydrogen ions and inhibition of the platinum oxidation by the caffeine adsorption on the electrode surface. Additionally, the single platinum microelectrode was useful for the quality control of the soft drink samples, as it helped to identify the time at which the beverage was opened.

  10. Nanostructured gold microelectrodes for extracellular recording from electrogenic cells.

    Science.gov (United States)

    Brüggemann, D; Wolfrum, B; Maybeck, V; Mourzina, Y; Jansen, M; Offenhäusser, A

    2011-07-01

    We present a new biocompatible nanostructured microelectrode array for extracellular signal recording from electrogenic cells. Microfabrication techniques were combined with a template-assisted approach using nanoporous aluminum oxide to develop gold nanopillar electrodes. The nanopillars were approximately 300-400 nm high and had a diameter of 60 nm. Thus, they yielded a higher surface area of the electrodes resulting in a decreased impedance compared to planar electrodes. The interaction between the large-scale gold nanopillar arrays and cardiac muscle cells (HL-1) was investigated via focused ion beam milling. In the resulting cross-sections we observed a tight coupling between the HL-1 cells and the gold nanostructures. However, the cell membranes did not bend into the cleft between adjacent nanopillars due to the high pillar density. We performed extracellular potential recordings from HL-1 cells with the nanostructured microelectrode arrays. The maximal amplitudes recorded with the nanopillar electrodes were up to 100% higher than those recorded with planar gold electrodes. Increasing the aspect ratio of the gold nanopillars and changing the geometrical layout can further enhance the signal quality in the future.

  11. Types of Bipolar Disorder

    Science.gov (United States)

    ... Events Home Science News Meetings and Events Multimedia Social Media Press Resources Newsletters NIMH News Feeds About Us ... has a lot of money, or has special powers. Someone having psychotic symptoms ... Substance Abuse: People with bipolar disorder may also misuse alcohol ...

  12. Discrete bipolar universal integrals

    Czech Academy of Sciences Publication Activity Database

    Greco, S.; Mesiar, Radko; Rindone, F.

    2014-01-01

    Roč. 252, č. 1 (2014), s. 55-65 ISSN 0165-0114 R&D Projects: GA ČR GAP402/11/0378 Institutional support: RVO:67985556 Keywords : bipolar integral * universal integral * Choquet integral Subject RIV: BA - General Mathematics Impact factor: 1.986, year: 2014 http://library.utia.cas.cz/separaty/2014/E/mesiar-0432224.pdf

  13. El trastorno bipolar

    OpenAIRE

    Freaza Rodríguez, Paula

    2014-01-01

    Se exponen los aspectos más relevantes del trastorno bipolar, entender qué significa este concepto, conocer los tipos que existen, qué otros trastornos suelen aparecer al mismo tiempo y qué tratamientos son los que dan mejores resultados

  14. ON BIPOLAR SINGLE VALUED NEUTROSOPHIC GRAPHS

    OpenAIRE

    Said Broumi; Mohamed Talea; Assia Bakali; Florentin Smarandache

    2016-01-01

    In this article, we combine the concept of bipolar neutrosophic set and graph theory. We introduce the notions of bipolar single valued neutrosophic graphs, strong bipolar single valued neutrosophic graphs, complete bipolar single valued neutrosophic graphs, regular bipolar single valued neutrosophic graphs and investigate some of their related properties.

  15. Application of carbohydrate arrays coupled with mass spectrometry to detect activity of plant-polysaccharide degradative enzymes from the fungus Aspergillus niger.

    Science.gov (United States)

    van Munster, Jolanda M; Thomas, Baptiste; Riese, Michel; Davis, Adrienne L; Gray, Christopher J; Archer, David B; Flitsch, Sabine L

    2017-02-21

    Renewables-based biotechnology depends on enzymes to degrade plant lignocellulose to simple sugars that are converted to fuels or high-value products. Identification and characterization of such lignocellulose degradative enzymes could be fast-tracked by availability of an enzyme activity measurement method that is fast, label-free, uses minimal resources and allows direct identification of generated products. We developed such a method by applying carbohydrate arrays coupled with MALDI-ToF mass spectrometry to identify reaction products of carbohydrate active enzymes (CAZymes) of the filamentous fungus Aspergillus niger. We describe the production and characterization of plant polysaccharide-derived oligosaccharides and their attachment to hydrophobic self-assembling monolayers on a gold target. We verify effectiveness of this array for detecting exo- and endo-acting glycoside hydrolase activity using commercial enzymes, and demonstrate how this platform is suitable for detection of enzyme activity in relevant biological samples, the culture filtrate of A. niger grown on wheat straw. In conclusion, this versatile method is broadly applicable in screening and characterisation of activity of CAZymes, such as fungal enzymes for plant lignocellulose degradation with relevance to biotechnological applications as biofuel production, the food and animal feed industry.

  16. High energy, widely tunable Si-prism-array coupled terahertz-wave parametric oscillator with a deformed pump and optimal crystal location for angle tuning.

    Science.gov (United States)

    Zhang, Ruiliang; Qu, Yanchen; Zhao, Weijiang; Chen, Zhenlei

    2017-03-20

    A high energy, widely tunable Si-prism-array coupled terahertz-wave parametric oscillator (TPO) has been demonstrated by using a deformed pump. The deformed pump is cut from a beam spot of 2 mm in diameter by a 1-mm-wide slit. In comparison with a small pump spot (1-mm diameter), the THz-wave coupling area for the deformed pump is increased without limitation to the low-frequency end of the tuning range. Besides, the crystal location is specially designed to eliminate the alteration of the output position of the pump during angle tuning, so the initially adjusted nearest pumped region to the THz-wave exit surface is maintained throughout the tuning range. The tuning range is 0.58-2.5 THz for the deformed pump, while its low frequency end is limited at approximately 1.2 THz for the undeformed pump with 2 mm diameter. The highest THz-wave output of 2 μJ, which is 2.25 times as large as that from the pump of 1 mm in diameter, is obtained at 1.15 THz under 38 mJ (300  MW/cm2) pumping. The energy conversion efficiency is 5.3×10-5.

  17. Experiments on pumping of liquids using arrays of microelectrodes subjected to travelling wave potentials

    Energy Technology Data Exchange (ETDEWEB)

    Garcia-Sanchez, P; Ramos, A [Dpto. de Electronica y Electromagnetismo, Universidad de Sevilla, 41012 Sevilla (Spain); Green, Nicolas G; Morgan, H [School of Electronics and Computer Science, University of Southampton, SO17 1BJ Southampton (United Kingdom)], E-mail: pablogarcia@us.es

    2008-12-01

    Net fluid flow of electrolytes driven on an array of microelectrodes subjected to a travelling-wave potential is presented. Two sizes of platinum microelectrodes have been studied. In both arrays, at low voltages the liquid flows according to the prediction given by ac electroosmotic theory. At voltages above a threshold the fluid flow is reversed. Measurements of the electrical current when the microelectrode array is pumping the liquid are also reported. Transient behaviours in both electrical current and fluid velocity have been observed.

  18. Experiments on pumping of liquids using arrays of microelectrodes subjected to travelling wave potentials

    International Nuclear Information System (INIS)

    Garcia-Sanchez, P; Ramos, A; Green, Nicolas G; Morgan, H

    2008-01-01

    Net fluid flow of electrolytes driven on an array of microelectrodes subjected to a travelling-wave potential is presented. Two sizes of platinum microelectrodes have been studied. In both arrays, at low voltages the liquid flows according to the prediction given by ac electroosmotic theory. At voltages above a threshold the fluid flow is reversed. Measurements of the electrical current when the microelectrode array is pumping the liquid are also reported. Transient behaviours in both electrical current and fluid velocity have been observed.

  19. Micro-fabrication of three dimensional pyrolysed carbon microelectrodes

    DEFF Research Database (Denmark)

    2017-01-01

    ; soft baking the photoresist layer; performing a full depth exposure with UV light through a first mask; performing a partial depth exposure with UV light through a second mask; wherein the full depth exposure and the partial depth exposure are aligned to ensure that the first and second latent images...... are connected to each other; post-exposure baking the photoresist layer; and developing the microscale patterned resist template as a free-standing structure of cross-linked resist with lateral hanging structures that are supported by vertical support structures at a free height above the substrate. The method...... is characterized by a soft baking temperature below 70 °C. Repetitive coating and partial depth exposure allows for the fabrication of multiple level laterally interconnected structures. Carbonization of the resist template provides truly three-dimensional carbon microelectrode structures....

  20. Thin film microelectrodes for electrochemical detection of neurotransmitters

    DEFF Research Database (Denmark)

    Larsen, Simon Tylsgaard

    An important signaling process in the nervous system is the release of chemical messengers called neurotransmitters from neurons. In this thesis alternative thin film electrode materials for applications targeting electrochemical detection of neurotransmitters in chip devices were evaluated...... and conductive polymer microelectrodes made of Pedot:Pss were also fabricated and used successfully to measure transmitter release from cells. The use of different thin film electrodes for low-noise amperometric measurements of single events of transmitter release from neuronal cells was studied....... For this application a very low current noise is needed together with a large temporal resolution. It was shown, that resistive and capacitive properties of thin film electrode materials are determining their usefulness in low-noise amperometric measurements. An analytical expression for the noise was derived...

  1. A 3-D Microelectrode System for Dielectrophoretic Manipulation of Microparticles

    International Nuclear Information System (INIS)

    Chen, D F; Du, H; Gong, H Q; Li, W H

    2006-01-01

    This paper presents a microfluidic system for manipulation and separation of micron-sized particles based on the combined use of negative dielectrophoresis (DEP) and hydrodynamic forces. A 3-D microelectrode structure (so called paired electrode array) are constructed face to face on the top and bottom sides of the microchannel and driven with highfrequency AC voltage to generate dielectrophoretic gates. Depending on the relative strengths of the two forces, particles such as polystyrene beads or cells carrying by a laminar flow can either penetrate the gate or settle there. This gives rise to certain applications including selectively concentrating particles from the flow, separating particles depending on their sizes or dielectric properties, and automatically positioning particles to selective locations. For this purpose, a microfluidic device consisting of the paired electrode array sitting on the channel has been fabricated using microfabrication techniques. Polystyrene beads were used to study the performance of the device. Experimental results including the concentration and separation of particles are presented

  2. Life expectancy in bipolar disorder

    DEFF Research Database (Denmark)

    Kessing, Lars Vedel; Vradi, Eleni; Andersen, Per Kragh

    2015-01-01

    OBJECTIVE: Life expectancy in patients with bipolar disorder has been reported to be decreased by 11 to 20 years. These calculations are based on data for individuals at the age of 15 years. However, this may be misleading for patients with bipolar disorder in general as most patients have a later...... onset of illness. The aim of the present study was to calculate the remaining life expectancy for patients of different ages with a diagnosis of bipolar disorder. METHODS: Using nationwide registers of all inpatient and outpatient contacts to all psychiatric hospitals in Denmark from 1970 to 2012 we...... remaining life expectancy in bipolar disorder and that of the general population decreased with age, indicating that patients with bipolar disorder start losing life-years during early and mid-adulthood. CONCLUSIONS: Life expectancy in bipolar disorder is decreased substantially, but less so than previously...

  3. [Bipolar disorder in adolescence].

    Science.gov (United States)

    Brunelle, Julie; Milhet, Vanessa; Consoli, Angèle; Cohen, David

    2014-04-01

    Juvenile mania is a concept widely developed but also highly debated since the 1990s. In the heart of this debate, Severe Mood Dysregulation (SMD) and "Temper Dysregulation disorder with Dysphoria" (recently integrated in DSM-5) showed their interest. Actually, the objective is to distinguish two clinical phenotypes in order to avoid confusion between (1) what would raise more of mood dysregulation with chronic manic like symptoms, and (2) bipolar disorder type I with episodic and acute manic episodes. Therapeutic stakes are major. In adolescents, even if DSM adult diagnostic criteria can be used and bipolar disorder type I clearly established, differential diagnostic at onset between acute manic episode and schizophrenia onset remain sometimes difficult to assess. Furthermore, it is crucial to better assess outcome of these adolescents, in terms of morbidity and potential prognosis factors, knowing that a younger age at onset is associated with a poorer outcome according to several adult studies. Therapeutic implications could then be drawn.

  4. Depressive and bipolar disorders

    DEFF Research Database (Denmark)

    Kessing, Lars Vedel; Hansen, Hanne Vibe; Demyttenaere, Koen

    2005-01-01

    of the patients (40-80%) had erroneous views as to the effect of antidepressants. Older patients (over 40 years of age) consistently had a more negative view of the doctor-patient relationship, more erroneous ideas concerning the effect of antidepressants and a more negative view of antidepressants in general....... Moreover, their partners agreed on these negative views. Women had a more negative view of the doctor-patient relationship than men, and patients with a depressive disorder had a more negative view of antidepressants than patients with bipolar disorder. The number of psychiatric hospitalizations......BACKGROUND: There is increasing evidence that attitudes and beliefs are important in predicting adherence to treatment and medication in depressive and bipolar disorders. However, these attitudes have received little study in patients whose disorders were sufficiently severe to require...

  5. Bipolar Plates for PEM Systems

    OpenAIRE

    Lædre, Sigrid

    2016-01-01

    Summary of thesis: The Bipolar Plate (BPP) is an important component in both Proton Exchange Membrane Fuel Cells (PEMFCs) and Proton Exchange Membrane Water Electrolyzers (PEMWEs). Bipolar plate material and processing constitutes for a large fraction of the cost and weight of a PEM cell stack. The main tasks for the bipolar plates in both systems are to separate single cell in a stack, conduct current between single cells and remove heat from active areas. In addition, the BPPs distribu...

  6. [Creativity and bipolar disorder].

    Science.gov (United States)

    Maçkalı, Zeynep; Gülöksüz, Sinan; Oral, Timuçin

    2014-01-01

    The relationship between creativity and bipolar disorder has been an intriguing topic since ancient times. Early studies focused on describing characteristics of creative people. From the last quarter of the twentieth century, researchers began to focus on the relationship between mood disorders and creativity. Initially, the studies were based on biographical texts and the obtained results indicated a relationship between these two concepts. The limitations of the retrospective studies led the researchers to develop systematic investigations into this area. The systematic studies that have focused on artistic creativity have examined both the prevalence of mood disorders and the creative process. In addition, a group of researchers addressed the relationship in terms of affective temperaments. Through the end of the 90's, the scope of creativity was widened and the notion of everyday creativity was proposed. The emergence of this notion led researchers to investigate the associations of the creative process in ordinary (non-artist) individuals. In this review, the descriptions of creativity and creative process are mentioned. Also, the creative process is addressed with regards to bipolar disorder. Then, the relationship between creativity and bipolar disorder are evaluated in terms of aforementioned studies (biographical, systematic, psychobiographical, affective temperaments). In addition, a new model, the "Shared Vulnerability Model" which was developed to explain the relationship between creativity and psychopathology is introduced. Finally, the methodological limitations and the suggestions for resolving these limitations are included.

  7. Reviewing metallic PEMFC bipolar plates

    Energy Technology Data Exchange (ETDEWEB)

    Wang, H.; Turner, J.A. [National Renewable Energy Laboratory, Golden, CO (United States)

    2010-08-15

    A bipolar plate is one of the most important components in a polymer exchange membrane fuel cell (PEMFC) stack and has multiple functions. Metallic bipolar plate candidates have advantages over composite rivals in excellent electrical and thermal conductivity, good mechanical strength, high chemical stability, very wide alloy choices, low cost and, most importantly, existing pathways for high-volume, high-speed mass production. The challenges with metallic bipolar plates are the higher contact resistance and possible corrosion products, which may contaminate the membrane electrode assembly. This review evaluates the candidate metallic and coating materials for bipolar plates and gives the perspective of the research trends. (Abstract Copyright [2010], Wiley Periodicals, Inc.)

  8. A three-dimensional microelectrode array composed of vertically aligned ultra-dense carbon nanotube networks

    Science.gov (United States)

    Nick, C.; Yadav, S.; Joshi, R.; Schneider, J. J.; Thielemann, C.

    2015-07-01

    Electrodes based on carbon nanotubes are a promising approach to manufacture highly sensitive sensors with a low limit of signal detection and a high signal-to-noise ratio. This is achieved by dramatically increasing the electrochemical active surface area without increasing the overall geometrical dimensions. Typically, carbon nanotube electrodes are nearly planar and composed of randomly distributed carbon nanotube networks having a limited surface gain for a specific geometrical surface area. To overcome this limitation, we have introduced vertically aligned carbon nanotube (VACNT) networks as electrodes, which are arranged in a microelectrode pattern of 60 single electrodes. Each microelectrode features a very high aspect ratio of more than 300 and thus a dramatically increased surface area. These microelectrodes composed of VACNT networks display dramatically decreased impedance over the entire frequency range compared to planar microelectrodes caused by the enormous capacity increase. This is experimentally verified by electrochemical impedance spectroscopy and cyclic voltammetry.

  9. Low Frequency Activity of Cortical Networks on Microelectrode Arrays is Differentially Altered by Bicuculline and Carbaryl

    Science.gov (United States)

    Thousands of chemicals need to be characterized for their neurotoxicity potential. Neurons grown on microelectrode arrays (MEAs) are an in vitro model used to screen chemicals for functional effects on neuronal networks. Typically, after removal of low frequency components, effec...

  10. Conductive Polymer Microelectrodes for on-chip measurement of transmitter release from living cells

    DEFF Research Database (Denmark)

    Larsen, Simon Tylsgaard; Matteucci, Marco; Taboryski, Rafael J.

    2012-01-01

    driven cell trapping inside closed chip devices. Conductive polymer microelectrodes were used to measure transmitter release using electrochemical methods such as cyclic voltammetry and constant potential amperometry. By measuring the oxidation current at a cyclic voltammogram, the concentration...

  11. A microfluidic cell culture device with integrated microelectrodes for barrier studies

    DEFF Research Database (Denmark)

    Tan, Hsih-Yin; Dufva, Martin; Kutter, Jörg P.

    We present an eight cell culture microfluidic device fabricated using thiol-ene ‘click’ chemistry with embedded microelectrodes for evaluating barrier properties of human intestinal epithelial cells. The capability of the microelectrodes for trans-epithelial electrical resistance (TEER) measureme......) measurements was demonstrated by using confluent human colorectal epithelial cells (Caco-2) and rat fibroblast (CT 26) cells cultured in the microfluidic device....

  12. Carbon-Ring Microelectrode Arrays for Electrochemical Imaging of Single Cell Exocytosis: Fabrication and Characterization

    Science.gov (United States)

    Lin, Yuqing; Trouillon, Raphaël; Svensson, Maria I.; Keighron, Jacqueline D.; Cans, Ann-Sofie; Ewing, Andrew G.

    2012-01-01

    Fabrication of carbon microelectrode arrays, with up to 15 electrodes in total tips as small as 10 to 50 μm, is presented. The support structures of microelectrodes were obtained by pulling multiple quartz capillaries together to form hollow capillary arrays before carbon deposition. Carbon ring microelectrodes were deposited by pyrolysis of acetylene in the lumen of these quartz capillary arrays. Each carbon deposited array tip was filled with epoxy, followed by beveling of the tip of the array to form a deposited carbon-ring microelectrode array (CRMA). Both the number of the microelectrodes in the array and the tip size are independently tunable. These CRMAs have been characterized using scanning electron microscopy, energy dispersive X-ray spectroscopy, and electrogenerated chemiluminescence. Additionally, the electrochemical properties were investigated with steady-state voltammetry. In order to demonstrate the utility of these fabricated microelectrodes in neurochemistry, CRMAs containing eight microring electrodes were used for electrochemical monitoring of exocytotic events from single PC12 cells. Subcellular temporal heterogeneities in exocytosis (ie. cold spots vs. hot spots) were successfully detected with the CRMAs. PMID:22339586

  13. Scientific attitudes towards bipolar disorders

    Directory of Open Access Journals (Sweden)

    Mohammad-Hossein Biglu

    2014-02-01

    Full Text Available Introduction: Bipolar disorder is a psychiatric condition that is also called manic-depressive disease. It causes unusual changes in mood, energy, activity levels, and the ability to carry out day-to-day tasks. In the present study, 3 sets of data were considered and analyzed: first, all papers categorized under Bipolar Disorders in Science Citation Index Expanded (SCI-E database through 2001-2011; second, papers published by the international journal of Bipolar Disorders indexed in SCI-E during a period of 11 years; and third, all papers distributed by the international journal of Bipolar Disorders indexed in MEDLINE during the period of study. Methods: The SCI-E database was used to extract all papers indexed with the topic of Bipolar Disorders as well as all papers published by The International Journal of Bipolar Disorders. Extraction of data from MEDLINE was restricted to the journals name from setting menu. The Science of Science Tool was used to map the co-authorship network of papers published by The International Journal of Bipolar Disorders through 2009-2011. Results: Analysis of data showed that the majority of publications in the subject area of bipolar disorders indexed in SCI-E were published by The International Journal of Bipolar Disorders. Although journal articles consisted of 59% of the total publication type in SCI-E, 65% of publications distributed by The Journal of Bipolar Disorders were in the form of meetingabstracts. Journal articles consisted of only 23% of the total publications. USA was the leading country regarding sharing data in the field of bipolar disorders followed by England, Canada, and Germany. Conclusion: The editorial policy of The International Journal of Bipolar Disorders has been focused on new themes and new ways of researching in the subject area of bipolar disorder. Regarding the selection of papers for indexing, the SCI-E database selects data more comprehensively than MEDLINE. The number of papers

  14. Epidemiology in Pediatric Bipolar Disorder

    Directory of Open Access Journals (Sweden)

    Caner Mutlu

    2015-12-01

    Full Text Available Childhood and adolescent bipolar disorder diagnosis has been increasing recently. Since studies evaluating attempted suicide rates in children and adolescents have shown bipolarity to be a significant risk factor, diagnosis and treatment of bipolarity has become a very important issue. Since there is a lack of specific diagnostic criteria for especially preadolescent samples and evaluations are made mostly symptomatically, suspicions about false true diagnosis and increased prevalence rates have emerged. This situation leads to controversial data about the prevalence rates of bipolar disorder in children and adolescents. The aim of this article is to review the prevalence of childhood and adolescent bipolar disorder in community, inpatient and outpatient based samples in literature.

  15. Genetics of bipolar disorder

    Directory of Open Access Journals (Sweden)

    Kerner B

    2014-02-01

    Full Text Available Berit Kerner Semel Institute for Neuroscience and Human Behavior, University of California, Los Angeles, Los Angeles, CA, USA Abstract: Bipolar disorder is a common, complex genetic disorder, but the mode of transmission remains to be discovered. Many researchers assume that common genomic variants carry some risk for manifesting the disease. The research community has celebrated the first genome-wide significant associations between common single nucleotide polymorphisms (SNPs and bipolar disorder. Currently, attempts are under way to translate these findings into clinical practice, genetic counseling, and predictive testing. However, some experts remain cautious. After all, common variants explain only a very small percentage of the genetic risk, and functional consequences of the discovered SNPs are inconclusive. Furthermore, the associated SNPs are not disease specific, and the majority of individuals with a “risk” allele are healthy. On the other hand, population-based genome-wide studies in psychiatric disorders have rediscovered rare structural variants and mutations in genes, which were previously known to cause genetic syndromes and monogenic Mendelian disorders. In many Mendelian syndromes, psychiatric symptoms are prevalent. Although these conditions do not fit the classic description of any specific psychiatric disorder, they often show nonspecific psychiatric symptoms that cross diagnostic boundaries, including intellectual disability, behavioral abnormalities, mood disorders, anxiety disorders, attention deficit, impulse control deficit, and psychosis. Although testing for chromosomal disorders and monogenic Mendelian disorders is well established, testing for common variants is still controversial. The standard concept of genetic testing includes at least three broad criteria that need to be fulfilled before new genetic tests should be introduced: analytical validity, clinical validity, and clinical utility. These criteria are

  16. Applying a foil queue micro-electrode in micro-EDM to fabricate a 3D micro-structure

    Science.gov (United States)

    Xu, Bin; Guo, Kang; Wu, Xiao-yu; Lei, Jian-guo; Liang, Xiong; Guo, Deng-ji; Ma, Jiang; Cheng, Rong

    2018-05-01

    Applying a 3D micro-electrode in a micro electrical discharge machining (micro-EDM) can fabricate a 3D micro-structure with an up and down reciprocating method. However, this processing method has some shortcomings, such as a low success rate and a complex process for fabrication of 3D micro-electrodes. By focusing on these shortcomings, this paper proposed a novel 3D micro-EDM process based on the foil queue micro-electrode. Firstly, a 3D micro-electrode was discretized into several foil micro-electrodes and these foil micro-electrodes constituted a foil queue micro-electrode. Then, based on the planned process path, foil micro-electrodes were applied in micro-EDM sequentially and the micro-EDM results of each foil micro-electrode were able to superimpose the 3D micro-structure. However, the step effect will occur on the 3D micro-structure surface, which has an adverse effect on the 3D micro-structure. To tackle this problem, this paper proposes to reduce this adverse effect by rounded corner wear at the end of the foil micro-electrode and studies the impact of machining parameters on rounded corner wear and the step effect on the micro-structure surface. Finally, using a wire cutting voltage of 80 V, a current of 0.5 A and a pulse width modulation ratio of 1:4, the foil queue micro-electrode was fabricated by wire electrical discharge machining. Also, using a pulse width of 100 ns, a pulse interval of 200 ns, a voltage of 100 V and workpiece material of 304# stainless steel, the foil queue micro-electrode was applied in micro-EDM for processing of a 3D micro-structure with hemispherical features, which verified the feasibility of this process.

  17. Early Intervention in Bipolar Disorder.

    Science.gov (United States)

    Vieta, Eduard; Salagre, Estela; Grande, Iria; Carvalho, André F; Fernandes, Brisa S; Berk, Michael; Birmaher, Boris; Tohen, Mauricio; Suppes, Trisha

    2018-05-01

    Bipolar disorder is a recurrent disorder that affects more than 1% of the world population and usually has its onset during youth. Its chronic course is associated with high rates of morbidity and mortality, making bipolar disorder one of the main causes of disability among young and working-age people. The implementation of early intervention strategies may help to change the outcome of the illness and avert potentially irreversible harm to patients with bipolar disorder, as early phases may be more responsive to treatment and may need less aggressive therapies. Early intervention in bipolar disorder is gaining momentum. Current evidence emerging from longitudinal studies indicates that parental early-onset bipolar disorder is the most consistent risk factor for bipolar disorder. Longitudinal studies also indicate that a full-blown manic episode is often preceded by a variety of prodromal symptoms, particularly subsyndromal manic symptoms, therefore supporting the existence of an at-risk state in bipolar disorder that could be targeted through early intervention. There are also identifiable risk factors that influence the course of bipolar disorder, some of them potentially modifiable. Valid biomarkers or diagnosis tools to help clinicians identify individuals at high risk of conversion to bipolar disorder are still lacking, although there are some promising early results. Pending more solid evidence on the best treatment strategy in early phases of bipolar disorder, physicians should carefully weigh the risks and benefits of each intervention. Further studies will provide the evidence needed to finish shaping the concept of early intervention. AJP AT 175 Remembering Our Past As We Envision Our Future April 1925: Interpretations of Manic-Depressive Phases Earl Bond and G.E. Partridge reviewed a number of patients with manic-depressive illness in search of a unifying endo-psychic conflict. They concluded that understanding either phase of illness was "elusive" and

  18. Novel multiple criteria decision making methods based on bipolar neutrosophic sets and bipolar neutrosophic graphs

    OpenAIRE

    Muhammad, Akram; Musavarah, Sarwar

    2016-01-01

    In this research study, we introduce the concept of bipolar neutrosophic graphs. We present the dominating and independent sets of bipolar neutrosophic graphs. We describe novel multiple criteria decision making methods based on bipolar neutrosophic sets and bipolar neutrosophic graphs. We also develop an algorithm for computing domination in bipolar neutrosophic graphs.

  19. Polycrystalline-Diamond MEMS Biosensors Including Neural Microelectrode-Arrays

    Directory of Open Access Journals (Sweden)

    Donna H. Wang

    2011-08-01

    Full Text Available Diamond is a material of interest due to its unique combination of properties, including its chemical inertness and biocompatibility. Polycrystalline diamond (poly-C has been used in experimental biosensors that utilize electrochemical methods and antigen-antibody binding for the detection of biological molecules. Boron-doped poly-C electrodes have been found to be very advantageous for electrochemical applications due to their large potential window, low background current and noise, and low detection limits (as low as 500 fM. The biocompatibility of poly-C is found to be comparable, or superior to, other materials commonly used for implants, such as titanium and 316 stainless steel. We have developed a diamond-based, neural microelectrode-array (MEA, due to the desirability of poly-C as a biosensor. These diamond probes have been used for in vivo electrical recording and in vitro electrochemical detection. Poly-C electrodes have been used for electrical recording of neural activity. In vitro studies indicate that the diamond probe can detect norepinephrine at a 5 nM level. We propose a combination of diamond micro-machining and surface functionalization for manufacturing diamond pathogen-microsensors.

  20. Discovery of Undescribed Brain Tissue Changes Around Implanted Microelectrode Arrays

    Directory of Open Access Journals (Sweden)

    Himanshi Desai

    2012-01-01

    Full Text Available Brain-implantable microelectrode arrays are devicesdesigned to record or electrically stimulate the activity ofneurons in the brain. These devices hold the potential tohelp treat epilepsy, paralysis, blindness, and deafness, andalso provide researchers with insights into a varietyof neural processes, such as memory formation.While these devices have a very promising future,researchers are discovering that their long-termfunctionality is greatly limited by the brain’s naturalimmune response to foreign objects. To improve thefunctional lifetime of these devices, one solution lies infully characterizing and understanding this tissue response.Roles for microglia and astrocytes in this biologicalresponse have been characterized. However, changesto oligodendrocytes, cells that myelinate axons, remainpoorly understood. These cells provide insulationto the axons, which is required for proper neuralfunctioning. Here we report on the changes that occurwith oligodendrocyte processes in tissue aroundmicroelectrode implants in the brain.Six rats were surgically implanted with microelectrodearrays and allowed to recover for 1, 2, or 4 weeks.Subjects were then sacrificed and the brain tissue wasprocessed using our recently developed method, Device-Capture Histology. Immunohistochemistry and confocalmicroscopy was employed to assess the responsearound the device. Results indicated a decrease inoligodendrocyte density and a loss in typical directionalorientation of oligodendrocyte processes in tissue near thedevice. These results suggest alterations in the underlyingneuronal networks around these devices, which maygreatly impact the current functional utility of thesepromising devices.

  1. Investigating brain functional evolution and plasticity using microelectrode array technology.

    Science.gov (United States)

    Napoli, Alessandro; Obeid, Iyad

    2015-10-01

    The aim of this work was to investigate long and short-term plasticity responsible for memory formation in dissociated neuronal networks. In order to address this issue, a set of experiments was designed and implemented in which the microelectrode array electrode grid was divided into four quadrants, two of which were chronically stimulated, every two days for one hour with a stimulation paradigm that varied over time. Overall network and quadrant responses were then analyzed to quantify what level of plasticity took place in the network and how this was due to the stimulation interruption. The results demonstrate that there were no spatial differences in the stimulus-evoked activity within quadrants. Furthermore, the implemented stimulation protocol induced depression effects in the neuronal networks as demonstrated by the consistently lower network activity following stimulation sessions. Finally, the analysis demonstrated that the inhibitory effects of the stimulation decreased over time, thus suggesting a habituation phenomenon. These findings are sufficient to conclude that electrical stimulation is an important tool to interact with dissociated neuronal cultures, but localized stimuli are not enough to drive spatial synaptic potentiation or depression. On the contrary, the ability to modulate synaptic temporal plasticity was a feasible task to achieve by chronic network stimulation. Copyright © 2015 Elsevier Inc. All rights reserved.

  2. Study of the Behavior of the Mercury on Diverse Microelectrodes with Cell of Continuous Flow

    International Nuclear Information System (INIS)

    Cruz Valldeperas, F

    2001-01-01

    A comparative study of six types of microelectrodes in two different support electrolytes was developed using a new analytic technique for analysis of mercury in liquid samples in the ambit of parts by million. For it, a new system of cell of continuous flow and platinum microelectrodes and of platinum with gold film was implemented using volt-amperemetry of anodized spoil with square wave. In a preliminary study, some parameters that characterize the analysis with this new cell were optimized, for example the sample's speed flow and the time of electrodeposition. The calibration curves were made for the different types of microelectrode that were used in an ambit of concentrations of 1-10 ppm. According to the obtained results, the microelectrode that better works is the platinum disk for possessing bigger superficial area exposed to the dissolution, which increases the analite's currents of pick. And as a support electrolyte, potassium tiocianato is recommended because of its effectiveness to solve the analytic sign of the mercury. Studies of answer of the current of mercury regarding the quantity of the placed sample and studies of interferences of the analysis with this type of microelectrode were also carried out. With regard to the study of the quantity of sample, it was obtained that the electrochemical answer of the cell is directly proportional to the concentration of the analite placed in it. In the study of interference, it was found that the copper, lead, and zinc ions affect the analysis of mercury in concentrations of 0.1 ppm and on in the case of the microelectrode of platinum disk. And in case that the same microelectrode is used recovered with gold, it only affects the copper in concentrations over 5 ppm, for what is necessary to take into account a previous treatment of the sample in the event of containing some of the interfering ions [es

  3. Physicochemical properties of peptide-coated microelectrode arrays and their in vitro effects on neuroblast cells

    Energy Technology Data Exchange (ETDEWEB)

    Ghane-Motlagh, Bahareh, E-mail: bahar.ghane@gmail.com [Polystim Neurotechnologies Laboratory, Department of Electrical Engineering, Polytechnique Montreal, QC H3C 3A7 (Canada); Javanbakht, Taraneh; Shoghi, Fatemeh; Wilkinson, Kevin J.; Martel, Richard [Department of Chemistry, University of Montreal, QC H3C 3J7 (Canada); Sawan, Mohamad [Polystim Neurotechnologies Laboratory, Department of Electrical Engineering, Polytechnique Montreal, QC H3C 3A7 (Canada)

    2016-11-01

    Silicon micromachined neural electrode arrays, which act as an interface between bioelectronic devices and neural tissues, play an important role in chronic implants, in vivo. The biological compatibility of chronic microelectrode arrays (MEA) is an essential factor that must be taken into account in their design and fabrication. In order to improve biocompatibility of the MEAs, the surface of the electrodes was coated with polyethylene glycol (PEG) and parylene-C, which are biocompatible polymers. An in vitro study was performed to test the capacity of poly-D-lysine (PDL) to improve neural-cell adhesion and proliferation. Increased proliferation of the neuroblast cells on the microelectrodes was observed in the presence of the PDL. The presence of the peptide on the electrode surface was confirmed using Fourier transform infrared spectroscopy and scanning electron microscopy (SEM). The impedance of the electrodes was not changed significantly before and after PDL deposition. Mouse neuroblast cells were seeded and cultured on the PDL coated and uncoated neural MEAs with different tip-coatings such as platinum, molybdenum, gold, sputtered iridium oxide, and carbon nanotubes. The neuroblast cells grew preferentially on and around peptide coated-microelectrode tips, as compared to the uncoated microelectrodes. - Highlights: • A novel high-density microelectrode array (MEA) for intracortical 3D recording and stimulation was designed and fabricated. • In order to improve neural-cell adhesion and proliferation, the surface of the electrodes was coated with poly-D-lysine (PDL). • An in vitro study was performed to test the capacity of PDL to improve cell adhesion and proliferation. • The neuroblast cells grew preferentially on peptide-coated microelectrode tips compared to the uncoated microelectrodes.

  4. Bipolar pulse forming line

    Science.gov (United States)

    Rhodes, Mark A.

    2008-10-21

    A bipolar pulse forming transmission line module for linear induction accelerators having first, second, third, fourth, and fifth planar conductors which form an interleaved stack with dielectric layers between the conductors. Each conductor has a first end, and a second end adjacent an acceleration axis. The first and second planar conductors are connected to each other at the second ends, the fourth and fifth planar conductors are connected to each other at the second ends, and the first and fifth planar conductors are connected to each other at the first ends via a shorting plate adjacent the first ends. The third planar conductor is electrically connectable to a high voltage source, and an internal switch functions to short a high voltage from the first end of the third planar conductor to the first end of the fourth planar conductor to produce a bipolar pulse at the acceleration axis with a zero net time integral. Improved access to the switch is enabled by an aperture through the shorting plate and the proximity of the aperture to the switch.

  5. Feasibility studies of microelectrode silicon detectors with integrated electronics

    International Nuclear Information System (INIS)

    Dalla Betta, G.-F.; Batignani, G.; Bettarini, S.; Boscardin, M.; Bosisio, L.; Carpinelli, M.; Dittongo, S.; Forti, F.; Giorgi, M.; Gregori, P.; Lusiani, A.; Manghisoni, M.; Pignatel, G.U.; Rama, M.; Ratti, L.; Re, V.; Sandrelli, F.; Speziali, V.; Svelto, F.; Zorzi, N.

    2002-01-01

    We describe our experience on design and fabrication, on high-resistivity silicon substrates, of microstrip detectors and integrated electronics, devoted to high-energy physics experiments and medical/industrial imaging applications. We report on the full program of our collaboration, with particular regards to the tuning of a new fabrication process, allowing for the production of good quality transistors, while keeping under control the basic detector parameters, such as leakage current. Experimental results on JFET and bipolar transistors are presented, and a microstrip detector with an integrated JFET in source-follower configuration is introduced

  6. Asenapine for bipolar disorder

    Directory of Open Access Journals (Sweden)

    Scheidemantel T

    2015-12-01

    Full Text Available Thomas Scheidemantel,1 Irina Korobkova,2 Soham Rej,3,4 Martha Sajatovic1,2 1University Hospitals Case Medical Center, 2Case Western Reserve University School of Medicine, Cleveland, OH, USA; 3Department of Psychiatry, University of Toronto, Toronto, ON, 4Geri PARTy Research Group, Jewish General Hospital, Montreal, QC, Canada Abstract: Asenapine (Saphris® is an atypical antipsychotic drug which has been approved by the US Food and Drug Administration for the treatment of schizophrenia in adults, as well as the treatment of acute manic or mixed episodes of bipolar I in both adult and pediatric populations. Asenapine is a tetracyclic drug with antidopaminergic and antiserotonergic activity with a unique sublingual route of administration. In this review, we examine and summarize the available literature on the safety, efficacy, and tolerability of asenapine in the treatment of bipolar disorder (BD. Data from randomized, double-blind trials comparing asenapine to placebo or olanzapine in the treatment of acute manic or mixed episodes showed asenapine to be an effective monotherapy treatment in clinical settings; asenapine outperformed placebo and showed noninferior performance to olanzapine based on improvement in the Young Mania Rating Scale scores. There are limited data available on the use of asenapine in the treatment of depressive symptoms of BD, or in the maintenance phase of BD. The available data are inconclusive, suggesting the need for more robust data from prospective trials in these clinical domains. The most commonly reported adverse effect associated with use of asenapine is somnolence. However, the somnolence associated with asenapine use did not cause significant rates of discontinuation. While asenapine was associated with weight gain when compared to placebo, it appeared to be modest when compared to other atypical antipsychotics, and its propensity to cause increases in hemoglobin A1c or serum lipid levels appeared to be

  7. Chitosan coated carbon fiber microelectrode for selective in vivo detection of neurotransmitters in live zebrafish embryos

    International Nuclear Information System (INIS)

    Ozel, Rifat Emrah; Wallace, Kenneth N.; Andreescu, Silvana

    2011-01-01

    Graphical abstract: Chitosan coated fiber electrodes are sensitive to serotonin detection while rejecting physiological levels of ascorbic acid interferences. - Abstract: We report the development of a chitosan modified carbon fiber microelectrode for in vivo detection of serotonin. We find that chitosan has the ability to reject physiological levels of ascorbic acid interferences and facilitate selective and sensitive detection of in vivo levels of serotonin, a common catecholamine neurotransmitter. Presence of chitosan on the microelectrode surface was investigated using scanning electron microscopy (SEM) and cyclic voltammetry (CV). The electrode was characterized using differential pulse voltammetry (DPV). A detection limit of 1.6 nM serotonin with a sensitivity of 5.12 nA/μM, a linear range from 2 to 100 nM and a reproducibility of 6.5% for n = 6 electrodes were obtained. Chitosan modified microelectrodes selectively measure serotonin in presence of physiological levels of ascorbic acid. In vivo measurements were performed to measure concentration of serotonin in the live embryonic zebrafish intestine. The sensor quantifies in vivo intestinal levels of serotonin while successfully rejecting ascorbic acid interferences. We demonstrate that chitosan can be used as an effective coating to reject ascorbic acid interferences at carbon fiber microelectrodes, as an alternative to Nafion, and that chitosan modified microelectrodes are reliable tools for in vivo monitoring of changes in neurotransmitter levels.

  8. Acute human brain responses to intracortical microelectrode arrays: Challenges and future prospects

    Directory of Open Access Journals (Sweden)

    Eduardo eFernandez

    2014-07-01

    Full Text Available The emerging field of neuroprosthetics is focused on the development of new therapeutic interventions that will be able to restore some lost neural function by selective electrical stimulation or by harnessing activity recorded from populations of neurons. As more and more patients benefit from these approaches, the interest in neural interfaces has grown significantly and a new generation of penetrating microelectrode arrays are providing unprecedented access to the neurons of the CNS. These microelectrodes have active tip dimensions that are similar in size to neurons and because they penetrate the nervous system, they provide selective access to these cells (within a few microns. However, the very long-term viability of chronically implanted microelectrodes and the capability of recording the same spiking activity over long time periods still remain to be established and confirmed in human studies. Here we review the main responses to acute implantation of microelectrode arrays, and emphasize that it will become essential to control the neural tissue damage induced by these intracortical microelectrodes in order to achieve the high clinical potentials accompanying this technology.

  9. Brain machine interfaces combining microelectrode arrays with nanostructured optical biochemical sensors

    Science.gov (United States)

    Hajj-Hassan, Mohamad; Gonzalez, Timothy; Ghafer-Zadeh, Ebrahim; Chodavarapu, Vamsy; Musallam, Sam; Andrews, Mark

    2009-02-01

    Neural microelectrodes are an important component of neural prosthetic systems which assist paralyzed patients by allowing them to operate computers or robots using their neural activity. These microelectrodes are also used in clinical settings to localize the locus of seizure initiation in epilepsy or to stimulate sub-cortical structures in patients with Parkinson's disease. In neural prosthetic systems, implanted microelectrodes record the electrical potential generated by specific thoughts and relay the signals to algorithms trained to interpret these thoughts. In this paper, we describe novel elongated multi-site neural electrodes that can record electrical signals and specific neural biomarkers and that can reach depths greater than 8mm in the sulcus of non-human primates (monkeys). We hypothesize that additional signals recorded by the multimodal probes will increase the information yield when compared to standard probes that record just electropotentials. We describe integration of optical biochemical sensors with neural microelectrodes. The sensors are made using sol-gel derived xerogel thin films that encapsulate specific biomarker responsive luminophores in their nanostructured pores. The desired neural biomarkers are O2, pH, K+, and Na+ ions. As a prototype, we demonstrate direct-write patterning to create oxygen-responsive xerogel waveguide structures on the neural microelectrodes. The recording of neural biomarkers along with electrical activity could help the development of intelligent and more userfriendly neural prosthesis/brain machine interfaces as well as aid in providing answers to complex brain diseases and disorders.

  10. Chitosan coated carbon fiber microelectrode for selective in vivo detection of neurotransmitters in live zebrafish embryos

    Energy Technology Data Exchange (ETDEWEB)

    Ozel, Rifat Emrah [Department of Chemistry and Biomolecular Science, 8 Clarkson Ave, Potsdam, NY 136995810 (United States); Wallace, Kenneth N. [Department of Biology, Clarkson University, Potsdam, NY 136995810 (United States); Andreescu, Silvana, E-mail: eandrees@clarkson.edu [Department of Chemistry and Biomolecular Science, 8 Clarkson Ave, Potsdam, NY 136995810 (United States)

    2011-06-10

    Graphical abstract: Chitosan coated fiber electrodes are sensitive to serotonin detection while rejecting physiological levels of ascorbic acid interferences. - Abstract: We report the development of a chitosan modified carbon fiber microelectrode for in vivo detection of serotonin. We find that chitosan has the ability to reject physiological levels of ascorbic acid interferences and facilitate selective and sensitive detection of in vivo levels of serotonin, a common catecholamine neurotransmitter. Presence of chitosan on the microelectrode surface was investigated using scanning electron microscopy (SEM) and cyclic voltammetry (CV). The electrode was characterized using differential pulse voltammetry (DPV). A detection limit of 1.6 nM serotonin with a sensitivity of 5.12 nA/{mu}M, a linear range from 2 to 100 nM and a reproducibility of 6.5% for n = 6 electrodes were obtained. Chitosan modified microelectrodes selectively measure serotonin in presence of physiological levels of ascorbic acid. In vivo measurements were performed to measure concentration of serotonin in the live embryonic zebrafish intestine. The sensor quantifies in vivo intestinal levels of serotonin while successfully rejecting ascorbic acid interferences. We demonstrate that chitosan can be used as an effective coating to reject ascorbic acid interferences at carbon fiber microelectrodes, as an alternative to Nafion, and that chitosan modified microelectrodes are reliable tools for in vivo monitoring of changes in neurotransmitter levels.

  11. Modeling suicide in bipolar disorders.

    Science.gov (United States)

    Malhi, Gin S; Outhred, Tim; Das, Pritha; Morris, Grace; Hamilton, Amber; Mannie, Zola

    2018-02-19

    Suicide is a multicausal human behavior, with devastating and immensely distressing consequences. Its prevalence is estimated to be 20-30 times greater in patients with bipolar disorders than in the general population. The burden of suicide and its high prevalence in bipolar disorders make it imperative that our current understanding be improved to facilitate prediction of suicide and its prevention. In this review, we provide a new perspective on the process of suicide in bipolar disorder, in the form of a novel integrated model that is derived from extant knowledge and recent evidence. A literature search of articles on suicide in bipolar disorder was conducted in recognized databases such as Scopus, PubMed, and PsycINFO using the keywords "suicide", "suicide in bipolar disorders", "suicide process", "suicide risk", "neurobiology of suicide" and "suicide models". Bibliographies of identified articles were further scrutinized for papers and book chapters of relevance. Risk factors for suicide in bipolar disorders are well described, and provide a basis for a framework of epigenetic mechanisms, moderated by neurobiological substrates, neurocognitive functioning, and social inferences within the environment. Relevant models and theories include the diathesis-stress model, the bipolar model of suicide and the ideation-to-action models, the interpersonal theory of suicide, the integrated motivational-volitional model, and the three-step theory. Together, these models provide a basis for the generation of an integrated model that illuminates the suicidal process, from ideation to action. Suicide is complex, and it is evident that a multidimensional and integrated approach is required to reduce its prevalence. The proposed model exposes and provides access to components of the suicide process that are potentially measurable and may serve as novel and specific therapeutic targets for interventions in the context of bipolar disorder. Thus, this model is useful not only

  12. Bipolar explosion models for hypernovae

    International Nuclear Information System (INIS)

    Maeda, Keiichi; Nomoto, Ken'ichi

    2003-01-01

    Bipolar explosion models for hypernovae (very energetic supernovae) are presented. These models provide a favorable situation to explain some unexpected features in observations of hypernovae, e.g., high velocity matter dominated by Fe and low velocity matter dominated by O. The overall abundance of these models gives a good fit, at least qualitatively, to abundances in extremely metal-poor stars. We suggest hypernovae be driven by bipolar jets and contribute significantly to the early Galactic chemical evolution

  13. Functional remediation for bipolar disorder

    OpenAIRE

    Martínez-Arán, Anabel, 1971-; Torrent, C.; Solé, B.; Bonnín, C.M.; Rosa, A.R.; Sánchez-Moreno, J.; Vieta i Pascual, Eduard, 1963-

    2014-01-01

    Neurocognitive impairment constitutes a core feature of bipolar illness. The main domains affected are verbal memory, attention, and executive functions. Deficits in these areas as well as difficulties to get functional remission seem to be increased associated with illness progression. Several studies have found a strong relationship between neurocognitive impairment and low functioning in bipolar disorder, as previously reported in other illnesses such as schizophrenia. Cognitive remediatio...

  14. Preparation of metal nanoband microelectrode on poly(dimethylsiloxane) for chip-based amperometric detection

    Energy Technology Data Exchange (ETDEWEB)

    Chen Shaopeng; Wu Jian; Yu Xiaodong [Key Laboratory of Analytical Chemistry for Life Science, Ministry of Education of China, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210093 (China); Xu Jingjuan, E-mail: xujj@nju.edu.cn [Key Laboratory of Analytical Chemistry for Life Science, Ministry of Education of China, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210093 (China); Chen Hongyuan [Key Laboratory of Analytical Chemistry for Life Science, Ministry of Education of China, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210093 (China)

    2010-04-30

    We proposed herein a novel approach for fabricating nanoband microelectrodes for electrochemical detection on an electrophoresis microchip. The metal films were first obtained via region-selective electroless deposition of gold or copper films on PDMS substrates by selective region plasma oxidation through shadow masking. Both metal films show uniform surfaces with the thickness at the level of 100 nm. By casting another PDMS layer on the metal films, the cross section of the sandwich structures can be used as nanoband microelectrodes, which can be renewed just by cutting. These nanoband microelectrodes are successfully used as electrochemical detectors in microchip electrophoresis for the detection of amino acids, proteins and neurotransmitter molecules. Moreover, integrating an Au-Cu double-metal detector with a double-channel electrophoresis system, we can easily distinguish electroactive amino acids from that of non-electroactive amino acids.

  15. A novel method for the fabrication of a high-density carbon nanotube microelectrode array

    Directory of Open Access Journals (Sweden)

    Adam Khalifa

    2015-09-01

    Full Text Available We present a novel method for fabricating a high-density carbon nanotube microelectrode array (MEA chip. Vertically aligned carbon nanotubes (VACNTs were synthesized by microwave plasma-enhanced chemical vapor deposition and thermal chemical vapor deposition. The device was characterized using electrochemical experiments such as cyclic voltammetry, impedance spectroscopy and potential transient measurements. Through-silicon vias (TSVs were fabricated and partially filled with polycrystalline silicon to allow electrical connection from the high-density electrodes to a stimulator microchip. In response to the demand for higher resolution implants, we have developed a unique process to obtain a high-density electrode array by making the microelectrodes smaller in size and designing new ways of routing the electrodes to current sources. Keywords: Microelectrode array, Neural implant, Carbon nanotubes, Through-silicon via interconnects, Microfabrication

  16. Chronic microelectrode investigations of normal human brain physiology using a hybrid depth electrode.

    Science.gov (United States)

    Howard, M A; Volkov, I O; Noh, M D; Granner, M A; Mirsky, R; Garell, P C

    1997-01-01

    Neurosurgeons have unique access to in vivo human brain tissue, and in the course of clinical treatment important scientific advances have been made that further our understanding of normal brain physiology. In the modern era, microelectrode recordings have been used to systematically investigate the cellular properties of lateral temporal cerebral cortex. The current report describes a hybrid depth electrode (HDE) recording technique that was developed to enable neurosurgeons to simultaneously investigate normal cellular physiology during chronic intracranial EEG recordings. The HDE combines microelectrode and EEG recordings sites on a single shaft. Multiple microelectrode recordings are obtained from MRI defined brain sites and single-unit activity is discriminated from these data. To date, over 60 HDEs have been placed in 20 epilepsy surgery patients. Unique physiologic data have been gathered from neurons in numerous brain regions, including amygdala, hippocampus, frontal lobe, insula and Heschl's gyrus. Functional activation studies were carried out without risking patient safety or comfort.

  17. Correlations between histology and neuronal activity recorded by microelectrodes implanted chronically in the cerebral cortex

    Science.gov (United States)

    McCreery, Douglas; Cogan, Stuart; Kane, Sheryl; Pikov, Victor

    2016-06-01

    Objective. To quantify relations between the neuronal activity recorded with chronically-implanted intracortical microelectrodes and the histology of the surrounding tissue, using radial distance from the tip sites and time after array implantation as parameters. Approach. ‘Utah’-type intracortical microelectrode arrays were implanted into cats’ sensorimotor cortex for 275-364 days. The brain tissue around the implants was immuno-stained for the neuronal marker NeuN and for the astrocyte marker GFAP. Pearson’s product-moment correlations were used to quantify the relations between these markers and the amplitudes of the recorded neuronal action potentials (APs) and their signal-to-noise ratios (S/N). Main results. S/N was more stable over post-implant time than was AP amplitude, but its increased correlation with neuronal density after many months indicates ongoing loss of neurons around the microelectrodes. S/N was correlated with neuron density out to at least 140 μm from the microelectrodes, while AP amplitude was correlated with neuron density and GFAP density within ˜80 μm. Correlations between AP amplitude and histology markers (GFAP and NeuN density) were strongest immediately after implantation, while correlation between the neuron density and S/N was strongest near the time the animals were sacrificed. Unlike AP amplitude, there was no significant correlation between S/N and density of GFAP around the tip sites. Significance. Our findings indicate an evolving interaction between changes in the tissue surrounding the microelectrodes and the microelectrode’s electrical properties. Ongoing loss of neurons around recording microelectrodes, and the interactions between their delayed electrical deterioration and early tissue scarring around the tips appear to pose the greatest threats to the microelectrodes’ long-term functionality.

  18. Strain response of stretchable micro-electrodes: Controlling sensitivity with serpentine designs and encapsulation

    International Nuclear Information System (INIS)

    Gutruf, Philipp; Walia, Sumeet; Nur Ali, Md; Sriram, Sharath; Bhaskaran, Madhu

    2014-01-01

    The functionality of flexible electronics relies on stable performance of thin film micro-electrodes. This letter investigates the behavior of gold thin films on polyimide, a prevalent combination in flexible devices. The dynamic behavior of gold micro-electrodes has been studied by subjecting them to stress while monitoring their resistance in situ. The shape of the electrodes was systematically varied to examine resistive strain sensitivity, while an additional encapsulation was applied to characterize multilayer behavior. The realized designs show remarkable tolerance to repetitive strain, demonstrating that curvature and encapsulation are excellent approaches for minimizing resistive strain sensitivity to enable durable flexible electronics

  19. Surface-modified microelectrode array with flake nanostructure for neural recording and stimulation

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ju-Hyun; Choi, Yang-Kyu [Nano-Oriented Bio-Electronics Lab, Department of Electrical Engineering, College of Information Science and Technology, KAIST, Daejeon 305-701 (Korea, Republic of); Kang, Gyumin; Nam, Yoonkey, E-mail: ynam@kaist.ac.kr, E-mail: ykchoi@ee.kaist.ac.kr [Department of Bio and Brain Engineering, KAIST, KAIST Institute for Nano-Century, Daejeon 305-701 (Korea, Republic of)

    2010-02-26

    A novel microelectrode modification method is reported for neural electrode engineering with a flake nanostructure (nanoflake). The nanoflake-modified electrodes are fabricated by combining conventional lithography and electrochemical deposition to implement a microelectrode array (MEA) on a glass substrate. The unique geometrical properties of nanoflake sharp tips and valleys are studied by optical, electrochemical and electrical methods in order to verify the advantages of using nanoflakes for neural recording devices. The in vitro recording and stimulation of cultured hippocampal neurons are demonstrated on the nanoflake-modified MEA and the clear action potentials are observed due to the nanoflake impedance reduction effect.

  20. Fast prototyping of conducting polymer microelectrodes using resistance-controlled high precision drilling

    DEFF Research Database (Denmark)

    Kafka, Jan Robert; Geschke, Oliver; Skaarup, Steen

    2011-01-01

    We present a straightforward method for fast prototyping of microelectrode arrays in the highly conductive polymer poly(3,4-ethylenedioxythiophene) (PEDOT). Microelectrode arrays were produced by electrical resistance-controlled microdrilling through an insulating polymer layer (TOPAS® 5013...... approach the steady state currents predicted from modeling, but at a much slower rate than expected. This is shown to be caused by the use of electroactive PEDOT electrodes. Subtraction of the latter contribution gives approach to steady state currents within a few seconds, which is in very good agreement...

  1. Microelectrode for energy and current control of nanotip field electron emitters

    International Nuclear Information System (INIS)

    Lüneburg, S.; Müller, M.; Paarmann, A.; Ernstorfer, R.

    2013-01-01

    Emerging experiments and applications in electron microscopy, holography, and diffraction benefit from miniaturized electron guns for compact experimental setups. We present a highly compact microelectrode integrated field emitter that consists of a tungsten nanotip coated with a few micrometers thick polyimide film followed by a several nanometers thick gold film, both positioned behind the exposed emitter apex by approximately 10–30 μm. The control of the electric field strength at the nanometer scale tip apex allows suppression, extraction, and energy tuning of field-emitted electrons. The performance of the microelectrode is demonstrated experimentally and supported by numerical simulations

  2. Quetiapine monotherapy for bipolar depression

    Directory of Open Access Journals (Sweden)

    Michael E Thase

    2008-03-01

    Full Text Available Michael E ThaseDepartments of Psychiatry, University of Pennsylvania School of Medicine, Philadelphia, PA, USA; the Philadelphia Veterans Affairs Medical Center, Philadelphia, PA, USA; and the University of Pittsburgh Medical Center, Pittsburgh, PA, USAAbstract: Bipolar depression is more common, disabling, and difficult-to-treat than the manic and hypomanic phases that define bipolar disorder. Unlike the treatment of so-called “unipolar” depressions, antidepressants generally are not indicated as monotherapies for bipolar depressions and recent studies suggest that - even when used in combination with traditional mood stabilizers – antidepressants may have questionable value for bipolar depression. The current practice is that mood stabilizers are initiated first as monotherapies; however, the antidepressant efficacy of lithium and valproate is modest at best. Within this context the role of atypical antipsychotics is being evaluated. The combination of olanzapine and the antidepressant fluoxetine was the first treatment to receive regulatory approval in the US specifically for bipolar I depression. Quetiapine was the second medication to be approved for this indication, largely as the result of two pivotal trials known by the acronyms of BOLDER (BipOLar DEpRession I and II. Both studies demonstrated that two doses of quetiapine (300 mg and 600 mg given once daily at bedtime were significantly more effective than placebo, with no increased risk of patients switching into mania. Pooling the two studies, quetiapine was effective for both bipolar I and bipolar II depressions and for patients with (and without a history of rapid cycling. The two doses were comparably effective in both studies. Although the efficacy of quetiapine monotherapy has been established, much additional research is necessary. Further studies are needed to more fully investigate dose-response relationships and comparing quetiapine monotherapy to other mood stabilizers

  3. Integrated neurobiology of bipolar disorder

    Directory of Open Access Journals (Sweden)

    Vladimir eMaletic

    2014-08-01

    Full Text Available From a neurobiological perspective there is no such thing as bipolar disorder. Rather, it is almost certainly the case that many somewhat similar, but subtly different, pathological conditions produce a disease state that we currently diagnose as bipolarity. This heterogeneity—reflected in the lack of synergy between our current diagnostic schema and our rapidly advancing scientific understanding of the condition—limits attempts to articulate an integrated perspective on bipolar disorder. However, despite these challenges, scientific findings in recent years are beginning to offer a provisional unified field theory of the disease. This theory sees bipolar disorder as a suite of related neurodevelopmental conditions with interconnected functional abnormalities that often appear early in life and worsen over time. In addition to accelerated loss of volume in brain areas known to be essential for mood regulation and cognitive function, consistent findings have emerged at a cellular level, providing evidence that bipolar disorder is reliably associated with dysregulation of glial-neuronal interactions. Among these glial elements are microglia—the brain’s primary immune elements, which appear to be overactive in the context of bipolarity. Multiple studies now indicate that inflammation is also increased in the periphery of the body in both the depressive and manic phases of the illness, with at least some return to normality in the euthymic state. These findings are consistent with changes in the HPA axis, which are known to drive inflammatory activation. In summary, the very fact that no single gene, pathway or brain abnormality is likely to ever account for the condition is itself an extremely important first step in better articulating an integrated perspective on both its ontological status and pathogenesis. Whether this perspective will translate into the discovery of innumerable more homogeneous forms of bipolarity is one of the great

  4. Bipolar Disorder and Alcoholism: Are They Related?

    Science.gov (United States)

    ... Are they related? Is there a connection between bipolar disorder and alcoholism? Answers from Daniel K. Hall-Flavin, M.D. Bipolar disorder and alcoholism often occur together. Although the association ...

  5. Bipolar outflow in B335

    International Nuclear Information System (INIS)

    Hirano, N.; Kameya, O.; Nakayama, M.; Takakubo, K.

    1988-01-01

    The high-velocity (C-12)O (J = 1-0) emission in B335 with a high angular resolution of 16 arcsec has been mapped. The high-velocity emission shows distinct bipolar pattern centered at IRAS 19345+0727, toward which a strong high-velocity (C-12)O emission has been detected. The bipolar lobes delineate remarkable collimation toward the IRAS source, indicating that the flow is focused within 0.02 pc of the driving source. Each lobe is accompanied by significant wing emission with the opposite velocity shift, which clearly shows the association with IRAS 19345+0727. This feature is well explained as a bipolar flow the axis of which is nearly perpendicular to the line of sight. There is no evidence of another evolved bipolar flow which does not associate with any dense core as previously suggested. This suggests that B335 is a site of very recent star formation, containing a single bipolar flow with an age of about 30,000 yr. 15 references

  6. Exercising control over bipolar disorder.

    Science.gov (United States)

    Malhi, Gin S; Byrow, Yulisha

    2016-11-01

    Following extensive research exercise has emerged as an effective treatment for major depressive disorder, and it is now a recognised therapy alongside other interventions. In contrast, there is a paucity of research examining the therapeutic effects of exercise for those with bipolar disorder. Given that dysfunctional reward processing is central to bipolar disorder, research suggests that exercise can perhaps be framed as a reward-related event that may have the potential to precipitate a manic episode. The behavioural activation system (BAS) is a neurobehavioural system that is associated with responding to reward and provides an appropriate framework to theoretically examine and better understand the effects of exercise treatment on bipolar disorder. This article discusses recent research findings and provides an overview of the extant literature related to the neurobiological underpinnings of BAS and exercise as they relate to bipolar disorder. This is important clinically because depending on mood state in bipolar disorder, we postulate that exercise could be either beneficial or deleterious with positive or negative effects on the illness. Clearly, this complicates the evaluation of exercise as a potential treatment in terms of identifying its optimal characteristics in this population. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  7. Late Onset Bipolar Disorder: Case Report

    OpenAIRE

    Filipa Araújo; Adriana Horta

    2016-01-01

    Background: Bipolar disorder affects approximately 1% of the population, with diagnosis often being made during late adolescence and early adulthood, and only rarely (0.1%) in the elderly. Late onset bipolar disorder in the elderly has a impact on the nature and course of bipolar disorder. Aims: The authors report a case of bipolar disorder emerging in late life  (76years old) with no cleary identified organic cause. Conclusion: This case highlights the importance of a broad different...

  8. Imunologia do transtorno bipolar Immunology of bipolar disorder

    Directory of Open Access Journals (Sweden)

    Izabela Guimarães Barbosa

    2009-01-01

    Full Text Available OBJETIVO: Pesquisas recentes têm implicado fatores imunes na patogênese de diversos transtornos neuropsiquiátricos. O objetivo do presente trabalho é revisar os trabalhos que investigaram a associação entre transtorno bipolar e alterações em parâmetros imunes. MÉTODOS: Artigos que incluíam as palavras-chave: "bipolar disorder", "mania", "immunology", "cytokines", "chemokines", "interleukins", "interferon" e "tumor necrosis factor" foram selecionados em uma revisão sistemática da literatura. As bases de dados avaliadas foram MedLine e Scopus, entre os anos de 1980 e 2008. RESULTADOS: Foram identificados 28 trabalhos que estudaram alterações imunes em pacientes com transtorno bipolar. Seis artigos investigaram genes relacionados à resposta imune; cinco, autoanticorpos; quatro, populações leucocitárias; 13, citocinas e/ou moléculas relacionadas à resposta imune e seis, leucócitos de pacientes in vitro. CONCLUSÕES: Embora haja evidências na literatura correlacionando o transtorno bipolar a alterações imunes, os dados não são conclusivos. O transtorno bipolar parece estar associado a níveis mais elevados de autoanticorpos circulantes, assim como à tendência à ativação imune com produção de citocinas pró-inflamatórias e redução de parâmetros anti-inflamatórios.OBJECTIVE: Emerging research has implicated immune factors in the pathogenesis of a variety of neuropsychiatric disorders. The objective of the present paper is to review the studies that investigated the association between bipolar disorder and immune parameters. METHODS: Papers that included the keywords "bipolar to disorder", "mania", "immunology", "cytokines", "chemokines", "interleukins", "interferon" and "tumor necrosis factor" were selected in a systematic review of the literature. The evaluated databases were MedLine and Scopus in the period between 1980 and 2008. RESULTS: Twenty eight works were found. Six studies investigated immune response

  9. Selective wetting-induced micro-electrode patterning for flexible micro-supercapacitors.

    Science.gov (United States)

    Kim, Sung-Kon; Koo, Hyung-Jun; Lee, Aeri; Braun, Paul V

    2014-08-13

    Selective wetting-induced micro-electrode patterning is used to fabricate flexible micro-supercapacitors (mSCs). The resulting mSCs exhibit high performance, mechanical stability, stable cycle life, and hold great promise for facile integration into flexible devices requiring on-chip energy storage. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Intraneural stimulation using wire-microelectrode arrays: analysis of force steps in recruitment curves

    NARCIS (Netherlands)

    Smit, J.P.A.; Rutten, Wim; Boom, H.B.K.

    1996-01-01

    In acute experiments on six Wistar rats, a wire-microelectrode array was inserted into the common peroneal nerve. A 5-channel array and a 24-channel array were available. Each electrode in the array was used to generate a twitch contraction force recruitment curve for the extensor digitorum longus

  11. Piezoelectric translator. A simple and inexpensive device to move microelectrodes and micropipettes small distances rapidly.

    Science.gov (United States)

    Lederer, W J

    1983-09-01

    A device is described that is capable of rapidly moving microelectrodes and micropipettes over distances up to 15 mu. This piezoelectric transLator uses the diaphragm from virtually any available piezoelectric buzzer in combination with simple physical support and drive electronics. All of the necessary details for the construction of this small device are presented. Each finished unit is about 2 cm long with a diameter of 2 cm and can be readily adapted to existing manipulators. The translator has been found useful in aiding the independent penetration by one or more microelectrodes of single cells or of more complicated multicellular preparations (including those that lie behind a connective tissue layer). This new device offers fine control of microelectrode motion that cannot be obtained by the other methods used to aid microelectrode and micropipette penetration of cell membranes (e.g. capacitance overcompensation--"ringing in"' or "tickling"--or tapping the manipulator base). Finally, the device described in this paper is extremely simple and inexpensive to build.

  12. Performance Improvement by Layout Designs of Conductive Polymer Microelectrode Based Impedimetric Biosensors

    DEFF Research Database (Denmark)

    Rosati, Giulio; Daprà, Johannes; Cherré, Solène

    2014-01-01

    In this work we present a theoretical, computational, and experimental evaluation of the performance of an impedimetric biosensor based on interdigitated conductive polymer (PEDOT:TsO) microelectrodes in a microfluidic system. The influence of the geometry of the electrodes and microchannels on t...

  13. All-diamond functional surface micro-electrode arrays for brain-slice neural analysis

    Czech Academy of Sciences Publication Activity Database

    Vahidpour, F.; Curley, L.; Biró, I.; McDonald, M.; Croux, D.; Pobedinskas, P.; Haenen, K.; Giugliano, M.; Vlčková Živcová, Zuzana; Kavan, Ladislav; Nesládek, M.

    2017-01-01

    Roč. 214, č. 2 (2017), č. článku 1532347. ISSN 1862-6300 R&D Projects: GA ČR GA13-31783S Institutional support: RVO:61388955 Keywords : impedance spectroscopy * microelectrode arrays * surface termination Subject RIV: CG - Electrochemistry OBOR OECD: Electrochemistry (dry cells, batteries, fuel cells, corrosion metals, electrolysis) Impact factor: 1.775, year: 2016

  14. Investigation of parameters controlling the dielectrophoretic assembly of carbon nanotubes on microelectrodes

    DEFF Research Database (Denmark)

    Dimaki, Maria; Bøggild, Peter

    2008-01-01

    Networks of single-walled carbon nanotubes were assembled onto microelectrodes by dielectrophoresis. The dependence of the obtained networks on several assembly parameters such as bias voltage, field application time, frequency, electrode geometry and the nanotube solvent were investigated both s...

  15. A nanoporous alumina microelectrode array for functional cell–chip coupling

    International Nuclear Information System (INIS)

    Wesche, Manuel; Hüske, Martin; Yakushenko, Alexey; Brüggemann, Dorothea; Mayer, Dirk; Offenhäusser, Andreas; Wolfrum, Bernhard

    2012-01-01

    The design of electrode interfaces has a strong impact on cell-based bioelectronic applications. We present a new type of microelectrode array chip featuring a nanoporous alumina interface. The chip is fabricated in a combination of top-down and bottom-up processes using state-of-the-art clean room technology and self-assembled generation of nanopores by aluminum anodization. The electrode characteristics are investigated in phosphate buffered saline as well as under cell culture conditions. We show that the modified microelectrodes exhibit decreased impedance compared to planar microelectrodes, which is caused by a nanostructuring effect of the underlying gold during anodization. The stability and biocompatibility of the device are demonstrated by measuring action potentials from cardiomyocyte-like cells growing on top of the chip. Cross sections of the cell–surface interface reveal that the cell membrane seals the nanoporous alumina layer without bending into the sub-50 nm apertures. The nanoporous microelectrode array device may be used as a platform for combining extracellular recording of cell activity with stimulating topographical cues. (paper)

  16. Characterization of Early Cortical Neural Network Development in Multiwell Microelectrode Array Plates

    Science.gov (United States)

    We examined the development of neural network activity using microelectrode array (MEA) recordings made in multi-well MEA plates (mwMEAs) over the first 12 days in vitro (DIV). In primary cortical cultures made from postnatal rats, action potential spiking activity was essentiall...

  17. Impedance measurements on Au microelectrodes using controlled atmosphere high temperature scanning probe microscope

    DEFF Research Database (Denmark)

    Wu, Yuehua; Hansen, Karin Vels; Jacobsen, Torben

    2011-01-01

    High temperature impedance measurements on Au microelectrodes deposited on polished yttria stabilized zirconia (YSZ) pellets were demonstrated using a newly designed controlled atmosphere high temperature scanning probe microscope (CAHT-SPM). Probes based on Pt0.8Ir0.2 were fabricated and employed...

  18. Mathematical models of bipolar disorder

    Science.gov (United States)

    Daugherty, Darryl; Roque-Urrea, Tairi; Urrea-Roque, John; Troyer, Jessica; Wirkus, Stephen; Porter, Mason A.

    2009-07-01

    We use limit cycle oscillators to model bipolar II disorder, which is characterized by alternating hypomanic and depressive episodes and afflicts about 1% of the United States adult population. We consider two non-linear oscillator models of a single bipolar patient. In both frameworks, we begin with an untreated individual and examine the mathematical effects and resulting biological consequences of treatment. We also briefly consider the dynamics of interacting bipolar II individuals using weakly-coupled, weakly-damped harmonic oscillators. We discuss how the proposed models can be used as a framework for refined models that incorporate additional biological data. We conclude with a discussion of possible generalizations of our work, as there are several biologically-motivated extensions that can be readily incorporated into the series of models presented here.

  19. Is bipolar always bipolar? Understanding the controversy on bipolar disorder in children

    Science.gov (United States)

    Grimmer, Yvonne; Hohmann, Sarah

    2014-01-01

    Dramatically increasing prevalence rates of bipolar disorder in children and adolescents in the United States have provoked controversy regarding the boundaries of manic symptoms in child and adolescent psychiatry. The serious impact of this ongoing debate on the treatment of affected children is reflected in the concomitant increase in prescription rates for antipsychotic medication. A key question in the debate is whether this increase in bipolar disorder in children and adolescents is based on a better detection of early-onset bipolar disorder—which can present differently in children and adolescents—or whether it is caused by an incorrect assignment of symptoms which overlap with other widely known disorders. So far, most findings suggest that the suspected symptoms, in particular chronic, non-episodic irritability (a mood symptom presenting with easy annoyance, temper tantrums and anger) do not constitute a developmental presentation of childhood bipolar disorder. Additional research based on prospective, longitudinal studies is needed to further clarify the developmental trajectories of bipolar disorder and the diagnostic status of chronic, non-episodic irritability. PMID:25580265

  20. Implications of chronic daily anti-oxidant administration on the inflammatory response to intracortical microelectrodes

    Science.gov (United States)

    Potter-Baker, Kelsey A.; Stewart, Wade G.; Tomaszewski, William H.; Wong, Chun T.; Meador, William D.; Ziats, Nicholas P.; Capadona, Jeffrey R.

    2015-08-01

    Objective. Oxidative stress events have been implicated to occur and facilitate multiple failure modes of intracortical microelectrodes. The goal of the present study was to evaluate the ability of a sustained concentration of an anti-oxidant and to reduce oxidative stress-mediated neurodegeneration for the application of intracortical microelectrodes. Approach. Non-functional microelectrodes were implanted into the cortex of male Sprague Dawley rats for up to sixteen weeks. Half of the animals received a daily intraperitoneal injection of the natural anti-oxidant resveratrol, at 30 mg kg-1. The study was designed to investigate the biodistribution of the resveratrol, and the effects on neuroinflammation/neuroprotection following device implantation. Main results. Daily maintenance of a sustained range of resveratrol throughout the implantation period resulted in fewer degenerating neurons in comparison to control animals at both two and sixteen weeks post implantation. Initial and chronic improvements in neuronal viability in resveratrol-dosed animals were correlated with significant reductions in local superoxide anion accumulation around the implanted device at two weeks after implantation. Controls, receiving only saline injections, were also found to have reduced amounts of accumulated superoxide anion locally and less neurodegeneration than controls at sixteen weeks post-implantation. Despite observed benefits, thread-like adhesions were found between the liver and diaphragm in resveratrol-dosed animals. Significance. Overall, our chronic daily anti-oxidant dosing scheme resulted in improvements in neuronal viability surrounding implanted microelectrodes, which could result in improved device performance. However, due to the discovery of thread-like adhesions, further work is still required to optimize a chronic anti-oxidant dosing regime for the application of intracortical microelectrodes.

  1. Bipolar dislocation of the clavicle

    Directory of Open Access Journals (Sweden)

    Wei Jiang

    2012-01-01

    Full Text Available Bipolar dislocation of the clavicle at acromioclavicular and sternoclavicular joint is an uncommon traumatic injury. The conservative treatments adopted in the past is associated with redislocation dysfunction and deformity. A 41 years old lady with bipolar dislocation of right shoulder is treated surgically by open reduction and internal fixation by oblique T-plate at sternoclavicular joint and Kirschner wire stabilization at acromioclavicular joint. The patient showed satisfactory recovery with full range of motion of the right shoulder and normal muscular strength. The case reported in view of rarity and at 2 years followup.

  2. Transcultural aspects of bipolar disorder

    OpenAIRE

    Sanches, Marsal; Jorge, Miguel Roberto

    2004-01-01

    Considerando-se que existem diferenças importantes na maneira como as emoções são vivenciadas e expressas em diferentes culturas, a apresentação e o manejo do transtorno afetivo bipolar sofrem influência de fatores culturais. O presente artigo realiza uma breve revisão da evidência referente aos aspectos transculturais do transtorno bipolar.Cultural variations in the expression of emotions have been described. Consequently, there are cross-cultural influences on the diagnosis and management o...

  3. Electronic monitoring in bipolar disorder.

    Science.gov (United States)

    Faurholt-Jepsen, Maria

    2018-03-01

    Major reasons for the insufficient effects of current treatment options in bipolar disorder include delayed intervention for prodromal depressive and manic symptoms and decreased adherence to psychopharmacological treatment. The reliance on subjective information and clinical evaluations when diagnosing and assessing the severity of depressive and manic symptoms calls for less biased and more objective markers. By using electronic devices, fine-grained data on complex psychopathological aspects of bipolar disorder can be evaluated unobtrusively over the long term. Moreover, electronic data could possibly represent candidate markers of diagnosis and illness activity in bipolar disorder and allow for early and individualized intervention for prodromal symptoms outside clinical settings. 
The present dissertation concerns the use of electronic monitoring as a marker and treatment intervention in bipolar disorder and investigated the scientific literature and body of evidence within the area, which includes ten original study reports and two systematic reviews, one of which included a meta-analysis, conducted by the author of the dissertation. 
Taken together, the literature presented in this dissertation illustrates that 1) smartphone-based electronic self-monitoring of mood seems to reflect clinically assessed depressive and manic symptoms and enables the long-term characterization of mood

instability in bipolar disorder; 2) preliminary results suggest that smartphone-based automatically generated data (e.g. the number of text messages sent/day; the number of incoming and outgoing calls/day; the number of changes in cell tower IDs/day; and voice features) seem to reflect clinically assessed depressive and manic symptoms in bipolar disorder; 3) smartphone-based electronic self-monitoring had no effects on the severity of depressive and manic symptoms in bipolar disorder, according to a randomized controlled trial; and 4) electronic monitoring of psychomotor

  4. Social support and bipolar disorder

    Directory of Open Access Journals (Sweden)

    Paula Mendonça Studart

    2015-08-01

    Full Text Available Background Bipolar disorder is a chronic condition that affects the functioning of its carriers in many different ways, even when treated properly. Therefore, it’s also important to identify the psychosocial aspects that could contribute to an improvement of this population’s quality of life.Objective Carry out a literature review on the role of social support in cases of bipolar disorder.Method A research on the following online databases PubMed, Lilacs and SciELO was conducted by using the keywords “social support” or “social networks” and “mood disorders” or “bipolar disorder” or “affective disorder,” with no defined timeline.Results Only 13 studies concerning the topic of social support and BD were found in the search for related articles. Generally speaking, the results show low rates of social support for BD patients.Discussion Despite the growing interest in the overall functioning of patients with bipolar disorder, studies on social support are still rare. Besides, the existing studies on the subject use different methodologies, making it difficult to establish data comparisons.

  5. Electronic monitoring in bipolar disorder

    DEFF Research Database (Denmark)

    Faurholt-Jepsen, Maria

    2018-01-01

    generated data (e.g. the number of text messages sent/day; the number of incoming and outgoing calls/day; the number of changes in cell tower IDs/day; and voice features) seem to reflect clinically assessed depressive and manic symptoms in bipolar disorder; 3) smartphone-based electronic self-monitoring had...

  6. Integrated Neurobiology of Bipolar Disorder

    Science.gov (United States)

    Maletic, Vladimir; Raison, Charles

    2014-01-01

    From a neurobiological perspective there is no such thing as bipolar disorder. Rather, it is almost certainly the case that many somewhat similar, but subtly different, pathological conditions produce a disease state that we currently diagnose as bipolarity. This heterogeneity – reflected in the lack of synergy between our current diagnostic schema and our rapidly advancing scientific understanding of the condition – limits attempts to articulate an integrated perspective on bipolar disorder. However, despite these challenges, scientific findings in recent years are beginning to offer a provisional “unified field theory” of the disease. This theory sees bipolar disorder as a suite of related neurodevelopmental conditions with interconnected functional abnormalities that often appear early in life and worsen over time. In addition to accelerated loss of volume in brain areas known to be essential for mood regulation and cognitive function, consistent findings have emerged at a cellular level, providing evidence that bipolar disorder is reliably associated with dysregulation of glial–neuronal interactions. Among these glial elements are microglia – the brain’s primary immune elements, which appear to be overactive in the context of bipolarity. Multiple studies now indicate that inflammation is also increased in the periphery of the body in both the depressive and manic phases of the illness, with at least some return to normality in the euthymic state. These findings are consistent with changes in the hypothalamic–pituitary–adrenal axis, which are known to drive inflammatory activation. In summary, the very fact that no single gene, pathway, or brain abnormality is likely to ever account for the condition is itself an extremely important first step in better articulating an integrated perspective on both its ontological status and pathogenesis. Whether this perspective will translate into the discovery of innumerable more homogeneous forms of

  7. In Situ Identification and Stratification of Monochloramine Inhibition Effects on Nitrifying Biofilms as Determined by the Use of Microelectrodes

    Science.gov (United States)

    The nitrifying biofilm grown in an annular biofilm reactor and the microbial deactivation achieved after monochloramine treatment were investigated using microelectrodes. The nitrifying biofilm ammonium microprofile was measured and the effect of monochloramine on nitrifying bio...

  8. Vertically aligned carbon nanotube-sheathed carbon fibers as pristine microelectrodes for selective monitoring of ascorbate in vivo.

    Science.gov (United States)

    Xiang, Ling; Yu, Ping; Hao, Jie; Zhang, Meining; Zhu, Lin; Dai, Liming; Mao, Lanqun

    2014-04-15

    Using as-synthesized vertically aligned carbon nanotube-sheathed carbon fibers (VACNT-CFs) as microelectrodes without any postsynthesis functionalization, we have developed in this study a new method for in vivo monitoring of ascorbate with high selectivity and reproducibility. The VACNT-CFs are formed via pyrolysis of iron phthalocyanine (FePc) on the carbon fiber support. After electrochemical pretreatment in 1.0 M NaOH solution, the pristine VACNT-CF microelectrodes exhibit typical microelectrode behavior with fast electron transfer kinetics for electrochemical oxidation of ascorbate and are useful for selective ascorbate monitoring even with other electroactive species (e.g., dopamine, uric acid, and 5-hydroxytryptamine) coexisting in rat brain. Pristine VACNT-CFs are further demonstrated to be a reliable and stable microelectrode for in vivo recording of the dynamic increase of ascorbate evoked by intracerebral infusion of glutamate. Use of a pristine VACNT-CF microelectrode can effectively avoid any manual electrode modification and is free from person-to-person and/or electrode-to-electrode deviations intrinsically associated with conventional CF electrode fabrication, which often involves electrode surface modification with randomly distributed CNTs or other pretreatments, and hence allows easy fabrication of highly selective, reproducible, and stable microelectrodes even by nonelectrochemists. Thus, this study offers a new and reliable platform for in vivo monitoring of neurochemicals (e.g., ascorbate) to largely facilitate future studies on the neurochemical processes involved in various physiological events.

  9. Gold ultra-microelectrode arrays: application to the steady-state voltammetry of hydroxide ion in aqueous solution.

    Science.gov (United States)

    Ordeig, Olga; Banks, Craig E; Davies, Trevor J; del Campo, F Javier; Muñoz, Francesc Xavier; Compton, Richard G

    2006-05-01

    Gold ultra-microelectrode arrays are used to explore the electrochemical oxidation of hydroxide ions and are shown to be analytical useful. Two types of ultra-microelectrode arrays are used; the first consist of 256 individual electrodes of 5 microm in radius, 170 of which are electrochemically active in a cubic arrangement which are separated from their nearest neighbour by a distance of 100 microm. The second array compromises 2597 electrodes of 2.5 microm in radius and of which 1550 of which are electrochemically active in a hexagonal arrangement separated by the nearest neighbour by 55 microm. Well defined voltammetric waves are found with peak currents proportional to the concentration of hydroxide ions in the range 50 microM to 1 mM. Detection limits of 20 microM using the 170 ultra-microelectrode and 10 microM with the 1550 ultra-microelectrode array are shown to be possible but with a higher sensitivity of 4 mA M(-1) observed using the 1550 ultra-microelectrode array compared to 1.2 mA M(-1) with the 170 ultra-microelectrode array.

  10. Monitoring Ion Activities In and Around Cells Using Ion-Selective Liquid-Membrane Microelectrodes

    Directory of Open Access Journals (Sweden)

    Mark D. Parker

    2013-01-01

    Full Text Available Determining the effective concentration (i.e., activity of ions in and around living cells is important to our understanding of the contribution of those ions to cellular function. Moreover, monitoring changes in ion activities in and around cells is informative about the actions of the transporters and/or channels operating in the cell membrane. The activity of an ion can be measured using a glass microelectrode that includes in its tip a liquid-membrane doped with an ion-selective ionophore. Because these electrodes can be fabricated with tip diameters that are less than 1 μm, they can be used to impale single cells in order to monitor the activities of intracellular ions. This review summarizes the history, theory, and practice of ion-selective microelectrode use and brings together a number of classic and recent examples of their usefulness in the realm of physiological study.

  11. Theoretical and experimental comparison of microelectrode sensing configurations for impedimetric cell monitoring

    DEFF Research Database (Denmark)

    Carminati, M.; Caviglia, Claudia; Heiskanen, Arto

    2013-01-01

    microelectrodes using a versatile custom-made monitoring platform including a 24-channel miniaturized potentiostat. The characterization of bare microelectrodes in buffer and tracking experiments with HeLa cells over 16 hours demonstrate that the coplanar configuration provides a higher sensitivity to cell......A theoretical and experimental comparison between vertical and coplanar interdigitated sensing configurations for impedimetric cell growth tracking is presented. These widely-adopted approaches are quantitatively compared on the same cell populations and on the same 10 μm interdigitated...... adhesion and spreading (Cell Index = 1.6 vs. 0.4) albeit at a higher frequency of maximum sensitivity (100 kHz vs. 24 kHz) shifting over time. © 2014 Taylor & Francis Group....

  12. Nanowire-templated microelectrodes for high-sensitivity pH detection

    DEFF Research Database (Denmark)

    Antohe, V.A.; Radu, Adrian; Mátéfi-Tempfli, Mária

    2009-01-01

    A highly sensitive pH capacitive sensor has been designed by confined growth of vertically aligned nanowire arrays on interdigited microelectrodes. The active surface of the device has been functionalized with an electrochemical pH transducer (polyaniline). We easily tune the device features...... by combining lithographic techniques with electrochemical synthesis. The reported electrical LC resonance measurements show considerable sensitivity enhancement compared to conventional capacitive pH sensors realized with microfabricated interdigited electrodes. The sensitivity can be easily improved...

  13. Bipolar polygenic loading and bipolar spectrum features in major depressive disorder

    NARCIS (Netherlands)

    Wiste, Anna; Robinson, Elise B.; Milaneschi, Yuri; Meier, Sandra; Ripke, Stephan; Clements, Caitlin C.; Fitzmaurice, Garrett M.; Rietschel, Marcella; Penninx, Brenda W.; Smoller, Jordan W.; Perlis, Roy H.

    Objectives Family and genetic studies indicate overlapping liability for major depressive disorder and bipolar disorder. The purpose of the present study was to determine whether this shared genetic liability influences clinical presentation. Methods A polygenic risk score for bipolar disorder,

  14. Chronic, percutaneous connector for electrical recording and stimulation with microelectrode arrays.

    Science.gov (United States)

    Shah, Kedar G; Lee, Kye Young; Tolosa, Vanessa; Tooker, Angela; Felix, Sarah; Benett, William; Pannu, Satinderpall

    2014-01-01

    The translation of advances in neural stimulation and recording research into clinical practice hinges on the ability to perform chronic experiments in awake and behaving animal models. Advances in microelectrode array technology, most notably flexible polymer arrays, have significantly improved reliability of the neural interface. However, electrical connector technology has lagged and is prone to failure from non-biocompatibility, large size, contamination, corrosion, and difficulty of use. We present a novel chronic, percutaneous electrical connector system that is suitable for neural stimulation and recording. This system features biocompatible materials, low connect and disconnect forces, passive alignment, and a protective cap during non-use. We have successfully designed, assembled, and tested in vitro both a 16-channel system and a high density 64-channel system. Custom, polyimide, 16-channel, microelectrode arrays were electrically assembled with the connector system and tested using cyclic voltammetry and electrochemical impedance spectroscopy. This connector system is versatile and can be used with a variety of microelectrode array technologies for chronic studies.

  15. Microfabrication, characterization and in vivo MRI compatibility of diamond microelectrodes array for neural interfacing

    Energy Technology Data Exchange (ETDEWEB)

    Hébert, Clément, E-mail: clement.hebert@cea.fr [Institut Néel, CNRS et Université Joseph Fourier, BP 166, F-38042 Grenoble Cedex 9 (France); Warnking, Jan; Depaulis, Antoine [INSERM, U836, Grenoble Institut des Neurosciences, Grenoble (France); Garçon, Laurie Amandine [Institut Néel, CNRS et Université Joseph Fourier, BP 166, F-38042 Grenoble Cedex 9 (France); CEA/INAC/SPrAM/CREAB, 17 rue des Martyrs, 38054 Grenoble Cedex 9 (France); Mermoux, Michel [Université Grenoble Alpes, LEPMI, F-38000 Grenoble (France); CNRS, LEPMI, F-38000 Grenoble (France); Eon, David [Institut Néel, CNRS et Université Joseph Fourier, BP 166, F-38042 Grenoble Cedex 9 (France); Mailley, Pascal [CEA-LETI-DTBS Minatec, 17 rue des Martyres, 38054 Grenoble (France); Omnès, Franck [Institut Néel, CNRS et Université Joseph Fourier, BP 166, F-38042 Grenoble Cedex 9 (France)

    2015-01-01

    Neural interfacing still requires highly stable and biocompatible materials, in particular for in vivo applications. Indeed, most of the currently used materials are degraded and/or encapsulated by the proximal tissue leading to a loss of efficiency. Here, we considered boron doped diamond microelectrodes to address this issue and we evaluated the performances of a diamond microelectrode array. We described the microfabrication process of the device and discuss its functionalities. We characterized its electrochemical performances by cyclic voltammetry and impedance spectroscopy in saline buffer and observed the typical diamond electrode electrochemical properties, wide potential window and low background current, allowing efficient electrochemical detection. The charge storage capacitance and the modulus of the electrochemical impedance were found to remain in the same range as platinum electrodes used for standard commercial devices. Finally we observed a reduced Magnetic Resonance Imaging artifact when the device was implanted on a rat cortex, suggesting that boron doped-diamond is a very promising electrode material allowing functional imaging. - Highlights: • Microfabrication of all-diamond microelectrode array • Evaluation of as-grown nanocrystalline boron-doped diamond for electrical neural interfacing • MRI compatibility of nanocrystalline boron-doped diamond.

  16. Static and Dynamic Measurement of Dopamine Adsorption in Carbon Fiber Microelectrodes Using Electrochemical Impedance Spectroscopy.

    Science.gov (United States)

    Rivera-Serrano, Nilka; Pagan, Miraida; Colón-Rodríguez, Joanisse; Fuster, Christian; Vélez, Román; Almodovar-Faria, Jose; Jiménez-Rivera, Carlos; Cunci, Lisandro

    2018-02-06

    In this study, electrochemical impedance spectroscopy was used for the first time to study the adsorption of dopamine in carbon fiber microelectrodes. In order to show a proof-of-concept, static and dynamic measurements were taken at potentials ranging from -0.4 to 0.8 V versus Ag|AgCl to demonstrate the versatility of this technique to study dopamine without the need of its oxidation. We used electrochemical impedance spectroscopy and single frequency electrochemical impedance to measure different concentrations of dopamine as low as 1 nM. Moreover, the capacitance of the microelectrodes surface was found to decrease due to dopamine adsorption, which is dependent on its concentration. The effect of dissolved oxygen and electrochemical oxidation of the surface in the detection of dopamine was also studied. Nonoxidized and oxidized carbon fiber microelectrodes were prepared and characterized by optical microscopy, scanning electron microscopy, cyclic voltammetry, and electrochemical impedance spectroscopy. Optimum working parameters of the electrodes, such as frequency and voltage, were obtained for better measurement. Electrochemical impedance of dopamine was determined at different concentration, voltages, and frequencies. Finally, dynamic experiments were conducted using a flow cell and single frequency impedance in order to study continuous and real-time measurements of dopamine.

  17. Field-programmable lab-on-a-chip based on microelectrode dot array architecture.

    Science.gov (United States)

    Wang, Gary; Teng, Daniel; Lai, Yi-Tse; Lu, Yi-Wen; Ho, Yingchieh; Lee, Chen-Yi

    2014-09-01

    The fundamentals of electrowetting-on-dielectric (EWOD) digital microfluidics are very strong: advantageous capability in the manipulation of fluids, small test volumes, precise dynamic control and detection, and microscale systems. These advantages are very important for future biochip developments, but the development of EWOD microfluidics has been hindered by the absence of: integrated detector technology, standard commercial components, on-chip sample preparation, standard manufacturing technology and end-to-end system integration. A field-programmable lab-on-a-chip (FPLOC) system based on microelectrode dot array (MEDA) architecture is presented in this research. The MEDA architecture proposes a standard EWOD microfluidic component called 'microelectrode cell', which can be dynamically configured into microfluidic components to perform microfluidic operations of the biochip. A proof-of-concept prototype FPLOC, containing a 30 × 30 MEDA, was developed by using generic integrated circuits computer aided design tools, and it was manufactured with standard low-voltage complementary metal-oxide-semiconductor technology, which allows smooth on-chip integration of microfluidics and microelectronics. By integrating 900 droplet detection circuits into microelectrode cells, the FPLOC has achieved large-scale integration of microfluidics and microelectronics. Compared to the full-custom and bottom-up design methods, the FPLOC provides hierarchical top-down design approach, field-programmability and dynamic manipulations of droplets for advanced microfluidic operations.

  18. Novel microelectrode-based online system for monitoring N2O gas emissions during wastewater treatment.

    Science.gov (United States)

    Marques, Ricardo; Oehmen, Adrian; Pijuan, Maite

    2014-11-04

    Clark-type nitrous oxide (N2O) microelectrodes are commonly used for measuring dissolved N2O levels, but have not previously been tested for gas-phase applications, where the N2O emitted from wastewater systems can be directly quantified. In this study, N2O microelectrodes were tested and validated for online gas measurements, and assessed with respect to their temperature, gas flow, composition dependence, gas pressure, and humidity. An exponential correlation between temperature and sensor signal was found, whereas gas flow, composition, pressure, and humidity did not have any influence on the signal. Two of the sensors were tested at different N2O concentration ranges (0-422.3, 0-50, 0-10, and 0-2 ppmv N2O) and exhibited a linear response over each range. The N2O emission dynamics from two laboratory scale sequencing batch reactors performing ammonia or nitrite oxidation were also monitored using one of the microsensors and results were compared with two other analytical methods. Results show that N2O emissions were accurately described with these microelectrodes and support their application for assessing gaseous N2O emissions from wastewater treatment systems. Advantages of the sensors as compared to conventional measurement techniques include a wider quantification range of N2O fluxes, and a single measurement system that can assess both liquid and gas-phase N2O dynamics.

  19. Unsplit bipolar pulse forming line

    Science.gov (United States)

    Rhodes, Mark A [Pleasanton, CA

    2011-05-24

    A bipolar pulse forming transmission line module and system for linear induction accelerators having first, second, third, and fourth planar conductors which form a sequentially arranged interleaved stack having opposing first and second ends, with dielectric layers between the conductors. The first and second planar conductors are connected to each other at the first end, and the first and fourth planar conductors are connected to each other at the second end via a shorting plate. The third planar conductor is electrically connectable to a high voltage source, and an internal switch functions to short at the first end a high voltage from the third planar conductor to the fourth planar conductor to produce a bipolar pulse at the acceleration axis with a zero net time integral. Improved access to the switch is enabled by an aperture through the shorting plate and the proximity of the aperture to the switch.

  20. Course of Subthreshold Bipolar Disorder in Youth: Diagnostic Progression from Bipolar Disorder Not Otherwise Specified

    Science.gov (United States)

    Axelson, David A.; Birmaher, Boris; Strober, Michael A.; Goldstein, Benjamin I.; Ha, Wonho; Gill, Mary Kay; Goldstein, Tina R.; Yen, Shirley; Hower, Heather; Hunt, Jeffrey I.; Liao, Fangzi; Iyengar, Satish; Dickstein, Daniel; Kim, Eunice; Ryan, Neal D.; Frankel, Erica; Keller, Martin B.

    2011-01-01

    Objective: To determine the rate of diagnostic conversion from an operationalized diagnosis of bipolar disorder not otherwise specified (BP-NOS) to bipolar I disorder (BP-I) or bipolar II disorder (BP-II) in youth over prospective follow-up and to identify factors associated with conversion. Method: Subjects were 140 children and adolescents…

  1. Bipolar (spectrum) disorder and mood stabilization: standing at the crossroads?

    OpenAIRE

    De Fruyt, Jurgen; Demyttenaere, Koen

    2007-01-01

    Diagnosis and treatment of bipolar disorder has long been a neglected discipline. Recent years have shown an upsurge in bipolar research. When compared to major depressive disorder, bipolar research still remains limited and more expert based than evidence based. In bipolar diagnosis the focus is shifting from classic mania to bipolar depression and hypomania. There is a search for bipolar signatures in symptoms and course of major depressive episodes. The criteria for hypomania are softened,...

  2. [Bipolar disorders in DSM-5].

    Science.gov (United States)

    Severus, E; Bauer, M

    2014-05-01

    In spring 2013 the fifth edition of the Diagnostic and Statistical Manual of Mental Disorders (DSM-5) edited by the American Psychiatric Association was published. The DSM-5 has also brought some important changes regarding bipolar disorders. The goal of this manuscript is to review the novelties in DSM-5 and to evaluate the implications of these changes. The diagnostic criteria as well as the additional remarks provided in the running text of DSM-5 were carefully appraised. For the first time diagnostic criteria are provided for disorders which up to now have been considered as subthreshold bipolar disorders. Furthermore, mixed episodes were eliminated and instead a mixed specifier was introduced. An increase in goal-directed activity/energy is now one of the obligatory symptoms for a (hypo)manic episode. Diagnostic guidance is provided as to when a (hypo)manic episode that has developed during treatment with an antidepressant has to be judged to be causally related to antidepressants and when this episode has only occurred coincidentally with antidepressant use. While some of the novelties are clearly useful, e.g. addition of increased goal-directed activity/energy as obligatory symptom for (hypo)manic episodes, this remains to be demonstrated for others, such as the definition of various subthreshold bipolar disorders.

  3. Virginia Woolf, neuroprogression, and bipolar disorder

    Directory of Open Access Journals (Sweden)

    Manuela V. Boeira

    2016-01-01

    Full Text Available Family history and traumatic experiences are factors linked to bipolar disorder. It is known that the lifetime risk of bipolar disorder in relatives of a bipolar proband are 5-10% for first degree relatives and 40-70% for monozygotic co-twins. It is also known that patients with early childhood trauma present earlier onset of bipolar disorder, increased number of manic episodes, and more suicide attempts. We have recently reported that childhood trauma partly mediates the effect of family history on bipolar disorder diagnosis. In light of these findings from the scientific literature, we reviewed the work of British writer Virginia Woolf, who allegedly suffered from bipolar disorder. Her disorder was strongly related to her family background. Moreover, Virginia Woolf was sexually molested by her half siblings for nine years. Her bipolar disorder symptoms presented a pernicious course, associated with hospitalizations, suicidal behavioral, and functional impairment. The concept of neuroprogression has been used to explain the clinical deterioration that takes places in a subgroup of bipolar disorder patients. The examination of Virgina Woolf’s biography and art can provide clinicians with important insights about the course of bipolar disorder.

  4. Bipolar Disorder and Obsessive Compulsive Disorder Comorbidity

    Directory of Open Access Journals (Sweden)

    Necla Keskin

    2014-08-01

    Full Text Available The comorbidity of bipolar disorder and anxiety disorders is a well known concept. Obsessive-compulsive disorder is the most commonly seen comorbid anxiety disorder in bipolar patients. Some genetic variants, neurotransmitters especially serotonergic systems and second-messenger systems are thought to be responsible for its etiology. Bipolar disorder alters the clinical aspects of obsessive compulsive disorder and is associated with poorer outcome. The determination of comorbidity between bipolar disorder and obsessive compulsive disorder is quite important for appropriate clinical management and treatment. [Psikiyatride Guncel Yaklasimlar - Current Approaches in Psychiatry 2014; 6(4.000: 429-437

  5. [Lithium and anticonvulsants in bipolar depression].

    Science.gov (United States)

    Samalin, L; Nourry, A; Llorca, P-M

    2011-12-01

    For decades, lithium and anticonvulsants have been widely used in the treatment of bipolar disorder. Their efficacy in the treatment of mania is recognized. These drugs have been initially evaluated in old and methodologically heterogeneous studies. Their efficacy in bipolar depression has not always been confirmed in more recent and methodologically more reliable studies. Thus, lithium's efficacy as monotherapy was challenged by the study of Young (2008) that showed a lack of efficacy compared with placebo in the treatment of bipolar depression. In two recent meta-analyses, valproate has shown a modest efficacy in the treatment of bipolar depression. As for lithium, valproate appeared to have a larger antimanic effect for acute phase and prophylaxis of bipolar disorder. In contrast, lamotrigine is more effective on the depressive pole of bipolar disorder with better evidence for the prevention of depressive recurrences. The guidelines include these recent studies and recommend lamotrigine as a first-line treatment of bipolar depression and for maintenance treatment. Because of more discordant data concerning lithium and valproate, these two drugs are placed either as first or as second line treatment of bipolar depression. The different safety/efficacy ratios of mood stabilizers underlie the complementarity and the importance of combination between them, or with some second-generation antipsychotics, in the treatment of patients with bipolar disorder. Copyright © 2011 L’Encéphale. Published by Elsevier Masson SAS.. All rights reserved.

  6. Late Onset Bipolar Disorder: Case Report

    Directory of Open Access Journals (Sweden)

    Filipa Araújo

    2016-07-01

    Full Text Available Background: Bipolar disorder affects approximately 1% of the population, with diagnosis often being made during late adolescence and early adulthood, and only rarely (0.1% in the elderly. Late onset bipolar disorder in the elderly has a impact on the nature and course of bipolar disorder. Aims: The authors report a case of bipolar disorder emerging in late life  (76years old with no cleary identified organic cause. Conclusion: This case highlights the importance of a broad differential diagnosis and pharmacologic management when approaching new-onset manic/depressive symptoms among geriatric patients.

  7. Dysfunctional gaze processing in bipolar disorder

    Directory of Open Access Journals (Sweden)

    Cristina Berchio

    2017-01-01

    The present study provides neurophysiological evidence for abnormal gaze processing in BP and suggests dysfunctional processing of direct eye contact as a prominent characteristic of bipolar disorder.

  8. Localized electron transfer rates and microelectrode-based enrichment of microbial communities within a phototrophic microbial mat

    Directory of Open Access Journals (Sweden)

    Jerome eBabauta

    2014-01-01

    Full Text Available Phototrophic microbial mats frequently exhibit sharp, light-dependent redox gradients that regulate microbial respiration on specific electron acceptors as a function of depth. In this work, a benthic phototrophic microbial mat from Hot Lake, a hypersaline, epsomitic lake located near Oroville in north-central Washington, was used to develop a microscale electrochemical method to study local electron transfer processes within the mat. To characterize the physicochemical variables influencing electron transfer, we initially quantified redox potential, pH and dissolved oxygen gradients by depth in the mat under photic and aphotic conditions. We further demonstrated that power output of a mat fuel cell was light-dependent. To study local electron transfer processes, we deployed a microscale electrode (microelectrode with tip size ~20 µm. To enrich a subset of microorganisms capable of interacting with the microelectrode, we anodically polarized the microelectrode in the mat. Subsequently, to characterize the microelectrode-associated community and compare it to the neighboring mat community, we performed amplicon sequencing of the V1-V3 region of the 16S gene. Differences in Bray-Curtis beta diversity, illustrated by large changes in relative abundance at the phylum level, suggested successful enrichment of specific mat community members on the microelectrode surface. The microelectrode-associated community exhibited substantially reduced alpha diversity and elevated relative abundances of Prosthecochloris, Loktanella, Catellibacterium, other unclassified members of Rhodobacteraceae, Thiomicrospira, and Limnobacter, compared with the community at an equivalent depth in the mat. Our results suggest that local electron transfer to an anodically polarized microelectrode selected for a specific microbial population, with substantially more abundance and diversity of sulfur-oxidizing phylotypes compared with the neighboring mat community.

  9. Localized electron transfer rates and microelectrode-based enrichment of microbial communities within a phototrophic microbial mat.

    Science.gov (United States)

    Babauta, Jerome T; Atci, Erhan; Ha, Phuc T; Lindemann, Stephen R; Ewing, Timothy; Call, Douglas R; Fredrickson, James K; Beyenal, Haluk

    2014-01-01

    Phototrophic microbial mats frequently exhibit sharp, light-dependent redox gradients that regulate microbial respiration on specific electron acceptors as a function of depth. In this work, a benthic phototrophic microbial mat from Hot Lake, a hypersaline, epsomitic lake located near Oroville in north-central Washington, was used to develop a microscale electrochemical method to study local electron transfer processes within the mat. To characterize the physicochemical variables influencing electron transfer, we initially quantified redox potential, pH, and dissolved oxygen gradients by depth in the mat under photic and aphotic conditions. We further demonstrated that power output of a mat fuel cell was light-dependent. To study local electron transfer processes, we deployed a microscale electrode (microelectrode) with tip size ~20 μm. To enrich a subset of microorganisms capable of interacting with the microelectrode, we anodically polarized the microelectrode at depth in the mat. Subsequently, to characterize the microelectrode-associated community and compare it to the neighboring mat community, we performed amplicon sequencing of the V1-V3 region of the 16S gene. Differences in Bray-Curtis beta diversity, illustrated by large changes in relative abundance at the phylum level, suggested successful enrichment of specific mat community members on the microelectrode surface. The microelectrode-associated community exhibited substantially reduced alpha diversity and elevated relative abundances of Prosthecochloris, Loktanella, Catellibacterium, other unclassified members of Rhodobacteraceae, Thiomicrospira, and Limnobacter, compared with the community at an equivalent depth in the mat. Our results suggest that local electron transfer to an anodically polarized microelectrode selected for a specific microbial population, with substantially more abundance and diversity of sulfur-oxidizing phylotypes compared with the neighboring mat community.

  10. Bipolar mixed features - Results from the comparative effectiveness for bipolar disorder (Bipolar CHOICE) study.

    Science.gov (United States)

    Tohen, Mauricio; Gold, Alexandra K; Sylvia, Louisa G; Montana, Rebecca E; McElroy, Susan L; Thase, Michael E; Rabideau, Dustin J; Nierenberg, Andrew A; Reilly-Harrington, Noreen A; Friedman, Edward S; Shelton, Richard C; Bowden, Charles L; Singh, Vivek; Deckersbach, Thilo; Ketter, Terence A; Calabrese, Joseph R; Bobo, William V; McInnis, Melvin G

    2017-08-01

    DSM-5 changed the criteria from DSM-IV for mixed features in mood disorder episodes to include non-overlapping symptoms of depression and hypomania/mania. It is unknown if, by changing these criteria, the same group would qualify for mixed features. We assessed how those meeting DSM-5 criteria for mixed features compare to those meeting DSM-IV criteria. We analyzed data from 482 adult bipolar patients in Bipolar CHOICE, a randomized comparative effectiveness trial. Bipolar diagnoses were confirmed through the MINI International Neuropsychiatric Interview (MINI). Presence and severity of mood symptoms were collected with the Bipolar Inventory of Symptoms Scale (BISS) and linked to DSM-5 and DSM-IV mixed features criteria. Baseline demographics and clinical variables were compared between mood episode groups using ANOVA for continuous variables and chi-square tests for categorical variables. At baseline, the frequency of DSM-IV mixed episodes diagnoses obtained with the MINI was 17% and with the BISS was 20%. Using DSM-5 criteria, 9% of participants met criteria for hypomania/mania with mixed features and 12% met criteria for a depressive episode with mixed features. Symptom severity was also associated with increased mixed features with a high rate of mixed features in patients with mania/hypomania (63.8%) relative to those with depression (8.0%). Data on mixed features were collected at baseline only and thus do not reflect potential patterns in mixed features within this sample across the study duration. The DSM-5 narrower, non-overlapping definition of mixed episodes resulted in fewer patients who met mixed criteria compared to DSM-IV. Copyright © 2017. Published by Elsevier B.V.

  11. Inhibition of the cluster of differentiation 14 innate immunity pathway with IAXO-101 improves chronic microelectrode performance

    Science.gov (United States)

    Hermann, John K.; Ravikumar, Madhumitha; Shoffstall, Andrew J.; Ereifej, Evon S.; Kovach, Kyle M.; Chang, Jeremy; Soffer, Arielle; Wong, Chun; Srivastava, Vishnupriya; Smith, Patrick; Protasiewicz, Grace; Jiang, Jingle; Selkirk, Stephen M.; Miller, Robert H.; Sidik, Steven; Ziats, Nicholas P.; Taylor, Dawn M.; Capadona, Jeffrey R.

    2018-04-01

    Objective. Neuroinflammatory mechanisms are hypothesized to contribute to intracortical microelectrode failures. The cluster of differentiation 14 (CD14) molecule is an innate immunity receptor involved in the recognition of pathogens and tissue damage to promote inflammation. The goal of the study was to investigate the effect of CD14 inhibition on intracortical microelectrode recording performance and tissue integration. Approach. Mice implanted with intracortical microelectrodes in the motor cortex underwent electrophysiological characterization for 16 weeks, followed by endpoint histology. Three conditions were examined: (1) wildtype control mice, (2) knockout mice lacking CD14, and (3) wildtype control mice administered a small molecule inhibitor to CD14 called IAXO-101. Main results. The CD14 knockout mice exhibited acute but not chronic improvements in intracortical microelectrode performance without significant differences in endpoint histology. Mice receiving IAXO-101 exhibited significant improvements in recording performance over the entire 16 week duration without significant differences in endpoint histology. Significance. Full removal of CD14 is beneficial at acute time ranges, but limited CD14 signaling is beneficial at chronic time ranges. Innate immunity receptor inhibition strategies have the potential to improve long-term intracortical microelectrode performance.

  12. Transient Stuttering in Catatonic Bipolar Patients

    Directory of Open Access Journals (Sweden)

    Anthony B. Joseph

    1991-01-01

    Full Text Available Two cases of transient stuttering occurring in association with catatonia and bipolar disorder are described. Affective decompensation has been associated with lateralized cerebral dysfunction, and it is hypothesized that in some bipolar catatonic patients a concomitant disorder of the lateralization of language function may lead to a variety of clinical presentations including aphasia, mutism, and stuttering.

  13. Swimming in Deep Water: Childhood Bipolar Disorder

    Science.gov (United States)

    Senokossoff, Gwyn W.; Stoddard, Kim

    2009-01-01

    The authors focused on one parent's struggles in finding a diagnosis and intervention for a child who had bipolar disorder. The authors explain the process of identification, diagnosis, and intervention of a child who had bipolar disorder. In addition to the personal story, the authors provide information on the disorder and outline strategies…

  14. Bipolar disorder diagnosis: challenges and future directions

    Science.gov (United States)

    Phillips, Mary L; Kupfer, David J

    2018-01-01

    Bipolar disorder refers to a group of affective disorders, which together are characterised by depressive and manic or hypomanic episodes. These disorders include: bipolar disorder type I (depressive and manic episodes: this disorder can be diagnosed on the basis of one manic episode); bipolar disorder type II (depressive and hypomanic episodes); cyclothymic disorder (hypomanic and depressive symptoms that do not meet criteria for depressive episodes); and bipolar disorder not otherwise specified (depressive and hypomanic-like symptoms that do not meet the diagnostic criteria for any of the aforementioned disorders). Bipolar disorder type II is especially difficult to diagnose accurately because of the difficulty in differentiation of this disorder from recurrent unipolar depression (recurrent depressive episodes) in depressed patients. The identification of objective biomarkers that represent pathophysiologic processes that differ between bipolar disorder and unipolar depression can both inform bipolar disorder diagnosis and provide biological targets for the development of new and personalised treatments. Neuroimaging studies could help the identification of biomarkers that differentiate bipolar disorder from unipolar depression, but the problem in detection of a clear boundary between these disorders suggests that they might be better represented as a continuum of affective disorders. Innovative combinations of neuroimaging and pattern recognition approaches can identify individual patterns of neural structure and function that accurately ascertain where a patient might lie on a behavioural scale. Ultimately, an integrative approach, with several biological measurements using different scales, could yield patterns of biomarkers (biosignatures) to help identify biological targets for personalised and new treatments for all affective disorders. PMID:23663952

  15. Bipolar Disorder and Cognitive Therapy: A Commentary

    Science.gov (United States)

    Riskind, John H.

    2005-01-01

    This article comments on the three articles (Leahy, 2005; Newman, 2005; and Reilly-Harrington & Knauz, 2005) that deal with the applications of cognitive therapy to treatment of bipolar disorder. They focus on the uses of cognitive therapy in treating three important facets of the special problems of bipolar patients: rapid cycling, severe…

  16. Perceived parental rearing of bipolar offspring

    NARCIS (Netherlands)

    Reichart, C. G.; van der Ende, J.; Hillegers, M. H. J.; Wals, M.; Bongers, I. L.; Nolen, W. A.; Ormel, J.; Verhulst, F. C.

    Objective: To explore the impact of growing up with a parent with a bipolar disorder. First, we compared parental rearing behavior perceived by young adult offspring of bipolar parents with parental rearing behavior perceived by same aged young adults from the general population. Secondly, we

  17. Cognitive behavioral therapy for bipolar disorders

    OpenAIRE

    Lotufo Neto, Francisco

    2004-01-01

    Descrição dos objetivos e principais técnicas da terapia comportamental cognitiva usadas para a psicoterapia das pessoas com transtorno bipolar.Objectives and main techniques of cognitive behavior therapy for the treatment of bipolar disorder patients are described.

  18. 2017 Bipolar Plate Workshop Summary Report

    Energy Technology Data Exchange (ETDEWEB)

    Kopasz, John P. [Argonne National Lab. (ANL), Argonne, IL (United States); Benjamin, Thomas G. [Argonne National Lab. (ANL), Argonne, IL (United States); Schenck, Deanna [Argonne National Lab. (ANL), Argonne, IL (United States)

    2017-08-17

    The Bipolar Plate (BP) Workshop was held at USCAR1 in Southfield, Michigan on February 14, 2017 and included 63 participants from industry, government agencies, universities, and national laboratories with expertise in the relevant fields. The objective of the workshop was to identify research and development (R&D) needs, in particular early-stage R&D, for bipolar plates for polymer electrolyte membrane (PEM) fuel cells for transportation applications. The focus of the workshop was on materials, manufacturing, and design aspects of bipolar plates with the goal of meeting DOE’s 2020 bipolar plate targets. Of special interest was the cost target of ≤$3/kW for the bipolar plate.

  19. Low-loss microelectrodes fabricated using reverse-side exposure for a tunable ferroelectric capacitor application

    Science.gov (United States)

    Yoon, Yong-Kyu; Stevenson Kenney, J.; Hunt, Andrew T.; Allen, Mark G.

    2006-02-01

    Narrowly spaced thick microelectrodes are fabricated using a self-aligned multiple reverse-side exposure scheme for an improved quality-factor tunable ferroelectric capacitor. The microelectrodes are fabricated on a functional substrate—a thin film ferroelectric (barium strontium titanate, BST; BaxSr1-xTiO3) coated sapphire substrate, which has an electric-field-dependent dielectric property providing tuning functionality, as well as UV transparency permitting an additional degree of freedom in photolithography steps. The microelectrode process has been applied to interdigitated capacitor fabrication, where a critical challenge is maintaining narrow gaps between electrodes for high tunability, while simultaneously forming thick electrodes to minimize conductor loss. A single mask, self-aligned reverse-side exposure through the transparent substrate achieves both these goals. A single-finger test capacitor with an electrode gap of 1.2 µm and an electrode thickness of 2.2 µm is fabricated and characterized. Tunability (T = 100 × (C0 - Cbias)/C0) of 33% at 10 V has been achieved at 100 kHz. The 2.2 µm thick structure shows improvement of Q-factor compared to that of a 0.1 µm thick structure. To demonstrate the scalability of this process, a 102-finger interdigitated capacitor is fabricated and characterized at 100 kHz and 1 GHz. The structure is embedded in a 25 µm thick epoxy resin SU-8 for passivation. A quality factor decrease of 15-25%, tunability decrease of 2-3% and capacitance increase of 6% are observed due to the expoxy resin after passivation. High frequency performance of the capacitor has been measured to be 15.9 pF of capacitance, 28.1% tunability at 10 V and a quality factor of 16 (at a 10 V dc bias) at 1 GHz.

  20. Modeling microelectrode biosensors: free-flow calibration can substantially underestimate tissue concentrations.

    Science.gov (United States)

    Newton, Adam J H; Wall, Mark J; Richardson, Magnus J E

    2017-03-01

    Microelectrode amperometric biosensors are widely used to measure concentrations of analytes in solution and tissue including acetylcholine, adenosine, glucose, and glutamate. A great deal of experimental and modeling effort has been directed at quantifying the response of the biosensors themselves; however, the influence that the macroscopic tissue environment has on biosensor response has not been subjected to the same level of scrutiny. Here we identify an important issue in the way microelectrode biosensors are calibrated that is likely to have led to underestimations of analyte tissue concentrations. Concentration in tissue is typically determined by comparing the biosensor signal to that measured in free-flow calibration conditions. In a free-flow environment the concentration of the analyte at the outer surface of the biosensor can be considered constant. However, in tissue the analyte reaches the biosensor surface by diffusion through the extracellular space. Because the enzymes in the biosensor break down the analyte, a density gradient is set up resulting in a significantly lower concentration of analyte near the biosensor surface. This effect is compounded by the diminished volume fraction (porosity) and reduction in the diffusion coefficient due to obstructions (tortuosity) in tissue. We demonstrate this effect through modeling and experimentally verify our predictions in diffusive environments. NEW & NOTEWORTHY Microelectrode biosensors are typically calibrated in a free-flow environment where the concentrations at the biosensor surface are constant. However, when in tissue, the analyte reaches the biosensor via diffusion and so analyte breakdown by the biosensor results in a concentration gradient and consequently a lower concentration around the biosensor. This effect means that naive free-flow calibration will underestimate tissue concentration. We develop mathematical models to better quantify the discrepancy between the calibration and tissue

  1. DeepBipolar: Identifying genomic mutations for bipolar disorder via deep learning.

    Science.gov (United States)

    Laksshman, Sundaram; Bhat, Rajendra Rana; Viswanath, Vivek; Li, Xiaolin

    2017-09-01

    Bipolar disorder, also known as manic depression, is a brain disorder that affects the brain structure of a patient. It results in extreme mood swings, severe states of depression, and overexcitement simultaneously. It is estimated that roughly 3% of the population of the United States (about 5.3 million adults) suffers from bipolar disorder. Recent research efforts like the Twin studies have demonstrated a high heritability factor for the disorder, making genomics a viable alternative for detecting and treating bipolar disorder, in addition to the conventional lengthy and costly postsymptom clinical diagnosis. Motivated by this study, leveraging several emerging deep learning algorithms, we design an end-to-end deep learning architecture (called DeepBipolar) to predict bipolar disorder based on limited genomic data. DeepBipolar adopts the Deep Convolutional Neural Network (DCNN) architecture that automatically extracts features from genotype information to predict the bipolar phenotype. We participated in the Critical Assessment of Genome Interpretation (CAGI) bipolar disorder challenge and DeepBipolar was considered the most successful by the independent assessor. In this work, we thoroughly evaluate the performance of DeepBipolar and analyze the type of signals we believe could have affected the classifier in distinguishing the case samples from the control set. © 2017 Wiley Periodicals, Inc.

  2. DNA-barcode directed capture and electrochemical metabolic analysis of single mammalian cells on a microelectrode array.

    Science.gov (United States)

    Douglas, Erik S; Hsiao, Sonny C; Onoe, Hiroaki; Bertozzi, Carolyn R; Francis, Matthew B; Mathies, Richard A

    2009-07-21

    A microdevice is developed for DNA-barcode directed capture of single cells on an array of pH-sensitive microelectrodes for metabolic analysis. Cells are modified with membrane-bound single-stranded DNA, and specific single-cell capture is directed by the complementary strand bound in the sensor area of the iridium oxide pH microelectrodes within a microfluidic channel. This bifunctional microelectrode array is demonstrated for the pH monitoring and differentiation of primary T cells and Jurkat T lymphoma cells. Single Jurkat cells exhibited an extracellular acidification rate of 11 milli-pH min(-1), while primary T cells exhibited only 2 milli-pH min(-1). This system can be used to capture non-adherent cells specifically and to discriminate between visually similar healthy and cancerous cells in a heterogeneous ensemble based on their altered metabolic properties.

  3. Electrohydrodynamic actuation of co-flowing liquids by means of microelectrode arrays

    International Nuclear Information System (INIS)

    Garcia-Sanchez, Pablo; Ferney, Mathieu; Ramos, Antonio

    2011-01-01

    Electric fields induce forces at the interface between liquids with different electrical properties (conductivity and/or permittivity). We explore how to use these forces for manipulating two coflowing streams of liquids in a microchannel. A microelectrode array is fabricated at the bottom of the channel and one of the two liquids is labelled with a fluorescent dye for observing the phenomenon. The diffuse interface between the two liquids is deflected depending on the ac signal and conductivity (or permittivity) ratio between the liquids. Only a few volts are needed for observing the interface destabilization, in contrast with other electrode configurations where hundreds of volts are applied.

  4. Electrohydrodynamic actuation of co-flowing liquids by means of microelectrode arrays

    Energy Technology Data Exchange (ETDEWEB)

    Garcia-Sanchez, Pablo; Ferney, Mathieu; Ramos, Antonio, E-mail: pablogarcia@us.es [Depto. de Electronica y Electromagnetismo, University of Sevilla (Spain)

    2011-06-23

    Electric fields induce forces at the interface between liquids with different electrical properties (conductivity and/or permittivity). We explore how to use these forces for manipulating two coflowing streams of liquids in a microchannel. A microelectrode array is fabricated at the bottom of the channel and one of the two liquids is labelled with a fluorescent dye for observing the phenomenon. The diffuse interface between the two liquids is deflected depending on the ac signal and conductivity (or permittivity) ratio between the liquids. Only a few volts are needed for observing the interface destabilization, in contrast with other electrode configurations where hundreds of volts are applied.

  5. A YinYang bipolar fuzzy cognitive TOPSIS method to bipolar disorder diagnosis.

    Science.gov (United States)

    Han, Ying; Lu, Zhenyu; Du, Zhenguang; Luo, Qi; Chen, Sheng

    2018-05-01

    Bipolar disorder is often mis-diagnosed as unipolar depression in the clinical diagnosis. The main reason is that, different from other diseases, bipolarity is the norm rather than exception in bipolar disorder diagnosis. YinYang bipolar fuzzy set captures bipolarity and has been successfully used to construct a unified inference mathematical modeling method to bipolar disorder clinical diagnosis. Nevertheless, symptoms and their interrelationships are not considered in the existing method, circumventing its ability to describe complexity of bipolar disorder. Thus, in this paper, a YinYang bipolar fuzzy multi-criteria group decision making method to bipolar disorder clinical diagnosis is developed. Comparing with the existing method, the new one is more comprehensive. The merits of the new method are listed as follows: First of all, multi-criteria group decision making method is introduced into bipolar disorder diagnosis for considering different symptoms and multiple doctors' opinions. Secondly, the discreet diagnosis principle is adopted by the revised TOPSIS method. Last but not the least, YinYang bipolar fuzzy cognitive map is provided for the understanding of interrelations among symptoms. The illustrated case demonstrates the feasibility, validity, and necessity of the theoretical results obtained. Moreover, the comparison analysis demonstrates that the diagnosis result is more accurate, when interrelations about symptoms are considered in the proposed method. In a conclusion, the main contribution of this paper is to provide a comprehensive mathematical approach to improve the accuracy of bipolar disorder clinical diagnosis, in which both bipolarity and complexity are considered. Copyright © 2018 Elsevier B.V. All rights reserved.

  6. Lower switch rate in depressed patients with bipolar II than bipolar I disorder treated adjunctively with second-generation antidepressants

    NARCIS (Netherlands)

    Altshuler, LL; Suppes, T; Nolen, WA; Leverich, G; Keck, PE; Frye, MA; Kupka, R; McElroy, SL; Grunze, H; Kitchen, CMR; Post, R; Black, D.O.

    Objectives: The authors compared the switch rate into hypomania/mania in depressed patients treated with second-generation antidepressants who had either bipolar I or bipolar II disorder. Method: In a 10-week trial, 184 outpatients with bipolar depression (134 with bipolar I disorder, 48 with

  7. Brief Report: A Family Risk Study Exploring Bipolar Spectrum Problems and Cognitive Biases in Adolescent Children of Bipolar Parents

    Science.gov (United States)

    Espie, Jonathan; Jones, Steven H.; Vance, Yvonne H.; Tai, Sara J.

    2012-01-01

    Children of parents with bipolar disorder are at increased risk of bipolar spectrum diagnoses. This cross-sectional study explores cognitive factors in the prediction of vulnerability to bipolar disorder. Adolescents at high-risk (with a parent with bipolar disorder; n = 23) and age and gender matched adolescents (n = 24) were recruited. Parent…

  8. VALPROATE, BIPOLAR DISORDER AND POLYCYSTIC OVARIAN SYNDROME.

    Science.gov (United States)

    Okanović, Milana; Zivanović, Olga

    2016-01-01

    Polycystic ovarian syndrome is a syndrome of ovarian dysfunction with the principal features of hyperandrogenism and polycystic ovary morphology. A large number of studies conducted on this topic have suggested a possible role of anticonvulsants, particularly valproate, in the pathogenesis or risk factors associated with polycystic ovarian syndrome. Bipolar treatment guidelines from Canada and the United States of America recommend valproate as the first line strategy in the acute treatment of bipolar disorder. Most persons with bipolar disorder require maintenance treatment. Long-term administration of valproate in women with bipolar disorder or epilepsy is believed to result in the increased risk of hyperandrogenism, menstrual abnormalities and polycystic ovaries. Valproate may also increase the risk of infertility and other associated symptoms of polycystic ovarian syndrome. Therefore, particular caution is indicated in the use of valproate in women of reproductive age. The treatment of the female patients with bipolar disorder presents various challenges for the clinician. Every woman of reproductive age needs to know the risk and benefits of her pharmacologic treatment options. Bipolar disorder should be considered chronic disorder, whose development is largely affected by hormonal changes and reproductive cycle in women. These issues should be researched more thoroughly in order to opt for the most appropriate treatment in women with bipolar disorder.

  9. Bipolar plates for PEM fuel cells

    Science.gov (United States)

    Middelman, E.; Kout, W.; Vogelaar, B.; Lenssen, J.; de Waal, E.

    The bipolar plates are in weight and volume the major part of the PEM fuel cell stack, and are also a significant contributor to the stack costs. The bipolar plate is therefore a key component if power density has to increase and costs must come down. Three cell plate technologies are expected to reach targeted cost price levels, all having specific advantages and drawbacks. NedStack has developed a conductive composite materials and a production process for fuel cell plates (bipolar and mono-polar). The material has a high electric and thermal conductivity, and can be processed into bipolar plates by a proprietary molding process. Process cycle time has been reduced to less than 10 s, making the material and process suitable for economical mass production. Other development work to increase material efficiency resulted in thin bipolar plates with integrated cooling channels, and integrated seals, and in two-component bipolar plates. Total thickness of the bipolar plates is now less than 3 mm, and will be reduced to 2 mm in the near future. With these thin integrated plates it is possible to increase power density up to 2 kW/l and 2 kW/kg, while at the same time reducing cost by integrating other functions and less material use.

  10. Distinctions of bipolar disorder symptoms in adolescence.

    Science.gov (United States)

    Gudiene, Devika; Leskauskas, Darius; Markeviciūte, Aurelija; Klimavicius, Dalius; Adomaitiene, Virginija

    2008-01-01

    Bipolar disorder in adolescents is a serious mental illness with problematic diagnosis that adversely affects social, academic, emotional, and family functioning. The objective of this study was to analyze features of premorbid and clinical symptoms, comorbidity, and course of bipolar disorder in adolescence. Data for analysis were collected from all case histories (N=6) of 14-18-year-old patients, hospitalized with diagnosis of bipolar disorder in the Unit of Children's and Adolescents' Psychiatry, Department of Psychiatry, Hospital of Kaunas University of Medicine, during the period from 2000 to 2005. Analysis of bipolar disorder course showed that five patients previously had been diagnosed with an episode of depression. The most frequent symptoms typical to bipolar disorder were disobedience and impulsive behavior, rapid changes of mood. The most common premorbid features were frequent changes of mood, being active in communication, hyperactive behavior. Adolescence-onset bipolar disorder was frequently comorbid with emotionally instable personality disorder, borderline type. Findings of the study confirm the notion that oppositional or impulsive behavior, rapid changes of mood without any reason, dysphoric mood and euphoric mood episodes with increased energy were cardinal symptoms of bipolar disorder with mania in adolescents. Most frequent premorbid features of these patients were quite similar to attention-deficit/hyperactivity disorder making differential diagnosis problematic.

  11. Paired structures and bipolar knowledge representation

    DEFF Research Database (Denmark)

    Montero, Javier; Bustince, Humberto; Franco, Camilo

    In this strictly positional paper we propose a general approach to bipolar knowledge representation, where the meaning of concepts can be modelled by examining their decomposition into opposite and neutral categories. In particular, it is the semantic relationship between the opposite categories...... and at the same time the type of neutrality rising in between opposites. Based on this first level of bipolar knowledge representation, paired structures in fact offer the means to characterize a specific bipolar valuation scale depending on the meaning of the concept that has to be verified. In this sense...

  12. Bipolar Disorder and Early Affective Trauma.

    Science.gov (United States)

    de Codt, Aloise; Monhonval, Pauline; Bongaerts, Xavier; Belkacemi, Ikram; Tecco, Juan Martin

    2016-09-01

    Bipolar disorder is a chronic psychiatric disease with a high prevalence and is a major psychosocial and medical burden. The exact etiological pathways of bipolar disorder are not fully understood. Genetic factors are known to play an important role in the etiology of bipolar disorder. However, high rates of discordance among identical twins and a growing body of evidence that environmental factors such as early stress can influence the onset and course of psychiatric diseases underline the importance of additional etiological mechanisms of bipolar disorders. There has been little investigation about early trauma in bipolar disorder. The aim of this study was to review the literature on the association between early traumatic interactions like child neglect, mistreatment, abuse or early parental separation and the occurrence of bipolar disorder in adulthood or impact on the course of the disease. Studies investigating associations between child neglect, mistreatment, abuse or early parental separation and occurrence of bipolar disorder in adulthood or impact on the course of the disease were searched in the Pubmed database. More than 700 articles were sorted independently by two of the authors using predefined criteria. Only research articles, reviews and meta-analyses were selected for this review. 53 articles met the inclusion criteria. To date, four systematic reviews partially addressed our research question. Early trauma is more frequently found in the past of bipolar patients than in the general population. Studies support a harmful effect of childhood trauma on the course of bipolar disease, with more anxious, depressive or psychotic symptoms, an early age of onset and a worse prognosis. Early trauma is more often found in the past of bipolar adult patients than the general population and studies support a harmful effect of childhood trauma on the course of bipolar disease, with more anxious, depressive or psychotic symptoms, an early age of onset and a

  13. Ionizing radiations simulation on bipolar components

    International Nuclear Information System (INIS)

    Montagner, X.

    1999-01-01

    This thesis presents the ionizing radiation effects on bipolar components and more specially their behavior facing the total dose. The first part is devoted to the radiation environments with a special attention to the spatial environments and new emergent environments. The specificities of bipolar components are then presented and their behavior facing the interactions. The physical mechanisms bound to the dose rate are also discussed. The second part presents a physical analysis of degradations induced by the cumulated dosimetry on bipolar components and simulation with the ATLAS code. The third part exposes an electric empirical simulation induced by the cumulated dose in static conditions. (A.L.B.)

  14. Voltammetric studies on the electrochemical determination of methylmercury in chloride medium at carbon microelectrodes

    Energy Technology Data Exchange (ETDEWEB)

    Ribeiro, F. [Centro de Electroquimica e Cinetica da Universidade de Lisboa, Departamento de Quimica e Bioquimica, Faculdade de Ciencias, Universidade de Lisboa, Campo Grande, Ed. C8, 1749-016 Lisbon (Portugal); Neto, M.M.M. [Centro de Electroquimica e Cinetica da Universidade de Lisboa, Departamento de Quimica e Bioquimica, Faculdade de Ciencias, Universidade de Lisboa, Campo Grande, Ed. C8, 1749-016 Lisbon (Portugal) and Departamento de Quimica Agricola e Ambiental, Instituto Superior de Agronomia, Tapada da Ajuda, 1349-017 Lisbon (Portugal)]. E-mail: mm.neto@netcabo.pt; Rocha, M.M. [Centro de Electroquimica e Cinetica da Universidade de Lisboa, Departamento de Quimica e Bioquimica, Faculdade de Ciencias, Universidade de Lisboa, Campo Grande, Ed. C8, 1749-016 Lisbon (Portugal); Fonseca, I.T.E. [Centro de Electroquimica e Cinetica da Universidade de Lisboa, Departamento de Quimica e Bioquimica, Faculdade de Ciencias, Universidade de Lisboa, Campo Grande, Ed. C8, 1749-016 Lisbon (Portugal)

    2006-10-10

    Electroanalytical techniques have been used to determine methylmercury at low levels in environmental matrices. The electrochemical behaviour of methylmercury at carbon microelectrodes in a hydrochloric acid medium using cyclic, square wave and fast-scan linear-sweep voltammetric techniques has been investigated. The analytical utility of the methylmercury reoxidation peak has been explored, but the recorded peak currents were found to be poorly reproducible. This is ascribed to two factors: the adsorption of insoluble chloromercury compounds on the electrode surface, which appears to be an important contribution to hinder the voltammetric signal of methylmercury; and the competition between the reoxidation of the methylmercury radical and its dimerization reaction, which limits the reproducibility of the methylmercury peak. These problems were successfully overcome by adopting the appropriate experimental conditions. Fast-scan rates were employed and an efficient electrochemical regeneration procedure of the electrode surface was achieved, under potentiostatic conditions in a mercury-free solution containing potassium thiocyanate-a strong complexing agent. The influence of chloride ion concentration was analysed. Interference by metals, such as lead and cadmium, was considered. Calibration plots were obtained in the micromolar and submicromolar concentration ranges, allowing the electrochemical determination of methylmercury in trace amounts. An estuarine water sample was analysed using the new method with a glassy carbon microelectrode.

  15. Development and characterization of a voltammetric carbon-fiber microelectrode pH sensor.

    Science.gov (United States)

    Makos, Monique A; Omiatek, Donna M; Ewing, Andrew G; Heien, Michael L

    2010-06-15

    This work describes the development and characterization of a modified carbon-fiber microelectrode sensor capable of measuring real-time physiological pH changes in biological microenvironments. The reagentless sensor was fabricated under ambient conditions from voltammetric reduction of the diazonium salt Fast Blue RR onto a carbon-fiber surface in aprotic media. Fast-scan cyclic voltammetry was used to probe redox activity of the p-quinone moiety of the surface-bound molecule as a function of pH. In vitro calibration of the sensor in solutions ranging from pH 6.5 to 8.0 resulted in a pH-dependent anodic peak potential response. Flow-injection analysis was used to characterize the modified microelectrode, revealing sensitivity to acidic and basic changes discernible to 0.005 pH units. Furthermore, the modified electrode was used to measure dynamic in vivo pH changes evoked during neurotransmitter release in the central nervous system of the microanalytical model organism Drosophila melanogaster.

  16. The impact of multichannel microelectrode recording (MER) in deep brain stimulation of the basal ganglia.

    Science.gov (United States)

    Kinfe, Thomas M; Vesper, Jan

    2013-01-01

    Deep brain stimulation (DBS) of the basal ganglia (Ncl. subthalamicus, Ncl. ventralis intermedius thalami, globus pallidus internus) has become an evidence-based and well-established treatment option in otherwise refractory movement disorders. The Ncl. subthalamicus (STN) is the target of choice in Parkinson's disease.However, a considerable discussion is currently ongoing with regard to the necessity for micro-electrode recording (MER) in DBS surgery.The present review provides an overview on deep brain stimulation and (MER) of the STN in patients with Parkinson's disease. Detailed description is given concerning the multichannel MER systems nowadays available for DBS of the basal ganglia, especially of the STN, as a useful tool for target refinement. Furthermore, an overview is given of the historical aspects, spatial mapping of the STN by MER, and its impact for accuracy and precision in current functional stereotactic neurosurgery.The pros concerning target refinement by MER means on the one hand, and cons including increased bleeding risk, increased operation time, local or general anesthesia, and single versus multichannel microelectrode recording are discussed in detail. Finally, the authors favor the use of MER with intraoperative testing combined with imaging to achieve a more precise electrode placement, aiming to ameliorate clinical outcome in therapy-resistant movement disorders.

  17. Impedance Immunsensor Based on Interdigitated Array Microelectrode and its Experiment Parameter Optimization

    Directory of Open Access Journals (Sweden)

    Wen Ping Zhao

    2014-05-01

    Full Text Available This article accounts for a novel impedance immunosensor based on the specificity reaction of the antigen-antibody and the sensitivity of the interdigitated array microelectrode (IDAM for the determination of chlorpyrifos residues. The basic knowledge of immunoassay was in relation to its IDAM electrode surface modification, antibody immobilization, bovine serum albumin (BSA blocking and sample detection. The SPA was dropped onto the surface of IDAM electrode, used for binding antibody Fc fragments. Next, antibody was immobilized on the SPA modified electrode. Finally, BSA was employed to block the possible remaining active sites avoiding any nonspecific adsorption. Target chlorpyrifos was then captured by the immobilized antibody, resulting in a change in the impedance of the IDAM microelectrode surface. The fabrication procedure of the immunosensor and the sample detection were characterized by electrochemical impedance spectroscopy (EIS. The influences of the experiment parameters were investigated. Under optimized conditions, an excellent biosensor was fabricated. Many of the antibodies, enzymes and other reagents integral to immunoassays were very expensive, often hundreds of dollars per milligram, therefore miniaturization reduces reagent costs drastically. In this article the volume of the reagents was micro upgrade, the antibodies, SPA and BSA were 30 mL, the chlorpyrifos sample and detection solution were 50mL. The advantages of the immunosensor were exhibited in its better specificity, stability, selectivity and regeneration. The proposed method was proven to be a feasible quantitative method for chlorpyrifos analysis in vegetables and fruits.

  18. Microfabrication, characterization and in vivo MRI compatibility of diamond microelectrodes array for neural interfacing.

    Science.gov (United States)

    Hébert, Clément; Warnking, Jan; Depaulis, Antoine; Garçon, Laurie Amandine; Mermoux, Michel; Eon, David; Mailley, Pascal; Omnès, Franck

    2015-01-01

    Neural interfacing still requires highly stable and biocompatible materials, in particular for in vivo applications. Indeed, most of the currently used materials are degraded and/or encapsulated by the proximal tissue leading to a loss of efficiency. Here, we considered boron doped diamond microelectrodes to address this issue and we evaluated the performances of a diamond microelectrode array. We described the microfabrication process of the device and discuss its functionalities. We characterized its electrochemical performances by cyclic voltammetry and impedance spectroscopy in saline buffer and observed the typical diamond electrode electrochemical properties, wide potential window and low background current, allowing efficient electrochemical detection. The charge storage capacitance and the modulus of the electrochemical impedance were found to remain in the same range as platinum electrodes used for standard commercial devices. Finally we observed a reduced Magnetic Resonance Imaging artifact when the device was implanted on a rat cortex, suggesting that boron doped-diamond is a very promising electrode material allowing functional imaging. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. Dual-side and three-dimensional microelectrode arrays fabricated from ultra-thin silicon substrates

    International Nuclear Information System (INIS)

    Du, Jiangang; Masmanidis, Sotiris C; Roukes, Michael L

    2009-01-01

    A method for fabricating planar implantable microelectrode arrays was demonstrated using a process that relied on ultra-thin silicon substrates, which ranged in thickness from 25 to 50 µm. The challenge of handling these fragile materials was met via a temporary substrate support mechanism. In order to compensate for putative electrical shielding of extracellular neuronal fields, separately addressable electrode arrays were defined on each side of the silicon device. Deep reactive ion etching was employed to create sharp implantable shafts with lengths of up to 5 mm. The devices were flip-chip bonded onto printed circuit boards (PCBs) by means of an anisotropic conductive adhesive film. This scalable assembly technique enabled three-dimensional (3D) integration through formation of stacks of multiple silicon and PCB layers. Simulations and measurements of microelectrode noise appear to suggest that low impedance surfaces, which could be formed by electrodeposition of gold or other materials, are required to ensure an optimal signal-to-noise ratio as well a low level of interchannel crosstalk

  20. Voltammetric studies on the electrochemical determination of methylmercury in chloride medium at carbon microelectrodes

    International Nuclear Information System (INIS)

    Ribeiro, F.; Neto, M.M.M.; Rocha, M.M.; Fonseca, I.T.E.

    2006-01-01

    Electroanalytical techniques have been used to determine methylmercury at low levels in environmental matrices. The electrochemical behaviour of methylmercury at carbon microelectrodes in a hydrochloric acid medium using cyclic, square wave and fast-scan linear-sweep voltammetric techniques has been investigated. The analytical utility of the methylmercury reoxidation peak has been explored, but the recorded peak currents were found to be poorly reproducible. This is ascribed to two factors: the adsorption of insoluble chloromercury compounds on the electrode surface, which appears to be an important contribution to hinder the voltammetric signal of methylmercury; and the competition between the reoxidation of the methylmercury radical and its dimerization reaction, which limits the reproducibility of the methylmercury peak. These problems were successfully overcome by adopting the appropriate experimental conditions. Fast-scan rates were employed and an efficient electrochemical regeneration procedure of the electrode surface was achieved, under potentiostatic conditions in a mercury-free solution containing potassium thiocyanate-a strong complexing agent. The influence of chloride ion concentration was analysed. Interference by metals, such as lead and cadmium, was considered. Calibration plots were obtained in the micromolar and submicromolar concentration ranges, allowing the electrochemical determination of methylmercury in trace amounts. An estuarine water sample was analysed using the new method with a glassy carbon microelectrode

  1. Progression along the Bipolar Spectrum: A Longitudinal Study of Predictors of Conversion from Bipolar Spectrum Conditions to Bipolar I and II Disorders

    Science.gov (United States)

    Alloy, Lauren B.; Urošević, Snežana; Abramson, Lyn Y.; Jager-Hyman, Shari; Nusslock, Robin; Whitehouse, Wayne G.; Hogan, Michael

    2011-01-01

    Little longitudinal research has examined progression to more severe bipolar disorders in individuals with “soft” bipolar spectrum conditions. We examine rates and predictors of progression to bipolar I and II diagnoses in a non-patient sample of college-age participants (n = 201) with high General Behavior Inventory scores and childhood or adolescent onset of “soft” bipolar spectrum disorders followed longitudinally for 4.5 years from the Longitudinal Investigation of Bipolar Spectrum (LIBS) project. Of 57 individuals with initial cyclothymia or bipolar disorder not otherwise specified (BiNOS) diagnoses, 42.1% progressed to a bipolar II diagnosis and 10.5% progressed to a bipolar I diagnosis. Of 144 individuals with initial bipolar II diagnoses, 17.4% progressed to a bipolar I diagnosis. Consistent with hypotheses derived from the clinical literature and the Behavioral Approach System (BAS) model of bipolar disorder, and controlling for relevant variables (length of follow-up, initial depressive and hypomanic symptoms, treatment-seeking, and family history), high BAS sensitivity (especially BAS Fun Seeking) predicted a greater likelihood of progression to bipolar II disorder, whereas early age of onset and high impulsivity predicted a greater likelihood of progression to bipolar I (high BAS sensitivity and Fun-Seeking also predicted progression to bipolar I when family history was not controlled). The interaction of high BAS and high Behavioral Inhibition System (BIS) sensitivities also predicted greater likelihood of progression to bipolar I. We discuss implications of the findings for the bipolar spectrum concept, the BAS model of bipolar disorder, and early intervention efforts. PMID:21668080

  2. The thermodynamics of bipolarity: a bifurcation model of bipolar illness and bipolar character and its psychotherapeutic applications.

    Science.gov (United States)

    Sabelli, H C; Carlson-Sabelli, L; Javaid, J I

    1990-11-01

    Two models dominate current formulations of bipolar illness: the homeostatic model implicit in Freud's psychodynamics and most neuroamine deficit/excess theories; and the oscillatory model of exaggerated biological rhythms. The homeostatic model is based on the closed systems approach of classic thermodynamics, while the oscillatory model requires the open systems approach of modern thermodynamics. Here we present a thermodynamic model of bipolarity that includes both homeostatic and oscillatory features and adds the most important feature of open systems thermodynamics: the creation of novel structures in bifurcation processes. According to the proposed model, bipolarity is the result of exaggerated biological energy that augments homeostatic, oscillatory and creative psychological processes. Only low-energy closed systems tend to rest ("point attractor") and entropic disorder. Open processes containing and exchanging energy fluctuate between opposite states ("periodic attractors"); they are characteristic of most physiological rhythms and are exaggerated in bipolar subjects. At higher energies, their strong fluctuations destroy pre-existing patterns and structures, produce turbulence ("chaotic attractors"), which sudden switches between opposite states, and create new and more complex structures. Likewise, high-energy bipolars develop high spontaneity, great fluctuations between opposite moods, internal and interpersonal chaos, and enhanced creativity (personal, artistic, professional) as well as psychopathology (personality deviations, psychotic delusions). Offered here is a theoretical explanation of the dual--creative and destructive--nature of bipolarity in terms of the new enantiodromic concept of entropy generalized by process theory. Clinically, this article offers an integrative model of bipolarity that accounts for many clinical features and contributes to a definition of the bipolar personality.

  3. Bipolar Electrode Sample Preparation Devices

    Science.gov (United States)

    Wang, Yi (Inventor); Song, Hongjun (Inventor); Pant, Kapil (Inventor)

    2017-01-01

    An analyte selection device can include: a body defining a fluid channel having a channel inlet and channel outlet; a bipolar electrode (BPE) between the inlet and outlet; one of an anode or cathode electrically coupled with the BPE on a channel inlet side of the BPE and the other of the anode or cathode electrically coupled with the BPE on a channel outlet side of the BPE; and an electronic system operably coupled with the anode and cathode so as to polarize the BPE. The fluid channel can have any shape or dimension. The channel inlet and channel outlet can be longitudinal or lateral with respect to the longitudinal axis of the channel. The BPE can be any metallic member, such as a flat plate on a wall or mesh as a barrier BPE. The anode and cathode can be located at a position that polarizes the BPE.

  4. Climatic factors and bipolar affective disorder

    DEFF Research Database (Denmark)

    Christensen, Ellen Margrethe; Larsen, Jens Knud; Gjerris, Annette

    2008-01-01

    In bipolar disorder, the factors provoking a new episode are unknown. As a seasonal variation has been noticed, it has been suggested that weather conditions may play a role. The aim of the study was to elucidate whether meteorological parameters influence the development of new bipolar phases....... A group of patients with at least three previous hospitalizations for bipolar disorder was examined every 3 months for up to 3 years. At each examination an evaluation of the affective phase was made according to the Hamilton Depression Scale (HAM-D(17)), and the Bech-Rafaelsen Mania Rating Scale (MAS......). In the same period, daily recordings from the Danish Meteorological Institute were received. We found no correlations between onset of bipolar episodes [defined as MAS score of 11 or more (mania) and as HAM-D(17) score of 12 or more (depression)] and any meteorological parameters. We found a statistical...

  5. Bipolar or unipolar? : A brain teasing question

    NARCIS (Netherlands)

    Rive, M.M.

    2017-01-01

    During the depressed or remitted states, major depressive disorder (MDD) and bipolar disorder (BD) are difficult to distinguish clinically. Treatments for both disorders differ, and inadequate treatment may lead to chronicity, poor psychosocial functioning, or even suicide. Although early

  6. Internet use by patients with bipolar disorder

    DEFF Research Database (Denmark)

    Bauer, Rita; Conell, Jörn; Glenn, Tasha

    2016-01-01

    There is considerable international interest in online education of patients with bipolar disorder, yet little understanding of how patients use the Internet and other sources to seek information. 1171 patients with a diagnosis of bipolar disorder in 17 countries completed a paper-based, anonymous...... survey. 81% of the patients used the Internet, a percentage similar to the general public. Older age, less education, and challenges in country telecommunications infrastructure and demographics decreased the odds of using the Internet. About 78% of the Internet users looked online for information...... on bipolar disorder or 63% of the total sample. More years of education in relation to the country mean, and feeling very confident about managing life decreased the odds of seeking information on bipolar disorder online, while having attended support groups increased the odds. Patients who looked online...

  7. Are rates of pediatric bipolar disorder increasing?

    DEFF Research Database (Denmark)

    Kessing, Lars Vedel; Vradi, Eleni; Andersen, Per Kragh

    2014-01-01

    Studies from the USA suggest that rates of pediatric bipolar disorder have increased since the mid-90s, but no study outside the USA has been published on the rates of pediatric bipolar disorder. Further, it is unclear whether an increase in rates reflects a true increase in the illness or more...... diagnostic attention. Using nationwide registers of all inpatients and outpatients contacts to all psychiatric hospitals in Denmark, we investigated (1) gender-specific rates of incident pediatric mania/bipolar disorder during a period from 1995 to 2012, (2) whether age and other characteristics...... for pediatric mania/bipolar disorder changed during the calendar period (1995 to 2003 versus 2004 to 2012), and (3) whether the diagnosis is more often made at first psychiatric contact in recent time compared to earlier according to gender. Totally, 346 patients got a main diagnosis of a manic episode (F30...

  8. Biological dysrhythm in remitted bipolar I disorder.

    Science.gov (United States)

    Iyer, Aishwarya; Palaniappan, Pradeep

    2017-12-01

    Recent treatment guidelines support treatment of biological rhythm abnormalities as a part of treatment of bipolar disorder, but still, literature examining various domains (Sleep, Activity, Social, and Eating) of biological rhythm and its clinical predictors are less. The main aim of our study is to compare various domains of biological rhythm among remitted bipolar I subjects and healthy controls. We also explored for any association between clinical variables and biological rhythm among bipolar subjects. 40 subjects with Bipolar I disorder and 40 healthy controls who met inclusion and exclusion criteria were recruited for the study. Diagnoses were ascertained by a qualified psychiatrist using MINI 5.0. Sociodemographic details, biological rhythm (BRIAN-Biological Rhythm Interview of assessment in Neuropsychiatry) and Sleep functioning (PSQI- Pittsburgh Sleep Quality Index) were assessed in all subjects. Mean age of the Bipolar subjects and controls were 41.25±11.84years and 38.25±11.25 years respectively. Bipolar subjects experienced more biological rhythm disturbance when compared to healthy controls (total BRIAN score being 34.25±9.36 vs 28.2±6.53) (p=0.002). Subsyndromal depressive symptoms (HDRS) had significant positive correlation with BRIAN global scores(r=0.368, p=0.02). Linear regression analysis showed that number of episodes which required hospitalization (β=0.601, t=3.106, P=0.004), PSQI (β=0.394, t=2.609, p=0.014), HDRS (β=0.376, t=2.34, t=0.036) explained 31% of variance in BRIAN scores in remitted bipolar subjects. Biological rhythm disturbances seem to persist even after clinical remission of bipolar illness. More studies to look into the impact of subsyndromal depressive symptoms on biological rhythm are needed. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Suicide in bipolar disorder: a review.

    Science.gov (United States)

    Latalova, Klara; Kamaradova, Dana; Prasko, Jan

    2014-06-01

    Suicide is a leading cause of death in patients with bipolar disorder. Risk factors and prevention of suicide in this illness are the focus of considerable current research. MEDLINE data base was searched for the key words "bipolar disorder" with "suicide", "lithium" with "suicide", "anticonvulsants" with "bipolar disorder", and "anticonvulsants" with "bipolar disorder" and with "suicide". No language or time constraints were applied. The lists of references were searched manually to find additional articles. It is estimated that 25% to 50% of patients with bipolar disorder will attempt suicide at least once over their lifetime, and that 8% to 19% will complete suicide. Mortality rates from cardiovascular diseases are elevated in bipolar disorder. Risk factors for suicide include younger age of onset of the illness, history of past suicidal behavior, family history of suicide acts, comorbid borderline personality disorder and substance use disorders, and hopelessness. The warning signs calling for immediate action include the patients threatening to harm themselves, or looking for ways to kill themselves (seeking access to pills or weapons), or the patient talking or writing about death. Robust evidence supports the effects of lithium treatment in reducing suicidal attempts and completions in bipolar disorder. The evidence for antisuicidal effects of anticonvulsants is weaker. Nevertheless, valproate and other anticonvulsants are frequently prescribed as mood stabilizers. There have been controversial suggestions that this treatment may elevate the risk of suicide, but the data supporting this are not convincing. Psychoeducation can reduce the number of suicide attempts and completions. Suicide in bipolar disorder is a major public health problem. Recent research has expanded our knowledge of risk factors and warning signs. Nevertheless, it appears that the introduction of lithium treatment in the 1970s was the most recent important breakthrough in the prevention

  10. On-Line Monitoring the Growth of E. coli or HeLa Cells Using an Annular Microelectrode Piezoelectric Biosensor

    Directory of Open Access Journals (Sweden)

    Feifei Tong

    2016-12-01

    Full Text Available Biological information is obtained from the interaction between the series detection electrode and the organism or the physical field of biological cultures in the non-mass responsive piezoelectric biosensor. Therefore, electric parameter of the electrode will affect the biosensor signal. The electric field distribution of the microelectrode used in this study was simulated using the COMSOL Multiphysics analytical tool. This process showed that the electric field spatial distribution is affected by the width of the electrode finger or the space between the electrodes. In addition, the characteristic response of the piezoelectric sensor constructed serially with an annular microelectrode was tested and applied for the continuous detection of Escherichia coli culture or HeLa cell culture. Results indicated that the piezoelectric biosensor with an annular microelectrode meets the requirements for the real-time detection of E. coli or HeLa cells in culture. Moreover, this kind of piezoelectric biosensor is more sensitive than the sensor with an interdigital microelectrode. Thus, the piezoelectric biosensor acts as an effective analysis tool for acquiring online cell or microbial culture information.

  11. Towards on-chip, in-cell recordings from cultured cardiomyocytes by arrays of gold mushroom-shaped microelectrodes

    Directory of Open Access Journals (Sweden)

    Anna eFendyur

    2012-08-01

    Full Text Available Cardiological research greatly rely on the use of cultured primary cardiomyocytes (CM. The prime methodology to assess CM network electrophysiology is based on the use of extracellular recordings by substrate-integrated planar Micro-Electrode Arrays (MEAs. Whereas this methodology permits simultaneous, long-term monitoring of the CM electrical activity, it limits the information to extracellular field potentials (FP. The alternative method of intracellular action potentials (AP recordings by sharp- or patch-microelectrodes is limited to a single cell at a time. Here, we began to merge the advantages of planar MEA and intracellular microelectrodes. To that end we cultured rat CM on micrometer size protruding gold mushroom-shaped microelectrode (gMµE arrays. Cultured CMs engulf the gMµE permitting FPs recordings from individual cells. Local electroporation of a CM converts the extracellular recording configuration to attenuated intracellular APs with shape and duration similar to those recorded intracellularly. The procedure enables to simultaneously record APs from an unlimited number of CMs. The electroporated membrane spontaneously recovers. This allows for repeated recordings from the same CM a number of times (>8 for over 10 days. The further development of CM-gMµE configuration opens up new venues for basic and applied biomedical research.

  12. Further Evaluation of DNT Hazard Screening using Neural Networks from Rat Cortical Neurons on Multi-well Microelectrode Arrays

    Science.gov (United States)

    Thousands of chemicals have not been characterized for their DNT potential. Due to the need for DNT hazard identification, efforts to develop screening assays for DNT potential is a high priority. Multi-well microelectrode arrays (MEA) measure the spontaneous activity of electr...

  13. On-Line Monitoring the Growth of E. coli or HeLa Cells Using an Annular Microelectrode Piezoelectric Biosensor.

    Science.gov (United States)

    Tong, Feifei; Lian, Yan; Han, Junliang

    2016-12-18

    Biological information is obtained from the interaction between the series detection electrode and the organism or the physical field of biological cultures in the non-mass responsive piezoelectric biosensor. Therefore, electric parameter of the electrode will affect the biosensor signal. The electric field distribution of the microelectrode used in this study was simulated using the COMSOL Multiphysics analytical tool. This process showed that the electric field spatial distribution is affected by the width of the electrode finger or the space between the electrodes. In addition, the characteristic response of the piezoelectric sensor constructed serially with an annular microelectrode was tested and applied for the continuous detection of Escherichia coli culture or HeLa cell culture. Results indicated that the piezoelectric biosensor with an annular microelectrode meets the requirements for the real-time detection of E. coli or HeLa cells in culture. Moreover, this kind of piezoelectric biosensor is more sensitive than the sensor with an interdigital microelectrode. Thus, the piezoelectric biosensor acts as an effective analysis tool for acquiring online cell or microbial culture information.

  14. Evaluation of the Neuroactivity of ToxCast Compounds Using Multi-well Microelectrode Array Recordings in Primary Cortical Neurons

    Science.gov (United States)

    Evaluation of the Neuroactivity of ToxCast Compounds Using Multi-well Microelectrode Array Recordings in Primary Cortical Neurons P Valdivia1, M Martin2, WR LeFew3, D Hall3, J Ross1, K Houck2 and TJ Shafer3 1Axion Biosystems, Atlanta GA and 2NCCT, 3ISTD, NHEERL, ORD, US EPA, RT...

  15. Preparation of bipolar membranes by electrospinning

    International Nuclear Information System (INIS)

    Pan, Jiefeng; Hou, Linxiao; Wang, Qiuyue; He, Yubin; Wu, Liang; Mondal, Abhishek N.; Xu, Tongwen

    2017-01-01

    A new preparative pathway for the bipolar membranes was initiated via the electrospinning and hot-press process. The prepared bipolar membrane was consisting of sulfonated poly (phenylene oxide), polyethylene glycol, and quaternized poly (phenylene oxide). The above mentioned membrane was fabricated by the continuous electrospinning of the respective layer, followed by the solvent atmosphere treatment and hot-pressing, to obtain a transparent and dense structure. The thickness of each layer can be easily tuned by controlling the electrospinning parameters. The clear interfacial structure was observed and confirmed by the scanning electron microscope. The bipolar performance is evaluated by the current–voltage curves and production yield of acid and base. The final optimized bipolar membrane had similar yield of acid and base as the casting membrane. However, extremely lower potential drop value was observed when they are applied for the production of acid and base. The experimental results showed that, electrospinning is an effective and well controlled way to fabricate bipolar membranes, in which anion or cation exchange layer as well as interfacial layer can be easily changed or added as requested. - Highlights: • Bipolar membranes were prepared through electrospinning followed by post-treatment. • As-prepared membranes were successfully applied in electrodialysis for production of acid and base. • Electrospun membranes exhibit better performance than the casting ones.

  16. Preparation of bipolar membranes by electrospinning

    Energy Technology Data Exchange (ETDEWEB)

    Pan, Jiefeng; Hou, Linxiao; Wang, Qiuyue; He, Yubin; Wu, Liang; Mondal, Abhishek N.; Xu, Tongwen, E-mail: twxu@ustc.edu.cn

    2017-01-15

    A new preparative pathway for the bipolar membranes was initiated via the electrospinning and hot-press process. The prepared bipolar membrane was consisting of sulfonated poly (phenylene oxide), polyethylene glycol, and quaternized poly (phenylene oxide). The above mentioned membrane was fabricated by the continuous electrospinning of the respective layer, followed by the solvent atmosphere treatment and hot-pressing, to obtain a transparent and dense structure. The thickness of each layer can be easily tuned by controlling the electrospinning parameters. The clear interfacial structure was observed and confirmed by the scanning electron microscope. The bipolar performance is evaluated by the current–voltage curves and production yield of acid and base. The final optimized bipolar membrane had similar yield of acid and base as the casting membrane. However, extremely lower potential drop value was observed when they are applied for the production of acid and base. The experimental results showed that, electrospinning is an effective and well controlled way to fabricate bipolar membranes, in which anion or cation exchange layer as well as interfacial layer can be easily changed or added as requested. - Highlights: • Bipolar membranes were prepared through electrospinning followed by post-treatment. • As-prepared membranes were successfully applied in electrodialysis for production of acid and base. • Electrospun membranes exhibit better performance than the casting ones.

  17. Comorbidity bipolar disorder and personality disorders.

    Science.gov (United States)

    Latalova, Klara; Prasko, Jan; Kamaradova, Dana; Sedlackova, Jana; Ociskova, Marie

    2013-01-01

    Outcome in bipolar patients can be affected by comorbidity of other psychiatric disorders. Comorbid personality disorders are frequent and may complicate the course of bipolar illness. We have much information about treating patients with uncomplicated bipolar disorder (BD) but much less knowledge about possibilities for patients with the comorbidity of BD and personality disorder. We conducted a series of literature searches using, as key words or as items in indexed fields, bipolar disorder and personality disorder or personality traits. Articles were obtained by searching MEDLINE from 1970 to 2012. In addition, we used other papers cited in articles from these searches, or cited in articles used in our own work. Tests of personality traits indicated that euthymic bipolar patients have higher scores on harm avoidance, reward dependence, and novelty seeking than controls. Elevation of novelty seeking in bipolar patients is associated with substance abuse comorbidity. Comorbidity with personality disorders in BD patients is associated with a more difficult course of illness (such as longer episodes, shorter time euthymic, and earlier age at onset) and an increase in comorbid substance abuse, suicidality and aggression. These problems are particularly pronounced in comorbidity with borderline personality disorder. Comorbidity with antisocial personality disorder elicits a similar spectrum of difficulties; some of the antisocial behavior exhibited by patients with this comorbidity is mediated by increased impulsivity.

  18. The role of sleep in bipolar disorder

    Directory of Open Access Journals (Sweden)

    Gold AK

    2016-06-01

    Full Text Available Alexandra K Gold,1 Louisa G Sylvia,1,2 1Department of Psychiatry, Massachusetts General Hospital, 2Harvard Medical School, Boston, MA, USA Abstract: Bipolar disorder is a serious mental illness characterized by alternating periods of elevated and depressed mood. Sleep disturbances in bipolar disorder are present during all stages of the condition and exert a negative impact on overall course, quality of life, and treatment outcomes. We examine the partnership between circadian system (process C functioning and sleep–wake homeostasis (process S on optimal sleep functioning and explore the role of disruptions in both systems on sleep disturbances in bipolar disorder. A convergence of evidence suggests that sleep problems in bipolar disorder result from dysregulation across both process C and process S systems. Biomarkers of depressive episodes include heightened fragmentation of rapid eye movement (REM sleep, reduced REM latency, increased REM density, and a greater percentage of awakenings, while biomarkers of manic episodes include reduced REM latency, greater percentage of stage I sleep, increased REM density, discontinuous sleep patterns, shortened total sleep time, and a greater time awake in bed. These findings highlight the importance of targeting novel treatments for sleep disturbance in bipolar disorder. Keywords: bipolar disorder, circadian rhythms, sleep–wake homeostasis

  19. Classification of cognitive performance in bipolar disorder.

    Science.gov (United States)

    Sparding, Timea; Silander, Katja; Pålsson, Erik; Östlind, Josefin; Ekman, Carl Johan; Sellgren, Carl M; Joas, Erik; Hansen, Stefan; Landén, Mikael

    2017-09-01

    To understand the etiology of cognitive impairment associated with bipolar disorder, we need to clarify potential heterogeneity in cognitive functioning. To this end, we used multivariate techniques to study if the correlation structure of cognitive abilities differs between persons with bipolar disorder and controls. Clinically stable patients with bipolar disorder (type I: n = 64; type II: n = 44) and healthy controls (n = 86) were assessed with a wide range of cognitive tests measuring executive function, speed, memory, and verbal skills. Data were analysed with multivariate techniques. A distinct subgroup (∼30%) could be identified that performed significantly poorer on tests concerning memory function. This cognitive phenotype subgroup did not differ from the majority of bipolar disorder patients with respect to other demographic or clinical characteristics. Whereas the majority of patients performed similar to controls, a subgroup of patients with bipolar disorder differed substantially from healthy controls in the correlation pattern of low-level cognitive abilities. This suggests that cognitive impairment is not a general trait in bipolar disorder but characteristic of a cognitive subgroup. This has important clinical implications for cognitive rehabilitation and remediation.

  20. O transtorno bipolar na mulher Bipolar disorder in women

    Directory of Open Access Journals (Sweden)

    Alexandro de Borja Gonçalves Guerra

    2005-01-01

    Full Text Available Diferenças sexuais, descritas em vários transtornos psiquiátricos, também parecem estar presentes no transtorno afetivo bipolar (TAB. A prevalência do TAB tipo I se distribui igualmente entre mulheres e homens. Mulheres parecem estar sujeitas a um risco maior de ciclagem rápida e mania mista, condições que fariam do TAB um transtorno com curso mais prejudicial no sexo feminino. Uma diátese depressiva mais marcante, uso excessivo de antidepressivos e diferenças hormonais surgem como hipóteses para explicar essas diferenças fenomenológicas, apesar das quais, mulheres e homens parecem responder igualmente ao tratamento medicamentoso. A indicação de anticonvulsivantes como primeira escolha em mulheres é controversa, a não ser para o tratamento da mania mista e, talvez, da ciclagem rápida. O tratamento do TAB na gravidez deve levar em conta tanto os riscos de exposição aos medicamentos quanto à doença materna. A profilaxia do TAB no puerpério está fortemente indicada em decorrência do grande risco de recorrência da doença nesse período. Embora, de modo geral, as medicações psicotrópicas estejam contra-indicadas durante a amamentação, entre os estabilizadores do humor, a carbamazepina e o valproato são mais seguros do que o lítio. Mais estudos são necessários para a confirmação das diferenças de curso do TAB entre mulheres e homens e a investigação de possíveis diferenças na efetividade dos tratamentos.Gender differences, described in several psychiatric disorders, seem to be also present in bipolar disorder (BD. The prevalence of bipolar I disorder is equally distributed between women and men. Women seem to be at higher risk for rapid cycling and mixed mania, conditions that could make BD a disorder with a more severe course in the female sex. A marked depressive diathesis among women, greatest use of antidepressants and hormonal differences have been mentioned as hypotheses to explain these

  1. Quantitative Analysis of Rat Dorsal Root Ganglion Neurons Cultured on Microelectrode Arrays Based on Fluorescence Microscopy Image Processing.

    Science.gov (United States)

    Mari, João Fernando; Saito, José Hiroki; Neves, Amanda Ferreira; Lotufo, Celina Monteiro da Cruz; Destro-Filho, João-Batista; Nicoletti, Maria do Carmo

    2015-12-01

    Microelectrode Arrays (MEA) are devices for long term electrophysiological recording of extracellular spontaneous or evocated activities on in vitro neuron culture. This work proposes and develops a framework for quantitative and morphological analysis of neuron cultures on MEAs, by processing their corresponding images, acquired by fluorescence microscopy. The neurons are segmented from the fluorescence channel images using a combination of segmentation by thresholding, watershed transform, and object classification. The positioning of microelectrodes is obtained from the transmitted light channel images using the circular Hough transform. The proposed method was applied to images of dissociated culture of rat dorsal root ganglion (DRG) neuronal cells. The morphological and topological quantitative analysis carried out produced information regarding the state of culture, such as population count, neuron-to-neuron and neuron-to-microelectrode distances, soma morphologies, neuron sizes, neuron and microelectrode spatial distributions. Most of the analysis of microscopy images taken from neuronal cultures on MEA only consider simple qualitative analysis. Also, the proposed framework aims to standardize the image processing and to compute quantitative useful measures for integrated image-signal studies and further computational simulations. As results show, the implemented microelectrode identification method is robust and so are the implemented neuron segmentation and classification one (with a correct segmentation rate up to 84%). The quantitative information retrieved by the method is highly relevant to assist the integrated signal-image study of recorded electrophysiological signals as well as the physical aspects of the neuron culture on MEA. Although the experiments deal with DRG cell images, cortical and hippocampal cell images could also be processed with small adjustments in the image processing parameter estimation.

  2. Clinical, Demographic, and Familial Correlates of Bipolar Spectrum Disorders among Offspring of Parents with Bipolar Disorder

    Science.gov (United States)

    Goldstein, Benjamin I.; Shamseddeen, Wael; Axelson, David A.; Kalas, Cathy; Monk, Kelly; Brent, David A.; Kupfer, David J.; Birmaher, Boris

    2010-01-01

    Objective: Despite increased risk, most offspring of parents with bipolar disorder (BP) do not manifest BP. The identification of risk factors for BP among offspring could improve preventive and treatment strategies. We examined this topic in the Pittsburgh Bipolar Offspring Study (BIOS). Method: Subjects included 388 offspring, ages 7-17 years,…

  3. [Circadian markers and genes in bipolar disorder].

    Science.gov (United States)

    Yeim, S; Boudebesse, C; Etain, B; Belliviera, F

    2015-09-01

    Bipolar disorder is a severe and complex multifactorial disease, characterized by alternance of acute episodes of depression and mania/hypomania, interspaced by euthymic periods. The etiological determinants of bipolar disorder yet, are still poorly understood. For the last 30 years, chronobiology is an important field of investigation to better understand the pathophysiology of bipolar disorder. We conducted a review using Medline, ISI Database, EMBase, PsyInfo up to January 2015, using the following keywords combinations: "mood disorder", "bipolar disorder", "depression", "unipolar disorder", "major depressive disorder", "affective disorder", for psychiatric conditions; and "circadian rhythms", "circadian markers", "circadian gene", "clock gene", "melatonin" for circadian rhythms. The search critera was presence of word in any field of the article. Quantitative and qualitative circadian abnormalities are associated with bipolar disorders both during acute episodes and euthymic periods, suggesting that these altered circadian rhythms may represent biological trait markers of the disorder. These circadian dysfunctions were assessed by various validated tools including polysomnography, actigraphy, sleep diaries, chronotype assessments and blood melatonin/cortisol measures. Other altered endogenous circadian activities have also been reported in bipolar patients, such as hormones secretion, core body temperature or fibroblasts activity. Moreover, these markers were also altered in healthy relatives of bipolar patients, suggesting a degree of heritability. Several genetic association studies have also showed associations between multiple circadian genes and bipolar disorder, such as CLOCK, ARTNL1, GSK3β, PER3, NPAS2, NR1D1, TIMELESS, RORA, RORB, and CSNK1ε. Thus, these circadian gene variants may contribute to the genetic susceptibility of the disease. Furthermore, the study of the clock system may help to better understand some phenotypic aspects like the

  4. Decision making in euthymic bipolar I and bipolar II disorders.

    Science.gov (United States)

    Martino, D J; Strejilevich, S A; Torralva, T; Manes, F

    2011-06-01

    The main aim of this study was to compare a large population of patients with bipolar disorder (BD) types I and II strictly defined as euthymic with healthy controls on measures of decision making. An additional aim was to compare performance on a decision-making task between patients with and without a history of suicide attempt. Eighty-five euthymic patients with BD-I or BD-II and 34 healthy controls were included. All subjects completed tests to assess verbal memory, attention and executive functions, and a decision-making paradigm (the Iowa Gambling Task, IGT). Both groups of patients had worse performance than healthy controls on measures of verbal memory, attention and executive function. No significant differences were found between BD-I, BD-II and healthy controls on measures of decision making. By contrast, patients with a history of suicide attempt had lower performance in the IGT than patients without a history of suicide attempt. Patients with euthymic BD-I and BD-II had intact decision-making abilities, suggesting that this does not represent a reliable trait marker of the disorder. In addition, our results provide further evidence of an association between impairments in decision making and vulnerability to suicidal behavior.

  5. Note: Microelectrode-shielding tip for scanning probe electron energy spectroscopy

    Science.gov (United States)

    Huang, Wei; Li, Zhean; Xu, Chunkai; Liu, Jian; Xu, Chunye; Chen, Xiangjun

    2018-04-01

    We report a novel microelectrode-shielding tip (ME tip) for scanning probe electron energy spectroscopy (SPEES). The shielding effect of this tip is studied through comparing the detection efficiency with the normal tip by both experiment and simulation. The results show that the backscattering count rate detected by the SPEES instrument using the normal tip begins to decrease as the tip approaches to the sample surface within 21 μm, while that using the ME tip only starts to drop off within 1 μm. This indicates that the electron energy spectra can be measured with the ME tip at a much closer tip-sample distance. Furthermore, it is also demonstrated that the ME tip can be used to obtain topography of the sample surface in situ simultaneously.

  6. Microelectrode generator-collector systems for electrolytic titration: theoretical and practical considerations.

    Science.gov (United States)

    Bell, Christopher G; Seelanan, Parinya; O'Hare, Danny

    2017-10-23

    Electochemical generator-collector systems, where one electrode is used to generate a reagent, have a potentially large field of application in sensing and measurement. We present a new theoretical description for coplanar microelectrode disc-disc systems where the collector is passive (such as a potentiometric sensor) and the generator is operating at constant flux. This solution is then used to develop a leading order solution for such a system where the reagent reacts reversibly in solution, such as in acid-base titration, where a hydrogen ion flux is generated by electrolysis of water. The principal novel result of the theory is that such devices are constrained by a maximum reagent flux. The hydrogen ion concentration at the collector will only reflect the buffer capacity of the bulk solution if this constraint is met. Both mathematical solutions are evaluated with several microfabricated devices and reasonable agreement with theory is demonstrated.

  7. Characterization of poly(3,4-ethylenedioxythiophene):tosylate conductive polymer microelectrodes for transmitter detection

    DEFF Research Database (Denmark)

    Larsen, Simon T.; Vreeland, Richard F.; Heien, Michael L.

    2012-01-01

    applications such as capillary electrophoresis, high-performance liquid chromatography, and constant potential amperometry at living cells. Band electrodes with widths down to 3 μm were fabricated on polymer substrates using UV lithographic methods. The electrodes are electrochemically stable in a range......In this paper we investigate the physical and electrochemical properties of micropatterned poly(3,4-ethylenedioxythiophene):tosylate (PEDOT:tosylate) microelectrodes for neurochemical detection. PEDOT:tosylate is a promising conductive polymer electrode material for chip-based bioanalytical...... between −200 mV and 700 mV vs. Ag/AgCl and show a relatively low resistance. A wide range of transmitters is shown to oxidize readily on the electrodes. Kinetic rate constants and half wave potentials are reported. The capacitance per area was found to be high (1670 ± 130 μF cm−2) compared to other thin...

  8. Microelectrode-assisted low-voltage atmospheric pressure glow discharge in air

    Science.gov (United States)

    Liu, Wenzheng; Zhao, Shuai; Niu, Jiangqi; Chai, Maolin

    2017-09-01

    During the process of discharge, appropriately changing the paths corresponding to electric field lines and the field strength distribution along these paths, as well as increasing the number of initial electrons, can effectively enhance the uniformity of discharge and inhibit the formation of filamentary discharge. A method is proposed that uses a microelectrode to initiate the macroscopic discharge phenomenon. An asymmetric structure was designed comprising a single electrode of carbon fiber; this electrode structure is of helical-contact type. Benefitting from the special electric field distribution and the microdischarge process, a three-dimensional atmospheric pressure glow discharge was achieved in air, characterized by low discharge voltage, low energy consumption, good diffusion performance, and less ozone generation. The plasma studied is uniform and stable with good diffusion characteristics and low levels of contaminants and hence has potential applications in the field of air purification.

  9. Doped Overoxidized Polypyrrole Microelectrodes as Sensors for the Detection of Dopamine Released from Cell Populations

    DEFF Research Database (Denmark)

    Sasso, Luigi; Heiskanen, Arto; Diazzi, Francesco

    2013-01-01

    A surface modification of interdigitated gold microelectrodes (IDEs) with a doped polypyrrole (PPy) film for detection of dopamine released from populations of differentiated PC12 cells is presented. A thin PPy layer was potentiostatically electropolymerized from an 10 aqueous pyrrole solution onto...... electrode surfaces. The conducting polymer film was doped during electropolymerization by introducing counter ions in the monomer solution. Several counter ions were tested and the resulting electrode modifications were characterized electrochemically to find the optimal dopant that increases sensitivity...... to amperometrically detect dopamine released by populations of cells upon triggering cellular exocytosis with an elevated K+ concentration. A comparison between the generated current on bare gold electrodes and gold electrodes modified with overoxidized doped PPy illustrates the clear advantage of the modification...

  10. Hydrogen Peroxide Impedimetric Detection on Poly-Ortho-Phenylenediamine Modified Platinum Disk Microelectrode

    International Nuclear Information System (INIS)

    Zainiharyati Mohd Zain; Norazreen Zakaria

    2014-01-01

    This work describes the development of hydrogen peroxide detection based on Poly-ortho-phenylenediamine modified Platinum disk microelectrode (50 μm in diameter). The electrochemical performances of H 2 O 2 detection were studied using Chronoamperometry, Cyclic Voltammetry (CV) and Electrochemical Impedance Spectroscopy (EIS) techniques in Phosphate Buffer Solution (PBS) pH 7.4. Effect of potential, electrode size, and various concentrations of H 2 O 2 , among others, were investigated by tracking the impedance changes at a specific perturbation frequency. To obtain the Charge transfer resistance (R ct ) values, a modified Randles Equivalent Circuit was modelled and fitted to Nyquist Plot. Then, this sensor was further applied in the detection of H 2 O 2 in antiseptic mouthwash with percent recovery of 97 % ± 0.14 (x10 3 kΩ). (author)

  11. A Multimodal, SU-8 - Platinum - Polyimide Microelectrode Array for Chronic In Vivo Neurophysiology.

    Directory of Open Access Journals (Sweden)

    Gergely Márton

    Full Text Available Utilization of polymers as insulator and bulk materials of microelectrode arrays (MEAs makes the realization of flexible, biocompatible sensors possible, which are suitable for various neurophysiological experiments such as in vivo detection of local field potential changes on the surface of the neocortex or unit activities within the brain tissue. In this paper the microfabrication of a novel, all-flexible, polymer-based MEA is presented. The device consists of a three dimensional sensor configuration with an implantable depth electrode array and brain surface electrodes, allowing the recording of electrocorticographic (ECoG signals with laminar ones, simultaneously. In vivo recordings were performed in anesthetized rat brain to test the functionality of the device under both acute and chronic conditions. The ECoG electrodes recorded slow-wave thalamocortical oscillations, while the implanted component provided high quality depth recordings. The implants remained viable for detecting action potentials of individual neurons for at least 15 weeks.

  12. Microelectrode Arrays and the Use of PEG-Functionalized Diblock Copolymer Coatings

    Directory of Open Access Journals (Sweden)

    Sakshi Uppal

    2014-09-01

    Full Text Available PEG-modified diblock copolymer surfaces have been examined for their compatibility with microelectrode array based analytical methods. The use of PEG-modified polymer surfaces on the arrays was initially problematic because the redox couples used in the experiments were adsorbed by the polymer. This led the current measured by cyclic voltammetry for the redox couple to be unstable and increase with time. However, two key findings allow the experiments to be successful. First, after multiple cyclic voltammograms the current associated with the redox couple does stabilize so that a good baseline current can be established. Second, the rate at which the current stabilizes is consistent every time a particular coated array is used. Hence, multiple analytical experiments can be conducted on an array coated with a PEG-modified diblock copolymer and the data obtained is comparable as long as the data for each experiment is collected at a consistent time point.

  13. Purification of carbon nanotubes through an electric field near the arranged microelectrodes

    International Nuclear Information System (INIS)

    Shim, Hyung Cheoul; Lee, Hyung Woo; Yeom, Sujin; Kwak, Yoon Keun; Lee, Seung S; Kim, Soo Hyun

    2007-01-01

    In this work, we attempt to purify multi-walled carbon nanotubes (MWNTs) using electrophoresis induced by the application of an AC electric field to a set of microelectrodes in a microliquid channel. This purifying method is different from conventional methods based on chemical processes. It was observed that most of the MWNTs could pass along the microliquid channel without attaching to the electrode under specific conditions of 1 kHz, at 0.2 V rms μm -1 . On the other hand, the majority of the carbon impurities attached to the electrodes under identical conditions. Field emission scanning electron microscopy (FESEM) images and Raman spectra confirm that this condition is beneficial for removing carbon impurities. The proposed approach has potential applicability in the development of microdevices that can simultaneously perform the purification and fabrication of MWNTs

  14. Addressing of LnCaP Cell Using Magnetic Particles Assisted Impedimetric Microelectrode.

    Science.gov (United States)

    Nguyen, Dung Thi Xuan; Tran, Trong Binh; Nguyen, Phuong-Diem; Min, Junhong

    2016-03-01

    In this study, we provide a facile, effective technique for a simple isolation and enrichment of low metastatic prostate tumor cell LNCaP using biocompatible, magnetic particles asissted impedimetric sensing system. Hydrophobic cell membrane anchors (BAM) were generated onto magnetic particles which diameters vary from 50 nm to 5 μm and were used to capture LNCaP cells from the suspension. Finally, magnetic particle-LNCaP complex were addressed onto the surface of the interdigitated microelectrode (IDM). Cell viability was monitored by our laboratory developed-technique Electrical Cell Substrate Impedance Sensing (ECIS). The results reavealed that 50 nm-magnetic particles showed best performance in terms of cell separation and cell viability. This technique provides a simple and efficient method for the direct addressing of LNCaP cell on the surface and enhances better understanding of cell behavior for cancer management in the near future.

  15. The International Society for Bipolar Disorders (ISBD) Task Force Report on Antidepressant Use in Bipolar Disorders

    Science.gov (United States)

    Pacchiarotti, Isabella; Bond, David J.; Baldessarini, Ross J.; Nolen, Willem A.; Grunze, Heinz; Licht, Rasmus W.; Post, Robert M.; Berk, Michael; Goodwin, Guy M.; Sachs, Gary S.; Tondo, Leonardo; Findling, Robert L.; Youngstrom, Eric A.; Tohen, Mauricio; Undurraga, Juan; González-Pinto, Ana; Goldberg, Joseph F.; Yildiz, Ayşegül; Altshuler, Lori L.; Calabrese, Joseph R.; Mitchell, Philip B.; Thase, Michael E.; Koukopoulos, Athanasios; Colom, Francesc; Frye, Mark A.; Malhi, Gin S.; Fountoulakis, Konstantinos N.; Vázquez, Gustavo; Perlis, Roy H.; Ketter, Terence A.; Cassidy, Frederick; Akiskal, Hagop; Azorin, Jean-Michel; Valentí, Marc; Mazzei, Diego Hidalgo; Lafer, Beny; Kato, Tadafumi; Mazzarini, Lorenzo; Martínez-Aran, Anabel; Parker, Gordon; Souery, Daniel; Özerdem, Ayşegül; McElroy, Susan L.; Girardi, Paolo; Bauer, Michael; Yatham, Lakshmi N.; Zarate, Carlos A.; Nierenberg, Andrew A.; Birmaher, Boris; Kanba, Shigenobu; El-Mallakh, Rif S.; Serretti, Alessandro; Rihmer, Zoltan; Young, Allan H.; Kotzalidis, Georgios D.; MacQueen, Glenda M.; Bowden, Charles L.; Ghaemi, S. Nassir; Lopez-Jaramillo, Carlos; Rybakowski, Janusz; Ha, Kyooseob; Perugi, Giulio; Kasper, Siegfried; Amsterdam, Jay D.; Hirschfeld, Robert M.; Kapczinski, Flávio; Vieta, Eduard

    2014-01-01

    Objective The risk-benefit profile of antidepressant medications in bipolar disorder is controversial. When conclusive evidence is lacking, expert consensus can guide treatment decisions. The International Society for Bipolar Disorders (ISBD) convened a task force to seek consensus recommendations on the use of antidepressants in bipolar disorders. Method An expert task force iteratively developed consensus through serial consensus-based revisions using the Delphi method. Initial survey items were based on systematic review of the literature. Subsequent surveys included new or reworded items and items that needed to be rerated. This process resulted in the final ISBD Task Force clinical recommendations on antidepressant use in bipolar disorder. Results There is striking incongruity between the wide use of and the weak evidence base for the efficacy and safety of antidepressant drugs in bipolar disorder. Few well-designed, long-term trials of prophylactic benefits have been conducted, and there is insufficient evidence for treatment benefits with antidepressants combined with mood stabilizers. A major concern is the risk for mood switch to hypomania, mania, and mixed states. Integrating the evidence and the experience of the task force members, a consensus was reached on 12 statements on the use of antidepressants in bipolar disorder. Conclusions Because of limited data, the task force could not make broad statements endorsing antidepressant use but acknowledged that individual bipolar patients may benefit from antidepressants. Regarding safety, serotonin reuptake inhibitors and bupropion may have lower rates of manic switch than tricyclic and tetracyclic antidepressants and norepinephrine-serotonin reuptake inhibitors. The frequency and severity of antidepressant-associated mood elevations appear to be greater in bipolar I than bipolar II disorder. Hence, in bipolar I patients antidepressants should be prescribed only as an adjunct to mood-stabilizing medications

  16. Unsupervised neural spike sorting for high-density microelectrode arrays with convolutive independent component analysis.

    Science.gov (United States)

    Leibig, Christian; Wachtler, Thomas; Zeck, Günther

    2016-09-15

    Unsupervised identification of action potentials in multi-channel extracellular recordings, in particular from high-density microelectrode arrays with thousands of sensors, is an unresolved problem. While independent component analysis (ICA) achieves rapid unsupervised sorting, it ignores the convolutive structure of extracellular data, thus limiting the unmixing to a subset of neurons. Here we present a spike sorting algorithm based on convolutive ICA (cICA) to retrieve a larger number of accurately sorted neurons than with instantaneous ICA while accounting for signal overlaps. Spike sorting was applied to datasets with varying signal-to-noise ratios (SNR: 3-12) and 27% spike overlaps, sampled at either 11.5 or 23kHz on 4365 electrodes. We demonstrate how the instantaneity assumption in ICA-based algorithms has to be relaxed in order to improve the spike sorting performance for high-density microelectrode array recordings. Reformulating the convolutive mixture as an instantaneous mixture by modeling several delayed samples jointly is necessary to increase signal-to-noise ratio. Our results emphasize that different cICA algorithms are not equivalent. Spike sorting performance was assessed with ground-truth data generated from experimentally derived templates. The presented spike sorter was able to extract ≈90% of the true spike trains with an error rate below 2%. It was superior to two alternative (c)ICA methods (≈80% accurately sorted neurons) and comparable to a supervised sorting. Our new algorithm represents a fast solution to overcome the current bottleneck in spike sorting of large datasets generated by simultaneous recording with thousands of electrodes. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Impedimetric microbial biosensor based on single wall carbon nanotube modified microelectrodes for trichloroethylene detection

    International Nuclear Information System (INIS)

    Hnaien, M.; Bourigua, S.; Bessueille, F.; Bausells, J.; Errachid, A.; Lagarde, F.; Jaffrezic-Renault, N.

    2011-01-01

    Highlights: ► We propose an impedimetric microbial biosensor for trichloroethylene detection. ► A new transducer modified with carbon nanotubes and Pseudomonas putida is evaluated. ► Functionalization steps are controlled by impedance spectroscopy and AFM. ► The biosensor offers good sensitivity, selectivity, linear range and stability. ► The biosensor is successfully applied to spiked natural water samples. - Abstract: Contamination of soils and groundwaters with persistent organic pollutants is a matter of increasing concern. The most common organic pollutants are chlorinated hydrocarbons such as perchloroethylene and trichloroethylene (TCE). In this study, we developed a bacterial impedimetric biosensor for TCE detection, based on the immobilization of Pseudomonas putida F1 strain on gold microelectrodes functionalized with single wall carbon nanotubes covalently linked to anti-Pseudomonas antibodies. The different steps of microelectrodes functionalization were characterized by electrochemical impedance and atomic force spectroscopies, and analytical performances of the developed microbial biosensor were determined. The impedimetric biosensor response was linear with TCE concentration up to 150 μg L −1 and a low limit of detection (20 μg L −1 ) was achieved. No significant loss of signal was observed after 4 weeks of storage at 4 °C in phosphate buffer saline pH 7 (three to four measurements a week). After 5 weeks, 90% of the initial value still remained. cis-1,2-Dichloroethylene and vinylchloride, the main TCE degradation products, did not significantly interfere with TCE. The microbial sensor was finally applied to the determination of TCE in natural water samples spiked at the 30, 50 and 75 μg L −1 levels. Recoveries were very good, ranging from 100 to 103%.

  18. Lower layers in the motor cortex are more effective targets for penetrating microelectrodes in cortical prostheses

    Science.gov (United States)

    Parikh, Hirak; Marzullo, Timothy C.; Kipke, Daryl R.

    2009-04-01

    Improving cortical prostheses requires the development of recording neural interfaces that are efficient in terms of providing maximal control information with minimal interface complexity. While the typical approaches have targeted neurons in the motor cortex with multiple penetrating shanks, an alternative approach is to determine an efficient distribution of electrode sites within the layers of the cortex with fewer penetrating shanks. The objective of this study was to compare unit activity in the upper and lower layers of the cortex with respect to movement and direction in order to inform the design of penetrating microelectrodes. Four rats were implanted bilaterally with multi-site single-shank silicon microelectrode arrays in the neck/shoulder region of the motor cortex. We simultaneously recorded unit activity across all layers of the motor cortex while the animal was engaged in a movement direction task. Localization of the electrode array within the different layers of the cortex was determined by histology. We denoted units from layers 2 and 3 and units as upper layer units, and units from layers 5 and 6 as lower layer units. Analysis of unit spiking activity demonstrated that both the upper and lower layers encode movement and direction information. Unit responses in either cortical layer of the cortex were not preferentially associated with contralateral or ipsilateral movement. Aggregate analysis (633 neurons) and best session analysis (75 neurons) indicated that units in the lower layers (layers 5, 6) are more likely to encode direction information when compared to units in the upper layers (layers 2, 3) (p< 0.05). These results suggest that electrode sites clustered in the lower layers provide access to more salient control information for cortical neuroprostheses.

  19. Bipolar postpartum depression: An update and recommendations.

    Science.gov (United States)

    Sharma, Verinder; Doobay, Minakshi; Baczynski, Christine

    2017-09-01

    Over the past few years there has been a surge of interest in the study of bipolar postpartum depression (PPD); however, questions remain about its prevalence, screening, clinical features, and treatment. Three electronic databases, MEDLINE/PubMed (1966-2016), PsycINFO (1806-2016), and the Cochrane Database of Systematic Reviews, were searched using a combination of the keywords bipolar, depression, postpartum, peripartum, prevalence, screening, diagnosis, treatment, drugs, and psychotherapy. The reference lists of articles identified were also searched. All relevant articles published in English were included. Depending on the population studied, 21.4-54% of women with PPD have a diagnosis of bipolar disorder (BD). Characteristic clinical features include younger age at illness onset, first onset of depression after childbirth, onset immediately after delivery, atypical depressive symptoms, psychotic features, mixed features, and history of BD in first-degree family members. Treatment should be guided by symptom acuity, safety concerns, the patient's response to past treatments, drug tolerability, and breastfeeding preference. In the absence of controlled treatment data, preference should be given to drugs normally indicated for bipolar depression including lithium, quetiapine and lamotrigine. Although antidepressants have been studied in combination with mood stabilizers in bipolar depression, these drugs should be avoided due to likelihood of elevated risk of induction of manic symptoms in the postpartum period. In the postpartum period, bipolar PPD is common, can be differentiated from unipolar PPD, and needs to be identified promptly in order to expedite appropriate treatment. Future studies on pharmacotherapy and psychotherapy should focus on the acute and preventative treatment of bipolar PPD. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Anxiety, stress and perfectionism in bipolar disorder.

    Science.gov (United States)

    Corry, Justine; Green, Melissa; Roberts, Gloria; Frankland, Andrew; Wright, Adam; Lau, Phoebe; Loo, Colleen; Breakspear, Michael; Mitchell, Philip B

    2013-12-01

    Previous reports have highlighted perfectionism and related cognitive styles as a psychological risk factor for stress and anxiety symptoms as well as for the development of bipolar disorder symptoms. The anxiety disorders are highly comorbid with bipolar disorder but the mechanisms that underpin this comorbidity are yet to be determined. Measures of depressive, (hypo)manic, anxiety and stress symptoms and perfectionistic cognitive style were completed by a sample of 142 patients with bipolar disorder. Mediation models were used to explore the hypotheses that anxiety and stress symptoms would mediate relationships between perfectionistic cognitive styles, and bipolar disorder symptoms. Stress and anxiety both significantly mediated the relationship between both self-critical perfectionism and goal attainment values and bipolar depressive symptoms. Goal attainment values were not significantly related to hypomanic symptoms. Stress and anxiety symptoms did not significantly mediate the relationship between self-critical perfectionism and (hypo)manic symptoms. 1. These data are cross-sectional; hence the causality implied in the mediation models can only be inferred. 2. The clinic patients were less likely to present with (hypo)manic symptoms and therefore the reduced variability in the data may have contributed to the null findings for the mediation models with (hypo) manic symptoms. 3. Those patients who were experiencing current (hypo)manic symptoms may have answered the cognitive styles questionnaires differently than when euthymic. These findings highlight a plausible mechanism to understand the relationship between bipolar disorder and the anxiety disorders. Targeting self-critical perfectionism in the psychological treatment of bipolar disorder when there is anxiety comorbidity may result in more parsimonious treatments. © 2013 Published by Elsevier B.V.

  1. Big data for bipolar disorder.

    Science.gov (United States)

    Monteith, Scott; Glenn, Tasha; Geddes, John; Whybrow, Peter C; Bauer, Michael

    2016-12-01

    The delivery of psychiatric care is changing with a new emphasis on integrated care, preventative measures, population health, and the biological basis of disease. Fundamental to this transformation are big data and advances in the ability to analyze these data. The impact of big data on the routine treatment of bipolar disorder today and in the near future is discussed, with examples that relate to health policy, the discovery of new associations, and the study of rare events. The primary sources of big data today are electronic medical records (EMR), claims, and registry data from providers and payers. In the near future, data created by patients from active monitoring, passive monitoring of Internet and smartphone activities, and from sensors may be integrated with the EMR. Diverse data sources from outside of medicine, such as government financial data, will be linked for research. Over the long term, genetic and imaging data will be integrated with the EMR, and there will be more emphasis on predictive models. Many technical challenges remain when analyzing big data that relates to size, heterogeneity, complexity, and unstructured text data in the EMR. Human judgement and subject matter expertise are critical parts of big data analysis, and the active participation of psychiatrists is needed throughout the analytical process.

  2. Bipolar pulse generator for intense pulsed ion beam accelerator

    International Nuclear Information System (INIS)

    Ito, H.; Igawa, K.; Kitamura, I.; Masugata, K.

    2007-01-01

    A new type of pulsed ion beam accelerator named ''bipolar pulse accelerator'' (BPA) has been proposed in order to improve the purity of intense pulsed ion beams. To confirm the principle of the BPA, we developed a bipolar pulse generator for the bipolar pulse experiment, which consists of a Marx generator and a pulse forming line (PFL) with a rail gap switch on its end. In this article, we report the first experimental result of the bipolar pulse and evaluate the electrical characteristics of the bipolar pulse generator. When the bipolar pulse generator was operated at 70% of the full charge condition of the PFL, the bipolar pulse with the first (-138 kV, 72 ns) and the second pulse (+130 kV, 70 ns) was successfully obtained. The evaluation of the electrical characteristics indicates that the developed generator can produce the bipolar pulse with fast rise time and sharp reversing time

  3. Application of Bipolar Fuzzy Sets in Graph Structures

    Directory of Open Access Journals (Sweden)

    Muhammad Akram

    2016-01-01

    Full Text Available A graph structure is a useful tool in solving the combinatorial problems in different areas of computer science and computational intelligence systems. In this paper, we apply the concept of bipolar fuzzy sets to graph structures. We introduce certain notions, including bipolar fuzzy graph structure (BFGS, strong bipolar fuzzy graph structure, bipolar fuzzy Ni-cycle, bipolar fuzzy Ni-tree, bipolar fuzzy Ni-cut vertex, and bipolar fuzzy Ni-bridge, and illustrate these notions by several examples. We study ϕ-complement, self-complement, strong self-complement, and totally strong self-complement in bipolar fuzzy graph structures, and we investigate some of their interesting properties.

  4. Cardiovascular risk factors in outpatients with bipolar disorder

    NARCIS (Netherlands)

    Klumpers, U.M.H.; Boom, K.; Janssen, F.M.G.; Tulen, J.H.M.; Loonen, Anton J. M.

    2004-01-01

    Background: The mortality due to cardiovascular diseases in bipolar patients is much higher than in the general population. It is unclear whether lithium treatment contributes to this cardiovascular morbidity. Methods: The cardiovascular risk factors in outpatients with bipolar disorder on

  5. Cytokines in bipolar disorder vs. healthy control subjects

    DEFF Research Database (Denmark)

    Munkholm, Klaus; Braüner, Julie Vestergaard; Kessing, Lars Vedel

    2013-01-01

    Bipolar disorder may be associated with peripheral immune system dysfunction; however, results in individual studies are conflicting. Our aim was to systematically review evidence of peripheral cytokine alterations in bipolar disorder integrating findings from various affective states....

  6. Assessment of subjective and objective cognitive function in bipolar disorder

    DEFF Research Database (Denmark)

    Demant, Kirsa M; Vinberg, Maj; Kessing, Lars V

    2015-01-01

    Cognitive dysfunction is prevalent in bipolar disorder (BD). However, the evidence regarding the association between subjective cognitive complaints, objective cognitive performance and psychosocial function is sparse and inconsistent. Seventy seven patients with bipolar disorder who presented...

  7. Smartphone-based objective monitoring in bipolar disorder

    DEFF Research Database (Denmark)

    Faurholt-Jepsen, Maria; Bauer, Michael; Kessing, Lars Vedel

    2018-01-01

    , anxiety, substance abuse, eating disorder, schizophrenia and bipolar disorder have been developed and used. The present paper presents the status and findings from studies using automatically generated objective smartphone data in the monitoring of bipolar disorder, and addresses considerations...

  8. Immune activation by casein dietary antigens in bipolar disorder

    NARCIS (Netherlands)

    Severance, E.G.; Dupont, D.; Dickerson, F.B.; Stallings, C.R.; Origoni, A.E.; Krivogorsky, B.; Yang, S.; Haasnoot, W.; Yolken, R.H.

    2010-01-01

    Objectives: Inflammation and other immune processes are increasingly linked to psychiatric diseases. Antigenic triggers specific to bipolar disorder are not yet defined. We tested whether antibodies to bovine milk caseins were associated with bipolar disorder, and whether patients recognized

  9. Bipolar disorder: an update | Outhoff | South African Family Practice

    African Journals Online (AJOL)

    Bipolar disorder, characterised by alternating discrete episodes of (hypo)mania and depression, provides unique diagnostic and treatment challenges. Updated diagnostic (DSM-5) and current pharmacological treatment recommendations are briefly reviewed here. Keywords: bipolar disorder; diagnosis; evidence-based ...

  10. Nickel hydrogen bipolar battery electrode design

    Science.gov (United States)

    Puglisi, V. J.; Russell, P.; Verrier, D.; Hall, A.

    1985-01-01

    The preferred approach of the NASA development effort in nickel hydrogen battery design utilizes a bipolar plate stacking arrangement to obtain the required voltage-capacity configuration. In a bipolar stack, component designs must take into account not only the typical design considerations such as voltage, capacity and gas management, but also conductivity to the bipolar (i.e., intercell) plate. The nickel and hydrogen electrode development specifically relevant to bipolar cell operation is discussed. Nickel oxide electrodes, having variable type grids and in thicknesses up to .085 inch are being fabricated and characterized to provide a data base. A selection will be made based upon a system level tradeoff. Negative (hydrpogen) electrodes are being screened to select a high performance electrode which can function as a bipolar electrode. Present nickel hydrogen negative electrodes are not capable of conducting current through their cross-section. An electrode was tested which exhibits low charge and discharge polarization voltages and at the same time is conductive. Test data is presented.

  11. Comorbid medical illness in bipolar disorder.

    Science.gov (United States)

    Forty, Liz; Ulanova, Anna; Jones, Lisa; Jones, Ian; Gordon-Smith, Katherine; Fraser, Christine; Farmer, Anne; McGuffin, Peter; Lewis, Cathryn M; Hosang, Georgina M; Rivera, Margarita; Craddock, Nick

    2014-12-01

    Individuals with a mental health disorder appear to be at increased risk of medical illness. To examine rates of medical illnesses in patients with bipolar disorder (n = 1720) and to examine the clinical course of the bipolar illness according to lifetime medical illness burden. Participants recruited within the UK were asked about the lifetime occurrence of 20 medical illnesses, interviewed using the Schedules for Clinical Assessment in Neuropsychiatry (SCAN) and diagnosed according to DSM-IV criteria. We found significantly increased rates of several medical illnesses in our bipolar sample. A high medical illness burden was associated with a history of anxiety disorder, rapid cycling mood episodes, suicide attempts and mood episodes with a typically acute onset. Bipolar disorder is associated with high rates of medical illness. This comorbidity needs to be taken into account by services in order to improve outcomes for patients with bipolar disorder and also in research investigating the aetiology of affective disorder where shared biological pathways may play a role. Royal College of Psychiatrists.

  12. Bipolar magnetic semiconductor in silicene nanoribbons

    International Nuclear Information System (INIS)

    Farghadan, Rouhollah

    2017-01-01

    Highlights: • A new electronic phase for silicene nanoribbon in the presence of electric and magnetic fields. • Bipolar magnetic semiconductor with controllable spin-flip and spin-conserved gaps in silicene. • Robust bipolar magnetic semiconductor features in a rough silicene. • Perfect and reversible spin polarization in silicene nanoribbon junctions. - Abstract: A theoretical study was presented on generation of spin polarization in silicene nanoribbons using the single-band tight-binding approximation and the non-equilibrium Green’s function formalism. We focused on the effect of electric and exchange magnetic fields on the spin-filter capabilities of zigzag-edge silicene nanoribbons in the presence of the intrinsic spin-orbit interaction. The results show that a robust bipolar magnetic semiconductor with controllable spin-flip and spin-conserved gaps can be obtained when exchange magnetic and electric field strengths are both larger than the intrinsic spin-orbit interaction. Therefore, zigzag silicene nanoribbons could act as bipolar and perfect spin filter devices with a large spin-polarized current and a reversible spin polarization in the vicinity of the Fermi energy. We also investigated the effect of edge roughness and found that the bipolar magnetic semiconductor features are robust against edge disorder in silicene nanoribbon junctions. These results may be useful in multifunctional spin devices based on silicene nanoribbons.

  13. [Drug Abuse Comorbidity in Bipolar Disorder].

    Science.gov (United States)

    Ortiz, Óscar Medina

    2012-06-01

    Drug use among patients with bipolar disorder is greater than the one observed in the general population; psychotic episodes are likely to occur after consumption. This has implications in the prevention, etiology, management, and treatment of the disease. Bipolar disorder pathology is likely to have positive response to pharmacological treatment. Therefore, identifying the strategies with better results to be applied in these patients is fundamental for psychiatrists and primary care physicians. Review literature in order to determine the prevalence and characteristics of drug abuse in patients with bipolar disorder and establish the pharmacological strategies that have produced better results. Literature review. A great variety of studies demonstrate the relationship between bipolar disorder and drug use disorder. These patients are hospitalized more frequently, have an earlier onset of the disease, and present a larger number of depressive episodes and suicide attempts which affect the course of the disease. The drug with better results in the treatment of these patients is Divalproate. Satisfactory results have been also obtained with other mood stabilizers such as carbamazepine, lamotrigine, and the antipsychotic aripiprazole. Substance abuse is present in a large number of patients with bipolar disorder. The Divalproate is the drug that has shown better results in the studies. Copyright © 2012 Asociación Colombiana de Psiquiatría. Publicado por Elsevier España. All rights reserved.

  14. Family History in Patients with Bipolar Disorder.

    Science.gov (United States)

    Özdemir, Osman; Coşkun, Salih; Aktan Mutlu, Elif; Özdemir, Pınar Güzel; Atli, Abdullah; Yilmaz, Ekrem; Keskin, Sıddık

    2016-09-01

    In this study, we aimed to better understand the genetic transmission of bipolar disorder by examining the family history of patients. Sixty-three patients with bipolar disorder and their families were included. The final sample comprised 156 bipolar patients and their family members. An inclusion criterion was the presence of bipolar disorder history in the family. The diagnosis of other family members was confirmed by analyzing their files, hospital records, and by calling them to the hospital. Sixty-five patients were women (41.6%) and 91 were men (58.3%) (ratio of men/women: 1.40). When analyzing the results in terms of the transition of disease from the mother's or father's side, similar results were obtained: 25 patients were from the mother's side and 25 patients were from the father's side in 63 cases. The results of our study support the fact that a significant relationship exists between the degree of kinship and the heritability of bipolar disorder and, furthermore, that the effect of the maternal and paternal sides is similar on the transmission of genetic susceptibility.

  15. Bipolar magnetic semiconductor in silicene nanoribbons

    Energy Technology Data Exchange (ETDEWEB)

    Farghadan, Rouhollah, E-mail: rfarghadan@kashanu.ac.ir

    2017-08-01

    Highlights: • A new electronic phase for silicene nanoribbon in the presence of electric and magnetic fields. • Bipolar magnetic semiconductor with controllable spin-flip and spin-conserved gaps in silicene. • Robust bipolar magnetic semiconductor features in a rough silicene. • Perfect and reversible spin polarization in silicene nanoribbon junctions. - Abstract: A theoretical study was presented on generation of spin polarization in silicene nanoribbons using the single-band tight-binding approximation and the non-equilibrium Green’s function formalism. We focused on the effect of electric and exchange magnetic fields on the spin-filter capabilities of zigzag-edge silicene nanoribbons in the presence of the intrinsic spin-orbit interaction. The results show that a robust bipolar magnetic semiconductor with controllable spin-flip and spin-conserved gaps can be obtained when exchange magnetic and electric field strengths are both larger than the intrinsic spin-orbit interaction. Therefore, zigzag silicene nanoribbons could act as bipolar and perfect spin filter devices with a large spin-polarized current and a reversible spin polarization in the vicinity of the Fermi energy. We also investigated the effect of edge roughness and found that the bipolar magnetic semiconductor features are robust against edge disorder in silicene nanoribbon junctions. These results may be useful in multifunctional spin devices based on silicene nanoribbons.

  16. The Dutch Bipolar Offspring Study: 12-Year Follow-Up

    OpenAIRE

    Mesman, Esther; Nolen, Willem A.; Reichart, Catrien G.; Wals, Marjolein; Hillegers, Manon N. J.

    2013-01-01

    Objective: Offspring of bipolar parents have a genetically increased risk of developing mood disorders. In a longitudinal study, the authors followed a bipolar offspring cohort from adolescence into adulthood to determine the onset, prevalence, and early course of mood disorders and other psychopathology. Method: The Dutch bipolar offspring cohort is a fixed cohort initiated in 1997 (N=140; age range at baseline, 12-21 years). Bipolar offspring were psychiatrically evaluated at baseline and a...

  17. Rumination in bipolar disorder: evidence for an unquiet mind

    OpenAIRE

    Ghaznavi, Sharmin; Deckersbach, Thilo

    2012-01-01

    Abstract Depression in bipolar disorder has long been thought to be a state characterized by mental inactivity. However, recent research demonstrates that patients with bipolar disorder engage in rumination, a form of self-focused repetitive cognitive activity, in depressed as well as in manic states. While rumination has long been associated with depressed states in major depressive disorder, the finding that patients with bipolar disorder ruminate in manic states is unique to bipolar disord...

  18. A Novel Microdialysis Glucose Sensor System Based on Co-immobilizing on AU Micro-Electrode by SOL-GEL Technique

    National Research Council Canada - National Science Library

    Yu, Ping

    2001-01-01

    .... The sensor is based on co_immobilizing glucose oxidase (COD) with the catalase by sol-gel technique on the surface of the silicon bases with two pattern of An microelectrodes. A graduated ("sandwich...

  19. Risk factors for suicide among children and youths with bipolar spectrum and early bipolar disorder.

    Science.gov (United States)

    Rajewska-Rager, Aleksandra; Sibilski, Piotr; Lepczyńska, Natalia

    2015-01-01

    In recent years much attention has been given to determine risk factors for suicide among adults with bipolar disorder. Such studies concerning children and youths, which would also take into account the specificity of the developmental age, are still too few. The ability to identify risk factors for children and youths with mood disorders, as well as the possibility to monitor them, is an essential element in preventing suicidal behaviours. Previous studies have clearly indicated that in the group of patients with an early onset of the bipolar disorder the occurrence of suicidal thoughts and intentions were significantly increased. Identifying the risk of suicide is hindered further by the complexity of the phenomenon, which is a compound interaction of various factors: biological, environmental, sociological, psychological and clinical. This is especially true with young adults suffering from mental illness and presenting a number of other psychopathological symptoms. The following paper introduces and reviews the results of current studies, which analysed the risk factors for suicide among children and youths with bipolar spectrum or already diagnosed with bipolar disorder. For this purpose we conducted the overview of recent years literature available in PubMed/MEDLINE database, including the following search criteria: early onset bipolar disorder, bipolar disorder in children and young people, the spectrum of bipolar disorder, and suicidal ideation, suicidal intent, suicide.

  20. On Bipolar Valued Fuzzy k-Ideals in Hermirings

    International Nuclear Information System (INIS)

    Mahmood, T.; Ejaz, A.

    2015-01-01

    In this paper we discuss some results associated with bipolar valued fuzzy k -ideals of hermirings. We also define bipolar valued fuzzy k-intrinsic product and characterize k-hemiregular hermirings by using their bipolar valued fuzzy k -ideals. (author)

  1. Dose enhancement effects of X ray radiation in bipolar transistors

    International Nuclear Information System (INIS)

    Chen Panxun

    1997-01-01

    The author has presented behaviour degradation and dose enhancement effects of bipolar transistors in X ray irradiation environment. The relative dose enhancement factors of X ray radiation were measured in bipolar transistors by the experiment methods. The mechanism of bipolar device dose enhancement was investigated

  2. Family Functioning and the Course of Adolescent Bipolar Disorder

    Science.gov (United States)

    Sullivan, Aimee E.; Judd, Charles M.; Axelson, David A.; Miklowitz, David J.

    2012-01-01

    The symptoms of bipolar disorder affect and are affected by the functioning of family environments. Little is known, however, about the stability of family functioning among youth with bipolar disorder as they cycle in and out of mood episodes. This study examined family functioning and its relationship to symptoms of adolescent bipolar disorder,…

  3. Ion transport Modeling in a Bipolar Membrane

    International Nuclear Information System (INIS)

    Kim, Jung Soo; Park, Kwang Heon; Kim, Kwang Wook

    2010-01-01

    The COL(Carbonate-based Oxidative Leaching) process is an environmentally-friendly technique for collecting only uranium from spent fuel with oxidation leaching/ precipitation of carbonate solution. The bipolar membrane used for the electrolyte circulation of the salt used in the COL process is a special form of ion exchange membrane which combines CEM(cation exchange membrane) and AEM(anion exchange membrane). After arranging positive ion exchange layer toward negative terminal and positive ion exchange layer toward positive terminal, then supply electricity, water molecules are decomposed into protons and hydroxyl ions by a strong electric field in the transition region inside bipolar membrane.1) In this study, a theoretical approach to increase the efficiency of Na + and NO3 - ion collecting device using bipolar membrane was taken and simulating using the COMSOL program was tried. The details of results are also discussed

  4. Neuronal migration, apoptosis and bipolar disorder.

    Science.gov (United States)

    Uribe, Ezequiel; Wix, Richard

    2012-01-01

    Bipolar disorder, like the majority of psychiatric disorders, is considered a neurodevelopment disease of neurodevelopment. There is an increased rate of neuronal birth and death during this development period. In the particular case of the processes that determine neuronal death, it is known that those neurons that establish connections have to be removed from the central nervous system. There is a deficit of GABAergic interneurons in the cerebral cortex in bipolar disorder, accompanied by overexpression of proapoptic genes. There is also an alteration in the expression of molecules that mediate in the migration of these neurons and their inclusion in functional synapsis during the foetal stage. The role of these molecules in the neuronal death pathways by apoptosis will be reviewed here in an attempt to establish biological hypotheses of the genesis of bipolar disorder. Copyright © 2011 SEP y SEPB. Published by Elsevier Espana. All rights reserved.

  5. Concurrent hypokalemic periodic paralysis and bipolar disorder

    Directory of Open Access Journals (Sweden)

    Chia-Lin Lin

    2015-01-01

    Full Text Available Primary periodic paralysis is a rare autosomal dominant disorder of ion-channel dysfunction, manifested by episodic flaccid paresis secondary to abnormal sarcolemma excitability. Membrane destabilization involving Na, K-ATPase has been hypothesized to be a biological etiology of the bipolar disorder (BD and the mechanisms underlying lithium therapy have been linked to it. To date, there has been only one reported case of BD comorbid with periodic paralysis. Herein, we reported another case of concurrent bipolar mania and hypokalemic periodic paralysis (HPP, one special form of periodic paralysis. Consistent with the previous case, our patient responded well to lithium treatment for both bipolar mania and HPP. This might provide some support to the hypothesis that the therapeutic effects of lithium in both BD and HPP could be due to the correction of the underlying common pathophysiology.

  6. Fenomenologia do tempo vivido no transtorno bipolar

    Directory of Open Access Journals (Sweden)

    Virginia Moreira

    Full Text Available Com base na tradição da psicopatologia fenomenológica, este artigo se propõe a contribuir para a compreensão do mundo vivido do paciente bipolar, marcado por uma forte alteração do tempo vivido. Realizamos uma descrição deste tempo vivido significado de forma diferente nas oscilações de humor chamadas de fase maníaca e fase melancólica. Pensado a partir da temporalidade, na fase melancólica, o bipolar parece parar no tempo, não se lança em um devir. Na fase maníaca, o sujeito vive demasiadamente um agora como se tivesse explodido sua biografia. Concluímos que estas fases, ou dois pólos opostos no funcionamento temporal patológico do sofrimento bipolar, constituem fundamentalmente um mesmo mundo vivido.

  7. Genetic structure of personality factors and bipolar disorder in families segregating bipolar disorder.

    Science.gov (United States)

    Hare, Elizabeth; Contreras, Javier; Raventos, Henriette; Flores, Deborah; Jerez, Alvaro; Nicolini, Humberto; Ontiveros, Alfonso; Almasy, Laura; Escamilla, Michael

    2012-02-01

    Bipolar disorder (BPD) has been associated with variations in personality dimensions, but the nature of this relationship has been unclear. In this study, the heritabilities of BPD and the Big Five personality factors and the genetic correlations between BPD and personality factors are reported. The participants in this study were 1073 individuals from 172 families of Mexican or Central American ancestry. Heritabilities and genetic correlations were calculated under a polygenic model using the maximum-likelihood method of obtaining variance components implemented in the SOLAR software package. Heritabilities of 0.49, 0.43, and 0.43 were found for the narrowest phenotype (schizoaffective bipolar and bipolar I), the intermediate phenotype (schizoaffective bipolar, bipolar I, and bipolar II), and the broadest phenotype (schizoaffective bipolar, bipolar I, bipolar II, and recurrent depression), respectively. For the Big Five personality factors, heritabilities were 0.25 for agreeableness, 0.24 for conscientiousness, 0.24 for extraversion, 0.23 for neuroticism, and 0.32 for openness to experience. For the narrowest phenotype, a significant negative correlation (-0.32) with extraversion was found. For the broadest phenotype, negative correlations were found for agreeableness (-0.35), conscientiousness (-0.39), and extraversion (-0.44). A positive correlation (0.37) was found with neuroticism. It is not possible to determine whether aspects of personality are factors in the development of bipolar disorder or vice versa. The short form of the NEO does not provide the ability to examine in detail which facets of extraversion are most closely related to bipolar disorder or to compare our results with studies that have used the long version of the scale. This study establishes a partial genetic basis for the Big Five personality factors in this set of families, while the environmental variances demonstrate that non-genetic factors are also important in their influence on

  8. Nanosecond bipolar pulse generators for bioelectrics.

    Science.gov (United States)

    Xiao, Shu; Zhou, Chunrong; Yang, Enbo; Rajulapati, Sambasiva R

    2018-04-26

    Biological effects caused by a nanosecond pulse, such as cell membrane permeabilization, peripheral nerve excitation and cell blebbing, can be reduced or cancelled by applying another pulse of reversed polarity. Depending on the degree of cancellation, the pulse interval of these two pulses can be as long as dozens of microseconds. The cancellation effect diminishes as the pulse duration increases. To study the cancellation effect and potentially utilize it in electrotherapy, nanosecond bipolar pulse generators must be made available. An overview of the generators is given in this paper. A pulse forming line (PFL) that is matched at one end and shorted at the other end allows a bipolar pulse to be produced, but no delay can be inserted between the phases. Another generator employs a combination of a resistor, an inductor and a capacitor to form an RLC resonant circuit so that a bipolar pulse with a decaying magnitude can be generated. A third generator is a converter, which converts an existing unipolar pulse to a bipolar pulse. This is done by inserting an inductor in a transmission line. The first phase of the bipolar pulse is provided by the unipolar pulse's rising phase. The second phase is formed during the fall time of the unipolar pulse, when the inductor, which was previously charged during the flat part of the unipolar pulse, discharges its current to the load. The fourth type of generator uses multiple MOSFET switches stacked to turn on a pre-charged, bipolar RC network. This approach is the most flexible in that it can generate multiphasic pulses that have different amplitudes, delays, and durations. However, it may not be suitable for producing short nanosecond pulses (<100 ns), whereas the PFL approach and the RLC approach with gas switches are used for this range. Thus, each generator has its own advantages and applicable range. Copyright © 2018 Elsevier B.V. All rights reserved.

  9. Three times more days depressed than manic or hypomanic in both bipolar I and bipolar II disorder

    NARCIS (Netherlands)

    Kupka, Ralph W.; Altshuler, Lori L.; Nolen, Willem A.; Suppes, Trisha; Luckenbaugh, David A.; Leverich, Gabriele S.; Frye, Mark A.; Keck, Paul E.; McElroy, Susan L.; Grunze, Heinz; Post, Robert M.

    Objectives: To assess the proportion of time spent in mania, depression and euthymia in a large cohort of bipolar subjects studied longitudinally, and to investigate depression/mania ratios in patients with bipolar I versus bipolar II disorder. Methods: Clinician-adjusted self-ratings of mood were

  10. Alcoholism and anxiety in bipolar illness : Differential lifetime anxiety comorbidity in bipolar I women with and without alcoholism

    NARCIS (Netherlands)

    Levander, Eric; Frye, Mark A.; McElroy, Susan; Suppes, Trisha; Grunze, Heinz; Nolen, Willem A.; Kupka, Ralph; Keck, Paul E.; Leverich, Gabriele S.; Altshuler, Lori L.; Hwang, Sun; Mintz, Jim; Post, Robert M.

    Introduction: This study was undertaken to evaluate the prevalence rate of anxiety comorbidity in bipolar subjects with and without alcohol use disorders (AUD). Methods: Bipolar men and women who entered the Stanley Foundation Bipolar Network (SFBN) underwent a Structured Clinical Interview for

  11. Microelectrode voltammetry of multi-electron transfers complicated by coupled chemical equilibria: a general theory for the extended square scheme.

    Science.gov (United States)

    Laborda, Eduardo; Gómez-Gil, José María; Molina, Angela

    2017-06-28

    A very general and simple theoretical solution is presented for the current-potential-time response of reversible multi-electron transfer processes complicated by homogeneous chemical equilibria (the so-called extended square scheme). The expressions presented here are applicable regardless of the number of electrons transferred and coupled chemical processes, and they are particularized for a wide variety of microelectrode geometries. The voltammetric response of very different systems presenting multi-electron transfers is considered for the most widely-used techniques (namely, cyclic voltammetry, square wave voltammetry, differential pulse voltammetry and steady state voltammetry), studying the influence of the microelectrode geometry and the number and thermodynamics of the (electro)chemical steps. Most appropriate techniques and procedures for the determination of the 'interaction' between successive transfers are discussed. Special attention is paid to those situations where homogeneous chemical processes, such as protonation, complexation or ion association, affect the electrochemical behaviour of the system by different stabilization of the oxidation states.

  12. In vivo pH monitoring using boron doped diamond microelectrode and silver needles: Application to stomach disorder diagnosis

    OpenAIRE

    Fierro, St?phane; Seishima, Ryo; Nagano, Osamu; Saya, Hideyuki; Einaga, Yasuaki

    2013-01-01

    This study presents the in vivo electrochemical monitoring of pH using boron doped diamond (BDD) microelectrode and silver needles for potential application in medical diagnosis. Accurate calibration curve for pH determination were obtained through in vitro electrochemical measurements. The increase induced in stomach pH by treatment with pantoprazole was used to demonstrate that it is possible to monitor the pH in vivo using the simple and noninvasive system proposed herein. Using the result...

  13. Effect of island shape on dielectrophoretic assembly of metal nanoparticle chains in a conductive-island-based microelectrode system

    International Nuclear Information System (INIS)

    Ding, Haitao; Shao, Jinyou; Ding, Yucheng; Liu, Weiyu; Li, Xiangming; Tian, Hongmiao; Zhou, Yaopei

    2015-01-01

    Highlights: • Conductive island shape influences the dynamic process occurring in DEP assembly of 10 nm gold nanoparticles in a conductive-island-based microelectrode system. • The DEP-assembled nanoparticle wires form a straighter conduction path with the increase in the geometric angle of conductive island tip. • The different island shapes distort the DEP force distribution and increase the local electrothermally induced fluid flow to different extents, which is important for the morphology and electrical conductance quality of the DEP-assembled metal nanoparticle chains. - Abstract: The electrical conduction quality of an electric circuit connection formed by dielectrophoretic (DEP)-assembled metal nanoparticle wires between small conductive elements plays a significant role in electronic devices. One of the major challenges for improving the electrical conductance of nanowires is optimizing their geometric morphology. So far, the electrical conduction quality has been enhanced by optimizing the AC frequency and conductivity of nanoparticle suspensions. Herein, the effect of the conductive island shapes on the dynamic process occurring in a DEP assembly of 10 nm gold nanoparticles was investigated in a conductive-island-based microelectrode system. The nanoparticle wires between the microelectrodes were assembled in situ from colloidal suspensions. The wires were grown in a much straighter route by increasing the geometric angle of the conductive-island tip. To validate the experiments, the effects of mutual DEP interactions and electrothermally induced fluid flow on the dynamic behavior of particle motion for different island geometric configurations in the conductive-island-based microelectrode system were determined by numerical simulations. The simulation results are consistent with those of experiments. This indicates that different conductive island shapes change the distribution of DEP force and increase the electrothermally induced fluid flow to

  14. Magnetron sputtered diamond-like carbon microelectrodes for on-chip measurement of quantal catecholamine release from cells

    OpenAIRE

    Gao, Yuanfang; Chen, Xiaohui; Gupta, Sanju; Gillis, Kevin D.; Gangopadhyay, Shubhra

    2008-01-01

    Carbon electrodes are widely used in electrochemistry due to their low cost, wide potential window, and low and stable background noise. Carbon-fiber electrodes (CFE) are commonly used to electrochemically measure “quantal” catecholamine release via exocytosis from individual cells, but it is difficult to integrate CFEs into lab-on-a-chip devices. Here we report the development of nitrogen doped diamond-like carbon (DLC:N) microelectrodes on a chip to monitor quantal release of catecholamines...

  15. O2 Plasma Etching and Antistatic Gun Surface Modifications for CNT Yarn Microelectrode Improve Sensitivity and Antifouling Properties.

    Science.gov (United States)

    Yang, Cheng; Wang, Ying; Jacobs, Christopher B; Ivanov, Ilia N; Venton, B Jill

    2017-05-16

    Carbon nanotube (CNT) based microelectrodes exhibit rapid and selective detection of neurotransmitters. While different fabrication strategies and geometries of CNT microelectrodes have been characterized, relatively little research has investigated ways to selectively enhance their electrochemical properties. In this work, we introduce two simple, reproducible, low-cost, and efficient surface modification methods for carbon nanotube yarn microelectrodes (CNTYMEs): O 2 plasma etching and antistatic gun treatment. O 2 plasma etching was performed by a microwave plasma system with oxygen gas flow and the optimized time for treatment was 1 min. The antistatic gun treatment flows ions by the electrode surface; two triggers of the antistatic gun was the optimized number on the CNTYME surface. Current for dopamine at CNTYMEs increased 3-fold after O 2 plasma etching and 4-fold after antistatic gun treatment. When the two treatments were combined, the current increased 12-fold, showing the two effects are due to independent mechanisms that tune the surface properties. O 2 plasma etching increased the sensitivity due to increased surface oxygen content but did not affect surface roughness while the antistatic gun treatment increased surface roughness but not oxygen content. The effect of tissue fouling on CNT yarns was studied for the first time, and the relatively hydrophilic surface after O 2 plasma etching provided better resistance to fouling than unmodified or antistatic gun treated CNTYMEs. Overall, O 2 plasma etching and antistatic gun treatment improve the sensitivity of CNTYMEs by different mechanisms, providing the possibility to tune the CNTYME surface and enhance sensitivity.

  16. Spatial and temporal characteristics of V1 microstimulation during chronic implantation of a microelectrode array in a behaving macaque

    Science.gov (United States)

    Davis, T. S.; Parker, R. A.; House, P. A.; Bagley, E.; Wendelken, S.; Normann, R. A.; Greger, B.

    2012-12-01

    Objective. It has been hypothesized that a vision prosthesis capable of evoking useful visual percepts can be based upon electrically stimulating the primary visual cortex (V1) of a blind human subject via penetrating microelectrode arrays. As a continuation of earlier work, we examined several spatial and temporal characteristics of V1 microstimulation. Approach. An array of 100 penetrating microelectrodes was chronically implanted in V1 of a behaving macaque monkey. Microstimulation thresholds were measured using a two-alternative forced choice detection task. Relative locations of electrically-evoked percepts were measured using a memory saccade-to-target task. Main results. The principal finding was that two years after implantation we were able to evoke behavioural responses to electric stimulation across the spatial extent of the array using groups of contiguous electrodes. Consistent responses to stimulation were evoked at an average threshold current per electrode of 204 ± 49 µA (mean ± std) for groups of four electrodes and 91 ± 25 µA for groups of nine electrodes. Saccades to electrically-evoked percepts using groups of nine electrodes showed that the animal could discriminate spatially distinct percepts with groups having an average separation of 1.6 ± 0.3 mm (mean ± std) in cortex and 1.0° ± 0.2° in visual space. Significance. These results demonstrate chronic perceptual functionality and provide evidence for the feasibility of a cortically-based vision prosthesis for the blind using penetrating microelectrodes.

  17. Influence of droplet coverage on the electrochemical response of planar microelectrodes and potential solving strategies based on nesting concept

    Directory of Open Access Journals (Sweden)

    Yue Yu

    2016-08-01

    Full Text Available Recently, biosensors have been widely used for the detection of bacteria, viruses and other toxins. Electrodes, as commonly used transducers, are a vital part of electrochemical biosensors. The coverage of the droplets can change significantly based on the hydrophobicity of the microelectrode surface materials. In the present research, screen-printed interdigitated microelectrodes (SPIMs, as one type of planar microelectrode, were applied to investigate the influence of droplet coverage on electrochemical response. Furthermore, three dimensional (3D printing technology was employed to print smart devices with different diameters based on the nesting concept. Theoretical explanations were proposed to elucidate the influence of the droplet coverage on the electrochemical response. 3D-printed ring devices were used to incubate the SPIMs and the analytical performances of the SPIMs were tested. According to the results obtained, our device successfully improved the stability of the signal responses and eliminated irregular signal changes to a large extent. Our proposed method based on the nesting concept provides a promising method for the fabrication of stable electrochemical biosensors. We also introduced two types of electrode bases to improve the signal stability.

  18. Nanostructured gold microelectrodes for SERS and EIS measurements by incorporating ZnO nanorod growth with electroplating

    Science.gov (United States)

    Zong, Xianli; Zhu, Rong; Guo, Xiaoliang

    2015-01-01

    In this paper, a fine gold nanostructure synthesized on selective planar microelectrodes in micro-chip is realized by using an advanced hybrid fabrication approach incorporating growth of nanorods (NRs) with gold electroplating. By this developed nanostructure, integration of in-situ surface-enhanced Raman spectroscopy (SERS) detection with electrochemical impedance spectroscopy (EIS) measurement for label-free, nondestructive, real-time and rapid monitoring on a single cell has been achieved. Moreover, parameters of Au nanostructures such as size of nanoholes/nanogaps can be controllably adjusted in the fabrication. We have demonstrated a SERS enhancement factor of up to ~2.24 × 106 and double-layer impedance decrease ratio of 90% ~ 95% at low frequency range below 200 kHz by using nanostructured microelectrodes. SERS detection and in-situ EIS measurement of a trapped single cell by using planar microelectrodes are realized to demonstrate the compatibility, multi-functions, high-sensitivity and simplicity of the micro-chip system. This dual function platform integrating SERS and EIS is of great significance in biological, biochemical and biomedical applications. PMID:26558325

  19. The Polypyrrole/Multiwalled Carbon Nanotube Modified Au Microelectrode for Sensitive Electrochemical Detection of Trace Levels of Pb2+

    Directory of Open Access Journals (Sweden)

    Xuxing Zhu

    2017-03-01

    Full Text Available The sensitive detection of trace levels of heavy metal ions such as Pb2+ is of significant importance due to the health hazard they pose. In this paper, we present a polypyrrole (PPy/multiwalled carbon nanotube (MWCNT-modified Au microelectrode. The PPy/MWCNT composite film was electrochemically deposited on the microelectrode by cyclic voltammetry (CV. The composite film was investigated by scanning electron microscope (SEM, CV, and electrochemical impedance spectroscopy (EIS, and the results show that this film presents a uniformly distributed and web-like entangled structure and good conductivity. Differential pulse stripping voltammetry (DPSV was applied to determine trace levels of Pb2+. Experimental conditions including accumulation time and deposition potential were optimized. In optimal conditions, the PPy/MWCNT-modified microelectrode performed sensitive detection of Pb2+ within a concentration range from 1 to 100 μg·L−1, and the limit of detection was 0.65 μg·L−1 at the signal-to-noise ratio of three.

  20. Prediction of transition from common adolescent bipolar experiences to bipolar disorder: 10-year study.

    Science.gov (United States)

    Tijssen, Marijn J A; van Os, Jim; Wittchen, Hans-Ulrich; Lieb, Roselind; Beesdo, Katja; Mengelers, Ron; Wichers, Marieke

    2010-02-01

    Although (hypo)manic symptoms are common in adolescence, transition to adult bipolar disorder is infrequent. To examine whether the risk of transition to bipolar disorder is conditional on the extent of persistence of subthreshold affective phenotypes. In a 10-year prospective community cohort study of 3021 adolescents and young adults, the association between persistence of affective symptoms over 3 years and the 10-year clinical outcomes of incident DSM-IV (hypo)manic episodes and incident use of mental healthcare was assessed. Transition to clinical outcome was associated with persistence of symptoms in a dose-dependent manner. Around 30-40% of clinical outcomes could be traced to prior persistence of affective symptoms. In a substantial proportion of individuals, onset of clinical bipolar disorder may be seen as the poor outcome of a developmentally common and usually transitory non-clinical bipolar phenotype.

  1. Signal processing methods for reducing artifacts in microelectrode brain recordings caused by functional electrical stimulation

    Science.gov (United States)

    Young, D.; Willett, F.; Memberg, W. D.; Murphy, B.; Walter, B.; Sweet, J.; Miller, J.; Hochberg, L. R.; Kirsch, R. F.; Ajiboye, A. B.

    2018-04-01

    Objective. Functional electrical stimulation (FES) is a promising technology for restoring movement to paralyzed limbs. Intracortical brain-computer interfaces (iBCIs) have enabled intuitive control over virtual and robotic movements, and more recently over upper extremity FES neuroprostheses. However, electrical stimulation of muscles creates artifacts in intracortical microelectrode recordings that could degrade iBCI performance. Here, we investigate methods for reducing the cortically recorded artifacts that result from peripheral electrical stimulation. Approach. One participant in the BrainGate2 pilot clinical trial had two intracortical microelectrode arrays placed in the motor cortex, and thirty-six stimulating intramuscular electrodes placed in the muscles of the contralateral limb. We characterized intracortically recorded electrical artifacts during both intramuscular and surface stimulation. We compared the performance of three artifact reduction methods: blanking, common average reference (CAR) and linear regression reference (LRR), which creates channel-specific reference signals, composed of weighted sums of other channels. Main results. Electrical artifacts resulting from surface stimulation were 175  ×  larger than baseline neural recordings (which were 110 µV peak-to-peak), while intramuscular stimulation artifacts were only 4  ×  larger. The artifact waveforms were highly consistent across electrodes within each array. Application of LRR reduced artifact magnitudes to less than 10 µV and largely preserved the original neural feature values used for decoding. Unmitigated stimulation artifacts decreased iBCI decoding performance, but performance was almost completely recovered using LRR, which outperformed CAR and blanking and extracted useful neural information during stimulation artifact periods. Significance. The LRR method was effective at reducing electrical artifacts resulting from both intramuscular and surface FES, and

  2. Microfabrication of an Implantable silicone Microelectrode array for an epiretinal prosthesis

    Energy Technology Data Exchange (ETDEWEB)

    Maghribi, Mariam Nader [Univ. of California, Davis, CA (United States)

    2003-06-10

    Millions of people suffering from diseases such as retinitis pigmentosa and macular degeneration are legally blind due to the loss of photoreceptor function. Fortunately a large percentage of the neural cells connected to the photoreceptors remain viable, and electrical stimulation of these cells has been shown to result in visual perception. These findings have generated worldwide efforts to develop a retinal prosthesis device, with the hope of restoring vision. Advances in microfabrication, integrated circuits, and wireless technologies provide the means to reach this challenging goal. This dissertation describes the development of innovative silicone-based microfabrication techniques for producing an implantable microelectrode array. The microelectrode array is a component of an epiretinal prosthesis being developed by a multi-laboratory consortium. This array will serve as the interface between an electronic imaging system and the human eye, directly stimulating retinal neurons via thin film conducting traces. Because the array is intended as a long-term implant, vital biological and physical design requirements must be met. A retinal implant poses difficult engineering challenges due to the size of the intraocular cavity and the delicate retina. Not only does it have to be biocompatible in terms of cytotoxicity and degradation, but it also has to be structurally biocompatible, with regard to smooth edges and high conformability; basically mimicking the biological tissue. This is vital to minimize stress and prevent physical damage to the retina. Also, the device must be robust to withstand the forces imposed on it during fabrication and implantation. In order to meet these biocompatibility needs, the use of non-conventional microfabrication materials such as silicone is required. This mandates the enhancement of currently available polymer-based fabrication techniques and the development of new microfabrication methods. Through an iterative process, devices

  3. Magnesium microelectrode corrosion product transport modelling in relation to chloride induced pitting

    International Nuclear Information System (INIS)

    Burrows, R.; Cook, A.; Stevens, N.P.C.

    2012-09-01

    The high magnesium alloy Magnox is used as a fuel clad for the UK gas cooled, graphite moderated reactors of the same name. The fuel is metallic uranium (typically natural enrichment), so a low neutron absorption cross-section clad is required. Following discharge from reactor, spent fuel is stored in water, which acts as an effective heat transfer medium and biological shield. The chemistry of these ponds is carefully controlled to ensure that the Magnox clad remains in a passive state. This is primarily through the maintenance of a high pH and very low anion concentration. Of particular concern is the presence of chloride ions as even very low levels may allow localised corrosion to initiate. Although extensive work has been undertaken historically considering the behaviour of Magnox clad and the acceptable storage envelopes, the challenges of ageing plant and aspirations for accelerated decommissioning give value to further understanding of the corrosion mechanisms of this material. Recently, electrochemical techniques have been employed to characterise performance in a variety of chemistries and microelectrodes have been produced which have shown characteristics of salt film corrosion at moderate chloride concentrations under polarisation. A characteristic of the electrochemical response observed during the mass transport limited (potential independent) salt film regime has been periodic transients which correspond to emission of microscopic hydrogen bubbles from the microelectrode cavity. A simple finite element multi-physics model has been employed to assist in understanding the dominant processes of corrosion product transport away from a magnesium electrode surface which is dissolving under a salt film and this shows that characteristic transients observed in electrochemical tests may be simulated with reasonable agreement by consideration of convection from laminar flow around hydrogen micro-bubbles in the pit cavity combined with aqueous diffusion in the

  4. BIPOLAR DISORDER AND METABOLIC SYNDROME: COMORBIDITY OR SIDE EFFECTS OF TREATMENT OF BIPOLAR DISORDER

    OpenAIRE

    Babić, Dragan; Maslov, Boris; Nikolić, Katica; Martinac, Marko; Uzun, Suzana; Kozumplik, Oliver

    2010-01-01

    Objective: There is evidence that people with mental disorders are more likely to suffer from metabolic syndrome. In the last decades there has been an increase in interest for researching metabolic syndrome in psychiatric patients and plenty of evidence about their association. However, investigations on the prevalence of metabolic syndrome in patients with bipolar disorder are still surprisingly rare. The aim of this paper is to analyze comorbidity of bipolar disorder and metabolic syndrome...

  5. Bipolar Disorder in Children and Teens

    Science.gov (United States)

    ... separation anxiety. Sometimes behavior problems go along with mood episodes. Young people may take a lot of risks, such as driving too fast or spending too much money. Some young people with bipolar disorder think about suicide. Watch for any signs of suicidal thinking. Take ...

  6. Social dysfunction in bipolar disorder: pilot study.

    Science.gov (United States)

    de Almeida Rocca, Cristiana Castanho; de Macedo-Soares, Marcia Britto; Gorenstein, Clarice; Tamada, Renata Sayuri; Issler, Cilly Kluger; Dias, Rodrigo Silva; Schwartzmann, Angela Maria; Lafer, Beny

    2008-08-01

    The purpose of the present study was to assess the social skills of euthymic patients with bipolar disorder. A group of 25 outpatients with bipolar disorder type I were evaluated in comparison with a group of 31 healthy volunteers who were matched in terms of level of education, age, sex and intelligence. Both groups were assessed using a self-report questionnaire, the Brazilian Inventario de Habilidades Sociais (IHS, Social Skills Inventory). Two Wechsler Adult Intelligence Scale subtests (Picture Arrangement and Comprehension) were also used in order to assess subject ability to analyse social situations and to make judgements, respectively. Patients with bipolar disorder had lower IHS scores for the domains that assessed conversational skills/social self-confidence and social openness to new people/situations. Patients with anxiety disorders had high scores for the domain that assessed self-confidence in the expression of positive emotions. No differences were found between patients and controls in performance on the Wechsler Adult Intelligence Scale Picture Arrangement and Comprehension subtests. Euthymic patients with bipolar disorder present inhibited and overattentive behaviour in relation to other people and their environment. This behaviour might have a negative impact on their level of social functioning and quality of life.

  7. Cognitive Impairment in Euthymic Pediatric Bipolar Disorder

    DEFF Research Database (Denmark)

    Elias, Liana R.; Miskowiak, Kamilla W.; Vale, Antônio M. O.

    2017-01-01

    OBJECTIVE: To perform a systematic review and meta-analysis of studies investigating neurocognition in euthymic youths with bipolar disorder (BD) compared to healthy controls (HCs). METHOD: A systematic literature search was conducted in the PubMed/MEDLINE, PsycINFO, and EMBASE databases from inc...

  8. Bipolar Disorder in Adolescence: Diagnosis and Treatment.

    Science.gov (United States)

    Wilkinson, Great Buyck; Taylor, Priscilla; Holt, Jan R.

    2002-01-01

    Due to developmental issues and overlapping symptoms with other disorders, diagnosing bipolar disorder in adolescents is often a confusing and complex process. This article highlights diagnostic criteria, symptoms and behaviors, and the differential diagnosis process. Treatment options are also discussed. (Contains 17 references.) (GCP)

  9. Comorbidity of bipolar disorder and eating disorders.

    Science.gov (United States)

    Álvarez Ruiz, Eva M; Gutiérrez-Rojas, Luis

    2015-01-01

    The comorbidity of bipolar disorder and eating disorders has not been studied in depth. In addition, clinical implications involved in the appearance of both disorders are very important. A systematic literature review of MEDLINE published up to September 2013 was performed, analyzing all the articles that studied the comorbidity of both conditions (bipolar disorder and eating disorders) and others research that studied the efficacy of pharmacological treatment and psychotherapy to improve these illnesses. In this review we found a high comorbidity of bipolar disorder and eating disorders, especially of bulimia nervosa and binge eating disorder. Studies show that lithium and topiramate are 2 of the more effective pharmacological agents in the treatment of both disorders. There are a lot of studies that show evidence of comorbidity of bipolar disorder and eating disorders. However, further research is needed on assessment and treatment when these conditions co-exist, as well as study into the biopsychological aspects to determine the comorbid aetiology. Copyright © 2014 SEP y SEPB. Published by Elsevier España. All rights reserved.

  10. Bipolar disorder: Evidence for a major locus

    Energy Technology Data Exchange (ETDEWEB)

    Spence, M.A.; Flodman, P.L. [Univ. of California, Irvine, CA (United States); Sadovnick, A.D.; Ameli, H. [Univ. of British Columbia, Vancouver (Canada)] [and others

    1995-10-09

    Complex segregation analyses were conducted on families of bipolar I and bipolar II probands to delineate the mode of inheritance. The probands were ascertained from consecutive referrals to the Mood Disorder Service, University Hospital, University of British Columbia and diagnosed by DSM-III-R and Research Diagnostic Criteria. Data were available on over 1,500 first-degree relatives of the 186 Caucasian probands. The purpose of the analyses was to determine if, after correcting for age and birth cohort, there was evidence for a single major locus. Five models were fit to the data using the statistical package SAGE: (1) dominant, (2) recessive, (3) arbitrary mendelian inheritance, (4) environmental, and (5) no major effects. A single dominant, mendelian major locus was the best fitting of these models for the sample of bipolar I and II probands when only bipolar relatives were defined as affected (polygenic inheritance could not be tested). Adding recurrent major depression to the diagnosis {open_quotes}affected{close_quotes} for relatives reduced the evidence for a major locus effect. Our findings support the undertaking of linkage studies and are consistent with the analyses of the National Institutes of Mental Health (NIMH) Collaborative Study data by Rice et al. and Blangero and Elston. 39 refs., 4 tabs.

  11. A new bipolar nebula in Centaurus

    International Nuclear Information System (INIS)

    Wegner, G.; Glass, I.S.

    1979-01-01

    A new bipolar or butterfly-shaped nebula has been discovered and shown to have an infrared excess. The spectra of the central object and wings are of similar type, around G0. No emission lines are apparent. The infrared excess appears to be due to thermal emission from dust. (U.K.)

  12. Aggression and substance abuse in bipolar disorder.

    Science.gov (United States)

    Grunebaum, Michael F; Galfalvy, Hanga C; Nichols, C Matthew; Caldeira, Nathilee A; Sher, Leo; Dervic, Kanita; Burke, Ainsley K; Mann, J John; Oquendo, Maria A

    2006-10-01

    The goal of this retrospective study was to examine factors differentiating persons with bipolar disorder who did or did not have comorbid lifetime substance use disorders (SUD) at an index assessment. We also explored the chronology of onset of mood and SUD. We studied 146 subjects with DSM-defined bipolar disorder. Subgroups with and without lifetime SUD were compared on demographic and clinical measures. Substance abuse disorders in this bipolar sample were associated with male sex, impulsive-aggressive traits, comorbid conduct and Cluster B personality disorders, number of suicide attempts and earlier age at onset of a first mood episode. In a multivariable logistic regression analysis, male sex and aggression and possibly earlier age at mood disorder onset were associated with SUD. In those with or without SUD, the first mood episode tended to be depressive and to precede the onset of SUD. In persons with bipolar disorder, an earlier age of onset and aggressive traits appear to be factors associated with later development of comorbid SUD.

  13. Oxide bipolar electronics: materials, devices and circuits

    International Nuclear Information System (INIS)

    Grundmann, Marius; Klüpfel, Fabian; Karsthof, Robert; Schlupp, Peter; Schein, Friedrich-Leonhard; Splith, Daniel; Yang, Chang; Bitter, Sofie; Von Wenckstern, Holger

    2016-01-01

    We present the history of, and the latest progress in, the field of bipolar oxide thin film devices. As such we consider primarily pn-junctions in which at least one of the materials is a metal oxide semiconductor. A wide range of n-type and p-type oxides has been explored for the formation of such bipolar diodes. Since most oxide semiconductors are unipolar, challenges and opportunities exist with regard to the formation of heterojunction diodes and band lineups. Recently, various approaches have led to devices with high rectification, namely p-type ZnCo 2 O 4 and NiO on n-type ZnO and amorphous zinc-tin-oxide. Subsequent bipolar devices and applications such as photodetectors, solar cells, junction field-effect transistors and integrated circuits like inverters and ring oscillators are discussed. The tremendous progress shows that bipolar oxide electronics has evolved from the exploration of various materials and heterostructures to the demonstration of functioning integrated circuits. Therefore a viable, facile and high performance technology is ready for further exploitation and performance optimization. (topical review)

  14. Bipolarity and Ambivalence in Landscape Architecture

    NARCIS (Netherlands)

    Koh, J.

    2010-01-01

    Our discipline of landscape architecture contains bipolarity, not only in terms of landscape and architecture but also because the idea of landscape is both aesthetic and scientific. Furthermore, within landscape architecture there is a gap between design (as implied by architecture) and planning

  15. Heart rate variability in bipolar disorder

    DEFF Research Database (Denmark)

    Faurholt-Jepsen, Maria; Kessing, Lars Vedel; Munkholm, Klaus

    2017-01-01

    Background Heart rate variability (HRV) has been suggested reduced in bipolar disorder (BD) compared with healthy individuals (HC). This meta-analysis investigated: HRV differences in BD compared with HC, major depressive disorder or schizophrenia; HRV differences between affective states; HRV...

  16. Clinical practice recommendations for bipolar disorder.

    Science.gov (United States)

    Malhi, G S; Adams, D; Lampe, L; Paton, M; O'Connor, N; Newton, L A; Walter, G; Taylor, A; Porter, R; Mulder, R T; Berk, M

    2009-01-01

    To provide clinically relevant evidence-based recommendations for the management of bipolar disorder in adults that are informative, easy to assimilate and facilitate clinical decision-making. A comprehensive literature review of over 500 articles was undertaken using electronic database search engines (e.g. MEDLINE, PsychINFO and Cochrane reviews). In addition articles, book chapters and other literature known to the authors were reviewed. The findings were then formulated into a set of recommendations that were developed by a multidisciplinary team of clinicians who routinely deal with mood disorders. These preliminary recommendations underwent extensive consultative review by a broader advisory panel that included experts in the field, clinical staff and patient representatives. The clinical practice recommendations for bipolar disorder (bipolar CPR) summarise evidence-based treatments and provide a synopsis of recommendations relating to each phase of the illness. They are designed for clinical use and have therefore been presented succinctly in an innovative and engaging manner that is clear and informative. These up-to-date recommendations provide an evidence-based framework that incorporates clinical wisdom and consideration of individual factors in the management of bipolar disorder. Further, the novel style and practical approach should promote their uptake and implementation.

  17. Bias in emerging biomarkers for bipolar disorder

    DEFF Research Database (Denmark)

    Carvalho, A F; Köhler, C A; Fernandes, B S

    2016-01-01

    BACKGROUND: To date no comprehensive evaluation has appraised the likelihood of bias or the strength of the evidence of peripheral biomarkers for bipolar disorder (BD). Here we performed an umbrella review of meta-analyses of peripheral non-genetic biomarkers for BD. METHOD: The Pubmed/Medline, E...

  18. Novel antipsychotics in bipolar and schizoaffective mania

    NARCIS (Netherlands)

    Slooff, CJ

    Objective: Novel antipsychotics are increasingly used in the treatment of bipolar and schizoaffective mania. This paper presents an overview of the controlled studies in this field. Method: Using cross-references, a computerized search was performed on MEDLINE and EMBASE psychiatry covering the

  19. Microelectrode array-induced neuronal alignment directs neurite outgrowth: analysis using a fast Fourier transform (FFT).

    Science.gov (United States)

    Radotić, Viktorija; Braeken, Dries; Kovačić, Damir

    2017-12-01

    Many studies have shown that the topography of the substrate on which neurons are cultured can promote neuronal adhesion and guide neurite outgrowth in the same direction as the underlying topography. To investigate this effect, isotropic substrate-complementary metal-oxide-semiconductor (CMOS) chips were used as one example of microelectrode arrays (MEAs) for directing neurite growth of spiral ganglion neurons. Neurons were isolated from 5 to 7-day-old rat pups, cultured 1 day in vitro (DIV) and 4 DIV, and then fixed with 4% paraformaldehyde. For analysis of neurite alignment and orientation, fast Fourier transformation (FFT) was used. Results revealed that on the micro-patterned surface of a CMOS chip, neurons orient their neurites along three directional axes at 30, 90, and 150° and that neurites aligned in straight lines between adjacent pillars and mostly followed a single direction while occasionally branching perpendicularly. We conclude that the CMOS substrate guides neurites towards electrodes by means of their structured pillar organization and can produce electrical stimulation of aligned neurons as well as monitoring their neural activities once neurites are in the vicinity of electrodes. These findings are of particular interest for neural tissue engineering with the ultimate goal of developing a new generation of MEA essential for improved electrical stimulation of auditory neurons.

  20. Interdigitated microelectrode based impedance biosensor for detection of salmonella enteritidis in food samples

    International Nuclear Information System (INIS)

    Kim, G; Morgan, M; Hahm, B K; Bhunia, A; Mun, J H; Om, A S

    2008-01-01

    Salmonella enteritidis outbreaks continue to occur, and S. enteritidis-related outbreaks from various food sources have increased public awareness of this pathogen. Conventional methods for pathogens detection and identification are labor-intensive and take days to complete. Some immunological rapid assays are developed, but these assays still require prolonged enrichment steps. Recently developed biosensors have shown great potential for the rapid detection of foodborne pathogens. To develop the biosensor, an interdigitated microelectrode (IME) was fabricated by using semiconductor fabrication process. Anti-Salmonella antibodies were immobilized based on avidin-biotin binding on the surface of the IME to form an active sensing layer. To increase the sensitivity of the sensor, three types of sensors that have different electrode gap sizes (2 μm, 5 μm, 10 μm) were fabricated and tested. The impedimetric biosensor could detect 10 3 CFU/mL of Salmonella in pork meat extract with an incubation time of 5 minutes. This method may provide a simple, rapid and sensitive method to detect foodborne pathogens

  1. Application of active electrode compensation to perform continuous voltage-clamp recordings with sharp microelectrodes.

    Science.gov (United States)

    Gómez-González, J F; Destexhe, A; Bal, T

    2014-10-01

    Electrophysiological recordings of single neurons in brain tissues are very common in neuroscience. Glass microelectrodes filled with an electrolyte are used to impale the cell membrane in order to record the membrane potential or to inject current. Their high resistance induces a high voltage drop when passing current and it is essential to correct the voltage measurements. In particular, for voltage clamping, the traditional alternatives are two-electrode voltage-clamp technique or discontinuous single electrode voltage-clamp (dSEVC). Nevertheless, it is generally difficult to impale two electrodes in a same neuron and the switching frequency is limited to low frequencies in the case of dSEVC. We present a novel fully computer-implemented alternative to perform continuous voltage-clamp recordings with a single sharp-electrode. To reach such voltage-clamp recordings, we combine an active electrode compensation algorithm (AEC) with a digital controller (AECVC). We applied two types of control-systems: a linear controller (proportional plus integrative controller) and a model-based controller (optimal control). We compared the performance of the two methods to dSEVC using a dynamic model cell and experiments in brain slices. The AECVC method provides an entirely digital method to perform continuous recording and smooth switching between voltage-clamp, current clamp or dynamic-clamp configurations without introducing artifacts.

  2. Microelectrode Array-evaluation of Neurotoxic Effects of Magnesium as an Implantable Biomaterial.

    Science.gov (United States)

    Huang, Ting; Wang, Zhonghai; Wei, Lina; Kindy, Mark; Zheng, Yufeng; Xi, Tingfei; Gao, Bruce Z

    2016-01-01

    Magnesium (Mg)-based biomaterials have shown great potential in clinical applications. However, the cytotoxic effects of excessive Mg 2+ and the corrosion products from Mg-based biomaterials, particularly their effects on neurons, have been little studied. Although viability tests are most commonly used, a functional evaluation is critically needed. Here, both methyl thiazolyl tetrazolium (MTT) and lactate dehydrogenase (LDH) assays were used to test the effect of Mg 2+ and Mg-extract solution on neuronal viability. Microelectrode arrays (MEAs), which provide long-term, real-time recording of extracellular electrophysiological signals of in vitro neuronal networks, were used to test for toxic effects. The minimum effective concentrations (EC min ) of Mg 2+ from the MTT and LDH assays were 3 mmol/L and 100 mmol/L, respectively, while the EC min obtained from the MEA assay was 0.1 mmol/L. MEA data revealed significant loss of neuronal network activity when the culture was exposed to 25% Mg-extract solution, a concentration that did not affect neuronal viability. For evaluating the biocompatibility of Mg-based biomaterials with neurons, MEA electrophysiological testing is a more precise method than basic cell-viability testing.

  3. An iridium oxide microelectrode for monitoring acute local pH changes of endothelial cells.

    Science.gov (United States)

    Ng, Shu Rui; O'Hare, Danny

    2015-06-21

    pH sensors were fabricated by anodically electrodepositing iridium oxide films (AEIROFs) onto microelectrodes on chips and coated with poly(ethyleneimine) (PEI) for mechanical stability. These demonstrate super-Nernstian response to pH from pH 4.0 to 7.7 in chloride-free phosphate buffer. The surface of the chip was coated with fibronectin for the attachment of porcine aortic endothelial cells (PAECs). The working capability of the pH sensor for monitoring acute local pH changes was investigated by stimulating the PAECs with thrombin. Our results show that thrombin induced acute extracellular acidification of PAECs and dissolution of fibronectin, causing the local pH to decrease. The use of PD98059, a mitogen-activated protein kinase (MAPK) inhibitor, reduced extracellular acidification and an increase in local pH was observed. This study shows that our pH sensors can facilitate the investigation of acute cellular responses to stimulation by monitoring the real-time, local pH changes of cells attached to the sensors.

  4. An implantable integrated low-power amplifier-microelectrode array for Brain-Machine Interfaces.

    Science.gov (United States)

    Patrick, Erin; Sankar, Viswanath; Rowe, William; Sanchez, Justin C; Nishida, Toshikazu

    2010-01-01

    One of the important challenges in designing Brain-Machine Interfaces (BMI) is to build implantable systems that have the ability to reliably process the activity of large ensembles of cortical neurons. In this paper, we report the design, fabrication, and testing of a polyimide-based microelectrode array integrated with a low-power amplifier as part of the Florida Wireless Integrated Recording Electrode (FWIRE) project at the University of Florida developing a fully implantable neural recording system for BMI applications. The electrode array was fabricated using planar micromachining MEMS processes and hybrid packaged with the amplifier die using a flip-chip bonding technique. The system was tested both on bench and in-vivo. Acute and chronic neural recordings were obtained from a rodent for a period of 42 days. The electrode-amplifier performance was analyzed over the chronic recording period with the observation of a noise floor of 4.5 microVrms, and an average signal-to-noise ratio of 3.8.

  5. Rapid Detection Technology for Pesticides Residues Based on Microelectrodes Impedance Immunosensor

    Directory of Open Access Journals (Sweden)

    Wen Ping Zhao

    2014-09-01

    Full Text Available Compared with conventional methods, electrochemical immunosensors have many advantages, such as low cost, high sensitivity, and rapid detection, and has certain prospects for realizing real-time-monitoring. In this paper, a design of portable pesticide residues detection instrument was presented based on an electrochemical impedance immunosensor. Firstly, we studied on an impedance immunosensor based on interdigitated array microelectrode (IDAM coupled with magnetic nanobeads-antibody conjugates (MNAC for the pesticide detection. Magnetic nanobeads (diameter 150 nm coated with anti-carbofuran antibodies were used for further amplification of the binding reaction between antibody and hapten (carbofuran. Secondly, in order to develop a portable pesticide residue apparatus, we designed the impedance detection electric circuit. Main work included designing and constructing of the system circuit, designing and debugging of the system software and so on. Thirdly, the apparatus was used for the standard pesticides solutions testing combined with immunosensor to test the reliability and stability. The pesticide added standard recovery was more than 70 % and the impedance test error was less than 5 %. The results showed that the proposed instrument had a good consistence compared with the traditional analytical methods. Thus, it would be a promising rapid detection instrument for pesticide residues in agricultural products.

  6. Brain Computer Interface Learning for Systems Based on Electrocorticography and Intracortical Microelectrode Arrays

    Directory of Open Access Journals (Sweden)

    Shivayogi V Hiremath

    2015-06-01

    Full Text Available A brain-computer interface (BCI system transforms neural activity into control signals for external devices in real time. A BCI user needs to learn to generate specific cortical activity patterns to control external devices effectively. We call this process BCI learning, and it often requires significant effort and time. Therefore, it is important to study this process and develop novel and efficient approaches to accelerate BCI learning. This article reviews major approaches that have been used for BCI learning, including computer-assisted learning, co-adaptive learning, operant conditioning, and sensory feedback. We focus on BCIs based on electrocorticography and intracortical microelectrode arrays for restoring motor function. This article also explores the possibility of brain modulation techniques in promoting BCI learning, such as electrical cortical stimulation, transcranial magnetic stimulation, and optogenetics. Furthermore, as proposed by recent BCI studies, we suggest that BCI learning is in many ways analogous to motor and cognitive skill learning, and therefore skill learning should be a useful metaphor to model BCI learning.

  7. ZnO crystal growth on microelectrode by electrochemical deposition method

    International Nuclear Information System (INIS)

    Kondo, Y; Ashida, A; Nouzu, N; Fujimura, N

    2011-01-01

    Zinc Oxide crystals were grown by constant potential electrochemical deposition method on the substrate with the Pt working electrode which consists of Pt film with large area and μm-sized line and space structured area. In case of depositions with cathodic potential of -0.3V, ZnO crystal is not observed on the micro electrode, but observed on the electrode with large area (0.2 cm 2 ). By using electrolyte with higher pH, ZnO crystal grows on both areas. In case of lower pH, ZnO crystal does not grow on either. From these results, the pH range for growth of ZnO on the microelectrode seems to be higher than that on the electrode with large area. And, it is expected that the pH just on the surface of μm-sized electrode is lower than that in the bulk of electrolyte. Based on these results, it can be concluded that control of the pH in vicinity of the surface is very important to ECD method for micro- and nano-scaled devices.

  8. Brain computer interface learning for systems based on electrocorticography and intracortical microelectrode arrays.

    Science.gov (United States)

    Hiremath, Shivayogi V; Chen, Weidong; Wang, Wei; Foldes, Stephen; Yang, Ying; Tyler-Kabara, Elizabeth C; Collinger, Jennifer L; Boninger, Michael L

    2015-01-01

    A brain-computer interface (BCI) system transforms neural activity into control signals for external devices in real time. A BCI user needs to learn to generate specific cortical activity patterns to control external devices effectively. We call this process BCI learning, and it often requires significant effort and time. Therefore, it is important to study this process and develop novel and efficient approaches to accelerate BCI learning. This article reviews major approaches that have been used for BCI learning, including computer-assisted learning, co-adaptive learning, operant conditioning, and sensory feedback. We focus on BCIs based on electrocorticography and intracortical microelectrode arrays for restoring motor function. This article also explores the possibility of brain modulation techniques in promoting BCI learning, such as electrical cortical stimulation, transcranial magnetic stimulation, and optogenetics. Furthermore, as proposed by recent BCI studies, we suggest that BCI learning is in many ways analogous to motor and cognitive skill learning, and therefore skill learning should be a useful metaphor to model BCI learning.

  9. Modulation of cultured neural networks using neurotrophin release from hydrogel-coated microelectrode arrays

    Science.gov (United States)

    Jun, Sang Beom; Hynd, Matthew R.; Dowell-Mesfin, Natalie M.; Al-Kofahi, Yousef; Roysam, Badrinath; Shain, William; Kim, Sung June

    2008-06-01

    Polyacrylamide and poly(ethylene glycol) diacrylate hydrogels were synthesized and characterized for use as drug release and substrates for neuron cell culture. Protein release kinetics was determined by incorporating bovine serum albumin (BSA) into hydrogels during polymerization. To determine if hydrogel incorporation and release affect bioactivity, alkaline phosphatase was incorporated into hydrogels and a released enzyme activity determined using the fluorescence-based ELF-97 assay. Hydrogels were then used to deliver a brain-derived neurotrophic factor (BDNF) from hydrogels polymerized over planar microelectrode arrays (MEAs). Primary hippocampal neurons were cultured on both control and neurotrophin-containing hydrogel-coated MEAs. The effect of released BDNF on neurite length and process arborization was investigated using automated image analysis. An increased spontaneous activity as a response to the released BDNF was recorded from the neurons cultured on the top of hydrogel layers. These results demonstrate that proteins of biological interest can be incorporated into hydrogels to modulate development and function of cultured neural networks. These results also set the stage for development of hydrogel-coated neural prosthetic devices for local delivery of various biologically active molecules.

  10. A microelectrode array electrodeposited with reduced graphene oxide and Pt nanoparticles for norepinephrine and electrophysiological recordings

    Science.gov (United States)

    Wang, Li; Song, Yilin; Zhang, Yu; Xu, Shengwei; Xu, Huiren; Wang, Mixia; Wang, Yang; Cai, Xinxia

    2017-11-01

    Norepinephrine (NE), a common neurotransmitter released by locus coeruleus neurons, plays an essential role in the communication mechanism of the mammalian nervous system. In this work, a microelectrode array (MEA) was fabricated by micro-electromechanical system (MEMS) technology to provide a rapid, sensitive and reliable method for the direct determination in NE dynamic secretion. To improve the electrical performance, the MEA was electrodeposited with the reduced graphene oxide and Pt nanoparticles (rGOPNps). rGOPNps-MEA was investigated using scanning electron microscopy, atomic force microscopy and electrochemical impedance spectroscopy, differential pulse voltammetry exhibited remarkably electrocatalytic properties towards NE. Calibration results showed a sensitivity of 1.03 nA µM-1 to NE with a detection limit of 0.08 µM. In Particular, the MEA was successfully used for measuring dynamic extracellular NE secretion from the locus coeruleus brain slice, as well as monitoring spike firing from the hippocampal brain slice. This fabricated device has potential in studies of spatially resolved delivery of trace neurochemicals and electrophysiological activities of a variety of biological tissues in vitro.

  11. Outcomes of Interventional-MRI Versus Microelectrode Recording-Guided Subthalamic Deep Brain Stimulation

    Directory of Open Access Journals (Sweden)

    Philip S. Lee

    2018-04-01

    Full Text Available In deep brain stimulation (DBS of the subthalamic nucleus (STN for Parkinson’s disease (PD, there is debate concerning the use of neuroimaging alone to confirm correct anatomic placement of the DBS lead into the STN, versus the use of microelectrode recording (MER to confirm functional placement. We performed a retrospective study of a contemporaneous cohort of 45 consecutive patients who underwent either interventional-MRI (iMRI or MER-guided DBS lead implantation. We compared radial lead error, motor and sensory side effect, and clinical benefit programming thresholds, and pre- and post-operative unified PD rating scale scores, and levodopa equivalent dosages. MER-guided surgery was associated with greater radial error compared to the intended target. In general, side effect thresholds during initial programming were slightly lower in the MER group, but clinical benefit thresholds were similar. No significant difference in the reduction of clinical symptoms or medication dosage was observed. In summary, iMRI lead implantation occurred with greater anatomic accuracy, in locations demonstrated to be the appropriate functional region of the STN, based on the observation of similar programming side effect and benefit thresholds obtained with MER. The production of equivalent clinical outcomes suggests that surgeon and patient preference can be used to guide the decision of whether to recommend iMRI or MER-guided DBS lead implantation to appropriate patients with PD.

  12. Amperometric Self-Referencing Ceramic Based Microelectrode Arrays for D-Serine Detection.

    Science.gov (United States)

    Campos-Beltrán, Diana; Konradsson-Geuken, Åsa; Quintero, Jorge E; Marshall, Lisa

    2018-03-06

    D-serine is the major D-amino acid in the mammalian central nervous system. As the dominant co-agonist of the endogenous synaptic NMDA receptor, D-serine plays a role in synaptic plasticity, learning, and memory. Alterations in D-serine are linked to neuropsychiatric disorders including schizophrenia. Thus, it is of increasing interest to monitor the concentration of D-serine in vivo as a relevant player in dynamic neuron-glia network activity. Here we present a procedure for amperometric detection of D-serine with self-referencing ceramic-based microelectrode arrays (MEAs) coated with D-amino acid oxidase from the yeast Rhodotorula gracilis (RgDAAO). We demonstrate in vitro D-serine recordings with a mean sensitivity of 8.61 ± 0.83 pA/µM to D-serine, a limit of detection (LOD) of 0.17 ± 0.01 µM, and a selectivity ratio of 80:1 or greater for D-serine over ascorbic acid (mean ± SEM; n = 12) that can be used for freely moving studies.

  13. Depth-time interpolation of feature trends extracted from mobile microelectrode data with kernel functions.

    Science.gov (United States)

    Wong, Stephen; Hargreaves, Eric L; Baltuch, Gordon H; Jaggi, Jurg L; Danish, Shabbar F

    2012-01-01

    Microelectrode recording (MER) is necessary for precision localization of target structures such as the subthalamic nucleus during deep brain stimulation (DBS) surgery. Attempts to automate this process have produced quantitative temporal trends (feature activity vs. time) extracted from mobile MER data. Our goal was to evaluate computational methods of generating spatial profiles (feature activity vs. depth) from temporal trends that would decouple automated MER localization from the clinical procedure and enhance functional localization in DBS surgery. We evaluated two methods of interpolation (standard vs. kernel) that generated spatial profiles from temporal trends. We compared interpolated spatial profiles to true spatial profiles that were calculated with depth windows, using correlation coefficient analysis. Excellent approximation of true spatial profiles is achieved by interpolation. Kernel-interpolated spatial profiles produced superior correlation coefficient values at optimal kernel widths (r = 0.932-0.940) compared to standard interpolation (r = 0.891). The choice of kernel function and kernel width resulted in trade-offs in smoothing and resolution. Interpolation of feature activity to create spatial profiles from temporal trends is accurate and can standardize and facilitate MER functional localization of subcortical structures. The methods are computationally efficient, enhancing localization without imposing additional constraints on the MER clinical procedure during DBS surgery. Copyright © 2012 S. Karger AG, Basel.

  14. Boron-doped nanocrystalline diamond microelectrode arrays monitor cardiac action potentials.

    Science.gov (United States)

    Maybeck, Vanessa; Edgington, Robert; Bongrain, Alexandre; Welch, Joseph O; Scorsone, Emanuel; Bergonzo, Philippe; Jackman, Richard B; Offenhäusser, Andreas

    2014-02-01

    The expansion of diamond-based electronics in the area of biological interfacing has not been as thoroughly explored as applications in electrochemical sensing. However, the biocompatibility of diamond, large safe electrochemical window, stability, and tunable electronic properties provide opportunities to develop new devices for interfacing with electrogenic cells. Here, the fabrication of microelectrode arrays (MEAs) with boron-doped nanocrystalline diamond (BNCD) electrodes and their interfacing with cardiomyocyte-like HL-1 cells to detect cardiac action potentials are presented. A nonreductive means of structuring doped and undoped diamond on the same substrate is shown. The resulting BNCD electrodes show high stability under mechanical stress generated by the cells. It is shown that by fabricating the entire surface of the MEA with NCD, in patterns of conductive doped, and isolating undoped regions, signal detection may be improved up to four-fold over BNCD electrodes passivated with traditional isolators. Copyright © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Porous-microelectrode study on Pt/C catalysts for methanol electrooxidation

    International Nuclear Information System (INIS)

    Umeda, Minoru; Kokubo, Mitsuhiro; Mohamedi, Mohamed; Uchida, Isamu

    2003-01-01

    We have developed a porous-microelectrode (PME) to investigate the electroactivity of catalyst particles for proton exchange membrane fuel cells. The cavity at the tip of the PME was filled with Pt/C catalysts prepared by impregnation method. Cyclic voltammograms (CVs) recorded in 1 N H 2 SO 4 aqueous solution revealed that the active area of the stacked catalysts exist not only at the surface but also inside of the stack. For methanol electrooxidation, 30 wt.% Pt/C exhibited the highest electroactivity, whereas the 50 wt.% Pt/C showed extremely small current. The small current is considered as a result of a small active-surface area. Methanol oxidation peak potential shifted toward cathodic direction as Pt-loading decreased, which agrees well with the Pt-oxide formation potential. The activation energy for methanol oxidation was assessed to be 44±3 kJ mol -1 for all Pt/C catalysts and Pt-disc electrode

  16. Te/Pt nanonetwork modified carbon fiber microelectrodes for methanol oxidation

    International Nuclear Information System (INIS)

    Tsai, Hsiang-Yu; Shih, Zih-Yu; Lin, Zong-Hong; Chang, Huan-Tsung

    2013-01-01

    Te/Pt nanonetwork-decorated carbon fiber microelectrodes (CFMEs) have been fabricated and employed as anodic catalysts in a direct methanol fuel cell (DMFC). Te nanowires were prepared from tellurite ions (TeO 3 2− ) through a seed-mediated growth process and were deposited onto CFMEs to form three-dimensional Te nanonetworks. The Te nanonetworks then acted as a framework and reducing agent to reduce PtCl 6 2− ions to form Te/Pt through a galvanic replacement reaction, leading to the formation of Te/PtCFMEs. By controlling the reaction time, the amount of Pt and morphology of Te/Pt nanonetworks were controlled, leading to various degrees of electrocatalytic activity. The Te/PtCFMEs provide a high electrochemical active surface area (129.2 m 2 g −1 ), good catalytic activity (1.2 A mg −1 ), high current density (20.0 mA cm −2 ), long durability, and tolerance toward the poisoning species for methanol oxidation in 0.5 M sulfuric acid containing 1 M methanol. We have further demonstrated an enhanced current density by separately using 3 and 5 Te/PtCFMEs. Our results show that the low-cost, stable, and effective Te/PtCFMEs have great potential in the fabrication of cost-effective fuel cells. (paper)

  17. Wearable Multi-Channel Microelectrode Membranes for Elucidating Electrophysiological Phenotypes of Injured Myocardium

    Science.gov (United States)

    Cao, Hung; Yu, Fei; Zhao, Yu; Zhang, Xiaoxiao; Tai, Joyce; Lee, Juhyun; Darehzereshki, Ali; Bersohn, Malcolm; Lien, Ching-Ling; Chi, Neil C.; Tai, Yu-Chong; Hsiai, Tzung K.

    2014-01-01

    Understanding the regenerative capacity of small vertebrate models has provided new insights into the plasticity of injured myocardium. Here, we demonstrated the application of flexible microelectrode arrays (MEAs) in elucidating electrophysiological phenotypes of zebrafish and neonatal mouse models of heart regeneration. The 4-electrode MEA membranes were designed to detect electrical signals in the aquatic environment. They were micro-fabricated to adhere to the non-planar body surface of zebrafish and neonatal mice. The acquired signals were processed to display electrocardiogram (ECG) with high signal-to-noise-ratios, and were validated via the use of conventional micro-needle electrodes. The 4-channel MEA provided signal stability and spatial resolution, revealing the site-specific electrical injury currents such as ST-depression in response to ventricular cryo-injury. Thus, our polymer-based and wearable MEA membranes provided electrophysiological insights in long-term conduction phenotypes for small vertebral models of heart injury and regeneration with a translational implication for monitoring cardiac patients. PMID:24945366

  18. Interdigitated microelectrode based impedance biosensor for detection of salmonella enteritidis in food samples

    Energy Technology Data Exchange (ETDEWEB)

    Kim, G [National Institute of Agricultural Engineering, 249 Seodun-dong, Suwon, Republic of Korea, 441-100 (Korea, Republic of); Morgan, M; Hahm, B K; Bhunia, A [Department of Food Science, Purdue University, West Lafayette, IN 47907 (United States); Mun, J H; Om, A S [Department of Food and Nutrient, Hanyang University, 17 Haengdang-dong, Seoul, Republic of Korea, 133-791 (Korea, Republic of)], E-mail: giyoungkim@rda.go.kr

    2008-03-15

    Salmonella enteritidis outbreaks continue to occur, and S. enteritidis-related outbreaks from various food sources have increased public awareness of this pathogen. Conventional methods for pathogens detection and identification are labor-intensive and take days to complete. Some immunological rapid assays are developed, but these assays still require prolonged enrichment steps. Recently developed biosensors have shown great potential for the rapid detection of foodborne pathogens. To develop the biosensor, an interdigitated microelectrode (IME) was fabricated by using semiconductor fabrication process. Anti-Salmonella antibodies were immobilized based on avidin-biotin binding on the surface of the IME to form an active sensing layer. To increase the sensitivity of the sensor, three types of sensors that have different electrode gap sizes (2 {mu}m, 5 {mu}m, 10 {mu}m) were fabricated and tested. The impedimetric biosensor could detect 10{sup 3} CFU/mL of Salmonella in pork meat extract with an incubation time of 5 minutes. This method may provide a simple, rapid and sensitive method to detect foodborne pathogens.

  19. Highly sensitive three-dimensional interdigitated microelectrode for microparticle detection using electrical impedance spectroscopy

    International Nuclear Information System (INIS)

    Chang, Fu-Yu; Chen, Ming-Kun; Jang, Ling-Sheng; Wang, Min-Haw

    2016-01-01

    Cell impedance analysis is widely used for monitoring biological and medical reactions. In this study, a highly sensitive three-dimensional (3D) interdigitated microelectrode (IME) with a high aspect ratio on a polyimide (PI) flexible substrate was fabricated for microparticle detection (e.g. cell quantity detection) using electroforming and lithography technology. 3D finite element simulations were performed to compare the performance of the 3D IME (in terms of sensitivity and signal-to-noise ratio) to that of a planar IME for particles in the sensing area. Various quantities of particles were captured in Dulbecco’s modified Eagle medium and their impedances were measured. With the 3D IME, the particles were arranged in the gap, not on the electrode, avoiding the noise due to particle position. For the maximum particle quantities, the results show that the 3D IME has at least 5-fold higher sensitivity than that of the planar IME. The trends of impedance magnitude and phase due to particle quantity were verified using the equivalent circuit model. The impedance (1269 Ω) of 69 particles was used to estimate the particle quantity (68 particles) with 98.6% accuracy using a parabolic regression curve at 500 kHz. (paper)

  20. Bioelectronic tongue of taste buds on microelectrode array for salt sensing.

    Science.gov (United States)

    Liu, Qingjun; Zhang, Fenni; Zhang, Diming; Hu, Ning; Wang, Hua; Hsia, K Jimmy; Wang, Ping

    2013-02-15

    Taste has received great attention for its potential applications. In this work, we combine the biological tissue with micro-chips to establish a novel bioelectronic tongue system for salt taste detection. Before experiment, we established a computational model of action potential in salt taste receptor cell, simulating the responsive results to natural salt stimuli of NaCl solution with various concentrations. Then 36-channel microelectrode arrays (MEA) with the diameter of 30 μm were fabricated on the glass substrate, and taste epithelium was stripped from rat and fixed on MEA. When stimulated by the salt stimuli, electrophysiological activities of taste receptor cells in taste buds were measured through a multi-channel recording system. Both simulation and experiment results showed a dose-dependent increase in NaCl-induced potentials of taste receptor cells, which indicated good applications in salt measurements. The multi-channel analysis demonstrated that different groups of MEA channels were activated during stimulations, indicating non-overlapping populations of receptor cells in taste buds involved in salt taste perception. The study provides an effective and reliable biosensor platform to help recognize and distinguish salt taste components. Copyright © 2012 Elsevier B.V. All rights reserved.

  1. The relationship between borderline personality disorder and bipolar disorder

    Science.gov (United States)

    Zimmerman, Mark; Morgan, Theresa A.

    2013-01-01

    It is clinically important to recognize both bipolar disorder and borderline personality disorder (BPD) in patients seeking treatment for depression, and it is important to distinguish between the two. Research considering whether BPD should be considered part of a bipolar spectrum reaches differing conclusions. We reviewed the most studied question on the relationship between BPD and bipolar disorder: their diagnostic concordance. Across studies, approximately 10% of patients with BPD had bipolar I disorder and another 10% had bipolar II disorder. Likewise, approximately 20% of bipolar II patients were diagnosed with BPD, though only 10% of bipolar I patients were diagnosed with BPD. While the comorbidity rates are substantial, each disorder is nontheless diagnosed in the absence of the other in the vast majority of cases (80% to 90%). In studies examining personality disorders broadly, other personality disorders were more commonly diagnosed in bipolar patients than was BPD. Likewise, the converse is also true: other axis I disorders such as major depression, substance abuse, and post-traumatic stress disorder are also more commonly diagnosed in patients with BPD than is bipolar disorder. These findings challenge the notion that BPD is part of the bipolar spectrum. PMID:24174890

  2. Thwarted interpersonal needs and suicide ideation: Comparing psychiatric inpatients with bipolar and non-bipolar mood disorders.

    Science.gov (United States)

    Taylor, Nathanael J; Mitchell, Sean M; Roush, Jared F; Brown, Sarah L; Jahn, Danielle R; Cukrowicz, Kelly C

    2016-12-30

    Psychiatric inpatients are at heightened risk for suicide, and evidence suggests that psychiatric inpatients with bipolar mood disorders may be at greater risk for suicide ideation compared to those with non-bipolar mood disorders. There is a paucity of research directly comparing risk factors for suicide ideation in bipolar versus non-bipolar mood disorders in an inpatient sample. The current study sought to clarify the association between two constructs from the interpersonal theory of suicide (i.e., perceived burdensomeness and thwarted belongingness) in leading to suicide ideation among psychiatric inpatients with bipolar and non-bipolar mood disorders. Participants were (N=90) psychiatric inpatients with a bipolar (n = 20) or non-bipolar mood disorder (n=70; per their medical charts). Perceived burdensomeness, but not thwarted belongingness, was significantly associated with suicide ideation after adjusting for other covariates. This suggests perceived burdensomeness may play a key role in suicide ideation among psychiatric inpatients with any mood disorder and highlights the importance of assessment and intervention of perceived burdensomeness in this population. Contrary to our hypothesis, mood disorder group (i.e., bipolar versus non-bipolar) did not moderate the relations between perceived burdensomeness/thwarted belongingness and suicide ideation. Published by Elsevier Ireland Ltd.

  3. Systematic review of the prevalence of bipolar disorder and bipolar spectrum disorders in population-based studies

    Directory of Open Access Journals (Sweden)

    José Caetano Dell'Aglio Jr.

    2013-01-01

    Full Text Available This paper describes the findings of a systematic literature review aimed at providing an overview of the lifetime prevalence of bipolar disorder and bipolar spectrum disorders in population-based studies. Databases MEDLINE, ProQuest, Psychnet, and Web of Science were browsed for papers published in English between 1999 and May 2012 using the following search string: bipolar disorders OR bipolar spectrum disorders AND prevalence OR cross-sectional OR epidemiology AND population-based OR non-clinical OR community based. The search yielded a total of 434 papers, but only those published in peer-reviewed journals and with samples aged ≥ 18 years were included, resulting in a final sample of 18 papers. Results revealed rather heterogeneous findings concerning the prevalence of bipolar disorders and bipolar spectrum disorders. Lifetime prevalence of bipolar disorder ranged from 0.1 to 7.5%, whereas lifetime prevalence of bipolar spectrum disorders ranged from 2.4 to 15.1%. Differences in the rates of bipolar disorder and bipolar spectrum disorders may be related to the consideration of subthreshold criteria upon diagnosis. Differences in the prevalence of different subtypes of the disorder are discussed in light of diagnostic criteria and instruments applied.

  4. Abordagens psicoterápicas no transtorno bipolar Psychoterapeutic approach in bipolar disorder

    Directory of Open Access Journals (Sweden)

    Paulo Knapp

    2005-01-01

    Full Text Available Embora o tratamento farmacológico seja essencial para o tratamento do transtorno bipolar, apenas 40% de todos os pacientes que aderem às medicações permanecem assintomáticos durante o período de seguimento, o que tem levado ao desenvolvimento de intervenções psicoterápicas associadas. O objetivo deste artigo é examinar as evidências atuais da eficácia de intervenções psicoterápicas no tratamento do transtorno bipolar. Foi realizada uma pesquisa bibliográfica por meio do MedLine, PsychoINFO, Lilacs e Cochrane Data Bank, até o ano de 2004, em que foram procurados artigos originais e revisões sobre as abordagens psicoterápicas utilizadas no tratamento do transtorno bipolar. Há várias abordagens que podem se mostrar úteis no tratamento do transtorno bipolar. A psicoeducação e a terapia cognitivo-comportamental apresentam as evidências mais consistentes e são as técnicas mais amplamente estudadas. As intervenções envolvendo familiares e a terapia interpessoal e de ritmo social se mostram tratamentos eficazes em determinadas situações. Há alguns estudos empregando a terapia psicodinâmica no transtorno bipolar, mas são estudos com limitações metodológicas. Apesar de haver evidências demonstrando a eficácia de determinadas abordagens psicoterápicas no transtorno bipolar, ainda é necessária a realização de estudos posteriores que comprovem tais dados e que desenvolvam tratamentos baseados em modelos etiológicos e que identifiquem tratamentos específicos para as diferentes fases e tipos de transtorno bipolar.Although pharmacological treatment is essential for treating bipolar disorder, less than half of all medication compliant patients are non-symptomatic during follow-up, which has led to developments of adjunctive psychosocial interventions. This paper examines the current evidence for effectiveness of psychotherapeutic interventions in the treatment of bipolar disorder. Searches were undertaken through Med

  5. Clinical status of comorbid bipolar disorder and borderline personality disorder.

    Science.gov (United States)

    Parker, Gordon; Bayes, Adam; McClure, Georgia; Del Moral, Yolanda Romàn Ruiz; Stevenson, Janine

    2016-09-01

    The status and differentiation of comorbid borderline personality disorder and bipolar disorder is worthy of clarification. To determine whether comorbid borderline personality disorder and bipolar disorder are interdependent or independent conditions. We interviewed patients diagnosed with either a borderline personality disorder and/or a bipolar condition. Analyses of participants grouped by DSM diagnoses established that those with comorbid conditions scored similarly to those with a borderline personality disorder alone on all key variables (i.e. gender, severity of borderline personality scores, developmental stressors, illness correlates, self-injurious behaviour rates) and differed from those with a bipolar disorder alone on nearly all non-bipolar item variables. Similar findings were returned for groups defined by clinical diagnoses. Comorbid bipolar disorder and borderline personality disorder is consistent with the formal definition of comorbidity in that, while coterminous, individuals meeting such criteria have features of two independent conditions. © The Royal College of Psychiatrists 2016.

  6. Storm in My Brain: Kids and Mood Disorders (Bipolar Disorder and Depression)

    Science.gov (United States)

    ... Brain Kids and Mood Disorders (Bipolar Disorder and Depression) What is a mood disorder? Everyone feels sad, ... one part of bipolar disorder, also called manic depression. In bipolar disorder, moods change between mania (excited ...

  7. Spontaneous and Evoked Activity from Murine Ventral Horn Cultures on Microelectrode Arrays

    Directory of Open Access Journals (Sweden)

    Bryan J. Black

    2017-09-01

    Full Text Available Motor neurons are the site of action for several neurological disorders and paralytic toxins, with cell bodies located in the ventral horn (VH of the spinal cord along with interneurons and support cells. Microelectrode arrays (MEAs have emerged as a high content assay platform for mechanistic studies and drug discovery. Here, we explored the spontaneous and evoked electrical activity of VH cultures derived from embryonic mouse spinal cord on multi-well plates of MEAs. Primary VH cultures from embryonic day 15–16 mice were characterized by expression of choline acetyltransferase (ChAT by immunocytochemistry. Well resolved, all-or-nothing spontaneous spikes with profiles consistent with extracellular action potentials were observed after 3 days in vitro, persisting with consistent firing rates until at least day in vitro 19. The majority of the spontaneous activity consisted of tonic firing interspersed with coordinated bursting across the network. After 5 days in vitro, spike activity was readily evoked by voltage pulses where a minimum amplitude and duration required for excitation was 300 mV and 100 μs/phase, respectively. We characterized the sensitivity of spontaneous and evoked activity to a host of pharmacological agents including AP5, CNQX, strychnine, ω-agatoxin IVA, and botulinum neurotoxin serotype A (BoNT/A. These experiments revealed sensitivity of the cultured VH to both agonist and antagonist compounds in a manner consistent with mature tissue derived from slices. In the case of BoNT/A, we also demonstrated intoxication persistence over an 18-day period, followed by partial intoxication recovery induced by N- and P/Q-type calcium channel agonist GV-58. In total, our findings suggest that VH cultures on multi-well MEA plates may represent a moderate throughput, high content assay for performing mechanistic studies and for screening potential therapeutics pertaining to paralytic toxins and neurological disorders.

  8. Multivariate regression methods for estimating velocity of ictal discharges from human microelectrode recordings

    Science.gov (United States)

    Liou, Jyun-you; Smith, Elliot H.; Bateman, Lisa M.; McKhann, Guy M., II; Goodman, Robert R.; Greger, Bradley; Davis, Tyler S.; Kellis, Spencer S.; House, Paul A.; Schevon, Catherine A.

    2017-08-01

    Objective. Epileptiform discharges, an electrophysiological hallmark of seizures, can propagate across cortical tissue in a manner similar to traveling waves. Recent work has focused attention on the origination and propagation patterns of these discharges, yielding important clues to their source location and mechanism of travel. However, systematic studies of methods for measuring propagation are lacking. Approach. We analyzed epileptiform discharges in microelectrode array recordings of human seizures. The array records multiunit activity and local field potentials at 400 micron spatial resolution, from a small cortical site free of obstructions. We evaluated several computationally efficient statistical methods for calculating traveling wave velocity, benchmarking them to analyses of associated neuronal burst firing. Main results. Over 90% of discharges met statistical criteria for propagation across the sampled cortical territory. Detection rate, direction and speed estimates derived from a multiunit estimator were compared to four field potential-based estimators: negative peak, maximum descent, high gamma power, and cross-correlation. Interestingly, the methods that were computationally simplest and most efficient (negative peak and maximal descent) offer non-inferior results in predicting neuronal traveling wave velocities compared to the other two, more complex methods. Moreover, the negative peak and maximal descent methods proved to be more robust against reduced spatial sampling challenges. Using least absolute deviation in place of least squares error minimized the impact of outliers, and reduced the discrepancies between local field potential-based and multiunit estimators. Significance. Our findings suggest that ictal epileptiform discharges typically take the form of exceptionally strong, rapidly traveling waves, with propagation detectable across millimeter distances. The sequential activation of neurons in space can be inferred from clinically

  9. Cell culture chamber with gas supply for prolonged recording of human neuronal cells on microelectrode array.

    Science.gov (United States)

    Kreutzer, Joose; Ylä-Outinen, Laura; Mäki, Antti-Juhana; Ristola, Mervi; Narkilahti, Susanna; Kallio, Pasi

    2017-03-15

    Typically, live cell analyses are performed outside an incubator in an ambient air, where the lack of sufficient CO 2 supply results in a fast change of pH and the high evaporation causes concentration drifts in the culture medium. That limits the experiment time for tens of minutes. In many applications, e.g. in neurotoxicity studies, a prolonged measurement of extracellular activity is, however, essential. We demonstrate a simple cell culture chamber that enables stable culture conditions during prolonged extracellular recordings on a microelectrode array (MEA) outside an incubator. The proposed chamber consists of a gas permeable silicone structure that enables gas transfer into the chamber. We show that the culture chamber supports the growth of the human embryonic stem cell (hESC)-derived neurons both inside and outside an incubator. The structure provides very low evaporation, stable pH and osmolarity, and maintains strong signaling of hESC-derived neuronal networks over three-day MEA experiments. Existing systems are typically complex including continuous perfusion of medium or relatively large amount of gas to supply. The proposed chamber requires only a supply of very low flow rate (1.5ml/min) of non-humidified 5% CO 2 gas. Utilizing dry gas supply makes the proposed chamber simple to use. Using the proposed culture structure on top of MEA, we can maintain hESC-derived neural networks over three days outside an incubator. Technically, the structure requires very low flow rate of dry gas supporting, however, low evaporation and maintaining the pH of the culture. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Udvikling af medicinsk behandling mod bipolar lidelse

    DEFF Research Database (Denmark)

    Ellegaard, Pernille Kempel

    2015-01-01

    Selvom Esbjerg ligger i vandkants Danmark, er det den Psykiatriske Forskningsenhed i denne by, der er primus motor for et stort forsøg blandt mennesker, der lider af bipolar lidelse. Forsøget hedder ”NACOS”, og er et medicinsk forsøg til mennesker, der befinder sig i den depressive fase.......Selvom Esbjerg ligger i vandkants Danmark, er det den Psykiatriske Forskningsenhed i denne by, der er primus motor for et stort forsøg blandt mennesker, der lider af bipolar lidelse. Forsøget hedder ”NACOS”, og er et medicinsk forsøg til mennesker, der befinder sig i den depressive fase....

  11. Does bipolar pacemaker current activate blood platelets?

    DEFF Research Database (Denmark)

    Gjesdal, Grunde; Hansen, Annebirthe Bo; Brandes, Axel

    2009-01-01

    OBJECTIVE: The aim of this study was to investigate whether bipolar pacemaker current lead can activate blood platelets. The null hypothesis was that 1 minute of electrical stimulation of platelets would not influence their subsequent reactivity to adenosine diphosphate (ADP). BACKGROUND: Both...... platelets and muscle cells contain actin and myosin filaments, and both cells are activated following calcium influx. Muscle cells open their calcium channels and contract when exposed to an electric current. Current through a bipolar pacemaker lead will expose a small volume of blood, including platelets......, to the depolarizing current. Platelet activation may ensue, resulting in aggregation, release reaction, and contraction. In contrast, a unipolar pacemaker system will not depolarize blood, but transmit current directly into the myocardium, and the current afterward passes through other tissues before returning...

  12. Faddeev wave function decomposition using bipolar harmonics

    International Nuclear Information System (INIS)

    Friar, J.L.; Tomusiak, E.L.; Gibson, B.F.; Payne, G.L.

    1981-01-01

    The standard partial wave (channel) representation for the Faddeev solution to the Schroedinger equation for the ground state of 3 nucleons is written in terms of functions which couple the interacting pair and spectator angular momenta to give S, P, and D waves. For each such coupling there are three terms, one for each of the three cyclic permutations of the nucleon coordinates. A series of spherical harmonic identities is developed which allows writing the Faddeev solution in terms of a basis set of 5 bipolar harmonics: 1 for S waves; 1 for P waves; and 3 for D waves. The choice of a D-wave basis is largely arbitrary, and specific choices correspond to the decomposition schemes of Derrick and Blatt, Sachs, Gibson and Schiff, and Bolsterli and Jezak. The bipolar harmonic form greatly simplifies applications which utilize the wave function, and we specifically discuss the isoscalar charge (or mass) density and the 3 He Coulomb energy

  13. Customization in prescribing for bipolar disorder.

    Science.gov (United States)

    Hodgkin, Dominic; Volpe-Vartanian, Joanna; Merrick, Elizabeth L; Horgan, Constance M; Nierenberg, Andrew A; Frank, Richard G; Lee, Sue

    2012-06-01

    For many disorders, patient heterogeneity requires physicians to customize their treatment to each patient's needs. We test for the existence of customization in physicians' prescribing for bipolar disorder, using data from a naturalistic clinical effectiveness trial of bipolar disorder treatment (STEP-BD), which did not constrain physician prescribing. Multinomial logit is used to model the physician's choice among five combinations of drug classes. We find that our observed measure of the patient's clinical status played only a limited role in the choice among drug class combinations, even for conditions such as mania that are expected to affect class choice. However, treatment of a patient with given characteristics differed widely depending on which physician was seen. The explanatory power of the model was low. There was variation within each physician's prescribing, but the results do not suggest a high degree of customization in physicians' prescribing, based on our measure of clinical status. Copyright © 2011 John Wiley & Sons, Ltd.

  14. Bipolar zinc/oxygen battery development

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, S [Paul Scherrer Inst. (PSI), Villigen (Switzerland); Schlatter, C [Swiss Federal Inst. of Technology, Lausanne (Switzerland)

    1997-06-01

    A bipolar electrically rechargeable Zn/O{sub 2} battery has been developed. Reticulated copper foam served as substrate for the zinc deposit on the anodic side, and La{sub 0.6}Ca{sub 0.4}CoO{sub 3}-catalyzed bifunctional oxygen electrodes were used on the cathodic side of the cells. The 100 cm{sup 2} unit cell had an open circuit voltage of 1,4 V(O{sub 2}) in moderately alkaline electrolyte. The open circuit voltage and the peak power measured for a stack containing seven cells were ca. 10V and 90W, respectively. The current-potential behaviour was determined as a function of the number of bipolar cells, and the maximum discharge capacity was determined at different discharge rates. (author) 4 figs., 1 ref.

  15. Suicide attempts and clinical features of bipolar patients

    OpenAIRE

    Berkol, Tongu? D.; ?slam, Serkan; K?rl?, Ebru; P?narba??, Rasim; ?zy?ld?r?m, ?lker

    2016-01-01

    Objectives: To identify clinical predictors of suicide attempts in patients with bipolar disorder. Methods: This study included bipolar patients who were treated in the Psychiatry Department, Haseki Training and Research Hospital, Istanbul, Turkey, between 2013 and 2014; an informed consent was obtained from the participants. Two hundred and eighteen bipolar patients were assessed by using the structured clinical interview for Diagnostic and Statistical Manual of Mental Disorders, 4th edition...

  16. Assessing and addressing cognitive impairment in bipolar disorder

    DEFF Research Database (Denmark)

    Miskowiak, K W; Burdick, K E; Martinez-Aran, A

    2018-01-01

    OBJECTIVES: Cognition is a new treatment target to aid functional recovery and enhance quality of life for patients with bipolar disorder. The International Society for Bipolar Disorders (ISBD) Targeting Cognition Task Force aimed to develop consensus-based clinical recommendations on whether, when...... in Bipolar Disorder Rating Assessment, and (III) evaluate the impact of medication and comorbidity, refer patients for comprehensive neuropsychological evaluation when clinically indicated, and encourage patients to build cognitive reserve. Regarding question (IV), there is limited evidence for current...

  17. Bipolar Disorder: What Can Psychotherapists Learn From the Cognitive Research?

    OpenAIRE

    Johnson, Sheri; Tran, Tanya

    2007-01-01

    Randomized controlled trials of psychological treatment, principally cognitive therapy, for bipolar disorder have yielded inconsistent results. Given the status of this evidentiary base, we provide a more fine-grained analysis of the cognitive profiles associated with bipolar disorder to inform clinical practice. In this practice-friendly review, we consider evidence that both negative and positive cognitive styles are related to bipolar disorder. Cross-sectional and prospective evidence sugg...

  18. Olfactocentric paralimbic cortex morphology in adolescents with bipolar disorder

    OpenAIRE

    Wang, Fei; Kalmar, Jessica H.; Womer, Fay Y.; Edmiston, Erin E.; Chepenik, Lara G.; Chen, Rachel; Spencer, Linda; Blumberg, Hilary P.

    2011-01-01

    The olfactocentric paralimbic cortex plays a critical role in the regulation of emotional and neurovegetative functions that are disrupted in core features of bipolar disorder. Adolescence is thought to be a critical period in both the maturation of the olfactocentric paralimbic cortex and in the emergence of bipolar disorder pathology. Together, these factors implicate a central role for the olfactocentric paralimbic cortex in the development of bipolar disorder and suggest that abnormalitie...

  19. High rate lithium/thionyl chloride bipolar battery development

    Science.gov (United States)

    Russell, P. G.; Goebel, F.

    The lithium/thionyl chloride ( {Li}/{SOCl2}) electrochemistry is capable of providing high power and high specific power, especially under pulse discharge conditions, when cells containing thin components are arranged in a bipolar configuration. This paper describes recent work concerned with bipolar cell design, cathode evaluation, component manufacturing methods, and the assembly and testing of bipolar modules containing up to 150 cells for Sonobuoy application.

  20. High rate lithium-thionyl chloride bipolar battery development

    Energy Technology Data Exchange (ETDEWEB)

    Russell, P.G.; Goebel, F. [Yardney Technical Products, Inc., Pawcatuck, CT (United States)

    1994-12-31

    The lithium/thionyl chloride system is capable of providing both high power and high energy density when cells containing thin components are arranged in a bipolar configuration. Electrode current densities in excess of 300mA/cm{sup 2} are achieved during pulse discharge. The present work is concerned with bipolar cell design, cathode evaluation, component manufacturing methods, and the assembly and testing of bipolar modules containing up to 150 cells.

  1. High rate lithium/thionyl chloride bipolar battery development

    Energy Technology Data Exchange (ETDEWEB)

    Russell, P.G. [Yardney Technical Products, Inc., Pawcatuck, CT (United States); Goebel, F. [Yardney Technical Products, Inc., Pawcatuck, CT (United States)

    1995-04-01

    The lithium/thionyl chloride (Li/SOCl{sub 2}) electrochemistry is capable of providing high power and high specific power, especially under pulse discharge conditions, when cells containing thin components are arranged in a bipolar configuration. This paper describes recent work concerned with bipolar cell design, cathode evaluation, component manufacturing methods, and the assembly and testing of bipolar modules containing up to 150 cells for Sonobuoy application. (orig.)

  2. The relationship between borderline personality disorder and bipolar disorder

    OpenAIRE

    Zimmerman, Mark; Morgan, Theresa A.

    2013-01-01

    It is clinically important to recognize both bipolar disorder and borderline personality disorder (BPD) in patients seeking treatment for depression, and it is important to distinguish between the two. Research considering whether BPD should be considered part of a bipolar spectrum reaches differing conclusions. We reviewed the most studied question on the relationship between BPD and bipolar disorder: their diagnostic concordance. Across studies, approximately 10% of patients with BPD had bi...

  3. The bipolar II disorder personality traits, a true syndrome?

    Science.gov (United States)

    Gudmundsson, Einar

    2015-06-01

    The author was struck by the similarities and commonality of complaints, aside from mood swings, made by Bipolar II patients and started registrating these complaints. This registrational work eventually led to the development of The Bipolar II Syndome Checklist. The aim of this work was to understand how widely the Bipolar II disorder affects the personality, and what disturbing personality traits are the most common? Deliberately, no attempt was made to diagnose psychiatric comorbidities, in the hope that one would get a clearer view of what symptoms, if any, could be considered a natural part of the Bipolar II Disorder. As far as the author knows this is a novel approach. 105 Bipolar II patients completed the Bipolar II Syndrome Checklist. The answers to the 44 questions on the list are presented in tables. Symptoms like anxiety, low self esteem, paranoia, extreme hurtfulness, migraine, Post Partum Depression, obsessive traits, alcoholism in the family are amongst the findings which will be presented in greater detail. No control group. Bipolar I patients excluded. The Bipolar II Syndrome Checklist has not been systematically validated. The results show that Bipolar II Disorder causes multiple symptoms so commonly that it may be justified to describe it as a syndrome, The Bipolar II Syndrome. Also these disturbances commonly lie in families of Bipolar II patients and are in all likelihood, greatly underdiagnosed. The clinical relevance of this study lies in increasing our knowledge and understanding of the nature of the Bipolar II Disorder, which in all probability will increase the diagnostic and treatment accuracy, since clinicians are more likely to scan for other symptoms needing treatment. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. Differential diagnosis of bipolar disorder and major depressive disorder.

    Science.gov (United States)

    Hirschfeld, R M

    2014-12-01

    Patients with bipolar disorder spend approximately half of their lives symptomatic and the majority of that time suffering from symptoms of depression, which complicates the accurate diagnosis of bipolar disorder. Challenges in the differential diagnosis of bipolar disorder and major depressive disorder are reviewed, and the clinical utility of several screening instruments is evaluated. The estimated lifetime prevalence of major depressive disorder (i.e., unipolar depression) is over 3 and one-half times that of bipolar spectrum disorders. The clinical presentation of a major depressive episode in a bipolar disorder patient does not differ substantially from that of a patient with major depressive disorder (unipolar depression). Therefore, it is not surprising that without proper screening and comprehensive evaluation many patients with bipolar disorder may be misdiagnosed with major depressive disorder (unipolar depression). In general, antidepressants have demonstrated little or no efficacy for depressive episodes associated with bipolar disorder, and treatment guidelines recommend using antidepressants only as an adjunct to mood stabilizers for patients with bipolar disorder. Thus, correct identification of bipolar disorder among patients who present with depression is critical for providing appropriate treatment and improving patient outcomes. Clinical characteristics indicative of bipolar disorder versus major depressive disorder identified in this review are based on group differences and may not apply to each individual patient. The overview of demographic and clinical characteristics provided by this review may help medical professionals distinguish between major depressive disorder and bipolar disorder. Several validated, easily administered screening instruments are available and can greatly improve the recognition of bipolar disorder in patients with depression. Copyright © 2014 Elsevier B.V. All rights reserved.

  5. Regulation of glycogen synthase kinase-3 during bipolar mania treatment.

    Science.gov (United States)

    Li, Xiaohong; Liu, Min; Cai, Zhuoji; Wang, Gang; Li, Xiaohua

    2010-11-01

    Bipolar disorder is a debilitating psychiatric illness presenting with recurrent mania and depression. The pathophysiology of bipolar disorder is poorly understood, and molecular targets in the treatment of bipolar disorder remain to be identified. Preclinical studies have suggested that glycogen synthase kinase-3 (GSK3) is a potential therapeutic target in bipolar disorder, but evidence of abnormal GSK3 in human bipolar disorder and its response to treatment is still lacking. This study was conducted in acutely ill type I bipolar disorder subjects who were hospitalized for a manic episode. The protein level and the inhibitory serine phosphorylation of GSK3 in peripheral blood mononuclear cells of bipolar manic and healthy control subjects were compared, and the response of GSK3 to antimanic treatment was evaluated. The levels of GSK3α and GSK3β in this group of bipolar manic subjects were higher than healthy controls. Symptom improvement during an eight-week antimanic treatment with lithium, valproate, and atypical antipsychotics was accompanied by a significant increase in the inhibitory serine phosphorylation of GSK3, but not the total level of GSK3, whereas concomitant electroconvulsive therapy treatment during a manic episode appeared to dampen the response of GSK3 to pharmacological treatment. Results of this study suggest that GSK3 can be modified during the treatment of bipolar mania. This finding in human bipolar disorder is in agreement with preclinical data suggesting that inhibition of GSK3 by increasing serine phosphorylation is a response of GSK3 to psychotropics used in bipolar disorder, supporting the notion that GSK3 is a promising molecular target in the pharmacological treatment of bipolar disorder. © 2010 John Wiley and Sons A/S.

  6. Nonlinear System Analysis in Bipolar Integrated Circuits.

    Science.gov (United States)

    1980-01-01

    H2 (fl,f 6), H2 (f2,f4), and H2 (f3,f4) are all equal, Equation (7-8) can be written as v M(t) = mA2 H2 (fl’-f 2) cos[27(f ,-f2)t] (7-9) The AF...and R. A. AMADORI: Micro- wave Interference Effect in Bipolar Transistors, IEEE Trans. EMC, Vol. EMC-17, pp. 216-219, November 1975. 55. KAPLAN , G

  7. Thought Suppression in Patients With Bipolar Disorder

    OpenAIRE

    Miklowitz, David J.; Alatiq, Yousra; Geddes, John R.; Goodwin, Guy M.; Williams, J. Mark G.

    2010-01-01

    Suppression of negative thoughts has been observed under experimental conditions among patients with major depressive disorder (MDD) but has never been examined among patients with bipolar disorder (BD). Patients with BD (n = 36), patients with MDD (n = 20), and healthy controls (n = 20) completed a task that required unscrambling 6-word strings into 5-word sentences, leaving out 1 word. The extra word allowed the sentences to be completed in a negative, neutral, or ?hyperpositive? (manic/goa...

  8. The Boomerang Nebula: a highly polarized bipolar

    International Nuclear Information System (INIS)

    Taylor, K.N.R.; Scarrott, S.M.

    1980-01-01

    An optical linear polarization map of a bipolar nebula is presented. Polarizations of approximately 60 per cent are observed in the optically thin lobes. The map leads to a geometry of the object consisting of a central star with an equatorial disc of dust and optically thin lobes illuminated by the central star. The grains in the disc are aligned. The object is a protoplanetary nebula. (author)

  9. Bipolar nickel-hydrogen battery development

    Science.gov (United States)

    Koehler, C. W.; Applewhite, A. Z.; Hall, A. M.; Russell, P. G.

    1985-01-01

    A comparison of the bipolar Ni-H2 battery with other energy systems to be used in future high-power space systems is presented. The initial design for the battery under the NASA-sponsored program is described and the candidate stack components are evaluated, including electrodes, separator, electrolyte reservoir plate, and recombination sites. The compressibility of the cell elements, electrolyte activation, and thermal design are discussed. Manufacturing and prototype test results are summarized.

  10. Smartphone based treatment in bipolar disorder

    DEFF Research Database (Denmark)

    Faurholt-Jepsen, M; Frost, M.; Bardram, J.E.

    2016-01-01

    During this symposium, results from a randomized controlled trial investigating the effect of smartphone based electronic self-monitoring on the severity of depressive and manic symptoms will be presented and discussed.Further, we will present and discuss the use of automatically generated...... objective smartphone data on behavioral activities (eg social activities, mobility and physical activity) as electronic biomarkers of illness activity in bipolar disorder....

  11. Pituitary gland volumes in bipolar disorder.

    Science.gov (United States)

    Clark, Ian A; Mackay, Clare E; Goodwin, Guy M

    2014-12-01

    Bipolar disorder has been associated with increased Hypothalamic-Pituitary-Adrenal axis function. The mechanism is not well understood, but there may be associated increases in pituitary gland volume (PGV) and these small increases may be functionally significant. However, research investigating PGV in bipolar disorder reports mixed results. The aim of the current study was twofold. First, to assess PGV in two novel samples of patients with bipolar disorder and matched healthy controls. Second, to perform a meta-analysis comparing PGV across a larger sample of patients and matched controls. Sample 1 consisted of 23 established patients and 32 matched controls. Sample 2 consisted of 39 medication-naïve patients and 42 matched controls. PGV was measured on structural MRI scans. Seven further studies were identified comparing PGV between patients and matched controls (total n; 244 patients, 308 controls). Both novel samples showed a small (approximately 20mm(3) or 4%), but non-significant, increase in PGV in patients. Combining the two novel samples showed a significant association of age and PGV. Meta-analysis showed a trend towards a larger pituitary gland in patients (effect size: .23, CI: -.14, .59). While results suggest a possible small difference in pituitary gland volume between patients and matched controls, larger mega-analyses with sample sizes greater even than those used in the current meta-analysis are still required. There is a small but potentially functionally significant increase in PGV in patients with bipolar disorder compared to controls. Results demonstrate the difficulty of finding potentially important but small effects in functional brain disorders. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. Bipolar disorder, a precursor of Parkinson's disease?

    Directory of Open Access Journals (Sweden)

    Tânia M.S. Novaretti

    Full Text Available ABSTRACT Parkinson's disease is a neurodegenerative disorder predominantly resulting from dopamine depletion in the substantia nigra pars compacta. Some psychiatric disorders may have dopaminergic dysfunction as their substrate. We describe a well-documented case of Parkinson's disease associated with Bipolar Disorder. Although there is some knowledge about the association between these diseases, little is known about its pathophysiology and correlation. We believe that among various hypotheses, many neurotransmitters are linked to this pathophysiology.

  13. Implantable liquid metal-based flexible neural microelectrode array and its application in recovering animal locomotion functions

    Science.gov (United States)

    Guo, Rui; Liu, Jing

    2017-10-01

    With significant advantages in rapidly restoring the nerve function, electrical stimulation of nervous tissue is a crucial treatment of peripheral nerve injuries leading to common movement disorder. However, the currently available stimulating electrodes generally based on rigid conductive materials would cause a potential mechanical mismatch with soft neural tissues which thus reduces long-term effects of electrical stimulation. Here, we proposed and fabricated a flexible neural microelectrode array system based on the liquid metal GaIn alloy (75.5% Ga and 24.5% In by weight) and via printing approach. Such an alloy with a unique low melting point (10.35 °C) owns excellent electrical conductivity and high compliance, which are beneficial to serve as implantable flexible neural electrodes. The flexible neural microelectrode array embeds four liquid metal electrodes and stretchable interconnects in a PDMS membrane (500 µm in thickness) that possess a lower elastic modulus (1.055 MPa), which is similar to neural tissues with elastic moduli in the 0.1-1.5 MPa range. The electrical experiments indicate that the liquid metal interconnects could sustain over 7000 mechanical stretch cycles with resistance approximately staying at 4 Ω. Over the conceptual experiments on animal sciatic nerve electrical stimulation, the dead bullfrog implanted with flexible neural microelectrode array could even rhythmically contract and move its lower limbs under the electrical stimulations from the implant. This demonstrates a highly efficient way for quickly recovering biological nerve functions. Further, the good biocompatibility of the liquid metal material was justified via a series of biological experiments. This liquid metal modality for neural stimulation is expected to play important roles as biologic electrodes to overcome the fundamental mismatch in mechanics between biological tissues and electronic devices in the coming time.

  14. Implantable liquid metal-based flexible neural microelectrode array and its application in recovering animal locomotion functions

    International Nuclear Information System (INIS)

    Guo, Rui; Liu, Jing

    2017-01-01

    With significant advantages in rapidly restoring the nerve function, electrical stimulation of nervous tissue is a crucial treatment of peripheral nerve injuries leading to common movement disorder. However, the currently available stimulating electrodes generally based on rigid conductive materials would cause a potential mechanical mismatch with soft neural tissues which thus reduces long-term effects of electrical stimulation. Here, we proposed and fabricated a flexible neural microelectrode array system based on the liquid metal GaIn alloy (75.5% Ga and 24.5% In by weight) and via printing approach. Such an alloy with a unique low melting point (10.35 °C) owns excellent electrical conductivity and high compliance, which are beneficial to serve as implantable flexible neural electrodes. The flexible neural microelectrode array embeds four liquid metal electrodes and stretchable interconnects in a PDMS membrane (500 µ m in thickness) that possess a lower elastic modulus (1.055 MPa), which is similar to neural tissues with elastic moduli in the 0.1–1.5 MPa range. The electrical experiments indicate that the liquid metal interconnects could sustain over 7000 mechanical stretch cycles with resistance approximately staying at 4 Ω. Over the conceptual experiments on animal sciatic nerve electrical stimulation, the dead bullfrog implanted with flexible neural microelectrode array could even rhythmically contract and move its lower limbs under the electrical stimulations from the implant. This demonstrates a highly efficient way for quickly recovering biological nerve functions. Further, the good biocompatibility of the liquid metal material was justified via a series of biological experiments. This liquid metal modality for neural stimulation is expected to play important roles as biologic electrodes to overcome the fundamental mismatch in mechanics between biological tissues and electronic devices in the coming time. (paper)

  15. Recurrence and Relapse in Bipolar Mood Disorder

    Directory of Open Access Journals (Sweden)

    S Gh Mousavi

    2004-06-01

    Full Text Available Background: Despite the effectiveness of pharmacotherapy in acute phase of bipolar mood disorder, patients often experience relapses or recurrent episodes. Hospitalization of patients need a great deal of financial and humanistic resources which can be saved through understanding more about the rate of relapse and factors affecting this rate. Methods: In a descriptive analytical study, 380 patients with bipolar disorder who were hospitalized in psychiatric emergency ward of Noor hospital, Isfahan, Iran, were followed. Each patient was considered for; the frequency of relapse and recurrence, kind of pharmachotherapy, presence of psychotherapeutic treatments, frequency of visits by psychiatrist and the rank of present episode. Results: The overall prevalence of recurrence was 42.2%. Recurrence was lower in patients using lithium carbonate or sodium valproate or combined therapy (about 40%, compared to those using carbamazepine (80%. Recurrence was higher in patients treated with only pharmacotherapy (44.5% compared to those treated with both pharmacotherapy and psychotherapy (22.2%. Patients who were visited monthy by psychiatrist had lower rate of recurrence compared to those who had irregular visits. Conclusion: The higher rate of recurrence observed in carbamazepine therapy may be due to its adverse reactions and consequently poor compliance to this drug. Lower rates of recurrence with psychotherapy and regular visits may be related to the preventive effects of these procedures and especially to the effective management of stress. Keywords: Bipolar Mood Disorder, Recurrence, Relapse.

  16. Historical Underpinnings of Bipolar Disorder Diagnostic Criteria

    Directory of Open Access Journals (Sweden)

    Brittany L. Mason

    2016-07-01

    Full Text Available Mood is the changing expression of emotion and can be described as a spectrum. The outermost ends of this spectrum highlight two states, the lowest low, melancholia, and the highest high, mania. These mood extremes have been documented repeatedly in human history, being first systematically described by Hippocrates. Nineteenth century contemporaries Falret and Baillarger described two forms of an extreme mood disorder, with the validity and accuracy of both debated. Regardless, the concept of a cycling mood disease was accepted before the end of the 19th century. Kraepelin then described “manic depressive insanity” and presented his description of a full spectrum of mood dysfunction which could be exhibited through single episodes of mania or depression or a complement of many episodes of each. It was this concept which was incorporated into the first DSM and carried out until DSM-III, in which the description of episodic mood dysfunction was used to build a diagnosis of bipolar disorder. Criticism of this approach is explored through discussion of the bipolar spectrum concept and some recent examinations of the clinical validity of these DSM diagnoses are presented. The concept of bipolar disorder in children is also explored.

  17. Formation of Bipolar Lobes by Jets

    Science.gov (United States)

    Soker, Noam

    2002-04-01

    I conduct an analytical study of the interaction of jets, or a collimated fast wind (CFW), with a previously blown asymptotic giant branch (AGB) slow wind. Such jets (or CFWs) are supposedly formed when a compact companion, a main-sequence star, or a white dwarf accretes mass from the AGB star, forms an accretion disk, and blows two jets. This type of flow, which I think shapes bipolar planetary nebulae (PNs), requires three-dimensional gasdynamical simulations, which are limited in the parameter space they can cover. By imposing several simplifying assumptions, I derive simple expressions which reproduce some basic properties of lobes in bipolar PNs and which can be used to guide future numerical simulations. I quantitatively apply the results to two proto-PNs. I show that the jet interaction with the slow wind can form lobes which are narrow close to, and far away from, the central binary system, and which are wider somewhere in between. Jets that are recollimated and have constant cross section can form cylindrical lobes with constant diameter, as observed in several bipolar PNs. Close to their source, jets blown by main-sequence companions are radiative; only further out they become adiabatic, i.e., they form high-temperature, low-density bubbles that inflate the lobes.

  18. The electrolysis time on electrosynthesis of hydroxyapatite with bipolar membrane

    Science.gov (United States)

    Nur, Adrian; Jumari, Arif; Budiman, Anatta Wahyu; Puspitaningtyas, Stella Febianti; Cahyaningrum, Suci; Nazriati, Nazriati; Fajaroh, Fauziatul

    2018-02-01

    The electrochemical method with bipolar membrane has been successfully used for the synthesis of hydroxyapatite. In this work, we have developed 2 chambers electrolysis system separated by a bipolar membrane. The membrane was used to separate cations (H+ ions produced by the oxidation of water at the anode) and anions (OH- ions produced by the reduction of water at the cathode). With this system, we have designed that OH- ions still stay in the anions chamber because OH- ions was very substantial in the hydroxyapatite particles formation. The aim of this paper was to compare the electrolysis time on electrosynthesis of hydroxyapatite with and without the bipolar membrane. The electrosynthesis was performed at 500 mA/cm2 for 0.5 to 2 hours at room temperature and under ultrasonic cleaner to void agglomeration with and without the bipolar membrane. The electrosynthesis of hydroxyapatite with the bipolar membrane more effective than without the bipolar membrane. The hydroxyapatite has been appeared at 0.5 h of the electrolysis time with the bipolar membrane (at the cathode chamber) while it hasn't been seen without the bipolar membrane. The bipolar membrane prevents OH- ions migrate to the cation chamber. The formation of HA becomes more effective because OH- ions just formed HA particle.

  19. Suprasensory phenomena in those with a bipolar disorder.

    Science.gov (United States)

    Parker, Gordon; Paterson, Amelia; Romano, Mia; Granville Smith, Isabelle

    2018-03-01

    To increase awareness of the sensory changes experienced during hypo/manic and depressive states by those with a bipolar disorder and determine if the prevalence of such features is similar across differing bipolar sub-types. We interviewed 66 patients who acknowledged sensory changes during hypo/manic states. They were allocated to bipolar I, bipolar II and soft bipolar diagnostic categories and the prevalence of 10 differing sensory changes was quantified during hypo/manic and depressive phases. Bipolar I patients were just as likely, if not more likely, to report suprasensory changes which typically involved enhancement of senses during hypo/manic phases and muting or blunting during depressive phases. The high prevalence of changes in intuition, empathy, appreciation of danger and predictive capacities suggests that these are more part of the intrinsic bipolar mood domain states and not necessarily suprasensory, while changes in primary senses of smell, taste, vision, touch and hearing appear to more commonly define the suprasensory domain. It is important for clinicians and patients with a bipolar disorder to be aware of non-psychotic, suprasensory phenomena. Identification of such features may aid diagnosis and also explain the recognised increased creativity in those with a bipolar condition.

  20. Coping and personality in older patients with bipolar disorder.

    Science.gov (United States)

    Schouws, Sigfried N T M; Paans, Nadine P G; Comijs, Hannie C; Dols, Annemiek; Stek, Max L

    2015-09-15

    Little is known about coping styles and personality traits in older bipolar patients. Adult bipolar patients show a passive coping style and higher neuroticism scores compared to the general population. Our aim is to investigate personality traits and coping in older bipolar patients and the relationship between coping and personality. 75 Older patients (age > 60) with bipolar I or II disorder in a euthymic mood completed the Utrecht Coping List and the NEO Personality Inventory FFI and were compared to normative data. Older bipolar patients show more passive coping styles compared to healthy elderly. Their personality traits are predominated by openness, in contrast conscientiousness and altruism are relatively sparse. Neuroticism was related to passive coping styles, whereas conscientiousness was related to an active coping style. Older bipolar patients have more passive coping styles. Their personality is characterized by openness and relatively low conscientiousness and altruism. Our sample represents a survival cohort; this may explain the differences in personality traits between older patients in this study and in adult bipolar patients in other studies. The association between coping styles and personality traits is comparable to reports of younger adult patients with bipolar disorder. Longitudinal studies are warranted to explore if coping and personality change with ageing in bipolar patients and to determine which coping style is most effective in preventing mood episodes. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. Group interpersonal and social rhythm therapy for bipolar depression.

    Science.gov (United States)

    Hoberg, Astrid A; Ponto, Julie; Nelson, Pamela J; Frye, Mark A

    2013-10-01

    To evaluate the feasibility of 2-week interpersonal and social rhythm therapy group (IPSRT-G) for bipolar depression. Participants with bipolar depression received two individual sessions, six IPSRT-G sessions, and a 12-week telephone call. The Inventory of Depressive Symptomatology-Clinician Rated (IDS-C), Young Mania Rating Scale (YMRS), Sheehan Disability Scale (SDS), and Clinical Global Impressions-Bipolar Version (CGI-BP) were used. IDS-C and SDS scores improved significantly at 12 weeks. YMRS and CGI-BP scores improved but did not reach statistical significance. The promising antidepressive response supports further study of IPSRT-G for bipolar depression. © 2013 Wiley Periodicals, Inc.

  2. "Is it menopause or bipolar?": a qualitative study of the experience of menopause for women with bipolar disorder.

    Science.gov (United States)

    Perich, Tania; Ussher, Jane; Parton, Chloe

    2017-11-16

    Menopause can be a time of change for women and may be marked by disturbances in mood. For women living with a mental illness, such as bipolar disorder, little is known about how they experience mood changes during menopause. This study aimed to explore how women with bipolar disorder constructed mood changes during menopause and how this impacted on treatment decisions. Semi-structured interviews were undertaken with fifteen women who reported they had been diagnosed with bipolar disorder. Data was analysed using thematic analysis guided by a social constructionist framework. Themes identified included 'Constructions of mood change: menopause or bipolar disorder?',' Life events, bipolar disorder and menopause coming together'; 'Treatment choices for mood change during menopause'. The accounts suggested that women related to the experience of mood changes during menopause through the lens of their existing framework of bipolar disorder, with implications for understanding of self and treatment choices.

  3. Resistive and reactive changes to the impedance of intracortical microelectrodes can be mitigated with polyethylene glycol under acute in vitro and in vivo settings

    Directory of Open Access Journals (Sweden)

    Salah eSommakia

    2014-08-01

    Full Text Available The reactive response of brain tissue to implantable intracortical microelectrodes is thought to negatively affect their recordable signal quality and impedance, resulting in unreliable longitudinal performance. The relationship between the progression of the reactive tissue into a glial scar and the decline in device performance is unclear. We show that exposure to a model protein solution in vitro and acute implantation result in both resistive and capacitive changes to electrode impedance, rather than purely resistive changes. We also show that applying 4000 MW polyethylene glycol (PEG prevents impedance increases in vitro, and reduces the percent change in impedance in vivo following implantation. Our results highlight the importance of considering the contributions of non-cellular components to the decline in neural microelectrode performance, and present a proof of concept for using a simple dip-coated PEG film to modulate changes in microelectrode impedance.

  4. The bipolarity of light and dark: A review on Bipolar Disorder and circadian cycles.

    Science.gov (United States)

    Abreu, T; Bragança, M

    2015-10-01

    Bipolar Disorder is characterized by episodes running the full mood spectrum, from mania to depression. Between mood episodes, residual symptoms remain, as sleep alterations, circadian cycle disturbances, emotional deregulation, cognitive impairment and increased risk for comorbidities. The present review intends to reflect about the most recent and relevant information concerning the biunivocal relation between bipolar disorder and circadian cycles. It was conducted a literature search on PubMed database using the search terms "bipolar", "circadian", "melatonin", "cortisol", "body temperature", "Clock gene", "Bmal1 gene", "Per gene", "Cry gene", "GSK3β", "chronotype", "light therapy", "dark therapy", "sleep deprivation", "lithum" and "agomelatine". Search results were manually reviewed, and pertinent studies were selected for inclusion as appropriate. Several studies support the relationship between bipolar disorder and circadian cycles, discussing alterations in melatonin, body temperature and cortisol rhythms; disruption of sleep/wake cycle; variations of clock genes; and chronotype. Some therapeutics for bipolar disorder directed to the circadian cycles disturbances are also discussed, including lithium carbonate, agomelatine, light therapy, dark therapy, sleep deprivation and interpersonal and social rhythm therapy. This review provides a summary of an extensive research for the relevant literature on this theme, not a patient-wise meta-analysis. In the future, it is essential to achieve a better understanding of the relation between bipolar disorder and the circadian system. It is required to establish new treatment protocols, combining psychotherapy, therapies targeting the circadian rhythms and the latest drugs, in order to reduce the risk of relapse and improve affective behaviour. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. Cognitive vulnerability to bipolar disorder in offspring of parents with bipolar disorder.

    Science.gov (United States)

    Pavlickova, Hana; Turnbull, Oliver; Bentall, Richard P

    2014-11-01

    Bipolar disorder is a highly heritable illness, with a positive family history robustly predictive of its onset. It follows that studying biological children of parents with bipolar disorder may provide information about developmental pathways to the disorder. Moreover, such studies may serve as a useful test of theories that attribute a causal role in the development of mood disorders to psychological processes. Psychological style (including self-esteem, coping style with depression, domain-specific risk-taking, sensation-seeking, sensitivity to reward and punishment, and hypomanic personality and cognition) was assessed in 30 offspring of bipolar parents and 30 children of well parents. Parents of both child groups completed identical assessments. Although expected differences between parents with bipolar disorder and well parents were detected (such as low self-esteem, increased rumination, high sensitivity to reward and punishment), offspring of bipolar parents were, as a group, not significantly different from well offspring, apart from a modest trend towards lower adaptive coping. When divided into affected and non-affected subgroups, both groups of index children showed lower novelty-seeking. Only affected index children showed lower self-esteem, increased rumination, sensitivity to punishment, and hypomanic cognitions. Notably, these processes were associated with symptoms of depression. Psychological abnormalities in index offspring were associated with having met diagnostic criteria for psychiatric illnesses and the presence of mood symptoms, rather than preceding them. Implications of the present findings for our understanding of the development of bipolar disorder, as well as for informing early interventions, are discussed. © 2014 The British Psychological Society.

  6. Bipolar disorder and age-related functional impairment Prejuízo funcional associado à idade e transtorno bipolar

    Directory of Open Access Journals (Sweden)

    Alice Aita Cacilhas

    2009-12-01

    Full Text Available OBJECTIVE: Although bipolar disorder is a major contributor to functional impairment worldwide, an independent impact of bipolar disorder and ageing on functioning has yet to be demonstrated. The objective of the present study was to evaluate the effect of bipolar disorder on age-related functional status using matched controls as a standard. METHOD: One-hundred patients with bipolar disorder and matched controls were evaluated for disability. Age-related effects controlled for confounders were cross-sectionally evaluated. RESULTS: Patients were significantly more impaired than controls. Regression showed effects for aging in both groups. The effect, size, however, was significantly stronger in patients. CONCLUSION: Bipolar disorder was an important effect modifier of the age impact on functioning. While a longitudinal design is needed to effectively demonstrate this different impact, this study further depicts bipolar disorder as a chronic and progressively impairing illness.OBJETIVO: O transtorno bipolar é responsável por importante parcela do prejuízo funcional ao redor do mundo. Um efeito independente do transtorno bipolar e da idade no funcionamento ainda não foi demonstrado. O presente estudo tem o objetivo de avaliar o efeito do transtorno bipolar no prejuízo funcional relacionado à idade, com controles pareados como padrão. MÉTODO: Cem pacientes com transtorno bipolar e controles pareados foram avaliados para incapacidade. Efeitos relacionados à idade, com controle para confundidores, foram investigados. RESULTADOS: Pacientes tiveram significativamente mais prejuízo que controles. A regressão mostrou efeito para a idade em ambos os grupos, e o efeito foi significativamente mais forte nos pacientes. CONCLUSÃO: O transtorno bipolar foi um importante modificador de efeito no impacto da idade no funcionamento. Enquanto um desenho de estudo longitudinal é necessário para efetivamente demonstrar este impacto diferencial, este

  7. Bipolar polygenic loading and bipolar spectrum features in major depressive disorder

    Science.gov (United States)

    Wiste, Anna; Robinson, Elise B; Milaneschi, Yuri; Meier, Sandra; Ripke, Stephan; Clements, Caitlin C; Fitzmaurice, Garrett M; Rietschel, Marcella; Penninx, Brenda W; Smoller, Jordan W; Perlis, Roy H

    2014-01-01

    Objectives Family and genetic studies indicate overlapping liability for major depressive disorder and bipolar disorder. The purpose of this study was to determine whether this shared genetic liability influences clinical presentation. Methods A polygenic risk score for bipolar disorder, derived from a large genome-wide association meta-analysis, was generated for each subject of European–American ancestry (n = 1,274) in the Sequential Treatment Alternatives to Relieve Depression study (STAR*D) outpatient major depressive disorder cohort. A hypothesis-driven approach was used to test for association between bipolar disorder risk score and features of depression associated with bipolar disorder in the literature. Follow-up analyses were performed in two additional cohorts. Results A generalized linear mixed model including seven features hypothesized to be associated with bipolar spectrum illness was significantly associated with bipolar polygenic risk score [F = 2.07, degrees of freedom (df) = 7, p = 0.04). Features included early onset, suicide attempt, recurrent depression, atypical depression, subclinical mania, subclinical psychosis, and severity. Post-hoc univariate analyses demonstrated that the major contributors to this omnibus association were onset of illness at age ≤ 18 years [odds ratio (OR) = 1.2, p = 0.003], history of suicide attempt (OR = 1.21, p = 0.03), and presence of at least one manic symptom (OR = 1.16, p = 0.02). The maximal variance in these traits explained by polygenic score ranged from 0.8–1.1%. However, analyses in two replication cohorts testing a five feature model did not support this association. Conclusions Bipolar genetic loading appeared to be associated with bipolar-like presentation in major depressive disorder in the primary analysis. However, results are at most inconclusive because of lack of replication. Replication efforts are challenged by different ascertainment and assessment strategies in the different cohorts

  8. Methodological recommendations for cognition trials in bipolar disorder by the International Society for Bipolar Disorders Targeting Cognition Task Force

    DEFF Research Database (Denmark)

    Miskowiak, K W; Burdick, K E; Martinez-Aran, A

    2017-01-01

    OBJECTIVES: To aid the development of treatment for cognitive impairment in bipolar disorder, the International Society for Bipolar Disorders (ISBD) convened a task force to create a consensus-based guidance paper for the methodology and design of cognition trials in bipolar disorder. METHODS...... of treatments to illness stage and using a multimodal approach. CONCLUSIONS: This ISBD task force guidance paper provides the first consensus-based recommendations for cognition trials in bipolar disorder. Adherence to these recommendations will likely improve the sensitivity in detecting treatment efficacy...

  9. Six years of evidence-based adult dissection tonsillectomy with ultrasonic scalpel, bipolar electrocautery, bipolar radiofrequency or 'cold steel' dissection.

    Science.gov (United States)

    Ragab, S M

    2012-10-01

    To conduct an adequately powered, prospective, randomised, controlled trial comparing adult dissection tonsillectomy using either ultrasonic scalpel, bipolar electrocautery, bipolar radiofrequency or 'cold steel' dissection. Three hundred patients were randomised into four tonsillectomy technique groups. The operative time, intra-operative bleeding, post-operative pain, tonsillar fossa healing, return to full diet, return to work and post-operative complications were recorded. The bipolar radiofrequency group had a shorter mean operative time. The mean intra-operative blood loss during bipolar radiofrequency tonsillectomy was significantly less compared with cold dissection and ultrasonic scalpel tonsillectomy. Pain scores were significantly higher after bipolar electrocautery tonsillectomy. Patients undergoing bipolar electrocautery tonsillectomy required significantly more days to return to full diet and work. The bipolar electrocautery group showed significantly reduced tonsillar fossa healing during the first and second post-operative weeks. In this adult series, bipolar radiofrequency tonsillectomy was superior to ultrasonic, bipolar electrocautery and cold dissection tonsillectomies. This method combines the advantages of 'hot' and 'cold' tonsillectomy.

  10. Is impulsivity a common trait in bipolar and unipolar disorders?

    Science.gov (United States)

    Henna, Elaine; Hatch, John P; Nicoletti, Mark; Swann, Alan C; Zunta-Soares, Giovana; Soares, Jair C

    2013-03-01

      Impulsivity is increased in bipolar and unipolar disorders during episodes and is associated with substance abuse disorders and suicide risk. Impulsivity between episodes predisposes to relapses and poor therapeutic compliance. However, there is little information about impulsivity during euthymia in mood disorders. We sought to investigate trait impulsivity in euthymic bipolar and unipolar disorder patients, comparing them to healthy individuals and unaffected relatives of bipolar disorder patients.   Impulsivity was evaluated by the Barratt Impulsiveness Scale (BIS-11A) in 54 bipolar disorder patients, 25 unipolar disorder patients, 136 healthy volunteers, and 14 unaffected relatives. The BIS-11A mean scores for all four groups were compared through the Games-Howell test for all possible pairwise combinations. Additionally, we compared impulsivity in bipolar and unipolar disorder patients with and without a history of suicide attempt and substance abuse disorder.   Bipolar and unipolar disorder patients scored significantly higher than the healthy controls and unaffected relatives on all measures of the BIS-11A except for attentional impulsivity. On the attentional impulsivity measures there were no differences among the unaffected relatives and the bipolar and unipolar disorder groups, but all three of these groups scored higher than the healthy participant group. There was no difference in impulsivity between bipolar and unipolar disorder subjects with and without suicide attempt. However, impulsivity was higher among bipolar and unipolar disorder subjects with past substance use disorder compared to patients without such a history.   Questionnaire-measured impulsivity appears to be relatively independent of mood state in bipolar and unipolar disorder patients; it remains elevated in euthymia and is higher in individuals with past substance abuse. Elevated attentional and lower non-planning impulsivity in unaffected relatives of bipolar disorder

  11. Importance of Thickness in Human Cardiomyocyte Network for Effective Electrophysiological Stimulation Using On-Chip Extracellular Microelectrodes

    Science.gov (United States)

    Hamada, Tomoyo; Nomura, Fumimasa; Kaneko, Tomoyuki; Yasuda, Kenji

    2012-06-01

    We have developed a three-dimensionally controlled in vitro human cardiomyocyte network assay for the measurements of drug-induced conductivity changes and the appearance of fatal arrhythmia such as ventricular tachycardia/fibrillation for more precise in vitro predictive cardiotoxicity. To construct an artificial conductance propagation model of a human cardiomyocyte network, first, we examined the cell concentration dependence of the cell network heights and found the existence of a height limit of cell networks, which was double-layer height, whereas the cardiomyocytes were effectively and homogeneously cultivated within the microchamber maintaining their spatial distribution constant and their electrophysiological conductance and propagation were successfully recorded using a microelectrode array set on the bottom of the microchamber. The pacing ability of a cardiomyocyte's electrophysiological response has been evaluated using microelectrode extracellular stimulation, and the stimulation for pacing also successfully regulated the beating frequencies of two-layered cardiomyocyte networks, whereas monolayered cardiomyocyte networks were hardly stimulated by the external electrodes using the two-layered cardiomyocyte stimulation condition. The stability of the lined-up shape of human cardiomyocytes within the rectangularly arranged agarose microchambers was limited for a two-layered cardiomyocyte network because their stronger force generation shrunk those cells after peeling off the substrate. The results indicate the importance of fabrication technology of thickness control of cellular networks for effective extracellular stimulation and the potential concerning thick cardiomyocyte networks for long-term cultivation.

  12. A feasibility study of multi-site,intracellular recordings from mammalian neurons by extracellular gold mushroom-shaped microelectrodes.

    Science.gov (United States)

    Ojovan, Silviya M; Rabieh, Noha; Shmoel, Nava; Erez, Hadas; Maydan, Eilon; Cohen, Ariel; Spira, Micha E

    2015-09-14

    The development of multi-electrode array platforms for large scale recording of neurons is at the forefront of neuro-engineering research efforts. Recently we demonstrated, at the proof-of-concept level, a breakthrough neuron-microelectrode interface in which cultured Aplysia neurons tightly engulf gold mushroom-shaped microelectrodes (gMμEs). While maintaining their extracellular position, the gMμEs record synaptic- and action-potentials with characteristic features of intracellular recordings. Here we examined the feasibility of using gMμEs for intracellular recordings from mammalian neurons. To that end we experimentally examined the innate size limits of cultured rat hippocampal neurons to engulf gMμEs and measured the width of the "extracellular" cleft formed between the neurons and the gold surface. Using the experimental results we next analyzed the expected range of gMμEs-neuron electrical coupling coefficients. We estimated that sufficient electrical coupling levels to record attenuated synaptic- and action-potentials can be reached using the gMμE-neuron configuration. The definition of the engulfment limits of the gMμEs caps diameter at ≤2-2.5 μm and the estimated electrical coupling coefficients from the simulations pave the way for rational development and application of the gMμE based concept for in-cell recordings from mammalian neurons.

  13. In situ 2D maps of pH shifts across brass–lead galvanic joints using microelectrodes

    International Nuclear Information System (INIS)

    Ma, Xiangmeng; Lee, Woo Hyoung; Lytle, Darren A

    2017-01-01

    Galvanic corrosion in drinking water distribution systems, such as conditions following partial lead service line replacement, can be a significant source of lead in tap water. The objective of this work was to measure the pH directly near metal surfaces using a novel experimental tool in order to understand the water chemistry at a lead-containing galvanic couple in drinking water. Specifically, pH microprofiles in the proximity of corroding metal surfaces were measured using a microelectrode to construct detailed in situ 2D spatial maps of the pH across a galvanic couple at 100 µ m above the metal’s surface under flowing and stagnation conditions. The opposite pH trend was directly observed across the galvanic couple under flow and stagnation conditions. Water stagnation resulted in a pH at the anode (leaded solder) of 1.5 pH units lower than the bulk water pH (9.0) and as much as 2.5 pH units lower than the cathode (brass). These conditions can enhance lead release at the anode, which reflects different anodic–cathodic relationships of coupled metals primarily controlled by water flow. Most importantly, this work has demonstrated the ability to make real pH measurement at the surface of corroding metals using a novel microelectrode approach. (paper)

  14. Compact microelectrode array system: tool for in situ monitoring of drug effects on neurotransmitter release from neural cells.

    Science.gov (United States)

    Chen, Yu; Guo, Chunxian; Lim, Layhar; Cheong, Serchoong; Zhang, Qingxin; Tang, Kumcheong; Reboud, Julien

    2008-02-15

    This paper presents a compact microelectrode array (MEA) system, to study potassium ion-induced dopamine release from PC12 neural cells, without relying on a micromanipulator and a microscope. The MEA chip was integrated with a custom-made "test jig", which provides a robust electrical interfacing tool between the microchip and the macroenvironment, together with a potentiostat and a microfluidic syringe pump. This integrated system significantly simplifies the operation procedures, enhances sensing performance, and reduces fabrication costs. The achieved detection limit for dopamine is 3.8 x 10-2 muM (signal/noise, S/N = 3) and the dopamine linear calibration range is up to 7.39 +/- 0.06 muM (mean +/- SE). The effects of the extracelluar matrix collagen coating of the microelectrodes on dopamine sensing behaviors, as well as the influences of K+ and l-3,4-digydroxyphenylalanine concentrations and incubation times on dopamine release, were extensively studied. The results show that our system is well suited for biologists to study chemical release from living cells as well as drug effects on secreting cells. The current system also shows a potential for further improvements toward a multichip array system for drug screening applications.

  15. Creation of defined single cell resolution neuronal circuits on microelectrode arrays

    Science.gov (United States)

    Pirlo, Russell Kirk

    2009-12-01

    The way cell-cell organization of neuronal networks influences activity and facilitates function is not well understood. Microelectrode arrays (MEAs) and advancing cell patterning technologies have enabled access to and control of in vitro neuronal networks spawning much new research in neuroscience and neuroengineering. We propose that small, simple networks of neurons with defined circuitry may serve as valuable research models where every connection can be analyzed, controlled and manipulated. Towards the goal of creating such neuronal networks we have applied microfabricated elastomeric membranes, surface modification and our unique laser cell patterning system to create defined neuronal circuits with single-cell precision on MEAs. Definition of synaptic connectivity was imposed by the 3D physical constraints of polydimethylsiloxane elastomeric membranes. The membranes had 20mum clear-through holes and 2-3mum deep channels which when applied to the surface of the MEA formed microwells to confine neurons to electrodes connected via shallow tunnels to direct neurite outgrowth. Tapering and turning of channels was used to influence neurite polarity. Biocompatibility of the membranes was increased by vacuum baking, oligomer extraction, and autoclaving. Membranes were bound to the MEA by oxygen plasma treatment and heated pressure. The MEA/membrane surface was treated with oxygen plasma, poly-D-lysine and laminin to improve neuron attachment, survival and neurite outgrowth. Prior to cell patterning the outer edge of culture area was seeded with 5x10 5 cells per cm and incubated for 2 days. Single embryonic day 7 chick forebrain neurons were then patterned into the microwells and onto the electrodes using our laser cell patterning system. Patterned neurons successfully attached to and were confined to the electrodes. Neurites extended through the interconnecting channels and connected with adjacent neurons. These results demonstrate that neuronal circuits can be

  16. Neurotoxicity screening of (illicit) drugs using novel methods for analysis of microelectrode array (MEA) recordings.

    Science.gov (United States)

    Hondebrink, L; Verboven, A H A; Drega, W S; Schmeink, S; de Groot, M W G D M; van Kleef, R G D M; Wijnolts, F M J; de Groot, A; Meulenbelt, J; Westerink, R H S

    2016-07-01

    Annual prevalence of the use of common illicit drugs and new psychoactive substances (NPS) is high, despite the often limited knowledge on the health risks of these substances. Recently, cortical cultures grown on multi-well microelectrode arrays (mwMEAs) have been used for neurotoxicity screening of chemicals, pharmaceuticals, and toxins with a high sensitivity and specificity. However, the use of mwMEAs to investigate the effects of illicit drugs on neuronal activity is largely unexplored. We therefore first characterised the cortical cultures using immunocytochemistry and show the presence of astrocytes, glutamatergic and GABAergic neurons. Neuronal activity is concentration-dependently affected following exposure to six neurotransmitters (glutamate, GABA, serotonin, dopamine, acetylcholine and nicotine). Most neurotransmitters inhibit neuronal activity, although glutamate and acetylcholine transiently increase activity at specific concentrations. These transient effects are not detected when activity is determined during the entire 30min exposure window, potentially resulting in false-negative results. As expected, exposure to the GABAA-receptor antagonist bicuculline increases neuronal activity. Exposure to a positive allosteric modulator of the GABAA-receptor (diazepam) or to glutamate receptor antagonists (CNQX and MK-801) reduces neuronal activity. Further, we demonstrate that exposure to common drugs (3,4-methylenedioxymethamphetamine (MDMA) and amphetamine) and NPS (1-(3-chlorophenyl)piperazine (mCPP), 4-fluoroamphetamine (4-FA) and methoxetamine (MXE)) decreases neuronal activity. MXE most potently inhibits neuronal activity with an IC50 of 0.5μM, whereas 4-FA is least potent with an IC50 of 113μM. Our data demonstrate the importance of analysing neuronal activity within different time windows during exposure to prevent false-negative results. We also show that cortical cultures grown on mwMEAs can successfully be applied to investigate the effects of

  17. Scanning electron microscopy of chronically implanted intracortical microelectrode arrays in non-human primates

    Science.gov (United States)

    Barrese, James C.; Aceros, Juan; Donoghue, John P.

    2016-04-01

    Objective. Signal attenuation is a major problem facing intracortical sensors for chronic neuroprosthetic applications. Many studies suggest that failure is due to gliosis around the electrode tips, however, mechanical and material causes of failure are often overlooked. The purpose of this study was to investigate the factors contributing to progressive signal decline by using scanning electron microscopy (SEM) to visualize structural changes in chronically implanted arrays and histology to examine the tissue response at corresponding implant sites. Approach. We examined eight chronically implanted intracortical microelectrode arrays (MEAs) explanted from non-human primates at times ranging from 37 to 1051 days post-implant. We used SEM, in vivo neural recordings, and histology (GFAP, Iba-1, NeuN). Three MEAs that were never implanted were also imaged as controls. Main results. SEM revealed progressive corrosion of the platinum electrode tips and changes to the underlying silicon. The parylene insulation was prone to cracking and delamination, and in some instances the silicone elastomer also delaminated from the edges of the MEA. Substantial tissue encapsulation was observed and was often seen growing into defects in the platinum and parylene. These material defects became more common as the time in vivo increased. Histology at 37 and 1051 days post-implant showed gliosis, disruption of normal cortical architecture with minimal neuronal loss, and high Iba-1 reactivity, especially within the arachnoid and dura. Electrode tracts were either absent or barely visible in the cortex at 1051 days, but were seen in the fibrotic encapsulation material suggesting that the MEAs were lifted out of the brain. Neural recordings showed a progressive drop in impedance, signal amplitude, and viable channels over time. Significance. These results provide evidence that signal loss in MEAs is truly multifactorial. Gliosis occurs in the first few months after implantation but does

  18. The bipolar puzzle, adding new pieces. Factors associated with bipolar disorder, Genetic and environmental influences

    NARCIS (Netherlands)

    van der Schot, A.C.

    2009-01-01

    The focus of this thesis is twofold. The first part will discuss the structural brain abnormalities and schoolperformance associated with bipolar disorder and the influence of genetic and/or environmental factors to this association. It is part of a large twin study investigating several potential

  19. [Bipolar disorders and anorexia nervosa: A clinical study].

    Science.gov (United States)

    Valentin, M; Radon, L; Duclos, J; Curt, F; Godart, N

    2018-06-20

    Anorexia nervosa is often accompanied by comorbid mood disorders, in particular depression, but individual or family history of bipolar disorders has not frequently been explored in anorexia nervosa. The objectives of the present study were: (1) to assess the frequency of bipolar disorders in patients with anorexia nervosa hospitalized in adolescence and in their parents, (2) to determine whether the patients with a personal or family history of bipolar disorders present particular characteristics in the way in which anorexia nervosa manifests itself, in their medical history, in the secondary diagnoses established, and in the treatments prescribed. Overall, 97 female patients aged 13 to 20 hospitalized for anorexia nervosa and their parents were assessed. The diagnoses of anorexia nervosa and bipolar disorders were established on the basis of DSM-IV-TR criteria. A high frequency of type II and type V bipolar disorders was observed. The patients with anorexia nervosa and presenting personal or family histories of bipolar disorder had an earlier onset of anorexia nervosa, more numerous hospitalizations, a longer time-lapse between anorexia nervosa onset and hospitalization, more suicide attempts and more psychiatric comorbidities. The occurrence of anorexia nervosa-bipolar disorders comorbidity appears to be considerable and linked to the severity of anorexia nervosa, raising the issue of the relationship between anorexia nervosa and bipolar disorders. Copyright © 2017. Published by Elsevier Masson SAS.

  20. Treatment outcomes of acute bipolar depressive episode with psychosis.

    Science.gov (United States)

    Caldieraro, Marco Antonio; Dufour, Steven; Sylvia, Louisa G; Gao, Keming; Ketter, Terence A; Bobo, William V; Walsh, Samantha; Janos, Jessica; Tohen, Mauricio; Reilly-Harrington, Noreen A; McElroy, Susan L; Shelton, Richard C; Bowden, Charles L; Deckersbach, Thilo; Nierenberg, Andrew A

    2018-05-01

    The impact of psychosis on the treatment of bipolar depression is remarkably understudied. The primary aim of this study was to compare treatment outcomes of bipolar depressed individuals with and without psychosis. The secondary aim was to compare the effect of lithium and quetiapine, each with adjunctive personalized treatments (APTs), in the psychotic subgroup. We assessed participants with DSM-IV bipolar depression included in a comparative effectiveness study of lithium and quetiapine with APTs (the Bipolar CHOICE study). Severity was assessed by the Bipolar Inventory of Symptoms Scale (BISS) and by the Clinical Global Impression Scale-Severity-Bipolar Version (CGI-S-BP). Mixed models were used to assess the course of symptom change, and Cox regression survival analysis was used to assess the time to remission. Psychotic features were present in 10.6% (n = 32) of the depressed participants (n = 303). Those with psychotic features had higher scores on the BISS before (75.2 ± 17.6 vs. 54.9 ± 16.3; P Bipolar depressive episodes with psychotic features are more severe, and compared to nonpsychotic depressions, present a similar course of improvement. Given the small number of participants presenting psychosis, the lack of statistically significant difference between lithium- and quetiapine-based treatment of psychotic bipolar depressive episodes needs replication in a larger sample. © 2018 Wiley Periodicals, Inc.

  1. The CBCL Bipolar Profile and Attention, Mood, and Behavior Dysregulation

    Science.gov (United States)

    Doerfler, Leonard A.; Connor, Daniel F.; Toscano, Peter F.

    2011-01-01

    Biederman and colleagues reported that a CBCL profile identified youngsters who were diagnosed with bipolar disorder. Some studies found that this CBCL profile does not reliably identify children who present with bipolar disorder, but nonetheless this CBCL does identify youngsters with severe dysfunction. However, the nature of the impairment of…

  2. Family environment patterns in families with bipolar children.

    Science.gov (United States)

    Belardinelli, Cecilia; Hatch, John P; Olvera, Rene L; Fonseca, Manoela; Caetano, Sheila C; Nicoletti, Mark; Pliszka, Steven; Soares, Jair C

    2008-04-01

    We studied the characteristics of family functioning in bipolar children and healthy comparison children. We hypothesized that the family environment of bipolar children would show greater levels of dysfunction as measured by the Family Environment Scale (FES). We compared the family functioning of 36 families that included a child with DSM-IV bipolar disorder versus 29 comparison families that included only healthy children. All subjects and their parents were assessed with the K-SADS-PL interview. The parents completed the FES to assess their current family functioning. Multivariate analysis of variance was used to compare the family environment of families with and without offspring with bipolar disorder. Parents of bipolar children reported lower levels of family cohesion (pfamilies where a parent had a history of mood disorders compared to families where parents had no history of mood disorders. Length of illness in the affected child was inversely associated with family cohesion (r=-0.47, p=0.004). Due to the case-control design of the study, we cannot comment on the development of these family problems or attribute their cause specifically to child bipolar disorder. Families with bipolar children show dysfunctional patterns related to interpersonal interactions and personal growth. A distressed family environment should be addressed when treating children with bipolar disorder.

  3. People-Things and Data-Ideas: Bipolar Dimensions?

    Science.gov (United States)

    Tay, Louis; Su, Rong; Rounds, James

    2011-01-01

    We examined a longstanding assumption in vocational psychology that people-things and data-ideas are bipolar dimensions. Two minimal criteria for bipolarity were proposed and examined across 3 studies: (a) The correlation between opposite interest types should be negative; (b) after correcting for systematic responding, the correlation should be…

  4. Bipolar Disorder: not only in the Brain - immunological aspects

    NARCIS (Netherlands)

    E.M. Knijff (Esther)

    2006-01-01

    textabstractThe main objective of this thesis was to obtain more insight in the role of the immune system in the pathogenesis of bipolar disorder by investigating various aberrancies in the immune system of patients with bipolar disorder. In Chapter 1 some general concepts, important for the

  5. Pediatric Bipolar Disorder: Evidence for Prodromal States and Early Markers

    Science.gov (United States)

    Luby, Joan L.; Navsaria, Neha

    2010-01-01

    Background: Childhood bipolar disorder remains a controversial but increasingly diagnosed disorder that is associated with significant impairment, chronic course and treatment resistance. Therefore, the search for prodromes or early markers of risk for later childhood bipolar disorder may be of great importance for prevention and/or early…

  6. Olfactocentric Paralimbic Cortex Morphology in Adolescents with Bipolar Disorder

    Science.gov (United States)

    Wang, Fei; Kalmar, Jessica H.; Womer, Fay Y.; Edmiston, Erin E.; Chepenik, Lara G.; Chen, Rachel; Spencer, Linda; Blumberg, Hilary P.

    2011-01-01

    The olfactocentric paralimbic cortex plays a critical role in the regulation of emotional and neurovegetative functions that are disrupted in core features of bipolar disorder. Adolescence is thought to be a critical period in both the maturation of the olfactocentric paralimbic cortex and in the emergence of bipolar disorder pathology. Together,…

  7. Bipolar Disorder in Children: Implications for Speech-Language Pathologists

    Science.gov (United States)

    Quattlebaum, Patricia D.; Grier, Betsy C.; Klubnik, Cynthia

    2012-01-01

    In the United States, bipolar disorder is an increasingly common diagnosis in children, and these children can present with severe behavior problems and emotionality. Many studies have documented the frequent coexistence of behavior disorders and speech-language disorders. Like other children with behavior disorders, children with bipolar disorder…

  8. Precursors in adolescence of adult-onset bipolar disorder.

    Science.gov (United States)

    Hiyoshi, Ayako; Sabet, Julia A; Sjöqvist, Hugo; Melinder, Carren; Brummer, Robert J; Montgomery, Scott

    2017-08-15

    Although the estimated contribution of genetic factors is high in bipolar disorder, environmental factors may also play a role. This Swedish register-based cohort study of men examined if physical and psychological characteristics in late adolescence, including factors previously linked with bipolar disorder (body mass index, asthma and allergy), are associated with subsequent bipolar disorder in adulthood. Unipolar depression and anxiety are analysed as additional outcomes to identify bipolar disorder-specific associations. A total of 213,693 men born between 1952 and 1956, who participated in compulsory military conscription assessments in late adolescence were followed up to 2009, excluding men with any psychiatric diagnoses at baseline. Cox regression estimated risk of bipolar disorder, depression and anxiety in adulthood associated with body mass index, asthma, allergy, muscular strength stress resilience and cognitive function in adolescence. BMI, asthma and allergy were not associated with bipolar disorder. Higher grip strength, cognitive function and stress resilience were associated with a reduced risk of bipolar disorder and the other disease outcomes. The sample consisted only of men; even though the characteristics in adolescence pre-dated disease onset, they may have been the consequence of prodromal disease. Associations with body mass index and asthma found by previous studies may be consequences of bipolar disorder or its treatment rather than risk factors. Inverse associations with all the outcome diagnoses for stress resilience, muscular strength and cognitive function may reflect general risks for these psychiatric disorders or intermediary factors. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. The Enigma of Bipolar Disorder in Children and Adolescents

    Science.gov (United States)

    Hatchett, Gregory T.

    2009-01-01

    In the past decade, there has been a proliferation in the number of children and adolescents diagnosed with bipolar disorder. Except in rare cases, the young people who receive this diagnosis do not meet the strict diagnostic criteria for bipolar disorder I or II in the DSM-IV-TR. Many pediatric psychiatrists insist there are important development…

  10. Diagnosis, Epidemiology and Management of Mixed States in Bipolar Disorder.

    Science.gov (United States)

    Fagiolini, Andrea; Coluccia, Anna; Maina, Giuseppe; Forgione, Rocco N; Goracci, Arianna; Cuomo, Alessandro; Young, Allan H

    2015-09-01

    Approximately 40% of patients with bipolar disorder experience mixed episodes, defined as a manic state with depressive features, or manic symptoms in a patient with bipolar depression. Compared with bipolar patients without mixed features, patients with bipolar mixed states generally have more severe symptomatology, more lifetime episodes of illness, worse clinical outcomes and higher rates of comorbidities, and thus present a significant clinical challenge. Most clinical trials have investigated second-generation neuroleptic monotherapy, monotherapy with anticonvulsants or lithium, combination therapy, and electroconvulsive therapy (ECT). Neuroleptic drugs are often used alone or in combination with anticonvulsants or lithium for preventive treatment, and ECT is an effective treatment for mixed manic episodes in situations where medication fails or cannot be used. Common antidepressants have been shown to worsen mania symptoms during mixed episodes without necessarily improving depressive symptoms; thus, they are not recommended during mixed episodes. A greater understanding of pathophysiological processes in bipolar disorder is now required to provide a more accurate diagnosis and new personalised treatment approaches. Targeted, specific treatments developed through a greater understanding of bipolar disorder pathophysiology, capable of affecting the underlying disease processes, could well prove to be more effective, faster acting, and better tolerated than existing therapies, therefore providing better outcomes for individuals affected by bipolar disorder. Until such time as targeted agents are available, second-generation neuroleptics are emerging as the treatment of choice in the management of mixed states in bipolar disorder.

  11. Cognitive-Behavioral Therapy for Rapid Cycling Bipolar Disorder

    Science.gov (United States)

    Reilly-Harrington, Noreen A.; Knauz, Robert O.

    2005-01-01

    This article describes the application of cognitive-behavioral therapy (CBT) to the treatment of rapid cycling bipolar disorder. Between 10% and 24% of bipolar patients experience a rapid cycling course, with 4 or more mood episodes occurring per year. Characterized by nonresponse to standard mood-stabilizing medications, rapid cyclers are…

  12. Tiagabine in treatment refractory bipolar disorder : a clinical case series

    NARCIS (Netherlands)

    Suppes, T; Chisholm, KA; Dhavale, D; Frye, MA; Atshuler, LL; McElroy, SL; Keck, PE; Nolen, WA; Kupka, R; Denicoff, KD; Leverich, GS; Rush, AJ; Post, RM

    2002-01-01

    Objectives: Anticonvulsants have provided major treatment advances for patients with bipolar disorder. Many of these drugs, including several with proven efficacy in bipolar mania or depression, enhance the activity of the gamma-amino butyric acid (GABA) neurotransmitter system. A new

  13. The Dutch Bipolar Offspring Study : 12-Year Follow-Up

    NARCIS (Netherlands)

    Mesman, Esther; Nolen, Willem A.; Reichart, Catrien G.; Wals, Marjolein; Hillegers, Manon N. J.

    Objective: Offspring of bipolar parents have a genetically increased risk of developing mood disorders. In a longitudinal study, the authors followed a bipolar offspring cohort from adolescence into adulthood to determine the onset, prevalence, and early course of mood disorders and other

  14. The poor prognosis of childhood-onset bipolar disorder

    NARCIS (Netherlands)

    Leverich, Gabriele S.; Post, Robert M.; Keck, Paul E.; Altshuler, Lori L.; Frye, Mark A.; Kupka, Ralph W.; Nolen, Willem A.; Suppes, Trisha; McElroy, Susan L.; Grunze, Heinz; Denicoff, Kirk; Moravec, Maria K. M.; Luckenbaugh, David

    Objective We examined age of onset of bipolar disorder as a potential course-of-iflness modifier with the hypothesis that early onset will engender more severe illness. Study design A total of 480 carefully diagnosed adult outpatients with bipolar disorder (mean age, 42.5 +/- 11.6 years) were

  15. Risk Factors of Attempted Suicide in Bipolar Disorder

    Science.gov (United States)

    Cassidy, Frederick

    2011-01-01

    Suicide rates of bipolar patients are among the highest of any psychiatric disorder, and improved identification of risk factors for attempted and completed suicide translates into improved clinical outcome. Factors that may be predictive of suicidality in an exclusively bipolar population are examined. White race, family suicide history, and…

  16. [Differences in Subjective Experience Between Unipolar and Bipolar Depression].

    Science.gov (United States)

    Fierro, Marco; Bustos, Andrés; Molina, Carlos

    2016-01-01

    It is important to make distinction between bipolar and unipolar depression because treatment and prognosis are different. Since the diagnosis of the two conditions is purely clinical, find symptomatic differences is useful. Find differences in subjective experience (first person) between unipolar and bipolar depression. Phenomenological-oriented qualitative exploratory study of 12 patients (7 with bipolar depression and 5 with unipolar depression, 3 men and 9 women). We used a semi-structured interview based on Examination of Anomalous Self-Experience (EASE). The predominant mood in bipolar depression is emotional dampening, in unipolar is sadness. The bodily experience in bipolar is of a heavy, tired body; an element that inserts between the desires of acting and performing actions and becomes an obstacle to the movement. In unipolar is of a body that feels more comfortable with the stillness than activity, like laziness of everyday life. Cognition and the stream of consciousness: in bipolar depression, compared with unipolar, thinking is slower, as if to overcome obstacles in their course. There are more difficult to understand what is heard or read. Future perspective: in bipolar depression, hopelessness is stronger and broader than in unipolar, as if the very possibility of hope was lost. Qualitative differences in predominant mood, bodily experience, cognition and future perspective were found between bipolar and unipolar depression. Copyright © 2015 Asociación Colombiana de Psiquiatría. Publicado por Elsevier España. All rights reserved.

  17. New types of bipolar fuzzy sets in -semihypergroups

    Directory of Open Access Journals (Sweden)

    Naveed Yaqoob

    2016-04-01

    Full Text Available The notion of bipolar fuzzy set was initiated by Lee (2000 as a generalization of the notion fuzzy sets and intuitionistic fuzzy sets, which have drawn attention of many mathematicians and computer scientists. In this paper, we initiate a study on bipolar ( , -fuzzy sets in -semihypergroups. By using the concept of bipolar ( , -fuzzy sets (Yaqoob and Ansari, 2013, we introduce the notion of bipolar ( , -fuzzy sub -semihypergroups (-hyperideals and bi--hyperideals and discuss some basic results on bipolar ( , -fuzzy sets in -semihypergroups. Furthermore, we define the bipolar fuzzy subset ,               and prove that if  ,       is a bipolar ( , -fuzzy sub -semihypergroup (resp., -hyperideal and bi--hyperideal of H; then ,               is also a bipolar ( , -fuzzy sub -semihypergroup (resp., -hyperideal and bi--hyperideal of H.

  18. Cortisol exposure, cognition and clinical course of bipolar disorder

    NARCIS (Netherlands)

    Spijker, Anne Titia

    2012-01-01

    In this dissertation, we aimed to identify the influence of cortisol exposure and cognitive performance on the clinical course of bipolar disorder. Data regarding sociodemographics, disease characteristics and genetic analysis of the cortisol receptors, were collected of 366 patients with bipolar

  19. Combinations of genetic variants associated with bipolar disorder

    DEFF Research Database (Denmark)

    Mellerup, Erling; Andreassen, Ole A; Bennike, Bente

    2017-01-01

    The main objective of the study was to find genetic variants that in combination are significantly associated with bipolar disorder. In previous studies of bipolar disorder, combinations of three and four single nucleotide polymorphisms (SNP) genotypes taken from 803 SNPs were analyzed, and five...... clusters of combinations were found to be significantly associated with bipolar disorder. In the present study, combinations of ten SNP genotypes taken from the same 803 SNPs were analyzed, and one cluster of combinations was found to be significantly associated with bipolar disorder. Combinations from......, heterozygote or variant homozygote. In the combinations containing 10 SNP genotypes almost all the genotypes were the normal homozygote. Such a finding may indicate that accumulation in the genome of combinations containing few SNP genotypes may be a risk factor for bipolar disorder when those combinations...

  20. Are working memory deficits in bipolar disorder markers for psychosis?

    Science.gov (United States)

    Allen, Daniel N; Randall, Carol; Bello, Danielle; Armstrong, Christina; Frantom, Linda; Cross, Chad; Kinney, Jefferson

    2010-03-01

    Working memory deficits have been identified in bipolar disorder, but there is evidence suggesting that these deficits may be markers for psychosis rather than affective disorder. The current study examined this issue by comparing two groups of individuals with bipolar disorder, one with psychotic features and one without psychotic features, with a group of normal controls. Working memory was conceptualized as a multicomponent system that includes auditory and visuospatial short-term stores, executive control processes, and an episodic buffer that allows for communication between short- and long-term memory stores (Baddeley & Logie, 1999). Results indicated that only executive control processes significantly differentiated the psychotic and nonpsychotic bipolar groups, although visuospatial working memory differentiated both bipolar groups from controls. The results support the idea that some aspects of working memory performance are markers for psychosis, while others may be more general markers for bipolar disorders. Copyright 2010 APA, all rights reserved

  1. Progress and challenges in bipolar lead-acid battery development

    Science.gov (United States)

    Bullock, Kathryn R.

    1995-05-01

    Bipolar lead-acid batteries have higher power densities than any other aqueous battery system. Predicted specific powers based on models and prototypes range from 800 kW/kg for 100 ms discharge times to 1.6 kW/kg for 10 s. A 48 V automotive bipolar battery could have 2 1/2 times the cold cranking rate of a monopolar 12 V design in the same size. Problems which have precluded the development of commercial bipolar designs include the instability of substrate materials and enhanced side reactions. Design approaches include pseudo-bipolar configurations, as well as true bipolar designs in planar and tubular configurations. Substrate materials used include lead and lead alloys, carbons, conductive ceramics, and tin-oxide-coated glass fibers. These approaches are reviewed and evaluated.

  2. Bipolar disorders and Wilson’s disease

    Directory of Open Access Journals (Sweden)

    Carta Mauro

    2012-05-01

    Full Text Available Abstract Background The aim of this study was to determine the risk for Bipolar Disorder (BD in Wilson’s disease (WD and to measure the impaired Quality of Life (QL in BD with WD using standardized psychiatric diagnostic tools and a case control design. Methods This was a case control study. The cases were 23 consecutive patients with WD treated at the University Hospital in Cagliari, Italy, and the controls were 92 sex- and age-matched subjects with no diagnosis of WD who were randomly selected from a database used previously for an epidemiological study. Psychiatric diagnoses according to DSM-IV criteria were determined by physicians using structured interview tools (ANTAS-SCID. QL was measured by means of SF-12. Results Compared to controls, WD patients had lower scores on the SF-12 and higher lifetime prevalence of DSM-IV major depressive disorders (OR = 5.7, 95% CI 2.4–17.3 and bipolar disorders (OR = 12.9, 95% CI 3.6–46.3. BD was associated with lower SF-12 in WD patients. Conclusions This study was the first to show an association between BD and WD using standardized diagnostic tools and a case control design. Reports in the literature about increased schizophrenia-like psychosis in WD and a lack of association with bipolar disorders may thus have been based on a more inclusive diagnosis of schizophrenia in the past. Our findings may explain the frequent reports of loss of emotional control, hyperactivity, loss of sexual inhibition, and irritability in WD patients. This study was limited by a small sample size.

  3. Fractura bipolar de clavícula

    OpenAIRE

    Zamora Navas, P.; Collado Torres, Francisco; Torre Solís, F. de la

    1994-01-01

    Se presenta un caso de fractura que afecta a ambos extremos de la clavícula. Fractura tipo II de Neer del fragmento distal y fractura del extremo esternal de la clavícula. Se realizó tratamiento quirúrgico mediante reducción abierta y osteosíntesis con agujas de Kirschner en ambas. El resultado a largo plazo ha sido satisfactorio cosmética y funcionalmente. A case of bipolar fracture affecting both ends of the clavicle is reported. The lesion consisted of a Neer type II fractur...

  4. Multikilowatt Bipolar Nickel/Hydrogen Battery

    Science.gov (United States)

    1986-01-01

    High energy densities appear feasible. Nickel/hydrogen battery utilizing bipolar construction in common pressure vessel, addressing needs for multikilowatt storage for low-Earth-orbit applications, designed and 10-cell prototype model tested. Modular-concept-design 35-kW battery projected energy densities of 20 to 24 Wh/b (160 to 190 kj/kg) and 700 to 900 Wh/ft3 (90 to 110 MJ/m3) and incorporated significant improvements over state-of-the-art storage systems.

  5. Dose Rate Effects in Linear Bipolar Transistors

    Science.gov (United States)

    Johnston, Allan; Swimm, Randall; Harris, R. D.; Thorbourn, Dennis

    2011-01-01

    Dose rate effects are examined in linear bipolar transistors at high and low dose rates. At high dose rates, approximately 50% of the damage anneals at room temperature, even though these devices exhibit enhanced damage at low dose rate. The unexpected recovery of a significant fraction of the damage after tests at high dose rate requires changes in existing test standards. Tests at low temperature with a one-second radiation pulse width show that damage continues to increase for more than 3000 seconds afterward, consistent with predictions of the CTRW model for oxides with a thickness of 700 nm.

  6. Bipolar nebulae and type I planetary nebulae

    International Nuclear Information System (INIS)

    Calvet, N.; Peimbert, M.

    1983-01-01

    It is suggested that the bipolar nature of PN of type I can be explained in terms of their relatively massive progenitors (Msub(i) 2.4 Msub(o)), that had to lose an appreciable fraction of their mass and angular momentum during their planetary nebulae stage. The following objects are discussed in relation with this suggestion: NGC 6302, NGC 2346, NGC 2440, CRL 618, Mz-3 and M2-9. It is found that CRL 618 is overbundant in N/O by a factor of 5-10 relative to the Orion Nebula. (author)

  7. A different perspective on bipolar disorder? : epidemiology, consequences, concept, and recognition of bipolar spectrum disorder in the general population

    NARCIS (Netherlands)

    Regeer, Eline Janet

    2008-01-01

    Bipolar disorder, or manic-depressive illness, is a mood disorder in which episodes of mania, hypomania and depression occur in alternation with intervals of normal mood. Bipolar disorder is typically a recurrent illness and may have serious consequences such as poor social and occupational

  8. Gender and Depressive Symptoms in 711 Patients With Bipolar Disorder Evaluated Prospectively in the Stanley Foundation Bipolar Treatment Outcome Network

    NARCIS (Netherlands)

    Altshuler, Lori L.; Kupka, Ralph W.; Hellemann, Gerhard; Frye, Mark A.; Sugar, Catherine A.; McElroy, Susan L.; Nolen, Willem A.; Grunze, Heinz; Leverich, Gabriele S.; Keck, Paul E.; Zermeno, Melanie

    Objective: The authors assessed gender differences in the proportion of clinical visits spent depressed, manic, or euthymic in patients with bipolar disorder. Method: Data were analyzed from 711 patients with bipolar I or II disorder who were followed prospectively over 7 years (13,191 visits). The

  9. Life events and bipolar disorder : The influence of life events on the onset and course of bipolar disorder

    NARCIS (Netherlands)

    Kemner, Sanne

    2017-01-01

    In the Netherlands, bipolar disorder (also known as manic-depressive illness) is diagnosed in approximately 2% of the population. The disorder is characterized by alternating periods of raised activity and (manic) mood and periods of reduced activity with lowered (depressed) mood. Bipolar disorder

  10. Quetiapine for the continuation treatment of bipolar depression : naturalistic prospective case series from the Stanley Bipolar Treatment Network

    NARCIS (Netherlands)

    Suppes, Trisha; Kelly, Dorothy I.; Keck, Paul E.; McElroy, Susan L.; Altshuler, Lori L.; Mintz, Jim; Frye, Mark A.; Nolen, Willem A.; Luckenbaugh, David A.; Post, Robert M.; Leverich, Gabriele S.; Kupka, Ralph W.; Grunze, Heinz

    Continuation treatment for bipolar disorder often consists of a mood stabilizer and a second-generation antipsychotic. Quetiapine has been shown to be an effective treatment for acute mania and acute bipolar depression, but there are limited data for its use in continuation treatment. This study

  11. Loopy: The Political Ontology of Bipolar Disorder

    Directory of Open Access Journals (Sweden)

    RACHEL JANE LIEBERT

    2013-01-01

    Full Text Available This essay is at once a critical analysis, an experiment in form, and – with some irony – a cautionary tale. Triggered by the inclusion of prodromal diagnoses in the fifth edition of the Diagnostic and Statistical Manual of Mental Disorders, and the recent call by the United States’ (U.S. Obama administration for increased mental health screening, I argue that shifts toward identifying and intervening on one’s potential madness, or risk, circulate with/in the contemporary U.S. climate of intensified discipline and terror, and use Bipolar Disorder as a site to critically explore how and with what implications this circulation occurs. Specifically, I weave Massumi’s ‘political ontology of threat’ with the narrative of a woman diagnosed with Bipolar Disorder in order to trace the pre-emptive politics and affective logic of a risk-based approach to madness. I contend that the diagnosing and drugging of potential is a self-perpetuating loop that is personally and politically harmful, and consider alternatives to this burgeoning practice.

  12. An overview of bipolar qualitative decision rules

    Science.gov (United States)

    Bonnefon, Jean-Francois; Dubois, Didier; Fargier, Hélène

    Making a good decision is often a matter of listing and comparing positive and negative arguments, as studies in cognitive psychology have shown. In such cases, the evaluation scale should be considered bipolar, that is, negative and positive values are explicitly distinguished. Generally, positive and negative features are evaluated separately, as done in Cumulative Prospect Theory. However, contrary to the latter framework that presupposes genuine numerical assessments, decisions are often made on the basis of an ordinal ranking of the pros and the cons, and focusing on the most salient features, i.e., the decision process is qualitative. In this paper, we report on a project aiming at characterizing several decision rules, based on possibilistic order of magnitude reasoning, and tailored for the joint handling of positive and negative affects, and at testing their empirical validity. The simplest rules can be viewed as extensions of the maximin and maximax criteria to the bipolar case and, like them, suffer from a lack of discrimination power. More decisive rules that refine them are also proposed. They account for both the principle of Pareto-efficiency and the notion of order of magnitude reasoning. The most decisive one uses a lexicographic ranking of the pros and cons. It comes down to a special case of Cumulative Prospect Theory, and subsumes the “Take the best” heuristic.

  13. Bipolar mood cycles and lunar tidal cycles.

    Science.gov (United States)

    Wehr, T A

    2018-04-01

    In 17 patients with rapid cycling bipolar disorder, time-series analyses detected synchronies between mood cycles and three lunar cycles that modulate the amplitude of the moon's semi-diurnal gravimetric tides: the 14.8-day spring-neap cycle, the 13.7-day declination cycle and the 206-day cycle of perigee-syzygies ('supermoons'). The analyses also revealed shifts among 1:2, 1:3, 2:3 and other modes of coupling of mood cycles to the two bi-weekly lunar cycles. These shifts appear to be responses to the conflicting demands of the mood cycles' being entrained simultaneously to two different bi-weekly lunar cycles with slightly different periods. Measurements of circadian rhythms in body temperature suggest a biological mechanism through which transits of one of the moon's semi-diurnal gravimetric tides might have driven the patients' bipolar cycles, by periodically entraining the circadian pacemaker to its 24.84-h rhythm and altering the pacemaker's phase-relationship to sleep in a manner that is known to cause switches from depression to mania.

  14. The efficacy of Li in bipolar disorder

    Directory of Open Access Journals (Sweden)

    Lozano R

    2013-07-01

    Full Text Available R Lozano,1 R Marín,2 MJ Santacruz,2 I Freire,2 R Gomez21Department of Pharmacy, 2Department of Psychiatry, Hospital Real Nuestra Señora de Gracia, Zaragoza, SpainThe efficacy of lithium (Li for acute mania and as prophylaxis against recurrent episodes of mania in bipolar disorder has been well established, with the minimum effective Li serum concentration for acute mania in the range of 0.6–1.2 mEq/L, although lower maintenance concentrations can prove effective in some patients.1–5Thyroid disorders are also associated with alterations in mood, and patients with hypothyroidism may present with depression and cognitive dysfunction,6–8 while patients with hyperthyroidism may present with anxiety, depression, mood lability,7,9 and manic symptoms.10 However, considering that overt hyperthyroidism is uncommon in bipolar disorder, with a prevalence ≤2% across different studies,11,12 this has been largely attributed to lithium,13 with rates varying from 0 to 47% (average of about 10% among patients on long-term treatment with lithium.13–16

  15. High-performance silicon nanowire bipolar phototransistors

    Science.gov (United States)

    Tan, Siew Li; Zhao, Xingyan; Chen, Kaixiang; Crozier, Kenneth B.; Dan, Yaping

    2016-07-01

    Silicon nanowires (SiNWs) have emerged as sensitive absorbing materials for photodetection at wavelengths ranging from ultraviolet (UV) to the near infrared. Most of the reports on SiNW photodetectors are based on photoconductor, photodiode, or field-effect transistor device structures. These SiNW devices each have their own advantages and trade-offs in optical gain, response time, operating voltage, and dark current noise. Here, we report on the experimental realization of single SiNW bipolar phototransistors on silicon-on-insulator substrates. Our SiNW devices are based on bipolar transistor structures with an optically injected base region and are fabricated using CMOS-compatible processes. The experimentally measured optoelectronic characteristics of the SiNW phototransistors are in good agreement with simulation results. The SiNW phototransistors exhibit significantly enhanced response to UV and visible light, compared with typical Si p-i-n photodiodes. The near infrared responsivities of the SiNW phototransistors are comparable to those of Si avalanche photodiodes but are achieved at much lower operating voltages. Compared with other reported SiNW photodetectors as well as conventional bulk Si photodiodes and phototransistors, the SiNW phototransistors in this work demonstrate the combined advantages of high gain, high photoresponse, low dark current, and low operating voltage.

  16. Potential for thermal damage to the blood–brain barrier during craniotomy: implications for intracortical recording microelectrodes

    Science.gov (United States)

    Shoffstall, Andrew J.; Paiz, Jen E.; Miller, David M.; Rial, Griffin M.; Willis, Mitchell T.; Menendez, Dhariyat M.; Hostler, Stephen R.; Capadona, Jeffrey R.

    2018-06-01

    Objective. Our objective was to determine how readily disruption of the blood–brain barrier (BBB) occurred as a result of bone drilling during a craniotomy to implant microelectrodes in rat cortex. While the phenomenon of heat production during bone drilling is well known, practices to evade damage to the underlying brain tissue are inconsistently practiced and reported in the literature. Approach. We conducted a review of the intracortical microelectrode literature to summarize typical approaches to mitigate drill heating during rodent craniotomies. Post mortem skull-surface and transient brain-surface temperatures were experimentally recorded using an infrared camera and thermocouple, respectively. A number of drilling conditions were tested, including varying drill speed and continuous versus intermittent contact. In vivo BBB permeability was assayed 1 h after the craniotomy procedure using Evans blue dye. Main results. Of the reviewed papers that mentioned methods to mitigate thermal damage during craniotomy, saline irrigation was the most frequently cited (in six of seven papers). In post mortem tissues, we observed increases in skull-surface temperature ranging from  +3 °C to  +21 °C, dependent on drill speed. In vivo, pulsed-drilling (2 s-on/2 s-off) and slow-drilling speeds (1000 r.p.m.) were the most effective methods we studied to mitigate heating effects from drilling, while inconclusive results were obtained with saline irrigation. Significance. Neuroinflammation, initiated by damage to the BBB and perpetuated by the foreign body response, is thought to play a key role in premature failure of intracortical recording microelectrodes. This study demonstrates the extreme sensitivity of the BBB to overheating caused by bone drilling. To avoid damage to the BBB, the authors recommend that craniotomies be drilled with slow speeds and/or with intermittent drilling with complete removal of the drill from the skull during ‘off’ periods. While

  17. Transtorno bipolar do humor e gênero Bipolar affective disorder and gender

    Directory of Open Access Journals (Sweden)

    Rodrigo da Silva Dias

    2006-01-01

    Full Text Available Embora o transtorno bipolar (TB ocorra quase igualmente em ambos os sexos, a fenomenologia e o curso da doença diferem no homem e na mulher. No entanto, há evidências de que mulheres bipolares, mais que os homens, apresentariam início mais tardio (em especial na quinta década de vida, ciclagem rápida, mais episódios depressivos, mais mania disfórica que eufórica, estados mistos e evolução do tipo bipolar II, ainda que os achados nem sempre sejam consistentes. Embora o risco de comorbidades no TB inclua, para ambos os gêneros, abuso de álcool e drogas, homens bipolares teriam maior probabilidade de ser alcoolistas, não procurar tratamento e de se suicidar. Hipóteses sugeridas para explicar tais diferenças variam daquelas centradas em aspectos culturais ou psicológicos para as que focalizam os sistemas hormonais, como os esteróides gonadais ou o eixo tireoidiano, e até mesmo a anatomia cerebral. A influência do ciclo reprodutivo (ciclo menstrual, gravidez e menopausa sobre as opções terapêuticas no tratamento do TB é apresentada na última parte desta revisão.Although the bipolar disorder (BD occurs almost with the same frequency in both genders, the phenomenology and the outcome of the illness differ between them. Nevertheless, there is evidence that women with BD show, more than men, delayed beginning, especially in their fifth decade, more rapid cycling outcome, more depressive episodes, more dysphoric mania, more mixed states and more BD type II. Even so, the findings are not always consistent. Although the risk of comorbidities in BD includes, for both the sorts, excessive alcoholic consumption and drugs, bipolar men would have greater probability of being alcohol dependent, of not seeking treatment and of committing suicide. Suggested hypotheses to explain such differences vary from those centered in cultural or psychological aspects to those that focus on the steroids hormones, and other hormones such as cortisol

  18. A Microelectrode Array with Reproducible Performance Shows Loss of Consistency Following Functionalization with a Self-Assembled 6-Mercapto-1-hexanol Layer

    Directory of Open Access Journals (Sweden)

    Damion K. Corrigan

    2018-06-01

    Full Text Available For analytical applications involving label-free biosensors and multiple measurements, i.e., across an electrode array, it is essential to develop complete sensor systems capable of functionalization and of producing highly consistent responses. To achieve this, a multi-microelectrode device bearing twenty-four equivalent 50 µm diameter Pt disc microelectrodes was designed in an integrated 3-electrode system configuration and then fabricated. Cyclic voltammetry and electrochemical impedance spectroscopy were used for initial electrochemical characterization of the individual working electrodes. These confirmed the expected consistency of performance with a high degree of measurement reproducibility for each microelectrode across the array. With the aim of assessing the potential for production of an enhanced multi-electrode sensor for biomedical use, the working electrodes were then functionalized with 6-mercapto-1-hexanol (MCH. This is a well-known and commonly employed surface modification process, which involves the same principles of thiol attachment chemistry and self-assembled monolayer (SAM formation commonly employed in the functionalization of electrodes and the formation of biosensors. Following this SAM formation, the reproducibility of the observed electrochemical signal between electrodes was seen to decrease markedly, compromising the ability to achieve consistent analytical measurements from the sensor array following this relatively simple and well-established surface modification. To successfully and consistently functionalize the sensors, it was necessary to dilute the constituent molecules by a factor of ten thousand to support adequate SAM formation on microelectrodes. The use of this multi-electrode device therefore demonstrates in a high throughput manner irreproducibility in the SAM formation process at the higher concentration, even though these electrodes are apparently functionalized simultaneously in the same film

  19. An investigation of coated aluminium bipolar plates for PEMFC

    International Nuclear Information System (INIS)

    Lin, Chien-Hung; Tsai, Sung-Ying

    2012-01-01

    Highlights: ► Coated aluminium bipolar plates demonstrate the hydrophobic property than the raw material. ► The corrosion behaviour of bipolar plate decreases the PEMFC performance severely. ► These PEMFCs are measured by current–voltage (I–V) curve test. ► The oxide film increases the interfacial contact resistance. -- Abstract: The performance of Al-alloy bipolar plates for the PEMFC (proton exchange membrane fuel cell) system is investigated in this paper. The metallic bipolar plates are modified with a Ni–P coating. The performance of the Al-alloy bipolar plates is evaluated by the coating structure, corrosion resistance, contact angle and single cell performance. The results indicate that the coated aluminium bipolar plates demonstrate hydrophobic and anti-corrosive properties. The hydrophobic property increases the contact angle on the surface from 46.08° to 80.51°. Meanwhile, the corrosion rate of the Ni–P coating can be over 1 order of magnitude lower than that of the substrate. Hence, the substrate with the coating maintains superior performance under the long term test. The present study proves that both the hydrophobicity and corrosion resistance significantly affect the metallic bipolar plate.

  20. Carbon dioxide induces erratic respiratory responses in bipolar disorder.

    Science.gov (United States)

    Mackinnon, Dean F; Craighead, Brandie; Lorenz, Laura

    2009-01-01

    CO(2) respiration stimulates both anxiety and dyspnea ("air hunger") and has long been used to study panic vulnerability and respiratory control. High comorbidity with panic attacks suggests individuals with bipolar disorder may also mount a heightened anxiety response to CO(2). Moreover, problems in the arousal and modulation of appetites are central to the clinical syndromes of mania and depression; hence CO(2) may arouse an abnormal respiratory response to "air hunger". 72 individuals (34 bipolar I, 25 depressive and bipolar spectrum, 13 with no major affective diagnosis) breathed air and air with 5% CO(2) via facemask for up to 15 min each; subjective and respiratory responses were recorded. Nearly half the subjects diverged from the typical response to a fixed, mildly hypercapneic environment, which is to increase breathing acutely, and then maintain a hyperpneic plateau. The best predictors of an abnormal pattern were bipolar diagnosis and anxiety from air alone. 25 individuals had a panic response; panic responses from CO(2) were more likely in subjects with bipolar I compared to other subjects, however the best predictors of a panic response overall were anxiety from air alone and prior history of panic attacks. Heterogeneous sample, liberal definition of panic attack. Carbon dioxide produces abnormal respiratory and heightened anxiety responses among individuals with bipolar and depressive disorders. These may be due to deficits in emotional conditioning related to fear and appetite. Although preliminary, this work suggests a potentially useful test of a specific functional deficit in bipolar disorder.

  1. Bipolar disorder and dementia: where is the link?

    Science.gov (United States)

    Masouy, Anaïs; Chopard, Gilles; Vandel, Pierre; Magnin, Eloi; Rumbach, Lucien; Sechter, Daniel; Haffen, Emmanuel

    2011-03-01

    Cognitive disorders appearing in the course of bipolar disease have been identified, and recent studies have defined the neuropsychological characteristics of this pathology, which includes attention, executive function, memory and language disorders. However, questions remain concerning the appearance of dementia symptoms over the course of bipolar disorder in certain patients: is it a chance association or is there a connection between bipolar disorders and dementia? If the latter hypothesis is considered, what is the nature of the dementia, which might be considered as a dementia specific to bipolar disorder? Current clinical, neuropsychological and cerebral imaging data are inconclusive, but similarities with frontotemporal dementia might be highlighted. Functional imaging studies might provide answers as well as more specific tests in neuropsychology. The cause of cognitive damage in bipolar disease also raises questions concerning a neurodevelopmental or neurodegenerative process, because several factors seem to influence cognition and these two processes might occur simultaneously. Long-term studies are necessary to determine whether cognitive deterioration in bipolar disease is stable or progressive. There might also be different neurobiological subgroups of patients with bipolar disease. © 2011 The Authors. Psychogeriatrics © 2011 Japanese Psychogeriatric Society.

  2. Suicide attempts and clinical features of bipolar patients.

    Science.gov (United States)

    Berkol, Tonguç D; İslam, Serkan; Kırlı, Ebru; Pınarbaşı, Rasim; Özyıldırım, İlker

    2016-06-01

    To identify clinical predictors of suicide attempts in patients with bipolar disorder. This study included bipolar patients who were treated in the Psychiatry Department, Haseki Training and Research Hospital, Istanbul, Turkey, between 2013 and 2014; an informed consent was obtained from the participants. Two  hundred and eighteen bipolar patients were assessed by using the structured clinical interview for Diagnostic and Statistical Manual of Mental Disorders, 4th edition (DSM-IV) Axis-I (SCID-I) in order to detect all possible psychiatric comorbid diagnoses. Clinical predictors of suicide attempts were examined in attempters and non-attempters. The study design was retrospective. The lifetime suicide attempt rate for the entire sample was 19.2%. Suicide attempters with bipolar disorder had more lifetime comorbidity of eating disorder. Female gender and family history of mood disorder were significant predictors for suicide attempts. There was no difference between groups in terms of bipolar disorder subtype, onset age of bipolar disorder, total number of episodes, first and predominant episode type, suicide history in first degree relatives, severity of episodes, and hospitalization and being psychotic. Our study revealed that female gender, family history of mood disorder, and eating disorder are more frequent in bipolar patients with at least one suicide attempt.

  3. Evidence for genetic association of RORB with bipolar disorder

    Directory of Open Access Journals (Sweden)

    Mick Eric

    2009-11-01

    Full Text Available Abstract Background Bipolar disorder, particularly in children, is characterized by rapid cycling and switching, making circadian clock genes plausible molecular underpinnings for bipolar disorder. We previously reported work establishing mice lacking the clock gene D-box binding protein (DBP as a stress-reactive genetic animal model of bipolar disorder. Microarray studies revealed that expression of two closely related clock genes, RAR-related orphan receptors alpha (RORA and beta (RORB, was altered in these mice. These retinoid-related receptors are involved in a number of pathways including neurogenesis, stress response, and modulation of circadian rhythms. Here we report association studies between bipolar disorder and single-nucleotide polymorphisms (SNPs in RORA and RORB. Methods We genotyped 355 RORA and RORB SNPs in a pediatric cohort consisting of a family-based sample of 153 trios and an independent, non-overlapping case-control sample of 152 cases and 140 controls. Bipolar disorder in children and adolescents is characterized by increased stress reactivity and frequent episodes of shorter duration; thus our cohort provides a potentially enriched sample for identifying genes involved in cycling and switching. Results We report that four intronic RORB SNPs showed positive associations with the pediatric bipolar phenotype that survived Bonferroni correction for multiple comparisons in the case-control sample. Three RORB haplotype blocks implicating an additional 11 SNPs were also associated with the disease in the case-control sample. However, these significant associations were not replicated in the sample of trios. There was no evidence for association between pediatric bipolar disorder and any RORA SNPs or haplotype blocks after multiple-test correction. In addition, we found no strong evidence for association between the age-at-onset of bipolar disorder with any RORA or RORB SNPs. Conclusion Our findings suggest that clock genes in

  4. Identifying early indicators in bipolar disorder: a qualitative study.

    Science.gov (United States)

    Benti, Liliane; Manicavasagar, Vijaya; Proudfoot, Judy; Parker, Gordon

    2014-06-01

    The identification of early markers has become a focus for early intervention in bipolar disorder. Using a retrospective, qualitative methodology, the present study compares the early experiences of participants with bipolar disorder to those with unipolar depression up until their first diagnosed episode. The study focuses on differences in early home and school environments as well as putative differences in personality characteristics between the two groups. Finally we a compare and contrast prodromal symptoms in these two populations. Thirty-nine participants, 20 diagnosed with unipolar depression and 19 diagnosed with bipolar disorder, took part in the study. A semi-structured interview was developed to elicit information about participants' experiences prior to their first episode. Participants with bipolar disorder reported disruptive home environments, driven personality features, greater emotion dysregulation and adverse experiences during the school years, whereas participants with depression tended to describe more supportive home environments, and more compliant and introvert personality traits. Retrospective data collection and no corroborative evidence from other family members. No distinction was made between bipolar I and bipolar II disorder nor between melancholic and non-melancholic depression in the sample. Finally the study spanned over a 12-month period which does not allow for the possibility of diagnostic reassignment of some of the bipolar participants to the unipolar condition. These findings indicate that there may be benefits in combining both proximal and distal indicators in identifying a bipolar disorder phenotype which, in turn, may be relevant to the development of early intervention programs for young people with bipolar disorder.

  5. Bipolar Disorder and the TCI: Higher Self-Transcendence in Bipolar Disorder Compared to Major Depression.

    Science.gov (United States)

    Harley, James A; Wells, J Elisabeth; Frampton, Christopher M A; Joyce, Peter R

    2011-01-01

    Personality traits are potential endophenotypes for genetic studies of psychiatric disorders. One personality theory which demonstrates strong heritability is Cloninger's psychobiological model measured using the temperament and character inventory (TCI). 277 individuals who completed the TCI questionnaire as part of the South Island Bipolar Study were also interviewed to assess for lifetime psychiatric diagnoses. Four groups were compared, bipolar disorder (BP), type 1 and 2, MDD (major depressive disorder), and nonaffected relatives of a proband with BP. With correction for mood state, total harm avoidance (HA) was higher than unaffected in both MDD and BP groups, but the mood disorder groups did not differ from each other. However, BP1 individuals had higher self-transcendence (ST) than those with MDD and unaffected relatives. HA may reflect a trait marker of mood disorders whereas high ST may be specific to BP. As ST is heritable, genes that affect ST may be of relevance for vulnerability to BP.

  6. Intervenções psicossociais no transtorno bipolar Psychosocial interventions for bipolar disorder

    Directory of Open Access Journals (Sweden)

    Luis Pereira Justo

    2004-01-01

    Full Text Available Neste trabalho, os autores, através de revisão bibliográfica narrativa, situam as intervenções psicossociais dentro do panorama terapêutico para o transtorno bipolar e constatam que ainda são insuficientes os estudos primários feitos com metodologia adequada para a obtenção de informações científicas de boa qualidade. São sucintamente descritos os trabalhos mais relevantes.In this paper, the authors review the status of psychosocial interventions within the general treatment for bipolar disorder. They have verified the scantiness of studies performed with adequate methodology to obtain scientific information of good quality. The more relevant studies are briefly described.

  7. In vivo pH monitoring using boron doped diamond microelectrode and silver needles: Application to stomach disorder diagnosis

    Science.gov (United States)

    Fierro, Stéphane; Seishima, Ryo; Nagano, Osamu; Saya, Hideyuki; Einaga, Yasuaki

    2013-11-01

    This study presents the in vivo electrochemical monitoring of pH using boron doped diamond (BDD) microelectrode and silver needles for potential application in medical diagnosis. Accurate calibration curve for pH determination were obtained through in vitro electrochemical measurements. The increase induced in stomach pH by treatment with pantoprazole was used to demonstrate that it is possible to monitor the pH in vivo using the simple and noninvasive system proposed herein. Using the results of the in vivo and in vitro experiments, a quantitative analysis of the increase in stomach pH is also presented. It is proposed that the catheter-free pH monitoring system presented in this study could be potentially employed in any biological environment.

  8. Noninvasive microelectrode ion flux estimation technique (MIFE) for the study of the regulation of root membrane transport by cyclic nucleotides

    KAUST Repository

    Ordoñ ez, Natalia Maria; Shabala, Lana; Gehring, Christoph A; Shabala, Sergey Nikolayevich

    2013-01-01

    Changes in ion permeability and subsequently intracellular ion concentrations play a crucial role in intracellular and intercellular communication and, as such, confer a broad array of developmental and adaptive responses in plants. These changes are mediated by the activity of plasma-membrane based transport proteins many of which are controlled by cyclic nucleotides and/or other signaling molecules. The MIFE technique for noninvasive microelectrode ion flux measuring allows concurrent quantification of net fluxes of several ions with high spatial (μm range) and temporal (ca. 5 s) resolution, making it a powerful tool to study various aspects of downstream signaling events in plant cells. This chapter details basic protocols enabling the application of the MIFE technique to study regulation of root membrane transport in general and cyclic nucleotide mediated transport in particular. © Springer Science+Business Media New York 2013.

  9. Rapid capacitive detection of femtomolar levels of bisphenol A using an aptamer-modified disposable microelectrode array

    International Nuclear Information System (INIS)

    Cui, Haochen; Wu, Jayne; Eda, Shigetoshi; Chen, Jiangang; Chen, Wei; Zheng, Lei

    2015-01-01

    A label-free and single-step method is reported for rapid and highly sensitive detection of bisphenol A (BPA) in aqueous samples. It utilizes an aptamer acting as a probe molecule immobilized on a commercially available array of interdigitated aluminum microelectrodes. BPA was quantified by measuring the interfacial capacitance change rate caused by the specific binding between bisphenol A and the immobilized aptamer. The AC signal also induces an AC electrokinetic effect to generate microfluidic motion for enhanced binding. The capacitive aptasensor achieves a limit of detection as low as 10 fM(2.8 fg ⋅ mL −1 ) with a 20 s response time. The method is inexpensive, highly sensitive, rapid and therefore provides a promising technology for on-site detection of BPA in food and water samples. (author)

  10. Multiple single-unit long-term tracking on organotypic hippocampal slices using high-density microelectrode arrays

    Directory of Open Access Journals (Sweden)

    Wei Gong

    2016-11-01

    Full Text Available A novel system to cultivate and record from organotypic brain slices directly on high-density microelectrode arrays (HD-MEA was developed. This system allows for continuous recording of electrical activity of specific individual neurons at high spatial resolution while monitoring at the same time, neuronal network activity. For the first time, the electrical activity patterns of single neurons and the corresponding neuronal network in an organotypic hippocampal slice culture were studied during several consecutive weeks at daily intervals. An unsupervised iterative spike-sorting algorithm, based on PCA and k-means clustering, was developed to assign the activities to the single units. Spike-triggered average extracellular waveforms of an action potential recorded across neighboring electrodes, termed ‘footprints’ of single-units were generated and tracked over weeks. The developed system offers the potential to study chronic impacts of drugs or genetic modifications on individual neurons in slice preparations over extended times.

  11. Noninvasive microelectrode ion flux estimation technique (MIFE) for the study of the regulation of root membrane transport by cyclic nucleotides

    KAUST Repository

    Ordoñez, Natalia Maria

    2013-09-03

    Changes in ion permeability and subsequently intracellular ion concentrations play a crucial role in intracellular and intercellular communication and, as such, confer a broad array of developmental and adaptive responses in plants. These changes are mediated by the activity of plasma-membrane based transport proteins many of which are controlled by cyclic nucleotides and/or other signaling molecules. The MIFE technique for noninvasive microelectrode ion flux measuring allows concurrent quantification of net fluxes of several ions with high spatial (μm range) and temporal (ca. 5 s) resolution, making it a powerful tool to study various aspects of downstream signaling events in plant cells. This chapter details basic protocols enabling the application of the MIFE technique to study regulation of root membrane transport in general and cyclic nucleotide mediated transport in particular. © Springer Science+Business Media New York 2013.

  12. Functional characterization of GABAA receptor-mediated modulation of cortical neuron network activity in microelectrode array recordings

    DEFF Research Database (Denmark)

    Bader, Benjamin M; Steder, Anne; Klein, Anders Bue

    2017-01-01

    The numerous γ-aminobutyric acid type A receptor (GABAAR) subtypes are differentially expressed and mediate distinct functions at neuronal level. In this study we have investigated GABAAR-mediated modulation of the spontaneous activity patterns of primary neuronal networks from murine frontal...... of the information extractable from the MEA recordings offers interesting insights into the contributions of various GABAAR subtypes/subgroups to cortical network activity and the putative functional interplay between these receptors in these neurons....... cortex by characterizing the effects induced by a wide selection of pharmacological tools at a plethora of activity parameters in microelectrode array (MEA) recordings. The basic characteristics of the primary cortical neurons used in the recordings were studied in some detail, and the expression levels...

  13. Planar potentiometric sensors based on Au and Ag microelectrodes and conducting polymers for flow-cell analysis

    International Nuclear Information System (INIS)

    ToczyIowska, Renata; Pokrop, RafaI; Dybko, Artur; Wroblewski, Wojciech

    2005-01-01

    Back-side contact Au and Ag microelectrodes were used as transducers to construct planar all-solid-state electrodes suitable for flow-through analysis. The microsensors were based on plasticized PVC potassium-selective membranes containing ion-electron conducting polymer-polypyrrole doped with di(2-ethylhexyl) sulfosuccinate. The proposed technique allowed simple construction of microsensors in one step, by membrane solution casting directly on the surface of the planar metallic transducers. The performance of the microsensors based on Au and Ag transducers were determined and compared with planar sensors based on internal electrolyte immobilized in polyHEMA. The addition of the polypyrrole to the membrane composition did not influence on the selectivity, reproducibility and long-term stability of the microsensors but improved their standard potential stability in time in comparison with coated-wire type sensors. Moreover, all-solid-state microsensors based on Au transducers exhibited better signal stability than Ag based sensors

  14. Unipolar and bipolar diffusion charging of ultrafine particles

    International Nuclear Information System (INIS)

    Adachi, Motoaki; Okuyama, Kikuo; Kousaka, Yasuo.

    1985-01-01

    Unipolar and bipolar diffusion charging of monodisperse ultrafine particles of 4 - 100 nm in diameter has been studied experimentally and theoretically. The particles were charged by unipolar and bipolar ions generated by α-ray irradiation and the charge distribution of particles was directly observed in the electric field after the growth of them by condensation of di-butyl phthalate vapor. In both cases of unipolar and bipolar charging, the experimental results have been found in good agreement with the solution of basic equations where Fuchs' formula is used as the combination probability of an ion with a particle. (author)

  15. Bipolar nickel-hydrogen battery development - A program review

    Science.gov (United States)

    Manzo, Michelle; Lenhart, Stephen; Hall, Arnold

    1989-01-01

    An overview of spacecraft power system design trends, focusing on higher power bus voltages and improved energy storage systems, is followed by a discussion of bipolar Ni/H2 battery development efforts. Several 10-cell batteries and one 50-cell battery are described, and performance results are presented. A comparison of individual-pressure-vessel and bipolar Ni/H2 technologies is used to suggest a new direction for bipolar Ni/H2 battery development efforts, toward a large number of passively cooled cells in parallel.

  16. Retinal bipolar cells: elementary building blocks of vision.

    Science.gov (United States)

    Euler, Thomas; Haverkamp, Silke; Schubert, Timm; Baden, Tom

    2014-08-01

    Retinal bipolar cells are the first ‘projection neurons’ of the vertebrate visual system—all of the information needed for vision is relayed by this intraretinal connection. Each of the at least 13 distinct types of bipolar cells systematically transforms the photoreceptor input in a different way, thereby generating specific channels that encode stimulus properties, such as polarity, contrast, temporal profile and chromatic composition. As a result, bipolar cell output signals represent elementary ‘building blocks’ from which the microcircuits of the inner retina derive a feature-oriented description of the visual world.

  17. Inhibitory effects of ZnO nanoparticles on aerobic wastewater biofilms from oxygen concentration profiles determined by microelectrodes

    International Nuclear Information System (INIS)

    Hou, Jun; Miao, Lingzhan; Wang, Chao; Wang, Peifang; Ao, Yanhui; Qian, Jin; Dai, Shanshan

    2014-01-01

    Highlights: • Temporal and spatial inhibitory effects of ZnO NPs on biofilms were investigated. • 50 mg/L nano-ZnO inhibited the microbial activities only in biofilm outer layer. • Adsorbed ZnO NPs had no adverse effects on the cell membrane integrity of biofilms. • Dissolution of ZnO NPs to toxic zinc ions was the main mechanism of toxicity. - Abstract: The presence of ZnO NPs in waste streams can negatively affect the efficiency of biological nutrient removal from wastewater. However, details of the toxic effects of ZnO NPs on microbial activities of wastewater biofilms have not yet been reported. In this study, the temporal and spatial inhibitory effects of ZnO NPs on the O 2 respiration activities of aerobic wastewater biofilms were investigated using an O 2 microelectrode. The resulting time–course microelectrode measurements demonstrated that ZnO NPs inhibited O 2 respiration within 2 h. The spatial distributions of net specific O 2 respiration were determined in biofilms with and without treatment of 5 or 50 mg/L ZnO NPs. The results showed that 50 mg/L of nano-ZnO inhibited the microbial activities only in the outer layer (∼200 μm) of the biofilms, and bacteria present in the deeper parts of the biofilms became even more active. Scanning electron microscopy (SEM) analysis showed that the ZnO NPs were adsorbed onto the biofilm, but these NPs had no adverse effects on the cell membrane integrity of the biofilms. It was found that the inhibition of O 2 respiration induced by higher concentrations of ZnO NPs (50 mg/L) was mainly due to the release of zinc ions by dissolution of the ZnO NPs

  18. Bio-inspired hybrid microelectrodes: a hybrid solution to improve long-term performance of chronic intracortical implants.

    Science.gov (United States)

    De Faveri, Sara; Maggiolini, Emma; Miele, Ermanno; De Angelis, Francesco; Cesca, Fabrizia; Benfenati, Fabio; Fadiga, Luciano

    2014-01-01

    The use of implants that allow chronic electrical stimulation and recording in the brain of human patients is currently limited by a series of events that cause the deterioration over time of both the electrode surface and the surrounding tissue. The main reason of failure is the tissue inflammatory reaction that eventually causes neuronal loss and glial encapsulation, resulting in a progressive increase of the electrode-electrolyte impedance. Here, we describe a new method to create bio-inspired electrodes to mimic the mechanical properties and biological composition of the host tissue. This combination has a great potential to increase the implant lifetime by reducing tissue reaction and improving electrical coupling. Our method implies coating the electrode with reprogrammed neural or glial cells encapsulated within a hydrogel layer. We chose fibrin as a hydrogel and primary hippocampal neurons or astrocytes from rat brain as cellular layer. We demonstrate that fibrin coating is highly biocompatible, forms uniform coatings of controllable thickness, does not alter the electrochemical properties of the microelectrode and allows good quality recordings. Moreover, it reduces the amount of host reactive astrocytes - over time - compared to a bare wire and is fully reabsorbed by the surrounding tissue within 7 days after implantation, avoiding the common problem of hydrogels swelling. Both astrocytes and neurons could be successfully grown onto the electrode surface within the fibrin hydrogel without altering the electrochemical properties of the microelectrode. This bio-hybrid device has therefore a good potential to improve the electrical integration at the neuron-electrode interface and support the long-term success of neural prostheses.

  19. Bio-inspired hybrid microelectrodes. A hybrid solution to improve long-term performance of chronic intracortical implants.

    Directory of Open Access Journals (Sweden)

    Sara eDe Faveri

    2014-04-01

    Full Text Available The use of implants that allow chronic electrical stimulation and recording in the brain of human patients is currently limited by a series of events that cause the deterioration over time of both the electrode surface and the surrounding tissue. The main reason of failure is the tissue inflammatory reaction that eventually causes neuronal loss and glial encapsulation, resulting in a progressive increase of the electrode-electrolyte impedance. Here, we describe a new method to create bio-inspired electrodes to mimic the mechanical properties and biological composition of the host tissue. This combination has a great potential to increase the implant lifetime by reducing tissue reaction and improving electrical coupling. Our method implies coating the electrode with reprogrammed neural or glial cells encapsulated within a hydrogel layer. We chose fibrin as a hydrogel and primary hippocampal neurons or astrocytes from rat brain as cellular layer. We demonstrate that fibrin coating is highly biocompatible, forms uniform coatings of controllable thickness, does not alter the electrochemical properties of the microelectrode and allows good quality recordings. Moreover, it reduces the amount of host reactive astrocytes - over time - compared to a bare wire and is fully reabsorbed by the surrounding tissue within 7 days after implantation, avoiding the common problem of hydrogels swelling. Both astrocytes and neurons could be successfully grown onto the electrode surface within the fibrin hydrogel without altering the electrochemical properties of the microelectrode. This bio-hybrid device has therefore a good potential to improve the electrical integration at the neuron-electrode interface and support the long-term success of neural prostheses.

  20. Inhibitory effects of ZnO nanoparticles on aerobic wastewater biofilms from oxygen concentration profiles determined by microelectrodes

    Energy Technology Data Exchange (ETDEWEB)

    Hou, Jun [Key Laboratory of Integrated Regulation and Resources Development on Shallow Lakes, Ministry of Education, Hohai University, Nanjing 210098 (China); College of Environment, Hohai University, Nanjing 210098 (China); Miao, Lingzhan, E-mail: mlz1988@126.com [Key Laboratory of Integrated Regulation and Resources Development on Shallow Lakes, Ministry of Education, Hohai University, Nanjing 210098 (China); College of Environment, Hohai University, Nanjing 210098 (China); Wang, Chao, E-mail: hhuhjy973@126.com [Key Laboratory of Integrated Regulation and Resources Development on Shallow Lakes, Ministry of Education, Hohai University, Nanjing 210098 (China); College of Environment, Hohai University, Nanjing 210098 (China); Wang, Peifang; Ao, Yanhui; Qian, Jin; Dai, Shanshan [Key Laboratory of Integrated Regulation and Resources Development on Shallow Lakes, Ministry of Education, Hohai University, Nanjing 210098 (China); College of Environment, Hohai University, Nanjing 210098 (China)

    2014-07-15

    Highlights: • Temporal and spatial inhibitory effects of ZnO NPs on biofilms were investigated. • 50 mg/L nano-ZnO inhibited the microbial activities only in biofilm outer layer. • Adsorbed ZnO NPs had no adverse effects on the cell membrane integrity of biofilms. • Dissolution of ZnO NPs to toxic zinc ions was the main mechanism of toxicity. - Abstract: The presence of ZnO NPs in waste streams can negatively affect the efficiency of biological nutrient removal from wastewater. However, details of the toxic effects of ZnO NPs on microbial activities of wastewater biofilms have not yet been reported. In this study, the temporal and spatial inhibitory effects of ZnO NPs on the O{sub 2} respiration activities of aerobic wastewater biofilms were investigated using an O{sub 2} microelectrode. The resulting time–course microelectrode measurements demonstrated that ZnO NPs inhibited O{sub 2} respiration within 2 h. The spatial distributions of net specific O{sub 2} respiration were determined in biofilms with and without treatment of 5 or 50 mg/L ZnO NPs. The results showed that 50 mg/L of nano-ZnO inhibited the microbial activities only in the outer layer (∼200 μm) of the biofilms, and bacteria present in the deeper parts of the biofilms became even more active. Scanning electron microscopy (SEM) analysis showed that the ZnO NPs were adsorbed onto the biofilm, but these NPs had no adverse effects on the cell membrane integrity of the biofilms. It was found that the inhibition of O{sub 2} respiration induced by higher concentrations of ZnO NPs (50 mg/L) was mainly due to the release of zinc ions by dissolution of the ZnO NPs.

  1. Electrostatic Spray Deposition-Based Manganese Oxide Films-From Pseudocapacitive Charge Storage Materials to Three-Dimensional Microelectrode Integrands.

    Science.gov (United States)

    Agrawal, Richa; Adelowo, Ebenezer; Baboukani, Amin Rabiei; Villegas, Michael Franc; Henriques, Alexandra; Wang, Chunlei

    2017-07-26

    In this study, porous manganese oxide (MnO x ) thin films were synthesized via electrostatic spray deposition (ESD) and evaluated as pseudocapacitive electrode materials in neutral aqueous media. Very interestingly, the gravimetric specific capacitance of the ESD-based electrodes underwent a marked enhancement upon electrochemical cycling, from 72 F∙g -1 to 225 F∙g -1 , with a concomitant improvement in kinetics and conductivity. The change in capacitance and resistivity is attributed to a partial electrochemical phase transformation from the spinel-type hausmannite Mn₃O₄ to the conducting layered birnessite MnO₂. Furthermore, the films were able to retain 88.4% of the maximal capacitance after 1000 cycles. Upon verifying the viability of the manganese oxide films for pseudocapacitive applications, the thin films were integrated onto carbon micro-pillars created via carbon microelectromechanical systems (C-MEMS) for examining their application as potential microelectrode candidates. In a symmetric two-electrode cell setup, the MnO x /C-MEMS microelectrodes were able to deliver specific capacitances as high as 0.055 F∙cm -2 and stack capacitances as high as 7.4 F·cm -3 , with maximal stack energy and power densities of 0.51 mWh·cm -3 and 28.3 mW·cm -3 , respectively. The excellent areal capacitance of the MnO x -MEs is attributed to the pseudocapacitive MnO x as well as the three-dimensional architectural framework provided by the carbon micro-pillars.

  2. Electrostatic Spray Deposition-Based Manganese Oxide Films—From Pseudocapacitive Charge Storage Materials to Three-Dimensional Microelectrode Integrands

    Directory of Open Access Journals (Sweden)

    Richa Agrawal

    2017-07-01

    Full Text Available In this study, porous manganese oxide (MnOx thin films were synthesized via electrostatic spray deposition (ESD and evaluated as pseudocapacitive electrode materials in neutral aqueous media. Very interestingly, the gravimetric specific capacitance of the ESD-based electrodes underwent a marked enhancement upon electrochemical cycling, from 72 F∙g−1 to 225 F∙g−1, with a concomitant improvement in kinetics and conductivity. The change in capacitance and resistivity is attributed to a partial electrochemical phase transformation from the spinel-type hausmannite Mn3O4 to the conducting layered birnessite MnO2. Furthermore, the films were able to retain 88.4% of the maximal capacitance after 1000 cycles. Upon verifying the viability of the manganese oxide films for pseudocapacitive applications, the thin films were integrated onto carbon micro-pillars created via carbon microelectromechanical systems (C-MEMS for examining their application as potential microelectrode candidates. In a symmetric two-electrode cell setup, the MnOx/C-MEMS microelectrodes were able to deliver specific capacitances as high as 0.055 F∙cm−2 and stack capacitances as high as 7.4 F·cm−3, with maximal stack energy and power densities of 0.51 mWh·cm−3 and 28.3 mW·cm−3, respectively. The excellent areal capacitance of the MnOx-MEs is attributed to the pseudocapacitive MnOx as well as the three-dimensional architectural framework provided by the carbon micro-pillars.

  3. Cross Entropy Measures of Bipolar and Interval Bipolar Neutrosophic Sets and Their Application for Multi-Attribute Decision-Making

    Directory of Open Access Journals (Sweden)

    Surapati Pramanik

    2018-03-01

    Full Text Available The bipolar neutrosophic set is an important extension of the bipolar fuzzy set. The bipolar neutrosophic set is a hybridization of the bipolar fuzzy set and neutrosophic set. Every element of a bipolar neutrosophic set consists of three independent positive membership functions and three independent negative membership functions. In this paper, we develop cross entropy measures of bipolar neutrosophic sets and prove their basic properties. We also define cross entropy measures of interval bipolar neutrosophic sets and prove their basic properties. Thereafter, we develop two novel multi-attribute decision-making strategies based on the proposed cross entropy measures. In the decision-making framework, we calculate the weighted cross entropy measures between each alternative and the ideal alternative to rank the alternatives and choose the best one. We solve two illustrative examples of multi-attribute decision-making problems and compare the obtained result with the results of other existing strategies to show the applicability and effectiveness of the developed strategies. At the end, the main conclusion and future scope of research are summarized.

  4. Progranulin gene variability influences the risk for bipolar I disorder, but not bipolar II disorder.

    Science.gov (United States)

    Galimberti, Daniela; Prunas, Cecilia; Paoli, Riccardo A; Dell'Osso, Bernardo; Fenoglio, Chiara; Villa, Chiara; Palazzo, Carlotta; Cigliobianco, Michela; Camuri, Giulia; Serpente, Maria; Scarpini, Elio; Altamura, A Carlo

    2014-11-01

    Recent data have shown that genetic variability in the progranulin (GRN) gene may contribute to the susceptibility to developing bipolar disorder (BD). However, in regard to patients with BD, no information is available on the role of genetic variability and plasma progranulin levels in different types of this disorder. In this study, we performed an association analysis of GRN in an Italian population consisting of 134 patients with BD and 232 controls to evaluate progranulin plasma levels. The presence of the polymorphic variant of the rs5848 single nucleotide polymorphism is protective for the development of bipolar I disorder (BD-I) (odds ratio = 0.55, 95% confidence interval: 0.33-0.93; p = 0.024) but not bipolar II disorder (BD-II) (p > 0.05). In addition, plasma progranulin levels are significantly decreased in BD [mean ± standard deviation (SD) 112 ± 35 versus 183 ± 93 ng/mL in controls; p < 0.001]. Regarding the influence of GRN variability on BD susceptibility, the predisposing genetic background differs between BD-I and BD-II, possibly implying that pathogenic mechanisms differ between the two subtypes of BD. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  5. Toward a complex system understanding of bipolar disorder: A chaotic model of abnormal circadian activity rhythms in euthymic bipolar disorder.

    Science.gov (United States)

    Hadaeghi, Fatemeh; Hashemi Golpayegani, Mohammad Reza; Jafari, Sajad; Murray, Greg

    2016-08-01

    In the absence of a comprehensive neural model to explain the underlying mechanisms of disturbed circadian function in bipolar disorder, mathematical modeling is a helpful tool. Here, circadian activity as a response to exogenous daily cycles is proposed to be the product of interactions between neuronal networks in cortical (cognitive processing) and subcortical (pacemaker) areas of the brain. To investigate the dynamical aspects of the link between disturbed circadian activity rhythms and abnormalities of neurotransmitter functioning in frontal areas of the brain, we developed a novel mathematical model of a chaotic system which represents fluctuations in circadian activity in bipolar disorder as changes in the model's parameters. A novel map-based chaotic system was developed to capture disturbances in circadian activity across the two extreme mood states of bipolar disorder. The model uses chaos theory to characterize interplay between neurotransmitter functions and rhythm generation; it aims to illuminate key activity phenomenology in bipolar disorder, including prolonged sleep intervals, decreased total activity and attenuated amplitude of the diurnal activity rhythm. To test our new cortical-circadian mathematical model of bipolar disorder, we utilized previously collected locomotor activity data recorded from normal subjects and bipolar patients by wrist-worn actigraphs. All control parameters in the proposed model have an important role in replicating the different aspects of circadian activity rhythm generation in the brain. The model can successfully replicate deviations in sleep/wake time intervals corresponding to manic and depressive episodes of bipolar disorder, in which one of the excitatory or inhibitory pathways is abnormally dominant. Although neuroimaging research has strongly implicated a reciprocal interaction between cortical and subcortical regions as pathogenic in bipolar disorder, this is the first model to mathematically represent this

  6. A report on older-age bipolar disorder from the International Society for Bipolar Disorders Task Force

    DEFF Research Database (Denmark)

    Sajatovic, Martha; Strejilevich, Sergio A; Gildengers, Ariel G

    2015-01-01

    , and shed light on issues of relevance to BD research across the lifespan. Although there is still a dearth of research and health efforts focused on older adults with BD, emerging data have brought some answers, innovative questions, and novel perspectives related to the notion of late onset, medical......OBJECTIVES: In the coming generation, older adults with bipolar disorder (BD) will increase in absolute numbers as well as proportion of the general population. This is the first report of the International Society for Bipolar Disorder (ISBD) Task Force on Older-Age Bipolar Disorder (OABD). METHODS...

  7. Bipolar nickel-hydrogen battery design

    Science.gov (United States)

    Koehler, C. W.; Applewhite, A. Z.; Kuo, Y.

    1985-01-01

    The initial design for the NASA-Lewis advanced nickel-hydrogen battery is discussed. Fabrication of two 10-cell boilerplate battery stacks will soon begin. The test batteries will undergo characterization testing and low Earth orbit life cycling. The design effectively deals with waste heat generated in the cell stack. Stack temperatures and temperature gradients are maintained to acceptable limits by utilizing the bipolar conduction plate as a heat path to the active cooling fluid panel external to the edge of the cell stack. The thermal design and mechanical design of the battery stack together maintain a materials balance within the cell. An electrolyte seal on each cell frame prohibits electrolyte bridging. An oxygen recombination site and electrolyte reservoir/separator design does not allow oxygen to leave the cell in which it was generated.

  8. [Everyday stress, routines and bipolar spectrum].

    Science.gov (United States)

    Gindre, C; Swendsen, J

    2010-06-01

    Bipolar patients relapse more frequently under conditions of stress, even when compliant with prescribed medication. Although the biological bases of stress reactivity remain widely debated, the disruption of biological or circadian rhythms has been suggested as one possible mechanism through which stress increases the risk of episodes. This hypothesis has gained support from recent evidence demonstrating that the disruption of social rhythms is particularly implicated in the onset of manic episodes. However, it is currently unknown to what extent bipolar patients may differ from normal controls in terms of the basic prevalence and nature of daily life routines, or if such individuals are more sensitive to the disruption of such rhythms following exposure to stress. Using a dimensional perspective of bipolar disorder, 1728 French university students were first screened concerning diverse psychological and clinical characteristics. Two hundred and twelve individuals at high or low-risk for mood and substance use disorders were then invited to participate in a week-long period of ambulatory monitoring using the experience sampling method (ESM). During this phase, participants were given a preprogrammed PDA microcomputer which provided ambulatory assessments of behaviour and stress at fixed intervals (randomized across participants). At the end of the ESM phase, the microcomputers were collected and structured diagnostic interviews were administered to each participant. For the purposes of the current study, analyses focused on a subsample of 92 individuals, reflecting the 28 participants who met lifetime criteria for a manic (n=15) or hypomanic episode (n=13), and the 64 individuals who were free of any lifetime disorder. Data were analyzed using hierarchical nonlinear (Bernoulli) models for repeated measures. Covariates included age, sex, frequency of substance use and cognitive vulnerabilities assessed at screening. A Bonferroni correction was applied to adjust

  9. HTC: May survive in bipolar world

    Directory of Open Access Journals (Sweden)

    Singh Netra Pal

    2016-01-01

    Full Text Available The core assets of HTC are people, innovations, and technology. But in the recent quarters, HTC has started retrenching people even from R&D divisions which are responsible for innovation and developing new technologies. It means HTC's core assets are depleting. HTC was known for its cutting edge technology of 16mp camera and high speed '4G' technology but performing badly in the last two and half year. Why is it so? Paper objectives are to identify reasons for its downfall of HTC, distress signals for HTC downfall, and possible revival strategies for survival of HTC in Bipolar world (Samsung and Apple of smartphones makers. In addition, research paper present eight research proposition/ questions with respect to present state of HTC and its future and possible answers to these research propositions/ questions. Research paper ends with concluding remarks in the context of HTC future.

  10. Posttraumatic stress disorder and bipolar mood disorder

    OpenAIRE

    Machado Vieira, Rodrigo; Gauer, Gabriel J C

    2003-01-01

    O Transtorno Bipolar (THB) não é somente uma condição endógena. Severos eventos negativos durante a vida influenciam o desenvolvimento do primeiro episódio e alteram o curso do THB durante a vida. O Transtorno de Estresse Pós-Traumático (TEPT) é uma severa e incapacitante doença mental que afeta uma significativa parcela da população, em algum momento de suas vidas. A presença concomitante de TEPT e THB parece mais freqüente que anteriormente sugerido, e pacientes psicóticos com história de t...

  11. [Disease mongering and bipolar disorder in Japan].

    Science.gov (United States)

    Ihara, Hiroshi

    2011-01-01

    ,600 in 2003. At the same time, antidepressant sales have sextupled, from\\14.5 billion in 1998 to\\87 billion in 2006, according to statistics from GlaxoSmithKline. Recently, the pharmaceutical industry has shifted its focus from depression to bipolar disorder. Historically, Japanese psychiatrists have been familiar with Emil Kraepelin's "manic depressive insanity" (1899), whose definition was much narrower than that of its contemporary counterpart, bipolar disorder. Thus far, perhaps due partly to the reference in Kraepelin's definition of "manic depressive" disorder, Japanese psychiatrists have rather conservatively prescribed mood stabilizers for persons with frequent mood swings. Japanese psychiatrists can learn a great deal from their experience with the aggressive marketing of antidepressants. In the case of depression, over-medication arguably did more harm than good. The same risk exists with bipolar disorder. Disease mongering may occur whenever the interests of a pharmaceutical company exceed the expected benefits from the proposed pharmacotherapy on those affected by the putative bipolar disorder. In cases that are not severe enough for aggressive medication, psychiatrists should propose natural alternatives, such as an alteration of lifestyle and psychotherapy.

  12. Compliance to treatment in bipolar disorder

    OpenAIRE

    Santin, Aida; Ceresér, Keila; Rosa, Adriane

    2005-01-01

    O transtorno bipolar (TB) é uma doença crônica, recorrente, presente em 1,5% da população, estando associada a altas taxas de mortalidade e prejuízos socioeconômicos. O lítio, a carbamazepina e o ácido valpróico são os estabilizadores de humor mais usados. Em tratamentos prolongados, como é o caso do TB, a má-adesão dos pacientes é uma das maiores dificuldades. Verifica-se que fatores ligados ao paciente, aos medicamentos e aos médicos possam ser responsáveis pela baixa adesão. A psicoeducaçã...

  13. Autoamputation of Genitalia in Bipolar Patient

    Directory of Open Access Journals (Sweden)

    Vinod Sharma

    2017-01-01

    Full Text Available According to literature, genital self-mutilation (GSM is more commonly associated with psychosis as compared with self-mutilation as a whole. There have been many case reports of GSM in psychotic disorders. We describe herein a case of a Caucasian, employed, and married male suffering from bipolar disorder type II with history of self-mutilating behavior, who amputated his penis during symptom-free phase of his illness. Several features are reflected as risky elements for genital self-mutilation, for example, homosexual and transsexual tendencies, abandonment of the male genitals, lack of competent male for identification during childhood, feeling of guilt for sexual offences, and self-injuries in anamnesis. This report will highlight various factors responsible for self-mutilation in nonpsychotic and nondelusional person.

  14. Relato de caso: transtorno afetivo bipolar

    OpenAIRE

    Carlos Von Krakauer Hübner; Edson Vinicius Milanello; Maria Fernanda Moro Barbieri; Marcelo Ricardo de Oliveira Barcelos; Lucas Augusto Ayres Ribas

    2016-01-01

    Introdução: O transtorno afetivo bipolar (TAB) é uma doença crônica e grave, marcada pela variância de episódios depressivos com episódios de mania ou hipomania, podendo haver sintomas psicóticos. É classificado em dois tipos, I e II. Sua etiologia é desconhecida, mas supõe-se que envolva influências genéticas e ambientais, variando a cada indivíduo afetado. As apresentações clínicas do TAB podem variar de episódios leves de depressão ou hipomania até episódios depressivos graves ou mania aco...

  15. Cognitive enhancement treatments for bipolar disorder

    DEFF Research Database (Denmark)

    Miskowiak, Kamilla W; Carvalho, André F; Vieta, Eduard

    2016-01-01

    Cognitive dysfunction is an emerging treatment target in bipolar disorder (BD). Several trials have assessed the efficacy of novel pharmacological and psychological treatments on cognition in BD but the findings are contradictory and unclear. A systematic search following the PRISMA guidelines...... was conducted on PubMed and PsychInfo. Eligible articles reported randomized, controlled or open-label trials investigating pharmacological or psychological treatments targeting cognitive dysfunction in BD. The quality of the identified randomized controlled trials (RCTs) was evaluated with the Cochrane...... Collaboration's Risk of Bias tool. We identified 19 eligible studies of which 13 were RCTs and six were open-label or non-randomized studies. The findings regarding efficacy on cognition were overall disappointing or preliminary, possibly due to several methodological challenges. For the RCTs, the risk of bias...

  16. Sexual behavior in women with bipolar disorder.

    Science.gov (United States)

    Mazza, Marianna; Harnic, Desiree; Catalano, Valeria; Di Nicola, Marco; Bruschi, Angelo; Bria, Pietro; Daniele, Antonio; Mazza, Salvatore

    2011-06-01

    There is a lack of studies regarding sexuality and sexual behavior in women with bipolar disorder. The aim of this study is to investigate sexual behavior in women affected by bipolar disorder in order to stimulate interest and debate in this area of care. Sixty women (30 BD I and 30 BD II) consent to participate in the study and were included in the sample. Moreover, sixty female healthy subjects without histories of psychiatric disorders were recruited as normal controls. Patients and healthy subjects were given the Sexual Interest and Sexual Performance Questionnaire, a questionnaire devised to explore various aspects of sexual behavior. The results of the present study suggest an increase of sexual interest in patients with BD I as compared both with BD II patients and healthy controls. In women with BD I such increase of interest was detected on some items of section I of the Sexual Interest and Sexual Performance Questionnaire, in particular "Actual Value of Sexuality" and "Implicit Sexual Interest", which implicitly explore sexual interest without overtly focusing upon sexual problems. Moreover, we observed a higher desired frequency of intercourse in women with BD I than BD II and a higher occurrence of repeated sexual intercourse in women with BD I than BD II. The main finding of the present study was an increase of sexual interest in BD I as compared with BD II female patients and normal controls. This result was detected when sexual interest was explored implicitly. Our study is limited by the small size of our subject groups. Further investigations on larger subject samples are needed to better clarify particular aspects of sexual behavior of BD patients. Copyright © 2010 Elsevier B.V. All rights reserved.

  17. Impaired recognition of happy facial expressions in bipolar disorder.

    Science.gov (United States)

    Lawlor-Savage, Linette; Sponheim, Scott R; Goghari, Vina M

    2014-08-01

    The ability to accurately judge facial expressions is important in social interactions. Individuals with bipolar disorder have been found to be impaired in emotion recognition; however, the specifics of the impairment are unclear. This study investigated whether facial emotion recognition difficulties in bipolar disorder reflect general cognitive, or emotion-specific, impairments. Impairment in the recognition of particular emotions and the role of processing speed in facial emotion recognition were also investigated. Clinically stable bipolar patients (n = 17) and healthy controls (n = 50) judged five facial expressions in two presentation types, time-limited and self-paced. An age recognition condition was used as an experimental control. Bipolar patients' overall facial recognition ability was unimpaired. However, patients' specific ability to judge happy expressions under time constraints was impaired. Findings suggest a deficit in happy emotion recognition impacted by processing speed. Given the limited sample size, further investigation with a larger patient sample is warranted.

  18. Combinations of SNPs Related to Signal Transduction in Bipolar Disorder

    DEFF Research Database (Denmark)

    Koefoed, Pernille; Andreassen, Ole A; Bennike, Bente

    2011-01-01

    of complex diseases, it may be useful to look at combinations of genotypes. Genes related to signal transmission, e.g., ion channel genes, may be of interest in this respect in the context of bipolar disorder. In the present study, we analysed 803 SNPs in 55 genes related to aspects of signal transmission...... and calculated all combinations of three genotypes from the 3×803 SNP genotypes for 1355 controls and 607 patients with bipolar disorder. Four clusters of patient-specific combinations were identified. Permutation tests indicated that some of these combinations might be related to bipolar disorder. The WTCCC...... in the clusters in the two datasets. The present analyses of the combinations of SNP genotypes support a role for both genetic heterogeneity and interactions in the genetic architecture of bipolar disorder....

  19. Voice analysis as an objective state marker in bipolar disorder

    DEFF Research Database (Denmark)

    Faurholt-Jepsen, M.; Busk, Jonas; Frost, M.

    2016-01-01

    Changes in speech have been suggested as sensitive and valid measures of depression and mania in bipolar disorder. The present study aimed at investigating (1) voice features collected during phone calls as objective markers of affective states in bipolar disorder and (2) if combining voice...... features, automatically generated objective smartphone data on behavioral activities and electronic self-monitored data were collected from 28 outpatients with bipolar disorder in naturalistic settings on a daily basis during a period of 12 weeks. Depressive and manic symptoms were assessed using...... and electronic self-monitored data increased the accuracy, sensitivity and specificity of classification of affective states slightly. Voice features collected in naturalistic settings using smartphones may be used as objective state markers in patients with bipolar disorder....

  20. Do young adults with bipolar disorder benefit from early intervention?

    DEFF Research Database (Denmark)

    Kessing, Lars Vedel; Hansen, Hanne Vibe; Christensen, Ellen Margrethe

    2014-01-01

    BACKGROUND: It is unknown whether young adults with bipolar disorder are able to benefit from early intervention combining optimised pharmacological treatment and group psychoeducation. The aim of the present report was to compare the effects of early intervention among patients with bipolar...... disorder aged 18-25 years to that of patients aged 26 years or older. METHODS: Patients were randomised to early treatment in a specialised outpatient mood disorder clinic versus standard care. The primary outcome was risk of psychiatric re-hospitalisation. RESULTS: A total of 158 patients with mania/bipolar...... different, the observed differences of the point estimates was surprisingly larger for young adults suggesting that young adults with bipolar disorder may benefit even more than older adults from early intervention combining pharmacological treatment and group psychoeducation....

  1. Mortality and secular trend in the incidence of bipolar disorder

    DEFF Research Database (Denmark)

    Medici, Clara Reece; Videbech, Poul; Gustafsson, Lea Nørgreen

    2015-01-01

    BACKGROUND: The world-wide interest in bipolar disorder is illustrated by an exponential increase in publications on the disorder registered in Pubmed since 1990. This inspired an investigation of the epidemiology of bipolar disorder. METHODS: This was a register-based cohort study. All first......-ever diagnoses of bipolar disorder (International Classification of Diseases-10: F31) were identified in the nationwide Danish Psychiatric Central Research Register between 1995 and 2012. Causes of death were obtained from The Danish Register of Causes of Death. Age- and gender standardized incidence rates......, standardized mortality ratio (SMR) and Kaplan-Meier survival estimates were calculated. RESULTS: We identified 15,334 incident cases of bipolar disorder. The incidence rate increased from 18.5/100,000 person-years (PY) in 1995 to 28.4/100,000 PY in 2012. The mean age at time of diagnosis decreased...

  2. Increased risk of hyperthyroidism among patients hospitalized with bipolar disorder

    DEFF Research Database (Denmark)

    Thomsen, Anders F; Kessing, Lars V

    2005-01-01

    OBJECTIVES: Hyperthyroidism has been associated with affective disorder in many cross-sectional studies, but longitudinal studies in this connection are scarce. We assessed whether hospitalization with depressive disorder or bipolar disorder was a risk factor for development of hyperthyroidism....... METHODS: We conducted a historical cohort study using the Danish register data. The observational period was 1977--99. Three study cohorts were identified: all patients with a first hospital admission with resulting index discharge diagnoses of depression, bipolar disorder, or osteoarthritis. The risks...... with depressive disorder did not have an increased risk of hyperthyroidism, whereas patients with bipolar disorder had an increased of risk on the margin of statistical significance, when compared to patients with osteoarthritis. Patients with bipolar disorder had a significantly increased risk of hyperthyroidism...

  3. Cognitive Impairment in Bipolar Disorder: Treatment and Prevention Strategies.

    Science.gov (United States)

    Solé, Brisa; Jiménez, Esther; Torrent, Carla; Reinares, Maria; Bonnin, Caterina Del Mar; Torres, Imma; Varo, Cristina; Grande, Iria; Valls, Elia; Salagre, Estela; Sanchez-Moreno, Jose; Martinez-Aran, Anabel; Carvalho, André F; Vieta, Eduard

    2017-08-01

    Over the last decade, there has been a growing appreciation of the importance of identifying and treating cognitive impairment associated with bipolar disorder, since it persists in remission periods. Evidence indicates that neurocognitive dysfunction may significantly influence patients' psychosocial outcomes. An ever-increasing body of research seeks to achieve a better understanding of potential moderators contributing to cognitive impairment in bipolar disorder in order to develop prevention strategies and effective treatments. This review provides an overview of the available data from studies examining treatments for cognitive dysfunction in bipolar disorder as well as potential novel treatments, from both pharmacological and psychological perspectives. All these data encourage the development of further studies to find effective strategies to prevent and treat cognitive impairment associated with bipolar disorder. These efforts may ultimately lead to an improvement of psychosocial functioning in these patients. © The Author 2017. Published by Oxford University Press on behalf of CINP.

  4. Discrete neurocognitive subgroups in fully or partially remitted bipolar disorder

    DEFF Research Database (Denmark)

    Jensen, Johan Høy; Knorr, Ulla; Vinberg, Maj

    2016-01-01

    BACKGROUND: Neurocognitive impairment in remitted patients with bipolar disorder contributes to functional disabilities. However, the pattern and impact of these deficits are unclear. METHODS: We pooled data from 193 fully or partially remitted patients with bipolar disorder and 110 healthy...... controls. Hierarchical cluster analysis was conducted to determine whether there are discrete neurocognitive subgroups in bipolar disorder. The pattern of the cognitive deficits and the characteristics of patients in these neurocognitive subgroups were examined with analyses of covariance and least...... was cross-sectional which limits inferences regarding the causality of the findings. CONCLUSION: Globally and selectively impaired bipolar disorder patients displayed more functional disabilities than those who were cognitively intact. The present findings highlight a clinical need to systematically screen...

  5. Comorbidity of Bipolar Disorder and Multiple Sclerosis: A Case Report

    Directory of Open Access Journals (Sweden)

    Necla Keskin

    2013-08-01

    Full Text Available Multiple sclerosis is a chronic demyelinating disease of a central nervous system. Neuropsychiatric symptoms are common in multiple sclerosis and bipolar disorder is one of the most common psychiatric disorders that coexist with multiple sclerosis. Manic episodes may be the first presenting symptom of multiple sclerosis as comorbid pathology or as an adverse effect of pharmacotherapies used in multiple sclerosis. The comorbidity of bipolar disorder and multiple sclerosis is well-proven but its etiology is not known and investigated accurately. Recent studies support a common genetic susceptibility. Management of bipolar disorder in multiple sclerosis is based on evidence provided by case reports and treatment should be individualized. In this report, the association between bipolar disorder and multiple sclerosis, epidemiology, ethiology and treatment is discussed through a case had diagnosed as multiple sclerosis and had a manic episode with psychotic features. [Cukurova Med J 2013; 38(4.000: 832-836

  6. GANGGUAN AFEKTIF BIPOLAR MANIA DENGAN PSIKOTIK: SEBUAH LAPORAN KASUS

    Directory of Open Access Journals (Sweden)

    Hendrikus Gede Surya Adhi Putra

    2015-05-01

    Full Text Available Gangguan bipolar merupakan gangguan yang terdiri dari afek yang meningkat, dan jugaaktivitas yang berlebih (mania atau hipomania, dan dalam jangka waktu yang berbedaterjadi penurunan afek yang disertai dengan penurunan aktivitas (depresi. Kejadianpada  gangguan  bipolar  berkisar  antara  0,3-1,5%.  Prevalensi  serupa  pada  pria  danwanita.Gejala gangguan bipolar episode manik meliputi perasaan sensitif, kurangistirahat, harga diri melonjak naik, dan pada episode depresi meliputi kehilanganminat, tidur lebih atau kurang dari normal, gelisah, merasa tidak berharga, dan kurangkonsentrasi. Laporan ini membahas kasus gangguan bipolar episode kini manik yangterjadi pada seorang laki-laki berusia 45 tahun. Pasien ini mendapatkan psikoterapi,haloperidol 1 x 5 mg, dan trihexyphenidyl 1 x 2 mg per oral.

  7. Cognitive Impairment in Bipolar Disorder: Treatment and Prevention Strategies

    Science.gov (United States)

    Solé, Brisa; Jiménez, Esther; Torrent, Carla; Reinares, Maria; Bonnin, Caterina del Mar; Torres, Imma; Varo, Cristina; Grande, Iria; Valls, Elia; Salagre, Estela; Sanchez-Moreno, Jose; Martinez-Aran, Anabel; Carvalho, André F

    2017-01-01

    Abstract Over the last decade, there has been a growing appreciation of the importance of identifying and treating cognitive impairment associated with bipolar disorder, since it persists in remission periods. Evidence indicates that neurocognitive dysfunction may significantly influence patients’ psychosocial outcomes. An ever-increasing body of research seeks to achieve a better understanding of potential moderators contributing to cognitive impairment in bipolar disorder in order to develop prevention strategies and effective treatments. This review provides an overview of the available data from studies examining treatments for cognitive dysfunction in bipolar disorder as well as potential novel treatments, from both pharmacological and psychological perspectives. All these data encourage the development of further studies to find effective strategies to prevent and treat cognitive impairment associated with bipolar disorder. These efforts may ultimately lead to an improvement of psychosocial functioning in these patients. PMID:28498954

  8. The continuum between Bipolar Disorder and Borderline Personality Disorder.

    Science.gov (United States)

    Elisei, Sandro; Anastasi, Serena; Verdolini, Norma

    2012-09-01

    Several studies have been carried out regarding the possible overlap between Bipolar Disorder and borderline personality disorder. Up to now, it is not possible to provide a definitive picture. In fact, there is currently significant debate about the relationship between Borderline Personality Disorder and Bipolar Disorder. MEDLINE searches were performed to identify the latest studies of these disorders, considering psychodynamic aspects. Bipolar disorder and borderline personality disorder share common clinical features, namely affective instability and impulsivity which however differ in quality. Consequently, to better understand these aspects, it is necessary to trace the stages of childhood psychological development. It has been claimed that Bipolar Disorder Type II can be divided into two subtypes: one stable and functional between episodes and one unstable between episodes which is related to Borderline Personality Disorder. However, better diagnostic theories, psychiatrist's empathy and patience remain the essential tool to understand and to face human suffering.

  9. Quality of web-based information on bipolar disorder.

    Science.gov (United States)

    Morel, Vincent; Chatton, Anne; Cochand, Sophie; Zullino, Daniele; Khazaal, Yasser

    2008-10-01

    To evaluate web-based information on bipolar disorder and to assess particular content quality indicators. Two keywords, "bipolar disorder" and "manic depressive illness" were entered into popular World Wide Web search engines. Websites were assessed with a standardized proforma designed to rate sites on the basis of accountability, presentation, interactivity, readability and content quality. "Health on the Net" (HON) quality label, and DISCERN scale scores were used to verify their efficiency as quality indicators. Of the 80 websites identified, 34 were included. Based on outcome measures, the content quality of the sites turned-out to be good. Content quality of web sites dealing with bipolar disorder is significantly explained by readability, accountability and interactivity as well as a global score. The overall content quality of the studied bipolar disorder websites is good.

  10. The role of estrogen in bipolar disorder, a review

    DEFF Research Database (Denmark)

    Meinhard, Ninja; Kessing, Lars Vedel; Vinberg, Maj

    2014-01-01

    hormones, e.g. estrogen, are fluctuating and particularly postpartum there is a steep fall in the levels of serum estrogen. The role of estrogen in women with bipolar disorder is, however, not fully understood. Aim: The main objective of this review is to evaluate the possible relation between serum...... estrogen levels and women with bipolar disorder including studies of the anti manic effects of the selective estrogen receptor modulator tamoxifen. Method: A systematically literature search on PubMed was conducted: two studies regarding the connection between serum estrogen levels and women with bipolar...... tamoxifen studies found that tamoxifen was effective in producing antimanic effects. Conclusion: These results indicate that estrogen fluctuations may be an important factor in the etiology of bipolar disorder and it is obvious that more research on this topic is needed to clarify the role of estrogen...

  11. The role of estrogen in bipolar disorder, a review

    DEFF Research Database (Denmark)

    Meinhard, Ninja; Kessing, Lars Vedel; Vinberg, Maj

    2014-01-01

    hormones, e.g. estrogen, are fluctuating and particularly postpartum there is a steep fall in the levels of serum estrogen. The role of estrogen in women with bipolar disorder is, however, not fully understood. AIM: The main objective of this review is to evaluate the possible relation between serum...... estrogen levels and women with bipolar disorder including studies of the anti manic effects of the selective estrogen receptor modulator tamoxifen. METHOD: A systematically literature search on PubMed was conducted: two studies regarding the connection between serum estrogen levels and women with bipolar...... tamoxifen studies found that tamoxifen was effective in producing antimanic effects. CONCLUSION: These results indicate that estrogen fluctuations may be an important factor in the etiology of bipolar disorder and it is obvious that more research on this topic is needed to clarify the role of estrogen...

  12. Towards a blood-based diagnostic panel for bipolar disorder

    NARCIS (Netherlands)

    F. Haenisch (Frieder); J.D. Cooper (Jason); A. Reif (Andreas); S. Kittel-Schneider (Sarah); J. Steiner (Johann); F.M. Leweke (Marcus); M. Rothermundt (Matthias); N.J.M. van Beveren (Nico); B. Crespo-Facorro (Benedicto); D. Niebuhr (David); D. Cowan (David); N. Weber (Natalya); R.H. Yolken (Robert); B.W.J.H. Penninx (Brenda W.J.H.); S. Bahn (Sabine)

    2015-01-01

    markdownabstract_Background:_ Bipolar disorder (BD) is a costly, devastating and life shortening mental disorder that is often misdiagnosed, especially on initial presentation. Misdiagnosis frequently results in ineffective treatment. We investigated the utility of a biomarker panel as a diagnostic

  13. The Dysregulated Brain : A psychoimmunological approach to bipolar disorder

    NARCIS (Netherlands)

    Haarman, Bartholomeus Cornelius Maria

    2017-01-01

    An important problem with psychiatric disorders is that much remains unknown about the underlying disease mechanisms, thereby delaying sometimes for many years the diagnosis bipolar disorder, with significant implications for treatment. In recent years, the neuroinflammation theory, which assumes

  14. Attention deficit hyperactivity disorder and bipolar mood disorder in ...

    African Journals Online (AJOL)

    2009-06-19

    Jun 19, 2009 ... Bipolar mood disorder (BMD) has traditionally been seen as an adult disorder and .... antisocial behaviour, such as conduct disorder.3. In young ... In personality structure and temperament, children with BMD are more likely to ...

  15. State-related alterations of gene expression in bipolar disorder

    DEFF Research Database (Denmark)

    Munkholm, Klaus; Vinberg, Maj; Berk, Michael

    2012-01-01

    Munkholm K, Vinberg M, Berk M, Kessing LV. State-related alterations of gene expression in bipolar disorder: a systematic review. Bipolar Disord 2012: 14: 684-696. © 2012 The Authors. Journal compilation © 2012 John Wiley & Sons A/S. Objective:  Alterations in gene expression in bipolar disorder...... have been found in numerous studies. It is unclear whether such alterations are related to specific mood states. As a biphasic disorder, mood state-related alterations in gene expression have the potential to point to markers of disease activity, and trait-related alterations might indicate...... vulnerability pathways. This review therefore evaluated the evidence for whether gene expression in bipolar disorder is state or trait related. Methods:  A systematic review, using the Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) guideline for reporting systematic reviews, based...

  16. International Society for Bipolar Disorders Task Force on Suicide

    DEFF Research Database (Denmark)

    Schaffer, Ayal; Isometsä, Erkki T; Tondo, Leonardo

    2015-01-01

    significantly associated with suicide attempts were: female gender, younger age at illness onset, depressive polarity of first illness episode, depressive polarity of current or most recent episode, comorbid anxiety disorder, any comorbid substance use disorder, alcohol use disorder, any illicit substance use......OBJECTIVES: Bipolar disorder is associated with a high risk of suicide attempts and suicide death. The main objective of the present study was to identify and quantify the demographic and clinical correlates of attempted and completed suicide in people with bipolar disorder. METHODS: Within...... the framework of the International Society for Bipolar Disorders Task Force on Suicide, a systematic review of articles published since 1980, characterized by the key terms bipolar disorder and 'suicide attempts' or 'suicide', was conducted, and data extracted for analysis from all eligible articles...

  17. Urbanicity during upbringing and bipolar affective disorders in Denmark

    DEFF Research Database (Denmark)

    Pedersen, Carsten Bøcker; Mortensen, Preben Bo

    2006-01-01

    It has been suggested that known or suspected risk factors for schizophrenia may also be of importance for other psychoses, but the empirical evidence regarding this is limited. Urbanicity of place of birth and during upbringing has been shown to be related to the risk of schizophrenia. Few studies...... of urbanicity in relation to bipolar affective disorder exist. Objective: To investigate the potential association between urbanicity at birth and during upbringing and the risk of bipolar affective disorder. Method: Using data from the Danish Civil Registration System, we established a population-based cohort...... of 2.04 million people born in Denmark during 1956-1986, which included information on place of residence during upbringing. Bipolar affective disorder in cohort members was identified by linkage with the Danish Psychiatric Central Register. Results: Overall, 2232 people developed bipolar affective...

  18. Religiosidade e espiritualidade no transtorno bipolar do humor Religiosity and spirituality in bipolar disorder

    Directory of Open Access Journals (Sweden)

    André Stroppa

    2009-01-01

    Full Text Available CONTEXTO: Nos últimos vinte anos, estudos sistematizados têm identificado uma relação positiva entre espiritualidade/religiosidade (R/E e saúde, notadamente saúde mental. Entretanto, são escassas as informações sobre R/E e transtorno bipolar do humor (TBH. Este artigo objetiva revisar as evidências disponíveis sobre estas relações. MÉTODOS: Foram cruzadas as palavras "bipolar", "mania" e "manic" com as palavras "religio*" e "spiritu*" nas bases de dados PubMed e PsychINFO em novembro de 2008. Foram encontrados 122 artigos publicados entre os anos de 1957 e 2008. RESULTADO: Os estudos apontam que pacientes bipolares tendem a apresentar maior envolvimento religioso/espiritual, maior frequência de relatos de conversão e experiências de salvação e uso mais frequente de coping religioso e espiritual (CRE que pessoas com outros transtornos mentais. Indicam ainda, uma relação frequente e significativa entre sintomas maníacos e experiências místicas. Os estudos mais relevantes encontrados na literatura foram agrupados nesta revisão em cinco tópicos: delírios místicos, religiosidade e espiritualidade, coping religioso-espiritual, recursos comunitários e comunidades tradicionais. CONCLUSÃO: O TBH e a R/E possuem intensa e complexa inter-relação. Estudos sobre práticas religiosas saudáveis, espiritualidade e recursos de coping merecem ser ampliados, bem como sua relação com o cumprimento do tratamento e as recorrências da doença, as intervenções psicoterápicas e a psicoeducação de base espiritual.BACKGROUND: Over the past twenty years, systematic studies have identified a positive relationship between spirituality/religiosity (S/R and health, especially mental health. Although there is only scant information about S/R and BipolarDisorder. METHODS: The words "bipolar", "mania" and "manic" were crossed with the words "religio*" and "spiritu*" in the databases PubMed and PsychINFO in November 2008. It was found 122

  19. Composite Bipolar Plate for Unitized Fuel Cell/Electrolyzer Systems

    Science.gov (United States)

    Mittelsteadt, Cortney K.; Braff, William

    2009-01-01

    In a substantial improvement over present alkaline systems, an advanced hybrid bipolar plate for a unitized fuel cell/electrolyzer has been developed. This design, which operates on pure feed streams (H2/O2 and water, respectively) consists of a porous metallic foil filled with a polymer that has very high water transport properties. Combined with a second metallic plate, the pore-filled metallic plates form a bipolar plate with an empty cavity in the center.

  20. Pediatric bipolar disorder: validity, phenomenology, and recommendations for diagnosis

    Science.gov (United States)

    Youngstrom, Eric A; Birmaher, Boris; Findling, Robert L

    2013-01-01

    Objective To find, review, and critically evaluate evidence pertaining to the phenomenology of pediatric bipolar disorder and its validity as a diagnosis. Methods The present qualitative review summarizes and synthesizes available evidence about the phenomenology of bipolar disorder (BD) in youths, including description of the diagnostic sensitivity and specificity of symptoms, clarification about rates of cycling and mixed states, and discussion about chronic versus episodic presentations of mood dysregulation. The validity of the diagnosis of BD in youths is also evaluated based on traditional criteria including associated demographic characteristics, family environmental features, genetic bases, longitudinal studies of youths at risk of developing BD as well as youths already manifesting symptoms on the bipolar spectrum, treatment studies and pharmacologic dissection, neurobiological findings (including morphological and functional data), and other related laboratory findings. Additional sections review impairment and quality of life, personality and temperamental correlates, the clinical utility of a bipolar diagnosis in youths, and the dimensional versus categorical distinction as it applies to mood disorder in youths. Results A schema for diagnosis of BD in youths is developed, including a review of different operational definitions of `bipolar not otherwise specified.' Principal areas of disagreement appear to include the relative role of elated versus irritable mood in assessment, and also the limits of the extent of the bipolar spectrum – when do definitions become so broad that they are no longer describing `bipolar' cases? Conclusions In spite of these areas of disagreement, considerable evidence has amassed supporting the validity of the bipolar diagnosis in children and adolescents. PMID:18199237

  1. Safety and efficacy of quetiapine in bipolar depression.

    Science.gov (United States)

    Bogart, Gregory T; Chavez, Benjamin

    2009-11-01

    To review the clinical data investigating the efficacy and safety of quetiapine in bipolar depression. Searches of MEDLINE and PubMed (1977-July 2009) were conducted using the key words quetiapine and bipolar depression. The references of literature found were cross-referenced. The pharmaceutical company that produces quetiapine was contacted to obtain the posters for the EMBOLDEN I and EMBOLDEN II trials. Only double-blind, placebo-controlled trials were included for review, as well as any subanalyses of the literature that matched this criterion. There was a total of 5 double-blind, placebo-controlled trials and 5 subanalyses reviewed. The results of these data demonstrated quetiapine's efficacy in the treatment of depressive phases of bipolar disorder, including statistically significant improvement in the Montgomery-Asberg Depression Rating Scale (MADRS). In the trials reviewed in this article, the change in MADRS scores ranged from -15.4 to -16.94 within the quetiapine groups, and from -10.26 to -11.93 in the placebo groups. There were also statistically significant improvements in the Hamilton Anxiety Rating Scale, the Short Form of the Quality of Life Enjoyment and Satisfaction Questionnaire, the Pittsburgh Sleep Quality Index, and the Sheehan Disability Scale. All of these trials had a duration of 8 weeks and therefore cannot be applied to the long-term use of quetiapine in bipolar depression. The most common adverse events were sedation, somnolence, and dry mouth. The overall dropout rates for the trials reviewed ranged from 24% to 47%. Based on the literature reviewed here, quetiapine appears to be a safe and efficacious short-term treatment option for bipolar depression. Patients with bipolar type I showed greater improvement on the MADRS than those with bipolar type II. Patients with a rapid-cycling disease course showed an improvement in depressive symptoms, regardless of bipolar type.

  2. Bifurcation analysis of parametrically excited bipolar disorder model

    Science.gov (United States)

    Nana, Laurent

    2009-02-01

    Bipolar II disorder is characterized by alternating hypomanic and major depressive episode. We model the periodic mood variations of a bipolar II patient with a negatively damped harmonic oscillator. The medications administrated to the patient are modeled via a forcing function that is capable of stabilizing the mood variations and of varying their amplitude. We analyze analytically, using perturbation method, the amplitude and stability of limit cycles and check this analysis with numerical simulations.

  3. Revisiting the wandering womb: Oxytocin in endometriosis and bipolar disorder.

    Science.gov (United States)

    Dinsdale, Natalie L; Crespi, Bernard J

    2017-11-01

    Hippocrates attributed women's high emotionality - hysteria - to a 'wandering womb'. Although hysteria diagnoses were abandoned along with the notion that displaced wombs cause emotional disturbance, recent research suggests that elevated levels of oxytocin occur in both bipolar disorder and endometriosis, a gynecological condition involving migration of endometrial tissue beyond the uterus. We propose and evaluate the hypothesis that elevated oxytocinergic system activity jointly contributes to bipolar disorder and endometriosis. First, we provide relevant background on endometriosis and bipolar disorder, and then we examine evidence for comorbidity between these conditions. We next: (1) review oxytocin's associations with personality traits, especially extraversion and openness, and how they overlap with bipolar spectrum traits; (2) describe evidence for higher oxytocinergic activity in both endometriosis and bipolar disorder; (3) examine altered hypothalamic-pituitary-gonadal axis functioning in both conditions; (4) describe data showing that medications that treat one condition can improve symptoms of the other; (5) discuss fitness-related impacts of endometriosis and bipolar disorder; and (6) review a pair of conditions, polycystic ovary syndrome and autism, that show evidence of involving reduced oxytocinergic activity, in direct contrast to endometriosis and bipolar disorder. Considered together, the bipolar spectrum and endometriosis appear to involve dysregulated high extremes of normally adaptive pleiotropy in the female oxytocin system, whereby elevated levels of oxytocinergic activity coordinate outgoing sociality with heightened fertility, apparently characterizing, overall, a faster life history. These findings should prompt a re-examination of how mind-body interactions, and the pleiotropic endocrine systems that underlie them, contribute to health and disease. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Bipolar Disorder in Pregnancy: A Review of Pregnancy Outcomes.

    Science.gov (United States)

    Scrandis, Debra A

    2017-11-01

    Women with bipolar disorder may benefit from continuation of their medications during pregnancy, but there may be risks to the fetus associated with some of these medications. This article examines the evidence relating to the effect of bipolar disorder and pharmacologic treatments for bipolar disorder on pregnancy outcomes. MEDLINE, CINAHL, ProQuest Dissertation & Theses, and the Cochrane Database of Systematic Reviews were searched for English-language studies published between 2000 and 2017, excluding case reports and integrative reviews. Twenty articles that met inclusion criteria were included in this review. Women with bipolar disorder have a higher risk for pregnancy complications and congenital abnormalities than do women without bipolar disorder. In addition, illness relapse can occur if psychotropic medications are discontinued. There are limited data to recommend discontinuing lithium, lamotrigine, or carbamazepine during pregnancy. Valproic acid is not recommended during pregnancy due to increased odds of neural tube defects associated with its use. Atypical antipsychotics are used more frequently during pregnancy, with mixed evidence regarding an association between these agents and congenital malformations or preterm birth. The knowledge of benefits and risks of bipolar disorder and its treatment can help women and health care providers make individualized decisions. Prenatal care providers can discuss the evidence about safety of medications used to treat bipolar disorder with women in collaboration with their mental health care providers. In addition, women being treated for bipolar disorder require close monitoring for depressive and manic/hypomanic episodes that impact pregnancy outcomes. © 2017 by the American College of Nurse-Midwives.

  5. Attention-deficit hyperactivity disorder in bipolar disorder

    OpenAIRE

    Rydén, Eleonore

    2010-01-01

    Attention-deficit hyperactivity disorder (ADHD) is a developmental disorder, i.e., it is by definition present from childhood. The main features characterizing ADHD are the difficulties to regulate attention, activity level, and impulses. The hallmark of bipolar disorder is episodic mood alterations with restitution between episodes. Although debut in childhood may occur, bipolar disorder typically debuts in late adolescence or early adulthood. The overarching aim with this ...

  6. Bipolar resistive switching in different plant and animal proteins

    KAUST Repository

    Bag, A.; Hota, Mrinal Kanti; Mallik, Sandipan B.; Maì ti, Chinmay Kumar

    2014-01-01

    We report bipolar resistive switching phenomena observed in different types of plant and animal proteins. Using protein as the switching medium, resistive switching devices have been fabricated with conducting indium tin oxide (ITO) and Al as bottom and top electrodes, respectively. A clockwise bipolar resistive switching phenomenon is observed in all proteins. It is shown that the resistive switching phenomena originate from the local redox process in the protein and the ion exchange from the top electrode/protein interface.

  7. Relationship between Childhood Maltreatment, Suicidality, and Bipolarity: A Retrospective Study

    OpenAIRE

    Park, Young-Min

    2017-01-01

    Objective The aims of current study were to determine whether childhood maltreatment contributes to the occurrence of major depressive disorder (MDD) with bipolarity or suicidality. Methods In total, 132 outpatients diagnosed with MDD between 2014 and 2015 on the medical records were included. The subjects were divided into two groups according to the presence of childhood maltreatment (CM group) and no childhood maltreatment (NCM group). Depression severity and bipolarity were identified usi...

  8. Connection between Genetic and Clinical Data in Bipolar Disorder

    DEFF Research Database (Denmark)

    Mellerup, Erling; Andreassen, Ole; Bennike, Bente

    2012-01-01

    Complex diseases may be associated with combinations of changes in DNA, where the single change has little impact alone. In a previous study of patients with bipolar disorder and controls combinations of SNP genotypes were analyzed, and four large clusters of combinations were found to be signifi...... to be significantly associated with bipolar disorder. It has now been found that these clusters may be connected to clinical data....

  9. Bipolar resistive switching in different plant and animal proteins

    KAUST Repository

    Bag, A.

    2014-06-01

    We report bipolar resistive switching phenomena observed in different types of plant and animal proteins. Using protein as the switching medium, resistive switching devices have been fabricated with conducting indium tin oxide (ITO) and Al as bottom and top electrodes, respectively. A clockwise bipolar resistive switching phenomenon is observed in all proteins. It is shown that the resistive switching phenomena originate from the local redox process in the protein and the ion exchange from the top electrode/protein interface.

  10. Biocompatibility and characterisation of a candidate microelectrode material for biosensor applications

    International Nuclear Information System (INIS)

    Cyster, L.A.

    2001-10-01

    Recent advances in microcircuit technology have enabled the fabrication of Multiple Microelectrode Arrays (MEAs) for investigating the characteristics of networks of neuronal cells either in vivo or in vitro. When producing a MEA materials used must be corrosion resistant, have low electrical impedance and the materials must be biocompatible. Existing MEA's have limited life spans, relatively high impedance values and limited uses. Thus creating a requirement for new MEA technology. TiN thin films have become increasingly useful in a wide variety of applications, due to their nature, which includes chemical stability, high hardness, excellent wear and electrical properties and also biocompatibility. The favourable electrical and biocompatibility characteristics of thin films of TiN make them a possible candidate for use in a MEA. TiN thin films can be deposited by a number of methods including evaporation, ion plating and sputtering. The method of deposition, along with process parameters used can have a marked effect on the characteristics of TiN films, including changes in preferred orientation, hardness and wear and also biocompatibility. TiN thin films were deposited onto glass substrates by pulsed DC reactive sputtering of a Ti target, with Argon and nitrogen gas mixtures and labelled Type I TiN films. Also industrial TIN films deposited by Arc Ion plating were carefully selected for comparison and labelled Type II TiN films. The microstructure, composition, surface chemistry, surface topography and roughness were studied using X-Ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS), Atomic Force Microscopy (AFM) and Profilometry. Type I TIN films showed a surface topography similar to Zone I and Type II TiN films showed a surface topography similar to Zone 2 of the Movchan and Dernchishin structure zone model for sputtered films. XPS showed that the surface composition of all TiN films was predominantly TiO 2 , TiN and TiN x O y . Significant

  11. Generation of metal composition gradients by means of bipolar electrodeposition

    International Nuclear Information System (INIS)

    Tisserant, Gwendoline; Fattah, Zahra; Ayela, Cédric; Roche, Jérome; Plano, Bernard; Zigah, Dodzi; Goudeau, Bertrand; Kuhn, Alexander; Bouffier, Laurent

    2015-01-01

    Highlights: • A bipolar electrochemistry approach for the preparation of surface gradients is reported. • Several metals are simultaneously deposited on a bipolar electrode. • The elemental composition and thickness of the deposit varies alongside the bipolar electrode. • The deposit affects the surface properties and exhibits a barcode feature. - Abstract: Bipolar electrochemistry is an unconventional technique that currently encounters a renewal of interest due to modern applications in the fields of analytical chemistry or materials science. The approach is particularly relevant for the preparation of asymmetric objects or surfaces such as Janus particles for example. Bipolar electrochemistry allows spatially controlled deposition of various layers from electroactive precursors, selectively at one side of a bipolar electrode. We report here the concomitant cathodic deposition of up to three different metals at the same time in a single experiment. The deposits were characterized by optical and electron microscopy imaging as well as profilometry and energy dispersive X-ray spectroscopy. As a result, the deposited layer is composed of several areas exhibiting both a composition and a thickness gradient. Such a variation directly modifies the optical and electronic properties alongside the surface and gives access to the design of composite surfaces exhibiting a visual gradient feature.

  12. Mapping bipolar worlds: lived geographies of 'madness' in autobiographical accounts.

    Science.gov (United States)

    Chouinard, Vera

    2012-03-01

    This article aims to advance our understanding of women's and men's experiences of negotiating bipolar 'madness' in society and space. It addresses gaps in the clinical literature on life with bipolar and geographic accounts of 'madness' and psycho-emotional distress by considering altered ways of being in place that bipolar 'madness' entails and how narrative sense is made of these. Conceptually, I build on Cosgrove's (2000) approach to psycho-emotional distress and geographic insights about being 'mad' in place. Methodologically and empirically, I draw on thematic narrative analysis of autobiographies of living with bipolar. Key findings include altered paradoxically (dis)embodied ways of being-in-place, 'fractured' or 'whole' senses of self and ways of relating to people/places, 'straddling' 'real' and 'delusional' worlds and bipolar ways of negotiating places are not straightforwardly 'irrational'. While narrative accounts most often invoke dominant discourses about bipolar, sometimes these are challenged through 'rescripting' and 'revaluing mad' identities and ways of being in place. In conclusion, key findings and avenues for future geographical research are discussed. Copyright © 2011 Elsevier Ltd. All rights reserved.

  13. Aberrant cerebellar connectivity in bipolar disorder with psychosis.

    Science.gov (United States)

    Shinn, Ann K; Roh, Youkyung S; Ravichandran, Caitlin T; Baker, Justin T; Öngür, Dost; Cohen, Bruce M

    2017-07-01

    The cerebellum, which modulates affect and cognition in addition to motor functions, may contribute substantially to the pathophysiology of mood and psychotic disorders, such as bipolar disorder. A growing literature points to cerebellar abnormalities in bipolar disorder. However, no studies have investigated the topographic representations of resting state cerebellar networks in bipolar disorder, specifically their functional connectivity to cerebral cortical networks. Using a well-defined cerebral cortical parcellation scheme as functional connectivity seeds, we compared ten cerebellar resting state networks in 49 patients with bipolar disorder and a lifetime history of psychotic features and 55 healthy control participants matched for age, sex, and image signal-to-noise ratio. Patients with psychotic bipolar disorder showed reduced cerebro-cerebellar functional connectivity in somatomotor A, ventral attention, salience, and frontoparietal control A and B networks relative to healthy control participants. These findings were not significantly correlated with current symptoms. Patients with psychotic bipolar disorder showed evidence of cerebro-cerebellar dysconnectivity in selective networks. These disease-related changes were substantial and not explained by medication exposure or substance use. Therefore, they may be mechanistically relevant to the underlying susceptibility to mood dysregulation and psychosis. Cerebellar mechanisms deserve further exploration in psychiatric conditions, and this study's findings may have value in guiding future studies on pathophysiology and treatment of mood and psychotic disorders, in particular.

  14. The functional neuroanatomy of bipolar disorder: a consensus model

    Science.gov (United States)

    Strakowski, Stephen M; Adler, Caleb M; Almeida, Jorge; Altshuler, Lori L; Blumberg, Hilary P; Chang, Kiki D; DelBello, Melissa P; Frangou, Sophia; McIntosh, Andrew; Phillips, Mary L; Sussman, Jessika E; Townsend, Jennifer D

    2013-01-01

    Objectives Functional neuroimaging methods have proliferated in recent years, such that functional magnetic resonance imaging, in particular, is now widely used to study bipolar disorder. However, discrepant findings are common. A workgroup was organized by the Department of Psychiatry, University of Cincinnati (Cincinnati, OH, USA) to develop a consensus functional neuroanatomic model of bipolar I disorder based upon the participants’ work as well as that of others. Methods Representatives from several leading bipolar disorder neuroimaging groups were organized to present an overview of their areas of expertise as well as focused reviews of existing data. The workgroup then developed a consensus model of the functional neuroanatomy of bipolar disorder based upon these data. Results Among the participants, a general consensus emerged that bipolar I disorder arises from abnormalities in the structure and function of key emotional control networks in the human brain. Namely, disruption in early development (e.g., white matter connectivity, prefrontal pruning) within brain networks that modulate emotional behavior leads to decreased connectivity among ventral prefrontal networks and limbic brain regions, especially amygdala. This developmental failure to establish healthy ventral prefrontal–limbic modulation underlies the onset of mania and ultimately, with progressive changes throughout these networks over time and with affective episodes, a bipolar course of illness. Conclusions This model provides a potential substrate to guide future investigations and areas needing additional focus are identified. PMID:22631617

  15. Neurocognition and psychosocial functioning in adolescents with bipolar disorder.

    Science.gov (United States)

    Best, Michael W; Bowie, Christopher R; Naiberg, Melanie R; Newton, Dwight F; Goldstein, Benjamin I

    2017-01-01

    Adults with bipolar disorder demonstrate significantly poorer psychosocial functioning and neurocognition compared to controls. In adult bipolar disorder neurocognition predicts a substantial portion of variance in functioning. Adolescents with bipolar disorder have reducedpsychosocial functioning, but less is known about neurocognitive impairments, and no studies have examined the relationship between neurocognition and functioning in an adolescent sample. 38 adolescents with bipolar disorder and 49 healthy controls under 20 years of age completed assessments of psychosocial functioning, neurocognitive ability, and psychiatric symptoms. Adolescents with bipolar disorder had significantly poorer psychosocial functioning in domains of daily activities, social functioning, and satisfaction with functioning, psadolescent sample with bipolar disorder experiences significantly poorer neurocognitive and psychosocial functioning compared to controls; however, psychosocial functioning appears to be more strongly related to mood symptoms than to neurocognition. Future work is needed to delineate the time course of neurocognitive functioning and its relation to psychosocial functioning across the course of illness. Adolescence may provide an ideal time for cognitive enhancement and intensive psychosocial intervention. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. [Actigraphy in Bipolar Disorder and First Degree Relatives].

    Science.gov (United States)

    Andrade Carrillo, Rommel; Gómez Cano, Sujey; Palacio Ortiz, Juan David; García Valencia, Jenny

    2015-01-01

    Bipolar disorder is a disabling disease that involves a significant economic costs to the health system, making it is essential to investigate possible early predictors such as changes in sleep-wake cycle in high-risk populations. To review the available literature on alterations in the sleep-wake cycle and circadian rhythm in patients with bipolar disorder and their first degree relatives. A literature search was performed in the data bases, Access Medicine, ClinicalKey, EMBASE, JAMA, Lilacs, OVID, Oxford Journals, ScienceDirect, SciELO, APA y PsycNET. Articles in both English and Spanish were reviewed, without limits by study type. Actigraphy is a non-invasive, useful method for assessing sleep-wake cycle disturbances in the active phases of bipolar disorder, and during euthymia periods. Actigraphy showed good sensitivity to predict true sleep, but low specificity, compared with polysomnography. Although studies in bipolar offspring and relatives are scarce, they show sleep changes similar to bipolar patients. Actigraphy may be a good screening tool of sleep/wake cycle in patients with bipolar disorders, because it is economic, non-invasive and sensitive. Longitudinal studies are required to evaluate its potential use as a risk marker. Copyright © 2014 Asociación Colombiana de Psiquiatría. Publicado por Elsevier España. All rights reserved.

  17. Taiwan consensus of pharmacological treatment for bipolar disorder

    Directory of Open Access Journals (Sweden)

    Ya-Mei Bai

    2013-10-01

    Full Text Available Bipolar disorder is an important psychiatric disorder with different disease phases. The pharmacological treatment is complicated, and is updated frequently as new research evidence emerges. For the purpose of international collaboration, research, and education, the Taiwan consensus of pharmacological treatment for bipolar disorders was initiated by the Taiwanese Society of Biological Psychiatry and Neuropsychopharmacology (TSBPN – the Bipolar Chapter, which was established in August 2010 and approved as a member of International Society of Bipolar Disorder. TSBPN is the country member of the World Federation of Societies of Biological Psychiatry (WFSBP. The development of the Taiwan consensus for bipolar disorder was mainly based on the template of WFSBP Guidelines, with references to other international guidelines including the Canadian Network for Mood and Anxiety Treatments, and British Association for Psychopharmacology. We have also added Taiwanese experts’ experience, Taiwan national health insurance data, and the indications for the pharmacological treatment of bipolar disorder given by the Taiwan Department of Health, to emphasize the balance between efficacy and safety, and to make this consensus a concise, empirical, and important reference for clinical psychiatric practice.

  18. Personality traits in bipolar disorder and influence on outcome.

    Science.gov (United States)

    Sparding, Timea; Pålsson, Erik; Joas, Erik; Hansen, Stefan; Landén, Mikael

    2017-05-03

    The aim was to investigate the personality profile of bipolar disorder I and II, and healthy controls, and to study whether personality influences the course of bipolar disorder. One hundred ten patients with bipolar disorder I, 85 patients with bipolar disorder II, and 86 healthy individuals had their personality profile assessed using the Swedish universities Scales of Personality (SSP), an instrument developed to explore personality-related vulnerabilities and correlates of psychiatric disorders. Patients were followed prospectively for 2 years. To assess the impact of Neuroticism, Aggressiveness, and Disinhibition on illness course, we performed logistic regressions with the outcome variables mood episodes (depressive, hypo/manic, mixed), suicide attempts, violence, and the number of sick leave days. Bipolar disorder I and II demonstrated higher global measures of Neuroticism, Aggressiveness, and Disinhibition as compared with healthy controls. A third of the patients scored ≥1 SD above the population-based normative mean on the global neuroticism measure. The two subtypes of bipolar disorder were, however, undistinguishable on all of the personality traits. In the unadjusted model, higher neuroticism at baseline predicted future depressive episodes and suicide attempts/violent behavior, but this association disappeared when adjusting for baseline depressive symptoms as assessed with MADRS. A significant minority of the patients scored ≥1 SD above the population mean on the global measures of Neuroticism, Aggressiveness and Disinhibition; scores this high are usually evident clinically. Yet, the personality profile does not seem to have prognostic value over a 2-year period.

  19. Bipolar disorder and the pseudoautosomal region: An association study

    Energy Technology Data Exchange (ETDEWEB)

    Parsian, A.; Todd, R.D. [Washington Univ. School of Medicine, St. Louis, MO (United States)

    1994-03-15

    From family, adoption, and twin studies it is clear that genetic factors play an important role in the etiology of bipolar disorder (McGuffin and Katz: The Biology of Depression, Gaskell, London, 1986). Recently Yoneda et al. reported an association between an allele (A4) of a VNTR marker (DXYS20) for the pseudoautosomal region and bipolar disorder in a Japanese population. In order to test for this association in a Caucasian population, we have typed a sample of 52 subjects with bipolar disorder and 61 normal controls. The bipolar subjects are probands of multiple incidence families. The normal controls are an epidemiologically ascertained sample of middle-aged, unrelated individuals. The two groups were matched for sex and ethnic background. There were no significant differences in the allele or genotype frequencies of DXYS20 between the two groups. In particular, there was no significant difference in the frequency of the A4 allele in normal controls and bipolar patients (0.377 vs. 0.317, respectively). The prevalence of the A4 allele in bipolar patients and normal controls was 0.567 and 0.622, respectively. We were not able to replicate the results of the 1992 Yoneda et al. study. 15 refs., 2 tabs.

  20. Antidepressant Treatment for Acute Bipolar Depression: An Update

    Directory of Open Access Journals (Sweden)

    Ben H. Amit

    2012-01-01

    Full Text Available While studies in the past have focused more on treatment of the manic phase of bipolar disorder (BD, recent findings demonstrate the depressive phase to be at least as debilitating. However, in contrast to unipolar depression, depression in bipolar patients exhibits a varying response to antidepressants, raising questions regarding their efficacy and tolerability. Methods. We conducted a MEDLINE and Cochrane Collaboration Library search for papers published between 2005 and 2011 on the subject of antidepressant treatment of bipolar depression. Sixty-eight articles were included in the present review. Results. While a few studies did advocate the use of antidepressants, most well-controlled studies failed to show a robust effect of antidepressants in bipolar depression, regardless of antidepressant class or bipolar subtype. There was no significant increase in the rate of manic/hypomanic switch, especially with concurrent use of mood stabilizers. Prescribing guidelines published in recent years rely more on atypical antipsychotics, especially quetiapine, as a first-line therapy. Conclusions. Antidepressants probably have no substantial role in acute bipolar depression. However, in light of conflicting results between studies, more well-designed trials are warranted.