WorldWideScience

Sample records for micro-tubes visualization studies

  1. 3D visualization of two-phase flow in the micro-tube by a simple but effective method

    International Nuclear Information System (INIS)

    Fu, X; Zhang, P; Hu, H; Huang, C J; Huang, Y; Wang, R Z

    2009-01-01

    The present study provides a simple but effective method for 3D visualization of the two-phase flow in the micro-tube. An isosceles right-angle prism combined with a mirror located 45° bevel to the prism is employed to synchronously obtain the front and side views of the flow patterns with a single camera, where the locations of the prism and the micro-tube for clear imaging should satisfy a fixed relationship which is specified in the present study. The optical design is proven successfully by the tough visualization work at the cryogenic temperature range. The image deformation due to the refraction and geometrical configuration of the test section is quantitatively investigated. It is calculated that the image is enlarged by about 20% in inner diameter compared to the real object, which is validated by the experimental results. Meanwhile, the image deformation by adding a rectangular optical correction box outside the circular tube is comparatively investigated. It is calculated that the image is reduced by about 20% in inner diameter with a rectangular optical correction box compared to the real object. The 3D re-construction process based on the two views is conducted through three steps, which shows that the 3D visualization method can easily be applied for two-phase flow research in micro-scale channels and improves the measurement accuracy of some important parameters of the two-phase flow such as void fraction, spatial distribution of bubbles, etc

  2. Experimental study of micro-shock tube flow

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jin Ouk; Kim, Gyu Wan; Rasel, Md. Alim Iftakhar [Dept. of Mechanical Engineering, Andong National University, Andong (Korea, Republic of); Kim, Heuy Dong [Fire Research Center, Korea Institute of Civil Engineering and Building Technology, Hwasung (Korea, Republic of)

    2015-03-15

    The flow characteristics in micro shock tube are investigated experimentally. Studies were carried out using a stainless steel micro shock tube. Shock and expansion wave was measured using 8 pressure sensors. The initial pressure ratio was varied from 4.3 to 30.5, and the diameter of tube was also changed from 3 mm to 6 mm. Diaphragm conditions were varied using two types of diaphragms. The results obtained show that the shock strength in the tube becomes stronger for an increase in the initial pressure ratio and diameter of tube. For the thinner diaphragm, the highest shock strength was found among varied diaphragm condition. Shock attenuation was highly influenced by the diameter of tube.

  3. Formability of Micro-Tubes in Hydroforming

    International Nuclear Information System (INIS)

    Hartl, Christoph; Anyasodor, Gerald; Lungershausen, Joern

    2011-01-01

    Micro-hydroforming is a down-scaled metal forming process, based on the expansion of micro-tubes by internal pressurization within a die cavity. The objective of micro-hydroforming is to provide a technology for the economic mass production of complex shaped hollow micro-components. Influence of size effects in metal forming processes increases with scaling down of metal parts. Investigations into the change in formability of micro-tubes due to metal part scaling down constituted an important subject within the conducted fundamental research work. Experimental results are presented, concerning the analysis of the formability of micro-tubes made from stainless steel AISI 304 with an outer diameter of 800 μm and a wall thickness of 40 μm. An average ratio of tube wall thickness to grain size of 1.54 of up to 2.56 was analyzed. Miniaturised mechanical standard methods as well as bulge tests with internal hydrostatic pressurization of the tubular specimens were applied to analyze the influence of size-dependent effects. A test device was developed for the bulge experiments which enabled the pressurization of micro-tubes with internal pressures up to 4000 bar. To determine the attainable maximum achievable expansion ratio the tubes were pressurized in the bulge tests with increasing internal pressure until instability due to necking and subsequent bursting occurred. Comparisons with corresponding tests of macro-tubes, made from the here investigated material, showed a change in formability of micro-tubes which was attributed to the scaling down of the hydroforming process. In addition, a restricted applicability of existing theoretical correlations for the determination of the maximum pressure at bursting was observed for down-scaled micro-hydroforming.

  4. Experimental Study on Cooling Heat Transfer of Supercritical Carbon Dioxide Inside Horizontal Micro-Fin Tubes

    Science.gov (United States)

    Kuwahara, Ken; Higashiiu, Shinya; Ito, Daisuke; Koyama, Shigeru

    This paper deals with the experimental study on cooling heat transfer of supercritical carbon dioxide inside micro-fin tubes. The geometrical parameters in micro-fin tubes used in the present study are 6.02 mm in outer diameter, 4.76 mm to 5.11 mm in average inner diameter, 0.15 mm to 0.24 mm in fin height, 5 to 25 in helix angle, 46 to 52 in number of fins and 1.4 to 2.3 in area expansion ratio. Heat transfer coefficients were measured at 8-10 MPa in pressure, 360-690 kg/(m2•s) in mass velocity and 20-75 °C in CO2 temperature. The measured heat transfer coefficients of micro-fin tubes were 1.4 to 2 times higher than those of the smooth tube having 4.42 in inner diameter. The predicted heat transfer coefficients using the correlation equation, which was developed for single-phase turbulent fluid flow inside micro-fin-tubes, showed large deviations to the measured values. The new correlation to predict cooling heat transfer coefficient of supercritical carbon dioxide inside micro-fin tubes was developed taking into account the shape of fins based on experimental data empirically. This correlation equation agreed within ±20% of almost all of the experimental data.

  5. Heat transfer performance during in-tube condensation in horizontal smooth, micro-fin and herringbone tubes

    OpenAIRE

    2008-01-01

    M.Ing. An experimental investigation was conducted into the heat transfer characteristics of horizontal smooth, micro-fin and herringbone tubes during in-tube condensation. The study focused on the heat transfer coefficients of refrigerants R-22, R-134a and R-407C inside the three tubes. The herringbone tube results were compared to the smooth and micro-fin tube results. The average increase in the heat transfer coefficient when compared to the smooth tube was found to be as high as 322% w...

  6. Tube micro-fouling, boiling and steam pressure after chemical cleaning

    International Nuclear Information System (INIS)

    Hu, M.H.

    1998-01-01

    This paper presents steam pressure trends after chemical cleaning of steam generator tubes at four plants. The paper also presents tube fouling factor that serves as an objective parameter to assess tubing boiling conditions for understanding the steam pressure trend. Available water chemistry data helps substantiate the concept of tube micro-fouling, its effect on tubing boiling, and its impact on steam pressure. All four plants experienced a first mode of decreasing steam pressure in the post-cleaning operation. After 3 to 4 months of operation, the decreasing trend stopped for three plants and then restored to a pre-cleaning value or better. The fourth plant is soil in decreasing trend after 12 months of operation. Dissolved chemicals, such as silica, titanium can precipitate on tube surface. The precipitate micro-fouling can deactivate or eliminate boiling nucleation sites. Therefore, the first phase of the post-cleaning operation suffered a decrease in steam pressure or an increase in fouling factor. It appears that micro fouling by magnetite deposit can activate or create more bubble nucleation sites. Therefore, the magnetite deposit micro-fouling results in a decrease in fouling factor, and a recovery in steam pressure. Fully understanding the boiling characteristics of the tubing at brand new, fouled and cleaned conditions requires further study of tubing surface conditions. Such study should include boiling heat transfer tests and scanning electronic microscope examination. (author)

  7. Two-phase flow characteristics of liquid nitrogen in vertically upward 0.5 and 1.0 mm micro-tubes: Visualization studies

    Science.gov (United States)

    Zhang, P.; Fu, X.

    2009-10-01

    Application of liquid nitrogen to cooling is widely employed in many fields, such as cooling of the high temperature superconducting devices, cryosurgery and so on, in which liquid nitrogen is generally forced to flow inside very small passages to maintain good thermal performance and stability. In order to have a full understanding of the flow and heat transfer characteristics of liquid nitrogen in micro-tube, high-speed digital photography was employed to acquire the typical two-phase flow patterns of liquid nitrogen in vertically upward micro-tubes of 0.531 and 1.042 mm inner diameters. It was found from the experimental results that the flow patterns were mainly bubbly flow, slug flow, churn flow and annular flow. And the confined bubble flow, mist flow, bubble condensation and flow oscillation were also observed. These flow patterns were characterized in different types of flow regime maps. The surface tension force and the size of the diameter were revealed to be the major factors affecting the flow pattern transitions. It was found that the transition boundaries of the slug/churn flow and churn/annular flow of the present experiment shifted to lower superficial vapor velocity; while the transition boundary of the bubbly/slug flow shifted to higher superficial vapor velocity compared to the results of the room-temperature fluids in the tubes with the similar hydraulic diameters. The corresponding transition boundaries moved to lower superficial velocity when reducing the inner diameter of the micro-tubes. Time-averaged void fraction and heat transfer characteristics for individual flow patterns were presented and special attention was paid to the effect of the diameter on the variation of void fraction.

  8. Experimental study on void fraction of two-phase flow inside a micro-fin tube

    OpenAIRE

    Koyama, Shigeru; Chen, Yongchang; Kitano, Ryuji; Kuwahara, Ken

    2001-01-01

    In this paper the void fraction and flow pattern of the two-phase flow in a micro-fin tube were investigated experimentally for a pure refrigerant HFC134a. The experiment was carried out at a pressure range of 0.6 and 1.2MPa with mass velocities of 90 and 180kg/m^2 s, in which the vapor quality varied from 0 to 1. The void fraction was measured by means of simultaneously closing valves of both sides of the test tube at adiabatic condition. Experimental results for the micro-fin tube were comp...

  9. A visual stethoscope to detect the position of the tracheal tube.

    Science.gov (United States)

    Kato, Hiromi; Suzuki, Akira; Nakajima, Yoshiki; Makino, Hiroshi; Sanjo, Yoshimitsu; Nakai, Takayoshi; Shiraishi, Yoshito; Katoh, Takasumi; Sato, Shigehito

    2009-12-01

    Advancing a tracheal tube into the bronchus produces unilateral breath sounds. We created a Visual Stethoscope that allows real-time fast Fourier transformation of the sound signal and 3-dimensional (frequency-amplitude-time) color rendering of the results on a personal computer with simultaneous processing of 2 individual sound signals. The aim of this study was to evaluate whether the Visual Stethoscope can detect bronchial intubation in comparison with auscultation. After induction of general anesthesia, the trachea was intubated with a tracheal tube. The distance from the incisors to the carina was measured using a fiberoptic bronchoscope. While the anesthesiologist advanced the tracheal tube from the trachea to the bronchus, another anesthesiologist auscultated breath sounds to detect changes of the breath sounds and/or disappearance of bilateral breath sounds for every 1 cm that the tracheal tube was advanced. Two precordial stethoscopes placed at the left and right sides of the chest were used to record breath sounds simultaneously. Subsequently, at a later date, we randomly entered the recorded breath sounds into the Visual Stethoscope. The same anesthesiologist observed the visualized breath sounds on the personal computer screen processed by the Visual Stethoscope to examine changes of breath sounds and/or disappearance of bilateral breath sound. We compared the decision made based on auscultation with that made based on the results of the visualized breath sounds using the Visual Stethoscope. Thirty patients were enrolled in the study. When irregular breath sounds were auscultated, the tip of the tracheal tube was located at 0.6 +/- 1.2 cm on the bronchial side of the carina. Using the Visual Stethoscope, when there were any changes of the shape of the visualized breath sound, the tube was located at 0.4 +/- 0.8 cm on the tracheal side of the carina (P Stethoscope (not significant). During advancement of the tracheal tube, alterations of the shape of the

  10. Experimental research of inclined-micro-fin flat tube on single phase convection heat transfer

    International Nuclear Information System (INIS)

    Fan Guangming; Sun Zhongning; Wang Meng

    2011-01-01

    The experimental research of heat transfer and flow resistance characteristics of single phase water in four inclined-micro-fin flat tubes with different physical dimensions was conducted. At the same time,suitable criteria were selected to evaluate the efficiency of inclined-micro-fin flat tubes within the experimental scope and the optimal working region was determined. The results indicate that inclined-micro-fin flat tubes can greatly enhance the single-phase heat transfer in turbulent flow and the maximum heat transfer coefficient attains to 5.9 times of that in smooth tube. The quantities of heat transfer for inclined-micro-fin flat tubes are three times higher than that of smooth tube with the same of heat exchange area and pump power. (authors)

  11. Enhancement of heat transfer. The performance of micro-fin tubes

    International Nuclear Information System (INIS)

    Muzzio, A.

    2001-01-01

    Micro-fin tubes are characterised by numerous, very small integral fins that spiral down the inner surface. A very interesting feature of their performance in flow boiling and condensation is a large heat transfer enhancement accompanied by a low pressure drop penalty. This paper presents a general overview of micro-fin tubes and of their performance in evaporation, condensation and single-phase flow [it

  12. Visual study of air--water mixtures flowing inside serpentine tubes

    International Nuclear Information System (INIS)

    Farukhi, M.N.; Parker, J.D.

    1974-01-01

    Hydrodynamic behavior of air-water mixtures flowing inside serpentine tubes, with bends in the vertical plane, was investigated. Flow visualization was accomplished by injecting dye into the liquid phase and recording the events on color slides and color movies. For certain combinations of gas and liquid flow rates, in the annular type flow regime, ''film inversion'' was observed in the bend as well as in the straight section immediately downstream of the bend. A new flow regime map particularly applicable to two phase flow inside serpentine tubes is presented. (U.S.)

  13. Micro tube heat exchangers for Space, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Mezzo fabricates micro tube heat exchangers for a variety of applications, including aerospace, automotive racing, Department of Defense ground vehicles, economizers...

  14. Numerical investigation on flow behavior and energy separation in a micro-scale vortex tube

    Directory of Open Access Journals (Sweden)

    Rahbar Nader

    2015-01-01

    Full Text Available There are a few experimental and numerical studies on the behaviour of micro-scale vortex tubes. The intention of this work is to investigate the energy separation phenomenon in a micro-scale vortex tube by using the computational fluid dynamic. The flow is assumed as steady, turbulent, compressible ideal gas, and the shear-stress transport sst k-w is used for modeling of turbulence phenomenon. The results show that 3-D CFD simulation is more accurate than 2-D axisymmetric one. Moreover, optimum cold-mass ratios to maximize the refrigeration-power and isentropicefficiency are evaluated. The results of static temperature, velocity magnitude and pressure distributions show that the temperature-separation in the micro-scale vortex tube is a function of kinetic-energy variation and air-expansion in the radial direction.

  15. Visual accumulation tube for size analysis of sands

    Science.gov (United States)

    Colby, B.C.; Christensen, R.P.

    1956-01-01

    The visual-accumulation-tube method was developed primarily for making size analyses of the sand fractions of suspended-sediment and bed-material samples. Because the fundamental property governing the motion of a sediment particle in a fluid is believed to be its fall velocity. the analysis is designed to determine the fall-velocity-frequency distribution of the individual particles of the sample. The analysis is based on a stratified sedimentation system in which the sample is introduced at the top of a transparent settling tube containing distilled water. The procedure involves the direct visual tracing of the height of sediment accumulation in a contracted section at the bottom of the tube. A pen records the height on a moving chart. The method is simple and fast, provides a continuous and permanent record, gives highly reproducible results, and accurately determines the fall-velocity characteristics of the sample. The apparatus, procedure, results, and accuracy of the visual-accumulation-tube method for determining the sedimentation-size distribution of sands are presented in this paper.

  16. Experimental research on single phase convection heat transfer in micro-fin tube

    International Nuclear Information System (INIS)

    Fan Guangming; Sun Zhongning; Zhu Sheng

    2011-01-01

    An experimental investigation of heat transfer and flow resistance characteristics of single phase water in three micro-fin tubes with different fin height was conducted. At the same time, the efficiency of micro-fin tubes within the experimental scope was evaluated and the optimal working region was determined. Based on the experimental data in the optimal working region, correlations for predicting the heat transfer and flow resistance were also given by multiple regression method. The result indicates that the micro-fin tubes can greatly enhance the single-phase heat transfer in turbulent flow, and the increase of heat transfer coefficient is higher than the increase of flow resistance. The accuracy of the correlation is very high, of which the deviation from the experimental value is very small. (authors)

  17. Study of the motion and deposition of micro particles in a vertical tube containing uniform gas flow

    Science.gov (United States)

    Abolpour, Bahador; Afsahi, M. Mehdi; Soltani Goharrizi, Ataallah; Azizkarimi, Mehdi

    2017-12-01

    In this study, effects of a gaseous jet, formed in a vertical tube containing a uniform gas flow, on the injected micro particles have been investigated. A CFD model has been developed to simulate the particle motion in the tube. This simulation is very close to the experimental data. The results show that, increasing the flow rate of carrier gas or decreasing the flow rate of surrounding gas increases the effect of gaseous jet and also increases trapping rate of the particles by the tube wall. The minimum and maximum residence times of particles approach together with increasing the size of solid particles. Particles larger than 60 μm have a certain and fixed residence time at different flow rates of the carrier or surrounding gas. About 40 μm particle size has minimal trapping by the tube wall at various experimental conditions.

  18. Superelastic NiTi memory alloy micro-tube under tension - nucleation and propagation of martensite band

    International Nuclear Information System (INIS)

    Li, Z.Q.; Sun, Q.P.

    2000-01-01

    The superelastic behavior of polycrystalline NiTi shape memory alloy micro-tube under tension is studied experimentally. The nominal stress-strain curve of the micro-tube is recorded. By using a special surface coating it is found that the deformation of the tube is via the nucleation and propagation of stress-induced martensite band. The experiments show that the martensite nucleates in the form of a spiral lens-shaped narrow band that is inclined at 61 to the axis of loading when the stress reaches the peak of stress-strain curve. The width and the length of the band grew gradually with increase of loading and finally joined and merged into a single band. The subsequent deformation of the tube is realized by the propagation of this cylindrical martensite band. (orig.)

  19. Experimental and numerical studies in a vortex tube

    International Nuclear Information System (INIS)

    Sohn, Chang Hyun; Kim, Chang Soo; Gowda, B. H. L Lakshmana; Jung, Ui Hyun

    2006-01-01

    The present investigation deals with the study of the internal flow phenomena of the counter-flow type vortex tube using experimental testing and numerical simulation. Visualization was carried out using the surface tracing method, injecting dye on the vortex tube wall using a needle. Vortex tube is made of acrylic to visualize the surface particle tracing and the input air pressure was varied from 0.1 MPa to 0.3 MPa. The experimentally visualized results on the tube show that there is an apparent sudden changing of the trajectory on the vortex tube wall which was observed in every experimental test case. This may indicate the stagnation position of the vortex flow. The visualized stagnation position moves towards the vortex generator with increase in cold flow ratio and input pressure. Three-dimensional computational study is also conducted to obtain more detailed flow information in the vortex tube. Calculated total pressure, static pressure and total temperature distributions in the vortex tube were in good agreement with the experimental data. The computational particle trace on the vortex tube wall is very similar to that observed in experiments

  20. Study on chromosome aberrations test determinated by micro-whole blood culture in vacuum blood collection tube

    International Nuclear Information System (INIS)

    Zhong Zhihong; Han Fang'an; Ge Qinjuan; Wu Xiao; Chen Juan

    2006-01-01

    Objective: To develop an easier and efficient method of culturing the chromosome and analyzing the aberrations in peripheral lymphocytes. Methods: Micro whole was cultured for 54 hours in home-made vacuum blood collection tube, and then collection, slice-making, microscopy detection for the chromosome aberrations was done. The difference of the results was analysed by comparing with the common method. Results: For 60 radiologists and 30 contrasts, the chromosome aberrations in peripheral lymphocytes were examed by this system, the lymphocytes and chromosome were clear and alive and easier to analyse. Compared with the common method, there was no significantly difference between the two analyzing results. Conclusion: The chromosome aberrations test by micro whole blood culture in vacuum blood collection tube is easier and efficient, and is worthy of being widely popularized. (authors)

  1. Single-stage micro-scale solvent extraction in parallel microbore tubes using MDIMJ

    International Nuclear Information System (INIS)

    Darekar, Mayur; Singh, K.K.; Joshi, J.M.; Mukhopadhyay, S.; Shenoy, K.T.

    2016-01-01

    Single-stage micro-scale solvent extraction of U(VI) from simulated lean streams is explored using micro-scale contactor comprising of a MDIMJ (Monoblock Distributor with Integrated Microfluidic Junction) and PTFE microbore tubes. 30% (v/v) TBP in dodecane has been used as the extracting phase. The objective of the study is to demonstrate numbering up approach for scale-up of micro-scale extraction using indigenously conceptualized and fabricated MDIMJ. First the performance of MIDIMJ for equal flow distribution is tested. Then the effects of inlet flow rate and O/A ratio on stage efficiency and percentage extraction are studied. The experiments show that it is easy to scale-up single-stage micro-scale solvent extraction by using MDIMJ for numbering up approach. Maximum capacity tested is 4.8 LPH. With O/A = 2/1, more than 90% extraction is achieved in a very short contact time of less than 3s. The study thus demonstrates possibility of process intensification and easy scale-up of micro-scale solvent extraction

  2. Direct ophthalmoscopy on YouTube: analysis of instructional YouTube videos' content and approach to visualization.

    Science.gov (United States)

    Borgersen, Nanna Jo; Henriksen, Mikael Johannes Vuokko; Konge, Lars; Sørensen, Torben Lykke; Thomsen, Ann Sofia Skou; Subhi, Yousif

    2016-01-01

    Direct ophthalmoscopy is well-suited for video-based instruction, particularly if the videos enable the student to see what the examiner sees when performing direct ophthalmoscopy. We evaluated the pedagogical effectiveness of instructional YouTube videos on direct ophthalmoscopy by evaluating their content and approach to visualization. In order to synthesize main themes and points for direct ophthalmoscopy, we formed a broad panel consisting of a medical student, junior and senior physicians, and took into consideration book chapters targeting medical students and physicians in general. We then systematically searched YouTube. Two authors reviewed eligible videos to assess eligibility and extract data on video statistics, content, and approach to visualization. Correlations between video statistics and contents were investigated using two-tailed Spearman's correlation. We screened 7,640 videos, of which 27 were found eligible for this study. Overall, a median of 12 out of 18 points (interquartile range: 8-14 key points) were covered; no videos covered all of the 18 points assessed. We found the most difficulties in the approach to visualization of how to approach the patient and how to examine the fundus. Time spent on fundus examination correlated with the number of views per week (Spearman's ρ=0.53; P=0.029). Videos may help overcome the pedagogical issues in teaching direct ophthalmoscopy; however, the few available videos on YouTube fail to address this particular issue adequately. There is a need for high-quality videos that include relevant points, provide realistic visualization of the examiner's view, and give particular emphasis on fundus examination.

  3. Creeping gaseous flows through elastic tube and annulus micro-configurations

    Science.gov (United States)

    Elbaz, Shai; Jacob, Hila; Gat, Amir

    2016-11-01

    Gaseous flows in elastic micro-configurations is relevant to biological systems (e.g. alveolar ducts in the lungs) as well as to applications such as gas actuated soft micro-robots. We here examine the effect of low-Mach-number compressibility on creeping gaseous axial flows through linearly elastic tube and annulus micro-configurations. For steady flows, the leading-order effects of elasticity on the pressure distribution and mass-flux are obtained. For transient flow in a tube with small deformations, elastic effects are shown to be negligible in leading order due to compressibility. We then examine transient flows in annular configurations where the deformation is significant compared with the gap between the inner and outer cylinders defining the annulus. Both compressibility and elasticity are obtained as dominant terms interacting with viscosity. For a sudden flux impulse, the governing non-linear leading order diffusion equation is initially approximated by a porous-medium-equation of order 2.5 for the pressure square. However, as the fluid expand and the pressure decreases, the governing equation degenerates to a porous-medium-equation of order 2 for the pressure.

  4. Visualization of microvessels with in-house micro-angiography

    International Nuclear Information System (INIS)

    Chiku, Masaaki; Nishigami, Kazuhiro; Takeshita, Satoshi

    2005-01-01

    Although therapeutic angiogenesis improved critical limb ischemia in humans, microvessels promoted by therapeutic angiogenesis needed further improvement to be visualized well by conventional angiographic system, because of its limited spatial resolution of 200 μm. We have developed an in-house micro-angiographic system consisting of a high-voltage power X-ray source and a detecting system with high levels of spatial resolution and sensitivity. The in-house microvessel angiographic system demonstrated its ability to evaluate the function of microvessels in vivo, as well as to visualize them with higher precision than the conventional angiographic system. The findings of our study suggest that a novel micro-angiographic system may be useful in evaluating the efficacy of therapeutic angiogenesis in clinical settings. (author)

  5. Visual beam tube inspection at the TRIGA reactor Vienna

    International Nuclear Information System (INIS)

    Boeck, H.; Musilek, A.; Villa, M.

    2006-01-01

    Of the four TRIGA beam tubes two have been visually inspected in 1985. Prior to the inspection the reactor was shut down for 3 weeks. The fuel elements around the beam tubes were removed. Stainless steel dummy elements were inserted in the fuel positions to shield the core radiation. The active part of the Fast Rabbit Tube was removed into the beam tube loading device and transferred to an interim storage: Front dose rate was ∼ 50 mSv/h. Generally the beam tube was very clean, after the last inspection about 30 years ago. A1 cm cut was observed at the beam tube front end. A rigid endoscope was used to check the beam tube's inner surface using a 90 degree deflection objective and photo- and video equipment. The direct dose rate in front of the beam tube was about 30 mSv/h. The beam tube was vacuum cleaned. A corroded shielding tank containing boric acid has leaked. A wooden collimator partially disintegrating due to extreme temperature was removed from beam tube D. Documentation of the inspection for visible defects is produced for later comparison

  6. Buckling analysis of micro- and nano-rods/tubes based on nonlocal Timoshenko beam theory

    International Nuclear Information System (INIS)

    Wang, C M; Zhang, Y Y; Ramesh, Sai Sudha; Kitipornchai, S

    2006-01-01

    This paper is concerned with the elastic buckling analysis of micro- and nano-rods/tubes based on Eringen's nonlocal elasticity theory and the Timoshenko beam theory. In the former theory, the small scale effect is taken into consideration while the effect of transverse shear deformation is accounted for in the latter theory. The governing equations and the boundary conditions are derived using the principle of virtual work. Explicit expressions for the critical buckling loads are derived for axially loaded rods/tubes with various end conditions. These expressions account for a better representation of the buckling behaviour of micro- and nano-rods/tubes where small scale effect and transverse shear deformation effect are significant. By comparing it with the classical beam theories, the sensitivity of the small scale effect on the buckling loads may be observed

  7. Erythorbic acid promoted formation of CdS QDs in a tube-in-tube micro-channel reactor

    Energy Technology Data Exchange (ETDEWEB)

    Liang, Yan; Tan, Jiawei; Wang, Jiexin; Chen, Jianfeng [State Key Laboratory of Organic–Inorganic Composites, Beijing University of Chemical Technology, Beijing 100029 (China); Research Center of the Ministry of Education for High Gravity Engineering and Technology, Beijing University of Chemical Technology, Beijing 100029 (China); Sun, Baochang, E-mail: sunbc@mail.buct.edu.cn [State Key Laboratory of Organic–Inorganic Composites, Beijing University of Chemical Technology, Beijing 100029 (China); Research Center of the Ministry of Education for High Gravity Engineering and Technology, Beijing University of Chemical Technology, Beijing 100029 (China); Shao, Lei, E-mail: shaol@mail.buct.edu.cn [State Key Laboratory of Organic–Inorganic Composites, Beijing University of Chemical Technology, Beijing 100029 (China); Research Center of the Ministry of Education for High Gravity Engineering and Technology, Beijing University of Chemical Technology, Beijing 100029 (China)

    2014-12-15

    Erythorbic acid assistant synthesis of CdS quantum dots (QDs) was conducted by homogeneous mixing of two continuous liquids in a high-throughput microporous tube-in-tube micro-channel reactor (MTMCR) at room temperature. The effects of the micropore size of the MTMCR, liquid flow rate, mixing time and reactant concentration on the size and size distribution of CdS QDs were investigated. It was found that the size and size distribution of CdS QDs could be tuned in the MTMCR. A combination of erythorbic acid promoted formation technique with the MTMCR may be a promising pathway for controllable mass production of QDs.

  8. Utilization of Stop-flow Micro-tubing Reactors for the Development of Organic Transformations.

    Science.gov (United States)

    Toh, Ren Wei; Li, Jie Sheng; Wu, Jie

    2018-01-04

    A new reaction screening technology for organic synthesis was recently demonstrated by combining elements from both continuous micro-flow and conventional batch reactors, coined stop-flow micro-tubing (SFMT) reactors. In SFMT, chemical reactions that require high pressure can be screened in parallel through a safer and convenient way. Cross-contamination, which is a common problem in reaction screening for continuous flow reactors, is avoided in SFMT. Moreover, the commercially available light-permeable micro-tubing can be incorporated into SFMT, serving as an excellent choice for light-mediated reactions due to a more effective uniform light exposure, compared to batch reactors. Overall, the SFMT reactor system is similar to continuous flow reactors and more superior than batch reactors for reactions that incorporate gas reagents and/or require light-illumination, which enables a simple but highly efficient reaction screening system. Furthermore, any successfully developed reaction in the SFMT reactor system can be conveniently translated to continuous-flow synthesis for large scale production.

  9. Visualization of boiling two-phase flow in a small diameter tube using neutron radiography

    International Nuclear Information System (INIS)

    Hibiki, Takashi; Mishima, Kaichiro; Yoneda, Kenji; Fujine, Shigenori; Kanda, Keiji; Nishihara, Hideaki

    1991-01-01

    The characteristics of boiling two-phase flow in a small diameter tube are very important for cooling the blanket in a nuclear fusion reactor or a high performance electronic device. For all these subjects, it is necessary to visualize the flow in a tube as a starting point of the study. However, when an optical method cannot be used for the visualization, it is expected that neutron radiography is useful. In this study, the feasibility of visualization of boiling two-phase flow in a small diameter tube was investigated by using various facilities of neutron radiography as the first step. The basic concept of neutron radiography and the block diagram of a neutron television system are shown. The neutron beam attenuated by water in the test section makes a scintillator emit visible light, and produces an image of two-phase flow, which is taken with a TV camera. Thus the image can be observed at real time. Three kinds of the experiments were performed with the facilities of KUR, NSRR and JRR-3. The experimental methods and the results are reported. The images obtained were sufficiently clear. (K.I.)

  10. Oil flow in the oil well tube annulus of vertical bearing assemblies (leakage)

    International Nuclear Information System (INIS)

    Piao, Yinghu

    1997-01-01

    A numerical simulation and experimental flow visualization study was conducted to better understand oil well leakage, particularly in the annular clearance space surrounding the oil well tube. A test rig was developed to simulate the bearing's oil well tube annulus. A major feature of this rig was to allow visual access to the annular clearance space and to the region beneath the rotating runner where strong secondary flow effects are known to exist. The main method for tracing the secondary flow pathlines was a light sheet visualization technique using micro air bubbles as the tracer. The effect of runner speed on the pathlines was studied. The velocity of the oil flow was measured experimentally and the results were compared with numerical data. A numerical technique was developed to trace the micro air bubbles in the oil flow field using a three dimensional CFD code for laminar, axisymmetric flow with a free surface. The buoyancy effects of gravitational and centrifugal forces were considered when determining the pathline of air bubbles. Bubble size, oil viscosity and runner speed were some of the parameters that affect the path of the air bubbles

  11. Visualization of two-phase gas-liquid flow regimes in horizontal and slightly-inclined circular tubes

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Livia Alves [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil); Nuclear Engineering Institute (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil)], E-mail: livia@lasme.coppe.ufrj.br; Cunha Filho, Jurandyr; Su, Jian [Coordenacao dos Programas de Pos-Graduacao de Engenharia (COPPE/UFRJ), RJ (Brazil). Nuclear Engineering Program], Emails: cunhafilho@lasme.coppe.ufrj.br, sujian@lasme.coppe.ufrj.br; Faccini, Jose Luiz Horacio [Nuclear Engineering Institute (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil)], E-mail: faccini@ien.gov.br

    2010-07-01

    In this paper a flow visualization study was performed for two-phase gas-liquid flow in horizontal and slightly inclined tubes. The test section consists of a 2.54 cm inner diameter stainless steel circular tube, followed by a transparent acrylic tube with the same inner diameter. The working fluids were air and water, with liquid superficial velocities ranging from 0:11 to 3:28 m/s and gas superficial velocities ranging from 0:27 to 5:48 m/s. Flow visualization was executed for upward flow at 5 deg and 10 deg and downward flow at 2:5 deg, 5 deg and 10 deg, as well as for horizontal flow. The visualization technique consists of a high-speed digital camera that records images at rates of 125 and 250 frames per second of a concurrent air-water mixture through a transparent part of the tube. From the obtained images, the flow regimes were identified (except for annular flow), observing the effect of inclination angles on flow regime transition boundaries. Finally, the experimental results were compared with empirical and theoretical flow pattern maps available in literature. (author)

  12. Development of Micro-welding Technology of Cladding Tube with Temperature Sensor for Nuclear Fuel Irradiation Test

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Soo Sung; Lee, C. Y.; Kim, W. K.; Lee, J. W.; Lee, D. Y

    2006-01-15

    Laser welding technology is widely used to fabricate some products of nuclear fuel in the nuclear industry. Especially, micro-laser welding is one of the key technology to be developed to fabricate precise products of fuel irradiation test. We have to secure laser welding technology to perform various instrumentations for fuel irradiation test. The instrumented fuel irradiation test at a research reactor is needed to evaluate the performance of the developed nuclear fuel. The fuel elements can be designed to measure the center line temperature of fuel pellets during the irradiation test by using temperature sensor. The thermal sensor was composed of thermocouple and sensor sheath. Micro-laser welding technology was adopted to seal between seal tube and sensor sheath with thickness of 0.15mm. The soundness of weld area has to be confirmed to prevent fission gas of the fuel from leaking out of the element during the fuel irradiation test. In this study, fundamental data for micro-laser welding technology was proposed to seal temperature sensor sheath of the instrumented fuel element. And, micro-laser welding for dissimilar metals between sensor sheath and seal tube was characterized by investigating welding conditions. Moreover, the micro-laser welding technology is closely related to advanced industry. It is expected that the laser material processing technology will be adopted to various applications in the industry.

  13. Heat transfer during condensation of HFC-134a and R-404A inside of a horizontal smooth and micro-fin tube

    Energy Technology Data Exchange (ETDEWEB)

    Sapali, S N [Govt. College of Engineering, Department of Mechanical Engineering, Shivaji Nagar, Pune, Maharashtra 411 005 (India); Patil, Pradeep A [AISSMS College of Engineering, Pune University, Mechanical Engineering Department, Kennedy Road, Near R.T.O., Pune, Maharashtra 411 001 (India)

    2010-11-15

    In recent small and medium capacity refrigeration systems, the condenser tubes are provided with micro-fins from inside. The vapour refrigerant at the compressor outlet and the condenser inlet is in superheat state. As it advances in the condenser it is in two phases and at the outlet it is in sub cooled liquid. The heat transfer coefficient (HTC) during condensation of HFC-134a and R-404A in a smooth (8.56 mm ID) and micro-fin tubes (8.96 mm ID) are experimentally investigated. Different from previous studies, the present experiments are performed for various condensing temperatures, with superheating and sub cooling and using hermetically sealed compressor. The test runs are done at average saturated condensing temperatures ranging from 35 C to 60 C. The mass fluxes are between 90 and 800 kg m{sup -2} s{sup -1}. The experimental results indicate that the average HTC increases with mass flux but decreases with increasing condensing temperature for both smooth and micro-fin tubes. The average condensation HTCs of HFC-134a and R-404A for the micro-fin tubes were 1.5-2.5 and 1.3-2 times larger than that in smooth tube respectively. The HTCs for R-404A are less than that of HFC-134a. New correlations based on the data gathered during the experimentation for predicting condensation HTCs are proposed for wide range of operating conditions. (author)

  14. Experimental Study on Flow Boiling of Carbon Dioxide in a Horizontal Microfin Tube

    Science.gov (United States)

    Kuwahara, Ken; Ikeda, Soshi; Koyama, Shigeru

    This paper deals with the experimental study on flow boiling heat transfer of carbon dioxide in a micro-fin tube. The geometrical parameters of micro-fin tube used in this study are 6.07 mm in outer diameter, 5.24 mm in average inner diameter, 0.256 mm in fin height, 20.4 in helix angle, 52 in number of grooves and 2.35 in area expansion ratio. Flow patterns and heat transfer coefficients were measured at 3-5 MPa in pressure, 300-540 kg/(m2s) in mass velocity and -5 to 15 °C in CO2 temperature. Flow patterns of wavy flow, slug flow and annular flow were observed. The measured heat transfer coefficients of micro-fin tube were 10-40 kW/(m2K). Heat transfer coefficients were strongly influenced by pressure.

  15. Tracking and visualization of space-time activities for a micro-scale flu transmission study.

    Science.gov (United States)

    Qi, Feng; Du, Fei

    2013-02-07

    Infectious diseases pose increasing threats to public health with increasing population density and more and more sophisticated social networks. While efforts continue in studying the large scale dissemination of contagious diseases, individual-based activity and behaviour study benefits not only disease transmission modelling but also the control, containment, and prevention decision making at the local scale. The potential for using tracking technologies to capture detailed space-time trajectories and model individual behaviour is increasing rapidly, as technological advances enable the manufacture of small, lightweight, highly sensitive, and affordable receivers and the routine use of location-aware devices has become widespread (e.g., smart cellular phones). The use of low-cost tracking devices in medical research has also been proved effective by more and more studies. This study describes the use of tracking devices to collect data of space-time trajectories and the spatiotemporal processing of such data to facilitate micro-scale flu transmission study. We also reports preliminary findings on activity patterns related to chances of influenza infection in a pilot study. Specifically, this study employed A-GPS tracking devices to collect data on a university campus. Spatiotemporal processing was conducted for data cleaning and segmentation. Processed data was validated with traditional activity diaries. The A-GPS data set was then used for visual explorations including density surface visualization and connection analysis to examine space-time activity patterns in relation to chances of influenza infection. When compared to diary data, the segmented tracking data demonstrated to be an effective alternative and showed greater accuracies in time as well as the details of routes taken by participants. A comparison of space-time activity patterns between participants who caught seasonal influenza and those who did not revealed interesting patterns. This study

  16. Vibrating makes for better seeing: from the fly's micro eye movements to hyperacute visual sensors

    Directory of Open Access Journals (Sweden)

    Stéphane eViollet

    2014-04-01

    Full Text Available Active vision means that visual perception not only depends closely on the subject's own movements, but that these movements actually contribute to the visual perceptual processes. Vertebrates' and invertebrates' eye movements are probably part of an active visual process, but their exact role still remains to be determined. In this paper, studies on the retinal micro-movements occurring in the compound eye of the fly are reviewed. Several authors have located and identified the muscles involved in these small retinal movements. Others have established that these retinal micro-movements occur in walking and flying flies, but their exact functional role still remains to be determined. Many robotic studies have been performed in which animals' (flies' and spiders' miniature eye movements have been modelled, simulated and even implemented mechanically. Several robotic platforms have been endowed with artificial visual sensors performing periodic micro-scanning movements. Artificial eyes performing these active retinal micro-movements have some extremely interesting properties, such as hyperacuity and the ability to detect very slow movements (motion hyperacuity. The fundamental role of miniature eye movements still remains to be described in detail, but several studies on natural and artificial eyes have advanced considerably toward this goal.

  17. Long-range particle manipulation in a micro-capillary tube by using a flexural acoustic wave

    International Nuclear Information System (INIS)

    Kim, Eun-Sun; Kim, Nari; Kim, Young-Ho; Lee, Kwang-Jo; Hwang, In-Kag

    2010-01-01

    We report a one-dimensional manipulation of dry Ag particles in micro-capillary tube by using a flexural acoustic wave propagating along the tube. The capillary tube is used as a mechanical guide for both the particles and the acoustic wave, resulting in an effective interaction between them over a long range of 14 cm in length. Linear transport and local trapping of the particles are demonstrated by the excitation of traveling and standing acoustic waves, respectively. The mechanisms for the particle movements are qualitatively explained by frictional forces between the particles and the inner wall of the capillary tube.

  18. Dissimilar metal study on C44300 tube to AA7075 -T651 tube plate with and without thread by FWTPET process

    Energy Technology Data Exchange (ETDEWEB)

    Radhakrishnan, E.; Kumaraswamidhas, L. A. [Indian Institute of Technology (ISM), Jharkhand (India); Muruganandam, D. [Sri Sairam Engineering College, Tamil Nadu (India); Kumaran, S. Senthil [RVS School of Engineering and Technology, Tamilnadu, (India)

    2017-05-15

    Friction welding has vital industrial role in fabricating automobiles, aerospace, ship building, heat exchangers using similar, dissimilar and bi-metal of ferrous and non-ferrous metals at mass production level. In this study, admiralty brass C44300 tube and aluminium alloy AA7075 -T651, 6 mm thick tube plate were identified as base metals. Different joint surface area profile of with and without thread of different pitch values was chosen to study the mechanical properties and micro structures of these two base metals. 0.1 mm clearance was maintained between the AA7075-T651 tube plate and C44300 tube outer diameter to make friction welding. Taguchi’s L16 orthogonal array techniques were adopted for identifying the most significant ranking process parameters. Analysis of variance (ANOVA) has been used to analyze the input parameter contribution in terms of percentage. Genetic algorithm (GA) was used to access the suitable input parameter value to obtain effective joint strength in terms of hardness, compressive strength and microstructure formation in the interface of the joint. A Compression test (CT) was conducted to evaluate the level of compressive strength of the joint. Threaded profile pair with higher pitch value proved high compressive strength over unthreaded pair. Micro structure for base metal C44300 tube and AA7075-T651 tube plate, Heat affected zone (HAZ) and Weld zone (WZ) of the joint has been studied. Hardness of base metals, HAZ and WZ was measured by micro Vickers hardness tester and the observation shows that hardness at joint interface has been found to be higher in all pairs.

  19. Study of thermal performance of capillary micro tubes integrated into the building sandwich element made of high performance concrete

    DEFF Research Database (Denmark)

    Mikeska, Tomas; Svendsen, Svend

    2013-01-01

    The thermal performance of radiant heating and cooling systems (RHCS) composed of capillary micro tubes (CMT) integrated into the inner plate of sandwich elements made of high performance concrete (HPC) was investigated in the article. Temperature distribution in HPC elements around integrated CM...... and cooling purposes of future low energy buildings. The investigations were conceived as a low temperature concept, where the difference between the temperature of circulating fluid and air in the room was kept in range of 1–4 °C.......The thermal performance of radiant heating and cooling systems (RHCS) composed of capillary micro tubes (CMT) integrated into the inner plate of sandwich elements made of high performance concrete (HPC) was investigated in the article. Temperature distribution in HPC elements around integrated CMT...... HPC layer covering the CMT. This paper shows that CMT integrated into the thin plate of sandwich element made of HPC can supply the energy needed for heating (cooling) and at the same time create the comfortable and healthy environment for the occupants. This solution is very suitable for heating...

  20. A novel method for calculating the dynamic capillary force and correcting the pressure error in micro-tube experiment.

    Science.gov (United States)

    Wang, Shuoliang; Liu, Pengcheng; Zhao, Hui; Zhang, Yuan

    2017-11-29

    Micro-tube experiment has been implemented to understand the mechanisms of governing microcosmic fluid percolation and is extensively used in both fields of micro electromechanical engineering and petroleum engineering. The measured pressure difference across the microtube is not equal to the actual pressure difference across the microtube. Taking into account the additional pressure losses between the outlet of the micro tube and the outlet of the entire setup, we propose a new method for predicting the dynamic capillary pressure using the Level-set method. We first demonstrate it is a reliable method for describing microscopic flow by comparing the micro-model flow-test results against the predicted results using the Level-set method. In the proposed approach, Level-set method is applied to predict the pressure distribution along the microtube when the fluids flow along the microtube at a given flow rate; the microtube used in the calculation has the same size as the one used in the experiment. From the simulation results, the pressure difference across a curved interface (i.e., dynamic capillary pressure) can be directly obtained. We also show that dynamic capillary force should be properly evaluated in the micro-tube experiment in order to obtain the actual pressure difference across the microtube.

  1. Failure analysis of a boiler tube in USC coal power plant

    Energy Technology Data Exchange (ETDEWEB)

    Lee, N.H.; Kim, S.; Choe, B.H.; Yoon, K.B.; Kwon, D.I. [Kangnung National University, Kangnung (Republic of Korea)

    2009-10-15

    This paper presents failure analysis of final superheater tube in ultra-supercritical (USC) coal power plant. Visual inspection was performed to find out the characteristics of fracture of the as-received material. And the micro-structural changes such as grain growth and carbide coarsening was examined by scanning electron microscope. Detailed microscopic studies were made to find out the behavior of the scale exfoliation on the waterside of tubes. From those investigations, the creep rupture may be caused by the softened structure induced by carbide coarsening and accelerated by the metal temperature increase by the impediment of heat transfer due to voids.

  2. Isolation of Microarray-Grade Total RNA, MicroRNA, and DNA from a Single PAXgene Blood RNA Tube

    DEFF Research Database (Denmark)

    Kruhøffer, Mogens; Andersen, Lars Dyrskjøt; Voss, Thorsten

    2007-01-01

    We have developed a procedure for isolation of microRNA and genomic DNA in addition to total RNA from whole blood stabilized in PAXgene Blood RNA tubes. The procedure is based on automatic extraction on a BioRobot MDx and includes isolation of DNA from a fraction of the stabilized blood...... and recovery of small RNA species that are otherwise lost. The procedure presented here is suitable for large-scale experiments and is amenable to further automation. Procured total RNA and DNA was tested using Affymetrix Expression and single-nucleotide polymorphism GeneChips, respectively, and isolated micro......RNA was tested using spotted locked nucleic acid-based microarrays. We conclude that the yield and quality of total RNA, microRNA, and DNA from a single PAXgene blood RNA tube is sufficient for downstream microarray analysis....

  3. Design and development of micro pulse lidar for cloud and aerosol studies

    Science.gov (United States)

    Dubey, P. K.; Arya, B. C.; Ahammed, Y. Nazeer; Kumar, Arun; Kulkarni, P. S.; Jain, S. L.

    2008-12-01

    A micro pulse lidar (MPL) has been indigenously designed and developed at the National Physical Laboratory, New Delhi using a 532 nm, 500 pico second pulsed laser having average power of 50mW (at 7.5 KHz PRR). Photon counting technique has been incorporated using the conventional optics, multichannel scaler (Stanford Research Systems SR430) and high sensitive photomultiplier tube. The sensitivity, range and bin etc are computer controlled in the present system. The interfacing between MPL and computer has been achieved by serial (RS232) and parallel printer port. The necessary software and graphical user interface has been developed using visual basic. In addition to this the telescope cover status sensing circuit has been incorporated to avoid conflict between dark count and background acquisition. The micro pulse lidar will be used for the aerosol, boundary layer and the cloud studies at a bin resolution of 6 meters. In the present communication the details of the system and preliminary results will be presented.

  4. Experimental studies on the evaporative heat transfer and pressure drop of CO{sub 2} and CO{sub 2}/propane mixtures flowing upward in smooth and micro-fin tubes with outer diameter of 5 mm for an inclination angle of 45

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Jin Min; Kim, Min Soo [School of Mechanical and Aerospace Engineering, Seoul National University, Seoul 151-744 (Korea); Kim, Yong Jin [School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA 30332 (United States)

    2010-08-15

    Heat transfer characteristics show different tendency according to the tube orientations such as horizontal, vertical, and inclined positions. In this study, evaporative heat transfer characteristics and pressure drop of CO{sub 2} and CO{sub 2}/propane mixtures flowing upward are investigated in inclined smooth and micro-fin tubes. Smooth and micro-fin tubes with outer diameter of 5 mm and length of 1.44 m with inclination angle of 45 were chosen as test tubes. Average inner diameters of test tubes are 4.0 mm (smooth tube) and 4.13 mm (micro-fin tube). The tests were conducted at mass fluxes from 212 to 656 kg/m{sup 2} s, saturation temperatures from -10 to 30 C and heat fluxes from 15 to 60 kW/m{sup 2} for CO{sub 2}. In addition, for CO{sub 2}/propane mixtures, the test was carried out at inlet temperatures from -10 to 30 C for several compositions (75/25, 50/50, 25/75 wt%) with the same mass fluxes, heat fluxes applied for CO{sub 2}. Heat transfer coefficients in inclined tube are approximately 1.8-3 times higher than those in horizontal tube and the average pressure drop of inclined tube exists between that of horizontal and vertical tubes. (author)

  5. Experimental and numerical studies of choked flow through adiabatic and diabatic capillary tubes

    International Nuclear Information System (INIS)

    Deodhar, Subodh D.; Kothadia, Hardik B.; Iyer, K.N.; Prabhu, S.V.

    2015-01-01

    Capillary tubes are extensively used in several cooling applications like refrigeration, electronic cooling etc. Local pressure variation in adiabatic straight capillary tube (mini channel) is studied experimentally and numerically with R134a as the working fluid. Experiments are performed on two straight capillary tubes. It is found that the diameter is the most sensitive design parameter of the capillary tube. Experiments are performed on five helically coiled capillary tubes to quantify the effect of pitch and curvature of helically coiled capillary tube on the pressure drop. Non dimensionalized factor to account coiling of capillary tube is derived to calculate mass flow rate in helically coiled capillary tubes. Flow visualization in adiabatic capillary tube confirms the bubbly nature of two phase flow. Numerical and experimental investigations in diabatic capillary tube suggest that the use of positive displacement pump and choking at the exit of the channel ensures flow stability. - Highlights: • Model is developed to design capillary tube in adiabatic and diabatic condition. • Effect of coil curvature on pressure drop is studied experimentally. • Correlation is developed to predict mass flow rate in helical capillary tubes. • Flow visualization is carried out to check the type of two phase flow. • Effect of choked flow on diabatic capillary tubes is studied experimentally.

  6. Active infrared thermography for visualizing subsurface micro voids in an epoxy molding compound

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Ji Yeol [Test and Package Center, Samsung Electronics, Asan(Korea, Republic of); Hwang, Soon Kyu; Choi, Jae Mook; Sohn, Hoon [Dept. of Civil and Environmental Engineering, Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of)

    2017-04-15

    This paper presents an automated subsurface micro void detection technique based on pulsed infrared thermography for inspecting epoxy molding compounds (EMC) used in electronic device packaging. Subsurface micro voids are first detected and visualized by extracting a lock-in amplitude image from raw thermal images. Binary imaging follows to achieve better visualization of subsurface micro voids. A median filter is then applied for removing sparse noise components. The performance of the proposed technique is tested using 36 EMC samples, which have subsurface (below 150 μm ~ 300 μm from the inspection surface) micro voids (150 μm ~ 300 μm in diameter). The experimental results show that the subsurface micro voids can be successfully detected without causing any damage to the EMC samples, making it suitable for automated online inspection.

  7. Ferruleless coupled-cavity traveling-wave tube cold-test characteristics simulated with micro-SOS

    Science.gov (United States)

    Schroeder, Dana L.; Wilson, Jeffrey D.

    1993-01-01

    The three-dimensional, electromagnetic circuit analysis code, Micro-SOS, can be used to reduce expensive and time consuming experimental 'cold-testing' of traveling-wave tube (TWT) circuits. The frequency-phase dispersion and beam interaction impedance characteristics of a ferruleless coupled-cavity traveling-wave tube slow-wave circuit were simulated using the code. Computer results agree closely with experimental data. Variations in the cavity geometry dimensions of period length and gap-to-period ratio were modeled. These variations can be used in velocity taper designs to reduce the radiofrequency (RF) phase velocity in synchronism with the decelerating electron beam. Such circuit designs can result in enhanced TWT power and efficiency.

  8. Visualization and void fraction measurement of decompressed boiling flow in a capillary tube

    International Nuclear Information System (INIS)

    Asano, H.; Murakawa, H.; Takenaka, N.; Takiguchi, K.; Okamoto, M.; Tsuchiya, T.; Kitaide, Y.; Maruyama, N.

    2011-01-01

    A capillary tube is often used as a throttle for a refrigerating cycle. Subcooled refrigerant usually flows from a condenser into the capillary tube. Then, the refrigerant is decompressed along the capillary tube. When the static pressure falls below the saturation pressure for the liquid temperature, spontaneous boiling occurs. A vapor-liquid two-phase mixture is discharged from the tube. In designing a capillary tube, it is necessary to calculate the flow rate for given boundary conditions on pressure and temperature at the inlet and exit. Since total pressure loss is dominated by frictional and acceleration losses during two-phase flow, it is first necessary to specify the boiling inception point. However, there will be a delay in boiling inception during decompressed flow. This study aimed to clarify the boiling inception point and two-phase flow characteristics of refrigerant in a capillary tube. Refrigerant flows in a coiled copper capillary tube were visualized by neutron radiography. The one-dimensional distribution of volumetric average void fraction was measured from radiographs through image processing. From the void fraction distribution, the boiling inception point was determined. Moreover, a simplified CT method was successfully applied to a radiograph for cross-sectional measurements. The experimental results show the flow pattern transition from intermittent flow to annular flow that occurred at a void fraction of about 0.45.

  9. Visualization of cross-sectional flow structure during condensation of steam in a slightly inclined horizontal tube

    Energy Technology Data Exchange (ETDEWEB)

    Puseya, Andree; Kim, H. [Kyung Hee University, Yongin (Korea, Republic of); Kwon, T. S. [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-10-15

    These flow characteristics called flow patterns still depend on a proper visualization technique in order to identify such local distribution. These proper distributions will have a dependence on the inclination of the tube as well, as it was demonstrated by Lips and Mayer. This work is focused on presenting an experimental investigation to visualize the cross sectional two-phase flow structure for condensation of steam in a horizontal tube and identify the liquid-gas interface using the axial-viewing technique. This innovative technique developed by Hewitt and more recently used in visualization works by Badie, permits the achievement to identify those systems in the area of interest by looking directly into the two-phase flow system during condensation of steam inside a pipe with technology such a high speed camera. An experimental work to visualize and locate the liquid-gas interface for steam condensation in horizontal tubes with slightly inclination was developed on this research The experimental results shows that the axial viewing technique works well with condensation phenomena and can be used for further developments in the field such as determination of liquid film geometry and calculation of void fraction.

  10. The effect of bubble acceleration on the liquid film thickness in micro tubes

    Energy Technology Data Exchange (ETDEWEB)

    Han, Youngbae, E-mail: bhan@feslab.t.u-tokyo.ac.j [Department of Mechanical Engineering, University of Tokyo, Hongo 7-3-1, Bunkyo-ku, Tokyo 113-8656 (Japan); Shikazono, Naoki, E-mail: shika@feslab.t.u-tokyo.ac.j [Department of Mechanical Engineering, University of Tokyo, Hongo 7-3-1, Bunkyo-ku, Tokyo 113-8656 (Japan)

    2010-08-15

    Liquid film thickness is an important parameter for predicting boiling heat transfer in micro tubes. In the previous study (), liquid film thickness under the steady condition was investigated and an empirical correlation for the initial liquid film thickness based on capillary number, Reynolds number and Weber number was proposed. However, under flow boiling conditions, bubble velocity is not constant but accelerated due to evaporation. It is necessary to consider this bubble acceleration effect on the liquid film thickness, since it affects viscous, surface tension and inertia forces in the momentum equation. In addition, viscous boundary layer develops, and it may also affect the liquid film thickness. In the present study, the effect of bubble acceleration is investigated. Laser focus displacement meter is used to measure the liquid film thickness. Ethanol, water and FC-40 are used as working fluids. Circular tubes with three different inner diameters, D = 0.5, 0.7 and 1.0 mm, are used. The increase of liquid film thickness with capillary number is restricted by the bubble acceleration. Finally, an empirical correlation is proposed for the liquid film thickness of accelerated flows in terms of capillary number and Bond number based on the bubble acceleration.

  11. The effect of bubble acceleration on the liquid film thickness in micro tubes

    International Nuclear Information System (INIS)

    Han, Youngbae; Shikazono, Naoki

    2010-01-01

    Liquid film thickness is an important parameter for predicting boiling heat transfer in micro tubes. In the previous study (), liquid film thickness under the steady condition was investigated and an empirical correlation for the initial liquid film thickness based on capillary number, Reynolds number and Weber number was proposed. However, under flow boiling conditions, bubble velocity is not constant but accelerated due to evaporation. It is necessary to consider this bubble acceleration effect on the liquid film thickness, since it affects viscous, surface tension and inertia forces in the momentum equation. In addition, viscous boundary layer develops, and it may also affect the liquid film thickness. In the present study, the effect of bubble acceleration is investigated. Laser focus displacement meter is used to measure the liquid film thickness. Ethanol, water and FC-40 are used as working fluids. Circular tubes with three different inner diameters, D = 0.5, 0.7 and 1.0 mm, are used. The increase of liquid film thickness with capillary number is restricted by the bubble acceleration. Finally, an empirical correlation is proposed for the liquid film thickness of accelerated flows in terms of capillary number and Bond number based on the bubble acceleration.

  12. Vibrating makes for better seeing: from the fly's micro eye movements to hyperacute visual sensors

    OpenAIRE

    Stéphane eViollet

    2014-01-01

    Active vision means that visual perception not only depends closely on the subject's own movements, but that these movements actually contribute to the visual perceptual processes. Vertebrates' and invertebrates' eye movements are probably part of an active visual process, but their exact role still remains to be determined. In this paper, studies on the retinal micro-movements occurring in the compound eye of the fly are reviewed. Several authors have located and identified the muscles invo...

  13. Enhanced Evaporation and Condensation in Tubes

    Science.gov (United States)

    Honda, Hiroshi

    A state-of-the-art review of enhanced evaporation and condensation in horizontal microfin tubes and micro-channels that are used for air-conditioning and refrigeration applications is presented. The review covers the effects of flow pattern and geometrical parameters of the tubes on the heat transfer performance. Attention is paid to the effect of surface tension which leads to enhanced evaporation and condensation in the microfin tubes and micro-channels. A review of prior efforts to develop empirical correlations of the heat transfer coefficient and theoretical models for evaporation and condensation in the horizontal microfin tubes and micro-channels is also presented.

  14. Comparison of automatic and visual methods used for image segmentation in Endodontics: a microCT study.

    Science.gov (United States)

    Queiroz, Polyane Mazucatto; Rovaris, Karla; Santaella, Gustavo Machado; Haiter-Neto, Francisco; Freitas, Deborah Queiroz

    2017-01-01

    To calculate root canal volume and surface area in microCT images, an image segmentation by selecting threshold values is required, which can be determined by visual or automatic methods. Visual determination is influenced by the operator's visual acuity, while the automatic method is done entirely by computer algorithms. To compare between visual and automatic segmentation, and to determine the influence of the operator's visual acuity on the reproducibility of root canal volume and area measurements. Images from 31 extracted human anterior teeth were scanned with a μCT scanner. Three experienced examiners performed visual image segmentation, and threshold values were recorded. Automatic segmentation was done using the "Automatic Threshold Tool" available in the dedicated software provided by the scanner's manufacturer. Volume and area measurements were performed using the threshold values determined both visually and automatically. The paired Student's t-test showed no significant difference between visual and automatic segmentation methods regarding root canal volume measurements (p=0.93) and root canal surface (p=0.79). Although visual and automatic segmentation methods can be used to determine the threshold and calculate root canal volume and surface, the automatic method may be the most suitable for ensuring the reproducibility of threshold determination.

  15. The scope of detector Medipix2 in micro-radiography of biological samples

    Energy Technology Data Exchange (ETDEWEB)

    Dammer, J., E-mail: jiri.dammer@utef.cvut.cz [Institute of Experimental and Applied Physics, Czech Technical University in Prague, Horska 3a/22, CZ-12800 Prague 2 (Czech Republic); Weyda, F. [Biology Centre of the Academy of Sciences of the Czech Republic, Institute of Entomology, Branisovska 31, CZ-37005 Ceske Budejovice (Czech Republic); Faculty of Science, University of South Bohemia, Branisovska 31, CZ-37005 Ceske Budejovice (Czech Republic); Jakubek, J. [Institute of Experimental and Applied Physics, Czech Technical University in Prague, Horska 3a/22, CZ-12800 Prague 2 (Czech Republic); Skrabal, P. [Faculty of Biomedical Engineering, Czech Technical University in Prague, Nam. Sitna 3105, CZ-272 01 Kladno (Czech Republic); Sopko, V.; Vavrik, D. [Institute of Experimental and Applied Physics, Czech Technical University in Prague, Horska 3a/22, CZ-12800 Prague 2 (Czech Republic)

    2011-05-15

    We present our experimental setup devoted to high resolution X-ray micro-radiography that is suitable for imaging of small biological samples. The photon source is a FeinFocus micro-focus X-ray tube. The single photon counting pixel device Medipix2 serves as imaging area. Recently used imaging detectors as radiography films or scintillator detectors, cannot visualize required information about inner structure of scanned sample. Detectors Medipix2 do not suffer from so-called dark current noise and work in unlimited dynamic range. These features of detectors confer high quality and high contrast of final images. The radiographic imaging with detectors Medipix2 represents non-invasive and non-destructive method of investigation. Hereby, we demonstrate results of micro-radiographic study of internal structures of tiny biological samples. In addition to morphological and anatomical studies, we would like to present preliminary study of dynamic processes inside of organisms using micro-radiographic video-capturing.

  16. The scope of detector Medipix2 in micro-radiography of biological samples

    International Nuclear Information System (INIS)

    Dammer, J.; Weyda, F.; Jakubek, J.; Skrabal, P.; Sopko, V.; Vavrik, D.

    2011-01-01

    We present our experimental setup devoted to high resolution X-ray micro-radiography that is suitable for imaging of small biological samples. The photon source is a FeinFocus micro-focus X-ray tube. The single photon counting pixel device Medipix2 serves as imaging area. Recently used imaging detectors as radiography films or scintillator detectors, cannot visualize required information about inner structure of scanned sample. Detectors Medipix2 do not suffer from so-called dark current noise and work in unlimited dynamic range. These features of detectors confer high quality and high contrast of final images. The radiographic imaging with detectors Medipix2 represents non-invasive and non-destructive method of investigation. Hereby, we demonstrate results of micro-radiographic study of internal structures of tiny biological samples. In addition to morphological and anatomical studies, we would like to present preliminary study of dynamic processes inside of organisms using micro-radiographic video-capturing.

  17. Detecting and visualizing internal 3D oleoresin in agarwood by means of micro-computed tomography

    International Nuclear Information System (INIS)

    Khairiah Yazid; Roslan Yahya; Mat Rosol Awang

    2012-01-01

    Detection and analysis of oleoresin is particularly significant since the commercial value of agarwood is related to the quantity of oleoresins that are present. A modern technique of non-destructive may reach the interior region of the wood. Currently, tomographic image data in particular is most commonly visualized in three dimensions using volume rendering. The aim of this paper is to explore the potential of high resolution non-destructive 3D visualization technique, X-ray micro-computed tomography, as imaging tools to visualize micro-structure oleoresin in agarwood. Investigations involving desktop X-ray micro-tomography system on high grade agarwood sample, performed at the Centre of Tomography in Nuclear Malaysia, demonstrate the applicability of the method. Prior to experiments, a reference test was conducted to stimulate the attenuation of oleoresin in agarwood. Based on the experiment results, micro-CT imaging with voxel size 7.0 μm is capable to of detecting oleoresin and pores in agarwood. This imaging technique, although sophisticated can be used for standard development especially in grading of agarwood for commercial activities. (author)

  18. Coherent Synchrotron-Based Micro-Imaging Employed for Studies of Micro-Gap Formation in Dental Implants

    International Nuclear Information System (INIS)

    Rack, T.; Stiller, M.; Nelson, K.; Zabler, S.; Rack, A.; Riesemeier, H.; Cecilia, A.

    2011-01-01

    Biocompatible materials such as titanium are regularly applied in oral surgery. Titanium-based implants for the replacement of missing teeth demand a high mechanical precision in order to minimize micro-bacterial leakage, especially when two-piece concepts are used. Synchrotron-based hard x-ray radiography, unlike conventional laboratory radiography, allows high spatial resolution in combination with high contrast even when micro-sized features in such highly attenuating objects are visualized. Therefore, micro-gap formation at interfaces in two-piece dental implants with the sample under different mechanical loads can be studied. We show the existence of micro-gaps in implants with conical connections and study the mechanical behavior of the mating zone of conical implants during loading. The micro-gap is a potential source of implant failure, i.e., bacterial leakage, which can be a stimulus for an inflammatory process.

  19. Integrated visualization of multi-angle bioluminescence imaging and micro CT

    NARCIS (Netherlands)

    Kok, P.; Dijkstra, J.; Botha, C.P.; Post, F.H.; Kaijzel, E.; Que, I.; Löwik, C.W.G.M.; Reiber, J.H.C.; Lelieveldt, B.P.F.

    2007-01-01

    This paper explores new methods to visualize and fuse multi-2D bioluminescence imaging (BLI) data with structural imaging modalities such as micro CT and MR. A geometric, back-projection-based 3D reconstruction for superficial lesions from multi-2D BLI data is presented, enabling a coarse estimate

  20. Micro manometer and pitot tube for measuring the velocity distribution in a natural convection water stream between two vertical parallel plates (1961)

    International Nuclear Information System (INIS)

    Santon, L.; Vernier, Ph.

    1961-01-01

    For heat transfer studies in certain cases of cooling in swimming-pool type nuclear reactors, a knowledge of the distribution of the velocities between two heating elements is of prime importance. A Pitot tube and a micro-manometer have been developed for making these measurements on an experimental model. (authors) [fr

  1. Access NASA Satellite Global Precipitation Data Visualization on YouTube

    Science.gov (United States)

    Liu, Z.; Su, J.; Acker, J. G.; Huffman, G. J.; Vollmer, B.; Wei, J.; Meyer, D. J.

    2017-12-01

    Since the satellite era began, NASA has collected a large volume of Earth science observations for research and applications around the world. Satellite data at 12 NASA data centers can also be used for STEM activities such as disaster events, climate change, etc. However, accessing satellite data can be a daunting task for non-professional users such as teachers and students because of unfamiliarity of terminology, disciplines, data formats, data structures, computing resources, processing software, programing languages, etc. Over the years, many efforts have been developed to improve satellite data access, but barriers still exist for non-professionals. In this presentation, we will present our latest activity that uses the popular online video sharing web site, YouTube, to access visualization of global precipitation datasets at the NASA Goddard Earth Sciences (GES) Data and Information Services Center (DISC). With YouTube, users can access and visualize a large volume of satellite data without necessity to learn new software or download data. The dataset in this activity is the 3-hourly TRMM (Tropical Rainfall Measuring Mission) Multi-satellite Precipitation Analysis (TMPA). The video consists of over 50,000 data files collected since 1998 onwards, covering a zone between 50°N-S. The YouTube video will last 36 minutes for the entire dataset record (over 19 years). Since the time stamp is on each frame of the video, users can begin at any time by dragging the time progress bar. This precipitation animation will allow viewing precipitation events and processes (e.g., hurricanes, fronts, atmospheric rivers, etc.) on a global scale. The next plan is to develop a similar animation for the GPM (Global Precipitation Measurement) Integrated Multi-satellitE Retrievals for GPM (IMERG). The IMERG provides precipitation on a near-global (60°N-S) coverage at half-hourly time interval, showing more details on precipitation processes and development, compared to the 3

  2. Superparamagnetic iron oxide nanoparticle attachment on array of micro test tubes and microbeakers formed on p-type silicon substrate for biosensor applications

    Directory of Open Access Journals (Sweden)

    Raja Sufi

    2011-01-01

    Full Text Available Abstract A uniformly distributed array of micro test tubes and microbeakers is formed on a p-type silicon substrate with tunable cross-section and distance of separation by anodic etching of the silicon wafer in N, N-dimethylformamide and hydrofluoric acid, which essentially leads to the formation of macroporous silicon templates. A reasonable control over the dimensions of the structures could be achieved by tailoring the formation parameters, primarily the wafer resistivity. For a micro test tube, the cross-section (i.e., the pore size as well as the distance of separation between two adjacent test tubes (i.e., inter-pore distance is typically approximately 1 μm, whereas, for a microbeaker the pore size exceeds 1.5 μm and the inter-pore distance could be less than 100 nm. We successfully synthesized superparamagnetic iron oxide nanoparticles (SPIONs, with average particle size approximately 20 nm and attached them on the porous silicon chip surface as well as on the pore walls. Such SPION-coated arrays of micro test tubes and microbeakers are potential candidates for biosensors because of the biocompatibility of both silicon and SPIONs. As acquisition of data via microarray is an essential attribute of high throughput bio-sensing, the proposed nanostructured array may be a promising step in this direction.

  3. Experimental and visual study on flow patterns and pressure drops in U-tubes

    International Nuclear Information System (INIS)

    Da Silva Lima, J. R.

    2011-01-01

    In single- and two-phase flow heat exchangers (in particular 'coils'), besides the straight tubes there are also many singularities, in particular the 180° return bends (also called return bends or U-bends). However, contrary to the literature concerning pressure drops and heat transfer in straight tubes, where many experimental data and predicting methods are available, only a limited number of studies concerning U-bends can be found. Neither reliable experimental data nor proven prediction methods are available. Indeed, flow structure, pressure drop and heat transfer in U-bends are an old unresolved design problem in the heat transfer industry. Thus, the present study aims at providing further insight on two-phase pressure drops and flows patterns in U-bends. Based on a new type of U-bend test section, an extensive experimental study was conducted. The experimental campaign covered five test sections with three internal diameters (7.8, 10.8 and 13.4 mm), five bend diameters (24.8, 31.7, 38.1, 54.8 and 66.1 mm), tested for three orientations (horizontal, vertical upflow and vertical downflow), two fluids (R134a and R410A), two saturation temperatures (5 and 10 °C) and mass velocities ranging from 150 to 1000 kg s -1 m -2 . The flow pattern observations identified were stratified-wavy, slug-stratified-wavy, intermittent, annular, dryout and mist flows. The effects of the U-bend on the flow patterns were also observed. A total of 5655 pressure drop data were measured at seven different locations in the test section ( straight tubes and U-bend) providing a total of almost 40,000 data points. The straight tube data were first used to improve the actual two-phase straight tube model of Moreno-Quibén and Thome. This updated model was then used to developed a two-phase U-bend pressure drop model. Based on a comparison between experimental and predicted values, it is concluded that the new two-phase frictional pressure drop model for U-bends successfully

  4. Cavitational micro-particles: plasma formation mechanisms

    International Nuclear Information System (INIS)

    Bica, Ioan

    2005-01-01

    Cavitational micro-particles are a class to which the micro-spheres, the micro-tubes and the octopus-shaped micro-particles belong. The cavitational micro-particles (micro-spheres, micro-tubes and octopus-shaped micro-particles) at an environmental pressure. The micro-spheres, the micro-tubes and the ligaments of the octopus-shaped micro-particles are produced in the argon plasma and are formed of vapors with low values of the molar concentration in comparison with the molar density of the gas and vapor mixture, the first one on the unstable and the last two on the stable movement of the vapors. The ligaments of the octopus-shaped micro-particles are open at the top for well-chosen values of the sub-cooling of the vapor and gas cylinders. The nitrogen in the air favors the formation of pores in the wall of the micro-spheres. In this paper we present the cavitational micro-particles, their production in the plasma and some mechanisms for their formation in the plasma. (author)

  5. Study of Anterior Chamber Aqueous Tube Shunt by Fourier-Domain Optical Coherence Tomography

    Directory of Open Access Journals (Sweden)

    Chunhui Jiang

    2012-01-01

    Full Text Available Purpose. This cross-sectional, observational study used Fourier-domain optical coherence tomography (OCT to examine the position, patency, and the interior entrance site of anterior chamber (AC aqueous tube shunts. Methods. The OCT, slitlamp biomicroscopy, and gonioscopy findings of 23 eyes of 18 patients with AC shunts were collected and compared. Results. OCT images demonstrated the shunt position and patency in all 23 eyes, and the details of the AC entrance in 16 eyes. The position of the tube varied, with the majority (14/23 on the surface of the iris. The exact position of the AC entrance relative to Schwalbe’s line (SL could be determined in 9 eyes (posterior to SL in 7 eyes, anterior in 2 eyes. At the AC entrance, growth of fibrous scar tissue was present between the tube and the corneal endothelium in all 16 eyes in which the entrance could be clearly visualized. It’s a new finding that could not be visualized by slitlamp examination or lower resolution OCT. Conclusion. Compared to slitlamp examination, Fourier-domain OCT of AC tube shunts provided more detailed anatomic information regarding the insertion level relative to SL, scar tissue between the tube and the corneal endothelium, and patency of the tube opening.

  6. Experimental comparison and visualization of in-tube continuous and pulsating flow boiling

    DEFF Research Database (Denmark)

    Kærn, Martin Ryhl; Markussen, Wiebke Brix; Meyer, Knud Erik

    2018-01-01

    This experimental study investigated the application of fluid flow pulsations for in-tube flow boiling heat transfer enhancement in an 8 mm smooth round tube made of copper. The fluid flow pulsations were introduced by a flow modulating expansion device and were compared with continuous flow...... cycle time (7 s) reduced the time-averaged heat transfer coefficients by 1.8% and 2.3% for the low and high subcooling, respectively, due to significant dry-out when the flow-modulating expansion valve was closed. Furthermore, the flow pulsations were visualized by high-speed camera to assist...... generated by a stepper-motor expansion valve in terms of the time-averaged heat transfer coefficient. The cycle time ranged from 1 s to 7 s for the pulsations, the time-averaged refrigerant mass flux ranged from 50 kg m−2 s−1 to 194 kg m−2 s−1 and the time-averaged heat flux ranged from 1.1 kW m−2 to 30.6 k...

  7. Failure evaluation on a high-strength alloy SA213-T91 super heater tube of a power generation

    Energy Technology Data Exchange (ETDEWEB)

    Ahmad, J.; Purbolaksono, J.; Beng, L.C.; Ahmad, A. [University of Tenaga Nas, Kajang (Malaysia). Dept. of Mechanical Engineering

    2010-07-01

    This article presents failure investigation on a high-strength alloy SA213-T91 superheater tube. This failure is the first occurrence involving the material in Kapar Power Station Malaysia. The investigation includes visual inspections, hardness measurements, and microscopic examinations. The failed super-heater tube shows a wide open rupture with thin and blunt edges. Hardness readings on all the as-received tubes are used for estimating the operating metal temperature of the super-heater tubes. Microstructures of the failed tube show numerous creep cavities consisting of individual pores and chain of pores which form micro-and macro-cracks. The findings confirmed that the super-heater tube is failed by short-term overheating. Higher temperatures of the flue gas due to the inconsistent feeding of pulverized fuels into the burner is identified to cause overheating of the failed tube.

  8. Visual Inspection for Breakage of Micro-milling Cutter

    Directory of Open Access Journals (Sweden)

    WANG Lei

    2014-11-01

    Full Text Available In order to realize visual inspection for breakage of micro-milling cutter, a developed image acquisition method of the surface of a micro-milling cutter was constructed and a classification method based on multilayer neural network was proposed in this article. While the milling cutter was rotating at a constant speed, a camera was triggered by a rotary encoder to capture a series of images. And the developed image of milling cutter was created by image mosaic algorithms. The moment of regional feature as well as the gray feature of the tooth edge was extracted as the input vector of neural network. The feature vector includes moment of inertia, geometric central moment, three-dimensional invariants moment and the gray value of the projection on two principal axis directions of the tooth region. By designing a proper neural network, breakage defects can be detected 100 %. And the false discovery rate is 0.5 %.

  9. Experimental study of the characteristics of the flow in the first rows of tube banks

    International Nuclear Information System (INIS)

    Olinto, Claudio R.; Indrusiak, Maria Luiza S.; Endres, Luiz Augusto M.; Moeller, Sergio V.

    2009-01-01

    This paper presents the experimental study of the flow instabilities in the first rows of tube banks. The study is performed using hot wire anemometry technique in an aerodynamic channel as well as flow visualizations in a water channel. In the wind channel three tube banks with square arrangement and pitch to diameter ratios P/D = 1.26, 1.4 and 1.6 were studied. The Reynolds number range for the velocities measurements, computed with the tube diameter and the flow velocity in the narrow gap between tubes was 7 x 10 4 -8 x 10 4 . Continuous and discrete wavelets were applied to decompose the velocity results, thus allowing the analysis of phenomena in time-frequency domain. Visualizations in a water channel complemented the analysis of the hot wire results. For this purpose, dye was injected in the flow in the water channel with a tube bank with P/D = 1.26. The range of the Reynolds number of the experiments was 3 x 10 4 -4 x 10 4 . The main results show the presence of instabilities, generated after the second row of the tube bank, which propagates to the interior of the bank. In the resulting flow, the three orthogonal components are equally significant. The three-dimensional behavior of the flow is responsible for a mass redistribution inside the bank that leads to velocity values not expected for the studied geometry, according to the known literature. The resulting flow process can be interpreted as a secondary flow which is characteristic of tube banks.

  10. Applying microCT and 3D visualization to Jurassic silicified conifer seed cones: A virtual advantage over thin-sectioning1

    Science.gov (United States)

    Gee, Carole T.

    2013-01-01

    • Premise of the study: As an alternative to conventional thin-sectioning, which destroys fossil material, high-resolution X-ray computed tomography (also called microtomography or microCT) integrated with scientific visualization, three-dimensional (3D) image segmentation, size analysis, and computer animation is explored as a nondestructive method of imaging the internal anatomy of 150-million-year-old conifer seed cones from the Late Jurassic Morrison Formation, USA, and of recent and other fossil cones. • Methods: MicroCT was carried out on cones using a General Electric phoenix v|tome|x s 240D, and resulting projections were processed with visualization software to produce image stacks of serial single sections for two-dimensional (2D) visualization, 3D segmented reconstructions with targeted structures in color, and computer animations. • Results: If preserved in differing densities, microCT produced images of internal fossil tissues that showed important characters such as seed phyllotaxy or number of seeds per cone scale. Color segmentation of deeply embedded seeds highlighted the arrangement of seeds in spirals. MicroCT of recent cones was even more effective. • Conclusions: This is the first paper on microCT integrated with 3D segmentation and computer animation applied to silicified seed cones, which resulted in excellent 2D serial sections and segmented 3D reconstructions, revealing features requisite to cone identification and understanding of strobilus construction. PMID:25202495

  11. Automatic welding of stainless steel tubing

    Science.gov (United States)

    Clautice, W. E.

    1978-01-01

    The use of automatic welding for making girth welds in stainless steel tubing was investigated as well as the reduction in fabrication costs resulting from the elimination of radiographic inspection. Test methodology, materials, and techniques are discussed, and data sheets for individual tests are included. Process variables studied include welding amperes, revolutions per minute, and shielding gas flow. Strip chart recordings, as a definitive method of insuring weld quality, are studied. Test results, determined by both radiographic and visual inspection, are presented and indicate that once optimum welding procedures for specific sizes of tubing are established, and the welding machine operations are certified, then the automatic tube welding process produces good quality welds repeatedly, with a high degree of reliability. Revised specifications for welding tubing using the automatic process and weld visual inspection requirements at the Kennedy Space Center are enumerated.

  12. A novel ZVS high voltage power supply for micro-channel plate photomultiplier tubes

    International Nuclear Information System (INIS)

    Pei, Chengquan; Tian, Jinshou; Liu, Zhen; Qin, Hong; Wu, Shengli

    2017-01-01

    A novel resonant high voltage power supply (HVPS) with zero voltage switching (ZVS), to reduce the voltage stress on switching devices and improve conversion efficiency, is proposed. The proposed HVPS includes a drive circuit, a transformer, several voltage multiplying circuits, and a regulator circuit. The HVPS contains several secondary windings that can be precisely regulated. The proposed HVPS performed better than the traditional resistor voltage divider, which requires replacing matching resistors resulting in resistor dispersibility in the Micro-Channel Plate (MCP). The equivalent circuit of the proposed HVPS was established and the operational principle analyzed. The entire switching element can achieve ZVS, which was validated by a simulation and experiments. The properties of this HVPS were tested including minimum power loss (240 mW), maximum power loss (1 W) and conversion efficiency (85%). The results of this research are that the proposed HVPS was suitable for driving the micro-channel plate photomultiplier tube (MCP-PMT). It was therefore adopted to test the MCP-PMT, which will be used in Daya Bay reactor neutrino experiment II in China.

  13. A novel ZVS high voltage power supply for micro-channel plate photomultiplier tubes

    Energy Technology Data Exchange (ETDEWEB)

    Pei, Chengquan [Key Laboratory for Physical Electronics and Devices of the Ministry of Education, Xi' an Jiaotong University, Xi’an 710049 (China); Tian, Jinshou [Xi’an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi' an 710119 (China); Liu, Zhen [Key Laboratory for Physical Electronics and Devices of the Ministry of Education, Xi' an Jiaotong University, Xi’an 710049 (China); Qin, Hong [School of Computer Science and Technology, Xi' an University of Science and Technology, Xi' an 710054 (China); Wu, Shengli, E-mail: slwu@mail.xjtu.edu.cn [Key Laboratory for Physical Electronics and Devices of the Ministry of Education, Xi' an Jiaotong University, Xi’an 710049 (China)

    2017-04-11

    A novel resonant high voltage power supply (HVPS) with zero voltage switching (ZVS), to reduce the voltage stress on switching devices and improve conversion efficiency, is proposed. The proposed HVPS includes a drive circuit, a transformer, several voltage multiplying circuits, and a regulator circuit. The HVPS contains several secondary windings that can be precisely regulated. The proposed HVPS performed better than the traditional resistor voltage divider, which requires replacing matching resistors resulting in resistor dispersibility in the Micro-Channel Plate (MCP). The equivalent circuit of the proposed HVPS was established and the operational principle analyzed. The entire switching element can achieve ZVS, which was validated by a simulation and experiments. The properties of this HVPS were tested including minimum power loss (240 mW), maximum power loss (1 W) and conversion efficiency (85%). The results of this research are that the proposed HVPS was suitable for driving the micro-channel plate photomultiplier tube (MCP-PMT). It was therefore adopted to test the MCP-PMT, which will be used in Daya Bay reactor neutrino experiment II in China.

  14. Development of the visual inspection system for the top of the tube sheet in steam generators

    International Nuclear Information System (INIS)

    Kim, Gyung Sub; Choi, Sang Hoon; Kim, Ki Chul

    2008-01-01

    Steam Generators at Nuclear Power plants have a important function to isolate Radioactivity between the primary side radioactive fluid running through tubes and the secondary side with non-radioactive fluid through out of a tube bundle, in addition to a function of steam generation. Therefore, To obtain integrity of Steam Generator is really important for safety in the nuclear power plant. At the same time, sludge and foreign objects in steam generators are known as major sources causing the damage of SG tubes. But there is no way to prevent those coming to steam generators until now. Therefore, a periodic inspection and removal of those in steam generators is the only way for those Generally, Most of the Nuclear Power Plants have been inspecting visually every outage for the top of the tube sheet in which sludge and foreign objects lead to the buildup to know how these are

  15. Thermal performance of capillary micro tubes integrated into the sandwich element made of concrete

    DEFF Research Database (Denmark)

    Mikeska, Tomas; Svendsen, Svend

    2013-01-01

    integrated into the thin plate of sandwich element made of HPC can supply the energy needed for heating and cooling. The investigations were conceived as a low temperature concept, where the difference between the temperature of circulating fluid and air in the room was kept in range of 1 to 4°C. © (2013......The thermal performance of radiant heating and cooling systems (RHCS) composed of capillary micro tubes (CMT) integrated into the inner plate of sandwich elements made of High Performance Concrete (HPC) was investigated in the article. Temperature distribution in HPC elements around integrated CMT...

  16. Flow visualization system for wind turbines without blades applied to micro reactors

    International Nuclear Information System (INIS)

    Santos, G.S.B.; Guimarães, L.N.F.; Placco, G.M.

    2017-01-01

    Flow visualization systems is a tool used in science and industry for characterization of projects that operate with drainage. This work presents the design and construction of a flow visualization system for passive turbines used in advanced fast micro reactors. In the system were generated images where it is possible to see the supersonic and transonic flow through the turbine disks. A test bench was assembled to generate images of the interior of the turbine where the flow is supersonic, allowing the study of the behavior of the boundary layer between disks. It is necessary to characterize the boundary layer of this type of turbine because its operation occurs in the transfer of kinetic energy between the fluid and the disks. The images generated, as well as their analyzes are presented as a result of this work

  17. Simulation of TunneLadder traveling-wave tube cold-test characteristics: Implementation of the three-dimensional, electromagnetic circuit analysis code micro-SOS

    Science.gov (United States)

    Kory, Carol L.; Wilson, Jeffrey D.

    1993-01-01

    The three-dimensional, electromagnetic circuit analysis code, Micro-SOS, can be used to reduce expensive time-consuming experimental 'cold-testing' of traveling-wave tube (TWT) circuits. The frequency-phase dispersion characteristics and beam interaction impedance of a TunneLadder traveling-wave tube slow-wave structure were simulated using the code. When reasonable dimensional adjustments are made, computer results agree closely with experimental data. Modifications to the circuit geometry that would make the TunneLadder TWT easier to fabricate for higher frequency operation are explored.

  18. Micro-computed tomography visualization of the vestigial alimentary canal in adult oestrid flies.

    Science.gov (United States)

    Martín-Vega, D; Garbout, A; Ahmed, F; Ferrer, L M; Lucientes, J; Colwell, D D; Hall, M J R

    2018-02-16

    Oestrid flies (Diptera: Oestridae) do not feed during the adult stage as they acquire all necessary nutrients during the parasitic larval stage. The adult mouthparts and digestive tract are therefore frequently vestigial; however, morphological data on the alimentary canal in adult oestrid flies are scarce and a proper visualization of this organ system within the adult body is lacking. The present work visualizes the morphology of the alimentary canal in adults of two oestrid species, Oestrus ovis L. and Hypoderma lineatum (de Villiers), with the use of non-invasive micro-computed tomography (micro-CT) and compares it with the highly developed alimentary canal of the blow fly Calliphora vicina Robineau-Desvoidy (Diptera: Calliphoridae). Both O. ovis and H. lineatum adults showed significant reductions of the cardia and the diameter of the digestive tract, an absence of the helicoidal portion of the midgut typical of other cyclorrhaphous flies, and a lack of crop and salivary glands. Given the current interest in the alimentary canal in adult dipterans in biomedical and developmental biology studies, further understanding of the morphology and development of this organ system in adult oestrids may provide valuable new insights in several areas of research. © 2018 The Royal Entomological Society.

  19. Transport of magneto-nanoparticles during electro-osmotic flow in a micro-tube in the presence of magnetic field for drug delivery application

    Science.gov (United States)

    Mondal, A.; Shit, G. C.

    2017-11-01

    In this paper, we have examined the motion of magnetic-nanoparticles and the flow characteristics of biofluid in a micro-tube in the presence of externally applied magnetic field and electrokinetic effects. In the drug delivery system, the motion of the magnetic nanoparticles as carriers is important for therapeutic procedure in the treatment of tumor cells, infections and removing blood clots. The unidirectional electro-osmotic flow of biofluid is driven by the combined effects of pulsatile pressure gradient and electrokinetic force. The governing equation for unsteady electromagnetohydrodynamic flow subject to the no-slip boundary condition has been solved numerically by using Crank-Nicolson implicit finite difference scheme. We have analyzed the variation of axial velocity, velocity distribution of magnetic nanoparticles, volumetric flow rate and wall shear stress for various values of the non-dimensional parameters. The study reveals that blood flow velocity, carriers velocity and flow rate are strongly influenced by the electro-osmotic parameter as well as the Hartmann number. The particle mass parameter as well as the particle concentration parameter have efficient capturing effect on magnetic nanoparticles during blood flow through a micro-tube for drug delivery.

  20. A cryogenic tensile testing apparatus for micro-samples cooled by miniature pulse tube cryocooler

    International Nuclear Information System (INIS)

    Chen, L B; Liu, S X; Gu, K X; Zhou, Y; Wang, J J

    2015-01-01

    This paper introduces a cryogenic tensile testing apparatus for micro-samples cooled by a miniature pulse tube cryocooler. At present, tensile tests are widely applied to measure the mechanical properties of materials; most of the cryogenic tensile testing apparatus are designed for samples with standard sizes, while for non-standard size samples, especially for microsamples, the tensile testing cannot be conducted. The general approach to cool down the specimens for tensile testing is by using of liquid nitrogen or liquid helium, which is not convenient: it is difficult to keep the temperature of the specimens at an arbitrary set point precisely, besides, in some occasions, liquid nitrogen, especially liquid helium, is not easily available. To overcome these limitations, a cryogenic tensile testing apparatus cooled by a high frequency pulse tube cryocooler has been designed, built and tested. The operating temperatures of the developed tensile testing apparatus cover from 20 K to room temperature with a controlling precision of ±10 mK. The apparatus configurations, the methods of operation and some cooling performance will be described in this paper. (paper)

  1. Tomographic visualization of stress corrosion cracks in tubing

    International Nuclear Information System (INIS)

    Morris, R.A.; Kruger, R.P.; Wecksung, G.W.

    1979-06-01

    A feasibility study was conducted to determine the possibility of detecting and sizing cracks in reactor cooling water tubes using tomographic techniques. Due to time and financial constraints, only one tomographic reconstruction using the best technique available was made. The results indicate that tomographic reconstructions can, in fact, detect cracks in the tubing and might possibly be capable of measuring the depth of the cracks. Limits of detectability and sensitivity have not been determined but should be investigated in any future work

  2. Applied research for profilometric testing of the state of interior surfaces in heat exchanger tubes

    International Nuclear Information System (INIS)

    Gyongyosi, Tiberiu; Panaitescu, Valeriu Nicolae

    2009-01-01

    Generally, the surface flaws identified at heat exchangers tubing are characteristic for the heat secondary systems, located on the external surfaces of the heat exchanger tubes and are mostly the results of the ageing phenomena in systems operation. The tests performed, with the impressing replicating device confirmed the applicability of the technique, functionality of the device and resulted in replicas on metal support, these being the hard copy of the negative of the test tube surface, allowing the profile measurement. The visual inspection of the replicas on the metallic support gives information about the surface geometry replicated, pointing out the marks, which belong to the same area under observation. The minimum and maximum values for the depth of the channel worked out in the inner test tube wall have been determined by profile graphic measurement on the replicas. The paper presents the structural and functional description of the experimental devices. The first results and some conclusions are also included. Two patent applications were submitted at State Office for Inventions and Trademarks (OSIM) covering the original data to protect royalty: 'The local pit flaws, scratches, incipient micro-cracks replicating device on inner cylindrical surfaces', under no. A/00299/17.04.2008 and 'The annular local flaw, incipient micro-cracks replicating device on inner cylindrical surface' under no. A/00300/17.04.2008

  3. Applying microCT and 3D visualization to Jurassic silicified conifer seed cones: A virtual advantage over thin-sectioning.

    Science.gov (United States)

    Gee, Carole T

    2013-11-01

    As an alternative to conventional thin-sectioning, which destroys fossil material, high-resolution X-ray computed tomography (also called microtomography or microCT) integrated with scientific visualization, three-dimensional (3D) image segmentation, size analysis, and computer animation is explored as a nondestructive method of imaging the internal anatomy of 150-million-year-old conifer seed cones from the Late Jurassic Morrison Formation, USA, and of recent and other fossil cones. • MicroCT was carried out on cones using a General Electric phoenix v|tome|x s 240D, and resulting projections were processed with visualization software to produce image stacks of serial single sections for two-dimensional (2D) visualization, 3D segmented reconstructions with targeted structures in color, and computer animations. • If preserved in differing densities, microCT produced images of internal fossil tissues that showed important characters such as seed phyllotaxy or number of seeds per cone scale. Color segmentation of deeply embedded seeds highlighted the arrangement of seeds in spirals. MicroCT of recent cones was even more effective. • This is the first paper on microCT integrated with 3D segmentation and computer animation applied to silicified seed cones, which resulted in excellent 2D serial sections and segmented 3D reconstructions, revealing features requisite to cone identification and understanding of strobilus construction.

  4. Bacterial Biofilms in Jones Tubes.

    Science.gov (United States)

    Ahn, Eric S; Hauck, Matthew J; Kirk Harris, Jonathan; Robertson, Charles E; Dailey, Roger A

    To investigate the presence and microbiology of bacterial biofilms on Jones tubes (JTs) by direct visualization with scanning electron microscopy and polymerase chain reaction (PCR) of representative JTs, and to correlate these findings with inflammation and/or infection related to the JT. In this study, prospective case series were performed. JTs were recovered from consecutive patients presenting to clinic for routine cleaning or recurrent irritation/infection. Four tubes were processed for scanning electron microscopy alone to visualize evidence of biofilms. Two tubes underwent PCR alone for bacterial quantification. One tube was divided in half and sent for scanning electron microscopy and PCR. Symptoms related to the JTs were recorded at the time of recovery. Seven tubes were obtained. Five underwent SEM, and 3 out of 5 showed evidence of biofilms (60%). Two of the 3 biofilms demonstrated cocci and the third revealed rods. Three tubes underwent PCR. The predominant bacteria identified were Pseudomonadales (39%), Pseudomonas (16%), and Staphylococcus (14%). Three of the 7 patients (43%) reported irritation and discharge at presentation. Two symptomatic patients, whose tubes were imaged only, revealed biofilms. The third symptomatic patient's tube underwent PCR only, showing predominantly Staphylococcus (56%) and Haemophilus (36%) species. Two of the 4 asymptomatic patients also showed biofilms. All symptomatic patients improved rapidly after tube exchange and steroid antibiotic drops. Bacterial biofilms were variably present on JTs, and did not always correlate with patients' symptoms. Nevertheless, routine JT cleaning is recommended to treat and possibly prevent inflammation caused by biofilms.

  5. Laser/fluorescent dye flow visualization technique developed for system component thermal hydraulic studies

    International Nuclear Information System (INIS)

    Oras, J.J.; Kasza, K.E.

    1988-01-01

    A novel laser flow visualization technique is presented together with examples of its use in visualizing complex flow patterns and plans for its further development. This technique has been successfully used to study (1) the flow in a horizontal pipe subject to temperature transients, to view the formation and breakup of thermally stratified flow and to determine instantaneous velocity distributions in the same flow at various axial locations; (2) the discharge of a stratified pipe flow into a plenum exhibiting a periodic vortex pattern; and (3) the thermal-buoyancy-induced flow channeling on the shell side of a heat exchanger with glass tubes and shell. This application of the technique to heat exchangers is unique. The flow patterns deep within a large tube bundle can be studied under steady or transient conditions. This laser flow visualization technique constitutes a very powerful tool for studying single or multiphase flows in complex thermal system components

  6. Post-Dryout Heat Transfer to a Refrigerant Flowing in Horizontal Evaporator Tubes

    Science.gov (United States)

    Mori, Hideo; Yoshida, Suguru; Kakimoto, Yasushi; Ohishi, Katsumi; Fukuda, Kenichi

    Studies of the post-dryout heat transfer were made based on the experimental data for HFC-134a flowing in horizontal smooth and spiral1y grooved (micro-fin) tubes and the characteristics of the post-dryout heat transfer were c1arified. The heat transfer coefficient at medium and high mass flow rates in the smooth tube was lower than the single-phase heat transfer coefficient of the superheated vapor flow, of which mass flow rate was given on the assumption that the flow was in a thermodynamic equilibrium. A prediction method of post-dryout heat transfer coefficient was developed to reproduce the measurement satisfactorily for the smooth tube. The post dryout heat transfer in the micro-fin tube can be regarded approximately as a superheated vapor single-phase heat transfer.

  7. Outcomes of glaucoma reoperations in the Tube Versus Trabeculectomy (TVT) Study.

    Science.gov (United States)

    Saheb, Hady; Gedde, Steven J; Schiffman, Joyce C; Feuer, William J

    2014-06-01

    To describe the incidence and outcomes of reoperations for glaucoma in the Tube Versus Trabeculectomy (TVT) Study. Cohort study of patients in a multicenter randomized clinical trial. The TVT Study enrolled 212 patients with medically uncontrolled glaucoma who had previous cataract and/or glaucoma surgery. Randomization assigned 107 patients to surgery with a tube shunt (350 mm(2) Baerveldt glaucoma implant) and 105 patients to trabeculectomy with mitomycin C (0.4 mg/mL for 4 minutes). Data were analyzed from patients who failed their assigned treatment and had additional glaucoma surgery. Outcome measures included intraocular pressure (IOP), use of glaucoma medications, visual acuity, surgical complications, and failure (IOP >21 mm Hg or not reduced by 20%, IOP ≤5 mm Hg, additional glaucoma surgery, or loss of light perception vision). Additional glaucoma surgery was performed in 8 patients in the tube group and 18 patients in the trabeculectomy group in the TVT Study, and the 5-year cumulative reoperation rate was 9% in the tube group and 29% in the trabeculectomy group (P = .025). Follow-up (mean ± SD) after additional glaucoma surgery was 28.0 ± 16.0 months in the tube group and 30.5 ± 20.4 months in the trabeculectomy group (P = .76). At 2 years after a glaucoma reoperation, IOP (mean ± SD) was 15.0 ± 5.5 mm Hg in the tube group and 14.4 ± 6.6 mm Hg in the trabeculectomy group (P = .84). The number of glaucoma medications (mean ± SD) after 2 years of follow-up was 1.1 ± 1.3 in the tube group and 1.4 ± 1.4 in the trabeculectomy group (P = .71). The cumulative probability of failure at 1, 2, 3, and 4 years after additional glaucoma surgery was 0%, 43%, 43%, and 43%, respectively, in the tube group, and 0%, 9%, 20%, and 47% in the trabeculectomy group (P = .28). Reoperations to manage complications were required in 1 patient in the tube group and 5 patients in the trabeculectomy group (P = .63). The rate of reoperation for glaucoma was higher following

  8. A study of self-propelled elastic cylindrical micro-swimmers using modeling and computation

    Science.gov (United States)

    Shi, Lingling; Čanić, Sunčica; Quaini, Annalisa; Pan, Tsorng-Whay

    2016-06-01

    We study propulsion of micro-swimmers in 3D creeping flow. The swimmers are assumed to be made of elastic cylindrical hollow tubes. The swimming is generated by the contractions of the tube's elastic membrane walls producing a traveling wave in the form of a ;step-function; traversing the swimmer from right to left, propelling the swimmer from left to right. The problem is motivated by medical applications such as drug delivery. The influence of several non-dimensional design parameters on the velocity of the swimmer is investigated, including the swimmer aspect ratio, and the amplitude of the traveling wave relative to the swimmer radius. An immersed boundary method based on a finite element method approach is successfully combined with an elastic spring network model to simulate the two-way fluid-structure interaction coupling between the elastic cylindrical tube and the flow of a 3D viscous, incompressible fluid. To gain a deeper insight into the influence of various parameters on the swimmer speed, a reduced 1D fluid-structure interaction model was derived and validated. It was found that fast swimmers are those with large tube aspect ratios, and with the amplitude of the traveling wave which is roughly 50% of the reference swimmer radius. It was shown that the speed of our ;optimal swimmer; is around 1.5 swimmer lengths per second, which is at the top of the class of all currently manufactured micro-swimmers swimming in low Reynolds number flows (Re =10-6), reported in [11].

  9. Electrospun micro- and nanofiber tubes for functional nervous regeneration in sciatic nerve transections

    Directory of Open Access Journals (Sweden)

    Amadio Stefano

    2008-04-01

    Full Text Available Abstract Background Although many nerve prostheses have been proposed in recent years, in the case of consistent loss of nervous tissue peripheral nerve injury is still a traumatic pathology that may impair patient's movements by interrupting his motor-sensory pathways. In the last few decades tissue engineering has opened the door to new approaches;: however most of them make use of rigid channel guides that may cause cell loss due to the lack of physiological local stresses exerted over the nervous tissue during patient's movement. Electrospinning technique makes it possible to spin microfiber and nanofiber flexible tubular scaffolds composed of a number of natural and synthetic components, showing high porosity and remarkable surface/volume ratio. Results In this study we used electrospun tubes made of biodegradable polymers (a blend of PLGA/PCL to regenerate a 10-mm nerve gap in a rat sciatic nerve in vivo. Experimental groups comprise lesioned animals (control group and lesioned animals subjected to guide conduits implantated at the severed nerve stumps, where the tubular scaffolds are filled with saline solution. Four months after surgery, sciatic nerves failed to reconnect the two stumps of transected nerves in the control animal group. In most of the treated animals the electrospun tubes induced nervous regeneration and functional reconnection of the two severed sciatic nerve tracts. Myelination and collagen IV deposition have been detected in concurrence with regenerated fibers. No significant inflammatory response has been found. Neural tracers revealed the re-establishment of functional neuronal connections and evoked potential results showed the reinnervation of the target muscles in the majority of the treated animals. Conclusion Corroborating previous works, this study indicates that electrospun tubes, with no additional biological coating or drug loading treatment, are promising scaffolds for functional nervous regeneration. They

  10. Catalyst Particles for Fluid Catalytic Cracking Visualized at the Individual Particle Level by Micro-Spectroscopy

    NARCIS (Netherlands)

    Buurmans, I.L.C.

    2011-01-01

    In this PhD research the investigation of the reactivity and acidity of Fluid Catalytic Cracking (FCC) catalysts at the level of an individual catalyst particles is described. A range of micro-spectroscopic techniques has been applied to visualize both the active zeolite component within the

  11. Experimental study of flow patterns near tube support structures

    International Nuclear Information System (INIS)

    Rummens, H.E.C.; Turner, C.W.

    1994-07-01

    Extensive blockage of broached support plates in steam generators has occurred at the Bruce A Nuclear Generating Station (NGS), forcing unit derating in 1988 March. Blockage has also been found on the lower broached plates of the Pickering B and Point Lepreau NGSs. Water chemistry and operating conditions are known to influence fouling directly. We suspect that flow patterns also play a role, that these patterns are influenced by the geometry of steam generator (SG) components, and that particularly the broached plate design actively creates an environment favorable to deposition. Experiments are in progress to examine the flow patterns near various tube supports: the broached plate, two types of lattice bars, and the formed bars. Preliminary tests in an air/water loop with 1/2- and 7-tube SG mockups containing the tube supports have been completed. Flow patterns were visualized using injected air bubbles. Local velocities and turbulence levels were measured using a laser technique, which confirmed observations of flow recirculation and stagnation. Axial pressure profiles were measured to determine overall resistance coefficients, and to identify local pressure extremes. Some visualization tests were also carried out on an artificially fouled broached plate. Based on results to date, several deposition mechanisms are proposed: deposition of particles in stagnant regions, deposition of solubles due to flashing in low-pressure regions, and deposition in smaller channels due to steam migration toward larger channels. A qualitative assessment of the tube support designs based on these mechanisms implies that the relative resistances to fouling are: (WORST) broach plate << lattice bars << formed bars (BEST). As the air/water simulation shows only hydraulic flow patterns, further tests will be done in a simple liquid/vapor Freon loop to examine thermal effects. (author). 3 refs., 10 figs

  12. Robust precision alignment algorithm for micro tube laser forming

    NARCIS (Netherlands)

    Folkersma, Ger; Brouwer, Dannis Michel; Römer, Gerardus Richardus, Bernardus, Engelina; Herder, Justus Laurens

    2016-01-01

    Tube laser forming on a small diameter tube can be used as a high precision actuator to permanently align small (optical)components. Applications, such as the alignment of optical fibers to photonic integrated circuits, often require sub-micron alignment accuracy. Although the process causes

  13. Investigation on the heat transfer characteristics during flow boiling of liquefied natural gas in a vertical micro-fin tube

    Science.gov (United States)

    Xu, Bin; Shi, Yumei; Chen, Dongsheng

    2014-03-01

    This paper presents an experimental investigation on the heat transfer characteristics of liquefied natural gas flow boiling in a vertical micro-fin tube. The effect of heat flux, mass flux and inlet pressure on the flow boiling heat transfer coefficients was analyzed. The Kim, Koyama, and two kinds of Wellsandt correlations with different Ftp coefficients were used to predict the flow boiling heat transfer coefficients. The predicted results showed that the Koyama correlation was the most accurate over the range of experimental conditions.

  14. Experimental study on two-phase flow in horizontal duct using a visualization technique

    International Nuclear Information System (INIS)

    Oliveira, Livia A.; Tomas, Bruno T.; Cunha Filho, Jurandyr S.; Su, Jian

    2009-01-01

    In this paper an experimental study is performed for visualization of water-air two phase flow, stratified and intermittent, in a 51 mm internal diameter circular section horizontal tube. The study consists in filming a water-air mixture passin by a transparent interval of the tube, using a high speed camera. After that, the obtained images are analysed frame after frame and then, data are extracted of weight of gas-liquid interfaces, length and gas bubbles speeds. Then, these data are verified with experimental and theoretical correlations available in the literature

  15. Visualization of frosting phenomena by using neutron radiography

    International Nuclear Information System (INIS)

    Yoshimura, Tomoya; Matsumoto, Ryosuke; Umekawa, Hisashi; Ami, Takeyuki; Saito, Yasushi

    2012-01-01

    This study focuses on the frost formation on the fin-tube heat exchanger using neutron radiography. The visualization of the frost formation was estimated by the attenuation of the neutron beam through the water. The visualization image of the neutron radiography shows clearly the frost formation phenomena on the fin-tube heat exchanger. The rapid frost formation was observed at the fin and tube edges. Local mass transfer coefficient can be calculated from the differential images of the neutron radiography. (author)

  16. A Built for Purpose Micro-Hole Coiled Tubing Rig (MCTR)

    Energy Technology Data Exchange (ETDEWEB)

    Bart Patton

    2007-09-30

    This report will serve as the final report on the work performed from the contract period October 2005 thru April 2007. The project 'A Built for Purpose Microhole Coiled Tubing Rig (MCTR)' purpose was to upgrade an existing state-of-the-art Coiled Tubing Drilling Rig to a Microhole Coiled Tubing Rig (MCTR) capable of meeting the specifications and tasks of the Department of Energy. The individual tasks outlined to meet the Department of Energy's specifications are: (1) Concept and development of lubricator and tool deployment system; (2) Concept and development of process control and data acquisition; (3) Concept and development of safety and efficiency improvements; and (4) Final unit integration and testing. The end result of the MCTR upgrade has produced a unit capable of meeting the following requirements: (1) Capable of handling 1-inch through 2-3/8-inch coiled tubing (Currently dressed for 2-3/8-inch coiled tubing and capable of running up to 3-1/2-inch coiled tubing); (2) Capable of drilling and casing surface, intermediate, production and liner hole intervals; (3) Capable of drilling with coiled tubing and has all controls and installation piping for a top drive; (4) Rig is capable of running 7-5/8-inch range 2 casing; and (5) Capable of drilling 5,000 ft true vertical depth (TVD) and 6,000 ft true measured depth (TMD).

  17. Paramecium swimming in a capillary tube

    Science.gov (United States)

    Jana, Saikat; Jung, Sunghwan

    2010-03-01

    Micro-organisms exhibit different strategies for swimming in complex environments. Many micro-swimmers such as paramecium congregate and tend to live near wall. We investigate how paramecium moves in a confined space as compared to its motion in an unbounded fluid. A new theoretical model based on Taylor's sheet is developed, to study such boundary effects. In experiments, paramecia are put inside capillary tubes and their swimming behavior is observed. The data obtained from experiments is used to test the validity of our theoretical model and understand how the cilia influence the locomotion of paramecia in confined geometries.

  18. Visualization of haemophilic arthropathy in F8(-/-) rats by ultrasonography and micro-computed tomography

    DEFF Research Database (Denmark)

    Christensen, K R; Roepstorff, K; Petersen, M

    2017-01-01

    opportunities. Recently, a F8(-/-) rat model of HA was developed. The size of the rat allows for convenient and high resolution imaging of the joints, which could enable in vivo studies of HA development. AIM: To determine whether HA in the F8(-/-) rat can be visualized using ultrasonography (US) and micro......-computed tomography (μCT). METHODS: Sixty F8(-/-) and 20 wild-type rats were subjected to a single or two induced knee bleeds. F8(-/-) rats were treated with either recombinant human FVIII (rhFVIII) or vehicle before the induction of knee bleeds. Haemophilic arthropathy was visualized using in vivo US and ex vivo μCT......, and the observations correlated with histological evaluation. RESULTS: US and μCT detected pathologies in the knee related to HA. There was a strong correlation between disease severity determined by μCT and histopathology. rhFVIII treatment reduced the pathology identified with both imaging techniques. CONCLUSION: US...

  19. Study on antioxidant experiment on forged steel tube sheet and tube hole for steam generator

    International Nuclear Information System (INIS)

    Zong Hai; Wang Detai; Ding Yang

    2012-01-01

    Antioxidant experiment on forged steel tube sheet and tube hole for steam generator was studied and the influence of different simulated heat treatments on the antioxidant performance of tube sheet and tube hole was made. The influence of different antioxidant methods on the size of tube hole was drawn. Furthermore, the change of size and weight of 18MnD5 forged steel tube sheet on the condition of different simulated heat treatments was also studied. The analytical results have proved reference information for the use of 18MnD5 material and for key processes of processing tube hole and wearing and expanding U-style tube. (authors)

  20. Combustion and direct energy conversion inside a micro-combustor

    International Nuclear Information System (INIS)

    Lei, Yafeng; Chen, Wei; Lei, Jiang

    2016-01-01

    Highlights: • The flammability range of micro-combustor was broadened with heat recirculation. • The quenching diameter decreased with heat recirculation compared to without recirculation. • The surface areas to volume ratio was the most important parameter affecting the energy conversion efficiency. • The maximum conversion efficiency (3.15%) was achieved with 1 mm inner diameter. - Abstract: Electrical energy can be generated by employing a micro-thermophotovoltaic (TPV) cell which absorbs thermal radiation from combustion taking place in a micro-combustor. The stability of combustion in a micro-combustor is essential for operating a micro-power system using hydrogen and hydrocarbon fuels as energy source. To understand the mechanism of sustaining combustion within the quenching distance of fuel, this study proposed an annular micro combustion tube with recirculation of exhaust heat. To explore the feasibility of combustion in the micro annular tube, the parameters influencing the combustion namely, quenching diameter, and flammability were studied through numerical simulation. The results indicated that combustion could be realized in micro- combustor using heat recirculation. Following results were obtained from simulation. The quenching diameter reduced from 1.3 mm to 0.9 mm for heat recirculation at equivalence ratio of 1; the lean flammability was 2.5%–5% lower than that of without heat recirculation for quenching diameters between 2 mm and 5 mm. The overall energy conversion efficiency varied at different inner diameters. A maximum efficiency of 3.15% was achieved at an inner diameter of 1 mm. The studies indicated that heat recirculation is an effective strategy to maintain combustion and to improve combustion limits in micro-scale system.

  1. A study of effective sequences on micro-CT in the dent-maxillo-facial region

    International Nuclear Information System (INIS)

    Kato, Masataka; Mori, Shintaro; Sakayanagi, Masashi; Fujita, Yuzo; Kaneda, Takashi

    2005-01-01

    Microfocus computed tomography (micro-CT) using cone-beam scan is becoming widely used for various studies of oral structures. However, this machine has not been used to evaluate the effective parameters for two-dimensional (2D) or three-dimensional (3D) images. This study evaluated the effective parameters of micro-CT for 2D or 3D images of oral hard tissue structures. We evaluated the CT value of 5 human teeth (upper first molars) to determine suitable CT value examined according to several X-ray parameters using conformal radiotherapy (CRT) on a work station. CT information from the specimens was obtained using a micro-CT (Toscaner-31300 μ, Toshiba ITC), under the conditions of tube voltage of 75 kV, tube current of 120 μA, 100∼1600 views, the number of times of addition, 512 x 512 pixel matrix, and 0.2 slice thickness. We made 3D-reconstruction images from the micro-CT data. Three-dimensional reconstruction was performed using 2D images processed by the volume-rendering method using 3D-reconstruction software (TRI/3D BON, RATOC system engineering). Then, we evaluate the 3D tooth images. In the assessment of images, three dental radiologists evaluated several 3D tooth images using 3D-reconstruction images. Each image was scored on a five-level scale by Scheffe one-pair comparison method as follows: 5: much easier to evaluate, 4: easier to evaluate, 3: equivalent, 2: harder to evaluate, 1: much harder to evaluate. In scoring, each of the three dental radiologists made an individual assessment, and when differences among individual scores occurred, the score was ultimately assigned by consensus among the three individuals. Statistical analysis of the scores assigned by the three dental radiologists as described above was carried out using Stat View-J 5.0 (Abacus Concepts, Inc, USA) statistical software and Tukey-Kramer multiple-comparison testing. The optimal CT value for evaluating the human tooth by micro-CT is 600 on 2D images. On 3D images, the optimal

  2. The application of μPIV technique in the study of magnetic flows in a micro-channel

    International Nuclear Information System (INIS)

    Nguyen, N.T.; Wu, Z.G.; Huang, X.Y.; Wen, C.-Y..

    2005-01-01

    In this preliminary experimental study, micro-scale particle image velocimetry (μPIV) was adopted for the first time to get the quantitative information of magnetic flows in a micro-channel. The μPIV consists of an inverted florescent microscope, a Q-switch Nd:YAG laser and a CCD camera. The florescent liquid with particles of 3 μm diameter was blended homogeneously with the prepared magnetic fluid. A permanent magnet approached and left one end of the micro-channel. The response of the magnetic fluid was recorded with the μPIV simultaneously. The flow features validate the feasibility of using μPIV technique in the study of magnetic flows in a micro-channel. μPIV provides a promising experimental tool for visualization and quantitative measurement of magnetic micro-flows

  3. Micro manometer and pitot tube for measuring the velocity distribution in a natural convection water stream between two vertical parallel plates (1961); Micromano metre et tube de pitot destines a l'exploration du profil de vitesse dans un ecoulement d'eau de convection naturelle entre deux plaques verticales paralleles (1961)

    Energy Technology Data Exchange (ETDEWEB)

    Santon, L; Vernier, Ph [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1961-07-01

    For heat transfer studies in certain cases of cooling in swimming-pool type nuclear reactors, a knowledge of the distribution of the velocities between two heating elements is of prime importance. A Pitot tube and a micro-manometer have been developed for making these measurements on an experimental model. (authors) [French] Pour l'etude du transfert de chaleur dans certains cas de refroidissement des reacteurs nucleaires du type piscine, la connaissance de la repartition des vitesses entre deux elements chauffants est primordiale. On a mis au point un tube de Pitot et un micromanometre pour effectuer ces mesures sur une maquette experimentale. (auteurs)

  4. Microscopic Pillars and Tubes Fabricated by Using Fish Dentine as a Molding Template

    Directory of Open Access Journals (Sweden)

    Weiqun Li

    2014-08-01

    Full Text Available Biomaterials in nature exhibit delicate structures that are greatly beyond the capability of the current manufacturing techniques. Duplicating these structures and applying them in engineering may help enhance the performance of traditional functional materials and structures. Inspired by gecko’s hierarchical micro- and nano-fibrillar structures for adhesion, in this work we fabricated micro-pillars and tubes by adopting the tubular dentine of black carp fish teeth as molding template. The adhesion performances of the fabricated micro-pillars and tubes were characterized and compared. It was found that the pull-off force of a single pillar was about twice of that of the tube with comparable size. Such unexpected discrepancy in adhesion was analyzed based on the contact mechanics theories.

  5. CFD investigation of flow through internally riffled boiler tubes

    DEFF Research Database (Denmark)

    Rasmussen, Christian; Houbak, Niels; Sørensen, Jens Nørkær

    1997-01-01

    In this paper we show how to model the swirling flow in an internally riffled boiler tube. The flow field is visualized and the results are compared with measurements.......In this paper we show how to model the swirling flow in an internally riffled boiler tube. The flow field is visualized and the results are compared with measurements....

  6. An experimental study on micro-scale flow boiling heat transfer

    International Nuclear Information System (INIS)

    Tibirica, Cristiano Bigonha; Ribatski, Gherhardt

    2009-01-01

    In this paper, new experimental flow boiling heat transfer results in micro-scale tubes are presented. The experimental data were obtained in a horizontal 2.32 mm I.D. stainless steel tube with heating length of 464 mm, R134a as working fluid, mass velocities ranging from 50 to 600 kg/m 2 s, heat flux from 5 to 55 kW/m 2 , exit saturation temperatures of 22, 31 and 41 deg C, and vapor qualities from 0.05 to 0.98. Flow pattern characterization was also performed from images obtained by high speed filming. Heat transfer coefficient results from 2 to 14 kW/m 2 K were measured. It was found that the heat transfer coefficient is a strong function of the saturation pressure, heat flux, mass velocity and vapor quality. The experimental data were compared against the following micro-scale flow boiling predictive methods from the literature: Saitoh et al., Kandlikar, Zhang et al. and Thome et al. Comparisons against these methods based on the data segregated according to flow patterns were also performed. Though not satisfactory, Saitoh et al. worked the best and was able of capturing most of the experimental heat transfer trends. (author)

  7. An experimental study on micro-scale flow boiling heat transfer

    Energy Technology Data Exchange (ETDEWEB)

    Tibirica, Cristiano Bigonha; Ribatski, Gherhardt [Universidade de Sao Paulo (USP), Sao Carlos, SP (Brazil). Escola de Engenharia. Dept. de Engenharia Mecanica

    2009-07-01

    In this paper, new experimental flow boiling heat transfer results in micro-scale tubes are presented. The experimental data were obtained in a horizontal 2.32 mm I.D. stainless steel tube with heating length of 464 mm, R134a as working fluid, mass velocities ranging from 50 to 600 kg/m{sup 2}s, heat flux from 5 to 55 kW/m{sup 2}, exit saturation temperatures of 22, 31 and 41 deg C, and vapor qualities from 0.05 to 0.98. Flow pattern characterization was also performed from images obtained by high speed filming. Heat transfer coefficient results from 2 to 14 kW/m{sup 2}K were measured. It was found that the heat transfer coefficient is a strong function of the saturation pressure, heat flux, mass velocity and vapor quality. The experimental data were compared against the following micro-scale flow boiling predictive methods from the literature: Saitoh et al., Kandlikar, Zhang et al. and Thome et al. Comparisons against these methods based on the data segregated according to flow patterns were also performed. Though not satisfactory, Saitoh et al. worked the best and was able of capturing most of the experimental heat transfer trends. (author)

  8. Flow patterns during refrigerant condensation in smooth and enhanced tubes

    OpenAIRE

    2009-01-01

    M.Ing. The Montreal Protocol led to the phasing-out of ozone layer depleting refrigerants and replacing them with more environmentally friendly refrigerants, which in many cases caused heat transfer degradation in heat exchanger equipment. To make up for the heat transfer degradation, there was a need for the application of heat transfer enhancement techniques. One such technique is the use of micro-fin tubes as opposed to traditional smooth tubes. The purpose of this study is to develop a...

  9. Barbed micro-spikes for micro-scale biopsy

    Science.gov (United States)

    Byun, Sangwon; Lim, Jung-Min; Paik, Seung-Joon; Lee, Ahra; Koo, Kyo-in; Park, Sunkil; Park, Jaehong; Choi, Byoung-Doo; Seo, Jong Mo; Kim, Kyung-ah; Chung, Hum; Song, Si Young; Jeon, Doyoung; Cho, Dongil

    2005-06-01

    Single-crystal silicon planar micro-spikes with protruding barbs are developed for micro-scale biopsy and the feasibility of using the micro-spike as a micro-scale biopsy tool is evaluated for the first time. The fabrication process utilizes a deep silicon etch to define the micro-spike outline, resulting in protruding barbs of various shapes. Shanks of the fabricated micro-spikes are 3 mm long, 100 µm thick and 250 µm wide. Barbs protruding from micro-spike shanks facilitate the biopsy procedure by tearing off and retaining samples from target tissues. Micro-spikes with barbs successfully extracted tissue samples from the small intestines of the anesthetized pig, whereas micro-spikes without barbs failed to obtain a biopsy sample. Parylene coating can be applied to improve the biocompatibility of the micro-spike without deteriorating the biopsy function of the micro-spike. In addition, to show that the biopsy with the micro-spike can be applied to tissue analysis, samples obtained by micro-spikes were examined using immunofluorescent staining. Nuclei and F-actin of cells which are extracted by the micro-spike from a transwell were clearly visualized by immunofluorescent staining.

  10. Study of Weld Imperfections on Thin Aluminum Tubes According To ISO 10042

    CERN Document Server

    Rizkallah, Rabel

    2014-01-01

    The following report presents the work done as part of my summer student internship at CERN in the EN/MME group, and is divided into two parts. Part I of the report is a continuation of the work started previously by the student Quentin Drouhet, which aims at studying and classifying welding imperfections on various materials of small thicknesses. Drouhet worked on the welding imperfections found on thin Stainless Steel plates of thicknesses of 2 and 6 millimeters, welded using the GTAW (or TIG welding) process. My job was to conduct a similar study on thin Aluminum tubes welded using this same process. Part II of the report will introduce a new method for defect analysis that is still not available at CERN: the micro-tomographic testing

  11. High-Temperature Graphitization Failure of Primary Superheater Tube

    Science.gov (United States)

    Ghosh, D.; Ray, S.; Roy, H.; Mandal, N.; Shukla, A. K.

    2015-12-01

    Failure of boiler tubes is the main cause of unit outages of the plant, which further affects the reliability, availability and safety of the unit. So failure analysis of boiler tubes is absolutely essential to predict the root cause of the failure and the steps are taken for future remedial action to prevent the failure in near future. This paper investigates the probable cause/causes of failure of the primary superheater tube in a thermal power plant boiler. Visual inspection, dimensional measurement, chemical analysis, metallographic examination and hardness measurement are conducted as the part of the investigative studies. Apart from these tests, mechanical testing and fractographic analysis are also conducted as supplements. Finally, it is concluded that the superheater tube is failed due to graphitization for prolonged exposure of the tube at higher temperature.

  12. Radioisotope study of Eustachian tube

    International Nuclear Information System (INIS)

    De Rossi, G.; Campioni, P.; Vaccaro, A.

    1988-01-01

    Radioisotope studies of Eustachian tube are suggested in the preoperative phase of tympanoplasty, in order to assess tubal drainage and secretion. The use of gamma camera fitted to a computer allowed the AA, to calculate some semi-quantitative parameters for an exact assessment of the radioactivity transit from the tympanic cass up to the pharyngeal cavity, throughout the Eustachian tube. (orig.) [de

  13. Micro-radiography and micro-computerized tomography with absorption and phase contrast for materials characterization; Mikro-Radiografie und Mikro-Computertomografie mit Absorptions- und Phasenkontrast fuer die Materialcharakterisierung

    Energy Technology Data Exchange (ETDEWEB)

    Kastner, Johann [FH Oberoesterreich, Wels (Austria)

    2017-08-01

    The contribution describes modern techniques in micro-radiography and micro-computerized tomography for materials characterization using absorption and phase contrast. Using micro- and nano-focus tubes and adequate high.-resolution detectors it is possible to reach resolutions significantly below 1 micron. The CT technology allows in-situ deformation testing to study the damaging mechanism of materials. The application of the Talbot-Lau interferometer with CT a differential phase contrast tomography is available. Dark-field tomography is used to study individual carbon fiber bundles in carbon fiber reinforced laminates.

  14. On viscosity measurements of nanofluids in micro and mini tube flow

    International Nuclear Information System (INIS)

    Egan, V M; Walsh, P A; Walsh, E J

    2009-01-01

    This study presents measurements on the relative viscosity of Al 2 O 3 nanofluids, obtained using capillary and rotational viscometers. Suspension volume concentrations between 0.3% and 6.3% were considered and all exhibited Newtonian behaviour. This paper questions previously published data (Jang et al 2007 Appl. Phys. Lett. 91 243112) which show effective viscosity measurements of nanofluids to be strongly dependent on the tube dimension used in a microscale capillary viscometer. Hence, tubes of diameter 337 μm and 1017 μm were employed but no effect on relative viscosity was observed as all measurements compared favourably. Additionally, all viscosity measurements were found to correlate well using classical models when aggregate size was considered in calculating volume concentration.

  15. Experimental study of tube/support impact forces in multi-span PWR steam generator tubes

    International Nuclear Information System (INIS)

    Axisa, F.; Desseaux, A.; Gibert, R.J.

    1984-12-01

    The vibro-impact response of a straight part of a steam generator tube is investigated experimentally and using numerical simulation with the aim to relate tube overall dynamics with excitation and tube-support clearance. Configuration studied here corresponds to the tube being excited in only one direction at its first resonance presenting an antinode of vibration at the impacted support. Tests show namely that midspan displacement of tube is almost proportional to excitation level and clearance. Impact forces averaged over a cycle of vibration are almost proportional to excitation and poorly dependent on clearance. Results of numerical simulation are in fairly good agreement with test results

  16. Stability of Balloon-Retention Gastrostomy Tubes with Different Concentrations of Contrast Material: In Vitro Study

    International Nuclear Information System (INIS)

    Lopera, Jorge E.; Alvarez, Alex; Trimmer, Clayton; Josephs, Shellie; Anderson, Matthew; Dolmatch, Bart

    2009-01-01

    The purpose of this study was to determine the performance of two balloon-retention-type gastrostomy tubes when the balloons are inflated with two types of contrast materials at different concentrations. Two commonly used balloon-retention-type tubes (MIC and Tri-Funnel) were inflated to the manufacturer's recommended volumes (4 and 20 cm 3 , respectively) with normal saline or normal saline plus different concentrations of contrast material. Five tubes of each brand were inflated with normal saline and 0%, 25%, 50%, 75%, and 100% contrast material dilutions, using either nonionic hyperosmolar contrast, or nonionic iso-osmolar contrast. The tubes were submerged in a glass basin containing a solution with a pH of 4. Every week the tubes were visually inspected to determine the integrity of the balloons, and the diameter of the balloons was measured with a caliper. The tests were repeated every week for a total of 12 weeks. The MIC balloons deflated slightly faster over time than the Tri-Funnel balloons. The Tri-Funnel balloons remained relatively stable over the study period for the different concentrations of contrast materials. The deflation rates of the MIC balloons were proportionally related to the concentration of saline and inversely related to the concentration of the contrast material. At high contrast material concentrations, solidification of the balloons was observed. In conclusion, this in vitro study confirms that the use of diluted amounts of nonionic contrast materials is safe for inflating the balloons of two types of balloon-retention feeding tubes. High concentrations of contrast could result in solidification of the balloons and should be avoided.

  17. Superconducting vortex dynamics in cylindrical Nb micro- and nanotubes

    Energy Technology Data Exchange (ETDEWEB)

    Fomin, Vladimir M. [Institute for Integrative Nanosciences, IFW-Dresden, D-01069 Dresden (Germany); Rezaev, Roman O. [Institute for Integrative Nanosciences, IFW-Dresden, D-01069 Dresden (Germany); Laboratory of Mathematical Physics, Tomsk Polytechnic University, 634050 Tomsk (Russian Federation); Schmidt, Oliver G. [Institute for Integrative Nanosciences, IFW-Dresden, D-01069 Dresden (Germany); Material Systems for Nanoelectronics, Chemnitz University of Technology, D-09107 Chemnitz (Germany)

    2012-07-01

    Advancements in fabrication of rolled-up micro- and nanotubes including superconductor layers (e.g., InGaAs/GaAs/Nb) open new ways for investigation of the vortex matter in superconductors with curved geometries. Geometry determines the dynamics of vortices in the presence of transport currents in open superconductor micro- and nanotubes subject to a magnetic field orthogonal to the axis. Vortices nucleate periodically at one edge of the tube, subsequently move along the tube under the action of the Lorentz force and denucleate at the opposite edge of the tube. Characteristic times of nonequilibrium vortex dynamics in an open tube are efficiently controlled by the tube radius. The magnetic field, at which the vortices begin to nucleate at the edge of the structure, is increased several times by rolling up a planar film in a tube. This effect is caused not only by a spatial dependence of the magnetic field component normal to the cylindrical surface, but also by correlations between the states of the superconducting order parameter in the opposite areas of the cylindrical surface.

  18. Development of a running robot in super high speed tube. Aiming at realization of in-tube inspection for primary cooler and so forth of nuclear reactor

    International Nuclear Information System (INIS)

    Kato, Shigeo

    2000-01-01

    Authors have carried out a study on an in-tube running robot in living body on a base of laying stretching of bellows at a means of running by thinking application of in-tube inspection in living body such as large and small bowels. As a result, an in-tube running robot with about 20 mm in inner diameter capable of running in soft small bowel as well as in hard running tube was developed successfully. After an accident of the Tsuruga nuclear power plant, inspection of a large diameter tube with 76 mm in inner diameter was found to be much important, to begin development of an in-tube running robot for 50 mm class diameter tube. As a result, an in-tube running robot capable of enough holding a micro video camera with about 20 g in mass and showing 4.6 N in tension at more than ten times higher speed of 248 mm/s in no loading state, could be made in trial. Here was reported on a foothold realizable on an in-tube running robot for the 76 mm class large diameter tube to be investigated in future. (G.K.)

  19. MicroComputed Tomography: Methodology and Applications

    International Nuclear Information System (INIS)

    Stock, Stuart R.

    2009-01-01

    Due to the availability of commercial laboratory systems and the emergence of user facilities at synchrotron radiation sources, studies of microcomputed tomography or microCT have increased exponentially. MicroComputed Technology provides a complete introduction to the technology, describing how to use it effectively and understand its results. The first part of the book focuses on methodology, covering experimental methods, data analysis, and visualization approaches. The second part addresses various microCT applications, including porous solids, microstructural evolution, soft tissue studies, multimode studies, and indirect analyses. The author presents a sufficient amount of fundamental material so that those new to the field can develop a relative understanding of how to design their own microCT studies. One of the first full-length references dedicated to microCT, this book provides an accessible introduction to field, supplemented with application examples and color images.

  20. Wavelet Spatial Energy Spectrums Studies on Drag Reduction by Micro-bubble Injection

    International Nuclear Information System (INIS)

    Ling Zhen; Yassin Hassan

    2006-01-01

    In this study, continuous wavelet transforms and spatial correlation techniques are employed to determine the space-localized wavenumber energy spectrum of the velocity signals in turbulent channel flow. The flow conditions correspond to single phase flow and micro-bubbles injected two phase flow. The wavelet energy spectrums demonstrate that the wavenumber (eddy size) content of the velocity signals is not only space-dependent but also micro-bubbles can impact the eddy size content. Visual observations of the wavelet energy spectrum spatial distribution was realized by using Particle Image Velocimetry (PIV) measurement technique. The two phase flow condition corresponds to a drag reduction of 38.4% with void fraction of 4.9%. The present results provide evidence that micro-bubbles in the boundary layer of a turbulent channel flow can help adjust the eddy size distributions near the wall. This can assist in explaining that micro-bubbles are performing as buffers to keep the energy of fluid particles going in stream-wise direction and reducing the energy of fluid particles going in normal direction. (authors)

  1. Failure analysis of the boiler water-wall tube

    OpenAIRE

    S.W. Liu; W.Z. Wang; C.J. Liu

    2017-01-01

    Failure analysis of the boiler water-wall tube is presented in this work. In order to examine the causes of failure, various techniques including visual inspection, chemical analysis, optical microscopy, scanning electron microscopy and energy dispersive spectroscopy were carried out. Tube wall thickness measurements were performed on the ruptured tube. The fire-facing side of the tube was observed to have experienced significant wall thinning. The composition of the matrix material of the tu...

  2. Application of X-ray micro-CT for micro-structural characterization of APCVD deposited SiC coatings on graphite conduit.

    Science.gov (United States)

    Agrawal, A K; Sarkar, P S; Singh, B; Kashyap, Y S; Rao, P T; Sinha, A

    2016-02-01

    SiC coatings are commonly used as oxidation protective materials in high-temperature applications. The operational performance of the coating depends on its microstructure and uniformity. This study explores the feasibility of applying tabletop X-ray micro-CT for the micro-structural characterization of SiC coating. The coating is deposited over the internal surface of pipe structured graphite fuel tube, which is a prototype of potential components of compact high-temperature reactor (CHTR). The coating is deposited using atmospheric pressure chemical vapor deposition (APCVD) and properties such as morphology, porosity, thickness variation are evaluated. Micro-structural differences in the coating caused by substrate distance from precursor inlet in a CVD reactor are also studied. The study finds micro-CT a potential tool for characterization of SiC coating during its future course of engineering. We show that depletion of reactants at larger distances causes development of larger pores in the coating, which affects its morphology, density and thickness. Copyright © 2015 Elsevier Ltd. All rights reserved.

  3. Application of micro-computed tomography to microstructure studies of the medicinal fungus Hericium coralloides.

    Science.gov (United States)

    Pallua, Johannes D; Kuhn, Volker; Pallua, Anton F; Pfaller, Kristian; Pallua, Anton K; Recheis, Wolfgang; Pöder, Reinhold

    2015-01-01

    The potential of 3-D nondestructive imaging techniques such as micro-computed tomography (micro-CT) was evaluated to study morphological patterns of the potential medicinal fungus Hericium coralloides (Basidiomycota). Micro-CT results were correlated with histological information gained from scanning electron microscopy (SEM) and light microscopy (LM). It is demonstrated that the combination of these imaging methods results in a more distinct picture of the morphology of the edible and potentially medicinal Hericium coralloides basidiomata. In addition we have created 3-D reconstructions and visualizations based on micro-CT imagery from a randomly selected part of the upper region of a fresh H. coralloides basidioma: Analyses for the first time allowed an approximation of the evolutionary effectiveness of this bizarrely formed basidioma type in terms of the investment of tissue biomass and its reproductive output (production of basidiospores). © 2015 by The Mycological Society of America.

  4. Magnetic resonance beacon to detect intracellular microRNA during neurogenesis.

    Science.gov (United States)

    Lee, Jonghwan; Jin, Yeon A; Ko, Hae Young; Lee, Yong Seung; Heo, Hyejung; Cho, Sujeong; Kim, Soonhag

    2015-02-01

    Magnetic resonance imaging (MRI) offers great spatial resolution for viewing deep tissues and anatomy. We developed a self-assembling signal-on magnetic fluorescence nanoparticle to visualize intracellular microRNAs (miRNAs or miRs) during neurogenesis using MRI. The self-assembling nanoparticle (miR124a MR beacon) was aggregated by the incubation of three different oligonucleotides: a 3' adaptor, a 5' adaptor, and a linker containing miR124a-binding sequences. The T2-weighted magnetic resonance (MR) signal of the self-assembled nanoparticle was quenched when miR124a was absent from test tubes or was minimally expressed in cells and tissues. When miR124a was present in test tubes or highly expressed in vitro and in vivo during P19 cell neurogenesis, it hybridized with the miR124a MR beacon, causing the linker to detach, resulting in increased signal-on MRI intensity. This MR beacon can be used as a new imaging probe to monitor the miRNA-mediated regulation of cellular processes. Copyright © 2014 Elsevier Ltd. All rights reserved.

  5. Micro-angiographic system using synchrotron radiation and conventional x-ray source for visualizing angiogenic vessels induced by cardiovascular regeneration therapy

    International Nuclear Information System (INIS)

    Mori, H.; Chiku, M.; Nishigami, K.; Tanaka, E.; Kimura, K.; Kawai, T.; Suzuki, K.; Mochizuki, R.; Okawa, Y.

    2004-01-01

    Therapeutic angiogenesis improved critical limb and myocardial ischemia in human, however, angiogenic vessels were not visualized well by conventional angiography, because of its limited spatial resolution of 200 μm. Recently, synchrotron radiation system characterized by high brightness, monochromatic and collimated nature revealed the micro-vessels of heart and lower limb in situ. We developed also an in-house microangiographic system with a relatively low cost. Limb ischemia models were made by ligature of femoral artery and treated by angiogenic growth factor genes and so on. One month after the treatment, we evaluated collateral micro-vessels by using the conventional and micro-angiographic systems. The approach was left femoral artery, and catheter was located in abdominal aorta. Iodine contrast (300 mg/ml) was injected 5 ml by 3 ml/sec with auto-injection system. The imaging was recorded by digital source in 1000 x 1000 pixels. The micro-angiographic system could detect the micro-vessels more precisely than conventional angiographic system and evaluate their function. (author)

  6. Controlled synthesis of colloidal silver nanoparticles in capillary micro-flow reactor

    International Nuclear Information System (INIS)

    He Shengtai; Liu Yulan; Maeda, Hideaki

    2008-01-01

    In this study, using a polytetrafluoroethylene (PTFE) capillary tube as a micro-flow reactor, well-dispersed colloidal silver nanoparticles were controllably synthesized with different flow rates of precursory solution. Scanning transmission electron microscopy images and UV-visible absorbance spectra showed that silver nanoparticles with large size can be prepared with slow flow rate in the PTFE capillary reactor. The effects of tube diameters on the growth of colloidal silver nanoparticles were investigated. Experiment results demonstrated that using tube with small diameter was more propitious for the controllable synthesis of silver nanoparticles with different sizes.

  7. Morphology of Major Stone Types, As Shown by Micro Computed Tomography (micro CT)

    International Nuclear Information System (INIS)

    Jackson, Molly E.; Beuschel, Christian A.; McAteer, James A.; Williams, James C.

    2008-01-01

    Micro CT offers the possibility of providing a non-destructive method of stone analysis that allows visualization of 100% of the stone's volume. For the present study, micro CT analysis was completed on stones of known composition with isotropic voxel sizes of either 7 or 9.1 μm. Each mineral type was distinctive, either by x-ray attenuation values or by morphology. Minor components, such as the presence of apatite in oxalate stones, were easily seen. The analysis of stones by micro CT opens up the possibility of exploring the stone as an encapsulated history of the patient's disease, showing changes in mineral deposition with time.

  8. A model for the Global Quantum Efficiency for a TPB-based wavelength-shifting system used with photomultiplier tubes in liquid argon in MicroBooNE

    Science.gov (United States)

    Pate, S. F.; Wester, T.; Bugel, L.; Conrad, J.; Henderson, E.; Jones, B. J. P.; McLean, A. I. L.; Moon, J. S.; Toups, M.; Wongjirad, T.

    2018-02-01

    We present a model for the Global Quantum Efficiency (GQE) of the MicroBooNE optical units. An optical unit consists of a flat, circular acrylic plate, coated with tetraphenyl butadiene (TPB), positioned near the photocathode of a 20.2-cm diameter photomultiplier tube. The plate converts the ultra-violet scintillation photons from liquid argon into visible-spectrum photons to which the cryogenic phototubes are sensitive. The GQE is the convolution of the efficiency of the plates that convert the 128 nm scintillation light from liquid argon to visible light, the efficiency of the shifted light to reach the photocathode, and the efficiency of the cryogenic photomultiplier tube. We develop a GEANT4-based model of the optical unit, based on first principles, and obtain the range of probable values for the expected number of detected photoelectrons (NPE) given the known systematic errors on the simulation parameters. We compare results from four measurements of the NPE determined using alpha-particle sources placed at two distances from a TPB-coated plate in a liquid argon cryostat test stand. We also directly measured the radial dependence of the quantum efficiency, and find that this has the same shape as predicted by our model. Our model results in a GQE of 0.0055±0.0009 for the MicroBooNE optical units. While the information shown here is MicroBooNE specific, the approach to the model and the collection of simulation parameters will be widely applicable to many liquid-argon-based light collection systems.

  9. CFD modeling and experimental verification of oscillating flow and heat transfer processes in the micro coaxial Stirling-type pulse tube cryocooler operating at 90-170 Hz

    Science.gov (United States)

    Zhao, Yibo; Yu, Guorui; Tan, Jun; Mao, Xiaochen; Li, Jiaqi; Zha, Rui; Li, Ning; Dang, Haizheng

    2018-03-01

    This paper presents the CFD modeling and experimental verifications of oscillating flow and heat transfer processes in the micro coaxial Stirling-type pulse tube cryocooler (MCSPTC) operating at 90-170 Hz. It uses neither double-inlet nor multi-bypass while the inertance tube with a gas reservoir becomes the only phase-shifter. The effects of the frequency on flow and heat transfer processes in the pulse tube are investigated, which indicates that a low enough frequency would lead to a strong mixing between warm and cold fluids, thereby significantly deteriorating the cooling performance, whereas a high enough frequency would produce the downward sloping streams flowing from the warm end to the axis and almost puncturing the gas displacer from the warm end, thereby creating larger temperature gradients in radial directions and thus undermining the cooling performance. The influence of the pulse tube length on the temperature and velocity when the frequencies are much higher than the optimal one are also discussed. A MCSPTC with an overall mass of 1.1 kg is worked out and tested. With an input electric power of 59 W and operating at 144 Hz, it achieves a no-load temperature of 61.4 K and a cooling capacity of 1.0 W at 77 K. The changing tendencies of tested results are in good agreement with the simulations. The above studies will help to thoroughly understand the underlying mechanism of the inertance MCSPTC operating at very high frequencies.

  10. An investigation on compression strength analysis of commercial aluminium tube to aluminium 2025 tube plate by using TIG welding process

    Energy Technology Data Exchange (ETDEWEB)

    Kannan, S., E-mail: kannan.dgl201127@gmail.com [Department of Mechanical Engineering and Mining Machinery Engineering, Indian Institute of Technology (ISM), Dhanbad, Jharkhand, India, 826004 (India); Senthil Kumaran, S., E-mail: sskumaran@ymail.com [Research and Development Center, Department of Mechanical Engineering, RVS Educational Trust' s Group of Institutions, RVS School of Engineering and Technology, Dindigul, Tamilnadu, India, 624005 (India); Kumaraswamidhas, L.A., E-mail: lakdhas1978@gmail.com [Department of Mechanical Engineering and Mining Machinery Engineering, Indian School of Mines University, Dhanbad, Jharkhand, India, 826004 (India)

    2016-05-05

    In this present study, Tungsten inert gas (TIG) welding was applied to weld the dissimilar materials and authenticate the mechanical and metallurgical properties of tube to tube plate made up of commercial aluminium and Al 2025 respectively using an Zirconiated tungsten electrode along with filler material aluminium ER 2219. In total, twenty five pieces has been subjected to compression strength and hardness value to evaluate the optimal joint strength. The three optimization technique has been used in this experiment. Taguchi L{sub 25} orthogonal array is used to identify the most influencing process parameter which affects the joint strength. ANOVA method is measured for both compression strength and hardness to calculate the percentage of contribution for each process parameter. Genetic algorithm is used to validate the results obtained from the both experimental value and optimization value. The micro structural study is depicted the welding joints characterization in between tube to tube plate joints. The radiograph test is conducted to prove the welds are non-defective and no flaws are found during the welding process. The mechanical property of compression strength and hardness has been measured to obtain the optimal joint strength of the welded sample was about 174.846 MPa and 131.364 Hv respectively. - Highlights: • Commercial Al tube and Al 2025 tube plate successfully welded by TIG welding. • Compression strength and hardness value proves to obtain optimal joint strength. • The maximum compression and hardness was achieved in various input parameters.

  11. An investigation on compression strength analysis of commercial aluminium tube to aluminium 2025 tube plate by using TIG welding process

    International Nuclear Information System (INIS)

    Kannan, S.; Senthil Kumaran, S.; Kumaraswamidhas, L.A.

    2016-01-01

    In this present study, Tungsten inert gas (TIG) welding was applied to weld the dissimilar materials and authenticate the mechanical and metallurgical properties of tube to tube plate made up of commercial aluminium and Al 2025 respectively using an Zirconiated tungsten electrode along with filler material aluminium ER 2219. In total, twenty five pieces has been subjected to compression strength and hardness value to evaluate the optimal joint strength. The three optimization technique has been used in this experiment. Taguchi L_2_5 orthogonal array is used to identify the most influencing process parameter which affects the joint strength. ANOVA method is measured for both compression strength and hardness to calculate the percentage of contribution for each process parameter. Genetic algorithm is used to validate the results obtained from the both experimental value and optimization value. The micro structural study is depicted the welding joints characterization in between tube to tube plate joints. The radiograph test is conducted to prove the welds are non-defective and no flaws are found during the welding process. The mechanical property of compression strength and hardness has been measured to obtain the optimal joint strength of the welded sample was about 174.846 MPa and 131.364 Hv respectively. - Highlights: • Commercial Al tube and Al 2025 tube plate successfully welded by TIG welding. • Compression strength and hardness value proves to obtain optimal joint strength. • The maximum compression and hardness was achieved in various input parameters.

  12. Measurement and modelling of a radiofrequency micro-thruster

    International Nuclear Information System (INIS)

    Charles, C; Boswell, R W

    2012-01-01

    A capacitively coupled radiofrequency (rf) (13.56 MHz) cylindrical argon micro-discharge expanding into a larger glass tube is studied by performing optical and electrical measurements over a pressure range 0.3–5 Torr and a rf power range 5–40 W. Measurements of the axial and radial plasma density profiles at the Paschen minimum near 1.5 Torr are used to develop a global model of the discharge and estimate neutral heating from ion–neutral charge exchange collisions for micro-propulsion applications. (fast track communication)

  13. Bronchial intubation could be detected by the visual stethoscope techniques in pediatric patients.

    Science.gov (United States)

    Kimura, Tetsuro; Suzuki, Akira; Mimuro, Soichiro; Makino, Hiroshi; Sato, Shigehito

    2012-12-01

    We created a system that allows the visualization of breath sounds (visual stethoscope). We compared the visual stethoscope technique with auscultation for the detection of bronchial intubation in pediatric patients. In the auscultation group, an anesthesiologist advanced the tracheal tube, while another anesthesiologist auscultated bilateral breath sounds to detect the change and/or disappearance of unilateral breath sounds. In the visualization group, the stethoscope was used to detect changes in breath sounds and/or disappearance of unilateral breath sounds. The distance from the edge of the mouth to the carina was measured using a fiberoptic bronchoscope. Forty pediatric patients were enrolled in the study. At the point at which irregular breath sounds were auscultated, the tracheal tube was located at 0.5 ± 0.8 cm on the bronchial side from the carina. When a detectable change of shape of the visualized breath sound was observed, the tracheal tube was located 0.1 ± 1.2 cm on the bronchial side (not significant). At the point at which unilateral breath sounds were auscultated or a unilateral shape of the visualized breath sound was observed, the tracheal tube was 1.5 ± 0.8 or 1.2 ± 1.0 cm on the bronchial side, respectively (not significant). The visual stethoscope allowed to display the left and the right lung sound simultaneously and detected changes of breath sounds and unilateral breath sound as a tracheal tube was advanced. © 2012 Blackwell Publishing Ltd.

  14. Visualization of diffusion mixing in a micro-mixer with flow paths fabricated by photolithography

    Science.gov (United States)

    Horiuchi, Toshiyuki; Morizane, Yuta

    2017-09-01

    Mixing processes of two liquids were investigated by visualizing the mixing when they were simultaneously injected in a micro-mixer with lithographically fabricated Y-shape flow paths, and the mixing phenomena was analyzed in detail. To visualize the mixing, flows were observed by an optical microscope, and a clearly detectable chemical reaction was utilized. As the two liquids, a transparent aqueous solution of a strong alkali and a phenolphthalein ethanol solution were used. When they were simultaneously injected in Y-shape flow paths of a micro-mixer, they flowed at first in parallel along the joined path as laminar flows. This is because the Reynolds' number became very small caused by the narrow flow-path widths of 50-100 μm. However, because two liquids were always contacted at the boundary, they were gradually mixed by diffusion, and the color of the mixed parts changed to vivid red. For this reason, it was able to measure the diffusion distance from the flow path center. Because the flow speeds were much faster than the diffusion speeds, the area colored in red did not depend on the time but depended on the distance from the joint point. It was known that the distance from the joint point corresponded to the time for mixing the liquids by the diffusion. It was clarified that the diffusion distance x was proportional to the square root of the diffusion time t or the distance from the joint point. The calculated diffusion coefficient D was (0.87-1.00)×10-9 m2/s.

  15. Tube shunt complications and their prevention.

    Science.gov (United States)

    Sarkisian, Steven R

    2009-03-01

    Glaucoma drainage devices (GDDs) have been generally accepted as a treatment of refractory glaucoma. GDDs have their own unique set of complications that are important to evaluate to prevent them. Tube shunts are typically used in eyes with refractory glaucoma. There is increased interest in studying the efficacy of GDDs. Most of the attention has been focused on comparing trabeculectomy with the Baerveldt implant (Advanced Medical Optics, Inc., Santa Anna, California, USA). The other leading implant is the Ahmed Glaucoma Valve. There are several retrospective studies comparing these two devices and a prospective study is ongoing. There is great interest in the complication rate of tube shunts and these have been published both retrospectively and prospectively. Complications such as hypotony, diplopia, strabismus, proptosis, tube erosion, failure, corneal decompensation, endophthalmitis, and visual loss are all important and some have recently been reviewed in the literature. Moreover, the use of glaucoma drainage implants in the pediatric population has been evaluated. Glaucoma drainage implants have been a powerful tool in our surgical fight to prevent blindness; however, they are not without complications or controversy.

  16. Qualitative Research Methods in Visual Communication. Case Study: Visual Networks in the Promotional Videos of the European Year of Volunteering

    Directory of Open Access Journals (Sweden)

    Camelia Cmeciu

    2013-05-01

    Full Text Available European Years are a means of promoting European issues at a macro and micro-level. The objective of this paper is to provide the visual differences in the framing of the issue of volunteering at a European and national level. The approach focuses on a blending of two qualitative research methods in visual communication: ATLAS.ti (computer assisted/ aided qualitative data analysis software and social semiotics. The results of our analysis highlight two network views on volunteering promoted through videos, a salience of transactional processes in the implementation of volunteering at a European and national level, and a classification of various types of social practices specific to Romania. This study provides an insight into the way in which two different qualitative methods may be combined in order to provide a visual representation and interpretation to a European issue.

  17. Failure analysis of the boiler water-wall tube

    Directory of Open Access Journals (Sweden)

    S.W. Liu

    2017-10-01

    Full Text Available Failure analysis of the boiler water-wall tube is presented in this work. In order to examine the causes of failure, various techniques including visual inspection, chemical analysis, optical microscopy, scanning electron microscopy and energy dispersive spectroscopy were carried out. Tube wall thickness measurements were performed on the ruptured tube. The fire-facing side of the tube was observed to have experienced significant wall thinning. The composition of the matrix material of the tube meets the requirements of the relevant standards. Microscopic examinations showed that the spheroidization of pearlite is not very obvious. The failure mechanism is identified as a result of the significant localized wall thinning of the boiler water-wall tube due to oxidation.

  18. Simulasi Thermal Stress Pada Tube Superheater Package Boiler

    OpenAIRE

    Hamdani

    2013-01-01

    This project investigates the thermal stress behavior and the mechanisms of superheater tube failure with experimental method and numerical analysis. First of all the procedures for failure analysis were applied to determine the root cause of them. A visual assessment of boiler critical pressure parts was carried out, and then the failed tube is examined by nondestructive evaluation. For the numerical domain, initially the elastic solution for a superheater tube subjected to an internal press...

  19. A Study on the Structural Integrity Considering the Installation of a Micro-tube Heat Exchanger

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Se Yun; Kim, Tae Jin; Cho, Jong Rae [Korea Maritime and Ocean University, Busan (Korea, Republic of); Jeong, Ho Sung [Pusan National University, Busan (Korea, Republic of)

    2015-04-15

    The objective of this study is to predict the structural characteristics of a heat exchanger mounted on an aircraft engine using finite element analysis. The plastic fracture and life of the heat exchanger were estimated by a thermo-mechanical analysis. Tensile tests were conducted under high temperature conditions (700, 800, 900, 1000 K) using five specimens to obtain the mechanical properties of the Inconel 625 tubes. To assess the structural characteristics of the heat exchanger, the full and partial models were applied under the operating conditions given by the thermo-mechanical and inertial load. As a result, the case, tubesheet, flange, and mounting components have a reasonable safety margin to the allowable stress assuming a fatigue strength of Inconel 625 of 10000 cycles under 1000 K.

  20. A Study on the Structural Integrity Considering the Installation of a Micro-tube Heat Exchanger

    International Nuclear Information System (INIS)

    Oh, Se Yun; Kim, Tae Jin; Cho, Jong Rae; Jeong, Ho Sung

    2015-01-01

    The objective of this study is to predict the structural characteristics of a heat exchanger mounted on an aircraft engine using finite element analysis. The plastic fracture and life of the heat exchanger were estimated by a thermo-mechanical analysis. Tensile tests were conducted under high temperature conditions (700, 800, 900, 1000 K) using five specimens to obtain the mechanical properties of the Inconel 625 tubes. To assess the structural characteristics of the heat exchanger, the full and partial models were applied under the operating conditions given by the thermo-mechanical and inertial load. As a result, the case, tubesheet, flange, and mounting components have a reasonable safety margin to the allowable stress assuming a fatigue strength of Inconel 625 of 10000 cycles under 1000 K

  1. Fabrication of micro metallic valve and pump

    Science.gov (United States)

    Yang, Ming; Kabasawa, Yasunari; Ito, Kuniyoshi

    2010-03-01

    Fabrication of micro devices by using micro metal forming was proposed by the authors. We developed a desktop servo-press machine with precise tooling system. Precise press forming processes including micro forging and micro joining has been carried out in a progressive die. In this study, micro metallic valve and pump were fabricated by using the precise press forming. The components are made of sheet metals, and assembled in to a unit in the progressive die. A micro check-valve with a diameter of 3mm and a length of 3.2mm was fabricated, and the property of flow resistance was evaluated. The results show that the check valve has high property of leakage proof. Since the valve is a unit parts with dimensions of several millimeters, it has advantage to be adapted to various pump design. Here, two kinds of micro pumps with the check-valves were fabricated. One is diaphragm pump actuated by vibration of the diaphragm, and another is tube-shaped pump actuated by resonation. The flow quantities of the pumps were evaluated and the results show that both of the pumps have high pumping performance.

  2. The root caused analysis of leakaged heat exchanger tube

    International Nuclear Information System (INIS)

    Shamsudin, Shaiful Rizam; Salleh, M.A.A. Mohd; Rahmat, Azmi; Anuar, Mohd Arif; Harun, Mohd; Zayid, Hafizal; Noor, Mazlee Mohd

    2015-01-01

    AISI type 316L stainless steel was used as a heat exchanger tube material in an inter-cooler column. After less than a year of operation, severe corrosion failures occurred and a transverse opening leakage was observed on one of the heat exchanger tubes. The failed tube was carefully analyzed using various metallurgical laboratory equipments. The root cause of the tube leakage was believed due to the presence of horizontal micro and macro pores as a hydrogen gas entrapment during casting of the parent ingot. The overlapped and gaping pores formed notch on the shell side of the tube surface, and it increasingly evident when the use of a high-energy water-jet and metal brush as cleaning procedure results in an establishment of pitting type local-action corrosion cells penetrated the tube wall. As a result, corrosive fluid in the tube side dissolved into the cooling water, accelerating the corrosion process.

  3. Hydraulic performance evaluation of pressure compensating (pc) emitters and micro-tubing for drip irrigation system

    International Nuclear Information System (INIS)

    Mangrio, A.G.; Asif, M.; Jahangir, I.

    2013-01-01

    Drip irrigation system is necessary for those areas, where the water scarcity issues are present. The present study was conducted at the field station of Climate Change, Alternate Energy and Water Resources Institute (CAEWRI), National Agricultural Research Center (NARC), Islamabad, during 2013, regarding drip irrigation system. Drip irrigation system depends on uniform emitter application flow. All the emitters were tested and replicated thrice at pressure head (34 to 207Kpa) with an increment of 34 Kpa. The minimum and maximum discharges were 1.32 - 3.52, 3.36 - 5.42, and 43.22 - 100.99 Lph, with an average of 2.42, 4.63 and 73.66 Lph, for Bow Smith, RIS and Micro-tubing, respectively. It indicates that more than 90% of emission uniformity (EU) and uniformity coefficient (CU) for all Emitters, which shows excellent water application with least standard deviation, ranging 0.12 to 2.37, throughout the operating pressure heads in all emitters. An average coefficient of variation (CV) of all emitters were behaving less than 0.07, indicating an excellent class at all operating pressure heads between 34 to 207 Kpa. Moreover, the relationship of discharge and pressure of emitters indicates that discharge increased with the increase of pressure head. The Q-H curve plays key role in the selection of emitters. (author)

  4. The Study of Heat Treatment Effects on Chromium Carbide Precipitation of 35Cr-45Ni-Nb Alloy for Repairing Furnace Tubes

    Directory of Open Access Journals (Sweden)

    Nakarin Srisuwan

    2016-01-01

    Full Text Available This paper presents a specific kind of failure in ethylene pyrolysis furnace tubes. It considers the case in which the tubes made of 35Cr-45Ni-Nb high temperature alloy failed to carburization, causing creep damage. The investigation found that used tubes became difficult to weld repair due to internal carburized layers of the tube. The microstructure and geochemical component of crystallized carbide at grain boundary of tube specimens were characterized by X-ray diffractometer (XRD, scanning electron microscopy (SEM with back-scattered electrons mode (BSE, and energy dispersive X-ray spectroscopy (EDS. Micro-hardness tests was performed to determine the hardness of the matrix and the compounds of new and used tube material. The testing result indicated that used tubes exhibited a higher hardness and higher degree of carburization compared to those of new tubes. The microstructure of used tubes also revealed coarse chromium carbide precipitation and a continuous carbide lattice at austenite grain boundaries. However, thermal heat treatment applied for developing tube weld repair could result in dissolving or breaking up chromium carbide with a decrease in hardness value. This procedure is recommended to improve the weldability of the 35Cr-45Ni-Nb used tubes alloy.

  5. Heat transfer and flow pattern during two-phase flow boiling of R-134a in horizontal smooth and microfin tubes

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Minghuei; Lin, Tsunkuo; Tseng, Chyuanchyi [National Sun Yat Sen Univ., Taiwan (China). Dept. of Mechanical Engineering

    2002-09-01

    Flow pattern and heat transfer during evaporation in a 10.7 mm diameter smooth tube and a micro-fin tube are presented. The tubes were tested in the ranges of mass flux between 163 and 408 kg m{sup -2}s{sup -1} and heat flux between 2200 and 56 000 W m{sup -2}. The evaporation temperature was 6{sup o}C. Flow maps for both the tubes are plotted in the coordinates of mass flux and vapor quality. The relations of flow pattern and local heat transfer coefficient are discussed. The heat transfer coefficients for intermittent and annular flows in both the smooth tube and the micro-fin tube are shown to agree well with Gungor and Winterton's correlation with modified constants. (author)

  6. Metallurgical Analysis of Cracks Formed on Coal Fired Boiler Tube

    Science.gov (United States)

    Kishor, Rajat; Kyada, Tushal; Goyal, Rajesh K.; Kathayat, T. S.

    2015-02-01

    Metallurgical failure analysis was carried out for cracks observed on the outer surface of a boiler tube made of ASME SA 210 GR A1 grade steel. The cracks on the surface of the tube were observed after 6 months from the installation in service. A careful visual inspection, chemical analysis, hardness measurement, detailed microstructural analysis using optical and scanning electron microscopy coupled with energy dispersive X-ray spectroscopy were carried out to ascertain the cause for failure. Visual inspection of the failed tube revealed the presence of oxide scales and ash deposits on the surface of the tube exposed to fire. Many cracks extending longitudinally were observed on the surface of the tube. Bulging of the tube was also observed. The results of chemical analysis, hardness values and optical micrographs did not exhibit any abnormality at the region of failure. However, detailed SEM with EDS analysis confirmed the presence of various oxide scales. These scales initiated corrosion at both the inner and outer surfaces of the tube. In addition, excessive hoop stress also developed at the region of failure. It is concluded that the failure of the boiler tube took place owing to the combined effect of the corrosion caused by the oxide scales as well as the excessive hoop stress.

  7. A thin-lip rupture of carbon steel superheater boiler tube

    International Nuclear Information System (INIS)

    Khalil, E.O.; Alzoye, K.S.; Elwaer, A.M.

    1993-01-01

    A ruptured A 42 medium carbon steel tube was collected by the engineering department in one of our steam power stations. Inspection of ruptured tube revealed a thin - lip fracture with brownish thin layer of oxide film on inner tube surfaces. There was no evidence of pitting, the outer surfaces of the tube exhibited a general oxidized conditions. A micro section taken near the fracture surface consists of ferrite and martensite, the amount of martensite decreased as we away from the fracture surface. Presence of martensite phase in the microstructure indicates that the tube material has been overheated. An erosion corrosion mechanism in conjunction with overheated. An erosion corrosion mechanism in conjunction with overheating resulted in strength deterioration with consequent premature failure. 4 fig., 1 tab

  8. In-line phase contrast micro-CT reconstruction for biomedical specimens.

    Science.gov (United States)

    Fu, Jian; Tan, Renbo

    2014-01-01

    X-ray phase contrast micro computed tomography (micro-CT) can non-destructively provide the internal structure information of soft tissues and low atomic number materials. It has become an invaluable analysis tool for biomedical specimens. Here an in-line phase contrast micro-CT reconstruction technique is reported, which consists of a projection extraction method and the conventional filter back-projection (FBP) reconstruction algorithm. The projection extraction is implemented by applying the Fourier transform to the forward projections of in-line phase contrast micro-CT. This work comprises a numerical study of the method and its experimental verification using a biomedical specimen dataset measured at an X-ray tube source micro-CT setup. The numerical and experimental results demonstrate that the presented technique can improve the imaging contrast of biomedical specimens. It will be of interest for a wide range of in-line phase contrast micro-CT applications in medicine and biology.

  9. An experimental investigation of the effects of spiral angle on the evaporation heat transfer coefficients in microfin tubes with visualization technique

    Science.gov (United States)

    Oh, Se-Yoon

    A smooth tube and five microfin tubes were tested, and evaporation heat transfer coefficients were measured and compared for mass fluxes, 50, 100 and 200 kg/m2 s, and heat fluxes, 5, 10 and 20 kW/m 2, with Refrigerant 134a as a working fluid. The evaporation heat transfer coefficients at quality 0.5 were compared among the smooth and five microfin tubes with spiral angles 6, 12, 18, 25 and 44 degrees. The effect of the spiral angle on the heat transfer coefficients was examined. It was found that the optimal spiral angle where the maximum heat transfer coefficient occurs, mainly depends on mass flux. The optimal spiral angle was 18 degrees for G=50 kg/m2 s, and 6 degrees for G=100 and 200 kg/m 2 s. A borescope was used to visualize the flow on the inside wall of test tubes. The purpose was to find out the effect of the grooves on the liquid flow in microfin tubes and to explain the mechanism of heat transfer enhancement. Temperatures on the tube wall were measured at the same axial location as the imaging sensor of the borescope, and were related to the behavior of the liquid flow on the inside wall of the tubes. The liquid flow in the grooves on the wall was found to be the most important factor in enhancing heat transfer coefficients. The liquid flowed upward along the grooves and covered the upper inside wall of the microfin tubes at G=50 kg/m2 s. When heat flux increases, the liquid flow was found at a higher position. Both liquid viscosity and surface tension decrease, when temperature increases. Thus, the lower viscosity at higher heat flux facilitated the upward motion of the liquid flow in the grooves, so that the momentum force as well as the capillary effect was found to push the liquid along the grooves.* *A CD is included with dissertation containing video clips in avi format which can be viewed with media player.

  10. Autonomous Micro-Air-Vehicle Control Based on Visual Sensing for Odor Source Localization

    Directory of Open Access Journals (Sweden)

    Kenzo Kurotsuchi

    2017-07-01

    Full Text Available In this paper, we propose a novel control method for autonomous-odor-source localization using visual and odor sensing by micro air vehicles (MAVs. Our method is based on biomimetics, which enable highly autonomous localization. Our method does not need any instruction signals, including even global positioning system (GPS signals. An experimenter simply blows a whistle, and the MAV will then start to hover, to seek an odor source, and to keep hovering near the source. The GPS-signal-free control based on visual sense enables indoor/underground use. Moreover, the MAV is light-weight (85 grams and does not cause harm to others even if it accidentally falls. Experiments conducted in the real world were successful in enabling odor source localization using the MAV with a bio-inspired searching method. The distance error of the localization was 63 cm, more accurate than the target distance of 120 cm for individual identification. Our odor source localization is the first step to a proof of concept for a danger warning system. These localization experiments were the first step to a proof of concept for a danger warning system to enable a safer and more secure society.

  11. Heat transfer with geometric shape of micro-fin tubes (I) - Condensing heat transfer

    Energy Technology Data Exchange (ETDEWEB)

    Kwak, K M; Chang, J S; Bai, C H; Chung, M [Yeungnam University, Kyungsan (Korea)

    1999-11-01

    To examine the enhancement mechanism of condensing heat transfer through microfin tube, the condensation experiments with refrigerant HCFC 22 are performed using 4 and 6 kinds of microfin tubes with outer diameter of 9.52 mm and 7.0 mm, respectively. Used microfin tubes have different shape and number of fins with each other. The main heat transfer enhancement mechanism is known to be the enlargement of heat transfer area and turbulence promotion. Together with these main factors, we can find other enhancement factors by the experimental data, which are the overflow of the refrigerant over the microfin and microfin arrangement. The overflow of the refrigerant over the microfin can be analyzed by the geometric shape of the microfin. microfin tubes having a shape which can give much overflow over the microfin show large condensing heat transfer coefficients. The effect of microfin arrangement is related to the heat transfer resistance of liquid film of refrigerant. The condensing heat transfer coefficients are high for the microfin tube with even distribution of liquid film. 17 refs., 14 figs., 3 tabs.

  12. Design of large-format X-ray framing image tube

    International Nuclear Information System (INIS)

    Zong Fangke; Yang Qinlao; Gu Li; Li Xiang; Zhang Jingjin

    2012-01-01

    An implementation method of large-format framing image tube is proposed. An electrostatic focusing image tube with large input photocathode and small output image is designed. Coupling with common small-format microchannel plate (MCP) gated framing unit, image gating and enhancement can be realized. Compared to the tube with large-format MCP, this kind of framing tube avoids the high manufacturing cost of lager-format MCP and overcomes the transmission voltage loss and gain uniformity caused by long micro strips. The framing image tube has an effective input working diameter of 100 mm, an output image diameter of 40 mm, and a magnification of 0.4. The centre spatial resolution is 14.4 lp/mm, the marginal spatial resolution is 11.2 lp/mm, and the the geometric distortion is less than 15%. The framing characteristics is determined by the MCP framing unit. This method is an effective way for expanding the work area of framing image tubes. (authors)

  13. Jose Cabrera (Zorita) tube examination

    International Nuclear Information System (INIS)

    Kuchirka, P.J.

    1986-01-01

    Jose Cabrera (Zorita) tube examination procedures are discussed. This plant continues to use phosphate water chemistry (sodium/phosphate ratio = 2.1). Three hot leg tube segments were pulled from the Jose Cabera (Zorita) plant in 1985. One tube had a field EC indication on the OD at the first tube support plate and the other two had field EC indications on their ID about 3 inches above the bottom of the tube sheet. All three tubes were initially sent to Battelle for preliminary NDE and decontamination. Segments of two tubes were sent to Westinghouse for destructive examination. The results of the laboratory eddy current and radiographic examinations are given. The results of the visual examinations are also given. The tube with OD indications was destructively examined and shallow intergranular pitting and intergranular attack, up to 2 mils deep, were found on the OD in the tube sheet region. Local areas of IGA, up to 5 mils deep, were found on the OD within the tube support plate region. A summary of this information together with supporting micrographs is given. It was hypothesized that a caustic crevice environment was the cause of this mild degradation. Shallow areas of thinning or wastage, up to 3 mils, were found just above the top of the tube sheet in the sludge pile region. Even more shallow wastage was found at the edges of support plate locations. This wastage is believed to be the remnant of early plant chemistry when a higher sodium/phosphate ratio and higher phosphate concentration were allowed

  14. Elevated temperature failures in boiler tubes - case studies

    International Nuclear Information System (INIS)

    Gowrisankar, I.; Bandyopadhyay, G.

    1989-01-01

    Metallurgical investigation of boiler tube failures enables identification of failure mechanisms and the underlying cause related to boiler conditions. Some case studies in short term overheating, prolonged overheating and low cycle fatigue failures in boiler tubes are discussed. (author)

  15. Hierarchically structured nanoporous carbon tubes for high pressure carbon dioxide adsorption

    Directory of Open Access Journals (Sweden)

    Julia Patzsch

    2017-05-01

    Full Text Available Mesoscopic, nanoporous carbon tubes were synthesized by a combination of the Stoeber process and the use of electrospun macrosized polystyrene fibres as structure directing templates. The obtained carbon tubes have a macroporous nature characterized by a thick wall structure and a high specific surface area of approximately 500 m²/g resulting from their micro- and mesopores. The micropore regime of the carbon tubes is composed of turbostratic graphitic areas observed in the microstructure. The employed templating process was also used for the synthesis of silicon carbide tubes. The characterization of all porous materials was performed by nitrogen adsorption at 77 K, Raman spectroscopy, infrared spectroscopy, thermal gravimetric analysis (TGA, scanning electron microscopy (SEM as well as transmission electron microscopy (TEM. The adsorption of carbon dioxide on the carbon tubes at 25 °C at pressures of up to 30 bar was studied using a volumetric method. At 26 bar, an adsorption capacity of 4.9 mmol/g was observed. This is comparable to the adsorption capacity of molecular sieves and vertically aligned carbon nanotubes. The high pressure adsorption process of CO2 was found to irreversibly change the microporous structure of the carbon tubes.

  16. Origami tubes with reconfigurable polygonal cross-sections.

    Science.gov (United States)

    Filipov, E T; Paulino, G H; Tachi, T

    2016-01-01

    Thin sheets can be assembled into origami tubes to create a variety of deployable, reconfigurable and mechanistically unique three-dimensional structures. We introduce and explore origami tubes with polygonal, translational symmetric cross-sections that can reconfigure into numerous geometries. The tubular structures satisfy the mathematical definitions for flat and rigid foldability, meaning that they can fully unfold from a flattened state with deformations occurring only at the fold lines. The tubes do not need to be straight and can be constructed to follow a non-linear curved line when deployed. The cross-section and kinematics of the tubular structures can be reprogrammed by changing the direction of folding at some folds. We discuss the variety of tubular structures that can be conceived and we show limitations that govern the geometric design. We quantify the global stiffness of the origami tubes through eigenvalue and structural analyses and highlight the mechanical characteristics of these systems. The two-scale nature of this work indicates that, from a local viewpoint, the cross-sections of the polygonal tubes are reconfigurable while, from a global viewpoint, deployable tubes of desired shapes are achieved. This class of tubes has potential applications ranging from pipes and micro-robotics to deployable architecture in buildings.

  17. Origami tubes with reconfigurable polygonal cross-sections

    Science.gov (United States)

    Filipov, E. T.; Paulino, G. H.; Tachi, T.

    2016-01-01

    Thin sheets can be assembled into origami tubes to create a variety of deployable, reconfigurable and mechanistically unique three-dimensional structures. We introduce and explore origami tubes with polygonal, translational symmetric cross-sections that can reconfigure into numerous geometries. The tubular structures satisfy the mathematical definitions for flat and rigid foldability, meaning that they can fully unfold from a flattened state with deformations occurring only at the fold lines. The tubes do not need to be straight and can be constructed to follow a non-linear curved line when deployed. The cross-section and kinematics of the tubular structures can be reprogrammed by changing the direction of folding at some folds. We discuss the variety of tubular structures that can be conceived and we show limitations that govern the geometric design. We quantify the global stiffness of the origami tubes through eigenvalue and structural analyses and highlight the mechanical characteristics of these systems. The two-scale nature of this work indicates that, from a local viewpoint, the cross-sections of the polygonal tubes are reconfigurable while, from a global viewpoint, deployable tubes of desired shapes are achieved. This class of tubes has potential applications ranging from pipes and micro-robotics to deployable architecture in buildings. PMID:26997894

  18. Catalyzed Combustion In Micro-Propulsion Devices: Project Status

    Science.gov (United States)

    Sung, C. J.; Schneider, S. J.

    2003-01-01

    the basic units, or in a rapid sequence in order to provide gradual but steady low-g acceleration. These arrays of micro-propulsion systems would offer unprecedented flexibility and redundancy for satellite propulsion and reaction control for launch vehicles. A high-pressure bi-propellant micro-rocket engine is already being developed using MEMS technology. High pressure turbopumps and valves are to be incorporated onto the rocket chip . High pressure combustion of methane and O2 in a micro-combustor has been demonstrated without catalysis, but ignition was established with a spark. This combustor has rectangular dimensions of 1.5 mm by 8 mm (hydraulic diameter 3.9 mm) and a length of 4.5 mm and was operated at 1250 kPa with plans to operate it at 12.7 MPa. These high operating pressures enable the combustion process in these devices, but these pressures are not practical for pressure fed satellite propulsion systems. Note that the use of these propellants requires an ignition system and that the use of a spark would impose a size limitation to this micro-propulsion device because the spark unit cannot be shrunk proportionately with the thruster. Results presented in this paper consist of an experimental evaluation of the minimum catalyst temperature for initiating/supporting combustion in sub-millimeter diameter tubes. The tubes are resistively heated and reactive premixed gases are passed through the tubes. Tube temperature and inlet pressure are monitored for an indication of exothermic reactions and composition changes in the gases.

  19. Advances in direct radiographic magnification technique: First studies with a 1μ focal spot tube

    International Nuclear Information System (INIS)

    Huettenbrink, K.B.; Schadel, A.

    1986-01-01

    A direct radiographic enlargement technique mainly depends on the size of the focal spot. Up to now, its reduction was limited for physical reasons; therefore only minor degrees of magnification were applicable. With the new 1 μ focal spot tube, structures of microscopic dimensions can be visualized for the first time in a direct radiographic magnification of up to 100 diameters. First studies in isolated middle ear ossicles and a phantom soft-tissue-skull are demonstrated. Clinical usefullness seems to be limited, whereas its application for experimental research looks promising. (orig.) [de

  20. Study on corrosion of thermal power plant condenser tubes

    Energy Technology Data Exchange (ETDEWEB)

    Mohammadi, Abdolreza Rashidi; Zhaam, Ali Akbar [Niroo Research Institute, end of Poonak Bakhtari blvd., Shahrak Ghods, Tehran (Iran)

    2004-07-01

    The aim of this investigation is to study kinds of corrosion mechanisms in thermal power plant condenser tubes. Condenser is a shell and tube heat exchanger in which cooling water flows through its tubes. While the steam from low pressure turbine passes within condenser tubes, it is condensed by cooling water. The exhausted steam from low pressure turbine is condensed on external surface of condenser tubes and heat is transferred to cooling water which flow into tubes. Tubes composition is usually copper-based alloys, stainless steel or titanium. Annual damages due to corrosion cause much cost for replacement and repairing metallic equipment and installations in electric power industry. Because of existence of different contaminants in water and steam cycle, condenser tubes surfaces are exposed to corrosion. Contaminants like oxygen, carbon dioxide, chloride ion and ammonia in water and steam cycle originate several damages such as pitting and crevice corrosion, erosion, galvanic attack, SCC, condensed corrosion, de-alloying in thermal power plant condenser. The paper first states how corrosion damage takes place in condensers and then introduces types of usual alloys used in condensers and also their corrosion behavior. In continuation, a brief explanation is presented about kinds of condenser failures due to corrosion. Then, causes and locations of different mechanisms of corrosion events on condenser tubes and effects of different parameters such as composition, temperature, chloride and sulfide ion concentration, pH, water velocity and biological precipitation are examined and finally protection methods are indicated. Also some photos of tubes specimens related to power plants are studied and described in each case of mentioned mechanisms. (authors)

  1. The application of micro UAV in construction project

    Science.gov (United States)

    Kaamin, Masiri; Razali, Siti Nooraiin Mohd; Ahmad, Nor Farah Atiqah; Bukari, Saifullizan Mohd; Ngadiman, Norhayati; Kadir, Aslila Abd; Hamid, Nor Baizura

    2017-10-01

    In every outstanding construction project, there is definitely have an effective construction management. Construction management allows a construction project to be implemented according to plan. Every construction project must have a progress development works that is usually created by the site engineer. Documenting the progress of works is one of the requirements in construction management. In a progress report it is necessarily have a visual image as an evidence. The conventional method used for photographing on the construction site is by using common digital camera which is has few setback comparing to Micro Unmanned Aerial Vehicles (UAV). Besides, site engineer always have a current issues involving limitation of monitoring on high reach point and entire view of the construction site. The purpose of this paper is to provide a concise review of Micro UAV technology in monitoring the progress on construction site through visualization approach. The aims of this study are to replace the conventional method of photographing on construction site using Micro UAV which can portray the whole view of the building, especially on high reach point and allows to produce better images, videos and 3D model and also facilitating site engineer to monitor works in progress. The Micro UAV was flown around the building construction according to the Ground Control Points (GCPs) to capture images and record videos. The images taken from Micro UAV have been processed generate 3D model and were analysed to visualize the building construction as well as monitoring the construction progress work and provides immediate reliable data for project estimation. It has been proven that by using Micro UAV, a better images and videos can give a better overview of the construction site and monitor any defects on high reach point building structures. Not to be forgotten, with Micro UAV the construction site progress is more efficiently tracked and kept on the schedule.

  2. Four-dimensional microscope- integrated optical coherence tomography to enhance visualization in glaucoma surgeries.

    Science.gov (United States)

    Pasricha, Neel Dave; Bhullar, Paramjit Kaur; Shieh, Christine; Viehland, Christian; Carrasco-Zevallos, Oscar Mijail; Keller, Brenton; Izatt, Joseph Adam; Toth, Cynthia Ann; Challa, Pratap; Kuo, Anthony Nanlin

    2017-01-01

    We report the first use of swept-source microscope-integrated optical coherence tomography (SS-MIOCT) capable of live four-dimensional (4D) (three-dimensional across time) imaging intraoperatively to directly visualize tube shunt placement and trabeculectomy surgeries in two patients with severe open-angle glaucoma and elevated intraocular pressure (IOP) that was not adequately managed by medical intervention or prior surgery. We performed tube shunt placement and trabeculectomy surgery and used SS-MIOCT to visualize and record surgical steps that benefitted from the enhanced visualization. In the case of tube shunt placement, SS-MIOCT successfully visualized the scleral tunneling, tube shunt positioning in the anterior chamber, and tube shunt suturing. For the trabeculectomy, SS-MIOCT successfully visualized the scleral flap creation, sclerotomy, and iridectomy. Postoperatively, both patients did well, with IOPs decreasing to the target goal. We found the benefit of SS-MIOCT was greatest in surgical steps requiring depth-based assessments. This technology has the potential to improve clinical outcomes.

  3. Heat transfer and pressure drop in a tube bank inclined with respect to the flow

    Energy Technology Data Exchange (ETDEWEB)

    Yanez Moreno, A.A.

    1985-01-01

    This research is intended to lend understanding and to quantify the heat-transfer and fluid-flow characteristics for yawed tube banks in both staggered and in-line arrays. The investigated range of yaw angle was from 90 (crossflow) to 45/sup 0/, while the freestream Reynolds number (based on the tube diameter) ranged between 7000 and 45,000. The transverse and longitudinal center-to-center distances between the tubes were S/sub T//D = S/sub L//D = 2, respectively. The heat-transfer experiments were carried out on a row-by-row basis. Pressure drop measurements were made not only upstream and downstream of the tube bank but also within it. The patterns of fluid flow adjacent to the tubes were visualized using the oil-lampblack technique. A detailed study was carried out to determine the heat-transfer characteristics of a yawed single cylinder. The yaw angle range was between 90 and 30/sup 0/, and flow visualization was also performed. The pressure measurements showed that the overall dimensionless pressure drop for the staggered array is higher than that for the in-line array for a given Reynolds number or yaw. The flow-visualization patterns showed that the boundary layer separation depends on the yaw angle. For the single cylinder, the Nusselt number varied with the yaw angle in an undulating manner and did not correlate with the Independence Principle.

  4. Micro-particle transporting system using galvanotactically stimulated apo-symbiotic cells of Paramecium bursaria.

    Science.gov (United States)

    Furukawa, Shunsuke; Karaki, Chiaki; Kawano, Tomonori

    2009-01-01

    It is well known that Paramecium species including green paramecia (Paramecium bursaria) migrate towards the anode when exposed to an electric field in a medium. This type of a cellular movement is known as galvanotaxis. Our previous study revealed that an electric stimulus given to P bursaria is converted to a galvanotactic cellular movement by involvement of T-type calcium channel on the plasma membrane [Aonuma et al. (2007), Z. Naturforsch. 62c, 93-102]. This phenomenon has attracted the attention of bioengineers in the fields of biorobotics or micro-robotics in order to develop electrically controllable micromachineries. Here, we demonstrate the galvanotactic controls of the cellular migration of P bursaria in capillary tubes (diameter, 1-2 mm; length, 30-240 mm). Since the Paramecium cells take up particles of various sizes, we attempted to use the electrically stimulated cells of P bursaria as the vehicle for transportation of micro-particles in the capillary system. By using apo-symbiotic cells of P bursaria obtained after forced removal of symbiotic algae, the uptake of the particles could be maximized and visualized. Then, electrically controlled transportations of particle-filled apo-symbiotic P bursaria cells were manifested. The particles transported by electrically controlled cells (varying in size from nm to /m levels) included re-introduced green algae, fluorescence-labeled polystyrene beads, magnetic microspheres, emerald green fluorescent protein (EmGFP)-labeled cells of E. coli, Indian ink, and crystals of zeolite (hydrated aluminosilicate minerals with a micro-porous structure) and some metal oxides. Since the above demonstrations were successful, we concluded that P bursaria has a potential to be employed as one of the micro-biorobotic devices used in BioMEMS (biological micro-electro-mechanical systems).

  5. Fabrication of micro T-shaped tubular components by hydroforming process

    Science.gov (United States)

    Manabe, Ken-ichi; Itai, Kenta; Tada, Kazuo

    2017-10-01

    This paper deals with a T-shape micro tube hydroforming (MTHF) process for 500 µm outer diameter copper microtube. The MTHF experiments were carried out using a MTHF system utilizing ultrahigh pressure. The fundamental micro hydroforming characteristics as well as forming limits are examined experimentally and numerically. From the results, a process window diagram for micro T-shape hydroforming process is created, and a suitable "success" region is revealed.

  6. Micro Coriolis Gas Density Sensor

    NARCIS (Netherlands)

    Sparreboom, Wouter; Ratering, Gijs; Kruijswijk, Wim; van der Wouden, E.J.; Groenesteijn, Jarno; Lötters, Joost Conrad

    2017-01-01

    In this paper we report on gas density measurements using a micro Coriolis sensor. The technology to fabricate the sensor is based on surface channel technology. The measurement tube is freely suspended and has a wall thickness of only 1 micron. This renders the sensor extremely sensitive to changes

  7. Vortex rope instabilities in a model of conical draft tube

    Science.gov (United States)

    Skripkin, Sergey; Tsoy, Mikhail; Kuibin, Pavel; Shtork, Sergey

    2017-10-01

    We report on experimental studies of the formation of vortex ropes in a laboratory simplified model of hydroturbine draft tube. Work is focused on the observation of various flow patterns at the different rotational speed of turbine runner at fixed flow rate. The measurements involve high-speed visualization and pressure pulsations recordings. Draft tube wall pressure pulsations are registered by pressure transducer for different flow regimes. Vortex rope precession frequency were calculated using FFT transform. The experiments showed interesting features of precessing vortex rope like twin spiral and formation of vortex ring.

  8. Vortex rope instabilities in a model of conical draft tube

    Directory of Open Access Journals (Sweden)

    Skripkin Sergey

    2017-01-01

    Full Text Available We report on experimental studies of the formation of vortex ropes in a laboratory simplified model of hydroturbine draft tube. Work is focused on the observation of various flow patterns at the different rotational speed of turbine runner at fixed flow rate. The measurements involve high-speed visualization and pressure pulsations recordings. Draft tube wall pressure pulsations are registered by pressure transducer for different flow regimes. Vortex rope precession frequency were calculated using FFT transform. The experiments showed interesting features of precessing vortex rope like twin spiral and formation of vortex ring.

  9. Investigation into Cause of High Temperature Failure of Boiler Superheater Tube

    Science.gov (United States)

    Ghosh, D.; Ray, S.; Roy, H.; Shukla, A. K.

    2015-04-01

    The failure of the boiler tubes occur due to various reasons like creep, fatigue, corrosion and erosion. This paper highlights a case study of typical premature failure of a final superheater tube of 210 MW thermal power plant boiler. Visual examination, dimensional measurement, chemical analysis, oxide scale thickness measurement, microstructural examination are conducted as part of the investigations. Apart from these investigations, sulfur print, Energy Dispersive spectroscopy (EDS) and X ray diffraction analysis (XRD) are also conducted to ascertain the probable cause of failure of final super heater tube. Finally it has been concluded that the premature failure of the super heater tube can be attributed to the combination of localized high tube metal temperature and loss of metal from the outer surface due to high temperature corrosion. The corrective actions have also been suggested to avoid this type of failure in near future.

  10. Experimental study of air-cooled water condensation in slightly inclined circular tube using infrared temperature measurement technique

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyungdae [Nuclear Engineering Department, Kyung Hee University, Yongin (Korea, Republic of); Kwon, Tae-Soon [Korea Atomic Energy Research Institute, Daedeok-daero 989-111, Yuseong-gu, Daejeon 305-353 (Korea, Republic of); Kim, Dong Eok, E-mail: dekim@knu.ac.kr [Department of Precision Mechanical Engineering, Kyungpook National University, Sangju (Korea, Republic of)

    2016-11-15

    Highlights: • Air-cooled condensation experiments in an inclined Pyrex glass tube were performed. • High-resolution wall temperature data and flow regime formations could be obtained. • The local heat flux was strongly dependent on the air-side heat transfer. • A CFD analysis was conducted for calculating the local heat flux distribution. - Abstract: This study presents the results of an investigation of the air-cooled water condensation heat transfer characteristics inside a slightly inclined circular tube made of transparent Pyrex glass. The high-resolution wall temperature data and stratified film formations could be obtained with the assistance of an infrared (IR) thermometry technique and side-view visualization using a CCD camera. In all experimental cases, the condensation flow patterns were in the fully-stratified flow region. In addition, the experimentally measured void fraction corresponded well with the logarithmic mean void fraction model. The local temperature differences in the cooling air flow across the condenser tube and high-resolution temperature profiles on the tube’s outer wall were obtained in the experimental measurements. Under the experimental conditions of this study, the local heat flux distributions in the longitudinal direction of the test tube were strongly dependent on the cooling air velocity. And, with the help of IR thermometry, the tube outer wall temperature data at 45 local points could be measured. From the data, the asymmetry distribution of the local wall temperatures and the accurate location of the transition from two-phase mixture to single phase liquid inside the tube could be obtained. Also, the analysis of the thermal resistances by condensation, wall conduction and air convection showed that the air convective heat transfer behavior can play a dominant role to the local heat transfer characteristics. Finally, in order to obtain the local heat flux distribution along the tube’s outer wall, a two

  11. Direct ophthalmoscopy on YouTube

    DEFF Research Database (Denmark)

    Borgersen, Nanna Jo; Henriksen, Mikael Johannes Vuokko; Konge, Lars

    2016-01-01

    BACKGROUND: Direct ophthalmoscopy is well-suited for video-based instruction, particularly if the videos enable the student to see what the examiner sees when performing direct ophthalmoscopy. We evaluated the pedagogical effectiveness of instructional YouTube videos on direct ophthalmoscopy...... in general. We then systematically searched YouTube. Two authors reviewed eligible videos to assess eligibility and extract data on video statistics, content, and approach to visualization. Correlations between video statistics and contents were investigated using two-tailed Spearman's correlation. RESULTS...... the patient and how to examine the fundus. Time spent on fundus examination correlated with the number of views per week (Spearman's ρ=0.53; P=0.029). CONCLUSION: Videos may help overcome the pedagogical issues in teaching direct ophthalmoscopy; however, the few available videos on YouTube fail to address...

  12. Critical heat flux on micro-structured zircaloy surfaces for flow boiling of water at low pressures

    International Nuclear Information System (INIS)

    Haas, C.; Miassoedov, A.; Schulenberg, T.; Wetzel, T.

    2012-01-01

    The influence of surface structure on critical heat flux for flow boiling of water was investigated for Zircaloy tubes in a vertical annular test section. The objectives were to find suitable surface modification processes for Zircaloy tubes and to test their critical heat flux performance in comparison to the smooth tube. Surface structures with micro-channels, porous layer, oxidized layer, and elevations in micro- and nano-scale were produced on a section of a Zircaloy cladding tube. These modified tubes were tested in an internally heated vertical annulus with a heated length of 326 mm and an inner and outer diameter of 9.5 and 18 mm. The experiments were performed with mass fluxes of 250 and 400 kg/(m 2 s), outlet pressures between 120 and 300 kPa, and constant inlet subcooling enthalpy of 167 kJ/kg. Only a small influence of modified surface structures on critical heat flux was observed for the pressure of 120 kPa in the present test section geometry. However, with increasing pressure the critical heat flux could increase up to 29% using the surface structured tubes with micro-channels, porous and oxidized layers. Capillary effects and increased nucleation site density are assumed to improve the critical heat flux performance. (authors)

  13. Comparative study of linear and nonlinear ultrasonic techniques for evaluation thermal damage of tube like structures

    International Nuclear Information System (INIS)

    Li, Weibin; Cho, Younho; Li, Xianqiang

    2013-01-01

    Ultrasonic guided wave techniques have been widely used for long range nondestructive detection in tube like structures. The present paper investigates the ultrasonic linear and nonlinear parameters for evaluating the thermal damage in aluminum pipe. Specimens were subjected to thermal loading. Flexible polyvinylidene fluoride (PVDF) comb transducers were used to generate and receive the ultrasonic waves. The second harmonic wave generation technique was used to check the material nonlinearity change after different heat loadings. The conventional linear ultrasonic approach based on attenuation was also used to evaluate the thermal damages in specimens. The results show that the proposed experimental setup is viable to assess the thermal damage in an aluminum pipe. The ultrasonic nonlinear parameter is a promising candidate for the prediction of micro damages in a tube like structure

  14. Study of colloids transport during two-phase flow using a novel polydimethylsiloxane micro-model.

    Science.gov (United States)

    Zhang, Qiulan; Karadimitriou, N K; Hassanizadeh, S M; Kleingeld, P J; Imhof, A

    2013-07-01

    As a representation of a porous medium, a closed micro-fluidic device made of polydimethylsiloxane (PDMS), with uniform wettability and stable hydrophobic properties, was designed and fabricated. A flow network, with a mean pore size of 30 μm, was formed in a PDMS slab, covering an area of 1 mm × 10 mm. The PDMS slab was covered and bonded with a 120-μm-thick glass plate to seal the model. The glass plate was first spin-coated with a thin layer, roughly 10 μm, of PDMS. The micro-model was treated with silane in order to make it uniformly and stably hydrophobic. Fluorescent particles of 300 μm in diameter were used as colloids. It is known that more removal of colloids occurs under unsaturated conditions, compared to saturated flow in soil. At the same time, the change of saturation has been observed to cause remobilization of attached colloids. The mechanisms for these phenomena are not well understood. This is the first time that a closed micro-model, made of PDMS with uniform and stable wettability, has been used in combination with confocal microscopy to study colloid transport under transient two-phase flow conditions. With confocal microscopy, the movement of fluorescent particles and flow of two liquids within the pores can be studied. One can focus at different depths within the pores and thus determine where the particles exactly are. Thus, remobilization of attached colloids by moving fluid-fluid interfaces was visualized. In order to allow for the deposition and subsequent remobilization of colloids during two-phase flow, three micro-channels for the injection of liquids with and without colloids were constructed. An outlet channel was designed where effluent concentration breakthrough curves can be quantified by measuring the fluorescence intensity. A peak concentration also indicated in the breakthrough curve with the drainage event. The acquired images and breakthrough curve successfully confirmed the utility of the combination of such a PDMS

  15. Visualizing Gyrokinetic Turbulence in a Tokamak

    Science.gov (United States)

    Stantchev, George

    2005-10-01

    Multi-dimensional data output from gyrokinetic microturbulence codes are often difficult to visualize, in part due to the non-trivial geometry of the underlying grids, in part due to high irregularity of the relevant scalar field structures in turbulent regions. For instance, traditional isosurface extraction methods are likely to fail for the electrostatic potential field whose level sets may exhibit various geometric pathologies. To address these issues we develop an advanced interactive 3D gyrokinetic turbulence visualization framework which we apply in the study of microtearing instabilities calculated with GS2 in the MAST and NSTX geometries. In these simulations GS2 uses field-line-following coordinates such that the computational domain maps in physical space to a long, twisting flux tube with strong cross-sectional shear. Using statistical wavelet analysis we create a sparse multiple-scale volumetric representation of the relevant scalar fields, which we visualize via a variation of the so called splatting technique. To handle the problem of highly anisotropic flux tube configurations we adapt a geometry-driven surface illumination algorithm that places local light sources for effective feature-enhanced visualization.

  16. Correlation between the critical heat flux and the fractal surface roughness of zirconium alloy tubes

    International Nuclear Information System (INIS)

    Fong, R.W.L.; McRae, G.A.; Coleman, C.E.; Nitheanandan, T.; Sanderson, D.B.

    1999-10-01

    In CANDU fuel channels, Zircaloy calandria tubes isolate the hot pressure tubes from the cool heavy water moderator. The heavy-water moderator provides a backup heat sink during some postulated loss-of-coolant accidents. The decay heat from the fuel is transferred to the moderator to ensure fuel channel integrity during emergencies. Moderator temperature requirements are specified to ensure that the transfer of decay heat does not exceed the critical heat flux (CHF) on the outside surface of the calandria tube. An enhanced CHF provides increases in safety margin. Pool boiling experiments indicate the CHF is enhanced with glass-peening of the outside surface of the calandria tubes. The objective of this study was to evaluate the surface characteristics of glass-peened tubes and relate these characteristics to CHF. The micro-topologies of the tube surfaces were analysed using stereo-pair micrographs obtained from scanning electron microscopy (SEM) and photogrammetry techniques. A linear relationship correlated the CHF as a function of the 'fractal' surface roughness of the tubes. (author)

  17. Preparation, characterization and nonlinear absorption studies of cuprous oxide nanoclusters, micro-cubes and micro-particles

    Science.gov (United States)

    Sekhar, H.; Narayana Rao, D.

    2012-07-01

    Cuprous oxide nanoclusters, micro-cubes and micro-particles were successfully synthesized by reducing copper(II) salt with ascorbic acid in the presence of sodium hydroxide via a co-precipitation method. The X-ray diffraction and FTIR studies revealed that the formation of pure single-phase cubic. Raman and EPR spectral studies show the presence of CuO in as-synthesized powders of Cu2O. Transmission electron microscopy and field emission scanning electron microscopy data revealed that the morphology evolves from nanoclusters to micro-cubes and micro-particles by increasing the concentration of NaOH. Linear optical measurements show absorption peak maximum shifts towards red with changing morphology from nanoclusters to micro-cubes and micro-particles. The nonlinear optical properties were studied using open aperture Z-scan technique with 532 nm 6 ns laser pulses. Samples-exhibited both saturable as well as reverse saturable absorption. Due to confinement effects (enhanced band gap), we observed enhanced nonlinear absorption coefficient (β) in the case of nanoclusters compared to their micro-cubes and micro-particles.

  18. Experimental observations on uniaxial whole-life transformation ratchetting and low-cycle stress fatigue of super-elastic NiTi shape memory alloy micro-tubes

    Science.gov (United States)

    Song, Di; Kang, Guozheng; Kan, Qianhua; Yu, Chao; Zhang, Chuanzeng

    2015-07-01

    In this work, the low-cycle fatigue failure of super-elastic NiTi shape memory alloy micro-tubes with a wall thickness of 150 μm is investigated by uniaxial stress-controlled cyclic tests at human body temperature 310 K. The effects of mean stress, peak stress, and stress amplitude on the uniaxial whole-life transformation ratchetting and fatigue failure of the NiTi alloy are observed. It is concluded that the fatigue life depends significantly on the stress levels, and the extent of martensite transformation and its reverse play an important role in determining the fatigue life. High peak stress or complete martensite transformation shortens the fatigue life.

  19. Experimental observations on uniaxial whole-life transformation ratchetting and low-cycle stress fatigue of super-elastic NiTi shape memory alloy micro-tubes

    International Nuclear Information System (INIS)

    Song, Di; Kang, Guozheng; Kan, Qianhua; Yu, Chao; Zhang, Chuanzeng

    2015-01-01

    In this work, the low-cycle fatigue failure of super-elastic NiTi shape memory alloy micro-tubes with a wall thickness of 150 μm is investigated by uniaxial stress-controlled cyclic tests at human body temperature 310 K. The effects of mean stress, peak stress, and stress amplitude on the uniaxial whole-life transformation ratchetting and fatigue failure of the NiTi alloy are observed. It is concluded that the fatigue life depends significantly on the stress levels, and the extent of martensite transformation and its reverse play an important role in determining the fatigue life. High peak stress or complete martensite transformation shortens the fatigue life. (paper)

  20. The YouTube Makeup Class

    Science.gov (United States)

    Haase, David G.

    2009-05-01

    When a college instructor goes out of town and must miss a lecture, the standard options are to cancel the class meeting or to enlist a colleague to fill in. In the former case a teaching opportunity is lost; in the latter the substitute may not lead the class in the same way as the instructor. Some students routinely skip lectures by a guest instructor, in the belief that the material in the substitute lecture will not be covered on the exam. There are other makeup options such as a directed study assignment. For instance, a missed class is sometimes a good opportunity to require students to investigate web-based simulations such as Physlets® that illustrate the class topics. These are most effective if the students are given a clear structure and if there are questions that the students must answer from their investigations with the Physlets. But many students are more comfortable with the audio and visual communication that occurs in the classroom. Web 2.0 technology, e.g., YouTube (http://www.youtube.com), makes it convenient for faculty to upload videos of lectures and demonstrations that can be used for makeup classes. College students already use YouTube for entertainment, and the YouTube format is simple to view on any web-connected computer. Although some universities have highly developed media delivery systems, YouTube is extremely convenient and accessible by anyone. This paper discusses how a YouTube makeup class can be efficiently produced and structured to be an effective learning experience.

  1. Application of neutron radiography to visualization of multiphase flows

    International Nuclear Information System (INIS)

    Takenaka, N.; Fujii, T.; Nishizaki, K.; Asano, H.; Ono, A.; Sonoda, K.; Akagawa, K.

    1990-01-01

    Visualizations by real-time neutron radiography are demonstrated of various flow patterns of nitrogen gas-water two-phase flow in a stainless-steel tube, water inverted annular flow in a stainless-steel tube, flashing flow in an aluminium nozzle and fluidized bed in aluminium tube and vessels. Photographs every 1/60 s are presented by an image processing method to show the dynamic behaviours of the various flow patterns. It is shown that this visualization method can be applied efficiently to multiphase flow researches and will be applicable to multiphase flows in industrial machines. (author)

  2. Holographic NDE of pressure tubes for Cirene nuclear reactor

    International Nuclear Information System (INIS)

    Di Chirico, G.; Pirodda, L.; Villani, A.

    1985-01-01

    Pressure tubes for CIRENE nuclear reactor can be subjected to fretting corrosion of the inner walls. The resulting marks exhibit different geometries, whose influence on the structural behaviour of the tubes has been evaluated by means of a real time holographic technique. The paper shows the results of this investigation. Position and shape of internal defects have been directly visualized by observing holographic fringe distorsions on the outside surface of the tubes. Furthermore, through the fringe patterns, circumferential stress values have also been obtained. (Author) [pt

  3. A multiscale method for modeling high-aspect-ratio micro/nano flows

    Science.gov (United States)

    Lockerby, Duncan; Borg, Matthew; Reese, Jason

    2012-11-01

    In this paper we present a new multiscale scheme for simulating micro/nano flows of high aspect ratio in the flow direction, e.g. within long ducts, tubes, or channels, of varying section. The scheme consists of applying a simple hydrodynamic description over the entire domain, and allocating micro sub-domains in very small ``slices'' of the channel. Every micro element is a molecular dynamics simulation (or other appropriate model, e.g., a direct simulation Monte Carlo method for micro-channel gas flows) over the local height of the channel/tube. The number of micro elements as well as their streamwise position is chosen to resolve the geometrical features of the macro channel. While there is no direct communication between individual micro elements, coupling occurs via an iterative imposition of mass and momentum-flux conservation on the macro scale. The greater the streamwise scale of the geometry, the more significant is the computational speed-up when compared to a full MD simulation. We test our new multiscale method on the case of a converging/diverging nanochannel conveying a simple Lennard-Jones liquid. We validate the results from our simulations by comparing them to a full MD simulation of the same test case. Supported by EPSRC Programme Grant, EP/I011927/1.

  4. Investigations of the Failure in Boilers Economizer Tubes Used in Power Plants

    Science.gov (United States)

    Moakhar, Roozbeh Siavash; Mehdipour, Mehrad; Ghorbani, Mohammad; Mohebali, Milad; Koohbor, Behrad

    2013-09-01

    In this study, failure of a high pressure economizer tube of a boiler used in gas-Mazut combined cycle power plants was studied. Failure analysis of the tube was accomplished by taking into account visual inspection, thickness measurement, and hardness testing as well as microstructural observations using scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS), and x-ray diffraction (XRD). Optical microscopy images indicate that there is no phase transformation during service, and ferrite-pearlite remained. The results of XRD also revealed Iron sulfate (FeSO4) and Iron hydroxide sulfate (FeOH(SO4)) phases formed on the steel surface. A considerable amount of Sulfur was also detected on the outer surface of the tube by EDS analysis. Dew-point corrosion was found to be the principal reason for the failure of the examined tube while it has been left out-of-service.

  5. Characteristics of a micro-fin evaporator: Theoretical analysis and experimental verification

    OpenAIRE

    Zheng Hui-Fan; Fan Xiao-Wei; Wang Fang; Liang Yao-Hua

    2013-01-01

    A theoretical analysis and experimental verification on the characteristics of a micro-fin evaporator using R290 and R717 as refrigerants were carried out. The heat capacity and heat transfer coefficient of the micro-fin evaporator were investigated under different water mass flow rate, different refrigerant mass flow rate, and different inner tube diameter of micro-fin evaporator. The simulation results of the heat transfer coefficient are fairly in good a...

  6. Development of micro pattern cutting simulation software

    International Nuclear Information System (INIS)

    Lee, Jong Min; Song, Seok Gyun; Choi, Jeong Ju; Novandy, Bondhan; Kim, Su Jin; Lee, Dong Yoon; Nam, Sung Ho; Je, Tae Jin

    2008-01-01

    The micro pattern machining on the surface of wide mold is not easy to be simulated by conventional software. In this paper, a software is developed for micro pattern cutting simulation. The 3d geometry of v-groove, rectangular groove, pyramid and pillar patterns are visualized by c++ and OpenGL library. The micro cutting force is also simulated for each pattern

  7. Slip of the T tube within the common bile duct: A little known complication of the T tube drainage

    Directory of Open Access Journals (Sweden)

    Čolović Radoje

    2005-01-01

    Full Text Available Complications related to the T tube drainage of the common bile duct are not uncommon. Some, like dislocations of the T tube out of the common bile duct, could be very serious, particularly if developed during the first few days after surgery, when the abdominal drain in the subhepatic space had been already removed. Then, an emergency reoperation might be necessary. The slip of the T tube upwards or downwards inside the common bile duct is not so rare. Fortunately, it is less dangerous and can usually be resolved without reoperation. It takes place several days after surgery, followed by the right subcostal pain, occasionally with temperature, rise of the bilirubin and with decrease or complete cessation of the bile drainage through the T tube. The diagnosis can be made only on the basis of T tube cholangiography. The re-establishment of the proper T tube position must be done under X-ray visualization. Seven cases of the T tube slip within the common bile duct, its clinical presentation, diagnosis and method of repositioning were presented. Possible mechanism of complication was described. As far as we know, the complications have not been described by other authors.

  8. A Study on the Profile Change Measurement of Steam Generator Tubes with Tube Expansion Methods

    International Nuclear Information System (INIS)

    Kim, Young Kyu; Song Myung Ho; Choi, Myung Sik

    2011-01-01

    Steam generator tubes for nuclear power plants contain the local shape transitions on their inner or outer surface such as dent, bulge, over-expansion, eccentricity, deflection, and so on by the application of physical force during the tube manufacturing and steam generator assembling and by the sludge (that is, corrosion products) produced during the plant operation. The structural integrity of tubes will be degraded by generating the corrosive crack at that location. The profilometry using the traditional bobbin probes which are currently applied for measuring the profile change of tubes gives us basic information such as axial locations and average magnitudes of deformations. However, the three-dimensional quantitative evaluation on circumferential locations, distributional angle, and size of deformations will have to be conducted to understand the effects of residual stresses increased by local deformations on corrosive cracking of tubes. Steam generator tubes of Korean standard nuclear power plants expanded within their tube-sheets by the explosive expansion method and suffered from corrosive cracks in the early stage of power operation. Thus, local deformations of steam generator tubes at the top of tube-sheet were measured with an advanced rotating probe and a laser profiling system for the two cases where the tubes expanded by the explosive expansion method and hydraulic expansion. Also, the trends of eccentricity, deflection, and over-expansion of tubes were evaluated. The advanced eddy current profilometry was confirmed to provide accurate information of local deformations compared with laser profilometry

  9. Imaging study of pancreatic ductal adenocarcinomas in Syrian hamsters using X-ray micro-computed tomography (CT)

    International Nuclear Information System (INIS)

    Kitahashi, Tsukasa; Mutoh, Michihiro; Tsurusaki, Masakatsu

    2010-01-01

    X-ray computed tomography (CT) has been used for diagnoses of human pancreatic cancer. Although micro-CT is a useful approach to evaluate macromorphology of organs/tissue also in animal models, reports on pancreatic tumors are limited. In this study, the utility of micro-CT was assessed in characterizing chemically induced pancreatic tumors in Syrian hamsters. Hamsters treated with or without N-nitrosobis(2-oxopropyl)amine (BOP) were injected with the antispasmodic agent, scopolamine butylbromide, and contrast agents, 5 or 10 mL/kg body weight of iopamidol or Fenestra VC at 18-38 weeks, then examined by micro-CT scanning with a respiratory gating system. Both peristaltic and respiratory movements were substantially suppressed by the combination of scopolamine butylbromide treatment and the respiratory gating system, resulting in improvements of image qualities. Iopamidol clearly visualized the pancreatic parenchyma and contrasted the margins among the pancreas and other abdominal organs/tissue. Meanwhile Fenestra VC predominantly contrasted abdominal vascular systems, but the margins among pancreas and other organs/tissue remained obscure. Six pancreatic tumors of 4-13 mm in diameter were detected in four of 15 animals, but not the five tumors of 1-4 mm in diameter. The inner tumor images were heterogeneously or uniformly visualized by iopamidol and Fenestra VC. Overall, iopamidol could clearly contrast between pancreatic parenchyma and the tumors as compared with Fenestra VC. All tumors confirmed were histopathologically diagnosed as pancreatic ductal adenocarcinomas. Thus, micro-CT could be useful to evaluate the carcinogenic processes and preventive methods of pancreatic cancer in hamsters and to assess the novel contrast agents for detection of small pancreatic cancer in humans. (author)

  10. Micro/nano-computed tomography technology for quantitative dynamic, multi-scale imaging of morphogenesis.

    Science.gov (United States)

    Gregg, Chelsea L; Recknagel, Andrew K; Butcher, Jonathan T

    2015-01-01

    Tissue morphogenesis and embryonic development are dynamic events challenging to quantify, especially considering the intricate events that happen simultaneously in different locations and time. Micro- and more recently nano-computed tomography (micro/nanoCT) has been used for the past 15 years to characterize large 3D fields of tortuous geometries at high spatial resolution. We and others have advanced micro/nanoCT imaging strategies for quantifying tissue- and organ-level fate changes throughout morphogenesis. Exogenous soft tissue contrast media enables visualization of vascular lumens and tissues via extravasation. Furthermore, the emergence of antigen-specific tissue contrast enables direct quantitative visualization of protein and mRNA expression. Micro-CT X-ray doses appear to be non-embryotoxic, enabling longitudinal imaging studies in live embryos. In this chapter we present established soft tissue contrast protocols for obtaining high-quality micro/nanoCT images and the image processing techniques useful for quantifying anatomical and physiological information from the data sets.

  11. Development of confocal micro X-ray fluorescence instrument using two X-ray beams

    International Nuclear Information System (INIS)

    Tsuji, Kouichi; Nakano, Kazuhiko; Ding Xunliang

    2007-01-01

    A new confocal micro X-ray fluorescence instrument was developed. This instrument has two independent micro X-ray tubes with Mo targets. A full polycapillary X-ray lens was attached to each X-ray tube. Another half polycapillary lens was attached to a silicon drift X-ray detector (SDD). The focal spots of the three lenses were adjusted to a common position. The effects of the excitation of two X-ray beams were investigated. The instrument enabled highly sensitive three-dimensional X-ray fluorescence analysis. We confirmed that the X-ray fluorescence intensity from the sample increased by applying the two independent X-ray tubes in confocal configuration. Elemental depth profiling of black wheat was demonstrated with the result that each element in the surface coat of a wheat grain showed unique distribution

  12. Spectral Optical Readout of Rectangular-Miniature Hollow Glass Tubing for Refractive Index Sensing.

    Science.gov (United States)

    Rigamonti, Giulia; Bello, Valentina; Merlo, Sabina

    2018-02-16

    For answering the growing demand of innovative micro-fluidic devices able to measure the refractive index of samples in extremely low volumes, this paper presents an overview of the performances of a micro-opto-fluidic sensing platform that employs rectangular, miniature hollow glass tubings. The operating principle is described by showing the analytical model of the tubing, obtained as superposition of different optical cavities, and the optical readout method based on spectral reflectivity detection. We have analyzed, in particular, the theoretical and experimental optical features of rectangular tubings with asymmetrical geometry, thus with channel depth larger than the thickness of the glass walls, though all of them in the range of a few tens of micrometers. The origins of the complex line-shape of the spectral response in reflection, due to the different cavities formed by the tubing flat walls and channel, have been investigated using a Fourier transform analysis. The implemented instrumental configuration, based on standard telecom fiberoptic components and a semiconductor broadband optical source emitting in the near infrared wavelength region centered at 1.55 µm, has allowed acquisition of reflectivity spectra for experimental verification of the expected theoretical behavior. We have achieved detection of refractive index variations related to the change of concentration of glucose-water solutions flowing through the tubing by monitoring the spectral shift of the optical resonances.

  13. Spectral Optical Readout of Rectangular–Miniature Hollow Glass Tubing for Refractive Index Sensing

    Science.gov (United States)

    Rigamonti, Giulia; Bello, Valentina

    2018-01-01

    For answering the growing demand of innovative micro-fluidic devices able to measure the refractive index of samples in extremely low volumes, this paper presents an overview of the performances of a micro-opto-fluidic sensing platform that employs rectangular, miniature hollow glass tubings. The operating principle is described by showing the analytical model of the tubing, obtained as superposition of different optical cavities, and the optical readout method based on spectral reflectivity detection. We have analyzed, in particular, the theoretical and experimental optical features of rectangular tubings with asymmetrical geometry, thus with channel depth larger than the thickness of the glass walls, though all of them in the range of a few tens of micrometers. The origins of the complex line-shape of the spectral response in reflection, due to the different cavities formed by the tubing flat walls and channel, have been investigated using a Fourier transform analysis. The implemented instrumental configuration, based on standard telecom fiberoptic components and a semiconductor broadband optical source emitting in the near infrared wavelength region centered at 1.55 µm, has allowed acquisition of reflectivity spectra for experimental verification of the expected theoretical behavior. We have achieved detection of refractive index variations related to the change of concentration of glucose-water solutions flowing through the tubing by monitoring the spectral shift of the optical resonances. PMID:29462907

  14. CT colonography for preoperative examination of the proximal colon using a transanal drainage tube for acute malignant colonic obstruction

    International Nuclear Information System (INIS)

    Sasaki, Kazuaki; Hirano, Yuji; Oono, Keisuke; Sasaki, Kazunori; Someya, Tetsufumi; Harada, Keisuke; Ezoe, Eiri; Furuhata, Tomohisa; Hirata, Koichi

    2011-01-01

    The purpose of this study was to evaluate the feasibility of CT colonography for preoperative examination of the proximal colon using a transanal drainage tube in patients with acute colon obstruction caused by colorectal cancer. Ten patients who received initial treatment for acute malignant colon obstruction at our hospital between June 2004 and December 2008 were studied. In these patients, elective surgery was possible after transanal drainage tube insertion, and the colon on the oral side from the cancer lesion was examined using a drainage tube. Air was injected through the tube into the oral side of the colon, and CT colonography was assessed for the presence or absence of lesions on the oral side. The images of the oral side of the colon were good enough to allow adequate interpretation in 9 of the 10 patients. In the first patient, the visualization of the area near the lesion was somewhat fair, although the right side colon was well visualized. There were no complications associated with this examination. The present preoperative examination using a transanal drainage tube was useful for determining the extent of intestinal resection when patients were not candidates for colonoscopy or barium enema examination. (author)

  15. A Study on the Small Punch Test for Fracture Strength Evaluation of CANDU Pressure Tube Embrittled by Hydrogen

    International Nuclear Information System (INIS)

    Nho, Seung Hwan; Ong, Jang Woo; Yu, Hyo Sun; Chung, Se Hi

    1996-01-01

    The purpose of this study is to investigate the usefulness of small punch(SP) test using miniaturized specimens as a method for fracture strength evaluation of CANDU pressure tube embrittled by hydrogen. According to the test results, the fracture strength evaluation as a function of hydrogen concentration at -196 .deg. C was much better than that at room temperature, as the difference of SP fracture energy(Esp) with hydrogen concentration was more significant at -196 .deg. C than at room temperature for the hydrogen concentration up to 300ppm-H. It was also observed that the peak of average AE energy, the cumulative average AE energy and the cumulative average AE energy per equivalent fracture, strain increased with the increase of hydrogen concentration. From the results of load-displacement behaviors, Esp behaviors, macro- and micro-SEM fractographs and AE test it has been concluded that the SP test method using miniaturized specimen(10mmx10mmx0.5mm) will be a useful test method to evaluate the fracture strength for CANDU pressure tube embrittled by hydrogen

  16. T(2)-weighted microMRI and evoked potential of the visual system measurements during the development of hypomyelinated transgenic mice.

    Science.gov (United States)

    Martin, Melanie; Reyes, Samuel D; Hiltner, Timothy D; Givogri, M Irene; Tyszka, J Michael; Fisher, Robin; Campagnoni, Anthony T; Fraser, Scott E; Jacobs, Russell E; Readhead, Carol

    2007-02-01

    Our objective was to follow the course of a dysmyelinating disease followed by partial recovery in transgenic mice using non-invasive high-resolution (117 x 117 x 70 microm) magnetic resonance (microMRI) and evoked potential of the visual system (VEP) techniques. We used JOE (for J37 golli overexpressing) transgenic mice engineered to overexpress golli J37, a product of the Golli-mbp gene complex, specifically in oligodendrocytes. Individual JOE transgenics and their unaffected siblings were followed from 21 until 75-days-old using non-invasive in vivo VEPs and 3D T2-weighted microMRI on an 11.7 T scanner, performing what we believe is the first longitudinal study of its kind. The microMRI data indicated clear, global hypomyelination during the period of peak myelination (21-42 days), which was partially corrected at later ages (>60 days) in the JOE mice compared to controls. These microMRI data correlated well with [Campagnoni AT (1995) "Molecular biology of myelination". In: Ransom B, Kettenmann H (eds) Neuroglia--a Treatise. Oxford University Press, London, pp 555-570] myelin staining, [Campagnoni AT, Macklin WB (1988) Cellular and molecular aspects of myelin protein gene-expression. Mol Neurobiol 2:41-89] a transient intention tremor during the peak period of myelination, which abated at later ages, and [Lees MB, Brostoff SW (1984) Proteins in myelin. In: Morell (ed) Myelin. Plenum Press, New York and London, pp 197-224] VEPs which all indicated a significant delay of CNS myelin development and persistent hypomyelination in JOE mice. Overall these non-invasive techniques are capable of spatially resolving the increase in myelination in the normally developing and developmentally delayed mouse brain.

  17. Inspection and repair of steam generator tubing with a robot

    International Nuclear Information System (INIS)

    Boehm, H.H.; Foerch, H.

    1985-01-01

    During inspection and repair of steam generator tubing, radiation exposure to personnel is an unrequested endowment. To combat this intrinsic handicap, a robot has been designed for deployment in all operations inside the steam generator water chamber. This measure drastically reduces entering time and also improves inspection capabilities with regard to the accuracy and reproduction of the desired tube address. The inherent flexibility of the robot allows for performing various inspection and repair techniques: eddy-current testing of tubing; ultrasonic testing of tubing; visual examination of tube ends; profilometry measurements; tube plugging; plug removal; tube extraction; sleeving of tubes; tube end repair; chemical cleaning; and thermal treatment. Plant experience has highlighted the following features of the robot: 1) short installation and demounting periods; 2) installation independent of manhole location; 3) installation possible from outside the steam generator; 4) only one relocation required to address all the tube positions; 5) fast and highly accurate positioning; 6) operational surveillance not required; and 7) drastic reduction of radiation exposure to personnel during repair work

  18. Wear of micro end mills

    DEFF Research Database (Denmark)

    Bissacco, Giuliano; Hansen, Hans Nørgaard; De Chiffre, Leonardo

    2005-01-01

    This paper addresses the important issue of wear on micro end mills considering relevant metrological tools for its characterization and quantification. Investigation of wear on micro end mills is particularly difficult and no data are available in the literature. Small worn volumes cause large...... part. For this investigation 200 microns end mills are considered. Visual inspection of the micro tools requires high magnification and depth of focus. 3D reconstruction based on scanning electron microscope (SEM) images and stereo-pair technique is foreseen as a possible method for quantification...

  19. Failure Investigation of Radiant Platen Superheater Tube of Thermal Power Plant Boiler

    Science.gov (United States)

    Ghosh, D.; Ray, S.; Mandal, A.; Roy, H.

    2015-04-01

    This paper highlights a case study of typical premature failure of a radiant platen superheater tube of 210 MW thermal power plant boiler. Visual examination, dimensional measurement and chemical analysis, are conducted as part of the investigations. Apart from these, metallographic analysis and fractography are also conducted to ascertain the probable cause of failure. Finally it has been concluded that the premature failure of the super heater tube can be attributed to localized creep at high temperature. The corrective actions has also been suggested to avoid this type of failure in near future.

  20. A Study on Thermal Performance of a Novel All-Glass Evacuated Tube Solar Collector Manifold Header with an Inserted Tube

    Directory of Open Access Journals (Sweden)

    Jichun Yang

    2015-01-01

    Full Text Available A novel all-glass evacuated tube collector manifold header with an inserted tube is proposed in this paper which makes water in all-glass evacuated solar collector tube be forced circulated to improve the performance of solar collector. And a dynamic numerical model was presented for the novel all-glass evacuated tube collector manifold header water heater system. Also, a test rig was built for model validation and comparison with traditional all-glass evacuated tube collector. The experiment results show that the efficiency of solar water heater with a novel collector manifold header is higher than traditional all-glass evacuated tube collector by about 5% and the heat transfer model of water heater system is valid. Based on the model, the relationship between the average temperature of water tank and inserted tube diameter (water mass flow has been studied. The results show that the optimized diameter of inserted tube is 32 mm for the inner glass with the diameter of 47 mm and the water flow mass should be less than 1.6 Kg/s.

  1. m-YouTube Mobile UI: Video Selection Based on Social Influence

    Science.gov (United States)

    Marcus, Aaron; Perez, Angel

    The ease-of-use of Web-based video-publishing services provided by applications like YouTube has encouraged a new means of asynchronous communication, in which users can post videos not only to make them public for review and criticism, but also as a way to express moods, feelings, or intentions to an ever-growing network of friends. Following the current trend of porting Web applications onto mobile platforms, the authors sought to explore user-interface design issues of a mobile-device-based YouTube, which they call m-YouTube. They first analyzed the elements of success of the current YouTube Web site and observed its functionality. Then, they looked for unsolved issues that could give benefit through information-visualization design for small screens on mobile phones to explore a mobile version of such a product/service. The biggest challenge was to reduce the number of functions and amount information to fit into a mobile phone screen, but still be usable, useful, and appealing within the YouTube context of use and user experience. Borrowing ideas from social research in the area of social influence processes, they made design decisions aiming to help YouTube users to make the decision of what video content to watch and to increase the chances of YouTube authors being evaluated and observed by peers. The paper proposes a means to visualize large amounts of video relevant to YouTube users by using their friendship network as a relevance indicator to help in the decision-making process.

  2. How social media meet patients’ questions: YouTube™ review for children oral thrush.

    Science.gov (United States)

    Di Stasio, D; Romano, A N; Paparella, R S; Gentile, C; Minervini, G; Serpico, R; Candotto, V; Laino, L

    2018-01-01

    YouTube™ is increasingly being used by patients to obtain health-related information. No studies have evaluated the content of YouTube™ videos on children oral thrush. The aim of this work is to examine the quality of information offered by this platform about oral thrush in children. Searching term “oral thrush in children” (OTC) displayed a total of 2.790 results. Of the top 60 videos analyzed, 27 were excluded. The main source of upload was from generalist information YouTube® channels (GC) followed by healthcare professionals (HP), individual users (IU), and healthcare information channels (HC); usefulness of videos is successfully correlated with the number of visualization, number of likes and viewing rate and was interdependent with the number of visualizations, number of likes and VR. However, videos on the oral thrush do not have satisfactory quality information. HP themselves, along with HC, do not seem to provide more appropriate information on COT, than GC or IU.

  3. Visual inspection equipment for the secondary side of steam generators. Final report

    International Nuclear Information System (INIS)

    Hinton, M.S.; Chagnon, C.W.

    1981-05-01

    The development of miniature visual examination equipment capable of inspecting regions inside the tube bundles of nuclear steam generators to determine such factors as gap condition, tube outside surface condition, and material buildup is described. Tube-to-support plate interface regions at the tenth-support plate level in a once-through steam generator (Oconee 1) were visually examined. Other areas in the peripheral region were examined for conditions associated with available eddy-current and profilometer data

  4. An Empirical Study on Using Visual Embellishments in Visualization.

    Science.gov (United States)

    Borgo, R; Abdul-Rahman, A; Mohamed, F; Grant, P W; Reppa, I; Floridi, L; Chen, Min

    2012-12-01

    In written and spoken communications, figures of speech (e.g., metaphors and synecdoche) are often used as an aid to help convey abstract or less tangible concepts. However, the benefits of using rhetorical illustrations or embellishments in visualization have so far been inconclusive. In this work, we report an empirical study to evaluate hypotheses that visual embellishments may aid memorization, visual search and concept comprehension. One major departure from related experiments in the literature is that we make use of a dual-task methodology in our experiment. This design offers an abstraction of typical situations where viewers do not have their full attention focused on visualization (e.g., in meetings and lectures). The secondary task introduces "divided attention", and makes the effects of visual embellishments more observable. In addition, it also serves as additional masking in memory-based trials. The results of this study show that visual embellishments can help participants better remember the information depicted in visualization. On the other hand, visual embellishments can have a negative impact on the speed of visual search. The results show a complex pattern as to the benefits of visual embellishments in helping participants grasp key concepts from visualization.

  5. MicroRNA from tuberculosis RNA: A bioinformatics study

    OpenAIRE

    Wiwanitkit, Somsri; Wiwanitkit, Viroj

    2012-01-01

    The role of microRNA in the pathogenesis of pulmonary tuberculosis is the interesting topic in chest medicine at present. Recently, it was proposed that the microRNA can be a useful biomarker for monitoring of pulmonary tuberculosis and might be the important part in pathogenesis of disease. Here, the authors perform a bioinformatics study to assess the microRNA within known tuberculosis RNA. The microRNA part can be detected and this can be important key information in further study of the p...

  6. Isometric force exaggeration in simulated weightlessness by water immersion: role of visual feedback.

    Science.gov (United States)

    Dalecki, Marc; Bock, Otmar

    2014-06-01

    Previous studies reported that humans produce exaggerated isometric forces (20-50%) in microgravity, hypergravity, and under water. Subjects were not provided with visual feedback and exaggerations were attributed to proprioceptive deficits. The few studies that provided visual feedback in micro- and hypergravity found no deficits. The present work was undertaken to find out whether visual feedback can reduce or eliminate isometric force exaggerations during shallow water immersion, a working environment for astronauts and divers. There were 48 subjects who had to produce isometric forces of 15 N with a joystick; targets were presented via screen. Procedures were similar to earlier studies, but provided visual feedback. Subjects were tested 16.4 ft (5 m) under water (WET) and on dry land (DRY). Response accuracy was calculated with landmarks such as initial and peak force magnitude, and response timing. Initial force and response timing were equal in WET compared to DRY. A small but significant force exaggeration (+5%) remained for peak force in WET that was limited to directions toward the trunk. Force exaggeration under water is largely compensated, but not completely eliminated by visual feedback. As in earlier studies without visual feedback, force exaggeration manifested during later but not early response parts, speaking for impaired proprioceptive feedback rather than for erroneous central motor planning. Since in contrast to micro/hypergravity, visual feedback did not sufficiently abolish force deficits under water, proprioceptive information seems to be weighted differently in micro/hypergravity and shallow water immersion, probably because only the latter environment produces increased ambient pressure, which is known to induce neuronal changes.

  7. Thermal performance comparison of oscillating heat pipes with and without helical micro-grooves

    Science.gov (United States)

    Qu, Jian; Li, Xiaojun; Xu, Qian; Wang, Qian

    2017-11-01

    This paper presents an experimental investigation to compare the thermal performance of three closed loop oscillating heat pipes (OHPs) with and without internal helical microgrooves at vertical and horizontal orientations. All of these OHPs were made from copper tubes and have three turns with lengths of 70, 230 and 110 mm at the evaporator, adiabatic and condenser sections, respectively. Deionized water was used as the working fluid at a volumetric filling ratio of 50%. The internal diameters (IDs) of two smooth-tube OHPs are 4.0 and 4.8 mm, respectively, and the internal diameter of micro-grooved OHP without groove structures is about 4.5 mm. Experimental results demonstrated that the addition of groove structures make the OHP remarkably outperform smooth-tube OHPs in both effective thermal conductivity and thermal resistance. The thermal resistance of vertically-oriented micro-grooved OHP could be lowered to 0.057 °C/W associated with an effective thermal conductivity of 6.1 × 104 W/ (m·K) at the input heat flux of 3.8 × 104 W/m2. Compared to smooth-tube OHPs, preliminary mechanism analysis reveals that local heat transfer coefficients both at the heating and cooling sections of micro-grooved OHP could be significantly improved. Moreover, enhanced liquid backflow to the evaporator due to microgroove-induced capillarity is also responsible for the OHP performance enhancement.

  8. Bioactive surface modifications on inner walls of poly-tetra-fluoro-ethylene tubes using dielectric barrier discharge

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Yong Ki [Department of Physics, Sungkyunkwan University, Suwon 440-746 (Korea, Republic of); Heat Treatment and Surface Engineering R and D Group, Korea Institute of Industrial Technology, Incheon 406-840 (Korea, Republic of); Park, Daewon; Kim, Hoonbae [Department of Physics, Sungkyunkwan University, Suwon 440-746 (Korea, Republic of); Lee, Hyerim; Park, Heonyong [Department of Molecular Biology, Dankook University, Yongin 448-701 (Korea, Republic of); Kim, Hong Ja [Department of Internal Medicine, Dankook University, Cheonan 330-714 (Korea, Republic of); Jung, Donggeun, E-mail: djung@skku.ac.kr [Department of Physics, Sungkyunkwan University, Suwon 440-746 (Korea, Republic of)

    2014-03-01

    Graphical abstract: - Highlights: • The surface modification of the inner walls of poly-tetra-fluoro-ethylene (PTFE) tubing was carried out to improve vascular grafts. • Focus was centered on the cell attachment of the inner wall of the PTFE by sequential processes of hydrogen plasma treatment, hydrocarbon deposition, and reactive plasma treatment using micro plasma discharge. - Abstract: Bioactive surface modification can be used in a variety of medical polymeric materials in the fields of biochips and biosensors, artificial membranes, and vascular grafts. In this study, the surface modification of the inner walls of poly-tetra-fluoro-ethylene (PTFE) tubing was carried out to improve vascular grafts, which are made of biocompatible material for the human body in the medical field. Focus was centered on the cell attachment of the inner wall of the PTFE by sequential processes of hydrogen plasma treatment, hydrocarbon deposition, and reactive plasma treatment on the PFTE surface using micro plasma discharge. Micro plasma was generated by a medium-frequency alternating current high-voltage generator. The preliminary modification of PTFE was conducted by a plasma of hydrogen and argon gases. The hydrocarbon thin film was deposited on modified PTFE with a mixture of acetylene and argon gases. The reactive plasma treatment using oxygen plasma was done to give biocompatible functionality to the inner wall surface. The hydrophobic surface of bare PTFE is made hydrophilic by the reactive plasma treatment due to the formation of carbonyl groups on the surface. The reactive treatment could lead to improved attachment of smooth muscle cells (SMCs) on the modified PTFE tubing. Fourier transform infrared absorption spectroscopy, X-ray photoelectron spectroscopy, scanning electron microscopy, and water contact angle measurement were used for the analysis of the surface modification. The SMC-attached PTFE tube developed will be applicable to in vitro human vasculature

  9. Bioactive surface modifications on inner walls of poly-tetra-fluoro-ethylene tubes using dielectric barrier discharge

    International Nuclear Information System (INIS)

    Cho, Yong Ki; Park, Daewon; Kim, Hoonbae; Lee, Hyerim; Park, Heonyong; Kim, Hong Ja; Jung, Donggeun

    2014-01-01

    Graphical abstract: - Highlights: • The surface modification of the inner walls of poly-tetra-fluoro-ethylene (PTFE) tubing was carried out to improve vascular grafts. • Focus was centered on the cell attachment of the inner wall of the PTFE by sequential processes of hydrogen plasma treatment, hydrocarbon deposition, and reactive plasma treatment using micro plasma discharge. - Abstract: Bioactive surface modification can be used in a variety of medical polymeric materials in the fields of biochips and biosensors, artificial membranes, and vascular grafts. In this study, the surface modification of the inner walls of poly-tetra-fluoro-ethylene (PTFE) tubing was carried out to improve vascular grafts, which are made of biocompatible material for the human body in the medical field. Focus was centered on the cell attachment of the inner wall of the PTFE by sequential processes of hydrogen plasma treatment, hydrocarbon deposition, and reactive plasma treatment on the PFTE surface using micro plasma discharge. Micro plasma was generated by a medium-frequency alternating current high-voltage generator. The preliminary modification of PTFE was conducted by a plasma of hydrogen and argon gases. The hydrocarbon thin film was deposited on modified PTFE with a mixture of acetylene and argon gases. The reactive plasma treatment using oxygen plasma was done to give biocompatible functionality to the inner wall surface. The hydrophobic surface of bare PTFE is made hydrophilic by the reactive plasma treatment due to the formation of carbonyl groups on the surface. The reactive treatment could lead to improved attachment of smooth muscle cells (SMCs) on the modified PTFE tubing. Fourier transform infrared absorption spectroscopy, X-ray photoelectron spectroscopy, scanning electron microscopy, and water contact angle measurement were used for the analysis of the surface modification. The SMC-attached PTFE tube developed will be applicable to in vitro human vasculature

  10. Nasogastric tube versus gastrostomy tube for gastric decompression in abdominal surgery: a prospective, randomized trial comparing patients' tube-related inconvenience.

    Science.gov (United States)

    Hoffmann, S; Koller, M; Plaul, U; Stinner, B; Gerdes, B; Lorenz, W; Rothmund, M

    2001-11-01

    Perioperative decompression of the stomach is still a common procedure and can be achieved using either nasogastric tubes (NTs) or gastrostomy tubes (GTs). While both procedures appear to be equally effective, some authors believe that NTs are less convenient for patients than GTs. However, to date, no reliable prospective data are available on this issue. We conducted a prospective, randomized trial comparing NTs versus GTs with a total of 110 patients undergoing elective colon surgery. The primary outcome measure was the patient's tube-related inconvenience and pain, assessed in a standardized interview on day 2 after surgery and quantified by means of a visual-analog scale (VAS). A questionnaire including the EORTC QLQ-C30 and additional items regarding retrospective tube-related judgements was administered on the day of discharge and 4 weeks after discharge. Secondary endpoints were the therapy-related morbidity and general complications. When patients were asked which of their drainage tubes (all patients had three or four drainage tubes, such as decompression drains, urinary drains, central venous line) was most inconvenient, 43% (CI 33-53%) in the NT group reported that the NT was most inconvenient, while only 4% (CI 1-10%) of the GT patients judged the GT most inconvenient ( Ptube system (day 2 p.o.: 71%, CI 61-80%; 4 weeks p.o.: 66%, CI 56-75%) than did GT patients (day 2 p.o.: 94%, CI 88-98%; 4 weeks p.o.: 91% CI 84-96%); again, these differences were statistically significant ( Ptube system have to weigh up the possibilities of different averse clinical as well as subjective outcomes. It is then preferable to include patients' preferences in the individual decision making process (shared-decision making).

  11. Intraluminal erosion of laparoscopic gastric band tubing into duodenum with recurrent port-site infections.

    Science.gov (United States)

    Cintolo, Jessica A; Levine, Marc S; Huang, Stephanie; Dumon, Kristoffel

    2012-01-01

    Intraluminal erosion of a laparoscopic gastric band into the stomach has been reported as a complication of laparoscopic adjustable gastric banding. To our knowledge, however, intraluminal erosion of the band tubing into the duodenum has not been described. We report a 46-year-old man in whom a laparoscopic adjustable gastric band tubing eroded into the duodenal lumen, causing recurrent port-site infections. This complication was diagnosed on upper endoscopy and also, in retrospect, on an upper gastrointestinal barium study and computed tomography. The patient underwent surgical removal of the band and tubing, with a primary duodenal repair, and made a complete recovery without complications. Erosion of laparoscopic band tubing into the duodenum should be included in the differential diagnosis for recurrent port-site infections after laparoscopic adjustable gastric banding. Radiographic or endoscopic visualization of the intraluminal portion of the tubing may be required for confirmation. Definitive treatment of this complication entails surgical removal of the tubing from the duodenum.

  12. Failure Analysis and Magnetic Evaluation of Tertiary Superheater Tube Used in Gas-Fired Boiler

    Science.gov (United States)

    Mohapatra, J. N.; Patil, Sujay; Sah, Rameshwar; Krishna, P. C.; Eswarappa, B.

    2018-02-01

    Failure analysis was carried out on a prematurely failed tertiary superheater tube used in gas-fired boiler. The analysis includes a comparative study of visual examination, chemical composition, hardness and microstructure at failed region, adjacent and far to failure as well as on fresh tube. The chemistry was found matching to the standard specification, whereas the hardness was low in failed tube compared to the fish mouth opening region and the fresh tube. Microscopic examination of failed sample revealed the presence of spheroidal carbides of Cr and Mo predominantly along the grain boundaries. The primary cause of failure is found to be localized heating. Magnetic hysteresis loop (MHL) measurements were carried out to correlate the magnetic parameters with microstructure and mechanical properties to establish a possible non-destructive evaluation (NDE) for health monitoring of the tubes. The coercivity of the MHL showed a very good correlation with microstructure and mechanical properties deterioration enabling a possible NDE technique for the health monitoring of the tubes.

  13. Characteristics of a micro-fin evaporator: Theoretical analysis and experimental verification

    Directory of Open Access Journals (Sweden)

    Zheng Hui-Fan

    2013-01-01

    Full Text Available A theoretical analysis and experimental verification on the characteristics of a micro-fin evaporator using R290 and R717 as refrigerants were carried out. The heat capacity and heat transfer coefficient of the micro-fin evaporator were investigated under different water mass flow rate, different refrigerant mass flow rate, and different inner tube diameter of micro-fin evaporator. The simulation results of the heat transfer coefficient are fairly in good agreement with the experimental data. The results show that heat capacity and the heat transfer coefficient of the micro-fin evaporator increase with increasing logarithmic mean temperature difference, the water mass flow rate and the refrigerant mass flow rate. Heat capacity of the micro-fin evaporator for diameter 9.52 mm is higher than that of diameter 7.00 mm with using R290 as refrigerant. Heat capacity of the micro-fin evaporator with using R717 as refrigerant is higher than that of R290 as refrigerant. The results of this study can provide useful guidelines for optimal design and operation of micro-fin evaporator in its present or future applications.

  14. Archiving the Wonders of Testosterone via YouTube

    DEFF Research Database (Denmark)

    Raun, Tobias

    2015-01-01

    The article engages with trans male video blogs on YouTube, framing them as living archives that offer unique opportunities to access and share embodied trans knowledges—which have previously been limited or inaccessible—such as information about and visual accounts of medical transitioning...... the privileged site of self-fashioning. YouTube hereby offers an alternative and empowering archive of how trans male bodies could look, while its cumulative effects also play a significant role in determining how they should look....

  15. A Study on the Development of Nonglass Solar Vacuum Tube Collector

    International Nuclear Information System (INIS)

    Oh, Seung Jin

    2008-02-01

    Nature has been providing us energy from the beginning of the world. However human has hardly used it wisely. Solar energy is a kind of renewable energy from the nature. This study has been carried out to study the use of solar energy as it is harnessed in the form of thermal energy. Solar energy is one of the most promising energy resources such as hydrogen, biomass, wind and geothermal energy, because it is clean and inexhaustible. Space heating in buildings can be provided from solar energy by systems that are similar in many respects to water heater systems. By tapping into solar energy, we can not only solve the problem of energy shortage, but also can protect the environment and benefit the human beings. There are currently two types of evacuated tube; a single glass tube and a double glass tube. The former consists of a single glass tube which contains a flat or curved aluminium plate attached to a copper heat pipe or water flow pipe. The latter consists of rows of parallel transparent glass tubes, each of which contains an absorber tube. Evacuated tube collectors introduced above, however, pose some problems as they break rather easily under mechanical stresses. This paper introduces some preliminary results in design and fabrication of a non-glass solar vacuum tube collector in which the thermosyphon(heat pipe)made of copper is used as a heat transfer device. A series of tests have been performed to assess the ability of a non-glass solar vacuum tube collector. The series of experiments are as follows: 1)Vacuum level inside a vacuum tube. 2)Effects of the air remaining inside a vacuum tube on the temperature on the absorber plate. 3)Comparison of a non-glass vacuum solar collector with a single glass evacuated tube(SEIDO 5). Different vacuum levels inside non-glass vacuum tubes were applied to check any leakage or unexpected physical or chemical developments with time. The vacuum level changed from 10 -2 torr to 5torr in 5 days due to air infiltration from

  16. Measurement of triboelectric charging of moving micro particles by means of an inductive cylindrical probe

    International Nuclear Information System (INIS)

    Nesterov, A; Loeffler, F; Koenig, K; Trunk, U; Leibe, K; Felgenhauer, T; Bischoff, F R; Breitling, F; Lindenstruth, V; Stadler, V; Hausmann, M

    2007-01-01

    We present a method based on induced currents in a cylindrical probe which allows analysis of the micro-particle charging processes in an aerosol. The micro particles were triboelectrically charged by passing through a dielectric tube coaxially mounted into the probe. The cylindrical probe enabled the quantification of particle charging without prior calibration of the probe. An analytic model was developed for the description of the measured induced currents and implemented into a computer simulation program. The combination of model simulations and an appropriate experimental setup revealed comprehensive data for the determination of the particles' electric charge against time of flight through the tube. In methodological proof of principle experiments, the formations of particle clouds with charges of different signs were observed using magnetite micro particles

  17. Micro-channel plates and vacuum detectors

    Energy Technology Data Exchange (ETDEWEB)

    Gys, T., E-mail: Thierry.Gys@cern.ch

    2015-07-01

    A micro-channel plate is an array of miniature electron multipliers that are each acting as a continuous dynode chain. The compact channel structure results in high spatial and time resolutions and robustness to magnetic fields. Micro-channel plates have been originally developed for night vision applications and integrated as an amplification element in image intensifiers. These devices show single-photon sensitivity with very low noise and have been used as such for scintillating fiber tracker readout in high-energy physics experiments. Given their very short transit time spread, micro-channel plate photomultiplier tubes are also being used in time-of-flight and particle identification detectors. The present paper will cover the history of the micro-channel plate development, basic features, and some of their applications. Emphasis will be put on various new manufacturing processes that have been developed over the last few years, and that result in a significant improvement in terms of efficiency, noise, and lifetime performance.

  18. Experimental investigation of thermal storage integrated micro trigeneration system

    International Nuclear Information System (INIS)

    Johar, Dheeraj Kishor; Sharma, Dilip; Soni, Shyam Lal; Goyal, Rahul; Gupta, Pradeep K.

    2017-01-01

    Highlights: • Energy Storage System is integrated with Micro trigeneration system. • Erythritol is used as Phase Change Material. • Maximum energy saved is 15.30%. • Combined systems are feasible to increase energy efficiency. - Abstract: In this study a 4.4 kW stationary compression ignition engine is coupled with a double pipe heat exchanger, vapour absorption refrigeration system and thermal energy storage system to achieve Trigeneration i.e. power, heating and cooling. A shell and tube type heat exchanger filled with erythritol is used to store thermal energy of engine exhaust. Various combinations of thermal energy storage system integrated micro-trigeneration were investigated and results related to performance and emissions are reported in this paper. The test results show that micro capacity (4.4 kW) stationary single cylinder diesel engine can be successfully modified to simultaneously produce power, heating and cooling and also store thermal energy.

  19. Research Priorities for YouTube and Video-Sharing Technologies: A Delphi Study

    Science.gov (United States)

    Snelson, Chareen; Rice, Kerry; Wyzard, Constance

    2012-01-01

    Online video-sharing services, particularly YouTube, have gained an audience of billions of users including educators and scholars. While the academic literature provides some evidence that YouTube has been studied and written about, little is known about priorities for YouTube research. The study employed the Delphi method to obtain a consensus…

  20. Morphological and functional MR imaging of the pharyngotympanic tube

    International Nuclear Information System (INIS)

    Krombach, G.A.; Nolte-Ernsting, C.; Schmitz-Rode, T.; Guenther, R.W.; Di Martino, E.; Westhofen, M.; Prescher, A.

    2000-01-01

    Purpose: To develop and evaluate a protocol for the anatomic depiction and functional testing of the auditory tube with the use of MR imaging. Methods: Eleven volunteers were included into this study. For the morphological assessment, the imaging protocol included axial and coronal T 2 -weighted turbo-spin echo sequences (T R /T E =3194/100 ms) and a T 1 -weighted gradient echo sequence (T R /T E =42/4.6 ms). For the functional test a dynamic turbo-gradient echo sequence (TFE) with spectral fat suppression (T R /T E =15/6,2 ms; 4 sec) was obtained using the single slice technique before and during the Valsalva manoeuvre. Results: With multi-slice sequences, the osseous part of the auditory tube, the tubal cartilage (middle and lateral lamina), the ciliated epithelium, Ostmann's adipose body and the levator and tensor veli palatini muscles were delineated in all cases. During the Valsalva test, opening of the auditory tube was demonstrated in 20 of the 22 investigated sides using the dynamic TFE single slice sequence. Conclusions: The introduced MRI protocol allow visualization of the opening of the auditory tube and provides detailed anatomical information of the nasopharynx. Comprehensive morphological and functional evaluation of the auditory tube becomes possible within a single examination. (orig.) [de

  1. Study of squeeze film damping in a micro-beam resonator based on micro-polar theory

    Directory of Open Access Journals (Sweden)

    Mina Ghanbari

    Full Text Available In this paper, squeeze film damping in a micro-beam resonator based on micro-polar theory has been investigated. The proposed model for this study consists of a clamped-clamped micro-beam bounded between two fixed layers. The gap between the micro-beam and layers is filled with air. As fluid behaves differently in micro scale than macro, the micro-scale fluid field in the gap has been modeled based on micro-polar theory. Equation of motion governing transverse deflection of the micro- beam based on modified couple stress theory and also non-linear Reynolds equation of the fluid field based on micropolar theory have been non-dimensionalized, linearized and solved simultaneously in order to calculate the quality factor of the resonator. The effect of micropolar parameters of air on the quality factor has been investigated. The quality factor of the of the micro-beam resonator for different values of non-dimensionalized length scale of the beam, squeeze number and also non-dimensionalized pressure has been calculated and compared to the obtained values of quality factor based on classical theory.

  2. The compound microscope: optical tube length or parfocalization?

    International Nuclear Information System (INIS)

    Simon, J M; Comastri, S A

    2005-01-01

    In various well-known textbooks for undergraduate students of physics, the compound microscope is described as having a standardized 'optical tube length'. On the other hand, in order to fulfil the parfocalization condition required by the human visual system to understand the relation between what is viewed with and without the microscope, the distance between the object and its image through the objective must remain constant as objectives are interchanged. In this paper, we show that these two requirements are not compatible in microscopes containing a revolver with various objectives and that the 'optical tube length' (which differs from the mechanical tube length) cannot be standardized. Moreover, we consider the Deutsche Industrie Norm (DIN) and the Japanese Industry Standards (JIS) norms employed in the microscope industry for standardization of the object-to-intermediate image distance, the parfocal distance and the mechanical tube length

  3. Experimental Study on Solar Cooling Tube Using Thermal/Vacuum Emptying Method

    Directory of Open Access Journals (Sweden)

    Huizhong Zhao

    2012-01-01

    Full Text Available A solar cooling tube using thermal/vacuum emptying method was experimentally studied in this paper. The coefficient of performance (COP of the solar cooling tube was mostly affected by the vacuum degree of the system. In past research, the thermal vacuum method, using an electric oven and iodine-tungsten lamp to heat up the adsorbent bed and H2O vapor to expel the air from the solar cooling tube, was used to manufacture solar cooling tubes. This paper presents a novel thermal vacuum combined with vacuum pump method allowing an increased vacuum state for producing solar cooling tubes. The following conclusions are reached: the adsorbent bed temperature of solar cooling tube could reaches up to 233°C, and this temperature is sufficient to meet desorption demand; the refrigerator power of a single solar cooling tube varies from 1 W to 12 W; the total supply refrigerating capacity is about 287 kJ; and the COP of this solar cooling tube is about 0.215.

  4. Numerical study on turbulent heat transfer and pressure drop of nanofluid in coiled tube-in-tube heat exchangers

    International Nuclear Information System (INIS)

    Aly, Wael I.A.

    2014-01-01

    Highlights: • The performance of helically coiled tube heat exchanger using nanofluid is modeled. • The 3D turbulent flow and conjugate heat transfer of CTITHE are solved using FVM. • The effects of nanoparticle concentration and curvature ratio are investigated. • The Gnielinski correlation for Nu for turbulent flow in helical tubes can be used for water-based Al 2 O 3 nanofluid. - Abstract: A computational fluid dynamics (CFD) study has been carried out to study the heat transfer and pressure drop characteristics of water-based Al 2 O 3 nanofluid flowing inside coiled tube-in-tube heat exchangers. The 3D realizable k–ε turbulent model with enhanced wall treatment was used. Temperature dependent thermophysical properties of nanofluid and water were used and heat exchangers were analyzed considering conjugate heat transfer from hot fluid in the inner-coiled tube to cold fluid in the annulus region. The overall performance of the tested heat exchangers was assessed based on the thermo-hydrodynamic performance index. Design parameters were in the range of; nanoparticles volume concentrations 0.5%, 1.0% and 2.0%, coil diameters 0.18, 0.24 and 0.30 m, inner tube and annulus sides flow rates from 2 to 5 LPM and 10 to 25 LPM, respectively. Nanofluid flows inside inner tube side or annular side. The results obtained showed a different behavior depending on the parameter selected for the comparison with the base fluid. Moreover, when compared at the same Re or Dn, the heat transfer coefficient increases by increasing the coil diameter and nanoparticles volume concentration. Also, the friction factor increases with the increase in curvature ratio and pressure drop penalty is negligible with increasing the nanoparticles volume concentration. Conventional correlations for predicting average heat transfer and friction factor in turbulent flow regime such as Gnielinski correlation and Mishra and Gupta correlation, respectively, for helical tubes are also valid for

  5. Optical and acoustic phonon modes in strained InGaAs/GaAs rolled up tubes

    Science.gov (United States)

    Angelova, T.; Shtinkov, N.; Ivanov, Ts.; Donchev, V.; Cantarero, A.; Deneke, Ch.; Schmidt, O. G.; Cros, A.

    2012-05-01

    Rolled-up semiconductor tubes of various diameters made of alternating In0.215Ga0.785As/GaAs layers have been investigated by means of Raman scattering. The optical and acoustic phonon modes of individual tubes have been studied and compared with the characteristics of the surrounding material. After tube formation, the frequency of the phonon modes shifts with respect to the as-grown material and disorder activated modes are observed. The frequency shifts are related to the residual strain in the tubes through the deformation potential approximation. Good agreement with atomistic valence force field simulations and x-ray micro-diffraction measurements is found. By comparison with x-ray data, a Raman strain constant K = 0.65 is proposed for In0.215Ga0.785As. In the low frequency range, acoustic mode doublets are observed on the tubes that are absent in the surrounding material. They show clear evidence of the formation of periodic superlattices after the rolling-up process, and give insight into the quality of their interfaces.

  6. Micro-scale environment and mental health in later life: Results from the Cognitive Function and Ageing Study II (CFAS II).

    Science.gov (United States)

    Wu, Yu-Tzu; Prina, A Matthew; Jones, Andy; Barnes, Linda E; Matthews, Fiona E; Brayne, Carol

    2017-08-15

    Poor micro-scale environmental features, such as graffiti and broken windows, have been associated with crime and signs of social disorder with a potential impact on mental health. The aim of this study is to investigate the association between micro-scale environment and mental health problems in later life, including cognitive (cognitive impairment and dementia) and common mental disorders (depressive and anxiety symptoms). The method of visual image audits was used to collect micro-scale environmental data for 3590 participants in the Cognitive Function and Ageing Study II, a population-based multicentre cohort of people aged 65 or above in England. Multilevel logistic regression was used to examine the associations between the quality of micro-scale environment and mental health problems taking into account urban/rural difference. Poor quality of micro-scale environment was associated with nearly 20% increased odds of depressive (OR: 1.19; 95% CI: 0.99, 1.44) and anxiety symptoms (OR: 1.17; 95% CI: 0.99, 1.38) while the direction of association for cognitive disorders differed across urban and rural settings. Although higher odds of cognitive disorders were found in rural settings, living in a poor quality environment was associated with nearly twice higher odds of cognitive impairment (OR: 1.88; 95% CI: 1.18, 2.97) in urban conurbations but 20% lower odds in rural areas (OR: 0.80; 95% CI: 0.57, 1.11). The causal direction could not be fully determined due to the cross-sectional nature of the data. The visual nature of the environmental assessment tool means it likely does not fully capture features related to the availability of local support services, or opportunities for social participation and interaction. The quality of micro-scale environment appears to be important to mental health in older people. Interventions may incorporate the environmental aspect to reduce cognitive and common mental disorders. Copyright © 2017 The Authors. Published by

  7. Study for increasing micro-drill reliability by vibrating drilling

    International Nuclear Information System (INIS)

    Yang Zhaojun; Li Wei; Chen Yanhong; Wang Lijiang

    1998-01-01

    A study for increasing micro-drill reliability by vibrating drilling is described. Under the experimental conditions of this study it is observed, from reliability testing and the fitting of a life-distribution function, that the lives of micro-drills under ordinary drilling follow the log-normal distribution and the lives of micro-drills under vibrating drilling follow the Weibull distribution. Calculations for reliability analysis show that vibrating drilling can increase the lives of micro-drills and correspondingly reduce the scatter of drill lives. Therefore, vibrating drilling increases the reliability of micro-drills

  8. The use of 2D pixel detectors in micro- and nano-CT applications

    International Nuclear Information System (INIS)

    Dierick, Manuel; Hoorebeke, Luc van; Jacobs, Patric; Masschaele, Bert; Vlassenbroeck, Jelle; Cnudde, Veerle; De Witte, Yoni

    2008-01-01

    Computed tomography or CT is a non-destructive imaging technique that uses penetrating radiation (mostly X-rays) to visualize the internal structure of a sample. The best-known example is the medical CT scanner, which has become a standard diagnostic tool in medicine, providing detailed views of the body with spatial resolutions below 1 mm. In recent years another type of CT scanner has been developed for mostly industrial and scientific applications, namely micro-CT scanners. These reached spatial resolutions down to a few microns. During 2005 the Radiation Physics research group (Department of Subatomic and Radiation Physics) and the Sedimentary Geology and Engineering Geology research group (Department of Geology and Soil Science) of the Ghent University jointly developed a modular micro-CT setup. The two main goals were to achieve a spatial resolution below 1 μm and to have a very versatile tool providing high-quality images. The source is a dual-head X-ray tube with a transmission type head with a nominal focal spot size of 900 nm below 40 kV tube voltage for high-resolution applications and a directional high-power head (up to 160 kV, up to 150 W), which enables scanning of larger samples. A six-axis sample manipulator system was assembled. The crucial component in this is an ultra-high-precision air-bearing rotation stage to keep all motion errors during rotation well below 1 μm. Depending on the application we have the choice between a number of detectors, each with its own advantages in terms of size, pixel resolution and energy sensitivity

  9. Carbon-based micro-ball and micro-crystal deposition using filamentary pulsed atmospheric pressure plasma

    International Nuclear Information System (INIS)

    Pothiraja, Ramasamy; Bibinov, Nikita; Awakowicz, Peter

    2014-01-01

    Thin plasma filaments are produced by the propagation of ionization waves from a spiked driven electrode in a quartz tube in an argon/methane gas mixture (2400 sccm/2 sccm) at atmospheric pressure. The position of the touch point of filaments on the substrate surface is controlled in our experiment by applying various suitable substrate configurations and geometries of the grounded electrode. The gas conditions at the touch point are varied from argon to ambient air. Based on microphotography and discharge current waveforms, the duration of the filament touching the substrate is estimated to be about one microsecond. Carbon-based materials are deposited during this time at the touch points on the substrate surface. Micro-balls are produced if the filament touch points are saved from ambient air by the argon flow. Under an air admixture, micro-crystals are formed. The dimension of both materials is approximately one micrometre (0.5–2 µm) and corresponds to about 10 10 –10 12 carbon atoms. Neither the diffusion of neutral species nor drift of ions can be reason for the formation of such a big micro-material during this short period of filament–substrate interaction. It is possible that charged carbon-based materials are formed in the plasma channel and transported to the surface of the substrate. The mechanism of this transport and characterization of micro-materials, which are formed under different gas conditions in our experiment, will be studied in the future. (paper)

  10. Heat Exchanger Tube to Tube Sheet Joints Corrosion Behavior

    Directory of Open Access Journals (Sweden)

    M. Iancu

    2013-03-01

    Full Text Available Paper presents the studies made by the authors above the tube to tube sheet fittings of heat exchanger with fixed covers from hydrofining oil reforming unit. Tube fittings are critical zones for heat exchangers failures. On a device made from material tube and tube sheet at real joints dimensions were establish axial compression force and traction force at which tube is extracted from expanded joint. Were used two shapes joints with two types of fittings surfaces, one with smooth hole of tube sheet and other in which on boring surface we made a groove. From extracted expanded tube zones were made samples for corrosion tests in order to establish the corrosion rate, corrosion potential and corrosion current in working mediums such as hydrofining oil and industrial water at different temperatures. The corrosion rate values and the temperature influence are important to evaluate joints durability and also the results obtained shows that the boring tube sheet shape with a groove on hole tube shape presents a better corrosion behavior then the shape with smooth hole tube sheet.

  11. Visual and anatomical outcomes following idiopathic macular epiretinal membrane surgery

    International Nuclear Information System (INIS)

    Shahzadi, B.; Rizvi, S.F.; Latif, K.; Naz, S.

    2016-01-01

    To assess the visual and anatomical outcomes following idiopathic macular epiretinal membrane (IERM) surgery. Study Design: Case series. Place and Duration of Study: Layton Rehmatulla Benevolent Trust (L.R.B.T), Free Base Eye Hospital, Karachi, from January 2015 to June 2016. Methodology: Thirty eyes of thirty patients affected with idiopathic macular epiretinal membrane stage 2 were enrolled in this study. They subsequently underwent 23-gauge pars plana vitrectomy (PPV) with epiretinal membrane removal without internal limiting membrane peeling. The visual outcome was measured as improvement in best corrected visual acuity (BCVA) of at least two or more lines on ETDRS chart as compared to preoperative BCVA. The anatomical outcome was measured as decrease in foveal thickness on Spectral Domain-Optical Coherence Tomography (SD-OCT). Patients were followed for a period of 06 months. Results: At the end of follow-ups, 23 (76%) eyes out of 30 gained 2 or more lines of vision. In 05 (16%) eyes, BCVA remained same and only 02 (6.6%) eyes showed worsening of vision. Mean preoperative foveal thickness was 392 ± 20 micro m, whereas mean postoperative thickness was 305 ± 16 micro m with an average decrease of 87 micro m, in foveal thickness. Recurrence of ERM was found to be the most frequent complication. Conclusion: IERM surgery is a safe procedure and beneficial in achieving significant visual acuity improvement and anatomical recovery in the majority of cases. (author)

  12. Window-assisted nanosphere lithography for vacuum micro-nano-electronics

    International Nuclear Information System (INIS)

    Li, Nannan; Pang, Shucai; Yan, Fei; Chen, Lei; Jin, Dazhi; Xiang, Wei; Zhang, De; Zeng, Baoqing

    2015-01-01

    Development of vacuum micro-nano-electronics is quite important for combining the advantages of vacuum tubes and solid-state devices but limited by the prevailing fabricating techniques which are expensive, time consuming and low-throughput. In this work, window-assisted nanosphere lithography (NSL) technique was proposed and enabled the low-cost and high-efficiency fabrication of nanostructures for vacuum micro-nano-electronic devices, thus allowing potential applications in many areas. As a demonstration, we fabricated high-density field emitter arrays which can be used as cold cathodes in vacuum micro-nano-electronic devices by using the window-assisted NSL technique. The details of the fabricating process have been investigated. This work provided a new and feasible idea for fabricating nanostructure arrays for vacuum micro-nano-electronic devices, which would spawn the development of vacuum micro-nano-electronics

  13. Study of microstructural changes in boiler tubes and usage of time approach for determining of tube's failure

    International Nuclear Information System (INIS)

    Hemasi Taherabadi, L.; Raeiatpour, M.; Mehdizadeh, M.

    2001-01-01

    Operation condition of boilers such as corrosive media, high temperature and pressure has a pronounced effect on quality and performance of its components. Among these, the effect of temperature in microstructure and degradation of mechanical properties of boiler tubes is of most importance. Change in dimension, morphology, chemical composition and carbide spacing are the most important microstructural changes. Methods of study of such changes (through the investigation of composition, carbide spacing and thermal softening) are pointed in this article. Then, a number of failed super-heater tubes of a power plant were microlithography examined. Remaining life of tubes could be estimated by comparison of the results of metallographic and replication tests with microstructural standards

  14. Study of creep collapse of tubes subject to external pressure at elevated temperature

    International Nuclear Information System (INIS)

    Takikawa, N.

    1982-01-01

    Intermediate heat exchanger (IHX) tubes of VHTR form the boundary between the primary and secondary coolants of the reactor. The tubes are subject to external pressures at a postulated secondary coolant depressurization accident, which might lead to creep collapse. Therefore, it is necessary to ensure the integrity against creep collapse by analysis. The objective of this work is to study a simplified analytical method for predicting collapse time of a curved tube subjected to an external pressure. The study is made based on the comparison of experimental collapse time of curved and straight tubes. Creep collapse tests were conducted under an elevated temperature and an external pressure. Test results showed that curved tubes had longer collapse time than straight tubes with the same cross sectional ovality. The simplified analytical method for a curved tube is proposed in this report, which is to compute collapse time of a straight tube with the same ovality. And in this method the computed time is considered as collapse time of the curved tube. The above test results show that this simplified method gives the conservative collapse time. And it is confirmed by additional IHX tube tests that the method is applicable to creep collapse analysis of IHX tubes

  15. Forming of Polymeric Tubular Micro-components

    DEFF Research Database (Denmark)

    Qin, Yi; Zhao, Jie; Anyasodor, Gerald

    2015-01-01

    platform for the production of functional polymeric tubular micro-components. The chapter gives background on the current market and process development trends, followed by description of materials, process configuration, tool design and machine development for each processing technology as well......This chapter is intended to provide an overview of three nontraditional shaping technologies for the forming of polymeric micro-tubes, which are hot embossing, blow molding, and cross rolling, as well as realization of a process chain and the integration of a modular machine-based manufacturing...... as strategy for integration of the technologies and equipment into a common platform. Finally, potential applications of the technologies and facilities developed are highlighted....

  16. Study of Cycling Air-Cooling System with a Cold Accumulator for Micro Gas-Turbine Installations

    Science.gov (United States)

    Ochkov, V. F.; Stepanova, T. A.; Katenev, G. M.; Tumanovskii, V. A.; Borisova, P. N.

    2018-05-01

    Using the cycling air-cooling systems of the CTIC type (Combustion Turbine Inlet Cooling) with a cold accumulator in a micro gas-turbine installation (micro-GTI) to preserve its capacity under the seasonal temperature rise of outside air is described. Water ice is used as the body-storage in the accumulators, and ice water (water at 0.5-1.0°C) is used as the body that cools air. The ice water circulates between the accumulator and the air-water heat exchanger. The cold accumulator model with renewable ice resources is considered. The model contains the heat-exchanging tube lattice-evaporator covered with ice. The lattice is cross-flowed with water. The criterion heat exchange equation that describes the process in the cold accumulator under consideration is presented. The calculations of duration of its active operation were performed. The dependence of cold accumulator service life on water circulation rate was evaluated. The adequacy of the design model was confirmed experimentally in the mock-up of the cold accumulator with a refrigerating machine periodically creating a 200 kg ice reserve in the reservoir-storage. The design model makes it possible to determine the weight of ice reserve of the discharged cold accumulator for cooling the cycle air in the operation of a C-30 type micro- GTI produced by the Capstone Company or micro-GTIs of other capacities. Recommendations for increasing the working capacity of cold accumulators of CTIC-systems of a micro-GTI were made.

  17. Gastrostomy Tube (G-Tube)

    Science.gov (United States)

    ... any of these problems: a dislodged tube a blocked or clogged tube any signs of infection (including redness, swelling, or warmth at the tube site; discharge that's yellow, green, or foul-smelling; fever) excessive bleeding or drainage from the tube site severe abdominal pain lasting ...

  18. YouTube in the Science Classroom

    Science.gov (United States)

    Everhart, Jerry

    2009-01-01

    YouTube makes it possible for teachers to capitalize on children's insatiable appetite for visually stimulating learning. Some of these videos attain "viral" status, getting passed on from person to person and by links on other sites. Not only are these popular videos viral, but developing one's own content and posting it for the world's access is…

  19. MicroRNA Expression in Laser Micro-dissected Breast Cancer Tissue Samples - a Pilot Study.

    Science.gov (United States)

    Seclaman, Edward; Narita, Diana; Anghel, Andrei; Cireap, Natalia; Ilina, Razvan; Sirbu, Ioan Ovidiu; Marian, Catalin

    2017-10-28

    Breast cancer continues to represent a significant public health burden despite outstanding research advances regarding the molecular mechanisms of cancer biology, biomarkers for diagnostics and prognostic and therapeutic management of this disease. The studies of micro RNAs in breast cancer have underlined their potential as biomarkers and therapeutic targets; however most of these studies are still done on largely heterogeneous whole breast tissue samples. In this pilot study we have investigated the expression of four micro RNAs (miR-21, 145, 155, 92) known to be involved in breast cancer, in homogenous cell populations collected by laser capture microdissection from breast tissue section slides. Micro RNA expression was assessed by real time PCR, and associations with clinical and pathological characteristics were also explored. Our results have confirmed previous associations of miR-21 expression with poor prognosis characteristics of breast cancers such as high stage, large and highly proliferative tumors. No statistically significant associations were found with the other micro RNAs investigated, possibly due to the small sample size of our study. Our results also suggest that miR-484 could be a suitable endogenous control for data normalization in breast tissues, these results needing further confirmation by future studies. In summary, our pilot study showed the feasibility of detecting micro RNAs expression in homogenous laser captured microdissected invasive breast cancer samples, and confirmed some of the previously reported associations with poor prognostic characteristics of breast tumors.

  20. Effects on cuytoskeleton system in pollen tube of pinus thunbergii induced by ion beam implantation

    International Nuclear Information System (INIS)

    Huang Qunce; Liang Qiuxia; Li Guopin

    2008-01-01

    The damage of the cytoskeleton system in the pollen and the pollen tube of Pinus thunbergii induced by ion beam implantation were researched. The results showed that the disorganization of the micro-tubules in the pollen tube was produced by N + implantation. The abnormal states of the pollen tube in morphology were very correlative with the abnormality of the cytoskeleton system. N + implantation was responsible for morphological abnormalities in the pollen tubes. There was a distinct correlation between the damage effects and the ion implantation dose. The add of dose caused more obvious damage effects. Furthermore, the state of the cytoskeleton system in the pollen tube was influenced by the ion implantation. The impact grade depended also on the ion implantation dose. (authors)

  1. Osseointegration of Implants Surface-Treated with Various Diameters of TiO2 Nano tubes in Rabbit

    International Nuclear Information System (INIS)

    Kang, Ch.G.; Park, Y.B.; Choi, H.; Lee, K.W.; Shim, J.S.; Oh, S.; Choi, S.H.

    2014-01-01

    The aim of this study was to evaluate the osseointegration of implants which were surface-treated with various diameters of TiO 2 nano tubes (30 nm, 70 nm, and 100 nm) in rabbit. Resorbable blast media (RBM) surfaced implants (Osstem, Busan, Korea) 3.5 mm in diameter and 8.5 mm in length were designated as the control group and the implants surface-treated with various diameters of nano tubes (30 nm, 70 nm, and 100 nm) with the same shapes were designated as the experimental groups. The implants were maintained unloaded for 4 and 12 weeks. After this period, the animals were sacrificed and micro-CT analysis, histomorphometric analysis (bone to implant contact (BIC), bone volume (BV)), and removal torque test were performed. Micro-CT analysis, histomorphometric analysis, and removal torque test results all showed the similar pattern, showing that 70 nm experimental group had the highest value at 4 weeks while 30 nm experimental group had the highest value at 12 weeks. Therefore, on the basis of the results above, it can be concluded that 30 nm and 70 nm TiO 2 nano tubes may have positive effects on osteogenesis and osseointegration depending on the healing time

  2. Simulation studies on Tube End Expansion of AA2014 Alloy Tubes

    Science.gov (United States)

    Venugopal, L.; Prasad, N. E. C.; Geeta Krishna, P.; Praveen, L.

    2018-03-01

    End forming is defined as forming the end of tubular forms either by inverting the tube or by expanding it. It finds application in many fields such as in automotive and aerospace sectors as power transmission elements, fuel lines, exhaust pipes etc. The main aim of the present work is to expand the AA2014 alloy tubes with different die sets without any fracture. Deform 2D software was used for performing simulations on expanding the tubes with different die set (punch) values having differed forming angles (α = 15°, 30° and 45°) and expansion ratios (rp/r0 = 1.39, 1.53 and 1.67). Experiments were also conducted and the results correlate with the simulation results. The results shows that for the punch having less cone angle (α) values the linear displacement is more rather than higher cone angles. But in the case of higher cone angles the radial displacement is more than the linear displacement.

  3. Micro controller application as x-ray machine's high voltage controller

    International Nuclear Information System (INIS)

    Wiranto Budi Santoso; Beny Syawaludin

    2010-01-01

    The micro controller application as x-ray machine's high voltage controller has been carried out. The purpose of this micro controller application is to give an accurate high voltage supply to the x-ray tube so that the x ray machine could produce the result as expected. The micro controller based X-ray machine's high voltage controller receives an input voltage from the keypad. This input value is displayed in the LCD (Liquid Crystal Display) screen. Then micro controller uses this input data to drive the stepper motor. The stepper motor adjusts the high voltage auto transformer's output according to the input value. The micro controller is programmed using BASCOM-B051 compiler. The test results show that the stepper motor could rotate according to an input value. (author)

  4. MEMS-based Micro Coriolis mass flow sensor

    NARCIS (Netherlands)

    Haneveld, J.; Brouwer, Dannis Michel; Mehendale, A.; Zwikker, R.; Lammerink, Theodorus S.J.; de Boer, Meint J.; Wiegerink, Remco J.

    2008-01-01

    We have realized a micromachined micro Coriolis flow sensor consisting of a silicon nitride resonant tube of 40 μm diameter and 1.2 μm wall thickness. First measurements with both gas and liquid flows have demonstrated an unprecedented mass flow resolution in the order of 10 mg/hr at a full scale

  5. Shock wave attenuation in a micro-channel

    Science.gov (United States)

    Giordano, J.; Perrier, P.; Meister, L.; Brouillette, M.

    2018-05-01

    This work presents optical measurements of shock wave attenuation in a glass micro-channel. This transparent facility, with a cross section ranging from 1 mm× 150 μm to 1 mm× 500 μm, allowed for the use of high-speed schlieren videography to visualize the propagation of a shock wave within the entire micro-channel and to quantify velocity attenuation of the wave due to wall effects. In this paper, we present the experimental technique and the relevant data treatment we have used to increase the sensitivity of shock wave detection. Then, we compared our experimental results for different channel widths, lengths, and shock wave velocities with the analytical model for shock attenuation proposed by Russell (J Fluid Mech 27(2):305-314, 1967), which assumes laminar flow, and by Mirels (Attenuation in a shock tube due to unsteady-boundary-layer action, NACA Report 1333, 1957) for turbulent flow. We found that these models are inadequate to predict the observed data, owing to the presence of fully developed flow which violates the basic assumption of these models. The data are also compared with the empirical shock attenuation models proposed by Zeitoun (Phys Fluids 27(1):011701, 2015) and Deshpande and Puranik (Shock Waves 26(4):465-475, 2016), where better agreement is observed. Finally, we presented experimental data for the flow field behind the shock wave from measurements of the Mach wave angle which shows globally decreasing flow Mach numbers due to viscous wall effects.

  6. Feasibility of Optical Coherence Tomography (OCT for Intra-Operative Detection of Blood Flow during Gastric Tube Reconstruction

    Directory of Open Access Journals (Sweden)

    Sanne M. Jansen

    2018-04-01

    Full Text Available In this study; an OCT-based intra-operative imaging method for blood flow detection during esophagectomy with gastric tube reconstruction is investigated. Change in perfusion of the gastric tube tissue can lead to ischemia; with a high morbidity and mortality as a result. Anastomotic leakage (incidence 5–20% is one of the most severe complications after esophagectomy with gastric tube reconstruction. Optical imaging techniques provide for minimal-invasive and real-time visualization tools that can be used in intraoperative settings. By implementing an optical technique for blood flow detection during surgery; perfusion can be imaged and quantified and; if needed; perfusion can be improved by either a surgical intervention or the administration of medication. The feasibility of imaging gastric microcirculation in vivo using optical coherence tomography (OCT during surgery of patients with esophageal cancer by visualizing blood flow based on the speckle contrast from M-mode OCT images is studied. The percentage of pixels exhibiting a speckle contrast value indicative of flow was quantified to serve as an objective parameter to assess blood flow at 4 locations on the reconstructed gastric tube. Here; it was shown that OCT can be used for direct blood flow imaging during surgery and may therefore aid in improving surgical outcomes for patients.

  7. Micro-radiography of biological samples with medical contrast agents

    International Nuclear Information System (INIS)

    Dammer, J.; Weyda, F.; Benes, J.; Sopko, V.; Gelbic, I.

    2013-01-01

    Micro-radiography is an imaging technique that uses X-rays to study the internal structures of objects. This fast and easy imaging tool is based on differential X-ray attenuation by various tissues and structures within biological samples. The experimental setup described is based on the semiconductor pixel X-ray detector Medipix2 and X-ray micro-focus tube. Our micro-radiographic system has been recently used not only for the examination of internal structures of various arthropods and other biological objects but also for tracing some processes in selected model species (we used living larvae of mosquito Culex quinquefasciatus). Low concentrations of iodine, lanthanum or gold particles were used as a tracer (contrast agent). Such contrast agents increase the absorption of X-rays and allow a better visibility of internal structures of model organisms (especially the various cavities, pores, etc.). In addition, the movement of tracers in selected timing experiments demonstrates some physiological functions of digestive and excretory system

  8. Micro-radiography of biological samples with medical contrast agents

    Energy Technology Data Exchange (ETDEWEB)

    Dammer, J., E-mail: jiri.dammer@lf1.cuni.cz [Charles University in Prague, First Faculty of Medicine, Salmovská 1, 120 00 Prague 2 (Czech Republic); Hospital Na Bulovce, Department of Radiological Physics, Budinova 2, 180 81 Prague 8 (Czech Republic); Institute of Experimental and Applied Physics, Czech Technical University in Prague, Horska 3a/22, 128 00 Prague 2 (Czech Republic); Weyda, F. [Faculty of Science, University of South Bohemia, Branisovska 31, 370 05 Ceske Budejovice (Czech Republic); Benes, J. [Charles University in Prague, First Faculty of Medicine, Salmovská 1, 120 00 Prague 2 (Czech Republic); Sopko, V. [Hospital Na Bulovce, Department of Radiological Physics, Budinova 2, 180 81 Prague 8 (Czech Republic); Institute of Experimental and Applied Physics, Czech Technical University in Prague, Horska 3a/22, 128 00 Prague 2 (Czech Republic); Gelbic, I. [Biology Centre, AS CR, Institute of Entomology, Department of Biochemistry and Physiology, Branisovska 31, CZ-37005 Ceske Budejovice (Czech Republic)

    2013-12-01

    Micro-radiography is an imaging technique that uses X-rays to study the internal structures of objects. This fast and easy imaging tool is based on differential X-ray attenuation by various tissues and structures within biological samples. The experimental setup described is based on the semiconductor pixel X-ray detector Medipix2 and X-ray micro-focus tube. Our micro-radiographic system has been recently used not only for the examination of internal structures of various arthropods and other biological objects but also for tracing some processes in selected model species (we used living larvae of mosquito Culex quinquefasciatus). Low concentrations of iodine, lanthanum or gold particles were used as a tracer (contrast agent). Such contrast agents increase the absorption of X-rays and allow a better visibility of internal structures of model organisms (especially the various cavities, pores, etc.). In addition, the movement of tracers in selected timing experiments demonstrates some physiological functions of digestive and excretory system.

  9. Experimental investigation and exergy analysis on thermal storage integrated micro-cogeneration system

    International Nuclear Information System (INIS)

    Johar, Dheeraj Kishor; Sharma, Dilip; Soni, Shyam Lal; Gupta, Pradeep K.; Goyal, Rahul

    2017-01-01

    Highlights: • Energy Storage System is integrated with Micro cogeneration system. • Erythritol is used as Phase Change Material. • Maximum energy saved is 15.2%. • Maximum exergy saved is 4.22%. • Combined systems are feasible to increase energy and exergy efficiency. - Abstract: This paper describes the performance of thermal storage integrated micro-cogeneration system based on single cylinder diesel engine. In addition to electricity generated from genset, waste heat from hot exhaust of diesel engine was used to heat water in a double pipe heat exchanger of 67.70 cm length with inside tube diameter of 3.81 cm and outside tube diameter of 5.08 cm. Additionally, a latent heat thermal energy storage system was also integrated with this cogeneration system. A shell and tube type heat exchanger of 346 mm diameter and 420 mm height with 45 tubes of 18 mm diameter each was designed and fabricated, to store thermal energy, in which Erythritol (C_4H_1_0O_4) was used as phase changing material. The test results show that micro capacity (4.4 kW), stationary, single cylinder, diesel engine can be successfully utilized to simultaneously produce power as well as heating, and to also store thermal energy. Slight decrease in engine performance was observed when double pipe heat exchanger and latent heat thermal energy storage system was integrated with engine but the amount of energy which could be recovered was significant. Maximum percentage of energy saved was obtained at a load of 3.6 kW and was 15.2%.

  10. Visual Semiotics & Uncertainty Visualization: An Empirical Study.

    Science.gov (United States)

    MacEachren, A M; Roth, R E; O'Brien, J; Li, B; Swingley, D; Gahegan, M

    2012-12-01

    This paper presents two linked empirical studies focused on uncertainty visualization. The experiments are framed from two conceptual perspectives. First, a typology of uncertainty is used to delineate kinds of uncertainty matched with space, time, and attribute components of data. Second, concepts from visual semiotics are applied to characterize the kind of visual signification that is appropriate for representing those different categories of uncertainty. This framework guided the two experiments reported here. The first addresses representation intuitiveness, considering both visual variables and iconicity of representation. The second addresses relative performance of the most intuitive abstract and iconic representations of uncertainty on a map reading task. Combined results suggest initial guidelines for representing uncertainty and discussion focuses on practical applicability of results.

  11. Experimental study on two-phase flow in horizontal duct using a visualization technique; Estudo experimental de escoamentos bifasicos em duto horizontal usando uma tecnica de visualizacao

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Livia A.; Tomas, Bruno T.; Cunha Filho, Jurandyr S.; Su, Jian, E-mail: livia.alves.oliveira@gmail.co [Coordenacao dos Programas de Pos-graduacao de Engenharia (COPPE/UFRJ), Rio de Janeiro, RJ (Brazil). Programa de Engenharia Nuclear; Faccini, Jose L.H. [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2009-07-01

    In this paper an experimental study is performed for visualization of water-air two phase flow, stratified and intermittent, in a 51 mm internal diameter circular section horizontal tube. The study consists in filming a water-air mixture passin by a transparent interval of the tube, using a high speed camera. After that, the obtained images are analysed frame after frame and then, data are extracted of weight of gas-liquid interfaces, length and gas bubbles speeds. Then, these data are verified with experimental and theoretical correlations available in the literature

  12. Three-dimensional measurement and visualization of internal flow of a moving droplet using confocal micro-PIV.

    Science.gov (United States)

    Kinoshita, Haruyuki; Kaneda, Shohei; Fujii, Teruo; Oshima, Marie

    2007-03-01

    This paper presents a micro-flow diagnostic technique, 'high-speed confocal micro-particle image velocimetry (PIV)', and its application to the internal flow measurement of a droplet passing through a microchannel. A confocal micro-PIV system has been successfully constructed wherein a high-speed confocal scanner is combined with the conventional micro-PIV technique. The confocal micro-PIV system enables us to obtain a sequence of sharp and high-contrast cross-sectional particle images at 2000 frames s(-1). This study investigates the confocal depth, which is a significant parameter to determine the out-of-plane measurement resolution in confocal micro-PIV. Using the present confocal micro-PIV system, we can measure velocity distributions of micro-flows in a 228 microm x 171 microm region with a confocal depth of 1.88 microm. We also propose a three-dimensional velocity measurement method based on the confocal micro-PIV and the equation of continuity. This method enables us to measure three velocity components in a three-dimensional domain of micro flows. The confocal micro-PIV system is applied to the internal flow measurement of a droplet. We have measured three-dimensional distributions of three-component velocities of a droplet traveling in a 100 microm (width) x 58 microm (depth) channel. A volumetric velocity distribution inside a droplet is obtained by the confocal micro-PIV and the three-dimensional flow structure inside the droplet is investigated. The measurement results suggest that a three-dimensional and complex circulating flow is formed inside the droplet.

  13. Temporal comparison of ultrasound vs. auscultation and capnography in verification of endotracheal tube placement.

    Science.gov (United States)

    Pfeiffer, P; Rudolph, S S; Børglum, J; Isbye, D L

    2011-11-01

    This study compared the time consumption of bilateral lung ultrasound with auscultation and capnography for verifying endotracheal intubation. A prospective, paired, and investigator-blinded study carried out in the operating theatre. Twenty-five adult patients requiring endotracheal intubation were included. During intubation, transtracheal ultrasound was performed to visualize passage of the endotracheal tube. During bag ventilation, bilateral lung ultrasound was performed for the detection of lung sliding as a sign of ventilation simultaneous with capnography and auscultation of the epigastrium and chest. Primary outcome measure was time difference to confirmed endotracheal intubation between ultrasound and auscultation alone. Secondary outcome measure was time difference between ultrasound and auscultation combined with capnography. Both methods verified endotracheal tube placement in all patients. In 68% of patients, endotracheal tube placement was visualized by real-time transtracheal ultrasound. Comparing ultrasound with the combination of auscultation and capnography, there was a significant difference between the two methods. Median time for ultrasound was 40 s [interquartile range (IQR) 35-48 s] vs. 48 s (IQR 45-53 s), P auscultation alone. Median time for auscultation alone was 42 s (IQR 37-47 s), P = 0.6, with a mean difference of -0.88 s in favour of ultrasound (95% CI -4.2-2.5 s). Verification of endotracheal tube placement with ultrasound is as fast as auscultation alone and faster than the standard method of auscultation and capnography. © 2011 The Authors. Acta Anaesthesiologica Scandinavica © 2011 The Acta Anaesthesiologica Scandinavica Foundation.

  14. Analysis of the State of Steam Generator Tubes

    International Nuclear Information System (INIS)

    Bergunker, Olga

    2008-01-01

    The problem of safe operation of SG heat exchanging tubes, of both economical and effective control of their state is still important these days. Issues connected with peculiarities of methods of SG tubes inspection, automated analysis of the inspection results, tubes state analysis and development of algorithms of forecasting their state are considered in this report. The need for effective use of extensive data arrays on SG operation has led to the necessity of creating software tools for collection, storage and analysis of these data. The data-analytical system 'NPP Steam Generators' meant for data systematization and visualization as well as various types of analyses of data on eddy current inspection of WWER-440 and WWER-1000 SG tubes is presented in this report. The main possibilities of the data-analytical system (DAS), the code current state and prospects of its development are shown. The main fields of DAS application are considered and some results of its practical use are mentioned, namely, in the field of forecasting SG tubes state. (authors)

  15. Microstructure evolution in TRIP-aided seamless steel tube during T-shape hydroforming process

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Jiyuan [State Key Laboratory of Rolling and Automation, Northeastern University, Shenyang 110004, Liaoning Provence (China); Zhang, Zicheng, E-mail: zhangzicheng2004@126.com [School of Mechanical Engineering and Automation, Northeastern University, Shenyang 110004, Liaoning Provence (China); Manabe, Ken-ichi [Department of Mechanical Engineering, Tokyo Metropolitan University, 1-1 Minami-Osawa, Hachioji-shi, Tokyo 192-0397 (Japan); Li, Yanmei [State Key Laboratory of Rolling and Automation, Northeastern University, Shenyang 110004, Liaoning Provence (China); Misra, R.D.K. [Center for Structural and Functional Materials, University of Louisiana at Lafayette, 44130 Lafayette, LA 70504-4130 (United States)

    2014-08-15

    Transformation-induced plasticity aided seamless steel tube comprising of ferrite, bainite, and metastable austenite was processed through forging, piercing, cold-drawing, and two-stage heat treatment. T-shape hydroforming is a classic forming method for experimental research and practical production. The current work studied austenite-to-martensite transformation and microcrack initiation and propagation of the tube during T-shape hydroforming using electron backscattering diffraction, scanning electron microscopy, and transmission electron microscopy. The strain distribution in the bcc-phase and fcc-phase was studied by evaluating changes in the average local misorientation. Compared to the compressive stress, metastable austenite with similar strain surrounding or inside the grains transformed easier under tensile loading conditions. The inclusions were responsible for microcrack initiation. The propagation of the cracks is hindered by martensite/austenite constituent due to transformation induced plasticity effect. The volume fraction of untransformed retained austenite decreased with increase in strain implying transformation-induced plasticity effect. - Highlights: • Hydroformed tubes processed via TRIP concept • EBSD provided estimate of micro local strain. • Retained austenite hinders propagation of microcracks.

  16. Best practice strategies for validation of micro moulding process simulation

    DEFF Research Database (Denmark)

    Costa, Franco; Tosello, Guido; Whiteside, Ben

    2009-01-01

    are the optimization of the moulding process and of the tool using simulation techniques. Therefore, in polymer micro manufacturing technology, software simulation tools adapted from conventional injection moulding can provide useful assistance for the optimization of moulding tools, mould inserts, micro component...... are discussed. Recommendations regarding sampling rate, meshing quality, filling analysis methods (micro short shots, flow visualization) and machine geometry modelling are given on the basis of the comparison between simulated and experimental results within the two considered study cases.......Simulation programs in polymer micro replication technology are used for the same reasons as in conventional injection moulding. To avoid the risks of costly re-engineering, the moulding process is simulated before starting the actual manufacturing process. Important economic factors...

  17. Experiments on condensation heat transfer characteristics inside a microfin tube with R410A

    Energy Technology Data Exchange (ETDEWEB)

    Han, D H; Cho, Y J [Korea University Graduate School, Seoul (Korea); Lee, K J; Park, S S [Korea University, Seoul (Korea)

    2000-11-01

    Due to the ozone depletion and global warming potentials, some refrigerants (CFCs and HCFCs) have been rapidly substituted. R410A is considered as the alternative refrigerant of R22 for the air-conditioners used at home and in industry. Experiments on the condensation heat transfer characteristics inside a smooth or a micro-fin tube with R410A are performed in this study. The test tubes 7/9.52 mm in outer diameters and 3 m in length are used. Varying the mass flux of the refrigerant and the condensation temperatures, the average heat transfer coefficients and pressure drop are investigated. It is shown that the heat transfer is enhanced and the amount of pressure drops are larger in the microfin tube than the smooth tube. From the heat transfer enhancement coefficient and the pressure penalty factor, it is found that the high heat transfer enhancement coefficients are obtained in the range of small mass flux while the penalty factors are almost equal. (author). 13 refs., 12 figs., 1 tab.

  18. Failure analysis of boiler tubes in lakhra coal power plant

    International Nuclear Information System (INIS)

    Shah, A.; Baluch, M.M.; Ali, A.

    2010-01-01

    Present work deals with the failure analysis of a boiler tube in Lakhra fluidized bed combustion power station. Initially, visual inspection technique was adopted to analyse the fractured surface. Detailed microstructural investigations of the busted boiler tube were carried out using light optical microscope and scanning electron microscope. The hardness tests were also performed. A 50 percent decrease in hardness of intact portion of the tube material and from area adjacent to failure was measured, which was found to be in good agreement with the wall thicknesses measured of the busted boiler tube i.e. 4 mm and 2 mm from unaffected portion and ruptured area respectively. It was concluded that the major cause of failure of boiler tube is erosion of material which occurs due the coal particles strike at the surface of the tube material. Since the temperature of boiler is not maintained uniformly. The variations in boiler temperature can also affect the material and could be another reason for the failure of the tube. (author)

  19. Analytical study of condensation heat transfer on titanium tube with super-hydrophobic surface

    Energy Technology Data Exchange (ETDEWEB)

    Ji, Dae Yun; Park, Hyun Gyu; Lee, Kwon Yeong [Handong Global University, Pohang (Korea, Republic of)

    2016-05-15

    There are many nuclear or fossil power plants which occupy more than 85% among entire power plants in the world. These plants release heat through condenser into nature. The condenser is an important component for cooling the working fluid after the turbine. Its performance is related with material and size of its tubes. To have good performance or to reduce condenser size, it is important to increase condensation heat transfer coefficient on condenser tubes. Ma et al. executed heat transfer experiment in dropwise condensation with non-condensable gas, and studied how the amount of air and pressure difference affect condensation heat transfer coefficient. The more non-condensable gas existed, the condensation heat transfer coefficient was decreased. Shen et al. studied condensation heat transfer at horizontal bundle tubes. Several variables such as coolant velocity, saturated pressure, and surface conditions were studied. As a result, surface modified brass tube and stainless tube showed higher condensation heat transfer coefficient as much as 1.3 and 1.4 times comparing with their bare tubes, in 70 kPa vacuum condition respectively. Rausch et al. studied dropwise condensation on ion-implanted titanium surface. Experimental study is performed to evaluate the performance of surface modified titanium tube in vacuum state. SAM coating is used to make super-hydrophobic surface of titanium tube. Preliminary analysis were performed considering filmwise and dropwise condensations, respectively. Experiment facility is almost prepared and the test result will be shown soon.

  20. Study on tube rupture strength evaluation method for rapid overheating

    International Nuclear Information System (INIS)

    Komine, Ryuji; Wada, Yusaku

    1998-08-01

    A sodium-water reaction derived from the single tube break in steam generator might overheat neighbor tubes rapidly under internal pressure loadings. If the temperature of tube wall becomes too high, it has to be evaluated that the stress of tube does not exceed the material strength limit to prevent the propagation of tube rupture. In the present study this phenomenon was recognized as the fracture of cylindrical tube with the large deformation due to overheating, and the evaluation method was investigated based on both of experimental and analytical approaches. The results obtained are as follows. (1) As for the nominal stress estimation, it was clarified through the experimental data and the detailed FEM elasto-plastic large deformation analysis that the formula used in conventional designs can be applied. (2) Within the overheating temperature limits of tubes, the creep effect is dominant, even if the loading time is too short. So the strain rate on the basis of JIS elevated temperature tensile test method for steels and heat-resisting alloys is too late and almost of total strain is composed by creep one. As a result the time dependent effect cannot be evaluated under JIS strain rate condition. (3) Creep tests in shorter time condition than a few minutes and tensile tests in higher strain rate condition than 10%/min of JIS are carried out for 2 1/4Cr-1Mo(NT) steel, and the standard values for tube rupture strength evaluation are formulated. (4) The above evaluation method based on both of the stress estimation and the strength standard values application is justified by using the tube burst test data under internal pressure. (5) The strength standard values on Type 321 ss is formulated in accordance with the procedure applied for 2 1/4Cr-1Mo(NT) steel. (author)

  1. Micro-PIV (micro particle image velocimetry) visualization of red blood cells (RBCs) sucked by a female mosquito

    International Nuclear Information System (INIS)

    Kikuchi, K; Mochizuki, O

    2011-01-01

    A mosquito's pump is a highly effective system in the small suction domain. To understand a mosquito's blood suction mechanism, we analysed the characteristics of red blood cells (RBCs) in human blood during and after suction by a female mosquito. Focussing on the flow patterns of the RBCs in human blood being sucked by a mosquito, we visualized blood flow by using a micro-particle image velocimetry (μ-PIV) system, which combines an optical microscope and a PIV method. In an ex vivo experiment, a female mosquito was supplied diluted blood at the tip of the proboscis. We examined the blood flow around the tip of the proboscis and observed that RBCs were periodically sucked towards a hole around the tip. The sucked RBCs then homogeneously flowed parallel to the inner surface of the proboscis without adhering to the wall. Furthermore, using a bioelectric recording system, we directly measured electrical signals generated during suction by the pump muscles located in the mosquito's head. We found that the electrical signal power was synchronized with the acceleration of the RBCs in the sucking phase. A histological stain method was adapted for the observation of the form and internal structure of RBCs in the mosquito. Although the blood flow analysis revealed that the RBCs underwent shear stress during suction, RBCs in the mosquito's stomach maintained their original shape

  2. Study on Reflected Shock Wave/Boundary Layer Interaction in a Shock Tube

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dong Wook; Kim, Tae Ho; Kim, Heuy Dong [Andong Nat’l Univ., Andong (Korea, Republic of)

    2017-07-15

    The interaction between a shock wave and a boundary layer causes boundary layer separation, shock train, and in some cases, strong unsteadiness in the flow field. Such a situation is also observed in a shock tube, where the reflected shock wave interacts with the unsteady boundary layer. However, only a few studies have been conducted to investigate the shock train phenomenon in a shock tube. In the present study, numerical studies were conducted using the two-dimensional axisymmetric domain of a shock tube, and compressible Navier-Stokes equations were solved to clarify the flow characteristics of shock train phenomenon inside a shock tube. A detailed wave diagram was developed based on the present computational results, which were validated with existing experimental data.

  3. In vivo laser-based imaging of the human fallopian tube for future cancer detection

    Science.gov (United States)

    Seibel, Eric J.; Melville, C. David; Johnston, Richard S.; Gong, Yuanzheng; Agnew, Kathy; Chiang, Seine; Swisher, Elizabeth M.

    2015-03-01

    Inherited mutations in BRCA1 and BRCA2 lead to 20-50% lifetime risk of ovarian, tubal, or peritoneal carcinoma. Clinical recommendations for women with these genetic mutations include the prophylactic removal of ovaries and fallopian tubes by age 40 after child-bearing. Recent findings suggest that many presumed ovarian or peritoneal carcinomas arise in fallopian tube epithelium. Although survival rate is screening techniques have mistakenly focused on the ovary as origin of ovarian carcinoma. Unlike ovaries, the fallopian tubes are amenable to direct visual imaging without invasive surgery, using access through the cervix. To develop future screening protocols, we investigated using our 1.2- mm diameter, forward-viewing, scanning fiber endoscope (SFE) to image luminal surfaces of the fallopian tube before laparoscopic surgical removal. Three anesthetized human subjects participated in our protocol development which eventually led to 70-80% of the length of fallopian tubes being imaged in scanning reflectance, using red (632nm), green (532nm), and blue (442nm) laser light. A hysteroscope with saline uterine distention was used to locate the tubal ostia. To facilitate passage of the SFE through the interstitial portion of the fallopian tube, an introducer catheter was inserted 1- cm through each ostia. During insertion, saline was flushed to reduce friction and provide clearer viewing. This is likely the first high-resolution intraluminal visualization of fallopian tubes.

  4. The root caused analysis of leakaged heat exchanger tube; Ursachenanalyse einer Leckage an einem Waermeuebertraegerrohr

    Energy Technology Data Exchange (ETDEWEB)

    Shamsudin, Shaiful Rizam; Salleh, M.A.A. Mohd; Rahmat, Azmi; Anuar, Mohd Arif [Universiti Malaysia Perlis (UniMAP) (Malaysia). Center of Excellence Geopolymer and Green Technology (CEGeoGTech); Harun, Mohd; Zayid, Hafizal [Malaysian Nuclear Agency, Selangor (Malaysia). Industry Technology Div.; Noor, Mazlee Mohd [Universiti Malaysia Perlis (UniMAP) (Malaysia). School of Materials Engineering

    2015-05-01

    AISI type 316L stainless steel was used as a heat exchanger tube material in an inter-cooler column. After less than a year of operation, severe corrosion failures occurred and a transverse opening leakage was observed on one of the heat exchanger tubes. The failed tube was carefully analyzed using various metallurgical laboratory equipments. The root cause of the tube leakage was believed due to the presence of horizontal micro and macro pores as a hydrogen gas entrapment during casting of the parent ingot. The overlapped and gaping pores formed notch on the shell side of the tube surface, and it increasingly evident when the use of a high-energy water-jet and metal brush as cleaning procedure results in an establishment of pitting type local-action corrosion cells penetrated the tube wall. As a result, corrosive fluid in the tube side dissolved into the cooling water, accelerating the corrosion process.

  5. Use of CATHENA to model calandria-tube/moderator heat transfer after pressure-tube/calandria-tube ballooning contact

    International Nuclear Information System (INIS)

    Fan, H.Z.; Bilanovic, Z.; Nitheanandan, T.

    2004-01-01

    A study was performed to assess the effect of the calandria-tube/moderator heat transfer after pressure-tube/calandria tube ballooning contact using CATHENA. Results of this study indicated that the analytical tool, CATHENA, can be applied for pool boiling heat transfer on the external surface of a large diameter tube, such as the calandria tube used in CANDU reactors. The methodology in such CANDU-generic study can be used to simulate the tube surface with multiple boiling regimes and to assess the benefits of closely coupling thermalhydraulics modelling and fuel/fuel channel behaviour modelling. CATHENA (Canadian Algorithm for THErmalhydraulic Network Analysis) is a one-dimensional, two-fluid thermalhydraulic simulation code designed by AECL to analyse two-phase flow and heat transfer in piping networks. The detailed heat transfer package in CATHENA allows a connection to be established from the multiple solid surfaces of tubes to the surrounding large amount of moderator water, which acts as a heat sink during a postulated loss of coolant event. The generalized heat transfer package within CATHENA allows the tube walls to be divided into several layers in the radial direction and several sectors in the circumferential direction, to account for heat transfer conditions in these two directions. The CATHENA code with the generalized heat transfer package is capable of capturing key pool-boiling phenomena such as nucleate, transition and film boiling heat transfer as well as an ability to model the rewet phenomenon to some extent. A CATHENA input model was generated and used in simulations of selected contact boiling experiment test cases. The transient wall temperatures have been calculated in different portions of the calandria tube. By using this model an adequate agreement was achieved between CATHENA calculation and experimental measurement The CATHENA code enables one to investigate the transient and local thermal-mechanical behaviour of the calandria tube

  6. The application of micro-coil NMR probe technology to metabolomics of urine and serum

    International Nuclear Information System (INIS)

    Grimes, John H.; O’Connell, Thomas M.

    2011-01-01

    Increasing the sensitivity and throughput of NMR-based metabolomics is critical for the continued growth of this field. In this paper the application of micro-coil NMR probe technology was evaluated for this purpose. The most commonly used biofluids in metabolomics are urine and serum. In this study we examine different sample limited conditions and compare the detection sensitivity of the micro-coil with a standard 5 mm NMR probe. Sample concentration is evaluated as a means to leverage the greatly improved mass sensitivity of the micro-coil probes. With very small sample volumes, the sensitivity of the micro-coil probe does indeed provide a significant advantage over the standard probe. Concentrating the samples does improve the signal detection, but the benefits do not follow the expected linear increase and are both matrix and metabolite specific. Absolute quantitation will be affected by concentration, but an analysis of relative concentrations is still possible. The choice of the micro-coil probe over a standard tube based probe will depend upon a number of factors including number of samples and initial volume but this study demonstrates the feasibility of high-throughput metabolomics with the micro-probe platform.

  7. Experimental study of thermal–hydraulic performance of cam-shaped tube bundle with staggered arrangement

    International Nuclear Information System (INIS)

    Bayat, Hamidreza; Lavasani, Arash Mirabdolah; Maarefdoost, Taher

    2014-01-01

    Highlights: • Thermal–hydraulic performance of a non-circular tube bundle has been investigated experimentally. • Tubes were mounted in staggered arrangement with two longitudinal pitch ratios 1.5 and 2. • Drag coefficient and Nusselt number of tubes in second row was measured. • Friction factor of this tube bundle is lower than circular tube bundle. • Thermal–hydraulic performance of this tube bundle is greater than circular tube bundle. - Abstract: Flow and heat transfer from cam-shaped tube bank in staggered arrangement is studied experimentally. Tubes were located in test section of an open loop wind tunnel with two longitudinal pitch ratios 1.5 and 2. Reynolds number varies in range of 27,000 ⩽ Re D ⩽ 42,500 and tubes surface temperature is between 78 and 85 °C. Results show that both drag coefficient and Nusselt number depends on position of tube in tube bank and Reynolds number. Tubes in the first column have maximum value of drag coefficient, while its Nusselt number is minimum compared to other tubes in tube bank. Moreover, pressure drop from this tube bank is about 92–93% lower than circular tube bank and as a result thermal–hydraulic performance of this tube bank is about 6 times greater than circular tube bank

  8. Spectral optimization for micro-CT

    International Nuclear Information System (INIS)

    Hupfer, Martin; Nowak, Tristan; Brauweiler, Robert; Eisa, Fabian; Kalender, Willi A.

    2012-01-01

    Purpose: To optimize micro-CT protocols with respect to x-ray spectra and thereby reduce radiation dose at unimpaired image quality. Methods: Simulations were performed to assess image contrast, noise, and radiation dose for different imaging tasks. The figure of merit used to determine the optimal spectrum was the dose-weighted contrast-to-noise ratio (CNRD). Both optimal photon energy and tube voltage were considered. Three different types of filtration were investigated for polychromatic x-ray spectra: 0.5 mm Al, 3.0 mm Al, and 0.2 mm Cu. Phantoms consisted of water cylinders of 20, 32, and 50 mm in diameter with a central insert of 9 mm which was filled with different contrast materials: an iodine-based contrast medium (CM) to mimic contrast-enhanced (CE) imaging, hydroxyapatite to mimic bone structures, and water with reduced density to mimic soft tissue contrast. Validation measurements were conducted on a commercially available micro-CT scanner using phantoms consisting of water-equivalent plastics. Measurements on a mouse cadaver were performed to assess potential artifacts like beam hardening and to further validate simulation results. Results: The optimal photon energy for CE imaging was found at 34 keV. For bone imaging, optimal energies were 17, 20, and 23 keV for the 20, 32, and 50 mm phantom, respectively. For density differences, optimal energies varied between 18 and 50 keV for the 20 and 50 mm phantom, respectively. For the 32 mm phantom and density differences, CNRD was found to be constant within 2.5% for the energy range of 21–60 keV. For polychromatic spectra and CMs, optimal settings were 50 kV with 0.2 mm Cu filtration, allowing for a dose reduction of 58% compared to the optimal setting for 0.5 mm Al filtration. For bone imaging, optimal tube voltages were below 35 kV. For soft tissue imaging, optimal tube settings strongly depended on phantom size. For 20 mm, low voltages were preferred. For 32 mm, CNRD was found to be almost independent

  9. Spectral optimization for micro-CT.

    Science.gov (United States)

    Hupfer, Martin; Nowak, Tristan; Brauweiler, Robert; Eisa, Fabian; Kalender, Willi A

    2012-06-01

    To optimize micro-CT protocols with respect to x-ray spectra and thereby reduce radiation dose at unimpaired image quality. Simulations were performed to assess image contrast, noise, and radiation dose for different imaging tasks. The figure of merit used to determine the optimal spectrum was the dose-weighted contrast-to-noise ratio (CNRD). Both optimal photon energy and tube voltage were considered. Three different types of filtration were investigated for polychromatic x-ray spectra: 0.5 mm Al, 3.0 mm Al, and 0.2 mm Cu. Phantoms consisted of water cylinders of 20, 32, and 50 mm in diameter with a central insert of 9 mm which was filled with different contrast materials: an iodine-based contrast medium (CM) to mimic contrast-enhanced (CE) imaging, hydroxyapatite to mimic bone structures, and water with reduced density to mimic soft tissue contrast. Validation measurements were conducted on a commercially available micro-CT scanner using phantoms consisting of water-equivalent plastics. Measurements on a mouse cadaver were performed to assess potential artifacts like beam hardening and to further validate simulation results. The optimal photon energy for CE imaging was found at 34 keV. For bone imaging, optimal energies were 17, 20, and 23 keV for the 20, 32, and 50 mm phantom, respectively. For density differences, optimal energies varied between 18 and 50 keV for the 20 and 50 mm phantom, respectively. For the 32 mm phantom and density differences, CNRD was found to be constant within 2.5% for the energy range of 21-60 keV. For polychromatic spectra and CMs, optimal settings were 50 kV with 0.2 mm Cu filtration, allowing for a dose reduction of 58% compared to the optimal setting for 0.5 mm Al filtration. For bone imaging, optimal tube voltages were below 35 kV. For soft tissue imaging, optimal tube settings strongly depended on phantom size. For 20 mm, low voltages were preferred. For 32 mm, CNRD was found to be almost independent of tube voltage. For 50 mm

  10. Validation study of two-microphone acoustic reflectometry for determination of breathing tube placement in 200 adult patients.

    Science.gov (United States)

    Raphael, David T; Benbassat, Maxim; Arnaudov, Dimiter; Bohorquez, Alex; Nasseri, Bita

    2002-12-01

    Acoustic reflectometry allows the construction of a one-dimensional image of a cavity, such as the airway or the esophagus. The reflectometric area-distance profile consists of a constant cross-sectional area segment (length of endotracheal tube), followed either by a rapid increase in the area beyond the carina (tracheal intubation) or by an immediate decrease in the area (esophageal intubation). Two hundred adult patients were induced and intubated, without restrictions on anesthetic agents or airway adjunct devices. A two-microphone acoustic reflectometer was used to determine whether the breathing tube was placed in the trachea or esophagus. A blinded reflectometer operator, seated a distance away from the patient, interpreted the acoustic area-distance profile alone to decide where the tube was placed. Capnography was used as the gold standard. Of 200 tracheal intubations confirmed by capnography, the reflectometer operator correctly identified 198 (99% correct tracheal intubation identification rate). In two patients there were false-negative results, patients with a tracheal intubation were interpreted as having an esophageal intubation. A total of 14 esophageal intubations resulted, all correctly identified by reflectometry, for a 100% esophageal intubation identification rate. Acoustic reflectometry is a rapid, noninvasive method by which to determine whether breathing tube placement is correct (tracheal) or incorrect (esophageal). Reflectometry determination of tube placement may be useful in airway emergencies, particularly in cases where visualization of the glottic area is not possible and capnography may fail, as in patients with cardiac arrest.

  11. Comparison of micro column technology with conventional tube methods for antibody detection

    Directory of Open Access Journals (Sweden)

    Sachin Garg

    2017-01-01

    Conclusion: MCT was found to be most efficacious when compared to CTT and tube LISS-IAT in detecting clinically significant red cell antibodies; although MCT missed 2 cases of Lea antibody which were detected by CTT and LISS-IAT.

  12. A study of swirl flow in draft tubes

    Energy Technology Data Exchange (ETDEWEB)

    Dahlhaug, Ole Gunnar

    1997-12-31

    This thesis presents measurements performed inside conical diffuser and bend, draft tubes of model hydro turbines, and draft tube of a prototype hydro turbine. Experimental results for swirling flow in conical diffuser and bend are presented in three different geometries. The axial velocity decreases at the centre of the tube at high swirl numbers because of an axial pressure gradient set up by the downstream frictional damping of the tangential velocities and the pressure increase downstream of the diffuser. Analytical models of the tangential velocity profiles are found and the radial pressure distribution calculated. Good correlation to the measured pressure distribution was achieved. Diffuser efficiency was calculated based on the equations for velocity and pressure profiles, which gave a qualified estimate of the diffuser hydraulic performance. The calculation shows that the bend reduces the efficiency by more than 30%. For a straight tube followed by a diffuser, numerical calculations were done, using K{epsilon}, RNG and RSM turbulence models for all measured swirl numbers. The K{epsilon} model gave best results for the forced vortex profile at low swirl numbers, while the RSM model gave best results at high swirl number. The turbulent kinetic energy at high swirl numbers gave the largest difference between the calculated and the measured values. Measurements on draft tubes in model turbines show the importance of good draft tube design. Prototype measurements on a Francis turbine show how the outlet draft tube flow should be measured for prototype draft tube evaluation. 54 refs., 118 figs., 2 tabs.

  13. A study of swirl flow in draft tubes

    Energy Technology Data Exchange (ETDEWEB)

    Dahlhaug, Ole Gunnar

    1998-12-31

    This thesis presents measurements performed inside conical diffuser and bend, draft tubes of model hydro turbines, and draft tube of a prototype hydro turbine. Experimental results for swirling flow in conical diffuser and bend are presented in three different geometries. The axial velocity decreases at the centre of the tube at high swirl numbers because of an axial pressure gradient set up by the downstream frictional damping of the tangential velocities and the pressure increase downstream of the diffuser. Analytical models of the tangential velocity profiles are found and the radial pressure distribution calculated. Good correlation to the measured pressure distribution was achieved. Diffuser efficiency was calculated based on the equations for velocity and pressure profiles, which gave a qualified estimate of the diffuser hydraulic performance. The calculation shows that the bend reduces the efficiency by more than 30%. For a straight tube followed by a diffuser, numerical calculations were done, using K{epsilon}, RNG and RSM turbulence models for all measured swirl numbers. The K{epsilon} model gave best results for the forced vortex profile at low swirl numbers, while the RSM model gave best results at high swirl number. The turbulent kinetic energy at high swirl numbers gave the largest difference between the calculated and the measured values. Measurements on draft tubes in model turbines show the importance of good draft tube design. Prototype measurements on a Francis turbine show how the outlet draft tube flow should be measured for prototype draft tube evaluation. 54 refs., 118 figs., 2 tabs.

  14. Plant Reproduction and the Pollen Tube Journey--How the Females Lure the Males

    Science.gov (United States)

    Lorbiecke, Rene

    2012-01-01

    The growth of pollen tubes is one of the most characteristic events in angiosperm reproduction. This article describes an activity for visualizing the journey and guidance of pollen tubes in the reproductive structures of a flowering plant. The activity uses a semi-in vivo system with rapid-cycling "Brassica rapa," also known as Fast Plants.…

  15. Effects of low-intensity pulsed ultrasound on new trabecular bone during bone-tendon junction healing in a rabbit model: a synchrotron radiation micro-CT study.

    Directory of Open Access Journals (Sweden)

    Hongbin Lu

    Full Text Available This study was designed to evaluate the effects of low-intensity pulsed ultrasound on bone regeneration during the bone-tendon junction healing process and to explore the application of synchrotron radiation micro computed tomography in three dimensional visualization of the bone-tendon junction to evaluate the microarchitecture of new trabecular bone. Twenty four mature New Zealand rabbits underwent partial patellectomy to establish a bone-tendon junction injury model at the patella-patellar tendon complex. Animals were then divided into low-intensity pulsed ultrasound treatment (20 min/day, 7 times/week and placebo control groups, and were euthanized at week 8 and 16 postoperatively (n = 6 for each group and time point. The patella-patellar tendon specimens were harvested for radiographic, histological and synchrotron radiation micro computed tomography detection. The area of the newly formed bone in the ultrasound group was significantly greater than that of control group at postoperative week 8 and 16. The high resolution three dimensional visualization images of the bone-tendon junction were acquired by synchrotron radiation micro computed tomography. Low-intensity pulsed ultrasound treatment promoted dense and irregular woven bone formation at week 8 with greater bone volume fraction, number and thickness of new trabecular bone but with lower separation. At week 16, ultrasound group specimens contained mature lamellar bone with higher bone volume fraction and thicker trabeculae than that of control group; however, there was no significant difference in separation and number of the new trabecular bone. This study confirms that low-intensity pulsed ultrasound treatment is able to promote bone formation and remodeling of new trabecular bone during the bone-tendon junction healing process in a rabbit model, and the synchrotron radiation micro computed tomography could be applied for three dimensional visualization to quantitatively evaluate

  16. Investigating the Influence of Micro-Arc Oxide Coating on Rigidity and Strength of Long Force Elements of Spacecraft

    Directory of Open Access Journals (Sweden)

    V. K. Shatalov

    2014-01-01

    Full Text Available Outboard elements (arms, towers are widely used in spacecraft structure for setting-out of a payload; their high stiffness-weight ratio provides an opportunity to decrease the mass. The deployment unit is considered as an example of outboard structure. Its strength beams work under special conditions in operation. At the transportation stage beams are under considerable vibration loads. Therefore for increasing the natural resonance frequency it is rational to increase their rigidity. Using the micro-arc oxide coating suggests itself because the modulus of elasticity of the micro-arc oxide coating is more than that of the aluminium alloy. The beams suffer considerable bending load at the step of deploying; therefore the aluminium alloy with the micro-arc oxide coating must have suitable loading capacity, in addition to increased rigidity.Influence of micro-arc oxide coating on the rigidity and strength of tubes f rom aluminium alloy is investigated. It is determined that forming the micro-arc oxide coating on thin-walled tubes with a ratio of the coating area to the cross-section area of more than 25% is the most rational. In this case the rigidity of composite material considerably exceeds the rigidity of the aluminium alloy of the same cross-section while the redistribution of stresses in the surface coating of heterogeneous elasticity cross-section doesn’t cause the sudden increase of stresses. Also forming an attainable thickness of the micro-arc oxide coating on the surface of tube from aluminium alloy will be rational solution because the increase of attainable thickness of the microarc oxide coating provides an opportunity to form it on thick-walled tubes saving an acceptable, in the context of the strength, ratio of the coating area to the overall cross-section area.Micro-arc oxidation is an advanced method to form the wear resistant, resistant to corrosion, heat-shielding and electrically insulating coatings, but depending on the

  17. 3D Surface Mapping of Capsule Fill-Tube Assemblies used in Laser-Driven Fusion Targets

    Energy Technology Data Exchange (ETDEWEB)

    Buice, E S; Alger, E T; Antipa, N A; Bhandarkar, S D; Biesiada, T A; Conder, A D; Dzenitis, E G; Flegel, M S; Hamza, A V; Heinbockel, C L; Horner, J; Johnson, M A; Kegelmeyer, L M; Meyer, J S; Montesanti, R C; Reynolds, J L; Taylor, J S; Wegner, P J

    2011-02-18

    This paper presents the development of a 3D surface mapping system used to measure the surface of a fusion target Capsule Fill-Tube Assembly (CFTA). The CFTA consists of a hollow Ge-doped plastic sphere, called a capsule, ranging in outer diameter between 2.2 mm and 2.6 mm and an attached 150 {micro}m diameter glass-core fill-tube that tapers down to a 10{micro} diameter at the capsule. The mapping system is an enabling technology to facilitate a quality assurance program and to archive 3D surface information of each capsule used in fusion ignition experiments that are currently being performed at the National Ignition Facility (NIF). The 3D Surface Mapping System is designed to locate and quantify surface features with a height of 50 nm and 300 nm in width or larger. Additionally, the system will be calibrated such that the 3D measured surface can be related to the capsule surface angular coordinate system to within 0.25 degree (1{sigma}), which corresponds to approximately 5 {micro}m linear error on the capsule surface.

  18. 3D Surface Mapping of Capsule Fill-Tube Assemblies used in Laser-Driven Fusion Targets

    International Nuclear Information System (INIS)

    Buice, E.S.; Alger, E.T.; Antipa, N.A.; Bhandarkar, S.D.; Biesiada, T.A.; Conder, A.D.; Dzenitis, E.G.; Flegel, M.S.; Hamza, A.V.; Heinbockel, C.L.; Horner, J.; Johnson, M.A.; Kegelmeyer, L.M.; Meyer, J.S.; Montesanti, R.C.; Reynolds, J.L.; Taylor, J.S.; Wegner, P.J.

    2011-01-01

    This paper presents the development of a 3D surface mapping system used to measure the surface of a fusion target Capsule Fill-Tube Assembly (CFTA). The CFTA consists of a hollow Ge-doped plastic sphere, called a capsule, ranging in outer diameter between 2.2 mm and 2.6 mm and an attached 150 (micro)m diameter glass-core fill-tube that tapers down to a 10(micro) diameter at the capsule. The mapping system is an enabling technology to facilitate a quality assurance program and to archive 3D surface information of each capsule used in fusion ignition experiments that are currently being performed at the National Ignition Facility (NIF). The 3D Surface Mapping System is designed to locate and quantify surface features with a height of 50 nm and 300 nm in width or larger. Additionally, the system will be calibrated such that the 3D measured surface can be related to the capsule surface angular coordinate system to within 0.25 degree (1σ), which corresponds to approximately 5 (micro)m linear error on the capsule surface.

  19. Experimental Study of Flow Boiling Heat Transfer in a Horizontal Microfin Tube

    OpenAIRE

    Yu, Jian; Koyama, Shigeru; Momoki, Satoru

    1995-01-01

    An experimental study on flow boiling heat transfer in a horizontal microfin tube is conducted with pure refrigerants HFC134a, HCFC123 and HCFC22 using a water-heated double-tube type test section. The test microfin tube is a copper tube having the following dimensions: 8.37mm mean inside diameter, 0.168mm fin height, 60fin number and 18 degree of helix angle. The local heat transfer coefficients for both counter and parallel flows are measured in a range of heat flux of 1 to 93W/m^2, mass ve...

  20. Flexible micro-OCT endobronchial probe for imaging of mucociliary transport (Conference Presentation)

    Science.gov (United States)

    Cui, Dongyao; Chu, Kengyeh K.; Unglert, Carolin I.; Ford, Tim N.; Carruth, Robert W.; Hyun, Daryl; Singh, Kanwarpal; Birket, Susan E.; Solomon, George M.; Rowe, Steve M.; Tearney, Guillermo J.

    2016-03-01

    Mucociliary clearance (MCC) plays a significant role in maintaining the health of human respiratory system by eliminating foreign particles trapped within mucus. Failure of this mechanism in diseases such as cystic fibrosis and chronic obstructive pulmonary disease (COPD) leads to airway blockage and lung infection, causing morbidity and mortality. The volume of airway mucus and the periciliary liquid encapsulating the cilia, in addition to ciliary beat frequency and velocity of mucociliary transport, are vital parameters of airway health. However, the diagnosis of disease pathogenesis and advances of novel therapeutics are hindered by the lack of tools for visualization of ciliary function in vivo. Our laboratory has previously developed a 1-µm resolution optical coherence tomography method, termed Micro-OCT, which is capable of visualizing mucociliary transport and quantitatively capturing epithelial functional metrics. We have also miniaturized Micro-OCT optics in a first-generation rigid 4mm Micro-OCT endoscope utilizing a common-path design and an apodizing prism configuration to produce an annular profile sample beam, and reported the first in vivo visualization of mucociliary transport in swine. We now demonstrate a flexible 2.5 mm Micro-OCT probe that can be inserted through the instrument channel of standard flexible bronchoscopes, allowing bronchoscopic navigation to smaller airways and greatly improving clinical utility. Longitudinal scanning over a field of view of more than 400 µm at a frame rate of 40 Hz was accomplished with a driveshaft transduced by a piezo-electric stack motor. We present characterization and imaging results from the flexible micro-OCT probe and progress towards clinical translation. The ability of the bronchoscope-compatible micro-OCT probe to image mucus clearance and epithelial function will enable studies of cystic fibrosis pathogenesis in small airways, provide diagnosis of mucociliary clearance disorders, and allow

  1. The shock tube as wave reactor for kinetic studies and material systems

    Energy Technology Data Exchange (ETDEWEB)

    Bhaskaran, K.A. [Indian Institute of Technology, Chennai (India). Department of Mechanical Engineering; Roth, P. [Gerhard Mercator Universitat, Duisberg (Germany). Institut fur Verbrennung und Gasdynamik

    2002-07-01

    Several important reviews of shock tube kinetics have appeared earlier, prominent among them being 'Shock Tube Technique in Chemical Kinetics' by Belford and Strehlow (Ann Rev Phys Chem 20 (1969) 247), 'Chemical Reaction of Shock Waves' by Wagner (Proceedings of the Eighth International Shock Tube Symposium (1971) 4/1), 'Shock Tube and Shock Wave Research' by Bauer and Lewis (Proceedings of the 11th International Symposium on Shock Tubes and Waves (1977) 269), 'Shock Waves in Chemistry' edited by Assa Lifshitz (Shock Waves in Chemistry, 1981) and 'Shock Tube Techniques in Chemical Kinetics' by Wing Tsang and Assa Lifshitz (Annu Rev Phys Chem 41 (1990) 559). A critical analysis of the different shock tube techniques, their limitations and suggestions to improve the accuracy of the data produced are contained in these reviews. The purpose of this article is to present the current status of kinetic research with emphasis on the diagnostic techniques. Selected studies on homogeneous and dispersed systems are presented to bring out the versatility of the shock tube technique. The use of the shock tube as high temperature wave reactor for gas phase material synthesis is also highlighted. (author)

  2. Surgeon Design Interface for Patient-Specific Concentric Tube Robots.

    Science.gov (United States)

    Morimoto, Tania K; Greer, Joseph D; Hsieh, Michael H; Okamura, Allison M

    2016-06-01

    Concentric tube robots have potential for use in a wide variety of surgical procedures due to their small size, dexterity, and ability to move in highly curved paths. Unlike most existing clinical robots, the design of these robots can be developed and manufactured on a patient- and procedure-specific basis. The design of concentric tube robots typically requires significant computation and optimization, and it remains unclear how the surgeon should be involved. We propose to use a virtual reality-based design environment for surgeons to easily and intuitively visualize and design a set of concentric tube robots for a specific patient and procedure. In this paper, we describe a novel patient-specific design process in the context of the virtual reality interface. We also show a resulting concentric tube robot design, created by a pediatric urologist to access a kidney stone in a pediatric patient.

  3. Studies on defect detectability in banded stainless steel tubes

    International Nuclear Information System (INIS)

    Shyamsunder, M.T.; Rao, B.P.C.; Babu Rao, C.; Jayakumar, T.; Kalyanasundaram, P.; Baldev Raj

    1996-01-01

    During inspection of one batch of stainless steel cladding tubes, a few of the tubes gave rise to continuous large amplitude indications throughout the length of the tube. It was observed that the presence of any defects in such tubes would be impossible to detect, due to the poor signal-to-noise ratio. Detailed investigations regarding the surface profile of the tubes were carried out using a novel technique called the projected interferometry method revealed periodic diametral variations and the same were further confirmed by cross sectional profiling. The feasibility of detecting defects in such banded tubes, using eddy current testing were carried out on tubes with artificial defects. This paper discusses the use of three different eddy current methods and their relative performances for inspection. The specific advantages of the phased array eddy current testing method in unambiguous defect detection in situations similar to the one encountered during the present investigations are also discussed. (author)

  4. Depressurisation study of a tank-tubing assemble

    International Nuclear Information System (INIS)

    Freitas, R.L.

    1975-08-01

    The depressurisation of a nuclear reactor following the rupture of the primary coolant circuit is studied, using the simple analogy of the rupture of the tubing connected to a pressurised tank. The method of characteristics has been used in this theoretical analysis. The partial differential equations of conservation of mass, momentum and energy forming a hyperbolic system and defining real characteristic directions, allow the integration of these equations to be carried out along these directions. The method allows calculations to be made of the pressure, temperature, density and fluid velocity in the reactor circuit at any time after the beginning of depressurisation. A computer code MECA I has been written to calculate all the parameters after the rupture for any point in the coolant tubing. The computers used for these calculations were the IBM 360/40 and 370/145 and the Burroughs 6700. In this preliminary study, the simplest case of a system using a perfect gas coolant has been used [pt

  5. Condenser tube buckling within tube-tubesheet joints

    International Nuclear Information System (INIS)

    Willertz, L.E.; Kalnins, A.; Updike, D.P.

    1991-01-01

    The problem of the appearance of protrusions, or bumps, in the interior of roller-expanded tubes within a tubesheet is addressed. Such bumps have been observed in condensers of power plants. A brief history of the reported occurrences of the bumps is given. The hypothesis is advanced that the mechanics of the formation of the bumps is similar to a buckling problem that has 'bifurcation at infinity'. Following this hypothesis, a two-dimensional physical model is developed, and the application of this model to study a three-dimensional bump is proposed. It is proposed in this paper that an initial deviation from the circular shape of the tube required to produce a bump. It is shown that without such a deviation the tubes cannot buckle. An experiment with short tube segments has been performed that verifies some of the features of the observed condenser tube bumps. Exactly what force produced the initial deviation for the observed bumps is still unknown. Available evidence implicates the hydro-laser jet that is used in the cleaning of tubes and tubesheets. A scenario of how a bump could have been produced by the hydro-laser jet is proposed. (author)

  6. A pore-scale study of fracture dynamics in rock using X-ray micro-CT under ambient freeze-thaw cycling.

    Science.gov (United States)

    De Kock, Tim; Boone, Marijn A; De Schryver, Thomas; Van Stappen, Jeroen; Derluyn, Hannelore; Masschaele, Bert; De Schutter, Geert; Cnudde, Veerle

    2015-03-03

    Freeze-thaw cycling stresses many environments which include porous media such as soil, rock and concrete. Climate change can expose new regions and subject others to a changing freeze-thaw frequency. Therefore, understanding and predicting the effect of freeze-thaw cycles is important in environmental science, the built environment and cultural heritage preservation. In this paper, we explore the possibilities of state-of-the-art micro-CT in studying the pore scale dynamics related to freezing and thawing. The experiments show the development of a fracture network in a porous limestone when cooling to -9.7 °C, at which an exothermal temperature peak is a proxy for ice crystallization. The dynamics of the fracture network are visualized with a time frame of 80 s. Theoretical assumptions predict that crystallization in these experiments occurs in pores of 6-20.1 nm under transient conditions. Here, the crystallization-induced stress exceeds rock strength when the local crystal fraction in the pores is 4.3%. The location of fractures is strongly related to preferential water uptake paths and rock texture, which are visually identified. Laboratory, continuous X-ray micro-CT scanning opens new perspectives for the pore-scale study of ice crystallization in porous media as well as for environmental processes related to freeze-thaw fracturing.

  7. Micro-dosing for early biokinetic studies in humans

    International Nuclear Information System (INIS)

    Stenstroem, K.; Sydoff, M.; Mattsson, S.

    2010-01-01

    Micro-dosing is a new concept in drug development that-if implemented in the pharmaceutical industry-would mean that new drugs can be tested earlier in humans than done today. The human micro-dosing concept-or 'Phase 0'-may offer improved candidate selection, reduced failure rates in the drug development line and a reduction in the use of laboratory animals in early drug development, factors which will help to speed up drug development and also reduce the costs. Micro-dosing utilises sub-pharmacological amounts of the substance to open opportunities for early studies in man. Three technologies are used for micro-dosing: accelerator mass spectrometry (AMS), positron emission tomography and liquid chromatography-tandem mass spectrometry. This paper focuses on the principle of AMS and discusses the current status of micro-dosing with AMS. (authors)

  8. Development of ultrasonic testing scanner for NPP steam generator tubes (I)

    International Nuclear Information System (INIS)

    Shin, J. I.; Huh, H.

    1998-12-01

    Testing tubes are designed and fabricated to investigate the optimum test conditions through the various experiments. The proto-type P/C-controlled automatic rotating scanner is fabricated to obtain the ultrasonic data automatically from test tubes. It was attempted to visualize the shape of defects presented inside the specimen using peak amplitude at each point. However, further research works will be needed to be applied at the plant site as a more reliable technology

  9. Performance evaluation of reactor operated zircaloy-2 pressure tubes of RAPS-1

    International Nuclear Information System (INIS)

    Chatterjee, S.; Ramadasan, E.; Balakrishnan, K.S.; Bahl, J.K.

    1992-01-01

    Detailed post irradiation examination was carried out on pressure tube sections from E-10, F-9 and F-10 locations of RAPS-1 after an in-reactor residence equivalent to 3.6 effective full power years. The F-10 pressure tube was studied in detail on sections obtained from one end to the other, whereas in the case of E-9 and F-9 pressure tubes only the end sections were examined. The studies carried out were visual examination, metallography, hydrogen i.e. H(D) analysis and mechanical testing at 300 C. Microstructural observations revealed uniform and random hydride/deuteride platelet distribution and absence of blisters or hydride segregation. The H(D) content in the F-10 pressure tube was found to vary in the range 6-12 ppm. The typical H(D) content in the three tubes was around 1 ppm. The H(D) pick-up evaluated from the observed oxide layer thickness was 8 ppm. Longitudinal tensile specimens fabricated from the F-10 pressure tube section and tested at 300 C exhibited increase in yield strength and tensile strength of 39% and 30% respectively. The residual uniform elongation was typically 1.8%. The observed changes in the tensile properties were found to be lower than those reported on unstressed specimens irradiated to similar neutron fluences. The observed hydrogen content and tensile properties obtained in F-10 pressure tube would not be detrimental under normal reactor operating conditions. (author). 10 refs., 4 figs., 2 tabs., 1 annexure

  10. Vibro-impact responses of a tube with tube--baffle interaction

    International Nuclear Information System (INIS)

    Shin, Y.S.; Sass, D.E.; Jendrzejczyk, J.A.

    1978-01-01

    The relatively small, inherent tube-to-baffle hole clearances associated with manufacturing tolerances in heat exchangers affect the vibrational characteristics and the response of the tube. Numerical studies were made to predict the vibro-impact response of a tube with tube-baffle interaction. The finite element method has been employed with a non-linear elastic contact spring-dashpot to model the effect of the relative approach between the tube and the baffle plate. The coupled equations of motion are directly integrated with a proportional system damping represented by a linear combination of mass and stiffness. Lumped mass approach with explicit time integration scheme was found to be a suitable choice for tube-baffle impacting analysis. Fourier analyses indicate that the higher mode contributions to the tube response are significant for strong tube-baffle impacting. The contact damping forces are negligible compared with the contact spring forces. The numerical analysis results are in reasonably good agreement with those of the experiments

  11. YouTube's Role in Destination Image Creation

    Directory of Open Access Journals (Sweden)

    Hrvoje Jakopović

    2015-09-01

    Full Text Available Contemporary promotion of tourist destinations represents a challenge and gives rise to many questions in a regard to numerous ways of communicating and transferring information. With concern to modern communication practices in society and due to fast-paced lifestyle, individuals are looking for information online and are making decisions based on available Internet data. Attracting tourists through traditional promotional techniques such as brochures, leaflets, printed guidebooks, fairs and festivals are unsufficient with a respect to the rising number of online users. Promotion of tourism is based on destination image which is created through direct or mediated experience and projected on the minds of individuals. It is greatly dependent on available information mostly visual. YouTube is a popular video sharing site that counts over one billion users. It gives open access to a great number of videos and therefore could have an important role in promoting tourist destinations. The website was firstly used for non-commercial purposes but today it is very attractive for advertisers. The author examines phenomena of YouTube and its potential for destination image creation. The aim of this article is to give an insight on characteristics of promotional videos used for tourism and to explore how various national and local tourist boards can use them on YouTube. The author identifies the public relations profession’s role in creation of promotional audio-visual material.

  12. Miniaturised Prandtl tube with integrated pressure sensors for micro-thruster plume characterisation

    NARCIS (Netherlands)

    Dijkstra, Marcel; Ma, Kechun; de Boer, Meint J.; Groenesteijn, Jarno; Lötters, Joost Conrad; Wiegerink, Remco J.

    2014-01-01

    A miniaturised Prandtl-tube sensor incorporating a 6 mm long 40 μm diameter microchannel with integrated pressure sensors has been realised. The sensor has been designed for the characterisation of rarefied plume flow from a MEMS-based monopropellant propulsion system for high-accuracy attitude

  13. The effect of dielectric tube diameter on the propagation velocity of ionization waves in a He atmospheric-pressure micro-plasma jet

    International Nuclear Information System (INIS)

    Talviste, Rasmus; Jõgi, Indrek; Raud, Jüri; Paris, Peeter

    2016-01-01

    The focus of this study was to investigate the effect of the dielectric tube diameter on the velocity of the ionization wave in an atmospheric pressure plasma jet in He gas flow. Plasma was ignited in quartz tubes with inner diameter in the range of 80–500 μm by 6 kHz sinusoidal voltage applied to a cylindrical electrode surrounding the quartz tube and positioned 10 mm from the tube orifice. A grounded plane was placed 2–3 cm downstream from the powered electrode to measure the plasma current. The spatial development of ionization waves was monitored by registering the optical emission along the axis of the tube. The ionization wave velocity was deduced from the temporal shift of the onset of radiation at different axial positions. The velocity of ionization wave increased by almost an order of magnitude with the tube diameter decreasing from 500 to 80 μm and was for the 80 μm microtube 1.7 · 10 5 m s −1 during the positive half-cycle and 1.45 · 10 5 m s −1 during the negative half-cycle. (paper)

  14. Boiling on a tube bundle: heat transfer, pressure drop and flow patterns

    International Nuclear Information System (INIS)

    Agostini, F.

    2008-07-01

    The complexity of the two-phase flow in a tube bundle presents important problems in the design and understanding of the physical phenomena taking place. The working conditions of an evaporator depend largely on the dynamics of the two-phase flow that in turn influence the heat exchange and the pressure drop of the system. A characterization of the flow dynamics, and possibly the identification of the flow pattern in the tube bundle, is thus expected to lead to a better understanding of the phenomena and to reveal on the mechanisms governing the tube bundle. Therefore, the present study aims at providing further insights into two-phase bundle flow through a new visualization system able to provide for the first time a view of the flow in the core of a tube bundle. In addition, the measurement of the light attenuation of a laser beam through the two-phase flow and measurement of the high frequency pressure fluctuations with a piezo-electric pressure transducer are used to characterize the flow. The design and the validation of this new instrumentation also provided a method for the detection of dry-out in tube bundles. This was achieved by a laser attenuation technique, flow visualization, and estimation of the power spectrum of the pressure fluctuation. The current investigation includes results for two different refrigerants, R134a and R236fa, three saturations temperatures T sat = 5, 10 and 15 °C, mass velocities ranging from 4 to 40 kg/sm² in adiabatic and diabatic conditions (several heat fluxes). Measurement of the local heat transfer coefficient and two-phase frictional pressure drop were obtained and utilized to improve the current prediction methods. The heat transfer and pressure drop data were supported by extensive characterization of the two-phase flow, which was to improve the understanding of the two-phase flow occurring in tube bundles. (author)

  15. Preliminary Study of Fermented Tapioca for Synthesis of Carbon Nano tubes

    International Nuclear Information System (INIS)

    Nurulhuda Ismail; Ying, P.Y.

    2011-01-01

    Carbon nano tubes had been produced by various precursor such as gas (methane, carbon dioxide), oil (camphor oil, olive oil, and cooking oil) and alcohol. Different methods used for carbon nano tubes synthesis like arc discharge method, laser ablation method and chemical vapour deposition method. In this experiment, thermal chemical vapour deposition method was selected for carbon nano tubes synthesis. Starting material of fermented tapioca was used as carbon source for the process. Argon gas flow were controlled at around 10-15 bubbles per minute and deposition time around 20 to 30 minute. Others parameters such as temperature of furnace 1 and 2, amount of inoculum and catalyst have been studied. The asThermogravimetri (TGA) was used to determine the volatile temperature of the mixing catalyst and fermented tapioca extract. The grown carbon nano tubes morphology was characterized through Raman spectroscopy, scanning and Field Emission Scanning Electron Microscopy (FESEM) techniques. The surface morphology and uniformity of carbon nano tubes are reliant to parameters used. (author)

  16. MicroXRF tomographic visualization of zinc and iron in the zebrafish embryo at the onset of the hatching period

    Energy Technology Data Exchange (ETDEWEB)

    Bourassa, Daisy; Gleber, Sophie-Charlotte; Vogt, Stefan; Shin, Chong Hyun; Fahrni, Christoph J.

    2016-01-01

    Transition metals such as zinc, copper, and iron play key roles in cellular proliferation, cell differentiation, growth, and development. Over the past decade, advances in synchrotron X-ray fluorescence instrumentation presented new opportunities for the three-dimensional mapping of trace metal distributions within intact specimens. Taking advantage of microXRF tomography, we visualized the 3D distribution of zinc and iron in a zebrafish embryo at the onset of the hatching period. The reconstructed volumetric data revealed distinct differences in the elemental distributions, with zinc predominantly localized to the yolk and yolk extension, and iron to various regions of the brain as well as the myotome extending along the dorsal side of the embryo. The data set complements an earlier tomographic study of an embryo at the pharyngula stage (24 hpf), thus offering new insights into the trace metal distribution at key stages of embryonic development.

  17. Effects of tube potential and scatter rejection on image quality and effective dose in digital chest X-ray examination: An anthropomorphic phantom study

    International Nuclear Information System (INIS)

    Shaw, D.J.; Crawshaw, I.; Rimmer, S.D.

    2013-01-01

    Objectives: The purpose of this study was to investigate the effects of tube potential and scatter rejection techniques on image quality of digital posteroanterior (PA) chest radiographs. Methods: An anthropomorphic phantom was imaged using a range of tube potentials (81–125 kV p ) without scatter rejection, with an anti-scatter grid, and using a 10 cm air gap. Images were anonymised and randomised before being evaluated using a visual graded analysis (VGA) method. Results: The effects of tube potential on image quality were found to be negligible (p > 0.63) for the flat panel detector (FPD). Decreased image quality (p = 0.031) was noted for 125 kV p relative to 109 kV p , though no difference was noted for any of the other potentials (p > 0.398) for computed radiography (CR). Both scatter rejection techniques improved image quality (p p . Scatter rejection improved image quality, but with no difference found between techniques. The air-gap resulted in a smaller increase in effective dose than the anti-scatter grid and would be the preferred scatter rejection technique

  18. Effect of reciprocating systems and working lengths on apical microcrack development: a micro-CT Study

    International Nuclear Information System (INIS)

    Oliveira, Bruna Paloma de; Câmara, Andréa Cruz; Duarte, Daniel Amancio; Antonino, Antonio Celso Dantas; Aguiar, Carlos Menezes; Heck, Richard John

    2017-01-01

    The objective of this study was to evaluate the effect of root canal preparation with single-file reciprocating systems at different working lengths on the development of apical microcracks using micro-computed tomographic (micro-CT) imaging. Forty extracted human mandibular incisors were randomly assigned to 4 groups (n=10) according to the systems and working length used to prepare the root canals: Group A - WaveOne Gold at apical foramen (AF), Group B - WaveOne Gold 1 mm short of the AF (AF-1 mm), Group C - Unicone (AF) and Group D - Unicone (AF-1 mm). Micro-CT scanning was performed before and after root canal preparation at an isotropic resolution of 14 μm. Then, three examiners assessed the cross-sectional images generated to detect microcracks in the apical portion of the roots. Apical microcracks were visualized in 3, 1, 1, and 3 specimens in groups A, B, C, and D, respectively. All these microcracks observed after root canal preparation already existed prior to instrumentation, and no new apical microcrack was detected. For all groups, the number of slices presenting microcracks after root canal preparation was the same as before canal preparation. Root canal preparation with WaveOne Gold and Unicone, regardless of the working length, was not associated with apical microcrack formation. (author)

  19. Effect of reciprocating systems and working lengths on apical microcrack development: a micro-CT Study

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Bruna Paloma de; Câmara, Andréa Cruz; Duarte, Daniel Amancio; Antonino, Antonio Celso Dantas; Aguiar, Carlos Menezes, E-mail: bruna_paloma@msn.com [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil); Heck, Richard John [Department of Land Resource Science, University of Guelph (Canada)

    2017-11-15

    The objective of this study was to evaluate the effect of root canal preparation with single-file reciprocating systems at different working lengths on the development of apical microcracks using micro-computed tomographic (micro-CT) imaging. Forty extracted human mandibular incisors were randomly assigned to 4 groups (n=10) according to the systems and working length used to prepare the root canals: Group A - WaveOne Gold at apical foramen (AF), Group B - WaveOne Gold 1 mm short of the AF (AF-1 mm), Group C - Unicone (AF) and Group D - Unicone (AF-1 mm). Micro-CT scanning was performed before and after root canal preparation at an isotropic resolution of 14 μm. Then, three examiners assessed the cross-sectional images generated to detect microcracks in the apical portion of the roots. Apical microcracks were visualized in 3, 1, 1, and 3 specimens in groups A, B, C, and D, respectively. All these microcracks observed after root canal preparation already existed prior to instrumentation, and no new apical microcrack was detected. For all groups, the number of slices presenting microcracks after root canal preparation was the same as before canal preparation. Root canal preparation with WaveOne Gold and Unicone, regardless of the working length, was not associated with apical microcrack formation. (author)

  20. Contribution at the vibrations study of tube bundles in a transversal flow

    International Nuclear Information System (INIS)

    Antunes, J.

    1986-03-01

    The steam generators tubes bundles attended vibratory risks under flow. In this work we present the experimental and theoretical analysis which shows the necessary to approach this problem with taking into account the non-linear dynamic interaction between tubes and supports. An entirety of experiences put in clearness the importance of little clearance between the tubes and their supports. Methods for numerical simulation of the tubes vibratory response are proposed. Parametric analysis are presented, which permit to find simple laws concerning the influence of system parameters on its vibratory behaviour. This work is completed by analytical study of two unstable oscillators [fr

  1. Study on Boiling Heat Transfer Phenomenon in Micro-channels

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Namgyun [Inha Technical College, Incheon (Korea, Republic of)

    2017-09-15

    Recently, efficient heat dissipation has become necessary because of the miniaturization of devices, and research on boiling on micro-channels has attracted attention. However, in the case of micro-channels, the friction coefficient and heat transfer characteristics are different from those in macro-channels. This leads to large errors in the micro scale results, when compared to correlations derived from the macro scale. In addition, due to the complexity of the mechanism, the boiling phenomenon in micro-channels cannot be approached only by experimental and theoretical methods. Therefore, numerical methods should be utilized as well, to supplement these methods. However, most numerical studies have been conducted on macro-channels. In this study, we applied the lattice Boltzmann method, proposed as an alternative numerical tool to simulate the boiling phenomenon in the micro-channel, and predicted the bubble growth process in the channel.

  2. Some aspects of metallurgical assessment of boiler tubes-Basic principles and case studies

    International Nuclear Information System (INIS)

    Chaudhuri, Satyabrata

    2006-01-01

    Microstructural changes in boiler tubes during prolong operation at high temperature and pressure decrease load bearing capacity limiting their useful lives. When the load bearing capacity falls below a critical level depending on operating parameters and tube geometry, failure occurs. In order to avoid such failures mainly from the view point of economy and safety, this paper describes some basic principles behind remaining life assessment of service exposed components and also a few case studies related to failure of a reheater tube of 1.25Cr-0.5Mo steel, a carbon steel tube and final superheater tubes of 2.25Cr-1Mo steel and remaining creep life assessment of service exposed but unfailed platen superheater and reheater tubes of 2.25Cr-1Mo steel. Sticking of fly ash particles causing reduction in effective tube wall thickness is responsible for failure of reheater tubes. Decarburised metal containing intergranular cracks at the inner surface of the carbon steel tube exhibiting a brittle window fracture is an indicative of hydrogen embrittlement responsible for this failure. In contrast, final superheater tube showed that the failure took place due to short-term overheating. The influence of prolong service revealed that unfailed reheater tubes exhibit higher tensile properties than that of platen superheater tubes. In contrast both the tubes at 50 MPa meet the minimum creep rupture properties when compared with NRIM data. The remaining creep life of platen superheater tube as estimated at 50 MPa and 570 deg. C (1058 o F) is more than 10 years and that of reheater tube at 50 MPa and 580 deg. C (1076 o F) is 9 years

  3. How data-ink maximization can motivate learners – Persuasion in data visualization

    OpenAIRE

    Gottschalk, Judith

    2017-01-01

    This paper discusses both the macro- and the micro-level of persuasion in data visualizations in persuasive tools for language learning. The hypothesis of this paper is that persuasive data visualizations decrease reading time and increase reading accuracy of graph charts. Based on Tufte’s (1983) data-ink maximization principle the report introduces a framework for persuasive data visualizations on the persuasive micro level which employs Few’s (2013) conception of de-emphasizing non-data and...

  4. AC dielectrophoresis alignment of single-walled carbon nano tubes (SWNTS) and palladium nano wires for hydrogen gas sensor

    International Nuclear Information System (INIS)

    Nur Ubaidah Saidin; Nur Ubaidah Saidin; Ying, K.K.; KKhuan, N.I.; Mohammad Hafizuddin Jumali

    2013-01-01

    Full-text: Using AC electric field, nano wires or nano tubes can be aligned, chained or accelerated in a direction parallel to the applied field, oriented or concentrated onto designated locations as well as dispersed in controlled manner under high efficiencies. In this work, systematic study on the alignment of nano wires/ nano tubes across the 3 μm-gaps between pairs of micro fabricated gold electrodes was carried out using AC dielectrophoresis technique. Densities and alignment of the nano wires/ nano tubes across the gaps of the electrodes were controlled by the applied AC field strengths and frequencies on the electrodes. Good alignments of SWNTs and Pd nano wires were achieved at an applied frequency of 5 MHz and a field strength as high as 25 V pp for Pd nano wires compared to only 2 V pp for SWNTs. The aligned nano wires/ nano tubes will be functioned as sensor elements for hydrogen gas sensing. (author)

  5. Coronary artery wall imaging in mice using osmium tetroxide and micro-computed tomography (micro-CT)

    International Nuclear Information System (INIS)

    Pai, Vinay M.; Kozlowski, Megan; Donahue, Danielle; Miller, Elishiah; Xiao, Xianghui; Chen, Marcus Y.; Yu, Zu-Xi; Connelly, Patricia; Jeffries, Kenneth; Wen, Han

    2012-01-01

    The high spatial resolution of micro-computed tomography (micro-CT) is ideal for 3D imaging of coronary arteries in intact mouse heart specimens. Previously, micro-CT of mouse heart specimens utilized intravascular contrast agents that hardened within the vessel lumen and allowed a vascular cast to be made. However, for mouse coronary artery disease models, it is highly desirable to image coronary artery walls and highlight plaques. For this purpose, we describe an ex vivo contrast-enhanced micro-CT imaging technique based on tissue staining with osmium tetroxide (OsO 4 ) solution. As a tissue-staining contrast agent, OsO 4 is retained in the vessel wall and surrounding tissue during the fixation process and cleared from the vessel lumens. Its high X-ray attenuation makes the artery wall visible in CT. Additionally, since OsO 4 preferentially binds to lipids, it highlights lipid deposition in the artery wall. We performed micro-CT of heart specimens of 5- to 25-week-old C57BL/6 wild-type mice and 5- to 13-week-old apolipoprotein E knockout (apoE -/- ) mice at 10 μm resolution. The results show that walls of coronary arteries as small as 45 μm in diameter are visible using a table-top micro-CT scanner. Similar image clarity was achieved with 1/2000th the scan time using a synchrotron CT scanner. In 13-week-old apoE mice, lipid-rich plaques are visible in the aorta. Our study shows that the combination of OsO 4 and micro-CT permits the visualization of the coronary artery wall in intact mouse hearts.

  6. Observation of "YouTube" Language Learning Videos ("YouTube" LLVS)

    Science.gov (United States)

    Alhamami, Munassir

    2013-01-01

    This paper navigates into the "YouTube" website as one of the most usable online tools to learn languages these days. The paper focuses on two issues in creating "YouTube" language learning videos: pedagogy and technology. After observing the existing "YouTube" LLVs, the study presents a novel rubric that is directed…

  7. Intubation simulation with a cross-sectional visual guidance.

    Science.gov (United States)

    Rhee, Chi-Hyoung; Kang, Chul Won; Lee, Chang Ha

    2013-01-01

    We present an intubation simulation with deformable objects and a cross-sectional visual guidance using a general haptic device. Our method deforms the tube model when it collides with the human model. Mass-Spring model with the Euler integration is used for the tube deformation. For the trainee's more effective understanding of the intubation process, we provide a cross-sectional view of the oral cavity and the tube. Our system also applies a stereoscopic rendering to improve the depth perception and the reality of the simulation.

  8. Experimental study for transient response of a double-tube thermosyphon (DTTH)

    International Nuclear Information System (INIS)

    Salem, M.A.M.

    2010-01-01

    Energy conservation is becoming increasingly important as the cost of fuel continuously rises. The heat pipe and the closed two-phase thermosyphon are particularly effective tools in the heat transfer process.A theoretical and experimental investigation was conducted to study the double-tube two-phase closed-thermosyphon (DTTH) behavior in transient regimes. Experiments were performed to investigate the effects of changing the heating and cooling rate as well as the evaporator length on the double tube thermosyphon in actual integrated operation (start-up, steady-state and shut-down). he necessity for a dynamic model of DTTH for some applications of discontinuous operation imposed the need to the current applied investigation. Therefore, the main objective of the current study is to develop a theoretical model that can predict the dynamic behavior of the double-tube evaporator by tracing various transient parameters during operation from start up to steady state until shut down condition. A model describing both thermal and phase flows of the closed two-phase double tube thermosyphon (DTTH) has been simulated. The theoretical model provides a general description of the behavior of our practical setup based on experimental observations which show a simple exponential behavior. It is based on a two thermal body description (evaporator wall and working fluid) there is good agreement between experiments data and numerical prediction.A computer simulation program based on the method was developed to estimate temperature and the other performance of double tube thermosyphon as well as the time needed to reach steady state condition. The governing equations of the simple 1-D model were solved by Engineering Equation Solver program (EES) using finite difference Euler method. A computer program is designed to solve these differential equations by an explicit finite difference method. The results from this model were found to be in general agreement with the experimental

  9. Numerical and Experimental Study on a Model Draft Tube with Vortex Generators

    Directory of Open Access Journals (Sweden)

    Tian Xiaoqing

    2013-01-01

    Full Text Available A model water turbine draft tube containing vortex generators (VG was studied. Numerical simulations were performed to investigate 55 design variations of the vortex generators in a draft tube. After analyzing the shapes of streamlines and velocity distributions in the tube and comparing static pressure recovery coefficients (SPRC in different design variations, an optimum vortex generator layout, which can raise SPRC of the draft tube by 4.8 percent, was found. To verify the effectiveness of the vortex generator application, a series of experiments were carried out. The results show that by choosing optimal vortex generator parameters, such as the installation type, installation position, blade-to-blade distance, and blade inclination angle, the draft tube equipped vortex generators can effectively raise their SPRC andworking stability.

  10. THE TOPOLOGY OF CANONICAL FLUX TUBES IN FLARED JET GEOMETRY

    Energy Technology Data Exchange (ETDEWEB)

    Lavine, Eric Sander; You, Setthivoine, E-mail: Slavine2@uw.edu, E-mail: syou@aa.washington.edu [University of Washington, 4000 15th Street, NE Aeronautics and Astronautics 211 Guggenheim Hall, Box 352400, Seattle, WA 98195 (United States)

    2017-01-20

    Magnetized plasma jets are generally modeled as magnetic flux tubes filled with flowing plasma governed by magnetohydrodynamics (MHD). We outline here a more fundamental approach based on flux tubes of canonical vorticity, where canonical vorticity is defined as the circulation of the species’ canonical momentum. This approach extends the concept of magnetic flux tube evolution to include the effects of finite particle momentum and enables visualization of the topology of plasma jets in regimes beyond MHD. A flared, current-carrying magnetic flux tube in an ion-electron plasma with finite ion momentum is thus equivalent to either a pair of electron and ion flow flux tubes, a pair of electron and ion canonical momentum flux tubes, or a pair of electron and ion canonical vorticity flux tubes. We examine the morphology of all these flux tubes for increasing electrical currents, different radial current profiles, different electron Mach numbers, and a fixed, flared, axisymmetric magnetic geometry. Calculations of gauge-invariant relative canonical helicities track the evolution of magnetic, cross, and kinetic helicities in the system, and show that ion flow fields can unwind to compensate for an increasing magnetic twist. The results demonstrate that including a species’ finite momentum can result in a very long collimated canonical vorticity flux tube even if the magnetic flux tube is flared. With finite momentum, particle density gradients must be normal to canonical vorticities, not to magnetic fields, so observations of collimated astrophysical jets could be images of canonical vorticity flux tubes instead of magnetic flux tubes.

  11. High resolution micro-CT scanning as an innovative tool for evaluation of the surgical positioning of cochlear implant electrodes.

    Science.gov (United States)

    Postnov, A; Zarowski, A; De Clerck, N; Vanpoucke, F; Offeciers, F E; Van Dyck, D; Peeters, S

    2006-05-01

    X-ray microtomography (micro-CT) is a new technique allowing for visualization of the internal structure of opaque specimens with a quasi-histological quality. Among multiple potential applications, the use of this technique in otology is very promising. Micro-CT appears to be ideally suited for in vitro visualization of the inner ear tissues as well as for evaluation of the electrode damage and/or surgical insertion trauma during implantation of the cochlear implant electrodes. This technique can greatly aid in design and development of new cochlear implant electrodes and is applicable for temporal bone studies. The main advantage of micro-CT is the practically artefact-free preparation of the samples and the possibility of evaluation of the interesting parameters along the whole insertion depth of the electrode. This paper presents the results of the first application of micro-CT for visualization of the inner ear structures in human temporal bones and for evaluation of the surgical positioning of the cochlear implant electrodes relative to the intracochlear soft tissues.

  12. Visually guided male urinary catheterization: a feasibility study.

    Science.gov (United States)

    Willette, Paul A; Banks, Kevin; Shaffer, Lynn

    2013-01-01

    Ten percent to 15% of urinary catheterizations involve complications. New techniques to reduce risks and pain are indicated. This study examines the feasibility and safety of male urinary catheterization by nursing personnel using a visually guided device in a clinical setting. The device, a 0.6-mm fiber-optic bundle inside a 14F triple-lumen flexible urinary catheter with a lubricious coating, irrigation port, and angled tip, connects to a camera, allowing real-time viewing of progress on a color monitor. Two emergency nurses were trained to use the device. Male patients 18 years or older presenting to the emergency department with an indication for urinary catheterization using a standard Foley or Coudé catheter were eligible to participate in the study. Exclusion criteria were a current suprapubic tube or gross hematuria prior to the procedure. Twenty-five patients were enrolled. Data collected included success of placement, total procedure time, pre-procedure pain and maximum pain during the procedure, gross hematuria, abnormalities or injuries identified if catheterization failed, occurrence of and reason for equipment failures, and number of passes required for placement. All catheters were successfully placed. The median number of passes required was 1. For all but one patient, procedure time was ≤ 17 minutes. A median increase in pain scores of 1 point from baseline to the maximum was reported. Gross hematuria was observed in 2 patients. The success rate for placement of a Foley catheter with the visually guided device was 100%, indicating its safety, accuracy, and feasibility in a clinical setting. Minimal pain was associated with the procedure. Copyright © 2013 Emergency Nurses Association. Published by Mosby, Inc. All rights reserved.

  13. Vaporization inside a mini microfin tube: experimental results and modeling

    Science.gov (United States)

    Diani, A.; Rossetto, L.

    2015-11-01

    This paper proposes a comparison among the common R134a and the extremely low GWP refrigerant R1234yf during vaporization inside a mini microfin tube. This microfin tube has an internal diameter of 2.4 mm, it has 40 fins, with a fin height of 0.12 mm. Due to the high heat transfer coefficients shown by this tube, this technology can lead to a refrigerant charge reduction. Tests were run in the Heat Transfer in Micro Geometries Lab of the Dipartimento di Ingegneria Industriale of the Università di Padova. Mass velocities range between 375 and 940 kg m-2 s-1, heat fluxes from 10 to 50 kW m-2, vapour qualities from 0.10 to 0.99, at a saturation temperature of 30°C. The comparison among the two fluids is proposed at the same operating conditions, in order to highlight the heat transfer and pressure drop differences among the two refrigerants. In addition, two correlations are proposed to estimate the heat transfer coefficient and frictional pressure drop during refrigerant flow boiling inside mini microfin tubes. These correlations well predict the experimental values, and thus they can be used as a useful tool to design evaporators based on these mini microfin tubes.

  14. Nondestructive Analysis of Apollo Samples by Micro-CT and Micro-XRF Analysis: A PET Style Examination

    Science.gov (United States)

    Zeigler, Ryan A.

    2014-01-01

    An integral part of any sample return mission is the initial description and classification of returned samples by the preliminary examination team (PET). The goal of a PET is to characterize and classify the returned samples, making this information available to the general research community who can then conduct more in-depth studies on the samples. A PET strives to minimize the impact their work has on the sample suite, which often limits the PET work to largely visual measurements and observations like optical microscopy. More modern techniques can also be utilized by future PET to nondestructively characterize astromaterials in a more rigorous way. Here we present our recent analyses of Apollo samples 14321 and 14305 by micro-CT and micro-XRF (respectively), assess the potential for discovery of "new" Apollo samples for scientific study, and evaluate the usefulness of these techniques in future PET efforts.

  15. Switching process between bistable positons of multiquantum flux tubes in a thin-film type I superconductor

    International Nuclear Information System (INIS)

    Parisi, J.; Huebener, R.P.; Muhlemeier, B.

    1983-01-01

    A superconducting memory device based on a bistable vortex position represents an interesting storage medium for future Josephson computers. In order to study the operational mode of such a single-flux quantum memory cell, we use as a model system multiquantum flux tubes in a thin-film type I superconductor (Pb). By employing high-resolution stroboscopic magnetooptical flux detection, we are able to globally visualize both spatial and temporal behavior of rapidly switching individual flux tubes. All experimental results agree reasonably well with theoretical model considerations of the energy balance during the elementary switching process

  16. LIBS, LA-ICPMS and synchrotron hard x-ray micro-radiography and micro-tomography complementary study of elemental distributions in biominerals

    International Nuclear Information System (INIS)

    Kaiser, J.; Novotny, K.; Hola, M.; Kanicky, V.; Martinec, P.; Hahn, D.W.; Diwakar, P.K.; Mancini, L.; Tromba, G.; Sodini, N.

    2009-01-01

    Full text: Analysis of bio-minerals can provide information about the chronology, diet and palaeoenvironment of past populations. More specifically, e.g. line scans of uroliths cross-sections may be used to detect the accumulation history of the selected elements. This can be linked to the patients' exposure to environmental effects. Together with the main components, biogenous and toxic trace elements can be monitored. We report on utilization of two laser-ablation based analytical techniques for mapping elemental distribution in bio-minerals, coupled to hard x-ray microradiography and micro-CT measurements for visualization of the inner structure of the investigated samples. (author)

  17. Model study of DC ignition of fluorescent tubes

    International Nuclear Information System (INIS)

    Brok, W J M; Gendre, M F; Mullen, J J A M van der

    2007-01-01

    Breakdown in a discharge tube is investigated by means of a fluid model. The discharge tube is similar to a compact fluorescent lamp tube, containing argon at 3 Torr and mercury at a few millitorr. It was found that the minimum breakdown voltage is decreased substantially compared with a tube containing pure argon. Penning ionization of mercury via an argon metastable state plays an important role in this effect. This is illustrated for a lamp operated on a DC voltage, where significant Penning ionization takes place in the wake of the ionization front. Furthermore, contrary to what is suggested in earlier literature, the development of the surface potential of the lamp is shown to be not only determined by surface charges, but also by volume charges

  18. Ultra-Precise Assembly of Micro-Electromechanical Systems (MEMS) Components

    Energy Technology Data Exchange (ETDEWEB)

    Feddema, J.T.; Simon, R.; Polosky, M.; Christenson, T.

    1999-04-01

    This report summarizes a three year effort to develop an automated microassembly workcell for the assembly of LIGA (Lithography Galvonoforming Abforming) parts. Over the last several years, Sandia has developed processes for producing surface machined silicon and LIGA parts for use in weapons surety devices. Some of these parts have outside dimensions as small as 100 micron, and most all have submicron tolerances. Parts this small and precise are extremely difficult to assembly by hand. Therefore, in this project, we investigated the technologies required to develop a robotic workcell to assembly these parts. In particular, we concentrated on micro-grippers, visual servoing, micro-assembly planning, and parallel assembly. Three different micro-grippers were tested: a pneumatic probe, a thermally actuated polysilicon tweezer, and a LIGA fabricated tweezer. Visual servoing was used to accuracy position two parts relative to one another. Fourier optics methods were used to generate synthetic microscope images from CAD drawings. These synthetic images are used off-line to test image processing routines under varying magnifications and depths of field. They also provide reference image features which are used to visually servo the part to the desired position. We also investigated a new aspect of fine motion planning for the micro-domain. As parts approach 1-10 {micro}m or less in outside dimensions, interactive forces such as van der Waals and electrostatic forces become major factors which greatly change the assembly sequence and path plans. We developed the mathematics required to determine the goal regions for pick up, holding, and release of a micro-sphere being handled by a rectangular tool. Finally, we implemented and tested the ability to assemble an array of LIGA parts attached to two 3 inch diameter wafers. In this way, hundreds of parts can be assembled in parallel rather than assembling each part individually.

  19. Which mode and potency of electrocoagulation yields the Smallest Unobstructed Area of the Fallopian Tubes?

    Science.gov (United States)

    Campagnolo, Marcelo Ivo; Reis, Ricardo Dos; Santos, Marcele Oliveira Dos; Kliemann, Lúcia Maria; Savaris, Ricardo Francalacci

    2018-05-29

     To determine which mode and potency of electrocoagulation, using a modern electrosurgical generator, yields the smallest unobstructed area of the Fallopian tubes.  In an experimental study, tubes from 48 hysterectomies or tubal ligation were evaluated. Tubes were randomly allocated to one of the following groups: group A) 25 W x 5 seconds ( n  = 17); group B) 30 W x 5 seconds ( n  = 17); group C) 35 W x 5 seconds ( n  = 18), group D) 40 W x 5 seconds ( n  = 20); group E) 40 W x 5 seconds with visual inspection (blanch, swells, collapse) ( n  = 16); group F) 50 W x 5 seconds ( n  = 8). Bipolar electrocoagulation was performed in groups A to E, and monopolar electrocoagulation was performed in group F. Coagulation mode was used in all groups. Digital photomicrography of the transversal histological sections of the isthmic segment of the Fallopian tube were taken, and the median percentage of unobstructed luminal area (mm 2 ) was measured with ImageJ software (ImageJ, National Institutes of Health, Bethesda, MD, USA). The Kruskal-Wallis test or analysis of variance (ANOVA) was used for statistical analysis.  Ninety-six Fallopian tube sections were analyzed. The smallest median occluded area (%; range) of the Fallopian tube was obtained in the group with 40 W with visual inspection (8.3%; 0.9-40%), followed by the groups 25 W (9.1%; 0-35.9%), 40 W (14.2; 0.9-43.2%), 30 W (14.2; 0.9-49.7%), 35 W (15.1; 3-46.4%) and 50 W (38.2; 3.1-51%). No statistically significant difference was found among groups ( p  = 0.09, Kruskal-Wallis test).  The smallest unobstructed area was obtained with power setting at 40 W with visual inspection using a modern electrosurgical generator. However, no statistically significant difference in the unobstructed area was observed among the groups using these different modes and potencies. Thieme Revinter Publicações Ltda Rio de Janeiro, Brazil.

  20. A study on the leak monitoring of boiler tube in power plants

    International Nuclear Information System (INIS)

    Lee, Sang Guk

    2002-01-01

    Main equipment of thermal power plant, such as boiler and turbine, are designed and manufactured by domestic techniques. But the special equipments monitoring the operation status of these main facilities are still dependent upon foreign technology. Therefore, so as to develop boiler tube leak detection system, we performed studying on manufacturing, installation in site, Acoustic Emission (AE) signal analysis and discrimination etc. As result of studying on boiler tube leak detection using AE, we conformed that diagnosis for boiler tube and computerized their trend management is possible, and also it is expected to contribute to safe operation of power plant facilities

  1. Image Reconstruction and Evaluation: Applications on Micro-Surfaces and Lenna Image Representation

    Directory of Open Access Journals (Sweden)

    Mohammad Mayyas

    2016-09-01

    Full Text Available This article develops algorithms for the characterization and the visualization of micro-scale features using a small number of sample points, with the goal of mitigating the measurement shortcomings, which are often destructive or time consuming. The popular measurement techniques that are used in imaging of micro-surfaces include the 3D stylus or interferometric profilometry and Scanning Electron Microscopy (SEM, where both could represent the micro-surface characteristics in terms of 3D dimensional topology and greyscale image, respectively. Such images could be highly dense; therefore, traditional image processing techniques might be computationally expensive. We implement the algorithms in several case studies to rapidly examine the microscopic features of micro-surface of Microelectromechanical System (MEMS, and then we validate the results using a popular greyscale image; i.e., “Lenna” image. The contributions of this research include: First, development of local and global algorithm based on modified Thin Plate Spline (TPS model to reconstruct high resolution images of the micro-surface’s topography, and its derivatives using low resolution images. Second, development of a bending energy algorithm from our modified TPS model for filtering out image defects. Finally, development of a computationally efficient technique, referred to as Windowing, which combines TPS and Linear Sequential Estimation (LSE methods, to enhance the visualization of images. The Windowing technique allows rapid image reconstruction based on the reduction of inverse problem.

  2. Study on thermal and mechanical properties of U-tube materials for steam generator

    International Nuclear Information System (INIS)

    Rheu, Woo Suk; Kang, Young Hwan; Park, Jong Man; Joo, Ki Nam; Kim, Sung Soo; Maeng, Wan Young; Park, Se Jin

    1993-01-01

    Most of domestic nuclear plants have used I600 TT material for steam generator U-tube, and piled up the field experience. I600 HTMA and I690 TT, however, are recommended for an alternative of U-tube by ABB-CE since YK-3 and 4. Field experience of I600 HTMA and I690 TT have not compiled in the country, so it is concerned to select the future materials for U-tube. Thus, database on the thermal and mechanical properties of U-tube materials is very necessary for design documentations. In this study, the thermal, mechanical and metallugical properties were tested and evaluated to establish the database for steam generator U-tube. In addition, thermal conductivity of I600 and I690 was measured and compared statistically, providing a basic document for applying I690 to U-tube. The results will be used to improve the manufacturing process in order to increase the integrity of U-tube. (Author)

  3. Use of Micro-Computed Tomography for Dental Studies in Modern and Fossil Odontocetes: Potential Applications and Limitations

    Directory of Open Access Journals (Sweden)

    Carolina Loch

    2013-10-01

    Full Text Available Teeth are important elements in studies of modern and fossil Cetacea (whales, dolphins, providing information on feeding habits, estimations of age and phylogenetic relationships. The growth layer groups (GLGs recorded in dentine have demonstrated application for aging studies, but also have the potential to elucidate life history phenomena such as metabolic or physiologic events. Micro-Computed Tomography (Micro-CT is a non-invasive and non-destructive technique that allows 3-dimensional study of mineralized tissues, such as human teeth, and their physical properties. Teeth from extant dolphins (Cetacea: Odontoceti and some fossil odontocetes were scanned in a Skyscan 1172 Micro-CT desktop system. X-rays were generated at 100 kV and 100 µA for extant samples, and at 80kV and 124 µA for fossils. 0.5 mm thick aluminum and copper filters were used in the beam. Reconstructed images were informative for most extant species, showing a good resolution of the enamel layer, dentine and pulp cavity. Greyscale changes in the dentinal layers were not resolved enough to show GLGs. Visualization of the internal structure in fossil cetacean teeth depended on the degree of diagenetic alteration in the specimen; undifferentiated enamel and dentine regions probably reflect secondary mineralization. However, internal details were finely resolved for one fossil specimen, showing the enamel, internal layers of dentine and the pulp cavity. Micro-CT has been proven to be a useful tool for resolving the internal morphology of fossil and extant teeth of cetaceans before they are sectioned for other morphological analyses; however some methodological refinements are still necessary to allow better resolution of dentine for potential application in non-destructive age determination studies.

  4. In vivo microCT imaging of rodent cerebral vasculature

    International Nuclear Information System (INIS)

    Seo, Youngho; Hasegawa, Bruce H; Hashimoto, Tomoki; Nuki, Yoshitsugu

    2008-01-01

    Computed tomography (CT) remains a critical diagnostic tool for evaluating patients with cerebrovascular disease, and the advent of specialized systems for imaging rodents has extended these techniques to small animal models of these diseases. We therefore have evaluated in vivo methods of imaging rat models of hemorrhagic stroke using a high resolution compact computed tomography ('microCT') system (FLEX(tm) X-O(tm), Gamma Medica-Ideas, Northridge, CA). For all in vivo studies, the head of the anesthetized rat was secured in a custom immobilization device for microCT imaging with 512 projections over 2 min at 60 kVp and 0.530 mA (I tube x t/rotation = 63.6 mAs). First, imaging without iodinated contrast was performed (a) to differentiate the effect of contrast agent in contrast-enhanced CT and (b) to examine the effectiveness of the immobilization device between two time points of CT acquisitions. Then, contrast-enhanced CT was performed with continuous administration of iopromide (300 mgI ml -1 at 1.2 ml min -1 ) to visualize aneurysms and other vascular formations in the carotid and cerebral arteries that may precede subarachnoid hemorrhage. The accuracy of registration between the noncontrast and contrast-enhanced CT images with the immobilization device was compared against the images aligned with normalized mutual information using FMRIB's linear image registration tool (FLIRT). Translations and rotations were examined between the FLIRT-aligned noncontrast CT image and the nonaligned noncontrast CT image. These two data sets demonstrated translational and rotational differences of less than 0.5 voxel (∼85 μm) and 0.5 deg., respectively. Noncontrast CT demonstrated a very small volume (0.1 ml) of femoral arterial blood introduced surgically into the rodent brain. Continuous administration of iopromide during the CT acquisition produced consistent vascular contrast in the reconstructed CT images. As a result, carotid arteries and major cerebral blood vessels

  5. In vivo microCT imaging of rodent cerebral vasculature

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Youngho; Hasegawa, Bruce H [Center for Molecular and Functional Imaging, Department of Radiology, University of California, San Francisco, CA 94143 (United States); Hashimoto, Tomoki; Nuki, Yoshitsugu [Center for Cerebrovascular Research, Department of Anesthesia and Perioperative Care, University of California, San Francisco, CA 94143 (United States)], E-mail: youngho.seo@radiology.ucsf.edu

    2008-04-07

    Computed tomography (CT) remains a critical diagnostic tool for evaluating patients with cerebrovascular disease, and the advent of specialized systems for imaging rodents has extended these techniques to small animal models of these diseases. We therefore have evaluated in vivo methods of imaging rat models of hemorrhagic stroke using a high resolution compact computed tomography ('microCT') system (FLEX(tm) X-O(tm), Gamma Medica-Ideas, Northridge, CA). For all in vivo studies, the head of the anesthetized rat was secured in a custom immobilization device for microCT imaging with 512 projections over 2 min at 60 kVp and 0.530 mA (I{sub tube} x t/rotation = 63.6 mAs). First, imaging without iodinated contrast was performed (a) to differentiate the effect of contrast agent in contrast-enhanced CT and (b) to examine the effectiveness of the immobilization device between two time points of CT acquisitions. Then, contrast-enhanced CT was performed with continuous administration of iopromide (300 mgI ml{sup -1} at 1.2 ml min{sup -1}) to visualize aneurysms and other vascular formations in the carotid and cerebral arteries that may precede subarachnoid hemorrhage. The accuracy of registration between the noncontrast and contrast-enhanced CT images with the immobilization device was compared against the images aligned with normalized mutual information using FMRIB's linear image registration tool (FLIRT). Translations and rotations were examined between the FLIRT-aligned noncontrast CT image and the nonaligned noncontrast CT image. These two data sets demonstrated translational and rotational differences of less than 0.5 voxel ({approx}85 {mu}m) and 0.5 deg., respectively. Noncontrast CT demonstrated a very small volume (0.1 ml) of femoral arterial blood introduced surgically into the rodent brain. Continuous administration of iopromide during the CT acquisition produced consistent vascular contrast in the reconstructed CT images. As a result, carotid

  6. Analysis of steam generator tube sections removed from Gentilly-2 nuclear generating station

    International Nuclear Information System (INIS)

    Semmler, J.; Lockley, A.J.; Doyon, D.

    2010-01-01

    In order to meet the requirements of CSA Standards CAN/CSA N285.4-94, which states, 'A section of one tube in a deposit region shall be removed from one steam generator for metallurgical examination', Gentilly-2 has been removing steam generator tube sections on a regular basis for analysis at Chalk River Laboratories. In 2009 April, sections from the hot leg and the cold leg of a steam generator tube were removed for detailed metallographic examination and characterization. The hot leg tube section covered the area from within the tube sheet up to below the second support plate, and the cold leg tube section covered the area from within the tube sheet to below the third preheater support plate. After a general visual and photographic examination, the area above the tube sheet on the hot leg side where the sludge pile is highest was examined in detail. Visual and macro-photography of the two tube sections within the tube sheet were also examined. Additional metallographic and surface examinations of both tube inner diameter and tube outer diameter, and surface roughness measurements of tube inner diameter were also completed. The surface activities (μCi/cm 2 ) of cold leg and hot leg specimens were measured before and after electrolytic descaling, and major and minor radionuclides were identified; a comparison of the surface activities for hot leg with the values for the cold leg were made. The results from the initial γ-spectroscopy measurements, and the measurements after the descaling of the specimens were used to estimate decontamination factors for each specimen and for each radionuclide. The tube specimens had thin outer diameter oxides; all four steam generators were chemically cleaned in 2005. All specimens had inner diameter deposits; the inner diameter deposits on the cold leg were heavier than those on the hot leg as expected. Primary side oxide loadings of specimens were used to estimate the total oxide inventory in 2009. The oxide

  7. Experimental study and modelisation of a pulse tube refrigerator

    International Nuclear Information System (INIS)

    Ravex, A.; Rolland, P.; Liang, J.

    1992-01-01

    A test bench for pulse tube refrigerator characterization has been built. In various configurations (basic pulse tube, orifice pulse tube and double inlet pulse tube), the ultimate temperature and the cooling power have been measured as a function of pressure wave amplitude and frequency for various geometries. A lowest temperature of 28 K has been achieved in a single staged double inlet configuration. A modelisation taking into account wall heat pumping, enthalpy flow and regenerator inefficiency is under development. Preliminary calculation results are compared with experimental data

  8. Using a Bedside Video-assisted Test Tube Test to Assess Stoma Viability: A Report of 4 Cases.

    Science.gov (United States)

    Ahmad, Sarwat; Turner, Keli; Shah, Paulesh; Diaz, Jose

    2016-07-01

    Mucosal discoloration of an intestinal stoma may indicate self-limited venous congestion or necrosis necessitating operative revision. A common bedside technique to assess stoma viability is the "test tube test". A clear tube is inserted into the stoma and a hand-held light is used to assess the color of the stoma. A technique (video-assisted test tube test [VATTT]) developed by the authors utilizes a standard video bronchoscope inserted into a clear plastic blood collection tube to visually inspect and assess the mucosa. This technique was evaluated in 4 patients (age range 49-72 years, all critically ill) with a discolored stoma after emergency surgery. In each case, physical exam revealed ischemic mucosa at the surface either immediately after surgery or after worsening hypotension weeks later. Serial test tube test assessments were ambiguous when trying to assess deeper mucosa. The VATTT assessment showed viable pink mucosa beneath the surface and until the fascia was revealed in 3 patients. One (1) patient had mucosal ischemia down to the fascia, which prompted operative revision of the stoma. The new stoma was assessed with a VATTT and was viable for the entire length of the stoma. VATTT provided an enhanced, magnified, and clearer way to visually assess stoma viability in the postoperative period that can be performed at the bedside with no adverse events. It may prevent unnecessary relaparotomy or enable earlier diagnosis of deep ostomy necrosis. Validity and reliability studies are warranted.

  9. Experimental study on a simple Ranque-Hilsch vortex tube

    NARCIS (Netherlands)

    Gao, C.; Bosschaart, K.J.; Zeegers, J.C.H.; Waele, de A.T.A.M.

    2005-01-01

    The Ranque-Hilsch vortex tube is a device by which cold gas can be generated using compressed gas. To understand the cooling mechanism of this device, it is necessary to know the pressure, temperature, and velocity distributions inside the tube. In order to investigate this, a simple vortex tube is

  10. Vibro-impact responses of a tube with tube--baffle interaction. [LMFBR

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Y S; Sass, D E; Jendrzejczyk, J A

    1978-01-01

    The relatively small, inherent tube-to-baffle hole clearances associated with manufacturing tolerances in heat exchangers affect the vibrational characteristics and the response of the tube. Numerical studies were made to predict the vibro-impact response of a tube with tube-baffle interaction. The finite element method has been employed with a non-linear elastic contact spring-dashpot to model the effect of the relative approach between the tube and the baffle plate. The coupled equations of motion are directly integrated with a proportional system damping represented by a linear combination of mass and stiffness. Lumped mass approach with explicit time integration scheme was found to be a suitable choice for tube-baffle impacting analysis. Fourier analyses indicate that the higher mode contributions to the tube response are significant for strong tube-baffle impacting. The contact damping forces are negligible compared with the contact spring forces. The numerical analysis results are in reasonably good agreement with those of the experiments.

  11. The role of background music in the experience of watching YouTube videos about death and dying

    Directory of Open Access Journals (Sweden)

    Panagiotis Pentaris

    2015-12-01

    Full Text Available YouTube is the largest video sharing site live at the moment. It has been used to communicate a vast array of information, while it allows for user-generated content. This paper will focus on YouTube videos that communicate death, and in particular will present findings from a preliminary study undertaken by the authors considering the role that background music plays in these videos. Specifically, this study explores the experiences of the viewers of death-related YouTube videos with and without background music while it makes comparisons in relation to the impact that music has on the viewers’ emotional experiences. We conclude that background music elicits emotions and enhances feelings of sadness and sympathy in relation to the visual content of videos while recommendations for future research are made.

  12. The effect of two different visual presentation modalities on the narratives of mainstream grade 3 children.

    Science.gov (United States)

    Klop, D; Engelbrecht, L

    2013-12-01

    This study investigated whether a dynamic visual presentation method (a soundless animated video presentation) would elicit better narratives than a static visual presentation method (a wordless picture book). Twenty mainstream grade 3 children were randomly assigned to two groups and assessed with one of the visual presentation methods. Narrative performance was measured in terms of micro- and macrostructure variables. Microstructure variables included productivity (total number of words, total number of T-units), syntactic complexity (mean length of T-unit) and lexical diversity measures (number of different words). Macrostructure variables included episodic structure in terms of goal-attempt-outcome (GAO) sequences. Both visual presentation modalities elicited narratives of similar quantity and quality in terms of the micro- and macrostructure variables that were investigated. Animation of picture stimuli did not elicit better narratives than static picture stimuli.

  13. Study of low vibration 4 K pulse tube cryocoolers

    Science.gov (United States)

    Xu, Mingyao; Nakano, Kyosuke; Saito, Motokazu; Takayama, Hirokazu; Tsuchiya, Akihiro; Maruyama, Hiroki

    2012-06-01

    Sumitomo Heavy Industries, Ltd. (SHI) has been continuously improving the efficiency and reducing the vibration of a 4 K pulse tube cryocooler. One advantage of a pulse tube cryocooler over a GM cryocooler is low vibration. In order to reduce vibration, both the displacement and the acceleration have to be reduced. The vibration acceleration can be reduced by splitting the valve unit from the cold head. One simple way to reduce vibration displacement is to increase the wall thickness of the tubes on the cylinder. However, heat conduction loss increases while the wall thickness increases. To overcome this dilemma, a novel concept, a tube with non-uniform wall thickness, is proposed. Theoretical analysis of this concept, and the measured vibration results of an SHI lowvibration pulse tube cryocooler, will be introduced in this paper.

  14. Study tube housing leakage of 111 conventional diagnostic X-ray machines using ion chamber survey meter

    International Nuclear Information System (INIS)

    Lalrinmawia, Jonathan; Tiwari, Ramesh Chandra; Pau, Kham Suan

    2018-01-01

    This study aims at measuring the leakage radiation from X-ray tube and compare to national and international safety standard. The leakage radiation is formed at the anode inside the X-ray tube and transmitted through the tube housing. The tube housing is proposed to protect both patients and workers from leakage radiation. To the best of the authors' knowledge, no tube housing leakage measurements have been done so far in the present study area

  15. An experimental study of aerosol penetration through horizontal tubes and strom-type loops

    International Nuclear Information System (INIS)

    Wong, F.S.; McFarland, A.R.; Anand, N.K.

    1996-01-01

    Because some designers of aerosol transport systems use the assumption that aerosol penetration through a system is maximized of the flow Reynolds number is 2,800, we have conducted tests to determine if such an assumption is appropriate. Although we do not believe that optimal performance of an aerosol sample transport system can be presented solely in terms of the Reynolds number, we have presented our results in terms of that parameter to compare our work with the results of an earlier study. Two types of experiments were performed. First, the penetration of liquid aerosol particles through horizontal tubes was experimentally investigated for a range of design and operational conditions. For a particle size of 10 μm aerodynamic diameter, the maximum penetration through a 6.7 mm diameter tube was associated with a Reynolds number of approximately 2,000; the maximum penetration through a tube of 15.9 mm occurred at a Reynolds number of about 3,000; and the maximum penetration through a 26.7 mm diameter tube occurred at about 4,000. It was also experimentally demonstrated that for a fixed flow rate through a horizontal tube, there is an optimum tube diameter for which the aerosol penetration is a maximum. An early study dealing with aerosol particle penetration through a 16.8 mm inside diameter loop of tubing (two vertical tubes, two horizontal tubes and three 90 degrees bends) suggested there was a fixed Reynolds number for optimal aerosol penetration independent of particle size. Those experiments were repeated here and the agreement with those tests is excellent. 16 refs., 8 figs., 3 tabs

  16. X-ray phase imaging using a X-ray tube with a small focal spot. Improvement of image quality in mammography

    International Nuclear Information System (INIS)

    Honda, Chika; Ohara, Hiromu; Ishisaka, Akira; Shimada, Fumio

    2002-01-01

    Phase contrast X-ray imaging has been studied intensively using X-rays from synchrotron radiation and micro-focus X-ray tubes. However, these studies have revealed the difficulty of this technique's application to practical medical imaging. We have created a phase contrast imaging technique using a molybdenum X-ray tube with a small focal spot size for mammography. We identified the radiographic conditions in phase contrast magnification mammography with a screen-film system, where edge effect due to phase contrast overcomes geometrical unsharpness caused by the 0.1 mm-focal spot of a molybdenum X-ray tube. The edge enhancement due to phase imaging was observed in an image of a plastic tube, and then geometrical configuration of the X-ray tube, the object and the screen-film system was determined for phase imaging of mammography. In order to investigate a potential for medical application of this method, we conducted evaluation of the images of the American Collage of Radiology (ACR) 156 mammography phantom. We obtained higher scores for phase imaging using high speed screen-film systems without any increase of X-ray dose than the score for contract imaging using a standard speed screen-film system. (author)

  17. Characterization of flaws in a tube bundle mock-up for reliability studies

    International Nuclear Information System (INIS)

    Kupperman, D.S.; Bakhtiari, S.

    1997-01-01

    As part of an assessment of in-service inspection of steam generator tubes, the authors will assemble a steam generator mock-up for round robin studies and use as a test bed in evaluating emerging technologies. Progress is reported on the characterization of flaws that will be part of the mock-up. Eddy current and ultrasonic techniques are being evaluated as a means to characterize the flaws in the mock-up tubes before final assembly. Twenty Inconel 600 tubes with laboratory-grown cracks, typical of those to be used in the mock-up, were provided by Pacific Northwest National Laboratory for laboratory testing. After the tubes were inspected with eddy current and ultrasonic techniques, they were destructively analyzed to establish the actual depths, lengths, and profiles of the cracks. The analysis of the results will allow the best techniques to be used for characterizing the flaws in the mock-up tubes

  18. Characterization of flaws in a tube bundle mock-up for reliability studies

    International Nuclear Information System (INIS)

    Kupperman, D.S.; Bakhtiari, S.

    1996-10-01

    As part of an assessment of in-service inspection of steam generator tubes, the authors will assemble a steam generator mock-up for round robin studies and use as a test bed in evaluating emerging technologies. Progress is reported on the characterization of flaws that will be part of the mock-up. Eddy current and ultrasonic techniques are being evaluated as a means to characterize the flaws in the mock-up tubes before final assembly. Twenty Inconel 600 tubes with laboratory-grown cracks, typical of those to be used in the mock-up, were provided by Pacific Northwest National Laboratory for laboratory testing. After the tubes were inspected with eddy current and ultrasonic techniques, they were destructively analyzed to establish the actual depths, lengths, and profiles of the cracks. The analysis of the results will allow the best techniques to be used for characterizing the flaws in the mock-up tubes

  19. Feasibility study on the guided wave technique for condenser tube in NPP

    International Nuclear Information System (INIS)

    Choi, Sung Nam; Kim, Young Ho; Kim, Hyung Nam; Yoo, Hyun Joo; Hwang, W. G.

    2004-01-01

    The condenser tube is examined by the eddy current test (ECT) method to identify the integrity of the nuclear power plant. Because ECT probe is moved through the tube inside to identify flaws, the ECT probe should be exchanged periodically due to the wear of probe surface in order to remove the noise form the ECT signal. Moreover, it is impossible to examine the tube by ECT method because the ECT probe can not move through the inside due to the deformation such as dent. Recently, the theory of guided wave was established and the equipment applying the theory has been actively developed so as to overcome the limitation of ECT method for the tube inspection of heater exchanger in nuclear power plant. The object of this study is to know the feasibility of applying the guided wave technique to condenser tube in NPP

  20. A fluid density sensor based on a resonant tube

    International Nuclear Information System (INIS)

    Zhu, Yong; Dao, Dzung Viet; Woodfield, Peter

    2014-01-01

    A fluid density sensor based on resonance frequency change of a metallic tube is presented. The sensor has been developed without using a complex micro-fabrication process. The sensor is able to identify fluid types/contaminations and improve the performance by reducing testing time, decreasing complexity of testing equipment and reducing sample sizes. The sensor can measure the resonance frequency of its own structure and determine the change in resonance frequency due to the subsequent sample inside the tube. Numerical modelling, analytical modelling and physical testing of a prototype sensor showed comparable results for both the magnitude and resonance frequency shift. The modelling results yielded a resonance frequency shift of 200 Hz from 9.87 kHz to 9.67 kHz after the water was filled into the tube. The actual testing illustrated a resonance frequency change of 280 Hz from 9.11 kHz to 8.83 kHz. The ultimate aim of the work is to determine resonance frequencies of desired samples at a level that could detect genetic disease on a cellular level. (paper)

  1. Characterization of MicroRNA-200 pathway in ovarian cancer and serous intraepithelial carcinoma of fallopian tube.

    Science.gov (United States)

    Yang, Junzheng; Zhou, Yilan; Ng, Shu-Kay; Huang, Kuan-Chun; Ni, Xiaoyan; Choi, Pui-Wah; Hasselblatt, Kathleen; Muto, Michael G; Welch, William R; Berkowitz, Ross S; Ng, Shu-Wing

    2017-06-17

    Ovarian cancer is the leading cause of death among gynecologic diseases in Western countries. We have previously identified a miR-200-E-cadherin axis that plays an important role in ovarian inclusion cyst formation and tumor invasion. The purpose of this study was to determine if the miR-200 pathway is involved in the early stages of ovarian cancer pathogenesis by studying the expression levels of the pathway components in a panel of clinical ovarian tissues, and fallopian tube tissues harboring serous tubal intraepithelial carcinomas (STICs), a suggested precursor lesion for high-grade serous tumors. RNA prepared from ovarian and fallopian tube epithelial and stromal fibroblasts was subjected to quantitative real-time reverse-transcription polymerase chain reaction (qRT-PCR) to determine the expression of miR-200 families, target and effector genes and analyzed for clinical association. The effects of exogenous miR-200 on marker expression in normal cells were determined by qRT-PCR and fluorescence imaging after transfection of miR-200 precursors. Ovarian epithelial tumor cells showed concurrent up-regulation of miR-200, down-regulation of the four target genes (ZEB1, ZEB2, TGFβ1 and TGFβ2), and up-regulation of effector genes that were negatively regulated by the target genes. STIC tumor cells showed a similar trend of expression patterns, although the effects did not reach significance because of small sample sizes. Transfection of synthetic miR-200 precursors into normal ovarian surface epithelial (OSE) and fallopian tube epithelial (FTE) cells confirmed reduced expression of the target genes and elevated levels of the effector genes CDH1, CRB3 and EpCAM in both normal OSE and FTE cells. However, only FTE cells had a specific induction of CA125 after miR-200 precursor transfection. The activation of the miR-200 pathway may be an early event that renders the OSE and FTE cells more susceptible to oncogenic mutations and histologic differentiation. As high

  2. Improving accuracy of ET measurement of LISS nozzle to calandria tube clearance

    International Nuclear Information System (INIS)

    Craig, S.T.; Krause, T.W.; Schankula, J.J.

    2006-01-01

    The AECL Fuel Channel Inspection System (AFCIS) has been used in an in-reactor field trial to successfully measure the clearance between Liquid Injection Shutdown System (LISS) nozzles and calandria tubes. Each measurement over the full length of a channel added only 15 minutes to the on-channel inspection time. No changes were required to the inspection heads. The only equipment changes made were the addition of a Remote Field Eddy Current (RFEC) module to the eddy current instrument, and minor wiring changes, at the instrument, to achieve a RFEC configuration. With the experience gained from the field trial, factors potentially limiting accuracy were identified. These, and other factors, were investigated and are discussed herein. The RFEC probe is delivered inside the pressure tube. Magnetic fields from the RFEC probe extend through the conducting walls of the pressure tube and calandria tube to interact with the LISS nozzle. Data acquired during the field trial showed the LISS nozzle signal is distinct and the signal-to-noise ratio is very favourable. Nevertheless, comparison of the RFEC measurements to a visual examination, made during the same outage, had the RFEC method underestimating the clearance by 2.5 mm on average. By way of laboratory tests, the following factors were investigated as potential sources of error: resistivity and geometry of LISS nozzle reference/calibration pieces, pressure-tube wall thickness, diameter and resistivity variations, pressure-tube to calandria-tube gap, and radial offsets of the probe within the pressure-tube. The sensitivity to these various noise sources was established. A model, based on fundamental electromagnetic principles, was developed and was used to normalize the effects of LISS nozzle conductivity and geometry. This enabled compensation for various sources of error, and made it possible to produce a correction factor for the field trial data, reducing the average difference from the visual inspection of LISS

  3. Experimental study of flow friction characteristics of integral pin-fin tubes

    International Nuclear Information System (INIS)

    Ding Ming; Yan Changqi; Sun Licheng

    2007-01-01

    Friction characteristics of integral pin-fin tubes, through which lubricating-oil flowed vertically, were studied experimentally. Effects of the pitch, the height of fins and the machining direction on friction coefficient were analyzed. The experimental results showed that the friction coefficient of the integral pin-fro tube was obviously lager than that of smooth tube. Compared with other influential factors, the effect of the height of fins was dominant. Because the three-dimensional pin fin could disturb and destroy the boundary layer, when the Reynolds Number reached 200-300, the friction coefficient curve began to bend, that was, a turning point was appeared in the friction coefficient curve. (authors)

  4. USING LIGA BASED MICROFABRICATION TO IMPROVE OVERALL HEAT TRANSFER EFFICIENCY OF PRESSURIZED WATER REACTOR: I. Effects of Different Micro Pattern on Overall Heat Transfer

    International Nuclear Information System (INIS)

    Zhang, M.; Ibekwe, S.; Li, G.; Pang, S.S.; Lian, K.

    2006-01-01

    The Pressurized Water Reactors (PWRs in Figure 1) were originally developed for naval propulsion purposes, and then adapted to land-based applications. It has three parts: the reactor coolant system, the steam generator and the condenser. The Steam generator (a yellow area in Figure 1) is a shell and tube heat exchanger with high-pressure primary water passing through the tube side and lower pressure secondary feed water as well as steam passing through the shell side. Therefore, a key issue in increasing the efficiency of heat exchanger is to improve the design of steam generator, which is directly translated into economic benefits. The past research works show that the presence of a pin-fin array in a channel enhances the heat transfer significantly. Hence, using microfabrication techniques, such as LIGA, micro-molding or electroplating, some special microstructures can be fabricated around the tubes in the heat exchanger to increase the heat-exchanging efficiency and reduce the overall size of the heat-exchanger for the given heat transfer rates. In this paper, micro-pin fins of different densities made of SU-8 photoresist are fabricated and studied to evaluate overall heat transfer efficiency. The results show that there is an optimized micro pin-fin configuration that has the best overall heat transfer effects

  5. Application of laser-based profilometry to tubing in power generating utilities

    Science.gov (United States)

    Doyle, James L.

    1995-05-01

    Over the past several years lasers have been employed in an ever widening number of applications in an incredibly diverse set of markets. In the area of nondestructive testing, however, laser-based systems have only recently made inroads into the commercial markets. About ten years ago QUEST Integrated, Inc., began working with the U.S. Navy to adapt the principal of laser triangulation to solve a serious maintenance related problem. The internal surfaces of marine boiler tubes were experiencing pitting and corrosion which had resulted in catastrophic shipboard failures. At that time, conventional visual methods only allowed operators to inspect the first eighteen inches of the tube using a rigid borescope. If any pits were located, a mechanical stylus mechanism was used to obtain an approximate depth measurement of the pit. The condition of the balance of the tube was then extrapolated based on this extremely limited amount of information. Often the worst pitting was found in the bends of the tube, which could not be inspected by the visual method. Finally, a catastrophic boiler failure on an aircraft carrier resulted in the initiation of a search by the U.S. Navy for a better solution. Quest was contracted to develop an articulated probe which could negotiate the full length of a boiler tube with multiple bends, and generate a complete digital map of the inside surface. A key requirement of this probe would be rapid and quantitative measurement of internal features such as ID pits and corrosion. In 1987 QUEST delivered the first laser- optic tube inspection system to the U.S. Navy for use in marine boiler tubes. The Laser Optic Tube Inspection System (LOTISTM) was immediately put to use and paid for itself many times over in reduced maintenance costs. Over the next six years several generations of LOTIS were developed for the U.S. Navy, each one providing more capabilities, improved inspection speeds, and more user friendly operator interface. Today, LOTIS is

  6. Visual Iconic Patterns of Instant Messaging: Steps Towards Understanding Visual Conversations

    Science.gov (United States)

    Bays, Hillary

    An Instant Messaging (IM) conversation is a dynamic communication register made up of text, images, animation and sound played out on a screen with potentially several parallel conversations and activities all within a physical environment. This article first examines how best to capture this unique gestalt using in situ recording techniques (video, screen capture, XML logs) which highlight the micro-phenomenal level of the exchange and the macro-social level of the interaction. Of particular interest are smileys first as cultural artifacts in CMC in general then as linguistic markers. A brief taxonomy of these markers is proposed in an attempt to clarify their frequency and patterns of their use. Then, focus is placed on their importance as perceptual cues which facilitate communication, while also serving as emotive and emphatic functional markers. We try to demonstrate that the use of smileys and animation is not arbitrary but an organized interactional and structured practice. Finally, we discuss how the study of visual markers in IM could inform the study of other visual conversation codes, such as sign languages, which also have co-produced, physical behavior, suggesting the possibility of a visual phonology.

  7. Study on Influence of Tube Arrays on Fluid Elastic Instability

    Science.gov (United States)

    Ishihara, Kunihiko; Kitayama, Gen

    The tube bank is used in boilers, heat exchangers in power plants and steam generators in nuclear plants. These tubes sometimes vibrate violently and come to the fatigue failure due to the flow induced vibration which is caused by the cross flow. This phenomenon is that the large vibrations arise at the critical flow velocity and it is called fluid elastic instability. However the relation between the onset velocity of fluid elastic instability and the tube array's geometry has not been clarified sufficiently. There is a few reference related to the relation between the pitch to diameter ratio and the onset velocity even in the lattice arrays. In this paper, the influence of tube arrays on fluid elastic instability is examined by experiments. As a result, it is clarified that the tube vibrations become large as T/D increases and L/D decreases, and the tube vibrations strongly depend on the dynamic characteristics of tubes such as the natural frequency and the damping ability.

  8. Spatiotemporal study of gas heating mechanisms in a radio-frequency electrothermal plasma micro-thruster

    Directory of Open Access Journals (Sweden)

    Amelia eGreig

    2015-10-01

    Full Text Available A spatiotemporal study of neutral gas temperature during the first 100 s of operation for a radio-frequency electrothermal plasma micro-thruster operating on nitrogen at 60 W and 1.5 Torr is performed to identify the heating mechanisms involved. Neutral gas temperature is estimated from rovibrational band fitting of the nitrogen second positive system. A set of baffles are used to restrict the optical image and separate the heating mechanisms occurring in the central bulk discharge region and near the thruster walls.For each spatial region there are three distinct gas heating mechanisms being fast heating from ion-neutral collisions with timescales of tens of milliseconds, intermediate heating with timescales of 10 s from ion bombardment on the inner thruster tube surface creating wall heating, and slow heating with timescales of 100 s from gradual warming of the entire thruster housing. The results are discussed in relation to optimising the thermal properties of future thruster designs.

  9. A study on LMFBR steam generator design without tube failure propagation in water leak events

    International Nuclear Information System (INIS)

    Futagami, Satoshi; Hayafune, Hiroki; Fujimura, Ken; Sato, Mitsuru

    2009-01-01

    The major target performance of the SG for commercialized FBR is not only economic performance but also property protection performance. The candidate SG design will be selected at the end of JFY 2010. The straight double wall tube SG is one of the SG candidates for commercialized FBR, and other SG concepts were studied in this paper. In proposing an alternative SG, alternative technological measures with a double wall tube were investigated and included reinforcing the tube against wastage and quick detection of initial tube leaks. Alternative SG concept candidates for preventing tube failure propagation and mitigation of water leak accidents were proposed through a combination of technological measures. The candidates were then comparatively evaluated from the point of view of property protection performance, total weight, technological issues, and so on. A coated wall tube SG and protective wall tube SG were decided on as the alternative SGs because of superior property protection performance and with the technological issues. At the end of JFY 2010, the straight double wall tube SG will be decided upon as the result of R and D activities, and alternative SGs evaluated in feasibility studies. A plan for studying feasibility with the technological issues of the alternative SG was proposed. (author)

  10. Narratives From YouTube

    Directory of Open Access Journals (Sweden)

    Mikael Quennerstedt

    2013-10-01

    Full Text Available The aim of this paper is to explore what is performed in students’ and teachers’ actions in physical education practice in terms of “didactic irritations,” through an analysis of YouTube clips from 285 PE lessons from 27 different countries. Didactic irritations are occurrences that Rønholt describes as those demanding “didactic, pedagogical reflections and discussions, which in turn could lead to alternative thinking and understanding about teaching and learning.” Drawing on Barad’s ideas of performativity to challenge our habitual anthropocentric analytical gaze when looking at educational visual data, and using narrative construction, we also aim to give meaning to actions, relations, and experiences of the participants in the YouTube clips. To do this, we present juxtaposing narratives from teachers and students in terms of three “didactic irritations”: (a stories from a track, (b, stories from a game, and (c, stories from a bench. The stories re-present events-of-moving in the data offering insights into embodied experiences in PE practice, making students’ as well as teachers’ actions in PE practice understandable.

  11. Evolution of microstructure and mechanical properties of Al 6061 alloy tube in cyclic rotating bending process

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Zicheng, E-mail: zhangzicheng2004@126.com [School of Mechanical Engineering and Automation, Northeastern University, P.O. Box 319, No. 11 Lane 3, Wenhua Rd., Heping District, Shenyang 110819, Liaoning Province (China); Department of Mechanical Engineering, Tokyo Metropolitan University, 1-1 Minami-Osawa, Hachioji-shi, Tokyo (Japan); Shao, Shuai [School of Mechanical Engineering and Automation, Northeastern University, P.O. Box 319, No. 11 Lane 3, Wenhua Rd., Heping District, Shenyang 110819, Liaoning Province (China); Manabe, Ken-ichi [Department of Mechanical Engineering, Tokyo Metropolitan University, 1-1 Minami-Osawa, Hachioji-shi, Tokyo (Japan); Kong, Xiangwei [School of Mechanical Engineering and Automation, Northeastern University, P.O. Box 319, No. 11 Lane 3, Wenhua Rd., Heping District, Shenyang 110819, Liaoning Province (China); Li, Yanmei [State Key Laboratory of Rolling and Automation, Northeastern University, Shenyang 110004, Liaoning (China)

    2016-10-31

    To refine the microstructure and improve the mechanical properties of metal tubes, a new concept of severe plastic deformation process of cyclic rotating bending (CRB) was newly introduced. The current study focused on the investigation of evolution of microstructure and mechanical properties of Al 6061 tube in the CRB process with different deformation conditions. For this purpose, the CRB processes were performed with different deformation temperatures, bending angles and deformation times. The tensile test and Vickers hardness test were employed to evaluate the tensile properties and micro-hardness of the tube, respectively. While the Optical Microscope and Scanning Electronic Microscope equipped with Electron Back-Scattered Diffraction were utilized for the microstructure characterizations. The results shows that the deformation temperature, bending angle and deformation time have the strong influences on the mechanical properties and microstructure of the tubes processed by the CRB process. As a result, the tube with an average grain size of about 55 µm, as well as ultimate tensile strength of 244 MPa and total elongation of 10.05% was successfully obtained with the optimized deformation condition of the CRB process with a temperature of 100 °C, bending angle of 174°, the rotation speed of 20 r/min, and deformation time of 5 min, respectively.

  12. The vascular anatomy of the eustachian tube in the guinea pig.

    Science.gov (United States)

    Voorhees, R L

    1976-08-01

    Vascular anatomy of the eustachian tube has received little attention in the world's medical literature. Forty guinea pigs were perfused with Berlin Blue as a contrast medium and the eustachian tube microvascular architecture visualized through surface preparations. A diffuse, dense two-layered capillary network was found which followed the distribution of mucous glands. Five animals suffering from suppurative otitis media showed marked capillary congestion with increased vessel to tissue density. Relationships to gross arterial and venous supply as found in the human are discussed.

  13. Technical design report for the PANDA (AntiProton Annihilations at Darmstadt) Straw Tube Tracker

    NARCIS (Netherlands)

    Erni, W.; Keshelashvili, I.; Krusche, B.; Steinacher, M.; Heng, Y.; Liu, Z.; Liu, H.; Shen, X.; Wang, Q.; Xu, H.; Aab, A.; Albrecht, M.; Becker, J.; Csapo, A.; Feldbauer, F.; Fink, M.; Friedel, P.; Heinsius, F. H.; Held, T.; Klask, L.; Koch, H.; Kopf, B.; Leiber, S.; Leyhe, M.; Motzko, C.; Pelizaeus, M.; Pychy, J.; Roth, B.; Schroeder, T.; Schulze, J.; Sowa, C.; Steinke, M.; Trifterer, T.; Wiedner, U.; Zhong, J.; Beck, R.; Bianco, S.; Brinkmann, K. T.; Hammann, C.; Hinterberger, F.; Kaiser, D.; Kliemt, R.; Kube, M.; Pitka, A.; Quagli, T.; Schmidt, C.; Schmitz, R.; Schnell, R.; Thoma, U.; Vlasov, P.; Walther, D.; Wendel, C.; Wuerschig, T.; Zaunick, H. G.; Bianconi, A.; Bragadireanu, M.; Caprini, M.; Pantea, D.; Pantelica, D.; Pietreanu, D.; Serbina, L.; Tarta, P. D.; Kaplan, D.; Fiutowski, T.; Idzik, M.; Mindur, B.; Przyborowski, D.; Swientek, K.; Czech, B.; Kistryn, M.; Kliczewski, S.; Kozela, A.; Kulessa, P.; Lebiedowicz, P.; Pysz, K.; Schaefer, W.; Siudak, R.; Szczurek, A.; Jowzaee, S.; Kajetanowicz, M.; Kamys, B.; Kistryn, S.; Korcyl, G.; Korcyl, K.; Krzemien, W.; Magiera, A.; Moskal, P.; Palka, M.; Rudy, Z.; Salabura, P.; Smyrski, J.; Wronska, A.; Augustin, I.; Lehmann, I.; Nimorus, D.; Schepers, G.; Al-Turany, M.; Arora, R.; Deppe, H.; Flemming, H.; Gerhardt, A.; Goetzen, K.; Jordi, A. F.; Kalicy, G.; Karabowicz, R.; Lehmann, D.; Lewandowski, B.; Luehning, J.; Maas, F.; Orth, H.; Patsyuk, M.; Peters, K.; Saito, T.; Schepers, G.; Schmidt, C. J.; Schmitt, L.; Schwarz, C.; Schwiening, J.; Traxler, M.; Voss, B.; Wieczorek, P.; Wilms, A.; Zuehlsdorf, M.; Abazov, V. M.; Alexeev, G.; Arefiev, A.; Astakhov, V. I.; Barabanov, M. Yu.; Batyunya, B. V.; Davydov, Yu. I.; Dodokhov, V. Kh.; Efremov, A. A.; Fedunov, A. G.; Festchenko, A. A.; Galoyan, A. S.; Grigoryan, S.; Karmokov, A.; Koshurnikov, E. K.; Lobanov, V. I.; Lobanov, Yu. Yu.; Makarov, A. F.; Malinina, L. V.; Malyshev, V. L.; Mustafaev, G. A.; Olshevskiy, A.; Pasyuk, M. A.; Perevalova, E. A.; Piskun, A. A.; Pocheptsov, T. A.; Pontecorvo, G.; Rodionov, V. K.; Rogov, Yu. N.; Salmin, R. A.; Samartsev, A. G.; Sapozhnikov, M. G.; Shabratova, G. S.; Skachkova, A. N.; Skachkov, N. B.; Strokovsky, E. A.; Suleimanov, M. K.; Teshev, R. Sh.; Tokmenin, V. V.; Uzhinsky, V. V.; Vodopyanov, A. S.; Zaporozhets, S. A.; Zhuravlev, N. I.; Zorin, A. G.; Branford, D.; Glazier, D.; Watts, D.; Woods, P.; Britting, A.; Eyrich, W.; Lehmann, A.; Uhlig, F.; Dobbs, S.; Metreveli, Z.; Seth, K.; Tomaradze, A.; Xiao, T.; Bettoni, D.; Carassiti, V.; Ramusino, A. Cotta; Dalpiaz, P.; Drago, A.; Fioravanti, E.; Garzia, I.; Savrie, M.; Stancari, G.; Bianchi, N.; Gianotti, P.; Guaraldo, C.; Lucherini, V.; Orecchini, D.; Pace, E.; Bersani, A.; Bracco, G.; Macri, M.; Parodi, R. F.; Bremer, D.; Dormenev, V.; Drexler, P.; Dueren, M.; Eissner, T.; Foehl, K.; Galuska, M.; Gessler, T.; Hayrapetyan, A.; Hu, J.; Koch, P.; Kroeck, B.; Kuehn, W.; Lange, S.; Liang, Y.; Merle, O.; Metag, V.; Moritz, M.; Muenchow, D.; Nanova, M.; Novotny, R.; Spruck, B.; Stenzel, H.; Ullrich, T.; Werner, M.; Xu, H.; Euan, C.; Hoek, M.; Ireland, D.; Keri, T.; Montgomery, R.; Protopopescu, D.; Rosner, G.; Seitz, B.; Babai, M.; Glazenborg-Kluttig, A.; Kavatsyuk, M.; Lemmens, P.; Lindemulder, M.; Löhner, H.; Messchendorp, J.; Moeini, H.; Schakel, P.; Schreuder, F.; Smit, H.; Tambave, G.; van der Weele, J. C.; Veenstra, Rick; Sohlbach, H.; Buescher, M.; Deermann, D.; Dosdall, R.; Esch, S.; Gillitzer, A.; Goldenbaum, F.; Grunwald, D.; Henssler, S.; Herten, A.; Hu, Q.; Kemmerling, G.; Kleines, H.; Kozlov, V.; Lehrach, A.; Maier, R.; Mertens, M.; Ohm, H.; Orfanitski, S.; Prasuhn, D.; Randriamalala, T.; Ritman, J.; Roeder, M.; Schadmand, S.; Serdyuk, V.; Sterzenbach, G.; Stockmanns, T.; Wintz, P.; Wuestner, P.; Xu, H.; Kisiel, J.; Li, S.; Li, Z.; Sun, Z.; Xu, H.; Rigato, V.; Fissum, S.; Hansen, K.; Isaksson, L.; Lundin, M.; Schroder, B.; Achenbach, P.; Bleser, S.; Cahit, U.; Cardinali, M.; Denig, A.; Distler, M.; Fritsch, M.; Jasinski, P.; Kangh, D.; Karavdina, A.; Lauth, W.; Merkel, H.; Michel, M.; Espi, M. C. Mora; Mueller, U.; Pochodzalla, J.; Sanchez, S.; Sanchez-Lorente, A.; Schlimme, S.; Sfienti, C.; Thiel, M.; Weber, T.; Dormenev, V. I.; Fedorov, A. A.; Korzhik, M. V.; Missevitch, O. V.; Balanutsa, V.; Chernetsky, V.; Demekhin, A.; Dolgolenko, A.; Fedorets, P.; Gerasimov, A.; Goryachev, V.; Varentsov, V.; Boukharov, A.; Malyshev, O.; Marishev, I.; Semenov, A.; Boehmer, F.; Dorheim, S.; Ketzer, B.; Paul, S.; Hergemoeller, A. K.; Khoukaz, A.; Koehler, E.; Taeschner, A.; Wessels, J.; Varma, R.; Chaterjee, A.; Jha, V.; Kailas, S.; Roy, B. J.; Yan, Y.; Chinorat, K.; Khanchai, K.; Ayut, L.; Pomrad, S.; Baldin, E.; Kotov, K.; Peleganchuk, S.; Tikhonov, Yu.; Boucher, J.; Chambert, V.; Dbeyssi, A.; Gumberidze, M.; Hennino, T.; Imre, M.; Kunne, R.; Le Galliard, C.; Ma, B.; Marchand, D.; Maroni, A.; Ong, S.; Ramstein, B.; Rosier, P.; Tomasi-Gustafsson, E.; De Wiele, J. Van; Boca, G.; Braghieri, A.; Costanza, S.; Genova, P.; Lavezzi, L.; Montagna, P.; Rotondi, A.; Abramov, V.; Belikov, N.; Davidenko, A.; Derevschikov, A.; Goncharenko, Y.; Grishin, V.; Kachanov, V.; Konstantinov, D.; Kormilitsin, V.; Melnik, Y.; Levin, A.; Minaev, N.; Mochalov, V.; Morozov, D.; Nogach, L.; Poslavskiy, S.; Ryazantsev, A.; Ryzhikov, S.; Semenov, P.; Shein, I.; Uzunian, A.; Vasiliev, A.; Yakutin, A.; Back, T.; Cederwall, B.; Makonyi, K.; Tegner, P. E.; von Wurtemberg, K. M.; Belostotski, S.; Gavrilov, G.; Itzotov, A.; Kashchuk, A.; Kisselev, A.; Kravchenko, P.; Levitskaya, O.; Manaenkov, S.; Miklukho, O.; Naryshkin, Y.; Veretennikov, D.; Vikhrov, V.; Zhadanov, A.; Alberto, D.; Amoroso, A.; Bussa, M. P.; Busso, L.; De Mori, F.; Destefanis, M.; Fava, L.; Ferrero, L.; Greco, M.; Maggiora, M.; Marcello, S.; Sosio, S.; Spataro, S.; Zotti, L.; Calvo, D.; Coli, S.; De Remigis, P.; Filippi, A.; Giraudo, G.; Lusso, S.; Mazza, G.; Morra, O.; Rivetti, A.; Wheadon, R.; Iazzi, F.; Lavagno, A.; Younis, H.; Birsa, R.; Bradamante, F.; Bressan, A.; Martin, A.; Clement, H.; Galander, B.; Balkestahl, L. Caldeira; Calen, H.; Fransson, K.; Johansson, T.; Kupsc, A.; Marciniewski, P.; Thome, E.; Wolke, M.; Zlomanczuk, J.; Diaz, J.; Ortiz, A.; Dmowski, K.; Duda, P.; Korzeniewski, R.; Slowinski, B.; Chlopik, A.; Guzik, Z.; Kosinski, K.; Melnychuk, D.; Wasilewski, A.; Wojciechowski, M.; Wronka, S.; Wysocka, A.; Zwieglinski, B.; Buehler, P.; Hartman, O. N.; Kienle, P.; Marton, J.; Suzuki, K.; Widmann, E.; Zmeskal, J.; Werner, M.J.

    This document describes the technical layout and the expected performance of the Straw Tube Tracker (STT), the main tracking detector of the PANDA target spectrometer. The STT encloses a Micro-Vertex-Detector (MVD) for the inner tracking and is followed in beam direction by a set of GEM stations.

  14. [An epidemiological study of visual disability and visual rehabilitation in Beijing].

    Science.gov (United States)

    Zou, Yan-hong; Ding, Ji-yuan; Peng, Hong; Shi, Ji-liang; Qu, Cheng-yi; Liu, Xi-pu

    2009-12-01

    To investigate the status of visual disability and the demands for visual rehabilitation services in Beijing. Five hundred and fifty-five persons with visual disability in Beijing from the Second National Survey on Disability of China were involved in this study. Their visual disability and demands for rehabilitation were evaluated. About three fourth of the visual disabled persons were over 60 years of age. Cataract, retinal and choroidal diseases, and glaucoma were the three leading causes of the visual impairment. Medical service was the number one (82.0%) demand for the persons with visual disability, although 89.4% of them had previously received some kinds of medial services. People who had received visual aid devices or rehabilitation training were 26.7% and 5.8%, respectively, while more people showed their demand for these service (36.6% and 11.9%, respectively). The demand for visual rehabilitation varied in different groups of age and severity of disability. Accessibility of high quality medical services for preventable blindness diseases should be further promoted. Public health education on visual rehabilitation is also needed.

  15. Comparison of clinical and physical measures of image quality in chest and pelvis computed radiography at different tube voltages

    International Nuclear Information System (INIS)

    Sandborg, Michael; Tingberg, Anders; Ullman, Gustaf; Dance, David R.; Alm Carlsson, Gudrun

    2006-01-01

    The aim of this work was to study the dependence of image quality in digital chest and pelvis radiography on tube voltage, and to explore correlations between clinical and physical measures of image quality. The effect on image quality of tube voltage in these two examinations was assessed using two methods. The first method relies on radiologists' observations of images of an anthropomorphic phantom, and the second method was based on computer modeling of the imaging system using an anthropomorphic voxel phantom. The tube voltage was varied within a broad range (50-150 kV), including those values typically used with screen-film radiography. The tube charge was altered so that the same effective dose was achieved for each projection. Two x-ray units were employed using a computed radiography (CR) image detector with standard tube filtration and antiscatter device. Clinical image quality was assessed by a group of radiologists using a visual grading analysis (VGA) technique based on the revised CEC image criteria. Physical image quality was derived from a Monte Carlo computer model in terms of the signal-to-noise ratio, SNR, of anatomical structures corresponding to the image criteria. Both the VGAS (visual grading analysis score) and SNR decrease with increasing tube voltage in both chest PA and pelvis AP examinations, indicating superior performance if lower tube voltages are employed. Hence, a positive correlation between clinical and physical measures of image quality was found. The pros and cons of using lower tube voltages with CR digital radiography than typically used in analog screen-film radiography are discussed, as well as the relevance of using VGAS and quantum-noise SNR as measures of image quality in pelvis and chest radiography

  16. Automation in tube finishing bay

    International Nuclear Information System (INIS)

    Bhatnagar, Prateek; Satyadev, B.; Raghuraman, S.; Syama Sundara Rao, B.

    1997-01-01

    Automation concept in tube finishing bay, introduced after the final pass annealing of PHWR tubes resulted in integration of number of sub-systems in synchronisation with each other to produce final cut fuel tubes of specified length, tube finish etc. The tube finishing bay which was physically segregated into four distinct areas: 1. tube spreader and stacking area, 2. I.D. sand blasting area, 3. end conditioning, wad blowing, end capping and O.D. wet grinding area, 4. tube inspection, tube cutting and stacking area has been studied

  17. In-situ, real time micro-CT imaging of pore scale processes, the next frontier for laboratory based micro-CT scanning

    OpenAIRE

    Boone, Marijn; Bultreys, Tom; Masschaele, Bert; Van Loo, Denis; Van Hoorebeke, Luc; Cnudde, Veerle

    2016-01-01

    Over the past decade, laboratory based X-ray computed micro-tomography (micro-CT) has given unique insights in the internal structure of complex reservoir rocks, improving the understanding of pore scale processes and providing crucial information for pore scale modelling. Especially in-situ imaging using X-ray optimized Hassler type cells has enabled the direct visualization of fluid distributions at the pore scale under reservoir conditions. While sub-micrometre spatial resolutions are achi...

  18. Operative behaviour of a condenser tube under ETA chemistry

    International Nuclear Information System (INIS)

    Chocron, Mauricio; Burkart, Arturo; Rodriguez, Ivanna; Raul, Manera; Diego, Quinteros

    2012-09-01

    Among the various recommendations for the surveillance of the integrity of the materials of the Secondary Cycle (Balance of Plant) it is the periodic removal of a steam generator tube and a condenser tube and their analysis. It considers assessment of the water chemistry, corrosion and the reciprocal effect on or from other components of the cycle. Embalse N.P.P. is a CANDU 6 type, Pressurized Heavy Water Reactor, located in Cordoba Province, Argentina. Previous papers have shown results on tubes removed from the steam generators (Bordoni et al., NPC'08, September 15-18, 2008, Berlin, Germany; 6 th Canadian Nuclear Society - Steam Generators Conference, November 8-11, 2009, Toronto, Canada). Considering that the Embalse BOP has mixed metallurgy, i.e., steam generator tubes made of A800, piping made of ferrous alloys and condenser tubes made of Admiralty Brass and also taking into account that the chemistry has been modified from Morpholine control to ETA control (Fernandez et. al, NPC'2010, October 3-7, Quebec City, Canada), it has been decided to remove and analyze a condenser tube that has been placed in operation coincidently with the establishment of the ETA chemical control. The extraction is dated along with the November 2011 Plant Programmed Outage. Objectives are assessing the operative behavior of the tube performing visual and optical microscope inspection, SEM analysis of the oxides and deposits in exposed surfaces and occluded locations like tube sheet and other tests as well. Results are compared to the same analysis performed on a new tube in storage and integrated with the chemical operative figures of the cycle during the period: chemical data and corrosion products transport. (authors)

  19. Study of drift tube resolution using numerical simulations

    International Nuclear Information System (INIS)

    Lundin, M.C.

    1990-01-01

    The results off a simulation of straw tube detector response are presented. These gas ionization detectors and the electronics which must presumably go along with them are characterized in a simple but meaningful manner. The physical processes which comprise the response of the individual straw tubes are broken down and examined in detail. Different parameters of the simulation are varied and resulting predictions of drift tube spatial resolution are shown. In addition, small aspects of the predictions are compared to recent laboratory results, which can be seen as a measure of the simulation's usefulness. 10 refs., 8 figs

  20. An experimental investigation of hydrodynamic cavitation in micro-Venturis

    Science.gov (United States)

    Mishra, Chandan; Peles, Yoav

    2006-10-01

    The existence of hydrodynamic cavitation in the flow of de-ionized water through micro-Venturis has been witnessed in the form of traveling bubble cavitation and fully developed streamer bubble/supercavitation, and their mechanisms have been discussed. High-speed photography and flow visualization disclose inchoate cavitation bubbles emerging downstream from the micro-Venturi throat and the presence of a single streamer bubble/supercavity, which is equidistant from the micro device walls. The supercavity initiates inside the diffuser section and extends until the microchannel exit and proceeds to bifurcate the incoming flow. This article strives to provide numerical data and experimental details of hydrodynamic cavitation taking place within micro-Venturis.

  1. A Trip from a Tube to a Chip Applied Micro and Nanotechnology in Biotechnology, Veterinary and Life Sciences

    DEFF Research Database (Denmark)

    Bang, Dang Duong; Dhumpa, Raghuram; Cao, Cuong

    2010-01-01

    of such pathogens. Microchipfabrication has had a major impact on electronics and is expected to have an equally pronounced effect on life sciences. By combining micro-fluidics with micromechanics, micro-optics, and microelectronics, systems can be realized to perform complete chemical or biochemical analyses......-nanotechnology in life sciences will be given. In addition, examples of DNA micro arrays, micro fabricated integrated PCR chips and total integrated lab-on-chip systems from different National and EU research projects being carried out at the Laboratory of Applied Micro-Nanotechnology (LAMINATE) group at the National...

  2. An experimental study on the impact collapse characteristics of CF/Epoxy circular tubes

    International Nuclear Information System (INIS)

    Kim, Y.N.; Im, K.H.; Park, J.W.; Yang, I.Y.

    2003-01-01

    This study is to investigate the energy absorption characteristics of CF/Epoxy (Carbon-Fiber/Epoxy Resin) circular tubes in static and impact tests. The experimental results varied significantly as a function of interlaminar number, orientation angle of outer and trigger. When a CFRP composite tube is crushed, static/impact energy is consumed by friction between the loading plate and the splayed fronds of the tube, by fracture of the fibers, matrix and their interface, and the response is complex and depends on the interaction among the different mechanisms, such as transverse shearing, laminar bending and local buckling. The collapse mode depended upon orientation angle of outer of CFRP tubes and loading status(static/impact). Typical collapse modes of CFRP tubes are wedge collapse mode, splaying collapse mode and fragmentation collapse mode

  3. Preliminary Study on Biosynthesis of Bacterial Nanocellulose Tubes in a Novel Double-Silicone-Tube Bioreactor for Potential Vascular Prosthesis

    Directory of Open Access Journals (Sweden)

    Feng Hong

    2015-01-01

    Full Text Available Bacterial nanocellulose (BNC has demonstrated a tempting prospect for applications in substitute of small blood vessels. However, present technology is inefficient in production and BNC tubes have a layered structure that may bring danger after implanting. Double oxygen-permeable silicone tubes in different diameters were therefore used as a tube-shape mold and also as oxygenated supports to construct a novel bioreactor for production of the tubular BNC materials. Double cannula technology was used to produce tubular BNC via cultivations with Acetobacter xylinum, and Kombucha, a symbiosis of acetic acid bacteria and yeasts. The results indicated that Kombucha gave higher yield and productivity of BNC than A. xylinum. Bacterial nanocellulose was simultaneously synthesized both on the inner surface of the outer silicone tube and on the outer surface of the inner silicone tube. Finally, the nano BNC fibrils from two directions formed a BNC tube with good structural integrity. Scanning electron microscopy inspection showed that the tubular BNC had a multilayer structure in the beginning but finally it disappeared and an intact BNC tube formed. The mechanical properties of BNC tubes were comparable with the reported value in literatures, demonstrating a great potential in vascular implants or in functional substitutes in biomedicine.

  4. Preliminary Study on Biosynthesis of Bacterial Nanocellulose Tubes in a Novel Double-Silicone-Tube Bioreactor for Potential Vascular Prosthesis.

    Science.gov (United States)

    Hong, Feng; Wei, Bin; Chen, Lin

    2015-01-01

    Bacterial nanocellulose (BNC) has demonstrated a tempting prospect for applications in substitute of small blood vessels. However, present technology is inefficient in production and BNC tubes have a layered structure that may bring danger after implanting. Double oxygen-permeable silicone tubes in different diameters were therefore used as a tube-shape mold and also as oxygenated supports to construct a novel bioreactor for production of the tubular BNC materials. Double cannula technology was used to produce tubular BNC via cultivations with Acetobacter xylinum, and Kombucha, a symbiosis of acetic acid bacteria and yeasts. The results indicated that Kombucha gave higher yield and productivity of BNC than A. xylinum. Bacterial nanocellulose was simultaneously synthesized both on the inner surface of the outer silicone tube and on the outer surface of the inner silicone tube. Finally, the nano BNC fibrils from two directions formed a BNC tube with good structural integrity. Scanning electron microscopy inspection showed that the tubular BNC had a multilayer structure in the beginning but finally it disappeared and an intact BNC tube formed. The mechanical properties of BNC tubes were comparable with the reported value in literatures, demonstrating a great potential in vascular implants or in functional substitutes in biomedicine.

  5. Preliminary Study on Biosynthesis of Bacterial Nanocellulose Tubes in a Novel Double-Silicone-Tube Bioreactor for Potential Vascular Prosthesis

    Science.gov (United States)

    Wei, Bin; Chen, Lin

    2015-01-01

    Bacterial nanocellulose (BNC) has demonstrated a tempting prospect for applications in substitute of small blood vessels. However, present technology is inefficient in production and BNC tubes have a layered structure that may bring danger after implanting. Double oxygen-permeable silicone tubes in different diameters were therefore used as a tube-shape mold and also as oxygenated supports to construct a novel bioreactor for production of the tubular BNC materials. Double cannula technology was used to produce tubular BNC via cultivations with Acetobacter xylinum, and Kombucha, a symbiosis of acetic acid bacteria and yeasts. The results indicated that Kombucha gave higher yield and productivity of BNC than A. xylinum. Bacterial nanocellulose was simultaneously synthesized both on the inner surface of the outer silicone tube and on the outer surface of the inner silicone tube. Finally, the nano BNC fibrils from two directions formed a BNC tube with good structural integrity. Scanning electron microscopy inspection showed that the tubular BNC had a multilayer structure in the beginning but finally it disappeared and an intact BNC tube formed. The mechanical properties of BNC tubes were comparable with the reported value in literatures, demonstrating a great potential in vascular implants or in functional substitutes in biomedicine. PMID:26090420

  6. A comparison of tape-tying versus a tube-holding device for securing endotracheal tubes in adults.

    Science.gov (United States)

    Murdoch, E; Holdgate, A

    2007-10-01

    During the transfer of intubated patients, endotracheal tube security is paramount. This study aims to compare two methods of securing an endotracheal tube in adults: tying with a cloth tape versus the Thomas Endotracheal Tube Holder (Laerdal). A manikin-based study was performed using paramedics and critical care doctors (consultants and senior trainees) as participants. Each participant was asked to secure an endotracheal tube that had been placed within the trachea of a manikin a total of six times, the first three times using tied cloth tape and the last three times using a Thomas Endotracheal Tube Holder. Following each 'fixation' and after the participant had left the room, the security of the tube was tested by applying a fixed force laterally and to the right by dropping a 1.25 kg weight a distance of 50 cm. The amount of movement of the tube with respect to the teeth was measured and recorded in millimetres. Two-hundred-and-seventy tube fixations (135 tied vs. 135 tube holder) were performed by 45 participants. The degree of tube movement was significantly higher when the tube was secured with a tie compared with when the tube holder was used (median movement 22 mm vs. 4 mm, P tube holder device minimised tube movement in a manikin model when compared with conventional tape tying. The use of this device when transporting intubated patients may reduce the risk of tube displacement though further clinical studies are warranted.

  7. Occult pneumothorax in blunt trauma: is there a need for tube thoracostomy?

    Science.gov (United States)

    Zhang, M; Teo, L T; Goh, M H; Leow, J; Go, K T S

    2016-12-01

    Occult pneumothorax (OPTX) is defined as air within the pleural cavity that is undetectable on normal chest X-rays, but identifiable on computed tomography. Currently, consensus is divided between tube thoracostomy and conservative management for OPTX. The aim of this retrospective study is to determine whether OPTX can be managed conservatively and whether any adverse events occur under conservative management. Data on all trauma patients from 1 Jan 2010 to 31 December 2012 were obtained from our hospital's trauma registry. All patients with occult pneumothorax who had chest X-ray (CXR) and any CT scan visualizing the thorax were included. The exclusion criteria included those with penetrating wounds; CXR showing pneumothorax, hemothorax, or hemopneumothorax; those with prophylactic chest tube insertion before CT; and those with no CT diagnosis of OPTX. The complications of these patients were analyzed to determine if tube thoracostomy is necessary for OPTX and whether not inserting it would alter the outcome significantly. A total of 1564 cases were reviewed and 83 patients were included. Of these 83 patients, 35 (42.2 %) had tube thoracostomy after OPTX detection and 48 (57.8 %) were observed initially. Patients who had tube thoracostomy had similar ISS compared to those without (median ISS 17 vs. 18.5, p = 0.436). Out of the 48 patients who did not have tube thoracostomy on detection of an OPTX, 4 (8.3 %) had complications. In the group of 35 patients who had tube thoracostomy on detection of an OPTX, 7 (20 %) had complications. Of the 83 patients, a total of 12 patients had IPPV, of which 7 (58.3 %) had tube thoracostomy and 5 (41.7 %) did not. Patients who had tube thoracostomy under our care have a statistically significant likelihood of experiencing any complication compared to those without tube thoracostomy (odds ratio 9.92. The median length of stay was also longer (13 days) in those who had tube thoracostomy compared to those without (5

  8. An investigation on SA 213-Tube to SA 387-Tube plate using friction welding process

    Energy Technology Data Exchange (ETDEWEB)

    Rajan, S. Pandia; Kumaraswamidhas, L. A. [Indian Institute of Technology, Jharkhand (India); Kumaran, S. Senthil [RVS School of Engineering and Technology, Tamil Nadu (India); Muthukumaran, S. [National Institute of Technology, Tamil Nadu (India)

    2016-01-15

    Friction welding of tube to tube plate using an external tool (FWTPET) is a relatively newer solid state welding process used for joining tube to tube plate of either similar or dissimilar materials with enhanced mechanical and metallurgical properties. In the present study, FWTPET has been used to weld SA 213 (Grade T12) tube with SA 387 (Grade 22) tube plate. The welded samples are found to have satisfactory joint strength and the Energy dispersive X-ray analysis (EDX), X-ray diffraction (XRD) study showed that inter metallic compound is absent in the weld zone. The different weld joints have been identified and the phase composition is found using EDX and XRD. Microstructures have been analyzed using optical and Scanning electron microscopy (SEM). The mechanical properties such as hardness, compressive shear strength and peel test for different weld conditions are studied and the hardness survey revealed that there is increase in hardness at the weld interface due to grain refinement. The corrosion behavior for different weld conditions have been analyzed and the weld zone is found to have better corrosion resistance due to the influence of the grain refinement after FWTPET welding process. Hence, the present investigation is carried out to study the behavior of friction welded dissimilar joints of SA 213 tube and SA 387 tube plate joints and the results are presented. The present study confirms that a high quality tube to tube plate joint can be achieved using FWTPET process at 1120 rpm.

  9. Flow visualization system for wind turbines without blades applied to micro reactors; Sistema de visualização de escoamento para turbinas sem lâminas aplicada a microrreatores

    Energy Technology Data Exchange (ETDEWEB)

    Santos, G.S.B., E-mail: siqueira.gsb@gmail.com [Universidade Estadual Paulista Julio de Mesquita Filho (UNESP), São José dos Campos, SP (Brazil); Guimarães, L.N.F. [Instituto de Estudos Avançados (IEAv), São José dos Campos, SP (Brazil). Departamento de Ciência e Tecnologia Aeroespacial; Placco, G.M. [Instituto Tecnológico de Aeronáutica (PG/CTE/ITA), São José dos Campos, SP (Brazil). Departamento de Ciência e Tecnologia Aeroespacial

    2017-07-01

    Flow visualization systems is a tool used in science and industry for characterization of projects that operate with drainage. This work presents the design and construction of a flow visualization system for passive turbines used in advanced fast micro reactors. In the system were generated images where it is possible to see the supersonic and transonic flow through the turbine disks. A test bench was assembled to generate images of the interior of the turbine where the flow is supersonic, allowing the study of the behavior of the boundary layer between disks. It is necessary to characterize the boundary layer of this type of turbine because its operation occurs in the transfer of kinetic energy between the fluid and the disks. The images generated, as well as their analyzes are presented as a result of this work.

  10. Transient CFD studies on multiple jets issuing from injection tube

    International Nuclear Information System (INIS)

    Kumawat, Ganesh Lal; Kansal, Anuj Kumar; Maheshwari, Naresh Kumar; Rama Rao, A.

    2016-01-01

    Shut down system 2 of Advanced Heavy Water reactor incorporates the injection of liquid poison into moderator through injection tubes. The injection tubes consist of several holes distributed axially and circumferentially. Investigation of the poison jet progression and spreading from the holes of injection tube is important aspect of determining negative reactivity injection rate. This paper presents the CFD simulation to investigate poison jet progression and its spreading from the holes of injection tube. (author)

  11. Plugging criteria for steam generator tubes with axial cracks near tube support plates

    International Nuclear Information System (INIS)

    Mattar Neto, Miguel

    2000-01-01

    Stress corrosion cracking with intergranular attack occurs on the secondary side of steam generator (SG) tubes where impurities concentrate due to boiling under restricted flow conditions. In the most of cases, it can be called ODSCC (Outer Diameter Stress Corrosion Cracking). The typical locations are areas near support plates, in sludge piles and at top of tubesheet crevices. Though it can also occur on free spans under the relatively thin deposits that build up on the tube surfaces. ODSCC near tube plate supports have been the cause of plugging of many tubes. Thus, studies on SG tubes plugging criteria related to this degradation mechanism are presented in this paper. Th purpose is to avoid unnecessary tube plugging from either safety or reliability standpoint. Based on these studies some conclusions on the plugging criteria and on the difficulties to apply them are addressed. (author)

  12. Development and performance of inspection equipment for pressure tubes in Fugen

    International Nuclear Information System (INIS)

    Naruo, Kazuteru; Tanimoto, Ken-ichi; Ohta, Takeo; Nakamura, Takahisa; Imaizumi, Kiyoshi.

    1984-01-01

    The pressure tubes of Fugen are the important equipment as the many tubes compose the core, and since they are made of Zr-2.5% Nb alloy which has been used for the first time in Japan, they have become the object of monitoring (the follow-up investigation of the change of inside diameter, the presence of defects and so on) in addition to the in-service inspection. In this paper, on the inspection equipment for pressure tubes, that has been developed independently by the Power Reactor and Nuclear Fuel Development Corp. in order to carry out the ISI and monitoring, the course of development and the construction and the performance are reported, and the results of having used it for the fourth regular inspection of Fugen are described. The 10-year plan of the ISI and monitoring of pressure tubes is shown. The core of Fugen is composed of 224 pressure tubes, therefore, the inspection is carried out by sampling inspection. The monitoring is carried out on four tubes for the follow-up investigation and one tube that shows the severest operation history at the time of inspection. The equipment performs ultrasonic flaw detection, the measurement of inside diameter and the visual inspection of internal surface. (Kako, I.)

  13. Experimental study of curved guide tubes for pellet injection

    International Nuclear Information System (INIS)

    Combs, S.K.; Baylor, L.R.; Foust, C.R.; Gouge, M.J.; Jernigan, T.C.; Milora, S.L.

    1997-01-01

    The use of curved guide tubes for transporting frozen hydrogen pellets offers great flexibility for pellet injection into plasma devices. While this technique has been previously employed, an increased interest in its applicability has been generated with the recent ASDEX Upgrade experimental data for magnetic high-field side (HFS) pellet injection. In these innovative experiments, the pellet penetration appeared to be significantly deeper than for the standard magnetic low-field side injection scheme, along with corresponding greater fueling efficiencies. Thus, some of the major experimental fusion devices are planning experiments with HFS pellet injection. Because of the complex geometries of experimental fusion devices, installations with multiple curved guide tube sections will be required for HFS pellet injection. To more thoroughly understand and document the capability of curved guide tubes, an experimental study is under way at the Oak Ridge National Laboratory (ORNL). In particular, configurations and pellet parameters applicable for the DIII-D tokamak and the International Thermonuclear Experimental Reactor (ITER) were simulated in laboratory experiments. Initial test results with nominal 2.7- and 10-mm-diam deuterium pellets are presented and discussed

  14. New closed tube loop mediated isothermal amplification assay for prevention of product cross-contamination.

    Science.gov (United States)

    Karthik, K; Rathore, Rajesh; Thomas, Prasad; Arun, T R; Viswas, K N; Dhama, Kuldeep; Agarwal, R K

    2014-01-01

    Loop mediated isothermal amplification (LAMP) assay, a promising diagnostic test, has been developed for detection of different pathogens of human as well as animals. Various positive points support its use as a field level test but the major problem is product cross contamination leading to false positive results. Different methods were adopted by various researchers to control this false positive amplification due to cross contamination but all have their own advantages and disadvantages. A new closed tube LAMP assay based on agar dye capsule was developed in the present study and this technique has some advantages over the other closed tube technique.•Agar at the concentration of 1.5% was used to sandwich SYBR green dye I with the aid of intradermal syringe. This agar dye capsule was placed over the LAMP reaction mixture before it was amplified.•To eliminate the hazardous nature of Ultra Violet (UV) light during result visualization of LAMP products, the present study demonstrates the use of Light Emitting Diode (LED) lights for result visualization.•LAMP was carried out for Brucella species detection using this modified techniques yielding good results without any cross contamination and LED showed similar fluorescence compared to UV.

  15. High-resolution three-dimensional visualization of the rat spinal cord microvasculature by synchrotron radiation micro-CT

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Jianzhong; Cao, Yong; Wu, Tianding; Li, Dongzhe [Department of Spine Surgery, Xiangya Hospital, Central South University, Changsha 410008 (China); Lu, Hongbin, E-mail: hongbinlu@hotmail.com [Department of Sports Medicine, Research Centre of Sports Medicine, Xiangya Hospital, Central South University, Changsha 410008 (China)

    2014-10-15

    Purpose: Understanding the three-dimensional (3D) morphology of the spinal cord microvasculature has been limited by the lack of an effective high-resolution imaging technique. In this study, synchrotron radiation microcomputed tomography (SRµCT), a novel imaging technique based on absorption imaging, was evaluated with regard to the detection of the 3D morphology of the rat spinal cord microvasculature. Methods: Ten Sprague-Dawley rats were used in this ex vivo study. After contrast agent perfusion, their spinal cords were isolated and scanned using conventional x-rays, conventional micro-CT (CµCT), and SRµCT. Results: Based on contrast agent perfusion, the microvasculature of the rat spinal cord was clearly visualized for the first time ex vivo in 3D by means of SRµCT scanning. Compared to conventional imaging techniques, SRµCT achieved higher resolution 3D vascular imaging, with the smallest vessel that could be distinguished approximately 7.4 μm in diameter. Additionally, a 3D pseudocolored image of the spinal cord microvasculature was generated in a single session of SRµCT imaging, which was conducive to detailed observation of the vessel morphology. Conclusions: The results of this study indicated that SRµCT scanning could provide higher resolution images of the vascular network of the spinal cord. This modality also has the potential to serve as a powerful imaging tool for the investigation of morphology changes in the 3D angioarchitecture of the neurovasculature in preclinical research.

  16. Heat transfer characteristics of alkali metals flowing across tube banks

    International Nuclear Information System (INIS)

    Sugiyama, K.; Ishiguro, R.; Kojima, Y.; Kanaoka, H.

    2004-01-01

    For the purpose of getting heat transfer coefficients of alkali metals flowing across tube banks at an acceptable level, we propose to use an inviscid-irrotational flow model, which is based on our flow visualization experiment. We show that the heat transfer coefficients obtained for the condition where only the test rod is heated in tube banks considerably differ from those obtained for the condition where all the rods are heated, because of interference between thick thermal boundary layers of alkali metals. We also confirm that the analytical values obtained by this flow model are in a reasonable agreement with experimental values. (author)

  17. Tube bundle vibrations due to cross flow under the influence of turbulence

    Energy Technology Data Exchange (ETDEWEB)

    Popp, K.; Romberg, O. [Institute of Mechanics, University of Hannover (Germany)

    1998-10-01

    Tube bundles are often used in heat exchangers and chemical reactors. Besides of large heat transfer capacities and small pressure drops in the apparatus a safe design against vibration damages is demanded. For many years extensive investigations concerning the dynamical behaviour of tube bundles subjected to cross-flow have been carried out in the wind tunnel of the Institute of Mechanics at the University of Hannover. In the last years the investigations were concentrated on the experimental investigations of different flow excitation mechanisms in a fully flexible bundle as well as in a bundle with one single flexibly mounted tube in an otherwise fixed array with variable geometry and changing equilibrium position. The aim of the studies was the determination of the stability boundaries, i.e. the critical reduced fluid velocity depending on the reduced damping coefficient in a wide parameter region. Theoretical investigations of the stability behaviour on the basis of an one dimensional flow model as well as experimental investigations of the influence of turbulence on the stability boundaries have been carried out. Here, for certain tube bundle configurations an increased turbulence has a stabilizing effect and leads to a shift of the stability boundaries to higher velocities. The change of the turbulence was realised by using turbulence grids at the inlet of the bundles or thin Prandtl-tripwires at the tube surfaces. Flow visualization studies at the original experimental set-up under relevant Reynolds numbers give an impression of the flow pattern. At this time an investigation of the exciting fluid forces is carried out using a flexibly mounted pressure test tube. A survey about some recent investigations is given. (orig.)

  18. Tubing misconnections: normalization of deviance.

    Science.gov (United States)

    Simmons, Debora; Symes, Lene; Guenter, Peggi; Graves, Krisanne

    2011-06-01

    Accidental connection of an enteral system to an intravenous (IV) system frequently results in the death of the patient. Misconnections are commonly attributed to the presence of universal connectors found in the majority of patient care tubing systems. Universal connectors allow for tubing misconnections between physiologically incompatible systems. The purpose of this review of case studies of tubing misconnections and of current expert recommendations for safe tubing connections was to answer the following questions: In tubing connections that have the potential for misconnections between enteral and IV tubing, what are the threats to safety? What are patient outcomes following misconnections between enteral and IV tubing? What are the current recommendations for preventing misconnections between enteral and IV tubing? Following an extensive literature search and guided by 2 models of threats and errors, the authors analyzed case studies and expert opinions to identify technical, organizational, and human errors; patient-related threats; patient outcomes; and recommendations. A total of 116 case studies were found in 34 publications. Each involved misconnections of tubes carrying feedings, intended for enteral routes, to IV lines. Overwhelmingly, the recommendations were for redesign to eliminate universal connectors and prevent misconnections. Other recommendations were made, but the analysis indicates they would not prevent all misconnections. This review of the published case studies and current expert recommendations supports a redesign of connectors to ensure incompatibility between enteral and IV systems. Despite the cumulative evidence, little progress has been made to safeguard patients from tubing misconnections.

  19. Stability and Behaviors of Methane/Propane and Hydrogen Micro Flames

    Science.gov (United States)

    Yoshimoto, Takamitsu; Kinoshita, Koichiro; Kitamura, Hideki; Tanigawa, Ryoichi

    The flame stability limits essentially define the fundamental operation of the combustion system. Recently the micro diffusion flame has been remarked. The critical conditions of the flame stability limit are highly dependent on nozzle diameter, species of fuel and so on. The micro diffusion flame of Methane/Propane and Hydrogen is formed by using the micro-scale nozzle of which inner diameter is less than 1mm. The configurations and behaviors of the flame are observed directly and visualized by the high speed video camera The criteria of stability limits are proposed for the micro diffusion flame. The objectives of the present study are to get further understanding of lifting/blow-off for the micro diffusion flame. The results obtained are as follows. (1) The behaviors of the flames are classified into some regions for each diffusion flame. (2) The micro diffusion flame of Methane/Propane cannot be sustained, when the nozzle diameter is less than 0.14 mm. (3) The diffusion flame cannot be sustained below the critical fuel flow rate. (4) The minimum flow which is formed does not depends on the average jet velocity, but on the fuel flow rate. (5) the micro flame is laminar. The flame length is decided by fuel flow rate.

  20. The Improved SVM Multi Objects' Identification For the Uncalibrated Visual Servoing

    Directory of Open Access Journals (Sweden)

    Min Wang

    2009-03-01

    Full Text Available For the assembly of multi micro objects in micromanipulation, the first task is to identify multi micro parts. We present an improved support vector machine algorithm, which employs invariant moments based edge extraction to obtain feature attribute and then presents a heuristic attribute reduction algorithm based on rough set's discernibility matrix to obtain attribute reduction, with using support vector machine to identify and classify the targets. The visual servoing is the second task. For avoiding the complicated calibration of intrinsic parameter of camera, We apply an improved broyden's method to estimate the image jacobian matrix online, which employs chebyshev polynomial to construct a cost function to approximate the optimization value, obtaining a fast convergence for online estimation. Last, a two DOF visual controller based fuzzy adaptive PD control law for micro-manipulation is presented. The experiments of micro-assembly of micro parts in microscopes confirm that the proposed methods are effective and feasible.

  1. The Improved SVM Multi Objects's Identification for the Uncalibrated Visual Servoing

    Directory of Open Access Journals (Sweden)

    Xiangjin Zeng

    2009-03-01

    Full Text Available For the assembly of multi micro objects in micromanipulation, the first task is to identify multi micro parts. We present an improved support vector machine algorithm, which employs invariant moments based edge extraction to obtain feature attribute and then presents a heuristic attribute reduction algorithm based on rough set's discernibility matrix to obtain attribute reduction, with using support vector machine to identify and classify the targets. The visual servoing is the second task. For avoiding the complicated calibration of intrinsic parameter of camera, We apply an improved broyden's method to estimate the image jacobian matrix online, which employs chebyshev polynomial to construct a cost function to approximate the optimization value, obtaining a fast convergence for online estimation. Last, a two DOF visual controller based fuzzy adaptive PD control law for micro-manipulation is presented. The experiments of micro-assembly of micro parts in microscopes confirm that the proposed methods are effective and feasible.

  2. Computational study of a low head draft tube and validation with experimental data

    Energy Technology Data Exchange (ETDEWEB)

    Henau, V De; Payette, F A; Sabourin, M [Alstom Power Systems, Hydro 1350 chemin Saint-Roch, Sorel-Tracy (Quebec), J3R 5P9 (Canada); Deschenes, C; Gagnon, J M; Gouin, P, E-mail: vincent.dehenau@power.alstom.co [Hydraulic Machinery Laboratory, Laval University 1065 ave. de la Medecine, Quebec (Canada)

    2010-08-15

    The objective of this paper is to investigate methodologies to improve the reliability of CFD analysis of low head turbine draft tubes. When only the draft tube performance is investigated, the study indicates that draft tube only simulations with an adequate treatment of the inlet boundary conditions for velocity and turbulence are a good alternative to rotor/stator (stage) simulations. The definition of the inlet velocity in the near wall regions is critical to get an agreement between the stage and draft tube only solutions. An average turbulent kinetic energy intensity level and average turbulent kinetic energy dissipation length scale are sufficient as turbulence inlet conditions as long as these averages are coherent with the stage solution. Comparisons of the rotor/stator simulation results to the experimental data highlight some discrepancies between the predicted draft tube flow and the experimental observations.

  3. A Concentric Tube Continuum Robot with Piezoelectric Actuation for MRI-Guided Closed-Loop Targeting

    OpenAIRE

    Su, Hao; Li, Gang; Rucker, D. Caleb; Webster, Robert J.; Fischer, Gregory S.

    2016-01-01

    This paper presents the design, modeling and experimental evaluation of a magnetic resonance imaging (MRI)-compatible concentric tube continuum robotic system. This system enables MRI-guided deployment of a precurved and steerable concentric tube continuum mechanism, and is suitable for clinical applications where a curved trajectory is needed. This compact 6 degree-of-freedom (DOF) robotic system is piezoelectrically-actuated, and allows simultaneous robot motion and imaging with no visually...

  4. Failure analysis of burst tested fuel tube samples

    International Nuclear Information System (INIS)

    Padmaprabu, C.; Ramana Rao, S.V.; Srivatsava, R.K.

    2005-01-01

    The Total Circumferential Elongation (TCE) is an important parameter for evaluation of ductility of the Zircaloy-4 fuel tubes for the PHWR reactors. The TCE values of the fuel tubes were obtained using the burst testing technique. In some lots there is a variation in the values of the TCE. To investigate the reasons for such a large variation in the TCE, samples were selected at appropriate intervals and sectioned at the fractured portion. The surface morphology of the fractured surfaces was examined under Scanning Electron Microscope (SEM) equipped with Energy Dispersive Spectrometer (EDS). The morphologies show segregation of elements at specific locations. Energy dispersive spectra was obtained from those segregated particles. According to the magnitude of TCE value the samples were classified into low, intermediate and high ductility. Low ductility samples were found to contain large amount of segregations along the thickness direction of the tube. This forms a brittle region and a path for the easy crack growth along thickness direction. In the case of intermediate samples the segregation occurred in fewer locations compared to low ductile samples and also confined to the circumferential direction of the outside surface of the tube. Due to this, probability of crack formation at the surface of the tube could be high. But crack growth would be slower in the ductile matrix along the thickness direction resulting in the enhancement of TCE value compared to the low ductile sample. In the high ductile samples, the segregations were very scarce and found to be isolated and embedded in the ductile matrix. The mode of failure in these types of samples was found to be purely ductile. Cracks were found to originate solely from the micro voids in the material. As the probability of crack formation and its propagation is low, very high TCE values were observed in these samples. Microstructural observations of fractured surfaces and EDAX analysis was able to identify the

  5. The vascularization of a gastric tube as a substitute for the esophagus is affected by its diameter.

    Science.gov (United States)

    Pierie, J P; de Graaf, P W; van Vroonhoven, T J; Obertop, H

    1998-10-01

    The stomach is used for reconstruction of the upper gastrointestinal tract after esophageal resection for cancer. The whole stomach can be used, but also a wide or narrow gastric tube can be constructed. Short-term functional results are superior after use of a narrow tube. Healing of the cervical esophagogastrostomy can be impaired, leading to leakage and stricture. The decreased vascularization at the site of the anastomosis may be one reason. It was hypothesized that the quality of the vascularization of the gastric tube, used as a substitute for the oesophagus after esophagectomy, depends on its diameter. The vascularization of postmortem specimens was studied using angiography. Whole stomachs (3), wide (3) and narrow gastric tubes (3) were constructed. In a patient with an anastomotic stricture of a narrow tube with a cervical esophagogastrostomy vascularisation was evaluated by angiography. After infusion of contrast through the supplying arteries, the whole stomachs and wide gastric tubes showed adequate vascularization, whereas the narrow gastric tube showed poor vascularization especially at the site of the anastomosis. In narrow gastric tubes, the right gastroepiploic artery was the only feeding artery. In the patient's angiography, a limited contrast visualization of the proximal end of the gastric tube could be demonstrated. Although a narrow gastric tube is favoured by some surgeons, the use of whole stomach or a type of gastric tube with preservation of the right gastric artery may lead to a better anastomotic healing.

  6. Studies of the steam generator degraded tubes behavior on BRUTUS test loop

    Energy Technology Data Exchange (ETDEWEB)

    Chedeau, C.; Rassineux, B. [EDF/DER/MTC, Moret Sur Loing (France); Flesch, B. [EDF/EPN/DMAINT, Paris (France)] [and others

    1997-04-01

    Studies for the evaluation of steam generator tube bundle cracks in PWR power plants are described. Global tests of crack leak rates and numerical calculations of crack opening area are discussed in some detail. A brief overview of thermohydraulic studies and the development of a mechanical probabilistic design code is also given. The COMPROMIS computer code was used in the studies to quantify the influence of in-service inspections and maintenance work on the risk of a steam generator tube rupture.

  7. Study of the sealing performance of tubing adapters in gas-tight deep-sea water sampler

    Directory of Open Access Journals (Sweden)

    Huang Haocai

    2014-09-01

    Full Text Available Tubing adapter is a key connection device in Gas-Tight Deep-Sea Water Sampler (GTWS. The sealing performance of the tubing adapter directly affects the GTWS’s overall gas tightness. Tubing adapters with good sealing performance can ensure the transmission of seawater samples without gas leakage and can be repeatedly used. However, the sealing performance of tubing adapters made of different materials was not studied sufficiently. With the research discussed in this paper, the materials match schemes of the tubing adapters were proposed. With non-linear finite element contact analysis and sea trials in the South China Sea, it is expected that the recommended materials match schemes not only meet the requirements of tubing adapters' sealing performance but also provide the feasible options for the following research on tubing adapters in GTWS

  8. Study of the sealing performance of tubing adapters in gas-tight deep-sea water sampler

    Directory of Open Access Journals (Sweden)

    Haocai Huang

    2014-09-01

    Full Text Available Tubing adapter is a key connection device in Gas-Tight Deep-Sea Water Sampler (GTWS. The sealing performance of the tubing adapter directly affects the GTWS's overall gas tightness. Tubing adapters with good sealing performance can ensure the transmission of seawater samples without gas leakage and can be repeatedly used. However, the sealing performance of tubing adapters made of different materials was not studied sufficiently. With the research discussed in this paper, the materials match schemes of the tubing adapters were proposed. With non-linear finite element contact analysis and sea trials in the South China Sea, it is expected that the recommended materials match schemes not only meet the requirements of tubing adapters’ sealing performance but also provide the feasible options for the following research on tubing adapters in GTWS.

  9. Learning from YouTube [Video Book

    Science.gov (United States)

    Juhasz, Alexandra

    2011-01-01

    YouTube is a mess. YouTube is for amateurs. YouTube dissolves the real. YouTube is host to inconceivable combos. YouTube is best for corporate-made community. YouTube is badly baked. These are a few of the things Media Studies professor Alexandra Juhasz (and her class) learned about YouTube when she set out to investigate what actually happens…

  10. Fluid Dynamics of a Novel Micro-Fistula Implant for the Surgical Treatment of Glaucoma.

    Science.gov (United States)

    Sheybani, Arsham; Reitsamer, Herbert; Ahmed, Iqbal Ike K

    2015-07-01

    The purpose of this study was to describe the fluidics of a novel non-valved glaucoma implant designed to prevent hypotony and compare the fluidics of this device with two commonly used non-valved glaucoma devices. The XEN 45 micro-fistula implant was designed to limit hypotony by virtue of its length and width according to the Hagen-Poiseuille equation. Flow testing was performed using a syringe pump and pressure transducer at multiple flow rates. The pressure differentials across the XEN implant, the Ex-Press implant, and 10 mm of silicone tubing from a Baerveldt implant at a physiologic flow rate (2.5 μL/min) were extrapolated. The XEN 45 achieved a steady-state pressure calculated at 7.56 mm Hg at 2.5 μL/min. At the same flow rate, the Ex-Press device and Baerveldt tubing reached steady-state pressures of 0.09 and 0.01 mm Hg, respectively. Under flow testing, the XEN micro-fistula implant was able to maintain backpressure above numerical hypotony levels without the use of complex valve systems. This is due to the XEN implant's design, derived from the principles that dictate Newtonian fluids.

  11. Study on manufacturing technology of fuel guide tube using HANA alloys

    International Nuclear Information System (INIS)

    Kim, Hyungil; Jung, Yangil; Park, Dongjun; Park, Jeongyong; Kim, Ilhyun; Choi, Byungkwon; Jeong, Yonghwan; Park, Sangyoon

    2013-04-01

    This research was focused on the study for the manufacturing technology of HANA alloys to crease the corrosion resistance of 30% as well as the to improve the strength of 10% when compared to the commercial zirconium alloys. The new manufacturing concept having higher corrosion resistance and strength than commercial alloy performance can be obtained in this research. This result was transferred to the KNF and, that will be commercialized. This research result can be summarized like this; Ο Parameter study to increase formability of HANA alloy tube - Study on alloy element and heat-treatment effect - Study on texture development mechanism - Study on final annealing effect Ο Out-of-pile performance evaluation of HANA alloy tube - Corrosion performance evaluation of HANA alloy manufactured at KNF - Mechanical performance evaluation of HANA alloy manufactured at KNF - Recrystallization behavior evaluation of HANA alloy manufactured at KNF - Texture characterization of HANA alloy manufactured at KNF - Microstructure characterization of HANA alloy manufactured at KNF Ο Manufacturing guideline setup to increase formability of HANA alloy tube - Manufacturing guideline setup to decrease surface defect - Manufacturing guideline setup to increase strength and corrosion resistance - Manufacturing guideline setup to control texture

  12. Moderator mixing after a pressure tube failure

    International Nuclear Information System (INIS)

    MacKinnon, J.C.; Fortman, R.A.; Hadaller, G.I.

    1997-01-01

    contents of the paper are as follows. First, the objectives of the experimental program are summarized, and a description of the facility is given, with a discussion of the loop modifications required to perform the mixing study. Then a description of the conditions studied during commissioning in the Moderator Test Facility is given. Results obtained during the commissioning, both flow visualization and measurements, are presented. Lastly, an overview of the tests to be performed during the remainder of the program is given. (author)

  13. Study of thermo-fluidic behavior of micro-droplet in inkjet-based micro manufacturing processes

    Science.gov (United States)

    Das, Raju; Mahapatra, Abhijit; Ball, Amit Kumar; Roy, Shibendu Shekhar; Murmu, Naresh Chandra

    2017-06-01

    Inkjet printing technology, a maskless, non-contact patterning operation, which has been a revelation in the field of micro and nano manufacturing for its use in the selective deposition of desired materials. It is becoming an exciting alternative technology such as lithography to print functional material on to a substrate. Selective deposition of functional materials on desired substrates is a basic requirement in many of the printing based micro and nano manufacturing operations like the fabrication of microelectronic devices, solar cell, Light-emitting Diode (LED) research fields like pharmaceutical industries for drug discovery purposes and in biotechnology to make DNA microarrays. In this paper, an attempt has been made to design and develop an indigenous Electrohydrodynamic Inkjet printing system for micro fabrication and to study the interrelationships between various thermos-fluidic parameters of the ink material in the printing process. The effect of printing process parameters on printing performance characteristics has also been studied. And the applicability of the process has also been experimentally demonstrated. The experimentally found results were quite satisfactory and accordance to its applicability.

  14. Flash photolysis-shock tube studies

    Energy Technology Data Exchange (ETDEWEB)

    Michael, J.V. [Argonne National Laboratory, IL (United States)

    1993-12-01

    Even though this project in the past has concentrated on the measurement of thermal bimolecular reactions of atomic species with stable molecules by the flash or laser photolysis-shock tube (FP- or LP-ST) method using atomic resonance absorption spectrometry (ARAS) as the diagnostic technique, during the past year the authors have concentrated on studies of the thermal decompositions of selected chlorocarbon molecules. These studies are necessary if the degradation of chlorine containing organic molecules by incineration are to be understood at the molecular level. Clearly, destruction of these molecules will not only involve abstraction reactions, when possible, but also thermal decomposition followed by secondary reactions of the initially formed atoms and radicals. Studies on the thermal decomposition of CH{sub 3}Cl are complete, and the curve-of-growth for Cl-atom atomic resonance absorption has been determined. The new thermal decomposition studies are similar to those already reported for CH{sub 3}Cl.

  15. Chemical kinetics studies at high temperatures using shock tubes

    OpenAIRE

    Rajakumar, B; Anandraj, D; Reddy, KPJ; Arunan, E

    2002-01-01

    Shock tube is an unique facility to create temperature gradients exceeding million degrees Kelvin per second. We have established two shock tubes for measuring the kinetic reaction rates at high temperatures with two different but complementary detection techniques. The first one is a single pulse shock tube, in which the reflected shock is used to heat the molecules. The equilibrated products are analyzed by gas chromatograph and infrared spectrometer. The second one uses laser-schlieren sys...

  16. Study on metallization on RX tubes of fluoroscopic equipment

    International Nuclear Information System (INIS)

    Ramos Caballero, L. J.; Angulo Pain, E.; Iborra Oquendo, M. a.; Seguro Fernandez, A.

    2013-01-01

    The PECCRD sets values for the performance of a team of rays x as a function of the total filtration of this (for 80 KV, a total filtration [2.5, 5] mm's to the). However it is recommended to check if the RX tube had metallization by exhaustion (part of anode tungsten evaporates and lining the inside of the envelope of the tube). This effect produces an increase in filtration tube and a decrease in performance. (Author)

  17. X-ray micro computed tomography for the visualization of an atherosclerotic human coronary artery

    Science.gov (United States)

    Matviykiv, Sofiya; Buscema, Marzia; Deyhle, Hans; Pfohl, Thomas; Zumbuehl, Andreas; Saxer, Till; Müller, Bert

    2017-06-01

    Atherosclerosis refers to narrowing or blocking of blood vessels that can lead to a heart attack, chest pain or stroke. Constricted segments of diseased arteries exhibit considerably increased wall shear stress, compared to the healthy ones. One of the possibilities to improve patient’s treatment is the application of nano-therapeutic approaches, based on shear stress sensitive nano-containers. In order to tailor the chemical composition and subsequent physical properties of such liposomes, one has to know precisely the morphology of critically stenosed arteries at micrometre resolution. It is often obtained by means of histology, which has the drawback of offering only two-dimensional information. Additionally, it requires the artery to be decalcified before sectioning, which might lead to deformations within the tissue. Micro computed tomography (μCT) enables the three-dimensional (3D) visualization of soft and hard tissues at micrometre level. μCT allows lumen segmentation that is crucial for subsequent flow simulation analysis. In this communication, tomographic images of a human coronary artery before and after decalcification are qualitatively and quantitatively compared. We analyse the cross section of the diseased human coronary artery before and after decalcification, and calculate the lumen area of both samples.

  18. Is a drain tube necessary for minimally invasive lumbar spine fusion surgery?

    Science.gov (United States)

    Hung, Pei-I; Chang, Ming-Chau; Chou, Po-Hsin; Lin, Hsi-Hsien; Wang, Shih-Tien; Liu, Chien-Lin

    2017-03-01

    This study aimed to evaluate if closed suction wound drainage is necessary in minimally invasive surgery of transforaminal lumbar interbody fusion (MIS TLIF). This is a prospective randomized clinical study. Fifty-six patients who underwent MIS TLIF were randomly divided into groups A (with a closed suction wound drainage) and B (without tube drainage). Surgical duration, intraoperative blood loss, timing of ambulation, length of hospital stay and complications were recorded. Patients were followed up for an average of 25.3 months. Clinical outcome was assessed using the Oswestry disability index and visual analogue scale (VAS). Fusion rate was classified with the Bridwell grading system, based on plain radiograph. Both groups had similar patient demographics. The use of drains had no significant influence on perioperative parameters including operative time, estimated blood loss, length of stay and complications. Patients in group B started ambulation 1 day earlier than patients in group A (p drain tube can lead to pain, anxiety and discomfort during the postoperative period. We conclude that drain tubes are not necessary for MIS TLIF. Patients without drains had the benefit of earlier ambulation than those with drains.

  19. Characteristics of Transmission-type Microfocus X-ray Tube based-on Carbon Nanotube Field Emitter

    International Nuclear Information System (INIS)

    Heo, Sung Hwan; Ihsan, Aamir; Cho, Sung Oh

    2007-01-01

    A high resolution microfocus x-ray source is widely applied to noninvasive detection for industrial demands, material science and engineering, and to diagnostic study of microbiology and micro-tomography. Carbon nanotube (CNT) is regarded as an excellent electron emitter, which outperforms conventional electron sources in point of brightness. It has been suggested that CNT is used as an electron source of a high resolution x-ray tube according to their low threshold field with atomically sharp geometry, chemically robust structure, and electric conductivity. Several researchers have reported miniaturized x-ray tube based on diode structure and micro x-ray radiography and computed tomography systems using triode types with precise emission control and electrostatic focusing. Especially, a microfocus x-ray source of 30 μm resolution has been demonstrated recently using an elliptical CNT cathode and asymmetrical Eingel lens. However, to increase the spatial resolution of x-ray source, a smaller CNT emitter is desired. Electron focusing optics must be corrected to reduce aberrations. A thin wire tip end can provide a micro-area of CNT substrate, and a magnetic lens and transmission x-ray target are proper to reduce the lens aberration and a focal length. Until now, CNT based microfocus x-ray source with less than 10 um resolution has not been shown. Here we report a microfocus x-ray source with 4.7 μm x-ray focal spot consisted of a conical CNT tip, a single solenoid lens, and a transmission type x-ray target. A magnified x-ray image larger than 230 times was resolved with advantage of microfocused focal spot and transmission x-ray target

  20. CFD Studies on Triangular Micro-Vortex Generators in Flow Control

    Science.gov (United States)

    Yashodhar, V.; Humrutha, G.; Kaushik, M.; Khan, S. A.

    2017-03-01

    In the present study, the flow characteristics of the commercially used S809 wind turbine airfoil controlled with triangular counter-rotating micro-vortex generators at stall angle of attack of 15 degrees and 10 m/s, 15 m/s and 20 m/s (speed range used in the wind turbine applications) had been computationally investigated. In addition to the controlled airfoil, an uncontrolled airfoil was also studied for the comparison. The modelling and analysis had been carried out using incompressible, Reynolds Averaged Navier Stokes equation using Spalart-Allmaras one equation turbulence model. The numerical computations were performed with SIMPLE algorithm. The velocity profiles at different locations on the suction surface were plotted for both uncontrolled and controlled airfoils. The shear stresses exerted on the upper surface of the airfoil in both the configurations were also compared. It is found that the controlled airfoil, the shear stress distribution was greatly increased near to trailing edge of the airfoil revealing the superiority of vortex generators in increasing the efficiency of wind turbine by delaying boundary layer separation. The qualitative results of flow visualization in the spanwise direction also support the quantitative findings of velocity profiles and shear stress distribution.

  1. Bioactive surface modifications on inner walls of poly-tetra-fluoro-ethylene tubes using dielectric barrier discharge

    Science.gov (United States)

    Cho, Yong Ki; Park, Daewon; Kim, Hoonbae; Lee, Hyerim; Park, Heonyong; Kim, Hong Ja; Jung, Donggeun

    2014-03-01

    Bioactive surface modification can be used in a variety of medical polymeric materials in the fields of biochips and biosensors, artificial membranes, and vascular grafts. In this study, the surface modification of the inner walls of poly-tetra-fluoro-ethylene (PTFE) tubing was carried out to improve vascular grafts, which are made of biocompatible material for the human body in the medical field. Focus was centered on the cell attachment of the inner wall of the PTFE by sequential processes of hydrogen plasma treatment, hydrocarbon deposition, and reactive plasma treatment on the PFTE surface using micro plasma discharge. Micro plasma was generated by a medium-frequency alternating current high-voltage generator. The preliminary modification of PTFE was conducted by a plasma of hydrogen and argon gases. The hydrocarbon thin film was deposited on modified PTFE with a mixture of acetylene and argon gases. The reactive plasma treatment using oxygen plasma was done to give biocompatible functionality to the inner wall surface. The hydrophobic surface of bare PTFE is made hydrophilic by the reactive plasma treatment due to the formation of carbonyl groups on the surface. The reactive treatment could lead to improved attachment of smooth muscle cells (SMCs) on the modified PTFE tubing. Fourier transform infrared absorption spectroscopy, X-ray photoelectron spectroscopy, scanning electron microscopy, and water contact angle measurement were used for the analysis of the surface modification. The SMC-attached PTFE tube developed will be applicable to in vitro human vasculature-mimetic model systems, and to medical vascular grafts.

  2. 21 CFR 868.5800 - Tracheostomy tube and tube cuff.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Tracheostomy tube and tube cuff. 868.5800 Section... (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5800 Tracheostomy tube and tube cuff. (a) Identification. A tracheostomy tube and tube cuff is a device intended to be placed into a...

  3. Micro-Valences: Affective valence in neutral everyday objects

    Directory of Open Access Journals (Sweden)

    Sophie eLebrecht

    2012-04-01

    Full Text Available Affective valence influences both our cognition and our perception of the world. Indeed, the speed and quality with which we recognize objects in a visual scene can vary dramatically depending on its affective content. However, affective processing of visual objects has been typically studied using only stimuli with strong affective valences (e.g., guns or roses. Here we explore whether affective valence must be strong or obvious to exert an effect on our perception. We conclude that the majority of objects carry some affective valence (micro-valences and, thus, nominally neutral objects are not really neutral. Functionally, the perception of valence in everyday objects facilitates perceptually-driven choice behavior, decision-making, and affective responses.

  4. The miR-124 family of microRNAs is crucial for regeneration of the brain and visual system in the planarian Schmidtea mediterranea.

    Science.gov (United States)

    Sasidharan, Vidyanand; Marepally, Srujan; Elliott, Sarah A; Baid, Srishti; Lakshmanan, Vairavan; Nayyar, Nishtha; Bansal, Dhiru; Sánchez Alvarado, Alejandro; Vemula, Praveen Kumar; Palakodeti, Dasaradhi

    2017-09-15

    Brain regeneration in planarians is mediated by precise spatiotemporal control of gene expression and is crucial for multiple aspects of neurogenesis. However, the mechanisms underpinning the gene regulation essential for brain regeneration are largely unknown. Here, we investigated the role of the miR-124 family of microRNAs in planarian brain regeneration. The miR-124 family ( miR-124 ) is highly conserved in animals and regulates neurogenesis by facilitating neural differentiation, yet its role in neural wiring and brain organization is not known. We developed a novel method for delivering anti-miRs using liposomes for the functional knockdown of microRNAs. Smed-miR-124 knockdown revealed a key role for these microRNAs in neuronal organization during planarian brain regeneration. Our results also demonstrated an essential role for miR-124 in the generation of eye progenitors. Additionally, miR-124 regulates Smed-slit-1 , which encodes an axon guidance protein, either by targeting slit-1 mRNA or, potentially, by modulating the canonical Notch pathway. Together, our results reveal a role for miR-124 in regulating the regeneration of a functional brain and visual system. © 2017. Published by The Company of Biologists Ltd.

  5. Flow pattern assessment in tubes with wire coil inserts in laminar and transition regimes

    International Nuclear Information System (INIS)

    Garcia, A.; Solano, J.P.; Vicente, P.G.; Viedma, A.

    2007-01-01

    The paper presents an analysis of the flow mechanisms in tubes with wire coils using hydrogen bubble visualization and PIV techniques. Results have been contrasted with experimental data on pressure drop. The relation between the observed flow patterns and the friction factor has been analysed. The experimental analysis that has been carried out allows one to state that at low Reynolds numbers (Re < 400) the flow in tubes with wire coils is basically similar to the flow in smooth tubes. At Reynolds numbers between 500 and 700 and in short pitch wire coils a recirculating flow appears. The insertion of wires coils in a smooth tube accelerates significantly the transition to turbulence. This is produced at Reynolds numbers between 700 and 1000 depending on the wire pitch

  6. Development and preliminary experimental study on micro-stacked insulator

    International Nuclear Information System (INIS)

    Ren Chengyan; Yuan Weiqun; Zhang Dongdong; Yan Ping; Wang Jue

    2009-01-01

    High gradient insulating technology is one of the key technologies in new type dielectric wall accelerator(DWA). High gradient insulator, namely micro-stacked insulator, was developed and preliminary experimental study was done. Based on the finite element and particle simulating method, surface electric field distribution and electron movement track of micro-stacked insulator were numerated, and then the optimized design proposal was put forward. Using high temperature laminated method, we developed micro-stacked insulator samples which uses exhaustive fluorinated ethylene propylene(FEP) as dielectric layer and stainless steel as metal layer. Preliminary experiment of vacuum surface flashover in nanosecond pulse voltage was done and micro-stacked insulator exhibited favorable vacuum surface flashover performance with flashover field strength of near 180 kV/cm. (authors)

  7. Micro Information Systems

    DEFF Research Database (Denmark)

    Ulslev Pedersen, Rasmus; Kühn Pedersen, Mogens

    2014-01-01

    such as medical and manufacturing. These new sensor applications have implications for information systems (IS) and, the authors visualize this new class of information systems as fractals growing from an established class of systems; namely that of information systems (IS). The identified applications...... and implications are used as an empirical basis for creating a model for these small new information systems. Such sensor systems are called embedded systems in the technical sciences, and the authors want to couple it with general IS. They call the merger of these two important research areas (IS and embedded...... systems) for micro information systems (micro-IS). It is intended as a new research field within IS research. An initial framework model is established, which seeks to capture both the possibilities and constraints of this new paradigm, while looking simultaneously at the fundamental IS and ICT aspects...

  8. Tube plug

    International Nuclear Information System (INIS)

    Zafred, P. R.

    1985-01-01

    The tube plug comprises a one piece mechanical plug having one open end and one closed end which is capable of being inserted in a heat exchange tube and internally expanded into contact with the inside surface of the heat exchange tube for preventing flow of a coolant through the heat exchange tube. The tube plug also comprises a groove extending around the outside circumference thereof which has an elastomeric material disposed in the groove for enhancing the seal between the tube plug and the tube

  9. Ultrasonic inspection of tube to tube plate welds

    International Nuclear Information System (INIS)

    Telford, D.W.; Peat, T.S.

    1985-01-01

    To monitor the deterioration of a weld between a tube and tube plate which has been repaired by a repair sleeve inside the tube and brazed at one end to the tube, ultrasound from a crystal at the end of a rod is launched, in the form of Lamb-type waves, into the tube through the braze and allowed to travel along the tube to the weld and be reflected back along the tube. The technique may also be used for the type of heat exchanger in which, during construction, the tubes are welded to the tube plate via external sleeves in which case the ultrasound is used in a similar manner to inspect the sleeve/tube plate weld. an electromagnetic transducer may be used to generate the ultrasound. The ultrasonic head comprising the crystal and an acoustic baffle is mounted on a Perspex (RTM) rod which may be rotated by a stepping motor. Echo signals from the region of deterioration may be isolated by use of a time gate in the receiver. The device primarily detects circumferentially orientated cracks, and may be used in heat exchangers in nuclear power plants. (author)

  10. Risk factors for tube exposure as a late complication of glaucoma drainage implant surgery

    Directory of Open Access Journals (Sweden)

    Chaku M

    2016-03-01

    Full Text Available Meenakshi Chaku,1 Peter A Netland,2 Kyoko Ishida,3 Douglas J Rhee4 1Department of Ophthalmology, Loyola University Chicago, Maywood, IL, 2Department of Ophthalmology, University of Virginia School of Medicine, Charlottesville, VA, USA; 3Department of Ophthalmology, Toho University, Tokyo, Japan; 4Department of Ophthalmology and Visual Sciences, Case Western Reserve University, Cleveland, OH, USA Purpose: The purpose of this study was to evaluate the risk factors for tube exposure after glaucoma drainage implant surgery.Patients and methods: This was a retrospective case-controlled observational study of 64 eyes from 64 patients. Thirty-two eyes of 32 patients with tube erosion requiring surgical revision were compared with 32 matched control eyes of 32 patients. Univariate and multivariate risk factor analyses were performed.Results: Mean age was significantly younger in the tube exposure group compared with the control group (48.2±28.1 years versus 67.3±18.0 years, respectively; P=0.003. The proportion of diabetic patients (12.5% in the tube exposure group was significantly less (P=0.041 compared with the control group (37.5%. Comparisons of the type and position of the drainage implant were not significantly different between the two groups. The average time to tube exposure was 17.2±18.0 months after implantation of the drainage device. In both univariate and multivariate analyses, younger age (P=0.005 and P=0.027 and inflammation prior to tube exposure (P≤0.001 and P=0.004 were significant risk factors. Diabetes was a significant risk factor only in the univariate analysis (P=0.027.Conclusion: Younger age and inflammation were significant risk factors for tube exposure after drainage implant surgery. Keywords: glaucoma drainage implant complications, Ahmed Glaucoma Valve, Baerveldt implant, tube erosion, pericardial patch graft

  11. MicroED data collection and processing

    Energy Technology Data Exchange (ETDEWEB)

    Hattne, Johan; Reyes, Francis E.; Nannenga, Brent L.; Shi, Dan; Cruz, M. Jason de la [Janelia Research Campus, Howard Hughes Medical Institute, Ashburn, VA 20147 (United States); Leslie, Andrew G. W. [Medical Research Council Laboratory of Molecular Biology, Cambridge (United Kingdom); Gonen, Tamir, E-mail: gonent@janelia.hhmi.org [Janelia Research Campus, Howard Hughes Medical Institute, Ashburn, VA 20147 (United States)

    2015-07-01

    The collection and processing of MicroED data are presented. MicroED, a method at the intersection of X-ray crystallography and electron cryo-microscopy, has rapidly progressed by exploiting advances in both fields and has already been successfully employed to determine the atomic structures of several proteins from sub-micron-sized, three-dimensional crystals. A major limiting factor in X-ray crystallography is the requirement for large and well ordered crystals. By permitting electron diffraction patterns to be collected from much smaller crystals, or even single well ordered domains of large crystals composed of several small mosaic blocks, MicroED has the potential to overcome the limiting size requirement and enable structural studies on difficult-to-crystallize samples. This communication details the steps for sample preparation, data collection and reduction necessary to obtain refined, high-resolution, three-dimensional models by MicroED, and presents some of its unique challenges.

  12. Effectiveness of rosiglitazone on bleomycin-induced lung fibrosis: Assessed by micro-computed tomography and pathologic scores

    International Nuclear Information System (INIS)

    Jin, Gong Yong; Bok, Se Mi; Han, Young Min; Chung, Myung Ja; Yoon, Kwon-Ha; Kim, So Ri; Lee, Yong Chul

    2012-01-01

    Peroxisome proliferator-activated receptor-γ (PPARγ) agonists exhibit potent anti-fibrotic effects in the lung and other tissues. Recently, micro-computed tomography (CT) has been a useful tool for the investigation of lung diseases in small animals and is now increasingly applied to visualize and quantify the pulmonary structures. However, there is little information on the assessment for therapeutic effects of PPARγ agonists on the pulmonary fibrosis in mice using micro-CT. This study was aimed to determine the capability of micro-CT in examining the effects of rosiglitazone on pulmonary fibrosis. We used a murine model of bleomycin-induced lung fibrosis to evaluate the feasibility of micro-CT in evaluating the therapeutic potential of rosiglitazone on pulmonary fibrosis, comparing with pathologic scores. On micro-CT findings, ground glass opacity (80%) and consolidation (20%) were observed predominantly at 3 weeks after the instillation of bleomycin, and the radiologic features became more complex at 6 weeks. In bleomycin-instilled mice treated with rosiglitazone, the majority (80%) showed normal lung features on micro-CT. Radiological-pathologic correlation analyses revealed that ground glass opacity and consolidation were correlated closely with acute inflammation, while reticular opacity was well correlated with histological honeycomb appearance. These results demonstrate that rosiglitazone displays a protective effect on pulmonary fibrosis in mice and that the visualization of bleomycin-induced pulmonary fibrosis using micro-CT is satisfactory to assess the effects of rosiglitazone. It implies that micro-CT can be applied to evaluate therapeutic efficacies of a variety of candidate drugs for lung diseases.

  13. Effectiveness of rosiglitazone on bleomycin-induced lung fibrosis: Assessed by micro-computed tomography and pathologic scores

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Gong Yong; Bok, Se Mi; Han, Young Min [Department of Radiology, Chonbuk National University Medical School, Jeonju (Korea, Republic of); Chung, Myung Ja [Department of Pathology, Chonbuk National University Medical School, Jeonju (Korea, Republic of); Yoon, Kwon-Ha [Department of Radiology, Iksan Hospital, Iksan (Korea, Republic of); Kim, So Ri [Department of Internal Medicine and Research Center for Pulmonary Disorders, Chonbuk National University Medical School, Jeonju (Korea, Republic of); Lee, Yong Chul, E-mail: leeyc@jbnu.ac.kr [Department of Internal Medicine and Research Center for Pulmonary Disorders, Chonbuk National University Medical School, Jeonju (Korea, Republic of)

    2012-08-15

    Peroxisome proliferator-activated receptor-{gamma} (PPAR{gamma}) agonists exhibit potent anti-fibrotic effects in the lung and other tissues. Recently, micro-computed tomography (CT) has been a useful tool for the investigation of lung diseases in small animals and is now increasingly applied to visualize and quantify the pulmonary structures. However, there is little information on the assessment for therapeutic effects of PPAR{gamma} agonists on the pulmonary fibrosis in mice using micro-CT. This study was aimed to determine the capability of micro-CT in examining the effects of rosiglitazone on pulmonary fibrosis. We used a murine model of bleomycin-induced lung fibrosis to evaluate the feasibility of micro-CT in evaluating the therapeutic potential of rosiglitazone on pulmonary fibrosis, comparing with pathologic scores. On micro-CT findings, ground glass opacity (80%) and consolidation (20%) were observed predominantly at 3 weeks after the instillation of bleomycin, and the radiologic features became more complex at 6 weeks. In bleomycin-instilled mice treated with rosiglitazone, the majority (80%) showed normal lung features on micro-CT. Radiological-pathologic correlation analyses revealed that ground glass opacity and consolidation were correlated closely with acute inflammation, while reticular opacity was well correlated with histological honeycomb appearance. These results demonstrate that rosiglitazone displays a protective effect on pulmonary fibrosis in mice and that the visualization of bleomycin-induced pulmonary fibrosis using micro-CT is satisfactory to assess the effects of rosiglitazone. It implies that micro-CT can be applied to evaluate therapeutic efficacies of a variety of candidate drugs for lung diseases.

  14. Technical Design Report for the: PANDA Straw Tube Tracker

    CERN Document Server

    Erni, W; Krusche, B; Steinacher, M; Heng, Y; Liu, Z; Liu, H; Shen, X; Wang, Q; Xu, H; Aab, A; Albrecht, M; Becker, J; Csapó, A; Feldbauer, F; Fink, M; Friedel, P; Heinsius, F H; Held, T; Klask, L; Koch, H; Kopf, B; Leiber, S; Leyhe, M; Motzko, C; Pelizäus, M; Pychy, J; Roth, B; Schröder, T; Schulze, J; Sowa, C; Steinke, M; Trifterer, T; Wiedner, U; Zhong, J; Beck, R; Bianco, S; Brinkmann, K T; Hammann, C; Hinterberger, F; Kaiser, D; Kliemt, R; Kube, M; Pitka, A; Quagli, T; Schmidt, C; Schmitz, R; Schnell, R; Thoma, U; Vlasov, P; Walther, D; Wendel, C; Würschig, T; Zaunick, H G; Bianconi, A; Bragadireanu, M; Caprini, M; Pantea, D; Pantelica, D; Pietreanu, D; Serbina, L; Tarta, P D; Kaplan, D; Fiutowski, T; Idzik, M; Mindur, B; Przyborowski, D; Swientek, K; Czech, B; Kistryn, M; Kliczewski, S; Kozela, A; Kulessa, P; Lebiedowicz, P; Pysz, K; Schäfer, W; Siudak, R; Szczurek\\inst, A; Jowzaee, S; Kajetanowicz, M; Kamys, B; Kistryn, S; Korcyl, G; Korcyl, K; Krzemien, W; Magiera, A; Moskal, P; Palka, M; Rudy, Z; Salabura, P; Smyrski, J; Wrońska\\inst, A; Al-Turany, M; Arora, R; Augustin, I; Deppe, H; Flemming, H; Gerhardt, A; Götzen, K; Jordi, A F; Kalicy, G; Karabowicz, R; Lehmann, D; Lewandowski, B; Lühning, J; Maas, F; Orth, H; Patsyuk, M; Peters, K; Saito, T; Schepers, G; Schmidt, C J; Schmitt, L; Schwarz, C; Schwiening, J; Traxler, M; Voss, B; Wieczorek, P; Wilms, A; Zühlsdorf\\inst, M; Abazov, V M; Alexeev, G; Arefiev, A; Astakhov, V I; Barabanov, M Yu; Batyunya, B V; Davydov, Yu I; Dodokhov, V Kh; Efremov, A A; Fedunov, A G; Festchenko, A A; Galoyan, A S; Grigoryan, S; Karmokov, A; Koshurnikov, E K; Lobanov, V I; Lobanov, Yu Yu; Makarov, A F; Malinina, L V; Malyshev, V L; Mustafaev, G A; Olshevskiy, A; Pasyuk, M A; Perevalova, E A; Piskun, A A; Pocheptsov, T A; Pontecorvo, G; Rodionov, V K; Rogov, Yu N; Salmin, R A; Samartsev, A G; Sapozhnikov, M G; Shabratova, G S; Skachkova, A N; Skachkov, N B; Strokovsky, E A; Suleimanov, M K; Teshev, R Sh; Tokmenin, V V; Uzhinsky, V V; Vodopyanov, A S; Zaporozhets, S A; Zhuravlev, N I; Zorin, A G; Branford, D; Glazier, D; Watts, D; Woods, P; Britting, A; Eyrich, W; Lehmann, A; Uhlig, F; Dobbs, S; Metreveli, Z; Seth, K; Tomaradze, A; Xiao, T; Bettoni, D; Carassiti, V; Ramusino, A Cotta; Dalpiaz, P; Drago, A; Fioravanti, E; Garzia, I; Savriè, M; Stancari, G; Bianchi, N; Gianotti, P; Guaraldo, C; Lucherini, V; Orecchini, D; Pace, E; Bersani, A; Bracco, G; Macri, M; Parodi, R F; Bremer, D; Dormenev, V; Drexler, P; Düren, M; Eissner, T; Föhl, K; Galuska, M; Gessler, T; Hayrapetyan, A; Hu, J; Koch, P; Kröck, B; Kühn, W; Lange, S; Liang, Y; Merle, O; Metag, V; Moritz, M; Münchow, D; Nanova, M; Novotny, R; Spruck, B; Stenzel, H; Ullrich, T; Werner, M; Xu, H; Euan, C; Hoek, M; Ireland, D; Keri, T; Montgomery, R; Protopopescu, D; Rosner, G; Seitz, B; Babai, M; Glazenborg-Kluttig, A; Kavatsyuk, M; Lemmens, P; Lindemulder, M; Löhner, H; Messchendorp, J; Moeini, H; Schakel, P; Schreuder, F; Smit, H; Tambave, G; Weele, J C van der; Veenstra\\inst, R; Sohlbach, H; Büscher, M; Deermann, D; Dosdall, R; Esch, S; Gillitzer, A; Goldenbaum, F; Grunwald, D; Henssler, S; Herten, A; Hu, Q; Kemmerling, G; Kleines, H; Kozlov, V; Lehrach, A; Maier, R; Mertens, M; Ohm, H; Orfanitski, S; Prasuhn, D; Randriamalala, T; Ritman, J; Schadmand, S; Serdyuk, V; Sterzenbach, G; Stockmanns, T; Wintz, P; Wüstner, P; Xu, H; Kisiel, J; Li, S; Li, Z; Sun, Z; Xu, H; Rigato, V; Fissum, S; Hansen, K; Isaksson, L; Lundin, M; Schröder, B; Achenbach, P; Bleser, S; Cahit, U; Cardinali, M; Denig, A; Distler, M; Fritsch, M; Kangh, D; Karavdina, A; Lauth, W; Merkel, H; Michel, M; Espi, M C Mora; Müller, U; Pochodzalla, J; Prometeusz, J; Sanchez, S; Sanchez-Lorente, A; Schlimme, S; Sfienti, C; Weber\\inst, M Thiel T; Dormenev, V I; Fedorov, A A; Korzhik, M V; Missevitch, O V; Balanutsa, V; Chernetsky, V; Demekhin, A; Dolgolenko, A; Fedorets, P; Gerasimov, A; Goryachev, V; Varentsov, V; Boukharov, A; Malyshev, O; Marishev, I; Semenov, A; Böhmer, F; Dørheim, S; Ketzer, B; Paul, S; Hergemöller, A K; Khoukaz, A; Köhler, E; Täschner, A; Wessels, J; Varma, R; Chaterjee, A; Jha, V; Kailas, S; Roy, B; Yan, Y; Chinorat, K; Khanchai, K; Ayut, L; Pomrad, S; Baldin, E; Kotov, K; Peleganchuk, S; Tikhonov, Yu; Boucher, J; Chambert, V; Dbeyssi, A; Hennino, T; Imre, M; Kunne, R; Galliard, C Le; Ma, B; Marchand, D; Maroni, A; Ong, S; Ramstein, B; Rosier, P; Sudol, M; Tomasi-Gustafsson, E; Wiele, J Van de; Boca, G; Braghieri, A; Costanza, S; Genova, P; Lavezzi, L; Montagna, P; Rotondi, A; Abramov, V; Belikov, N; Davidenko, A; Derevschikov, A; Goncharenko, Y; Grishin, V; Kachanov, V; Konstantinov, D; Kormilitsin, V; Melnik, Y; Levin, A; Minaev, N; Mochalov, V; Morozov, D; Nogach, L; Poslavskiy, S; Ryazantsev, A; Ryzhikov, S; Semenov, P; Shein, I; Uzunian, A; Vasiliev, A; Yakutin, A; Bäck, T; Cederwall, B; Makónyi, K; Tegnér, P E; Würtemberg, K M von; Belostotski, S; Gavrilov, G; Itzotov, A; Kashchuk, A; Kisselev, A; Kravchenko, P; Levitskaya, O; Manaenkov, S; Miklukho, O; Naryshkin, Y; Veretennikov, D; Vikhrov, V; Zhadanov, A; Alberto, D; Amoroso, A; Bussa, M P; Busso, L; Mori, F De; Destefanis, M; Fava, L; Ferrero, L; Greco, M; Maggiora, M; Marcello, S; Sosio, S; Spataro, S; Zotti, L; Calvo, D; Coli, S; Remigis, P De; Filippi, A; Giraudo, G; Lusso, S; Mazza, G; Morra, O; Rivetti, A; Wheadon, R; Iazzi, F; Lavagno, A; Younis, H; Birsa, R; Bradamante, F; Bressan, A; Martin, A; Clement, H; Galander, B; Balkestal, L Caldeira; Calén, H; Fransson, K; Johansson, T; Kupsc, A; Marciniewski, P; Thomé, E; Wolke, M; Zlomanczuk, J; Díaz, J; Ortiz, A; Dmowski, K; Korzeniewski, R; Przemyslaw, D; Slowinski, B; Chlopik, A; Guzik, Z; Kosinski, K; Melnychuk, D; Wasilewski, A; Wojciechowski, M; Wronka, S; Wysocka, A; Zwieglinski, B; Bühler, P; Hartman, O; Kienle, P; Marton, J; Suzuki, K; Widmann, E; Zmeskal, J

    2012-01-01

    This document describes the technical layout and the expected performance of the Straw Tube Tracker (STT), the main tracking detector of the PANDA target spectrometer. The STT encloses a Micro-Vertex-Detector (MVD) for the inner tracking and is followed in beam direction by a set of GEM-stations. The tasks of the STT are the measurement of the particle momentum from the reconstructed trajectory and the measurement of the specific energy-loss for a particle identification. Dedicated simulations with full analysis studies of certain proton-antiproton reactions, identified as being benchmark tests for the whole \\Panda scientific program, have been performed to test the STT layout and performance. The results are presented, and the time lines to construct the STT are described.

  15. Aerial Object Following Using Visual Fuzzy Servoing

    OpenAIRE

    Olivares Méndez, Miguel Ángel; Mondragon Bernal, Ivan Fernando; Campoy Cervera, Pascual; Mejias Alvarez, Luis; Martínez Luna, Carol Viviana

    2011-01-01

    This article presents a visual servoing system to follow a 3D moving object by a Micro Unmanned Aerial Vehicle (MUAV). The presented control strategy is based only on the visual information given by an adaptive tracking method based on the color information. A visual fuzzy system has been developed for servoing the camera situated on a rotary wing MAUV, that also considers its own dynamics. This system is focused on continuously following of an aerial moving target object, maintai...

  16. Draft tube flow phenomena across the bulb turbine hill chart

    International Nuclear Information System (INIS)

    Duquesne, P; Fraser, R; Maciel, Y; Aeschlimann, V; Deschênes, C

    2014-01-01

    In the framework of the BulbT project launched by the Consortium on Hydraulic Machines and the LAMH (Hydraulic Machine Laboratory of Laval University) in 2011, an intensive campaign to identify flow phenomena in the draft tube of a model bulb turbine has been done. A special focus was put on the draft tube component since it has a particular importance for recuperation in low head turbines. Particular operating points were chosen to analyse flow phenomena in this component. For each of these operating points, power, efficiency and pressure were measured following the IEC 60193 standard. Visualizations, unsteady wall pressure and efficiency measurements were performed in this component. The unsteady wall pressure was monitored at seven locations in the draft tube. The frequency content of each pressure signal was analyzed in order to characterize the flow phenomena across the efficiency hill chart. Visualizations were recorded with a high speed camera using tufts and cavitation bubbles as markers. The predominant detected phenomena were mapped and categorized in relation to the efficiency hill charts obtained for three runner blade openings. At partial load, the vortex rope was detected and characterized. An inflection in the partial load efficiency curves was found to be related to complex vortex rope instabilities. For overload conditions, the efficiency curves present a sharp drop after the best efficiency point, corresponding to an inflection on the power curves. This break off is more severe towards the highest blade openings. It is correlated to a flow separation at the wall of the draft tube. Also, due to the separation occurring in these conditions, a hysteresis effect was observed on the efficiency curves

  17. Percutaneous nephrolithotomy with or without nephrostomy tube

    Directory of Open Access Journals (Sweden)

    Mohammed Aulad Hossain

    2018-05-01

    Full Text Available The study has been designed to compare the outcome of percutaneous nephrolithotomy with (Group A or without nephrostomy tube (Group B for the management of renal stone disease. JJ stents were given to all cases of both groups. Comparison of outcome between groups shows that urinary leakage time was significantly longer in Group B than that in Group A (24.0 ± 6.2 vs 7.3 ± 3.9 hours;  p<0.001. Visual analogue pain score was also significantly high in Group B than in Group A (4.7 ± 0.8 vs 2.4 ± 0.5; p<0.035. Patients in Group B stayed in hospital on an average 4 days, while the Group A patients stayed in hospital on an average 2.5 days (p<0.029. The mean hemoglobin decrease in 24 hours in Group B and in Group A (0.5 ± 0.4 and 0.5 ± 0.4 respectively did not show any significant difference (p<0.895. In conclusion, percutaneous nephrolithotomy without nephrostomy tube can be practiced in the management of selective cases of renal stones diseases.

  18. Effects of tube potential and scatter rejection on image quality and effective dose in digital chest X-ray examination: An anthropomorphic phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Shaw, D.J., E-mail: daniel.shaw@christie.nhs.uk [Diagnostic Radiology, Department of Medical Physics and Engineering, Leeds Teaching Hospitals, Leeds General Infirmary, Great George Street, Leeds LS1 3EX (United Kingdom); Crawshaw, I. [Diagnostic X-ray Department, York Teaching Hospital NHS Foundation Trust, The York Hospital, Wigginton Road, York YO31 8HE (United Kingdom); Rimmer, S. D. [Diagnostic Radiology, Department of Medical Physics and Engineering, Leeds Teaching Hospitals, Leeds General Infirmary, Great George Street, Leeds LS1 3EX (United Kingdom)

    2013-11-15

    Objectives: The purpose of this study was to investigate the effects of tube potential and scatter rejection techniques on image quality of digital posteroanterior (PA) chest radiographs. Methods: An anthropomorphic phantom was imaged using a range of tube potentials (81–125 kV{sub p}) without scatter rejection, with an anti-scatter grid, and using a 10 cm air gap. Images were anonymised and randomised before being evaluated using a visual graded analysis (VGA) method. Results: The effects of tube potential on image quality were found to be negligible (p > 0.63) for the flat panel detector (FPD). Decreased image quality (p = 0.031) was noted for 125 kV{sub p} relative to 109 kV{sub p}, though no difference was noted for any of the other potentials (p > 0.398) for computed radiography (CR). Both scatter rejection techniques improved image quality (p < 0.01). For FPD imaging the anti-scatter grid offered slightly improved image quality relative to the air gap (p = 0.038) but this was not seen for CR (p = 0.404). Conclusions: For FPD chest imaging of the anthropomorphic phantom there was no dependence of image quality on tube potential. Scatter rejection improved image quality, with the anti-scatter grid giving greater improvements than an air-gap, but at the expense of increased effective dose. CR imaging of the chest phantom demonstrated negligible dependence on tube potential except at 125 kV{sub p}. Scatter rejection improved image quality, but with no difference found between techniques. The air-gap resulted in a smaller increase in effective dose than the anti-scatter grid and would be the preferred scatter rejection technique.

  19. Experimental study of micro dimple fabrication based on laser shock processing

    Science.gov (United States)

    Li, Kangmei; Hu, Yongxiang; Yao, Zhenqiang

    2013-06-01

    Micro-dimple array has been generally considered as a valuable texture for sliding surfaces. It can improve lubrication and reduce wear by acting as reservoirs of lubricants and grinding debris. Laser shock processing (LSP) is an innovative process which can not only improve fatigue, corrosion and wearing resistance but also shape metallic parts accurately. In this study, a new process for the fabrication of micro dimples based on LSP was proposed, which was named as laser peen texturing (LPT). Experiments were performed on 2024 aluminum alloy, Oxygen-Free High Conductivity (OFHC) copper and SUS304 stainless steel to study the effects of processing parameters of LPT on surface integrity of the specimen. Surface morphology, micro hardness and microstructure of the micro dimples were investigated under various laser power densities, laser spot diameters and repeated shock numbers. It was found that the depth of the micro dimples induced by LPT is strongly dependent on material properties. The diameter, depth as well as aspect ratio of micro dimples were increased with the laser power density and the repeated shock number under the conditions in this study. But when the laser spot diameter changed, the variation laws of the diameter, depth and aspect ratio of the dimple were different from each other. The results of micro hardness measurements suggested that LPT is beneficial for the improvement of the micro hardness beneath the dimple. Grain refinement was found significantly on 2024 aluminum alloy and OFHC copper but not clearly on SUS304 stainless steel. Both the hardening effect and the grain refinement have close relationship with the depth of the micro dimple.

  20. Innovative Application of a Microlaryngeal Surgery Tube for difficult Airway Management in a Case of Down's Syndrome.

    Science.gov (United States)

    Gulabani, Michell; Gupta, Akhilesh; Bannerjee, Neerja Gaur; Sood, Rajesh; Dass, Prashant

    2016-04-01

    An 11-year-old male child, known case of down's syndrome with congenital oesophageal stricture was posted for oesophageal dilatation. Preoperative airway assessment revealed a high arched palate, receding mandible and Mallampati Score of 2. During surgery, after loss of consciousness which was described as loss of eyelash reflex and adequate jaw relaxation, direct laryngoscopy and endotracheal intubation was attempted with a cuffed endotracheal tube number 5.0mm ID (internal diameter). The endotracheal tube could not be negotiated smoothly, so 5.0mm ID uncuffed endotracheal tube was used which passed through easily, but on auscultation revealed a significant leak. Later, intubation via a Micro Laryngeal Surgery (MLS) cuffed tube 4.0mm ID was attempted. The MLS tube advanced smoothly and there was no associated leak on positive pressure ventilation. Thus by innovative thinking and avant-garde reasoning, a definitive airway device could be positioned with no other suitable alternative at hand.

  1. Heat transfer and flow characteristics around a finned-tube bank heat exchanger in fluidized bed

    International Nuclear Information System (INIS)

    Honda, Ryosuke; Umekawa, Hisashi; Ozawa, Mamoru

    2009-01-01

    Principal heat transfer mechanisms in a fluidized bed have been classified into three categories, i.e. solid convection, gas convection and radiation. Among these mechanisms, the solid convection is a dominant mechanism in the bubbling fluidized bed. This solid convection is substantially caused by the bubble movement, thus the visualization of the void fraction distribution becomes a very useful method to understand the characteristics of the fluidized-bed heat exchanger. In this study, the heat transfer coefficient and the void fraction around the heat transfer tube with annuler fin were measured. For the quantitative measurement of the void fraction, neutron radiography and image processing technique were employed. Owing to the existence of the annuler fin, the restriction of the particle movements was put. This restriction suppressed the disturbance caused by tubes, and the influence of the tube arrangement on the flow and heat transfer characteristics could be clearly expressed.

  2. Heat transfer and flow characteristics around a finned-tube bank heat exchanger in fluidized bed

    Energy Technology Data Exchange (ETDEWEB)

    Honda, Ryosuke [Department of Mechanical Engineering, Kansai University, 3-3-35 Yamate-cho, Suita, Osaka 564-8680 (Japan); Umekawa, Hisashi [Department of Mechanical Engineering, Kansai University, 3-3-35 Yamate-cho, Suita, Osaka 564-8680 (Japan)], E-mail: umekawa@kansai-uac.jp; Ozawa, Mamoru [Department of Mechanical Engineering, Kansai University, 3-3-35 Yamate-cho, Suita, Osaka 564-8680 (Japan)

    2009-06-21

    Principal heat transfer mechanisms in a fluidized bed have been classified into three categories, i.e. solid convection, gas convection and radiation. Among these mechanisms, the solid convection is a dominant mechanism in the bubbling fluidized bed. This solid convection is substantially caused by the bubble movement, thus the visualization of the void fraction distribution becomes a very useful method to understand the characteristics of the fluidized-bed heat exchanger. In this study, the heat transfer coefficient and the void fraction around the heat transfer tube with annuler fin were measured. For the quantitative measurement of the void fraction, neutron radiography and image processing technique were employed. Owing to the existence of the annuler fin, the restriction of the particle movements was put. This restriction suppressed the disturbance caused by tubes, and the influence of the tube arrangement on the flow and heat transfer characteristics could be clearly expressed.

  3. Some mechanisms for the formation of octopus-shaped iron micro-particles

    International Nuclear Information System (INIS)

    Bica, Ioan

    2004-01-01

    Fluid spheres (micro-spheres or/and drops) are formed out of the metallic solid (the carbon steel semi-finished product) in the argon plasma of the transferred electric arc. For short intervals of time, the spheres are at rest with relation to vapors. The movement of the vapors around the spheres is in the same plane. It consists of a movement around a circle combined with the movement produced by a definitely located whirl. The molar concentration of the vapors is small in comparison with the molar density of the mixture formed of vapors and gas. At the intersection of the sphere and the plane of movement of the vapors, distinct stagnation point is formed. They constitute points of the beginning/and end of the current lines. Each current line is a carrier of a vapor cylinder. In time, the cylinder-gas interface reaches points of temperature equal to that of the 'dew point' for iron. On this occasion a liquid membrane is formed. It delimits the vapor-gas mixture from the rest of the gas. Subsequent to the process of diffusion in non-stationary condition, the membrane becomes thicker and no vapors exist inside the tube. Needle-shaped micro-tubes are formed, in liquid phase, around the fluid sphere. By solidification, micro-particles occur, consisting of a central nucleus around which ligaments branch out

  4. Some mechanisms for the formation of octopus-shaped iron micro-particles

    Energy Technology Data Exchange (ETDEWEB)

    Bica, Ioan E-mail: ibica2@yahoo.com

    2004-08-01

    Fluid spheres (micro-spheres or/and drops) are formed out of the metallic solid (the carbon steel semi-finished product) in the argon plasma of the transferred electric arc. For short intervals of time, the spheres are at rest with relation to vapors. The movement of the vapors around the spheres is in the same plane. It consists of a movement around a circle combined with the movement produced by a definitely located whirl. The molar concentration of the vapors is small in comparison with the molar density of the mixture formed of vapors and gas. At the intersection of the sphere and the plane of movement of the vapors, distinct stagnation point is formed. They constitute points of the beginning/and end of the current lines. Each current line is a carrier of a vapor cylinder. In time, the cylinder-gas interface reaches points of temperature equal to that of the 'dew point' for iron. On this occasion a liquid membrane is formed. It delimits the vapor-gas mixture from the rest of the gas. Subsequent to the process of diffusion in non-stationary condition, the membrane becomes thicker and no vapors exist inside the tube. Needle-shaped micro-tubes are formed, in liquid phase, around the fluid sphere. By solidification, micro-particles occur, consisting of a central nucleus around which ligaments branch out.

  5. Some mechanisms for the formation of octopus-shaped iron micro-particles

    Science.gov (United States)

    Bica, Ioan

    2004-08-01

    Fluid spheres (micro-spheres or/and drops) are formed out of the metallic solid (the carbon steel semi-finished product) in the argon plasma of the transferred electric arc. For short intervals of time, the spheres are at rest with relation to vapors. The movement of the vapors around the spheres is in the same plane. It consists of a movement around a circle combined with the movement produced by a definitely located whirl. The molar concentration of the vapors is small in comparison with the molar density of the mixture formed of vapors and gas. At the intersection of the sphere and the plane of movement of the vapors, distinct stagnation point is formed. They constitute points of the beginning/and end of the current lines. Each current line is a carrier of a vapor cylinder. In time, the cylinder-gas interface reaches points of temperature equal to that of the "dew point" for iron. On this occasion a liquid membrane is formed. It delimits the vapor-gas mixture from the rest of the gas. Subsequent to the process of diffusion in non-stationary condition, the membrane becomes thicker and no vapors exist inside the tube. Needle-shaped micro-tubes are formed, in liquid phase, around the fluid sphere. By solidification, micro-particles occur, consisting of a central nucleus around which ligaments branch out.

  6. Development of heat treated Zr-2.5 Wt% Nb pressure tube and its microstructural characterization using electron microscopy techniques

    International Nuclear Information System (INIS)

    Saibaba, N.

    2010-01-01

    Two phase Zr-2.5 wt % Nb alloy is widely used for manufacture of pressure tubes for pressurized heavy water reactors (PHWRs). These tubes are used in cold worked and stress relieved (CWSRs) condition and are manufactured by cold drawing or pilgering routes. The microstructure of the CWSR tube is characterized with presence of discontinuous β phase stringers sandwiched between elongated α-phase. Pressure tube undergoes dimensional changes and micro structural deterioration under the reactor operating conditions of temperature, pressure and neutron flux. This limits the life of the component and the availability of the power reactors. There is renewed interest in increasing the life of the pressure tube by bringing about a change in the microstructure of Zr-2.5 Nb material using various thermo mechanical processes during its manufacturing. Heat treatment of this two-phase alloy has been understood to uniquely stabilize the microstructure, which prevents degradation, under in-reactor service condition. This paper illustrates various heat treatment cycles carried out at intermediate cold working stage. Heat treatment involves solutionization of the Zr-2.5 wt % Nb tube from different temperatures followed by two types of quenching process viz, gas quenching and water quenching. The OIM-TEM studies were carried out for characterization of final tube. The technique confirmed the presence of β-phase relatively enriched in Nb content. The resulting SEM microstructures after ageing treatment at different soaking temperatures and time have been presented. Mechanical properties of heat treated pressure tubes, both at room temperature and elevated temperature have been compared with conventional CWSR pressure tube used in PHWRs. (author)

  7. Teachers' Use of YouTube in the United Arab Emirates: An Exploratory Study

    Science.gov (United States)

    Tamim, Rana M.

    2013-01-01

    Teachers around the world are using YouTube movies for different purposes. This mixed-methods study was a preliminary investigation of United Arab Emirates teachers' perceptions about YouTube's advantages in the classroom, current practices, and major challenges faced. Forty-five teachers completed an open-ended questionnaire. Results indicated…

  8. Tube spacer grid for a heat-exchanger tube bundle

    International Nuclear Information System (INIS)

    Scheidl, H.

    1976-01-01

    A tube spacer grid for a heat-exchanger tube bundle is formed by an annular grid frame having a groove formed in its inner surface in which the interspaced grid bars have their ends positioned and held in interspaced relationship by short sections of tubes passed through holes axially formed in the grid frame so that the tubes are positioned between the ends of the grid bars in the grooves. The tube sections may be cut from the same tubes used to form the tube bundle. 5 claims, 3 drawing figures

  9. Study of tube diameter effect on the burnout

    International Nuclear Information System (INIS)

    Levitan, L.L.; Lantsman, F.P.; Dedneva, E.I.

    1981-01-01

    Effect of a tube diameter d on boundary steam content Xsub(b) is experimentally investigated during unwashed liquid wall film drying in the disperse-ring flow regime. For this purpose systematical experimental investigations of the burnout of the second kind in tubes with diameters of 4, 6 and 12 mm have been carried out as well as the other data relating to burnout in tubes with diameter from 4 to 40 mm are used. The investigations have been carried out at water and steam pressures of 4.9-13.7 MPa and mass velocities from 750 to 5000 kg/m 2 xs. It is elucidated that increase in the tube diameter results in reducing the ranges of pressures and mass velocities at which Xsub(b) is independent of heat flux. Quantity dependence Xsub(b)=f(d) has been obtained as well. The best agreement with data from different experiments is observed when taking into account the effect of d on Xsub(b) by means of the following relation: Xsub(b) is proportional to dsup(-0.25). In this case divergence, as a rule, does not exceed 10% [ru

  10. What monitor can replace the cathode-ray tube for visual stimulation to elicit multifocal electroretinograms?

    Science.gov (United States)

    Matsumoto, Celso Soiti; Shinoda, Kei; Matsumoto, Harue; Seki, Keisuke; Nagasaka, Eiichiro; Iwata, Takeshi; Mizota, Atsushi

    2014-08-05

    To compare a conventional cathode-ray tube (CRT) screen to organic light-emitting diode (OLED) and liquid crystal display (LCD) screens as visual stimulators to elicit multifocal electroretinograms (mfERGs), mfERGs were recorded from seven eyes of seven healthy volunteers (21 ± 2 years). The mfERGs elicited by a conventional CRT screen (S710, Compaq Computer Co.) were compared to those elicited by a studio-grade master OLED monitor (PVM-1741, Sony, Japan) and a conventional LCD (S1721, Flexscan, Eizo Nanao Corp., Japan). The luminance changes of each monitor were measured with a photodiode. CRT, OLED, and LCD screens with a frame frequency of 60 Hz were studied. A hexagonal stimulus array with 61 stimulus elements was created on each monitor. The serial white stimuli of the OLED screen at 60 Hz did not fuse, and that of the LCD screens fused. The amplitudes of P1 and P2 of the first-order kernels of the mfERGs were not significantly different from those elicited by the CRT and OLED screens, and the P1 amplitude of the first-order kernel elicited by the LCD stimuli was significantly smaller than that elicited by the CRT in all the groups of the averaged hexagonal elements. The implicit times were approximately 10 ms longer in almost all components elicited by the LCD screen compared to those elicited by the CRT screen. The mfERGs elicited by monitors other than the CRT should be carefully interpreted, especially those elicited by LCD screens. The OLED had good performance, and we conclude that it can replace the CRT as a stimulator for mfERGs; however, a collection of normative data is recommended. © 2014 ARVO.

  11. Mass spectrometric studies of bimolecular reactions in a selected ion flow tube (SIFT)

    International Nuclear Information System (INIS)

    Shul, R.J.; Upschulte, B.L.; Passarella, R.; Keesee, R.G.; Castleman, A.W.

    1985-01-01

    The rate coefficients for a number of thermal energy charge transfer reactions have been obtained with a selected ion flow tube (SIFT). The reactions studied involve Ar + and Ar 2 + with a variety of neutral molecules including: O 2 , CS 2 , CO 2 , SO 2 , H 2 S, NH 3 , and SF 6 . Such reactions have been of long-standing interest in the field of gas-phase ion-molecule chemistry from both a practical and fundamental point of view. Consideration of charge transfer reactions as possible sources of chemical lasers and their role in ionospheric and interstellar chemistry account for much of the interest. Fundamentally, the mechanism involved in these reactions has yet to be definitively established. The consumption deposition of energy into internal modes and translational degrees of freedom in such reactions has also been a topic of considerable debate. The apparatus consists of five main components: an ion source, SIFT quadrupole, ion injector, flow tube, and a mass spectrometer detection system. Ions formed in a high pressure source leak into a SIFT quadrupole where they are mass selected. The primary ion of interest is then injected into the flow tube where reactions are studied. Once in the flow tube the ions are carried downstream by an inert buffer gas, either argon, nitrogen, or helium in the present study. Neutral reactant gas is added through a reactant gas inlet (RGI) at an appropriate location downstream in the flow tube, and allowed to react with the injected ions. Ions on the flow tube axis are sampled through a 1 mm orifice where they are mass analyzed by a second quadrupole mass spectrometer and detected with a channeltron electron multiplier

  12. Integrity Analysis of Damaged Steam Generator Tubes

    International Nuclear Information System (INIS)

    Stanic, D.

    1998-01-01

    Variety of degradation mechanisms affecting steam generator tubes makes steam generators as one of the critical components in the nuclear power plants. Depending of their nature, degradation mechanisms cause different types of damages. It requires performance of extensive integrity analysis in order to access various conditions of crack behavior under operating and accidental conditions. Development and application of advanced eddy current techniques for steam generator examination provide good characterization of found damages. Damage characteristics (shape, orientation and dimensions) may be defined and used for further evaluation of damage influence on tube integrity. In comparison with experimental and analytical methods, numerical methods are also efficient tools for integrity assessment. Application of finite element methods provides relatively simple modeling of different type of damages and simulation of various operating conditions. The stress and strain analysis may be performed for elastic and elasto-plastic state with good ability for visual presentation of results. Furthermore, the fracture mechanics parameters may be calculated. Results obtained by numerical analysis supplemented with experimental results are the base for definition of alternative plugging criteria which may significantly reduce the number of plugged tubes. (author)

  13. Effect of Tube Pitch on Pool Boiling Heat Transfer of Vertical Tube Bundle

    International Nuclear Information System (INIS)

    Kang, Myeong Gie

    2016-01-01

    Summarizing the previous results it can be stated that heat transfer coefficients are highly dependent on the tube pitch and the heat flux of the relevant tube. The published results are mostly about the horizontal tubes. However, there are many heat exchangers consisting of vertical tubes like AP600. Therefore, the focus of the present study is an identification of the effects of a tube pitch as well as the heat flux of a relevant tube on the heat transfer of a tube bundle installed vertically. When the heat flux is increased many bubbles are generating due to the increase of the nucleation sites. The bubbles become coalescing with the nearby bubbles and generates big bunches of bubbles on the tube surface. This prevents the access of the liquid to the surface and deteriorates heat transfer. The bubble coalescence is competing with the mechanisms enhancing heat transfer. The pitch was varied from 28.5 mm to 95 mm and the heat flux of the nearby tube was changed from 0 to 90kW/m"2. The enhancement of the heat transfer is clearly observed when the heat flux of the nearby tube becomes larger and the heat flux of the upper tube is less than 40kW/m"2. The effect of the tube pitch on heat transfer is negligible as the value of DP/ is increased more than 4.

  14. Simultaneous thermal and optical imaging of two-phase flow in a micro-model.

    Science.gov (United States)

    Karadimitriou, N K; Nuske, P; Kleingeld, P J; Hassanizadeh, S M; Helmig, R

    2014-07-21

    In the study of non-equilibrium heat transfer in multiphase flow in porous media, parameters and constitutive relations, like heat transfer coefficients between phases, are unknown. In order to study the temperature development of a relatively hot invading immiscible non-wetting fluid and, ultimately, approximate heat transfer coefficients, a transparent micro-model is used as an artificial porous medium. In the last few decades, micro-models have become popular experimental tools for two-phase flow studies. In this work, the design of an innovative, elongated, PDMS (polydimethylsiloxane) micro-model with dimensions of 14.4 × 39 mm(2) and a constant depth of 100 microns is described. A novel setup for simultaneous thermal and optical imaging of flow through the micro-model is presented. This is the first time that a closed flow cell like a micro-model is used in simultaneous thermal and optical flow imaging. The micro-model is visualized by a novel setup that allowed us to monitor and record the distribution of fluids throughout the length of the micro-model continuously and also record the thermal signature of the fluids. Dynamic drainage and imbibition experiments were conducted in order to obtain information about the heat exchange between the phases. In this paper the setup as well as analysis and qualitative results are presented.

  15. Hideout of sea water impurities in steam generator tube deposits: laboratory and field studies

    International Nuclear Information System (INIS)

    Balakrishnan, P.V.; Turner, C.W.; Thompson, R.; Sawochka, S.

    1996-01-01

    Sea water impurities hide out within thin (∼10 μm) deposits on steam generator tubes, as demonstrated by both laboratory studies using segments of fouled steam generator tubes pulled in 1992 from Crystal River-3 nuclear power station and field hideout return studies performed during recent plant shutdowns. Laboratory tests performed at 279 o C (534 o F) and heat fluxes ranging from 35 to 114 kW/m 2 (11,100 - 36,150 Btu/h.ft 2 ), conditions typical of the lower tubesheet to the first support plate region of a once-through steam generator, showed that impurity hideout can occur in thin free-span tube deposits. The extent of hideout increased with increasing heat flux. Soluble species, such as sodium and chloride ions, returned promptly to the bulk water from the deposits when the heat flux was turned off, whereas less soluble species, such as calcium sulfate and magnesium hydroxide, returned more slowly. Recent field hideout return studies performed at Crystal River-3 where the water level in the steam generators was maintained below the first tube support plate during the shutdown, thus wetting only the thin deposits in the free span and the small sludge pile, corroborate the laboratory findings, showing that hideout does indeed occur in the free-span regions of the tubes. These findings suggest that hideout within tube deposits has to be accounted for in the calculation of crevice chemistry from hideout return studies and in controlling the bulk chemistry using the molar ratio criterion. (author). 3 refs., 4 tabs., 3 figs

  16. Confirming nasogastric tube placement: Is the colorimeter as sensitive and specific as X-ray? A diagnostic accuracy study.

    Science.gov (United States)

    Mordiffi, Siti Zubaidah; Goh, Mien Li; Phua, Jason; Chan, Yiong-Huak

    2016-09-01

    The effect of delivering enteral nutrition or medications via a nasogastric tube that is inadvertently located in the tracheobronchial tract can cause respiratory complications. Although radiographic examination is accepted as the gold standard for confirming the position of patients' enteral tubes, it is costly, involves risks of radiation, and is not failsafe. Studies using carbon dioxide sensors to detect inadvertent nasogastric tube placements have been conducted in intensive care settings. However, none involved patients in general wards. The objective of this study was to ascertain the diagnostic measure of colorimeter, with radiographic examination as the reference standard, to confirm the location of nasogastric tubes in patients. A prospective observational study of a diagnostic test. This study was conducted in the general wards of an approximately 1100-bed acute care tertiary hospital of an Academic Medical Center in Singapore. Adult patients with nasogastric tubes admitted to the general wards were recruited into the study. The colorimeter was attached to the nasogastric tube to detect for the presence of carbon dioxide, suggestive of a tracheobronchial placement. The exact location of the nasogastric tube was subsequently confirmed by a radiographic examination. A total of 192 tests were undertaken. The colorimeter detected carbon dioxide in 29 tested nasogastric tubes, of which radiographic examination confirmed that four tubes were located in the tracheobronchial tract. The colorimeter failed to detect carbon dioxide in one nasogastric tube that was located in the tracheobronchial tract, thus, demonstrating a sensitivity of 0.80 [95% CI (0.376, 0.964)]. The colorimeter detected absence of carbon dioxide in 163 tested nasogastric tubes in which radiographic examination confirmed 160 gastrointestinal and one tracheobronchial placements, demonstrating a specificity of 0.865 [95% CI (0.808, 0.907)]. The colorimeter detected one tracheobronchial

  17. Flow Regime Destabilizing Effect on Fluid elastic Instability of Tube Array Preferentially Flexible to the Flow Direction

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kanghee; Shin, Changhwan [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Olala, Stephen; Mureithi, Njuki [BWC/AECL/NSERC Chair of Fluid-Structure Interaction, Ecole Polytechnique, Montreal (Canada)

    2015-05-15

    U bend region of operating SG is excited by the inclined cross flow due to the gradual change of hydraulic resistance force. The effect of tube array's flexibility direction on FEI is investigated by Khalvatti for rotated triangular tube in single phase (air) cross flow. He showed that FEI strongly depend on the flexibility angle. Reducing bundle flexibility to the flow direction ranging from 90 (out-of-flow direction) to 0 (in-flow direction) degree has a nonlinearly-varying stabilizing effect. Joly studies the same problem under high void fraction in two phase cross flow over 70 % to 90 %. With the Joly's experimental work, there is oddly low-valued Conner's constant in case of higher degree of angle of attack. This gives the motivation to our experimental study for fluid elastic instability of tube array in two phase cross flow. As the flow rate goes up, tube response was measured for each steady state flow condition by the strain gauge. Damping, peak frequency, and the critical velocity were estimated from the response spectrum. It seems that the flow regime for high void fraction can destabilize tube array with preferential flexibility over 60 degree. Because an intermittent flow is inherently unstable compared to the uniform bubbly flow, thus out-of-flow motion of tubes can be more fragile to the unstably rising intermittent flow. From the visual inspection, lateral tube motion seems to block the flow path periodically. Enlarged bubble in an intermittent flow regime can be squeezed-up at the flow gap between tubes.

  18. Development of heat treated Zr-2.5% Nb alloy tubes for pressure tubes

    International Nuclear Information System (INIS)

    Saibaba, N.; Jha, S.K.; Tonpe, S.

    2011-01-01

    Zr-2.5% Nb alloy is the candidate material for pressure tubes of Pressurized Heavy Water Reactors (PHWR), and are manufactured in cold working condition while heat treated pressure tubes are used in RBMK and FUGEN type of reactors. The diametral creep of these tubes is the life limiting factor. This paper presents the extensive work carried out for the optimization of process parameters to manufacture heat treated Zr-2.5% Nb pressure tubes. Extensive dilactometry study was carried out to establish the transus temperature for the alloy and the effect of soaking temperature and cooling rate on the microstructure was characterized. On the basis of the study, water quenching (at 883 deg C) in the a b region with 20-25% primary a phase was selected, further cold worked, aged and finally autoclaved. Mechanical properties of the finished tubes were found to be comparable to the cold worked route. Large number of full sized tubes of about 700 - 800 mm long was produced to establish the repeatability. (author)

  19. Study of scratch-induced stress corrosion cracking for steam generator tubes and scratch control

    International Nuclear Information System (INIS)

    Meng, F.; Xu, X.; Liu, X.; Wang, J.

    2014-01-01

    This paper introduces field cases for scratch-induced stress corrosion cracking (SISCC) of steam generator tubes in PWR and current studies in laboratories. According to analysis result of broke tubes, scratches caused intergranular stress corrosion cracking (IGSCC) with outburst. The effect of microstructure for nickel-base alloys, residual stresses caused by scratching process and water chemistry on SISCC and possible mechanism of SISCC are discussed. The result shows that scratch-induced microstructure evolution contributes to SISCC significantly. The causes of scratches during steam generator tubing manufacturing and installation process are stated and improved reliability with scratch control is highlighted for steam generator tubes in newly built nuclear power plants. (author)

  20. Study of scratch-induced stress corrosion cracking for steam generator tubes and scratch control

    Energy Technology Data Exchange (ETDEWEB)

    Meng, F.; Xu, X.; Liu, X. [Shanghai Nuclear Engineering Research and Design Institute, Shanghai (China); Wang, J. [Chinese Academy of Sciences, Institute of Metal Research, Shenyang (China)

    2014-07-01

    This paper introduces field cases for scratch-induced stress corrosion cracking (SISCC) of steam generator tubes in PWR and current studies in laboratories. According to analysis result of broke tubes, scratches caused intergranular stress corrosion cracking (IGSCC) with outburst. The effect of microstructure for nickel-base alloys, residual stresses caused by scratching process and water chemistry on SISCC and possible mechanism of SISCC are discussed. The result shows that scratch-induced microstructure evolution contributes to SISCC significantly. The causes of scratches during steam generator tubing manufacturing and installation process are stated and improved reliability with scratch control is highlighted for steam generator tubes in newly built nuclear power plants. (author)

  1. Small-bore chest tubes seem to perform better than larger tubes in treatment of spontaneous pneumothorax

    DEFF Research Database (Denmark)

    Iepsen, Ulrik Winning; Ringbæk, Thomas

    2013-01-01

    The aim of this study was to compare the efficacy and complications of surgical (large-bore) chest tube drainage with smaller and less invasive chest tubes in the treatment of non-traumatic pneumothorax (PT). ......The aim of this study was to compare the efficacy and complications of surgical (large-bore) chest tube drainage with smaller and less invasive chest tubes in the treatment of non-traumatic pneumothorax (PT). ...

  2. STUDY & ANALYSIS OF MICRO NEEDLE MATERIAL BY ANSYS

    OpenAIRE

    Santosh Kumar Singh*, Prabhat Sinha, N.N. Singh, Nagendra Kumar

    2017-01-01

    In this research the concept of design and analysis, silicon and stainless steel based on hollow micro-needles for transdermal drug delivery(TDD) have been evaluated by Using ANSYS & computational fluid dynamic (CFD), structural. Micro fluidic analysis has performed to ensure the micro-needles design suitability for Drug delivery. The effect of axial and transverse load on single and micro-needle array has investigated with the mechanical properties of micro-needle. The analysis predicte...

  3. The effect of tube rupture location on the consequences of multiple steam generator tube rupture event

    International Nuclear Information System (INIS)

    Jeong, Ji Hwan; Kweon, Young Chul

    2002-01-01

    A multiple steam generator tube rupture (MSGTR) event has never occurred in the commercial operation of nuclear reactors while single steam generator tube rupture (SGTR) events are reported to occur every 2 years. As there has been no occurrence of a MSGTR event, the understanding of transients and consequences of this event is very limited. In this study, a postulated MSGTR event in an advanced power reactor 1400 (APR 1400) is analyzed using the thermal-hydraulic system code, MARS1.4. The APR 1400 is a two-loop, 3893 MWt, PWR proposed to be built in 2010. The present study aims to understand the effects of rupture location in heat transfer tubes following a MSGTR event. The effects of five tube rupture locations are compared with each other. The comparison shows that the response of APR1400 allows the shortest time for operator action following a tube rupture in the vicinity of the hot-leg side tube sheet and allows the longest time following a tube rupture at the tube top. The MSSV lift time for rupture at the tube-top is evaluated as 24.5% larger than that for rupture at the hot-leg side tube sheet

  4. Development of NDT techniques for the inspection of WSGHWR pressure tubes

    International Nuclear Information System (INIS)

    Gray, B.S.; Highmore, P.J.; Rudlin, J.R.; Cooper, A.G.

    1979-01-01

    The fuel for the Steam Generating Heavy Water Reactor at Winfrith Heath is contained in vertical Zircaloy pressure tubes and is cooled by boiling light water. This paper describes the development of NDT techniques for the inservice examination of the pressure tubes to provide continuing assurance of the absence of axial crack-like defects. The resultant equipment has to operate in water-filled tubes in the presence of the radiation field due to the irradiated fuel elements in adjacent tubes. Also, a layer of surface oxide on the inside of the tubes has been found to significantly affect the behaviour of a prototype inspection device. To provide adequate sensitivity in these conditions, without the occurrence of unnecessary spurious indications, a combination of techniques has been developed. This involves the use of ultrasonics in both pulse-echo and 'pitch and catch' mode together with a single frequency eddy current technique. Laboratory work using artificial defects is described and also how the development programme was modified to accommodate the results of in-reactor tests using a prototype device. Reference is also made to the development of CCTV equipment to provide a supplementary visual examination. (author)

  5. Sealed ion accelerator tubes (survey)

    International Nuclear Information System (INIS)

    Voitsik, L.R.

    1985-01-01

    The first publications on developing commercial models of small-scale sealed accelerator tubes in which neutrons are generated appeared in the foreign press in 1954 to 1957; they were very brief and were advertising-oriented. The tubes were designed for neutron logging of oil wells instead of ampule neutron sources (Po + Be, Ra + Be). Later, instruments of this type began to be called neutron tubes from the resulting neutron radiation that they gave off. In Soviet Union a neutron tube was developed in 1958 in connection with the development of the pulsed neutron-neutron method of studying the geological profile of oil wells. At that time the tube developed was intended, in the view of its inventors, to replace standard isotope sources with constant neutron yield. A fairly detailed survey of neutron tubes was made in the studies. 8 refs., 8 figs

  6. Pitting process visualization

    Directory of Open Access Journals (Sweden)

    Michal Černý

    2010-01-01

    Full Text Available The paper describes time-domain simulation of gear pitting damage using animation program. Key frames have been used to create illusion of motion. The animation uses experimental results of high-cycle fatigue of material. The fatigue damage occurs in the nominal creep area on the side of the gear tooth sample loaded with variable-positioned Hertz pressure. By applying the force, the pressure cumulates between two convex surfaces. This phenomenon results in material damage under of curved surfaces in contact. Moreover, further damage has been registered on the surface. This is due to exceeding the elastic-plastic state limit and development of „tabs“. The tabs serve as origin of surface micro cracks powered by shear stress and enclosed grease pressure as well. This deformation and extreme pressures of Pascal law contribute to elongation and growth of the surface micro crack. Non-homogenous parts of material volume support the initialization/development of the micro cracks as well. Resulting visualization of the tooth-side fatigue damage provides clear and easy-to-understand description of the damage development process right from the micro crack initialization to the final fragmentation due to pitting degradation.

  7. Experimental study of the reflooding of a constricted tube in the REFLEX rig

    International Nuclear Information System (INIS)

    Denham, M.K.; Elliott, D.F.; Britton-Jones, K.A.

    1982-08-01

    The Winfrith experimental programme in support of the PWR is focussed on fuel thermal and hydraulic performance under hypothetical accident conditions, and includes studies of reflooding heat transfer of single tubes and fuel rod clusters under simulated accident conditions, aimed at improving understanding of the processes involved and providing data for code development and validation. The work described is part of a study of the possible effects of clad ballooning on ECCS effectiveness. During a large loss of coolant accident the primary circuit will depressurise and the core will overheat. The Zircaloy fuel cladding may swell, partially blocking the coolant passages by the formation of local ''balloons''. An experiment was carried out in the REFLEX single tube reflooding rig, to study, in a simple geometry, the effect of the partial blockage of the tube on the fluid flow and heat transfer during reflooding. The blockage consisted of a tapering entrance with a flow area 60 percent less than the unconstricted tube, and a tapering exit. The flow could be viewed through windows. 66 refloods were carried out over a pressure range of 1 to 4 bar. Results of these tests are presented. (U.K.)

  8. Numerical and experimental study of a hydrodynamic cavitation tube

    Science.gov (United States)

    Hu, H.; Finch, J. A.; Zhou, Z.; Xu, Z.

    1998-08-01

    A numerical analysis of hydrodynamics in a cavitation tube used for activating fine particle flotation is described. Using numerical procedures developed for solving the turbulent k-ɛ model with boundary fitted coordinates, the stream function, vorticity, velocity, and pressure distributions in a cavitation tube were calculated. The calculated pressure distribution was found to be in excellent agreement with experimental results. The requirement of a pressure drop below approximately 10 m water for cavitation to occur was observed experimentally and confirmed by the model. The use of the numerical procedures for cavitation tube design is discussed briefly.

  9. High-speed infrared thermography for the measurement of microscopic boiling parameters on micro- and nano-structured surfaces

    International Nuclear Information System (INIS)

    Park, Youngjae; Kim, Hyungdae; Kim, Hyungmo; Kim, Joonwon

    2014-01-01

    Micro- and nano-scale structures on boiling surfaces can enhance nucleate boiling heat transfer coefficient (HTC) and critical heat flux (CHF). A few studies were conducted to explain the enhancements of HTC and CHF using the microscopic boiling parameters. Quantitative measurements of microscopic boiling parameters are needed to understand the physical mechanism of the boiling heat transfer augmentation on structured surfaces. However, there is no existing experimental techniques to conveniently measure the boiling parameters on the structured surfaces because of the small (study, we use a high-speed infrared (IR) thermography to visualize liquid-vapor phase distribution during nucleate pool boiling on micro- and nano-structured surfaces. The visualization results are analyzed to obtain the microscopic boiling parameters. Finally, quantitative microscopic boiling parameters are used to interpret the enhancement of HTC and CHF. In this study, liquid-vapor phase distributions of each surface were clearly visualized by IR thermography during the nucleate boiling phenomena. From the visualization results, following microscopic boiling parameters were quantitatively measured by image processing. - Number density of dry patch, NDP IR thermography technique was demonstrated by nucleate pool boiling experiments with M- and N surfaces. The enhancement of HTC and CHF could be explained by microscopic boiling parameters

  10. A novel deep reactive ion etched (DRIE) glass micro-model for two-phase flow experiments.

    Science.gov (United States)

    Karadimitriou, N K; Joekar-Niasar, V; Hassanizadeh, S M; Kleingeld, P J; Pyrak-Nolte, L J

    2012-09-21

    In the last few decades, micro-models have become popular experimental tools for two-phase flow studies. In this work, the design and fabrication of an innovative, elongated, glass-etched micro-model with dimensions of 5 × 35 mm(2) and constant depth of 43 microns is described. This is the first time that a micro-model with such depth and dimensions has been etched in glass by using a dry etching technique. The micro-model was visualized by a novel setup that allowed us to monitor and record the distribution of fluids throughout the length of the micro-model continuously. Quasi-static drainage experiments were conducted in order to obtain equilibrium data points that relate capillary pressure to phase saturation. By measuring the flow rate of water through the flow network for known pressure gradients, the intrinsic permeability of the micro-model's flow network was also calculated. The experimental results were used to calibrate a pore-network model and test its validity. Finally, we show that glass-etched micro-models can be valuable tools in single and/or multi-phase flow studies and their applications.

  11. Novel Design for Centrifugal Countercurrent Chromatography: II. Studies on Novel Geometries of Zigzag Toroidal Tubing

    Science.gov (United States)

    Yang, Yi; Aisa, Haji Akber; Ito, Yoichiro

    2009-01-01

    The toroidal column using a zigzag pattern has been improved in both retention of the stationary phase and peak resolution. To further improve the retention of stationary phase and peak resolution, a series of novel geometric designs of tubing (plain, mid-clamping, flattened and flat-twisted tubing) was evaluated their performance in CCC. The results showed that the tubing which was flattened vertically against centrifugal force (vert-flattened tubing) produced the best peak resolution among them. Using vert-flattened tubing a series of experiments was performed to study the effects of column capacity and sample size. The results indicated that a 0.25 ml capacity column is ideal for analysis of small amount samples. PMID:20454530

  12. In vitro evaluation of the sinus sagittalis superior thrombosis model in the rat using 3D micro- and nanocomputed tomography

    International Nuclear Information System (INIS)

    Langheinrich, Alexander Claus; Ostendorf, Anne; Kampschulte, Marian; Yeniguen, Mesut; Marhoffer, Simone; Nedelmann, Max; Stolz, Erwin; Gerriets, Tibo; Dierkes, Christian; Gerlach, Susanne von; Bachmann, Georg

    2010-01-01

    Thrombosis of the cerebral veins and sinus are common causes of stroke. Animal models help us to understand the underlying pathophysiology of this condition. Therefore, the purpose of our study was to evaluate a well-established model for sinus sagittalis (SSS) thrombosis using micro- and nanocomputed tomography (CT) imaging. SSS thrombosis was performed in four rats. After contrast perfusion, brains were isolated and scanned using micro-CT at (8 μm) 3 voxel size to generate 3D images of the cerebral vasculature. For more detailed information on vascular perfusion territories, nano-CT imaging was performed to investigate the boundary layer of contrast-enhanced vessels and the occluded veins. The venous and arterial vascular volume fraction and gray scale measurements were obtained in the SSS thrombosis group and compared to controls. The significance of differences in vascular volume fraction and gray scale measurements was tested with analysis of variance. Results were complemented with histology. Micro-CT proved to accurately visualize and differentiate vascular occlusion territories performed in the SSS thrombosis model. Moreover, 3D micro-CT provided quantitative information on arterial and venous vascular volume fraction. Micro-CT imaging enables a total 3D visualization of complications (ventricle rupture) in the SSS thrombosis model. We established gray scale measurements by which focal cerebral ischemia could be radiographically categorized (p < 0.001). Using nano-CT, the interface of contrast-perfused and occluded veins can be visualized. Micro-CT is feasible for analysis and differentiation of perfusion territories in an animal model of focal cerebral ischemia. (orig.)

  13. An in vitro comparison of tracheostomy tube cuffs

    Directory of Open Access Journals (Sweden)

    Maguire S

    2015-04-01

    Full Text Available Seamus Maguire,1 Frances Haury,2 Korinne Jew2 1Research and Development, Covidien Respiratory and Monitoring Solutions, Athlone, Ireland; 2Medical Affairs, Covidien Respiratory and Monitoring Solutions, Boulder, CO, USA Introduction: The Shiley™ Flexible adult tracheostomy tube with TaperGuard™ cuff has been designed through its geometry, materials, diameter, and wall thickness to minimize micro-aspiration of fluids past the cuff and to provide an effective air seal in the trachea while also minimizing the risk of excessive contact pressure on the tracheal mucosa. The cuff also has a deflated profile that may allow for easier insertion through the stoma site. This unique design is known as the TaperGuard™ cuff. The purpose of the observational, in vitro study reported here was to compare the TaperGuard™ taper-shaped cuff to a conventional high-volume low-pressure cylindrical-shaped cuff (Shiley™ Disposable Inner Cannula Tracheostomy Tube [DCT] with respect to applied tracheal wall pressure, air and fluid sealing efficacy, and insertion force.Methods: Three sizes of tracheostomy tubes with the two cuff types were placed in appropriately sized tracheal models and lateral wall pressure was measured via pressure-sensing elements on the inner surface. Fluid sealing performance was assessed by inflating the cuffs within the tracheal models (25 cmH2O, instilling water above the cuff, and measuring fluid leakage past the cuff. To measure air leak, tubes were attached to a test lung and ventilator, and leak was calculated by subtracting the average exhaled tidal volume from the average delivered tidal volume. A tensile test machine was used to measure insertion force for each tube with the cuff deflated to simulate clinical insertion through a stoma site.Results: The average pressure exerted on the lateral wall of the model trachea was lower for the taper-shaped cuff than for the cylindrical cuff under all test conditions (P<0.05. The taper

  14. mESAdb: microRNA expression and sequence analysis database.

    Science.gov (United States)

    Kaya, Koray D; Karakülah, Gökhan; Yakicier, Cengiz M; Acar, Aybar C; Konu, Ozlen

    2011-01-01

    microRNA expression and sequence analysis database (http://konulab.fen.bilkent.edu.tr/mirna/) (mESAdb) is a regularly updated database for the multivariate analysis of sequences and expression of microRNAs from multiple taxa. mESAdb is modular and has a user interface implemented in PHP and JavaScript and coupled with statistical analysis and visualization packages written for the R language. The database primarily comprises mature microRNA sequences and their target data, along with selected human, mouse and zebrafish expression data sets. mESAdb analysis modules allow (i) mining of microRNA expression data sets for subsets of microRNAs selected manually or by motif; (ii) pair-wise multivariate analysis of expression data sets within and between taxa; and (iii) association of microRNA subsets with annotation databases, HUGE Navigator, KEGG and GO. The use of existing and customized R packages facilitates future addition of data sets and analysis tools. Furthermore, the ability to upload and analyze user-specified data sets makes mESAdb an interactive and expandable analysis tool for microRNA sequence and expression data.

  15. Microdischarges in DC accelerator tubes

    International Nuclear Information System (INIS)

    Eastham, D.A.; Thorn, R.

    1978-07-01

    Voltage tests on the Daresbury ceramic/titanium accelerator tube have shown that microdischarges play an important role in the conditioning process. It has been found that the voltage onset for microdischarges in a tube is dependent on the surface contamination of the electrodes and the tube geometry (in particular the tube length). This geometrical effect can be related to the trajectories of secondary ions emitted from the electrode surfaces. Sensitive diagnostic techniques have been developed to study the mass and energy distribution of ions emitted along the axis of the tube during these predischarges. The energy distribution of protons (and H - ions) can be related to the origins of the discharges in the tube. Detailed results are presented for a particular tube geometry. (author)

  16. Radiology responsibilities post NPSA guidelines for nasogastric tube insertion: A single centre review

    International Nuclear Information System (INIS)

    Snaith, Beverly; Flintham, Kevin

    2015-01-01

    Background: There are well-recognised complications associated with malposition of nasogastric (NG) tubes. In 2011 the UK National Patient Safety Agency (NPSA) published an alert regarding their insertion and position confirmation. This alert also identified the expected radiology standards for both image acquisition and reporting. Method: This was a retrospective review of referrals over a six-month period within a multi-site NHS Trust. A consecutive sampling approach was used and radiology reports where the text included the terms “NG tube”, “nasogastric” or “feeding” were included. Data were collected from the radiology information system and NG tube visibility and image quality were confirmed by two independent reviewers. Results: 1137 examinations demonstrated an NG tube, of which 68.3% were performed to check tube position. There was statistically significant correlation between lower radiation exposure and non-visualisation (Fishers exact test, p < 0.001). The number of examinations with higher exposure index (EI) in the NG check cohort suggests that the radiographer increased the exposure to improve visualization (x 2  = 2.846; 95% CI; p = 0.046), although the utility of this is unproven. Malplaced tubes were demonstrated either in the respiratory tract (1.8%) or proximal gastrointestinal tract (8.6%) as a result of insufficient length introduced. Conclusion: The prompt acquisition and reporting of radiographs is essential to reduce the risk of NG tube complications. Respiratory tract misplacement rates were in line with the published literature, but this study does raise concern regarding the number of tubes located in the proximal GI tract. Radiology's responsibility in accurate and effective reporting of medical interventions is significant

  17. Lyme Disease and YouTube TM: A Cross-Sectional Study of Video Contents.

    Science.gov (United States)

    Basch, Corey H; Mullican, Lindsay A; Boone, Kwanza D; Yin, Jingjing; Berdnik, Alyssa; Eremeeva, Marina E; Fung, Isaac Chun-Hai

    2017-08-01

    Lyme disease is the most common tick-borne disease. People seek health information on Lyme disease from YouTube TM videos. In this study, we investigated if the contents of Lyme disease-related YouTube TM videos varied by their sources. Most viewed English YouTube TM videos (n = 100) were identified and manually coded for contents and sources. Within the sample, 40 videos were consumer-generated, 31 were internet-based news, 16 were professional, and 13 were TV news. Compared with consumer-generated videos, TV news videos were more likely to mention celebrities (odds ratio [OR], 10.57; 95% confidence interval [CI], 2.13-52.58), prevention of Lyme disease through wearing protective clothing (OR, 5.63; 95% CI, 1.23-25.76), and spraying insecticides (OR, 7.71; 95% CI, 1.52-39.05). A majority of the most popular Lyme disease-related YouTube TM videos were not created by public health professionals. Responsible reporting and creative video-making facilitate Lyme disease education. Partnership with YouTube TM celebrities to co-develop educational videos may be a future direction.

  18. Spatial distribution of enzyme driven reactions at micro-scales

    Science.gov (United States)

    Kandeler, Ellen; Boeddinghaus, Runa; Nassal, Dinah; Preusser, Sebastian; Marhan, Sven; Poll, Christian

    2017-04-01

    Studies of microbial biogeography can often provide key insights into the physiologies, environmental tolerances, and ecological strategies of soil microorganisms that dominate in natural environments. In comparison with aquatic systems, soils are particularly heterogeneous. Soil heterogeneity results from the interaction of a hierarchical series of interrelated variables that fluctuate at many different spatial and temporal scales. Whereas spatial dependence of chemical and physical soil properties is well known at scales ranging from decimetres to several hundred metres, the spatial structure of soil enzymes is less clear. Previous work has primarily focused on spatial heterogeneity at a single analytical scale using the distribution of individual cells, specific types of organisms or collective parameters such as bacterial abundance or total microbial biomass. There are fewer studies that have considered variations in community function and soil enzyme activities. This presentation will give an overview about recent studies focusing on spatial pattern of different soil enzymes in the terrestrial environment. Whereas zymography allows the visualization of enzyme pattern in the close vicinity of roots, micro-sampling strategies followed by MUF analyses clarify micro-scale pattern of enzymes associated to specific microhabitats (micro-aggregates, organo-mineral complexes, subsoil compartments).

  19. Can balneotherapy modify microRNA expression levels in osteoarthritis? A comparative study in patients with knee osteoarthritis

    Science.gov (United States)

    Giannitti, C.; De Palma, A.; Pascarelli, N. A.; Cheleschi, S.; Giordano, N.; Galeazzi, M.; Fioravanti, Antonella

    2017-12-01

    The aim of this study was to evaluate the whole-blood levels of miR-155, miR-223, miR-181a, miR-146a, and miR-let-7e in patients with bilateral knee osteoarthritis (OA) after a cycle of mud-bath therapy (MBT). Thirty-two patients with knee OA defined by the ACR criteria were included. Twenty-one patients (MBT group) were daily treated with a combination of local mud-packs at 42 °C and baths in mineral water, at 37 °C for 15 min, for 12 applications over a period of 2 weeks, in addition to standard therapy; 11 patients (control group) continued their conventional treatment alone. Global pain score evaluated by visual analog scale (VAS), WOMAC subscores, and microRNA expression were evaluated at baseline and after 2 weeks. Peripheral whole blood was collected into PAXgene™ Blood RNA tubes, stored at - 80 °C, and total RNA was extracted. The expression of miR-155, miR-223, miR-181a, miR-146a, and miR-let-7e was determined by qRT-PCR. After MBT, we observed a statistically significant improvement of clinical parameters and a significant decrease of miR-155, miR-181a, miR-146a ( p < 0.001), and miR-223 ( p < 0.01) expression levels. No clinical and biochemical modifications were detected in the control group. No significant variations of miR-let-7e were shown in both groups after 2 weeks. In conclusion, MBT can modify the expression of miR-155, miR-181a, miR-146a, and miR-223, which are upregulated in OA. It could be due to the heat stress and the hydrostatic pressure, since some miRNAs were found to be temperature- and mechano-responsive. Further studies are needed to better explain the mechanism of action of MBT and the role of miRNAs in OA.

  20. A micro-coupling for micro mechanical systems

    Science.gov (United States)

    Li, Wei; Zhou, Zhixiong; Zhang, Bi; Xiao, Yunya

    2016-05-01

    The error motions of micro mechanical systems, such as micro-spindles, increase with the increasing of the rotational speed, which not only decreases the rotational accuracy, but also promotes instability and limits the maximum operational speed. One effective way to deal with it is to use micro-flexible couplings between the drive and driven shafts so as to reduce error motions of the driven shaft. But the conventional couplings, such as diaphragm couplings, elastomeric couplings, bellows couplings, and grooved couplings, etc, cannot be directly used because of their large and complicated structures. This study presents a novel micro-coupling that consists of a flexible coupling and a shape memory alloy (SMA)-based clamp for micro mechanical systems. It is monolithic and can be directly machined from a shaft. The study performs design optimization and provides manufacturing considerations, including thermo-mechanical training of the SMA ring for the desired Two-Way-Shape-Memory effect (TWSMe). A prototype micro-coupling and a prototype micro-spindle using the proposed coupling are fabricated and tested. The testing results show that the prototype micro-coupling can bear a torque of above 5 N • mm and an axial force of 8.5 N and be fitted with an SMA ring for clamping action at room temperature (15 °C) and unclamping action below-5 °C. At the same time, the prototype micro-coupling can work at a rotational speed of above 200 kr/min with the application to a high-speed precision micro-spindle. Moreover, the radial runout error of the artifact, as a substitute for the micro-tool, is less than 3 μm while that of turbine shaft is above 7 μm. It can be concluded that the micro-coupling successfully accommodates misalignment errors of the prototype micro-spindle. This research proposes a micro-coupling which is featured with an SMA ring, and it is designed to clamp two shafts, and has smooth transmission, simple assembly, compact structure, zero-maintenance and

  1. Application of blue-green and ultraviolet micro-LEDs to biological imaging and detection

    International Nuclear Information System (INIS)

    Xu, H; Zhang, J; Nurmikko, A V; Davitt, K M; Song, Y-K

    2008-01-01

    This paper reviews authors' laboratory's work on the development of nitride-based blue-green and ultraviolet microscale LED devices with particular classes of imaging and spectroscopic applications in cellular level biology. Starting from neuroscience, we illustrate the utility of blue-green micro-LEDs for voltage-sensitive dye imaging of individual neural cells, as well as their ultraviolet counterparts for photostimulation of neurons. Arrays of micro-LEDs are also shown to be useful in projecting spatiotemporal patterns of photoexcitation to study the visual system development in living animals. As another illustration of the utility of the emerging nitride microdevice technology, we demonstrate the application of UV micro-LED arrays in bio-sensing technology as the core of a real-time fluorescence spectroscopy biowarning system. (invited paper)

  2. Nondestructive Analysis of Astromaterials by Micro-CT and Micro-XRF Analysis for PET Examination

    Science.gov (United States)

    Zeigler, R. A.; Righter, K.; Allen, C. C.

    2013-01-01

    An integral part of any sample return mission is the initial description and classification of returned samples by the preliminary examination team (PET). The goal of the PET is to characterize and classify returned samples and make this information available to the larger research community who then conduct more in-depth studies on the samples. The PET tries to minimize the impact their work has on the sample suite, which has in the past limited the PET work to largely visual, nonquantitative measurements (e.g., optical microscopy). More modern techniques can also be utilized by a PET to nondestructively characterize astromaterials in much more rigorous way. Here we discuss our recent investigations into the applications of micro-CT and micro-XRF analyses with Apollo samples and ANSMET meteorites and assess the usefulness of these techniques in future PET. Results: The application of micro computerized tomography (micro-CT) to astromaterials is not a new concept. The technique involves scanning samples with high-energy x-rays and constructing 3-dimensional images of the density of materials within the sample. The technique can routinely measure large samples (up to approx. 2700 cu cm) with a small individual voxel size (approx. 30 cu m), and has the sensitivity to distinguish the major rock forming minerals and identify clast populations within brecciated samples. We have recently run a test sample of a terrestrial breccia with a carbonate matrix and multiple igneous clast lithologies. The test results are promising and we will soon analyze a approx. 600 g piece of Apollo sample 14321 to map out the clast population within the sample. Benchtop micro x-ray fluorescence (micro-XRF) instruments can rapidly scan large areas (approx. 100 sq cm) with a small pixel size (approx. 25 microns) and measure the (semi) quantitative composition of largely unprepared surfaces for all elements between Be and U, often with sensitivity on the order of a approx. 100 ppm. Our recent

  3. Comparative analysis of intraoral radiographs with variation of tube angulation to detect insufficient crown margins.

    Science.gov (United States)

    Sailer, Benjamin F; Geibel, Margrit-Ann

    2013-01-01

    Variations in angulation of the x-ray tube affect the appearance of insufficient approximal crown margins on intraoral radiographs. This study examines the impact of such angular variation on the assessment of digital radiographs using three different X-ray tubes--Heliodent DS (Sirona), Gendex Expert DC (KaVo Dental) and Focus (KaVo Dental)--as well as the Gendex Visualix eHD CCD sensor (KaVo Dental). The test specimens, crowned teeth 46 from two mandibles provided by the Institute of Anatomy and Cell Biology, were examined with each tube. The results indicate great differences in the angles indicative of insufficient crown margins on X-ray images. Because of beam divergence and the crown marginal gap, the length and width of which frequently varies, it is difficult to infer any optimum angle from the data. This leads to the conclusion that at present, it is not possible to establish ideal angles for visualization of insufficient approximal crown margins.

  4. Experimental and numerical study of micro deep drawing

    Directory of Open Access Journals (Sweden)

    Luo Liang

    2015-01-01

    Full Text Available Micro forming is a key technology for an industrial miniaturisation trend, and micro deep drawing (MDD is a typical micro forming method. It has great advantages comparing to other micro manufacturing methods, such as net forming ability, mass production potential, high product quality and complex 3D metal products fabrication capacity. Meanwhile, it is facing difficulties, for example the so-called size effects, once scaled down to micro scale. To investigate and to solve the problems in MDD, a combined micro blanking-drawing machine is employed and an explicit-implicit micro deep drawing model with a voronoi blank model is developed. Through heat treatment different grain sizes can be obtained, which affect material's properties and, consequently, the drawing process parameters, as well as produced cups' quality. Further, a voronoi model can provide detailed material information in simulation, and numerical simulation results are in accordance with experimental results.

  5. Flaming on YouTube

    NARCIS (Netherlands)

    Moor, Peter J.; Heuvelman, A.; Verleur, R.

    2010-01-01

    In this explorative study, flaming on YouTube was studied using surveys of YouTube users. Flaming is defined as displaying hostility by insulting, swearing or using otherwise offensive language. Three general conclusions were drawn. First, although many users said that they themselves do not flame,

  6. A novel method for passing cerebrospinal fluid shunt tubing: a proof of principle study.

    Science.gov (United States)

    Tubbs, R Shane; Goodrich, Dylan; Tubbs, Isaiah; Loukas, Marios; Cohen-Gadol, Aaron A

    2014-12-01

    Few innovations in the method of tunneling shunt tubing for cerebrospinal fluid (CSF) shunt diversion have been made since this treatment of hydrocephalus was first developed. Therefore, this feasibility study was performed with the hope of identifying an improved technique that could potentially carry fewer complications. On 10 cadaver sides and when placed in the supine position, small skin incisions were made at the clavicle and ipsilateral subcostal region, and magnets were used to pass standard shunt tubing between the two incisions. Nickel-plated magnets were less effective in pulling the shunt tubing below the skin compared with ceramic magnets. Of these, magnets with pull strengths of 150-200 lbs were the most effective in dragging the subcutaneous tubing between the two incisions. No obvious damage to the skin from the overlying magnet was seen in any specimen. Few options exist for tunneling distal shunt tubing for CSF shunt procedures. Future patient studies are needed to determine if the technique described herein is superior to current methods, particularly when examining patient groups that are at a greater risk for injury during tunneling shunt catheters.

  7. In Vitro Evaluation of Linezolid and Meropenem Against Clinical Isolates of Multi Drug Resistant Tuberculosis By Mycobacterial Growth Indicator Tube (MGIT) 960

    International Nuclear Information System (INIS)

    Mirza, I. A.; Satti, L.; Khan, F. A.; Khan, K. A.

    2015-01-01

    Objective: To evaluate the in vitro effectiveness of multiple breakpoint concentrations of newer antituberculosis agents (Linezolid and Meropenem) against Multi Drug-Resistant Tuberculosis (MDR-TB) isolates. Study Design: Adescriptive cross-sectional study. Place and Duration of Study: Microbiology Department, Armed Forces Institute of Pathology (AFIP), Rawalpindi, from September 2011 to August 2013. Methodology: Atotal of 100 MDR-TB isolates recovered during the study period were subjected to susceptibility testing against multiple breakpoint concentrations of Linezolid (LZD) and Meropenem (MER). The breakpoint concentration used for LZD were 0.5, 1.0 and 2.0 micro g/ml, while for MER were 4.0, 8.0 and 16 micro g/ml. Mycobacterial Growth Indicator Tube (MGIT) 960 system was used to carry out drug susceptibility testing as per recommended protocol. Results: At break point concentration of 0.5 micro g/ml, 80 out of 100 (80%) MDR-TB isolates were susceptible to LZD while at breakpoint concentration of 1.0 micro g/ml and 2.0 micro g/ml, 96/100, (96%) of MDR-TB isolates were susceptible. For MER, at breakpoint concentrations of 4.0 micro g/ml no MDR-TB isolate was susceptible, while at 8.0 micro g/ml 3/100, (3%) and at 16.0 micro g/ml 11/100, (11%) of MDR-TB isolates were susceptible. Conclusion: LZD was found to have excellent in vitroefficacy as 96% of MDR-TB isolates were susceptible at breakpoint concentration of 1.0 micro g/ml or more. In case of MER it was found that in vitrosusceptibility improved as the break point concentrations were increased. (author)

  8. Tube failures due to cooling process problem and foreign materials in power plants

    Energy Technology Data Exchange (ETDEWEB)

    Ahmad, J. [Kapar Energy Ventures Sdn Bhd, Jalan Tok Muda, Kapar 42200 (Malaysia); Purbolaksono, J., E-mail: judha@uniten.edu.m [Department of Mechanical Engineering, Universiti Tenaga Nasional, Km 7 Jalan Kajang-Puchong, Kajang 43009, Selangor (Malaysia); Beng, L.C. [Kapar Energy Ventures Sdn Bhd, Jalan Tok Muda, Kapar 42200 (Malaysia)

    2010-07-15

    Cooling process which uses water for heat transfer is an essential factor in coal-fired and nuclear plants. Loss of cooling upset can force the plants to shut down. In particular, this paper reports visual inspections and metallurgical examinations on the failed SA210-A1 right-hand side (RHS) water wall tube of a coal-fired plant. The water wall tube showed the abnormal outer surface colour and has failed with wide-open ductile rupture and thin edges indicating typical signs of short-term overheating. Metallurgical examinations confirmed the failed tube experiencing higher temperature operation. Water flow starvation due to restriction inside the upstream tube is identified as the main root cause of failure. The findings are important to take failure mitigation actions in the future operation. Discussion on the typical problems related to the cooling process in nuclear power plants is also presented.

  9. Tube failures due to cooling process problem and foreign materials in power plants

    International Nuclear Information System (INIS)

    Ahmad, J.; Purbolaksono, J.; Beng, L.C.

    2010-01-01

    Cooling process which uses water for heat transfer is an essential factor in coal-fired and nuclear plants. Loss of cooling upset can force the plants to shut down. In particular, this paper reports visual inspections and metallurgical examinations on the failed SA210-A1 right-hand side (RHS) water wall tube of a coal-fired plant. The water wall tube showed the abnormal outer surface colour and has failed with wide-open ductile rupture and thin edges indicating typical signs of short-term overheating. Metallurgical examinations confirmed the failed tube experiencing higher temperature operation. Water flow starvation due to restriction inside the upstream tube is identified as the main root cause of failure. The findings are important to take failure mitigation actions in the future operation. Discussion on the typical problems related to the cooling process in nuclear power plants is also presented.

  10. Leakage Characteristics of Dual-Cannula Fenestrated Tracheostomy Tubes during Positive Pressure Ventilation: A Bench Study

    Directory of Open Access Journals (Sweden)

    Thomas Berlet

    2016-01-01

    Full Text Available This study compared the leakage characteristics of different types of dual-cannula fenestrated tracheostomy tubes during positive pressure ventilation. Fenestrated Portex® Blue Line Ultra®, TRACOE® twist, or Rüsch® Traceofix® tracheostomy tubes equipped with nonfenestrated inner cannulas were tested in a tracheostomy-lung simulator. Transfenestration pressures and transfenestration leakage rates were measured during positive pressure ventilation. The impact of different ventilation modes, airway pressures, temperatures, and simulated static lung compliance settings on leakage characteristics was assessed. We observed substantial differences in transfenestration pressures and transfenestration leakage rates. The leakage rates of the best performing tubes were <3.5% of the delivered minute volume. At body temperature, the leakage rates of these tracheostomy tubes were <1%. The tracheal tube design was the main factor that determined the leakage characteristics. Careful tracheostomy tube selection permits the use of fenestrated tracheostomy tubes in patients receiving positive pressure ventilation immediately after stoma formation and minimises the risk of complications caused by transfenestration gas leakage, for example, subcutaneous emphysema.

  11. Steam generator tubes rupture probability estimation - study of the axially cracked tube case

    International Nuclear Information System (INIS)

    Mavko, B.; Cizelj, L.; Roussel, G.

    1992-01-01

    The objective of the present study is to estimate the probability of a steam generator tube rupture due to the unstable propagation of axial through-wall cracks during a hypothetical accident. For this purpose the probabilistic fracture mechanics model was developed taking into account statistical distributions of influencing parameters. A numerical example considering a typical steam generator seriously affected by axial stress corrosion cracking in the roll transition area, is presented; it indicates the change of rupture probability with different assumptions focusing mostly on tubesheet reinforcing factor, crack propagation rate and crack detection probability. 8 refs., 4 figs., 4 tabs

  12. Erbium-Based Perfusion Contrast Agent for Small-Animal Microvessel Imaging

    Directory of Open Access Journals (Sweden)

    Justin J. Tse

    2017-01-01

    Full Text Available Micro-computed tomography (micro-CT facilitates the visualization and quantification of contrast-enhanced microvessels within intact tissue specimens, but conventional preclinical vascular contrast agents may be inadequate near dense tissue (such as bone. Typical lead-based contrast agents do not exhibit optimal X-ray absorption properties when used with X-ray tube potentials below 90 kilo-electron volts (keV. We have developed a high-atomic number lanthanide (erbium contrast agent, with a K-edge at 57.5 keV. This approach optimizes X-ray absorption in the output spectral band of conventional microfocal spot X-ray tubes. Erbium oxide nanoparticles (nominal diameter 4000 Hounsfield units, and perfusion of vessels < 10 μm in diameter was demonstrated in kidney glomeruli. The described new contrast agent facilitated the visualization and quantification of vessel density and microarchitecture, even adjacent to dense bone. Erbium’s K-edge makes this contrast agent ideally suited for both single- and dual-energy micro-CT, expanding potential preclinical research applications in models of musculoskeletal, oncological, cardiovascular, and neurovascular diseases.

  13. Synchrotron X-ray PIV Technique for Measurement of Blood Flow Velocity

    International Nuclear Information System (INIS)

    Kim, Guk Bae; Lee, Sang Joon; Je, Jung Ho

    2007-01-01

    Synchrotron X-ray micro-imaging method has been used to observe internal structures of various organisms, industrial devices, and so on. However, it is not suitable to see internal flows inside a structure because tracers typically employed in conventional optical flow visualization methods cannot be detectable with the X-ray micro-imaging method. On the other hand, a PIV (particle image velocimetry) method which has recently been accepted as a reliable quantitative flow visualization technique can extract lots of flow information by applying digital image processing techniques However, it is not applicable to opaque fluids such as blood. In this study, we combined the PIV method and the synchrotron X-ray micro-imaging technique to compose a new X-ray PIV technique. Using the X-ray PIV technique, we investigated the optical characteristics of blood for a coherent synchrotron X-ray beam and quantitatively visualized real blood flows inside an opaque tube without any contrast media. The velocity field information acquired would be helpful for investigating hemorheologic characteristics of the blood flow

  14. Experimental and numerical studies of micro PEM fuel cell

    Science.gov (United States)

    Peng, Rong-Gui; Chung, Chen-Chung; Chen, Chiun-Hsun

    2011-10-01

    A single micro proton exchange membrane fuel cell (PEMFC) has been produced using Micro-electromechanical systems (MEMS) technology with the active area of 2.5 cm2 and channel depth of about 500 µm. A theoretical analysis is performed in this study for a novel MEMS-based design of amicro PEMFC. Themodel consists of the conservation equations of mass, momentum, species and electric current in a fully integrated finite-volume solver using the CFD-ACE+ commercial code. The polarization curves of simulation are well correlated with experimental data. Three-dimensional simulations are carried out to treat prediction and analysis of micro PEMFC temperature, current density and water distributions in two different fuel flow rates (15 cm3/min and 40 cm3/min). Simulation results show that temperature distribution within the micro PEMFC is affected by water distribution in the membrane and indicate that low and uniform temperature distribution in the membrane at low fuel flow rates leads to increased membrane water distribution and obtains superior micro PEMFC current density distribution under 0.4V operating voltage. Model predictions are well within those known for experimental mechanism phenomena.

  15. P3-7: On Prototyping a Visual Prosthesis System with Artificial Retina and Optic Nerve Based on Arrayed Microfibers

    Directory of Open Access Journals (Sweden)

    Jian Hong Chen

    2012-10-01

    Full Text Available The traditional visual prosthesis system combines both a camera and a microelectrode array implanted on the visual neural network including retina, optic nerve, and visual cortex. Here, we introduce a new visual prosthesis system in which an artificial retina and optic nerve are demonstrated. The prototype of optic nerve for image transmission is comprised of arrayed PMMA microfibers with both ends connected with two planes, one functioned as retina for light reception and another attached to visual cortex. The microfibers are drawn from the thin film prepared by PMMA/chlorobenzene solution. Each micro fiber serves as an optical waveguide for the delivery of a single image pixel. It is demonstrated that with proper imaging optics, arrayed micro fibers could be lit as discrete light spots in accordance with the input image. Each micro fiber is expected to function as a stimulation unit for optical neural modulation in a visual prosthesis system.

  16. YouTube and 'psychiatry'.

    Science.gov (United States)

    Gordon, Robert; Miller, John; Collins, Noel

    2015-12-01

    YouTube is a video-sharing website that is increasingly used to share and disseminate health-related information, particularly among younger people. There are reports that social media sites, such as YouTube, are being used to communicate an anti-psychiatry message but this has never been confirmed in any published analysis of YouTube clip content. This descriptive study revealed that the representation of 'psychiatry' during summer 2012 was predominantly negative. A subsequent smaller re-analysis suggests that the negative portrayal of 'psychiatry' on YouTube is a stable phenomenon. The significance of this and how it could be addressed are discussed.

  17. Micro tomography prototype by positron emission. Spatial resolution and metabolic studies;Prototipo de microtomografo por emision de positrones. Resolucion espacial y estudios metabolicos

    Energy Technology Data Exchange (ETDEWEB)

    Alva S, H.; Murrieta, T.; Ruiz T, C.; Brandan, M. E.; Martinez D, A.; Rodriguez V, M., E-mail: halva@fisica.unam.m [UNAM, Instituto de Fisica, Circuito de la Investigacion Cientifica s/n, Ciudad Universitaria, 04510 Mexico D. F. (Mexico)

    2010-07-01

    During the past 4 years, the Medical Physics and Dosimetry Group at the Physics Institute, UNAM, has developed a positron emission tomography prototype for small-animal imaging (micro PET). The system is composed of pix elated, cerium-doped lutetium yttrium oxy orthosilicate scintillation crystal arrays coupled to position-sensitive photomultiplier tubes. Detector electronic signals are processed by nuclear instrumentation modules and are digitized by a multichannel data acquisition board. The tomographic reconstruction is performed by filtered backprojection from a set of distortion- and nonuniformity- corrected projections taken at different angles. In this work, the reconstructed spatial resolution was evaluated from the line spread function with a mean value of 2.36 +- 0.44 mm. In addition, the first metabolic studies of 30 g, healthy mice, injected with {sup 1}8{sup F} labeled fluorodeoxyglucose and sodium fluoride are reported. They display normal glucose uptake and skeletal structure, respectively. The micro PET can be a useful tool for radiation detector physics research and its applications in nuclear medicine. (Author)

  18. The use of laser-induced plasma spectroscopy technique for the characterization of boiler tubes

    International Nuclear Information System (INIS)

    Nicolas, G.; Mateo, M.P.; Yanez, A.

    2007-01-01

    The present work focuses on the characterization of boiler tube walls using laser-induced plasma spectroscopy technique with visual inspection by optical and scanning electron microscopy of the cross-sections of these tubes. In a watertube boiler, water runs through tubes that are surrounded by a heating source. As a result, the water is heated to very high temperatures, causing accumulation of deposits on the inside surfaces of the tubes. These deposits play an important role in the efficiency of the boiler tube because they produce a reduction of the boiler heat rate and an increase in the number of tube failures. The objectives are to determine the thickness and arrangement of deposits located on the highest heat area of the boiler and compare them with tube parts where the heat flux is lower. The major deposits found were copper and magnetite. These deposits come mainly from the boiler feedwater and from the reaction between iron and water, and they do not form on the tube walls at a uniform rate over time. Their amount depends on the areas where they are collected. A Nd:YAG laser operating at 355 nm has been used to perform laser-induced plasma spectra and depth profiles of the deposits

  19. The use of laser-induced plasma spectroscopy technique for the characterization of boiler tubes

    Science.gov (United States)

    Nicolas, G.; Mateo, M. P.; Yañez, A.

    2007-12-01

    The present work focuses on the characterization of boiler tube walls using laser-induced plasma spectroscopy technique with visual inspection by optical and scanning electron microscopy of the cross-sections of these tubes. In a watertube boiler, water runs through tubes that are surrounded by a heating source. As a result, the water is heated to very high temperatures, causing accumulation of deposits on the inside surfaces of the tubes. These deposits play an important role in the efficiency of the boiler tube because they produce a reduction of the boiler heat rate and an increase in the number of tube failures. The objectives are to determine the thickness and arrangement of deposits located on the highest heat area of the boiler and compare them with tube parts where the heat flux is lower. The major deposits found were copper and magnetite. These deposits come mainly from the boiler feedwater and from the reaction between iron and water, and they do not form on the tube walls at a uniform rate over time. Their amount depends on the areas where they are collected. A Nd:YAG laser operating at 355 nm has been used to perform laser-induced plasma spectra and depth profiles of the deposits.

  20. Tube holding system

    International Nuclear Information System (INIS)

    Cunningham, R.C.

    1978-01-01

    A tube holding rig is described for the lateral support of tubes arranged in tight parcels in a heat exchanger. This tube holding rig includes not less than two tube supporting assemblies, with a space between them, located crosswise with respect to the tubes, each supporting assembly comprising a first set of parallel components in contact with the tubes, whilst a second set of components is also in contact with the tubes. These two sets of parts together define apertures through which the tubes pass [fr

  1. Study of the three-step photoionization of uranium using a hollow cathode discharge tube

    International Nuclear Information System (INIS)

    Hu, Q.; Yin, L.; Zhang, Y.; Jin, C.; Cui, J.; Su, H.; Lin, F.

    1986-01-01

    The hollow cathode discharge (HCD) tube as a spectral light source has been developed. Because any element including refractory metals can be atomized by the cathode sputtering effect in HCD, a simple and reliable atomic vapor source produced by HCD has been widely used in laser spectroscopy. To the authors' knowledge, there is no previous work on the photoionization processes of metal atoms using an HCD tube. Here the authors report their study of the resonant three-step ionization of U in a homemade HCD tube

  2. Tensile strength of Zr-2.5 Nb pressure tubes: A statistical study

    Energy Technology Data Exchange (ETDEWEB)

    Shah, Priti Kotak, E-mail: pritik@barc.gov.in [Senior Scientist, Bhabha Atomic Research Centre, Mumbai, 400 085 (India); Dubey, J.S.; Datta, D.; Shriwastaw, R.S.; Rath, B.N.; Singh, R.N. [Senior Scientist, Bhabha Atomic Research Centre, Mumbai, 400 085 (India); Anantharaman, S. [Head, Post Irradiation Examination Division, Bhabha Atomic Research Centre, Mumbai (India); Chakravartty, J.K. [Director, Materials Group, Bhabha Atomic Research Centre, Mumbai (India)

    2015-12-15

    Highlights: • Tensile properties in axial and transverse direction for a number of Indian Zr-2.5 Nb PHWR pressure tubes. • Distribution of tensile properties of double-melted and quadruple-melted pressure tubes. • Tensile properties at front-end and back-end of the quadruple melted pressure tubes at room temperature and at 300 °C. - Abstract: In order to get an idea of the statistical variation in the tensile properties of the double-melted as well as quadruple melted Zr-2.5 Nb pressure tubes (PTs) and also the variation in tensile properties between the two ends of the pressure tubes, tension tests were carried out on around 50 pressure tube off-cuts. Longitudinal and transverse tensile specimens were prepared from these off-cuts of pressure tubes of double-melted and quadruple melted types. For quadruple melted pressure tubes the specimens were tested from both front-end and back-end off-cuts. Miniature flat tensile specimens having 1.8 mm width and 1.5 mm thickness and 7.6 mm gauge length were prepared from the pressure tube off-cuts without any flattening treatment. Tension tests were carried out in a screw-driven machine at room temperature and 300 °C for both front-end and back-end off-cuts of each of 16 pressure tubes. In general the transverse specimens showed higher yield strength (YS) and ultimate tensile strength (UTS) compared to the longitudinal specimens. Transverse specimens showed less strain hardening compared to the longitudinal specimens. The axial specimens showed higher uniform (UE) and total elongation (TE) compared to the transverse specimens. Double-melted pressure tubes showed relatively higher strength and lower elongation and larger standard deviation compared to the quadruple melted pressure tubes. Mean values of tensile properties showed that back-end off-cuts were relatively stronger and less ductile compared to the front-end off-cuts.

  3. Visual test of subparts per billion-level mercuric ion with a gold nanoparticle probe after preconcentration by hollow fiber supported liquid membrane.

    Science.gov (United States)

    Tan, Zhi-qiang; Liu, Jing-fu

    2010-05-15

    With the combination of the gold nanoparticle (AuNP)-based visual test with hollow fiber supported liquid membrane (HFSLM) extraction, a highly sensitive and selective method was developed for field detection of mercuric ion (Hg(2+)) in environmental waters. Hg(2+) in water samples was extracted through HFSLM and trapped in the aqueous acceptor and then visually detected based on the red-to-blue color change of 3-mercaptopropionic acid-functionalized AuNP (MPA-AuNP) probe. The highest extraction efficiency of Hg(2+) was obtained by using a 600 mL sample (pH 8.0, 2.0% (w/v) NaCl), approximately 35 microL of acceptor (10 mM of 2,6-pyridinedicarboxylic acid, pH 4.0) filled in the lumen of a polypropylene hollow fiber tubing (55 cm in length, 50 microm wall thickness, 280 microm inner diameter), a liquid membrane of 2.0% (w/v) trioctycphosphine oxide in undecane, and a shaking rate of 250 rpm. The chromegenic reaction was conducted by incubating the mixture of MPA-AuNP stock solution (12 microL, 15 nM), Tris-borate buffer solution (18 microL, 0.2 M, pH 9.5), and acceptor (30 microL) at 30 degrees C for 1 h. The detection limit can be adjusted to 0.8 microg/L Hg(2+) (corresponding to an enrichment factor of approximately 1000 in the HFSLM) and 2.0 microg/L Hg(2+) (the U.S. Environmental Protection Agency limit of [Hg(2+)] for drinkable water) by using extraction times of 3 and 1 h, respectively. The proposed method is extremely specific for Hg(2+) with tolerance to at least 1000-fold of other environmentally relevant heavy and transition metal ions and was successfully applied to detect Hg(2+) in a certified reference water sample, as well as real river, lake, and tap water samples.

  4. HF electronic tubes. Technologies, grid tubes and klystrons

    International Nuclear Information System (INIS)

    Lemoine, Th.

    2009-01-01

    This article gives an overview of the basic technologies of electronic tubes: cathodes, electronic optics, vacuum and high voltage. Then the grid tubes, klystrons and inductive output tubes (IOT) are introduced. Content: 1 - context and classification; 2 - electronic tube technologies: cathodes, electronic optics, magnetic confinement (linear tubes), periodic permanent magnet (PPM) focussing, collectors, depressed collectors; 3 - vacuum technologies: vacuum quality, surface effects and interaction with electrostatic and RF fields, secondary emission, multipactor effect, thermo-electronic emission; 4 - grid tubes: operation of a triode, tetrodes, dynamic operation and classes of use, 'common grid' and 'common cathode' operation, ranges of utilisation and limitations, operation of a tetrode on unadjusted load, lifetime of a tetrode, uses of grid tubes; 5 - klystrons: operation, impact of space charge, multi-cavity klystrons, interaction efficiency, extended interaction klystrons, relation between interaction efficiency, perveance and efficiency, ranges of utilization and power limitations, multi-beam klystrons and sheet beam klystrons, operation on unadjusted load, klystron band pass and lifetime, uses; 6 - IOT: principle of operation, ranges of utilisation and limitations, interaction efficiency and depressed collector IOT, IOT lifetime and uses. (J.S.)

  5. A feast of visualization

    Science.gov (United States)

    2008-12-01

    Strength through structure The visualization and assessment of inner human bone structures can provide better predictions of fracture risk due to osteoporosis. Using micro-computed tomography (µCT), Christoph Räth from the Max Planck Institute for Extraterrestrial Physics and colleagues based in Munich, Vienna and Salzburg have shown how complex lattice-shaped bone structures can be visualized. The structures were quantified by calculating certain "texture measures" that yield new information about the stability of the bone. A 3D visualization showing the variation with orientation of one of the texture measures for four different bone specimens (from left to right) is shown above. Such analyses may help us to improve our understanding of disease and drug-induced changes in bone structure (C Räth et al. 2008 New J. Phys. 10 125010).

  6. Recent micro-CT scanner developments at UGCT

    Energy Technology Data Exchange (ETDEWEB)

    Dierick, Manuel, E-mail: Manuel.Dierick@UGent.be [UGCT-Department of Physics and Astronomy, Faculty of Sciences, Ghent University, Proeftuinstraat 86, 9000 Ghent (Belgium); XRE, X-Ray Engineering bvba, De Pintelaan 111, 9000 Ghent (Belgium); Van Loo, Denis, E-mail: info@XRE.be [XRE, X-Ray Engineering bvba, De Pintelaan 111, 9000 Ghent (Belgium); Masschaele, Bert [UGCT-Department of Physics and Astronomy, Faculty of Sciences, Ghent University, Proeftuinstraat 86, 9000 Ghent (Belgium); XRE, X-Ray Engineering bvba, De Pintelaan 111, 9000 Ghent (Belgium); Van den Bulcke, Jan [UGCT-Woodlab-UGent, Department of Forest and Water Management, Faculty of Bioscience Engineering, Ghent University, Coupure Links 653, 9000 Ghent (Belgium); Van Acker, Joris, E-mail: Joris.VanAcker@UGent.be [UGCT-Woodlab-UGent, Department of Forest and Water Management, Faculty of Bioscience Engineering, Ghent University, Coupure Links 653, 9000 Ghent (Belgium); Cnudde, Veerle, E-mail: Veerle.Cnudde@UGent.be [UGCT-SGIG, Department of Geology and Soil Science, Faculty of Sciences, Ghent University, Krijgslaan 281, S8, 9000 Ghent (Belgium); Van Hoorebeke, Luc, E-mail: Luc.VanHoorebeke@UGent.be [UGCT-Department of Physics and Astronomy, Faculty of Sciences, Ghent University, Proeftuinstraat 86, 9000 Ghent (Belgium)

    2014-04-01

    This paper describes two X-ray micro-CT scanners which were recently developed to extend the experimental possibilities of microtomography research at the Centre for X-ray Tomography ( (www.ugct.ugent.be)) of the Ghent University (Belgium). The first scanner, called Nanowood, is a wide-range CT scanner with two X-ray sources (160 kV{sub max}) and two detectors, resolving features down to 0.4 μm in small samples, but allowing samples up to 35 cm to be scanned. This is a sample size range of 3 orders of magnitude, making this scanner well suited for imaging multi-scale materials such as wood, stone, etc. Besides the traditional cone-beam acquisition, Nanowood supports helical acquisition, and it can generate images with significant phase-contrast contributions. The second scanner, known as the Environmental micro-CT scanner (EMCT), is a gantry based micro-CT scanner with variable magnification for scanning objects which are not easy to rotate in a standard micro-CT scanner, for example because they are physically connected to external experimental hardware such as sensor wiring, tubing or others. This scanner resolves 5 μm features, covers a field-of-view of about 12 cm wide with an 80 cm vertical travel range. Both scanners will be extensively described and characterized, and their potential will be demonstrated with some key application results.

  7. Recent micro-CT scanner developments at UGCT

    International Nuclear Information System (INIS)

    Dierick, Manuel; Van Loo, Denis; Masschaele, Bert; Van den Bulcke, Jan; Van Acker, Joris; Cnudde, Veerle; Van Hoorebeke, Luc

    2014-01-01

    This paper describes two X-ray micro-CT scanners which were recently developed to extend the experimental possibilities of microtomography research at the Centre for X-ray Tomography ( (www.ugct.ugent.be)) of the Ghent University (Belgium). The first scanner, called Nanowood, is a wide-range CT scanner with two X-ray sources (160 kV max ) and two detectors, resolving features down to 0.4 μm in small samples, but allowing samples up to 35 cm to be scanned. This is a sample size range of 3 orders of magnitude, making this scanner well suited for imaging multi-scale materials such as wood, stone, etc. Besides the traditional cone-beam acquisition, Nanowood supports helical acquisition, and it can generate images with significant phase-contrast contributions. The second scanner, known as the Environmental micro-CT scanner (EMCT), is a gantry based micro-CT scanner with variable magnification for scanning objects which are not easy to rotate in a standard micro-CT scanner, for example because they are physically connected to external experimental hardware such as sensor wiring, tubing or others. This scanner resolves 5 μm features, covers a field-of-view of about 12 cm wide with an 80 cm vertical travel range. Both scanners will be extensively described and characterized, and their potential will be demonstrated with some key application results

  8. Rectangular drift tube characteristics

    International Nuclear Information System (INIS)

    Denisov, D.S.; Musienko, Yu.V.

    1985-01-01

    Results on the study of the characteristics of a 50 x 100 mm aluminium drift tube are presented. The tube was filled with argon-methane and argon-isobutane mixtures. With 16 per cent methane concentration the largest deviation from a linear relation between the drift time and the drift path over 50 mm is less than 2 mm. The tube filled with argon-isobutane mixture is capable of operating in a limited streamer mode

  9. Micro pan-tilter and focusing mechanism; Micro shikakuyo shisen henko kiko

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-03-01

    The micro pan-tilter and focusing mechanism can adjust focuses while changing freely the visual axis by using a super small CCD micro camera of 9.2 mm in a diameter times 27 mm in length, and contains a camera control unit (CCU) in this size. Many functions of a camera with a tripod head are concentrated into a size 1/10 of that of conventional cameras. The mechanism has been developed for a micro robot to inspect interior of small pipes in devices such as heat exchangers in a power plant. Future application is expected to medical endoscopes and portable information devices. This mechanism observes forward distant view and side wall short-distance view with the maximum resolution of 20 {mu}m by coordinated operation of three high-torque static power drive motors (with minimum outer diameter of 2.5 mm) fabricated by using the micromachine technology. Auto-focusing is also possible. The hybrid IC built-ion CCU has been realized by using the three-dimensional high-density mounting technology. Part of this research and development is performed under the industrial science technology research and development institution established by the Agency of Industrial Science and Technology of the Ministry of International Trade and Industry. (translated by NEDO)

  10. Study on the flow nonuniformity in a high capacity Stirling pulse tube cryocooler

    Science.gov (United States)

    You, X.; Zhi, X.; Duan, C.; Jiang, X.; Qiu, L.; Li, J.

    2017-12-01

    High capacity Stirling-type pulse tube cryocoolers (SPTC) have promising applications in high temperature superconductive motor and gas liquefaction. However, with the increase of cooling capacity, its performance deviates from well-accepted one-dimensional model simulation, such as Sage and Regen, mainly due to the strong field nonuniformity. In this study, several flow straighteners placed at both ends of the pulse tube are investigated to improve the flow distribution. A two-dimensional model of the pulse tube based on the computational fluid dynamics (CFD) method has been built to study the flow distribution of the pulse tube with different flow straighteners including copper screens, copper slots, taper transition and taper stainless slot. A SPTC set-up which has more than one hundred Watts cooling power at 80 K has been built and tested. The flow straighteners mentioned above have been applied and tested. The results show that with the best flow straightener the cooling performance of the SPTC can be significantly improved. Both CFD simulation and experiment show that the straighteners have impacts on the flow distribution and the performance of the high capacity SPTC.

  11. Water-storage-tube systems. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Hemker, P.

    1981-12-24

    Passive solar collection/storage/distribution systems were surveyed, designed, fabricated, and mechanically and thermally tested. The types studied were clear and opaque fiberglass tubes, metal tubes with plastic liners, and thermosyphoning tubes. (MHR)

  12. Contamination Study of Micro Pulsed Plasma Thruster

    National Research Council Canada - National Science Library

    Kesenek, Ceylan

    2008-01-01

    .... Micro-Pulsed Plasma Thrusters (PPTs) are highly reliable and simple micro propulsion systems that will offer attitude control, station keeping, constellation flying, and drag compensation for such satellites...

  13. Syngas (CO-H2) production using high temperature micro-tubular solid oxide electrolysers

    International Nuclear Information System (INIS)

    Kleiminger, L.; Li, T.; Li, K.; Kelsall, G.H.

    2015-01-01

    Highlights: • CO 2 and/or H 2 O reduced to CO/H 2 in micro-tubular solid oxide electrolyser (MT-SOE). • MT-SOE: CO 2 , H 2 O | Ni-(ZrO 2 ) 0.92 (Y 2 O 3 ) 0.08 (YSZ) | YSZ | YSZ- La 0.8 Sr 0.2 MnO 3-δ |O 2. • −0.76 A cm −2 achieved at 1.5V and ca. 820°C for H 2 O electrolysis. • Ni wire cathode current collector gave better performance than (Ag wire+Ag paste). • C 18 O 2 in co-electrolysis could not distinguish cathodic and chemical reduction. - Abstract: CO 2 and/or H 2 O were reduced to CO/H 2 in micro-tubular solid oxide electrolysers with yttria-stabilized zirconia (YSZ) electrolyte, Ni-YSZ cermet cathode and strontium(II)-doped lanthanum manganite (LSM) oxygen-evolving anode. At 822 °C, the kinetics of CO 2 reduction were slower (ca. −0.49 A cm −2 at 1.8 V) than H 2 O reduction or co-reduction of CO 2 and H 2 O, which were comparable (ca. −0.83 to −0.77 A cm −2 at 1.8 V). Performances were improved (−0.85 and −1.1 A cm −2 for CO 2 and H 2 O electrolysis, respectively) by substituting the silver current collector with nickel and avoiding blockage of entrances to pores on the inner lumen of micro-tubes induced by silver paste applied previously to decrease contact losses. The change in current collector materials increased ohmic potential losses due to substituting the lower resistance Ag with Ni wire, but decreased electrode polarization losses by 80–93%. For co-electrolysis of CO 2 and H 2 O, isotopically-labelled C 18 O 2 was used to try to distinguish between direct cathodic reduction of CO 2 and its Ni-catalysed chemical reaction with hydrogen from reduction of steam. Unfortunately, oxygen was exchanged between C 18 O 2 and H 2 16 O, enriching oxygen-18 in the steam and substituting oxygen-16 in the carbon dioxide, so the anode off-gas isotopic fractions were meaningless. This occurred even in alumina and YSZ tubes without the micro-tubular reactor, i.e. in the absence of Ni catalyst, though not in quartz tubes

  14. Tube to tube excursive instability - sensitivities and transients

    International Nuclear Information System (INIS)

    Brown, M.; Layland, M.W.

    1980-01-01

    A simple basic analysis of excursive instability in a boiler tube shows how it depends upon operating conditions and physical properties. A detailed mathematical model of an AGR boiler is used to conduct a steady state parameter sensitivity survey. It is possible from this basis to anticipate the effects of changes in operating conditions and changes in design parameters upon tube to tube stability. Dynamic responses of tubes operating near the stability threshold are examined using a mathematical model. Simulated excursions are triggered by imparting small abrupt pressure changes on the boiler inlet pressure. The influences of the magnitude of the pressure change, waterside friction factor and gas side coupling between tubes are examined. (author)

  15. Tube-support response to tube-denting evaluation. Volume 1. Final report

    International Nuclear Information System (INIS)

    Anderson, P.L.; Hall, J.F.; Shah, P.K.; Wills, R.L.

    1983-05-01

    The response of the tube supports is one of the important considerations of tube denting in a steam generator. Investigations have indicated that damaged tube supports have the potential to distort and damage tubes. This investigation considers the response to tube denting of the Combustion Engineering type tube supports. Drilled support plates and eggcrate tube supports are tested in a model steam generator in which tube denting is induced. The experimental data is used to verify and refine analytical predictor models developed using finite element techniques. It was found that analytical models underpredicted the deformations of the tube supports and appropriate modifications to enhance the predictive capability are identified. Non-destructive examination methods are evaluated for application to operating steam generators. It was found that the standard eddy current and profilometry techniques are acceptable methods for determining tube deformations, but these techniques are not adequate to assess tube support damage. Radiography is judged to be the best available means of determining the extent and progression of damage in tube supports

  16. Manufacture of tube billets for fuel cans by vacuum centrifugal casting

    International Nuclear Information System (INIS)

    Zelenskij, V.F.; Neklyudov, I.M.; Chernyj, B.P.

    1989-01-01

    Vacuum device for induction melting with centrifugal casting in the ingot mold with rotation vertical or horisontal axis is presented. Removing and grinding of nonmetallic inclusions are realized by selection of casting conditions and of chemically active reducer, sound metal with high ductility is obtained. Data on micro- and macrostructure of casted tube billets made of 08Kh18N10T and 06Kh16H15M3B stainless steels, designed for manufacture of fuel cans are presented

  17. a Study of Ultrasonic Wave Propagation Through Parallel Arrays of Immersed Tubes

    Science.gov (United States)

    Cocker, R. P.; Challis, R. E.

    1996-06-01

    Tubular array structures are a very common component in industrial heat exchanging plant and the non-destructive testing of these arrays is essential. Acoustic methods using microphones or ultrasound are attractive but require a thorough understanding of the acoustic properties of tube arrays. This paper details the development and testing of a small-scale physical model of a tube array to verify the predictions of a theoretical model for acoustic propagation through tube arrays developed by Heckl, Mulholland, and Huang [1-5] as a basis for the consideration of small-scale physical models in the development of non-destructive testing procedures for tube arrays. Their model predicts transmission spectra for plane waves incident on an array of tubes arranged in straight rows. Relative transmission is frequency dependent with bands of high and low attenuation caused by resonances within individual tubes and between tubes in the array. As the number of rows in the array increases the relative transmission spectrum becomes more complex, with increasingly well-defined bands of high and low attenuation. Diffraction of acoustic waves with wavelengths less than the tube spacing is predicted and appears as step reductions in the transmission spectrum at frequencies corresponding to integer multiples of the tube spacing. Experiments with the physical model confirm the principle features of the theoretical treatment.

  18. Properties and application study of Inconel alloy tube made in China

    International Nuclear Information System (INIS)

    Yang Xiang; Su Xingwan; Wen Yan

    1997-01-01

    The mech-physical properties and the corrosion resistance properties of the SG tube of Inconel alloy made in China under any conditions are briefly presented, and the test and research for bending and expending the tubes have been performed. In the process of corrosion experiments the Inconel alloy tubes were compared with that of the same kind of materials made in foreign countries. The Inconel alloy tubes have better stress corrosion resistance cracking prosperities than Inconel 600 and Incoloy 800 when they were in the solutions which contained high concentrated chlorine ion and alkali at high temperature

  19. Analysis and experimental study on the effect of a resonant tube on the performance of acoustic levitation devices

    OpenAIRE

    Hai Jiang; Jianfang Liu; Qingqing Lv; Shoudong Gu; Xiaoyang Jiao; Minjiao Li; Shasha Zhang

    2016-01-01

    The influence of a resonant tube on the performance of acoustic standing wave-based levitation device (acoustic levitation device hereinafter) is studied by analyzing the acoustic pressure and levitation force of four types of acoustic levitation devices without a resonance tube and with resonance tubes of different radii R using ANSYS and MATLAB. Introducing a resonance tube either enhances or weakens the levitation strength of acoustic levitation device, depending on the resonance tube radi...

  20. Tracking differentiating neural progenitors in pluripotent cultures using microRNA-regulated lentiviral vectors.

    Science.gov (United States)

    Sachdeva, Rohit; Jönsson, Marie E; Nelander, Jenny; Kirkeby, Agnete; Guibentif, Carolina; Gentner, Bernhard; Naldini, Luigi; Björklund, Anders; Parmar, Malin; Jakobsson, Johan

    2010-06-22

    In this study, we have used a microRNA-regulated lentiviral reporter system to visualize and segregate differentiating neuronal cells in pluripotent cultures. Efficient suppression of transgene expression, specifically in undifferentiated pluripotent cells, was achieved by using a lentiviral vector expressing a fluorescent reporter gene regulated by microRNA-292. Using this strategy, it was possible to track progeny from murine ES, human ES cells, and induced pluripotent stem cells as they differentiated toward the neural lineage. In addition, this strategy was successfully used to FACS purify neuronal progenitors for molecular analysis and transplantation. FACS enrichment reduced tumor formation and increased survival of ES cell-derived neuronal progenitors after transplantation. The properties and versatility of the microRNA-regulated vectors allows broad use of these vectors in stem cell applications.