WorldWideScience

Sample records for microcomputer based system

  1. Microcomputer-based monitoring and control system

    International Nuclear Information System (INIS)

    Talaska, D.

    1979-03-01

    This report describes a microcomputer-based monitoring and control system devised within, and used by, the Cryogenic Operations group at SLAC. Presently, a version of it is operating at the one meter liquid hydrogen bubble chamber augmenting the conventional pneumatic and human feedback system. Its use has greatly improved the controlled tolerances of temperature and pulse shape, and it has nearly eliminated the need for operating personnel to adjust the conventional pneumatic control system. The latter is most important since the rapid cycling machine can demand attentions beyond the operator's skill. Similar microcomputer systems are being prepared to monitor and control cryogenic devices situated in regions of radiation which preclude human entry and at diverse locations which defy the dexterity of the few operators assigned to maintain them. An IMSAI 8080 microcomputer is basic to the system. The key to the use of the IMSAI 8080 in this system was in the development of unique interface circuitry, and the report is mostly concerned with this

  2. Microcomputer based test system for charge coupled devices

    International Nuclear Information System (INIS)

    Sidman, S.

    1981-02-01

    A microcomputer based system for testing analog charge coupled integrated circuits has been developed. It measures device performance for three parameters: dynamic range, baseline shift due to leakage current, and transfer efficiency. A companion board tester has also been developed. The software consists of a collection of BASIC and assembly language routines developed on the test system microcomputer

  3. A new dual-functional microcomputer-based system for nuclear measurement

    International Nuclear Information System (INIS)

    Zhang Jiang; Fang Fang

    2004-01-01

    Introduction is made on a new type of microcomputer-based system nuclear instrument which can be used in both α ray and γ ray measurements. This dual-functional instrument is based on P89C58 single-chip microcomputer as its core MPU to do operations like data acquisition, data processing, circuit control, display and communication. Improvement and simplification are made to the traditional single channel analyzer, which is completely dependent on the hardware circuit, through the use of P89C58. (authors)

  4. Application of a microcomputer-based system to control and monitor bacterial growth.

    Science.gov (United States)

    Titus, J A; Luli, G W; Dekleva, M L; Strohl, W R

    1984-02-01

    A modular microcomputer-based system was developed to control and monitor various modes of bacterial growth. The control system was composed of an Apple II Plus microcomputer with 64-kilobyte random-access memory; a Cyborg ISAAC model 91A multichannel analog-to-digital and digital-to-analog converter; paired MRR-1 pH, pO(2), and foam control units; and in-house-designed relay, servo control, and turbidimetry systems. To demonstrate the flexibility of the system, we grew bacteria under various computer-controlled and monitored modes of growth, including batch, turbidostat, and chemostat systems. The Apple-ISAAC system was programmed in Labsoft BASIC (extended Applesoft) with an average control program using ca. 6 to 8 kilobytes of memory and up to 30 kilobytes for datum arrays. This modular microcomputer-based control system was easily coupled to laboratory scale fermentors for a variety of fermentations.

  5. VME bus based microcomputer system boards

    International Nuclear Information System (INIS)

    Chandra, A.K.; Ganesh, G.; Mayya, Anuradha; Chachondia, A.S.; Premraj, M.K.

    1991-01-01

    Several operator information systems for nuclear plants has been developed in the Division and these have involved extensive use of microcomputer boards for achieving various functions. Standard VME bus based boards have been developed to provide the most used functions. These boards have been fabricated and tested and used in several systems including Channel Temperature Monitoring systems, Disturbance Recording Systems etc. and are also proposed to be used in additional systems under developement. The use of standard bus and boards provides considerable savings in engineering time, prototyping, testing and evaluation costs, and maintenance support. This report desribes the various boards developed and the functions available on each. (author). 4 refs., 11 figs., 3 appendixes

  6. Integrating Mainframe Data Bases on a Microcomputer

    OpenAIRE

    Marciniak, Thomas A.

    1985-01-01

    Microcomputers support user-friendly software for interrogating their resident data bases. Many medical data bases currently consist of files on less accessible mainframe computers with more limited inquiry capabilities. We discuss the transferring and integrating of mainframe data into microcomputer data base systems in one medical environment.

  7. Reliability analysis of microcomputer boards and computer based systems important to safety of nuclear plants

    International Nuclear Information System (INIS)

    Shrikhande, S.V.; Patil, V.K.; Ganesh, G.; Biswas, B.; Patil, R.K.

    2010-01-01

    Computer Based Systems (CBS) are employed in Indian nuclear plants for protection, control and monitoring purpose. For forthcoming CBS, Reactor Control Division has designed and developed a new standardized family of microcomputer boards qualified to stringent requirements of nuclear industry. These boards form the basic building blocks of CBS. Reliability analysis of these boards is being carried out using analysis package based on MIL-STD-217Plus methodology. The estimated failure rate values of these standardized microcomputer boards will be useful for reliability assessment of these systems. The paper presents reliability analysis of microcomputer boards and case study of a CBS system built using these boards. (author)

  8. Microcomputer-based real-time optical signal processing system

    Science.gov (United States)

    Yu, F. T. S.; Cao, M. F.; Ludman, J. E.

    1986-01-01

    A microcomputer-based real-time programmable optical signal processing system utilizing a Magneto-Optic Spatial Light Modulator (MOSLM) and a Liquid Crystal Light Valve (LCLV) is described. This system can perform a myriad of complicated optical operations, such as image correlation, image subtraction, matrix multiplication and many others. The important assets of this proposed system must be the programmability and the capability of real-time addressing. The design specification and the progress toward practical implementation of this proposed system are discussed. Some preliminary experimental demonstrations are conducted. The feasible applications of this proposed system to image correlation for optical pattern recognition, image subtraction for IC chip inspection and matrix multiplication for optical computing are demonstrated.

  9. A local-area-network based radiation oncology microcomputer system

    International Nuclear Information System (INIS)

    Chu, W.K.; Taylor, T.K.; Kumar, P.P.; Imray, T.J.

    1985-01-01

    The application of computerized technology in the medical specialty of radiation oncology has gained wide acceptance in the past decade. Recognizing that most radiation oncology department personnel are familiar with computer operations and terminology, it appears reasonable to attempt to expand the computer's applications to other departmental activities, such as scheduling, record keeping, billing, treatment regimen and status, etc. Instead of sharing the processing capability available on the existent treatment minicomputer, the radiation oncology computer system is based upon a microcomputer local area network (LAN). The system was conceptualized in 1984 and completed in March 1985. This article outlines the LAN-based radiation oncology computer system

  10. Versatile microcomputer-based temperature controller

    International Nuclear Information System (INIS)

    Yarberry, V.R.

    1980-09-01

    The wide range of thermal responses required in laboratory and scientific equipment requires a temperature controller with a great deal of flexibility. While a number of analog temperature controllers are commercially available, they have certain limitations, such as inflexible parameter control or insufficient precision. Most lack digital interface capabilities--a necessity when the temperature controller is part of a computer-controlled automatic data acquisition system. We have developed an extremely versatile microcomputer-based temperature controller to fulfill this need in a variety of equipment. The control algorithm used allows optimal tailoring of parameters to control overshoot, response time, and accuracy. This microcomputer-based temperature controller can be used as a standalone instrument (with a teletype used to enter para-meters), or it can be integrated into a data acquisition system

  11. A multi-channel data acquisition system with high resolution based on microcomputer

    International Nuclear Information System (INIS)

    An Qi; Wang Yanfang; Xing Tao

    1995-01-01

    The paper introduces the principle of a multi-channel data acquisition system with high resolution based on the microcomputer.The system consists of five parts.They are analog-to-digital converter, data buffer area, trigger logic circuit, control circuit, and digital-to-analog converter

  12. Information Retrieval System Design Issues in a Microcomputer-Based Relational DBMS Environment.

    Science.gov (United States)

    Wolfram, Dietmar

    1992-01-01

    Outlines the file structure requirements for a microcomputer-based information retrieval system using FoxPro, a relational database management system (DBMS). Issues relating to the design and implementation of such systems are discussed, and two possible designs are examined in terms of space economy and practicality of implementation. (15…

  13. Microcomputer control of a residential photovoltaic power conditioning system

    Energy Technology Data Exchange (ETDEWEB)

    Bose, B.K.; Steigerwald, R.L.; Szczesny, P.M.

    1984-01-01

    Microcomputer-based control of a residential photovoltaic power conditioning system is described. The microcomputer is responsible for array current feedback control, maximum power tracking control, array safe zone steering control, phase-locked reference wave synthesis, sequencing control, and some diagnostics. The control functions are implemented using Intel 8751 single-chip microcomputer-based hardware and software. The controller has been tested in the laboratory with the prototype power conditioner and shows excellent performance.

  14. Microcomputer control of a residential photovoltaic power conditioning system

    Energy Technology Data Exchange (ETDEWEB)

    Bose, B.K.; Steigerwald, R.L.; Szczesny, P.M.

    1985-09-01

    Microcomputer-based control of a residential photovoltaic power conditioning system is described. The microcomputer is responsible for array current feedback control, maximum power tracking control, array safe zone steering control, phase-locked reference wave synthesis, sequencing control, and some diagnostics. The control functions are implemented using Intel 8751 single-chip microcomputer-based hardware and software. The controller has been tested in the laboratory with the prototype power conditioner and shows excellent performance.

  15. Single-chip microcomputer based protection, diagnostic and recording system for longwall shearers

    Energy Technology Data Exchange (ETDEWEB)

    Heyduk, A.; Krasucki, F. (Politechnika Slaska, Gliwice (Poland). Katedra Elektryfikacji i Automatyzacji Gornictwa)

    1993-05-01

    Presents a concept of microcomputer-aided operation, protection, diagnostics and recording for shearer loaders. A two-stage mathematical model is suggested and explained. The model represents the thermal processes that determine the overcurrent protection of drive motors. Circuits for monitoring fuses, supply voltages, contacts, relays, contactors and electro-hydraulic distributors with the use of transoptors are shown. Recording characteristic operation parameters of a shearer loader during the 5 minutes before a failure is proposed. Protection, diagnosis and control functions are suggested as additional functions to the microcomputer-aided system of shearer loader control being developed at the Silesian Technical University. The system is based on the NECmicroPD 78310 microprocessor. 10 refs.

  16. Microcomputer-based image processing system for CT/MRI scans II

    International Nuclear Information System (INIS)

    Kwok, J.C.K.; Yu, P.K.N.; Cheng, A.Y.S.; Ho, W.C.

    1991-01-01

    This paper reports that a microcomputer-based image processing system is used to digitize and process serial sections of CT/MRI scan and reconstruct three-dimensional images of brain structures and brain lesions. The images grabbed also serve as templates and different vital regions with different risk values are also traced out for 3D reconstruction. A knowledge-based system employing rule-based programming has been built to help identifying brain lesions and to help planning trajectory for operations. The volumes of the lesions are also automatically determined. Such system is very useful for medical skills archival, tumor size monitoring, survival and outcome forecasting, and consistent neurosurgical planning

  17. AUTOCASK (AUTOmatic Generation of 3-D CASK models). A microcomputer based system for shipping cask design review analysis

    International Nuclear Information System (INIS)

    Gerhard, M.A.; Sommer, S.C.

    1995-04-01

    AUTOCASK (AUTOmatic Generation of 3-D CASK models) is a microcomputer-based system of computer programs and databases developed at the Lawrence Livermore National Laboratory (LLNL) for the structural analysis of shipping casks for radioactive material. Model specification is performed on the microcomputer, and the analyses are performed on an engineering workstation or mainframe computer. AUTOCASK is based on 80386/80486 compatible microcomputers. The system is composed of a series of menus, input programs, display programs, a mesh generation program, and archive programs. All data is entered through fill-in-the-blank input screens that contain descriptive data requests

  18. AUTOCASK (AUTOmatic Generation of 3-D CASK models). A microcomputer based system for shipping cask design review analysis

    Energy Technology Data Exchange (ETDEWEB)

    Gerhard, M.A.; Sommer, S.C. [Lawrence Livermore National Lab., CA (United States)

    1995-04-01

    AUTOCASK (AUTOmatic Generation of 3-D CASK models) is a microcomputer-based system of computer programs and databases developed at the Lawrence Livermore National Laboratory (LLNL) for the structural analysis of shipping casks for radioactive material. Model specification is performed on the microcomputer, and the analyses are performed on an engineering workstation or mainframe computer. AUTOCASK is based on 80386/80486 compatible microcomputers. The system is composed of a series of menus, input programs, display programs, a mesh generation program, and archive programs. All data is entered through fill-in-the-blank input screens that contain descriptive data requests.

  19. Design of microcomputer-based data acquisition system for the time-of-flight ion scattering spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Lo, H; Su, C [National Tsing Hua Univ., Hsinchu (Taiwan). Inst. of Nuclear Engineering

    1981-07-15

    A microcomputer-based data aquisition system used on a time-of-flight ion scattering spectrometer is described. The flight time of 90/sup 0/-scattered ions from target atom determined directly with a 30 MHz crystal-controlled oscillator and its associated circuit. The ion intensity is detected by a channel multiplier, and its output signal pulse is converted from the analog form into digital form by an ADC. Both flight time and ion intensity are stored in the microcomputer.

  20. Design of microcomputer-based data acquisition system for the time-of-flight ion scattering spectrometer

    International Nuclear Information System (INIS)

    Lo, H.; Su, C.

    1981-01-01

    A microcomputer-based data aquisition system used on a time-of-flight ion scattering spectrometer is described. The flight time of 90 0 -scattered ions from target atom determined directly with a 30 MHz crystal-controlled oscillator and its associated circuit. The ion intensity is detected by a channel multiplier, and its output signal pulse is converted from the analog form into digital form by an ADC. Both flight time and ion intensity are stored in the microcomputer. (orig.)

  1. MINDS: A microcomputer interactive data system for 8086-based controllers

    Science.gov (United States)

    Soeder, J. F.

    1985-01-01

    A microcomputer interactive data system (MINDS) software package for the 8086 family of microcomputers is described. To enhance program understandability and ease of code maintenance, the software is written in PL/M-86, Intel Corporation's high-level system implementation language. The MINDS software is intended to run in residence with real-time digital control software to provide displays of steady-state and transient data. In addition, the MINDS package provides classic monitor capabilities along with extended provisions for debugging an executing control system. The software uses the CP/M-86 operating system developed by Digital Research, Inc., to provide program load capabilities along with a uniform file structure for data and table storage. Finally, a library of input and output subroutines to be used with consoles equipped with PL/M-86 and assembly language is described.

  2. Microcomputer Database Management Systems for Bibliographic Data.

    Science.gov (United States)

    Pollard, Richard

    1986-01-01

    Discusses criteria for evaluating microcomputer database management systems (DBMS) used for storage and retrieval of bibliographic data. Two popular types of microcomputer DBMS--file management systems and relational database management systems--are evaluated with respect to these criteria. (Author/MBR)

  3. A microcomputer controlled thermoluminescence dosimetry system

    International Nuclear Information System (INIS)

    Huyskens, C.J.; Kicken, P.J.H.

    1980-01-01

    Using a microcomputer, an automatic thermoluminescence dosimetry system for personal dosimetry and thermoluminescence detector (TLD) research was developed. Process automation, statistical computation and dose calculation are provided by this microcomputer. Recording of measurement data, as well as dose record keeping for radiological workers is carried out with floppy disk. The microcomputer also provides a human/system interface by means of a video display and a printer. The main features of this dosimetry system are its low cost, high degree of flexibility, high degree of automation and the feasibility for use in routine dosimetry as well as in TLD research. The system is in use for personal dosimetry, environmental dosimetry and for TL-research work. Because of its modular set-up several components of the system are in use for other applications, too. The system seems suited for medium sized health physics groups. (author)

  4. Micro-computer based control system and its software for carrying out the sequential acceleration on SMCAMS

    International Nuclear Information System (INIS)

    Li Deming

    2001-01-01

    Micro-computer based control system and its software for carrying out the sequential acceleration on SMCAMS is described. Also, the establishment of the 14 C particle measuring device and the improvement of the original power supply system are described

  5. Accessing remote data bases using microcomputers

    OpenAIRE

    Saul, Peter D.

    1985-01-01

    General practitioners' access to remote data bases using microcomputers is increasing, making even the most obscure information readily available. Some of the systems available to general practitioners in the UK are described and the methods of access are outlined. General practitioners should be aware of the advances in technology; data bases are increasing in size, the cost of access is falling and their use is becoming easier.

  6. Microcomputer-based pneumatic controller for neutron activation analysis

    International Nuclear Information System (INIS)

    Byrd, J.S.; Sand, R.J.

    1976-10-01

    A microcomputer-based pneumatic controller for neutron activation analysis was designed and built at the Savannah River Laboratory for analysis of large numbers of geologic samples for locating potential supplies of uranium ore for the National Uranium Resource Evaluation program. In this system, commercially available microcomputer logic modules are used to transport sample capsules through a network of pressurized air lines. The logic modules are interfaced to pneumatic valves, solenoids, and photo-optical detectors. The system operates from programs stored in firmware (permanent software). It also commands a minicomputer and a hard-wired pulse height analyzer for data collection and bookkeeping tasks. The advantage of the system is that major system changes can be implemented in the firmware with no hardware changes. This report describes the hardware, firmware, and software for the electronics system

  7. Toyota's new single-chip microcomputer based engine and transmission control system

    Energy Technology Data Exchange (ETDEWEB)

    Kawamura, T.; Kawai, M.; Aoki, K.; Tamaki, K.; Sugawara, M.

    1985-01-01

    Toyota succeeded in the fall of 1984 in manufacturing a complex engine and transmission control system using a newly developed single-chip microcomputer. This microcomputer, equipped with an 8K-byte ROM (Read Only Memory) and a 256-byte RAM (Random Access Memory), a powerful real time processing function, and a high-speed optimum instruction set, is better suited for automobiles. Application of the latest CMOS technology has enabled lower power consumption and improved noise immunity. The new system, which includes a new function; the electronic spark advance with knock control in addition to the conventional sophisticated system, has greatly improved the performance and driveability of vehicles. The newly designed electronic control unit (ECU) has been greatly improved in reliability and has not changed in its size with the adoption of the highly integrated new microcomputer, which is due to the fact that it uses fewer LSIs (Large Scale Integrated circuits) than the conventional ECU, although it includes the great additional function.

  8. Experiments with microcomputer-based artificial intelligence environments

    Science.gov (United States)

    Summers, E.G.; MacDonald, R.A.

    1988-01-01

    The U.S. Geological Survey (USGS) has been experimenting with the use of relatively inexpensive microcomputers as artificial intelligence (AI) development environments. Several AI languages are available that perform fairly well on desk-top personal computers, as are low-to-medium cost expert system packages. Although performance of these systems is respectable, their speed and capacity limitations are questionable for serious earth science applications foreseen by the USGS. The most capable artificial intelligence applications currently are concentrated on what is known as the "artificial intelligence computer," and include Xerox D-series, Tektronix 4400 series, Symbolics 3600, VAX, LMI, and Texas Instruments Explorer. The artificial intelligence computer runs expert system shells and Lisp, Prolog, and Smalltalk programming languages. However, these AI environments are expensive. Recently, inexpensive 32-bit hardware has become available for the IBM/AT microcomputer. USGS has acquired and recently completed Beta-testing of the Gold Hill Systems 80386 Hummingboard, which runs Common Lisp on an IBM/AT microcomputer. Hummingboard appears to have the potential to overcome many of the speed/capacity limitations observed with AI-applications on standard personal computers. USGS is a Beta-test site for the Gold Hill Systems GoldWorks expert system. GoldWorks combines some high-end expert system shell capabilities in a medium-cost package. This shell is developed in Common Lisp, runs on the 80386 Hummingboard, and provides some expert system features formerly available only on AI-computers including frame and rule-based reasoning, on-line tutorial, multiple inheritance, and object-programming. ?? 1988 International Association for Mathematical Geology.

  9. A multi-channel microcomputer data acquisition system

    International Nuclear Information System (INIS)

    Loureiro, J.S.

    1987-01-01

    A data acquisition system was developed in order to transfer automatically to a 64 kb microcomputer the data generated by a nuclear spectroscopy system in a multichannel analyser. The data in the memory are stored in a floppy disk and will be further used as data entry for any spectrum analysis program, eliminating the tedious work of manually digitizing the spectrum and the possible mistakes associated with it. The developed system connected a POLYMAX 201 DP microcomputer, under CP/M operational system, to a NUCLEAR DATA MODEL ND-65 multichannel analyser and was planned for either local spectrum analysis in the microcomputer using a simplified program, or remote analysis in a mainframe using the sophisticated analysis program SAMPO. With the present system, the time spent between printing out of the 4096 channels with the multichannel analyser printer and its corresponding introduction in the analysis program has been reduced from about 6 hours to less than 2 minutes. (author)

  10. Reactor protection system design using micro-computers

    International Nuclear Information System (INIS)

    Fairbrother, D.B.

    1977-01-01

    Reactor Protection Systems for Nuclear Power Plants have traditionally been built using analog hardware. This hardware works quite well for single parameter trip functions; however, optimum protection against DNBR and KW/ft limits requires more complex trip functions than can easily be handled with analog hardware. For this reason, Babcock and Wilcox has introduced a Reactor Protection System, called the RPS-II, that utilizes a micro-computer to handle the more complex trip functions. This paper describes the design of the RPS-II and the operation of the micro-computer within the Reactor Protection System

  11. Reactor protection system design using micro-computers

    International Nuclear Information System (INIS)

    Fairbrother, D.B.

    1976-01-01

    Reactor protection systems for nuclear power plants have traditionally been built using analog hardware. This hardware works quite well for single parameter trip functions; however, optimum protection against DNBR and KW/ft limits requires more complex trip functions than can easily be handled with analog hardware. For this reason, Babcock and Wilcox has introduced a Reactor Protection System, called the RPS-II, that utilizes a micro-computer to handle the more complex trip functions. The paper describes the design of the RPS-II and the operation of the micro-computer within the Reactor Protection System

  12. A multi-microcomputer system for Monte Carlo calculations

    International Nuclear Information System (INIS)

    Hertzberger, L.O.; Berg, B.; Krasemann, H.

    1981-01-01

    We propose a microcomputer system which allows parallel processing for Monte Carlo calculations in lattice gauge theories, simulations of high energy physics experiments and presumably many other fields of current interest. The master-n-slave multiprocessor system is based on the Motorola MC 68000 microprocessor. One attraction if this processor is that it allows up to 16 M Byte random access memory. (orig.)

  13. A new microcomputer-based safety and life support system for solitary-living elderly people.

    Science.gov (United States)

    Miyauchi, Kosuke; Yonezawa, Yoshiharu; Maki, Hiromichi; Ogawa, Hidekuni; Hahn, Allen W; Caldwell, W Morton

    2003-01-01

    A new safety and life support system has been developed to detect emergency situations of solitary-living elderly persons. The system employs a dual axis accelerometer, two low-power active filters, a low-power 8-bit single chip microcomputer and a personal handy phone. Body movements due to walking, running and posture changes are detected by the dual axis accelerometer and sent to the microcomputer. If the patient is in an inactive state for 5 minutes after falling, or for 64 minutes without previously falling, then the system automatically alarms the emergency situation, via the personal handy phone, to the patient's family, the fire station or the hospital.

  14. Development of a microcomputer data base of manufacturing, installation, and operating experience for the NSSS designer

    International Nuclear Information System (INIS)

    Borchers, W.A.; Markowski, E.S.

    1986-01-01

    Future nuclear steam supply systems (NSSSs) will be designed in an environment of powerful micro hardware and software and these systems will be linked by local area networks (LAN). With such systems, individual NSSS designers and design groups will establish and maintain local data bases to replace existing manual files and data sources. One such effort of this type in Combustion Engineering's (C-E's) NSSS engineering organization is the establishment of a data base of historical manufacturing, installation, and operating experience to provide designers with information to improve on current designs and practices. In contrast to large mainframe or minicomputer data bases, which compile industry-wide data, the data base described here is implemented on a microcomputer, is design specific, and contains a level of detail that is of interest to system and component designers. DBASE III, a popular microcomputer data base management software package, is used. In addition to the immediate benefits provided by the data base, the development itself provided a vehicle for identifying procedural and control aspects that need to be addressed in the environment of local microcomputer data bases. This paper describes the data base and provides some observations on the development, use, and control of local microcomputer data bases in a design organization

  15. Small, microcomputer-based CAMAC controller

    International Nuclear Information System (INIS)

    Juras, R.C.

    1979-01-01

    The beam buncher necessary to condition the beam from the Oak Ridge National Laboratory 25 MV tandem accelerator for post-acceleration by the Oak Ridge Isochronous Cyclotron is CAMAC-based and will be controlled via one of the serial highways of the accelerator control system. However, prior to integration into the accelerator system, the buncher requires testing, including runs on the model EN tandem at Oak Ridge. In order to facilitate testing and initial operation of the buncher, a microcomputer-based controller was assembled. The controller consists of a CAMAC crate, several CAMAC modules, a touch panel display, a controller box, and software. The controller box contains one shaft encoder and two switches. One of the switches is a coarse/fine selector. The other switch is assignable via the touch panel display and is used, for example, to turn devices on and off. Operation of the controller is described. It can be quickly assembled to control any small CAMAC-based system. 2 figures

  16. A versatile data handling system for nuclear physics experiments based on PDP 11/03 micro-computers

    International Nuclear Information System (INIS)

    Raaf, A.J. de

    1979-01-01

    A reliable and low cost data handling system for nuclear physics experiments is described. It is based on two PDP 11/03 micro-computers together with Gec-Elliott CAMAC equipment. For the acquisition of the experimental data a fast system has been designed. It consists of a controller for four ADCs together with an intelligent 38k MOS memory with a word size of 24 bits. (Auth.)

  17. Microcomputer-based system for registration of oxygen tension in peripheral muscle.

    Science.gov (United States)

    Odman, S; Bratt, H; Erlandsson, I; Sjögren, L

    1986-01-01

    For registration of oxygen tension fields in peripheral muscle a microcomputer based system was designed on the M6800 microprocessor. The system was designed to record the signals from a multiwire oxygen electrode, MDO, which is a multiwire electrode for measuring oxygen on the surface of an organ. The system contained patient safety isolation unit built on optocopplers and the upper frequency limit was 0.64 Hz. Collected data were corrected for drift and temperature changes during the measurement by using pre- and after calibrations and a linear compensation technique. Measure drift of the electrodes were proved to be linear and thus the drift could be compensated for. The system was tested in an experiment on pig. To study the distribution of oxygen statistically mean, standard deviation, skewness and curtosis were calculated. To see changes or differences between histograms a Kolmogorv-Smirnov test was used.

  18. Microcomputer system for controlling fuel rod length

    International Nuclear Information System (INIS)

    Meyer, E.R.; Bouldin, D.W.; Bolfing, B.J.

    1979-01-01

    A system is being developed at the Oak Ridge National Laboratory (ORNL) to automatically measure and control the length of fuel rods for use in a high temperature gas-cooled reactor (HTGR). The system utilizes an LSI-11 microcomputer for monitoring fuel rod length and for adjusting the primary factor affecting length. Preliminary results indicate that the automated system can maintain fuel rod length within the specified limits of 1.940 +- 0.040 in. This system provides quality control documentation and eliminates the dependence of the current fuel rod molding process on manual length control. In addition, the microcomputer system is compatible with planned efforts to extend control to fuel rod fissile and fertile material contents

  19. Automating Relational Database Design for Microcomputer Users.

    Science.gov (United States)

    Pu, Hao-Che

    1991-01-01

    Discusses issues involved in automating the relational database design process for microcomputer users and presents a prototype of a microcomputer-based system (RA, Relation Assistant) that is based on expert systems technology and helps avoid database maintenance problems. Relational database design is explained and the importance of easy input…

  20. SCANS (Shipping Cask ANalysis System) a microcomputer-based analysis system for shipping cask design review: User's manual to Version 3a. Volume 1, Revision 2

    International Nuclear Information System (INIS)

    Mok, G.C.; Thomas, G.R.; Gerhard, M.A.; Trummer, D.J.; Johnson, G.L.

    1998-03-01

    SCANS (Shipping Cask ANalysis System) is a microcomputer-based system of computer programs and databases developed at the Lawrence Livermore National Laboratory (LLNL) for evaluating safety analysis reports on spent fuel shipping casks. SCANS is an easy-to-use system that calculates the global response to impact loads, pressure loads and thermal conditions, providing reviewers with an independent check on analyses submitted by licensees. SCANS is based on microcomputers compatible with the IBM-PC family of computers. The system is composed of a series of menus, input programs, cask analysis programs, and output display programs. All data is entered through fill-in-the-blank input screens that contain descriptive data requests. Analysis options are based on regulatory cases described in the Code of Federal Regulations 10 CFR 71 and Regulatory Guides published by the US Nuclear Regulatory Commission in 1977 and 1978

  1. Implementation of relational data base management systems on micro-computers

    International Nuclear Information System (INIS)

    Huang, C.L.

    1982-01-01

    This dissertation describes an implementation of a Relational Data Base Management System on a microcomputer. A specific floppy disk based hardward called TERAK is being used, and high level query interface which is similar to a subset of the SEQUEL language is provided. The system contains sub-systems such as I/O, file management, virtual memory management, query system, B-tree management, scanner, command interpreter, expression compiler, garbage collection, linked list manipulation, disk space management, etc. The software has been implemented to fulfill the following goals: (1) it is highly modularized. (2) The system is physically segmented into 16 logically independent, overlayable segments, in a way such that a minimal amount of memory is needed at execution time. (3) Virtual memory system is simulated that provides the system with seemingly unlimited memory space. (4) A language translator is applied to recognize user requests in the query language. The code generation of this translator generates compact code for the execution of UPDATE, DELETE, and QUERY commands. (5) A complete set of basic functions needed for on-line data base manipulations is provided through the use of a friendly query interface. (6) To eliminate the dependency on the environment (both software and hardware) as much as possible, so that it would be easy to transplant the system to other computers. (7) To simulate each relation as a sequential file. It is intended to be a highly efficient, single user system suited to be used by small or medium sized organizations for, say, administrative purposes. Experiments show that quite satisfying results have indeed been achieved

  2. Microcomputer-based equipment-control and data-acquisition system for fission-reactor reactivity-worth measurements

    International Nuclear Information System (INIS)

    McDowell, W.P.; Bucher, R.G.

    1980-01-01

    Material reactivity-worth measurements are one of the major classes of experiments conducted on the Zero Power research reactors (ZPR) at Argonne National Laboratory. These measurements require the monitoring of the position of a servo control element as a sample material is positioned at various locations in a critical reactor configuration. In order to guarantee operational reliability and increase experimental flexibility for these measurements, the obsolete hardware-based control unit has been replaced with a microcomputer based equipment control and data acquisition system. This system is based on an S-100 bus, dual floppy disk computer with custom built cards to interface with the experimental system. To measure reactivity worths, the system accurately positions samples in the reactor core and acquires data on the position of the servo control element. The data are then analyzed to determine statistical adequacy. The paper covers both the hardware and software aspects of the design

  3. Microcomputer-based equipment-control and data-acquisition system for fission-reactor reactivity-worth measurements

    Energy Technology Data Exchange (ETDEWEB)

    McDowell, W.P.; Bucher, R.G.

    1980-01-01

    Material reactivity-worth measurements are one of the major classes of experiments conducted on the Zero Power research reactors (ZPR) at Argonne National Laboratory. These measurements require the monitoring of the position of a servo control element as a sample material is positioned at various locations in a critical reactor configuration. In order to guarantee operational reliability and increase experimental flexibility for these measurements, the obsolete hardware-based control unit has been replaced with a microcomputer based equipment control and data acquisition system. This system is based on an S-100 bus, dual floppy disk computer with custom built cards to interface with the experimental system. To measure reactivity worths, the system accurately positions samples in the reactor core and acquires data on the position of the servo control element. The data are then analyzed to determine statistical adequacy. The paper covers both the hardware and software aspects of the design.

  4. Reactor core protection system using a 4-channel microcomputer

    International Nuclear Information System (INIS)

    Mertens, U.

    1982-12-01

    A four channel microcomputer system was fitted in Grafenrheinfeld NPP for local core protection. This system performs continuous on-line monitoring of peak power density, departure from nucleate boiling ratio and fuel duty. The system implements limitation functions with more sophisticated criteria and improved accuracy. The Grafenrheinfeld system points the way to the employment of computer based limitation system, particularly in the field of programming language, demarkation of tasks, commissioning and documentation aids, streamlining of qualification and structuring of the system. (orig.) [de

  5. A microcomputer-based daily living activity recording system.

    Science.gov (United States)

    Matsuoka, Shingo; Yonezawa, Yoshiharu; Maki, Hiromichi; Ogawa, Hidekuni; Hahn, Allen W; Thayer, Julian F; Caldwell, W Morton

    2003-01-01

    A new daily living activity recording system has been developed for monitoring health conditions and living patterns, such as respiration, posture, activity/rest ratios and general activity level. The system employs a piezoelectric sensor, a dual axis accelerometer, two low-power active filters, a low-power 8-bit single chip microcomputer and a 128 MB compact flash memory. The piezoelectric sensor, whose electrical polarization voltage is produced by mechanical strain, detects body movements. Its high-frequency output components reflect body movements produced by walking and running activities, while the low frequency components are mainly respiratory. The dual axis accelerometer detects, from body X and Y tilt angles, whether the patient is standing, sitting or lying down (prone, supine, left side or right side). The detected respiratory, behavior and posture signals are stored by the compact flash memory. After recording, these data are downloaded to a desktop computer and analyzed.

  6. A nuclear pulse amplitude acquisition system based on 80C31 single-chip microcomputer

    International Nuclear Information System (INIS)

    Zhao Xiuliang; Qu Guopu; Guo Lanying; Zhang Songbai

    1999-01-01

    A kind of multichannel nuclear pulse amplitude signal acquisition system is described, which is composed of pulse peak detector, integrated S/H circuit, A/D converter and 80C31 single-chip microcomputer

  7. Measuring the efficacy of flunixin meglumine and meloxicam for lame sows using a GAITFour pressure mat and an embedded microcomputer-based force plate system.

    Science.gov (United States)

    Pairis-Garcia, M D; Johnson, A K; Abell, C A; Coetzee, J F; Karriker, L A; Millman, S T; Stalder, K J

    2015-05-01

    Pain associated with lameness on farm is a negative affective state and has a detrimental impact on individual farm animal welfare. Animal pain can be managed utilizing husbandry tools and through pharmacological approaches. Nonsteroidal anti-inflammatory drugs including meloxicam and flunixin meglumine are compounds used in many species for pain management because they are easy to administer, long lasting, and cost-effective. Assessing an animal's biomechanical parameters using such tools as the embedded microcomputer-based force plate system and GAITFour pressure mat gait analysis walkway system provides an objective, sensitive, and precise means to detect animals in lame states. The objectives of this study were to determine the efficacy of meloxicam and flunixin meglumine for pain mitigation in lame sows using the embedded microcomputer-based force plate system and GAITFour pressure mat gait analysis walkway system. Lameness was induced in 24 mature mixed-parity sows using a chemical synovitis model and compared 3 treatments: meloxicam (1.0 mg/kg per os), flunixin meglumine (2.2 mg/kg intramuscular) and sterile saline (intramuscular). Weight distribution (kg) for each foot was collected twice per second for a total of 5 min for each time point using the embedded microcomputer-based force plate system. Stride time, stride length, maximum pressure, activated sensors, and stance time were collected using 3 quality walks (readings) for each time point using the GAITFour pressure mat gait analysis walkway system. Sows administered flunixin meglumine or meloxicam tolerated more weight on their lame leg compared with saline sows (P embedded microcomputer-based force plate system and GAITFour pressure mat gait analysis walkway system. Analgesic drugs may be a key tool to manage negative pain affective states associated with lameness.

  8. Microcomputer-based stepping-motor controller

    International Nuclear Information System (INIS)

    Johnson, K.

    1983-04-01

    A microcomputer-controlled stepping motor is described. A Motorola MC68701 microcomputer unit is interfaced to a Cybernetic CY500 stored-program controller that outputs through Motorola input/output isolation modules to the stepping motor. A complex multifunction controller with enhanced capabilities is thus available with a minimum number of parts

  9. A microcomputer-based waveform generator for Moessbauer spectrometers

    International Nuclear Information System (INIS)

    Huang Jianping; Chen Xiaomei

    1995-01-01

    A waveform generator for Moessbauer spectrometers based on 8751 single chip microcomputer is described. The reference wave form with high linearity is generated with a 12 bit DAC, and its amplitude is controlled with a 8 bit DAC. Because the channel advance and synchronous signals can be delayed arbitrarily, excellent folded spectra can be acquired. This waveform generator can be controlled with DIP switches on faceplate or series interface of the IBM-PC microcomputer

  10. A Real-Time Image Acquisition And Processing System For A RISC-Based Microcomputer

    Science.gov (United States)

    Luckman, Adrian J.; Allinson, Nigel M.

    1989-03-01

    A low cost image acquisition and processing system has been developed for the Acorn Archimedes microcomputer. Using a Reduced Instruction Set Computer (RISC) architecture, the ARM (Acorn Risc Machine) processor provides instruction speeds suitable for image processing applications. The associated improvement in data transfer rate has allowed real-time video image acquisition without the need for frame-store memory external to the microcomputer. The system is comprised of real-time video digitising hardware which interfaces directly to the Archimedes memory, and software to provide an integrated image acquisition and processing environment. The hardware can digitise a video signal at up to 640 samples per video line with programmable parameters such as sampling rate and gain. Software support includes a work environment for image capture and processing with pixel, neighbourhood and global operators. A friendly user interface is provided with the help of the Archimedes Operating System WIMP (Windows, Icons, Mouse and Pointer) Manager. Windows provide a convenient way of handling images on the screen and program control is directed mostly by pop-up menus.

  11. Microcomputer control system for the SuperHILAC third injector

    International Nuclear Information System (INIS)

    Lancaster, H.D.; Magyary, S.B.; Glatz, J.; Selph, F.B.; Fahmie, M.P.; Ritchie, A.L.; Keith, S.R.; Stover, G.R.; Besse, L.J.

    1979-09-01

    A new control system using the latest technology in microcomputers will be used on the third injector at the SuperHILAC. It incorporates some new and progressive ideas in both hardware and software design. These ideas were inspired by the revolution in microprocessors. The third injector project consists of a high voltage pre-injector, a Wideroe type linear accelerator, and connecting beam lines, requiring control of 80 analog and 300 boolean devices. To solve this problem, emphasizing inexpensive, commercially available hardware, we designed a control system consisting of 20 microcomputer boards with a total of 700 kilobytes of memory. Each computer board using a 16-bit microprocessor has the computing power of a typical minicomputer. With these microcomputers operating in parallel, the programming can be greatly simplified, literally replacing software with hardware. This improves system response speed and cuts costs dramatically. An easy to use interpretive language, similar to BASIC, will allow operations personnel to write special purpose programs in addition to the compiled procedures

  12. Bubble Chamber Research Group Microcomputer Unit

    International Nuclear Information System (INIS)

    Bairstow, R.; Barlow, J.; Mace, P.R.; Seller, P.; Waters, M.; Watson, J.G.

    1982-05-01

    A distributed data acquisition system has been developed by the Bubble Chamber Research Group at the Rutherford Appleton laboratory for use with their film measuring machines. The system is based upon a set of microcomputers linked together with a VAX 11/780 computer, in a local area computer network. This network is of the star type and uses a packet switching technique. Each film measuring machine is equipped with a microcomputer which controls the function of the table, buffers data and enhances the interface between operators and machines. This paper provides a detailed description of each microcomputer and can be used as a reference manual for these computers. (author)

  13. A microcomputer controlled sample changer system for γ-ray spectroscopy

    International Nuclear Information System (INIS)

    Jost, D.T.; Kraehenbuehl, U.; Gunten, H.R. von

    1982-01-01

    A Z-80 based microcomputer is used to control a sample changer system connected to two γ-ray spectrometers. Samples are changed according to preselected counting criteria (maximum time and/or desired precision). Special precautions were taken to avoid the loss of information and of samples in case of a power failure. (orig.)

  14. A microcomputer-based data acquisition system for ECG, body and ambient temperatures measurement during bathing.

    Science.gov (United States)

    Uokawa, Y; Yonezawa, Y; Caldwell, W M; Hahn, A W

    2000-01-01

    A data acquisition system employing a low power 8 bit microcomputer has been developed for heart rate variability monitoring before, during and after bathing. The system consists of three integral chest electrodes, two temperature sensors, an instrumentation amplifier, a low power 8-bit single chip microcomputer (SMC) and a 4 MB compact flash memory (CFM). The ECG from the electrodes is converted to an 8-bit digital format at a 1 ms rate by an A/D converter in the SMC. Both signals from the body and ambient temperature sensors are converted to an 8-bit digital format every 1 second. These data are stored by the CFM. The system is powered by a rechargeable 3.6 V lithium battery. The 4 x 11 x 1 cm system is encapsulated in epoxy and silicone, yielding a total volume of 44 cc. The weight is 100 g.

  15. Laser-based measuring equipment controlled by microcomputer

    International Nuclear Information System (INIS)

    Miron, N.; Sporea, D.; Velculescu, V.G.; Petre, M.

    1988-03-01

    Some laser-based measuring equipment controlled by microcomputer developed for industrial and scientific purposes are described. These equipments are intended for dial indicators verification, graduated rules measurement, and for very accurate measurement of the gravitational constant. (authors)

  16. The Energetik V microcomputer system for a 210 megawatt power unit

    Energy Technology Data Exchange (ETDEWEB)

    Mumdzhiyan, G.; Astradzhiyan, G.; Ganchev, T.; Stanchev, V.

    1982-01-01

    Contemporary concepts of management and testing of a thermoelectric power plant (TES) using microcomputer systems (MKS) characterize four principles: the division of the whole system into functional groups; clear formulation and limitation of the functions of the information system, shielding, the automatic regulation system (SAR) and distinct control; strict standardization of the heirarchical levels and decentralization, including the preparation of signals for regulation and control; maximal centralization at the upper level of testing. In developing a microcomputer system for a 210 megawatt unit, the constant expansion of the functions of the microcomputer system and its software, realized in the form of program modules was provided, along with the back up of measurement systems, the wide use of dialog terminals and so on. SM 601 or MS 6800 microprocessors are used in the system. The capacity of the basic storage devices are a passive 34 kilobytes and an operational storage capacity of 16 kilobytes.

  17. Microcomputers: An Interlibrary Loan Application.

    Science.gov (United States)

    Evans, Elizabeth A.

    1984-01-01

    Description of a microcomputer-based system for local processing of interlibrary loan (ILL) requests developed at Environmental Protection Agency library discusses database management systems, hardware, databases, and command files. Subsequent changes resulting from system's implementation at East Carolina University Health Sciences Library are…

  18. Investigating Electromagnetic Induction through a Microcomputer-Based Laboratory.

    Science.gov (United States)

    Trumper, Ricardo; Gelbman, Moshe

    2000-01-01

    Describes a microcomputer-based laboratory experiment designed for high school students that very accurately analyzes Faraday's law of electromagnetic induction, addressing each variable separately while the others are kept constant. (Author/CCM)

  19. A new intelligent curtain control system based on 51 single chip microcomputer

    Science.gov (United States)

    Sun, Tuan; Wang, Yanhua; Wu, Mengmeng

    2017-04-01

    This paper uses 51 (single chip microcomputer) SCM as the operation and data processing center. According to the change of sunshine intensity and ambient temperature, a new type of intelligent curtain control system is designed by adopting photosensitive element and temperature sensor. In addition, the design also has a manual control mode. In the rain, when the light intensity is weak, the open position of the curtain can be set by the user. The system can maximize the user to provide user-friendly operation and comfortable living environment. The system can be applied to home or office environment, with a wide range of applications and simple operation and so on.

  20. Microcomputer-Based Digital Signal Processing Laboratory Experiments.

    Science.gov (United States)

    Tinari, Jr., Rocco; Rao, S. Sathyanarayan

    1985-01-01

    Describes a system (Apple II microcomputer interfaced to flexible, custom-designed digital hardware) which can provide: (1) Fast Fourier Transform (FFT) computation on real-time data with a video display of spectrum; (2) frequency synthesis experiments using the inverse FFT; and (3) real-time digital filtering experiments. (JN)

  1. On-line system on the base of the ELEKTRONIKA D3-28 microcomputer for gas filling

    International Nuclear Information System (INIS)

    Artemov, A.A.; Baranchuk, N.S.; Livitskij, M.M.; Platonov, V.P.; Chernyak, V.Ya.

    1989-01-01

    On-line system for gas filling on the base of SNA-1 pressure controller, ELEKTRONIKA D3-28 microcomputer and interface device and program for information exchange within the system are described. The system is designed for on-line measurement of gas pressure and filling and is used during operation without pumping out. Volume of vacuum chamber is 0.8 m 3 , pressure of filled-out gas (nitrogen) is 1 atm. The system enables to change pressure up to 0.1 Torr with 1x10 -4 Torr accuracy. Actuation time of g as filling-on system is determined with program control and depends on pressure measurement. Minimal actuation time of gas filling-on system is determined with program control and depends on pressure measurement. Minimal actuation time is 12 ms

  2. Remote monitor used on the 13N leak rate measurement system based on single-chip microcomputer

    International Nuclear Information System (INIS)

    Tang Rulong; Qiu Xiaoping; Guo Lanying

    2012-01-01

    It describes a design on Remote Monitor based on single-chip microcomputer, and also presents the design procedure of hardware and software for circuit design, and gives some of specific instructions about the important parts of the design. (authors)

  3. The microcomputer workstation - An alternate hardware architecture for remotely sensed image analysis

    Science.gov (United States)

    Erickson, W. K.; Hofman, L. B.; Donovan, W. E.

    1984-01-01

    Difficulties regarding the digital image analysis of remotely sensed imagery can arise in connection with the extensive calculations required. In the past, an expensive large to medium mainframe computer system was needed for performing these calculations. For image-processing applications smaller minicomputer-based systems are now used by many organizations. The costs for such systems are still in the range from $100K to $300K. Recently, as a result of new developments, the use of low-cost microcomputers for image processing and display systems appeared to have become feasible. These developments are related to the advent of the 16-bit microprocessor and the concept of the microcomputer workstation. Earlier 8-bit microcomputer-based image processing systems are briefly examined, and a computer workstation architecture is discussed. Attention is given to a microcomputer workstation developed by Stanford University, and the design and implementation of a workstation network.

  4. Interactive display of molecular models using a microcomputer system

    Science.gov (United States)

    Egan, J. T.; Macelroy, R. D.

    1980-01-01

    A simple, microcomputer-based, interactive graphics display system has been developed for the presentation of perspective views of wire frame molecular models. The display system is based on a TERAK 8510a graphics computer system with a display unit consisting of microprocessor, television display and keyboard subsystems. The operating system includes a screen editor, file manager, PASCAL and BASIC compilers and command options for linking and executing programs. The graphics program, written in USCD PASCAL, involves the centering of the coordinate system, the transformation of centered model coordinates into homogeneous coordinates, the construction of a viewing transformation matrix to operate on the coordinates, clipping invisible points, perspective transformation and scaling to screen coordinates; commands available include ZOOM, ROTATE, RESET, and CHANGEVIEW. Data file structure was chosen to minimize the amount of disk storage space. Despite the inherent slowness of the system, its low cost and flexibility suggests general applicability.

  5. CASKS (Computer Analysis of Storage casKS): A microcomputer based analysis system for storage cask design review. User's manual to Version 1b (including program reference)

    International Nuclear Information System (INIS)

    Chen, T.F.; Gerhard, M.A.; Trummer, D.J.; Johnson, G.L.; Mok, G.C.

    1995-02-01

    CASKS (Computer Analysis of Storage casKS) is a microcomputer-based system of computer programs and databases developed at the Lawrence Livermore National Laboratory (LLNL) for evaluating safety analysis reports on spent-fuel storage casks. The bulk of the complete program and this user's manual are based upon the SCANS (Shipping Cask ANalysis System) program previously developed at LLNL. A number of enhancements and improvements were added to the original SCANS program to meet requirements unique to storage casks. CASKS is an easy-to-use system that calculates global response of storage casks to impact loads, pressure loads and thermal conditions. This provides reviewers with a tool for an independent check on analyses submitted by licensees. CASKS is based on microcomputers compatible with the IBM-PC family of computers. The system is composed of a series of menus, input programs, cask analysis programs, and output display programs. All data is entered through fill-in-the-blank input screens that contain descriptive data requests

  6. 275 C Downhole Microcomputer System

    Energy Technology Data Exchange (ETDEWEB)

    Chris Hutchens; Hooi Miin Soo

    2008-08-31

    An HC11 controller IC and along with serial SRAM and ROM support ICs chip set were developed to support a data acquisition and control for extreme temperature/harsh environment conditions greater than 275 C. The 68HC11 microprocessor is widely used in well logging tools for control, data acquisition, and signal processing applications and was the logical choice for a downhole controller. This extreme temperature version of the 68HC11 enables new high temperature designs and additionally allows 68HC11-based well logging tools and MWD tools to be upgraded for high temperature operation in deep gas reservoirs, The microcomputer chip consists of the microprocessor ALU, a small boot ROM, 4 kbyte data RAM, counter/timer unit, serial peripheral interface (SPI), asynchronous serial interface (SCI), and the A, B, C, and D parallel ports. The chip is code compatible with the single chip mode commercial 68HC11 except for the absence of the analog to digital converter system. To avoid mask programmed internal ROM, a boot program is used to load the microcomputer program from an external mask SPI ROM. A SPI RAM IC completes the chip set and allows data RAM to be added in 4 kbyte increments. The HC11 controller IC chip set is implemented in the Peregrine Semiconductor 0.5 micron Silicon-on-Sapphire (SOS) process using a custom high temperature cell library developed at Oklahoma State University. Yield data is presented for all, the HC11, SPI-RAM and ROM. The lessons learned in this project were extended to the successful development of two high temperature versions of the LEON3 and a companion 8 Kbyte SRAM, a 200 C version for the Navy and a 275 C version for the gas industry.

  7. 2750 C Downhole Microcomputer System

    International Nuclear Information System (INIS)

    Hutchens, Chris; Soo, Hooi Miin

    2008-01-01

    An HC11 controller IC and along with serial SRAM and ROM support ICs chip set were developed to support a data acquisition and control for extreme temperature/harsh environment conditions greater than 275 C. The 68HC11 microprocessor is widely used in well logging tools for control, data acquisition, and signal processing applications and was the logical choice for a downhole controller. This extreme temperature version of the 68HC11 enables new high temperature designs and additionally allows 68HC11-based well logging tools and MWD tools to be upgraded for high temperature operation in deep gas reservoirs, The microcomputer chip consists of the microprocessor ALU, a small boot ROM, 4 kbyte data RAM, counter/timer unit, serial peripheral interface (SPI), asynchronous serial interface (SCI), and the A, B, C, and D parallel ports. The chip is code compatible with the single chip mode commercial 68HC11 except for the absence of the analog to digital converter system. To avoid mask programmed internal ROM, a boot program is used to load the microcomputer program from an external mask SPI ROM. A SPI RAM IC completes the chip set and allows data RAM to be added in 4 kbyte increments. The HC11 controller IC chip set is implemented in the Peregrine Semiconductor 0.5 micron Silicon-on-Sapphire (SOS) process using a custom high temperature cell library developed at Oklahoma State University. Yield data is presented for all, the HC11, SPI-RAM and ROM. The lessons learned in this project were extended to the successful development of two high temperature versions of the LEON3 and a companion 8 Kbyte SRAM, a 200 C version for the Navy and a 275 C version for the gas industry

  8. An open microcomputer-based laboratory system for perceptional experimentality

    Science.gov (United States)

    Hamalainen, Ari

    A computer, equipped with hardware for acquiring data about the properties of a physical system and programs for processing that data, is a powerful tool for physics research and instruction. There is strong evidence that utilizing microcomputer-based laboratories (MBLs) in instruction can lead to significantly improved learning. The perceptional approach is a method for physics instruction, developed at the Department of Physics, University of Helsinki. Its main arguments are that the meanings of the concepts must be learnt before their formal definitions and adoption, and that learning and research are fundamentally similar concept formation processes. Applying the perceptional approach requires the ability to perform quantitative experiments, either as students' laboratory exercises or as lecture demonstrations, and to process their results. MBL tools are essential for this. In student's laboratory exercises, they reduce the routine work and leave more time for the actual learning. In lecture demonstrations, they make it possible to perform the experiments in the tight time limits. At a previous stage of the research, a set of requirements was found that the perceptional approach places on MBL systems. The primary goal of this thesis is to build a prototype of a MBL system that would fulfil these requirements. A secondary goal is to describe technical aspects of a computerized measurement system from the standpoint of educational use. The prototype was built using mostly commercial sensors and data acquisition units. The software was written with a visual programming language, designed for instrumentation applications. The prototype system was developed and tested with a set of demonstrations of various topics in the Finnish high school physics curriculum, which were implemented according to the perceptional approach. Limited usability tests were also performed. The prototype was improved, until it could perform the test demonstrations. It was found to meet the

  9. 'Micro-8' micro-computer system

    International Nuclear Information System (INIS)

    Yagi, Hideyuki; Nakahara, Yoshinori; Yamada, Takayuki; Takeuchi, Norio; Koyama, Kinji

    1978-08-01

    The micro-computer Micro-8 system has been developed to organize a data exchange network between various instruments and a computer group including a large computer system. Used for packet exchangers and terminal controllers, the system consists of ten kinds of standard boards including a CPU board with INTEL-8080 one-chip-processor. CPU architecture, BUS architecture, interrupt control, and standard-boards function are explained in circuit block diagrams. Operations of the basic I/O device, digital I/O board and communication adapter are described with definitions of the interrupt ramp status, I/O command, I/O mask, data register, etc. In the appendixes are circuit drawings, INTEL-8080 micro-processor specifications, BUS connections, I/O address mappings, jumper connections of address selection, and interface connections. (author)

  10. Using joined minicomputer-microcomputer systems for intricate sample and data manipulations

    International Nuclear Information System (INIS)

    Meng, J.D.

    1980-09-01

    We have produced, over the past three years, three automated x-ray fluorescence based elemental analysis systems, that combine a minicomputer and a microcomputer to perform intricate sample and data manipulations. The mini-micro combination facilitates the reuse of sizable sections of hardware and programs for different x-ray analysis projects. Each of our systems has been a step closer to an optimum general solution. The combination reaps economic benefits throughout development, fabrication and maintenance, an important consideration for designers of custom-built, one-of-a-kind data analysis systems such as these

  11. A collection and information analysis of the experiment with microcomputer

    International Nuclear Information System (INIS)

    Mohd Ariffin bin Aton; Ler Leong Tat

    1985-01-01

    A microcomputer-based system for the continuous collection and analysis of data from a fermentor is described. The system was designed around commercially available hardware and interface and software packages written for microcomputers. Additional programmes were written in BASIC to allow the results to be printed in a specific format. The data read from the fermentor were automatically stored on a floppy disc and analysis on the data can be performed at our convenience. Such method for data collection is not limited to a bioreactor, however, since instruments that require continuous accurate reading, such as GLC, HPLC, etc., could be coupled to a microcomputer system. (author)

  12. Microcomputer-controlled world time display for public area viewing

    Science.gov (United States)

    Yep, S.; Rashidian, M.

    1982-05-01

    The design, development, and implementation of a microcomputer-controlled world clock is discussed. The system, designated international Time Display System (ITDS), integrates a Geochron Calendar Map and a microcomputer-based digital display to automatically compensate for daylight savings time, leap year, and time zone differences. An in-depth technical description of the design and development of the electronic hardware, firmware, and software systems is provided. Reference material on the time zones, fabrication techniques, and electronic subsystems are also provided.

  13. A Preserved Context Indexing System for Microcomputers: PERMDEX.

    Science.gov (United States)

    Yerkey, A. Neil

    1983-01-01

    Following a discussion of derivative versus assignment indexing, use of roles, and concept behind Preserved Concept Indexing System, features of PERMDEX (microcomputer program to assist in creation of permuted printed index) are described including indexer input and prompts, the shunting algorithm, and sorting and printing routines. Fourteen…

  14. Integrating Micro-computers with a Centralized DBMS: ORACLE, SEED AND INGRES

    Science.gov (United States)

    Hoerger, J.

    1984-01-01

    Users of ADABAS, a relational-like data base management system (ADABAS) with its data base programming language (NATURAL) are acquiring microcomputers with hopes of solving their individual word processing, office automation, decision support, and simple data processing problems. As processor speeds, memory sizes, and disk storage capacities increase, individual departments begin to maintain "their own" data base on "their own" micro-computer. This situation can adversely affect several of the primary goals set for implementing a centralized DBMS. In order to avoid this potential problem, these micro-computers must be integrated with the centralized DBMS. An easy to use and flexible means for transferring logic data base files between the central data base machine and micro-computers must be provided. Some of the problems encounted in an effort to accomplish this integration and possible solutions are discussed.

  15. An automatic single channel analyzer based on single-chip microcomputer

    International Nuclear Information System (INIS)

    Yan Xuekun; Jia Mingchun; Zhang Yan; Liu Mingjian; Luo Ming

    2008-01-01

    The hardware and software of an automatic single channel analyzer based on AT89C51RC single-chip microcomputer is described in this paper. The equipment takes a method of channel-width-adjusting symmetrically, and makes use of single-chip microcomputer to control the two DAC0832 so as to adjust the discriminating threshold and channel-width automatically. As a result, the auto-measuring of the single channel analyzer is realized. Its circuit configuration is simple, and the uniformity of its channel-width is well, too. (authors)

  16. Data flow methods for dynamic system simulation - A CSSL-IV microcomputer network interface

    Science.gov (United States)

    Makoui, A.; Karplus, W. J.

    1983-01-01

    A major problem in employing networks of microcomputers for the real-time simulation of complex systems is to allocate computational tasks to the various microcomputers in such a way that idle time and time lost in interprocess communication is minimized. The research reported in this paper is directed to the development of a software interface between a higher-level simulation language and a network of microcomputers. A CSSL-IV source program is translated to a data flow graph. This graph is then analyzed automatically so as to allocate computing tasks to the various processors.

  17. Tractor performance monitor based on a single-chip microcomputer

    Energy Technology Data Exchange (ETDEWEB)

    Bedri, A.R.; Marley, S.J.; Buchelle, W.F.; Smay, T.A.

    1981-01-01

    A tractor performance monitor based on a single-chip microcomputer was developed to measure ground speed, slip, fuel consumption (rate and total), total area, theoretical time, and total time. Transducers used are presented in detail. 5 refs.

  18. The composing technique of fast and large scale nuclear data acquisition and control system with single chip microcomputers and PC computers

    International Nuclear Information System (INIS)

    Xu Zurun; Wu Shiying; Liu Haitao; Yao Yangsen; Wang Yingguan; Yang Chaowen

    1998-01-01

    The technique of employing single-chip microcomputers and PC computers to compose a fast and large scale nuclear data acquisition and control system was discussed in detail. The optimum composition mode of this kind of system, the acquisition and control circuit unit based on single-chip microcomputers, the real-time communication methods and the software composition under the Windows 3.2 were also described. One, two and three dimensional spectra measured by this system were demonstrated

  19. The composing technique of fast and large scale nuclear data acquisition and control system with single chip microcomputers and PC computers

    International Nuclear Information System (INIS)

    Xu Zurun; Wu Shiying; Liu Haitao; Yao Yangsen; Wang Yingguan; Yang Chaowen

    1997-01-01

    The technique of employing single-chip microcomputers and PC computers to compose a fast and large scale nuclear data acquisition and control system was discussed in detail. The optimum composition mode of this kind of system, the acquisition and control circuit unit based on single-chip microcomputers, the real-time communication methods and the software composition under the Windows 3.2 were also described. One, two and three dimensional spectra measured by this system were demonstrated

  20. Microcomputer data acquisition and control.

    Science.gov (United States)

    East, T D

    1986-01-01

    In medicine and biology there are many tasks that involve routine well defined procedures. These tasks are ideal candidates for computerized data acquisition and control. As the performance of microcomputers rapidly increases and cost continues to go down the temptation to automate the laboratory becomes great. To the novice computer user the choices of hardware and software are overwhelming and sadly most of the computer sales persons are not at all familiar with real-time applications. If you want to bill your patients you have hundreds of packaged systems to choose from; however, if you want to do real-time data acquisition the choices are very limited and confusing. The purpose of this chapter is to provide the novice computer user with the basics needed to set up a real-time data acquisition system with the common microcomputers. This chapter will cover the following issues necessary to establish a real time data acquisition and control system: Analysis of the research problem: Definition of the problem; Description of data and sampling requirements; Cost/benefit analysis. Choice of Microcomputer hardware and software: Choice of microprocessor and bus structure; Choice of operating system; Choice of layered software. Digital Data Acquisition: Parallel Data Transmission; Serial Data Transmission; Hardware and software available. Analog Data Acquisition: Description of amplitude and frequency characteristics of the input signals; Sampling theorem; Specification of the analog to digital converter; Hardware and software available; Interface to the microcomputer. Microcomputer Control: Analog output; Digital output; Closed-Loop Control. Microcomputer data acquisition and control in the 21st Century--What is in the future? High speed digital medical equipment networks; Medical decision making and artificial intelligence.

  1. Human engineering in the design of expert systems for microcomputer system troubleshooting

    International Nuclear Information System (INIS)

    Easter, J.R.; Elm, W.C.

    1988-01-01

    The man-machine interfaces of the first generation of expert systems have usually received little or no explicit design effort. As a result, many of these systems when placed in their productive environment have only served to collect dust. One of the more aggravating attributes of such systems has been the demand that the user of such systems religiously follow the pre-determined and fixed problem solving path the domain expert designed in the expert system. Westinghouse has embarked on a program aimed at improving the productivity of the I and C maintenance staff responsible for caring for these new systems, the focus of which is the development of a computer based expert system to be used as a trouble-shooting aid. To date, Westinghouse has created a knowledge structure for such an expert system that describes the purposes or design objectives of the faulted microcomputer system

  2. Microcomputer-aided monitor for liquid hydrogen target system

    International Nuclear Information System (INIS)

    Kitami, T.; Watanabe, K.

    1983-03-01

    A microcomputer-aided monitor for a liquid hydrogen target system has been designed and tested. Various kinds of input data such as temperature, pressure, vacuum, etc. are scanned in a given time interval. Variation with time in any four items can be displayed on CRT and, if neccessary, printed out on a sheet of recording paper. (author)

  3. Assurance program for remedial action (APRA) microcomputer-operated bibliography management system

    International Nuclear Information System (INIS)

    Stenner, R.D.; Washburn, D.K.; Denham, D.H.

    1985-10-01

    Pacific Northwest Laboratory (PNL) provided technical assistance to the Office of Operational Safety (OOS) in developing their Assurance Program for Remedial Action (APRA). The APRA Bibliography Management System (BMS), a microcomputer-operated system designed to file, locate and retrieve project-specific bibliographic data, was developed to manage the documentation associated with APRA. The BMS uses APRABASE, a PNL-developed computer program written in dBASE II language, which is designed to operate using the commercially available dBASE II database software. The paper describes the APRABASE computer program, its associated subprograms, and the dBASE II APRA file. Although the BMS was designed to manage APRA-associated documents, it could be easily adapted for use in handling bibliographic data associated with any project

  4. Assurance Program for Remedial Action (APRA) microcomputer-operated bibliography management system

    International Nuclear Information System (INIS)

    Stenner, R.D.; Washburn, D.K.; Denham, D.H.

    1986-01-01

    Pacific Northwest Laboratory (PNL) provided technical assistance to the Office of Operational Safety (OOS) in developing their Assurance Program for Remedial Action (APRA). The APRA Bibliography Management System (BMS), a microcomputer-operated system designed to file, locate and retrieve project-specific bibliographic data, was developed to manage the documentation associated with APRA. The BMS uses APRABASE, a PNL-developed computer program written in dBASE II/sup (b)/ language, which is designed to operate using the commercially available dBASE II database software. This paper describes the APRABASE computer program, its associated subprograms, and the dBASE II APRA file. Although the BMS was designed to manage APRA-associated documents, it could be easily adapted for use in handling bibliographic data associated with any project

  5. A full automatic system controlled with IBM-PC/XT micro-computer for neutron activation analysis

    International Nuclear Information System (INIS)

    Song Quanxun

    1992-01-01

    A full automatic system controlled with micro-computers for NAA is described. All processes are automatically completed with an IBM-PC/XT micro-computer. The device is stable, reliable, flexible and convenient for use and has many functions and applications in automatical analysis of long, middle and short lived nuclides. Due to a high working efficiency of the instrument and micro-computers, both time and power can be saved. This method can be applied in other nuclear analysis techniques

  6. A Low Cost Microcomputer System for Process Dynamics and Control Simulations.

    Science.gov (United States)

    Crowl, D. A.; Durisin, M. J.

    1983-01-01

    Discusses a video simulator microcomputer system used to provide real-time demonstrations to strengthen students' understanding of process dynamics and control. Also discusses hardware/software and simulations developed using the system. The four simulations model various configurations of a process liquid level tank system. (JN)

  7. Automated Developmental Disabilities Out-Patient Treatment Review System (ADDOPTRS)—Development and Automation of a Microcomputer Based Case Management System

    Science.gov (United States)

    Fisch, Clifford B.; Fisch, Martin L.

    1979-01-01

    The Stanley S. Lamm Institute for Developmental Disabilities of The Long Island College Hospital, in conjunction with Micro-Med Systems has developed a low cost micro-computer based information system (ADDOP TRS) which monitors quality of care in outpatient settings rendering services to the developmentally disabled population. The process of conversion from paper record keeping systems to direct key-to-disk data capture at the point of service delivery is described. Data elements of the information system including identifying patient information, coded and English-grammar entry procedures for tracking elements of service as well as their delivery status are described. Project evaluation criteria are defined including improved quality of care, improved productivity for clerical and professional staff and enhanced decision making capability. These criteria are achieved in a cost effective manner as a function of more efficient information flow. Administrative applications including staff/budgeting procedures, submissions for third party reimbursement and case reporting to utilization review committees are considered.

  8. Software in windows for staple compounding system of microcomputer nuclear mass scale

    International Nuclear Information System (INIS)

    Wang Yanting; Zhang Yongming; Wang Yu; Jin Dongping

    1998-01-01

    The software exploited in windows for staple compounding system of microcomputer nuclear mass scale is described. The staple compounding system is briefly narrated. The software structure and its realizing method are given

  9. Microcomputer-controlled ultrasonic data acquisition system

    International Nuclear Information System (INIS)

    Simpson, W.A. Jr.

    1978-11-01

    The large volume of ultrasonic data generated by computer-aided test procedures has necessitated the development of a mobile, high-speed data acquisition and storage system. This approach offers the decided advantage of on-site data collection and remote data processing. It also utilizes standard, commercially available ultrasonic instrumentation. This system is controlled by an Intel 8080A microprocessor. The MCS80-SDK microcomputer board was chosen, and magnetic tape is used as the storage medium. A detailed description is provided of both the hardware and software developed to interface the magnetic tape storage subsystem to Biomation 8100 and Biomation 805 waveform recorders. A boxcar integrator acquisition system is also described for use when signal averaging becomes necessary. Both assembly language and machine language listings are provided for the software

  10. Design of Water Temperature Control System Based on Single Chip Microcomputer

    Science.gov (United States)

    Tan, Hanhong; Yan, Qiyan

    2017-12-01

    In this paper, we mainly introduce a multi-function water temperature controller designed with 51 single-chip microcomputer. This controller has automatic and manual water, set the water temperature, real-time display of water and temperature and alarm function, and has a simple structure, high reliability, low cost. The current water temperature controller on the market basically use bimetal temperature control, temperature control accuracy is low, poor reliability, a single function. With the development of microelectronics technology, monolithic microprocessor function is increasing, the price is low, in all aspects of widely used. In the water temperature controller in the application of single-chip, with a simple design, high reliability, easy to expand the advantages of the function. Is based on the appeal background, so this paper focuses on the temperature controller in the intelligent control of the discussion.

  11. Serial network simplifies the design of multiple microcomputer systems

    Energy Technology Data Exchange (ETDEWEB)

    Folkes, D.

    1981-01-01

    Recently there has been a lot of interest in developing network communication schemes for carrying digital data between locally distributed computing stations. Many of these schemes have focused on distributed networking techniques for data processing applications. These applications suggest the use of a serial, multipoint bus, where a number of remote intelligent units act as slaves to a central or host computer. Each slave would be serially addressable from the host and would perform required operations upon being addressed by the host. Based on an MK3873 single-chip microcomputer, the SCU 20 is designed to be such a remote slave device. The capabilities of the SCU 20 and its use in systems applications are examined.

  12. Data acquisition and processing based on the multi-microcomputers data communication system for the physics experiments of HL-1 tokamak

    International Nuclear Information System (INIS)

    Ren Libo; Liu Aiping; Xu Wenbin; Ao Xueling; Gao Lanbin; Yan Derong

    1989-08-01

    The data acquisition and processing system and automatic monitor system based on the data communication of multimicrocomputers for the physics experiments of HL-1 tokamak are described. The data communications between microcomputers are completed with parallel and serial interfaces. The signals from Rokofski coils, single loop turn, soft X-ray absorb spectrometer, microwave interfermeter, bolometer, soft X-ray sawtooth Au-Si surface barrier detectors and magnetic probes have been acquired and processed. Plasma parameters have been obtained. Specially, the electron density profiles have been obtained for the first time, and the simulation about plasma radius, horizontal displacement, electron temperature and electron line-average density has been completed

  13. Microcomputer based shelf system to monitor special nuclear materials in storage

    International Nuclear Information System (INIS)

    Nicholson, N.; Kuckertz, T.H.; Ethridge, C.D.

    1980-01-01

    Diversion of special nuclear material has become a matter of grave concern in recent years. Large quantities of this material are kept in long-term storage and must be inventoried periodically, resulting in a time-consuming activity that exposes personnel to additional radiation. A system that provides continuous surveillance of stored special nuclear materials has been developed. A shelf monitor has been designed using a single component microcomputer to collect data from a Geiger Muller tube that monitors gamma emissions and a scale that monitors the total weight of the special nuclear material and its container. A network of these shelf monitors reports their acquired data to a minicomputer for analysis and storage. Because a large number of these monitors is likely to be needed in most storage facilities, one objective of this program has been to develop a low cost but reliable monitor

  14. Nuclear spectrum analysis by using microcomputer

    International Nuclear Information System (INIS)

    Sanyal, M.K.; Mukhopadhyay, P.K.; Rao, A.D.; Pethe, V.A.

    1984-01-01

    A method is presented for analysis of nuclear spectra by using microcomputer. A nonlinear least square fit of a mathematical model with observed spectrum is performed with variable metric method. The linear search procedure of the variable metric method has been modified so that the algorithm needs less program space and computational time both of which are important for microcomputer implementation. This widely used peak analysis method can now be made available in microcomputer based multichannel analysers. (author)

  15. JAX: a micro-computer based X-ray diffractometer controller

    International Nuclear Information System (INIS)

    Naval, P.C. Jr.

    1987-05-01

    This paper describes a micro-computer based X-ray diffractometer controller and explores its possibilities in simplifying acquisition and analysis of X-ray powder diffraction data. The interrupt-driven controller can operate in both present time and present count data acquisition modes and allows a data analysis program to execute concurrently with data collection. (Auth.). 16 figs.; 2 tabs

  16. A Laboratory Application of Microcomputer Graphics.

    Science.gov (United States)

    Gehring, Kalle B.; Moore, John W.

    1983-01-01

    A PASCAL graphics and instrument interface program for a Z80/S-100 based microcomputer was developed. The computer interfaces to a stopped-flow spectrophotometer replacing a storage oscilloscope and polaroid camera. Applications of this system are discussed, indicating that graphics and analog-to-digital boards have transformed the computer into…

  17. Microcomputer relay regulator in the CAMAC standard

    International Nuclear Information System (INIS)

    Nikolaev, V.P.

    1984-01-01

    The digital relay regulator is developed on the base of the KM001 microcomputer and KK06 controller for automatic control ob ects with transfer functions describing a broad class of systems using actuating motors (stabilitation, follow-up systems). The CAMAC relay-unit realizes the regulation law and provides the possibility to control analogous values by 8 channels

  18. A microcomputer network for the control of digitising machines

    International Nuclear Information System (INIS)

    Seller, P.

    1981-01-01

    A distributed microcomputing network operates in the Bubble Chamber Research Group Scanning Laboratory at the Rutherford and Appleton Laboratories. A microcomputer at each digitising table buffers information, controls the functioning of the table and enhances the machine/operator interface. The system consists of fourteen microcomputers together with a VAX 11/780 computer used for data analysis. These are inter-connected via a packet switched network. This paper will describe the features of the combined system, including the distributed computing architecture and the packet switched method of communication. This paper will also describe in detail a high speed packet switching controller used as a central node of the network. This controller is a multiprocessor microcomputer system with eighteen central processor units, thirty-four direct memory access channels and thirty-four prioritorised and vectored interrupt channels. This microcomputer is of general interest as a communications controller due to its totally programmable nature. (orig.)

  19. Graphic terminal based on storage tube display with microcomputer

    International Nuclear Information System (INIS)

    Leich, H.; Levchanovsky, F.; Nikulnikov, A.; Polyntsev, A.; Prikhodko, V.

    1981-01-01

    This paper describes a graphic terminal where a microcomputer realizes functions like the generation of picture elements (points, symbols, vectors), display control, processing of data received from keyboard and trackball, communication with a host computer and others. The terminal has been designed for operating in a local network as well as in autonomous control systems for data acquisition and processing in physical experiments [ru

  20. Microcomputer-Controlled Reader Systems for Archaeological and Geological TL Dating

    DEFF Research Database (Denmark)

    Bøtter-Jensen, Lars; Mejdahl, V.

    1984-01-01

    Two fully automated TL reader systems for TL dating and a manually operated reader for research purpose were put into operation during 1982-3. All systems are controlled by HP-85 or HP-86 microcomputers; thus flexibility in selection of measurement parameters, calculation of TL signals and displa...... the archaeological and geological ages. The principle of the measurement procedures are described, and dating results are presented to illustrate the performance of the systems...

  1. CC80-A microcomputer crate controller for CAMAC

    International Nuclear Information System (INIS)

    Walz, H.V.

    1976-11-01

    A microcomputer crate controller has been developed for use in CAMAC based instrumentation, control, and data processing systems at the Stanford Linear Accelerator Center. This unit may be used in multicrate branch highway systems to provide local processing capability within each crate, or in a single crate to form a stand-alone CAMAC system

  2. A microcomputer controlled, self-contained field measurement and analysis system

    International Nuclear Information System (INIS)

    Haddock, C.; Smith, G.; Mckee, J.S.C.

    1989-10-01

    Current accelerator projects will involve the construction and field measurement of up to ten thousand magnets. A statistical analysis has shown that in order to optimize the performance of an accelerator it will be necessary to measure the parameters of field strength, field uniformity and harmonic content of every magnet. If the measurements are performed at the construction site, the magnets which do not meet the required specifications can be repaired immediately. This paper describes a self-contained field measurement and analysis system, based on an IBM microcomputer, which performs all the remote control, data acquisition and data analysis functions automatically. The system is of low cost such that each manufacturer could provide field parameters on each magnet as it is completed thus avoiding a logistical problem at the accelerator site

  3. Serials Management by Microcomputer: The Potential of DBMS.

    Science.gov (United States)

    Vogel, J. Thomas; Burns, Lynn W.

    1984-01-01

    Describes serials management at Philadelphia College of Textiles and Science library via a microcomputer, a file manager called PFS, and a relational database management system called dBase II. Check-in procedures, programing with dBase II, "static" and "active" databases, and claim procedures are discussed. Check-in forms are…

  4. The development and application of a coincidence measurement apparatus with micro-computer system

    International Nuclear Information System (INIS)

    Du Hongshan; Zhou Youpu; Gao Junlin; Qin Deming; Cao Yunzheng; Zhao Shiping

    1987-01-01

    A coincidence measurement apparatus with micro-computer system is developed. Automatic data acquisition and processing are achieved. Results of its application for radioactive measurement are satisfactory

  5. Microcomputer-controlled ultrasonic data acquisition system. [LMFBR

    Energy Technology Data Exchange (ETDEWEB)

    Simpson, W.A. Jr.

    1978-11-01

    The large volume of ultrasonic data generated by computer-aided test procedures has necessitated the development of a mobile, high-speed data acquisition and storage system. This approach offers the decided advantage of on-site data collection and remote data processing. It also utilizes standard, commercially available ultrasonic instrumentation. This system is controlled by an Intel 8080A microprocessor. The MCS80-SDK microcomputer board was chosen, and magnetic tape is used as the storage medium. A detailed description is provided of both the hardware and software developed to interface the magnetic tape storage subsystem to Biomation 8100 and Biomation 805 waveform recorders. A boxcar integrator acquisition system is also described for use when signal averaging becomes necessary. Both assembly language and machine language listings are provided for the software.

  6. Five Basic Microcomputer Applications for Marketing Educators.

    Science.gov (United States)

    James, Richard F.

    The microcomputer has five basic applications in marketing education--a remedial/tutorial application, instructional purposes, simulation, the project data base, and classroom management. Examples of word processing applications of a microcomputer are updating annual training plans and producing letters to advisory committee members, parents, and…

  7. Use of microcomputers in health and social service applications in developing nations.

    Science.gov (United States)

    Bertrand, W E

    1987-01-01

    The microcomputer is creating something of a revolution in many developing nations where historically there has been a lack of access to computer power at all levels of the health sector. For the first time, practitioners and researchers, often trained in computer techniques for developing countries, have access through microcomputers to data and information manipulation in their local workplace. While the history of microcomputers in such settings is short, this article presents early evidence from several countries which indicates the usefulness of various applications. The majority of the applications reported in the literature from clinical and research laboratories is made up of national data base systems and special studies of morbidity and mortality. Secondary applications, including assistance in biographical searches and word and graphics processing, are also reviewed in this article. A summary of the most utilized microcomputer hardware configurations completes the review.

  8. Use of Data Base Microcomputer Software in Descriptive Nursing Research

    OpenAIRE

    Chapman, Judy Jean

    1985-01-01

    Data base microcomputer software was used to design a file for data storage and retrieval in a qualitative nursing research project. The needs of 50 breast feeding mothers from birth to four months were studied. One thousand records with descriptive nursing data were entered into the file. The search and retrieval capability of data base software facilitated this qualitative research. The findings will be discussed in three areas: (1) infant concerns, (2) postpartum concerns, and (3) breast c...

  9. The application and development on radiation monitoring microcomputer management system in design of a certain project

    International Nuclear Information System (INIS)

    Zhang Hongyou

    1993-01-01

    A scheme of a radiation monitoring system with a RMMMS (Radiation Monitoring Microcomputer Management System) has been designed for the first time in the radiation protection design of a certain nuclear projection undertaken by the BINE (Beijing Institute of Nuclear Engineering). Meanwhile, we accepted the research task of the RMMMS that can manage 40 monitoring channel. The key factors of radiation monitors, microcomputer, information management and systematic design method are considered in the development of the RMMMS. This paper presents briefly the scheme and functions of the RMMMS

  10. Microcomputer Applications in Local Assessment Systems.

    Science.gov (United States)

    Harnisch, Delwyn L.; And Others

    The capabilities and hardware requirements of four microcomputer software packages produced by the Office of Educational Testing, Research and Service at the University of Illinois at Urbana-Champaign are described. These programs are: (1) the Scan-Tron Forms Analysis Package Version 2.0, an interface between an IBM-compatible and a Scan-Tron…

  11. Development of a VME and CAMAC based data acquisition and transfer system for JT-60 control

    International Nuclear Information System (INIS)

    Totsuka, Toshiyuki

    1993-08-01

    Development of a VME and CAMAC based data acquisition and transfer system for JT-60 Control is reported. The present data acquisition and transfer system in JT-60 control is basically composed of CAMAC devices. Since the system equipped with 16-bit microcomputers was manufactured more than ten years ago, the performance and program development environment of the system are apparently worse than those of modern 32-bit microcomputers. To improve these disadvantages, a new data acquisition and transfer system using VME-based 32-bit microcomputers and CAMAC drivers is under design. Corresponding to this design, a CAMAC handler, which runs on the microcomputer, for the VME based CAMAC driver was newly developed. Moreover, the functions of the driver and data transfer performance of the VME and CAMAC complex system were tested. The test results shown that the VME based microcomputer and CAMAC serial driver can be applied for the fast and reliable acquisition and transfer system for JT-60 control. (author)

  12. Micro-computer control for super-critical He generation

    International Nuclear Information System (INIS)

    Tamada, Noriharu; Sekine, Takehiro; Tomiyama, Sakutaro

    1979-01-01

    The development of a large scale refrigeration system is being stimulated by new superconducting techniques representated by a superconducting power cable and a magnet. For the practical operation of such a large system, an automatic control system with a computer is required, because it can attain an effective and systematic operation. For this reason, we examined and developed micro-computer control techniques for supercritical He generation, as a simplified control model of the refrigeration system. The experimental results showed that the computer control system can attain fine controlability, even if the control element is only one magnetic valve, but a BASIK program language of micro-computer, which is convinient and generaly used, isn't enough one to control a more complicated system, because of its low calculating speed. Then we conclude that a more effective program language for micro-computer must be developed to realize practical refrigeration control. (author)

  13. A distributed microcomputer-controlled system for data acquisition and power spectral analysis of EEG.

    Science.gov (United States)

    Vo, T D; Dwyer, G; Szeto, H H

    1986-04-01

    A relatively powerful and inexpensive microcomputer-based system for the spectral analysis of the EEG is presented. High resolution and speed is achieved with the use of recently available large-scale integrated circuit technology with enhanced functionality (INTEL Math co-processors 8087) which can perform transcendental functions rapidly. The versatility of the system is achieved with a hardware organization that has distributed data acquisition capability performed by the use of a microprocessor-based analog to digital converter with large resident memory (Cyborg ISAAC-2000). Compiled BASIC programs and assembly language subroutines perform on-line or off-line the fast Fourier transform and spectral analysis of the EEG which is stored as soft as well as hard copy. Some results obtained from test application of the entire system in animal studies are presented.

  14. ICH rf system data acquisition and real time control using a microcomputer system

    International Nuclear Information System (INIS)

    Cary, W.P.; Allen, J.A.; Pinsker, R.I.; Petty, C.C.

    1993-10-01

    On the basis of the rapidly increasing power, speed, and decreasing cost of the personal computer (microcomputer) it was felt that a real time data acquisition and control system could be configured quickly and very cost effectively. It was further felt that by using a high level or object-oriented programming language that considerable time and expense could be saved and at the same time increase system flexibility. This paper will attempt to address the desired system requirements and performance for both the control of the high power transmitters and for the data acquisition and presentation of the information

  15. On-line pressurizer surveillance system design to prevent small break LOCA through PORV using micro-computer

    International Nuclear Information System (INIS)

    Lee, Jong-Ho; Chang, Soon-Heung

    1986-01-01

    Small break LOCA caused by a stuck-open PORV is one of the important contributors to nuclear power plant risk. This paper deals with the design of a pressurizer surveillance system using micro-computer to prevent the malfunction of system and has assessed the effect of this improvement through Probabilistic Risk Assessment (PRA) method. Micro-computer diagnoses the malfunction of system by a process checking method and performs automatically backup action related to each malfunction. Owing to this improvement, we can correctly diagnose ''Spurious Opening'', ''Fail to Reclose'' and ''Small break LOCA'' which are difficult for operator to diagnose quickly and correctly and reduce the probability of a human error by an automatic backup action. (author)

  16. Development of based on 89S51 single-chip microcomputer electronic dosimeter

    International Nuclear Information System (INIS)

    Wang Junhua; Zhou Jiachao; Sun Jianghan; Du Xiao

    2009-01-01

    It describes the main design features and basic properties of based on 89S51 single-chip microcomputer electronic dosimeter with wide range and multi purposes. The dosimeter can display dose rate or accumulative dose or the maximum dose rate, record accumulative dose, the maximum dose rate and classes. (authors)

  17. Fault tolerant microcomputer based alarm annunciator for Dhruva reactor

    International Nuclear Information System (INIS)

    Chandra, A.K.

    1988-01-01

    The Dhruva alarm annunciator displays the status of 624 alarm points on an array of display windows using the standard ringback sequence. Recognizing the need for a very high availability, the system is implemented as a fault tolerant configuration. The annunciator is partitioned into three identical units; each unit is implemented using two microcomputers wired in a hot standby mode. In the event of one computer malfunctioning, the standby computer takes over control in a bouncefree transfer. The use of microprocessors has helped built-in flexibility in the system. The system also provides built-in capability to resolve the sequence of occurrence of events and conveys this information to another system for display on a CRT. This report describes the system features, fault tolerant organisation used and the hardware and software developed for the annunciation function. (author). 8 figs

  18. Microcomputer-based artificial vision support system for real-time image processing for camera-driven visual prostheses

    Science.gov (United States)

    Fink, Wolfgang; You, Cindy X.; Tarbell, Mark A.

    2010-01-01

    It is difficult to predict exactly what blind subjects with camera-driven visual prostheses (e.g., retinal implants) can perceive. Thus, it is prudent to offer them a wide variety of image processing filters and the capability to engage these filters repeatedly in any user-defined order to enhance their visual perception. To attain true portability, we employ a commercial off-the-shelf battery-powered general purpose Linux microprocessor platform to create the microcomputer-based artificial vision support system (μAVS2) for real-time image processing. Truly standalone, μAVS2 is smaller than a deck of playing cards, lightweight, fast, and equipped with USB, RS-232 and Ethernet interfaces. Image processing filters on μAVS2 operate in a user-defined linear sequential-loop fashion, resulting in vastly reduced memory and CPU requirements during execution. μAVS2 imports raw video frames from a USB or IP camera, performs image processing, and issues the processed data over an outbound Internet TCP/IP or RS-232 connection to the visual prosthesis system. Hence, μAVS2 affords users of current and future visual prostheses independent mobility and the capability to customize the visual perception generated. Additionally, μAVS2 can easily be reconfigured for other prosthetic systems. Testing of μAVS2 with actual retinal implant carriers is envisioned in the near future.

  19. A nanotube-based field emission x-ray source for microcomputed tomography

    International Nuclear Information System (INIS)

    Zhang, J.; Cheng, Y.; Lee, Y.Z.; Gao, B.; Qiu, Q.; Lin, W.L.; Lalush, D.; Lu, J.P.; Zhou, O.

    2005-01-01

    Microcomputed tomography (micro-CT) is a noninvasive imaging tool commonly used to probe the internal structures of small animals for biomedical research and for the inspection of microelectronics. Here we report the development of a micro-CT scanner with a carbon nanotube- (CNT-) based microfocus x-ray source. The performance of the CNT x-ray source and the imaging capability of the micro-CT scanner were characterized

  20. The development of the microcomputer controlling system for micro uranium on-line analyser

    CERN Document Server

    Ye Guo Qiang

    2002-01-01

    The author presents the microcomputer controlling system for micro uranium on-line analyser under Windows 3.2 system (Chinese). The user program is designed with Visual Basic 4.0, the program of controlling the hardware interface with Windows Dynamic Linking Library (DLL) which is programmed by Borland C sup + sup + 4.5, and the date processing is with Access 2.0 database

  1. Implementation of a microcomputer based distance relay for parallel transmission lines

    International Nuclear Information System (INIS)

    Phadke, A.G.; Jihuang, L.

    1986-01-01

    Distance relaying for parallel transmission lines is a difficult application problem with conventional phase and ground distance relays. It is known that for cross-country faults involving dissimilar phases and ground, three phase tripping may result. This paper summarizes a newly developed microcomputer based relay which is capable of classifying the cross-country fault correctly. The paper describes the principle of operation and results of laboratory tests of this relay

  2. Microcomputers "Goto" School.

    Science.gov (United States)

    Piele, Donald T.

    This paper is a report of a pilot project in which a microcomputer was placed in a sixth grade classroom for eight weeks for the purpose of developing logical thinking skills. Students were first given instruction on how to program the APPLE II microcomputer to draw color graphics designs; they were then given similar problems to solve using the…

  3. Use of microcomputers for planning and managing silviculture habitat relationships.

    Science.gov (United States)

    B.G. Marcot; R.S. McNay; R.E. Page

    1988-01-01

    Microcomputers aid in monitoring, modeling, and decision support for integrating objectives of silviculture and wildlife habitat management. Spreadsheets, data bases, statistics, and graphics programs are described for use in monitoring. Stand growth models, modeling languages, area and geobased information systems, and optimization models are discussed for use in...

  4. ENPEP and the microcomputer version of WASP-III: Overview and recent experience

    International Nuclear Information System (INIS)

    Buehring, W.A.; Wolsko, T.D.

    1987-01-01

    Argonne National Laboratory (ANL) has developed a microcomputer-based energy planning package entitled ENergy and Power Evaluation Program (ENPEP). It consists of seven technical modules, four commercial software packages, and an executive system that conveniently integrates the many options associated with performing energy studies. The seven technical modules and their functions are as follows: MACRO allows the user to specify macroeconomic growth (global or sectoral) that will be the drivers of energy demand. DEMAND projects energy demand based upon the macroeconomic growth information supplied in MACRO. PLANTDATA provides a library of technical data on electric generating plants that is used by BALANCE and ELECTRIC. BALANCE computes marketplace energy supply/demand balances over the study period. LOAD computes detailed electric load forecast information for use in ELECTRIC. ELECTRIC, the microcomputer (PC) version of WASP-III, calculates a minimum cost electric supply system to meet electric demand and reliability goals. IMPACTS calculates environmental impacts and resource requirements associated with energy supply system options. ENPEP provides the potential for energy planners in developing countries to carry out important studies without access to inconvenient and/or expensive mainframe computers. The ELECTRIC module of ENPEP provides electric system planners the opportunity to use the WASP-III model for expansion planning of electrical generating systems. Extensive efforts have been made in converting WASP-III to the microcomputer to provide user-friendly data entry forms and options for operations. (author). 3 refs, 20 figs

  5. Microcomputed tomography-based assessment of retrieved dental implants

    NARCIS (Netherlands)

    Narra, N.; Antalainen, A.K.; Zipprich, H.; Sándor, G.K.; Wolff, J.

    2015-01-01

    Purpose: The aim of this study was to demonstrate the potential of microcomputed tomography (micro-CT) technology in the assessment of retrieved dental implants. Cases are presented to illustrate the value of micro-CT imaging techniques in determining possible mechanical causes for dental implant

  6. Construction of Eh-pH and other stability diagrams of uranium in a multicomponent system with a microcomputer

    International Nuclear Information System (INIS)

    Haung, H.; Cuentas, L.

    1989-01-01

    Stability diagrams for a multicomponent system in aqueous chemistry provide important information for hydrometallurgy, corrosion science, geochemistry and environmental science. Two distinct types of diagrams constructed are predominance diagrams and distribution diagrams. The ability to construct stability diagrams easily, quickly and accurately is most helpful in research and development and in academic programs. The use of a microcomputer is handicapped by slow speed and limited memory. Developing program methods that promote easy calculation and plot the diagram directly on a CRT or a plotter is a primary concern. As presented in this paper, the calculation of equilibrium and boundary constraints, combined with isolation of stability areas, works well for constructing predominance diagrams. Equilibrium constraints can be obtained based on free energies of formation. Boundary constraints for the ligand component are the boundary of the diagram, and constraints for the main component are the surrounding lines of each dominant ligand. Other considerations regarding the chemical model, mathematics computation and the use of microcomputers pertaining to diagram construction are discussed. The uranium in a multicomponent system is used for demonstration

  7. An integrated computer design environment for the development of micro-computer critical software

    International Nuclear Information System (INIS)

    De Agostino, E.; Massari, V.

    1986-01-01

    The paper deals with the development of micro-computer software for Nuclear Safety System. More specifically, it describes an experimental work in the field of software development methodologies to be used for the implementation of micro-computer based safety systems. An investigation of technological improvements that are provided by state-of-the-art integrated packages for micro-based systems development has been carried out. The work has aimed to assess a suitable automated tools environment for the whole software life-cycle. The main safety functions, as DNBR, KW/FT, of a nuclear power reactor have been implemented in a host-target approach. A prototype test-bed microsystem has been implemented to run the safety functions in order to derive a concrete evaluation on the feasibility of critical software according to new technological trends of ''Software Factories''. (author)

  8. Evaluation of Root Canal Preparation Using Rotary System and Hand Instruments Assessed by Micro-Computed Tomography

    Science.gov (United States)

    Stavileci, Miranda; Hoxha, Veton; Görduysus, Ömer; Tatar, Ilkan; Laperre, Kjell; Hostens, Jeroen; Küçükkaya, Selen; Muhaxheri, Edmond

    2015-01-01

    Background Complete mechanical preparation of the root canal system is rarely achieved. Therefore, the purpose of this study was to evaluate and compare the root canal shaping efficacy of ProTaper rotary files and standard stainless steel K-files using micro-computed tomography. Material/Methods Sixty extracted upper second premolars were selected and divided into 2 groups of 30 teeth each. Before preparation, all samples were scanned by micro-computed tomography. Thirty teeth were prepared with the ProTaper system and the other 30 with stainless steel files. After preparation, the untouched surface and root canal straightening were evaluated with micro-computed tomography. The percentage of untouched root canal surface was calculated in the coronal, middle, and apical parts of the canal. We also calculated straightening of the canal after root canal preparation. Results from the 2 groups were statistically compared using the Minitab statistical package. Results ProTaper rotary files left less untouched root canal surface compared with manual preparation in coronal, middle, and apical sector (protary techniques completely prepared the root canal, and both techniques caused slight straightening of the root canal. PMID:26092929

  9. Microcomputer Intelligence for Technical Training (MITT): The evolution of an intelligent tutoring system

    Science.gov (United States)

    Norton, Jeffrey E.; Wiederholt, Bradley J.; Johnson, William B.

    1990-01-01

    Microcomputer Intelligence for Technical Training (MITT) uses Intelligent Tutoring System (OTS) technology to deliver diagnostic training in a variety of complex technical domains. Over the past six years, MITT technology has been used to develop training systems for nuclear power plant diesel generator diagnosis, Space Shuttle fuel cell diagnosis, and message processing diagnosis for the Minuteman missile. Presented here is an overview of the MITT system, describing the evolution of the MITT software and the benefits of using the MITT system.

  10. Assessing Functional Vision Using Microcomputers.

    Science.gov (United States)

    Spencer, Simon; Ross, Malcolm

    1989-01-01

    The paper describes a software system which uses microcomputers to aid in the assessment of functional vision in visually impaired students. The software also aims to be visually stimulating and to develop hand-eye coordination, visual memory, and cognitive abilities. (DB)

  11. Microcomputer Applications for Library Instruction: Automation of Test and Assignment Scoring, and Student Record Keeping.

    Science.gov (United States)

    Sugranes, Maria R.; Snider, Larry C.

    1985-01-01

    Describes the development of an automated library instruction records management system using microcomputer technology. Development described includes assessment of need, exploration of options, system design, and operational development. System products are identified and operational results are reported based on actual system performance.…

  12. Sketching with a microcomputer

    DEFF Research Database (Denmark)

    Jacobi, P.

    This report describes the use of a microcomputer as a tool for the sketch design phase of the building process. A housing development scheme comprising 175 dwellings is chosen for illustrating the procedures. Here the microcomputer is utilized for analysing the landscape, for the three-dimensiona...

  13. Trend Analysis Using Microcomputers.

    Science.gov (United States)

    Berger, Carl F.

    A trend analysis statistical package and additional programs for the Apple microcomputer are presented. They illustrate strategies of data analysis suitable to the graphics and processing capabilities of the microcomputer. The programs analyze data sets using examples of: (1) analysis of variance with multiple linear regression; (2) exponential…

  14. X-γ dose rate continuous monitor with wide range based on single-chip microcomputer

    International Nuclear Information System (INIS)

    Wu Debo; Ling Qiu; Guo Lanying; Yang Binhua

    2007-01-01

    This paper describes a concept about circuit designing of X-γ dose rate continuous monitor with wide range based on single-chip microcomputer, and also presents the design procedure of hardware and software, and gives several methods for solving the design procedure of hardware and software with emphasis. (authors)

  15. Microcomputer-based workforce scheduling for hospital porters.

    Science.gov (United States)

    Lin, C K

    1999-01-01

    This paper focuses on labour scheduling for hospital porters who are the major workforce providing routine cleansing of wards, transportation and messenger services. Generating an equitable monthly roster for porters while meeting the daily minimum demand is a tedious task scheduled manually by a supervisor. In considering a variety of constraints and goals, a manual schedule was usually produced in seven to ten days. To be in line with the strategic goal of scientific management of an acute care regional hospital in Hong Kong, a microcomputer-based algorithm was developed to schedule the monthly roster. The algorithm, coded in Digital Visual Fortran 5.0 Professional, could generate a monthly roster in seconds. Implementation has been carried out since September 1998 and the results proved to be useful to hospital administrators and porters. This paper discusses both the technical and human issues involved during the computerization process.

  16. Evaluation of Root Canal Preparation Using Rotary System and Hand Instruments Assessed by Micro-Computed Tomography.

    Science.gov (United States)

    Stavileci, Miranda; Hoxha, Veton; Görduysus, Ömer; Tatar, Ilkan; Laperre, Kjell; Hostens, Jeroen; Küçükkaya, Selen; Muhaxheri, Edmond

    2015-06-20

    Complete mechanical preparation of the root canal system is rarely achieved. Therefore, the purpose of this study was to evaluate and compare the root canal shaping efficacy of ProTaper rotary files and standard stainless steel K-files using micro-computed tomography. Sixty extracted upper second premolars were selected and divided into 2 groups of 30 teeth each. Before preparation, all samples were scanned by micro-computed tomography. Thirty teeth were prepared with the ProTaper system and the other 30 with stainless steel files. After preparation, the untouched surface and root canal straightening were evaluated with micro-computed tomography. The percentage of untouched root canal surface was calculated in the coronal, middle, and apical parts of the canal. We also calculated straightening of the canal after root canal preparation. Results from the 2 groups were statistically compared using the Minitab statistical package. ProTaper rotary files left less untouched root canal surface compared with manual preparation in coronal, middle, and apical sector (p<0.001). Similarly, there was a statistically significant difference in root canal straightening after preparation between the techniques (p<0.001). Neither manual nor rotary techniques completely prepared the root canal, and both techniques caused slight straightening of the root canal.

  17. Multiple-User Microcomputer Technology and Its Application to the Library Environment.

    Science.gov (United States)

    McCarthy, Cathleen D.

    1987-01-01

    Demonstrates the ways in which multiuser and multitasking microcomputer systems can be used for the automation of small- to medium-sized library operations. The possibilities afforded by the IBM-PC AT microcomputer are discussed and a sample configuration with estimated cost projections is provided. (EM)

  18. Doing Physics with Microcomputers.

    Science.gov (United States)

    Bak, Per

    1983-01-01

    Describes how microcomputers can perform very demanding/large-scale physics calculations at speeds not much slower than those of modern, full-size computers. Among the examples provided are a Monte Carlo simulation of the three-dimensional Ising model and a program (for the Apple microcomputer) using the time-independent Schrodinger Equation. (JN)

  19. An automated microcomputer-controlled system for neutron activation and gamma-ray spectroscopy

    International Nuclear Information System (INIS)

    Edward, J.B.; Bennett, L.G.I.

    1990-01-01

    An automated instrumental neutron activation analysis (INAA) system has been constructed at the SLOWPOKE-2 reactor at the Royal Military College of Canada (RMC). Its pneumatic transfer system is controlled by an Apple IIe computer, linked in turn to an MS-DOS-compatible microcomputer which controls data acquisition. Custom software has been created for these computers and for off-line spectral analysis using programs that incorporate either peak boundary or Gaussian peak fitting methods of analysis. This system provides the gamut of INAA techniques for the analyst. The design and performance of the hardware and software are discussed. (orig.)

  20. Structural design of SBWR reactor building complex using microcomputers

    International Nuclear Information System (INIS)

    Mandagi, K.; Rajagopal, R.S.; Sawhney, P.S.; Gou, P.F.

    1993-01-01

    The design concept of Simplified Boiling Water Reactor (SBWR) plant is based on simplicity and passive features to enhance safety and reliability, improve performance, and increase economic viability. The SBWR utilizes passive systems such as Gravity Driven Core-Cooling System (GDCS) and Passive Containment Cooling System (PCCS). To suit these design features the Reactor Building (RB) complex of the SBWR is configured as an integrated structure consisting of a cylindrical Reinforced Concrete Containment Vessel (RCCV) surrounded by square reinforced concrete safety envelope and outer box structures, all sharing a common reinforced concrete basemat. This paper describes the structural analysis and design aspects of the RB complex. A 3D STARDYNE finite element model has been developed for the structural analysis of the complex using a PC Compaq 486/33L microcomputer. The structural analysis is performed for service and factored load conditions for the applicable loading combinations. The dynamic responses of containment structures due to pool hydrodynamic loads have been calculated by an axisymmetric shell model using COSMOS/M program. The RCCV is designed in accordance with ASME Section 3, Division 2 Code. The rest of the RB which is classified as Seismic Category 1 structure is designed in accordance with the ACI 349 Code. This paper shows that microcomputers can be efficiently used for the analysis and design of large and complex structures such as RCCV and Reactor Building complex. The use of microcomputers can result in significant savings in the computational cost compared with that of mainframe computers

  1. Application of microcomputer in automating microscope measurements in nuclear emulsion viewing

    International Nuclear Information System (INIS)

    Blaho, D.

    1985-01-01

    Microcomputer system MPS 8010 is described as applied to the automation of data collection and control of a microscope. The data on the measured coordinates of the microscope are recorded on paper tape and listed on a typewriter. The microcomputer system also makes possible automatic control of the microscope position by means of stepping motors according to the value read-out of the paper tape. (author)

  2. A numerical integration approach suitable for simulating PWR dynamics using a microcomputer system

    International Nuclear Information System (INIS)

    Zhiwei, L.; Kerlin, T.W.

    1983-01-01

    It is attractive to use microcomputer systems to simulate nuclear power plant dynamics for the purpose of teaching and/or control system design. An analysis and a comparison of feasibility of existing numerical integration methods have been made. The criteria for choosing the integration step using various numerical integration methods including the matrix exponential method are derived. In order to speed up the simulation, an approach is presented using the Newton recursion calculus which can avoid convergence limitations in choosing the integration step size. The accuracy consideration will dominate the integration step limited. The advantages of this method have been demonstrated through a case study using CBM model 8032 microcomputer to simulate a reduced order linear PWR model under various perturbations. It has been proven theoretically and practically that the Runge-Kutta method and Adams-Moulton method are not feasible. The matrix exponential method is good at accuracy and fairly good at speed. The Newton recursion method can save 3/4 to 4/5 time compared to the matrix exponential method with reasonable accuracy. Vertical Barhis method can be expanded to deal with nonlinear nuclear power plant models and higher order models as well

  3. The Medical Gopher — A Microcomputer Based Physician Work Station

    Science.gov (United States)

    McDonald, Clement J.

    1984-01-01

    We've developed a microcomputer medical work station intended to reduce the physician's “gopher” work of fetching, reviewing, organizing and writing that consumes his day. The system requires extensive physician interaction; so we have developed a fast and consistent menu-oriented user interface. It provides facilities for entering prescriptions, orders, problems and other medical record information and for generating flowsheets, executing reminder rules, providing ad hoc retrievals and reporting facts about drugs, tests and differential diagnoses. Each work station is connected to a central server (currently a VAX 117/80) in a network configuration, but carries all of its own programs, tables and medical records for a few hundred patients, locally. This system is tested but not yet tried. Questions remain about physician's acceptance and the true usefullness of such a work station.

  4. Microcomputer Competencies for Vocational Teachers.

    Science.gov (United States)

    Roth, Gene L.; Tesolowski, Dennis G.

    1984-01-01

    This joint research and development project of two state departments of education used the DACUM (Developing a Curriculum) process to identify microcomputer competencies for vocational instructors. Brainstorming techniques were used to identify five categories of microcomputer applications and to determine which competencies belonged in each…

  5. Temperature measuring system based on ADuC812 MCU

    International Nuclear Information System (INIS)

    Zhou Dongmei; Ge Liangquan; Cheng Feng; Li Jinfeng

    2009-01-01

    This paper introduces a temperature measuring system which is composed of a single chip microcomputer ADuC812, new type digital temperature sensor TMP100,LED display circuit and based on I 2 C bus. I 2 C bus which is invented by PHILIPS company needs only two signal lines (SDA, SCL), can realized perfect duplex synchronous data transmission. Using the method of hardware setting of device address, can completely avoid the disadvantages of device selection addressing, thus can make hardware system has simplifier and more flexible extension method. The key part of the system is composed of a single chip microcomputer ADuC812 which is compatible with MCS-51 and is invented by AD company in america. The software is compiled with 8051 assembly language. The data acquisitin single chip microcomputer measurement system with I 2 C bus fully shows the features of flexibility, precise and high integration. Proposed high accuracy measurement method to realize environment temperature measure. (authors)

  6. Microcomputer generated pipe support calculations

    International Nuclear Information System (INIS)

    Hankinson, R.F.; Czarnowski, P.; Roemer, R.E.

    1991-01-01

    The cost and complexity of pipe support design has been a continuing challenge to the construction and modification of commercial nuclear facilities. Typically, pipe support design or qualification projects have required large numbers of engineers centrally located with access to mainframe computer facilities. Much engineering time has been spent repetitively performing a sequence of tasks to address complex design criteria and consolidating the results of calculations into documentation packages in accordance with strict quality requirements. The continuing challenges of cost and quality, the need for support engineering services at operating plant sites, and the substantial recent advances in microcomputer systems suggested that a stand-alone microcomputer pipe support calculation generator was feasible and had become a necessity for providing cost-effective and high quality pipe support engineering services to the industry. This paper outlines the preparation for, and the development of, an integrated pipe support design/evaluation software system which maintains all computer programs in the same environment, minimizes manual performance of standard or repetitive tasks, and generates a high quality calculation which is consistent and easily followed

  7. Creating, Storing, and Dumping Low and High Resolution Graphics on the Apple IIe Microcomputer System.

    Science.gov (United States)

    Fletcher, Richard K., Jr.

    This description of procedures for dumping high and low resolution graphics using the Apple IIe microcomputer system focuses on two special hardware configurations that are commonly used in schools--the Apple Dot Matrix Printer with the Apple Parallel Interface Card, and the Imagewriter Printer with the Apple Super Serial Interface Card. Special…

  8. The Microcomputer in the Clinical Nursing Research Unit

    Science.gov (United States)

    Schwirian, Patricia M.; Byers, Sandra R.

    1982-01-01

    This paper discusses the microcomputer in clinical nursing research. There are six general areas in which computers have been useful to nurses: nursing notes and charting; patient care plans; automated monitoring of high-tech nursing units; HIS and MIS systems; personnel distribution systems; and education. Three alternative models for the conduct of clinical nursing research in a hospital are described. The first is a centralized model relying on the bureaucratic structure of the hospital. Second is a decentralized network of professional nurses and research support personnel woven together by a Clinical Nurse Researcher, and third is a dedicated clinical nursing research unit. Microcomputers have five characteristics which make them vital tools for nurse researchers: user-friendliness; environment friendliness; low cost; ease of interface with other information systems; and range and quality of software.

  9. An automated x-ray stress measurement system using a microcomputer

    International Nuclear Information System (INIS)

    Kurita, Masanori; Miyagawa, Matsuo; Sato, Fumiyoshi; Sugiharai, Shigeru; Ishii, Masami; Sumiyoshi, Michio.

    1985-01-01

    An automated system for a rapid and precise X-ray stress measurement using a microcomputer has been developed. A block diagram of the system and a flowchart for the stress measurement method are shown. Of the various methods, the one most suitable for the material to be measured can be programmed in this system. The residual stress in a hardened steel having a broad diffraction profile (half-width of 7.2 deg ) could be measured in six minutes with a small standard deviation of 13 MPa by the Gaussian curve method using the sin 2 ψ method. Both the oscillation and the fixed ψ methods, using the Gaussian curve method, allow the X-ray stress measurement of coarse-grained steels; the sin 2 ψ diagram obtained by these methods had a good linearity. The residual stress measurement of an annealed chromium powder gave almost zero stress values, -3.2 to 2.9 MPa depending on the method used, showing a high accuracy of the system. (author)

  10. Graphics of (X,Y) spectrum for microcomputer

    International Nuclear Information System (INIS)

    Macias B, L.R.

    1991-08-01

    When carrying out diffraction works is frequently required to visualize the spectra of the data obtained in order to analyzing them. The design for the obtaining of data in the neutron diffractometer by means of the microcomputer allows to store them in a file by means of the one which transferring to the CYBER system so that by means of its utilities the mentioned spectrum is observed in a graph. In diffraction works, it is sought to study crystalline materials by means of the execution of the Bragg law by that the mounted sample on the diffractometer is subjected to a scanning of the sample with a radiation of a well-known wavelength and this way varying the angles, the corresponding interplanar distances are determined. The main objective of this work, is starting of a data set generated by the diffractometer, to generate the graph of the corresponding (X,Y) spectra in visual form in the screen of a microcomputer and if it is required, to obtain the graph in printed form by means of the same computer program for microcomputer. (Author)

  11. The Role of Microcomputer-Based Laboratories in Learning To Make Graphs of Distance and Velocity.

    Science.gov (United States)

    Brasell, Heather

    Two questions about the effects of microcomputer-based laboratory (MBL) activities on graphing skills were addressed in this study: (1) the extent to which activities help students link their concrete experiences with motion with graphic representations of these experiences; and (2) the degree of importance of the real-time aspect of the MBL in…

  12. [Microcomputer control of a LED stimulus display device].

    Science.gov (United States)

    Ohmoto, S; Kikuchi, T; Kumada, T

    1987-02-01

    A visual stimulus display system controlled by a microcomputer was constructed at low cost. The system consists of a LED stimulus display device, a microcomputer, two interface boards, a pointing device (a "mouse") and two kinds of software. The first software package is written in BASIC. Its functions are: to construct stimulus patterns using the mouse, to construct letter patterns (alphabet, digit, symbols and Japanese letters--kanji, hiragana, katakana), to modify the patterns, to store the patterns on a floppy disc, to translate the patterns into integer data which are used to display the patterns in the second software. The second software package, written in BASIC and machine language, controls display of a sequence of stimulus patterns in predetermined time schedules in visual experiments.

  13. Data processing with PC-9801 micro-computer for HCN laser scattering experiments

    International Nuclear Information System (INIS)

    Iwasaki, T.; Okajima, S.; Kawahata, K.; Tetsuka, T.; Fujita, J.

    1986-09-01

    In order to process the data of HCN laser scattering experiments, a micro-computer software has been developed and applied to the measurements of density fluctuations in the JIPP T-IIU tokamak plasma. The data processing system consists of a spectrum analyzer, SM-2100A Signal Analyzer (IWATSU ELECTRIC CO., LTD.), PC-9801m3 micro-computer, a CRT-display and a dot-printer. The output signals from the spectrum analyzer are A/D converted, and stored on a mini-floppy-disk equipped to the signal analyzer. The software to process the data is composed of system-programs and several user-programs. The real time data processing is carried out for every shot of plasma at 4 minutes interval by the micro-computer connected with the signal analyzer through a GP-IB interface. The time evolutions of the frequency spectrum of the density fluctuations are displayed on the CRT attached to the micro-computer and printed out on a printer-sheet. In the case of the data processing after experiments, the data stored on the floppy-disk of the signal analyzer are read out by using a floppy-disk unit attached to the micro-computer. After computation with the user-programs, the results, such as monitored signal, frequency spectra, wave number spectra and the time evolutions of the spectrum, are displayed and printed out. In this technical report, the system, the software and the directions for use are described. (author)

  14. Software development assurance for special control computer sets on the base of the Electronica-60M microcomputer in the stations of fuel element nondestructive testing

    International Nuclear Information System (INIS)

    Vasil'kova, A.D.; Grachev, S.N.; Salakatova, L.S.

    1987-01-01

    A special computational control complex (SCCC) including the ''Elektronika-60M'' microcomputer, a device for communication with an object (DCO) based on the typical microprocessing set (TMS) based on LIUS-2 KTS means and an adapter for communication of the ''Elektronika-60M'' microcomputer bus with IK1 TMS bus developed for their conjugation is used for development of nondestructive control post software. An instrumental SCCC including SM-4 microcomputer, TMS units as DCO, an adapter for communication of the common bus of the SM-4 minicomputer with the IK1 TMS bus developed for their conjugation and devices for simulation of the facility operation is suggested to increase labour productivity of programmers. The SM-4 microcomputer permits to develop programs in the FORTRAN language and to carry out their effective adjustment. A subprogram library for communication with TMS units is compiled, and the technique for testing FORTRAN programs in programmable read-only memory TMS as well as start of these programs are developed

  15. Digital TV-echelle spectrograph for simultaneous multielemental analysis using microcomputer control

    International Nuclear Information System (INIS)

    Davidson, J.B.; Case, A.L.

    1980-12-01

    A digital TV-echelle spectrograph with microcomputer control was developed for simultaneous multielemental analysis. The optical system is a commercially available unit originally equipped for film and photomultiplier (single element) readout. The film port was adapted for the intensifier camera. The camera output is digitized and stored in a microcomputer-controlled, 512 x 512 x 12 bit memory and image processor. Multiple spectra over the range of 200 to 800 nm are recorded in a single exposure. Spectra lasting from nanoseconds to seconds are digitized and stored in 0.033 s and displayed on a TV monitor. An inexpensive microcomputer controls the exposure, reads and displays the intensity of predetermined spectral lines, and calculates wavelengths of unknown lines. The digital addresses of unknown lines are determined by superimposing a cursor on the TV display. The microcomputer also writes into memory wavelength fiducial marks for alignment of the TV camera

  16. Designing a User-Friendly Microcomputer-Based Laboratory Package through the Factor Analysis of Teacher Evaluations

    Science.gov (United States)

    Lavonen, Jari; Juuti, Kalle; Meisalo, Veijo

    2003-01-01

    In this study we analyse how the experiences of chemistry teachers on the use of a Microcomputer-Based Laboratory (MBL), gathered by a Likert-scale instrument, can be utilized to develop the new package "Empirica 2000." We used exploratory factor analysis to identify the essential features in a large set of questionnaire data to see how…

  17. A microcomputer system for prescription, calculation, verification and recording of radiotherapy treatments

    International Nuclear Information System (INIS)

    Morrey, D.; Smith, C.W.; Belcher, R.A.; Harding, T.; Sutherland, W.H.

    1982-01-01

    The design of a microcomputer system for the reduction of mistakes in radiotherapy is described. The system covers prescription entry, prescription and treatment calculations, and verification and recording of the treatment set-up. A telecobalt unit was interfaced to the system and in the first 12 months 400 patients have been prescribed and 5000 treatment fields verified. The prescription is entered by the medical officer using an interactive program and this prescription provides the reference for verifying the treatment set-up. The program allows amendments to the prescription to be made easily during the treatment course. The treatment parameters verified are field size, wedge and treatment time. The system uses bar-codes for patient and field identification. A reduction in the number of mistakes has been achieved and future developments are discussed. (author)

  18. Design of automatic curtain controlled by wireless based on single chip 51 microcomputer

    Science.gov (United States)

    Han, Dafeng; Chen, Xiaoning

    2017-08-01

    In order to realize the wireless control of the domestic intelligent curtains, a set of wireless intelligent curtain control system based on 51 single chip microcomputer have been designed in this paper. The intelligent curtain can work in the manual mode, automatic mode and sleep mode and can be carried out by the button and mobile phone APP mode loop switch. Through the photosensitive resistance module and human pyroelectric infrared sensor to collect the indoor light value and the data whether there is the person in the room, and then after single chip processing, the motor drive module is controlled to realize the positive inversion of the asynchronous motor, the intelligent opening and closing of the curtain have been realized. The operation of the motor can be stopped under the action of the switch and the curtain opening and closing and timing switch can be controlled through the keys and mobile phone APP. The optical fiber intensity, working mode, curtain state and system time are displayed by LCD1602. The system has a high reliability and security under practical testing and with the popularity and development of smart home, the design has broad market prospects.

  19. MicroComputed Tomography: Methodology and Applications

    International Nuclear Information System (INIS)

    Stock, Stuart R.

    2009-01-01

    Due to the availability of commercial laboratory systems and the emergence of user facilities at synchrotron radiation sources, studies of microcomputed tomography or microCT have increased exponentially. MicroComputed Technology provides a complete introduction to the technology, describing how to use it effectively and understand its results. The first part of the book focuses on methodology, covering experimental methods, data analysis, and visualization approaches. The second part addresses various microCT applications, including porous solids, microstructural evolution, soft tissue studies, multimode studies, and indirect analyses. The author presents a sufficient amount of fundamental material so that those new to the field can develop a relative understanding of how to design their own microCT studies. One of the first full-length references dedicated to microCT, this book provides an accessible introduction to field, supplemented with application examples and color images.

  20. A microcomputer for a packet switched network

    International Nuclear Information System (INIS)

    Seller, P.; Bairstow, R.; Barlow, J.; Waters, M.

    1982-12-01

    The Bubble Chamber Research Group of the Rutherford and Appleton Laboratory has a large film analysis facility. This comprises 16 digitising tables used for the measurement of bubble chamber film. Each of these tables has an associated microcomputer. These microcomputers are linked by a star structured packet switched local area network (LAN) to a VAX 11/780. The LAN, and in particular a microcomputer of novel architecture designed to act as the central switch of the network, is described. (author)

  1. Hardware design of a microcomputer controlled diagnostic vacuum controller

    International Nuclear Information System (INIS)

    Marsala, R.J.

    1983-01-01

    The TFTR diagnostic vacuum controller (DVC) has been designed and built to control and monitor the pumps, valves and gauges which comprise a diagnostic vacuum system. The DVC is a microcomputer based self-contained controller with battery backup which may be controlled manually from front panel controls or remotely via CICADA. The DVC implements all pump and valve sequencing and provides protection against incorrect operation. There are presently two versions of the DVC operating on TFTR and a third version being used on the S-1 machine

  2. Physical characterization and performance evaluation of an x-ray micro-computed tomography system for dimensional metrology applications

    DEFF Research Database (Denmark)

    Hiller, Jochen; Maisl, Michael; Reindl, Leonard M

    2012-01-01

    This paper presents physical and metrological characterization measurements conducted for an industrial x-ray micro-computed tomography (CT) system. As is well known in CT metrology, many factors, e.g., in the scanning and reconstruction process, the image processing, and the 3D data evaluation...... components of a CT scanner, i.e. the x-ray tube and the flat-panel detector, are characterized. The contrast and noise transfer property of the scanner is obtained using image-processing methods based on linear systems theory. A long-term temperature measurement in the scanner cabinet has been carried out....... The dimensional measurement property has been quantified by using a calibrated ball-bar and uncertainty budgeting. Information about the performance of a CT scanner system in terms of contrast and noise transmission and sources of geometrical errors will help plan CT scans more efficiently. In particular...

  3. Portable microcomputer controlled radiation counter

    International Nuclear Information System (INIS)

    Mason, E.W.; Weber, J.M.

    1984-01-01

    A portable microcomputer controlled counter for use as a radiation counter is described. The counter uses digital processing of input pulses from a radiation detector. The number of counts received by the microcomputer per unit time is used to calculate a value for display using a calibration factor obtained during physical calibration of the instrument with a radiation source or with a pulse generator. The keyboard is used to enter calibration points. The number of calibration points which may be entered depends on the degree of accuracy desired by the user. The high voltage generator which drives the detector is triggered by pulses from the microcomputer in relation to the count rate. After processing the count, the resulting count rate or dose rate is displayed on the liquid crystal display. The counter is autoranging in which the decimal point is shifted as necessary by the microcomputer. The units displayed are determined by the user by means of a multiposition switch. Low battery and an overrange condition are displayed. An interface is provided via a connector to allow parallel transmission of data to peripheral devices. Low battery power consumption is featured. The counter is capable of providing more accurate readings than currently available counters

  4. Microcomputers in Education. Report No. 4798.

    Science.gov (United States)

    Feurzeig, W.; And Others

    A brief review of the history of computer-assisted instruction and discussion of the current and potential roles of microcomputers in education introduce this review of the capabilities of state-of-the-art microcomputers and currently available software for them, and some speculations about future trends and developments. A survey of current…

  5. Role of the Microcomputer-Based Laboratory Display in Supporting the Construction of New Understandings in Thermal Physics

    Science.gov (United States)

    Russell, David W.; Lucas, Keith B.; McRobbie, Campbell J.

    2004-01-01

    Teachers' failure to use the microcomputer-based laboratory (MBL) more widely may be a result of not recognizing its capacity to transform laboratory activities. This research aimed to increase understanding of how MBL activities designed to be consistent with a constructivist theory of learning support or constrain student construction of…

  6. Inexpensive remote video surveillance system with microcomputer and solar cells

    International Nuclear Information System (INIS)

    Guevara Betancourt, Edder

    2013-01-01

    A low-cost prototype is developed with a RPI plate for remote video surveillance. Additionally, the theoretical basis to provide energy independence have developed through solar cells and a battery bank. Some existing commercial monitoring systems are studied and analyzed, components such as: cameras, communication devices (WiFi and 3G), free software packages for video surveillance, control mechanisms and theory remote photovoltaic systems. A number of steps are developed to implement the module and install, configure and test each of the elements of hardware and software that make up the module, exploring the feasibility of providing intelligence to the system using the software chosen. Events that have been generated by motion detection have been simple, intuitive way to view, archive and extract. The implementation of the module by a microcomputer video surveillance and motion detection software (Zoneminder) has been an option for a lot of potential; as the platform for monitoring and recording data has provided all the tools to make a robust and secure surveillance. (author) [es

  7. Probabilistic safety analysis using microcomputer

    International Nuclear Information System (INIS)

    Futuro Filho, F.L.F.; Mendes, J.E.S.; Santos, M.J.P. dos

    1990-01-01

    The main steps of execution of a Probabilistic Safety Assessment (PSA) are presented in this report, as the study of the system description, construction of event trees and fault trees, and the calculation of overall unavailability of the systems. It is also presented the use of microcomputer in performing some tasks, highlightning the main characteristics of a software to perform adequately the job. A sample case of fault tree construction and calculation is presented, using the PSAPACK software, distributed by the IAEA (International Atomic Energy Agency) for training purpose. (author)

  8. Operation of commercially-based microcomputer technology in a space radiation environment

    Science.gov (United States)

    Yelverton, J. N.

    This paper focuses on detection and recovery techniques that should enable the reliable operation of commercially-based microprocessor technology in the harsh radiation environment of space and at high altitudes. This approach is especially significant in light of the current shift in emphasis (due to cost) from space hardened Class-S parts qualification to a more direct use of commercial parts. The method should offset some of the concern that the newer high density state-of-the-art RISC and CISC microprocessors can be used in future space applications. Also, commercial aviation, should benefit, since radiation induced transients are a new issue arising from the increased quantities of microcomputers used in aircraft avionics.

  9. Design and evaluation of a microcomputer-controlled remote pipetter system

    International Nuclear Information System (INIS)

    Goeringer, D.E.; Klatt, L.N.

    1981-01-01

    A remote pipetter has been designed and evaluated. The system is suitable for use in either a hot-cell or a glove-box environment and, therefore, is applicable in any situation where operating personnel must be separated from hazardous materials. The principle of operation for the pipetter is the displacement of liquid via a calibrated, screw-driven plunger. Variably sized aliquots of 1 to 1000 μL can be delivered. A steppng motor is used to move the plunger, and its position is verified with a linear variable differential transformer. The unit is controlled by a microcomputer. Besides the required operation sequences and error checking, a self-calibration check has been designed into the software. Measured accuracies and precisions of aliquot delivery are 0.4 and 0.2%, respectively

  10. Microcomputer control of automated TLD reader

    International Nuclear Information System (INIS)

    Bjarland, Bert.

    1979-10-01

    The interfacing electronics, the control algorithms and the developed programs of a 6800 microcomputer controlled automated TLD reader are described. The TL reading system is implemented with a photomultiplier tube and a charge-to-pulse converter. The gain of the TL reading system is controlled through the use of a temperature compensated LED reference light source. Automatic compensation of PM tube dark current is optional. The short term stability of TL readings is better than 3 %. (author)

  11. Microcomputer applications for NSSS data package review

    International Nuclear Information System (INIS)

    Eng, D.J.; Smith, F.M.

    1984-01-01

    Associated with each component of a Nuclear Steam Supply System are the necessary supporting documents which demonstrate compliance with applicable codes, specifications and design criteria. The documents are grouped into individual data packages, and may exceed 800 in number for a major installation. A complete review, initiated by a utility in response to federal code regulations (10 CFR 50), can involve a tremendous number of review transactions. A data management system to assist the reviewer in the tracking and resolution of discrepancy items is currently under development and use. The system uses microcomputer-based relational database management software and provides complete and flexible capabilities to process database components and attributes based on user specified criteria. The completed database is a ''portable'' system, and can be utilized on an as-needed basis after the review is completed. A discrepancy analysis is performed to identify relations between manufacturer and discrepancy occurrence, part type vs. discrepancy type, etc. These results may prove useful in subsequent reviews or application to existing QA procedures

  12. A spreadsheet-based microcomputer application for determining cost-effectiveness of commercial lighting retrofit opportunities

    International Nuclear Information System (INIS)

    Spain, T.K.

    1992-01-01

    Lighting accounts for 20-25% of electricity use in the United States. With estimates of 50-70% potential reductions being made by energy engineers, lighting is a promising area for cost-effective energy conservation projects in commercial buildings. With an extensive array of alternatives available to replace or modify existing lighting systems, simple but effective calculation tools are needed to help energy auditors evaluate lighting retrofits. This paper describes a spreadsheet-based microcomputer application for determining the cost-effectiveness of commercial lighting retrofits. Developed to support walk-through energy audits conducted by the Industrial Energy Advisory Service (IdEAS), the spreadsheet provides essential comparative data for evaluating the payback of alternatives. The impact of alternatives on environmental emissions is calculated to help communicate external costs and sell the project, if appropriate. The methodology and calculations are fully documented to allow the user to duplicate the spreadsheet and modify it as needed

  13. Microcomputer control of automated TL reader

    International Nuclear Information System (INIS)

    Bjarland, B.

    1980-01-01

    An automatic TL reader has been developed for use within a TLD based personal monitoring service. A 6800 based microcomputer is used for system control, operator communication, calibration and checking of reader operation, and for output of data. The dosimeter identity code is printed in human readable characters on the dosimeter card, and is read by using an optical character recognition unit. The code may include individual sensitivity correction coefficients for the TL chips on the card. The chips are heated with hot nitrogen gas and the thermoluminescence is recorded by a photomultiplier tube circuit, the gain and offset of which are continuously monitored and, when necessary, adjusted, to maintain calibration. The reader may operate in any of seven modes, i.e. reading modes for three types of dosimeters, semiautomatic modes for production of the three types of dosimeters, and a monitor mode. (Auth.)

  14. Development of γ dose rate monitor based on FPGA and single-chip microcomputer

    International Nuclear Information System (INIS)

    He Zhiguo; Ling Qiu; Guo Lanying; Yang Binhua

    2009-01-01

    A novelγdose rate monitor with multiple channels signal collection in which takes the FPGA as the core process chip and single-chip microcomputer as the data processor had been developed. This paper introduced the communication interface design between FPGA and MCU, and gave the data acquisition module and the function simulation chart designed by FPGA. In addition, the software and hardware design diagrams of MCU had been given in this paper. The maximum digitallization was carried on in the designing process. The experiments showed that the scheme for the system matched to the requests completely. (authors)

  15. Determination of patients contour for using in radiotherapy planning, by microcomputer

    International Nuclear Information System (INIS)

    Elbern, A.W.; Souto, S.L.L.

    1987-01-01

    This work describes a system for measuring the contour of patients, based on a mechanical device which, during the movement of its tip over the patient's contour, changes the resistence of three potenciometers while the device change its angles. The resistence variation, produces voltage changes, which are digitalized by an analog to digital converter in a microcomputer. The mathematical routines for processing the acquired data, and the obtained results, are discussed in this paper. (author) [pt

  16. Determination of patient's contour for use in radiotherapeutic planning by microcomputer

    International Nuclear Information System (INIS)

    Elbern, A.W.; Souto, S.L.L.

    1987-01-01

    A system for measuring the contour of patients based on a mechanical device, is described. During the movement of the device's tip, over the patient's contour, changes in the resistence of three potenciometers are reported, and the device changes its angles. Voltage changes produced by resistence variation, are digitalized by an analog to digital converter in a micro-computer. The mathematical routines for processing the acquired data, and the obtained results are discussed. (M.A.C.) [pt

  17. Design and manufacture of TL analyser by using the microcomputer

    International Nuclear Information System (INIS)

    Doh, Sih Hong; Woo, Chong Ho

    1986-01-01

    This paper describes the design of the thermoluminescence analyser using microcomputer. TL analyser is designed to perform the three step heat treatment, such as pre-read heating, readout procedure and post-heating (or pre-irradiation ) anneal. We used a 12-bit A/D converter to get the precise measurement and the phase control method to control the heating temperature. Since the used Apple II microcomputer is cheap and popular, it is possible to design the economical system. Experimental results showed the successful operation with flexibility. The error of temperature control was less than ± 0.2% of the expected value. (Author)

  18. An on-line pressurizer surveillance system design to prevent small-break loss-of-coolant accidents through power-operated relief valves using a microcomputer

    International Nuclear Information System (INIS)

    Lee, J.H.; Chang, S.H.

    1987-01-01

    A small-break loss-of-coolant accident (LOCA) caused by a stuck-open power-operated relief valve is one of the important contributors to nuclear power plant risk. A pressurizer surveillance system was designed to use a microcomputer to prevent the malfunction of the system; the effect of this improvement has been assessed through probabilistic risk assessment. The microcomputer diagnoses the malfunction of the system by a process-checking method and automatically performs the backup action related to each malfunction. This improvement means that we can correctly diagnose ''spurious opening,'' ''failure to reclose,'' and ''small-break LOCA,'' which are difficult for operators to diagnose quickly and correctly, and by taking automatic backup action one can reduce the probability of human error

  19. Microcomputer Database Management Systems that Interface with Online Public Access Catalogs.

    Science.gov (United States)

    Rice, James

    1988-01-01

    Describes a study that assessed the availability and use of microcomputer database management interfaces to online public access catalogs. The software capabilities needed to effect such an interface are identified, and available software packages are evaluated by these criteria. A directory of software vendors is provided. (4 notes with…

  20. Volumetric quantification of bone-implant contact using micro-computed tomography analysis based on region-based segmentation.

    Science.gov (United States)

    Kang, Sung-Won; Lee, Woo-Jin; Choi, Soon-Chul; Lee, Sam-Sun; Heo, Min-Suk; Huh, Kyung-Hoe; Kim, Tae-Il; Yi, Won-Jin

    2015-03-01

    We have developed a new method of segmenting the areas of absorbable implants and bone using region-based segmentation of micro-computed tomography (micro-CT) images, which allowed us to quantify volumetric bone-implant contact (VBIC) and volumetric absorption (VA). The simple threshold technique generally used in micro-CT analysis cannot be used to segment the areas of absorbable implants and bone. Instead, a region-based segmentation method, a region-labeling method, and subsequent morphological operations were successively applied to micro-CT images. The three-dimensional VBIC and VA of the absorbable implant were then calculated over the entire volume of the implant. Two-dimensional (2D) bone-implant contact (BIC) and bone area (BA) were also measured based on the conventional histomorphometric method. VA and VBIC increased significantly with as the healing period increased (pimplants using micro-CT analysis using a region-based segmentation method.

  1. Management of quality assurance in diagnostic radiology by microcomputer

    International Nuclear Information System (INIS)

    Evans, S.H.

    1985-01-01

    Software has been written for the calculation, interpretation and presentation of quality control measurements of X-ray machines. The programs run on a Z80 based microcomputer system comprising a Comart Communicator CP500 interfaced to a Volker Craig 4404 visual display unit (VDU) and an EpsonMX80F/T printer. The software has been written in the dbaseII database language (Ashton Tate 1975) and it runs under the CP/M operating system. The programs guide the user through each routine required and can be operated without knowledge of computers. The programs calculate the results from the raw data obtained from the test equipment and these results are then stored and analysed. (U.K.)

  2. Learning motion concepts using real-time microcomputer-based laboratory tools

    Science.gov (United States)

    Thornton, Ronald K.; Sokoloff, David R.

    1990-09-01

    Microcomputer-based laboratory (MBL) tools have been developed which interface to Apple II and Macintosh computers. Students use these tools to collect physical data that are graphed in real time and then can be manipulated and analyzed. The MBL tools have made possible discovery-based laboratory curricula that embody results from educational research. These curricula allow students to take an active role in their learning and encourage them to construct physical knowledge from observation of the physical world. The curricula encourage collaborative learning by taking advantage of the fact that MBL tools present data in an immediately understandable graphical form. This article describes one of the tools—the motion detector (hardware and software)—and the kinematics curriculum. The effectiveness of this curriculum compared to traditional college and university methods for helping students learn basic kinematics concepts has been evaluated by pre- and post-testing and by observation. There is strong evidence for significantly improved learning and retention by students who used the MBL materials, compared to those taught in lecture.

  3. Software of microcomputer ELEKTRONIKA-60 installed in the control system of the measuring projector PUOS-4

    International Nuclear Information System (INIS)

    Dikij, V.M.; Nekipelova, G.D.; Shakhbazyan, V.V.; Yurpalov, V.D.

    1990-01-01

    The tasks, structure and aspects of realization of servodrivers of the PUOS-4 measuring projector (measuring carriage, tape transport) on the installed ELEKTRONIKA-60 microcomputer operating in the multi-machine system of film information preprocessing, are considered. Realizability of drivers is estimated under rigid operation conditions using the RTM60 real time monitor. The problem of the projector testing is also considered. 11 refs.; 5 figs.; 1 tab

  4. Application of Minicomputers and Microcomputers to Information Handling.

    Science.gov (United States)

    Griffiths, Jose-Marie

    This study assesses the application of both minicomputers and microcomputers to information-handling procedures and makes recommendations for automating such procedures, particularly in developing nations. The report is based on a survey of existing uses of small computing equipment in libraries, archives, and information centers which was…

  5. Tevatron extraction microcomputer

    International Nuclear Information System (INIS)

    Chapman, L.; Finley, D.A.; Harrison, M.; Merz, W.

    1985-06-01

    Extraction in the Fermilab Tevatron is controlled by a multi-processor Multibus microcomputer system called QXR (Quad eXtraction Regulator). QXR monitors several analog beam signals and controls three sets of power supplies: the ''bucker'' and ''pulse'' magnets at a rate of 5760 Hz, and the ''QXR'' magnets at 720 Hz. QXR supports multiple slow spills (up to a total of 35 seconds) with multiple fast pulses intermixed. It linearizes the slow spill and bucks out the high frequency components. Fast extraction is done by outputting a variable pulse waveform. Closed loop learning techniques are used to improve performance from cycle to cycle for both slow and fast extraction. The system is connected to the Tevatron clock system so that it can track the machine cycle. QXR is also connected to the rest of the Fermilab control system, ACNET. Through ACNET, human operators and central computers can monitor and control extraction through communications with QXR. The controls hardware and software both employ some standard and some specialized components. This paper gives an overview of QXR as a control system; another paper summarizes performance

  6. Evaluation of autoradiograms using a microcomputer

    International Nuclear Information System (INIS)

    Birkholz, W.; Steinert, M.

    1983-01-01

    An equipment AURAS for evalutaion of autoradiograms has been developed. It consists of a digital photometer and the densitron system (television scanner) for digitalisation of pictures and a microprocessor for picture processing and storing of datas. The digital photometer permits a precise but time consuming scanning. The densitron system works quickly with little density classes and pseudocolouring of pictures. For the evaluation of autoradiograms with the microcomputer a programsystem MARAUS was written. It works in a dialogeous regime. The possibilities of using the equipment for evaluation of autoradiograms are demonstrated. (author)

  7. Reactor physics using a microcomputer

    International Nuclear Information System (INIS)

    Murray, R.L.

    1983-01-01

    The object of the work reported is to develop educational computer modules for all aspects of reactor physics. The modules consist of a description of the theory, mathematical method, computer program listing, sample calculations, and problems for the student, along with a card deck. Modules were first written in FORTRAN for an IBM 360/75, then later in BASIC for microcomputers. Problems include: limitation of equipment, choice of format for the program, the variety of dialects of BASIC used in the different microcomputer and peripherals brands, and knowing when to quit in the process of developing a program

  8. Microcomputers as on-line catalogs in special libraries.

    Science.gov (United States)

    Faust, J B

    1986-01-01

    This article discusses the rationale for the conversion of a card catalog to an on-line system in a special library owning approximately 4000 titles. Equipment, software, and procedures are described. Pros and cons of the use of a microcomputer for such a project, as well as costs and personnel needs, are outlined.

  9. PC-based Multiple Information System Interface (PC/MISI) design plan

    Science.gov (United States)

    Dominick, Wayne D. (Editor); Hall, Philip P.

    1985-01-01

    The general design plan for the implementation of a common user interface to multiple remote information systems within a microcomputer-based environment is presented. The intent is to provide a framework for the development of detailed specifications which will be used as guidelines for the actual development of the system.

  10. Micro-computer based communication system

    International Nuclear Information System (INIS)

    Meyers, M.; Hinton, C.; Pauly, C.; Tau, S.; Rathmell, R.

    1981-01-01

    The CNEA 20UD tandem accelerator manufactured by National Electrostatics Corp. is predominately controlled through a hard wired console. In the past, accelerators have used mechanical control rods to control parameters inside the high voltage terminals and dead sections. The 20UD column, has relatively complex equipment within the terminal and dead sections. Because of its complexity and the length of the column (approximately 48 ft. from ground to terminal) it was concluded that a digital communication link would be required to provide the smooth, high resolution control needed for the ion-optic components and to provide a reliable system to monitor the large number of parameters. To further ensure reliability, some basic components such as foil strippers and the terminal matching quadrupole have back-up control via control rods to allow limited operation in the event of a failure of the digital system

  11. The artificial satellite observation chronograph controlled by single chip microcomputer.

    Science.gov (United States)

    Pan, Guangrong; Tan, Jufan; Ding, Yuanjun

    1991-06-01

    The instrument specifications, hardware structure, software design, and other characteristics of the chronograph mounting on a theodolite used for artificial satellite observation are presented. The instrument is a real time control system with a single chip microcomputer.

  12. Microcomputers and Informatics Education at the University Level.

    Science.gov (United States)

    Boyanov, Todor

    1984-01-01

    Because of the widespread use of microcomputers in Bulgaria, informatics education for all college students is considered both possible and necessary. Uses of microcomputers in various disciplines are described, including those in mathematics/mechanics, the experimental sciences, and humanities. Brief comments on computer-assisted-learning and…

  13. Application of microcomputer to X-ray radiometric ore separation

    International Nuclear Information System (INIS)

    Neverov, A.D.; Aleksandrov, P.S.; Kotler, N.I.

    1988-01-01

    The practical use of microcomputers as universal means for converting information for solving applied problems of X-ray radiometric ore separation method is considered. Laboratory tests of two metals - tungsten and tin manifested high efficiency of the developed system. X-ray radiometric separator software is developed

  14. An On-line Microcomputer Course for Pre-service Teachers.

    Science.gov (United States)

    Abkemeier, Mary K.

    This paper describes "Microcomputer Applications for Educators," a course at Fontbonne College for pre-service teachers which introduces the educational applications of the computer and related technologies. The course introduces students to the Macintosh computer, its operating system, Claris Works 4.0, and various other educational and…

  15. SUPER CAVIAR: Memory mapping the general-purpose microcomputer

    International Nuclear Information System (INIS)

    Cittolin, S.; Taylor, B.G.

    1981-01-01

    Over the past 3 years, CAVIAR (CAMAC Video Autonomous Read-out) microcomputers have been applied in growing numbers at CERN and related institutes. As typical user programs expanded in size, and the incorporated firmware libraries were enlarged also, the microprocessor addressing limit of 64 Kbytes became a serious constraint. An enhanced microcomputer, SUPER CAVIAR, has now been created by the incorporation of memory mapping to expand the physical address space to 344 Kbytes. The new facility provides independent firmware and RAM maps, dynamic allocation of common RAM, automatic inter-page transfer modes, and a RAM/EPROM overlay. A memory-based file system has been implemented, and control and data can be interchanged between separate programs in different RAM maps. 84 Kbytes of EPROM are incorporated on the mapper card itself, as well as an ADLC serial data link. In addition to providing more space for consolidated user programs and data, SUPER CAVIAR has allowed the introduction of several improvements to the BAMBI interpreter and extensions to the CAVIAR libraries. A context editor and enhanced debug monitor have been added, as well as new data types and extended array-handling and graphics routines, including isoline plotting, line-fitting and FFT operations. A SUPER CAVIAR converter has been developed which allows a standard CAVIAR to be upgraded to incorporate the new facilities without loss of the existing investment. (orig.)

  16. The microcomputer-based expert system in CAD-PV

    International Nuclear Information System (INIS)

    Wang, Y.; Qin, S.

    1987-01-01

    As a branch of artificial intelligence, expert system has been revealed day after day in more and more engineering scopes since the successful applications of MYCIN in diagnosis and DENDRAL in the molecular structure of organic compounds etc.. But in the design scope of pressure vessel, as we know, only a few papers have so far been published with respect to the expert system. The necessity and feasibility of accompanying CAD-PV with expert system attracted more scholars to engage in. Although many countries, including China, have regularized the design standards or codes for pressure vessel, but of which no one can solve all of the problems concerning the various practical occasions and experiences. In general, the more domain knowledges a design engineer possesses of, the better decision will be made by him. By virtue of the expert system any less experienced engineer could make the optimum decision in design as well as a skilled senior engineer in addition to the application of design code. It is the due significance for developing high level expert system as an intelligence assistant in the plan option of CAD-PV. In this paper we attempt to introduce a specified software JACKPV used in the design procedure of jacketed pressure vessel as an intelligence front in CAD-PV. JACKPV consists of the function of expert system based on the personal computer IBM-PC/XT with the language PASCAL in its program. It was proved that an ordinary CAD software could be effectively improved while equipped with expert system. (orig.)

  17. Final report : evaluation of microcomputer applications in transportation engineering.

    Science.gov (United States)

    1984-01-01

    This study investigated areas where microcomputers can aid in the effectiveness of transportation engineering at state and local levels. A survey of the microcomputer needs of transportation professionals in state and local agencies in Virginia was c...

  18. Programme in Basic-Applesoft language for microcomputer to analyse pulse spectra from a high-resolution gamma ray system

    International Nuclear Information System (INIS)

    Nascimento Filho, V.F. do; Marques, D.A.; Pessenda, L.C.R.; Barros Ferraz, E.S. de; Nadai, E.A. de; Sao Paulo Univ., Piracicaba

    1988-01-01

    A programme in BASIC-Applesoft language has been developed for low cost microcomputer to analyze spectra from a high-resolution gamma-ray system (high-purity germanium and 4096 channels analyzer). Data is received by the microcomputer directly from analyzer (4 min) or keyboard and shown on video (4 min) or printed (9,7 min). Graphics of parts of the spectrum can be either shown on video (a cursor is used to identify peaks) or printed. The peak search, centroid, energy, net photopeak area, standard deviation and relative standard deviation are included in the programme (5 min), besides filing of data in flexible disk (1,3 min). The programme was used on a 12 h real-time detection in Marinelli beaker of 1265 g sandy soil sample (Ref-Yellow Latosol, 0-3 cm layer). Thirty-one peaks from U-238 and Th-232 daughters were analyzed (rsd less than 20%), besides natural K-40 and artificial Cs-137, from fallout. (author) [pt

  19. Tevatron extraction microcomputer

    International Nuclear Information System (INIS)

    Chapman, L.; Finley, D.A.; Harrison, M.; Merz, W.; Batavia, IL)

    1985-01-01

    Extraction in the Fermilab Tevatron is controlled by a multi-processor Multibus microcomputer system called QXR (Quad eXtraction Regulator). QXR monitors several analog beam signals and controls three sets of power supplies: the ''bucker'' and ''pulse'' magnets at a rate of 5760 Hz, and the ''QXR'' magnets at 720 Hz. QXR supports multiple slow spills (up to a total of 35 seconds) with multiple fast pulses intermixed. It linearizes the slow spill and bucks out the high frequency components. Fast extraction is done by outputting a variable pulse waveform. Closed loop learning techniques are used to improve performance from cycle to cycle for both slow and fast extraction. The system is connected to the Tevatron clock system so that it can track the machine cycle. QXR is also connected to the rest of the Fermilab control system, ACNET. Through ACNET, human operators and central computers can monitor and control extraction through communications with QXR. The controls hardware and software both employ some standard and some specialized components. This paper gives an overview of QXR as a control system; another paper (1) summarizes performance

  20. Dumping Low and High Resolution Graphics on the Apple IIe Microcomputer System.

    Science.gov (United States)

    Fletcher, Richard K., Jr.; Ruckman, Frank, Jr.

    This paper discusses and outlines procedures for obtaining a hard copy of the graphic output of a microcomputer or "dumping a graphic" using the Apple Dot Matrix Printer with the Apple Parallel Interface Card, and the Imagewriter Printer with the Apple Super Serial Interface Card. Hardware configurations and instructions for high…

  1. Economical motor protection using microcomputer technology

    Energy Technology Data Exchange (ETDEWEB)

    Woodruff, N.

    1983-09-01

    A trend to design new motors closer to their design limits and the high cost of plant shutdown has increased the need for better protection of smaller three phase motors. A single chip microcomputer relay can be applied to replace thermal overloads which are of limited effectiveness on low and medium voltage machines with comprehensive, economical motor protection. The requirement for different protection features and how they are achieved is presented. All the protection features discussed are commercially available in a compact unit that uses a single chip microcomputer.

  2. Volumetric quantification of bone-implant contact using micro-computed tomography analysis based on region-based segmentation

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Sung Won; Lee, Woo Jin; Choi, Soon Chul; Lee, Sam Sun; Heo, Min Suk; Huh, Kyung Hoe; Kim, Tae Il; Yi, Won Ji [Dental Research Institute, School of Dentistry, Seoul National University, Seoul (Korea, Republic of)

    2015-03-15

    We have developed a new method of segmenting the areas of absorbable implants and bone using region-based segmentation of micro-computed tomography (micro-CT) images, which allowed us to quantify volumetric bone-implant contact (VBIC) and volumetric absorption (VA). The simple threshold technique generally used in micro-CT analysis cannot be used to segment the areas of absorbable implants and bone. Instead, a region-based segmentation method, a region-labeling method, and subsequent morphological operations were successively applied to micro-CT images. The three-dimensional VBIC and VA of the absorbable implant were then calculated over the entire volume of the implant. Two-dimensional (2D) bone-implant contact (BIC) and bone area (BA) were also measured based on the conventional histomorphometric method. VA and VBIC increased significantly with as the healing period increased (p<0.05). VBIC values were significantly correlated with VA values (p<0.05) and with 2D BIC values (p<0.05). It is possible to quantify VBIC and VA for absorbable implants using micro-CT analysis using a region-based segmentation method.

  3. Volumetric quantification of bone-implant contact using micro-computed tomography analysis based on region-based segmentation

    International Nuclear Information System (INIS)

    Kang, Sung Won; Lee, Woo Jin; Choi, Soon Chul; Lee, Sam Sun; Heo, Min Suk; Huh, Kyung Hoe; Kim, Tae Il; Yi, Won Ji

    2015-01-01

    We have developed a new method of segmenting the areas of absorbable implants and bone using region-based segmentation of micro-computed tomography (micro-CT) images, which allowed us to quantify volumetric bone-implant contact (VBIC) and volumetric absorption (VA). The simple threshold technique generally used in micro-CT analysis cannot be used to segment the areas of absorbable implants and bone. Instead, a region-based segmentation method, a region-labeling method, and subsequent morphological operations were successively applied to micro-CT images. The three-dimensional VBIC and VA of the absorbable implant were then calculated over the entire volume of the implant. Two-dimensional (2D) bone-implant contact (BIC) and bone area (BA) were also measured based on the conventional histomorphometric method. VA and VBIC increased significantly with as the healing period increased (p<0.05). VBIC values were significantly correlated with VA values (p<0.05) and with 2D BIC values (p<0.05). It is possible to quantify VBIC and VA for absorbable implants using micro-CT analysis using a region-based segmentation method.

  4. Interpretive Reporting of Protein Electrophoresis Data by Microcomputer

    Science.gov (United States)

    Talamo, Thomas S.; Losos, Frank J.; Kessler, G. Frederick

    1982-01-01

    A microcomputer based system for interpretive reporting of protein electrophoretic data has been developed. Data for serum, urine and cerebrospinal fluid protein electrophoreses as well as immunoelectrophoresis can be entered. Patient demographic information is entered through the keyboard followed by manual entry of total and fractionated protein levels obtained after densitometer scanning of the electrophoretic strip. The patterns are then coded, interpreted, and final reports generated. In most cases interpretation time is less than one second. Misinterpretation by computer is uncommon and can be corrected by edit functions within the system. These discrepancies between computer and pathologist interpretation are automatically stored in a data file for later review and possible program modification. Any or all previous tests on a patient may be reviewed with graphic display of the electrophoretic pattern. The system has been in use for several months and is presently well accepted by both laboratory and clinical staff. It also allows rapid storage, retrieval and analysis of protein electrophoretic datab.

  5. Therapeutic hypertension system based on a microbreathing pressure sensor system

    Directory of Open Access Journals (Sweden)

    Diao Z

    2011-05-01

    Full Text Available Ziji Diao1, Hongying Liu1, Lan Zhu1, Xiaoqiang Gao1, Suwen Zhao1, Xitian Pi1,2, Xiaolin Zheng1,21Key Laboratory of Biorheological Science and Technology, Chongqing University, Ministry of Education, Chongqing; 2Key Laboratories for National Defense Science and Technology of Innovative Micronano Devices and System Technology, Chongqing, People’s Republic of ChinaBackground and methods: A novel therapeutic system for the treatment of hypertension was developed on the basis of a slow-breath training mechanism, using a microbreathing pressure sensor device for the detection of human respiratory signals attached to the abdomen. The system utilizes a single-chip AT89C51 microcomputer as a core processor, programmed by Microsoft Visual C++6.0 to communicate with a PC via a full-speed PDIUSBD12 interface chip. The programming is based on a slow-breath guided algorithm in which the respiratory signal serves as a physiological feedback parameter. Inhalation and exhalation by the subject is guided by music signals.Results and conclusion: Our study indicates that this microbreathing sensor system may assist in slow-breath training and may help to decrease blood pressure.Keywords: hypertension, microbreathing sensor, single-chip microcomputer, slow-pace breathing

  6. A novel, microcomputer-based process control scheme for radiochemistry autosynthesizers

    International Nuclear Information System (INIS)

    Feliu, A.L.

    1989-01-01

    With the continuing development of positron emission tomography, increasing emphasis is being given to the design of reliable autosynthesizers to supply routinely-used radiopharmaceuticals. In order to reduce the time required to automate the synthesis of new radiotracers, a software scheme is proposed which includes: a generic control program supporting a standard set of components, end-user customization of the video display, mouse-driven remote control of individual components (components are presented on screen as icons), and a batch language for completely automating synthetic operations. This strategy is illustrated in a chemist-friendly microcomputer softward package running under MS-DOS which exploits the features and full flexibility of the CTI/Siemens Chemical Process Control Unit. To facilitate system expansion, the program, written in Microsoft QuickBASIC, contains generic executive-level code with calls to component-specific GOSUBs, and is designed to accommodate operation or hardware modifications in response to improvements in synthetic art without a rewrite. Two user-generated configuration files detail synthesis-specific parameters, providing a customized interface

  7. The Design Of The Ultrasonic Nondestructive Testing System Based On The EMAT

    Directory of Open Access Journals (Sweden)

    Cheng Huan Xin

    2016-01-01

    Full Text Available This paper introduces a kind of based on the electromagnetic acoustic transducer (EMAT metal pipeline detection system, fusion of two dimensional orientation, shape unique technological innovation, implementation of various metal pipe wall corrosion situation of rapid, accurate, fully automated non-destructive testing.In the aspect of hardware design, single-chip microcomputer control was achieved by C language programming the launch of the pulse signal. Pulse signal was sent to launch circuit, ultrasonic signal. Design of preamplifier, controllable gain amplifier two-stage amplifier circuit for receiving signal is amplified. Including data acquisition circuit detection circuit and A/D conversion circuit, single chip microcomputer and the LabVIEW platform via A serial port communication agreement. In the aspect of software design, the design of the EMAT pipe nondestructive testing system based on LabVIEW human-computer interaction interface.

  8. The microcomputer: A tool for personal language learning

    Directory of Open Access Journals (Sweden)

    David H. Wyatt

    2013-02-01

    Full Text Available Computer-assisted methods of teaching and learning languages have been surrounded by controversy and debate for over a decade. In 1979, however, microcomputers began to appear in a form suitable for educational applications, offering for the first time an alternative to both the cost and the approach of large computer systems. The impact of the microcomputer has been limited by a number of factors, and microcomputerassisted learning is still in a relative state of infancy. The main implications for language teaching and learning are only now beginning to be understood, just as the limiting factors are starting to disappear. This paper will assess the present situation and outline some likely future developments in the use of microcomputers in language learning. Rekenaargesteunde metodes by die onderrig en aanleer van tale is reeds meer as 'n dekade lank omgewe deur meningsverskil. In 1979 egter het mikrorekenaars hulle verskyning begin maak in 'n toepaslike vorm vir opvoedkundige doeleindes. Vir die eerste keer was daar 'n alternatief vir die koste verbonde aan en die benaderingswyse van groot rekenaarstelsels. Die trefkrag van die mikrorekenaar is deur 'n aantal faktore gekortwiek en rekenaargesteunde onderrig is steeds in sy kinderskoene. Die belangrikste implikasies vir die aanleer en onderrig van tale begin nou eers deurdring soos die beperkende faktore begin verdwyn. Hierdie artikel takseer die huidige situasie en omlyn moontlike toekomstige ontwikkelings vir die gebruik van mikrorekenaars by taalaanleer.

  9. Use of a microprocessor in the CAMAC standard. The dedicated microcomputer: JCAM-10

    International Nuclear Information System (INIS)

    Gallice, Pierre.

    1978-01-01

    The general purpose minicomputers and dedicated crate controllers currently used in small CAMAC systems are now being superseded by autonomous crate controllers with built-in microprocessor such as the JCAM-10, which is in fact a CAMAC dedicated microcomputer. This controller has been designed around the INTEL-8080 microprocessor and employs a semiconductor memory. The very much reduced price and smaller packaging of this module, and the relatively large potential market of CAMAC systems justify the tremendous efforts required for the study of its complete system as well in hardware than in software. After a short description of the CAMAC standard this paper will describe the principle of the microcomputer JCAM-10, and its complementary system: hardware (peripheral modules) and software (TTY command processor, Input Output, Control system, interrupt system, text editor, local macro-assembler, LP and BASICAM local compilers). As application examples, an autonomous counting system and a distributed intelligence system will be described [fr

  10. Microcomputer package for statistical analysis of microbial populations.

    Science.gov (United States)

    Lacroix, J M; Lavoie, M C

    1987-11-01

    We have developed a Pascal system to compare microbial populations from different ecological sites using microcomputers. The values calculated are: the coverage value and its standard error, the minimum similarity and the geometric similarity between two biological samples, and the Lambda test consisting of calculating the ratio of the mean similarity between two subsets by the mean similarity within subsets. This system is written for Apple II, IBM or compatible computers, but it can work for any computer which can use CP/M, if the programs are recompiled for such a system.

  11. X-ray quality increasing system controlled by single-chip microcomputer in single phase fluoroscopy unit

    International Nuclear Information System (INIS)

    Wang Qiaolin; Gu Hongmei

    2004-01-01

    Objective: To decrease the amount of radiation that doctor and patient receives by increasing X-ray quality. Methods: Using Single-chip Microcomputer technology, test and modulate AC(Alternating Current) from high voltage generator by IGBT. X-ray tube generates X-rays only at high energy area. Thus the amount of radiation decreases. Results: The tube current decreases remarkably and the amount of radiation that doctor and patient receives decreases effectively. Conclusion: the system can effectively decrease the amount of radiation and is widely applicable to the upgrade of all kinds of single phase X-ray units. (authors)

  12. Application of single-chip microcomputer in radiation detection

    International Nuclear Information System (INIS)

    Zhang Songshou

    1993-01-01

    The single-chip microcomputer has some advantages in many aspects for example the strong function, the small volume, the low-power, firmed and reliable. It is used widely in the control of industry, instrument, communication and machine, etc.. The paper introduces that the single-chip microcomputer is used in radiation detection, mostly including the use of control, linear, compensation, calculation, prefabricated change, improving precision and training

  13. Data acquisition system and performance based on Apple II for using in experimental physics - Applications to spectrophotometer

    International Nuclear Information System (INIS)

    Costa, L.F.; Castro, J.C.

    1987-01-01

    A microcomputer based system oriented to experimental physics is described. The system was developed to achieve versatility, low cost, reliability and easy utilization. An application to this system to a dispersive spectrophotometer is also included. (author) [pt

  14. Direct microcomputer controlled determination of zinc in human serum by flow injection atomic absorption spectrometry

    DEFF Research Database (Denmark)

    Simonsen, Kirsten Wiese; Nielsen, Bent; Jensen, Arne

    1986-01-01

    A procedure is described for the direct determination of zinc in human serum by fully automated, microcomputer controlled flow injection atomic absorption spectrometry (Fl-AAS). The Fl system is pumpless, using the negative pressure created by the nebuliser. It only consists of a three-way valve......, programmable from the microcomputer, to control the sample volume. No pre-treatment of the samples is necessary. The limit of detection is 0.14 mg l–1, and only small amounts of serum (

  15. The single chip microcomputer technique in an intelligent nuclear instrument

    International Nuclear Information System (INIS)

    Wang Tieliu; Sun Punan; Wang Ying

    1995-01-01

    The authors present that how to acquire and process the output signals from the nuclear detector adopting single chip microcomputer technique, including working principles and the designing method of the computer's software and hardware in the single chip microcomputer instrument

  16. Single-chip microcomputer application in nuclear radiation monitoring instruments

    International Nuclear Information System (INIS)

    Zhang Songshou

    1994-01-01

    The single-chip microcomputer has advantage in many respects i.e. multiple function, small size, low-power consumption,reliability etc. It is widely used now in industry, instrumentation, communication and machinery. The author introduced usage of single-chip microcomputer in nuclear radiation monitoring instruments for control, linear compensation, calculation, changeable parameter presetting and military training

  17. Microcomputer Decisions for the 1990s [and] Apple's Macintosh: A Viable Choice.

    Science.gov (United States)

    Grosch, Audrey N.

    1989-01-01

    Discussion of the factors that should be considered when purchasing or upgrading a microcomputer focuses on the MS-DOS and OS/2 operating systems. Macintosh purchasing decisions are discussed in a sidebar. A glossary is provided. (CLB)

  18. Gamma spectrometric system based on the personal computer Pravetz-83

    International Nuclear Information System (INIS)

    Yanakiev, K; Grigorov, T.; Vuchkov, M.

    1985-01-01

    A gamma spectrometric system based on a personal microcomputer Pravets-85 is described. The analog modules are NIM standard. ADC data are stored in the memory of the computer via a DMA channel and a real-time data processing is possible. The results from a series of tests indicate that the performance of the system is comparable with that of comercially avalable computerized spectrometers Ortec and Canberra

  19. Microcomputer Typewriting in Business Education.

    Science.gov (United States)

    Schmidt, B. June; Stewart, Jeffrey R.

    1983-01-01

    Describes a research project on the role of the instructor in managing microcomputer typewriting instruction. The teachers selected software, familiarized students with the equipment, provided support, monitored progress, helped students establish goals, and provided instructional activities. (JOW)

  20. Microprocessor based data acquisition system for Moessbauer spectrometer

    International Nuclear Information System (INIS)

    Patwardhan, P.K.; Indurkar, V.S.

    1981-01-01

    A data acquisition system, for Moessbauer spectrometer and other probability distribution spectrum is described. This utilizes the advantages of incorporating a microcomputer for providing a flexible analytical capability and speed of hard wired MCS unit updating channel contents in DMA. Holbourn, Player and Woodhams have recently described a microprocessor controlled Moessbauer spectrometer where microprocessor performs the task of updating channel contents, requiring about 60 micro seconds in interrupt mode. This imposes restrictions on increasing the channel number and on increasing the velocity scan frequency in order to cover higher velocity ranges. The system described in this article performs data acquisition in faster direct memory access. It is a two module system, (1) MCS module (2) Microcomputer module, arranged around a common address, data and control buses. The microcomputer module has an access to the system data during flyback periods and can be programmed for the task of monitor on progess of experiment and as a manipulator of various control operations needed during experiment. The system firmware includes: (1) MONITOR (2) BLOCK-TRANSFER (3) DATA-SMOOTHING (4) DECIMAL-CONVERTER (5) MATH. The scope of this firmware is briefly described. (author)

  1. Micro-Computers in Biology Inquiry.

    Science.gov (United States)

    Barnato, Carolyn; Barrett, Kathy

    1981-01-01

    Describes the modification of computer programs (BISON and POLLUT) to accommodate species and areas indigenous to the Pacific Coast area. Suggests that these programs, suitable for PET microcomputers, may foster a long-term, ongoing, inquiry-directed approach in biology. (DS)

  2. Microcomputer-based tests for repeated-measures: Metric properties and predictive validities

    Science.gov (United States)

    Kennedy, Robert S.; Baltzley, Dennis R.; Dunlap, William P.; Wilkes, Robert L.; Kuntz, Lois-Ann

    1989-01-01

    A menu of psychomotor and mental acuity tests were refined. Field applications of such a battery are, for example, a study of the effects of toxic agents or exotic environments on performance readiness, or the determination of fitness for duty. The key requirement of these tasks is that they be suitable for repeated-measures applications, and so questions of stability and reliability are a continuing, central focus of this work. After the initial (practice) session, seven replications of 14 microcomputer-based performance tests (32 measures) were completed by 37 subjects. Each test in the battery had previously been shown to stabilize in less than five 90-second administrations and to possess retest reliabilities greater than r = 0.707 for three minutes of testing. However, all the tests had never been administered together as a battery and they had never been self-administered. In order to provide predictive validity for intelligence measurement, the Wechsler Adult Intelligence Scale-Revised and the Wonderlic Personnel Test were obtained on the same subjects.

  3. Reinforcement and Drill by Microcomputer.

    Science.gov (United States)

    Balajthy, Ernest

    1984-01-01

    Points out why drill work has a role in the language arts classroom, explores the possibilities of using a microcomputer to give children drill work, and discusses the characteristics of a good software program, along with faults found in many software programs. (FL)

  4. Microcomputers in the Introductory Laboratory.

    Science.gov (United States)

    Bare, John K.

    1982-01-01

    A microcomputer was used successfully to replicate Sternberg's 1966 study of retrieval from short-term memory and Sperling's 1960 study on sensory or iconic memory. Computers with a capacity for measuring reaction time are useful in the laboratory for introductory psychology courses. (SR)

  5. Enlist micros: Training science teachers to use microcomputers

    Science.gov (United States)

    Baird, William E.; Ellis, James D.; Kuerbis, Paul J.

    A National Science Foundation grant to the Biological Sciences Curriculum Study (BSCS) at The Colorado College supported the design and production of training materials to encourage literacy of science teachers in the use of microcomputers. ENLIST Micros is based on results of a national needs assessment that identified 22 compentencies needed by K-12 science teachers to use microcomputers for instruction. A writing team developed the 16-hour training program in the summer of 1985, and field-test coordinators tested it with 18 preservice or in-service groups during the 1985-86 academic year at 15 sites within the United States. The training materials consist of video programs, interactive computer disks for the Apple II series microcomputer, a training manual for participants, and a guide for the group leader. The experimental materials address major areas of educational computing: awareness, applications, implementation, evaluation, and resources. Each chapter contains activities developed for this program, such as viewing video segments of science teachers who are using computers effectively and running commercial science and training courseware. Role playing and small-group interaction help the teachers overcome their reluctance to use computers and plan for effective implementation of microcomputers in the school. This study examines the implementation of educational computing among 47 science teachers who completed the ENLIST Micros training at a southern university. We present results of formative evaluation for that site. Results indicate that both elementary and secondary teachers benefit from the training program and demonstrate gains in attitudes toward computer use. Participating teachers said that the program met its stated objectives and helped them obtain needed skills. Only 33 percent of these teachers, however, reported using computers one year after the training. In June 1986, the BSCS initiated a follow up to the ENLIST Micros curriculum to

  6. A high-performance data acquisition system for computer-based multichannel analyzer

    International Nuclear Information System (INIS)

    Zhou Xinzhi; Bai Rongsheng; Wen Liangbi; Huang Yanwen

    1996-01-01

    A high-performance data acquisition system applied in the multichannel analyzer is designed with single-chip microcomputer system. The paper proposes the principle and the method of realizing the simultaneous data acquisition, the data pre-processing, and the fast bidirectional data transfer by means of direct memory access based on dual-port RAM as well. The measurement for dead or live time of ADC system can also be implemented efficiently by using it

  7. Program pseudo-random number generator for microcomputers

    International Nuclear Information System (INIS)

    Ososkov, G.A.

    1980-01-01

    Program pseudo-random number generators (PNG) intended for the test of control equipment and communication channels are considered. In the case of 8-bit microcomputers it is necessary to assign 4 words of storage to allocate one random number. The proposed economical algorithms of the random number generation are based on the idea of the ''mixing'' of such quarters of the preceeding random number to obtain the next one. Test results of the PNG are displayed for two such generators. A FORTRAN variant of the PNG is presented along with a program realizing the PNG made on the base of the INTEL-8080 autocode

  8. A gamma cammera image processing system

    International Nuclear Information System (INIS)

    Chen Weihua; Mei Jufang; Jiang Wenchuan; Guo Zhenxiang

    1987-01-01

    A microcomputer based gamma camera image processing system has been introduced. Comparing with other systems, the feature of this system is that an inexpensive microcomputer has been combined with specially developed hardware, such as, data acquisition controller, data processor and dynamic display controller, ect. Thus the process of picture processing has been speeded up and the function expense ratio of the system raised

  9. User's manual for levelized power generation cost using a microcomputer

    International Nuclear Information System (INIS)

    Fuller, L.C.

    1984-08-01

    Microcomputer programs for the estimation of levelized electrical power generation costs are described. Procedures for light-water reactor plants and coal-fired plants include capital investment cost, operation and maintenance cost, fuel cycle cost, nuclear decommissioning cost, and levelized total generation cost. Programs are written in Pascal and are run on an Apple II Plus microcomputer

  10. Microcomputer Applications for Teaching Microeconomic Concepts: Some Old and New Approaches.

    Science.gov (United States)

    Smith, L. Murphy; Smith, L. C., Jr.

    1989-01-01

    Presents microcomputer programs and programing techniques and demonstrates how these programs can be used by teachers to explain economics concepts and to help students make judgments. Each microcomputer application is supplemented by traditional graphic and mathematical analysis. Discusses applications dealing with supply, demand, elasticity,…

  11. Universal microcomputer ABM 80 for data processing and measurement devices control

    International Nuclear Information System (INIS)

    Jagiello, S.; Kozminski, A.; Plominski, M.; Rzymkowski, K.

    1983-01-01

    The main features of the universal microcomputer ABM-80 with microprocessor INTEL 8080 are described. ABM-80 works with the measurer AZAR and the register ERD-102 or with other equipment with similar input/output parameters. Monitor program is an integral part of the microcomputer. (author)

  12. Low background α β measuring and acquisition PC card based on single chip microcomputer 89C51 and Max528 DAC

    International Nuclear Information System (INIS)

    Liu Weihong; Pan Zhongtao; Zhang Liqiong

    1996-01-01

    A low background α β measuring and data acquisition PC card based on 89C51 microcomputer and eight bites eight channels digital to analog converter are introduced. It has four digital threshold adjustments and two high voltage controllers on one card and has functions of processing signals from nuclear detector, such as amplifying, comparing, shaping, coincidence or anti-coincidence, counting and saving data

  13. Microcomputer Simulated CAD for Engineering Graphics.

    Science.gov (United States)

    Huggins, David L.; Myers, Roy E.

    1983-01-01

    Describes a simulated computer-aided-graphics (CAD) program at The Pennsylvania State University. Rationale for the program, facilities, microcomputer equipment (Apple) used, and development of a software package for simulating applied engineering graphics are considered. (JN)

  14. Efficiency determination of whole-body counter by Monte Carlo method, using a microcomputer

    International Nuclear Information System (INIS)

    Fernandes Neto, Jose Maria

    1986-01-01

    The purpose of this investigation was the development of an analytical microcomputer model to evaluate a whole body counter efficiency. The model is based on a modified Sryder's model. A stretcher type geometry along with the Monte Carlo method and a Synclair type microcomputer were used. Experimental measurements were performed using two phantoms, one as an adult and the other as a 5 year old child. The phantoms were made in acrylic and and 99m Tc, 131 I and 42 K were the radioisotopes utilized. Results showed a close relationship between experimental and predicted data for energies ranging from 250 keV to 2 MeV, but some discrepancies were found for lower energies. (author)

  15. X-ray diffraction identification of clay minerals by microcomputer

    International Nuclear Information System (INIS)

    Rodrigues, S.; Imasava, F.J.

    1988-01-01

    The identification of clay minerals by X-ray powder diffraction are done by searching an unknown pattern with a file of standard X-ray diffraction patterns. For this searching done by hand is necessary a long time. This paper shows a program in ''Basic'' language to be utilized in microcomputers for the math of the unknown pattern, using the high velocity of comparison of the microcomputer. A few minutes are used for the match. (author) [pt

  16. Graphics of (X,Y) spectrum for microcomputer; Graficado de espectro (X,Y) para microcomputadora

    Energy Technology Data Exchange (ETDEWEB)

    Macias B, L.R

    1991-08-15

    When carrying out diffraction works is frequently required to visualize the spectra of the data obtained in order to analyzing them. The design for the obtaining of data in the neutron diffractometer by means of the microcomputer allows to store them in a file by means of the one which transferring to the CYBER system so that by means of its utilities the mentioned spectrum is observed in a graph. In diffraction works, it is sought to study crystalline materials by means of the execution of the Bragg law by that the mounted sample on the diffractometer is subjected to a scanning of the sample with a radiation of a well-known wavelength and this way varying the angles, the corresponding interplanar distances are determined. The main objective of this work, is starting of a data set generated by the diffractometer, to generate the graph of the corresponding (X,Y) spectra in visual form in the screen of a microcomputer and if it is required, to obtain the graph in printed form by means of the same computer program for microcomputer. (Author)

  17. History Microcomputer Games: Update 2.

    Science.gov (United States)

    Sargent, James E.

    1985-01-01

    Provides full narrative reviews of B-1 Nuclear Bomber (Avalon, 1982); American History Adventure (Social Science Microcomputer Review Software, 1985); Government Simulations (Prentice-Hall, 1985); and The Great War, FDR and the New Deal, and Hitler's War, all from New Worlds Software, 1985. Lists additional information on five other history and…

  18. Development and implementation of a low cost micro computer system for LANDSAT analysis and geographic data base applications

    Science.gov (United States)

    Faust, N.; Jordon, L.

    1981-01-01

    Since the implementation of the GRID and IMGRID computer programs for multivariate spatial analysis in the early 1970's, geographic data analysis subsequently moved from large computers to minicomputers and now to microcomputers with radical reduction in the costs associated with planning analyses. Programs designed to process LANDSAT data to be used as one element in a geographic data base were used once NIMGRID (new IMGRID), a raster oriented geographic information system, was implemented on the microcomputer. Programs for training field selection, supervised and unsupervised classification, and image enhancement were added. Enhancements to the color graphics capabilities of the microsystem allow display of three channels of LANDSAT data in color infrared format. The basic microcomputer hardware needed to perform NIMGRID and most LANDSAT analyses is listed as well as the software available for LANDSAT processing.

  19. New generation of single-chip microcomputers focused on cost performance

    Energy Technology Data Exchange (ETDEWEB)

    Akao, Y.; Iwashita, H. (Hitachi, Ltd., Tokyo (Japan))

    1993-06-01

    A single-chip microcomputer which incorporates a CPU (central processing unit), memory, and peripheral functions in one chip has been increasingly applied to various fields as the heart of electronic equipment in terms of its economy, compactness, lightness, and suitability for mass production. In response to a wide variety of needs, a lineup must have substantial breadth with regard to performance, on-chip memory capacity, on-chip peripheral functions, operating voltage, and packaging. In particular, low-voltage high-speed operation, high integration, expanded address space, and improved software productivity, which are required for mobile communication terminals, are the common needs for single-chip microcomputers. In accordance with these needs, Hitachi has been actively developing new products. The present paper introduces Hitachi's lineup of single-chip microcomputers. 10 figs., 1 tab.

  20. The new Aladdin control system

    International Nuclear Information System (INIS)

    Stott, J.P.; Eisert, D.E.

    1990-01-01

    The preliminary design of the new control system for the Aladdin electron-storage-ring light source was described at the Los Alamos workshop and an updated report was given at the Villars conference. The new system is now almost completely installed and this paper is a final report on the project. The major features of the system are the following: commercial hardware is used throughout the computer, network and microcomputer systems; the operator consoles and the device-control microcomputers are linked by Ethernet; VAXstations with keyboard and track-ball input devices are used in the operator consoles; the microcomputers use 68000-based single-board computers and VMEbus backplanes; the main magnet power supplies contain intelligent controllers which are linked to a microcomputer by a multidrop serial link; the microcomputer software is developed on the VAXstations; it is downloaded into RAM and debugged over the Ethernet before being burned into EPROMs for operational use. This paper describes the design of the system, highlighting changes from the previous proposals, and discusses the aspects which allowed the control system of an operating facility to be rebuilt without requiring or causing any significant downtime. The performance of the new system and possible future improvements are also discussed. (orig.)

  1. X-ray TV image analyzer with built-in microcomputer

    International Nuclear Information System (INIS)

    Takizawa, Masaomi; Maruyama, Kiyoshi; Fujii, Tadashige; Hirayama, Jiro

    1979-01-01

    X-ray TV system (XTV) is indispensable for inspections such as cardiac catheter inspection and urinary tract inspection as well as gastrointestinal tract inspection. The XTV has been so far employed for observing the appropriate time for making images and grasping the position to be photographed in X-ray photographing. However, taking the considerable amount of radiation exposure given to patients during fluoroscopy into account, it is better to utilize the information within living bodies more effectively. The experiments to record fluoroscopic images using VTRs (video tape recorder) and to analyze the moving pictures by means of VTR playback have been carried out by videodensitometry and videoplanimetry. The authors have produced an image analyzing system of XTV, which incorporates a microprocessor, on the basis of the experiences of minicomputer-assisted videodensitometry. The system uses the digital frame memory controlled by a microcomputer, and transfers the data from this memory to the main memory by the command from the microcomputer. This alloys to sample freely image data in any direction. To the microprocessor memory, 16 kbytes EPROM (erasable and programmable read only memory) and 16 kbytes RAM (random access memory) are attached. At present, the programs for the measurement of such as the inspection of local pulmonary function and the change of urethrae in urination accompanying the imaging of bladders are being developed. Some results of videodensitometry under test are presented. Wider applications for future are expected in the discussions. (Wakatsuki, Y.)

  2. Microcomputers and computer networks

    International Nuclear Information System (INIS)

    Owens, J.L.

    1976-01-01

    Computers, for all their speed and efficiency, have their foibles and failings. Until the advent of minicomputers, users often had to supervise their programs personally to make sure they executed correctly. Minicomputers could take over some of these chores, but they were too expensive to be dedicated to any but the most vital services. Inexpensive, easily programmed microcomputers are easing this limitation, and permitting a flood of new applications. 3 figures

  3. CEGB philosophy and experience with fault-tolerant micro-computer application for power plant controls

    International Nuclear Information System (INIS)

    Clinch, D.A.L.

    1986-01-01

    From the mid-1960s until the late 1970s, automatic modulating control of the main boiler plant on CEGB fossil-fired power stations was largely implemented with hard wired electronic equipment. Mid-way through this period, the CEGB formulated a set of design requirements for this type of equipment; these laid particular emphasis on the fault tolerance of a control system and specified the nature of the interfaces with a control desk and with plant regulators. However, the automatic control of an Advanced Gas Cooled Reactor (AGR) is based upon measured values which are derived by processing a large number of thermocouple signals. This is more readily implemented digitally than with hard-wired equipment. Essential to the operation of an AGR power station is a data processing (DP) computer for monitoring the plant; so the first group of AGR power stations, designed in the 1960s, employed their DP computers for modulating control. Since the late 1970s, automatic modulating control of major plants, for new power stations and for re-fits on established power stations, has been implemented with micro-computers. Wherever practicable, the policy formulated earlier for hard-wired equipment has been retained, particularly in respect of the interfaces. This policy forms the foundation of the fault tolerance of these micro-computer systems

  4. Inside marginal adaptation of crowns by X-ray micro-computed tomography

    International Nuclear Information System (INIS)

    Dos Santos, T. M.; Lima, I.; Lopes, R. T.; Author, S. B. Jr.

    2015-01-01

    The objective of this work was to access dental arcade by using X-ray micro-computed tomography. For this purpose high resolution system was used and three groups were studied: Zirkonzahn CAD-CAM system, IPS e.max Press, and metal ceramic. The three systems assessed in this study showed results of marginal and discrepancy gaps clinically accepted. The great result of 2D and 3D evaluations showed that the used technique is a powerful method to investigate quantitative characteristics of dental arcade. (authors)

  5. Inside marginal adaptation of crowns by X-ray micro-computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Dos Santos, T. M.; Lima, I.; Lopes, R. T. [Nuclear Instrumentation Laboratory, Nuclear Engineering Program, Federal University of Rio de Janeiro, RJ, (Brazil); Author, S. B. Jr. [Department of Physics, Colorado State University, Ft. Collins, CO 80523, (United States)

    2015-07-01

    The objective of this work was to access dental arcade by using X-ray micro-computed tomography. For this purpose high resolution system was used and three groups were studied: Zirkonzahn CAD-CAM system, IPS e.max Press, and metal ceramic. The three systems assessed in this study showed results of marginal and discrepancy gaps clinically accepted. The great result of 2D and 3D evaluations showed that the used technique is a powerful method to investigate quantitative characteristics of dental arcade. (authors)

  6. Computer-based nuclear radiation detection and instrumentation teaching laboratory system

    International Nuclear Information System (INIS)

    Ellis, W.H.; He, Q.

    1993-01-01

    The integration of computers into the University of Florida's Nuclear Engineering Sciences teaching laboratories is based on the innovative use of MacIntosh 2 microcomputers, IEEE-488 (GPIB) communication and control bus system and protocol, compatible modular nuclear instrumentation (NIM) and test equipment, LabVIEW graphics and applications software, with locally prepared, interactive, menu-driven, HyperCard based multi-exercise laboratory instruction sets and procedures. Results thus far have been highly successful with the majority of the laboratory exercises having been implemented

  7. A low-cost multichannel pulse-height analyzer PHA 256 using single-chip microcomputer

    International Nuclear Information System (INIS)

    Koehler, M.; Meiling, W.

    1985-01-01

    The PHA 256 multichannel analyzer on the base of the U8820 single-chip microcomputer applied for radiation measurements, for example in monitoring systems with scintillation detectors, is described. The analyzer contains a power supply unit and 7 boards, namely, the processor board; data and program memory; 8-bit analog-to-digital converter; driver to display device; keyboard with 23 function keys; pulse amplifier and high-voltage supply (up to 2 kV). Software used provides preprocessing of spectra supported by following functions: addition and subtraction of different spectra, spectrum monitoring by use of a 5-point-algorithm, calculation of peak areas with linearly interpolated background

  8. Prototype particulate stack sampler with single-cut nozzle and microcomputer calculating/display system

    International Nuclear Information System (INIS)

    Eler, J.C.; Littlefield, L.G.; Tillery, M.I.

    1979-01-01

    A prototype particulate stack sampler (PPSS) has been developed to improve on the existing EPA Method 5 sampling apparatus. Its primary features are (1) higher sampling rate (56 1/min); (2) display (on demand) of all required variables and calculated values by a microcomputer-based calculating and display system; (3) continuous stack gas moisture determination; (4) a virtual impactor nozzle with 3 μm mass median diameter cutpoint which collects fine and coarse particle fractions on separate glass fiber filters; (5) a variable-area inlet to maintain isokinetic sampling conditions; and (6) conversion to stainless steel components from the glass specified by EPA Method 5. The basic sampling techniques of EPA Method 5 have been retained; however, versatility in the form of optional in-stack filters and general modernization of the stack sampler have been provided in the prototype design. Laboratory testing with monodisperse dye aerosols has shown the present variable inlet, virtual impactor nozzle to have a collection efficiency which is less than 77% and significant wall losses. This is primarily due to lack of symmetry in this rectangular jet impactor and short transition lengths dictated by physical design constraints (required passage of the nozzle through a 7.6 cm (3 in) diameter stack port). Electronic components have shown acceptable service in laboratory testing although no field testing of the prototype under a broad range of temperature, humidity, and SO 2 concentration has been undertaken

  9. Facility/equipment performance evaluation using microcomputer simulation analysis

    International Nuclear Information System (INIS)

    Chockie, A.D.; Hostick, C.J.

    1985-08-01

    A computer simulation analysis model was developed at the Pacific Northwest Laboratory to assist in assuring the adequacy of the Monitored Retrievable Storage facility design to meet the specified spent nuclear fuel throughput requirements. The microcomputer-based model was applied to the analysis of material flow, equipment capability and facility layout. The simulation analysis evaluated uncertainties concerning both facility throughput requirements and process duration times as part of the development of a comprehensive estimate of facility performance. The evaluations provided feedback into the design review task to identify areas where design modifications should be considered

  10. Data processing system with a micro-computer for high magnetic field tokamak, TRIAM-1

    International Nuclear Information System (INIS)

    Kawasaki, Shoji; Nakamura, Kazuo; Nakamura, Yukio; Hiraki, Naoharu; Toi, Kazuo

    1981-01-01

    A data processing system was designed and constructed for the purpose of analyzing the data of the high magnetic field tokamak TRIAM-1. The system consists of a 10-channel A-D converter, a 20 K byte memory (RAM), an address bus control circuit, a data bus control circuit, a timing pulse and control signal generator, a D-A converter, a micro-computer, and a power source. The memory can be used as a CPU memory except at the time of sampling and data output. The out-put devices of the system are an X-Y recorder and an oscilloscope. The computer is composed of a CPU, a memory and an I/O part. The memory size can be extended. A cassette tape recorder is provided to keep the programs of the computer. An interface circuit between the computer and the tape recorder was designed and constructed. An electric discharge printer as an I/O device can be connected. From TRIAM-1, the signals of magnetic probes, plasma current, vertical field coil current, and one-turn loop voltage are fed into the processing system. The plasma displacement calculated from these signals is shown by one of I/O devices. The results of test run showed good performance. (Kato, T.)

  11. Data processing system with a micro-computer for high magnetic field tokamak, TRIAM-1

    Energy Technology Data Exchange (ETDEWEB)

    Kawasaki, S; Nakamura, K; Nakamura, Y; Hiraki, N; Toi, K [Kyushu Univ., Fukuoka (Japan). Research Inst. for Applied Mechanics

    1981-02-01

    A data processing system was designed and constructed for the purpose of analyzing the data of the high magnetic field tokamak TRIAM-1. The system consists of a 10-channel A-D converter, a 20 K byte memory (RAM), an address bus control circuit, a data bus control circuit, a timing pulse and control signal generator, a D-A converter, a micro-computer, and a power source. The memory can be used as a CPU memory except at the time of sampling and data output. The out-put devices of the system are an X-Y recorder and an oscilloscope. The computer is composed of a CPU, a memory and an I/O part. The memory size can be extended. A cassette tape recorder is provided to keep the programs of the computer. An interface circuit between the computer and the tape recorder was designed and constructed. An electric discharge printer as an I/O device can be connected. From TRIAM-1, the signals of magnetic probes, plasma current, vertical field coil current, and one-turn loop voltage are fed into the processing system. The plasma displacement calculated from these signals is shown by one of I/O devices. The results of test run showed good performance.

  12. Reading Diagnosis via the Microcomputer (The Printout).

    Science.gov (United States)

    Weisberg, Renee; Balajthy, Ernest

    1989-01-01

    Examines and evaluates microcomputer software designed to assist in diagnosing students' reading abilities and making instructional decisions. Claims that existing software shows valuable potential when used sensibly and critically by trained reading clinicians. (MM)

  13. Microcomputers, Model Rockets, and Race Cars.

    Science.gov (United States)

    Mirus, Edward A., Jr.

    1985-01-01

    The industrial education orientation program at Wisconsin School for the Deaf (WSD) presents problem-solving situations to all seventh- and eighth-grade hearing-impaired students. WSD developed user-friendly microcomputer software to guide students individually through complex computations involving model race cars and rockets while freeing…

  14. Dose calculation in brachytherapy with microcomputers

    International Nuclear Information System (INIS)

    Elbern, A.W.

    1989-01-01

    The computer algorithms, that allow the calculation of brachytherapy doses and its graphic representation for implants, using programs developed for Pc microcomputers are presented. These algorithms allow to localized the sources in space, from their projection in radiographics images and trace isodose counter. (C.G.C.) [pt

  15. Evaluation of Five Microcomputer CAD Packages.

    Science.gov (United States)

    Leach, James A.

    1987-01-01

    Discusses the similarities, differences, advanced features, applications and number of users of five microcomputer computer-aided design (CAD) packages. Included are: "AutoCAD (V.2.17)"; "CADKEY (V.2.0)"; "CADVANCE (V.1.0)"; "Super MicroCAD"; and "VersaCAD Advanced (V.4.00)." Describes the…

  16. Derandomizing buffer and microcomputer memory for the use of a fast MWPC image memory

    International Nuclear Information System (INIS)

    Skvaril, J.

    1986-01-01

    We have developed a special derandomizing buffer memory for MWPC imaging which makes it possible to use a microcomputer memory in DMA mode. The buffer regulates an input data stream (X and Y coordinates of a event) into a microcomputer memory with practically no data losses. The advantages of this approach are (a) no special histogramming memory is needed and (b) a resultant image is in the memory space of the microcomputer used and can be immediately processed. (orig.)

  17. Scheduling nursing personnel on a microcomputer.

    Science.gov (United States)

    Liao, C J; Kao, C Y

    1997-01-01

    Suggests that with the shortage of nursing personnel, hospital administrators have to pay more attention to the needs of nurses to retain and recruit them. Also asserts that improving nurses' schedules is one of the most economic ways for the hospital administration to create a better working environment for nurses. Develops an algorithm for scheduling nursing personnel. Contrary to the current hospital approach, which schedules nurses on a person-by-person basis, the proposed algorithm constructs schedules on a day-by-day basis. The algorithm has inherent flexibility in handling a variety of possible constraints and goals, similar to other non-cyclical approaches. But, unlike most other non-cyclical approaches, it can also generate a quality schedule in a short time on a microcomputer. The algorithm was coded in C language and run on a microcomputer. The developed software is currently implemented at a leading hospital in Taiwan. The response to the initial implementation is quite promising.

  18. Microcomputer-assisted transmission of disaster data by cellular telephone.

    Science.gov (United States)

    Wigder, H N; Fligner, D J; Rivers, D; Hotch, D

    1989-01-01

    Voice communication of information during disasters is often inadequate. In particular, simultaneous transmission by multiple callers on the same frequency can result in blocked transmissions and miscommunications. In contrast, nonvoice transmission of data requires less time than does voice communication of the same data, and may be more accurate. We conducted a pilot study to test the feasibility of a microcomputer assisted communication (MAC) network linking the disaster scene and the command hospital. The radio chosen to transmit data from the field disaster site to the command hospital was a cellular telephone connected to the microcomputer by modem. Typed communications between the microcomputer operators enabled dialogue between the disaster site and the hospitals. A computer program using commercially available software (Symphony by Lotus, Inc.) was written to allow for data entry, data transmission, and reports. Patient data, including age, sex, severity of injury, identification number, major injuries, and hospital destination were successfully transmitted from the disaster site command post to the command hospital. This pilot test demonstrated the potential applicability of MAC for facilitating transmission of patient data during a disaster.

  19. Microcomputer interfacing and applications

    CERN Document Server

    Mustafa, M A

    1990-01-01

    This is the applications guide to interfacing microcomputers. It offers practical non-mathematical solutions to interfacing problems in many applications including data acquisition and control. Emphasis is given to the definition of the objectives of the interface, then comparing possible solutions and producing the best interface for every situation. Dr Mustafa A Mustafa is a senior designer of control equipment and has written many technical articles and papers on the subject of computers and their application to control engineering.

  20. Microcomputers in a Beginning Tertiary Physics Course.

    Science.gov (United States)

    Pearce, J. M.; O'Brien, R.

    1986-01-01

    Describes a college-level physics course which focuses on both physics knowledge/skills and use of microcomputers. Types of experiments done with the computers and how students use the computers to treat data are considered. (JN)

  1. Microcomputer Assisted Interpretative Reporting of Sequential Creatine Kinase (CK) and Lactate Dehydrogenase (LDH) Isoenzyme Determination

    Science.gov (United States)

    Talamo, Thomas S.; Losos, Frank J.; Mercer, Donald W.

    1984-01-01

    We have developed a microcomputer based system for interpretative reporting of creatine kinase (CK) and lactate dehydrogenase (LDH) isoenzyme studies. Patient demographic data and test results (total CK, CK-MB, LD-1, and LD-2) are entered manually through the keyboard. The test results are compared with normal range values and an interpretative report is generated. This report consists of all pertinent demographic information with a graphic display of up to 12 previous CK and LDH isoenzyme determinations. Diagnostic interpretative statements are printed beneath the graphic display following analysis of previously entered test results. The combination of graphic data display and interpretations based on analysis of up to 12 previous specimens provides useful and accurate information to the cardiologist.

  2. A microcomputer program for energy assessment and aggregation using the triangular probability distribution

    Science.gov (United States)

    Crovelli, R.A.; Balay, R.H.

    1991-01-01

    A general risk-analysis method was developed for petroleum-resource assessment and other applications. The triangular probability distribution is used as a model with an analytic aggregation methodology based on probability theory rather than Monte-Carlo simulation. Among the advantages of the analytic method are its computational speed and flexibility, and the saving of time and cost on a microcomputer. The input into the model consists of a set of components (e.g. geologic provinces) and, for each component, three potential resource estimates: minimum, most likely (mode), and maximum. Assuming a triangular probability distribution, the mean, standard deviation, and seven fractiles (F100, F95, F75, F50, F25, F5, and F0) are computed for each component, where for example, the probability of more than F95 is equal to 0.95. The components are aggregated by combining the means, standard deviations, and respective fractiles under three possible siutations (1) perfect positive correlation, (2) complete independence, and (3) any degree of dependence between these two polar situations. A package of computer programs named the TRIAGG system was written in the Turbo Pascal 4.0 language for performing the analytic probabilistic methodology. The system consists of a program for processing triangular probability distribution assessments and aggregations, and a separate aggregation routine for aggregating aggregations. The user's documentation and program diskette of the TRIAGG system are available from USGS Open File Services. TRIAGG requires an IBM-PC/XT/AT compatible microcomputer with 256kbyte of main memory, MS-DOS 3.1 or later, either two diskette drives or a fixed disk, and a 132 column printer. A graphics adapter and color display are optional. ?? 1991.

  3. Dictionary of microelectronics and microcomputer technology

    International Nuclear Information System (INIS)

    Attiyate, Y.H.; Shah, R.R.

    1984-01-01

    This bilingual dictionary (German-English and English-German) is to give the general public a clearer idea of the terminology of microelectronics, microcomputers, data processing, and computer science. Each part contains about 7500 terms frequently encountered in practice, about 2000 of which are supplemented by precise explanations. (orig./HP) [de

  4. Micro-computed tomography newly developed for in vivo small animal imaging

    International Nuclear Information System (INIS)

    Arai, Yoshinori; Ninomiya, Tadashi; Kato, Takafumi; Masuda, Yuji

    2005-01-01

    The aim of this paper is to report a newly developed micro-computed tomography system for in vivo use. The system was composed of a micro-focus X-ray tube and an image intensifier (I.I.), both of which rotated around the object stage. A guinea pig and a rat were examined. The anesthetized animal was set on the secure object stage. Images of the head of the guinea pig and the tibia knee joint of the rat were taken. In addition, an image of the rat's tail was taken. The reconstruction and the image viewing were carried out using I-View software. The voxel matrix was 512 x 512 x 384. The voxel sizes ranged from 10 x 10 x 10 μm to 100 x 100 x 100 μm. The exposure time was 17 s, and the reconstruction time was 150 s. The head of the guinea pig and the tibia/knee joint of the rat were observed clearly under 100-μm and 30μm voxels, respectively. The trabecular bone of the tail was also observed clearly under a 10 μm voxel. The newly developed micro-computed tomography system makes it possible to obtain images of anesthetized animals set on a secure object stage. Clear bone images of the small animals could be obtained within a short time. (author)

  5. Microcomputers and the Individual Practitioner: A Review of the Literature in Psychology and Psychiatry.

    Science.gov (United States)

    Levitan, Karen B.; And Others

    1985-01-01

    Presents findings of a literature review from December 1983 to January 1984, exploring microcomputer uses and needs of practitioners in psychology and psychiatry. Covers overview and history of information technology requirements of the practitioner community and discusses hardware and software systems, as well as issues and barriers associated…

  6. Psychology of computer use: IX. A menu of self-administered microcomputer-based neurotoxicology tests

    Science.gov (United States)

    Kennedy, R. S.; Baltzley, D. R.; Wilkes, R. L.; Kuntz, L. A.

    1989-01-01

    This study examined the feasibility of repeated self-administration of a newly developed battery of mental acuity tests which may have application in screening for fitness-for-duty or for persons who may be exposed to environmental stress, toxic agents, or disease. 16 subjects self-administered 18 microcomputer-based tests (13 new, 5 "core"), without proctors, over 10 sessions. The hardware performed well throughout the study and the tests appeared to be easily self-administered. Stabilities and reliabilities of the tests from the "core" battery were comparable to those obtained previously under more controlled experimental conditions. Eight of the new tests exceeded minimum criteria for metric and practical requirements and can be recommended as additions to the menu. Although the average retest reliability was high, cross-correlations between tests were low, implying factorial diversity. The menu can be used to form batteries with flexible total testing time which are likely to tap different mental processes and functions.

  7. Shaping ability of the conventional nickel-titanium and reciprocating nickel-titanium file systems: a comparative study using micro-computed tomography.

    Science.gov (United States)

    Hwang, Young-Hye; Bae, Kwang-Shik; Baek, Seung-Ho; Kum, Kee-Yeon; Lee, WooCheol; Shon, Won-Jun; Chang, Seok Woo

    2014-08-01

    This study used micro-computed tomographic imaging to compare the shaping ability of Mtwo (VDW, Munich, Germany), a conventional nickel-titanium file system, and Reciproc (VDW), a reciprocating file system morphologically similar to Mtwo. Root canal shaping was performed on the mesiobuccal and distobuccal canals of extracted maxillary molars. In the RR group (n = 15), Reciproc was used in a reciprocating motion (150° counterclockwise/30° clockwise, 300 rpm); in the MR group, Mtwo was used in a reciprocating motion (150° clockwise/30° counterclockwise, 300 rpm); and in the MC group, Mtwo was used in a continuous rotating motion (300 rpm). Micro-computed tomographic images taken before and after canal shaping were used to analyze canal volume change and the degree of transportation at the cervical, middle, and apical levels. The time required for canal shaping was recorded. Afterward, each file was analyzed using scanning electron microscopy. No statistically significant differences were found among the 3 groups in the time for canal shaping or canal volume change (P > .05). Transportation values of the RR and MR groups were not significantly different at any level. However, the transportation value of the MC group was significantly higher than both the RR and MR groups at the cervical and apical levels (P file deformation was observed for 1 file in group RR (1/15), 3 files in group MR (3/15), and 5 files in group MC (5/15). In terms of shaping ability, Mtwo used in a reciprocating motion was not significantly different from the Reciproc system. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  8. A long distance voice transmission system based on the white light LED

    Science.gov (United States)

    Tian, Chunyu; Wei, Chang; Wang, Yulian; Wang, Dachi; Yu, Benli; Xu, Feng

    2017-10-01

    A long distance voice transmission system based on a visible light communication technology (VLCT) is proposed in the paper. Our proposed system includes transmitter, receiver and the voice signal processing of single chip microcomputer. In the compact-sized LED transmitter, we use on-off-keying and not-return-to-zero (OOK-NRZ) to easily realize high speed modulation, and then systematic complexity is reduced. A voice transmission system, which possesses the properties of the low-noise and wide modulation band, is achieved by the design of high efficiency receiving optical path and using filters to reduce noise from the surrounding light. To improve the speed of the signal processing, we use single chip microcomputer to code and decode voice signal. Furthermore, serial peripheral interface (SPI) is adopted to accurately transmit voice signal data. The test results of our proposed system show that the transmission distance of this system is more than100 meters with the maximum data rate of 1.5 Mbit/s and a SNR of 30dB. This system has many advantages, such as simple construction, low cost and strong practicality. Therefore, it has extensive application prospect in the fields of the emergency communication and indoor wireless communication, etc.

  9. Machine Distribution. Microcomputing Working Papers Series.

    Science.gov (United States)

    Drexel Univ., Philadelphia, PA. Microcomputing Program.

    During the academic year 1983-84, Drexel University instituted a new policy requiring all incoming students to have access to a microcomputer. The computer chosen to fulfill this requirement was the Macintosh from Apple Computer, Inc. This paper provides a brief description of the process undertaken to select the appropriate computer (i.e.,…

  10. Microcomputer-controlled remote pipetter: design and evaluation of a prototype system

    International Nuclear Information System (INIS)

    Goeringer, D.E.; Klatt, L.N.

    1981-04-01

    A prototype remote pipetter has been designed and evaluated. The principle of operation for the pipetter is the displacement of liquid via a calibrated, screw-driven plunger. Variably sized aliquots of 1 to 1000 μ1 can be delivered. A stepping motor is used to move the plunger, and its position is verified with a linear variable differential transformer. The unit is controlled by a microcomputer. Besides the required operation sequences and error checking, a self calibration check has been designed into the software. Accuracy and precision of plunger movements corresponding to delivery of aliquots ranging from 100 to 500 μ1 are 0.3 μ1 and 0.4 μ1 respectively. Nonlinearity over the full range of plunger travel is 0.02%

  11. Assembly language program design used in model DD80 multifunction microcomputer multichannel analyzer

    Energy Technology Data Exchange (ETDEWEB)

    Yiziang, Wei; Ying, Chen; Xide, Zhao

    1985-05-01

    This paper describes the structures, features, flowcharts and design considerations of assembly language program used in Model DD80 (FH1920) multifunction microcomputer multichannel analyzer. On the Model TRS-80 (I) microcomputer with DD80 multifunction interface this program can be used in spectrum data acquisition, spectrum live display and some spectrum data processing.

  12. The Design Of The Ultrasonic Nondestructive Testing System Based On The EMAT

    OpenAIRE

    Cheng Huan Xin; Meng Xiang Yong; Li Jing; Cheng Li

    2016-01-01

    This paper introduces a kind of based on the electromagnetic acoustic transducer (EMAT) metal pipeline detection system, fusion of two dimensional orientation, shape unique technological innovation, implementation of various metal pipe wall corrosion situation of rapid, accurate, fully automated non-destructive testing.In the aspect of hardware design, single-chip microcomputer control was achieved by C language programming the launch of the pulse signal. Pulse signal was sent to launch circu...

  13. Automated System Marketplace 1994.

    Science.gov (United States)

    Griffiths, Jose-Marie; Kertis, Kimberly

    1994-01-01

    Reports results of the 1994 Automated System Marketplace survey based on responses from 60 vendors. Highlights include changes in the library automation marketplace; estimated library systems revenues; minicomputer and microcomputer-based systems; marketplace trends; global markets and mergers; research needs; new purchase processes; and profiles…

  14. System Analysis and Risk Assessment (SARA) system

    International Nuclear Information System (INIS)

    Krantz, E.A.; Russell, K.D.; Stewart, H.D.; Van Siclen, V.S.

    1986-01-01

    Utilization of Probabilistic Risk Assessment (PRA) related information in the day-to-day operation of plant systems has, in the past, been impracticable due to the size of the computers needed to run PRA codes. This paper discusses a microcomputer-based database system which can greatly enhance the capability of operators or regulators to incorporate PRA methodologies into their routine decision making. This system is called the System Analysis and Risk Assessment (SARA) system. SARA was developed by EG and G Idaho, Inc. at the Idaho National Engineering Laboratory to facilitate the study of frequency and consequence analyses of accident sequences from a large number of light water reactors (LWRs) in this country. This information is being amassed by several studies sponsored by the United States Nuclear Regulatory Commission (USNRC). To meet the need of portability and accessibility, and to perform the variety of calculations necessary, it was felt that a microcomputer-based system would be most suitable

  15. Microcomputers take over in off-shore process

    Energy Technology Data Exchange (ETDEWEB)

    Claricoates, J

    1978-10-01

    The special capabilities and adaptability of microcomputers are typically demonstrated by the use of them on Mobil Exploration, Norway, Inc.'s Statfjord A Condeep platform. One of the unique features of offshore oil production is that so many different operations are conducted in a very confined space. On Statfjord A drilling, production, storage of crude oil, gas compression for sale or reinjection, custody transfer, generation and distribution of a significant amount of electric power, a hotel facility, and flight operations, all have to be accommodated and controlled. Superimposed on these are comprehensive fire detection and shutdown systems. In such a highly complex, densely packed, and highly interactive environment, a supervisory control and data acquisition system (SCADA) by providing coordinated and easily read displays, better records for alarm analysis, and possibly suggesting corrective action when a fault does occur, is an essential aid to an operator, whose decisions must always by correct.

  16. A perspective on software quality management using microcomputers in safety-related activities

    International Nuclear Information System (INIS)

    Braudt, T.E.; Pratl, M.J.

    1992-01-01

    Software Quality Management, often referred to as Software Quality Assurance or SQA, is a belief or mindset in establishing and protecting the value of software as a corporate asset. It is often expressed in terms of a basic methodology for ensuring adequate controls to maintain the integrity of the configuration of a software system. SQA applies to all activities germane to the acquisition, installation, operation and maintenance of software systems and is key to calculational accuracy and completeness in an Engineering and/or Scientific arena. Simply, it is a vital management tool for ensuring cost-effective utilization of information management resources. The basis principles of SQA apply equally to software applications in microcomputer environments and mainframe environments alike. Regardless of the nature of the computing environment, divisions of responsibilities or logistical difficulties, quality measures must be established to ensure accuracy, completeness, reliability, and reproducibility of the results of the software application. The extent to which these measures are applied should be based upon regulation, economics and practicality

  17. Application of single-chip microcomputer to portable radon and radon daughters monitor

    International Nuclear Information System (INIS)

    Meng Yecheng; Huang Zhanyun; She Chengye

    1992-01-01

    Application of single-chip microcomputer to portable radon and radon daughters monitor is introduced in this paper. With the single-chip microcomputer automation comes into effect in the process from sampling to measuring of radon and radon daughters. The concentrations of radon and radon daughters can be easily shown when the conversion coefficients are pre-settled before the measurement. Moreover, the principle and design are briefly discussed according to the characteristics of the monitor

  18. Micro-computed tomographic comparison of nickel-titanium rotary versus traditional instruments in C-shaped root canal system.

    Science.gov (United States)

    Yin, Xingzhe; Cheung, Gary Shun-Pan; Zhang, Chengfei; Masuda, Yoshiko Murakami; Kimura, Yuichi; Matsumoto, Koukichi

    2010-04-01

    The purpose of this study was to assess the efficacy of instrumentation of C-shaped canals with ProTaper rotary system and traditional instruments by using micro-computed tomography (micro-CT). Twenty-four mandibular molars with C-shaped canals were selected in pairs and sorted equally into 2 groups, which were assigned for instrumentation by ProTaper rotary system (ProTaper group) or by K-files and Gates-Glidden burs (Hand Instrument group). Three-dimensional images were constructed by micro-CT. The volume of dentin removed, uninstrumented canal area, time taken for instrumentation, and iatrogenic error of instrumentation were investigated. Hand Instrument group showed greater amount of volumetric dentin removal and left less uninstrumented canal area than ProTaper group (P ProTaper group than for Hand Instrument group (P Hand Instrument group than for ProTaper group. It was concluded that ProTaper rotary system maintained the canal curvature with speediness and few procedural errors, whereas traditional instrumentation can clean more canal surface. Copyright (c) 2010 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  19. Print Station Operation. Microcomputing Working Paper Series.

    Science.gov (United States)

    Wozny, Lucy Anne

    During the academic year 1983-84, Drexel University instituted a new policy requiring all incoming students to have access to a microcomputer. The computer chosen to fulfill this requirement was the Macintosh from Apple Computer, Inc. Although this requirement put an additional financial burden on the Drexel student, the university administration…

  20. [Comparison of effectiveness and safety between Twisted File technique and ProTaper Universal rotary full sequence based on micro-computed tomography].

    Science.gov (United States)

    Chen, Xiao-bo; Chen, Chen; Liang, Yu-hong

    2016-02-18

    To evaluate the efficacy and security of two type of rotary nickel titanium system (Twisted File and ProTaper Universal) for root canal preparation based on micro-computed tomography(micro-CT). Twenty extracted molars (including 62 canals) were divided into two experimental groups and were respectively instrumented using Twisted File rotary nickel titanium system (TF) and ProTaper Universal rotary nickel titanium system (PU) to #25/0.08 following recommended protocol. Time for root canal instrumentation (accumulation of time for every single file) was recorded. The 0-3 mm root surface from apex was observed under an optical stereomicroscope at 25 × magnification. The presence of crack line was noted. The root canals were scanned with micro-CT before and after root canal preparation. Three-dimensional shape images of canals were reconstructed, calculated and evaluated. The amount of canal central transportation of the two groups was calculated and compared. The shorter preparation time [(0.53 ± 0.14) min] was observed in TF group, while the preparation time of PU group was (2.06 ± 0.39) min (Pvs. (0.097 ± 0.084) mm, P<0.05]. No instrument separation was observed in both the groups. Cracks were not found in both the groups either based in micro-CT images or observation under an optical stereomicroscope at 25 × magnification. Compared with ProTaper Universal, Twisted File took less time in root canal preparation and exhibited better shaping ability, and less canal transportation.

  1. SEAPATH: A microcomputer code for evaluating physical security effectiveness using adversary sequence diagrams

    International Nuclear Information System (INIS)

    Darby, J.L.

    1986-01-01

    The Adversary Sequence Diagram (ASD) concept was developed by Sandia National Laboratories (SNL) to examine physical security system effectiveness. Sandia also developed a mainframe computer code, PANL, to analyze the ASD. The authors have developed a microcomputer code, SEAPATH, which also analyzes ASD's. The Authors are supporting SNL in software development of the SAVI code; SAVI utilizes the SEAPATH algorithm to identify and quantify paths

  2. 1985 seminar on power plant digital control and fault-tolerant microcomputers: proceedings

    International Nuclear Information System (INIS)

    Divakaruni, S.M.

    1986-09-01

    An EPRI Seminar to address Power Plant Digital Controls and Fault-Tolerant Microcomputers Technology was hosted by Arizona Public Service Company in Phoenix, Arizona on April 9-12, 1986. The attendees represented a broad spectrum of US and foreign utilities, architect and consulting firms, and NSSS and computer system hardware vendors. These proceedings contain the text of the formal presentations as well as the papers and slides used during the short courses offered

  3. The assembly language program design used in model DD80 multifunction microcomputer multichannel analyzer

    International Nuclear Information System (INIS)

    Wei Yiziang; Chen Ying; Zhao Xide

    1985-01-01

    This paper describes the structures, features, flowcharts and design considerations of assembly language program used in Model DD80 (FH1920) multifunction microcomputer multichannel analyzer. On the Model TRS-80 (I) microcomputer with DD80 multifunction interface this program can be used in spectrum data acquisition, spectrum live display and some spectrum data processing

  4. A thermophysical properties data base management system for reactor materials on the microcomputers

    International Nuclear Information System (INIS)

    Zhong Jianguo

    1995-01-01

    The thermophysical properties data base management system, named as TPSYS, is designed to store and manage the information on thermophysical properties of solid and liquid materials. Modular programmed, TPSYS is primarily written with dBASE-III PLUS language, C language is adopted in the plotting program and FORTRAN language is used for computing and data processing. In addition to the routine functions of DBMS, it has the module of executing the large calculation program MATPRO and the module of interfacing with the present DBMS THERSYST. Running on IBM-PC (386, 486) and compatible computers with the system of DOS 3.3, TPSYS is popular and user-friendly

  5. Machine Check-Out. Microcomputing Working Paper Series.

    Science.gov (United States)

    Drexel Univ., Philadelphia, PA. Microcomputing Program.

    During the academic year 1983-84, Drexel University instituted a new policy requiring all incoming students to have access to a microcomputer. The computer chosen to fulfill this requirement was the Macintosh from Apple Computer, Inc. Because Drexel University received one of the first large shipments of this new product, the degree to which these…

  6. Use of an Apple II plus microcomputer as a multichannel analyser for X-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Borowski, K.; Preiss, I.L.; LaBrecque, J.J.; Pauley, C.

    1983-01-01

    A description of two analogue to digital converters (ADCs), one a Wilkinson ADC and the other a successive approximation ADC, that are directly coupled to the bus of an Apple II plus microcomputer is presented. An outline of the available multichannel analyser (MCA) software for both systems is given. Finally, three applications of these systems are shown for real samples (industrial, geological and clinical)

  7. Use of an Apple II plus microcomputer as a multichannel analyser for X-ray fluorescence spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Borowski, K; Preiss, I L; LaBrecque, J J; Pauley, C [Instituto Venezolano de Investigaciones Cientificas, Caracas. Dept. de Fisica Atomica y Molecular

    1983-01-01

    A description of two analogue to digital converters (ADCs), one a Wilkinson ADC and the other a successive approximation ADC, that are directly coupled to the bus of an Apple II plus microcomputer is presented. An outline of the available multichannel analyser (MCA) software for both systems is given. Finally, three applications of these systems are shown for real samples (industrial, geological and clinical).

  8. The use of micro-computers in the simulation of ion beam optics

    International Nuclear Information System (INIS)

    Spaedtke, P.; Ivens, D.

    1989-01-01

    With computer simulation codes specific problems of the ion beam optics can be studied, which is useful in the design as in optimization of existing systems. Several such codes have been developed, unfortunately requiring substantial computer resources. Recent advances of mini- and micro-computers have now made it possible to develop simulation codes which can be run on these small computers also. In this paper, some of these codes will be presented and their computing time discussed. (author)

  9. A minimum operating system based on the SM5300.01 magnetic tape recorder for the Micro-8 computer

    International Nuclear Information System (INIS)

    Kartashov, S.V.

    1987-01-01

    An operating system (OS) for microcomputers based on INTEL-8080, 8085 microprocessors oriented to use a magnetic tape recorder is described. This system comprises a tape-recorder manager and a file structure organization system (nucleus of OS), a symbol text editor, a macroassembler, an interactive disasembler and a program of communication with an EC-computer. The OS makes it possible to develop, debug, store and exploit the program written in INTEL-8085 assembly language

  10. Microcomputer Activities Which Encourage the Reading-Writing Connection.

    Science.gov (United States)

    Balajthy, Ernest

    Many reading teachers, cognizant of the creative opportunities for skill development allowed by new reading-writing software, are choosing to use microcomputers in their classrooms full-time. Adventure story creation programs capitalize on reading-writing integration by allowing children, with appropriate assistance, to create their own…

  11. Continuous thickness control of extruded pipes with assistance of microcomputers

    International Nuclear Information System (INIS)

    Breil, J.

    1983-06-01

    Because of economic and quality securing reasons a constant wall thickness of extruded pipes in circumference and extrusion direction is an important production aim. Therefore a microcomputer controlled system was developed, which controls die centering with electric motors. The control of wall thickness distribution; was realized with two conceptions: a dead time subjected control with a rotating on line wall thickness measuring instrument and an adaptive control with sensors in the pipe die. With a PI-algorithm excentricities of 30% of the wall thickness could be controlled below a trigger level of 2% within three dead times. (orig.) [de

  12. Microcomputer network for technological equipment monitoring and control

    International Nuclear Information System (INIS)

    Segec, O.

    1990-01-01

    The properties and purpose are characterized of a microcomputer network developed for monitoring and controlling the nuclear power plant chemistry. In the development, emphasis was put on simplicity of the components, reliability, ease of operation and availability of the components on the domestic market. So far, these criteria are only met by the DIAMO L(S) system equipped with an MH 8080 (Z80) processor. Its assets include simplicity and ruggedness, owing to which it is well suited to heavy-duty performance, whereas its drawbacks comprise a narrow extent of addressable memory and absence of any supporting software. Until now, 5 types of automated stations have been developed and submitted for test operation at the Bohunice V-2 nuclear power plant. Virtually any personal computer can be attached to the network. The system can also be installed in conventional power plants as well as beyond the power generation field. (Z.M.)

  13. Desk-top microcomputer for lab-scale process control

    International Nuclear Information System (INIS)

    Overman, R.F.; Byrd, J.S.; Goosey, M.H.; Sand, R.J.

    1981-01-01

    A desk-top microcomputer was programmed to acquire the data from various process control sensors installed in a laboratory scale liquid-liquid extraction, pulse column facility. The parameters monitored included valve positions, gamma spectra, alpha radioactivity, temperature, pH, density, and flow rates. The program for the microcomputer is written in BASIC and requires about 31000 8-bit bytes of memory. All data is stored on floppy discs, and can be displayed or printed. Unexpected data values are brought to the process operator's attention via CRT display or print-out. The general organization of the program and a few subroutines unique to polling instruments are explained. Some of the data acquisition devices were designed and built at the Savannah River Laboratory. These include a pulse height analyzer, a data multiplexer, and a data acquisition instrument. A general description of the electronics design of these instruments is also given with emphasis placed on data formatting and bus addressing

  14. Air Compressor Pressure Control System Based On Gearshift Integral PID Controller

    OpenAIRE

    PAN Chunyue

    2017-01-01

    The application of gearshift integral PID controller to air compressor pressure control system is introduced, Its kernel is single chip microcomputer PIC16F877.The design of hardware and solfware are introduced too. Practical application shows that this system has many advantages.

  15. The PWI [plutonium waste incinerator] expert system: Real time, PC-based process analysis

    International Nuclear Information System (INIS)

    Brown, K.G.; Smith, F.G.

    1987-01-01

    A real time, microcomputer-based expert system is being developed for a prototype plutonium waste incinerator (PWI) process at Du Pont's Savannah River Laboratory. The expert system will diagnose instrumentation problems, assist operator training, serve as a repository for engineering knowledge about the process, and provide continuous operation and performance information. A set of necessary operational criteria was developed from process and engineering constraints; it was used to define hardware and software needs. The most important criterion is operating speed because the analysis operates in real time. TURBO PROLOG by Borland International was selected. The analysis system is divided into three sections: the user-system interface, the inference engine and rule base, and the files representing the blackboard information center

  16. "Hack" Is Not A Dirty Word--The Tenth Anniversary of Patron Access Microcomputer Centers in Libraries.

    Science.gov (United States)

    Dewey, Patrick R.

    1986-01-01

    The history of patron access microcomputers in libraries is described as carrying on a tradition that information and computer power should be shared. Questions that all types of libraries need to ask in planning microcomputer centers are considered and several model centers are described. (EM)

  17. Application of a portable microcomputer mental acuity battery for fitness-for-duty assessment in power plant operations

    International Nuclear Information System (INIS)

    Kennedy, R.S.; Turnage, J.T.; Lane, N.E.

    1988-01-01

    A need exists for assessment of fitness-for-duty in power plants. Several microcomputer-based mental acuity test batteries are under development for objective assessment of human performance over repeated measures. One of these, the Automated Performance Test System (APTS), has been shown to be sensitive to various environments and treatments and could prove useful for this purpose. Tests from these batteries should be studied during the naturally occurring stresses of power plant activity (e.g., shift work, sustained operations, sleep deprivation, stressful periods) in order to establish the effects of such issues on performance, and to provide insights and scientific data for the development of standards and regulations

  18. Development of a new signal processor for tetralateral position sensitive detector based on single-chip microcomputer

    International Nuclear Information System (INIS)

    Huang Meizhen; Shi Longzhao; Wang Yuxing; Ni Yi; Li Zhenqing; Ding Haifeng

    2006-01-01

    An inherently nonlinear relation between the output current of the tetralateral position sensitive detector (PSD) and the position of the incident light spot has been found theoretically. Based on single-chip microcomputer and the theoretical relation between output current and position, a new signal processor capable of correcting nonlinearity and reducing position measurement deviation of tetralateral PSD was developed. A tetralateral PSD (S1200, 13x13 mm 2 , Hamamatsu Photonics K.K.) was measured with the new signal processor, a linear relation between the output position of the PSD, and the incident position of the light spot was obtained. In the 60% range of a 13x13 mm 2 active area, the position nonlinearity (rms) was 0.15% and the position measurement deviation (rms) was ±20 μm. Compared with traditional analog signal processor, the new signal processor is of better compatibility, lower cost, higher precision, and easier to be interfaced

  19. A micro-computed tomographic evaluation of dentinal microcrack alterations during root canal preparation using single-file Ni-Ti systems.

    Science.gov (United States)

    Li, Mei-Lin; Liao, Wei-Li; Cai, Hua-Xiong

    2018-01-01

    The aim of the present study was to evaluate the length of dentinal microcracks observed prior to and following root canal preparation with different single-file nickel-titanium (Ni-Ti) systems using micro-computed tomography (micro-CT) analysis. A total of 80 mesial roots of mandibular first molars presenting with type II Vertucci canal configurations were scanned at an isotropic resolution of 7.4 µm. The samples were randomly assigned into four groups (n=20 per group) according to the system used for root canal preparation, including the WaveOne (WO), OneShape (OS), Reciproc (RE) and control groups. A second micro-CT scan was conducted after the root canals were prepared with size 25 instruments. Pre- and postoperative cross-section images of the roots (n=237,760) were then screened to identify the lengths of the microcracks. The results indicated that the microcrack lengths were notably increased following root canal preparation (Pfiles. Among the single-file Ni-Ti systems, WO and RE were not observed to cause notable microcracks, while the OS system resulted in evident microcracks.

  20. Getting Started with Microcomputers--A Practical Beginner's Guide.

    Science.gov (United States)

    Davies, Norman F.

    1985-01-01

    Discusses the results of a questionnaire sent to experts in the field of computer assisted language learning. Covers such topics as: 1) points to consider before buying a microcomputer; 2) recommended brands and peripheral equipment; 3) software; 4) utilizing programming languages; and 5) literature and contact organizations. (SED)

  1. MOVES: A knowledge-based system for maintenance planning for motor-operated valves

    International Nuclear Information System (INIS)

    Winter, M.

    1987-01-01

    Over the past several years, knowledge-based expert systems have emerged as an important part of the general research area known as artificial intelligence. This paper describes a cooperative effort between faculty members at Iowa State University and engineers at the Duane Arnold Energy Center [a 545-MW(electric) boiling water reactor operated by Iowa Electric Light and Power Company] to explore the development of an advisory system for valve maintenance planning. This knowledge-based program, known as Motor-Operated Valves Expert System (MOVES), has a data base that currently includes safety-related motor-operated valves (∼117 valves). Valve maintenance was selected as the subject for the expert system because of the importance of valves in nuclear plant and their impact of plant availability. MOVES is being developed using the microcomputer-(IBM compatible) based expert system tool INSIGHT2+. The authors have found that the project benefits both the university and the utility

  2. Storage and analysis of radioisotope scan data using a microcomputer

    Energy Technology Data Exchange (ETDEWEB)

    Crawshaw, I P; Diffey, B L [Dryburn Hospital, Durham (UK)

    1981-08-01

    A data storage system has been created for recording clinical radioisotope scan data on a microcomputer system, located and readily available for use in an imaging department. The input of patient data from the request cards and the results sheets is straightforward as menus and code numbers are used throughout a logical sequence of steps in the program. The questions fall into four categories; patient information, referring centre information, diagnosis and symptoms and results of the investigation. The main advantage of the analysis program is its flexibility in that it follows the same format as the input program and any combination of criteria required for analysis may be selected. The menus may readily be altered and the programs adapted for use in other hospital departments.

  3. Storage and analysis of radioisotope scan data using a microcomputer

    International Nuclear Information System (INIS)

    Crawshaw, I.P.; Diffey, B.L.

    1981-01-01

    A data storage system has been created for recording clinical radioisotope scan data on a microcomputer system, located and readily available for use in an imaging department. The input of patient data from the request cards and the results sheets is straightforward as menus and code numbers are used throughout a logical sequence of steps in the program. The questions fall into four categories; patient information, referring centre information, diagnosis and symptoms and results of the investigation. The main advantage of the analysis program is its flexibility in that it follows the same format as the input program and any combination of criteria required for analysis may be selected. The menus may readily be altered and the programs adapted for use in other hospital departments. (U.K.)

  4. Optimizing a micro-computed tomography-based surrogate measurement of bone-implant contact.

    Science.gov (United States)

    Meagher, Matthew J; Parwani, Rachna N; Virdi, Amarjit S; Sumner, Dale R

    2018-03-01

    Histology and backscatter scanning electron microscopy (bSEM) are the current gold standard methods for quantifying bone-implant contact (BIC), but are inherently destructive. Microcomputed tomography (μCT) is a non-destructive alternative, but attempts to validate μCT-based assessment of BIC in animal models have produced conflicting results. We previously showed in a rat model using a 1.5 mm diameter titanium implant that the extent of the metal-induced artefact precluded accurate measurement of bone sufficiently close to the interface to assess BIC. Recently introduced commercial laboratory μCT scanners have smaller voxels and improved imaging capabilities, possibly overcoming this limitation. The goals of the present study were to establish an approach for optimizing μCT imaging parameters and to validate μCT-based assessment of BIC. In an empirical parametric study using a 1.5 mm diameter titanium implant, we determined 90 kVp, 88 µA, 1.5 μm isotropic voxel size, 1600 projections/180°, and 750 ms integration time to be optimal. Using specimens from an in vivo rat experiment, we found significant correlations between bSEM and μCT for BIC with the manufacturer's automated analysis routine (r = 0.716, p = 0.003) or a line-intercept method (r = 0.797, p = 0.010). Thus, this newer generation scanner's improved imaging capability reduced the extent of the metal-induced artefact zone enough to permit assessment of BIC. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:979-986, 2018. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  5. Contrast enhanced micro-computed tomography resolves the 3-dimensional morphology of the cardiac conduction system in mammalian hearts.

    Directory of Open Access Journals (Sweden)

    Robert S Stephenson

    Full Text Available The general anatomy of the cardiac conduction system (CCS has been known for 100 years, but its complex and irregular three-dimensional (3D geometry is not so well understood. This is largely because the conducting tissue is not distinct from the surrounding tissue by dissection. The best descriptions of its anatomy come from studies based on serial sectioning of samples taken from the appropriate areas of the heart. Low X-ray attenuation has formerly ruled out micro-computed tomography (micro-CT as a modality to resolve internal structures of soft tissue, but incorporation of iodine, which has a high molecular weight, into those tissues enhances the differential attenuation of X-rays and allows visualisation of fine detail in embryos and skeletal muscle. Here, with the use of a iodine based contrast agent (I(2KI, we present contrast enhanced micro-CT images of cardiac tissue from rat and rabbit in which the three major subdivisions of the CCS can be differentiated from the surrounding contractile myocardium and visualised in 3D. Structures identified include the sinoatrial node (SAN and the atrioventricular conduction axis: the penetrating bundle, His bundle, the bundle branches and the Purkinje network. Although the current findings are consistent with existing anatomical representations, the representations shown here offer superior resolution and are the first 3D representations of the CCS within a single intact mammalian heart.

  6. DEPDOSE: An interactive, microcomputer based program to calculate doses from exposure to radionuclides deposited on the ground

    International Nuclear Information System (INIS)

    Beres, D.A.; Hull, A.P.

    1991-12-01

    DEPDOSE is an interactive, menu driven, microcomputer based program designed to rapidly calculate committed dose from radionuclides deposited on the ground. The program is designed to require little or no computer expertise on the part of the user. The program consisting of a dose calculation section and a library maintenance section. These selections are available to the user from the main menu. The dose calculation section provides the user with the ability to calculate committed doses, determine the decay time needed to reach a particular dose, cross compare deposition data from separate locations, and approximate a committed dose based on a measured exposure rate. The library maintenance section allows the user to review and update dose modifier data as well as to build and maintain libraries of radionuclide data, dose conversion factors, and default deposition data. The program is structured to provide the user easy access for reviewing data prior to running the calculation. Deposition data can either be entered by the user or imported from other databases. Results can either be displayed on the screen or sent to the printer

  7. An 'ADC-Memory' system based on a new principle in data access

    International Nuclear Information System (INIS)

    Pan Dajing; Wu Yongqing; Wang Shibo

    1990-01-01

    A new kind of 'ADC-Memory' (ADC-M) with real time correction of counting loss in dead time is now used in a multiuser data acquisition and processing system based on DUAL/68000 microcomputer. In data access, it replaces the 'DMA + 1' in classical MCA with the new method 'DMA + N', where N is weight factor of correction. The new method is based on the principle of virtual pulse generator. This method is superior to the correction by the software because the correction needn't take the computer time. Thus, this ADC-M can be used in the counting of high rate pulses

  8. Attenuation Drift in the Micro-Computed Tomography System at LLNL

    Energy Technology Data Exchange (ETDEWEB)

    Dooraghi, Alex A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Brown, William [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Seetho, Isaac [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Kallman, Jeff [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Lennox, Kristin [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Glascoe, Lee [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2016-01-12

    The maximum allowable level of drift in the linear attenuation coefficients (μ) for a Lawrence Livermore National Laboratory (LLNL) micro-computed tomography (MCT) system was determined to be 0.1%. After ~100 scans were acquired during the period of November 2014 to March 2015, the drift in μ for a set of six reference materials reached or exceeded 0.1%. Two strategies have been identified to account for or correct the drift. First, normalizing the 160 kV and 100 kV μ data by the μ of water at the corresponding energy, in contrast to conducting normalization at the 160 kV energy only, significantly compensates for measurement drift. Even after the modified normalization, μ of polytetrafluoroethylene (PTFE) increases linearly with scan number at an average rate of 0.00147% per scan. This is consistent with PTFE radiation damage documented in the literature. The second strategy suggested is the replacement of the PTFE reference with fluorinated ethylene propylene (FEP), which has the same effective atomic number (Ze) and electron density (ρe) as PTFE, but is 10 times more radiation resistant. This is important as effective atomic number and electron density are key parameters in analysis. The presence of a material with properties such as PTFE, when taken together with the remaining references, allows for a broad range of the (Ze, ρe) feature space to be used in analysis. While FEP is documented as 10 times more radiation resistant, testing will be necessary to assess how often, if necessary, FEP will need to be replaced. As radiation damage to references has been observed, it will be necessary to monitor all reference materials for radiation damage to ensure consistent x-ray characteristics of the references.

  9. Design of indoor temperature and humidity detection system based on single chip microcomputer

    Science.gov (United States)

    Fu, Xiuwei; Fu, Li; Ma, Tianhui

    2018-03-01

    The indoor temperature and humidity detection system based on STC15F2K60S2 is designed in this paper. The temperature and humidity sensor DHT22 to monitor the indoor temperature and humidity are used, and the temperature and humidity data to the user's handheld device are wirelessly transmitted, when the temperature reaches or exceeds the user set the temperature alarm value, and the system sound and light alarm, to remind the user.

  10. Air Compressor Pressure Control System Based On Gearshift Integral PID Controller

    Directory of Open Access Journals (Sweden)

    PAN Chunyue

    2017-01-01

    Full Text Available The application of gearshift integral PID controller to air compressor pressure control system is introduced, Its kernel is single chip microcomputer PIC16F877.The design of hardware and solfware are introduced too. Practical application shows that this system has many advantages.

  11. Learning Together: Micro-Computers in Crosby, Texas, Schools.

    Science.gov (United States)

    McNeil, Linda M.

    The Crosby Independent School District near Houston, Texas, planned to introduce microcomputer instruction to its nearly 3,000 students in slow stages that had teachers and students learning at the same time. The initial impetus for computers came from an administrator who found useful information at a Regional Service Center of the State…

  12. Knowledge based expert system approach to instrumentation selection (INSEL

    Directory of Open Access Journals (Sweden)

    S. Barai

    2004-08-01

    Full Text Available The selection of appropriate instrumentation for any structural measurement of civil engineering structure is a complex task. Recent developments in Artificial Intelligence (AI can help in an organized use of experiential knowledge available on instrumentation for laboratory and in-situ measurement. Usually, the instrumentation decision is based on the experience and judgment of experimentalists. The heuristic knowledge available for different types of measurement is domain dependent and the information is scattered in varied knowledge sources. The knowledge engineering techniques can help in capturing the experiential knowledge. This paper demonstrates a prototype knowledge based system for INstrument SELection (INSEL assistant where the experiential knowledge for various structural domains can be captured and utilized for making instrumentation decision. In particular, this Knowledge Based Expert System (KBES encodes the heuristics on measurement and demonstrates the instrument selection process with reference to steel bridges. INSEL runs on a microcomputer and uses an INSIGHT 2+ environment.

  13. 80537 based distance relay

    DEFF Research Database (Denmark)

    Pedersen, Knud Ole Helgesen

    1999-01-01

    A method for implementing a digital distance relay in the power system is described.Instructions are given on how to program this relay on a 80537 based microcomputer system.The problem is used as a practical case study in the course 53113: Micocomputer applications in the power system.The relay...

  14. Quantification of lung fibrosis and emphysema in mice using automated micro-computed tomography.

    Directory of Open Access Journals (Sweden)

    Ellen De Langhe

    Full Text Available BACKGROUND: In vivo high-resolution micro-computed tomography allows for longitudinal image-based measurements in animal models of lung disease. The combination of repetitive high resolution imaging with fully automated quantitative image analysis in mouse models of lung fibrosis lung benefits preclinical research. This study aimed to develop and validate such an automated micro-computed tomography analysis algorithm for quantification of aerated lung volume in mice; an indicator of pulmonary fibrosis and emphysema severity. METHODOLOGY: Mice received an intratracheal instillation of bleomycin (n = 8, elastase (0.25 U elastase n = 9, 0.5 U elastase n = 8 or saline control (n = 6 for fibrosis, n = 5 for emphysema. A subset of mice was scanned without intervention, to evaluate potential radiation-induced toxicity (n = 4. Some bleomycin-instilled mice were treated with imatinib for proof of concept (n = 8. Mice were scanned weekly, until four weeks after induction, when they underwent pulmonary function testing, lung histology and collagen quantification. Aerated lung volumes were calculated with our automated algorithm. PRINCIPAL FINDINGS: Our automated image-based aerated lung volume quantification method is reproducible with low intra-subject variability. Bleomycin-treated mice had significantly lower scan-derived aerated lung volumes, compared to controls. Aerated lung volume correlated with the histopathological fibrosis score and total lung collagen content. Inversely, a dose-dependent increase in lung volume was observed in elastase-treated mice. Serial scanning of individual mice is feasible and visualized dynamic disease progression. No radiation-induced toxicity was observed. Three-dimensional images provided critical topographical information. CONCLUSIONS: We report on a high resolution in vivo micro-computed tomography image analysis algorithm that runs fully automated and allows quantification of aerated lung volume in mice. This

  15. THE ROLE OF THE MICROCOMPUTER IN THE DEMISE OF WESTERN CIVILIZATION

    Energy Technology Data Exchange (ETDEWEB)

    Stevens, David

    1979-02-01

    Every revolutionary: new technology has been accompanied by a host of Cassandras prophesying the end of the world as we know it. Unlike Cassandra, heretofore they have all been wrong. The microcomputer has come into its own as a revolutioary new technology, and the new generation of Cassandras is beginning to appear. They, too, for the most part are wrong, but their error is not in their conclusion--for the microcomputer will bring about the end of Western Civilization--but in their conentration on technological consequences. It is rather a social consequence, the willful dis-integiation of society, which will be the motivating force. But Cassandra's tragedy was that no-one listened to her.

  16. The I-V Measurement System for Solar Cells Based on MCU

    International Nuclear Information System (INIS)

    Chen Fengxiang; Ai Yu; Wang Jiafu; Wang Lisheng

    2011-01-01

    In this paper, an I-V measurement system for solar cells based on Single-chip Microcomputer (MCU) is presented. According to the test principles of solar cells, this measurement system mainly comprises of two parts-data collecting, data processing and displaying. The MCU mainly used as to acquire data, then the collecting results is sent to the computer by serial port. The I-V measurement results of our test system are shown in the human-computer interaction interface based on our hardware circuit. By comparing the test results of our I-V tester and the results of other commercial I-V tester, we found errors for most parameters are less than 5%, which shows our I-V test result is reliable. Because the MCU can be applied in many fields, this I-V measurement system offers a simple prototype for portable I-V tester for solar cells.

  17. The I-V Measurement System for Solar Cells Based on MCU

    Energy Technology Data Exchange (ETDEWEB)

    Chen Fengxiang; Ai Yu; Wang Jiafu; Wang Lisheng, E-mail: phonixchen79@yahoo.com.cn [Department of physics science and technology, Wuhan University of Technology, Wuhan city, Hubei Province, 430070 (China)

    2011-02-01

    In this paper, an I-V measurement system for solar cells based on Single-chip Microcomputer (MCU) is presented. According to the test principles of solar cells, this measurement system mainly comprises of two parts-data collecting, data processing and displaying. The MCU mainly used as to acquire data, then the collecting results is sent to the computer by serial port. The I-V measurement results of our test system are shown in the human-computer interaction interface based on our hardware circuit. By comparing the test results of our I-V tester and the results of other commercial I-V tester, we found errors for most parameters are less than 5%, which shows our I-V test result is reliable. Because the MCU can be applied in many fields, this I-V measurement system offers a simple prototype for portable I-V tester for solar cells.

  18. Design of Racing Electric Control System Based on AVR SCM

    Directory of Open Access Journals (Sweden)

    Shuang WAN

    2014-10-01

    Full Text Available A racing car’s instrument system, signal system and monitoring system were designed based on the rules of the competition (FSAE, Formula SAE. The main components of the instrument system were selected by comparing the advantages and disadvantages of various instrument systems. And the circuit diagram and PCB diagram of the instrument system was drawn by Altium Designer. Then, the instrument system with Single Chip Microcomputer (SCM as the main body was set up according to the circuit diagram. Besides, programs were written according to the function of instrument system. Finally, the instrument system was debugged. In the aspect of the design of signal system and monitoring system, the circuit diagram of signal system and signal system were drawn according to the racing design requirements and rules. Currently, the instrument system has been successfully debugged. And the design of circuit diagram of signal system and monitoring system has been completed.

  19. Model H-90A gamma-ray spectrometer with microcomputer

    International Nuclear Information System (INIS)

    Zhang Biao; Dong Chen; Zhao Zhiming

    1994-11-01

    Model H-90A is a 4-channel differential Gamma-ray spectrometer with microcomputer. It consists of a console and NaI(TL) crystal detector with a diameter of φ75 mm x 75 mm. The instrument has excellent performance such as automatic spectrum stabilization, automatic regular timing measurement and automatic calculation of uranium, thorium and potassium contents and their ratios. Original data can be manually and automatically stored. The instrument is provided with shut down supply protective device, reading out can be repeated or be further processed through RS-232 interface output in the case of connection with computer. The working command is inputted by 'soft key' and performed by slice microcomputer automatically through software. It can be used not only in radioactive geological mapping, geochemical research and rapid field assay of radioactive elements in mineral and rock samples, but also for exploration and reconnaissance survey for uranium, thorium, potassium and seeking gold, as well as environmental monitoring

  20. Development of an above-knee prosthesis equipped with a microcomputer-controlled knee joint: first test results.

    Science.gov (United States)

    Aeyels, B; Peeraer, L; Vander Sloten, J; Van der Perre, G

    1992-05-01

    The shortcomings of conventional above-knee prostheses are due to their lack of adaptive control. Implementation of a microcomputer controlling the knee joint in a passive way has been suggested to enhance the patient's gait comfort, safety and cosmesis. This approach was used in the design of a new prosthetic system for the above-knee amputee, and tested on one patient. The knee joint of a conventional, modular prosthesis was replaced by a knee joint mechanism, equipped with a controllable brake on the knee joint axis. Sensors and a microcomputer were added, keeping the system self-contained. The modularity of the design permits the use of an alternative, external, PC-based control unit, emulating the self-contained one, and offering extended data monitoring and storage facilities. For both units an operating environment was written, including sensor/actuator interfacing and the implementation of a real-time interrupt, executing the control algorithm. A double finite state approach was used in the design of the control algorithm. On a higher level, the mode identification algorithm reveals the patient's intent. Within a specific mode (lower level), the relevant mode control algorithm looks for the current phase within the gait cycle. Within a particular phase, a specific simple control action with the brake replaces normal knee muscle activity. Tests were carried out with one prosthetic patient using a basic control algorithm for level walking, allowing controlled knee flexion during stance phase. The technical feasibility of such a concept is illustrated by the test results, even though only flexion during early stance phase was controlled during the trials.(ABSTRACT TRUNCATED AT 250 WORDS)

  1. A multifunctional data acquisition and processing system based on microcomputer

    International Nuclear Information System (INIS)

    Chen Huaide; Pan Dajing; Zhu Cuiqin

    1988-01-01

    Introduced herein is a multifunctional MCA-computer system which can operate as a foreground and a background with capabilities of high resolution in γ-ray spectrum analysis, multiplex multi-scale, multi-scale, and the display system with resolution being high up to 8192 points. The MCA has 8192 channels with 20 bits and 8k buffer memory. Firstly, the acquisition data is stored into the buffer memory and then transformed into computer for processing. The system software consists of the management software, spectrum processing and multiplex multi-scale measurement software. The block diagram of the system, the specifications and testing results are given

  2. Microcomputer Network for Computerized Adaptive Testing (CAT)

    Science.gov (United States)

    1984-03-01

    PRDC TR 84-33 \\Q.�d-33- \\ MICROCOMPUTER NETWOJlt FOR COMPUTERIZED ADAPTIVE TESTING ( CAT ) Baldwin Quan Thomas A . Park Gary Sandahl John H...ACCEIIION NO NPRDC TR 84-33 4. TITLE (-d Sul>tlllo) MICROCOMP UTER NETWORK FOR COMPUTERIZED ADA PTIVE TESTING ( CAT ) 1. Q B. uan T. A . Park...adaptive testing ( CAT ) Bayesian sequential testing 20. ABSTitACT (Continuo on ro•••• aide II noco .. _, _., ld-tlly ,.,. t.loclt _._.) DO Computerized

  3. Multiprogrammation fast branch driver for microcomputer MICRAL

    International Nuclear Information System (INIS)

    Kaiser, Josef; Lacroix, Jean.

    1975-01-01

    This branch driver allows in association with the FIFO memories of the microcomputer Micral, very fast exchanges with the 7 crates of a CAMAC branch. A CAMAC programm (command, test, read, write) is loaded in the 1K FIFO buffer of the Micral before execution time and executed in sequence at a rate of 1,5μs per CAMAC command. After programm execution, data may be transferred directly on a magnetic tape [fr

  4. Microcomputers in the Classroom: Trojan Horse or Teacher's Pet?

    Science.gov (United States)

    Olson, John K.

    Arguing that curriculum developers need to seek a better understanding of existing classroom orders before advising reform through new technology, this paper presents a review of research on the effects of microcomputers on the stabilities of classroom practice and describes a pilot study currently underway at Queens University in Ontario to…

  5. Page: a program for gamma spectra analysis in PC microcomputers

    International Nuclear Information System (INIS)

    Goncalves, M.A.; Yamaura, M.; Costa, G.J.C.; Carvalho, E.I. de; Matsuda, H.T.; Araujo, B.F. de.

    1991-04-01

    PAGE is a software package, written in BASIC language, to perform gamma spectra analysis. It was developed to be used in a high-purity intrinsic germanium detector-multichannel analyser-PC microcomputer system. The analysis program of PAGE package accomplishes functions as follows: peak location; gamma nuclides identification; activity determination. Standard nuclides sources were used to calibrate the system. To perform the efficiency x energy calibration a logarithmic fit was applied. Analysis of nuclides with overlapping peaks is allowed by PAGE program. PAGE has additional auxiliary programs for: building and list of isotopic nuclear data libraries; data acquisition from multichannel analyser; spectrum display with automatic area and FWHM determinations. This software is to be applied in analytical process control where time response is a very important parameter. PAGE takes ca. 1.5 minutes to analyse a complex spectrum from a 4096 channels MCA. (author)

  6. Study on irradiation effects of nucleus electromagnetic pulse on single chip computer system

    International Nuclear Information System (INIS)

    Hou Minsheng; Liu Shanghe; Wang Shuping

    2001-01-01

    Intense electromagnetic pulse, namely nucleus electromagnetic pulse (NEMP), lightning electromagnetic pulse (LEMP) and high power microwave (HPM), can disturb and destroy the single chip computer system. To study this issue, the authors made irradiation experiments by NEMPs generated by gigahertz transversal electromagnetic (GTEM) Cell. The experiments show that shutdown, restarting, communication errors of the single chip microcomputer system would occur when it was irradiated by the NEMPs. Based on the experiments, the cause on the effects on the single chip microcomputer system is discussed

  7. Microcomputers in Vocational Home Economics Classrooms in USD #512.

    Science.gov (United States)

    Shawnee Mission Public Schools, KS.

    A project was conducted to identify software suitable for use in home economics classes and to train home economics teachers to use that software with an Apple II Plus microcomputer. During the project, home economics software was identified, evaluated, and catalogued. Teaching strategies were adapted to include using the computer in the…

  8. Microcomputers in Schools as a Teaching and Learning Aid.

    Science.gov (United States)

    Trotman-Dickenson, D. I.

    1986-01-01

    Presents the findings of a survey of comprehensive and independent schools' use of microcomputers as teaching and learning aids in economics. Results suggest that use is wide spread but not intensive. Teachers allocate few hours to computer programs per year, have difficulty finding suitable software, and fail to encourage use by girls. (JDH)

  9. System program for MICRO-CAMAC terminal system

    International Nuclear Information System (INIS)

    Sasajima, Yoji; Yamada, Takayuki; Yagi, Hideyuki; Ishiguro, Misako

    1979-08-01

    A JAERI on-line network system was developed and exists for on-line data processing of nuclear instrumentation. As terminal systems for the network system, the one with a Micro -8 micro-computer is used. By modifying the control program for Micro-8 terminal system, a system program has been developed for a MICRO-CAMAC terminal system, which is controlled by a micro-computer framed within the CAMAC Crate Controller. In this report are described software specifications of the MICRO -CAMAC terminal system and its operation method. (author)

  10. Independent multi-channel analyzer with the color display and microcomputer in the CAMAC standard

    International Nuclear Information System (INIS)

    Gyunter, Z.; Elizarov, O.I.; Zhukov, G.P.; Mikhaehlis, B.; Shul'tts, K.Kh.

    1983-01-01

    An independent multi-channel time-of-flight analyzer developed for a spectrometer of polarised neutrons and used in experiments with the IBR-2 pulse reactor is described. Different cyclic modes of measuring are realized in the analyzer, 4 kwords of analyzer momory being assigned for each mode. The spectra are displayed on a colour screen during measurements. Simultaneous displaying of up to 8 spectra is possible. A microcomputer transfers the spectra from the buffer analyzer memory to the microcomputer memory. The accumulated information is transferred to the PDP-11/70 central computer

  11. Microcomputer Calculation of Thermodynamic Properties from Molecular Parameters of Gases.

    Science.gov (United States)

    Venugopalan, Mundiyath

    1990-01-01

    Described in this article is a problem-solving activity which integrates the application of microcomputers with the learning of physical chemistry. Students use the program with spectroscopic data to calculate the thermodynamic properties and compare them with the values from the thermochemical tables. (Author/KR)

  12. Computer based C and I systems in Indian PHWRs

    International Nuclear Information System (INIS)

    Govindarajan, G.; Sharma, M.P.

    1997-01-01

    Benefits of programmable digital technology have been well recognized and employment of computer based systems in Indian PHWRs has evolved in a phased manner, keeping in view the regulatory requirements for their use. In the initial phase some operator information functions and control of on-power fuel handling system were implemented and then some systems performing control and safety functions have been employed. The availability of powerful microcomputer hardware at reasonable cost and indigenous capability in design and execution has encouraged wider use of digital technology in the nuclear power programme. To achieve the desired level of quality and reliability, the hardware modules for the implementation of these systems in the plants under construction, have been standardized and methodology for software verification and validation has been evolved. A large number of C and I functions including those for equipment diagnostics are being implemented. The paper describes the various applications of computers in Indian NPPs and their current status of implementation. (author)

  13. A memory efficient user interface for CLIPS micro-computer applications

    Science.gov (United States)

    Sterle, Mark E.; Mayer, Richard J.; Jordan, Janice A.; Brodale, Howard N.; Lin, Min-Jin

    1990-01-01

    The goal of the Integrated Southern Pine Beetle Expert System (ISPBEX) is to provide expert level knowledge concerning treatment advice that is convenient and easy to use for Forest Service personnel. ISPBEX was developed in CLIPS and delivered on an IBM PC AT class micro-computer, operating with an MS/DOS operating system. This restricted the size of the run time system to 640K. In order to provide a robust expert system, with on-line explanation, help, and alternative actions menus, as well as features that allow the user to back up or execute 'what if' scenarios, a memory efficient menuing system was developed to interface with the CLIPS programs. By robust, we mean an expert system that (1) is user friendly, (2) provides reasonable solutions for a wide variety of domain specific problems, (3) explains why some solutions were suggested but others were not, and (4) provides technical information relating to the problem solution. Several advantages were gained by using this type of user interface (UI). First, by storing the menus on the hard disk (instead of main memory) during program execution, a more robust system could be implemented. Second, since the menus were built rapidly, development time was reduced. Third, the user may try a new scenario by backing up to any of the input screens and revising segments of the original input without having to retype all the information. And fourth, asserting facts from the menus provided for a dynamic and flexible fact base. This UI technology has been applied successfully in expert systems applications in forest management, agriculture, and manufacturing. This paper discusses the architecture of the UI system, human factors considerations, and the menu syntax design.

  14. Intelligent Home Control System Based on Single Chip Microcomputer

    Science.gov (United States)

    Yang, Libo

    2017-12-01

    Intelligent home as a way to achieve the realization of the family information has become an important part of the development of social information, Internet of Things because of its huge application prospects, will be smart home industry in the development process of a more realistic breakthrough in the smart home industry development has great significance. This article is based on easy to implement, easy to operate, close to the use of the design concept, the use of STC89C52 microcontroller as the control core for the control terminal, and including infrared remote control, buttons, Web interface, including multiple control sources to control household appliances. The second chapter of this paper describes the design of the hardware and software part of the specific implementation, the fifth chapter is based on the design of a good function to build a specific example of the environment.

  15. Gamma camera image acquisition, display, and processing with the personal microcomputer

    International Nuclear Information System (INIS)

    Lear, J.L.; Pratt, J.P.; Roberts, D.R.; Johnson, T.; Feyerabend, A.

    1990-01-01

    The authors evaluated the potential of a microcomputer for direct acquisition, display, and processing of gamma camera images. Boards for analog-to-digital conversion and image zooming were designed, constructed, and interfaced to the Macintosh II (Apple Computer, Cupertino, Calif). Software was written for processing of single, gated, and time series images. The system was connected to gamma cameras, and its performance was compared with that of dedicated nuclear medicine computers. Data could be acquired from gamma cameras at rates exceeding 200,000 counts per second, with spatial resolution exceeding intrinsic camera resolution. Clinical analysis could be rapidly performed. This system performed better than most dedicated nuclear medicine computers with respect to speed of data acquisition and spatial resolution of images while maintaining full compatibility with the standard image display, hard-copy, and networking formats. It could replace such dedicated systems in the near future as software is refined

  16. Data acquisition and control system for the IPNS time-of-flight neutron scattering instruments

    International Nuclear Information System (INIS)

    Daly, R.T.; Haumann, J.R.; Kraimer, M.R.; Lenkszus, F.R.; Lidinsky, W.P.; Morgan, C.B.; Rutledge, L.L.; Rynes, P.E.; Tippie, J.W.

    1979-01-01

    The Argonne Intense Pulsed Neutron System (IPNS-I) presently under construction at Argonne National Laboratory will include a number of neutron scattering instruments. This study investigates the data acquisition requirements of these instruments and proposes three alternative multiprocessor systems which will satisfy these requirements. All proposals are star configurations with a super-mini as the central node or HOST. The first proposal is based on front-ends composed of two or more 16-bit microcomputers, the second proposal is based on front ends consisting of a combination of a mini and microcomputers, and the third is based on a minicomputer with an intelligent CAMAC controller

  17. The VPI program package adapted to microcomputer for in-core fuel-management

    International Nuclear Information System (INIS)

    Sumitra, T.; Bhongsuwan, T.

    1988-01-01

    The neutron shielding analysis and design program was developed for microcomputer, by modifying the SABINE-3 shielding code which was written for mainframe computers. The program is based on removal-diffusion method and was modified from the SABINE-3 code. The program could be used to calculate shielding for nuclear reactors and neutron source. The accuracy of the program was tested by determining the neutron and gamma dose rate of a test case of Cf-252 source. The results were nearly identical with those obtained from original SABINE-3 which was computed on PRIME 9750 super minicomputer. Computing time was about 65 minutes

  18. Bringing the Microcomputer into the Junior High: A Success Story from Florida.

    Science.gov (United States)

    Miller, Benjamin S.

    1982-01-01

    Describes the introduction of an Apple II microcomputer into Miami Lakes (Florida) Junior High School and its success in generating enthusiasm among teachers, students, parents, and the community. (Author/RW)

  19. Periodic precipitation a microcomputer analysis of transport and reaction processes in diffusion media, with software development

    CERN Document Server

    Henisch, H K

    1991-01-01

    Containing illustrations, worked examples, graphs and tables, this book deals with periodic precipitation (also known as Liesegang Ring formation) in terms of mathematical models and their logical consequences, and is entirely concerned with microcomputer analysis and software development. Three distinctive periodic precipitation mechanisms are included: binary diffusion-reaction; solubility modulation, and competitive particle growth. The book provides didactic illustrations of a valuable investigational procedure, in the form of hypothetical experimentation by microcomputer. The development

  20. Microcomputer simulation model for facility performance assessment: a case study of nuclear spent fuel handling facility operations

    International Nuclear Information System (INIS)

    Chockie, A.D.; Hostick, C.J.; Otis, P.T.

    1985-10-01

    A microcomputer based simulation model was recently developed at the Pacific Northwest Laboratory (PNL) to assist in the evaluation of design alternatives for a proposed facility to receive, consolidate and store nuclear spent fuel from US commercial power plants. Previous performance assessments were limited to deterministic calculations and Gantt chart representations of the facility operations. To insure that the design of the facility will be adequate to meet the specified throughput requirements, the simulation model was used to analyze such factors as material flow, equipment capability and the interface between the MRS facility and the nuclear waste transportation system. The simulation analysis model was based on commercially available software and application programs designed to represent the MRS waste handling facility operations. The results of the evaluation were used by the design review team at PNL to identify areas where design modifications should be considered. 4 figs

  1. Independent working place on the base of the DVK-2M computer and UNO-4096 analyzer

    International Nuclear Information System (INIS)

    Zajtsev, M.Yu.; Balandin, A.F.

    1987-01-01

    Independent working place on the base of the DVK-2M microcomputer and UNO-4096-90 analyzer, designated for investigations of the field of reactor and protection physics is described. Two ways of the analyzer connection with the DVK-2M microcomputer are suggested : by means of CAMAC system or direct connection of UNO-analyzer with the DVK-2M processor

  2. The microcomputer scientific software series 2: general linear model--regression.

    Science.gov (United States)

    Harold M. Rauscher

    1983-01-01

    The general linear model regression (GLMR) program provides the microcomputer user with a sophisticated regression analysis capability. The output provides a regression ANOVA table, estimators of the regression model coefficients, their confidence intervals, confidence intervals around the predicted Y-values, residuals for plotting, a check for multicollinearity, a...

  3. Switching from computer to microcomputer architecture education

    Science.gov (United States)

    Bolanakis, Dimosthenis E.; Kotsis, Konstantinos T.; Laopoulos, Theodore

    2010-03-01

    In the last decades, the technological and scientific evolution of the computing discipline has been widely affecting research in software engineering education, which nowadays advocates more enlightened and liberal ideas. This article reviews cross-disciplinary research on a computer architecture class in consideration of its switching to microcomputer architecture. The authors present their strategies towards a successful crossing of boundaries between engineering disciplines. This communication aims at providing a different aspect on professional courses that are, nowadays, addressed at the expense of traditional courses.

  4. A computerised out-patient medical records programme based on the Summary Time-Oriented Record (STOR) System.

    Science.gov (United States)

    Cheong, P Y; Goh, L G; Ong, R; Wong, P K

    1992-12-01

    Advances in microcomputer hardware and software technology have made computerised outpatient medical records practical. We have developed a programme based on the Summary Time-Oriented Record (STOR) system which complements existing paper-based record keeping. The elements of the Problem Oriented Medical Record (POMR) System are displayed in two windows within one screen, namely, the SOAP (Subjective information, Objective information, Assessments and Plans) elements in the Reason For Encounter (RFE) window and the problem list with outcomes in the Problem List (PL) window. Context sensitive child windows display details of plans of management in the RFE window and clinical notes in the PL window. The benefits of such innovations to clinical decision making and practice based research and its medico-legal implications are discussed.

  5. Practical application of Integrated National Energy Planning (INEP) using microcomputers

    International Nuclear Information System (INIS)

    Munasinghe, M.

    1989-01-01

    The paper describes the use of a practical microcomputer-based, hierarchical modelling framework for Integrated National Energy Planning (INEP), and policy analysis. The rationale for the concept and the development of the methodology are traced, following the energy crises of the 1970s. Details of the INEP process, which includes analysis at three hierarchical levels (the energy-microeconomic, energy sector and energy subsector) are given. A description of the various models, the scenarios and assumptions used in the analysis, as well as the linkages and interactions, is provided. The Sri Lanka energy situation is summarized, and the principal energy issues and options derived from the modelling are used to synthesize a national energy strategy. (author). 11 refs, 8 figs, 11 tabs

  6. The dental cavities of equine cheek teeth: three-dimensional reconstructions based on high resolution micro-computed tomography

    Directory of Open Access Journals (Sweden)

    Kopke Susan

    2012-09-01

    Full Text Available Abstract Background Recent studies reported on the very complex morphology of the pulp system in equine cheek teeth. The continuous production of secondary dentine leads to distinct age-related changes of the endodontic cavity. Detailed anatomical knowledge of the dental cavities in all ages is required to explain the aetiopathology of typical equine endodontic diseases. Furthermore, data on mandibular and maxillary pulp systems is in high demand to provide a basis for the development of endodontic therapies. However, until now examination of the pulp cavity has been based on either sectioned teeth or clinical computed tomography. More precise results were expected by using micro-computed tomography with a resolution of about 0.1 mm and three-dimensional reconstructions based on previous greyscale analyses and histological verification. The aim of the present study was to describe the physiological configurations of the pulp system within a wide spectrum of tooth ages. Results Maxillary teeth: All morphological constituents of the endodontic cavity were present in teeth between 4 and 16 years: Triadan 06s displayed six pulp horns and five root canals, Triadan 07-10s five pulp horns and four root canals and Triadan 11s seven pulp horns and four to six root canals. A common pulp chamber was most frequent in teeth ≤5 years, but was found even in a tooth of 9 years. A large variety of pulp configurations was observed within 2.5 and 16 years post eruption, but most commonly a separation into mesial and distal pulp compartments was seen. Maxillary cheek teeth showed up to four separate pulp compartments but the frequency of two, three and four pulp compartments was not related to tooth age (P > 0.05. In Triadan 06s, pulp horn 6 was always connected to pulp horns 1 and 3 and root canal I. In Triadan 11s, pulp horns 7 and 8 were present in variable constitutions. Mandibular teeth: A common pulp chamber was present in teeth up to 15 years, but most

  7. Extending the Online Public Access Catalog into the Microcomputer Environment.

    Science.gov (United States)

    Sutton, Brett

    1990-01-01

    Describes PCBIS, a database program for MS-DOS microcomputers that features a utility for automatically converting online public access catalog search results stored as text files into structured database files that can be searched, sorted, edited, and printed. Topics covered include the general features of the program, record structure, record…

  8. Influence of Heat Treatment of Nickel-Titanium Rotary Endodontic Instruments on Apical Preparation: A Micro-Computed Tomographic Study.

    Science.gov (United States)

    de Almeida, Bernardo Corrêa; Ormiga, Fabíola; de Araújo, Marcos César Pimenta; Lopes, Ricardo Tadeu; Lima, Inayá Corrêa Barbosa; dos Santos, Bernardo Camargo; Gusman, Heloisa

    2015-12-01

    The aim of this study was to make a 3-dimensional comparison of the canal transportation and changes in apical geometry using micro-computed tomographic imaging after canal preparation with K3 (SybronEndo, Orange, CA) and K3XF (SybronEndo) file systems. Twenty-eight mandibular molars were randomly divided into 2 groups according to the rotary system used in instrumentation: K3 or K3XF. The specimens were scanned by micro-computed tomographic imaging before and after instrumentation. Images before and after instrumentation from each group were compared with regard to canal volume, surface area, and structure model index (SMI) (paired t test, P instrumentation, the canals from each group were compared regarding the changes in volume, surface area, SMI, and canal transportation in the last 4 apical mm (t test, P Instrumentation with the 2 rotary systems significantly changed the canal volume, surface area, and SMI (P instrument types concerning these parameters (P > .05). There were no significant differences between the 2 groups with regard to canal transportation in the last 4 apical mm (P > .05). Both rotary systems showed adequate canal preparations with reduced values of canal transportation. Heat treatment did not influence changes in root canal geometry in the apical region. Copyright © 2015 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  9. A vision fusion treatment system based on ATtiny26L

    Science.gov (United States)

    Zhang, Xiaoqing; Zhang, Chunxi; Wang, Jiqiang

    2006-11-01

    Vision fusion treatment is an important and effective project to strabismus children. The vision fusion treatment system based on the principle for eyeballs to follow the moving visual survey pole is put forward first. In this system the original position of visual survey pole is about 35 centimeters far from patient's face before its moving to the middle position between the two eyeballs. The eyeballs of patient will follow the movement of the visual survey pole. When they can't follow, one or two eyeballs will turn to other position other than the visual survey pole. This displacement is recorded every time. A popular single chip microcomputer ATtiny26L is used in this system, which has a PWM output signal to control visual survey pole to move with continuously variable speed. The movement of visual survey pole accords to the modulating law of eyeballs to follow visual survey pole.

  10. Multimicroprocessor system for high-energy physics experiment applications

    International Nuclear Information System (INIS)

    Piska, K.; Falkenberg, W.; Glasneck, C.P.; Pflugbeil, W.

    1982-01-01

    An autonomous modular multicomputer system based on the INTEL 8080 for program development and for application to the high-energy physics experiment 'RISK' is presented. The associated microcomputers (a three-processor configuration is realized) with uniform software systems can perform, in parallel, the interactively-controlled processing and monitoring of data accessible in the common memory block coupled to the processors via the direct shared bus. Data are acquired into the common memory buffer by the main processor, which is linked by the CAMAC interface with the experimental apparatus and optionally with a large-size computer. One microcomputer can be connected with the magnetic tape unit used for data recording. (orig.)

  11. Activities and trends in physical protection modeling with microcomputers

    International Nuclear Information System (INIS)

    Chapman, L.D.; Harlan, C.P.

    1985-01-01

    Sandia National Laboratories developed several models in the mid to late 1970's including the Safeguards Automated Facility Evaluation (SAFE) method. The Estimate of Adversary Sequence Interruption (EASI), the Safeguards Network Analysis Procedure (SNAP), the Brief Adversary Threat Loss Estimator (BATLE), and others. These models were implemented on large computers such as the VAX 11/780 and the CDC machines. With the recent development and widespread use of the IBM PC and other microcomputers, it has become evident that several physical protection models should be made available for use on these microcomputers. Currently, there are programs under way to convert the EASI, SNAP and BATLE models to the IBM PC. The input and analysis using the EASI model has been designed to be very user friendly through the utilization of menu driven options. The SNAP modeling technique will be converted to an IBM PC/AT with many enhancements to user friendliness. Graphical assistance for entering the model and reviewing traces of the simulated output are planned. The BATLE model is being converted to the IBM PC while preserving its interactive nature. The current status of the these developments is reported in this paper

  12. Medical and administrative management of a nuclear medicine department with a microcomputer

    International Nuclear Information System (INIS)

    Legras, B.; Kohler, F.

    1984-01-01

    The use of a microcomputer for data management in a department of Nuclear Medicine has allowed to reduce considerably office work, and supplies the physicians with very useful statistics on the investigations carried out [fr

  13. Investigation of spatial resolution characteristics of an in vivo microcomputed tomography system

    Energy Technology Data Exchange (ETDEWEB)

    Ghani, Muhammad U. [Center for Biomedical engineering and School of Electrical and Computer Engineering, University of Oklahoma, Norman, OK 73019 (United States); Zhou, Zhongxing [Center for Biomedical engineering and School of Electrical and Computer Engineering, University of Oklahoma, Norman, OK 73019 (United States); School of Precision and Optoelectronics Engineering, Tianjin University, Tianjin 300072 (China); Ren, Liqiang; Wong, Molly; Li, Yuhua; Zheng, Bin [Center for Biomedical engineering and School of Electrical and Computer Engineering, University of Oklahoma, Norman, OK 73019 (United States); Yang, Kai [Department of Radiology, Massachusetts General Hospital, 55 Fruit Street, Boston, MA 02114 (United States); Liu, Hong, E-mail: liu@ou.edu [Center for Biomedical engineering and School of Electrical and Computer Engineering, University of Oklahoma, Norman, OK 73019 (United States)

    2016-01-21

    The spatial resolution characteristics of an in vivo microcomputed tomography (CT) system was investigated in the in-plane (x–y), cross plane (z) and projection imaging modes. The microCT system utilized in this study employs a flat panel detector with a 127 µm pixel pitch, a microfocus x-ray tube with a focal spot size ranging from 5–30 µm, and accommodates three geometric magnifications (M) of 1.72, 2.54 and 5.10. The in-plane modulation transfer function (MTF) curves were measured as a function of the number of projections, geometric magnification (M), detector binning and reconstruction magnification (M{sub Recon}). The in plane cutoff frequency (10% MTF) ranged from 2.31 lp/mm (M=1.72, 2×2 binning) to 12.56 lp/mm (M=5.10, 1×1 binning) and a bar pattern phantom validated those measurements. A slight degradation in the spatial resolution was observed when comparing the image reconstruction with 511 and 918 projections, whose effect was visible at the lower frequencies. Small value of M{sub Recon} has little or no impact on the in-plane spatial resolution owning to a stable system. Large value of M{sub Recon} has implications on the spatial resolution and it was evident when comparing the bar pattern images reconstructed with M{sub Recon}=1.25 and 2.5. The cross plane MTF curves showed that the spatial resolution increased as the slice thickness decreased. The cutoff frequencies in the projection imaging mode yielded slightly higher values as compared to the in-plane and cross plane modes at all the geometric magnifications (M). At M=5.10, the cutoff resolution of the projection and cross plane on an ultra-high contrast resolution bar chip phantom were 14.9 lp/mm and 13–13.5 lp/mm. Due to the finite focal spot size of the x-ray tube, the detector blur and the reconstruction kernel functions, the system's spatial resolution does not reach the limiting spatial resolution as defined by the Nyquist's detector criteria with an ideal point source

  14. The Temperature Fuzzy Control System of Barleythe Malt Drying Based on Microcontroller

    Science.gov (United States)

    Gao, Xiaoyang; Bi, Yang; Zhang, Lili; Chen, Jingjing; Yun, Jianmin

    The control strategy of temperature and humidity in the beer barley malt drying chamber based on fuzzy logic control was implemented.Expounded in this paper was the selection of parameters for the structure of the regulatory device, as well as the essential design from control rules based on the existing experience. A temperature fuzzy controller was thus constructed using relevantfuzzy logic, and humidity control was achieved by relay, ensured the situation of the humidity to control the temperature. The temperature's fuzzy control and the humidity real-time control were all processed by single chip microcomputer with assembly program. The experimental results showed that the temperature control performance of this fuzzy regulatory system,especially in the ways of working stability and responding speed and so on,was better than normal used PID control. The cost of real-time system was inquite competitive position. It was demonstrated that the system have a promising prospect of extensive application.

  15. Computer-based expert system aids underground mine planning

    Energy Technology Data Exchange (ETDEWEB)

    Britton, S.G.

    1987-04-01

    Artificial intelligence (AI) systems have been rapidly expanded over the last few years to aid in the decision making processes in a whole range of industries, including the use of machines for operating in high risk/dangerous areas such as at the working faces in longwall mining. Using Prolog software a program for mine management is being developed called CHOOZ. This system can help managers identify staffing problems and change manpower shifts to cope with unexpected labor problems such as absenteeism and sickness. All the programs have been developed for the IBM PC microcomputer.

  16. Dictionary of microelectronics and microcomputer technology. Woerterbuch der Mikroelektronik und Mikrorechnertechnik

    Energy Technology Data Exchange (ETDEWEB)

    Attiyate, Y H; Shah, R R

    1984-01-01

    This bilingual dictionary (German-English and English-German) is to give the general public a clearer idea of the terminology of microelectronics, microcomputers, data processing, and computer science. Each part contains about 7500 terms frequently encountered in practice, about 2000 of which are supplemented by precise explanations.

  17. Microcomputers, desk calculators and process computers for use in radiation protection

    International Nuclear Information System (INIS)

    Burgkhardt, B.; Nolte, G.; Schollmeier, W.; Rau, G.

    1983-01-01

    The goals achievable, or to be pursued, in radiation protection measurement and evaluation by using computers are explained. As there is a large variety of computers available offering a likewise large variety, of performances, use of a computer is justified even for minor measuring and evaluation tasks. The subdivision into: Microcomputers as an installed part of measuring equipment; measuring and evaluation systems with desk calculators; measuring and evaluation systems with process computers is done to explain the importance and extent of the measuring or evaluation tasks and the computing devices suitable for the various purposes. The special requirements to be met in order to fulfill the different tasks are discussed, both in terms of hardware and software and in terms of skill and knowledge of the personnel, and are illustrated by an example showing the usefulness of computers in radiation protection. (orig./HP) [de

  18. Automation by microcomputer of a geodetic distance measuring instrument: The distinvar

    International Nuclear Information System (INIS)

    Bain, G.; Bore, C.; Coosemans, W.; Dupont, J.; Fabre, J.P.; Gavaggio, R.; Peron, F.

    1985-01-01

    The distinvar is an instrument for the precision measurement of distances up to 50 m. This report describes the latest developments at CERN which have improved its resolution to 2 μm and increased its speed of use. Measurements are automated by incorporating a microcomputer programmed in BASIC. (orig.)

  19. Microcomputer simulation of PWR power plant pressurizer

    International Nuclear Information System (INIS)

    Araujo, L.R.A. de; Calixto Neto, J.; Martinez, A.S.; Schirru, R.

    1990-01-01

    It is presented a method for the simulation of the pressurizer behavior of a PWR power plant. The method was implanted in a microcomputer, and it considers all the devices for the pressure control (spray and relief valves, heaters, controller, etc.). The physical phenomena and the PID (Proportional + Integral + Derivative) controller were mathematically represented by linear relations, uncoupled, discretized in the time. There are three different algorithms which take into account the non-linear effects introduced by the variation of the physical properties due to the temperature and pressure, and also the mutual effects between the physical phenomena and the PID controller. (author)

  20. Microcomputer based program for predicting heat transfer under reactor accident conditions. Volume I

    International Nuclear Information System (INIS)

    Cheng, S.C.; Groeneveld, D.C.; Leung, L.K.H.; Wong, Y.L.; Nguyen, C.

    1987-07-01

    A microcomputer based program called Heat Transfer Prediction Software (HTPS) has been developed. It calculates the heat transfer for the tube and bundle geometries for steady state and transient conditions. This program is capable of providing the best estimated of the hot pin temperatures during slow transients for 37- and 28-element CANDU type fuel bundles. The program is designed for an IBM-PC AT/XT (or IBM-PC compatible computer) equipped with a Math Co-processor. The following input parameters are required: pressure, mass flux, hydraulic diameter, and quality. For the steady state case, the critical heat flux (CHF), the critical heat flux temperature, the minimum film boiling temperature, and the minimum film boiling heat flux are the primary outputs. With either the surface heat flux or wall temperature specified, the program determines the heat transfer regime and calculates the surface heat flux, wall temperatures and heat transfer coefficient. For the slow transient case, the pressure, mass flux, quality, and volumetric heat generation rate are the time dependent input parameters required to calculate the hot pin sheath temperatures and surface heat fluxes. A simple routine for generating properties has been developed for light water to support the above program. It contains correlations that have been verified for pressures ranging from 0.6kPa to 30 MPa, and temperatures up to 1100 degrees Celcius. The thermodynamic and transport properties that can be generated from this routine are: density, specific volume, enthalpy, specific heat capacity, conductivity, viscosity, surface tension and Prandtl number for saturated liquid, saturated vapour, subcooled liquid for superheated vapour. A software for predicting flow regime has also been developed. It determines the flow pattern at specific flow conditions, and provides a correction factor for calculating the CHF during partially stratified horizontal flow. The technical bases for the program and its

  1. Microcomputer based program for predicting heat transfer under reactor accident conditions. Volume II

    International Nuclear Information System (INIS)

    Cheng, S.C.; Groeneveld, D.C.; Leung, L.K.H.; Wong, Y.L.; Nguyen, C.

    1987-07-01

    A microcomputer based program called Heat Transfer Prediction Software (HTPS) has been developed. It calculates the heat transfer for tube and bundle geometries for steady state and transient conditions. This program is capable of providing the best estimated of the hot pin temperatures during slow transients for 37- and 28-element CANDU type fuel bundles. The program is designed for an IBM-PC AT/XT (or IBM-PC compatible computer) equipped with a Math Co-processor. The following input parameters are required: pressure, mass flux, hydraulic diameter, and quality. For the steady state case, the critical heat flux (CHF), the critical heat flux temperature, the minimum film boiling temperature, and the minimum film boiling heat flux are the primary outputs. With either the surface heat flux or wall temperature specified, the program determines the heat transfer regime and calculates the surface heat flux, wall temperature and heat transfer coefficient. For the slow transient case, the pressure, mass flux, quality, and volumetric heat generation rate are the time dependent input parameters are required to calculate the hot pin sheath temperatures and surface heat fluxes. A simple routine for generating properties has been developed for light water to support the above program. It contains correlations that have been verified for pressures ranging from 0.6kPa to 30 MPa, and temperatures up to 1100 degrees Celcius. The thermodynamic and transport properties that can be generated from this routine are: density, specific volume, enthalpy, specific heat capacity, conductivity, viscosity, surface tension and Prandtle number for saturated liquid, saturated vapour, subcooled liquid of superheated vapour. A software for predicting flow regime has also been developed. It determines the flow pattern at specific flow conditions, and provides a correction factor for calculating the CHF during partially stratified horizontal flow. The technical bases for the program and its structure

  2. Simulation of Heat Transfer and Electromagnetic Fields of Protected Microcomputers

    Directory of Open Access Journals (Sweden)

    Josef Lakatos

    2006-01-01

    Full Text Available The paper presents results of collaboration between Department of mechatronics and electronics at University of Žilina and VÚVT Engineering a.s. Žilina in area of heat transfer simulations and disturbing electromagnetic radiation simulations in computer construction. The simulations results were used in development of protected microcomputer prototypes in frame of applied research at both of workplaces.

  3. The development of the time-keeping clock with TS-1 single chip microcomputer.

    Science.gov (United States)

    Zhou, Jiguang; Li, Yongan

    The authors have developed a time-keeping clock with Intel 8751 single chip microcomputer that has been successfully used in time-keeping station. The hard-soft ware design and performance of the clock are introduced.

  4. A microcomputer program for coupled cycle burnup calculations

    International Nuclear Information System (INIS)

    Driscoll, M.J.; Downar, T.J.; Taylor, E.L.

    1986-01-01

    A program, designated BRACC (Burnup, Reactivity, And Cycle Coupling), has been developed for fuel management scoping calculations, and coded in the BASIC language in an interactive format for use with microcomputers. BRACC estimates batch and cycle burnups for sequential reloads for a variety of initial core conditions, and permits the user to specify either reload batch properties (enrichment, burnable poison reactivity) or the target cycle burnup. Most important fuel management tactics (out-in or low-leakage loading, coastdown, variation in number of assemblies charged) can be simulated

  5. Microcomputer simulation of nuclear magnetic resonance imaging contrasts

    International Nuclear Information System (INIS)

    Le Bihan, D.

    1985-01-01

    The high information content of magnetic resonance images is due to the multiplicity of its parameters. However, this advantage introduces a difficulty in the interpretation of the contrast: an image is strongly modified according to the visualised parameters. The author proposes a micro-computer simulation program. After recalling the main intrinsic and extrinsic parameters, he shows how the program works and its interest as a pedagogic tool and as an aid for contrast optimisation of images as a function of the suspected pathology [fr

  6. Interfacing of the NICP scanning photometer to an ABC-80 microcomputer

    International Nuclear Information System (INIS)

    Sten, T.A.

    The NICP scanning photometer is regularly used in connection with the sounding rocket projects carried out from Andoeya Rocket Range. When dealing with rockets for auroral studies it is essential to follow the development and movements of auroral forms. For this purpose a data screen is superior to a chart for quick evaluation of the exact elevation and density. An ABC-80 microcomputer has therefore been interfaced to the NICP scanning photometer for on-line display of the optical data. This report gives a description of the interfacing as a guide for further programming. Descriptions of two programs are given in Appendix B to illustrate some of the possibilities with the system. The scientific processing of data is, however, considered beyond the scope of this report. The interfaces described can be used with other computer systems provided two 8-bit input ports for data and two 8-bit output ports are available. (Auth.)

  7. Real-time interferometer phase detection using an LSI-11 microcomputer and high-speed digital techniques

    International Nuclear Information System (INIS)

    Mendell, D.S.

    1978-01-01

    This paper describes the basic design and philosophy of a real-time, interferometer phase-detection system used on the 2XIIB and TMX magnetic-fusion experiments at the Lawrence Livermore Laboratory. This diagnostics system is now a satellite to a host computer and uses high-speed, emitter-coupled logic techniques to derive data on real-time phase relationships. The system's input signals can be derived from interferometer outputs over a wide range of reference frequencies. An LSI-11 microcomputer is the interface between the high-speed phase-detection logic, buffer memory, human interaction, and host computer. Phase data on a storage CRT is immediately displayed after each experimental fusion shot. An operator can interrogate this phase data more closely from an interactive control panel, while the host computer is simultaneously examining the system's buffer memory or arming the system for the next shot

  8. Design of detection module for smart ligthting system

    OpenAIRE

    Matveev, I. G.; Goponenko, A. S.

    2015-01-01

    The paper considers a smart lighting system based on Beaglebone microcomputer. The analysis of existing motion and presence sensors was carried out and then used as a basis for design of a detection system. The detection system and the corresponding connection solution for a smart lighting system were developed. Using the designed smart lighting system, experimental studies were carried out.

  9. Systems Analysis Programs for Hands-on Integrated Reliability Evaluations (SAPHIRE), Version 5.0. Volume 5, Systems Analysis and Risk Assessment (SARA) tutorial manual

    International Nuclear Information System (INIS)

    Sattison, M.B.; Russell, K.D.; Skinner, N.L.

    1994-07-01

    The Systems Analysis Programs for Hands-on Integrated Reliability Evaluations (SAPHIRE) refers to a set of several microcomputer programs that were developed to create and analyze probabilistic risk assessments (PRAs) primarily for nuclear power plants. This volume is the tutorial manual for the Systems Analysis and Risk Assessment (SARA) System Version 5.0, a microcomputer-based system used to analyze the safety issues of a open-quotes familyclose quotes [i.e., a power plant, a manufacturing facility, any facility on which a probabilistic risk assessment (PRA) might be performed]. A series of lessons is provided that guides the user through some basic steps common to most analyses performed with SARA. The example problems presented in the lessons build on one another, and in combination, lead the user through all aspects of SARA sensitivity analysis capabilities

  10. A MICROCOMPUTER LINEAR PROGRAMMING PACKAGE: AN ALTERNATIVE TO MAINFRAMES

    OpenAIRE

    Laughlin, David H.

    1984-01-01

    This paper presents the capabilities and limitations of a microcomputer linear programming package. The solution algorithm is a version of the revised simplex. Rapid problem entry, user ease of operation, sensitivity analyses on objective function and right hand sides are advantages. A problem size of 150 activities and 64 constraints can be solved in present form. Due to problem size, limitations and lack of parametric and integer programming routines, this package is thought to have the mos...

  11. MultiSimPC: a multilevel logic simulator for microcomputers

    OpenAIRE

    Kelly, John S.

    1986-01-01

    Approved for public release; distribution is unlimited This thesis describes extensions to a multilevel VLSI logic simulator named MultiSim. Originally developed by Dr. Ausif Mahmood of the Washington State University for large minicomputers such as the VAX-11/780; MultiSim is now operational on desktop microcomputers costing only a few thousand dollars. In addition, MultiSim has been expanded to include provisions for adding user-defined primitive cells to the circuit library, true mu...

  12. Use of microcomputers in the IUCF control system

    International Nuclear Information System (INIS)

    Collins, J.C.; Manwaring, W.

    1982-01-01

    To lighten the load on the control computer, to realize the advantages inherent in modularized systems and simultaneously to improve systems not previously under computer control requires that intelligence be distributed throughout the IUCF control system. Four microprocessor systems are now up and running. The 162 cm scattering chamber has a microprocessor based vacuum control system which supports fully-automatic pumpdown, but which appears to the operator to be identical to the older hard-wired system. The same chamber has a microprocessor controller for two detector arms and the target table with manual or external computer settable ''seek'' functions; software interlock features prevent damage to detectors. A status annunciator system alerts the operator to failures signaled by contact closures or sensor values falling outside of predefined ranges. Finally, closed loop beam positioning using steering magnets and slits may be turned on or off by the controls computer. All these applications were designed to fit the existing control system hardware and built entirely at IUCF using commercial chips

  13. A Novel Electric Bicycle Battery Monitoring System Based on Android Client

    Directory of Open Access Journals (Sweden)

    Chuanxue Song

    2017-01-01

    Full Text Available The battery monitoring system (BMS plays a crucial role in maintaining the safe operation of the lithium battery electric bicycle and prolonging the life of the battery pack. This paper designed a set of new battery monitoring systems based on the Android system and ARM single-chip microcomputer to enable direct management of the lithium battery pack and convenient monitoring of the state of the battery pack. The BMS realizes the goal of monitoring the voltage, current, and ambient temperature of lithium batteries, estimating the state of charge (SOC and state of health (SOH, protecting the battery from abuse during charging or discharging, and ensuring the consistency of the batteries by integrating the passive equalization circuit. The BMS was proven effective and feasible through several tests, including charging/discharging, estimation accuracy, and communication tests. The results indicated that the BMS could be used in the design and application of the electric bicycle.

  14. An Evaluation of the Availability and Application of Microcomputer Software Programs for Use in Air Force Ground Transportation Squadrons

    Science.gov (United States)

    1988-09-01

    software programs capable of being used on a microcomputer will be considered for analysis. No software intended for use on a miniframe or mainframe...Dial-A-Log consists of a program written in a computer language called L-10 that is run on a DEC-20 miniframe . The combination of the specific...proliferation of software dealing with microcomputers. Instead, they were geared more towards managing the use of miniframe or mainframe computer

  15. In vitro ceramic scaffold mineralization: comparison between histological and micro-computed topographical analysis

    NARCIS (Netherlands)

    Thimm, B.W.; Wechsler, O.; Bohner, M.; Müller, R.; Hofmann, S.

    2013-01-01

    The porous structure of beta-tricalcium phosphate (b-TCP) scaffolds was assessed by conventional histomor- phometry and micro-computed tomography (micro-CT) to evaluate the substitutability of time-consuming histomor- phometry by rapid micro-CT. Extracellular matrix mineral- ization on human

  16. Micro-computed tomography of pupal metamorphosis in the solitary bee Megachile rotundata

    Science.gov (United States)

    Insect metamorphosis involves a complex change in form and function, but most of these changes are internal and treated as a black box. In this study, we examined development of the solitary bee, Megachile rotundata, using micro-computed tomography (µCT) and digital volume analysis. We describe deve...

  17. Microcomputer-based systems for automatic control of sample irradiation and chemical analysis of short-lived isotopes

    International Nuclear Information System (INIS)

    Bourret, S.C.

    1974-01-01

    Two systems resulted from the need for the study of the nuclear decay of short-lived radionuclides. Automation was required for better repeatability, speed of chemical separation after irradiation and for protection from the high radiation fields of the samples. A MCS-8 computer was used as the nucleus of the automatic sample irradiation system because the control system required an extensive multiple-sequential circuit. This approach reduced the sequential problem to a computer program. The automatic chemistry control system is a mixture of a fixed and a computer-based programmable control system. The fixed control receives the irradiated liquid sample from the reactor, extracts the liquid and disposes of the used sample container. The programmable control executes the chemistry program that the user has entered through the teletype. (U.S.)

  18. Microcomputer-based system for 24-hour recording of oesophageal motility and pH profile with automated analysis

    NARCIS (Netherlands)

    Breedijk, M.; Smout, A. J.; van der Zouw, C.; Verwey, H.; Akkermans, L. M.

    1989-01-01

    A system developed for long-term simultaneous recording of oesophageal motility and pH in the ambulant patient is described. The system consists of a microprocessor based data-acquisition and preprocessing device, a personal computer for postprocessing, report generation and data storage, a

  19. Design of digital voice storage and playback system

    Science.gov (United States)

    Tang, Chao

    2018-03-01

    Based on STC89C52 chip, this paper presents a single chip microcomputer minimum system, which is used to realize the logic control of digital speech storage and playback system. Compared with the traditional tape voice recording system, the system has advantages of small size, low power consumption, The effective solution of traditional voice recording system is limited in the use of electronic and information processing.

  20. Digital remote control system for power supplies of particle channel magnetooptical elements

    International Nuclear Information System (INIS)

    Vetrov, P.B.; Ermolina, G.P.; Kuznetsov, V.S.; Mojbenko, A.N.

    1986-01-01

    Current control of magnetooptical elements of accelerator particle channels is based on control of reference voltage of current stabilizers. Advent of industrial multidigit (12 bits) integral analog-to-digital converters permitted to develop simple digital sources of reference voltage. A digital control system of 30 spatially remoted power supplies of magnetooptical elements of particle channels on the basis of the ''Elektronika-60'' microcomputer is described. The microcomputer is connected by the standard communication line (20 mA) with the SM-4 computer. The ''Summa'' crate is connected with the microcomputer through the branch driver. Digit data are transmitted by the multibranch trunk of sequential communication (Manchester-2 code) at the rate of 0.5 Mband. Feedback was realized by connection of analog signals through the distributed commutator to the measuring line with a digital voltmeter

  1. Atomic absorption spectrometer readout and data reduction using the LSI-11 microcomputer

    International Nuclear Information System (INIS)

    Allen, M.J.; Wikkerink, R.W.

    1978-01-01

    Some common instruments found in the chemistry laboratory have analog chart recorder output as their primary data readout media. Data reduction from this medium is slow and relatively inaccurate. This paper describes how to interface a single LSI-11 microcomputer to PERKIN-ELMER models 603 and 303 Atomic Absorption Spectrophotometers

  2. A Microcomputer Program that Simulates the Baumol-Tobin Transactions Demand for Money.

    Science.gov (United States)

    Beckman, Steven

    1987-01-01

    This article describes an economic model dealing with the demand for money and a microcomputer program which enables students to experiment with cash management techniques. By simulating personal experiences, the program teaches how changes in income, interest rates, and charges for exchanging bonds and cash affect money demand. (Author/JDH)

  3. Integrated Reliability and Risk Analysis System (IRRAS)

    International Nuclear Information System (INIS)

    Russell, K.D.; McKay, M.K.; Sattison, M.B.; Skinner, N.L.; Wood, S.T.; Rasmuson, D.M.

    1992-01-01

    The Integrated Reliability and Risk Analysis System (IRRAS) is a state-of-the-art, microcomputer-based probabilistic risk assessment (PRA) model development and analysis tool to address key nuclear plant safety issues. IRRAS is an integrated software tool that gives the user the ability to create and analyze fault trees and accident sequences using a microcomputer. This program provides functions that range from graphical fault tree construction to cut set generation and quantification. Version 1.0 of the IRRAS program was released in February of 1987. Since that time, many user comments and enhancements have been incorporated into the program providing a much more powerful and user-friendly system. This version has been designated IRRAS 4.0 and is the subject of this Reference Manual. Version 4.0 of IRRAS provides the same capabilities as Version 1.0 and adds a relational data base facility for managing the data, improved functionality, and improved algorithm performance

  4. Research on numerical control system based on S3C2410 and MCX314AL

    Science.gov (United States)

    Ren, Qiang; Jiang, Tingbiao

    2008-10-01

    With the rapid development of micro-computer technology, embedded system, CNC technology and integrated circuits, numerical control system with powerful functions can be realized by several high-speed CPU chips and RISC (Reduced Instruction Set Computing) chips which have small size and strong stability. In addition, the real-time operating system also makes the attainment of embedded system possible. Developing the NC system based on embedded technology can overcome some shortcomings of common PC-based CNC system, such as the waste of resources, low control precision, low frequency and low integration. This paper discusses a hardware platform of ENC (Embedded Numerical Control) system based on embedded processor chip ARM (Advanced RISC Machines)-S3C2410 and DSP (Digital Signal Processor)-MCX314AL and introduces the process of developing ENC system software. Finally write the MCX314AL's driver under the embedded Linux operating system. The embedded Linux operating system can deal with multitask well moreover satisfy the real-time and reliability of movement control. NC system has the advantages of best using resources and compact system with embedded technology. It provides a wealth of functions and superior performance with a lower cost. It can be sure that ENC is the direction of the future development.

  5. Moessbauer spectrometer based on UNO-4096-90 accumulator and Elektronika D3-28 microcomputer for simultaneous recording of four spectra

    International Nuclear Information System (INIS)

    Romanov, E.S.; Ivoilov, N.G.

    1986-01-01

    A buffer memory unit and an interface for the UNO-4096-90 accumulator with an Elektronika D3-28 microcomputer are described that allow simultaneous recording of four Moessbauer spectra with zero dead time. For complete elimination of dead time, the pulses from each detector are fed to two buffer counters units, which operate alternately in the write and interrogate modes. This organization of the buffer memory also completely eliminates the effect of the sensors on one another. The use of these circuits does not require any modifications of the computer or accumulator

  6. A microcomputer based multi parametric system for nuclear data acquisition and processing

    International Nuclear Information System (INIS)

    Toledo Acosta B, Rene; Osorio Deliz F, Juan; Arista Romeu, Eduardo; Perez Sanchez, Reinaldo; Lopes Torres, E.

    1997-01-01

    A four-parameter Multi parametric System for the acquisition and processing of nuclear data is described. It is characterized for its flexibility and relatively low cost, also guaranteeing a high acquisition capacity. The system allows to be utilized in a multi parametric manner, in pulse height analysis or in many combination of both for parameter. It is described the hardware and the software of the system

  7. Development and Experimental Investigations of Motion Detection Module for Smart Lighting System

    OpenAIRE

    Matveev, I.; Siemens, E.; Yurchenko, Aleksey Vasilievich; Kuznetsov, D.

    2016-01-01

    This work considers motion sensors as parts of the smart lighting system on basis of Beaglebone microcomputer. Detection system is designed for the smart lighting system. Experimental investigations of the detection system were made with different motion sensors. Based on the results comparative analysis was performed and optimal conditions for the detection system operation were found.

  8. Detecting and visualizing internal 3D oleoresin in agarwood by means of micro-computed tomography

    International Nuclear Information System (INIS)

    Khairiah Yazid; Roslan Yahya; Mat Rosol Awang

    2012-01-01

    Detection and analysis of oleoresin is particularly significant since the commercial value of agarwood is related to the quantity of oleoresins that are present. A modern technique of non-destructive may reach the interior region of the wood. Currently, tomographic image data in particular is most commonly visualized in three dimensions using volume rendering. The aim of this paper is to explore the potential of high resolution non-destructive 3D visualization technique, X-ray micro-computed tomography, as imaging tools to visualize micro-structure oleoresin in agarwood. Investigations involving desktop X-ray micro-tomography system on high grade agarwood sample, performed at the Centre of Tomography in Nuclear Malaysia, demonstrate the applicability of the method. Prior to experiments, a reference test was conducted to stimulate the attenuation of oleoresin in agarwood. Based on the experiment results, micro-CT imaging with voxel size 7.0 μm is capable to of detecting oleoresin and pores in agarwood. This imaging technique, although sophisticated can be used for standard development especially in grading of agarwood for commercial activities. (author)

  9. Computer-controlled data acquisition system for the ISX-B neutral injection system

    International Nuclear Information System (INIS)

    Edmonds, P.H.; Sherrill, B.; Pearce, J.W.

    1980-05-01

    A data acquisition system for the Impurity Study Experiment (ISX-B) neutral injection system at the Oak Ridge National Laboratory is presented. The system is based on CAMAC standards and is controlled by a MIK-11/2 microcomputer. The system operates at the ion source high voltage on the source table, transmitting the analyzed data to a terminal at ground potential. This reduces the complexity of the communications link and also allows much flexibility in the diagnostics and eventual control of the beam line

  10. Communication interface of computerized automatic fire alarm system

    International Nuclear Information System (INIS)

    Yu Hongmei; Zhu Liqun; Fang Shaohong; Du Chengbao

    1997-01-01

    The problems of communication between multiple single-chip computers and microcomputer have been solved by the way of hardware and software. The automatic fire alarm system is realized by using the serial port both on single-chip computer and microcomputer

  11. A microcomputer real-time monitor for the control of a particle accelerator

    International Nuclear Information System (INIS)

    Ouali, M.

    1977-01-01

    The physical management of a particle accelerator requests the supervision and the control of a great number of parameters and various devices. A hierarchically structured multicomputer control system was implemented on the Synchrocyclotron of the 'Institut de Physique Nucleaire' at Orsay (France). A set of 3 microcomputers MICRAL (manufactured in France around an Intel 8080 microprocessor chip) is connected through a CAMAC link to an IBM 1130 central computer used for the general control. At the lowest level, measurements and supervisions are made by the means of special hardwired systems built in the Laboratory (the CSTIs). On the other hand, some measurements are done by using a conventional industrial data acquisition system. All these systems are managed by the 3 MICRALs, as also some independent devices (function generator, radioprotection beacons, beam profile encoders). A real-time monitor resident in the MICRAL computers is responsible for task activations, resource allocation and data exchange management, especially with the main control computer. It uses for the 6 interrupt levels of the MICRAL and it builds and manages in the memory a set of descriptive block and of data stacks [fr

  12. The Ant and the Grasshopper: A Program for Adopting Microcomputer Graphics in the Arts.

    Science.gov (United States)

    Youngblood, Michael S.

    1988-01-01

    Discusses the major reasons why microcomputers have not yet become commonplace in the arts and describes how the College of Communications and Fine Arts at Southern Illinois University (Carbondale) researched, planned, and implemented a college-wide computer technology program. (GEA)

  13. A simple dynamic model and transient simulation of the nuclear power reactor on microcomputers

    Energy Technology Data Exchange (ETDEWEB)

    Han, Yang Gee; Park, Cheol [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1998-12-31

    A simple dynamic model is developed for the transient simulation of the nuclear power reactor. The dynamic model includes the normalized neutron kinetics model with reactivity feedback effects and the core thermal-hydraulics model. The main objective of this paper demonstrates the capability of the developed dynamic model to simulate various important variables of interest for a nuclear power reactor transient. Some representative results of transient simulations show the expected trends in all cases, even though no available data for comparison. In this work transient simulations are performed on a microcomputer using the DESIRE/N96T continuous system simulation language which is applicable to nuclear power reactor transient analysis. 3 refs., 9 figs. (Author)

  14. A simple dynamic model and transient simulation of the nuclear power reactor on microcomputers

    Energy Technology Data Exchange (ETDEWEB)

    Han, Yang Gee; Park, Cheol [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1997-12-31

    A simple dynamic model is developed for the transient simulation of the nuclear power reactor. The dynamic model includes the normalized neutron kinetics model with reactivity feedback effects and the core thermal-hydraulics model. The main objective of this paper demonstrates the capability of the developed dynamic model to simulate various important variables of interest for a nuclear power reactor transient. Some representative results of transient simulations show the expected trends in all cases, even though no available data for comparison. In this work transient simulations are performed on a microcomputer using the DESIRE/N96T continuous system simulation language which is applicable to nuclear power reactor transient analysis. 3 refs., 9 figs. (Author)

  15. System Analysis and Risk Assessment system (SARA) Version 4.0

    International Nuclear Information System (INIS)

    Sattison, M.B.; Russell, K.D.; Skinner, N.L.

    1992-01-01

    This NUREG is the tutorial for the System Analysis and Risk Assessment System (SARA) Version 4.0, a microcomputer-based system used to analyze the safety issues of a family [i.e., a power plant, a manufacturing facility, any facility on which a probabilistic risk assessment (PRA) might be performed]. A series of lessons are provided that walk the user through some basic steps common to most analyses performed with SARA. The example problems presented in the lessons build on one another, and in combination, lead the user through all aspects of SARA sensitivity analysis

  16. Research on automatic control system of greenhouse

    Science.gov (United States)

    Liu, Yi; Qi, Guoyang; Li, Zeyu; Wu, Qiannan; Meng, Yupeng

    2017-03-01

    This paper introduces a kind of automatic control system of single-chip microcomputer and a temperature and humidity sensor based on the greenhouse, describes the system's hardware structure, working principle and process, and a large number of experiments on the effect of the control system, the results show that the system can ideally control temperature and room temperature and humidity, can be used in indoor breeding and planting, and has the versatility and portability.

  17. An optical system for controlling ion source parameters

    International Nuclear Information System (INIS)

    Zhang Baifang; Liu Zhenhao; Jiang Yi; Xu Zhengjia

    1999-01-01

    An optical control system used for adjusting the source's parameters of an ion separator is described. There are two slice microcomputers at HV terminal and the ground respectively. These microcomputers communicate each other with the full-duplex mode through two pieces of optical fiber, in which many parameters are time-share transmitted in the form of optical pulse. This system can stabilize the arc current and temperature, adjust and display all parameters and has safe-guard ability. At HV terminal, the optical coupling technique is used for connecting the CPU and the ion source, and at the ground the CPU can communicate with a control microcomputer

  18. Design of Moisture Content Detection System

    Science.gov (United States)

    Wang, W. C.; Wang, L.

    In this paper, a method for measuring the moisture content of grain was presented based on single chip microcomputer and capacitive sensor. The working principle of measuring moisture content is introduced and a concentric cylinder type of capacitive sensor is designed, the signal processing circuits of system are described in details. System is tested in practice and discussions are made on the various factors affecting the capacitive measuring of grain moisture based on the practical experiments, experiment results showed that the system has high measuring accuracy and good controlling capacity.

  19. Application of drive circuit based on L298N in direct current motor speed control system

    Science.gov (United States)

    Yin, Liuliu; Wang, Fang; Han, Sen; Li, Yuchen; Sun, Hao; Lu, Qingjie; Yang, Cheng; Wang, Quanzhao

    2016-10-01

    In the experiment of researching the nanometer laser interferometer, our design of laser interferometer circuit system is up to the wireless communication technique of the 802.15.4 IEEE standard, and we use the RF TI provided by Basic to receive the data on speed control system software. The system's hardware is connected with control module and the DC motor. However, in the experiment, we found that single chip microcomputer control module is very difficult to drive the DC motor directly. The reason is that the DC motor's starting and braking current is larger than the causing current of the single chip microcomputer control module. In order to solve this problem, we add a driving module that control board can transmit PWM wave signal through I/O port to drive the DC motor, the driving circuit board can come true the function of the DC motor's positive and reversal rotation and speed adjustment. In many various driving module, the L298N module's integrated level is higher compared with other driver module. The L298N model is easy to control, it not only can control the DC motor, but also achieve motor speed control by modulating PWM wave that the control panel output. It also has the over-current protection function, when the motor lock, the L298N model can protect circuit and motor. So we use the driver module based on L298N to drive the DC motor. It is concluded that the L298N driver circuit module plays a very important role in the process of driving the DC motor in the DC motor speed control system.

  20. Research on single-chip microcomputer controlled rotating magnetic field mineralization model

    Science.gov (United States)

    Li, Yang; Qi, Yulin; Yang, Junxiao; Li, Na

    2017-08-01

    As one of the method of selecting ore, the magnetic separation method has the advantages of stable operation, simple process flow, high beneficiation efficiency and no chemical environment pollution. But the existing magnetic separator are more mechanical, the operation is not flexible, and can not change the magnetic field parameters according to the precision of the ore needed. Based on the existing magnetic separator is mechanical, the rotating magnetic field can be used for single chip microcomputer control as the research object, design and trial a rotating magnetic field processing prototype, and through the single-chip PWM pulse output to control the rotation of the magnetic field strength and rotating magnetic field speed. This method of using pure software to generate PWM pulse to control rotary magnetic field beneficiation, with higher flexibility, accuracy and lower cost, can give full play to the performance of single-chip.

  1. Microprocessor system for data acquisition processing and display for Auger electrons spectrometer

    International Nuclear Information System (INIS)

    Pawlowski, Z.; Cudny, W.; Hildebrandt, S.; Marzec, J.; Walentek, J.; Zaremba, K.

    1984-01-01

    Data acquisition system for Auger electron spectrometry is developed. The system is used for chemical and structural analysis of materials and consists of a cylindrical mirror analyzer being a measuring spectrometer device, CAMAC unit and control unit. The control unit comprises a microcomputer based on INTEL 8080 microprocessor and display

  2. BIBLIO: A Computer System Designed to Support the Near-Library User Model of Information Retrieval.

    Science.gov (United States)

    Belew, Richard K.; Holland, Maurita Peterson

    1988-01-01

    Description of the development of the Information Exchange Facility, a prototype microcomputer-based personal bibliographic facility, covers software selection, user selection, overview of the system, and evaluation. The plan for an integrated system, BIBLIO, and the future role of libraries are discussed. (eight references) (MES)

  3. The quantitative assessment of peri-implant bone responses using histomorphometry and micro-computed tomography.

    NARCIS (Netherlands)

    Schouten, C.; Meijer, G.J.; Beucken, J.J.J.P van den; Spauwen, P.H.M.; Jansen, J.A.

    2009-01-01

    In the present study, the effects of implant design and surface properties on peri-implant bone response were evaluated with both conventional histomorphometry and micro-computed tomography (micro-CT), using two geometrically different dental implants (Screw type, St; Push-in, Pi) either or not

  4. TMX magnet control system

    International Nuclear Information System (INIS)

    Goerz, D.A.

    1978-01-01

    A control system utilizing a microcomputer has been developed that controls the power supplies driving the Tandem Mirror Experiment (TMX) magnet set and monitors magnet coil operation. The magnet set consists of 18 magnet coils that are driven by 26 dc power supplies. There are two possible modes of operation with this system: a pulse mode where the coils are pulsed on for several seconds with a dc power consumption of 16 MW; and a continuous mode where the coils can run steady state at 10 percent of maximum current ratings. The processor has been given an active control role and serves as an interface between the operator and electronic circuitry that controls the magnet power supplies. This microcomputer also collects and processes data from many analog singal monitors in the coil circuits and numerous status signals from the supplies. Placing the microcomputer in an active control role has yielded a compact, cost effective system that simplifies the magnet system operation and has proven to be very reliable. This paper will describe the TMX magnet control sytem and discuss its development

  5. The design and performance of the parallel multiprocessor nuclear physics data acquisition system, DAPHNE

    International Nuclear Information System (INIS)

    Welch, L.C.; Moog, T.H.; Daly, R.T.; Videbaek, F.

    1987-05-01

    The ever increasing complexity of nuclear physics experiments places severe demands on computerized data acquisition systems. A natural evolution of these systems, taking advantages of the independent nature of ''events,'' is to use identical parallel microcomputers in a front end to simultaneously analyze separate events. Such a system has been developed at Argonne to serve the needs of the experimental program of ATLAS, a new superconducting heavy-ion accelerator and other on-going research. Using microcomputers based on the National Semiconductor 32016 microprocessor housed in a Multibus I cage, CPU power equivalent to several VAXs is obtained at a fraction of the cost of one VAX. The front end interfacs to a VAX 11/750 on which an extensive user friendly command language based on DCL resides. The whole system, known as DAPHNE, also provides the means to reply data using the same command language. Design concepts, data structures, performance, and experience to data are discussed

  6. MONK 6.3 code new version for microcomputers and its impact on the safety-criticality analysis

    International Nuclear Information System (INIS)

    Albornoz, A.F.; Jatuff, F.E.

    1994-01-01

    The Monte Carlo method is utilized in neutronics in different fields, such as critical experiment analysis, shielding and criticality-safety analysis. This broad use of is due mainly to its great ability in geometrical representation. In this work it is presented in detail the modifications made on version 6.3 of english code MONK, in order to install it in a system based in microcomputers. The description of some enhancements made to the code are also described. The modifications basically comprised to rewrite code with non-standard use of FORTRAN, and to modify the multidimensional arrays arithmetic in order to save another non-standard use of language. The random number generator was also tested, and it was recognized that it presented a layer structure like all congruent-linear generators. For this reason, it was changed by another with better randomness characteristics. The economic motivations that promote down sizing work, the difficulties found in reorganizing group work, and the impact on the quality of safety analysis of facilities with fissile material are also discussed. (author)

  7. Microcomputer based system to control the load of a capacitor array in the TJ-1 Tokamak

    International Nuclear Information System (INIS)

    Alberdi Primicia, J.; Asenjo, L.; Sanz, J.A.

    1990-01-01

    The power to create the magnetic field in the TJ-1 TOKAMAK is provide by an array of 16 capacitor sets. The total capacity of this array is 8.1F. This work describes a computer system based on the Motorola M-6800 microprocessor which controls the load of the capacitor set-and establishes the conditions for the reactor trigger. (author)

  8. Microcomputer Based System to control the Load of a Capacitor Array in the TJ-1 Tokamak

    International Nuclear Information System (INIS)

    Alberdi, J.; Asenso, L.; Sanz, J. A.

    1990-01-01

    The power to create the magnetic fields in the TJ-1 Tokamak is provides by an array of 16 capacitor sets. The total capacity of this array is 8. 1F. This work describes a computer system based on the Motorola M-6800 micro- processor which controls the load of the capacitor set and stablished the conditions for the reactor trigger. (Author)

  9. Dealing with distributed intelligence in monitoring and control systems

    International Nuclear Information System (INIS)

    McLaren, R.A.

    1981-01-01

    The Euorpean Hybrid Spectrometer is built up of many individual detectors, each having widely varying monitoring and control requirements. With the advent of cheap microprocessor systems a shift from the concept of a single monitoring and control computer of that of distributed intelligent controllers has been economically feasible. A detector designer can now thoroughly test and debug a complete monitoring and control system on a local, dedicated micro-computer, while during operation, the central computer can be relieved of many simple repetitive tasks. Rapidly, however, it has become obvious that the designers of these systems have to take into account the final operational environment and build into both the hardware and software, features allowing easy integration into a central monitoring and control chain. In addition, the problems of maintenance and enventual modification have to be taken into consideration early in the development. Examples of currently operational systems will be briefly described to demonstrate how a set of basic guidelines plus standardisation of hardware/software can minimise the problems of integration and maintenance. Based on practical experience gained in the European Hybrid Spectrometer, investigations are proceeding on various possible alternatives for future micro-computer based monitoring and control systems. (orig.)

  10. Finite element analysis of the mechanical properties of cellular aluminium based on micro-computed tomography

    International Nuclear Information System (INIS)

    Veyhl, C.; Belova, I.V.; Murch, G.E.; Fiedler, T.

    2011-01-01

    Research highlights: → Elastic and plastic anisotropy is observed for both materials → Both show qualitatively similar characteristics with quantitative differences → Distinctly higher mechanical properties for closed-cell foam → The 'big' and 'small' models show good agreement for the closed-cell foam. - Abstract: In the present paper, the macroscopic mechanical properties of open-cell M-Pore sponge (porosity of 91-93%) and closed-cell Alporas foam (porosity of 80-86%) are investigated. The complex geometry of these cellular materials is scanned by micro-computed tomography and used in finite element (FE) analysis. The mechanical properties are determined by uni-axial compression simulations in three perpendicular directions (x-, y- and z-direction). M-Pore and Alporas exhibit the same qualitative mechanical characteristics but with quantitative differences. In both cases, strong anisotropy is observed for Young's modulus and the 0.002 offset yield stress. Furthermore, for the investigated relative density range a linear dependence between relative density and mechanical properties is found. Finally, a distinctly higher Young's modulus and 0.002 offset yield stress is observed for Alporas.

  11. Conversion and distribution of bibliographic information for further use on microcomputers with database software such as CDS/ISIS

    International Nuclear Information System (INIS)

    Nieuwenhuysen, P.; Besemer, H.

    1990-05-01

    This paper describes methods to work on microcomputers with data obtained from bibliographic and related databases distributed by online data banks, on CD-ROM or on tape. Also, we mention some user reactions to this technique. We list the different types of software needed to perform these services. Afterwards, we report about our development of software, to convert data so that they can be entered into UNESCO's program named CDS/ISIS (Version 2.3) for local database management on IBM microcomputers or compatibles; this software allows the preservation of the structure of the source data in records, fields, subfields and field occurrences. (author). 10 refs, 1 fig

  12. The automatic extraction of pitch perturbation using microcomputers: some methodological considerations.

    Science.gov (United States)

    Deem, J F; Manning, W H; Knack, J V; Matesich, J S

    1989-09-01

    A program for the automatic extraction of jitter (PAEJ) was developed for the clinical measurement of pitch perturbations using a microcomputer. The program currently includes 12 implementations of an algorithm for marking the boundary criteria for a fundamental period of vocal fold vibration. The relative sensitivity of these extraction procedures for identifying the pitch period was compared using sine waves. Data obtained to date provide information for each procedure concerning the effects of waveform peakedness and slope, sample duration in cycles, noise level of the analysis system with both direct and tape recorded input, and the influence of interpolation. Zero crossing extraction procedures provided lower jitter values regardless of sine wave frequency or sample duration. The procedures making use of positive- or negative-going zero crossings with interpolation provided the lowest measures of jitter with the sine wave stimuli. Pilot data obtained with normal-speaking adults indicated that jitter measures varied as a function of the speaker, vowel, and sample duration.

  13. Whenever You Use a Computer You Are Using a Program Called an Operating System.

    Science.gov (United States)

    Cook, Rick

    1984-01-01

    Examines design, features, and shortcomings of eight disk-based operating systems designed for general use that are popular or most likely to affect the future of microcomputing. Included are the CP/M family, MS-DOS, Apple DOS/ProDOS, Unix, Pick, the p-System, TRSDOS, and Macintosh/Lisa. (MBR)

  14. A failure detection and isolation system simulator

    International Nuclear Information System (INIS)

    Assumpcao Filho, E.O.; Nakata, H.

    1990-04-01

    A failure detection and isolation system (FDI) simulation program has been developed for IBM-PC microcomputers. The program, based on the sequential likelihood ratio testing method developed by A. Wald, was implemented with the Monte-Carlo technique. The calculated failure detection rate was favorably compared against the wind-tunnel experimental redundant temperature sensors. (author) [pt

  15. The design, creation, and performance of the parallel multiprocessor nuclear physics data acquisition system, DAPHNE

    International Nuclear Information System (INIS)

    Welch, L.C.; Moog, T.H.; Daly, R.T.; Videbaek, F.

    1986-01-01

    The ever increasing complexity of nuclear physics experiments places severe demands on computerized data acquisition systems. A natural evolution of these system, taking advantage of the independent nature of ''events'', is to use identical parallel microcomputers in a front end to simultaneously analyze separate events. Such a system has been developed at Argonne to serve the needs of the experimental program of ATLAS, a new superconducting heavy-ion accelerator and other on-going research. Using microcomputers based on the National Semiconductor 32016 microprocessor housed in a Multibus I cage, multi-VAX cpu power is obtained at a fraction of the cost of one VAX. The front end interfaces to a VAX 750 on which an extensive user friendly command language based on DCL resides. The whole system, known as DAPHNE, also provides the means to replay data using the same command language. Design concepts, data structures, performance, and experience to data are discussed. 5 refs., 2 figs

  16. Automated TLD system for gamma radiation monitoring

    International Nuclear Information System (INIS)

    Nyberg, P.C.; Ott, J.D.; Edmonds, C.M.; Hopper, J.L.

    1979-01-01

    A gamma radiation monitoring system utilizing a commercially available TLD reader and unique microcomputer control has been built to assess the external radiation exposure to the resident population near a nuclear weapons testing facility. Maximum use of the microcomputer was made to increase the efficiency of data acquisition, transmission, and preparation, and to reduce operational costs. The system was tested for conformance with an applicable national standard for TLD's used in environmental measurements

  17. Automation of testing the metrological reliability of nondestructive control systems

    International Nuclear Information System (INIS)

    Zhukov, Yu.A.; Isakov, V.B.; Karlov, Yu.K.; Kovalevskij, Yu.A.

    1987-01-01

    Opportunities of microcomputers are used to solve the problem of testing control-measuring systems. Besides the main program the program of data processing when characterizing the nondestructive control systems is written in the microcomputer. The program includes two modules. The first module contains tests-programs, by which accuracy of functional elements of the microcomputer and interface elements with issuing a message to the operator on readiness of the elements for operation and failure of a certain element are determined. The second module includes: calculational programs when determining metrological reliability of measuring channel reliability, a calculational subprogram for random statistical measuring error, time instability and ''dead time''. Automation of testing metrological reliability of the nondestructive control systems increases reliability of determining metrological parameters and reduces time of system testing

  18. Networking the Home and University: How Families Can Be Integrated into Proximate/Distant Computer Systems.

    Science.gov (United States)

    Watson, J. Allen; And Others

    1989-01-01

    Describes study that was conducted to determine the feasibility of networking home microcomputers with a university mainframe system in order to investigate a new family process research paradigm, as well as the design and function of the microcomputer/mainframe system. Test instrumentation is described and systems' reliability and validity are…

  19. 3D microcomputer tomograph for materials development and testing of components

    International Nuclear Information System (INIS)

    Riesemeier, H.; Goebbels, J.; Illerhaus, B.; Onel, Y.; Reimers, P.

    1993-01-01

    Examples prove the great capacity of 3D microcomputerized tomography in characterising new materials, particularly in the development stage. Cracks and delamination after deliberate damage are shown with good resolution. In showing complex structures, the possibility of picture reproduction of any sectional plane is of great use. 3D microcomputer tomography is therefore a futuristic process in materials research and for small of component series in production, eg: in the aircraft and space industry. (orig./DG) [de

  20. Integrated Reliability and Risk Analysis System (IRRAS) Version 2.0 user's guide

    International Nuclear Information System (INIS)

    Russell, K.D.; Sattison, M.B.; Rasmuson, D.M.

    1990-06-01

    The Integrated Reliability and Risk Analysis System (IRRAS) is a state-of-the-art, microcomputer-based probabilistic risk assessment (PRA) model development and analysis tool to address key nuclear plant safety issues. IRRAS is an integrated software tool that gives the user the ability to create and analyze fault trees and accident sequences using a microcomputer. This program provides functions that range from graphical fault tree construction to cut set generation and quantification. Also provided in the system is an integrated full-screen editor for use when interfacing with remote mainframe computer systems. Version 1.0 of the IRRAS program was released in February of 1987. Since that time, many user comments and enhancements have been incorporated into the program providing a much more powerful and user-friendly system. This version has been designated IRRAS 2.0 and is the subject of this user's guide. Version 2.0 of IRRAS provides all of the same capabilities as Version 1.0 and adds a relational data base facility for managing the data, improved functionality, and improved algorithm performance. 9 refs., 292 figs., 4 tabs

  1. Sand and gravel mine operations and reclamation planning using microcomputers

    Energy Technology Data Exchange (ETDEWEB)

    Ariffin, J.B.

    1990-02-01

    The purpose of this study is to focus on the application of microcomputers, also known as personal computers, in planning for sand and gravel mine operations and reclamation at a site in Story County, Iowa. This site, called the Arrasmith Pit, is operated by Martin Marietta Aggregates, Inc. The Arrasmith site, which encompasses an area of about 25 acres, is a relatively small site for aggregate mining. However, planning for the concurrent mine operation and reclamation program at this site is just as critical as with larger sites and the planning process is the same.

  2. Adjunctive Steps for Disinfection of the Mandibular Molar Root Canal System: A Correlative Bacteriologic, Micro-Computed Tomography, and Cryopulverization Approach.

    Science.gov (United States)

    Alves, Flávio R F; Andrade-Junior, Carlos V; Marceliano-Alves, Marília F; Pérez, Alejandro R; Rôças, Isabela N; Versiani, Marco A; Sousa-Neto, Manoel D; Provenzano, José C; Siqueira, José F

    2016-11-01

    This study evaluated the disinfecting ability of chemomechanical preparation with rotary nickel-titanium instruments, followed by 2 distinct adjunctive procedures in the root canals of extracted mandibular molars by means of a correlative analytical approach. Twenty-two extracted mandibular molars were selected and anatomically matched between groups on the basis of micro-computed tomographic analysis. In the first phase of the experiment, root canals were contaminated with Enterococcus faecalis and subjected to chemomechanical preparation with BT RaCe instruments and 2.5% NaOCl irrigation. Then either XP-Endo Finisher instrument or passive ultrasonic irrigation was used to supplement disinfection. Micro-computed tomography was used to show whether the percentage of unprepared areas correlated to bacterial counts. In the second phase, the same teeth were contaminated once again, and the adjunctive procedures were used. Samples from the isthmus area of mesial roots and the apical 5-mm fragment of distal roots were obtained by cryopulverization. Samples taken before and after treatment steps in both phases were evaluated by quantitative polymerase chain reaction and statistically analyzed. In phase 1, preparation in both groups resulted in substantial decrease of bacterial counts (P  .05). In phase 2, both methods had significant antibacterial effects in the main canal, but none of them could predictably disinfect the isthmus/recess areas. Both XP-Endo Finisher and passive ultrasonic irrigation exhibited antibacterial effectiveness, but only the former caused a significant reduction in the bacterial counts after chemomechanical preparation. None of them were effective in predictably disinfecting the isthmus/recess areas. Copyright © 2016 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  3. Experimental image alignment system

    Science.gov (United States)

    Moyer, A. L.; Kowel, S. T.; Kornreich, P. G.

    1980-01-01

    A microcomputer-based instrument for image alignment with respect to a reference image is described which uses the DEFT sensor (Direct Electronic Fourier Transform) for image sensing and preprocessing. The instrument alignment algorithm which uses the two-dimensional Fourier transform as input is also described. It generates signals used to steer the stage carrying the test image into the correct orientation. This algorithm has computational advantages over algorithms which use image intensity data as input and is suitable for a microcomputer-based instrument since the two-dimensional Fourier transform is provided by the DEFT sensor.

  4. Moessbauer spectrometer on the base of the UNO-4096-90 storage and Electronica D3-28 microcomputer for four spectra simultaneous registering

    International Nuclear Information System (INIS)

    Romanov, E.S.; Ivojlov, N.G.

    1986-01-01

    Basic circuits of buffer storage and equpment for interfacing the UNO-4096-90 storage with the ''Ehlektronika D3-28'' microcomputer, permitting to register simultaneously four Moessbauer spectra with zero dead time, are described. To eliminate completely the dead time, pulses from each detector enter two buffer counters, operating in turn in the regimes of registering and survey. Due to such performance of buffer storage mutual effect of counters is also excluded. The use of the circuits does not require any alterations in the computer and storage device

  5. The Use of a Microcomputer in Collecting Data from Cardiovascular Experiments on Muscle Relaxants

    Science.gov (United States)

    Thut, Paul D.; Polansky, Gregg; Pruzansky, Elysa

    1983-01-01

    The possible association of cardiovascular side-effects from potentially, clinically useful non-depolarizing neuromuscular blocking drugs has been studied with the aid of a micro- computer. The maximal changes in heart rate, systolic, diastolic and mean arterial pressure and pulse pressure were recorded in the onset, maximal effect and recovery phase of relaxant activity in dogs anesthetized with isoflurane. The data collection system employed a Gould 2800S polygraph, an Apple II Plus microcomputer, a Cyborg Corp. ‘Issac’ 12 bit analog to digital converter, two 5 1/4″ floppy disk drives, a ‘Videoterm’ 80 column display board and a 12″ green phosphor monitor. Prior to development of the computer system, direct analysis of polygraph records required more than three times more time than the actual experiment. With the aid of the computer, analysis of data, tabular and graphic presentation and narrative reports were completed within 15 minutes after the end of the experiment.

  6. Development of a CCD based system called DIGITRACK for automatic track counting and evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Molnar, J.; Somogyi, G.; Szilagyi, S.; Sepsy, K. (Magyar Tudomanyos Akademia, Debrecen. Atommag Kutato Intezete)

    1984-01-01

    We have developed, to the best of our knowledge, the first automatic track analysis system (DIGITRACK) in which the video signals are processed by a new type of video-receiver called charge-coupled device (CCD). The photosensitive semi-conductor device is a 2.5 cm long line imager of type Fairchild CCD 121HC which converts one row of the picture seen through a low magnification microscope into 1728 binary signals by a thresholding logic. The picture elements are analysed by a microcomputer equipped with two INTEL 8080 microprocessors and interfaced to a PDP-11/40 computer. The microcomputer also controls the motion of the stage of microscope. For pattern recognition and analysis a software procedure is developed which is able to differentiate between overlapping tracks and to determine the number, surface opening and x-y coordinates of the tracks occurring in a given detector area. The distribution of track densities and spot areas on the detector surface can be visualized on a graphic display. The DIGITRACK system has been tested for analysis of alpha-tracks registered in CR-39 and LR-115 detectors.

  7. Control system for a superconducting rectifier using a microcomputer

    International Nuclear Information System (INIS)

    ten Kate, H.H.J.; Kamphuis, D.A.; Caspari, M.; van de Klundert, L.J.M.; Houkes, Z.

    1981-01-01

    Within the scope of a research program of superconducting rectifiers software is being developed to take care of the control of such systems. The hardware architecture which interferes with the in and output signals is based on a LSI-11/2 microprocessor with sufficient mass storage for data logging, console and printer. The flexibility inherent to this hardware configuration is desired for optimization of the rectifier concerning maximum current, power, efficiency and quench stability. The paper describes the structure of the program and the interaction between both computer hardware and software and the superconducting rectifier. However, because the reliability of computer systems is unsatisfactory, an additional hardware protection system still handles the most important alarms. 2 refs

  8. Operating experience with a new accelerator control system based upon microprocessors

    Energy Technology Data Exchange (ETDEWEB)

    Magyary, S.; Lancaster, H.; Selph, F.; Fahmie, M.; Timossi, C.; Glatz, J.; Ritchie, A.; Hinkson, J.; Benjegerdes, R.; Brodzik, D.

    1981-03-01

    This paper describes the design and operating experience with a high performance control system tailored to the requirements of the SuperHILAC accelerator. A large number (20) of the latest 16-bit microcomputer boards are used in a parallel-distributed manner to get a high system bandwidth. Because of the high bandwidth, software costs and complexity are significantly reduced. The system by its very nature and design is easily upgraded and repaired. Dynamically assigned and labeled knobs, together with touch-panels, allow a flexible and efficient operator interface. An X-Y vector graphics system provides for display and labeling of real-time signals as well as general plotting functions. This control system allows attachment of a powerful auxiliary computer for scientific processing with access to accelerator parameters.

  9. Simulator of a fail detector system for redundant sensors

    International Nuclear Information System (INIS)

    Assumpcao Filho, E.O.; Nakata, H.

    1990-01-01

    A failure detection and isolation system (FDI) simulation program has been developed for IBM-PC microcomputers. The program, based on the sequencial likelihood ratio testing method developed by A. Wald, was implemented with Monte-Carlo technique. The calculated failure detection rate was favorably compared against the wind-tunnel experimental redundant temperature sensors. (author)

  10. Technical aspects of X-ray micro-computed tomography. Initial experience of 27-μm resolution using feldkamp cone-beam reconstruction

    International Nuclear Information System (INIS)

    Yamamoto, Shuji; Suzuki, Masahiro; Kohara, Kazushi; Iinuma, Gen; Moriyama, Noriyuki

    2007-01-01

    The objective of this study was to introduce the technical utility of micro-computed tomography (CT) with 27-μm resolution by cone-beam CT algorithm. Whole-body micro-CT scans were performed to honeybee. Two- and three-dimensional image analyses were performed by originally developed and available open-source software for acquired images. The original contribution of this work is to describe the technical characteristics of the X-ray micro-CT system, keeping a small experimental insect in a unique condition. Micro-CT may be used as a rapid prototyping tool to research and understand the high-resolution system with Feldkamp cone-beam reconstruction. (author)

  11. Systems Analysis Programs for Hands-on Integrated Reliability Evaluations (SAPHIRE), Version 5.0: Integrated Reliability and Risk Analysis System (IRRAS) reference manual. Volume 2

    International Nuclear Information System (INIS)

    Russell, K.D.; Kvarfordt, K.J.; Skinner, N.L.; Wood, S.T.; Rasmuson, D.M.

    1994-07-01

    The Systems Analysis Programs for Hands-on Integrated Reliability Evaluations (SAPHIRE) refers to a set of several microcomputer programs that were developed to create and analyze probabilistic risk assessments (PRAs), primarily for nuclear power plants. The Integrated Reliability and Risk Analysis System (IRRAS) is a state-of-the-art, microcomputer-based probabilistic risk assessment (PRA) model development and analysis tool to address key nuclear plant safety issues. IRRAS is an integrated software tool that gives the use the ability to create and analyze fault trees and accident sequences using a microcomputer. This program provides functions that range from graphical fault tree construction to cut set generation and quantification to report generation. Version 1.0 of the IRRAS program was released in February of 1987. Since then, many user comments and enhancements have been incorporated into the program providing a much more powerful and user-friendly system. This version has been designated IRRAS 5.0 and is the subject of this Reference Manual. Version 5.0 of IRRAS provides the same capabilities as earlier versions and ads the ability to perform location transformations, seismic analysis, and provides enhancements to the user interface as well as improved algorithm performance. Additionally, version 5.0 contains new alphanumeric fault tree and event used for event tree rules, recovery rules, and end state partitioning

  12. Assessing apical transportation in curved canals: comparison between cross-sections and micro-computed tomography

    Directory of Open Access Journals (Sweden)

    Laila Gonzales Freire

    2012-06-01

    Full Text Available The aim of this study was to compare two methods of assessing apical transportation in curved canals after rotary instrumentation, namely, cross-sections and micro-computed tomography (µCT. Thirty mandibular molars were divided into two groups and prepared according to the requirements of each method. In G1 (cross-sections, teeth were embedded in resin blocks and sectioned at 2.0, 3.5, and 5.0 mm from the anatomic apex. Pre- and postoperative sections were photographed and analyzed. In G2 (µCT, teeth were embedded in a rubber-base impression material and scanned before and after instrumentation. Mesiobuccal canals were instrumented with the Twisted File (TF system (SybronEndo, Orange, USA, and mesiolingual canals, with the EndoSequence (ES system (Brasseler, Savannah, USA. Images were reconstructed, and sections corresponding to distances 2.0, 3.5, and 5.0 mm from the anatomic apex were selected for comparison. Data were analyzed using Mann-Whitney's test at a 5% significance level. The TF and ES instruments produced little deviation from the root canal center, with no statistical difference between them (P > 0.05. The canal transportation results were significantly lower (0.056 mm in G2 than in G1 (0.089 mm (p = 0.0012. The µCT method was superior to the cross-section method, especially in view of its ability to preserve specimens and provide results that are more closely related to clinical situations.

  13. Transportable educational programs for scientific and technical professionals: More effective utilization of automated scientific and technical data base systems

    Science.gov (United States)

    Dominick, Wayne D.

    1987-01-01

    This grant final report executive summary documents a major, long-term program addressing innovative educational issues associated with the development, administration, evaluation, and widespread distribution of transportable educational programs for scientists and engineers to increase their knowledge of, and facilitate their utilization of automated scientific and technical information storage and retrieval systems. This educational program is of very broad scope, being targeted at Colleges of Engineering and Colleges of Physical sciences at a large number of colleges and universities throughout the United States. The educational program is designed to incorporate extensive hands-on, interactive usage of the NASA RECON system and is supported by a number of microcomputer-based software systems to facilitate the delivery and usage of the educational course materials developed as part of the program.

  14. Integrated Reliability and Risk Analysis System (IRRAS), Version 2.5: Reference manual

    International Nuclear Information System (INIS)

    Russell, K.D.; McKay, M.K.; Sattison, M.B.; Skinner, N.L.; Wood, S.T.; Rasmuson, D.M.

    1991-03-01

    The Integrated Reliability and Risk Analysis System (IRRAS) is a state-of-the-art, microcomputer-based probabilistic risk assessment (PRA) model development and analysis tool to address key nuclear plant safety issues. IRRAS is an integrated software tool that gives the user the ability to create and analyze fault trees and accident sequences using a microcomputer. This program provides functions that range from graphical fault tree construction to cut set generation and quantification. Version 1.0 of the IRRAS program was released in February of 1987. Since that time, many user comments and enhancements have been incorporated into the program providing a much more powerful and user-friendly system. This version has been designated IRRAS 2.5 and is the subject of this Reference Manual. Version 2.5 of IRRAS provides the same capabilities as Version 1.0 and adds a relational data base facility for managing the data, improved functionality, and improved algorithm performance. 7 refs., 348 figs

  15. [A wireless smart home system based on brain-computer interface of steady state visual evoked potential].

    Science.gov (United States)

    Zhao, Li; Xing, Xiao; Guo, Xuhong; Liu, Zehua; He, Yang

    2014-10-01

    Brain-computer interface (BCI) system is a system that achieves communication and control among humans and computers and other electronic equipment with the electroencephalogram (EEG) signals. This paper describes the working theory of the wireless smart home system based on the BCI technology. We started to get the steady-state visual evoked potential (SSVEP) using the single chip microcomputer and the visual stimulation which composed by LED lamp to stimulate human eyes. Then, through building the power spectral transformation on the LabVIEW platform, we processed timely those EEG signals under different frequency stimulation so as to transfer them to different instructions. Those instructions could be received by the wireless transceiver equipment to control the household appliances and to achieve the intelligent control towards the specified devices. The experimental results showed that the correct rate for the 10 subjects reached 100%, and the control time of average single device was 4 seconds, thus this design could totally achieve the original purpose of smart home system.

  16. Microcomputer-based instrument for the detection and analysis of precession motion in a gas centrifuge machine

    International Nuclear Information System (INIS)

    Paulus, S.S.

    1986-03-01

    The Centrifuge Precession Analyzer (CPA) is a microcomputer-based instrument which detects precession motion in a gas centrifuge machine and calculates the amplitude and frequency of precession. The CPA consists of a printed circuit board which contains signal-conditioning circuitry and a 24-bit counter and an INTEL iSBC 80-/24 single-board computer. Precession motion is detected by monitoring a signal generated by a variable reluctance pick-up coil in the top of the centrifuge machine. This signal is called a Fidler signal. The initial Fidler signal triggers a counter which is clocked by a high-precision, 20.000000-MHz, temperature-controlled, crystal oscillator. The contents of the counter are read by the computer, and the counter reset after every ten Fidler signals. The speed of the centrifuge machine and the amplitude and frequency of precession are calculated, and the results are displayed on a liquid crystal display on the front panel of the CPA. The thesis contains results from data generated by a Fidler signal simulator and data taken when the centrifuge was operated under three test conditions: (1) nitrogen gas during drive-up, steady state, and drive-down, (2) xenon gas during slip test, steady state, and the addition of gas, and (3) no gas during steady state. The qualitative results were consistent with experience with centrifuge machines UF 6 in that the amplitude of precession increased and the frequency of precession decreased during drive-up, drive-down and the slip check. The magnitude of the amplitude and frequency of precession were proportional to the molecular weight of the gases in steady state

  17. Effect of micro-computed tomography voxel size and segmentation method on trabecular bone microstructure measures in mice

    Directory of Open Access Journals (Sweden)

    Blaine A. Christiansen

    2016-12-01

    Full Text Available Micro-computed tomography (μCT is currently the gold standard for determining trabecular bone microstructure in small animal models. Numerous parameters associated with scanning and evaluation of μCT scans can strongly affect morphologic results obtained from bone samples. However, the effect of these parameters on specific trabecular bone outcomes is not well understood. This study investigated the effect of μCT scanning with nominal voxel sizes between 6–30 μm on trabecular bone outcomes quantified in mouse vertebral body trabecular bone. Additionally, two methods for determining a global segmentation threshold were compared: based on qualitative assessment of 2D images, or based on quantitative assessment of image histograms. It was found that nominal voxel size had a strong effect on several commonly reported trabecular bone parameters, in particular connectivity density, trabecular thickness, and bone tissue mineral density. Additionally, the two segmentation methods provided similar trabecular bone outcomes for scans with small nominal voxel sizes, but considerably different outcomes for scans with larger voxel sizes. The Qualitatively Selected segmentation method more consistently estimated trabecular bone volume fraction (BV/TV and trabecular thickness across different voxel sizes, but the Histogram segmentation method more consistently estimated trabecular number, trabecular separation, and structure model index. Altogether, these results suggest that high-resolution scans be used whenever possible to provide the most accurate estimation of trabecular bone microstructure, and that the limitations of accurately determining trabecular bone outcomes should be considered when selecting scan parameters and making conclusions about inter-group variance or between-group differences in studies of trabecular bone microstructure in small animals. Keywords: Trabecular bone, Microstructure, Micro-computed tomography, Voxel size, Resolution

  18. 1024-65536 channel nuclear spectrum data acquisition and processing system

    Energy Technology Data Exchange (ETDEWEB)

    Songjiang, Xia

    1987-09-01

    A multiscale data acquisition and processing system based on IBM PC/XT microcomputer is described. In this system, not only 1024,2048,4096 single parameter spectrum, but also 128 x 128, 256 x 256 dual parameter spectrum can be acquisited. The interface logic is designed to work at sequential recording DMA mode, the total avergage time for recording each descriptor is 7.5 ..mu..s.

  19. Microcomputer-assisted determination of local blood flow by 133Xe

    International Nuclear Information System (INIS)

    Hoffschir, D.; Fayart, G.; Daburon, F.

    1990-02-01

    Acute local irradiations may induce extensive and delayed cutaneous and muscular ulcerations. We intended to study the prevalence of vascular factors in their pathogeny in an experimental model developed in pigs. Local clearance curves were assessed after intra-arterial administration of 133 Xe and transferred to a micro-computer. A program for poly-exponential curve fitting, written in Asyst langage, has been developed. An iterative curve stripping is performed conventionally and then the coefficients are more precisely determined using a Gauss-Newton method. This program has been tested on experimental data obtained after a 40 Gy local over-exposure [fr

  20. Microcomputer-controlled thermoluminescent analyser IJS MR-200

    International Nuclear Information System (INIS)

    Mihelic, M.; Miklavzic, U.; Rupnik, Z.; Satalic, P.; Spreizer, F.; Zerovnik, I.

    1985-01-01

    Performances and concept of the multipurpose, microcomputer-controlled thermoluminescent analyser, designed for use in laboratory work TL dosemeters as well as for routine dose readings in the range from ecological to accident doses is described. The main features of the analyser are: time-linear sampling, digitalisation, storing, and subsequent displaying on the monitor time scale of the glow and and temperature curve of the TL material; digital stabilization, control and diagnostic of the analog unit; ability of storing 7 different 8-parametric heating programs; ability of storing 15 evaluation programs defined by 2 or 4 parameters and 3 different algorithms (altogether 5 types of evaluations). Analyser has several features intended for routine work: 9 function keys and possibilities of file forming on cassette or display disc, of dose calculation and averaging, of printing reports with names, and possibility of additional programming in Basic. (author)

  1. A program to operate the TSI electrical aerosol analyser using an IBM-PC microcomputer - technical background

    International Nuclear Information System (INIS)

    Horton, K.D.; Mitchell, J.P.; Snelling, K.W.

    1988-02-01

    A program has been written to enable the TSI Electrical Aerosol Analyser (EAA model 3030) to be operated using an IBM-PC microcomputer. Although much of the program is based on the software supplied by TSI Inc to collect and process data from the EAA, it incorporates numerous improvements including the option to operate the EAA automatically via a TSI Differential Mobility Particle Sizer interface. When compiled, the program enables the data reduction which takes into account the significant cross-channel sensitivity of the EAA, to be performed in about 30 seconds making it possible to use the EAA to monitor rapid changes in the behaviour of sub-micron aerosol particles. (author)

  2. Comparison of digital intraoral scanners by single-image capture system and full-color movie system.

    Science.gov (United States)

    Yamamoto, Meguru; Kataoka, Yu; Manabe, Atsufumi

    2017-01-01

    The use of dental computer-aided design/computer-aided manufacturing (CAD/CAM) restoration is rapidly increasing. This study was performed to evaluate the marginal and internal cement thickness and the adhesive gap of internal cavities comprising CAD/CAM materials using two digital impression acquisition methods and micro-computed tomography. Images obtained by a single-image acquisition system (Bluecam Ver. 4.0) and a full-color video acquisition system (Omnicam Ver. 4.2) were divided into the BL and OM groups, respectively. Silicone impressions were prepared from an ISO-standard metal mold, and CEREC Stone BC and New Fuji Rock IMP were used to create working models (n=20) in the BL and OM groups (n=10 per group), respectively. Individual inlays were designed in a conventional manner using designated software, and all restorations were prepared using CEREC inLab MC XL. These were assembled with the corresponding working models used for measurement, and the level of fit was examined by three-dimensional analysis based on micro-computed tomography. Significant differences in the marginal and internal cement thickness and adhesive gap spacing were found between the OM and BL groups. The full-color movie capture system appears to be a more optimal restoration system than the single-image capture system.

  3. Commutated automatic gain control system

    Science.gov (United States)

    Yost, S. R.

    1982-01-01

    A commutated automatic gain control (AGC) system was designed and built for a prototype Loran C receiver. The receiver uses a microcomputer to control a memory aided phase-locked loop (MAPLL). The microcomputer also controls the input/output, latitude/longitude conversion, and the recently added AGC system. The circuit designed for the AGC is described, and bench and flight test results are presented. The AGC circuit described actually samples starting at a point 40 microseconds after a zero crossing determined by the software lock pulse ultimately generated by a 30 microsecond delay and add network in the receiver front end envelope detector.

  4. Development of the 'JFT-2' tokamak plasma position control system

    International Nuclear Information System (INIS)

    Fujisawa, Noboru; Matsuzaki, Yoshimi; Suzuki, Norio; Murai, Katsuji; Suzuki, Satoshi.

    1980-01-01

    Digital control technique was applied to control the plasma position in the JFT-2 tokamak experiment device. The detail of the JFT-2 is described elsewhere. The plasma position control system consists of a Hitachi control computer, HIDIC 80, and a Hitachi micro-computer, HIDIC 08E. The plasma position is detected by the position control computer, and compared with a preset value. Then, a reference signal is supplied to the micro-computer controlling power source, and the phase control of the thyristor controlling power source is performed. Since the behavior of plasma is very fast, the fast control is required. The control of the thyristor controlling power source is made by direct digital control (DDC). The main component of the hardware of the present system is the micro-computer HIDIC 08E. The software is the direct task system without the operating system (OS). The results of experiments showed that the feedback control of the system worked well. (Kato, T.)

  5. The computer-based control system of the NAC accelerator

    International Nuclear Information System (INIS)

    Burdzik, G.F.; Bouckaert, R.F.A.; Cloete, I.; Du Toit, J.S.; Kohler, I.H.; Truter, J.N.J.; Visser, K.

    1982-01-01

    The National Accelerator Centre (NAC) of the CSIR is building a two-stage accelerator which will provide charged-particle beams for the use in medical and research applications. The control system for this accelerator is based on three mini-computers and a CAMAC interfacing network. Closed-loop control is being relegated to the various subsystems of the accelerators, and the computers and CAMAC network will be used in the first instance for data transfer, monitoring and servicing of the control consoles. The processing power of the computers will be utilized for automating start-up and beam-change procedures, for providing flexible and convenient information at the control consoles, for fault diagnosis and for beam-optimizing procedures. Tasks of a localized or dedicated nature are being off-loaded onto microcomputers, which are being used either in front-end devices or as slaves to the mini-computers. On the control consoles only a few instruments for setting and monitoring variables are being provided, but these instruments are universally-linkable to any appropriate machine variable

  6. The new control system of the Saclay linear accelerator

    International Nuclear Information System (INIS)

    Gournay, J.F.; Gourcy, G.; Garreau, F.; Giraud, A.; Rouault, J.

    1985-05-01

    A new control system for the Safety Linear Accelerator is now being designed. The computer control architecture is based on 3 dedicated VME crates with MC68000 micro-processors: one crate with a disk-based operating system will run the high level application programs and the data base management facilities, another one will manage the man-machine communications and the third one will interface the system to the linac equipments. Communications between the VME microcomputers will be done through 16 bit parallel links. The software is modular and organized in specific layers, the data base is fully distributed. About 90% of the code is written in Fortran

  7. A microprocessor based area monitor system for neutron and gamma radiation

    International Nuclear Information System (INIS)

    Wilhelm, R.; Heusser, G.

    1980-01-01

    The conventional electronics of the area monitors at the MPI-Heidelberg accelerators have been replaced by a microprocessor system consisting of individual detector-microprocessors and a central microcomputer. The detector microprocessors convert the count rates of BF3 and GM counter tubes into dose rates and control three different radiation thresholds (failure, low and high level). Different warning signals are operated directly by the detector processors, whereas the dose rates are transferred to the central microcomputer. Here the data are processed for recording on tape and displaying on TV monitors. The detector as well as the central processors have been developed on the basis of a 16-bit microprocessor. In the control rooms the dose rates of the individual monitors are displayed and on an indicator board showing the different locations, the high radiation level and the state of the doors (open, locked, and closed, locked but open) are sianaled by different LED. If a high radiation threshold is surpassed, the doors adjacent to that area can be locked either by switches on the indicator board or automatically. Within the experimental area, the low and high radiation level is indicated by acoustic and light signals. The whole concept permits keeping the absorbed doses of the personnel as low as possible without affecting the flexibility of the experimental operations. The independence of the microprocessor driven area monitors guarantees a high reliability. Compared to conventional electronics the advantages of the system are its reliability and cost. (Author)

  8. EDEF: a program for solving the neutron diffusion equation using microcomputers

    International Nuclear Information System (INIS)

    Fernandes, A.; Maiorino, J.R.

    1990-01-01

    This work presents the development of a program to solve the two-group two-dimensional diffusion equation (with a buckling option to simulate axial leakage) applying the finite element method. It has been developed to microcomputers compatibles to the IBM-PC. Among the facilities of the program, we can mention the simplicity to represent two-dimensional complex domains, the input through a pre-processor and the output in which the fluxes are presented graphically. The program also calculates the multiplication factor, the peaking factor and the power distribution. (author) [pt

  9. Portable microcomputer unit for the analysis of plutonium gamma-ray spectra

    International Nuclear Information System (INIS)

    Ruhter, W.D.; Camp, D.C.

    1981-10-01

    A portable microcomputer has been developed for the IAEA to perform in-field analysis of plutonium gamma-ray spectra. The unit includes a 16-bit LSI-11/2 microprocessor, 32K words of memory, a 20-character display for user prompting, and a 20-character thermal printer for hardcopy output. Only the positions of the 148-keV Pu-241 and 208-keV U-237 peaks are required for spectral analysis. The unit was tested against gamma-ray spectra taken of NBS plutonium standards and IAEA spectra. Results obtained are presented

  10. In vivo quantitative assessment of myocardial structure, function, perfusion and viability using cardiac micro-computed tomography

    NARCIS (Netherlands)

    E.D. van Deel (Elza); Y. Ridwan (Yanto); van Vliet, J.N. (J. Nicole); Belenkov, S. (Sasha); J. Essers (Jeroen)

    2016-01-01

    textabstractThe use of Micro-Computed Tomography (MicroCT) for in vivo studies of small animals as models of human disease has risen tremendously due to the fact that MicroCT provides quantitative high-resolution three-dimensional (3D) anatomical data non-destructively and longitudinally. Most

  11. An Ibm PC/AT-Based Image Acquisition And Processing System For Quantitative Image Analysis

    Science.gov (United States)

    Kim, Yongmin; Alexander, Thomas

    1986-06-01

    In recent years, a large number of applications have been developed for image processing systems in the area of biological imaging. We have already finished the development of a dedicated microcomputer-based image processing and analysis system for quantitative microscopy. The system's primary function has been to facilitate and ultimately automate quantitative image analysis tasks such as the measurement of cellular DNA contents. We have recognized from this development experience, and interaction with system users, biologists and technicians, that the increasingly widespread use of image processing systems, and the development and application of new techniques for utilizing the capabilities of such systems, would generate a need for some kind of inexpensive general purpose image acquisition and processing system specially tailored for the needs of the medical community. We are currently engaged in the development and testing of hardware and software for a fairly high-performance image processing computer system based on a popular personal computer. In this paper, we describe the design and development of this system. Biological image processing computer systems have now reached a level of hardware and software refinement where they could become convenient image analysis tools for biologists. The development of a general purpose image processing system for quantitative image analysis that is inexpensive, flexible, and easy-to-use represents a significant step towards making the microscopic digital image processing techniques more widely applicable not only in a research environment as a biologist's workstation, but also in clinical environments as a diagnostic tool.

  12. System Analysis and Risk Assessment System (SARA), Version 4.0

    International Nuclear Information System (INIS)

    Russell, K.D.; Sattison, M.B.; Skinner, N.L.; Stewart, H.D.; Wood, S.T.

    1992-02-01

    This NUREG is the reference manual for the System Analysis and Risk Assessment (SARA) System Version 4.0, a microcomputer-based system used to analyze the safety issues of a family [i.e., a power plant, a manufacturing facility, any facility on which a probabilistic risk assessment (PRA) might be performed]. The SARA data base contains PRA data for the dominant accident sequences of a family and descriptive information about the family including event trees, fault trees, and system model diagrams. The number of facility data bases that can be accessed is limited only by the amount of disk storage available. To simulate changes to family systems, SARA users change the failure rates of initiating and basic events and/or modify the structure of the cut sets that make up the event trees, fault trees, and systems. The user then evaluates the effects of these changes through the recalculation of the resultant accident sequence probabilities and importance measures. The results are displayed in tables and graphs

  13. [Analog gamma camera digitalization computer system].

    Science.gov (United States)

    Rojas, G M; Quintana, J C; Jer, J; Astudillo, S; Arenas, L; Araya, H

    2004-01-01

    Digitalization of analogue gamma cameras systems, using special acquisition boards in microcomputers and appropriate software for acquisition and processing of nuclear medicine images is described in detail. Microcomputer integrated systems interconnected by means of a Local Area Network (LAN) and connected to several gamma cameras have been implemented using specialized acquisition boards. The PIP software (Portable Image Processing) was installed on each microcomputer to acquire and preprocess the nuclear medicine images. A specialized image processing software has been designed and developed for these purposes. This software allows processing of each nuclear medicine exam, in a semiautomatic procedure, and recording of the results on radiological films. . A stable, flexible and inexpensive system which makes it possible to digitize, visualize, process, and print nuclear medicine images obtained from analogue gamma cameras was implemented in the Nuclear Medicine Division. Such a system yields higher quality images than those obtained with analogue cameras while keeping operating costs considerably lower (filming: 24.6%, fixing 48.2% and developing 26%.) Analogue gamma camera systems can be digitalized economically. This system makes it possible to obtain optimal clinical quality nuclear medicine images, to increase the acquisition and processing efficiency, and to reduce the steps involved in each exam.

  14. Microcomputer Materials from MEP. An Annotated Directory of Packages of Interest to Further Education. An Occasional Paper.

    Science.gov (United States)

    Gilbert, Leslie

    Designed to disseminate information to the post-school sector of United Kingdom education, this directory provides information on 50 microcomputer software packages developed by the Microelectronics Education Program (MEP) and available through educational publishers. Subject areas represented include accountancy, biology, business education,…

  15. A generic, geometric cocalibration method for a combined system of fluorescence molecular tomography and microcomputed tomography with arbitrarily shaped objects

    International Nuclear Information System (INIS)

    Fu Jianwei; Yang Xiaoquan; Wang Kan; Luo Qingming; Gong Hui

    2011-01-01

    Purpose: A combined system of fluorescence molecular tomography and microcomputed tomography (FMT and mCT) can provide molecular and anatomical information of small animals in a single study with intrinsically coregistered images. The anatomical information provided by the mCT subsystem is commonly used as a reference to locate the fluorophore distribution or as a priori structural information to improve the performance of FMT. Therefore, the transformation between the coordinate systems of the subsystem needs to be determined in advanced. Methods: A cocalibration method for the combined system of FMT and mCT is proposed. First, linear models are adopted to describe the galvano mirrors and the charge-coupled device (CCD) camera in the FMT subsystem. Second, the position and orientation of the galvano mirrors are determined with the input voltages of the galvano mirrors and the markers, whose positions are predetermined. The position, orientation and normalized pixel size of the CCD camera are obtained by analysing the projections of a point-like marker at different positions. Finally, the orientation and position of sources and the corresponding relationship between the detectors and their projections on the image plane are predicted. Because the positions of the markers are acquired with mCT, the registration of the FMT and mCT could be realized by direct image fusion. Results: The accuracy and consistency of this method in the presence of noise is evaluated by computer simulation. Next, a practical implementation for an experimental FMT and mCT system is carried out and validated. The maximum prediction error of the source positions on the surface of a cylindrical phantom is within 0.375 mm and that of the projections of a point-like marker is within 0.629 pixel. Finally, imaging experiments of the fluorophore distribution in a cylindrical phantom and a phantom with a complex shape demonstrate the feasibility of the proposed method. Conclusions: This method is

  16. A new bed-exiting alarm system for welfare facility residents.

    Science.gov (United States)

    Ogawa, Hidekuni; Yonezawa, Yoshiharu; Maki, Hiromichi; Caldwell, W

    2009-01-01

    A newly developed alarm system detects welfare facility residents leaving their beds, and does not respond to the care staff, who wear shoes or slippers. It employs a stainless steel tape electrode, several linear integrated circuits and a low-power 8-bit single chip microcomputer. The electrode, which is used as a bed-exiting detection sensor, is attached to the floor mat to record changes in the always-present AC (alternating current) voltage induced on the patient's body by electrostatic coupling from the standard 100 volt, 60 Hz AC utility power wiring in the room walls and ceiling. The resident's body movements, before trying to get out of bed and after leaving the bed, are detected by the microcomputer from changes in the induced AC voltage. The microcomputer alerts the care staff station, via a power line communication system or PHS (personal handy phone System).

  17. Bridge between control science and technology. Volume 5 Manufacturing man-machine systems, computers, components, traffic control, space applications

    Energy Technology Data Exchange (ETDEWEB)

    Rembold, U; Kempf, K G; Towill, D R; Johannsen, G; Paul, M

    1985-01-01

    Among the topics discussed are: robotics; CAD/CAM applications; and man-machine systems. Consideration is also given to: tools and software for system design and integration; communication systems for real-time computer control; fail-safe design of real-time computer systems; and microcomputer-based control systems. Additional topics discussed include: programmable and intelligent components and instruments in automatic control; transportation systems; and space applications of automatic control systems.

  18. A modular multi-microcomputer system for on-line vibration diagnostics

    International Nuclear Information System (INIS)

    Saedtler, E.

    1988-01-01

    A new modular multi-microprocessor system for on-line vibration monitoring and diagnostics of PWRs is described. The aim of the system is to make feasible an early detection of increasing failures in relevant regions of a reactor plant, to verify the mechanical integrity of the investigated components, and to improve therefore the operational safety of the plant. After a discussion of the implemented surveillance methods and algorithms, which are based on hierarchical structured identification (estimation) and statistical pattern recognition tools, the system architecture (software and hardware) is portrayed. The classification scheme itself works sequential so that samples (or features) can arrive on-line. This on-line classification is important in order to take necessary actions in time. Furthermore, the system has learning capabilities, which means it is adaptable to different, varying states and plant conditions. The main features of the system are presented and its contribution to an automation of complex surveillance and monitoring tasks is shown. (author)

  19. Evaluation of marginal and internal adaptation of hybrid and nanoceramic systems with microcomputed tomography: An in vitro study.

    Science.gov (United States)

    Yildirim, Güler; Uzun, Ismail H; Keles, Ali

    2017-08-01

    The accuracy of recently introduced chairside computer-aided design and computer-aided manufacturing (CAD-CAM) blocks is not well established, and marginal integrity and internal adaptation are not known. The purpose of this in vitro study was to evaluate the marginal and internal adaptation of hybrid and nanoceramics using microcomputed tomography (μ-CT). The marginal and internal adaptation of 3 polymer-infiltrated ceramic-network (PICN) materials (Vita Enamic [VE]; Lava Ultimate [LU]; Vita Suprinity [VS]) were compared with lithium disilicate (IPS e.max.CAD, IPS). Ninety-six specimens (48 dies and 48 crowns) were prepared (n=12 each group) using a chairside CAD-CAM system. The restorations were scanned with μ-CT, with 160 measurements made for each crown, and used in 2-dimensional (2D) analysis. The marginal adaptation of marginal discrepancy (MD), absolute marginal discrepancy (AMD), internal adaptation of shoulder area (SA), axial space (AS), and occlusal space (OS) were compared using appropriate statistical analysis methods (α=.05). Cement volumes were compared using 3D analysis. The IPS blocks showed higher MD (130 μm), AMD (156 μm), SA (111 μm) (P.05). IPS had the largest cement space at 18 mm 3 (Pmarginal and internal adaptation values were within a clinically acceptable range for all 3 hybrids and nanoceramics tested. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  20. Evaluation of the Self-Adjusting File system (SAF) for the instrumentation of primary molar root canals: a micro-computed tomographic study.

    Science.gov (United States)

    Kaya, E; Elbay, M; Yiğit, D

    2017-06-01

    The Self-Adjusting File (SAF) system has been recommended for use in permanent teeth since it offers more conservative and effective root-canal preparation when compared to traditional rotary systems. However, no study had evaluated the usage of SAF in primary teeth. The aim of this study was to evaluate and compare the use of SAF, K file (manual instrumentation) and Profile (traditional rotary instrumentation) systems for primary-tooth root-canal preparation in terms of instrumentation time and amounts of dentin removed using micro-computed tomography (μCT) technology. Study Design: The study was conducted with 60 human primary mandibular second molar teeth divided into 3 groups according to instrumentation technique: Group I: SAF (n=20); Group II: K file (n=20); Group III; Profile (n=20). Teeth were embedded in acrylic blocks and scanned with a μCT scanner prior to instrumentation. All distal root canals were prepared up to size 30 for K file,.04/30 for Profile and 2 mm thickness, size 25 for SAF; instrumentation time was recorded for each tooth, and a second μCT scan was performed after instrumentation was complete. Amounts of dentin removed were measured using the three-dimensional images by calculating the difference in root-canal volume before and after preparation. Data was statistically analysed using the Kolmogorov-Smirnov and Kruskal-Wallis tests. Manual instrumentation (K file) resulted in significantly more dentin removal when compared to rotary instrumentation (Profile and SAF), while the SAF system generated significantly less dentin removal than both manual instrumentation (K file) and traditional rotary instrumentation (Profile) (psystems. Within the experimental conditions of the present study, the SAF seems as a useful system for root-canal instrumentation in primary molars because it removed less dentin than other systems, which is especially important for the relatively thin-walled canals of primary teeth, and because it involves less

  1. Preexisting Dentinal Microcracks in Nonendodontically Treated Teeth: An Ex Vivo Micro-computed Tomographic Analysis.

    Science.gov (United States)

    PradeepKumar, Angambakkam Rajasekaran; Shemesh, Hagay; Chang, Jeffrey Wen-Wei; Bhowmik, Ahendita; Sibi, Swamy; Gopikrishna, Velayutham; Lakshmi-Narayanan, Lakshmikanthanbharathi; Kishen, Anil

    2017-06-01

    This study evaluated the prevalence, location, and pattern of preexisting dentinal microcracks in roots of extracted teeth without endodontic treatment in patients from 2 age groups using micro-computed tomographic imaging. Six hundred thirty-three nonendodontically treated teeth extracted using an atraumatic procedure because of reasons unrelated to this study were collected and divided based on the patient age. Teeth were scanned with micro-computed tomographic imaging (resolution of 26.7 μm) to examine the presence of preexisting dentinal microcracks in roots. The characteristic features of preexisting dentinal microcracks determined were location, extent, length, and coronoapical distribution. Chi-square bivariate analysis was performed to assess the association between various parameters. Forty-five of 633 nonendodontically treated teeth exhibited preexisting microcracks in roots with a prevalence of 7.1%. The prevalence of preexisting microcracks was found to be 8.3% in older patients (40-70 years) compared with 3.7% in younger patients (20-39 years) (P < .050). A significant association was found between the preexisting microcracks in mandibular teeth (10.3%) when compared with maxillary teeth (2.9%) (P < .001). All preexisting microcracks were located mesiodistally; 66% occurred in the cervical and middle thirds of root. Only 33% of the preexisting microcracks were complete in nature, showing canal involvement. Complete dentinal microcracks exhibited a mean length of 6.9 mm, whereas incomplete cracks had a mean length of 3.75 mm (P < .001). Preexisting dentinal microcracks in roots of nonendodontically treated teeth occurred more often in older patients (40-70 years) in the mesiodistal direction. They were predominantly found in the cervical and middle thirds of root and were more likely to be incomplete in nature. Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  2. ATROPOS: a versatile data acquisition and analysis system

    International Nuclear Information System (INIS)

    Logg, C.A.; Cottrell, R.L.A.

    1978-10-01

    Versatile, portable, rugged, and compact test and control modules for use in the development and testing of detection equipment for high-energy physics experiments are frequently needed at SLAC. The basic system developed is based on an LSI-11 microcomputer with 24K RAM, 4K ROM, 2 serial interfaces (one to the console terminal, the other to the large SLAC IBM computer complex (the TRIPLEX)), a programable clock, and a CAMAC crate controller. Data logging support is provided for magnetic tape, floppy disk, and an interactive program (ACQUIRE) which runs on the TRIPLEX under the timesharing system ORVYL. Data are read from various CAMAC modules, collected, buffered, and optionally logged. At a lower priority, the data read are sampled and analyzed in real-time on the LSI-11 to produce various histograms and tables. Concurrently, a more extensive analysis can be performed by the TRIPLEX program on the data which are logged to it. Interactive facilities provided by the microcomputer operating system enable the user to change CAMAC module addresses and the function codes used with them, specify various data cuts and transformations that are to be performed on the sample data, and specify new histogram limits and titles. Results of the real-time analysis, by both the microcomputer and the TRIPLEX program (if it is attached), may be displayed in graphical or tabular form on the console terminal. The basic system hardware cost (exclusive of the magnetic tape drive and floppy disk drive) is around $7000. The software is written in a modular fashion so that the user can supply his own data reading and analysis routines. This system has been in use for two years by various groups on several LSI-11s at SLAC. 3 figures

  3. Application of micro-computed tomography to microstructure studies of the medicinal fungus Hericium coralloides.

    Science.gov (United States)

    Pallua, Johannes D; Kuhn, Volker; Pallua, Anton F; Pfaller, Kristian; Pallua, Anton K; Recheis, Wolfgang; Pöder, Reinhold

    2015-01-01

    The potential of 3-D nondestructive imaging techniques such as micro-computed tomography (micro-CT) was evaluated to study morphological patterns of the potential medicinal fungus Hericium coralloides (Basidiomycota). Micro-CT results were correlated with histological information gained from scanning electron microscopy (SEM) and light microscopy (LM). It is demonstrated that the combination of these imaging methods results in a more distinct picture of the morphology of the edible and potentially medicinal Hericium coralloides basidiomata. In addition we have created 3-D reconstructions and visualizations based on micro-CT imagery from a randomly selected part of the upper region of a fresh H. coralloides basidioma: Analyses for the first time allowed an approximation of the evolutionary effectiveness of this bizarrely formed basidioma type in terms of the investment of tissue biomass and its reproductive output (production of basidiospores). © 2015 by The Mycological Society of America.

  4. Multi-channel data acquisition and processing system for moessbauer spectroscopy

    International Nuclear Information System (INIS)

    Jin Ge; Yang Yanming

    1987-01-01

    A multi-channel data acquisition and processing system for moessbauer spectroscopy is described, which consists of an intelligent interface and a BC3-80 microcomputer. The system has eight data channels, each channel contains a counting circuit and a memory. A Z80-CPU is used as a main unit for control and access. The microcomputer is used for real-time displaying spectrum, saving the data to disk, printing data and data processing. The system is applicable to a high counting rate multi-wire proportional chamber. It can increase greatly the counting rate for measuring moessbauer spectrum. The signals of each wire in the chamber go through a corresponding amplifier and a differential discriminator and are recorded by a corresponding data channel, the data of each channel is added by the microcomputer. In addition, two channels can be used to measure an absorption and a scattering spectrum at the same time and the internal and the surface information of the sample are obtained simultaneously

  5. Hand and nickel-titanium root canal instrumentation performed by dental students: a micro-computed tomographic study.

    Science.gov (United States)

    Peru, M; Peru, C; Mannocci, F; Sherriff, M; Buchanan, L S; Pitt Ford, T R

    2006-02-01

    The aim of this study was to evaluate root canals instrumented by dental students using the modified double-flared technique, nickel-titanium (NiTi) rotary System GT files and NiTi rotary ProTaper files by micro-computed tomography (MCT). A total of 36 root canals from 18 mesial roots of mandibular molar teeth were prepared; 12 canals were prepared with the modified double-flared technique, using K-flexofiles and Gates-Glidden burs; 12 canals were prepared using System GT and 12 using ProTaper rotary files. Each root was scanned using MCT preoperatively and postoperatively. At the coronal and mid-root sections, System GT and ProTaper files produced significantly less enlarged canal cross-sectional area, volume and perimeter than the modified double-flared technique (P ProTaper (P ProTaper and System GT were able to prepare root canals with little or no procedural error compared with the modified double-flared technique. Under the conditions of this study, inexperienced dental students were able to prepare curved root canals with rotary files with greater preservation of tooth structure, low risk of procedural errors and much quicker than with hand instruments.

  6. Design of mini-multi-gas monitoring system based on IR absorption

    Energy Technology Data Exchange (ETDEWEB)

    Tan, Q.L.; Zhang, W.D.; Xue, C.Y.; Xiong, J.J.; Ma, Y.C.; Wen, F. [Northern University of China, Taiyuan (China)

    2008-07-15

    In this paper, a novel non-dispersive infrared ray (IR) gas detection system is described. Conventional devices typically include several primary components: a broadband source (usually all incandescent filament), a rotating chopper shutter, a narrow-band filter, a sample tube and a detector. But we mainly use file mini-multi-channel detector, electrical modulation means and mini-gas-cell structure. To solve the problems of gas accidents in coal mines, and for family safety that results from using gas, this new IR detection system with integration, miniaturization and non-moving parts has been developed. It is based on the principle that certain gases absorb infrared radiation at specific (and often unique) wavelengths. The infrared detection optics principle used in developing this system is mainly analyzed. The idea of multi-gas detection is introduced and guided through the analysis of the single-gas detection. Through researching the design of cell structure, a cell with integration and miniaturization has been devised. By taking a single-chip microcomputer (SCM) as intelligence handling, the functional block diagram of a gas detection system is designed with the analyzing and devising of its hardware and software system. The way of data transmission on a controller area network (CAN) bus and wireless data transmission mode is explained. This system has reached the technology requirement of lower power consumption, mini-volume, wide measure range, and is able to realize multi-gas detection.

  7. Experience of developing an integrated nondestructive assay system

    International Nuclear Information System (INIS)

    Hsue, S.T.; Baker, M.P.

    1987-01-01

    A consortium of laboratories is collaborating with the Savannah River Plant to develop an integrated system of state-of-the-art nondestructive assay (NDA) instrumentation to provide nuclear materials accounting and process control information for a new plutonium scrap recovery facility. Individual instruments report assay results to an instrument control computer (ICC); the ICC, in turn, is part of a larger computer network that includes computers that perform process control and materials accounting functions. The design of the integrated NDA measurement system is shown. Each NDA instrument that is part of the integrated system is microcomputer-based and thus is capable of stand-alone operation if the central computer is out of service. Certain hardware features, such as microcomputers, pulse processing modules, and multichannel analyzers, are standardized throughout the system. Another standard feature is the communication between individual NDA instruments and the ICC. The most unique phase of the project is the integral staging. The primary purpose of this phase is to check the communications between various computers and to verify the ICC software during the operation of the NDA instruments. Implementing this integrated system in a process environment represents a major step in realizing the full capabilities of modern NDA instrumentation

  8. Synchrotron-radiation-based X-ray micro-computed tomography reveals dental bur debris under dental composite restorations.

    Science.gov (United States)

    Hedayat, Assem; Nagy, Nicole; Packota, Garnet; Monteith, Judy; Allen, Darcy; Wysokinski, Tomasz; Zhu, Ning

    2016-05-01

    Dental burs are used extensively in dentistry to mechanically prepare tooth structures for restorations (fillings), yet little has been reported on the bur debris left behind in the teeth, and whether it poses potential health risks to patients. Here it is aimed to image dental bur debris under dental fillings, and allude to the potential health hazards that can be caused by this debris when left in direct contact with the biological surroundings, specifically when the debris is made of a non-biocompatible material. Non-destructive micro-computed tomography using the BioMedical Imaging & Therapy facility 05ID-2 beamline at the Canadian Light Source was pursued at 50 keV and at a pixel size of 4 µm to image dental bur fragments under a composite resin dental filling. The bur's cutting edges that produced the fragment were also chemically analyzed. The technique revealed dental bur fragments of different sizes in different locations on the floor of the prepared surface of the teeth and under the filling, which places them in direct contact with the dentinal tubules and the dentinal fluid circulating within them. Dispersive X-ray spectroscopy elemental analysis of the dental bur edges revealed that the fragments are made of tungsten carbide-cobalt, which is bio-incompatible.

  9. Electronic licensing filing system development and implementation experience

    International Nuclear Information System (INIS)

    Walderhaug, J.

    1993-01-01

    The Electronic Licensing Filing System (ELFS) is a microcomputer-based integrated document search and retrieval system for the Nuclear Regulatory Affairs Division of Southern California Edison (SCE). ELFS allows the user access to the current licensing basis of a subject by providing an easily searchable electronic information data base consisting of regulatory correspondence, design-bases documentation, licensing documents [updated final safety and analysis report (UFSAR) and technical specifications], and regulatory guidance or directives [10CFR, generic letters, bulletins, notices, circulars, regulatory guides, policy statements, and selected US Nuclear Regulatory Commission (NRC) regulations]. It is used in the preparation of correspondence and submittals to the NRC, 50.59 safety evaluations, design-bases reconstitution, and commitment tracking and management

  10. The microstructure of capsule containing self-healing materials: A micro-computed tomography study

    Energy Technology Data Exchange (ETDEWEB)

    Van Stappen, Jeroen, E-mail: Jeroen.Vanstappen@ugent.be [UGCT/PProGRess, Dept. of Geology, Ghent University, Krijgslaan 281 S8, B-9000 Ghent (Belgium); SIM vzw, Technologiepark 935, B-9052 Zwijnaarde (Belgium); Bultreys, Tom [UGCT/PProGRess, Dept. of Geology, Ghent University, Krijgslaan 281 S8, B-9000 Ghent (Belgium); Gilabert, Francisco A. [Mechanics of Materials and Structures, Dept. of Materials Science and Engineering, Ghent University, Technologiepark Zwijnaarde 903, B-9052 Zwijnaarde (Belgium); SIM vzw, Technologiepark 935, B-9052 Zwijnaarde (Belgium); Hillewaere, Xander K.D. [Polymer Chemistry Research Group, Dept. of Organic and Macromolecular Chemistry, Ghent University, Krijgslaan 281 S4-bis, B-9000 Ghent (Belgium); SIM vzw, Technologiepark 935, B-9052 Zwijnaarde (Belgium); Gómez, David Garoz [Mechanics of Materials and Structures, Dept. of Materials Science and Engineering, Ghent University, Technologiepark Zwijnaarde 903, B-9052 Zwijnaarde (Belgium); SIM vzw, Technologiepark 935, B-9052 Zwijnaarde (Belgium); Van Tittelboom, Kim [Magnel Laboratory for Concrete Research, Dept. of Structural Engineering, Ghent University, Technologiepark Zwijnaarde 904, B-9052 Ghent (Belgium); Dhaene, Jelle [UGCT/Radiation Physics, Dept. of Physics and Astronomy, Ghent University, Proeftuinstraat 86, B-9000 Ghent (Belgium); De Belie, Nele [Magnel Laboratory for Concrete Research, Dept. of Structural Engineering, Ghent University, Technologiepark Zwijnaarde 904, B-9052 Ghent (Belgium); Van Paepegem, Wim [Mechanics of Materials and Structures, Dept. of Materials Science and Engineering, Ghent University, Technologiepark Zwijnaarde 903, B-9052 Zwijnaarde (Belgium); Du Prez, Filip E. [Polymer Chemistry Research Group, Dept. of Organic and Macromolecular Chemistry, Ghent University, Krijgslaan 281 S4-bis, B-9000 Ghent (Belgium); Cnudde, Veerle [UGCT/PProGRess, Dept. of Geology, Ghent University, Krijgslaan 281 S8, B-9000 Ghent (Belgium)

    2016-09-15

    Autonomic self-healing materials are materials with built-in (micro-) capsules or vessels, which upon fracturing release healing agents in order to recover the material's physical and mechanical properties. In order to better understand and engineer these materials, a thorough characterization of the material's microstructural behavior is essential and often overlooked. In this context, micro-computed tomography (μCT) can be used to investigate the three dimensional distribution and (de)bonding of (micro-) capsules in their native state in a polymer system with self-healing properties. Furthermore, in-situ μCT experiments in a self-healing polymer and a self-healing concrete system can elucidate the breakage and leakage behavior of (micro-) capsules at the micrometer scale. While challenges related to image resolution and contrast complicate the characterization in specific cases, non-destructive 3D imaging with μCT is shown to contribute to the understanding of the link between the microstructure and the self-healing behavior of these complex materials. - Highlights: • μCT imaging allows for the analysis of microcapsule distribution patterns in self-healing materials. • μCT allows for qualitative and quantitative measurements of healing agent release from carriers in self-healing materials. • Experimental set-ups can be optimized by changing chemical compounds in the system to ensure maximum quality imaging.

  11. Microcomputer-based instrument for the detection and analysis of precession motion in a gas centrifuge machine. Revision 1

    International Nuclear Information System (INIS)

    Paulus, S.S.

    1986-03-01

    The Centrifuge Procession Analyzer (CPA) is a microcomputer-based instrument which detects precession motion in a gas centrifuge machine and calculates the amplitude and frequency of precession. The CPA consists of a printed circuit board which contains signal-conditioning circuitry and a 24-bit counter and an INTEL iSBC 80/24 single/board computer. Pression motion is detected by monitoring a signal generated by a variable reluctance pick-up coil in the top of the centrifuge machine. This signal is called a Fidler signal. The initial Fidler signal triggers a counter which is clocked by a high-precision, 20.000000-MHz, temperature-controlled, crystal oscillator. The contents of the counter are read by the computer and the counter reset after every ten Fidler signals. The speed of the centrifuge machine and the amplitude and frequency of precession are calculated and the results are displayed on a liquid crystal display on the front panel of the CPA. The report contains results from data generated by a Fidler signal simulator and data taken when the centrifuge was operated under three test conditions: (1) nitrogen gas during drive-up, steady state, and drive-down; (2) xenon gas during slip test, steady state, and the addition of gas; and (3) no gas during steady state. The qualitative results were consistent with experience with centrifuge machines using UF 6 in that the amplitude of precession increased and the frequency of precession decreased during drive-up, drive-down and the slip check. The magnitude of the amplitude and frequency of precession were proportional to the molecular weight of the gases in steady state

  12. The Design and Development of Educational Materials Using Microcomputer Technology in Distance Teaching Institutions: Some Issues for Consideration.

    Science.gov (United States)

    Yates, Christopher

    Perhaps the most significant development in microcomputer technology over the last two years has been the development of desktop publishing techniques. This technology promises to offer some significant advantages to institutions developing instructional materials in less developed countries, particularly in terms of control, cost effectiveness,…

  13. Designation and Implementation of Microcomputer Principle and Interface Technology Virtual Experimental Platform Website

    Science.gov (United States)

    Gao, JinYue; Tang, Yin

    This paper explicitly discusses the designation and implementation thought and method of Microcomputer Principle and Interface Technology virtual experimental platform website construction. The instructional design of this platform mainly follows with the students-oriented constructivism learning theory, and the overall structure is subject to the features of teaching aims, teaching contents and interactive methods. Virtual experiment platform production and development should fully take the characteristics of network operation into consideration and adopt relevant technologies to improve the effect and speed of network software application in internet.

  14. Control system for several rotating mirror camera synchronization operation

    Science.gov (United States)

    Liu, Ningwen; Wu, Yunfeng; Tan, Xianxiang; Lai, Guoji

    1997-05-01

    This paper introduces a single chip microcomputer control system for synchronization operation of several rotating mirror high-speed cameras. The system consists of four parts: the microcomputer control unit (including the synchronization part and precise measurement part and the time delay part), the shutter control unit, the motor driving unit and the high voltage pulse generator unit. The control system has been used to control the synchronization working process of the GSI cameras (driven by a motor) and FJZ-250 rotating mirror cameras (driven by a gas driven turbine). We have obtained the films of the same objective from different directions in different speed or in same speed.

  15. Micro-computed tomography visualization of the vestigial alimentary canal in adult oestrid flies.

    Science.gov (United States)

    Martín-Vega, D; Garbout, A; Ahmed, F; Ferrer, L M; Lucientes, J; Colwell, D D; Hall, M J R

    2018-02-16

    Oestrid flies (Diptera: Oestridae) do not feed during the adult stage as they acquire all necessary nutrients during the parasitic larval stage. The adult mouthparts and digestive tract are therefore frequently vestigial; however, morphological data on the alimentary canal in adult oestrid flies are scarce and a proper visualization of this organ system within the adult body is lacking. The present work visualizes the morphology of the alimentary canal in adults of two oestrid species, Oestrus ovis L. and Hypoderma lineatum (de Villiers), with the use of non-invasive micro-computed tomography (micro-CT) and compares it with the highly developed alimentary canal of the blow fly Calliphora vicina Robineau-Desvoidy (Diptera: Calliphoridae). Both O. ovis and H. lineatum adults showed significant reductions of the cardia and the diameter of the digestive tract, an absence of the helicoidal portion of the midgut typical of other cyclorrhaphous flies, and a lack of crop and salivary glands. Given the current interest in the alimentary canal in adult dipterans in biomedical and developmental biology studies, further understanding of the morphology and development of this organ system in adult oestrids may provide valuable new insights in several areas of research. © 2018 The Royal Entomological Society.

  16. An evaluation and implementation study of the Zenith 120 microcomputer in West Coast Fleet Commands

    OpenAIRE

    Barnett, George A.

    1985-01-01

    Approved for public release; distribution is unlimited Austere funding and the increased administrative burdens being placed on fleet units will ultimately take their toll on performance, morale and combat readiness. Applying low cost microcomputer technology presents one method to alleviate many of these burdens. However, the current implementation process being used is not sufficient to meet the needs of the Fleet. Empirical evidence indicates that expenditures on computers are not ac...

  17. Intelligent Operation and Maintenance of Micro-grid Technology and System Development

    Science.gov (United States)

    Fu, Ming; Song, Jinyan; Zhao, Jingtao; Du, Jian

    2018-01-01

    In order to achieve the micro-grid operation and management, Studying the micro-grid operation and maintenance knowledge base. Based on the advanced Petri net theory, the fault diagnosis model of micro-grid is established, and the intelligent diagnosis and analysis method of micro-grid fault is put forward. Based on the technology, the functional system and architecture of the intelligent operation and maintenance system of micro-grid are studied, and the microcomputer fault diagnosis function is introduced in detail. Finally, the system is deployed based on the micro-grid of a park, and the micro-grid fault diagnosis and analysis is carried out based on the micro-grid operation. The system operation and maintenance function interface is displayed, which verifies the correctness and reliability of the system.

  18. Development report: Automatic System Test and Calibration (ASTAC) equipment

    Science.gov (United States)

    Thoren, R. J.

    1981-01-01

    A microcomputer based automatic test system was developed for the daily performance monitoring of wind energy system time domain (WEST) analyzer. The test system consists of a microprocessor based controller and hybrid interface unit which are used for inputing prescribed test signals into all WEST subsystems and for monitoring WEST responses to these signals. Performance is compared to theoretically correct performance levels calculated off line on a large general purpose digital computer. Results are displayed on a cathode ray tube or are available from a line printer. Excessive drift and/or lack of repeatability of the high speed analog sections within WEST is easily detected and the malfunctioning hardware identified using this system.

  19. Utilization of a Microcomputer for the Study of an Iodine Oxidation and Equilibrium Reaction: A Physical Chemistry Experiment.

    Science.gov (United States)

    Julien, L. M.

    1984-01-01

    Describes a physical chemistry experiment which incorporates the use of a microcomputer to enhance understanding of combined kinetic and equilibrium phenomena, to increase experimental capabilities when working with large numbers of students and limited equipment, and for the student to develop a better understanding of experimental design. (JN)

  20. A local area network and information management system for a submarine overhaul facility

    OpenAIRE

    Bushmire, Jeffrey D

    1990-01-01

    A preliminary design of a local area network for a submarine overhaul facility is developed using System Engineering concepts. SOFLAN, the Submarine Overhaul Facility Local Area Network, is necessary to provide more timely and accurate information to submarine overhaul managers in order to decrease the overhaul time period and become more competitive. The network is a microcomputer based system following the Ethernet and IEEE 802.3 standards with a server .. client architecture. SOFLAN serves...

  1. Two digital X-ray imaging systems for applications in X-ray diffraction

    International Nuclear Information System (INIS)

    Bateman, J.E.; Connolly, J.F.; Stephenson, R.; Flesher, A.C.; Tucker, P.A.; Swanton, S.W.

    1987-01-01

    Two digital X-ray imaging systems developed at the Rutherford Appleton Laboratory are described: the Mark I and the Mark II. Both use a bidimensionally sensitive multiwire proportional counter (MWPC) as the basic X-ray image transducer coupled, in the case of the Mark I to a Digital LSI 11-23 microcomputer system via CAMAC, and in the case of the Mark II to a Digital LSI 11-73 microcomputer system via custom-built data acquisition hardware mounted directly on the Q-bus of the microcomputer. The Mark I system provides the advantages of high speed, high sensitivity digital imaging directly into the computer with the potential for software control of the sample orientation and environment. The Mark II system adds the novel features of signal averaging and multiframe exposures. The dedicated digital memories have a resolution of 512x512 pixels of 16 bits, matching well to the spatial resolution of the xenon-filled MWPC (0.5 mm fwhm over an aperture of 200 mm x 200 mm). A 512x512x4 bit video graphics system displays the images in grey scales or colour. (orig.)

  2. Moscow University race-track microtron control system: ideas and development

    International Nuclear Information System (INIS)

    Chepurnov, A.S.; Gribov, I.V.; Morozov, S.Yu.; Shumakov, A.V.; Zinoviev, S.V.

    1992-01-01

    Moscow University race-track microtron (RTM) control system is a star-shape network of LSI-11 compatible microcomputers. Each of them is connected with RTM systems via CAMAC; optical fiber coupling is also used. Control system software is designed on Pascal-1, supplemented with real time modules and Macro. A unified real time technique and reenterable data acquisition drivers allow to simplify development of control drivers and algorithms. Among the latter three main types are used: DDC methods, those, based on optimization technique and algorithms, applying models of microtron's systems. Man-machine interface is based on concept of the 'world of accelerator'. It supports means to design, within hardware possibilities, various computer images of the RTM. (author)

  3. Descriptions of Transit Maintenance Management Information Systems

    Science.gov (United States)

    1984-10-01

    This 289-page report presents an overview of ten maintenance management information systems that are currently operational or near-operational on minicomputers or microcomputers. The systems described address one or more of the following concerns: co...

  4. Creation of a Book Order Management System Using a Microcomputer and a DBMS.

    Science.gov (United States)

    Neill, Charlotte; And Others

    1985-01-01

    Describes management decisions and resultant technology-based system that allowed a medical library to meet increasing workloads without accompanying increases in resources available. Discussion covers system analysis; capabilities of book-order management system, "BOOKDIRT;" software and training; hardware; data files; data entry;…

  5. Control systems in optical fibre industry

    Czech Academy of Sciences Publication Activity Database

    Kostka, František

    1998-01-01

    Roč. 1, č. 4 (1998), s. 195-200 ISSN 1405-5546 Grant - others:AV ČR(CZ) KSK1067601 Projekt 10/96/K:4107 Keywords : control systems * real time systems * microcomputers * optical fibres Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering

  6. Design of real-time monitoring and control system of 222Rn/220Rn sampling for radon chamber

    International Nuclear Information System (INIS)

    Wu Rongyan; Zhao Xiuliang; Zhang Meiqin; Yu Hong

    2008-01-01

    This paper describes the design of 222 Rn/ 220 Rn sampling monitoring and control system based on single-chip microcomputer of series Intel51. The hardware design involves the choosing and usage of sensors-chips, A/D conversion-chip, USB interface-chip, keyboard-chip, digital display-chip, photoelectric coupling isolation-chips and drive circuit-chips of the direct current pump. Software design is composed by software of Personal Computer (PC) and software of Single Chip Microcomputer (SCM). The data acquisition and conversion and the flux control of direct current pump are realized by using soft of Visual Basic and assemble language. The program flow charts are given. Furthermore, we improved the stability of the direct current pump by means of PID Control Algorithms. (authors)

  7. GAMANAL-PC: a program for gamma-ray spectrum analysis using a microcomputer

    International Nuclear Information System (INIS)

    Heimlich, M.; Beeley, P.A.; Page, J.A.

    1989-01-01

    GAMANAL was modified to operate on a microcomputer. The program uses an algorithm involving a Gaussian and a tailing term for fitting and resolving peaks obtained from spectrometers using Ge semiconductor detectors. Gamma-ray energies, intensities and absolute photon emission rates can be determined. A graphical output showing the original and fitted data can also be obtained. The results generated by the program are stored on disk as ASCII files for further analysis. This allows the use of other computer programs and languages in tasks such as decay curve analysis, radionuclide activity measurements and neutron activation analysis. (author) 11 refs.; 2 figs.; 4 tabs

  8. Computer-based diagnostic decisionmaking.

    Science.gov (United States)

    Miller, R A

    1987-12-01

    The three decisionmaking aids described by the authors attack the generic problem of "see no evil, hear no evil, speak no evil"--improving the detection, diagnosis, and therapy of psychiatric disorders in the primary care setting. The three systems represent interventions at different steps in the process of providing appropriate care to psychiatric patients. The DSPW system of Robins and Marcus offers the potential of increasing the recognition of psychiatric disease in the physician's office. Politser's IDS program is representative of the sort of sophisticated microcomputer-based decisionmaking support tools that will become available to physicians in the not-too-distant future. Erdman's study of the impact of explanation capabilities on the acceptability of therapy recommending systems points out the need for careful scientific evaluations of features added to diagnostic and therapeutic systems.

  9. Monte Carlo calculations of electron transport on microcomputers

    International Nuclear Information System (INIS)

    Chung, Manho; Jester, W.A.; Levine, S.H.; Foderaro, A.H.

    1990-01-01

    In the work described in this paper, the Monte Carlo program ZEBRA, developed by Berber and Buxton, was converted to run on the Macintosh computer using Microsoft BASIC to reduce the cost of Monte Carlo calculations using microcomputers. Then the Eltran2 program was transferred to an IBM-compatible computer. Turbo BASIC and Microsoft Quick BASIC have been used on the IBM-compatible Tandy 4000SX computer. The paper shows the running speed of the Monte Carlo programs on the different computers, normalized to one for Eltran2 on the Macintosh-SE or Macintosh-Plus computer. Higher values refer to faster running times proportionally. Since Eltran2 is a one-dimensional program, it calculates energy deposited in a semi-infinite multilayer slab. Eltran2 has been modified to a two-dimensional program called Eltran3 to computer more accurately the case with a point source, a small detector, and a short source-to-detector distance. The running time of Eltran3 is about twice as long as that of Eltran2 for a similar case

  10. The new control system of the Saclay linear accelerator

    International Nuclear Information System (INIS)

    Gournay, J.F.

    1985-10-01

    A new control system for the Saclay Linear Accelerator designed during the two past years is now in operation. The computer control architecture is based on 3 dedicated VME crates: one crate with a disk-based operating system runs the high level application programs and the database management facilities, another one manages the man-machine communications and the third one interfaces the system to the linac equipments. At the present time, communications between the VME micro-computers are done through 16 bit parallel links. The software is modular and organized in specific layers, the database is fully distributed. About 90% of the code is written in Fortran. The present status of the system is discussed and the hardware and software developments are described

  11. MICROSHIELD - a microcomputer program for analyzing dose rate and gamma shielding

    International Nuclear Information System (INIS)

    Negin, C.A.

    1986-01-01

    Until recently, dose rate (exposure rate) and shielding effectiveness calculations have been conducted by specialists, either within an organization or by consultants. Now, the capability to perform these calculations is available to engineers and health physicists with desktop computers. MICROSHIELD is one program that provides this capability. The overall objective in creating MICROSHIELD was to provide a program that would relieve a user from the need to be a shielding analysis expert or to be familiar with how microcomputers operate. The goal was to allow a person to focus on the decision for which an analysis is required instead of on the analysis itself. The purpose of this paper is to describe some of the means by which this objective was achieved

  12. NORTHWOODS Wildlife Habitat Data Base

    Science.gov (United States)

    Mark D. Nelson; Janine M. Benyus; Richard R. Buech

    1992-01-01

    Wildlife habitat data from seven Great Lakes National Forests were combined into a wildlife-habitat matrix named NORTHWOODS. Several electronic file formats of NORTHWOODS data base and documentation are available on floppy disks for microcomputers.

  13. An intelligent fetal monitoring system

    International Nuclear Information System (INIS)

    Inaba, J.; Akatsuka, T.; Kubo, T.; Iwasaki, H.

    1986-01-01

    An intelligent monitoring system is constructed by a multi-micro-computer system. The monitoring signals are fetal heart rate (FHR) and uterine contraction (UC) through the conventional monitoring device for a day until the delivery. These signals are fed to a micro-computer in digital format, and evaluated by the computer in real time according to the diagnostic algorithm of the expert physician. Monitoring signals are always displayed on the CRT screen and in the case of dangerous state of the fetus, warning signal will appear on the screen and the doctor or nurse will be called. All these signals are sent to the next micro-computer with 10MB hard disk system. On this computer, the doctor and nurse can retrieve and inspect the details of the process by clock-key and/or events-key. After finishing monitoring process, summarized report is constructed and printed out on the paper

  14. Update on radiation-hardened microcomputers for robotics and teleoperated systems

    International Nuclear Information System (INIS)

    Sias, F.R. Jr.; Tulenko, J.S.

    1993-01-01

    Since many programs sponsored by the Department of Defense are being canceled, it is important to select carefully radiation-hardened microprocessors for projects that will mature (or will require continued support) several years in the future. At the present time there are seven candidate 32-bit processors that should be considered for long-range planning for high-performance radiation-hardened computer systems. For Department of Energy applications it is also important to consider efforts at standardization that require the use of the VxWorks operating system and hardware based on the VMEbus. Of the seven processors, one has been delivered and is operating and other systems are scheduled to be delivered late in 1993 or early in 1994. At the present time the Honeywell-developed RH32, the Harris RH-3000 and the Harris RHC-3000 are leading contenders for meeting DOE requirements for a radiation-hardened advanced 32-bit microprocessor. These are all either compatible with or are derivatives of the MIPS R3000 Reduced Instruction Set Computer. It is anticipated that as few as two of the seven radiation-hardened processors will be supported by the space program in the long run

  15. On the description of fault-tolerant systems

    International Nuclear Information System (INIS)

    Syrbe, M.

    1980-01-01

    Various demands by increasing complexity and the disposability of new technologies, like the One-chip-microcomputer and fiber optics, lead to control systems, which are built as decentralized distributed multi-microcomputersystems. They realize not only new control functions but they also open possibilities to increase availability by fault-tolerance. The design or the selection and lay-out of such systems require a quantitative description of these systems. This is possible on the bases of the set of hardware and software moduls of the system by the use of queuing models, reliability nets and diagnostic graphs. This is shown by an example of a practically applied Really Distributed Computer Control System (RDC-System). Computer aided methods for these system descriptions are emphasized. (orig.) [de

  16. Micro-computed tomography-based phenotypic approaches in embryology: procedural artifacts on assessments of embryonic craniofacial growth and development.

    Science.gov (United States)

    Schmidt, Eric J; Parsons, Trish E; Jamniczky, Heather A; Gitelman, Julian; Trpkov, Cvett; Boughner, Julia C; Logan, C Cairine; Sensen, Christoph W; Hallgrímsson, Benedikt

    2010-02-17

    Growing demand for three dimensional (3D) digital images of embryos for purposes of phenotypic assessment drives implementation of new histological and imaging techniques. Among these micro-computed tomography (microCT) has recently been utilized as an effective and practical method for generating images at resolutions permitting 3D quantitative analysis of gross morphological attributes of developing tissues and organs in embryonic mice. However, histological processing in preparation for microCT scanning induces changes in organ size and shape. Establishing normative expectations for experimentally induced changes in size and shape will be an important feature of 3D microCT-based phenotypic assessments, especially if quantifying differences in the values of those parameters between comparison sets of developing embryos is a primary aim. Toward that end, we assessed the nature and degree of morphological artifacts attending microCT scanning following use of common fixatives, using a two dimensional (2D) landmark geometric morphometric approach to track the accumulation of distortions affecting the embryonic head from the native, uterine state through to fixation and subsequent scanning. Bouin's fixation reduced average centroid sizes of embryonic mouse crania by approximately 30% and substantially altered the morphometric shape, as measured by the shift in Procrustes distance, from the unfixed state, after the data were normalized for naturally occurring shape variation. Subsequent microCT scanning produced negligible changes in size but did appear to reduce or even reverse fixation-induced random shape changes. Mixtures of paraformaldehyde + glutaraldehyde reduced average centroid sizes by 2-3%. Changes in craniofacial shape progressively increased post-fixation. The degree to which artifacts are introduced in the generation of random craniofacial shape variation relates to the degree of specimen dehydration during the initial fixation. Fixation methods that

  17. System for measuring desired parameters in a monitored environment

    International Nuclear Information System (INIS)

    Wassel, W.; Remley, G.W.

    1980-01-01

    For flux recording of the reactor, e.g. PWR, two groups of neutron detectors are applied. They are controlled by a driving microcomputer. Both groups of detectors continue to be assigned to proccessors consisting each of a peripheral microcomputer and transferring the information containing instructions from the control panel to the two driving microcomputers via cache memories that have got two accesses. The data from the detectors are transferred an the other hand via the cache memories and the driving microcomputers to the peripheral microcomputers. (DG) [de

  18. Temperature control system for liquid-fed ceramic melters

    International Nuclear Information System (INIS)

    Westsik, J.H. Jr.

    1986-10-01

    A temperature-feedback system has been developed for controlling electrical power to liquid-fed ceramic melters (LFCM). Software, written for a microcomputer-based data acquisition and process monitoring system, compares glass temperatures with a temperature setpoint and adjusts the electrical power accordingly. Included in the control algorithm are steps to reject failed thermocouples, spatially average the glass temperatures, smooth the averaged temperatures over time using a digital filter, and detect foaming in the glass. The temperature control system has proved effective during all phases of melter operation including startup, steady operation, loss of feed, and shutdown. This system replaces current, power, and resistance feedback control systems used previously in controlling the LFCM process

  19. Root canal morphology of primary molars: a micro-computed tomography study.

    Science.gov (United States)

    Fumes, A C; Sousa-Neto, M D; Leoni, G B; Versiani, M A; da Silva, L A B; da Silva, R A B; Consolaro, A

    2014-10-01

    This was to investigate the root canal morphology of primary molar teeth using micro-computed tomography. Primary maxillary (n = 20) and mandibular (n = 20) molars were scanned at a resolution of 16.7 μm and analysed regarding the number, location, volume, area, structured model index (SMI), area, roundness, diameters, and length of canals, as well as the thickness of dentine in the apical third. Data were statistically compared by using paired-sample t test, independent sample t test, and one-way analysis of variance with significance level set as 5%. Overall, no statistical differences were found between the canals with respect to length, SMI, dentine thickness, area, roundness, and diameter (p > 0.05). A double canal system was observed in the mesial and mesio-buccal roots of the mandibular and maxillary molars, respectively. The thickness in the internal aspect of the roots was lower than in the external aspect. Cross-sectional evaluation of the roots in the apical third showed flat-shaped canals in the mandibular molars and ribbon- and oval-shaped canals in the maxillary molars. External and internal anatomy of the primary first molars closely resemble the primary second molars. The reported data may help clinicians to obtain a thorough understanding of the morphological variations of root canals in primary molars to overcome problems related to shaping and cleaning procedures, allowing appropriate management strategies for root canal treatment.

  20. Experiences with on line fault detection system for protection system logic and decay heat removal system logic in Dhruva

    International Nuclear Information System (INIS)

    Ramkumar, N.; Dutta, P.K.; Darbhe, M.D.; Bharadwaj, G.

    2001-01-01

    Dhruva is a 100 MW (Thermal) natural uranium fuelled, vertical core, tank type multi purpose research reactor with heavy water acting as moderator, coolant and reflector. Helium is used as cover gas for heavy water system. Reactor Protection System and Decay Heat Removal System (DHRS) have triplicated instrumented channels. The logic for these systems are hybrid in nature with a mixture of relay logic and solid state logic. Fine Impulse Technique(FIT) is employed for On-line fault detection in the solid state logics of these systems. The FIT systems were designed in the early eighties. Operating experiences over the past 15 years has revealed certain deficiencies. In view of this, a microcomputer based state of the art FIT systems for logics of Reactor Protection System and DHRS are being implemented with improved functionalities built into them. This paper describes the operating experience of old FIT systems and improved features of the proposed new FIT systems. (author)