WorldWideScience

Sample records for microbead immunosorbent assay

  1. Microbead agglutination based assays

    KAUST Repository

    Kodzius, Rimantas; Castro, David; Foulds, Ian G.; Parameswaran, Ash M.; Sumanpreet, K. Chhina

    2013-01-01

    We report a simple and rapid room temperature assay for point-of-care (POC) testing that is based on specific agglutination. Agglutination tests are based on aggregation of microbeads in the presence of a specific analyte thus enabling

  2. Microbead agglutination based assays

    KAUST Repository

    Kodzius, Rimantas

    2013-01-21

    We report a simple and rapid room temperature assay for point-of-care (POC) testing that is based on specific agglutination. Agglutination tests are based on aggregation of microbeads in the presence of a specific analyte thus enabling the macroscopic observation. Such tests are most often used to explore antibody-antigen reactions. Agglutination has been used for protein assays using a biotin/streptavidin system as well as a hybridization based assay. The agglutination systems are prone to selftermination of the linking analyte, prone to active site saturation and loss of agglomeration at high analyte concentrations. We investigated the molecular target/ligand interaction, explaining the common agglutination problems related to analyte self-termination, linkage of the analyte to the same bead instead of different microbeads. We classified the agglutination process into three kinds of assays: a two- component assay, a three-component assay and a stepped three- component assay. Although we compared these three kinds of assays for recognizing DNA and protein molecules, the assay can be used for virtually any molecule, including ions and metabolites. In total, the optimized assay permits detecting analytes with high sensitivity in a short time, 5 min, at room temperature. Such a system is appropriate for POC testing.

  3. Thermometric enzyme linked immunosorbent assay: TELISA.

    Science.gov (United States)

    Mattiasson, B; Borrebaeck, C; Sanfridson, B; Mosbach, K

    1977-08-11

    A new method, thermometric enzyme linked immunosorbent assay (TELISA), for the assay of endogenous and exogenous compounds in biological fluids is described. It is based on the previously described enzyme linked immunosorbent assay technique, ELISA, but utilizes enzymic heat formation which is measured in an enzyme thermistor unit. In the model system studied determination of human serum albumin down to a concentration of 10(-10) M (5 ng/ml) was achieved, with both normal and catalase labelled human serum albumin competing for the binding sites on the immunosorbent, which was rabbit antihuman serum albumin immobilized onto Sepharose CL-4B.

  4. Recombinant Helicobacter bilis Protein P167 for Mouse Serodiagnosis in a Multiplex Microbead Assay

    OpenAIRE

    Feng, Sunlian; Kendall, Lon V.; Hodzic, Emir; Wong, Scott; Lorenzana, Edward; Freet, Kimberly; Ku, Karin S.; Luciw, Paul A.; Barthold, Stephen W.; Khan, Imran H.

    2004-01-01

    Infection of mice with Helicobacter bilis is widespread in research and commercial mouse colonies. Therefore, sensitive, specific, and high-throughput assays are needed for rapid and accurate testing of mice in large numbers. This report describes a novel multiplex assay, based on fluorescent microbeads, for serodetection of H. bilis infection. The assay requires only a few microliters of serum to perform and is amenable to a high-throughput format. Individual microbead sets were conjugated t...

  5. Enzyme-Linked Immunosorbent Assay (ELISA).

    Science.gov (United States)

    Konstantinou, George N

    2017-01-01

    Food allergy is a public health concern especially after recognizing its constantly increased prevalence and severity. Despite careful reading of food ingredient statements, food allergic individuals may experience reactions caused by "hidden", "masked", or "contaminated" proteins that are known major allergens. Many techniques have been developed to detect even small traces of food allergens, for clinical or laboratory purposes. Enzyme-linked immunosorbent assay (ELISA) is one of the best validated and most routinely used immunoassay in allergy research, in allergy diagnosis in allergy-related quality control in various industries. Although as a technique it has been implemented for the last 45 years, the evolution in biochemistry allowed the development of ultrasensitive ELISA variations that are capable of measuring quantities in the scale of picograms, rendering ELISA attractive, robust, and very famous.

  6. A competitive enzyme linked immunosorbent assay for the ...

    African Journals Online (AJOL)

    A competitive enzyme linked immunosorbent assay for the determination of diminazene residues in animal tissues. ... After six washes with buffer, enzyme activity was determined by adding tetramethyl-benzidine and hydrogen peroxide as substrate. The assay detection limits for diminazene were 2.4 ng/g in muscle, 2.5 ...

  7. A study of the incubation of microbead agglutination assays in a microfluidic system

    KAUST Repository

    Castro, David

    2016-12-19

    This work reports on a quantitative study of the incubation of a microbead-based agglutination assay inside a microfluidic system. In this system, a droplet (1.25µL) consisting of a mixture of functionalized microbeads and analyte is flowed through a 0.51mm internal diameter silicone tube. Hydrodynamic forces alone produce a very efficient mixing of the beads within the droplet. We tested the agglutination at different speeds and show a robust response at the higher range of speeds (150 – 200µL/min), while also reaching a completion in the agglutination process. At these velocities, a length of 180cm is shown to be sufficient to confidently measure the agglutination assay, which takes between 2.5 – 3 minutes. This high throughput quantification method has the potential of accelerating the measurements of various types of biomarkers, which can greatly benefit the fields of biology and medicine.

  8. Enzyme-linked immunosorbent assays for Z-DNA.

    OpenAIRE

    Thomas, M J; Strobl, J S

    1988-01-01

    Dot blot and transblot enzyme-linked immunosorbent assays (e.l.i.s.a.) are described which provide sensitive non-radioactive methods for screening Z-DNA-specific antisera and for detecting Z-DNA in polydeoxyribonucleotides and supercoiled plasmids. In the alkaline phosphatase dot blot e.l.i.s.a., Z-DNA, Br-poly(dG-dC).poly(dG-dC), or B-DNA, poly(dG-dC).poly(dG-dC), poly(dA-dT).poly(dA-dT), Br-poly(dI-dC).poly(dI-dC), or salmon sperm DNA were spotted onto nitrocellulose discs and baked. The e....

  9. Desomorphine Screening Using Commercial Enzyme-Linked Immunosorbent Assays.

    Science.gov (United States)

    Winborn, Jessica; Kerrigan, Sarah

    2017-06-01

    Desomorphine ("Krokodil") is a semi-synthetic opioid that has drawn attention as a recreational drug, particularly in Russia, neighboring former Soviet Republics, Eastern and Central Europe. It has no accepted medicinal uses and is currently a schedule I drug in the United States. In clandestine environments, desomorphine is synthesized from codeine using red phosphorous, hydroiodic acid and gasoline. Residual starting materials in illicit preparations have been associated with severe dermatological effects and extensive tissue necrosis. Desomorphine is not well studied, and there are limited reports concerning its pharmacology or detection in biological matrices. Immunoassays are widely relied upon for both antemortem and postmortem toxicology screening. Although desomorphine is an opioid of the phenanthrene-type, its ability to bind to conventional opioid antibodies has not been described. In this report we describe the cross-reactivity of desomorphine using six commercially available enzyme-linked immunosorbent assays (Immunalysis Opiates Direct ELISA, Immunalysis Oxycodone/Oxymorphone Direct ELISA, Randox Opiate ELISA, OraSure Technologies OTI Opiate Micro-plate EIA, Neogen Opiate Group ELISA and Neogen Oxycodone/Oxymorphone ELISA). Cross-reactivites were highly variable between assays, ranging from 77 to desomorphine than those directed towards oxycodone. The Immunalysis Opiates Direct ELISA produced the greatest cross-reactivity, although several of the assays evaluated produced cross-reactivity of a sufficient magnitude to be effective for desomorphine screening. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  10. Direct Competitive Enzyme-Linked Immunosorbent Assay (ELISA).

    Science.gov (United States)

    Kohl, Thomas O; Ascoli, Carl A

    2017-07-05

    The competitive enzyme-linked immunosorbent assay (ELISA) (cELISA; also called an inhibition ELISA) is designed so that purified antigen competes with antigen in the test sample for binding to an antibody that has been immobilized in microtiter plate wells. The same concept works if the immobilized molecule is antigen and the competing molecules are purified labeled antibody versus antibody in a test sample. Direct cELISAs incorporate labeled antigen or antibody, whereas indirect assay configurations use reporter-labeled secondary antibodies. The cELISA is very useful for determining the concentration of small-molecule antigens in complex sample mixtures. In the direct cELISA, antigen-specific capture antibody is adsorbed onto the microtiter plate before incubation with either known standards or unknown test samples. Enzyme-linked antigen (i.e., labeled antigen) is also added, which can bind to the capture antibody only when the antibody's binding site is not occupied by either the antigen standard or antigen in the test samples. Unbound labeled and unlabeled antigens are washed away and substrate is added. The amount of antigen in the standard or the test sample determines the amount of reporter-labeled antigen bound to antibody, yielding a signal that is inversely proportional to antigen concentration within the sample. Thus, the higher the antigen concentration in the test sample, the less labeled antigen is bound to the capture antibody, and hence the weaker is the resultant signal. © 2017 Cold Spring Harbor Laboratory Press.

  11. Methodology for determination of plasma cortisol in fish using Competitive Enzyme-Linked Immunosorbent Assay (ELISA)

    DEFF Research Database (Denmark)

    Velasco-Santamaría, Yohana M.; Cruz-Casallas, Pablo E.

    2007-01-01

    Objective. To determine plasma cortisol procedure in fish using competitive enzymelinked immunosorbent assay (ELISA). Materials and methods. Two plasma samples of juveniles rainbow trout Oncorhynchus mykiss were analized by using ELISA human kit for cortisol assay. For standard curve calibration...

  12. Enzyme-linked immunosorbent assays for Z-DNA.

    Science.gov (United States)

    Thomas, M J; Strobl, J S

    1988-10-01

    Dot blot and transblot enzyme-linked immunosorbent assays (e.l.i.s.a.) are described which provide sensitive non-radioactive methods for screening Z-DNA-specific antisera and for detecting Z-DNA in polydeoxyribonucleotides and supercoiled plasmids. In the alkaline phosphatase dot blot e.l.i.s.a., Z-DNA, Br-poly(dG-dC).poly(dG-dC), or B-DNA, poly(dG-dC).poly(dG-dC), poly(dA-dT).poly(dA-dT), Br-poly(dI-dC).poly(dI-dC), or salmon sperm DNA were spotted onto nitrocellulose discs and baked. The e.l.i.s.a. was conducted in 48-well culture dishes at 37 degrees C using a rabbit polyclonal antiserum developed against Br-poly(dG-dC).poly(dG-dC), an alkaline phosphatase-conjugated second antibody, and p-nitrophenol as the substrate. Under conditions where antibody concentrations were not limiting, alkaline phosphatase activity was linear for 2 h. Dot blot e.l.i.s.a. conditions are described which allow quantification of Z-DNA [Br-poly(dG-dC).poly(dG-dC)] within the range 5-250 ng. Dot blot and transblot horseradish peroxidase e.l.i.s.a. are described that detect Z-DNA within supercoiled plasmid DNAs immobilized on diazophenylthioether (DPT) paper. In the transblot e.l.i.s.a., plasmid pUC8 derivatives containing 16, 24, or 32 residues of Z-DNA were electrophoresed in agarose gels and electrophoretically transferred to DPT paper. Z-DNA-antibody complexes were detected by the horseradish peroxidase-catalysed conversion of 4-chloro-1-naphthol to a coloured product that was covalently bound to the DPT paper. Z-DNA antibody reactivity was specific for supercoiled Z-DNA containing plasmids after removal of the antibodies cross-reactive with B-DNA by absorption onto native DNA-cellulose. The transblot e.l.i.s.a. was sensitive enough to detect 16 base pairs of alternating G-C residues in 100 ng of pUC8 DNA.

  13. Metal-amplified Density Assays, (MADAs), including a Density-Linked Immunosorbent Assay (DeLISA).

    Science.gov (United States)

    Subramaniam, Anand Bala; Gonidec, Mathieu; Shapiro, Nathan D; Kresse, Kayleigh M; Whitesides, George M

    2015-02-21

    This paper reports the development of Metal-amplified Density Assays, or MADAs - a method of conducting quantitative or multiplexed assays, including immunoassays, by using Magnetic Levitation (MagLev) to measure metal-amplified changes in the density of beads labeled with biomolecules. The binding of target analytes (i.e. proteins, antibodies, antigens) to complementary ligands immobilized on the surface of the beads, followed by a chemical amplification of the binding in a form that results in a change in the density of the beads (achieved by using gold nanoparticle-labeled biomolecules, and electroless deposition of gold or silver), translates analyte binding events into changes in density measureable using MagLev. A minimal model based on diffusion-limited growth of hemispherical nuclei on a surface reproduces the dynamics of the assay. A MADA - when performed with antigens and antibodies - is called a Density-Linked Immunosorbent Assay, or DeLISA. Two immunoassays provided a proof of principle: a competitive quantification of the concentration of neomycin in whole milk, and a multiplexed detection of antibodies against Hepatitis C virus NS3 protein and syphilis T. pallidum p47 protein in serum. MADAs, including DeLISAs, require, besides the requisite biomolecules and amplification reagents, minimal specialized equipment (two permanent magnets, a ruler or a capillary with calibrated length markings) and no electrical power to obtain a quantitative readout of analyte concentration. With further development, the method may be useful in resource-limited or point-of-care settings.

  14. A murine monoclonal antibody based enzyme-linked immunosorbent assay for almond (Prunus dulcis L.) detection.

    Science.gov (United States)

    Su, Mengna; Venkatachalam, Mahesh; Liu, Changqi; Zhang, Ying; Roux, Kenneth H; Sathe, Shridhar K

    2013-11-13

    A sandwich enzyme-linked immunosorbent assay (ELISA) using anti-almond soluble protein rabbit polyclonal antibodies as capture antibodies and murine monoclonal antibody 4C10 as the detection antibodies was developed. The assay is specific and sensitive (3-200 ng almond protein/mL) for almond detection. The standardized assay is accurate (assay variability assay did not register any cross-reactivity with the tested food matrices, suggesting the assay to be almond amandin specific. The assay could detect the presence of declared almond in the tested matched commercial samples. Further, the assay reliably detected the presence of almonds in the laboratory prepared food samples spiked with almond flour.

  15. Use of enzyme-linked immunosorbent assay and dipstick assay for detection of Strongyloides stercoralis infection in humans

    NARCIS (Netherlands)

    van Doorn, H. Rogier; Koelewijn, Rob; Hofwegen, Henk; Gilis, Henk; Wetsteyn, Jose C. F. M.; Wismans, Pieter J.; Sarfati, Claudine; Vervoort, Tony; van Gool, Tom

    2007-01-01

    A homemade enzyme-linked immunosorbent assay (ELISA) (Academic Medical Center ELISA [AMC-ELISA]) and a dipstick assay for the detection of anti-Strongyloides stercoralis antibodies in serum were developed and evaluated together with two commercially available ELISAs (IVD-ELISA [IVD Research, Inc.

  16. Immobilization of proteins onto microbeads using a DNA binding tag for enzymatic assays.

    Science.gov (United States)

    Kojima, Takaaki; Mizoguchi, Takuro; Ota, Eri; Hata, Jumpei; Homma, Keisuke; Zhu, Bo; Hitomi, Kiyotaka; Nakano, Hideo

    2016-02-01

    A novel DNA-binding protein tag, scCro-tag, which is a single-chain derivative of the bacteriophage lambda Cro repressor, has been developed to immobilize proteins of interest (POI) on a solid support through binding OR consensus DNA (ORC) that is tightly bound by the scCro protein. The scCro-tag successfully bound a transglutaminase 2 (TGase 2) substrate and manganese peroxidase (MnP) to microbeads via scaffolding DNA. The resulting protein-coated microbeads can be utilized for functional analysis of the enzymatic activity using flow cytometry. The quantity of bead-bound proteins can be enhanced by increasing the number of ORCs. In addition, proteins with the scCro-tag that were synthesized using a cell-free protein synthesis system were also immobilized onto the beads, thus indicating that this bead-based system would be applicable to high-throughput analysis of various enzymatic activities. Copyright © 2015 The Society for Biotechnology, Japan. Published by Elsevier B.V. All rights reserved.

  17. Prussian blue nanoparticles as a catalytic label in a sandwich nanozyme-linked immunosorbent assay

    Czech Academy of Sciences Publication Activity Database

    Farka, Z.; Čunderlová, V.; Horáčková, V.; Pastucha, M.; Mikušová, Z.; Hlaváček, Antonín; Skládal, P.

    2018-01-01

    Roč. 90, č. 3 (2018), s. 2348-2354 ISSN 0003-2700 R&D Projects: GA MŠk(CZ) LM2015043; GA ČR(CZ) GBP206/12/G014 Institutional support: RVO:68081715 Keywords : catalytic nanoparticle * immunosorbent assays * nanoparticles Subject RIV: CB - Analytical Chemistry, Separation OBOR OECD: Analytical chemistry Impact factor: 6.320, year: 2016

  18. Development of an Enzyme Linked Immunosorbent Assay to Detect Chicken Parvovirus Specific Antibodies

    Science.gov (United States)

    Here we report the development and application of an enzyme linked immunosorbent assay to detect parvovirus-specific antibodies in chicken sera. We used an approach previously described for other parvoviruses to clone and express viral structural proteins in insect cells from recombinant baculovirus...

  19. Application of an improved enzyme-linked immunosorbent assay method for serological diagnosis of canine leishmaniasis

    NARCIS (Netherlands)

    Santarém, Nuno; Silvestre, Ricardo; Cardoso, Luís; Schallig, Henk; Reed, Steven G.; Cordeiro-da-Silva, Anabela

    2010-01-01

    Accurate diagnosis of canine leishmaniasis (CanL) is essential toward a more efficient control of this zoonosis, but it remains problematic due to the high incidence of asymptomatic infections. In this study, we present data on the development of enzyme-linked immunosorbent assay (ELISA)-based

  20. A Direct, Competitive Enzyme-Linked Immunosorbent Assay (ELISA) as a Quantitative Technique for Small Molecules

    Science.gov (United States)

    Powers, Jennifer L.; Rippe, Karen Duda; Imarhia, Kelly; Swift, Aileen; Scholten, Melanie; Islam, Naina

    2012-01-01

    ELISA (enzyme-linked immunosorbent assay) is a widely used technique with applications in disease diagnosis, detection of contaminated foods, and screening for drugs of abuse or environmental contaminants. However, published protocols with a focus on quantitative detection of small molecules designed for teaching laboratories are limited. A…

  1. Prussian blue nanoparticles as a catalytic label in a sandwich nanozyme-linked immunosorbent assay

    Czech Academy of Sciences Publication Activity Database

    Farka, Z.; Čunderlová, V.; Horáčková, V.; Pastucha, M.; Mikušová, Z.; Hlaváček, Antonín; Skládal, P.

    2018-01-01

    Roč. 90, č. 3 (2018), s. 2348-2354 ISSN 0003-2700 R&D Projects: GA MŠk(CZ) LM2015043; GA ČR(CZ) GBP206/12/G014 Institutional support: RVO:68081715 Keywords : catalytic nanoparticle * immunosorbent assays * nanoparticles Subject RIV: CB - Analytical Chemistry , Separation OBOR OECD: Analytical chemistry Impact factor: 6.320, year: 2016

  2. Indirect solid-phase immunosorbent assay for detection of arenavirus antigens and antibodies

    Energy Technology Data Exchange (ETDEWEB)

    Ivanov, A P; Rezapkin, G V; Dzagurova, T K; Tkachenko, E A [Institute of Poliomyelitis anU Viral Encephalities of the U.S.S.R. Academy of Medical Sciences, Moscow

    1984-05-01

    Indirect enzyme-linked immunosorbent assay (ELISA) and solid phase radioimmunoassay (SPRIA) using either enti-human or anti-mouse IgG labelled with horseradish peroxidase and /sup 125/I, respectively, were developed for the detection of Junin, Machupo, Tacaribe, Amapari, Tamiami, Lassa and LCM arenaviruses. Both methods allow high sensitivity detection of arenavirus antigens and antibodies.

  3. ANALYSIS OF SOIL AND DUST SAMPLES FOR POLYCHLORINATED BIPHENYLS BY ENZYME LINKED IMMUNOSORBENT ASSAY (ELISA)

    Science.gov (United States)

    An inhibition enzyme-linked immunosorbent assay (ELISA) was used to determine polychlorinated biphenyls (PCBs) in house dust and soil. Soil and house dust samples were analyzed for PCB by both gas chromatography/electron capture detection (GC/ECD) and ELISA methods. A correlati...

  4. rK39 enzyme-linked immunosorbent assay for diagnosis of Leishmania donovani infection

    NARCIS (Netherlands)

    Zijlstra, E. E.; Daifalla, N. S.; Kager, P. A.; Khalil, E. A.; El-Hassan, A. M.; Reed, S. G.; Ghalib, H. W.

    1998-01-01

    The rK39 enzyme-linked immunosorbent assay (ELISA) was compared with the direct agglutination test (DAT) for Leishmania donovani infection in the Sudan. rK39 ELISA proved more sensitive than DAT in diagnosis of kala-azar (93 and 80%, respectively); both tests may remain positive up to 24 months

  5. A new method for the production of a magnetic immunosorbent used in radioimmunoassay and immunoradiometric assay

    International Nuclear Information System (INIS)

    Toth, G.; Keszei, V.; Sarandi, I.

    1994-01-01

    A method has been developed enabling the direct coupling of first or second antibody to finely dispersed magnetite (Fe 3 O 4 ). The immunosorbent thus produced was applied in various radioimmunoassay systems (T3, T4, TSH, Cortisol) for the separation of bound and free antigens. The elimination of the need for 'precoating' the magnetic particles with a polymer as several advantages. One of them lies in the ease of one-step production of the immunosorbent and other is the high antibody/magnetic ratio. The influence of the concentration of the immunosorbent and detergent (TWEEN 20 or TRITON X-100) on the assay parameters (Bo, NSB, etc.) has been systematically investigated and the optimum concentration of the magnetizable particles and detergent has been determined. The reliability of magnetic separation has been validated by comparing it with the conventional PEG separation method. (author) 13 refs.; 17 figs.; 9 tabs

  6. Quantum dot-linked immunosorbent assay (QLISA) using orientation-directed antibodies.

    Science.gov (United States)

    Suzuki, Miho; Udaka, Hikari; Fukuda, Takeshi

    2017-09-05

    An approach similar to the enzyme-linked immunosorbent assay (ELISA), with the advantage of saving time and effort but exhibiting high performance, was developed using orientation-directed half-part antibodies immobilized on CdSe/ZnS quantum dots. ELISA is a widely accepted assay used to detect the presence of a target substance. However, it takes time to quantify the target with specificity and sensitivity owing to signal amplification. In this study, CdSe/ZnS quantum dots are introduced as bright and photobleaching-tolerant fluorescent materials. Since hydrophilic surface coating of quantum dots rendered biocompatibility and functional groups for chemical reactions, the quantum dots were modified with half-sized antibodies after partial reduction. The half-sized antibody could be bound to a quantum dot through a unique thiol site to properly display the recognition domain for the core process of ELISA, which is an antigen-antibody interaction. The reducing conditions were investigated to generate efficient conjugates of quantum dots and half-sized antibodies. This was applied to IL-6 detection, as the quantification of IL-6 is significant owing to its close relationships with various biomedical phenomena that cause different diseases. An ELISA-like assay with CdSe/ZnS quantum dot institution (QLISA; Quantum dot-linked immunosorbent assay) was developed to detect 0.05ng/mL IL-6, which makes it sufficiently sensitive as an immunosorbent assay. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Evaluation of an enzyme-linked immunosorbent assay for determination of porcine haptoglobin

    DEFF Research Database (Denmark)

    Petersen, H. H.; Nielsen, J. P.; Jensen, A.L.

    2001-01-01

    An enzyme-linked immunosorbent assay for quantification of haptoglobin in porcine serum was evaluated. Tbe detection limit when expressed as the estimated concentration of a blank sample was 0.0003 mg/ml. The precision of the assay was acceptable with intra-assay coefficients of variation below 4...... % and inter-assay coefficient of variation below 5 % for serum concentrations ranging from 1.0 mg/ml and above. For samples with a concentration below 0.8 mg/ml, the inter-assay coefficient of variation was above 10 %. The assay maintained linearity under dilution. Recovery was proportional. Haemolysis.......2. The maximum allowable analytical imprecision was 2.6 % and the maximum analytical inaccuracy was 9.9 %. The number of samples required to determine, the true haptoglobin value in an individual pig when accounting for the day-to-day fluctuation was 5. In conclusion, the haptoglobin assay was found...

  8. Bluetongue virus: comparative evaluation of enzyme-linked immunosorbent assay, immunodiffusion, and serum neutralization for detection of viral antibodies.

    OpenAIRE

    Poli, G; Stott, J; Liu, Y S; Manning, J S

    1982-01-01

    Comparative studies on the detection of bovine serum immunoglobulin G antibodies to bluetongue virus with an enzyme-linked immunosorbent assay, an immunodiffusion method, and a serum neutralization assay demonstrated complete concordance between the enzyme-linked immunosorbent assay and the serum neutralization assay results. However, the immunodiffusion method failed to detect bluetongue virus antibody in a substantial number of sera found to possess bluetongue virus immunoglobulin G with th...

  9. Rapid enzyme-linked immunosorbent assay (ELISA) for Aspergillus fumigatus antibodies.

    OpenAIRE

    Richardson, M D; Stubbins, J M; Warnock, D W

    1982-01-01

    A rapid enzyme-linked immunosorbent assay (ELISA) where component incubation periods were shortened to one hour, was compared with agar gel double diffusion (AGDD) and a standard ELISA procedure for detecting antibodies to Aspergillus fumigatus in 28 asthmatic patients with suspected allergic aspergillosis. Using two A fumigatus antigens the rapid ELISA compared well with AGDD and the standard ELISA method. Eleven sera that reacted with both antigens in AGDD were all positive against antigen ...

  10. Validation of a KHV antibody enzyme-linked immunosorbent assay (ELISA).

    Science.gov (United States)

    Bergmann, S M; Wang, Q; Zeng, W; Li, Y; Wang, Y; Matras, M; Reichert, M; Fichtner, D; Lenk, M; Morin, T; Olesen, N J; Skall, H F; Lee, P-Y; Zheng, S; Monaghan, S; Reiche, S; Fuchs, W; Kotler, M; Way, K; Bräuer, G; Böttcher, K; Kappe, A; Kielpinska, J

    2017-11-01

    Koi herpesvirus (KHV) causes KHV disease (KHVD). The virus is highly contagious in carp or koi and can induce a high mortality. Latency and, in some cases, a lack of signs presents a challenge for virus detection. Appropriate immunological detection methods for anti-KHV antibodies have not yet been fully validated for KHV. Therefore, it was developed and validated an enzyme-linked immunosorbent assay (ELISA) to detect KHV antibodies. The assay was optimized with respect to plates, buffers, antigens and assay conditions. It demonstrated high diagnostic and analytical sensitivity and specificity and was particularly useful at the pond or farm levels. Considering the scale of the carp and koi industry worldwide, this assay represents an important practical tool for the indirect detection of KHV, also in the absence of clinical signs. © 2017 John Wiley & Sons Ltd.

  11. Biotin/avidin sandwich enzyme-linked immunosorbent assay for Culicidae mosquito blood meal identification

    Directory of Open Access Journals (Sweden)

    A. M. Marassá

    2008-01-01

    Full Text Available The knowledge of mosquitoes Culicidae host feeding patterns is basic to understand the roles of different species and to indicate their importance in the epidemiology of arthropod-borne diseases. A laboratory assay was developed aiming at standardizing the biotin-avidin sandwich enzyme-linked immunosorbent assay, which was unprecedented for mosquito blood meal identification. The enzyme-linked immunosorbent assay (ELISA activity was evaluated by the detection of titers on each sample of the 28 blood-fed Culex quinquefasciatus. In light of the high sensitivity that the technique permits, by means of small quantities of specific antibodies commercially provided and phosphatase substrate which reinforces additional dilutions, human and rat blood meals were readily identified in all laboratory-raised Culex quinquefasciatus tested. The assay was effective to detect human blood meal dilutions up to 1:4,096, which enables the technique to be applied in field studies. Additionally, the present results indicate a significant difference between the detection patterns recorded from human blood meal which corroborate the results of host feeding patterns.

  12. Monoclonal antibodies against human angiotensinogen, their characterization and use in an angiotensinogen enzyme linked immunosorbent assay.

    Science.gov (United States)

    Rubin, I; Lykkegaard, S; Olsen, A A; Selmer, J; Ballegaard, M

    1988-01-01

    Monoclonal antibodies were produced against human angiotensinogen. An enzyme linked immunosorbent assay (ELISA) was developed using a high affinity monoclonal antibody as catching antibody and a polyclonal rabbit anti human angiotensinogen antibody as detecting antibody in a "sandwich" ELISA. Linear range of the ELISA was 15-450 pmol/l of human angiotensinogen. Intra- and inter- assay variation coefficients were in the range of 2% to 8%. A correlation coefficient, r = 0.97, (n = 20), with values obtained by radioimmunoassay. This correlation coefficient, obtained by using both normal and pregnant sera, confirmed that the ELISA fulfill the requirements for clinical useful assay. Characterization of the antibodies were performed with respect to affinity constant and epitopes.

  13. Development of an enzyme-linked immunosorbent assay method to detect mustard protein in mustard seed oil

    NARCIS (Netherlands)

    Koppelman, S.J.; Vlooswijk, R.; Bottger, G.; Duijn, G. van; Schaft, P. van der; Dekker, J.; Bemgen, H. van

    2007-01-01

    An enzyme-linked immunosorbent assay for the detection of mustard protein was developed. The assay is based on a polyclonal antiserum directed against a mixture of mustard proteins raised in rabbits. The assay has a detection limit of 1.5 ppm (milligrams per kilogram) and is suitable for the

  14. The use of subcutaneous fat tissue for amyloid typing by enzyme-linked immunosorbent assay

    DEFF Research Database (Denmark)

    Olsen, K E; Sletten, K; Westermark, Per

    1999-01-01

    for typing the most common systemic amyloidoses of AL, AA, and transthyretin types by enzyme-linked immunosorbent assay (ELISA), using abdominal wall subcutaneous fat biopsy specimens. The method was tested on 21 abdominal fat biopsy specimens that were sent to the laboratory. Of these, 15 contained amyloid......The amyloidoses are biochemically heterogeneous diseases with pathophysiologic deposits of various proteins. The clinical course, prognosis, and therapy are different for each type of amyloidosis and, therefore, a type-specific diagnosis is demanded as early as possible. We describe a method...

  15. Review on enzyme-linked immunosorbent assays for sulfonamide residues in edible animal products.

    Science.gov (United States)

    Zhang, Hongyan; Wang, Shuo

    2009-10-31

    The current status of enzyme-linked immunosorbent assays (ELISAs) for sulfonamides in edible animal products is reviewed. The attention was focused on the design and synthesis of haptens, conjugation to carrier protein, production of antibody, application of homologous and heterologous systems, as well as the molecular modeling of the haptens and sulfonamides. Researches have shown that sulfonamides seem to be particularly resistant to attempts to produce broad specificity antibodies. By summarizing the available research on sulfonamide ELISAs, it is hoped that it can be considered as a basis for further investigation aimed at developing the most efficient approaches for detection.

  16. Two new automated, compared with two enzyme-linked immunosorbent, antimüllerian hormone assays.

    Science.gov (United States)

    Nelson, Scott M; Pastuszek, Ewa; Kloss, Grzegorz; Malinowska, Iwona; Liss, Joanna; Lukaszuk, Aron; Plociennik, Lukasz; Lukaszuk, Krzysztof

    2015-10-01

    To compare new automated antimüllerian hormone (AMH) assay performance characteristics from the new automated Elecsys AMH (Roche; Elecsys) and Access AMH (Beckman Coulter; Access) assays with the existing AMH Gen II ELISA (enzyme-linked immunosorbent assay; Gen II; Beckman Coulter) and AMH ELISA (Ansh Labs) assays. Prospective assay evaluation. University-affiliated clinical chemistry laboratory. Patients referred for serum AMH measurement (n = 83) before start of in vitro fertilization cycle between September 2014 and October 2014. None. Serum AMH concentration. Intra-assay coefficients of variation were low; Ansh ≤ 9.0%; Gen II ≤ 5.8%; Access ≤ 10.7%; and Elecsys ≤ 2.8%. The Passing-Bablok regression equations (pmol/L) were y (Access) = 0.128 + (0.781 × Gen II); and y (Access) = 0.302 + (0.742 x Ansh). For y (Elecys) = 0.087 + (0.729 x Gen II) and y (Elecys) = 0.253 + (0.688 x Ansh Labs). For y (Elecys) = 0.943 - (0.037 × Access). For all the assays, AMH exhibited a moderate positive correlation with AFC (r = 0.62-0.64); number of cumulus oocyte complexes (r = 0.60-0.64); and metaphase II oocytes (r = 0.48-0.50). Accuracy of pregnancy prediction, as determined by area under the receiver operating characteristic curve, was uniformly low for all assays (0.62-0.63). The novel automated assays exhibit strong concordance in calibration, but derived values are substantially lower than those obtained from pre-existing assays, with assay-specific interpretation required for routine clinical use. These results highlight the need for an international standard of measurement of AMH. Copyright © 2015 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  17. Development and customization of a color-coded microbeads-based assay for drug resistance in HIV-1 reverse transcriptase.

    Science.gov (United States)

    Gu, Lijun; Kawana-Tachikawa, Ai; Shiino, Teiichiro; Nakamura, Hitomi; Koga, Michiko; Kikuchi, Tadashi; Adachi, Eisuke; Koibuchi, Tomohiko; Ishida, Takaomi; Gao, George F; Matsushita, Masaki; Sugiura, Wataru; Iwamoto, Aikichi; Hosoya, Noriaki

    2014-01-01

    Drug resistance (DR) of HIV-1 can be examined genotypically or phenotypically. Although sequencing is the gold standard of the genotypic resistance testing (GRT), high-throughput GRT targeted to the codons responsible for DR may be more appropriate for epidemiological studies and public health research. We used a Japanese database to design and synthesize sequence-specific oligonucleotide probes (SSOP) for the detection of wild-type sequences and 6 DR mutations in the clade B HIV-1 reverse transcriptase region. We coupled SSOP to microbeads of the Luminex 100 xMAP system and developed a GRT based on the polymerase chain reaction (PCR)-SSOP-Luminex method. Sixteen oligoprobes for discriminating DR mutations from wild-type sequences at 6 loci were designed and synthesized, and their sensitivity and specificity were confirmed using isogenic plasmids. The PCR-SSOP-Luminex DR assay was then compared to direct sequencing using 74 plasma specimens from treatment-naïve patients or those on failing treatment. In the majority of specimens, the results of the PCR-SSOP-Luminex DR assay were concordant with sequencing results: 62/74 (83.8%) for M41, 43/74 (58.1%) for K65, 70/74 (94.6%) for K70, 55/73 (75.3%) for K103, 63/73 (86.3%) for M184 and 68/73 (93.2%) for T215. There were a number of specimens without any positive signals, especially for K65. The nucleotide position of A2723G, A2747G and C2750T were frequent polymorphisms for the wild-type amino acids K65, K66 and D67, respectively, and 14 specimens had the D67N mutation encoded by G2748A. We synthesized 14 additional oligoprobes for K65, and the sensitivity for K65 loci improved from 43/74 (58.1%) to 68/74 (91.9%). We developed a rapid high-throughput assay for clade B HIV-1 DR mutations, which could be customized by synthesizing oligoprobes suitable for the circulating viruses. The assay could be a useful tool especially for public health research in both resource-rich and resource-limited settings.

  18. Quantitation of the receptor for urokinase plasminogen activator by enzyme-linked immunosorbent assay

    DEFF Research Database (Denmark)

    Rønne, E; Behrendt, N; Ploug, M

    1994-01-01

    variant of uPAR, suPAR, has been constructed by recombinant technique and the protein content of a purified suPAR standard preparation was determined by amino acid composition analysis. The sensitivity of the assay (0.6 ng uPAR/ml) is strong enough to measure uPAR in extracts of cultured cells and cancer......Binding of the urokinase plasminogen activator (uPA) to a specific cell surface receptor (uPAR) plays a crucial role in proteolysis during tissue remodelling and cancer invasion. An immunosorbent assay for the quantitation of uPAR has now been developed. This assay is based on two monoclonal...... antibodies recognizing the non-ligand binding part of this receptor, and it detects both free and occupied uPAR, in contrast to ligand-binding assays used previously. In a variant of the assay, the occupied fraction of uPAR is selectively detected with a uPA antibody. To be used as a standard, a soluble...

  19. Development of an enzyme-linked immunosorbent assay for the detection of ciguatoxin in fish tissue using chicken immunoglobulin Y.

    Science.gov (United States)

    Empey Campora, Cara; Hokama, Yoshitsugi; Yabusaki, Kenichi; Isobe, Minoru

    2008-01-01

    A sandwich enzyme-linked immunosorbent assay was developed to detect ciguatoxin (CTX) in fish tissue. The assay utilizes two antibodies, chicken immunoglobulin Y specific to the ABCD domain of CTX and a mouse monoclonal immunoglobulin G-horseradish peroxidase conjugate specific to the JKLM domain of CTX. The sensitivity, working range, cross reactivity, accuracy, precision, and reproducibility were examined.

  20. Comparative study of the enzyme linked immunosorbent assay (ELISA) and two radioimmunoassays (RIA'S) for in-sulin

    Energy Technology Data Exchange (ETDEWEB)

    Klimes, I; Jurcovicova, J; Palkovic, M [Slovenska Akademia Vied, Bratislava (Czechoslovakia). Ustav Experimentalnej Endokrinologie

    1978-06-30

    The results of the quality control tests for enzyme linked immunosorbent assay (ELISA) were compared with the results of two different radioimmunoassays (RIA'S) for insulin. Using the manufacturer's procedure for the ELISA kit we found that the analytical variables such as assay sensitivity, recovery study and the 50% binding intercept were in good agreement with those obtained with the RIA method.

  1. Improvement of an enzyme immunosorbent assay for detecting antibodies against Dioctophyma renale.

    Science.gov (United States)

    Pedrassani, Daniela; do Nascimento, Adjair Antonio; André, Marcos Rogério; Machado, Rosangela Zacarias

    2015-09-15

    An available enzyme-linked immunosorbent assay (ELISA) was studied for the detection of anti-Dioctophyma renale antibodies in the sera of dogs using, detection of parasite eggs in urine sediment as a reference test. ELISA uses a soluble antigenic preparation of esophagus of D. renale and the optimal dilutions of the antigen, serum and conjugate were determined by means of checker board titration, using positive (n=13) and negative (n=27) reference serum. The specificity and sensitivity of the ELISA were 93.8% and 92.3% respectively and the kappa index was good (0.76). These results suggest that ELISA described may prove to be an effective serological test for detecting dogs infected and exposed to this parasite mainly dogs that are not eliminating parasite eggs through their urine. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. An enzyme-linked immunosorbent assay for bromodeoxyuridine incorporation using fixed microcultures

    International Nuclear Information System (INIS)

    Muir, D.; Varon, S.; Manthorpe, M.

    1990-01-01

    We report a quantitative method by which a single microculture can be examined for cell morphology; cell number; DNA synthesis; and expression of cell antigens. This method first involves measuring by enzyme-linked immunosorbent assay (ELISA) the total bromodeoxyuridine (BrdU) incorporation into DNA by monolayer microcultures. The BrdU-ELISA measurement was followed by simultaneous immunostaining for BrdU-positive nuclei and for a cytoplasmic antigen. The method was applied to the measurement of mitogen-induced proliferation of rat sciatic nerve Schwann cell and cerebral astroglia microcultures. The ELISA measurement of BrdU incorporation compares favorably with measurements of tritiated thymidine incorporation and offers the additional advantages that the same microculture can subsequently be examined for cell number, for cell morphology, and for the percentage of cells having BrdU-labeled nuclei and other antigens

  3. An enzyme-linked immunosorbent assay for bromodeoxyuridine incorporation using fixed microcultures

    Energy Technology Data Exchange (ETDEWEB)

    Muir, D.; Varon, S.; Manthorpe, M. (Univ. of California, San Diego, La Jolla (USA))

    1990-03-01

    We report a quantitative method by which a single microculture can be examined for cell morphology; cell number; DNA synthesis; and expression of cell antigens. This method first involves measuring by enzyme-linked immunosorbent assay (ELISA) the total bromodeoxyuridine (BrdU) incorporation into DNA by monolayer microcultures. The BrdU-ELISA measurement was followed by simultaneous immunostaining for BrdU-positive nuclei and for a cytoplasmic antigen. The method was applied to the measurement of mitogen-induced proliferation of rat sciatic nerve Schwann cell and cerebral astroglia microcultures. The ELISA measurement of BrdU incorporation compares favorably with measurements of tritiated thymidine incorporation and offers the additional advantages that the same microculture can subsequently be examined for cell number, for cell morphology, and for the percentage of cells having BrdU-labeled nuclei and other antigens.

  4. Determination of PCBs in fish using enzyme-linked immunosorbent assay (ELISA)

    Science.gov (United States)

    Lasrado, J.A.; Santerre, C.R.; Zajicek, J.L.; Stahl, J.R.; Tillitt, D.E.; Deardorff, D.

    2003-01-01

    Polychlorinated biphenyls (PCBs) were determined in fish tissue using an enzyme-linked immunosorbent assay (ELISA). Standard curves for Aroclor 1248, 1254, and 1260 in catfish tissue were developed with ranges from 0.05 to 0.5 ppm and 0.5 to 5.0 ppm. Wild fish were initially analyzed using gas chromatography/electron-capture detection (GC/ECD) and those having residues within the standard curve ranges were analyzed with ELISA. Results obtained using ELISA and GC/ECD were not significantly different (p < 0.05) from 0.05 to 0.5 ppm. From 0.5 to 5.0 ppm, the standard curve for Aroclor 1254 was the best predictor of total PCB in wild fish samples.

  5. Radiometric immunosorbent assay for the detection of anti-hormone-binding protein antibodies

    International Nuclear Information System (INIS)

    Pierce, E.A.; Dame, M.C.; DeLuca, H.F.

    1986-01-01

    A radiometric immunosorbent assay (RISA) for the detection of monoclonal antibodies to hormone-binding proteins has been developed. The assay involves incubating hybridoma supernatants in microtiter wells that have been coated with goat anti-mouse IgG antibodies. Any mouse IgG in the test supernatant is thus specifically retained in the wells. Radioactive ligand-binding protein complexes are then incubated in the wells. The presence of anti-binding protein antibodies in the supernatant is indicated by specific retention of radioactive ligand-binding protein complexes in the wells. Crude antigen preparations, such as tissue homogenates, can be used to detect antibodies. The assay is capable of detecting antibody at concentrations 20 ng/ml (approx. 100 pM IgG). The RISA has been used successfully to screen for monoclonal antibodies to the intracellular receptor for 1,25-dihydroxyvitamin D 3 and should be useful for the detection of antibodies to ligand-binding proteins in general

  6. Detection of antibodies to the extractable nuclear antigens by enzyme linked immunosorbent assay

    International Nuclear Information System (INIS)

    Aziz, Khalil A.; Fzizal, Abul A.

    2005-01-01

    Anti-extractable nuclear antigen (ENA) antibodies are a group of autoantibodies that are directed against various components of the cell nucleus. Antibodies to these antigens are closely associated with connective tissue disease. Early diagnosis of these diseases can prove very difficult and therefore clinicians rely on the use of anti-ENA antibody testing for the exclusion. Old methods of testing are time consuming and require great skills. For these reasons clinical immunology laboratories are switching to testing for anti-ENA antibodies by enzyme linked immunosorbent assay (ELISA). The latter assays are more sensitive and require little skills. In the present study we have investigated a number of different ELISA preparations. The study was conducted at Birmingham Heartlands Hospital during the period 2003. We tested a number of ENA-positive and negative samples using 3 different commercial ELISA preparations and compared the results with traditional CCIE-assay. The present study revealed that some ELISA preparations can be more sensitive than CCIE method. Laboratories still using later method should switch to ELISA. However it is important that laboratories evaluate a long range of different ELISA preparations before selecting the most optimal one. In addition it is recommended that laboratories then audit results in order to determine true significance of such results. Finally until the true significance of ELISA generated results is known, positive ENA-results should be interpreted in conjunction with the clinical picture and this would require close liaison in between the clinical immunology laboratory and clinicians

  7. Assessing protein oxidation by inorganic nanoparticles with enzyme-linked immunosorbent assay (ELISA).

    Science.gov (United States)

    Sun, Wenjie; Luna-Velasco, Antonia; Sierra-Alvarez, Reyes; Field, Jim A

    2013-03-01

    Growth in the nanotechnology industry is leading to increased production of engineered nanoparticles (NPs). This has given rise to concerns about the potential adverse and toxic effects to biological system and the environment. An important mechanism of NP toxicity is oxidative stress caused by the formation of reactive oxygen species (ROS) or via direct oxidation of biomolecules. In this study, a protein oxidation assay was developed as an indicator of biomolecule oxidation by NPs. The oxidation of the protein, bovine serum albumin (BSA) was evaluated with an enzyme-linked immunosorbent assay (ELISA) to measure the protein carbonyl derivatives formed from protein oxidation. The results showed that some NPs such as Cu(0), CuO, Mn(2)O(3), and Fe(0) caused oxidation of BSA; whereas, many of the other NPs tested were not reactive or very slowly reactive with BSA. The mechanisms involved in the oxidation of BSA protein by the reactive NPs could be attributed to the combined effects of ROS-dependent and direct protein oxidation mechanisms. The ELISA assay is a promising method for the assessment of protein oxidation by NPs, which can provide insights on NP toxicity mechanisms. Copyright © 2012 Wiley Periodicals, Inc.

  8. Development of an enzyme-linked immunosorbent assay for the detection of dicamba.

    Science.gov (United States)

    Clegg, B S; Stephenson, G R; Hall, J C

    2001-05-01

    A competitive indirect enzyme-linked immunosorbent assay (CI-ELISA) was developed to quantitate the herbicide dicamba (3,6-dichloro-2-methoxybenzoic acid) in water. The CI-ELISA has a detection limit of 2.3 microg L(-1) and a linear working range of 10--10000 microg L(-1) with an IC(50) value of 195 microg L(-1). The dicamba polyclonal antisera did not cross-react with a number of other herbicides tested but did cross-react with a dicamba metabolite, 5-hydroxydicamba, and structurally related chlorobenzoic acids. The assay was used to estimate quantitatively dicamba concentrations in water samples. Water samples were analyzed directly, and no sample preparation was required. To improve detection limits, a C(18) (reversed phase) column concentration step was devised prior to analysis, and the detection limits were increased by at least by 10-fold. After the sample preconcentration, the detection limit, IC(50), and linear working range were 0.23, 19.5, and 5-200 microg L(-1), respectively. The CI-ELISA estimations in water correlated well with those from gas chromatography-mass spectrometry (GC-MS) analysis (r(2) = 0.9991). This assay contributes to reducing laboratory costs associated with the conventional GC-MS residue analysis techniques for the quantitation of dicamba in water.

  9. Detection of thyroid stimulating hormone receptor antibodies (TRAb) by radioreceptor assay (RRA) and enzyme-linked immunosorbent assay (ELISA)

    International Nuclear Information System (INIS)

    Dumrongpisutikul, S.; Tuchinda, S.

    1990-01-01

    Thyroid stimulating hormone receptor antibodies (TRAb) were determined in 100 patients using radioreceptor assay (RRA) and enzyme-linked immunosorbent assay (ELISA). The sensitivity of RRA and ELISA were found to be 70.6% and 88.2% respectively (n=51). The specificity of both assays were 100% (n=16). With RRA as the standard test the sensitivity and specificity of ELISA were 75.8% and 86.8%. In the untreated hyperthyroid the RRA result which expressed as % specific 125 I-TSH inhibition was 33.6% (n=51), decline to 26.9% in the treated hyperthyroid (n=33) and 14.1% in the euthyroid (n=16). The mean 0.D 492nm of TRAb-ELISA were 0.861 in untreated hyperthyroid, 0.437 in treated hyperthyroid and 0.135 in euthyroid Phi coefficient analysis show that the RRA was 60.4% correlated to hyperthyroidism where as TRAb-ELISA was 80.1%

  10. Probe colorimeter for quantitating enzyme-linked immunosorbent assays and other colorimetric assays performed with microplates.

    Science.gov (United States)

    Ackerman, S B; Kelley, E A

    1983-03-01

    The performance of a fiberoptic probe colorimeter (model PC800; Brinkmann Instruments, Inc., Westbury, N.Y.) for quantitating enzymatic or colorimetric assays in 96-well microtiter plates was compared with the performances of a spectrophotometer (model 240; Gilford Instrument Laboratories, Inc., Oberlin, Ohio) and a commercially available enzyme immunoassay reader (model MR590; Dynatech Laboratories, Inc., Alexandria, Va.). Alkaline phosphatase-p-nitrophenyl phosphate in 3 M NaOH was used as the chromophore source. Six types of plates were evaluated for use with the probe colorimeter; they generated reproducibility values (100% coefficient of variation) ranging from 91 to 98% when one individual made 24 independent measurements on the same dilution of chromophore on each plate. Eleven individuals each performed 24 measurements with the colorimeter on either a visually light (absorbance of 0.10 at 420 nm) or a dark (absorbance of 0.80 at 420 nm) dilution of chromophore; reproducibilities averaged 87% for the light dilution and 97% for the dark dilution. When one individual measured the same chromophore sample at least 20 times in the colorimeter, in the spectrophotometer or in the enzyme immunoassay reader, reproducibility for each instrument was greater than 99%. Measurements of a dilution series of chromophore in a fixed volume indicated that the optical responses of each instrument were linear in a range of 0.05 to 1.10 absorbance units.

  11. Microbead agglutination based assays

    KAUST Repository

    Castro, David; Foulds, Ian G.; Kodzius, Rimantas

    2013-01-01

    A method for detecting the presence of an analyte in a sample can include adding a plurality of microparticles of a first-type to the sample, where each microparticle of the first-type includes a first binding partner configured to interact with at least a first portion of the analyte, adding a plurality of microparticles of a second-type to the sample, where each microparticle of the second-type includes a second binding partner configured to interact with at least a second portion of the analyte, the first portion of the analyte being different from the second portion of the analyte, and identifying an aggregate including at least one microparticle of the first-type, at least one microparticle of the second-type and the analyte, where the aggregate indicates the presence of the analyte.

  12. Microbead agglutination based assays

    KAUST Repository

    Castro, David

    2013-11-28

    A method for detecting the presence of an analyte in a sample can include adding a plurality of microparticles of a first-type to the sample, where each microparticle of the first-type includes a first binding partner configured to interact with at least a first portion of the analyte, adding a plurality of microparticles of a second-type to the sample, where each microparticle of the second-type includes a second binding partner configured to interact with at least a second portion of the analyte, the first portion of the analyte being different from the second portion of the analyte, and identifying an aggregate including at least one microparticle of the first-type, at least one microparticle of the second-type and the analyte, where the aggregate indicates the presence of the analyte.

  13. Comparison of two enzyme-linked immunosorbent assays and one rapid immunoblot assay for detection of herpes simplex virus type 2-specific antibodies in serum

    NARCIS (Netherlands)

    Groen, J; Van Dijk, G; Niesters, H G; Van Der Meijden, W I; Osterhaus, A D

    The sensitivities and specificities of three immunoassays for the detection of herpes simplex virus type 2 (HSV-2)-specific immunoglobulin G antibodies in serum, including the one-strip rapid immunoblot assay (RIBA; Chiron Corporation) and two indirect enzyme immunosorbent assays (EIA; Gull

  14. Phytochrome quantitation in crude extracts of Avena by enzyme-linked immunosorbent assay with monoclonal antibodies

    Energy Technology Data Exchange (ETDEWEB)

    Shimazaki, Y; Cordonnier, M M; Pratt, L H

    1983-01-01

    An enzyme-linked immunosorbent assay (ELISA), which uses both rabbit polyclonal and mouse monoclonal antibodies to phytochrome, has been adapted for quantitation of phytochrome in crude plant extracts. The assay has a detection limit of about 100 pg phytochrome and can be completed within 10 h. Quantitation of phytochrome in crude extracts of etiolated oat seedlings by ELISA gave values that agreed well with those obtained by spectrophotometric assay. When etiolated oat seedlings were irradiated continuously for 24 h, the amount of phytochrome detected by ELISA and by spectrophotometric assay decreased by more than 1000-fold and about 100-fold, respectively. This discrepancy indicates that phytochrome in light-treated plants may be antigenically distinct from that found in fully etiolated plants. When these light-grown oat seedlings were kept in darkness for 48 h, phytochrome content detected by ELISA increased by 50-fold in crude extracts of green oat shoots, but only about 12-fold in extracts of herbicide-treated oat shoots. Phytochrome reaccumulation in green oat shoots was initially more rapid in the more mature cells of the primary leaf tip than near the basal part of the shoot. The inhibitory effect of Norflurazon on phytochrome accumulation was much more evident near the leaf tip than the shoot base. A 5-min red irradiation of oat seedlings at the end of a 48-h dark period resulted in a subsequent, massive decrease in phytochrome content in crude extracts from both green and Norflurazon-bleached oat shoots. These observations eliminate the possibility that substantial accumulation of chromophore-free phytochrome was being detected and indicate that Norflurazon has a substantial effect on phytochrome accumulation during a prolonged dark period. 25 references, 9 figures, 3 tables.

  15. Assessment of Dextran Antigenicity of Intravenous Iron Preparations with Enzyme-Linked Immunosorbent Assay (ELISA).

    Science.gov (United States)

    Neiser, Susann; Koskenkorva, Taija S; Schwarz, Katrin; Wilhelm, Maria; Burckhardt, Susanna

    2016-07-21

    Intravenous iron preparations are typically classified as non-dextran-based or dextran/dextran-based complexes. The carbohydrate shell for each of these preparations is unique and is key in determining the various physicochemical properties, the metabolic pathway, and the immunogenicity of the iron-carbohydrate complex. As intravenous dextran can cause severe, antibody-mediated dextran-induced anaphylactic reactions (DIAR), the purpose of this study was to explore the potential of various intravenous iron preparations, non-dextran-based or dextran/dextran-based, to induce these reactions. An IgG-isotype mouse monoclonal anti-dextran antibody (5E7H3) and an enzyme-linked immunosorbent assay (ELISA) were developed to investigate the dextran antigenicity of low molecular weight iron dextran, ferumoxytol, iron isomaltoside 1000, ferric gluconate, iron sucrose and ferric carboxymaltose, as well as isomaltoside 1000, the isolated carbohydrate component of iron isomaltoside 1000. Low molecular weight iron dextran, as well as dextran-based ferumoxytol and iron isomaltoside 1000, reacted with 5E7H3, whereas ferric carboxymaltose, iron sucrose, sodium ferric gluconate, and isolated isomaltoside 1000 did not. Consistent results were obtained with reverse single radial immunodiffusion assay. The results strongly support the hypothesis that, while the carbohydrate alone (isomaltoside 1000) does not form immune complexes with anti-dextran antibodies, iron isomaltoside 1000 complex reacts with anti-dextran antibodies by forming multivalent immune complexes. Moreover, non-dextran based preparations, such as iron sucrose and ferric carboxymaltose, do not react with anti-dextran antibodies. This assay allows to assess the theoretical possibility of a substance to induce antibody-mediated DIARs. Nevertheless, as this is only one possible mechanism that may cause a hypersensitivity reaction, a broader set of assays will be required to get an understanding of the mechanisms that may

  16. Quantification of methanogenic biomass by enzyme-linked immunosorbent assay and by analysis of specific methanogenic cofactors

    Energy Technology Data Exchange (ETDEWEB)

    Gorris, L G.M.; Kemp, H A; Archer, D B

    1987-01-01

    The reliability and accuracy with which enzyme-linked immunosorbent assay (ELISA) and an assay of methanogenic cofactors detect and quantify methanogenic species were investigated. Both assays required standardization with laboratory cultures of methanogenic bacteria and were applied to mixtures of pure cultures and samples from anaerobic digesters. ELISA was shown to be a simple method for detecting and quantifying individual methanogenic species. The range of species which can be assayed is limited by the range of antisera available but, potentially, ELISA can be applied to all methanogens. Although the cofactor assay is not species-specific it can distinguish hydrogenotrophic and acetotrophic methanogens and is quantitative.

  17. Single-dilution enzyme-linked immunosorbent assay for quantification of antigen-specific salmonid antibody

    Science.gov (United States)

    Alcorn, S.W.; Pascho, R.J.

    2000-01-01

    An enzyme-linked immunosorbent assay (ELISA) was developed on the basis of testing a single dilution of serum to quantify the level of antibody to the p57 protein of Renibaclerium salmoninarum in sockeye salmon (Oncorhynchus nerka). The levels of antibody were interpolated from a standard curve constructed by relating the optical densities (OD) produced by several dilutions of a high-titer rainbow trout (O. mykiss) antiserum to the p57 protein. The ELISA OD values produced by as many as 36 test sera on each microplate were compared with the standard curve to calculate the antigen-specific antibody activity. Repeated measurements of 36 samples on 3 microplates on each of 6 assay dates indicated that the mean intraassay coefficient of variation (CV) was 6.68% (range, 0-23%) and the mean interassay CV was 8.29% (range, 4-16%). The antibody levels determined for the serum sample from 24 sockeye salmon vaccinated with a recombinant p57 protein generally were correlated with the levels determined by endpoint titration (r2 = 0.936) and with results from another ELISA that was based on extrapolation of antibody levels from a standard curve (r2 = 0.956). The single-dilution antibody ELISA described here increases the number of samples that can be tested on each microplate compared with immunoassays based on analysis of several dilutions of each test serum. It includes controls for interassay standardization and can be used to test fish weighing <3 g.

  18. Enzyme-linked immunosorbent assays for detection of equine antibodies specific to Sarcocystis neurona surface antigens.

    Science.gov (United States)

    Hoane, Jessica S; Morrow, Jennifer K; Saville, William J; Dubey, J P; Granstrom, David E; Howe, Daniel K

    2005-09-01

    Sarcocystis neurona is the primary causative agent of equine protozoal myeloencephalitis (EPM), a common neurologic disease of horses in the Americas. We have developed a set of enzyme-linked immunosorbent assays (ELISAs) based on the four major surface antigens of S. neurona (SnSAGs) to analyze the equine antibody response to S. neurona. The SnSAG ELISAs were optimized and standardized with a sample set of 36 equine sera that had been characterized by Western blotting against total S. neurona parasite antigen, the current gold standard for S. neurona serology. The recombinant SnSAG2 (rSnSAG2) ELISA showed the highest sensitivity and specificity at 95.5% and 92.9%, respectively. In contrast, only 68.2% sensitivity and 71.4% specificity were achieved with the rSnSAG1 ELISA, indicating that this antigen may not be a reliable serological marker for analyzing antibodies against S. neurona in horses. Importantly, the ELISA antigens did not show cross-reactivity with antisera to Sarcocystis fayeri or Neospora hughesi, two other equine parasites. The accuracy and reliability exhibited by the SnSAG ELISAs suggest that these assays will be valuable tools for examining the equine immune response against S. neurona infection, which may help in understanding the pathobiology of this accidental parasite-host interaction. Moreover, with modification and further investigation, the SnSAG ELISAs have potential for use as immunodiagnostic tests to aid in the identification of horses affected by EPM.

  19. Enzyme-Linked Immunosorbent Assays for Detection of Equine Antibodies Specific to Sarcocystis neurona Surface Antigens†

    Science.gov (United States)

    Hoane, Jessica S.; Morrow, Jennifer K.; Saville, William J.; Dubey, J. P.; Granstrom, David E.; Howe, Daniel K.

    2005-01-01

    Sarcocystis neurona is the primary causative agent of equine protozoal myeloencephalitis (EPM), a common neurologic disease of horses in the Americas. We have developed a set of enzyme-linked immunosorbent assays (ELISAs) based on the four major surface antigens of S. neurona (SnSAGs) to analyze the equine antibody response to S. neurona. The SnSAG ELISAs were optimized and standardized with a sample set of 36 equine sera that had been characterized by Western blotting against total S. neurona parasite antigen, the current gold standard for S. neurona serology. The recombinant SnSAG2 (rSnSAG2) ELISA showed the highest sensitivity and specificity at 95.5% and 92.9%, respectively. In contrast, only 68.2% sensitivity and 71.4% specificity were achieved with the rSnSAG1 ELISA, indicating that this antigen may not be a reliable serological marker for analyzing antibodies against S. neurona in horses. Importantly, the ELISA antigens did not show cross-reactivity with antisera to Sarcocystis fayeri or Neospora hughesi, two other equine parasites. The accuracy and reliability exhibited by the SnSAG ELISAs suggest that these assays will be valuable tools for examining the equine immune response against S. neurona infection, which may help in understanding the pathobiology of this accidental parasite-host interaction. Moreover, with modification and further investigation, the SnSAG ELISAs have potential for use as immunodiagnostic tests to aid in the identification of horses affected by EPM. PMID:16148170

  20. Detection of copper ions using microcantilever immunosensors and enzyme-linked immunosorbent assay

    Energy Technology Data Exchange (ETDEWEB)

    Zhao Hongwei [College of Agronomy and Biotechnology, China Agricultural University, Beijing 100193 (China); Xue Changguo [Key Laboratory of Mechanical Behavior and Design of Material of Chinese Academy of Sciences, University of Science and Technology of China, Hefei 230027 (China); Nan Tiegui; Tan Guiyu; Li Zhaohu [College of Agronomy and Biotechnology, China Agricultural University, Beijing 100193 (China); Li, Qing X. [Department of Molecular Biosciences and Bioengineering, University of Hawaii at Manoa, Honolulu, HI 96822 (United States); Zhang Qingchuan, E-mail: zhangqc@ustc.edu.cn [Key Laboratory of Mechanical Behavior and Design of Material of Chinese Academy of Sciences, University of Science and Technology of China, Hefei 230027 (China); Wang Baomin, E-mail: wbaomin@263.com [College of Agronomy and Biotechnology, China Agricultural University, Beijing 100193 (China)

    2010-08-31

    A sensitive and specific monoclonal antibody (designated as mAb6A9) recognizing a Cu(II)-ethylenediamine-N,N,N',N'-tetraacetic acid (EDTA) complex but not metal-free EDTA was obtained by using an 1-(4-aminobenzyl)-EDTA-Cu(II) complex covalently coupled to a carrier protein as an immunogen to immunize the Balb/c mice. A mAb6A9-modified microcantilever sensor (MCS) was developed. A bending response was found to occur at or below 1 ng mL{sup -1} of Cu(II)-EDTA complex. An indirect competitive enzyme-linked immunosorbent assay (icELISA) was developed with mAb6A9. The icELISA had a half maximum inhibition concentration and working range of approximately 1.8 and 0.2-17 ng mL{sup -1}, respectively. The icELISA showed cross-reactivity of 18.8%, 1.1% and less than 1% with bivalent cobalt, mercury and other metals, respectively. The icELISA and functionalized MCSs were utilized to analyze the content of copper in spiked tap water samples. The assay conditions were optimized. The results of icELISA and MCS correlated well with those obtained by graphite furnace atomic absorption spectrometry.

  1. Biotin-Streptavidin Competition Mediates Sensitive Detection of Biomolecules in Enzyme Linked Immunosorbent Assay.

    Science.gov (United States)

    Lakshmipriya, Thangavel; Gopinath, Subash C B; Tang, Thean-Hock

    2016-01-01

    Enzyme Linked Immunosorbent Assay (ELISA) is the gold standard assay for detecting and identifying biomolecules using antibodies as the probe. Improving ELISA is crucial for detecting disease-causing agents and facilitating diagnosis at the early stages of disease. Biotinylated antibody and streptavidin-conjugated horse radish peroxide (streptavidin-HRP) often are used with ELISA to enhance the detection of various kinds of targets. In the present study, we used a competition-based strategy in which we pre-mixed free biotin with streptavidin-HRP to generate high-performance system, as free biotin occupies some of the biotin binding sites on streptavidin, thereby providing more chances for streptavidin-HRP to bind with biotinylated antibody. ESAT-6, which is a protein secreted early during tuberculosis infection, was used as the model target. We found that 8 fM of free biotin mixed with streptavidin-HRP anchored the higher detection level of ESAT-6 by four-fold compared with detection without free biotin (only streptavidin-HRP), and the limit of detection of the new method was 250 pM. These results suggest that biotin-streptavidin competition can be used to improve the diagnosis of analytes in other types of sensors.

  2. Enzyme-linked immunosorbent assay for the quantitative/qualitative analysis of plant secondary metabolites.

    Science.gov (United States)

    Sakamoto, Seiichi; Putalun, Waraporn; Vimolmangkang, Sornkanok; Phoolcharoen, Waranyoo; Shoyama, Yukihiro; Tanaka, Hiroyuki; Morimoto, Satoshi

    2018-01-01

    Immunoassays are antibody-based analytical methods for quantitative/qualitative analysis. Since the principle of immunoassays is based on specific antigen-antibody reaction, the assays have been utilized worldwide for diagnosis, pharmacokinetic studies by drug monitoring, and the quality control of commercially available products. Berson and Yalow were the first to develop an immunoassay, known as radioimmunoassay (RIA), for detecting endogenous plasma insulin [1], a development for which Yalow was awarded the Nobel Prize in Physiology or Medicine in 1977. Even today, after half a century, immunoassays are widely utilized with some modifications from the originally proposed system, e.g., radioisotopes have been replaced with enzymes because of safety concerns regarding the use of radioactivity, which is referred to as enzyme immunoassay/enzyme-linked immunosorbent assay (ELISA). In addition, progress has been made in ELISA with the recent advances in recombinant DNA technology, leading to increase in the range of antibodies, probes, and even systems. This review article describes ELISA and its applications for the detection of plant secondary metabolites.

  3. Detection of copper ions using microcantilever immunosensors and enzyme-linked immunosorbent assay

    International Nuclear Information System (INIS)

    Zhao Hongwei; Xue Changguo; Nan Tiegui; Tan Guiyu; Li Zhaohu; Li, Qing X.; Zhang Qingchuan; Wang Baomin

    2010-01-01

    A sensitive and specific monoclonal antibody (designated as mAb6A9) recognizing a Cu(II)-ethylenediamine-N,N,N',N'-tetraacetic acid (EDTA) complex but not metal-free EDTA was obtained by using an 1-(4-aminobenzyl)-EDTA-Cu(II) complex covalently coupled to a carrier protein as an immunogen to immunize the Balb/c mice. A mAb6A9-modified microcantilever sensor (MCS) was developed. A bending response was found to occur at or below 1 ng mL -1 of Cu(II)-EDTA complex. An indirect competitive enzyme-linked immunosorbent assay (icELISA) was developed with mAb6A9. The icELISA had a half maximum inhibition concentration and working range of approximately 1.8 and 0.2-17 ng mL -1 , respectively. The icELISA showed cross-reactivity of 18.8%, 1.1% and less than 1% with bivalent cobalt, mercury and other metals, respectively. The icELISA and functionalized MCSs were utilized to analyze the content of copper in spiked tap water samples. The assay conditions were optimized. The results of icELISA and MCS correlated well with those obtained by graphite furnace atomic absorption spectrometry.

  4. Reliability of soluble IL-2 receptor measurements obtained with enzyme-linked immunosorbent assay

    International Nuclear Information System (INIS)

    Akiyama, Mitoshi; Takaishi, Masatoshi; Murakami, Yoshie; Ueda, Ryuzo; Yamakido, Michio; Tsubokura, Tokuo.

    1989-09-01

    Using an enzyme-linked immunosorbent assay (ELISA), human soluble interleukin-2 receptors (IL-2R) were measured in the serum of patients with various autoimmune system diseases. To study the sensitivity and specificity of the assay, soluble IL-2Rs were measured in the culture supernatants and in the cell extracts of peripheral blood mononuclear cells activated with phytohemagglutinin (PHA), purified protein derivative of tuberculin, and allogeneic lymphocytes, as well as in the serum of patients with various collagen diseases. The results correlated well with reports from other laboratories. For example, when stimulated by PHA, the greatest amount of soluble IL-2Rs was produced at the fastest rate. In addition, soluble IL-2R levels in the serum of collagen disease patients were significantly higher than those in healthy persons, who themselves exhibited low levels of detectable soluble IL-2Rs. It is hoped that reliable ELISA measurements of soluble IL-2Rs in the serum of atomic bomb survivors will assist in the interpretation of data collected during the work described in RP 2-87, a study of autoimmunity and autoimmune diseases in the Adult Health Study. (author)

  5. Development and validation of an enzyme-linked immunosorbent assay for the quantification of trastuzumab in human serum and plasma

    NARCIS (Netherlands)

    Damen, Carola W. N.; de Groot, Els R.; Heij, Marianne; Boss, David S.; Schellens, Jan H. M.; Rosing, Hilde; Beijnen, Jos H.; Aarden, Lucien A.

    2009-01-01

    Trastuzumab, a humanized monoclonal antibody, is used for the treatment of breast cancer patients who overexpress the HER2 receptor. To optimize therapy, pharmacokinetic studies are necessary. The aim of this study was to develop an enzyme-linked immunosorbent assay (ELISA) for trastuzumab to

  6. A sensitive monoclonal antibody-based enzyme-linked immunosorbent assay for chlorpyrifos residue determination in Chinese agricultural smaples

    Science.gov (United States)

    A monoclonal antibody-based competitive antibody-coated enzyme-linked immunosorbent assay (ELISA) was developed and optimized for determining chlorpyrifos residue in agricultural products. The IC50 and IC10 of this ELISA were 3.3 ng/mL and 0.1 ng/mL respectively. The average recoveries recovery rate...

  7. Immunoglobulin G1 enzyme-linked Immunosorbent assay for diagnosis of Johne's disease in red deer (Cervus elaphus)

    NARCIS (Netherlands)

    Griffin, J.F.T.; Spittle, E.; Rodgers, C.R.; Liggett, S.; Cooper, M.; Bakker, D.; Bannantine, J.P.

    2005-01-01

    This study was designed to develop a customized enzyme-linked immunosorbent assay (ELISA) for the serodiagnosis of Johne's disease (JD) in farmed deer. Two antigens were selected on the basis of their superior diagnostic readouts: denatured purified protein derivative (PPDj) and undenatured

  8. EVALUATION OF AN ENZYME-LINKED IMMUNOSORBENT ASSAY FOR BIOLOGICAL MONITORING OF 3-PHENOXYBENZOIC ACID IN URINE

    Science.gov (United States)

    Abstract describes the development of an enzyme-linked immunosorbent assay (ELISA) method for monitoring 2,4-dichlorophenoxyacetic acid (2,4-D exposures). The ELISA is compared with a gas chromatograhy/mass spectrometry procedure. ELISA method development steps and comparative ...

  9. Immunological Tools: Engaging Students in the Use and Analysis of Flow Cytometry and Enzyme-linked Immunosorbent Assay (ELISA)

    Science.gov (United States)

    Ott, Laura E.; Carson, Susan

    2014-01-01

    Flow cytometry and enzyme-linked immunosorbent assay (ELISA) are commonly used techniques associated with clinical and research applications within the immunology and medical fields. The use of these techniques is becoming increasingly valuable in many life science and engineering disciplines as well. Herein, we report the development and…

  10. Validation of 2 commercial Neospora caninum antibody enzyme linked immunosorbent assays

    Science.gov (United States)

    Wu, John T.Y.; Dreger, Sally; Chow, Eva Y.W.; Bowlby, Evelyn E.

    2002-01-01

    Abstract This is a validation study of 2 commercially available enzyme linked immunosorbent assays (ELISA) for the detection of antibodies against Neospora caninum in bovine serum. The results of the reference sera (n = 30) and field sera from an infected beef herd (n = 150) were tested by both ELISAs and the results were compared statistically. When the immunoblotting results of the reference bovine sera were compared to the ELISA results, the same identity score (96.67%) and kappa values (K) (0.93) were obtained for both ELISAs. The sensitivity and specificity values for the IDEXX test were 100% and 93.33% respectively. For the Biovet test 93.33% and 100% were obtained. The corresponding positive (PV+) and negative predictive (PV−) values for the 2 assays were 93.75% and 100% (IDEXX), and 100% and 93.75% (Biovet). In the 2nd study, competitive inhibition ELISA (c-ELISA) results on bovine sera from an infected herd were compared to the 2 sets of ELISA results. The identity scores of the 2 ELISAs were 98% (IDEXX) and 97.33% (Biovet). The K values calculated were 0.96 (IDEXX) and 0.95 (Biovet). For the IDEXX test the sensitivity and specificity were 97.56% and 98.53%, whereas for the Biovet assay 95.12% and 100% were recorded, respectively. The corresponding PV+ and PV− values were 98.77% and 97.1% (IDEXX), and 100% and 94.44% (Biovet). Our validation results showed that the 2 ELISAs worked equally well and there was no statistically significant difference between the performance of the 2 tests. Both tests showed high reproducibility, repeatability and substantial agreement with results from 2 other laboratories. A quality assurance based on the requirement of the ISO/IEC 17025 standards has been adopted throughout this project for test validation procedures. PMID:12418782

  11. Development of Two Antibody Detection Enzyme-Linked Immunosorbent Assays for Serodiagnosis of Human Chronic Fascioliasis

    Science.gov (United States)

    Cabán-Hernández, Kimberly; Gaudier, José F.; Ruiz-Jiménez, Caleb

    2014-01-01

    Coprological examination based on egg detection in stool samples is currently used as the gold standard for the diagnosis of human fascioliasis. However, this method is not effective during the acute phase of the disease and has poor sensitivity during the chronic phase. Serodiagnosis has become an excellent alternative to coprological examination in efforts to combat the effects of fascioliasis on human and animal health. Two novel recombinant Fasciola hepatica proteins, i.e., a ferritin (FhFtn-1) and a tegument-associated protein (FhTP16.5), were used as antigens to develop in-house enzyme-linked immunosorbent assay (ELISA) methods. The assays were optimized and validated using 152 serum samples from humans with a known infection status, including healthy subjects, patients with chronic fascioliasis, and patients with other parasitic diseases. The FhFtn-1 ELISA was shown to be 96.6% sensitive and 95.7% specific; the respective parameters for the FhTP16.5 ELISA were 91.4% and 92.4%. The performances of the FhFtn-1 and FhTP16.5 ELISAs were compared with that of an available commercial test (the DRG test) using a subset of serum samples. Our in-house tests were slightly more sensitive than the DRG test in detecting antibodies against F. hepatica, but the differences were not statistically significant. In conclusion, the present study provides evidence for the potential of the FhFtn-1 and FhTP16.5 ELISAs as diagnostic tools for human fascioliasis, as might be implemented in conjunction with standard assays for large-scale screenings in areas where the disease is endemic and for the detection of occasional cases in clinical laboratories. PMID:24353000

  12. Development of two antibody detection enzyme-linked immunosorbent assays for serodiagnosis of human chronic fascioliasis.

    Science.gov (United States)

    Cabán-Hernández, Kimberly; Gaudier, José F; Ruiz-Jiménez, Caleb; Espino, Ana M

    2014-03-01

    Coprological examination based on egg detection in stool samples is currently used as the gold standard for the diagnosis of human fascioliasis. However, this method is not effective during the acute phase of the disease and has poor sensitivity during the chronic phase. Serodiagnosis has become an excellent alternative to coprological examination in efforts to combat the effects of fascioliasis on human and animal health. Two novel recombinant Fasciola hepatica proteins, i.e., a ferritin (FhFtn-1) and a tegument-associated protein (FhTP16.5), were used as antigens to develop in-house enzyme-linked immunosorbent assay (ELISA) methods. The assays were optimized and validated using 152 serum samples from humans with a known infection status, including healthy subjects, patients with chronic fascioliasis, and patients with other parasitic diseases. The FhFtn-1 ELISA was shown to be 96.6% sensitive and 95.7% specific; the respective parameters for the FhTP16.5 ELISA were 91.4% and 92.4%. The performances of the FhFtn-1 and FhTP16.5 ELISAs were compared with that of an available commercial test (the DRG test) using a subset of serum samples. Our in-house tests were slightly more sensitive than the DRG test in detecting antibodies against F. hepatica, but the differences were not statistically significant. In conclusion, the present study provides evidence for the potential of the FhFtn-1 and FhTP16.5 ELISAs as diagnostic tools for human fascioliasis, as might be implemented in conjunction with standard assays for large-scale screenings in areas where the disease is endemic and for the detection of occasional cases in clinical laboratories.

  13. Enzyme-linked immunosorbent assay (ELISA) for the anthropogenic marker isolithocholic acid in water.

    Science.gov (United States)

    Baldofski, Stefanie; Hoffmann, Holger; Lehmann, Andreas; Breitfeld, Stefan; Garbe, Leif-Alexander; Schneider, Rudolf J

    2016-11-01

    Bile acids are promising chemical markers to assess the pollution of water samples with fecal material. This study describes the optimization and validation of a direct competitive enzyme-linked immunosorbent assay for the bile acid isolithocholic acid (ILA). The quantification range of the optimized assay was between 0.09 and 15 μg/L. The assay was applied to environmental water samples. Most studies until now were focused on bile acid fractions in the particulate phase of water samples. In order to avoid tedious sample preparation, we undertook to evaluate the dynamics and significance of ILA levels in the aqueous phase. Very low concentrations in tap and surface water samples made a pre-concentration step necessary for this matrix as well as for wastewater treatment plant (WWTP) effluent. Mean recoveries for spiked water samples were between 97% and 109% for tap water and WWTP influent samples and between 102% and 136% for WWTP effluent samples. 90th percentiles of intra-plate and inter-plate coefficients of variation were below 10% for influents and below 20% for effluents and surface water. ILA concentrations were quantified in the range of 33-72 μg/L in influent, 21-49 ng/L in effluent and 18-48 ng/L in surface water samples. During wastewater treatment the ILA levels were reduced by more than 99%. ILA concentrations of influents determined by ELISA and LC-MS/MS were in good agreement. However, findings in LC-ELISA experiments suggest that the true ILA levels in concentrated samples are lower due to interfering effects of matrix compounds and/or cross-reactants. Yet, the ELISA will be a valuable tool for the performance check and comparison of WWTPs and the localization of fecal matter input into surface waters. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. Immunodiagnosis of Human Fascioliasis by an Enzyme-Linked Immunosorbent Assay (ELISA) and a Micro-ELISA

    OpenAIRE

    Carnevale, Silvana; Rodríguez, Mónica I.; Santillán, Graciela; Labbé, Jorge H.; Cabrera, Marta G.; Bellegarde, Enrique J.; Velásquez, Jorge N.; Trgovcic, Jorge E.; Guarnera, Eduardo A.

    2001-01-01

    Enzyme-linked immunosorbent assay (ELISA) and micro-ELISA were evaluated for their ability to detect anti-Fasciola hepatica antibodies in humans by using excretory-secretory antigen. The sensitivity of each method was 100%, but the specificity was 100% for ELISA and 97% for micro-ELISA. The micro-ELISA could be used as a screening assay and ELISA could be used as a confirmatory method for the serodiagnosis of human fascioliasis.

  15. Sandwich-dot enzyme-linked immunosorbent assay for the detection of canine distemper virus

    Science.gov (United States)

    Li, Zhi; Zhang, Yanlong; Wang, Huiguo; Jin, Jinhua; Li, Wenzhe

    2013-01-01

    A sandwich-dot enzyme-linked immunosorbent assay (dot ELISA) was developed for the detection of canine distemper virus (CDV). In 56 dogs suspected to have CD the rates of detection of CDV antigen in samples of blood lymphocytes and palpebral conjunctiva by dot ELISA and ELISA were, respectively, 91% (49/54) and 81% (44/54) for the lymphocyte samples and 88% (28/32) and 75% (24/32) for the conjunctival samples. The CDV detection limits were 10 ng/50 μL for dot ELISA and 40 ng/50 μL for ELISA. The reliability of dot ELISA relative to electron microscopy was 96% with 22 samples: all 21 samples in which CDV particles were observed by electron microscopy yielded positive results with dot ELISA; the single sample in which particles were not observed yielded false-positive results with dot ELISA. The results indicate that the dot ELISA developed can serve as a reliable rapid diagnostic test in suspected cases of CD and also be useful for epidemiologic surveillance of the disease. PMID:24124274

  16. Magnetic nanoparticle based purification and enzyme-linked immunosorbent assay using monoclonal antibody against enrofloxacin

    Science.gov (United States)

    Kim, Nam-Gun; Kim, Myeong-Ae; Park, Young-Il; Jung, Tae-Sung; Son, Seong-Wan; So, ByungJae

    2015-01-01

    Monoclonal anti-enrofloxacin antibody was prepared for a direct competitive enzyme-linked immunosorbent assay (ELISA) and purification system using monoclonal antibody (mAb) coupled magnetic nanoparticles (MNPs). The IC50 values of the developed mAb for enrofloxacin (ENR), ciprofloxacin, difloxacin, sarafloxacin, pefloxacin, and norfloxacin were 5.0, 8.3, 9.7, 21.7, 36.0, and 63.7 ng/mL, respectively. The lowest detectable level of ENR was 0.7 ng/mL in the prepared ELISA system. To validate the developed ELISA in the food matrix, known amounts of ENR were spiked in meat and egg samples at 10, 20 and 30 ng/mL. Recoveries for ENR ranged from 72.9 to 113.16% with a coefficient of variation (CV) of 2.42 to 10.11%. The applicability of the mAb-MNP system was verified by testing the recoveries for ENR residue in three different matrices. Recoveries for ENR ranged from 75.16 to 86.36%, while the CV ranged from 5.08 to 11.53%. Overall, ENR-specific monoclonal antibody was prepared and developed for use in competitive to ELISAs for the detection of ENR in animal meat samples. Furthermore, we suggest that a purification system for ENR using mAb-coupled MNPs could be useful for determination of ENR residue in food. PMID:26040610

  17. Enzyme-linked immunosorbent assay and radioimmunoassay of serum pepsinogen A

    International Nuclear Information System (INIS)

    Pals, Gerard; Meuwissen, S.G.M.; Frants, R.R.; Kostense, P.J.; Eriksson, A.W.; Raesaenen, Vesa

    1987-01-01

    The determination of serum pepsinogen A (=pepsinogen I) levels is of clinical importance in the study of duodenal ulcer, atrophic gastritis and gastric cancer. In the present study two different quantitative immunological techniques for serum pepsinogen A were compared: a radioimmunoassay (RIA) (Helsinki) and an enzyme-linked immunosorbent assay (ELISA) (Amsterdam). Serum samples of 177 subjects with various gastric diseases were tested in a double blind study. The correlation was excellent (r=0.954 in the range 0-760 μg/l and r=0.971 in the range 0-100 μg/l). The functional relationship between ELISA (x) and RIA (y), determined by weighted model II regression, was y=1.12x-0.54. Initially the use of goat anti-PGA in the ELISA resulted in falsely high values in about 10% of the individuals. This was caused by circulating antibodies cross-reacting with goat IgG. This artefact was eliminated by pre-incubation of all samples with non-immune goat serum. (author)

  18. Enzyme-linked immunosorbent assay for ultratrace determination of antibiotics in aqueous samples.

    Science.gov (United States)

    Kumar, Kuldip; Thompson, Anita; Singh, Ashok K; Chander, Yogesh; Gupta, Satish C

    2004-01-01

    Two commercially available enzyme-linked immunosorbent assay (ELISA) kits that are commonly used for tylosin or tetracycline residues in meat and milk were adapted for ultratrace analysis of these antibiotics in surface and ground waters. These two antibiotics are commonly fed to swine, turkeys, and cattle at subtherapeutic doses for growth promotion purposes. Both ELISA techniques were found to be highly sensitive and selective for the respective antibiotics with detection limits of 0.10 and 0.05 microg L(-1) for tylosin and tetracycline, respectively. The recovery of both tylosin and tetracycline from spiked samples of lake waters, runoff samples, soil saturation extracts, and nanopure water was close to 100%. Tetracycline ELISA was highly specific for tetracycline and chlortetracycline but not for other forms of tetracycline (oxytetracycline, demeclocycline, and doxycycline). Analysis of a few liquid swine manure samples by liquid chromatography-mass spectrometry (LC-MS) showed lower concentrations for chlortetracycline as compared with concentrations obtained using ELISA. However, the concentrations of tylosin from ELISA were comparable with that of LC-MS. The lower concentrations of chlortetracycline obtained by LC-MS in manure samples indicate the presence of other similar or transformed compounds that were detected by ELISA but not determined by LC-MS. These results indicate that both ELISA kits can be useful tools for low-cost screening of tylosin, tetracycline, and chlortetracycline in environmental waters. Furthermore, both ELISA procedures are rapid, portable, and easily adaptable for testing of multiple samples simultaneously.

  19. Antibody screening by enzyme-linked immunosorbent assay using pooled soluble HLA in renal transplant candidates.

    Science.gov (United States)

    Zaer, F; Metz, S; Scornik, J C

    1997-01-15

    The enzyme-linked immunosorbent assay (ELISA) using HLA class I molecules purified from pooled platelets has the potential to detect HLA antibodies with increased efficiency without sacrificing sensitivity or specificity. This test, which was originally developed in our institution, has been independently validated by recent studies and is now commercially available. We now present evidence of its usefulness as a routine HLA antibody screening test for renal transplant patients. A total of 515 patients were tested monthly by ELISA (13.9 tests/patient) and by antiglobulin-enhanced panel reactivity (6.3 tests/patient). In patients found to be unsensitized, the incidence of false-positive results was less for ELISA than for the panel studies. In patients who were highly sensitized, both tests performed equally well, whereas discordant results were registered mainly in cases of mild sensitization. Because 66% of our patients were not sensitized, the ELISA was effective in reducing the number of more involved tests aimed at characterizing the antibodies. These results provide a foundation to use the pooled platelet HLA ELISA on a routine basis for HLA antibody screening.

  20. Enzyme-linked immunosorbent assay and radioimmunoassay of serum pepsinogen A

    Energy Technology Data Exchange (ETDEWEB)

    Pals, G; Meuwissen, S G.M.; Frants, R R; Kostense, P J; Eriksson, A W; Raesaenen, V

    1987-02-01

    The determination of serum pepsinogen A (=pepsinogen I) levels is of clinical importance in the study of duodenal ulcer, atrophic gastritis and gastric cancer. In the present study two different quantitative immunological techniques for serum pepsinogen A were compared: a radioimmunoassay (RIA) (Helsinki) and an enzyme-linked immunosorbent assay (ELISA) (Amsterdam). Serum samples of 177 subjects with various gastric diseases were tested in a double blind study. The correlation was excellent (r=0.954 in the range 0-760 ..mu..g/l and r=0.971 in the range 0-100 ..mu..g/l). The functional relationship between ELISA (x) and RIA (y), determined by weighted model II regression, was y=1.12x-0.54. Initially the use of goat anti-PGA in the ELISA resulted in falsely high values in about 10% of the individuals. This was caused by circulating antibodies cross-reacting with goat IgG. This artefact was eliminated by pre-incubation of all samples with non-immune goat serum.

  1. Evaluation of electrochemiluminescene immunoassay and enzyme-linked immunosorbent assay for serum HBsAb detection

    International Nuclear Information System (INIS)

    Ma Caiyun; Jiang Li; Ge Gaoxia; Zhang Xiaojie

    2005-01-01

    Electrochemiluminescene immunoassay (ECLIA) and enzyme-linked immunosorbent (ELISA) were used to detect the different concentrations of serum HBsAb, in order to compare the results of ECLIA and ELISA. The result showed that intra-assay coefficient of variation of ECLIA was about 0.95% for high value, 1.13% for mean values and 2.63% for low value, while that of ELISA was about 5.76%, 12.8% and 15.9%, respectively. The interassay coefficient of ECLIA was about 4.03% for high values, 4.93% for mean values and 7.34% for low values, while that of ELISA was about 10.1%, 19.6% and 25.2%, respectively. The analytical sensitivity of ECLIA was about 4.0IU/L, while that of ELISA is about 19.0IU/L. Only in 3 samples, the results measured by ECLIA and ELISA were different (ECLIA: positive; ELISA: negative) among 165 samples. It is concluded that the met hod of ECLIA is more efficient than ELISA for detection of HBsAb in serum. (authors)

  2. DEVELOPMENT OF ENZYME-LINKAGE IMMUNOSORBENT ASSAY AGAINST TYPE B OF CLOSTRIDIUM BOTULINUM: A PRELIMINARY STUDY

    Directory of Open Access Journals (Sweden)

    S. N. Depamede

    2011-12-01

    Full Text Available Clostridium botulinum neurotoxin (BoNTs is one of the causes of economic loss in the livestock industry. This economic loss would be as a direct result when animals poisoned by BoNTs or indirectly when the livestock products are contaminated by BoNTs, which end up with the products are banned by authority. Therefore a routine surveillance of BoNTs in the farm and in livestock product processing industry is urgently needed. One of the most relatively quick and accurate methods to perform a routine detection of the presence of BoNTs is enzyme-linkage immunosorbant assay (ELISA. In this article we describe the results of the development of ELISA, using polyclonal antibodies against BoNTs-B produced locally. Antibodies were generated from six Balb/c mice with standard immunological methods. Mice were immunized three times for a period of 8 weeks with a commercial type B Clostridium botulinum toxoid at a dose of 100 ng per mouse per injection. The resulting antibody was purified by a combination of ammonium sulfate precipitation 50% (w/v technique and a protein A column method. The results of this preliminary study indicated that the developed ELISA method capable of detecting type B Clostridium botulinum toxin up to 1.0 ng/ml.

  3. A sensitive enzyme-linked immunosorbent assay for the determination of fish protein in processed foods.

    Science.gov (United States)

    Shibahara, Yusuke; Uesaka, Yoshihiko; Wang, Jun; Yamada, Shoichi; Shiomi, Kazuo

    2013-01-15

    Fish is one of the most common causes of food allergy and its major allergen is parvalbumin, a 12 kDa muscular protein. In this study, a sandwich enzyme-linked immunosorbent assay (ELISA) for the determination of fish protein in processed foods was developed using a polyclonal antibody raised against Pacific mackerel parvalbumin. The developed sandwich ELISA showed 22.6-99.0% reactivity (based on the reactivity to Pacific mackerel parvalbumin) to parvalbumins from various species of fish. The limits of detection and quantitation were estimated to be 0.23 and 0.70 μg protein per g of food, respectively. When the sandwich ELISA was subjected to inter-laboratory validation, spiked fish protein was recovered from five model processed foods in the range of 69.4-84.8% and the repeatability and reproducibility relative standard deviations were satisfactorily low (≤ 10.5%). Thus, the sandwich ELISA was judged to be a useful tool to determine fish protein in processed foods. Copyright © 2012 Elsevier Ltd. All rights reserved.

  4. High sensitivity, high surface area Enzyme-linked Immunosorbent Assay (ELISA).

    Science.gov (United States)

    Singh, Harpal; Morita, Takahiro; Suzuki, Yuma; Shimojima, Masayuki; Le Van, An; Sugamata, Masami; Yang, Ming

    2015-01-01

    Enzyme-linked immunosorbent assays (ELISA) are considered the gold standard in the demonstration of various immunological reactions with an application in the detection of infectious diseases such as during outbreaks or in patient care. This study aimed to produce an ELISA-based diagnostic with an increased sensitivity of detection compared to the standard 96-well method in the immunologic diagnosis of infectious diseases. A '3DStack' was developed using readily available, low cost fabrication technologies namely nanoimprinting and press stamping with an increased surface area of 4 to 6 times more compared to 96-well plates. This was achieved by stacking multiple nanoimprinted polymer sheets. The flow of analytes between the sheets was enhanced by rotating the 3DStack and confirmed by Finite-Element (FE) simulation. An Immunoglobulin G (IgG) ELISA for the detection of antibodies in human serum raised against Rubella virus was performed for validation. An improved sensitivity of up to 1.9 folds higher was observed using the 3DStack compared to the standard method. The increased surface area of the 3DStack developed using nanoimprinting and press stamping technologies, and the flow pattern between sheets generated by rotating the 3DStack were potential contributors to a more sensitive ELISA-based diagnostic device.

  5. Detection of tetracosactide in plasma by enzyme-linked immunosorbent assay (ELISA).

    Science.gov (United States)

    Martin, Laurent; Chaabo, Ayman; Lasne, Françoise

    2015-06-01

    As a synthetic analogue of adrenocorticotropic hormone (ACTH), tetracosactide is prohibited in sport by the World Anti-Doping Agency (WADA). An enzyme-linked immunosorbent assay (ELISA) method is proposed for detection of this drug in plasma. Since its structure corresponds to the 24 N-terminal of the 39 amino acids of the natural endogenous peptide ACTH, tetracosactide can be detected with a commercial ELISA kit for ACTH that uses antibodies, the epitopes of which are located in the 1-24 part of ACTH. However, an essential condition for detection specificity is the preliminary total clearance of endogenous ACTH in the plasma samples. This is achieved by a preparative step based on cation-exchange chromatography before ELISA. The method is specific and sensitive (LOD: 30 pg/mL) and may be used as a screening analysis in anti-doping control. The pre-analytical conditions are shown to be of the upmost importance and recommendations for blood collection (EDTA tubes), sample transport (4 °C) and plasma sample storage (-20 °C) are presented. Copyright © 2014 John Wiley & Sons, Ltd.

  6. Development of enzyme-linked immunosorbent assay for detecting Ornithobacterium rhinotracheale (ORT infection in chicken

    Directory of Open Access Journals (Sweden)

    Adin Priadi

    2006-10-01

    Full Text Available Ornithobacterium rhinotracheale (ORT has been recognized in chicken in Indonesia and incriminated as a possible additional causative agent in respiratory disease complex. An enzyme-linked immunosorbent assay (ELISA has been developed for the seroepidemiological study of ORT infection in chickens. Ten weeks old chickens are injected with 0.5 ml of killed O. rhinotracheale emulsified in Freund's complete adjuvant at a concentration of 109 CFU/ml. Hyperimmune sera and non-reactive control sera were used to standardized the ELISA for ORT infection. Optimum condition for the ORT ELISA was antigen dilution 1/800, serum dilution 1/100 and 1/4000 conjugate dilution. Optical density cut-off point was determined by using 31 serum samples from 2 broiler farms. Cut-off for negative serum was 0.27 (mean + 3 standard deviation. With these optima, 187 chicken sera from broiler, layer and broiler breeder farms were collected and screened. Seroconvertions were detected from broiler and layer farms in Magelang district, Central Java (Bojong I, Paremono, Bojong II, Keblukan and a broiler breeder farm in West Java. The seraconvertion were 0, 10, 94, 88 and 100 percents respectively. These figures show that the prevalence of O. rhinotracheale infection in chicken in layer and breeder farms were very high.

  7. Detection of Plasmodium Aldolase Using a Smartphone and Microfluidic Enzyme Linked Immunosorbent Assay

    Directory of Open Access Journals (Sweden)

    Nikhil S. Gopal

    2017-01-01

    Full Text Available Background. Malaria control efforts are limited in rural areas. A low-cost system to monitor response without the use of electricity is needed. Plasmodium aldolase is a malaria biomarker measured using enzyme linked immunosorbent assay (ELISA techniques. A three-part system using ELISA was developed consisting of a microfluidic chip, hand crank centrifuge, and a smartphone. Methods. A circular microfluidic chip was fabricated using clear acrylic and a CO2 laser. A series of passive valves released reagents at precise times based upon centrifugal force. Color change was measured via smartphone camera using an application programmed in Java. The microchip was compared to a standard 96-well sandwich ELISA. Results. Results from standard ELISA were compared to microchip at varying concentrations (1–10 ng/mL. Over 15 different microfluidic patterns were tested, and a final prototype of the chip was created. The prototype microchip was compared to standard sandwich ELISA (n=20 using samples of recombinant aldolase. Color readings of standard ELISA and microfluidic microchip showed similar results. Conclusion. A low-cost microfluidic system could detect and follow therapeutic outcomes in rural areas and identify resistant strains.

  8. Direct immunofluorescence and enzyme-linked immunosorbent assays for evaluating chlorinated hydrocarbon degrading bacteria

    Energy Technology Data Exchange (ETDEWEB)

    Brigmon, R.L.; Franck, M.M.; Brey, J.; Fliermans, C.B. [Westinghouse Savannah River, Aiken, SC (United States). Environmental Biotechnology Section; Scott, D.; Lanclos, K. [Medical Coll. of Georgia, Augusta, GA (United States)

    1997-06-01

    Immunological procedures were developed to enumerate chlorinated hydrocarbon degrading bacteria. Polyclonal antibodies (Pabs) were produced by immunizing New Zealand white rabbits against 18 contaminant-degrading bacteria. These included methanotrophic and chlorobenzene (CB) degrading species. An enzyme-linked immunosorbent assay (ELISA) was used to test for specificity and sensitivity of the Pabs. Direct fluorescent antibodies (DFAs) were developed with these Pabs against select methanotrophic bacteria isolated from a trichloroethylene (TCE) contaminated landfill at the Savannah River Site (SRS) and cultures from the American Type Culture Collection (ATCC). Analysis of cross reactivity testing data showed some of the Pabs to be group specific while others were species specific. The threshold of sensitivity for the ELISA is 105 bacteria cells/ml. The DFA can detect as few as one bacterium per ml after concentration. Results from the DFA and ELISA techniques for enumeration of methanotrophic bacteria in groundwater were higher but not significantly different (P < 0.05) compared to indirect microbiological techniques such as MPN. These methods provide useful information on in situ community structure and function for bioremediation applications within 1--4 hours of sampling.

  9. Carbon dots based immunosorbent assay for the determination of GFAP in human serum

    Science.gov (United States)

    Ma, Yunsu; Xu, Guanhong; Wei, Fangdi; Cen, Yao; Song, Yueyue; Ma, Yujie; Xu, Xiaoman; Shi, Menglan; Sohail, Muhammad; Hu, Qin

    2018-04-01

    Glial fibrillary acidic protein (GFAP) is expressed in the central nervous system and the level of GFAP normally rises with brain injury and astroglial tumors. So, serum GFAP is used as a marker for diagnosing various types of brain damage and astroglial tumors. In this study, a new sensor based on carbon dots (CDs) linked with antibodies to specifically detect GFAP in human serum was developed. Anti-GFAP (Ab1) linked with protein A/G agarose resin (PA/G) as a capture antibody (PA/G-Ab1) and anti-GFAP (Ab2) labeled with CDs as a detection antibody (CDs-Ab2) were prepared firstly. Then the CD-linked antibody immunosorbent assay (CLAISA) method was constructed based on the sandwich conjunction reaction among PA/G-Ab1, GFAP, and CDs-Ab2. CLAISA, using the fluorescence of PA/G-Ab1-GFAP-Ab2-CDs as the direct signal, enabled the proposed immunosensor to detect GFAP sensitively with a linear range of 0.10-8.00 ng ml-1 and a detection limit of 25 pg ml-1. This method was applied to the determination of GFAP in human serum by the standard addition method, and the results showed high accuracy and precision. Considering the easy synthetic process and excellent performance of CLAISA, this method has great potential to be used to monitor GFAP in the clinic.

  10. Diagnostic value of enzyme linked immuno-sorbent assay for cytomegalovirus disease.

    Directory of Open Access Journals (Sweden)

    Priya K

    2002-07-01

    Full Text Available BACKGROUND: Since interpretation of results of enzyme linked immuno-sorbent assay (ELISA for diagnosis of Cytomegalovirus (CMV infection in India is difficult, its diagnostic value required evaluation. AIMS: To evaluate the diagnostic value of ELISA against polymerase chain reaction (PCR in CMV disease. SETTINGS AND DESIGN: Results of ELISA test for CMV antibodies in CMV-DNA PCR positive and negative patients and normal healthy blood donors were analysed. METHODS AND MATERIAL: Anti-CMV antibodies were assayed by ELISA on the sera of 26 CMV PCR positive and 21 PCR negative patients and 35 normal healthy blood donors. STATISTICAL ANALYSIS: Chi square and Fischer exact test were used for statistical analysis. RESULTS: Anti-CMV antibodies (IgG or IgG and IgM were present in 20 (76.9% of 26 PCR positive and 13 (61.9% of 21 PCR negative patients. ELISA was negative in six (23.1% of 26 PCR positive patients. Of the 28 paediatric patients, ELISA was positive in 14 (73.7% of 19 PCR positive and three (33.3% of nine PCR negative patients showing a statistically significant difference (Chi square test, P value 0.038. Among the 19 patients having complications after organ transplant, ELISA showed anti-CMV antibodies in six (85.7% of seven PCR positive and 11 (91.7% of 12 PCR negative patients showing no significant difference. CMV-DNA was not detected in the buffy coat of 35 sero-positive blood donors. CONCLUSION: ELISA has no diagnostic value in the detection of CMV activation although it may help in the differential diagnosis of CMV infection in the paediatric age group.

  11. THE SPOROZOITE ENZYME-LINKED IMMUNOSORBENT ASSAY : APPLICATION IN MALARIA EPIDEMIOLOGY

    Directory of Open Access Journals (Sweden)

    Michael J. Bangs

    2012-09-01

    Full Text Available Recent biotechnological breakthroughs have led to the development of various methods for detection and identification of human pathogens in their vectors. Monoclonal antibodies produced against malaria sporozoite antigens have permitted the development of several sensitive, species specific immunological tests (IFA, IRMA, ELIS A. One of these, a two-site enzyme-linked immunosorbent assay (ELIS A has been developed as a useful epidemiological tool in the identification of malaria-infected mosquitoes. This method employs highly species specific monoclonal antibodies that recognize the repetitive immunodominant epitope of the circumsporozoite (CS protein. Monoclonal antibodies have been developed for all four species of human malaria The key feature of the ELISA technique is the use of an enzyme indicator for an immunological reaction. The antigen capture or "sandwich" ELISA configuration uses the purified monoclonal both as the solid phase and, conjugated to enzyme, as a marker for the presence of CS protein in a mosquito homogenate incubated in the wells of a microtitration plate. This technology has shown advantages over other methods for epidemiological data collection. Mosquitoes can be caught, dried and stored until a time convenient for examination. The sporozoite rate by Plasmodium species can be identified easily, and when combined with the man-biting rate provides the sporozoite inoculation rate, an important entomologic estimate of the number of potential infective bites a person could expect over a given period of time. Presently, mosquitoes can be tested individually or pooled up to 20 anophe lines. The assay is sensitive enough to detect 1 infected mosquito per pool or as few as 25 sporozoites per 50 pi of mosquito extract. Basic principles and procedures are covered concerning solid substrate, adsorption to solid substrate, buffers and wash solutions, conjugates and enzyme substrates. The advantages and limitations of this technique

  12. Direct microculture enzyme-linked immunosorbent assay for studying neural cells: oligodendrocytes.

    Science.gov (United States)

    Gard, A L; Warrington, A E; Pfeiffer, S E

    1988-05-01

    Oligodendrocyte development has been studied in a standardized primary microculture system initiated from day 20-21 fetal rat brain using a solid-phase enzyme-linked immunosorbent assay (ELISA) carried out directly on fixed cells (direct microculture ELISA). A highly reproducible dissociation procedure is described that allows careful control of the number of cells seeded per culture. At a seeding density of 1 x 10(5) cells/culture, up to 250 oligodendrocyte-generating microcultures consisting of 10-12% oligodendrocytes can be prepared from a single fetal rat brain, thereby permitting the simultaneous assay of multiple developmental parameters in sibling cultures. The validity of this method for quantifying myelinogenesis was established by comparing the results obtained by direct microculture ELISA with immunocytochemical counting of cells in parallel cultures. As few as 200 oligodendrocytes could be detected using a biotinylated anti-Ig and an avidin-urease conjugate detection system; CNP immunoreactivity measured by ELISA was linearly proportional to the number of immunolabeled cells between 6 and 34 days in culture; the developmental time courses of 2',3'-cyclic nucleotide 3'-phosphohydrolase (CNP) and myelin basic protein (MBP) expression determined by the two methods were very similar. Finally, cell suspensions were seeded at increasing dilution to determine the number of cells required to generate cultures that tested positive for oligodendrocytes by ELISA. As few as 9,000 cells were sufficient, predicting a minimum of 8,000 oligoprogenitors per 20-21 day fetal rat brain. The application of direct microculture ELISA for studying oligodendrocyte population size and myelinogenesis is discussed.

  13. Diagnosis of Zika Virus Infection by Peptide Array and Enzyme-Linked Immunosorbent Assay

    Directory of Open Access Journals (Sweden)

    Nischay Mishra

    2018-03-01

    Full Text Available Zika virus (ZIKV is implicated in fetal stillbirth, microcephaly, intracranial calcifications, and ocular anomalies following vertical transmission from infected mothers. In adults, infection may trigger autoimmune inflammatory polyneuropathy. Transmission most commonly follows the bite of infected Aedes mosquitoes but may also occur through sexual intercourse or receipt of blood products. Definitive diagnosis through detection of viral RNA is possible in serum or plasma within 10 days of disease onset, in whole blood within 3 weeks of onset, and in semen for up to 3 months. Serological diagnosis is nonetheless critical because few patients have access to molecular diagnostics during the acute phase of infection and infection may be associated with only mild or inapparent disease that does not prompt molecular testing. Serological diagnosis is confounded by cross-reactivity of immune sera with other flaviviruses endemic in the areas where ZIKV has recently emerged. Accordingly, we built a high-density microarray comprising nonredundant 12-mer peptides that tile, with one-residue overlap, the proteomes of Zika, dengue, yellow fever, West Nile, Ilheus, Oropouche, and chikungunya viruses. Serological analysis enabled discovery of a ZIKV NS2B 20-residue peptide that had high sensitivity (96.0% and specificity (95.9% versus natural infection with or vaccination against dengue, chikungunya, yellow fever, West Nile, tick-borne encephalitis, or Japanese encephalitis virus in a microarray assay and an enzyme-linked immunosorbent assay (ELISA of early-convalescent-phase sera (2 to 3 weeks after onset of symptomatic infection.

  14. Optimized enzyme-linked immunosorbent assay for detecting cytomegalovirus infections during clinical trials of recombinant vaccines.

    Science.gov (United States)

    Pagnon, Anke; Piras, Fabienne; Gimenez-Fourage, Sophie; Dubayle, Joseline; Arnaud-Barbe, Nadège; Hessler, Catherine; Caillet, Catherine

    2017-11-01

    In clinical trials of cytomegalovirus (CMV) glycoprotein B (gB) vaccines, CMV infection is detected by first depleting serum of anti-gB antibodies and then measuring anti-CMV antibodies with a commercially available enzyme-linked immunosorbent assay (ELISA) kit, with confirmation of positive findings by immunoblot. Identification of CMV immunoantigens for the development of an ELISA that detects specifically CMV infection in clinical samples from individuals immunized with gB vaccines. Sensitivity and specificity of ELISAs using antigenic regions of CMV proteins UL83/pp65, UL99/pp28, UL44/pp52, UL80a/pp38, UL57, and UL32/pp150 were measured. An IgG ELISA using a UL32/pp150 [862-1048] capture peptide was the most specific (93.7%) and sensitive (96.4%) for detecting CMV-specific antibodies in sera. The ELISA successfully detected CMV-specific antibodies in 22 of 22 sera of subjects who had been vaccinated with a gB vaccine but who had later been infected with CMV. The ELISA was linear over a wide range of CMV concentrations (57-16,814 ELISA units/mL) and was reproducible as indicated by a 5% intra-day and 7% inter-day coefficients of variation. The signal was specifically competed by UL32/pp150 [862-1048] peptide but not by CMV-gB or herpes simplex virus 2 glycoprotein D. Lipid and hemoglobin matrix did not interfere with the assay. The UL32/pp150 [862-1048] IgG ELISA can be used for the sensitive and specific detection of CMV infection in gB-vaccinated individuals. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Enzyme-linked immunosorbent assay for total sennosides using anti-sennside A and anti-sennoside B monoclonal antibodies.

    Science.gov (United States)

    Morinaga, Osamu; Uto, Takuhiro; Sakamoto, Seiichi; Tanaka, Hiroyuki; Shoyama, Yukihiro

    2009-01-01

    Total sennosides concentration is a very important factor when rhubarb and senna will be used as crude drugs. However, one-step analytical technique for total sennosides has not been reported except HPLC. An enzyme-linked immunosorbent assay (ELISA) for total sennosides concentration by using the combination of anti-sennoside A (SA) and anti-sennoside B (SB) monoclonal antibodies (MAbs) in a single assay has been investigated. Total sennosides concentration in rhubarb and senna samples determined by newly developed assay system showed good agreement with those analyzed by ELISA using anti-SA MAb and anti-SB MAb, respectively.

  16. Serodiagnosis of cutaneous leishmaniasis: assessment of an enzyme-linked immunosorbent assay using a peptide sequence from gene B protein

    DEFF Research Database (Denmark)

    Jensen, A T; Gaafar, A; Ismail, A

    1996-01-01

    An enzyme-linked immunosorbent assay (ELISA) using a 28 amino acid sequence of the repetitive element of gene B protein (GBP) from Leishmania major was developed for serodiagnosis of cutaneous leishmaniasis (CL). The assay was compared to ELISAs using crude amastigote and promastigote antigens from...... samples from healthy Sudanese individuals living in an area endemic for malaria but free of leish-maniasis were negative in all the assays. Significantly higher levels of antibodies were found in the patients who had suffered from the disease for more than eight weeks than in patients with a shorter...

  17. Thermometric enzyme linked immunosorbent assay in continuous flow system: optimization and evaluation using human serum albumin as a model system.

    Science.gov (United States)

    Borrebaeck, C; Börjeson, J; Mattiasson, B

    1978-06-15

    Thermometric enzyme-linked immunosorbent assay (TELISA) is described. After the procedure of optimization, human serum albumin was assayed using anti-human serum albumin bound to Sepharose CL 4-B in the enzyme thermistor unit and catalase as label on the free antigen. The model system was used for assays down to 10(-13)M and the preparation of immobilized antibodies was used repeatedly up to 100 times. Comparative studies of the TELISA technique with bromocresol green, immunoturbidimetric and rocket immunoelectrophoretic methods were carried out and showed that TELISA could be used as an alternative method.

  18. Using an enzyme linked immunosorbent assay (ELISA) and a protein phosphatase inhibition assay (PPIA) for the detection of microcystins and nodularins.

    Science.gov (United States)

    Carmichael, W W; An, J

    1999-01-01

    Cyanotoxins produced by cyanobacteria (blue-green algae) include potent neurotoxins and hepatotoxins. The hepatotoxins include cyclic peptide microcystins and nodularins plus the alkaloid cylindrospermopsins. Among the cyanotoxins the microcystins have proven to be the most widespread, and are most often implicated in animal and human poisonings. This paper presents a practical guide to two widely used methods for detecting and quantifying microcystins and nodularins in environmental samples-the enzyme linked immunosorbant assay (ELISA) and the protein phosphatase inhibition assay (PPIA).

  19. Enzyme-linked immunosorbent Assay for detecting of antibody to canine distemper virus

    Directory of Open Access Journals (Sweden)

    Sudarisman

    2006-03-01

    Full Text Available Serum neutralisation test (SNT has been established for evaluating canine distemper vaccination, but until now SNT was rarely used due to the need for continuous tissue culture facilities and requires 3 days to perform. For detecting antibody to canine distemper virus, an enzyme-linked immunosorbent assay (ELISA is relatively simple and rapid seroassay. ELISA for canine immunoglobulin (Ig G antibodies to canine distemper virus (CDV was developed by using Onderstepoort strain of canine distemper virus as coating antigen. Rabbit anti canine IgG labelled with horse radish peroxidase was used as the conjugate, while phenylenediamine dihydrochloride (OPD was used as the substrate. The ELISA results were then compared with the results of the SNT, using the sera of 312 random-source dogs from West Java. The two test-results had a high degree of correlation. Very few discrepancies occurred and most of these were at the lower limits of each test. When the sera were tested at 1 : 100 dilutions, there was a 95.5% agreement between the ELISA and SNT. Their sensitivity and spesificity were 83.9 and 98.4%. Titrated SNT and ELISA also were performed on sera from 7 dogs whose lifetime medical histories were known. The antibodies were inclining up after two months of post vaccination, where the titre was not in zero/lower position at the day of vaccination. However, antibody zero or low position were found at 28 days post vaccination. All of the results indicated that ELISA can be used for evaluating antibody to canine distemper virus response, replacing the SNT.

  20. Serum biotin in Japanese children: Enzyme-linked immunosorbent assay measurement.

    Science.gov (United States)

    Wakabayashi, Kenji; Kodama, Hiroko; Ogawa, Eishin; Sato, Yasuhiro; Motoyama, Kahoko; Suzuki, Mitsuyoshi

    2016-09-01

    Biotin deficiency has been reported in Japanese infants fed special formulas for medical reasons, including those with milk allergy and congenital metabolic diseases, because these formulas contain little biotin. Serum biotin measurement is useful for diagnosing biotin deficiency. We applied a simple and rapid method to analyze serum biotin, and established normal ranges for children and adults. Serum biotin in 188 healthy Japanese children aged 0-4 years and in 25 healthy adults was analyzed using a Biotin ELISA Kit (immundiagnostik). The effects of various conditions on the measurement of serum biotin were also examined. Median biotin in children aged 0-4 years was 10.4 ng/dL (IQR, 7.9-13.4 ng/dL), and that in adults was 12.9 ng/dL (IQR, 10.8-15.8 ng/dL). Normal range was 4.7-22.0 ng/dL in children and 8.4-20.5 ng/dL in adults (calculated using two-sided 95%CI). Measurements obtained with this method were not affected by frozen storage, freeze-thaw, or hemolysis, indicating that serum biotin can be analyzed accurately under these conditions, with a possible application to plasma samples. Serum biotin was significantly lower in children than in adults, with the normal range being 4.7-22.0 ng/dL in children and 8.4-20.5 ng/dL in adults. This simple and accurate enzyme-linked immunosorbent assay method is useful for diagnosing biotin deficiency. © 2016 The Authors. Pediatrics International published by John Wiley & Sons Australia, Ltd on behalf of Japan Pediatric Society.

  1. Enzyme linked immunosorbent assay for detecting antibody to Trichomonas vaginalis: use of whole cells and aqueous extract as antigen.

    OpenAIRE

    Alderete, J F

    1984-01-01

    An enzyme linked immunosorbent assay (ELISA) for detecting antibody to antigenic Trichomonas vaginalis macromolecules has been identified using whole cells or an aqueous protein extract as antigen. The test was developed under optimum conditions using serum samples from experimental animals. The sensitivity of the ELISA was equal to or greater than that obtained by radioimmunoprecipitation and electrophoresis-fluorography techniques. The ELISA was capable of assessing antibody responses durin...

  2. Differentiation of ruminal bacterial species by enzyme-linked immunosorbent assay using egg yolk antibodies from immunized chicken hens.

    OpenAIRE

    Ricke, S C; Schaefer, D M; Cook, M E; Kang, K H

    1988-01-01

    Cross-reactivity among four species of ruminal bacteria was examined by using egg yolk antibodies from immunized Leghorn laying hens and an enzyme-linked-immunosorbent assay. The effects of the four species on the hens were compared on various days postimmunization. Hens injected with the same bacterial species had similar apparent antibody levels over the entire postimmunization period, but only Bacteroides ruminicola B1(4) and Selenomonas ruminantium D antigens elicited early increases in a...

  3. Identification of a Vesicular-Arbuscular Mycorrhizal Fungus by Using Monoclonal Antibodies in an Enzyme-Linked Immunosorbent Assay

    OpenAIRE

    Wright, Sara F.; Morton, Joseph B.; Sworobuk, Janis E.

    1987-01-01

    Spore morphology is currently used to identify species of vesicular-arbuscular mycorrhizal fungi. We report the first use of a highly specific immunological method for identification of a vesicular-arbuscular mycorrhizal fungus. Two monoclonal antibodies were produced against Glomus occultum. Monoclonal antibodies reacted strongly with both spores and hyphae in an indirect enzyme-linked immunosorbent assay. All other mycorrhizal (29 species) and nonmycorrhizal (5 species) fungi tested were no...

  4. An improved enzyme-linked immunosorbent assay for whole-cell determination of methanogens in samples from anaerobic reactors

    DEFF Research Database (Denmark)

    Sørensen, A.H.; Ahring, B.K.

    1997-01-01

    An enzyme-linked immunosorbent assay was developed for the detection of whole cells of methanogens in samples from anaerobic continuously stirred tank digesters treating slurries of solid waste. The assay was found to allow for quantitative analysis of the most important groups of methanogens......-quality microtiter plates and the addition of dilute hydrochloric acid to the samples. In an experiment on different digester samples, the test demonstrated a unique pattern of different methanogenic strains present in each sample. The limited preparatory work required for the assay and the simple assay design make...... in samples from anaerobic digesters in a reproducible manner. Polyclonal antisera against eight strains of methanogens were employed in the test, The specificities of the antisera were increased by adsorption with cross-reacting cells. The reproducibility of the assay depended on the use of high...

  5. Micro-enzyme-linked immunosorbent assay (ELISA) and radioimmunosorbent technique (RIST) for the detection of immunity to clinical tetanus

    Energy Technology Data Exchange (ETDEWEB)

    Layton, G T [Royal Infirmary, Manchester (UK)

    1980-10-01

    Enzyme-linked immunosorbent assay (ELISA), and radioimmunosorbent assay (RIST) techniques for the detection of tetanus toxin antibodies are described. Both methods proved to be highly sensitive, and allowed the measurement of 5 x 10/sup -3/ units/ml tetanus antitoxin in human serum or plasma, sensitivity and reproducibility comparing well with other techniques previously described, and being superior to haemagglutination and latex agglutination tests. Results of the two methods correlated well, and reflected the immunization histories obtained. Micro ELISA and micro RIST would seem to be suitable for the detection of immunity, or non-immunity to clinical tetanus.

  6. A micro-enzyme-linked immunosorbent assay (ELISA) and radioimmunosorbent technique (RIST) for the detection of immunity to clinical tetanus

    International Nuclear Information System (INIS)

    Layton, G.T.

    1980-01-01

    Enzyme-linked immunosorbent assay (ELISA), and radioimmunosorbent assay (RIST) techniques for the detection of tetanus toxin antibodies are described. Both methods proved to be highly sensitive, and allowed the measurement of 5 x 10 -3 units/ml tetanus antitoxin in human serum or plasma, sensitivity and reproducibility comparing well with other techniques previously described, and being superior to haemagglutination and latex agglutination tests. Results of the two methods correlated well, and reflected the immunization histories obtained. Micro ELISA and micro RIST would seem to be suitable for the detection of immunity, or non-immunity to clinical tetanus. (author)

  7. Enzyme-linked immunosorbent assay characterization of Basal variation and heritability of systemic microfibrillar-associated protein 4

    DEFF Research Database (Denmark)

    Sækmose, Susanne Gjørup; Schlosser, Anders; Holst, René

    2013-01-01

    Microfibrillar-associated protein 4 (MFAP4) is a systemic biomarker that is significantly elevated in samples from patients suffering from hepatic cirrhosis. The protein is generally localized to elastic fibers and other connective tissue fibers in the extracellular matrix (ECM), and variation...... in systemic MFAP4 (sMFAP4) has the potential to reflect diverse diseases with increased ECM turnover. Here, we aimed to validate an enzyme-linked immunosorbent assay (ELISA) for the measurement of sMFAP4 with an emphasis on the robustness of the assay. Moreover, we aimed to determine confounders influencing...

  8. Detection of antibodies to Actinobacillus pleuropneumoniae serotype 12 in pig serum using a blocking enzyme-linked immunosorbent assay

    DEFF Research Database (Denmark)

    Andresen, Lars Ole; Klausen, Joan; Barfod, Kristen

    2002-01-01

    and from herds declared free of infection with Ap. The Ap serotype 12 blocking ELISA showed a herd sensitivity of 0.77 (95% confidence interval, 0.62-0.88) and a herd specificity of 1.00 (0.95-1.00) with a cut-off value at 40% relative absorbance or 60% inhibition. The assay may be used advantageously......The objective was to develop a blocking enzyme-linked immunosorbent assay (ELISA) for detection of antibodies to Actinobacillus pleuropneumoniae (Ap) serotype 12 in pig serum. Lipopolysaccharide (LPS) from Ap serotype 12 was purified and used as antigen in the assay. Antibodies to the LPS antigen...... in samples of pig serum were detected by inhibition of the binding of polyclonal rabbit antibodies raised against Ap serotype 12. The assay was evaluated against sera from experimentally infected pigs, from pig herds naturally infected with Ap and from herds declared free of Ap serotypc 12 infection...

  9. Environmental Technology Verification Report for Abraxis Ecologenia® 17β-Estradiol (E2) Microplate Enzyme-Linked Immunosorbent Assay (ELISA) Test Kits

    Science.gov (United States)

    This verification test was conducted according to procedures specifiedin the Test/QA Planfor Verification of Enzyme-Linked Immunosorbent Assay (ELISA) Test Kis for the Quantitative Determination of Endocrine Disrupting Compounds (EDCs) in Aqueous Phase Samples. Deviations to the...

  10. Validation of 2 commercially available enzyme-linked immunosorbent assays for adiponectin determination in canine serum samples.

    Science.gov (United States)

    Tvarijonaviciute, Asta; Martínez-Subiela, Silvia; Ceron, José J

    2010-10-01

    The aim of this study was to validate 2 commercially available enzyme-linked immunosorbent assays (ELISAs) for adiponectin in dogs, 1 canine-specific and 1 originally designed for measurements in humans. Intra-assay and interassay precision was evaluated by multiple measurements in canine serum samples, and assay accuracy was indirectly determined by linearity under dilution. Interference caused by hemolysis and lipemia was also studied. Both assays were subsequently used for measuring adiponectin concentrations in clinically healthy dogs and those with different grades of obesity. The intra-assay and inter-assay precision was less than 7.5% and 13.5% in serum samples with low and high adiponectin concentrations, respectively. Lipemia and hemolysis did not affect the results of any of the assays. Both assays were able to differentiate lean dogs from those that were overweight or obese on the basis of the measured adiponectin concentrations. From these results it can be concluded that canine adiponectin concentrations can be measured reliably by means of the 2 ELISAs evaluated in this study.

  11. Evaluation of immunofluorescence microscopy and enzyme-linked immunosorbent assay in detection of Cryptosporidium and Giardia infections in asymptomatic dogs

    DEFF Research Database (Denmark)

    Rimhanen-Finne, R.; Enemark, Heidi L.; Kolehmainen, J.

    2007-01-01

    The performance of immunofluorescence microscopy (IF) and enzyme-linked immunosorbent assay (ELISA) in canine feces was evaluated. IF and Cryptosporidium ELISA detected 10(5) oocysts/g, while the detection limit for Giardia ELISA was 10(4) cysts/g. The Cryptosporidium ELISA showed 94% specificity...... zoonotic character of Cryptosporidium and Giardia infections in 150 asymptomatic Finnish dogs from the Helsinki area were studied. The overall proportion of dogs positive for Cryptosporidium was 5% (7/150) and that for Giardia 5% (8/150). In dogs...

  12. Evaluation of a covalent mix-enzyme linked immunosorbent assay for screening of Salmonella antibodies in pig serum

    DEFF Research Database (Denmark)

    Chow, E.Y.W.; Wu, J.T.Y.; Jauho, E.S.

    2004-01-01

    In this study, a commercial Salmonella covalent mix-enzyme linked immunosorbent assay (ELISA) for serological detection of Salmonella infection in swine was evaluated by comparing it with the conventional fecal culture method and inter-laboratory proficiency testing, using a panel of sera tested.......9% tested negative. The interlaboratory comparison study found a kappa value of 0.9 between our laboratory (using an automated system) and the manufacturer laboratory (using the manual method). Comparison of ELISA results from all 5 participating laboratories showed very good to excellent agreement, between...

  13. Development and evaluation of a blocking enzyme-linked immunosorbent assay and virus neutralization assay to detect antibodies to viral hemorrhagic septicemia virus

    Science.gov (United States)

    Wilson, Anna; Goldberg, Tony; Marcquenski, Susan; Olson, Wendy; Goetz, Frederick; Hershberger, Paul; Hart, Lucas M.; Toohey-Kurth, Kathy

    2014-01-01

    Viral hemorrhagic septicemia virus (VHSV) is a target of surveillance by many state and federal agencies in the United States. Currently, the detection of VHSV relies on virus isolation, which is lethal to fish and indicates only the current infection status. A serological method is required to ascertain prior exposure. Here, we report two serologic tests for VHSV that are nonlethal, rapid, and species independent, a virus neutralization (VN) assay and a blocking enzyme-linked immunosorbent assay (ELISA). The results show that the VN assay had a specificity of 100% and sensitivity of 42.9%; the anti-nucleocapsid-blocking ELISA detected nonneutralizing VHSV antibodies at a specificity of 88.2% and a sensitivity of 96.4%. The VN assay and ELISA are valuable tools for assessing exposure to VHSV.

  14. Development of direct competitive biomimetic immunosorbent assay based on quantum dot label for determination of trichlorfon residues in vegetables.

    Science.gov (United States)

    Liu, Qiurui; Jiang, Mingdi; Ju, Zeliang; Qiao, Xuguang; Xu, Zhixiang

    2018-06-01

    A direct competitive biomimetic immunosorbent assay method based on molecularly imprinted polymer was developed for the determination of trichlorfon. A CdSe/ZnS quantum dot label was used as the marker. The hydrophilic imprinted film was synthesized directly on the surface of a 96-well plate, and characterized by Fourier-transform infrared spectroscopy and thermo-gravimetric analyses. The method exhibited high stability, selectivity, and sensitivity. Under optimal conditions, the limits of detection and sensitivity of the biomimetic immunosorbent assay method were 9.0 μg L -1 and 5.0 mg L -1 (0.1 mg kg -1 and 62.5 mg kg -1 for vegetable sample), respectively. Low cross-reactivity values of 19.2% and 15.6% were obtained for the structural analogues. Spinach and rape samples spiked with trichlorfon were extracted and determined by this method with recoveries ranging from 83.6% to 91.1%. The method was applied for the detection of trichlorfon residues in leek and cucumber samples, and results correlated well with those obtained using GC. Copyright © 2018 Elsevier Ltd. All rights reserved.

  15. Evaluation of Two Commercial Enzyme-Linked Immunosorbent Assay Kits for the Detection of Human Circulating Metrnl.

    Science.gov (United States)

    Zheng, Si-Li; Li, Zhi-Yong; Zhang, Zheng; Wang, Dong-Sheng; Xu, Jian; Miao, Chao-Yu

    2018-04-01

    Metrnl is a newly discovered secreted protein with neurotrophic activity and metabolic effect, while in earlier studies its circulating level in human was not explored. We evaluated two commercial enzyme-linked immunosorbent assay kits (DY7867-05, R&D Systems and SK00478-02, Aviscera Bioscience) for the detection of human circulating Metrnl. The DY7867-05 kit showed superiority over the SK00478-02 kit since it generated better curve fitting degree, smaller variation among tests, higher inter-assay reproducibility and better specificity, and could effectively detect human Metrnl in six types of blood samples. Subsequent analysis was performed using the DY7867-05 kit. Sample storage conditions were investigated. No gender difference in circulating Metrnl levels was found, while people with newly diagnosed type 2 diabetes mellitus (T2DM) had significantly lower Metrnl levels compared to the healthy controls.

  16. An enzyme-linked immunosorbent assay (ELISA) for quantification of human collectin 11 (CL-11, CL-K1)

    DEFF Research Database (Denmark)

    Selman, L; Henriksen, M L; Brandt, J

    2012-01-01

    -associated serine protease 1 (MASP-1) and/or MASP-3 in circulation. Mutation in the CL-11 gene was recently associated with the developmental syndrome 3MC. In the present study, we established and thoroughly validated a sandwich enzyme-linked immunosorbent assay (ELISA) based on two different monoclonal antibodies....... The assay is highly sensitive, specific and shows excellent quantitative characteristics such as reproducibility, dilution linearity and recovery (97.7-104%). The working range is 0.15-34 ng/ml. The CL-11 concentration in two CL-11-deficient individuals affected by the 3MC syndrome was determined...... and thawing to a certain extent did not influence the ELISA. This ELISA offers a convenient and reliable method for studying CL-11 levels in relation to a variety of human diseases and syndromes....

  17. Evaluation of a competitive enzyme-linked immunosorbent assay for measurements of soluble HLA-G protein

    DEFF Research Database (Denmark)

    Rasmussen, M; Dahl, M; Buus, S

    2014-01-01

    . We report a novel method, a competitive immunoassay, for measuring HLA-G5/sHLA-G1 in biological fluids. The sHLA-G immunoassay is based upon a competitive enzyme-linked immunosorbent assay (ELISA) principle. It includes a recombinant sHLA-G1 protein in complex with β2-microglobulin and a peptide...... as a standard, biotinylated recombinant sHLA-G1 as an indicator, and the MEM-G/9 anti-HLA-G monoclonal antibody (mAb) as the capture antibody. The specificity and sensitivity of the assay were evaluated. Testing with different recombinant HLA class I proteins and different anti-HLA class I mAbs showed....../ml. An intra-assay coefficient of variation (CV) of 15.5% at 88 ng/ml and an inter-assay CV of 23.1% at 39 ng/ml were determined. An assay based on the competitive sHLA-G ELISA may be important for measurements of sHLA-G proteins in several conditions: assisted reproduction, organ transplantation, cancer...

  18. Serodiagnosis of Leishmania donovani infections: assessment of enzyme-linked immunosorbent assays using recombinant L. donovani gene B protein (GBP) and a peptide sequence of L. donovani GBP

    DEFF Research Database (Denmark)

    Jensen, A T; Gasim, S; Moller, T

    1999-01-01

    The repetitive sequence of Leishmania major gene B protein (GBP) has previously been shown to be a useful tool in the diagnosis of cutaneous leishmaniasis (CL). Here, we have assessed enzyme-linked immunosorbent assays (ELISAs) using recombinant L. donovani GBP (rGBP) and a peptide sequence of L...... for malaria but free of leishmaniasis was negative in both assays....

  19. Development of a Multianalyte Enzyme-Linked Immunosorbent Assay for Permethrin and Aroclors and Its Implementation for Analysis of Soil/Sediment and House Dust ExtractsExtracts

    Science.gov (United States)

    Development of a multianalyte enzyme-linked immunosorbent assay (ELISA) for detection of permethrin and aroclors 1248 or 1254, and implementation of the assay for analysis of soil/sediment samples are described. The feasibility of using the multianalyte ELISA to monitor aroclors ...

  20. Validation of an improved enzyme-linked immunosorbent assay for the diagnosis of trypanosomal antibodies in Ghanaian cattle

    International Nuclear Information System (INIS)

    Doku, C.K.; Seidu, I.B.M.

    2000-01-01

    The validation of an enzyme-linked immunosorbent assay (Ab-ELISA) for the detection of antibodies to pathogenic trypanosomes in cattle is described. Two hundred known negative sera obtained from the tsetse-free zone of Dori (Burkina Faso) were analyzed using microtitre plates pre-coated with crude antigen lysates of Trypanosoma congolense and T. vivax. A pre-test optimization was carried out and a percent positivity (PP) of 50% was chosen (specificity: >82%) for assaying field sera. A total of 440 serum samples collected from cattle in areas of known and unknown disease prevalence were assayed. For all animals the packed red cell volume (PCV) was determined and the buffy coat technique (BCT) and blood smears were examined to detect trypanosomes at the species level. A comparison of the BCT and Ab-ELISA results showed there was a much higher prevalence of antibodies to both species than the parasite prevalence as shown by the BCT (10 fold). The rate of agreement between BCT-positive and Ab-ELISA-positive samples for both species was low (<10%). No conclusion could be drawn from this finding because of the low number of known BCT positive cases that were identified. There was a better, albeit highly variable, agreement between BCT-negative and Ab-ELISA-negative samples (30-70%). Proposals for further improvement of the Ab-ELISA and prospects for the use of the assay in the monitoring of trypanosomosis control in Ghana are discussed. (author)

  1. Evaluation of the radioimmunoassay, indirect enzyme linked immunosorbent assay, and dot blot assay for the identification of Xanthomonas campestris pv. phaseoli

    Energy Technology Data Exchange (ETDEWEB)

    Malin, E; Belden, E L; Roth, D

    1985-09-01

    A radioimmunoassay (RIA), an indirect competitive enzyme-linked immunosorbent assay (ELISA), and a dot-blot modification of the ELISA were evaluated for detection and identification of Xanthomonas campestris pv. phaseoli (X. c. pv. phaseoli). RIA and the dot blot tests were specific for X. c. pv. phaseoli; however, significant cross reactions occurred in the indirect competitive ELISA when using anti-X. c. pv. phaseoli antiserum against other closely related bacteria. The sensitivity level of all procedures for X. c. pv. phaseoli was approximately l0/sup 5/ colony forming unitsmL. All procedures were unsatisfactory in reliably detecting low levels of X. c. pv. phaseoli directly from extracts of bean seed. However when used in conjunction with ilution plating the dot blot assay and the RIA would be useful in specifically identifying X. c. pv. phaseoli. The relative merits of these tests for identification of X. c. pv. phaseoli are discussed.

  2. Evaluation of a commercially available enzyme-linked immunosorbent assay for the diagnosis of canine sarcoptic mange.

    Science.gov (United States)

    Curtis, C F

    2001-02-24

    This study was designed to assess the accuracy of a commercial enzyme-linked immunosorbent assay for the diagnosis of canine scabies. Serum samples from 37 dogs were examined blind; 12 had sarcoptic mange confirmed by the identification of mites in skin scrapings, 12 were atopic (with positive intradermal reactions to one or more aeroallergens, including Dermatophagoides farinae), and 13 were healthy dogs with no history of skin disease. Optical density values of more than 0.16 were considered positive, 0.145 to 0.16 were considered questionable and less than 0.145 were considered negative. Ten of the 12 dogs with scabies were positive, all 12 atopic dogs were negative, and 11 of the 13 healthy dogs were negative and two were questionable.

  3. Evaluation of an enzyme-linked immunosorbent assay (ELISA) for the serological diagnosis of sarcoptic mange in dogs.

    Science.gov (United States)

    Lower, K S; Medleau, L M; Hnilica, K; Bigler, B

    2001-12-01

    Canine scabies is a challenging disease to diagnose because sarcoptic mites are hard to find on skin scrapings. The purpose of this study was to evaluate a serologic enzyme-linked immunosorbent assay (ELISA) as an aid in the diagnosis of canine scabies. In addition, serum samples were obtained post treatment to determine the duration and persistence of circulating scabies antibodies after resolution of natural infection. Nineteen dogs diagnosed with sarcoptic mange and 38 control dogs were tested. Sixteen scabies-infested dogs showed positive pretreatment ELISA results (84.2% sensitivity). Thirty-four control dogs showed negative ELISA results (89.5% specificity). In the 11 scabies dogs from which multiple post treatment serum samples were obtained, detectable antibodies were not present 1 month after treatment in four cases, but were present for 1-4.5 months post treatment in seven dogs. Our results suggest that this scabies ELISA test is useful in the diagnosis of canine scabies.

  4. Seroprevalence of Japanese encephalitis virus using competitive enzyme linked immunosorbent assay (C-ELISA in pigs in East Sumba, Indonesia

    Directory of Open Access Journals (Sweden)

    Annytha Detha

    2015-12-01

    Full Text Available Japanese Encephalitis (JE, a vector-borne zoonotic viral disease, is mostly prevalent in Asian countries. The objective of this study was to investigate the occurence of JE virus (JEV among pigs in East Sumba, Indonesia. Blood samples (n=52 were randomly collected from 52 apparantly healthy pigs where pig population was high in East Sumba. The samples were subjected for seroprevalence study for the presence of antibodies against JEV using competitive enzyme linked immunosorbent assay (C-ELISA. Results showed that 53% (n=28/52 blood samples from the pigs contained antibodies against JEV. This finding is suggestive that the JEV is circulating among pig population in East Sumba, Indonesia. The data may help in designing control strategies of the JEV in the East Sumba, Indonesia.

  5. An enzyme-linked immunosorbent assay (ELISA) for quantification of mouse surfactant protein D (SP-D)

    DEFF Research Database (Denmark)

    Hansen, Soren; Schmidt, Vivi; Steffensen, Maria Abildgaard

    2008-01-01

    characterized and validated for use in sandwich enzyme-linked immunosorbent assay (ELISA). Based on two of these, we established an ELISA that allows for measurements of mouse SP-D in various body fluids. The final ELISA was optimized and calibrated with a standard of purified recombinant mouse SP-D, which......Surfactant protein D (SP-D) is a pattern recognition molecule of the collectin family of C-type lectins. It is found in the airways and at mucosal surfaces. SP-D is part of the innate immune system where it neutralizes and leads to elimination of microorganisms. It regulates the functions of other...... innate immune cells, such as macrophages and neutrophils. It also modulates the adaptive immune response by interacting with antigen-presenting cells and T cells. Monoclonal anti-mouse-SP-D antibodies were raised from SP-D deficient mice using recombinant SP-D as antigen. Ten monoclonal antibodies were...

  6. Immunodiagnosis of fascioliasis using sandwich enzyme-linked immunosorbent assay for detection of Fasciola gigantica paramyosin antigen

    Science.gov (United States)

    Abou-Elhakam, Hany Mohamed Adel; Bauomy, Ibraheem Rabia; El Deeb, Somaya Osman; El Amir, Azza Mohamed

    2013-01-01

    Background: Many immunological techniques have been developed over years using the different Fasciola antigens for diagnosis of parasitic infection and to replace the parasitological techniques, which are time consuming and usually lack sensitivity and reproducibility. Materials and Methods: In this study, Fasciola gigantica paramyosin (Pmy) antigen was early detected in cattle sera using sandwich enzyme-linked immunosorbent assay (ELISA), to evaluate the Pmy antigen performance in diagnosis. This work was conducted on 135 cattle blood samples, which were classified according to parasitological investigation into, healthy control (30), fascioliasis (75), and other parasites (30) groups. Results: The sensitivity of Sandwich ELISA was 97.33%, and the specificity was 95%, in comparison with parasitological examination, which recorded 66.66% sensitivity and 100% specificity, respectively. Conclusions: It was clear that the native F. gigantica Pmy is considered as a powerful antigen in early immunodiagnosis of fascioliasis, using a highly sensitive and specific sandwich ELISA technique. PMID:23961441

  7. Definition of purified enzyme-linked immunosorbent assay antigens from the culture filtrate protein of Mycobacterium bovis by proteomic analysis.

    Science.gov (United States)

    Cho, Yun Sang; Lee, Sang-Eun; Ko, Young Joon; Cho, Donghee; Lee, Hyang Shim; Hwang, Inyeong; Nam, Hyangmi; Heo, Eunjung; Kim, Jong Man; Jung, Sukchan

    2009-01-01

    Enzyme-linked immunosorbent assay (ELISA) has been developed as the ancillary diagnosis of bovine tuberculosis at ante-mortem to overcome the disadvantages of intradermal skin test. In this study, the antigenic proteins were purified, applied to bTB ELISA, and identified through proteomic analysis. Culture filtrate protein of Mycobacterium bovis was fractionated by MonoQ column chromatography, and examined the antigenicity by immunoblotting. The antigenic 20 kDa protein was in-gel digested and identified the antigenome by LTQ mass spectrometer and peptide match fingerprinting, which were MPB64, MPB70, MPB83, Fas, Smc, Nrp, RpoC, Transposase, LeuA, and MtbE. The 20 kDa protein exhibited the highest antigenicity to bTB positive cattle in ELISA and would be useful for bTB serological diagnosis.

  8. Identification of a vesicular-arbuscular mycorrhizal fungus by using monoclonal antibodies in an enzyme-linked immunosorbent assay.

    Science.gov (United States)

    Wright, S F; Morton, J B; Sworobuk, J E

    1987-09-01

    Spore morphology is currently used to identify species of vesicular-arbuscular mycorrhizal fungi. We report the first use of a highly specific immunological method for identification of a vesicular-arbuscular mycorrhizal fungus. Two monoclonal antibodies were produced against Glomus occultum. Monoclonal antibodies reacted strongly with both spores and hyphae in an indirect enzyme-linked immunosorbent assay. All other mycorrhizal (29 species) and nonmycorrhizal (5 species) fungi tested were nonreactive with the monoclonal antibodies. A single spore of G. occultum was detectable in the presence of high numbers of spores of other vesicular-arbuscular mycorrhizal fungi. Variation in the reaction of G. occultum isolates from West Virginia, Florida, and Colombia suggests that monoclonal antibodies may differentiate strains.

  9. Sandwich enzyme-linked immunosorbent assay (ELISA) for measuring the concentration of, and detection of antibodies to, Aujeszky's disease virus.

    Science.gov (United States)

    Kardi, V; Szegletes, E; Perényi, T; Pergel, I; Smal, Z

    1990-01-01

    A double antibody sandwich enzyme-linked immunosorbent assay (ELISA) was developed for measuring Aujeszky's disease virus (ADV) antigen concentration and an inhibition technique based on the former was developed for detection of antibodies to ADV. The results were checked by determining the cytopathic and serum neutralization titres. The correlation was satisfactory in both cases, with correlation coefficients above 0.8. When measuring ADV antigen concentration, the lower limit of detection was 10(3) TCID 50/0.2 ml. The sensitivity of ELISA in detecting antibodies to ADV was found to be superior to that of the serum neutralization test and, thus, enabled the testing of rabbit and guinea-pig sera.

  10. Enzyme-linked immunosorbent assays for insulin-like growth factor-I using six-histidine tag fused proteins

    International Nuclear Information System (INIS)

    Huang Yong; Shi Ruina; Zhong Xuefei; Wang Dan; Zhao Meiping; Li Yuanzong

    2007-01-01

    The fusion proteins of insulin-like growth factor-I (IGF-I) and six-histidine tag (IGF-I-6H, 6H-IGF-I-6H) were cloned, expressed, purified and renatured, with their immunoreaction properties and biological activities intact. The binding kinetics between these fusion proteins and anti-IGF-I antibody or anti-6H antibody were studied using surface plasmon resonance (SPR). Two enzyme-linked immunosorbent assay (ELISA) modes, which proved feasible in the measurement of human serum samples, were used to detect IGF-I with the help of the six-histidine tagged proteins. Furthermore, combining the production technique of the six-histidine tagged fusion protein with the competitive sandwich ELISA mode, using an enzyme labeled anti-6H antibody as a tracer, can be a universal immunochemical method to quantitate other polypeptides or proteins

  11. Influenza A plasma and serum virus antibody detection comparison in dogs using blocking enzyme-linked immunosorbent assay

    Directory of Open Access Journals (Sweden)

    H. T. Lin

    2015-05-01

    Full Text Available Background and Aim: The influenza A virus (IAV is an important zoonotic pathogen with infections also reported in dogs. IAV infections can be detected through the presence of antibodies using the enzyme-linked immunosorbent assay (ELISA. Serum is the only standard sample source; however, there is no information on the availability of other sample sources for IAV antibody detection in dogs. Compared with serum, plasma is more widely employed in most animal hospitals. The object of this study is to investigate whether plasma collected in ethylenediaminetetraacetic acid (EDTA tubes (EDTA plasma or heparin tubes (heparin plasma could be used in the ELISA protocol instead of serum for IAV antibody detection in dogs. Materials and Methods: Totally, 82 matched EDTA plasma and serum sample pairs and 79 matched heparin plasma and serum sample pairs were employed using blocking enzyme-linked immunosorbent assay (bELISA. The agreement and correlation between the plasma (EDTA or heparin plasma and serum were assessed using the agreement index kappa (kD calculation and Pearson correlation coefficient, respectively. Results: The agreement index kD of EDTA plasma and serum was 1.0, and that of heparin plasma and serum was 0.85. The Pearson correlation coefficient of EDTA plasma and serum was 0.87 (p<0.01, and that of heparin plasma and serum was 0.82 (p<0.01. Conclusion: The results proved that plasma, especially EDTA plasma, could be substituted for serum in the bELISA test. This might greatly expand the clinical applicability of IAV antibody detection in dogs.

  12. Dot enzyme-linked immunosorbent assay (ELISA) for the detection of Toxocara infection using a rat model.

    Science.gov (United States)

    Paller, Vachel Gay V; Besana, Cyrelle M; Valdez, Isabel Kristine M

    2017-12-01

    Toxocariasis is a zoonotic disease usually caused by dog and cat roundworms, Toxocara canis and T. cati. Detection and diagnosis is difficult in paratenic and accidental hosts, including humans, as they cannot be detected through conventional methods such as fecal examination. Diagnosis therefore relies on immunological methods and molecular methods such as enzyme-linked immunosorbent assay (ELISA) and Western Blot, which are both time-consuming and requires sophisticated equipment. In the Philippines, only a few studies are available on Toxocara seroprevalence. Therefore, there is a need to adapt methods for serodiagnosis of Toxocara infection in humans for the Philippine setting. A dot enzyme linked immunosorbent assay (dot-ELISA) was standardized using T. canis excretory-secretory antigens. Test sera were collected from laboratory rats (Sprague-Dawley strain) experimentally infected with embryonated eggs of T. canis and Ascaris suum as well as rice field rats naturally infected with Taenia taeniaeformis and Nippostrongylus sp. Optimum conditions used were 20 µg/ml antigen concentration and 1:10 serum dilution. The sensitivity, specificity, positive, and negative predictive values were 90% (95% CI 55.5-99.7%), 100% (95% CI 69.2-100.0%), 100% (95% CI 66.4-100%), and 90.9% (95% CI 58.7-99.8%), respectively. Dot-ELISA has the potential to be developed as a cheaper, simpler, and more practical method for detection of anti- Toxocara antibodies on accidental hosts. This is a preliminary study conducted on experimental animals before optimization and standardization for human serum samples.

  13. An enzyme-linked immunosorbent assay and a gold-nanoparticle based immuno chromatographic test for amatoxins using recombinant antibody

    International Nuclear Information System (INIS)

    He, Kuo; Zhao, Ruiping; Wang, Lixia; Feng, Tingting; Wei, Dong; Zhang, Xiuyuan

    2016-01-01

    The authors describe two kinds of rapid assays for the determination of amatoxins in mushrooms. The first is an enzyme-linked immunosorbent assay (ELISA) using horseradish peroxidase. The second is a rapid immuno chromatographic assay that uses colloidal gold as a red label (CG-ICA). Both are based on the use of a well-characterized recombinant single chain variable fragment antibody (named scFv-A4). The half-maximum inhibition concentrations (IC50) of α-amanitin, β-amanitin and γ-amanitin are 78, 85 and 90 ng⋅mL"-"1, and the limits of detection (LODs; for IC15) are 1.9, 2.1 and 2.8 ng⋅mL"-"1. The method was applied to the determination of amanitins in mushrooms, and the LODs for α-amanitin, β-amanitin and γ-amanitin in mushroom samples were found to be 4.9, 6.4 and 8.3 ng⋅mL"-"1. The visual minimum detection limits of the optimized CGIA are 4 and 6 ng⋅mL"-"1 for mushroom samples. The test can be performed within 10 min. The results of the analysis of spiked samples showed that the CG-IA can rapidly and semi-quantitatively quantify amatoxins in mushroom samples on site and at low costs. (author)

  14. Detection of Francisella tularensis-Specific Antibodies in Patients with Tularemia by a Novel Competitive Enzyme-Linked Immunosorbent Assay

    Science.gov (United States)

    Sharma, Neekun; Hotta, Akitoyo; Yamamoto, Yoshie; Fujita, Osamu; Uda, Akihiko; Morikawa, Shigeru; Yamada, Akio

    2013-01-01

    A novel competitive enzyme-linked immunosorbent assay (cELISA) was developed and evaluated for detection of antibodies against Francisella tularensis in humans. The assay is based on the ability of serum antibodies to inhibit the binding of monoclonal antibodies (MAbs) directed against F. tularensis lipopolysaccharide antigens. The assay was evaluated using serum samples of tularemia patients, inactivated F. tularensis-immunized rabbits, and F. tularensis-infected mice. Antibodies against F. tularensis were successfully detected in serum samples of tularemia patients as well as the immunized and infected animals. The cELISA method was compared to indirect ELISA (iELISA) and the commonly used microagglutination test (MA) using serum samples of 19 tularemia patients and 50 healthy individuals. The sensitivity and specificity of cELISA were 93.9 and 96.1%, respectively, in comparison to the iELISA. MA was less sensitive than cELISA with a sensitivity and specificity of only 81.8 and 98.0%, respectively. A high degree of correlation (R2 = 0.8226) was observed between cELISA and iELISA results. The novel cELISA developed in this study appears to be highly sensitive and specific for serodiagnosis of human tularemia. The potential of the MAb-based cELISA to be used in both human and animal samples emphasizes its usefulness for serological survey of tularemia among multiple animal species. PMID:23114700

  15. Detection by radioimmunoassay and enzyme-linked immunosorbent assay of coronavirus antibodies in bovine serum and lacteal secretions.

    Science.gov (United States)

    Rodak, L; Babiuk, L A; Acres, S D

    1982-07-01

    The sensitivity of a radioimmunoassay (RIA), an enzyme-linked immunosorbent assay (ELISA), and a serum neutralization assay (SN) for detecting antibodies to bovine coronavirus in serum and colostrum were compared. Although there proved to be a good correlation among all three assays (r = 0.915 and 0.964 for RIA with SN and ELISA, respectively), RIA and ELISA proved to be at least 10 times more sensitive than neutralization tests. By using these techniques, it was possible to detect a time-dependent decrease in antibody levels in bovine colostrum after parturition. Using ELISA, we demonstrated that 12 of 12 herds in Saskatchewan, and 109 of 110 animals tested, and antibody to bovine coronavirus. There was no elevated antibody response in serum or lacteal secretions of cows vaccinated once or twice with a commercially available modified live rota-coronavirus vaccine. In addition to being more sensitive than SN, ELISA and RIA proved to have other advantages for measuring antibody levels to bovine coronavirus and therefore warrant wider use as tools in diagnostic virology.

  16. An enzyme-linked immunosorbent assay for the quantification of serum platelet-bindable IgG.

    Science.gov (United States)

    Howe, S E; Lynch, D M; Lynch, J M

    1984-01-01

    An enzyme-linked immunosorbent assay (ELISA) using F(ab')2 peroxidase-labeled antihuman immunoglobulin and o-phenylenediamine dihydrochloride (OPD) as a substrate was developed to measure serum platelet bindable IgG (S-PBIgG). The assay was made quantitative by standardizing the number of normal "target" platelets bound to microtiter plate wells, and by incorporating quantitated IgG standards with each microtiter plate tested to prepare a standard calibration curve. By this method, S-PBIgG for normal individuals was 3.4 +/- 1.6 fg per platelet (mean +/- 1 SD; n = 40). Increased S-PBIgG levels were detected in 36 of 40 patients with clinical autoimmune thrombocytopenia (ATP), ranging from 7.0 to 85 fg per platelet. Normal S-PBIgG levels were found in 34 of 40 patients with nonimmune thrombocytopenia. This method showed a sensitivity of 90 percent, specificity of 85 percent, and in the sample population studied, a positive predictive value of 0.86 and a negative predictive value of 0.90. This assay is highly reproducible (coefficient of variation was 6.8%) and appears useful in the evaluation of patients with suspected immune-mediated thrombocytopenia.

  17. Diagnosis of selected tropical diseases (Shistosomiasis and Malaria) using the enzyme-linked immunosorbent assays

    International Nuclear Information System (INIS)

    Chembe, E.

    1985-01-01

    Immunological reactions are commonly used in diagnostic procedures on the basis of their high levels of specificity and sensitivity. Antibodies or antigens labelled with various markers have been found to be particularly useful for assays of logical substances. The applications of Enzyme-Linked Immunoabsorbent Assays (ELISA) to research on various tropical and non-tropical diseases is now well established. The procedure depends on the labelling of one of the reactants with enzymes which can be detected accurately by an appropriate substrate. The detection mechanism depends on the labelling of one of the reactants in such a way that their their reactivity is not impaired or affected. In the present study, ELISA was applied to sera from kampumbu area of Isoka district in the Northern province of Zambia. The objective of this presentation is to show the relative positivity rate for antigen and antibody and the endemicity of schistosomiasis and malaria as assessed by classical parasitological procedures. (author)

  18. Evaluation of some magnetizable immunosorbents in radioimmunoassays and immunoradiometric assays of hormones

    International Nuclear Information System (INIS)

    Jyotsna, N.; Kadwad, V.; Sivaprasad, N.; Nirmala, V.; Pal, N.; Singh, Y.; Karir, T.; Chouthkantiwar, V.; Paradkar, S.

    1996-01-01

    Immunoassays are now indispensable clinical tools in many laboratories. An essential requirement for achieving reliable assays is an efficient and clean method for separating the immune complexes from the unreacted reagents. The development of a wide variety of solid phase separation methods has contributed significantly towards the reliability and simplification of immunoassays. Antibody coated macro one-piece surfaces like plastic beads or tubes are very popular but require great skill and control at all stages of manufacture. On the other hand, finely divided supports especially magnetizable particles are cheaper and simpler to develop. A variety of materials have been used in immunoassays. Black iron oxide Fe 3 O 4 is the most commonly used material and it is generally coated with polymeric materials like polymerized alkyl silanes, m-diaminobenzene, polyacrylamide, polyacrolein, or cellulose to facilitate covalent coupling of the antibodies. In this project we have evaluated some magnetizable particles for use in RIAs and IRMAs of hormones. The particles include Fe 3 0 4 , silane coated iron oxide, polyacrolein coated iron oxide and magnetizable cellulose. Second antibody (anti rabbit IgG.) was coupled to the particles for use in RIA of T 3 , T 4 , HCG, LH and progesterone, while monoclonal antibodies were coupled for the IRMAs of TSH, FSH and prolactin (hPrl). The influence of conditions such as reaction time, ratio of antibody to particles, and stability of the adsorbents and assay performance have been studied. For developing IRMAs for TSH, FSH and prolactin, monoclonal antibodies for each of these hormones were tested using magnetizable cellulose as the solid phase. We have also prepared silanized Fe 3 0 4 particles using Hungarian magnetite particles, and also prepared magnetizable cellulose by a simple grinding process. Both these materials are being tried out in different assays. Preliminary results have been encouraging. (author). 7 refs, 3 figs, 9 tabs

  19. Use of hydrophilic extra-viral domain of canine distemper virus H protein for enzyme-linked immunosorbent assay development.

    Science.gov (United States)

    Cho, Ki-hyun; Kim, Jeongmi; Yoo, Hyun-ah; Kim, Dae-hee; Park, Seung-yong; Song, Chang-seon; Choi, In-soo; Lee, Joong-bok

    2014-12-01

    Simple methods for measuring the levels of serum antibody against canine distemper virus (CDV) would assist in the effective vaccination of dogs. To develop an enzyme-linked immunosorbent assay (ELISA) specific for CDV, we expressed hydrophilic extra-viral domain (HEVD) protein of the A75/17-CDV H gene in a pET 28a plasmid-based Escherichia (E.) coli vector system. Expression was confirmed by dot and Western blotting. We proposed that detection of E. coli-expressed H protein might be conformation- dependent because intensities of the reactions observed with these two methods varied. The H gene HEVD protein was further purified and used as an antigen for an ELISA. Samples from dogs with undetectable to high anti-CDV antibody titers were analyzed using this HEVD-specific ELISA and a commercial CDV antibody detection kit (ImmunoComb). Levels of HEVD antigenicity measured with the assays and immunochromatography correlated. These data indicated that the HEDV protein may be used as antigen to develop techniques for detecting antibodies against CDV.

  20. Development of an enzyme-linked immunosorbent assay for residue analysis of the insecticide emamectin benzoate in agricultural products.

    Science.gov (United States)

    Kondo, Mika; Yamashita, Hiroshi; Uchigashima, Mikiko; Kono, Takeshi; Takemoto, Toshihide; Fujita, Masahiro; Saka, Machiko; Iwasa, Seiji; Ito, Shigekazu; Miyake, Shiro

    2009-01-28

    A direct competitive enzyme-linked immunosorbent assay (dc-ELISA) for the analysis of emamectin residues in agricultural products was developed using a prepared mouse monoclonal antibody. The working range was 0.3-3.0 ng/mL, and the 50% inhibition concentration (IC(50)) was 1.0 ng/mL. The assay was sufficiently sensitive for analysis of the maximum residue limits in agricultural products in Japan (>0.1 microg/g). Emamectin residues contain the following metabolites: the 4''-epi-amino analogue, the 4''-epi-(N-formyl)amino analogue, the 4''-epi-(N-formyl-N-methyl)amino analogue, and the 8,9-Z isomer. The dc-ELISA reacted with these compounds at ratios of 113, 55, 38, and 9.1% of the IC(50) value of emamectin benzoate. Seven kinds of vegetables were spiked with emamectin benzoate at concentrations of 15-300 ng/g, and the recoveries were 91-117% in the dc-ELISA. The dc-ELISA results agreed reasonably well with results obtained by liquid chromatography-tandem mass spectrometry (LC-MS/MS) using spiked samples and actual (incurred) samples. The results indicate that the dc-ELISA was useful for the analysis of emamectin benzoate residues in agricultural products.

  1. Enzyme linked immunosorbent assay for detecting antibody to Trichomonas vaginalis: use of whole cells and aqueous extract as antigen.

    Science.gov (United States)

    Alderete, J F

    1984-06-01

    An enzyme linked immunosorbent assay (ELISA) for detecting antibody to antigenic Trichomonas vaginalis macromolecules has been identified using whole cells or an aqueous protein extract as antigen. The test was developed under optimum conditions using serum samples from experimental animals. The sensitivity of the ELISA was equal to or greater than that obtained by radioimmunoprecipitation and electrophoresis-fluorography techniques. The ELISA was capable of assessing antibody responses during the development of lesions in animals inoculated subcutaneously and it reproducibly measured the individual classes immunoglobulins directed at T vaginalis. The colorimetric assay was also suitable for showing cross reactivity between trichomonal species as well as between different strains of T vaginalis. Conditions established for monitoring antibody to trichomanads in immunised rabbits or infected mice were equally effective for human materials, such as serum or vaginal washes. Serum from experimental animals or infected people showed high concentrations of IgG, IgA, and IgM antibody to trichomonads. Only antibodies of the IgG and IgA class were detected in vaginal washes from women with acute trichomoniasis. No IgE antibody to trichomonads was found under a variety of conditions in serum samples from patients or experimental animals.

  2. Field assessment of the enzyme linked immunosorbent assay for foot-and-mouth disease virus diagnosis and typing

    International Nuclear Information System (INIS)

    Smitsaart, E.; Fondevila, N.; Compaired, D.; Maradei, E.; Fernandez, E.

    1998-01-01

    The objective of the present study was to evaluate the enzyme linked immunosorbent assay (ELISA) in comparison with the complement fixation test (CFT) for the diagnosis and typing of foot-and-mouth disease (FMD) virus (FMDV). Diagnostic material was epithelium from either suspected cases of FMD or from animals experimentally infected with FMDV. Epithelial suspensions and supernatant fluids from cell culture passage were assayed by CFT and ELISA. The superiority of the ELISA over the CFT was demonstrated: 1) the detection rate was 23% higher than that of CFT on original (epithelial) suspensions (OS) submissions of all sample (positive and negative) and 30% higher on supernatant fluids from cell culture passage, 2) the detection rate of ELISA on OS of confirmed positive samples was 28% higher than that of CFT, 3) no significant differences were observed in the detection and typing rates between the PANAFTOSA and FAO/IAEA ELISA kits (P<0.05) and 4) the sensitivity of the ELISA was 16 to 85 times higher than that of CFT when serial dilutions of sample homogenates were examined. (author)

  3. Comparison of enzyme-linked immunosorbent assay and rapid chemiluminescent analyser in the detection of myeloperoxidase and proteinase 3 autoantibodies.

    Science.gov (United States)

    Pucar, Phillippa A; Hawkins, Carolyn A; Randall, Katrina L; Li, Candice; McNaughton, Euan; Cook, Matthew C

    2017-06-01

    Antibodies to myeloperoxidase (MPO) and proteinase 3 (PR3) are vital in the diagnosis and management of ANCA-associated vasculitis. A chemiluminescent immunoassay (CLIA; Quanta Flash) provides MPO and PR3 antibody results in 30 minutes, which is much faster than enzyme-linked immunosorbent assay (ELISA). We compared the performance of ELISA (Orgentec) and CLIA (Quanta Flash) for MPO and PR3 antibody quantitation on 303 samples, comprising 196 consecutive samples received in a single diagnostic laboratory over a 3 month period, and 107 samples collected from 42 known vasculitis patients over a 40 month period. We observed a correlation between both methods using spearman correlation coefficients (MPO, r s  = 0.63, p assays) and disease relapse (correlation for both MPO and PR3 antibody quantitation r s  = 0.84, p = 0.03 and r s  = 0.78, p ELISA for measurement of MPO and PR3 antibodies. Copyright © 2017. Published by Elsevier B.V.

  4. Determination of the folate content in cladodes of nopal (Opuntia ficus indica) by microbiological assay utilizing Lactobacillus casei (ATCC 7469) and enzyme-linked immunosorbent assay.

    Science.gov (United States)

    Ortiz-Escobar, Tania Breshkovskaya; Valverde-González, Maria Elena; Paredes-López, Octavio

    2010-05-26

    Prickly pear cactus has been an important food source in Mexico since ancient times due to its economical and ecological benefits and potential nutraceutical value. Nevertheless, studies on the nutritional aspects and health benefits have been scarce. The purpose of this study was to assess, apparently for the first time, the folate contents of cladodes of nopal by a microbiological assay, using Lactobacillus casei (ATCC 7469) in extracts that were enzymatically treated to release the bound vitamin, employing single, dual, and trienzymatic procedures, and using the enzyme-linked immunosorbent assay (ELISA). We used Opuntia cladodes of different length sizes. The microbiological assay showed some differences among enzyme treatments and sizes of nopal; the trienzyme treatment (alpha-amylase-protease-conjugase) was more efficient in determining the folate content in nopal, giving 5.0 ng/g in the small size cladodes at 54 h of testing time, while ELISA showed no significant differences in the folate content among sizes of cladodes (5.5-5.62 ng/g at 0 min testing time). Both techniques may be used for the assessment of folate content in cladodes, but ELISA is more rapid and reliable.

  5. The use of enzyme-linked immunosorbent assay systems for the serology and antigen detection in parvovirus, coronavirus and rotavirus infections in dogs in The Netherlands.

    NARCIS (Netherlands)

    G.F. Rimmelzwaan (Guus); J. Groen (Jan); H.F. Egberink (Herman); G.H.A. Borst (Gerrit); F.G.C.M. Uytdehaag (Fons); A.D.M.E. Osterhaus (Albert)

    1991-01-01

    textabstractComplex trapping blocking (CTB) enzyme-linked immunosorbent assays (ELISAs) and indirect ELISAs for the detection of antibodies to canine parvovirus (CPV), canine coronavirus (CCV) and rotavirus in sera of dogs were established. Double antibody sandwich ELISAs for the detection of CPV-,

  6. Evaluation of enzyme-linked immunosorbent assays based on monoclonal antibodies for the serology and antigen detection in canine parvovirus infections.

    NARCIS (Netherlands)

    G.F. Rimmelzwaan (Guus); N. Juntti; B. Klingeborn; J. Groen (Jan); F.G.C.M. Uytdehaag (Fons); A.D.M.E. Osterhaus (Albert)

    1990-01-01

    textabstractAn enzyme-linked immunosorbent assay (ELISA) system was developed for the detection of canine parvovirus (CPV) or CPV antigen in dog faeces and two other ELISA systems were developed for the detection of CPV-specific antibodies in dog sera. The ELISA's were based on the use of

  7. Onderzoek naar toepasbaarheid van Enzyme-Linked Immunosorbent Assay (ELISA) voor het bepalen van aflatoxinen in voedings- en voedermiddelen 1e interimrapport: Orientatie en taakstelling

    NARCIS (Netherlands)

    Egmond; H.P. van; Paulsch; W.E.; Sizoo; E.A.

    1987-01-01

    Immunochemische methoden van onderzoek voor het bepalen van mycotoxinen komen langzamerhand in de belangstelling te staan, vooral Enzyme-Linked Immunosorbent Assay (ELISA). Om een beeld te krijgen van de praktische en wetenschappelijke karakteristieken van ELISA's in het

  8. Challenges for bovine viral diarrhoea virus antibody detection in bulk milk by antibody enzyme-linked immunosorbent assays due to changes in milk production levels

    DEFF Research Database (Denmark)

    Foddai, Alessandro; Enøe, Claes; Stockmarr, Anders

    2015-01-01

    Background: Bovine viral diarrhoea (BVD) is considered eradicated from Denmark. Currently, very few (if any) Danish cattle herds could be infected with BVD virus (BVDV). The Danish antibody blocking enzyme-linked immunosorbent assay (ELISA) has been successfully used during the Danish BVD eradica...

  9. AN ENZYME LINKED IMMUNOSORBENT ASSAY (ELISA) METHOD FOR THE URINARY BIOMONITORING OF 2,4-DICHLOROPHRENOCYACETIC ACID (2,4-D)

    Science.gov (United States)

    An enzyme-linked immunosorbent assay (ELISA) method was developed to quantitatively measure 2,4-dichlorophenoyacetic acid (2,4-D) in human urine. Samples were diluted (1:5) with phosphate-buffered saline, 0.05% Tween 20, with 0.02% sodium azide, and analyzed by a 96-microwekk pl...

  10. Comparison of an enzyme linked immunosorbent assay (ELISA) and a radioallergosorbent test (RAST) for detection of IgE antibodies to Brugia malayi

    NARCIS (Netherlands)

    Wahyuni, Sitti; van Ree, Ronald; Mangali, Andarias; Supali, Taniawati; Yazdanbakhsh, Maria; Sartono, Erliyani

    2003-01-01

    The enzyme linked immunosorbent assay (ELISA) for specific IgE antibodies to Brugia malayi was compared with the radioallergosorbent test (RAST) for use in immunoepidemiological studies of lymphatic filariasis. Sera used were from individuals (aged 5-82 years) living in an area endemic for lymphatic

  11. Development and validation of an indirect Enzyme-linked Immunosorbent Assay for the detection of antibodies against Schmallenberg virus in blood samples from ruminants

    NARCIS (Netherlands)

    Heijden, van der H.M.J.F.; Bouwstra, R.J.; Mars, M.H.; Poel, van der W.H.M.; Wellenberg, G.J.; Maanen, van C.

    2013-01-01

    To detect Schmallenberg virus (SBV) infections in ruminants and to perform SBV epidemiological studies a cost-effective serological test is required. For these purposes an indirect whole virus Enzyme-linked Immunosorbent Assay (ELISA) for detection of SBV specific antibodies in ruminant blood

  12. Evaluation of a commercial competitive enzyme-linked immunosorbent assay for detection of avian influenza virus subtype H5 antibodies in zoo birds

    DEFF Research Database (Denmark)

    Jensen, Trine Hammer; Andersen, Jannie Holmegaard; Hjulsager, Charlotte Kristiane

    2017-01-01

    The hemagglutination inhibition (HI) test is the current gold standard for detecting antibodies to avian influenza virus (AIV). Enzyme-linked immunosorbent assays (ELISAs) have been explored for use in poultry and certain wild bird species because of high efficiency and lower cost. This study com...

  13. Low sensitivity of type VII collagen enzyme-linked immunosorbent assay in epidermolysis bullosa acquisita : serration pattern analysis on skin biopsy is required for diagnosis

    NARCIS (Netherlands)

    Terra, J. B.; Jonkman, M. F.; Diercks, G. F. H.; Pas, H. H.

    BackgroundThe type VII collagen (coll VII) enzyme-linked immunosorbent assay (ELISA) has been reported to have high sensitivity (>93%) and specificity (>96%) for diagnosing epidermolysis bullosa acquisita (EBA) in patients who are seropositive on indirect immunofluorescence on salt-split skin (SSS).

  14. SERO-DIAGNOSIS OF TUBERCULOSIS WITH A60 ANTIGEN ENZYME-LINKED-IMMUNOSORBENT-ASSAY - FAILURE IN HIV-INFECTED INDIVIDUALS IN GHANA

    NARCIS (Netherlands)

    VANDERWERF, TS; DAS, PK; VANSOOLINGEN, D; YONG, S; VANDERMARK, TW

    In order to assess the diagnostic usefulness of the A60 (ANDA Biologicals, Strassbourg, France) sero-diagnostic enzyme-linked immunosorbent assay (ELISA) kit for tuberculosis in Africa, sera of 53 pulmonary smear-positive tuberculosis (TB) patients, 30 apparently healthy control subjects and 6 AIDS

  15. Enzyme-Linked Immunosorbent Assay To Differentiate the Antibody Responses of Animals Infected with Brucella Species from Those of Animals Infected with Yersinia enterocolitica O9

    OpenAIRE

    Erdenebaatar, Janchivdorj; Bayarsaikhan, Balgan; Watarai, Masahisa; Makino, Sou-ichi; Shirahata, Toshikazu

    2003-01-01

    Enzyme-linked immunosorbent assays using antigens extracted from Brucella abortus with n-lauroylsarcosine differentiated natural Brucella-infected animals from Brucella-vaccinated or Yersinia enterocolitica O9-infected animals. A field trial in Mongolia showed cattle, sheep, goat, reindeer, camel, and human sera without infection could be distinguished from Brucella-infected animals by conventional serological tests.

  16. Evaluation of a competitive enzyme-linked immunosorbent assay for measurements of soluble HLA-G protein.

    Science.gov (United States)

    Rasmussen, M; Dahl, M; Buus, S; Djurisic, S; Ohlsson, J; Hviid, T V F

    2014-08-01

    The human leukocyte antigen (HLA) class Ib molecule, HLA-G, has gained increased attention because of its assumed important role in immune regulation. The HLA-G protein exists in several soluble isoforms. Most important are the actively secreted HLA-G5 full-length isoform generated by alternative splicing retaining intron 4 with a premature stop codon, and the cleavage of full-length membrane-bound HLA-G1 from the cell surface, so-called soluble HLA-G1 (sHLA-G1). A specific and sensitive immunoassay for measurements of soluble HLA-G is mandatory for conceivable routine testing and research projects. We report a novel method, a competitive immunoassay, for measuring HLA-G5/sHLA-G1 in biological fluids. The sHLA-G immunoassay is based upon a competitive enzyme-linked immunosorbent assay (ELISA) principle. It includes a recombinant sHLA-G1 protein in complex with β2-microglobulin and a peptide as a standard, biotinylated recombinant sHLA-G1 as an indicator, and the MEM-G/9 anti-HLA-G monoclonal antibody (mAb) as the capture antibody. The specificity and sensitivity of the assay were evaluated. Testing with different recombinant HLA class I proteins and different anti-HLA class I mAbs showed that the sHLA-G immunoassay was highly specific. Optimal combinations of competitor sHLA-G1 and capture mAb concentrations were determined. Two versions of the assay were tested. One with a relatively wide dynamic range from 3.1 to 100.0 ng/ml, and another more sensitive version ranging from 1.6 to 12.5 ng/ml. An intra-assay coefficient of variation (CV) of 15.5% at 88 ng/ml and an inter-assay CV of 23.1% at 39 ng/ml were determined. An assay based on the competitive sHLA-G ELISA may be important for measurements of sHLA-G proteins in several conditions: assisted reproduction, organ transplantation, cancer, and certain pregnancy complications, both in research studies and possibly in the future also for clinical routine use. © 2014 John Wiley & Sons A/S. Published by John Wiley

  17. Development and validation of an enzyme-linked immunosorbent assay for antibodies against Mycobacterium bovis in european wild boar

    Directory of Open Access Journals (Sweden)

    Gortázar Christian

    2008-11-01

    Full Text Available Abstract Background Bovine tuberculosis (bTB remains a significant problem in some parts of Spain largely because of contacts between cattle and wildlife reservoirs in extensive grazing systems. European Wild boar (Sus scrofa is one of the species involved in the transmission of the disease to other species. Fast and simple detection methods would be critical for assessing infection prevalence, study the mechanisms of pathogen transmission and monitoring the effects of TB control measures. Results An enzyme-linked immunosorbent assay (ELISA to detect antibodies against Mycobacterium bovis in wild boar serum was developed and validated on 185 sera from TB positive and negative wild boar. Based on antigen inoculation of captive animals as well as tuberculosis compatible lesions, culture results and molecular analysis of hunted individuals, animals were allocated into two groups: tuberculosis positive group and tuberculosis negative group. After optimization of the positive to negative ratio using different combinations of serum dilutions and conjugate concentrations, the test yielded a sensitivity of 72.60% and a specificity of 96.43% for the best cut-off. Conclusion Although some negative group animals showed an ELISA positive reaction (

  18. Evaluation of an enzyme linked immunosorbent assay kit for the detection of Babesia bovis antibodies in cattle in Argentina

    Energy Technology Data Exchange (ETDEWEB)

    Echaide, S; Echaide, I E; Mangold, A J; Lugaresi, C I; Guglielmone, A A [Estacion Experimental Agropecuaria, Instituto Nacional de Tecnologia Agropecuaria, Rafaela, Santa Fe (Argentina); Gaido, A B [Estacion Experimental Agropecuaria Salta, Salta (Argentina)

    1998-11-01

    An enzyme linked immunosorbent assay (ELISA) for the detection of antibodies to Babesia bovis was evaluated by using sera of 874 cattle carrying B. bovis antibodies, 700 sera of uninfected cattle, and 357 sera from calves from 16 herds subjected to different B. bovis inoculation rates. The seropositive/ seronegative cut-off point set as double the mean percent positivity of negative cattle sera (= 16%). The sensitivity of the ELISA (four trials) ranged from 97.1% to 100% and the specificity (three trials) varied from 92.0% to 97.0%. The agreement between ELISA and immunofluorescent antibody test was {>=} 90.0% in 18 of 23 evaluations and it ranged from 86.0% to 88.0% in the remainder. The correlation coefficient between percentage of sera positive to ELISA and IFA test in 16 herds was 0.9958 (P<0.001). The ELISA has the advantages of a high sensitivity, objectivity and capacity to test large number of samples in short period of time and could replace the IFA test specially for epidemiological studies. (author) 11 refs, 1 fig., 2 tabs

  19. Novel indirect enzyme-linked immunosorbent assay (ELISA) method to detect Total E. coli in water environment

    International Nuclear Information System (INIS)

    Wang Na; He Miao; Shi Hanchang

    2007-01-01

    In order to establish ELISA (enzyme-linked immunosorbent assay) method to detect Total E. coli in water environment, E. coli multi-characters antigens in water environment were prepared according to the characters of kinds of E. coli serotypes, including antigen of whole cell, antigen of disrupted whole cell, somatic antigen, flagellar antigen and fimbrial antigen. Total E. coli polyclonal antibodies were obtained from the New Zealand rabbits immunized with these five antigens, respectively. Antibodies generated in this research are with high titers and good purity, can conjugate with antigens, specifically, stably and strongly. Indirect ELISA shows the titers of antibody of whole cell and antibody of disrupted whole cell are both over 1 x 10 5 . The cross-reactivity of the antibody is from 12 to 30% which indicate the specificity of the antibody against Total E. coli. Based on these antibodies, we established indirect ELISA method to detect Total E. coli in water environment. The matrix effects were studied and the results show that there is no significant influence by all the factors. The ELISA result shows that the detection limitation could be 10 4 CFU (colony forming units) L -1 . The indirect ELISA method developed in this study is well suited for Total E. coli analysis in real water samples as a rapid screen method

  20. Identification of Proteinaceous Binders in Ancient Tripitaka by the Use of an Enzyme-linked Immunosorbent Assay.

    Science.gov (United States)

    Liu, Yi; Li, Yi; Chang, Runxing; Zheng, Hailing; Li, Menglu; Hu, Zhiwen; Zhou, Yang; Wang, Bing

    2016-01-01

    Proteinaceous materials, such as ovabumin and collagen, were commonly used as binding media, and as adhesives and protective coatings. However, the identification of ancient proteinaceous binders is a great challenge for archaeologists, due to their limited sample size, complex combinations of various ingredients and reduced availability of the binder during the process of protein degradation. In this paper, an enzyme-linked immunosorbent assay (ELISA) provides to be a particularly promising method for the detection of proteinaceous binding materials in ancient relics. The present work focused on the specific identification of proteins in archaeological binders, which was brushed on the Tripitaka. Two samples, the adhesion area (S1) and the ink area (S2), were tested by ELISA. The results showed that both S1 and S2 reacted positively when treated with an anti-collagen-I antibody. It proved the existence of proteinaceous binders in Ancient Tripitaka, and the percentage of collagen in S1 and S2 was 61.44 and 15.4%, respectively. Compared with other conventional techniques, ELISA has advantages of high specificity, sensitivity, rapidity and low cost, making it especially suitable for the protein detection in the archaeological field.

  1. Comparison of agar gel immunodiffusion test, enzyme-linked immunosorbent assay and PCR in diagnostics of enzootic bovine leukosis

    Directory of Open Access Journals (Sweden)

    Malovrh Tadej

    2005-01-01

    Full Text Available Bovine leukaemia virus (BLV is a retrovirus that induces a chronic infection in cattle. Once infected, cattle remain virus carriers for life and start to show an antibody response within a few weeks after infection. Eradication and control of the disease are based on early diagnostics and segregation of the carriers. The choice of a diagnostic method depends on the eradication programme, money resources and characteristics of the herd to be analysed. The agar gel immunodiffusion (AGID test has been the serological test of choice for routine diagnosis of serum samples. Nevertheless, in more recent years, the enzyme-linked immunosorbent assay (ELISA has replaced the AGID for large scale testing. For this purpose, commercially available BLV-ELISA kits were compared to the AGID and to the polymerase chain reaction (PCR method performed with two sets of primers, amplifying env region. The ELISA kit based on the p24 core protein was found to be less specific and served as a screening test. The ELISA kit based on the envelope glycoprotein (gpSI served as a verification test and gave a good correlation with the AGID test and PCR method. However, ELISA showed a higher sensitivity than AGID. The p24 based ELiSA was useful for screening a large number of samples, whereas gp51 based ELISA, AGID and PCR were more important for detecting the antibody response against the individual BLV-proteins and therefore for verification of the infection with BLV.

  2. Identification of phlebotomine sandfly bloodmeals from Baringo District, Kenya, by direct enzyme-linked immunosorbent assay (ELISA).

    Science.gov (United States)

    Ngumbi, P M; Lawyer, P G; Johnson, R N; Kiilu, G; Asiago, C

    1992-10-01

    Direct enzyme-linked immunosorbent assay (ELISA) was used to identify the sources of bloodmeals in phlebotomine sandflies from Baringo District, Rift Valley Province, Kenya. Some bloodmeals had been stored for over 4 years before being analysed. Among 356 sandflies identified, 62.9% were Phlebotomus martini, 14.8% Sergentomyia antennatus, 10% S.schwetzi, 6% S.clydei, 1.9% S.adleri, 1.6% P.duboscqi, 1.4% S.africanus and 0.8% S.bedfordi. Out of 224 P.martini bloodmeals, host source was identified for 69. The order of host preference for P.martini was: goat 28.5%, rabbit 22.7%, human 8.9% and others 8.9%. Evidence of mixed feeding was shown by four species comprising sixteen specimens, twelve of which were P.martini. The most effective methods for trapping bloodfed P. martini were sticky paper traps in termite hills, followed by light-traps. Of the 224 P.martini trapped, 58.9% were collected with traps in termite hills, and 22.7% with light traps. Roles of the three most popular hosts for P.martini should be investigated to ascertain whether they act as reservoirs in the transmission of Leishmania donovani causing visceral leishmaniasis in Kenya.

  3. Parameters for measurement of oxidative stress in diabetes mellitus: applicability of enzyme-linked immunosorbent assay for clinical evaluation.

    Science.gov (United States)

    Noiri, Eisei; Tsukahara, Hirokazu

    2005-05-01

    Investigations of the mechanisms involved in the onset and progression of diabetes have recently confronted the role of reactive oxygen species (ROS) and oxidative stress. Prolonged exposure to hyperglycemic conditions induces nonenzymatic glycation of protein via the so-called Maillard reaction, resulting in Schiff-base products and Amadori products that engender ROS production. These processes initiate and exacerbate micro- and macrovascular complications in diabetes. Increased oxidative stress is induced by excessive ROS production and inadequate antioxidant defenses. Recently, oxidative stress status markers have been associated directly with the severity and prognosis of diabetes. To examine oxidative stress, reliable and high-throughput methods are needed to examine large numbers of clinical samples. The emerging availability of enzyme-linked immunosorbent assay (ELISA) for oxidative stress status markers allows its application to assessment of various pathophysiologic conditions, including diabetes. This review outlines the recent achievements of ELISA application for clinical studies elucidating oxidative stress. It introduces the potential applicability of ELISA for investigating oxidative stress in diabetes.

  4. ENZYME-LINKED IMMUNOSORBENT ASSAY FOR SCREENING DIOXIN SOIL CONTAMINATION BY UNCONTROLLED COMBUSTION DURING INFORMAL RECYCLING IN SLUMS

    Science.gov (United States)

    Trindade, Mirta; Nording, Malin; Nichkova, Mikaela; Spinnel, Erik; Haglund, Peter; Last, Michael S.; Gee, Shirley; Hammock, Bruce; Last, Jerold A.; González-Sapienza, Gualberto; Brena, Beatriz M.

    2010-01-01

    Uncontrolled combustion due to garbage recycling is a widespread activity among slum dwellers in distressed economy countries and has been indicated as a major source of dioxin contamination. However, because of the high cost and complexity of gas chromatography/high-resolution mass spectrometry (GC-HRMS) analysis, the magnitude of the problem remains largely unknown. The present study describes a first approach toward the use of a dioxin antibody-based enzyme-linked immunosorbent assay (ELISA) as the basis for a sustainable, simple, and low-cost monitoring program to assess the toxicological impact of uncontrolled combustion in slums. A panel of 16 samples was analyzed by GC-HRMS and ELISA on split extracts. Close to 20% of the analyzed samples showed dioxin concentrations up to almost twice the guidance level for residential soil in several countries, pointing out the need for performing a large-scale monitoring program. Despite the potential for variations in dioxin congener distribution due to the mixed nature of the incinerated material, there was a good correlation between the toxic equivalents as determined by GC-HRMS and ELISA. Furthermore, an interlaboratory ELISA validation showed that the capacity to perform the dioxin ELISA was successfully transferred between laboratories. It was concluded that the ELISA method performed very well as a screening tool to prioritize samples for instrumental analysis, which allows cutting down costs significantly. PMID:18522475

  5. Comparative analysis of enzyme-linked immunosorbent assay and direct microscopy for the diagnosis of Giardia intestinalis in fecal samples

    Directory of Open Access Journals (Sweden)

    Shipra Singhal

    2015-01-01

    Full Text Available Context: Giardiasis is one of the most common nonviral infections causing diarrheal illness worldwide. In this prospective cross-sectional study, we evaluated the RIDASCREEN ® Giardia kit for detection of Giardia intestinalis in stool samples and compared the results with direct microscopy. Materials and methods: A total of 360 fecal samples were collected. They were then processed by wet film, iodine preparation and an enzyme-linked immunosorbent assay (ELISA kit to determine the presence of Giardia trophozoites and cysts. Statistical analysis was performed by sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy. Results and Conclusion: Of the 360 cases, 17.2% samples were positive for Giardia by direct microscopy and 23.6% were found to be positive by ELISA (sensitivity ~97%, but specificity was ~92% only. Because of less specificity, we need to perform ELISA in congruence with direct microscopy, etc. Further studies need to be performed on a larger sample size using other molecular tests in order to get more accurate estimations.

  6. Detection of Giardia duodenalis antigen in human fecal eluates by enzyme-linked immunosorbent assay using polyclonal antibodies

    Directory of Open Access Journals (Sweden)

    Sofía Duque-Beltrán

    2002-12-01

    Full Text Available The present study developed and standardized an enzime-linked immunosorbent assay (ELISA to detect Giardia antigen in feces using rabbit polyclonal antibodies. Giardia cysts were purified from human fecal samples by sucrose and percoll gradients. Gerbils (Meriones unguiculatus were infected to obtain trophozoites. Rabbits were inoculated with either cyst or trophozoite antigens of 14 Colombian Giardia isolates to develop antibodies against the respective stages. The IgG anti-Giardia were purified by sequential caprylic acid and ammonium sulfate precipitation. A portion of these polyclonal antibodies was linked to alkaline phosphatase (conjugate. One hundred and ninety six samples of human feces, from different patients, were tested by parasitologic diagnosis: 69 were positive for Giardia cysts, 56 had no Giardia parasites, and 71 revealed parasites other than Giardia. The optimal concentration of polyclonal antibodies for antigen capture was 40 µg/ml and the optimal conjugate dilution was 1:100. The absorbance cut-off value was 0.24. The parameters of the ELISA test for Giardia antigen detection were: sensitivity, 100% (95% CI: 93.4-100%; specificity, 95% (95% CI: 88.6-97.6%; positive predictive value, 91% (95% CI: 81.4-95.9%; and negative predictive value, 100% (95% CI: 96.1-100%. This ELISA will improve the diagnosis of Giardia infections in Colombia and will be useful in following patients after treatment.

  7. Development of enzyme linked immunosorbent assay (ELISA) for the detection of root-knot nematode Meloidogyne incognita.

    Science.gov (United States)

    Kapur-Ghai, J; Kaur, M; Goel, P

    2014-09-01

    Root-knot nematodes (Meloidogyne incognita) are obligate, sedentary plant endoparasites that are extremely polyphagous in nature and cause severe economic losses in agriculture. Hence, it is essential to control the parasite at an early stage. For any control strategy to be effective, an early and accurate diagnosis is of paramount importance. Immunoassays have the inherent advantages of sensitivity and specificity; have the potential to identify and quantify these plant-parasitic nematodes. Hence, in the present studies, enzyme-linked immunosorbent assay (ELISA) has been developed for the detection of M.incognita antigens. First an indirect ELISA was developed for detection and titration of anti-M.incognita antibodies. Results indicated as high as 320 K titre of the antisera. Finally competitive inhibition ELISA was developed employing these anti-M.incognita antibodies for detection of M.incognita antigens. Sensitivity of ELISA was 10 fg. Competitive inhibition ELISA developed in the present studies has the potential of being used as an easy, rapid, specific and sensitive diagnostic tool for the detection of M.incognita infection.

  8. Improved quantification of a commercial enzyme-linked immunosorbent assay kit for measuring anti-MDA5 antibody.

    Science.gov (United States)

    Gono, Takahisa; Okazaki, Yuka; Murakami, Akihiro; Kuwana, Masataka

    2018-04-09

    To compare the quantitative performance for measuring anti-MDA5 antibody titer of two enzyme-linked immunosorbent assay (ELISA) systems: an in-house ELISA and the commercial MESACUP TM anti-MDA5 test. Anti-MDA5 antibody titer was measured in sera from 70 patients with dermatomyositis using an in-house ELISA and the MESACUP TM anti-MDA5 test side-by-side. For the commercial ELISA kit, serum samples diluted 1:101 were used according to the manufacturer's protocol, but serial dilutions of sera were also examined to identify the optimal serum dilution for quantification. The anti-MDA5 antibody titers measured by the in-house and commercial ELISAs were positively correlated with each other (r = 0.53, p = .0001), but the antibody titer measured by the commercial ELISA was less sensitive to change after medical treatment, and 37 (80%) of 46 anti-MDA5-positive sera had antibody titer exceeding the quantification range specified by the manufacturer (≥150 index). Experiments using diluted serum samples revealed that diluting the sera 1:5050 improved the quantitative performance of the MESACUP TM anti-MDA5 test, including a better correlation with the in-house ELISA results and an increased sensitivity to change. We improved the ability of the commercial ELISA kit to quantify anti-MDA5 antibody titer by altering its protocol.

  9. Sensitive radioimmunoassay and enzyme-linked immunosorbent assay for the simultaneous determination of chloroquine and its metabolites in biological fluids

    International Nuclear Information System (INIS)

    Escande, C.; Chevalier, P.; Verdier, F.; Bourdon, R.

    1990-01-01

    Two new methods for the simultaneous determination of chloroquine and its two main metabolites (monodesethylchloroquine and bisdesethylchloroquine) in biological samples, radioimmunoassay (RIA) and enzyme-linked immunosorbent assay (ELISA), are described. Antiserum is produced in rabbits immunized with N-(2-carboxyethyl)desethylchloroquine:protein conjugate. Besides chloroquine, this antiserum recognizes with good affinity the two main metabolites, monodesethylchloroquine and bisdesethylchloroquine (70 and 40% of crossreaction, respectively). Amodiaquine cross reacts by 4.5%; cross reactions with monodesethylamodiaquine, bisdesethylamodiaquine, and other antimalarial drugs are less than 1%. No extraction step or sample preparation is required for either system. Sensitivity limits are, respectively, 0.70 nM (3 pg of chloroquine sulfate measured in 10 microL of plasma sample) for RIA, and 10 nM (22 pg of chloroquine sulfate measured in 5 microL of plasma sample) for ELISA. The interassay coefficients of variation are, respectively, less than 10 and less than 16% for RIA and ELISA in the range 14-410 nM (6-180 ng/mL). The results of both methods are well correlated (r = 0.97) and correlate with spectrophotometry (r = 0.98) and HPLC results (r = 0.93). Because of their high sensitivity, both methods can be used in the case of chloroquine poisoning and in the control of malaria prophylaxis and treatment

  10. Commercial Milk Enzyme-Linked Immunosorbent Assay (ELISA) Kit Reactivities to Purified Milk Proteins and Milk-Derived Ingredients.

    Science.gov (United States)

    Ivens, Katherine O; Baumert, Joseph L; Taylor, Steve L

    2016-07-01

    Numerous commercial enzyme-linked immunosorbent assay (ELISA) kits exist to quantitatively detect bovine milk residues in foods. Milk contains many proteins that can serve as ELISA targets including caseins (α-, β-, or κ-casein) and whey proteins (α-lactalbumin or β-lactoglobulin). Nine commercially-available milk ELISA kits were selected to compare the specificity and sensitivity with 5 purified milk proteins and 3 milk-derived ingredients. All of the milk kits were capable of quantifying nonfat dry milk (NFDM), but did not necessarily detect all individual protein fractions. While milk-derived ingredients were detected by the kits, their quantitation may be inaccurate due to the use of different calibrators, reference materials, and antibodies in kit development. The establishment of a standard reference material for the calibration of milk ELISA kits is increasingly important. The appropriate selection and understanding of milk ELISA kits for food analysis is critical to accurate quantification of milk residues and informed risk management decisions. © 2016 Institute of Food Technologists®

  11. Evaluation of an enzyme linked immunosorbent assay kit for the detection of Babesia bovis antibodies in cattle in Argentina

    International Nuclear Information System (INIS)

    Echaide, S.; Echaide, I.E.; Mangold, A.J.; Lugaresi, C.I.; Guglielmone, A.A.; Gaido, A.B.

    1998-01-01

    An enzyme linked immunosorbent assay (ELISA) for the detection of antibodies to Babesia bovis was evaluated by using sera of 874 cattle carrying B. bovis antibodies, 700 sera of uninfected cattle, and 357 sera from calves from 16 herds subjected to different B. bovis inoculation rates. The seropositive/ seronegative cut-off point set as double the mean percent positivity of negative cattle sera (= 16%). The sensitivity of the ELISA (four trials) ranged from 97.1% to 100% and the specificity (three trials) varied from 92.0% to 97.0%. The agreement between ELISA and immunofluorescent antibody test was ≥ 90.0% in 18 of 23 evaluations and it ranged from 86.0% to 88.0% in the remainder. The correlation coefficient between percentage of sera positive to ELISA and IFA test in 16 herds was 0.9958 (P<0.001). The ELISA has the advantages of a high sensitivity, objectivity and capacity to test large number of samples in short period of time and could replace the IFA test specially for epidemiological studies. (author)

  12. Dual-color plasmonic enzyme-linked immunosorbent assay based on enzyme-mediated etching of Au nanoparticles

    Science.gov (United States)

    Guo, Longhua; Xu, Shaohua; Ma, Xiaoming; Qiu, Bin; Lin, Zhenyu; Chen, Guonan

    2016-09-01

    Colorimetric enzyme-linked immunosorbent assay utilizing 3‧-3-5‧-5-tetramethylbenzidine(TMB) as the chromogenic substrate has been widely used in the hospital for the detection of all kinds of disease biomarkers. Herein, we demonstrate a strategy to change this single-color display into dual-color responses to improve the accuracy of visual inspection. Our investigation firstly reveals that oxidation state of 3‧-3-5‧-5-tetramethylbenzidine (TMB2+) can quantitatively etch gold nanoparticles. Therefore, the incorporation of gold nanoparticles into a commercial TMB-based ELISA kit could generate dual-color responses: the solution color varied gradually from wine red (absorption peak located at ~530 nm) to colorless, and then from colorless to yellow (absorption peak located at ~450 nm) with the increase amount of targets. These dual-color responses effectively improved the sensitivity as well as the accuracy of visual inspection. For example, the proposed dual-color plasmonic ELISA is demonstrated for the detection of prostate-specific antigen (PSA) in human serum with a visual limit of detection (LOD) as low as 0.0093 ng/mL.

  13. The development of an enzyme-linked immunosorbent assay for Trypanosoma vivax antibodies and its use in epidemiological surveys

    Directory of Open Access Journals (Sweden)

    Claudio R Madruga

    2006-11-01

    Full Text Available There are data indicating that the distribution of Trypanosoma vivax in the Brazilian territory is expanding with potential to reach other areas, where the vectors are present. The detection of anti-trypanosomal antibodies in serum provides important information of the trypanosomal status in cattle herds. For this reason, an enzyme-linked immunosorbent assay (Tv-ELISA-Ab with crude antigen from one Brazilian isolate of T. vivax was developed and evaluated. The sensitivity and specificity were respectively 97.6 and 96.9%. In the evaluation of cross-reactions, three calves inoculated with T. evansi trypimastigotes blood forms showed optical densities (OD under the cut-off during the whole experimental period, except one at 45 days post-inoculation. With relation to Babesia bovis, B. bigemina, and Anaplasma marginale, which are endemic hemoparasites in the studied area, the cross-reactions were shown to be 5.7, 5.3, and 1.1%, respectively. The first serological survey of Pantanal and state of Pará showed that T. vivax is widespread, although regions within both areas had significantly different prevalences. Therefore, this Tv-ELISA-Ab may be a more appropriate test for epidemiological studies in developing countries because the diagnostic laboratories in most countries may be able to perform an ELISA, which is not true for polymerase chain reaction.

  14. Microbubble Enzyme-Linked Immunosorbent Assay for the Detection of Targeted Microbubbles in in Vitro Static Binding Assays.

    Science.gov (United States)

    Wischhusen, Jennifer; Padilla, Frederic

    2017-07-01

    Targeted microbubbles (MBs) are ultrasound contrast agents that are functionalized with a ligand for ultrasound molecular imaging of endothelial markers. Novel targeted MBs are characterized in vitro by incubation in protein-coated wells, followed by binding quantification by microscopy or ultrasound imaging. Both methods provide operator-dependent results: Between 3 and 20 fields of view from a heterogeneous sample are typically selected for analysis by microscopy, and in ultrasound imaging, different acoustic settings affect signal intensities. This study proposes a new method to reproducibly quantify MB binding based on enzyme-linked immunosorbent assay (ELISA), in which bound MBs are revealed with an enzyme-linked antibody. MB-ELISA was adapted to in vitro static binding assays, incubating the MBs in inverted position or by agitation, and compared with microscopy. The specificity and sensitivity of MB-ELISA enable the reliable quantification of MB binding in a rapid, high-throughput and whole-well analysis, facilitating the characterization of new targeted contrast agents. Copyright © 2017 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  15. Comparison of four functionalization methods of gold nanoparticles for enhancing the enzyme-linked immunosorbent assay (ELISA

    Directory of Open Access Journals (Sweden)

    Paula Ciaurriz

    2017-01-01

    Full Text Available The enzyme-linked immunosorbent assay (ELISA technique is based on the specific recognition ability of the molecular structure of an antigen (epitope by an antibody and is likely the most important diagnostic technique used today in bioscience. With this methodology, it is possible to diagnose illness, allergies, alimentary fraud, and even to detect small molecules such as toxins, pesticides, heavy metals, etc. For this reason, any procedures that improve the detection limit, sensitivity or reduce the analysis time could have an important impact in several fields. In this respect, many methods have been developed for improving the technique, ranging from fluorescence substrates to methods for increasing the number of enzyme molecules involved in the detection such as the biotin–streptavidin method. In this context, nanotechnology has offered a significant number of proposed solutions, mainly based on the functionalization of nanoparticles from gold to carbon which could be used as antibody carriers as well as reporter enzymes like peroxidase. However, few works have focused on the study of best practices for nanoparticle functionalization for ELISA enhancement. In this work, we use 20 nm gold nanoparticles (AuNPs as a vehicle for secondary antibodies and peroxidase (HRP. The design of experiments technique (DOE and four different methods for biomolecule loading were compared using a rabbit IgG/goat anti-rabbit IgG ELISA model (adsorption, directional, covalent and a combination thereof. As a result, AuNP probes prepared by direct adsorption were the most effective method. AuNPs probes were then used to detect gliadin, one of the main components of wheat gluten, the protein composite that causes celiac disease. With this optimized approach, our data showed a sensitivity increase of at least five times and a lower detection limit with respect to a standard ELISA of at least three times. Additionally, the assay time was remarkably decreased.

  16. Development of monoclonal antibodies to pre-haptoglobin 2 and their use in an enzyme-linked immunosorbent assay (ELISA).

    Science.gov (United States)

    Flanagan, J J; Arjomandi, A; Delanoy, M L; Du Paty, E; Galea, P; Laune, D; Rieunier, F; Walker, R P; Binder, S R

    2014-04-01

    Haptoglobins (HPs) are alpha 2-globulin proteins that bind free hemoglobin in plasma to prevent oxidative damage. HPs are produced as preproteins that are proteolytically cleaved in the ER into alpha and beta chains prior to forming mature, functional tetramers. Two alleles exist in humans (HP1 and HP2), therefore three genotypes are present in the population, i.e., HP1-1, HP2-1, and HP2-2. A biochemical role for nascent haptoglobin 2 (pre-haptoglobin 2 or pre-HP2) as the only known modulator of intestinal permeability has been established. In addition, elevated levels of serum pre-HP2 have been detected in multiple conditions including celiac disease and type I diabetes, which are believed to result in part through dysregulation of the intestinal barrier. In this study, we report the development of a monoclonal antibody that is specific for pre-HP2 with a binding affinity in the nanomolar range. Additional antibodies with specificities for preHP but not mature haptoglobin were also characterized. A sandwich enzyme-linked immunosorbent assay (ELISA) was established and validated. The ELISA showed high specificity for pre-HP2 even in the presence of excess pre-HP1 or mature haptoglobins, and has excellent linearity and inter- and intra-assay reproducibility with a working range from 3.1ng/mL to 200ng/mL. Testing of sera from 76 healthy patients revealed a non-Gaussian distribution of pre-HP2 levels with a mean concentration of 221.2ng/mL (95% CI: 106.5-335.9ng/mL) and a median value of 23.9ng/mL. Compared to current approaches, this ELISA offers a validated, monoclonal-based method with high sensitivity and specificity for measuring pre-HP2 in human serum. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. An enzyme-linked immunosorbent assay (ELISA) for quantification of human collectin 11 (CL-11, CL-K1)

    Science.gov (United States)

    Selman, L.; Henriksen, M.L.; Brandt, J.; Palarasah, Y.; Waters, A.; Beales, P.L.; Holmskov, U.; Jørgensen, T.J.D.; Nielsen, C.; Skjodt, K.; Hansen, S.

    2012-01-01

    Collectin 11 (CL-11), also referred to as collectin kidney 1 (CL-K1), is a pattern recognition molecule that belongs to the collectin group of proteins involved in innate immunity. It interacts with glycoconjugates on pathogen surfaces and has been found in complex with mannose-binding lectin-associated serine protease 1 (MASP-1) and/or MASP-3 in circulation. Mutation in the CL-11 gene was recently associated with the developmental syndrome 3MC. In the present study, we established and thoroughly validated a sandwich enzyme-linked immunosorbent assay (ELISA) based on two different monoclonal antibodies. The assay is highly sensitive, specific and shows excellent quantitative characteristics such as reproducibility, dilution linearity and recovery (97.7–104%). The working range is 0.15–34 ng/ml. The CL-11 concentration in two CL-11-deficient individuals affected by the 3MC syndrome was determined to be below 2.1 ng/ml. We measured the mean serum CL-11 concentration to 284 ng/ml in 100 Danish blood donors, with a 95% confidence interval of 269–299 ng/ml. There was no significant difference in the CL-11 concentration measured in matched serum and plasma samples. Storage of samples and repeated freezing and thawing to a certain extent did not influence the ELISA. This ELISA offers a convenient and reliable method for studying CL-11 levels in relation to a variety of human diseases and syndromes. PMID:22301270

  18. Synergistic Use of Gold Nanoparticles (AuNPs) and “Capillary Enzyme-Linked Immunosorbent Assay (ELISA)” for High Sensitivity and Fast Assays

    Science.gov (United States)

    Kim, Wan-Joong; Cho, Hyo Young; Jeong, Bongjin; Byun, Sangwon; Huh, JaeDoo; Kim, Young Jun

    2017-01-01

    Using gold nanoparticles (AuNPs) on “capillary enzyme-linked immunosorbent assay (ELISA)”, we produced highly sensitive and rapid assays, which are the major attributes for point-of-care applications. First, in order to understand the size effect of AuNPs, AuNPs of varying diameters (5 nm, 10 nm, 15 nm, 20 nm, 30 nm, and 50 nm) conjugated with Horseradish Peroxidase (HRP)-labeled anti-C reactive protein (antiCRP) (AuNP•antiCRP-HRP) were used for well-plate ELISA. AuNP of 10 nm produced the largest optical density, enabling detection of 0.1 ng/mL of CRP with only 30 s of incubation, in contrast to 10 ng/mL for the ELISA run in the absence of AuNP. Then, AuNP of 10 nm conjugated with antiCRP-HRP (AuNP•antiCRP-HRP) was used for “capillary ELISA” to detect as low as 0.1 ng/mL of CRP. Also, kinetic study on both 96-well plates and in a capillary tube using antiCRP-HRP or AuNP•antiCRP-HRP showed a synergistic effect between AuNP and the capillary system, in which the fastest assay was observed from the “AuNP capillary ELISA”, with its maximum absorbance reaching 2.5 min, while the slowest was the typical well-plate ELISA with its maximum absorbance reaching in 13.5 min. PMID:29278402

  19. Enzyme-linked immunosorbent assay characterization of basal variation and heritability of systemic microfibrillar-associated protein 4.

    Directory of Open Access Journals (Sweden)

    Susanne Gjørup Sækmose

    Full Text Available BACKGROUND: Microfibrillar-associated protein 4 (MFAP4 is a systemic biomarker that is significantly elevated in samples from patients suffering from hepatic cirrhosis. The protein is generally localized to elastic fibers and other connective tissue fibers in the extracellular matrix (ECM, and variation in systemic MFAP4 (sMFAP4 has the potential to reflect diverse diseases with increased ECM turnover. Here, we aimed to validate an enzyme-linked immunosorbent assay (ELISA for the measurement of sMFAP4 with an emphasis on the robustness of the assay. Moreover, we aimed to determine confounders influencing the basal sMFAP4 variability and the genetic contribution to the basal variation. METHODS: The sandwich ELISA was based on two monoclonal anti-MFAP4 antibodies and was optimized and calibrated with a standard of recombinant MFAP4. The importance of pre-analytical sample handling was evaluated regarding sample tube type, time, and temperature conditions. The mean value structure and variance structure was determined in a twin cohort including 1,417 Danish twins (age 18-67 years by mixed-effect linear regression modeling. RESULTS: The practical working range of the sandwich ELISA was estimated to be 4-75 U/ml. The maximum intra- and inter-assay variation was estimated to be 8.7% and 6.6%, respectively. Sample handling and processing appeared to influence MFAP4 measurements only marginally. The average concentration of sMFAP4 in the serum was 18.9 ± 8.4 (SD U/ml in the twin cohort (95% CI: 18.5-19.4, median sMFAP4 17.3 U/ml. The mean structure model was demonstrated to include waist-hip ratio, age, and cigarette smoking status in interactions with gender. A relatively low heritability of h(2 = 0.24 was found after applying a model including additive genetic factors and shared and non-shared environmental factors. CONCLUSIONS: The described ELISA provides robust measures of the liver fibrosis marker sMFAP4. The low heritability and the relatively

  20. Quantification of urinary 5-hydroxyindoleacetic acid by in-house nitrosonaphthol reaction compared with nitrosonaphthol micro column chromatography and enzyme-linked immunosorbent assay

    Directory of Open Access Journals (Sweden)

    Joyce Matie Kinoshita da Silva

    2014-06-01

    Full Text Available The aim of this study was to compare the colorimetric "kit" and enzyme-linked immunosorbent assay (ELISA methods to quantify urinary 5-hydroxyindoleacetic acid through the Goldenberg's technique, exploring the potential of replacing it. 24-hour urine samples were tested by Goldenberg's assay and compared with kits. The agreement was almost perfect for the comparison of Goldenberg's assay with both colorimetric kit, and with ELISA kit, considering ≤ 7.5 mg/24h normal cutoff value. Therefore, both "kits" would be good alternatives to Goldenberg's technique due to practicality and agreement between values.

  1. Evaluation of three enzyme-linked immunosorbent assays for sarcoptic mange diagnosis and assessment in the Iberian ibex, Capra pyrenaica.

    Science.gov (United States)

    Ráez-Bravo, Arián; Granados, José Enrique; Serrano, Emmanuel; Dellamaria, Debora; Casais, Rosa; Rossi, Luca; Puigdemont, Anna; Cano-Manuel, Francisco Javier; Fandos, Paulino; Pérez, Jesús María; Espinosa, José; Soriguer, Ramón Casimiro; Citterio, Carlo; López-Olvera, Jorge Ramón

    2016-10-21

    Sarcoptic mange is a contagious skin disease caused by the mite Sarcoptes scabiei, affecting different mammalian species worldwide including the Iberian ibex (Capra pyrenaica), in which mortalities over 90 % of the population have been reported. No efficient diagnostic methods are available for this disease, particularly when there are low mite numbers and mild or no clinical signs. In this study, three enzyme-linked immunosorbent assays (ELISA) developed for dog (ELISA A), Cantabrian chamois (Rupicapra pyrenaica parva) (ELISA B) and Alpine chamois (Rupicapra rupicapra) (ELISA C), were evaluated to detect specific antibodies (IgG) to sarcoptic mange in Iberian ibex sera. Serum samples from 131 Iberian ibexes (86 healthy and 45 scabietic) were collected from 2005 to 2012 in the Sierra Nevada Natural and National Parks (southern Spain). Based on visual inspection, ibexes were classified into one of three categories, namely healthy (without scabietic compatible lesions), mildly affected (skin lesions over less than 50 % of the body surface) and severely affected (skin lesions over more than 50 % of the body surface). The optimal cut-off point, specificity, sensitivity and the area under the curve (AUC) were calculated, and the agreement between tests was determined. Moreover, differences in the optical density (OD) related to scabies severity have been evaluated for the best test. ELISA C showed better performance than the two other tests, reaching higher values of sensitivity (93.0 %) and specificity (93.5 %) against the visual estimation of the percentage of affected skin, chosen as the gold standard. Significantly higher concentrations of specific antibodies were observed with this test in the mildly and severely infested ibexes than in healthy ones. Our results revealed that ELISA C was an optimal test to diagnose sarcoptic mange in the Iberian ibex. Further studies characterizing immune response during the course of the disease, including spontaneous or drug

  2. The diagnostic significance of enzyme linked immuno-sorbent assay for herpes simplex, varicella zoster and cytomegalovirus retinitis.

    Directory of Open Access Journals (Sweden)

    Madhavan Hajib

    2003-01-01

    Full Text Available Purpose: To evaluate the diagnostic usefulness of enzyme linked immuno-sorbent assay (ELISA in single serum samples to associate herpes simplex virus (HSV, varicella zoster virus (VZV or cytomegalovirus (CMV with viral retinitis as against polymerase chain reaction (PCR on intraocular specimens. It was also designed to study the seroprevalence in normal healthy individuals, and the genomic prevalence of HSV, VZV and CMV in patients without an active viral inflammatory process. Methods: PCR for the detection of HSV, VZV and CMV genomes was done on 33 and 90 intraocular fluids from viral retinal patients and non-viral controls respectively. ELISA was done on 30 and 100 serum samples from viral retinitis patients and normal healthy controls respectively. Results: PCR did not detect HSV, VZV and CMV genomes except one, in which VZV-DNA was detected. ELISA showed prevalence rates of 28%, 83% and 90% for antibodies against HSV, VZV and CMV respectively in the normal population. In the 30 viral retinitis patients, PCR detected HSV-DNA in 2 (6.7%, VZV-DNA in 7 (23.3% and CMV-DNA in 6 (20.0% patients, while ELISA detected antibodies against HSV, VZV and CMV in 13 (43.3%, 24 (80.0% and 23 (76.7% patients respectively. ELISA was of value in indirect diagnosis only in 6 (20.0% as compared to 15 (50.0% of 30 patients by PCR, this difference was statistically significant (McNemar test, P value = 0.005. Conclusion: Serology by ELISA is no longer a useful diagnostic tool to associate HSV, VZV and CMV viruses with viral retinitis.

  3. Postabsorptive hyperglucagonemia in patients with type 2 diabetes mellitus analyzed with a novel enzyme-linked immunosorbent assay.

    Science.gov (United States)

    Matsuo, Toshihiro; Miyagawa, Jun-Ichiro; Kusunoki, Yoshiki; Miuchi, Masayuki; Ikawa, Takashi; Akagami, Takafumi; Tokuda, Masaru; Katsuno, Tomoyuki; Kushida, Akira; Inagaki, Takashi; Namba, Mitsuyoshi

    2016-05-01

    The aims of the present study were to investigate the performance of a novel sandwich enzyme-linked immunosorbent assay (ELISA) for measuring glucagon (1-29) with monoclonal antibodies against both the C- and N-terminal regions of glucagon (1-29), and to analyze the differences in plasma levels and responses of glucagon (1-29) to oral glucose loading in normal glucose tolerance (NGT) subjects and patients with type 2 diabetes mellitus. The cross-reactivity against proglucagon fragments using the ELISA kit and two types of conventional radioimmunoassay (RIA) kits was evaluated. A 75-g oral glucose tolerance test was carried out with NGT subjects and patients with type 2 diabetes mellitus, and the glucagon (1-29) concentration was measured using three types of kit. The ELISA kit clearly had the lowest cross-reactivity against miniglucagon (19-29) and glicentin (1-61). The oral glucose tolerance test was carried out with 30 NGT and 17 patients with type 2 diabetes mellitus. The glucagon (1-29) levels measured by the ELISA kit after glucose loading were significantly higher at all time-points in the type 2 diabetes mellitus group than in the NGT group. However, the glucagon (1-29) levels measured by one RIA kit were significantly higher in the NGT group, and those measured with the other RIA kit were approximately the same among the groups. The novel sandwich ELISA accurately determines plasma glucagon (1-29) concentrations with much less cross-reactivity against other proglucagon fragments than conventional RIA kits.

  4. Recombinase polymerase and enzyme-linked immunosorbent assay as a DNA amplification-detection strategy for food analysis

    Energy Technology Data Exchange (ETDEWEB)

    Santiago-Felipe, S.; Tortajada-Genaro, L.A.; Puchades, R.; Maquieira, A., E-mail: amaquieira@qim.upv.es

    2014-02-06

    Graphical abstract: -- Highlights: •Recombinase polymerase amplification is a powerful DNA method operating at 40 °C. •The combination RPA–ELISA gives excellent performances for high-throughput analysis. •Screening of food safety threats has been done using standard laboratory equipment. •Allergens, GMOs, bacteria, and fungi have been successfully determined. -- Abstract: Polymerase chain reaction in conjunction with enzyme-linked immunosorbent assay (PCR–ELISA) is a well-established technique that provides a suitable rapid, sensitive, and selective method for a broad range of applications. However, the need for precise rapid temperature cycling of PCR is an important drawback that can be overcome by employing isothermal amplification reactions such as recombinase polymerase amplification (RPA). The RPA–ELISA combination is proposed for amplification at a low, constant temperature (40 °C) in a short time (40 min), for the hybridisation of labelled products to specific 5′-biotinylated probes/streptavidin in coated microtiter plates at room temperature, and for detection by colorimetric immunoassay. RPA–ELISA was applied to screen common safety threats in foodstuffs, such as allergens (hazelnut, peanut, soybean, tomato, and maize), genetically modified organisms (P35S and TNOS), pathogenic bacteria (Salmonella sp. and Cronobacter sp.), and fungi (Fusarium sp.). Satisfactory sensitivity and reproducibility results were achieved for all the targets. The RPA–ELISA technique does away with thermocycling and provides a suitable sensitive, specific, and cost-effective method for routine applications, and proves particularly useful for resource-limited settings.

  5. Recombinase polymerase and enzyme-linked immunosorbent assay as a DNA amplification-detection strategy for food analysis

    International Nuclear Information System (INIS)

    Santiago-Felipe, S.; Tortajada-Genaro, L.A.; Puchades, R.; Maquieira, A.

    2014-01-01

    Graphical abstract: -- Highlights: •Recombinase polymerase amplification is a powerful DNA method operating at 40 °C. •The combination RPA–ELISA gives excellent performances for high-throughput analysis. •Screening of food safety threats has been done using standard laboratory equipment. •Allergens, GMOs, bacteria, and fungi have been successfully determined. -- Abstract: Polymerase chain reaction in conjunction with enzyme-linked immunosorbent assay (PCR–ELISA) is a well-established technique that provides a suitable rapid, sensitive, and selective method for a broad range of applications. However, the need for precise rapid temperature cycling of PCR is an important drawback that can be overcome by employing isothermal amplification reactions such as recombinase polymerase amplification (RPA). The RPA–ELISA combination is proposed for amplification at a low, constant temperature (40 °C) in a short time (40 min), for the hybridisation of labelled products to specific 5′-biotinylated probes/streptavidin in coated microtiter plates at room temperature, and for detection by colorimetric immunoassay. RPA–ELISA was applied to screen common safety threats in foodstuffs, such as allergens (hazelnut, peanut, soybean, tomato, and maize), genetically modified organisms (P35S and TNOS), pathogenic bacteria (Salmonella sp. and Cronobacter sp.), and fungi (Fusarium sp.). Satisfactory sensitivity and reproducibility results were achieved for all the targets. The RPA–ELISA technique does away with thermocycling and provides a suitable sensitive, specific, and cost-effective method for routine applications, and proves particularly useful for resource-limited settings

  6. Clinical Value of Specific Immunoglobulin E Detection by Enzyme-Linked Immunosorbent Assay in Cases of Acquired and Congenital Toxoplasmosis

    Science.gov (United States)

    Foudrinier, F.; Villena, I.; Jaussaud, R.; Aubert, D.; Chemla, C.; Martinot, F.; Pinon, J. M.

    2003-01-01

    The clinical value of immunoenzymatic (enzyme-linked immunosorbent assay) detection of anti-Toxoplasma immunoglobulin E (IgE) was assessed by studying 2,036 sera from 792 subjects, comprising seronegative controls and subjects with acute, active, reactivated, or congenital toxoplasmosis. Included were nonimmunized adults; pregnant women with recently acquired infection (acute toxoplasmosis); immunocompetent subjects with recently acquired severe infection (active toxoplasmosis) expressed as fever, adenopathies, splenomegaly, pneumonia, meningitis, or disseminated infection; subjects—some of them immunocompromised—whose previously moderate IgG antibody levels rose, suggesting a reactivation of quiescent toxoplasmosis; and infants born to seroconverted mothers and evaluated for diagnosis of congenital infection and therapeutic management. Specific IgE antibodies were never detected in seronegative subjects. They were present in 85.7% of asymptomatic seroconverters and in 100% of seroconverters with overt toxoplasmosis, following two different kinetics: in the former, the specific IgE titer generally presented a brief peak 2 to 3 months postinfection and then fell rapidly, whereas specific IgE persisted at a very high titer for several months in the latter. IgE emerged concomitantly with the increase in IgG during toxoplasmic reactivation. For neonatal diagnosis of congenital toxoplasmosis, IgE was less informative than IgM and IgA (sensitivities, 59.5, 64.3, and 76.2%, respectively) and had a specificity of 91.9%. Nevertheless, simultaneous measurement of the three isotypes at birth improved the diagnostic yield to 81% relative to the combination of IgA and IgM. Emergence of specific IgE during postnatal treatment for congenital toxoplasmosis is a sign of poor adherence or inadequate dosing. PMID:12682160

  7. The Diagnosis of Human Fascioliasis by Enzyme-Linked Immunosorbent Assay (ELISA) Using Recombinant Cathepsin L Protease

    Science.gov (United States)

    Gonzales Santana, Bibiana; Vasquez Camargo, Fabio; Parkinson, Michael

    2013-01-01

    Background Fascioliasis is a worldwide parasitic disease of domestic animals caused by helminths of the genus Fasciola. In many parts of the world, particularly in poor rural areas where animal disease is endemic, the parasite also infects humans. Adult parasites reside in the bile ducts of the host and therefore diagnosis of human fascioliasis is usually achieved by coprological examinations that search for parasite eggs that are carried into the intestine with the bile juices. However, these methods are insensitive due to the fact that eggs are released sporadically and may be missed in low-level infections, and fasciola eggs may be misclassified as other parasites, leading to problems with specificity. Furthermore, acute clinical symptoms as a result of parasites migrating to the bile ducts appear before the parasite matures and begins egg laying. A human immune response to Fasciola antigens occurs early in infection. Therefore, an immunological method such as ELISA may be a more reliable, easy and cheap means to diagnose human fascioliasis than coprological analysis. Methodology/Principal findings Using a panel of serum from Fasciola hepatica-infected patients and from uninfected controls we have optimized an enzyme-linked immunosorbent assay (ELISA) which employs a recombinant form of the major F. hepatica cathepsin L1 as the antigen for the diagnosis of human fascioliasis. We examined the ability of the ELISA test to discern fascioliasis from various other helminth and non-helminth parasitic diseases. Conclusions/Significance A sensitive and specific fascioliasis ELISA test has been developed. This test is rapid and easy to use and can discriminate fasciola-infected individuals from patients harbouring other parasites with at least 99.9% sensitivity and 99.9% specificity. This test will be a useful standardized method not only for testing individual samples but also in mass screening programs to assess the extent of human fascioliasis in regions where this

  8. The diagnosis of human fascioliasis by enzyme-linked immunosorbent assay (ELISA) using recombinant cathepsin L protease.

    Science.gov (United States)

    Gonzales Santana, Bibiana; Dalton, John P; Vasquez Camargo, Fabio; Parkinson, Michael; Ndao, Momar

    2013-01-01

    Fascioliasis is a worldwide parasitic disease of domestic animals caused by helminths of the genus Fasciola. In many parts of the world, particularly in poor rural areas where animal disease is endemic, the parasite also infects humans. Adult parasites reside in the bile ducts of the host and therefore diagnosis of human fascioliasis is usually achieved by coprological examinations that search for parasite eggs that are carried into the intestine with the bile juices. However, these methods are insensitive due to the fact that eggs are released sporadically and may be missed in low-level infections, and fasciola eggs may be misclassified as other parasites, leading to problems with specificity. Furthermore, acute clinical symptoms as a result of parasites migrating to the bile ducts appear before the parasite matures and begins egg laying. A human immune response to Fasciola antigens occurs early in infection. Therefore, an immunological method such as ELISA may be a more reliable, easy and cheap means to diagnose human fascioliasis than coprological analysis. Using a panel of serum from Fasciola hepatica-infected patients and from uninfected controls we have optimized an enzyme-linked immunosorbent assay (ELISA) which employs a recombinant form of the major F. hepatica cathepsin L1 as the antigen for the diagnosis of human fascioliasis. We examined the ability of the ELISA test to discern fascioliasis from various other helminth and non-helminth parasitic diseases. A sensitive and specific fascioliasis ELISA test has been developed. This test is rapid and easy to use and can discriminate fasciola-infected individuals from patients harbouring other parasites with at least 99.9% sensitivity and 99.9% specificity. This test will be a useful standardized method not only for testing individual samples but also in mass screening programs to assess the extent of human fascioliasis in regions where this zoonosis is suspected.

  9. Evaluation of an egg yolk enzyme-linked immunosorbent assay antibody test and its use to assess the prevalence of Mycoplasma gallisepticum infection in laying hens in Italy

    Directory of Open Access Journals (Sweden)

    Marco Tamba

    2010-01-01

    Full Text Available The prevalence of Mycoplasma gallisepticum infection in commercial layers was established by the presence of antibodies in eggs. Saline-extracted yolks were used with a commercial enzyme-linked immunosorbent assay kit. For the prevalence study, yolks from 30 eggs were obtained from each of 66 flocks coming from 36 layer farms. The prevalence of egg antibodies to Mycoplasma gallisepticum was 33.3% in single-age farms and 77.8% in multi-age farms. In 27 flocks, antibody titers were compared with results obtained from blood samples taken in the same flock and in the same period and analyzed with the same kit. This study has confirmed that egg yolk enzyme-linked immunosorbent assay antibody test is a suitable and practical approach for assessing the flock prevalence of Mycoplasma gallisepticum infection in layer hens.

  10. Detection of Candida albicans Sap2 in cancer patient serum samples by an indirect competitive enzyme-linked immunosorbent assay for the diagnosis of candidiasis

    OpenAIRE

    Yicun Wang; Xiang Gao; J U Zhi gang; Jingyuan Liu; Shuai Dong; Li Wang

    2013-01-01

    Background: The secreted aspartyl proteinases 2 (Sap2) of Candida albicans (C. albicans) is a potential marker of candididasis. It is a virulence factor associated with adherence and tissue invasion. Aim: In order to detect Sap2 in clinical sera, we developed an indirect competitive enzyme-linked immunosorbent assay (ELISA). Materials and Methods: Polyclonal antibodies were produced for Sap2 by injecting Sap2 into a New Zealand White inbred rabbit. They could be used at a dilution exceeding 1...

  11. Novel fluorescent probe for highly sensitive bioassay using sequential enzyme-linked immunosorbent assay-capillary isoelectric focusing (ELISA-cIEF).

    Science.gov (United States)

    Henares, Terence G; Uenoyama, Yuta; Nogawa, Yuto; Ikegami, Ken; Citterio, Daniel; Suzuki, Koji; Funano, Shun-ichi; Sueyoshi, Kenji; Endo, Tatsuro; Hisamoto, Hideaki

    2013-06-07

    This paper presents a novel rhodamine diphosphate molecule that allows highly sensitive detection of proteins by employing sequential enzyme-linked immunosorbent assay and capillary isoelectric focusing (ELISA-cIEF). Seven-fold improvement in the immunoassay sensitivity and a 1-2 order of magnitude lower detection limit has been demonstrated by taking advantage of the combination of the enzyme-based signal amplification of ELISA and the concentration of enzyme reaction products by cIEF.

  12. Measurement of Platelet-derived Microparticle Levels in the Chronic Phase of Cerebral Infarction Using an Enzyme-linked Immunosorbent Assay

    OpenAIRE

    Shirafuji, Toshihiko; Hamaguchi, Hirotoshi; Kanda, Fumio

    2008-01-01

    Assessment of platelet function is a critical component of the treatment andsecondary prevention of cerebral infarction, and measurement of platelet-derivedmicroparticle (PDMP) levels using flow cytometry may be a good indicator of plateletfunction. However, the flow cytometric analysis is not feasible in a variety of clinicalsituations. The goal of the present study was to measure PDMP levels using anenzyme-linked immunosorbent assay (ELISA) in chronic cerebral infarction patientsand to dete...

  13. Detection of Antibodies to U.S. Isolates of Avian Pneumovirus by a Recombinant Nucleocapsid Protein-Based Sandwich Enzyme-Linked Immunosorbent Assay

    OpenAIRE

    Gulati, Baldev R.; Munir, Shirin; Patnayak, Devi P.; Goyal, Sagar M.; Kapur, Vivek

    2001-01-01

    The nucleocapsid (N) protein of subgroup C (United States-specific) avian pneumovirus (APV/US) was expressed in Escherichia coli, and antibodies to the recombinant N protein were shown to specifically recognize the ≈47-kDa N protein of APV/US by Western immunoblot analysis. The recombinant APV/US N protein was used in a sandwich-capture enzyme-linked immunosorbent assay (ELISA), and the resulting assay was found to be more sensitive and specific than the routine indirect ELISA for the detecti...

  14. Comparative study on collagen-binding enzyme-linked immunosorbent assay and ristocetin cofactor activity assays for detection of functional activity of von Willebrand factor.

    Science.gov (United States)

    Turecek, Peter L; Siekmann, Jürgen; Schwarz, Hans Peter

    2002-04-01

    For more than two decades, the ristocetin cofactor (RCo) assay, which measures the von Willebrand factor (vWF)-mediated agglutination of platelets in the presence of the antibiotic ristocetin, has been the most common method for measuring the functional activity of vWF. There is, however, general agreement among clinical analysts that this method has major practical disadvantages in performance and reproducibility. Today, collagen-binding assays (CBA) based on the enzyme-linked immunosorbent assay (ELISA) technique that measure the interaction of vWF and collagen are an alternative analytic procedure based on a more physiological function than that of the RCo procedure. We used both assay systems in a comparative study to assess the functional activity of vWF in plasma as well as in therapeutic preparations. We measured RCo activities of plasma from healthy donors and patients with different types of von Willebrand disease (vWD) and of vWF as a drug substance in factor (F) VIII/vWF concentrates using both the aggregometric and the macroscopic methods. In addition, we measured collagen-binding activity (vWF:CB) using a recently developed commercially available CBA system. To investigate the relation between the structure and the functional activity of vWF, we isolated vWF species with different numbers of multimers from FVIII/vWF concentrates by affinity chromatography on immobilized heparin. The vWF:RCo and vWF:CB of the different fractions were measured, and the multimeric structure of vWF was analyzed by sodium dodecyl sulfate (SDS) agarose gel electrophoresis. (vWF:CB and vWF:RCo are part of the nomenclature proposed by the International Society on Thrombosis and Hemostasis Scientific and Standardization Committee [ISTH SSC] subcommittee on von Willebrand factor, in Maastricht, Germany, June 16, 2000.) Measurement of functional vWF activity by CBA can be carried out with substantially higher interassay reproducibility than can measurement of RCo. Both assay

  15. Multicountry Prospective Clinical Evaluation of Two Enzyme-Linked Immunosorbent Assays and Two Rapid Diagnostic Tests for Diagnosing Dengue Fever

    Science.gov (United States)

    Dauner, Allison L.; Valks, Andrea; Forshey, Brett M.; Long, Kanya C.; Thaisomboonsuk, Butsaya; Sierra, Gloria; Picos, Victor; Talmage, Sara; Morrison, Amy C.; Halsey, Eric S.; Comach, Guillermo; Yasuda, Chadwick; Loeffelholz, Michael; Jarman, Richard G.; Fernandez, Stefan; An, Ung Sam; Kochel, Tadeusz J.; Jasper, Louis E.; Wu, Shuenn-Jue L.

    2015-01-01

    We evaluated four dengue diagnostic devices from Alere, including the SD Bioline Dengue Duo (nonstructural [NS] 1 Ag and IgG/IgM), the Panbio Dengue Duo Cassette (IgM/IgG) rapid diagnostic tests (RDTs), and the Panbio dengue IgM and IgG capture enzyme-linked immunosorbent assays (ELISAs) in a prospective, controlled, multicenter study in Peru, Venezuela, Cambodia, and the United States, using samples from 1,021 febrile individuals. Archived, well-characterized samples from an additional 135 febrile individuals from Thailand were also used. Reference testing was performed on all samples using an algorithm involving virus isolation, in-house IgM and IgG capture ELISAs, and plaque reduction neutralization tests (PRNT) to determine the infection status of the individual. The primary endpoints were the clinical sensitivities and specificities of these devices. The SD Bioline Dengue Duo had an overall sensitivity of 87.3% (95% confidence interval [CI], 84.1 to 90.2%) and specificity of 86.8% (95% CI, 83.9 to 89.3%) during the first 14 days post-symptom onset (p.s.o.). The Panbio Dengue Duo Cassette demonstrated a sensitivity of 92.1% (87.8 to 95.2%) and specificity of 62.2% (54.5 to 69.5%) during days 4 to 14 p.s.o. The Panbio IgM capture ELISA had a sensitivity of 87.6% (82.7 to 91.4%) and specificity of 88.1% (82.2 to 92.6%) during days 4 to 14 p.s.o. Finally, the Panbio IgG capture ELISA had a sensitivity of 69.6% (62.1 to 76.4%) and a specificity of 88.4% (82.6 to 92.8%) during days 4 to 14 p.s.o. for identification of secondary dengue infections. This multicountry prospective study resulted in reliable real-world performance data that will facilitate data-driven laboratory test choices for managing patient care during dengue outbreaks. PMID:25588659

  16. High seroprevalence of Mycoplasma pneumoniae IgM in acute Q fever by enzyme-linked immunosorbent assay (ELISA.

    Directory of Open Access Journals (Sweden)

    Chung-Hsu Lai

    Full Text Available Q fever is serologically cross-reactive with other intracellular microorganisms. However, studies of the serological status of Mycoplasma pneumoniae and Chlamydophila pneumoniae during Q fever are rare. We conducted a retrospective serological study of M. pneumoniae and C. pneumoniae by enzyme-linked immunosorbent assay (ELISA, a method widely used in clinical practice, in 102 cases of acute Q fever, 39 cases of scrub typhus, and 14 cases of murine typhus. The seropositive (57.8%, 7.7%, and 0%, p<0.001 and seroconversion rates (50.6%, 8.8%, and 0%, p<0.001 of M. pneumoniae IgM, but not M. pneumoniae IgG and C. pneumoniae IgG/IgM, in acute Q fever were significantly higher than in scrub typhus and murine typhus. Another ELISA kit also revealed a high seropositivity (49.5% and seroconversion rate (33.3% of M. pneumoniae IgM in acute Q fever. The temporal and age distributions of patients with positive M. pneumoniae IgM were not typical of M. pneumoniae pneumonia. Comparing acute Q fever patients who were positive for M. pneumoniae IgM (59 cases with those who were negative (43 cases, the demographic characteristics and underlying diseases were not different. In addition, the clinical manifestations associated with atypical pneumonia, including headache (71.2% vs. 81.4%, p=0.255, sore throat (8.5% vs. 16.3%, p=0.351, cough (35.6% vs. 23.3%, p=0.199, and chest x-ray suggesting pneumonia (19.3% vs. 9.5%, p=0.258, were unchanged between the two groups. Clinicians should be aware of the high seroprevalence of M. pneumoniae IgM in acute Q fever, particularly with ELISA kits, which can lead to misdiagnosis, overestimations of the prevalence of M. pneumoniae pneumonia, and underestimations of the true prevalence of Q fever pneumonia.

  17. Evaluation of guppy (Poecilia reticulata Peters) immunization against Tetrahymena sp. by enzyme-linked immunosorbent assay (ELISA).

    Science.gov (United States)

    Sharon, Galit; Nath, Pulak R; Isakov, Noah; Zilberg, Dina

    2014-09-15

    Analysis of the effectiveness of guppy (Poecilia reticulata Peters) immunization based on measurements of antibody (Ab) titers suffers from a shortage of reagents that can detect guppy antibodies (Abs). To overcome this problem, we immunized mice with different preparations of guppy immunoglobulins (Igs) and used the mouse antisera to develop a quantitative enzyme-linked immunosorbent assay (ELISA). The most efficient immunogen for mouse immunization was guppy Igs adsorbed on protein A/G beads. Antisera from mice boosted with this immunoglobulin (Ig) preparation were highly specific and contained high Ab titers. They immunoreacted in a Western blot with Ig heavy and light chains from guppy serum, and Ig heavy chain from guppy whole-body homogenate. The mouse anti-guppy Ig was applied in an ELISA aimed at comparing the efficiency of different routes of guppy immunization against Tetrahymena: (i) anal intubation with sonicated Tetrahymena (40,000 Tetrahymena/fish in a total volume of 10 μL) mixed with domperidon, deoxycholic acid and free amino acids (valine, leucine, isoleucine, phenylalanine and tryptophan), or (ii) intraperitoneal (i.p.) injection of sonicated Tetrahymena in complete Freund's adjuvant (15,000 Tetrahymena/fish in total a volume of 20 μL). Negative control fish were anally intubated with the intubation mixture without Tetrahymena, or untreated. ELISA measurement of anti-Tetrahymena Ab titer revealed a significantly higher level of Abs in i.p.-immunized guppies, compared to the anally intubated and control fish. In addition, the efficiency of immunization was tested by monitoring guppy mortality following (i) i.p. challenge with Tetrahymena (900 Tetrahymena/fish) or (ii) cold stress followed by immersion in water containing 10,000 Tetrahymena/mL. Fish mortality on day 14 post-Tetrahymena infection by i.p. injection exceeded 50% in the control and anally intubated fish, compared to 31% in i.p.-immunized fish. Immunization did not protect from

  18. Nucleic acid detection based on the use of microbeads: a review

    International Nuclear Information System (INIS)

    Rödiger, Stefan; Liebsch, Claudia; Schmidt, Carsten; Schierack, Peter; Lehmann, Werner; Resch-Genger, Ute; Schedler, Uwe

    2014-01-01

    Microbead-based technologies represent elegant and versatile approaches for highly parallelized quantitative multiparameter assays. They also form the basis of various techniques for detection and quantification of nucleic acids and proteins. Nucleic acid-based methods include hybridization assays, solid-phase PCR, sequencing, and trapping assays. Microbead assays have been improved in the past decades and are now important tools in routine and point-of-care diagnostics as well as in life science. Its advances include low costs, low workload, high speed and high-throughput automation. The potential of microbead-based assays therefore is apparent, and commercial applications can be found in the detection and discrimination of single nucleotide polymorphism, of pathogens, and in trapping assays. This review provides an overview on microbead-based platforms for biosensing with a main focus on nucleic acid detection (including amplification strategies and on selected probe systems using fluorescent labeling). Specific sections cover chemical properties of microbeads, the coupling of targets onto solid surfaces, microbead probe systems (mainly oligonucleotide probes), microbead detection schemes (with subsections on suspension arrays, microfluidic devices, and immobilized microbeads), quantification of nucleic acids, PCR in solution and the detection of amplicons, and methods for solid-phase amplification. We discuss selected trends such as microbead-coupled amplification, heterogeneous and homogenous DNA hybridization assays, real-time assays, melting curve analysis, and digital microbead assays. We finally discuss the relevance and trends of the methods in terms of high-level multiplexed analysis and their potential in diagnosis and personalized medicine. (author)

  19. Semiquantitative determination of ergot alkaloids in seed, straw, and digesta samples using a competitive enzyme-linked immunosorbent assay.

    Science.gov (United States)

    Schnitzius, J M; Hill, N S; Thompson, C S; Craig, A M

    2001-05-01

    Ergot alkaloids present in endophyte-infected (E+) tall fescue cause fescue toxicosis and other toxic effects in livestock that consume infected plant tissue, leading to significant financial losses in livestock production each year. The predominant method currently in use for quantifying ergot alkaloid content in plant tissue is through high-performance liquid chromatography (HPLC), which quantifies the amount of ergovaline, one of many ergot alkaloids in E+ plant tissue. The enzyme-linked immunosorbent assay (ELISA) method used in this study detects quantities of nonspecific ergot alkaloids and therefore accounts for greater amounts of the total ergot alkaloid content in E+ tissue than does HPLC. The ELISA can also be used to more expediently analyze a larger number of forage samples without sophisticated and costly analytical equipment and therefore could be more desirable in a diagnostic setting. The purpose of this study was to evaluate the between-day and within-run variability of the ELISA and to determine the binding efficiency of 6 ergot alkaloids to the 15F3.E5 antibody used in the competitive ELISA to ascertain its feasibility as a quick analysis tool for ergot alkaloids. Straw samples had an average coefficient of variation (CV) for concentration of 10.2% within runs and 18.4% between runs, and the seed samples had an average CV for concentration of 13.3% within runs and 24.5% between runs. The grass tissue-based lysergic acid standard curve calculated from the ELISA had an average r2 of 0.99, with a CV of 2.1%. Ergocryptine, ergocristine, ergocornine, and ergotamine tartrate did not bind strongly to the 15F3.E5 antibody because of the presence of large side groups on these molecules, which block their binding to the antibody, whereas ergonovine and ergonovine maleate were bound much more efficiently because of their structural similarity to lysergic acid. Clarified rumen fluid was tested as an additional matrix for use in the ergot alkaloid competitive

  20. Relation between enzyme-linked immunosorbent assay and radioimmunoassay for detection of antibodies to the capsular polysaccharide of Haemophilus influenzae type b

    International Nuclear Information System (INIS)

    Kristensen, K.; Weis Bentzon, M.

    1992-01-01

    The measurement of antibodies to the capsular polysaccharide (PRP) of Haemophilus influenzae type b (Hib) is important because vaccines inducing such antibodies are now available. We developed and evaluated an enzyme-linked immunosorbent assay (ELISA) for detection of these antibodies based on direct coating of the plates with tyraminated PRP. The assay fulfilled the requirements for parallel line assays; it was sensitive, specific, and reproducible with a coefficient of variation between days of 19%. Results from the ELISA were compared with results from radioimmunoassay and a correlation coefficient of 0.93 was found. Results obtained by the two methods were proportional and the relation was indepenedent of the antibody level. The relation between them was also unaffected by the contribution of different antibody isotypes, indicating that these were measured to the same extent by both methods. ELISA employing direct coating of the plates with tyraminated PRP represents a useful alternative for detection of antibodies when studying immunogenicity of Hib vaccines. (au)

  1. Enzyme-linked immunosorbent serum assay specific for the 7S domain of Collagen Type IV (P4NP 7S)

    DEFF Research Database (Denmark)

    Leeming, Diana J; Nielsen, Mette J; Dai, Yueqin

    2012-01-01

    Aim:  The present study describes the ability of a newly developed N-terminal pro-peptides of type IV collagen 7S domain (P4NP 7S) competitive enzyme-linked immunosorbent assay (ELISA) for describing liver fibrosis. The assay applies a monoclonal antibody specific for a PIVNP 7S epitope 100...... were significantly elevated in rat with liver fibrosis as seen by histology (CCL4: 283% elevated in the highest quartile of total hepatic collagen compared with controls, P = 0.001; BDL: 183% elevated at week 4 compared with sham, P type IV collagen...... expression in BDL rats (r = 0.49, P serum assay specific for P4NP 7S was highly related to liver fibrosis...

  2. Generation of monoclonal antibodies against peptidylarginine deiminase 2 (PAD2) and development of a PAD2-specific enzyme-linked immunosorbent assay

    DEFF Research Database (Denmark)

    Damgaard, Dres; Palarasah, Yaseelan; Skjødt, Karsten

    2014-01-01

    The enzyme peptidylarginine deiminase 2 (PAD2) has been associated with inflammatory diseases, such as rheumatoid arthritis and neurodegenerative diseases including multiple sclerosis. To investigate the association of various diseases with extracellular PAD2, we raised monoclonal antibodies (m......Abs) against rabbit PAD2 and evaluated their cross-reactivity with human PAD2 by indirect enzyme-linked immunosorbent assay (ELISA), western blotting and immunohistological staining of inflamed synovial tissue. Moreover, we established a sandwich ELISA detecting human PAD2, based on two different monoclonal...... diseases....

  3. Quantitation of pulmonary surfactant protein SP-B in the absence or presence of phospholipids by enzyme-linked immunosorbent assay

    DEFF Research Database (Denmark)

    Oviedo, J M; Valiño, F; Plasencia, I

    2001-01-01

    We have developed an enzyme-linked immunosorbent assay (ELISA) that uses polyclonal or monoclonal anti-surfactant protein SP-B antibodies to quantitate purified SP-B in chloroform/methanol and in chloroform/methanol extracts of whole pulmonary surfactant at nanogram levels. This method has been...... used to explore the effect of the presence of different phospholipids on the immunoreactivity of SP-B. Both polyclonal and monoclonal antibodies produced reproducible ELISA calibration curves for methanolic SP-B solutions with protein concentrations in the range of 20-1000 ng/mL. At these protein...

  4. Comparison of electron microscopy, enzyme-linked immunosorbent assay, solid-phase radioimmunoassay, and indirect immunofluorescence for detection of human rotavirus antigen in faeces

    Energy Technology Data Exchange (ETDEWEB)

    Birch, C J; Lehmann, N I; Hawker, A J; Marshall, J A; Gust, I D [Fairfield Hospital for Communicable Diseases, Victoria (Australia). Virology Dept.

    1979-07-01

    Four techniques were compared for their practicability, speed, and sensitivity for the detection of human rotavirus. Radioimmunoassay (RIA) and enzyme-linked immunosorbent assay (ELISA) were found to be the most sensitive means of identifying rotavirus and, once processed, up to 40 specimens could be examined daily. Electron microscopy, although less sensitive than these techniques, had the advantage of being able to detect other viral agents present in faecal extracts. Indirect immunofluorescence failed to detect rotavirus as often as the other three methods. In laboratories where routine examination of faecal specimens from patients with gastroenteritis is required, ELISA and RIA are useful alternatives to electron microscopy.

  5. Comparison of enzyme-linked immunosorbent assay, radioimmunoassay, complement fixation, anticomplement immunofluorescence and passive haemaglutination techniques for detecting cytomegalovirus IgG antibody

    Energy Technology Data Exchange (ETDEWEB)

    Booth, J C; Hannington, G; Bakir, T M.F.; Stern, H; Kangro, H; Griffiths, P D; Heath, R B [Saint George' s Hospital Medical School, London (UK); Saint Bartholomew' s Hospital, London (UK))

    1982-12-01

    The radioimmunoassay (RIA) and enzyme-linked immunosorbent assay (ELISA) techniques were found to be comparable in sensitivity and specificity for detecting cytomegalovirus IgG antibody, and 10 to 100 times more sensitive than complement-fixation (CF), anticomplement immunofluorescence (ACIF) and passive haemagglutination (PHA). In screening tests for antibody, the frequency of false-positive and -negative results was 0.6% for RIA and ELISA, 1.5% for CF, 1.6% for ACIF and 3.6% for PHA. PHA was the least satisfactory test, largely because of technical problems.

  6. Detection of H5 Avian Influenza Viruses by Antigen-Capture Enzyme-Linked Immunosorbent Assay Using H5-Specific Monoclonal Antibody▿

    OpenAIRE

    He, Qigai; Velumani, Sumathy; Du, Qingyun; Lim, Chee Wee; Ng, Fook Kheong; Donis, Ruben; Kwang, Jimmy

    2007-01-01

    The unprecedented spread of highly pathogenic avian influenza virus subtype H5N1 in Asia and Europe is threatening animals and public health systems. Effective diagnosis and control management are needed to control the disease. To this end, we developed a panel of monoclonal antibodies (MAbs) against the H5N1 avian influenza virus (AIV) and implemented an antigen-capture enzyme-linked immunosorbent assay (AC-ELISA) to detect the H5 viral antigen. Mice immunized with denatured hemagglutinin (H...

  7. Direct Human Papillomavirus E6 Whole-Cell Enzyme-Linked Immunosorbent Assay for Objective Measurement of E6 Oncoproteins in Cytology Samples

    OpenAIRE

    Yang, Yi-Shan; Smith-McCune, Karen; Darragh, Teresa M.; Lai, Yvonne; Lin, Ju-Hwa; Chang, Ting-Chang; Guo, Hsiao-Yun; Kesler, Tiea; Carter, Alicia; Castle, Philip E.; Cheng, Shuling

    2012-01-01

    A novel, whole-cell enzyme-linked immunosorbent assay (ELISA) based on a non-type-specific anti-human papillomavirus (HPV) E6 antibody was tested on 182 residual cytological specimens. For samples with a designation of more severe than cervical intraepithelial neoplasia grade 3 (CIN3+), 83% tested positive for E6; in a subset with paired testing for E6 ELISA and HPV DNA, 72% tested E6 positive and 92% tested high-risk (HR)-HPV DNA positive (P = 0.2). Among the women with a less than CIN3 diag...

  8. Comparison of electron microscopy, enzyme-linked immunosorbent assay, solid-phase radioimmunoassay, and indirect immunofluorescence for detection of human rotavirus antigen in faeces

    International Nuclear Information System (INIS)

    Birch, C.J.; Lehmann, N.I.; Hawker, A.J.; Marshall, J.A.; Gust, I.D.

    1979-01-01

    Four techniques were compared for their practicability, speed, and sensitivity for the detection of human rotavirus. Radioimmunoassay (RIA) and enzyme-linked immunosorbent assay (ELISA) were found to be the most sensitive means of identifying rotavirus and, once processed, up to 40 specimens could be examined daily. Electron microscopy, although less sensitive than these techniques, had the advantage of being able to detect other viral agents present in faecal extracts. Indirect immunofluorescence failed to detect rotavirus as often as the other three methods. In laboratories where routine examination of faecal specimens from patients with gastroenteritis is required, ELISA and RIA are useful alternatives to electron microscopy. (author)

  9. USE OF AN INDIRECT ENZYME-LINKED IMMUNOSORBENT ASSAY (ELISA TO DETECT ANTIBODIES IN AYU (Plecogiossus altivelis VACCINATED BY IMMERSION ADMINISTRATION

    Directory of Open Access Journals (Sweden)

    . Sukenda

    2007-05-01

    Full Text Available ABSTRACTAn indirect enzyme-linked immunosorbent assay (ELISA was used to detect serum antibody in ayu, Plecoglossus altivelis, immunized against Pseudomonasplecoglossicida by immersion vaccination.  First, the procedure of the ELISA was optimized and the sensitivity was checked.  Secondly, the formalin-killed cells (FKC of P. plecoglossicida was administered to ayu by immersion vaccination.  Two weeks after vaccination, fish were divided into two groups, one group was given booster.  The level of specific antibody production of both boostered and vaccinated only fish were statistically higher than unvaccinated control fish at the time of each blood collection.  However, the differences between the boostered and vaccinated only fish were not statistically significant.Keywords :  immunization, Pseudomonas plecoglossicida, ayu, ELISA ABSTRAKIndirect enzyme-linked immunosorbent assay (ELISA digunakan untuk mendeteksi antibodi pada ayu, Plecoglossus altivelis, yang diimunisasi dengan cara perendaman untuk melawan infeksi Pseudomonas plecoglossicida.  Pertama, prosedur ELISA dioptimasikan dan sensitivitas dari metode ini juga diperiksa.  Kemudian, bakteri Plecoglossus altivelis yang sudah dimatikan dengan formalin diberikan ke ikan ayu dengan vaksinasi perendaman.  Dua minggu setelah vaksinasi, ikan dibagi menjadi dua kelompok, satu kelompok diberi vaksinasi kedua.  Produksi antibodi spesifik dari ikan-ikan yang divaksinasi satu kali dengan vaksinasi dua kaii secara statistik lebih tinggi dibandingkan dengan control.  Akan tetapi, tidak ada perbedaan produksi antibodi antara ikan yarig divaksanisi satu kali dengan divaksinasi dua kali.Kata kunci :  imunisasi, Pseudomonasplecoglossicida, ayu, ELISA

  10. Development of a biomimetic enzyme-linked immunosorbent assay based on molecularly imprinted polymers on paper for the detection of carbaryl.

    Science.gov (United States)

    Zhang, Can; Cui, Hanyu; Han, Yufeng; Yu, Fangfang; Shi, Xiaoman

    2018-02-01

    A biomimetic enzyme-linked immunosorbent assay (BELISA) which was based on molecularly imprinted polymers on paper (MIPs-paper) with specific recognition was developed. As a detector, the surface of paper was modified with γ-MAPS by hydrolytic action and anchored the MIP layer on γ-MAPS modified-paper by copolymerization to construct the artificial antibody Through a series of experimentation and verification, we successful got the MIPs-paper and established BELISA for the detection of carbaryl. The development of MIPs-paper based on BELISA was applied to detect carbaryl in real samples and validated by an enzyme-linked immunosorbent assay (ELISA) based on anti-carbaryl biological antibody. The results of these two methods (BELISA and ELISA) were well correlated (R 2 =0.944). The established method of MIPs-paper BELISA exhibits the advantages of low cost, higher stability and being re-generable, which can be applied as a convenient tool for the fast and efficient detection of carbaryl. Copyright © 2017. Published by Elsevier Ltd.

  11. An enzyme-linked immunosorbent assay for monoester-type aconitic alkaloids and its application in the pharmacokinetic study of benzoylhypaconine in rats.

    Science.gov (United States)

    Liu, Can-Can; Xu, Yun-Hui; Yuan, Shuai; Xu, Yu; Hua, Mo-Li

    2018-04-01

    A new enzyme-linked immunosorbent assay (ELISA) method for quantitative determination of monoester-type aconitic alkaloids was developed. The antibodies derived from the immunogen of benzoylmesaconine (BM) could be electively affined to benzoylaconitine-type alkaloids with an ester bond (14-benzoyl-), especially to benzoylhypaconine (BH, 140.02% of cross-reactivity). The effective working range of BH was 1 ng/ml to 5 μg/ml; the lower limit of detection and the quantification were 0.35 and 0.97 ng/ml, respectively. The values of CV for intra-day and inter-day assays and recovery ratios were in acceptable ranges. The results of stability experiments were also satisfactory. This validated method was employed for pharmacokinetic study of BH in rats and the bioavailability orally administered was estimated to be 16.3%.

  12. Development and Validation of an Enzyme-Linked Immunosorbent Assay for the Detection of Binding Anti-Drug Antibodies against Interferon Beta

    DEFF Research Database (Denmark)

    Ingenhoven, Kathleen; Kramer, Daniel; Jensen, Poul Erik Hyldgaard

    2017-01-01

    to be 26 ng/mL using commercially available polyclonal rabbit antihuman IFN-β in human sera as the positive control. CONCLUSION: An ultrasensitive ELISA for IFN-β-binding ADA testing has been validated. This will form the basis to assess anti-biopharmaceutical immunization toward IFN-β with regards to its......OBJECTIVE: To develop and validate a method for the detection of binding anti-drug antibodies (ADAs) against interferon beta (IFN-β) in human serum as part of a European initiative (ABIRISK) aimed at the prediction and analysis of clinical relevance of anti-biopharmaceutical immunization...... to minimize the risk. METHOD: A two-tiered bridging enzyme-linked immunosorbent assay (ELISA) format was selected and validated according to current recommendations. Screening assay: ADA in serum samples form complexes with immobilized IFN-β and biotinylated IFN-β, which are then detected using HRP labeled...

  13. Autoreactive lymphocytes in thyroid disorders. 2. Comparison of anti-thyroglobulin antibody production by plaque-forming cell, radio-immunological and enzyme-linked immunosorbent assays

    Energy Technology Data Exchange (ETDEWEB)

    Petersen, J; Feldt-Rasmussen, U; Siersbaek-Nielsen, K; Hoeier-Madsen, M; Larsen, F; Husby, S

    1986-01-01

    Blood mononuclear cells (MNC) from 9 randomly selected patients with autoimmune thyroiditis were stimulated in vitro with pokeweed mitogen (PWM), a polyclonal B lymphocyte activator. The secretion of immunoglobulins (Ig) and anti-thyroglobulin antibodies (TgAb) was assayed by means of haemolytic plaque-forming cell (PFC) assays, radioimmune assay (RIA) and enzyme-linked immunosorbent assays (ELISA). Total Ig and TgAb production was maximal using MNC cultured at 1.0 x 10/sup 6//ml as estimated by PFC, RIA and ELISA. The Ig and TgAb production as measured by RIA and ELISA was 1.5 - 3 times higher after 12 days' culture compared to 6 days' culture. Ig and TgAb production measured by PFC-assays at day 6 correlated positively to the results obtained by RIA and ELISA at day 12. PWM-induced TgAb secretion correlated positively to TgAb titres in serum. As judged by PFC, TgAb production was found in 8/9 patients; about 5% (range 0 - 7.9%) of the total PWM-stimulated IgG-secreting cells were involved in TgAb secretion. TgAb production as measured by ELISA and RIA was found in 6/9 patients. By reference to an affinity-purified human TgAb preparation, the TgAb secretion was about 0.7% (range 0 - 21.3%) of the total PWM-induced IgG secretion.

  14. Development and Validation of an Enzyme-Linked Immunosorbent Assay for the Detection of Binding Anti-Drug Antibodies against Interferon Beta

    Directory of Open Access Journals (Sweden)

    Kathleen Ingenhoven

    2017-07-01

    Full Text Available ObjectiveTo develop and validate a method for the detection of binding anti-drug antibodies (ADAs against interferon beta (IFN-β in human serum as part of a European initiative (ABIRISK aimed at the prediction and analysis of clinical relevance of anti-biopharmaceutical immunization to minimize the risk.MethodA two-tiered bridging enzyme-linked immunosorbent assay (ELISA format was selected and validated according to current recommendations. Screening assay: ADA in serum samples form complexes with immobilized IFN-β and biotinylated IFN-β, which are then detected using HRP labeled Streptavidin and TMB substrate. Confirmation assay: Screen “putative positive” samples are tested in the presence of excess drug (preincubation of sera with 0.3 µg/mL of soluble IFN-β and percentage of inhibition is calculated.ResultsThe assay is precise, and the sensitivity of the assay was confirmed to be 26 ng/mL using commercially available polyclonal rabbit antihuman IFN-β in human sera as the positive control.ConclusionAn ultrasensitive ELISA for IFN-β-binding ADA testing has been validated. This will form the basis to assess anti-biopharmaceutical immunization toward IFN-β with regards to its clinical relevance and may allow for the development of predictive tools, key aims within the ABIRISK consortium.

  15. A simple, specific high-throughput enzyme-linked immunosorbent assay (ELISA) for quantitative determination of melatonin in cell culture medium.

    Science.gov (United States)

    Li, Ye; Cassone, Vincent M

    2015-09-01

    A simple, specific, high-throughput enzyme-linked immunosorbent assay (ELISA) for quantitative determination of melatonin was developed for directly measuring melatonin in cell culture medium with 10% FBS. This assay adopts a commercial monoclonal melatonin antibody and melatonin-HRP conjugate, so it can be applied in multiple labs rapidly with low cost compared with commercial RIA and ELISA kits. In addition, the procedure is much simpler with only four steps: 1) sample/conjugate incubation, 2) plate washing, 3) TMB color reaction and 4) reading of results. The standards of the assay cover a wide working range from 100 pg/mL to 10 ng/mL. The sensitivity was 68 pg/mL in cell culture medium with 10% FBS and 26 pg/mL in PBS with as little as 25 μL sample volume. The recovery of melatonin from cell culture medium was 101.0%. The principal cross-reacting compound was 5-methoxytryptophol (0.1%). The variation coefficients of the assay, within and between runs, ranged between 6.68% and 15.76% in cell culture medium. The mean linearity of a series diluted cell culture medium sample was 105% (CV=5%), ranging between 98% and 111%, y=5.5263x+0.0646, R(2)=0.99. The assay enables small research and teaching labs to reliably measure this important neurohormone. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. Development of sensitive direct and indirect enzyme-linked immunosorbent assays (ELISAs) for monitoring bisphenol-A in canned foods and beverages.

    Science.gov (United States)

    Lu, Yang; Peterson, Joshua Richard; Gooding, John Justin; Lee, Nanju Alice

    2012-06-01

    Enzyme-linked immunosorbent assays (ELISAs) are investigated in this work for the detection of bisphenol-A (BPA), a plastic monomer and a critical contaminant in food and environment. A series of polyclonal antibodies generated in vivo using BPA-butyrate-protein conjugate and BPA-valerate-protein conjugate were evaluated on direct and indirect competitive assay formats with five competing haptens (BPA-butyrate, BPA-valerate, BPA-crotonate, BPA-acetate, and BPA-2-valerate). Two indirect ELISAs and one direct ELISA exhibiting high sensitivity and specificity for BPA were developed. The 50 % inhibition of antibody binding (IC(50)) values were 0.78 ± 0.01-1.20 ± 0.26 μg L(-1), and the limits of detection as measured by the IC(20) values were 0.10 ± 0.03-0.20 ± 0.04 μg L(-1). The assays were highly specific to BPA, only displaying low cross-reactivity (3-8 % for the indirect assays and 26 % for the direct assay) for 4-cumylphenol (4-CP), at pH 7.2. The degree of cross-reaction of 4-CP was influenced by the antibody/hapten conjugate combination, assay conditions, and the assay format. The assays were optimized for the analysis of BPA in canned vegetables, bottled water and carbonated drinks. The limits of quantification for these three evaluated sample types, based on the spike and recovery data, were 0.5, 2.5, and 100 μg L(-1), respectively.

  17. Pistachio (Pistacia vera L.) Detection and Quantification Using a Murine Monoclonal Antibody-Based Direct Sandwich Enzyme-Linked Immunosorbent Assay.

    Science.gov (United States)

    Liu, Changqi; Chhabra, Guneet S; Sathe, Shridhar K

    2015-10-21

    A commercially available direct sandwich enzyme-linked immunosorbent assay (ELISA) (BioFront Technologies, Tallahassee, FL, USA) using murine anti-pistachio monoclonal antibodies (mAbs) as capture and detection antibodies was evaluated. The assay was sensitive (limit of detection = 0.09 ± 0.02 ppm full fat pistachio, linear detection range = 0.5-36 ppm, 50% maximum signal concentration = 7.9 ± 0.7 ppm), reproducible (intra- and inter-assay variability pistachio seeds subjected to autoclaving (121 °C, 15 psi, 15, 30 min), blanching (100 °C, 5, 10 min), frying (191 °C, 1 min), microwaving (500, 1000 W, 3 min), and dry roasting (140 °C, 30 min; 168 °C, 12 min). No cross-reactivity was observed in 156 food matrices, each tested at 100,000 ppm, suggesting the ELISA to be pistachio specific. The pistachio recovery ranges for spiked (10 ppm) and incurred (10-50000 ppm) food matrices were 93.1-125.6% and 35.7-112.2%, respectively. The assay did not register any false-positive or -negative results among the tested commercial and laboratory prepared samples.

  18. Simple Identification of Human Taenia Species by Multiplex Loop-Mediated Isothermal Amplification in Combination with Dot Enzyme-Linked Immunosorbent Assay.

    Science.gov (United States)

    Nkouawa, Agathe; Sako, Yasuhito; Okamoto, Munehiro; Ito, Akira

    2016-06-01

    For differential detection of Taenia solium, Taenia saginata, and Taenia asiatica, loop-mediated isothermal amplification (LAMP) assay targeting the cytochrome c oxidase subunit 1 gene has been recently developed and shown to be sensitive, specific, and effective. However, to achieve differential identification, one specimen requires three reaction mixtures containing a primer set of each Taenia species separately, which is complex and time consuming and increases the risk of cross-contamination. In this study, we developed a simple differential identification of human Taenia species using multiplex LAMP (mLAMP) in combination with dot enzyme-linked immunosorbent assay (dot-ELISA). Forward inner primers of T. solium, T. saginata, and T. asiatica labeled with fluorescein isothiocyanate (FITC), digoxigenin (DIG), and tetramethylrhodamine (TAMRA), respectively, and biotin-labeled backward inner primers were used in mLAMP. The mLAMP assay succeeded in specific amplification of each respective target gene in a single tube. Furthermore, the mLAMP product from each species was easily distinguished by dot-ELISA with an antibody specific for FITC, DIG, or TAMRA. The mLAMP assay in combination with dot-ELISA will make identification of human Taenia species simpler, easier, and more practical. © The American Society of Tropical Medicine and Hygiene.

  19. Simple Identification of Human Taenia Species by Multiplex Loop-Mediated Isothermal Amplification in Combination with Dot Enzyme-Linked Immunosorbent Assay

    Science.gov (United States)

    Nkouawa, Agathe; Sako, Yasuhito; Okamoto, Munehiro; Ito, Akira

    2016-01-01

    For differential detection of Taenia solium, Taenia saginata, and Taenia asiatica, loop-mediated isothermal amplification (LAMP) assay targeting the cytochrome c oxidase subunit 1 gene has been recently developed and shown to be sensitive, specific, and effective. However, to achieve differential identification, one specimen requires three reaction mixtures containing a primer set of each Taenia species separately, which is complex and time consuming and increases the risk of cross-contamination. In this study, we developed a simple differential identification of human Taenia species using multiplex LAMP (mLAMP) in combination with dot enzyme-linked immunosorbent assay (dot-ELISA). Forward inner primers of T. solium, T. saginata, and T. asiatica labeled with fluorescein isothiocyanate (FITC), digoxigenin (DIG), and tetramethylrhodamine (TAMRA), respectively, and biotin-labeled backward inner primers were used in mLAMP. The mLAMP assay succeeded in specific amplification of each respective target gene in a single tube. Furthermore, the mLAMP product from each species was easily distinguished by dot-ELISA with an antibody specific for FITC, DIG, or TAMRA. The mLAMP assay in combination with dot-ELISA will make identification of human Taenia species simpler, easier, and more practical. PMID:27044566

  20. Development and application of an indirect enzyme-linked immunosorbent assay using recombinant truncated Cap protein for the diagnosis of porcine circovirus-like virus P1.

    Science.gov (United States)

    Wen, Li-bin; Wen, Shi-fu; He, Kong-wang

    2016-01-19

    Porcine circovirus-like virus P1 is a newly discovered virus. To date, there has been no specific serological assay for use in the diagnosis of P1 infection. Because P1 has high homology to porcine circovirus type 2 (PCV2) at the nucleotide level, the C-terminal portion of the capsid protein (amino acids 73-114), a discriminative antigen, was expressed in a prokaryotic expression system. The recombinant product (rctCap), composed of three identical repeated domains, was shown to be strongly immunoreactive to P1-specific serum. This assay was validated by comparison with an indirect immunofluorescence assay (IFA). The diagnostic sensitivity and specificity of the rctCap enzyme-linked immunosorbent assay (ELISA) developed in this study are 93.6% and 98.3%, respectively, compared with the results from IFAs on 450 sera samples from pigs. The indirect ELISA that we developed with rctCap, the recombinant capsid fragment containing the 217-342 nt repeat domain, was sensitive, specific, and suitable for the large-scale detection of P1 infections in swine.

  1. Enzyme-linked immunosorbent assay (ELISA) for the detection of use of the synthetic cannabinoid agonists UR-144 and XLR-11 in human urine.

    Science.gov (United States)

    Mohr, Amanda L A; Ofsa, Bill; Keil, Alyssa Marie; Simon, John R; McMullin, Matthew; Logan, Barry K

    2014-09-01

    Ongoing changes in the synthetic cannabinoid drug market create the need for relevant targeted immunoassays for rapid screening of biological samples. We describe the validation and performance characteristics of an enzyme-linked immunosorbent assay designed to detect use of one of the most prevalent synthetic cannabinoids in urine, UR-144, by targeting its pentanoic acid metabolite. Fluorinated UR-144 (XLR-11) has been demonstrated to metabolize to this common product. The assay has significant cross-reactivity with UR-144-5-OH, UR-144-4-OH and XLR-11-4-OH metabolites, but assay's cutoff is 5 ng/mL relative to the pentanoic acid metabolite of UR-144, which is used as the calibrator. The method was validated with 90 positive and negative control urine samples for UR-144, XLR-11 and its metabolites tested versus liquid chromatography-tandem mass spectrometry. The accuracy, sensitivity and specificity were determined to be 100% for the assay at the specified cutoff. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  2. Competitive Enzyme-Linked Immunosorbent Assay Based on a Rhoptry-Associated Protein 1 Epitope Specifically Identifies Babesia bovis-Infected Cattle

    Science.gov (United States)

    Goff, Will L.; McElwain, Terry F.; Suarez, Carlos E.; Johnson, Wendell C.; Brown, Wendy C.; Norimine, Junzo; Knowles, Donald P.

    2003-01-01

    The competitive enzyme-linked immunosorbent assay (cELISA) format has proven to be an accurate, reliable, easily standardized, and high-throughput method for detecting hemoparasite infections. In the present study, a species-specific, broadly conserved, and tandemly repeated B-cell epitope within the C terminus of the rhoptry-associated protein 1 of the hemoparasite Babesia bovis was cloned and expressed as a histidine-tagged thioredoxin fusion peptide and used as antigen in a cELISA. The assay was optimized with defined negative and positive bovine sera, where positive sera inhibited the binding of the epitope-specific monoclonal antibody BABB75A4. The cELISA accurately differentiated animals with B. bovis-specific antibodies from uninfected animals and from animals with antibodies against other tick-borne hemoparasites (98.7% specificity). In addition, B. bovis-specific sera from Australia, Argentina, Bolivia, Puerto Rico, and Morocco inhibited the binding of BABB75A4, confirming conservation of the epitope. The assay first detected experimentally infected animals between 13 and 17 days postinfection, and with sera from naturally infected carrier cattle, was comparable to indirect immunofluorescence (98.3% concordance). The assay appears to have the characteristics necessary for an epidemiologic and disease surveillance tool. PMID:12522037

  3. Comparison of Bovine coronavirus-specific and Bovine respiratory syncytial virus-specific antibodies in serum versus milk samples detected by enzyme-linked immunosorbent assay.

    Science.gov (United States)

    Ohlson, Anna; Blanco-Penedo, Isabel; Fall, Nils

    2014-01-01

    Bovine coronavirus (BCV; Betacoronavirus 1) and Bovine respiratory syncytial virus (BRSV) are significant causes of enteric and respiratory disease in beef and dairy cattle throughout the world. Indirect enzyme-linked immunosorbent assays are widely used to detect serum antibodies for herd monitoring and prevalence studies. In dairy herds, milk is more readily collected than serum. Hence, in order to investigate the test agreement between serum and milk, both serum and milk samples from 105 cows in 27 dairy herds were analyzed in parallel for presence of immunoglobulin G antibodies to BCV and BRSV. The Bland-Altman analyses of data demonstrated good agreement between serum and milk antibody titers for both viruses. The results indicate milk samples are sufficient for surveillance of antibodies to BCV and BRSV.

  4. Detection of Candida albicans Sap2 in cancer patient serum samples by an indirect competitive enzyme-linked immunosorbent assay for the diagnosis of candidiasis

    Directory of Open Access Journals (Sweden)

    Yicun Wang

    2013-01-01

    Full Text Available Background: The secreted aspartyl proteinases 2 (Sap2 of Candida albicans (C. albicans is a potential marker of candididasis. It is a virulence factor associated with adherence and tissue invasion. Aim: In order to detect Sap2 in clinical sera, we developed an indirect competitive enzyme-linked immunosorbent assay (ELISA. Materials and Methods: Polyclonal antibodies were produced for Sap2 by injecting Sap2 into a New Zealand White inbred rabbit. They could be used at a dilution exceeding 1:1200 in an indirect ELISA, and detected Sap2 concentration up to 1 ng/mL. Results: Of the 286 cancer serum samples tested, 16.8% were found as candidiasis. The test was simple and economical to perform and had a level of sensitivity for detection of low-titer positive sera; thus, it may be proven to be of value in epidemiological studies on candidiasis.

  5. Detection of Candida albicans Sap2 in cancer patient serum samples by an indirect competitive enzyme-linked immunosorbent assay for the diagnosis of candidiasis.

    Science.gov (United States)

    Wang, Yicun; Gao, Xiang; Zhi Gang, J U; Liu, Jingyuan; Dong, Shuai; Wang, Li

    2013-01-01

    The secreted aspartyl proteinases 2 (Sap2) of Candida albicans (C. albicans) is a potential marker of candididasis. It is a virulence factor associated with adherence and tissue invasion. In order to detect Sap2 in clinical sera, we developed an indirect competitive enzyme-linked immunosorbent assay (ELISA). Polyclonal antibodies were produced for Sap2 by injecting Sap2 into a New Zealand White inbred rabbit. They could be used at a dilution exceeding 1:1200 in an indirect ELISA, and detected Sap2 concentration up to 1 ng/mL. Of the 286 cancer serum samples tested, 16.8% were found as candidiasis. The test was simple and economical to perform and had a level of sensitivity for detection of low-titer positive sera; thus, it may be proven to be of value in epidemiological studies on candidiasis.

  6. Seroprevalence study of Equine rhinitis B virus (ERBV) in Australian weanling horses using serotype-specific ERBV enzyme-linked immunosorbent assays.

    Science.gov (United States)

    Horsington, Jacquelyn; Hartley, Carol A; Gilkerson, James R

    2013-09-01

    Respiratory infections are a major burden in the performance horse industry. Equine rhinitis B virus (ERBV) has been isolated from horses displaying clinical respiratory disease, and ERBV-neutralizing antibodies have been detected in 50-80% of horses in reported surveys. Current ERBV isolation and detection methods may underestimate the number of ERBV-positive animals and do not identify multiple serotype infections. The aim of the current study was to develop a serotyping ERBV antibody-detection enzyme-linked immunosorbent assay (ELISA) and examine the seroprevalence of ERBV in a group of Australian weanling horses. ELISAs with high sensitivity and specificity were developed. The seroprevalence of ERBV in the weanling horses was high (74-86%); ERBV-3 antibodies were most prevalent (58-62%) and ERBV-2 antibodies were least prevalent (10-16%). Many horses were seropositive to 2 or more serotypes. All 3 serotypes of ERBV were detected, and concurrent positivity to multiple serotypes was common.

  7. An electric detection of immunoglobulin G in the enzyme-linked immunosorbent assay using an indium oxide nanoparticle ion-sensitive field-effect transistor

    International Nuclear Information System (INIS)

    Lee, Dongjin; Cui, Tianhong

    2012-01-01

    Semiconducting nanoparticle ion-sensitive field-effect transistors (ISFETs) are used to detect immunoglobulin G (IgG) in the conventional enzyme-linked immunosorbent assay (ELISA). Indium oxide and silica nanoparticles were layer-by-layer self-assembled with the oppositely charged polyelectrolyte as the electrochemical transducer and antibody immobilization site, respectively. The assay was conducted on a novel platform of indium oxide nanoparticle ISFETs, where the electric signals are generated in response to the concentration of target IgG using the labeled detecting antibody. The sandwiched ELISA structure catalyzed the conversion of the acidic substrate into neutral substance with the aid of horseradish peroxidase. The pH change in the substrate solution was detected by nanoparticle ISFETs. Normal rabbit IgG was used as a model antigen whose detection limit of 0.04 ng ml −1 was found. The facile electric detection in the conventional assay through the semiconducting nanoparticle ISFET has potential applications as a point-of-care detection or a sensing element in a lab-on-a-chip system

  8. An Evaluation Study of Enzyme-Linked Immunosorbent Assay (ELISA) Using Recombinant Protein Pap31 for Detection of Antibody against Bartonella bacilliformis Infection among the Peruvian Population

    Science.gov (United States)

    Angkasekwinai, Nasikarn; Atkins, Erin H.; Romero, Sofia; Grieco, John; Chao, Chien Chung; Ching, Wei Mei

    2014-01-01

    Reliable laboratory testing is of great importance to detect Bartonella bacilliformis infection. We evaluated the sensitivity and specificity of the enzyme-linked immunosorbent assay (ELISA) using recombinant protein Pap31 (rPap31) for the detection of antibodies against B. bacilliformis as compared with immunofluorescent assay (IFA). Of the 302 sera collected between 1997 and 2000 among an at-risk Peruvian population, 103 and 34 samples tested positive for IFA-immunoglobulin G (IgG) and IFA-IgM, respectively. By using Youden's index, the cutoff values of ELISA-IgG at 0.915 gave a sensitivity of 84.5% and specificity of 94%. The cutoff values of ELISA-IgM at 0.634 gave a sensitivity of 88.2% and specificity of 85.1%. Using latent class analysis, estimates of sensitivity and specificity of almost all the assays were slightly higher than those of a conventional method of calculation. The test is proved beneficial for discriminating between infected and non-infected individuals with the advantage of low-cost and high-throughput capability. PMID:24515944

  9. Comparison of Laboratory-Developed and Commercial Monoclonal Antibody-Based Sandwich Enzyme-Linked Immunosorbent Assays for Almond (Prunus dulcis) Detection and Quantification.

    Science.gov (United States)

    Liu, Changqi; Chhabra, Guneet S; Zhao, Jing; Zaffran, Valerie D; Gupta, Sahil; Roux, Kenneth H; Gradziel, Thomas M; Sathe, Shridhar K

    2017-10-01

    A commercially available monoclonal antibody (mAb)-based direct sandwich enzyme-linked immunosorbent assay (ELISA) kit (BioFront Technologies, Tallahassee, Fla., U.S.A.) was compared with an in-house developed mAb 4C10-based ELISA for almond detection. The assays were comparable in sensitivity (limit of detection almond, limit of quantification almond), specificity (no cross-reactivity with 156 tested foods at a concentration of 100000 ppm whole sample), and reproducibility (intra- and interassay variability almond seeds subjected to autoclaving, blanching, frying, microwaving, and dry roasting. The almond recovery ranges for spiked food matrices were 84.3% to 124.6% for 4C10 ELISA and 81.2% to 127.4% for MonoTrace ELISA. The almond recovery ranges for commercial and laboratory prepared foods with declared/known almond amount were 30.9% to 161.2% for 4C10 ELISA and 38.1% to 207.6% for MonoTrace ELISA. Neither assay registered any false-positive or negative results among the tested commercial and laboratory prepared samples. Ability to detect and quantify trace amounts of almonds is important for improving safety of almond sensitive consumers. Two monoclonal antibody-based ELISAs were compared for almond detection. The information is useful to food industry, regulatory agencies, scientific community, and almond consumers. © 2017 Institute of Food Technologists®.

  10. How-to-do-it: Immunological Assays for the Classroom 1. Enzyme Linked Immunosorbent Assay (ELISA): A Laboratory Tool for Demonstration of Antibody-Antigen Interaction.

    Science.gov (United States)

    Russo, A. J.; And Others

    1984-01-01

    Background information, list of required materials, and procedures are provided for an immunological assay which has been modified for use as a classroom/laboratory demonstration of antigen-antibody reaction. The assay is designed for a two and one-half hour laboratory period but may be modified for one hour laboratories. (JN)

  11. Glypican-3 level assessed by the enzyme-linked immunosorbent assay is inferior to alpha-fetoprotein level for hepatocellular carcinoma diagnosis.

    Science.gov (United States)

    Jeon, Yejoo; Jang, Eun Sun; Choi, Yun Suk; Kim, Jin-Wook; Jeong, Sook-Hyang

    2016-09-01

    Glypican-3 (GPC3) protein is highly expressed in hepatocellular carcinoma (HCC) tissue. It has been suggested as a diagnostic biomarker, but its inconsistent performance means that it requires further assessment. We therefore investigated the diagnostic value of the plasma GPC3 level compared to the alpha-fetoprotein (AFP) level as a diagnostic biomarker of HCC. We enrolled 157 consecutive patients with newly diagnosed HCC and 156 patients with liver cirrhosis (LC) as the control group. GPC3 plasma levels were measured using two commercially available enzyme-linked immunosorbent assays (ELISAs, named as Assay 1 and 2), and AFP levels were measured using an enzyme-linked chemiluminescent immunoassay. The diagnostic accuracy was analyzed using the receiver operating characteristics (ROC) curve. Plasma GPC3 levels in HCC patients were very low (0-3.09 ng/mL) in Assay 1, while only 3 of the 157 patients (1.9%) showed detectable GPC3 levels in Assay 2. The median GPC3 level was not significantly elevated in the HCC group (0.80 ng/mL) compared with the LC group (0.60 ng/mL). The area under the ROC curve (AUC) for GPC3 was 0.559 in Assay 1. In contrast, the median AFP level was significantly higher in HCC (27.72 ng/mL) than in LC (4.74 ng/mL), with an AUC of 0.729. The plasma level of GPC3 is a poor diagnostic marker for HCC, being far inferior to AFP. The development of a consistent detection system for the blood level of GPC3 is warranted.

  12. Evaluation of a Cordia-IC enzyme-linked immunosorbent assay kit for the detection of circulating immune complexes.

    Science.gov (United States)

    Landoy, Z; West, T E; Vladutiu, A O; Fitzpatrick, J E

    1985-01-01

    A commercial kit (Cordia-IC) from Cordis Laboratory, Miami, Fla., was compared with the Raji cell radioimmunoassay for its ability to detect circulating immune complexes (CIC) in sera from 30 control subjects and 118 patients with infectious diseases. The 118 patients were categorized into the following groups: (i) 23 patients with bacterial endocarditis, (ii) 41 patients with bacteremia from an infected intravascular catheter or access device, and (iii) 54 patients with Staphylococcus aureus bacteremia related to a deep tissue infection. The Cordia-IC was comparable to the Raji cell radioimmunoassay in intraassay variability (4.0 versus 8.0%) and interassay reproducibility (8.7 versus 20.0%). Neither assay found CIC amounts above 12.5 micrograms equivalents (eq) of aggregated human gamma globulin (AHG) per ml in any of the 30 control individuals. In group 1, Cordia-IC detected 19 of 23 positives (mean, 73.6 micrograms eq of AHG per ml), whereas the Raji cell detected 16 of 23 positives (mean, 54.8 micrograms eq of AHG per ml). In group 2, Cordia-IC detected 19 of 41 positives (mean, 20.6 micrograms eq of AHG per ml), whereas the Raji cell detected 16 of 41 positives (mean, 15.1 micrograms eq of AHG per ml). In group 3, Cordia-IC found 38 of 54 positives (mean, 28.0 micrograms eq of AHG per ml), whereas the Raji cell found 32 of 54 positives (mean, 23.9 micrograms eq of AHG per ml). Statistically, these findings were not significantly different in any of the three patient groups (P> 0.15), and there was an overall good correlation between the results obtained by the two assays (r+0.64, PCordia-IC provided a suitable assay for the detection of CIC and might find application in routine clinical laboratories. PMID:3897269

  13. Diagnostic specificity of the African swine fever virus antibody detection enzyme-linked immunosorbent assay in feral and domestic pigs in the United States.

    Science.gov (United States)

    Bergeron, H C; Glas, P S; Schumann, K R

    2017-12-01

    African swine fever (ASF) is a highly contagious haemorrhagic disease of pigs that has the potential to cause mortality nearing 100% in naïve animals. While an outbreak of ASF in the United States' pig population (domestic and feral) has never been reported, an introduction of the disease has the potential to cause devastation to the pork industry and food security. During the recovery phase of an outbreak, an antibody detection diagnostic assay would be required to prove freedom of disease within the previously infected zone and eventually nationwide. Animals surviving an ASF infection would be considered carriers and could be identified through the persistence of ASF viral antibodies. These antibodies would demonstrate exposure to the disease and not vaccination, as there is no ASF vaccine available. A well-established commercial enzyme-linked immunosorbent assay (ELISA) detects antibodies against ASF virus (ASFV), but the diagnostic specificity of the assay had not been determined using serum samples from the pig population of the United States. This study describes an evaluation of the World Organization for Animal Health (OIE)-recommended Ingezim PPA COMPAC ELISA using a comprehensive cohort (n = 1791) of samples collected in the United States. The diagnostic specificity of the assay was determined to be 99.4% (95% confidence interval (CI): [98.9, 99.7]). The result of this study fills a gap in understanding the performance of the Ingezim PPA COMPAC ELISA in the ASF naïve pig population of the United States. Published 2017. This article is a U.S. Government work and is in the public domain in the USA.

  14. Application of 3D Printing Technology in Increasing the Diagnostic Performance of Enzyme-Linked Immunosorbent Assay (ELISA for Infectious Diseases

    Directory of Open Access Journals (Sweden)

    Harpal Singh

    2015-07-01

    Full Text Available Enzyme-linked Immunosorbent Assay (ELISA-based diagnosis is the mainstay for measuring antibody response in infectious diseases and to support pathogen identification of potential use in infectious disease outbreaks and clinical care of individual patients. The development of laboratory diagnostics using readily available 3D printing technologies provides a timely opportunity for further expansion of this technology into immunodetection systems. Utilizing available 3D printing platforms, a ‘3D well’ was designed and developed to have an increased surface area compared to those of 96-well plates. The ease and rapidity of the development of the 3D well prototype provided an opportunity for its rapid validation through the diagnostic performance of ELISA in infectious disease without modifying current laboratory practices for ELISA. The improved sensitivity of the 3D well of up to 2.25-fold higher compared to the 96-well ELISA provides a potential for the expansion of this technology towards miniaturization and Lab-On-a-Chip platforms to reduce time, volume of reagents and samples needed for such assays in the laboratory diagnosis of infectious and other diseases including applications in other disciplines.

  15. Development of an enzyme-linked immunosorbent assay-based method for measuring galactosyltransferase activity using a synthetic glycopolymer acceptor substrate.

    Science.gov (United States)

    Oubihi, M; Kitajima, K; Kobayashi, K; Adachi, T; Aoki, N; Matsuda, T

    1998-03-15

    A lectin-assisted enzyme-linked immunosorbent assay (ELISA)-based method using a synthetic glycopolymer as an acceptor substrate was developed for measuring beta 1,4-galactosyltransferase (GalT) activity. A polyacrylamide derivative having a beta-linked N-acetylglucosamine (GlcNAc beta) moiety on each monomeric unit was synthesized chemically and immobilized on a polystyrene microtiter plate as an acceptor substrate for GalT. After the plate was incubated with bovine GalT, the enzyme reaction product, beta-linked Gal residue on the polyacrylamide-bound GlcNAc residue, was detected by using Ricinus communis agglutinin 1 (RCA1), rabbit anti-RCA1 antibody, and a peroxidase-labeled anti-rabbit IgG. The lowest GalT concentration detectable by this method was about 0.5 mU/ml, which is comparable to those by the previously reported ELISA-based assays. The unique property of the glycopolymer, PAP(GlcNAc beta), of binding noncovalently but tightly to the polystyrene microtiter plate allowed the use of this acceptor substrate for the GalT activity measurement even in the presence of 1% Triton CF-54 and X-100. Our system was successfully applied to assess GalT activity in milk of various mammals.

  16. Development of cathepsin-L cysteine proteinase based Dot-enzyme-linked immunosorbent assay for the diagnosis of Fasciola gigantica infection in buffaloes.

    Science.gov (United States)

    Varghese, Anju; Raina, O K; Nagar, Gaurav; Garg, Rajat; Banerjee, P S; Maharana, B R; Kollannur, Justin D

    2012-02-10

    Native cathepsin-L cysteine proteinase (28 kDa) was purified from the excretory secretory products of Fasciola gigantica and was used for sero-diagnosis of F. gigantica infection in buffaloes by Dot-enzyme-linked immunosorbent assay (Dot-ELISA). The test detected F. gigantica field infection in these animals with a sensitivity of ∼ 90%. No specific IgG antibody binding was displayed by sera obtained from 76 buffaloes considered to be Fasciola and other parasite-free by microscopic examination of faeces and necropsy examination of liver, rumen and intestine. Additionally, sera from 156 Fasciola-free buffaloes, yet infected with Gigantocotyle explanatum, Paramphistomum epiclitum, Gastrothylax spp., Strongyloides papillosus and hydatid cyst were all negative, indicating that F. gigantica cathepsin-L cysteine proteinase does not cross-react with these helminth parasites in natural infection of the host. The data indicated that cathepsin-L cysteine proteinase based Dot-ELISA reached ∼ 90% sensitivity and 100% specificity with relation to above parasites in the detection of bubaline fasciolosis. The present Dot-ELISA diagnostic assay is relevant to the field diagnosis of F. gigantica infection in buffaloes. Copyright © 2011 Elsevier B.V. All rights reserved.

  17. Epitope-blocking enzyme-linked immunosorbent assay to differentiate west nile virus from Japanese encephalitis virus infections in equine sera.

    Science.gov (United States)

    Kitai, Yoko; Shoda, Mizue; Kondo, Takashi; Konishi, Eiji

    2007-08-01

    West Nile virus (WNV) is now widely distributed worldwide, except in most areas of Asia where Japanese encephalitis virus (JEV) is distributed. Considering the movement and migration of reservoir birds, there is concern that WNV may be introduced in Asian countries. Although manuals and guidelines for serological tests have been created in Japan in preparedness for the introduction of WNV, differential diagnosis between WNV and JEV may be complicated by antigenic cross-reactivities between these flaviviruses. Here, we generated a monoclonal antibody specific for the nonstructural protein 1 (NS1) of WNV and established an epitope-blocking enzyme-linked immunosorbent assay that can differentiate WNV from JEV infections in horse sera. Under conditions well suited for our assay system, samples collected from 95 horses in Japan (regarded as negative for WNV antibodies), including those collected from horses naturally infected with JEV, showed a mean inhibition value of 8.2% and a standard deviation (SD) of 6.5%. However, inhibition values obtained with serum used as a positive control (obtained after 28 days from a horse experimentally infected with WNV) in nine separate experiments showed a mean of 54.4% and an SD of 7.1%. We tentatively determined 27.6% (mean + 3 x SD obtained with 95 negative samples) as the cutoff value to differentiate positive from negative samples. Under this criterion, two horses experimentally infected with WNV were diagnosed as positive at 12 and 14 days, respectively, after infection.

  18. Application of 3D Printing Technology in Increasing the Diagnostic Performance of Enzyme-Linked Immunosorbent Assay (ELISA) for Infectious Diseases

    Science.gov (United States)

    Singh, Harpal; Shimojima, Masayuki; Shiratori, Tomomi; An, Le Van; Sugamata, Masami; Yang, Ming

    2015-01-01

    Enzyme-linked Immunosorbent Assay (ELISA)-based diagnosis is the mainstay for measuring antibody response in infectious diseases and to support pathogen identification of potential use in infectious disease outbreaks and clinical care of individual patients. The development of laboratory diagnostics using readily available 3D printing technologies provides a timely opportunity for further expansion of this technology into immunodetection systems. Utilizing available 3D printing platforms, a ‘3D well’ was designed and developed to have an increased surface area compared to those of 96-well plates. The ease and rapidity of the development of the 3D well prototype provided an opportunity for its rapid validation through the diagnostic performance of ELISA in infectious disease without modifying current laboratory practices for ELISA. The improved sensitivity of the 3D well of up to 2.25-fold higher compared to the 96-well ELISA provides a potential for the expansion of this technology towards miniaturization and Lab-On-a-Chip platforms to reduce time, volume of reagents and samples needed for such assays in the laboratory diagnosis of infectious and other diseases including applications in other disciplines. PMID:26184194

  19. Application of commercial enzyme linked immunosorbent assays (ELISA for the detection of antibodies for foot-and-mouth disease virus in wild boar and red deer

    Directory of Open Access Journals (Sweden)

    Terzić Svjetlana

    2012-01-01

    Full Text Available For detecting antibodies towards foot and mouth (FMD virus in sera collected from red deer hinds (Cervus elaphus and wild boars (Sus scrofa, three commercially available enzyme-linked immunosorbent assays (ELISA were used. Two ELISA kits (PrioCHECK FMDV NS and CHEKIT FMD-3ABC were used for the detection of antibodies towards non-structural proteins of FMD virus and one assay was based on the detection of antibodies for serotype O (PrioCHECK FMDV type O. All of the sera tested in our study were negative for antibodies against FMD virus. The aim of this study was to investigate the usefulness of commercially available ELISA kits given for marketing authorization in Croatia in testing the prevalence of FMD antibodies in wild boar and red deer populations. Since the producers of ELISA kits used in our study did not declare wild animals as a target species, we hypothesised that the same kits could be used for serological diagnosis of FMD in red deer and wild boars. Our study confirmed that the kits used are acceptable for detecting antibodies in both species tested, however, the investigation highlighted the problem of validating the kits due to the absence of available positive sera originating from red deer, as well as other susceptible species, especially artiodactyls.

  20. Application of 3D Printing Technology in Increasing the Diagnostic Performance of Enzyme-Linked Immunosorbent Assay (ELISA) for Infectious Diseases.

    Science.gov (United States)

    Singh, Harpal; Shimojima, Masayuki; Shiratori, Tomomi; An, Le Van; Sugamata, Masami; Yang, Ming

    2015-07-08

    Enzyme-linked Immunosorbent Assay (ELISA)-based diagnosis is the mainstay for measuring antibody response in infectious diseases and to support pathogen identification of potential use in infectious disease outbreaks and clinical care of individual patients. The development of laboratory diagnostics using readily available 3D printing technologies provides a timely opportunity for further expansion of this technology into immunodetection systems. Utilizing available 3D printing platforms, a '3D well' was designed and developed to have an increased surface area compared to those of 96-well plates. The ease and rapidity of the development of the 3D well prototype provided an opportunity for its rapid validation through the diagnostic performance of ELISA in infectious disease without modifying current laboratory practices for ELISA. The improved sensitivity of the 3D well of up to 2.25-fold higher compared to the 96-well ELISA provides a potential for the expansion of this technology towards miniaturization and Lab-On-a-Chip platforms to reduce time, volume of reagents and samples needed for such assays in the laboratory diagnosis of infectious and other diseases including applications in other disciplines.

  1. Iodoacetyl-functionalized pullulan: A supplemental enhancer for single-domain antibody-polyclonal antibody sandwich enzyme-linked immunosorbent assay for detection of survivin.

    Science.gov (United States)

    Matsushita, Takahiko; Arai, Hidenao; Koyama, Tetsuo; Hatano, Ken; Nemoto, Naoto; Matsuoka, Koji

    2017-11-01

    Survivin, an inhibitor of the apoptosis protein family, is a potent tumor marker for diagnosis and prognosis. The enzyme-linked immunosorbent assay (ELISA) is one of the methods that has been used for detection of survivin. However, ELISA has several disadvantages caused by the use of conventional antibodies, and we have therefore been trying to develop a novel ELISA system using camelid single-domain antibodies (VHHs) as advantageous replacements. Here we report a supplemental approach to improve the VHH-polyclonal antibody sandwich ELISA for survivin detection. Iodoacetyl-functionalized pullulan was synthesized, and its thiol reactivity was characterized by a model reaction with l-cysteine. The thiophilic pullulan was applied to an immunoassay asan additive upon coating of standard assay plates with an anti-survivin VHH fusion protein with C-terminal cysteine. The results showed that the mole ratio of the additive to VHH had a significant effect on the consequent response. Mole ratios of 0.07, 0.7, and 7 led to 90% lower, 15% higher, and 69% lower responses, respectively, than the response of a positive control in which no additive was used. The background levels observed in any additive conditions were as low as that of a negative control lacking both VHH and the additive. These results indicate the applicability of the thiol-reactive pullulan as a response enhancer to VHH-based ELISA. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Development and Application of an Indirect Enzyme-Linked Immunosorbent Assay Using Recombinant Mag1 for Serodiagnosis of Toxoplasma gondii In Dogs.

    Science.gov (United States)

    Zhuo, Xunhui; Sun, Hongchao; Zhang, Zhi; Luo, Jiaqing; Shan, Ying; Du, Aifang

    2017-06-01

    Serologic tests are widely accepted and applied as means to detect anti- Toxoplasma gondii immunoglobulin G antibodies. In this study, recombinant matrix antigen (rMAG1) was induced by isopropyl-β-d-thiogalactoside and purified by nickel-nitrilotriacetic acid purification system. We then developed and optimized an indirect enzyme-linked immunosorbent assay (ELISA) through checkerboard assays using serial dilutions of antigens and sera to assess the potential use of rMAG1 in serologic detection of T. gondii infection in dogs. Serum samples from 93 domestic dogs were analyzed by western blot and rMAG1-ELISA. The results were compared with those obtained from an ELISA with the soluble Toxoplasma lysate antigens (TLA). We found that although yielding an excellent agreement (96.7%) with western blot data (κ = 0.9659), rMAG1-ELISA produced higher sensitivity (93.9% vs. 87.8%) and specificity (98.3% vs. 96.7%) than TLA-ELISA. In addition, receiver operating characteristic analysis also revealed that rMAG1-ELISA is in more agreement with western blot (area under the curve [AUC] = 0.985) relative to TLA-ELISA (AUC = 0.955). These results indicated that the rMAG1-ELISA established in this study provides a promising and reliable tool for serologic detection of T. gondii infection in dogs.

  3. Expression of sheep pathogen Babesia sp. Xinjiang rhoptry-associated protein 1 and evaluation of its diagnostic potential by enzyme-linked immunosorbent assay.

    Science.gov (United States)

    Niu, Qingli; Liu, Zhijie; Yang, Jifei; Yu, Peifa; Pan, Yuping; Zhai, Bintao; Luo, Jianxun; Guan, Guiquan; Yin, Hong

    2016-12-01

    Ovine babesiosis is one of the most important tick-borne haemoparasitic diseases of small ruminants. The ovine parasite Babesia sp. Xinjiang is widespread in China. In this study, recombinant full-length XJrRAP-1aα2 (rhoptry-associated protein 1aα2) and C-terminal XJrRAP-1aα2 CT of Babesia sp. Xinjiang were expressed and used to evaluate their diagnostic potential for Babesia sp. Xinjiang infections by indirect enzyme-linked immunosorbent assay (ELISA). Purified XJrRAP-1aα2 was tested for reactivity with sera from animals experimentally infected with Babesia sp. Xinjiang and other haemoparasites using Western blotting and ELISA. The results showed no cross-reactivities between XJrRAP-1aα2 CT and sera from animals infected by other pathogens. High level of antibodies against RAP-1a usually lasted 10 weeks post-infection (wpi). A total of 3690 serum samples from small ruminants in 23 provinces located in 59 different regions of China were tested by ELISA. The results indicated that the average positive rate was 30·43%, and the infections were found in all of the investigated provinces. This is the first report on the expression and potential use of a recombinant XJrRAP-1aα2 CT antigen for the development of serological assays for the diagnosis of ovine babesiosis, caused by Babesia sp. Xinjiang.

  4. Validation of an enzyme-linked immunosorbent assay (ELISA) for the measurement of canine S100A12.

    Science.gov (United States)

    Heilmann, Romy M; Cranford, Shannon M; Ambrus, Andy; Grützner, Niels; Schellenberg, Stefan; Ruaux, Craig G; Suchodolski, Jan S; Steiner, Jörg M

    2016-03-01

    Canine S100 calcium-binding protein A12 (cS100A12) shows promise as biomarker of inflammation in dogs. A previously developed cS100A12-radioimmunoassay (RIA) requires radioactive tracers and is not sensitive enough for fecal cS100A12 concentrations in 79% of tested healthy dogs. An ELISA assay may be more sensitive than RIA and does not require radioactive tracers. The purpose of the study was to establish a sandwich ELISA for serum and fecal cS100A12, and to establish reference intervals (RI) for normal healthy canine serum and feces. Polyclonal rabbit anti-cS100A12 antibodies were generated and tested by Western blotting and immunohistochemistry. A sandwich ELISA was developed and validated, including accuracy and precision, and agreement with cS100A12-RIA. The RI, stability, and biologic variation in fecal cS100A12, and the effect of corticosteroids on serum cS100A12 were evaluated. Lower detection limits were 5 μg/L (serum) and 1 ng/g (fecal), respectively. Intra- and inter-assay coefficients of variation were ≤ 4.4% and ≤ 10.9%, respectively. Observed-to-expected ratios for linearity and spiking recovery were 98.2 ± 9.8% (mean ± SD) and 93.0 ± 6.1%, respectively. There was a significant bias between the ELISA and the RIA. The RI was 49-320 μg/L for serum and 2-484 ng/g for fecal cS100A12. Fecal cS100A12 was stable for 7 days at 23, 4, -20, and -80°C; biologic variation was negligible but variation within one fecal sample was significant. Corticosteroid treatment had no clinically significant effect on serum cS100A12 concentrations. The cS100A12-ELISA is a precise and accurate assay for serum and fecal cS100A12 in dogs. © 2016 American Society for Veterinary Clinical Pathology.

  5. DNA & Protein detection based on microbead agglutination

    KAUST Repository

    Kodzius, Rimantas

    2012-06-06

    We report a simple and rapid room temperature assay for point-of-care (POC) testing that is based on specific agglutination. Agglutination tests are based on aggregation of microparticles in the presence of a specific analyte thus enabling the macroscopic observation. Agglutination-based tests are most often used to explore the antibody-antigen reactions. Agglutination has been used for mode protein assays using a biotin/streptavidin two-component system, as well as a hybridization based two-component assay; however, as our work shows, two-component systems are prone to self-termination of the linking analyte and thus have a lower sensitivity. Three component systems have also been used with DNA hybridization, as in our work; however, their assay requires 48 hours for incubation, while our assay is performed in 5 minutes making it a real candidate for POC testing. We demonstrate three assays: a two-component biotin/streptavidin assay, a three-component hybridization assay using single stranded DNA (ssDNA) molecules and a stepped three-component hybridization assay. The comparison of these three assays shows our simple stepped three-component agglutination assay to be rapid at room temperature and more sensitive than the two-component version by an order of magnitude. An agglutination assay was also performed in a PDMS microfluidic chip where agglutinated beads were trapped by filter columns for easy observation. We developed a rapid (5 minute) room temperature assay, which is based on microbead agglutination. Our three-component assay solves the linker self-termination issue allowing an order of magnitude increase in sensitivity over two–component assays. Our stepped version of the three-component assay solves the issue with probe site saturation thus enabling a wider range of detection. Detection of the agglutinated beads with the naked eye by trapping in microfluidic channels has been shown.

  6. Moderate reagent mixing on an orbital shaker reduces the incubation time of enzyme-linked immunosorbent assay.

    Science.gov (United States)

    Kumar, Saroj; Ahirwar, Rajesh; Rehman, Ishita; Nahar, Pradip

    2017-07-01

    Rapid diagnostic tests can be developed using ELISA for detection of diseases in emergency conditions. Conventional ELISA takes 1-2 days, making it unsuitable for rapid diagnostics. Here, we report the effect of reagents mixing via shaking or vortexing on the assay timing of ELISA. A 48-min protocol of ELISA involving 12-min incubations with reagent mixing at 750 rpm for every step was optimized. Contrary to this, time-optimized control ELISA performed without mixing produced similar results in 8 h, leaving a time gain of 7 h using the developed protocol. Collectively, the findings suggest the development of ELISA-based rapid diagnostics. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Standardization of the indirect enzyme-linked immunosorbent assay for detection of antibodies against Newcastle disease virus in chickens

    International Nuclear Information System (INIS)

    Della Porta, A.J.; Young, J.; Hansson, E.; Spencer, T.

    1994-01-01

    Newcastle disease is the major viral disease of poultry causing significant economic losses in most countries except Australia and New Zealand. Serological monitoring of poultry has traditionally been carried out using the haemagglutinin-inhibition (HI) test. More recently, ELISA has been used for the same purpose. This paper described the use of an indirect ELISA for assay of antibodies in chickens against Newcastle disease viruses and compares some of the parameters for this test. The sucrose density gradient purified, inactivated, antigen enabled performance of the test without the addition of any blocking agents other than the usual Tween 20. A range of plates was compared and the most suitable plate was found to be a polystyrene haemagglutination plate giving an excellent positive to negative ratio of 33.2, compared with some expensive ELISA plates which gave very low +ve/-ve ratios. Various incubation conditions for the steps in the ELISA were compared and incubation with shaking at room temperature (24 to 28 deg. C) gave adequate reactivity whilst simplifying incubation conditions and speeding up the test. The negative cut-off value was determined by testing 1632 HI negative specific pathogen free sera from birds of a wide age range. The reactivity of sera in the ELISA was standardized using a standard curve on every plate and converting the readings to ELISA units (EUs) in the range of 16 to 512 EUs. The EU values of these sera were not normally distributed and so the 95% cut-off was determined by ranking the values in descending order and retaining only the top 5% of the values as false positives. This resulted in a cut-off value of 33.6 EUs, with few of HI positive sera having values lower than this cut-off. The use of a standard curve on each plate is recommended in order to standardize the assay and to determine the ELISA units for the test sera. (author). 14 refs, 2 figs, 1 tab

  8. A novel marker for assessment of liver matrix remodeling: An enzyme-linked immunosorbent assay (ELISA) detecting a MMP generated type I collagen neo-epitope (C1M)

    DEFF Research Database (Denmark)

    Leeming, Diana Julie; He, Y.; Veidal, S. S.

    2011-01-01

    A competitive enzyme-linked immunosorbent assay (ELISA) for detection of a type I collagen fragment generated by matrix metalloproteinases (MMP) -2, -9 and -13, was developed (CO1-764 or C1M). The biomarker was evaluated in two preclinical rat models of liver fibrosis: bile duct ligation (BDL) an...

  9. Enzyme-linked immunosorbent assay using a virus type-specific peptide based on a subdomain of envelope protein e(rns) for serologic diagnosis of pestivirus infections in swine

    NARCIS (Netherlands)

    Langedijk, J.P.; Middel, W.G.; Meloen, R.H.; Kramps, J.A.; Smit, de J.A.

    2001-01-01

    Peptides deduced from the C-terminal end (residues 191 to 227) of pestivirus envelope protein Erns were used to develop enzyme-linked immunosorbent assays (ELISAs) to measure specifically antibodies against different types of pestiviruses. The choice of the peptide was based on the modular structure

  10. Development and evaluation of a Sarcocystis neurona-specific IgM capture enzyme-linked immunosorbent assay.

    Science.gov (United States)

    Murphy, J E; Marsh, A E; Reed, S M; Meadows, C; Bolten, K; Saville, W J A

    2006-01-01

    Equine protozoal myeloencephalitis (EPM) is a serious neurologic disease of horses caused primarily by the protozoal parasite Sarcocystis neurona. Currently available antemortem diagnostic testing has low specificity. The hypothesis of this study was that serum and cerebrospinal fluid (CSF) of horses experimentally challenged with S neurona would have an increased S neurona-specific IgM (Sn-IgM) concentration after infection, as determined by an IgM capture enzyme linked immunoassay (ELISA). The ELISA was based on the S neurona low molecular weight protein SNUCD-1 antigen and the monoclonal antibody 2G5 labeled with horseradish peroxidase. The test was evaluated using serum and CSF from 12 horses experimentally infected with 1.5 million S neurona sporocysts and 16 horses experimentally infected with varying doses (100 to 100,000) of S neurona sporocysts, for which results of histopathologic examination of the central nervous system were available. For horses challenged with 1.5 million sporocysts, there was a significant increase in serum Sn-IgM concentrations compared with values before infection at weeks 2-6 after inoculation (P neurona, there were significant increases in serum Sn-IgM concentration at various points in time after inoculation, depending on the challenge dose (P < .01). In addition, there was a significant increase between the CSF Sn-IgM concentrations before and after inoculation (P < .0001). These results support further evaluation of the assay as a diagnostic test during the acute phase of EPM.

  11. Direct Agglutination Test and Enzyme Linked Immunosorbent Assay with Urine Samples for the Diagnosis of Visceral Leishma-niasis

    Directory of Open Access Journals (Sweden)

    Sarkari B

    2007-07-01

    Full Text Available Background: Visceral leishmaniasis (VL or Kala azar is an infectious disease caused by various species of Leishmania parasites. The aim of this study was to detect and compare the presence of anti-Leishmania antibodies in the urine of vis-ceral leishmaniasis patients using ELISA and DAT methods."nMethods: A total of 30 urine samples were collected from VL patients referred to Shiraz (southeast of Iran hospitals. Moreover 31 urine samples were collected from healthy individuals and patients with other diseases such as malaria, brucellosis, hydatidosis and cutaneous leishmaniasis. Collected samples were examined to detect anti-Leishmania antibod-ies in urine, using ELISA and DAT."nResults: Anti-Leishmania antibody was detected in urine of 18 out of 30 (60% VL patients by DAT while ELISA detected anti-Leishmania antibodies in urine of 28 out of 30 (93.3% of VL cases. Sensitivity and specificity of urine-based DAT was 60% and 83.9%, respectively while sensitivity and specificity of urine-based ELISA were 93.3% and 93.5%, corre-spondingly. "nConclusion: Urine-based DAT and ELISA have a reasonable specificity and sensitivity in diagnosis of VL. Accordingly, urine-based ELISA might be a suitable alternative for serum based assays for diagnosis of VL.

  12. Evaluation of Two Enzyme-Linked Immunosorbent Assay Kits for Chikungunya Virus IgM Using Samples from Deceased Organ and Tissue Donors

    Science.gov (United States)

    Altrich, Michelle L.; Nowicki, Marek J.

    2016-01-01

    The identification of nearly 3,500 cases of chikungunya virus (CHIKV) infection in U.S. residents returning in 2014 and 2015 from areas in which it is endemic has raised concerns within the transplant community that, should recently infected individuals become organ and/or tissue donors, CHIKV would be transmitted to transplant recipients. Thus, tests designed to detect recent CHIKV infection among U.S. organ and tissue donors may become necessary in the future. Accordingly, we evaluated 2 enzyme-linked immunosorbent assays (ELISAs) for CHIKV IgM readily available in the United States using 1,000 deidentified serum or plasma specimens collected from donors between November 2014 and March 2015. The Euroimmun indirect ELISA identified 38 reactive specimens; however, all 38 were negative for CHIKV IgG and IgM in immunofluorescence assays (IFAs) conducted at a reference laboratory and, thus, were falsely reactive in the Euroimmun CHIKV IgM assay. The InBios IgM-capture ELISA identified 26 reactive samples, and one was still reactive (index ≥ 1.00) when retested using the InBios kit with a background subtraction modification to identify false reactivity. This reactive specimen was CHIKV IgM negative but IgG positive by IFAs at two reference laboratories; plaque reduction neutralization testing (PRNT) demonstrated CHIKV-specific reactivity. The IgG and PRNT findings strongly suggest that the InBios CHIKV IgM-reactive result represents true reactivity, even though the IgM IFA result was negative. If testing organ/tissue donors for CHIKV IgM becomes necessary, the limitations of the currently available CHIKV IgM ELISAs and options for their optimization must be understood to avoid organ/tissue wastage due to falsely reactive results. PMID:27535838

  13. Validation of an enzyme-linked immunosorbent assay for the quantification of citrullinated histone H3 as a marker for neutrophil extracellular traps in human plasma.

    Science.gov (United States)

    Thålin, Charlotte; Daleskog, Maud; Göransson, Sophie Paues; Schatzberg, Daphne; Lasselin, Julie; Laska, Ann-Charlotte; Kallner, Anders; Helleday, Thomas; Wallén, Håkan; Demers, Mélanie

    2017-06-01

    There is an emerging interest in the diverse functions of neutrophil extracellular traps (NETs) in a variety of disease settings. However, data on circulating NETs rely largely upon surrogate NET markers such as cell-free DNA, nucleosomes, and NET-associated enzymes. Citrullination of histone H3 by peptidyl arginine deiminase 4 (PAD4) is central for NET formation, and citrullinated histone H3 (H3Cit) is considered a NET-specific biomarker. We therefore aimed to optimize and validate a new enzyme-linked immunosorbent assay (ELISA) to quantify the levels of H3Cit in human plasma. A standard curve made of in vitro PAD4-citrullinated histones H3 allows for the quantification of H3Cit in plasma using an anti-histone antibody as capture antibody and an anti-histone H3 citrulline antibody for detection. The assay was evaluated for linearity, stability, specificity, and precision on plasma samples obtained from a human model of inflammation before and after lipopolysaccharide injection. The results revealed linearity and high specificity demonstrated by the inability of detecting non-citrullinated histone H3. Coefficients of variation for intra- and inter-assay variability ranged from 2.1 to 5.1% and from 5.8 to 13.5%, respectively, allowing for a high precision. Furthermore, our results support an inflammatory induction of a systemic NET burden by showing, for the first time, clear intra-individual elevations of plasma H3Cit in a human model of lipopolysaccharide-induced inflammation. Taken together, our work demonstrates the development of a new method for the quantification of H3Cit by ELISA that can reliably be used for the detection of NETs in human plasma.

  14. Development and evaluation of an avian influenza, neuraminidase subtype 1, indirect enzyme-linked immunosorbent assay for poultry using the differentiation of infected from vaccinated animals control strategy.

    Science.gov (United States)

    Liu, Y; Mundt, E; Mundt, A; Sylte, M; Suarez, D L; Swayne, D E; García, M

    2010-03-01

    An indirect enzyme-linked immunosorbent assay (ELISA) was developed using baculovirus, purified, recombinant N1 protein from A/chicken/Indonesia/PA7/2003 (H5N1) virus. The N1-ELISA showed high selectivity for detection of N1 antibodies, with no cross-reactivity with other neuraminidase subtypes, and broad reactivity with sera to N1 subtype isolates from North American and Eurasian lineages. Sensitivity of the N1-ELISA to detect N1 antibodies in turkey sera, collected 3 wk after H1N1 vaccination, was comparable to detection of avian influenza antibodies by the commercial, indirect ELISAs ProFLOK AIV Plus ELISA Kit (Synbiotics, Kansas City, MO) and Avian Influenza Virus Antibody Test Kit (IDEXX, Westbrook, ME). However, 6 wk after vaccination, the Synbiotics ELISA kit performed better than the N1-ELISA and the IDEXX ELISA kit. An evaluation was made of the ability of the N1-ELISA to discriminate vaccinated chickens from subsequently challenged chickens. Two experiments were conducted, chickens were vaccinated with inactivated H5N2 and H5N9 viruses and challenged with highly pathogenic H5N1 virus, and chickens were vaccinated with recombinant poxvirus vaccine encoding H7 and challenged with highly pathogenic H7N1 virus. Serum samples were collected at 14 days postchallenge and tested by hemagglutination inhibition (HI), quantitative neuraminidase inhibition (NI), and N1-ELISA. At 2 days postchallenge, oropharyngeal swabs were collected for virus isolation (VI) to confirm infection. The N1-ELISA was in fair agreement with VI and HI results. Although the N1-ELISA showed a lower sensitivity than the NI assay, it was demonstrated that detection of N1 antibodies by ELISA was an effective and rapid assay to identify exposure to the challenge virus in vaccinated chickens. Therefore, N1-ELISA can facilitate a vaccination strategy with differentiation of infected from vaccinated animals using a neuraminidase heterologous approach.

  15. Development of an enzyme-linked immunosorbent assay for detection of CDCP1 shed from the cell surface and present in colorectal cancer serum specimens.

    Science.gov (United States)

    Chen, Yang; Harrington, Brittney S; Lau, Kevin C N; Burke, Lez J; He, Yaowu; Iconomou, Mary; Palmer, James S; Meade, Brian; Lumley, John W; Hooper, John D

    2017-05-30

    CUB domain containing protein 1 (CDCP1) is a transmembrane protein involved in progression of several cancers. When located on the plasma membrane, full-length 135kDa CDCP1 can undergo proteolysis mediated by serine proteases that cleave after two adjacent amino acids (arginine 368 and lysine 369). This releases from the cell surface two 65kDa fragments, collectively termed ShE-CDCP1, that differ by one carboxyl terminal residue. To evaluate the function of CDCP1 and its potential utility as a cancer biomarker, in this study we developed an enzyme-linked immunosorbent assay (ELISA) to reliably and easily measure the concentration of ShE-CDCP1 in biological samples. Using a reference standard we demonstrate that the developed ELISA has a working range of 0.68-26.5ng/ml, and the limit of detection is 0.25ng/ml. It displays high intra-assay (repeatability) and high inter-assay (reproducibility) precision with all coefficients of variation ≤7%. The ELISA also displays high accuracy detecting ShE-CDCP1 levels at ≥94.8% of actual concentration using quality control samples. We employed the ELISA to measure the concentration of ShE-CDCP1 in human serum samples with our results suggesting that levels are significantly higher in serum of colorectal cancer patients compared with serum from individuals with benign conditions (pELISA is a suitable method to quantify ShE-CDCP1 concentration in human serum. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Development of an enzyme-linked immunosorbent assay for seven sulfonamide residues and investigation of matrix effects from different food samples.

    Science.gov (United States)

    Zhang, Hongyan; Wang, Lei; Zhang, Yan; Fang, Guozhen; Zheng, Wenjie; Wang, Shuo

    2007-03-21

    Direct competitive enzyme-linked immunosorbent assays (ELISA) were developed to detect a broad range of sulfonamides in various matrices. Screening for this class of antibiotics in pig muscle, chicken muscle, fish, and egg extracts was accomplished by simple, rapid extraction methods carried out with only phosphate-buffered saline (PBS) buffer. Twenty milliliters of extract solution was added to 4 g of sample to extract the sulfonamide residues, and sample extracts diluted with assay buffer were directly analyzed by ELISA; matrix effects could be avoided with 1:5 dilution of pig muscle, chicken muscle, and egg extracts with PBS and 1:5 dilution of fish extract with 1% bovine serum albumin (BSA)-PBS. For liver sample, the extraction method was a little more complicated; 2 g of sample was added to 20 mL of ethanol, mixed, and then centrifuged. The solvent of 10 mL of the upper liquid was removed, and the residues were dissolved in 10 mL of PBS and then filtered; the filtrate was diluted two-fold with 0.5% BSA-PBS for ELISA. These common methods were able to detect seven sulfonamide residues such as sulfisozole, sulfathiazole, sufameter, sulfamethoxypyridazine, sulfapyridine, sulfamethizole, and sulfachlorpyridazine in pig muscle, liver, chicken muscle, egg, and fish. The assay's detection limits for these compounds were less than 100 microg kg-1. Various extraction methods were tested, and the average recovery (n=3) of 100 microg kg-1 for the matrices was found to range from 77.3 to 123.7%.

  17. Development of an Indirect Competitive Enzyme-Linked Immunosorbent Assay for Glycocholic Acid Based on Chicken Single-Chain Variable Fragment Antibodies.

    Science.gov (United States)

    Cui, Xiping; Vasylieva, Natalia; Wu, Panpan; Barnych, Bogdan; Yang, Jun; Shen, Ding; He, Qiyi; Gee, Shirley J; Zhao, Suqing; Hammock, Bruce D

    2017-10-17

    Glycocholic acid (GCA) is an important metabolite of bile acids, whose urine levels are expected to be a specific diagnostic biomarker for hepatocellular carcinoma (HCC). A high-throughput immunoassay for determination of GCA would be of significant advantage and useful for primary diagnosis, surveillance, and early detection of HCC. Single-chain variable fragment (scFv) antibodies have several desirable characteristics and are an attractive alternative to traditional antibodies for the immunoassay. Because chicken antibodies possess single heavy and light variable functional domains, they are an ideal framework for simplified generation of recombinant antibodies for GCA detection. However, chicken scFvs have rarely been used to detect GCA. In this study, a scFv library was generated from chickens immunized with a GCA hapten coupled to bovine serum albumin (BSA), and anti-GCA scFvs were isolated by a phage-displayed method. Compared to the homologous coating antigen, use of a heterologous coating antigen resulted in about an 85-fold improvement in sensitivity of the immunoassay. This assay, under optimized conditions, had a linear range of 0.02-0.18 μg/mL, with an IC 50 of 0.06 μg/mL. The assay showed negligible cross-reactivity with various related bile acids, except for taurocholic acid. The detection of GCA from spiked human urine samples ranged from 86.7% to 123.3%. These results, combined with the advantages of scFv antibodies, indicated that a chicken scFv-based enzyme-linked immunosorbent assay is a suitable method for high-throughput screening of GCA in human urine.

  18. The Effect of Different Methods of Fermentation on the Detection of Milk Protein Residues in Retail Cheese by Enzyme-Linked Immunosorbent Assay (ELISA).

    Science.gov (United States)

    Ivens, Katherine O; Baumert, Joseph L; Hutkins, Robert L; Taylor, Steve L

    2017-11-01

    Milk and milk products are among the most important allergenic food ingredients, both in the United States and throughout the world; cheeses are among the most important of these milk products. Milk contains several major antigenic proteins, each with differing susceptibilities to proteolytic enzymes. The extent of proteolysis in cheese varies as a result of conditions during manufacture and ripening. Proteolysis has the potential to degrade antigenic and allergenic epitopes that are important for residue detection and elicitation of allergic reactions. Commercial enzyme-linked immunosorbent assays (ELISAs) are not currently validated for use in detecting residues in hydrolyzed or fermented food products. Eighteen retail cheeses produced using 5 different styles of fermentation were investigated for detectable milk protein residues with 4 commercial ELISA kits. Mozzarella, Swiss, Blue, Limburger, and Brie cheeses were assessed. The Neogen Veratox® Casein and Neogen Veratox® Total Milk kits were capable of detecting milk residues in most cheeses evaluated, including blue-veined cheeses that exhibit extensive proteolysis. The other 2 ELISA kits evaluated, r-Biopharm® Fast Casein and ELISA Systems™ Casein, can detect milk residues in cheeses other than blue-veined varieties. ELISA results cannot be quantitatively compared among kits. The quantitative reliability of ELISA results in detection of cheese residues is questionable, but some methods are sufficiently robust to use as a semi-quantitative indication of proper allergen control for the validation of cleaning programs in industry settings. Many commercially available enzyme-linked immunosorbent assays (ELISAs) are not validated for detection of allergenic residues in fermented or hydrolyzed products. This research seeks to determine if commercial milk ELISAs can detect milk residues in varieties of cheese that have undergone different styles of fermentation and different degrees of proteolysis. Only certain

  19. Cross-validation of commercial enzyme-linked immunosorbent assay and radioimmunoassay for porcine C-peptide concentration measurements in non-human primate serum.

    Science.gov (United States)

    Gresch, Sarah C; Mutch, Lucas A; Janecek, Jody L; Hegstad-Davies, Rebecca L; Graham, Melanie L

    2017-09-01

    C-peptide concentration is widely used as a marker of insulin secretion and is especially relevant in evaluating islet graft function following transplantation, because its measurement is not confounded by the presence of exogenous insulin. To address the shortage of human islet donors, the use of porcine islets has been proposed as a possible solution and the stringent pig-to-non-human primate (NHP) model is often the most relevant for pre-clinical evaluation of the potential for diabetes reversal resulting from an islet xenograft. The Millipore radioimmunoassay (RIA) was exclusively used to measure porcine C-peptide (PCP) until 2013 when the assay was discontinued and subsequently a commercially available enzyme-linked immunosorbent assay (ELISA) from Mercodia has been widely adopted. Both assays have been used in pre-clinical trials evaluating the therapeutic potential of xenograft products in reversing diabetes in the pig-to-NHP model, to interpret data in a comparable way it may be useful to perform a harmonization of C-peptide measurements. We performed a method comparison by determining the PCP concentration in 620 serum samples collected from 20 diabetic cynomolgus macaques transplanted with adult porcine islets. All analyses were performed according to manufacturer instructions. With both assays, we demonstrated an acceptable detection limit, precision, and recovery. Linearity of the ELISA met acceptance criteria at all concentrations tested while linearity of the RIA only met acceptance criteria at five of the eight concentrations tested. The RIA had a detection limit of 0.16 ng/mL, and recovery ranged from 82% to 96% and met linearity acceptance criteria at 0.35 ng/mL and from 0.78 to 2.33 ng/mL. The ELISA had a detection limit of 0.03 ng/mL, and recovery ranged from 81% to 115% and met linearity acceptance criteria from 0.08 to 0.85 ng/mL. Both assays had intra-assay precision assay precision ELISA demonstrated a significant correlation with RIA (R

  20. Differentiation of foot-and-mouth disease virus-infected from vaccinated pigs by enzyme-linked immunosorbent assay using nonstructural protein 3AB as the antigen and application to an eradication program

    DEFF Research Database (Denmark)

    Chung, Wen Bin; Sørensen, Karl Johan; Liao, Pei Chih

    2002-01-01

    Baculovirus-expressed foot-and-mouth disease virus (FMDV) nonstructural protein 3AB was used as the antigen in an enzyme-linked immunosorbent assay. This assay allowed the differentiation of vaccinated from infected pigs. Serial studies were performed using sera collected from pigs in the field...... in Taiwan showed that the positive reactors steadily decreased over time in both finishers and sows, indicating that the pig population risk of infection by FMDV has decreased....

  1. Inaccuracy of Enzyme-Linked Immunosorbent Assay Using Soluble and Recombinant Antigens to Detect Asymptomatic Infection by Leishmania infantum

    Science.gov (United States)

    Moreno, Elizabeth Castro; Gonçalves, Andréa Vieira; Chaves, Anderson Vieira; Melo, Maria Norma; Lambertucci, José Roberto; Andrade, Antero Silva Ribeiro; Negrão-Corrêa, Deborah; Antunes, Carlos Mauricio de Figueiredo; Carneiro, Mariângela

    2009-01-01

    in population studies. Therefore, studies which have used serological assays to estimate prevalence, to evaluate intervention programs or to identify risk factors for Leishmania infection, may have had their results compromised. PMID:19841736

  2. Novel Electron Spin Resonance-Enzyme Immunosorbent Assay for Detecting Occult Hepatitis B Infection in HCV Chronic Liver Disease

    Directory of Open Access Journals (Sweden)

    Hala Badawi

    2017-11-01

    Full Text Available Background: Hepatitis B virus infection in patients who lack detectable hepatitis B surface antigen (HBsAg is called occult hepatitis B infection (OHB. The very low level of HBV genome may hamper its detection by molecular techniques. Recently, a highly sensitive EIA utilizing a novel modified electron spin resonance (ESR technique (modified ESR-EIA was developed to detect HBsAg by measuring stabilized nitroxide radicals. Aim: to detect occult HBV infection, using ESR-EIA among HCV-related chronic liver disease (CLD Egyptian patients who were seronegative for HBsAg by standard EIA. Methods: The study was conducted on two periods of time; in 1st period, 72 inpatients in Tropical Medicine Department of TBRI, were enrolled in the study. They were divided into two groups; 44 seropositive anti-HCV patients (Group I, 28 seronegative anti-HCV patients (Group II. Sera were subjected to virological assays for HBsAg, HBeAg, anti-HBc IgM, anti-HBc IgG, anti-HBs, anti-HCV and HCV RNA. We also examined serum HBV DNA by polymerase chain reaction (PCR technique and real-time detection polymerase chain reaction (RTD-PCR. In the 2nd period; modified ESR-EIA was applied on 32 TBRI inpatients, 23 in Tropical Medicine Department (Group I and 9 from hemodialysis unit (Group II with HCV-related CLD. Results: OHB was detected in 18.1% and 86.9% of our patients in 2002 and 2006 respectively. In phase 1, there was a higher detection rate among HCV patients in Group I (25% than Group II (7%, with higher prevalence (52.4% in patients with positive HCV RNA in Group I versus those with negative HCV viremia (8% in Group II. HBV DNA by either PCR or RTD-PCR was negative in all patients of both groups as the HBV viral load of the samples were below detectable level of the methods used; less than 100 copies/ml. None of 9 hemodialysis patients were positive for OHB. Conclusion: The newly developed quantitative ESR-EIA technique represents a great evolution for screening and

  3. Polymeric microbead arrays for microfluidic applications

    International Nuclear Information System (INIS)

    Thompson, Jason A; Du, Xiaoguang; Grogan, Joseph M; Schrlau, Michael G; Bau, Haim H

    2010-01-01

    Microbeads offer a convenient and efficient means of immobilizing biomolecules and capturing target molecules of interest in microfluidic immunoassay devices. In this study, hot embossing is used to form wells enabling the direct incorporation of a microbead array in a plastic substrate. We demonstrate two techniques to populate the well array with beads. In the first case, encoded beads with various functionalizations are distributed randomly among the wells and their position is registered by reading their encoding. Alternatively, beads are controllably placed at predetermined positions and decoding is not required. The random placement technique is demonstrated with two functionalized bead types that are distributed among the wells and then decoded to register their locations. The alternative, deliberate placement technique is demonstrated by controllably placing magnetic beads at selected locations in the array using a magnetic probe. As a proof of concept to illustrate the biosensing capability of the randomly assembled array, an on-chip, bead-based immunoassay is employed to detect the inflammatory protein Interleukin-8. The principle of the assay, however, can be extended to detect multiple targets simultaneously. Our method eliminates the need to interface silicon components with plastic devices to form microarrays containing individually addressable beads. This has the potential to reduce the cost and complexity of lab-on-chip devices for medical diagnosis, food and water quality inspection, and environmental monitoring

  4. Cross-reactivity of antibodies with phenolic compounds in pistachios during quantification of ochratoxin A by commercial enzyme-linked immunosorbent assay kits.

    Science.gov (United States)

    Lee, Hyun Jung; Meldrum, Alexander D; Rivera, Nicholas; Ryu, Dojin

    2014-10-01

    Ochratoxin A (OTA), a nephrotoxic mycotoxin, naturally occurs in wide range of agricultural commodities. Typical screening of OTA involves various enzyme-linked immunosorbent assay (ELISA) methods. Pistachio (Pistacia vera L.) is a rich source of phenolic compounds that may result in a false positive due to structural similarities to OTA. The present study investigated the cross-reactivity profiles of phenolic compounds using two commercial ELISA test kits. High-performance liquid chromatography was used to confirm the concentration of OTA in the pistachio samples and compared with the results obtained from ELISA. When the degree of interaction and 50 % inhibitory concentration of phenolic compounds were determined, the cross-reactivity showed a pattern similar to that observed with the commercial ELSIA kits, although quantitatively different. In addition, the degree of interaction increased with the increasing concentration of phenolic compounds. The ELISA value had stronger correlations with the content of total phenolic compound, gallic acid, and catechin (R(2) = 0.757, 0.732, and 0.729, respectively) compared with epicatechin (R(2) = 0.590). These results suggest that phenolic compounds in pistachio skins may cross-react with the OTA antibody and lead to a false positive or to an overestimation of OTA concentration in ELISA-based tests.

  5. Increased level of phosphorylated akt measured by chemiluminescence-linked immunosorbent assay is a predictor of poor prognosis in primary breast cancer overexpressing ErbB-2

    International Nuclear Information System (INIS)

    Cicenas, Jonas; Urban, Patrick; Vuaroqueaux, Vincent; Labuhn, Martin; Küng, Willy; Wight, Edward; Mayhew, Mark; Eppenberger, Urs; Eppenberger-Castori, Serenella

    2005-01-01

    Akt1, Akt2 and Akt3 kinases are downstream components of phosphoinositol 3-kinase derived signals from receptor tyrosine kinases, which influence cell growth, proliferation and survival. Akt2 overexpression and amplification have been described in breast, ovarian and pancreatic cancers. The present study was designed to investigate the prognostic significance of activated Akt in primary breast cancer and its association with other tumour biomarkers. Using a two-site chemiluminescence-linked immunosorbent assay, we measured the quantitative expression levels of total phosphorylated (P-S473) Akt (Akt1/Akt2/Akt3) on cytosol fractions obtained from fresh frozen tissue samples of 156 primary breast cancer patients. Akt phosphorylation was not associated with nodal status or ErbB-2 protein expression levels. High levels of phosphorylated Akt correlated (P < 0.01) with poor prognosis, and the significance of this correlation increased (P < 0.001) in the subset of patients with ErbB-2 overexpressing tumours. In addition, phosphorylated Akt was found to be associated with mRNA expression levels of several proliferation markers (e.g. thymidylate synthase), measured using quantitative real-time RT-PCR. Our findings demonstrate that, in breast cancer patients, Akt activation is associated with tumour proliferation and poor prognosis, particularly in the subset of patients with ErbB2-overexpressing tumours

  6. Commercial enzyme-linked immunosorbent assay versuspolymerase chain reaction for the diagnosis of chronic Chagas disease: a systematic review and meta-analysis

    Directory of Open Access Journals (Sweden)

    Pedro Emmanuel Alvarenga Americano do Brasil

    2016-01-01

    Full Text Available Chronic Chagas disease diagnosis relies on laboratory tests due to its clinical characteristics. The aim of this research was to review commercial enzyme-linked immunosorbent assay (ELISA and polymerase chain reaction (PCR diagnostic test performance. Performance of commercial ELISA or PCR for the diagnosis of chronic Chagas disease were systematically searched in PubMed, Scopus, Embase, ISI Web, and LILACS through the bibliography from 1980-2014 and by contact with the manufacturers. The risk of bias was assessed with QUADAS-2. Heterogeneity was estimated with the I2 statistic. Accuracies provided by the manufacturers usually overestimate the accuracy provided by academia. The risk of bias is high in most tests and in most QUADAS dimensions. Heterogeneity is high in either sensitivity, specificity, or both. The evidence regarding commercial ELISA and ELISA-rec sensitivity and specificity indicates that there is overestimation. The current recommendation to use two simultaneous serological tests can be supported by the risk of bias analysis and the amount of heterogeneity but not by the observed accuracies. The usefulness of PCR tests are debatable and health care providers should not order them on a routine basis. PCR may be used in selected cases due to its potential to detect seronegative subjects.

  7. Removal of Lipid from Serum Increases Coherence between Brucellosis Rapid Agglutination Test and Enzyme-linked Immunosorbent Assay in Bears in Alaska, USA.

    Science.gov (United States)

    Godfroid, Jacques; Beckmen, Kimberlee; Helena Nymo, Ingebjørg

    2016-10-01

    In cases of chronic Brucella spp. infection, results of the rose bengal plate test (RBPT) and indirect enzyme-linked immunosorbent assay (ELISA) should be coherent, as reported in controlled conditions in the literature. We compared RBPT and ELISA results in 58 Alaska grizzly bears ( Ursus arctos horribilis), eight Kodiak brown bears ( Ursus arctos middendorffi), and six Alaska Peninsula brown bears ( Ursus arctos gyas). Of the 72 bears tested, 42 (58%) were ELISA positive and 53 (73%) were RBPT positive. However, the coherence between the tests was only fair (K=0.37, SE=0.11), suggesting that either the serologic results were not compatible with Brucella spp. infection or that there was a technical problem with the tests. To address a potential technical problem, we performed a 30-min chloroform/centrifugation cleanup. Following cleanup, the ELISA identified 43 positives (59%) and the RBPT identified 47 (65%), and the coherence between the tests was much improved (K=0.80, SE=0.07). We recommend cleaning wildlife sera with a high lipid content before performing RBPT and performing RBPT and ELISA in parallel to assess coherence. Our results suggest that Alaskan brown bears have been exposed to Brucella spp.

  8. Enzyme-linked immunosorbent assay (ELISA) using a specific monoclonal antibody as a new tool to detect Sudan dyes and Para red

    International Nuclear Information System (INIS)

    Ju Chunmei; Tang Yong; Fan Huiying; Chen Jinding

    2008-01-01

    To set up an immunoassay-based method to detect Sudan dyes and Para red, we generated a monoclonal antibody (Mab) using a specially designed carboxyl derivative of Sudan I (CSD I) as the immunogen. CSD I was synthesized by azocoupling reaction using 2-naphthol and diazotised 4-aminobenzoic acid. The antibody was obtained from a hybridoma, which was derived from the fusion of the mouse myeloma SP2/0 cells and the splenocytes from the mice immunized with the CSD I-bovine serum albumin (BSA) conjugate. In addition, we showed that the Mab was highly specific for Sudan I, III and Para red. The limit of detection was approximately 0.01 ng mL -1 in phosphate-buffered saline (PBS) buffer and 0.5 ng g -1 in chilli tomato sauce. The recoveries of Sudan I, III and Para red for the chilli tomato sauce were from 84% to 99% and coefficients of variation were from 14.9% to 33.3%. Thus, the enzyme-linked immunosorbent assay (ELISA) method is a rapid and high throughput screening tool to detect Sudan dyes and Para red in food products

  9. Enzyme-linked immunosorbent assay (ELISA) using a specific monoclonal antibody as a new tool to detect Sudan dyes and Para red

    Energy Technology Data Exchange (ETDEWEB)

    Ju Chunmei [College of Veterinary Medicine, South China Agricultural University, Guangzhou 510642 (China); Tang Yong [Center of Antibody Engineering, Department of Bioengineering, Jinan University, Guangzhou 510632 (China); Fan Huiying [College of Veterinary Medicine, South China Agricultural University, Guangzhou 510642 (China); Chen Jinding [College of Veterinary Medicine, South China Agricultural University, Guangzhou 510642 (China)], E-mail: jdchen@scau.edu.cn

    2008-07-28

    To set up an immunoassay-based method to detect Sudan dyes and Para red, we generated a monoclonal antibody (Mab) using a specially designed carboxyl derivative of Sudan I (CSD I) as the immunogen. CSD I was synthesized by azocoupling reaction using 2-naphthol and diazotised 4-aminobenzoic acid. The antibody was obtained from a hybridoma, which was derived from the fusion of the mouse myeloma SP2/0 cells and the splenocytes from the mice immunized with the CSD I-bovine serum albumin (BSA) conjugate. In addition, we showed that the Mab was highly specific for Sudan I, III and Para red. The limit of detection was approximately 0.01 ng mL{sup -1} in phosphate-buffered saline (PBS) buffer and 0.5 ng g{sup -1} in chilli tomato sauce. The recoveries of Sudan I, III and Para red for the chilli tomato sauce were from 84% to 99% and coefficients of variation were from 14.9% to 33.3%. Thus, the enzyme-linked immunosorbent assay (ELISA) method is a rapid and high throughput screening tool to detect Sudan dyes and Para red in food products.

  10. Rapid Determination of Ractopamine Residues in Edible Animal Products by Enzyme-Linked Immunosorbent Assay: Development and Investigation of Matrix Effects

    Directory of Open Access Journals (Sweden)

    Yan Zhang

    2009-01-01

    Full Text Available To determine ractopamine residues in animal food products (chicken muscle, pettitoes, pig muscle, and pig liver, we established a rapid direct competitive enzyme-linked immunosorbent assay (ELISA using a polyclonal antibody generated from ractopamine-linker-BSA. The antibody showed high sensitivity and specificity in phosphate buffer, with an IC50 of 0.6 ng/mL, and the limit of detection was 0.04 ng/mL. The matrix effect of the samples was easily eliminated by one-step extraction with PBS, without any organic solution or clean-up procedure such as SPE or liquid-liquid extraction, making it a much more simple and rapid method than previously reported ones. The detection limit in blank samples was 0.2 μg/kg. To validate this new RAC (ractopamine hydrochloride ELISA, a RAC-free pig liver sample spiked at three different concentrations was prepared and analyzed by HPLC and ELISA. The results showed a good correlation between the data of ELISA and HPLC (R2>0.95, which proves that the established ELISA is accurate enough to quantify the residue of RAC in the animal derived foods.

  11. Establishment of the enzyme-linked immunosorbent assay system to detect the amino terminal secretory form of rat Erc/Mesothelin.

    Science.gov (United States)

    Nakaishi, Masayuki; Kajino, Kazunori; Ikesue, Masahiro; Hagiwara, Yoshiaki; Kuwahara, Maki; Mitani, Hiroaki; Horikoshi-Sakuraba, Yuko; Segawa, Tatsuya; Kon, Shigeyuki; Maeda, Masahiro; Wang, Tegexibaiyin; Abe, Masaaki; Yokoyama, Masayoshi; Hino, Okio

    2007-05-01

    By representational difference analysis, we previously identified the rat Erc (Expressed in renal carcinoma) gene that was more abundantly expressed in the renal carcinoma tissues of Eker rats than in the rat normal kidney. In this study, we raised antibodies against the amino-terminal portion of the rat Erc, and demonstrated the existence of a approximately 30-kDa secretory form in the supernatant of cultured cells derived from rat renal carcinoma. The enzyme-linked immunosorbent assay (ELISA) system using these antibodies detected high concentrations of this form in the sera of Eker rats bearing renal carcinomas, and in the sera of rats transplanted with mesothelioma cells. Mesothelin, a human homolog of the rat Erc, was recently reported to be a serum marker of malignant mesothelioma. The prognosis of mesothelioma is poor and there is no effective treatment at present. There are several rat model systems of mesothelioma that may be promising tools in the development of an antimesothelioma treatment. We hope our ELISA to detect the soluble form of rat Erc/Mesothelin is useful in the rat model system to exploit the antimesothelioma therapy to be used in human cases.

  12. Relative efficiency of polymerase chain reaction and enzyme-linked immunosorbant assay in determination of viral etiology in congenital cataract in infants

    Directory of Open Access Journals (Sweden)

    Shyamala G

    2008-01-01

    Full Text Available Background: Perinatal viral infections of fetus are among the leading causes of congenital cataract and identifying the viral etiology is important. Objectives: To detect the presence of Rubella virus (RV, herpes simplex virus (HSV and cytomegalovirus (CMV in lens aspirate specimens obtained from patients with congenital cataract and relate the results with serology. Setting and Design: Prospective study carried out in tertiary care hospital. Materials and Methods: Fifty lens aspirates from 50 infants with congenital cataract were subjected to HSV, RV isolation and polymerase chain reaction (PCR for detection of HSV and CMV. Reverse transcription polymerase chain reaction (RT-PCR was applied for RV detection. Peripheral blood specimens were screened for anti-HSV, RV and CMV antibodies by enzyme-linked immunosorbant assay (ELISA. Results: Rubella virus was detected in nine (18% lens aspirates, by nRT-PCR which includes six positive by culture. HSV-2 DNA was detected in nine other lens aspirates, while CMV was not detected by PCR. Serological results did not correlate with the presence of viruses in the lens aspirates. This is the first report of detection of HSV-2 DNA in cases of congenital cataract. Conclusions: Cytomegalovirus may not be playing a significant role in causation of congenital cataract. The role of serology in identifying causative viral infection for congenital cataract needs to be re-evaluated.

  13. Comparison of a neutralization enzyme immunoassay and an enzyme-linked immunosorbent assay for evaluation of immune status of children vaccinated for mumps.

    Science.gov (United States)

    Harmsen, T; Jongerius, M C; van der Zwan, C W; Plantinga, A D; Kraaijeveld, C A; Berbers, G A

    1992-01-01

    A 50% neutralization enzyme immunoassay (N50-EIA) was compared with an indirect enzyme-linked immunosorbent assay (ELISA) for determining mumps virus antibodies in three consecutive serum samples from 138 children vaccinated with a live mumps vaccine at the age (in years) of 1.5. By the N50-EIA, most (132 of 138) preserum samples did not show neutralizing activity. Eight to 12 weeks after vaccination, 17 of the children were still negative, but only 7 remained so after 2.5 years, resulting in a seroconversion rate of 125 of 132 (95%). Over the same period, the neutralization geometric mean titer rose from 3.6 to 9.9. By an indirect ELISA, 128 of 138 preserum samples were found negative. The early and late postvaccination sera of 8 children were ELISA negative, resulting in a seroconversion rate of 120 of 128 (94%). Only two children remained seronegative by both methods. Seven of the late postvaccination serum samples yielded noncorresponding results, reflecting 95% correlation between both methods. Due to cross-reactivity with parainfluenza viruses, the ELISA proved to be less specific, but on the other hand, it showed a greater sensitivity than the N50-EIA. PMID:1500523

  14. Comparison of Enzyme-Linked Immunosorbent Assay, Surface Plasmon Resonance and Biolayer Interferometry for Screening of Deoxynivalenol in Wheat and Wheat Dust

    Directory of Open Access Journals (Sweden)

    Melanie Sanders

    2016-04-01

    Full Text Available A sample preparation method was developed for the screening of deoxynivalenol (DON in wheat and wheat dust. Extraction was carried out with water and was successful due to the polar character of DON. For detection, an enzyme-linked immunosorbent assay (ELISA was compared to the sensor-based techniques of surface plasmon resonance (SPR and biolayer interferometry (BLI in terms of sensitivity, affinity and matrix effect. The matrix effects from wheat and wheat dust using SPR were too high to further use this screenings method. The preferred ELISA and BLI methods were validated according to the criteria established in Commission Regulation 519/2014/EC and Commission Decision 2002/657/EC. A small survey was executed on 16 wheat lots and their corresponding dust samples using the validated ELISA method. A linear correlation (r = 0.889 was found for the DON concentration in dust versus the DON concentration in wheat (LOD wheat: 233 μg/kg, LOD wheat dust: 458 μg/kg.

  15. Visual Detection of Canine Parvovirus Based on Loop-Mediated Isothermal Amplification Combined with Enzyme-Linked Immunosorbent Assay and with Lateral Flow Dipstick

    Science.gov (United States)

    SUN, Yu-Ling; YEN, Chon-Ho; TU, Ching-Fu

    2013-01-01

    ABSTRACT Loop-mediated isothermal amplification (LAMP) combined with enzyme-linked immunosorbent assay (LAMP–ELISA) and with lateral flow dipstick (LAMP–LFD) are rapid, sensitive and specific methods for the visual detection of clinical pathogens. In this study, LAMP–ELISA and LAMP–LFD were developed for the visual detection of canine parvovirus (CPV). For LAMP, a set of four primers (biotin-labeled forward inner primers) was designed to specifically amplify a region of the VP2 gene of CPV. The optimum time and temperature for LAMP were 60 min and 65°C, respectively. The specific capture oligonucleotide probes, biotin-labeled CPV probe for LAMP–ELISA and fluorescein isothiocyanate-labeled CPV probe for LAMP–LFD were also designed for hybridization with LAMP amplicons on streptavidin-coated wells and LFD strips, respectively. For the comparison of detection sensitivity, conventional PCR and LAMP for CPV detection were also performed. The CPV detection limits by PCR, PCR–ELISA, LAMP, LAMP–ELISA and LAMP–LFD were 102, 102, 10−1, 10−1 and 10−1 TCID50/ml, respectively. In tests using artificially contaminated dog fecal samples, the samples with CPV inoculation levels of ≥1 TCID50/ml gave positive results by both LAMP–ELISA and LAMP–LFD. Our data indicated that both LAMP–ELISA and LAMP–LFD are promising as rapid, sensitive and specific methods for an efficient diagnosis of CPV infection. PMID:24334855

  16. Discerning Silk Produced by Bombyx mori from Those Produced by Wild Species Using an Enzyme-Linked Immunosorbent Assay Combined with Conventional Methods.

    Science.gov (United States)

    You, Qiushi; Li, Qingqing; Zheng, Hailing; Hu, Zhiwen; Zhou, Yang; Wang, Bing

    2017-09-06

    Recently, much interest has been paid to the separation of silk produced by Bombyx mori from silk produced by other species and tracing the beginnings of silk cultivation from wild silk exploitation. In this paper, significant differences between silks from Bombyx mori and other species were found by microscopy and spectroscopy, such as morphology, secondary structure, and amino acid composition. For further accurate identification, a diagnostic antibody was designed by comparing the peptide sequences of silks produced by Bombyx mori and other species. The results of the noncompetitive indirect enzyme-linked immunosorbent assay (ELISA) indicated that the antibody that showed good sensitivity and high specificity can definitely discern silk produced by Bombyx mori from silk produced by wild species. Thus, the antibody-based immunoassay has the potential to be a powerful tool for tracing the beginnings of silk cultivation. In addition, combining the sensitive, specific, and convenient ELISA technology with other conventional methods can provide more in-depth and accurate information for species identification.

  17. Development of sandwich enzyme-linked immunosorbent assay systems for plasma β-galactoside α2,6-sialyltransferase, a possible hepatic disease biomarker

    International Nuclear Information System (INIS)

    Futakawa, Satoshi; Kitazume, Shinobu; Oka, Ritsuko; Ogawa, Kazuko; Hagiwara, Yoshiaki; Kinoshita, Akinori; Miyashita, Kazuya; Hashimoto, Yasuhiro

    2009-01-01

    Previous reports, including our work, have shown that plasma β-galactoside α2,6-sialyltransferase (ST6Gal I) activity is significantly increased in particular hepatopathological situations, suggesting that it may represent a sensitive biomarker for diagnosing hepatic diseases. So far, activity of ST6Gal I have been measured by using radioactive tracer method in place of measuring amount of ST6Gal I. However, this method is tangled and cannot exclude other sialyltransferase activities. Thus, simple and specific methods for measuring plasma ST6Gal I had been unavailable. Here, we developed two kinds of sandwich enzyme-linked immunosorbent assay (ELISA) systems that specifically detect the soluble cleaved form of ST6Gal I in plasma. In one sandwich ELISA, we detected rat specific sequence, EFQMPK, which is N-terminus of soluble ST6Gal I. In the other sandwich ELISA, we detected internal common sequence among rat, mouse and human ST6Gal I in plasma (M2 ELISA). Using the M2 ELISA, we observed that elevation of plasma ST6Gal I was much faster than elevation of plasma aspartate aminotransferase (AST) and alanine aminotransferase (ALT) in a carbon tetrachloride (CCl 4 )-induced mouse liver injury model. Our data suggest that these ELISA systems are very useful tools for measuring plasma ST6Gal I, which represents a potential biomarker for diagnosing hepatic diseases

  18. A Colorimetric Enzyme-Linked Immunosorbent Assay (ELISA) Detection Platform for a Point-of-Care Dengue Detection System on a Lab-on-Compact-Disc

    Science.gov (United States)

    Thiha, Aung; Ibrahim, Fatimah

    2015-01-01

    The enzyme-linked Immunosorbent Assay (ELISA) is the gold standard clinical diagnostic tool for the detection and quantification of protein biomarkers. However, conventional ELISA tests have drawbacks in their requirement of time, expensive equipment and expertise for operation. Hence, for the purpose of rapid, high throughput screening and point-of-care diagnosis, researchers are miniaturizing sandwich ELISA procedures on Lab-on-a-Chip and Lab-on-Compact Disc (LOCD) platforms. This paper presents a novel integrated device to detect and interpret the ELISA test results on a LOCD platform. The system applies absorption spectrophotometry to measure the absorbance (optical density) of the sample using a monochromatic light source and optical sensor. The device performs automated analysis of the results and presents absorbance values and diagnostic test results via a graphical display or via Bluetooth to a smartphone platform which also acts as controller of the device. The efficacy of the device was evaluated by performing dengue antibody IgG ELISA on 64 hospitalized patients suspected of dengue. The results demonstrate high accuracy of the device, with 95% sensitivity and 100% specificity in detection when compared with gold standard commercial ELISA microplate readers. This sensor platform represents a significant step towards establishing ELISA as a rapid, inexpensive and automatic testing method for the purpose of point-of-care-testing (POCT) in resource-limited settings. PMID:25993517

  19. Analysis of Benzo[a]pyrene in Vegetable Oils Using Molecularly Imprinted Solid Phase Extraction (MISPE Coupled with Enzyme-Linked Immunosorbent Assay (ELISA

    Directory of Open Access Journals (Sweden)

    Michael Pschenitza

    2014-05-01

    Full Text Available This paper describes the development of a molecularly imprinted polymer-based solid phase extraction (MISPE method coupled with enzyme-linked immunosorbent assay (ELISA for determination of the PAH benzo[a]pyrene (B[a]P in vegetable oils. Different molecularly imprinted polymers (MIPs were prepared using non-covalent 4-vinylpyridine/divinylbenzene co-polymerization at different ratios and dichloromethane as porogen. Imprinting was done with a template mixture of phenanthrene and pyrene yielding a broad-specific polymer for PAHs with a maximum binding capacity (Q of ~32 μg B[a]P per 50 mg of polymer. The vegetable oil/n-hexane mixture (1:1, (v/v was pre-extracted with acetonitrile, the solvent evaporated, the residue reconstituted in n-hexane and subjected to MISPE. The successive washing with n-hexane and isopropanol revealed most suitable to remove lipid matrix constituents. After elution of bound PAHs from MISPE column with dichloromethane, the solvent was evaporated, the residue reconstituted with dimethyl sulfoxide and diluted 100-fold with methanol/water (10:90, (v/v for analysis of B[a]P equivalents with an ELISA. The B[a]P recovery rates in spiked vegetable oil samples of different fatty acid composition were determined between 63% and 114%. The presence of multiple PAHs in the oil sample, because of MIP selectivity and cross-reactivity of the ELISA, could yield overestimated B[a]P values.

  20. Detection of Serum Thermolabile β-2 Macroglycoprotein (Hakata Antigen) by Enzyme-Linked Immunosorbent Assay Using Polysaccharide Produced by Aerococcus viridans

    Science.gov (United States)

    Tsujimura, Mitsushi; Ishida, Chuzo; Sagara, Yasuko; Miyazaki, Takashi; Murakami, Koichi; Shiraki, Hiroshi; Okochi, Kazuo; Maeda, Yoshiaki

    2001-01-01

    Although a serum thermolabile β-2 macroglycoprotein (TMG) may play a role in host defense as a lectin, little is known of its related physiological functions, mainly due to a lack of appropriate methods for tracing the functions of TMG. We identified a polysaccharide from Aerococcus viridans, PSA, which reacts with TMG, and based on this finding, we developed an enzyme-linked immunosorbent assay to trace the functions of TMG. Using ethanol precipitation and DEAE-Sepharose and Sephacryl S-400 column chromatographies, we isolated PSA from cultured medium of A. viridans, and it exhibited specific binding against TMG in blood samples. In sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE), the isolated PSA showed ladder bands that implied the existence of repeating units composed of d-glucose, N-acetyl-d-glucosamine, d-mannose, and d-xylose, as confirmed by gas chromatography-mass spectrometry. SDS-PAGE and immunochemical analysis, using rabbit anti-TMG antibody, showed that PSA specifically binds solely to intact serum TMG but not to TMG heated at 56°C for 30 min, a condition under which antigenicity is lost. TMG in serum samples bound to PSA in a dose-dependent manner, and this binding was clearly suppressed by addition of PSA. These observations indicate that PSA is a useful adsorbent to TMG and can be used to develop appropriate methods for tracing the functions of TMG. PMID:11238239

  1. Seroprevalence of Cryptosporidium parvum infection of dairy cows in three northern provinces of Thailand determined by enzyme-linked immunosorbent assay using recombinant antigen CpP23.

    Science.gov (United States)

    Inpankaew, T; Jittapalapong, S; Phasuk, J; Pinyopanuwut, N; Chimnoi, W; Kengradomkit, C; Sunanta, C; Zhang, G; Aboge, G O; Nishikawa, Y; Igarashi, I; Xuan, X

    2009-06-01

    Cryptosporidium parvum is the most frequent parasitic agent that causes diarrhoea in AIDS patients in Thailand. Cryptosporidiosis outbreaks in humans may be attributed to contamination of their drinking water from infected dairy pastures. A 23-kDa glycoprotein of C. parvum (CpP23) is a sporozoite surface protein that is geographically conserved among C. parvum isolates. This glycoprotein is a potentially useful candidate antigen for the diagnosis of cryptosporidiosis by enzyme-linked immunosorbent assay. Therefore, we investigated the seroprevalence of C. parvum infection in dairy cows in northern Thailand using an ELISA based on recombinant CpP23 antigen. Sera were randomly collected from 642 dairy cows of 42 small-holder farmers, which had the top three highest number of the dairy cows' population in Northern Thailand, that included Chiang Mai, Chiang Rai and Lumpang provinces. The overall seroprevalence of the infection was 4.4%, and the seropositive rates for the three provinces were 3.3% in Chiang Mai, 5.1% in Chiang Rai and 3% in Lumpang. These results suggest that cattle could play a role in zoonotic cryptosporidiosis in Thailand.

  2. Rapid determination of ractopamine residues in edible animal products by enzyme-linked immunosorbent assay: development and investigation of matrix effects.

    Science.gov (United States)

    Zhang, Yan; Wang, Fengxia; Fang, Li; Wang, Shuo; Fang, Guozhen

    2009-01-01

    To determine ractopamine residues in animal food products (chicken muscle, pettitoes, pig muscle, and pig liver), we established a rapid direct competitive enzyme-linked immunosorbent assay (ELISA) using a polyclonal antibody generated from ractopamine-linker-BSA. The antibody showed high sensitivity and specificity in phosphate buffer, with an IC(50) of 0.6 ng/mL, and the limit of detection was 0.04 ng/mL. The matrix effect of the samples was easily eliminated by one-step extraction with PBS, without any organic solution or clean-up procedure such as SPE or liquid-liquid extraction, making it a much more simple and rapid method than previously reported ones. The detection limit in blank samples was 0.2 mug/kg. To validate this new RAC (ractopamine hydrochloride) ELISA, a RAC-free pig liver sample spiked at three different concentrations was prepared and analyzed by HPLC and ELISA. The results showed a good correlation between the data of ELISA and HPLC (R(2) > 0.95), which proves that the established ELISA is accurate enough to quantify the residue of RAC in the animal derived foods.

  3. Evaluation of Enzyme-Linked Immunosorbent Assay for Diagnosis of Post-Kala-Azar Dermal Leishmaniasis with Crude or Recombinant k39 Antigen

    Science.gov (United States)

    Salotra, P.; Sreenivas, G.; Nasim, A. A.; Subba Raju, B. V.; Ramesh, V.

    2002-01-01

    The diagnosis of post-kala-azar dermal leishmaniasis (PKDL), a dermatosis that provides the only known reservoir for the parasite Leishmania donovani in India, remains a problem. Timely recognition and treatment of PKDL would contribute significantly to the control of kala-azar. We evaluated here the potential of the enzyme-linked immunosorbent assay (ELISA) as a diagnostic tool for PKDL. Antigen prepared from promastigotes and axenic amastigotes with parasite isolates that were derived from skin lesions of a PKDL patient gave sensitivities of 86.36 and 92%, respectively, in the 88 PKDL cases examined. The specificity of the ELISA test was examined by testing groups of patients with other skin disorders (leprosy and vitiligo) or coendemic infections (malaria and tuberculosis), as well as healthy controls from areas where this disease is endemic or is not endemic. A false-positive reaction was obtained in 14 of 144 (9.8%) of the controls with the promastigote antigen and in 14 of 145 (9.7%) of the controls with the amastigote antigen. Evaluation of the serodiagnostic potential of recombinant k39 by ELISA revealed a higher sensitivity (94.5%) and specificity (93.7%) compared to the other two antigens used. The data demonstrate that ELISA with crude or recombinant antigen k39 provides a relatively simple and less-invasive test for the reliable diagnosis of PKDL. PMID:11874880

  4. Development of a monoclonal antibody-based sandwich-type enzyme-linked immunosorbent assay (ELISA) for detection of abrin in food samples.

    Science.gov (United States)

    Zhou, Yu; Tian, Xiang-Li; Li, Yan-Song; Pan, Feng-Guang; Zhang, Yuan-Yuan; Zhang, Jun-Hui; Wang, Xin-Rui; Ren, Hong-Lin; Lu, Shi-Ying; Li, Zhao-Hui; Liu, Zeng-Shan; Chen, Qi-Jun; Liu, Jing-Qiu

    2012-12-15

    Abrin is a plant toxin, which can be easily isolated from the seeds of Abrus precatorius. It may be used as a biological warfare agent. In order to detect abrin in food samples, a two-layer sandwich format enzyme-linked immunosorbent assay based on the monoclonal antibody (mAb) (as capture antibody) and rabbit polyclonal serum (as detecting antibody) was developed and applied for the determination of abrin in some food matrices. The linear range of the mAb was 1-100 μg L(-1) with a detection limit of 0.5 μg L(-1) for abrin in phosphate buffered saline (PBS). The recoveries of abrin from sausage, beer and milk samples ranged 97.5-98.6%, 95.8-98.4% and 94.8-9.6%, respectively, with a coefficient of variation (CV) of 3.7% or less. The newly developed sandwich ELISA using the mAb appears to be a reliable and useful method for detection of abrin in sausage, beer and milk. Copyright © 2012 Elsevier Ltd. All rights reserved.

  5. Detection of Human Epididymis Protein 4 (HE4) in Human Serum Samples Using a Specific Monoclonal Antibody-Based Sandwich Enzyme-Linked Immunosorbent Assay (ELISA).

    Science.gov (United States)

    Zhou, Lijun; Lv, Zhiqiang; Shao, Jing; Xu, Ying; Luo, Xiaohong; Zhang, Yuming; Hu, Yang; Zhang, Wenji; Luo, Shuhong; Fang, Jianmin; Wang, Ying; Duan, Chaohui; Huang, Ruopan

    2016-09-01

    The human epididymis protein 4 (HE4) may have high specificity in the detection of malignant diseases, making the development of an immunoassay for HE4 essential. In our study, a fusion gene was constructed encoded with the HE4 protein. This protein was then produced in the bacterial cells (Escherichia coli) and used to immunize mice in order to eventually generate hybridomas specific to HE4. The hybridoma supernatants were then screened, and four positive anti-HE4 cell lines were selected. These cell lines produce monoclonal antibodies against HE4 epitopes, as demonstrated in the Western blot as well as by direct enzyme-linked immunosorbent assay (ELISA). Using the developed antibodies, we successfully identified several good antibody pairs from the hybridomas, which allowed for the development of a sandwich ELISA to measure HE4 levels. By using the HE4 ELISA, we measured HE4 levels of 60 clinical human serum samples. Compared with the Food and Drug Administration (FDA) approved kit (Roche), our results showed a strong positive correlation to those of the FDA-approved kit. In summary, highly sensitive antibody pairs were screened against HE4, and a sandwich ELISA was developed as an accurate analytical tool for the detection of HE4 in human serum, which could be especially valuable for diagnosing ovarian carcinomas. © 2015 Wiley Periodicals, Inc.

  6. Diagnostic accuracy of enzyme-linked immunosorbent assay (ELISA) and immunoblot (IB) for the detection of antibodies against Neospora caninum in milk from dairy cows.

    Science.gov (United States)

    Chatziprodromidou, I P; Apostolou, T

    2018-04-01

    The aim of the study was to estimate the sensitivity and specificity of enzyme-linked immunosorbent assay (ELISA) and immunoblot (IB) for detecting antibodies of Neospora caninum in dairy cows, in the absence of a gold standard. The study complies with STRADAS-paratuberculosis guidelines for reporting the accuracy of the test. We tried to apply Bayesian models that do not require conditional independence of the tests under evaluation, but as convergence problems appeared, we used Bayesian methodology, that does not assume conditional dependence of the tests. Informative prior probability distributions were constructed, based on scientific inputs regarding sensitivity and specificity of the IB test and the prevalence of disease in the studied populations. IB sensitivity and specificity were estimated to be 98.8% and 91.3%, respectively, while the respective estimates for ELISA were 60% and 96.7%. A sensitivity analysis, where modified prior probability distributions concerning IB diagnostic accuracy applied, showed a limited effect in posterior assessments. We concluded that ELISA can be used to screen the bulk milk and secondly, IB can be used whenever needed.

  7. Molecular detection of genotype II grass carp reovirus based on nucleic acid sequence-based amplification combined with enzyme-linked immunosorbent assay (NASBA-ELISA).

    Science.gov (United States)

    Zeng, Weiwei; Yao, Wei; Wang, Yingying; Li, Yingying; Bermann, Sven M; Ren, Yan; Shi, Cunbin; Song, Xinjian; Huang, Qiwen; Zheng, Shuchen; Wang, Qing

    2017-05-01

    Grass carp reovirus (GCRV) is the causative agent of the grass carp hemorrhagic disease that has resulted in severe economic losses in the grass carp (Ctenopharyngodon idella) farming industry in China. Early diagnosis and vaccine administration are important priorities for GCRV control. In this study, a nucleic acid sequence-based amplification with enzyme-linked immunosorbent assay (NASBA-ELISA) was developed for to detect genotype II GCRV (GCRV- II). Primers specifically targeting viral RNA genome segment 6 were utilized for amplification in an isothermal digoxigenin-labeling NASBA process, resulting in DIG-labeled RNA amplicons. The amplicons were hybridized to specific biotinylated DNA probes and the products were detected colorimetrically using horseradish peroxidase and a microplate reader. The new method is able to detect GCRV at 14 copies/μL within 5h and had a diagnostic sensitivity and a specificity of 100% when GCRV-II and non-target virus were tested. This NASBA-ELISA was evaluated using a panel of clinical samples (n=103) to demonstrate that it is a rapid, effective and sensitive method for GCRV detection in grass carp aquaculture. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Validation of the World Health Organization Enzyme-Linked Immunosorbent Assay for the Quantitation of Immunoglobulin G Serotype-Specific Anti-Pneumococcal Antibodies in Human Serum.

    Science.gov (United States)

    Lee, Hyunju; Lim, Soo Young; Kim, Kyung Hyo

    2017-10-01

    The World Health Organization (WHO) enzyme-linked immunosorbent assay (ELISA) guideline is currently accepted as the gold standard for the evaluation of immunoglobulin G (IgG) antibodies specific to pneumococcal capsular polysaccharide. We conducted validation of the WHO ELISA for 7 pneumococcal serotypes (4, 6B, 9V, 14, 18C, 19F, and 23F) by evaluating its specificity, precision (reproducibility and intermediate precision), accuracy, spiking recovery test, lower limit of quantification (LLOQ), and stability at the Ewha Center for Vaccine Evaluation and Study, Seoul, Korea. We found that the specificity, reproducibility, and intermediate precision were within acceptance ranges (reproducibility, coefficient of variability [CV] ≤ 15%; intermediate precision, CV ≤ 20%) for all serotypes. Comparisons between the provisional assignments of calibration sera and the results from this laboratory showed a high correlation > 94% for all 7 serotypes, supporting the accuracy of the ELISA. The spiking recovery test also fell within an acceptable range. The quantification limit, calculated using the LLOQ, for each of the serotypes was 0.05-0.093 μg/mL. The freeze-thaw stability and the short-term temperature stability were also within an acceptable range. In conclusion, we showed good performance using the standardized WHO ELISA for the evaluation of serotype-specific anti-pneumococcal IgG antibodies; the WHO ELISA can evaluate the immune response against pneumococcal vaccines with consistency and accuracy. © 2017 The Korean Academy of Medical Sciences.

  9. A Colorimetric Enzyme-Linked Immunosorbent Assay (ELISA) Detection Platform for a Point-of-Care Dengue Detection System on a Lab-on-Compact-Disc.

    Science.gov (United States)

    Thiha, Aung; Ibrahim, Fatimah

    2015-05-18

    The enzyme-linked Immunosorbent Assay (ELISA) is the gold standard clinical diagnostic tool for the detection and quantification of protein biomarkers. However, conventional ELISA tests have drawbacks in their requirement of time, expensive equipment and expertise for operation. Hence, for the purpose of rapid, high throughput screening and point-of-care diagnosis, researchers are miniaturizing sandwich ELISA procedures on Lab-on-a-Chip and Lab-on-Compact Disc (LOCD) platforms. This paper presents a novel integrated device to detect and interpret the ELISA test results on a LOCD platform. The system applies absorption spectrophotometry to measure the absorbance (optical density) of the sample using a monochromatic light source and optical sensor. The device performs automated analysis of the results and presents absorbance values and diagnostic test results via a graphical display or via Bluetooth to a smartphone platform which also acts as controller of the device. The efficacy of the device was evaluated by performing dengue antibody IgG ELISA on 64 hospitalized patients suspected of dengue. The results demonstrate high accuracy of the device, with 95% sensitivity and 100% specificity in detection when compared with gold standard commercial ELISA microplate readers. This sensor platform represents a significant step towards establishing ELISA as a rapid, inexpensive and automatic testing method for the purpose of point-of-care-testing (POCT) in resource-limited settings.

  10. Increased sensitivity of 3D-Well enzyme-linked immunosorbent assay (ELISA) for infectious disease detection using 3D-printing fabrication technology.

    Science.gov (United States)

    Singh, Harpal; Shimojima, Masayuki; Fukushi, Shuetsu; Le Van, An; Sugamata, Masami; Yang, Ming

    2015-01-01

    Enzyme-linked Immunosorbent Assay or ELISA -based diagnostics are considered the gold standard in the demonstration of various immunological reaction including in the measurement of antibody response to infectious diseases and to support pathogen identification with application potential in infectious disease outbreaks and individual patients' treatment and clinical care. The rapid prototyping of ELISA-based diagnostics using available 3D printing technologies provides an opportunity for a further exploration of this platform into immunodetection systems. In this study, a '3D-Well' was designed and fabricated using available 3D printing platforms to have an increased surface area of more than 4 times for protein-surface adsorption compared to those of 96-well plates. The ease and rapidity in designing-product development-feedback cycle offered through 3D printing platforms provided an opportunity for its rapid assessment, in which a chemical etching process was used to make the surface hydrophilic followed by validation through the diagnostic performance of ELISA for infectious disease without modifying current laboratory practices for ELISA. The higher sensitivity of the 3D-Well (3-folds higher) compared to the 96-well ELISA provides a potential for the expansion of this technology towards miniaturization platforms to reduce time, volume of reagents and samples needed for laboratory or field diagnosis of infectious diseases including applications in other disciplines.

  11. Development of sandwich enzyme-linked immunosorbent assay systems for plasma {beta}-galactoside {alpha}2,6-sialyltransferase, a possible hepatic disease biomarker

    Energy Technology Data Exchange (ETDEWEB)

    Futakawa, Satoshi [Department of Biochemistry, School of Medicine, Fukushima Medical University, 1 Hikarigaoka, Fukushima-shi, Fukushima 960-1295 (Japan); Kitazume, Shinobu [Disease Glycomics Laboratory, Institute of Physical and Chemical Research, RIKEN, 2-1 Hirosawa, Wako-shi, Saitama 351-0198 (Japan); CREST, Japan Science and Technology Agency, Kawaguchi-shi, Saitama 560-0082 (Japan); Oka, Ritsuko [CREST, Japan Science and Technology Agency, Kawaguchi-shi, Saitama 560-0082 (Japan); Glyco-chain Functions Laboratory, Institute of Physical and Chemical Research, RIKEN, 2-1 Hirosawa, Wako-shi, Saitama 351-0198 (Japan); Ogawa, Kazuko [Disease Glycomics Laboratory, Institute of Physical and Chemical Research, RIKEN, 2-1 Hirosawa, Wako-shi, Saitama 351-0198 (Japan); CREST, Japan Science and Technology Agency, Kawaguchi-shi, Saitama 560-0082 (Japan); Hagiwara, Yoshiaki; Kinoshita, Akinori; Miyashita, Kazuya [Department of Biological Sciences, Immuno-Biological Laboratories Co. Ltd., 1091-1 Naka, Fujioka-shi, Gunma 375-0005 (Japan); Hashimoto, Yasuhiro [Department of Biochemistry, School of Medicine, Fukushima Medical University, 1 Hikarigaoka, Fukushima-shi, Fukushima 960-1295 (Japan); CREST, Japan Science and Technology Agency, Kawaguchi-shi, Saitama 560-0082 (Japan)], E-mail: yasuc@fmu.ac.jp

    2009-01-05

    Previous reports, including our work, have shown that plasma {beta}-galactoside {alpha}2,6-sialyltransferase (ST6Gal I) activity is significantly increased in particular hepatopathological situations, suggesting that it may represent a sensitive biomarker for diagnosing hepatic diseases. So far, activity of ST6Gal I have been measured by using radioactive tracer method in place of measuring amount of ST6Gal I. However, this method is tangled and cannot exclude other sialyltransferase activities. Thus, simple and specific methods for measuring plasma ST6Gal I had been unavailable. Here, we developed two kinds of sandwich enzyme-linked immunosorbent assay (ELISA) systems that specifically detect the soluble cleaved form of ST6Gal I in plasma. In one sandwich ELISA, we detected rat specific sequence, EFQMPK, which is N-terminus of soluble ST6Gal I. In the other sandwich ELISA, we detected internal common sequence among rat, mouse and human ST6Gal I in plasma (M2 ELISA). Using the M2 ELISA, we observed that elevation of plasma ST6Gal I was much faster than elevation of plasma aspartate aminotransferase (AST) and alanine aminotransferase (ALT) in a carbon tetrachloride (CCl{sub 4})-induced mouse liver injury model. Our data suggest that these ELISA systems are very useful tools for measuring plasma ST6Gal I, which represents a potential biomarker for diagnosing hepatic diseases.

  12. Parvovirus B19 infections in state of Rio de Janeiro, Brasil: 526 sera analyzed by IgM-enzyme-linked immunosorbent assay and polymerase chain reaction

    Directory of Open Access Journals (Sweden)

    MCL Mendonça

    2005-12-01

    Full Text Available In this study were analyzed 526 sera; the patients aged from two days to 65 years old presenting exanthema, which was the most frequent symptom observed, besides fever, adenomegaly, and arthralgia. These sera were negative by enzyme-linked immunosorbent assay (IgM-ELISA for either rubella (495, toxoplasma (41, cytomegalovirus (12, measles (40, dengue (56, and they were submitted to nested polymerase chain reaction (PCR for B19 DNA and commercial IgM-ELISA for B19. In 39 abortion cases, IgM or DNA were not detected, therefore they were not took into account for analysis. Specific DNA and IgM were detected respectively in 71 (14.5% and IgM in 62 (12.7% sera from 487 sera analyzed. IgM and DNA were simultaneously detected in 43 (8.8%, while agreement among the results by PCR and IgM-ELISA was observed in 440 (90.4%. The sera were collected from January 1999 to December 2000, most of them in 1999 (325, during winter and spring. The major number of clinical cases was observed in the age group from one to ten years old. IgM or DNA were detected in 23 from 51 municipal districts of the state of Rio de Janeiro, where the samples were collected.

  13. Development of a Nucleoprotein-Based Enzyme-Linked Immunosorbent Assay Using a Synthetic Peptide Antigen for Detection of Avian Metapneumovirus Antibodies in Turkey Sera

    Science.gov (United States)

    Alvarez, Rene; Njenga, M. Kariuki; Scott, Melissa; Seal, Bruce S.

    2004-01-01

    Avian metapneumoviruses (aMPV) cause an upper respiratory tract disease with low mortality but high morbidity, primarily in commercial turkeys, that can be exacerbated by secondary infections. There are three types of aMPV, of which type C is found only in the United States. The aMPV nucleoprotein (N) amino acid sequences of serotypes A, B, and C were aligned for comparative analysis. On the basis of the predicted antigenicity of consensus sequences, five aMPV-specific N peptides were synthesized for development of a peptide antigen enzyme-linked immunosorbent assay (aMPV N peptide-based ELISA) to detect aMPV-specific antibodies among turkeys. Sera from naturally and experimentally infected turkeys were used to demonstrate the presence of antibodies reactive to the chemically synthesized aMPV N peptides. Subsequently, aMPV N peptide 1, which had the sequence 10-DLSYKHAILKESQYTIKRDV-29, with variations at only three amino acids among aMPV serotypes, was evaluated as a universal aMPV ELISA antigen. Data obtained with the peptide-based ELISA correlated positively with total aMPV viral antigen-based ELISAs, and the peptide ELISA provided higher optical density readings. The results indicated that aMPV N peptide 1 can be used as a universal ELISA antigen to detect antibodies for all aMPV serotypes. PMID:15013970

  14. Field estimation of the flock-level diagnostic specificity of an enzyme-linked immunosorbent assay for Avian metapneumovirus antibodies in turkeys.

    Science.gov (United States)

    Muñoz-Zanzi, Claudia; Trampel, Darrell; Hanson, Tim; Harrison, Kristen; Goyal, Sagar; Cortinas, Roberto; Lauer, Dale

    2009-03-01

    Routine serologic testing for Avian metapneumovirus (AMPV) infection of turkey flocks at slaughter is currently being used to monitor changes in the occurrence of AMPV infection in endemic areas and can also be used to detect the emergence of infection in currently unaffected areas. Because of the costs associated with false-positive results, particularly in areas that are free of AMPV infection, there is a need to obtain improved estimates of flock-level specificity (SP). The objective of this study was to estimate flock-level SP of a program to monitor AMPV infection in turkey flocks at processing using a standard enzyme-linked immunosorbent assay (ELISA). A study was carried out in which 37 AMPV-free flocks from 7 Midwest operations were followed serologically. Six percent, 3%, and 0.2% of total samples tested AMPV positive at 8 weeks, 12 weeks, and at processing, respectively. Overall, flock-level SP increased as the cutoff increased and as age increased. Flock-level SP at processing was 97%, if a cutoff of 1 was used (the flock was classified as positive if at least 1 sample tested positive), and 100%, if any other cutoff was used. Administration of antibiotics (P = 0.02) and vaccination for Bordetella avium (P = 0.08) were positively associated with the probability of (false) positive test results. These findings suggest possible cross-reactions with other infections and highlight the need to consider variable diagnostic performance depending on farm conditions.

  15. Comparison of the membrane-filtration fluorescent antibody test, the enzyme-linked immunosorbent assay, and the polymerase chain reaction to detect Renibacterium salmoninarum in salmon ovarian fluid

    Science.gov (United States)

    Pascho, Ronald J.; Chase, Dorothy M.; McKibben, Constance L.

    1998-01-01

    Ovarian fluid samples from naturally infected chinook salmon (Oncorhynchus tshawytscha) were examined for the presence of Renibacterium salmoninarum by the membrane-filtration fluorescent antibody test (MF-FAT), an antigen capture enzyme-linked immunosorbent assay (ELISA), and a nested polymerase chain reaction (PCR). On the basis of the MF-FAT, 64% (66/103) samples contained detectable levels of R. salmoninarum cells. Among the positive fish, the R. salmoninarum concentrations ranged from 25 cells/ml to 4.3 × 109cells/ml. A soluble antigenic fraction of R. salmoninarum was detected in 39% of the fish (40/103) by the ELISA. The ELISA is considered one of the most sensitive detection methods for bacterial kidney disease in tissues, yet it did not detect R. salmoninarum antigen consistently at bacterial cell concentrations below about 1.3 × 104cells/ml according to the MF-FAT counts. When total DNA was extracted and tested in a nested PCR designed to amplify a 320-base-pair region of the gene encoding a soluble 57-kD protein of R. salmoninarum, 100% of the 100 samples tested were positive. The results provided strong evidence that R. salmoninarum may be present in ovarian fluids thought to be free of the bacterium on the basis of standard diagnostic methods.

  16. Enzyme-Linked Immunosorbent Assay Using a Virus Type-Specific Peptide Based on a Subdomain of Envelope Protein Erns for Serologic Diagnosis of Pestivirus Infections in Swine

    Science.gov (United States)

    Langedijk, J. P. M.; Middel, W. G. J.; Meloen, R. H.; Kramps, J. A.; de Smit, J. A.

    2001-01-01

    Peptides deduced from the C-terminal end (residues 191 to 227) of pestivirus envelope protein Erns were used to develop enzyme-linked immunosorbent assays (ELISAs) to measure specifically antibodies against different types of pestiviruses. The choice of the peptide was based on the modular structure of the Erns protein, and the peptide was selected for its probable independent folding and good exposure, which would make it a good candidate for an antigenic peptide to be used in a diagnostic test. A solid-phase peptide ELISA which was cross-reactive for several types of pestivirus antibodies and which can be used for the general detection of pestivirus antibodies was developed. To identify type-specific pestivirus antibodies, a liquid-phase peptide ELISA, with a labeled, specific classical swine fever virus (CSFV) peptide and an unlabeled bovine viral diarrhea virus peptide to block cross-reactivity, was developed. Specificity and sensitivity of the liquid-phase peptide ELISA for CSFV were 98 and 100%, respectively. Because the peptide is a fragment of the Erns protein, it can be used to differentiate between infected and vaccinated animals when a vaccine based on the E2 protein, which is another pestivirus envelope protein, is used. PMID:11230402

  17. Evaluation of a newly designed sandwich enzyme linked immunosorbent assay for the detection of hydatid antigen in serum, urine and cyst fluid for diagnosis of cystic echinococcosis.

    Science.gov (United States)

    Chaya, Dr; Parija, Subhash Chandra

    2013-07-01

    Cystic echinococcosis (CE) is a zoonotic disease of humans with variable clinical manifestations. Imaging and immunological methods are currently the mainstay of diagnosis of this disease. Although the immunological tests for detection of anti-echinococcal antibodies have several disadvantages, they are widely being used. Antigen is far more superior than antibody detection test as they can provide a specific parasitic diagnosis. A sandwich enzyme linked immunosorbent assay (ELISA) was designed using antibodies to 24 kDa urinary hydatid antigen for the detection of hydatid antigens in urine, serum and cyst fluid specimens. The performance of this novel test was compared with that of other hydatid antibody detection ELISA and enzyme immune transfer blot (EITB) using radiological and surgical confirmation as the gold standard. The antigen detection ELISA showed 100% sensitivity and specificity when tested with cyst fluid. On testing urine and serum, the antigen detection ELISA was found to be more specific than antibody detection ELISA. EITB was found to be the most sensitive and specific test. ELISA using polyclonal antibodies against 24 kDa urinary hydatid protein was moderately sensitive to detect hydatid antigen in serum and urine. Hence polyclonal antibodies to 24 kDa urinary hydatid antigen can be used as an alternative source of antibody to detect hydatid antigen in serum, urine and cyst fluid. In the present study, EITB was found to be highly specific test for detection of hydatid antibodiesin serum. 24 kDa protein was found to be specific and of diagnostic value in CE.

  18. Enzyme-linked immunosorbent assay and polymerase chain reaction performance using Mexican and Guatemalan discrete typing unit I strains of Trypanosoma cruzi.

    Science.gov (United States)

    Ballinas-Verdugo, Martha; Reyes, Pedro Antonio; Mejia-Dominguez, Ana; López, Ruth; Matta, Vivian; Monteón, Victor M

    2011-12-01

    Thirteen Trypanosoma cruzi isolates from different geographic regions of Mexico and Guatemala belonging to discrete typing unit (DTU) I and a reference CL-Brener (DTU VI) strain were used to perform enzyme-linked immunosorbent assay (ELISA) and polymerase chain reaction (PCR). A panel of 57 Mexican serum samples of patients with chronic chagasic cardiopathy and asymptomatic infected subjects (blood bank donors) were used in this study. DNA from the above 14 T. cruzi strains were extracted and analyzed by PCR using different sets of primers designed from minicircle and satellite T. cruzi DNA. The chronic chagasic cardiopathy serum samples were easily recognized with ELISA regardless of the source of antigenic extract used, even with the CL-Brener TcVI, but positive serum samples from blood bank donors in some cases were not recognized by some Mexican antigenic extracts. On the other hand, PCR showed an excellent performance despite the set of primers used, since all Mexican and Guatemalan T. cruzi strains were correctly amplified. In general terms, Mexican, Guatemalan, and CL-Brener T. cruzi strains are equally good sources of antigen when using the ELISA test to detect Mexican serum samples. However, there are some strains with poor performance. The DTU I strains are easily detected using either kinetoplast or satellite DNA target designed from DTU VI strains.

  19. Diagnostic accuracy of the anti-glutamic acid decarboxylase antibody in type 1 diabetes mellitus: Comparison between radioimmunoassay and enzyme-linked immunosorbent assay.

    Science.gov (United States)

    Murata, Takashi; Tsuzaki, Kokoro; Nirengi, Shinsuke; Watanabe, Tomokazu; Mizutani, Yukako; Okada, Hayami; Tsukamoto, Masami; Odori, Shinji; Nakagawachi, Reiko; Kawaguchi, Yaeko; Yoshioka, Fumi; Yamada, Kazunori; Shimatsu, Akira; Kotani, Kazuhiko; Satoh-Asahara, Noriko; Sakane, Naoki

    2017-07-01

    The distributer of the anti-glutamic acid decarboxylase antibody assay kit using radioimmunoassay (RIA) recently announced its discontinuation, and proposed an alternative kit using enzyme-linked immunosorbent assay (ELISA). The aim of the present study was to investigate the diagnostic values of the anti-glutamic acid decarboxylase antibody by RIA and ELISA among type 1 diabetes mellitus patients and control participants. A total of 79 type 1 diabetes mellitus patients and 79 age-matched controls were enrolled and assessed using RIA and ELISA. Sensitivity, specificity, positive predictive values and negative predictive values were calculated for cut-off values (RIA = 1.5 U/mL and ELISA = 5.0 U/mL, respectively). Kappa coefficients were used to test for agreements between the RIA and ELISA methods regarding the diagnosis of type 1 diabetes mellitus. The sensitivity, specificity, positive predictive values, and negative predictive values for diagnosing type 1 diabetes mellitus were 57.0, 97.5, 95.7, and 69.4% by RIA, and 60.8, 100.0, 100.0 and 71.8% by ELISA, respectively. The diagnosis of type 1 diabetes mellitus using the RIA and ELISA methods showed substantial agreement with the kappa values of 0.74 for all participants, and of 0.64 for the acute type; however, there was moderate agreement with the kappa value of 0.56 for the slowly progressive type. The present study suggests that both anti-glutamic acid decarboxylase antibody by RIA and ELISA was useful for diagnosing type 1 diabetes mellitus. However, in the slowly progressive type, the degree of agreement of these two kits was poorer compared with those in all participants or in the acute type. © 2016 The Authors. Journal of Diabetes Investigation published by Asian Association for the Study of Diabetes (AASD) and John Wiley & Sons Australia, Ltd.

  20. A novel whole-bacterial enzyme linked-immunosorbant assay to quantify Chlamydia trachomatis specific antibodies reveals distinct differences between systemic and genital compartments.

    Directory of Open Access Journals (Sweden)

    Hannah L Albritton

    Full Text Available Chlamydia trachomatis (CT is the leading sexually transmitted bacterial infection. The continued global burden of CT infection strongly predicates the need for a vaccine to supplement current chlamydial control programs. The correlates of protection against CT are currently unknown, but they must be carefully defined to guide vaccine design. The localized nature of chlamydial infection in columnar epithelial cells of the genital tract necessitates investigation of immunity at the site of infection. The purpose of this study was to develop a sensitive whole bacterial enzyme-linked immunosorbent assay (ELISA to quantify and compare CT-specific IgG and IgA in sera and genital secretions from CT-infected women. To achieve this, elementary bodies (EBs from two of the most common genital serovars (D and E were attached to poly-L-lysine-coated microtiter plates with glutaraldehyde. EB attachment and integrity were verified by the presence of outer membrane antigens and the absence of bacterial cytoplasmic antigens. EB-specific IgG and IgA standards were developed by pooling sera with high titers of CT-specific antibodies from infected women. Serum, endocervical and vaginal secretions, and endocervical cytobrush specimens from CT-infected women were used to quantify CT-specific IgG and IgA which were then normalized to total IgG and IgA, respectively. Analyses of paired serum and genital samples revealed significantly higher proportions of EB-specific antibodies in genital secretions compared to sera. Cervical and vaginal secretions and cytobrush specimens had similar proportions of EB-specific antibodies, suggesting any one of these genital sampling techniques could be used to quantify CT-specific antibodies when appropriate normalization methodologies are implemented. Overall, these results illustrate the need to investigate genital tract CT antibody responses, and our assay provides a useful quantitative tool to assess natural immunity in defined

  1. Diagnostic efficacy of monoclonal antibody based sandwich enzyme linked immunosorbent assay (ELISA for detection of Fasciola gigantica excretory/secretory antigens in both serum and stool

    Directory of Open Access Journals (Sweden)

    Zoheiry Mona K

    2011-09-01

    Full Text Available Abstract Background This research was carried out to develop a reliable monoclonal antibody (MoAb-based sandwich enzyme linked immunosorbent assay (ELISA for the diagnosis of active Fasciola gigantica infection in both serum and stool for comparative purposes. Methods From a panel of MoAbs raised against F. gigantica excretory/secretory antigens (ES Ags, a pair (12B/11D/3F and 10A/9D/10G was chosen due to its high reactivity and strict specificity to F. gigantica antigen by indirect ELISA. Results The two MoAbs were of the IgG1 and IgG2a subclasses, respectively. Using SDS-PAGE and EITB, the selected MoAbs recognized 83, 64, 45 and 26 kDa bands of ES Ags. The lower detection limit of ELISA assay was 3 ng/ml. In stool, the sensitivity, specificity and diagnostic efficacy of ELISA was 96%, 98.2 and 97.1%; while in serum they were 94%, 94.6% and 94.3%, respectively. Moreover, a positive correlation was found between ova count in stool of F. gigantica infected patients and the OD readings of ELISA in both stool and serum samples (r = 0.730, p Conclusions These data showed that the use of MoAb-based sandwich ELISA for the detection of F. gigantica coproantigens in stool specimens was superior to serum samples; it provides a highly efficient, non-invasive technique for the diagnosis of active F. gigantica infection.

  2. Development of an indirect competitive enzyme-linked immunosorbent assay applied to the Botrytis cinerea quantification in tissues of postharvest fruits

    Directory of Open Access Journals (Sweden)

    Raba Julio

    2011-10-01

    Full Text Available Abstract Background Botrytis cinerea is a phytopathogenic fungus responsible for the disease known as gray mold, which causes substantial losses of fruits at postharvest. This fungus is present often as latent infection and an apparently healthy fruit can deteriorate suddenly due to the development of this infection. For this reason, rapid and sensitive methods are necessary for its detection and quantification. This article describes the development of an indirect competitive enzyme-linked immunosorbent assay (ELISA for quantification of B. cinerea in apple (Red Delicious, table grape (pink Moscatel, and pear (William's tissues. Results The method was based in the competition for the binding site of monoclonal antibodies between B. cinerea antigens present in fruit tissues and B. cinerea purified antigens immobilized by a crosslinking agent onto the surface of the microtiter plates. The method was validated considering parameters such as selectivity, linearity, precision, accuracy and sensibility. The calculated detection limit was 0.97 μg mL-1 B. cinerea antigens. The immobilized antigen was perfectly stable for at least 4 months assuring the reproducibility of the assay. The fungus was detected and quantified in any of the fruits tested when the rot was not visible yet. Results were compared with a DNA quantification method and these studies showed good correlation. Conclusions The developed method allowed detects the presence of B. cinerea in asymptomatic fruits and provides the advantages of low cost, easy operation, and short analysis time determination for its possible application in the phytosanitary programs of the fruit industry worldwide.

  3. Development of an enzyme-linked immunosorbent assay (ELISA)-like fluorescence assay to investigate the interactions of glycosaminoglycans to cells

    Energy Technology Data Exchange (ETDEWEB)

    Boucas, Rodrigo Ippolito [Disciplina de Biologia Molecular, Departamento de Bioquimica, Universidade Federal de Sao Paulo, SP (Brazil); Trindade, Edvaldo S. [Disciplina de Biologia Molecular, Departamento de Bioquimica, Universidade Federal de Sao Paulo, SP (Brazil); Departamento de Biologia Celular, Universidade Federal do Parana, Curitiba, Parana (Brazil); Tersariol, Ivarne L.S. [Disciplina de Biologia Molecular, Departamento de Bioquimica, Universidade Federal de Sao Paulo, SP (Brazil); Centro Interdisciplinar de Investigacao Bioquimica, Universidade de Mogi das Cruzes, Mogi das Cruzes, SP (Brazil); Dietrich, Carl P. [Disciplina de Biologia Molecular, Departamento de Bioquimica, Universidade Federal de Sao Paulo, SP (Brazil); Nader, Helena B. [Disciplina de Biologia Molecular, Departamento de Bioquimica, Universidade Federal de Sao Paulo, SP (Brazil)], E-mail: hbnader.bioq@epm.br

    2008-06-23

    Sulfated glycosaminoglycans were labeled with biotin to study their interaction with cells in culture. Thus, heparin, heparan sulfate, chondroitin 4-sulfate, chondroitin 6-sulfate and dermatan sulfate were labeled using biotin-hydrazide, under different conditions. The structural characteristics of the biotinylated products were determined by chemical (molar ratios of hexosamine, uronic acid, sulfate and biotin) and enzymatic methods (susceptibility to degradation by chondroitinases and heparitinases). The binding of biotinylated glycosaminoglycans was investigated both in endothelial and smooth muscle cells in culture, using a novel time resolved fluorometric method based on interaction of europium-labeled streptavidin with the biotin covalently linked to the compounds. The interactions of glycosaminoglycans were saturable and number of binding sites could be obtained for each individual compound. The apparent dissociation constant varied among the different glycosaminoglycans and between the two cell lines. The interactions of the biotinylated glycosaminoglycans with the cells were also evaluated using confocal microscopy. We propose a convenient and reliable method for the preparation of biotinylated glycosaminoglycans, as well as a sensitive non-competitive fluorescence-based assay for studies of the interactions and binding of these compounds to cells in culture.

  4. Development of an enzyme-linked immunosorbent assay (ELISA)-like fluorescence assay to investigate the interactions of glycosaminoglycans to cells

    International Nuclear Information System (INIS)

    Boucas, Rodrigo Ippolito; Trindade, Edvaldo S.; Tersariol, Ivarne L.S.; Dietrich, Carl P.; Nader, Helena B.

    2008-01-01

    Sulfated glycosaminoglycans were labeled with biotin to study their interaction with cells in culture. Thus, heparin, heparan sulfate, chondroitin 4-sulfate, chondroitin 6-sulfate and dermatan sulfate were labeled using biotin-hydrazide, under different conditions. The structural characteristics of the biotinylated products were determined by chemical (molar ratios of hexosamine, uronic acid, sulfate and biotin) and enzymatic methods (susceptibility to degradation by chondroitinases and heparitinases). The binding of biotinylated glycosaminoglycans was investigated both in endothelial and smooth muscle cells in culture, using a novel time resolved fluorometric method based on interaction of europium-labeled streptavidin with the biotin covalently linked to the compounds. The interactions of glycosaminoglycans were saturable and number of binding sites could be obtained for each individual compound. The apparent dissociation constant varied among the different glycosaminoglycans and between the two cell lines. The interactions of the biotinylated glycosaminoglycans with the cells were also evaluated using confocal microscopy. We propose a convenient and reliable method for the preparation of biotinylated glycosaminoglycans, as well as a sensitive non-competitive fluorescence-based assay for studies of the interactions and binding of these compounds to cells in culture

  5. Standardization of micro-enzyme-linked immunosorbent assay (ELISA) and Western blot for detection of Trypanosoma cruzi antibodies using extracts from Mexican strains as antigens.

    Science.gov (United States)

    Sánchez, B; Monteón, V; Reyes, P A; Espinoza, B

    2001-01-01

    This report describes two assays for the detection of anti-Trypanosoma cruzi antibodies using Mexican strains of the parasite and the concordance with two assays previously evaluated at the Instituto Nacional de Cardiología Ignacio Chávez in Mexico City. Micro-enzyme-linked immunosorbent assay (ELISA) and Western blot were used for the detection of T. cruzi antibodies with a total extract of epimastigote from Ninoa and Queretaro, which are Mexican strains of T. cruzi. To standardize these methods, a total of 246 serum samples was used. In addition, sera from six confirmed Mexican chronic individuals in the asymptomatic phase were also used for comparison with the Argentinean antigen. ELISA was 100% specific in that no false positive results were found with sera of both healthy individuals and non-Chagasic cardiopaths. Sera from individuals infected with Leishmania sp. showed approximately 16% of cross-reaction with ELISA. The test showed a positive predictive value of 90% and a negative predictive value of 100%. Western blot was also a highly sensitive test for detecting chronic Chagasic symptomatic patients from Mexico because no false negative results were obtained. Furthermore, it was possible to use Western blot to detect seven immunodominant antigens of approximately 30, 32, 40, 42, 65, 70, and 83 kDa. Concordance with two previous standardized tests at the Instituto Nacional de Cardiología showed a Kappa index of 0.96, indicating high concordance between the results obtained at these two laboratories. Finally, ELISA using Ninoa antigen extract was more sensitive than ELISA with an Argentinean extract, which failed to detect individuals in the chronic asymptomatic phase (undetermined phase) of infection. This study indicates that ELISA and Western blot using Ninoa and/or Queretaro extracts of T. cruzi as antigens are useful tools in the detection of individuals who have been exposed to T. cruzi both in the undetermined/asymptomatic and symptomatic phases

  6. Enzyme-linked immunosorbent assay gliadin assessment in processed food products available for persons with celiac disease: a feasibility study for developing a gluten-free food database.

    Science.gov (United States)

    Agakidis, Charalampos; Karagiozoglou-Lampoudi, Thomais; Kalaitsidou, Marina; Papadopoulos, Theodoros; Savvidou, Afroditi; Daskalou, Efstratia; Dimitrios, Triantafyllou

    2011-12-01

    Inappropriate food labeling and unwillingness of food companies to officially register their own gluten-free products in the Greek National Food Intolerance Database (NFID) result in a limited range of processed food products available for persons with celiac disease (CDP). The objective of the study was to evaluate the feasibility of developing a gluten-free food product database based on the assessment of the gluten content in processed foods available for CDP. Gluten was assessed in 41 processed food products available for CDP. Group A consisted of 26 products for CDP included in the NFID, and group B contained 15 food products for CDP not registered in the NFID but listed in the safe lists of the local Celiac Association (CA). High-sensitivity ω-gliadin enzyme-linked immunosorbent assay (ELISA) was used for analysis. Gluten was lower than 20 ppm in 37 of 41 analyzed products (90.2%): in 24 of 26 (92.3%) products in group A and in 13 of 15 (86.7%) products in group B (P = .61). No significant difference was found between the 2 groups regarding gluten content. No product in either group contained gluten in excess of 100 ppm. Most of the analyzed products included in the Greek NFID or listed in the lists of the local CA, even those not officially labeled "gluten free," can be safely consumed by CDP. The use of commercially available ω-gliadin ELISA is able to identify those products that contain inappropriate levels of gluten, making feasible it to develop an integrated gluten-free processed food database.

  7. Use of Heavy Water (D2O in Developing Thermostable Recombinant p26 Protein Based Enzyme-Linked Immunosorbent Assay for Serodiagnosis of Equine Infectious Anemia Virus Infection

    Directory of Open Access Journals (Sweden)

    Harisankar Singha

    2014-01-01

    Full Text Available Thermostabilizing effect of heavy water (D2O or deuterium oxide has been demonstrated previously on several enzymes and vaccines like oral poliovirus vaccine and influenza virus vaccine. In view of the above observations, effect of heavy water on in situ thermostabilization of recombinant p26 protein on enzyme-linked immunosorbent assay (ELISA for serodiagnosis of equine infectious anemia virus (EIAV infection was investigated in the present study. The carbonate-bicarbonate coating buffer was prepared in 60% and 80% D2O for coating the p26 protein in 96-well ELISA plate and thermal stability was examined at 4°C, 37°C, 42°C, and 45°C over a storage time from 2 weeks to 10 months. A set of positive serum (n=12 consisting of strong, medium, and weak titer strength (4 samples in each category and negative serum (n=30 were assessed in ELISA during the study period. At each time point, ELISA results were compared with fresh plate to assess thermal protective effect of D2O. Gradual increase in the stabilizing effect of 80% D2O at elevated temperature (37°C < 42°C < 45°C was observed. The 80% D2O provides the thermal protection to rp26 protein in ELISA plate up to 2 months of incubation at 45°C. The findings of the present study have the future implication of adopting cost effective strategies for generating more heat tolerable ELISA reagents with extended shelf life.

  8. Milk progesterone enzyme-linked immunosorbent assay as a tool to investigate ovarian cyclicity of water buffaloes in relation to body condition score and milk production

    Directory of Open Access Journals (Sweden)

    Banu Turgish A

    2012-05-01

    Full Text Available Abstract Background Application of assisted reproductive technologies in buffaloes is limited to some extent by farmers’ inability to detect oestrus because of its poor expression. The present study aimed at investigating reliability of a milk progesterone enzyme-linked immunosorbent assay (ELISA to assess the ovarian cyclicity during post partum, oestrus and post-breeding periods in water buffaloes. Methods Progesterone concentrations were measured by an ELISA in milk of 23 postpartum buffaloes in relation to oestrus, pregnancy, body condition score (BCS and milk production. Two milk samples were taken at 10 days intervals, every month starting from day 30 and continued to day 150 post partum. BCS and milk production were recorded during sample collection. Milk samples from bred buffaloes were collected at Day 0 (day of breeding, Days 10–12 and Days 22–24. Defatted milk was preserved at −80°C until analysis. Pregnancy was confirmed by palpation per rectum on Days 70–90. Results Seventeen buffaloes had 47 ovulatory cycles, one to four in each, 13 were detected in oestrus once (28 % oestrus detection rate. Progesterone concentration ≥1 ng/ml in one of the two 10-day-interval milk samples reflected ovulation and corpus luteum formation. The intervals between calving to first luteal activity and to first detected oestrus varied from 41 to 123 days (n = 17 and 83 to 135 (n = 13 days, respectively. Eight buffaloes were bred in the course of the study and seven were found pregnant. These buffaloes had a progesterone profile of low (P P  Conclusions Milk progesterone ELISA is a reliable tool for monitoring ovarian cyclicity and good BCS may be an indicator of resuming cyclicity in water buffalo.

  9. Milk progesterone enzyme-linked immunosorbent assay as a tool to investigate ovarian cyclicity of water buffaloes in relation to body condition score and milk production.

    Science.gov (United States)

    Banu, Turgish A; Shamsuddin, Mohammed; Bhattacharjee, Jayonta; Islam, Mohammad F; Khan, Saiful I; Ahmed, Jalal U

    2012-05-03

    Application of assisted reproductive technologies in buffaloes is limited to some extent by farmers' inability to detect oestrus because of its poor expression. The present study aimed at investigating reliability of a milk progesterone enzyme-linked immunosorbent assay (ELISA) to assess the ovarian cyclicity during post partum, oestrus and post-breeding periods in water buffaloes. Progesterone concentrations were measured by an ELISA in milk of 23 postpartum buffaloes in relation to oestrus, pregnancy, body condition score (BCS) and milk production. Two milk samples were taken at 10 days intervals, every month starting from day 30 and continued to day 150 post partum. BCS and milk production were recorded during sample collection. Milk samples from bred buffaloes were collected at Day 0 (day of breeding), Days 10-12 and Days 22-24. Defatted milk was preserved at -80°C until analysis. Pregnancy was confirmed by palpation per rectum on Days 70-90. Seventeen buffaloes had 47 ovulatory cycles, one to four in each, 13 were detected in oestrus once (28 % oestrus detection rate). Progesterone concentration ≥1 ng/ml in one of the two 10-day-interval milk samples reflected ovulation and corpus luteum formation. The intervals between calving to first luteal activity and to first detected oestrus varied from 41 to 123 days (n = 17) and 83 to 135 (n = 13) days, respectively. Eight buffaloes were bred in the course of the study and seven were found pregnant. These buffaloes had a progesterone profile of low (progesterone ELISA is a reliable tool for monitoring ovarian cyclicity and good BCS may be an indicator of resuming cyclicity in water buffalo.

  10. Smart Drug Delivery System-Inspired Enzyme-Linked Immunosorbent Assay Based on Fluorescence Resonance Energy Transfer and Allochroic Effect Induced Dual-Modal Colorimetric and Fluorescent Detection.

    Science.gov (United States)

    Miao, Luyang; Zhu, Chengzhou; Jiao, Lei; Li, He; Du, Dan; Lin, Yuehe; Wei, Qin

    2018-02-06

    Numerous analytical techniques have been undertaken for the detection of protein biomarkers because of their extensive and significant applications in clinical diagnosis, whereas there are few strategies to develop dual-readout immunosensors to achieve more accurate results. To the best of our knowledge, inspired by smart drug delivery system (DDS), a novel pH-responsive modified enzyme-linked immunosorbent assay (ELISA) was innovatively developed for the first time, realizing dual-modal colorimetric and fluorescent detection of cardiac troponin I (cTnI). Curcumin (CUR) was elaborately selected as a reporter molecule, which played the same role of drugs in DDS based on the following considerations: (1) CUR can be used as a kind of pH indicator by the inherited allochroic effect induced by basic pH value; (2) the fluorescence of CUR can be quenched by certain nanocarriers as the acceptor because of the occurrence of fluorescence resonance energy transfer (FRET), while recovered by the stimuli of basic pH value, which can produce "signal-on" fluorescence detection. Three-dimensional MoS 2 nanoflowers (3D-MoS 2 NFs) were employed in immobilizing CUR to constitute a nanoprobe for the determination of cTnI by virtue of good biocompatibility, high absorption capacity, and fluorescence quench efficiency toward CUR. The proposed DDS-inspired ELISA offered dual-modal colorimetric and fluorescent detection of cTnI, thereby meeting the reliable and precise analysis requirements. We believe that the developed dual-readout ELISA will create a new avenue and bring innovative inspirations for biological detections.

  11. Management of bacterial kidney disease in Chinook Salmon hatcheries based on broodstock testing by enzyme-linked immunosorbent assay: A multiyear study

    Science.gov (United States)

    Munson, A. Douglas; Elliott, Diane G.; Johnson, Keith

    2010-01-01

    From the mid-1980s through the early 1990s, outbreaks of bacterial kidney disease (BKD) caused by Renibacterium salmoninarum continued in Chinook salmon Oncorhynchus tshawytscha in Idaho Department of Fish and Game (IDFG) hatcheries despite the use of three control methods: (1) injection of returning adult fish with erythromycin to reduce prespawning BKD mortality and limit vertical transmission of R. salmoninarum, (2) topical disinfection of green eggs with iodophor, and (3) prophylactic treatments of juvenile fish with erythromycin-medicated feed. In addition, programs to manage BKD through measurement of R. salmoninarum antigen levels in kidney tissues from spawning female Chinook salmon by an enzyme-linked immunosorbent assay (ELISA) were tested over 13–15 brood years at three IDFG hatcheries. The ELISA results were used for either (1) segregated rearing of progeny from females with high ELISA optical density (OD) values (usually ≥0.25), which are indicative of high R. salmoninarum antigen levels, or (2) culling of eggs from females with high ELISA OD values. The ELISA-based culling program had the most profound positive effects on the study populations. Mortality of juvenile fish during rearing was significantly lower at each hatchery for brood years derived from culling compared with brood years for which culling was not practiced. The prevalence of R. salmoninarum in juvenile fish, as evidenced by detection of the bacterium in kidney smears by the direct fluorescent antibody test, also decreased significantly at each hatchery. In addition, the proportions of returning adult females with kidney ELISA OD values of 0.25 or more decreased 56–85% for fish reared in brood years during which culling was practiced, whereas the proportions of ELISA-negative adults increased 55–58%. This management strategy may allow IDFG Chinook salmon hatcheries to reduce or eliminate prophylactic erythromycin-medicated feed treatments. We recommend using ELISA

  12. Effects of thermal processing on the enzyme-linked immunosorbent assay (ELISA) detection of milk residues in a model food matrix.

    Science.gov (United States)

    Downs, Melanie L; Taylor, Steve L

    2010-09-22

    Food products and ingredients are frequently tested for the presence of undeclared allergenic food residues (including milk) using commercial enzyme-linked immunosorbent assays (ELISAs). However, little is understood about the efficacy of these kits with thermally processed foods. This study evaluated the performance of three milk ELISA kits with a model food processed by several methods. A model food (pastry dough squares) was spiked with nonfat dry milk at several concentrations. The pastry squares were processed by boiling (100 °C for 2 min), baking (190 °C for 30 min), frying (190 °C for 2 min), and retorting (121 °C for 20 min with 17 psi overpressure). Samples were analyzed with three commercial ELISA kits: Neogen Veratox Total Milk, ELISA Systems β-lactoglobulin, and ELISA Systems casein. The detection of milk residues depended upon the type of processing applied to the food and the specific milk analyte targeted by the ELISA kit. Poor recoveries were obtained in all processed samples (2-10% of expected values) using the β-lactoglobulin kit. Better recoveries were obtained in boiled samples (44 and 59%, respectively) using the total milk and casein kits. However, these kits performed poorly with baked (9 and 21%) and fried (7 and 18%) samples. Moderate recoveries were observed in retorted samples (23 and 28%). The decreased detection in processed samples is likely due to protein modifications, including aggregation and Maillard reactions, which affect the solubility and immunoreactivity of the antigens detected by the ELISA methods. The observed decreases in ELISA detection of milk are dramatic enough to affect risk-assessment decisions. However, a lower detection of milk residues does not necessarily indicate decreased allergenicity. These ELISA kits are not acceptable for all applications, and users should understand the strengths and limitations of each method.

  13. A novel sandwich enzyme-linked immunosorbent assay with covalently bound monoclonal antibody and gold probe for sensitive and rapid detection of bovine β-lactoglobulin.

    Science.gov (United States)

    He, Shengfa; Li, Xin; Wu, Yong; Wu, Shandong; Wu, Zhihua; Yang, Anshu; Tong, Ping; Yuan, Juanli; Gao, Jinyan; Chen, Hongbing

    2018-06-01

    Bovine milk is a recognized allergenic food source with β-lactoglobulin (BLG) as its major allergen. Reliable detection of BLG epitopes can, therefore, be a useful marker for the presence of milk in processed food products, and for potential allergenicity. At the present, enzyme-linked immunosorbent assays (ELISA) for the detection of BLG are time-consuming and generally not specific to BLG IgE epitopes. In this study, the 1-ethyl-3-(3-dimethylaminopropyl)carbodiimide-activated anti-BLG IgE epitope monoclonal antibody (mAb 1G9) was covalently bound onto the KOH-treated microtiter plate surface. Using this mAb-bound plate in sandwich combination with biotinylated anti-BLG polyclonal antibody-labeled gold nanoparticles, a linear dynamic range between 31.25 and 64 × 10 3  ng mL -1 with a limit of detection for BLG of 0.49 ng mL -1 was obtained, which is 32 times wider and 16 times more sensitive than conventional sandwich ELISA (sELISA). Total recovery of BLG in spiked food samples was found, without matrix effects. Also in partially hydrolyzed infant formulas, the allergenic BLG residues were detected quantitatively. Compared with conventional and commercial BLG detection sELISAs, our sELISA is reliable, highly BLG epitope-specific, user-friendly, and time-saving and allows accurate detection of potentially allergenic residues in different types of processed foods. This improved sELISA protocol can be easily extended to detect other well-identified and characterized food allergens. Graphical abstract IgE epitope mAb-bound plate in sandwich combination with gold probe for sensitive and rapid detection of bovine β-lactoglobulin and its potentially allergenic residues.

  14. Indirect enzyme-linked immunosorbent assay method based on Streptococcus agalactiae rSip-Pgk-FbsA fusion protein for detection of bovine mastitis.

    Science.gov (United States)

    Bu, Ri-E; Wang, Jin-Liang; Wu, Jin-Hua; Xilin, Gao-Wa; Chen, Jin-Long; Wang, Hua

    2017-03-01

    The aim of this study was to establish a rapid and accurate method for the detection of the Streptococcus agalactiae antibody (SA-Ab) to determine the presence of the bovine mastitis (BM)-causative pathogen. The multi-subunit fusion protein rSip-Pgk-FbsA was prokaryotically expressed and purified. The triple activities of the membrane surface-associated proteins Sip, phosphoglycerate kinase (Pgk), and fibronectin (FbsA) were used as the diagnostic antigens to establish an indirect enzyme-linked immunosorbent assay (ELISA) method for the detection of SA-Ab in BM. The optimal antigen coating concentration was 2 μg/mL, the optimal serum dilution was 1:160, and the optimal dilution of the enzyme-labeled secondary antibody was 1:6000. The sensitivity, specificity, and repeatability tests showed that the method established in this study had no cross-reaction with antibodies to Streptococcus pyogenes, Escherichia coli, Staphylococcus aureus, and Staphylococcus epidermidis in the sera. The results of the sensitivity test showed that a positive result could be obtained even if the serum dilution reached 1:12,800, indicating the high sensitivity and good repeatability of the method. The positive coincidence rate of this method was 98.6%, which is higher than that of previous tests established with the Sip or Pgk mono-antigen fusion protein, respectively, demonstrating the relatively higher sensitivity of this newly established method. The detection rate for 389 clinical samples was 46.53%. The indirect ELISA method established in this study could provide a more accurate and reliable serological method for the rapid detection of S. agalactiae in cases of BM.

  15. Impact of grey zone sample testing by enzyme-linked immunosorbent assay in enhancing blood safety: Experience at a tertiary care hospital in North India.

    Science.gov (United States)

    Solanki, Archana; Singh, Abhay; Chaudhary, Rajendra

    2016-01-01

    Enzyme-linked immunosorbent assay (ELISA) used for screening blood donors for transfusion transmitted infections (TTIs) can sometimes fail to detect blood donors who are recently infected or possessing the low strength of pathogen. Estimation of a grey zone in ELISA testing and repeat testing of grey zone samples can further help in reducing the risks of TTI in countries where nucleic acid amplification testing for TTIs is not feasible. Grey zone samples with optical density (OD) lying between cut-off OD and 10% below the cut-off OD (cut-off OD × 0.9) were identified during routine ELISA testing. On performing repeat ELISA testing on grey zone samples in duplicate, the samples showing both OD value below grey zone were marked nonreactive, and samples showing one or both OD value in the grey zone were marked indeterminate. The samples on repeat testing showing one or both OD above cut-off value were marked positive. About 119 samples (77 for hepatitis B virus [HBV], 23 for human immunodeficiency virus [HIV], and 19 for hepatitis C virus [HCV]) were found to be in grey zone. On repeat testing of these samples in duplicate, 70 (58.8%) samples (45 for HBV, 12 for HIV, and 13 for HCV) were found to be reactive. Six (5%) samples (four for HBV, one for HIV, and one for HCV) were found to be indeterminate. Seventy donors initially screened negative, were found out to be potentially infectious on repeat grey zone testing. Thus, estimation of grey zone samples with repeat testing can further enhance the safety of blood transfusion.

  16. AN EVALUATION STUDY OF ENZYME-LINKED IMMUNOSORBENT ASSAY (ELISA USING RECOMBINANT PROTEIN GRA1 FOR DETECTION OF IGG ANTIBODIES AGAINTS TOXOPLASMA GONDII INFECTIONS

    Directory of Open Access Journals (Sweden)

    Nina Difla Muflikhah

    2017-08-01

    Full Text Available Toxoplasmosis is an infectious disease caused by Toxoplasma gondii, an intracellular protozoan parasite that live inside the cells of the reticulo endothelial and parenchymal cells of human and animals (mammals and birds. Some cases of toxoplasmosis usually have no symptoms, but in any cases caused severe symptoms, such as hydrocephalus, microcephalus, intracranial calcification, retinal damage, brain abscess, mental retardation, lymphadenopathy, and others. Its severe symptoms usually showed a long time after first exposure, except symptoms showed by congenital transmission caused by infected mother. Early diagnosis is important to prevent the illness but methods for toxoplasmosis screening are still too expensive for developing country. Enzyme-linked immunosorbent assay (ELISA allow the testing of a large number samples within short time frame and based on antibody or antigen detection. This study aimed to know the sensitivity and specificity of recombinat protein GRA1 as antigen using ELISA methods. We tested the sensitivity and spesificity of GRA1 protein as antigen in ELISA methods to diagnose toxoplasmosis and compared with ELISA Kit Commercial. Reliable laboratory testing is important to detect Toxoplasma gondii infection, and focused to improving the low cost and easy-to-use diagnostic instrument. Seventy sera collected and tested using both indirect ELISA, commercial ELISA kit and GRA1 protein coated as antigen. Fourty eight and fifty one samples showed positive IgG antibody result of ELISA-GRA1 and ELISA kit. Negative sample tested by ELISA-GRA1 was 22 samples and 19 sample tested by ELISA Kit. The sensitivity and specificity of GRA1-based on ELISA were 100% and 86.36%, positive prediction value (ppv was 94.11%. These data indicate that the recombinant protein GRA1 is a highly immunogenic protein in human toxoplasmosis and become a promising marker for the screening of toxoplasmosis.

  17. Evaluation of Chicken IgY Generated Against Canine Parvovirus Viral-Like Particles and Development of Enzyme-Linked Immunosorbent Assay and Immunochromatographic Assay for Canine Parvovirus Detection.

    Science.gov (United States)

    He, Jinxin; Wang, Yuan; Sun, Shiqi; Zhang, Xiaoying

    2015-11-01

    Immunoglobulin Y (IgY) antibodies were generated against canine parvovirus virus-like particles (CPV-VLPs) antigen using chickens. Anti-CPV-VLPs-IgY was extracted from hen egg yolk and used for developing enzyme-linked immunosorbent assay (ELISA) and immunochromatographic assay (ICA) for the detection of CPV in dog feces. The cutoff negative values for anti-CPV-VLPs-IgY were determined using negative fecal samples (already confirmed by polymerase chain reaction [PCR]). In both ELISA and ICA, there was no cross-reaction with other diarrheal pathogens. Thirty-four fecal samples were collected from dogs with diarrhea, of which 26.47% were confirmed as CPV-positive samples by PCR, while 29.41% and 32.35% of the samples were found to be positive by ELISA and ICA, respectively. The developed ELISA and ICA exhibited 97.06% and 94.12% conformity with PCR. Higher sensitivity and specificity were observed for IgY-based ELISA and ICA. Thus, they could be suitable for routine use in the diagnosis of CPV in dogs.

  18. Development and application of triple antibody sandwich enzyme-linked immunosorbent assays for begomovirus detection using monoclonal antibodies against Tomato yellow leaf curl Thailand virus.

    Science.gov (United States)

    Seepiban, Channarong; Charoenvilaisiri, Saengsoon; Warin, Nuchnard; Bhunchoth, Anjana; Phironrit, Namthip; Phuangrat, Bencharong; Chatchawankanphanich, Orawan; Attathom, Supat; Gajanandana, Oraprapai

    2017-05-30

    Tomato yellow leaf curl Thailand virus, TYLCTHV, is a begomovirus that causes severe losses of tomato crops in Thailand as well as several countries in Southeast and East Asia. The development of monoclonal antibodies (MAbs) and serological methods for detecting TYLCTHV is essential for epidemiological studies and screening for virus-resistant cultivars. The recombinant coat protein (CP) of TYLCTHV was expressed in Escherichia coli and used to generate MAbs against TYLCTHV through hybridoma technology. The MAbs were characterized and optimized to develop triple antibody sandwich enzyme-linked immunosorbent assays (TAS-ELISAs) for begomovirus detection. The efficiency of TAS-ELISAs for begomovirus detection was evaluated with tomato, pepper, eggplant, okra and cucurbit plants collected from several provinces in Thailand. Molecular identification of begomoviruses in these samples was also performed through PCR and DNA sequence analysis of the CP gene. Two MAbs (M1 and D2) were generated and used to develop TAS-ELISAs for begomovirus detection. The results of begomovirus detection in 147 field samples indicated that MAb M1 reacted with 2 begomovirus species, TYLCTHV and Tobacco leaf curl Yunnan virus (TbLCYnV), whereas MAb D2 reacted with 4 begomovirus species, TYLCTHV, TbLCYnV, Tomato leaf curl New Delhi virus (ToLCNDV) and Squash leaf curl China virus (SLCCNV). Phylogenetic analyses of CP amino acid sequences from these begomoviruses revealed that the CP sequences of begomoviruses recognized by the narrow-spectrum MAb M1 were highly conserved, sharing 93% identity with each other but only 72-81% identity with MAb M1-negative begomoviruses. The CP sequences of begomoviruses recognized by the broad-spectrum MAb D2 demonstrated a wider range of amino acid sequence identity, sharing 78-96% identity with each other and 72-91% identity with those that were not detected by MAb D2. TAS-ELISAs using the narrow-specificity MAb M1 proved highly efficient for the detection of

  19. Fluorescence-Based Multiplex Protein Detection Using Optically Encoded Microbeads

    Directory of Open Access Journals (Sweden)

    Dae Hong Jeong

    2012-03-01

    Full Text Available Potential utilization of proteins for early detection and diagnosis of various diseases has drawn considerable interest in the development of protein-based multiplex detection techniques. Among the various techniques for high-throughput protein screening, optically-encoded beads combined with fluorescence-based target monitoring have great advantages over the planar array-based multiplexing assays. This review discusses recent developments of analytical methods of screening protein molecules on microbead-based platforms. These include various strategies such as barcoded microbeads, molecular beacon-based techniques, and surface-enhanced Raman scattering-based techniques. Their applications for label-free protein detection are also addressed. Especially, the optically-encoded beads such as multilayer fluorescence beads and SERS-encoded beads are successful for generating a large number of coding.

  20. Calcium-Alginate-Inulin Microbeads as Carriers for Aqueous Carqueja Extract.

    Science.gov (United States)

    Balanč, Bojana; Kalušević, Ana; Drvenica, Ivana; Coelho, Maria Teresa; Djordjević, Verica; Alves, Vitor D; Sousa, Isabel; Moldão-Martins, Margarida; Rakić, Vesna; Nedović, Viktor; Bugarski, Branko

    2016-01-01

    Carqueja (Pterospartum tridentatum) is an endemic species and various bioactive compounds have been identified in its aqueous extract. The aim of this study was to protect the natural antioxidants from the aqueous extract of carqueja by encapsulation in Ca-alginate microbeads and Ca-alginate microbeads containing 10% and 20% (w/v) of inulin. The microbeads produced by electrostatic extrusion technique had an average diameter from 625 μm to 830 μm depending on the portion of inulin. The sphericity factor of the hydrogel microbeads had values between 0.014 and 0.026, while freeze dried microbeads had irregular shape, especially those with no excipient. The reduction in microbeads size after freeze drying process (expressed as shrinkage factor) ranged from 0.338 (alginate microbeads with 20% (w/v) of inulin) to 0.523 (plain alginate microbeads). The expressed radical scavenging activity against ABTS and DPPH radicals was found to be between 30% and 40% for encapsulated extract, while the fresh extract showed around 47% and 57% of radical scavenging activity for ABTS and DPPH radicals, respectively. The correlation between antioxidant activity and the total phenolic content were found to be positive (in both assay methods, DPPH and ABTS), which indicate that the addition of inulin didn't have influence on antioxidant activity. The presence of inulin reduced stiffness of the hydrogel, and protected bead structure from collapse upon freeze-drying. Alginate-inulin beads are envisaged to be used for delivery of aqueous P. tridentatum extract in functional food products. © 2015 Institute of Food Technologists®

  1. A New Enzyme-Linked Immunosorbent Assay for a Total Anti-T Lymphocyte Globulin Determination: Development, Analytical Validation, and Clinical Applications.

    Science.gov (United States)

    Montagna, Michela; La Nasa, Giorgio; Bernardo, Maria E; Piras, Eugenia; Avanzini, Maria A; Regazzi, Mario; Locatelli, Franco

    2017-06-01

    Anti-T lymphocyte globulin (ATLG) modulates the alloreactivity of T lymphocytes, reducing the risk of immunological posttransplant complications, in particular rejection and graft-versus-host disease, after allogeneic hematopoietic stem cell transplantation (HSCT). We developed and validated a new enzyme-linked immunosorbent assay (ELISA) method to measure serum levels of total ATLG and evaluate the pharmacokinetics (PK) of the drug in children with β-Thalassemia, receiving allogeneic HSCT. Diluted serum samples were incubated with Goat-anti-Rabbit IgG antibody coated on a microtiter plate and then, with Goat-anti-Human IgG labeled with horseradish peroxidase. After incubation and washings, substrate solution was added and absorbance was read at 492 nm. ATLG concentrations in samples were determined by interpolation from a standard curve (range: 200-0.095 ng/mL), prepared by diluting a known amount of ATLG in phosphate-buffered saline (PBS). Low, medium, and high-quality control concentrations were 1.56, 6.25, and 25 ng/mL, respectively. This method was developed and validated within the acceptance criteria in compliance with the Guidelines for a biological method validation: the sensitivity of the method was 0.095 ng/mL. We analyzed serum samples from 14 children with β-Thalassemia who received ATLG (Grafalon) at a dose of 10 mg/kg administered as intravenous (IV) infusion on days -5, -4, and -3 before HSCT (day 0). Blood sampling for PK evaluation was performed on days -5, -4, and -3 before and after drug infusion; and then from day -2 to +56. The median total ATLG levels pre-IVand post-IV were 0 and 118 mcg/mL on day -5; 85.9 and 199.2 mcg/mL on day -4; 153 and 270.9 mcg/mL on day -3, respectively. The median PK values of CL was 0.0029 (range: 0.0028-0.0057) L·kg·d, Vd was 0.088 (range: 0.025-0.448) L/kg and t1/2 was 20.2 (range: 5.8-50.2) days. These data suggest that given the marked interindividual variability of total ATLG disposition, the development of

  2. A comparison of titers of anti-Brucella antibodies of naturally infected and healthy vaccinated cattle by standard tube agglutination test, microtiter plate agglutination test, indirect hemagglutination assay, and indirect enzyme-linked immunosorbent assay

    Directory of Open Access Journals (Sweden)

    Anju Mohan

    2016-07-01

    Full Text Available Aim: We determined the antibody response in cattle naturally infected with brucellosis and normal healthy adult cattle vaccinated during calf hood with strain 19. Materials and Methods: The antibody titers were measured by standard tube agglutination test (STAT, microtiter plate agglutination test (MAT, indirect hemagglutination assay (IHA, and indirect enzyme-linked immunosorbent assay (iELISA as per standard protocols. Results: The mean STAT titers were 1.963±0.345 in infected cattle and 1.200±0.155 in healthy vaccinated cattle. The difference was extremely significant (p<0.0001. The mean MAT titers were 2.244±0.727 in infected cattle and 1.200±0.155 in healthy vaccinated cattle. The difference was very significant (p<0.005. The mean IHA titers in infected cattle were 2.284±0.574, and those in healthy vaccinated cattle were 1.200±0.155. The difference was extremely significant (p=0.0002. However, the difference in mean iELISA titers of infected cattle (1.3678±0.014 and healthy vaccinated cattle (1.367±0.014 was non-significant. The infected animals showed very high titers of agglutinating antibodies compared to the vaccinated animals. However, it cannot be ascertained whether these antibodies are due to vaccine or response to infection. Since the infected animals had been vaccinated earlier, the current infection may suggest that vaccination was unable to induce protective levels of antibody. The heightened antibody response after infection may also indicate a secondary immune response to the antigens common to the vaccine strain and wild Brucella organisms. Conclusion: The brucellosis infected animals showed very high titers of agglutinating antibodies compared to the vaccinated animals.

  3. Application of the Ceditest FMDV type O and FMDV-NS enzyme-linked immunosorbent assays for detection of antibodies against Foot-and-mouth disease virus in selected livestock and wildlife species in Uganda

    DEFF Research Database (Denmark)

    Ayebazibwe, Chrisostom; Mwiine, Frank Norbert; Balinda, Sheila Nina

    2012-01-01

    Diagnosis and control of Foot-and-mouth disease virus (FMDV) requires rapid and sensitive diagnostic tests. Two antibody enzyme-linked immunosorbent assay (ELISA) kits, Ceditest FMDV-NS for the detection of antibodies against the nonstructural proteins of all FMDV serotypes and Ceditest FMDV type O......, and selected samples were tested not only in serotype-specific ELISAs for antibodies against primarily FMDV serotype O, but also against other serotypes. The FMDV-NS assay detected far more positive samples (93%) than the FMDV type O assay (30%) in buffalo (P ... the South African Territories (SAT) serotypes, while the seroprevalence was generally comparable in cattle with antibodies against serotype O elicited by infection and/or vaccination. However, some districts had higher seroprevalence using the FMDV type O assay indicating vaccination without infection...

  4. Occurrence and Distribution of Pesticides in the St. Lucie River Watershed, South-Central Florida, 2000-01, Based on Enzyme-Linked Immunosorbent Assay (ELISA) Screening

    Science.gov (United States)

    Lietz, A.C.

    2003-01-01

    The St. Lucie River watershed is a valuable estuarine ecosystem and resource in south-central Florida. The watershed has undergone extensive changes over the last century because of anthropogenic activities. These activities have resulted in a complex urban and agricultural drainage network that facilitates the transport of contaminants, including pesticides, to the primary canals and then to the estuary. Historical data indicate that aquatic life criteria for selected pesticides have been exceeded. To address this concern, a reconnaissance was conducted to assess the occurrence and distribution of selected pesticides within the St. Lucie River watershed. Numerous water samples were collected from 37 sites among various land-use categories (urban/built-up, citrus, cropland/pastureland, and inte-grated). Samples were collected at inflow points to primary canals (C-23, C-24, and C-44) and at control structures along these canals from October 2000 to September 2001. Samples were screened for four pesticide classes (triazines, chloroacetanilides, chlorophenoxy compounds, and organophosphates) by using Enzyme-Linked Immunosorbent Assay (ELISA) screening. A temporal distribution of pesticides within the watershed was made based on samples collected at the integrated sites during different rainfall events between October 2000 and September 2001. Triazines were detected in 32 percent of the samples collected at the integrated sites. Chloroacetanilides were detected in 60 percent of the samples collected at the integrated sites, with most detections occurring at one site. Chlorophenoxy compounds were detected in 17 percent of the samples collected at the integrated sites. Organophosphates were detected in only one sample. A spatial distribution and range of concentration of pesticides at the 37 sampling sites in the watershed were determined among land-use categories. Triazine concentrations ranged from highest to lowest in the citrus, urban/built-up, and integrated areas

  5. Comparison of IgM Capture Enzyme- Linked Immunosorbent Assay (ELISA) using Inhouse method and commercially available MRL kit for serological confirmation of dengue infection

    International Nuclear Information System (INIS)

    Hapugoda, D.M.; De Silva R, Nilanthi; Abeywickreme, W.; Gunasena, Sunethra; Prithimala, L.D.; Jayawardene, S.L.G.J.; Kumari, Thamara

    2003-01-01

    Laboratory diagnosis of dengue infection is important for the management of the patients. In this study igM capture ELISA using an inhouse method and commercially available kit (MRL diagnostics,USA) was compared to detect diagnostic capability of Inhouse IgM ELISA for provision of diagnostic facilities to the public at an affordable cost. Eighty acute and convalescent serum samples were collected from serologically confirmed dengue patients. Serological confirmation of patients were performed by Haemagglutination Inhibition (HI) assay, gold standard assay for dengue on paired serum samples. All collected acute and convalescent sera were tested by IgM ELISA using the inhouse method and MRL kit. Antigen and conjugate for the inhouse IgM method were prepared in the laboratory. A cocktail of four dengue antigens containing 25 Antigen ELISA units of each type was prepared and used as the assay antigen. Conjugate was prepared using a serum sample with high dengue Anti flavi IgG antibody titre conjugated with Horseradish peroxidase. A prospective study of both IgM ELISA assays were performed using 113 acute sera collected from dengue suspected cases. Overall results showed that 46% and 52% acute sera collected from dengue confirmed patients were positive by inhouse ELISA assay and MRL kits respectively. In the prospective study done using acute sera collected from dengue suspected patients showed that 44% and 52% were positive by inhouse ELISA assay and MRL kits. There was no significant difference in positivity between these two assays. (P=0.18). Inhouse IgM ELISA can be used for provision of laboratory diagnosis of dengue virus infection more than 5 days. The assay is 10 times less costly than using MRL kits as assay antigen and conjugate can be prepared easily in the laboratory

  6. Validation of high throughput screening of human sera for detection of anti-PA IgG by Enzyme-Linked Immunosorbent Assay (ELISA) as an emergency response to an anthrax incident

    Science.gov (United States)

    Semenova, Vera A.; Steward-Clark, Evelene; Maniatis, Panagiotis; Epperson, Monica; Sabnis, Amit; Schiffer, Jarad

    2017-01-01

    To improve surge testing capability for a response to a release of Bacillus anthracis, the CDC anti-Protective Antigen (PA) IgG Enzyme-Linked Immunosorbent Assay (ELISA) was re-designed into a high throughput screening format. The following assay performance parameters were evaluated: goodness of fit (measured as the mean reference standard r2), accuracy (measured as percent error), precision (measured as coefficient of variance (CV)), lower limit of detection (LLOD), lower limit of quantification (LLOQ), dilutional linearity, diagnostic sensitivity (DSN) and diagnostic specificity (DSP). The paired sets of data for each sample were evaluated by Concordance Correlation Coefficient (CCC) analysis. The goodness of fit was 0.999; percent error between the expected and observed concentration for each sample ranged from −4.6% to 14.4%. The coefficient of variance ranged from 9.0% to 21.2%. The assay LLOQ was 2.6 μg/mL. The regression analysis results for dilutional linearity data were r2 = 0.952, slope = 1.02 and intercept = −0.03. CCC between assays was 0.974 for the median concentration of serum samples. The accuracy and precision components of CCC were 0.997 and 0.977, respectively. This high throughput screening assay is precise, accurate, sensitive and specific. Anti-PA IgG concentrations determined using two different assays proved high levels of agreement. The method will improve surge testing capability 18-fold from 4 to 72 sera per assay plate. PMID:27814939

  7. Validation of high throughput screening of human sera for detection of anti-PA IgG by Enzyme-Linked Immunosorbent Assay (ELISA) as an emergency response to an anthrax incident.

    Science.gov (United States)

    Semenova, Vera A; Steward-Clark, Evelene; Maniatis, Panagiotis; Epperson, Monica; Sabnis, Amit; Schiffer, Jarad

    2017-01-01

    To improve surge testing capability for a response to a release of Bacillus anthracis, the CDC anti-Protective Antigen (PA) IgG Enzyme-Linked Immunosorbent Assay (ELISA) was re-designed into a high throughput screening format. The following assay performance parameters were evaluated: goodness of fit (measured as the mean reference standard r 2 ), accuracy (measured as percent error), precision (measured as coefficient of variance (CV)), lower limit of detection (LLOD), lower limit of quantification (LLOQ), dilutional linearity, diagnostic sensitivity (DSN) and diagnostic specificity (DSP). The paired sets of data for each sample were evaluated by Concordance Correlation Coefficient (CCC) analysis. The goodness of fit was 0.999; percent error between the expected and observed concentration for each sample ranged from -4.6% to 14.4%. The coefficient of variance ranged from 9.0% to 21.2%. The assay LLOQ was 2.6 μg/mL. The regression analysis results for dilutional linearity data were r 2  = 0.952, slope = 1.02 and intercept = -0.03. CCC between assays was 0.974 for the median concentration of serum samples. The accuracy and precision components of CCC were 0.997 and 0.977, respectively. This high throughput screening assay is precise, accurate, sensitive and specific. Anti-PA IgG concentrations determined using two different assays proved high levels of agreement. The method will improve surge testing capability 18-fold from 4 to 72 sera per assay plate. Published by Elsevier Ltd.

  8. Preparation of anti-Sudan red monoclonal antibody and development of an indirect competitive enzyme-linked immunosorbent assay for detection of Sudan red in chilli jam and chilli oil.

    Science.gov (United States)

    Xu, Jing; Zhang, Yuanyang; Yi, Jian; Meng, Meng; Wan, Yuping; Feng, Caiwei; Wang, Shanliang; Lu, Xiao; Xi, Rimo

    2010-10-01

    Sudan dyes are banned to be used in food additives because of the carcinogenicity of their metabolites. A rapid and sensitive indirect competitive enzyme-linked immunosorbent assay (ELISA) was developed to detect the residues of Sudan dyes. Novel immunogen and coating antigen were synthesized via glutaraldehyde linking. The hapten-bovine serum albumin (BSA) was applied as immunogen and the hapten-ovalbumin (OVA) was served as coating antigen. The monoclonal antibody obtained showed high sensitivity to Sudan I with an IC(50) value of 1.7 μg L(-1) in buffer and was suitable to detect the residues of Sudan red in food products. The specificity of the assay was studied by measuring cross-reactivity of the antibody with the structurally related compounds of Sudan II (red (120%). Chilli jam and chilli oil samples spiked with Sudan dyes were analyzed by the method. The detection limit (LOD) of the ELISA method applied in chilli jam and chilli oil was 9.0 μg L(-1) and 19.6 μg L(-1), respectively. The recovery rates of Sudan-I in chilli oil and chilli jam were in the range of 80%-110% with coefficients of variation <25%. The intra-assay variation and inter-assay variation in buffer were both <9%.

  9. Evaluation of a Commercial Sandwich Enzyme-Linked Immunosorbent Assay for the Quantification of Beta-Casomorphin 7 in Yogurt Using Solid-Phase Extraction Coupled to Liquid Chromatography-Tandem Mass Spectrometry as the "Gold Standard" Method.

    Science.gov (United States)

    Nguyen, Duc Doan; Busetti, Francesco; Johnson, Stuart Keith; Solah, Vicky Ann

    2018-03-01

    This study investigated beta-casomorphin 7 (BCM7) in yogurt by means of LC-tandem MS (MS/MS) and enzyme-linked immunosorbent assay (ELISA) and use LC-MS/MS as the "gold standard" method to evaluate the applicability of a commercial ELISA. The level of BCM7 in milk obtained from ELISA analysis was much lower than that obtained by LC-MS/MS analysis and trended to increase during fermentation and storage of yogurt. Meanwhile, the results obtained from LC-MS/MS showed that BCM7 degraded during stages of yogurt processing, and its degradation may have been caused by X-prolyl dipeptidyl aminopeptidase activity. As a result, the commercial sandwich ELISA kit was not suitable for the quantification of BCM7 in fermented dairy milk.

  10. Improvement of an enzyme-linked immunosorbent assay for equine herpesvirus type 4 by using a synthetic-peptide 24-mer repeat sequence of glycoprotein G as an antigen

    Science.gov (United States)

    BANNAI, Hiroshi; NEMOTO, Manabu; TSUJIMURA, Koji; YAMANAKA, Takashi; MAEDA, Ken; KONDO, Takashi

    2015-01-01

    To increase the sensitivity of an enzyme-linked immunosorbent assay (ELISA) for equine herpesvirus type 4 (EHV-4) that uses a 12-mer peptide of glycoprotein G (gG4-12-mer: MKNNPIYSEGSL) [4], we used a longer peptide consisting of a 24-mer repeat sequence (gG4-24-mer: MKNNPIYSEGSLMLNVQHDDSIHT) as an antigen. Sera of horses experimentally infected with EHV-4 reacted much more strongly to the gG4-24-mer peptide than to the gG4-12-mer peptide. We used peptide ELISAs to test paired sera from horses naturally infected with EHV-4 (n=40). gG4-24-mer ELISA detected 37 positive samples (92.5%), whereas gG4-12-mer ELISA detected only 28 (70.0%). gG4-24-mer ELISA was much more sensitive than gG4-12-mer ELISA. PMID:26424485

  11. Improvement of an enzyme-linked immunosorbent assay for equine herpesvirus type 4 by using a synthetic-peptide 24-mer repeat sequence of glycoprotein G as an antigen.

    Science.gov (United States)

    Bannai, Hiroshi; Nemoto, Manabu; Tsujimura, Koji; Yamanaka, Takashi; Maeda, Ken; Kondo, Takashi

    2016-02-01

    To increase the sensitivity of an enzyme-linked immunosorbent assay (ELISA) for equine herpesvirus type 4 (EHV-4) that uses a 12-mer peptide of glycoprotein G (gG4-12-mer: MKNNPIYSEGSL) [4], we used a longer peptide consisting of a 24-mer repeat sequence (gG4-24-mer: MKNNPIYSEGSLMLNVQHDDSIHT) as an antigen. Sera of horses experimentally infected with EHV-4 reacted much more strongly to the gG4-24-mer peptide than to the gG4-12-mer peptide. We used peptide ELISAs to test paired sera from horses naturally infected with EHV-4 (n=40). gG4-24-mer ELISA detected 37 positive samples (92.5%), whereas gG4-12-mer ELISA detected only 28 (70.0%). gG4-24-mer ELISA was much more sensitive than gG4-12-mer ELISA.

  12. Color encoded microbeads-based flow cytometric immunoassay for polycyclic aromatic hydrocarbons in food

    International Nuclear Information System (INIS)

    Meimaridou, Anastasia; Haasnoot, Willem; Noteboom, Linda; Mintzas, Dimitrios; Pulkrabova, Jana; Hajslova, Jana; Nielen, Michel W.F.

    2010-01-01

    Food contamination caused by chemical hazards such as persistent organic pollutants (POPs) is a worldwide public health concern and requires continuous monitoring. The chromatography-based analysis methods for POPs are accurate and quite sensitive but they are time-consuming, laborious and expensive. Thus, there is a need for validated simplified screening tools, which are inexpensive, rapid, have automation potential and can detect multiple POPs simultaneously. In this study we developed a flow cytometry-based immunoassay (FCIA) using a color-encoded microbeads technology to detect benzo[a]pyrene (BaP) and other polycyclic aromatic hydrocarbons (PAHs) in buffer and food extracts as a starting point for the future development of rapid multiplex assays including other POPs in food, such as polychlorinated biphenyls (PCBs) and polybrominated diphenyl ethers (PBDEs). A highly sensitive assay for BaP was obtained with an IC 50 of 0.3 μg L -1 using a monoclonal antibody (Mab22F12) against BaP, similar to the IC 50 of a previously described enzyme-linked immunosorbent assay (ELISA) using the same Mab. Moreover, the FCIA was 8 times more sensitive for BaP compared to a surface plasmon resonance (SPR)-based biosensor immunoassay (BIA) using the same reagents. The selectivity of the FCIAs was tested, with two Mabs against BaP for 25 other PAHs, including two hydroxyl PAH metabolites. Apart from BaP, the FCIAs can detect PAHs such as indenol[1,2,3-cd]pyrene (IP), benz[a]anthracene (BaA), and chrysene (CHR) which are also appointed by the European Food Safety Authority (EFSA) as suitable indicators of PAH contamination in food. The FCIAs results were in agreement with those obtained with gas chromatography-mass spectrometry (GC-MS) for the detection of PAHs in real food samples of smoked carp and wheat flour and has great potential for the future routine application of this assay in a simplex or multiplex format in combination with simplified extraction procedure which are

  13. Influence of the incubation temperature and the batch components on the sensitivity of an enzyme-linked immunosorbent assay to detect Aujeszky's disease virus glycoprotein E (gE).

    Science.gov (United States)

    Cay, A B; Van der Stede, Y

    2010-12-01

    Although licensed batches of an enzyme-linked immunosorbent assay (ELISA) for Aujeszky's disease virus (ADV) were used, and the assays were performed within an ISO/IEC 17025 accredited quality control system, certain routine runs of the ADV ELISA were not validated using the quality system criteria, even when all technical parameters were controlled. Incubation at different temperatures and batch composition were identified as parameters that could result in non-validated assays/runs. Therefore, the effect of incubation temperature and batch composition on the analytical sensitivity of the ELISA was investigated. The World Organisation for Animal Health (OIE) standard reference serum ADV1 was diluted 1:8 and tested in 94 different glycoprotein E ELISA runs performed with different batches and different incubation temperatures. The incubation temperature and batch components had a significant influence on the qualitative result for the OIE standard reference serum. An incubation temperature of at least 22 degrees C was recommended, based on the results of this analysis. Which of the batch components caused these differences in sensitivity was not investigated further.

  14. Development of an enzyme-linked immunosorbent assay for detection of chicken osteocalcin and its use in evaluation of perch effects on bone remodeling in caged White Leghorns.

    Science.gov (United States)

    Jiang, S; Cheng, H W; Hester, P Y; Hou, J-F

    2013-08-01

    Osteocalcin (OC) is a sensitive biochemical marker for evaluating bone turnover in mammals. The role of avian OC is less clear because of the need for a chicken assay. Our objectives were to develop an assay using indirect competitive ELISA for detecting chicken serum OC and use the assay to examine the effects of perches on bone remodeling in caged hens. Anti-chicken OC polyclonal antibody was produced by immunization of rabbits with a recombinant OC from Escherichia coli. Chicken OC extracted from bone was used as a coated protein, and purified chicken OC was used for calibration. The limit of detection of the developed OC ELISA was 0.13 ng/mL. The intra- and interassay CV were housed in conventional cages with or without perches. Serum samples were collected from 71-wk-old White Leghorn hens subjected to 4 treatments. Treatment 1 was control chickens that never had access to perches during their life cycle. Treatment 2 chickens had perches during the pullet phase (0 to 16.9 wk of age), whereas treatment 3 chickens had perches only during the egg-laying phase of the life cycle (17 to 71 wk of age). Treatment 4 chickens always had access to perches (0 to 71 wk of age). Correlation between the 2 assays was 0.62 (P < 0.0001). Levels of serum OC using the developed chicken ELISA were higher than that detected using the Rat-Mid ELISA (P < 0.0001). Results from the chicken ELISA assay showed that hens with perch access had higher concentrations of serum OC than hens without perches during egg laying (P = 0.04). Pullet access to perches did not affect serum OC levels in 71-wk-old hens (P = 0.15). In conclusion, a chicken OC ELISA has been validated that is sensitive and accurate with adequate discriminatory power for measuring bone remodeling in chickens.

  15. Development of a simple gel permeation clean-up procedure coupled to a rapid disequilibrium enzyme-linked immunosorbent assay (ELISA) for the detection of Sudan I dye in spices and sauces.

    Science.gov (United States)

    Oplatowska, Michalina; Stevenson, Paul J; Schulz, Claudia; Hartig, Lutz; Elliott, Christopher T

    2011-09-01

    Sudan dyes have been found to be added to chilli and chilli products for illegal colour enhancement purposes. Due to the possible carcinogenic effect, they are not authorized to be used in food in the European Union or the USA. However, over the last few years, many products imported from Asian and African countries have been reported via the Rapid Alert System for Food and Feed in the European Union to be contaminated with these dyes. In order to provide fast screening method for the detection of Sudan I (SI), which is the most widely abused member of Sudan dyes family, a unique (20 min without sample preparation) direct disequilibrium enzyme-linked immunosorbent assay (ELISA) was developed. The assay was based on polyclonal antibodies highly specific to SI. A novel, simple gel permeation chromatography clean-up method was developed to purify extracts from matrices containing high amounts of fat and natural pigments, without the need for a large dilution of the sample. The assay was validated according to the Commission Decision 2002/657/EC criteria. The detection capability was determined to be 15 ng g(-1) in sauces and 50 ng g(-1) in spices. The recoveries found ranged from 81% to 116% and inter- and intra-assay coefficients of variation from 6% to 20%. The assay was used to screen a range of products (85 samples) collected from different retail sources within and outside the European Union. Three samples were found to contain high amounts (1,649, 722 and 1,461 ng g(-1)) of SI by ELISA. These results were confirmed by liquid chromatography-tandem mass spectrometry method. The innovative procedure allows for the fast, sensitive and high throughput screening of different foodstuffs for the presence of the illegal colorant SI.

  16. Discordant results obtained on testing sera from immunocompromised patients for cytomegalovirus IgG by enzyme-linked immunosorbent assay and radioimmunoassay

    Energy Technology Data Exchange (ETDEWEB)

    Booth, J C; El Mohandes, L; Tryhorn, Y S [London University (United Kingdom). St. George' s Hospital Medical School, Department of Medical Microbiology; Kangro, H O; Liu, K M [Saint Bartholomew' s Hospital, London (UK)

    1989-10-01

    The investigation of sera from immunocompromised patients for antibody to CMV by ELISA, RIA, immunofluorescence (IF) and complement-fixation (CF) revealed discrepancies that reflected differences in test specificity rather than sensitivity and suggested that for the long-term serological follow-up of such patients it would be advisable not to rely on only a single assay procedure. (author). 12 refs.; 8 figs.; 1 tab.

  17. The immune monitoring of pediatric organ transplants : potential role of soluble CD30 plasma measurement and granzyme B enzyme-linked immunosorbent assay

    OpenAIRE

    Truong, Quang Dinh

    2009-01-01

    Over the last half century, kidney and liver transplantation have been recognized as the treatment of choice for children with end-stage renal or liver failure. Greater understanding of the molecular mechanism of rejection and tolerance, as well as development of reliable assays that can measure accurately the status of the immune response, not only would help clinicians customize the prescription of immunosuppressive drugs in individual recipients, but also might contribute to optimization o...

  18. Implementation of an Enzyme Linked Immunosorbent Assay for the Quantification of Allergenic Egg Residues in Red Wines Using Commercially Available Antibodies

    Science.gov (United States)

    Koestel, Carole; Simonin, Céline; Belcher, Sandrine

    2016-01-01

    Abstract Since the early 2000s, labeling of potentially allergenic food components to protect people who suffer from food allergies is compulsory in numerous industrialized countries. In Europe, milk and egg components used during the winemaking process must be indicated on the label since July 1, 2012. Several ELISA procedures have been developed to detect allergenic residues in wines. However, the complexity of the wine matrix can inhibit the immunoenzymatic reaction. The aim of this study was to implement an ELISA assay for the detection of ovalbumin in red wines using commercially available antibodies. The specificity of the acquired antibodies and the absence of cross reactivity were assessed by immunoblotting and ELISA. An ELISA assay with a LOD of 14.2 μg/L and a LOQ of 56.4 μg/L of ovalbumin in aqueous solution was obtained. Differences in ELISA signals were observed when analyzing various fining agents, although reproducible conformation of the antigen could be reached for the comparison of ovalbumin and Ovicolle. The differences between samples in terms of pH could be leveled but the inhibition of the ELISA signal, positively correlated to the tannin content of the wines, could not be suppressed. Thus, standard curves of ovalbumin in several wines were obtained by relative quantification. The control steps and the difficulties encountered presented in this study should be considered by anybody working toward the development of ELISA assays for the detection of allergenic residues in complex food matrices. PMID:27356183

  19. Implementation of an Enzyme Linked Immunosorbent Assay for the Quantification of Allergenic Egg Residues in Red Wines Using Commercially Available Antibodies.

    Science.gov (United States)

    Koestel, Carole; Simonin, Céline; Belcher, Sandrine; Rösti, Johannes

    2016-08-01

    Since the early 2000s, labeling of potentially allergenic food components to protect people who suffer from food allergies is compulsory in numerous industrialized countries. In Europe, milk and egg components used during the winemaking process must be indicated on the label since July 1, 2012. Several ELISA procedures have been developed to detect allergenic residues in wines. However, the complexity of the wine matrix can inhibit the immunoenzymatic reaction. The aim of this study was to implement an ELISA assay for the detection of ovalbumin in red wines using commercially available antibodies. The specificity of the acquired antibodies and the absence of cross reactivity were assessed by immunoblotting and ELISA. An ELISA assay with a LOD of 14.2 μg/L and a LOQ of 56.4 μg/L of ovalbumin in aqueous solution was obtained. Differences in ELISA signals were observed when analyzing various fining agents, although reproducible conformation of the antigen could be reached for the comparison of ovalbumin and Ovicolle. The differences between samples in terms of pH could be leveled but the inhibition of the ELISA signal, positively correlated to the tannin content of the wines, could not be suppressed. Thus, standard curves of ovalbumin in several wines were obtained by relative quantification. The control steps and the difficulties encountered presented in this study should be considered by anybody working toward the development of ELISA assays for the detection of allergenic residues in complex food matrices. © 2016 The Authors. Journal of Food Science published by Wiley Periodicals, Inc. on behalf of Institute of Food Technologists.

  20. Detection of Shiga toxin-producing Escherichia coli by sandwich enzyme-linked immunosorbent assay using chicken egg yolk IgY antibodies

    Directory of Open Access Journals (Sweden)

    Yanil R Parma

    2012-06-01

    Full Text Available Enterohemorrhagic Escherichia coli (EHEC, a subset of Shiga toxin producing E. coli (STEC is associated with a spectrum of diseases that includes diarrhea, hemorrhagic colitis and a life-threatening hemolytic uremic syndrome (HUS. Regardless of serotype, Shiga toxins (Stx1 and/or Stx2 are uniformly expressed by all EHEC, and so exploitable targets for laboratory diagnosis of these pathogens. In this study, a sandwich ELISA for determination of Shiga toxin (Stx was developed using anti-Stx2 B subunit antibodies and its performance was compared with that of the Vero cell assay and a commercial immunoassay kit. Chicken IgY was used as capture antibody and a HRP-conjugated rabbit IgG as the detection antibody. The anti-Stx2B IgY was harvested from eggs laid by hens immunized with a recombinant protein fragment. Several parameters were tested in order to optimize the sandwich ELISA assay, including concentration of antibodies, type and concentration of blocking agent, and incubation temperatures. Supernatants from 42 STEC strains of different serotypes and stx variants, including stx2EDL933, stx2vha, stx2vhb, stx2g, stx1EDL933 and stx1d were tested. All Stx variants were detected by the sandwich ELISA, with a detection limit of 400 ng /ml Stx2. Twenty three strains negative for stx genes, including different bacteria species, showed no activity in Vero cell assay and produced negative results in ELISA, except for 2 strains. Our results show that anti-Stx2B IgY sandwich ELISA could be used in routine diagnosis as a rapid, specific and economic method for detection of Shiga toxin-producing E. coli.

  1. Detection of Shiga toxin-producing Escherichia coli by sandwich enzyme-linked immunosorbent assay using chicken egg yolk IgY antibodies

    Science.gov (United States)

    Parma, Y. R.; Chacana, P. A.; Lucchesi, P. M. A.; Rogé, A.; Granobles Velandia, C. V.; Krüger, A.; Parma, A. E.; Fernández-Miyakawa, M. E.

    2012-01-01

    Enterohemorrhagic Escherichia coli (EHEC), a subset of Shiga toxin producing E. coli (STEC) is associated with a spectrum of diseases that includes diarrhea, hemorrhagic colitis and a life-threatening hemolytic-uremic syndrome (HUS). Regardless of serotype, Shiga toxins (Stx1 and/or Stx2) are uniformly expressed by all EHEC, and so exploitable targets for laboratory diagnosis of these pathogens. In this study, a sandwich ELISA for determination of Shiga toxin (Stx) was developed using anti-Stx2B subunit antibodies and its performance was compared with that of the Vero cell assay and a commercial immunoassay kit. Chicken IgY was used as capture antibody and a HRP-conjugated rabbit IgG as the detection antibody. The anti-Stx2B IgY was harvested from eggs laid by hens immunized with a recombinant protein fragment. Several parameters were tested in order to optimize the sandwich ELISA assay, including concentration of antibodies, type and concentration of blocking agent, and incubation temperatures. Supernatants from 42 STEC strains of different serotypes and stx variants, including stx2EDL933, stx2vha, stx2vhb, stx2g, stx1EDL933, and stx1d were tested. All Stx variants were detected by the sandwich ELISA, with a detection limit of 115 ng/ml Stx2. Twenty three strains negative for stx genes, including different bacteria species, showed no activity in Vero cell assay and produced negative results in ELISA, except for two strains. Our results show that anti-Stx2B IgY sandwich ELISA could be used in routine diagnosis as a rapid, specific and economic method for detection of Shiga toxin-producing E. coli. PMID:22919675

  2. Enzyme-Linked Immunosorbent Assay Specific for (1→6) Branched, (1→3)-β-d-Glucan Detection in Environmental Samples

    OpenAIRE

    Milton, Donald K.; Alwis, K. Udeni; Fisette, Leslie; Muilenberg, Michael

    2001-01-01

    (1→3)-β-d-Glucans have been recognized as a potential causative agent responsible for bioaerosol-induced respiratory symptoms observed in both indoor and occupational environments. A specific enzyme immunoassay was developed to quantify (1→6) branched, (1→3)-β-d-glucans in environmental samples. The assay was based on the use of a high-affinity receptor (galactosyl ceramide) specific for (1→3)-β-d-glucans as a capture reagent and a monoclonal antibody specific for fungal cell wall β-d-glucans...

  3. Serodiagnosis of sporotrichosis infection in cats by enzyme-linked immunosorbent assay using a specific antigen, SsCBF, and crude exoantigens.

    Science.gov (United States)

    Fernandes, Geisa Ferreira; Lopes-Bezerra, Leila Maria; Bernardes-Engemann, Andréa Reis; Schubach, Tânia Maria Pacheco; Dias, Maria Adelaide Galvão; Pereira, Sandro Antonio; de Camargo, Zoilo Pires

    2011-01-27

    The main objective of this study is to standardize an ELISA for the diagnosis of feline sporotrichosis. Sporothrix schenckii is the etiological agent of human and animal sporotrichosis. Cats may act as reservoirs for S. schenckii and can transmit the infection to humans by a bite or scratch. There are few methods for the serological diagnosis of fungal diseases in animals. In this paper, an ELISA test for the diagnosis of cat sporotrichosis is proposed, which detects S. schenckii-specific antibodies in feline sera. Two different kinds of antigens were used: "SsCBF", a specific molecule from S. schenckii that consists of a Con A-binding fraction derived from a peptido-rhamnomannan component of the cell wall, and a S. schenckii crude exoantigen preparation. The ELISA was developed, optimized, and evaluated using sera from 30 cats with proven sporotrichosis (by culture isolation); 22 sera from healthy feral cats from a zoonosis center were used as negative controls. SsCBF showed 90% sensitivity and 96% specificity in ELISA; while crude exoantigens demonstrated 96% sensitivity and 98% specificity. The ELISA assay described here would be a valuable screening tool for the detection of specific S. schenckii antibodies in cats with sporotrichosis. The assay is inexpensive, quick to perform, easy to interpret, and permits the diagnosis of feline sporotrichosis. Copyright © 2010 Elsevier B.V. All rights reserved.

  4. The use of enzyme-linked immunosorbent assay (ELISA) for the diagnosis and monitoring of foot-and-mouth disease in the Philippines

    International Nuclear Information System (INIS)

    Verin, B.C.; Arvesu, R.M.

    2000-01-01

    The establishment and use of the indirect sandwich ELISA for the detection of foot-and-mouth disease (FMD) virus antigen sero-types O, A and C and the liquid phase blocking ELISA (LPB-ELISA) for antibody levels against similar FMD sero-types has been adopted for routine diagnosis at the FMD diagnostic laboratory, PAHC. A total of 552 epithelial samples and 4401 serum samples were tested starting 1995 to 1998. Out of 552, 84 (17.9%) were found negative and 468 (84.78%) diagnosed as positive for sero-types O and C (42% of the total positives). Within 4 years, 62 representative samples were sent to WRL for FMD for confirmation diagnosis. From 62 samples sent 54 (87%) were diagnosed as positive and 8 (12.9%) were negative. Serum samples received were either for diagnosis (71 samples), surveillance (3002 serum), post vaccination titre (1303 serum) and for the FAO/IAEA external quality assurance programme (25 samples) by the FAO/IAEA Co-ordinated Research Project on FMD. The assay has been a useful tool in the fast diagnosis and confirmation of FMD suspect cases and in the measurement of antibodies against FMDV in serum samples from all animals either vaccinated or infected. In the future, the assay will be use for potency testing of imported vaccines and for monitoring and surveillance purposes to show freedom from disease for the support documentation from OIE. (author)

  5. Evaluation of two Taenia solium cysticercal antigenic preparations (vesicular fluid and a glycoprotein fraction with affinity for lentil lectin for the immunodiagnosis of neurocysticercosis by enzyme-linked immunosorbent assay (ELISA

    Directory of Open Access Journals (Sweden)

    Lisandra Akemi Suzuki

    2011-06-01

    Full Text Available OBJECTIVE: To evaluate the performance of two antigenic preparations (vesicular fluid - VF and a glycoprotein fraction, LLa-Gp fraction, purified from a whole parasite extract by lentil lectin affinity chromatography from Taenia solium cysticerci for the immunodiagnosis of neurocysticercosis. METHOD: Fifty-six cerebrospinal fluid (CSF samples (22 from patients with neurocysticercosis and 34 from patients with other neurological disorders and 57 serum samples (22 from patients with neurocysticercosis, 18 from patients with other infections and 17 from presumably healthy persons were assayed for anticysticercal IgG antibodies with an enzyme-linked immunosorbent assay (ELISA. RESULTS: The VF ELISA showed 100% sensitivity and specificity in CSF and serum samples, whereas the sensitivity and specificity of the LLa-Gp ELISA were, respectively, 90.9% and 97.1%, with the CSF samples and 95.5% and 100% with serum samples. There was no significant difference in the sensitivity and specificity of the two antigenic preparations used to screen CSF and serum samples. CONCLUSION: Considering the complexity and high cost of obtaining the LLa-Gp fraction, VF could be more suitable for screening specific antibodies by ELISA in CSF and serum samples from patients with neurocysticercosis.

  6. Specific and sensitive enzyme-linked immunosorbent assays for analysis of residual allergenic food proteins in commercial bottled wine fined with egg white, milk, and nongrape-derived tannins.

    Science.gov (United States)

    Rolland, Jennifer M; Apostolou, Effie; de Leon, Maria P; Stockley, Creina S; O'Hehir, Robyn E

    2008-01-23

    Regulations introduced by the Food Standards Australia New Zealand in December 2002 require all wine and wine product labels in Australia to identify the presence of a processing aid, additive or other ingredient, which is known to be a potential allergen. The objective of this study was to establish sensitive assays to detect and measure allergenic proteins from commonly used processing aids in final bottled wine. Sensitive and specific enzyme-linked immunosorbent assays (ELISA) were developed and established for the proteins casein, ovalbumin, and peanut. Lower limits of detection of these proteins were 8, 1, and 8 ng/mL, respectively. A panel of 153 commercially available bottled Australian wines were tested by these ELISA, and except for two red wines known to contain added whole eggs, residuals of these food allergens were not detected in any wine. These findings are consistent with a lack of residual potentially allergenic egg-, milk-, or nut-derived processing aids in final bottled wine produced in Australia according to good manufacturing practice at a concentration that could cause an adverse reaction in egg, milk, or peanut/tree-nut allergic adult consumers.

  7. Performance and diagnostic usefulness of commercially available enzyme linked immunosorbent assay and rapid kits for detection of HIV, HBV and HCV in India

    Directory of Open Access Journals (Sweden)

    Maity Susmita

    2012-11-01

    Full Text Available Abstract Background HIV, HBV and HCV pose a major public health problem throughout the world. Detection of infection markers for these agents is a major challenge for testing laboratories in a resource poor setting. As blood transfusion is an important activity saving millions of live every year, it also carries a risk of transfusion transmissible infections caused by these fatal blood borne pathogens if the quality of testing is compromised. Conventional ELISA is regarded as the mostly used screening technique but due to limitations like high cost, unavailability in many blood banks and testing sites, involvement of costly instruments, time taking nature and requirement of highly skilled personnel for interpretation, rapid tests are gaining more importance and warrants comparison of performance. Results A comparative study between these two techniques has been performed using commercially available diagnostic kits to assess their efficacy for detection of HIV, HBV and HCV infections. Rapid kits were more efficient in specificity with synthetic antigens along with high PPV than ELISA in most cases. Comparison between different ELISA kits revealed that Microlisa HIV and Hepalisa (J. Mitra & Co. Pvt. Ltd.; ERBA LISA HIV1 + 2, ERBA LISA Hepatitis B and ERBA LISA HCV (Transasia Bio-medicals Ltd. gives uniform result with good performance in terms of sensitivity, specificity, PPV, NPV and efficiency, whereas, Microlisa HCV (J. Mitra & Co. Pvt. Ltd., Microscreen HBsAg ELISA and INNOVA HCV (Span Diagnostics Ltd. did not perform well. Rapid kits were also having high degree of sensitivity and specificity (100% except in HIV Comb and HCV Comb (J. Mitra & Co. Pvt. Ltd.. The kit efficiency didn’t vary significantly among different companies and lots in all the cases except for HCV ELISA showing statistically significant variation (p  Conclusions ELISA is a good screening assay for markers of HIV, HBV and HCV infections. Rapid tests are useful for

  8. Glycidyl methacrylate-co-N-vinyl-2-pyrrolidone coated polypropylene strips: Synthesis, characterization and standardization for dot-enzyme linked immunosorbent assay

    Energy Technology Data Exchange (ETDEWEB)

    Tyagi, Charu; Tomar, Lomas [Centre for Biomedical Engineering, Indian Institute of Technology, Delhi 110016 (India); Singh, Harpal [Centre for Biomedical Engineering, Indian Institute of Technology, Delhi 110016 (India)], E-mail: tyagicharu11@rediffmail.com

    2009-01-26

    Glycidyl methacrylate and N-vinyl-2-pyrrolidone (GMA-co-NVP) copolymers with various GMA:NVP ratios were synthesized by solution polymerization technique in toluene using 2,2'-azobisisobutyronitrile (AIBN) as free radical initiator and dip coated onto polypropylene strips. The copolymer composition in polymeric coatings was confirmed by proton NMR spectroscopy. Various techniques like FTIR, SEM and contact angle were used for surface characterization of the polymer coatings. These polymer coated strips were evaluated and standardized for their application in dot-ELISA in two steps. In first step, specificity, sensitivity and reproducibility of the assay on developed polymer coated strips was evaluated through a model system using rabbit anti-goat IgG, goat anti-rabbit IgG and goat anti-rabbit IgG HRP (horseradish peroxidase)-conjugate. Polymer coating with GMA-NVP mol% ratio of 78:22 was able to detect rabbit anti-goat IgG antibody at a concentration as low as 2 ng mL{sup -1} with 1% BSA as blocking agent using antispecies IgG peroxidase conjugate diluted 1500 times. In the second step, the sensitivity and specificity of the developed system was established with human blood and finally used to identify the source of mosquito blood meal which is an important parameter in epidemiological studies, particularly in determining the role of mosquito in malaria transmission. The time duration of standardized assay with developed polymer coated strips was cut down to one hour compared to the 3-4 h required in usual dot-ELISA.

  9. [Enzyme-linked immunosorbent assay (ELISA) for detection of antibodies to Salmonella Typhi lipopolysaccharide O and capsular polysaccharide Vi antigens in persons from outbreak of typhoid fever].

    Science.gov (United States)

    Rastawicki, Waldemar; Kałużewski, Stanisław

    2015-01-01

    The laboratory diagnosis of typhoid fever is dependent upon either isolation of S. Typhi from a clinical sample or the detection of raised titers of serum antibodies in the Widal test or the passive hemagglutination assay (PHA). In this study we evaluated the usefulness of ELISA for detection of antibodies to S. Typhi lipopolysaccharide O and capsular polysaccharide Vi antigens in the sera of persons from outbreak of typhoid fever. Fifteen serum samples from patients with laboratory confirmed typhoid fever and 140 sera from persons suspected for contact with typhoid fever patients from outbreak in 1974/75 in Poland were tested by ELISA. Additionally, as the control group, we tested 115 sera from blood donors for the presence of S. Typhi anti-LPS and anti-Vi antibodies. Anti-LPS and anti-Vi antibodies were detected in 80% and 53.3% of sera obtained from patients with laboratory confirmed typhoid fever, respectively. The high percentages of positive results in ELISA were also noted in the group of persons suspected for contact with typhoid fever patients (51.4% and 45%) but not in the group of blood donors (7.8% and 6.1%, respectively). The ELISA could be a useful tool for the serological diagnosis of typhoid fever in patients who have clinical symptoms but are culture negative, especially during massive outbreaks of typhoid fever.

  10. Rapid identification and susceptibility testing of uropathogenic microbes via immunosorbent ATP-bioluminescence assay on a microfluidic simulator for antibiotic therapy.

    Science.gov (United States)

    Dong, Tao; Zhao, Xinyan

    2015-02-17

    The incorporation of pathogen identification with antimicrobial susceptibility testing (AST) was implemented on a concept microfluidic simulator, which is well suited for personalizing antibiotic treatment of urinary tract infections (UTIs). The microfluidic device employs a fiberglass membrane sandwiched between two polypropylene components, with capture antibodies immobilized on the membrane. The chambers in the microfluidic device share the same geometric distribution as the wells in a standard 384-well microplate, resulting in compatibility with common microplate readers. Thirteen types of common uropathogenic microbes were selected as the analytes in this study. The microbes can be specifically captured by various capture antibodies and then quantified via an ATP bioluminescence assay (ATP-BLA) either directly or after a variety of follow-up tests, including urine culture, antibiotic treatment, and personalized antibiotic therapy simulation. Owing to the design of the microfluidic device, as well as the antibody specificity and the ATP-BLA sensitivity, the simulator was proven to be able to identify UTI pathogen species in artificial urine samples within 20 min and to reliably and simultaneously verify the antiseptic effects of eight antibiotic drugs within 3-6 h. The measurement range of the device spreads from 1 × 10(3) to 1 × 10(5) cells/mL in urine samples. We envision that the medical simulator might be broadly employed in UTI treatment and could serve as a model for the diagnosis and treatment of other diseases.

  11. Development of a highly sensitive and specific enzyme-linked immunosorbent assay (ELISA) for the detection of phenylethanolamine A in tissue and feed samples and confirmed by liquid chromatography tandem mass spectrometry (LC-MS/MS).

    Science.gov (United States)

    Cao, Biyun; He, Guangzhao; Yang, Hong; Chang, Huafang; Li, Shuqun; Deng, Anping

    2013-10-15

    Phenylethanolamine A (PA) is a new emerged β-adrenergic agonist illegally used as feed additives for growth promotion. In this study, a highly sensitive and specific indirect competitive enzyme-linked immunosorbent assay (ELISA) for the detection of PA in tissue and feed samples was developed and confirmed by liquid chromatography tandem mass spectrometry (LC-MS/MS). By reduction of nitryl group to amino group, the PA derivative was synthesized and coupled to carrier proteins with diazobenzidine method. The antisera obtained from four immunized rabbits were characterized in terms of sensitivity and specificity. All antisera displayed high sensitivity with IC50 values lower than 0.48 ng mL(-1). The most sensitive ELISA was established with IC50 and limit of detection (LOD) values of 0.049 ng mL(-1) and 0.003 ng mL(-1), respectively. The cross-reactivity (CR) values of the antisera with three frequently used β-adrenergic agonists (clenbuterol, salbutamol and ractopamine) were lesser than 0.39%; there was no CR of the antisera with other six compounds including two structurally related substances (isoproterenol, phenylephrine). To investigate the accuracy and precision of the assay, swine kidney, liver, meat and feed samples were fortified with PA at different content and analyzed by ELISA. Acceptable recovery rates of 92.2-113.7% and intra-assay coefficients of variation of 3.8-10.9% (n=3) were achieved. Seven spiked samples were simultaneously analyzed by ELISA and LC-MS/MS. There was a high correlation coefficient of 0.9956 (n=7) between the two methods. The proposed ELISA proven to be a feasible quantitative/screening method for PA analysis in tissue and feed samples with the properties of high sensitivity and specificity, high sample throughput and low expensive. © 2013 Elsevier B.V. All rights reserved.

  12. Accuracy of molecular diagnostics in pemphigus and bullous pemphigoid: comparison of commercial and modified mosaic indirect immunofluorescence tests as well as enzyme-linked immunosorbent assays.

    Science.gov (United States)

    Gornowicz-Porowska, Justyna; Seraszek-Jaros, Agnieszka; Bowszyc-Dmochowska, Monika; Kaczmarek, Elżbieta; Pietkiewicz, Paweł; Bartkiewicz, Paweł; Dmochowski, Marian

    2017-02-01

    Pemphigus and bullous pemphigoid (BP) are identified by autoantibodies (abs) against desmoglein 1, 3 (DSG1/3) and BP180/BP230, respectively. A novel mosaic to indirect immunofluorescence (IIF) using purified BP180 recombinant proteins spotted on slide and transfected cells expressing BP230, DSG1, DSG3 is available. The commercial (IgG detection) and modified (IgG4 detection) mosaic for indirect immunofluorescence (IIFc - IIF commercial, IIFm - IIF modified) and IgG ELISAs were evaluated in pemphigus and bullous pemphigoid (BP) molecular diagnostics. To compare diagnostic accuracy of commercial (IgG detection) and modified (IgG4 detection) mosaic IIF assay and to examine the diagnostic value of ELISAs in relation to mosaic IIF in routine laboratory diagnostics of pemphigus and BP. Sera from 37 BP and 19 pemphigus patients were studied. Associations between tests were assessed using Fisher's exact test. There are associations between the positive/negative samples detected by IIFc with desmoglein1 (DSG1)/desmoglein3 (DSG3)/BP230 transfected cells and ELISAs and no association between anti-BP180 IgG detection by IIFc and ELISA. IIFm with DSG1 and DSG3 showed both 100% sensitivity and 100% and 78% specificity, respectively, and 100% and 83% positive predictive value in relation to IIFc. IIFm with BP230 had 87% specificity, 55% sensitivity, whereas IIFm with BP180 had a 100% sensitivity and 13% specificity in relation to IIFc. The IIFc with DSG1/DSG3/BP230 transfected cells, excluding BP180 spots, is an alternative method to ELISA in pemphigus/BP diagnostics. IgG4 antibodies, both pathogenically and diagnostically important, are inconsistently detectable with IIFm.

  13. Accuracy of molecular diagnostics in pemphigus and bullous pemphigoid: comparison of commercial and modified mosaic indirect immunofluorescence tests as well as enzyme-linked immunosorbent assays

    Directory of Open Access Journals (Sweden)

    Justyna Gornowicz-Porowska

    2017-02-01

    Full Text Available Introduction : Pemphigus and bullous pemphigoid (BP are identified by autoantibodies (abs against desmoglein 1, 3 (DSG1/3 and BP180/BP230, respectively. A novel mosaic to indirect immunofluorescence (IIF using purified BP180 recombinant proteins spotted on slide and transfected cells expressing BP230, DSG1, DSG3 is available. The commercial (IgG detection and modified (IgG4 detection mosaic for indirect immunofluorescence (IIFc – IIF commercial, IIFm – IIF modified and IgG ELISAs were evaluated in pemphigus and bullous pemphigoid (BP molecular diagnostics. Aim : To compare diagnostic accuracy of commercial (IgG detection and modified (IgG4 detection mosaic IIF assay and to examine the diagnostic value of ELISAs in relation to mosaic IIF in routine laboratory diagnostics of pemphigus and BP. Material and methods : Sera from 37 BP and 19 pemphigus patients were studied. Associations between tests were assessed using Fisher’s exact test. Results: There are associations between the positive/negative samples detected by IIFc with desmoglein1 (DSG1/desmoglein3 (DSG3/BP230 transfected cells and ELISAs and no association between anti-BP180 IgG detection by IIFc and ELISA. IIFm with DSG1 and DSG3 showed both 100% sensitivity and 100% and 78% specificity, respectively, and 100% and 83% positive predictive value in relation to IIFc. IIFm with BP230 had 87% specificity, 55% sensitivity, whereas IIFm with BP180 had a 100% sensitivity and 13% specificity in relation to IIFc. Conclusions : The IIFc with DSG1/DSG3/BP230 transfected cells, excluding BP180 spots, is an alternative method to ELISA in pemphigus/BP diagnostics. IgG4 antibodies, both pathogenically and diagnostically important, are inconsistently detectable with IIFm.

  14. Performance and diagnostic usefulness of commercially available enzyme linked immunosorbent assay and rapid kits for detection of HIV, HBV and HCV in India.

    Science.gov (United States)

    Maity, Susmita; Nandi, Srijita; Biswas, Subrata; Sadhukhan, Salil Kumar; Saha, Malay Kumar

    2012-11-26

    HIV, HBV and HCV pose a major public health problem throughout the world. Detection of infection markers for these agents is a major challenge for testing laboratories in a resource poor setting. As blood transfusion is an important activity saving millions of live every year, it also carries a risk of transfusion transmissible infections caused by these fatal blood borne pathogens if the quality of testing is compromised. Conventional ELISA is regarded as the mostly used screening technique but due to limitations like high cost, unavailability in many blood banks and testing sites, involvement of costly instruments, time taking nature and requirement of highly skilled personnel for interpretation, rapid tests are gaining more importance and warrants comparison of performance. A comparative study between these two techniques has been performed using commercially available diagnostic kits to assess their efficacy for detection of HIV, HBV and HCV infections. Rapid kits were more efficient in specificity with synthetic antigens along with high PPV than ELISA in most cases. Comparison between different ELISA kits revealed that Microlisa HIV and Hepalisa (J. Mitra & Co. Pvt. Ltd.); ERBA LISA HIV1 + 2, ERBA LISA Hepatitis B and ERBA LISA HCV (Transasia Bio-medicals Ltd.) gives uniform result with good performance in terms of sensitivity, specificity, PPV, NPV and efficiency, whereas, Microlisa HCV (J. Mitra & Co. Pvt. Ltd.), Microscreen HBsAg ELISA and INNOVA HCV (Span Diagnostics Ltd.) did not perform well. Rapid kits were also having high degree of sensitivity and specificity (100%) except in HIV Comb and HCV Comb (J. Mitra & Co. Pvt. Ltd.). The kit efficiency didn't vary significantly among different companies and lots in all the cases except for HCV ELISA showing statistically significant variation (p bank. For availability of quality commercial diagnostic assays, evaluation of kit may be helpful.

  15. Utilizing microfluidics to synthesize polyethylene glycol microbeads for Förster resonance energy transfer based glucose sensing

    Science.gov (United States)

    Kantak, Chaitanya; Zhu, Qingdi; Beyer, Sebastian; Bansal, Tushar; Trau, Dieter

    2012-01-01

    Here, we utilize microfluidic droplet technology to generate photopolymerizeable polyethylene glycol (PEG) hydrogel microbeads incorporating a fluorescence-based glucose bioassay. A microfluidic T-junction and multiphase flow of fluorescein isothiocyanate dextran, tetramethyl rhodamine isothiocyanate concanavalin A, and PEG in water were used to generate microdroplets in a continuous stream of hexadecane. The microdroplets were photopolymerized mid-stream with ultraviolet light exposure to form PEG microbeads and were collected at the outlet for further analysis. Devices were prototyped in PDMS and generated highly monodisperse 72 ± 2 μm sized microbeads (measured after transfer into aqueous phase) at a continuous flow rate between 0.04 ml/h—0.06 ml/h. Scanning electron microscopy analysis was conducted to analyze and confirm microbead integrity and surface morphology. Glucose sensing was carried out using a Förster resonance energy transfer (FRET) based assay. A proportional fluorescence intensity increase was measured within a 1–10 mM glucose concentration range. Microfluidically synthesized microbeads encapsulating sensing biomolecules offer a quick and low cost method to generate monodisperse biosensors for a variety of applications including cell cultures systems, tissue engineering, etc. PMID:22655010

  16. Enabling Microliquid Chromatography by Microbead Packing of Microchannels

    Science.gov (United States)

    Balvin, Manuel; Zheng, Yun

    2014-01-01

    The microbead packing is the critical element required in the success of on-chip microfabrication of critical microfluidic components for in-situ analysis and detection of chiral amino acids. In order for microliquid chromatography to occur, there must be a stationary phase medium within the microchannel that interacts with the analytes present within flowing fluid. The stationary phase media are the microbeads packed by the process discussed in this work. The purpose of the microliquid chromatography is to provide a lightweight, low-volume, and low-power element to separate amino acids and their chiral partners efficiently to understand better the origin of life. In order to densely pack microbeads into the microchannels, a liquid slurry of microbeads was created. Microbeads were extracted from a commercially available high-performance liquid chromatography column. The silica beads extracted were 5 microns in diameter, and had surface coating of phenyl-hexyl. These microbeads were mixed with a 200- proof ethanol solution to create a microbead slurry with the right viscosity for packing. A microfilter is placed at the outlet via of the microchannel and the slurry is injected, then withdrawn across a filter using modified syringes. After each injection, the channel is flushed with ethanol to enhance packing. This cycle is repeated numerous times to allow for a tightly packed channel of microbeads. Typical microbead packing occurs in the macroscale into tubes or channels by using highly pressurized systems. Moreover, these channels are typically long and straight without any turns or curves. On the other hand, this method of microbead packing is completed within a microchannel 75 micrometers in diameter. Moreover, the microbead packing is completed into a serpentine type microchannel, such that it maximizes microchannel length within a microchip. Doing so enhances the interactions of the analytes with the microbeads to separate efficiently amino acids and amino acid

  17. Enzyme-Linked Immunosorbent Assay Testing of Shoots Grown In Vitro and the Use of Immunocapture-Reverse Transcription-Polymerase Chain Reaction Improve the Detection of Prunus necrotic ringspot virus in Rose.

    Science.gov (United States)

    Moury, B; Cardin, L; Onesto, J P; Candresse, T; Poupet, A

    2000-05-01

    We developed and evaluated two different methods to improve the detection of the most prevalent virus of rose in Europe, Prunus necrotic ring-spot virus (PNRSV). Immunocapture-reverse transcription-polymerase chain reaction was estimated to be about 100 times more sensitive than double-antibody sandwich-enzyme-linked immunosorbent assay (DAS-ELISA) and showed an equivalent specificity. Based on the observation that PNRSV multiplies actively in young growing tissues (axillary shoots and cuttings), an in vitro culture method allowing rapid (about 15 days) and homogeneous development of dormant axillary buds with high virus titers was standardized. ELISA tests of these young shoots showed, in some cases, a 10(4) to 10(5) increase in sensitivity in comparison to adjacent leaf tissues from the rose mother plants. Between 21 and 98% (depending on the season) more samples were identified as positive by using ELISA on samples from shoot tips grown in vitro rather than on leaves collected directly from the PNRSV-infected mother plants. This simple method of growing shoot tips in vitro improved the confidence in the detection of PNRSV and eliminated problems in sampling appropriate tissues.

  18. Comparison of immunofluorescence and enzyme-linked immunosorbent assay and immunoglobulin G avidity techniques for screening of anti: Toxoplasma antibodies among single serum sample pregnant women in Tabriz, Iran

    Directory of Open Access Journals (Sweden)

    Mehrangiz Rajaii

    2015-01-01

    Full Text Available Background: Congenital toxoplasmosis is that pregnant women acquire the infection during gestation; diagnosis of the acute infection during pregnancy is a complex subject of maternal toxoplasmosis. Thus, the presence of immunoglobulin G (IgG and/or IgM Toxoplasma antibodies in a single serum sample drawn during gestation cannot be used to define whether the infection was recently acquired or chronic. Materials and Methods: At this cross-sectional descriptive study, sera of 391 pregnant women examined and compared. They were in an age range of 21-35 years, referred by gynecologists and infectious disease specialists, during March 2012-April 2013. They have referred, 215 (54.98%, 102 (26%, 74 (18.92% in the first, second and third trimesters of gestation, respectively. For each of them, a questionnaire was completed and serum samples were prepared in an equal condition, examined according to the procedures of indirect immunofluorescence (IIF, enzyme-linked immunosorbent assay (ELISA and IgG Avidity techniques. Results: We have found 111 (28.38% seronegative and 280 (71.61% seropositive cases by IIF and 124 (31.70% seronegative, 267 (68.28% seropositive cases by ELISA. The IgG avidity test confirmed 45 (69.23% and 7 (10.76% doubtful cases of IgM test in IIF and ELISA techniques. Conclusions: This study highlights how to manage pregnant women with toxoplasmosis, especially in a single serum sample condition.

  19. Levels of house dust mite-specific serum immunoglobulin E (IgE) in different cat populations using a monoclonal based anti-IgE enzyme-linked immunosorbent assay.

    Science.gov (United States)

    Bexley, Jennifer; Hogg, Janice E; Hammerberg, Bruce; Halliwell, Richard E W

    2009-10-01

    Levels of serum immunoglobulin E (IgE) specific for the house dust mites (HDMs) Dermatophagoides farinae (DF) and Dermatophagoides pteronyssinus (DP) in 58 cats with clinical signs suggestive of atopic dermatitis (allergic dermatitis cats), 52 cats with no history of allergic or immunological disease (nonallergic cats) and 26 specific pathogen-free (SPF) cats were measured using a monoclonal anti-IgE enzyme-linked immunosorbent assay. Reactivity to both native and reduced HDM allergens was compared. SPF cats had significantly lower levels of HDM-specific serum IgE than cats with allergic dermatitis and nonallergic cats. The difference in levels of HDM-specific IgE in the serum of cats with allergic dermatitis and nonallergic cats was significant for native DF allergen, but not for native DP allergen or reduced HDM allergens. The results suggest that DF in its native form may be a significant allergen in cats with allergic dermatitis. The clinical relevance of these reactions, however, remains to be proven.

  20. Development of an indirect enzyme-linked immunosorbent assay (ELISA) to differentiate antibodies against wild-type porcine reproductive and respiratory syndrome from the vaccine strain TJM-F92 based on a recombinant Nsp2 protein.

    Science.gov (United States)

    Wang, X X; Wang, F X; Li, Z G; Wen, Y J; Wang, X; Song, N; Wu, H

    2018-01-01

    An accurate ELISA method to differentiate pigs infected with wild-type porcine reproductive and respiratory syndrome (PRRSV) strains from vaccinated ones would help to monitor PRRSV vaccination compliance. The recombinant protein GST-d120aa derived from the continuous deletion of 120 amino acids in the non-structural protein 2 region of the modified-live vaccine strain TJM-F92 was used to develop an indirect enzyme-linked immunosorbent assay (d120-ELISA) for differentiating serum antibodies against TJM-F92 from other PRRSV strains. At the optimized cut-off value which was calculated at an S/P of 0.25, it yielded a sensitivity of 90.7% and a specificity of 95.1%. Cross-reactivity tests suggested that the d120-ELISA was PRRSV-specific. Coefficient of variations of the repeatability tests ranged between 1.41-17.02%. The results suggest that the d120-ELISA is suitable for differentiating animals infected with wild-type strains from those immunized with MLV TJM-F92. Copyright © 2017. Published by Elsevier B.V.

  1. Development of enzyme-linked immunosorbent assay (ELISA) for glutathione S-transferase (GST-S) protein in the intertidal copepod Tigriopus japonicus and its application for environmental monitoring.

    Science.gov (United States)

    Rhee, Jae-Sung; Kim, Bo-Mi; Jeong, Chang-Bum; Leung, Kenneth Mei Yee; Park, Gyung Soo; Lee, Jae-Seong

    2013-11-01

    To utilize the GST-S protein as a useful biomarker for environmental contamination, we developed a polyclonal antibody-based enzyme-linked immunosorbent assay (ELISA) in the intertidal copepod Tigriopus japonicus. Two polyclonal antibodies, TJ-GST-S1 and TJ-GST-S2, were raised against two TJ-GST-S synthetic peptides. Also a recombinant TJ-GST-S protein was purified as a standard for ELISA development. Each polyclonal antibody was tested by Western blot analysis and indirect ELISA. Of two polyclonal antibodies, TJ-GST-S2 ELISA was further employed due to its wide range of detection and the limit of specificity compared to those of TJ-GST-S1 ELISA system. After exposure to 4 metals (Ag, As, Cd, and Cu) to T. japonicus, the amount of TJ-GST-S protein was significantly elevated in a concentration-dependent manner. Also, TJ-GST-S protein was upregulated at relative high concentrations of B[α]P, PCB, and TBT. In this paper, we suggest that T. japonicas ELISA for TJ-GST-S2 is useful as a potential indicator system for marine contaminants. Copyright © 2013 Elsevier Ltd. All rights reserved.

  2. Expression of Leptin and Visfatin in Gingival Tissues of Chronic Periodontitis With and Without Type 2 Diabetes Mellitus: A Study Using Enzyme-Linked Immunosorbent Assay and Real-Time Polymerase Chain Reaction.

    Science.gov (United States)

    Ghallab, Noha A; Amr, Eman M; Shaker, Olfat G

    2015-07-01

    The aim of this study is to investigate the protein and gene expression of leptin and visfatin in gingival tissue from patients with chronic periodontitis (CP), patients with CP and type 2 diabetes mellitus (T2DM), and healthy individuals. The study includes 50 individuals: 10 healthy individuals, 20 patients with CP, and 20 patients with CP and T2DM. Plaque index, gingival index, probing depth, and clinical attachment loss were measured, and gingival biopsies were obtained. Leptin and visfatin protein expression in gingival tissues was determined using enzyme-linked immunosorbent assay, and messenger RNA (mRNA) expression was measured via real-time polymerase chain reaction. The highest leptin mRNA and protein expression was observed in the control group and was significantly (P ≤0.05) different from the CP and CP+T2DM groups. Gingival tissues from patients with CP and T2DM had a significant increase in visfatin and a decrease in leptin gene and protein expression (P <0.05) compared with both controls and patients with CP. Expression of leptin and visfatin in the gingival tissues suggests a possible role for these adipokines in the pathogenesis of CP and T2DM.

  3. Impacts of Extraction Methods in the Rapid Determination of Atrazine Residues in Foods using Supercritical Fluid Chromatography and Enzyme-Linked Immunosorbent Assay: Microwave Solvent vs. Supercritical Fluid Extractions

    Directory of Open Access Journals (Sweden)

    Mohamed H. El-Saeid

    2005-01-01

    Full Text Available It is an accepted fact that many food products that we eat today have the possibility of being contaminated by various chemicals used from planting to processing. These chemicals have been shown to cause illnesses for which some concerned government agencies have instituted regulatory mechanisms to minimize the risks and the effects on humans. It is for these concerns that reliable and accurate rapid determination techniques are needed to effect proper regulatory standards for the protection of people's nutritional health. This paper, therefore, reports the comparative evaluation of the extraction methods in the determination of atrazine (commonly used in agricultural as a herbicide residues in foods using supercritical fluid chromatography (SFC and enzyme-linked immunosorbent assay (ELISA techniques. Supercritical fluid extraction (SFE and microwave solvent extraction (MSE methods were used to test samples of frozen vegetables, fruit juice, and jam from local food markets in Houston. Results showed a high recovery percentage of atrazine residues using supercritical fluid coupled with ELISA and SFC than with MSE. Comparatively, however, atrazine was detected 90.9 and 54.5% using SFC and ELISA techniques, respectively. ELISA technique was, however, less time consuming, lower in cost, and more sensitive with low detection limit of atrazine residues than SFC technique.

  4. An Enzyme-Linked Immunosorbent Spot Assay Measuring Borrelia burgdorferi B31-Specific Interferon Gamma-Secreting T Cells Cannot Discriminate Active Lyme Neuroborreliosis from Past Lyme Borreliosis: a Prospective Study in the Netherlands.

    Science.gov (United States)

    van Gorkom, T; Sankatsing, S U C; Voet, W; Ismail, D M; Muilwijk, R H; Salomons, M; Vlaminckx, B J M; Bossink, A W J; Notermans, D W; Bouwman, J J M; Kremer, K; Thijsen, S F T

    2018-04-01

    Two-tier serology testing is most frequently used for the diagnosis of Lyme borreliosis (LB); however, a positive result is no proof of active disease. To establish a diagnosis of active LB, better diagnostics are needed. Tests investigating the cellular immune system are available, but studies evaluating the utility of these tests on well-defined patient populations are lacking. Therefore, we investigated the utility of an enzyme-linked immunosorbent spot (ELISpot) assay to diagnose active Lyme neuroborreliosis. Peripheral blood mononuclear cells (PBMCs) of various study groups were stimulated by using Borrelia burgdorferi strain B31 and various recombinant antigens, and subsequently, the number of Borrelia -specific interferon gamma (IFN-γ)-secreting T cells was measured. We included 33 active and 37 treated Lyme neuroborreliosis patients, 28 healthy individuals treated for an early manifestation of LB in the past, and 145 untreated healthy individuals. The median numbers of B. burgdorferi B31-specific IFN-γ-secreting T cells/2.5 × 10 5 PBMCs did not differ between active Lyme neuroborreliosis patients (6.0; interquartile range [IQR], 0.5 to 14.0), treated Lyme neuroborreliosis patients (4.5; IQR, 2.0 to 18.6), and treated healthy individuals (7.4; IQR, 2.3 to 14.9) ( P = 1.000); however, the median number of B. burgdorferi B31-specific IFN-γ-secreting T cells/2.5 × 10 5 PBMCs among untreated healthy individuals was lower (2.0; IQR, 0.5 to 3.9) ( P ≤ 0.016). We conclude that the Borrelia ELISpot assay, measuring the number of B. burgdorferi B31-specific IFN-γ-secreting T cells/2.5 × 10 5 PBMCs, correlates with exposure to the Borrelia bacterium but cannot be used for the diagnosis of active Lyme neuroborreliosis. Copyright © 2018 van Gorkom et al.

  5. Identification of high-affinity anti-IL-1 α autoantibodies in normal human serum as an interfering substance in a sensitive enzyme-linked immunosorbent assay for IL-1 α

    International Nuclear Information System (INIS)

    Mae, N.; Liberato, D.J.; Chizzonite, R.; Satoh, H.

    1991-01-01

    A highly reproducible, sensitive, and specific sandwich enzyme-linked immunosorbent assay (ELISA) for recombinant human IL-1 α (rhIL-1 alpha) has been developed. Results from this ELISA have demonstrated that the concentration of rhIL-1 α added to normal human serum (NHS) decreased by 16.3% after 3 h and 24.9% after 6 h at room temperature. Molecular exclusion column chromatography with Sephacryl S-300 HR revealed that 125I-labeled IL-1 α added to normal human serum rapidly formed higher molecular weight complexes without indication of proteolytic degradation. The observed reduction in immunoreactivity was correlated with this protein complex formation and accounted for the apparent instability of rhIL-1 α in NHS. Immunoblot analysis indicated that the molecular weight of the binding protein was 150-160K, and the IL-1 α binding activity was removed and recovered from NHS by Protein-G affinity chromatography; indicating that the binding protein was IL-1 α-specific IgG. The binding of 125I-labeled IL-1 α to the serum binding proteins could be inhibited by unlabeled IL-1 alpha (IC50 = 7.4 x 10(-11) M) but not by unlabeled IL-1 β. Kinetic analysis with 125I-labeled IL-1 alpha revealed that the average binding affinity of these IL-1 α-specific IgGs was 4.7 x 10(10) M-1. These results suggest that these autoantibodies may interfere with the detection of IL-1 α in human serum by various assay systems and also could be a regulator of circulating IL-1 α

  6. Evaluation of a broad-ranging and convenient enzyme-linked immunosorbent assay using the lysate of infected cells with five serotypes of Orientia tsutsugamushi, a causative agent of scrub typhus.

    Science.gov (United States)

    Ogawa, Motohiko; Satoh, Masaaki; Saijo, Masayuki; Ando, Shuji

    2017-01-05

    Scrub typhus is a mite-borne rickettsiosis caused by infection of Orientia tsutsugamushi, which is endemic to several Asia-Pacific Rim countries, including Japan. Although micro-indirect immunofluorescent assay (micro-IFA) is the standard method for the serological diagnosis of scrub typhus, enzyme-linked immunosorbent assay (ELISA) is considered to be more objective, by providing digitized results as opposed to being subject to the judgment of the evaluator as in micro-IFA. Therefore, the aim of this study was to develop a broad-ranging ELISA using the five major prevalent serotypes of O. tsutsugamushi in Japan as the antigens. Furthermore, in contrast to previous studies that used purified microorganisms via ultracentrifugation, we directly used the infected cells, and evaluated the diagnostic accuracy of this simplified method to that of micro-IFA. Evaluation of paired patient sera against the five serotypes showed that the accuracy of ELISA relative to micro-IFA was 87.4 and 79.5% for immunoglobulin (Ig)M and IgG assays, respectively, at the optimized cut-off value. Further evaluation of patient sera against the expected serotype of the infecting strain showed that the accuracy of ELISA compared to micro-IFA increased to 100 and 97.4% in the IgM and IgG assays, respectively. This suggests that use of the five prevalent serotypes contributed to the increase of the accuracy of ELISA. When applying the criteria of serological diagnosis for paired sera samples to ELISA, all 19 patients were diagnosed as positive; a ≥4-fold elevation of the antibody titer was observed in 15 of 19 patients that were positive, and very high antibody titers were observed in both paired sera samples of the remaining four patients. In addition, all samples of healthy subjects and patients with other types of rickettsiosis were diagnosed as negative using these criteria. Our results suggest the excellent performance of the new broad-ranging and convenient ELISA, which appears to be

  7. Feasibility of using microbeads with holographic barcodes to track DNA specimens in the clinical molecular laboratory

    Directory of Open Access Journals (Sweden)

    Jason D. Merker

    2013-07-01

    Full Text Available We demonstrate the feasibility of using glass microbeads with a holographic barcode identifier to track DNA specimens in the molecular pathology laboratory. These beads can be added to peripheral blood specimens and are carried through automated DNA extraction protocols that use magnetic glass particles. We found that an adequate number of microbeads are consistently carried over during genomic DNA extraction to allow specimen identification, that the beads do not interfere with the performance of several different molecular assays, and that the beads and genomic DNA remain stable when stored together under regular storage conditions in the molecular pathology laboratory. The beads function as an internal, easily readable specimen barcode. This approach may be useful for identifying DNA specimens and reducing errors associated with molecular laboratory testing.

  8. Microbeads and Engineering Design in Chemistry: No Small Educational Investigation

    Science.gov (United States)

    Hoffman, Adam; Turner, Ken

    2015-01-01

    A multipart laboratory activity introducing microbeads was created to meet engineering and engineering design practices consistent with new Next Generation Science Standards (NGSS). Microbeads are a current topic of concern as they have been found to cause adverse impacts in both marine and freshwater systems resulting in multiple states proposing…

  9. Improved methods for urinary atrazine mercapturate analysis-Assessment of an enzyme-linked immunosorbent assay (ELISA) and a novel liquid chromatography-mass spectrometry (LC-MS) method utilizing online solid phase extraction (SPE)

    International Nuclear Information System (INIS)

    Koivunen, Marja E.; Dettmer, Katja; Vermeulen, Roel; Bakke, Berit; Gee, Shirley J.; Hammock, Bruce D.

    2006-01-01

    Elimination of interfering substances in urine by solid phase extraction (SPE) prior to analysis resulted in 10-fold improvement in the sensitivity of atrazine mercapturate (AM) enzyme-linked immunosorbent assay (ELISA) compared to previous reports. Of the two tested SPE systems, Oasis[reg] HLB and MCX, the mixed-mode MCX gave good recoveries (82%) of AM in spiked samples measured by ELISA, whereas the reverse-phase HLB phase was not compatible with the immunochemical method. At relatively high concentrations of urinary AM (>20 ng mL -1 ), sample dilution was effective enough for the elimination of interfering substances. The new liquid chromatography-mass spectrometry (LC-MS) method developed for AM utilizes online-SPE with Oasis[reg] HLB, column switching and a stable-isotope internal standard. The limit of quantification (0.05 ng mL -1 ) indicates improved sensitivity compared with most previously published LC-MS methods for AM. Validation of all three methods, LC-MS, ELISA + SPE and ELISA + dilution with spiked urine samples showed good correlation between the known and measured concentrations with R 2 values of 0.996, 0.957 and 0.961, respectively. When a set (n = 70 plus 12 blind duplicates) of urine samples from farmers exposed to atrazine was analyzed, there was a good agreement (R 2 = 0.917) between the log normalized data obtained by ELISA + SPE and LC-MS. High correlation among the data obtained by the two tested methods and the LC-MS method by the Center of Disease Control and Prevention (CDC), together with low variability among the blind duplicates, suggests that both methods reported here would be suitable for the analysis of urinary AM as a biomarker for human exposure of atrazine

  10. Erysipelothrix rhusiopathiae and Mycoplasma hyopneumoniae: the sensitivities of enzyme-linked immunosorbent assays for detecting vaccinated sows of unknown disease status using serum and colostrum, and the correlation of the results for sow serum, colostrum, and piglet serum.

    Science.gov (United States)

    Jenvey, Caitlin J; Reichel, Michael P; Cockcroft, Peter D

    2015-03-01

    Due to relatively high concentrations of immunoglobulins, colostrum has the potential to improve the sensitivity of diagnostic tests for diseases in pigs when compared with serum. It is possible that colostrum could improve the sensitivity of the antibody enzyme-linked immunosorbent assay (ELISA) compared with serum. Colostrum is also essential for piglets, providing protection against infections in the first few weeks and months of life. The sensitivity of 2 commercially available ELISAs, one for the detection of Erysipelothrix rhusiopathiae and the second for Mycoplasma hyopneumoniae antibodies, when used with sow colostrum in comparison with serum was investigated. The correlation of maternal E. rhusiopathiae- and M. hyopneumoniae-specific antibody levels with specific-antibody serum levels in the piglet was also determined. The sensitivity was defined as the proportion of vaccinated sows that were correctly identified as vaccinated at a given cutoff point. The true disease status of the sows with regard to the 2 infections was unknown. Blood and colostrum samples were collected from 20 sows, 10 primiparous and 10 multiparous, and blood samples were also collected from the piglets of each sow, 48-72 hr post-farrowing. The sensitivities of both ELISAs were significantly improved when using colostrum compared with serum. Sow serum and colostrum optical density (OD) values were significantly correlated. The mean sow OD values for serum for E. rhusiopathiae and M. hyopneumoniae and colostrum for E. rhusiopathiae were significantly correlated with piglet serum OD levels. If the improved sensitivity of colostrum can be demonstrated in infected animals, this will increase the ability of the test to identify infected animals using both individual and pooled colostrum. Testing serum and/or colostrum using ELISA can be useful predictors of piglet disease-specific OD values. © 2015 The Author(s).

  11. Enhanced immunoassay for porcine circovirus type 2 antibody using enzyme-loaded and quantum dots-embedded shell–core silica nanospheres based on enzyme-linked immunosorbent assay

    International Nuclear Information System (INIS)

    Wu, Long; Li, Xuepu; Shao, Kang; Ye, Shiyi; Liu, Chen; Zhang, Chenjun; Han, Heyou

    2015-01-01

    Boosting the detection sensitivity of enzyme-linked immunosorbent assay (ELISA) is significant to the early clinical diagnosis of various diseases. Here, we developed a versatile immunosensor using silica nanospheres as carriers for sensitive detection of porcine circovirus type 2 (PCV2) antibody. With HRP enzyme covalently immobilized on the silica nanospheres and CdSe nanocrystals embedded inside, these signal probes were successfully utilized in the sensitive detection of PCV2 antibody by ELISA, fluorometry and square-wave voltammetry (SWV). To further demonstrate the performance of the immunosensor, Human IgG (HIgG) was used as a model analyte. Since more HRP and CdSe QDs were loaded, 5-, 200- and 400-fold enhancements in amplified ELISA, fluorometry and voltammetry responses for HIgG could be achieved compared to conventional ELISA. The respective detection limits of theses methods for HIgG were 3.9, 0.1 and 0.05 ng mL −1 with a RSD below 5% for amplified ELISA, fluorescence and SWV measurements. Additionally, a 100-fold improvement was obtained in the detection sensitivity for PCV2 antibody immunoassay. The versatile immunosensor exhibits good sensitivity, stability and reproducibility, suggesting its potential applications in clinical diagnostics. - Highlights: • A versatile ELISA-based immunoassay for PCV2 antibody was developed. • Enzyme and CdSe QDs modified SiO 2 particles were used to improve sensitivity. • The simultaneous three ELISA-based techniques enhanced the detection reliability. • The biosensors strategy could provide a new avenue to ELISA-based sensors

  12. Enhanced immunoassay for porcine circovirus type 2 antibody using enzyme-loaded and quantum dots-embedded shell–core silica nanospheres based on enzyme-linked immunosorbent assay

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Long; Li, Xuepu; Shao, Kang; Ye, Shiyi; Liu, Chen; Zhang, Chenjun; Han, Heyou, E-mail: hyhan@mail.hzau.edu.cn

    2015-08-05

    Boosting the detection sensitivity of enzyme-linked immunosorbent assay (ELISA) is significant to the early clinical diagnosis of various diseases. Here, we developed a versatile immunosensor using silica nanospheres as carriers for sensitive detection of porcine circovirus type 2 (PCV2) antibody. With HRP enzyme covalently immobilized on the silica nanospheres and CdSe nanocrystals embedded inside, these signal probes were successfully utilized in the sensitive detection of PCV2 antibody by ELISA, fluorometry and square-wave voltammetry (SWV). To further demonstrate the performance of the immunosensor, Human IgG (HIgG) was used as a model analyte. Since more HRP and CdSe QDs were loaded, 5-, 200- and 400-fold enhancements in amplified ELISA, fluorometry and voltammetry responses for HIgG could be achieved compared to conventional ELISA. The respective detection limits of theses methods for HIgG were 3.9, 0.1 and 0.05 ng mL{sup −1} with a RSD below 5% for amplified ELISA, fluorescence and SWV measurements. Additionally, a 100-fold improvement was obtained in the detection sensitivity for PCV2 antibody immunoassay. The versatile immunosensor exhibits good sensitivity, stability and reproducibility, suggesting its potential applications in clinical diagnostics. - Highlights: • A versatile ELISA-based immunoassay for PCV2 antibody was developed. • Enzyme and CdSe QDs modified SiO{sub 2} particles were used to improve sensitivity. • The simultaneous three ELISA-based techniques enhanced the detection reliability. • The biosensors strategy could provide a new avenue to ELISA-based sensors.

  13. Relationship between presence of cows with milk positive for Mycobacterium avium subsp. paratuberculosis-specific antibody by enzyme-linked immunosorbent assay and viable M. avium subsp. paratuberculosis in dust in cattle barns.

    Science.gov (United States)

    Eisenberg, Susanne W F; Chuchaisangrat, Ruj; Nielen, Mirjam; Koets, Ad P

    2013-09-01

    Paratuberculosis, or Johne's disease, in cattle is caused by Mycobacterium avium subsp. paratuberculosis, which has recently been suspected to be transmitted through dust. This longitudinal study on eight commercial M. avium subsp. paratuberculosis-positive dairy farms studied the relationship between the number of cows with M. avium subsp. paratuberculosis antibody-positive milk and the presence of viable M. avium subsp. paratuberculosis in settled-dust samples, including their temporal relationship. Milk and dust samples were collected in parallel monthly for 2 years. M. avium subsp. paratuberculosis antibodies in milk were measured by enzyme-linked immunosorbent assay (ELISA) and used as a proxy for M. avium subsp. paratuberculosis shedding. Settled-dust samples were collected by using electrostatic dust collectors (EDCs) at six locations in housing for dairy cattle and young stock. The presence of viable M. avium subsp. paratuberculosis was identified by liquid culture and PCR. The results showed a positive relationship (odds ratio [OR], 1.2) between the number of cows with ELISA-positive milk and the odds of having positive EDCs in the same airspace as the adult dairy cattle. Moreover, the total number of lactating cows also showed an OR slightly above 1. This relationship remained the same for settled-dust samples collected up to 2 months before or after the time of milk sampling. The results suggest that removal of adult cows with milk positive for M. avium subsp. paratuberculosis-specific antibody by ELISA might result in a decrease in the presence of viable M. avium subsp. paratuberculosis in dust and therefore in the environment. However, this decrease is likely delayed by several weeks at least. In addition, the data support the notion that M. avium subsp. paratuberculosis exposure of young stock is reduced by separate housing.

  14. Binding and leakage of barium in alginate microbeads.

    Science.gov (United States)

    Mørch, Yrr A; Qi, Meirigeng; Gundersen, Per Ole M; Formo, Kjetil; Lacik, Igor; Skjåk-Braek, Gudmund; Oberholzer, Jose; Strand, Berit L

    2012-11-01

    Microbeads of alginate crosslinked with Ca(2+) and/or Ba(2+) are popular matrices in cell-based therapy. The aim of this study was to quantify the binding of barium in alginate microbeads and its leakage under in vitro and accumulation under in vivo conditions. Low concentrations of barium (1 mM) in combination with calcium (50 mM) and high concentrations of barium (20 mM) in gelling solutions were used for preparation of microbeads made of high-G and high-M alginates. High-G microbeads accumulated barium from gelling solution and contained higher concentrations of divalent ions for both low- and high-Ba exposure compared with high-G microbeads exposed to calcium solely and to high-M microbeads for all gelling conditions. Although most of the unbound divalent ions were removed during the wash and culture steps, leakage of barium was still detected during storage. Barium accumulation in blood and femur bone of mice implanted with high-G beads was found to be dose-dependent. Estimated barium leakage relevant to transplantation to diabetic patients with islets in alginate microbeads showed that the leakage was 2.5 times lower than the tolerable intake value given by WHO for high-G microbeads made using low barium concentration. The similar estimate gave 1.5 times higher than is the tolerable intake value for the high-G microbeads made using high barium concentration. To reduce the risk of barium accumulation that may be of safety concern, the microbeads made of high-G alginate gelled with a combination of calcium and low concentration of barium ions is recommended for islet transplantation. Copyright © 2012 Wiley Periodicals, Inc.

  15. Salmonella capture using orbiting magnetic microbeads

    Science.gov (United States)

    Owen, Drew; Ballard, Matthew; Mills, Zachary; Hanasoge, Srinivas; Hesketh, Peter; Alexeev, Alexander

    2014-11-01

    Using three-dimensional simulations and experiments, we examine capture of salmonella from a complex fluid sample flowing through a microfluidic channel. Capture is performed using orbiting magnetic microbeads, which can easily be extracted from the system for analysis after salmonella capture. Numerical simulations are used to model the dynamics of the system, which consists of a microchannel filled with a viscous fluid, model salmonella, magnetic microbeads and a series of angled parallel ridges lining the top of the microchannel. Simulations provide a statistical measure of the ability of the system to capture target salmonella. Our modeling findings guide the design of a lab-on-a-chip experimental device to be used for the detection of salmonella from complex food samples, allowing for the detection of the bacteria at the food source and preventing the consumption of contaminated food. Such a device can be used as a generic platform for the detection of a variety of biomaterials from complex fluids. This work is supported by a grant from the United States Department of Agriculture.

  16. Development and application of an enzyme-linked immunosorbent assay for specific detection of mangiferin content in various cultivars of Mangifera indica leaves using anti-mangiferin polyclonal antibody.

    Science.gov (United States)

    Yusakul, Gorawit; Kitirattrakarn, Wongsathorn; Tanwanichkul, Narunat; Tanaka, Hiroyuki; Putalun, Waraporn

    2012-04-01

    An enzyme-linked immunosorbent assay (ELISA) was developed for determining mangiferin content in plant samples using a polyclonal antibody (PAb) against mangiferin. The developed ELISA showed a full measurement range from 0.12 to 31.25 μg/mL mangiferin with a relative standard deviation (RSD) less than 6% for both intra- and interassay precision levels. The accuracy was determined by a percent recovery experiment at three concentration levels and it showed 97.8%-103.7% recovery in Mangifera indica leaf samples. The developed ELISA exhibited a high correlation value (R² = 0.992) with the standard high-performance liquid chromatography (HPLC) method in various mangiferin-containing plant samples. Our results suggest that the validated ELISA methodology using a PAb against mangiferin can be applied to determine mangiferin content with high specificity, rapidity and simplicity in various mangiferin-containing plant samples. The mangiferin content in the mature leaves of fifty M. indica cultivars were determined using the developed ELISA. The mangiferin contents ranged from 1.94 ± 0.13% to 13.79 ± 0.84% dry wt. The Thawai cultivar leaves contained the highest level of mangiferin (13.79 ± 0.84% dry wt), but it is a rare cultivar. The Namdokmai, which is more commonly cultivated in Thailand, contain 12.41 ± 0.60% dry wt mangiferin; therefore, this cultivar leaf was recommended as the source of raw material for the pharmaceutical, nutraceutical and cosmetic product industries. Currently, natural heath products are accepted worldwide for healthcare. Mangiferin-containing plants and products exhibit health benefits against oxidative stress-related diseases, such as cardiovascular diseases, cancer, dyslipidemia and diabetes. We have developed an ELISA with high specificity, rapidity and simplicity for the quality control of mangiferin-derived product production. Moreover, we found that the Namdokmai leaf, a Thai M. indica cultivar, was recommended as the source of raw

  17. Comparison of a novel chemiluminescence enzyme immunoassay (CLEIA) with enzyme-linked immunosorbent assay (ELISA) for the determination of MPO-ANCA in patients with ANCA-associated vasculitis.

    Science.gov (United States)

    Hirose, Orie; Itabashi, Mitsuyo; Takei, Takashi; Nitta, Kosaku

    2015-03-01

    Myeloperoxidase (MPO) anti-neutrophil cytoplasmic antibody (ANCA) represents the serological hallmark of ANCA-associated vasculitis (AAV). We evaluated the analytical and diagnostic accuracy of chemiluminescence enzyme immunoassay (CLEIA) versus enzyme-linked immunosorbent assay (ELISA) for the detection of MPO-ANCA. A total of 242 sera obtained from 51 patients with AAV and 103 patients without AAV were tested for MPO-ANCA by ELISA (NephroScholor MPOANC II) and CLEIA (the STACIA MEBLux test). Disease activity in the patients with AAV was determined based on the Birmingham Vasculitis Activity Score. We analyzed the correlations between the MPO-ANCA titers determined by the CLEIA and those determined by the ELISA, and also between the MPO-ANCA titers and the disease activity. The MPO-ANCA titers determined by the CLEIA (x) were strongly correlated with those determined by the ELISA (y). The correlation could be expressed by the following equation in this study: y = 1.8x + 7.7 (r = 0.96; p ELISA yielded positive test results in 57 of the 242 sera (23.6%). The CLEIA yielded false-positive test results in 4 of the 120 sera obtained from the non-AAV patients (3.3%), whereas the ELISA yielded a false-positive result in only 1 of the 120 sera obtained from the non-AAV patients (0.8%). The sensitivity and specificity of the CLEIA for the diagnosis of AAV were 100% and 96.7%, respectively, while those of the ELISA were 94.3% and 99.2%, respectively. The sensitivity and specificity of the CLEIA for the prediction of active disease were 100% and 64.4%, respectively, while those of the ELISA were 94.3% and 73.6%, respectively. The false positivity rate of the CLEIA for MPO-ANCA tended to be high as compared with that of the ELISA. Also, according to the correlation coefficient between the results of the CLEIA and the ELISA calculated in this study, it is necessary to pay attention to the differences in the sensitivity and specificity between CLEIA and ELISA.

  18. Development of Sustained-Release Microbeads of Nifedipine and In ...

    African Journals Online (AJOL)

    Methods: Nifedipine microbeads were prepared using sodium alginate and pectin in different ratios by ionic-gelation method. ... Oral sustained release dosage forms provide ... Stability in .... 37oC) in a USP XXII apparatus (Pharma Test,.

  19. (PCR) assays with enzyme-linked immunosorbent assay (ELISA)

    African Journals Online (AJOL)

    user

    2011-01-24

    Jan 24, 2011 ... Visceral leishmaniasis (VL) is systemic zoonotic parasitic infection that is a health problem in some tropical and subtropical countries. The purpose of our study is to determine the seroprevalence of canine visceral leishmaniasis (CVL) in owned dogs of the Sarab area and to identify the species of.

  20. False-Positive Results in a Recombinant Severe Acute Respiratory Syndrome-Associated Coronavirus (SARS-CoV) Nucleocapsid Enzyme-Linked Immunosorbent Assay Due to HCoV-OC43 and HCoV-229E Rectified by Western Blotting with Recombinant SARS-CoV Spike Polypeptide

    OpenAIRE

    Woo, Patrick C. Y.; Lau, Susanna K. P.; Wong, Beatrice H. L.; Chan, Kwok-Hung; Hui, Wai-Ting; Kwan, Grace S. W.; Peiris, J. S. Malik; Couch, Robert B.; Yuen, Kwok-Yung

    2004-01-01

    Using paired serum samples obtained from patients with illness associated with increases in anti-human coronavirus OC43 (HCoV-OC43) or anti-HCoV-229E antibodies, we examined the possibility of false-positive results detected in a recombinant severe acute respiratory syndrome (SARS)-associated coronavirus (SARS-CoV) nucleocapsid protein immunoglobulin G enzyme-linked immunosorbent assay (ELISA). Three of the 21 and 1 of the 7 convalescent-phase serum samples from persons with increases in anti...

  1. Diffusion and reaction in microbead agglomerates.

    Science.gov (United States)

    Nunes Kirchner, Carolina; Träuble, Markus; Wittstock, Gunther

    2010-04-01

    Scanning electrochemical microscopy has been used to analyze the flux of p-aminonophenol (PAP) produced by agglomerates of polymeric microbeads modified with galactosidase as a model system for the bead-based heterogeneous immunoassays. With the use of mixtures of enzyme-modified and bare beads in defined ratio, agglomerates with different saturation levels of the enzyme modification were produced. The PAP flux depends on the intrinsic kinetics of the galactosidase, the local availability of the substrate p-aminophenyl-beta-D-galactopyranoside (PAPG), and the external mass transport conditions in the surrounding of the agglomerate and the internal mass transport within the bead agglomerate. The internal mass transport is influenced by the diffusional shielding of the modified beads by unmodified beads. SECM in combination with optical microscopy was used to determine experimentally the external flux. These data are in quantitative agreement with boundary element simulation considering the SECM microelectrode as an interacting probe and treating the Michaelis-Menten kinetics of the enzyme as nonlinear boundary conditions with two independent concentration variables [PAP] and [PAPG]. The PAPG concentration at the surface of the bead agglomerate was taken as a boundary condition for the analysis of the internal mass transport condition as a function of the enzyme saturation in the bead agglomerate. The results of this analysis are represented as PAP flux per contributing modified bead and the flux from freely suspended galactosidase-modified beads. These numbers are compared to the same number from the SECM experiments. It is shown that depending on the enzyme saturation level a different situation can arise where either beads located at the outer surface of the agglomerate dominate the contribution to the measured external flux or where the contribution of buried beads cannot be neglected for explaining the measured external flux.

  2. Polymerase chain reaction versus enzyme-linked immunosorbent ...

    African Journals Online (AJOL)

    Polymerase chain reaction versus enzyme-linked immunosorbent assay in detection of Chlamydia trachomatis infection among gynaecological patients in southwestern Nigeria. ... Socio-demographic bio-data and gynaecological history were obtained with questionnaire; data was analyzed using SPSS version 20.0.

  3. Human embryonic stem cell-encapsulation in alginate microbeads in macroporous calcium phosphate cement for bone tissue engineering

    Science.gov (United States)

    Tang, Minghui; Chen, Wenchuan; Weir, Michael D.; Thein-Han, Wahwah; Xu, Hockin H. K.

    2012-01-01

    Human embryonic stem cells (hESCs) are exciting for regenerative medicine applications because of their strong proliferative ability and multilineage differentiation capability. To date there has been no report on hESC seeding with calcium phosphate cement (CPC). The objective of this study was to investigate hESC-derived mesenchymal stem cell (hESCd-MSC) encapsulation in hydrogel microbeads in macroporous CPC for bone tissue engineering. hESCs were cultured to form embryoid bodies (EBs), and the MSCs were then migrated out of the EBs. hESCd-MSCs had surface markers characteristic of MSCs, with positive alkaline phosphatase (ALP) staining when cultured in osteogenic medium. hESCd-MSCs were encapsulated in alginate at a density of 1 million cells/mL, with an average microbead size of 207 µm. CPC contained mannitol porogen to create a porosity of 64% and macropores with size of 218 µm, with 20% absorbable fibers for additional porosity when the fibers degrade. hESCd-MSCs encapsulated in microbeads in CPC had good viability from 1 to 21 d. ALP gene expression at 21 d was 25-fold that at 1 d. Osteocalcin (OC) at 21 d was two orders of magnitude of that at 1 d. ALP activity in colorimetric p-nitrophenyl phosphate assay at 21 d was 5-fold that at 1 d. Mineral synthesis by the encapsulated hESCd-MSCs at 21 d was 7-fold that at 1 d. Potential benefits of the CPC-stem cell paste include injectability, intimate adaptation to complex-shaped bone defects, ease in contouring to achieve esthetics in maxillofacial repairs, and in situ setting ability. In conclusion, hESCd-MSCs were encapsulated in alginate microbeads in macroporous CPC showing good cell viability, osteogenic differentiation and mineral synthesis for the first time. The hESCd-MSC-encapsulating macroporous CPC construct is promising for bone regeneration in a wide range of orthopedic and maxillofacial applications. PMID:22633970

  4. Treating inertia in passive microbead rheology.

    Science.gov (United States)

    Indei, Tsutomu; Schieber, Jay D; Córdoba, Andrés; Pilyugina, Ekaterina

    2012-02-01

    The dynamic modulus G(*) of a viscoelastic medium is often measured by following the trajectory of a small bead subject to Brownian motion in a method called "passive microbead rheology." This equivalence between the positional autocorrelation function of the tracer bead and G(*) is assumed via the generalized Stokes-Einstein relation (GSER). However, inertia of both bead and medium are neglected in the GSER so that the analysis based on the GSER is not valid at high frequency where inertia is important. In this paper we show how to treat both contributions to inertia properly in one-bead passive microrheological analysis. A Maxwell fluid is studied as the simplest example of a viscoelastic fluid to resolve some apparent paradoxes of eliminating inertia. In the original GSER, the mean-square displacement (MSD) of the tracer bead does not satisfy the correct initial condition. If bead inertia is considered, the proper initial condition is realized, thereby indicating an importance of including inertia, but the MSD oscillates at a time regime smaller than the relaxation time of the fluid. This behavior is rather different from the original result of the GSER and what is observed. What is more, the discrepancy from the GSER result becomes worse with decreasing bead mass, and there is an anomalous gap between the MSD derived by naïvely taking the zero-mass limit in the equation of motion and the MSD for finite bead mass as indicated by McKinley et al. [J. Rheol. 53, 1487 (2009)]. In this paper we show what is necessary to take the zero-mass limit of the bead safely and correctly without causing either the inertial oscillation or the anomalous gap, while obtaining the proper initial condition. The presence of a very small purely viscous element can be used to eliminate bead inertia safely once included in the GSER. We also show that if the medium contains relaxation times outside the window where the single-mode Maxwell behavior is observed, the oscillation can be

  5. Microfluidic production of bioactive fibrin micro-beads embedded in crosslinked collagen used as an injectable bulking agent for urinary incontinence treatment.

    Science.gov (United States)

    Vardar, E; Larsson, H M; Allazetta, S; Engelhardt, E M; Pinnagoda, K; Vythilingam, G; Hubbell, J A; Lutolf, M P; Frey, P

    2018-02-01

    Endoscopic injection of bulking agents has been widely used to treat urinary incontinence, often due to urethral sphincter complex insufficiency. The aim of the study was to develop a novel injectable bioactive collagen-fibrin bulking agent restoring long-term continence by functional muscle tissue regeneration. Fibrin micro-beads were engineered using a droplet microfluidic system. They had an average diameter of 140 μm and recombinant fibrin-binding insulin-like growth factor-1 (α 2 PI 1-8 -MMP-IGF-1) was covalently conjugated to the beads. A plasmin fibrin degradation assay showed that 72.5% of the initial amount of α 2 PI 1-8 -MMP-IGF-1 loaded into the micro-beads was retained within the fibrin micro-beads. In vitro, the growth factor modified fibrin micro-beads enhanced cell attachment and the migration of human urinary tract smooth muscle cells, however, no change of the cellular metabolic activity was seen. These bioactive micro-beads were mixed with genipin-crosslinked homogenized collagen, acting as a carrier. The collagen concentration, the degree of crosslinking, and the mechanical behavior of this bioactive collagen-fibrin injectable were comparable to reference samples. This novel injectable showed no burst release of the growth factor, had a positive effect on cell behavior and may therefore induce smooth muscle regeneration in vivo, necessary for the functional treatment of stress and other urinary incontinences. Urinary incontinence is involuntary urine leakage, resulting from a deficient function of the sphincter muscle complex. Yet there is no functional cure for this devastating condition using current treatment options. Applied physical and surgical therapies have limited success. In this study, a novel bioactive injectable bulking agent, triggering new muscle regeneration at the injection site, has been evaluated. This injectable consists of cross-linked collagen and fibrin micro-beads, functionalized with bound insulin-like growth factor

  6. Direct Comparison of the Histidine-rich Protein-2 Enzyme-linked Immunosorbent Assay (HRP-2 ELISA) and Malaria SYBR Green I Fluorescence (MSF) Drug Sensitivity Tests in Plasmodium falciparum Reference Clones and Fresh ex vivo Field Isolates from Cambodia

    Science.gov (United States)

    2013-07-12

    assessment of antimalarial activity in vitro by a semiautomated microdilution technique. Antimicrob Agents Chemother 1979, 16:710–718. 3. Noedl H, Attlmayr B...40:685–691. 32. Hawley SR, Bray PG, Mungthin M, Atkinson JD, O’Neill PM, Ward SA: Relationship between antimalarial drug activity , accumulation, and...success rate when testing DHA, AS, MQ, QN, CQ, and PPQ activities . A “successful” IC50 assay result for each P. falciparum clinical isolate was defined as

  7. Characterisation of plastic microbeads in facial scrubs and their estimated emissions in Mainland China.

    Science.gov (United States)

    Cheung, Pui Kwan; Fok, Lincoln

    2017-10-01

    Plastic microbeads are often added to personal care and cosmetic products (PCCPs) as an abrasive agent in exfoliants. These beads have been reported to contaminate the aquatic environment and are sufficiently small to be readily ingested by aquatic organisms. Plastic microbeads can be directly released into the aquatic environment with domestic sewage if no sewage treatment is provided, and they can also escape from wastewater treatment plants (WWTPs) because of incomplete removal. However, the emissions of microbeads from these two sources have never been estimated for China, and no regulation has been imposed on the use of plastic microbeads in PCCPs. Therefore, in this study, we aimed to estimate the annual microbead emissions in Mainland China from both direct emissions and WWTP emissions. Nine facial scrubs were purchased, and the microbeads in the scrubs were extracted and enumerated. The microbead density in those products ranged from 5219 to 50,391 particles/g, with an average of 20,860 particles/g. Direct emissions arising from the use of facial scrubs were estimated using this average density number, population data, facial scrub usage rate, sewage treatment rate, and a few conservative assumptions. WWTP emissions were calculated by multiplying the annual treated sewage volume and estimated microbead density in treated sewage. We estimated that, on average, 209.7 trillion microbeads (306.9 tonnes) are emitted into the aquatic environment in Mainland China every year. More than 80% of the emissions originate from incomplete removal in WWTPs, and the remaining 20% are derived from direct emissions. Although the weight of the emitted microbeads only accounts for approximately 0.03% of the plastic waste input into the ocean from China, the number of microbeads emitted far exceeds the previous estimate of plastic debris (>330 μm) on the world's sea surface. Immediate actions are required to prevent plastic microbeads from entering the aquatic environment

  8. Fractal dimension of microbead assemblies used for protein detection.

    Science.gov (United States)

    Hecht, Ariel; Commiskey, Patrick; Lazaridis, Filippos; Argyrakis, Panos; Kopelman, Raoul

    2014-11-10

    We use fractal analysis to calculate the protein concentration in a rotating magnetic assembly of microbeads of size 1 μm, which has optimized parameters of sedimentation, binding sites and magnetic volume. We utilize the original Forrest-Witten method, but due to the relatively small number of bead particles, which is of the order of 500, we use a large number of origins and also a large number of algorithm iterations. We find a value of the fractal dimension in the range 1.70-1.90, as a function of the thrombin concentration, which plays the role of binding the microbeads together. This is in good agreement with previous results from magnetorotation studies. The calculation of the fractal dimension using multiple points of reference can be used for any assembly with a relatively small number of particles. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Soft chitosan microbeads scaffold for 3D functional neuronal networks.

    Science.gov (United States)

    Tedesco, Maria Teresa; Di Lisa, Donatella; Massobrio, Paolo; Colistra, Nicolò; Pesce, Mattia; Catelani, Tiziano; Dellacasa, Elena; Raiteri, Roberto; Martinoia, Sergio; Pastorino, Laura

    2018-02-01

    The availability of 3D biomimetic in vitro neuronal networks of mammalian neurons represents a pivotal step for the development of brain-on-a-chip experimental models to study neuronal (dys)functions and particularly neuronal connectivity. The use of hydrogel-based scaffolds for 3D cell cultures has been extensively studied in the last years. However, limited work on biomimetic 3D neuronal cultures has been carried out to date. In this respect, here we investigated the use of a widely popular polysaccharide, chitosan (CHI), for the fabrication of a microbead based 3D scaffold to be coupled to primary neuronal cells. CHI microbeads were characterized by optical and atomic force microscopies. The cell/scaffold interaction was deeply characterized by transmission electron microscopy and by immunocytochemistry using confocal microscopy. Finally, a preliminary electrophysiological characterization by micro-electrode arrays was carried out. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Single-step laser-based fabrication and patterning of cell-encapsulated alginate microbeads

    International Nuclear Information System (INIS)

    Kingsley, D M; Dias, A D; Corr, D T; Chrisey, D B

    2013-01-01

    Alginate can be used to encapsulate mammalian cells and for the slow release of small molecules. Packaging alginate as microbead structures allows customizable delivery for tissue engineering, drug release, or contrast agents for imaging. However, state-of-the-art microbead fabrication has a limited range in achievable bead sizes, and poor control over bead placement, which may be desired to localize cellular signaling or delivery. Herein, we present a novel, laser-based method for single-step fabrication and precise planar placement of alginate microbeads. Our results show that bead size is controllable within 8%, and fabricated microbeads can remain immobilized within 2% of their target placement. Demonstration of this technique using human breast cancer cells shows that cells encapsulated within these microbeads survive at a rate of 89.6%, decreasing to 84.3% after five days in culture. Infusing rhodamine dye into microbeads prior to fluorescent microscopy shows their 3D spheroidal geometry and the ability to sequester small molecules. Microbead fabrication and patterning is compatible with conventional cellular transfer and patterning by laser direct-write, allowing location-based cellular studies. While this method can also be used to fabricate microbeads en masse for collection, the greatest value to tissue engineering and drug delivery studies and applications lies in the pattern registry of printed microbeads. (paper)

  11. Whey microbeads as a matrix for the encapsulation and immobilisation of riboflavin and peptides.

    Science.gov (United States)

    O'Neill, Graham J; Egan, Thelma; Jacquier, Jean Christophe; O'Sullivan, Michael; Dolores O'Riordan, E

    2014-10-01

    Whey microbeads manufactured using a cold-set gelation process, have been used to encapsulate bioactives. In this study whey microbeads were used to encapsulate riboflavin using 2 methods. Riboflavin was added to the microbead forming solution however diffusional losses of riboflavin occurred during the subsequent bead preparation. To overcome riboflavin loss, a second approach to 'load' whey microbeads by soaking in riboflavin was assessed. Significantly (p⩽0.05) higher concentrations of riboflavin were obtained in 'loaded' microbeads (361 mg/L) compared to riboflavin added to the microbead forming solution (48 mg/L). Riboflavin uptake by the microbeads was shown to be via a partition process. As partitioning is often driven by hydrophobic interactions the uptake of amino acids and peptides of varying hydrophobicities by the microbeads was examined. The % encapsulation increased with increasing molecule hydrophobicity with a maximum of 89% encapsulation. Whey microbeads are well suited to act as sorbents for encapsulation. Copyright © 2014 Elsevier Ltd. All rights reserved.

  12. DNA & Protein detection based on microbead agglutination

    KAUST Repository

    Kodzius, Rimantas; Castro, David; Foulds, Ian G.; Parameswaran, Ash M.; Sumanpreet, K. Chhina

    2012-01-01

    the macroscopic observation. Agglutination-based tests are most often used to explore the antibody-antigen reactions. Agglutination has been used for mode protein assays using a biotin/streptavidin two-component system, as well as a hybridization based two

  13. Quantum-dots-encoded-microbeads based molecularly imprinted polymer.

    Science.gov (United States)

    Liu, Yixi; Liu, Le; He, Yonghong; He, Qinghua; Ma, Hui

    2016-03-15

    Quantum dots encoded microbeads have various advantages such as large surface area, superb optical properties and the ability of multiplexing. Molecularly imprinted polymer that can mimic the natural recognition entities has high affinity and selectivity for the specific analyte. Here, the concept of utilizing the quantum dots encoded microbeads as the supporting material and the polydopamine as the functional monomer to form the core-shell molecular imprinted polymer was proposed for the first time. The resulted imprinted polymer can provide various merits: polymerization can complete in aqueous environment; fabrication procedure is facile and universal; the obvious economic advantage; the thickness of the imprinting layer is highly controllable; polydopamine coating can improve the biocompatibility of the quantum dot encoded microbeads. The rabbit IgG binding and flow cytometer experiment result showed the distinct advantages of this strategy: cost-saving, facile and fast preparation procedure. Most importantly, the ability for the multichannel detection, which makes the imprinted polydopamine modified encoded-beads very attractive in protein pre-concentration, recognition, separation and biosensing. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Fabrication and Evaluation of Tinidazole Microbeads for Colon Targeting

    Directory of Open Access Journals (Sweden)

    Amit K. Pandey

    2012-05-01

    Full Text Available Objective: The purpose of present investigation was to develop and evaluate multiparticulate system exploiting pH-sensitive property and specific biodegradability of calcium alginate microbeads, for colon- targeted delivery of Tinidazole for the treatment of amoebic colitis. Methods: Calcium alginate beads containing Tinidazole were prepared by ionotropic gelation technique followed by coating with Eudragit S100 using solvent evaporation method to obtain pH sensitive microbeads. Various formulation parameters were optimized which included concentration of sodium alginate (2% w/v, curing time (20 min and concentration of pectin (1% w/ v. All the formulations were evaluated for surface morphology, particle size analysis, entrapment efficiency and in-vitro drug release in conditions simulating colonic fluid in the presence of rat caecal (2% w/v content. Results: The average size of beads of optimized formulation (FT4 was found to be 998.73依5.12 毺 m with entrapment efficiency of 87.28依2.19 %. The invitro release of Eudragit S100 coated beads in presence of rat caecal content was found to be 70.73%依1.91% in 24 hours. Data of in-vitro release was fitted into Higuchi kinetics and Korsmeyer Peppas equation to explain release profile. The optimized formulation (FT4 showed zero order release. Conclusions: It is concluded that calcium alginate microbeads are the potential system for colon delivery of Tinidazole for chemotherapy of amoebic infection.

  15. Comparison of in-house biotin-avidin tetanus IgG enzyme-linked-immunosorbent assay (ELISA) with gold standard in vivo mouse neutralization test for the detection of low level antibodies.

    Science.gov (United States)

    Sonmez, Cemile; Coplu, Nilay; Gozalan, Aysegul; Akin, Lutfu; Esen, Berrin

    2017-06-01

    Detection of anti-tetanus antibody levels is necessary for both determination of the immune status of individuals and also for planning preventive measures. ELISA is the preferred test among in vitro tests however it can be affected by the cross reacting antibodies. A previously developed in-house ELISA test was found not reliable for the antibody levels ≤1.0IU/ml. A new method was developed to detect low antibody levels correctly. The aim of the present study was to compare the results of the newly developed in-house biotin-avidin tetanus IgG ELISA test with the in vivo mouse neutralization test, for the antibody levels ≤1.0IU/ml. A total of 54 serum samples with the antibody levels of three different levels, =0.01IU/ml, 0.01-0.1IU/ml, 0.1-1IU/ml, which were detected by in vivo mouse neutralization test were studied by the newly developed in-house biotin-avidin tetanus IgG ELISA test. Test was validated by using five different concentrations (0.01IU/ml, 0.06IU/ml, 0.2IU/ml, 0.5IU/ml, 1.0IU/ml). A statistically significant correlation (r 2 =0.9967 p=0,001) between in vivo mouse neutralization test and in-house biotin-avidin tetanus IgG ELISA test, was observed. For the tested concentrations intra-assay, inter-assay, accuracy, sensitivity, specificity and coefficients of variations were determined as ≤15%. In-house biotin-avidin tetanus IgG ELISA test can be an alternative method to in vivo mouse neutralization method for the detection of levels ≤1.0IU/ml. By using in-house biotin-avidin tetanus IgG ELISA test, individuals with non protective levels, will be reliably detected. Copyright © 2017. Published by Elsevier B.V.

  16. A survey of 17α-ethinylestradiol and mestranol residues in Hawkesbury River, Australia, using a highly specific enzyme-linked immunosorbent assay (ELISA) demonstrates the levels of potential biological significance.

    Science.gov (United States)

    Uraipong, Chatchaporn; Allan, Robin D; Li, Chunhua; Kennedy, Ivan R; Wong, Victor; Lee, Nanju Alice

    2017-10-01

    This study reports on the potential status of 17α-ethinylestradiol (EE2) and mestranol (MeEE2) residues in aquatic environments in New South Wales (NSW), Australia, based on the analysis by a specific ELISA we developed. Polyclonal antibodies were raised against the EE2 hapten with a linker attached at the C3-position to direct the antibody binding towards the ring D of EE2/MeEE2. Using this approach, an ELISA highly specific to EE2 and MeEE2 was successfully developed, showing less than 3.1% cross-reactivity (% CR) with other major steroidal sex hormones and their derivatives. The assay performed with the limit of detection (LOD) of 0.04 ± 0.01µg/L for both EE2 and MeEE2, and the limit of quantitation (LOQ) of 0.05 ± 0.01ng/L when it was coupled with the SM2-Biobeads solid phase extraction. Prior to conducting the survey study, it was validated against the gas chromatography-mass spectrophotometry (GC-MS) method, which showed high correlation with R 2 of 0.934. Fresh surface water samples collected at different sites along Hawkesbury River in New South Wales (NSW) were analyzed for the EE2/ MeEE2 residues using the developed ELISA. The EE2/MeEE2 levels were found to range between 4.1 and 8.3ng/L in Emigrant Creek, NSW, where the primary activity was macadamia plantation, and higher levels between 15 and 29ng/L in South Creek, NSW, Greater Western Sydney at sites upstream and downstream of the municipal sewage treatment plants. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Optical sensing properties of Au nanoparticle/hydrogel composite microbeads using droplet microfluidics

    Science.gov (United States)

    Li, Huilin; Men, Dandan; Sun, Yiqiang; Zhang, Tao; Hang, Lifeng; Liu, Dilong; Li, Cuncheng; Cai, Weiping; Li, Yue

    2017-10-01

    Uniform Au nanoparticle (NP)/poly (acrylamide-co-acrylic acid) [P(AAm-co-AA)] hydrogel microbeads were successfully prepared using droplet microfluidics technology. The microbeads exhibited a good stimuli-responsive behavior to pH value. Particularly in the pH value ranging from pH 2-pH 9, the composite microbead sizes gradually increased along with the increase of pH value. The homogeneous Au NPs, which were encapsulated in the P(AAm-co-AA) hydrogel microbeads, could transform the volume changes of hydrogel into optical signals by a tested single microbead with a microspectrometre system. The glucose was translated into gluconic acid by glucose oxidase. Thus, the Au NP/P(AAm-co-AA) hydrogel microbeads were used for detecting glucose based on pH effects on the composite microbeads. For this, the single Au NP/P(AAm-co-AA) hydrogel microbead could act as a good pH- or glucose-visualizing sensor.

  18. Preparation and recognition of surface molecularly imprinted core-shell microbeads for protein in aqueous solutions

    International Nuclear Information System (INIS)

    Lu Yan; Yan Changling; Gao Shuyan

    2009-01-01

    In this paper, a surface molecular imprinting technique was reported for preparing core-shell microbeads of protein imprinting, and bovine hemoglobin or bovine serum albumin were used as model proteins for studying the imprinted core-shell microbeads. 3-Aminophenylboronic acid (APBA) was polymerized onto the surface of polystyrene microbead in the presence of the protein templates to create protein-imprinted core-shell microbeads. The various samples were characterized using scanning electron microscopy (SEM), transmission electron microscopy (TEM), Raman spectroscopy, X-ray photoelectron spectroscopy (XPS) and Brunauer-Emmett-Teller (BET) methods. The effect of pH on rebinding of the template hemoglobin, the specific binding and selective recognition were studied for the imprinted microbeads. The results show that the bovine hemoglobin-imprinted core-shell microbeads were successfully created. The shell was a sort of imprinted thin films with porous structure and larger surface areas. The imprinted microbeads have good selectivity for templates and high stability. Due to the recognition sites locating at or closing to the surface, these imprinted microbeads have good property of mass-transport. Unfortunately, the imprint technology was not successfully applied to imprinting bovine serum albumin (BSA).

  19. Preparation and recognition of surface molecularly imprinted core-shell microbeads for protein in aqueous solutions

    Energy Technology Data Exchange (ETDEWEB)

    Lu Yan, E-mail: yanlu2001@sohu.com [College of Chemistry and Environmental Science, Henan Normal University, 46 Jlanshe Road, Xinxiang 453007 (China); Yan Changling; Gao Shuyan [College of Chemistry and Environmental Science, Henan Normal University, 46 Jlanshe Road, Xinxiang 453007 (China)

    2009-04-01

    In this paper, a surface molecular imprinting technique was reported for preparing core-shell microbeads of protein imprinting, and bovine hemoglobin or bovine serum albumin were used as model proteins for studying the imprinted core-shell microbeads. 3-Aminophenylboronic acid (APBA) was polymerized onto the surface of polystyrene microbead in the presence of the protein templates to create protein-imprinted core-shell microbeads. The various samples were characterized using scanning electron microscopy (SEM), transmission electron microscopy (TEM), Raman spectroscopy, X-ray photoelectron spectroscopy (XPS) and Brunauer-Emmett-Teller (BET) methods. The effect of pH on rebinding of the template hemoglobin, the specific binding and selective recognition were studied for the imprinted microbeads. The results show that the bovine hemoglobin-imprinted core-shell microbeads were successfully created. The shell was a sort of imprinted thin films with porous structure and larger surface areas. The imprinted microbeads have good selectivity for templates and high stability. Due to the recognition sites locating at or closing to the surface, these imprinted microbeads have good property of mass-transport. Unfortunately, the imprint technology was not successfully applied to imprinting bovine serum albumin (BSA).

  20. Data mining strategies to improve multiplex microbead immunoassay tolerance in a mouse model of infectious diseases.

    Directory of Open Access Journals (Sweden)

    Akshay Mani

    Full Text Available Multiplex methodologies, especially those with high-throughput capabilities generate large volumes of data. Accumulation of such data (e.g., genomics, proteomics, metabolomics etc. is fast becoming more common and thus requires the development and implementation of effective data mining strategies designed for biological and clinical applications. Multiplex microbead immunoassay (MMIA, on xMAP or MagPix platform (Luminex, which is amenable to automation, offers a major advantage over conventional methods such as Western blot or ELISA, for increasing the efficiencies in serodiagnosis of infectious diseases. MMIA allows detection of antibodies and/or antigens efficiently for a wide range of infectious agents simultaneously in host blood samples, in one reaction vessel. In the process, MMIA generates large volumes of data. In this report we demonstrate the application of data mining tools on how the inherent large volume data can improve the assay tolerance (measured in terms of sensitivity and specificity by analysis of experimental data accumulated over a span of two years. The combination of prior knowledge with machine learning tools provides an efficient approach to improve the diagnostic power of the assay in a continuous basis. Furthermore, this study provides an in-depth knowledge base to study pathological trends of infectious agents in mouse colonies on a multivariate scale. Data mining techniques using serodetection of infections in mice, developed in this study, can be used as a general model for more complex applications in epidemiology and clinical translational research.

  1. Alginate-hydroxypropylcellulose hydrogel microbeads for alkaline phosphatase encapsulation.

    Science.gov (United States)

    Karewicz, A; Zasada, K; Bielska, D; Douglas, T E L; Jansen, J A; Leeuwenburgh, S C G; Nowakowska, M

    2014-01-01

    There is a growing interest in using proteins as therapeutics agents. Unfortunately, they suffer from limited stability and bioavailability. We aimed to develop a new delivery system for proteins. ALP, a model protein, was successfully encapsulated in the physically cross-linked sodium alginate/hydroxypropylcellulose (ALG-HPC) hydrogel microparticles. The obtained objects had regular, spherical shape and a diameter of ∼4 µm, as confirmed by optical microscopy and SEM analysis. The properties of the obtained microbeads could be controlled by temperature and additional coating or crosslinking procedures. The slow, sustained release of ALP in its active form with no initial burst effect was observed for chitosan-coated microspheres at pH = 7.4 and 37 °C. Activity of ALP released from ALG/HPC microspheres was confirmed by the occurance of effectively induced mineralization. SEM and AFM images revealed formation of the interpenetrated three-dimensional network of mineral, originating from the microbeads' surfaces. FTIR and XRD analyses confirmed formation of hydroxyapatite.

  2. Flexible mechanism of magnetic microbeads chains in an oscillating field

    Science.gov (United States)

    Li, Yan-Hom; Yen, Chia-Yen

    2018-05-01

    To investigate the use of magnetic microbeads for swimming at low Reynolds number, the flexible structure of microchains comprising superparamagnetic microbeads under the influence of oscillating magnetic fields is examined experimentally and theoretically. For a ductile chain, each particle has its own phase angle trajectory and phase-lag angle to the overall field. This present study thoroughly discusses the synchronicity of the local phase angle trajectory between each dyad of beads and the external field. The prominently asynchronous trajectories between the central and outer beads significantly dominate the flexible structure of the oscillating chain. In addition, the dimensionless local Mason number (Mnl) is derived as the solo controlling parameter to evaluate the structure of each dyad of beads in a flexible chain. The evolution of the local Mason number within an oscillating period implies the most unstable position locates near the center of the chain around 0.6P

  3. Laser direct-write of single microbeads into spatially-ordered patterns

    International Nuclear Information System (INIS)

    Phamduy, Theresa B; Schiele, Nathan R; Corr, David T; Chrisey, Douglas B; Raof, Nurazhani Abdul; Xie Yubing; Yan Zijie; Huang Yong

    2012-01-01

    Fabrication of heterogeneous microbead patterns on a bead-by-bead basis promotes new opportunities for sensors, lab-on-a-chip technology and cell-culturing systems within the context of customizable constructs. Laser direct-write (LDW) was utilized to target and deposit solid polystyrene and stem cell-laden alginate hydrogel beads into computer-programmed patterns. We successfully demonstrated single-bead printing resolution and fabricated spatially-ordered patterns of microbeads. The probability of successful microbead transfer from the ribbon surface increased from 0 to 80% with decreasing diameter of 600 to 45 µm, respectively. Direct-written microbeads retained spatial pattern registry, even after 10 min of ultrasonication treatment. SEM imaging confirmed immobilization of microbeads. Viability of cells encapsulated in transferred hydrogel microbeads achieved 37 ± 11% immediately after the transfer process, whereas randomly-patterned pipetted control beads achieved a viability of 51 ± 25%. Individual placement of >10 µm diameter microbeads onto planar surfaces has previously been unattainable. We have demonstrated LDW as a valuable tool for the patterning of single, micrometer-diameter beads into spatially-ordered patterns. (paper)

  4. Impact of polyethylene microbeads on the floating freshwater plant duckweed Lemna minor.

    Science.gov (United States)

    Kalčíková, Gabriela; Žgajnar Gotvajn, Andreja; Kladnik, Aleš; Jemec, Anita

    2017-11-01

    Microplastics (MP), small plastic particles below 5 mm, have become one of the central concerns of environmental risk assessment. Microplastics are continuously being released into the aquatic environment either directly through consumer products or indirectly through fragmentation of larger plastic materials. The aim of our study was to investigate the effect of polyethylene microbeads from cosmetic products on duckweed (Lemna minor), a freshwater floating plant. The effects of microbeads from two exfoliating products on the specific leaf growth rate, the chlorophyll a and b content in the leaves, root number, root length and root cell viability were assessed. At the same time, water leachates from microbeads were also prepared to exclude the contribution of cosmetic ingredients on the measured impacts. Specific leaf growth rate and content of photosynthetic pigments in duckweed leaves were not affected by polyethylene microbeads, but these microbeads significantly affected the root growth by mechanical blocking. Sharp particles also reduced the viability of root cells, while the impact of microbeads with a smooth surface was neglected. It was concluded that microbeads from cosmetic products can also have negative impacts on floating plants in freshwater ecosystems. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Clinical effectiveness and cost-effectiveness of use of therapeutic monitoring of tumour necrosis factor alpha (TNF-α) inhibitors [LISA-TRACKER® enzyme-linked immunosorbent assay (ELISA) kits, TNF-α-Blocker ELISA kits and Promonitor® ELISA kits] versus standard care in patients with Crohn's disease: systematic reviews and economic modelling.

    Science.gov (United States)

    Freeman, Karoline; Connock, Martin; Auguste, Peter; Taylor-Phillips, Sian; Mistry, Hema; Shyangdan, Deepson; Court, Rachel; Arasaradnam, Ramesh; Sutcliffe, Paul; Clarke, Aileen

    2016-11-01

    Systematic reviews and economic modelling of clinical effectiveness and cost-effectiveness of therapeutic monitoring of tumour necrosis factor alpha (TNF-α) inhibitors [using LISA-TRACKER ® enzyme-linked immunosorbent assay (ELISA) kits (Theradiag, Marne La Vallee, France, or Alpha Laboratories, Heriot, UK), TNF-α-Blocker ELISA kits (Immundiagnostik AG, Bensheim, Germany) and Promonitor ® ELISA kits (Proteomika, Progenika Biopharma, Bizkaia, Spain)] versus standard care for Crohn's disease (CD). Multiple electronic databases were searched from inception to December 2014 in order to identify primary studies and meta-analyses. Patients with moderate to severe active CD treated with infliximab (IFX) (Remicade ® , Merck Sharp & Dohme Ltd, Kenilworth, NJ, USA) or adalimumab (ADA) (Humira ® , AbbVie Inc., North Chicago, IL, USA). Monitoring of serum anti-TNF-α (IFX or ADA) and/or of anti-drug antibody levels using test assays with a test-treatment algorithm. Standard care. Any patient-related outcome, test agreement and cost-effectiveness estimates. The quality assessments used recognised checklists (Quality Assessment of Diagnostic Accuracy Studies-2, Cochrane, Philips and Consolidated Health Economic Evaluation Reporting Standards). Evidence was synthesised using narrative review and meta-analysis. A Markov model was built in TreeAge Pro 2013 (TreeAge Software, Inc., Williamstown, MA, USA). The model had a 4-week cycle and a 10-year time horizon, adopted a NHS and Personal Social Services perspective and used a linked evidence approach. Costs were adjusted to 2013/14 prices and discounted at 3.5%. We included 68 out of 2434 and 4 out of 2466 studies for the clinical effectiveness and cost-effectiveness reviews, respectively. Twenty-three studies comparing test methods were identified. Evidence on test concordance was sparse and contradictory, offering scant data for a linked evidence approach. Three studies [two randomised controlled trials (RCTs) and one

  6. Upconversion Nanoparticles-Encoded Hydrogel Microbeads-Based Multiplexed Protein Detection

    Science.gov (United States)

    Shikha, Swati; Zheng, Xiang; Zhang, Yong

    2018-06-01

    Fluorescently encoded microbeads are in demand for multiplexed applications in different fields. Compared to organic dye-based commercially available Luminex's xMAP technology, upconversion nanoparticles (UCNPs) are better alternatives due to their large anti-Stokes shift, photostability, nil background, and single wavelength excitation. Here, we developed a new multiplexed detection system using UCNPs for encoding poly(ethylene glycol) diacrylate (PEGDA) microbeads as well as for labeling reporter antibody. However, to prepare UCNPs-encoded microbeads, currently used swelling-based encapsulation leads to non-uniformity, which is undesirable for fluorescence-based multiplexing. Hence, we utilized droplet microfluidics to obtain encoded microbeads of uniform size, shape, and UCNPs distribution inside. Additionally, PEGDA microbeads lack functionality for probe antibodies conjugation on their surface. Methods to functionalize the surface of PEGDA microbeads (acrylic acid incorporation, polydopamine coating) reported thus far quench the fluorescence of UCNPs. Here, PEGDA microbeads surface was coated with silica followed by carboxyl modification without compromising the fluorescence intensity of UCNPs. In this study, droplet microfluidics-assisted UCNPs-encoded microbeads of uniform shape, size, and fluorescence were prepared. Multiple color codes were generated by mixing UCNPs emitting red and green colors at different ratios prior to encapsulation. UCNPs emitting blue color were used to label the reporter antibody. Probe antibodies were covalently immobilized on red UCNPs-encoded microbeads for specific capture of human serum albumin (HSA) as a model protein. The system was also demonstrated for multiplexed detection of both human C-reactive protein (hCRP) and HSA protein by immobilizing anti-hCRP antibodies on green UCNPs.

  7. and Indigenous Indirect Enzyme-Linked Immunosorbent Assay

    Directory of Open Access Journals (Sweden)

    Annapurna S. Agasthya

    2012-01-01

    Full Text Available Brucellosis is one of the most important reemerging zoonoses in many countries. Brucellosis is caused by Gram-negative coccobacillus belonging to genus Brucella. Human brucellosis often makes the diagnosis difficult. The symptoms and clinical signs most commonly reported are fever, fatigue, malaise, chills, sweats headaches, myalgia, arthralgia, and weight loss. Some cases have been presented with only joint pain, lower backache, and involuntary limb movement, burning feet, or ischemic heart attacks. The focus of this work was to develop a highly sensitive and specific indirect ELISA by using smooth lipopolysaccharide antigen of Brucella abortus 99 to detect anti-Brucella antibodies at Project Directorate on Animal Disease Monitoring and Surveillance. Serum samples collected from 652 individuals in whom fever was not the major symptom but the complaint was of joint pain, headache, lower backache, and so forth, were screened by Rose Bengal plate agglutination test (RBPT and standard tube agglutination test (STAT. Subsequent testing of sera by indigenous indirect ELISA detected 20 samples positive (3.6% seroprevalence, and indirect ELISA was found to be more sensitive than RBPT and STAT. The seroprevalence in South Karnataka was 2.14%, and in North Karnataka it was 0.92%.

  8. Competitive upconversion-linked immunosorbent assay for the\

    Czech Academy of Sciences Publication Activity Database

    Hlaváček, Antonín; Farka, Z.; Hübner, M.; Horňáková, V.; Němeček, D.; Niessner, R.; Skládal, P.; Knopp, D.; Gorris, H H.

    2016-01-01

    Roč. 88, č. 11 (2016), s. 6011-6017 ISSN 0003-2700 R&D Projects: GA ČR(CZ) GA14-28254S Institutional support: RVO:68081715 Keywords : photon-upconversion * diclofenac * immunoassay Subject RIV: CB - Analytical Chemistry , Separation Impact factor: 6.320, year: 2016

  9. Comparisons of competitive enzyme-linked immunosorbent assay ...

    African Journals Online (AJOL)

    Jane

    2011-07-18

    Jul 18, 2011 ... studies have shown that these genome seg-ments can vary in manner that reflects the geographical origin of the virus strains (Pritchard et al., 2004). Efficiency of PCR in diagnosis of BTV in several parts of the world, verified this technique as a rapid, reliable and sensitive diagnosis methods. The highly ...

  10. Competitive upconversion-linked immunosorbent assay for the\

    Czech Academy of Sciences Publication Activity Database

    Hlaváček, Antonín; Farka, Z.; Hübner, M.; Horňáková, V.; Němeček, D.; Niessner, R.; Skládal, P.; Knopp, D.; Gorris, H H.

    2016-01-01

    Roč. 88, č. 11 (2016), s. 6011-6017 ISSN 0003-2700 R&D Projects: GA ČR(CZ) GA14-28254S Institutional support: RVO:68081715 Keywords : photon-upconversion * diclofenac * immunoassay Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 6.320, year: 2016

  11. Comparisons of competitive enzyme-linked immunosorbent assay ...

    African Journals Online (AJOL)

    Bluetongue is a noncontagious, arthropod-borne viral disease of both domestic and wild ruminants. Bluetongue virus (BTV) is the type of species of the genus Orbivirus within the family Reoviridae. BTV is endemic in some areas with cattle and wild ruminants serving as reservoirs for the virus. Clinical symptoms are often ...

  12. Indirect Competitive Enzyme-Linked Immunosorbent Assay (ELISA).

    Science.gov (United States)

    Kohl, Thomas O; Ascoli, Carl A

    2017-07-05

    The indirect competitive ELISA (indirect cELISA) pits plate-immobilized antigen against antigens in solution for binding to antigen-specific antibody. The antigens in solution are in the test sample and are first incubated with antigen-specific antibody. These antibody-antigen complexes are then added to microtiter plates whose wells have been coated with purified antigen. The wells are washed to remove unbound antigen-antibody complexes and free antigen. A reporter-labeled secondary antibody is then added followed by the addition of substrate. Substrate hydrolysis yields a signal that is inversely proportional to antigen concentration within the sample. This is because when antigen concentration is high in the test sample, most of the antibody is bound before adding the solution to the plate. Most of the antibody remains in solution (as complexes) and is thus washed away before the addition of the reporter-labeled secondary antibody and substrate. Thus, the higher the antigen concentration in the test sample, the weaker the resultant signal in the detection step. The indirect cELISA is often used for competitive detection and quantification of antibodies against viral diseases in biological samples. © 2017 Cold Spring Harbor Laboratory Press.

  13. Evaluation of enzyme-linked immunosorbent and alternative assays for detection of HIV antibodies using panels of Brasilian sera Avaliação de testes sorológicos para a detecção de anticorpos anti-HIV em painéis de soros de brasileiros

    Directory of Open Access Journals (Sweden)

    Jairo Ivo-Dos-Santos

    1990-04-01

    Full Text Available Sera from 472 Brazilian subjects, confirmed to be either positive or negative for HIV antibodies and comprising the total clinical spectrum of HIV infection, were utilized in the evaluation of six commercially available enzyme-linked immunosorbent assays (ELISA, as well as of four alternative assays, namely indirect immunofluorescence (IIF, passive hemagglutination (PHA, dot blot and Karpas AIDS cell test. The sensitivities ranged from 100% (Abbott and Roche ELISA to 84.2% (PHA and the specificities ranged from 99.3% (IIF to 80.2% (PHA. The sensitivity and specificity of the PHA and the sensitivity of the Karpas cell test were significantly lower than those of the other tests. Although the IFF and dot blot had good sensitivities and specificities, the six ELISA were more attractive than those tests when other parameters such as ease of reading and duration of assay were considered.Os soros de 472 brasileiros, confirmados como sendo positivos ou negativos em relação à presença de anticorpos anti-HIV e compreendendo todo o espectro clínico da infecção, foram utilizados na avaliação de seis ensaios imunoenzimáticos comerciais (ELISA, bem como de quatro testes alternativos tais como imunofluorescência indireta (IFI, hemaglutinação passiva (HP, dot blot e Karpas AIDS cell test. As sensibilidades variaram de 100% (ELISA Abbott e Roche a 84,2% (HP e as especificidades variaram de 99,3% (IFI a 80,2% (HP. A sensibilidade e especificidade da HP e a sensibilidade do Karpas AIDS cell test foram significativamente menores que os outros ensaios. Embora a IFI e o dot blot tivessem apresentado uma boa sensibilidade e especificidade, os ensaios imunoenzimáticos (ELISA foram mais adequados para serem utilizados em triagem quando outros parâmetros tais como facilidade de leitura e interpretação dos resultados e duração dos ensaios foram considerados.

  14. An enzyme-linked immunosorbent assay for the detection of IgG antibodies against Babesia equi in horses Um ensaio imunoenzimático para a detecção de anticorpos IgG contra Babesia equi em eqüinos

    Directory of Open Access Journals (Sweden)

    Cristiane Divan Baldani

    2004-10-01

    Full Text Available A crude antigenic preparation of Babesia equi was used to develop and establish the suitability of an enzyme-linked immunosorbent assay (ELISA for the detection of parasite carriers. Optimal dilutions of the antigen, using positive and negative reference sera, were determined by checkboard titrations. The specificity and sensitivity of the ELISA were 100 %. A total of 90 serum samples were taken from horses from the Northeast region of São Paulo State and examined for diagnosis of equine B. equi infection by ELISA. Approximately 75% (n=67 of all the horses tested were found serologically positive for B. equi. These results suggest that the ELISA described may prove to be an appropriate serological test for epidemiological studies on B. equi infections in the field and that equine piroplasmosis is a cause for serious concern in the State of São Paulo, Brazil.Um ensaio de imunoadsorção enzimática (ELISA baseado em antígeno bruto de Babesia equi foi desenvolvido para a detecção de portadores crônicos de babesiose eqüina. As diluições ótimas do antígeno e dos soros controles positivo e negativo foram determinadas através de titulação em bloco. A sensibilidade e especificidade do teste foram de 100%. O ELISA foi empregado em 90 soros de eqüinos da região Nordeste do Estado de São Paulo, de modo que aproximadamente 75% (n=67 dos eqüinos foram positivos para B. equi. Estes resultados sugerem que o ELISA descrito pode ser utilizado no diagnóstico sorológico de B. equi e que a piroplasmose eqüina é um problema sério no Estado de São Paulo, Brasil.

  15. The fast release of stem cells from alginate-fibrin microbeads in injectable scaffolds for bone tissue engineering

    Science.gov (United States)

    Zhou, Hongzhi; Xu, Hockin H. K.

    2011-01-01

    Stem cell-encapsulating hydrogel microbeads of several hundred microns in size suitable for injection, that could quickly degrade to release the cells, are currently unavailable. The objectives of this study were to: (1) develop oxidized alginate-fibrin microbeads encapsulating human umbilical cord mesenchymal stem cells (hUCMSCs); (2) investigate microbead degradation, cell release, and osteogenic differentiation of the released cells for the first time. Three types of microbeads were fabricated to encapsulate hUCMSCs: (1) Alginate microbeads; (2) oxidized alginate microbeads; (3) oxidized alginate-fibrin microbeads. Microbeads with sizes of about 100–500 µm were fabricated with 1×106 hUCMSCs/mL of alginate. For the alginate group, there was little microbead degradation, with very few cells released at 21 d. For oxidized alginate, the microbeads started to slightly degrade at 14 d. In contrast, the oxidized alginate-fibrin microbeads started to degrade at 4 d and released the cells. At 7 d, the number of released cells greatly increased and showed a healthy polygonal morphology. At 21 d, the oxidized alginate-fibrin group had a live cell density that was 4-fold that of the oxidized alginate group, and 15-fold that of the alginate group. The released cells had osteodifferentiation, exhibiting highly elevated bone marker gene expressions of ALP, OC, collagen I, and Runx2. Alizarin staining confirmed the synthesis of bone minerals by hUCMSCs, with the mineral concentration at 21 d being 10-fold that at 7 d. In conclusion, fast-degradable alginate-fibrin microbeads with hUCMSC encapsulation were developed that could start to degrade and release the cells at 4 d. The released hUCMSCs had excellent proliferation, osteodifferentiation, and bone mineral synthesis. The alginate-fibrin microbeads are promising to deliver stem cells inside injectable scaffolds to promote tissue regeneration. PMID:21757229

  16. Kinetics of immobilisation and release of tryptophan, riboflavin and peptides from whey protein microbeads.

    Science.gov (United States)

    O'Neill, Graham J; Egan, Thelma; Jacquier, Jean Christophe; O'Sullivan, Michael; Dolores O'Riordan, E

    2015-08-01

    This study investigated the kinetics of immobilisation and release of riboflavin, amino acids and peptides from whey microbeads. Blank whey microbeads were placed in solutions of the compounds. As the volume of microbeads added to the solution was increased, the uptake of the compounds increased, to a maximum of 95% for the pentapeptide and 56%, 57% and 45% for the dipeptide, riboflavin and tryptophan respectively, however, the rate of uptake remained constant. The rate of uptake increased with increasing molecule hydrophobicity. The opposite was observed in the release studies, the more hydrophobic compounds had lower release rate constants (kr). When whey microbeads are used as sorbents, they show excellent potential to immobilise small hydrophobic molecules and minimise subsequent diffusion, even in high moisture environments. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Biocompatibility of hyaluronic acid hydrogels prepared by porous hyaluronic acid microbeads

    Science.gov (United States)

    Kim, Jin-Tae; Lee, Deuk Yong; Kim, Tae-Hyung; Song, Yo-Seung; Cho, Nam-Ihn

    2014-05-01

    Hyaluronic acid hydrogels (HAHs) were synthesized by immersing HA microbeads crosslinked with divinyl sulfone in a phosphate buffered saline solution to evaluate the biocompatibility of the gels by means of cytotoxicity, genotoxicity ( in vitro chromosome aberration test, reverse mutation assay, and in vivo micronucleus test), skin sensitization, and intradermal reactivity. The HAHs induced no cytotoxicity or genotoxicity. In guinea pigs treated with grafts and prostheses, no animals died and there were no abnormal clinical signs. The sensitization scores were zero in all guinea pigs after 24 h and 48 h challenge, suggesting that the HAHs had no contact allergic sensitization in the guinea pig maximization test. No abnormal signs were found in New Zealand White rabbits during the 72 h observation period after the injection. There was no difference between the HAHs and negative control mean scores because skin reaction such as erythema or oedema was not observed after injection. Experimental results suggest that the HAHs would be suitable for soft tissue augmentation due to the absence of cytotoxicity, genotoxicity, skin sensitization, and intradermal reactivity.

  18. In Vitro and In Vivo Biocompatibility Evaluation of Polyallylamine and Macromolecular Heparin Conjugates Modified Alginate Microbeads.

    Science.gov (United States)

    Vaithilingam, Vijayaganapathy; Steinkjer, Bjørg; Ryan, Liv; Larsson, Rolf; Tuch, Bernard Edward; Oberholzer, Jose; Rokstad, Anne Mari

    2017-09-15

    Host reactivity to biocompatible immunoisolation devices is a major challenge for cellular therapies, and a human screening model would be of great value. We designed new types of surface modified barium alginate microspheres, and evaluated their inflammatory properties using human whole blood, and the intraperitoneal response after three weeks in Wistar rats. Microspheres were modified using proprietary polyallylamine (PAV) and coupled with macromolecular heparin conjugates (Corline Heparin Conjugate, CHC). The PAV-CHC strategy resulted in uniform and stable coatings with increased anti-clot activity and low cytotoxicity. In human whole blood, PAV coating at high dose (100 µg/ml) induced elevated complement, leukocyte CD11b and inflammatory mediators, and in Wistar rats increased fibrotic overgrowth. Coating of high dose PAV with CHC significantly reduced these responses. Low dose PAV (10 µg/ml) ± CHC and unmodified alginate microbeads showed low responses. That the human whole blood inflammatory reactions paralleled the host response shows a link between inflammatory potential and initial fibrotic response. CHC possessed anti-inflammatory activity, but failed to improve overall biocompatibility. We conclude that the human whole blood assay is an efficient first-phase screening model for inflammation, and a guiding tool in development of new generation microspheres for cell encapsulation therapy.

  19. Application of upconversion luminescent-magnetic microbeads with weak background noise and facile separation in ochratoxin A detection

    Energy Technology Data Exchange (ETDEWEB)

    Liao, Zhenyu, E-mail: liaozy08@163.com [Tianjin Product Quality Inspection Technology Research Institute, The National Center of Supervision and Inspection for Quality of Food (China); Zhang, Ying [Tianjin University, School of Life Sciences, Tianjin Engineering Center of Micro-Nano Biomaterials and Detection-Treatment Technology (China); Su, Lin [Tianjin Medical University Eye Hospital, Eye Institute and School of Optometry and Ophthalmology (China); Chang, Jin; Wang, Hanjie, E-mail: wanghj@tju.edu.cn [Tianjin University, School of Life Sciences, Tianjin Engineering Center of Micro-Nano Biomaterials and Detection-Treatment Technology (China)

    2017-02-15

    Ochratoxin A (OTA), the most harmful and abundant ochratoxin, is chemically stable and commonly existed in foodstuffs. In this work, upconversion luminescent-magnetic microbeads (UCLMMs) -based cytometric bead array for OTA detection with a less reagent consumption and high sensitivity has been established and optimized. In UCLMMs, upconversion nanocrystals (UCNs) for optical code present a weak background noise and no spectral cross talk between the encoding signals and target labels under two excitation conditions to improve detection sensitivity. While the superparamagnetic Fe{sub 3}O{sub 4} nanoparticles (Fe{sub 3}O{sub 4} NPs) aim for rapid analysis. The results show that the developed method has a sensitivity of 9.553 ppt below HPLC with a 50-μL sample and can be completed in <2 h with good accuracy and high reproducibility. Therefore, different colors of UCLMMs will become a promising assay platform for multiple mycotoxins after further improvement.

  20. Application of upconversion luminescent-magnetic microbeads with weak background noise and facile separation in ochratoxin A detection

    International Nuclear Information System (INIS)

    Liao, Zhenyu; Zhang, Ying; Su, Lin; Chang, Jin; Wang, Hanjie

    2017-01-01

    Ochratoxin A (OTA), the most harmful and abundant ochratoxin, is chemically stable and commonly existed in foodstuffs. In this work, upconversion luminescent-magnetic microbeads (UCLMMs) -based cytometric bead array for OTA detection with a less reagent consumption and high sensitivity has been established and optimized. In UCLMMs, upconversion nanocrystals (UCNs) for optical code present a weak background noise and no spectral cross talk between the encoding signals and target labels under two excitation conditions to improve detection sensitivity. While the superparamagnetic Fe_3O_4 nanoparticles (Fe_3O_4 NPs) aim for rapid analysis. The results show that the developed method has a sensitivity of 9.553 ppt below HPLC with a 50-μL sample and can be completed in <2 h with good accuracy and high reproducibility. Therefore, different colors of UCLMMs will become a promising assay platform for multiple mycotoxins after further improvement.

  1. MUCOADHESIVE MICROBEADS OF METFORMIN HCL: A PROMISING SUSTAINED DRUG DELIVERY SYSTEM

    OpenAIRE

    B. Samyuktha Rani; Ambati Brahma Reddy; E. Lakshmi Sai; K. Lakshmi; M.Vasavi chandrika

    2012-01-01

    The present work was investigated to reduce the dosing frequency, improve patient compliance, to improve gastric residence and to decrease GI side effects by designing and evaluating controlled Release Mucoadhesive (CRM) microbeads of Metformin hydrochloride for effective control of diabetes type-II. Microbeads were prepared by employing ionic gelation method by using various natural and synthetic polymers such as sodium alginate as main polymer and sodium carboxy methyl cellulose(SCMC), carb...

  2. Monodisperse microbeads of hypercrosslinked polystyrene for liquid and supercritical fluid chromatography

    Science.gov (United States)

    Tsyurupa, M. P.; Blinnikova, Z. K.; Il'in, M. M.; Davankov, V. A.; Parenago, O. O.; Pokrovskii, O. I.; Usovich, O. I.

    2015-11-01

    Monodisperse styrene-divinylbenzene (1 wt %) copolymer microbeads are obtained via the elaborate method of high-productivity precipitation polymerization. The crosslinking of this copolymer with chloromethyl methyl ether in the presence of Friedel-Crafts catalyst yields porous hypercrosslinked polymers with degrees of crosslinking that range from 200 to 500%. Microbead sorbents are shown to be suited for selective stationary phases for high-performance liquid chromatography and supercritical fluid chromatography.

  3. Studies on preparing and adsorption property of grafting terpolymer microbeads of PEI-GMA/AM/MBA for bilirubin.

    Science.gov (United States)

    Gao, Baojiao; Lei, Haibo; Jiang, Liding; Zhu, Yong

    2007-06-15

    Crosslinking copolymer microbeads with a diameter range of 100-150 microm were synthesized by suspension copolymerization of glycidyl methacrylate (GMA), acrylamide (AM) and N,N'-methylene bisacrylamide (MBA). Subsequently, polyethyleneimine (PEI) was grafted on the surfaces of the terpolymer microbeads GMA/AM/MBA via the ring-opening reaction of the epoxy groups, and the grafting microbeads PEI-GMA/AM/MBA were prepared. In this paper, the adsorption property of the grafting microbeads for bilirubin was mainly investigated, and the effects of various factors, such as pH value, ionic strength and grafting degree of PEI on the surface of grafting microbeads and the adsorption capacity of the grafting microbeads for bilirubin were examined. The batch adsorption experiment results show that by right of the action of grafted polyamine macromolecules PEI, the grafting microbeads PEI-GMA/AM/MBA have quite strong adsorption ability for bilirubin; the isotherm adsorption conforms to Freundlich equation. The pH value of the medium affects the adsorption capacity greatly, As in the nearly neutral solutions with pH 6, the grafting microbeads have the strongest adsorption ability for bilirubin, whereas in acidic and basic solutions their adsorption ability is weak. The ionic strength hardly affects the adsorption ability of the grafting microbeads. The grafting degree of PEI on the surfaces of the grafting microbeads also has a great effect on the adsorption capacity, and higher the grafting degree of PEI on the surface of the microbead PEI-GMA/AM/MBA, the stronger is the adsorption ability of the microbeads.

  4. High-performance fluorescence-encoded magnetic microbeads as microfluidic protein chip supports for AFP detection

    Energy Technology Data Exchange (ETDEWEB)

    Gong, Xiaoqun [School of Life Sciences, Tianjin Engineering Center of Micro-Nano Biomaterials and Detection-Treatment Technology, Collaborative Innovation Center of Chemical Science and Engineering, Tianjin University, Tianjin 300072 (China); Yan, Huan; Yang, Jiumin [Department of Laboratory Medicine, Tianjin Medical University General Hospital, Tianjin, 300052 (China); Wu, Yudong; Zhang, Jian; Yao, Yingyi [School of Life Sciences, Tianjin Engineering Center of Micro-Nano Biomaterials and Detection-Treatment Technology, Collaborative Innovation Center of Chemical Science and Engineering, Tianjin University, Tianjin 300072 (China); Liu, Ping [Bioscience (Tianjin) Diagnostic Technology CO., LTD, Tianjin, 300300 (China); Wang, Huiquan [Department of Biomedical Engineering, School of Electronics and Information Engineering, Tianjin Polytechnic University, Tianjin, 300387 (China); Hu, Zhidong, E-mail: huzhidong27@163.com [Department of Laboratory Medicine, Tianjin Medical University General Hospital, Tianjin, 300052 (China); Chang, Jin, E-mail: jinchang@tju.edu.cn [School of Life Sciences, Tianjin Engineering Center of Micro-Nano Biomaterials and Detection-Treatment Technology, Collaborative Innovation Center of Chemical Science and Engineering, Tianjin University, Tianjin 300072 (China)

    2016-10-05

    Fluorescence-encoded magnetic microbeads (FEMMs), with the fluorescence encoding ability of quantum dots (QDs) and magnetic enrichment and separation functions of Fe{sub 3}O{sub 4} nanoparticles, have been widely used for multiple biomolecular detection as microfluidic protein chip supports. However, the preparation of FEMMs with long-term fluorescent encoding and immunodetection stability is still a challenge. In this work, we designed a novel high-temperature chemical swelling strategy. The QDs and Fe{sub 3}O{sub 4} nanoparticles were effectively packaged into microbeads via the thermal motion of the polymer chains and the hydrophobic interaction between the nanoparticles and microbeads. The FEMMs obtained a highly uniform fluorescent property and long-term encoding and immunodetection stability and could be quickly magnetically separated and enriched. Then, the QD-encoded magnetic microbeads were applied to alpha fetoprotein (AFP) detection via sandwich immunoreaction. The properties of the encoded microspheres were characterized using a self-designed detecting apparatus, and the target molecular concentration in the sample was also quantified. The results suggested that the high-performance FEMMs have great potential in the field of biomolecular detection. - Graphical abstract: We designed a novel strategy to prepare a kind of high-performance fluorescence-encoded magnetic microbeads as microfluidic protein chip support with long-time fluorescent encoding and immunodetection stability for AFP detection. - Highlights: • A novel strategy combined the high temperature with chemical swelling technology is designed. • Based on hydrophobic interaction and polymer thermal motion, QDs and Fe{sub 3}O{sub 4} were effectively packaged into microbeads. • The fluorescence-encoded magnetic microbeads show long-term fluorescent encoding and immunodetection stability.

  5. Ultra-high-throughput screening of an in vitro-synthesized horseradish peroxidase displayed on microbeads using cell sorter.

    Directory of Open Access Journals (Sweden)

    Bo Zhu

    Full Text Available The C1a isoenzyme of horseradish peroxidase (HRP is an industrially important heme-containing enzyme that utilizes hydrogen peroxide to oxidize a wide variety of inorganic and organic compounds for practical applications, including synthesis of fine chemicals, medical diagnostics, and bioremediation. To develop a ultra-high-throughput screening system for HRP, we successfully produced active HRP in an Escherichia coli cell-free protein synthesis system, by adding disulfide bond isomerase DsbC and optimizing the concentrations of hemin and calcium ions and the temperature. The biosynthesized HRP was fused with a single-chain Cro (scCro DNA-binding tag at its N-terminal and C-terminal sites. The addition of the scCro-tag at both ends increased the solubility of the protein. Next, HRP and its fusion proteins were successfully synthesized in a water droplet emulsion by using hexadecane as the oil phase and SunSoft No. 818SK as the surfactant. HRP fusion proteins were displayed on microbeads attached with double-stranded DNA (containing the scCro binding sequence via scCro-DNA interactions. The activities of the immobilized HRP fusion proteins were detected with a tyramide-based fluorogenic assay using flow cytometry. Moreover, a model microbead library containing wild type hrp (WT and inactive mutant (MUT genes was screened using fluorescence-activated cell-sorting, thus efficiently enriching the WT gene from the 1:100 (WT:MUT library. The technique described here could serve as a novel platform for the ultra-high-throughput discovery of more useful HRP mutants and other heme-containing peroxidases.

  6. Characterization and in vitro release studies of oral microbeads containing thiolated pectin–doxorubicin conjugates for colorectal cancer treatment

    Directory of Open Access Journals (Sweden)

    Kamonrak Cheewatanakornkool

    2017-11-01

    Full Text Available Novel oral microbeads were developed based on a biopolymer–drug conjugate of doxorubicin (DOX conjugated with thiolated pectin via reducible disulfide bonds. The microbeads were fabricated by ionotropic gelation with cations such as Al3+, Ca2+ and Zn2+. The results showed that using zinc acetate can produce the strongest microbeads with spherical shape. However, the microbeads prepared from thiolated pectin–DOX conjugate were very soft and irregular in shape. To produce more spherical microbeads with suitable strength, the native pectin was then added to the formulations. The particle size of the microbeads ranged from 0.87 to 1.14 mm. The morphology of the microbeads was characterized by optical and scanning electron microscopy. DOX was still in crystalline form when used in preparing the microbeads, as confirmed by powder X-ray diffractometry. Drug release profiles showed that the microbeads containing thiolated pectin–DOX conjugate exhibited reduction-responsive character; in reducing environments, the thiolated pectin–DOX conjugate could uncouple resulting from a cleavage of the disulfide linkers and consequently release the DOX. The best-fit release kinetics of the microbeads containing thiolated pectin–DOX conjugate, in the medium without reducing agent, fit the Korsmeyer–Peppas model while those in the medium with reducing agent fit a zero-order release model. These results suggested that the microbeads containing thiolated pectin–DOX conjugate may be a promising platform for cancer-targeted delivery of DOX, exploiting the reducing environment typically found in tumors.

  7. Protein imprinting and recognition via forming nanofilms on microbeads surfaces in aqueous media

    International Nuclear Information System (INIS)

    Lu Yan; Yan Changling; Wang Xuejing; Wang Gongke

    2009-01-01

    In this paler, we present a technique of forming nanofilms of poly-3-aminophenylboronic acid (pAPBA) on the surfaces of polystyrene (PS) microbeads for proteins (papain and trypsin) in aqueous. Papain was chosen as a model to study the feasibility of the technique and trypsin as an extension. Obtained core-shell microbeads were characterized using scanning electron microscopy (SEM), Raman spectroscopy, X-ray photoelectron spectroscopy (XPS) and BET methods. The results show that pAPBA formed nanofilms (60-100 nm in thickness) on the surfaces of PS microbeads. The specific surface area of the papain-imprinted beads was about 180 m 2 g -1 and its pore size was 31 nm. These imprinted microbeads exhibit high recognition specificity and fast mass transfer kinetics. The specificity of these imprinted beads mainly originates from the spatial effect of imprinted sites. Because the protein-imprinted sites were located at, or close to, the surface, the imprinted beads have good site accessibility toward the template molecules. The facility of the imprinting protocol and the high recognition properties of imprinted microbeads make the approach an attractive solution to problems in the field of biotechnology.

  8. Air plasma processing of poly(methyl methacrylate) micro-beads: Surface characterisations

    International Nuclear Information System (INIS)

    Liu Chaozong; Cui Naiyi; Osbeck, Susan; Liang He

    2012-01-01

    Highlights: ► PMMA micro-beads were processed using a rotary air plasma reactor. ► Surface chemistry and surface texture of PMMA micro-beads were characterised. ► Surface wettability was evaluated using “floating” water contact angle method. ► Surface oxidation and texture changes induced by air plasma attributed to the improvement of surface wettability. - Abstract: This paper reports the surface processing of poly(methyl methacrylate) (PMMA) micro-beads by using a rotary air plasma reactor, and its effects on surface properties. The surface properties, including surface wettability, surface chemistry and textures of the PMMA beads, were characterised. It was observed that the air plasma processing can improve the surface wettability of the PMMA microbeads significantly. A 15 min plasma processing can reduce the surface water contact angle of PMMA beads to about 50° from its original value of 80.3°. This was accompanied by about 8% increase in surface oxygen concentration as confirmed by XPS analysis. The optical profilometry examination revealed the air plasma processing resulted in a rougher surface that has a “delicate” surface texture. It is concluded that the surface chemistry and texture, induced by air plasma processing, co-contributed to the surface wettability improvement of PMMA micro-beads.

  9. International policies to reduce plastic marine pollution from single-use plastics (plastic bags and microbeads): A review.

    Science.gov (United States)

    Xanthos, Dirk; Walker, Tony R

    2017-05-15

    Marine plastic pollution has been a growing concern for decades. Single-use plastics (plastic bags and microbeads) are a significant source of this pollution. Although research outlining environmental, social, and economic impacts of marine plastic pollution is growing, few studies have examined policy and legislative tools to reduce plastic pollution, particularly single-use plastics (plastic bags and microbeads). This paper reviews current international market-based strategies and policies to reduce plastic bags and microbeads. While policies to reduce microbeads began in 2014, interventions for plastic bags began much earlier in 1991. However, few studies have documented or measured the effectiveness of these reduction strategies. Recommendations to further reduce single-use plastic marine pollution include: (i) research to evaluate effectiveness of bans and levies to ensure policies are having positive impacts on marine environments; and (ii) education and outreach to reduce consumption of plastic bags and microbeads at source. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Hyper alginate gel microbead formation by molecular diffusion at the hydrogel/droplet interface.

    Science.gov (United States)

    Hirama, Hirotada; Kambe, Taisuke; Aketagawa, Kyouhei; Ota, Taku; Moriguchi, Hiroyuki; Torii, Toru

    2013-01-15

    We report a simple method for forming monodispersed, uniformly shaped gel microbeads with precisely controlled sizes. The basis of our method is the placement of monodispersed sodium alginate droplets, formed by a microfluidic device, on an agarose slab gel containing a high-osmotic-pressure gelation agent (CaCl(2) aq.): (1) the droplets are cross-linked (gelated) due to the diffusion of the gelation agent from the agarose slab gel to the sodium alginate droplets and (2) the droplets simultaneously shrink to a fraction of their original size (slab gel. We verified the mass transfer mechanism between the droplet and the agarose slab gel. This method circumvents the limitations of gel microbead formation, such as the need to prepare microchannels of various sizes, microchannel clogging, and the deformation of the produced gel microbeads.

  11. Wastewater treatment plant effluents as source of cosmetic polyethylene microbeads to freshwater.

    Science.gov (United States)

    Kalčíková, G; Alič, B; Skalar, T; Bundschuh, M; Gotvajn, A Žgajnar

    2017-12-01

    Microplastics in the environment are either a product of the fractionation of larger plastic items or a consequence of the release of microbeads, which are ingredients of cosmetics, through wastewater treatment plant (WWTP) effluents. The aim of this study was to estimate the amount of microbeads that may be released by the latter pathways to surface waters using Ljubljana, Slovenia as a case study. For this purpose, microbeads contained in cosmetics were in a first step characterized for their physical properties and particle size distribution. Subsequently, daily emission of microbeads from consumers to the sewerage system, their fate in biological WWTPs and finally their release into surface waters were estimated for Ljubljana. Most of the particles found in cosmetic products were sewerage system at an average rate of 15.2 mg per person per day. Experiments using a lab-scale sequencing batch biological WWTP confirmed that on average 52% of microbeads are captured in activated sludge. Particle size analyses of the influent and effluent confirmed that smaller particles (up to 60-70 μm) are captured within activated sludge while bigger particles were detected in the effluent. Applying these data to the situation in Ljubljana indicates that about 112,500,000 particles may daily be released into the receiving river, resulting in a microbeads concentration of 21 particles/m 3 . Since polyethylene particles cannot be degraded and thus likely accumulate, the data raise concerns about potential effects in aquatic ecosystems in future. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. First Human Experience with Directly Image-able Iodinated Embolization Microbeads

    Energy Technology Data Exchange (ETDEWEB)

    Levy, Elliot B., E-mail: levyeb@cc.nih.gov; Krishnasamy, Venkatesh P. [National Institutes of Health, Center for Interventional Oncology (United States); Lewis, Andrew L.; Willis, Sean; Macfarlane, Chelsea [Biocompatibles, UK Ltd, A BTG International Group Company (United Kingdom); Anderson, Victoria [National Institutes of Health, Center for Interventional Oncology (United States); Bom, Imramsjah MJ van der [Clinical Science IGT Systems North & Latin America, Philips, Philips, Image Guided Interventions (United States); Radaelli, Alessandro [Image-Guided Therapy Systems, Philips, Philips, Image Guided Interventions (Netherlands); Dreher, Matthew R. [Biocompatibles, UK Ltd, A BTG International Group Company (United Kingdom); Sharma, Karun V. [Children’s National Medical Center (United States); Negussie, Ayele; Mikhail, Andrew S. [National Institutes of Health, Center for Interventional Oncology (United States); Geschwind, Jean-Francois H. [Department of Radiology and Biomedical Imaging (United States); Wood, Bradford J. [National Institutes of Health, Center for Interventional Oncology (United States)

    2016-08-15

    PurposeTo describe first clinical experience with a directly image-able, inherently radio-opaque microspherical embolic agent for transarterial embolization of liver tumors.MethodologyLC Bead LUMI™ is a new product based upon sulfonate-modified polyvinyl alcohol hydrogel microbeads with covalently bound iodine (~260 mg I/ml). 70–150 μ LC Bead LUMI™ iodinated microbeads were injected selectively via a 2.8 Fr microcatheter to near complete flow stasis into hepatic arteries in three patients with hepatocellular carcinoma, carcinoid, or neuroendocrine tumor. A custom imaging platform tuned for LC LUMI™ microbead conspicuity using a cone beam CT (CBCT)/angiographic C-arm system (Allura Clarity FD20, Philips) was used along with CBCT embolization treatment planning software (EmboGuide, Philips).ResultsLC Bead LUMI™ image-able microbeads were easily delivered and monitored during the procedure using fluoroscopy, single-shot radiography (SSD), digital subtraction angiography (DSA), dual-phase enhanced and unenhanced CBCT, and unenhanced conventional CT obtained 48 h after the procedure. Intra-procedural imaging demonstrated tumor at risk for potential under-treatment, defined as paucity of image-able microbeads within a portion of the tumor which was confirmed at 48 h CT imaging. Fusion of pre- and post-embolization CBCT identified vessels without beads that corresponded to enhancing tumor tissue in the same location on follow-up imaging (48 h post).ConclusionLC Bead LUMI™ image-able microbeads provide real-time feedback and geographic localization of treatment in real time during treatment. The distribution and density of image-able beads within a tumor need further evaluation as an additional endpoint for embolization.

  13. Multiplex competitive microbead-based flow cytometric immunoassay using quantum dot fluorescent labels

    International Nuclear Information System (INIS)

    Yu, Hye-Weon; Kim, In S.; Niessner, Reinhard; Knopp, Dietmar

    2012-01-01

    Highlights: ► First time, duplex competitive bead-based flow cytometric immunoassay was developed using ODs. ► Antibody-coated QD detection probes and antigen-immobilized microspheres were synthesized. ► The two model target analytes were low molecular weight compounds of microbial and chemical origin. ► The determination of different water types was possible after simple filtration of samples. - Abstract: In answer to the ever-increasing need to perform the simultaneous analysis of environmental hazards, microcarrier-based multiplex technologies show great promise. Further integration with biofunctionalized quantum dots (QDs) creates new opportunities to extend the capabilities of multicolor flow cytometry with their unique fluorescence properties. Here, we have developed a competitive microbead-based flow cytometric immunoassay using QDs fluorescent labels for simultaneous detection of two analytes, bringing the benefits of sensitive, rapid and easy-of-manipulation analytical tool for environmental contaminants. As model target compounds, the cyanobacterial toxin microcystin-LR and the polycyclic aromatic hydrocarbon compound benzo[a]pyrene were selected. The assay was carried out in two steps: the competitive immunological reaction of multiple targets using their exclusive sensing elements of QD/antibody detection probes and antigen-coated microsphere, and the subsequent flow cytometric analysis. The fluorescence of the QD-encoded microsphere was thus found to be inversely proportional to target analyte concentration. Under optimized conditions, the proposed assay performed well within 30 min for the identification and quantitative analysis of the two environmental contaminants. For microcystin-LR and benzo[a]pyrene, dose–response curves with IC 50 values of 5 μg L −1 and 1.1 μg L −1 and dynamic ranges of 0.52–30 μg L −1 and 0.13–10 μg L −1 were obtained, respectively. Recovery was 92.6–106.5% for 5 types of water samples like bottled

  14. Design of cissus-alginate microbeads revealing mucoprotection properties in anti-inflammatory therapy.

    Science.gov (United States)

    Okunlola, Adenike; Odeku, Oluwatoyin A; Lamprecht, Alf; Oyagbemi, Ademola A; Oridupa, Olayinka A; Aina, Oluwasanmi O

    2015-08-01

    Cissus gum has been employed as polymer with sodium alginate in the formulation of diclofenac microbeads and the in vivo mucoprotective properties of the polymer in anti-inflammatory therapy assessed in rats with carrageenan-induced paw edema in comparison to diclofenac powder and commercial diclofenac tablet. A full 2(3) factorial experimental design has been used to investigate the influence of concentration of cissus gum (X1); concentration of calcium acetate (X2) and stirring speed (X3) on properties of the microbeads. Optimized small discrete microbeads with size of 1.22±0.10 mm, entrapment efficiency of 84.6% and t80 of 15.2±3.5 h were obtained at ratio of cissus gum:alginate (1:1), low concentration of calcium acetate (5% w/v) and high stirring speed (400 rpm). In vivo studies showed that the ranking of percent inhibition of inflammation after 3h was diclofenac powder>commercial tablet=cissus>alginate. Histological damage score and parietal cell density were lower while crypt depth and mucosal width were significantly higher (pdiclofenac microbeads than those administered with diclofenac powder and commercial tablet, suggesting the mucoprotective property of the gum. Thus, cissus gum could be suitable as polymer in the formulation of non-steroidal anti-inflammatory drugs ensuring sustained release while reducing gastric side effects. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. Evaluation of Influenza-Specific Humoral Response by Microbead Array Analysis

    Directory of Open Access Journals (Sweden)

    Yoav Keynan

    2011-01-01

    Full Text Available RATIONALE: Quantitation and determination of antigen specificity of systemic and mucosal immune responses to influenza vaccination is beneficial for future vaccine development. Previous methods to acquire this information were costly, time consuming and sample exhaustive. The benefits of suspension microbead array (MBA analysis are numerous. The multiplex capabilities of the system conserve time, money and sample, while generating statistically powerful data.

  16. Enzyme-linked immunosorbent assay (ELISA for measles antibody: a comparison with haemagglutination inhibition, immunofluorescence and plaque neutralization tests Reação imunoenzimática (ELISA para detecção de anticorpos para o vírus do sarampo: comparação com reações de inibição da hema-glutinação, imunofluorescência indireta e neutralização de placas

    Directory of Open Access Journals (Sweden)

    Vanda Akico Ueda Fick de Souza

    1991-02-01

    Full Text Available An enzyme-linked immunosorbent assay (ELISA for measles antibodies was compared with Plaque Neutralization (PRN, Haemagglutination inhibition (HI and Fluorescent antibody (IFA tests in 181 sera from vaccinated children and umbilical cord. Of 179 positive samples by the sensitive PRN, only two, with titers of 8, were negative by ELISA (copositivity of 98.9%. IFA and HI presented, respectively, copo-sitivities of 93.3% and 82.7%. The ELISA presented a high sensitivity as well as a good reproducibility and represents an alternative for the time consuming PRN for detection of low measles antibodies.A reação imunoenzimática (ELISA para determinação de anticorpos para o vírus do sarampo foi comparada com a reação de neutralização de placas (RNP, inibição da hemaglutinação (RIH e imunofluorescência indireta (RIF. Das 179 amostras positivas pela RNP, somente 2, com títulos iguais a 8, se apresentaram negativas por ELISA (copositividade de 98.9%. A RIF e RIH apresentaram, respectivamente, copositividade de 93.3 e 82.7%. ELISA apresentou sensibilidade equivalente à complexa RNP, boa reprodutibilidade e representa uma alternativa para a detecção de baixos títulos de anticorpos contra o sarampo.

  17. Avaliação do método imunoenzimático (ELISA para diagnóstico da infecção por Helicobacter pylori em crianças e adolescentes Evaluation of enzyme-linked immunosorbent assay for the diagnosis of Helicobacter pylori infection in children and adolescents

    Directory of Open Access Journals (Sweden)

    Aurea Portorreal

    2002-07-01

    Full Text Available RACIONAL: A infecção por Helicobacter pylori é reconhecida como a causa mais freqüente de gastrite crônica em adultos e crianças. Seu diagnóstico é realizado com métodos invasivos em fragmentos de mucosa gástrica obtidos com pinça endoscópica e os não-invasivos. O método imunoenzimático constitui exame simples, rápido e de baixo custo, apresentando alta sensibilidade em pacientes adultos. OBJETIVO: Avaliou-se o método ELISA prospectivamente em 111 crianças e adolescentes. MATERIAL E MÉTODOS: Utilizou-se o kit "Cobas Core II" (Roche. Considerou-se Helicobacter pylori positivo quando o teste rápido da urease e a histologia resultaram ambos positivos ou quando a cultura foi positiva, e Helicobacter pylori negativo quando todos os testes foram negativos. RESULTADOS: A idade dos 111 pacientes variou de 3 meses a 16 anos, (mediana = 9a 5m; média = 8a 7m ± 4.0. Infecção por Helicobacter pylori foi diagnosticada em 47,7% (53/111. A sensibilidade da sorologia foi de 83,0% e 86,0% e a especificidade foi de 70,6% e 71,0%, utilizando o ponto de corte de 7 U/mL e 5 U/mL, respectivamente. Em pacientes maiores de 10 anos de idade, a sensibilidade foi de 90,6% e 96,8% e a especificidade 71,0% e 61,9%, com ponto de corte de 7 U/mL e 5 U/mL, respectivamente. Quando foi utilizada somente a cultura positiva como padrão ouro e ponto de corte em 5 U/mL, a sensibilidade foi de 93,3%. CONCLUSÃO: O método ELISA apresentou boa sensibilidade em crianças maiores de 10 anos, utilizando o ponto de corte de 5 U/mL, porém a especificidade foi menor.BACKGROUND: Helicobacter pylori infection is recognized as the most frequent cause of chronic gastritis in adults and children. The diagnosis is accomplished with invasive methods in fragments of endoscopic gastric biopsies and non-invasive methods. The enzyme-linked immunosorbent assay constitutes a simple, fast exam and of low cost with high sensibility in adult patients. AIM: The purpose of this study

  18. Design of indirect solid-phase immunosorbent methods for detecting arenavirus antigens and antibodies

    Energy Technology Data Exchange (ETDEWEB)

    Ivanov, A P; Rezapkin, G V; Dzagurova, T K; Tkachenko, E A

    1984-05-01

    Specifications have been elaborated for formulating indirect solid-phase enzyme-linked immunosorbent assay (ELISA) and radioimmunoassay (SPRIA) methods that employ anti-human and anti-mice G class immunoglobulin (IgG), conjugated with horseradish peroxidase and /sup 125/I for detecting the arenaviruses Junin, Machupo, Tacaribe, Amalpari, Tamiami, Lassa, and LCM (lymphocytic choriomeningitis). These methods make it possible to identify with a high degree of sensitivity arenavirus antigens and antibodies in various kinds of material.

  19. Design of a sensitive aptasensor based on magnetic microbeads-assisted strand displacement amplification and target recycling.

    Science.gov (United States)

    Li, Ying; Ji, Xiaoting; Song, Weiling; Guo, Yingshu

    2013-04-03

    A cross-circular amplification system for sensitive detection of adenosine triphosphate (ATP) in cancer cells was developed based on aptamer-target interaction, magnetic microbeads (MBs)-assisted strand displacement amplification and target recycling. Here we described a new recognition probe possessing two parts, the ATP aptamer and the extension part. The recognition probe was firstly immobilized on the surface of MBs and hybridized with its complementary sequence to form a duplex. When combined with ATP, the probe changed its conformation, revealing the extension part in single-strand form, which further served as a toehold for subsequent target recycling. The released complementary sequence of the probe acted as the catalyst of the MB-assisted strand displacement reaction. Incorporated with target recycling, a large amount of biotin-tagged MB complexes were formed to stimulate the generation of chemiluminescence (CL) signal in the presence of luminol and H2O2 by incorporating with streptavidin-HRP, reaching a detection limit of ATP as low as 6.1×10(-10)M. Moreover, sample assays of ATP in Ramos Burkitt's lymphoma B cells were performed, which confirmed the reliability and practicality of the protocol. Copyright © 2013 Elsevier B.V. All rights reserved.

  20. Controlled swelling and degradation studies of alginate microbeads in dilute natrium-citrate solutions

    Directory of Open Access Journals (Sweden)

    Mitrović Dragana D.

    2010-01-01

    Full Text Available Alginate hydrogels are widely used in biomedicine due to alginate availability, hydrophilic nature, biocompatibility and biodegradability. Alginate microbeads are particularly attractive for applications in pharmacy and regenerative medicine due to high surface to volume ratio, low mass transfer limitations and simple implantation by injection. Aim of this work was to investigate possibilities for controlled degradation of alginate microbeads in cell culture medium (Dulbecco’s modified Eagle’s medium with Na-citrate added in small concentrations (0.05 - 0.5 mM. Alginate microbeads (1.5% w/w, 800 m in diameter were produced by electrostatic droplet extrusion and evaluated over a period of 10 days regarding appearance, kinetics and degree of swelling as well as biomechanical properties determined in a novel bioreactor with mechanical stimulation under in vivo-like conditions in articular cartilage (10% strain, 337.5 m/s compression rate. In the citrate concentration range investigated, microbeads initially swelled reaching an equilibrium value (~150-170% with respect to the initial mass, upon which they appeared stable for a certain period of time (1 to over 7 days followed by bead bursting and degradation. This degradation process indicated that Na+ ions from the solution initially replaced Ca2+ ions bound mainly to COO- groups in polymannuronate sequences inducing electrostatic repulsion of polymer chains and, consequently, swelling of the beads. Citrate ions assisted in this process by forming insoluble calcium citrate. Thus, the specific rate of the bead swelling increased with the increase in citrate concentration approaching a maximal value of ~0.34 d-1. In the last phase, the beads burst into pieces, which slowly continued to degrade by replacement of Ca2+ ions bonded to polyguluronate blocks in the egg-box structure. Compression moduli for packed beds of control, freshly produced microbeads, and microbeads swelled at the equilibrium

  1. Determinação da infecção por Entamoeba histolytica em residentes da área metropolitana de Belém, Pará, Brasil, utilizando ensaio imunoenzimático (ELISA para detecção de antígenos Determination of Entamoeba histolytica infection in patients from Greater Metropolitan Belém, Pará, Brazil, by enzyme-linked immunosorbent assay (ELISA for antigen detection

    Directory of Open Access Journals (Sweden)

    Mônica Cristina de Moraes Silva

    2005-06-01

    Full Text Available O status epidemiológico da amebíase está sendo reavaliado desde que a Entamoeba histolytica (patogênica foi considerada espécie distinta de Entamoeba dispar (não patogênica. Em nosso estudo, realizamos pesquisa de antígenos de E. histolytica em amostras fecais de pacientes residentes na cidade de Belém, Pará, Brasil, utilizando ensaio imunoenzimático (E. histolytica Test, TechLab Inc., Blacksburg, Estados Unidos disponível comercialmente. Foram analisadas 845 amostras, com positividade em 248 (29,35%. A infecção por E. histolytica foi maior no grupo etário acima de 14 anos (30,36% que no grupo de 0-14 anos (28,28%, porém sem significância estatística (p The epidemiological status of amebiasis has been reevaluated since Entamoeba histolytica (pathogenic was considered a distinct species from Entamoeba dispar (non-pathogenic. We investigated E. histolytica antigens in stool samples from residents of Belém, Pará State, Brazil, with commercially available enzyme-linked immunosorbent assay (E. histolytica Test, TechLab Inc., Blacksburg, USA. A total of 845 samples were analyzed, of which 248 were positive (29.35%. E. histolytica infection was more frequent in the over-14-year age group (30.36% than in the 0-14-year group (28.28%, but the difference was not statistically significant (p < 0.05. Of all the samples, 334 were also submitted to parasitological methods (direct, Hoffman, and Faust et al.. There were discordant results between ELISA and parasitological methods in 83 samples (24.85%, with more positive results using ELISA. Our results thus suggest that intestinal amebiasis is an important public health problem in Greater Metropolitan Belém.

  2. Cell-density-dependent lysis and sporulation of Myxococcus xanthus in agarose microbeads.

    OpenAIRE

    Rosenbluh, A; Nir, R; Sahar, E; Rosenberg, E

    1989-01-01

    Vegetative cells of Myxococcus xanthus were immobilized in 25-microns-diameter agarose microbeads and incubated in either growth medium or sporulation buffer. In growth medium, the cells multiplied, glided to the periphery, and then filled the beads. In sporulation buffer, up to 90% of the cells lysed and ca. 50% of the surviving cells formed resistant spores. A strong correlation between sporulation and cell lysis was observed; both phenomena were cell density dependent. Sporulation proficie...

  3. Preparation of Nanofibrous Structure of Mesoporous Bioactive Glass Microbeads for Biomedical Applications

    Directory of Open Access Journals (Sweden)

    Shiao-Wen Tsai

    2016-06-01

    Full Text Available A highly ordered, mesoporous (pore size 2~50 nm bioactive glass (MBG structure has a greater surface area and pore volume and excellent bone-forming bioactivity compared with traditional bioactive glasses (BGs. Hence, MBGs have been used in drug delivery and bone tissue engineering. MBGs can be developed as either a dense or porous block. Compared with a block, microbeads provide greater flexibility for filling different-shaped cavities and are suitable for culturing cells in vitro. In contrast, the fibrous structure of a scaffold has been shown to increase cell attachment and differentiation due to its ability to mimic the three-dimensional structure of natural extracellular matrices. Hence, the aim of this study is to fabricate MBG microbeads with a fibrous structure. First, a sol-gel/electrospinning technique was utilized to fabricate the MBG nanofiber (MBGNF structure. Subsequently, the MBGNF microbeads (MFBs were produced by an electrospraying technology. The results show that the diameter of the MFBs decreases when the applied voltage increases. The drug loading and release profiles and mechanisms of the MFBs were also evaluated. MFBs had a better drug entrapment efficiency, could reduce the burst release of tetracycline, and sustain the release over 10 days. Hence, the MFBs may be suitable drug carriers. In addition, the cellular attachment of MG63 osteoblast-like cells is significantly higher for MFBs than for glass microbeads after culturing for 4 h. The nanofibrous structure of MFBs could provide an appropriate environment for cellular spreading. Therefore, MFBs have great potential for use as a bone graft material in bone tissue engineering applications.

  4. Cyanide Removal Efficiency of Photocatalytic Nanoparticles Stabilized on Glass Microbeads Under Sun Irradiation

    Directory of Open Access Journals (Sweden)

    Neda Masoudipour

    2017-01-01

    Full Text Available This paper investigates cyanide photodestruction (at pH 9 using the S, N-TiO2 photocatalyst synthesized by the sol-gel method and stabilized on glass microbeads. The main raw materials were thiourea, as a source of N and S, and tetra butyl ortho titanate. The effects of S and N doses, visible light (a 400W light, sunlight, irradiation time, and different initial cyanide concentrations (50, 100, 200, and 300 ppm were studied on cyanide photodestruction. Cyanide concentration was measured by the titration method and the photocatalyst film was characterized by X-ray diffraction (XRD, UV-Vis diffuse reflection spectroscopy (DRS, Scanning Electron Microscopy (SEM, and Energy dispersive X-ray (EDX analysis. XRD patterns and SEM images were used to determine the nanoparticle size of the photocatalyst on glass microbeads. EDX and DRS analyses confirmed the presence of S and N as well as the activity of the photocatalyst in the visible region, respectively. The S, N-TiO2 film with 0.25 g Thiuourea proved to be the best cyanide photodestruction agent in the visible light. Based on the results obtained, S, N-TiO2/ glass microbead was capable of destroying cyanide (50 ppm by up to 94% in the visible light and by approximately 100% in the sunlight. The results also indicated that S, N-Tio2/scoria stone was capable of destroying cyanide by 85% in the visible light and by 94% in the sunlight within 4 h.  The reaction kinetic for all cyanide concentrations and two photocatalyst substrates were described by a first order equation. Finally, it was concluded that the S, N-TiO2 stabilized on glass microbeads could be effectively used as a new method for treating wastewater containing free cyanide under the sunlight.

  5. Ion-imprinted polymethacrylic microbeads as new sorbent for preconcentration and speciation of mercury.

    Science.gov (United States)

    Dakova, Ivanka; Karadjova, Irina; Georgieva, Ventsislava; Georgiev, George

    2009-04-30

    Metal ion-imprinted polymer particles have been prepared by copolymerization of methacrylic acid as monomer, trimethylolpropane trimethacrylate as cross-linking agent and 2,2'-azobisisobutyronitrile as initiator, in the presence of Hg(II)-1-(2-thiazolylazo)-2-naphthol complex. The separation and preconcentration characteristics of the Hg-ion-imprinted microbeads for inorganic mercury have been investigated by batch procedure. The optimal pH value for the quantitative sorption is 7. The adsorbed inorganic mercury is easily eluted by 2 mL 4M HNO(3). The adsorption capacity of the newly synthesized Hg ion-imprinted microbeads is 32.0 micromol g(-1) for dry copolymer. The selectivity of the copolymer toward inorganic mercury (Hg(II)) ion is confirmed through the comparison of the competitive adsorptions of Cd(II), Co(II), Cu(II), Ni(II), Pb(II), Zn(II)) and high values of the selectivity and distribution coefficients have been calculated. Experiments performed for selective determination of inorganic mercury in mineral and sea waters showed that the interfering matrix does not influence the extraction efficiency of Hg ion-imprinted microbeads. The detection limit for inorganic mercury is 0.006 microg L(-1) (3 sigma), determined by cold vapor atomic adsorption spectrometry. The relative standard deviation varied in the range 5-9 % at 0.02-1 microg L(-1) Hg levels. The new Hg-ion-imprinted microbeads have been tested and applied for the speciation of Hg in river and mineral waters: inorganic mercury has been determined selectively in nondigested sample, while total mercury e.g. sum of inorganic and methylmercury, has been determined in digested sample.

  6. Successful subretinal delivery and monitoring of MicroBeads in mice.

    Directory of Open Access Journals (Sweden)

    M Dominik Fischer

    Full Text Available To monitor viability of implanted genetically engineered and microencapsulated human stem cells (MicroBeads in the mouse eye, and to study the impact of the beads and/or xenogenic cells on retinal integrity.MicroBeads were implanted into the subretinal space of SV126 wild type mice using an ab externo approach. Viability of microencapsulated cells was monitored by noninvasive retinal imaging (Spectralis™ HRA+OCT. Retinal integrity was also assessed with retinal imaging and upon the end of the study by light and electron microscopy. The implanted GFP-marked cells encapsulated in subretinal MicroBeads remained viable over a period of up to 4 months. Retinal integrity and viability appeared unaltered apart from the focal damage due to the surgical implantation, GFAP upregulation, and opsin mistargeting in the immediate surrounding tissue.The accessibility for routine surgery and its immune privileged state make the eye an ideal target for release system implants for therapeutic substances, including neurotrophic and anti-angiogenic compounds or protein based biosimilars. Microencapsulated human stem cells (MicroBeads promise to overcome limitations inherent with single factor release systems, as they are able to produce physiologic combinations of bioactive compounds.

  7. Encapsulation of Lactobacillus kefiri in alginate microbeads using a double novel aerosol technique.

    Science.gov (United States)

    Demitri, Christian; Lamanna, Leonardo; De Benedetto, Egidio; Damiano, Fabrizio; Cappello, Maria Stella; Siculella, Luisa; Sannino, Alessandro

    2017-08-01

    Alginate micro beads containing Lactobacillus kefiri (the principal bacteria present in the kefir probiotic drink) were produced by a novel technique based on dual aerosols spaying of alginate based solution and CaCl 2 as cross linking agent. Carboxymethylcellulose (CMC) has been also added to the alginate in order to change the physic-chemical properties (viscosity and permeability) of the microbeads. Calcium alginate and CMC are biopolymers that can be used for developing oral drug-delivery systems. These biopolymers have been reported to show a pH-dependent swelling behaviour. Calcium alginate and CMC have also been known to possess an excellent mucoadhesive property. The loaded microbeads have been characterized in terms of morphology, chemical composition and stability in different conditions mimicking the gastric environment. In this study, we demonstrate the feasibility of a continuous fabrication of alginate microbeads in a range of 50-70μm size, encapsulating L. kefiri as active ingredient. The technique involves the use of a double aerosols of alginate based solution and CaCl 2 as crosslinking agent. Moreover, the encapsulation process was proved to be effective and not detrimental to bacteria viability. At the same time, it was verified the protective efficacy of the microcapsules against the gastric environment using both SGF pH1.2 (fasted state) and pH2.2 (feed state). Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Separation and purification of hyaluronic acid by glucuronic acid imprinted microbeads

    Energy Technology Data Exchange (ETDEWEB)

    Akdamar, H.Acelya; Sarioezlue, Nalan Yilmaz [Department of Biology, Anadolu University, Eskisehir (Turkey); Ozcan, Ayca Atilir; Ersoez, Arzu [Department of Chemistry, Anadolu University, Eskisehir (Turkey); Denizli, Adil [Department of Chemistry, Hacettepe University, Ankara (Turkey); Say, Ridvan, E-mail: rsay@anadolu.edu.tr [Department of Chemistry, Anadolu University, Eskisehir (Turkey); BIBAM (Plant, Drug and Scientific Researches Center), Anadolu University, Eskisehir (Turkey)

    2009-05-05

    The purification of hyaluronic acid (HA) is relatively significant to use in biomedical applications. The structure of HA is formed by the repetitive units of glucuronic acid and N-acetyl glucosamine. In this study, glucuronic acid-imprinted microbeads have been supplied for the purification of HA from cell culture (Streptococcus equi). Histidine-functional monomer, methacryloylamidohistidine (MAH) was chosen as the metal-complexing monomer. The glucuronic acid-imprinted poly(ethyleneglycoldimethacrylate-MAH-Copper(II)) [p(EDMA-MAH-Cu{sup 2+})] microbeads have been synthesized by typical suspension polymerization procedure. The template glucuronic acid has been removed by employing 5 M methanolic KOH solution. p(EDMA-MAH-Cu{sup 2+}) microbeads have been characterized by elemental analysis, Fourier transform infrared spectroscopy (FTIR), scanning electron microscopy (SEM) images and swelling studies. Moreover, HA adsorption experiments have been performed in a batch experimental set-up. Purification of HA from cell culture supernatant has been also investigated by determining the hyaluronidase activity using purified HA as substrate. The glucuronic acid imprinted p(EDMA-MAH-Cu{sup 2+}) particles can be used many times with no significant loss in adsorption capacities. Also, the selectivity of prepared molecular imprinted polymers (MIP) has been examined. Results have showed that MIP particles are 19 times more selective for glucuronic acid than N-acetylglucose amine.

  9. Towards a high throughput droplet-based agglutination assay

    KAUST Repository

    Kodzius, Rimantas; Castro, David; Foulds, Ian G.

    2013-01-01

    This work demonstrates the detection method for a high throughput droplet based agglutination assay system. Using simple hydrodynamic forces to mix and aggregate functionalized microbeads we avoid the need to use magnetic assistance or mixing structures. The concentration of our target molecules was estimated by agglutination strength, obtained through optical image analysis. Agglutination in droplets was performed with flow rates of 150 µl/min and occurred in under a minute, with potential to perform high-throughput measurements. The lowest target concentration detected in droplet microfluidics was 0.17 nM, which is three orders of magnitude more sensitive than a conventional card based agglutination assay.

  10. Towards a high throughput droplet-based agglutination assay

    KAUST Repository

    Kodzius, Rimantas

    2013-10-22

    This work demonstrates the detection method for a high throughput droplet based agglutination assay system. Using simple hydrodynamic forces to mix and aggregate functionalized microbeads we avoid the need to use magnetic assistance or mixing structures. The concentration of our target molecules was estimated by agglutination strength, obtained through optical image analysis. Agglutination in droplets was performed with flow rates of 150 µl/min and occurred in under a minute, with potential to perform high-throughput measurements. The lowest target concentration detected in droplet microfluidics was 0.17 nM, which is three orders of magnitude more sensitive than a conventional card based agglutination assay.

  11. Redox-responsive microbeads containing thiolated pectin-doxorubicin conjugate inhibit tumor growth and metastasis: An in vitro and in vivo study.

    Science.gov (United States)

    Cheewatanakornkool, Kamonrak; Niratisai, Sathit; Dass, Crispin R; Sriamornsak, Pornsak

    2018-07-10

    The objective of this study was to investigate the in vitro cytotoxicity and in vivo anticancer efficacy of redox-responsive microbeads containing thiolated pectin-doxorubicin (DOX) conjugate. Oral microbeads were coated with an enteric polymer to protect the drug from release in the upper gastrointestinal (GI) tract and allow redox-triggered drug release in the colon. Morphology, particle size, drug content, and in vitro drug release behavior of the microbeads were characterized; in vitro cytotoxicity was tested on mouse colon carcinoma, human colorectal adenocarcinoma, and human bone osteosarcoma cell lines. In vivo anticancer efficacy of coated microbeads was examined in BALB/c mice with murine colon carcinoma. These coated microbeads significantly inhibited the growth of all cell lines. The in vivo study confirmed delivery of DOX to the colorectal tumor site, redox-responsiveness, and anticancer efficacy of coated microbeads. Coated microbeads also effectively inhibited primary tumor growth and suppressed tumor metastases without gross toxicity to the non-target tissue. No noticeable damage was found in mouse GI tissues, indicating lack of DOX toxicity. These novel coated microbeads containing thiolated pectin-DOX conjugate may be a promising vehicle for targeted clinical delivery of DOX to the colorectal cancer site by oral administration. Crown Copyright © 2018. Published by Elsevier B.V. All rights reserved.

  12. Study of cross-reactivity in serum samples from dogs positive for Leishmania sp., Babesia canis and Ehrlichia canis in enzyme-linked immunosorbent assay and indirect fluorescent antibody test Estudo da reatividade cruzada em amostras de soro de cães positivos para Leishmania sp., Babesia canis e Ehrlichia canis, pelo ensaio imunoenzimático indireto e pela reação de imunofluorescência indireta

    Directory of Open Access Journals (Sweden)

    Trícia Maria F. de Sousa Oliveira

    2008-03-01

    Full Text Available To verify the presence of cross-reaction among leishmaniosis, ehrlichiosis and babesiosis in serological diagnostics used in human visceral leishmaniasis control programs, serum samples from leishmaniasis endemic and non-endemic areas were collected and tested by Indirect Fluorescent Antibody (IFAT and Enzyme-linked immunosorbent assay (ELISA. All serum samples from endemic areas were positive for Leishmania sp., by ELISA and IFAT, 51% positive for Babesia canis and 43% for Ehrlichia canis by IFAT. None of the serum samples from non-endemic areas were positive for Leishmania sp., by IFAT, but 67% were positive for B. canis and 78% for E. canis using the same test. When tested by ELISA for Leishmania sp., four samples from non-endemic area were positive. These dogs were then located and no clinical signs, parasites or antibody was detected in new tests for a six month period. Only one of these 4 samples was positive for B. canis by IFAT and ELISA and three for E. canis by IFAT. The results of the work suggest a co-infection in the endemic area and no serological cross-reaction among these parasites by IFAT and ELISA.Para verificar a existência de reação cruzada entre leishmaniose visceral, erliquiose e babesiose, nos testes sorológicos utilizados em programas de controle da leishmaniose visceral humana, amostras de soro canino provenientes de áreas endêmicas e não endêmicas para essa enfermidade, foram testadas pela Reação de Imunofluorescência (RIFI e Ensaio imunoenzimático (ELISA. Todos os soros provenientes de área endêmica foram positivos para Leishmania sp pelo ELISA e RIFI, 51% para Babesia canis e 43% para Ehrlichia canis pela RIFI. Pela RIFI, nenhum dos soros provenientes de área não endêmica foi positivo para Leishmania sp, sendo 67% positivos para B. canis e 78% para E. canis pelo mesmo teste. Quando testados pelo ELISA para Leishmania sp., quatro soros da área não endêmica foram positivos. Os cães foram localizados

  13. Physical manipulation of single-molecule DNA using microbead and its application to analysis of DNA-protein interaction

    International Nuclear Information System (INIS)

    Kurita, Hirofumi; Yasuda, Hachiro; Takashima, Kazunori; Katsura, Shinji; Mizuno, Akira

    2009-01-01

    We carried out an individual DNA manipulation using an optical trapping for a microbead. This manipulation system is based on a fluorescent microscopy equipped with an IR laser. Both ends of linear DNA molecule were labeled with a biotin and a thiol group, respectively. Then the biotinylated end was attached to a microbead, and the other was immobilized on a thiol-linkable glass surface. We controlled the form of an individual DNA molecule by moving the focal point of IR laser, which trapped the microbead. In addition, we applied single-molecule approach to analyze DNA hydrolysis. We also used microchannel for single-molecule observation of DNA hydrolysis. The shortening of DNA in length caused by enzymatic hydrolysis was observed in real-time. The single-molecule DNA manipulation should contribute to elucidate detailed mechanisms of DNA-protein interactions

  14. Preparation and in vitro evaluation of carboxymethylated κ-carrageenan aluminum hydrogel microbeads for prolonged release of mefenamic acid

    International Nuclear Information System (INIS)

    Beron, Pia Maria G.; Cruzado, Shervin T.; Dela Cruz, Sharmaine F.; Estanislao, Fides Mae L.; Evangelista, Charina Joy; Mandocdoc, Larra Minnellie W.; Salas, Sharlaine B.; Tiu, Mark Brian C.; Carigma, Andrea Q.; Bayquen, Aristea V.

    2012-01-01

    Polymers that swell in an aqueous medium have been widely used to formulate controlled-release dosage forms. This study aims to prepare carboxymethyl κ-carrageenan (CMKC) microbeads and evaluate its potential for controlled release of mefenamic acid in comparison to the positive control, carboxymethylcellulose (CMC) microbeads. The powdered κ-carrageenan was carboxymethylated and Fourier-Transform Infrared Spectroscopy confirmed the carboxy methylation. Aqueous solutions of CMC (3% w/v) and CMKC (3%, 4%, 5% w/v) were prepared as microbeads using ionotropic gelation technique. Microbeads were loaded with mefenamic acid by suspending it in the aqueous solution (0.5% w/v) of the drug for 72 hours. Particle size and surface morphology were characterized using scanning electron microscopy. One-way ANOVA was used to determine a significant difference between the release activity of the drug-loaded CMKC and CMC microbeads. Differential Scanning Calorimetry was performed on the drug, drug- free, and drug-loaded microbeads of CMC and CMKC. Two-way ANOVARM showed significant interaction in % drug release of the three groups being analyzed in respect to time effect (p≤0.001) and group effect (p≤0.001). Post Hoc Duncan Multiple Range Test showed that 3% CMC and 4% CMKC has equal average % drug release values and is significantly higher compared to the commercial mefenamic acid. Also, one way ANOVA showed that 3% CMC was able to release the drug with no significant difference in time (p = 0.159), while 4% CMKC (p < 0.001) and the commercial mefenamic acid (p≤0.001) were able to release the drug with significant difference in time (author)

  15. Ultrasound Characterization of Microbead and Cell Suspensions by Speed of Sound Measurements of Neutrally Buoyant Samples

    DEFF Research Database (Denmark)

    Cushing, Kevin W.; Garofalo, Fabio; Magnusson, Cecilia

    2017-01-01

    . The density of the microparticles is determined by using a neutrally buoyant selection process that involves centrifuging of microparticles suspended in different density solutions, CsCl for microbeads and Percoll for cells. The speed of sound at 3 MHz in the neutrally buoyant suspensions is measured...... and fixed cells, such as red blood cells, white blood cells, DU-145 prostate cancer cells, MCF-7 breast cancer cells, and LU-HNSCC-25 head and-neck squamous carcinoma cells in phosphate buffered saline. The results show agreement with published data obtained by other methods....

  16. Formation of microbeads during vapor explosions of Field's metal in water

    KAUST Repository

    Kouraytem, Nadia; Li, Erqiang; Thoroddsen, Sigurdur T

    2016-01-01

    We use high-speed video imaging to investigate vapor explosions during the impact of a molten Field's metal drop onto a pool of water. These explosions occur for temperatures above the Leidenfrost temperature and are observed to occur in up to three stages as the metal temperature is increased, with each explosion being more powerful that the preceding one. The Field's metal drop breaks up into numerous microbeads with an exponential size distribution, in contrast to tin droplets where the vapor explosion deforms the metal to form porous solid structures. We compare the characteristic bead size to the wavelength of the fastest growing mode of the Rayleigh-Taylor instability.

  17. Microcapsules and 3D customizable shelled microenvironments from laser direct-written microbeads.

    Science.gov (United States)

    Kingsley, David M; Dias, Andrew D; Corr, David T

    2016-10-01

    Microcapsules are shelled 3D microenvironments, with a liquid core. These core-shelled structures enable cell-cell contact, cellular proliferation and aggregation within the capsule, and can be utilized for controlled release of encapsulated contents. Traditional microcapsule fabrication methods provide limited control of capsule size, and are unable to control capsule placement. To overcome these limitations, we demonstrate size and spatial control of poly-l-lysine and chitosan microcapsules, using laser direct-write (LDW) printing, and subsequent processing, of alginate microbeads. Additionally, microbeads were used as volume pixels (voxels) to form continuous 3D hydrogel structures, which were processed like capsules, to form custom shelled aqueous-core 3D structures of prescribed geometry; such as strands, rings, and bifurcations. Heterogeneous structures were also created with controlled initial locations of different cell types, to demonstrate the ability to prescribe cell signaling (heterotypic and homotypic) in co-culture conditions. Herein, we demonstrate LDW's ability to fabricate intricate 3D structures, essentially with "printed macroporosity," and to precisely control structural composition by bottom-up fabrication in a bead-by-bead manner. The structural and compositional control afforded by this process enables the creation of a wide range of new constructs, with many potential applications in tissue engineering and regenerative medicine. Biotechnol. Bioeng. 2016;113: 2264-2274. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  18. Size-amplified acoustofluidic separation of circulating tumor cells with removable microbeads

    Science.gov (United States)

    Liu, Huiqin; Ao, Zheng; Cai, Bo; Shu, Xi; Chen, Keke; Rao, Lang; Luo, Changliang; Wang, Fu-Bin; Liu, Wei; Bondesson, Maria; Guo, Shishang; Guo, Feng

    2018-06-01

    Isolation and analysis of rare circulating tumor cells (CTCs) is of great interest in cancer diagnosis, prognosis, and treatment efficacy evaluation. Acoustofluidic cell separation becomes an attractive method due to its contactless, noninvasive, simple, and versatile features. However, the indistinctive physical difference between CTCs and normal blood cells limits the purity of CTCs using current acoustic methods. Herein, we demonstrate a size-amplified acoustic separation and release of CTCs with removable microbeads. CTCs selectively bound to size-amplifiers (40 μm-diameter anti-EpCAM/gelatin-coated SiO2 microbeads) have significant physical differences (size and mechanics) compared to normal blood cells, resulting in an amplification of acoustic radiation force approximately a hundredfold over that of bare CTCs or normal blood cells. Therefore, CTCs can be efficiently sorted out with size-amplifiers in a traveling surface acoustic wave microfluidic device and released from size-amplifiers by enzymatic degradation for further purification or downstream analysis. We demonstrate a cell separation from blood samples with a total efficiency (E total) of ∼ 77%, purity (P) of ∼ 96%, and viability (V) of ∼83% after releasing cells from size-amplifiers. Our method substantially improves the emerging application of rare cell purification for translational medicine.

  19. Padronização de ensaio imunoenzimático para pesquisa de anticorpos das classes IgM e IgG anti-Toxoplasma gondii e comparação com a técnica de imunofluorescência indireta Standardization of enzyme-linked immunosorbent assay ELISA to detect anti-Toxoplasma gondii IgM and IgG antibodies, and comparison with the indirect immunofluorescence technique

    Directory of Open Access Journals (Sweden)

    Cláudia Maria Antunes Uchôa

    1999-12-01

    Full Text Available A sorologia tem sido o método de escolha para o diagnóstico da toxoplasmose. Devido a isto, padronizamos um ensaio imunoenzimático (ELISA e comparamos seus resultados com a técnica de imunofluorescência indireta (IFI. A técnica padronizada apresentou na pesquisa de IgG sensibilidade (S de 96,7% e especificidade (E de 75%, com valor de predição de positividade (VPP de 83,3% e de negatividade (VPN de 94,7%, com uma concordância ajustada (K de 73,5%. A IFI apresentou S de 83,8%, E de 79,1% com VPP de 83,8 % e VPN de 79,1% com K de 63%. A concordância bruta entre os dois testes (ELISA/IFI foi de 88,3% para pesquisa de IgG e de 81,5% para pesquisa de IgM, sendo o K de 70,8% para IgG e de 1,3% para IgM, sendo o índice de correlação (r de 0,556 para IgG e de -0,023 para IgM. Podemos concluir que a ELISA-IgG padronizada é indicada nos processos de triagem sorológica, sendo a ELISA-IgM desaconselhada uma vez que apresentou baixos índices de concordância ajustada com a técnica de referência, sugerindo pouca confiabilidade dos resultados.Serology has been the most popular method to diagnose toxoplasmosis. Accordingly, this study standardizes an enzyme-linked immunosorbent assay (ELISA and compares its results with the IFI technique. In the IgG detection test, the standardized technique presented a sensibility (S of 96.77%, a specificity (SP of 75%, with a positive predictive value (PPV of 83.33%, a negative predictive value (NPV of 94.74%, and an adjusted concordance (K of 73.50%. The IFI exhibited 83.87% for S, 79.16% for SP, 83.81% for PPV, 79.16% for NPV, and 63% for K. The rough concordance between these two tests (ELISA/IFI was 88.35% for the IgG detection test and 81.55% for the IgM detection test. K was 70.82% and 1.31% for IgG and IgM, respectively, the correlation index (r being 0.556 for IgG and -0.023 for IgM. We can conclude that standardized ELISA-IgG is indicated in serologic selection processes, whereas the ELISA-IgM is

  20. Umbilical cord stem cells released from alginate-fibrin microbeads inside macroporous and biofunctionalized calcium phosphate cement for bone regeneration

    Science.gov (United States)

    Chen, Wenchuan; Zhou, Hongzhi; Weir, Michael D.; Bao, Chongyun; Xu, Hockin H.K.

    2012-01-01

    The need for bone repair has increased as the population ages. The objectives of this study were to (1) develop a novel biofunctionalized and macroporous calcium phosphate cement (CPC) containing alginate-fibrin microbeads encapsulating human umbilical cord mesenchymal stem cells (hUCMSCs); and (2) investigate hUCMSC proliferation and osteogenic differentiation inside CPC for the first time. Macroporous CPC was developed using calcium phosphate powders, chitosan, and gas-foaming porogen. Five types of CPCs were fabricated: CPC control, CPC + 0.05% fibronectin (Fn), CPC + 0.1% Fn, CPC + 0.1% Arg-Gly-Asp (RGD), and CPC + 0.1% Fn + 0.1% RGD. Alginate-fibrin microbeads containing 106 hUCMSCs/mL were encapsulated in the CPC paste. After CPC had set, the degradable microbeads released hUCMSCs inside CPC. hUCMScs proliferated inside CPC, with cell density at 21 d being 4-fold that at 1 d. CPC + 0.1% RGD had the highest cell density, which was 4-fold that of CPC control. The released cells differentiated into the osteogenic lineage and synthesized bone minerals. hUCMSCs inside the CPC + 0.1% RGD construct had gene expressions of alkaline phosphatase (ALP), osteocalcin (OC) and collagen I, which were twice those of CPC control. Mineral synthesis by hUCMSCs inside the CPC + 0.1% RGD construct was 2-fold that in CPC control. RGD and Fn incorporation in CPC did not compromise the strength of CPC, which matched the reported strength of cancellous bone. In conclusion, degradable microbeads released the hUCMSCs which proliferated, differentiated and synthesized minerals inside the macroporous CPC for the first time. CPC with RGD greatly enhanced cell functions. The novel biofunctionalized and macroporous CPC-microbead-hUCMSC construct is promising for bone tissue engineering applications. PMID:22391411

  1. Sequential injection chemiluminescence immunoassay for nonionic surfactants by using magnetic microbeads

    International Nuclear Information System (INIS)

    Zhang Ruiq; Nakajima, Hizuru; Soh, Nobuaki; Nakano, Koji; Masadome, Takashi; Nagata, Kazumi; Sakamoto, Kazuhira; Imato, Toshihiko

    2007-01-01

    A rapid and sensitive immunoassay based on a sequential injection analysis (SIA) using magnetic microbeads for the determination of alkylphenol polyethoxylates (APnEOs) is described. An SIA system was constructed from a syringe pump, a switching valve, a flow-through type immunoreaction cell equipped with a photon counting unit and a neodymium magnet. Magnetic beads, to which an anti-APnEOs monoclonal antibody was immobilized, were used as a solid support in an immunoassay. The introduction, trapping and release of the magnetic beads in and from the immunoreaction cell were controlled by means of a neodymium magnet and adjusting the flow of a carrier solution. The immunoassay was based on an indirect competitive immunoreaction of an anti-APnEOs monoclonal antibody immobilized on the magnetic beads with a sample APnEOs and a horseradish peroxidase (HRP)-labeled APnEOs in the same sample solution, and was based on the subsequent chemiluminscence reaction of HRP on the magnetic microbeads with a luminol solution containing hydrogen peroxide and p-iodophenol. The anti-APnEOs antibody was immobilized on the magnetic microbeads by coupling the antibody with the magnetic beads after activation of a carboxylate moiety on the surface of the magnetic beads that had been coated with a polylactic acid film. The antibody immobilized magnetic beads were introduced in the immunoreaction cell and trapped in it by the neodymium magnet, which was equipped beneath the immunoreaction cell. An APnEOs sample solution containing the HRP-labeled APnEOs at a constant concentration, and a luminol solution containing hydrogen peroxide and p-iodophenol were sequentially introduced into the immunoreaction cell, according to an SIA programmed sequence. Chemiluminescence emission was monitored by means of a photon counting unit located at the upper side of the immunoreaction cell by collecting the emitted light with a lens. A typical sigmoidal calibration curve was obtained, when the logarithm

  2. A “turn-on” fluorescent microbead sensor for detecting nitric oxide

    Directory of Open Access Journals (Sweden)

    Yang LH

    2014-12-01

    Full Text Available Lan-Hee Yang,1,2 Dong June Ahn,3 Eunhae Koo1 1Advanced Materials Convergence Division, Korea Institute of Ceramic Engineering and Technology, Seoul, Republic of Korea; 2Department of Biomicrosystem Technology, Korea University, Seoul, Republic of Korea; 3Departments of Biomicrosystem Technology, Chemical & Biological Engineering, KU-KIST Graduate School, Korea University, Seoul, Republic of Korea Abstract: Nitric oxide (NO is a messenger molecule involved in numerous physical and pathological processes in biological systems. Therefore, the development of a highly sensitive material able to detect NO in vivo is a key step in treating cardiovascular and a number of types of cancer-related diseases, as well as neurological dysfunction. Here we describe the development of a fluorescent probe using microbeads to enhance the fluorescence signal. Microbeads are infused with the fluorophore, dansyl-piperazine (Ds-pip, and quenched when the fluorophore is coordinated with a rhodium (Rh-complex, ie, Rh2(AcO-4(Ds-pip. In contrast, they are able to fluoresce when the transition-metal complex is replaced by NO. To confirm the “on/off” mechanism for detecting NO, we investigated the structural molecular properties using the Fritz Haber Institute ab initio molecular simulations (FHI-AIMS package. According to the binding energy calculation, NO molecules bind more strongly and rapidly with the Rh-core of the Rh-complex than with Ds-pip. This suggests that NO can bond strongly with the Rh-core and replace Ds-pip, even though Ds-pip is already near the Rh-core. However, the recovery process takes longer than the quenching process because the recovery process needs to overcome the energy barrier for formation of the transition state complex, ie, NO-(AcO-4-(Ds-pip. Further, we confirm that the Rh-complex with the Ds-pip structure has too small an energy gap to give off visible light from the highest unoccupied molecular orbital/lowest unoccupied molecular

  3. Electrolytic deposition of Sn-coated mesocarbon microbeads as anode material for lithium ion battery

    Energy Technology Data Exchange (ETDEWEB)

    Deng, Min-Jen [Department of Materials Engineering, National Chung Hsing University, Taichung 40227, Taiwan (China); Jen-Teh Junior College of Medicine, Nursing and Management, Taiwan (China); Tsai, Du-Cheng [Department of Materials Engineering, National Chung Hsing University, Taichung 40227, Taiwan (China); Ho, Wen-Hsien [Taiwan Textile Research Institute, Taipei 23674, Taiwan (China); Li, Ching-Fei, E-mail: chingfei.li@gmail.com [Phoenix Silicon International Corporation, Hsinchu 30094, Taiwan (China); Shieu, Fuh-Sheng, E-mail: fsshieu@dragon.nchu.edu.tw [Department of Materials Engineering, National Chung Hsing University, Taichung 40227, Taiwan (China); Center of Nanoscience and Nanotechnology, National Chung Hsing University, Taichung 40227, Taiwan (China)

    2013-11-15

    Deposited of crystalline tin (Sn) coatings on mesocarbon microbead (MCMB) powder as anodes of lithium ion (Li-ion) battery was conducted in the SnSO{sub 4} solution by a cathodic electrochemical synthesis. The Sn-coated MCMB specimens were characterized by X-ray diffraction, scanning electron microscopy, and charge/discharge tests. The synthesis condition of Sn-coated MCMB was optimized by considering the agglomeration, size, and adhesion of the samples to the current collectors in the battery. The Sn-coated MCMB electrodes exhibit increased reversible capacity without sacrificing its cycling behavior, compared with bare MCMB electrodes. It is concluded that electrolysis-deposited Sn-coated MCMB electrodes may emerge as a practical and promising anode material for secondary Li-ion batteries.

  4. Formation of microbeads during vapor explosions of Field's metal in water

    KAUST Repository

    Kouraytem, Nadia

    2016-06-17

    We use high-speed video imaging to investigate vapor explosions during the impact of a molten Field\\'s metal drop onto a pool of water. These explosions occur for temperatures above the Leidenfrost temperature and are observed to occur in up to three stages as the metal temperature is increased, with each explosion being more powerful that the preceding one. The Field\\'s metal drop breaks up into numerous microbeads with an exponential size distribution, in contrast to tin droplets where the vapor explosion deforms the metal to form porous solid structures. We compare the characteristic bead size to the wavelength of the fastest growing mode of the Rayleigh-Taylor instability.

  5. Relationship between microhardness and fatigue strength after glass micro-bead peening and ion implantation

    International Nuclear Information System (INIS)

    Lunarski, J.; Zielecki, M.

    1989-01-01

    Results of tests on fatigue strength and condition of the surface layer, produced by ion implantation or/and glass micro-bead peening for E1961Sz and 12H2N4MAZ steels and WT3-1 titanium alloy are reported. In the tests the following characteristics are measured: Knoop hardness, residual stresses (by etching method), surface roughness, and oscillatory bending fatigue limit at the resonance frequency of the specimen. The test results indicate that for the examined steels there is a strong correlation between surface microhardness and fatigue limit, in spite of various surface treatments. This fact enables to predict changes in the fatigue limit, basing on the results of surface microhardness measurements, which are inexpensive and easy to perform. (author)

  6. Electrolytic deposition of Sn-coated mesocarbon microbeads as anode material for lithium ion battery

    International Nuclear Information System (INIS)

    Deng, Min-Jen; Tsai, Du-Cheng; Ho, Wen-Hsien; Li, Ching-Fei; Shieu, Fuh-Sheng

    2013-01-01

    Deposited of crystalline tin (Sn) coatings on mesocarbon microbead (MCMB) powder as anodes of lithium ion (Li-ion) battery was conducted in the SnSO 4 solution by a cathodic electrochemical synthesis. The Sn-coated MCMB specimens were characterized by X-ray diffraction, scanning electron microscopy, and charge/discharge tests. The synthesis condition of Sn-coated MCMB was optimized by considering the agglomeration, size, and adhesion of the samples to the current collectors in the battery. The Sn-coated MCMB electrodes exhibit increased reversible capacity without sacrificing its cycling behavior, compared with bare MCMB electrodes. It is concluded that electrolysis-deposited Sn-coated MCMB electrodes may emerge as a practical and promising anode material for secondary Li-ion batteries.

  7. Superparamagnetic microbead transport induced by a magnetic field on large-area magnetic antidot arrays

    Science.gov (United States)

    Ouk, Minae; Beach, Geoffrey S. D.

    2017-12-01

    A method is presented for directed transport of superparamagnetic microbeads (SPBs) on magnetic antidot patterned substrates by applying a rotating elliptical magnetic field. We find a critical frequency for transport, beyond which the bead dynamics transitions from stepwise locomotion to local oscillation. We also find that the out-of-plane (HOOP) and in-plane (HIP) field magnitudes play crucial roles in triggering bead motion. Namely, we find threshold values in HOOP and HIP that depend on bead size, which can be used to independently and remotely address specific bead populations in a multi-bead mixture. These behaviors are explained in terms of the dynamic potential energy lansdscapes computed from micromagnetic simulations of the substrate magnetization configuration. Finally, we show that large-area magnetic patterns suitable for particle transport and sorting can be fabricated through a self-assembly lithography technique, which provides a simple, cost-effective means to integrate magnetic actuation into microfluidic systems.

  8. Comparison of a commercial ELISA and an immunoperoxidase monolayer assay to detect antibodies directed against porcine respiratory and reproductive syndrome virus

    NARCIS (Netherlands)

    Nodelijk, G.; Wensvoort, G.; Kroese, B.; Leengoed, van L.A.M.G.; Colijn, E.; Verheijden, J.H.M.

    1996-01-01

    A commercially available enzyme-linked immunosorbent assay (ELISA) for the detection of antibodies against porcine respiratory and reproductive syndrome virus (PRRSV) was compared to an immunoperoxidase monolayer assay (IPMA). Serum samples used were collected from pigs experimentally infected with

  9. A new index for characterizing micro-bead motion in a flow induced by ciliary beating: Part II, modeling.

    Directory of Open Access Journals (Sweden)

    Mathieu Bottier

    2017-07-01

    Full Text Available Mucociliary clearance is one of the major lines of defense of the human respiratory system. The mucus layer coating the airways is constantly moved along and out of the lung by the activity of motile cilia, expelling at the same time particles trapped in it. The efficiency of the cilia motion can experimentally be assessed by measuring the velocity of micro-beads traveling through the fluid surrounding the cilia. Here we present a mathematical model of the fluid flow and of the micro-beads motion. The coordinated movement of the ciliated edge is represented as a continuous envelope imposing a periodic moving velocity boundary condition on the surrounding fluid. Vanishing velocity and vanishing shear stress boundary conditions are applied to the fluid at a finite distance above the ciliated edge. The flow field is expanded in powers of the amplitude of the individual cilium movement. It is found that the continuous component of the horizontal velocity at the ciliated edge generates a 2D fluid velocity field with a parabolic profile in the vertical direction, in agreement with the experimental measurements. Conversely, we show than this model can be used to extract microscopic properties of the cilia motion by extrapolating the micro-bead velocity measurement at the ciliated edge. Finally, we derive from these measurements a scalar index providing a direct assessment of the cilia beating efficiency. This index can easily be measured in patients without any modification of the current clinical procedures.

  10. Design of a Modular DNA Triangular-Prism Sensor Enabling Ratiometric and Multiplexed Biomolecule Detection on a Single Microbead.

    Science.gov (United States)

    Liu, Yu; Chen, Qiaoshu; Liu, Jianbo; Yang, Xiaohai; Guo, Qiuping; Li, Li; Liu, Wei; Wang, Kemin

    2017-03-21

    DNA nanostructures have emerged as powerful and versatile building blocks for the construction of programmable nanoscale structures and functional sensors for biomarker detection, disease diagnostics, and therapy. Here we integrated multiple sensing modules into a single DNA three-dimensional (3D) nanoarchitecture with a triangular-prism (TP) structure for ratiometric and multiplexed biomolecule detection on a single microbead. In our design, the complementary hybridization of three clip sequences formed TP nanoassemblies in which the six single-strand regions in the top and bottom faces act as binding sites for different sensing modules, including an anchor module, reference sequence module, and capture sequence module. The multifunctional modular TP nanostructures were thus exploited for ratiometric and multiplexed biomolecule detection on microbeads. Microbead imaging demonstrated that, after ratiometric self-calibration analysis, the imaging deviations resulting from uneven fluorescence intensity distribution and differing probe concentrations were greatly reduced. The rigid nanostructure also conferred the TP as a framework for geometric positioning of different capture sequences. The inclusion of multiple targets led to the formation of sandwich hybridization structures that gave a readily detectable optical response at different fluorescence channels and distinct fingerprint-like pattern arrays. This approach allowed us to discriminate multiplexed biomolecule targets in a simple and efficient fashion. In this module-designed strategy, the diversity of the controlled DNA assembly coupled with the geometrically well-defined rigid nanostructures of the TP assembly provides a flexible and reliable biosensing approach that shows great promise for biomedical applications.

  11. Rapid single-step upconversion-linked immunosorbent assay for diclofenac

    Czech Academy of Sciences Publication Activity Database

    Hlaváček, Antonín; Peterek, M.; Farka, Z.; Mickert, M. J.; Prechtl, L.; Knopp, D.; Gorris, H H.

    2017-01-01

    Roč. 184, č. 10 (2017), s. 4159-4165 ISSN 0026-3672 R&D Projects: GA ČR(CZ) GBP206/12/G014 Institutional support: RVO:68081715 Keywords : bioconjugation * electrophoretic purification * immunoassay * luminescence Subject RIV: CB - Analytical Chemistry, Separation OBOR OECD: Analytical chemistry Impact factor: 4.580, year: 2016

  12. An enzyme-linked immunosorbent assay for measuring GPIHBP1 levels in human plasma or serum

    DEFF Research Database (Denmark)

    Miyashita, Kazuya; Fukamachi, Isamu; Nagao, Manabu

    2018-01-01

    Background: Glycosylphosphatidylinositol-anchored high-density lipoprotein-binding protein 1 (GPIHBP1), a glycosylphosphatidylinositol (GPI)-anchored protein of capillary endothelial cells, transports lipoprotein lipase to the capillary lumen and is essential for the lipolytic processing of trigl...

  13. Correlation between centromere protein-F autoantibodies and cancer analyzed by enzyme-linked immunosorbent assay

    DEFF Research Database (Denmark)

    Welner, Simon; Trier, Nicole Hartwig; Morten Frisch, Morten

    2013-01-01

    Centromere protein-F (CENP-F) is a large nuclear protein of 367 kDa, which is involved in multiple mitosis-related events such as proper assembly of the kinetochores, stabilization of heterochromatin, chromosome alignment and mitotic checkpoint signaling. Several studies have shown a correlation...

  14. DETECTION OF HUMAN BLOODSTAINS BY ENZYME-LINKED IMMUNOSORBENT ASSAY (ELISA

    Directory of Open Access Journals (Sweden)

    GHOLAM-HOSSEIN EDRISSIAN

    1982-07-01

    Full Text Available The microplate method of e nzyme-l i nke d i rnmuno s o r be n t a s s ay (ELISA , usi ng alkaline phosphatase anti-human I gG conj ugate , was modified and appl ied in t he dete c t i on of the human b lood specimens among the blood samples prep a r ed fr om human and laborat or y anima l s i n t he form of small dr ied b loodst a i ns on f ilt e r paper . The modi f i e d ELISA t e chnique wa s compa red wit h t he agar double d i f f us ion me t hod of prec ipitin test ."nThe results of this primary study showed t ha t the ELISA i n compare to gel diffusi o n t e st is sensitive and specific. It is also enough repr oducible and practical t o be consider as a competent technique for i de nt i f i c ation o f human bloodstains in medicolegal laboratories .

  15. [Evaluation of the Performance of Two Kinds of Anti-TP Enzyme-Linked Immunosorbent Assay].

    Science.gov (United States)

    Gao, Nan; Huang, Li-Qin; Wang, Rui; Jia, Jun-Jie; Wu, Shuo; Zhang, Jing; Ge, Hong-Wei

    2018-06-01

    To evaluate the accuracy and precision of 2 kinds of anti-treponema pallidum (anti-TP) ELISA reagents in our laboratory for detecting the anti-TP in voluntary blood donors, so as to provide the data support for use of ELISA reagents after introduction of chemiluminescene immunoassay (CLIA). The route detection of anti-TP was performed by using 2 kinds of ELISA reagents, then 546 responsive positive samples detected by anti-TP ELISA were collected, and the infections status of samples confirmed by treponema pallidum particle agglutination (TPPA) test was identified. The confirmed results of responsive samples detected by 2 kinds of anti-TP ELISA reagents were compared, the accuracy of 2 kinds of anti-TP ELISA reagents was analyzed by drawing ROC and comparing area under curve (AUC), and precision of 2 kinds of anti-TP ELISA reagents was compared by statistical analysis of quality control data from 7.1 2016 to 6.30 2017. There were no statistical difference in confirmed positive rate of responsive samples and weak positive samples between 2 kinds of anti-TP ELISA reagents. The responsive samples detected by 2 kinds of anti-TP ELISA reagents accounted for 85.53%(467/546) of all responsive samples, the positive rate confirmed by TPPA test was 82.87%. 44 responsive samples detected by anti-TP ELISA reagent A and 35 responsive samples detected by anti-TP ELISA reagent B were confirmed to be negative by TPPA test. Comparison of AUC showed that the accuracy of 2 kinds of anti-TP ELISA reagents was more high, the difference between 2 reagents was not statistically significant. The coefficient of variation (CV) of anti-TP ELISA reagent A and B was 14.98% and 18.04% respectively, which met the precision requirement of ELISA test. The accuracy and precision of 2 kinds of anti-TP ELISA reagents used in our laboratory are similar, and using any one of anti-TP ELISA reagents all can satisfy the requirements of blood screening.

  16. Validation of a KHV antibody enzyme-linked immunosorbent assay (ELISA)

    DEFF Research Database (Denmark)

    Bergmann, S M; Wang, Q; Zeng, W

    2017-01-01

    Koi herpesvirus (KHV) causes KHV disease (KHVD). The virus is highly contagious in carp or koi and can induce a high mortality. Latency and, in some cases, a lack of signs presents a challenge for virus detection. Appropriate immunological detection methods for anti-KHV antibodies have not yet be...

  17. Recombinant Plasmodium falciparum glutamate rich protein; purification and use in enzyme-linked immunosorbent assay

    DEFF Research Database (Denmark)

    Dziegiel, Morten Hanefeld; Borre, M B; Jepsen, S

    1991-01-01

    New Guinea (MAD20) and Honduras (HB3) completely absorbed specific antibodies, indicating the presence of conserved epitopes produced by all isolates of P. falciparum. Recombinant GLURP489-1271 ELISA is sensitive and rapid, and therefore well-suited for sero-epidemiological studies, and for control...

  18. AN ENZYME-LINKED IMMUNOSORBENT ASSAY (ELISA) FOR DETERMINING DIOXINS IN SEDIMENT AND SOIL SAMPLES

    Science.gov (United States)

    The dioxins comprise a family of compounds chemically referred to as polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs). The most toxic of these compounds is 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD), a known human carcinogen. Dioxins are formed ...

  19. Application of fluorescent antibody and enzyme-linked immunosorbent assays for TCE and PAH degrading bacteria

    Energy Technology Data Exchange (ETDEWEB)

    Brigmon, R.L.; Franck, M.; Brey, J.; Scott, D.; Lanclos, K.; Fliermans, C.

    1996-07-01

    Historically, methods used to identify methanotrophic and polyaromatic hydrocarbon-degrading (PAH) bacteria in environmental samples have been inadequate because isolation and identification procedures are time-consuming and often fail to separate specific bacteria from other environmental microorganisms. Methanotrophic bacteria have been isolated and characterized from TCE-contaminated soils (Bowman et al. 1993; Fliermans et al., 1988). Fliermans et al., (1988) and others demonstrated that cultures enriched with methane and propane could cometabolically degrade a wide variety of chlorinated aliphatic hydrocarbons including ethylene; 1,2-cisdichloroethylene (c-DCE); 1,2-trans-dichloroethylene (t-DCE); vinyl chloride (VC); toluene; phenol and cresol. Characterization of select microorganisms in the natural setting is important for the evaluation of bioremediation potential and its effectiveness. This realization has necessitated techniques that are selective, sensitive and easily applicable to soils, sediments, and groundwater (Fliermans, et al., 1994). Additionally these techniques can identify and quantify microbial types in situ in real time

  20. Detection of eosinophil cationic protein (ECP) by an enzyme-linked immunosorbent assay

    DEFF Research Database (Denmark)

    Reimert, C M; Venge, P; Kharazmi, A

    1991-01-01

    Eosinophil cationic protein (ECP) is a highly basic and potent cytotoxic single-chain zinc-containing protein present in the granules of the eosinophilic granulocytes. ECP appears to be involved in defence against parasites and in the tissue damage seen in subjects with allergic and inflammatory...... disease. To investigate ECP release from in vitro activated human eosinophils and to study the involvement of eosinophils in health and disease, we have developed a sensitive and specific enzyme immunoassay. ECP was purified from normal human peripheral blood eosinophils and polyclonal antibodies to ECP...

  1. Evaluation of a novel enzyme-linked immunosorbent assay for serological diagnosis of porcine proliferative enteropathy

    DEFF Research Database (Denmark)

    Boesen, Henriette Toft; Jensen, Tim Kåre; Møller, Kristian

    2005-01-01

    was a specific and sensitive method for detecting specific antibodies, and may be a good alternative to the existing serological tests for L intracellularis. It may be usable for diagnosis of proliferative enteropathy and for determination of a herd's epidemiologic status....... experimentally infected pigs and 62 serum samples from naturally infected pigs the sensitivity of the ELISA was calculated to 98.0%. The specificity of the test was 99.3%, calculated on the basis of 273 serum samples collected in six herds free of L. intracellularis after medicated eradication. The novel ELISA...

  2. Comparison of uncultured marrow mononuclear cells and culture-expanded mesenchymal stem cells in 3D collagen-chitosan microbeads for orthopedic tissue engineering.

    Science.gov (United States)

    Wise, Joel K; Alford, Andrea I; Goldstein, Steven A; Stegemann, Jan P

    2014-01-01

    Stem cell-based therapies have shown promise in enhancing repair of bone and cartilage. Marrow-derived mesenchymal stem cells (MSC) are typically expanded in vitro to increase cell number, but this process is lengthy, costly, and there is a risk of contamination and altered cellular properties. Potential advantages of using fresh uncultured bone marrow mononuclear cells (BMMC) include heterotypic cell and paracrine interactions between MSC and other marrow-derived cells including hematopoietic, endothelial, and other progenitor cells. In the present study, we compared the osteogenic and chondrogenic potential of freshly isolated BMMC to that of cultured-expanded MSC, when encapsulated in three-dimensional (3D) collagen-chitosan microbeads. The effect of low and high oxygen tension on cell function and differentiation into orthopedic lineages was also examined. Freshly isolated rat BMMC (25 × 10(6) cells/mL, containing an estimated 5 × 10(4) MSC/mL) or purified and culture-expanded rat bone marrow-derived MSC (2 × 10(5) cells/mL) were added to a 65-35 wt% collagen-chitosan hydrogel mixture and fabricated into 3D microbeads by emulsification and thermal gelation. Microbeads were cultured in control MSC growth media in either 20% O2 (normoxia) or 5% O2 (hypoxia) for an initial 3 days, and then in control, osteogenic, or chondrogenic media for an additional 21 days. Microbead preparations were evaluated for viability, total DNA content, calcium deposition, and osteocalcin and sulfated glycosaminoglycan expression, and they were examined histologically. Hypoxia enhanced initial progenitor cell survival in fresh BMMC-microbeads, but it did not enhance osteogenic potential. Fresh uncultured BMMC-microbeads showed a similar degree of osteogenesis as culture-expanded MSC-microbeads, even though they initially contained only 1/10th the number of MSC. Chondrogenic differentiation was not strongly supported in any of the microbead formulations. This study demonstrates the

  3. Differential growth of pavement cells of Arabidopsis thaliana leaf epidermis as revealed by microbead labeling.

    Science.gov (United States)

    Elsner, Joanna; Lipowczan, Marcin; Kwiatkowska, Dorota

    2018-02-01

    In numerous vascular plants, pavement cells of the leaf epidermis are shaped like a jigsaw-puzzle piece. Knowledge about the subcellular pattern of growth that accompanies morphogenesis of such a complex shape is crucial for studies of the role of the cytoskeleton, cell wall and phytohormones in plant cell development. Because the detailed growth pattern of the anticlinal and periclinal cell walls remains unknown, our aim was to measure pavement cell growth at a subcellular resolution. Using fluorescent microbeads applied to the surface of the adaxial leaf epidermis of Arabidopsis thaliana as landmarks for growth computation, we directly assessed the growth rates for the outer periclinal and anticlinal cell walls at a subcellular scale. We observed complementary tendencies in the growth pattern of the outer periclinal and anticlinal cell walls. Central portions of periclinal walls were characterized by relatively slow growth, while growth of the other wall portions was heterogeneous. Local growth of the periclinal walls accompanying lobe development after initiation was relatively fast and anisotropic, with maximal extension usually in the direction along the lobe axis. This growth pattern of the periclinal walls was complemented by the extension of the anticlinal walls, which was faster on the lobe sides than at the tips. Growth of the anticlinal and outer periclinal walls of leaf pavement cells is heterogeneous. The growth of the lobes resembles cell elongation via diffuse growth rather than tip growth. © 2018 Botanical Society of America.

  4. Near-field acoustic microbead trapping as remote anchor for single particle manipulation

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Jae Youn [Department of Information and Communication Engineering, Daegu Gyeongbuk Institute of Science and Technology, Daegu (Korea, Republic of); Cheon, Dong Young; Shin, Hyunjune; Kim, Hyun Bin; Lee, Jungwoo, E-mail: jwlee@kw.ac.kr [Department of Electronic Engineering, Kwangwoon University, Seoul (Korea, Republic of)

    2015-05-04

    We recently proposed an analytical model of a two-dimensional acoustic trapping of polystyrene beads in the ray acoustics regime, where a bead diameter is larger than the wavelength used. As its experimental validation, this paper demonstrates the transverse (or lateral) trapping of individual polystyrene beads in the near field of focused ultrasound. A 100 μm bead is immobilized on the central beam axis by a focused sound beam from a 30 MHz single element lithium niobate transducer, after being laterally displaced through hundreds of micrometers. Maximum displacement, a longest lateral distance at which a trapped bead can be directed towards the central axis, is thus measured over a discrete frequency range from 24 MHz to 36 MHz. The displacement data are found to be between 323.7 μm and 470.2 μm, depending on the transducer's driving frequency and input voltage amplitude. The experimental results are compared with their corresponding model values, and their relative errors lie between 0.9% and 3.9%. The results suggest that this remote maneuvering technique may be employed to manipulate individual cells through solid microbeads, provoking certain cellular reactions to localized mechanical disturbance without direct contact.

  5. Magnetic Microbead Affinity Selection Screening (MagMass) of Botanical Extracts for Inhibitors of 15-Lipoxygenase

    Science.gov (United States)

    Rush, Michael D.; Walker, Elisabeth M.; Burton, Tristesse; van Breemen, Richard B.

    2016-01-01

    To expedite the identification of active natural products in complex mixtures such as botanical extracts, a Magnetic Microbead Affinity Selection Screening (MagMASS) procedure was developed. This technique utilizes target proteins immobilized on magnetic beads for rapid bioaffinity isolation of ligands from complex mixtures. A MagMASS method was developed and validated for 15-lipoxygenase. As a proof of concept, several North American prairie plants used medicinally by Native Americans were extracted with MeOH and screened. A hit from an extract of Proserpinaca palustris, also known as mermaid weed, was flagged for further characterization using high-resolution tandem mass spectrometry, dereplication, and identification using XCMS online. Through the application of high-resolution product ion tandem mass spectrometry, comparison with natural product databases and confirmation using standards, the hit was identified as quercitrin, which is a known inhibitor of 15-lipoxygenase. The overall workflow of MagMASS is faster and more amendable to automation than alternative methods designed for screening botanical extracts or complex mixtures of combinatorial libraries. PMID:27802026

  6. Engineering novel synthetic strategy to develop mesocarbon microbeads for multi-functional applications

    Science.gov (United States)

    Chaudhary, Anisha; Teotia, Satish; Kumar, Rajeev; Ramesha, K.; Dhakate, Sanjay R.; Kumari, Saroj

    2018-04-01

    To assess the challenge of affordable technology, present synthetic strategies can be extended to new low-cost synthesis and processing methods that have potential to tailor the properties of the materials. Here we report, a novel method for the synthesis of mesocarbon microbeads (MCMB) through a pre-processing involved pyrolysis technique. The resulting MCMB is compressed into a product and effects of heat treatment temperature on different properties of MCMB is studied. The use of MCMB for the electromagnetic interference (EMI) shielding is new and hence, the effect of heat treatment temperature on EMI shielding effectiveness is studied in X-band. It is observed that EMI shielding effectiveness increases to ‑39.6 dB on increasing the heat treatment temperature. The high conductivity of MCMB plate heat treated upto 2500 °C contributes to highly conducting networks. Additionally, to investigate the electrochemical performance of MCMB as an anode material for lithium ion batteries, 2500 °C heat treated MCMB powder is used to fabricate the electrode. The MCMB electrode exhibits high discharge capacity of 345 mAh g‑1 with a stable capacity for over 50 cycles and good rate capability. Thus, MCMB synthesized by this novel approach can be used for the development of high performance anode materials for Li-ion batteries.

  7. Microplastic fragments and microbeads in digestive tracts of planktivorous fish from urban coastal waters

    Science.gov (United States)

    Tanaka, Kosuke; Takada, Hideshige

    2016-01-01

    We investigated microplastics in the digestive tracts of 64 Japanese anchovy (Engraulis japonicus) sampled in Tokyo Bay. Plastic was detected in 49 out of 64 fish (77%), with 2.3 pieces on average and up to 15 pieces per individual. All of the plastics were identified by Fourier transform infrared spectroscopy. Most were polyethylene (52.0%) or polypropylene (43.3%). Most of the plastics were fragments (86.0%), but 7.3% were beads, some of which were microbeads, similar to those found in facial cleansers. Eighty percent of the plastics ranged in size from 150 μm to 1000 μm, smaller than the reported size range of floating microplastics on the sea surface, possibly because the subsurface foraging behavior of the anchovy reflected the different size distribution of plastics between surface waters and subsurface waters. Engraulis spp. are important food for many humans and other organisms around the world. Our observations further confirm that microplastics have infiltrated the marine ecosystem, and that humans may be exposed to them. Because microplastics retain hazardous chemicals, increase in fish chemical exposure by the ingested plastics is of concern. Such exposure should be studied and compared with that in the natural diet. PMID:27686984

  8. Magnetic stimulus responsive vancomycin drug delivery system based on chitosan microbeads embedded with magnetic nanoparticles.

    Science.gov (United States)

    Mohapatra, Ankita; Harris, Michael A; LeVine, David; Ghimire, Madhav; Jennings, Jessica A; Morshed, Bashir I; Haggard, Warren O; Bumgardner, Joel D; Mishra, Sanjay R; Fujiwara, Tomoko

    2017-10-20

    Local antibiotic delivery can overcome some of the shortcomings of systemic therapy, such as low local concentrations and delivery to avascular sites. A localized drug delivery system (DDS), ideally, could also use external stimuli to modulate the normal drug release profile from the DDS to provide efficacious drug administration and flexibility to healthcare providers. To achieve this objective, chitosan microbeads embedded with magnetic nanoparticles were loaded with the antibiotic vancomycin and stimulated by a high frequency alternating magnetic field. Three such stimulation sessions separated by 1.5 h were applied to each test sample. The chromatographic analysis of the supernatant from these stimulated samples showed more than approximately 200% higher release of vancomycin from the DDS after the stimulation periods compared to nonstimulated samples. A 16-day long term elution study was also conducted where the DDS was allowed to elute drug through normal diffusion over a period of 11 days and stimulated on day 12 and day 15, when vancomycin level had dropped below therapeutic levels. Magnetic stimulation boosted elution of test groups above minimum inhibitory concentration (MIC), as compared to control groups (with no stimulation) which remained below MIC. The drug release from test groups in the intervals where no stimulation was given showed similar elution behavior to control groups. These results indicate promising possibilities of controlled drug release using magnetic excitation from a biopolymer-based DDS. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2017. © 2017 Wiley Periodicals, Inc.

  9. Activation of mesocarbon microbeads with different textures and their application for supercapacitor

    Energy Technology Data Exchange (ETDEWEB)

    Fuhu, Li; Weidong, Chi; Zengmin, Shen; Yunfang, Liu; Hui, Liu [Institute of Carbon Fibers and Composites, Beijing University of Chemical Technology, Beijing 100029 (China); Yixian, Wu [The Key Laboratory of Beijing City on Preparation and Processing of Novel Polymer Materials, Beijing University of Chemical Technology, Beijing 100029 (China)

    2010-01-15

    Three kinds of mesocarbon microbeads (MCMBs) with different textures were activated by potassium hydroxide at 900 C and used as electrode materials for supercapacitor. The effects of textures of precursors on electrochemical performances of activated MCMBs were investigated. Nitrogen sorption measurements (at 77 K) showed that three kinds of activated MCMBs possess high specific surface areas (> 2000 m{sup 2}/g) and different porosity characteristics. MCMB prepared by emulsion method from bulk mesophase pitch (MCMB-e) has an irregular and distorted lamellar structure of oriented aromatic hydrocarbons. The unique texture of MCMB-e leads to the largest specific surface area (2542.8 m{sup 2}/g) and the highest micropore volume (0.8236 cm{sup 3}/g) after activation. Galvanostatic charge-discharge results showed that the activated MCMB-e has the highest specific capacitance of 326 F/g at the current density of 20 mA/g and better rate capability in 6 M KOH electrolyte. The good capacitive behavior of the activated MCMB-e may be attributed to the high-surface area, abundant micropores, closed-packed mesopores and macropores, as well as moderate crystal structures. (author)

  10. Near-field acoustic microbead trapping as remote anchor for single particle manipulation

    Science.gov (United States)

    Hwang, Jae Youn; Cheon, Dong Young; Shin, Hyunjune; Kim, Hyun Bin; Lee, Jungwoo

    2015-05-01

    We recently proposed an analytical model of a two-dimensional acoustic trapping of polystyrene beads in the ray acoustics regime, where a bead diameter is larger than the wavelength used. As its experimental validation, this paper demonstrates the transverse (or lateral) trapping of individual polystyrene beads in the near field of focused ultrasound. A 100 μm bead is immobilized on the central beam axis by a focused sound beam from a 30 MHz sin