Sample records for microbubble contrast agents

  1. Ultrasound Contrast Agent Microbubble Dynamics

    NARCIS (Netherlands)

    Overvelde, M.L.J.; Vos, Henk; de Jong, N.; Versluis, Michel; Paradossi, Gaio; Pellegretti, Paolo; Trucco, Andrea

    2010-01-01

    Ultrasound contrast agents are traditionally used in ultrasound-assisted organ perfusion imaging. Recently the use of coated microbubbles has been proposed for molecular imaging applications where the bubbles are covered with a layer of targeting ligands to bind specifically to their target cells.

  2. Nonspherical oscilllations of ultrasound contrast agent microbubbles

    NARCIS (Netherlands)

    Dollet, B.; van der Meer, S.M.; Garbin, V.; Garbin, Valeria; de Jong, N.; Lohse, Detlef; Versluis, Michel

    2008-01-01

    The occurrence of nonspherical oscillations (or surface modes) of coated microbubbles, used as ultrasound contrast agents in medical imaging, is investigated using ultra–high-speed optical imaging. Optical tweezers designed to micromanipulate single bubbles in 3-D are used to trap the bubbles far

  3. Collapse dynamics of ultrasound contrast agent microbubbles

    Science.gov (United States)

    King, Daniel Alan

    Ultrasound contrast agents (UCAs) are micron-sized gas bubbles encapsulated with thin shells on the order of nanometers thick. The damping effects of these viscoelastic coatings are widely known to significantly alter the bubble dynamics for linear and low-amplitude behavior; however, their effects on strongly nonlinear and destruction responses are much less studied. This dissertation examines the behaviors of single collapsing shelled microbubbles using experimental and theoretical methods. The study of their dynamics is particularly relevant for emerging experimental uses of UCAs which seek to leverage localized mechanical forces to create or avoid specialized biomedical effects. The central component in this work is the study of postexcitation rebound and collapse, observed acoustically to identify shell rupture and transient inertial cavitation of single UCA microbubbles. This time-domain analysis of the acoustic response provides a unique method for characterization of UCA destruction dynamics. The research contains a systematic documentation of single bubble postexcitation collapse through experimental measurement with the double passive cavitation detection (PCD) system at frequencies ranging from 0.9 to 7.1 MHz and peak rarefactional pressure amplitudes (PRPA) ranging from 230 kPa to 6.37 MPa. The double PCD setup is shown to improve the quality of collected data over previous setups by allowing symmetric responses from a localized confocal region to be identified. Postexcitation signal percentages are shown to generally follow trends consistent with other similar cavitation metrics such as inertial cavitation, with greater destruction observed at both increased PRPA and lower frequency over the tested ranges. Two different types of commercially available UCAs are characterized and found to have very different collapse thresholds; lipid-shelled Definity exhibits greater postexcitation at lower PRPAs than albumin-shelled Optison. Furthermore, by altering

  4. Superparamagnetic nanoparticle-inclusion microbubbles for ultrasound contrast agents

    International Nuclear Information System (INIS)

    Yang Fang; Li Yixin; Chen Zhongping; Gu Ning; Li Ling; Wu Junru

    2008-01-01

    We have developed a new type of ultrasound (US) contrast agent, consisting of a gas core, a layer of superparamagnetic iron oxide Fe 3 O 4 nanoparticles (SPIO) and an oil in water outermost layer. The newly developed US contrast agent microbubbles have a mean diameter of 760 nm with a polydisperity index (PI) of 0.699. Our in vitro and in vivo experiments have shown that they have the following advantages compared to gas-encapsulated microbbubbles without SPIO inclusion: (1) they provide better contrast for US images; (2) the SPIO-inclusion microbubbles generate a higher backscattering signal; the mean grey scale is 97.9, which is 38.6 higher than that of microbubbles without SPIO; and (3) since SPIO can also serve as a contrast agent of magnetic resonance images (MRI) in vitro, they can be potentially used as contrast agents for double-modality (MRI and US) clinical studies.

  5. Biological in situ characterization of polymeric microbubble contrast agents

    NARCIS (Netherlands)

    Wan, Sha; Egri, Gabriella; Oddo, Letizia; Cerroni, Barbara; Dähne, Lars; Paradossi, Gaio; Salvati, Anna; Lynch, Iseult; Dawson, Kenneth A; Monopoli, Marco P

    Polymeric microbubbles (MBs) are gas filled particles composed of a thin stabilized polymer shell that have been recently developed as valid contrast agents for the combined use of ultrasonography (US), magnetic resonance imaging (MRI) and single photon emission computer tomography (SPECT) imaging.

  6. Development of microbubble contrast agents for high frequency ultrasound microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Jun, Se Jung; Kim, Eun A; Park, Sung Hoon; Lee, Hye Jin; Jun, Hong Young; Byun, Seung Jae; Yoon, Kwon Ha [Wonkwang University School of Medicine, Iksan (Korea, Republic of)

    2007-05-15

    To develop optimal microbubble contrast agents (MBCAs) for performing ultrasound microscopy when examining small animals. We prepared three types of MBCAs. First, a mixture of three parts of 40% dextran and one part of 5% human serum albumin were sonicated with perfluorocarbon (PFC) (MB{sub 1}-D40A5P). Second, three parts of 40% dextran and one part of 1% human serum albumin were sonicated with PFC (MB{sub 2}-D40A1P). Third, all parts of 1% bovine serum albumin were sonicated with PFC (MB{sub 3}-A1P). We measured the microbubbles' sizes and concentrations with using image analysis software. The acoustic properties of the microbubbles were assessed both in vitro and in vivo. The majority of the MB{sub 1}-D40A5Ps had a diameter of 2-5 {mu} m, the mean diameter of the MB{sub 2}-D40A1Ps was 2.5 {mu} m, and the mean diameter of the MB{sub 3}-A1Ps was less than 2.0 {mu} m. Among the microbubbles, the MB{sub 1}-D40A5Ps and MB{sub 2}-D40A1Ps showed increased echogenicity in the abdominal vessels, but the duration of their contrast effect was less than 30 sec. On the contrary, the MB3-A1Ps exhibited strong enhancement in the vessels and their duration was greater than 120 sec. A microbubble contrast agent consisting of all parts of 1% serum albumin sonicated with PFC is an effective contrast agent for ultrasound microscopy.

  7. Microbubbles as contrast agent for in-line x-ray phase-contrast imaging

    International Nuclear Information System (INIS)

    Xi Yan; Zhao Jun; Tang Rongbiao; Wang Yujie

    2011-01-01

    In the present study, we investigated the potential of gas-filled microbubbles as contrast agents for in-line x-ray phase-contrast imaging (PCI) in biomedical applications. When imaging parameters are optimized, the microbubbles function as microlenses that focus the incoming x-rays to form bright spots, which can significantly enhance the image contrast. Since microbubbles have been shown to be safe contrast agents in clinical ultrasonography, this contrast-enhancement procedure for PCI may have promising utility in biomedical applications, especially when the dose of radiation is a serious concern. In this study, we performed both numerical simulations and ex vivo experiments to investigate the formation of the contrast and the effectiveness of microbubbles as contrast agents in PCI.

  8. Pinched flow fractionation of microbubbles for ultrasound contrast agent enrichment

    Science.gov (United States)

    Versluis, Michel; Kok, Maarten; Segers, Tim

    2014-11-01

    An ultrasound contrast agent (UCA) suspension contains a wide size distribution of encapsulated microbubbles (typically 1-10 μm in diameter) that resonate to the driving ultrasound field by the intrinsic relationship between bubble size and ultrasound frequency. Medical transducers, however, operate in a narrow frequency range, which severely limits the number of bubbles that contribute to the echo signal. Thus, the sensitivity can be improved by narrowing down the size distribution of the bubble suspension. Here, we present a novel, low-cost, lab-on-a-chip method for the sorting of contrast microbubbles by size, based on a microfluidic separation technique known as pinched flow fractionation (PFF). We show by experimental and numerical investigation that the inclusion of particle rotation is essential for an accurate physical description of the sorting behavior of the larger bubbles. Successful sorting of a bubble suspension with a narrow size distribution (3.0 +/- 0.6 μm) has been achieved with a PFF microdevice. This sorting technique can be easily parallelized, and may lead to a significant improvement in the sensitivity of contrast-enhanced medical ultrasound. This work is supported by NanoNextNL, a micro and nanotechnology consortium of the Government of the Netherlands and 130 partners.

  9. A novel technology: microfluidic devices for microbubble ultrasound contrast agent generation.

    Science.gov (United States)

    Lin, Hangyu; Chen, Junfang; Chen, Chuanpin

    2016-09-01

    Microbubbles are used as ultrasound contrast agents, which enhance ultrasound imaging techniques. In addition, microbubbles currently show promise in disease therapeutics. Microfluidic devices have increased the ability to produce microbubbles with precise size, and high monodispersity compared to microbubbles created using traditional methods. This paper will review several variations in microfluidic device structures used to produce microbubbles as ultrasound contrast agents. Microfluidic device structures include T-junction, and axisymmetric and asymmetric flow-focusing. These devices have made it possible to produce microbubbles that can enter the vascular space; these microbubbles must be less than 10 μm in diameter and have high monodispersity. For different demands of microbubbles production rate, asymmetric flow-focusing devices were divided into individual and integrated devices. In addition, asymmetric flow-focusing devices can produce double layer and multilayer microbubbles loaded with drug or biological components. Details on the mechanisms of both bubble formation and device structures are provided. Finally, microfluidically produced microbubble acoustic responses, microbubble stability, and microbubble use in ultrasound imaging are discussed.

  10. Aptamer-crosslinked microbubbles: smart contrast agents for thrombin-activated ultrasound imaging.

    Science.gov (United States)

    Nakatsuka, Matthew A; Mattrey, Robert F; Esener, Sadik C; Cha, Jennifer N; Goodwin, Andrew P

    2012-11-27

    Thrombosis, or malignant blood clotting, is associated with numerous cardiovascular diseases and cancers. A microbubble contrast agent is presented that produces ultrasound harmonic signal only when exposed to elevated thrombin levels. Initially silent microbubbles are activated in the presence of both thrombin-spiked and freshly clotting blood in three minutes with detection limits of 20 nM thrombin and 2 aM microbubbles. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Ultrasound in Biomedical Engineering: Ultrasound Microbubble Contrast Agents Promote Transdermal Permeation of Drugs

    OpenAIRE

    Ai-Ho Liao

    2016-01-01

    This report discusses a new development in the use of ultrasound microbubble contrast agents on transdermal drug delivery. The medium surrounding the microbubbles at the optimum concentration from liquid to gel can be modified and it can still achieve the same enhancement for transdermal drug permeation as liquid medium. It was also found that under the same ultrasound power density, microbubbles of larger particle sizes can extend the penetration depths of dye at the phantom surface.

  12. Ultrasonic microbubble contrast agents and the transplant kidney

    Energy Technology Data Exchange (ETDEWEB)

    Kay, D.H., E-mail: davidhkay@doctors.org.u [Department of Radiology, Western Infirmary, Glasgow (United Kingdom); Mazonakis, M.; Geddes, C. [Department of Renal Medicine, Western Infirmary, Glasgow (United Kingdom); Baxter, G. [Department of Radiology, Western Infirmary, Glasgow (United Kingdom)

    2009-11-15

    Aim: To evaluate the potential application of microbubble agents in the immediate post-transplant period, by studying contrast uptake and washout, and to correlate these values with clinical indices, and thus, assess the potential prognostic value of this technique. Materials and methods: The study group comprised 20 consecutive renal transplant patients within 7 days of transplantation. Sonovue was administered as an intravenous bolus with continuous imaging of the transplant kidney at low mechanical index (MI) for 1 min post-injection. These data were analysed off-line by two observers, and time intensity curves (TIC) for the upper, mid, and lower poles constructed. Within each pole, a region of interest (5 mm square) was placed over the cortex, medullary pyramid, and interlobar artery, resulting in a total of nine TIC for each patient. TIC parameters included the arrival time (AT), time to peak (TTP), peak intensity (Max), gradient of the slope (M), and the area under curve (AUC). Results: For both observers there was good agreement for all values measured from the cortex and medulla, but poor interobserver correlation for the vascular values. In addition, there was only agreement for these values in the upper and mid-pole of the transplant with poor agreement for the lower pole values. The mid-pole of the transplant kidney was chosen as the point of measurement for subsequent studies. Mid-pole values were correlated with clinical data and outcome over the 3-month post-transplant period. Renal microbubble perfusion correlated with the transplant estimated glomerular filtration rate (eGFR) at 3 months post-transplantation (p = 0.016). Discussion: In conclusion, this is the first study to confirm reproducibility of the Sonovue TIC data in transplant patients and to quantify regional variation and perfusion. The statistically significant estimates of transplant perfusion may be of future benefit to transplant recipients and potentially utilized as a prognostic tool

  13. Hysteretic Nonlinearity of Sub-harmonic Emission from Ultrasound Contrast Agent Microbubbles

    International Nuclear Information System (INIS)

    Qiu Yuan-Yuan; Zhang Dong; Zheng Hai-Rong

    2011-01-01

    Sub-harmonic contrast imaging promises to improve ultrasound imaging quality by taking advantage of increased contrast to tissue signal. The aim of this study is to examine the hysteretic nonlinearity of sub-harmonic component emitted from microbubbles. Two kinds of microbubble solutions, i.e. Sonovue® and a self-developed contrast agent, are utilized in the study. The hysteretic curves for increasing and decreasing acoustic pressure are theoretically predicted by the Marmottant model and confirmed by measurements. The results reveal that for both microbubble solutions, the development of the rising ramp undergoes three stages, i.e. occurrence, growth and saturation; while hysteresis effect appears in the descending ramp. Sonovue® microbubbles exhibit better sub-harmonic performance over the self-developed UCAs microbubbles due to the difference of elastic properties of the shell. (fundamental areas of phenomenology(including applications))

  14. Effect of microbubble contrast agent during high intensity focused ultrasound ablation on rabbit liver in vivo

    International Nuclear Information System (INIS)

    Chung, Dong Jin; Cho, Se Hyun; Lee, Jae Mun; Hahn, Seong-Tae

    2012-01-01

    Objective: To evaluate the effect of a microbubble contrast agent (SonoVue) during HIFU ablation of a rabbit liver. Materials and methods: HIFU ablations (intensity of 400 W/cm 2 for 4 s, six times, with a 5 s interval between exposures) were performed upon 16 in vivo rabbit livers before and after intravenous injection of a microbubble contrast agent (0.8 ml). A Wilcoxon signed rank test was used to compare mean ablation volume and time required to tissue ablation on real-time US. Shape of ablation and pattern of coagulative necrosis were analyzed by Fisher's exact test. Results: The volume of coagulative necrosis was significantly larger in the combination microbubble and HIFU group than in the HIFU alone group (P < 0.05). Also, time to reach ablation was shorter in the combination microbubble and HIFU group than in the HIFU alone group (P < 0.05). When analyzing the shape of tissue ablation, a pyramidal shape was more prevalently in the HIFU alone group compared to the combination microbubble and HIFU group (P < 0.05). Following an analysis of the pattern of coagulative necrosis, non-cavitary necrosis was found in ten and cavitary necrosis in six of the samples in the combination microbubble and HIFU group. Conversely, non-cavitary necrosis occurred in all 16 samples in the HIFU alone group (P < 0.05). Conclusion: HIFU of in vivo rabbit livers with a microbubble contrast agent produced larger zones of ablation and more cavitary tissue necrosis than without the use of a microbubble contrast agent. Microbubble contrast agents may be useful in tissue ablation by enhancing the treatment effect of HIFU.

  15. Ultrasound-induced Gas Release from Contrast Agent Microbubbles

    NARCIS (Netherlands)

    Postema, M.A.B.; Postema, Michiel; Bouakaz, Ayache; Versluis, Michel; de Jong, N.

    2005-01-01

    We investigated gas release from two hard-shelled ultrasound contrast agents by subjecting them to high-mechanical index (MI) ultrasound and simultaneously capturing high-speed photographs. At an insonifying frequency of 1.7 MHz, a larger percentage of contrast bubbles is seen to crack than at 0.5

  16. Ultrasonically induced dynamics of a contrast agent microbubble between two parallel elastic walls

    International Nuclear Information System (INIS)

    Doinikov, Alexander A; Bouakaz, Ayache

    2013-01-01

    This work presents the derivation of a Rayleigh–Plesset-like equation that describes the radial oscillation of a contrast agent microbubble between two elastic walls, assuming that the bubble is attached to one of them. The obtained equation is then used in numerical simulations in order to establish how the presence of the second wall affects the resonance properties and the scattered echo of the contrast microbubble. The effect of encapsulation on the dynamics of the microbubble is simulated by the Marmottant shell model which is commonly used for the modeling of the dynamics of lipid-shelled contrast agents. Two cases are examined. In the first, the mechanical properties of the walls are set to correspond to OptiCell chambers which are widely used in experiments on microbubble contrast agents. In the second, the properties of the walls correspond to walls of blood vessels. It is shown that the presence of the second wall increases the resonance frequency of the contrast microbubble and decreases the amplitudes of the radial oscillation and the scattered echo of the microbubble as compared to the case that the second wall is absent. It is also shown that the presence of the second wall can change noticeably the intensity of the second harmonic in the spectrum of the scattered pressure. It is demonstrated that, depending on the value of the driving frequency, the presence of the second wall can either increase or decrease the intensity of the second harmonic as compared to its intensity in the case that the second wall is absent. (paper)

  17. Microbubble embedded with upconversion nanoparticles as a bimodal contrast agent for fluorescence and ultrasound imaging

    International Nuclear Information System (INIS)

    Jin, Birui; Lin, Min; You, Minli; Xu, Feng; Lu, Tianjian; Zong, Yujin; Wan, Mingxi; Duan, Zhenfeng

    2015-01-01

    Bimodal imaging offers additional imaging signal thus finds wide spread application in clinical diagnostic imaging. Fluorescence/ultrasound bimodal imaging contrast agent using fluorescent dyes or quantum dots for fluorescence signal has emerged as a promising method, which however requires visible light or UV irradiation resulting in photobleaching, photoblinking, auto-fluorescence and limited tissue penetration depth. To surmount these problems, we developed a novel bimodal contrast agent using layer-by-layer assembly of upconversion nanoparticles onto the surface of microbubbles. The resulting microbubbles with average size of 2 μm provide enhanced ultrasound echo for ultrasound imaging and upconversion emission upon near infrared irradiation for fluorescence imaging. The developed bimodal contrast agent holds great potential to be applied in ultrasound target technique for targeted diseases diagnostics and therapy. (paper)

  18. Quantitation of MRI sensitivity to quasi-monodisperse microbubble contrast agents for spatially resolved manometry.

    Science.gov (United States)

    Bencsik, Martin; Al-Rwaili, Amgad; Morris, Robert; Fairhurst, David J; Mundell, Victoria; Cave, Gareth; McKendry, Jonathan; Evans, Stephen

    2013-11-01

    The direct in-vivo measurement of fluid pressure cannot be achieved with MRI unless it is done with the contribution of a contrast agent. No such contrast agents are currently available commercially, whilst those demonstrated previously only produced qualitative results due to their broad size distribution. Our aim is to quantitate then model the MR sensitivity to the presence of quasi-monodisperse microbubble populations. Lipid stabilised microbubble populations with mean radius 1.2 ± 0.8 μm have been produced by mechanical agitation. Contrast agents with increasing volume fraction of bubbles up to 4% were formed and the contribution the bubbles bring to the relaxation rate was quantitated. A periodic pressure change was also continuously applied to the same contrast agent, until MR signal changes were only due to bubble radius change and not due to a change in bubble density. The MR data compared favourably with the prediction of an improved numerical simulation. An excellent MR sensitivity of 23 % bar(-1) has been demonstrated. This work opens up the possibility of generating microbubble preparations tailored to specific applications with optimised MR sensitivity, in particular MRI based in-vivo manometry. Copyright © 2012 Wiley Periodicals, Inc.

  19. Ultrasonographic detection of focal liver lesions: increased sensitivity and specificity with microbubble contrast agents

    International Nuclear Information System (INIS)

    Hohmann, J.; Albrecht, T.; Hoffmann, C.W.; Wolf, K.-J.

    2003-01-01

    Ultrasonography (US) is the first choice for screening patients with suspected liver lesions. However, due to a lack of contrast agents, US used to be less sensitive and specific compared with computed tomography (CT) and magnet resonance imaging (MRI). The advent of microbubble contrast agents increased both sensitivity and specificity dramatically. Rapid developments of the contrast agents as well as of special imaging techniques were made in recent years. Today numerous different US imaging methods exist which based either on Doppler or on harmonic imaging. They are using the particular behaviour of microbubbles in a sound field which varies depending on the energy of insonation (low/high mechanical index, MI) as well as on the properties of the agent themselves. Apart from just blood pool enhancement some agents have a hepatosplenic specific late phase. US imaging during this late phase using relatively high MI in phase inversion mode (harmonic imaging) or stimulated acoustic emission (SAE; Doppler method) markedly improves the detection of focal liver lesions and is also very helpful for lesion characterisation. With regards to detection, contrast enhanced US performs similarly to CT as shown by recent studies. Early results of studies using low MI imaging and the newer perfluor agents are also showing promising results for lesion detection. Low MI imaging with these agents has the advantage of real time imaging and is particularly helpful for characterisation of focal lesions based on their dynamic contrast behaviour. Apart from the techniques which based on the morphology of liver lesions there were some attempts for the detection of occult metastases or micrometastases by means of liver blood flow changes. Also in this field the use of US contrast agents appears to have advantages over formerly used non contrast-enhanced methods although no conclusive results are available yet

  20. Methylene blue microbubbles as a model dual-modality contrast agent for ultrasound and activatable photoacoustic imaging

    Science.gov (United States)

    Jeon, Mansik; Song, Wentao; Huynh, Elizabeth; Kim, Jungho; Kim, Jeesu; Helfield, Brandon L.; Leung, Ben Y. C.; Goertz, David E.; Zheng, Gang; Oh, Jungtaek; Lovell, Jonathan F.; Kim, Chulhong

    2014-01-01

    Ultrasound and photoacoustic imaging are highly complementary modalities since both use ultrasonic detection for operation. Increasingly, photoacoustic and ultrasound have been integrated in terms of hardware instrumentation. To generate a broadly accessible dual-modality contrast agent, we generated microbubbles (a standard ultrasound contrast agent) in a solution of methylene blue (a standard photoacoustic dye). This MB2 solution was formed effectively and was optimized as a dual-modality contrast solution. As microbubble concentration increased (with methylene blue concentration constant), photoacoustic signal was attenuated in the MB2 solution. When methylene blue concentration increased (with microbubble concentration held constant), no ultrasonic interference was observed. Using an MB2 solution that strongly attenuated all photoacoustic signal, high powered ultrasound could be used to burst the microbubbles and dramatically enhance photoacoustic contrast (>800-fold increase), providing a new method for spatiotemporal control of photoacoustic signal generation.

  1. Acoustic scattering from a contrast agent microbubble near an elastic wall of finite thickness

    International Nuclear Information System (INIS)

    Doinikov, Alexander A; Aired, Leila; Bouakaz, Ayache

    2011-01-01

    Interest in the problem under consideration in this study is motivated by targeted ultrasound imaging where one has to deal with microbubble contrast agents pulsating near blood vessel walls. A modified Rayleigh–Plesset equation is derived that describes the oscillation of a contrast agent microbubble near an elastic wall of finite thickness. It is assumed that the medium behind the wall is a fluid but it is shown that the equation obtained is easily transformable to the case that the medium behind the wall is an elastic solid. In contrast to the model of a rigid wall, which predicts decreasing natural frequency of a bubble near the wall, the elastic wall model reveals that the bubble natural frequency can both decrease and increase, and in cases of interest for medical applications, the bubble natural frequency usually increases. It is found that the influence of an elastic wall on the acoustic response of a bubble is determined by the ratio between a cumulative parameter, which integrally characterizes the mechanical properties of the wall and has the dimension of density, and the density of the liquid surrounding the bubble. It is shown that the acoustic influence of the arterial wall on the bubble is weak and apparently cannot be used to recognize the moment when the bubble approaches the wall. However, in experiments where the behavior of bubbles near various plastic walls is observed, changes in the bubble response, such as increasing natural frequency and decreasing oscillation amplitude, are detectable.

  2. Fabrication and imaging study of ultrasound/fluorescence bi-modal contrast agent based on polymeric microbubbles

    International Nuclear Information System (INIS)

    Xing Zhanwen; Ke Hengte; Wang Jinrui; Zhao Bo; Qu Enze; Yue Xiuli; Dai Zhifei

    2013-01-01

    Objective: To fabricate an ultrasound/fluorescence bi-modal contrast agent by encapsulating fluorescent quantum dots into polymeric ultrasound contrast agent microbubbles. Methods: Polylactic acid (PLA, 500 mg), (1R)-(+)-camphor (50 mg) and CdSe/ZnS quantum dots (0.5 ml, 2.3 μmol/L)were dissolved or dispersed in dichloromethane (10 ml) to form in an organic phase. Ammonium carbonate solution and poly (vinyl alcohol) solution were employed as the internal and external water phase, respectively. The fluorescent microbubbles were generated using double emulsion solvent evaporation and lyophilization methods. The morphology and illumination were characterized by scanning electron microscopy (SEM) and fluorescence spectrophotometry. Synchronized contrast-enhanced ultrasound and fluorescence imaging was acquired by injecting fluorescent microbubbles into the silicone tube coupled to a self-made ultrasound/fluorescence imaging device. Ultrasound/fluorescence bi-modal in vivo imaging was acquired on the kidney of New Zealand rabbits and suckling mice. Results: The fluorescent microbubbles were hollow spheres with an averaged diameter of (1.62 ± 1.47) μm. More than 99% of these microbubbles were less than 8 μm in diameter, which met the size criteria for ultrasound contrast agents. The fluorescence emission peak of the microbubbles appeared at 632 nm, indicating that good luminescence properties of quantum dots were maintained. In vitro ultrasound/fluorescence imaging showed no echoic signal when the silicone tube was filled with saline, but there was a strong echo when filled with fluorescent microbubbles. The liquid column with fluorescent microbubbles emitted red luminescence under ultraviolet irradiation. The kidney of the rabbit was remarkably enhanced after the administration of fluorescent microbubbles. Bright fluorescence could be observed at the injection site of the suckling mice via subcutaneous injection. Conclusions: A bi-modal but single contrast agent

  3. Nonlinear response of ultrasound contrast agent microbubbles: From fundamentals to applications

    International Nuclear Information System (INIS)

    Teng Xu-Dong; Guo Xia-Sheng; Tu Juan; Zhang Dong

    2016-01-01

    Modelling and biomedical applications of ultrasound contrast agent (UCA) microbubbles have attracted a great deal of attention. In this review, we summarize a series of researches done in our group, including (i) the development of an all-in-one solution of characterizing coated bubble parameters based on the light scattering technique and flow cytometry; (ii) a novel bubble dynamic model that takes into consideration both nonlinear shell elasticity and viscosity to eliminate the dependences of bubble shell parameters on bubble size; (iii) the evaluation of UCA inertial cavitation threshold and its relationship with shell parameters; and (iv) the investigations of transfection efficiency and the reduction of cytotoxicity in gene delivery facilitated by UCAs excited by ultrasound exposures. (special topic)

  4. Thrombin-Activatable Microbubbles as Potential Ultrasound Contrast Agents for the Detection of Acute Thrombosis.

    Science.gov (United States)

    Lux, Jacques; Vezeridis, Alexander M; Hoyt, Kenneth; Adams, Stephen R; Armstrong, Amanda M; Sirsi, Shashank R; Mattrey, Robert F

    2017-11-01

    Acute deep vein thrombosis (DVT) is the formation of a blood clot in the deep veins of the body that can lead to fatal pulmonary embolism. Acute DVT is difficult to distinguish from chronic DVT by ultrasound (US), the imaging modality of choice, and is therefore treated aggressively with anticoagulants, which can lead to internal bleeding. Here we demonstrate that conjugating perfluorobutane-filled (PFB-filled) microbubbles (MBs) with thrombin-sensitive activatable cell-penetrating peptides (ACPPs) could lead to the development of contrast agents that detect acute thrombosis with US imaging. Successful conjugation of ACPP to PFB-filled MBs was confirmed by fluorescence microscopy and flow cytometry. Fluorescein-labeled ACPP was used to evaluate the efficiency of thrombin-triggered cleavage by measuring the mean fluorescence intensity of ACPP-labeled MBs (ACPP-MBs) before and after incubation at 37 °C with thrombin. Lastly, control MBs and ACPP-MBs were infused through a tube containing a clot, and US contrast enhancement was measured with or without the presence of a thrombin inhibitor after washing the clot with saline. With thrombin activity, 91.7 ± 14.2% of the signal was retained after ACPP-MB infusion and washing, whereas only 16.7 ± 4% of the signal was retained when infusing ACPP-MBs in the presence of hirudin, a potent thrombin inhibitor.

  5. Dependence of the subharmonic signal from contrast agent microbubbles on ambient pressure: A theoretical analysis.

    Science.gov (United States)

    Jiménez-Fernández, J

    2018-01-01

    This paper investigates the dependence of the subharmonic response in a signal scattered by contrast agent microbubbles on ambient pressure to provide quantitative estimations of local blood pressure. The problem is formulated by assuming a gas bubble encapsulated by a shell of finite thickness with dynamic behavior modeled by a nonlinear viscoelastic constitutive equation. For ambient overpressure compatible with the clinical range, the acoustic pressure intervals where the subharmonic signal may be detected (above the threshold for the onset and below the limit value for the first chaotic transition) are determined. The analysis shows that as the overpressure is increased, all harmonic components are displaced to higher frequencies. This displacement is significant for the subharmonic of order 1/2 and explains the increase or decrease in the subharmonic amplitude with ambient pressure described in previous works. Thus, some questions related to the monotonic dependence of the subharmonic amplitude on ambient pressure are clarified. For different acoustic pressures, quantitative conditions for determining the intervals where the subharmonic amplitude is a monotonic or non-monotonic function of the ambient pressure are provided. Finally, the influence of the ambient pressure on the subharmonic resonance frequency is analyzed.

  6. Focal hepatic lesions: contrast-enhancement patterns at pulse-inversion harmonic US using a microbubble contrast agent

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Eun-A; Yoon, Kwon-Ha; Lee, Young-Hwan; Kim, Hye-Won; Juhng, Seon-Kwan; Won, Jong-Jin [Wonkwang University, Iksan (Korea, Republic of)

    2003-12-15

    To analyze the contrast-enhancement patterns obtained at pulse-inversion harmonic imaging (PIHI) of focal hepatic lesions, and to thus determine tumor vascularity and the acoustic emission effect. We reviewed pulse-inversion images in 90 consecutive patients with focal hepatic lesions, namely hepatocellular carcinoma (HHC) (n=43), metastases (n=30), and hemangioma (n=17). Vascular and delayed phase images were obtained immediately and five minutes following the injection of a microbubble contrast agent. Tumoral vascularity at vascular phase imaging and the acoustic emission effect at delayed phase imaging were each classified as one of four patterns. Vascular phase images depicted internal vessels in 93% of HCCs, marginal vessels in 83% of metastases, and peripheral enhancement in 71% of hemangiomas. Delayed phase images showed inhomogeneous enhancement in 86% of HCCs; hypoechoic, decreased enhancement in 93% of metastases; and hypoechoic and reversed echogenicity in 65% of hemangiomas. Vascular and delayed phase enhancement patterns were associated with a specificity of 91% or greater, and 92% or greater, respectively, and with positive predictive values of 71% or greater, and 85% or greater, respectively. Contrast-enhancement patterns depicting tumoral vascularity and the acoustic emission effect at PIHI can help differentiate focal hepatic lesions.

  7. Investigation on the inertial cavitation threshold and shell properties of commercialized ultrasound contrast agent microbubbles.

    Science.gov (United States)

    Guo, Xiasheng; Li, Qian; Zhang, Zhe; Zhang, Dong; Tu, Juan

    2013-08-01

    The inertial cavitation (IC) activity of ultrasound contrast agents (UCAs) plays an important role in the development and improvement of ultrasound diagnostic and therapeutic applications. However, various diagnostic and therapeutic applications have different requirements for IC characteristics. Here through IC dose quantifications based on passive cavitation detection, IC thresholds were measured for two commercialized UCAs, albumin-shelled KangRun(®) and lipid-shelled SonoVue(®) microbubbles, at varied UCA volume concentrations (viz., 0.125 and 0.25 vol. %) and acoustic pulse lengths (viz., 5, 10, 20, 50, and 100 cycles). Shell elastic and viscous coefficients of UCAs were estimated by fitting measured acoustic attenuation spectra with Sarkar's model. The influences of sonication condition (viz., acoustic pulse length) and UCA shell properties on IC threshold were discussed based on numerical simulations. Both experimental measurements and numerical simulations indicate that IC thresholds of UCAs decrease with increasing UCA volume concentration and acoustic pulse length. The shell interfacial tension and dilatational viscosity estimated for SonoVue (0.7 ± 0.11 N/m, 6.5 ± 1.01 × 10(-8) kg/s) are smaller than those of KangRun (1.05 ± 0.18 N/m, 1.66 ± 0.38 × 10(-7) kg/s); this might result in lower IC threshold for SonoVue. The current results will be helpful for selecting and utilizing commercialized UCAs for specific clinical applications, while minimizing undesired IC-induced bioeffects.

  8. Computer-assisted quantitative assessment of power Doppler US: effects of microbubble contrast agent in the differentiation of breast tumors

    International Nuclear Information System (INIS)

    Kettenbach, Joachim; Helbich, Thomas H.; Huber, Sabine; Zuna, Ivan; Dock, Wolfgang

    2005-01-01

    Rationale and objectives: To objectively quantify the effects of a microbubble contrast agent to differentiate breast tumors with power doppler ultrasound and to compare these results with color doppler ultrasound (CD US). Methods: In 47 patients a microbubble contrast agent was injected intravenously. Computer-assisted quantitative assessment of the color pixel density was performed to evaluate the increase in Doppler signals. Results were compared to previously published results of a color Doppler ultrasound study. Results: Peak color pixel density at contrast-enhanced power Doppler ultrasound was higher for carcinomas than for benign tumors (P < 0.03). Time to peak enhancement was shorter in carcinomas than in benign tumors (P < 0.01). For both parameters, diagnostic accuracy of power Doppler ultrasound was 69 and 78%, and for color Doppler ultrasound 62 and 76%, respectively. Conclusions: Quantitative assessment of contrast-enhanced power Doppler ultrasound showed significant differences in malignant and benign breast tumors. Diagnostic accuracy of contrast-enhanced power Doppler ultrasound was higher compared to color Doppler ultrasound

  9. Targeting property and toxicity of a novel ultrasound contrast agent microbubble carrying the targeting and drug-loaded complex FA-CNTs-PTX on MCF7 cells.

    Science.gov (United States)

    Zhang, Jie; Zhang, Yu; Liu, Junxi; Li, Guozhong; Wen, Zhaohui; Zhao, Yue; Zhang, Xiangyu; Liu, Fenghua

    2017-10-01

    The application of ultrasound contrast agents not only is confined to the enhancement of ultrasound imaging but also has started to be used as a drug system for diagnosis and treatment. In this paper, Span60 and PEG1500 were used as membrane materials, and a new targeting and drug-loading multifunctional ultrasound contrast agent microbubble enveloping the FA-CNTs-PTX complex was successfully prepared by acoustic cavitation. With the breast cancer cell line MCF7 as the research target, the effects of the microbubble with FA-CNTs-PTX on the proliferation and toxicity of MCF7 cells were studied using a CCK-8 and AO/EB double-staining method. The influences of the microbubbles with FA-CNTs-PTX on the cellular morphology and apoptosis period of the MCF7 cells were detected using an inverted fluorescence microscope. The apoptosis of MCF7 cells induced by the microbubbles with FA-CNTs-PTX was investigated with flow cytometry and an annexin and PI double staining fluorescence quantitative analysis. The results indicated that the ultrasound contrast agent microbubble with FA-CNTs-PTX remarkably inhibited the proliferation of MCF7 cells, which was mainly controlled by the drug loading rate and the nanometer size of the microbubbles. Moreover, the proliferative inhibition rate of the microbubbles with FA-CNTs-PTX was related to the cell apoptosis period of MCF7 cells. Its inhibition degree on the proliferation of MCF7 cells was higher than that of the hepatoma HepG2 cells. The apoptosis rate of MCF7 cells induced by the microbubbles with FA-CNTs-PTX was higher than that of normal human umbilical vein endothelial cells (HUVECs), and the microbubbles with FA-CNTs-PTX could target the MCF7 cells. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Ex Vivo Perfusion-Simulation Measurements of Microbubbles as a Scattering Contrast Agent for Grating-Based X-Ray Dark-Field Imaging.

    Directory of Open Access Journals (Sweden)

    Astrid Velroyen

    Full Text Available The investigation of dedicated contrast agents for x-ray dark-field imaging, which exploits small-angle scattering at microstructures for contrast generation, is of strong interest in analogy to the common clinical use of high-atomic number contrast media in conventional attenuation-based imaging, since dark-field imaging has proven to provide complementary information. Therefore, agents consisting of gas bubbles, as used in ultrasound imaging for example, are of particular interest. In this work, we investigate an experimental contrast agent based on microbubbles consisting of a polyvinyl-alcohol shell with an iron oxide coating, which was originally developed for multimodal imaging and drug delivery. Its performance as a possible contrast medium for small-animal angiography was examined using a mouse carcass to realistically consider attenuating and scattering background signal. Subtraction images of dark field, phase contrast and attenuation were acquired for a concentration series of 100%, 10% and 1.3% to mimic different stages of dilution in the contrast agent in the blood vessel system. The images were compared to the gold-standard iodine-based contrast agent Solutrast, showing a good contrast improvement by microbubbles in dark-field imaging. This study proves the feasibility of microbubble-based dark-field contrast-enhancement in presence of scattering and attenuating mouse body structures like bone and fur. Therefore, it suggests a strong potential of the use of polymer-based microbubbles for small-animal dark-field angiography.

  11. Pretest Score for Predicting Microbubble Contrast Agent Use in Stress Echocardiography: A Method to Increase Efficiency in the Echo Laboratory

    Directory of Open Access Journals (Sweden)

    Mathieu Bernier

    2009-01-01

    contrast. Logistic regression models were used to evaluate the association between individual characteristics and contrast use. An 11-point score was derived from the significant characteristics. Results. Variables associated with microbubble use were age, sex, smoking, presence of multiple risk factors, bodymass index (BMI, referral for dobutamine stress echocardiography, history of coronary artery disease, and abnormal baseline electrocardiogram. All variables except BMI were given a score of 1 if present and 0 if absent; BMI was given a score of 0 to 4 according to its value. An increased score was directly proportional to increased likelihood of contrast use. The score cutoff value to optimize sensitivity and specificity was 5. Conclusions. A pretest score can be computed from information available before imaging. It may facilitate contrast agent use through early identification of patients who are likely to benefit from improved endocardial border definition.

  12. Quantitative evaluation of contrast-enhanced ultrasound after intravenous administration of a microbubble contrast agent for differentiation of benign and malignant thyroid nodules: assessment of diagnostic accuracy.

    Science.gov (United States)

    Nemec, Ursula; Nemec, Stefan F; Novotny, Clemens; Weber, Michael; Czerny, Christian; Krestan, Christian R

    2012-06-01

    To investigate the diagnostic accuracy, through quantitative analysis, of contrast-enhanced ultrasound (CEUS), using a microbubble contrast agent, in the differentiation of thyroid nodules. This prospective study enrolled 46 patients with solitary, scintigraphically non-functional thyroid nodules. These patients were scheduled for surgery and underwent preoperative CEUS with pulse-inversion harmonic imaging after intravenous microbubble contrast medium administration. Using histology as a standard of reference, time-intensity curves of benign and malignant nodules were compared by means of peak enhancement and wash-out enhancement relative to the baseline intensity using a mixed model ANOVA. ROC analysis was performed to assess the diagnostic accuracy in the differentiation of benign and malignant nodules on CEUS. The complete CEUS data of 42 patients (31/42 [73.8%] benign and 11/42 [26.2%] malignant nodules) revealed a significant difference (P benign and malignant nodules. Furthermore, based on ROC analysis, CEUS demonstrated sensitivity of 76.9%, specificity of 84.8% and accuracy of 82.6%. Quantitative analysis of CEUS using a microbubble contrast agent allows the differentiation of benign and malignant thyroid nodules and may potentially serve, in addition to grey-scale and Doppler ultrasound, as an adjunctive tool in the assessment of patients with thyroid nodules. • Contrast-enhanced ultrasound (CEUS) helps differentiate between benign and malignant thyroid nodules. • Quantitative CEUS analysis yields sensitivity of 76.9% and specificity of 84.8%. • CEUS may be a potentially useful adjunct in assessing thyroid nodules.

  13. Ultrasonic Analysis of Peptide- and Antibody-Targeted Microbubble Contrast Agents for Molecular Imaging of αvβ3-Expressing Cells

    Directory of Open Access Journals (Sweden)

    Paul A. Dayton

    2004-04-01

    Full Text Available The goal of targeted ultrasound contrast agents is to significantly and selectively enhance the detection of a targeted vascular site. In this manuscript, three distinct contrast agents targeted to the αvβ3 integrin are examined. The αvβ3 integrin has been shown to be highly expressed on metastatic tumors and endothelial cells during neovascularization, and its expression has been shown to correlate with tumor grade. Specific adhesion of these contrast agents to αvβ3-expressing cell monolayers is demonstrated in vitro, and compared with that of nontargeted agents. Acoustic studies illustrate a backscatter amplitude increase from monolayers exposed to the targeted contrast agents of up to 13-fold (22 dB relative to enhancement due to control bubbles. A linear dependence between the echo amplitude and bubble concentration was observed for bound agents. The decorrelation of the echo from adherent targeted agents is observed over successive pulses as a function of acoustic pressure and bubble density. Frequency–domain analysis demonstrates that adherent targeted bubbles exhibit high-amplitude narrowband echo components, in contrast to the primarily wideband response from free microbubbles. Results suggest that adherent targeted contrast agents are differentiable from free-floating microbubbles, that targeted contrast agents provide higher sensitivity in the detection of angiogenesis, and that conventional ultrasound imaging techniques such as signal subtraction or decorrelation detection can be used to detect integrin-expressing vasculature with sufficient signal-to-noise.

  14. Colour Doppler and microbubble contrast agent ultrasonography do not improve cancer detection rate in transrectal systematic prostate biopsy sampling.

    Science.gov (United States)

    Taverna, Gianluigi; Morandi, Giovanni; Seveso, Mauro; Giusti, Guido; Benetti, Alessio; Colombo, Piergiuseppe; Minuti, Francesco; Grizzi, Fabio; Graziotti, Pierpaolo

    2011-12-01

    What's known on the subject? and What does the study add? Transrectal gray-scale ultrasonography guided prostate biopsy sampling is the method for diagnosing prostate cancer (PC) in patients with an increased prostate specific antigen level and/or abnormal digital rectal examination. Several imaging strategies have been proposed to optimize the diagnostic value of biopsy sampling, although at the first biopsy nearly 10-30% of PC still remains undiagnosed. This study compares the PC detection rate when employing Colour Doppler ultransongraphy with or without the injection of SonoVue™ microbubble contrast agent, versus the transrectal ultrasongraphy-guided systematic biopsy sampling. The limited accuracy, sensitivity, specificity and the additional cost of using the contrast agent do not justify its routine application in PC detection. • To compare prostate cancer (PC) detection rate employing colour Doppler ultrasonography with or without SonoVue™ contrast agent with transrectal ultrasonography-guided systematic biopsy sampling. • A total of 300 patients with negative digital rectal examination and transrectal grey-scale ultrasonography, with PSA values ranging between 2.5 and 9.9 ng/mL, were randomized into three groups: 100 patients (group A) underwent transrectal ultrasonography-guided systematic bioptic sampling; 100 patients (group B) underwent colour Doppler ultrasonography, and 100 patients (group C) underwent colour Doppler ultrasonography before and during the injection of SonoVue™. • Contrast-enhanced targeted biopsies were sampled into hypervascularized areas of peripheral, transitional, apical or anterior prostate zones. • All the patients included in Groups B and C underwent a further 13 systematic prostate biopsies. The cancer detection rate was calculated for each group. • In 88 (29.3%) patients a histological diagnosis of PC was made, whereas 22 (7.4%) patients were diagnosed with high-grade prostatic intraepithelial

  15. Pulsed focused ultrasound combined with micro-bubble contrast agent can open the blood-brain barrier of gliblastoma patients and improve the efficacy of Temozolomide treatment

    Directory of Open Access Journals (Sweden)

    Qian DONG

    2017-06-01

    Full Text Available Objective This research examined the effect of microbubble contrast agent plus ultrasound on the permeability of blood-brain barrier, and explored whether it affects the efficacy of chemotherapeutic drugs on cerebral glioblastoma. Methods Wistar rats were divided into three groups to find the optimal concentration of ultrasonic contrast agent. To identify the best ultrasound mode that affected the permeability of blood brain barrier, we employed transmission electron microscopy for study of brain ultrastructure. Western blotting was used to detect the tight junction protein claudin-5. Evans blue staining of brain tissues was utilized to identify the best ultrasonic contrast agent concentration and mode. Rat glioma cells (line 9L were injected into Wistar rats. After temozolomide chemotherapy, the tumor size was measured and the tumor marker GFAP in serum was detected by ELISA. Results The best contrast agent concentration which increases permeability of BBB in rats was found to be 1ml/kg and the best ultrasound mode was intermittently- triggered pulses lasting for 10min (with interval was set at 400ms. More Evans blue passed the blood-brain barrier in ultrasonic cavitation effect group than in control group (P<0.05. After temozolomide chemotherapy, more tumor marker GFAP was detected in ultrasonic cavitation effect group than in control group (P<0.05. Conclusion The permeability of BBB was increased and more temozolomide went through BBB when the rats were subjected to intermittently triggered ultrasonic pulses and were injected at contrast agent at 1ml/kg, which could help to achieve better therapeutic efficacy for glioblastoma. DOI: 10.11855/j.issn.0577-7402.2017.05.06

  16. Phase contrast imaging of preclinical portal vein embolization with CO2 microbubbles.

    Science.gov (United States)

    Tang, Rongbiao; Yan, Fuhua; Yang, Guo Yuan; Chen, Ke Min

    2017-11-01

    Preoperative portal vein embolization (PVE) is employed clinically to avoid postoperative liver insufficiency. Animal models are usually used to study PVE in terms of mechanisms and pathophysiological changes. PVE is formerly monitored by conventional absorption contrast imaging (ACI) with iodine contrast agent. However, the side effects induced by iodine can give rise to animal damage and death. In this study, the feasibility of using phase contrast imaging (PCI) to show PVE using homemade CO 2 microbubbles in living rats has been investigated. CO 2 gas was first formed from the reaction between citric acid and sodium bicarbonate. The CO 2 gas was then encapsulated by egg white to fabricate CO 2 microbubbles. ACI and PCI of CO 2 microbubbles were performed and compared in vitro. An additional increase in contrast was detected in PCI. PCI showed that CO 2 microbubbles gradually dissolved over time, and the remaining CO 2 microbubbles became larger. By PCI, the CO 2 microbubbles were found to have certain stability, suggesting their potential use as embolic agents. CO 2 microbubbles were injected into the main portal trunk to perform PVE in living rats. PCI exploited the differences in the refractive index and facilitated clear visualization of the PVE after the injection of CO 2 microbubbles. Findings from this study suggest that homemade CO 2 microbubbles-based PCI is a novel modality for preclinical PVE research.

  17. Ultrasound contrast agents: an overview.

    Science.gov (United States)

    Cosgrove, David

    2006-12-01

    With the introduction of microbubble contrast agents, diagnostic ultrasound has entered a new era that allows the dynamic detection of tissue flow of both the macro and microvasculature. Underpinning this development is the fact that gases are compressible, and thus the microbubbles expand and contract in the alternating pressure waves of the ultrasound beam, while tissue is almost incompressible. Special software using multiple pulse sequences separates these signals from those of tissue and displays them as an overlay or on a split screen. This can be done at low acoustic pressures (MIdeveloped for myocardial perfusion. In radiology, the most important application is the liver, especially for focal disease. The approach parallels that of dynamic CT or MRI but ultrasound has the advantages of high spatial and temporal resolution. Thus, small lesions that can be indeterminate on CT can often be studied with ultrasound, and situations where the flow is very rapid (e.g., focal nodular hyperplasia where the first few seconds of arterial perfusion may be critical to making the diagnosis) are readily studied. Microbubbles linger in the extensive sinusoidal space of normal liver for several minutes whereas they wash out rapidly from metastases, which have a low vascular volume and thus appear as filling defects. The method has been shown to be as sensitive as three-phase CT. Microbubbles have clinical uses in many other applications where knowledge of the microcirculation is important (the macrocirculation can usually be assessed adequately using conventional Doppler though there are a few important situations where the signal boost given by microbubbles is useful, e.g., transcranial Doppler for evaluating vasospasm after subarachnoid haemorrhage). An important situation where demonstrating tissue devitalisation is important is in interstitial ablation of focal liver lesions: using microbubble contrast agents at the end of a procedure allows immediate evaluation of the

  18. Ultrasound contrast agents: An overview

    International Nuclear Information System (INIS)

    Cosgrove, David

    2006-01-01

    With the introduction of microbubble contrast agents, diagnostic ultrasound has entered a new era that allows the dynamic detection of tissue flow of both the macro and microvasculature. Underpinning this development is the fact that gases are compressible, and thus the microbubbles expand and contract in the alternating pressure waves of the ultrasound beam, while tissue is almost incompressible. Special software using multiple pulse sequences separates these signals from those of tissue and displays them as an overlay or on a split screen. This can be done at low acoustic pressures (MI < 0.3) so that the microbubbles are not destroyed and scanning can continue in real time. The clinical roles of contrast enhanced ultrasound scanning are expanding rapidly. They are established in echocardiography to improve endocardial border detection and are being developed for myocardial perfusion. In radiology, the most important application is the liver, especially for focal disease. The approach parallels that of dynamic CT or MRI but ultrasound has the advantages of high spatial and temporal resolution. Thus, small lesions that can be indeterminate on CT can often be studied with ultrasound, and situations where the flow is very rapid (e.g., focal nodular hyperplasia where the first few seconds of arterial perfusion may be critical to making the diagnosis) are readily studied. Microbubbles linger in the extensive sinusoidal space of normal liver for several minutes whereas they wash out rapidly from metastases, which have a low vascular volume and thus appear as filling defects. The method has been shown to be as sensitive as three-phase CT. Microbubbles have clinical uses in many other applications where knowledge of the microcirculation is important (the macrocirculation can usually be assessed adequately using conventional Doppler though there are a few important situations where the signal boost given by microbubbles is useful, e.g., transcranial Doppler for evaluating

  19. [Relevance of contrast ultrasound with microbubbles in vascular medecine].

    Science.gov (United States)

    Erdmann, Andreas; Ney, Barbara; Alatri, Adriano; Calanca, Luca; Mazzolai, Lucia

    2016-12-07

    Application of ultrasound contrast media has become a standard in diagnostic imaging in cardiology and in the characterization of focal lesions in multiple organs, especially of the liver. In the past years there was a growing body of evidence for their usefulness in vascular medicine. The development of contrast media, microbubbles with a stabilizing envelope and filled with gaz, small enough to pass through pulmonary capillaries made real-time imaging of organ perfusion possible. Ultrasound contrast media are rapidly eliminated by exhalation and can safely be administered to patients with renal failure. The objective of this review is to describe the basic principles of ultrasound contrast imaging and to inform about vascular applications of contrast ultrasound.

  20. Mechanical and dynamic characteristics of encapsulated microbubbles coupled by magnetic nanoparticles as multifunctional imaging and drug delivery agents

    Science.gov (United States)

    Guo, Gepu; Lu, Lu; Yin, Leilei; Tu, Juan; Guo, Xiasheng; Wu, Junru; Xu, Di; Zhang, Dong

    2014-11-01

    Development of magnetic encapsulated microbubble agents that can integrate multiple diagnostic and therapeutic functions is a key focus in both biomedical engineering and nanotechnology and one which will have far-reaching impact on medical diagnosis and therapies. However, properly designing multifunctional agents that can satisfy particular diagnostic/therapeutic requirements has been recognized as rather challenging, because there is a lack of comprehensive understanding of how the integration of magnetic nanoparticles to microbubble encapsulating shells affects their mechanical properties and dynamic performance in ultrasound imaging and drug delivery. Here, a multifunctional imaging contrast and in-situ gene/drug delivery agent was synthesized by coupling super paramagnetic iron oxide nanoparticles (SPIOs) into albumin-shelled microbubbles. Systematical studies were performed to investigate the SPIO-concentration-dependence of microbubble mechanical properties, acoustic scattering response, inertial cavitation activity and ultrasound-facilitated gene transfection effect. These demonstrated that, with the increasing SPIO concentration, the microbubble mean diameter and shell stiffness increased and ultrasound scattering response and inertial cavitation activity could be significantly enhanced. However, an optimized ultrasound-facilitated vascular endothelial growth factor transfection outcome would be achieved by adopting magnetic albumin-shelled microbubbles with an appropriate SPIO concentration of 114.7 µg ml-1. The current results would provide helpful guidance for future development of multifunctional agents and further optimization of their diagnostic/therapeutic performance in clinic.

  1. Mechanical and dynamic characteristics of encapsulated microbubbles coupled by magnetic nanoparticles as multifunctional imaging and drug delivery agents

    International Nuclear Information System (INIS)

    Guo, Gepu; Lu, Lu; Tu, Juan; Guo, Xiasheng; Zhang, Dong; Yin, Leilei; Wu, Junru; Xu, Di

    2014-01-01

    Development of magnetic encapsulated microbubble agents that can integrate multiple diagnostic and therapeutic functions is a key focus in both biomedical engineering and nanotechnology and one which will have far-reaching impact on medical diagnosis and therapies. However, properly designing multifunctional agents that can satisfy particular diagnostic/therapeutic requirements has been recognized as rather challenging, because there is a lack of comprehensive understanding of how the integration of magnetic nanoparticles to microbubble encapsulating shells affects their mechanical properties and dynamic performance in ultrasound imaging and drug delivery. Here, a multifunctional imaging contrast and in-situ gene/drug delivery agent was synthesized by coupling super paramagnetic iron oxide nanoparticles (SPIOs) into albumin-shelled microbubbles. Systematical studies were performed to investigate the SPIO-concentration-dependence of microbubble mechanical properties, acoustic scattering response, inertial cavitation activity and ultrasound-facilitated gene transfection effect. These demonstrated that, with the increasing SPIO concentration, the microbubble mean diameter and shell stiffness increased and ultrasound scattering response and inertial cavitation activity could be significantly enhanced. However, an optimized ultrasound-facilitated vascular endothelial growth factor transfection outcome would be achieved by adopting magnetic albumin-shelled microbubbles with an appropriate SPIO concentration of 114.7 µg ml −1 . The current results would provide helpful guidance for future development of multifunctional agents and further optimization of their diagnostic/therapeutic performance in clinic. (paper)

  2. Acoustic microstreaming due to an ultrasound contrast microbubble near a wall

    Science.gov (United States)

    Mobadersany, Nima; Sarkar, Kausik

    2017-11-01

    In an ultrasound field, in addition to the sinusoidal motion of fluid particles, particles experience a steady streaming velocity due to nonlinear second order effects. Here, we have simulated the microstreaming flow near a plane rigid wall caused by the pulsations of contrast microbubbles. Although these microbubbles were initially developed as a contrast enhancing agents for ultrasound imaging, they generate additional therapeutic effects that can be harnessed for targeted drug delivery or blood brain barrier (BBB) opening. The microbubbles have a gas core coated with a stabilizing layer of lipids or proteins. We use analytical models as well as boundary element (BEM) simulation to simulate the flow around these bubbles implementing interfacial rheology models for the coating. The microstreaming flow is characterized by two wall bounded vortices. The size of the vortices decreases with the decrease of the separation from the wall. The vortex-induced shear stress is simulated and analyzed as a function of excitation parameters and geometry. These microstreaming shear stress plays a critical role in increasing the membrane permeability facilitating drug delivery or rupturing biological tissues.

  3. Contrast agents for MRI

    International Nuclear Information System (INIS)

    Bonnemain, B.

    1994-01-01

    Contrast agents MRI (Magnetic Resonance Imaging) have been developed to improve the diagnostic information obtained by this technic. They mainly interact on T1 and T2 parameters and increase consequently normal to abnormal tissues contrast. The paramagnetic agents which mainly act on longitudinal relaxation rate (T1) are gadolinium complexes for which stability is the main parameter to avoid any release of free gadolinium. The superparamagnetic agents that decrease signal intensity by an effect on transversal relaxation rate (T2) are developed for liver, digestive and lymph node imaging. Many area of research are now opened for optimal use of present and future contrast agents in MRI. (author). 28 refs., 4 tabs

  4. Acoustic bubble sorting for ultrasound contrast agent enrichment

    NARCIS (Netherlands)

    Segers, T.J.; Versluis, Michel

    2014-01-01

    An ultrasound contrast agent (UCA) suspension contains encapsulated microbubbles with a wide size distribution, with radii ranging from 1 to 10 μm. Medical transducers typically operate at a single frequency, therefore only a small selection of bubbles will resonate to the driving ultrasound pulse.

  5. Are microbubbles free flowing tracers through the Myocardium? Comparison of indicator-dilution curves obtained from dye dilution and echo contrast using harmonic power Doppler imaging.

    Science.gov (United States)

    Tiemann, K; Schlosser, T; Pohl, C; Bimmel, D; Wietasch, G; Hoeft, A; Likungu, J; Vahlhaus, C; Kuntz, S; Nanda, N C; Becher, H; Lüderitz, B

    2000-01-01

    Harmonic power Doppler imaging (H-PDI) has been introduced into the field of contrast echocardiography as a contrast-specific imaging modality. However, there has been considerable skepticism as to whether H-PDI would be quantifiable, because it depends on the destruction of microbubbles and has more complex signal processing than gray scale imaging. The aim of the present study was to evaluate the relationship between the concentration of microbubbles and the resulting H-PDI signals even under conditions where bubble destruction is most likely. Furthermore, we evaluated whether microbubbles of Levovist freely pass the microcirculation, which is a prerequisite for the assessment of myocardial blood flow. A strong positive correlation was found between the H-PDI signals and the amount of microbubbles up to the onset of acoustic shadowing (r = 0. 968, Pgreen (ICG) in both a flow phantom and a working heart setup. The mean transit times (MTTs) through the myocardium of both agents were compared after a bolus injection into the left coronary artery. A close correlation was observed between 1/MTT and flow in both setups (r>0.98, Pgreen. We conclude that microbubbles fulfill the prerequisites of free flowing tracers through the myocardium. Furthermore, H-PDI technology allows a reliable assessment of time-concentration curves of air-filled microbubbles up to the onset of acoustic shadowing.

  6. Sonophoresis Using Ultrasound Contrast Agents: Dependence on Concentration.

    Directory of Open Access Journals (Sweden)

    Donghee Park

    Full Text Available Sonophoresis can increase skin permeability to various drugs in transdermal drug delivery. Cavitation is recognized as the predominant mechanism of sonophoresis. Recently, a new logical approach to enhance the efficiency of transdermal drug delivery was tried. It is to utilize the engineered microbubble and its resonant frequency for increase of cavitation activity. Actively-induced cavitation with low-intensity ultrasound (less than ~1 MPa causes disordering of the lipid bilayers and the formation of aqueous channels by stable cavitation which indicates a continuous oscillation of bubbles. Furthermore, the mutual interactions of microbubble determined by concentration of added bubble are also thought to be an important factor for activity of stable cavitation, even in different characteristics of drug. In the present study, we addressed the dependence of ultrasound contrast agent concentration using two types of drug on the efficiency of transdermal drug delivery. Two types of experiment were designed to quantitatively evaluate the efficiency of transdermal drug delivery according to ultrasound contrast agent concentration. First, an experiment of optical clearing using a tissue optical clearing agent was designed to assess the efficiency of sonophoresis with ultrasound contrast agents. Second, a Franz diffusion cell with ferulic acid was used to quantitatively determine the amount of drug delivered to the skin sample by sonophoresis with ultrasound contrast agents. The maximum enhancement ratio of sonophoresis with a concentration of 1:1,000 was approximately 3.1 times greater than that in the ultrasound group without ultrasound contrast agent and approximately 7.5 times greater than that in the control group. These results support our hypothesis that sonophoresis becomes more effective in transdermal drug delivery due to the presence of engineered bubbles, and that the efficiency of transdermal drug delivery using sonophoresis with

  7. Sonophoresis Using Ultrasound Contrast Agents: Dependence on Concentration.

    Science.gov (United States)

    Park, Donghee; Song, Gillsoo; Jo, Yongjun; Won, Jongho; Son, Taeyoon; Cha, Ohrum; Kim, Jinho; Jung, Byungjo; Park, Hyunjin; Kim, Chul-Woo; Seo, Jongbum

    2016-01-01

    Sonophoresis can increase skin permeability to various drugs in transdermal drug delivery. Cavitation is recognized as the predominant mechanism of sonophoresis. Recently, a new logical approach to enhance the efficiency of transdermal drug delivery was tried. It is to utilize the engineered microbubble and its resonant frequency for increase of cavitation activity. Actively-induced cavitation with low-intensity ultrasound (less than ~1 MPa) causes disordering of the lipid bilayers and the formation of aqueous channels by stable cavitation which indicates a continuous oscillation of bubbles. Furthermore, the mutual interactions of microbubble determined by concentration of added bubble are also thought to be an important factor for activity of stable cavitation, even in different characteristics of drug. In the present study, we addressed the dependence of ultrasound contrast agent concentration using two types of drug on the efficiency of transdermal drug delivery. Two types of experiment were designed to quantitatively evaluate the efficiency of transdermal drug delivery according to ultrasound contrast agent concentration. First, an experiment of optical clearing using a tissue optical clearing agent was designed to assess the efficiency of sonophoresis with ultrasound contrast agents. Second, a Franz diffusion cell with ferulic acid was used to quantitatively determine the amount of drug delivered to the skin sample by sonophoresis with ultrasound contrast agents. The maximum enhancement ratio of sonophoresis with a concentration of 1:1,000 was approximately 3.1 times greater than that in the ultrasound group without ultrasound contrast agent and approximately 7.5 times greater than that in the control group. These results support our hypothesis that sonophoresis becomes more effective in transdermal drug delivery due to the presence of engineered bubbles, and that the efficiency of transdermal drug delivery using sonophoresis with microbubbles depends on the

  8. Synthesis of Laboratory Ultrasound Contrast Agents

    Directory of Open Access Journals (Sweden)

    Jaemin Oh

    2013-10-01

    Full Text Available Ultrasound Contrast Agents (UCAs were developed to maximize reflection contrast so that organs can be seen clearly in ultrasound imaging. UCAs increase the signal to noise ratio (SNR by linear and non-linear mechanisms and thus help more accurately visualize the internal organs and blood vessels. However, the UCAs on the market are not only expensive, but are also not optimized for use in various therapeutic research applications such as ultrasound-aided drug delivery. The UCAs fabricated in this study utilize conventional lipid and albumin for shell formation and perfluorobutane as the internal gas. The shape and density of the UCA bubbles were verified by optical microscopy and Cryo SEM, and compared to those of the commercially available UCAs, Definity® and Sonovue®. The size distribution and characteristics of the reflected signal were also analyzed using a particle size analyzer and ultrasound imaging equipment. Our experiments indicate that UCAs composed of spherical microbubbles, the majority of which were smaller than 1 um, were successfully synthesized. Microbubbles 10 um or larger were also identified when different shell characteristics and filters were used. These laboratory UCAs can be used for research in both diagnoses and therapies.

  9. Real-time contrast ultrasound muscle perfusion imaging with intermediate-power imaging coupled with acoustically durable microbubbles.

    Science.gov (United States)

    Seol, Sang-Hoon; Davidson, Brian P; Belcik, J Todd; Mott, Brian H; Goodman, Reid M; Ammi, Azzdine; Lindner, Jonathan R

    2015-06-01

    There is growing interest in limb contrast-enhanced ultrasound (CEU) perfusion imaging for the evaluation of peripheral artery disease. Because of low resting microvascular blood flow in skeletal muscle, signal enhancement during limb CEU is prohibitively low for real-time imaging. The aim of this study was to test the hypothesis that this obstacle can be overcome by intermediate- rather than low-power CEU when performed with an acoustically resilient microbubble agent. Viscoelastic properties of Definity and Sonazoid were assessed by measuring bulk modulus during incremental increases in ambient pressure to 200 mm Hg. Comparison of in vivo microbubble destruction and signal enhancement at a mechanical index (MI) of 0.1 to 0.4 was performed by sequential reduction in pulsing interval from 10 to 0.05 sec during limb CEU at 7 MHz in mice and 1.8 MHz in dogs. Destruction was also assessed by broadband signal generation during passive cavitation detection. Real-time CEU perfusion imaging with destruction-replenishment was then performed at 1.8 MHz in dogs using an MI of 0.1, 0.2, or 0.3. Sonazoid had a higher bulk modulus than Definity (66 ± 12 vs 29 ± 2 kPa, P = .02) and exhibited less inertial cavitation (destruction) at MIs ≥ 0.2. On in vivo CEU, maximal signal intensity increased incrementally with MI for both agents and was equivalent between agents except at an MI of 0.1 (60% and 85% lower for Sonazoid at 7 and 1.8 MHz, respectively, P power imaging coupled with a durable microbubble contrast agent. Copyright © 2015 American Society of Echocardiography. All rights reserved.

  10. New MR contrast agent

    International Nuclear Information System (INIS)

    Grossman, C.D.; Subramanian, G.; Schneider, R.; Szeverenyi, N.E.; Rosenbaum, A.M.; Gagne, G.; Tillapaugh-Fay, G.; Berlin, R.; Ritter-Hrncirik, C.; Yu, S.

    1990-01-01

    This paper evaluates an MR contrast agent-meglumine tris-(2,6-dicarboxypyridine) gadolinium (III) or gadolinium dipicolinate (Gd-DPC)-produced in-house. Rats were anesthetized with pentobarbital. For renal imaging, bowel motion artifact was minimized with glucagon (0.014 mg/kg, intravenous (IV)). Enhanced images were generated on a 2-T chemical shift imaging system with a 31-cm horizontal bore magnet after IV injection of Gd-DPC (100 μM/kg). Coronal sections of the kidneys and sagittal sections of the brain, 2 mm thick, were made. Six to eight excitations and 128 or 356 phase-encoding steps were used for each image. Control animals were injected with equivalent doses of gadopentetate dimeglumine

  11. Jetting of a ultrasound contrast microbubble near a rigid wall

    Science.gov (United States)

    Sarkar, Kausik; Mobadersany, Nima

    2017-11-01

    Micron sized gas-bubbles coated with a stabilizing shell of lipids or proteins, are used as contrast enhancing agents for ultrasound imaging. However, they are increasingly being explored for novel applications in drug delivery through a process called sonoporation, the reversible permeabilization of the cell membrane. Under sufficiently strong acoustic excitations, bubbles form a jet and collapse near a wall. The jetting of free bubbles has been extensively studied by boundary element method (BEM). Here, for the first time, we implemented a rigorous interfacial rheological model of the shell into BEM and investigated the jet formation. The code has been carefully validated against past results. Increasing shell elasticity decreases the maximum bubble volume and the collapse time, while the jet velocity increases. The shear stress on the wall is computed and analyzed. A phase diagram as functions of excitation pressure and wall separation describes jet formation. Effects of shell elasticity and frequency on the phase diagram are investigated. Partially supported by National Science Foundation.

  12. Tumor Vessel Compression Hinders Perfusion of Ultrasonographic Contrast Agents

    Directory of Open Access Journals (Sweden)

    Mirco Galiè

    2005-05-01

    Full Text Available Contrast-enhanced ultrasound (CEUS is an advanced approach to in vivo assessment of tumor vascularity and is being increasingly adopted in clinical oncology. It is based on 1- to 10 μm-sized gas microbubbles, which can cross the capillary beds of the lungs and are effective echo enhancers. It is known that high cell density, high transendothelial fluid exchange, and poorly functioning lymphatic circulation all provoke solid stress, which compresses vessels and drastically reduces tumor blood flow. Given their size, we supposed that the perfusion of microbubbles is affected by anatomic features of tumor vessels more than are contrast agents traditionally used in dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI. Here, we compared dynamic information obtained from CEUS and DCE-MRI on two experimental tumor models exhibiting notable differences in vessel anatomy. We found that tumors with small, flattened vessels show a much higher resistance to microbubble perfusion than to MRI contrast agents, and appear scarcely vascularized at CEUS examination, despite vessel volume adequate for normal function. Thus, whereas CEUS alone could induce incorrect diagnosis when tumors have small or collapsed vessels, integrated analysis using CEUS and DCE-MRI allows in vivo identification of tumors with a vascular profile frequently associated with malignant phenotypes.

  13. Tumor Vessel Compression Hinders Perfusion of Ultrasonographic Contrast Agents1

    Science.gov (United States)

    Galiè, Mirco; D'Onofrio, Mirko; Montani, Maura; Amici, Augusto; Calderan, Laura; Marzola, Pasquina; Benati, Donatella; Merigo, Flavia; Marchini, Cristina; Sbarbati, Andrea

    2005-01-01

    Abstract Contrast-enhanced ultrasound (CEUS) is an advanced approach to in vivo assessment of tumor vascularity and is being increasingly adopted in clinical oncology. It is based on 1- to 10 µm-sized gas microbubbles, which can cross the capillary beds of the lungs and are effective echo enhancers. It is known that high cell density, high transendothelial fluid exchange, and poorly functioning lymphatic circulation all provoke solid stress, which compresses vessels and drastically reduces tumor blood flow. Given their size, we supposed that the perfusion of microbubbles is affected by anatomic features of tumor vessels more than are contrast agents traditionally used in dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI). Here, we compared dynamic information obtained from CEUS and DCE-MRI on two experimental tumor models exhibiting notable differences in vessel anatomy. We found that tumors with small, flattened vessels show a much higher resistance to microbubble perfusion than to MRI contrast agents, and appear scarcely vascularized at CEUS examination, despite vessel volume adequate for normal function. Thus, whereas CEUS alone could induce incorrect diagnosis when tumors have small or collapsed vessels, integrated analysis using CEUS and DCE-MRI allows in vivo identification of tumors with a vascular profile frequently associated with malignant phenotypes. PMID:15967105

  14. Acoustic bubble sorting for ultrasound contrast agent enrichment.

    Science.gov (United States)

    Segers, Tim; Versluis, Michel

    2014-05-21

    An ultrasound contrast agent (UCA) suspension contains encapsulated microbubbles with a wide size distribution, with radii ranging from 1 to 10 μm. Medical transducers typically operate at a single frequency, therefore only a small selection of bubbles will resonate to the driving ultrasound pulse. Thus, the sensitivity can be improved by narrowing down the size distribution. Here, we present a simple lab-on-a-chip method to sort the population of microbubbles on-chip using a traveling ultrasound wave. First, we explore the physical parameter space of acoustic bubble sorting using well-defined bubble sizes formed in a flow-focusing device, then we demonstrate successful acoustic sorting of a commercial UCA. This novel sorting strategy may lead to an overall improvement of the sensitivity of contrast ultrasound by more than 10 dB.

  15. Microbubbles for medical applications

    NARCIS (Netherlands)

    Segers, T.J.; de Jong, N.; Lohse, Detlef; Versluis, Michel; van den Berg, A.; Segerink, L.

    2015-01-01

    Ultrasound contrast agent (UCA) suspensions contain encapsulated microbubbles with radii ranging from 1 to 10 micrometers. The bubbles oscillate to the driving ultrasound pulse generating harmonics of the driving ultrasound frequency. This feature allows for the discrimination of non-linear bubble

  16. Usage of CO2 microbubbles as flow-tracing contrast media in X-ray dynamic imaging of blood flows.

    Science.gov (United States)

    Lee, Sang Joon; Park, Han Wook; Jung, Sung Yong

    2014-09-01

    X-ray imaging techniques have been employed to visualize various biofluid flow phenomena in a non-destructive manner. X-ray particle image velocimetry (PIV) was developed to measure velocity fields of blood flows to obtain hemodynamic information. A time-resolved X-ray PIV technique that is capable of measuring the velocity fields of blood flows under real physiological conditions was recently developed. However, technical limitations still remained in the measurement of blood flows with high image contrast and sufficient biocapability. In this study, CO2 microbubbles as flow-tracing contrast media for X-ray PIV measurements of biofluid flows was developed. Human serum albumin and CO2 gas were mechanically agitated to fabricate CO2 microbubbles. The optimal fabricating conditions of CO2 microbubbles were found by comparing the size and amount of microbubbles fabricated under various operating conditions. The average size and quantity of CO2 microbubbles were measured by using a synchrotron X-ray imaging technique with a high spatial resolution. The quantity and size of the fabricated microbubbles decrease with increasing speed and operation time of the mechanical agitation. The feasibility of CO2 microbubbles as a flow-tracing contrast media was checked for a 40% hematocrit blood flow. Particle images of the blood flow were consecutively captured by the time-resolved X-ray PIV system to obtain velocity field information of the flow. The experimental results were compared with a theoretically amassed velocity profile. Results show that the CO2 microbubbles can be used as effective flow-tracing contrast media in X-ray PIV experiments.

  17. Changes in tumor vascularity precede microbubble contrast accumulation deficit in the process of dedifferentiation of hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Maruyama, Hitoshi; Takahashi, Masanori; Ishibashi, Hiroyuki; Okabe, Shinichiro; Yoshikawa, Masaharu; Yokosuka, Osamu

    2010-01-01

    Purpose: To elucidate the changes in tumor vascularity and microbubble accumulation on contrast-enhanced sonograms, in relation to the dedifferentiation of hepatocellular carcinoma (HCC). Materials and methods: This prospective study enrolled 10 patients with histologically proven HCC (14.4-39.0 mm, 26.1 ± 7.4) showing nodule-in-nodule appearance upon contrast-enhanced computed tomography. Contrast-enhanced ultrasound was performed by harmonic imaging under a low mechanical index (0.22-0.25) during the vascular phase (agent injection to 1 min) and late phase (15 min) following the injection of Sonazoid TM (0.0075 ml/kg). Contrast enhancement in the inner and outer nodules was assessed in comparison with that in adjacent liver parenchyma as hyper-, iso-, or hypo-enhanced. Results: Vascular-phase enhancement of all 10 inner nodules was hyper-enhanced, and that of outer nodules was hyper-enhanced in 3, iso-enhanced in 2, and hypo-enhanced in 5. Late-phase enhancement of inner nodules was hypo-enhanced in 8 and iso-enhanced in 2. Furthermore, late-phase enhancement of outer nodules was iso-enhanced in the 7 lesions that showed iso- or hypo-enhancement in the vascular phase, and hypo-enhanced in the 3 with hyper-enhancement in the vascular phase. Late-phase hypo-enhancement was significantly more frequent in the nodules showing early-phase hyper-enhancement (11/13) than in the nodules showing early-phase iso- or hypo-enhancement (0/7) in both the inner and outer nodules. Conclusion: Dedifferentiation of HCC may be accompanied by changes in tumor vascularity prior to a reduction in microbubble accumulation. Observation of the vascular phase may be more useful than late-phase imaging for the early recognition of HCC dedifferentiation when using contrast-enhanced ultrasound with Sonazoid.

  18. Molecular evaluation of thrombosis using X-ray phase contrast imaging with microbubbles targeted to P-selectin in mice

    International Nuclear Information System (INIS)

    Tang, Rongbiao; Chai, Wei-Min; Yan, Fuhua; Chen, Ke-Min; Yang, Guo-Yuan

    2016-01-01

    X-ray phase contrast imaging (PCI) provides excellent image contrast by utilizing the phase shift. The introduction of microbubbles into tissues can cause a phase shift to make microbubbles visibly identified on PCI. In this study, we assessed the feasibility of targeted microbubble-based PCI for the detection of thrombosis. The absorption and phase contrast images of P-selectin-targeted microbubbles (MB P ) were obtained and compared in vitro. MB P , control IgG-targeted microbubbles (MB C ), and unbound microbubbles (MB U ) were tested for binding specificity on thrombi expressing P-selectin. MB P were used as molecular PCI probes to evaluate P-selectin expression in a mouse model of arteriovenous shunt thrombosis that was created using PE tubes in the bypass outside of the mouse body. PCI clearly showed the microbubbles not viewable via absorption contrast imaging (ACI). In vitro attachment of MB P (91.60 ± 11.63) to thrombi was significantly higher than attachment of MB C (17.80 ± 4.02, P < 0.001) or MB U (9.80 ± 2.59, P < 0.001). In the mouse model of arteriovenous shunt thrombosis, the binding affinity of MB P (15.50 ± 6.25) was significantly greater than that of MB C (0.50 ± 0.84, P < 0.001) or MB U (0.33 ± 0.52, P < 0.001). Our results indicate that molecular PCI may be considered as a novel and promising imaging modality for the investigation of thrombosis. (orig.)

  19. Experimental investigations of nonlinearities and destruction mechanisms of an experimental phospholipid-based ultrasound contrast agent.

    Science.gov (United States)

    Casciaro, Sergio; Palmizio Errico, Rosa; Errico, Rosa Palmizio; Conversano, Francesco; Demitri, Christian; Distante, Alessandro

    2007-02-01

    We sought to characterize the acoustical behavior of the experimental ultrasound contrast agent BR14 by determining the acoustic pressure threshold above which nonlinear oscillation becomes significant and investigating microbubble destruction mechanisms. We used a custom-designed in vitro setup to conduct broadband attenuation measurements at 3.5 MHz varying acoustic pressure (range, 50-190 kPa). We also performed granulometric analyses on contrast agent solutions to accurately measure microbubble size distribution and to evaluate insonification effects. Attenuation did not depend on acoustic pressure less than 100 kPa, indicating this pressure as the threshold for the appearance of microbubble nonlinear behavior. At the lowest excitation amplitude, attenuation increased during insonification, while, at higher excitation levels, the attenuation decreased over time, indicating microbubble destruction. The destruction rate changed with pressure amplitude suggesting different destruction mechanisms, as it was confirmed by granulometric analysis. Microbubbles showed a linear behavior until 100 kPa, whereas beyond this value significant nonlinearities occurred. Observed destruction phenomena seem to be mainly due to gas diffusion and bubble fragmentation mechanisms.

  20. Contrast-enhanced voiding urosonography: in vitro evaluation of a second-generation ultrasound contrast agent for in vivo optimization.

    Science.gov (United States)

    Back, Susan J; Edgar, J Christopher; Canning, Douglas A; Darge, Kassa

    2015-09-01

    Pediatric contrast-enhanced ultrasound (CEUS) is primarily performed outside the United States where a track record for safety in intravenous and intravesical applications has been established. Contrast-enhanced voiding urosonography (ceVUS) has also been shown to have a much higher rate of vesicoureteral reflux detection compared to voiding cystourethrography. US contrast agents available in the United States differ from those abroad. Optison® (GE Healthcare, Princeton, NJ) is such an US contrast agent. While Optison® has similar characteristics to other second-generation agents, it has never been used for ceVUS. In vitro optimization of dose and imaging parameters as well as assessment of contrast visualization when delivered in conditions similar to ceVUS are necessary starting points prior to in vivo applications. To optimize the intravesical use of Optison® in vitro for ceVUS before its use in pediatric studies. The experimental design simulated intravesical use. Using 9- and 12-MHz linear transducers, we scanned 20-mL syringes varying mechanical index, US contrast agent concentration (0.25%, 0.5%, 1.0%), solvent (saline, urine, radiographic contrast agent) and time out of refrigeration. We evaluated mechanical index settings and contrast duration, optimized the contrast dose, measured the effect of urine and radiographic contrast agent, and the impact of length of time of contrast outside of the refrigerator on US contrast appearance. We scanned 50-ml saline bags to assess the appearance and duration of US contrast with different delivery systems (injection vs. infusion). Consistent contrast visualization was achieved at a mechanical index of 0.06-0.17 and 0.11-0.48 for the L9 and L12 MHz transducers (P contrast visualization of the microbubbles with a higher transducer frequency. The lowest mechanical index for earliest visible microbubble destruction was 0.21 for the 9 MHz and 0.39 for the 12 MHz (P contrast agent volume to bladder filling was the

  1. Microbubble Cavitation Imaging

    OpenAIRE

    Vignon, Francois; Shi, William T.; Powers, Jeffry E.; Everbach, E. Carr; Liu, Jinjin; Gao, Shunji; Xie, Feng; Porter, Thomas R.

    2013-01-01

    Ultrasound cavitation of microbubble contrast agents has a potential for therapeutic applications such as sonothrombolysis (STL) in acute ischemic stroke. For safety, efficacy, and reproducibility of treatment, it is critical to evaluate the cavitation state (moderate oscillations, stable cavitation, and inertial cavitation) and activity level in and around a treatment area. Acoustic passive cavitation detectors (PCDs) have been used to this end but do not provide spatial information.

  2. Microbubble acoustic signatures: bubble deflation

    NARCIS (Netherlands)

    ten Brinke, G.A.; Slump, Cornelis H.

    2006-01-01

    Ultrasound Contrast Agents (UCAs) are used in medical imaging to enhance the visibility of structures, especially blood vessels and the liver. An example application of UCAs is the detection and classification of tumors. The most common UCA consist of microbubbles, which have pronounced non-linear

  3. Design and Control of Functional Microbubbles for Medical Applications of Ultrasound

    Science.gov (United States)

    Takagi, Shu; Osaki, Taichi; Ariyoshi, Takuya; Azuma, Takashi; Ichiyanagi, Mitsuhisa; Kinefuchi, Ikuya

    2015-11-01

    Microbubbles are used as a contrast agent for ultrasound diagnosis. It is also expected to be use for the treatment. One of the possible applications is microbubble DDS. For that purpose, microbubbles need to be well-controlled for the generating process and manipulation. In this talk, for the design and control of the functional microbubbles, an experimental study on generation and surface modification of microbubbles are explained. Using a T-junction type microchannel, small bubbles about 5 μm size are successfully generated. For the surface modification, Biotin-coated microbubbles are tried to adhere the Avidin-coated wall. Furthermore, the manipulation of the microbubbles using ultrasound is also discussed. Plane-wave and focused ultrasound is used to manipulate a microbubble and bubble clusters. The experimental results are shown in the presentation. Supported by JSPS KAKENHI Grant Number 15K13865.

  4. Real-Time Two-Dimensional Imaging of Microbubble Cavitation

    NARCIS (Netherlands)

    Vignon, F.; Shi, W.T.; Powers, J.E.; Liu, J.; Drvol, L.; Lof, J.; Everbach, C.; Gao, S.; Xie, F.; Porter, T.

    2011-01-01

    Ultrasound cavitation of microbubble contrast agents has a potentialfor therapeutic applications, including sonothrombolysis in acute ischemic stroke. For safety, efficacy, and reproducibility of treatment, it is critical to evaluate the cavitation state (e.g. stable versus inertial forms of

  5. Quantitative investigation of the edge enhancement in in-line phase contrast projections and tomosynthesis provided by distributing microbubbles on the interface between two tissues: a phantom study

    Science.gov (United States)

    Wu, Di; Donovan Wong, Molly; Li, Yuhua; Fajardo, Laurie; Zheng, Bin; Wu, Xizeng; Liu, Hong

    2017-12-01

    The objective of this study was to quantitatively investigate the ability to distribute microbubbles along the interface between two tissues, in an effort to improve the edge and/or boundary features in phase contrast imaging. The experiments were conducted by employing a custom designed tissue simulating phantom, which also simulated a clinical condition where the ligand-targeted microbubbles are self-aggregated on the endothelium of blood vessels surrounding malignant cells. Four different concentrations of microbubble suspensions were injected into the phantom: 0%, 0.1%, 0.2%, and 0.4%. A time delay of 5 min was implemented before image acquisition to allow the microbubbles to become distributed at the interface between the acrylic and the cavity simulating a blood vessel segment. For comparison purposes, images were acquired using three system configurations for both projection and tomosynthesis imaging with a fixed radiation dose delivery: conventional low-energy contact mode, low-energy in-line phase contrast and high-energy in-line phase contrast. The resultant images illustrate the edge feature enhancements in the in-line phase contrast imaging mode when the microbubble concentration is extremely low. The quantitative edge-enhancement-to-noise ratio calculations not only agree with the direct image observations, but also indicate that the edge feature enhancement can be improved by increasing the microbubble concentration. In addition, high-energy in-line phase contrast imaging provided better performance in detecting low-concentration microbubble distributions.

  6. Thermal dependence of ultrasound contrast agents scattering efficiency for echographic imaging techniques

    Science.gov (United States)

    Biagioni, Angelo; Bettucci, Andrea; Passeri, Daniele; Alippi, Adriano

    2015-06-01

    Ultrasound contrast agents are used in echographic imaging techniques to enhance image contrast. In addition, they may represent an interesting solution to the problem of non-invasive temperature monitoring inside the human body, based on some thermal variations of their physical properties. Contrast agents, indeed, are inserted into blood circulation and they reach the most important organs inside the human body; consequently, any thermometric property that they may possess, could be exploited for realizing a non-invasive thermometer. They essentially are a suspension of microbubbles containing a gas enclosed in a phospholipid membrane; temperature variations induce structural modifications of the microbubble phospholipid shell, thus causing thermal dependence of contrast agent's elastic characteristics. In this paper, the acoustic scattering efficiency of a bulk suspension of of SonoVue® (Bracco SpA Milan, Italy) has been studied using a pulse-echo technique in the frequency range 1-17 MHz, as it depends upon temperatures between 25 and 65°C. Experimental data confirm that the ultrasonic attenuation coefficient of SonoVue® depends on temperature between 25 and 60°C. Chemical composition of the bubble shell seem to support the hypothesis that a phase transition in the microstructure of lipid-coated microbubbles could play a key role in explaining such effect.

  7. Photoacoustic/ultrasound dual-modality contrast agent and its application to thermotherapy.

    Science.gov (United States)

    Wang, Yu-Hsin; Liao, Ai-Ho; Chen, Jui-Hao; Wang, Churng-Ren Chris; Li, Pai-Chi

    2012-04-01

    This study investigates a photoacoustic/ultrasound dual-modality contrast agent, including extending its applications from image-contrast enhancement to combined diagnosis and therapy with site-specific targeting. The contrast agent comprises albumin-shelled microbubbles with encapsulated gold nanorods (AuMBs). The gas-filled microbubbles, whose diameters range from submicrometer to several micrometers, are not only echogenic but also can serve as drug-delivery vehicles. The gold nanorods are used to enhance the generation of both photoacoustic and photothermal signals. The optical absorption peak of the gold nanorods is tuned to 760 nm and is invariant after microbubble encapsulation. Dual-modality contrast enhancement is first described here, and the applications to cellular targeting and laser-induced thermotherapy in a phantom are demonstrated. Photoacoustic imaging can be used to monitor temperature increases during the treatment. The targeting capability of AuMBs was verified, and the temperature increased by 26°C for a laser power of 980 mW, demonstrating the potential of combined diagnosis and therapy with the dual-modality agent. Targeted photo- or acoustic-mediated delivery is also possible.

  8. Nonlinear Dynamics of a Bubble Contrast Agent Oscillating near an Elastic Wall

    Science.gov (United States)

    Garashchuk, Ivan R.; Sinelshchikov, Dmitry I.; Kudryashov, Nikolay A.

    2018-05-01

    Contrast agent microbubbles, which are encapsulated gas bubbles, are widely used to enhance ultrasound imaging. There are also several new promising applications of the contrast agents such as targeted drug delivery and noninvasive therapy. Here we study three models of the microbubble dynamics: a nonencapsulated bubble oscillating close to an elastic wall, a simple coated bubble and a coated bubble near an elastic wall.We demonstrate that complex dynamics can occur in these models. We are particularly interested in the multistability phenomenon of bubble dynamics. We show that coexisting attractors appear in all of these models, but for higher acoustic pressures for the models of an encapsulated bubble.We demonstrate how several tools can be used to localize the coexisting attractors. We provide some considerations why the multistability can be undesirable for applications.

  9. Microbubble Cavitation Imaging

    Science.gov (United States)

    Vignon, Francois; Shi, William T.; Powers, Jeffry E.; Everbach, E. Carr; Liu, Jinjin; Gao, Shunji; Xie, Feng; Porter, Thomas R.

    2014-01-01

    Ultrasound cavitation of microbubble contrast agents has a potential for therapeutic applications such as sonothrombolysis (STL) in acute ischemic stroke. For safety, efficacy, and reproducibility of treatment, it is critical to evaluate the cavitation state (moderate oscillations, stable cavitation, and inertial cavitation) and activity level in and around a treatment area. Acoustic passive cavitation detectors (PCDs) have been used to this end but do not provide spatial information. This paper presents a prototype of a 2-D cavitation imager capable of producing images of the dominant cavitation state and activity level in a region of interest. Similar to PCDs, the cavitation imaging described here is based on the spectral analysis of the acoustic signal radiated by the cavitating microbubbles: ultraharmonics of the excitation frequency indicate stable cavitation, whereas elevated noise bands indicate inertial cavitation; the absence of both indicates moderate oscillations. The prototype system is a modified commercially available ultrasound scanner with a sector imaging probe. The lateral resolution of the system is 1.5 mm at a focal depth of 3 cm, and the axial resolution is 3 cm for a therapy pulse length of 20 µs. The maximum frame rate of the prototype is 2 Hz. The system has been used for assessing and mapping the relative importance of the different cavitation states of a microbubble contrast agent. In vitro (tissue-mimicking flow phantom) and in vivo (heart, liver, and brain of two swine) results for cavitation states and their changes as a function of acoustic amplitude are presented. PMID:23549527

  10. Evaluation of high frequency ultrasound methods and contrast agents for characterising tumor response to anti-angiogenic treatment

    Energy Technology Data Exchange (ETDEWEB)

    Rix, Anne, E-mail: arix@ukaachen.de [Department of Experimental Molecular Imaging, Pauwelsstrasse 30, 52074 Aachen, RWTH-Aachen University, Aachen (Germany); Lederle, Wiltrud, E-mail: wlederle@ukaachen.de [Department of Experimental Molecular Imaging, Pauwelsstrasse 30, 52074 Aachen, RWTH-Aachen University, Aachen (Germany); Siepmann, Monica, E-mail: monica.siepmann@rub.de [Department of Medical Engineering, Universitätstraße 150, 44780 Bochum, Ruhr-University Bochum, Bochum (Germany); Fokong, Stanley, E-mail: sfokong@ukaachen.de [Department of Experimental Molecular Imaging, Pauwelsstrasse 30, 52074 Aachen, RWTH-Aachen University, Aachen (Germany); Behrendt, Florian F., E-mail: fbehrendt@ukaachen.de [Department of Nuclear Medicine, Pauwelsstrasse 30, 52074 Aachen, RWTH-Aachen University, Aachen (Germany); Bzyl, Jessica, E-mail: jbzyl@ukaachen.de [Department of Experimental Molecular Imaging, Pauwelsstrasse 30, 52074 Aachen, RWTH-Aachen University, Aachen (Germany); Grouls, Christoph, E-mail: cgrouls@ukaachen.de [Department of Experimental Molecular Imaging, Pauwelsstrasse 30, 52074 Aachen, RWTH-Aachen University, Aachen (Germany); Kiessling, Fabian, E-mail: fkiessling@ukaachen.de [Department of Experimental Molecular Imaging, Pauwelsstrasse 30, 52074 Aachen, RWTH-Aachen University, Aachen (Germany); Palmowski, Moritz, E-mail: mpalmowski@ukaachen.de [Department of Experimental Molecular Imaging, Pauwelsstrasse 30, 52074 Aachen, RWTH-Aachen University, Aachen (Germany); Department of Nuclear Medicine, Pauwelsstrasse 30, 52074 Aachen, RWTH-Aachen University, Aachen (Germany)

    2012-10-15

    Purpose: To compare non-enhanced and contrast-enhanced high-frequency 3D Doppler ultrasound with contrast-enhanced 2D and 3D B-mode imaging for assessing tumor vascularity during antiangiogenic treatment using soft-shell and hard-shell microbubbles. Materials and methods: Antiangiogenic therapy effects (SU11248) on vascularity of subcutaneous epidermoid-carcinoma xenografts (A431) in female CD1 nude mice were investigated longitudinally using non-enhanced and contrast-enhanced 3D Doppler at 25 MHz. Additionally, contrast-enhanced 2D and 3D B-mode scans were performed by injecting hard-shell (poly-butyl-cyanoacrylate-based) and soft-shell (phospholipid-based) microbubbles. Suitability of both contrast agents for high frequency imaging and the sensitivity of the different ultrasound methods to assess early antiangiogenic therapy effects were investigated. Ultrasound data were validated by immunohistology. Results: Hard-shell microbubbles induced higher signal intensity changes in tumors than soft-shell microbubbles in 2D B-mode measurements (424 ± 7 vs. 169 ± 8 A.U.; p < 0.01). In 3D measurements, signals of soft-shell microbubbles were hardly above the background (5.48 ± 4.57 vs. 3.86 ± 2.92 A.U.), while signals from hard-shell microbubbles were sufficiently high (30.5 ± 8.06 A.U). Using hard-shell microbubbles 2D and 3D B-mode imaging depicted a significant decrease in tumor vascularity during antiangiogenic therapy from day 1 on. Using soft-shell microbubbles significant therapy effects were observed at day 4 after therapy in 2D B-mode imaging but could not be detected in the 3D mode. With non-enhanced and contrast-enhanced Doppler imaging significant differences between treated and untreated tumors were found from day 2 on. Conclusion: Hard-shell microbubble-enhanced 2D and 3D B-mode ultrasound achieved highest sensitivity for assessing therapy effects on tumor vascularisation and were superior to B-mode ultrasound with soft-shell microbubbles and to Doppler

  11. Renal perfusion image using harmonic ultrasound with microbble contrast agent: preliminary study

    International Nuclear Information System (INIS)

    Kim, Jung Hoon; Choi, Jae Ho; Han, Dong Chul; Lee, Hi Bahl; Choi, Deuk Lin; Eun, Hyo Won; Lee, Hun Jae

    2003-01-01

    To compare, in terms of their feasibility and normal range, 99m Tc-DTPA renal perfusion imaging and renal perfusion imaging using harmonic ultrasound (US) with a microbubble contrast agent for the evaluation of renal perfusion after renal transplantation. During a six-month period, thirty patients who had received a renal transplant underwent both 99m Tc-DTPA renal perfusion imaging and renal perfusion imaging using harmonic US with a microbubble contrast agent. Sonographic renal perfusion images were obtained before and after a bolus injection of the microbubble contrast agent Levovist TM (SH U 5084; Schering AG, Berlin, Germany) every 3 seconds for 3 minutes. Sonographic renal perfusion images were converted into a renal perfusion curve by a computer program and T peak of the curve thus obtained was compared with that of the 99m Tc-DTPA curve. Average T peak of the 99m Tc-DTPA renal perfusion curve was 16.2 seconds in the normal group and 39.6 seconds in the delayed perfusion group, while average T peak of the sonographic renal perfusion curve was 23.7 seconds and 46.2 seconds, respectively. T peak of the sonographic renal perfusion curve showed a good correlation with that of the 99m Tc-DTPA curve (correlation coefficient=0.8209; p=0.0001). The cut-off value of T peak of the sonographic renal perfusion curve was 35 seconds (sensitivity=90%, specificity=95%). In patients who have received a renal transplant, the findings of renal perfusion imaging using harmonic US with a microbubble contrast agent show close correlation with those of 99m Tc-DTPA renal perfusion imaging. The optimal cut-off value of T peak of the sonographic renal perfusion curve was 35 seconds

  12. Effects of microchannel confinement on acoustic vaporisation of ultrasound phase change contrast agents

    Science.gov (United States)

    Lin, Shengtao; Zhang, Ge; Hau Leow, Chee; Tang, Meng-Xing

    2017-09-01

    The sub-micron phase change contrast agent (PCCA) composed of a perfluorocarbon liquid core can be activated into gaseous state and form stable echogenic microbubbles for contrast-enhanced ultrasound imaging. It has shown great promise in imaging microvasculature, tumour microenvironment, and cancer cells. Although PCCAs have been extensively studied for different diagnostic and therapeutic applications, the effect of biologically geometrical confinement on the acoustic vaporisation of PCCAs is still not clear. We have investigated the difference in PCCA-produced ultrasound contrast enhancement after acoustic activation with and without a microvessel confinement on a microchannel phantom. The experimental results indicated more than one-order of magnitude less acoustic vaporisation in a microchannel than that in a free environment taking into account the attenuation effect of the vessel on the microbubble scattering. This may provide an improved understanding in the applications of PCCAs in vivo.

  13. Ultrafast 2-dimensional image monitoring and array-based passive cavitation detection for ultrasound contrast agent destruction in a variably sized region.

    Science.gov (United States)

    Xu, Shanshan; Hu, Hong; Jiang, Hujie; Xu, Zhi'an; Wan, Mingxi

    2014-11-01

    A combined approach was proposed, based on programmable ultrasound equipment, to simultaneously monitor surviving microbubbles and detect cavitation activity during microbubble destruction in a variably sized region for use in ultrasound contrast agent (UCA)-enhanced therapeutic ultrasound applications. A variably sized focal region wherein the acoustic pressure was above the UCA fragmentation threshold was synthesized at frequencies of 3, 4, 5, and 6 MHz with a linear broadband imaging probe. The UCAs' temporal and spatial distribution during the microbubbles' destruction was monitored in a 2-dimensional imaging plane at 5 MHz and a frame rate of 400 Hz, and simultaneously, broadband noise emissions during the microbubbles' fragmentation were extracted by using the backscattered signals produced by the focused release bursts (ie, destruction pulses) themselves. Afterward, the temporal evolution of broadband noise emission, the surviving microbubbles in a region of interest (ROI), and the destruction area in a static UCA suspension were computed. Then the inertial cavitation dose, destruction rate of microbubbles in the ROI, and area of the destruction region were determined. It was found that an increasing pulse length and a decreasing transmit aperture and excitation frequency were correlated with an increased inertial cavitation dose, microbubble destruction rate, and destruction area. Furthermore, it was obvious that the microbubble destruction rate was significantly correlated with the inertial cavitation dose (P cavitation dose could be regulated by manipulating the transmission parameters. © 2014 by the American Institute of Ultrasound in Medicine.

  14. Rest-Stress Limb Perfusion Imaging in Humans with Contrast Ultrasound Using Intermediate-Power Imaging and Microbubbles Resistant to Inertial Cavitation.

    Science.gov (United States)

    Davidson, Brian P; Hodovan, James; Belcik, J Todd; Moccetti, Federico; Xie, Aris; Ammi, Azzdine Y; Lindner, Jonathan R

    2017-05-01

    Contrast-enhanced ultrasound (CEU) limb perfusion imaging is a promising approach for evaluating peripheral artery disease (PAD). However, low signal enhancement in skeletal muscle has necessitated high-power intermittent imaging algorithms, which are not clinically feasible. We hypothesized that CEU using a combination of intermediate power and a contrast agent resistant to inertial cavitation would allow real-time limb stress perfusion imaging. In normal volunteers, CEU of the calf skeletal muscle was performed on separate days with Sonazoid, Optison, or Definity. Progressive reduction in the ultrasound pulsing interval was used to assess the balance between signal enhancement and agent destruction at escalating mechanical indices (MI, 0.1-0.4). Real-time perfusion imaging at MI 0.1-0.4 using postdestructive replenishment kinetics was performed at rest and during 25 W plantar flexion contractile exercise. For Optison, limb perfusion imaging was unreliable at rest due to very low signal enhancement generated at all MIs and was possible during exercise-induced hyperemia only at MI 0.1 due to agent destruction at higher MIs. For Definity, signal intensity progressively increased with MI but was offset by microbubble destruction, which resulted in modest signal enhancement during CEU perfusion imaging and distortion of replenishment curves at MI ≥ 0.2. For Sonazoid, there strong signal enhancement at MI ≥ 0.2, with little destruction detected only at MI 0.4. Accordingly, high signal intensity and nondistorted perfusion imaging was possible at MI 0.2-0.3 and detected an 8.0- ± 5.7-fold flow reserve. Rest-stress limb perfusion imaging in humans with real-time CEU, which requires only seconds to perform, is possible using microbubbles with viscoelastic properties that produce strong nonlinear signal generation without destruction at intermediate acoustic pressures. Copyright © 2016 American Society of Echocardiography. All rights reserved.

  15. Synthesis of ultrasound contrast agents: characteristics and size distribution analysis (secondary publication)

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hak Jong [Program in Nano Science and Technology, Dept. of Transdisciplinary Studies, Seoul National University Graduate School of Convergence Science and Technology, Seoul (Korea, Republic of); Yoon, Tae Jong [Dept. of Radiology, Seoul National University Bundang Hospital, Seoul National University College of Medicine, Seongnam (Korea, Republic of); Yoon, Young Il [Dept. of Applied Bioscience, CHA University, Pocheon (Korea, Republic of)

    2017-10-15

    The purpose of this study was to establish a method for ultrasound (US) contrast agent synthesis and to evaluate the characteristics of the synthesized US contrast agent. A US contrast agent, composed of liposome and sulfur hexafluoride (SF6), was synthesized by dissolving 21 μmol 1,2-dihexadecanoyl-sn-glycero-3-phosphocholine (DPPC, C40H80NO8P), 9 μmol cholesterol, and 1.9 μmol of dihexadecylphosphate (DCP, [CH3(CH2)15O]2P(O)OH) in chloroform. After evaporation in a warm water bath and drying for 12-24 hours, the contrast agent was synthesized using the sonication process by the addition of a buffer and SF6 gas. The size distribution of the bubbles was analyzed using dynamic light scattering measurement methods. The degradation curve was evaluated by assessing the change in the number of contrast agent bubbles using light microscopy immediately, 12, 24, 36, 48, 60, 72, and 84 hours after synthesis. The echogenicity of the synthesized microbubbles was compared with commercially available microbubbles (SonoVue, Bracco). contrast agent was synthesized successfully using an evaporation-drying-sonication method. Most bubbles had a mean diameter of 154.2 nm and showed marked degradation 24 hours after synthesis. Although no statistically significant differences were observed between SonoVue and the synthesized contrast agent, a difference in echogenicity was observed between the synthesized contrast agent and saline (P<0.01). We successfully synthesized a US contrast agent using an evaporation-dryingsonication method. These results may help future research in the fields of anticancer drug delivery, gene delivery, targeted molecular imaging, and targeted therapy.

  16. Synthesis of ultrasound contrast agents: characteristics and size distribution analysis (secondary publication)

    International Nuclear Information System (INIS)

    Lee, Hak Jong; Yoon, Tae Jong; Yoon, Young Il

    2017-01-01

    The purpose of this study was to establish a method for ultrasound (US) contrast agent synthesis and to evaluate the characteristics of the synthesized US contrast agent. A US contrast agent, composed of liposome and sulfur hexafluoride (SF6), was synthesized by dissolving 21 μmol 1,2-dihexadecanoyl-sn-glycero-3-phosphocholine (DPPC, C40H80NO8P), 9 μmol cholesterol, and 1.9 μmol of dihexadecylphosphate (DCP, [CH3(CH2)15O]2P(O)OH) in chloroform. After evaporation in a warm water bath and drying for 12-24 hours, the contrast agent was synthesized using the sonication process by the addition of a buffer and SF6 gas. The size distribution of the bubbles was analyzed using dynamic light scattering measurement methods. The degradation curve was evaluated by assessing the change in the number of contrast agent bubbles using light microscopy immediately, 12, 24, 36, 48, 60, 72, and 84 hours after synthesis. The echogenicity of the synthesized microbubbles was compared with commercially available microbubbles (SonoVue, Bracco). contrast agent was synthesized successfully using an evaporation-drying-sonication method. Most bubbles had a mean diameter of 154.2 nm and showed marked degradation 24 hours after synthesis. Although no statistically significant differences were observed between SonoVue and the synthesized contrast agent, a difference in echogenicity was observed between the synthesized contrast agent and saline (P<0.01). We successfully synthesized a US contrast agent using an evaporation-dryingsonication method. These results may help future research in the fields of anticancer drug delivery, gene delivery, targeted molecular imaging, and targeted therapy

  17. Ultrasound triggered drug delivery with liposomal nested microbubbles.

    Science.gov (United States)

    Wallace, N; Wrenn, S P

    2015-12-01

    When ultrasound contrast agent microbubbles are nested within a liposome, damage to the liposome membrane caused by both stable and inertial cavitation of the microbubble allows for release of the aqueous core of the liposome. Triggered release was not accomplished unless microbubbles were present within the liposome. Leakage was tested using fluorescence assays developed specifically for this drug delivery vehicle and qualitative measurements using an optical microscope. These studies were done using a 1 MHz focused ultrasound transducer while varying parameters including peak negative ultrasound pressure, average liposome diameter, and microbubble concentration. Two regimes exist for membrane disruption caused by cavitating microbubbles. A faster release rate, as well as permanent membrane damage are seen for samples exposed to high pressure (2.1-3.7 MPa). A slower release rate and dilation/temporary poration are characteristic of stable cavitation for low pressure studies (0.54-1.7 MPa). Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Contrast-enhanced peripheral MRA. Technique and contrast agents

    International Nuclear Information System (INIS)

    Nielsen, Yousef W.; Thomsen, Henrik S.

    2012-01-01

    In the last decade contrast-enhanced magnetic resonance angiography (CE-MRA) has gained wide acceptance as a valuable tool in the diagnostic work-up of patients with peripheral arterial disease. This review presents current concepts in peripheral CE-MRA with emphasis on MRI technique and contrast agents. Peripheral CE-MRA is defined as an MR angiogram of the arteries from the aortic bifurcation to the feet. Advantages of CE-MRA include minimal invasiveness and lack of ionizing radiation. The basic technique employed for peripheral CE-MRA is the bolus-chase method. With this method a paramagnetic MRI contrast agent is injected intravenously and T1-weighted images are acquired in the subsequent arterial first-pass phase. In order to achieve high quality MR angiograms without interfering venous contamination or artifacts, a number of factors need to be taken into account. This includes magnetic field strength of the MRI system, receiver coil configuration, use of parallel imaging, contrast bolus timing technique, and k-space filling strategies. Furthermore, it is possible to optimize peripheral CE-MRA using venous compression techniques, hybrid scan protocols, time-resolved imaging, and steady-state MRA. Gadolinium(Gd)-based contrast agents are used for CE-MRA of the peripheral arteries. Extracellular Gd agents have a pharmacokinetic profile similar to iodinated contrast media. Accordingly, these agents are employed for first-pass MRA. Blood-pool Gd-based agents are characterized by prolonged intravascular stay, due to macromolecular structure or protein binding. These agents can be used for first-pass, as well as steady-state MRA. Some Gd-based contrast agents with low thermodynamic stability have been linked to development of nephrogenic systemic fibrosis in patients with severe renal insufficiency. Using optimized technique and a stable MRI contrast agent, peripheral CE-MRA is a safe procedure with diagnostic accuracy close to that of conventional catheter X

  19. The usefulness of US with contrast agent on breast tumors

    International Nuclear Information System (INIS)

    Jung, Hye An; Jung, Jung Im; Kim, Hak Hee; Son, Sang Bum; Byun, Jae Young; Lee, Jae Mun; Hahn, Sung Tae; Kim, Choon Yul

    2000-01-01

    To evaluate the usefulness of US with contrast agent breast tumors. Fifteen breast tumors in fourteen patients underwent color Doppler US before and after intravenous injection of a microbubble contrast agent (Levovist, Schering AG, Berlin, Germany). Benign lesions were 8 and malignant lesions were 7 among these. Real-time power Doppler ultrasonographic images were recorded on a videotape and representative images were color-printed. Tumor vascularity was analyzed on real-time images in regard to its presence or absence, and changes in diameter and number of vessels, presence or absence of blush around the vessels. Two observers reached a consensus. Results of malignant tumors were compared with those of benign tumors. Color Doppler signal intensity increased in 12 of 15 cases (80%). Number of vessel increased in 9 of 15 cases (60%) and diameter of vessel increased in 12 of 15 cases (80%). Vascular blush around the enhanced vessel was present in 5 of 15 patients (53%). Color Doppler signal increased in 5 of 8 benign lesions (63%) and 7 of 7 malignant lesions (100%). Number of vessel increased in 4 of 8 benign lesion (50%) and 5 of 7 malignant lesions (71%). Diameter of vessel increased in 5 of 8 benign lesions (63%) and 7 of 7 malignant lesions (100%). Blush around the enhanced vessel was present in one of 8 benign lesions (13%) and 4 of 7 malignant lesions (57%). The time to peak enhancement was shorter in malignant cases (mean=45 sec) than benign cases (mean=82 sec). US with contrast agent on breast tumors is effective to detect blood flow within the mass and may be helpful to differentiate malignant from benign lesions.

  20. Ambient pressure sensitivity of microbubbles investigated through a parameter study

    DEFF Research Database (Denmark)

    Andersen, Klaus Scheldrup; Jensen, Jørgen Arendt

    2009-01-01

    Measurements on microbubbles clearly indicate a relation between the ambient pressure and the acoustic behavior of the bubble. The purpose of this study was to optimize the sensitivity of ambient pressure measurements, using the subharmonic component, through microbubble response simulations....... The behavior of two microbubbles corresponding to two different contrast agents was investigated as a function of driving pulse and ambient overpressure, pov. Simulations of Levovist using a rectangular driving pulse show an almost linear reduction in the subharmonic component as pov is increased. For a 20...... found, although the reduction is not completely linear as a function of the ambient pressure....

  1. Acoustic Studies on Nanodroplets, Microbubbles and Liposomes

    Science.gov (United States)

    Kumar, Krishna Nandan

    Microbubbles and droplets are nanometer to micron size biocompatible particles which are primarily used for drug delivery and contrast imaging. Our aim is to broaden the use of microbubbles from contrast imaging to other applications such as measuring blood pressure. The other goal is to develop in situ contrast agents (phase shift droplets) which can be used for applications such as cancer tumor imaging. Therefore, the focus is on developing and validating the concept using experimental and theoretical methods. Below is an overview of each of the projects performed on droplets and microbubbles. Phase shift droplets vaporizable by acoustic stimulation offer many advantages over microbubbles as contrast agents due to their higher stability and possibility of smaller sizes. In this study, the acoustic droplet vaporization (ADV) threshold of a suspension of PFP droplets (400-3000nm) was acoustically measured as a function of the excitation frequency by examining the scattered signals, fundamental, sub- and second-harmonic. This work presents the experimental methodology to determine ADV threshold. The threshold increases with frequency: 1.25 MPa at 2.25 MHz, 2.0 MPa at 5 MHz and 2.5 MPa at 10 MHz. The scattered response from droplets was also found to match well with that of independently prepared lipid-coated microbubble suspension in magnitude as well as trends above the threshold value. Additionally, we have employed classical nucleation theory (CNT) to investigate the ADV, specifically the threshold value of the peak negative pressure required for vaporization. The theoretical analysis predicts that the ADV threshold increases with increasing surface tension of the droplet core and frequency of excitation, while it decreases with increasing temperature and droplet size. The predictions are in qualitative agreement with experimental observations. A technique to measure the ambient pressure using microbubbles was developed. Here we are presenting the results of an

  2. Contrast Agent in Magnetic Resonance Imaging

    DEFF Research Database (Denmark)

    Vu-Quang, Hieu

    2015-01-01

    Nanoparticles have been employed as contrast agent in magnetic resonance imaging (MRI) in order to improve sensitivity and accuracy in diagnosis. In addition, these contrast agents are potentially combined with other therapeutic compounds or near infrared bio-imaging (NIR) fluorophores to obtain...... theranostic or dual imaging purposes, respectively. There were two main types of MRI contrast agent that were synthesized during this PhD project including fluorine containing nanoparticles and magnetic nanoparticles. In regard of fluorine containing nanoparticles, there were two types contrast agent...... cancer cells for cancer diagnosis in MRI. F127-Folate coated SPION were stable in various types of suspension medium for over six months. They could specifically target folate receptor of cancer cells in vitro and in vivo thus enhancing the contrast in MRI T2/T2* weighted images. These are preliminary...

  3. Evaluation of chirp reversal power modulation sequence for contrast agent imaging

    International Nuclear Information System (INIS)

    Novell, A; Sennoga, CA; Escoffre, JM; Chaline, J; Bouakaz, A

    2014-01-01

    Over the last decade, significant research effort has been focused on the use of chirp for contrast agent imaging because chirps are known to significantly increase imaging contrast-to-noise ratio (CNR). New imaging schemes, such as chirp reversal (CR), have been developed to improve contrast detection by increasing non-linear microbubble responses. In this study we evaluated the contrast enhancement efficiency of various chirped imaging sequences in combination with well-established imaging schemes such as power modulation (PM) and pulse inversion (PI). The imaging schemes tested were implemented on a fully programmable open scanner and evaluated by ultrasonically scanning (excitation frequency of 2.5 MHz; amplitude of 350 kPa) a tissue-mimicking flow phantom comprising a 4 mm diameter tube through which aqueous dispersions (dilution fraction of 1/2000) of the commercial ultrasound contrast agent, SonoVue ® were continuously circulated. The recovery of non-linear microbubble responses after chirp compression requires the development and the optimization of a specific filter. A compression filter was therefore designed and used to compress and extract several non-linear components from the received microbubble responses. The results showed that using chirps increased the image CNR by approximately 10 dB, as compared to conventional Gaussian apodized sine burst excitation but degraded the axial resolution by a factor of 1.4, at −3 dB. We demonstrated that the highest CNR and contrast-to-noise ratio (CTR) were achievable when CR was combined with PM as compared to other imaging schemes such as PI. (paper)

  4. Contrast agent incompatibility with intravascular medications

    International Nuclear Information System (INIS)

    Irving, H.D.; Burbridge, B.E.

    1988-01-01

    In vitro and in vivo precipitation of iodinated contrast agents with commonly used medications have been reported. The intent of this in vitro study is to verify these reports and investigate other medications not previously tested. Contrast agents and medications were analyzed with a light spectrometer and observed for visible precipitates for up to 120 minutes. Previously reported incompatibilities were verified, and several new incompatibilities were discovered

  5. Counter-propagating wave interaction for contrast-enhanced ultrasound imaging

    Science.gov (United States)

    Renaud, G.; Bosch, J. G.; ten Kate, G. L.; Shamdasani, V.; Entrekin, R.; de Jong, N.; van der Steen, A. F. W.

    2012-11-01

    Most techniques for contrast-enhanced ultrasound imaging require linear propagation to detect nonlinear scattering of contrast agent microbubbles. Waveform distortion due to nonlinear propagation impairs their ability to distinguish microbubbles from tissue. As a result, tissue can be misclassified as microbubbles, and contrast agent concentration can be overestimated; therefore, these artifacts can significantly impair the quality of medical diagnoses. Contrary to biological tissue, lipid-coated gas microbubbles used as a contrast agent allow the interaction of two acoustic waves propagating in opposite directions (counter-propagation). Based on that principle, we describe a strategy to detect microbubbles that is free from nonlinear propagation artifacts. In vitro images were acquired with an ultrasound scanner in a phantom of tissue-mimicking material with a cavity containing a contrast agent. Unlike the default mode of the scanner using amplitude modulation to detect microbubbles, the pulse sequence exploiting counter-propagating wave interaction creates no pseudoenhancement behind the cavity in the contrast image.

  6. Contrasts agents in magnetic resonance imaging

    International Nuclear Information System (INIS)

    Bonnet, P.A.; Fernandez, J.P.; Milhavet, J.C.; Chapat, J.P.; Almes, C.; Bruel, J.M.; Rouanet, J.P.; Lamarque, J.L.

    1984-01-01

    Changing different parameters involved in imaging procedures, paramagnetic substances provide contrast enhancement in MRI. Contrast agents presently studied in animals and clinical trials, are either salts or complexes of mineral ions either nitroxide stable free radicals. Their development should extend the possibilities of tissular characterization and fonctional or metabolic evaluation of the MRI [fr

  7. Modeling of ultrasound propagation through contrast agents

    NARCIS (Netherlands)

    Grootens, J.J.F.A.H.; Mischi, M.; Böhmer, M.; Korsten, H.; Aarts, R.M.; Vander Sloten, Jos; Verdonck, Pascal; Nyssen, Marc

    2008-01-01

    In the past years many advances have been made in the detection of ultrasound contrast agents (UCA) by exploiting their nonlinear behavior. However, little attention has been paid to the nonlinear distortion of ultrasound (US) waves propagating through contrast media. The aim of this study is to

  8. [Preparation and preliminary evaluation of KGDS-targeted ultrasound contrast agent].

    Science.gov (United States)

    Gao, Feng; Ding, Yanfei; Sheng, Xiaoxi; Wang, Wei; Liang, Qi; Luo, Zhuoqiong; Zhou, Ping; Li, Hui

    2009-12-01

    To prepare a thrombus-targeted ultrasonic contrast agent and to investigate its targeted ability to fresh blood clots. We first synthesized FITC-KGDS-Palm compound, and then prepared thrombus-targeted microbubbles using "ultrasound & high speed shearing method". Fluorescence labeling thrombus-specific peptides and KGDS, directed at the activated glycoprotein(GP)IIb/IIIa receptor of platelets were attached to the surface of lipid microbubbles. The concentration and size of TUCA were measured by Malvern Zeta Sizer Nano-ZS590 and Coulter counter. Immunofluorescence was applied to confirm the conjugation. The conjunct ratio was assessed by flow cytometer (FCM). The KGDS-TUCA was straw yellow turbid liquor, and the concentration was 1.5 x 10(9)/mL, and the average size was 1.5 microm. The targeted microbubbles conjugated with the thrombus-specific peptides showed bright green rings by fluorescence microscope. FCM demonstrated that the wavelength of shell of KGDS-TUCA changed greatly, and the conjunct ratio was 90.04%. In vitro study showed KGDS-TUCA remained stable for 48 h at 4 degree C and target-attached to blood clots and showed good stability. The ultrasound & high speed shearing method to prepare TUCA is easy and in favor of purification. KGDS-TUCA has high specific biological activity. The conjunct ratio and stability of KGDS-TUCA are excellent.

  9. Contrast agent choice for intravenous coronary angiography

    International Nuclear Information System (INIS)

    Zeman, H.D.; Siddons, D.P.

    1989-01-01

    The screening of the general population for coronary artery disease would be practical if a method existed for visualizing the extent of occlusion after an intravenous injection of contrast agent. Measurements performed with monochromatic synchrotron radiation x-rays and an iodine containing contrast agent at the Stanford Synchrotron Radiation Laboratory have shown that such an intravenous angiography procedure would be possible with an adequately intense monochromatic x-ray source. Because of the size and cost of synchrotron radiation facilities it would be desirable to make the most efficient use of the intensity available, while reducing as much as possible the radiation dose experienced by the patient. By choosing contrast agents containing elements with a higher atomic number than iodine, it is possible to both improve the image quality and reduce the patient radiation dose, while using the same synchrotron source. By using Si monochromator crystals with a small mosaic spread, it is possible to increase the x-ray flux available for imaging by over an order of magnitude, without any changes in the storage ring or wiggler magnet. The most critical imaging task for intravenous coronary angiography utilizing synchrotron radiation x-rays is visualizing a coronary artery through the left ventricle or aorta which also contains a contrast agent. Calculations have been made of the signal to noise ratio expected for this imaging task for various contrast agents with atomic numbers between that of iodine and bismuth

  10. Use of contrast agents for liver MRI

    International Nuclear Information System (INIS)

    Ward, Janice

    2007-01-01

    Contrast-enhanced MRI is recognised as one of the most accurate imaging methods for investigating diseases of the liver. Uniquely several different types of contrast agents are available for liver MRI. They can be divided into non-specific extracellular fluid space (ECF), hepatocyte specific and reticulo-endothelial system (RES) specific agents. They are used to improve the detection of focal liver lesions by increasing normal-abnormal tissue contrast and to assist in lesion characterisation by demonstrating tissue perfusion and cellular function. ECF-gadolinium (Gd) chelates have been widely used in abdominal MRI for many years. They provide valuable information regarding the vascularisation and perfusion characteristics of lesions and assist in lesion detection, particularly of hypervascular lesions. The hepatocyte and RES-specific agents further improve lesion detection, provide important functional information and allow the distinction between hepatocellular and non-hepatocellular tumours. This article describes the different MR contrast agents and discusses their current status for diagnosing focal liver lesions. The importance of optimised technique and appropriate selection of contrast agent is emphasised

  11. Process for preparation of MR contrast agents

    DEFF Research Database (Denmark)

    2002-01-01

    The present invention provides a process for the preparation of an MR contrast agent, said process comprising: i) obtaining a solution in a solvent of a hydrogenatable, unsaturated substrate compound and a catalyst for the hydrogenation of said substrate compound; ii) introducing said solution...... in droplet form into a chamber containing hydrogen gas (H2) enriched in para-hydrogen (p-1H2) and/or ortho-deuterium (o-2H2) whereby to hydrogenate said substrate to form a hydrogenated imaging agent; iii) optionally subjecting said hydrogenated imaging agent to a magnetic field having a field strength below...... earth's ambient field strength; iv) optionally dissolving said imaging agent in an aqueous medium; v) optionally separating said catalyst from the solution of said imaging agent in said aqueous medium; vi) optionally separating said solvent from the solution of said imaging agent in said aqueous medium...

  12. Dynamic microbubble contrast-enhanced US to measure tumor response to targeted therapy: a proposed clinical protocol with results from renal cell carcinoma patients receiving antiangiogenic therapy.

    Science.gov (United States)

    Williams, Ross; Hudson, John M; Lloyd, Brendan A; Sureshkumar, Ahthavan R; Lueck, Gordon; Milot, Laurent; Atri, Mostafa; Bjarnason, Georg A; Burns, Peter N

    2011-08-01

    To develop and implement an evidence-based protocol for characterizing vascular response of renal cell carcinoma (RCC) to targeted therapy by using dynamic contrast material-enhanced (DCE) ultrasonography (US). The study was approved by the institutional research ethics board; written informed consent was obtained from all patients. Seventeen patients (four women; median age, 58 years; range, 42-72 years; 13 men, median age, 62 years; range, 45-81 years) with metastatic RCC were examined by using DCE US before and after 2 weeks of treatment with sunitinib (May 2007 to October 2009). Two contrast agent techniques--bolus injection and disruption-replenishment infusion of microbubbles--were compared. Changes in tumor blood velocity and fractional blood volume were measured with both methods, together with reproducibility and effect of compensation for respiratory motion. Tumor changes were assessed with computed tomography, by using the best response with the Response Evaluation Criteria in Solid Tumors (RECIST) and progression-free survival (PFS). Follow-up RECIST measurements were performed at 6-week intervals until progressive disease was detected. In response to treatment, median tumor fractional blood volume measured with the disruption-replenishment infusion method decreased by 73.2% (interquartile range, 46%-87%) (P protocol is a flexible method suitable for many tumor types, but further studies are needed to assess whether this protocol may be predictive of patient outcome. © RSNA, 2011.

  13. Polymeric nanoparticles as OCT contrast agents

    Energy Technology Data Exchange (ETDEWEB)

    Al Rawashdeh, Wa' el [RWTH Aachen University, Experimental Molecular Imaging (Germany); Kray, Stefan [RWTH Aachen University, Institute for Semiconductor Electronics (Germany); Pich, Andrij; Pargen, Sascha; Balaceanu, Andreea [RWTH Aachen University, Interactive Material Research (DWI) (Germany); Lenz, Markus; Spoeler, Felix [RWTH Aachen University, Institute for Semiconductor Electronics (Germany); Kiessling, Fabian, E-mail: fkiessling@ukaachen.de; Lederle, Wiltrud [RWTH Aachen University, Experimental Molecular Imaging (Germany)

    2012-12-15

    In this study, the optical properties of two nano-sized polymer colloids in optical coherence tomography (OCT) were compared in vitro with respect to their potential use as contrast agents. We used two types of particles: compact hydrophobic spherical polystyrene (PS) particles and soft water-swollen nanogel (NG) particles both with grafted hydrophilic shell, both prepared at two different sizes (PS at 300 and 150 nm, NG at 300 and 200 nm). The OCT backscattering signals of the particles in a vessel-mimicking highly scattering agar/TiO{sub 2} phantom were compared on either number of particles or weight percent. Larger particles and higher concentrations produced higher OCT contrast. At each concentration tested, a markedly higher contrast was achieved by PS particles than NG particles. PS particles generated a markedly higher OCT contrast than the phantom at concentrations of at least 1 Multiplication-Sign 10{sup 10} or 0.1 % for PS 300 nm and at least 3 Multiplication-Sign 10{sup 11} particles/mL or 0.4 % for PS 150 nm. The contrast generated by NG 300 nm was above the phantom contrast at concentrations of at least 3 Multiplication-Sign 10{sup 11} particles/mL or 1 %, whereas NG 200 nm only at 4 %. At any given weight percent, the differences in OCT contrast between differently sized particles were much less evident than in the comparison based on particle number. PS 300 nm generated also a good contrast ex vivo on chicken muscle tissue. These results strongly suggest that PS spheres have strong potential as intravascular OCT contrast agent, while NG particles need further contrast enhancer for being used as OCT contrast agent.

  14. Non-radiological contrast agents (MRI)

    International Nuclear Information System (INIS)

    Bonnemain, B.; Lautrou, J.; Meyer, D.; Doucet, D.

    1987-01-01

    Over the past few years, extensive research has been carried out in an attempt to develop contrast agents that could help improve both the performance (acquisition times) and the diagnostic efficacy of Magnetic Resonance Imaging (MRI) techniques. On the basis of physicochemical and pharmacological criteria discussed in this presentation, a few efficacious, well-tolerated compounds could be developed. Two of them, the gadolinium complexes Gd-DOTA and Gd-DTPA, are currently being tried in man. This first generation of contrast agents, which are aspecific markers of the intravascular space, has been shown to have good diagnostic potential in conventional MRI procedures. The diagnostic contribution of these contrast agents will probably be a most essential factor in new MRI techniques using low field strengh or fast imaging sequences [fr

  15. Contrast agent choice for intravenous coronary angiography

    International Nuclear Information System (INIS)

    Zeman, H.D.; Siddons, D.P.

    1990-01-01

    The screening of the general population for coronary artery disease would be practical if a method existed for visualizing the extent of occlusion after an intravenous injection of contrast agent. Measurements performed with monochromatic synchrotron radiation X-rays and an iodine-containing contrast agent at the Stanford Synchrotron Radiation Laboratory have shown that such an intravenous angiography procedure would be possible with an adequately intense monochromatic X-ray source. Because of the size and cost of synchrotron radiation facilities it would be desirable to make the most efficient use of the intensity available, while reducing as much as possible the radiation dose experienced by the patient. By choosing contrast agents containing elements with a higher atomic number than iodine, it is possible to both improve the image quality and reduce the patient radiation dose, while using the same synchrotron radiation source. By using Si monochromator crystals with a small mosaic spread, it is possible to increase the X-ray flux available for imaging by over an order of magnitude, without any changes in the storage ring or wiggler magnet. The most critical imaging task for intravenous coronary angiography utilizing synchrotron radiation X-rays is visualizing a coronary artery through the left ventricle or aorta which also contain contrast agent. Calculations have been made of the signal to noise ratio expected for this imaging task for various contrast agents with atomic numbers between that of iodine and bismuth. The X-ray energy spectrum of the X-17 superconduction wiggler beam line at the National Synchrotron Light Source at Brookhaven National Laboratory has been used for these calculations. Both perfect Si crystals and Si crystals with a small mosaic spread are considered as monochromators. Contrast agents containing Gd or Yb seem to have about the optimal calculated signal to noise ratio. (orig./HSI)

  16. Interactions of ionic and nonionic contrast agents with thrombolytic agents

    International Nuclear Information System (INIS)

    Fareed, J.; Moncada, R.; Scanlon, P.; Hoppensteadt, D.; Huan, X.; Walenga, J.M.

    1987-01-01

    Both the ionic and nonionic intravascular contrast media have been used before and after the administration of thrombolytic agents to evaluate clot lysis during angioplasty and the treatment of myocardial infarction. In experimental animal models, the authors found that the clot lytic efficacy of streptokinase, streptokinase-plasminogen complex, and tissue plasminogen activator (t-PA) is markedly augmented if these agents are administered within 1 hour after the angiographic producers. Furthermore, contrast agents injected after the administration of t-Pa exhibit a synergistic action. In stimulated models administration of one ionic contrast medium (Angiovist, Berlex, Wayne, NJ) and two nonionic contrast agents (Isovue-370, Squibb Diagnostics, New Brunswick, NJ; Omnipaque-350, Winthrop, NY) 15 minutes before the administration of t-PA resulted in marked enhancement of the lytic activity. Although the mechanism of this interaction is unknown at this time, it should be taken into consideration in the treatment of patients with myocardial infarction, in whom contrast agents are continually used to evaluate the therapeutic lysis. Furthermore, this interaction may be partly related to the therapeutic efficacy and/or hemorrhagic actions observed

  17. Acoustic Characterization and Enhanced Ultrasound Imaging of Long-Circulating Lipid-Coated Microbubbles.

    Science.gov (United States)

    Li, Hongbo; Yang, Yanye; Zhang, Meimei; Yin, Liping; Tu, Juan; Guo, Xiasheng; Zhang, Dong

    2018-05-01

    A long-circulating lipid-coated ultrasound (US) contrast agent was fabricated to achieve a longer wash-out time and gain more resistance against higher-mechanical index sonication. Systemic physical, acoustic, and in vivo imaging experiments were performed to better understand the underlying mechanism enabling the improvement of contrast agent performance by adjusting the physical and acoustic properties of contrast agent microbubbles. By simply altering the gas core, a kind of US contrast agent microbubble was synthesized with a similar lipid-coating shell as SonoVue microbubbles (Bracco SpA, Milan, Italy) to achieve a longer wash-out time and higher inertial cavitation threshold. To bridge the structure-performance relationship of the synthesized microbubbles, the imaging performance of the microbubbles was assessed in vivo with SonoVue as a control group. The size distribution and inertial cavitation threshold of the synthesized microbubbles were characterized, and the shell parameters of the microbubbles were determined by acoustic attenuation measurements. All of the measurements were compared with SonoVue microbubbles. The synthesized microbubbles had a spherical shape, a smooth, consistent membrane, and a uniform distribution, with an average diameter of 1.484 μm. According to the measured attenuation curve, the synthesized microbubbles resonated at around 2.8 MHz. Although the bubble's shell elasticity (0.2 ± 0.09 N/m) was comparable with SonoVue, it had relatively greater viscosity and inertial cavitation because of the different gas core. Imaging studies showed that the synthesized microbubbles had a longer circulation time and a better chance of fighting against rapid collapse than SonoVue. Nano/micrometer long-circulating lipid-coated microbubbles could be fabricated by simply altering the core composition of SonoVue microbubbles with a higher-molecular weight gas. The smaller diameter and higher inertial cavitation threshold of the

  18. CEST and PARACEST MR contrast agents

    International Nuclear Information System (INIS)

    Hancu, Ileana; Dixon, W. Thomas; Woods, Mark; Sherry, A. Dean; Vinogradov, Elena; Lenkinski, Robert E.

    2010-01-01

    In this review we describe the status of development for a new class of magnetic resonance (MR) contrast agents, based on chemical exchange saturation transfer (CEST). The mathematics and physics relevant to the description of the CEST effect in MR are presented in an appendix published in the online version only. We discuss the issues arising when translating in vitro results obtained with CEST agents to using these MR agents in in vivo model studies and in humans. Examples are given on how these agents are imaged in vivo. We summarize the status of development of these CEST agents, and speculate about the next steps that may be taken towards the demonstration of CEST MR imaging in clinical applications

  19. Contrast-enhanced ultrasound imaging and in vivo circulatory kinetics with low-boiling-point nanoscale phase-change perfluorocarbon agents.

    Science.gov (United States)

    Sheeran, Paul S; Rojas, Juan D; Puett, Connor; Hjelmquist, Jordan; Arena, Christopher B; Dayton, Paul A

    2015-03-01

    Many studies have explored phase-change contrast agents (PCCAs) that can be vaporized by an ultrasonic pulse to form microbubbles for ultrasound imaging and therapy. However, few investigations have been published on the utility and characteristics of PCCAs as contrast agents in vivo. In this study, we examine the properties of low-boiling-point nanoscale PCCAs evaluated in vivo and compare data with those for conventional microbubbles with respect to contrast generation and circulation properties. To do this, we develop a custom pulse sequence to vaporize and image PCCAs using the Verasonics research platform and a clinical array transducer. Results indicate that droplets can produce contrast enhancement similar to that of microbubbles (7.29 to 18.24 dB over baseline, depending on formulation) and can be designed to circulate for as much as 3.3 times longer than microbubbles. This study also reports for the first time the ability to capture contrast washout kinetics of the target organ as a measure of vascular perfusion. Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  20. Cardiac image segmentation for contrast agent videodensitometry

    NARCIS (Netherlands)

    Mischi, M.; Kalker, A.A.C.M.; Korsten, H.H.M.

    2005-01-01

    Indicator dilution techniques are widely used in the intensive care unit and operating room for cardiac parameter measurements. However, the invasiveness of current techniques represents a limitation for their clinical use. The development of stable ultrasound contrast agents allows new applications

  1. Contrast agents in magnetic resonance imaging

    International Nuclear Information System (INIS)

    Karadjian, V.

    1987-01-01

    The origine of nuclear magnetic resonance signal is reminded and different ways for contrast enhancement in magnetic resonance imaging are presented, especially, modifications of tissus relaxation times. Investigations have focused on development of agents incorporating either paramagnetic ions or stable free radicals. Pharmacological and toxicological aspects are developed. The diagnostic potential of these substances is illustrated by the example of gadolinium complexes [fr

  2. Advanced detection strategies for ultrasound contrast agents

    NARCIS (Netherlands)

    J.M.G. Borsboom (Jerome)

    2005-01-01

    markdownabstract__Abstract__ Ultrasound contrast agent was discovered serendipitously by Gramiak and Shah in I968 when they injected indocyanine green dye into the heart and observed increased echogenicity of the blood containing the dye. Small cavitation bubbles that were formed upon

  3. Theragnostic ultrasound using microbubbles in the treatment of prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hak Jong; Yoon, Young Il; Bae, Yun Jung [Dept. of Radiology, Seoul National University Bundang Hospital, Seongnam (Korea, Republic of)

    2016-08-15

    The use of gas-filled microbubbles in perfusion monitoring as intravascular ultrasound contrast agents has recently become more common. Additionally, microbubbles are employed as carriers of pharmaceutical substances or genes. Microbubbles have great potential to improve the delivery of therapeutic materials into cells and to modify vascular permeability, causing increased extravasation of drugs and drug carriers. Prostate cancer is the most common neoplasm in Europe and America, with an incidence twice to three times that of lung and colorectal cancer. Its incidence is still rising in Asian countries, including Japan and Korea. In this review, we present current strategies regarding the synthesis of microbubbles with targeted ligands on their surfaces, with a focus on prostate cancer.

  4. Balancing stealth and echogenic properties in an ultrasound contrast agent with drug delivery potential.

    Science.gov (United States)

    Jablonowski, Lauren J; Alfego, David; Andorko, James I; Eisenbrey, John R; Teraphongphom, Nutte; Wheatley, Margaret A

    2016-10-01

    Contrast agents are currently being modified to combine diagnostic and therapeutic capabilities. For ultrasound (US) imaging with polymeric contrast agents, it is necessary to modify the shell to create "stealth" microbubbles but without these modifications sacrificing the agent's ability to interact with the focused US beam. We hypothesize that addition of the classic immune shielding molecule polyethylene glycol (PEG) to a polylactide (PLA) microbubble shell will affect the acoustic and physical properties of the resulting agents. In an effort to determine the best formulation to achieve a balance between stealth and acoustic activity, we compared two PEGylation techniques; addition of increasing amounts of PEG-PLA copolymer and employing incorporation of a PEG lipid (LipidPEG) into the shell. Loss of acoustic enhancement occurred in a dose-dependent manner for both types of PEGylated agents (loss of signal occurred at >5 wt% PEG-PLA and >1 wt% LipidPEG), while immune activation was also reduced in a dose-dependent manner for the PEG-PLA agents. This study shows that the balance between acoustic behavior and improved immune avoidance was scalable and successful to different degrees with both PEGylation methods, and was best achieved using for PEG-PLA at 5 wt% and for LipidPEG at 1 wt%. Studies are ongoing to evaluate the best method for the targeting and drug delivery capabilities of these agents for applications in cancer treatment. This study represents the basis for understanding the consequences of making modifications to the native polymeric shell. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Influence of contrast agent dose and ultrasound exposure on cardiomyocyte injury induced by myocardial contrast echocardiography in rats.

    Science.gov (United States)

    Miller, Douglas L; Li, Peng; Dou, Chunyan; Gordon, David; Edwards, Chris A; Armstrong, William F

    2005-10-01

    To detect specific cardiomyocyte injury induced by myocardial contrast material-enhanced echocardiography (ie, myocardial contrast echocardiography) in rats and to ascertain the influences of contrast material dose and ultrasound exposure on this injury. All animal procedures were approved by the university committee for the use and care of animals. Myocardial contrast echocardiography with 1:4 electrocardiographic (ECG) triggering was performed at 1.5 MHz in 61 anesthetized rats. Evans blue (EB) dye was injected as the vital stain for cardiomyocyte injury. At the start of myocardial contrast echocardiography, which lasted 10 minutes, perflutren lipid microsphere-based contrast material was infused through the tail vein for 5 minutes. Premature heartbeats were counted from the ECG record. The numbers of EB-stained cells counted on sections of heart specimens obtained 24 hours after myocardial contrast echocardiography and then either fresh frozen or embedded in paraffin were determined by using fluorescence microscopy. Results were compared statistically by using t tests and Mann-Whitney rank sum tests. EB-stained cells were concentrated in the anterior region of the myocardium. In the paraffin-embedded specimens, EB-stained cells were often accompanied by but largely separate from areas of inflammatory cell infiltration. At end-systolic triggering with a 50 microL/kg dose of microsphere contrast material, the EB-stained cell count increased with increasing peak rarefactional pressure amplitude, with significantly increased cell counts at 1.6 MPa (P .1). EB-stained cell counts increased with increasing contrast material dose, from 10 to 50 microL/kg, at 2.0 MPa. Cardiomyocyte injury was induced by the interaction of ultrasound pulses with contrast agent microbubbles during myocardial contrast echocardiography in rats, and the numbers of injured cells increased with increasing contrast agent dose and ultrasound exposure. RSNA, 2005

  6. Inertial cavitation threshold of nested microbubbles.

    Science.gov (United States)

    Wallace, N; Dicker, S; Lewin, Peter; Wrenn, S P

    2015-04-01

    Cavitation of ultrasound contrast agents (UCAs) promotes both beneficial and detrimental bioeffects in vivo (Radhakrishnan et al., 2013) [1]. The ability to determine the inertial cavitation threshold of UCA microbubbles has potential application in contrast imaging, development of therapeutic agents, and evaluation of localized effects on the body (Ammi et al., 2006) [2]. This study evaluates a novel UCA and its inertial cavitation behavior as determined by a home built cavitation detection system. Two 2.25 MHz transducers are placed at a 90° angle to one another where one transducer is driven by a high voltage pulser and the other transducer receives the signal from the oscillating microbubble. The sample chamber is placed in the overlap of the focal region of the two transducers where the microbubbles are exposed to a pulser signal consisting of 600 pulse trains per experiment at a pulse repetition frequency of 5 Hz where each train has four pulses of four cycles. The formulation being analyzed is comprised of an SF6 microbubble coated by a DSPC PEG-3000 monolayer nested within a poly-lactic acid (PLA) spherical shell. The effect of varying shell diameters and microbubble concentration on cavitation threshold profile for peak negative pressures ranging from 50 kPa to 2 MPa are presented and discussed in this paper. The nesting shell decreases inertial cavitation events from 97.96% for an un-nested microbubble to 19.09% for the same microbubbles nested within a 2.53 μm shell. As shell diameter decreases, the percentage of inertially cavitating microbubbles also decreases. For nesting formulations with average outer capsule diameters of 20.52, 14.95, 9.95, 5.55, 2.53, and 1.95 μm, the percentage of sample destroyed at 1 MPa was 51.02, 38.94, 33.25, 25.27, 19.09, and 5.37% respectively. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. Magnetic resonance properties of Gd(III)-bound lipid-coated microbubbles and their cavitation fragments.

    Science.gov (United States)

    Feshitan, Jameel A; Boss, Michael A; Borden, Mark A

    2012-10-30

    Gas-filled microbubbles are potentially useful theranostic agents for magnetic resonance imaging-guided focused ultrasound surgery (MRIgFUS). Previously, MRI at 9.4 T was used to measure the contrast properties of lipid-coated microbubbles with gadolinium (Gd(III)) bound to lipid headgroups, which revealed that the longitudinal molar relaxivity (r(1)) increased after microbubble fragmentation. This behavior was attributed to an increase in water proton exchange with the Gd(III)-bound lipid fragments caused by an increase in the lipid headgroup area that accompanied the lipid shell monolayer-to-bilayer transition. In this article, we explore this mechanism by comparing the changes in r(1) and its transverse counterpart, r(2)*, after the fragmentation of microbubbles consisting of Gd(III) bound to two different locations on the lipid monolayer shell: the phosphatidylethanolamine (PE) lipid headgroup region or the distal region of the poly(ethylene glycol) (PEG) brush. Nuclear magnetic resonance (NMR) at 1.5 T was used to measure the contrast properties of the various microbubble constructs because this is the most common field strength used in clinical MRI. Results for the lipid-headgroup-labeled Gd(III) microbubbles revealed that r(1) increased after microbubble fragmentation, whereas r(2)* was unchanged. An analysis of PEG-labeled Gd(III) microbubbles revealed that both r(1) and r(2)* decreased after microbubble fragmentation. Further analysis revealed that the microbubble gas core enhanced the transverse MR signal (T(2)*) in a concentration-dependent manner but minimally affected the longitudinal (T(1)) signal. These results illustrate a new method for the use of NMR to measure the biomembrane packing structure and suggest that two mechanisms, proton-exchange enhancement by lipid membrane relaxation and magnetic field inhomogeneity imposed by the gas/liquid interface, may be used to detect and differentiate Gd(III)-labeled microbubbles and their cavitation

  8. Fabrication and application of a magnetic-targeting and controlled-release system using ST68-based microbubbles

    International Nuclear Information System (INIS)

    Xing Zhanwen; Ke Hengte; Wang Jinrui; Zhao Bo; Qu Enze; Yue Xiuli; Dai Zhifei

    2013-01-01

    Objective: To manufacture magnetic microbubbles with dual-response to ultrasound and magnetic fields. Methods: Microbubbles of ultrasound contrast agent (ST68) based on a surfactant were prepared by the acoustic cavitation method. Fe 3 O 4 magnetic nanoparticles with negative charge were synthesized using the polyol procedure. Magnetic microbubbles were generated by depositing polyethylenimine and Fe 3 O 4 magnetic nanoparticles alternately onto the microbubbles using the layer-by-layer self-assembly. In vitro ultrasonography was performed on a silicone tube with/without magnetic microbubbles (3 × 10 8 /ml) by a self-made device to observe the movement of magnetic microbubbles under the effects of magnetic field. In vivo imaging was performed on the kidney of New Zealand rabbits before and after the injection of magnetic microbubbles. Results: The Fe 3 O 4 nanoparticles carried a stable negative charge of (-24.6 ± 6.7) mV and more than 98% of the particles were less than 8 μm in diameter, meeting the size requirement of an ultrasound contrast agent for intravenous administration. There was no echoic signal in the silicone tube before injection of magnetic microbubbles, but there were strong echoic signals after injection. After applying a magnetic field, the magnetic microbubbles moved along the direction of the magnetic flux. In vivo ultrasound imaging could not visualize the kidney before injection of magnetic microbubbles, but could remarkably visualize the kidney after injection. Conclusions: The magnetic microbubbles exhibit favorable magnetic targeting and ultrasound contrast enhancement characteristics. Such properties may serve as the foundation to study their potential for simultaneous diagnosis and treatment in the future. (authors)

  9. Microbubble Composition and Preparation for High-Frequency Contrast-Enhanced Ultrasound Imaging : In Vitro and in Vivo Evaluation

    NARCIS (Netherlands)

    Daeichin, Verya; van Rooij, Tom; Skachkov, Ilya; Ergin, Bulent; Specht, Patricia A.C.; Lima, Alexandre; Ince, Can; Bosch, Johan G.; van der Steen, A.F.W.; de Jong, N.; Kooiman, Klazina

    2017-01-01

    Although high-frequency ultrasound imaging is gaining attention in various applications, hardly any ultrasound contrast agents (UCAs) dedicated to such frequencies (>15 MHz) are available for contrast-enhanced ultrasound (CEUS) imaging. Moreover, the composition of the limited commercially

  10. Microbubble Composition and Preparation for High-Frequency Contrast-Enhanced Ultrasound Imaging: In Vitro and In Vivo Evaluation

    NARCIS (Netherlands)

    Daeichin, Verya; van Rooij, Tom; Skachkov, Ilya; Ergin, Bulent; Specht, Patricia A. C.; Lima, Alexandre; Ince, Can; Bosch, Johan G.; van der Steen, Antonius F. W.; de Jong, Nico; Kooiman, Klazina

    2017-01-01

    Although high-frequency ultrasound imaging is gaining attention in various applications, hardly any ultrasound contrast agents (UCAs) dedicated to such frequencies (>15 MHz) are available for contrast-enhanced ultrasound (CEUS) imaging. Moreover, the composition of the limited commercially available

  11. Microbubble Composition and Preparation for High-Frequency Contrast-Enhanced Ultrasound Imaging: In Vitro and in Vivo Evaluation

    NARCIS (Netherlands)

    V. Daeichin (Verya); T. van Rooij (Tom); I. Skachkov (Ilya); B. Ergin (Bulent); P. Specht (Patricia); A.A.P. Lima (Alexandre ); C. Ince (Can); J.G. Bosch (Hans); A.F.W. van der Steen (Ton); N. de Jong (Nico); K. Kooiman (Klazina)

    2017-01-01

    textabstractAlthough high-frequency ultrasound imaging is gaining attention in various applications, hardly any ultrasound contrast agents (UCAs) dedicated to such frequencies (>15 MHz) are available for contrast-enhanced ultrasound (CEUS) imaging. Moreover, the composition of the limited

  12. Imaging of vaporised sub-micron phase change contrast agents with high frame rate ultrasound and optics

    Science.gov (United States)

    Lin, Shengtao; Zhang, Ge; Jamburidze, Akaki; Chee, Melisse; Hau Leow, Chee; Garbin, Valeria; Tang, Meng-Xing

    2018-03-01

    Phase-change ultrasound contrast agent (PCCA), or nanodroplet, shows promise as an alternative to the conventional microbubble agent over a wide range of diagnostic applications. Meanwhile, high-frame-rate (HFR) ultrasound imaging with microbubbles enables unprecedented temporal resolution compared to traditional contrast-enhanced ultrasound imaging. The combination of HFR ultrasound imaging and PCCAs can offer the opportunity to observe and better understand PCCA behaviour after vaporisation captures the fast phenomenon at a high temporal resolution. In this study, we utilised HFR ultrasound at frame rates in the kilohertz range (5-20 kHz) to image native and size-selected PCCA populations immediately after vaporisation in vitro within clinical acoustic parameters. The size-selected PCCAs through filtration are shown to preserve a sub-micron-sized (mean diameter  1 µm) that originate from native PCCA emulsion. The results demonstrate imaging signals with different amplitudes and temporal features compared to that of microbubbles. Compared with the microbubbles, both the B-mode and pulse-inversion (PI) signals from the vaporised PCCA populations were reduced significantly in the first tens of milliseconds, while only the B-mode signals from the PCCAs were recovered during the next 400 ms, suggesting significant changes to the size distribution of the PCCAs after vaporisation. It is also shown that such recovery in signal over time is not evident when using size-selective PCCAs. Furthermore, it was found that signals from the vaporised PCCA populations are affected by the amplitude and frame rate of the HFR ultrasound imaging. Using high-speed optical camera observation (30 kHz), we observed a change in particle size in the vaporised PCCA populations exposed to the HFR ultrasound imaging pulses. These findings can further the understanding of PCCA behaviour under HFR ultrasound imaging.

  13. Bioeffects of albumin-encapsulated microbubbles and real-time myocardial contrast echocardiography in an experimental canine model

    Directory of Open Access Journals (Sweden)

    P.M.M. Dourado

    2006-06-01

    Full Text Available Myocardial contrast echocardiography has been used for assessing myocardial perfusion. Some concerns regarding its safety still remain, mainly regarding the induction of microvascular alterations. We sought to determine the bioeffects of microbubbles and real-time myocardial contrast echocardiography (RTMCE in a closed-chest canine model. Eighteen mongrel dogs were randomly assigned to two groups. Nine were submitted to continuous intravenous infusion of perfluorocarbon-exposed sonicated dextrose albumin (PESDA plus continuous imaging using power pulse inversion RTMCE for 180 min, associated with manually deflagrated high-mechanical index impulses. The control group consisted of 3 dogs submitted to continuous imaging using RTMCE without PESDA, 3 dogs received PESDA alone, and 3 dogs were sham-operated. Hemodynamics and cardiac rhythm were monitored continuously. Histological analysis was performed on cardiac and pulmonary tissues. No hemodynamic changes or cardiac arrhythmias were observed in any group. Normal left ventricular ejection fraction and myocardial perfusion were maintained throughout the protocol. Frequency of mild and focal microhemorrhage areas in myocardial and pulmonary tissue was similar in PESDA plus RTMCE and control groups. The percentages of positive microscopical fields in the myocardium were 0.4 and 0.7% (P = NS in the PESDA plus RTMCE and control groups, respectively, and in the lungs they were 2.1 and 1.1%, respectively (P = NS. In this canine model, myocardial perfusion imaging obtained with PESDA and RTMCE was safe, with no alteration in cardiac rhythm or left ventricular function. Mild and focal myocardial and pulmonary microhemorrhages were observed in both groups, and may be attributed to surgical tissue manipulation.

  14. Smart Contrast Agents for Magnetic Resonance Imaging.

    Science.gov (United States)

    Bonnet, Célia S; Tóth, Éva

    2016-01-01

    By visualizing bioactive molecules or biological parameters in vivo, molecular imaging is searching for information at the molecular level in living organisms. In addition to contributing to earlier and more personalized diagnosis in medicine, it also helps understand and rationalize the molecular factors underlying physiological and pathological processes. In magnetic resonance imaging (MRI), complexes of paramagnetic metal ions, mostly lanthanides, are commonly used to enhance the intrinsic image contrast. They rely either on the relaxation effect of these metal chelates (T(1) agents), or on the phenomenon of paramagnetic chemical exchange saturation transfer (PARACEST agents). In both cases, responsive molecular magnetic resonance imaging probes can be designed to report on various biomarkers of biological interest. In this context, we review recent work in the literature and from our group on responsive T(1) and PARACEST MRI agents for the detection of biogenic metal ions (such as calcium or zinc), enzymatic activities, or neurotransmitter release. These examples illustrate the general strategies that can be applied to create molecular imaging agents with an MRI detectable response to biologically relevant parameters.

  15. Novel contrast agent for liver and spleen

    International Nuclear Information System (INIS)

    Seltzer, S.E.; Blau, M.; Adams, D.F.; Janoff, A.; Minchey, S.

    1991-01-01

    This paper determines whether the biodistribution and imaging characteristics of a liposome-encapsulated contrast agent, iotrolan-carrying interdigitation fusion (IF) vesicles, were acceptable for a liver-spleen CT contrast agent. IF vesicles with iotrolan in their aqueous phase were prepared by fusing small unilamellar liposomes into larger vesicles. The iodine-to-lipid ratio was 4.7. Biodistribution was measured with I-125 iotrolan-labeled IF vesicles in rats. CT imaging (Somatom Plus, Siemens Medical Systems) was performed in dogs. At the lowest dose (10 mg of iodine and 2.1 mg of lipid per kilogram) 72% of the ID was in the liver, 5% in spleen, and 1% in lungs at 1 hour. At the highest dose, (1,000 mg of iodine and 212 mg of lipid per kilogram), liver values were 68% ID, while spleen rose to 18%, lung 5%. Liver and spleen values stayed at peak for 24 hours then fell; the half-life was 6 days. In dogs, liver and spleen enhancement at 1 hour averaged 652 and 256 HU above baseline per gram of iodine per kilogram, respectively

  16. Development of organic MRI contrast agents

    International Nuclear Information System (INIS)

    Hayashi, Hiroyuki; Sato, Yuichiro; Karasawa, Satoru; Koga, Noboru

    2008-01-01

    Described are trends of the development in the title since those agents with target properties are awaited for specific organ and regional MRI. The contrast agents alter the relaxation time of water proton to yield the enhanced contrast between organs and tissues with different water volumes. Nowadays Gd-complexes and nano-particle of superparamagnetic iron oxide (Fe(III)) are widely used for enhancing in clinic. Among organic compounds with paramagnetic spin, those possessing nitroxide radical like TEMPO- and PROXYL-radicals have been subject to development by their derivatization. High spin molecules conceivably affect the relaxivity, which, however, is found smaller per spin of synthesized triplet complexes than doublet ones. This has lead to basic approach for molecules restricting water movement due to their hydrogen bond like DNA as a model, for introducing many radicals in high molecular weight compounds, and their polymer, as one of which authors have developed a derivative of hyperbranched polymer (HPS)-TEMPO having the similar relaxivity to gadolinium-diethylenetiamine pentaacetid acid (Gd-DTPA) (R.T.)

  17. Extracellular gadolinium contrast agents: Differences in stability

    International Nuclear Information System (INIS)

    Morcos, S.K.

    2008-01-01

    Extracellular gadolinium contrast agents (Gd-CA) are either linear or macrocyclic chelates available as ionic or non-ionic preparations. The molecular structure whether cyclic or linear and ionicity determines the stability of Gd-CA. Linear chelates are flexible open chains which do not offer a strong binding to Gd 3+ . In contrast, the macrocyclic chelates offer a strong binding to Gd 3+ by the virtue of being preorganized rigid rings of almost optimal size to cage the gadolinium atom. Non-ionic preparations are also less stable in comparison to the ionic ones as the binding between Gd 3+ with the negatively charged carboxyl groups is stronger in comparison to that with amides or alcohol in the non-ionic preparations. According to stability constants and kinetic measurements, the most stable Gd-CM is the ionic-macrocyclic chelate Gd-DOTA and the least stable agents are the non-ionic linear chelates gadodiamide and gadoversetamide. In vivo data confirmed the low stability of non-ionic linear chelates but no significant difference was observed amongst the macrocyclic agents whether ionic (Gd-DOTA) or non-ionic such as Gd-HP-DO3A and Gd-BT-DO3A. The stability of Gd-CA seems to be an important factor in the pathogenesis of the serious complication of nephrogenic systemic fibrosis. Gd-CA of low stability are likely to undergo transmetallation and release free Gd ions that deposit in tissue and attract circulating fibrocytes to initiate the process of fibrosis. No cases of NSF have been observed so far after the exclusive use of the stable macrocyclic Gd-CA

  18. On the relationship between microbubble fragmentation, deflation and broadband superharmonic signal production.

    Science.gov (United States)

    Lindsey, Brooks D; Rojas, Juan D; Dayton, Paul A

    2015-06-01

    Acoustic angiography imaging of microbubble contrast agents uses the superharmonic energy produced from excited microbubbles and enables high-contrast, high-resolution imaging. However, the exact mechanism by which broadband harmonic energy is produced is not fully understood. To elucidate the role of microbubble shell fragmentation in superharmonic signal production, simultaneous optical and acoustic measurements were performed on individual microbubbles at transmit frequencies from 1.75 to 3.75 MHz and pressures near the shell fragmentation threshold for microbubbles of varying diameter. High-amplitude, broadband superharmonic signals were produced with shell fragmentation, whereas weaker signals (approximately 25% of peak amplitude) were observed in the presence of shrinking bubbles. Furthermore, when populations of stationary microbubbles were imaged with a dual-frequency ultrasound imaging system, a sharper decline in image intensity with respect to frame number was observed for 1-μm bubbles than for 4-μm bubbles. Finally, in a study of two rodents, increasing frame rate from 4 to 7 Hz resulted in decreases in mean steady-state image intensity of 27% at 1000 kPa and 29% at 1300 kPa. Although the existence of superharmonic signals when bubbles shrink has the potential to prolong the imaging efficacy of microbubbles, parameters such as frame rate and peak pressure must be balanced with expected re-perfusion rate to maintain adequate contrast during in vivo imaging. Copyright © 2015. Published by Elsevier Inc.

  19. Microbubbles as drug delivery systems in cerebrovascular diseases.

    Science.gov (United States)

    Spinelli, Mariacarmela; Demitri, Christian; Sannino, Alessandro; Peruzzotti-Jametti, Luca; Bacigaluppi, Marco; Comi, Giancarlo; Corea, Francesco

    2009-11-01

    The field of neurovascular ultrasound is growing rapidly with new applications. While ultrasound contrast agents were initially used to overcome poor transcranial bone windows for identification of cerebral arteries, newgeneration microbubbles in combination with innovative contrast-specific ultrasound techniques now enable potential therapeutic procedures. This article will provide a review of recent and emerging developments along with patents in ultrasound technology and contrast-specific therapeutic techniques for cerebrovascular patients.

  20. Method and apparatus to characterize ultrasonically reflective contrast agents

    Science.gov (United States)

    Pretlow, Robert A., III (Inventor)

    1993-01-01

    A method and apparatus for characterizing the time and frequency response of an ultrasonically reflective contrast agent is disclosed. An ultrasonically reflective contrast agent is injected, under constant pressure, into a fluid flowing through a pump flow circuit. The fluid and the ultrasonically reflective contrast agent are uniformly mixed in a mixing chamber, and the uniform mixture is passed through a contrast agent chamber. The contrast agent chamber is acoustically and axially interposed between an ultrasonic transducer chamber and an acoustic isolation chamber. A pulse of ultrasonic energy is transmitted into the contrast agent chamber from the ultrasonic transducer chamber. An echo waveform is received from the ultrasonically reflective contrast agent, and it is analyzed to determine the time and frequency response of the ultrasonically reflective contrast agent.

  1. MRI contrast agents from molecules to particles

    CERN Document Server

    Laurent, Sophie; Stanicki, Dimitri; Boutry, Sébastien; Lipani, Estelle; Belaid, Sarah; Muller, Robert N; Vander Elst, Luce

    2017-01-01

    This book describes the multiple aspects of (i) preparation of the magnetic core, (ii) the stabilization with different coatings, (iii) the physico-chemical characterization and (iv) the vectorization to obtain specific nanosystems. Several bio-applications are also presented in this book. In the early days of Magnetic Resonance Imaging (MRI), paramagnetic ions were proposed as contrast agents to enhance the diagnostic quality of MR images. Since then, academic and industrial efforts have been devoted to the development of new and more efficient molecular, supramolecular and nanoparticular systems. Old concepts and theories, like paramagnetic relaxation, were revisited and exploited, leading to new scientific tracks. With their high relaxivity payload, the superparamagnetic nanoparticles are very appealing in the context of molecular imaging but challenges are still numerous: absence of toxicity, specificity, ability to cross the biological barriers, etc. .

  2. Trends and developments in MRI contrast agent research

    International Nuclear Information System (INIS)

    Cavagna, F.M.; Dapra, M.; Castelli, P.M.; Maggioni, F.; Kirchin, M.A.

    1997-01-01

    The currently prevailing trends in industrial contrast agent research for MRI are discussed. Specific mention is made of contrast agents for liver imaging using both static and delayed procedures, of the potential for blood pool agents and the form such agents may take, and of the ultimate challenge for contrast agent R and D: tissue-targeting in a wider sense to both normal and pathologic tissues. (orig.)

  3. Simulation of microbubble response to ambient pressure changes

    DEFF Research Database (Denmark)

    Andersen, Klaus Scheldrup; Jensen, Jørgen Arendt

    2008-01-01

    The theory on microbubbles clearly indicates a relation between the ambient pressure and the acoustic behavior of the bubble. The purpose of this study was to optimize the sensitivity of ambient pressure measurements, using the subharmonic component, through microbubble response simulations....... The behaviour of two different contrast agents was investigated as a function of driving pulse and ambient overpressure, pov. Simulations of Levovist using a rectangular driving pulse show an almost linear reduction in the subharmonic component as pov is increased. For a 20 cycles driving pulse, a reduction...... is not completely linear as a function of the ambient pressure....

  4. Ultrasound contrast agent imaging: Real-time imaging of the superharmonics

    Energy Technology Data Exchange (ETDEWEB)

    Peruzzini, D.; Viti, J. [MSD lab, Department of Information Engineering, Univ of Florence, Via S.Marta, 3, 50139 Firenze (Italy); Erasmus MC, ’s-Gravendijkwal 230, Faculty Building, Ee 2302, 3015 CE Rotterdam (Netherlands); Tortoli, P. [MSD lab, Department of Information Engineering, Univ of Florence, Via S.Marta, 3, 50139 Firenze (Italy); Verweij, M. D. [Acoustical Wavefield Imaging, ImPhys, Delft Univ Technology, van der Waalsweg 8, 2628 CH Delft (Netherlands); Jong, N. de; Vos, H. J., E-mail: h.vos@erasmusmc.nl [Erasmus MC, ’s-Gravendijkwal 230, Faculty Building, Ee 2302, 3015 CE Rotterdam (Netherlands); Acoustical Wavefield Imaging, ImPhys, Delft Univ Technology, van der Waalsweg 8, 2628 CH Delft (Netherlands)

    2015-10-28

    Currently, in medical ultrasound contrast agent (UCA) imaging the second harmonic scattering of the microbubbles is regularly used. This scattering is in competition with the signal that is caused by nonlinear wave propagation in tissue. It was reported that UCA imaging based on the third or higher harmonics, i.e. “superharmonic” imaging, shows better contrast. However, the superharmonic scattering has a lower signal level compared to e.g. second harmonic signals. This study investigates the contrast-to-tissue ratio (CTR) and signal to noise ratio (SNR) of superharmonic UCA scattering in a tissue/vessel mimicking phantom using a real-time clinical scanner. Numerical simulations were performed to estimate the level of harmonics generated by the microbubbles. Data were acquired with a custom built dual-frequency cardiac phased array probe. Fundamental real-time images were produced while beam formed radiofrequency (RF) data was stored for further offline processing. The phantom consisted of a cavity filled with UCA surrounded by tissue mimicking material. The acoustic pressure in the cavity of the phantom was 110 kPa (MI = 0.11) ensuring non-destructivity of UCA. After processing of the acquired data from the phantom, the UCA-filled cavity could be clearly observed in the images, while tissue signals were suppressed at or below the noise floor. The measured CTR values were 36 dB, >38 dB, and >32 dB, for the second, third, and fourth harmonic respectively, which were in agreement with those reported earlier for preliminary contrast superharmonic imaging. The single frame SNR values (in which ‘signal’ denotes the signal level from the UCA area) were 23 dB, 18 dB, and 11 dB, respectively. This indicates that noise, and not the tissue signal, is the limiting factor for the UCA detection when using the superharmonics in nondestructive mode.

  5. Comparison between maximum radial expansion of ultrasound contrast agents and experimental postexcitation signal results.

    Science.gov (United States)

    King, Daniel A; O'Brien, William D

    2011-01-01

    Experimental postexcitation signal data of collapsing Definity microbubbles are compared with the Marmottant theoretical model for large amplitude oscillations of ultrasound contrast agents (UCAs). After taking into account the insonifying pulse characteristics and size distribution of the population of UCAs, a good comparison between simulated results and previously measured experimental data is obtained by determining a threshold maximum radial expansion (Rmax) to indicate the onset of postexcitation. This threshold Rmax is found to range from 3.4 to 8.0 times the initial bubble radius, R0, depending on insonification frequency. These values are well above the typical free bubble inertial cavitation threshold commonly chosen at 2R0. The close agreement between the experiment and models suggests that lipid-shelled UCAs behave as unshelled bubbles during most of a large amplitude cavitation cycle, as proposed in the Marmottant equation.

  6. Augmentation of limb perfusion and reversal of tissue ischemia produced by ultrasound-mediated microbubble cavitation.

    Science.gov (United States)

    Belcik, J Todd; Mott, Brian H; Xie, Aris; Zhao, Yan; Kim, Sajeevani; Lindner, Nathan J; Ammi, Azzdine; Linden, Joel M; Lindner, Jonathan R

    2015-04-01

    Ultrasound can increase tissue blood flow, in part, through the intravascular shear produced by oscillatory pressure fluctuations. We hypothesized that ultrasound-mediated increases in perfusion can be augmented by microbubble contrast agents that undergo ultrasound-mediated cavitation and sought to characterize the biological mediators. Contrast ultrasound perfusion imaging of hindlimb skeletal muscle and femoral artery diameter measurement were performed in nonischemic mice after unilateral 10-minute exposure to intermittent ultrasound alone (mechanical index, 0.6 or 1.3) or ultrasound with lipid microbubbles (2×10(8) IV). Studies were also performed after inhibiting shear- or pressure-dependent vasodilator pathways, and in mice with hindlimb ischemia. Ultrasound alone produced a 2-fold increase (Pultrasound power. Ultrasound-mediated augmentation in flow was greater with microbubbles (3- and 10-fold higher than control for mechanical index 0.6 and 1.3, respectively; Pultrasound and microbubbles by 70% (Pultrasound and ultrasound with microbubbles. In mice with unilateral hindlimb ischemia (40%-50% reduction in flow), ultrasound (mechanical index, 1.3) with microbubbles increased perfusion by 2-fold to a degree that was greater than the control nonischemic limb. Increases in muscle blood flow during high-power ultrasound are markedly amplified by the intravascular presence of microbubbles and can reverse tissue ischemia. These effects are most likely mediated by cavitation-related increases in shear and activation of endothelial nitric oxide synthase. © 2015 American Heart Association, Inc.

  7. Dendrimer-based Macromolecular MRI Contrast Agents: Characteristics and Application

    Directory of Open Access Journals (Sweden)

    Hisataka Kobayashi

    2003-01-01

    Full Text Available Numerous macromolecular MRI contrast agents prepared employing relatively simple chemistry may be readily available that can provide sufficient enhancement for multiple applications. These agents operate using a ~100-fold lower concentration of gadolinium ions in comparison to the necessary concentration of iodine employed in CT imaging. Herein, we describe some of the general potential directions of macromolecular MRI contrast agents using our recently reported families of dendrimer-based agents as examples. Changes in molecular size altered the route of excretion. Smaller-sized contrast agents less than 60 kDa molecular weight were excreted through the kidney resulting in these agents being potentially suitable as functional renal contrast agents. Hydrophilic and larger-sized contrast agents were found better suited for use as blood pool contrast agents. Hydrophobic variants formed with polypropylenimine diaminobutane dendrimer cores created liver contrast agents. Larger hydrophilic agents are useful for lymphatic imaging. Finally, contrast agents conjugated with either monoclonal antibodies or with avidin are able to function as tumor-specific contrast agents, which also might be employed as therapeutic drugs for either gadolinium neutron capture therapy or in conjunction with radioimmunotherapy.

  8. Contrast agents for cardiac angiography: effects of a nonionic agent vs. a standard ionic agent

    International Nuclear Information System (INIS)

    Bettmann, M.A.; Bourdillon, P.D.; Barry, W.H.; Brush, K.A.; Levin, D.C.

    1984-01-01

    The effects on cardiac hemodynamics and of a standard contrast agent, sodium methylglucamine diatrizoate [Renografin 76] were compared with the effects of a new nonionic agent (iohexol) in a double-blind study in 51 patietns undergoing coronary angiography and left ventriculography. No significant alteration in measured blood parameters occurred with either contrast agent. Hemodynamic changes occurred with both, but were significantly greater with the standard renografin than with the low-osmolality, nonionic iohexol. After left ventriculography, heart rate increased and peripheral arterial pressure fell with both agents, but less with iohexol. It is concluded that iohexol causes less alteration in cardiac function than does the agent currently most widely used. Nonionic contrast material is likely to improve the safety of coronary angiography, particularly in those patients at greatest risk

  9. Fundamental study of DSA images using gadolinium contrast agent

    International Nuclear Information System (INIS)

    Nagashima, Hiroyuki; Shiraishi, Akihisa; Igarashi, Hitoshi; Sakamoto, Hajime; Sano, Yoshitomo

    2002-01-01

    Most contrast agents used in digital subtraction angiography (DSA) are non-ionic iodinated contrast agents, which can cause severe side effects in patients with contraindications for iodine or allergic reactions to iodine. Therefore, DSA examinations using carbon dioxide gas or examinations done by magnetic resonance imaging (MRI) and ultrasound (US) were carried out in these patients. However, none of these examinations provided mages as clear as those of DSA with an iodinated contrast agent. We experienced DSA examination using a gadolinium contrast agent in a patient contraindicated for iodine. The patient had undergone MRI examination with a gadolinium contrast agent previously without side effects. The characteristics of gadolinium and the iodinated contrast agent were compared, and the DSA images obtained clinically using these media were also evaluated. The signal-to-noise (SN) ratio of the gadolinium contrast agent was the highest at tube voltages of 70 to 80 kilovolts and improved slightly when the image intensifier (I.I.) entrance dose was greater than 300 μR (77.4 nC/kg). The dilution ratios of five iodinated contrast agents showed the same S/N value as the undiluted gadolinium contrast agent. Clinically, the images obtained showed a slight decrease in contrast but provided the data necessary to make a diagnosis and made it possible to obtain interventional radiology (IVR) without any side effects. DSA examinations using a gadolinium contrast agent have some benefit with low risk and are thought to be useful for patients contraindicated for iodine. (author)

  10. Quantitative Differences Between the First and Second Injection of Contrast Agent in Contrast-Enhanced Ultrasonography of Feline Kidneys and Spleen.

    Science.gov (United States)

    Stock, Emmelie; Vanderperren, Katrien; Haers, Hendrik; Duchateau, Luc; Hesta, Myriam; Saunders, Jimmy H

    2017-02-01

    Contrast-enhanced ultrasound is a valuable and safe technique for the evaluation of organ perfusion. Repeated injections of ultrasound contrast agent are often administered during the same imaging session. However, it remains unclear if quantitative differences are present between the consecutive microbubble injections. Therefore, the first and second injection of contrast agent for the left renal cortex, renal medulla and the splenic parenchyma in healthy cats were compared. A lower peak intensity and area under the curve were observed for the first injection of contrast agent in the feline kidney, both for the renal cortex and medulla, and spleen. Moreover, for the renal cortex, the time-intensity curve was steeper after the second injection. Findings from the present study demonstrate that a second injection of contrast agent provides stronger enhancement. The exact mechanism behind our findings remains unclear; however, saturation of the lung macrophages is believed to play an important role. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  11. A novel microbubble construct for intracardiac or intravascular MR manometry: a theoretical study

    International Nuclear Information System (INIS)

    Dharmakumar, Rohan; Plewes, Donald B; Wright, Graham A

    2005-01-01

    It has been demonstrated that gas-filled microbubble contrast agents, based on their volume changes, can serve as pressure probes in an MR field. It was recently reported that such an MR-based pressure measurement with microbubbles at 1.5 T must make use of microbubbles that have a volumetric magnetic susceptibility difference with the blood of at least 34 ppm in SI units. In this work, we show through analytical approximations and numerical simulations that such a microbubble formulation can be achieved by coating typical lipid-shelled microbubbles with particles of high dipole moment. Through finite-element simulations we demonstrate that the effective volumetric magnetic susceptibility of a coated microbubble is dependent on the radius, the shell volume fraction and the magnetic susceptibility of the particulates on the shell. Our calculations suggest that a suitable microbubble formulation which will be MR-sensitive to small pressure changes at 1.5 T must be 2-3 μm in radius and be uniformly coated with single-domain magnetic nanoparticles, such as magnetite, at shell volume fractions below 5%

  12. WE-D-210-04: Radiation-Induced Polymerization of Ultrasound Contrast Agents in View of Non-Invasive Dosimetry in External Beam Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Callens, M; Verboven, E; Van Den Abeele, K [Department of Physics, Wave Propagation and Signal Processing, KU Leuven KULAK, Kortrijk (Belgium); D’Agostino, E [DoseVue NV, Hasselt (Belgium); Pfeiffer, H [Department of Materials Engineering, KU Leuven, Leuven (Belgium); D’hooge, J [Department of Cardiovascular Sciences, Bio-Medical Science Group, KU Leuven, Leuven (Belgium)

    2015-06-15

    Purpose: Ultrasound contrast agents (UCA’s) based on gas-filled microbubbles encapsulated by an amphiphilic shell are well established as safe and effective echo-enhancers in diagnostic imaging. In view of an alternative application of UCA’s, we investigated the use of targeted microbubbles as radiation sensors for external beam radiation therapy. As radiation induces permanent changes in the microbubble’s physico-chemical properties, a robust measure of these changes can provide a direct or indirect estimate of the applied radiation dose. For instance, by analyzing the ultrasonic dispersion characteristics of microbubble distributions before and after radiation treatment, an estimate of the radiation dose at the location of the irradiated volume can be made. To increase the radiation sensitivity of microbubbles, polymerizable diacetylene molecules can be incorporated into the shell. This study focuses on characterizing the acoustic response and quantifying the chemical modifications as a function of radiation dose. Methods: Lipid/diacetylene microbubbles were irradiated with a 6 MV photon beam using dose levels in the range of 0–150 Gy. The acoustic response of the microbubbles was monitored by ultrasonic through-transmission measurements in the range of 500 kHz to 20 MHz, thereby providing the dispersion relations of the phase velocity, attenuation and nonlinear coefficient. In addition, the radiation-induced chemical modifications were quantified using UV-VIS spectroscopy. Results: UV-VIS spectroscopy measurements indicate that ionizing radiation induces the polymerization of diacetylenes incorporated in the microbubble shell. The polymer yield strongly depends on the shell composition and the radiation-dose. The acoustic response is inherently related to the visco-elastic properties of the shell and is strongly influenced by the shell composition and the physico-chemical changes in the environment. Conclusion: Diacetylene-containing microbubbles are

  13. Evaluation of oral abdominal contrast agent containing ferric ammonium citrate

    International Nuclear Information System (INIS)

    Shiga, Toshiko; Kawamura, Yasutaka; Iwasaki, Toshiko

    1991-01-01

    We evaluated the effectiveness of oral MRI contrast agent containing ferric ammonium citrate. Twenty patients were arbitrarily divided into 2 groups according to the given dose of 100 and 200 mg Fe of oral MRI contrast agent. MRI was performed before and immediately after ingesting 300 ml solution of oral MRI contrast agent using a 1.5 T superconducting system (GE: Signa). Each dose of 100 and 200 mg Fe of oral MRI contrast agent produced sufficient enhancement of gastrointestinal tract, enough to make clear the pancreatic contour and porta hepatis. There was no significant change in blood and urine analysis observed after taking oral MRI contrast agent. The use of ferric ammonium citrate as an oral MRI contrast agent seems to add valuable information in performing upper abdominal MRI imaging. (author)

  14. Microbubbles in macrocysts - Contrast-enhanced ultrasound assisted sclerosant therapy of a congenital macrocystic lymphangioma: a case report.

    Science.gov (United States)

    Menendez-Castro, Carlos; Zapke, Maren; Fahlbusch, Fabian; von Goessel, Heiko; Rascher, Wolfgang; Jüngert, Jörg

    2017-07-06

    Congenital cystic lymphangiomas are benign malformations due to a developmental disorder of lymphatic vessels. Besides surgical excision, sclerosant therapy of these lesions by intracavitary injection of OK-432 (Picibanil®), a lyophilized mixture of group A Streptococcus pyogenes, is a common therapeutical option. For an appropriate application of OK-432, a detailed knowledge about the structure and composition of the congenital cystic lymphangioma is essential. SonoVue® is a commercially available contrast agent commonly used in sonography by intravenous and intracavitary application. Here we report the case of 2 month old male patient with a large thoracic congenital cystic lymphangioma. Preinterventional imaging of the malformation was performed by contrast-enhanced ultrasound after intracavitary application of SonoVue® immediately followed by a successful sclerotherapy with OK-432. Contrast agent-enhanced ultrasound imaging offers a valuable option to preinterventionally clarify the anatomic specifications of a congenital cystic lymphangioma in more detail than by single conventional sonography. By the exact knowledge about the composition and especially about the intercystic communications of the lymphangioma sclerosant therapy becomes safer and more efficient.

  15. Iodinated contrast media and contrast-induced nephropathy: is there a preferred cost-effective agent?

    Science.gov (United States)

    Sharma, Samin K

    2008-05-01

    Over 20 years have passed since the introduction of the tri-iodinated low-osmolar nonionic contrast agents such as iopamidol, iohexol, ioversol and iopromide. During this time, most cardiology practices have switched to these nonionic agents to avoid the nuisance side effects and cardiac adverse events associated with the older ionic contrast agents. Although the improved tolerability of the nonionic agents is generally attributed to their decreased osmolality (approximately half that of the older ionic contrast agents), in fact, these contrast agents also differ from the older agents in their ionicity, viscosity and direct chemotoxicity. The impact of these properties on safety, together with cost differences, should be considered when selecting a contrast agent.

  16. Gadolinium-based contrast agents in pediatric magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Gale, Eric M.; Caravan, Peter [Massachusetts General Hospital, Harvard Medical School, Department of Radiology, The Martinos Center for Biomedical Imaging, Boston, MA (United States); Rao, Anil G. [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); McDonald, Robert J. [College of Medicine, Mayo Clinic, Department of Radiology, Rochester, MN (United States); Winfeld, Matthew [University of Pennsylvania Perelman School of Medicine, Philadelphia, PA (United States); Fleck, Robert J. [Cincinnati Children' s Hospital Medical Center, Department of Pediatric Radiology, Cincinnati, OH (United States); Gee, Michael S. [MassGeneral Hospital for Children, Harvard Medical School, Division of Pediatric Imaging, Department of Radiology, Boston, MA (United States)

    2017-05-15

    Gadolinium-based contrast agents can increase the accuracy and expediency of an MRI examination. However the benefits of a contrast-enhanced scan must be carefully weighed against the well-documented risks associated with administration of exogenous contrast media. The purpose of this review is to discuss commercially available gadolinium-based contrast agents (GBCAs) in the context of pediatric radiology. We discuss the chemistry, regulatory status, safety and clinical applications, with particular emphasis on imaging of the blood vessels, heart, hepatobiliary tree and central nervous system. We also discuss non-GBCA MRI contrast agents that are less frequently used or not commercially available. (orig.)

  17. Magnetic resonance imaging contrast agents: Overview and perspectives

    International Nuclear Information System (INIS)

    Yan Guoping; Robinson, Leslie; Hogg, Peter

    2007-01-01

    Magnetic resonance imaging (MRI) is a non-invasive clinical imaging modality, which has become widely used in the diagnosis and/or staging of human diseases around the world. Some MRI examinations include the use of contrast agents. The categorizations of currently available contrast agents have been described according to their effect on the image, magnetic behavior and biodistribution in the body, respectively. In this field, superparamagnetic iron oxide particles and soluble paramagnetic metal chelates are two main classes of contrast agents for MRI. This review outlines the research and development of MRI contrast agents. In future, the ideal MRI contrast agent will be focused on the neutral tissue- or organ-targeting materials with high relaxivity and specificity, low toxicity and side effects, suitable long intravascular duration and excretion time, high contrast enhancement with low dose in vivo, and with minimal cost

  18. Phase change events of volatile liquid perfluorocarbon contrast agents produce unique acoustic signatures

    International Nuclear Information System (INIS)

    Sheeran, Paul S; Dayton, Paul A; Matsunaga, Terry O

    2014-01-01

    Phase-change contrast agents (PCCAs) provide a dynamic platform to approach problems in medical ultrasound (US). Upon US-mediated activation, the liquid core vaporizes and expands to produce a gas bubble ideal for US imaging and therapy. In this study, we demonstrate through high-speed video microscopy and US interrogation that PCCAs composed of highly volatile perfluorocarbons (PFCs) exhibit unique acoustic behavior that can be detected and differentiated from standard microbubble contrast agents. Experimental results show that when activated with short pulses PCCAs will over-expand and undergo unforced radial oscillation while settling to a final bubble diameter. The size-dependent oscillation phenomenon generates a unique acoustic signal that can be passively detected in both time and frequency domain using confocal piston transducers with an ‘activate high’ (8 MHz, 2 cycles), ‘listen low’ (1 MHz) scheme. Results show that the magnitude of the acoustic ‘signature’ increases as PFC boiling point decreases. By using a band-limited spectral processing technique, the droplet signals can be isolated from controls and used to build experimental relationships between concentration and vaporization pressure. The techniques shown here may be useful for physical studies as well as development of droplet-specific imaging techniques. (paper)

  19. Nanoparticle Contrast Agents for Computed Tomography: A Focus on Micelles

    Science.gov (United States)

    Cormode, David P.; Naha, Pratap C.; Fayad, Zahi A.

    2014-01-01

    Computed tomography (CT) is an X-ray based whole body imaging technique that is widely used in medicine. Clinically approved contrast agents for CT are iodinated small molecules or barium suspensions. Over the past seven years there has been a great increase in the development of nanoparticles as CT contrast agents. Nanoparticles have several advantages over small molecule CT contrast agents, such as long blood-pool residence times, and the potential for cell tracking and targeted imaging applications. Furthermore, there is a need for novel CT contrast agents, due to the growing population of renally impaired patients and patients hypersensitive to iodinated contrast. Micelles and lipoproteins, a micelle-related class of nanoparticle, have notably been adapted as CT contrast agents. In this review we discuss the principles of CT image formation and the generation of CT contrast. We discuss the progress in developing non-targeted, targeted and cell tracking nanoparticle CT contrast agents. We feature agents based on micelles and used in conjunction with spectral CT. The large contrast agent doses needed will necessitate careful toxicology studies prior to clinical translation. However, the field has seen tremendous advances in the past decade and we expect many more advances to come in the next decade. PMID:24470293

  20. Neuroimaging: do we really need new contrast agents for MRI?

    International Nuclear Information System (INIS)

    Roberts, T.P.L.; Chuang, N.; Roberts, H.C.

    2000-01-01

    The use of exogenous contrast media in magnetic resonance imaging of the brain has brought dramatic improvement in the sensitivity of detection and delineation of pathological structures, such as primary and metastatic brain tumors, inflammation and ischemia. Disruption of the blood brain barrier leads to accumulation of the intravenously injected contrast material in the extravascular space, leading to signal enhancement. Magnetic resonance angiography benefits from T 1 -shortening effects of contrast agent, improving small vessel depiction and providing vascular visualization even in situations of slow flow. High speed dynamic MRI after bolus injection of contrast media allows tracer kinetic modeling of cerebral perfusion. Progressive enhancement over serial post-contrast imaging allows modeling of vascular permeability and thus quantitative estimation of the severity of blood brain barrier disruption. With such an array of capabilities and ever improving technical abilities, it seems that the role of contrast agents in MR neuroimaging is established and the development of new agents may be superfluous. However, new agents are being developed with prolonged intravascular residence times, and with in-vivo binding of ever-increasing specificity. Intravascular, or blood pool, agents are likely to benefit magnetic resonance angiography of the carotid and cerebral vessels; future agents may allow the visualization of therapeutic drug delivery, the monitoring of, for example, gene expression, and the imaging evaluation of treatment efficacy. So while there is a substantial body of work that can be performed with currently available contrast agents, especially in conjunction with optimized image acquisition strategies, post processing, and mathematical analysis, there are still unrealized opportunities for novel contrast agent introduction, particularly those exploiting biological specificity. This article reviews the current use of contrast media in magnetic resonance

  1. Contrast-Enhanced Ultrasound with VEGFR2-Targeted Microbubbles for Monitoring Regorafenib Therapy Effects in Experimental Colorectal Adenocarcinomas in Rats with DCE-MRI and Immunohistochemical Validation.

    Directory of Open Access Journals (Sweden)

    Ralf Stefan Eschbach

    Full Text Available To investigate contrast-enhanced ultrasound (CEUS with VEGFR2-targeted microbubbles for monitoring therapy effects of regorafenib on experimental colon carcinomas in rats with correlation to dynamic contrast-enhanced MRI (DCE-MRI and immunohistochemistry.Human colorectal adenocarcinoma xenografts (HT-29 were implanted subcutaneously in n = 21 (n = 11 therapy group; n = 10 control group female athymic nude rats (Hsd: RH-Foxn1rnu. Animals were imaged at baseline and after a one-week daily treatment with regorafenib or a placebo (10 mg/kg bodyweight, using CEUS with VEGFR2-targeted microbubbles and DCE-MRI. In CEUS tumor perfusion was assessed during an early vascular phase (wash-in area under the curve = WiAUC and VEGFR2-specific binding during a late molecular phase (signal intensity after 8 (SI8min and 10 minutes (SI10min, using a conventional 15L8 linear transducer (transmit frequency 7 MHz, dynamic range 80 dB, depth 25 mm. In DCE-MRI functional parameters plasma flow (PF and plasma volume (PV were quantified. For validation purposes, CEUS parameters were correlated with DCE-MRI parameters and immunohistochemical VEGFR2, CD31, Ki-67 and TUNEL stainings.CEUS perfusion parameter WiAUC decreased significantly (116,989 ± 77,048 a.u. to 30,076 ± 27,095a.u.; p = 0.005 under therapy with no significant changes (133,932 ± 65,960 a.u. to 84,316 ± 74,144 a.u.; p = 0.093 in the control group. In the therapy group, the amount of bound microbubbles in the late phase was significantly lower in the therapy than in the control group on day 7 (SI8min: 283 ± 191 vs. 802 ± 460 a.u.; p = 0.006; SI10min: 226 ± 149 vs. 645 ± 461 a.u.; p = 0.009. PF and PV decreased significantly (PF: 147 ± 58 mL/100 mL/min to 71 ± 15 mL/100 mL/min; p = 0.003; PV: 13 ± 3% to 9 ± 4%; p = 0.040 in the therapy group. Immunohistochemistry revealed significantly fewer VEGFR2 (7.2 ± 1.8 vs. 17.8 ± 4.6; p < 0.001, CD31 (8.1 ± 3.0 vs. 20.8 ± 5.7; p < 0.001 and Ki-67 (318.7

  2. Hepatobiliary contrast agents for contrast-enhanced MRI of the liver: properties, clinical development and applications

    International Nuclear Information System (INIS)

    Reimer, Peter; Schneider, Guenter; Schima, Wolfgang

    2004-01-01

    Hepatobiliary contrast agents with uptake into hepatocytes followed by variable biliary excretion represent a unique class of cell-specific MR contrast agents. Two hepatobiliary contrast agents, mangafodipir trisodium and gadobenate dimeglumine, are already clinically approved. A third hepatobiliary contrast agent, Gd-EOB-DTPA, is under consideration. The purpose of this review is to provide an overview on the properties, clinical development and application of these three hepatobiliary contrast agents. Bolus injectable paramagnetic hepatobiliary contrast agents combine established features of extracellular agents with the advantages of hepatocyte specificity. The detection and characterisation of focal liver disease appears to be improved compared to unenhanced MRI, MRI with unspecific contrast agents and contrast-enhanced CT. To decrease the total time spent by a patient in the MR scanner, it is advisable to administer the agent immediately after acquisition of unenhanced T1-w MRI. After infusion or bolus injection (with dynamic FS-T1-w 2D or 3D GRE) of the contrast agent, moderately and heavily T2w images are acquired. Post-contrast T1-w MRI is started upon completion of T2-w MRI for mangafodipir trisodium and Gd-EOB-DTPA as early as 20 min following injection, while gadobenate dimeglumine scans are obtained >60 min following injection. Post-contrast acquisition techniques with near isotropic 3D pulse sequences with fat saturation parallel the technical progress made by MSCT combined with an unparalleled improvement in tumour-liver contrast. The individual decision that hepatobiliary contrast agent one uses is partly based on personal preferences. No comparative studies have been conducted comparing the advantages or disadvantages of all three agents directly against each other. (orig.)

  3. Magnetic Resonance Imaging Contrast Agents: A Review of Literature

    Directory of Open Access Journals (Sweden)

    Zahra Sahraei

    2015-10-01

    Full Text Available  Magnetic Resonance Imaging (MRI contrast agents most commonly agents used in diagnosing different diseases. Several agents have been ever introduced with different peculiar characteristics. They vary in potency, adverse reaction and other specification, so it is important to select the proper agent in different situations. We conducted a systematic literature search in MEDLINE/PUBMED, Web of Science (ISI, Scopus,Google Scholar by using keywords "gadolinium" and "MRI contrast Medias", "Gadofosvest", "Gadobenate" and "Gadoxetate". The most frequent contrast media agents made based on gadolinium (Gd. These are divided into two categories based on the structure of their chelating parts, linear agents and macrocyclic agents. All characteristics of contrast media factors, including efficiency, kinetic properties, stability, side effects and the rate of resolution are directly related to the structure of chelating part of that formulation.In vitro data has shown that the macrocyclic compounds are the most stable Gd-CA as they do not bind to serum proteins, they all possess similar and relatively low relaxivity and the prevalence of Nephrogenic Systemic Fibrosis (NSF has decreased by increasing the use of macrocyclic agents in recent years. No cases of NSF have been recorded after the administration of any of the high-relaxivity protein interacting agents, the vascular imaging agent gadofosveset trisodium (Ablavar, the hepatic imaging agent gadoxetate meglumine (Eovist, and the multipurpose agent gadobenate dimeglumine (MultiHance. In pregnancy and lactating women, stable macrocyclic agent is recommended.

  4. Ultrasound imaging of the mouse pancreatic duct using lipid microbubbles

    Science.gov (United States)

    Banerjee, B.; McKeown, K. R.; Skovan, B.; Ogram, E.; Ingram, P.; Ignatenko, N.; Paine-Murrieta, G.; Witte, R.; Matsunaga, T. O.

    2012-03-01

    Research requiring the murine pancreatic duct to be imaged is often challenging due to the difficulty in selectively cannulating the pancreatic duct. We have successfully catheterized the pancreatic duct through the common bile duct in severe combined immune deficient (SCID) mice and imaged the pancreatic duct with gas filled lipid microbubbles that increase ultrasound imaging sensitivity due to exquisite scattering at the gas/liquid interface. A SCID mouse was euthanized by CO2, a midline abdominal incision made, the common bile duct cut at its midpoint, a 2 cm, 32 gauge tip catheter was inserted about 1 mm into the duct and tied with suture. The duodenum and pancreas were excised, removed in toto, embedded in agar and an infusion pump was used to instill normal saline or lipid-coated microbubbles (10 million / ml) into the duct. B-mode images before and after infusion of the duct with microbubbles imaged the entire pancreatic duct (~ 1 cm) with high contrast. The microbubbles were cavitated by high mechanical index (HMI) ultrasound for imaging to be repeated. Our technique of catheterization and using lipid microbubbles as a contrast agent may provide an effective, affordable technique of imaging the murine pancreatic duct; cavitation with HMI ultrasound would enable repeated imaging to be performed and clustering of targeted microbubbles to receptors on ductal cells would allow pathology to be localized accurately. This research was supported by the Experimental Mouse Shared Service of the AZ Cancer Center (Grant Number P30CA023074, NIH/NCI and the GI SPORE (NIH/NCI P50 CA95060).

  5. Basic MR relaxation mechanisms and contrast agent design.

    Science.gov (United States)

    De León-Rodríguez, Luis M; Martins, André F; Pinho, Marco C; Rofsky, Neil M; Sherry, A Dean

    2015-09-01

    The diagnostic capabilities of magnetic resonance imaging (MRI) have undergone continuous and substantial evolution by virtue of hardware and software innovations and the development and implementation of exogenous contrast media. Thirty years since the first MRI contrast agent was approved for clinical use, a reliance on MR contrast media persists, largely to improve image quality with higher contrast resolution and to provide additional functional characterization of normal and abnormal tissues. Further development of MR contrast media is an important component in the quest for continued augmentation of diagnostic capabilities. In this review we detail the many important considerations when pursuing the design and use of MR contrast media. We offer a perspective on the importance of chemical stability, particularly kinetic stability, and how this influences one's thinking about the safety of metal-ligand-based contrast agents. We discuss the mechanisms involved in MR relaxation in the context of probe design strategies. A brief description of currently available contrast agents is accompanied by an in-depth discussion that highlights promising MRI contrast agents in the development of future clinical and research applications. Our intention is to give a diverse audience an improved understanding of the factors involved in developing new types of safe and highly efficient MR contrast agents and, at the same time, provide an appreciation of the insights into physiology and disease that newer types of responsive agents can provide. © 2015 Wiley Periodicals, Inc.

  6. An evaluation of the sonoporation potential of low-boiling point phase-change ultrasound contrast agents in vitro.

    Science.gov (United States)

    Fix, Samantha M; Novell, Anthony; Yun, Yeoheung; Dayton, Paul A; Arena, Christopher B

    2017-01-01

    Phase-change ultrasound contrast agents (PCCAs) offer a solution to the inherent limitations associated with using microbubbles for sonoporation; they are characterized by prolonged circulation lifetimes, and their nanometer-scale sizes may allow for passive accumulation in solid tumors. As a first step towards the goal of extravascular cell permeabilization, we aim to characterize the sonoporation potential of a low-boiling point formulation of PCCAs in vitro. Parameters to induce acoustic droplet vaporization and subsequent microbubble cavitation were optimized in vitro using high-speed optical microscopy. Sonoporation of pancreatic cancer cells in suspension was then characterized at a range of pressures (125-600 kPa) and pulse lengths (5-50 cycles) using propidium iodide as an indicator molecule. We achieved sonoporation efficiencies ranging from 8 ± 1% to 36 ± 4% (percent of viable cells), as evidenced by flow cytometry. Increasing sonoporation efficiency trended with increasing pulse length and peak negative pressure. We conclude that PCCAs can be used to induce the sonoporation of cells in vitro, and our results warrant further investigation into the use of PCCAs as extravascular sonoporation agents in vivo.

  7. The optimal use of contrast agents at high field MRI

    International Nuclear Information System (INIS)

    Trattnig, Siegfried; Pinker, Kathia; Ba-Ssalamah, Ahmed; Noebauer-Huhmann, Iris-Melanie

    2006-01-01

    The intravenous administration of a standard dose of conventional gadolinium-based contrast agents produces higher contrast between the tumor and normal brain at 3.0 Tesla (T) than at 1.5 T, which allows reducing the dose to half of the standard one to produce similar contrast at 3.0 T compared to 1.5 T. The assessment of cumulative triple-dose 3.0 T images obtained the best results in the detection of brain metastases compared to other sequences. The contrast agent dose for dynamic susceptibility-weighted contrast-enhanced perfusion MR imaging at 3.0 T can be reduced to 0.1 mmol compared to 0.2 mmol at 1.5 T due to the increased susceptibility effects at higher magnetic field strengths. Contrast agent application makes susceptibility-weighted imaging (SWI) at 3.0 T clinically attractive, with an increase in spatial resolution within the same scan time. Whereas a double dose of conventional gadolinium-based contrast agents was optimal in SWI with respect to sensitivity and image quality, a standard dose of gadobenate dimeglumine, which has a two-fold higher T1-relaxivity in blood, produced the same effect. For MR-arthrography, optimized concentrations of gadolinium-based contrast agents are similar at 3.0 and 1.5 T. In summary, high field MRI requires the optimization of the contrast agent dose in different clinical applications. (orig.)

  8. Study of Coronary Flow Reserve with Intravenous Use of Microbubbles (Contrast Echocardiography and Adenosine: Protocol for Clinical Application in Patients Suspected of Having Coronary Heart Disease

    Directory of Open Access Journals (Sweden)

    Morcerf Fernando

    2002-01-01

    Full Text Available OBJECTIVE: To test the feasibility, safety and accuracy of the adenosine protocol in the study of myocardial perfusion with microbubbles contrast echocardiography. METHODS: 81 pts (64 male, 60+11 years were submitted to contrast echocardiography with PESDA (sonicated solution of albumin 20%-1ml, dextrose 5%-12ml and deca-fluorobutane gas-8ml to study the myocardial perfusion at rest and after bolus injection of adenosine (6 to 18mg and to coronary angiography within 1 month each other. For each patient 3 left ventricle perfusion beds were considered (total of 243 territories. 208 territories were analyzed and 35 territories were excluded. PESDA was continuously infused (1-2ml/min, titrated for best myocardial contrast. Triggered (1:1 second harmonic imaging was used. RESULTS: Coronary angiography showed 70 flow limiting (> 75% lesions and 138 no flow limiting lesions. At rest an obvious myocardium contrast enhancement was seen in at least 1 segment of a territory in all patients. After adenosine injection an unquestionable further increase in myocardial contrast was observed in 136 territories (99% related to no flow limiting lesions, lasting < 10 s, and a myocardial perfusion defect was detected in 68 territories (97% related to flow limiting lesions. It was observed only 4 false results. There were no serious complications. CONCLUSION: Myocardial perfusion study with PESDA and adenosine protocol is a practical, safe and accurate method to analyze the coronary flow reserve.

  9. Iodinated contrast agent-induced nephropathy

    International Nuclear Information System (INIS)

    Erley, C.

    2007-01-01

    Contrast-induced nephropathy (CIN) is a well-known complication of therapeutic and diagnostic procedures requiring contrast administration and accounts for 10% of acute renal failure in hospitalized patients. Although the incidence of this complication is relatively low, its consequences can be catastrophic. The development of CIN is associated with increased length of hospital stay, an increased requirement for acute dialysis, and an increased risk of death. Preexisting renal dysfunction, age, diabetes, congestive heart failure, and volume of administered contrast are all associated with a risk of developing CIN. Despite a large number of clinical trials that have evaluated prophylaxis strategies for CIN, no uniform strategies have been developed so far. The use of N-acetyl-L-cysteine (NAC) or theophylline in specific subgroups of patients has been shown to reduce dialysis requirement and mortality in patients undergoing angiographic procedures. Hemofiltration has also shown positive results. In this review we will discuss the epidemiology and the risk factors for CIN and the evidence for commonly employed prophylaxis strategies, and we will provide general recommendations with respect to CIN prevention and management. A practicable strategy to prevent CIN includes: correct identification of individuals at greatest risk, thorough evaluation of whether other diagnostic maneuvers could be employed instead (i.e., sonography), application of low-osmolar contrast media at the minimum acceptable dose, stopping potential nephrotoxic drugs (NSAID), hydration with sodium chloride 0.9% 1 ml/kg per h i.v. 12 h before and after CM application, administration of acetylcysteine 600 mg twice the day before and after (in cases of emergency investigation and high-risk patients 1200 mg i.v.), and theophylline (250-350 mg) the day before and the day after CM application (in cases of emergency investigation 5 mg/kg i.v.). (orig.) [de

  10. PBCA-based polymeric microbubbles for molecular imaging and drug delivery

    NARCIS (Netherlands)

    Koczera, Patrick; Appold, Lia; Shi, Yang; Liu, Mengjiao; Dasgupta, Anshuman; Pathak, Vertika; Ojha, Tarun; Fokong, Stanley; Wu, Zhuojun; Van Zandvoort, Marc; Iranzo, Olga; Kuehne, Alexander J C; Pich, Andrij; Kiessling, Fabian; Lammers, Twan

    2017-01-01

    Microbubbles (MB) are routinely used as contrast agents for ultrasound (US) imaging. We describe different types of targeted and drug-loaded poly(n-butyl cyanoacrylate) (PBCA) MB, and demonstrate their suitability for multiple biomedical applications, including molecular US imaging and US-mediated

  11. Image-guided, targeted and triggered drug delivery to tumors using polymer-based microbubbles.

    NARCIS (Netherlands)

    Fokong, S.; Theek, B.; Koczera, P.; Appold, L.; Resch-Genger, U.; van Zandvoort, M.; Storm, Gerrit; Kiessling, F.; Lammers, Twan Gerardus Gertudis Maria

    2012-01-01

    Abstract Microbubbles (MB) are routinely used contrast agents for functional and molecular ultrasound (US) imaging. In addition, they have been attracting more and more attention for drug delivery purposes, enabling e.g. US-mediated drug delivery across biological barriers and US-induced triggered

  12. Iron Oxide as an MRI Contrast Agent for Cell Tracking

    Science.gov (United States)

    Korchinski, Daniel J.; Taha, May; Yang, Runze; Nathoo, Nabeela; Dunn, Jeff F.

    2015-01-01

    Iron oxide contrast agents have been combined with magnetic resonance imaging for cell tracking. In this review, we discuss coating properties and provide an overview of ex vivo and in vivo labeling of different cell types, including stem cells, red blood cells, and monocytes/macrophages. Furthermore, we provide examples of applications of cell tracking with iron contrast agents in stroke, multiple sclerosis, cancer, arteriovenous malformations, and aortic and cerebral aneurysms. Attempts at quantifying iron oxide concentrations and other vascular properties are examined. We advise on designing studies using iron contrast agents including methods for validation. PMID:26483609

  13. The interaction of MRI contrast agents with phospholipids

    International Nuclear Information System (INIS)

    Jendrasiak, Gordon L.; Smith, Ralph L.; Ribeiro, Anthony A.

    2000-01-01

    The molecular interactions of three clinically used MRI contrast agents with lipid vesicles, consisting of egg phosphatidylcholine (EPC), have been studied using high-field NMR techniques. At a molar ratio of one contrast agent molecule to five phospholipid molecules, a significant increase in the proton resonance line width occurred for certain lipid head group moieties. A large decrease in the T 1 relaxation times for the head group moieties was also observed. These two effects occurred regardless of the ionic status and the chelate structure of the three contrast agents. The structure of the contrast agents did, however, affect the magnitude of the two NMR parameter changes. These NMR effects also differed in magnitude amongst the various head group entities. The NMR effects were greatest for the head group moieties at or near the vesicle-water interface. The results are discussed in terms of the structure of the phospholipid-water interface. Since the use of contrast agents has become routine in clinical MRI, our results are of importance in terms of the interaction of the agents with physiological surfaces, many of which contain phospholipids. The understanding of such interactions should be of value not only for improved diagnostics, but also in the development of new contrast agents. (author)

  14. Harmonic US imaging of vesicoureteric reflux in children: usefulness of a second generation US contrast agent.

    Science.gov (United States)

    Ascenti, Giorgio; Zimbaro, Giovanni; Mazziotti, Silvio; Chimenz, Roberto; Fede, Carmelo; Visalli, Carmela; Scribano, Emanuele

    2004-06-01

    Contrast-enhanced voiding urosonography (VUS) is largely accepted both for the diagnosis and follow-up of vesicoureteric reflux (VUR) in children. To evaluate the usefulness of contrast-enhanced second-harmonic VUS in the diagnosis and grading of VUR, using a second-generation contrast agent. Eighty consecutive children were prospectively studied with contrast-enhanced second-harmonic VUS. All children received a second-generation contrast medium, constituted by phospholipid-stabilized microbubbles of sulphur-hexafluoride (SonoVue, Bracco, Milan, Italy). US monitoring of the bladder, of the retrovesical space and of the kidneys was performed using, alternatively, both tissue-harmonic and contrast-harmonic modes. In those young boys where VUR was depicted at VUS, examination was completed with transperineal, sagittal urethral exploration during micturition. VUR was graded in five steps and diagnoses were compared with voiding cystourethrography (VCUG). VUR was diagnosed in 52 reno-ureteral units with VUS. In 49 of these reno-ureteral units, VCUG confirmed the presence of VUR. In comparison to VUS, sensitivity and negative predictive value of VCUG were inferior. The grade of VUR detected at VUS was higher than that detected at VCUG in three units. In no case was the grade of VUR detected at VCUG higher than the one detected at VUS. The differences between VUS and VCUG in grading VUR were statistically significant (p=0.02). Imaging of the normal posterior urethra was skilfully demonstrated with US in 15 young boys with VUR. No statistically significant differences were found between tissue-harmonic and contrast-harmonic mode (p=0.102). Contrast-enhanced second-harmonic VUS is a sensitive and easy technique for the evaluation of VUR. A second-generation US contrast medium such as SonoVue, if available, should be the first choice as the dose required for one examination is much lower and consequently significant reduction of contrast agent cost is possible. Copyright

  15. Fundamental studies of oral contrast agents for MR. Comparison of manganese agent and iron agent

    International Nuclear Information System (INIS)

    Fujita, Osamu; Hiraishi, Kumiko; Suginobu, Yoshito; Takeuchi, Masayasu; Narabayashi, Isamu

    1996-01-01

    We investigated and compared signal intensity and the effect of imaging the upper abdomen with blueberry juice (B.J.), a Mn agent utilizing the properties of paramagnetic metals, and FerriSeltz (F.S.), an iron agent. Since the relaxation effect was much stronger with B.J. than with F.S., the signal intensity required of a peroral contrast agent was able to be obtained at a much lower concentration of B.J. In imaging the upper abdomen, B.J. had a positive effect on imaging in T1-weighted images, and a negative effect in T2-weighted images. F.S. had a positive imaging effect in both, and because it showed extremely high signals in T2-weighted images, motion artifact arose. (author)

  16. A model for ultrasound contrast agent in a phantom vessel

    KAUST Repository

    Qamar, Adnan; Samtaney, Ravi

    2014-01-01

    A theoretical framework to model the dynamics of Ultrasound Contrast Agent (UCA) inside a phantom vessel is presented. The model is derived from the reduced Navier-Stokes equation and is coupled with the evolving flow field solution inside

  17. Quinone-fused porphyrins as contrast agents for photoacoustic imaging

    KAUST Repository

    Banala, Srinivas; Fokong, Stanley; Brand, Christian; Andreou, Chrysafis; Krä utler, Bernhard; Rueping, Magnus; Kiessling, Fabian

    2017-01-01

    Photoacoustic (PA) imaging is an emerging non-invasive diagnostic modality with many potential clinical applications in oncology, rheumatology and the cardiovascular field. For this purpose, there is a high demand for exogenous contrast agents

  18. MRI contrast agent concentration and tumor interstitial fluid pressure.

    Science.gov (United States)

    Liu, L J; Schlesinger, M

    2016-10-07

    The present work describes the relationship between tumor interstitial fluid pressure (TIFP) and the concentration of contrast agent for dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI). We predict the spatial distribution of TIFP based on that of contrast agent concentration. We also discuss the cases for estimating tumor interstitial volume fraction (void fraction or porosity of porous medium), ve, and contrast volume transfer constant, K(trans), by measuring the ratio of contrast agent concentration in tissue to that in plasma. A linear fluid velocity distribution may reflect a quadratic function of TIFP distribution and lead to a practical method for TIFP estimation. To calculate TIFP, the parameters or variables should preferably be measured along the direction of the linear fluid velocity (this is in the same direction as the gray value distribution of the image, which is also linear). This method may simplify the calculation for estimating TIFP. Crown Copyright © 2016. Published by Elsevier Ltd. All rights reserved.

  19. The clinical use of contrast agents in magnetic resonance imaging

    International Nuclear Information System (INIS)

    Bydder, G.M.

    1987-01-01

    Interest in the use of external agents to increase tissue contrasts has come from many sources dating back to the earliest work in NMR, to animal studies and to the widespread use of contrast agents in conventional radiological practice. The first clinical magnetic resonance images were published in 1980 and in the following year a brief account of the use of the paramagnetic agents in human volunteers was established. It was apparent relatively early in the development of magnetic resonance imaging (MRI) that a high level of soft tissue contrast was available de novo and the need for externally administered agents might therefore be small. This observation was tempered by the fact that separation of tumour from oedema was frequently better with contrast enhanced CT X-ray than with unenhanced MRI and that of a contrast agent might therefore be needed for MRI. At the end of 1983 the first parenteral agent gadoliminum diethylene triamine pentaacetic acid (Gd-DTPA) was used in volunteers and clinical studies began in 1984. At the present time only molecular O/sub 2/, oral iron compounds and Gd-DTPA are in clinical use although there are a number of other agents which have been used in animals and some of these may become available for clinical use in the foreseeable future

  20. Modified natural nanoparticles as contrast agents for medical imaging

    NARCIS (Netherlands)

    Cormode, David P.; Jarzyna, Peter A.; Mulder, Willem J. M.; Fayad, Zahi A.

    2010-01-01

    The development of novel and effective contrast agents is one of the drivers of the ongoing improvement in medical imaging. Many of the new agents reported are nanoparticle-based. There are a variety of natural nanoparticles known, e.g. lipoproteins, viruses or ferritin. Natural nanoparticles have

  1. Multiwalled carbon nanotube hybrids as MRI contrast agents

    Directory of Open Access Journals (Sweden)

    Nikodem Kuźnik

    2016-07-01

    Full Text Available Magnetic resonance imaging (MRI is one of the most commonly used tomography techniques in medical diagnosis due to the non-invasive character, the high spatial resolution and the possibility of soft tissue imaging. Contrast agents, such as gadolinium complexes and superparamagnetic iron oxides, are administered to spotlight certain organs and their pathologies. Many new models have been proposed that reduce side effects and required doses of these already clinically approved contrast agents. These new candidates often possess additional functionalities, e.g., the possibility of bioactivation upon action of particular stimuli, thus serving as smart molecular probes, or the coupling with therapeutic agents and therefore combining both a diagnostic and therapeutic role. Nanomaterials have been found to be an excellent scaffold for contrast agents, among which carbon nanotubes offer vast possibilities. The morphology of multiwalled carbon nanotubes (MWCNTs, their magnetic and electronic properties, the possibility of different functionalization and the potential to penetrate cell membranes result in a unique and very attractive candidate for a new MRI contrast agent. In this review we describe the different issues connected with MWCNT hybrids designed for MRI contrast agents, i.e., their synthesis and magnetic and dispersion properties, as well as both in vitro and in vivo behavior, which is important for diagnostic purposes. An introduction to MRI contrast agent theory is elaborated here in order to point to the specific expectations regarding nanomaterials. Finally, we propose a promising, general model of MWCNTs as MRI contrast agent candidates based on the studies presented here and supported by appropriate theories.

  2. Field strength and dose dependence of contrast enhancement by gadolinium-based MR contrast agents

    International Nuclear Information System (INIS)

    Rinck, P.A.; Muller, R.N.

    1999-01-01

    The relaxivities r 1 and r 2 of magnetic resonance contrast agents and the T 1 relaxation time values of tissues are strongly field dependent. We present quantitative data and simulations of different gadolinium-based extracellular fluid contrast agents and the modulation of their contrast enhancement by the magnetic field to be able to answer the following questions: How are the dose and field dependences of their contrast enhancement? Is there an interrelationship between dose and field dependence? Should one increase or decrease doses at specific fields? Nuclear magnetic relaxation dispersion data were acquired for the following contrast agents: gadopentetate dimeglumine, gadoterate meglumine, gadodiamide injection, and gadoteridol injection, as well as for several normal and pathological human tissue samples. The magnetic field range stretched from 0.0002 to 4.7 T, including the entire clinical imaging range. The data acquired were then fitted with the appropriate theoretical models. The combination of the diamagnetic relaxation rates (R 1 = 1/T 1 and R 2 = 1/T 2 ) of tissues with the respective paramagnetic contributions of the contrast agents allowed the prediction of image contrast at any magnetic field. The results revealed a nearly identical field and dose-dependent increase of contrast enhancement induced by these contrast agents within a certain dose range. The target tissue concentration (TTC) was an important though nonlinear factor for enhancement. The currently recommended dose of 0.1 mmol/kg body weight seems to be a compromise close to the lower limits of diagnostically sufficient contrast enhancement for clinical imaging at all field strengths. At low field contrast enhancement might be insufficient. Adjustment of dose or concentration, or a new class of contrast agents with optimized relaxivity, would be a valuable contribution to a better diagnostic yield of contrast enhancement at all fields. (orig.)

  3. Contrast agent enhanced pQCT of articular cartilage

    Energy Technology Data Exchange (ETDEWEB)

    Kallioniemi, A S [Department of Physics, University of Kuopio, POB 1627, 70211 Kuopio (Finland); Jurvelin, J S [Department of Physics, University of Kuopio, POB 1627, 70211 Kuopio (Finland); Nieminen, M T [Department of Diagnostic Radiology, POB 50, 90029 OYS, Oulu University Hospital, Oulu (Finland); Lammi, M J [Department of Anatomy, Institute of Biomedicine, University of Kuopio, POB 1627, 70211 Kuopio (Finland); Toeyraes, J [Department of Physics, University of Kuopio, POB 1627, 70211 Kuopio (Finland)

    2007-02-21

    The delayed gadolinium enhanced MRI of cartilage (dGEMRIC) technique is the only non-invasive means to estimate proteoglycan (PG) content in articular cartilage. In dGEMRIC, the anionic paramagnetic contrast agent gadopentetate distributes in inverse relation to negatively charged PGs, leading to a linear relation between T{sub 1,Gd} and spatial PG content in tissue. In the present study, for the first time, contrast agent enhanced peripheral quantitative computed tomography (pQCT) was applied, analogously to dGEMRIC, for the quantitative detection of spatial PG content in cartilage. The suitability of two anionic radiographic contrast agents, gadopentetate and ioxaglate, to detect enzymatically induced PG depletion in articular cartilage was investigated. First, the interrelationships of x-ray absorption, as measured with pQCT, and the contrast agent solution concentration were investigated. Optimal contrast agent concentrations for the following experiments were selected. Second, diffusion rates for both contrast agents were investigated in intact (n = 3) and trypsin-degraded (n 3) bovine patellar cartilage. The contrast agent concentration of the cartilaginous layer was measured prior to and 2-27 h after immersion. Optimal immersion time for the further experiments was selected. Third, the suitability of gadopentetate and ioxaglate enhanced pQCT to detect the enzymatically induced specific PG depletion was investigated by determining the contrast agent concentrations and uronic acid and water contents in digested and intact osteochondral samples (n = 16). After trypsin-induced PG loss (-70%, p < 0.05) the penetration of gadopentetate and ioxaglate increased (p < 0.05) by 34% and 48%, respectively. Gadopentetate and ioxaglate concentrations both showed strong correlation (r = -0.95, r -0.94, p < 0.01, respectively) with the uronic acid content. To conclude, contrast agent enhanced pQCT provides a technique to quantify PG content in normal and experimentally

  4. Contrast agent enhanced pQCT of articular cartilage

    Science.gov (United States)

    Kallioniemi, A. S.; Jurvelin, J. S.; Nieminen, M. T.; Lammi, M. J.; Töyräs, J.

    2007-02-01

    The delayed gadolinium enhanced MRI of cartilage (dGEMRIC) technique is the only non-invasive means to estimate proteoglycan (PG) content in articular cartilage. In dGEMRIC, the anionic paramagnetic contrast agent gadopentetate distributes in inverse relation to negatively charged PGs, leading to a linear relation between T1,Gd and spatial PG content in tissue. In the present study, for the first time, contrast agent enhanced peripheral quantitative computed tomography (pQCT) was applied, analogously to dGEMRIC, for the quantitative detection of spatial PG content in cartilage. The suitability of two anionic radiographic contrast agents, gadopentetate and ioxaglate, to detect enzymatically induced PG depletion in articular cartilage was investigated. First, the interrelationships of x-ray absorption, as measured with pQCT, and the contrast agent solution concentration were investigated. Optimal contrast agent concentrations for the following experiments were selected. Second, diffusion rates for both contrast agents were investigated in intact (n = 3) and trypsin-degraded (n = 3) bovine patellar cartilage. The contrast agent concentration of the cartilaginous layer was measured prior to and 2-27 h after immersion. Optimal immersion time for the further experiments was selected. Third, the suitability of gadopentetate and ioxaglate enhanced pQCT to detect the enzymatically induced specific PG depletion was investigated by determining the contrast agent concentrations and uronic acid and water contents in digested and intact osteochondral samples (n = 16). After trypsin-induced PG loss (-70%, p < 0.05) the penetration of gadopentetate and ioxaglate increased (p < 0.05) by 34% and 48%, respectively. Gadopentetate and ioxaglate concentrations both showed strong correlation (r = -0.95, r = -0.94, p < 0.01, respectively) with the uronic acid content. To conclude, contrast agent enhanced pQCT provides a technique to quantify PG content in normal and experimentally

  5. Contrast agent enhanced pQCT of articular cartilage

    International Nuclear Information System (INIS)

    Kallioniemi, A S; Jurvelin, J S; Nieminen, M T; Lammi, M J; Toeyraes, J

    2007-01-01

    The delayed gadolinium enhanced MRI of cartilage (dGEMRIC) technique is the only non-invasive means to estimate proteoglycan (PG) content in articular cartilage. In dGEMRIC, the anionic paramagnetic contrast agent gadopentetate distributes in inverse relation to negatively charged PGs, leading to a linear relation between T 1,Gd and spatial PG content in tissue. In the present study, for the first time, contrast agent enhanced peripheral quantitative computed tomography (pQCT) was applied, analogously to dGEMRIC, for the quantitative detection of spatial PG content in cartilage. The suitability of two anionic radiographic contrast agents, gadopentetate and ioxaglate, to detect enzymatically induced PG depletion in articular cartilage was investigated. First, the interrelationships of x-ray absorption, as measured with pQCT, and the contrast agent solution concentration were investigated. Optimal contrast agent concentrations for the following experiments were selected. Second, diffusion rates for both contrast agents were investigated in intact (n = 3) and trypsin-degraded (n 3) bovine patellar cartilage. The contrast agent concentration of the cartilaginous layer was measured prior to and 2-27 h after immersion. Optimal immersion time for the further experiments was selected. Third, the suitability of gadopentetate and ioxaglate enhanced pQCT to detect the enzymatically induced specific PG depletion was investigated by determining the contrast agent concentrations and uronic acid and water contents in digested and intact osteochondral samples (n = 16). After trypsin-induced PG loss (-70%, p < 0.05) the penetration of gadopentetate and ioxaglate increased (p < 0.05) by 34% and 48%, respectively. Gadopentetate and ioxaglate concentrations both showed strong correlation (r = -0.95, r -0.94, p < 0.01, respectively) with the uronic acid content. To conclude, contrast agent enhanced pQCT provides a technique to quantify PG content in normal and experimentally degraded

  6. Biodistribution, kinetics, and biological fate of SPION microbubbles in the rat

    Directory of Open Access Journals (Sweden)

    Barrefelt A

    2013-08-01

    Full Text Available Åsa Barrefelt,1,2,* Maryam Saghafian,2,* Raoul Kuiper,3 Fei Ye,4 Gabriella Egri,5 Moritz Klickermann,5 Torkel B Brismar,1 Peter Aspelin,1 Mamoun Muhammed,4 Lars Dähne,5 Moustapha Hassan2,6 1Department of Clinical Science, Intervention and Technology, Division of Medical Imaging and Technology, Karolinska Institutet, and Department of Radiology, Karolinska University Hospital-Huddinge, Stockholm, Sweden; 2Experimental Cancer Medicine, Department of Laboratory Medicine, Karolinska Institutet, Stockholm, Sweden; 3Karolinska Institute Core Facility for Morphologic Phenotype Analysis, Clinical Research Center, Karolinska University Hospital-Huddinge, Stockholm, Sweden; 4Division of Functional Materials, Department of Materials and Nano Physics, Royal Institute of Technology, Stockholm, Sweden; 5Surflay Nanotec GmbH, Berlin, Germany; 6Clinical Research Center, Karolinska University Hospital-Huddinge, Stockholm, Sweden *These authors contributed equally to this work Background: In the present investigation, we studied the kinetics and biodistribution of a contrast agent consisting of poly(vinyl alcohol (PVA microbubbles containing superparamagnetic iron oxide (SPION trapped between the PVA layers (SPION microbubbles. Methods: The biological fate of SPION microbubbles was determined in Sprague-Dawley rats after intravenous administration. Biodistribution and elimination of the microbubbles were studied in rats using magnetic resonance imaging for a period of 6 weeks. The rats were sacrificed and perfusion-fixated at different time points. The magnetic resonance imaging results obtained were compared with histopathologic findings in different organs. Results: SPION microbubbles could be detected in the liver using magnetic resonance imaging as early as 10 minutes post injection. The maximum signal was detected between 24 hours and one week post injection. Histopathology showed the presence of clustered SPION microbubbles predominantly in the lungs from

  7. Introduction to the ultrasound targeted microbubble destruction technique.

    Science.gov (United States)

    Walton, Chad B; Anderson, Cynthia D; Boulay, Rachel; Shohet, Ralph V

    2011-06-12

    In UTMD, bioactive molecules, such as negatively charged plasmid DNA vectors encoding a gene of interest, are added to the cationic shells of lipid microbubble contrast agents. In mice these vector-carrying microbubbles can be administered intravenously or directly to the left ventricle of the heart. In larger animals they can also be infused through an intracoronary catheter. The subsequent delivery from the circulation to a target organ occurs by acoustic cavitation at a resonant frequency of the microbubbles. It seems likely that the mechanical energy generated by the microbubble destruction results in transient pore formation in or between the endothelial cells of the microvasculature of the targeted region. As a result of this sonoporation effect, the transfection efficiency into and across the endothelial cells is enhanced, and transgene-encoding vectors are deposited into the surrounding tissue. Plasmid DNA remaining in the circulation is rapidly degraded by nucleases in the blood, which further reduces the likelihood of delivery to non-sonicated tissues and leads to highly specific target-organ transfection.

  8. Cationic Contrast Agent Diffusion Differs Between Cartilage and Meniscus.

    Science.gov (United States)

    Honkanen, Juuso T J; Turunen, Mikael J; Freedman, Jonathan D; Saarakkala, Simo; Grinstaff, Mark W; Ylärinne, Janne H; Jurvelin, Jukka S; Töyräs, Juha

    2016-10-01

    Contrast enhanced computed tomography (CECT) is a non-destructive imaging technique used for the assessment of composition and structure of articular cartilage and meniscus. Due to structural and compositional differences between these tissues, diffusion and distribution of contrast agents may differ in cartilage and meniscus. The aim of this study is to determine the diffusion kinematics of a novel iodine based cationic contrast agent (CA(2+)) in cartilage and meniscus. Cylindrical cartilage and meniscus samples (d = 6 mm, h ≈ 2 mm) were harvested from healthy bovine knee joints (n = 10), immersed in isotonic cationic contrast agent (20 mgI/mL), and imaged using a micro-CT scanner at 26 time points up to 48 h. Subsequently, normalized X-ray attenuation and contrast agent diffusion flux, as well as water, collagen and proteoglycan (PG) contents in the tissues were determined. The contrast agent distributions within cartilage and meniscus were different. In addition, the normalized attenuation and diffusion flux were higher (p < 0.05) in cartilage. Based on these results, diffusion kinematics vary between cartilage and meniscus. These tissue specific variations can affect the interpretation of CECT images and should be considered when cartilage and meniscus are assessed simultaneously.

  9. Rare earth contrast agents in hepatic computed tomography

    International Nuclear Information System (INIS)

    Seltzer, S.E.

    1981-01-01

    Materials with atomic numbers ranging from the upper 50's to the lower 70's proved to have the highest computed tomography (CT) numbers when scanned at 120 kVp. Therefore, to produce particulate contrast agents possessing maximum radiopacity, suspensions of cerium oxide, gadolinium, and dysprosium oxides as well as silver iodide colloid were prepared. All 4 agents were selectively concentrated in the reticulo-endothelial system. The agents produced greater and longer opacification of the normal liver and larger liver-to-tumor differences in rabbits with hepatic tumors than did equivalent amounts of standard intravenous iodinated agents. Lesions as small as 5 mm were visible with CT. These materials have favorable characteristics as hepatic contrast agents, but their toxicity (LD 50 in mice = 5.4 g/kg for Ce) and long-term retention may limit clinical use. (Auth.)

  10. Targeting cancer chemotherapeutic agents by use of lipiodol contrast medium

    International Nuclear Information System (INIS)

    Konno, T.

    1990-01-01

    Arterially administered Lipiodol Ultrafluid contrast medium selectively remained in various malignant solid tumors because of the difference in time required for the removal of Lipiodol contrast medium from normal capillaries and tumor neovasculature. Although blood flow was maintained in the tumor, even immediately after injection Lipiodol contrast medium remained in the neovasculature of the tumor. To target anti-cancer agents to tumors by using Lipiodol contrast medium as a carrier, the characteristics of the agents were examined. Anti-cancer agents had to be soluble in Lipiodol, be stable in it, and separate gradually from it so that the anti-cancer agents would selectively remain in the tumor. These conditions were found to be necessary on the basis of the measurement of radioactivity in VX2 tumors implanted in the liver of 16 rabbits that received arterial injections of 14C-labeled doxorubicin. Antitumor activities and side effects of arterial injections of two types of anti-cancer agents were compared in 76 rabbits with VX2 tumors. Oily anti-cancer agents that had characteristics essential for targeting were compared with simple mixtures of anti-cancer agents with Lipiodol contrast medium that did not have these essential characteristics. Groups of rabbits that received oily anti-cancer agents responded significantly better than groups that received simple mixtures, and side effects were observed more frequently in the groups that received the simple mixtures. These results suggest that targeting of the anti-cancer agent to the tumor is important for treatment of solid malignant tumors

  11. Analytical interference by contrast agents in biochemical assays

    DEFF Research Database (Denmark)

    Otnes, Sigrid; Fogh-Andersen, Niels; Rømsing, Janne

    2017-01-01

    Objective. To provide a clinically relevant overview of the analytical interference by contrast agents (CA) in laboratory blood test measurements. Materials and Methods. The effects of five CAs, gadobutrol, gadoterate meglumine, gadoxetate disodium, iodixanol, and iomeprol, were studied on the 29...... most frequently performed biochemical assays. One-day-old plasma, serum, and whole blood were spiked with doses of each agent such that the gadolinium agents and the iodine agents reached concentrations of 0.5mMand 12mg iodine/mL, respectively. Subsequently, 12 assays were reexamined using 1/2 and 1...

  12. Self-demodulation effect on subharmonic response of ultrasound contrast agent

    Science.gov (United States)

    Daeichin, V.; Faez, T.; Needles, A.; Renaud, G.; Bosch, J. G.; van der Steen, A. F. W.; de Jong, N.

    2012-03-01

    In this work the use of the self-demodulation (S-D) signal as a mean of microbubble excitation at the subharmonic (SH) frequency to enhance the SH emission of ultrasound contrast agent (UCA) is studied. SH emission from the UCA is of interest since it is produced only by the UCA and is free of the artifacts produced in harmonic imaging modes. The S-D wave is a low-frequency signal produced by nonlinear propagation of an ultrasound wave in the medium. Single element transducer experiments and numerical simulations were conducted at 10 MHz to study the effect of the S-D signal on the SH response of the UCA by modifying the envelope of the excitation bursts. For 6 and 20 transmitted cycles, the SH response is increased up to 25 dB and 22 dB because of the S-D stimulation for a burst with a rectangular envelope compared with a Gaussian envelope burst. Such optimized excitations were used in an array-based micro-ultrasound system (Vevo 2100, VisualSonics Inc., Toronto, ON, Canada) at 18 MHz for in vitro validation of SH imaging. This study suggests that a suitable design of the envelope of the transmit excitation to generate a S-D signal at the SH frequency can enhance the SH emission of UCA and real-time SH imaging is feasible with shorter transmit burst (6- cycle) and low acoustic pressure (~150 KPa) at high frequencies (>15 MHz).

  13. Streaming flow from ultrasound contrast agents by acoustic waves in a blood vessel model.

    Science.gov (United States)

    Cho, Eunjin; Chung, Sang Kug; Rhee, Kyehan

    2015-09-01

    To elucidate the effects of streaming flow on ultrasound contrast agent (UCA)-assisted drug delivery, streaming velocity fields from sonicated UCA microbubbles were measured using particle image velocimetry (PIV) in a blood vessel model. At the beginning of ultrasound sonication, the UCA bubbles formed clusters and translated in the direction of the ultrasound field. Bubble cluster formation and translation were faster with 2.25MHz sonication, a frequency close to the resonance frequency of the UCA. Translation of bubble clusters induced streaming jet flow that impinged on the vessel wall, forming symmetric vortices. The maximum streaming velocity was about 60mm/s at 2.25MHz and decreased to 15mm/s at 1.0MHz for the same acoustic pressure amplitude. The effect of the ultrasound frequency on wall shear stress was more noticeable. Maximum wall shear stress decreased from 0.84 to 0.1Pa as the ultrasound frequency decreased from 2.25 to 1.0MHz. The maximum spatial gradient of the wall shear stress also decreased from 1.0 to 0.1Pa/mm. This study showed that streaming flow was induced by bubble cluster formation and translation and was stronger upon sonication by an acoustic wave with a frequency near the UCA resonance frequency. Therefore, the secondary radiant force, which is much stronger at the resonance frequency, should play an important role in UCA-assisted drug delivery. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Detection of an occult hepatocellular carcinoma using ultrasound with liver-specific microbubbles

    International Nuclear Information System (INIS)

    Harvey, Christopher J.; Lim, Adrian K.P.; Blomley, Martin J.K.; Cosgrove, David O.; Taylor-Robinson, Simon D.; Gedroyc, Wladyslaw M.W.

    2002-01-01

    The radiological surveillance of cirrhosis to detect the development of hepatocellular carcinoma (HCC) is problematic because no highly sensitive and specific imaging investigation is available. Ultrasound is typically the first modality used but is less accurate than other imaging modalities. We report the first case of a patient with cirrhosis in whom US imaging with liver-specific microbubbles detected an HCC prior to its detection by MR. The use of liver-specific microbubble US contrast agents is an exciting development in the detection of HCC in chronic liver disease and may help to rectify some of the shortcomings of US. (orig.)

  15. Spectral triangulation molecular contrast optical coherence tomography with indocyanine green as the contrast agent

    OpenAIRE

    Yang, Changhuei; McGuckin, Laura E. L.; Simon, John D.; Choma, Michael A.; Applegate, Brian E.; Izatt, Joseph A.

    2004-01-01

    We report a new molecular contrast optical coherence tomography (MCOCT) implementation that profiles the contrast agent distribution in a sample by measuring the agent's spectral differential absorption. The method, spectra triangulation MCOCT, can effectively suppress contributions from spectrally dependent scatterings from the sample without a priori knowledge of the scattering properties. We demonstrate molecular imaging with this new MCOCT modality by mapping the distribution of indocyani...

  16. Evaluation of potential gastrointestinal contrast agents for echoplanar MR imaging

    International Nuclear Information System (INIS)

    Reimer, P.; Schmitt, F.; Ladebeck, R.; Graessner, J.; Schaffer, B.

    1993-01-01

    The purpose of this study was to investigate approved aqueous gastrointestinal contrast agents for use in abdominal EPI. Conventional and echoplanar MR imaging experiments were performed with 1.0 Tesla whole body systems. Phantom measurements of Gastrografin, barium sulfate suspension, oral gadopentetate dimeglumine, water, and saline were performed. Signal intensity (SI) of aqueous oral barium sulfate and iodine based CT contrast agents was lower on conventional spin-echo (SE), Flash, and Turbo-Flush images than on EP images. The contrast agents exhibited higher SI on T2-weighted SE PE images and TI-time dependence on inversion recovery EP-images. The barium sulfate suspension was administered in volunteers to obtain information about bowel lumen enhancement and susceptibility artifacts. Oral administration of the aqueous barium sulfate suspension increased bowel lumen signal and reduced susceptibility artifacts. (orig.)

  17. Contrast enhancement by lipid-based MRI contrast agents in mouse atherosclerotic plaques; a longitudinal study

    NARCIS (Netherlands)

    den Adel, Brigit; van der Graaf, Linda M.; Que, Ivo; Strijkers, Gustav J.; Löwik, Clemens W.; Poelmann, Robert E.; van der Weerd, Louise

    2013-01-01

    The use of contrast-enhanced MRI to enable in vivo specific characterization of atherosclerotic plaques is increasing. In this study the intrinsic ability of two differently sized gadolinium-based contrast agents to enhance atherosclerotic plaques in ApoE(-/-) mice was evaluated with MRI. We

  18. Exogenous contrast agents for thermoacoustic imaging: An investigation into the underlying sources of contrast

    International Nuclear Information System (INIS)

    Ogunlade, Olumide; Beard, Paul

    2015-01-01

    Purpose: Thermoacoustic imaging at microwave excitation frequencies is limited by the low differential contrast exhibited by high water content tissues. To overcome this, exogenous thermoacoustic contrast agents based on gadolinium compounds, iron oxide, and single wall carbon nanotubes have previously been suggested and investigated. However, these previous studies did not fully characterize the electric, magnetic, and thermodynamic properties of these agents thus precluding identification of the underlying sources of contrast. To address this, measurements of the complex permittivity, complex permeability, DC conductivity, and Grüneisen parameter have been made. These measurements allowed the origins of the contrast provided by each substance to be identified. Methods: The electric and magnetic properties of the contrast agents were characterized at 3 GHz using two rectangular waveguide cavities. The DC conductivity was measured separately using a conductivity meter. Thermoacoustic signals were then acquired and compared to those generated in water. Finally, 3D electromagnetic simulations were used to decouple the different contributions to the absorbed power density. Results: It was found that the gadolinium compounds provided appreciable electric contrast but not originating from the gadolinium itself. The contrast was either due to dissociation of the gadolinium salt which increased ionic conductivity or its nondissociated polar fraction which increased dielectric polarization loss or a combination of both. In addition, very high concentrations were required to achieve appreciable contrast, to the extent that the Grüneisen parameter increased significantly and became a source of contrast. Iron oxide particles were found to produce low but measurable dielectric contrast due to dielectric polarization loss, but this is attributed to the coating of the particles not the iron oxide. Single wall carbon nanotubes did not provide measurable contrast of any type

  19. Exogenous contrast agents for thermoacoustic imaging: An investigation into the underlying sources of contrast

    Energy Technology Data Exchange (ETDEWEB)

    Ogunlade, Olumide, E-mail: o.ogunlade@ucl.ac.uk; Beard, Paul [Department of Medical Physics and Biomedical Engineering, University College London, London WC1E 6BT (United Kingdom)

    2015-01-15

    Purpose: Thermoacoustic imaging at microwave excitation frequencies is limited by the low differential contrast exhibited by high water content tissues. To overcome this, exogenous thermoacoustic contrast agents based on gadolinium compounds, iron oxide, and single wall carbon nanotubes have previously been suggested and investigated. However, these previous studies did not fully characterize the electric, magnetic, and thermodynamic properties of these agents thus precluding identification of the underlying sources of contrast. To address this, measurements of the complex permittivity, complex permeability, DC conductivity, and Grüneisen parameter have been made. These measurements allowed the origins of the contrast provided by each substance to be identified. Methods: The electric and magnetic properties of the contrast agents were characterized at 3 GHz using two rectangular waveguide cavities. The DC conductivity was measured separately using a conductivity meter. Thermoacoustic signals were then acquired and compared to those generated in water. Finally, 3D electromagnetic simulations were used to decouple the different contributions to the absorbed power density. Results: It was found that the gadolinium compounds provided appreciable electric contrast but not originating from the gadolinium itself. The contrast was either due to dissociation of the gadolinium salt which increased ionic conductivity or its nondissociated polar fraction which increased dielectric polarization loss or a combination of both. In addition, very high concentrations were required to achieve appreciable contrast, to the extent that the Grüneisen parameter increased significantly and became a source of contrast. Iron oxide particles were found to produce low but measurable dielectric contrast due to dielectric polarization loss, but this is attributed to the coating of the particles not the iron oxide. Single wall carbon nanotubes did not provide measurable contrast of any type

  20. Influence of radiographic contrast agents on quantitative coronary angiography

    International Nuclear Information System (INIS)

    Jost, Stefan; Hausmann, Dirk; Lippolt, Peter; Gerhardt, Uwe; Lichtlen, Paul R.

    1997-01-01

    Purpose. Quantitative angiographic studies on the vasomotility of epicardial coronary arteries are gaining increasing relevance. We investigated whether radiographic contrast agents might influence coronary vasomotor tone and thereby the results of such studies. Methods. Coronary angiograms were taken in 12 patients with coronary artery disease at intervals of 5, 3, 2, and 1 min with the low-osmolar, nonionic contrast agent iopamidol 300, and were repeated at identical intervals with the high-osmolar, ionic agent diatrizoate 76%. Results. Quantitative cine film analysis demonstrated no significant diameter changes in angiographically normal and stenotic coronary arteries with iopamidol. With diatrizoate, however, normal segments were dilated 2%±2% (p<0.01) after 2 min and 10%±3% after the 1 min interval (p<0.001). Stenoses showed no uniform responses to diatrizoate. Conclusion. Low-osmolar, nonionic contrast agents should be preferred for quantitative angiographic studies on epicardial coronary vasomotility. When using ionic contrast agents, injection intervals of at least 3 min are required

  1. Gd-HOPO Based High Relaxivity MRI Contrast Agents

    Energy Technology Data Exchange (ETDEWEB)

    Datta, Ankona; Raymond, Kenneth

    2008-11-06

    Tris-bidentate HOPO-based ligands developed in our laboratory were designed to complement the coordination preferences of Gd{sup 3+}, especially its oxophilicity. The HOPO ligands provide a hexadentate coordination environment for Gd{sup 3+} in which all he donor atoms are oxygen. Because Gd{sup 3+} favors eight or nine coordination, this design provides two to three open sites for inner-sphere water molecules. These water molecules rapidly exchange with bulk solution, hence affecting the relaxation rates of bulk water olecules. The parameters affecting the efficiency of these contrast agents have been tuned to improve contrast while still maintaining a high thermodynamic stability for Gd{sup 3+} binding. The Gd- HOPO-based contrast agents surpass current commercially available agents ecause of a higher number of inner-sphere water molecules, rapid exchange of inner-sphere water molecules via an associative mechanism, and a long electronic relaxation time. The contrast enhancement provided by these agents is at least twice that of commercial contrast gents, which are based on polyaminocarboxylate ligands.

  2. Safety of ultrasound contrast agents in stress echocardiography.

    Science.gov (United States)

    Gabriel, Ruvin S; Smyth, Yvonne M; Menon, Venu; Klein, Allan L; Grimm, Richard A; Thomas, James D; Sabik, Ellen Mayer

    2008-11-01

    Definity and Optison are perflutren-based ultrasound contrast agents used in echocardiography. United States Food and Drug Administration warnings regarding serious cardiopulmonary reactions and death after Definity administration highlighted the limited safety data in patients who undergo contrast stress echocardiography. From 1998 and 2007, 2,022 patients underwent dobutamine stress echocardiography and 2,764 underwent exercise stress echocardiography with contrast at the Cleveland Clinic. The echocardiographic database, patient records, and the Social Security Death Index were reviewed for the timing and cause of death, severe adverse events, arrhythmias, and symptoms. Complication rates for contrast dobutamine stress echocardiography and exercise stress echocardiography were compared with those in a control group of 5,012 patients matched for test year and type who did not receive contrast. Ninety-five percent of studies were performed in outpatients. There were no differences in the rates of severe adverse events (0.19% vs 0.17%, p = 0.7), death within 24 hours (0% vs 0.04%, p = 0.1), cardiac arrest (0.04% vs 0.04%, p = 0.96), and sustained ventricular tachycardia (0.2% vs 0.1%, p = 0.32) between patients receiving and not receiving intravenous contrast, respectively. In conclusion, severe adverse reactions to intravenous contrast agents during stress echocardiography are uncommon. Contrast use does not add to the baseline risk for severe adverse events in patients who undergo stress echocardiography.

  3. Intravascular forward-looking ultrasound transducers for microbubble-mediated sonothrombolysis.

    Science.gov (United States)

    Kim, Jinwook; Lindsey, Brooks D; Chang, Wei-Yi; Dai, Xuming; Stavas, Joseph M; Dayton, Paul A; Jiang, Xiaoning

    2017-06-14

    Effective removal or dissolution of large blood clots remains a challenge in clinical treatment of acute thrombo-occlusive diseases. Here we report the development of an intravascular microbubble-mediated sonothrombolysis device for improving thrombolytic rate and thus minimizing the required dose of thrombolytic drugs. We hypothesize that a sub-megahertz, forward-looking ultrasound transducer with an integrated microbubble injection tube is more advantageous for efficient thrombolysis by enhancing cavitation-induced microstreaming than the conventional high-frequency, side-looking, catheter-mounted transducers. We developed custom miniaturized transducers and demonstrated that these transducers are able to generate sufficient pressure to induce cavitation of lipid-shelled microbubble contrast agents. Our technology demonstrates a thrombolysis rate of 0.7 ± 0.15 percent mass loss/min in vitro without any use of thrombolytic drugs.

  4. Effervescent agents in the double contrast examination of the stomach

    International Nuclear Information System (INIS)

    Virkkunen, P.; Kreula, J.

    1981-01-01

    The buffer capacities of the BaSO 4 contrast media are poor. Yet the pH changes caused by effervescent agents or gastric contents are insignificant for mucosal adsorption. The increase of the viscosity and decrease of the density impair the results of the examination. (Auth.)

  5. Investigation of contrast agent dosage for perfusion-weighted MRI

    International Nuclear Information System (INIS)

    Erb, G.; Benner, T.; Heiland, S.; Reith, W.; Sartor, K.; Forsting, M.

    1997-01-01

    Purpose: In this study we investigated, whether increasing the dosage of a paramagnetic contrast agent results in a stronger signal decrease in T 2 *-weighted perfusion sequences and therefore more meaningful parameter maps. Material and methods: In a prospective study bolus injection of gadolinium-DTPA was performed at dosages of 0.1, 0.2, and 0.3 mmol/kg body weight (BW) in 10 patients each. Before, during and after bolus injection 40 T 2 *-weighted images of a reference brain slice were acquired within 65.6 seconds on a 1.0 T clinical scanner and perfusion parameters were calculated. Results: Due to the limited signal decrease during bolus passage and the resulting low signal-difference-to-noise ratio (ΔS/N) no reliable differentiation of gray and white matter was possible at a contrast agent dosage of 0.1 mmol/kg BW. Only at higher dosages, both, signal decrease and ΔS/N were strong enough to allow differentiation of gray and white matter and to yield reliable parameter maps. Conclusion: For meaningful MR perfusion imaging at 1.0 T and with the given sequence a contrast agent dosage of at least 0.2 mmol/kg BW is necessary, if a 0.5-molar contrast agent is used. (orig.) [de

  6. Severe reactions to iodinated contrast agents: is anaphylaxis responsible?

    International Nuclear Information System (INIS)

    Dewachter, P.; Mouton-Faivre, C.

    2001-01-01

    The etiology of severe reactions following injection of iodinated contrast agent is the subject of controversy. No consensus has been established regarding the management of patients at risk, risk factors and pre-medication because in most cases published no diagnostic exploration has been carried out on patients who have experienced a severe reaction. Diagnosis of drug anaphylaxis is based on clinical history, proof of mediator release and drug specific IgE antibodies (when the technique is available) or cutaneous tests (when direct technique is not available). This approach has been adopted for etiologic diagnosis of 5 clinical cases of severe anaphylactoid reactions (including one death) following the injection of ionic and non ionic contrast agents. Clinical symptoms, biology and cutaneous tests are consistent with anaphylaxis. Any patient who has had a severe anaphylactoid reaction following injection of a contrast agent should undergo an allergology assessment to confirm the diagnosis and identify the culprit contrast agent. Indeed, no pre-medication has proved efficient for the prevention of subsequent allergic reactions. (author)

  7. The use of contrast agents in cardiac MRI

    International Nuclear Information System (INIS)

    Maurer, A.H.; Osbakken, M.

    1988-01-01

    Inherent NMR phenomena such as T/sub 1/ and T/sub 2/, and proton density can be used to provide tissue contrast on MR images. However, there are times when this contrast is not sufficient or does not provide tissue characterization data sufficient for use in definition of a pathophysiological insult. In this later case, paramagnetic agents might be of use in enhancement of relaxation time differences in one tissue or one portion of a tissue compared to another. Although several agents have been evaluated in this regard, most have been found inadequate because of their tissue toxicity. At present, gadolinium diethylenetriamine pentaacetric acid (Gd-DTPA) (which is an agent used in nuclear medicine studies) appears to be a good agent to use to distinguish normal from ischemic tissue. This agent has been used by a number of investigators to evaluate myocardial ischemia and provides images with better sensitivity and specificity for ischemia than imaging techniques using natural tissue contrast based on T/sub 1/ and T/sub 2/ differences

  8. Macromolecular and dendrimer-based magnetic resonance contrast agents

    Energy Technology Data Exchange (ETDEWEB)

    Bumb, Ambika; Brechbiel, Martin W. (Radiation Oncology Branch, National Cancer Inst., National Inst. of Health, Bethesda, MD (United States)), e-mail: pchoyke@mail.nih.gov; Choyke, Peter (Molecular Imaging Program, National Cancer Inst., National Inst. of Health, Bethesda, MD (United States))

    2010-09-15

    Magnetic resonance imaging (MRI) is a powerful imaging modality that can provide an assessment of function or molecular expression in tandem with anatomic detail. Over the last 20-25 years, a number of gadolinium-based MR contrast agents have been developed to enhance signal by altering proton relaxation properties. This review explores a range of these agents from small molecule chelates, such as Gd-DTPA and Gd-DOTA, to macromolecular structures composed of albumin, polylysine, polysaccharides (dextran, inulin, starch), poly(ethylene glycol), copolymers of cystamine and cystine with GD-DTPA, and various dendritic structures based on polyamidoamine and polylysine (Gadomers). The synthesis, structure, biodistribution, and targeting of dendrimer-based MR contrast agents are also discussed

  9. [Development of Biliary Contrast Agents Remote Pushing Device].

    Science.gov (United States)

    Zhu, Haoyang; Dong, Dinghui; Luo, Yu; Ren, Fenggang; Zhang, Jing; Tan, Wenjun; Shi, Aihua; Hu, Liangshuo; Wu, Rongqian; Lyu, Yi

    2018-01-30

    A biliary contrast agents pushing device, including a syringe pushing system and a remote controller is introduced. The syringe pushing system comprises an injector card slot, a support platform and an injection bolus fader. A 20 mL syringe can be fitted on the syringe pushing system and kept with the ground about 30 degree. This system can perform air bubble pumping back and contrast agents bolus injection as well as speed adjustment. Remote controller is an infrared remote control which can start and stop the syringe pushing system. With this device, the remote controlled cholangiography technology can be achieved, which can not only protect doctors from X-ray radiation but also improve the traditional T-tube cholangiography and the contrast effect, reduce postoperative complications in patients as well. The application of this device will improve the current diagnosis and treatment system, the device will benefit the majority of doctors and patients.

  10. Counter-propagating wave interaction for contrast-enhanced ultrasound imaging

    International Nuclear Information System (INIS)

    Renaud, G; Bosch, J G; Ten Kate, G L; De Jong, N; Van der Steen, A F W; Shamdasani, V; Entrekin, R

    2012-01-01

    Most techniques for contrast-enhanced ultrasound imaging require linear propagation to detect nonlinear scattering of contrast agent microbubbles. Waveform distortion due to nonlinear propagation impairs their ability to distinguish microbubbles from tissue. As a result, tissue can be misclassified as microbubbles, and contrast agent concentration can be overestimated; therefore, these artifacts can significantly impair the quality of medical diagnoses. Contrary to biological tissue, lipid-coated gas microbubbles used as a contrast agent allow the interaction of two acoustic waves propagating in opposite directions (counter-propagation). Based on that principle, we describe a strategy to detect microbubbles that is free from nonlinear propagation artifacts. In vitro images were acquired with an ultrasound scanner in a phantom of tissue-mimicking material with a cavity containing a contrast agent. Unlike the default mode of the scanner using amplitude modulation to detect microbubbles, the pulse sequence exploiting counter-propagating wave interaction creates no pseudoenhancement behind the cavity in the contrast image. (fast track communication)

  11. A biomarker-responsive T2ex MRI contrast agent.

    Science.gov (United States)

    Daryaei, Iman; Randtke, Edward A; Pagel, Mark D

    2017-04-01

    This study investigated a fundamentally new type of responsive MRI contrast agent for molecular imaging that alters T 2 exchange (T 2ex ) properties after interacting with a molecular biomarker. The contrast agent Tm-DO3A-oAA was treated with nitric oxide (NO) and O 2 . The R 1 and R 2 relaxation rates of the reactant and product were measured with respect to concentration, temperature, and pH. Chemical exchange saturation transfer (CEST) spectra of the reactant and product were acquired using a 7 Tesla (T) MRI scanner and analyzed to estimate the chemical exchange rates and r 2ex relaxivities. The reaction of Tm-DO3A-oAA with NO and O 2 caused a 6.4-fold increase in the r 2 relaxivity of the agent, whereas r 1 relaxivity remained unchanged, which demonstrated that Tm-DO3A-oAA is a responsive T 2ex agent. The effects of pH and temperature on the r 2 relaxivities of the reactant and product supported the conclusion that the product's benzimidazole ligand caused the agent to have a fast chemical exchange rate relative to the slow exchange rate of the reactant's ortho-aminoanilide ligand. T 2ex MRI contrast agents are a new type of responsive agent that have good detection sensitivity and specificity for detecting a biomarker, which can serve as a new tool for molecular imaging. Magn Reson Med 77:1665-1670, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  12. In Vivo Assessment of the Potential for Renal Bio-Effects from the Vaporization of Perfluorocarbon Phase-Change Contrast Agents.

    Science.gov (United States)

    Nyankima, A Gloria; Rojas, Juan D; Cianciolo, Rachel; Johnson, Kennita A; Dayton, Paul A

    2018-02-01

    Low-boiling-point perfluorocarbon phase-change contrast agents (PCCAs) provide an alternative to microbubble contrast agents. Although parameter ranges related to in vivo bio-effects of microbubbles are fairly well characterized, few studies have been done to evaluate the potential of bio-effects related to PCCAs. To bridge this gap, we present an assessment of biological effects (e.g., hemorrhage) related to acoustically excited PCCAs in the rodent kidney. The presence or absence of bio-effects was observed after sonication with various perfluorocarbon core PCCAs (decafluorobutane, octafluoropropane or a 1:1 mixture) and as a function of activation pulse mechanical index (MI; minimum activation threshold, which was a moderate MI of 0.81-1.35 vs. a clinical maximum of 1.9). Bio-effects on renal tissue were assessed through hematology and histology including measurement of blood creatinine levels and the quantity of red blood cell (RBC) casts present in hematoxylin and eosin-stained kidney tissue sections after sonication. Short-term (24 h) and long-term (2 and 4 wk) analyses were performed after treatment. Results indicated that bio-effects from PCCA vaporization were not observed at lower mechanical indices. At higher mechanical indices, bio-effects were observed at 24 h, although these were not observable 2 wk after treatment. Copyright © 2018. Published by Elsevier Inc.

  13. Non-linear Response and Viscoelastic Properties of Lipid-Coated Microbubbles: DSPC versus DPPC

    NARCIS (Netherlands)

    van Rooij, T.; Luan, Y.; Renaud, G.; van der Steen, A.F.W.; Versluis, Michel; de Jong, N.; Kooiman, K.

    2015-01-01

    For successful in vivo contrast-enhanced ultrasound imaging (CEUS) and ultrasound molecular imaging, detailed knowledge of stability and acoustical properties of the microbubbles is essential. Here, we compare these aspects of lipid-coated microbubbles that have either

  14. Contrast enhanced cartilage imaging: Comparison of ionic and non-ionic contrast agents

    International Nuclear Information System (INIS)

    Wiener, Edzard; Woertler, Klaus; Weirich, Gregor; Rummeny, Ernst J.; Settles, Marcus

    2007-01-01

    Our objective was to compare relaxation effects, dynamics and spatial distributions of ionic and non-ionic contrast agents in articular cartilage at concentrations typically used for direct MR arthrography at 1.5 T. Dynamic MR-studies over 11 h were performed in 15 bovine patella specimens. For each of the contrast agents gadopentetate dimeglumine, gadobenate dimeglumine, gadoteridol and mangafodipir trinatrium three patellae were placed in 2.5 mmol/L contrast solution. Simultaneous measurements of T 1 and T 2 were performed every 30 min using a high-spatial-resolution 'MIX'-sequence. T 1 , T 2 and ΔR 1 , ΔR 2 profile plots across cartilage thickness were calculated to demonstrate the spatial and temporal distributions. The charge is one of the main factors which controls the amount of the contrast media diffusing into intact cartilage, but independent of the charge, the spatial distribution across cartilage thickness remains highly inhomogeneous even after 11 h of diffusion. The absolute ΔR 2 -effect in cartilage is at least as large as the ΔR 1 -effect for all contrast agents. Maximum changes were 5-12 s -1 for ΔR 1 and 8-15 s -1 for ΔR 2 . This study indicates that for morphologically intact cartilage only the amount of contrast agents within cartilage is determined by the charge but not the spatial distribution across cartilage thickness. In addition, ΔR 2 can be considered for quantification of contrast agent concentrations, since it is of the same magnitude and less time consuming to measure than ΔR 1

  15. The advantage of high relaxivity contrast agents in brain perfusion

    International Nuclear Information System (INIS)

    Cotton, F.; Hermier, M.

    2006-01-01

    Accurate MRI characterization of brain lesions is critical for planning therapeutic strategy, assessing prognosis and monitoring response to therapy. Conventional MRI with gadolinium-based contrast agents is useful for the evaluation of brain lesions, but this approach primarily depicts areas of disruption of the blood-brain barrier (BBB) rather than tissue perfusion. Advanced MR imaging techniques such as dynamic contrast agent-enhanced perfusion MRI provide physiological information that complements the anatomic data available from conventional MRI. We evaluated brain perfusion imaging with gadobenate dimeglumine (Gd-BOPTA, MultiHance; Bracco Imaging, Milan, Italy). The contrast-enhanced perfusion technique was performed on a Philips Intera 1.5-T MR system. The technique used to obtain perfusion images was dynamic susceptibility contrast-enhanced MRI, which is highly sensitive to T2* changes. Combined with PRESTO perfusion imaging, SENSE is applied to double the temporal resolution, thereby improving the signal intensity curve fit and, accordingly, the accuracy of the derived parametric images. MultiHance is the first gadolinium MR contrast agent with significantly higher T1 and T2 relaxivities than conventional MR contrast agents. The higher T1 relaxivity, and therefore better contrast-enhanced T1-weighted imaging, leads to significantly improved detection of BBB breakdown and hence improved brain tumor conspicuity and delineation. The higher T2 relaxivity allows high-quality T2*-weighted perfusion MRI and the derivation of good quality relative cerebral blood volume (rCBV) maps. We determined the value of MultiHance for enhanced T2*-weighted perfusion imaging of histologically proven (by surgery or stereotaxic biopsy) intraaxial brain tumors (n=80), multiple sclerosis lesions (n=10), abscesses (n=4), neurolupus (n=15) and stroke (n=16). All the procedures carried out were safe and no adverse events occurred. The acquired perfusion images were of good quality in

  16. Advanced Contrast Agents for Multimodal Biomedical Imaging Based on Nanotechnology.

    Science.gov (United States)

    Calle, Daniel; Ballesteros, Paloma; Cerdán, Sebastián

    2018-01-01

    Clinical imaging modalities have reached a prominent role in medical diagnosis and patient management in the last decades. Different image methodologies as Positron Emission Tomography, Single Photon Emission Tomography, X-Rays, or Magnetic Resonance Imaging are in continuous evolution to satisfy the increasing demands of current medical diagnosis. Progress in these methodologies has been favored by the parallel development of increasingly more powerful contrast agents. These are molecules that enhance the intrinsic contrast of the images in the tissues where they accumulate, revealing noninvasively the presence of characteristic molecular targets or differential physiopathological microenvironments. The contrast agent field is currently moving to improve the performance of these molecules by incorporating the advantages that modern nanotechnology offers. These include, mainly, the possibilities to combine imaging and therapeutic capabilities over the same theranostic platform or improve the targeting efficiency in vivo by molecular engineering of the nanostructures. In this review, we provide an introduction to multimodal imaging methods in biomedicine, the sub-nanometric imaging agents previously used and the development of advanced multimodal and theranostic imaging agents based in nanotechnology. We conclude providing some illustrative examples from our own laboratories, including recent progress in theranostic formulations of magnetoliposomes containing ω-3 poly-unsaturated fatty acids to treat inflammatory diseases, or the use of stealth liposomes engineered with a pH-sensitive nanovalve to release their cargo specifically in the acidic extracellular pH microenvironment of tumors.

  17. Microfluidics-based microbubbles in methylene blue solution for photoacoustic and ultrasound imaging

    Science.gov (United States)

    Das, Dhiman; Sivasubramanian, Kathyayini; Yang, Chun; Pramanik, Manojit

    2018-02-01

    Contrast agents which can be used for more than one bio-imaging technique has gained a lot of attention from researchers in recent years. In this work, a microfluidic device employing a flow-focusing junction, is used for the continuous generation of monodisperse nitrogen microbubbles in methylene blue, an optically absorbing organic dye, for dual-modal photoacoustic and ultrasound imaging. Using an external phase of polyoxyethylene glycol 40 stearate (PEG 40), a non-ionic surfactant, and 50% glycerol solution at a flow rate of 1 ml/hr and gas pressure at 1.75 bar, monodisperse nitrogen microbubbles of diameter 7 microns were obtained. The external phase also contained methylene blue hydrate at a concentration of 1 gm/litre. The monodisperse microbubbles produced a strong ultrasound signal as expected. It was observed that the signal-to-noise (SNR) ratio of the photoacoustic signal for the methylene blue solution in the presence of the monodisperse microbubbles was 68.6% lower than that of methylene blue solution in the absence of microbubbles. This work is of significance because using microfluidics, we can precisely control the bubbles' production rate and bubble size which increases ultrasound imaging efficiency. A uniform size distribution of the bubbles will have narrower resonance frequency bandwidth which will respond well to specific ultrasound frequencies.

  18. Novel MR imaging contrast agents for cancer detection

    Directory of Open Access Journals (Sweden)

    Daryoush Shahbazi-Gahrouei

    2009-05-01

    Full Text Available

    • BACKGROUND: Novel potential MR imaging contrast agents Gd-tetra-carboranylmethoxyphenyl-porphyrin (Gd-TCP, Gd-hematoporphyrin (Gd-H, Gd-DTPA-9.2.27 against melanoma, Gd-DTPA-WM53 against leukemia and Gd-DTPAC595 against breast cancer cells were synthesized and applied to mice with different human cancer cells (melanoma MM-138, leukemia HL-60, breast MCF-7. The relaxivity, the biodistribution, T1 relaxation times, and signal enhancement of the contrast agents are presented and the results are compared.
    • METHODS: After preparation of contrast agents, the animal studies were performed. The cells (2×106 cells were injected subcutaneously in the both flanks of mice. Two to three weeks after tumor plantation, when the tumor diameter was 2-4 mm, mice were injected with the different contrast agents. The animals were sacrificed at 24 hr post IP injection followed by removal of critical organs. The T1 relaxation times and signal intensities of samples were measured using 11.4 T magnetic field and Gd concentration were measured using UV-spectrophotometer.
    • RESULTS: For Gd-H, the percent of Gd localized to the tumors measured by UV-spect was 28, 23 and 21 in leukemia, melanoma and breast cells, respectively. For Gd-TCP this amount was 21%, 18% and 15%, respectively. For Gd-DTPA-9.2.27, Gd-DTPA-WM53 and Gd-DTPA-C595 approximately 35%, 32% and 27% of gadolinium localized to their specific tumor, respectively.
    • CONCLUSION: The specific studied conjugates showed good tumor uptake in the relevant cell lines and low levels of Gd in the liver, kidney and spleen. The studied agents have considerable promise for further diagnosis applications of MR imaging.
    • KEYWORDS: Magnetic Resonance, Imaging, Monoclonal Antibody, Contrast Agents, Gadolinium, Early Detection of Cancer.

  19. Ferrimagnetic ferritin cage nanoparticles used as MRI contrast agent

    Science.gov (United States)

    Cai, Y.; Cao, C.; Zhang, T.; Xu, H.; Pan, Y.

    2017-12-01

    The nano-sized ferrimagnetic ferritin cage nanoparticles are ideal materials for understanding of superparamagnetism, biomimetic synthesis of ultrafine magnetic particles and their application in biomedicine. Ferrimagnetic M-HFn nanoparticles with size of magnetite cores in a mean size ranges from 2.7 nm to 5.3 nm were synthesized through loading different amount of iron into recombinant human H chain ferritin (HFn) shells. Both the saturation magnetization (Ms) and blocking temperature (Tb) were increased with the size of ferrimagnetic cores. In essence, magnetic resonance imaging (MRI) analysis showed that the synthesized M-HFn nanoparticles (5.3 nm magnetite core) has extremely high transverse relaxivity (r2) values up to 320.9 mM-1S-1, which indicate that M-HFn nanoparticles are promising negative contrast agent in early detection of tumors. In addition, the longitudinal relaxivity (r1) (10.4 mM-1S-1) and r2/r1 ratio ( 2.2) of M-HFn nanoparticles ( 2.7 nm magnetite core in diameter) will make it a considerable potential as a positive contrast agent in MRI. This means the M-HFn nanoparticles can be used as dual functional MR contrast agent. Acute toxicity study of M-HFn in rats showed that a dosage of 20 mg Fe/kg makes no abnormalities by serum biochemical and hematological analysis as well as histopathological examination. Compared with a similar commercial contrast agent, combidex (with a clinical dosage of 2.7 mg Fe/kg), it indicates that M-HFn nanoparticle is of a relative safe ferrimagnetic nanoparticle when used in vivo.

  20. Beat frequency ultrasonic microsphere contrast agent detection system

    Science.gov (United States)

    Pretlow, III, Robert A. (Inventor); Yost, William T. (Inventor); Cantrell, Jr., John H. (Inventor)

    1997-01-01

    A system for and method of detecting and measuring concentrations of an ultrasonically-reflective microsphere contrast agent involving detecting non-linear sum and difference beat frequencies produced by the microspheres when two impinging signals with non-identical frequencies are combined by mixing. These beat frequencies can be used for a variety of applications such as detecting the presence of and measuring the flow rates of biological fluids and industrial liquids, including determining the concentration level of microspheres in the myocardium.

  1. Modified Gadonanotubes as a Promising Novel MRI Contrasting Agent

    OpenAIRE

    Rouzbeh Jahanbakhsh; Fatemeh Atyabi; Saeed Shanehsazzadeh; Zahra Sobhani; Mohsen Adeli; Rassoul Dinarvand

    2013-01-01

    Background and purpose of the study Carbon nanotubes (CNTs) are emerging drug and imaging carrier systems which show significant versatility. One of the extraordinary characteristics of CNTs as Magnetic Resonance Imaging (MRI) contrasting agent is the extremely large proton relaxivities when loaded with gadolinium ion (Gdn 3+) clusters. Methods In this study equated Gdn 3+ clusters were loaded in the sidewall defects of oxidized multiwalled (MW) CNTs. The amount of loaded gadolinium ion into ...

  2. Photoacoustic imaging at 1064nm wavelength with exogenous contrast agents

    Science.gov (United States)

    Upputuri, Paul Kumar; Jiang, Yuyan; Pu, Kanyi; Pramanik, Manojit

    2018-02-01

    Photoacoustic (PA) imaging is a promising imaging modality for both preclinical research and clinical practices. Laser wavelengths in the first near infrared window (NIR-I, 650-950 nm) have been widely used for photoacoustic imaging. As compared with NIR-I window, scattering of photons by biological tissues is largely reduced in the second NIR (NIR-II) window, leading to enhanced imaging fidelity. However, the lack of biocompatible NIR-II absorbing exogenous agents prevented the use of this window for in vivo imaging. In recent years, few studies have been reported on photoacoustic imaging in NIR-II window using exogenous contrast agents. In this work, we discuss the recent work on PA imaging using 1064 nm wavelength, the fundamental of Nd:YAG laser, as an excitation wavelength. The PA imaging at 1064 nm is advantageous because of the low and homogeneous signal from tissue background, enabling high contrast in PA imaging when NIR-II absorbing contrast agents are employed.

  3. Towards MRI T2 contrast agents of increased efficiency

    Energy Technology Data Exchange (ETDEWEB)

    Branca, Marlène [CNRS, LCC (Laboratoire de Chimie de Coordination), 205, route de Narbonne, F-31077 Toulouse (France); Université de Toulouse, UPS, INPT, LCC, F-31077 Toulouse (France); Marciello, Marzia, E-mail: marziamarciello@icmm.csic.es [Instituto de Ciencia de Materiales de Madrid (ICMM-CSIC), Sor Juana Inés de la Cruz, 3, Cantoblanco, 28049 Madrid (Spain); Ciuculescu-Pradines, Diana [CNRS, LCC (Laboratoire de Chimie de Coordination), 205, route de Narbonne, F-31077 Toulouse (France); Université de Toulouse, UPS, INPT, LCC, F-31077 Toulouse (France); Respaud, Marc [LPCNO, INSA, 135 Avenue de Rangueil, 31077 Toulouse Cedex 4 (France); Morales, Maria del Puerto [Instituto de Ciencia de Materiales de Madrid (ICMM-CSIC), Sor Juana Inés de la Cruz, 3, Cantoblanco, 28049 Madrid (Spain); Serra, Raphael; Casanove, Marie-José [CNRS, CEMES (Centre d' Elaboration des Matériaux et d' Etudes Structurales) (France); Amiens, Catherine, E-mail: catherine.amiens@lcc-toulouse.fr [CNRS, LCC (Laboratoire de Chimie de Coordination), 205, route de Narbonne, F-31077 Toulouse (France); Université de Toulouse, UPS, INPT, LCC, F-31077 Toulouse (France)

    2015-03-01

    Magnetic nanoparticles can be efficient contrast agents for T2 weighted magnetic resonance imaging (MRI) after tuning of some key parameters such as size, surface state, colloidal stability and magnetization, thus motivating the development of new synthetic pathways. In this paper we report the effects of surface coating on the efficiency of two different types of iron based nanoparticles (NPs) as MRI contrast agents. Starting from well-defined hydrophobic iron oxide nanospheres and iron nanocubes of 13 nm size, we have used three methods to increase their hydrophilicity and transfer them into water: surface ligand modification, ligand exchange or encapsulation. The NPs obtained have been characterized by dynamic light scattering and transmission electron microscopy, and the relaxivities of their stable colloidal solutions in water have been determined. Among all samples prepared, iron nanocubes coated by silica display the highest relaxivity (r{sub 2}) value: 628 s{sup −1} mM{sup −1}. - Highlights: • Surface coating effect on the efficiency of iron based nanoparticles (NPs) as MRI contrast agents. • Synthesis of 2 different types of hydrophobic iron based NPs: iron oxide nanospheres and iron nanocubes (13 nm). • Development of three different procedures to stabilize iron based NPs in water. • Iron nanocubes coated by silica displayed the highest r{sub 2} value (628 s{sup −1} mM{sup −1})

  4. Effects of contrast agents on the fallopian tube in a rabbit model

    International Nuclear Information System (INIS)

    Moore, D.E.

    1989-01-01

    Selection of the optimal contrast agent for hysterosalpingography was the focus of this study. The authors have evaluated the effect of different iodinated contrast agents on the fallopian tube of a rabbit. Ethiodol (oil-soluble contrast agent), methylglucamine iothalomate (water-soluble ionic agent) 30% and 60%, and Ioxilan (water-soluble monionic contrast agent) were compared. The agents were introduced by fallopian tube catheterization. Findings suggested that nonionic water-soluble contrast agents were the least detrimental to the fallopian tube and surrounding tissue. Iothalomate 60% resulted in mild inflammatory changes. Oil-soluble contrast agents caused granulomatous reaction and fibrinous adhesions

  5. Dual Contrast - Magnetic Resonance Fingerprinting (DC-MRF): A Platform for Simultaneous Quantification of Multiple MRI Contrast Agents.

    Science.gov (United States)

    Anderson, Christian E; Donnola, Shannon B; Jiang, Yun; Batesole, Joshua; Darrah, Rebecca; Drumm, Mitchell L; Brady-Kalnay, Susann M; Steinmetz, Nicole F; Yu, Xin; Griswold, Mark A; Flask, Chris A

    2017-08-16

    Injectable Magnetic Resonance Imaging (MRI) contrast agents have been widely used to provide critical assessments of disease for both clinical and basic science imaging research studies. The scope of available MRI contrast agents has expanded over the years with the emergence of molecular imaging contrast agents specifically targeted to biological markers. Unfortunately, synergistic application of more than a single molecular contrast agent has been limited by MRI's ability to only dynamically measure a single agent at a time. In this study, a new Dual Contrast - Magnetic Resonance Fingerprinting (DC - MRF) methodology is described that can detect and independently quantify the local concentration of multiple MRI contrast agents following simultaneous administration. This "multi-color" MRI methodology provides the opportunity to monitor multiple molecular species simultaneously and provides a practical, quantitative imaging framework for the eventual clinical translation of molecular imaging contrast agents.

  6. Preclinical Studies of a Kidney Safe Iodinated Contrast Agent.

    Science.gov (United States)

    Rowe, Elizabeth S; Rowe, Vernon D; Biswas, Sangita; Mosher, Gerold; Insisienmay, Lovella; Ozias, Marlies K; Gralinski, Michael R; Hunter, John; Barnett, James S

    2016-09-01

    Contrast-induced acute kidney injury (CI-AKI) is a serious complication of the use of iodinated contrast agents. This problem is particularly acute in interventional neurology and interventional cardiology, probably due to the intra-arterial route of injection, high contrast volumes, and preexisting risk factors of these patients. In an attempt to develop a contrast agent that is less damaging to the kidneys, we have studied the effects of adding a small amount of the substituted cyclodextrin, sulfobutyl-ether-β-cyclodextrin (SBECD), to iohexol in rodent models of renal toxicity. Renally compromised mice and rats were injected with iohexol and iohexol-SBECD via the tail vein. The renal pathology, creatinine clearance, and survival benefits of iohexol-SBECD were studied. The safety of direct intra-arterial injection of the iohexol-SBECD formulation was studied in a dog heart model system. Mechanism of action studies in cell culture model using a human kidney cell line was performed using flow cytometry. Nephrotoxicity was significantly reduced using iohexol-SBECD compared to iohexol alone, at mole ratios of iohexol:SBECD of 1:0.025. SBECD increased survival from 50% to 88% in a rat survival study. In the dog heart model, iohexol-SBECD was safe. Cell culture studies suggest that SBECD interferes with the early stages of contrast-induced apoptosis in a human renal cell line. We have shown that the addition of a small amount of SBECD (one molecule of SBECD per 40 iohexol molecules) significantly protects rodent kidneys from CI-AKI. Further development of this new formulation of iodinated contrast is warranted. © 2016 The Authors. Journal of Neuroimaging published by Wiley Periodicals, Inc. on behalf of American Society of Neuroimaging.

  7. Biocompatible Nanocomplexes for Molecular Targeted MRI Contrast Agent

    Science.gov (United States)

    Chen, Zhijin; Yu, Dexin; Wang, Shaojie; Zhang, Na; Ma, Chunhong; Lu, Zaijun

    2009-07-01

    Accurate diagnosis in early stage is vital for the treatment of Hepatocellular carcinoma. The aim of this study was to investigate the potential of poly lactic acid-polyethylene glycol/gadolinium-diethylenetriamine-pentaacetic acid (PLA-PEG/Gd-DTPA) nanocomplexes using as biocompatible molecular magnetic resonance imaging (MRI) contrast agent. The PLA-PEG/Gd-DTPA nanocomplexes were obtained using self-assembly nanotechnology by incubation of PLA-PEG nanoparticles and the commercial contrast agent, Gd-DTPA. The physicochemical properties of nanocomplexes were measured by atomic force microscopy and photon correlation spectroscopy. The T1-weighted MR images of the nanocomplexes were obtained in a 3.0 T clinical MR imager. The stability study was carried out in human plasma and the distribution in vivo was investigated in rats. The mean size of the PLA-PEG/Gd-DTPA nanocomplexes was 187.9 ± 2.30 nm, and the polydispersity index was 0.108, and the zeta potential was -12.36 ± 3.58 mV. The results of MRI test confirmed that the PLA-PEG/Gd-DTPA nanocomplexes possessed the ability of MRI, and the direct correlation between the MRI imaging intensities and the nano-complex concentrations was observed ( r = 0.987). The signal intensity was still stable within 2 h after incubation of the nanocomplexes in human plasma. The nanocomplexes gave much better image contrast effects and longer stagnation time than that of commercial contrast agent in rat liver. A dose of 0.04 mmol of gadolinium per kilogram of body weight was sufficient to increase the MRI imaging intensities in rat livers by five-fold compared with the commercial Gd-DTPA. PLA-PEG/Gd-DTPA nanocomplexes could be prepared easily with small particle sizes. The nanocomplexes had high plasma stability, better image contrast effect, and liver targeting property. These results indicated that the PLA-PEG/Gd-DTPA nanocomplexes might be potential as molecular targeted imaging contrast agent.

  8. Biocompatible Nanocomplexes for Molecular Targeted MRI Contrast Agent

    Directory of Open Access Journals (Sweden)

    Yu Dexin

    2009-01-01

    Full Text Available Abstract Accurate diagnosis in early stage is vital for the treatment of Hepatocellular carcinoma. The aim of this study was to investigate the potential of poly lactic acid–polyethylene glycol/gadolinium–diethylenetriamine-pentaacetic acid (PLA–PEG/Gd–DTPA nanocomplexes using as biocompatible molecular magnetic resonance imaging (MRI contrast agent. The PLA–PEG/Gd–DTPA nanocomplexes were obtained using self-assembly nanotechnology by incubation of PLA–PEG nanoparticles and the commercial contrast agent, Gd–DTPA. The physicochemical properties of nanocomplexes were measured by atomic force microscopy and photon correlation spectroscopy. The T1-weighted MR images of the nanocomplexes were obtained in a 3.0 T clinical MR imager. The stability study was carried out in human plasma and the distribution in vivo was investigated in rats. The mean size of the PLA–PEG/Gd–DTPA nanocomplexes was 187.9 ± 2.30 nm, and the polydispersity index was 0.108, and the zeta potential was −12.36 ± 3.58 mV. The results of MRI test confirmed that the PLA–PEG/Gd–DTPA nanocomplexes possessed the ability of MRI, and the direct correlation between the MRI imaging intensities and the nano-complex concentrations was observed (r = 0.987. The signal intensity was still stable within 2 h after incubation of the nanocomplexes in human plasma. The nanocomplexes gave much better image contrast effects and longer stagnation time than that of commercial contrast agent in rat liver. A dose of 0.04 mmol of gadolinium per kilogram of body weight was sufficient to increase the MRI imaging intensities in rat livers by five-fold compared with the commercial Gd–DTPA. PLA–PEG/Gd–DTPA nanocomplexes could be prepared easily with small particle sizes. The nanocomplexes had high plasma stability, better image contrast effect, and liver targeting property. These results indicated that the PLA–PEG/Gd–DTPA nanocomplexes might be potential as molecular

  9. Contrast Materials

    Science.gov (United States)

    ... is mixed with water before administration liquid paste tablet When iodine-based and barium-sulfate contrast materials ... for patients with kidney failure or allergies to MRI and/or computed tomography (CT) contrast material. Microbubble ...

  10. Therapeutic response assessment of percutaneous radiofrequency ablation for hepatocellular carcinoma: Utility of contrast-enhanced agent detection imaging

    International Nuclear Information System (INIS)

    Kim, Chan Kyo; Choi, Dongil; Lim, Hyo K.; Kim, Seung Hoon; Lee, Won Jae; Kim, Min Ju; Lee, Ji Yeon; Jeon, Yong Hwan; Lee, Jongmee; Lee, Soon Jin; Lim, Jae Hoon

    2005-01-01

    Purpose: To assess the utility of contrast-enhanced agent detection imaging (ADI) in the assessment of the therapeutic response to percutaneous radiofrequency (RF) ablation in patients with hepatocellular carcinoma (HCC). Materials and methods: Ninety patients with a total of 97 nodular HCCs (mean, 2.1 ± 1.3 cm; range, 1.0-5.0 cm) treated with percutaneous RF ablation under the ultrasound guidance were evaluated with contrast-enhanced ADI after receiving an intravenous bolus injection of a microbubble contrast agent (SH U 508A). We obtained serial contrast-enhanced ADI images during the time period from 15 to 90 s after the initiation of the bolus contrast injection. All of the patients underwent a follow-up four-phase helical CT at 1 month after RF ablation, which was then repeated at 2-4 month intervals during a period of at least 12 months. The results of the contrast-enhanced ADI were compared with those of the follow-up CT in terms of the presence or absence of residual unablated tumor and local tumor progression in the treated lesions. Results: On contrast-enhanced ADI, technical success was obtained in 94 (97%) of the 97 HCCs, while residual unablated tumors were found in three HCCs (3%). Two of the three tumors that were suspicious (was not proven) for incomplete ablation were subjected to additional RF ablation. The remaining one enhancing lesion that was suspicious of a residual tumor on contrast-enhanced ADI was revealed to be reactive hyperemia at the 1-month follow-up CT. Therefore; the diagnostic concordance between the contrast-enhanced ADI and 1-month follow-up CT was 99%. Of the 94 ablated HCCs without residual tumors on both the contrast-enhanced ADI and 1-month follow-up CT after the initial RF ablation, five (5%) had CT findings of local tumor progression at a subsequent follow-up CT. Conclusion: Despite its limitations in predicting local tumor progression in the treated tumors, contrast-enhanced ADI is potentially useful for evaluating the

  11. A smart magnetic resonance contrast agent for selective copper sensing.

    Science.gov (United States)

    Que, Emily L; Chang, Christopher J

    2006-12-20

    We describe the synthesis and properties of Copper-Gad-1 (CG1), a new type of smart magnetic resonance (MR) sensor for selective detection of copper. CG1 is composed of a gadolinium contrast agent core tethered to copper-selective recognition motif. Cu2+-induced modulation of inner-sphere water access to the Gd3+ center provides a sensing mechanism for reporting Cu2+ levels by reading out changes in longitudinal proton relaxivity values. CG1 features good selectivity for Cu2+ over abundant biological cations and a 41% increase in relaxivity upon Cu2+ binding and is capable of detecting micromolar changes in Cu2+ concentrations in aqueous media.

  12. Colorectal liver metastases: contrast agent diffusion coefficient for quantification of contrast enhancement heterogeneity at MR imaging.

    Science.gov (United States)

    Jia, Guang; O'Dell, Craig; Heverhagen, Johannes T; Yang, Xiangyu; Liang, Jiachao; Jacko, Richard V; Sammet, Steffen; Pellas, Theodore; Cole, Patricia; Knopp, Michael V

    2008-09-01

    To describe and determine the reproducibility of a simplified model to quantitatively measure heterogeneous intralesion contrast agent diffusion in colorectal liver metastases. This HIPAA-compliant retrospective study received institutional review board approval, and written informed consent was obtained from 14 patients (mean age, 61 years +/- 9 [standard deviation]; range, 41-78 years), including 10 men (mean age, 65 years +/- 8; range, 47-78 years) and four women (mean age, 54 years +/- 9; range, 41-59 years), with colorectal liver metastases. Magnetic resonance (MR) imaging was performed twice (first baseline MR image [B(1)] and second baseline MR image [B(2)]) in a single target lesion prior to therapy. Dynamic contrast material-enhanced MR imaging was performed by using a saturation-recovery fast gradient-echo sequence. A simplified contrast agent diffusion model was proposed, and a contrast agent diffusion coefficient (CDC) was calculated. The reproducibility of the CDC measurement was evaluated by using the Bland-Altman plot and a linear regression model. The mean CDC was 0.22 mm(2)/sec (range, 0.01-0.73 mm(2)/sec) on B(1) and 0.24 mm(2)/sec (range, 0.01-0.71 mm(2)/sec) on B(2), with an intraclass correlation coefficient of 0.91 (P < .0001). Bland-Altman plot showed good agreement, with a mean difference in measurement pairs of 0.017 mm(2)/sec +/- 0.096. The slope from the linear regression model was 0.89 (95% confidence interval: 0.63, 1.15) and the intercept was 0.01 (95% confidence interval: -0.08, 0.09). The CDC enables a quantitative description of contrast enhancement heterogeneity in lesions. Given the high reproducibility of the CDC metric, CDC appears promising for further qualification as an imaging biomarker of change measurement in response assessment. http://radiology.rsnajnls.org/cgi/content/full/248/3/901/DC1. RSNA, 2008

  13. Micro-radiography of biological samples with medical contrast agents

    International Nuclear Information System (INIS)

    Dammer, J.; Weyda, F.; Benes, J.; Sopko, V.; Gelbic, I.

    2013-01-01

    Micro-radiography is an imaging technique that uses X-rays to study the internal structures of objects. This fast and easy imaging tool is based on differential X-ray attenuation by various tissues and structures within biological samples. The experimental setup described is based on the semiconductor pixel X-ray detector Medipix2 and X-ray micro-focus tube. Our micro-radiographic system has been recently used not only for the examination of internal structures of various arthropods and other biological objects but also for tracing some processes in selected model species (we used living larvae of mosquito Culex quinquefasciatus). Low concentrations of iodine, lanthanum or gold particles were used as a tracer (contrast agent). Such contrast agents increase the absorption of X-rays and allow a better visibility of internal structures of model organisms (especially the various cavities, pores, etc.). In addition, the movement of tracers in selected timing experiments demonstrates some physiological functions of digestive and excretory system

  14. Micro-radiography of biological samples with medical contrast agents

    Energy Technology Data Exchange (ETDEWEB)

    Dammer, J., E-mail: jiri.dammer@lf1.cuni.cz [Charles University in Prague, First Faculty of Medicine, Salmovská 1, 120 00 Prague 2 (Czech Republic); Hospital Na Bulovce, Department of Radiological Physics, Budinova 2, 180 81 Prague 8 (Czech Republic); Institute of Experimental and Applied Physics, Czech Technical University in Prague, Horska 3a/22, 128 00 Prague 2 (Czech Republic); Weyda, F. [Faculty of Science, University of South Bohemia, Branisovska 31, 370 05 Ceske Budejovice (Czech Republic); Benes, J. [Charles University in Prague, First Faculty of Medicine, Salmovská 1, 120 00 Prague 2 (Czech Republic); Sopko, V. [Hospital Na Bulovce, Department of Radiological Physics, Budinova 2, 180 81 Prague 8 (Czech Republic); Institute of Experimental and Applied Physics, Czech Technical University in Prague, Horska 3a/22, 128 00 Prague 2 (Czech Republic); Gelbic, I. [Biology Centre, AS CR, Institute of Entomology, Department of Biochemistry and Physiology, Branisovska 31, CZ-37005 Ceske Budejovice (Czech Republic)

    2013-12-01

    Micro-radiography is an imaging technique that uses X-rays to study the internal structures of objects. This fast and easy imaging tool is based on differential X-ray attenuation by various tissues and structures within biological samples. The experimental setup described is based on the semiconductor pixel X-ray detector Medipix2 and X-ray micro-focus tube. Our micro-radiographic system has been recently used not only for the examination of internal structures of various arthropods and other biological objects but also for tracing some processes in selected model species (we used living larvae of mosquito Culex quinquefasciatus). Low concentrations of iodine, lanthanum or gold particles were used as a tracer (contrast agent). Such contrast agents increase the absorption of X-rays and allow a better visibility of internal structures of model organisms (especially the various cavities, pores, etc.). In addition, the movement of tracers in selected timing experiments demonstrates some physiological functions of digestive and excretory system.

  15. Viscosity of iodinated contrast agents during renal excretion

    International Nuclear Information System (INIS)

    Jost, Gregor; Lengsfeld, Philipp; Lenhard, Diana C.; Pietsch, Hubertus; Huetter, Joachim; Sieber, Martin A.

    2011-01-01

    Objective: Modern iodinated non-ionic contrast agents (CAs) can be classified based on their molecular structure into monomeric and dimeric CAs and have at comparable iodine concentrations a different viscosity and osmolality. During their renal excretion, CAs are concentrated in the renal tubuli which might enhance the viscosity difference between monomeric and dimeric CAs. The viscosity of a CA might have an underestimated importance for renal safety, as suggested by recent publications. In this study, we investigated the viscosities of CAs at the concentrations expected to be present in renal tubules. This concentration process was simulated in vitro using dialysis. Furthermore, we investigated urine viscosity and urine flow in rodents after administration of several non-ionic monomeric and dimeric CAs. Materials and methods: To estimate the viscosity of the CAs in vivo, we performed an in vitro dialysis of monomeric and dimeric CAs at various physiological osmolalities of the renal tubulus (290, 400, 500, 700 and 1000 mOsm/kg H 2 O). Following the dialysis, the iodine concentrations and the viscosities of the CAs were determined. Furthermore, to investigate the concentration process in vivo, we measured the urine viscosity and the urine flow in Han Wister rats after the administration of Iopromide, Iohexol, Ioversol, Iomeprol, Iodixanol, and Iosimenol at comparable iodine concentrations. As a control, saline was injected at the same volume. Results: In vitro dialysis of the dimeric CA increased the iodine concentration and strongly increased the viscosity at all tested osmolalities. In contrast, for the monomeric agents an increase in concentration and viscosity was observed only at 700 as well 1000 mOsm/kg H 2 O but to a lesser extent. In summary, dialysis strongly enhanced the viscosity differences between the non-ionic monomeric and dimeric CAs. The administration of dimeric CAs leads to a strong increase in urine viscosity; this was not observed for the

  16. Viscosity of iodinated contrast agents during renal excretion

    Energy Technology Data Exchange (ETDEWEB)

    Jost, Gregor, E-mail: Gregor.Jost@bayer.com [TRG Diagnostic Imaging, Bayer Schering Pharma AG, Berlin (Germany); Lengsfeld, Philipp, E-mail: Philipp.Lengsfeld@bayer.com [Global Medical Affairs Diagnostic Imaging, Bayer Schering Pharma AG, Berlin (Germany); Lenhard, Diana C., E-mail: Diana.Lenhard@bayer.com [TRG Diagnostic Imaging, Bayer Schering Pharma AG, Berlin (Germany); Pietsch, Hubertus, E-mail: Hubertus.Pietsch@bayer.com [TRG Diagnostic Imaging, Bayer Schering Pharma AG, Berlin (Germany); Huetter, Joachim, E-mail: Joachim.Huetter@bayer.com [TRG Diagnostic Imaging, Bayer Schering Pharma AG, Berlin (Germany); Sieber, Martin A., E-mail: Martin.Sieber@bayer.com [TRG Diagnostic Imaging, Bayer Schering Pharma AG, Berlin (Germany)

    2011-11-15

    Objective: Modern iodinated non-ionic contrast agents (CAs) can be classified based on their molecular structure into monomeric and dimeric CAs and have at comparable iodine concentrations a different viscosity and osmolality. During their renal excretion, CAs are concentrated in the renal tubuli which might enhance the viscosity difference between monomeric and dimeric CAs. The viscosity of a CA might have an underestimated importance for renal safety, as suggested by recent publications. In this study, we investigated the viscosities of CAs at the concentrations expected to be present in renal tubules. This concentration process was simulated in vitro using dialysis. Furthermore, we investigated urine viscosity and urine flow in rodents after administration of several non-ionic monomeric and dimeric CAs. Materials and methods: To estimate the viscosity of the CAs in vivo, we performed an in vitro dialysis of monomeric and dimeric CAs at various physiological osmolalities of the renal tubulus (290, 400, 500, 700 and 1000 mOsm/kg H{sub 2}O). Following the dialysis, the iodine concentrations and the viscosities of the CAs were determined. Furthermore, to investigate the concentration process in vivo, we measured the urine viscosity and the urine flow in Han Wister rats after the administration of Iopromide, Iohexol, Ioversol, Iomeprol, Iodixanol, and Iosimenol at comparable iodine concentrations. As a control, saline was injected at the same volume. Results: In vitro dialysis of the dimeric CA increased the iodine concentration and strongly increased the viscosity at all tested osmolalities. In contrast, for the monomeric agents an increase in concentration and viscosity was observed only at 700 as well 1000 mOsm/kg H{sub 2}O but to a lesser extent. In summary, dialysis strongly enhanced the viscosity differences between the non-ionic monomeric and dimeric CAs. The administration of dimeric CAs leads to a strong increase in urine viscosity; this was not observed for

  17. Quinone-fused porphyrins as contrast agents for photoacoustic imaging

    KAUST Repository

    Banala, Srinivas

    2017-06-27

    Photoacoustic (PA) imaging is an emerging non-invasive diagnostic modality with many potential clinical applications in oncology, rheumatology and the cardiovascular field. For this purpose, there is a high demand for exogenous contrast agents with high absorption coefficients in the optical window for tissue imaging, i.e. the near infrared (NIR) range between 680 and 950 nm. We herein report the photoacoustic properties of quinone-fused porphyrins inserted with different transition metals as new highly promising candidates. These dyes exhibit intense NIR absorption, a lack of fluorescence emission, and PA sensitivity in concentrations below 3 nmol mL. In this context, the highest PA signal was obtained with a Zn(ii) inserted dye. Furthermore, this dye was stable in blood serum and free thiol solution and exhibited negligible cell toxicity. Additionally, the Zn(ii) probe could be detected with an up to 3.2 fold higher PA intensity compared to the clinically most commonly used PA agent, ICG. Thus, further exploration of the \\'quinone-fusing\\' approach to other chromophores may be an efficient way to generate highly potent PA agents that do not fluoresce and shift their absorption into the NIR range.

  18. Use of carbon dioxide as an intravascular contrast agent: A review of current literature

    OpenAIRE

    Ali, Fahad; Mangi, Muhammad Asif; Rehman, Hiba; Kaluski, Edo

    2017-01-01

    Use of X-ray contrast allows us to differentiate between two or more adjacent structures on radiographic studies. The X-ray contrast agent can be the one with increase X-ray absorption, like iodine and a barium X-ray contrast agent or the one with decrease X-ray absorption like air and carbon dioxide contrast agent. Each contrast agent possesses different risks and benefits in various ways. Carbon dioxide as an intravascular contrast agent can be used as an alternative intravascular contrast ...

  19. Noninvasive Ambient Pressure Estimation using Ultrasound Contrast Agents -- Invoking Subharmonics for Cardiac and Hepatic Applications

    Science.gov (United States)

    Dave, Jaydev K.

    Ultrasound contrast agents (UCAs) are encapsulated microbubbles that provide a source for acoustic impedance mismatch with the blood, due to difference in compressibility between the gas contained within these microbubbles and the blood. When insonified by an ultrasound beam, these UCAs act as nonlinear scatterers and enhance the echoes of the incident pulse, resulting in scattering of the incident ultrasound beam and emission of fundamental (f0), subharmonic (f0/2), harmonic (n*f0; n ∈ N) and ultraharmonic (((2n-1)/2)*f0; n ∈ N & n > 1) components in the echo response. A promising approach to monitor in vivo pressures revolves around the fact that the ultrasound transmit and receive parameters can be selected to induce an ambient pressure amplitude dependent subharmonic signal. This subharmonic signal may be used to estimate ambient pressure amplitude; such technique of estimating ambient pressure amplitude is referred to as subharmonic aided pressure estimation or SHAPE. This project develops and evaluates the feasibility of SHAPE to noninvasively monitor cardiac and hepatic pressures (using commercially available ultrasound scanners and UCAs) because invasive catheter based pressure measurements are used currently for these applications. Invasive catheter based pressure measurements pose risk of introducing infection while the catheter is guided towards the region of interest in the body through a percutaneous incision, pose risk of death due to structural or mechanical failure of the catheter (which has also triggered product recalls by the USA Food and Drug Administration) and may potentially modulate the pressures that are being measured. Also, catheterization procedures require fluoroscopic guidance to advance the catheter to the site of pressure measurements and such catheterization procedures are not performed in all clinical centers. Thus, a noninvasive technique to obtain ambient pressure values without the catheterization process is clinically

  20. Contrast agents for tumor diagnosis in magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Goto, Rensuke; Doi, Hisayoshi; Okada, Shoji [University of Shizuoka (Japan). School of Pharmaceutical Science; Yano, Masayuki; Katano, Susumu; Nakajima, Nobuaki

    1992-01-01

    In order to develop contrast agents for tumor diagnosis in magnetic resonance imaging (MRI), we investigated the effects of several gadolinium complexes on T{sub 1} relaxation time of proton in some tissues of Ehrlich solid tumor-bearing mice. L-Aspartic acid, L-glutamic acid, DL-homocysteine, L-glutamyl-glutamic acid, glutathione, sperimidine and ethylenediaminetetrakis (methylenephosphate) (EDTMP) were used as ligands for Gd{sup 3+}. Since each Gd-complex could not be purified except Gd-EDTMP, the mixture of GdCl{sub 3} and a ligand was administered intravenously. Among the compounds tested, the mixture of aspartic acid, glutathione or spermidine with GdCl{sub 3} showed almost the same or above reduction of T{sub 1} relaxation times in the tumor tissue compared with Gd-diethylenetriamine pentaacetic acid (Gd-DTPA) which is used clinically. Furthermore, the contrast-enhancing effect of the three mixtures in the tumor was observed by in vivo T{sub 1}-weighted magnetic resonance imaging. The in vivo tissue distribution using radioactive {sup 153}Gd{sup 3+} showed that these mixtures mentioned above were also taken up more highly in the tumor than {sup 153}GdCl{sub 3} itself and {sup 153}Gd-DTPA, suggesting the formation of Gd-complexes. However, the overall tissue distribution of the mixtures was similar to that of {sup 153}GdCl{sub 3} because the Gd-complexes were not purified. Gd-EDTMP exhibited the almost same effects with Gd-DTPA as a contrast agent. (author).

  1. Contrast-enhanced harmonic endoscopic ultrasound

    DEFF Research Database (Denmark)

    Săftoiu, A; Dietrich, C F; Vilmann, P

    2012-01-01

    Second-generation intravenous blood-pool ultrasound contrast agents are increasingly used in endoscopic ultrasound (EUS) for characterization of microvascularization, differential diagnosis of benign and malignant focal lesions, and improving staging and guidance of therapeutic procedures. Although...... initially used as Doppler signal enhancers, second-generation microbubble contrast agents are now used with specific contrast harmonic imaging techniques, which benefit from the highly nonlinear behavior of the microbubbles. Contrast-specific modes based on multi-pulse technology are used to perform...... contrast-enhanced harmonic EUS based on a very low mechanical index (0.08 - 0.12). Quantification techniques based on dynamic contrast-enhanced ultrasound have been recommended for perfusion imaging and monitoring of anti-angiogenic treatment, mainly based on time-intensity curve analysis. Most...

  2. Cellulose nanoparticles: photoacoustic contrast agents that biodegrade to simple sugars

    Science.gov (United States)

    Jokerst, Jesse V.; Bohndiek, Sarah E.; Gambhir, Sanjiv S.

    2014-03-01

    In photoacoustic imaging, nanoparticle contrast agents offer strong signal intensity and long-term stability, but are limited by poor biodistribution and clearance profiles. Conversely, small molecules offer renal clearance, but relatively low photoacoustic signal. Here we describe a cellulose-based nanoparticle with photoacoustic signal superior to gold nanorods, but that undergoes enzymatic cleavage into constituent glucose molecules for renal clearance. Cellulose nanoparticles (CNPs) were synthesized through acidic cleavage of cellulose linters and purified with centrifugation. TEM indicated that the nanoparticles were 132 +/- 46 nm; the polydispersity index was 0.138. Ex vivo characterization showed a photoacoustic limit of detection of 0.02 mg/mL CNPs, and the photoacoustic signal of CNPs was 1.5- to 3.0-fold higher than gold nanorods (also at 700 nm resonance) on a particle-to-particle basis. Cell toxicity assays suggested that overnight doses below 0.31 mg/mL CNPs produced no significant (p>0.05) impact on cell metabolism. Intravenous doses up to 0.24 mg were tolerated well in nude mice. Subcutaneous and orthotopic tumor xenografts of the OV2008 ovarian cancer cell line were then created in nude mice. Data was collected with a Nexus128 scanner from Endra LifeSciences. Spectral data used a LAZR system from Visualsonics both at 700 nm excitation. We injected CNPs (0.024 mg, 0.048 mg, and 0.80 mg) via tail vein and showed that the tumor photoacoustic signal reached maximum increase between 10 and 20 minutes. All injected concentrations were statistically (p0.96 suggesting quantitative signal. CNP biodegradation was demonstrated ex vivo with a glucose assay. CNPs in the presence of cellulase were reduced to free glucose in under than four hours. The glucose concentration before addition of cellulase was not detectable, but increased to 92.1 μg/mL in four hours. CNPs in the absence of cellulase did not produce glucose. Small fragments of nanoparticle in the

  3. Evaluation of clot formation in blood-contrast agent mixture: experimental study on ionic/nonionic contrast agents and plastic/ glass syringes

    International Nuclear Information System (INIS)

    Shim, Hyung Jin; Lee, Jong Beum; Lee, Yong Chul; Lee, Kwan Seh; Kim, Kun Sang

    1991-01-01

    Recent introduction of low-osmolar nonionic contrast agents has allowed the performance of angiography with certain advantages such as reduced pain, reduced osmotic load and other potential advantages, over high osmolar ionic contrast agents. But the potential thrombogenic risk of nonionic contrast agent has been debate because of their weak anticoagulation effect. Several reports have recently documented the formation of thrombi in catheters and syringes containing nonionic contrast agent, and thromboembolic episodes have been noted during angiographic procedures. We have also been experienced blood clotting within blood mixed contrast agent syringe during angiography. Thus, we have studied with blood mixed ionic (Diatrizoate, Ioglicate) agents and nonionic (Iopamidol, Iopromide) agents, that used usually in our hospital, and saline in plastic and glass syringes. Each syringes were checked the clot formation on 10,30,60,90 minutes. Total 340 samples were obtained from 8 adults before angiography. Our data showed that nonionic contrast agents had significantly lesser anticoagulation effect than ionic contrast agents (ρ < 0.0001) on Chi-square test), both in plastic and glass syringes. And formation of clotting in glass syringes were significantly greater than that in plastic syringes (ρ < 0.0001). Thus meticulous technique is required to prevent thrombosis during angiographic procedure using nonionic contrast agents

  4. Instrumentation for contrast echocardiography: technology and techniques.

    Science.gov (United States)

    Kaul, Sanjiv

    2002-11-18

    Contrast echocardiography is the only clinical imaging technique in which the imaging modality (ultrasound) can cause a change in the contrast agent (microbubbles). The change in the contrast agent can range from small oscillations of the microbubbles at a low mechanical index to their disruption at a high mechanical index. The specific mechanical index required to produce these various effects may be different for each contrast agent, depending on the bubble dimension as well as shell and gas characteristics. These alterations in bubbles result in changes in ultrasound backscatter that are specific for the bubbles themselves, rather than for tissue, and are therefore exploited for imaging their presence in tissue. These signal-processing techniques have resulted in an increased signal-to-noise ratio from bubbles vis-à-vis the tissue and have made online assessment of myocardial perfusion possible.

  5. Tracers and contrast agents in cardiovascular imaging: present and future

    International Nuclear Information System (INIS)

    Marmion, M.; Deutsch, E.

    1996-01-01

    This brief article addresses the current status and future potential of nuclear medicine, X-ray computed tomography (CT), ultrasound (US), and magnetic resonance (MR) imaging in the diagnosis of cardiovascular diseases. The currently perceived advantages and disadvantages, as well as the possible future roles, of each of the modalities with regard to the evaluation of coronary artery disease are delineated. The certain advent of Mr and US myocardial contrast agents, combined with the inexorable pressures of health care reform, will alter the future usage patterns of all four modalities. Future debates about which modality should be used in which clinical situation will be based not on 'anatomy vs function', nor on the issues of cost effectiveness and patient outcomes

  6. Magnetic susceptibility imaging with a nonionic contrast agent

    International Nuclear Information System (INIS)

    Cacheris, W.; Rocklage, S.M.; Quay, S.; Dow, W.; Love, D.; Worah, D.; Lim, K.

    1988-01-01

    The magnetic susceptibility mechanism for MR imaging contrast enhancement has the advantage of providing useful information, such as cerebral blood flow, without crossing the blood-brain barrier. In this paper the authors report the use of a highly effective, relatively nontoxic chelate as a magnetic susceptibility agent. Dy-DTPA-bis(methylamide) (Dy-DTPA-BMA) has an extremely low acute toxicity (LD-50, intravenous, mice ∼ 40 mmol/kg). Doses of 1 mmol/kg and 2 mmol/kg Dy-DTPA-BMA lowered the initial signal intensity 63% to 57%, respectively. The utility of this technique in detecting areas of reduced blood flow within the brain was demonstrated by imaging a rabbit with a cerebral perfusion deficit

  7. A model for ultrasound contrast agent in a phantom vessel

    KAUST Repository

    Qamar, Adnan

    2014-02-01

    A theoretical framework to model the dynamics of Ultrasound Contrast Agent (UCA) inside a phantom vessel is presented. The model is derived from the reduced Navier-Stokes equation and is coupled with the evolving flow field solution inside the vessel by a similarity transformation approach. The results are computed, and compared with experiments available in literature, for the initial UCA radius of Ro=1.5 μm and 2 μm for the vessel diameter of D=12 μm and 200 μm with the acoustic parameters as utilized in the experiments. When compared to other models, better agreement on smaller vessel diameter is obtained with the proposed coupled model. The model also predicts, quite accurately, bubble fragmentation in terms of acoustic and geometric parameters. © 2014 IEEE.

  8. Mn-DPDP, the first contrast agent for the pancreas

    International Nuclear Information System (INIS)

    Gehl, H.B.; Vorwerk, D.; Klose, K.C.; Raber, H.; Guenther, R.W.

    1990-01-01

    Mn-DPDP, known as a contrast agent for the hepatobiliary system, shows signal intensity increase of the pancreas as well. This paper describes the extent of signal intensity increase in the pancreas as a function of time. Six healthy volunteers were imaged with a 1.5-T MR unit using a T1-weighted gradient-echo sequence. Acquisitions were taken in 3-minute intervals for the first 45 minutes, followed by intervals of 30 minutes for 7 hours after infusion of Mn-DPDP. As a special formulation, 10 μmol per kg Mn-DPDP were infused. The enhancement of the head and the tail of the pancreas were measured and plotted as a function of time; the percentage increase in pancreas signal intensity was calculated and compared with the increase in liver signal intensity

  9. The use of contrast agent for imaging biological samples

    Energy Technology Data Exchange (ETDEWEB)

    Dammer, J; Sopko, V; Jakubek, J [Institute of Experimental and Applied Physics, Czech Technical University in Prague, Horska 3a/22, CZ 12800 Prague 2 (Czech Republic); Weyda, F, E-mail: jiri.dammer@utef.cvut.cz [Biological center of the Academy of Sciences of the Czech Republic, Institute of Entomology, Branisovska 31, CZ-37005 Ceske Budejovice (Czech Republic)

    2011-01-15

    The technique of X-ray transmission imaging has been available for over a century and is still among the fastest and easiest approaches to the studies of internal structure of biological samples. Recent advances in semiconductor technology have led to the development of new types of X-ray detectors with direct conversion of interacting X-ray photon to an electric signal. Semiconductor pixel detectors seem to be specially promising; compared to the film technique, they provide single-quantum and real-time digital information about the objects being studied. We describe the recently developed radiographic apparatus, equipped with Medipix2 semiconductor pixel detector. The detector is used as an imager that counts individual photons of ionizing radiation, emitted by an X-ray tube (micro- or nano-focus FeinFocus). Thanks to the wide dynamic range of the Medipix2 detector and its high spatial resolution better than 1{mu}m, the setup is particularly suitable for radiographic imaging of small biological samples, including in-vivo observations with contrast agent (Optiray). Along with the description of the apparatus we provide examples of the use iodine contrast agent as a tracer in various insects as model organisms. The motivation of our work is to develop our imaging techniques as non-destructive and non-invasive. Microradiographic imaging helps detect organisms living in a not visible environment, visualize the internal biological processes and also to resolve the details of their body (morphology). Tiny live insects are an ideal object for our studies.

  10. Gadolinium chloride as a contrast agent for imaging wood composite components by magnetic resonance

    Science.gov (United States)

    Thomas L. Eberhardt; Chi-Leung So; Andrea Protti; Po-Wah So

    2009-01-01

    Although paramagnetic contrast agents have an established track record in medical uses of magnetic resonance imaging (MRI), only recently has a contrast agent been used for enhancing MRI images of solid wood specimens. Expanding on this concept, wood veneers were treated with a gadolinium-based contrast agent and used in a model system comprising three-ply plywood...

  11. Correlation of contrast agent kinetics between iodinated contrast-enhanced spectral tomosynthesis and gadolinium-enhanced MRI of breast lesions

    International Nuclear Information System (INIS)

    Froeling, Vera; Diekmann, Felix; Renz, Diane M.; Fallenberg, Eva M.; Steffen, Ingo G.; Diekmann, Susanne; Schmitzberger, Florian F.; Lawaczeck, Ruediger

    2013-01-01

    Assessment of contrast agent kinetics in contrast-enhanced MRI (CE-MRI) with gadolinium-containing contrast agents offers the opportunity to predict breast lesion malignancy. The goal of our study was to determine if similar patterns exist for spectral contrast-enhanced digital breast tomosynthesis (CE-DBT) using an iodinated contrast agent. The protocol of our prospective study was approved by the relevant institutional review board and the German Federal Office for Radiation Protection. All patients provided written informed consent. We included 21 women with a mean age of 62.4 years. All underwent ultrasound-guided biopsy of a suspect breast lesion, spectral CE-DBT and CE-MRI. For every breast lesion, contrast agent kinetics was assessed by signal intensity-time curves for spectral CE-DBT and CE-MRI. Statistical comparison used Cohen's kappa and Spearman's rho test. Spearman's rho of 0.49 showed significant (P = 0.036) correlation regarding the contrast agent kinetics in signal intensity-time curves for spectral CE-DBT and CE-MRI. Cohen's kappa indicated moderate agreement (kappa = 0.438). There is a statistically significant correlation between contrast agent kinetics in the signal intensity-time curves for spectral CE-DBT and CE-MRI. Observing intralesional contrast agent kinetics in spectral CE-DBT may aid evaluation of malignant breast lesions. (orig.)

  12. Cyanine 5.5 conjugated nanobubbles as a tumor selective contrast agent for dual ultrasound-fluorescence imaging in a mouse model.

    Directory of Open Access Journals (Sweden)

    Liyi Mai

    Full Text Available Nanobubbles and microbubbles are non-invasive ultrasound imaging contrast agents that may potentially enhance diagnosis of tumors. However, to date, both nanobubbles and microbubbles display poor in vivo tumor-selectivity over non-targeted organs such as liver. We report here cyanine 5.5 conjugated nanobubbles (cy5.5-nanobubbles of a biocompatible chitosan-vitamin C lipid system as a dual ultrasound-fluorescence contrast agent that achieved tumor-selective imaging in a mouse tumor model. Cy5.5-nanobubble suspension contained single bubble spheres and clusters of bubble spheres with the size ranging between 400-800 nm. In the in vivo mouse study, enhancement of ultrasound signals at tumor site was found to persist over 2 h while tumor-selective fluorescence emission was persistently observed over 24 h with intravenous injection of cy5.5-nanobubbles. In vitro cell study indicated that cy5.5-flurescence dye was able to accumulate in cancer cells due to the unique conjugated nanobubble structure. Further in vivo fluorescence study suggested that cy5.5-nanobubbles were mainly located at tumor site and in the bladder of mice. Subsequent analysis confirmed that accumulation of high fluorescence was present at the intact subcutaneous tumor site and in isolated tumor tissue but not in liver tissue post intravenous injection of cy5.5-nanobubbles. All these results led to the conclusion that cy5.5-nanobubbles with unique crosslinked chitosan-vitamin C lipid system have achieved tumor-selective imaging in vivo.

  13. Are gadolinium contrast agents suitable for gadolinium neutron capture therapy?

    Science.gov (United States)

    De Stasio, Gelsomina; Rajesh, Deepika; Casalbore, Patrizia; Daniels, Matthew J; Erhardt, Robert J; Frazer, Bradley H; Wiese, Lisa M; Richter, Katherine L; Sonderegger, Brandon R; Gilbert, Benjamin; Schaub, Sebastien; Cannara, Rachel J; Crawford, John F; Gilles, Mary K; Tyliszczak, Tolek; Fowler, John F; Larocca, Luigi M; Howard, Steven P; Mercanti, Delio; Mehta, Minesh P; Pallini, Roberto

    2005-06-01

    Gadolinium neutron capture therapy (GdNCT) is a potential treatment for malignant tumors based on two steps: (1) injection of a tumor-specific (157)Gd compound; (2) tumor irradiation with thermal neutrons. The GdNC reaction can induce cell death provided that Gd is proximate to DNA. Here, we studied the nuclear uptake of Gd by glioblastoma (GBM) tumor cells after treatment with two Gd compounds commonly used for magnetic resonance imaging, to evaluate their potential as GdNCT agents. Using synchrotron X-ray spectromicroscopy, we analyzed the Gd distribution at the subcellular level in: (1) human cultured GBM cells exposed to Gd-DTPA or Gd-DOTA for 0-72 hours; (2) intracerebrally implanted C6 glioma tumors in rats injected with one or two doses of Gd-DOTA, and (3) tumor samples from GBM patients injected with Gd-DTPA. In cell cultures, Gd-DTPA and Gd-DOTA were found in 84% and 56% of the cell nuclei, respectively. In rat tumors, Gd penetrated the nuclei of 47% and 85% of the tumor cells, after single and double injection of Gd-DOTA, respectively. In contrast, in human GBM tumors 6.1% of the cell nuclei contained Gd-DTPA. Efficacy of Gd-DTPA and Gd-DOTA as GdNCT agents is predicted to be low, due to the insufficient number of tumor cell nuclei incorporating Gd. Although multiple administration schedules in vivo might induce Gd penetration into more tumor cell nuclei, a search for new Gd compounds with higher nuclear affinity is warranted before planning GdNCT in animal models or clinical trials.

  14. Apparition of iodinated contrast agents in twin neonatal gastrointestinal tracts after maternal contrast-enhanced computed tomography

    International Nuclear Information System (INIS)

    Kato, Hiroki; Kanematsu, Masayuki; Kato, Zenichiro; Kondo, Naomi; Orii, Kenji E.; Morimoto, Masahiro

    2011-01-01

    We describe a case of the appearance of iodinated contrast agents in the same locations of twins' neonatal gastrointestinal tracts 1 day after maternal contrast-enhanced computed tomography (CT). The CT examination had been performed on the expectant mother for suspected deep venous thrombosis on the day previous to the twin delivery. At 23 h after the CT examination and after cesarean section, iodinated contrast agents appeared in the same place in the twins' neonatal gastrointestinal tracts, mainly in the ascending colon, on plain abdominal radiographs. Radiologists, obstetricians, and pediatricians should understand the mechanism of appearance of iodinated contrast agents in fetal gastrointestinal tracts when the expectant mother had been given iodinated contrast agents intravenously shortly before delivery. (author)

  15. Gauging the likelihood of stable cavitation from ultrasound contrast agents.

    Science.gov (United States)

    Bader, Kenneth B; Holland, Christy K

    2013-01-07

    The mechanical index (MI) was formulated to gauge the likelihood of adverse bioeffects from inertial cavitation. However, the MI formulation did not consider bubble activity from stable cavitation. This type of bubble activity can be readily nucleated from ultrasound contrast agents (UCAs) and has the potential to promote beneficial bioeffects. Here, the presence of stable cavitation is determined numerically by tracking the onset of subharmonic oscillations within a population of bubbles for frequencies up to 7 MHz and peak rarefactional pressures up to 3 MPa. In addition, the acoustic pressure rupture threshold of an UCA population was determined using the Marmottant model. The threshold for subharmonic emissions of optimally sized bubbles was found to be lower than the inertial cavitation threshold for all frequencies studied. The rupture thresholds of optimally sized UCAs were found to be lower than the threshold for subharmonic emissions for either single cycle or steady state acoustic excitations. Because the thresholds of both subharmonic emissions and UCA rupture are linearly dependent on frequency, an index of the form I(CAV) = P(r)/f (where P(r) is the peak rarefactional pressure in MPa and f is the frequency in MHz) was derived to gauge the likelihood of subharmonic emissions due to stable cavitation activity nucleated from UCAs.

  16. State and development of new clinical contrast agents for MR diagnosis of liver diseases

    International Nuclear Information System (INIS)

    Rummeny, E.J.; Peters, P.E.

    1992-01-01

    MR contrast agents are developed for pharmaceutical manipulation of tissue signal intensities. Today it is widely recognized that MR contrast agents will play an increasingly important role in MR imaging of the liver. Contrast-enhanced MR-imaging allows to obtain simultaneously dynamic physiologic information and high anatomci detail. Up to now three major classes of MR contrast agents are available for clinical MR-imaging of the liver. These include paramagnetic perfusion agents, hepatobiliary agents, and superparamagnetic RES-specific iron oxide particles. A fourth class of contrast agents now in use for animal experiments includes ultrasmall superparamagnetic particles which can be targeted to extrareticuloendothelial structures such as asialoglycoprotein receptors of hepatocytes. In this article, we review recent advances in the development of MR contrast media and the clinical of contrast-enhanced MR imaging of the liver. (orig.) [de

  17. Can aquatic macrophytes be biofilters for gadolinium based contrasting agents?

    Science.gov (United States)

    Braun, Mihály; Zavanyi, Györgyi; Laczovics, Attila; Berényi, Ervin; Szabó, Sándor

    2018-05-15

    The use of gadolinium-based contrasting agents (GBCA) is increasing because of the intensive usage of these agents in magnetic resonance imaging (MRI). Waste-water treatment does not reduce anthropogenic Gd-concentration significantly. Anomalous Gd-concentration in surface waters have been reported worldwide. However, removal of GBCA-s by aquatic macrophytes has still hardly been investigated. Four aquatic plant species (Lemna gibba, Ceratophyllum demersum, Elodea nuttallii, E. canadensis) were investigated as potential biological filters for removal of commonly used but structurally different GBCA-s (Omniscan, Dotarem) from water. These plant species are known to accumulate heavy metals and are used for removing pollutants in constructed wetlands. The Gd uptake and release of the plants was examined under laboratory conditions. Concentration-dependent infiltration of Gd into the body of the macrophytes was measured, however significant bioaccumulation was not observed. The tissue concentration of Gd reached its maximum value between day one and four in L. gibba and C. demersum, respectively, and its volume was significantly higher in C. demersum than in L. gibba. In C. demersum, the open-chain ligand Omniscan causes two-times higher tissue Gd concentration than the macrocyclic ligand Dotarem. Gadolinium was released from Gd-treated duckweeds into the water as they were grown further in Gd-free nutrient solution. Tissue Gd concentration dropped by 50% in duckweed treated by Omniscan and by Dotarem within 1.9 and 2.9 days respectively. None of the macrophytes had a significant impact on the Gd concentration of water in low and medium concentration levels (1-256 μg L -1 ). Biofiltration of GBCA-s by common macrophytes could not be detected in our experiments. Therefore it seems that in constructed wetlands, aquatic plants are not able to reduce the concentration of GBCA-s in the water. Furthermore there is a low risk that these plants cause the

  18. Double agents and secret agents: the emerging fields of exogenous chemical exchange saturation transfer and T2-exchange magnetic resonance imaging contrast agents for molecular imaging.

    Science.gov (United States)

    Daryaei, Iman; Pagel, Mark D

    2015-01-01

    Two relatively new types of exogenous magnetic resonance imaging contrast agents may provide greater impact for molecular imaging by providing greater specificity for detecting molecular imaging biomarkers. Exogenous chemical exchange saturation transfer (CEST) agents rely on the selective saturation of the magnetization of a proton on an agent, followed by chemical exchange of a proton from the agent to water. The selective detection of a biomarker-responsive CEST signal and an unresponsive CEST signal, followed by the ratiometric comparison of these signals, can improve biomarker specificity. We refer to this improvement as a "double-agent" approach to molecular imaging. Exogenous T 2 -exchange agents also rely on chemical exchange of protons between the agent and water, especially with an intermediate rate that lies between the slow exchange rates of CEST agents and the fast exchange rates of traditional T 1 and T 2 agents. Because of this intermediate exchange rate, these agents have been relatively unknown and have acted as "secret agents" in the contrast agent research field. This review exposes these secret agents and describes the merits of double agents through examples of exogenous agents that detect enzyme activity, nucleic acids and gene expression, metabolites, ions, redox state, temperature, and pH. Future directions are also provided for improving both types of contrast agents for improved molecular imaging and clinical translation. Therefore, this review provides an overview of two new types of exogenous contrast agents that are becoming useful tools within the armamentarium of molecular imaging.

  19. Erythrocytes as Carriers for Drugs and Contrast Agents

    Directory of Open Access Journals (Sweden)

    Mauro Magnani

    2014-01-01

    of new biomimetic constructs that now permits the use of these nanomaterials in vivo avoiding their rapid sequestration and their accumulation in unwanted districts (PCT WO 2008/003524 A3. Similarly, the encapsulation of infrared fluorescent agents into RBC gives opportunity to the measurement of vasomotion in the human retinal vasculature suggesting a possible correlation with retinal edema. In summary, the newly developed RBC-based drug delivery system is an innovative technology platform that could be used in a wide range of applications opening to unlimited new therapeutic approaches. Furthermore, the same system has been adapted to deliver contrasting agents within the body enabling the improvement of current fluorangiographic procedures and the imaging by Magnetic Resonance (MRI and Magnetic Particle (MPI. EryDel S.p.A. has recently completed trials to bring EryDex treatment to the market and to implement the clinical applications of the RBC technology.

  20. Contrast Enhanced US in the Abdomen

    International Nuclear Information System (INIS)

    Chung, Yong Eun; Kim, Ki Whang

    2012-01-01

    Contrast enhanced ultrasound, which was introduced in 1996, has been widely used in Europe and Eastern Asia. Ultrasound contrast agent can be classified as first generation and second generation, depending on the gas within the microbubble. With the first generation contrast agent, the high MI technique was used, and only intermittent scanning was possible due to destruction of the microbubble during scanning. Use of the second generation contrast agent with the low MI technique makes continuous scanning possible. Contrast enhanced US can be used in detection and differentiation of focal liver lesions. It is also helpful for monitoring of radiofrequency ablation and for targeting of US guided biopsy. Currently, because morphologic criteria alone may not reflect the response of the tumor to treatment, new criteria are needed for treatment evaluation after administration of anti-angiogenic agents. Contrast enhanced US could provide quantitative markers for evaluation of the response to treatment via use of dynamic contrast enhanced US. Due to cost-effectiveness, contrast enhanced US is not yet widely used in Korea; however, considering recent issues regarding contrast agent related adverse reaction, such as contrast induced nephropathy and nephrogenic systemic fibrosis, and radiation exposure, contrast enhanced US might be more widely used in Korea, as an alternative imaging modality in the future.

  1. Characterization of nanoparticle-based contrast agents for molecular magnetic resonance imaging

    International Nuclear Information System (INIS)

    Shan, Liang; Chopra, Arvind; Leung, Kam; Eckelman, William C.; Menkens, Anne E.

    2012-01-01

    The development of molecular imaging agents is currently undergoing a dramatic expansion. As of October 2011, ∼4,800 newly developed agents have been synthesized and characterized in vitro and in animal models of human disease. Despite this rapid progress, the transfer of these agents to clinical practice is rather slow. To address this issue, the National Institutes of Health launched the Molecular Imaging and Contrast Agents Database (MICAD) in 2005 to provide freely accessible online information regarding molecular imaging probes and contrast agents for the imaging community. While compiling information regarding imaging agents published in peer-reviewed journals, the MICAD editors have observed that some important information regarding the characterization of a contrast agent is not consistently reported. This makes it difficult for investigators to evaluate and meta-analyze data generated from different studies of imaging agents, especially for the agents based on nanoparticles. This article is intended to serve as a guideline for new investigators for the characterization of preclinical studies performed with nanoparticle-based MRI contrast agents. The common characterization parameters are summarized into seven categories: contrast agent designation, physicochemical properties, magnetic properties, in vitro studies, animal studies, MRI studies, and toxicity. Although no single set of parameters is suitable to define the properties of the various types of contrast agents, it is essential to ensure that these agents meet certain quality control parameters at the preclinical stage, so that they can be used without delay for clinical studies.

  2. High frequency nonlinear scattering from a micrometer to submicrometer sized lipid encapsulated contrast agent

    NARCIS (Netherlands)

    Goertz, David E.; Frijlink, Martijn E.; de Jong, N.; van der Steen, A.F.W.

    2006-01-01

    An experimental lipid encapsulated contrast agent comprised substantially of micrometer to submicrometer diameter bubbles was evaluated for its capacity to produce nonlinear scattering in response to high transmit frequencies. Agent characterization experiments were conducted at transmit frequencies

  3. The use of new contrast media agents in radiology

    International Nuclear Information System (INIS)

    Zerbe, M.

    1992-01-01

    The purpose of the document is to present the importance of different categories of contrast media in radiography. Ionic and non-ionic contrast media are presented. Pharmacology and pathophysiology of Iodine contrast media with their effects on special organs of the body like the heart, vessels, lungs and nervous systems are explained. Paramagnetic contrast media used in NMR imaging are presented too. Emphasis is made on contrast media based on Gadolinium like Gd-DTPA, Gd-CL3, Gd-EDTA. Actions of Gd-DTPA applied to images in urography are pointed out

  4. Contrast enhancement by differently sized paramagnetic MRI contrast agents in mice with two phenotypes of atherosclerotic plaque

    NARCIS (Netherlands)

    van Bochove, Glenda S.; Paulis, Leonie E. M.; Segers, Dolf; Mulder, Willem J. M.; Krams, Rob; Nicolay, Klaas; Strijkers, Gustav J.

    2011-01-01

    Interest in the use of contrast-enhanced MRI to enable in vivo specific characterization of atherosclerotic plaques is increasing. In this study the intrinsic ability of three differently sized gadolinium-based contrast agents to permeate different mouse plaque phenotypes was evaluated with MRI. A

  5. In vivo Photoacoustic Imaging of Prostate Cancer Using Targeted Contrast Agent

    Science.gov (United States)

    2016-11-01

    AD______________ AWARD NUMBER: W81XWH-14-1-0242 TITLE: In Vivo Photoacoustic Imaging of Prostate Cancer Using Targeted Contrast Agent PRINCIPAL...TITLE AND SUBTITLE In vivo Photoacoustic Imaging of Prostate Cancer Using T argeted Contrast Agent 5a. CONTRACT NUMBER W81XWH-14-1-0242 5b. GRANT...diagnose prostate cancer based on the near-infrared optical absorption of either endogenous tissue constituents or exogenous contrast agents . Although

  6. [Utilization of polymeric micelle magnetic resonance imaging (MRI) contrast agent for theranostic system].

    Science.gov (United States)

    Shiraishi, Kouichi

    2013-01-01

    We applied a polymeric micelle carrier system for the targeting of a magnetic resonance imaging (MRI) contrast agent. Prepared polymeric micelle MRI contrast agent exhibited a long circulation characteristic in blood, and considerable amount of the contrast agent was found to accumulate in colon 26 solid tumor by the EPR effect. The signal intensities of tumor area showed 2-folds increase in T1-weighted images at 24 h after i.v. injection. To observe enhancement of the EPR effect by Cderiv pretreatment on tumor targeting, we used the contrast agent for the evaluation by means of MRI. Cderiv pretreatment significantly enhanced tumor accumulation of the contrast agent. Interestingly, very high signal intensity in tumor region was found at 24 h after the contrast agent injection in Cderiv pretreated mice. The contrast agent visualized a microenvironmental change in tumor. These results indicate that the contrast agent exhibits potential use for tumor diagnostic agent. To combine with a polymeric micelle carrier system for therapeutic agent, the usage of the combination makes a new concept of "theranostic" for a better cancer treatment.

  7. Effect of microbubble ligation to cells on ultrasound signal enhancement: implications for targeted imaging.

    Science.gov (United States)

    Lankford, Miles; Behm, Carolyn Z; Yeh, James; Klibanov, Alexander L; Robinson, Peter; Lindner, Jonathan R

    2006-10-01

    Molecular imaging with contrast-enhanced ultrasound (CEU) relies on the detection of microbubbles retained in regions of disease. The aim of this study was to determine whether microbubble attachment to cells influences their acoustic signal generation and stability. Biotinylated microbubbles were attached to streptavidin-coated plates to derive density versus intensity relations during low- and high-power imaging. To assess damping from microbubble attachment to solid or cell surfaces, in vitro imaging was performed for microbubbles charge-coupled to methacrylate spheres and for vascular cell adhesion molecule-1-targeted microbubbles attached to endothelial cells. Signal enhancement on plates increased according to acoustic power and microbubble site density up to 300 mm. Microbubble signal was reduced by attachment to solid spheres during high- and low-power imaging but was minimally reduced by attachment to endothelial cells and only at low power. Attachment of targeted microbubbles to rigid surfaces results in damping and a reduction of their acoustic signal, which is not seen when microbubbles are attached to cells. A reliable concentration versus intensity relationship can be expected from microbubble attachment to 2-dimensional surfaces until a very high site density is reached.

  8. Contrast enhanced MRA: do contrast agents with a higher T1 relaxitivity improve the visualization of carotid artery stenoses?

    International Nuclear Information System (INIS)

    Friese, S.; Krapf, H.; Skalej, M.; Kueker, W.; Fetter, M.; Vonthein, R.

    2001-01-01

    CE-MRA is a powerful tool for the non-invasive evaluation of carotid artery occlusive disease. However, due to certain drawbacks, it has not completely replaced DSA. The purpose of this study was to evaluate if Gd-BOPTA, a contrast agent with high T 1 relaxivity, can increase the diagnostic accuracy of CE-MRA. Material and Methods: The CE-MRA examinations of 54 consecutive patients were evaluated by two experienced radiologists, independently. The examinations of 27 patients were contrasted either with 20 ml Gd-BOPTA or with 20 ml Gd-DTPA. The reviewers were blinded to the contrast agent chosen and to the ultrasound results. They rated the overall image quality and the degree of the ICA stenoses. Results: For the estimation of the degree of the ICA stenoses there was a high interrater validity. In comparison to the ultrasound findings, 6 of 50 high-degree stenoses were underestimated as moderate stenoses. In one of seven sonographically occluded vessels, MRA revealed residual patency in the vessel lumen. It was not possible to identify the contrast agent that was taken for a study. Subjective estimation of the image quality (arterial contrast of the ICA, contrast of the other vessels, and general impression) did not significantly change with the contrast agent employed. Conclusion: The diagnostic accuracy of CE-MRA for the evaluation of internal carotid artery stenoses is not improved by Gd-BOPTA if identical volumina of contrast media are applied. The potential of this contrast agent can be the reduction of the amount of contrast without loss of diagnostic information. Further studies are necessary. (orig.) [de

  9. Contrast-enhanced CT with a High-Affinity Cationic Contrast Agent for Imaging ex Vivo Bovine, Intact ex Vivo Rabbit, and in Vivo Rabbit Cartilage

    OpenAIRE

    Stewart, Rachel C.; Bansal, Prashant N.; Entezari, Vahid; Lusic, Hrvoje; Nazarian, Rosalynn M.; Snyder, Brian D.; Grinstaff, Mark W.

    2013-01-01

    The high affinity of a cationic iodinated contrast agent for cartilage provides better tissue visualization, easier segmentation, higher contrast-to-noise ratios, and longer usable imaging windows and requires a lower dose of injected contrast agent compared with an anionic contrast agent.

  10. Clinical utility of a microbubble-enhancing contrast (“SonoVue”) in treatment of uterine fibroids with high intensity focused ultrasound: A retrospective study

    International Nuclear Information System (INIS)

    Peng, Song; Xiong, Yu; Li, Kequan; He, Min; Deng, Yongbin; Chen, Li; Zou, Min; Chen, Wenzhi; Wang, Zhibiao; He, Jia

    2012-01-01

    Purpose: To evaluate the clinical value of the contrast agent SonoVue in the treatment of uterine fibroids with ultrasound-guided high intensity focused ultrasound (HIFU) therapeutic ablation. Materials and Methods: A total of 291 patients with solitary uterine fibroid from three centers were treated with ultrasound-guided HIFU. Among them, 129 patients from Suining Central Hospital of Sichuan were treated without using SonoVue. 162 patients from the First Hospital of Chongqing Medical University and Chongqing Haifu Hospital were treated with using SonoVue before, during and after HIFU procedure to assess the extent of HIFU. Results: The non-perfused volume (indicative of successful ablation) was observed in all treated uterine fibroids immediately after HIFU ablation; median fractional ablation, defined as non-perfused volume divided by the fibroid volume immediately after HIFU treatment, was 86.0% (range, 28.8–100.0%) in the group with using SonoVue, and 83.0% (8.7–100.0%) without SonoVue. The rate of massive gray scale changes was higher with SonoVue than without the agent. The sonication time to achieve massive gray scale changes was shorter with SonoVue than without. The sonication time for ablating 1 cm 3 of fibroid volume was significantly shorter with using SonoVue than without. No major complications were observed in any patients. Conclusions: Based on our results, SonoVue may enhance the outcome of HIFU ablation and can be used to assess the extent of treatment.

  11. Intravenous carbon dioxide as an echocardiographic contrast agent

    NARCIS (Netherlands)

    R.S. Meltzer (Richard); P.W.J.C. Serruys (Patrick); P.G. Hugenholtz (Paul); J.R.T.C. Roelandt (Jos)

    1981-01-01

    textabstractIntravenous carbon dioxide (CO2) was employed to cause echocardiographic contrast in 40 patients. One to 3 cc of medically pure CO2 were agitated with 5 to 8 cc of 5% dextrose in water and rapidly injected into an upper extremity vein. Contrast was obtained in all patients. In 33

  12. Comparison of differently viscous iodinated and bariumcontaining contrast agents in the detection of pharyngeal perforation

    International Nuclear Information System (INIS)

    Keberle, M.; Wittenberg, G.; Trusen, A.; Hahn, D.; Baumgartner, W.

    2001-01-01

    Purpose: In contrast to esophageal perforations, the more radiopaque barium-suspensions are not as important as iodinated aqueous contrast agents for the detection of pharyngeal perforations. This study was performed to find out whether the highly different viscosities (of iodinated and barium-containing contrast agents with comparable radiopacities) are a reason for this. Methods: Viscosity, subjective difference in contrast, and CT-density of an iodinated aqueous (Telebrix) and a 50 wt/vol% barium-containing contrast agent (Micropaque) were determined. Moreover, to exclude postoperative perforation, 104 patients were prospectively examined by pharyngography using both contrast media. Pharyngographies of patients with perforation were later compared by two independent readers. All patients with perforation were followed up clinically to exclude complications due to barium administration. Results: In-vitro comparison showed comparable radiopacity but the 50 wt/vol% barium-suspension was much more viscous that the iodinated contrast agent. During pharyngography, totally, 14 perforations were clearly delineated with the iodinated aqueous contrast agent. However, two of them were not detected with the barium-suspension. All the other perforations presented equally. Conclusions: Given a sufficient radiopacity, a low viscosity appears to be essential for a contrast agent to detect especially pharyngeal perforations. Thus, we recommend the sole use of an iodinated contrast agent (at suspicion of aspiration as isoosmolar variant) for this purpose. (orig.) [de

  13. Ablation of benign prostatic hyperplasia using microbubble-mediated ultrasound cavitation.

    Science.gov (United States)

    Li, Tao; Liu, Zheng

    2010-04-01

    Benign prostatic hyperplasia (BPH) is a world-wide common disease in elderly male patients. A number of invasive physiotherapies have been used to replace prostatectomy. In this article we report our hypothesis of using microbubbles-mediated ultrasound cavitation effects to ablate prostatic tissues. Microbubble ultrasound contrast agent is widely used contrast media in ultrasonography, yet it is also found to act as cavitation nuclei or enhancer. Once excited by a high peak pressure ultrasound pulse, the mechanical effects, like shock wave and microstream, released from cavitation could produce a series of bioeffects, contributing to sonoporation, microvascular rupture and hematoma. BPH is known to have hyperplastic neovasculature and this make it possible to be disrupted by the physical effects of cavitation under existing microbubbles in circulation. Mechanical ablation of prostatic capillary or small vessels could result in pathological alterations such as thrombosis, micro-circulation blockage, prostatic necrosis and atrophia. Thereupon it could effectively treat BPH by nontraumatic ways. (c) 2009 Elsevier Ltd. All rights reserved.

  14. Engineering of Nanoscale Contrast Agents for Optical Coherence Tomography.

    Science.gov (United States)

    Gordon, Andrew Y; Jayagopal, Ashwath

    2014-01-30

    Optical coherence tomography has emerged as valuable imaging modalityin ophthalmology and other fields by enabling high-resolution three-dimensional imaging of tissue. In this paper, we review recent progress in the field of contrast-enhanced optical coherence tomography (OCT). We discuss exogenous and endogenous sources of OCT contrast, focusing on their use with standard OCT systems as well as emerging OCT-based imaging modalities. We include advances in the processing of OCT data that generate improved tissue contrast, including spectroscopic OCT (SOCT), as well as work utilizing secondary light sources and/or detection mechanisms to create and detect enhanced contrast, including photothermal OCT (PTOCT) and photoacoustic OCT (PAOCT). Finally, we conclude with a discussion of the translational potential of these developments as well as barriers to their clinical use.

  15. An experimental study on tissue reaction of various contrast agents on endometrium, tuber mucosa, and peritoneum

    International Nuclear Information System (INIS)

    Kim, Jae Seung; Kim, Seung Hyup; Park, In Ae; Park, Jae Hyung; Yoon, Dae Young; Yeon, Kyung Mo

    1994-01-01

    To compare the tissue reactions of various water-soluble and oil-based contrast agents on the endometrium, salpingeal mumosa, and peritoneum. Thirty-three rabbits were used for evaluating the histologic reactions of uterine endometrium, salpinx, and peritoneum. Hysterosalpingography(HSG) was underwent in these rabbits by used Lipiodol, Hexabrix, Rayvist. Ultravist-300, Ultravist-370, and normal saline. Pathologic results were obtained in each of the six groups from the uterine endometrium, salpingeal mucosa, and peritoneum without knowledge of the contrast agent used and time interval from HSG. Mild inflammations were observed in the endometrium, salpingeal mucosa, and peritoneum during the first week of HSG in all rabbits in which water-soluble contrast agents were used. Although there was no significant difference in the degree of inflammation among the groups using various contrast agents, the group with oil-based contrast agent(Lipiodol) showed delayed absorption of contrast agent in the peritoneum, frequent intravasation, fat granuloma, peritoneal adhesion, or uterine infarction. Our results suggest that water-soluble contrast agents can be used safely for HSG, but the use of oil-based contrast agent is questional in safety and should be avoid in patients with tubal obstruction, salpingitis, or endometritis

  16. Prevention of radiographic-contrast-agent-induced reductions in renal function by acetylcysteine

    DEFF Research Database (Denmark)

    Tepel, Martin; van der Giet, M; Schwarzfeld, C

    2000-01-01

    Radiographic contrast agents can cause a reduction in renal function that may be due to reactive oxygen species. Whether the reduction can be prevented by the administration of antioxidants is unknown.......Radiographic contrast agents can cause a reduction in renal function that may be due to reactive oxygen species. Whether the reduction can be prevented by the administration of antioxidants is unknown....

  17. Ultrasound contrast-agent improves imaging of lower limb occlusive disease

    DEFF Research Database (Denmark)

    Eiberg, J P; Hansen, M A; Jensen, F

    2003-01-01

    to evaluate if ultrasound contrast-agent infusion could improve duplex-ultrasound imaging of peripheral arterial disease (PAD) and increase the agreement with digital subtraction arteriography (DSA).......to evaluate if ultrasound contrast-agent infusion could improve duplex-ultrasound imaging of peripheral arterial disease (PAD) and increase the agreement with digital subtraction arteriography (DSA)....

  18. Synthetic Ni3S2/Ni hybrid architectures as potential contrast agents in MRI

    International Nuclear Information System (INIS)

    Ma, J; Chen, K

    2016-01-01

    Traditional magnetic resonance imaging (MRI) contrast agents mainly include superparamagnetic (SPM) iron oxide nanoparticle as T 2 contrast agent for liver and paramagnetic Gd (III)-chelate as T 1 contrast agent for all organs. In this work, weak ferromagnetic kale-like and SPM cabbage-like Ni 3 S 2 @Ni hybrid architectures were synthesized and evaluated as potential T 1 MRI contrast agents. Their relatively small r 2 /r 1 ratios of 2.59 and 2.38, and high r 1 values of 11.27 and 4.89 mmol −1 L s −1 (for the kale-like and cabbage-like Ni 3 S 2 @Ni, respectively) will shed some light on the development of new-type MRI contrast agents. (paper)

  19. The 'humble' bubble: Contrast-enhanced ultrasound

    International Nuclear Information System (INIS)

    Marshall, Gill; Sykes, Anne; Berry, Jonathan; Jonker, Leon

    2011-01-01

    The use of contrast-enhanced ultrasound (CEUS) is increasing within the field of medical imaging. Ultrasonic contrast agent (UCA) contain gas microbubbles similar in size to red corpuscles which provide highly reflective interfaces, enabling dynamic demonstration of echogenic streams of the contrast within the anatomical area of interest on real-time grey scale ultrasound. Longevity of the microbubbles has been improved by changing their composition. The application of CEUS in the UK continues to grow, bringing it into territories historically occupied by computerised tomography (CT) scanning and magnetic resonance imaging (MRI). Hence, the role of CEUS may be of interest to all diagnostic imaging practitioners. Here we summarise the mode of action and use of CEUS, and its role within a range of applications. The potential risks of CEUS are compared to other contrast-enhanced imaging techniques. The benefits of CEUS and its implications for diagnostic imaging practice are also covered.

  20. Influence of hyperosmotic agent (glycerol) in contrast enhancement

    International Nuclear Information System (INIS)

    Moriyama, Takashi; Suzuki, Shigeharu; Nakaoka, Tsutomu

    1981-01-01

    For getting a better contrast enhancement (CE) of computed tomography (CT) in brain tumors, we tried to increase the extravascular iodine concentration. A vailing ourselves of the period of returning water following intravenously administered glycerol, a drip injection of the contrast medium gave a better CE effect than the usual CE. In two benign gliomas, CE with glycerol was much better than CE without glycerol, and in two malignant gliomas and two metastatic tumors, CE with glycerol was better, but not so much better as with the benign tumors. In general, the CE effect in primary brain tumors showed a decreasing pattern, whereas in metastatic brain tumors the best time was 60 minutes after the injection of the contrast material (increasing and decreasing pattern), suggesting an increase in the extravascular iodine and a severe failure of the blood brain barrier. Two cystic malignant gliomas allowed the intravenously injected contrast medium to enter the cysts. It appears that the contrast medium passes through and/or is secreted from the wall of the cyst. (author)

  1. Noninvasive visualization of in vivo release and intratumoral distribution of surrogate MR contrast agent using the dual MR contrast technique.

    Science.gov (United States)

    Onuki, Yoshinori; Jacobs, Igor; Artemov, Dmitri; Kato, Yoshinori

    2010-09-01

    A direct evaluation of the in vivo release profile of drugs from carriers is a clinical demand in drug delivery systems, because drug release characterized in vitro correlates poorly with in vivo release. The purpose of this study is to demonstrate the in vivo applicability of the dual MR contrast technique as a useful tool for noninvasive monitoring of the stability and the release profile of drug carriers, by visualizing in vivo release of the encapsulated surrogate MR contrast agent from carriers and its subsequent intratumoral distribution profile. The important aspect of this technique is that it incorporates both positive and negative contrast agents within a single carrier. GdDTPA, superparamagnetic iron oxide nanoparticles, and 5-fluorouracil were encapsulated in nano- and microspheres composed of poly(D,L-lactide-co-glycolide), which was used as a model carrier. In vivo studies were performed with orthotopic xenograft of human breast cancer. The MR-based technique demonstrated here has enabled visualization of the delivery of carriers, and release and intratumoral distribution of the encapsulated positive contrast agent. This study demonstrated proof-of-principle results for the noninvasive monitoring of in vivo release and distribution profiles of MR contrast agents, and thus, this technique will make a great contribution to the field. Copyright (c) 2010 Elsevier Ltd. All rights reserved.

  2. Utility decay rates of T1-weighted magnetic resonance imaging contrast based on redox-sensitive paramagnetic nitroxyl contrast agents

    International Nuclear Information System (INIS)

    Matsumoto, Ken-ichiro

    2009-01-01

    The availability and applicability of the combination of paramagnetic nitroxyl contrast agent and T 1 -weighted gradient echo (GE)-based dynamic magnetic resonance imaging (MRI) measurement for redox imaging are described. The time courses of T 1 -weighted GE MRI signal intensities according to first-order paramagnetic loss of a nitroxyl contrast agent were simulated for several experimental conditions. The apparent decay rate calculated based on decreasing T 1 -weighted MRI contrast (k MRI ) can show an approximate value of the original decay rate (k true ) discretionarily given for simulation with suitable experimental parameters. The difference between k MRI and k true can be sufficiently small under T 1 -weighted spoiled gradient echo (SPGR) scan conditions (repetition time=75 ms, echo time=3 ms, and flip angle=45deg), with a conventional redox-sensitive nitroxyl contrast agent, such as 4-hydroxy-2,2,6,6,-tetramethylpiperidine-N-oxyl (TEMPOL) and/or 3-carbamoyl-2,2,5,5-tetramethylpyrrolidine-N-oxyl (carbamoyl-PROXYL), and with intravenous (i.v.) doses of below 1.5 γmol/g body weight (b.w.) for mice. The results of this simulation suggest that the k MRI of nitroxyl contrast agents can be the primary index of redox status under biological conditions. (author)

  3. Strategies for sensing neurotransmitters with responsive MRI contrast agents.

    Science.gov (United States)

    Angelovski, Goran; Tóth, Éva

    2017-01-23

    A great deal of research involving multidisciplinary approaches is currently dedicated to the understanding of brain function. The complexity of physiological processes that underlie neural activity is the greatest hurdle to faster advances. Among imaging techniques, MRI has great potential to enable mapping of neural events with excellent specificity, spatiotemporal resolution and unlimited tissue penetration depth. To this end, molecular imaging approaches using neurotransmitter-sensitive MRI agents have appeared recently to study neuronal activity, along with the first successful in vivo MRI studies. Here, we review the pioneering steps in the development of molecular MRI methods that could allow functional imaging of the brain by sensing the neurotransmitter activity directly. We provide a brief overview of other imaging and analytical methods to detect neurotransmitter activity, and describe the approaches to sense neurotransmitters by means of molecular MRI agents. Based on these initial steps, further progress in probe chemistry and the emergence of innovative imaging methods to directly monitor neurotransmitters can be envisaged.

  4. Opportunities for new CT contrast agents to maximize the diagnostic potential of emerging spectral CT technologies.

    Science.gov (United States)

    Yeh, Benjamin M; FitzGerald, Paul F; Edic, Peter M; Lambert, Jack W; Colborn, Robert E; Marino, Michael E; Evans, Paul M; Roberts, Jeannette C; Wang, Zhen J; Wong, Margaret J; Bonitatibus, Peter J

    2017-04-01

    The introduction of spectral CT imaging in the form of fast clinical dual-energy CT enabled contrast material to be differentiated from other radiodense materials, improved lesion detection in contrast-enhanced scans, and changed the way that existing iodine and barium contrast materials are used in clinical practice. More profoundly, spectral CT can differentiate between individual contrast materials that have different reporter elements such that high-resolution CT imaging of multiple contrast agents can be obtained in a single pass of the CT scanner. These spectral CT capabilities would be even more impactful with the development of contrast materials designed to complement the existing clinical iodine- and barium-based agents. New biocompatible high-atomic number contrast materials with different biodistribution and X-ray attenuation properties than existing agents will expand the diagnostic power of spectral CT imaging without penalties in radiation dose or scan time. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Synthesis and characterization of a smart contrast agent sensitive to calcium.

    Science.gov (United States)

    Dhingra, Kirti; Maier, Martin E; Beyerlein, Michael; Angelovski, Goran; Logothetis, Nikos K

    2008-08-07

    A novel first-generation Ca2+ sensitive contrast agent, Gd-DOPTRA has been synthesized and characterized. The agent shows approximately 100% relaxivity enhancement upon addition of Ca2+. The agent is selective and sensitive to Ca2+ also in the presence of Mg2+ and Zn2+. The relaxivity studies carried out in physiological fluids prove the prospects of the agent for in vivo measurements.

  6. Nanodiamond-Manganese dual mode MRI contrast agents for enhanced liver tumor detection.

    Science.gov (United States)

    Hou, Weixin; Toh, Tan Boon; Abdullah, Lissa Nurrul; Yvonne, Tay Wei Zheng; Lee, Kuan J; Guenther, Ilonka; Chow, Edward Kai-Hua

    2017-04-01

    Contrast agent-enhanced magnetic resonance (MR) imaging is critical for the diagnosis and monitoring of a number of diseases, including cancer. Certain clinical applications, including the detection of liver tumors, rely on both T1 and T2-weighted images even though contrast agent-enhanced MR imaging is not always reliable. Thus, there is a need for improved dual mode contrast agents with enhanced sensitivity. We report the development of a nanodiamond-manganese dual mode contrast agent that enhanced both T1 and T2-weighted MR imaging. Conjugation of manganese to nanodiamonds resulted in improved longitudinal and transverse relaxivity efficacy over unmodified MnCl 2 as well as clinical contrast agents. Following intravenous administration, nanodiamond-manganese complexes outperformed current clinical contrast agents in an orthotopic liver cancer mouse model while also reducing blood serum concentration of toxic free Mn 2+ ions. Thus, nanodiamond-manganese complexes may serve as more effective dual mode MRI contrast agent, particularly in cancer. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. Design and Optimization of Gadolinium Based Contrast Agents for Magnetic Resonance Imaging

    International Nuclear Information System (INIS)

    Pereira, G.A.; Geraldes, C.F.G.C.; University of Coimbra

    2007-01-01

    The role of Gd 3+ chelates as contrast agents in Magnetic Resonance Imaging is discussed. The theory describing the different contributions to paramagnetic relaxation relevant to the understanding of the molecular parameters determining the relativity of those Gd 3+ chelates, is presented. The experimental techniques used to obtain those parameters are also described. Then, the various approaches taken to optimize those parameters, leading to maximum relativity (efficiency) of the contrast agents, are also illustrated with relevant examples taken from the literature. The various types of Gd 3+ -based agents, besides non-specific and hepatobiliary agents, are also discussed, namely blood pool, targeting, responsive and paramagnetic chemical shift saturation transfer (PARACEST) agents. Finally, a perspective is presented of some of the challenges lying ahead in the optimization of MRI contrast agents to be useful in Molecular Imaging. (author)

  8. A functionalized superparamagnetic iron oxide colloid as a receptor directed MR contrast agent

    International Nuclear Information System (INIS)

    Josephson, L.; Groman, E.V.; Menz, E.; Lewis, J.M.; Bengele, H.

    1990-01-01

    We have synthesized a surface functionalized superparamagnetic iron oxide colloid whose clearance from the vascular compartment was inhibited by asialofetuin but not fetuin. Unlike other particulate or colloidal magnetic resonance (MR) contrast agents, the agent of the current communication is not withdrawn from the vascular compartment by cells of the macrophage-monocyte phagocytic system, as indicated by its selective increase in hepatic relaxation rates. Because of this we refer to this colloid as a hepatic selective (HS) MR contrast agent. At 20 mumol Fe/kg the HS MR agent darkened MR images of liver. The HS MR agent exhibited no acute toxicity when injected into rats at 1800 mumol Fe/kg. Based on these observations, surface functionalized superparamagnetic iron oxide colloids may be the basis of MR contrast agents internalized by receptor mediated endocytosis generally, and by the asialoglycoprotein receptor in particular

  9. 10% low density corn-oil emulsion oral contrast agent for abdominal computed tomography

    International Nuclear Information System (INIS)

    Choi, Sun Kyou; Chon, Dong Kwon; Han, Young Min; Kim, Chong Soo; Sohn, Myung Hee; Song, Ho Young; Choi, Ki Chul

    1990-01-01

    CT of the gastrointestinal tract is commonly performed after administration of a high-density diluted iodinated oral contrast material. However, because if inadequate mixing of the contrast material with the gastrointestinal contents, pseudotumor and poor mucosal visualization are frequently shown on abdominal CT. To overcome these problem, 10% corn oil emulsion (COE) is tested as an alternative oral contrast agent in 40 patients. We analyse patients tolerance, gastric mucosal visualization and discrimination of pancreas from the duodenal C-loop to 10% COE in 40 patients compared with those obtained from 35 patients, who was received high-density diluted iodinated oral contrast agent (gastrografin). The results are as follows : 1. Patients' tolerance to 10% COE is similar to that to conventional oral contrast agent. 2. Image of the gastric mucosa from patients receiving 10% COE is superior to that receiving oral contrast agent. 3. The discrimination between pancreatic head from duodenal C-loop is better in patients receiving 10% COE than in patients receiving conventional oral contrast agent. 4. In patients receiving 10% COE, differentiation of cystic masses from intestinal loops is sometimes difficult. The results of this study indicate that 10% COE may be useful oral contrast agent for optimal visualization of gastric mucosa and pancreatico-duodenal discrimination on abdominal CT

  10. Combined blood pool and extracellular contrast agents for pediatric and young adult cardiovascular magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Joyce T. [Ann and Robert Lurie Children' s Hospital of Chicago, Division of Pediatric Cardiology, 225 E. Chicago Ave., Box 21, Chicago, IL (United States); Ann and Robert Lurie Children' s Hospital of Chicago, Department of Pediatrics, Chicago, IL (United States); Robinson, Joshua D. [Ann and Robert Lurie Children' s Hospital of Chicago, Division of Pediatric Cardiology, 225 E. Chicago Ave., Box 21, Chicago, IL (United States); Ann and Robert Lurie Children' s Hospital of Chicago, Department of Pediatrics, Chicago, IL (United States); Northwestern University, Department of Radiology, Feinberg School of Medicine, Chicago, IL (United States); Deng, Jie [Northwestern University, Department of Radiology, Feinberg School of Medicine, Chicago, IL (United States); Ann and Robert Lurie Children' s Hospital of Chicago, Department of Medical Imaging, Chicago, IL (United States); Rigsby, Cynthia K. [Ann and Robert Lurie Children' s Hospital of Chicago, Department of Pediatrics, Chicago, IL (United States); Northwestern University, Department of Radiology, Feinberg School of Medicine, Chicago, IL (United States); Ann and Robert Lurie Children' s Hospital of Chicago, Department of Medical Imaging, Chicago, IL (United States)

    2016-12-15

    A comprehensive cardiac magnetic resonance (cardiac MR) study including both late gadolinium enhancement (LGE) and MR angiography may be indicated for patients with a history of acquired or congenital heart disease. To study the novel use of an extracellular agent for assessment of LGE combined with a blood pool contrast agent for detailed MR angiography evaluation to yield a comprehensive cardiac MR study in these patients. We reviewed clinical cardiac MR studies utilizing extracellular and blood pool contrast agents and noted demographics, clinical data and adverse events. We rated LGE image quality and MR angiography image quality for each vascular segment and calculated inter-rater variability. We also quantified contrast-to-noise ratio (CNR). Thirty-three patients (mean age 13.9 ± 3 years) received an extracellular contrast agent (10 gadobenate dimeglumine, 23 gadopentetate dimeglumine) and blood pool contrast agent (33 gadofosveset trisodium). No adverse events were reported. MRI indications included Kawasaki disease (8), cardiomyopathy and coronary anatomy (15), repaired congenital heart disease (8), and other (2). Mean LGE quality was 2.6 ± 0.6 with 97% diagnostic imaging. LGE quality did not vary by type of contrast agent given (P = 0.07). Mean MR angiography quality score was 4.7 ± 0.6, with high inter-rater agreement (k = 0.6-0.8, P < 0.002). MR angiography quality did not vary by type of contrast agent used (P = 0.6). Cardiac MR studies utilizing both extracellular and blood pool contrast agents are feasible and safe and provide excellent-quality LGE and MR angiography images. The use of two contrast agents allows for a comprehensive assessment of both myocardial viability and vascular anatomy during the same exam. (orig.)

  11. Combined blood pool and extracellular contrast agents for pediatric and young adult cardiovascular magnetic resonance imaging

    International Nuclear Information System (INIS)

    Johnson, Joyce T.; Robinson, Joshua D.; Deng, Jie; Rigsby, Cynthia K.

    2016-01-01

    A comprehensive cardiac magnetic resonance (cardiac MR) study including both late gadolinium enhancement (LGE) and MR angiography may be indicated for patients with a history of acquired or congenital heart disease. To study the novel use of an extracellular agent for assessment of LGE combined with a blood pool contrast agent for detailed MR angiography evaluation to yield a comprehensive cardiac MR study in these patients. We reviewed clinical cardiac MR studies utilizing extracellular and blood pool contrast agents and noted demographics, clinical data and adverse events. We rated LGE image quality and MR angiography image quality for each vascular segment and calculated inter-rater variability. We also quantified contrast-to-noise ratio (CNR). Thirty-three patients (mean age 13.9 ± 3 years) received an extracellular contrast agent (10 gadobenate dimeglumine, 23 gadopentetate dimeglumine) and blood pool contrast agent (33 gadofosveset trisodium). No adverse events were reported. MRI indications included Kawasaki disease (8), cardiomyopathy and coronary anatomy (15), repaired congenital heart disease (8), and other (2). Mean LGE quality was 2.6 ± 0.6 with 97% diagnostic imaging. LGE quality did not vary by type of contrast agent given (P = 0.07). Mean MR angiography quality score was 4.7 ± 0.6, with high inter-rater agreement (k = 0.6-0.8, P < 0.002). MR angiography quality did not vary by type of contrast agent used (P = 0.6). Cardiac MR studies utilizing both extracellular and blood pool contrast agents are feasible and safe and provide excellent-quality LGE and MR angiography images. The use of two contrast agents allows for a comprehensive assessment of both myocardial viability and vascular anatomy during the same exam. (orig.)

  12. Lung surfactant microbubbles increase lipophilic drug payload for ultrasound-targeted delivery.

    Science.gov (United States)

    Sirsi, Shashank R; Fung, Chinpong; Garg, Sumit; Tianning, Mary Y; Mountford, Paul A; Borden, Mark A

    2013-01-01

    The cavitation response of circulating microbubbles to targeted ultrasound can be used for noninvasive, site-specific delivery of shell-loaded materials. One challenge for microbubble-mediated delivery of lipophilic compounds is the limitation of drug loading into the microbubble shell, which is commonly a single phospholipid monolayer. In this study, we investigated the use of natural lung surfactant extract (Survanta(®), Abbott Nutrition) as a microbubble shell material in order to improve drug payload and delivery. Pulmonary surfactant extracts such as Survanta contain hydrophobic surfactant proteins (SP-B and SP-C) that facilitate lipid folding and retention on lipid monolayers. Here, we show that Survanta-based microbubbles exhibit wrinkles in bright-field microscopy and increased lipid retention on the microbubble surface in the form of surface-associated aggregates observed with fluorescence microscopy. The payload of a model lipophilic drug (DiO), measured by flow cytometry, increased by over 2-fold compared to lipid-coated microbubbles lacking SP-B and SP-C. Lung surfactant microbubbles were highly echogenic to contrast enhanced ultrasound imaging at low acoustic intensities. At higher ultrasound intensity, excess lipid was observed to be acoustically cleaved for localized release. To demonstrate targeting, a biotinylated lipopolymer was incorporated into the shell, and the microbubbles were subjected to a sequence of radiation force and fragmentation pulses as they passed through an avidinated hollow fiber. Lung surfactant microbubbles showed a 3-fold increase in targeted deposition of the model fluorescent drug compared to lipid-only microbubbles. Our results demonstrate that lung surfactant microbubbles maintain the acoustic responsiveness of lipid-coated microbubbles with the added benefit of increased lipophilic drug payload.

  13. Iron Oxide as an Mri Contrast Agent for Cell Tracking: Supplementary Issue

    Directory of Open Access Journals (Sweden)

    Daniel J. Korchinski

    2015-01-01

    Full Text Available Iron oxide contrast agents have been combined with magnetic resonance imaging for cell tracking. In this review, we discuss coating properties and provide an overview of ex vivo and in vivo labeling of different cell types, including stem cells, red blood cells, and monocytes/macrophages. Furthermore, we provide examples of applications of cell tracking with iron contrast agents in stroke, multiple sclerosis, cancer, arteriovenous malformations, and aortic and cerebral aneurysms. Attempts at quantifying iron oxide concentrations and other vascular properties are examined. We advise on designing studies using iron contrast agents including methods for validation.

  14. Magnetic nanoparticles as contrast agents for molecular imaging in medicine

    Science.gov (United States)

    O'Donnell, Matthew

    2018-05-01

    For over twenty years, superparamagnetic nanoparticles have been developed for a number of medical applications ranging from bioseparations, magnetic drug targeting, hyperthermia and imaging. Recent studies have shown that they can be functionalized for in vivo biological targeting, potentially enabling nanoagents for molecular imaging and site-localized drug delivery. Here we review several imaging technologies developed using functionalized superparamagnetic iron oxide nanoparticles (SPIONs) as targeted molecular agents. Several imaging modalities have exploited the large induced magnetic moment of SPIONs to create local mechanical force. Magnetic force microscopy can probe nanoparticle uptake in single cells. For in vivo applications, magnetomotive modulation of primary images in ultrasound (US), photoacoustics (PA), and optical coherence tomography (OCT) can help identify very small concentrations of nanoagents while simultaneously suppressing intrinsic background signals from tissue.

  15. Gd-DTPA as a paramagnetic contrast agent in MR imaging of focal liver lesions

    International Nuclear Information System (INIS)

    Hamm, B.; Roemer, T.; Wolf, K.J.; Felix, R.; Weinmann, H.J.

    1986-01-01

    Gd-DTPA enhances signal intensity in healthy liver and in intrahepatic tumors. However, after contrast agent administration, tumor enhances significantly more than liver parenchyma (2α≤ 0.05). Doubling the dose of Gd-DTPA from 0.1 to 0.2 mmol/kg of body weight increases the enhancement of intrahepatic tumors (2α≤ 0.05) and optimizes the contrast between tumor and liver in T1-weighted spin-echo sequences. However, the contrast between tumor and liver on inversion-recovery and T2-weighted images obtained before contrast agent administration is much greater than the difference on T1-weighted images obtained after contrast agent administration (2α≤ 0.05). In fast images the contrast between liver and tumor can be markedly improved by administering Gd-DTPA

  16. The effects of water soluble contrast agents on the respiratory tract

    International Nuclear Information System (INIS)

    Lovett, I.; Donchey, S.; Doust, B.; Branson, J.; Munro, V.

    1989-01-01

    The water soluble contrast agents Gastrografin R (Sodium diatrizoate and meglumine diatrizoate, Schering, Berlin), Iopamiro 300 R (Iopamidol, Schering, Berlin), and Dionosil Aqueous R (propyliodone BP, Glaxo, England) were instilled into the tracheobronchial tree of rats in doses of either 0.1 ml and 0.25 ml. Rats being used as controls, underwent sham operations with the instillation of air instead of contrast agent. In all, 85 rats were used. All rats that had not already died from the effects of contrast agent were sacrificed 30 minutes after instillation. The relative effects of the contrast agents were measured by comparing: survival time; radiographic effects of the contrast agents on the lungs; and pathological changes as estimated by post mortem lung section and microscopy. The least toxic agent was the one with the lowest osmotic activity, namely Aqueous Dionosil. It is therefore recommended that Aqueous Dionosil be used in preference to Gastrografin or Iopamidol for studies of the oesophagus whenever there is a danger of aspiration of contrast agent into the tracheobronchial tree. 11 refs., 3 figs., 5 tabs

  17. Macromolecular contrast agents for MR mammography: current status

    International Nuclear Information System (INIS)

    Daldrup-Link, Heike E.; Brasch, Robert C.

    2003-01-01

    Macromolecular contrast media (MMCM) encompass a new class of diagnostic drugs that can be applied with dynamic MRI to extract both physiologic and morphologic information in breast lesions. Kinetic analysis of dynamic MMCM-enhanced MR data in breast tumor patients provides useful estimates of tumor blood volume and microvascular permeability, typically increased in cancer. These tumor characteristics can be applied to differentiate benign from malignant lesions, to define the angiogenesis status of cancers, and to monitor tumor response to therapy. The most immediate challenge to the development of MMCM-enhanced mammography is the identification of those candidate compounds that demonstrate the requisite long intravascular distribution and have the high tolerance necessary for clinical use. Potential mammographic applications and limitations of various MMCM, defined by either experimental animal testing or clinical testing in patients, are reviewed in this article. (orig.)

  18. Research on a new oral contrast agent for abdominal MRI using free manganese ion

    International Nuclear Information System (INIS)

    Hasegawa, Hideo; Fujita, Osamu; Hiraishi, Kumiko; Narabayashi, Isamu; Komba, Toshinori; Hamamura, Yoshinori.

    1996-01-01

    Manganese chloride (Mn: 3 mg/100 g) aqueous solution with hydragenated oligosaccharide and xanthan gum (T 1 : 0.1 sec, T 2 : 0.03 sec at 0.5T) functions in gut as a positive contrast agent on MR T 1 -weighted images and a low signal component on MR T 2 -weighted images. The manganese in the solution functions as a contrast agent under free manganese ion (Mn 2+ ). Further, the solution has special characteristics in terms of MRI signal intensity and relaxation time that are equal to those of blueberry juice, which performs as an effective contrast agent on T 1 -and T 2 -weighted images, and functions as a contrast agent in vitro and in vivo. (author)

  19. An MR Contrast Agent for Intra-Prostatic Imaging of Prostatic Cancer

    National Research Council Canada - National Science Library

    Josephson, Lee

    2004-01-01

    The goal of the current research is the development of a magnetic nanoparticle based MR contrast agent that binds the gastrin releasing peptide receptor, a molecular marker associated with neoplasia...

  20. Relaxivity of blood pool contrast agent depends on the host tissue as suggested by semianalytical simulations

    DEFF Research Database (Denmark)

    Jensen, Birgitte Fuglsang; Østergaard, Leif; Kiselev, Valerij G

    Concentration of MRI contrast agents (CA) is commonly determined indirectly using their relaxation effect. In quantitative perfusion studies, the change in the relaxation following a bolus passage is converted into concentrations assuming identical relaxivities for tissue and blood. Simulations...

  1. An MR Contrast Agent for Intra-Prostatic Imaging of Prostatic Cancer

    National Research Council Canada - National Science Library

    Josephson, Lee

    2005-01-01

    An MR contrast agent targeted to the GRP receptor will be a novel pharmaceutical capable of non-invasively, and at high spatial resolution, characterizing healthy and patholological regions within the prostate...

  2. Transthoracic contrast echocardiography using vitamin B6 and sodium bicarbonate as contrast agents for the diagnosis of patent foramen ovale.

    Science.gov (United States)

    He, Jiang-Chun; Zheng, Jian-Yong; Li, Xin; Yang, Ye; Zhang, Bo-Yang; Chen, Yu; Li, Xian-Feng; Liu, Ying-Ming; Cao, Yi; Zhao, Li; Li, Tian-Chang

    2017-08-01

    To evaluate the utility of transthoracic contrast echocardiography (cTTE) using vitamin B6 and sodium bicarbonate as contrast agents for diagnosing right-to-left shunt (RLS) caused by patent foramen ovale (PFO) compared to that of transesophageal echocardiography (TEE). We investigated 125 patients admitted to our neurology department with unexplained cerebral infarction and migraine. All patients underwent cTTE using vitamin B6 and sodium bicarbonate as contrast agents, after which they underwent transthoracic echocardiography. The Doppler signal was recorded during the Valsalva maneuver, and TEE examinations were performed. The feasibility, diagnostic sensitivity, and safety of cTTE and TEE for PFO recognition were compared. Evidence of PFO was found in 49 (39.20%) patients with cTTE, more than were detected with TEE (39, 31.20%) (χ 2 =5.0625, P=0.0244). cTTE had a sensitivity of 92.31% and a specificity of 84.88% for diagnosing PFO, showing high concordance with TEE for PFO recognition (κ=0.72). Further, results of a semi-quantitative evaluation of PFO-RLS by cTTE were better than those with TEE (Z=-2.011, P=0.044). No significant adverse reaction was discovered during cTTE examination. cTTE using vitamin B6 and sodium bicarbonate as contrast agents has relatively good sensitivity and specificity for diagnosing RLS caused by PFO when compared with those for TEE. Using vitamin B6 and sodium bicarbonate as contrast agents to perform cTTE is recommended for detecting and diagnosing the PFO due to its simplicity, non-invasive character, low cost, and high feasibility.

  3. The histopathologic reaction of rabbit lungs after intrabronchial application of contrast agents

    International Nuclear Information System (INIS)

    Lim, Hyo Soon; Kim, Jae Kyu; Shen, Yu Lan; Oh, Jeong Won; Chang, Nam Kyu; Shin, Sang Soo; Park, Jin Gyoon; Kang, Heoung Keun

    2006-01-01

    The aim of this study was to determine a safe gastrointestinal contrast agent that could be used in various clinical situations where there is a risk of aspiration using a rabbit model. 30 healthy white rabbits were used. The rabbits were divided into 5 groups containing six animals each, one control group (anesthesia only) and 4 groups receiving various contrast agents [Solotop (Barium sulphate suspension), Gastrografin (sodium and meglumine amidotrizoate), and Telebrix (Meglumine ioxitalamate), Visipaque (Iodixanol)]. The contrast agents were injected selectively into a main bronchus via a catheter inserted under fluoroscopy guidance. The rabbits were sacrificed either 1 day or 7 days after injecting the contrast agents, and the tissue reaction of the bronchi and lungs were examined both macro-and microscopically. The level of alveolar septal thickening, peribronchiolar lymphocytic infiltration, pulmonary congestion and edema, inflammatory exudate in the alveoli or bronchiolar lumina, microabscess formation, necrosis, pigmentation of materials injected, and fibropurulent pleurisy were evaluated and graded according to the severity as follows: no change, mild, moderate, marked in degree. The common microscopic findings were alveolar septal thickening and peribronchiolar lymphocytic infiltration. Pulmonary congestion and edema, inflammatory exudate in the alveoli of bronchiolar lumina were observed in 21 out of 24 rabbits receiving the contrast agents. Pigmentation of the materials injected was observed only in the group receiving Solotop. An inflammatory exudate in the alveoli and bronchiolar/bronchial lumina, microabscess formation, and necrosis were noted in most groups, but was more frequent and severe in the group receiving Gastrografin. The histopathological reactions of the rabbit lungs after the intrabronchial application of a contrast agent showed variable degrees of inflammatory reaction. Gastrografin produced most severe and extensive reaction, Solotop

  4. The primary applications of Gd-DTPA as an oral negative gastrointestinal contrast agent for MRCP

    International Nuclear Information System (INIS)

    Chen Yanping; Zhang Xuelin; Cheng Guanxun; Chang Renmin; Zhang Yuzhong; Cang Peng; Xia Qiong

    2003-01-01

    Objective: Using oral Gd-DTPA as a negative contrast agent to null the bowel signal during MR cholangiopancreatography (MRCP) to improve the quality of MRCP. Methods: A phantom study was performed to select the optimal concentration of Gd-DTPA to be used as an oral negative contrast agent in MRCP. 15 patients suspected of biliary tract and pancreatic disease were performed with MRCP before and after using 250 ml oral contrast agents (1:5 diluted Gd-DTPA, 1.488 g/L). All MR images were acquired using a 1.5 T whole body MR scanner (Vision Plus, Siemens). MRCP was acquired using two-dimensional single slice fast spin-echo sequence and HASTE (half-fourier acquisition single-shot fast spin echo) sequence. Results: The phantom study showed that the dilution ratio 1:5 of Gd-DTPA oral contrast agent was best in decreasing the signal intensity both in T 2 WI (59.3%) and in HASTE sequence (82.45%). All the dilution ratio of Gd-DTPA oral contrast agent decreased the signal intensity up to 90% on single slice MRCP. In all the patients the high signal intensity from the stomach and intestinal fluid was completely suppressed. The depictions of common bile duct and pancreatic duct were markedly improved by the oral contrast agent (P<0.05). Conclusion: 1:5 diluted (1.488 g/L) oral MR contrast agent Gd-DTPA can be an effective and safe negative contrast agent in eliminating signal intensity of the gastrointestinal tract, thus improving the depiction of the biliary system in MRCP

  5. An algorithm for sensing venous oxygenation using ultrasound-modulated light enhanced by microbubbles

    Science.gov (United States)

    Honeysett, Jack E.; Stride, Eleanor; Deng, Jing; Leung, Terence S.

    2012-02-01

    Near-infrared spectroscopy (NIRS) can provide an estimate of the mean oxygen saturation in tissue. This technique is limited by optical scattering, which reduces the spatial resolution of the measurement, and by absorption, which makes the measurement insensitive to oxygenation changes in larger deep blood vessels relative to that in the superficial tissue. Acousto-optic (AO) techniques which combine focused ultrasound (US) with diffuse light have been shown to improve the spatial resolution as a result of US-modulation of the light signal, however this technique still suffers from low signal-to-noise when detecting a signal from regions of high optical absorption. Combining an US contrast agent with this hybrid technique has been proposed to amplify an AO signal. Microbubbles are a clinical contrast agent used in diagnostic US for their ability to resonate in a sound field: in this work we also make use of their optical scattering properties (modelled using Mie theory). A perturbation Monte Carlo (pMC) model of light transport in a highly absorbing blood vessel containing microbubbles surrounded by tissue is used to calculate the AO signal detected on the top surface of the tissue. An algorithm based on the modified Beer-Lambert law is derived which expresses intravenous oxygen saturation in terms of an AO signal. This is used to determine the oxygen saturation in the blood vessel from a dual wavelength microbubble-contrast AO measurement. Applying this algorithm to the simulation data shows that the venous oxygen saturation is accurately recovered, and this measurement is robust to changes in the oxygenation of the superficial tissue layer.

  6. Submicron polycaprolactone particles as a carrier for imaging contrast agent for in vitro applications.

    Science.gov (United States)

    Iqbal, Muhammad; Robin, Sophie; Humbert, Philippe; Viennet, Céline; Agusti, Geraldine; Fessi, Hatem; Elaissari, Abdelhamid

    2015-12-01

    Fluorescent materials have recently attracted considerable attention due to their unique properties and high performance as imaging agent in biomedical fields. Different imaging agents have been encapsulated in order to restrict its delivery to a specific area. In this study, a fluorescent contrast agent was encapsulated for in vitro application by polycaprolactone (PCL) polymer. The encapsulation was performed using modified double emulsion solvent evaporation technique with sonication. Fluorescent nanoparticles (20 nm) were incorporated in the inner aqueous phase of double emulsion. A number of samples were fabricated using different concentrations of fluorescent contrast agent. The contrast agent-containing submicron particle was characterized by a zetasizer for average particle size, SEM and TEM for morphology observations and fluorescence spectrophotometer for encapsulation efficiency. Moreover, contrast agent distribution in the PCL matrix was determined by confocal microscopy. The incorporation of contrast agent in different concentrations did not affect the physicochemical properties of PCL particles and the average size of encapsulated particles was found to be in the submicron range. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. EPR and DNP Properties of Certain Novel Single Electron Contrast Agents Intended for Oximetric Imaging

    DEFF Research Database (Denmark)

    Ardenkjær-Larsen, J. H.; Laursen, I; Leunbach, I.

    1998-01-01

    Parameters of relevance to oximetry with Overhauser magnetic resonance imaging (OMRI) have been measured for three single electron contrast agents of the triphenylmethyl type. The single electron contrast agents are stable and water soluble. Magnetic resonance properties of the agents have been...... examined with electron paramagnetic resonance (EPR), nuclear magnetic resonance (NMR), and dynamic nuclear polarization (DNP) at 9.5 mT in water, isotonic saline, plasma, and blood at 23 and 37°C. The relaxivities of the agents are about 0.2–0.4 mM−1s−1and the DNP enhancements extrapolate close...... to the dipolar limit. The agents have a single, narrow EPR line, which is analyzed as a Voigt function. The linewidth is measured as a function of the agent concentration and the oxygen concentration. The concentration broadenings are about 1–3 μT/mM and the Lorentzian linewidths at infinite dilution are less...

  8. Application of gold nanoparticles as contrast agents in confocal laser scanning microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Lemelle, A; Veksler, B; Piletsky, S A; Meglinski, I [Cranfield Health, Cranfield University, Cranfield, MK43 0AL (United Kingdom); Kozhevnikov, I S; Akchurin, G G, E-mail: a.lemelle.s06@cranfield.ac.uk [Physics Faculty, Saratov State University, Saratov 410012 (Russian Federation)

    2009-01-15

    Confocal laser scanning microscopy (CLSM) is a modern high-resolution optical technique providing detailed image of tissue structure with high (down to microns) spatial resolution. Aiming at a concurrent improvement of imaging depth and image quality the CLSM requires the use of contrast agents. Commonly employed fluorescent contrast agents, such as fluorescent dyes and proteins, suffer from toxicity, photo-bleaching and overlapping with the tissues autofluorescence. Gold nanoparticles are potentially highly attractive to be applied as a contrast agent since they are not subject to photo-bleaching and can target biochemical cells markers associated with the specific diseases. In current report we consider the applicability of gold nano-spheres as a contrast agent to enhance quality of CLSM images of skin tissues in vitro versus the application of optical clearing agent, such as glycerol. The enhancement of CLSM image contrast was observed with an application of gold nano-spheres diffused within the skin tissues. We show that optical clearing agents such as a glycerol provide better CLSM image contrast than gold nano-spheres.

  9. Application of gold nanoparticles as contrast agents in confocal laser scanning microscopy

    International Nuclear Information System (INIS)

    Lemelle, A; Veksler, B; Piletsky, S A; Meglinski, I; Kozhevnikov, I S; Akchurin, G G

    2009-01-01

    Confocal laser scanning microscopy (CLSM) is a modern high-resolution optical technique providing detailed image of tissue structure with high (down to microns) spatial resolution. Aiming at a concurrent improvement of imaging depth and image quality the CLSM requires the use of contrast agents. Commonly employed fluorescent contrast agents, such as fluorescent dyes and proteins, suffer from toxicity, photo-bleaching and overlapping with the tissues autofluorescence. Gold nanoparticles are potentially highly attractive to be applied as a contrast agent since they are not subject to photo-bleaching and can target biochemical cells markers associated with the specific diseases. In current report we consider the applicability of gold nano-spheres as a contrast agent to enhance quality of CLSM images of skin tissues in vitro versus the application of optical clearing agent, such as glycerol. The enhancement of CLSM image contrast was observed with an application of gold nano-spheres diffused within the skin tissues. We show that optical clearing agents such as a glycerol provide better CLSM image contrast than gold nano-spheres

  10. Application of gold nanoparticles as contrast agents in confocal laser scanning microscopy

    Science.gov (United States)

    Lemelle, A.; Veksler, B.; Kozhevnikov, I. S.; Akchurin, G. G.; Piletsky, S. A.; Meglinski, I.

    2009-01-01

    Confocal laser scanning microscopy (CLSM) is a modern high-resolution optical technique providing detailed image of tissue structure with high (down to microns) spatial resolution. Aiming at a concurrent improvement of imaging depth and image quality the CLSM requires the use of contrast agents. Commonly employed fluorescent contrast agents, such as fluorescent dyes and proteins, suffer from toxicity, photo-bleaching and overlapping with the tissues autofluorescence. Gold nanoparticles are potentially highly attractive to be applied as a contrast agent since they are not subject to photo-bleaching and can target biochemical cells markers associated with the specific diseases. In current report we consider the applicability of gold nano-spheres as a contrast agent to enhance quality of CLSM images of skin tissues in vitro versus the application of optical clearing agent, such as glycerol. The enhancement of CLSM image contrast was observed with an application of gold nano-spheres diffused within the skin tissues. We show that optical clearing agents such as a glycerol provide better CLSM image contrast than gold nano-spheres.

  11. Nonlinear oscillation and interfacial stability of an encapsulated microbubble under dual-frequency ultrasound

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Yunqiao [MOE Key Laboratory of Hydrodynamics, Department of Engineering Mechanics, Shanghai Jiao Tong University, Shanghai 200240 (China); Calvisi, Michael L [Department of Mechanical and Aerospace Engineering, University of Colorado, Colorado Springs, CO 80918, United States of America (United States); Wang, Qianxi, E-mail: yunqiaoliu@sjtu.edu.cn [School of Mathematics, University of Birmingham, Birmingham B15 2TT (United Kingdom)

    2017-04-15

    Encapsulated microbubbles (EMBs) are widely used in medical ultrasound imaging as contrast-enhanced agents. However, the potential damaging effects of violent collapsing EMBs to cells and tissues in clinical settings have remained a concern. Dual-frequency ultrasound is a promising technique for improving the efficacy and safety of sonography. The system modeled consists of the external liquid, membrane and internal gases of an EMB. The microbubble dynamics are simulated using a simple nonlinear interactive theory, considering the compressibility of the internal gas, viscosity of the liquid flow and viscoelasticity of the membrane. The radial oscillation and interfacial stability of an EMB under single- and dual-frequency excitations are compared. The simulation results show that the dual-frequency technique produces larger backscatter pressure at higher harmonics of the primary driving frequency—this enriched acoustic spectrum can enhance blood-tissue contrast and improve the quality of sonographic images. The results further show that the acoustic pressure threshold associated with the onset of shape instability is greater for dual-frequency driving. This suggests that the dual-frequency technique stabilizes the encapsulated bubble, thereby improving the efficacy and safety of contrast-enhanced agents. (paper)

  12. Impact of gadolinium-based contrast agent in the assessment of Crohn's disease activity: Is contrast agent injection necessary?

    Science.gov (United States)

    Quaia, Emilio; Sozzi, Michele; Gennari, Antonio Giulio; Pontello, Michele; Angileri, Roberta; Cova, Maria Assunta

    2016-03-01

    To determine whether magnetic resonance enterography (MRE) performed without intravenous contrast injection is diagnostically noninferior to conventional contrast-enhanced MRE (CE-MRE) in patients with Crohn's disease (CD). This was an Institutional Review Board (IRB)-approved retrospective study. Ninety-six patients (52 male and 44 female; 47.18 years ± 13.6) with a diagnosis of CD underwent MRE at 1.5T including T2 -weighted single-shot turbo-spin-echo, T2 -weighted spectral fat presaturation with inversion recovery (SPAIR), T1 -weighted balanced fast-field-echo MR sequences, and CE-MRE consisting in T1 -weighted breath-hold THRIVE 3D MRI sequences after administration of gadobenate dimeglumine (0.2 mL/kg of body weight). Unenhanced MRE, CE-MRE, and unenhanced MRE plus CE-MRE were reviewed in separate sessions with blinding by two readers in consensus, and subsequently by two other readers independently considering a subgroup of 20 patients. Crohn's Disease Endoscopic Index of Severity (CDEIS) and/or histologic analysis of the surgical specimen were considered as reference standards for the assessment of inflammatory activity. Patients revealed prevalently active (n = 55 patients) or quiescent CD (n = 41 patients). The agreement between unenhanced MRE vs. CE-MRE in interpreting active bowel inflammation was 96% (123/128 bowel segments; one-sided 95% confidence interval [CI], >94.4%). Unenhanced MRE vs. CE-MRE vs. unenhanced MRE plus CE-MRE revealed a diagnostic accuracy of 93% [90/96] vs. 92% [88/96] vs. 97% [93/96] (P > 0.05) in the diagnosis of active CD. Interreader agreement was very good for all variables (κ value = 0.8-0.9) except for the measurement of the length of disease (κ value = 0.45). Unenhanced MRE was noninferior to CE-MRE in diagnosing active inflammation in patients with CD. © 2015 Wiley Periodicals, Inc.

  13. Polymer Assembly Encapsulation of Lanthanide Nanoparticles as Contrast Agents for In Vivo Micro-CT.

    Science.gov (United States)

    Cruje, Charmainne; Dunmore-Buyze, Joy; MacDonald, Jarret P; Holdsworth, David W; Drangova, Maria; Gillies, Elizabeth R

    2018-03-12

    Despite recent technological advancements in microcomputed tomography (micro-CT) and contrast agent development, preclinical contrast agents are still predominantly iodine-based. Higher contrast can be achieved when using elements with higher atomic numbers, such as lanthanides; lanthanides also have X-ray attenuation properties that are ideal for spectral CT. However, the formulation of lanthanide-based contrast agents at the high concentrations required for vascular imaging presents a significant challenge. In this work, we developed an erbium-based contrast agent that meets micro-CT imaging requirements, which include colloidal stability upon redispersion at high concentrations, evasion of rapid renal clearance, and circulation times of tens of minutes in small animals. Through systematic studies with poly(ethylene glycol) (PEG)-poly(propylene glycol), PEG-polycaprolactone, and PEG-poly(l-lactide) (PLA) block copolymers, the amphiphilic block copolymer PEG 114 -PLA 53 was identified to be ideal for encapsulating oleate-coated lanthanide-based nanoparticles for in vivo intravenous administration. We were able to synthesize a contrast agent containing 100 mg/mL of erbium that could be redispersed into colloidally stable particles in saline after lyophilization. Contrast enhancement of over 250 HU was achieved in the blood pool for up to an hour, thereby meeting the requirements of live animal micro-CT.

  14. [Complications due to contrast agent administration: what has been confirmed in prevention?].

    Science.gov (United States)

    Schönenberger, E; Mühler, M; Dewey, M

    2010-12-01

    Computed tomography (CT) and magnetic resonance imaging (MRI) have been evaluated by internists to be the most important medical innovations. Often, intravenous contrast agent administration is required for answering the clinical questions to CT and MRI. In this review we present an overview of the most common and most important aspects that need to be considered prior to intravenous contrast agent administration. We discuss aspects of renal impairment (contrast-induced nephropathy, nephrogenic systemic fibrosis), allergy-like reactions, hyperthyroidism, and pregnancy and breast-feeding.

  15. Elemental imaging of MRI contrast agents: benchmarking of LA-ICP-MS to MRI

    Energy Technology Data Exchange (ETDEWEB)

    Pugh, J.A.T. [University of Sheffield, Centre for Analytical Sciences, Sheffield (United Kingdom); University of Sheffield, Department of Chemical and Biological Engineering, Sheffield (United Kingdom); Cox, A.G.; McLeod, C.W. [University of Sheffield, Centre for Analytical Sciences, Sheffield (United Kingdom); Bunch, J. [University of Birmingham, School of Chemistry, Birmingham (United Kingdom); Writer, M.J.; Hart, S.L. [UCL Institute of Child Health, Wolfson Centre for Gene Therapy of Childhood Disease, London (United Kingdom); Bienemann, A.; White, E. [University of Bristol, School of Clinical Sciences, Southmead Hospital, Bristol (United Kingdom); Bell, J. [Hammersmith Hospital, Metabolic and Molecular Imaging Group, MRC Clinical Sciences Centre, Imperial College London, London (United Kingdom)

    2012-06-15

    Laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) has been used to map the spatial distribution of magnetic resonance imaging (MRI) contrast agents (Gd-based) in histological sections in order to explore synergies with in vivo MRI. Images from respective techniques are presented for two separate studies namely (1) convection enhanced delivery of a Gd nanocomplex (developmental therapeutic) into rat brain and (2) convection enhanced delivery, with co-infusion of Magnevist (commercial Gd contrast agent) and Carboplatin (chemotherapy drug), into pig brain. The LA technique was shown to be a powerful compliment to MRI not only in offering improved sensitivity, spatial resolution and signal quantitation but also in giving added value regarding the fate of administered agents (Gd and Pt agents). Furthermore simultaneous measurement of Fe enabled assignment of an anomalous contrast enhancement region in rat brain to haemorrhage at the infusion site. (orig.)

  16. Superparamagnetic Bifunctional Bisphosphonates Nanoparticles: A Potential MRI Contrast Agent for Osteoporosis Therapy and Diagnostic

    Directory of Open Access Journals (Sweden)

    Y. Lalatonne

    2010-01-01

    Full Text Available A bone targeting nanosystem is reported here which combined magnetic contrast agent for Magnetic Resonance Imaging (MRI and a therapeutic agent (bisphosphonates into one drug delivery system. This new targeting nanoplatform consists of superparamagnetic γFe2O3 nanoparticles conjugated to 1,5-dihydroxy-1,5,5-tris-phosphono-pentyl-phosphonic acid (di-HMBPs molecules with a bisphosphonate function at the outer of the nanoparticle surface for bone targeting. The as-synthesized nanoparticles were evaluated as a specific MRI contrast agent by adsorption study onto hydroxyapatite and MRI measurment. The strong adsorption of the bisphosphonates nanoparticles to hydroxyapatite and their use as MRI T2∗ contrast agent were demonstrated. Cellular tests performed on human osteosarcoma cells (MG63 show that γFe2O3@di-HMBP hybrid nanomaterial has no citoxity effect in cell viability and may act as a diagnostic and therapeutic system.

  17. Non-toxic lead sulfide nanodots as efficient contrast agents for visualizing gastrointestinal tract.

    Science.gov (United States)

    Liu, Zhen; Ran, Xiang; Liu, Jianhua; Du, Yingda; Ren, Jinsong; Qu, Xiaogang

    2016-09-01

    Non-invasive imaging of gastrointestinal (GI) tract using novel but efficient contrast agents is of the most important issues in the diagnosis and prognosis of GI diseases. Here, for the first time, we reported the design and synthesis of biothiol-decorated lead sulfide nanodots, as well as their usages in functional dual-modality imaging of GI tract in vivo. Due to the presence of glutathione on the surface of the nanodots, these well-prepared contrast agents could decrease the unwanted ion leakage, withstand the harsh conditions in GI tract, and avoid the systemic absorption after oral administration. Compared with clinical barium meal and iodine-based contrast agents, these nanodots exhibited much more significant enhancement in contrast efficiency during both 2D X-ray imaging and 3D CT imaging. Different from some conventional invasive imaging modalities, such as gastroscope and enteroscope, non-invasive imaging strategy by using glutathione modified PbS nanodots as contrast agents could reduce the painfulness towards patients, facilitate the imaging procedure, and economize the manipulation period. Moreover, long-term toxicity and bio-distribution of these nanodots after oral administration were evaluated in detail, which indicated their overall safety. Based on our present study, these nanodots could act as admirable contrast agents to integrate X-ray imaging and CT imaging for the direct visualization of GI tract. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. Optimal Contrast Agent Staining of Ligaments and Tendons for X-Ray Computed Tomography.

    Science.gov (United States)

    Balint, Richard; Lowe, Tristan; Shearer, Tom

    2016-01-01

    X-ray computed tomography has become an important tool for studying the microstructures of biological soft tissues, such as ligaments and tendons. Due to the low X-ray attenuation of such tissues, chemical contrast agents are often necessary to enhance contrast during scanning. In this article, the effects of using three different contrast agents--iodine potassium iodide solution, phosphotungstic acid and phosphomolybdic acid--are evaluated and compared. Porcine anterior cruciate ligaments, patellar tendons, medial collateral ligaments and lateral collateral ligaments were used as the basis of the study. Three samples of each of the four ligament/tendon types were each assigned a different contrast agent (giving a total of twelve samples), and the progression of that agent through the tissue was monitored by performing a scan every day for a total period of five days (giving a total of sixty scans). Since the samples were unstained on day one, they had been stained for a total of four days by the time of the final scans. The relative contrast enhancement and tissue deformation were measured. It was observed that the iodine potassium iodide solution penetrated the samples fastest and caused the least sample shrinkage on average (although significant deformation was observed by the time of the final scans), whereas the phosphomolybdic acid caused the greatest sample shrinkage. Equations describing the observed behaviour of the contrast agents, which can be used to predict optimal staining times for ligament and tendon X-ray computed tomography, are presented.

  19. Erbium-Based Perfusion Contrast Agent for Small-Animal Microvessel Imaging

    Directory of Open Access Journals (Sweden)

    Justin J. Tse

    2017-01-01

    Full Text Available Micro-computed tomography (micro-CT facilitates the visualization and quantification of contrast-enhanced microvessels within intact tissue specimens, but conventional preclinical vascular contrast agents may be inadequate near dense tissue (such as bone. Typical lead-based contrast agents do not exhibit optimal X-ray absorption properties when used with X-ray tube potentials below 90 kilo-electron volts (keV. We have developed a high-atomic number lanthanide (erbium contrast agent, with a K-edge at 57.5 keV. This approach optimizes X-ray absorption in the output spectral band of conventional microfocal spot X-ray tubes. Erbium oxide nanoparticles (nominal diameter 4000 Hounsfield units, and perfusion of vessels < 10 μm in diameter was demonstrated in kidney glomeruli. The described new contrast agent facilitated the visualization and quantification of vessel density and microarchitecture, even adjacent to dense bone. Erbium’s K-edge makes this contrast agent ideally suited for both single- and dual-energy micro-CT, expanding potential preclinical research applications in models of musculoskeletal, oncological, cardiovascular, and neurovascular diseases.

  20. Polydisulfide Manganese(II) Complexes as Non-Gadolinium Biodegradable Macromolecular MRI Contrast Agents

    Science.gov (United States)

    Ye, Zhen; Jeong, Eun-Kee; Wu, Xueming; Tan, Mingqian; Yin, Shouyu; Lu, Zheng-Rong

    2011-01-01

    Purpose To develop safe and effective manganese(II) based biodegradable macromolecular MRI contrast agents. Materials and Methods In this study, we synthesized and characterized two polydisulfide manganese(II) complexes, Mn-DTPA cystamine copolymers and Mn-EDTA cystamine copolymers, as new biodegradable macromolecular MRI contrast agents. The contrast enhancement of the two manganese based contrast agents were evaluated in mice bearing MDA-MB-231 human breast carcinoma xenografts, in comparison with MnCl2. Results The T1 and T2 relaxivities were 4.74 and 10.38 mM−1s−1 per manganese at 3T for Mn-DTPA cystamine copolymers (Mn=30.50 kDa) and 6.41 and 9.72 mM−1s−1 for Mn-EDTA cystamine copolymers (Mn= 61.80 kDa). Both polydisulfide Mn(II) complexes showed significant liver, myocardium and tumor enhancement. Conclusion The manganese based polydisulfide contrast agents have a potential to be developed as alternative non-gadolinium contrast agents for MR cancer and myocardium imaging. PMID:22031457

  1. Topical contrast agents to improve soft-tissue contrast in the upper airway using cone beam CT: a pilot study.

    Science.gov (United States)

    Alsufyani, N A; Noga, M L; Finlay, W H; Major, P W

    2013-01-01

    The purpose of this study is to explore the topical use of radiographic contrast agents to enhance soft-tissue contrast on cone beam CT (CBCT) images. Different barium sulphate concentrations were first tested using an airway phantom. Different methods of barium sulphate application (nasal drops, syringe, spray and sinus wash) were then tested on four volunteers, and nebulized iodine was tested in one volunteer. CBCT images were performed and then assessed subjectively by two examiners for contrast agent uniformity and lack of streak artefact. 25.0% barium sulphate presented adequate viscosity and radiodensity. Barium sulphate administered via nasal drops and sprays showed non-uniform collection at the nostrils, along the inferior and/or middle nasal meatuses and posterior nasal choana. The syringe and sinus wash showed similar results with larger volumes collecting in the naso-oropharynx. Nebulized iodine failed to distribute into the nasal cavity and scarcely collected at the nostrils. All methods of nasal application failed to adequately reach or uniformly coat the nasal cavity beyond the inferior nasal meatuses. The key factors to consider for optimum topical radiographic contrast in the nasal airway are particle size, flow velocity and radio-opacity.

  2. Hexabrix (ioxaglate), a new low osmolality contrast agent for lumbar epidural double-catheter venography

    International Nuclear Information System (INIS)

    Meijenhorst, G.C.H.; Bruin, J.N.T. de

    1980-01-01

    Hexabrix (ioxaglate), a new low osmolality contrast agent, has been compared with Telebrix (ioxitalamate) in a series of 50 lumbar epidural venograms. The intensity of the pain and heat sensation experienced by the patient was significantly lower following the injection of Hexabrix. For this reason Hexabrix may be considered the contrast medium of choice for epidural venography. In 15 additional cases Hexabrix was compared with Amipaque (metrizamide) in the same iodine concentration (320 mg/ml). In these patients hardly any difference in pain and heat sensation was observed after the injection of both contrast agents. Frequently only a slight feeling of warmth was noticed. A minimal sensation of pain was occasionally observed to the same degree with both contrast agents. (orig.)

  3. Contrast-enhanced voiding urosonography phantom study: intravenous iodinated and gadolinium-based contrast agents may cause false-negative results in assessment of vesicoureteral reflux in children

    International Nuclear Information System (INIS)

    Veldhoen, Simon; Sauer, Alexander; Gassenmaier, Tobias; Petritsch, Bernhard; Herz, Stefan; Blanke, Philipp; Bley, Thorsten A.; Wirth, Clemens; Derlin, Thorsten

    2015-01-01

    Contrast-enhanced voiding urosonography (ce-VUS) is commonly requested simultaneously to other diagnostic imaging necessitating intravenous contrast agents. To date there is limited knowldedge about intravesical interactions between different types of contrast agents. To assess the effect of excreted intravenous iodinated and gadolinium-based contrast agents on the intravesical distribution of ultrasound contrast within contrast-enhanced voiding urosonography. Iodinated (iomeprol, iopamidol) and gadolinium-based (gadoterate meglumine) contrast agents were diluted to bladder concentration and injected into balloons filled with saline solution. CT scans were performed to assess the contrast distribution in these phantoms. Regions of interest were placed at the top and bottom side of each balloon and Hounsfield units (HU) were measured. Three other balloons were filled with saline solution and contrast media likewise. The ultrasound contrast agent sulphur hexafluoride was added and its distribution was assessed using sonography. MDCT scans showed a separation of two liquid layers in all bladder phantoms with the contrast layers located at the bottom and the saline solution at the top. Significant differences of the HU measurements at the top and bottom side were observed (P < 0.001-0.007). Following injection of ultrasound contrast agent, US showed its distribution exclusively among the saline solution. False-negative results of contrast-enhanced voiding urosonography may occur if it is performed shortly after imaging procedures requiring intravenous contrast. (orig.)

  4. Gadolinium-porphyrins: new potential magnetic resonance imaging contrast agents for melanoma detection

    Directory of Open Access Journals (Sweden)

    Daryoush Shahbazi-Gahrouei

    2006-11-01

    Full Text Available BACKGROUND: Two new porphyrin-based magnetic resonance imaging (MRI contrast agents, Gd-hematoporphyrin (Gd-H and Gd-tetra-carboranylmethoxyphenyl-porphyrin (Gd-TCP were synthesized and tested in nude mice with human melanoma (MM-138 xenografts as new melanoma contrast agents. METHODS: Subcutaneous xenografts of human melanoma cells (MM-138 were studied in 30 (five groups of six nude mice. The effect of different contrast agents (Gd-TCP, Gd-H, GdCl3 and Gd-DTPA on proton relaxation times was measured in tumors and other organs. T1 values, signal enhancement and the Gd concentration for different contrast agent solutions were also investigated. RESULTS: The porphyrin agents showed higher relaxivity compared to the clincal agent, Gd-DTPA. A significant 16% and 21% modification in T1 relaxation time of the water in human melanoma tumors grafted in the nude mice was revealed 24 hours after injection of Gd-TCP and Gd-H, respectively. The percentage of injected Gd localized to the tumor measured by inductively coupled plasma atomic emission spectrometry (ICP-AES was approximately 21% for Gd-TCP and 28% for Gd-H which were higher than that of Gd-DTPA (10%. CONCLUSIONS: The high concentration of Gd in the tumor is indicative of a selective retention of the compounds and indicates that Gd-TCP and Gd-H are promising MR imaging contrast agents for melanoma detection. Gd-porphyrins have considerable promise for further diagnostic applications in magnetic resonance imaging. KEY WORDS: MRI, porphyrin-based contrast agent, hematoporphyrin, melanoma.

  5. Element-specific spectral imaging of multiple contrast agents: a phantom study

    Science.gov (United States)

    Panta, R. K.; Bell, S. T.; Healy, J. L.; Aamir, R.; Bateman, C. J.; Moghiseh, M.; Butler, A. P. H.; Anderson, N. G.

    2018-02-01

    This work demonstrates the feasibility of simultaneous discrimination of multiple contrast agents based on their element-specific and energy-dependent X-ray attenuation properties using a pre-clinical photon-counting spectral CT. We used a photon-counting based pre-clinical spectral CT scanner with four energy thresholds to measure the X-ray attenuation properties of various concentrations of iodine (9, 18 and 36 mg/ml), gadolinium (2, 4 and 8 mg/ml) and gold (2, 4 and 8 mg/ml) based contrast agents, calcium chloride (140 and 280 mg/ml) and water. We evaluated the spectral imaging performances of different energy threshold schemes between 25 to 82 keV at 118 kVp, based on K-factor and signal-to-noise ratio and ranked them. K-factor was defined as the X-ray attenuation in the K-edge containing energy range divided by the X-ray attenuation in the preceding energy range, expressed as a percentage. We evaluated the effectiveness of the optimised energy selection to discriminate all three contrast agents in a phantom of 33 mm diameter. A photon-counting spectral CT using four energy thresholds of 27, 33, 49 and 81 keV at 118 kVp simultaneously discriminated three contrast agents based on iodine, gadolinium and gold at various concentrations using their K-edge and energy-dependent X-ray attenuation features in a single scan. A ranking method to evaluate spectral imaging performance enabled energy thresholds to be optimised to discriminate iodine, gadolinium and gold contrast agents in a single spectral CT scan. Simultaneous discrimination of multiple contrast agents in a single scan is likely to open up new possibilities of improving the accuracy of disease diagnosis by simultaneously imaging multiple bio-markers each labelled with a nano-contrast agent.

  6. Comparison of positive and negative enteral contrast agents for MR imaging of the abdomen

    International Nuclear Information System (INIS)

    Kaminsky, S.; Langer, M.

    1994-01-01

    Following oral administration of a buffered gadopentetate-dimeglumine solution (Magnevist enteral R , 1 mmol/l, 6-17 ml/kg) T 1 -, proton-density- and T 2 -weighted spin-echo images of abdominal and retroperitoneal lesions were acquired (0.5 T). Gadopentetate is a signal-enhancing, positive MR contrast agent, intraluminar air served as a model of a signal-free, negative agent. In 21 patients contrast/noise ratios of gadopentetate and air versus lesions and fat were compared quantitatively (t-test). In T 1 - and T 2 -weighted images contrast/noise ratios of gadopentetate versus lesions were significantly higher than those of air. In proton-density images there was no significant difference. In T 1 - and proton-density images contrast/noise ratios of air versus abdominal fat were significantly higher than those of gadopentetate, in T 2 -weighted images gadopentetate had a significantly higher contrast/noise ratio than air. Signal-enhancing positive contrast agents seem advantageous over signal-free negative enteral MR contrast agents. (orig.) [de

  7. Red blood cell labeling with technetium-99m. Effect of radiopaque contrast agents

    International Nuclear Information System (INIS)

    Finkel, J.; Chervu, L.R.; Bernstein, R.G.; Srivastava, S.C.

    1988-01-01

    Radiographic contrast agents have been reported in the literature to interfere significantly with red blood cell (RBC) labeling in vivo by Tc-99m. Moreover, in the presence of contrast agents, red cells have been known to undergo significant morphologic changes. These observations led to the current RBC labeling study in patients (N = 25) undergoing procedures with the administration of contrast media. Before and after contrast administration, blood samples were drawn from each patient into vacutainer tubes containing heparin and RBC labeling was performed using 1-ml aliquots of these samples following the Brookhaven National Laboratory protocol. The differences in average percentage labeling yield with and without contrast media were not significant. In vivo labeling in hypertensive rats with administration of contrast media up to 600 mg likewise consistently gave high labeling yields at all concentrations. Purported alterations in cell labeling attributed to contrast agents are not reflected in these studies, and other pathophysiologic factors need to be identified to substantiate the previous reports. In vitro study offers a potentially useful and simple method to delineate effects of various agents on cell labeling

  8. Dual-contrast agent photon-counting computed tomography of the heart: initial experience.

    Science.gov (United States)

    Symons, Rolf; Cork, Tyler E; Lakshmanan, Manu N; Evers, Robert; Davies-Venn, Cynthia; Rice, Kelly A; Thomas, Marvin L; Liu, Chia-Ying; Kappler, Steffen; Ulzheimer, Stefan; Sandfort, Veit; Bluemke, David A; Pourmorteza, Amir

    2017-08-01

    To determine the feasibility of dual-contrast agent imaging of the heart using photon-counting detector (PCD) computed tomography (CT) to simultaneously assess both first-pass and late enhancement of the myocardium. An occlusion-reperfusion canine model of myocardial infarction was used. Gadolinium-based contrast was injected 10 min prior to PCD CT. Iodinated contrast was infused immediately prior to PCD CT, thus capturing late gadolinium enhancement as well as first-pass iodine enhancement. Gadolinium and iodine maps were calculated using a linear material decomposition technique and compared to single-energy (conventional) images. PCD images were compared to in vivo and ex vivo magnetic resonance imaging (MRI) and histology. For infarct versus remote myocardium, contrast-to-noise ratio (CNR) was maximal on late enhancement gadolinium maps (CNR 9.0 ± 0.8, 6.6 ± 0.7, and 0.4 ± 0.4, p contrast agent cardiac imaging is feasible with photon-counting detector CT. These initial proof-of-concept results may provide incentives to develop new k-edge contrast agents, to investigate possible interactions between multiple simultaneously administered contrast agents, and to ultimately bring them to clinical practice.

  9. High-Relaxivity MRI Contrast Agents: Where Coordination Chemistry Meets Medical Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Werner, Eric J.; Datta, Ankona; Jocher, Christoph J.; Raymond, Kenneth N.

    2008-01-15

    The desire to improve and expand the scope of clinical magnetic resonance imaging (MRI) has prompted the search for contrast agents of higher efficiency. The development of better agents requires consideration of the fundamental coordination chemistry of the gadolinium(III) ion and the parameters that affect its efficacy as a proton relaxation agent. In optimizing each parameter, other practical issues such as solubility and in vivo toxicity must also be addressed, making the attainment of safe, high-relaxivity agents a challenging goal. Here we present recent advances in the field, with an emphasis on the hydroxypyridinone family of Gd{sup III} chelates.

  10. Use of iohexol as a gastrointestinal contrast agent in three dogs, five cats, and one bird

    International Nuclear Information System (INIS)

    Williams, J.; Biller, D.S.; Myer, C.W.; Miyabayashi, T.; Leveille, R.

    1993-01-01

    Barium sulfate suspension is routinely used as contrast medium for upper gastrointestinal procedures. It has been contraindicated for use in cases of suspected perforation. In such instances, water-soluble iodides are recommended for use. Most of the water-soluble iodides available for use in veterinary medicine at this time are hyperosmolar. This results in in transit dilution of the contrast column. The dilution of the contrast agent within the intestines may prevent visualization of a perforation, especially if the perforation is in the distal portion of the small intestine. Iohexol a nonionic water-soluble iodide of low osmolality, is currently used in veterinary medicine for myelography. We have used it as the contrast agent for upper gastrointestinal studies in cases of suspected obstruction or perforation, with good results, and no adverse effects have been associated with its use. Opacity of the contrast column was adequate, and segmentation or flocculation of the column was not apparent

  11. Evolution of contrast agents for ultrasound imaging and ultrasound-mediated drug delivery

    Directory of Open Access Journals (Sweden)

    Vera ePaefgen

    2015-09-01

    Full Text Available Ultrasound is one of the most frequently used diagnostic methods. It is a non-invasive, comparably inexpensive imaging method with a broad spectrum of applications, which can be increased even more by using bubbles as contrast agents. There are various different types of bubbles: filled with different gases, composed of soft- or hard-shell materials, and ranging in size from nano- to micrometers. These intravascular contrast agents enable functional analyses, e.g. to acquire organ perfusion in real-time. Molecular analyses are achieved by coupling specific ligands to the bubbles’ shell, which bind to marker molecules in the area of interest. Bubbles can also be loaded with or attached to drugs, peptides or genes and can be destroyed by ultrasound pulses to locally release the entrapped agent. Recent studies show that ultrasound contrast agents are also valuable tools in hyperthermia-induced ablation therapy of tumors, or can increase cellular uptake of locally released drugs by enhancing membrane permeability. This review summarizes important steps in the development of ultrasound contrast agents and introduces the current clinical applications of contrast-enhanced ultrasound. Additionally, an overview of the recent developments in ultrasound probe design for functional and molecular diagnosis as well as for drug delivery is given.

  12. Biochemical Stability Analysis of Nano Scaled Contrast Agents Used in Biomolecular Imaging Detection of Tumor Cells

    Science.gov (United States)

    Kim, Jennifer; Kyung, Richard

    Imaging contrast agents are materials used to improve the visibility of internal body structures in the imaging process. Many agents that are used for contrast enhancement are now studied empirically and computationally by researchers. Among various imaging techniques, magnetic resonance imaging (MRI) has become a major diagnostic tool in many clinical specialties due to its non-invasive characteristic and its safeness in regards to ionizing radiation exposure. Recently, researchers have prepared aqueous fullerene nanoparticles using electrochemical methods. In this paper, computational simulations of thermodynamic stabilities of nano scaled contrast agents that can be used in biomolecular imaging detection of tumor cells are presented using nanomaterials such as fluorescent functionalized fullerenes. In addition, the stability and safety of different types of contrast agents composed of metal oxide a, b, and c are tested in the imaging process. Through analysis of the computational simulations, the stabilities of the contrast agents, determined by optimized energies of the conformations, are presented. The resulting numerical data are compared. In addition, Density Functional Theory (DFT) is used in order to model the electron properties of the compound.

  13. Connexin 43-targeted T1 contrast agent for MRI diagnosis of glioma.

    Science.gov (United States)

    Abakumova, Tatiana; Abakumov, Maxim; Shein, Sergey; Chelushkin, Pavel; Bychkov, Dmitry; Mukhin, Vladimir; Yusubalieva, Gaukhar; Grinenko, Nadezhda; Kabanov, Alexander; Nukolova, Natalia; Chekhonin, Vladimir

    2016-01-01

    Glioblastoma multiforme is the most aggressive form of brain tumor. Early and accurate diagnosis of glioma and its borders is an important step for its successful treatment. One of the promising targets for selective visualization of glioma and its margins is connexin 43 (Cx43), which is highly expressed in reactive astrocytes and migrating glioma cells. The purpose of this study was to synthesize a Gd-based contrast agent conjugated with specific antibodies to Cx43 for efficient visualization of glioma C6 in vivo. We have prepared stable nontoxic conjugates of monoclonal antibody to Cx43 and polylysine-DTPA ligands complexed with Gd(III), which are characterized by higher T1 relaxivity (6.5 mM(-1) s(-1) at 7 T) than the commercial agent Magnevist® (3.4 mM(-1) s(-1)). Cellular uptake of Cx43-specific T1 contrast agent in glioma C6 cells was more than four times higher than the nonspecific IgG-contrast agent, as detected by flow cytometry and confocal analysis. MRI experiments showed that the obtained agents could markedly enhance visualization of glioma C6 in vivo after their intravenous administration. Significant accumulation of Cx43-targeted contrast agents in glioma and the peritumoral zone led not only to enhanced contrast but also to improved detection of the tumor periphery. Fluorescence imaging confirmed notable accumulation of Cx43-specific conjugates in the peritumoral zone compared with nonspecific IgG conjugates at 24 h after intravenous injection. All these features of Cx43-targeted contrast agents might be useful for more precise diagnosis of glioma and its borders by MRI. Copyright © 2015 John Wiley & Sons, Ltd.

  14. Investigation of X-ray permeability of surgical gloves coated with different contrast agents

    Science.gov (United States)

    Kayan, Mustafa; Yaşar, Selçuk; Saygın, Mustafa; Yılmaz, Ömer; Aktaş, Aykut Recep; Kayan, Fatmanur; Türker, Yasin; Çetinkaya, Gürsel

    2016-01-01

    Objective: We aimed to investigate the effectiveness and radiation protection capability of latex gloves coated with various contrast agents as an alternative to lead gloves. Methods: The following six groups were created to evaluate the permeability of X-ray in this experimental study: lead gloves, two different non-ionic contrast media (iopromide 370/100 mg I/mL and iomeprol 400/100 mg I/mL), 10% povidone–iodine (PV–I), 240/240 g/mL barium sulphate and a mixture of equal amounts of all contrast agents. A radiation dose detector was placed in coated latex gloves for each one. The absorption values of radiation from latex gloves coated with various contrast agents were measured and compared with the absorption of radiation from lead gloves. This study was designed as an ‘experimental study’. Results: The mean absorption value of X-ray from lead gloves was 3.0±0.08 µG/s. The mean absorption values of X-ray from latex gloves coated with various contrast agents were 3.7±0.09 µG/s (iopromide 370/100 mg I/mL), 3.6±0.09 µG/s (iomeprol 400/100 mg I/mL), 3.7±0.04 µG/s (PV–I), 3.1±0.07 µG/s (barium sulphate) and 3.8±0.05 µG/s (mixture of all contrast agents). Latex gloves coated with barium sulphate provided the best radiation absorption compared with latex gloves coated with other radiodense contrast agents. Conclusion: Latex gloves coated with barium sulphate may provide protection equivalent to lead gloves. PMID:26680548

  15. Diffusion properties of conventional and calcium-sensitive MRI contrast agents in the rat cerebral cortex.

    Science.gov (United States)

    Hagberg, Gisela E; Mamedov, Ilgar; Power, Anthony; Beyerlein, Michael; Merkle, Hellmut; Kiselev, Valerij G; Dhingra, Kirti; Kubìček, Vojtĕch; Angelovski, Goran; Logothetis, Nikos K

    2014-01-01

    Calcium-sensitive MRI contrast agents can only yield quantitative results if the agent concentration in the tissue is known. The agent concentration could be determined by diffusion modeling, if relevant parameters were available. We have established an MRI-based method capable of determining diffusion properties of conventional and calcium-sensitive agents. Simulations and experiments demonstrate that the method is applicable both for conventional contrast agents with a fixed relaxivity value and for calcium-sensitive contrast agents. The full pharmacokinetic time-course of gadolinium concentration estimates was observed by MRI before, during and after intracerebral administration of the agent, and the effective diffusion coefficient D* was determined by voxel-wise fitting of the solution to the diffusion equation. The method yielded whole brain coverage with a high spatial and temporal sampling. The use of two types of MRI sequences for sampling of the diffusion time courses was investigated: Look-Locker-based quantitative T(1) mapping, and T(1) -weighted MRI. The observation times of the proposed MRI method is long (up to 20 h) and consequently the diffusion distances covered are also long (2-4 mm). Despite this difference, the D* values in vivo were in agreement with previous findings using optical measurement techniques, based on observation times of a few minutes. The effective diffusion coefficient determined for the calcium-sensitive contrast agents may be used to determine local tissue concentrations and to design infusion protocols that maintain the agent concentration at a steady state, thereby enabling quantitative sensing of the local calcium concentration. Copyright © 2014 John Wiley & Sons, Ltd.

  16. Quantitative evaluation of contrast agent uptake in standard fat-suppressed dynamic contrast-enhanced MRI examinations of the breast.

    Science.gov (United States)

    Kousi, Evanthia; Smith, Joely; Ledger, Araminta E; Scurr, Erica; Allen, Steven; Wilson, Robin M; O'Flynn, Elizabeth; Pope, Romney J E; Leach, Martin O; Schmidt, Maria A

    2018-01-01

    To propose a method to quantify T 1 and contrast agent uptake in breast dynamic contrast-enhanced (DCE) examinations undertaken with standard clinical fat-suppressed MRI sequences and to demonstrate the proposed approach by comparing the enhancement characteristics of lobular and ductal carcinomas. A standard fat-suppressed DCE of the breast was performed at 1.5 T (Siemens Aera), followed by the acquisition of a proton density (PD)-weighted sequence, also fat suppressed. Both sequences were characterized with test objects (T 1 ranging from 30 ms to 2,400 ms) and calibration curves were obtained to enable T 1 calculation. The reproducibility and accuracy of the calibration curves were also investigated. Healthy volunteers and patients were scanned with Ethics Committee approval. The effect of B 0 field inhomogeneity was assessed in test objects and healthy volunteers. The T 1 of breast tumors was calculated at different time points (pre-, peak-, and post-contrast agent administration) for 20 patients, pre-treatment (10 lobular and 10 ductal carcinomas) and the two cancer types were compared (Wilcoxon rank-sum test). The calibration curves proved to be highly reproducible (coefficient of variation under 10%). T 1 measurements were affected by B 0 field inhomogeneity, but frequency shifts below 50 Hz introduced only 3% change to fat-suppressed T 1 measurements of breast parenchyma in volunteers. The values of T 1 measured pre-, peak-, and post-contrast agent administration demonstrated that the dynamic range of the DCE sequence was correct, that is, image intensity is approximately directly proportional to 1/T 1 for that range. Significant differences were identified in the width of the distributions of the post-contrast T 1 values between lobular and ductal carcinomas (P contrast T 1 values, potentially related to their infiltrative growth pattern. This work has demonstrated the feasibility of fat-suppressed T 1 measurements as a tool for clinical studies. The

  17. Modeling complicated rheological behaviors in encapsulating shells of lipid-coated microbubbles accounting for nonlinear changes of both shell viscosity and elasticity.

    Science.gov (United States)

    Li, Qian; Matula, Thomas J; Tu, Juan; Guo, Xiasheng; Zhang, Dong

    2013-02-21

    It has been accepted that the dynamic responses of ultrasound contrast agent (UCA) microbubbles will be significantly affected by the encapsulating shell properties (e.g., shell elasticity and viscosity). In this work, a new model is proposed to describe the complicated rheological behaviors in an encapsulating shell of UCA microbubbles by applying the nonlinear 'Cross law' to the shell viscous term in the Marmottant model. The proposed new model was verified by fitting the dynamic responses of UCAs measured with either a high-speed optical imaging system or a light scattering system. The comparison results between the measured radius-time curves and the numerical simulations demonstrate that the 'compression-only' behavior of UCAs can be successfully simulated with the new model. Then, the shell elastic and viscous coefficients of SonoVue microbubbles were evaluated based on the new model simulations, and compared to the results obtained from some existing UCA models. The results confirm the capability of the current model for reducing the dependence of bubble shell parameters on the initial bubble radius, which indicates that the current model might be more comprehensive to describe the complex rheological nature (e.g., 'shear-thinning' and 'strain-softening') in encapsulating shells of UCA microbubbles by taking into account the nonlinear changes of both shell elasticity and shell viscosity.

  18. Modeling complicated rheological behaviors in encapsulating shells of lipid-coated microbubbles accounting for nonlinear changes of both shell viscosity and elasticity

    International Nuclear Information System (INIS)

    Li Qian; Tu Juan; Guo Xiasheng; Zhang Dong; Matula, Thomas J

    2013-01-01

    It has been accepted that the dynamic responses of ultrasound contrast agent (UCA) microbubbles will be significantly affected by the encapsulating shell properties (e.g., shell elasticity and viscosity). In this work, a new model is proposed to describe the complicated rheological behaviors in an encapsulating shell of UCA microbubbles by applying the nonlinear ‘Cross law’ to the shell viscous term in the Marmottant model. The proposed new model was verified by fitting the dynamic responses of UCAs measured with either a high-speed optical imaging system or a light scattering system. The comparison results between the measured radius–time curves and the numerical simulations demonstrate that the ‘compression-only’ behavior of UCAs can be successfully simulated with the new model. Then, the shell elastic and viscous coefficients of SonoVue microbubbles were evaluated based on the new model simulations, and compared to the results obtained from some existing UCA models. The results confirm the capability of the current model for reducing the dependence of bubble shell parameters on the initial bubble radius, which indicates that the current model might be more comprehensive to describe the complex rheological nature (e.g., ‘shear-thinning’ and ‘strain-softening’) in encapsulating shells of UCA microbubbles by taking into account the nonlinear changes of both shell elasticity and shell viscosity. (paper)

  19. Assessment of portal venous system patency in the liver transplant candidate: A prospective study comparing ultrasound, microbubble-enhanced colour Doppler ultrasound, with arteriography and surgery

    International Nuclear Information System (INIS)

    Marshall, M.M.; Beese, R.C.; Muiesan, P.; Sarma, D.I.; O'Grady, J.; Sidhu, P.S.

    2002-01-01

    AIM: To determine the role of microbubble-enhanced colour Doppler ultrasound (CDUS) in assessing portal venous patency prior to liver transplantation. MATERIALS AND METHODS: Over a 2-year period, all patients with chronic liver disease undergoing routine pre-transplant CDUS examination in whom the portal venous system was inadequately demonstrated were recruited to the study. CDUS was performed in 368 patients and 33 patients (9%) were recruited. A repeat CDUS examination following an intravenous bolus injection of the microbubble contrast agent Levovist[reg] (Schering Healthcare AG, Berlin, Germany) was performed. Diagnostic confidence was recorded on a free linear analogue scale for both examinations. Findings were compared with indirect portography and surgery. RESULTS: Of the 33 patients with sub-optimal baseline examinations, improvement in portal vein visualization was achieved in 31 patients (94%). Median diagnostic confidence increased from 50% (interquartile range 30-60) to 90% (interquartile range 75-98) (P < 0.001) following administration of Levovist[reg]. Overall accuracy of portal vein assessment using microbubble-enhanced CDUS in 15 patients in whom a definitive diagnosis was made within 2 months was 87%. CONCLUSION: Microbubble-enhanced CDUS is a simple, inexpensive adjunct to standard pre liver transplant screening of the portal vein. It is particularly helpful in patients with end-stage cirrhosis who are at high risk of portal vein thrombosis and in whom the conventional examination is sub-optimal.Marshall, M.M. et al. (2002)

  20. Molecular imaging with targeted contrast ultrasound.

    Science.gov (United States)

    Piedra, Mark; Allroggen, Achim; Lindner, Jonathan R

    2009-01-01

    Molecular imaging with contrast-enhanced ultrasound uses targeted microbubbles that are retained in diseased tissue. The resonant properties of these microbubbles produce acoustic signals in an ultrasound field. The microbubbles are targeted to diseased tissue by using certain chemical constituents in the microbubble shell or by attaching disease-specific ligands such as antibodies to the microbubble. In this review, we discuss the applications of this technique to pathological states in the cerebrovascular system including atherosclerosis, tumor angiogenesis, ischemia, intravascular thrombus, and inflammation. Copyright 2009 S. Karger AG, Basel.

  1. Clinical application of a triombrin in urology, a new Soviet radiographic contrast agent

    International Nuclear Information System (INIS)

    Perel'man, V.M.

    1980-01-01

    A water-soluble radiographic contrast agent triombrin which is a methylglucosamine sodium salt mixture of diatrizoate was studied. The analysis is based on the observation of 175 patients subjected to 186 tests, mainly excretory urography with the double dose of the contrast agent. The correlation between the quality of the picture obtained and the individual features of the patients has been established. Assessment of urograms obtained with the use of hypaque, urografin, verografin, urotrast and triombrin has revealed results similar to those with triombrin. Allergic reactions and complications have been noted in 23 (14%) of 164 patients after excretory and infusion urography. Satisfactory contrast and a good tolerance of the agent allowed recommending triombrin for wide use in medical practice

  2. Forearm Compartment Syndrome of a Newborn Associated with Extravasation of Contrast Agent

    Directory of Open Access Journals (Sweden)

    Egemen Altan

    2013-01-01

    Full Text Available Extravasation of contrast agents is a possible complication of imaging studies. Although extravasations typically cause minimal swelling or erythema, they can lead to compartment syndrome when the volume of extravasation is high. In this article, we will present an exceptional case where an insignificant amount of contrast agent extravasation led to a forearm compartment syndrome in a newborn, who was treated with an extended fasciotomy. We would like to emphasize the preventive techniques and treatment options of this iatrogenic complication in newborns. Close followup of the patient by the nurses, awareness of the parents and the personnel in the radiology department are the most important preventive measures in this extremity-threatening complication. Forearm compartment syndrome due to contrast agent extravasation may progress more rapidly in newborns even with smaller amounts of extravasation and prompt recognition of the pathology and immediate intervention are unevitable.

  3. Diethylenetriaminepentaacetic acid-gadolinium (DTPA-Gd)-conjugated polysuccinimide derivatives as magnetic resonance imaging contrast agents.

    Science.gov (United States)

    Lee, Ha Young; Jee, Hye Won; Seo, Sung Mi; Kwak, Byung Kook; Khang, Gilson; Cho, Sun Hang

    2006-01-01

    Biocompatible polysuccinimide (PSI) derivatives conjugated with diethylenetriaminepentaacetic acid gadolinium (DTPA-Gd) were prepared as magnetic resonance imaging (MRI) contrast agents. In this study, we synthesized PSI derivatives incorporating methoxy-poly(ethylene glycol) (mPEG) as hydrophilic ligand, hexadecylamine as hydrophobic ligand, and DTPA-Gd as contrast agent. PSI was synthesized by the polycondensation polymerization of aspartic acid. All the synthesized materials were characterized by proton nuclear magnetic resonance (1H NMR). Critical micellization concentrations were determined using fluorescent probes (pyrene). Micelle size and shape were measured by electro-photometer light scattering (ELS) and atomic force microscopy (AFM). The formed micelle size ranged from 100 to 300 nm. The T1-weighted MR images of the phantom prepared with PSI-mPEG-C16-(DTPA-Gd) were obtained in a 3.0 T clinical MR imager, and the conjugates showed a great potential as MRI contrast agents.

  4. Contrast agents provide a faster learning curve in dipyridamole stress echocardiography.

    Science.gov (United States)

    Zamorano, Jose; Sánchez, Violeta; Moreno, Raúl; Almería, Carlos; Rodrigo, Jose; Serra, Viviana; Azcona, Luis; Aubele, Adalia; Mataix, Luis; Sánchez-Harguindey, Luis

    2002-12-01

    Interobserver variability is an important limitation of the stress echocardiography and depends on the echocardiographer training. Our aim was to evaluate if the use of contrast agents during dipyridamole stress echocardiography would improve the agreement between an experienced and a non-experienced observer in stress echo and therefore if contrast would affect the learning period of dypyridamole stress echo. Two independent observers without knowledge of any patient data interpreted all stress studies. One observer was an experienced one and the other had experience in echocardiography but not in stress echo. Two observers analysed 87 non-selected and consecutive studies. Out of the 87 studies, 46 were performed without contrast administration, whereas i.v. contrast (2.5 g Levovist by two bolus at rest and at peak stress) was administered in 41. In all cases, second harmonic imaging and stress digitalisation pack was used. The agreement between observers showed a kappa index of 0.58 and 0.83 without and with contrast administration, respectively. The use of contrast agents provides a better agreement in the evaluation of stress echo between an experienced and a non-experienced observer in stress echo. Adding routinely contrast agents could probably reduce the number of exams required for the necessary learning curve in stress echocardiography.

  5. Contrast Agent-Enhanced Computed Tomography of Articular Cartilage: Association with Tissue Composition and Properties

    International Nuclear Information System (INIS)

    Silvast, T. S.; Jurvelin, J.S.; Aula, A.S.; Lammi, M.J.; Toeyraes, J.

    2009-01-01

    Background: Contrast agent-enhanced computed tomography may enable the noninvasive quantification of glycosaminoglycan (GAG) content of articular cartilage. It has been reported that penetration of the negatively charged contrast agent ioxaglate (Hexabrix) increases significantly after enzymatic degradation of GAGs. However, it is not known whether spontaneous degradation of articular cartilage can be quantitatively detected with this technique. Purpose: To investigate the diagnostic potential of contrast agent-enhanced cartilage tomography (CECT) in quantification of GAG concentration in normal and spontaneously degenerated articular cartilage by means of clinical peripheral quantitative computed tomography (pQCT). Material and Methods: In this in vitro study, normal and spontaneously degenerated adult bovine cartilage (n=32) was used. Bovine patellar cartilage samples were immersed in 21 mM contrast agent (Hexabrix) solution for 24 hours at room temperature. After immersion, the samples were scanned with a clinical pQCT instrument. From pQCT images, the contrast agent concentration in superficial as well as in full-thickness cartilage was calculated. Histological and functional integrity of the samples was quantified with histochemical and mechanical reference measurements extracted from our earlier study. Results: Full diffusion of contrast agent into the deep cartilage was found to take over 8 hours. As compared to normal cartilage, a significant increase (11%, P 0.5, P<0.01). Further, pQCT could be used to measure the thickness of patellar cartilage. Conclusion: The present results suggest that CECT can be used to diagnose proteoglycan depletion in spontaneously degenerated articular cartilage with a clinical pQCT scanner. Possibly, the in vivo use of clinical pQCT for CECT arthrography of human joints is feasible

  6. Spectral Imaging Technology-Based Evaluation of Radiation Treatment Planning to Remove Contrast Agent Artifacts.

    Science.gov (United States)

    Yi-Qun, Xu; Wei, Liu; Xin-Ye, Ni

    2016-10-01

    This study employs dual-source computed tomography single-spectrum imaging to evaluate the effects of contrast agent artifact removal and the computational accuracy of radiotherapy treatment planning improvement. The phantom, including the contrast agent, was used in all experiments. The amounts of iodine in the contrast agent were 30, 15, 7.5, and 0.75 g/100 mL. Two images with different energy values were scanned and captured using dual-source computed tomography (80 and 140 kV). To obtain a fused image, 2 groups of images were processed using single-energy spectrum imaging technology. The Pinnacle planning system was used to measure the computed tomography values of the contrast agent and the surrounding phantom tissue. The difference between radiotherapy treatment planning based on 80 kV, 140 kV, and energy spectrum image was analyzed. For the image with high iodine concentration, the quality of the energy spectrum-fused image was the highest, followed by that of the 140-kV image. That of the 80-kV image was the worst. The difference in the radiotherapy treatment results among the 3 models was significant. When the concentration of iodine was 30 g/100 mL and the distance from the contrast agent at the dose measurement point was 1 cm, the deviation values (P) were 5.95% and 2.20% when image treatment planning was based on 80 and 140 kV, respectively. When the concentration of iodine was 15 g/100 mL, deviation values (P) were -2.64% and -1.69%. Dual-source computed tomography single-energy spectral imaging technology can remove contrast agent artifacts to improve the calculated dose accuracy in radiotherapy treatment planning. © The Author(s) 2015.

  7. Nanoparticles in magnetic resonance imaging: from simple to dual contrast agents

    Directory of Open Access Journals (Sweden)

    Estelrich J

    2015-03-01

    Full Text Available Joan Estelrich,1,2 María Jesús Sánchez-Martín,1 Maria Antònia Busquets1,2 1Departament de Fisicoquímica, Facultat de Farmàcia, Universitat de Barcelona, Barcelona, Catalonia, Spain; 2Institut de Nanociència I Nanotecnologia (IN2UB, Barcelona, Catalonia, SpainAbstract: Magnetic resonance imaging (MRI has become one of the most widely used and powerful tools for noninvasive clinical diagnosis owing to its high degree of soft tissue contrast, spatial resolution, and depth of penetration. MRI signal intensity is related to the relaxation times (T1, spin–lattice relaxation and T2, spin–spin relaxation of in vivo water protons. To increase contrast, various inorganic nanoparticles and complexes (the so-called contrast agents are administered prior to the scanning. Shortening T1 and T2 increases the corresponding relaxation rates, 1/T1 and 1/T2, producing hyperintense and hypointense signals respectively in shorter times. Moreover, the signal-to-noise ratio can be improved with the acquisition of a large number of measurements. The contrast agents used are generally based on either iron oxide nanoparticles or ferrites, providing negative contrast in T2-weighted images; or complexes of lanthanide metals (mostly containing gadolinium ions, providing positive contrast in T1-weighted images. Recently, lanthanide complexes have been immobilized in nanostructured materials in order to develop a new class of contrast agents with functions including blood-pool and organ (or tumor targeting. Meanwhile, to overcome the limitations of individual imaging modalities, multimodal imaging techniques have been developed. An important challenge is to design all-in-one contrast agents that can be detected by multimodal techniques. Magnetoliposomes are efficient multimodal contrast agents. They can simultaneously bear both kinds of contrast and can, furthermore, incorporate targeting ligands and chains of polyethylene glycol to enhance the accumulation of

  8. A theranostic dental pulp capping agent with improved MRI and CT contrast and biological properties.

    Science.gov (United States)

    Mastrogiacomo, S; Güvener, N; Dou, W; Alghamdi, H S; Camargo, W A; Cremers, J G O; Borm, P J A; Heerschap, A; Oosterwijk, E; Jansen, J A; Walboomers, X F

    2017-10-15

    Different materials have been used for vital dental pulp treatment. Preferably a pulp capping agent should show appropriate biological performance, excellent handling properties, and a good imaging contrast. These features can be delivered into a single material through the combination of therapeutic and diagnostic agents (i.e. theranostic). Calcium phosphate based composites (CPCs) are potentially ideal candidate for pulp treatment, although poor imaging contrast and poor dentino-inductive properties are limiting their clinical use. In this study, a theranostic dental pulp capping agent was developed. First, imaging properties of the CPC were improved by using a core-shell structured dual contrast agent (csDCA) consisting of superparamagnetic iron oxide (SPIO) and colloidal gold, as MRI and CT contrast agent respectively. Second, biological properties were implemented by using a dentinogenic factor (i.e. bone morphogenetic protein 2, BMP-2). The obtained CPC/csDCA/BMP-2 composite was tested in vivo, as direct pulp capping agent, in a male Habsi goat incisor model. Our outcomes showed no relevant alteration of the handling and mechanical properties (e.g. setting time, injectability, and compressive strength) by the incorporation of csDCA particles. In vivo results proved MRI contrast enhancement up to 7weeks. Incisors treated with BMP-2 showed improved tertiary dentin deposition as well as faster cement degradation as measured by µCT assessment. In conclusion, the presented theranostic agent matches the imaging and regenerative requirements for pulp capping applications. In this study, we combined diagnostic and therapeutic agents in order to developed a theranostic pulp capping agent with enhanced MRI and CT contrast and improved dentin regeneration ability. In our study we cover all the steps from material preparation, mechanical and in vitro characterization, to in vivo study in a goat dental model. To the best of our knowledge, this is the first time that a

  9. Characterization of D-maltose as a T2 -exchange contrast agent for dynamic contrast-enhanced MRI.

    Science.gov (United States)

    Goldenberg, Joshua M; Pagel, Mark D; Cárdenas-Rodríguez, Julio

    2018-09-01

    We sought to investigate the potential of D-maltose, D-sorbitol, and D-mannitol as T 2 exchange magnetic resonance imaging (MRI) contrast agents. We also sought to compare the in vivo pharmacokinetics of D-maltose with D-glucose with dynamic contrast enhancement (DCE) MRI. T 1 and T 2 relaxation time constants of the saccharides were measured using eight pH values and nine concentrations. The effect of echo spacing in a multiecho acquisition sequence used for the T 2 measurement was evaluated for all samples. Finally, performances of D-maltose and D-glucose during T 2 -weighted DCE-MRI were compared in vivo. Estimated T 2 relaxivities (r 2 ) of D-glucose and D-maltose were highly and nonlinearly dependent on pH and echo spacing, reaching their maximum at pH = 7.0 (∼0.08 mM -1 s -1 ). The r 2 values of D-sorbitol and D-mannitol were estimated to be ∼0.02 mM -1 s -1 and were invariant to pH and echo spacing for pH ≤7.0. The change in T 2 in tumor and muscle tissues remained constant after administration of D-maltose, whereas the change in T 2 decreased in tumor and muscle after administration of D-glucose. Therefore, D-maltose has a longer time window for T 2 -weighted DCE-MRI in tumors. We have demonstrated that D-maltose can be used as a T 2 exchange MRI contrast agent. The larger, sustained T 2 -weighted contrast from D-maltose relative to D-glucose has practical advantages for tumor diagnoses during T 2 -weighted DCE-MRI. Magn Reson Med 80:1158-1164, 2018. © 2018 International Society for Magnetic Resonance in Medicine. © 2018 International Society for Magnetic Resonance in Medicine.

  10. Contrast agents and cardiac MR imaging of myocardial ischemia: from bench to bedside

    International Nuclear Information System (INIS)

    Croisille, Pierre; Revel, Didier; Saeed, Maythem

    2006-01-01

    This review paper presents, in the first part, the different classes of contrast media that are already used or are in development for cardiac magnetic resonance imaging. A classification of the different types of contrast media is proposed based on the distribution of the compounds in the body, their type of relaxivity and their potential affinity to particular molecules. In the second part, the different uses of the extracellular type of T1-enhancing contrast agent for myocardial imaging is covered from the detection of stable coronary artery disease to the detection and characterization of chronic infarction. A particular emphasis is placed on the clinical use of gadolinium-chelates, which are the universally used type of MRI contrast agent in the clinical routine. Both approaches, first-pass magnetic resonance imaging (FP-MRI) as well as delayed-enhanced magnetic resonance imaging (DE-MRI), are covered in the different situations of acute and chronic myocardial infarction. (orig.)

  11. Liposomes Loaded with Hydrophobic Iron Oxide Nanoparticles: Suitable T2 Contrast Agents for MRI

    OpenAIRE

    Raquel Martínez-González; Joan Estelrich; Maria Antònia Busquets

    2016-01-01

    There has been a recent surge of interest in the use of superparamagnetic iron oxide nanoparticles (SPIONs) as contrast agents (CAs) for magnetic resonance imaging (MRI), due to their tunable properties and their low toxicity compared with other CAs such as gadolinium. SPIONs exert a strong influence on spin-spin T 2 relaxation times by decreasing the MR signal in the regions to which they are delivered, consequently yielding darker images or negative contrast. Given the potential of these na...

  12. Whole tissue AC susceptibility after superparamagnetic iron oxide contrast agent administration in a rat model

    International Nuclear Information System (INIS)

    Lazaro, Francisco Jose; Gutierrez, Lucia; Rosa Abadia, Ana; Soledad Romero, Maria; Lopez, Antonio; Jesus Munoz, Maria

    2007-01-01

    A magnetic AC susceptibility characterisation of rat tissues after intravenous administration of superparamagnetic iron oxide (Endorem ( R)), at the same dose as established for Magnetic Resonance Imaging (MRI) contrast enhancement in humans, has been carried out. The measurements reveal the presence of the contrast agent as well as that of physiological ferritin in liver and spleen while no traces have been magnetically detected in heart and kidney. This preliminary work opens suggestive possibilities for future biodistribution studies of any type of magnetic carriers

  13. T(2) relaxation time of hyaline cartilage in presence of different gadolinium-based contrast agents.

    Science.gov (United States)

    Wiener, Edzard; Settles, Marcus; Diederichs, Gerd

    2010-01-01

    The transverse relaxation time, T(2), of native cartilage is used to quantify cartilage degradation. T(2) is frequently measured after contrast administration, assuming that the impact of gadolinium-based contrast agents on cartilage T(2) is negligible. To verify this assumption the depth-dependent variation of T(2) in the presence of gadopentetate dimeglumine, gadobenate dimeglumine and gadoteridol was investigated. Furthermore, the r(2)/r(1) relaxivity ratios were quantified in different cartilage layers to demonstrate differences between T(2) and T(1) relaxation effects. Transverse high-spatial-resolution T(1)- and T(2)-maps were simultaneously acquired on a 1.5 T MR scanner before and after contrast administration in nine bovine patellae using a turbo-mixed sequence. The r(2)/r(1) ratios were calculated for each contrast agent in cartilage. Profiles of T(1), T(2) and r(2)/r(1) across cartilage thickness were generated in the absence and presence of contrast agent. The mean values in different cartilage layers were compared for global variance using the Kruskal-Wallis test and pairwise using the Mann-Whitney U-test. T(2) of unenhanced cartilage was 98 +/- 5 ms at 1 mm and 65 +/- 4 ms at 3 mm depth. Eleven hours after contrast administration significant differences (p cartilage thickness were close to 1.0 (range 0.9-1.3). At 1.5 T, T(2) decreased significantly in the presence of contrast agents, more pronounced in superficial than in deep cartilage. The change in T(2) relaxation rate was similar to the change in T(1). Cartilage T(2) measurements after contrast administration will lead to systematic errors in the quantification of cartilage degradation. 2010 John Wiley & Sons, Ltd.

  14. Iron oxide nanoparticles for use in contrast agents in magnetic resonance imaging; Nanoparticulas de oxido de ferro para uso como agentes de contraste em imagens por ressonancia magnetica

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Elisa M.N. de; Rocha, Maximiliano S. da; Caimi, Priscila de A.; Basso, Nara R. de S.; Zanini, Mara L.; Papaleo, Ricardo M., E-mail: elisa.oliveira@acad.pucrs.br [Pontificia Universidade Catolica do Rio Grande do Sul (PUC-RS), Porto Alegre, RS (Brazil)

    2015-07-01

    In this work were carried out synthesis of iron oxide nanoparticles coated with dextran, comparing the results of using different concentrations of dextran, iron salts, temperature and reaction time. The compounds were analyzed by DLS, XRD, TGA, TEM, FTIR, Zeta Potential and relaxivity. Nanoparticles with dispersion around 10-15 nm and average hydrodynamic diameters of 16-50 nm, with superparamagnetic behavior were obtained. The ratio of the relaxivities (r2/r1) in aqueous solutions was 5.30, close to value of the commercially available iron oxide contrast agents. (author)

  15. Measuring SPIO and Gd contrast agent magnetization using 3 T MRI

    Science.gov (United States)

    Cantillon-Murphy, Pádraig; Wald, Lawrence L.; Zahn, Markus; Adalsteinsson, Elfar

    2011-01-01

    Traditional methods of measuring magnetization in magnetic fluid samples, such as vibrating sample magnetometry (VSM), are typically limited to maximum field strengths of about 1 T. This work demonstrates the ability of MRI to measure the magnetization associated with two commercial MRI contrast agents at 3 T by comparing analytical solutions to experimental imaging results for the field pattern associated with agents in cylindrical vials. The results of the VSM and fitted MRI data match closely. The method represents an improvement over VSM measurements since results are attainable at imaging field strengths. The agents investigated are Feridex, a superparamagnetic iron oxide suspension used primarily for liver imaging, and Magnevist, a paramagnetic, gadolinium-based compound used for tumors, inflammation and vascular lesions. MR imaging of the agents took place in sealed cylindrical vials in the presence of a surrounding volume of deionized water where the effects of the contrast agents had a measurable effect on the water's magnetization in the vicinity of the compartment of contrast agent. A pair of phase images were used to reconstruct a B0 fieldmap. The resultant B0 maps in the water region, corrected for shimming and container edge effects, were used to predict the agent's magnetization at 3 T. The results were compared with the results from VSM measurements up to 1.2 T and close correlation was observed. The technique should be of interest to those seeking quantification of the magnetization associated with magnetic suspensions beyond the traditional scope of VSM. The magnetization needs to be sufficiently strong (Ms≳50 Am2/kg Fe for Feridex and χm≳5 × 10−5 m3/kg Gd for Magnevist) for a measurable dipole field in the surrounding water. For this reason, the technique is mostly suitable for undiluted agents. PMID:19588450

  16. Impact of contrast agent viscosity on coronary balloon deflation times: bench testing results.

    Science.gov (United States)

    Mogabgab, Owen; Patel, Vishal G; Michael, Tesfaldet T; Kotsia, Anna; Christopoulos, George; Banerjee, Subhash; Brilakis, Emmanouil S

    2014-04-01

    To assess the impact of viscosity on angioplasty balloon deflation times. Lower contrast viscosity could result in more rapid coronary balloon deflation times. We performed a bench comparison of coronary balloon deflation times using 2 contrast agents with different viscosity (ioxaglate and iodixanol), 3 contrast dilutions, and 2 inflation syringe filling volumes. Ten identical pairs of coronary angioplasty balloons were used to conduct each comparison after balloon inflation to 12 atmospheres. Simultaneous deflations were performed under cineangiography. The time to full contrast extraction and the area of contrast remaining after 5 seconds of deflation (quantified by opaque pixel count) were compared between groups. The mean time to full contrast extraction during balloon deflation was 8.3 ± 2.5 seconds for ioxaglate (lower viscosity) versus 10.1 ± 2.9 seconds for iodixanol (higher viscosity) (17.4% decrease, P = 0.005), with a 35.6% (P = 0.004) reduction in contrast area at 5 seconds. Compared to 1:1 ioxaglate-saline mixture, 1:2 and 1:3 ioxaglate/saline mixes resulted in 26.7% (P deflation time, respectively, but at the expense of decreased balloon opacity. Filling the inflation syringe with 5 versus 15 ml of contrast/saline solution was associated with 7.5% decrease in balloon deflation time (P = 0.005), but no difference in contrast area at 5 seconds (P = 0.749). Use of a lower viscosity contrast agent and higher contrast dilution significantly reduced coronary balloon deflation times, whereas use of lower syringe filling volume had a modest effect. Rapid coronary balloon deflation could improve the safety of interventional procedures. © 2014 Wiley Periodicals, Inc.

  17. Comparison and evaluation of indicator dilution models for bolus of ultrasound contrast agents

    Czech Academy of Sciences Publication Activity Database

    Harabis, V.; Kolář, R.; Mézl, M.; Jiřík, Radovan

    2013-01-01

    Roč. 34, č. 2 (2013), s. 151-162 ISSN 0967-3334 R&D Projects: GA ČR GAP102/12/2380 Institutional support: RVO:68081731 Keywords : perfusion model * ultrasound * contrast agent * intravascular perfusion * tissue phantom Subject RIV: FS - Medical Facilities ; Equipment Impact factor: 1.617, year: 2013

  18. Counterbalancing the use of ultrasound contrast agents by a cavitation-regulated system.

    Science.gov (United States)

    Desjouy, C; Fouqueray, M; Lo, C W; Muleki Seya, P; Lee, J L; Bera, J C; Chen, W S; Inserra, C

    2015-09-01

    The stochastic behavior of cavitation can lead to major problems of initiation and maintenance of cavitation during sonication, responsible of poor reproducibility of US-induced bioeffects in the context of sonoporation for instance. To overcome these disadvantages, the injection of ultrasound contrast agents as cavitation nuclei ensures fast initiation and lower acoustic intensities required for cavitation activity. More recently, regulated-cavitation devices based on the real-time modulation of the applied acoustic intensity have shown their potential to maintain a stable cavitation state during an ultrasonic shot, in continuous or pulsed wave conditions. In this paper is investigated the interest, in terms of cavitation activity, of using such regulated-cavitation device or injecting ultrasound contrast agents in the sonicated medium. When using fixed applied acoustic intensity, results showed that introducing ultrasound contrast agents increases reproducibility of cavitation activity (coefficient of variation 62% and 22% without and with UCA, respectively). Moreover, the use of the regulated-cavitation device ensures a given cavitation activity (coefficient of variation less 0.4% in presence of UCAs or not). This highlights the interest of controlling cavitation over time to free cavitation-based application from the use of UCAs. Interestingly, during a one minute sonication, while ultrasound contrast agents progressively disappear, the regulated-cavitation device counterbalance their destruction to sustain a stable inertial cavitation activity. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Ultrasound-triggered local release of lipophilic drugs from a novel polymeric ultrasound contrast agent

    NARCIS (Netherlands)

    Kooiman, K.; Böhmer, M.R.; Emmer, M.; Vos, Hendrik J.; Chlon, C.; Foppen-Harteveld, M.; Versluis, Michel; de Jong, N.; van Wamel, A.; Hennink, W.E.; Feijen, J.; Sam, A.P.

    2008-01-01

    The advantage of ultrasound contrast agents (UCAs) as drug delivery systems is the ability to non-invasively control the local and triggered release of a drug or gene. In this study we designed and characterized a novel UCA-based drug delivery system, based on polymer-shelled microcapsules filled

  20. A novel MR contrast agent for angiography and perfusion: Hyperpolarized water

    DEFF Research Database (Denmark)

    Lipsø, Hans Kasper Wigh

    , hyperpolarized by dissolution Dynamic Nuclear Polarization (d-DNP), can be applied as an MRI contrast agent for angiography and perfusion. The first part of the project focuses on development of a protocol for production of large samples of hyperpolarized protons in D2O. The samples are polarized and dissolved...

  1. Contrast Agents for Micro-Computed Tomography of Microdamage in Bone

    National Research Council Canada - National Science Library

    Roeder, Ryan K

    2008-01-01

    ...) and contrast agents with higher x-ray attenuation than bone. The ability to detect the presence and to a limited extent the morphology of microdamage in cortical and trabecular bone using micro-CT was demonstrated using a barium sulfate (BaSO4) stain...

  2. Three-dimensional magnetic resonance coronary angiography using a new blood pool contrast agent : Initial experience

    NARCIS (Netherlands)

    Bedaux, WLF; Hofman, MBM; Wielopolski, PA; de Cock, CC; Hoffmann, [No Value; Oudkerk, M; de Feyter, PJ; van Rossum, AC

    2002-01-01

    Objective: The aim of this feasibility study was to assess the effect of a new blood pool contrast agent on magnetic resonance coronary angiography (MRCA) in patients suspected of having coronary artery disease. Methods: Nine patients referred for diagnostic x-ray coronary, angiography in the

  3. Non-invasive estimation of blood pressure using ultrasound contrast agents

    DEFF Research Database (Denmark)

    Andersen, Klaus Scheldrup; Jensen, Jørgen Arendt

    2009-01-01

    Local blood pressure measurements provide important information on the state of health of organs in the body and can be used to diagnose diseases in the heart, lungs, and kidneys. This paper presents an experimental setup for investigating the ambient pressure sensitivity of a contrast agent using...

  4. Non-invasive ambient pressure estimation using non-linear ultrasound contrast agents

    DEFF Research Database (Denmark)

    Andersen, Klaus Scheldrup

    Many attempts to find a non-invasive procedure to measure the blood pressure locally in the body have been made. This dissertation focuses on the approaches which utilize highly compressible ultrasound contrast agents as ambient pressure sensors. The literature within the topic has been reviewed...

  5. Impact of acoustic pressure on ambient pressure estimation using ultrasound contrast agent

    DEFF Research Database (Denmark)

    Andersen, Klaus Scheldrup; Jensen, Jørgen Arendt

    2010-01-01

    Local blood pressure measurements provide important information on the state of health of organs in the body and can be used to diagnose diseases in the heart, lungs, and kidneys. This paper presents an approach for investigating the ambient pressure sensitivity of a contrast agent using diagnostic...

  6. Characterization of Definity™ Ultrasound Contrast Agent at Frequency Range of 5–15 MHz

    NARCIS (Netherlands)

    Faez, Telli; Goertz, David; de Jong, N.

    2011-01-01

    The status of vasa vasorum, which can be imaged using ultrasound contrast agents, is an indication for the progression of atherosclerosis. The preferred ultrasound frequency for this purpose is between 5 and 15 MHz. Therefore, it is essential to have knowledge about the acoustic properties of

  7. Clusters of magnetic nanoparticles as contrast agents for MRI: effect of aggregation on transverse relaxivity

    Czech Academy of Sciences Publication Activity Database

    Dědourková, T.; Kaman, Ondřej; Veverka, Pavel; Koktan, Jakub; Veverka, Miroslav; Kuličková, Jarmila; Jirák, Zdeněk; Herynek, V.

    2015-01-01

    Roč. 51, č. 11 (2015), s. 5300804 ISSN 0018-9464 R&D Projects: GA ČR GA15-10088S; GA MPO FR-TI3/521 Institutional support: RVO:68378271 Keywords : contrast agents * magnetic resonance imaging * magnetic nanoparticles * manganites * transverse relaxivity Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 1.277, year: 2015

  8. Part 1: MRI features of focal nodular hyperplasia with an emphasis on hepatobiliary contrast agents

    International Nuclear Information System (INIS)

    Sutherland, Tom; Seale, Melanie; Yap, Yap

    2014-01-01

    Focal nodular hyperplasia (FNH) is the second most common benign liver tumour and typically do not require any treatment. An accurate non-invasive diagnosis is therefore vital to avoid unnecessary intervention and to reassure patients. This article discusses the demographics and pathology of FNH and reviews the appearance of FNH at MRI using liver-specific contrast agents.

  9. Gd-functionalised Au nanoparticles as targeted contrast agents in MRI: relaxivity enhancement by polyelectrolyte coating.

    Science.gov (United States)

    Warsi, Muhammad Farooq; Adams, Ralph W; Duckett, Simon B; Chechik, Victor

    2010-01-21

    Monolayer-protected, Gd(3+)-functionalised gold nanoparticles with enhanced spin-lattice relaxivity (r(1)) were prepared; adsorption of polyelectrolytes on these materials further increased r(1) and ligand exchange with a biotin-derivatised disulfide led to a prototype avidin-targeted contrast agent.

  10. Modeling Encapsulated Microbubble Dynamics at High Pressure Amplitudes

    Science.gov (United States)

    Heyse, Jan F.; Bose, Sanjeeb; Iaccarino, Gianluca

    2017-11-01

    Encapsulated microbubbles are commonly used in ultrasound contrast imaging and are of growing interest in therapeutic applications where local cavitation creates temporary perforations in cell membranes allowing for enhanced drug delivery. Clinically used microbubbles are encapsulated by a shell commonly consisting of protein, polymer, or phospholipid; the response of these bubbles to externally imposed ultrasound waves is sensitive to the compressibility of the encapsulating shell. Existing models approximate the shell compressibility via an effective surface tension (Marmottant et al. 2005). We present simulations of microbubbles subjected to high amplitude ultrasound waves (on the order of 106 Pa) and compare the results with the experimental measurements of Helfield et al. (2016). Analysis of critical points (corresponding to maximum and minimum expansion) in the governing Rayleigh-Plesset equation is used to make estimates of the parameters used to characterize the effective surface tension of the encapsulating shell. Stanford Graduate Fellowship.

  11. Adverse events caused by MRI contrast agents: Implications for radiographers who inject

    International Nuclear Information System (INIS)

    Marshall, Gill; Kasap, Chris

    2012-01-01

    This article provides a comprehensive literature review regarding side effects both minor and major associated with contrast agent injection. This includes a discussion of nephrogenic systemic fibrosis (NSF), which remains highly topical. Radiographers now commonly are responsible for injection of contrast agent in patients, in keeping with their extended role. Therefore it is incumbent on them to understand the agents they inject, the contra-indications for injection and any potential associated risks, so that they can act and react accordingly in a timely manner. The need for this knowledge was made very evident after the recent death of a patient from anaphylactic shock when there was a delay in mounting the appropriate procedure. This paper represents a synthesis of relevant articles and reflects on the results, before drawing appropriate conclusions particularly those of special relevance to radiographers.

  12. Optical-based molecular imaging: contrast agents and potential medical applications

    International Nuclear Information System (INIS)

    Bremer, Christoph; Ntziachristos, Vasilis; Weissleder, Ralph

    2003-01-01

    Laser- and sensitive charge-coupled device technology together with advanced mathematical modelling of photon propagation in tissue has prompted the development of novel optical imaging technologies. Fast surface-weighted imaging modalities, such as fluorescence reflectance imaging (FRI) and 3D quantitative fluorescence-mediated tomography have now become available [1, 2]. These technical advances are paralleled by a rapid development of a whole range of new optical contrasting strategies, which are designed to generate molecular contrast within a living organism. The combination of both, technical advances of light detection and the refinement of optical contrast media, finally yields a new spectrum of tools for in vivo molecular diagnostics. Whereas the technical aspects of optical imaging are covered in more detail in a previous review article in ''European Radiology'' [3], this article focuses on new developments in optical contrasting strategies and design of optical contrast agents for in vivo diagnostics. (orig.)

  13. In vivo photoacoustic tumor tomography using a quinoline-annulated porphyrin as NIR molecular contrast agent.

    Science.gov (United States)

    Luciano, Michael; Erfanzadeh, Mohsen; Zhou, Feifei; Zhu, Hua; Bornhütter, Tobias; Röder, Beate; Zhu, Quing; Brückner, Christian

    2017-01-25

    The synthesis and photophysical properties of a tetra-PEG-modified and freely water-soluble quinoline-annulated porphyrin are described. We previously demonstrated the ability of quinoline-annulated porphyrins to act as an in vitro NIR photoacoustic imaging (PAI) contrast agent. The solubility of the quinoline-annulated porphyrin derivative in serum now allowed the assessment of the efficacy of the PEGylated derivative as an in vivo NIR contrast agent for the PAI of an implanted tumor in a mouse model. A multi-fold contrast enhancement when compared to the benchmark dye ICG could be shown, a finding that could be traced to its photophysical properties (short triplet lifetimes, low fluorescence and singlet oxygen sensitization quantum yields). A NIR excitation wavelength of 790 nm could be used, fully taking advantage of the optical window of tissue. Rapid renal clearance of the dye was observed. Its straight-forward synthesis, optical properties with the possibility for further optical fine-tuning, nontoxicity, favorable elimination rates, and contrast enhancement make this a promising PAI contrast agent. The ability to conjugate the PAI chromophore with a fluorescent tag using a facile and general conjugation strategy was also demonstrated.

  14. Studies on polyaspartamide gadolinium complexes as potential magnetic resonance imaging contrast agents

    International Nuclear Information System (INIS)

    Yan Guoping; Liu Maili; Li Liyun

    2005-01-01

    Purpose: A series of polyaspartamide gadolinium complexes containing pyridoxamine groups were studied as the potential magnetic resonance imaging (MRI) contrast agents for liver enhancement. Methods: These polyaspartamide gadolinium complexes were prepared and evaluated by relaxivity, acute toxicity studies and magnetic resonance imaging of the liver in rats. Results: These polyaspartamide gadolinium complexes have higher relaxation effectiveness than that of the clinically used gadolinium diethylenetriaminepentaacetic acid and possess the low intravenous acute toxicities to Institute for Cancer Research (ICR) mice. Magnetic resonance imaging of the liver in rats indicated that they greatly enhance the contrast of magnetic resonance images and provide prolonged intravascular duration in the liver. Conclusion: These results indicated that the polyaspartamide gadolinium complexes containing pyridoxamine groups could be considered as the appropriate MRI contrast agents for liver enhancement

  15. Fatal anaphylactic reaction to intravenous gadobutrol, a gadolinium-based MRI contrast agent

    Directory of Open Access Journals (Sweden)

    Sabine Franckenberg, MD

    2018-02-01

    Full Text Available We present the rare case of a fatal anaphylactic reaction to gadobutrol, a magnetic resonance imaging contrast agent, in a 42-year-old man. The patient underwent elective magnetic resonance imaging for diagnostic clarification of a suspicious finding in the abdomen. The patient had undergone contrast-enhanced computed tomography previously without the occurrence of any adverse effects. Adverse drug reactions in gadobutrol have a very low prevalence of 0.32%-3.5%, with serious adverse drug reactions in <0.1%. There are only a few cases of fatal anaphylactoid reactions to gadolinium-based contrast agents in general. However, if an anaphylactoid reaction occurs, it can present itself with a fulminant course within minutes.

  16. Diagnosis of Popliteal Venous Entrapment Syndrome by Magnetic Resonance Imaging Using Blood-Pool Contrast Agents

    International Nuclear Information System (INIS)

    Beitzke, Dietrich; Wolf, Florian; Juelg, Gregor; Lammer, Johannes; Loewe, Christian

    2011-01-01

    Popliteal vascular entrapment syndrome is caused by aberrations or hypertrophy of the gastrocnemius muscles, which compress the neurovascular structures of the popliteal fossa, leading to symptoms of vascular and degeneration as well as aneurysm formation. Imaging of popliteal vascular entrapment may be performed with ultrasound, magnetic resonance imaging (MRI), computed tomography angiography, and conventional angiography. The use of blood-pool contrast agents in MRI when popliteal vascular entrapment is suspected offers the possibility to perform vascular imaging with first-pass magnetic resonance angiographic, high-resolution, steady-state imaging and allows functional tests all within one examination with a single dose of contrast agent. We present imaging findings in a case of symptomatic popliteal vein entrapment diagnosed by the use of blood pool contrast-enhanced MRI.

  17. An albumin-based gold nanocomposites as potential dual mode CT/MRI contrast agent

    Science.gov (United States)

    Zhao, Wenjing; Chen, Lina; Wang, Zhiming; Huang, Yuankui; Jia, Nengqin

    2018-02-01

    In pursuit of the biological detection applications, recent years have witnessed the prosperity of novel multi-modal nanoprobes. In this study, biocompatible bovine serum albumin (BSA)-coated gold nanoparticles (Au NPs) containing Gd (III) as the contrast agent for both X-ray CT and T1-weighted MR imaging is reported. Firstly, the Au NPs with BSA coating (Au@BSA) was prepared through a moderate one-pot reduction route in the presence of hydrazine hydrate as reducer. Sequentially, the BSA coating enables modification of diethylenetriaminepentaacetic acid (DTPA) as well as targeting reagent hyaluronic acid (HA), and further chelation of Gd (III) ions led to the formation of biomimetic nanoagent HA-targeted Gd-Au NPs (HA-targeted Au@BSA-Gd-DTPA). Several techniques were used to thoroughly characterize the formed HA-targeted Gd-Au NPs. As expected, the as-prepared nanoagent with mean diameter of 13.82 nm exhibits not only good colloid stablility and water dispersibility, but also satisfying low cytotoxicity and hemocompatibility in the tested concentration range. Additionally, for the CT phantoms, the obtained nanocomplex shows an improved contrast in CT scanning than that of Au@BSA as well as small molecule iodine-based CT contrast agents such as iopromide. Meanwhile, for the T1-weighted MRI images, there is a linear increase of contrast with concentration of Gd for the two cases of HA-targeted Gd-Au NPs and Magnevist. Strikingly, the nanoagent we explored displays a relatively higher r1 relaxivity than that of commercial MR contrast agents. Therefore, this newly constructed nanoagent could be used as contrast agents for synergistically enhanced X-ray CT and MR phantoms, holding promising potential for future biomedical applications.

  18. Assessment of MRI Contrast Agent Kinetics via Retro-Orbital Injection in Mice: Comparison with Tail Vein Injection.

    Science.gov (United States)

    Wang, Fang; Nojima, Masanori; Inoue, Yusuke; Ohtomo, Kuni; Kiryu, Shigeru

    2015-01-01

    It is not known whether administration of contrast agent via retro-orbital injection or the tail vein route affects the efficiency of dynamic contrast-enhanced magnetic resonance imaging (MRI). Therefore, we compared the effects of retro-orbital and tail vein injection on the kinetics of the contrast agent used for MRI in mice. The same group of nine healthy female mice received contrast agent via either route. An extracellular contrast agent was infused via the tail vein and retro-orbital vein, in random order. Dynamic contrast-enhanced MRI was performed before and after administering the contrast agent. The contrast effects in the liver, kidney, lung, and myocardium were assessed. The average total times of venous puncture and mounting of the injection system were about 10 and 4 min for the tail vein and retro-orbital route, respectively. For all organs assessed, the maximum contrast ratio occurred 30 s after administration and the time course of the contrast ratio was similar with either routes. For each organ, the contrast ratios correlated strongly; the contrast ratios were similar. The retro-orbital and tail vein routes afforded similar results in terms of the kinetics of the contrast agent. The retro-orbital route can be used as a simple efficient alternative to tail vein injection for dynamic contrast-enhanced MRI of mice.

  19. Early detection of osteoarthritis in rabbits using MRI with a double-contrast agent.

    Science.gov (United States)

    Onishi, Okihiro; Ikoma, Kazuya; Kido, Masamitsu; Kabuto, Yukichi; Ueshima, Keiichiro; Matsuda, Ken-Ichi; Tanaka, Masaki; Kubo, Toshikazu

    2018-03-13

    Articular cartilage degeneration has been evaluated by magnetic resonance imaging (MRI). However, this method has several problems, including its time-consuming nature and the requirement of a high magnetic field or specialized hardware. The purpose of this study was to sequentially assess early degenerative changes in rabbit knee articular cartilage using MRI with a new double-contrast agent. We induced osteoarthritis (OA) in the right knee of rabbits by anterior cruciate ligament transection and partial medial meniscectomy. Proton density-weighted images and T 2 -calculated images were obtained before and after contrast agent injection into the knee. The signal intensity ratio (SIR) values on the proton density-weighted images were calculated by dividing the signal intensity of the articular cartilage by that of joint fluid. Six rabbits were examined using MRI at 2 (designated 2-w OA) and 4 weeks (4-w OA) after the operation. Histological examination was performed 4 weeks after the operation. One rabbit was histologically examined 2 weeks after the operation. The control consisted of six rabbits that were not subjected to the operation. The SIR values, T 2 values and the thicknesses of the cartilage of the 2-w OA, 4-w OA and the control before and after contrast agent injection were analyzed. The Mankin score and OARSI (Osteoarthritis Research Society International) score were used for the histological evaluation. Significant differences in the SIR and T 2 values of the medial and lateral condyles of the femur were found between the control and the 4-w OA only after contrast agent injection. No significant differences were found in the SIR and T 2 values before contrast agent injection between the control, the 2-w OA and 4-w OA. The thickness of the articular cartilage revealed no significant differences. In the histological assessment, the Mankin score and OARSI score sequentially increased from the control to the 4-w OA. We evaluated the SIR and T 2 values

  20. Dynamic contrast enhanced ultrasound for therapy monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Hudson, John M. [Department of Medical Biophysics, University of Toronto, Toronto, ON (Canada); Williams, Ross [Imaging Research, Sunnybrook Research Institute, Toronto, ON (Canada); Tremblay-Darveau, Charles; Sheeran, Paul S. [Department of Medical Biophysics, University of Toronto, Toronto, ON (Canada); Milot, Laurent [Department of Medical Imaging, University of Toronto, Toronto, ON (Canada); Bjarnason, Georg A. [Department of Medical Oncology, University of Toronto, and Sunnybrook Odette Cancer Centre, Toronto, ON (Canada); Burns, Peter N., E-mail: burns@sri.utoronto.ca [Department of Medical Biophysics, University of Toronto, Toronto, ON (Canada); Imaging Research, Sunnybrook Research Institute, Toronto, ON (Canada); Department of Medical Imaging, University of Toronto, Toronto, ON (Canada)

    2015-09-15

    Quantitative imaging is a crucial component of the assessment of therapies that target the vasculature of angiogenic or inflamed tissue. Dynamic contrast-enhanced ultrasound (DCE-US) using microbubble contrast offers the advantages of being sensitive to perfusion, non-invasive, cost effective and well suited to repeated use at the bedside. Uniquely, it employs an agent that is truly intravascular. This papers reviews the principles and methodology of DCE-US, especially as applied to anti-angiogenic cancer therapies. Reproducibility is an important attribute of such a monitoring method: results are discussed. More recent technical advances in parametric and 3D DCE-US imaging are also summarised and illustrated.

  1. The use of innovative gadolinium-based contrast agent for MR-diagnosis of cancer in the experiment

    International Nuclear Information System (INIS)

    Chernov, V; Medvedeva, A; Sinilkin, I; Zelchan, R; Grigorev, E; Frolova, I; Nam, I

    2016-01-01

    The present study of the functional suitability and specific activity of the contrast agent gadolinium-based for magnetic resonance imaging demonstrated that the investigated contrast agent intensively accumulates in organs and anatomical structures of the experimental animals. In the model of tumor lesions in animals, study have shown that investigational contrast agent accumulates in the tumor tissue and retained there in for a long enough time. (paper)

  2. Highly stabilized gadolinium chelates functionalized on metal nanoparticles as magnetic resonance imaging contrast agent

    Science.gov (United States)

    Siddiqui, Talha S.

    Magnetic resonance imaging (MRI) is a non-invasive method for imaging and diagnosing tissue damage, organ function and the vascular system. Magnevist(TM) a complex of diethylenetriaminepentaacetic acid (DTPA) and Gd3+ is a clinically approved contrast agent for MRI. A derivative of DTPA was formed by the addition of two cysteine groups (DTPA-L-Cys) through amide linkage. The Gd complex of this ligand bonds with the silver surfaces through the cysteine thiols. GdDTPA-L-Cys was bound to ˜10nm diameter Ag nanoparticles for use as a multifunctional MRI contrast agent. The ligand and complex were characterized by 1H and 13C NMR, ESI-MS and IR spectroscopy. The silver construct was characterized by TEM, TGA and UV-Vis absorption spectra. The per metal complex r1 relaxivity of GdDTPA-L-Cys{Ag} greater than that of Magnavist(TM) with the same molarity for both compounds. The synthesis of a DTPA derivative is described that allows it to bind to silver or gold nanoparticles through a single thiol linkage (DTPASH). The resulting Gd complex, GdDTPASH, was bound to Ag nanoparticles to create a single monolayer on the surface. The construct was further stabilized in buffered solution with the addition of a thiolated PEG chain. The highly stabilized nanoparticle construct delivers a high payload of Gd compelex and is an effective T1 brightening agent. The production of this type of construct opens the way for engineered multimodal MRI contrast agents.

  3. Gd-DTPA: a bowel contrast agent for magnetic resonance imaging of the abdomen

    International Nuclear Information System (INIS)

    Vlahos, L.; Gouliamos, A.; Clauss, W.; Kalovidouris, A.; Hadjiioannou, A.; Athanasopoulou, A.; Trakadas, S.; Papavasiliou, C.

    1992-01-01

    Forty patients with suspected pathology in the abdomen and pelvis have been investigated with MRI before and after administration of Gd-DTPA as an oral or rectal solution. The findings are analysed with respect to: (a) filling of the GI tract; (b) contrast in the region of interest, surrounding fat and vessels; (c) diagnostic yield in comparison to non-enhanced MRI and contrast CT. At a concentration of 1 mmol/l Gd-DTPA provided consistent positive contrast in the stomach and bowel in all cases. In 57.5% of cases we achieved complete filling of the GI tract. The opacification in the region of interest was good or satisfactory in 90% of cases. The diagnostic value of contrast MRI was better in 93% of cases than the non-enhanced MRI of the abdomen. In comparison with contrast CT, the contrast MRI was better or of the same value in 92% of cases. Despite the disadvantage of poor fat-to-bowel contrast (35% of cases were classified as poor), it is concluded that Gd-DTPA-enhanced MRI provides good delineation of organs adjacent to the bowel so this contrast agent has potential for a future role in abdominal MRI. (orig.)

  4. Gd-DTPA: a bowel contrast agent for magnetic resonance imaging of the abdomen

    Energy Technology Data Exchange (ETDEWEB)

    Vlahos, L. [Dept. of Radiology, Univ. of Athens, Areteion Hospital (Greece); Gouliamos, A. [Dept. of Radiology, Univ. of Athens, Areteion Hospital (Greece); Clauss, W. [Schering A. G., Berlin (Germany); Kalovidouris, A. [Dept. of Radiology, Univ. of Athens, Areteion Hospital (Greece); Hadjiioannou, A. [Dept. of Radiology, Univ. of Athens, Areteion Hospital (Greece); Athanasopoulou, A. [Dept. of Radiology, Univ. of Athens, Areteion Hospital (Greece); Trakadas, S. [Dept. of Radiology, Univ. of Athens, Areteion Hospital (Greece); Papavasiliou, C. [Dept. of Radiology, Univ. of Athens, Areteion Hospital (Greece)

    1992-08-01

    Forty patients with suspected pathology in the abdomen and pelvis have been investigated with MRI before and after administration of Gd-DTPA as an oral or rectal solution. The findings are analysed with respect to: (a) filling of the GI tract; (b) contrast in the region of interest, surrounding fat and vessels; (c) diagnostic yield in comparison to non-enhanced MRI and contrast CT. At a concentration of 1 mmol/l Gd-DTPA provided consistent positive contrast in the stomach and bowel in all cases. In 57.5% of cases we achieved complete filling of the GI tract. The opacification in the region of interest was good or satisfactory in 90% of cases. The diagnostic value of contrast MRI was better in 93% of cases than the non-enhanced MRI of the abdomen. In comparison with contrast CT, the contrast MRI was better or of the same value in 92% of cases. Despite the disadvantage of poor fat-to-bowel contrast (35% of cases were classified as poor), it is concluded that Gd-DTPA-enhanced MRI provides good delineation of organs adjacent to the bowel so this contrast agent has potential for a future role in abdominal MRI. (orig.)

  5. An experimental study on tissue reaction of various contrast agents on mediastinum

    International Nuclear Information System (INIS)

    Chung, Jin Wook; Kim, Hyung Jin; Kim, Seung Hyup; Park, Jae Hyung; Chang, Kee Hyun

    1989-01-01

    Till now, there is no consensus about appropriate contrast agents for use in clinical investigation in suspected perforation of the esophagus. Gastrografin, most widely used water soluble contrast agent, is less sensitive in detection of fistulous tract and can induce pulmonary edema, leading to death occasionally, if aspirated. Barium sulphate has been contraindicated without actual evaluation of its effect on mediastinum by experimental and clinical study. The purpose of this experimental study is to evaluate the type of tissue reaction and its severity in mediastinum and, as a result, to propose appropriate contrast agents in various clinical situations of suspected esophageal leakage. Barium sulphate, Hytrat, Gastrografin, Telebrix, Hexabrix, Amipaque, Niopam, and Ultravist were injected into mediastinum of 20 rats in each. The tissue reaction of injection sites were examined microscopically and graded according severity of inflammatory reaction with serial follow up from 1 day to 8 weeks after injection. The results are as follows, 1. Barium sulphate and Hytrast produced highly significant (p<0.01) tissue reaction compared to saline group and early inflammatory reaction was more severe in Hytrast. 2. Water soluble agents produced no significant reaction in mediastinum compared to saline control group and proved to be safe in the situation of leakage into mediastinum. 3. Injected barium caused no death during 8 week follow up in spite of large injected amount and histologically produced localized indolent granuloma after 4 weeks which is expected not to cause any delayed complications. In consideration of above results, superior physical characteristics of barium sulphate and drawbacks of Gastrografin, we concluded as follows. 1. For postoperative assessment of esophageal anastomosis, Barium sulphate is the contrast agent of choice

  6. Complications from the use of intravenous gadolinium-based contrast agents for magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Elias Junior, Jorge; Santos, Antonio Carlos dos; Nogueira-Barbosa, Marcello Henrique; Muglia, Valdair Francisco; Koenigkam-Santos, Marcel [Universidade de Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Hospital das Clinicas. Centro de Ciencias das Imagens e Fisica Medica]. E-mail: jejunior@fmrp.usp.br

    2008-07-15

    Gadolinium-based contrast agents are much safer than the iodinated ones; however complications may occur and should be recognized for appropriate orientation and management. The total incidence of adverse reactions to contrast agents in magnetic resonance imaging ranges between 2% and 4%. Cases of severe acute reactions to gadolinium, such as laryngospasm and anaphylactic shock, are rare. Chronic complications secondary to the use of gadolinium also can occur and, recently an association between its use and a rare dermatologic disease occurring in patients with renal failure has been reported. Nephrogenic systemic fibrosis was the subject of an official health notification issued by the American Food and Drug Administration. This progressive disease is characterized by hardened skin with fibrotic nodules and plaques which may involve other parts of the body. Patients who have been affected by this disorder presented chronic renal failure, with metabolic acidosis and had been submitted to magnetic resonance angiography, probably involving exposure to large amounts of intravenous paramagnetic contrast. This review is aimed at presenting a succinct description of the gadolinium-based contrast agent types, possible secondary complications, their preventive measures and management. (author)

  7. Nephrogenic systemic fibrosis after application of gadolinium-based contrast agents - a status paper

    International Nuclear Information System (INIS)

    Heinrich, M.; Uder, M.

    2007-01-01

    Recently the association of a rare disease named ''nephrogenic systemic fibrosis'' (NSF) with the administration of gadolinium-containing contrast media, especially gadodiamide (Omniscan, GE-Healthcare), was described. NSF is a scleroderma-like disease characterised by widespread tissue fibrosis. Until now, NSF cases were observed only in patients with kidney disease. Almost all patients were suffering from chronic renal insufficiency, 90 % of them required renal replacement therapy. The true incidence of the disease is unknown. First retrospective analyses of selected collectives of patients with end-stage renal disease showed 2 - 5 % cases of NSF after administration of Gadolinium-containing contrast agents with an odds ratio of 20 - 50 in comparison to non-exposed controls. NSF is a serious adverse reaction, which may result in severe disabilities and even death. Therefore all radiologists applying gadolinium-based contrast agents should be informed about this disease and the recent recommendations for its prevention. On the basis of the published data, Omniscan should not be used in patients with severe renal impairment (GFR 2 ) and those who have had or are undergoing liver transplantation. In neonates and infants up to 1 year of age, Omniscan should only be used after careful consideration. Also the other gadolinium-based contrast agents should be used in high-risk patients only after careful consideration using the lowest dose possible

  8. MRI contrast agent for molecular imaging of the HER2/neu receptor using targeted magnetic nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    Rasaneh, Samira; Rajabi, Hossein, E-mail: hrajabi@modares.ac.ir [Tarbiat Modares University, Department of Medical Physics (Iran, Islamic Republic of); Babaei, Mohammad Hossein [Nuclear Science and Technology Research Institute, Department of Radioisotope (Iran, Islamic Republic of); Akhlaghpoor, Shahram [Sina Hospital, Tehran Medical University, Noor Medical Imaging Center (Iran, Islamic Republic of)

    2011-06-15

    In this study, Trastuzumab modified Magnetic Nanoparticles (TMNs) were prepared as a new contrast agent for detecting HER2 (Human epidermal growth factor receptor-2) expression tumors by magnetic resonance imaging (MRI). TMNs were prepared based on iron oxide nanoparticles core and Trastuzumab modified dextran coating. The TMNs core and hydrodynamic size were determined by transmission electron microscopy and dynamic light scattering. TMNs stability and cytotoxicity were investigated. The ability of TMNs for HER2 detection were evaluated in breast carcinoma cell lines (SKBr3 and MCF7 cells) and tumor-bearing mice by MRI and iron uptake determination. The particles core and hydrodynamic size were 9 {+-} 2.5 and 41 {+-} 15 nm (size range: 15-87 nm), respectively. The molar antibody/nanoparticle ratio was 3.1-3.5. TMNs were non-toxic to the cells below the 30 {mu}g (Fe)/mL concentration and good stable up to 8 weeks in PBS buffer. TMNs could detect HER2 oncogenes in the cells surface with imagable contrast by MRI. The invivo study in mice bearing tumors indicated that TMNs possessed a good diagnostic ability as HER2 specific contrast agent by MRI. TMNs were demonstrated to be able to selectively accumulate in the tumor cells, with a proper signal enhancement in MRI T2 images. So, the complex may be considered for further investigations as an MRI contrast agent for detection of HER2 expression tumors in human.

  9. A naturally occurring contrast agent for OCT imaging of smokers' lung

    International Nuclear Information System (INIS)

    Yang Ying; Bagnaninchi, Pierre O; Whiteman, Suzanne C; Pittius, Daniel Gey van; Haj, Alicia J El; Spiteri, Monica A; Wang, Ruikang K

    2005-01-01

    Optical coherence tomography (OCT) offers great potential for clinical applications in terms of its cost, safety and real-time imaging capability. Improvement of its resolution for revealing sub-layers or sub-cellular components within a tissue will further widen its application. In this study we report that carbon pigment, which is frequently present in the lungs of smokers, could be used as a contrast agent to improve the OCT imaging of lung tissue. Carbon produced an intense bright OCT image at a relatively deep location. The parallel histopathological section analysis confirmed the presence of carbon pigment in such tissues. The underlying mechanism of the OCT image formation has been discussed based on a model system in which carbon particles were dispersed in agar gel. Calculations and in-depth intensity profiles of OCT revealed that higher refractive index particles with a size close to or smaller than the wavelength would greatly increase backscattering and generate a sharp contrast, while a particle size several times larger than the wavelength would absorb or obstruct the light path. The naturally occurring contrast agent could provide a diagnostic biomarker of lung tissue in smokers. Furthermore, carbon under such circumstances, can be used as an effective exogenous contrast agent, with which specific components or tissues exhibiting early tumour formation can be optically labelled to delineate the location and boundary, providing potential for early cancer detection and its treatment

  10. Colloidal dispersions of maghemite nanoparticles produced by laser pyrolysis with application as NMR contrast agents

    Energy Technology Data Exchange (ETDEWEB)

    Veintemillas-Verdaguer, Sabino [Instituto de Ciencia de Materiales de Madrid, CSIC, Cantoblanco, 28049 Madrid (Spain); Morales, Maria del Puerto [Instituto de Ciencia de Materiales de Madrid, CSIC, Cantoblanco, 28049 Madrid (Spain); Bomati-Miguel, Oscar [Instituto de Ciencia de Materiales de Madrid, CSIC, Cantoblanco, 28049 Madrid (Spain); Bautista, Carmen [Instituto de Ciencia de Materiales de Madrid, CSIC, Cantoblanco, 28049 Madrid (Spain); Zhao, Xinqing [Instituto de Ciencia de Materiales de Madrid, CSIC, Cantoblanco, 28049 Madrid (Spain); Bonville, Pierre [CEA, CE Saclay, DSM/DRECAM/SPEC, 91191 Gif-Sur-Yvette (France); Alejo, Rigoberto Perez de [Universidad Complutense de Madrid, Unidad de RMN, Paseo Juan XXIII, 1, 28040 Madrid (Spain); Ruiz-Cabello, Jesus [Universidad Complutense de Madrid, Unidad de RMN, Paseo Juan XXIII, 1, 28040 Madrid (Spain); Santos, Martin [Hospital Universitario Puerta de Hierro, Servicio de Cirugia Experimental. C/San Martin de Porres 4, 28035 Madrid (Spain); Tendillo-Cortijo, Francisco J [Hospital Universitario Puerta de Hierro, Servicio de Cirugia Experimental. C/San Martin de Porres 4, 28035 Madrid (Spain); Ferreiros, Joaquin [Hospital Clinico de Madrid ' San Carlos' , Ciudad Universitaria, 28040 Madrid (Spain)

    2004-08-07

    Biocompatible magnetic dispersions have been prepared from {gamma}-Fe{sub 2}O{sub 3} nanoparticles (5 nm) synthesized by continuous laser pyrolysis of Fe(CO){sub 5} vapours. The feasibility of using these dispersions as magnetic resonance imaging (MRI) contrast agents has been analysed in terms of chemical structure, magnetic properties, {sup 1}H NMR relaxation times and biokinetics. The magnetic nanoparticles were dispersed in a strong alkaline solution in the presence of dextran, yielding stable colloids in a single step. The dispersions consist of particle-aggregates 25 nm in diameter measured using transmission electron microscope and a hydrodynamic diameter of 42 nm measured using photon correlation spectroscopy. The magnetic and relaxometric properties of the dispersions were of the same order of magnitude as those of commercial contrast agents produced using coprecipitation. However, these dispersions, when injected intravenously in rats at standard doses showed a mono-exponential blood clearance instead of a biexponential one, with a blood half-life of 7 {+-} 1 min. Furthermore, an important enhancement of the image contrast was observed after the injection, mainly located at the liver and the spleen of the rat. In conclusion, the laser pyrolysis technique seems to be a good alternative to the coprecipitation method for producing MRI contrast agents, with the advantage of being a continuous synthesis method that leads to very uniform particles capable of being dispersed and therefore transformed in a biocompatible magnetic liquid.

  11. Biocompatible KMnF3 nanoparticular contrast agent with proper plasma retention time for in vivo magnetic resonance imaging.

    Science.gov (United States)

    Liu, Zhi-jun; Song, Xiao-xia; Xu, Xian-zhu; Tang, Qun

    2014-04-18

    Nanoparticular MRI contrast agents are rapidly becoming suitable for use in clinical diagnosis. An ideal nanoparticular contrast agent should be endowed with high relaxivity, biocompatibility, proper plasma retention time, and tissue-specific or tumor-targeting imaging. Herein we introduce PEGylated KMnF3 nanoparticles as a new type of T1 contrast agent. Studies showed that the nanoparticular contrast agent revealed high bio-stability with bovine serum albumin in PBS buffer solution, and presented excellent biocompatibility (low cytotoxicity, undetectable hemolysis and hemagglutination). Meanwhile the new contrast agent possessed proper plasma retention time (circulation half-life t1/2 is approximately 2 h) in the body of the administrated mice. It can be delivered into brain vessels and maintained there for hours, and is mostly cleared from the body within 48 h, as demonstrated by time-resolved MRI and Mn-biodistribution analysis. Those distinguishing features make it suitable to obtain contrast-enhanced brain magnetic resonance angiography. Moreover, through the process of passive targeting delivery, the T1 contrast agent clearly illuminates a brain tumor (glioma) with high contrast image and defined shape. This study demonstrates that PEGylated KMnF3 nanoparticles represent a promising biocompatible vascular contrast agent for magnetic resonance angiography and can potentially be further developed into an active targeted tumor MRI contrast agent.

  12. Magnetic resonance angiography with blood-pool contrast agents: future applications

    Energy Technology Data Exchange (ETDEWEB)

    Fink, C. [Univ. Hospitals, Grosshadern, Munich (Germany); Goyen, M. [Univ. Medical Center, Hamburg-Eppendorf, Hamburg (Germany); Lotz, J. [Hannover Medical School, Hannover (Germany)

    2007-03-15

    Blood pool agents remain in the intravascular space for a longer time period. Therefore the optimal imaging window for vascular structures is widened to about 30 minutes. Gadofosveset trisodium (Vasovist, Bayer Schering Pharma AG, Berlin, Germany) is the first blood-pool contrast agent approved in Europe for contrast-enhanced magnetic resonance angiography (MRA) of vessels in the abdomen, pelvis and lower extremity in adults. Other possible applications of blood-pool agents are now being considered, such as assessment of venous thromboembolism, coronary artery disease or sinus venous thrombosis. Perfusion MR imaging holds promise for detecting lung perfusion defects with higher spatial resolution and reduced scan time compared with radionuclide scintigraphy. In coronary artery disease, blood-pool agents enable a substantial increase in the quality of coronary artery imaging. Quantitative myocardial perfusion and myocardial viability seem to be possible, although modifications in protocols and sequence design are necessary for optimal results. Other novel applications of blood-pool agents include monitoring of inflammatory changes in systemic lupus erythematosus and evaluation of tumour invasion into lymph nodes and more reliable assessment of cerebral venous and sinus thrombosis. (orig.)

  13. Magnetic resonance angiography with blood-pool contrast agents: future applications

    International Nuclear Information System (INIS)

    Fink, C.; Goyen, M.; Lotz, J.

    2007-01-01

    Blood pool agents remain in the intravascular space for a longer time period. Therefore the optimal imaging window for vascular structures is widened to about 30 minutes. Gadofosveset trisodium (Vasovist, Bayer Schering Pharma AG, Berlin, Germany) is the first blood-pool contrast agent approved in Europe for contrast-enhanced magnetic resonance angiography (MRA) of vessels in the abdomen, pelvis and lower extremity in adults. Other possible applications of blood-pool agents are now being considered, such as assessment of venous thromboembolism, coronary artery disease or sinus venous thrombosis. Perfusion MR imaging holds promise for detecting lung perfusion defects with higher spatial resolution and reduced scan time compared with radionuclide scintigraphy. In coronary artery disease, blood-pool agents enable a substantial increase in the quality of coronary artery imaging. Quantitative myocardial perfusion and myocardial viability seem to be possible, although modifications in protocols and sequence design are necessary for optimal results. Other novel applications of blood-pool agents include monitoring of inflammatory changes in systemic lupus erythematosus and evaluation of tumour invasion into lymph nodes and more reliable assessment of cerebral venous and sinus thrombosis. (orig.)

  14. Contrast media and glomerular filtration: dose dependence of clearance for three agents

    International Nuclear Information System (INIS)

    Baeck, S.E.K.; Krutzen, E.; Nilsson-Ehle, P.

    1988-01-01

    Determination of plasma clearance of contrast agents has been advocated as a means to assess glomerular filtration rate. To evaluate the feasibility of different agents for this purpose, we have compared, in healthy volunteers, the dose dependence of plasma clearance for three contrast media (iohexol, a nonionic agent, and iothalamate and metrizoate, which are ionic substances), with special emphasis on the lower dose range (2-20 mL corresponding to 0.9-12.9 g, depending on dose and agent). Iohexol and iothalamate were cleared at constant rates, irrespective of given dose, whereas metrizoate clearance increased significantly at lower doses. In general, the clearances or iothalamate and metrizoate were, respectively, moderately and markedly higher than that of iohexol. The clearance of different doses of metrizoate (2 mL versus a radiographic dose of 40 mL or more) was also compared with the clearance of [ 51 Cr]EDTA in two groups of patients with reduced renal function. When compared with [ 51 Cr]EDTA in patients with renal dysfunction, metrizoate was cleared significantly faster after a 2-mL dose, whereas clearances were identical when the metrizoate dose was 40 mL or more. These findings indicate that tubular secretion plays an active role in the elimination of metrizoate. The pharmacokinetic properties of iohexol, in combination with its low toxicity, make it a suitable agent for determination of glomerular filtration rate in clinical practice

  15. The impact of injector-based contrast agent administration in time-resolved MRA.

    Science.gov (United States)

    Budjan, Johannes; Attenberger, Ulrike I; Schoenberg, Stefan O; Pietsch, Hubertus; Jost, Gregor

    2018-05-01

    Time-resolved contrast-enhanced MR angiography (4D-MRA), which allows the simultaneous visualization of the vasculature and blood-flow dynamics, is widely used in clinical routine. In this study, the impact of two different contrast agent injection methods on 4D-MRA was examined in a controlled, standardized setting in an animal model. Six anesthetized Goettingen minipigs underwent two identical 4D-MRA examinations at 1.5 T in a single session. The contrast agent (0.1 mmol/kg body weight gadobutrol, followed by 20 ml saline) was injected using either manual injection or an automated injection system. A quantitative comparison of vascular signal enhancement and quantitative renal perfusion analyses were performed. Analysis of signal enhancement revealed higher peak enhancements and shorter time to peak intervals for the automated injection. Significantly different bolus shapes were found: automated injection resulted in a compact first-pass bolus shape clearly separated from the recirculation while manual injection resulted in a disrupted first-pass bolus with two peaks. In the quantitative perfusion analyses, statistically significant differences in plasma flow values were found between the injection methods. The results of both qualitative and quantitative 4D-MRA depend on the contrast agent injection method, with automated injection providing more defined bolus shapes and more standardized examination protocols. • Automated and manual contrast agent injection result in different bolus shapes in 4D-MRA. • Manual injection results in an undefined and interrupted bolus with two peaks. • Automated injection provides more defined bolus shapes. • Automated injection can lead to more standardized examination protocols.

  16. Iron-EHPG as an hepatobiliary MR contrast agent: initial imaging and biodistribution studies

    International Nuclear Information System (INIS)

    Lauffer, R.B.; Greif, W.L.; Stark, D.D.; Vincent, A.C.; Saini, S.; Wedeen, V.J.; Brady, T.J.

    1988-01-01

    A paramagnetic relaxation agent targeted to functioning hepatocytes of the liver and excreted into the bile would be useful in the enhancement of normal liver and biliary anatomy in MR imaging. We sought to demonstrate the feasibility of this approach using the prototype hepatobiliary MR contrast agent, iron(III) ethylenebis-(2-hydroxyphenylglycine) (Fe(EHPG) - ). The biodistribution, relaxation enhancement, and imaging characteristics of Fe(EHPG) - were compared to those of the non-specific iron chelate iron(III) diethylenetriaminepentaacetic acid (Fe(DTPA) 2- ), which has a comparable effect on water proton relaxation times. (author)

  17. Synthesis and evaluation of nanoglobule-cystamine-(Gd-DO3A, a biodegradable nanosized magnetic resonance contrast agent for dynamic contrast-enhanced magnetic resonance urography

    Directory of Open Access Journals (Sweden)

    Rongzuo Xu

    2010-09-01

    Full Text Available Rongzuo Xu1, Todd Lyle Kaneshiro1, Eun-Kee Jeong2, Dennis L Parker2, Zheng-Rong Lu31Department of Pharmaceutics and Pharmaceutical Chemistry, University of Utah, Salt Lake City, UT, USA; 2Department of Radiology, University of Utah, Salt Lake City, UT, USA; 3Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, USAAbstract: Dynamic contrast-enhanced magnetic resonance imaging has been recently shown to be effective for diagnostic urography. High-resolution urographic images can be acquired with T1 contrast agents for the kidney and urinary tract with minimal noise in the abdomen. Currently, clinical contrast agents are low molecular weight agents and can rapidly extravasate from blood circulation, leading to slow contrast agent elimination through kidney and consequently providing limited contrast enhancement in urinary tract. In this study, a new biodegradable macromolecular contrast agent, nanoglobule-G4-cystamine-(Gd-DO3A, was prepared by conjugating Gd-DO3A chelates on the surface of a generation 4 nanoglobule, poly-l-lysine octa(3-aminopropylsilsesquioxane dendrimer, via a disulfide spacer, where the carrier had a precisely defined nanosize that is far smaller than the renal filtration threshold. The in vivo contrast enhancement and dynamic imaging of the urinary tract of the agent was evaluated in nude mice using a low molecular weight agent Gd(DTPA-BMA as a control. The agent eliminated rapidly from blood circulation and accumulated more abundantly in urinary tract than Gd(DTPA-BMA. The fast elimination kinetics is ideal for functional evaluation of the kidneys. The morphology of the kidneys and urinary tract was better visualized by the biodegradable nanoglobular contrast agent than Gd(DTPA-BMA. The agent also resulted in low liver contrast enhancement, indicating low nonspecific tissue deposition. These features render the G4 nanoglobule-cystamine-(Gd-DO3A conjugate a promising contrast agent for magnetic

  18. Magnetic resonance imaging with liver-specific contrast agent in primary amyloidosis and intrahepatic cholestasis

    Energy Technology Data Exchange (ETDEWEB)

    Moeller, J.M.; Santoni-Rugiu, E.; Chabanova, E.; Logager, V.; Hansen, A.B.; Thomsen, H.S. [Depts. of Radiology and Pathology, Copenhagen Univ. Hospital, Herlev (Denmark)

    2007-02-15

    Magnetic resonance imaging (MRI) findings in hepatic amyloidosis are not well defined. Here, we report on a patient with renal failure caused by primary amyloidosis (AL type) who developed jaundice. Ultrasound and computed tomography were normal except for some ascites. MRI with oral manganese-containing contrast agent revealed several focal areas without contrast uptake in the hepatocytes and no bile secretion after 8 hours. No extrahepatic bile obstructions were found. Liver biopsy showed severe intraportal, vascular, and parenchymal amyloidosis causing severe cholestasis and atrophy of hepatocytes.

  19. Hafnium-Based Contrast Agents for X-ray Computed Tomography.

    Science.gov (United States)

    Berger, Markus; Bauser, Marcus; Frenzel, Thomas; Hilger, Christoph Stephan; Jost, Gregor; Lauria, Silvia; Morgenstern, Bernd; Neis, Christian; Pietsch, Hubertus; Sülzle, Detlev; Hegetschweiler, Kaspar

    2017-05-15

    Heavy-metal-based contrast agents (CAs) offer enhanced X-ray absorption for X-ray computed tomography (CT) compared to the currently used iodinated CAs. We report the discovery of new lanthanide and hafnium azainositol complexes and their optimization with respect to high water solubility and stability. Our efforts culminated in the synthesis of BAY-576, an uncharged hafnium complex with 3:2 stoichiometry and broken complex symmetry. The superior properties of this asymmetrically substituted hafnium CA were demonstrated by a CT angiography study in rabbits that revealed excellent signal contrast enhancement.

  20. Relaxivity of blood pool contrast agent depends on the host tissue as suggested by semianalytical simulations

    DEFF Research Database (Denmark)

    Kjølby, Birgitte Fuglsang; Østergaard, Leif; Kiselev, Valerij

    Concentration of magnetic resonance imaging (MRI) contrast agents (CA) cannot be measured directly and is commonly determined indirectly using their relaxation effect. This requires knowledge of the relaxivity of the used CA. Quantitative perfusion studies involve measurement of CA concentration...... studies (3,4) as demonstrated in (5). It was previously found (6) that the perfusion measurements using dynamic susceptibility contrast inherently overestimate cerebral blood flow and volume. In view of the present result, this is attributed to the significant difference in the relaxivity of the CA...

  1. Ultrasound-mediated vascular gene transfection by cavitation of endothelial-targeted cationic microbubbles.

    Science.gov (United States)

    Xie, Aris; Belcik, Todd; Qi, Yue; Morgan, Terry K; Champaneri, Shivam A; Taylor, Sarah; Davidson, Brian P; Zhao, Yan; Klibanov, Alexander L; Kuliszewski, Michael A; Leong-Poi, Howard; Ammi, Azzdine; Lindner, Jonathan R

    2012-12-01

    Ultrasound-mediated gene delivery can be amplified by acoustic disruption of microbubble carriers that undergo cavitation. We hypothesized that endothelial targeting of microbubbles bearing cDNA is feasible and, through optimizing proximity to the vessel wall, increases the efficacy of gene transfection. Contrast ultrasound-mediated gene delivery is a promising approach for site-specific gene therapy, although there are concerns with the reproducibility of this technique and the safety when using high-power ultrasound. Cationic lipid-shelled decafluorobutane microbubbles bearing a targeting moiety were prepared and compared with nontargeted microbubbles. Microbubble targeting efficiency to endothelial adhesion molecules (P-selectin or intercellular adhesion molecule [ICAM]-1) was tested using in vitro flow chamber studies, intravital microscopy of tumor necrosis factor-alpha (TNF-α)-stimulated murine cremaster muscle, and targeted contrast ultrasound imaging of P-selectin in a model of murine limb ischemia. Ultrasound-mediated transfection of luciferase reporter plasmid charge coupled to microbubbles in the post-ischemic hindlimb muscle was assessed by in vivo optical imaging. Charge coupling of cDNA to the microbubble surface was not influenced by the presence of targeting ligand, and did not alter the cavitation properties of cationic microbubbles. In flow chamber studies, surface conjugation of cDNA did not affect attachment of targeted microbubbles at microvascular shear stresses (0.6 and 1.5 dyne/cm(2)). Attachment in vivo was also not affected by cDNA according to intravital microscopy observations of venular adhesion of ICAM-1-targeted microbubbles and by ultrasound molecular imaging of P-selectin-targeted microbubbles in the post-ischemic hindlimb in mice. Transfection at the site of high acoustic pressures (1.0 and 1.8 MPa) was similar for control and P-selectin-targeted microbubbles but was associated with vascular rupture and hemorrhage. At 0.6 MPa

  2. Imaging efficiency of an X-ray contrast agent-incorporated polymeric microparticle.

    Science.gov (United States)

    Ahn, Sungsook; Jung, Sung Yong; Lee, Jin Pyung; Lee, Sang Joon

    2011-01-01

    Biocompatible polymeric encapsulants have been widely used as a delivery vehicle for a variety of drugs and imaging agents. In this study, X-ray contrast agent (iopamidol) is encapsulated into a polymeric microparticle (polyvinyl alcohol) as a particulate flow tracer in synchrotron X-ray imaging system. The physical properties of the designed microparticles are investigated and correlated with enhancement in the imaging efficiency by experimental observation and theoretical interpretation. The X-ray absorption ability of the designed microparticle is assessed by Beer-Lambert-Bouguer law. Particle size, either in dried state or in solvent, primarily dominates the X-ray absorption ability under the given condition, thus affecting imaging efficiency of the designed X-ray contrast flow tracers. Copyright © 2011 John Wiley & Sons, Ltd.

  3. An analytical study of photoacoustic and thermoacoustic generation efficiency towards contrast agent and film design optimization

    Directory of Open Access Journals (Sweden)

    Fei Gao

    2017-09-01

    Full Text Available Photoacoustic (PA and thermoacoustic (TA effects have been explored in many applications, such as bio-imaging, laser-induced ultrasound generator, and sensitive electromagnetic (EM wave film sensor. In this paper, we propose a compact analytical PA/TA generation model to incorporate EM, thermal and mechanical parameters, etc. From the derived analytical model, both intuitive predictions and quantitative simulations are performed. It shows that beyond the EM absorption improvement, there are many other physical parameters that deserve careful consideration when designing contrast agents or film composites, followed by simulation study. Lastly, several sets of experimental results are presented to prove the feasibility of the proposed analytical model. Overall, the proposed compact model could work as a clear guidance and predication for improved PA/TA contrast agents and film generator/sensor designs in the domain area.

  4. Myocardial Contrast Agents – Safety Considerations and Clinical Efficacy in Stress Echocardiography

    Directory of Open Access Journals (Sweden)

    Maier Anca

    2016-11-01

    Full Text Available Transthoracic echocardiographic examination is known to be a safe, non-invasive and reproducible method, used in every day clinical practice to obtain important information about cardiac structure and function. Unfortunately, a significant proportion of studies have highlighted the considerable technically difficultly in producing diagnostic images due to a poor acoustic window and more than 33% of patients undergoing stress echocardiography have suboptimal echocardiographic images. All these limitations have led to the use of contrast agents to improve the quality of standard ultrasound examination to provide a better delineation of left ventricle endocardial borders or to obtain information that cannot be achieved by using standard echocardiography, such as assessing myocardial microcirculation and therefore perfusion. This paper sought to review the clinical efficacy and safety of ultrasound contrast agents focusing on stress echocardiography.

  5. Semiconducting polymer dot as a highly effective contrast agent for photoacoustic imaging

    Science.gov (United States)

    Yuan, Zhen; Zhang, Jian

    2018-02-01

    In this study, we developed a novel PIID-DTBT based semiconducting polymer dots (Pdots) that have broad and strong optical absorption in the visible-light region (500 nm - 700 nm). Gold nanoparticles (GNPs) and gold nanorods (GNRs) that have been verified as an excellent photoacoustic contrast agent were compared with Pdots based on photoacoustic imaging method. Both ex vivo and in vivo experiment demonstrated Pdots have a better photoacoustic conversion efficiency at 532 nm than GNPs and similar photoacoustic performance with GNRs at 700 nm at the same mass concentration. Our work demonstrates the great potential of Pdots as a highly effective contrast agent for precise localization of lesions relative to the blood vessels based on photoacoustic tomography imaging.

  6. Targeted nanodiamonds as phenotype-specific photoacoustic contrast agents for breast cancer.

    Science.gov (United States)

    Zhang, Ti; Cui, Huizhong; Fang, Chia-Yi; Cheng, Kun; Yang, Xinmai; Chang, Huan-Cheng; Forrest, M Laird

    2015-03-01

    The aim is to develop irradiated nanodiamonds (INDs) as a molecularly targeted contrast agent for high-resolution and phenotype-specific detection of breast cancer with photoacoustic (PA) imaging. The surface of acid treated radiation-damaged nanodiamonds was grafted with PEG to improve its stability and circulation time in blood, followed by conjugation to an anti-HER2 peptide with a final nanoparticle size of approximately 92 nm. Immunocompetent mice bearing orthotopic HER2-positive or negative tumors were administered INDs and PA imaged using an 820-nm near-infrared laser. PA images demonstrated that INDs accumulate in tumors and completely delineated the entire tumor within 10 h. HER2 targeting significantly enhanced imaging of HER2-positive tumors. Pathological examination demonstrated INDs are nontoxic. PA technology is adaptable to low-cost bedside medicine, and with new contrast agents described herein, PA can achieve high-resolution (sub-mm) and phenotype-specific monitoring of cancer growth.

  7. Biocompatible Polyhydroxyethylaspartamide-based Micelles with Gadolinium for MRI Contrast Agents

    Directory of Open Access Journals (Sweden)

    Kim Hyo Jeong

    2010-01-01

    Full Text Available Abstract Biocompatible poly-[N-(2-hydroxyethyl-d,l-aspartamide]-methoxypoly(ethyleneglycol-hexadecylamine (PHEA-mPEG-C16 conjugated with 1,4,7,10-tetraazacyclododecan-1,4,7,10-tetraacetic acid-gadolinium (DOTA-Gd via ethylenediamine (ED was synthesized as a magnetic resonance imaging (MRI contrast agent. Amphiphilic PHEA-mPEG-C16-ED-DOTA-Gd forms micelle in aqueous solution. All the synthesized materials were characterized by proton nuclear magnetic resonance (1H NMR. Micelle size and shape were examined by dynamic light scattering (DLS and atomic force microscopy (AFM. Micelles with PHEA-mPEG-C16-ED-DOTA-Gd showed higher relaxivities than the commercially available gadolinium contrast agent. Moreover, the signal intensity of a rabbit liver was effectively increased after intravenous injection of PHEA-mPEG-C16-ED-DOTA-Gd.

  8. Preclinical animal acute toxicity studies of new developed MRI contrast agent based on gadolinium

    Science.gov (United States)

    Nam, I. F.; Zhuk, V. V.

    2015-04-01

    Acute toxicity test of new developed MRI contrast agent based on disodium salt of gadopentetic acid complex were carried out on Mus musculus and Sprague Dawley rats according to guidelines of preclinical studies [1]. Groups of six animals each were selected for experiment. Death and clinical symptoms of animals were recorded during 14 days. As a result the maximum tolerated dose (MTD) for female mice is 2.8 mM/kg of body weight, male mice - 1.4 mM/kg, female rats - 2.8 mM/kg, male rats - 5.6 mM/kg of body weight. No Observed Adverse Effect Dose (NOAEL) for female mice is 1.4 mM/kg, male mice - 0.7 mM/kg, male and female rats - 0.7 mM/kg. According to experimental data new developed MRI contrast agent based on Gd-DTPA complex is low-toxic.

  9. Spark channel propagation in a microbubble liquid

    Energy Technology Data Exchange (ETDEWEB)

    Panov, V. A.; Vasilyak, L. M., E-mail: vasilyak@ihed.ras.ru; Vetchinin, S. P.; Pecherkin, V. Ya.; Son, E. E. [Russian Academy of Sciences, Joint Institute for High Temperatures (Russian Federation)

    2016-11-15

    Experimental study on the development of the spark channel from the anode needle under pulsed electrical breakdown of isopropyl alcohol solution in water with air microbubbles has been performed. The presence of the microbubbles increases the velocity of the spark channel propagation and increases the current in the discharge gap circuit. The observed rate of spark channel propagation in microbubble liquid ranges from 4 to 12 m/s, indicating the thermal mechanism of the spark channel development in a microbubble liquid.

  10. Performance characteristics of magnetic resonance imaging without contrast agents or sedation in pediatric appendicitis

    Energy Technology Data Exchange (ETDEWEB)

    Didier, Ryne A.; Hopkins, Katharine L.; Coakley, Fergus V.; Foster, Bryan R. [Oregon Health and Science University, Department of Diagnostic Radiology, Portland, OR (United States); Krishnaswami, Sanjay [Oregon Health and Science University, Department of Surgery, Portland, OR (United States); Oregon Health and Science University, Department of Pediatrics, Portland, OR (United States); Spiro, David M. [Oregon Health and Science University, Department of Pediatrics, Portland, OR (United States)

    2017-09-15

    Magnetic resonance imaging (MRI) has emerged as a promising modality for evaluating pediatric appendicitis. However optimal imaging protocols, including roles of contrast agents and sedation, have not been established and diagnostic criteria have not been fully evaluated. To investigate performance characteristics of rapid MRI without contrast agents or sedation in the diagnosis of pediatric appendicitis. We included patients ages 4-18 years with suspicion of appendicitis who underwent rapid MRI between October 2013 and March 2015 without contrast agent or sedation. After two-radiologist review, we determined performance characteristics of individual diagnostic criteria and aggregate diagnostic criteria by comparing MRI results to clinical outcomes. We used receiver operating characteristic (ROC) curves to determine cut-points for appendiceal diameter and wall thickness for optimization of predictive power, and we calculated area under the curve (AUC) as a measure of test accuracy. Ninety-eight MRI examinations were performed in 97 subjects. Overall, MRI had a 94% sensitivity, 95% specificity, 91% positive predictive value and 97% negative predictive value. Optimal cut-points for appendiceal diameter and wall thickness were ≥7 mm and ≥2 mm, respectively. Independently, those cut-points produced sensitivities of 91% and 84% and specificities of 84% and 43%. Presence of intraluminal fluid (30/33) or localized periappendiceal fluid (32/33) showed a significant association with acute appendicitis (P<0.01), with sensitivities of 91% and 97% and specificities of 60% and 50%. For examinations in which the appendix was not identified by one or both reviewers (23/98), the clinical outcome was negative. Rapid MRI without contrast agents or sedation is accurate for diagnosis of pediatric appendicitis when multiple diagnostic criteria are considered in aggregate. Individual diagnostic criteria including optimized cut-points of ≥7 mm for diameter and ≥2 mm for wall

  11. Screening and Monitoring Response to Treatment Using Subsecond Molecular Imaging and Hyperpolarized Contrast Agents

    Science.gov (United States)

    2013-05-01

    DCE-MRI analysis typically involves the application of various pharmacokinetic equations to model the movement of contrast agent molecules between...position over a short time interval due to random, thermally-induced motion (ie, Brownian motion). DW-MRI exploits applied gradients of the main...intracel- lular organelles tend to restrict or hinder the free movement of water.47,48 Moreover, cancerous tissues often show sig- nificantly reduced ADC

  12. Performance characteristics of magnetic resonance imaging without contrast agents or sedation in pediatric appendicitis

    International Nuclear Information System (INIS)

    Didier, Ryne A.; Hopkins, Katharine L.; Coakley, Fergus V.; Foster, Bryan R.; Krishnaswami, Sanjay; Spiro, David M.

    2017-01-01

    Magnetic resonance imaging (MRI) has emerged as a promising modality for evaluating pediatric appendicitis. However optimal imaging protocols, including roles of contrast agents and sedation, have not been established and diagnostic criteria have not been fully evaluated. To investigate performance characteristics of rapid MRI without contrast agents or sedation in the diagnosis of pediatric appendicitis. We included patients ages 4-18 years with suspicion of appendicitis who underwent rapid MRI between October 2013 and March 2015 without contrast agent or sedation. After two-radiologist review, we determined performance characteristics of individual diagnostic criteria and aggregate diagnostic criteria by comparing MRI results to clinical outcomes. We used receiver operating characteristic (ROC) curves to determine cut-points for appendiceal diameter and wall thickness for optimization of predictive power, and we calculated area under the curve (AUC) as a measure of test accuracy. Ninety-eight MRI examinations were performed in 97 subjects. Overall, MRI had a 94% sensitivity, 95% specificity, 91% positive predictive value and 97% negative predictive value. Optimal cut-points for appendiceal diameter and wall thickness were ≥7 mm and ≥2 mm, respectively. Independently, those cut-points produced sensitivities of 91% and 84% and specificities of 84% and 43%. Presence of intraluminal fluid (30/33) or localized periappendiceal fluid (32/33) showed a significant association with acute appendicitis (P<0.01), with sensitivities of 91% and 97% and specificities of 60% and 50%. For examinations in which the appendix was not identified by one or both reviewers (23/98), the clinical outcome was negative. Rapid MRI without contrast agents or sedation is accurate for diagnosis of pediatric appendicitis when multiple diagnostic criteria are considered in aggregate. Individual diagnostic criteria including optimized cut-points of ≥7 mm for diameter and ≥2 mm for wall

  13. Early Detection of Prostate Cancer with New Nanoparticle Based UltrasoundContrast Agents Targeted to PSMA

    Science.gov (United States)

    2017-08-01

    in learning and careers in science, technology, and the humanities. What do you plan to do during the next reporting period to accomplish...Report.” Describe how results from the project made an impact, or are likely to make an impact, beyond the bounds of science, engineering , and the...Lipid Acyl Chain Length Improves Stability of Nano-sized Ultrasound Contrast Agents In Vitro. Biomedical Engineering Society 2017 meeting. Under review

  14. Assessment of myocardial infarction by magnetic resonance imaging with the aid of contrast agents

    International Nuclear Information System (INIS)

    Roos, A. de; Doornbos, J.

    1991-01-01

    The potential of MR imaging in myocardial ischemia with low-temporal-resolution spin-echo techniques both with and without MR contrast agents has been explored. There are indications that early MR imaging after administration of Gd-DTPA is capable to differentiate reperfused from non-reperfused infarcts. Furthermore, MR infarct sizing using Gd-DTPA is feasible to demonstrate infarct size reduction in patients with successful reperfusion. (H.W.). 50 refs.; 9 figs

  15. Chitosan-coated nickel-ferrite nanoparticles as contrast agents in magnetic resonance imaging

    International Nuclear Information System (INIS)

    Ahmad, Tanveer; Bae, Hongsub; Iqbal, Yousaf; Rhee, Ilsu; Hong, Sungwook; Chang, Yongmin; Lee, Jaejun; Sohn, Derac

    2015-01-01

    We report evidence for the possible application of chitosan-coated nickel-ferrite (NiFe 2 O 4 ) nanoparticles as both T 1 and T 2 contrast agents in magnetic resonance imaging (MRI). The coating of nickel-ferrite nanoparticles with chitosan was performed simultaneously with the synthesis of the nickel-ferrite nanoparticles by a chemical co-precipitation method. The coated nanoparticles were cylindrical in shape with an average length of 17 nm and an average width of 4.4 nm. The bonding of chitosan onto the ferrite nanoparticles was confirmed by Fourier transform infrared spectroscopy. The T 1 and T 2 relaxivities were 0.858±0.04 and 1.71±0.03 mM −1 s −1 , respectively. In animal experimentation, both a 25% signal enhancement in the T 1 -weighted mage and a 71% signal loss in the T 2 -weighted image were observed. This demonstrated that chitosan-coated nickel-ferrite nanoparticles are suitable as both T 1 and T 2 contrast agents in MRI. We note that the applicability of our nanoparticles as both T 1 and T 2 contrast agents is due to their cylindrical shape, which gives rise to both inner and outer sphere processes of nanoparticles. - Highlights: • Chitosan-coated nickel-ferrite (Ni-Fe 2 O 4 ) nanoparticles were synthesized in an aqueous system by chemical co-precipitation. • The characterization of bare and chitosan-coated nanoparticles were performed using various analytical tools, such as TEM, FTIR, XRD, and VMS. • We evaluated the coated particles as potential T 1 and T 2 contrast agents for MRI by measuring T 1 and T 2 relaxation times as a function of iron concentration. • Both T 1 and T 2 effects were also observed in animal experimentation

  16. Relationship between cavitation and loss of echogenicity from ultrasound contrast agents

    OpenAIRE

    Radhakrishnan, Kirthi; Bader, Kenneth B; Haworth, Kevin J; Kopechek, Jonathan A; Raymond, Jason L; Huang, Shao-Ling; McPherson, David D; Holland, Christy K

    2013-01-01

    Ultrasound contrast agents (UCAs) have the potential to nucleate cavitation and promote both beneficial and deleterious bioeffects in vivo. Previous studies have elucidated the pulse-duration dependent pressure amplitude threshold for rapid loss of echogenicity due to UCA fragmentation. Previous studies have demonstrated that UCA fragmentation was concomitant with inertial cavitation. The purpose of this study was to evaluate the relationship between stable and inertial cavitation thresholds ...

  17. A novel nitroreductase-enhanced MRI contrast agent and its potential application in bacterial imaging

    Directory of Open Access Journals (Sweden)

    Yun Liu

    2018-05-01

    Full Text Available Nitroreductases (NTRs are known to be able to metabolize nitro-substituted compounds in the presence of reduced nicotinamide adenine dinucleotide (NADH as an electron donor. NTRs are present in a wide range of bacterial genera and, to a lesser extent, in eukaryotes hypoxic tumour cells and tumorous tissues, which makes it an appropriate biomarker for an imaging target to detect the hypoxic status of cancer cells and potential bacterial infections. To evaluate the specific activation level of NTR, great efforts have been devoted to the development of fluorescent probes to detect NTR activities using fluorogenic methods to probe its behaviour in a cellular context; however, NTR-responsive MRI contrast agents are still by far underexplored. In this study, para-nitrobenzyl substituted T1-weighted magnetic resonance imaging (MRI contrast agent Gd-DOTA-PNB (probe 1 has been designed and explored for the possible detection of NTR. Our experimental results show that probe 1 could serve as an MRI-enhanced contrast agent for monitoring NTR activity. The in vitro response and mechanism of the NTR catalysed reduction of probe 1 have been investigated through LC–MS and MRI. Para-nitrobenzyl substituted probe 1 was catalytically reduced by NTR to the intermediate para-aminobenzyl substituted probe which then underwent a rearrangement elimination reaction to Gd-DOTA, generating the enhanced T1-weighted MR imaging. Further, LC–MS and MRI studies of living Escherichia coli have confirmed the NTR activity detection ability of probe 1 at a cellular level. This method may potentially be used for the diagnosis of bacterial infections. KEY WORDS: Nitroreductase, MRI contrast agent, Smart imaging probes, Bacterial imaging, Bacterial infection

  18. Metal-oxo containing polymer nanobeads as potential contrast agents for magnetic resonance imaging

    Science.gov (United States)

    Pablico, Michele Huelar

    Magnetic resonance imaging (MRI) has greatly revolutionized the way diseases are detected and treated, as it is a non-invasive imaging modality solely based on the interaction of radiowaves and hydrogen nuclei in the presence of an external magnetic field. It is widely used today for the diagnosis of diseases as it offers an efficient method of mapping structure and function of soft tissues in the body. Most MRI examinations utilize paramagnetic materials known as contrast agents, which enhance the MR signal by decreasing the longitudinal (T1) and transverse (T2) relaxation times of the surrounding water protons in biological systems. This results into increased signal intensity differences thereby allowing better interpretation and analysis of pathological tissues. Contrast agents function by lowering the T1 or lowering the T2, resulting into bright and dark contrasts, respectively. The most common MRI contrast agents that are in clinical use today are gadolinium chelates and superparamagnetic iron oxide nanoparticles, both of which have their own advantages in terms of contrast enhancement properties. In the past few years, however, there has been interest in utilizing metal-containing clusters for MRI contrast enhancement as these materials bridge the gap between the constrained structure and magnetic properties of the gadolinium chelates with the superparamagnetic behavior of the iron oxide nanoparticles. Recently, metallic clusters containing Mn and Fe metal centers have received increased attention mainly because of their potential for high spin states and benign nature. In the quest to further develop novel imaging agents, this research has focused on investigating the use of metal-oxo clusters as potential contrast agents for MRI. The primary goal of this project is to identify clusters that meet the following criteria: high paramagnetic susceptibility, water-soluble, stable, cheap, contain environmentally benign metals, and easily derivatized. This work is

  19. Evaluation of potential practical oral contrast agents for pediatric magnetic resonance imaging

    International Nuclear Information System (INIS)

    Bisset, G.S. III; Cincinnati Univ., OH; Children's Hospital Medical Center, Cincinnati, OH

    1989-01-01

    Development of a practical oral contrast agent for magnetic resonance imaging is necessary to improve differentiation of bowel from adjacent structures. In order to find a readily available, inexpensive, non-toxic, palatable solution for use in the pediatric population, several formulas, milk products and a common oral sedative were evaluated in vitro. T1, T2 and signal intensity measurements were performed on a 1.5 T system. Similac with standard iron proved to be a useful high signal intensity agent on multiple pulse sequences. Early in vivo experience in four normal volunteers indicates that this agent provides excellent delineation of the stomach and duodenum from contiguous viscera. Distal small bowel visualization is less predictabel. Further clinical trials should confirm the utility of this solution, which contains a combination of iron salts and paramagnetic metallic ions. (orig.)

  20. Current status of superparamagnetic iron oxide contrast agents for liver magnetic resonance imaging.

    Science.gov (United States)

    Wang, Yi-Xiang J

    2015-12-21

    Five types of superparamagnetic iron oxide (SPIO), i.e. Ferumoxides (Feridex(®) IV, Berlex Laboratories), Ferucarbotran (Resovist(®), Bayer Healthcare), Ferumoxtran-10 (AMI-227 or Code-7227, Combidex(®), AMAG Pharma; Sinerem(®), Guerbet), NC100150 (Clariscan(®), Nycomed,) and (VSOP C184, Ferropharm) have been designed and clinically tested as magnetic resonance contrast agents. However, until now Resovist(®) is current available in only a few countries. The other four agents have been stopped for further development or withdrawn from the market. Another SPIO agent Ferumoxytol (Feraheme(®)) is approved for the treatment of iron deficiency in adult chronic kidney disease patients. Ferumoxytol is comprised of iron oxide particles surrounded by a carbohydrate coat, and it is being explored as a potential imaging approach for evaluating lymph nodes and certain liver tumors.

  1. Hyperintense acute reperfusion marker is associated with higher contrast agent dosage in acute ischaemic stroke

    Energy Technology Data Exchange (ETDEWEB)

    Ostwaldt, Ann-Christin; Schaefer, Tabea; Villringer, Kersten; Fiebach, Jochen B. [Charite Universitaetsmedizin Berlin, Academic Neuroradiology, Center for Stroke Research Berlin (CSB), Berlin (Germany); Rozanski, Michal; Ebinger, Martin [Charite Universitaetsmedizin Berlin, Academic Neuroradiology, Center for Stroke Research Berlin (CSB), Berlin (Germany); Charite Universitaetsmedizin, Department of Neurology, Berlin (Germany); Jungehuelsing, Gerhard J. [Stiftung des Buergerlichen Rechts, Juedisches Krankenhaus Berlin, Berlin (Germany)

    2015-11-15

    The hyperintense acute reperfusion marker (HARM) on fluid-attenuated inversion recovery (FLAIR) images is associated with blood-brain barrier (BBB) permeability changes. The aim of this study was to examine the influence of contrast agent dosage on HARM incidence in acute ischaemic stroke patients. We prospectively included 529 acute ischaemic stroke patients (204 females, median age 71 years). Patients underwent a first stroke-MRI within 24 hours from symptom onset and had a follow-up on day 2. The contrast agent Gadobutrol was administered to the patients for perfusion imaging or MR angiography. The total dosage was calculated as ml/kg body weight and ranged between 0.04 and 0.31 mmol/kg on the first examination. The incidence of HARM was evaluated on day 2 FLAIR images. HARM was detected in 97 patients (18.3 %). HARM incidence increased significantly with increasing dosages of Gadobutrol. Also, HARM positive patients were significantly older. HARM was not an independent predictor of worse clinical outcome, and we did not find an association with increase risk of haemorrhagic transformation. A higher dosage of Gadobutrol in acute stroke patients on initial MRI is associated with increased HARM incidence on follow-up. MRI studies on BBB should therefore standardize contrast agent dosages. (orig.)

  2. The fabrication of novel nanobubble ultrasound contrast agent for potential tumor imaging

    Energy Technology Data Exchange (ETDEWEB)

    Xing Zhanwen; Ke Hengte; Yue Xiuli; Dai Zhifei [Nanobiotechnology Division, State Key Laboratory of Urban Water Resources and Environment, School of Sciences, Harbin Institute of Technology, Harbin 150080 (China); Wang Jinrui; Zhao Bo [Department of Ultrasonography, Peking University Third Hospital, Beijing 100083 (China); Liu Jibin, E-mail: zhifei.dai@hit.edu.cn, E-mail: ji-bin.liu@jefferson.edu [Ultrasound Research and Education Institute, Thomas Jefferson University, Philadelphia, PA 19107 (United States)

    2010-04-09

    Novel biocompatible nanobubbles were fabricated by ultrasonication of a mixture of Span 60 and polyoxyethylene 40 stearate (PEG40S) followed by differential centrifugation to isolate the relevant subpopulation from the parent suspensions. Particle sizing analysis and optical microscopy inspection indicated that the freshly generated micro/nanobubble suspension was polydisperse and the size distribution was bimodal with large amounts of nanobubbles. To develop a nano-sized contrast agent that is small enough to leak through tumor pores, a fractionation to extract smaller bubbles by variation in the time of centrifugation at 20g (relative centrifuge field, RCF) was suggested. The results showed that the population of nanobubbles with a precisely controlled mean diameter could be sorted from the initial polydisperse suspensions to meet the specified requirements. The isolated bubbles were stable over two weeks under the protection of perfluoropropane gas. The acoustic behavior of the nano-sized contrast agent was evaluated using power Doppler imaging in a normal rabbit model. An excellent power Doppler enhancement was found in vivo renal imaging after intravenous injection of the obtained nanobubbles. Given the broad spectrum of potential clinical applications, the nano-sized contrast agent may provide a versatile adjunct for ultrasonic imaging enhancement and/or treatment of tumors.

  3. The fabrication of novel nanobubble ultrasound contrast agent for potential tumor imaging

    International Nuclear Information System (INIS)

    Xing Zhanwen; Ke Hengte; Yue Xiuli; Dai Zhifei; Wang Jinrui; Zhao Bo; Liu Jibin

    2010-01-01

    Novel biocompatible nanobubbles were fabricated by ultrasonication of a mixture of Span 60 and polyoxyethylene 40 stearate (PEG40S) followed by differential centrifugation to isolate the relevant subpopulation from the parent suspensions. Particle sizing analysis and optical microscopy inspection indicated that the freshly generated micro/nanobubble suspension was polydisperse and the size distribution was bimodal with large amounts of nanobubbles. To develop a nano-sized contrast agent that is small enough to leak through tumor pores, a fractionation to extract smaller bubbles by variation in the time of centrifugation at 20g (relative centrifuge field, RCF) was suggested. The results showed that the population of nanobubbles with a precisely controlled mean diameter could be sorted from the initial polydisperse suspensions to meet the specified requirements. The isolated bubbles were stable over two weeks under the protection of perfluoropropane gas. The acoustic behavior of the nano-sized contrast agent was evaluated using power Doppler imaging in a normal rabbit model. An excellent power Doppler enhancement was found in vivo renal imaging after intravenous injection of the obtained nanobubbles. Given the broad spectrum of potential clinical applications, the nano-sized contrast agent may provide a versatile adjunct for ultrasonic imaging enhancement and/or treatment of tumors.

  4. The fabrication of novel nanobubble ultrasound contrast agent for potential tumor imaging

    Science.gov (United States)

    Xing, Zhanwen; Wang, Jinrui; Ke, Hengte; Zhao, Bo; Yue, Xiuli; Dai, Zhifei; Liu, Jibin

    2010-04-01

    Novel biocompatible nanobubbles were fabricated by ultrasonication of a mixture of Span 60 and polyoxyethylene 40 stearate (PEG40S) followed by differential centrifugation to isolate the relevant subpopulation from the parent suspensions. Particle sizing analysis and optical microscopy inspection indicated that the freshly generated micro/nanobubble suspension was polydisperse and the size distribution was bimodal with large amounts of nanobubbles. To develop a nano-sized contrast agent that is small enough to leak through tumor pores, a fractionation to extract smaller bubbles by variation in the time of centrifugation at 20g (relative centrifuge field, RCF) was suggested. The results showed that the population of nanobubbles with a precisely controlled mean diameter could be sorted from the initial polydisperse suspensions to meet the specified requirements. The isolated bubbles were stable over two weeks under the protection of perfluoropropane gas. The acoustic behavior of the nano-sized contrast agent was evaluated using power Doppler imaging in a normal rabbit model. An excellent power Doppler enhancement was found in vivo renal imaging after intravenous injection of the obtained nanobubbles. Given the broad spectrum of potential clinical applications, the nano-sized contrast agent may provide a versatile adjunct for ultrasonic imaging enhancement and/or treatment of tumors.

  5. Synthesis of functionalized magnetite nanoparticles to use as liver targeting MRI contrast agent

    International Nuclear Information System (INIS)

    Yazdani, Farshad; Fattahi, Bahare; Azizi, Najmodin

    2016-01-01

    The aim of this research was the preparation of functionalized magnetite nanoparticles to use as a liver targeting contrast agent in magnetic resonance imaging (MRI). For this purpose, Fe_3O_4 nanoparticles were synthesized via the co-precipitation method. The synthesized nanoparticles were coated with silica via the Stober method and finally the coated nanoparticles were functionalized with mebrofenin. Formation of crystalline magnetite particles was confirmed by X-ray diffraction (XRD) analysis. The Fourier transform infrared spectroscopy (FTIR) and energy dispersive X-ray analyzer (EDX) of the final product showed that silica had been effectively bonded onto the surface of the magnetite nanoparticles and the coated nanoparticles functionalized with mebrofenin. The magnetic resonance imaging of the functional nanoparticles showed that the Fe_3O_4–SiO_2-mebrofenin composite is an effective MRI contrast agent for liver targeting. - Highlights: • Superparamagnetic magnetite nanoparticles have been synthesized by simple and economical method. • Preperation of functional MNPs as a MRI contrast agent for liver targeting. • Gaining a good r_2 relaxivity of the coated functional nanoparticles.

  6. Synthesis and characterization of superparamagnetic iron oxide nanoparticles as calcium-responsive MRI contrast agents

    International Nuclear Information System (INIS)

    Xu, Pengfei; Shen, Zhiwei; Zhang, Baolin; Wang, Jun; Wu, Renhua

    2016-01-01

    Highlights: • SPIONs were conjugated with EGTA by EDC/sulfo-NHS method. • The presence of Ca"2"+ induced the aggregation of EGTA-SPIONs. • The aggregation of EGTA-SPIONs increased the T2 relaxation time. • EGTA-SPIONs can be used for the calcium imaging with MRI. - Abstract: Superparamagnetic iron oxide nanoparticles (SPIONs) as T2 contrast agents have great potential to sense calcium ion (Ca"2"+) using magnetic resonance imaging (MRI). Here we prepared calcium-responsive SPIONs for MRI, formed by combining poly(ethylene glycol) (PEG) and polyethylenimine (PEI) coated iron oxide nanoparticle (PEI/PEG-SPIONs) contrast agents with the straightforward calcium-sensing compound EGTA (ethylene glycol tetraacetic acid). EGTA was conjugated onto PEI/PEG-SPIONs using EDC/sulfo-NHS method. EGTA-SPIONs were characterized using TEM, XPS, DSL, TGA and SQUIID. DSL results show that the SPIONs aggregate in the presence of Ca"2"+. MRI analyses indicate that the water proton T2 relaxation rates in HEPES suspensions of the EGTA-SPIONs significantly increase with the calcium concentration because the SPIONs aggregate in the presence of Ca"2"+. The T2 values decreased 25% when Ca"2"+ concentration decreased from 1.2 to 0.8 mM. The aggregation of EGTA-SPIONs could be reversed by EDTA. EGTA-SPIONs have potential as smart contrast agents for Ca"2"+-sensitive MRI.

  7. PEGylated chitosan grafted with polyamidoaminedendron as tumor-targeted magnetic resonance imaging contrast agent

    International Nuclear Information System (INIS)

    Guangyue Zu; Xiaoyan Tong; Yi Cao; Ye Kuang; Yajie Zhang; Min Liu; Renjun Pei

    2017-01-01

    Macromolecular contrast agents labeled with targeting ligands are now receiving growing interest in tumor-targeted magnetic resonance imaging. In this study, a macromolecular contrast agent based on PEGylated chitosan was synthesized and characterized, and its application as an MRI contrast agent was then demonstrated both in vitro and in vivo. First, the chitosan backbone was partially grafted with poly(ethylene glycol), which was used to improve the in vivo stability, followed by modifying with azide groups. Second, alkynyl-terminated PAMAM dendron modified with gadolinium diethylenetriaminepentaacetic acid (Gd-DTPA) was synthesized and conjugated onto the chitosan backbone through click chemistry. Finally, the obtained mCA was further functionalized with folic acid to improve the target specificity. The obtained FA labeled mCA exhibited higher relaxivity (9.53 mM"-"1.s"-"1) relative to Gd-DTPA (4.25 mM"-"1.s"-"1) and showed negligible toxicity as determined by the WST assay. In vivo MRI results suggested that a relatively high signal enhancement was observed in the tumor region, which made it a promising candidate for tumor-targeted MRI CA. (authors)

  8. Longitudinal study of iodine in toenails following IV administration of an iodine-containing contrast agent

    International Nuclear Information System (INIS)

    Spate, V.L.; Morris, J.S.; Nichols, T.A.; Baskett, C.K.; Mason, M.M.; Horsman, T.L.; McDougall, I.R.

    1998-01-01

    The literature on the relationship between diet and thyroid cancer (TC) risk and the higher incidence of TC among Asian immigrants to the US compared to second and third generation subgroups has prompted epidemiologists to hypothesize that increased levels of iodine consumption may be associated with TC risk, particularly among persons with a history of clinical or subclinical thyroid dysfunction. At the University of Missouri Research Reactor (MURR), we have applied epiboron neutron activation analysis to investigate human nails as a dietary monitor for iodine. Preliminary studies have indicated a positive correlation between dietary iodine intake and the concentration of iodine in toenails. However, these studies are confounded by high iodine levels (up to 30 ppm) in approximately 5% of the nails studied. We hypothesize that, in the subjects we have studied, the high iodine levels may be due to iodine-containing medications, in particular contrast-agents containing iopamidol. This paper will report on longitudinal studies using contrast agent subjects who where followed-up for almost two years compared to a longitudinal control and a population mean. Based on this study, we suggest that iodine-containing contrast agents contaminate nail samples via non-specific binding in the short term followed by incorporation in the nail as a result of absorption. (author)

  9. ESGAR consensus statement on liver MR imaging and clinical use of liver-specific contrast agents

    Energy Technology Data Exchange (ETDEWEB)

    Neri, E.; Boraschi, P.; Bartolozzi, C. [University of Pisa, Department of Diagnostic and Interventional Radiology, Pisa (Italy); Bali, M.A.; Matos, C. [Hopital Erasme, MRI Clinics, Department of Radiology, Bruxelles (Belgium); Ba-Ssalamah, A. [The General Hospital of the Medical University of Vienna, Department of Biomedical Imaging and Image-guided Therapy, Vienna (Austria); Brancatelli, G. [University of Palermo, Department of Radiology, Palermo (Italy); Alves, F.C. [University Hospital of Coimbra, Medical Imaging Department and Faculty of Medicine, Coimbra (Portugal); Grazioli, L. [Spedali Civili di Brescia, Department of Radiology, Brescia (Italy); Helmberger, T. [Academic Teaching Hospital of the Technical University, Department of Diagnostic and Interventional Radiology and Nuclear Medicine, Klinikum Bogenhausen, Munich (Germany); Lee, J.M. [Seoul National University College of Medicine, Division of Abdominal Imaging, Department of Radiology, Seoul (Korea, Republic of); Manfredi, R. [University of Verona, Department of Radiology, Verona (Italy); Marti-Bonmati, L. [Hospital Universitario y Politecnico La Fe, Area Clinica de Imagen Medica, Valencia (Spain); Merkle, E.M. [Universitaetsspital Basel, Klinik fuer Radiologie und Nuklearmedizin, Basel (Switzerland); Op De Beeck, B. [Antwerp University Hospital, Department of Radiology, Edegem (Belgium); Schima, W. [KH Goettlicher Heiland, Krankenhaus der Barmherzigen Schwestern and Sankt Josef-Krankenhaus, Department of Diagnostic and Interventional Radiology, Vienna (Austria); Skehan, S. [St Vincent' s University Hospital, Department of Radiology, Dublin (Ireland); Vilgrain, V. [Assistance Publique-Hopitaux de Paris, APHP, Hopital Beaujon, Radiology Department, Clichy, Paris (France); Zech, C. [Universitaetsspital Basel, Abteilungsleiter Interventionelle Radiologie, Klinik fuer Radiologie und Nuklearmedizin, Basel (Switzerland)

    2016-04-15

    To develop a consensus and provide updated recommendations on liver MR imaging and the clinical use of liver-specific contrast agents. The European Society of Gastrointestinal and Abdominal Radiology (ESGAR) formed a multinational European panel of experts, selected on the basis of a literature review and their leadership in the field of liver MR imaging. A modified Delphi process was adopted to draft a list of statements. Descriptive and Cronbach's statistics were used to rate levels of agreement and internal reliability of the consensus. Three Delphi rounds were conducted and 76 statements composed on MR technique (n = 17), clinical application of liver-specific contrast agents in benign, focal liver lesions (n = 7), malignant liver lesions in non-cirrhotic (n = 9) and in cirrhotic patients (n = 18), diffuse and vascular liver diseases (n = 12), and bile ducts (n = 13). The overall mean score of agreement was 4.84 (SD ±0.17). Full consensus was reached in 22 % of all statements in all working groups, with no full consensus reached on diffuse and vascular diseases. The consensus provided updated recommendations on the methodology, and clinical indications, of MRI with liver specific contrast agents in the study of liver diseases. (orig.)

  10. Computed tomography enterography: a comparison of different neutral oral contrast agents

    International Nuclear Information System (INIS)

    D'Ippolito, Giuseppe; Braga, Fernanda Angeli; Resende, Marcelo Cardoso; Bretas, Elisa Almeida Sathler; Nunes, Thiago Franchi; Rosas, George de Queiroz; Tiferes, Dario Arie

    2012-01-01

    Objective: The purpose of this study was to assess the performance of neutral oral contrast agents, comparing intestinal distension, distinction of intestinal wall, acceptance and side effects. Materials and Methods: Prospective, randomized, and double-blinded study involving 30 patients who underwent computed tomography of abdomen and pelvis with administration of neutral oral contrast agents, divided into three groups according the contrast agent type: milk, water, and polyethylene glycol. The images were consensually analyzed by two observers, considering the degree of bowel distension and intestinal wall distinction. The patients responded to a questionnaire regarding the taste of the ingested solution and on their side effects. Kruskal-Wallis and chi-square tests were employed for statistical analysis. Results: Among 40 studied intestinal segments, appropriate bowel distension (intestinal loop diameter > 2 cm) was observed in 14 segments (35%) in the milk group, 10 segments (25%) in the water group and 23 segments (57%) in the polyethylene glycol group (p = 0.01). Preparation with polyethylene glycol resulted in the best bowel distension, but it presented the worst taste and highest incidence of diarrhea as reported by patients. Conclusion: Bowel preparation with oral polyethylene glycol results in higher degree of bowel distension than with water or milk, but presents worst acceptance related to its taste and frequency of diarrhea as a side effect. (author)

  11. Computed tomography enterography: a comparison of different neutral oral contrast agents

    Energy Technology Data Exchange (ETDEWEB)

    D' Ippolito, Giuseppe, E-mail: giuseppe_dr@uol.com.br [Department of Imaging Diagnosis, Universidade Federal de Sao Paulo (UNIFESP), Sao Paulo, SP (Brazil); Braga, Fernanda Angeli; Resende, Marcelo Cardoso; Bretas, Elisa Almeida Sathler; Nunes, Thiago Franchi; Rosas, George de Queiroz; Tiferes, Dario Arie [Abdominal Imaging Section, Department of Imaging Diagnosis - Universidade Federal de Sao Paulo (Unifesp), Sao Paulo, SP (Brazil)

    2012-05-15

    Objective: The purpose of this study was to assess the performance of neutral oral contrast agents, comparing intestinal distension, distinction of intestinal wall, acceptance and side effects. Materials and Methods: Prospective, randomized, and double-blinded study involving 30 patients who underwent computed tomography of abdomen and pelvis with administration of neutral oral contrast agents, divided into three groups according the contrast agent type: milk, water, and polyethylene glycol. The images were consensually analyzed by two observers, considering the degree of bowel distension and intestinal wall distinction. The patients responded to a questionnaire regarding the taste of the ingested solution and on their side effects. Kruskal-Wallis and chi-square tests were employed for statistical analysis. Results: Among 40 studied intestinal segments, appropriate bowel distension (intestinal loop diameter > 2 cm) was observed in 14 segments (35%) in the milk group, 10 segments (25%) in the water group and 23 segments (57%) in the polyethylene glycol group (p = 0.01). Preparation with polyethylene glycol resulted in the best bowel distension, but it presented the worst taste and highest incidence of diarrhea as reported by patients. Conclusion: Bowel preparation with oral polyethylene glycol results in higher degree of bowel distension than with water or milk, but presents worst acceptance related to its taste and frequency of diarrhea as a side effect. (author)

  12. Synthesis and characterization of superparamagnetic iron oxide nanoparticles as calcium-responsive MRI contrast agents

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Pengfei [State Key Laboratory Breeding Base of Nonferrous Metals and Specific Materials Processing, School of Materials Science and Engineering, Guilin University of Technology, Jian Gan Road 12, Guilin 541004 (China); Shen, Zhiwei [Second Affiliated Hospital of Shantou University Medical College, Dong Xia North Road, Shantou 515041,China (China); Zhang, Baolin, E-mail: baolinzhang@ymail.com [State Key Laboratory Breeding Base of Nonferrous Metals and Specific Materials Processing, School of Materials Science and Engineering, Guilin University of Technology, Jian Gan Road 12, Guilin 541004 (China); Wang, Jun [State Key Laboratory Breeding Base of Nonferrous Metals and Specific Materials Processing, School of Materials Science and Engineering, Guilin University of Technology, Jian Gan Road 12, Guilin 541004 (China); Wu, Renhua, E-mail: rhwu@stu.edu.cn [Second Affiliated Hospital of Shantou University Medical College, Dong Xia North Road, Shantou 515041,China (China)

    2016-12-15

    Highlights: • SPIONs were conjugated with EGTA by EDC/sulfo-NHS method. • The presence of Ca{sup 2+} induced the aggregation of EGTA-SPIONs. • The aggregation of EGTA-SPIONs increased the T2 relaxation time. • EGTA-SPIONs can be used for the calcium imaging with MRI. - Abstract: Superparamagnetic iron oxide nanoparticles (SPIONs) as T2 contrast agents have great potential to sense calcium ion (Ca{sup 2+}) using magnetic resonance imaging (MRI). Here we prepared calcium-responsive SPIONs for MRI, formed by combining poly(ethylene glycol) (PEG) and polyethylenimine (PEI) coated iron oxide nanoparticle (PEI/PEG-SPIONs) contrast agents with the straightforward calcium-sensing compound EGTA (ethylene glycol tetraacetic acid). EGTA was conjugated onto PEI/PEG-SPIONs using EDC/sulfo-NHS method. EGTA-SPIONs were characterized using TEM, XPS, DSL, TGA and SQUIID. DSL results show that the SPIONs aggregate in the presence of Ca{sup 2+}. MRI analyses indicate that the water proton T2 relaxation rates in HEPES suspensions of the EGTA-SPIONs significantly increase with the calcium concentration because the SPIONs aggregate in the presence of Ca{sup 2+}. The T2 values decreased 25% when Ca{sup 2+} concentration decreased from 1.2 to 0.8 mM. The aggregation of EGTA-SPIONs could be reversed by EDTA. EGTA-SPIONs have potential as smart contrast agents for Ca{sup 2+}-sensitive MRI.

  13. Safety assessment of nanoparamagnetic contrast agents with different coatings for molecular MRI

    Science.gov (United States)

    Azizian, Gholamreza; Riyahi-Alam, Nader; Haghgoo, Soheila; Saffari, Mojtaba; Zohdiaghdam, Reza; Gorji, Ensieh

    2013-04-01

    Despite the wide application of gadolinium as a contrast agent for magnetic resonance imaging (MRI), there is a serious lack of information on its toxicity. Gadolinium and gadolinium oxide (Gd-oxide) are used as contrast agents for magnetic resonance imaging (MRI). There are methods for reducing toxicity of these materials, such as core nanoparticles coating or conjugating. Therefore, for toxicity evaluation, we compared the viability of commercial contrast agents in MRI (Gd-DTPA) and three nanoparticles with the same core Gd2O3 and small particulate gadolinium oxide or SPGO (DTPA. The MTT and LDH assay results showed that Gd2O3-DEG nanoparticles were more toxic than Gd-DTPA and other nanoparticles. Also, SPGO-mPEG-silane2000 was more biocompatible than other nanoparticles. The obtained results did not show any significant increase in cytotoxicity of the nanoparticles and Gd-DTPA, neither dose-dependent nor time-dependent. Therefore, DEG and PEG, due to their considerable properties and irregular sizes (different molecular weights), were selected as the useful surface covering materials of nanomagnetic particles that could reveal noticeable relaxivity and biocompatibility characteristics.

  14. SU-F-T-664: The Efficacy of Gold Nanoparticles as Contrast Agents in Mice

    Energy Technology Data Exchange (ETDEWEB)

    Yuan, Y; Zhang, Y; Sajo, E [University of Massachusetts Lowell, Lowell, MA (United States); Yasmin-Karim, S; Karve, A [Brigham and Women’s Hospital, Dana-Farber Cancer Institute and Harvard Medical School, Boston, MA (United States); Ngwa, W [University of Massachusetts Lowell, Lowell, MA (United States); Brigham and Women’s Hospital, Dana-Farber Cancer Institute and Harvard Medical School, Boston, MA (United States)

    2016-06-15

    Purpose: Micro-Computed Tomography (micro-CT) has been widely used as a non-invasive, high-resolution imaging modality in preclinical research. However, tumors cannot be well distinguished, since their density are similar to those of surrounding tissues, and the tumors’ natural contrast is very low. The benefits of using Gold Nanoparticles (AuNPs) as a promising high atomic weight contrast agent have been published in recent years. The aim of this study is to investigate the efficacy of AuNPs as contrast agents using different energy x-rays. Methods: The left flank of an immune-compromised athymic nude mouse was implanted with subcutaneous xenograft model of human lung cancer line, A549 cells (from ATCC). After 14 days, this mouse was imaged with dual energy cone-beam micro-CT. The selected energies were 45 kVp and 65 kVp. 10µg AuNPs (200 µg/ml concentration) approximately 12 nm in size were injected subcutaneously into the tumor. The mouse was imaged 0, 3 and 24 hours post-injection. During scanning, this mouse was anesthetized. All projection raw data have been optimized and then images were reconstructed with the FDK Algorithm. Results: Based on images, at 0 hour, AuNPs provided obvious contrast no matter which energy selected, 45 kVp or 65 kVp; and using 45 kVp X-ray, AuNps showed greater contrast. After 3 hours or evenand longer, AuNPs distributed throughout the whole body of mouse, and they were not shown clearly shown in the images. Conclusion: In this study, we investigated the efficacy of AuNPs as image contrast agents at different energies with dual-energy micro-CT, using 200µg/mL of AuNPs. Sufficiently high concentrations of AuNPs are needed to be able to track intratumoral distribution. Images showed good contrast immediately following the administration of the agent but results were poor after 3 hours.

  15. High spatial resolution and high contrast visualization of brain arteries and veins. Impact of blood pool contrast agent and water-selective excitation imaging at 3T

    International Nuclear Information System (INIS)

    Spuentrup, E.; Jacobs, J.E.; Kleimann, J.F.

    2010-01-01

    Purpose: To investigate a blood pool contrast agent and water-selective excitation imaging at 3 T for high spatial and high contrast imaging of brain vessels including the veins. Methods and Results: 48 clinical patients (47 ± 18 years old) were included. Based on clinical findings, twenty-four patients received a single dose of standard extracellular Gadoterate-meglumine (Dotarem registered ) and 24 received the blood pool contrast agent Gadofosveset (Vasovist registered ). After finishing routine MR protocols, all patients were investigated with two high spatial resolution (0.15 mm 3 voxel size) gradient echo sequences in random order in the equilibrium phase (steady-state) as approved by the review board: A standard RF-spoiled gradient-echo sequence (HR-SS, TR/TE 5.1 / 2.3 msec, FA 30 ) and a fat-suppressed gradient-echo sequence with water-selective excitation (HR-FS, 1331 binominal-pulse, TR/TE 8.8 / 3.8 msec, FA 30 ). The images were subjectively assessed (image quality with vessel contrast, artifacts, depiction of lesions) by two investigators and contrast-to-noise ratios (CNR) were compared using the Student's t-test. The image quality and CNR in the HR-FS were significantly superior compared to the HR-SS for both contrast agents (p < 0.05). The CNR was also improved when using the blood pool agent but only to a minor extent while the subjective image quality was similar for both contrast agents. Conclusion: The utilized sequence with water-selective excitation improved image quality and CNR properties in high spatial resolution imaging of brain arteries and veins. The used blood pool contrast agent improved the CNR only to a minor extent over the extracellular contrast agent. (orig.)

  16. Dynamic manipulation of the subharmonic scattering of phospholipid-coated microbubbles

    Energy Technology Data Exchange (ETDEWEB)

    Faez, Telli; Renaud, Guillaume; De Jong, Nico [Biomedical Engineering Thoraxcenter, Erasmus Medical Center, PO Box 2040, 3000 CA Rotterdam (Netherlands); Defontaine, Marielle; Calle, Samuel, E-mail: t.faez@erasmusmc.nl [INSERM U930-CNRS ERL3106, Universite Francois Rabelais, UFR Medecine, 10 bd Tonnelle, 37000 Tours (France)

    2011-10-07

    In this paper, the influence of a dynamic variation in the ambient pressure on the subharmonic response of phospholipid-coated microbubbles was investigated. The ambient pressure in water was modulated by a 2.5 kHz acoustic wave with a peak amplitude of 15 kPa. We investigated the fundamental and subharmonic emissions at two driving frequencies: 5 and 10 MHz. The modulation of the bubble radius induced by the dynamic variation in the liquid ambient pressure subsequently causes modulations of the scattered acoustic pressure at the fundamental and subharmonic frequencies (half the fundamental frequency). As a first result, we measured that the variation in the ambient pressure of 15 kPa can modulate the subharmonic amplitude up to 10 dB as compared to the static atmospheric pressure condition. As a second result, we noticed that the relative subharmonic amplitude modulation as a function of the LF acoustic pressure was symmetrical for the 5 MHz driving frequency but asymmetric for 10 MHz. In the latter case, the subharmonic amplitude was more enhanced for an ambient overpressure than reduced for an ambient depression of the same amplitude likely due to the buckling of the lipid shell. However, the fundamental amplitude was symmetrically modulated during bubble compression and expansion. Moreover, subharmonic and fundamental amplitude modulations were found to be either in phase or out of phase with the low-frequency acoustic pressure. Numerical simulations showed that this behavior can be obtained depending on the bubbles' diameter. The highest subharmonic amplitude was measured when microbubbles were insonified at 10 MHz. This fact together with the asymmetry observed in the subharmonic modulation suggests that smaller bubbles with a buckling shell are excited at 10 MHz compared to 5 MHz. These results present new potentials for in vitro characterization of contrast agent microbubbles and possibly a new imaging modality.

  17. Magnetic resonance imaging of osteosarcoma using a bis(alendronate)-based bone-targeted contrast agent.

    Science.gov (United States)

    Ge, Pingju; Sheng, Fugeng; Jin, Yiguang; Tong, Li; Du, Lina; Zhang, Lei; Tian, Ning; Li, Gongjie

    2016-12-01

    Magnetic resonance (MR) is currently used for diagnosis of osteosarcoma but not well even though contrast agents are administered. Here, we report a novel bone-targeted MR imaging contrast agent, Gd 2 -diethylenetriaminepentaacetate-bis(alendronate) (Gd 2 -DTPA-BA) for the diagnosis of osteosarcoma. It is the conjugate of a bone cell-seeking molecule (i.e., alendronate) and an MR imaging contrast agent (i.e., Gd-DTPA). Its physicochemical parameters were measured, including pK a , complex constant, and T 1 relaxivity. Its bone cell-seeking ability was evaluated by measuring its adsorption on hydroxyapatite. Hemolysis was investigated. MR imaging and biodistribution of Gd 2 -DTPA-BA and Gd-DTPA were studied on healthy and osteosarcoma-bearing nude mice. Gd 2 -DTPA-BA showed high adsorption on hydroxyapatite, the high MR relaxivity (r 1 ) of 7.613mM -1 s -1 (2.6 folds of Gd-DTPA), and no hemolysis. The MR contrast effect of Gd 2 -DTPA-BA was much higher than that of Gd-DTPA after intravenous injection to the mice. More importantly, the MR imaging of osteosarcoma was significantly improved by Gd 2 -DTPA-BA. The signal intensity of Gd 2 -DTPA-BA reached 120.3% at 50min, equal to three folds of Gd-DTPA. The bone targeting index (bone/blood) of Gd 2 -DTPA-BA in the osteosarcoma-bearing mice was very high to 130 at 180min. Furthermore, the contrast enhancement could also be found in the lung due to metastasis of osteosarcoma. Gd 2 -DTPA-BA plays a promising role in the diagnoses of osteosacomas, including the primary bone tumors and metastases. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  18. Intravenous, contrast-enhanced MR colonography using air as endoluminal contrast agent: Impact on colorectal polyp detection.

    LENUS (Irish Health Repository)

    Keeling, Aoife N

    2012-02-01

    PURPOSE: To compare diagnostic accuracy and patient tolerance of MR colonography with intravenous contrast and luminal air (MRC) to conventional colonoscopy (CC). MATERIALS AND METHODS: IRB approval and written informed consent were obtained. Forty-six patients, both screening and symptomatic, underwent MRC followed by CC. The MRC technique employed 3D T1W spoiled gradient echo sequences performed after the administration of gadopenetate dimeglumine, with parallel imaging. The diagnostic accuracy and tolerance of patients for MRC was compared to CC. RESULTS: Twenty-four polyps were detected in eighteen patients with CC (5 polyps >\\/=10mm, 4 polyps 6-9mm, 15 polyps <\\/=5mm). MRC was 66.7% (12\\/18) sensitive and 96.4% (27\\/28) specific for polyp detection on a per-patient basis. When analyzed by polyp size, sensitivity and specificity of MRC was 100% (5\\/5) and 100% (19\\/19), respectively, for lesions greater than 10mm, 100% (4\\/4) and 100% (20\\/20) for lesions 6-9mm, and sensitivity of 20% (3\\/15) lesions less than 5mm. The sensitivity and specificity of MRC for detecting significant lesions (>6mm) was 100% (9\\/9) and 100% (15\\/15), respectively. Regarding tolerance of the exams, there were no significant differences between MRC and CC. Thirty-five percent (n=16) of patients preferred MRC as a future screening test compared to 33% (n=15) for CC. CONCLUSION: MRC using air as an intraluminal contrast agent is a feasible and well-tolerated technique for detecting colonic polyps >\\/=6mm in size. Further studies are warranted.

  19. Intravenous, contrast-enhanced MR colonography using air as endoluminal contrast agent: Impact on colorectal polyp detection.

    LENUS (Irish Health Repository)

    Keeling, Aoife N

    2010-12-03

    PURPOSE: To compare diagnostic accuracy and patient tolerance of MR colonography with intravenous contrast and luminal air (MRC) to conventional colonoscopy (CC). MATERIALS AND METHODS: IRB approval and written informed consent were obtained. Forty-six patients, both screening and symptomatic, underwent MRC followed by CC. The MRC technique employed 3D T1W spoiled gradient echo sequences performed after the administration of gadopenetate dimeglumine, with parallel imaging. The diagnostic accuracy and tolerance of patients for MRC was compared to CC. RESULTS: Twenty-four polyps were detected in eighteen patients with CC (5 polyps ≥10mm, 4 polyps 6-9mm, 15 polyps ≤5mm). MRC was 66.7% (12\\/18) sensitive and 96.4% (27\\/28) specific for polyp detection on a per-patient basis. When analyzed by polyp size, sensitivity and specificity of MRC was 100% (5\\/5) and 100% (19\\/19), respectively, for lesions greater than 10mm, 100% (4\\/4) and 100% (20\\/20) for lesions 6-9mm, and sensitivity of 20% (3\\/15) lesions less than 5mm. The sensitivity and specificity of MRC for detecting significant lesions (>6mm) was 100% (9\\/9) and 100% (15\\/15), respectively. Regarding tolerance of the exams, there were no significant differences between MRC and CC. Thirty-five percent (n=16) of patients preferred MRC as a future screening test compared to 33% (n=15) for CC. CONCLUSION: MRC using air as an intraluminal contrast agent is a feasible and well-tolerated technique for detecting colonic polyps ≥6mm in size. Further studies are warranted.

  20. Evaluation of date syrup as an oral negative contrast agent for MRCP.

    Science.gov (United States)

    Govindarajan, Arunkumar; Lakshmanan, Prakash Manikka; Sarawagi, Radha; Prabhakaran, Velu

    2014-11-01

    The purpose of this study was to compare the in vitro effects of date syrup with those of other contrast agents by qualitative and quantitative analysis and in vivo evaluation of the use of date syrup to improve the quality of MRCP images. Phantoms containing date syrup, ferumoxsil, pineapple juice, and water were imaged by 1.5-T MRI with T2-weighted and MRCP sequences, and signal-to-noise ratios were calculated. Biochemical analysis of date syrup was performed to find the nature of iron in it, and the iron content was quantified by energy-dispersive x-ray spectroscopy. Sixty patients underwent MRCP before and 30 minutes after ingestion of 100 mL of date syrup. Unenhanced and contrast-enhanced images were scored for gastrointestinal tract signal suppression and visualization of various pancreaticobiliary structures. In vitro evaluation showed that images obtained with date syrup had a signal-to-noise ratio comparable to that of images obtained with ferumoxsil in T2-weighted and MRCP sequences. The iron concentration in date syrup was 2.6 mg/dL, and it was in ferric form. Images obtained after oral contrast administration had statistically significant improvement in gastrointestinal tract signal suppression (p Date syrup can be used as a negative oral contrast agent for gastrointestinal tract signal suppression during MRCP and for improving visualization of various pancreaticobiliary structures.

  1. EXCI-CEST: Exploiting pharmaceutical excipients as MRI-CEST contrast agents for tumor imaging.

    Science.gov (United States)

    Longo, Dario Livio; Moustaghfir, Fatima Zzahra; Zerbo, Alexandre; Consolino, Lorena; Anemone, Annasofia; Bracesco, Martina; Aime, Silvio

    2017-06-15

    Chemical Exchange Saturation Transfer (CEST) approach is a novel tool within magnetic resonance imaging (MRI) that allows visualization of molecules possessing exchangeable protons with water. Many molecules, employed as excipients for the formulation of finished drug products, are endowed with hydroxyl, amine or amide protons, thus can be exploitable as MRI-CEST contrast agents. Their high safety profiles allow them to be injected at very high doses. Here we investigated the MRI-CEST properties of several excipients (ascorbic acid, sucrose, N-acetyl-d-glucosamine, meglumine and 2-pyrrolidone) and tested them as tumor-detecting agents in two different murine tumor models (breast and melanoma cancers). All the investigated molecules showed remarkable CEST contrast upon i.v. administration in the range 1-3ppm according to the type of mobile proton groups. A marked increase of CEST contrast was observed in tumor regions up to 30min post injection. The combination of marked tumor contrast enhancement and lack of toxicity make these molecules potential candidates for the diagnosis of tumors within the MRI-CEST approach. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Barium sulfate suspension as a negative oral contrast agent for MR imaging

    International Nuclear Information System (INIS)

    Li, K.C.P.; Tart, R.P.; Fitzsimmons, J.R.; Storm, B.; Mao, J.

    1989-01-01

    Proton spectroscopy with linewidth measurements and MR imaging were performed on various commercially available barium sulfate suspensions as well as inorganic sulfates and barium salts. Approximately 500 mL of 20%, 40%, 60%, and 70% wt/wt single-contrast oral barium sulfate suspensions were administered to four normal volunteers, and MR imaging was performed with both a 1.5-T and a 0.15-T MR imager. As much as 80% of the small bowel and the entire colon were well visualized with the 60% or 70% wt/wt single-contrast barium sulfate suspensions. The authors conclude that barium sulfate suspensions are useful as oral MR contrast agents

  3. In vitro and in vivo evaluation of poly(L-lactide-co glycolide)( PLGA) micro bubbles as a contrast agent

    International Nuclear Information System (INIS)

    Cui, W.; Bei, J.; Wang, S.; Zhao, Y.; Zhi, G.

    2005-01-01

    To achieve reliable and reproducible myocardial opacification after intravenous administration of echocardiographic contrast agents, this study was performed to fabricate a kind of poly(L-lactide-co-glycolide) (PLGA) micro bubbles-based contrast agent with a modified double emulsion method which incorporates and later sublimes po rogen, leaving voids capable of being filled with gas in their places. The morphology and size distribution of the micro bubbles were investigated. The porous inner structure formed in the micro bubble contrast agents were further proved by con focal laser scanning microscope (CLSM). All the results satisfied the requirements of ideal contrast agents. Acoustic measurement set-up detected the excellent scatter ability of the PLGA (70/30) micro bubbles. It demonstrated this kind of polymer-shell contrast agents could achieve efficient left ventricular opacification and the improved delineation of left ventricular endocardial borders. Especially the safe and successful myocardial opacification in close-chest dogs were observed

  4. Contrast agent comparison for three-dimensional micro-CT angiography: A cadaveric study.

    Science.gov (United States)

    Kingston, Mitchell J; Perriman, Diana M; Neeman, Teresa; Smith, Paul N; Webb, Alexandra L

    2016-07-01

    Barium sulfate and lead oxide contrast media are frequently used for cadaver-based angiography studies. These contrast media have not previously been compared to determine which is optimal for the visualisation and measurement of blood vessels. In this study, the lower limb vessels of 16 embalmed Wistar rats, and four sets of cannulae of known diameter, were injected with one of three different contrast agents (barium sulfate and resin, barium sulfate and gelatin, and lead oxide combined with milk powder). All were then scanned using micro-computed tomography (CT) angiography and 3-D reconstructions generated. The number of branching generations of the rat lower limb vessels were counted and compared between the contrast agents using ANOVA. The diameter of the contrast-filled cannulae, were measured and used to calculate the accuracy of the measurements by comparing the bias and variance of the estimates. Intra- and inter-observer reliability were calculated using intra-class correlation coefficients. There was no significant difference (mean difference [MD] 0.05; MD 95% confidence interval [CI] -0.83 to 0.93) between the number of branching generations for barium sulfate-resin and lead oxide-milk powder. Barium sulfate-resin demonstrated less bias and less variance of the estimates (MD 0.03; standard deviation [SD] 1.96 mm) compared to lead oxide-milk powder (MD 0.11; SD 1.96 mm) for measurements of contrast-filled cannulae scanned at high resolution. Barium sulfate-resin proved to be more accurate than lead oxide-milk powder for high resolution micro-CT scans and is preferred due to its non-toxicity. This technique could be applied to any embalmed specimen model. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  5. MRI contrast agent for targeting glioma: interleukin-13 labeled liposome encapsulating gadolinium-DTPA.

    Science.gov (United States)

    Liu, Xiaoli; Madhankumar, Achuthamangalam B; Miller, Patti A; Duck, Kari A; Hafenstein, Susan; Rizk, Elias; Slagle-Webb, Becky; Sheehan, Jonas M; Connor, James R; Yang, Qing X

    2016-05-01

    Detection of glioma with MRI contrast agent is limited to cases in which the blood-brain barrier (BBB) is compromised as contrast agents cannot cross the BBB. Thus, an early-stage infiltrating tumor is not detectable. Interleukin-13 receptor alpha 2 (IL-13Rα2), which has been shown to be overexpressed in glioma, can be used as a target moiety. We hypothesized that liposomes conjugated with IL-13 and encapsulating MRI contrast agent are capable of passing through an intact BBB and producing MRI contrast with greater sensitivity. The targeted MRI contrast agent was created by encapsulating Magnevist (Gd-DTPA) into liposomes conjugated with IL-13 and characterized by particle size distribution, cytotoxicity, and MRI relaxivity. MR image intensity was evaluated in the brain in normal mice post injection of Gd-DTPA and IL-13-liposome-Gd-DTPA one day apart. The specificity for glioma detection by IL-13-liposome-Gd-DTPA was demonstrated in an intracranial glioma mouse model and validated histologically. The average size of IL-13-liposome-Gd-DTPA was 137 ± 43 nm with relaxivity of 4.0 ± 0.4 L/mmole-s at 7 Tesla. No significant cytotoxicity was observed with MTS assay and serum chemistry in mice. The MRI signal intensity was enhanced up to 15% post injection of IL-13-liposome-Gd-DTPA in normal brain tissue following a similar time course as that for the pituitary gland outside of the BBB. MRI enhanced by IL-13-liposome-Gd-DTPA detected small tumor masses in addition to those seen with Magnevist-enhanced MRI. IL-13-liposome-Gd-DTPA is able to pass through the uncompromised BBB and detect an early stage glioma that cannot be seen with conventional contrast-enhanced MRI. © The Author(s) 2015. Published by Oxford University Press on behalf of the Society for Neuro-Oncology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  6. Tissue-specific MR contrast agents. Impact on imaging diagnosis and future prospects

    International Nuclear Information System (INIS)

    Yoshimitsu, Kengo; Nakayama, Tomohiro; Kakihara, Daisuke; Irie, Hiroyuki; Tajima, Tsuyoshi; Asayama, Yoshiki; Hirakawa, Masakazu; Ishigami, Kousei; Honda, Hiroshi

    2005-01-01

    Superparamagnetic iron oxide (SPIO) is the only tissue-specific MR agent currently available in Japan. It is quickly taken up by Kupffer cells at the first pass (either arterial or portal) and becomes clustered in the lysosome, providing characteristic T2 * and T2 shortening effects that suppresses the signal of normal or non-tumorous liver tissue. SPIO has dramatically changed the diagnostic algorithm of liver metastasis in clinical practice, now serving as the gold standard instead of CT during arterial portography (CTAP). Its role in the diagnosis of hepatocellular carcinoma (HCC), however, is somewhat complicated, owing to its heterogeneous uptake by the background cirrhotic liver, as well as by some of the HCCs themselves. It has been shown to be useful in the diagnosis of pseudolesions (arterioportal shunts) and some benign hepatocellular lesions (focal nodular hyperplasia or adenoma) by their complete or partial uptake of SPIO, in contrast to an absence of uptake by true liver lesions. It has also been suggested that the histological grade of HCC affects the degree of SPIO uptake. Thus, SPIO serves as a complementary tool to the primary modalities of vascular survey, namely, dynamic CT/MR and CT during hepatic arteriography (CTHA)/CTAP, in the diagnosis of HCC. Gadolinium ethoxybenzyl diethylenetriaminepentaacetic acid (Gd-EOB-DTPA) is a novel hepatobiliary contrast agent that is not yet available but is supposed to be approved by the Ministry of Health, Labour, and Welfare of Japan in the near future. It is taken up by hepatocytes and excreted into the bile, providing a T1-shortening effect that enhances the normal or non-tumorous liver tissue. It has also been shown to have the effect of positive enhancement of hypervascular liver tumors on the arterial phase, just like the usual extracellular contrast agent (gadopentetate dimeglumine: Gd-DTPA). Thus, Gd-EOB-DTPA was once thought to be an ideal contrast agent for liver tumors, providing information on both

  7. Cavitation and contrast: the use of bubbles in ultrasound imaging and therapy.

    Science.gov (United States)

    Stride, E P; Coussios, C C

    2010-01-01

    Microbubbles and cavitation are playing an increasingly significant role in both diagnostic and therapeutic applications of ultrasound. Microbubble ultrasound contrast agents have been in clinical use now for more than two decades, stimulating the development of a range of new contrast-specific imaging techniques which offer substantial benefits in echocardiography, microcirculatory imaging, and more recently, quantitative and molecular imaging. In drug delivery and gene therapy, microbubbles are being investigated/developed as vehicles which can be loaded with the required therapeutic agent, traced to the target site using diagnostic ultrasound, and then destroyed with ultrasound of higher intensity energy burst to release the material locally, thus avoiding side effects associated with systemic administration, e.g. of toxic chemotherapy. It has moreover been shown that the motion of the microbubbles increases the permeability of both individual cell membranes and the endothelium, thus enhancing therapeutic uptake, and can locally increase the activity of drugs by enhancing their transport across biologically inaccessible interfaces such as blood clots or solid tumours. In high-intensity focused ultrasound (HIFU) surgery and lithotripsy, controlled cavitation is being investigated as a means of increasing the speed and efficacy of the treatment. The aim of this paper is both to describe the key features of the physical behaviour of acoustically driven bubbles which underlie their effectiveness in biomedical applications and to review the current state of the art.

  8. Delivery of Optical Contrast Agents using Triton-X100, Part 1: Reversible permeabilization of live cells for intracellular labeling

    OpenAIRE

    van de Ven, Anne L; Adler-Storthz, Karen; Richards-Kortum, Rebecca

    2009-01-01

    Effective delivery of optical contrast agents into live cells remains a significant challenge. We sought to determine whether Triton-X100, a detergent commonly used for membrane isolation and protein purification, could be used to effectively and reversibly permeabilize live cells for delivery of targeted optical contrast agents. Although Triton-X100 is widely recognized as a good cell permeabilization agent, no systematic study has evaluated the efficiency, reproducibility, and reversibility...

  9. MR angiography of the carotid arteries and intracranial circulation: advantage of a high relaxivity contrast agent

    International Nuclear Information System (INIS)

    Anzalone, N.; Scotti, R.; Iadanza, A.

    2006-01-01

    Several studies have shown the usefulness of contrast-enhanced MR angiography (CE-MRA) for imaging the supraortic vessels, and, as a consequence, it has rapidly become a routine imaging modality. The main advantage over unenhanced techniques is the possibility to acquire larger volumes, allowing demonstration of the carotid artery from its origin to the intracranial portion. Most published studies on CE-MRA of the carotid arteries have been performed with standard Gd-based chelates whose T1 relaxivity values are similar. Recently new gadolinium chelates such as gadobenate dimeglumine (Gd-BOP-TA, MultiHance; Bracco Imaging, Milan, Italy) have been developed which have markedly higher intravascular T1 relaxivity values. When administered at an equivalent dose to that of a standard agent, these newer contrast agents produce significantly greater intravascular signal enhancement. The availability of an appropriate high-relaxivity contrast agent might also help to overcome some of the intrinsic technical problems (e. g. those related to flow) that affect time-of-flight (TOF) and phase contrast (PC) MR angiography of the intracranial vasculature. To avoid the problem of superimposition of veins, ultrafast gradient echo MRA techniques with very short TR and TE have been developed. Although the precise sequence parameters vary between manufacturers, they are basically similar. The choice between performing a time-resolved or high spatial resolution CE-MRA examination depends upon the precise clinical application. The most common applications include the study of cerebral aneurysms, arteriovenous malformations, dural arteriovenous fistulas and dural venous diseases

  10. Risk Stratification of iodine-induced thyrotoxicosis before contrast agent application

    International Nuclear Information System (INIS)

    Fricke, E.

    2004-01-01

    Today, examinations using iodine containing contrast media are rather frequent. Even though in modern contrast agents the content of free iodine is low, in vivo deiodination results in a non physiologic high iodine load of the thyroid gland. Whilst in normal thyroid tissue iodine metabolism and hormone production are self-regulating in spite of the variable iodine load, those mechanisms are disturbed in autonomous thyroid tissue. Clinical studies displayed low risk of iodine induced thyrotoxicosis after application of contrast agent. Nonetheless the clinician has to assess the risk of thyrotoxicosis for each individual patient and he has to decide how to cope with this risk. Thyroid scintigraphy using Tc-99m-pertechnetate with quantitative measurement of the thyroidal uptake (TcTU) has been shown to be a useful tool in this question, especially when performed under suppression of the non-autonomous tissue (TcTUs). In particular patients with pre-existing suppression of the TSH secretion should be selected for this investigation. Also at risk are elderly persons and those with diffuse or nodular goitres. In spite of the high frequency of contrast agent applications, data on scintigraphy for risk evaluation of thyrotoxicosis and on efficacy of prophylactic medication are scarce. Based on own results and on a review of literature, the risk of thyrotoxicosis seems to be negligible in patients with a TcTUs of less than 1% even in case of preexistent latent hyperthyroidism. If a suppressed TSH level is known and TcTUs is higher than 1%, prophylactic medication should be given. There is evidence for a combination therapy inhibiting both iodine uptake and metabolism, i.e. with perchlorate and thiamazole, being more efficient than monotherapy, particularly in patients with high risk of thyrotoxicosis. (orig.)

  11. Risk Stratification of iodine-induced thyrotoxicosis before contrast agent application; Prognosebeurteilung bei geplanter Kontrastmittelexposition

    Energy Technology Data Exchange (ETDEWEB)

    Fricke, E. [Inst. fuer Molekulare Biophysik, Radiochemie und Nuklearmedizin, Herz- und Diabeteszentrum, Nordrheinwestfalen, Bad Oeynhausen (Germany)

    2004-06-01

    Today, examinations using iodine containing contrast media are rather frequent. Even though in modern contrast agents the content of free iodine is low, in vivo deiodination results in a non physiologic high iodine load of the thyroid gland. Whilst in normal thyroid tissue iodine metabolism and hormone production are self-regulating in spite of the variable iodine load, those mechanisms are disturbed in autonomous thyroid tissue. Clinical studies displayed low risk of iodine induced thyrotoxicosis after application of contrast agent. Nonetheless the clinician has to assess the risk of thyrotoxicosis for each individual patient and he has to decide how to cope with this risk. Thyroid scintigraphy using Tc-99m-pertechnetate with quantitative measurement of the thyroidal uptake (TcTU) has been shown to be a useful tool in this question, especially when performed under suppression of the non-autonomous tissue (TcTUs). In particular patients with pre-existing suppression of the TSH secretion should be selected for this investigation. Also at risk are elderly persons and those with diffuse or nodular goitres. In spite of the high frequency of contrast agent applications, data on scintigraphy for risk evaluation of thyrotoxicosis and on efficacy of prophylactic medication are scarce. Based on own results and on a review of literature, the risk of thyrotoxicosis seems to be negligible in patients with a TcTUs of less than 1% even in case of preexistent latent hyperthyroidism. If a suppressed TSH level is known and TcTUs is higher than 1%, prophylactic medication should be given. There is evidence for a combination therapy inhibiting both iodine uptake and metabolism, i.e. with perchlorate and thiamazole, being more efficient than monotherapy, particularly in patients with high risk of thyrotoxicosis. (orig.)

  12. Characterization of hepatic lesions (≤30 mm) with liver-specific contrast agents: A comparison between ultrasound and magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, Masanori, E-mail: machat1215@yahoo.co.jp [Department of Medicine and Clinical Oncology, Chiba University Graduate School of Medicine, 1-8-1 Inohana, Chuo-ku, Chiba 260-8670 (Japan); Maruyama, Hitoshi, E-mail: maru-cib@umin.ac.jp [Department of Medicine and Clinical Oncology, Chiba University Graduate School of Medicine, 1-8-1 Inohana, Chuo-ku, Chiba 260-8670 (Japan); Shimada, Taro, E-mail: bobtaro51@yahoo.co.jp [Department of Medicine and Clinical Oncology, Chiba University Graduate School of Medicine, 1-8-1 Inohana, Chuo-ku, Chiba 260-8670 (Japan); Kamezaki, Hidehiro, E-mail: ugn29814@yahoo.co.jp [Department of Medicine and Clinical Oncology, Chiba University Graduate School of Medicine, 1-8-1 Inohana, Chuo-ku, Chiba 260-8670 (Japan); Sekimoto, Tadashi, E-mail: tad_sekimoto@yahoo.co.jp [Department of Medicine and Clinical Oncology, Chiba University Graduate School of Medicine, 1-8-1 Inohana, Chuo-ku, Chiba 260-8670 (Japan); Kanai, Fumihiko, E-mail: kanaif@faculty.chiba-u.jp [Department of Medicine and Clinical Oncology, Chiba University Graduate School of Medicine, 1-8-1 Inohana, Chuo-ku, Chiba 260-8670 (Japan); Yokosuka, Osamu, E-mail: yokosukao@faculty.chiba-u.jp [Department of Medicine and Clinical Oncology, Chiba University Graduate School of Medicine, 1-8-1 Inohana, Chuo-ku, Chiba 260-8670 (Japan)

    2013-01-15

    Purpose: Imaging-based differentiation of hepatic lesions (≤30 mm) between well-differentiated hepatocellular carcinomas (w-HCC) and regenerative nodules (RN) presents difficulties. The aim was to compare the diagnostic abilities to differentiate w-HCC from RN using contrast-enhanced ultrasound and magnetic resonance imaging (MRI) both with liver-specific contrast agents. Materials and methods: This prospective study included 67 pathologically proven hepatic lesions (17.5 ± 5.4 mm, 54 w-HCCs, 13 RNs) in 56 patients with chronic hepatitis/cirrhosis (male 40, female 16; 29–79y). Hepatic-arterial/liver-specific phase enhancements were assessed quantitatively by ultrasound with perflubutane microbubble agent and MRI with gadolinium-ethoxybenzyl-diethylenetriamine with respect to the histological findings. Results: Sensitivity, specificity and accuracy of hepatic-arterial phase hyper-enhancement for w-HCC were 59.3%, 100% and 67.2% by ultrasound and 46.3%, 100% and 56.7% by MRI without significant difference. Meanwhile, those of liver-specific-phase hypo-enhancement for w-HCC were 44.4%, 100% and 55.2% by ultrasound and 87.0% (p < 0.0001), 46.2% (p = 0.0052) and 79.1% (p = 0.0032) by MRI. Diagnostic accuracies for w-HCC by area under the receiver operating characteristic curves were higher in the hepatic-arterial phase in ultrasound (0.8316) than MRI (0.6659, p = 0.0101) and similar in the liver-specific phase in ultrasound (0.7225) and MRI (0.7347, p = 0.8814). Conclusions: Hypervascularity is a significant feature which distinguishes w-HCC from RN, and ultrasound exerts a beneficial impact better than MRI for such characterization. However, both imaging have comparable abilities in the characterization of non-hypervascular lesions, compensating mutually for the poor sensitivity of ultrasound and the poor specificity of MRI in the liver-specific phase.

  13. Enhanced conjugation stability and blood circulation time of macromolecular gadolinium-DTPA contrast agent

    Energy Technology Data Exchange (ETDEWEB)

    Jenjob, Ratchapol [Department of New Drug Development, School of Medicine, Inha University, 2F A-dong, Jeongseok Bldg., Sinheung-dong 3-ga, Jung-gu, Incheon 400-712 (Korea, Republic of); Kun, Na [Department of Biotechnology, The Catholic University of Korea, 43 Jibong-ro, Wonmi-gu, Bucheon-si, Gyeonggi-do 420-743 (Korea, Republic of); Ghee, Jung Yeon [Utah-Inha DDS and Advanced Therapeutics, B-403 Meet-You-All Tower, SongdoTechnopark, 7–50, Songdo-dong, Yeonsu-gu, Incheon 406-840 (Korea, Republic of); Shen, Zheyu; Wu, Xiaoxia [Division of Functional Materials and Nano-Devices, Ningbo Institute of Materials Technology & Engineering (NIMTE), Chinese Academy of Sciences, 519 Zhuangshi Street, Zhenhai District, Ningbo, Zhejiang 315201 (China); Cho, Steve K., E-mail: scho@gist.ac.kr [Division of Liberal Arts and Science, GIST College, Gwangju Institute of Science and Technology, Gwangju 500-712 (Korea, Republic of); Lee, Don Haeng [Utah-Inha DDS and Advanced Therapeutics, B-403 Meet-You-All Tower, SongdoTechnopark, 7–50, Songdo-dong, Yeonsu-gu, Incheon 406-840 (Korea, Republic of); Department of Internal Medicine, School of Medicine, Inha University Hospital, Incheon 420-751 (Korea, Republic of); Yang, Su-Geun, E-mail: Sugeun.Yang@Inha.ac.kr [Department of New Drug Development, School of Medicine, Inha University, 2F A-dong, Jeongseok Bldg., Sinheung-dong 3-ga, Jung-gu, Incheon 400-712 (Korea, Republic of)

    2016-04-01

    In this study, we prepared macromolecular MR T1 contrast agent: pullulan-conjugated Gd diethylene triamine pentaacetate (Gd-DTPA-Pullulan) and estimated residual free Gd{sup 3+}, chelation stability in competition with metal ions, plasma and tissue pharmacokinetics, and abdominal MR contrast on rats. Residual free Gd{sup 3+} in Gd-DTPA-Pullulan was measured using colorimetric spectroscopy. The transmetalation of Gd{sup 3+} incubated with Ca{sup 2+} was performed by using a dialysis membrane (MWCO 100–500 Da) and investigated by ICP-OES. The plasma concentration profiles of Gd-DTPA-Pullulan were estimated after intravenous injection at a dose 0.1 mmol/kg of Gd. The coronal-plane abdominal images of normal rats were observed by MR imaging. The content of free Gd{sup 3+}, the toxic residual form, was less than 0.01%. Chelation stability of Gd-DTPA-Pullulan was estimated, and only 0.2% and 0.00045% of Gd{sup 3+} were released from Gd-DTPA-Pullulan after 2 h incubation with Ca{sup 2+} and Fe{sup 2+}, respectively. Gd-DTPA-Pullulan displayed the extended plasma half-life (t{sub 1/2,α} = 0.43 h, t{sub 1/2,β} = 2.32 h), much longer than 0.11 h and 0.79 h of Gd-EOB-DTPA. Abdominal MR imaging showed Gd-DTPA-Pullulan maintained initial MR contrast for 30 min. The extended plasma half-life of Gd-DTPA-Pullulan probably allows the prolonged MR acquisition time in clinic with enhanced MR contrast. - Highlights: • Macromolecule (pullulan) conjugated Gd contrast agent (Gd-DTPA-Pullulan) showed the extended plasma half-life (t{sub 1/2,α} = 0.43 h, t{sub 1/2,β} = 2.32 h) in comparison with Gd-EOB-DTPA • Gd-DTPA-pullulan T1 contrast agent exhibited strong chelation stability against Gd. • The extended blood circulation attributed the enhanced and prolonged MR contrast on abdominal region of rats. • The extended blood circulation may provide prolonged MR acquisition time window in clinics.

  14. Facile Synthesis of Gd-Functionalized Gold Nanoclusters as Potential MRI/CT Contrast Agents

    Directory of Open Access Journals (Sweden)

    Wenjun Le

    2016-04-01

    Full Text Available Multi-modal imaging plays a key role in the earlier detection of disease. In this work, a facile bioinspired method was developed to synthesize Gd-functionalized gold nanoclusters (Gd-Au NCs. The Gd-Au NCs exhibit a uniform size, with an average size of 5.6 nm in dynamic light scattering (DLS, which is a bit bigger than gold clusters (3.74 nm, DLS, while the fluorescent properties of Gd-Au NCs are almost the same as that of Au NCs. Moreover, the Gd-Au NCs exhibit a high longitudinal relaxivity value (r1 of 22.111 s−1 per mM of Gd in phosphate-buffered saline (PBS, which is six times higher than that of commercial Magnevist (A complex of gadolinium with a chelating agent, diethylenetriamine penta-acetic acid, Gd-DTPA, r1 = 3.56 mM−1·s−1. Besides, as evaluated by nano single photon emission computed tomography (SPECT and computed tomography (CT the Gd-Au NCs have a potential application as CT contrast agents because of the Au element. Finally, the Gd-Au NCs show little cytotoxicity, even when the Au concentration is up to 250 μM. Thus, the Gd-Au NCs can act as multi-modal imaging contrast agents.

  15. The feasibility of a targeted ultrasound contrast agent carrying genes and cell-penetrating peptides to hypoxic HUVEC

    International Nuclear Information System (INIS)

    Tian Ju; Wang Zhigang; Ren Jianli; Zhang Qingfeng; Liu Li

    2012-01-01

    Objective: To prepare an anti-P-selectin targeted ultrasound contrast agent carrying genes and cell-penetrating peptides (CPP) and to investigate its feasibility of delivery to hypoxic human umbilical vein endothelial cells (HUVEC). Methods: Anti-P-selectin targeted ultrasound contrast agent carrying a green fluorescent protein gene (pEGFP-N1) and CPP was prepared by mechanical vibration and carbodiimide techniques. The appearance, distribution, concentration and diameter of the ultrasound contrast agent were measured. The gene and CPP distribution on the agent was investigated using confocal laser scanning microscopy (CLSM). The efficiency of the ultrasound contrast agent to carry the gene and CPP was investigated by fluorospectrophotometry. HUVEC were cultured in vitro and hypoxic HUVEC were prepared using hydrogen peroxide (H 2 O 2 ). Hypoxic HUVEC were randomly assigned targeted ultrasound contrast agents and non-targeted ultrasound contrast agents for transfection. The transfection effect of green fluorescent protein in the two groups was observed using fluorescence microscopy and flow cytometry. T-test and linear correlation analysis were used for statistical analysis. Results: The average diameter of anti-P-selectin targeted ultrasound contrast agents carrying gene and CPP was (2.15 ±0.36) μm and the concentration was (1.58 ± 0.23) × 10 7 /ml.The results of CLSM showed that gene and CPP were distributed on the shell of the agent. The gene encapsulation efficiency was 28% (y=0.932x-0.09, r=0.993, P<0.05), and the CPP encapsulation efficiency was 25% (y=5.875x-0.81, r=0.987, P<0.05). EGFP expression was observed using fluorescence microscopy in targeted ultrasound contrast agents and non-targeted ultrasound contrast agents. The average transfection efficiencies of targeted ultrasound contrast agents and non-targeted ultrasound contrast agents were (18.74 ± 0.47) % and (15.34 ± 0.22) % after 24 h (t=10.923, P<0.001). Conclusions: The in vitro studies

  16. Ferric ammonium citrate as a positive bowel contrast agent for MR imaging of the upper abdomen

    Energy Technology Data Exchange (ETDEWEB)

    Kivelitz, D.; Taupitz, M.; Hamm, B. [Universitaetsklinikum Charite, Berlin (Germany). Inst. fuer Radiologie; Gehl, H.B. [Medizinische Univ. Luebeck (Germany). Inst. fuer Radiologie; Heuck, A. [Muenchen Univ. (Germany). Radiologische Klinik; Krahe, T. [Koeln Univ. (Germany). Inst. fuer Radiologische Diagnostik; Lodemann, K.P. [Bracco-Byk Gulden GmbH, Konstanz (Germany)

    1999-07-01

    Purpose: To evaluate the safety and diagnostic efficacy of two different doses of ferric ammonium citrate as a paramagnetic oral contrast agent for MR imaging of the upper abdomen. Material and methods: Ninety-nine adult patients referred for MR imaging for a known or suspected upper abdominal pathology were included in this randomized multicenter double-blind clinical trial. Imaging was performed with spin-echo (T1- and T2-weighted) and gradient-echo (T1-weighted) techniques before and after administration of either 1200 mg or 2400 mg of ferric ammonium citrate dissolved in 600 ml of water. Safety analysis included monitoring of vital signs, assessment of adverse events, and laboratory testing. Efficacy with regard to organ distension, contrast distribution, bowel enhancement and delineation of adjacent structures was graded qualitatively. Results: No serious adverse events were reported for either of the two concentrations. A total of 31 minor side effects were noted, of which significantly more occurred in the higher dose group (p<0.01). The diagnostic confidence in defining or excluding disease was graded as better after contrast administration for 48% of all images. Marked or moderate enhancement of the upper gastrointestinal tract was achieved at both doses in 69.5% of cases with no evident difference between the two doses. The higher dose tended to show better results in terms of the contrast assessment parameters. Conclusion: Ferric ammonium citrate is a safe and effective oral contrast agent for MR imaging of the upper abdomen at two different dose levels. The higher dose showed a tendency toward better imaging results while the lower dose caused significantly fewer side effects. Therefore, the 1200 mg dose can be recommended in view of the risk-to-benefit ratio. (orig.)

  17. Inorganic nanocrystals as contrast agents in MRI:synthesis, coating and introducing multifunctionality

    Science.gov (United States)

    Sanchez-Gaytan, Brenda L.; Mieszawska, Aneta J.; Fayad, Zahi A.

    2013-01-01

    Inorganic nanocrystals have myriad applications in medicine, which includes their use as drug or gene delivery complexes, therapeutic hyperthermia agents, in diagnostic systems and as contrast agents in a wide range of medical imaging techniques. For MRI, nanocrystals can produce contrast themselves, of which iron oxides have been most extensively explored, or be given a coating that generates MR contrast, for example gold nanoparticles coated with gadolinium chelates. These MR-active nanocrystals can be used in imaging of the vasculature, liver and other organs, as well as molecular imaging, cell tracking and theranostics. Due to these exciting applications, synthesizing and rendering these nanocrystals water-soluble and biocompatible is therefore highly desirable. We will discuss aqueous phase and organic phase methods for synthesizing inorganic nanocrystals such as gold, iron oxides and quantum dots. The pros and cons of the various methods will be highlighted. We explore various methods for making nanocrystals biocompatible, i.e. directly synthesizing nanocrystals coated with biocompatible coatings, ligand substitution, amphiphile coating and embedding in carrier matrices that can be made biocompatible. Various examples will be highlighted and their applications explained. These examples signify that synthesizing biocompatible nanocrystals with controlled properties has been achieved by numerous research groups and can be applied for a wide range of applications. Therefore we expect to see reports of preclinical applications of ever more complex MRI-active nanoparticles and their wider exploitation, as well as in novel clinical settings. PMID:23303729

  18. Silicon nanoparticles as contrast agents in the methods of optical biomedical diagnostics

    Science.gov (United States)

    Zabotnov, S. V.; Kashaev, F. V.; Shuleiko, D. V.; Gongalsky, M. B.; Golovan, L. A.; Kashkarov, P. K.; Loginova, D. A.; Agrba, P. D.; Sergeeva, E. A.; Kirillin, M. Yu

    2017-07-01

    The efficiency of light scattering by nanoparticles formed using the method of picosecond laser ablation of silicon in water and by nanoparticles of mechanically grinded mesoporous silicon is compared. The ensembles of particles of both types possess the scattering coefficients sufficient to use them as contrast agents in optical coherence tomography (OCT), particularly in the range of wavelengths 700-1000 nm, where the absorption of both silicon and most biological and mimicking tissues is small. According to the Mie theory the main contribution to the scattering in this case is made by the particles having a relatively large size (150-300 nm). In the experiments on visualising the agar phantom surface by means of OCT, the contrast of the medium boundary, provided by nanoparticles amounted to 14 dB and 30 dB for the ablated particles and the porous silicon powder, respectively. The numerical simulation of OCT images of skin in the presence of nanoparticles, confirmed the efficiency of using them as a contrast agent.

  19. Effects of gadolinium-based MRI contrast agents on liver tissue.

    Science.gov (United States)

    Mercantepe, Tolga; Tümkaya, Levent; Çeliker, Fatma Beyazal; Topal Suzan, Zehra; Çinar, Seda; Akyildiz, Kerimali; Mercantepe, Filiz; Yilmaz, Adnan

    2018-04-01

    MRI with contrast is often used clinically. However, recent studies have reported a high accumulation of gadolinium-based contrast agents (GBCAs) in kidney, liver, and spleen tissues in several mouse models. To compare the effects on liver tissue of gadolinium-based MRI contrast agents in the light of biochemical and histopathological evaluation. Institutional Review Board (IRB)-approved controlled longitudinal study. In all, 32 male Sprague-Dawley rats were divided into a healthy control group subjected to no procedure (Group 1), a sham group (Group 2), a gadodiamide group (Group 3), and a gadoteric acid group (Group 4). Not applicable. Liver tissues removed at the end of the fifth week and evaluated pathologically (scored Knodell's histological activity index [HAI] method by two histopathologists) immunohistochemical (caspase-3 and biochemical tests (AST, ALT, TAS, TOS, and OSI method by Erel et al) were obtained. Differences between groups were analyzed using the nonparametric Kruskal-Wallis test followed by the Tamhane test, and one-way analysis of variance (ANOVA) followed by Turkey's HSD test. An increase was observed in histological activity scores in sections from rats administered gadodiamide and gadoteric acid, and in caspase-3, AST and ALT values (P total antioxidant and antioxidant capacity. 1 Technical Efficacy: Stage 4 J. Magn. Reson. Imaging 2018. © 2018 International Society for Magnetic Resonance in Medicine.

  20. Magnetic resonance imaging using paramagnetic contrast agents in the clinical evaluation of myocardial infarction. Chapter 15

    International Nuclear Information System (INIS)

    Dijkman, P.R.M. van; Wall, E.E. van der

    1992-01-01

    MRI is noninvasive and specific method for production of high resolution tomographic images in blocks of 3D information. Apart from scintigraphic techniques and computed tomography for evaluation of myocardial ischemia and infarcts, MRI has emerged as a new diagnostic technique to study the extent of anatomical and functional abnormalities in patients with coronary artery disease. Conventional noncontrast MRI can identify acute-infarcted myocardial areas, although the difficulty in identifying myocardial ischemia and infarct with noncontrast MRI suggests a potential role for contrast enhanced MRI. Use of the paramagnetic contrast agent gadolinium diethylene triamine pentaacetic acid (Gd-DTPA) improves depiction of infarcted myocardium on T1-weighted spin -echo MR images that are obtained soon after acute myocardial infarction. This is of particular interest for the estimation of myocardial infarct size. Furthermore, ultrafast subsecond imaging, in combination with Gd-DTPA, offers the potential to analyze cardiac first pass and myocardial perfusion. The development of nontoxic paramagnetic contrast agents which are selectively taken up by viable myocardium would be helpful in assessing the presence of ischemic/infarcted myocardium salvage by MRI following reperfusion. (author). 58 refs., 6 figs

  1. Self-Assembled Nanomicelles as MRI Blood-Pool Contrast Agent.

    Science.gov (United States)

    Babič, Andrej; Vorobiev, Vassily; Xayaphoummine, Céline; Lapicorey, Gaëlle; Chauvin, Anne-Sophie; Helm, Lothar; Allémann, Eric

    2018-01-26

    Gadolinium-loaded nanomicelles show promise as future magnetic resonance imaging (MRI) contrast agents (CAs). Their increased size and high gadolinium (Gd) loading gives them an edge in proton relaxivity over smaller molecular Gd-complexes. Their size and stealth properties are fundamental for their long blood residence time, opening the possibility for use as blood-pool contrast agents. Using l-tyrosine as a three-functional scaffold we synthesized a nanostructure building block 8. The double C18 aliphatic chain on one side, Gd-1,4,7,10-tetraazacyclododecane-1-4-7-triacetic acid (Gd-DO3A) with access to bulk water in the center and 2 kDa PEG on the hydrophilic side gave the amphiphilic properties required for the core-shell nanomicellar architecture. The self-assembly into Gd-loaded monodispersed 10-20 nm nanomicelles occurred spontaneously in water. These nanomicelles (Tyr-MRI) display very high relaxivity at 29 mm -1  s -1 at low field strength and low cytotoxicity. Good contrast enhancement of the blood vessels and the heart together with prolonged circulation time in vivo, makes Tyr-MRI an excellent candidate for a new supramolecular blood-pool MRI CA. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Saline as the Sole Contrast Agent for Successful MRI-guided Epidural Injections

    International Nuclear Information System (INIS)

    Deli, Martin; Fritz, Jan; Mateiescu, Serban; Busch, Martin; Carrino, John A.; Becker, Jan; Garmer, Marietta; Grönemeyer, Dietrich

    2013-01-01

    Purpose. To assess the performance of sterile saline solution as the sole contrast agent for percutaneous magnetic resonance imaging (MRI)-guided epidural injections at 1.5 T. Methods. A retrospective analysis of two different techniques of MRI-guided epidural injections was performed with either gadolinium-enhanced saline solution or sterile saline solution for documentation of the epidural location of the needle tip. T1-weighted spoiled gradient echo (FLASH) images or T2-weighted single-shot turbo spin echo (HASTE) images visualized the test injectants. Methods were compared by technical success rate, image quality, table time, and rate of complications. Results. 105 MRI-guided epidural injections (12 of 105 with gadolinium-enhanced saline solution and 93 of 105 with sterile saline solution) were performed successfully and without complications. Visualization of sterile saline solution and gadolinium-enhanced saline solution was sufficient, good, or excellent in all 105 interventions. For either test injectant, quantitative image analysis demonstrated comparable high contrast-to-noise ratios of test injectants to adjacent body substances with reliable statistical significance levels (p < 0.001). The mean table time was 22 ± 9 min in the gadolinium-enhanced saline solution group and 22 ± 8 min in the saline solution group (p = 0.75). Conclusion. Sterile saline is suitable as the sole contrast agent for successful and safe percutaneous MRI-guided epidural drug delivery at 1.5 T.

  3. Large abnormal peak on capillary zone electrophoresis due to contrast agent.

    Science.gov (United States)

    Wheeler, Rachel D; Zhang, Liqun; Sheldon, Joanna

    2017-01-01

    Background Some iodinated radio-contrast media absorb ultraviolet light and can therefore be detected by capillary zone electrophoresis. If seen, these peaks are typically small with 'quantifications' of below 5 g/L. Here, we describe the detection of a large peak on capillary zone electrophoresis that was due to the radio-contrast agent, Omnipaque™. Methods Serum from a patient was analysed by capillary zone electrophoresis, and the IgG, IgA, IgM and total protein concentrations were measured. The serum sample was further analysed by gel electrophoresis and immunofixation. Results Capillary zone electrophoresis results for the serum sample showed a large peak with a concentration high enough to warrant urgent investigation. However, careful interpretation alongside the serum immunoglobulin concentrations and total protein concentration showed that the abnormal peak was a pseudoparaprotein rather than a monoclonal immunoglobulin. This was confirmed by analysis with gel electrophoresis and also serum immunofixation. The patient had had a CT angiogram with the radio-contrast agent Omnipaque™; addition of Omnipaque™ to a normal serum sample gave a peak with comparable mobility to the pseudoparaprotein in the patient's serum. Conclusions Pseudoparaproteins can appear as a large band on capillary zone electrophoresis. This case highlights the importance of a laboratory process that detects significant electrophoretic abnormalities promptly and interprets them in the context of the immunoglobulin concentrations. This should avoid incorrect reporting of pseudoparaproteins which could result in the patient having unnecessary investigations.

  4. Manganese and Gd-DTPA stearyl liposomes as reticuloendothelial-system-specific MR imaging contrast agents

    International Nuclear Information System (INIS)

    Wuthrich, R.; Schwendener, R.; Duewell, S.; VonSchulthess, G.K.; Fuchs, W.A.

    1988-01-01

    Liposomes can be used to target metal ions as MR contrast agents to liver and spleen. It was the aim of this work to examine unilamellar liposomes containing manganese and gadolinium ions with respect to their targetting ability, contrast enhancement, and in vivo kinetics in rats and dogs. Unilamellar liposomes containing DTPA stearate were complexed with Mn/sup 2+/ and Gd/sup 3+/ resulting in vesicles of 30-40 nm. Injected into rats, approximately 35% of manganese liposomes were present in the liver after 30-60 minutes, and after 24 hours more than 80% had been eliminated. The pharmacokinetics of gadolinium were more protracted. In MR imaging, a reduction in the T1 of the liver parenchyma from 450 to 170 and 280 msec was observed for manganese and gadolinium liposomes (0.03 mmol/kg body weight), respectively, with the liver appearing as bright as fat. Manganese (and Gd-DTPA) stearyl liposomes are potential organ-selective contrast agents for liver and spleen and are eliminated through a hepatobiliary route

  5. Performance characteristics of magnetic resonance imaging without contrast agents or sedation in pediatric appendicitis.

    Science.gov (United States)

    Didier, Ryne A; Hopkins, Katharine L; Coakley, Fergus V; Krishnaswami, Sanjay; Spiro, David M; Foster, Bryan R

    2017-09-01

    Magnetic resonance imaging (MRI) has emerged as a promising modality for evaluating pediatric appendicitis. However optimal imaging protocols, including roles of contrast agents and sedation, have not been established and diagnostic criteria have not been fully evaluated. To investigate performance characteristics of rapid MRI without contrast agents or sedation in the diagnosis of pediatric appendicitis. We included patients ages 4-18 years with suspicion of appendicitis who underwent rapid MRI between October 2013 and March 2015 without contrast agent or sedation. After two-radiologist review, we determined performance characteristics of individual diagnostic criteria and aggregate diagnostic criteria by comparing MRI results to clinical outcomes. We used receiver operating characteristic (ROC) curves to determine cut-points for appendiceal diameter and wall thickness for optimization of predictive power, and we calculated area under the curve (AUC) as a measure of test accuracy. Ninety-eight MRI examinations were performed in 97 subjects. Overall, MRI had a 94% sensitivity, 95% specificity, 91% positive predictive value and 97% negative predictive value. Optimal cut-points for appendiceal diameter and wall thickness were ≥7 mm and ≥2 mm, respectively. Independently, those cut-points produced sensitivities of 91% and 84% and specificities of 84% and 43%. Presence of intraluminal fluid (30/33) or localized periappendiceal fluid (32/33) showed a significant association with acute appendicitis (Pappendicitis when multiple diagnostic criteria are considered in aggregate. Individual diagnostic criteria including optimized cut-points of ≥7 mm for diameter and ≥2 mm for wall thickness demonstrate high sensitivities but relatively low specificities. Nonvisualization of the appendix favors a negative diagnosis.

  6. Gadolinium-conjugated PLA-PEG nanoparticles as liver targeted molecular MRI contrast agent.

    Science.gov (United States)

    Chen, Zhijin; Yu, Dexin; Liu, Chunxi; Yang, Xiaoyan; Zhang, Na; Ma, Chunhong; Song, Jibin; Lu, Zaijun

    2011-09-01

    A nanoparticle magnetic resonance imaging (MRI) contrast agent targeted to liver was developed by conjugation of gadolinium (Gd) chelate groups onto the biocompatible poly(l-lactide)-block-poly (ethylene glycol) (PLA-PEG) nanoparticles. PLA-PEG conjugated with diethylenetriaminopentaacetic acid (DTPA) was used to formulate PLA-PEG-DTPA nanoparticles by solvent diffusion method, and then Gd was loaded onto the nanoparticles by chelated with the unfolding DTPA on the surface of the PLA-PEG-DTPA nanoparticles. The mean size of the nanoparticles was 265.9 ± 6.7 nm. The relaxivity of the Gd-labeled nanoparticles was measured, and the distribution in vivo was evaluated in rats. Compared with conventional contrast agent (Magnevist), the Gd-labeled PLA-PEG nanoparticles showed significant enhancement both on liver targeting ability and imaging signal intensity. The T(1) and T(2) relaxivities per [Gd] of the Gd-labeled nanoparticles was 18.865 mM(-1) s(-1) and 24.863 mM(-1) s(-1) at 3 T, respectively. In addition, the signal intensity in vivo was stronger comparing with the Gd-DTPA and the T(1) weight time was lasting for 4.5 h. The liver targeting efficiency of the Gd-labeled PLA-PEG nanoparticles in rats was 14.57 comparing with Magnevist injection. Therefore, the Gd-labeled nanoparticles showed the potential as targeting molecular MRI contrast agent for further clinical utilization.

  7. Contrast ultrasound targeted treatment of gliomas in mice via drug-bearing nanoparticle delivery and microvascular ablation.

    Science.gov (United States)

    Burke, Caitlin W; Price, Richard J

    2010-12-15

    We are developing minimally-invasive contrast agent microbubble based therapeutic approaches in which the permeabilization and/or ablation of the microvasculature are controlled by varying ultrasound pulsing parameters. Specifically, we are testing whether such approaches may be used to treat malignant brain tumors through drug delivery and microvascular ablation. Preliminary studies have been performed to determine whether targeted drug-bearing nanoparticle delivery can be facilitated by the ultrasound mediated destruction of "composite" delivery agents comprised of 100nm poly(lactide-co-glycolide) (PLAGA) nanoparticles that are adhered to albumin shelled microbubbles. We denote these agents as microbubble-nanoparticle composite agents (MNCAs). When targeted to subcutaneous C6 gliomas with ultrasound, we observed an immediate 4.6-fold increase in nanoparticle delivery in MNCA treated tumors over tumors treated with microbubbles co-administered with nanoparticles and a 8.5 fold increase over non-treated tumors. Furthermore, in many cancer applications, we believe it may be desirable to perform targeted drug delivery in conjunction with ablation of the tumor microcirculation, which will lead to tumor hypoxia and apoptosis. To this end, we have tested the efficacy of non-theramal cavitation-induced microvascular ablation, showing that this approach elicits tumor perfusion reduction, apoptosis, significant growth inhibition, and necrosis. Taken together, these results indicate that our ultrasound-targeted approach has the potential to increase therapeutic efficiency by creating tumor necrosis through microvascular ablation and/or simultaneously enhancing the drug payload in gliomas.

  8. Gaucher disease in the liver on hepatocyte specific contrast agent enhanced MR imaging

    International Nuclear Information System (INIS)

    Ayyala, Rama S.; Teot, Lisa A.; Perez Rossello, Jeanette M.

    2017-01-01

    Gaucher disease is a hereditary lipid storage disorder that affects the enzyme beta glucocerebrosidase, causing accumulation of glucocerebroside in macrophages of the reticuloendothelial system. Accumulation can occur in the liver and spleen, manifesting as hepatosplenomegaly, as well as within the bone marrow. Hepatic involvement is usually diffuse but can occasionally manifest as focal liver lesions. We present a case of a 2-year-old boy with Gaucher disease and an infiltrating liver lesion detected on imaging, which was pathologically shown to be focal changes related to the disease. Imaging characteristics of this lesion using hepatocyte specific contrast agent enhanced MRI, which have not been previously discussed in the literature, are described. (orig.)

  9. Magnetosomes used as biogenic MRI contrast agent for molecular imaging of glioblastoma model

    International Nuclear Information System (INIS)

    Boucher, Marianne

    2016-01-01

    This work takes place in the context of molecular imaging, which aims at tailoring medical treatments and therapies to the individual context by revealing molecular or cellular phenomenon of medical interest in the less invasive manner. In particular, it can be achieved with MRI molecular imaging using engineered iron-oxide contrast agent.This PhD thesis focuses on the study of a new class of iron-oxide contrast agent for high field MRI. Indeed, magnetosomes are natural iron-oxide vesicles produced by magneto-tactic bacteria. These bacteria synthesized such magnetic vesicles and ordered them like a nano-compass in order to facilitate their navigation in sediments. This explains why magnetosomes are awarded with tremendous magnetic properties: around 50 nm, mono-crystalline, single magnetic domain and high saturation magnetization. Furthermore, a wide variety of bacterial strains exist in nature and size and shape of magnetosomes are highly stable within strain and can be very different between strains. Finally, magnetosomes are naturally coated with a bi-lipidic membrane whose content is genetically determined. Lately, researchers have unravelled magnetosomes membrane protein contents, opening the way to create functionalized magnetosomes thanks to fusion of the gene coding for a protein of interest with the gene coding for an abundant protein at magnetosomes membrane.A new alternative path using living organisms to tackle the production of engineered high efficiency molecular imaging probes have been investigated with magneto-tactic bacteria in this PhD. The production and engineering of magnetosomes have been carried out by our partner, the Laboratoire de Bio-energetique Cellulaire (LBC, CEA Cadarache), and will be presented and discussed. We then characterized magnetosomes as contrast agent for high field MRI. We showed they present very promising contrasting properties in vitro, and assessed this observation in vivo by establishing they can be used as efficient

  10. Iron oxide nanoparticles for use in contrast agents in magnetic resonance imaging

    International Nuclear Information System (INIS)

    Oliveira, Elisa M.N. de; Rocha, Maximiliano S. da; Caimi, Priscila de A.; Basso, Nara R. de S.; Zanini, Mara L.; Papaleo, Ricardo M.

    2015-01-01

    In this work were carried out synthesis of iron oxide nanoparticles coated with dextran, comparing the results of using different concentrations of dextran, iron salts, temperature and reaction time. The compounds were analyzed by DLS, XRD, TGA, TEM, FTIR, Zeta Potential and relaxivity. Nanoparticles with dispersion around 10-15 nm and average hydrodynamic diameters of 16-50 nm, with superparamagnetic behavior were obtained. The ratio of the relaxivities (r2/r1) in aqueous solutions was 5.30, close to value of the commercially available iron oxide contrast agents. (author)

  11. Chitosan-coated nickel-ferrite nanoparticles as contrast agents in magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Ahmad, Tanveer [Department of Physics, Kyungpook National University, Daegu 702-701 (Korea, Republic of); Department of Physics, Abdul Wali Khan University, Mardan (Pakistan); Bae, Hongsub; Iqbal, Yousaf [Department of Physics, Kyungpook National University, Daegu 702-701 (Korea, Republic of); Rhee, Ilsu, E-mail: ilrhee@knu.ac.kr [Department of Physics, Kyungpook National University, Daegu 702-701 (Korea, Republic of); Hong, Sungwook [Division of Science Education, Daegu University, Gyeongsan 712-714 (Korea, Republic of); Chang, Yongmin; Lee, Jaejun [Department of Diagnostic Radiology, College of Medicine, Kyungpook National University and Hospital, Daegu 700-721 (Korea, Republic of); Sohn, Derac [Department of Physics, Hannam University, Daejon (Korea, Republic of)

    2015-05-01

    We report evidence for the possible application of chitosan-coated nickel-ferrite (NiFe{sub 2}O{sub 4}) nanoparticles as both T{sub 1} and T{sub 2} contrast agents in magnetic resonance imaging (MRI). The coating of nickel-ferrite nanoparticles with chitosan was performed simultaneously with the synthesis of the nickel-ferrite nanoparticles by a chemical co-precipitation method. The coated nanoparticles were cylindrical in shape with an average length of 17 nm and an average width of 4.4 nm. The bonding of chitosan onto the ferrite nanoparticles was confirmed by Fourier transform infrared spectroscopy. The T{sub 1} and T{sub 2} relaxivities were 0.858±0.04 and 1.71±0.03 mM{sup −1} s{sup −1}, respectively. In animal experimentation, both a 25% signal enhancement in the T{sub 1}-weighted mage and a 71% signal loss in the T{sub 2}-weighted image were observed. This demonstrated that chitosan-coated nickel-ferrite nanoparticles are suitable as both T{sub 1} and T{sub 2} contrast agents in MRI. We note that the applicability of our nanoparticles as both T{sub 1} and T{sub 2} contrast agents is due to their cylindrical shape, which gives rise to both inner and outer sphere processes of nanoparticles. - Highlights: • Chitosan-coated nickel-ferrite (Ni-Fe{sub 2}O{sub 4}) nanoparticles were synthesized in an aqueous system by chemical co-precipitation. • The characterization of bare and chitosan-coated nanoparticles were performed using various analytical tools, such as TEM, FTIR, XRD, and VMS. • We evaluated the coated particles as potential T{sub 1} and T{sub 2} contrast agents for MRI by measuring T{sub 1} and T{sub 2} relaxation times as a function of iron concentration. • Both T{sub 1} and T{sub 2} effects were also observed in animal experimentation.

  12. Contrast Agents for Micro-Computed Tomography of Microdamage in Bone

    Science.gov (United States)

    2011-01-01

    However, cracks in the enamel were readily detected by micro-CT both with and without the use of a con- trast agent (Fig. 2(b)) due to the relatively low x...ray attenua- tion of the fluid space in the crack compared to the enamel . Therefore, the main limitation of the difficulty distinguishing BaSO4 from...Roeder, 2011). Moreover, cracks in whole human molars were also imaged by contrast-enhanced micro-CT (Appendix 5, Landrigan et al., 2010). KEY

  13. Gaucher disease in the liver on hepatocyte specific contrast agent enhanced MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Ayyala, Rama S. [Morgan Stanley Children' s Hospital, Department of Radiology, Columbia University Medical Center, New York, NY (United States); Teot, Lisa A. [Boston Children' s Hospital, Department of Pathology, Harvard Medical School, Boston, MA (United States); Perez Rossello, Jeanette M. [Boston Children' s Hospital, Department of Radiology, Harvard Medical School, Boston, MA (United States)

    2017-04-15

    Gaucher disease is a hereditary lipid storage disorder that affects the enzyme beta glucocerebrosidase, causing accumulation of glucocerebroside in macrophages of the reticuloendothelial system. Accumulation can occur in the liver and spleen, manifesting as hepatosplenomegaly, as well as within the bone marrow. Hepatic involvement is usually diffuse but can occasionally manifest as focal liver lesions. We present a case of a 2-year-old boy with Gaucher disease and an infiltrating liver lesion detected on imaging, which was pathologically shown to be focal changes related to the disease. Imaging characteristics of this lesion using hepatocyte specific contrast agent enhanced MRI, which have not been previously discussed in the literature, are described. (orig.)