  1. SU-E-I-53: Comparison of Kerma-Area-Product Between the Micro-Angiographic Fluoroscope (MAF) and a Flat Panel Detector (FPD) as Used in Neuro-Endovascular Procedures

    International Nuclear Information System (INIS)

    Vijayan, S; Rana, V; Nagesh, S Setlur; Xiong, Z; Rudin, S; Bednarek, D

    2015-01-01

    Purpose: To determine the reduction of integral dose to the patient when using the micro-angiographic fluoroscope (MAF) compared to when using the standard flat-panel detector (FPD) for the techniques used during neurointerventional procedures. Methods: The MAF is a small field-of-view, high resolution x-ray detector which captures 1024 x 1024 pixels with an effective pixel size of 35μm and is capable of real-time imaging up to 30 frames per second. The MAF was used in neuro-interventions during those parts of the procedure when high resolution was needed and the FPD was used otherwise. The technique parameters were recorded when each detector was used and the kerma-area-product (KAP) per image frame was determined. KAP values were calculated for seven neuro interventions using premeasured calibration files of output as a function of kVp and beam filtration and included the attenuation of the patient table for the frontal projections to be more representative of integral patient dose. The air kerma at the patient entrance was multiplied by the beam area at that point to obtain the KAP values. The ranges of KAP values per frame were determined for the range of technique parameters used during the clinical procedures. To appreciate the benefit of the higher MAF resolution in the region of interventional activity, DA technique parameters were generally used with the MAF. Results: The lowest and highest values of KAP per frame for the MAF in DA mode were 4 and 50 times lower, respectively, compared to those of the FPD in pulsed fluoroscopy mode. Conclusion: The MAF was used in those parts of the clinical procedures when high resolution and image quality was essential. The integral patient dose as represented by the KAP value was substantially lower when using the MAF than when using the FPD due to the much smaller volume of tissue irradiated. This research was supported in part by Toshiba Medical Systems Corporation and NIH Grant R01EB002873

  2. SU-E-I-53: Comparison of Kerma-Area-Product Between the Micro-Angiographic Fluoroscope (MAF) and a Flat Panel Detector (FPD) as Used in Neuro-Endovascular Procedures

    Energy Technology Data Exchange (ETDEWEB)

    Vijayan, S; Rana, V; Nagesh, S Setlur; Xiong, Z; Rudin, S; Bednarek, D [Toshiba Stroke and Vascular Research Center, University at Buffalo, Buffalo, NY (United States)

    2015-06-15

    Purpose: To determine the reduction of integral dose to the patient when using the micro-angiographic fluoroscope (MAF) compared to when using the standard flat-panel detector (FPD) for the techniques used during neurointerventional procedures. Methods: The MAF is a small field-of-view, high resolution x-ray detector which captures 1024 x 1024 pixels with an effective pixel size of 35μm and is capable of real-time imaging up to 30 frames per second. The MAF was used in neuro-interventions during those parts of the procedure when high resolution was needed and the FPD was used otherwise. The technique parameters were recorded when each detector was used and the kerma-area-product (KAP) per image frame was determined. KAP values were calculated for seven neuro interventions using premeasured calibration files of output as a function of kVp and beam filtration and included the attenuation of the patient table for the frontal projections to be more representative of integral patient dose. The air kerma at the patient entrance was multiplied by the beam area at that point to obtain the KAP values. The ranges of KAP values per frame were determined for the range of technique parameters used during the clinical procedures. To appreciate the benefit of the higher MAF resolution in the region of interventional activity, DA technique parameters were generally used with the MAF. Results: The lowest and highest values of KAP per frame for the MAF in DA mode were 4 and 50 times lower, respectively, compared to those of the FPD in pulsed fluoroscopy mode. Conclusion: The MAF was used in those parts of the clinical procedures when high resolution and image quality was essential. The integral patient dose as represented by the KAP value was substantially lower when using the MAF than when using the FPD due to the much smaller volume of tissue irradiated. This research was supported in part by Toshiba Medical Systems Corporation and NIH Grant R01EB002873.

  3. Design considerations for a new, high resolution Micro-Angiographic Fluoroscope based on a CMOS sensor (MAF-CMOS).

    Science.gov (United States)

    Loughran, Brendan; Swetadri Vasan, S N; Singh, Vivek; Ionita, Ciprian N; Jain, Amit; Bednarek, Daniel R; Titus, Albert; Rudin, Stephen

    2013-03-06

    The detectors that are used for endovascular image-guided interventions (EIGI), particularly for neurovascular interventions, do not provide clinicians with adequate visualization to ensure the best possible treatment outcomes. Developing an improved x-ray imaging detector requires the determination of estimated clinical x-ray entrance exposures to the detector. The range of exposures to the detector in clinical studies was found for the three modes of operation: fluoroscopic mode, high frame-rate digital angiographic mode (HD fluoroscopic mode), and DSA mode. Using these estimated detector exposure ranges and available CMOS detector technical specifications, design requirements were developed to pursue a quantum limited, high resolution, dynamic x-ray detector based on a CMOS sensor with 50 μm pixel size. For the proposed MAF-CMOS, the estimated charge collected within the full exposure range was found to be within the estimated full well capacity of the pixels. Expected instrumentation noise for the proposed detector was estimated to be 50-1,300 electrons. Adding a gain stage such as a light image intensifier would minimize the effect of the estimated instrumentation noise on total image noise but may not be necessary to ensure quantum limited detector operation at low exposure levels. A recursive temporal filter may decrease the effective total noise by 2 to 3 times, allowing for the improved signal to noise ratios at the lowest estimated exposures despite consequent loss in temporal resolution. This work can serve as a guide for further development of dynamic x-ray imaging prototypes or improvements for existing dynamic x-ray imaging systems.

  4. Evaluation and Comparison of High-Resolution (HR) and High-Light (HL) Phosphors in the Micro-Angiographic Fluoroscope (MAF) using Generalized Linear Systems Analyses (GMTF, GDQE) that include the Effect of Scatter, Magnification and Detector Characteristics.

    Science.gov (United States)

    Gupta, Sandesh K; Jain, Amit; Bednarek, Daniel R; Rudin, Stephen

    2011-01-01

    In this study, we evaluated the imaging characteristics of the high-resolution, high-sensitivity micro-angiographic fluoroscope (MAF) with 35-micron pixel-pitch when used with different commercially-available 300 micron thick phosphors: the high resolution (HR) and high light (HL) from Hamamatsu. The purpose of this evaluation was to see if the HL phosphor with its higher screen efficiency could be replaced with the HR phosphor to achieve improved resolution without an increase in noise resulting from the HR's decreased light-photon yield. We designated the detectors MAF-HR and MAF-HL and compared them with a standard flat panel detector (FPD) (194 micron pixel pitch and 600 micron thick CsI(Tl)). For this comparison, we used the generalized linear-system metrics of GMTF, GNNPS and GDQE which are more realistic measures of total system performance since they include the effect of scattered radiation, focal spot distribution, and geometric un-sharpness. Magnifications (1.05-1.15) and scatter fractions (0.28 and 0.33) characteristic of a standard head phantom were used. The MAF-HR performed significantly better than the MAF-HL at high spatial frequencies. The ratio of GMTF and GDQE of the MAF-HR compared to the MAF-HL at 3(6) cycles/mm was 1.45(2.42) and 1.23(2.89), respectively. Despite significant degradation by inclusion of scatter and object magnification, both MAF-HR and MAF-HL provide superior performance over the FPD at higher spatial frequencies with similar performance up to the FPD's Nyquist frequency of 2.5 cycles/mm. Both substantially higher resolution and improved GDQE can be achieved with the MAF using the HR phosphor instead of the HL phosphor.

  5. WE-G-204-05: Relative Object Detectability Evaluation of a New High Resolution A-Se Direct Detection System Compared to Indirect Micro-Angiographic Fluoroscopic (MAF) Detectors

    International Nuclear Information System (INIS)

    Russ, M; Nagesh, S Setlur; Ionita, C; Bednarek, D; Rudin, S; Scott, C; Karim, K

    2015-01-01

    Purpose: To evaluate the task specific imaging performance of a new 25µm pixel pitch, 1000µm thick amorphous selenium direct detection system with CMOS readout for typical angiographic exposure parameters using the relative object detectability (ROD) metric. Methods: The ROD metric uses a simulated object function weighted at each spatial frequency by the detectors’ detective quantum efficiency (DQE), which is an intrinsic performance metric. For this study, the simulated objects were aluminum spheres of varying diameter (0.05–0.6mm). The weighted object function is then integrated over the full range of detectable frequencies inherent to each detector, and a ratio is taken of the resulting value for two detectors. The DQE for the 25µm detector was obtained from a simulation of a proposed a-Se detector using an exposure of 200µR for a 50keV x-ray beam. This a-Se detector was compared to two microangiographic fluoroscope (MAF) detectors [the MAF-CCD with pixel size of 35µm and Nyquist frequency of 14.2 cycles/mm and the MAF-CMOS with pixel size of 75µm and Nyquist frequency of 6.6 cycles/mm] and a standard flat-panel detector (FPD with pixel size of 194µm and Nyquist frequency of 2.5cycles/mm). Results: ROD calculations indicated vastly superior performance by the a-Se detector in imaging small aluminum spheres. For the 50µm diameter sphere, the ROD values for the a-Se detector compared to the MAF-CCD, the MAF-CMOS, and the FPD were 7.3, 9.3 and 58, respectively. Detector performance in the low frequency regime was dictated by each detector’s DQE(0) value. Conclusion: The a-Se with CMOS readout is unique and appears to have distinctive advantages of incomparable high resolution, low noise, no readout lag, and expandable design. The a-Se direct detection system will be a powerful imaging tool in angiography, with potential break-through applications in diagnosis and treatment of neuro-vascular disease. Supported by NIH Grant: 2R01EB002873 and an

  6. WE-G-204-05: Relative Object Detectability Evaluation of a New High Resolution A-Se Direct Detection System Compared to Indirect Micro-Angiographic Fluoroscopic (MAF) Detectors

    Energy Technology Data Exchange (ETDEWEB)

    Russ, M; Nagesh, S Setlur; Ionita, C; Bednarek, D; Rudin, S [Toshiba Stroke and Vascular Research Center, University at Buffalo (SUNY), Buffalo, NY (United States); Scott, C; Karim, K [University of Waterloo, Waterloo, ON (Canada)

    2015-06-15

    Purpose: To evaluate the task specific imaging performance of a new 25µm pixel pitch, 1000µm thick amorphous selenium direct detection system with CMOS readout for typical angiographic exposure parameters using the relative object detectability (ROD) metric. Methods: The ROD metric uses a simulated object function weighted at each spatial frequency by the detectors’ detective quantum efficiency (DQE), which is an intrinsic performance metric. For this study, the simulated objects were aluminum spheres of varying diameter (0.05–0.6mm). The weighted object function is then integrated over the full range of detectable frequencies inherent to each detector, and a ratio is taken of the resulting value for two detectors. The DQE for the 25µm detector was obtained from a simulation of a proposed a-Se detector using an exposure of 200µR for a 50keV x-ray beam. This a-Se detector was compared to two microangiographic fluoroscope (MAF) detectors [the MAF-CCD with pixel size of 35µm and Nyquist frequency of 14.2 cycles/mm and the MAF-CMOS with pixel size of 75µm and Nyquist frequency of 6.6 cycles/mm] and a standard flat-panel detector (FPD with pixel size of 194µm and Nyquist frequency of 2.5cycles/mm). Results: ROD calculations indicated vastly superior performance by the a-Se detector in imaging small aluminum spheres. For the 50µm diameter sphere, the ROD values for the a-Se detector compared to the MAF-CCD, the MAF-CMOS, and the FPD were 7.3, 9.3 and 58, respectively. Detector performance in the low frequency regime was dictated by each detector’s DQE(0) value. Conclusion: The a-Se with CMOS readout is unique and appears to have distinctive advantages of incomparable high resolution, low noise, no readout lag, and expandable design. The a-Se direct detection system will be a powerful imaging tool in angiography, with potential break-through applications in diagnosis and treatment of neuro-vascular disease. Supported by NIH Grant: 2R01EB002873 and an

  7. Registration of angiographic image on real-time fluoroscopic image for image-guided percutaneous coronary intervention.

    Science.gov (United States)

    Kim, Dongkue; Park, Sangsoo; Jeong, Myung Ho; Ryu, Jeha

    2018-02-01

    In percutaneous coronary intervention (PCI), cardiologists must study two different X-ray image sources: a fluoroscopic image and an angiogram. Manipulating a guidewire while alternately monitoring the two separate images on separate screens requires a deep understanding of the anatomy of coronary vessels and substantial training. We propose 2D/2D spatiotemporal image registration of the two images in a single image in order to provide cardiologists with enhanced visual guidance in PCI. The proposed 2D/2D spatiotemporal registration method uses a cross-correlation of two ECG series in each image to temporally synchronize two separate images and register an angiographic image onto the fluoroscopic image. A guidewire centerline is then extracted from the fluoroscopic image in real time, and the alignment of the centerline with vessel outlines of the chosen angiographic image is optimized using the iterative closest point algorithm for spatial registration. A proof-of-concept evaluation with a phantom coronary vessel model with engineering students showed an error reduction rate greater than 74% on wrong insertion to nontarget branches compared to the non-registration method and more than 47% reduction in the task completion time in performing guidewire manipulation for very difficult tasks. Evaluation with a small number of experienced doctors shows a potentially significant reduction in both task completion time and error rate for difficult tasks. The total registration time with real procedure X-ray (angiographic and fluoroscopic) images takes [Formula: see text] 60 ms, which is within the fluoroscopic image acquisition rate of 15 Hz. By providing cardiologists with better visual guidance in PCI, the proposed spatiotemporal image registration method is shown to be useful in advancing the guidewire to the coronary vessel branches, especially those difficult to insert into.

  8. Quantitative comparison using Generalized Relative Object Detectability (G-ROD) metrics of an amorphous selenium detector with high resolution Microangiographic Fluoroscopes (MAF) and standard flat panel detectors (FPD).

    Science.gov (United States)

    Russ, M; Shankar, A; Jain, A; Setlur Nagesh, S V; Ionita, C N; Scott, C; Karim, K S; Bednarek, D R; Rudin, S

    2016-02-27

    A novel amorphous selenium (a-Se) direct detector with CMOS readout has been designed, and relative detector performance investigated. The detector features include a 25 μ m pixel pitch, and 1000 μ m thick a-Se layer operating at 10V/ μ m bias field. A simulated detector DQE was determined, and used in comparative calculations of the Relative Object Detectability (ROD) family of prewhitening matched-filter (PWMF) observer and non-prewhitening matched filter (NPWMF) observer model metrics to gauge a-Se detector performance against existing high resolution micro-angiographic fluoroscopic (MAF) detectors and a standard flat panel detector (FPD). The PWMF-ROD or ROD metric compares two x-ray imaging detectors in their relative abilities in imaging a given object by taking the integral over spatial frequencies of the Fourier transform of the detector DQE weighted by an object function, divided by the comparable integral for a different detector. The generalized-ROD (G-ROD) metric incorporates clinically relevant parameters (focal-spot size, magnification, and scatter) to show the degradation in imaging performance for detectors that are part of an imaging chain. Preliminary ROD calculations using simulated spheres as the object predicted superior imaging performance by the a-Se detector as compared to existing detectors. New PWMF-G-ROD and NPWMF-G-ROD results still indicate better performance by the a-Se detector in an imaging chain over all sphere sizes for various focal spot sizes and magnifications, although a-Se performance advantages were degraded by focal spot blurring. Nevertheless, the a-Se technology has great potential to provide breakthrough abilities such as visualization of fine details including of neuro-vascular perforator vessels and of small vascular devices.

  9. SU-E-CAMPUS-I-04: Automatic Skin-Dose Mapping for An Angiographic System with a Region-Of-Interest, High-Resolution Detector

    Energy Technology Data Exchange (ETDEWEB)

    Vijayan, S; Rana, V [Department of Physiology and Biophysics, Toshiba Stroke and Vascular Research Center (United States); Setlur Nagesh, S [Toshiba Stroke and Vascular Research Center (United States); Ionita, C [Department of Biomedical Engineering, University at Buffalo (State University of New York), Buffalo, NY (United States); Rudin, S [Department of Radiology, Department of Physiology and Biophysics, Toshiba Stroke and Vascular Research Center, Department of Biomedical Engineering, University at Buffalo (State University of New York), Buffalo, NY (United States); Bednarek, D [Department of Radiology, Department of Physiology and Biophysics, Toshiba Stroke and Vascular Research Center (United States)

    2014-06-15

    Purpose: Our real-time skin dose tracking system (DTS) has been upgraded to monitor dose for the micro-angiographic fluoroscope (MAF), a high-resolution, small field-of-view x-ray detector. Methods: The MAF has been mounted on a changer on a clinical C-Arm gantry so it can be used interchangeably with the standard flat-panel detector (FPD) during neuro-interventional procedures when high resolution is needed in a region-of-interest. To monitor patient skin dose when using the MAF, our DTS has been modified to automatically account for the change in scatter for the very small MAF FOV and to provide separated dose distributions for each detector. The DTS is able to provide a color-coded mapping of the cumulative skin dose on a 3D graphic model of the patient. To determine the correct entrance skin exposure to be applied by the DTS, a correction factor was determined by measuring the exposure at the entrance surface of a skull phantom with an ionization chamber as a function of entrance beam size for various beam filters and kVps. Entrance exposure measurements included primary radiation, patient backscatter and table forward scatter. To allow separation of the dose from each detector, a parameter log is kept that allows a replay of the procedure exposure events and recalculation of the dose components.The graphic display can then be constructed showing the dose distribution from the MAF and FPD separately or together. Results: The DTS is able to provide separate displays of dose for the MAF and FPD with field-size specific scatter corrections. These measured corrections change from about 49% down to 10% when changing from the FPD to the MAF. Conclusion: The upgraded DTS allows identification of the patient skin dose delivered when using each detector in order to achieve improved dose management as well as to facilitate peak skin-dose reduction through dose spreading. Research supported in part by Toshiba Medical Systems Corporation and NIH Grants R43FD0158401, R44FD

  10. Rotational micro-CT using a clinical C-arm angiography gantry

    International Nuclear Information System (INIS)

    Patel, V.; Hoffmann, K. R.; Ionita, C. N.; Keleshis, C.; Bednarek, D. R.; Rudin, S.

    2008-01-01

    Rotational angiography (RA) gantries are used routinely to acquire sequences of projection images of patients from which 3D renderings of vascular structures are generated using Feldkamp cone-beam reconstruction algorithms. However, these systems have limited resolution ( 10 lp/mm) but to date have relied either on rotating object imaging or small bore geometry for small animal imaging, and thus are not used for clinical imaging. The authors report here the development and use of a 3D rotational micro-angiography (RMA) system created by mounting a micro-angiographic fluoroscope (MAF) [35 μm pixel, resolution >10 lp/mm, field of view (FOV)=3.6 cm] on a standard clinical FPD-based RA gantry (Infinix, Model RTP12303J-G9E, Toshiba Medical Systems Corp., Tustin, CA). RA image sequences are obtained using the MAF and reconstructed. To eliminate artifacts due to image truncation, lower-dose (compared to MAF acquisition) full-FOV (FFOV) FPD RA sequences (194 μm pixel, FOV=20 cm) were also obtained to complete the missing data. The RA gantry was calibrated using a helical bead phantom. To ensure high-quality high-resolution reconstruction, the high-resolution images from the MAF were aligned spatially with the lower-dose FPD images, and the pixel values in the FPD image data were scaled to match those of the MAF. Images of a rabbit with a coronary stent placed in an artery in the Circle of Willis were obtained and reconstructed. The MAF images appear well aligned with the FPD images (average correlation coefficient before and after alignment: 0.65 and 0.97, respectively) Greater details without any visible truncation artifacts are seen in 3D RMA (MAF-FPD) images than in those of the FPD alone. The FWHM of line profiles of stent struts (100 μm diameter) are approximately 192±21 and 313±38 μm for the 3D RMA and FPD data, respectively. In addition, for the dual-acquisition 3D RMA, FFOV FPD data need not be of the highest quality, and thus may be acquired at lower dose

  11. SU-D-204-05: Quantitative Comparison of a High Resolution Micro-Angiographic Fluoroscopic (MAF) Detector with a Standard Flat Panel Detector (FPD) Using the New Metric of Generalized Measured Relative Object Detectability (GM-ROD)

    Energy Technology Data Exchange (ETDEWEB)

    Russ, M; Ionita, C; Bednarek, D; Rudin, S [Toshiba Stroke and Vascular Research Center, University at Buffalo (SUNY), Buffalo, NY (United States)

    2015-06-15

    Purpose: In endovascular image-guided neuro-interventions, visualization of fine detail is paramount. For example, the ability of the interventionist to visualize the stent struts depends heavily on the x-ray imaging detector performance. Methods: A study to examine the relative performance of the high resolution MAF-CMOS (pixel size 75µm, Nyquist frequency 6.6 cycles/mm) and a standard Flat Panel Detector (pixel size 194µm, Nyquist frequency 2.5 cycles/mm) detectors in imaging a neuro stent was done using the Generalized Measured Relative Object Detectability (GM-ROD) metric. Low quantum noise images of a deployed stent were obtained by averaging 95 frames obtained by both detectors without changing other exposure or geometric parameters. The square of the Fourier transform of each image is taken and divided by the generalized normalized noise power spectrum to give an effective measured task-specific signal-to-noise ratio. This expression is then integrated from 0 to each of the detector’s Nyquist frequencies, and the GM-ROD value is determined by taking a ratio of the integrals for the MAF-CMOS to that of the FPD. The lower bound of integration can be varied to emphasize high frequencies in the detector comparisons. Results: The MAF-CMOS detector exhibits vastly superior performance over the FPD when integrating over all frequencies, yielding a GM-ROD value of 63.1. The lower bound of integration was stepped up in increments of 0.5 cycles/mm for higher frequency comparisons. As the lower bound increased, the GM-ROD value was augmented, reflecting the superior performance of the MAF-CMOS in the high frequency regime. Conclusion: GM-ROD is a versatile metric that can provide quantitative detector and task dependent comparisons that can be used as a basis for detector selection. Supported by NIH Grant: 2R01EB002873 and an equipment grant from Toshiba Medical Systems Corporation.

  12. Angiographic Guidewire with Measuring Markers: Design and Clinical Experience

    International Nuclear Information System (INIS)

    Kamei, Seiji; Ishiguchi, Tsuneo; Murata, Katsuhito; Matsuda, Joe; Ohno, Ryota; Kimura, Junko; Nakamura, Atsushi; Ohno, Kazuko; Kawamura, Toshiki; Ikeda, Mitsuru

    2006-01-01

    Purpose. We have developed an angiographic guidewire with measuring markers to determine accurately how far a guidewire is inserted within a catheter. We investigated whether use of this guidewire reduces the risk of vascular injury and the fluoroscopic time during guidewire manipulations. Methods. Four markers were put on the surface of the guidewire at 80, 100, 110, and 120 cm from the tip. The actual lengths of 54 catheters from seven manufacturers were measured and compared with the nominal lengths. Sixty consecutive patients who underwent angiography were randomized into two groups: in one group guidewires with surface markers were used (marker group) and in the other group, conventional guidewires (control group). For each guidewire insertion, the fluoroscopic time before the guidewire was pushed forward into the vessel lumen was recorded. The number of occasions on which unintentionally the guidewire had already been pushed out of the catheter at the start of fluoroscopy was also evaluated. Results. The actual lengths of all catheters were greater than the nominal lengths by 1.0-11.0 cm. Mean fluoroscopic time for each guidewire insertion was 3.3 sec in the marker group and 5.7 sec in the control group (p < 0.05). Guidewires were unintentionally pushed out of the catheters without fluoroscopy three times (3.6%), in each case in the control group. Conclusion. The guidewire with measuring markers is effective for enhancing safety and in reducing fluoroscopic radiation during angiographic procedures. It is recommended that operators be aware that actual lengths of catheters may vary significantly from the nominal lengths listed; they should be aware of this with any guidewire, but particularly with the angiographic measuring guidewire

  13. Micro-angiographic system using synchrotron radiation and conventional x-ray source for visualizing angiogenic vessels induced by cardiovascular regeneration therapy

    International Nuclear Information System (INIS)

    Mori, H.; Chiku, M.; Nishigami, K.; Tanaka, E.; Kimura, K.; Kawai, T.; Suzuki, K.; Mochizuki, R.; Okawa, Y.

    2004-01-01

    Therapeutic angiogenesis improved critical limb and myocardial ischemia in human, however, angiogenic vessels were not visualized well by conventional angiography, because of its limited spatial resolution of 200 μm. Recently, synchrotron radiation system characterized by high brightness, monochromatic and collimated nature revealed the micro-vessels of heart and lower limb in situ. We developed also an in-house microangiographic system with a relatively low cost. Limb ischemia models were made by ligature of femoral artery and treated by angiogenic growth factor genes and so on. One month after the treatment, we evaluated collateral micro-vessels by using the conventional and micro-angiographic systems. The approach was left femoral artery, and catheter was located in abdominal aorta. Iodine contrast (300 mg/ml) was injected 5 ml by 3 ml/sec with auto-injection system. The imaging was recorded by digital source in 1000 x 1000 pixels. The micro-angiographic system could detect the micro-vessels more precisely than conventional angiographic system and evaluate their function. (author)

  14. Fluoroscopic guidance of retrograde exchange of ureteral stents in women.

    Science.gov (United States)

    Chang, Ruey-Sheng; Liang, Huei-Lung; Huang, Jer-Shyung; Wang, Po-Chin; Chen, Matt Chiung-Yu; Lai, Ping-Hong; Pan, Huay-Ben

    2008-06-01

    The purpose of this study was to review our experience with fluoroscopically guided retrograde exchange of ureteral stents in women. During a 48-month period, 28 women (age range, 38-76 years) were referred to our department for retrograde exchange of a ureteral stent. The causes of urinary obstruction were tumor compression in 26 patients and benign fibrotic stricture in two patients. A large-diameter snare catheter (25-mm single loop or 18- to 35-mm triple loop) or a foreign body retrieval forceps (opening width, 11.3 mm) was used to grasp the bladder end of the stent under fluoroscopic guidance. The technique entailed replacement of a patent or occluded ureteral stent with a 0.035- or 0.018-inch guidewire with or without the aid of advancement of an angiographic sheath. A total of 54 ureteral stents were exchanged with a snare catheter in 42 cases or a forceps in 12 cases. One stent misplaced too far up the ureter was replaced successfully through antegrade percutaneous nephrostomy. Ten occluded stents, including one single-J stent, were managed with a 0.018-inch guidewire in three cases, advancement of an angiographic sheath over the occluded stent into the ureter in five cases, and recannulation of the ureteral orifice with a guidewire in two cases. No complications of massive hemorrhage, ureter perforation, or infection were encountered. With proper selection of a snare or forceps catheter, retrograde exchange of ureteral stents in women can be easily performed under fluoroscopic guidance with high technical success and a low complication rate.

  15. Variations of Patient Doses in Interventional Examinations at Different Angiographic Units

    International Nuclear Information System (INIS)

    Bor, Dogan; Toklu, Tuerkay; Olgar, Turan; Sancak, Tanzer; Cekirge, Saruhan; Onal, Baran; Bilgic, Sadik

    2006-01-01

    Purpose. We analyzed doses for various angiographic procedures using different X-ray systems in order to assess dose variations. Methods. Dose-area product (DAP), skin doses from thermoluminescent dosimeters and air kerma measurements of 308 patients (239 diagnostic and 69 interventional) were assessed for five different angiographic units. All fluoroscopic and radiographic exposure parameters were recorded online for single and multiprojection studies. Radiation outputs of each X-ray system were also measured for all the modes of exposure using standard protocols for such measurements. Results. In general, the complexity of the angiographic procedure was found to be the most important reason for high radiation doses. Skill of the radiologist, management of the exposure parameters and calibration of the system are the other factors to be considered. Lateral cerebral interventional studies carry the highest risk for deterministic effects on the lens of the eye. Effective doses were calculated from DAP measurements and maximum fatal cancer risk factors were found for carotid studies. Conclusions. Interventional radiologists should measure patient doses for their examinations. If there is a lack of necessary instrumentation for this purpose, then published dose reports should be used in order to predict the dose levels from some of the exposure parameters. Patient dose information should include not only the measured quantity but also the measured radiation output of the X-ray unit and exposure parameters used during radiographic and fluoroscopic exposures

  16. The association of age-related maculopathy susceptibility 2 (ARMS2) and complement factor H (CFH) variants with two angiographic subtypes of polypoidal choroidal vasculopathy.

    Science.gov (United States)

    Miki, Akiko; Honda, Shigeru; Kondo, Naoshi; Negi, Akira

    2013-09-01

    To compare the association of age-related maculopathy susceptibility 2 (ARMS2) and complement factor H (CFH) variants between two different angiographic phenotypes of polypoidal choroidal vasculopathy (PCV). We included 175 Japanese patients with PCV and 150 age- and sex-matched controls. PCV was classified into two phenotypes (Type 1 and Type 2) according to the presence or absence of the feeding vessels found in indocyanine-green angiography. The single nucleotide polymorphism (SNP) at rs10490924 (A69S) in ARMS2 and rs800292 (I62V), rs1061170 (Y402H) in the CFH region were genotyped using the TaqMan assay. The minor allele frequency (MAF) of rs10490924 was significantly different between Type 1 PCV (n = 81) and control (p < 0.0001), while no difference was found between Type 2 PCV (n = 94) and control (p = 0.20). The MAF of rs800292 was significantly different between each type of PCV and control (p < 0.0001 and 0.0001 for Type 1 versus control and Type 2 versus control, respectively). The MAF of rs1061170 was not significantly different between either type of PCV and control (p = 0.084 and 0.15, respectively). There may be significantly different associations in the genetic variants of ARMS2 between two angiographic phenotypes of PCV.

  17. LabVIEW Graphical User Interface for a New High Sensitivity, High Resolution Micro-Angio-Fluoroscopic and ROI-CBCT System.

    Science.gov (United States)

    Keleshis, C; Ionita, Cn; Yadava, G; Patel, V; Bednarek, Dr; Hoffmann, Kr; Verevkin, A; Rudin, S

    2008-01-01

    A graphical user interface based on LabVIEW software was developed to enable clinical evaluation of a new High-Sensitivity Micro-Angio-Fluoroscopic (HSMAF) system for real-time acquisition, display and rapid frame transfer of high-resolution region-of-interest images. The HSMAF detector consists of a CsI(Tl) phosphor, a light image intensifier (LII), and a fiber-optic taper coupled to a progressive scan, frame-transfer, charged-coupled device (CCD) camera which provides real-time 12 bit, 1k × 1k images capable of greater than 10 lp/mm resolution. Images can be captured in continuous or triggered mode, and the camera can be programmed by a computer using Camera Link serial communication. A graphical user interface was developed to control the camera modes such as gain and pixel binning as well as to acquire, store, display, and process the images. The program, written in LabVIEW, has the following capabilities: camera initialization, synchronized image acquisition with the x-ray pulses, roadmap and digital subtraction angiography acquisition (DSA), flat field correction, brightness and contrast control, last frame hold in fluoroscopy, looped playback of the acquired images in angiography, recursive temporal filtering and LII gain control. Frame rates can be up to 30 fps in full-resolution mode. The user friendly implementation of the interface along with the high framerate acquisition and display for this unique high-resolution detector should provide angiographers and interventionalists with a new capability for visualizing details of small vessels and endovascular devices such as stents and hence enable more accurate diagnoses and image guided interventions. (Support: NIH Grants R01NS43924, R01EB002873).

  18. A theoretical and experimental evaluation of the microangiographic fluoroscope: A high-resolution region-of-interest x-ray imager

    International Nuclear Information System (INIS)

    Jain, Amit; Bednarek, D. R.; Ionita, Ciprian; Rudin, S.

    2011-01-01

    Purpose: The increasing need for better image quality and high spatial resolution for successful endovascular image-guided interventions (EIGIs) and the inherent limitations of the state-of-the-art detectors provide motivation to develop a detector system tailored to the specific, demanding requirements of neurointerventional applications.Method: A microangiographic fluoroscope (MAF) was developed to serve as a high-resolution, region-of-interest (ROI) x-ray imaging detector in conjunction with large lower-resolution full field-of-view (FOV) state-of-the-art x-ray detectors. The newly developed MAF is an indirect x-ray imaging detector capable of providing real-time images (30 frames per second) with high-resolution, high sensitivity, no lag and low instrumentation noise. It consists of a CCD camera coupled to a Gen 2 dual-stage microchannel plate light image intensifier (LII) through a fiber-optic taper. A 300 μm thick CsI(Tl) phosphor serving as the front end is coupled to the LII. The LII is the key component of the MAF and the large variable gain provided by it enables the MAF to operate as a quantum-noise-limited detector for both fluoroscopy and angiography. Results: The linear cascade model was used to predict the theoretical performance of the MAF, and the theoretical prediction showed close agreement with experimental findings. Linear system metrics such as MTF and DQE were used to gauge the detector performance up to 10 cycles/mm. The measured zero frequency DQE(0) was 0.55 for an RQA5 spectrum. A total of 21 stages were identified for the whole imaging chain and each stage was characterized individually. Conclusions: The linear cascade model analysis provides insight into the imaging chain and may be useful for further development of the MAF detector. The preclinical testing of the prototype detector in animal procedures is showing encouraging results and points to the potential for significant impact on EIGIs when used in conjunction with a state

  19. Generalized two-dimensional (2D) linear system analysis metrics (GMTF, GDQE) for digital radiography systems including the effect of focal spot, magnification, scatter, and detector characteristics.

    Science.gov (United States)

    Jain, Amit; Kuhls-Gilcrist, Andrew T; Gupta, Sandesh K; Bednarek, Daniel R; Rudin, Stephen

    2010-03-01

    The MTF, NNPS, and DQE are standard linear system metrics used to characterize intrinsic detector performance. To evaluate total system performance for actual clinical conditions, generalized linear system metrics (GMTF, GNNPS and GDQE) that include the effect of the focal spot distribution, scattered radiation, and geometric unsharpness are more meaningful and appropriate. In this study, a two-dimensional (2D) generalized linear system analysis was carried out for a standard flat panel detector (FPD) (194-micron pixel pitch and 600-micron thick CsI) and a newly-developed, high-resolution, micro-angiographic fluoroscope (MAF) (35-micron pixel pitch and 300-micron thick CsI). Realistic clinical parameters and x-ray spectra were used. The 2D detector MTFs were calculated using the new Noise Response method and slanted edge method and 2D focal spot distribution measurements were done using a pin-hole assembly. The scatter fraction, generated for a uniform head equivalent phantom, was measured and the scatter MTF was simulated with a theoretical model. Different magnifications and scatter fractions were used to estimate the 2D GMTF, GNNPS and GDQE for both detectors. Results show spatial non-isotropy for the 2D generalized metrics which provide a quantitative description of the performance of the complete imaging system for both detectors. This generalized analysis demonstrated that the MAF and FPD have similar capabilities at lower spatial frequencies, but that the MAF has superior performance over the FPD at higher frequencies even when considering focal spot blurring and scatter. This 2D generalized performance analysis is a valuable tool to evaluate total system capabilities and to enable optimized design for specific imaging tasks.

  20. A common variant of MAF/c-MAF, transcriptional factor gene in the kidney, is associated with gout susceptibility.

    Science.gov (United States)

    Higashino, Toshihide; Matsuo, Hirotaka; Okada, Yukinori; Nakashima, Hiroshi; Shimizu, Seiko; Sakiyama, Masayuki; Tadokoro, Shin; Nakayama, Akiyoshi; Kawaguchi, Makoto; Komatsu, Mako; Hishida, Asahi; Nakatochi, Masahiro; Ooyama, Hiroshi; Imaki, Junko; Shinomiya, Nariyoshi

    2018-01-01

    Gout is a multifactorial disease characterized by acute inflammatory arthritis, and it is caused as a consequence of hyperuricemia. A recent meta-analysis of genome-wide association studies has newly identified the relationship between serum uric acid (SUA) levels and rs889472, a single nucleotide polymorphism of musculoaponeurotic fibrosarcoma oncogene (MAF/c-MAF). However, it remained unclear whether rs889472 is associated with gout susceptibility. In the present study, we investigate the association between c-MAF rs889472 and gout in Japanese male population. We genotyped 625 male patients who were clinically diagnosed as gout and 1221 male control subjects without hyperuricemia or a history of gout by TaqMan method. As a result, the major allele (C), which reportedly increases SUA levels, had a higher frequency in the gout cases (58.8%) than in the controls (55.0%). A logistic regression analysis showed a significant association between rs889472 and gout (p = 0.029, odds ratio = 1.17; 95% confidence interval 1.02-1.34). C-MAF is reported as a pivotal transcriptional factor in the development and differentiation of renal proximal tubular cells. Because urate is mainly regulated in renal proximal tubular cells, c-MAF may have an important role in urate regulation in the kidney and influence not only SUA but also gout susceptibility. Our finding shows that rs889472 of c-MAF is associated with gout susceptibility.

  1. GSK3-mediated MAF phosphorylation in multiple myeloma as a potential therapeutic target

    International Nuclear Information System (INIS)

    Herath, N I; Rocques, N; Garancher, A; Eychène, A; Pouponnot, C

    2014-01-01

    Multiple myeloma (MM) is an incurable haematological malignancy characterised by the proliferation of mature antibody-secreting plasma B cells in the bone marrow. MM can arise from initiating translocations, of which the musculoaponeurotic fibrosarcoma (MAF) family is implicated in ∼5%. MMs bearing Maf translocations are of poor prognosis. These translocations are associated with elevated Maf expression, including c-MAF, MAFB and MAFA, and with t(14;16) and t(14;20) translocations, involving c-MAF and MAFB, respectively. c-MAF is also overexpressed in MM through MEK/ERK activation, bringing the number of MMs driven by the deregulation of a Maf gene close to 50%. Here we demonstrate that MAFB and c-MAF are phosphorylated by the Ser/Thr kinase GSK3 in human MM cell lines. We show that LiCl-induced GSK3 inhibition targets these phosphorylations and specifically decreases proliferation and colony formation of Maf-expressing MM cell lines. Interestingly, bortezomib induced stabilisation of Maf phosphorylation, an observation that could explain, at least partially, the low efficacy of bortezomib for patients carrying Maf translocations. Thus, GSK3 inhibition could represent a new therapeutic approach for these patients

  2. Prediction of optimal deployment projection for transcatheter aortic valve replacement: angiographic 3-dimensional reconstruction of the aortic root versus multidetector computed tomography.

    OpenAIRE

    Binder Ronald K; Leipsic Jonathon; Wood David; Moore Teri; Toggweiler Stefan; Willson Alex; Gurvitch Ronen; Freeman Melanie; Webb John G

    2012-01-01

    BACKGROUND Identifying the optimal fluoroscopic projection of the aortic valve is important for successful transcatheter aortic valve replacement (TAVR). Various imaging modalities including multidetector computed tomography (MDCT) have been proposed for prediction of the optimal deployment projection. We evaluated a method that provides 3 dimensional angiographic reconstructions (3DA) of the aortic root for prediction of the optimal deployment angle and compared it with MDCT. METHODS AND RES...

  3. Case Report: GcMAF Treatment in a Patient with Multiple Sclerosis.

    Science.gov (United States)

    Inui, Toshio; Katsuura, Goro; Kubo, Kentaro; Kuchiike, Daisuke; Chenery, Leslye; Uto, Yoshihiro; Nishikata, Takahito; Mette, Martin

    2016-07-01

    Gc protein-derived macrophage-activating factor (GcMAF) has various functions as an immune modulator, such as macrophage activation, anti-angiogenic activity and anti-tumor activity. Clinical trials of second-generation GcMAF demonstrated remarkable clinical effects in several types of cancers. Thus, GcMAF-based immunotherapy has a wide application for use in the treatment of many diseases via macrophage activation that can be used as a supportive therapy. Multiple sclerosis (MS) is considered to be an autoimmune disorder that affects the myelinated axons in the central nervous system (CNS). This study was undertaken to examine the effects of second-generation GcMAF in a patient with MS. This case study demonstrated that treatments of GcMAF in a patient with MS have potent therapeutic actions with early beneficial responses, especially improvement of motor dysfunction. GcMAF shows therapeutic potency in the treatment of MS. Copyright© 2016 International Institute of Anticancer Research (Dr. John G. Delinassios), All rights reserved.

  4. Inhibition of elastase-pulmonary emphysema in dominant-negative MafB transgenic mice.

    Science.gov (United States)

    Aida, Yasuko; Shibata, Yoko; Abe, Shuichi; Inoue, Sumito; Kimura, Tomomi; Igarashi, Akira; Yamauchi, Keiko; Nunomiya, Keiko; Kishi, Hiroyuki; Nemoto, Takako; Sato, Masamichi; Sato-Nishiwaki, Michiko; Nakano, Hiroshi; Sato, Kento; Kubota, Isao

    2014-01-01

    Alveolar macrophages (AMs) play important roles in the pathogenesis of chronic obstructive pulmonary disease (COPD). We previously demonstrated upregulation of the transcription factor MafB in AMs of mice exposed to cigarette smoke. The aim of this study was to elucidate the roles of MafB in the development of pulmonary emphysema. Porcine pancreatic elastase was administered to wild-type (WT) and dominant-negative (DN)-MafB transgenic (Tg) mice in which MafB activity was suppressed only in macrophages. We measured the mean linear intercept and conducted cell differential analysis of bronchoalveolar lavage (BAL) cells, surface marker analysis using flow cytometry, and immunohistochemical staining using antibodies to matrix metalloproteinase (MMP)-9 and MMP-12. Airspace enlargement of the lungs was suppressed significantly in elastase-treated DN-MafB Tg mice compared with treated WT mice. AMs with projected pseudopods were decreased in DN-MafB Tg mice. The number of cells intermediately positive for F4/80 and weakly or intermediately positive for CD11b, which are considered cell subsets of matured AMs, decreased in the BAL of DN-MafB Tg mice. Furthermore, MMP-9 and -12 were significantly downregulated in BAL cells of DN-MafB Tg mice. Because MMPs exacerbate emphysema, MafB may be involved in pulmonary emphysema development through altered maturation of macrophages and MMP expression.

  5. Immunotherapy for Prostate Cancer with Gc Protein-Derived Macrophage-Activating Factor, GcMAF.

    Science.gov (United States)

    Yamamoto, Nobuto; Suyama, Hirofumi; Yamamoto, Nobuyuki

    2008-07-01

    Serum Gc protein (known as vitamin D(3)-binding protein) is the precursor for the principal macrophage-activating factor (MAF). The MAF precursor activity of serum Gc protein of prostate cancer patients was lost or reduced because Gc protein was deglycosylated by serum alpha-N-acetylgalactosaminidase (Nagalase) secreted from cancerous cells. Therefore, macrophages of prostate cancer patients having deglycosylated Gc protein cannot be activated, leading to immunosuppression. Stepwise treatment of purified Gc protein with immobilized beta-galactosidase and sialidase generated the most potent MAF (termed GcMAF) ever discovered, which produces no adverse effect in humans. Macrophages activated by GcMAF develop a considerable variation of receptors that recognize the abnormality in malignant cell surface and are highly tumoricidal. Sixteen nonanemic prostate cancer patients received weekly administration of 100 ng of GcMAF. As the MAF precursor activity increased, their serum Nagalase activity decreased. Because serum Nagalase activity is proportional to tumor burden, the entire time course analysis for GcMAF therapy was monitored by measuring the serum Nagalase activity. After 14 to 25 weekly administrations of GcMAF (100 ng/week), all 16 patients had very low serum Nagalase levels equivalent to those of healthy control values, indicating that these patients are tumor-free. No recurrence occurred for 7 years.

  6. Loss of the RNA polymerase III repressor MAF1 confers obesity resistance.

    OpenAIRE

    Bonhoure, N.; Byrnes, A.; Moir, R.D.; Hodroj, W.; Preitner, F.; Praz, V.; Marcelin, G.; Chua, S.C.; Martinez-Lopez, N.; Singh, R.; Moullan, N.; Auwerx, J.; Willemin, G.; Shah, H.; Hartil, K.

    2015-01-01

    MAF1 is a global repressor of RNA polymerase III transcription that regulates the expression of highly abundant noncoding RNAs in response to nutrient availability and cellular stress. Thus, MAF1 function is thought to be important for metabolic economy. Here we show that a whole-body knockout of Maf1 in mice confers resistance to diet-induced obesity and nonalcoholic fatty liver disease by reducing food intake and increasing metabolic inefficiency. Energy expenditure in Maf1(-/-) mice is inc...

  7. Visualization of microvessels with in-house micro-angiography

    International Nuclear Information System (INIS)

    Chiku, Masaaki; Nishigami, Kazuhiro; Takeshita, Satoshi

    2005-01-01

    Although therapeutic angiogenesis improved critical limb ischemia in humans, microvessels promoted by therapeutic angiogenesis needed further improvement to be visualized well by conventional angiographic system, because of its limited spatial resolution of 200 μm. We have developed an in-house micro-angiographic system consisting of a high-voltage power X-ray source and a detecting system with high levels of spatial resolution and sensitivity. The in-house microvessel angiographic system demonstrated its ability to evaluate the function of microvessels in vivo, as well as to visualize them with higher precision than the conventional angiographic system. The findings of our study suggest that a novel micro-angiographic system may be useful in evaluating the efficacy of therapeutic angiogenesis in clinical settings. (author)

  8. Gc protein-derived macrophage activating factor (GcMAF): isoelectric focusing pattern and tumoricidal activity.

    Science.gov (United States)

    Mohamad, Saharuddin Bin; Nagasawa, Hideko; Sasaki, Hideyuki; Uto, Yoshihiro; Nakagawa, Yoshinori; Kawashima, Ken; Hori, Hitoshi

    2003-01-01

    Gc protein is the precursor for Gc protein-derived macrophage activating factor (GcMAF), with three phenotypes: Gc1f, Gc1s and Gc2, based on its electrophoretic mobility. The difference in electrophoretic mobility is because of the difference in its posttranslational sugar moiety composition. We compared the difference between Gc protein and GcMAF electrophoretic mobility using the isoelectric focusing (IEF) method. The tumoricidal activity of GcMAF-treated macrophage was evaluated after coculture with L-929 cell. The tumoricidal mechanism was investigated using TNF bioassay and nitric oxide (NO) release. The difference in Gc protein and GcMAF electrophoretic mobility was detected. The tumoricidal activity of GcMAF-treated macrophage was detected, but no release of TNF and NO was detected. The difference of isoelectric focusing mobility in Gc protein and GcMAF would be useful to develop a GcMAF detection method. GcMAF increased macrophage tumoricidal activity but TNF and NO release were not involved in the mechanism.

  9. Immunotherapy for Prostate Cancer with Gc Protein-Derived Macrophage-Activating Factor, GcMAF1

    Science.gov (United States)

    Yamamoto, Nobuto; Suyama, Hirofumi; Yamamoto, Nobuyuki

    2008-01-01

    Serum Gc protein (known as vitamin D3-binding protein) is the precursor for the principal macrophage-activating factor (MAF). The MAF precursor activity of serum Gc protein of prostate cancer patients was lost or reduced because Gc protein was deglycosylated by serum α-N-acetylgalactosaminidase (Nagalase) secreted from cancerous cells. Therefore, macrophages of prostate cancer patients having deglycosylated Gc protein cannot be activated, leading to immunosuppression. Stepwise treatment of purified Gc protein with immobilized β-galactosidase and sialidase generated the most potent MAF (termed GcMAF) ever discovered, which produces no adverse effect in humans. Macrophages activated by GcMAF develop a considerable variation of receptors that recognize the abnormality in malignant cell surface and are highly tumoricidal. Sixteen nonanemic prostate cancer patients received weekly administration of 100 ng of GcMAF. As the MAF precursor activity increased, their serum Nagalase activity decreased. Because serum Nagalase activity is proportional to tumor burden, the entire time course analysis for GcMAF therapy was monitored by measuring the serum Nagalase activity. After 14 to 25 weekly administrations of GcMAF (100 ng/week), all 16 patients had very low serum Nagalase levels equivalent to those of healthy control values, indicating that these patients are tumor-free. No recurrence occurred for 7 years. PMID:18633461

  10. Functionality and operation of fluoroscopic automatic brightness control/automatic dose rate control logic in modern cardiovascular and interventional angiography systems: a report of Task Group 125 Radiography/Fluoroscopy Subcommittee, Imaging Physics Committee, Science Council.

    Science.gov (United States)

    Rauch, Phillip; Lin, Pei-Jan Paul; Balter, Stephen; Fukuda, Atsushi; Goode, Allen; Hartwell, Gary; LaFrance, Terry; Nickoloff, Edward; Shepard, Jeff; Strauss, Keith

    2012-05-01

    Task Group 125 (TG 125) was charged with investigating the functionality of fluoroscopic automatic dose rate and image quality control logic in modern angiographic systems, paying specific attention to the spectral shaping filters and variations in the selected radiologic imaging parameters. The task group was also charged with describing the operational aspects of the imaging equipment for the purpose of assisting the clinical medical physicist with clinical set-up and performance evaluation. Although there are clear distinctions between the fluoroscopic operation of an angiographic system and its acquisition modes (digital cine, digital angiography, digital subtraction angiography, etc.), the scope of this work was limited to the fluoroscopic operation of the systems studied. The use of spectral shaping filters in cardiovascular and interventional angiography equipment has been shown to reduce patient dose. If the imaging control algorithm were programmed to work in conjunction with the selected spectral filter, and if the generator parameters were optimized for the selected filter, then image quality could also be improved. Although assessment of image quality was not included as part of this report, it was recognized that for fluoroscopic imaging the parameters that influence radiation output, differential absorption, and patient dose are also the same parameters that influence image quality. Therefore, this report will utilize the terminology "automatic dose rate and image quality" (ADRIQ) when describing the control logic in modern interventional angiographic systems and, where relevant, will describe the influence of controlled parameters on the subsequent image quality. A total of 22 angiography units were investigated by the task group and of these one each was chosen as representative of the equipment manufactured by GE Healthcare, Philips Medical Systems, Shimadzu Medical USA, and Siemens Medical Systems. All equipment, for which measurement data were

  11. Functionality and operation of fluoroscopic automatic brightness control/automatic dose rate control logic in modern cardiovascular and interventional angiography systems: A Report of Task Group 125 Radiography/Fluoroscopy Subcommittee, Imaging Physics Committee, Science Council

    Energy Technology Data Exchange (ETDEWEB)

    Rauch, Phillip; Lin, Pei-Jan Paul; Balter, Stephen; Fukuda, Atsushi; Goode, Allen; Hartwell, Gary; LaFrance, Terry; Nickoloff, Edward; Shepard, Jeff; Strauss, Keith [Henry Ford Health System, Detroit, Michigan 48202 (United States); Beth Israel Deaconess Medical Center, Boston, Massachusetts 02115 (United States); Columbia University Medical Center, New York, New York 10032 (United States); Shiga Medical Center for Children, Moriyama City, Shiga-Ken, Japan 524-0022 (Japan); University of Virginia Health Science Center, Charlottesville, Virginia 22908 (United States); Baystate Health Systems, Inc., Springfield, Massachusetts 01199 (United States); Columbia University Medical Center, New York, New York 10032 (United States); University of Texas M.D. Anderson Cancer Center, Houston, Texas 77030 (United States); Cincinnati Children' s Hospital Medical Center, Cincinnati, Ohio 45229 (United States)

    2012-05-15

    Task Group 125 (TG 125) was charged with investigating the functionality of fluoroscopic automatic dose rate and image quality control logic in modern angiographic systems, paying specific attention to the spectral shaping filters and variations in the selected radiologic imaging parameters. The task group was also charged with describing the operational aspects of the imaging equipment for the purpose of assisting the clinical medical physicist with clinical set-up and performance evaluation. Although there are clear distinctions between the fluoroscopic operation of an angiographic system and its acquisition modes (digital cine, digital angiography, digital subtraction angiography, etc.), the scope of this work was limited to the fluoroscopic operation of the systems studied. The use of spectral shaping filters in cardiovascular and interventional angiography equipment has been shown to reduce patient dose. If the imaging control algorithm were programmed to work in conjunction with the selected spectral filter, and if the generator parameters were optimized for the selected filter, then image quality could also be improved. Although assessment of image quality was not included as part of this report, it was recognized that for fluoroscopic imaging the parameters that influence radiation output, differential absorption, and patient dose are also the same parameters that influence image quality. Therefore, this report will utilize the terminology ''automatic dose rate and image quality'' (ADRIQ) when describing the control logic in modern interventional angiographic systems and, where relevant, will describe the influence of controlled parameters on the subsequent image quality. A total of 22 angiography units were investigated by the task group and of these one each was chosen as representative of the equipment manufactured by GE Healthcare, Philips Medical Systems, Shimadzu Medical USA, and Siemens Medical Systems. All equipment, for which

  12. Functionality and operation of fluoroscopic automatic brightness control/automatic dose rate control logic in modern cardiovascular and interventional angiography systems: A Report of Task Group 125 Radiography/Fluoroscopy Subcommittee, Imaging Physics Committee, Science Council

    International Nuclear Information System (INIS)

    Rauch, Phillip; Lin, Pei-Jan Paul; Balter, Stephen; Fukuda, Atsushi; Goode, Allen; Hartwell, Gary; LaFrance, Terry; Nickoloff, Edward; Shepard, Jeff; Strauss, Keith

    2012-01-01

    Task Group 125 (TG 125) was charged with investigating the functionality of fluoroscopic automatic dose rate and image quality control logic in modern angiographic systems, paying specific attention to the spectral shaping filters and variations in the selected radiologic imaging parameters. The task group was also charged with describing the operational aspects of the imaging equipment for the purpose of assisting the clinical medical physicist with clinical set-up and performance evaluation. Although there are clear distinctions between the fluoroscopic operation of an angiographic system and its acquisition modes (digital cine, digital angiography, digital subtraction angiography, etc.), the scope of this work was limited to the fluoroscopic operation of the systems studied. The use of spectral shaping filters in cardiovascular and interventional angiography equipment has been shown to reduce patient dose. If the imaging control algorithm were programmed to work in conjunction with the selected spectral filter, and if the generator parameters were optimized for the selected filter, then image quality could also be improved. Although assessment of image quality was not included as part of this report, it was recognized that for fluoroscopic imaging the parameters that influence radiation output, differential absorption, and patient dose are also the same parameters that influence image quality. Therefore, this report will utilize the terminology ''automatic dose rate and image quality'' (ADRIQ) when describing the control logic in modern interventional angiographic systems and, where relevant, will describe the influence of controlled parameters on the subsequent image quality. A total of 22 angiography units were investigated by the task group and of these one each was chosen as representative of the equipment manufactured by GE Healthcare, Philips Medical Systems, Shimadzu Medical USA, and Siemens Medical Systems. All equipment, for which measurement data were

  13. Loss of the RNA polymerase III repressor MAF1 confers obesity resistance.

    Science.gov (United States)

    Bonhoure, Nicolas; Byrnes, Ashlee; Moir, Robyn D; Hodroj, Wassim; Preitner, Frédéric; Praz, Viviane; Marcelin, Genevieve; Chua, Streamson C; Martinez-Lopez, Nuria; Singh, Rajat; Moullan, Norman; Auwerx, Johan; Willemin, Gilles; Shah, Hardik; Hartil, Kirsten; Vaitheesvaran, Bhavapriya; Kurland, Irwin; Hernandez, Nouria; Willis, Ian M

    2015-05-01

    MAF1 is a global repressor of RNA polymerase III transcription that regulates the expression of highly abundant noncoding RNAs in response to nutrient availability and cellular stress. Thus, MAF1 function is thought to be important for metabolic economy. Here we show that a whole-body knockout of Maf1 in mice confers resistance to diet-induced obesity and nonalcoholic fatty liver disease by reducing food intake and increasing metabolic inefficiency. Energy expenditure in Maf1(-/-) mice is increased by several mechanisms. Precursor tRNA synthesis was increased in multiple tissues without significant effects on mature tRNA levels, implying increased turnover in a futile tRNA cycle. Elevated futile cycling of hepatic lipids was also observed. Metabolite profiling of the liver and skeletal muscle revealed elevated levels of many amino acids and spermidine, which links the induction of autophagy in Maf1(-/-) mice with their extended life span. The increase in spermidine was accompanied by reduced levels of nicotinamide N-methyltransferase, which promotes polyamine synthesis, enables nicotinamide salvage to regenerate NAD(+), and is associated with obesity resistance. Consistent with this, NAD(+) levels were increased in muscle. The importance of MAF1 for metabolic economy reveals the potential for MAF1 modulators to protect against obesity and its harmful consequences. © 2015 Bonhoure et al.; Published by Cold Spring Harbor Laboratory Press.

  14. Effects of vitamin D(3)-binding protein-derived macrophage activating factor (GcMAF) on angiogenesis.

    Science.gov (United States)

    Kanda, Shigeru; Mochizuki, Yasushi; Miyata, Yasuyoshi; Kanetake, Hiroshi; Yamamoto, Nobuto

    2002-09-04

    The vitamin D(3)-binding protein (Gc protein)-derived macrophage activating factor (GcMAF) activates tumoricidal macrophages against a variety of cancers indiscriminately. We investigated whether GcMAF also acts as an antiangiogenic factor on endothelial cells. The effects of GcMAF on angiogenic growth factor-induced cell proliferation, chemotaxis, and tube formation were examined in vitro by using cultured endothelial cells (murine IBE cells, porcine PAE cells, and human umbilical vein endothelial cells [HUVECs]) and in vivo by using a mouse cornea micropocket assay. Blocking monoclonal antibodies to CD36, a receptor for the antiangiogenic factor thrombospondin-1, which is also a possible receptor for GcMAF, were used to investigate the mechanism of GcMAF action. GcMAF inhibited the endothelial cell proliferation, chemotaxis, and tube formation that were all stimulated by fibroblast growth factor-2 (FGF-2), vascular endothelial growth factor-A, or angiopoietin 2. FGF-2-induced neovascularization in murine cornea was also inhibited by GcMAF. Monoclonal antibodies against murine and human CD36 receptor blocked the antiangiogenic action of GcMAF on the angiogenic factor stimulation of endothelial cell chemotaxis. In addition to its ability to activate tumoricidal macrophages, GcMAF has direct antiangiogenic effects on endothelial cells independent of tissue origin. The antiangiogenic effects of GcMAF may be mediated through the CD36 receptor.

  15. The transcription factor c-Maf controls touch receptor development and function.

    Science.gov (United States)

    Wende, Hagen; Lechner, Stefan G; Cheret, Cyril; Bourane, Steeve; Kolanczyk, Maria E; Pattyn, Alexandre; Reuter, Katja; Munier, Francis L; Carroll, Patrick; Lewin, Gary R; Birchmeier, Carmen

    2012-03-16

    The sense of touch relies on detection of mechanical stimuli by specialized mechanosensory neurons. The scarcity of molecular data has made it difficult to analyze development of mechanoreceptors and to define the basis of their diversity and function. We show that the transcription factor c-Maf/c-MAF is crucial for mechanosensory function in mice and humans. The development and function of several rapidly adapting mechanoreceptor types are disrupted in c-Maf mutant mice. In particular, Pacinian corpuscles, a type of mechanoreceptor specialized to detect high-frequency vibrations, are severely atrophied. In line with this, sensitivity to high-frequency vibration is reduced in humans carrying a dominant mutation in the c-MAF gene. Thus, our work identifies a key transcription factor specifying development and function of mechanoreceptors and their end organs.

  16. Global regulation of gene expression by the MafR protein of Enterococcus faecalis

    Directory of Open Access Journals (Sweden)

    Sofía eRuiz-Cruz

    2016-01-01

    Full Text Available Enterococcus faecalis is a natural inhabitant of the human gastrointestinal tract. However, as an opportunistic pathogen, it is able to colonize other host niches and cause life-threatening infections. Its adaptation to new environments involves global changes in gene expression. The EF3013 gene (here named mafR of E. faecalis strain V583 encodes a protein (MafR, 482 residues that has sequence similarity to global response regulators of the Mga/AtxA family. The enterococcal OG1RF genome also encodes the MafR protein (gene OG1RF_12293. In this work, we have identified the promoter of the mafR gene using several in vivo approaches. Moreover, we show that MafR influences positively the transcription of many genes on a genome-wide scale. The most significant target genes encode components of PTS-type membrane transporters, components of ABC-type membrane transporters, and proteins involved in the metabolism of carbon sources. Some of these genes were previously reported to be up-regulated during the growth of E. faecalis in blood and/or in human urine. Furthermore, we show that a mafR deletion mutant strain induces a significant lower degree of inflammation in the peritoneal cavity of mice, suggesting that enterococcal cells deficient in MafR are less virulent. Our work indicates that MafR is a global transcriptional regulator. It might facilitate the adaptation of E. faecalis to particular host niches and, therefore, contribute to its potential virulence.

  17. Isolation and Functional Characterization of a Floral Repressor, BcMAF1, From Pak-choi (Brassica rapa ssp. Chinensis).

    Science.gov (United States)

    Huang, Feiyi; Liu, Tongkun; Hou, Xilin

    2018-01-01

    MADS-box genes form a large gene family in plants and are involved in multiple biological processes, such as flowering. However, the regulation mechanism of MADS-box genes in flowering remains unresolved, especially under short-term cold conditions. In the present study, we isolated BcMAF1 , a Pak-choi ( Brassica rapa ssp. Chinensis ) MADS AFFECTING FLOWERING ( MAF ), as a floral repressor and functionally characterized BcMAF1 in Arabidopsis and Pak-choi. Subcellular localization and sequence analysis indicated that BcMAF1 was a nuclear protein and contained a conserved MADS-box domain. Expression analysis revealed that BcMAF1 had higher expression levels in leaves, stems, and petals, and could be induced by short-term cold conditions in Pak-choi. Overexpressing BcMAF1 in Arabidopsis showed that BcMAF1 had a negative function in regulating flowering, which was further confirmed by silencing endogenous BcMAF1 in Pak-choi. In addition, qPCR results showed that AtAP3 expression was reduced and AtMAF2 expression was induced in BcMAF1 -overexpressing Arabidopsis . Meanwhile, BcAP3 transcript was up-regulated and BcMAF2 transcript was down-regulated in BcMAF1 -silencing Pak-choi. Yeast one-hybrid and dual luciferase transient assays showed that BcMAF1 could bind to the promoters of BcAP3 and BcMAF2 . These results indicated that BcAP3 and BcMAF2 might be the targets of BcMAF1. Taken together, our results suggested that BcMAF1 could negatively regulate flowering by directly activating BcMAF2 and repressing BcAP3 .

  18. Crystal Structure and Regulation of the Citrus Pol III Repressor MAF1 by Auxin and Phosphorylation.

    Science.gov (United States)

    Soprano, Adriana Santos; Giuseppe, Priscila Oliveira de; Shimo, Hugo Massayoshi; Lima, Tatiani Brenelli; Batista, Fernanda Aparecida Heleno; Righetto, Germanna Lima; Pereira, José Geraldo de Carvalho; Granato, Daniela Campos; Nascimento, Andrey Fabricio Ziem; Gozzo, Fabio Cesar; de Oliveira, Paulo Sérgio Lopes; Figueira, Ana Carolina Migliorini; Smetana, Juliana Helena Costa; Paes Leme, Adriana Franco; Murakami, Mario Tyago; Benedetti, Celso Eduardo

    2017-09-05

    MAF1 is the main RNA polymerase (Pol) III repressor that controls cell growth in eukaryotes. The Citrus ortholog, CsMAF1, was shown to restrict cell growth in citrus canker disease but its role in plant development and disease is still unclear. We solved the crystal structure of the globular core of CsMAF1, which reveals additional structural elements compared with the previously available structure of hMAF1, and explored the dynamics of its flexible regions not present in the structure. CsMAF1 accumulated in the nucleolus upon leaf excision, and this translocation was inhibited by auxin and by mutation of the PKA phosphorylation site, S45, to aspartate. Additionally, mTOR phosphorylated recombinant CsMAF1 and the mTOR inhibitor AZD8055 blocked canker formation in normal but not CsMAF1-silenced plants. These results indicate that the role of TOR on cell growth induced by Xanthomonas citri depends on CsMAF1 and that auxin controls CsMAF1 interaction with Pol III in citrus. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. MafB is required for development of the hindbrain choroid plexus

    International Nuclear Information System (INIS)

    Koshida, Ryusuke; Oishi, Hisashi; Hamada, Michito; Takei, Yosuke; Takahashi, Satoru

    2017-01-01

    The choroid plexus (ChP) is a non-neural epithelial tissue that produces cerebrospinal fluid (CSF). The ChP differentiates from the roof plate, a dorsal midline structure of the neural tube. However, molecular mechanisms underlying ChP development are poorly understood compared to neural development. MafB is a bZip transcription factor that is known to be expressed in the roof plate. Here we investigated the role of MafB in embryonic development of the hindbrain ChP (hChP) using Mafb-deficient mice. Immunohistochemical analyses revealed that MafB is expressed in the roof plate and early hChP epithelial cells but its expression disappears at a later embryonic stage. We also found that the Mafb-deficient hChP exhibits delayed differentiation and results in hypoplasia compared to the wild-type hChP. Furthermore, the Mafb-deficient hChP exhibits increased apoptotic cell death and decreased proliferating cells at E12.5, an early stage of hChP development. Collectively, our findings reveal that MafB play an important role in promoting hChP development during embryogenesis. - Highlights: • MafB is expressed in the roof plate and the early hindbrain choroid plexus (hChP). • Loss of MafB causes delayed differentiation and hypoplasia of the embryonic hChP. • The Mafb-deficient hChP exhibits increased apoptosis and decreased proliferation.

  20. Preparation of Gc protein-derived macrophage activating factor (GcMAF) and its structural characterization and biological activities.

    Science.gov (United States)

    Mohamad, Saharuddin Bin; Nagasawa, Hideko; Uto, Yoshihiro; Hori, Hitoshi

    2002-01-01

    Gc protein has been reported to be a precursor of Gc protein-derived macrophage activation factor (GcMAF) in the inflammation-primed macrophage activation cascade. An inducible beta-galactosidase of B cells and neuraminidase of T cells convert Gc protein to GcMAF. Gc protein from human serum was purified using 25(OH)D3 affinity column chromatography and modified to GcMAF using immobilized glycosidases (beta-galactosidase and neuraminidase) The sugar moiety structure of GcMAF was characterized by lectin blotting by Helix pomatia agglutinin. The biological activities of GcMAF were evaluated by a superoxide generation assay and a phagocytosis assay. We successfully purified Gc protein from human serum. GcMAF was detected by lectin blotting and showed a high biological activity. Our results support the importance of the terminal N-acetylgalactosamine moiety in the GcMAF-mediated macrophage activation cascade, and the existence of constitutive GcMAF in human serum. These preliminary data are important for designing small molecular GcMAF mimics.

  1. The transcription factor Lc-Maf participates in Col27a1 regulation during chondrocyte maturation

    Energy Technology Data Exchange (ETDEWEB)

    Mayo, Jaime L.; Holden, Devin N. [Department of Microbiology and Molecular Biology, Brigham Young University, 591 WIDB, Provo, UT 84602 (United States); Barrow, Jeffery R. [Department of Physiology and Developmental Biology, Brigham Young University, Provo, UT 84602 (United States); Bridgewater, Laura C., E-mail: laura_bridgewater@byu.edu [Department of Microbiology and Molecular Biology, Brigham Young University, 591 WIDB, Provo, UT 84602 (United States)

    2009-08-01

    The transcription factor Lc-Maf, which is a splice variant of c-Maf, is expressed in cartilage undergoing endochondral ossification and participates in the regulation of type II collagen through a cartilage-specific Col2a1 enhancer element. Type XXVII and type XI collagens are also expressed in cartilage during endochondral ossification, and so enhancer/reporter assays were used to determine whether Lc-Maf could regulate cartilage-specific enhancers from the Col27a1 and Col11a2 genes. The Col27a1 enhancer was upregulated over 4-fold by Lc-Maf, while the Col11a2 enhancer was downregulated slightly. To confirm the results of these reporter assays, rat chondrosarcoma (RCS) cells were transiently transfected with an Lc-Maf expression plasmid, and quantitative RT-PCR was performed to measure the expression of endogenous Col27a1 and Col11a2 genes. Endogenous Col27a1 was upregulated 6-fold by Lc-Maf overexpression, while endogenous Col11a2 was unchanged. Finally, in situ hybridization and immunohistochemistry were performed in the radius and ulna of embryonic day 17 mouse forelimbs undergoing endochondral ossification. Results demonstrated that Lc-Maf and Col27a1 mRNAs are coexpressed in proliferating and prehypertrophic regions, as would be predicted if Lc-Maf regulates Col27a1 expression. Type XXVII collagen protein was also most abundant in prehypertrophic and proliferating chondrocytes. Others have shown that mice that are null for Lc-Maf and c-Maf have expanded hypertrophic regions with reduced ossification and delayed vascularization. Separate studies have indicated that Col27a1 may serve as a scaffold for ossification and vascularization. The work presented here suggests that Lc-Maf may affect the process of endochondral ossification by participating in the regulation of Col27a1 expression.

  2. mTORC1 directly phosphorylates and regulates human MAF1.

    Science.gov (United States)

    Michels, Annemieke A; Robitaille, Aaron M; Buczynski-Ruchonnet, Diane; Hodroj, Wassim; Reina, Jaime H; Hall, Michael N; Hernandez, Nouria

    2010-08-01

    mTORC1 is a central regulator of growth in response to nutrient availability, but few direct targets have been identified. RNA polymerase (pol) III produces a number of essential RNA molecules involved in protein synthesis, RNA maturation, and other processes. Its activity is highly regulated, and deregulation can lead to cell transformation. The human phosphoprotein MAF1 becomes dephosphorylated and represses pol III transcription after various stresses, but neither the significance of the phosphorylations nor the kinase involved is known. We find that human MAF1 is absolutely required for pol III repression in response to serum starvation or TORC1 inhibition by rapamycin or Torin1. The protein is phosphorylated mainly on residues S60, S68, and S75, and this inhibits its pol III repression function. The responsible kinase is mTORC1, which phosphorylates MAF1 directly. Our results describe molecular mechanisms by which mTORC1 controls human MAF1, a key repressor of RNA polymerase III transcription, and add a new branch to the signal transduction cascade immediately downstream of TORC1.

  3. Degalactosylated/desialylated human serum containing GcMAF induces macrophage phagocytic activity and in vivo antitumor activity.

    Science.gov (United States)

    Kuchiike, Daisuke; Uto, Yoshihiro; Mukai, Hirotaka; Ishiyama, Noriko; Abe, Chiaki; Tanaka, Daichi; Kawai, Tomohito; Kubo, Kentaro; Mette, Martin; Inui, Toshio; Endo, Yoshio; Hori, Hitoshi

    2013-07-01

    The group-specific component protein-derived macrophage-activating factor (GcMAF) has various biological activities, such as macrophage activation and antitumor activity. Clinical trials of GcMAF have been carried out for metastatic breast cancer, prostate cancer, and metastatic colorectal cancer. In this study, despite the complicated purification process of GcMAF, we used enzymatically-treated human serum containing GcMAF with a considerable macrophage-stimulating activity and antitumor activity. We detected GcMAF in degalactosylated/desialylated human serum by western blotting using an anti-human Gc globulin antibody, and Helix pomatia agglutinin lectin. We also found that GcMAF-containing human serum significantly enhanced the phagocytic activity of mouse peritoneal macrophages and extended the survival time of mice bearing Ehrlich ascites tumors. We demonstrated that GcMAF-containing human serum can be used as a potential macrophage activator for cancer immunotherapy.

  4. Fluoroscopic digital radiography

    International Nuclear Information System (INIS)

    Hynes, D.M.; Rowlands, J.A.; Edmonds, E.W.; Porter, A.J.; Toth, B.D.

    1987-01-01

    The authors have been working with three different developmental systems, exploring the clinical benefits of digital recording of the fluoroscopic image. This educational exhibit describes the components of such systems and emphasizes the strengths and weaknesses of each. Specific technical reference is made to the image intensifier, TV camera, 1,024/sup 2/ image store, hard copy devices, and the mechanics of operation in the general fluoroscopic environment. All observations indicate that the problems of resolution, motion blur, noise, field size, and dose can be solved. The findings are supported by clinical examples

  5. The Transcription Factor c-Maf Promotes the Differentiation of Follicular Helper T Cells

    Directory of Open Access Journals (Sweden)

    Fabienne Andris

    2017-04-01

    Full Text Available Follicular helper T cells (Tfh have been identified as the primary cell subpopulation regulating B cell responses in germinal centers, thus supporting high-affinity antibody production. Among the transcription factors orchestrating Tfh cell differentiation and function, the role played by the proto-oncogene c-Maf remains poorly characterized. We report herein that selective loss of c-Maf expression in the T cell compartment results in defective development of Tfh cells in response to both antigen/adjuvant vaccinations and commensal intestinal bacteria. Accordingly, c-Maf expression in T cells was essential for the development and high-affinity antibody secretion in vaccinated animals. c-Maf was expressed early, concomitantly to BCL6, in Tfh cell precursors and found to regulate Tfh fate in a cell-autonomous fashion. Altogether, our findings reveal a novel, non-redundant, function for c-Maf in the differentiation of Tfh cells and the regulation of humoral immune responses to T-cell-dependent antigens.

  6. Immunotherapy of metastatic colorectal cancer with vitamin D-binding protein-derived macrophage-activating factor, GcMAF.

    Science.gov (United States)

    Yamamoto, Nobuto; Suyama, Hirofumi; Nakazato, Hiroaki; Yamamoto, Nobuyuki; Koga, Yoshihiko

    2008-07-01

    Serum vitamin D binding protein (Gc protein) is the precursor for the principal macrophage-activating factor (MAF). The MAF precursor activity of serum Gc protein of colorectal cancer patients was lost or reduced because Gc protein is deglycosylated by serum alpha-N-acetylgalactosaminidase (Nagalase) secreted from cancerous cells. Deglycosylated Gc protein cannot be converted to MAF, leading to immunosuppression. Stepwise treatment of purified Gc protein with immobilized beta-galactosidase and sialidase generated the most potent macrophage-activating factor (GcMAF) ever discovered, but it produces no side effect in humans. Macrophages treated with GcMAF (100 microg/ml) develop an enormous variation of receptors and are highly tumoricidal to a variety of cancers indiscriminately. Administration of 100 nanogram (ng)/ human maximally activates systemic macrophages that can kill cancerous cells. Since the half-life of the activated macrophages is approximately 6 days, 100 ng GcMAF was administered weekly to eight nonanemic colorectal cancer patients who had previously received tumor-resection but still carried significant amounts of metastatic tumor cells. As GcMAF therapy progressed, the MAF precursor activities of all patients increased and conversely their serum Nagalase activities decreased. Since serum Nagalase is proportional to tumor burden, serum Nagalase activity was used as a prognostic index for time course analysis of GcMAF therapy. After 32-50 weekly administrations of 100 ng GcMAF, all colorectal cancer patients exhibited healthy control levels of the serum Nagalase activity, indicating eradication of metastatic tumor cells. During 7 years after the completion of GcMAF therapy, their serum Nagalase activity did not increase, indicating no recurrence of cancer, which was also supported by the annual CT scans of these patients.

  7. Fluoroscopically-guided foam sclerotherapy with sodium morrhuate for the treatment of lower extremity varices

    International Nuclear Information System (INIS)

    Wang Haiting; Jiang Zhongpu; Zhou Yi

    2011-01-01

    Objective: To evaluate fluoroscopically-guided foam sclerotherapy with injection of domestic sodium morrhuate in treating lower extremity varices. Methods: A total of 30 cases (39 diseased lower limbs) with lower extremity varices were enrolled in this study. Under fluoroscopic guidance foam sclerotherapy with injection of domestic sodium morrhuate was carried out in all patients. The obstructed condition of the great saphenous vein was observed during the following three months. Results: The technical success was achieved in all 39 patients. The mean dose of foam sclerosant used for each diseased limb was 5.9 ml (3.4-8.2 ml). Disappearance of blood flow reflux in lower extremity vein immediately after the treatment was seen in 35 patients (90%). Three months after the therapy, vascular sonography showed that the great saphenous vein was obstructed, and no serious complications occurred. Conclusion: For the treatment of lower extremity varices, fluoroscopically-guided foam sclerotherapy with injection of domestic sodium morrhuate is safe and effective with satisfactory results. This technique is a newly-developed micro-invasive therapy for lower extremity varices. (authors)

  8. Integration and diversity of the regulatory network composed of Maf and CNC families of transcription factors.

    Science.gov (United States)

    Motohashi, Hozumi; O'Connor, Tania; Katsuoka, Fumiki; Engel, James Douglas; Yamamoto, Masayuki

    2002-07-10

    Recent progress in the analysis of transcriptional regulation has revealed the presence of an exquisite functional network comprising the Maf and Cap 'n' collar (CNC) families of regulatory proteins, many of which have been isolated. Among Maf factors, large Maf proteins are important in the regulation of embryonic development and cell differentiation, whereas small Maf proteins serve as obligatory heterodimeric partner molecules for members of the CNC family. Both Maf homodimers and CNC-small Maf heterodimers bind to the Maf recognition element (MARE). Since the MARE contains a consensus TRE sequence recognized by AP-1, Jun and Fos family members may act to compete or interfere with the function of CNC-small Maf heterodimers. Overall then, the quantitative balance of transcription factors interacting with the MARE determines its transcriptional activity. Many putative MARE-dependent target genes such as those induced by antioxidants and oxidative stress are under concerted regulation by the CNC family member Nrf2, as clearly proven by mouse germline mutagenesis. Since these genes represent a vital aspect of the cellular defense mechanism against oxidative stress, Nrf2-null mutant mice are highly sensitive to xenobiotic and oxidative insults. Deciphering the molecular basis of the regulatory network composed of Maf and CNC families of transcription factors will undoubtedly lead to a new paradigm for the cooperative function of transcription factors.

  9. MafB antagonizes phenotypic alteration induced by GM-CSF in microglia

    Energy Technology Data Exchange (ETDEWEB)

    Koshida, Ryusuke, E-mail: rkoshida-myz@umin.ac.jp; Oishi, Hisashi, E-mail: hoishi@md.tsukuba.ac.jp; Hamada, Michito; Takahashi, Satoru

    2015-07-17

    Microglia are tissue-resident macrophages which are distributed throughout the central nervous system (CNS). Recent studies suggest that microglia are a unique myeloid population distinct from peripheral macrophages in terms of origin and gene expression signature. Granulocyte-macrophage colony-stimulating factor (GM-CSF), a pleiotropic cytokine regulating myeloid development, has been shown to stimulate proliferation and alter phenotype of microglia in vitro. However, how its signaling is modulated in microglia is poorly characterized. MafB, a bZip transcriptional factor, is highly expressed in monocyte-macrophage lineage cells including microglia, although its role in microglia is largely unknown. We investigated the crosstalk between GM-CSF signaling and MafB by analyzing primary microglia. We found that Mafb-deficient microglia grew more rapidly than wild-type microglia in response to GM-CSF. Moreover, the expression of genes associated with microglial differentiation was more downregulated in Mafb-deficient microglia cultured with GM-CSF. Notably, such differences between the genotypes were not observed in the presence of M-CSF. In addition, we found that Mafb-deficient microglia cultured with GM-CSF barely extended their membrane protrusions, probably due to abnormal activation of RhoA, a key regulator of cytoskeletal remodeling. Altogether, our study reveals that MafB is a negative regulator of GM-CSF signaling in microglia. These findings could provide new insight into the modulation of cytokine signaling by transcription factors in microglia. - Highlights: • GM-CSF alters the phenotype of microglia in vitro more potently than M-CSF. • Transcription factor MafB antagonizes the effect of GM-CSF on microglia in vitro. • MafB deficiency leads to RhoA activation in microglia in response to GM-CSF. • We show for the first time the function of MafB in microglia.

  10. mTORC1 Directly Phosphorylates and Regulates Human MAF1▿

    Science.gov (United States)

    Michels, Annemieke A.; Robitaille, Aaron M.; Buczynski-Ruchonnet, Diane; Hodroj, Wassim; Reina, Jaime H.; Hall, Michael N.; Hernandez, Nouria

    2010-01-01

    mTORC1 is a central regulator of growth in response to nutrient availability, but few direct targets have been identified. RNA polymerase (pol) III produces a number of essential RNA molecules involved in protein synthesis, RNA maturation, and other processes. Its activity is highly regulated, and deregulation can lead to cell transformation. The human phosphoprotein MAF1 becomes dephosphorylated and represses pol III transcription after various stresses, but neither the significance of the phosphorylations nor the kinase involved is known. We find that human MAF1 is absolutely required for pol III repression in response to serum starvation or TORC1 inhibition by rapamycin or Torin1. The protein is phosphorylated mainly on residues S60, S68, and S75, and this inhibits its pol III repression function. The responsible kinase is mTORC1, which phosphorylates MAF1 directly. Our results describe molecular mechanisms by which mTORC1 controls human MAF1, a key repressor of RNA polymerase III transcription, and add a new branch to the signal transduction cascade immediately downstream of TORC1. PMID:20516213

  11. Immunotherapy of metastatic breast cancer patients with vitamin D-binding protein-derived macrophage activating factor (GcMAF).

    Science.gov (United States)

    Yamamoto, Nobuto; Suyama, Hirofumi; Yamamoto, Nobuyuki; Ushijima, Naofumi

    2008-01-15

    Serum vitamin D3-binding protein (Gc protein) is the precursor for the principal macrophage activating factor (MAF). The MAF precursor activity of serum Gc protein of breast cancer patients was lost or reduced because Gc protein was deglycosylated by serum alpha-N-acetylgalactosaminidase (Nagalase) secreted from cancerous cells. Patient serum Nagalase activity is proportional to tumor burden. The deglycosylated Gc protein cannot be converted to MAF, resulting in no macrophage activation and immunosuppression. Stepwise incubation of purified Gc protein with immobilized beta-galactosidase and sialidase generated probably the most potent macrophage activating factor (termed GcMAF) ever discovered, which produces no adverse effect in humans. Macrophages treated in vitro with GcMAF (100 pg/ml) are highly tumoricidal to mammary adenocarcinomas. Efficacy of GcMAF for treatment of metastatic breast cancer was investigated with 16 nonanemic patients who received weekly administration of GcMAF (100 ng). As GcMAF therapy progresses, the MAF precursor activity of patient Gc protein increased with a concomitant decrease in serum Nagalase. Because of proportionality of serum Nagalase activity to tumor burden, the time course progress of GcMAF therapy was assessed by serum Nagalase activity as a prognostic index. These patients had the initial Nagalase activities ranging from 2.32 to 6.28 nmole/min/mg protein. After about 16-22 administrations (approximately 3.5-5 months) of GcMAF, these patients had insignificantly low serum enzyme levels equivalent to healthy control enzyme levels, ranging from 0.38 to 0.63 nmole/min/mg protein, indicating eradication of the tumors. This therapeutic procedure resulted in no recurrence for more than 4 years. Copyright 2007 Wiley-Liss, Inc.

  12. SU-E-I-40: New Method for Measurement of Task-Specific, High-Resolution Detector System Performance

    Energy Technology Data Exchange (ETDEWEB)

    Loughran, B; Singh, V; Jain, A; Bednarek, D; Rudin, S [University at Buffalo, Buffalo, NY (United States)

    2014-06-01

    Purpose: Although generalized linear system analytic metrics such as GMTF and GDQE can evaluate performance of the whole imaging system including detector, scatter and focal-spot, a simplified task-specific measured metric may help to better compare detector systems. Methods: Low quantum-noise images of a neuro-vascular stent with a modified ANSI head phantom were obtained from the average of many exposures taken with the high-resolution Micro-Angiographic Fluoroscope (MAF) and with a Flat Panel Detector (FPD). The square of the Fourier Transform of each averaged image, equivalent to the measured product of the system GMTF and the object function in spatial-frequency space, was then divided by the normalized noise power spectra (NNPS) for each respective system to obtain a task-specific generalized signal-to-noise ratio. A generalized measured relative object detectability (GM-ROD) was obtained by taking the ratio of the integral of the resulting expressions for each detector system to give an overall metric that enables a realistic systems comparison for the given detection task. Results: The GM-ROD provides comparison of relative performance of detector systems from actual measurements of the object function as imaged by those detector systems. This metric includes noise correlations and spatial frequencies relevant to the specific object. Additionally, the integration bounds for the GM-ROD can be selected to emphasis the higher frequency band of each detector if high-resolution image details are to be evaluated. Examples of this new metric are discussed with a comparison of the MAF to the FPD for neuro-vascular interventional imaging. Conclusion: The GM-ROD is a new direct-measured task-specific metric that can provide clinically relevant comparison of the relative performance of imaging systems. Supported by NIH Grant: 2R01EB002873 and an equipment grant from Toshiba Medical Systems Corporation.

  13. Differentiation of IL-17-Producing Invariant Natural Killer T Cells Requires Expression of the Transcription Factor c-Maf

    Directory of Open Access Journals (Sweden)

    Jhang-Sian Yu

    2017-10-01

    Full Text Available c-Maf belongs to the large Maf family of transcription factors and plays a key role in the regulation of cytokine production and differentiation of TH2, TH17, TFH, and Tr1 cells. Invariant natural killer T (iNKT cells can rapidly produce large quantity of TH-related cytokines such as IFN-γ, IL-4, and IL-17A upon stimulation by glycolipid antigens, such as α-galactosylceramide (α-GalCer. However, the role of c-Maf in iNKT cells and iNKT cells-mediated diseases remains poorly understood. In this study, we demonstrate that α-GalCer-stimulated iNKT cells express c-Maf transcript and protein. By using c-Maf-deficient fetal liver cell-reconstituted mice, we further show that c-Maf-deficient iNKT cells produce less IL-17A than their wild-type counterparts after α-GalCer stimulation. While c-Maf deficiency does not affect the development and activation of iNKT cells, c-Maf is essential for the induction of IL-17-producing iNKT (iNKT17 cells by IL-6, TGF-β, and IL-1β, and the optimal expression of RORγt. Accordingly, c-Maf-deficient iNKT17 cells lose the ability to recruit neutrophils into the lungs. Taken together, c-Maf is a positive regulator for the expression of IL-17A and RORγt in iNKT17 cells. It is a potential therapeutic target in iNKT17 cell-mediated inflammatory disease.

  14. Gc protein (vitamin D-binding protein): Gc genotyping and GcMAF precursor activity.

    Science.gov (United States)

    Nagasawa, Hideko; Uto, Yoshihiro; Sasaki, Hideyuki; Okamura, Natsuko; Murakami, Aya; Kubo, Shinichi; Kirk, Kenneth L; Hori, Hitoshi

    2005-01-01

    The Gc protein (human group-specific component (Gc), a vitamin D-binding protein or Gc globulin), has important physiological functions that include involvement in vitamin D transport and storage, scavenging of extracellular G-actin, enhancement of the chemotactic activity of C5a for neutrophils in inflammation and macrophage activation (mediated by a GalNAc-modified Gc protein (GcMAF)). In this review, the structure and function of the Gc protein is focused on especially with regard to Gc genotyping and GcMAF precursor activity. A discussion of the research strategy "GcMAF as a target for drug discovery" is included, based on our own research.

  15. MicroArray Facility: a laboratory information management system with extended support for Nylon based technologies

    Directory of Open Access Journals (Sweden)

    Beaudoing Emmanuel

    2006-09-01

    Full Text Available Abstract Background High throughput gene expression profiling (GEP is becoming a routine technique in life science laboratories. With experimental designs that repeatedly span thousands of genes and hundreds of samples, relying on a dedicated database infrastructure is no longer an option. GEP technology is a fast moving target, with new approaches constantly broadening the field diversity. This technology heterogeneity, compounded by the informatics complexity of GEP databases, means that software developments have so far focused on mainstream techniques, leaving less typical yet established techniques such as Nylon microarrays at best partially supported. Results MAF (MicroArray Facility is the laboratory database system we have developed for managing the design, production and hybridization of spotted microarrays. Although it can support the widely used glass microarrays and oligo-chips, MAF was designed with the specific idiosyncrasies of Nylon based microarrays in mind. Notably single channel radioactive probes, microarray stripping and reuse, vector control hybridizations and spike-in controls are all natively supported by the software suite. MicroArray Facility is MIAME supportive and dynamically provides feedback on missing annotations to help users estimate effective MIAME compliance. Genomic data such as clone identifiers and gene symbols are also directly annotated by MAF software using standard public resources. The MAGE-ML data format is implemented for full data export. Journalized database operations (audit tracking, data anonymization, material traceability and user/project level confidentiality policies are also managed by MAF. Conclusion MicroArray Facility is a complete data management system for microarray producers and end-users. Particular care has been devoted to adequately model Nylon based microarrays. The MAF system, developed and implemented in both private and academic environments, has proved a robust solution for

  16. β-Galactosidase treatment is a common first-stage modification of the three major subtypes of Gc protein to GcMAF.

    Science.gov (United States)

    Uto, Yoshihiro; Yamamoto, Syota; Mukai, Hirotaka; Ishiyama, Noriko; Takeuchi, Ryota; Nakagawa, Yoshinori; Hirota, Keiji; Terada, Hiroshi; Onizuka, Shinya; Hori, Hitoshi

    2012-06-01

    The 1f1f subtype of the group-specific component (Gc) protein is converted into Gc protein-derived macrophage-activating factor (GcMAF) by enzymatic processing with β-galactosidase and sialidase. We previously demonstrated that preGc(1f1f)MAF, a full Gc(1f1f) protein otherwise lacking a galactosyl moiety, can be converted to GcMAF by treatment with mouse peritoneal fluid. Here, we investigated the effects of the β-galactosidase-treated 1s1s and 22 subtypes of Gc protein (preGc(1s1s)MAF and preGc₂₂MAF) on the phagocytic activation of mouse peritoneal macrophages. We demonstrated the presence of Gal-GalNAc disaccharide sugar structures in the Gc(1s1s) protein by western blotting using peanut agglutinin and Helix pomatia agglutinin lectin. We also found that preGc(1s1s)MAF and preGc₂₂MAF significantly enhanced the phagocytic activity of mouse peritoneal macrophages in the presence and absence of mouse peritoneal fluid. We demonstrate that preGc(1s1s)MAF and preGc₂₂MAF proteins can be used as effective macrophage activators.

  17. A comparison of entrance skin dose delivered by clinical angiographic c-arms using the real-time dosimeter: the MOSkin

    International Nuclear Information System (INIS)

    Thorpe, Nathan K.; Cutajar, Dean; Lian, Cheryl; Rosenfeld, Anatoly; Pitney, Mark; Friedman, Daniel; Perevertaylo, Vladimir

    2016-01-01

    measured cine-acquisition entrance dose rate and with the highest measured fluoroscopic entrance dose rate measuring 346 % higher than the lowest measured fluoroscopic entrance dose rate. This comparison of entrance dose delivery across local clinical c-arms demonstrated the disparity in entrance dose delivery across catheterisation laboratories and outlined a need for real-time dose monitoring systems for patients during angiographic procedures. Through use of our calibration method, an average MOSkin calibration of 7.37 mV/cGy was established. The calibration method allowed entrance dose to be measured across a range of beam energies and beam qualities without the input of the c-arm beam characteristics. This calibration factor was proven to reproduce entrance dose values to within 5 % value of the reference dosimeter’s response, suggesting potential for further studies and utilisation of the dosimeter in this field.

  18. Effect of the Gc-derived macrophage-activating factor precursor (preGcMAF) on phagocytic activation of mouse peritoneal macrophages.

    Science.gov (United States)

    Uto, Yoshihiro; Yamamoto, Syota; Takeuchi, Ryota; Nakagawa, Yoshinori; Hirota, Keiji; Terada, Hiroshi; Onizuka, Shinya; Nakata, Eiji; Hori, Hitoshi

    2011-07-01

    The 1f1f subtype of the Gc protein (Gc(1f1f) protein) was converted into Gc-derived macrophage-activating factor (GcMAF) by enzymatic processing in the presence of β-galactosidase of an activated B-cell and sialidase of a T-cell. We hypothesized that preGc(1f1f)MAF, the only Gc(1f1f) protein lacking galactose, can be converted to GcMAF in vivo because sialic acid is cleaved by residual sialidase. Hence, we investigated the effect of preGc(1f1f)MAF on the phagocytic activation of mouse peritoneal macrophages. We examined the sugar moiety of preGc(1f1f)MAF with a Western blot using peanut agglutinin (PNA) and Helix pomatia agglutinin (HPA) lectin. We also found that preGc(1f1f)MAF significantly enhanced phagocytic activity in mouse peritoneal macrophages but only in the presence of the mouse peritoneal fluid; the level of phagocytic activity was the same as that observed for GcMAF. PreGc(1f1f)MAF can be used as an effective macrophage activator in vivo.

  19. Cutting Edge: c-Maf Is Required for Regulatory T Cells To Adopt RORγt+ and Follicular Phenotypes.

    Science.gov (United States)

    Wheaton, Joshua D; Yeh, Chen-Hao; Ciofani, Maria

    2017-12-15

    Regulatory T cells (Tregs) adopt specialized phenotypes defined by coexpression of lineage-defining transcription factors, such as RORγt, Bcl-6, or PPARγ, alongside Foxp3. These Treg subsets have unique tissue distributions and diverse roles in maintaining organismal homeostasis. However, despite extensive functional characterization, the factors driving Treg specialization are largely unknown. In this article, we show that c-Maf is a critical transcription factor regulating this process in mice, essential for generation of both RORγt + Tregs and T follicular regulatory cells, but not for adipose-resident Tregs. c-Maf appears to function primarily in Treg specialization, because IL-10 production, expression of other effector molecules, and general immune homeostasis are not c-Maf dependent. As in other T cells, c-Maf is induced in Tregs by IL-6 and TGF-β, suggesting that a combination of inflammatory and tolerogenic signals promote c-Maf expression. Therefore, c-Maf is a novel regulator of Treg specialization, which may integrate disparate signals to facilitate environmental adaptation. Copyright © 2017 by The American Association of Immunologists, Inc.

  20. Reduced number and morphofunctional change of alveolar macrophages in MafB gene-targeted mice.

    Directory of Open Access Journals (Sweden)

    Michiko Sato-Nishiwaki

    Full Text Available Alveolar macrophages (AMs play an important role in the pathogenesis of chronic obstructive pulmonary disease (COPD. We previously demonstrated that the transcription factor, MafB, increased in the AMs of mice exposed to cigarette smoke, and in those of human patients with COPD. The aim of this study was to evaluate the role of MafB in AMs using newly established transgenic (TG mice that specifically express dominant negative (DN MafB in macrophages under the control of macrophage scavenger receptor (MSR enhancer-promoter. We performed cell differential analyses in bronchoalveolar lavage cells, morphological analyses with electron microscopy, and flow cytometry-based analyses of surface markers and a phagocytic capacity assay in macrophages. AM number in the TG mice was significantly decreased compared with wild-type (WT mice. Morphologically, the high electron density area in the nucleus increased, the shape of pseudopods on the AMs was altered, and actin filament was less localized in the pseudopods of AMs of TG mice, compared with WT mice. The expression of surface markers, F4/80 and CD11b, on peritoneal macrophages in TG mice was reduced compared with WT mice, while those on AMs remained unchanged. Phagocytic capacity was decreased in AMs from TG mice, compared with WT mice. In conclusion, MafB regulates the phenotype of macrophages with respect to the number of alveolar macrophages, the nuclear compartment, cellular shape, surface marker expression, and phagocytic function. MSR-DN MafB TG mice may present a useful model to clarify the precise role of MafB in macrophages.

  1. Clinical experience of integrative cancer immunotherapy with GcMAF.

    Science.gov (United States)

    Inui, Toshio; Kuchiike, Daisuke; Kubo, Kentaro; Mette, Martin; Uto, Yoshihiro; Hori, Hitoshi; Sakamoto, Norihiro

    2013-07-01

    Immunotherapy has become an attractive new strategy in the treatment of cancer. The laboratory and clinical study of cancer immunotherapy is rapidly advancing. However, in the clinical setting, the results of cancer immunotherapy are mixed. We therefore contend that cancer immunotherapy should be customized to each patient individually based on their immune status and propose an integrative immunotherapy approach with second-generation group-specific component macrophage activating factor (GcMAF)-containing human serum. The standard protocol of our integrative cancer immunotherapy is as follows: i) 0.5 ml GcMAF-containing human serum is administered intramuscularly or subcutaneously once or twice per week for the duration of cancer therapy until all cancer cells are eradicated; ii) hyper T/natural killer (NK) cell therapy is given once per week for six weeks; iii) high-dose vitamin C is administered intravenously twice per week; iv) alpha lipoic acid (600 mg) is administered orally daily; v) vitamin D3 (5,000-10,000 IU) is administered orally daily. By March 2013, Saisei Mirai have treated over 345 patients with GcMAF. Among them we here present the cases of three patients for whom our integrative immunotherapy was remarkably effective. The results of our integrative immunotherapy seem hopeful. We also plan to conduct a comparative clinical study.>

  2. Case Report: A Non-small Cell Lung Cancer Patient Treated with GcMAF, Sonodynamic Therapy and Tumor Treating Fields.

    Science.gov (United States)

    Inui, Toshio; Amitani, Haruka; Kubo, Kentaro; Kuchiike, Daisuke; Uto, Yoshihiro; Nishikata, Takahito; Mette, Martin

    2016-07-01

    Macrophage activating factor (MAF)-based immunotherapy has a wide application for use in treating many diseases via macrophage activation. Sonodynamic therapy (SDT) using low-intensity ultrasound and tumor treating field (TTF) therapy are novel therapeutic modalities. SDT is usually combined with ozone therapy to improve local hypoxia within the tumor environment. We treated a 77-year-old male diagnosed with non-small cell lung cancer ((NSCLC) stage 3B) using second-generation serum GcMAF and oral colostrum MAF-based immunotherapy combined with SDT, TTF and ozone therapies. This case report demonstrates that GcMAF, oral colostrum MAF, SDT, TTF and ozone therapy can be used for NSCLC without adverse effects. This case report suggests a new concept of cancer treatment using local destruction of cancer tissue, in this case conducted with SDT and TTF therapy, to be used in combination with serum GcMAF and colostrum MAF immunotherapy as a systemic treatment. Copyright© 2016 International Institute of Anticancer Research (Dr. John G. Delinassios), All rights reserved.

  3. MO-F-CAMPUS-I-02: Occupational Conceptus Doses From Fluoroscopically-Guided Interventional Procedures

    Energy Technology Data Exchange (ETDEWEB)

    Damilakis, J; Perisinakis, K; Solomou, G [University of Crete (Greece); Stratakis, J [University of Crete, Heraklion, Crete (Greece)

    2015-06-15

    Purpose: The aim of this method was to provide dosimetric data on conceptus dose for the pregnant employee who participates in fluoroscopically-guided interventional procedures. Methods: Scattered air-kerma dose rates were obtained for 17 fluoroscopic projections involved in interventional procedures. These projections were simulated on an anthropomorphic phantom placed on the examination table supine. The operating theater was divided into two grids relative to the long table sides. Each grid consisted of 33 cells spaced 0.50 m apart. During the simulated exposures, at each cell, scatter air-kerma rate was measured at 110 cm from the floor i.e. at the height of the waist of the pregnant worker. Air-kerma rates were divided by the dose area product (DAP) rate of each exposure to obtain normalized data. For each projection, measurements were performed for 3 kVp and 3 filtration values i.e. for 9 different x-ray spectra. All measurements were performed by using a modern C-arm angiographic system (Siemens Axiom Artis, Siemens, Germany) and a radiation meter equipped with an ionization chamber. Results: The results consist of 153 iso-dose maps, which show the spatial distribution of DAP-normalized scattered air-kerma doses at the waist level of a pregnant worker. Conceptus dose estimation is possible using air-kerma to embryo/fetal dose conversion coefficients published in a previous study (J Cardiovasc Electrophysiol, Vol. 16, pp. 1–8, July 2005). Using these maps, occupationally exposed pregnant personnel may select a working position for a certain projection that keeps abdominal dose as low as reasonably achievable. Taking into consideration the regulatory conceptus dose limit for occupational exposure, determination of the maximum workload allowed for the pregnant personnel is also possible. Conclusion: Data produced in this work allow for the anticipation of conceptus dose and the determination of the maximum workload for a pregnant worker from any

  4. MO-F-CAMPUS-I-02: Occupational Conceptus Doses From Fluoroscopically-Guided Interventional Procedures

    International Nuclear Information System (INIS)

    Damilakis, J; Perisinakis, K; Solomou, G; Stratakis, J

    2015-01-01

    Purpose: The aim of this method was to provide dosimetric data on conceptus dose for the pregnant employee who participates in fluoroscopically-guided interventional procedures. Methods: Scattered air-kerma dose rates were obtained for 17 fluoroscopic projections involved in interventional procedures. These projections were simulated on an anthropomorphic phantom placed on the examination table supine. The operating theater was divided into two grids relative to the long table sides. Each grid consisted of 33 cells spaced 0.50 m apart. During the simulated exposures, at each cell, scatter air-kerma rate was measured at 110 cm from the floor i.e. at the height of the waist of the pregnant worker. Air-kerma rates were divided by the dose area product (DAP) rate of each exposure to obtain normalized data. For each projection, measurements were performed for 3 kVp and 3 filtration values i.e. for 9 different x-ray spectra. All measurements were performed by using a modern C-arm angiographic system (Siemens Axiom Artis, Siemens, Germany) and a radiation meter equipped with an ionization chamber. Results: The results consist of 153 iso-dose maps, which show the spatial distribution of DAP-normalized scattered air-kerma doses at the waist level of a pregnant worker. Conceptus dose estimation is possible using air-kerma to embryo/fetal dose conversion coefficients published in a previous study (J Cardiovasc Electrophysiol, Vol. 16, pp. 1–8, July 2005). Using these maps, occupationally exposed pregnant personnel may select a working position for a certain projection that keeps abdominal dose as low as reasonably achievable. Taking into consideration the regulatory conceptus dose limit for occupational exposure, determination of the maximum workload allowed for the pregnant personnel is also possible. Conclusion: Data produced in this work allow for the anticipation of conceptus dose and the determination of the maximum workload for a pregnant worker from any

  5. Tumor cell alpha-N-acetylgalactosaminidase activity and its involvement in GcMAF-related macrophage activation.

    Science.gov (United States)

    Mohamad, Saharuddin B; Nagasawa, Hideko; Uto, Yoshihiro; Hori, Hitoshi

    2002-05-01

    Alpha-N-acetyl galactosaminidase (alpha-NaGalase) has been reported to accumulate in serum of cancer patients and be responsible for deglycosylation of Gc protein, which is a precursor of GcMAF-mediated macrophage activation cascade, finally leading to immunosuppression in advanced cancer patients. We studied the biochemical characterization of alpha-NaGalase from several human tumor cell lines. We also examined its effect on the potency of GcMAF to activate mouse peritoneal macrophage to produce superoxide in GcMAF-mediated macrophage activation cascade. The specific activity of alpha-NaGalases from human colon tumor cell line HCT116, human hepatoma cell line HepG2, and normal human liver cells (Chang liver cell line) were evaluated using two types of substrates; GalNAc-alpha-PNP (exo-type substrate) and Gal-beta-GalNAc-alpha-PNP (endo-type substrate). Tumor-derived alpha-NaGalase having higher activity than normal alpha-NaGalase, had higher substrate specificity to the exo-type substrate than to the endo-type substrate, and still maintained its activity at pH 7. GcMAF enhance superoxide production in mouse macrophage, and pre-treatment of GcMAF with tumor cell lysate reduce the activity. We conclude that tumor-derived alpha-NaGalase is different in biochemical characterization compared to normal alpha-NaGalase from normal Chang liver cells. In addition, tumor cell-derived alpha-NaGalase decreases the potency of GcMAF on macrophage activation.

  6. 21 CFR 892.1650 - Image-intensified fluoroscopic x-ray system.

    Science.gov (United States)

    2010-04-01

    ... fluoroscopic x-ray system. (a) Identification. An image-intensified fluoroscopic x-ray system is a device... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Image-intensified fluoroscopic x-ray system. 892... equipment, patient and equipment supports, component parts, and accessories. (b) Classification. Class II...

  7. Comparing radiation exposure during percutaneous vertebroplasty using one- vs. two-fluoroscopic technique

    Directory of Open Access Journals (Sweden)

    Li Yen-Yao

    2013-01-01

    Full Text Available Abstract Background Percutaneous vertebroplasty (PV requires relatively lengthy fluoroscopic guidance, which might lead to substantial radiation exposure to patients or operators. The two-fluoroscopic technique (two-plane radiographs obtained using two fluoroscopes during PV can provide simultaneous two-planar projections with reducing operative time. However, the two-fluoroscopic technique may expose the operator or patient to increased radiation dose. The aim of this study was to quantify the amount of radiation exposure to the patient or operator that occurs during PV using one- vs. two-fluoroscopic technique. Methods Two radiation dosimeters were placed on the right flank of each patient and on the upper sternum of each operator during 26 single-level PV procedures by one senior surgeon. The use of two-fluoroscopic technique (13 patients and one-fluoroscopic technique (13 patients were allocated in a consecutive and alternative manner. The operative time and mean radiation dose to each patient and operator were monitored and compared between groups. Results Mean radiation dose to the patient was 1.97 ± 1.20 mSv (95% CI, 0.71 to 3.23 for the one-fluoroscopic technique group vs. 0.95 ± 0.34 mSv (95% CI, 0.85 to 1.23 for the two-fluoroscopic technique group (P =0.031. Mean radiation dose to the operator was 0.27 ± 0.12 mSv (95% CI, 0.17–0.56 for the one-fluoroscopic technique group vs. 0.25 ± 0.14 mSv (95% CI, 0.06–0.44 for the two-fluoroscopic technique group (P = 0.653. The operative time was significantly different between groups: 47.15 ± 13.48 min (range, 20–75 for the one-fluoroscopic technique group vs. 36.62 ± 8.42 min (range, 21–50 for the two-fluoroscopic technique group (P =0.019. Conclusion Compared to the one-fluoroscopic technique, the two-fluoroscopic technique used during PV provides not only shorter operative times but also reduces the radiation exposure to the patient. There was no

  8. 21 CFR 892.1660 - Non-image-intensified fluoroscopic x-ray system.

    Science.gov (United States)

    2010-04-01

    ... fluoroscopic x-ray system. (a) Identification. A non-image-intensified fluoroscopic x-ray system is a device... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Non-image-intensified fluoroscopic x-ray system... display equipment, patient and equipment supports, component parts, and accessories. (b) Classification...

  9. Radiologist and angiographic procedures. Absorbed radiation dose

    International Nuclear Information System (INIS)

    Tryhus, M.; Mettler, F.A. Jr.; Kelsey, C.

    1987-01-01

    The radiation dose absorbed by the angiographer during angiographic procedures is of vital importance to the radiologist. Nevertheless, most articles on the subject are incomplete, and few measure gonadal dose. In this study, three TLDs were used for each of the following sites: radiologist's eyes, thyroid, gonads with and without shielding apron, and hands. The average dose during carotid angiograms was 2.6, 4.1, 0.4, 4.7, and 7.1 mrads to the eyes, thyroid, gonads with and without .5 mm of lead shielding, and hands, respectively. Average dose during abdominal and peripheral vascular angiographic procedures was 5.2, 7.5, 1.2, 8.5, and 39.9 mrads to the eyes, thyroid, gonads with and without shielding, and hands, respectively. A literature review demonstrates a significant reduction in radiation dose to the angiographer after the advent of automated injectors. Our measured doses for carotid angiography are compatible with contemporary reported values. There was poor correlation with fluoroscopy time and measured dose to the angiographer

  10. Case report: A breast cancer patient treated with GcMAF, sonodynamic therapy and hormone therapy.

    Science.gov (United States)

    Inui, Toshio; Makita, Kaori; Miura, Hirona; Matsuda, Akiko; Kuchiike, Daisuke; Kubo, Kentaro; Mette, Martin; Uto, Yoshihiro; Nishikata, Takahito; Hori, Hitoshi; Sakamoto, Norihiro

    2014-08-01

    Gc protein-derived macrophage-activating factor (GcMAF) occurs naturally in the human body. It has various functions, such as macrophage activation and antitumor activities. Recently, immunotherapy has become an attractive new strategy in the treatment of cancer. GcMAF-based immunotherapy can be combined with many other therapies. Sonodynamic therapy (SDT) using low-intensity ultrasound is a novel therapeutic modality. Ultrasound has been demonstrated to activate a number of sonosensitive agents allowing for the possibility of non-invasive targeted treatment for both superficial and deep-seated tumors. The current case study demonstrates that GcMAF and SDT can be used in combination with conventional therapies in patients with metastatic cancer, especially where treatment options are limited due to factors such as toxicity. This case study also suggests a new concept of cancer treatment using local destruction of cancer tissue, in this case conducted with SDT, to be used in combination with GcMAF immunotherapy as a systemic treatment. Copyright© 2014 International Institute of Anticancer Research (Dr. John G. Delinassios), All rights reserved.

  11. Radiation dose during angiographic procedures

    International Nuclear Information System (INIS)

    Lavoie, Ch.; Rasuli, P.

    2001-01-01

    The use of angiographic procedures is becoming more prevalent as new techniques and equipment are developed. There have been concerns in the scientific community about the level of radiation doses received by patients, and indirectly by staff, during some of these radiological procedures. The purpose of this study was to assess the level of radiation dose from angiographic procedures to patient at the Ottawa Hospital, General Campus. Radiation dose measurements, using Thermo-Luminescent Dosimeters (TLDs), were performed on more than 100 patients on various procedures. The results show that while the patient dose from the great majority of angiographic procedures is less than 2 Gy, a significant number of procedures, especially interventional procedures may have doses greater than 2 Gy and may lead to deterministic effects. (author)

  12. Immunotherapy for Prostate Cancer with Gc Protein-Derived Macrophage-Activating Factor, GcMAF1

    OpenAIRE

    Yamamoto, Nobuto; Suyama, Hirofumi; Yamamoto, Nobuyuki

    2008-01-01

    Serum Gc protein (known as vitamin D3-binding protein) is the precursor for the principal macrophage-activating factor (MAF). The MAF precursor activity of serum Gc protein of prostate cancer patients was lost or reduced because Gc protein was deglycosylated by serum α-N-acetylgalactosaminidase (Nagalase) secreted from cancerous cells. Therefore, macrophages of prostate cancer patients having deglycosylated Gc protein cannot be activated, leading to immunosuppression. Stepwise treatment of pu...

  13. Immunotherapy of HIV-infected patients with Gc protein-derived macrophage activating factor (GcMAF).

    Science.gov (United States)

    Yamamoto, Nobuto; Ushijima, Naofumi; Koga, Yoshihiko

    2009-01-01

    Serum Gc protein (known as vitamin D3-binding protein) is the precursor for the principal macrophage activating factor (MAF). The MAF precursor activity of serum Gc protein of HIV-infected patients was lost or reduced because Gc protein is deglycosylated by alpha-N-acetylgalactosaminidase (Nagalase) secreted from HIV-infected cells. Therefore, macrophages of HIV-infected patients having deglycosylated Gc protein cannot be activated, leading to immunosuppression. Since Nagalase is the intrinsic component of the envelope protein gp120, serum Nagalase activity is the sum of enzyme activities carried by both HIV virions and envelope proteins. These Nagalase carriers were already complexed with anti-HIV immunoglobulin G (IgG) but retained Nagalase activity that is required for infectivity. Stepwise treatment of purified Gc protein with immobilized beta-galactosidase and sialidase generated the most potent macrophage activating factor (termed GcMAF), which produces no side effects in humans. Macrophages activated by administration of 100 ng GcMAF develop a large amount of Fc-receptors as well as an enormous variation of receptors that recognize IgG-bound and unbound HIV virions. Since latently HIV-infected cells are unstable and constantly release HIV virions, the activated macrophages rapidly intercept the released HIV virions to prevent reinfection resulting in exhaustion of infected cells. After less than 18 weekly administrations of 100 ng GcMAF for nonanemic patients, they exhibited low serum Nagalase activities equivalent to healthy controls, indicating eradication of HIV-infection, which was also confirmed by no infectious center formation by provirus inducing agent-treated patient PBMCs. No recurrence occurred and their healthy CD + cell counts were maintained for 7 years.

  14. Quality assurance in diagnostic radiology - assessing the fluoroscopic image quality

    International Nuclear Information System (INIS)

    Tabakov, S.

    1995-01-01

    The X-ray fluoroscopic image has a considerably lower resolution than the radiographic one. This requires a careful quality control aiming at optimal use of the fluoroscopic equipment. The basic procedures for image quality assessment of Image Intensifier/TV image are described. Test objects from Leeds University (UK) are used as prototypes. The results from examining 50 various fluoroscopic devices are shown. Their limiting spatial resolution varies between 0.8 lp/mm (at maximum II field size) and 2.24 lp/mm (at minimum field size). The mean value of the limiting spatial resolution for a 23 cm Image Intensifier is about 1.24 lp/mm. The mean limits of variation of the contrast/detail diagram for various fluoroscopic equipment are graphically expressed. 14 refs., 1 fig. (author)

  15. Prediction of optimal deployment projection for transcatheter aortic valve replacement: angiographic 3-dimensional reconstruction of the aortic root versus multidetector computed tomography.

    Science.gov (United States)

    Binder, Ronald K; Leipsic, Jonathon; Wood, David; Moore, Teri; Toggweiler, Stefan; Willson, Alex; Gurvitch, Ronen; Freeman, Melanie; Webb, John G

    2012-04-01

    Identifying the optimal fluoroscopic projection of the aortic valve is important for successful transcatheter aortic valve replacement (TAVR). Various imaging modalities, including multidetector computed tomography (MDCT), have been proposed for prediction of the optimal deployment projection. We evaluated a method that provides 3-dimensional angiographic reconstructions (3DA) of the aortic root for prediction of the optimal deployment angle and compared it with MDCT. Forty patients undergoing transfemoral TAVR at St Paul's Hospital, Vancouver, Canada, were evaluated. All underwent preimplant 3DA and 68% underwent preimplant MDCT. Three-dimensional angiographic reconstructions were generated from images of a C-arm rotational aortic root angiogram during breath-hold, rapid ventricular pacing, and injection of 32 mL contrast medium at 8 mL/s. Two independent operators prospectively predicted perpendicular valve projections. The implant angle was chosen at the discretion of the physician performing TAVR. The angles from 3DA, from MDCT, the implant angle, and the postdeployment perpendicular prosthesis view were compared. The shortest distance from the postdeployment perpendicular prosthesis projection to the regression line of predicted perpendicular projections was calculated. All but 1 patient had adequate image quality for reproducible angle predictions. There was a significant correlation between 3DA and MDCT for prediction of perpendicular valve projections (r=0.682, Pregression line of predicted angles to the postdeployment prosthesis view was 5.1±4.6° for 3DA and 7.9±4.9° for MDCT (P=0.01). Three-dimensional angiographic reconstructions and MDCT are safe, practical, and accurate imaging modalities for identifying the optimal perpendicular valve deployment projection during TAVR.

  16. Genetic interactions of MAF1 identify a role for Med20 in transcriptional repression of ribosomal protein genes.

    Directory of Open Access Journals (Sweden)

    Ian M Willis

    2008-07-01

    Full Text Available Transcriptional repression of ribosomal components and tRNAs is coordinately regulated in response to a wide variety of environmental stresses. Part of this response involves the convergence of different nutritional and stress signaling pathways on Maf1, a protein that is essential for repressing transcription by RNA polymerase (pol III in Saccharomyces cerevisiae. Here we identify the functions buffering yeast cells that are unable to down-regulate transcription by RNA pol III. MAF1 genetic interactions identified in screens of non-essential gene-deletions and conditionally expressed essential genes reveal a highly interconnected network of 64 genes involved in ribosome biogenesis, RNA pol II transcription, tRNA modification, ubiquitin-dependent proteolysis and other processes. A survey of non-essential MAF1 synthetic sick/lethal (SSL genes identified six gene-deletions that are defective in transcriptional repression of ribosomal protein (RP genes following rapamycin treatment. This subset of MAF1 SSL genes included MED20 which encodes a head module subunit of the RNA pol II Mediator complex. Genetic interactions between MAF1 and subunits in each structural module of Mediator were investigated to examine the functional relationship between these transcriptional regulators. Gene expression profiling identified a prominent and highly selective role for Med20 in the repression of RP gene transcription under multiple conditions. In addition, attenuated repression of RP genes by rapamycin was observed in a strain deleted for the Mediator tail module subunit Med16. The data suggest that Mediator and Maf1 function in parallel pathways to negatively regulate RP mRNA and tRNA synthesis.

  17. Association of the macrophage activating factor (MAF) precursor activity with polymorphism in vitamin D-binding protein.

    Science.gov (United States)

    Nagasawa, Hideko; Sasaki, Hideyuki; Uto, Yoshihiro; Kubo, Shinichi; Hori, Hitoshi

    2004-01-01

    Serum vitamin D-binding protein (Gc protein or DBP) is a highly expressed polymorphic protein, which is a precursor of the inflammation-primed macrophage activating factor, GcMAF, by a cascade of carbohydrate processing reactions. In order to elucidate the relationship between Gc polymorphism and GcMAF precursor activity, we estimated the phagocytic ability of three homotypes of Gc protein, Gc1F-1F, Gc1S-1S and Gc2-2, through processing of their carbohydrate moiety. We performed Gc typing of human serum samples by isoelectric focusing (IEF). Gc protein from human serum was purified by affinity chromatography with 25-hydroxyvitamin D3-sepharose. A phagocytosis assay of Gc proteins, modified using beta-glycosidase and sialidase, was carried out. The Gc1F-1F phenotype was revealed to possess Galbeta1-4GalNAc linkage by the analysis of GcMAF precursor activity using beta1-4 linkage-specific galactosidase from jack bean. The GcMAF precursor activity of the Gc1F-1F phenotype was highest among three Gc homotypes. The Gc polymorphism and carbohydrate diversity of Gc protein are significant for its pleiotropic effects.

  18. Pre-procedural scout radiographs are unnecessary for routine pediatric fluoroscopic examinations

    Energy Technology Data Exchange (ETDEWEB)

    Creeden, Sean G.; Rao, Anil G.; Eklund, Meryle J.; Hill, Jeanne G.; Thacker, Paul G. [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States)

    2017-03-15

    Although practice patterns vary, scout radiographs are often routinely performed with pediatric fluoroscopic studies. However few studies have evaluated their utility in routine pediatric fluoroscopy. To evaluate the value of scout abdomen radiographs in routine barium or water-soluble enema, upper gastrointestinal (GI) series, and voiding cystourethrogram pediatric fluoroscopic procedures. We retrospectively evaluated 723 barium or water-soluble enema, upper GI series, and voiding cystourethrogram fluoroscopic procedures performed at our institution. We assessed patient history and demographics, clinical indication for the examination, prior imaging findings and impressions, scout radiograph findings, additional findings provided by the scout radiograph that were previously unknown, and whether the scout radiograph contributed any findings that significantly changed management. We retrospectively evaluated 723 fluoroscopic studies (368 males and 355 females) in pediatric patients. Of these, 700 (96.8%) had a preliminary scout radiograph. Twenty-three (3.2%) had a same-day radiograph substituted as a scout radiograph. Preliminary scout abdomen radiographs/same-day radiographs showed no new significant findings in 719 (99.4%) studies. New but clinically insignificant findings were seen in 4 (0.6%) studies and included umbilical hernia, inguinal hernia and hip dysplasia. No findings were found on the scout radiographs that would either alter the examination performed or change management with regard to the exam. Pre-procedural scout abdomen radiographs are unnecessary in routine barium and water-soluble enema, upper GI series, and voiding cystourethrogram pediatric fluoroscopic procedures and can be substituted with a spot fluoroscopic last-image hold. (orig.)

  19. Angiographic appearances of rare renal tumours

    International Nuclear Information System (INIS)

    Schmidt, M.; Taenzer, V.

    1980-01-01

    Oncocytomas, called oxyphil proximal tubular adenomas in the Anglo Saxon literature, and benign hypernephromas are non-malignant, usually symptomless, rare tumours belonging to the renal adenomas. Oncocytomas have angiographic appearances sufficiently uniform to permit a tentative diagnosis. Histologically benign hypernephromas do not possess characteristic angiographic appearances and, in the presence of tumour in the renal vein or necrotic avascular areas, must be regarded as potentially malignant. (orig.) [de

  20. Is chondroitin sulfate responsible for the biological effects attributed to the GC protein-derived Macrophage Activating Factor (GcMAF)?

    Science.gov (United States)

    Ruggiero, Marco; Reinwald, Heinz; Pacini, Stefania

    2016-09-01

    We hypothesize that a plasma glycosaminoglycan, chondroitin sulfate, may be responsible for the biological and clinical effects attributed to the Gc protein-derived Macrophage Activating Factor (GcMAF), a protein that is extracted from human blood. Thus, Gc protein binds chondroitin sulfate on the cell surface and such an interaction may occur also in blood, colostrum and milk. This interpretation would solve the inconsistencies encountered in explaining the effects of GcMAF in vitro and in vivo. According to our model, the Gc protein or the GcMAF bind to chondroitin sulfate both on the cell surface and in bodily fluids, and the resulting multimolecular complexes, under the form of oligomers trigger a transmembrane signal or, alternatively, are internalized and convey the signal directly to the nucleus thus eliciting the diverse biological effects observed for both GcMAF and chondroitin sulfate. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. Gc protein-derived macrophage-activating factor (GcMAF) stimulates cAMP formation in human mononuclear cells and inhibits angiogenesis in chick embryo chorionallantoic membrane assay.

    Science.gov (United States)

    Pacini, Stefania; Morucci, Gabriele; Punzi, Tiziana; Gulisano, Massimo; Ruggiero, Marco

    2011-04-01

    The effects of Gc protein-derived macrophage-activating factor (GcMAF) have been studied in cancer and other conditions where angiogenesis is deregulated. In this study, we demonstrate for the first time that the mitogenic response of human peripheral blood mononuclear cells (PBMCs) to GcMAF was associated with 3'-5'-cyclic adenosine monophosphate (cAMP) formation. The effect was dose dependent, and maximal stimulation was achieved using 0.1 ng/ml. Heparin inhibited the stimulatory effect of GcMAF on PBMCs. In addition, we demonstrate that GcMAF (1 ng/ml) inhibited prostaglandin E(1)- and human breast cancer cell-stimulated angiogenesis in chick embryo chorionallantoic membrane (CAM) assay. Finally, we tested different GcMAF preparations on CAM, and the assay proved to be a reliable, reproducible and inexpensive method to determine the relative potencies of different preparations and their stability; we observed that storage at room temperature for 15 days decreased GcMAF potency by about 50%. These data could prove useful for upcoming clinical trials on GcMAF.

  2. Petrology and geochemistry of REE-rich Mafé banded iron formations (Bafia group, Cameroon)

    Science.gov (United States)

    Nkoumbou, Charles; Gentry, Fuh Calistus; Tchakounte Numbem, Jacqueline; Belle Ekwe Lobé, Yolande Vanessa; Nwagoum Keyamfé, Christin Steve

    2017-07-01

    Archaean-Paleoproterozoic foliated amphibole-gneisses and migmatites interstratified with amphibolites, pyroxeno-amphibolites and REE-rich banded-iron formations outcrop at Mafé, Ndikinimeki area. The foliation is nearly vertical due to tight folds. Flat-lying quartz-rich mica schists and quartzites, likely of Pan-African age, partly cover the formations. Among the Mafé BIFs, the oxide BIF facies shows white layers of quartz and black layers of magnetite and accessory hematite, whereas the silicate BIF facies is made up of thin discontinuous quartz layers alternating with larger garnet (almandine-spessartine) + chamosite + ilmenite ± Fe-talc layers. REE-rich oxide BIFs compositions are close to the East Pacific Rise (EPR) hydrothermal deposit; silicate BIFs plot midway between EPR and the associated amphibolite, accounting for a contamination by volcanic materials, in addition to the hydrothermal influence during their oceanic deposition. The association of an oceanic setting with alkaline and tholeiitic magmatism is typical of the Algoma-type BIF deposit. The REE-rich BIFs indices recorded at Mafé are interpreted as resulting from an Archaean-Paleoproterozoic mineralization.

  3. An LPV Adaptive Observer for Updating a Map Applied to an MAF Sensor in a Diesel Engine.

    Science.gov (United States)

    Liu, Zhiyuan; Wang, Changhui

    2015-10-23

    In this paper, a new method for mass air flow (MAF) sensor error compensation and an online updating error map (or lookup table) due to installation and aging in a diesel engine is developed. Since the MAF sensor error is dependent on the engine operating point, the error model is represented as a two-dimensional (2D) map with two inputs, fuel mass injection quantity and engine speed. Meanwhile, the 2D map representing the MAF sensor error is described as a piecewise bilinear interpolation model, which can be written as a dot product between the regression vector and parameter vector using a membership function. With the combination of the 2D map regression model and the diesel engine air path system, an LPV adaptive observer with low computational load is designed to estimate states and parameters jointly. The convergence of the proposed algorithm is proven under the conditions of persistent excitation and given inequalities. The observer is validated against the simulation data from engine software enDYNA provided by Tesis. The results demonstrate that the operating point-dependent error of the MAF sensor can be approximated acceptably by the 2D map from the proposed method.

  4. Effect of paricalcitol and GcMAF on angiogenesis and human peripheral blood mononuclear cell proliferation and signaling.

    Science.gov (United States)

    Pacini, Stefania; Morucci, Gabriele; Punzi, Tiziana; Gulisano, Massimo; Ruggiero, Marco; Amato, Marcello; Aterini, Stefano

    2012-01-01

    In addition to its role in calcium homeostasis and bone mineralization, vitamin D is involved in immune defence, cardiovascular function, inflammation and angiogenesis, and these pleiotropic effects are of interested in the treatment of chronic kidney disease. Here we investigated the effects of paricalcitol, a nonhypercalcemic vitamin D analogue, on human peripheral blood mononuclear cell proliferation and signaling, and on angiogenesis. These effects were compared with those of a known inhibitor of angiogenesis pertaining to the vitamin D axis, the vitamin D-binding protein-derived Gc-macrophage activating factor (GcMAF). Since the effects of vitamin D receptor agonists are associated with polymorphisms of the gene coding for the receptor, we measured the effects of both compounds on mononuclear cells harvested from subjects harboring different BsmI polymorphisms. Paricalcitol inhibited mononuclear cell viability with the bb genotype showing the highest effect. GcMAF, on the contrary, stimulated cell proliferation, with the bb genotype showing the highest stimulatory effect. Both compounds stimulated 3'-5'-cyclic adenosine monophosphate formation in mononuclear cells with the highest effect on the bb genotype. Paricalcitol and GcMAF inhibited the angiogenesis induced by proinflammatory prostaglandin E1. Polymorphisms of the vitamin D receptor gene, known to be associated with the highest responses to vitamin D receptor agonists, are also associated with the highest responses to GcMAF. These results highlight the role of the vitamin D axis in chronic kidney disease, an axis which includes vitamin D, its receptor and vitamin D-binding protein-derived GcMAF.

  5. Angiographic findings of congenital vascular malformation in soft tissue

    International Nuclear Information System (INIS)

    Choi, Dae Seob; Park, Jae Hyung; Han, Joon Koo; Chung, Jin Wook; Moon, Woo Kyung; Han, Man Chung

    1994-01-01

    We evaluated the clinical, plain radiographic, and angiographic findings of congenital vascular malformation of the soft tissue. Retrospective analysis was performed in 36 patients. Pathological diagnosis was done in 25 patients by surgery and the others were clinically and angiographically diagnosed. On the basis of angiographic findings, we classified the lesions to three groups as arteriovenous malformation (AVM), hemangioma, and venous malformation. In pathologically proven 25 cases, we compared the angiographic diagnosis with the pathologic diagnosis. By angiographic classification, AVM was 13 cases, hemangioma 16 cases, and venous malformation 7 cases. The locations of the lesions were upper extremities in 14 cases, lower extremities in 20 cases, both extremities in 1 case, and back in 1 case. Clinical findings were bruit and thrill in 13 cases(12 AVMs,1 hemangioma) and varicosities in 16 cases(11 AVMs, 3 hemangiomas and 2 venous malformations). The varicosities in AVM were pulsating nature, but not in hemangioma and venous malformation. The concordance rate of the angiographic and pathologic diagnosis was 100%(6/6) in AVM, 71%(10/14) in hemangioma and 60% (3/5) in venous malformation. We think that angiography is an essential study for accurate diagnosis and appropriate treatment of congenital vascular malformation

  6. WE-DE-207A-01: Parallels in the Evolution of X-Ray Angiographic Systems and Devices Used for Minimally Invasive Endovascular Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Strother, C. [University of Wisconsin (United States)

    2016-06-15

    pursued. For the highest spatial and temporal resolution, x-ray guidance with fluoroscopy and angiography although dominant are still being vastly improved. New detectors such as the Micro-Angiographic Fluoroscope (MAF) and x-ray source designs that enable higher outputs while maintaining small focal spots will be highlighted along with new methods for minimizing the radiation dose to patients. Additionally, new platforms for training and device testing that include patient-specific 3D printed vascular phantoms and new metrics such as generalized relative object detectability for objectively inter-comparing systems will be discussed. This will improve the opportunity for better evaluation of these technological advances which should contribute to the safety and efficacy of image guided minimally invasive neuro-endovascular procedures. Learning Objectives: To understand the operation of new x-ray imaging chain components such as detectors and sources To be informed about the latest testing methods, with 3D printed vascular phantoms, and new evaluation metrics for advanced imaging in x-ray image guided neurovascular interventions Advances in cone beam CT anatomical and functional imaging in angio-suite to enable one-stop-shop stroke imaging workflow Guang-Hong Chen - The introduction of flat-panel detector based cone-beam CT in clinical angiographic imaging systems enabled treating physicians to obtain three-dimensional anatomic roadmaps for bony structure, soft brain tissue, and vasculatures for treatment planning and efficacy checking after the procedures. However, much improvement is needed to reduce image artifacts, reduce radiation dose, and add potential functional imaging capability to provide four-dimensional dynamic information of vasculature and brain perfusion. In this presentation, some of the new techniques developed to address radiation dose issues, image artifact reduction and brain perfusion using C-arm cone-beam CT imaging system will be introduced for the

  7. WE-DE-207A-01: Parallels in the Evolution of X-Ray Angiographic Systems and Devices Used for Minimally Invasive Endovascular Therapy

    International Nuclear Information System (INIS)

    Strother, C.

    2016-01-01

    pursued. For the highest spatial and temporal resolution, x-ray guidance with fluoroscopy and angiography although dominant are still being vastly improved. New detectors such as the Micro-Angiographic Fluoroscope (MAF) and x-ray source designs that enable higher outputs while maintaining small focal spots will be highlighted along with new methods for minimizing the radiation dose to patients. Additionally, new platforms for training and device testing that include patient-specific 3D printed vascular phantoms and new metrics such as generalized relative object detectability for objectively inter-comparing systems will be discussed. This will improve the opportunity for better evaluation of these technological advances which should contribute to the safety and efficacy of image guided minimally invasive neuro-endovascular procedures. Learning Objectives: To understand the operation of new x-ray imaging chain components such as detectors and sources To be informed about the latest testing methods, with 3D printed vascular phantoms, and new evaluation metrics for advanced imaging in x-ray image guided neurovascular interventions Advances in cone beam CT anatomical and functional imaging in angio-suite to enable one-stop-shop stroke imaging workflow Guang-Hong Chen - The introduction of flat-panel detector based cone-beam CT in clinical angiographic imaging systems enabled treating physicians to obtain three-dimensional anatomic roadmaps for bony structure, soft brain tissue, and vasculatures for treatment planning and efficacy checking after the procedures. However, much improvement is needed to reduce image artifacts, reduce radiation dose, and add potential functional imaging capability to provide four-dimensional dynamic information of vasculature and brain perfusion. In this presentation, some of the new techniques developed to address radiation dose issues, image artifact reduction and brain perfusion using C-arm cone-beam CT imaging system will be introduced for the

  8. A rapid method of evaluating fluoroscopic system performance

    International Nuclear Information System (INIS)

    Sprawls, P.

    1989-01-01

    This paper presents a study to develop a method for the rapid evaluation and documentation of fluoroscopic image quality. All objects contained within a conventional contrast-detail test phantom (Leeds TO-10) are displayed in an array format according to their contrast and size. A copy of the display is used as the data collection form and a permanent record of system performance. A fluoroscope is evaluated by viewing the test phantom and marking the visible objects on the display. A line drawn through the objects with minimum visibility in each size group forms a contrast-detail curve for the system. This is compared with a standard or reference line, which is in the display.Deviations in curve position are useful indicators of specific image quality problems, such as excessive noise or blurring. The use of a special object-visibility array format display makes it possible to collect data, analyze the results, and create a record of fluoroscopic performance in less than 2 minutes for each viewing mode

  9. Angiographic diagnosis of the carotid artery pseudoaneurysm

    International Nuclear Information System (INIS)

    Qi Yueyong; Zou Liguang; Dai Shuhua; Tan Yinghui; Li Zhongyu; Zhou Zheng

    2004-01-01

    Objective: To create a further understanding of the angiographic features of the carotid artery pseudoaneurysm (CAPA) and to explore the clinical diagnostic value of angiography. Methods: Sixteen cases of CAPA with clinical and angiographic data were analyzed retrospectively. The angiographic appearances in all of the patients were observed dynamically and precisely with a double blind method by two experienced radiologists together and formed a consensus interpretation. Results: Angiography provided a definite diagnosis for all cases. The parent arteries included the common carotid artery (1 case), common carotid artery bifurcation (9 cases), internal carotid artery (5 cases) and external carotid artery (1 case). The angiographic features of the CAPA were: All cases showed the contrast media retension in the aneurysms; turbulent flow within aneurysm in 9 cases; the 'jetting sign' at the leak of the parent artery in 7 cases; increase angulation of the bifurcation of internal and external carotid arteries in 12 cases. Conclusions: Angiography is the most valuable examination method in diagnosis of CAPA, and it can not only provide definite diagnosis, but also play an important role in selection of therapeutic plan. (authors)

  10. Mutation update of transcription factor genes FOXE3, HSF4, MAF, and PITX3 causing cataracts and other developmental ocular defects.

    Science.gov (United States)

    Anand, Deepti; Agrawal, Smriti A; Slavotinek, Anne; Lachke, Salil A

    2018-04-01

    Mutations in the transcription factor genes FOXE3, HSF4, MAF, and PITX3 cause congenital lens defects including cataracts that may be accompanied by defects in other components of the eye or in nonocular tissues. We comprehensively describe here all the variants in FOXE3, HSF4, MAF, and PITX3 genes linked to human developmental defects. A total of 52 variants for FOXE3, 18 variants for HSF4, 20 variants for MAF, and 19 variants for PITX3 identified so far in isolated cases or within families are documented. This effort reveals FOXE3, HSF4, MAF, and PITX3 to have 33, 16, 18, and 7 unique causal mutations, respectively. Loss-of-function mutant animals for these genes have served to model the pathobiology of the associated human defects, and we discuss the currently known molecular function of these genes, particularly with emphasis on their role in ocular development. Finally, we make the detailed FOXE3, HSF4, MAF, and PITX3 variant information available in the Leiden Online Variation Database (LOVD) platform at https://www.LOVD.nl/FOXE3, https://www.LOVD.nl/HSF4, https://www.LOVD.nl/MAF, and https://www.LOVD.nl/PITX3. Thus, this article informs on key variants in transcription factor genes linked to cataract, aphakia, corneal opacity, glaucoma, microcornea, microphthalmia, anterior segment mesenchymal dysgenesis, and Ayme-Gripp syndrome, and facilitates their access through Web-based databases. © 2018 Wiley Periodicals, Inc.

  11. Identification of a novel missense mutation of MAF in a Japanese family with congenital cataract by whole exome sequencing: a clinical report and review of literature.

    Science.gov (United States)

    Narumi, Yoko; Nishina, Sachiko; Tokimitsu, Motoharu; Aoki, Yoko; Kosaki, Rika; Wakui, Keiko; Azuma, Noriyuki; Murata, Toshinori; Takada, Fumio; Fukushima, Yoshimitsu; Kosho, Tomoki

    2014-05-01

    Congenital cataracts are the most important cause of severe visual impairment in infants. Genetic factors contribute to the disease development and 29 genes are known to cause congenital cataracts. Identifying the genetic cause of congenital cataracts can be difficult because of genetic heterogeneity. V-maf avian musculoaponeurotic fibrosarcoma oncogene homolog (MAF) encodes a basic region/leucine zipper transcription factor that plays a key role as a regulator of embryonic lens fiber cell development. MAF mutations have been reported to cause juvenile-onset pulverulent cataract, microcornea, iris coloboma, and other anterior segment dysgenesis. We report on six patients in a family who have congenital cataracts were identified MAF mutation by whole exome sequencing (WES). The heterozygous MAF mutation Q303L detected in the present family occurs in a well conserved glutamine residue at the basic region of the DNA-binding domain. All affected members showed congenital cataracts. Three of the six members showed microcornea and one showed iris coloboma. Congenital cataracts with MAF mutation exhibited phenotypically variable cataracts within the family. Review of the patients with MAF mutations supports the notion that congenital cataracts caused by MAF mutations could be accompanied by microcornea and/or iris coloboma. WES is a useful tool for detecting disease-causing mutations in patients with genetically heterogeneous conditions. © 2014 Wiley Periodicals, Inc.

  12. Angiographic features of rapidly involuting congenital hemangioma (RICH)

    Energy Technology Data Exchange (ETDEWEB)

    Konez, Orhan; Burrows, Patricia E. [Department of Radiology, Children' s Hospital Boston, Harvard Medical School, 300 Longwood Avenue, Boston, MA 02115 (United States); Mulliken, John B. [Division of Plastic Surgery, Children' s Hospital Boston, Harvard Medical School, 300 Longwood Avenue, Boston, MA 02115 (United States); Fishman, Steven J. [Department of Pediatric Surgery, Children' s Hospital Boston, Harvard Medical School, 300 Longwood Avenue, Boston, MA 02115 (United States); Kozakewich, Harry P.W. [Department of Pathology, Children' s Hospital Boston, Harvard Medical School, 300 Longwood Avenue, Boston, MA 02115 (United States)

    2003-01-01

    Rapidly involuting congenital hemangioma (RICH) is a recently recognized entity in which the vascular tumor is fully developed at birth and undergoes rapid involution. Angiographic findings in two infants with congenital hemangioma are reported and compared with a more common postnatal infantile hemangioma and a congenital infantile fibrosarcoma. Congenital hemangiomas differed from infantile hemangiomas angiographically by inhomogeneous parenchymal staining, large and irregular feeding arteries in disorganized patterns, arterial aneurysms, direct arteriovenous shunts, and intravascular thrombi. Both infants had clinical evidence of a high-output cardiac failure and intralesional bleeding. This congenital high-flow vascular tumor is difficult to distinguish angiographically from arteriovenous malformation and congenital infantile fibrosarcoma. (orig.)

  13. The in vitro GcMAF effects on endocannabinoid system transcriptionomics, receptor formation, and cell activity of autism-derived macrophages

    Science.gov (United States)

    2014-01-01

    Background Immune system dysregulation is well-recognized in autism and thought to be part of the etiology of this disorder. The endocannabinoid system is a key regulator of the immune system via the cannabinoid receptor type 2 (CB2R) which is highly expressed on macrophages and microglial cells. We have previously published significant differences in peripheral blood mononuclear cell CB2R gene expression in the autism population. The use of the Gc protein-derived Macrophage Activating Factor (GcMAF), an endogenous glycosylated vitamin D binding protein responsible for macrophage cell activation has demonstrated positive effects in the treatment of autistic children. In this current study, we investigated the in vitro effects of GcMAF treatment on the endocannabinoid system gene expression, as well as cellular activation in blood monocyte-derived macrophages (BMDMs) from autistic patients compared to age-matched healthy developing controls. Methods To achieve these goals, we used biomolecular, biochemical and immunocytochemical methods. Results GcMAF treatment was able to normalize the observed differences in dysregulated gene expression of the endocannabinoid system of the autism group. GcMAF also down-regulated the over-activation of BMDMs from autistic children. Conclusions This study presents the first observations of GcMAF effects on the transcriptionomics of the endocannabinoid system and expression of CB2R protein. These data point to a potential nexus between endocannabinoids, vitamin D and its transporter proteins, and the immune dysregulations observed with autism. PMID:24739187

  14. The in vitro GcMAF effects on endocannabinoid system transcriptionomics, receptor formation, and cell activity of autism-derived macrophages.

    Science.gov (United States)

    Siniscalco, Dario; Bradstreet, James Jeffrey; Cirillo, Alessandra; Antonucci, Nicola

    2014-04-17

    Immune system dysregulation is well-recognized in autism and thought to be part of the etiology of this disorder. The endocannabinoid system is a key regulator of the immune system via the cannabinoid receptor type 2 (CB2R) which is highly expressed on macrophages and microglial cells. We have previously published significant differences in peripheral blood mononuclear cell CB2R gene expression in the autism population. The use of the Gc protein-derived Macrophage Activating Factor (GcMAF), an endogenous glycosylated vitamin D binding protein responsible for macrophage cell activation has demonstrated positive effects in the treatment of autistic children. In this current study, we investigated the in vitro effects of GcMAF treatment on the endocannabinoid system gene expression, as well as cellular activation in blood monocyte-derived macrophages (BMDMs) from autistic patients compared to age-matched healthy developing controls. To achieve these goals, we used biomolecular, biochemical and immunocytochemical methods. GcMAF treatment was able to normalize the observed differences in dysregulated gene expression of the endocannabinoid system of the autism group. GcMAF also down-regulated the over-activation of BMDMs from autistic children. This study presents the first observations of GcMAF effects on the transcriptionomics of the endocannabinoid system and expression of CB2R protein. These data point to a potential nexus between endocannabinoids, vitamin D and its transporter proteins, and the immune dysregulations observed with autism.

  15. Fluoroscopic Imaging Systems. Chapter 8

    Energy Technology Data Exchange (ETDEWEB)

    Jones, A. K. [University of Texas MD Anderson Cancer Center, Houston (United States)

    2014-09-15

    Fluoroscopy refers to the use of an X ray beam and a suitable image receptor for viewing images of processes or instruments in the body in real time. Fluoroscopic imaging trades the high signal to noise ratio (SNR) of radiography for high temporal resolution, as factors that maintain patient dose at an acceptable level must be used.

  16. Exposure doses to angiographers during interventional angiography

    International Nuclear Information System (INIS)

    Fukutomi, Yukimi; Yasuhara, Yoshifumi; Sugata, Shigenori; Fujii, Takashi; Kawakami, Toshiaki; Ikezoe, Junpei

    1997-01-01

    We report the exposure doses to angiographers during interventional angiography and the protective efficacy of protective aprons against X-rays in this study. The first (main) angiographer was exposed to the maximum dose of 1 μSv/min at the left chest area and lower abdominal area inside the protective apron. The second (assistant) angiographer was exposed to the maximum dose of 2 μSv/min at the left chest area and 1 μSv/min at the lower abdominal area. X-ray transmission ratio of the protective apron was 4.9 percent or less for UL25L, O percent for 0.35 mmPb and 4.3 percent or less for 0.5 mmPb. These results were lower than the dose equivalent limit based on the laws and ordinances. The protection capacities of these protective aprons proved to be sufficient. The exposure dose at the left extremity area outside the protective apron, however, was 24 times higher than at the left chest area inside. The data showed that it was not protected from scattered X-rays outside the protective apron. It is imperative to consider secondary protective material for the area outside the protective apron. Considering the risk of radiation, we need to better control exposure to angiographers. (author)

  17. Intracranial meningeal masson's hemangioma: CT and angiographic features

    International Nuclear Information System (INIS)

    Chang, Kee Hyun; Chi, Je Gen; Han, Man Chung; Cho, Byung Kyu; Kim, Hyun Jip

    1985-01-01

    Masson's hemangioma is a rare benign vascular condition with a papillary intravascular endothelial proliferation which may appear either as a primary form as a secondary form in a pre-existing vascular process. CT and angiographic features of 2 cases with Masson's hemangioma were presented. Both of them were located extra-axially in the posterior fossa. CT findings were not specific in both cases; One showed homogeneously enhancing mass, simulating meningioma. And the other demonstrated a multiocular rim enhancing mass. However, the angiographic features were rather characteristic; Both cases showed persistent vascular poolings of contrast media which were supplied form the meningeal vessels. Angiographic differential diagnosis of similar lesions in the posterior fossa is discussed

  18. Clinical application of digital angiographic system DIGITEX2400

    Energy Technology Data Exchange (ETDEWEB)

    Kawai, Masumi; Tanaka, Shuji; Fujino, Yoshiyuki; Yasumi, Masayuki (Shimadzu Corp., Kyoto (Japan))

    1992-10-01

    Digital angiography (DA) has been of widespread use clinically, and it has attracted considerable attention in angiographic examination today. And under the condition of the spread of interventional angiography, not only high quality image but also ease of operation are required to the system. The clinical usefullness of digital angiographic system DIGITEX2400 are reported in this paper. (author).

  19. Clinical application of digital angiographic system DIGITEX2400

    International Nuclear Information System (INIS)

    Kawai, Masumi; Tanaka, Shuji; Fujino, Yoshiyuki; Yasumi, Masayuki

    1992-01-01

    Digital angiography (DA) has been of widespread use clinically, and it has attracted considerable attention in angiographic examination today. And under the condition of the spread of interventional angiography, not only high quality image but also ease of operation are required to the system. The clinical usefullness of digital angiographic system DIGITEX2400 are reported in this paper. (author)

  20. Objective masurement of image quality in fluoroscopic x-ray equipment FluoroQuality

    CERN Document Server

    Tapiovaara, M

    2003-01-01

    The report describes FluoroQuality, a computer program that is developed in STUK and used for measuring the image quality in medical fluoroscopic equipment. The method is based on the statistical decision theory (SDT) and the main measurement result is given in terms of the accumulation rate of the signal-to-noise ratio squared (SNR sup 2 sub r sub a sub t sub e). In addition to this quantity several other quantities are measured. These quantities include the SNR of single image frames, the spatio-temporal noise power spectrum and the temporal lag. The measurement method can be used, for example, for specifying the image quality in fluoroscopic images, for optimising the image quality and dose rate in fluoroscopy and for quality control of fluoroscopic equipment. The theory behind the measurement method is reviewed and the measurement of the various quantities is explained. An example of using the method for optimising a specified fluoroscopic procedure is given. The User's Manual of the program is included a...

  1. Myelo-erythroid commitment after burn injury is under β-adrenergic control via MafB regulation.

    Science.gov (United States)

    Hasan, Shirin; Johnson, Nicholas B; Mosier, Michael J; Shankar, Ravi; Conrad, Peggie; Szilagyi, Andrea; Gamelli, Richard L; Muthumalaiappan, Kuzhali

    2017-03-01

    Severely injured burn patients receive multiple blood transfusions for anemia of critical illness despite the adverse consequences. One limiting factor to consider alternate treatment strategies is the lack of a reliable test platform to study molecular mechanisms of impaired erythropoiesis. This study illustrates how conditions resulting in a high catecholamine microenvironment such as burns can instigate myelo-erythroid reprioritization influenced by β-adrenergic stimulation leading to anemia. In a mouse model of scald burn injury, we observed, along with a threefold increase in bone marrow LSK cells (lin neg Sca1 + cKit + ), that the myeloid shift is accompanied with a significant reduction in megakaryocyte erythrocyte progenitors (MEPs). β-Blocker administration (propranolol) for 6 days after burn, not only reduced the number of LSKs and MafB + cells in multipotent progenitors, but also influenced myelo-erythroid bifurcation by increasing the MEPs and reducing the granulocyte monocyte progenitors in the bone marrow of burn mice. Furthermore, similar results were observed in burn patients' peripheral blood mononuclear cell-derived ex vivo culture system, demonstrating that commitment stage of erythropoiesis is impaired in burn patients and intervention with propranolol (nonselective β1,2-adrenergic blocker) increases MEPs. Also, MafB + cells that were significantly increased following standard burn care could be mitigated when propranolol was administered to burn patients, establishing the mechanistic regulation of erythroid commitment by myeloid regulatory transcription factor MafB. Overall, results demonstrate that β-adrenergic blockers following burn injury can redirect the hematopoietic commitment toward erythroid lineage by lowering MafB expression in multipotent progenitors and be of potential therapeutic value to increase erythropoietin responsiveness in burn patients. Copyright © 2017 the American Physiological Society.

  2. Angiographic diagnosis and treatment of gastrointestinal bleeding

    International Nuclear Information System (INIS)

    Park, Jae Hyung; Sung, Kyu Bo; Koo, Kyung Hoi; Bae, Tae Young; Chung, Eun Chul; Han, Man Chung

    1986-01-01

    Diagnostic angiographic evaluations were done in 33 patients with gastrointestinal bleeding for recent 5 years at Department of Radiology, Seoul National University Hospital. On 11 patients of them, therapeutic interventional procedures were made and the results were analysed. 1. In a total of 33 cases, there were 18 cases of upper GI bleeding and 15 cases of lower GI bleeding. The most frequent causes were peptic ulcer in the former and intestinal typhoid fever in the latter. 2. Bleeding sites were localized angiographically in 28 cases, so the detection rate was 85%. Four of the five angiographically negative cases were lower GI bleeding cases. 3. The most frequent bleeding site was left gastric artery (7/33). The next was ileocecal branch of superior mesenteric artery (6/33). 4. Among the 11 interventional procedures, Gelfoam embolization was done in 7 cases and Vasopressin infusion was tried in 4 cases. They were successful in 4 and 3 cases, suggesting 57% and 47% success rates respectively.

  3. Angiographic diagnosis and treatment of gastrointestinal bleeding

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jae Hyung; Sung, Kyu Bo; Koo, Kyung Hoi; Bae, Tae Young; Chung, Eun Chul; Han, Man Chung [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1986-02-15

    Diagnostic angiographic evaluations were done in 33 patients with gastrointestinal bleeding for recent 5 years at Department of Radiology, Seoul National University Hospital. On 11 patients of them, therapeutic interventional procedures were made and the results were analysed. 1. In a total of 33 cases, there were 18 cases of upper GI bleeding and 15 cases of lower GI bleeding. The most frequent causes were peptic ulcer in the former and intestinal typhoid fever in the latter. 2. Bleeding sites were localized angiographically in 28 cases, so the detection rate was 85%. Four of the five angiographically negative cases were lower GI bleeding cases. 3. The most frequent bleeding site was left gastric artery (7/33). The next was ileocecal branch of superior mesenteric artery (6/33). 4. Among the 11 interventional procedures, Gelfoam embolization was done in 7 cases and Vasopressin infusion was tried in 4 cases. They were successful in 4 and 3 cases, suggesting 57% and 47% success rates respectively.

  4. Clinical application of transnasal feeding tube placement under fluoroscopic guidance

    International Nuclear Information System (INIS)

    Ge Kunyuan; Ni Caifang; Liu Yizhi; Zhu Xiaoli; Zou Jianwei; Jin Yonghai; Chen Long; Sun Ge; Sun Lingfang; Zhang Dong

    2008-01-01

    Objective: To evaluate the feasibility and effectiveness of duodenal feeding tube placement under fluoroscopic guidance and its clinical application. Methods: The transnasal duodenal nutriment tubes placement under fluoroscopic guidance were performed in 59 patients from June 3th, 2003 to August 17th, 2007. The successful placement of the feeding tube was defined as that of the tube tip was fixed at or distal to the duodenojejunal junction. Results: 57 out of 59 patients were successfully managed by feeding tube placement, with primary successful rate of 96.6% (57/59). The remaining two failures were due to overdistention of the stomach and were further managed after gastrointestinal decompression thoroughly. The mean fluoroscopy time of the procedure was 17.8 minutes with no severe immediate or delayed complications. Conclusion: The transnasal duodenal nutrient feeding tube placement under fluoroscopic guidance is a safe,economic, and effective management for enteral nutrition, providing extensive clinical utilization. (authors)

  5. A Polymorphic Antioxidant Response Element Links NRF2/sMAF Binding to Enhanced MAPT Expression and Reduced Risk of Parkinsonian Disorders

    Directory of Open Access Journals (Sweden)

    Xuting Wang

    2016-04-01

    Full Text Available The NRF2/sMAF protein complex regulates the oxidative stress response by occupying cis-acting enhancers containing an antioxidant response element (ARE. Integrating genome-wide maps of NRF2/sMAF occupancy with disease-susceptibility loci, we discovered eight polymorphic AREs linked to 14 highly ranked disease-risk SNPs in individuals of European ancestry. Among these SNPs was rs242561, located within a regulatory region of the MAPT gene (encoding microtubule-associated protein Tau. It was consistently occupied by NRF2/sMAF in multiple experiments and its strong-binding allele associated with higher mRNA levels in cell lines and human brain tissue. Induction of MAPT transcription by NRF2 was confirmed using a human neuroblastoma cell line and a Nrf2-deficient mouse model. Most importantly, rs242561 displayed complete linkage disequilibrium with a highly protective allele identified in multiple GWASs of progressive supranuclear palsy, Parkinson’s disease, and corticobasal degeneration. These observations suggest a potential role for NRF2/sMAF in tauopathies and a possible role for NRF2 pathway activators in disease prevention.

  6. Reducing radiation exposure in an electrophysiology lab with introduction of newer fluoroscopic technology

    Directory of Open Access Journals (Sweden)

    Munish Sharma

    2017-09-01

    Full Text Available The use of fluoroscopic devices exposes patients and operators to harmful effects of ionizing radiation in an electrophysiology (EP lab. We sought to know if the newer fluoroscopic technology (Allura Clarity installed in a hybrid EP helps to reduce prescribed radiation dose. We performed radiation dose analysis of 90 patients who underwent various procedures in the EP lab at a community teaching hospital after the introduction of newer fluoroscopic technology in June of 2016.Watchman device insertion, radiofrequency ablation procedures, permanent pacemaker (PPM/implantable cardioverter defibrillator (ICD placement and battery changes were included in the study to compare radiation exposure during different procedures performed commonly in an EP lab. In all cases of watchman device placement, radiofrequency ablation procedures, PPM/ICD placement and battery changes, there was a statistically significant difference (<0.05 in radiation dose exposure. Significant reduction in radiation exposure during various procedures performed in an EP lab was achieved with aid of newer fluoroscopic technology and better image detection technology.

  7. Coronary angiographic characteristics that influence fractional flow reserve.

    Science.gov (United States)

    Natsumeda, Makoto; Nakazawa, Gaku; Murakami, Tsutomu; Torii, Sho; Ijichi, Takeshi; Ohno, Yohei; Masuda, Naoki; Shinozaki, Norihiko; Ogata, Nobuhiko; Yoshimachi, Fuminobu; Ikari, Yuji

    2015-01-01

    Percutaneous coronary intervention (PCI) guided with fractional flow reserve (FFR) has been shown to improve clinical outcome. Although coronary angiography is the standard method for PCI guidance, the visual severity of stenosis is not always correlated with functional severity, suggesting that there are additional angiographic factors that affect functional ischemia. To evaluate angiographic predictors of positive FFR in stenotic lesions, angiographic characteristics of 260 consecutive patients (362 lesions) who underwent FFR testing from April 2009 to September 2012 were analyzed. A scoring system (STABLED score) using these predictors was developed and compared with quantitative coronary angiography (QCA). %Diameter stenosis >50% (OR, 8.43; P20 mm (OR, 5.40; P=0.0002), and distance from ostium <20 mm (OR, 1.94; P=0.028) were determined as independent predictors of positive FFR. Area under the ROC curve for probability of positive FFR using the STABLED score (Stenosis 2 points, TAndem lesion 1 point, Bifurcation 1 point, LEsion length 1 point, Distance from ostium 1 point) was 0.85, higher than that for QCA stenosis alone (0.76). STABLED score ≥3 had 72.3% sensitivity and 83.6% specificity for predicting positive FFR, and PPV was 76.7%. Specific angiographic features are applicable for predicting functional ischemia. STABLED score correlates well with FFR.

  8. New Jersey's Thomas Edison and the fluoroscope.

    Science.gov (United States)

    Tselos, G D

    1995-11-01

    Thomas Edison played a major role in the development of early x-ray technology in 1896, notably increasing tube power and reliability and making the fluoroscope a practical instrument. Eventually, Edison would move x-ray technology from the laboratory to the marketplace.

  9. On the MAF solution of the uniformly lengthening pendulum via change of independent variable in the Bessel’s equation

    Directory of Open Access Journals (Sweden)

    Coşkun Deniz

    Full Text Available Common recipe for the Lengthening Pendulum (LP involves some change of variables to give a relationship with the Bessel’s equation. In this work, semiclassical MAF (Modified Airy Function solution of the LP is being obtained by first transforming the related Bessel’s equation into the normal form via the suggested change of independent variable just as one of our recent work regarding the JWKB solution of the LP in (Deniz, 2017. MAF approximation of the first order Bessel Functions (ν = 1 of both type along with their zeros are being obtained analytically with a very good accuracy as a result of the appropriately chosen associated initial values and they are extended to the neighbouring orders (ν = 0 and 2 by the recursion relations. Although common numerical methods given in the literature require adiabatic LP systems where the lengthening rate is small, MAF solution presented here can safely be used for higher lengthening rates and a criterion for its validity is determined via the use of MAF applicability criterion given in the literature. As a result, the semiclassical MAF method which is normally used for the quantum mechanical and optical waveguide systems is applied to the classical LP system successfully just as our previous work regarding the JWKB solution of the LP. Interestingly, we have very accurate results in the entire domain except for x≈0. PACS: 02.30.Hq, 02.30.Mv, 03.65.Sq, 03.65.-w, 45.05.+x, 45.10.-b, Keywords: Method of Modified Airy Function (MAF, Semiclassical approximation, Linear differential equations, Initial value problems, The lengthening pendulum

  10. mTORC1 directly phosphorylates and regulates human MAF1.

    OpenAIRE

    Michels Annemieke A; Robitaille Aaron M; Buczynski-Ruchonnet Diane; Hodroj Wassim; Reina Jaime H; Hall Michael N; Hernandez Nouria

    2010-01-01

    mTORC1 is a central regulator of growth in response to nutrient availability, but few direct targets have been identified. RNA polymerase (pol) III produces a number of essential RNA molecules involved in protein synthesis, RNA maturation, and other processes. Its activity is highly regulated, and deregulation can lead to cell transformation. The human phosphoprotein MAF1 becomes dephosphorylated and represses pol III transcription after various stresses, but neither the significance of the p...

  11. Percutaneous interventional forceps removal of radiopaque foreign bodies in soft-tissue under fluoroscopic guidance

    International Nuclear Information System (INIS)

    Yang Xiujun; Xing Guangfu; Shi Changwen; Li Wei

    2011-01-01

    fluoroscopic guidance is an effective and micro-invasive method for the removal of radiopaque foreign bodies within soft-tissue. But the technique is contraindicated when the foreign body is close to a big vessel or when a traumatic pseudoaneurysm is accompanied. In complicated cases, preoperative enhanced CT scanning with three-dimensional reconstructed images are essentially required. In this study the concept of vascular and non-vascular foreign body removal under real time X-ray fluoroscopic guidance, i.e. dual interventional techniques, is first proposed by the authors. (authors)

  12. Radiation exposure from shoe-fitting fluoroscopes

    International Nuclear Information System (INIS)

    Busch, Uwe

    2015-01-01

    It is 40 years ago that a very popular X-ray device disappeared in German shoe shops: the shoe-fitting fluoroscope or Pedoskop. Since the 1930s, these X-ray machines were an integral part of any good shoe business. Following the entry into force X-Ray Regulation (RoeV 1973) the use of these devices was prohibited in Germany.

  13. Technique of Peritoneal Catheter Placement under Fluoroscopic Guidance

    International Nuclear Information System (INIS)

    Abdel-Aal, A.K.; Gaddikeri, S.; Saddekni, S.

    2011-01-01

    Peritoneal catheters are mainly used for peritoneal dialysis in patients with end-stage renal disease. Other uses of this catheter include intraperitoneal chemotherapy and gene therapy for ovarian cancer and draining of uncontrolled refractory ascites in patients with liver cirrhosis. Traditionally, surgeons place most of these peritoneal catheters either by laparoscopy or open laparotomy. We detail our percutaneous approach to placing peritoneal catheters using fluoroscopic guidance. We emphasize the use of additional ultrasound guidance, including gray scale and color Doppler ultrasound, to determine the safest puncture site and to guide the initial needle puncture in order to avoid bowel perforation and injury to epigastric artery. We present our experience in placing peritoneal catheters using this technique in 95 patients with various indications. Fluoroscopic guided percutaneous placement of peritoneal catheters is a safe, minimally invasive, and effective alternative to open surgical or laparoscopic placement.

  14. The selective angiographic diagnosis and endovascular embolization treatment of severe epistaxis

    International Nuclear Information System (INIS)

    Zhang Xiquan; Lu Yonghong; Sun Jinghua; Guo Deqiang; Li Yuzhen; Wei Aihua

    2002-01-01

    Objective: To evaluate selective angiographic diagnosis and embolization of severe epistaxis in 57 cases. Methods: 41 cases with spontaneous haemorrhage, 11 cases with traumatic haemorrhage, 3 cases with haemorrhage of nasopharyngeal fibroangioma, and 2 case with haemorrhage of nasopharyngeal carcinoma were included in the study. Selective angiographic diagnosis and embolization of epistaxis were performed with absorbable gelatin sponge or balloon or spring coil by using Seldinger's method. Results: 59 procedure of angiographic diagnosis and embolization were performed in 57 cases. Both maxillaris internal artery embolization was performed in 6 cases. After embolization, satisfactory results were achieved immediately in 55 cases. After 6 months to 2 years' follow-up, no haemorrhage recurred. In 4 cases with traumatic haemorrhage in the face, simple maxillaris internal artery embolization was performed in 2 cases. Conclusion: Selective angiographic diagnosis and embolization are safe, effective, and successful method of choices in the treatment of severe epistaxis

  15. Fluoroscopic screen which is optically homogeneous

    International Nuclear Information System (INIS)

    1975-01-01

    A high efficiency fluoroscopic screen for X-ray examination consists of an optically homogeneous crystal plate of fluorescent material such as activated cesium iodide, supported on a transparent protective plate, with the edges of the assembly beveled and optically coupled to a light absorbing compound. The product is dressed to the desired thickness and provided with an X-ray-transparent light-opaque cover. (Auth.)

  16. Fluoroscopic guidance for placing a double lumen endotracheal tube in adults.

    Science.gov (United States)

    Calenda, Emile; Baste, Jean Marc; Hajjej, Ridha; Rezig, Najiba; Moriceau, Jerome; Diallo, Yaya; Sghaeir, Slim; Danielou, Eric; Peillon, Christophe

    2014-09-01

    The aim of this study was to assess the right placement of the double lumen endotracheal tube with fluoroscopic guidance, which is used in first intention prior to the fiberscope in our institution. This was a prospective observational study. The study was conducted in vascular and thoracic operating rooms. We enrolled 205 patients scheduled for thoracic surgery, with ASA physical statuses of I (n = 37), II (n = 84), III (n = 80), and IV (n = 4). Thoracic procedures were biopsy (n = 20), wedge (n = 34), culminectomy (n = 6), lobectomy (n = 82), pneumonectomy (n = 4), sympathectomy (n = 9), symphysis (n = 47), and thymectomy (n = 3). The intubation with a double lumen tube was performed with the help of a laryngoscope. Tracheal and bronchial balloons were inflated and auscultation was performed after right and left exclusions. One shot was performed to locate the position of the bronchial tube and the hook. Fluoroscopic guidance was used to relocate the tube in case of a wrong position. When the fluoroscopic guidance failed to position the tube, a fiberscope was used. Perioperative collapse of the lung was assessed by the surgeon during the surgery. Correct fluoroscopic image was obtained after the first attempt in 58.5% of patients therefore a misplaced position was encountered in 41.5%. The fluoroscopic guidance allowed an exact repositioning in 99.5% of cases, and the mean duration of the procedure was 8 minutes. A fiberscope was required to move the hook for one patient. We did not notice a moving of the double lumen endotracheal tube during the surgery. The surgeon satisfaction was 100%. The fluoroscopy evidenced the right position of the double lumen tube and allowed a right repositioning in 99.5% of patients with a very simple implementation. Copyright © 2014. Published by Elsevier B.V.

  17. A comparison of chemoembolization endpoints using angiographic versus transcatheter intraarterial perfusion/MR imaging monitoring.

    Science.gov (United States)

    Lewandowski, Robert J; Wang, Dingxin; Gehl, James; Atassi, Bassel; Ryu, Robert K; Sato, Kent; Nemcek, Albert A; Miller, Frank H; Mulcahy, Mary F; Kulik, Laura; Larson, Andrew C; Salem, Riad; Omary, Reed A

    2007-10-01

    Transcatheter arterial chemoembolization (TACE) is an established treatment for unresectable liver cancer. This study was conducted to test the hypothesis that angiographic endpoints during TACE are measurable and reproducible by comparing subjective angiographic versus objective magnetic resonance (MR) endpoints of TACE. The study included 12 consecutive patients who presented for TACE for surgically unresectable HCC or progressive hepatic metastases despite chemotherapy. All procedures were performed with a dedicated imaging system. Angiographic series before and after TACE were reviewed independently by three board-certified interventional radiologists. A subjective angiographic chemoembolization endpoint (SACE) classification scheme, modified from an established angiographic grading system in the cardiology literature, was designed to assist in reproducibly classifying angiographic endpoints. Reproducibility in SACE classification level was compared among operators, and MR imaging perfusion reduction was compared with SACE levels for each observer. Twelve patients successfully underwent 15 separate TACE sessions. SACE levels ranged from I through IV. There was moderate agreement in SACE classification (kappa = 0.46 +/- 0.12). There was no correlation between SACE level and MR perfusion reduction (r = 0.16 for one operator and 0.02 for the other two). Angiographic endpoints during TACE vary widely, have moderate reproducibility among operators, and do not correlate with functional MR imaging perfusion endpoints. Future research should aim to determine ideal angiographic and functional MR imaging endpoints for TACE according to outcome measures such as imaging response, pathologic response, and survival.

  18. 3D fluoroscopic image estimation using patient-specific 4DCBCT-based motion models

    International Nuclear Information System (INIS)

    Dhou, S; Hurwitz, M; Cai, W; Rottmann, J; Williams, C; Wagar, M; Berbeco, R; Lewis, J H; Mishra, P; Li, R; Ionascu, D

    2015-01-01

    3D fluoroscopic images represent volumetric patient anatomy during treatment with high spatial and temporal resolution. 3D fluoroscopic images estimated using motion models built using 4DCT images, taken days or weeks prior to treatment, do not reliably represent patient anatomy during treatment. In this study we developed and performed initial evaluation of techniques to develop patient-specific motion models from 4D cone-beam CT (4DCBCT) images, taken immediately before treatment, and used these models to estimate 3D fluoroscopic images based on 2D kV projections captured during treatment. We evaluate the accuracy of 3D fluoroscopic images by comparison to ground truth digital and physical phantom images. The performance of 4DCBCT-based and 4DCT-based motion models are compared in simulated clinical situations representing tumor baseline shift or initial patient positioning errors. The results of this study demonstrate the ability for 4DCBCT imaging to generate motion models that can account for changes that cannot be accounted for with 4DCT-based motion models. When simulating tumor baseline shift and patient positioning errors of up to 5 mm, the average tumor localization error and the 95th percentile error in six datasets were 1.20 and 2.2 mm, respectively, for 4DCBCT-based motion models. 4DCT-based motion models applied to the same six datasets resulted in average tumor localization error and the 95th percentile error of 4.18 and 5.4 mm, respectively. Analysis of voxel-wise intensity differences was also conducted for all experiments. In summary, this study demonstrates the feasibility of 4DCBCT-based 3D fluoroscopic image generation in digital and physical phantoms and shows the potential advantage of 4DCBCT-based 3D fluoroscopic image estimation when there are changes in anatomy between the time of 4DCT imaging and the time of treatment delivery. (paper)

  19. Angiographic findings of hepatocellular carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Han, Man Chung; Cho, Byung Jae; Huh, Seung Jae; Bae, Sang Hoon; Kim, Ung Jin; Kim, Chung Yong; Kim, Noe Kyeong [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1985-12-15

    From March 1977 to July 1979, 69 cases of angiograms of hepatocellular carcinoma were observed in Seoul National University Hospital. The findings of selective celiac and/or hepatic arteriography in total 69 cases of confirmed hepatocellular carcinoma, with clinical and laboratory findings, were analyzed. The summarized results are as follows; 1. Among 69 cases od hepatoma, 62 were male and 7 were female with sex ratio of 8.9 : 1. Peak incidence is 5th to 7th decades (72.5%). Epigastric pain, indigestion, and palpable mass in right upper quadrant were common symptoms and sign. Laboratory findings showed elevated serum alkaline phosphatase more than 5 Bodansky unit in 75.4%. Alpha-feto protein was positive in 65.2% of all the patients. 2 All 69 cases were classified into 31 cases of massive type, 22 cases of diffuse type, and 16 cases of nodular type, in accordance with angiographic gross anatomy. The frequency of angiographic findings were hypervascularities and tumor vessels (100%), tumor stainings (98.5%), arteriovenous shunt (71.0%), displacement of intrahepatic arteries (66.7%), vascular lakes and channel (59.4%). Encasement of hepatic artery and portal vein regurgitation was respectively 4 cases. Tumor mass in portal vein were 6 cases and tumor mass in hepatic vein was 1 case. 3. Intraarterial infusion of 5-FU was performed in 15 hepatoma patients, and the results were that angiographic improvement was demonstrated in 3 cases, no improvement in 8 cases, and incomplete infusion in 4 cases. 4. The selective celiac and/or hepatic angiograms are excellent diagnostic tools as well as therapeutic management for intraarterial infusion of anticancerous drugs.

  20. Angiographic findings of hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Han, Man Chung; Cho, Byung Jae; Huh, Seung Jae; Bae, Sang Hoon; Kim, Ung Jin; Kim, Chung Yong; Kim, Noe Kyeong

    1985-01-01

    From March 1977 to July 1979, 69 cases of angiograms of hepatocellular carcinoma were observed in Seoul National University Hospital. The findings of selective celiac and/or hepatic arteriography in total 69 cases of confirmed hepatocellular carcinoma, with clinical and laboratory findings, were analyzed. The summarized results are as follows; 1. Among 69 cases od hepatoma, 62 were male and 7 were female with sex ratio of 8.9 : 1. Peak incidence is 5th to 7th decades (72.5%). Epigastric pain, indigestion, and palpable mass in right upper quadrant were common symptoms and sign. Laboratory findings showed elevated serum alkaline phosphatase more than 5 Bodansky unit in 75.4%. Alpha-feto protein was positive in 65.2% of all the patients. 2 All 69 cases were classified into 31 cases of massive type, 22 cases of diffuse type, and 16 cases of nodular type, in accordance with angiographic gross anatomy. The frequency of angiographic findings were hypervascularities and tumor vessels (100%), tumor stainings (98.5%), arteriovenous shunt (71.0%), displacement of intrahepatic arteries (66.7%), vascular lakes and channel (59.4%). Encasement of hepatic artery and portal vein regurgitation was respectively 4 cases. Tumor mass in portal vein were 6 cases and tumor mass in hepatic vein was 1 case. 3. Intraarterial infusion of 5-FU was performed in 15 hepatoma patients, and the results were that angiographic improvement was demonstrated in 3 cases, no improvement in 8 cases, and incomplete infusion in 4 cases. 4. The selective celiac and/or hepatic angiograms are excellent diagnostic tools as well as therapeutic management for intraarterial infusion of anticancerous drugs.

  1. A combined approach based on MAF analysis and AHP method to fault detection mapping: A case study from a gas field, southwest of Iran

    Science.gov (United States)

    Shakiba, Sima; Asghari, Omid; Khah, Nasser Keshavarz Faraj

    2018-01-01

    A combined geostatitical methodology based on Min/Max Auto-correlation Factor (MAF) analysis and Analytical Hierarchy Process (AHP) is presented to generate a suitable Fault Detection Map (FDM) through seismic attributes. Five seismic attributes derived from a 2D time slice obtained from data related to a gas field located in southwest of Iran are used including instantaneous amplitude, similarity, energy, frequency, and Fault Enhancement Filter (FEF). The MAF analysis is implemented to reduce dimension of input variables, and then AHP method is applied on three obtained de-correlated MAF factors as evidential layer. Three Decision Makers (DMs) are used to construct PCMs for determining weights of selected evidential layer. Finally, weights obtained by AHP were multiplied in normalized valued of each alternative (MAF layers) and the concluded weighted layers were integrated in order to prepare final FDM. Results proved that applying algorithm proposed in this study generate a map more acceptable than the each individual attribute and sharpen the non-surface discontinuities as well as enhancing continuity of detected faults.

  2. Edge enhancement algorithm for low-dose X-ray fluoroscopic imaging.

    Science.gov (United States)

    Lee, Min Seok; Park, Chul Hee; Kang, Moon Gi

    2017-12-01

    Low-dose X-ray fluoroscopy has continually evolved to reduce radiation risk to patients during clinical diagnosis and surgery. However, the reduction in dose exposure causes quality degradation of the acquired images. In general, an X-ray device has a time-average pre-processor to remove the generated quantum noise. However, this pre-processor causes blurring and artifacts within the moving edge regions, and noise remains in the image. During high-pass filtering (HPF) to enhance edge detail, this noise in the image is amplified. In this study, a 2D edge enhancement algorithm comprising region adaptive HPF with the transient improvement (TI) method, as well as artifacts and noise reduction (ANR), was developed for degraded X-ray fluoroscopic images. The proposed method was applied in a static scene pre-processed by a low-dose X-ray fluoroscopy device. First, the sharpness of the X-ray image was improved using region adaptive HPF with the TI method, which facilitates sharpening of edge details without overshoot problems. Then, an ANR filter that uses an edge directional kernel was developed to remove the artifacts and noise that can occur during sharpening, while preserving edge details. The quantitative and qualitative results obtained by applying the developed method to low-dose X-ray fluoroscopic images and visually and numerically comparing the final images with images improved using conventional edge enhancement techniques indicate that the proposed method outperforms existing edge enhancement methods in terms of objective criteria and subjective visual perception of the actual X-ray fluoroscopic image. The developed edge enhancement algorithm performed well when applied to actual low-dose X-ray fluoroscopic images, not only by improving the sharpness, but also by removing artifacts and noise, including overshoot. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Clinical application of percutaneous gastrostomy and gastrojejunostomy under fluoroscopic guidance

    International Nuclear Information System (INIS)

    Zhou Jianping; Wang Zhongmin; Liu Tao; Chen Kemin; Gong Ju; Zheng Yunfeng; Chen Zhijin; Shen Jieyun

    2011-01-01

    Objective: To evaluate the safety and effectiveness of percutaneous gastrostomy (PRG) and gastrojejunostomy (PRGJ) under fluoroscopic guidance, and to discuss its technical manipulation, the indications and contraindications as well as the complications. Methods: During the period from May 2002 to June 2010 in authors' hospital fluoroscopically-guided PRG or PRGJ was carried out in 40 patients. The clinical data were retrospectively analyzed. With Seldinger technique and under fluoroscopic guidance, a 14 F radiopaque gastrostomy or gastrojejunostomy feeding catheter was successfully placed. The indications, operation procedures, clinical success rate, procedure-related complications, and tube indwelling time, etc. were discussed and analyzed. Results: PRG was conducted in 30 patients. The reasons for performing PRG included neurologic disease (n=13), recurrent aspiration pneumonia (n=6), gastroesophageal reflux due to disfunction of gastrointestinal tract (n=3), subtotal gastrectomy (n=2), esophagomediastinal fistula (n=1) and esophageal carcinoma (n=5). PRGJ was carried out in 10 patients. The disorders included bulbar paralysis (n=3), malignant duodenal obstruction (n=4) and previous gastrostomy-related complications (n=3). Two anchors were used in all patients receiving PRG or PRGJ. Clinical success was achieved in all study patients. No procedure-related or severe complications occurred. Minor complications were observed in four patients (10%), which included local soft tissue infection (n=1), severe puncture site pain (n=1), gastrostomy tube dislodgement (n=1) and obstruction of gastrojejunostomy tube (n=1). During the follow-up period, no aggravation of gastroesophageal reflux or aspiration pneumonia was observed in all patients. The tube indwelling time was 115 to 585 days (mean of 150 days) after tube placement. Conclusion: Fluoroscopically-guided percutaneous gastrostomy or gastrojejunostomy is a safe, simple and minimally-invasive technique. This

  4. Accessory left gastric artery: angiographic anatomy

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kang Soo; Lim, Hyung Guhn; Kim, Hong Soo; Jeon, Doo Sung [Presbyterian Medical Center, Chunju (Korea, Republic of); Chung, Jin Wook; Park, Jae Hyung [College of Medicine and the Institute of Radiation Medicine, Seoul National University, Seoul (Korea, Republic of); Song, Soon Young [Myongji Hospital, College of Medicine, Kwandong University, Seoul (Korea, Republic of)

    2000-09-01

    To evaluate the angiographic anatomy of the accessory left gastric artery (accLGA). We evaluated the angiographic findings of the accLGA in 50 patients (Angiostar; Siemens, Erlangen, Germany). Performing celiac and selective angiography in 50 and 34 patients, respectively. By means of celiac angiography, (1) site of origin, (2) anatomical course, (3) diameter, (4) degree of tortuosity, and (5) distal tapering were evaluated, while selective angiography was used to determine (1) arterial branching, (2) area of blood supply, and (3) patterns of gastric wall stain. Celiac angiography showed that the accLGA arose from the left hepatic artery (LHA) in 45 cases (90%) and from the proper hepatic artery in five (10%). If the accLGA arose from the LHA, its origin entirely depended on the branching pattern of the latter. It always arose from the lateral branch of the LHA furthest to the left and uppermost, and proximal to its umbilical point. The most common anatomical course of the accLGA, seen in 27 cases (54%), was between the S2 and S3 segmental branch. The diameter and degree of tortuosity of the accLGA were similar to those of adjacent intrahepatic branches in 21 (42%) and 33 cases (66%), respectively. The degree of tapering was less than that of adjacent intrahepatic vessel in 28 (56%). Selective angiography demonstrated esophageal branching of the acc LGA in 27 cases (79%), inferior phrenic arterial branching in three (9%), a mediastinal branch in one (3%), and hypervascularity of the lung in one (3%). In 15 cases (44%), bifurcation of the accLGA was recognized. The vascular territory of the accLGA was the gastric fundus together with the distal esophagus in 21 cases (62%), mainly the gastric fundus in six (18%), and mainly the distal esophagus in four (12%). The pattern of gastric mucosal stain was curvilinear wall in 31 cases (91%) and nodular in three (9%). A knowledge of the angiographic anatomy of the accLGA facilitates accurate recognition of this artery on

  5. A simple digital subtraction angiographic instrument

    International Nuclear Information System (INIS)

    Ando, Hiroshi; Kobayashi, Tsuyoshi; Imai, Yutaka; Yanagishita, Akira

    1983-01-01

    A digital subtraction angiographic instrument was manufactured using a conventional x-ray TV for gastrointestinal series and a computer for processing of nuclear medical data. The results of visualization of the aorta and its primary branches were reviewed with demonstrable cases. (Chiba, N.)

  6. Effect of transcatheter arterial embolization according to angiographic findings in hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Wang, Chi Hyung; Shim, Hyung Jin; Lee, Jong Ik; Yu, Hyun; Kim, Young Goo; Lee, Jong Beum; Kim, Kun Sang

    1994-01-01

    The purpose of this study is to assess the effect of Transcatheter Arterial Embolization(TAE) according to angiographic findings in hepatocellular carcinoma. We retrospectively reviewed 50 cases who received TAE for unresectable hepatocellular carcinoma. We analyzed the angiographic findings which were correlated with the effect of TAE. The common angiographic findings of the hepatocellular carcinoma were tumor staining, neo vascularity and enlargement of feeding artery. These angiographic findings were classified into grade 0, +1, +2. Effect of TAE were classified into five patterns; good response, partial response, minimal response, no response and more aggravation. In grading of tumor staining, among 50 cases, the grade 0, +1, +2 were seen in 1 case(2%), 14 cases(28%), 35 cases(70%) each. In grading of enlargement of feeding artery, the grade 0, +1, +2 were seen in 7 cases(14%), 19 cases(38%), 24 cases(48%) each. In grading of neo vascularity, the grade 0, +1, +2 were seen in 6 cases(12%), 15 cases(30%), 29 cases(58%) each. This study showed that the higher grade of angiographic finding, the better effect of TAE. A statistically significant difference was found (P<0.005). But the TAE was not effective in some cases (the maximum diameter of mass is over 10cm, portal vein thrombosis or arteriovenous shunt) in spite of high grade. We believe that these angiographic findings (tumor staining, enlargement of feeding artery, neo vascularity) are one of important indices for anticipating the effect of TAE in patients with unresectable hepatocellular carcinoma

  7. Promising role for Gc-MAF in cancer immunotherapy: from bench to bedside

    OpenAIRE

    Saburi, Ehsan; Saburi, Amin; Ghanei, Mostafa

    2017-01-01

    Immunotherapy has been used for years in many types of cancer therapy. Recently, cancer immunotherapy has focused on mechanisms which can enhance the development of cell-mediated immunity. Anticancer medications are administered to inhibit immunosuppressive factors such as nagalase enzyme, which is produced by neoplastic cells and destroys macrophage activating factor (Gc-MAF). Anti-neoplastics medications can also enhance immune-cell activity against tumors. Such medications show great poten...

  8. Patient dose measurements in fluoroscopic examinations, aiming to the establishment of reference levels in Brazil

    International Nuclear Information System (INIS)

    Canevaro, L.; Drexler, G.

    2001-01-01

    This work was performed to investigate the actual exposure levels of the patients submitted to fluoroscopic procedures in diagnostic radiology. The data will be useful for a baseline in the establishment of local reference levels for fluoroscopic procedures, as recommended by the European Commission and IAEA. At present time there are no internationally accepted definitions for references levels for fluoroscopic complex procedures. Dose-area product (DAP) meters were employed in a pilot survey expressing the radiation exposures in terms of this quantity. This class of instrumentation has not yet been employed in Brazil. Parameters recorded were radiographic technique, fluoroscopy time, number of images, fluoroscopic and radiographic field sizes and DAPs. For fluoroscopy practice, a reference parameters set is recommended, instead of one diagnostic reference level. High patient exposures were found, calling for joined actions of health authorities, physicians, medical physicists, technicians and manufacturers. Monitoring of patient exposure, optimizing the radiation protection and establishing quantitative assessments of the exposition to the population in Brazil in this kind of procedure is important. (author)

  9. Cryo-balloon catheter localization in fluoroscopic images

    Science.gov (United States)

    Kurzendorfer, Tanja; Brost, Alexander; Jakob, Carolin; Mewes, Philip W.; Bourier, Felix; Koch, Martin; Kurzidim, Klaus; Hornegger, Joachim; Strobel, Norbert

    2013-03-01

    Minimally invasive catheter ablation has become the preferred treatment option for atrial fibrillation. Although the standard ablation procedure involves ablation points set by radio-frequency catheters, cryo-balloon catheters have even been reported to be more advantageous in certain cases. As electro-anatomical mapping systems do not support cryo-balloon ablation procedures, X-ray guidance is needed. However, current methods to provide support for cryo-balloon catheters in fluoroscopically guided ablation procedures rely heavily on manual user interaction. To improve this, we propose a first method for automatic cryo-balloon catheter localization in fluoroscopic images based on a blob detection algorithm. Our method is evaluated on 24 clinical images from 17 patients. The method successfully detected the cryoballoon in 22 out of 24 images, yielding a success rate of 91.6 %. The successful localization achieved an accuracy of 1.00 mm +/- 0.44 mm. Even though our methods currently fails in 8.4 % of the images available, it still offers a significant improvement over manual methods. Furthermore, detecting a landmark point along the cryo-balloon catheter can be a very important step for additional post-processing operations.

  10. CT, MR and angiographic findings of hemangiopericytomas

    International Nuclear Information System (INIS)

    Lim, Soo Mee; Lee, Ho Kyu; Shin, Ji Hoon; Kim, Jae Kyun; Kim, Dae Hong; Choi, Choong Gon; Suh, Dae Chul

    1999-01-01

    Hemangiopericytoma(HP) exhibits its pathologic findings different from those of meningioma or other angiomatous tumor; and its clinical behavior is unique and prognosis worse than other cases. We reviewed the CT, MR and angiographic findings of HPs and evaluated differential radiologic points of comparison between typical meningiomas and meningeal HPs. MR(n=16), CT(n=5) and angiographic imaging(n=10) were performed in 18 patients(M:F = 12:6, mean age: 45 years) with histologically proven primary HPs. We evaluated the imaging findings of HPs with respect to site, shape, size, signal intensity, enhancement characteristics, vascular signal voids, calcification, bony and adjacent sinus involvement, and angiographic findings. HPs were meningeal in 14 cases and nonmeningeal in four. Meningeal HPs were located in the parasagittal region(n=8), convexity(n=3), intradural extramedullary space(n=1), choroid plexus(n=1), and olfactory groove(n=1). Nonmeningeal HPs were located in the masticator space(n=2), paraspinal area(n=1) and supraclavicular area(n=1). The mean maximal dimension of tumors was about 5.4cm and their shape was papillary(n=8) or lobulated(n=7). MR images showed high(n=13) or iso(n=3) signal intensities on T2W1, and heterogeneity on T2W1(n=9). Vascular signal voids in the mass were seen in all cases, while in two cases, CT scanning showed nodular dense calcification. Bone destruction was present in six cases, but no hyperostosis was found. In five cases, the superior sagittal sinus was involved. Angiographic images revealed highly vascular masses supplied by the internal carotid artery(n=5), external carotid artery(n=8), descending scapular artery(n=1) and radiculomedullary artery(n=1), with delayed tumor blush during the capillary and venous phase in which there was no arteriovenous shunt. HP is one of the extra-axial tumors in which there is hypervascularity, aggressive bony destruction arising in the meningeal and extrameningeal area, and heterogeneous high

  11. Radiofrequency catheter ablation: Relationship between fluoroscopic time and skin doses according to diagnoses. Basis to establish a quality assurance programme

    International Nuclear Information System (INIS)

    Cotelo, E.; Pouso, J.; Reyes, W.

    2001-01-01

    Radiofrequency Cardiac Catheter Ablation is an Interventional Radiology procedure of great complexity because the cardiologist needs a simultaneous evaluation of fluoroscopic images and electrophysiologic information. Therefore, the procedure typically involves extended fluoroscopic time that may cause radiation-skin injures to patients. Skin doses depend on many factors: equipment design features and its proper use, cardiologist practice, fluoroscopic time, irradiated areas, application of radiation protection recommendations, etc. We evaluate fluoroscopic time in relation to pathology and we estimate skin doses on 233 procedures at the Electrophysiology Laboratory in Casa de Galicia, Montevideo, Uruguay. Significant differences among the medians of fluoroscopic time were found in those procedures depending on diagnoses and results. Higher fluoroscopic time was found in flutter and auricular tachycardia (median was 83 minutes, p=0.0001). In successful procedures (almost 90%), median skin doses was 2.0 Grays (p=0.0001). On the basis of records information, the standard operating procedure and the clinical protocol, expanding close cooperation between the cardiologists and the experts in Radiation Protection will secure the establishment of an Assurance Quality Program. (author)

  12. Clinical and angiographic outcomes after intracoronary bare-metal stenting.

    Directory of Open Access Journals (Sweden)

    I-Chang Hsieh

    Full Text Available BACKGROUND: Data from a large patient population regarding very long-term outcomes after BMS implantation are inadequate. This study aimed to evaluate the very long-term (8-17 years clinical and long-term (3-5 years angiographic outcomes after intracoronary bare-metal stenting (BMS. METHODS AND RESULTS: From the Cardiovascular Atherosclerosis and Percutaneous TrAnsluminal INterventions (CAPTAIN registry, a total of 2391 patients with 2966 lesions treated with 3190 BMSs between November 1995 and May 2004 were evaluated. In total, 1898 patients with 2364 lesions, and 699 patients with 861 lesions underwent 6-month and 3- to 5- year angiographic follow-up, respectively. During a mean follow-up period of 149 ± 51 months, 18.6% of the patients died (including 10.8% due to cardiac death, 6.1% developed reinfarction, 16.2% had target lesion revascularization (including 81% of the patients within the first year, 14.5% underwent new lesion stenting (including 72% of the patients after 3 years, 2.4% underwent coronary bypass surgery, and 1.6% had definite stent thrombosis. The overall cardiovascular event-free survival rate was 58.5%. The 6-month angiographic study indicated a 20% restenosis rate. The minimal luminal diameter increased from 0.65 ± 0.44 mm to 3.02 ± 0.46 mm immediately after stenting, decreased to 2.06 ± 0.77 mm at the 6-month follow-up, and increased to 2.27 ± 0.68 mm at the 3- to 5-year follow-up. CONCLUSIONS: This study provides clinical and angiographic results from a large population of patients who underwent BMS implantations after a long-term follow-up period (149 ± 51 months. The progression of coronary atherosclerosis developed over time, and presented with new lesion required stent implantation. The follow-up angiographic findings reconfirmed the late and sustained improvement in luminal diameter between 6 months and 3-5 years.

  13. Management of pediatric radiation dose using GE fluoroscopic equipment

    International Nuclear Information System (INIS)

    Belanger, Barry; Boudry, John

    2006-01-01

    In this article, we present GE Healthcare's design philosophy and implementation of X-ray imaging systems with dose management for pediatric patients, as embodied in its current radiography and fluoroscopy and interventional cardiovascular X-ray product offerings. First, we present a basic framework of image quality and dose in the context of a cost-benefit trade-off, with the development of the concept of imaging dose efficiency. A set of key metrics of image quality and dose efficiency is presented, including X-ray source efficiency, detector quantum efficiency (DQE), detector dynamic range, and temporal response, with an explanation of the clinical relevance of each. Second, we present design methods for automatically selecting optimal X-ray technique parameters (kVp, mA, pulse width, and spectral filtration) in real time for various clinical applications. These methods are based on an optimization scheme where patient skin dose is minimized for a target desired image contrast-to-noise ratio. Operator display of skin dose and Dose-Area Product (DAP) is covered, as well. Third, system controls and predefined protocols available to the operator are explained in the context of dose management and the need to meet varying clinical procedure imaging demands. For example, fluoroscopic dose rate is adjustable over a range of 20:1 to adapt to different procedure requirements. Fourth, we discuss the impact of image processing techniques upon dose minimization. In particular, two such techniques, dynamic range compression through adaptive multiband spectral filtering and fluoroscopic noise reduction, are explored in some detail. Fifth, we review a list of system dose-reduction features, including automatic spectral filtration, virtual collimation, variable-rate pulsed fluoroscopic, grid and no-grid techniques, and fluoroscopic loop replay with store. In addition, we describe a new feature that automatically minimizes the patient-to-detector distance, along with an

  14. Scale-space for empty catheter segmentation in PCI fluoroscopic images.

    Science.gov (United States)

    Bacchuwar, Ketan; Cousty, Jean; Vaillant, Régis; Najman, Laurent

    2017-07-01

    In this article, we present a method for empty guiding catheter segmentation in fluoroscopic X-ray images. The guiding catheter, being a commonly visible landmark, its segmentation is an important and a difficult brick for Percutaneous Coronary Intervention (PCI) procedure modeling. In number of clinical situations, the catheter is empty and appears as a low contrasted structure with two parallel and partially disconnected edges. To segment it, we work on the level-set scale-space of image, the min tree, to extract curve blobs. We then propose a novel structural scale-space, a hierarchy built on these curve blobs. The deep connected component, i.e. the cluster of curve blobs on this hierarchy, that maximizes the likelihood to be an empty catheter is retained as final segmentation. We evaluate the performance of the algorithm on a database of 1250 fluoroscopic images from 6 patients. As a result, we obtain very good qualitative and quantitative segmentation performance, with mean precision and recall of 80.48 and 63.04% respectively. We develop a novel structural scale-space to segment a structured object, the empty catheter, in challenging situations where the information content is very sparse in the images. Fully-automatic empty catheter segmentation in X-ray fluoroscopic images is an important and preliminary step in PCI procedure modeling, as it aids in tagging the arrival and removal location of other interventional tools.

  15. Multislice computed tomography: angiographic emulation versus standard assessment for detection of coronary stenoses

    Energy Technology Data Exchange (ETDEWEB)

    Schnapauff, Dirk; Hamm, Bernd; Dewey, Marc [Humboldt-Universitaet zu Berlin, Department of Radiology, Charite - Universitaetsmedizin Berlin, Chariteplatz 1, P.O. Box 10098, Berlin (Germany); Duebel, Hans-Peter; Baumann, Gert [Charite - Universitaetsmedizin Berlin, Department of Cardiology, Berlin (Germany); Scholze, Juergen [Charite - Universitaetsmedizin Berlin, Charite Outpatient Centre, Berlin (Germany)

    2007-07-15

    The present study investigated angiographic emulation of multislice computed tomography (MSCT) (catheter-like visualization) as an alternative approach of analyzing and visualizing findings in comparison with standard assessment. Thirty patients (120 coronary arteries) were randomly selected from 90 prospectively investigated patients with suspected coronary artery disease who underwent MSCT (16-slice scanner, 0.5 mm collimation, 400 ms rotation time) prior to conventional coronary angiography for comparison of both approaches. Sensitivity and specificity of angiographic emulation [81% (26/32) and 93% (82/88)] were not significantly different from those of standard assessment [88% (28/32) and 99% (87/88)], while the per-case analysis time was significantly shorter for angiographic emulation than for standard assessment (3.4 {+-} 1.5 vs 7.0 {+-} 2.5 min, P < 0.001). Both interventional and referring cardiologists preferred angiographic emulation over standard curved multiplanar reformations of MSCT coronary angiography for illustration, mainly because of improved overall lucidity and depiction of sidebranches (P < 0.001). In conclusion, angiographic emulation of MSCT reduces analysis time, yields a diagnostic accuracy comparable to that of standard assessment, and is preferred by cardiologists for visualization of results. (orig.)

  16. Diagnosis of cardiovascular diseases by digital fluoroscopic angiography

    International Nuclear Information System (INIS)

    Takahashi, Mutsumasa; Hirota, Yoshihisa; Tsuchigame, Naotoshi

    1982-01-01

    Digital fluoroscopic angiography (DFA) is a recently developed angiocardiographic technique, which consists of digitization and real-time subtraction of X-ray transmission data from an image intensifier and television fluoroscopic system. A prototype unit based on this principle was developed and installed at our hospital and initial clinical trial has been performed. Fifty-three examinations were performed on 49 patients with various cardiovascular conditions. DFA was useful in demonstration of intracardiac shunt, and valvular diseases secondary to congenital heart diseases. In ischemic heart diseases, DFA noninvasively demonstrated the heart wall motion, making it possible to evaluate dyskinesis, akinesis and ventricular aneurysm. DFA was also valuable in visualizing disproportionate enlargement of cardiac chambers, stasis, and frequently regurgitation of contrast media in valvular heart diseases. Abnormal mediastinal enlargement and aortic aneurysm were differentiated from other conditions to good advantage. DFA will be used more widely in the above conditions because of non-invasive and simple procedures. Future effort should be directed towards improvement of spatial resolution and development of new algorithm for hemodynamic evaluation. (author)

  17. Fluoroscopic dose reduction by acquisition frame rate reduction and image processing

    International Nuclear Information System (INIS)

    Fritz, S.L.; Mirvis, S.E.; Pals, S.O.

    1986-01-01

    A new design for fluoroscopic exposure reduction incorporates pulsed x-ray exposure, progressive scan video acquisition at frame rates below 30 Hz, interlaced video display at 30 Hz, and a video rate image processing. To evaluate this design, a variety of phantom systems have been developed to measure the impact of low frame rate pulsed digital fluoroscopy on the performance of several clinical tasks (e.g., catheter placement). The authors are currently using these phantoms with a digital fluoroscopy system using continuous x-ray, interlaced video acquisition and variable acquisition frame rate. The design of their target digital fluoroscopic system, sample image sequences, and the results of some preliminary phantom studies are reported

  18. ANGIOGRAPHIC ANATOMY OF THE MAJOR ABDOMINAL ARTERIAL BLOOD SUPPLY IN THE DOG.

    Science.gov (United States)

    Culp, William T N; Mayhew, Philipp D; Pascoe, Peter J; Zwingenberger, Allison

    2015-01-01

    Vascular-based interventional radiology (IR) procedures are being more regularly performed in veterinary patients for both diagnostic and therapeutic purposes. A complete description of the fluoroscopic arterial anatomy of the canine abdominal cavity has not been published. This information is essential for performance of IR procedures to allow for improved preparation before and during a particular procedure. The primary purpose of this study was to provide a fluoroscopic description of the vascular branching from the abdominal aorta in a ventro-dorsal projection with a secondary goal of producing pictorial reference images of the major abdominal arterial blood vessels. Five healthy female hound type dogs were enrolled and underwent fluoroscopic arteriography. During fluoroscopy, both nonselective and selective arteriography were performed. The nonselective arteriograms were obtained in the aorta at four locations: cranial to the celiac artery, cranial to the renal arteries, cranial to the caudal mesenteric artery, and cranial to the branching of the external iliac arteries. Selective arteriography was conducted by performing injections into the following arteries: celiac, splenic, common hepatic, cranial mesenteric, left and right renal, and caudal mesenteric. Fluoroscopic arteriography allowed for excellent characterization of the aortic ostia and the location of the lower order vascular branches. Future evaluation of vascular-based treatment options will likely increase as the understanding of the normal and pathologic anatomy improves. © 2015 American College of Veterinary Radiology.

  19. Mobile Health Technology for Atrial Fibrillation Management Integrating Decision Support, Education, and Patient Involvement: mAF App Trial.

    Science.gov (United States)

    Guo, Yutao; Chen, Yundai; Lane, Deirdre A; Liu, Lihong; Wang, Yutang; Lip, Gregory Y H

    2017-12-01

    Mobile Health technology for the management of patients with atrial fibrillation is unknown. The simple mobile AF (mAF) App was designed to incorporate clinical decision-support tools (CHA 2 DS 2 -VASc [Congestive heart failure, Hypertension, Age ≥75 years, Diabetes Mellitus, Prior Stroke or TIA, Vascular disease, Age 65-74 years, Sex category], HAS-BLED [Hypertension, Abnormal renal/liver function, Stroke, Bleeding history or predisposition, Labile INR, Elderly, Drugs/alcohol concomitantly], SAMe-TT 2 R 2 [Sex, Age Mobile Health technology in patients with atrial fibrillation, demonstrating that the mAF App, integrating clinical decision support, education, and patient-involvement strategies, significantly improved knowledge, drug adherence, quality of life, and anticoagulation satisfaction. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  20. Experiences upgrading a fluoroscopic system to digital specifications

    International Nuclear Information System (INIS)

    Fox, T.; Fenzl, G.

    1995-01-01

    In 1993, an undertable fluoroscopic system was retrofitted with a Fluorospot HC digital system at the radiological clinic of the Knappschaftskrankenhaus in Puettlingen, Germany. The experiences and possibilities resulting from this digital upgrade are related by the authors, whose narrative is also accompanied by examples of clinical images. The costs involved are also discussed in this article. (orig.)

  1. Adjustable radiation protection device of the fluoroscope DG 10

    International Nuclear Information System (INIS)

    Hoermann, D.

    1980-01-01

    In cooperation with the 'VEB Transformatoren- und Roentgenwerk Hermann Matern', Dresden, an adjustable radiation protection device has been developed. This supplementary equipment for fluoroscopes ensures a sufficient protection of the gonads against undesirable X radiation, can be handled easily and does not annoy patients, esp. children

  2. Measurement of erosion of stainless steel by molten lead-free solder using micro-focus x-ray CT system

    International Nuclear Information System (INIS)

    Nishikawa, Hiroshi; Takemoto, Tadashi; Kang, Songai

    2009-01-01

    The severe erosion damage, which is caused by a molten lead-free solder, of wave solder equipment made into stainless steel has been encountered in operation. Then, the higher maintenance frequency and reduced life time of wave solder machine component is a serious issue in a manufacturing process. In this study, the evaluation method of erosion of stainless steel by molten lead-free solders was investigated using micro-focus X-ray systems for fluoroscopic and computed tomography (CT). As a result, it was found that the fluoroscopic image could truly reconstruct the cross-shape of the stainless steel sample after immersion test without destruction. In the case of X-ray systems for fluoroscopic and CT used in this study, three-dimensional data can be obtained. Therefore, it was possible to easily check the whole picture of the test sample after immersion test and to decide the maximum erosion depth of test sample. (author)

  3. Spontaneous regression of cerebral arteriovenous malformations: clinical and angiographic analysis with review of the literature

    International Nuclear Information System (INIS)

    Lee, S.K.; Vilela, P.; Willinsky, R.; TerBrugge, K.G.

    2002-01-01

    Spontaneous regression of cerebral arteriovenous malformation (AVM) is rare and poorly understood. We reviewed the clinical and angiographic findings in patients who had spontaneous regression of cerebral AVMs to determine whether common features were present. The clinical and angiographic findings of four cases from our series and 29 cases from the literature were retrospectively reviewed. The clinical and angiographic features analyzed were: age at diagnosis, initial presentation, venous drainage pattern, number of draining veins, location of the AVM, number of arterial feeders, clinical events during the interval period to thrombosis, and interval period to spontaneous thrombosis. Common clinical and angiographic features of spontaneous regression of cerebral AVMs are: intracranial hemorrhage as an initial presentation, small AVMs, and a single draining vein. Spontaneous regression of cerebral AVMs can not be predicted by clinical or angiographic features, therefore it should not be considered as an option in cerebral AVM management, despite its proven occurrence. (orig.)

  4. SU-D-209-02: Percent Depth Dose Curves for Fluoroscopic X-Ray Beam Qualities Incorporating Copper Filtration

    Energy Technology Data Exchange (ETDEWEB)

    Wunderle, K [Cleveland Clinic Foundation, Cleveland, OH (United States); Wayne State University School of Medicine, Detroit, MI (United States); Godley, A; Shen, Z; Dong, F [Cleveland Clinic Foundation, Cleveland, OH (United States); Rakowski, J [Wayne State University School of Medicine, Detroit, MI (United States)

    2016-06-15

    Purpose: The purpose of this investigation was to quantify percent depth dose (PDD) curves for fluoroscopic x-ray beam qualities incorporating added copper filtration. Methods: A PTW (Freiburg, Germany) MP3 water tank was used with a Standard Imaging (Middleton, WI) Exradin Model 11 Spokas Chamber to measure PDD curves for 60, 80, 100 and 120 kVp x-ray beams with copper filtration ranging from 0.0–0.9 mm at 22cm and 42cm fields of view from 0 to 150 mm of water. A free-in-air monitor chamber was used to normalize the water tank data to fluctuations in output from the fluoroscope. The measurements were acquired on a Siemens (Erlangen, Germany) Artis ZeeGo fluoroscope. The fluoroscope was inverted from the typical orientation providing an x-ray beam originating from above the water tank. The water tank was positioned so that the water level was located at 60cm from the focal spot; which also represents the focal spot to interventional reference plane distance for that fluoroscope. Results: PDDs for 60, 80, 100, and 120 kVp with 0 mm of copper filtration compared well to previously published data by Fetterly et al. [Med Phys, 28, 205 (2001)] for those beam qualities given differences in fluoroscopes, geometric orientation, type of ionization chamber, and the water tank used for data collection. PDDs for 60, 80, 100, and 120 kVp with copper filtration were obtained and are presented, which have not been previously investigated and published. Conclusion: The equipment and processes used to acquire the reported data were sound and compared well with previously published data for PDDs without copper filtration. PDD data for the fluoroscopic x-ray beams incorporating copper filtration can be used as reference data for estimating organ or soft tissue dose at depth involving similar beam qualities or for comparison with mathematical models.

  5. Angiographic picture of soft tissue desmoid fibromas

    International Nuclear Information System (INIS)

    Nikitaev, N.S.; Kuznetsova, M.A.

    1987-01-01

    Arteriography was performed in 35 patients with soft tissue desmoid fibromas. Angiographic semiotics of this disease was described. The frequency of detectability of symptoms in the arterial, parenchymatous and venous phases was analyzed. A tumor in the arterial phase was shown to be of normevascular or moderately hypervascular type without noticeable winding of the nutrient arteries, such features of malignancy as lacunae and ''tumor'' vessels being absent. In the parenchymatous phase desmoid tumors were shown to accumulate moderately a contrast substance, a tumor contour at a vast length was ill defined and poorly marked from surrounding tissues. The venous phase was less noticeable and the time of its appearance was usually within normal. In general by most of its parameters the angiographic picture of agressive fibromatosis corresponded to that of benign tumors and could be used for differential diagnosis of desmoid fibromas and some types of tissue sarcomas

  6. Adult Moyamoya disease angiographic images evolutive characters and treatment methods

    International Nuclear Information System (INIS)

    Qian Jiangnan; Ling Feng

    2000-01-01

    Objective: To discuss the angiographic images with evolutional characters and the treatment methods of the Moyamoya disease. Methods: The clinical manifestations, the radiographic changes and the comparative analysis between medicine treatment and surgery treatment, together with the laboratory tests findings were analyzed in one cases adult Moyamoya disease during six years. Conclusions: The angiographic characteristics of MMD show the supplied artery trunk stenosis, and followed by occlusion, with later appearance of vascular smoking sign. Medical treatment proved to be of null. Direct or indirect intra or extra cranial vascular anastomosis are effective for treatment

  7. Integrated cancer therapy combined radiotherapy and immunotherapy. The challenge of using Gc protein-derived macrophage activating factor (GcMAF) as a key molecule

    International Nuclear Information System (INIS)

    Uto, Yoshihiro; Hori, Hitoshi

    2013-01-01

    Radiation oncologists know the conflict between radiotherapy and immunotherapy, but now challenged trails of the integrative cancer therapies combined radiation therapy and various immunoreaction/immune therapies begin. We therefore review the recent results of basic research and clinical trial of the integrated cancer therapies which combined radiotherapy and various immune therapies/immunoreaction, and the challenged studies of combined use of radiotherapy and our developed cancer immunotherapy using serum GcMAF which is human serum containing Gc protein-derived macrophage activating factor (GcMAF). (author)

  8. Essentials of diagnostic and interventional angiographic technique

    International Nuclear Information System (INIS)

    Gerlock, A.J.; Mirfakhraee, M.

    1985-01-01

    This volume presents coverage of basic angiographic techniques and shows how to get to the point of taking the angiogram, and tells how to avoid pitfalls. Particularly valuable is the information on how to get out of trouble if an error is made while manipulating the catheter

  9. Development of DIGITEXαPlus digital angiographic system

    International Nuclear Information System (INIS)

    Imanishi, Tetsuo; Miura, Yusuke; Sasaki, Osamu; Furuyama, Makoto; Yasumi, Masayuki

    2001-01-01

    The functions required of digital angiographic (DA) systems have been noticeably changing with the recent popularization of the technique of interventional radiology (IVR) in the field of angiography. We have developed a new digital angiographic system, named the DIGITEXαPlus, which is designed to meet the requirements of the latest IVR technologies. The DIGITEXαPlus system is equipped with a high-performance one-million-pixel CCD camera, a newly developed F.P.O. (fluoro-power optimizer), and a contrast-priority radiography control system, which combine together to provide high quality of images both in fluoroscopy and in fluorography. In this new system, a low-dose pulsed fluoroscopy method, employed as standard, minimizes the X-ray doses to patients, and an image controller (IVR MASTER) of a joy stick type provides more diversified functions that its predecessors. These two features enhance the reliability, and simplifies the operation, of the IVR system as a whole. (author)

  10. Common fluoroscopic studies in radiology : conduct and analysis method

    International Nuclear Information System (INIS)

    Valverde Sanchez, Allan

    2011-01-01

    A countless number of radiological procedures, that have involved the use of fluoroscopy and contrast media of different indole, have been carried out in all radiology services and medical images of Costa Rica for the diagnosis of diseases or conditions, in both adults and in children. Fluoroscopic studies, often called special or contrast studies, have had particular conditions for its realization. Some from the medical point of view: adequate training in the technical and cognitive development when evaluating the images to not miss important details. Other by the patient: adequate preparation to achieve the best images for optimal diagnosis. For example, adequate bowel preparation is essential for a barium enema, to cooperation by the patient to meet specific indications that the physician dictates when swallowing postures or just when you are prompted. Criteria have been met and unified for contrast studies in different hospitals and clinics. The indications, contra, method, technique of procedure, points to remember, number of images or projections minimum required in the interpretation of contrast studies, as well as a report template of standard and ideal study are presented in a simple, systematic and logical. The manual is intended for residents and attending physicians specialists in radiology and medical imaging including contrast studies more common. Spaces are promoted with current technology studies to set aside more complicated and less sophisticated as have been the fluoroscopic studies; however, in the national reality, access to computerized tomography and magnetic resonance imaging is not as easy. Radiological studies with fluoroscopy performed by trained staff led the treating physician to make sound decisions based on studies relatively simple and easy to do. The tests with the use of fluoroscopic have been named: the esophagogram, gastroduodenal series, gastro intestinal transit, the hysterosalpingography, the cystography and the

  11. Role of fluoroscopic guided self expandable metallic stents in the management of malignant esophageal strictures

    OpenAIRE

    Mohamed Shaker; Ahmed Deif; Amr Abdelaal

    2016-01-01

    Objectives: To evaluate the role of fluoroscopic guided self expanding metallic stents in the management of dysphagia caused by malignant esophageal strictures. Materials and methods: During the period between April 2010 and October 2012, 31 patients with malignant esophageal strictures were subjected to fluoroscopic guided self expanding metallic stent application. The study included 22 males and 9 females ranging in age between 22 and 75 years old with mean age of 56.8 years. Lesions wer...

  12. Measurements for testing of fluoroscopic screens, including the photofluorographic units

    International Nuclear Information System (INIS)

    Balfanz, R.

    1986-01-01

    Image quality control measurements for fluoroscopic screens and photofluorographs have shown that both types of equipment have a long operating life, so that constancy and technical performance tests are absolutely necessary. It is recommended to conclude in-service maintenance contracts with the manufacturers. (DG) [de

  13. Fluoroscopic tomography. [for body section synthesis

    Science.gov (United States)

    Baily, N. A.; Crepeau, R. L.; Lasser, E. C.

    1974-01-01

    A fluoroscopic tomography system capable of synthesizing body sections at a number of levels within the body has been developed. The synthesized body sections may lie either in a range of planes parallel to, tilted with respect to, skewed with respect to, or both tilted and skewed with respect to the plane of motion of the X-ray tube target. In addition, body sections can be presented which are contoured to the patient's anatomy. That is to say, they may even encompass such complex surfaces as a quadratic hyperplane. In addition, tomograms of organs in motion can be imaged.

  14. General-purpose radiographic and fluoroscopic table

    International Nuclear Information System (INIS)

    Ishizaki, Noritaka

    1982-01-01

    A new series of diagnostic tables, Model DT-KEL, was developed for general-purpose radiographic and fluoroscopic systems. Through several investigations, the table was so constructed that the basic techniques be general radiography and GI examination, and other techniques be optionally added. The diagnostic tables involve the full series of the type for various purposes and are systematized with the surrounding equipment. A retractable mechanism of grids was adopted first for general use. The fine grids with a density of 57 lines per cm, which was adopted in KEL-2, reduced the X-ray doses by 16 percent. (author)

  15. Effect of glycoprotein IIb/IIIa receptor inhibition on angiographic complications during percutaneous coronary intervention in the ESPRIT trial.

    Science.gov (United States)

    Blankenship, J C; Tasissa, G; O'Shea, J C; Iliadis, E A; Bachour, F A; Cohen, D J; Lui, H K; Mann, T; Cohen, E; Tcheng, J E

    2001-09-01

    We sought to determine whether eptifibatide decreases the incidence of in-laboratory angiographic complications and to determine the relationship of angiographically evident complications to elevations of creatine kinase-MB (CK-MB) enzyme levels during percutaneous coronary intervention. In the Enhanced Suppression of the Platelet IIb/IIIa Receptor with Integrilin Therapy (ESPRIT) trial, eptifibatide during coronary intervention was associated with decreased ischemic complications at 48 h and 30 days. Patients (n = 2,064) were randomized to placebo versus eptifibatide (two 180 microg/kg boluses 10 min apart and as a continuous infusion of 2 microg/kg per min) during percutaneous coronary stenting. Angiographic complications including major dissection, distal embolization, residual thrombus, abrupt closure, residual stenosis >50% and side-branch occlusion were prospectively recorded by the operator. Creatine kinase-MB levels were measured after the procedure and every 6 h thereafter. The incidence of angiographic complications and CK-MB elevation was determined for eptifibatide versus placebo groups. Eptifibatide-treated patients demonstrated nonsignificant trends toward fewer angiographic complications (10 vs. 12% for placebo patients, p = 0.13) and, for patients with angiographic complications, fewer subsequent CK-MB elevations (43 vs. 50% for placebo patients, p = 0.31). In patients without any angiographic complications, the incidence of CK-MB elevation >3 times the normal was 7% with placebo and 4% with eptifibatide (p = 0.003). Eptifibatide during nonurgent coronary stent intervention only minimally (and insignificantly) reduces the incidence of angiographic complications and subsequent CK-MB elevations in patients developing an angiographic complication. The greater effect is to reduce myocardial infarction in patients undergoing otherwise uneventful coronary stent implantation as well as in the overall study population.

  16. Angiographic study of digital arteries in workers exposed to vinyl chloride

    Energy Technology Data Exchange (ETDEWEB)

    Falappa, P; Magnavita, N; Bergamaschi, A; Colavita, N

    1982-05-01

    Five patients exposed to vinyl chloride were studied by hand angiography and other non-invasive methods, including photoplethysmography, rheography, and thermography. Raynaud's phenomenon was present in all five subjects, while acro-osteolysis affected only one. Organic vascular lesions, such as narrowing, segmentary occlusions of digital arteries and bridge collaterals, were found in angiographic studies. Only one patient did not show clear segmentary occlusions, but his vessels were crooked and diffusely narrowed. Angiographic results appear to correlate well with the changes shown by non-invasive techniques.

  17. Transvenous embolization of cavernous sinus dural arteriovenous fistula via angiographic occlusive inferior petrous sinus

    Directory of Open Access Journals (Sweden)

    Chao-Bao Luo

    2015-09-01

    Conclusion: Angiographic occlusive IPS of CSDAVF may be related to true occlusion of IPS or patent IPS with compartment of the IPS-CS. There is no statistically significant difference in procedural times for these two different fistula anatomies. Transvenous embolization via angiographic occlusive IPS is a safe and effective method to manage CSDAVFs.

  18. Shock Index Correlates with Extravasation on Angiographs of Gastrointestinal Hemorrhage: A Logistics Regression Analysis

    International Nuclear Information System (INIS)

    Nakasone, Yutaka; Ikeda, Osamu; Yamashita, Yasuyuki; Kudoh, Kouichi; Shigematsu, Yoshinori; Harada, Kazunori

    2007-01-01

    We applied multivariate analysis to the clinical findings in patients with acute gastrointestinal (GI) hemorrhage and compared the relationship between these findings and angiographic evidence of extravasation. Our study population consisted of 46 patients with acute GI bleeding. They were divided into two groups. In group 1 we retrospectively analyzed 41 angiograms obtained in 29 patients (age range, 25-91 years; average, 71 years). Their clinical findings including the shock index (SI), diastolic blood pressure, hemoglobin, platelet counts, and age, which were quantitatively analyzed. In group 2, consisting of 17 patients (age range, 21-78 years; average, 60 years), we prospectively applied statistical analysis by a logistics regression model to their clinical findings and then assessed 21 angiograms obtained in these patients to determine whether our model was useful for predicting the presence of angiographic evidence of extravasation. On 18 of 41 (43.9%) angiograms in group 1 there was evidence of extravasation; in 3 patients it was demonstrated only by selective angiography. Factors significantly associated with angiographic visualization of extravasation were the SI and patient age. For differentiation between cases with and cases without angiographic evidence of extravasation, the maximum cutoff point was between 0.51 and 0.0.53. Of the 21 angiograms obtained in group 2, 13 (61.9%) showed evidence of extravasation; in 1 patient it was demonstrated only on selective angiograms. We found that in 90% of the cases, the prospective application of our model correctly predicted the angiographically confirmed presence or absence of extravasation. We conclude that in patients with GI hemorrhage, angiographic visualization of extravasation is associated with the pre-embolization SI. Patients with a high SI value should undergo study to facilitate optimal treatment planning

  19. Real-Time Verification of a High-Dose-Rate Iridium 192 Source Position Using a Modified C-Arm Fluoroscope

    Energy Technology Data Exchange (ETDEWEB)

    Nose, Takayuki, E-mail: nose-takayuki@nms.ac.jp [Department of Radiation Oncology, Nippon Medical School Tamanagayama Hospital, Tama (Japan); Chatani, Masashi [Department of Radiation Oncology, Osaka Rosai Hospital, Sakai (Japan); Otani, Yuki [Department of Radiology, Kaizuka City Hospital, Kaizuka (Japan); Teshima, Teruki [Department of Radiation Oncology, Osaka Medical Center for Cancer and Cardiovascular Diseases, Osaka (Japan); Kumita, Shinichirou [Department of Radiology, Nippon Medical School Hospital, Tokyo (Japan)

    2017-03-15

    Purpose: High-dose-rate (HDR) brachytherapy misdeliveries can occur at any institution, and they can cause disastrous results. Even a patient's death has been reported. Misdeliveries could be avoided with real-time verification methods. In 1996, we developed a modified C-arm fluoroscopic verification of an HDR Iridium 192 source position prevent these misdeliveries. This method provided excellent image quality sufficient to detect errors, and it has been in clinical use at our institutions for 20 years. The purpose of the current study is to introduce the mechanisms and validity of our straightforward C-arm fluoroscopic verification method. Methods and Materials: Conventional X-ray fluoroscopic images are degraded by spurious signals and quantum noise from Iridium 192 photons, which make source verification impractical. To improve image quality, we quadrupled the C-arm fluoroscopic X-ray dose per pulse. The pulse rate was reduced by a factor of 4 to keep the average exposure compliant with Japanese medical regulations. The images were then displayed with quarter-frame rates. Results: Sufficient quality was obtained to enable observation of the source position relative to both the applicators and the anatomy. With this method, 2 errors were detected among 2031 treatment sessions for 370 patients within a 6-year period. Conclusions: With the use of a modified C-arm fluoroscopic verification method, treatment errors that were otherwise overlooked were detected in real time. This method should be given consideration for widespread use.

  20. Correction of malfunctioning peritoneal dialysis catheter with guidewire and stiffener under fluoroscopic guidance

    International Nuclear Information System (INIS)

    Lee, Seung Ryong; Baek, Kyong Hee; Jung, Gyoo Sik; Huh, Jin Do; Joh, Young Duk; Rim, Hark

    1997-01-01

    To determine the efficacy of correction of a malfunctioning peritoneal dialysis catheter with guidewire and stiffener under fluoroscopic guidance. Between November 1994 and March 1997, we performed 15 manipulations in 12 patients in whom a dual-cuff, straight Tenckhoff peritoneal dialysis catheter had been implanted due to chronic renal failure. The causes of catheter malfunctioning were inadequate drainage of the dialysate(n=14) and painful dialysis(n=1). Under fluoroscopic guidance, adhesiolysis and repositioning of the malfunctioning catheter were performed with an Amplatz Super Stiff guidewire and the stiffener from a biliary drainage catheter. The results of procedures were categorized as either immediate or durable success, this latter being defined as adequate catheter function for at least one month after the procedure. Immediate success was achieved in 14 of 15 procedures (93%), and durable success in 7 of 15(47%). The mean duration of catheter function was 157 (range, 30 to 578) days. After manipulation, abdominal pain developed in eight patients and peritonitis in two, but with conservative treatment, these symptoms improved. The correction of a malfunctioning peritoneal dialysis catheter with guidewire and stiffener under fluoroscopic guidance is an effective means of restoring catheter function and may be an effective alternative to surgical reimplantation of the catheter, or hemodialysis

  1. Correction of malfunctioning peritoneal dialysis catheter with guidewire and stiffener under fluoroscopic guidance

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Seung Ryong; Baek, Kyong Hee; Jung, Gyoo Sik; Huh, Jin Do; Joh, Young Duk; Rim, Hark [Kosin Medical College, Pusan (Korea, Republic of)

    1997-11-01

    To determine the efficacy of correction of a malfunctioning peritoneal dialysis catheter with guidewire and stiffener under fluoroscopic guidance. Between November 1994 and March 1997, we performed 15 manipulations in 12 patients in whom a dual-cuff, straight Tenckhoff peritoneal dialysis catheter had been implanted due to chronic renal failure. The causes of catheter malfunctioning were inadequate drainage of the dialysate(n=14) and painful dialysis(n=1). Under fluoroscopic guidance, adhesiolysis and repositioning of the malfunctioning catheter were performed with an Amplatz Super Stiff guidewire and the stiffener from a biliary drainage catheter. The results of procedures were categorized as either immediate or durable success, this latter being defined as adequate catheter function for at least one month after the procedure. Immediate success was achieved in 14 of 15 procedures (93%), and durable success in 7 of 15(47%). The mean duration of catheter function was 157 (range, 30 to 578) days. After manipulation, abdominal pain developed in eight patients and peritonitis in two, but with conservative treatment, these symptoms improved. The correction of a malfunctioning peritoneal dialysis catheter with guidewire and stiffener under fluoroscopic guidance is an effective means of restoring catheter function and may be an effective alternative to surgical reimplantation of the catheter, or hemodialysis.

  2. Fluoroscopic-guided covered metallic stent placement for gastric outlet obstruction and post-operative gastroenterostomy anastomotic stricture

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jeong Min; Han, Young Min; Kim, Chong Soo; Lee, Sang Young; Lee, Soo Teik; Yang, Doo Hyun

    2001-07-01

    AIM: To evaluate the feasibility and safety of fluoroscopic-guided covered metallic stent placements in providing palliative care for patients with inoperable malignant gastric outlet obstruction. MATERIALS AND METHODS: Under fluoroscopic guidance, placement of self-expandable, covered stents was attempted in 20 patients with inoperable or recurrent gastric cancer (age range 36-79 years). All patients had inoperable gastric outlet obstruction, 13 with native anatomy and seven with post-operative anatomy (gastrointestinal anastomotic sites). All patients had intolerance to oral alimentation and/or vomiting after ingestion. Success was defined both technically and clinically. RESULTS: The placement of the stent was technically successful in 18 patients and failed in two patients (technical success: 90%). The cause of the technical failures was an inability to negotiate the guide wire through the obstruction sites in spite of the use of both fluoroscopic and endoscopic guidance. After stent placement, 15 patients were able to ingest at least liquids and had a markedly decreased incidence of vomiting (clinical success: 75%). During the mean follow-up of 6 weeks, there have been no stent reocclusion and no life-threatening complications except migration of two stents in one patient. CONCLUSION: Fluoroscopically guided covered metallic stent placement appears to be valuable for the palliative treatment of malignant obstruction of gastric outlet and post-operative gastrointestinal anastomoses. Lee, J.M. et al. (2001)

  3. Multivariate Alteration Detection (MAD) and MAF Postprocessing in Multispectral, Bitemporal Image Data: New Approaches to Change Detection Studies

    DEFF Research Database (Denmark)

    Nielsen, Allan Aasbjerg; Conradsen, Knut; Simpson, James J.

    1998-01-01

    type analyses of simple difference images. Case studies with AHVRR and Landsat MSS data using simple linear stretching and masking of the change images show the usefulness of the new MAD and MAF/MAD change detection schemes. Ground truth observations confirm the detected changes. A simple simulation...

  4. Echocardiographic and Fluoroscopic Fusion Imaging for Procedural Guidance: An Overview and Early Clinical Experience.

    Science.gov (United States)

    Thaden, Jeremy J; Sanon, Saurabh; Geske, Jeffrey B; Eleid, Mackram F; Nijhof, Niels; Malouf, Joseph F; Rihal, Charanjit S; Bruce, Charles J

    2016-06-01

    There has been significant growth in the volume and complexity of percutaneous structural heart procedures in the past decade. Increasing procedural complexity and accompanying reliance on multimodality imaging have fueled the development of fusion imaging to facilitate procedural guidance. The first clinically available system capable of echocardiographic and fluoroscopic fusion for real-time guidance of structural heart procedures was approved by the US Food and Drug Administration in 2012. Echocardiographic-fluoroscopic fusion imaging combines the precise catheter and device visualization of fluoroscopy with the soft tissue anatomy and color flow Doppler information afforded by echocardiography in a single image. This allows the interventionalist to perform precise catheter manipulations under fluoroscopy guidance while visualizing critical tissue anatomy provided by echocardiography. However, there are few data available addressing this technology's strengths and limitations in routine clinical practice. The authors provide a critical review of currently available echocardiographic-fluoroscopic fusion imaging for guidance of structural heart interventions to highlight its strengths, limitations, and potential clinical applications and to guide further research into value of this emerging technology. Copyright © 2016 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.

  5. Micro-angiography for neuro-vascular imaging. I. Experimental evaluation and feasibility

    International Nuclear Information System (INIS)

    Ganguly, Arundhuti; Rudin, Stephen; Bednarek, Daniel R.; Hoffmann, Kenneth R.; Kyprianou, Iacovos S.

    2003-01-01

    Minimally invasive image-guided neuro-vascular interventions require very high image-resolution and quality, specifically over regions-of-interest (ROI) crucial to the procedure. ROI imaging or micro-angiography, allows limited patient integral radiation dose while permitting rapid frame transfer of high-resolution images. The design and performance of a charge coupled device (CCD) based x-ray detector or micro-angiographic camera was assessed for neuro-vascular procedures. The detector consists of a 250-μm-thick CsI(Tl) phosphor fiber-optically coupled through a 1.8:1 taper to a CCD chip, with an effective image pixel size of 50 μm and a frame rate of 5 fps in the 2:1 pixel-binned mode. The characteristics of the camera including the modulation transfer function (MTF), the noise equivalent quanta, the detective quantum efficiency, observer studies, and the effect of geometric magnification were evaluated. The MTF was found to have nonzero (1.7%) value at the Nyquist frequency of 10 cycles/mm, while the DQE(0) had a value of ∼55%. All values were measured using head equivalent attenuating material in the beam at 80 kVp. Human observer studies performed using the 2 Alternative Forced Choice method revealed that iodinated vessels with inner diameter of 100 μm and 2 cm in length can be seen with a confidence level greater than 75%. The observer studies included a comparison with ideal observer performance calculations based on the integral signal to noise ratio in the image. Probabilities of visualization of various objects of interest in a neuro-intervention, such as stents, were assessed. A geometric magnification of 1 was found to be best for imaging under neuro-angiographic conditions. The detector appeared to satisfy all the demands of neuro-angiography and showed promise as an improvement over existing angiographic detectors

  6. Use of guiding sheaths in peroral fluoroscopic gastroduodenal stent placement

    International Nuclear Information System (INIS)

    Bae, Jae-Ik; Shin, Ji Hoon; Song, Ho-Young; Yoon, Chang Jin; Nam, Deok Ho; Choi, Won-Chan; Lim, Jin-Oh

    2005-01-01

    Our purpose was to assess the safety and usefulness of guiding sheaths in peroral fluoroscopic gastroduodenal stent placement. Two types of guiding sheath were made from straight polytetrafluoroethylene tubes. Type A was 80 cm in length, 4 mm in outer diameter and 3 mm in inner diameter. Type B was 70 cm in length, 6 mm in outer diameter and 5 mm in inner diameter. The type A sheath was used in 18 patients in whom a catheter-guide wire combination failed to pass through a stricture. The type B sheath was used in 22 patients in whom a stent delivery system failed to pass through the stricture due to loop formation within the gastric lumen. The overall success rate for guiding a catheter-guide wire through a stricture after using the type A sheath was 89%. The overall success rate for passing a stent delivery system through a stricture after using the type B sheath was 100%. All procedures were tolerated by the patients without any significant complications. The guiding sheaths were safe and useful in peroral fluoroscopic gastroduodenal stent placement. (orig.)

  7. Short-term outcome of fluoroscopic-guided steroid injection therapy of lumber facet cyst-induced radicular pain

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Mi Ri; Kwon, Jong Won; Lee, Jong Seo; Kim, Eu Sang [Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2015-04-15

    To determine the short-term effect of fluoroscopic-guided steroid injection therapy of lumbar facet cyst-induced radicular pain. Seventeen patients with radiculopathy due to lumbar synovial cysts, who were treated with fluoroscopically guided injection, were retrospectively evaluated. All plain radiographic images and MR images before the therapy were reviewed. Five patients underwent only the facet joint injection, whereas twelve patients underwent the facet joint injection with perineural injection therapy. The clinical course of pain was evaluated on the first follow-up after therapy. Effective pain relief was achieved in 11 (64.7%) of the 17 patients. Among 12 patients who underwent facet joint injection with perineural injection, 9 patients (75%) had an effective pain relief. Of 5 patients, 2 (40%) patients only took the facet joint injection and had an effective pain relief. Fluoroscopic-guided steroid injection therapy shows a good short-term effect in patients with symptomatic lumbar facet joint synovial cysts.

  8. Image quality evaluation and patient dose assessment of medical fluoroscopic X-ray systems: A national study

    International Nuclear Information System (INIS)

    Economides, S.; Hourdakis, C. J.; Kalivas, N.; Kalathaki, M.; Simantirakis, G.; Tritakis, P.; Manousaridis, G.; Vogiatzi, S.; Kipouros, P.; Boziari, A.; Kamenopoulou, V.

    2008-01-01

    This study presents the results from a survey conducted by the Greek Atomic Energy Commission (GAEC), during the period 1998-2003, in 530 public and private owned fluoroscopic X-ray systems in Greece. Certain operational parameters for conventional and remote control systems were assessed, according to a quality control protocol developed by GAEC on the basis of the current literature. Public (91.5%) and private (81.5%) owned fluoroscopic units exhibit high-contrast resolution values over 1 lp mm -1 . Moreover, 88.5 and 87.1% of the fluoroscopic units installed in the public and private sector, respectively, present Maximum Patient Entrance Kerma Rate values lower than 100 mGy min -1 . Additionally, 68.3% of the units assessed were found to perform within the acceptance limits. Finally, the third quartile of the Entrance Surface Dose Rate distribution was estimated according to the Dose Reference Level definition and found equal to 35 mGy min -1 . (authors)

  9. Nonsurgical Fluoroscopically Guided Dacryocystoplasty of Common Canalicular Obstructions

    Energy Technology Data Exchange (ETDEWEB)

    Wilhelm, Kai E; Hofer, Ulrich; Textor, Hans J [Department of Radiology, University Hospital Bonn, Sigmund-Freud-Strasse 25, D-53127 Bonn (Germany); Boeker, Thorsten [Department of Ophthalmology, University Hospital Bonn, Sigmund-Freud-Strasse 25, D-53127 Bonn (Germany); Strunk, Holger; Schild, Hans H [Department of Radiology, University Hospital Bonn, Sigmund-Freud-Strasse 25, D-53127 Bonn (Germany)

    2000-01-15

    Purpose: To assess dacryocystoplasty in the treatment of epiphora due to obstructions of the common canaliculus.Methods: Twenty patients with severe epiphora due to partial (n = 16) or complete (n = 4) obstruction of the common canaliculus underwent fluoroscopically guided dacryocystoplasty. In all cases of incomplete obstruction balloon dilation was performed. Stent implantation was attempted in cases with complete obstruction. Dacryocystography and clinical follow-up was performed at intervals of 1 week, and 3, 6, 12, and 18 months after the procedure. The mean follow-up was 6 months (range 3-18 months).Results: Balloon dilation was technically successfully performed in all patients with incomplete obstructions (n = 16). In three of four patients with complete obstruction stent implantation was performed successfully. Subsequent to failure of stent implantation in one of these patients balloon dilation was performed instead. The long-term primary patency rate in patients with incomplete obstructions was 88% (n = 14/16). In three of four cases with complete obstruction long-term patency was achieved during follow-up. Severe complications, infections, or punctal splitting were not observed.Conclusion: Fluoroscopically guided balloon dacryocystoplasty is a feasible nonsurgical therapy in canalicular obstructions with good clinical results that may be used as an alternative to surgical procedures. In patients with complete obstructions stent placement is possible but further investigations are needed to assess the procedural and long-term results.

  10. Nonsurgical Fluoroscopically Guided Dacryocystoplasty of Common Canalicular Obstructions

    International Nuclear Information System (INIS)

    Wilhelm, Kai E.; Hofer, Ulrich; Textor, Hans J.; Boeker, Thorsten; Strunk, Holger; Schild, Hans H.

    2000-01-01

    Purpose: To assess dacryocystoplasty in the treatment of epiphora due to obstructions of the common canaliculus.Methods: Twenty patients with severe epiphora due to partial (n = 16) or complete (n = 4) obstruction of the common canaliculus underwent fluoroscopically guided dacryocystoplasty. In all cases of incomplete obstruction balloon dilation was performed. Stent implantation was attempted in cases with complete obstruction. Dacryocystography and clinical follow-up was performed at intervals of 1 week, and 3, 6, 12, and 18 months after the procedure. The mean follow-up was 6 months (range 3-18 months).Results: Balloon dilation was technically successfully performed in all patients with incomplete obstructions (n = 16). In three of four patients with complete obstruction stent implantation was performed successfully. Subsequent to failure of stent implantation in one of these patients balloon dilation was performed instead. The long-term primary patency rate in patients with incomplete obstructions was 88% (n = 14/16). In three of four cases with complete obstruction long-term patency was achieved during follow-up. Severe complications, infections, or punctal splitting were not observed.Conclusion: Fluoroscopically guided balloon dacryocystoplasty is a feasible nonsurgical therapy in canalicular obstructions with good clinical results that may be used as an alternative to surgical procedures. In patients with complete obstructions stent placement is possible but further investigations are needed to assess the procedural and long-term results

  11. Micro-angiographic investigations of revascularisation of fracture in the canine tibia

    Energy Technology Data Exchange (ETDEWEB)

    Kagel, K.O.; Koecher, W.

    1987-03-01

    Micro-angiograms were performed between eight weeks and one year following osteotomies and pressure osteosyntheses in 34 dog tibiae. Seventeen animals also underwent lumbar sympathectomy. In more than half of the cases, vascularisation of the medulla was reduced by damage to the nutrient artery. Segmental connections could be demonstrated by means of transcortical anastomoses. Following sympathectomy, revascularisation was more marked as a result of numerous trans-osseus anastomoses. This, however, did not lead to improved healing; healing was worse after sympathectomy. Transcortical revascularisation and vessel growth along drill holes are of crucial significance.

  12. Micro-angiographic investigations of revascularisation of fracture in the canine tibia

    International Nuclear Information System (INIS)

    Kagel, K.O.; Koecher, W.; Ernst-Moritz-Arndt-Universitaet, Greifswald

    1987-01-01

    Micro-angiograms were performed between eight weeks and one year following osteotomies and pressure osteosyntheses in 34 dog tibiae. Seventeen animals also underwent lumbar sympathectomy. In more than half of the cases, vascularisation of the medulla was reduced by damage to the nutrient artery. Segmental connections could be demonstrated by means of transcortical anastomoses. Following sympathectomy, revascularisation was more marked as a result of numerous trans-osseus anastomoses. This, however, did not lead to improved healing; healing was worse after sympathectomy. Transcortical revascularisation and vessel growth along drill holes are of crucial significance. (orig.) [de

  13. Serum high sensitivity C-reactive protein levels and the severity of coronary atherosclerosis assessed by angiographic gensini score

    International Nuclear Information System (INIS)

    Masood, A.; Jafar, S.S.; Akram, Z.

    2011-01-01

    Objective: To assess the relationship between plasma high sensitivity C-reactive protein levels with severity of coronary atherosclerosis. Materials and Methods: The study included 80 patients subjected to coronary angiography. The extent of Coronary Artery Disease (CAD) was assessed using Gensini score. Patients were divided into three risk groups according to hs-CRP levels ( 3mg/L- as high risk). Mean Angiographic Gensini scores were compared among the risk groups. Correlation between serum hs-CRP levels and angiographic Gensini scores was also assessed. Results: The 26 (32.5%) patients belonging to hs-CRP low-risk group had a mean angiographic Gensini score of 11.8 +- 5.8, 18 (22.5%) belonging to moderate-risk group had a mean score of 28.9 +- 7.9 and 36 (45%) belonging to high- risk group had a mean score of 78.7 +- 41.0. By applying ANOVA the mean angiographic Gensini scores showed increasing trend from lower to higher hs-CRP risk groups (p < 0.001). Serum hs-CRP levels showed significant correlation with respective angiographic Gensini scores by Pearson's correlation (p < 0.001). Conclusion: Serum hs-CRP levels show significant correlation with the severity of Coronary Artery Disease as assessed by angiographic Gensini score. (author)

  14. Hepatic angiographic findings of ruptured hepatocellular carcinoma: 'Sentinel signs' versus extravasation

    International Nuclear Information System (INIS)

    Yun, Seong Jong; Nam, Deok Ho

    2014-01-01

    This study retrospectively compared the accuracy of angiographic sentinel signs (sentinel vessels, hypovascular areas, and delayed dots) with extravasation in the diagnosis of ruptured hepatocellular carcinoma (HCC). Sixteen patients diagnosed with HCC between March 2007 and November 2011 were evaluated. Among the patients, we identified 32 HCCs (19 ruptured, 13 unruptured), and assessed all HCCs by hepatic angiography with regard to extravasation, sentinel vessels, hypovascular areas, and delayed dots. We compared the sensitivity and specificity of the sentinel signs with those of the extravasation for the diagnosis of a ruptured HCC. For the angiographic diagnosis of a ruptured HCC, the sensitivity of the sentinel signs (sentinel vessel, 63.2%; hypovascular area, 89.5%; delayed dot, 72.7%) was higher than the sensitivity of extravasation (15.8%). The difference in sensitivity between each sentinel sign and extravasation was statistically significant (sentinel vessel, p = 0.012; hypovascular area, p < 0.001; delayed dot, p 0.039). The specificity of sentinel signs for the diagnosis of ruptured HCC was not statistically different from the specificity of extravasation. Sentinel signs are more accurate than extravasation for the angiographic diagnosis of a ruptured HCC.

  15. Transarterial embolization in the management of intractable epistaxis: the angiographic findings and results based on etiologies.

    Science.gov (United States)

    Wang, Bin; Zu, Qing-Quan; Liu, Xing-Long; Zhou, Chun-Gao; Xia, Jin-Guo; Zhao, Lin-Bo; Shi, Hai-Bin; Liu, Sheng

    2016-08-01

    Transarterial embolization (TAE) appears to be a safe and effective treatment for patients with intractable epistaxis, despite different etiologies or angiography findings. Idiopathic epistaxis is prone to present with negative angiographic findings. To retrospectively evaluate the safety and effectiveness of TAE for intractable epistaxis, and focus on the factors of etiology and angiographic findings. From March 2008 to December 2014, the data of 43 patients with intractable bleeding undergoing TAE were reviewed. The outcomes of interventional therapy were assessed according to different etiology (malignant or benign disease) and angiographic finding (positive or negative angiogram). Positive angiographic findings were found in 11 of 12 cases with malignant diseases and 22 of 31 cases with benign diseases, respectively (p = 0.237). Among the 10 cases with negative angiographic findings, the negative angiography rate of idiopathic epistaxis was higher than that of epistaxis with definite etiology (p = 0.003). Bleeding was controlled successfully in all of the 43 patients after embolization. During the mean follow-up period of 24.0 ± 16.7 months, five patients relapsed. No significant difference was found in recurrence rates between malignant and benign diseases or between positive and negative angiography (p = 0.241, p = 0.704, respectively).

  16. Cerebral angiographic changes on serial examination of a patient with migraine

    Energy Technology Data Exchange (ETDEWEB)

    Masuzawa, T.; Shinoda, S.; Nakahara, N.; Abe, F.; Sato, F.; Furuse, M.

    1983-03-01

    Curious cerebral angiographic changes are described in a 27-year-old female migraine patient. During the period of observation of this patient, both the intracranial carotid artery and the vertebrobasilar artery systems presented unusual and fascinating cerebral arteriographic pictures. In an attack of migraine, angiography showed that all the intracranial secondary and tertiary branches of the carotid arterial system were dilated without showing any changes in the extracranial arteries and when the migraine attack had subsided, all branches of the carotid arteries as well as the vertebrobasilar arteries demonstreated abnormal segmental narrowings or vasospasm. These sequential angiographic changes have not been hitherto reported in migraine.

  17. Renal artery origins: best angiographic projection angles.

    Science.gov (United States)

    Verschuyl, E J; Kaatee, R; Beek, F J; Patel, N H; Fontaine, A B; Daly, C P; Coldwell, D M; Bush, W H; Mali, W P

    1997-10-01

    To determine the best projection angles for imaging the renal artery origins in profile. A mathematical model of the anatomy at the renal artery origins in the transverse plane was used to analyze the amount of aortic lumen that projects over the renal artery origins at various projection angles. Computed tomographic (CT) angiographic data about the location of 400 renal artery origins in 200 patients were statistically analyzed. In patients with an abdominal aortic diameter no larger than 3.0 cm, approximately 0.5 mm of the proximal part of the renal artery and origin may be hidden from view if there is a projection error of +/-10 degrees from the ideal image. A combination of anteroposterior and 20 degrees and 40 degrees left anterior oblique projections resulted in a 92% yield of images that adequately profiled the renal artery origins. Right anterior oblique projections resulted in the least useful images. An error in projection angle of +/-10 degrees is acceptable for angiographic imaging of the renal artery origins. Patients sex, site of interest (left or right artery), and local diameter of the abdominal aorta are important factors to consider.

  18. TU-FG-209-05: Demonstration of the Line Focus Principle Using the Generalized Measured-Relative Object Detectability (GM-ROD) Metric

    Energy Technology Data Exchange (ETDEWEB)

    Russ, M; Shankar, A; Lau, A; Bednarek, D; Rudin, S [University at Buffalo (SUNY), Buffalo, NY (United States)

    2016-06-15

    Purpose: Demonstrate and quantify the augmented resolution due to focalspot size decrease in images acquired on the anode side of the field, for both small and medium (0.3 and 0.6mm) focal-spot sizes using the experimental task-based GM-ROD metric. Theoretical calculations have shown that a medium focal-spot can achieve the resolution of a small focal-spot if acquired with a tilted anode, effectively providing a higher-output small focal-spot. Methods: The MAF-CMOS (micro-angiographic fluoroscopic complementary-metal-oxide semiconductor) detector (75µm pixel pitch) imaged two copper wire segments of different diameter and a pipeline stent at the central axis and on the anode side of the beam, achieved by tilting the x-ray C-arm (Toshiba Infinix) to 6° and realigning the detector with the perpendicular ray to correct for x-ray obliquity. The relative gain in resolution was determined using the GM-ROD metric, which compares images on the basis of the Fourier transform of the image and the measured NNPS. To emphasize the geometric unsharpness, images were acquired at a magnification of two. Results: Images acquired on the anode side were compared to those acquired on the central axis with the same target-area focal-spot to consider the effect of an angled tube, and for all three objects the advantage of the smaller effective focal-spot was clear, showing a maximum improvement of 36% in GM-ROD. The images obtained with the small focal-spot at the central axis were compared to those of the medium focal-spot at the anode side and, for all objects, the relative performance was comparable. Conclusion: For three objects, the GM-ROD demonstrated the advantage of the anode side focal-spot. The comparable performance of the medium focal-spot on the anode side will allow for a high-output small focal-spot; a necessity in endovascular image-guided interventions. Partial support from an NIH grant R01EB002873 and an equipment grant from Toshiba Medical Systems Corp.

  19. TU-FG-209-05: Demonstration of the Line Focus Principle Using the Generalized Measured-Relative Object Detectability (GM-ROD) Metric

    International Nuclear Information System (INIS)

    Russ, M; Shankar, A; Lau, A; Bednarek, D; Rudin, S

    2016-01-01

    Purpose: Demonstrate and quantify the augmented resolution due to focalspot size decrease in images acquired on the anode side of the field, for both small and medium (0.3 and 0.6mm) focal-spot sizes using the experimental task-based GM-ROD metric. Theoretical calculations have shown that a medium focal-spot can achieve the resolution of a small focal-spot if acquired with a tilted anode, effectively providing a higher-output small focal-spot. Methods: The MAF-CMOS (micro-angiographic fluoroscopic complementary-metal-oxide semiconductor) detector (75µm pixel pitch) imaged two copper wire segments of different diameter and a pipeline stent at the central axis and on the anode side of the beam, achieved by tilting the x-ray C-arm (Toshiba Infinix) to 6° and realigning the detector with the perpendicular ray to correct for x-ray obliquity. The relative gain in resolution was determined using the GM-ROD metric, which compares images on the basis of the Fourier transform of the image and the measured NNPS. To emphasize the geometric unsharpness, images were acquired at a magnification of two. Results: Images acquired on the anode side were compared to those acquired on the central axis with the same target-area focal-spot to consider the effect of an angled tube, and for all three objects the advantage of the smaller effective focal-spot was clear, showing a maximum improvement of 36% in GM-ROD. The images obtained with the small focal-spot at the central axis were compared to those of the medium focal-spot at the anode side and, for all objects, the relative performance was comparable. Conclusion: For three objects, the GM-ROD demonstrated the advantage of the anode side focal-spot. The comparable performance of the medium focal-spot on the anode side will allow for a high-output small focal-spot; a necessity in endovascular image-guided interventions. Partial support from an NIH grant R01EB002873 and an equipment grant from Toshiba Medical Systems Corp.

  20. Trial manufacture of round mask for TV fluoroscopic unit

    International Nuclear Information System (INIS)

    Matsuoka, Shoji; Matsumoto, Yukio

    1977-01-01

    Demands for revision of existing medical law were described together with an introduction of TV fluoroscopic unit. Round mask, which does not always press out the bottom face of used x-ray beam from the effective primary fluorescent face of photomultiplier inspite of shifting of a spot in time of TV fluoroscopy, was manufactured for trial, and it was furnished with already established fluoroscopic stand. It is used in daily examination without any trouble. Round mask was divided into two parts, and opened upward and downward quickly by lod motor in time of photographing. Multiple iris was operated in order to fit to film size, and round mask was closed at the same time of the finishment of photographing and fluoroscopy was performed again. Item 3 of Para 2 of Art 30 of the existing medical low states that it is good not to press out, the distance between x-ray focus and fluorescent screen, and used x-ray beam from fluorescent screen. However, a regulation, which states that x-ray beam should not be pressed out from effective primary fluorescent face in x-ray fluoroscopy using photomultiplier, must be added. Improvement of the existing unit is expected, and decrease of unnecessary exposure even in small amount is proposed. (Tsunoda, M.)

  1. Economic evaluation of angiographic interventions including a whole-radiology in- and outpatient care

    International Nuclear Information System (INIS)

    Nolte-Ernsting, C.; Abel, K.; Krupski, G.; Lorenzen, J.; Adam, G.

    2006-01-01

    Purpose: To determine the economic efficiency of a whole-radiology in- and outpatient treatment with angiographic interventions performed as the main or sole therapy. Materials and Methods: The calculations represent the data of a university radiology department, including the following angiographic interventions (neuroradiology not considered): Vascular intervention (PTA, stent implantation) of kidneys and extremities, recanalization of hemodialysis access, chemoembolization, diagnostic arterioportal liver CT, port implantation, varicocele embolization, PTCD, percutaneous implantation of biliary stent. First, the different angiographic interventions are categorized with reference to the German DRG system 2005. Considering the example of a university hospital, the individual cost of each intervention is calculated and correlated with reimbursements by G-DRG2005 and so-called ''ambulant operation'' (EBM200plus). With these data, profits and losses are calculated for both in- and outpatient care. Results: Radiologic interventions of inpatients yield a profit in the majority of cases. With a base rate of 2900 Euro, the profits in our university hospital range between -872 Euro and +3411 Euro (mean: +1348 Euro). On the other hand, those angiographic interventions suitable for ''ambulant operation'' generate average profits of +372 Euro, if only direct costs are considered. The data of outpatient radiological interventions average between 381 Euro up to 1612 Euro lower than compared with profits obtained from in patient care. (orig.)

  2. Estimation of breast doses and breast cancer risk associated with repeated fluoroscopic chest examinations of women with tuberculosis

    International Nuclear Information System (INIS)

    Boice, J.D. Jr.; Rosenstein, M.; Trout, E.D.

    1978-01-01

    A methodology is presented to estimate cumulative breast dose and breast cancer risk for women exposed to repeated fluoroscopic chest examinations during air collapse therapy for pulmonary tuberculosis. Medical record abstraction, physician interview, patient contact, machine exposure measurements, and absorbed dose computations were combined to estimate average breast doses for 1047 Massachusetts women who were treated between 1930 and 1954. The methodology presented considers breast size and composition, patient orientation, x-ray field size and location, beam quality, type of examination, machine exposure rate, and exposure time during fluoroscopic examinations. The best estimate for the risk of radiation-induced cancer for the women living longer than 10 years after initial fluoroscopic exposure is 6.2 excess breast cancers per million woman-year-rad with 90% confidence limits of 2.8 and 10.7 cancers/10 6 WY-rad. When breast cancer risk is considered as a function of absorbed dose in the breast, instead of as a function of the number of fluoroscopic examinations, a linear dose--response relationship over the range of estimated doses is consistent with the data. However, because of the uncertainty due to small-sample variability and because of the wide range of assumptions regarding certain fluoroscopy conditions, other dose--response relationships are compatible with the data

  3. Clinical and angiographic predictors of haemodynamically significant angiographic lesions: development and validation of a risk score to predict positive fractional flow reserve.

    Science.gov (United States)

    Sareen, Nishtha; Baber, Usman; Kezbor, Safwan; Sayseng, Sonny; Aquino, Melissa; Mehran, Roxana; Sweeny, Joseph; Barman, Nitin; Kini, Annapoorna; Sharma, Samin K

    2017-04-07

    Coronary revascularisation based upon physiological evaluation of lesions improves clinical outcomes. Angiographic or visual stenosis assessment alone is insufficient in predicting haemodynamic stenosis severity by fractional flow reserve (FFR) and therefore cannot be used to guide revascularisation, particularly in the lesion subset system formulated. Of 1,023 consecutive lesions (883 patients), 314 (31%) were haemodynamically significant. Characteristics associated with FFR ≤0.8 include male gender, higher SYNTAX score, lesions ≥20 mm, stenosis >50%, bifurcation, calcification, absence of tortuosity and smaller reference diameter. A user-friendly integer score was developed with the five variables demonstrating the strongest association. On prospective validation (in 279 distinct lesions), the increasing value of the score correlated well with increasing haemodynamic significance (C-statistic 0.85). We identified several clinical and angiographic characteristics and formulated a scoring system to guide the approach to intermediate lesions. This may translate into cost savings. Larger studies with prospective validation are required to confirm our results.

  4. Coronary arterial Disease associated with arteriosclerosis in lower extremity: Angiographic analysis

    International Nuclear Information System (INIS)

    Kim, Ji Hye; Chung, Jin Wook; Lee, Seon Kyu; Han, Joon Koo; Park, Jae Hyung; Kim, Jae Seung; Han, Man Chung

    1993-01-01

    We performed both peripheral and coronary angiographies in 52 patients with an arteriosclerosis in lower extremities. The severity of arteriosclerotic narrowing of the coronary and peripheral arteries were compared on angiographies. An angiographic vascular score(AVS, 0-5) reflecting the number and the degree of stenosis in 12 lower extremity arteries and three major coronary arteries was assigned to each angiogram and the sun of scores in the lower extremity arteries was compared with the incidence of significant coronary artery disease (more than grade 3) and coronary score. Relation of incidence and severity of vascular stenosis and risk factors (diabetes metallitus, hypertension, smoking, and hypercholesterolemia) was also analyzed. Thirty-four of 52 patients (65%) had an angiographically significant coronary artery disease. Thirteen of these 34 patients (38%) had no clinical symptom and sign of the ischemic heart disease. There was no statistically significant difference in the incidence and severity of coronary artery disease between high (more than 30) and low AVS group in lower extremity (p>0.14). All patients had at least one risk factor and 49 of 52 patients (94%) had multiple risk factors. Coronary angiography was normal in there patients with only one risk factors, and angiographically significant coronary artery disease existed in nine of 16 cases (56.3%) with two risk factors. 13 of 17 case (76.5%) with three risk factors, and 12 of 16 cases (75.0%) with all four risk factors. There were no significant correlations between individual risk factors and incidence, severity of arteriosclerosis in coronary and lower extremity arteries. In conclusion, angiographic evaluation of the coronary artery disease in patients with lower extremity arteriosclerosis is necessary because of the high chance of coronary artery disease and difficulty in the prediction of coronary artery disease with a severity of the peripheral arteriosclerosis, presence of various risk

  5. Staff dosimetry and risk assessment during digestive and angiographic examinations

    International Nuclear Information System (INIS)

    Pages, J.; Osteaux, M.

    2001-01-01

    The use of ionizing radiation in medical applications involves not only a risk for the patient, but also for the staff which executed the related examinations. The dose to the forehead, neck, fingers and wrist of a radiologist and an assisting nurse were measured with thermoluminescent dosimeters during angiographic and digestive examinations respectively. Dose to eye lenses and effective dose were estimated for a working period of one year. Effective doses were under the established limit of 20 mSv per year. Nurse eye lens dose was higher than the limit of 150 mSv. Differences of a factor of 3.8 were observed between nurse and radiologist doses. Angiographic procedures are considered as high risk examinations, however, digestive examinations can have a higher risk than interventional procedures. (author)

  6. The pharmaco-kinetics of angiographic contrast media with special reference to the extravascular spaces. Fundamental studies on dogs for the characterization of angiographic media. Pt. 1

    International Nuclear Information System (INIS)

    Lagemann, K.

    1975-01-01

    The pharmaco-kinetics of angiographic contrast media in the extra-vascular space, which are largely unknown, were investigated experimentally in dogs. As part of a basic study, using radio-active contrast media, it was possible to determine the concentration and rate of elimination in practically all organs and tissues. Measurements were carried out first after prolonged infusion of contrast under conditions of balanced flow, and secondly six hours after the end of the infusion. It was therefore possible to determine the inflow and loss of contrast medium in various organs, or organs systems. The most commonly used angiographic contrast media in Germany were investigated. Their kinetic behaviour is largely identical, their pattern of distribution and elimination depended principally on the organ or tissue. (orig.) [de

  7. Micro-angiography for neuro-vascular imaging. II. Cascade model analysis

    International Nuclear Information System (INIS)

    Ganguly, Arundhuti; Rudin, Stephen; Bednarek, Daniel R.; Hoffmann, Kenneth R.

    2003-01-01

    A micro-angiographic detector was designed and its performance was previously tested to evaluate its feasibility as an improvement over current x-ray detectors for neuro-interventional imaging. The detector was shown to have a modulation transfer function value of about 2% at the Nyquist frequency of 10 cycles/mm and a zero frequency detective quantum efficiency [DQE(0)] value of about 55%. An assessment of the system was required to evaluate whether the current system was performing at its full potential and to determine if any of its components could be optimized to further improve the output. For the purpose, in this study, the parallel cascade theory was used to analyze the performance of the detector under neuro-angiographic conditions by studying the output at the various stages in the imaging chain. A simple model for the spread of light in the CsI(Tl) entrance phosphor was developed and the resolution degradation due to K-fluorescence absorption was calculated. The total gain of the system was found to result in 21 e - (rms) detected at the charge coupled device per absorbed x-ray photon. The gain and the spread of quanta in the imaging chain were used to calculate theoretically the DQE using the parallel cascade model. The results of the model-based calculations matched fairly well with the experimental data previously obtained. This model was then used to optimize the phosphor thickness for the detector. The results showed that the area under the DQE curve had a maximum value at 150 μm of CsI(Tl), though when weighted by the squared signal in frequency space of a 100-μm-diam iodinated vessel, the integral DQE reached a maximum at 250 μm of CsI(Tl). Further, possible locations for gain increase in the imaging chain were determined, and the output of the improved system was simulated. Thus a theoretical analysis for the micro-angiographic detector was performed to better assess its potential

  8. Percutaneous ethanol injection under interventional radiographic computed tomography-fluoroscopic guidance for the treatment of small hepatocellular carcinomas

    Energy Technology Data Exchange (ETDEWEB)

    Furuse, Junji; Satake, Mitsuo; Iwasaki, Masahiko; Sekiguchi, Ryuzo; Moriyama, Noriyuki; Yoshino, Masahiro [National Cancer Center, Kashiwa, Chiba (Japan). Hospital East

    1998-04-01

    Some small hepatocellular carcinoma (HCC) lesions show as tumor stains by dynamic CT, but cannot be detected by ultrasonography. Percutaneous ethanol injection (PEI) is effective for treating small HCC lesions, but lack of adequate visualization of some lesions can limit its use. In this study, interventional radiographic, CT-fluoroscopically-guided PEI was performed as a new method for treating small HCC lesions that were difficult to detect by ultrasonography. Interventional radiographic, CT-fluoroscopically-guided PEI was performed on 11 patients (12 lesions) with HCC lesions measuring 2 cm or less in diameter. A thin needle was introduced into each tumor under CT-fluoroscopic guidance, with injection of contrast medium into the dominant hepatic artery. While lesions were observed using CT-fluoroscopy with the arteriogram, absolute ethanol was injected into the tumors. The ethanol injection rate and volume were monitored by observation of loss of tumor staining during real-time CT angiography. Needle introduction was successful in all 12 lesions, and disappearance of tumor staining was immediately observed on CT images after ethanol injection. Complications noted after treatment were local abdominal pain in all 11 patients, a slight fever in 9 patients, pneumothorax, right pleural effusion, and ascites, each in 1 patient. No other serious complications were observed. Interventional radiographic, CT-fluoroscopically-guided PEI is effective in the treatment of small HCC lesions, which are difficult to show by ultrasonography and treat by conventional PEI. (author)

  9. Role of fluoroscopic guided self expandable metallic stents in the management of malignant esophageal strictures

    Directory of Open Access Journals (Sweden)

    Mohamed Shaker

    2016-09-01

    Conclusion: Fluoroscopic guided esophageal stenting is a highly effective and safe method for palliating dysphagia in patients with obstructing esophageal cancer with significant clinical improvement.

  10. Video dosimetry: evaluation of X-radiation dose by video fluoroscopic image

    International Nuclear Information System (INIS)

    Nova, Joao Luiz Leocadio da; Lopes, Ricardo Tadeu

    1996-01-01

    A new methodology to evaluate the entrance surface dose on patients under radiodiagnosis is presented. A phantom is used in video fluoroscopic procedures in on line video signal system. The images are obtained from a Siemens Polymat 50 and are digitalized. The results show that the entrance surface dose can be obtained in real time from video imaging

  11. Performance Evaluations of Four MAF-Based PLL Algorithms for Grid-Synchronization of Three-Phase Grid-Connected PWM Inverters and DGs

    DEFF Research Database (Denmark)

    Han, Yang; Luo, Mingyu; Chen, Changqing

    2016-01-01

    The moving average filter (MAF) is widely utilized to improve the disturbance rejection capability of the phase-locked loops (PLLs), which is of vital significance for the grid-integration and stable operation of power electronic converters to the electric power systems. However, the open-loop ba...

  12. Spontaneous coronary artery dissection: complete angiographic resolution without stenting

    Directory of Open Access Journals (Sweden)

    Alexandre Abizaid

    2007-09-01

    Full Text Available A case of spontaneous coronary artery dissection in a 49-year-oldwoman is presented. She did not present the classical cardiovascular riskfactors. Etiology and treatment are discussed. She underwent primarypercutaneous coronary intervention of the left anterior descendingartery with no stenting and had complete angiographic resolution.

  13. Mesenteric Castleman's disease: ultrasound, computed tomography and angiographic appearance

    International Nuclear Information System (INIS)

    Malara, F.A.; Price, D.; Fabiny

    2000-01-01

    The localized form of Castleman's disease is rare, and a mesenteric location is particularly unusual. A case of an asymptomatic young woman having the hyaline vascular type is presented and the ultrasound, computed tomography (CT) and angiographic features of the condition are demonstrated. Copyright (1999) Blackwell Science Pty Ltd

  14. Ebselen treatment prevents islet apoptosis, maintains intranuclear Pdx-1 and MafA levels, and preserves β-cell mass and function in ZDF rats.

    Science.gov (United States)

    Mahadevan, Jana; Parazzoli, Susan; Oseid, Elizabeth; Hertzel, Ann V; Bernlohr, David A; Vallerie, Sara N; Liu, Chang-qin; Lopez, Melissa; Harmon, Jamie S; Robertson, R Paul

    2013-10-01

    We reported earlier that β-cell-specific overexpression of glutathione peroxidase (GPx)-1 significantly ameliorated hyperglycemia in diabetic db/db mice and prevented glucotoxicity-induced deterioration of β-cell mass and function. We have now ascertained whether early treatment of Zucker diabetic fatty (ZDF) rats with ebselen, an oral GPx mimetic, will prevent β-cell deterioration. No other antihyperglycemic treatment was given. Ebselen ameliorated fasting hyperglycemia, sustained nonfasting insulin levels, lowered nonfasting glucose levels, and lowered HbA1c levels with no effects on body weight. Ebselen doubled β-cell mass, prevented apoptosis, prevented expression of oxidative stress markers, and enhanced intranuclear localization of pancreatic and duodenal homeobox (Pdx)-1 and v-maf musculoaponeurotic fibrosarcoma oncogene family, protein A (MafA), two critical insulin transcription factors. Minimal β-cell replication was observed in both groups. These findings indicate that prevention of oxidative stress is the mechanism whereby ebselen prevents apoptosis and preserves intranuclear Pdx-1 and MafA, which, in turn, is a likely explanation for the beneficial effects of ebselen on β-cell mass and function. Since ebselen is an oral antioxidant currently used in clinical trials, it is a novel therapeutic candidate to ameliorate fasting hyperglycemia and further deterioration of β-cell mass and function in humans undergoing the onset of type 2 diabetes.

  15. SU-F-I-76: Fluoroscopic X-Ray Beam Profiles for Spectra Incorporating Copper Filtration

    Energy Technology Data Exchange (ETDEWEB)

    Wunderle, K [Cleveland Clinic Foundation, Cleveland, OH (United States); Wayne State University School of Medicine, Detroit, MI (United States); Godley, A; Shen, Z; Dong, F [Cleveland Clinic Foundation, Cleveland, OH (United States); Rakowski, J [Wayne State University School of Medicine, Detroit, MI (United States)

    2016-06-15

    Purpose: The purpose of this investigation is to characterize and quantify X-ray beam profiles for fluoroscopic x-ray beam spectra incorporating spectral (copper) filtration. Methods: A PTW (Freiburg, Germany) type 60016 silicon diode detector and PTW MP3 water tank were used to measure X-ray beam profiles for 60, 80, 100 and 120 kVp x-ray beams at five different copper filtration thicknesses ranging from 0–0.9 mm at 22 and 42 cm fields of view and depths of 1, 5, and 10 cm in both the anode-cathode axis (inplane) and cross-plane directions. All measurements were acquired on a Siemens (Erlangen, Germany) Artis ZeeGo fluoroscope inverted from the typical orientation providing an x-ray beam originating from above the water surface with the water level set at 60 cm from the focal spot. Results: X-ray beam profiles for beam spectra without copper filtration compared well to previously published data by Fetterly et al. [Med Phys, 28, 205 (2001)]. Our data collection benefited from the geometric orientation of the fluoroscope, providing a beam perpendicular to the tank water surface, rather than through a thin side wall as did the previously mentioned study. Profiles for beams with copper filtration were obtained which have not been previously investigated and published. Beam profiles in the anode-cathode axis near the surface and at lower x-ray energy exhibited substantial heel effect, which became less pronounced at greater depth. At higher energy with copper filtration in the beam, the dose falloff out-of-field became less pronounced, as would be anticipated given higher scatter photon energy. Conclusion: The x-ray beam profile data for the fluoroscopic x-ray beams incorporating copper filtration are intended for use as reference data for estimating doses to organs or soft tissue, including fetal dose, involving similar beam qualities or for comparison with mathematical models.

  16. Transrectal Drainage of Deep Pelvic Abscesses Using a Combined Transrectal Sonographic and Fluoroscopic Guidance

    International Nuclear Information System (INIS)

    Jeong, Kyung Soon; Lee, Eun Jung; Ko, Ji Ho; Joh, Young Duk; Jung, Gyoo Sik

    2005-01-01

    To evaluate the feasibility and clinical efficacy of transrectal drainage of a deep pelvic abscess using combined transrectal sonographic and fluoroscopic guidance. From March 1995 and August 2004, 17 patients (9 men; 8 women; mean age, 39 years) suffering from pelvic pain, fever and leukocytosis were enrolled in this retrospective study. Ultrasound (US) or computed tomography (CT), which was obtained prior to the procedure, showed pelvic fluid collections that were deemed unapproachable by the percutaneous trans abdominal routes. Transrectal drainage of the pelvic abscess was performed under combined transrectal sonographic and fluoroscopic guidance. The causes of the deep pelvic abscess were postoperative complications (n=7), complications associated with radiation (n=3) and chemotherapy (n=1) as well as unknown causes (n=6). A 7.5-MHz end-firing transrectal US probe with a needle biopsy guide attachment was advanced into the rectum. Once the abscess was identified, a needle was advanced via the biopsy guide and the abscess was punctured. Under US guidance, either a 0.018'or 0.035' guide wire was passed through the needle in the abscess. Under fluoroscopic guidance, the tract was dilated to the appropriate diameter with sequential fascial dilators, and a catheter was placed over the guide wire within the abscess. Clinical success of drainage was determined by a combination closure of the cavity on the follow up images and diminished leukocytosis. The technical and clinical success rate, complications, and patient's discomfort were analyzed. Drainage was technically successful in all patients and there were no serious complications. Surgery was eventually performed in two cases due to fistular formation with the rectum and leakage of the anastomosis site. The procedure was well tolerated in all but one patient who complained of discomfort while the catheter was inserted . The catheter did not interfere with defecation and there was no incidence of catheter

  17. Evaluation of occurring complications after flow diverter treatment of elastase-induced aneurysm in rabbits using micro-CT and MRI at 9.4 T

    Energy Technology Data Exchange (ETDEWEB)

    Simgen, Andreas; Ley, Desiree; Muehl-Benninghaus, Ruben; Koerner, Heiko; Reith, Wolfgang; Yilmaz, Umut [Saarland University Hospital, Department of Neuroradiology, Homburg, Saar (Germany); Roth, Christian [Clinic Bremen-Mitte, Department of Neuroradiology, Bremen (Germany); Cattaneo, Giorgio Franco Maria [Acandis GmbH, Pforzheim (Germany); Mueller, Andreas [Saarland University Hospital, Department of Experimental Surgery, Homburg, Saar (Germany); Kim, Yoo-Jin [Saarland University Hospital, Department of Pathology, Homburg, Saar (Germany); Scheller, Bruno [Saarland University Hospital, Department of Cardiology, Homburg, Saar (Germany)

    2016-10-15

    Flow diverters are increasingly being used to treat intracranial aneurysms. This study evaluates occurring complications of flow-diverting devices in the treatment of experimental aneurysms, involving the use of micro-CT and small animal MRI at 9.4 T, in correlation to angiographic and histological findings. We previously published two preclinical studies, in which we assessed two different flow diverters in the treatment of elastase-induced aneurysms. Devices have been implanted across the aneurysm neck as well as in the abdominal aorta. From these studies, a total of 65 devices (prototype FD (n = 30) and Derivo embolization device (n = 35)) additionally underwent micro-CT and MRI after angiographic follow-up and before being histologically examined. The different architectures of both devices were precisely comparable due to high-resolution micro-CT imaging. Micro-CT revealed wire fractures in nine cases (30 %) only with the prototype FD. In three cases (10 %), severe wire fractures correlated with an in-stent stenosis due to intimal hyperplasia. Other complications, like distal stent occlusions and post-stent stenosis, were seen in both groups and verified with both imaging techniques. Osseous metaplasia were correlated to calcifications seen with micro-CT. MRI enabled visualization of the position of the implanted devices relative to the aneurysm and revealed incomplete aneurysm neck coverage with the prototype FD in two cases (6.7 %). Micro-CT and 9.4-T MRI are valid to discover and understand occurring complications of flow diverters in the preclinical phase and can serve as evaluation tools to minimize complication rates of endovascular devices in the future. (orig.)

  18. SU-F-I-75: Half-Value Layer Thicknesses and Homogeneity Coefficients for Fluoroscopic X-Ray Beam Spectra Incorporating Spectral Filtration

    Energy Technology Data Exchange (ETDEWEB)

    Wunderle, K [Cleveland Clinic Foundation, Cleveland, OH (United States); Wayne State University School of Medicine, Detroit, MI (United States); Godley, A; Shen, Z; Dong, F [Cleveland Clinic Foundation, Cleveland, OH (United States); Rakowski, J [Wayne State University School of Medicine, Detroit, MI (United States)

    2016-06-15

    Purpose: The purpose of this investigation is to quantify various first half-value-layers (HVLs), second HVLs and homogeneity coefficients (HCs) for a state-of-the-art fluoroscope utilizing spectral (copper) filtration. Methods: A Radcal (Monrovia, Ca) AccuPro dosimeter with a 10×6-6 calibrated ionization chamber was used to measure air kerma for radiographic x-ray exposures made on a Siemens (Erlangen, Germany) Artis ZeeGo fluoroscope operated in the service mode. The ionization chamber was centered in the x-ray beam at 72 cm from the focal spot with a source-to-image-distance of 120 cm. The collimators were introduced to limit the x-ray field to approximately 5 cm × 5 cm at the ionization chamber plane. Type-1100 aluminum filters, in 0.5 mm increments, were used to determine the HVL. Two HVL calculation methods were used, log-linear interpolation and Lambert-W interpolation as described by Mathieu [Med Phys, 38(8), 4546 (2011)]. Multiple measurements were made at 60, 80, 100, 120 kVp at spectral filtration thicknesses of 0, 0.1, 0.3, 0.6 and 0.9 mm. Results: First HVL, second HVL, and HCs are presented for the fluoroscopic x-ray beam spectra indicated above, with nearly identical results from the two interpolation methods. Accuracy of the set kVp was also determined and deviated less than 2%. First HVLs for fluoroscopic x-ray beam spectra without spectral filtration determined in our study were 7%–16% greater than previously published data by Fetterly et al. [Med Phys, 28, 205 (2001)]. However, the FDA minimum HVL requirements changed since that publication, requiring larger HVLs as of 2006. Additionally, x-ray tube and generator architecture have substantially changed over the last 15 years providing different beam spectra. Conclusion: X-ray beam quality characteristics for state-of-the-art fluoroscopes with spectral filtration have not been published. This study provides reference data which will be useful for defining beam qualities encountered on

  19. C-arm cone beam computed tomography needle path overlay for fluoroscopic guided vertebroplasty.

    Science.gov (United States)

    Tam, Alda L; Mohamed, Ashraf; Pfister, Marcus; Chinndurai, Ponraj; Rohm, Esther; Hall, Andrew F; Wallace, Michael J

    2010-05-01

    Retrospective review. To report our early clinical experience using C-arm cone beam computed tomography (C-arm CBCT) with fluoroscopic overlay for needle guidance during vertebroplasty. C-arm CBCT is advanced three-dimensional (3-D) imaging technology that is currently available on state-of-the-art flat panel based angiography systems. The imaging information provided by C-arm CBCT allows for the acquisition and reconstruction of "CT-like" images in flat panel based angiography/interventional suites. As part of the evolution of this technology, enhancements allowing the overlay of cross-sectional imaging information can now be integrated with real time fluoroscopy. We report our early clinical experience with C-arm CBCT with fluoroscopic overlay for needle guidance during vertebroplasty. This is a retrospective review of 10 consecutive oncology patients who underwent vertebroplasty of 13 vertebral levels using C-arm CBCT with fluoroscopic overlay for needle guidance from November 2007 to December 2008. Procedural data including vertebral level, approach (transpedicular vs. extrapedicular), access (bilateral vs. unilateral) and complications were recorded. Technical success with the overlay technology was assessed based on accuracy which consisted of 4 measured parameters: distance from target to needle tip, distance from planned path to needle tip, distance from midline to needle tip, and distance from the anterior 1/3 of the vertebral body to needle tip. Success within each parameter required that the distance between the needle tip and parameter being evaluated be no more than 5 mm on multiplanar CBCT or fluoroscopy. Imaging data for 12 vertebral levels was available for review. All vertebral levels were treated using unilateral access and 9 levels were treated with an extrapedicular approach. Technical success rates were 92% for both distance from planned path and distance from midline to final needle tip, 100% when distance from needle tip to the anterior 1

  20. Angiographic diagnosis of hemorrhage tumours of the small intestine

    International Nuclear Information System (INIS)

    Vadon, G.; Ehngloner, L.; Petri, K.

    1980-01-01

    2 angiographic investigations in small intestine tumors, accompanied with hemorrhage are considered. Conclusion is made that the most suitable moment for estimation of small intestine hemorrhage, according to the proper and literature data, is selective angiography. Wide application of the technique for preoperative detection of gastro-inestinal hemorrhage is recommended

  1. Angiographic features of 26 children with Takayasu's arteritis

    International Nuclear Information System (INIS)

    McCulloch, M.; Goddard, E.; Sinclair, P.; Andronikou, S.; Mandelstam, S.; Beningfield, S.J.; Lawrenson, J.; Millar, A.J.W.

    2003-01-01

    Background: Takayasu's arteritis (TA) is a chronic idiopathic inflammatory disease affecting primarily the aorta, its proximal branches and the pulmonary arteries Objectives: To retrospectively review the angiograms of children with TA so as to describe the patterns of vascular involvement. Patients and methods: Twenty-six children with TA who differed from most other studies in that almost all of them presented with hypertension, reflecting the incidence of abdominal aortic and renal artery involvement. Results: The most consistent finding was stenosis of the aorta. Marginal irregularity/undulation of the aorta was also a useful angiographic diagnostic feature in subtle disease. The incidence of aneurysms was high compared to other studies and both fusiform and saccular aneurysms were encountered. Percutaneous transluminal angioplasty (PTA) was successful in all eight patients in whom it was performed. MRI, CT angiography and US are discussed as less invasive imaging alternatives. TA is a significant cause of renovascular hypertension in children in South Africa where there is a high incidence of tuberculous infection. Knowledge of the angiographic features and pattern of aortic involvement is essential for diagnosis and initiation of early and appropriate treatment, including PTA. (orig.)

  2. 28 CFR 552.13 - X-ray, major instrument, fluoroscope, or surgical intrusion.

    Science.gov (United States)

    2010-07-01

    ... 28 Judicial Administration 2 2010-07-01 2010-07-01 false X-ray, major instrument, fluoroscope, or... INSTITUTIONAL MANAGEMENT CUSTODY Searches of Housing Units, Inmates, and Inmate Work Areas § 552.13 X-ray, major... reasons only, with the inmate's consent. (b) The institution physician may authorize use of an X-ray for...

  3. Comparison of intravascular ultrasound and angiographic assessement of coronary reference segment size in patients with type 2 diabetes mellitus

    DEFF Research Database (Denmark)

    Jensen, Lisette Okkels; Thayssen, Per; Mintz, Gary S

    2008-01-01

    During percutaneous coronary intervention, the reference segment is assessed angiographically. This report described the discrepancy between angiographic and intravascular ultrasound (IVUS) assessment of reference segment size in patients with type 2 diabetes mellitus. Preintervention IVUS was used...... to study 62 de novo lesions in 41 patients with type 2 diabetes mellitus. The lesion site was the image slice with the smallest lumen cross-sectional area (CSA). The proximal and distal reference segments were the most normal-looking segments within 5 mm proximal and distal to the lesion. Plaque burden...... was measured as plaque CSA/external elastic membrane (EEM) CSA. Using IVUS, the reference lumen diameter was 2.80 +/- 0.42 mm and the reference EEM diameter was 4.17 +/- 0.56 mm. The angiographic reference diameter was 2.63 +/- 0.36 mm. Mean difference between the IVUS EEM diameter and angiographic reference...

  4. CT and angiographic appearances of hepatocellular carcinoma partially fed by right inferior phrenic artery

    Energy Technology Data Exchange (ETDEWEB)

    Ohtomo, Kuni; Furui, Shigeru; Yoshikawa, Hiroki; Yashiro, Naofumi; Araki, Tsutomu [Tokyo Univ. (Japan). Faculty of Medicine

    1983-04-01

    CT and angiographic appearances of 8 hepatocellular carcinomas which were partially fed by right inferior phrenic artery were discussed. CT demonstrated tumor fully occupied posterior segment of right hepatic lobe in 6 cases which were composed of 3 solitary massive, 2 massive nodular and 1 confluent massive angiographically. In the other 2 cases, CT showed encapsulated tumor in posterior inferior portion of posterior segment protruded from the liver. In 6 out of these 8 cases, tumor vessels and tumor stain were chiefly derived from posterior branch of right inferior phrenic artery.

  5. CT and angiographic appearances of hepatocellular carcinoma partially feeded by right inferior phrenic artery

    International Nuclear Information System (INIS)

    Ohtomo, Kuni; Furui, Shigeru; Yoshikawa, Hiroki; Yashiro, Naofumi; Araki, Tsutomu

    1983-01-01

    CT and angiographic appearances of 8 hepatocellular carcinomas which were partially feeded by right inferior phrenic artery were discussed. CT demonstrated tumor fully occupied posterior segment of right hepatic lobe in 6 cases which were composed of 3 solitary massive, 2 massive nodular and 1 confluent massive angiographically. In the other 2 cases, CT showed encapsulated tumor in posterior inferior portion of posterior segment protruded from the liver. In 6 out of these 8 cases, tumor vessels and tumor stain were chiefly derived from posterior branch of right inferior phrenic artery. (author)

  6. An engineering development of fluoroscopic X-ray medical equipment based-on fluorescent screen

    International Nuclear Information System (INIS)

    Ferry Suyatno; I Putu Susila; Djoko Sukmono

    2011-01-01

    Fluoroscopic x-ray medical equipment uses fluorescent screen to capture structural image of organs. Unlike conventional x-ray equipment which uses film, in the fluoroscopic x-ray, the resulting image is visualized on the fluorescent screen and directly observed by physicians in the patients' rooms. In this study, we developed an image capture system that transforms the image on the fluorescent screen into digital data, which is then transferred to computer for visualization and further processing. By using this system, the observation of the resulting image can be done on a computer that is placed in the control room. The image can also be stored easily and at low cost compared to conventional film. The experiment shows that the system could be used to capture image of the object. However, its quality needs to be improved. In the future, the system will be modified and tested with different types of cameras to obtain better results. (author)

  7. The pretzel sign: angiographic pattern of tortuous intra-aneurysmal blood flow in a giant serpentine aneurysm.

    LENUS (Irish Health Repository)

    Fanning, N F

    2012-02-03

    Giant serpentine aneurysms (GSAs) form a specific subgroup of giant cerebral aneurysms that have pathognomonic angiographic features. We report the angiographic findings of a GSA demonstrating a striking convoluted dynamic flow pattern, which we have called the \\'pretzel sign\\'. The aneurysm was successfully treated by permanent occlusion of the parent vessel using a detachable balloon. GSAs should be identified prior to treatment in view of their particular management requirements.

  8. The value of regional wall motion abnormalities on gated mycardiac perfusion imaging in perfusion imaging in predicting angiographic stenoses of coronary artery

    International Nuclear Information System (INIS)

    Yao Lixin; Liu Binbin

    2007-01-01

    Objective: To determine the possible level of angiographic stenoses of coronary artery at which reversible regional wall motion abnormalities (RWMA) are present on 99m Tc-sestamibi ( 99m Tc-MIBI)-gated myocardial perfusion imaging (MPI). Methods: ninty patients undergoing coronary angiography MPI within two weeks were recruited. A five grades and nine segments marking system was introduced to assess the RWMA and thickening of left ventricles. Results: The sensitivity of reversible RWMA for detecting ≥75% angiographic stenoses was 64%,with a specificity of 95% and positive predictive value of 97%. The presence of reversible RWMA was able to stratify patients with severe angiographic stenoses of 75% or more from those less than 75% with high positive predictive value. A good correlation was noted between the presence of reversible RWMA and the coronary artery jeopardy score. Multivariate analysis showed that the post-stress RWMA and reversible RWMA scores and positive dipyridamole-stress exercise electrocardiogram(ECG) were significant predictors of angiographic severity. Conclusions: Reversible RWMA, as shown by dipyridamole stress 99m Tc-MIBI MPI, is a significant predictor of angiographic disease with very high specificity and adds incremental value to MPI for the assessment of angiographic severity. (authors)

  9. Foreign body extraction from soft tissue by using CT and fluoroscopic guidance: a new technique

    Energy Technology Data Exchange (ETDEWEB)

    Amoretti, Nicolas; Marcy, Pierre-Yves; Lesbats-Jacquot, Virginie; Fonquerne, Marie-Eve; Maratos, Yvonne [Centre Hospitalier Universitaire de Nice, Radiology Department, Nice (France); Hauger, Olivier [Hopital Pellegrin, Unite d' Imagerie Osteo-articulaire, CHU de Bordeaux (France); Hovorka, Istvan; Boileau, Pascal [Centre Hopitalier Universitaire de Nice, Orthopaedic Department, Nice (France)

    2010-01-15

    We report on a new minimally invasive technique for the retrieval of a surgical pin fragment after accidental migration into the soft tissue of the shoulder in two patients. The technique is performed under local anaesthesia and uses combined CT and fluoroscopic guidance. The materials used were simple, combining a bone biopsy needle and an endoscopy clamp. Pin displacement was confirmed under fluoroscopic guidance and the clamp was used to withdraw the pin to the cutaneous entry point under CT (step-by-step) guidance. The CT slices provide perfect visualisation of the vascular or nervous structures as well as perfect positioning of the extremity of the trocar relative to the material to be removed. This intervention avoids a second surgical intervention with a longer incision and avoided repeated general anaesthesia. (orig.)

  10. Feasibility and Safety of Transradial Arterial Approach for Simultaneous Right and Left Vertebral Artery Angiographic Studies and Stenting

    International Nuclear Information System (INIS)

    Yip, H.-K.; Youssef, Ali A.; Chang, W.-N.; Lu, C.-H.; Yang, C.-H.; Chen, S.-M.; Wu, C.-J.

    2007-01-01

    Objectives. This study investigated whether the transradial artery (TRA) approach using a 6-French (F) Kimny guiding catheter for right vertebral artery (VA) angiographic study and stenting is safe and effective for patients with significant VA stenosis. Background. The TRA approach is commonly performed worldwide for both diagnostic cardiac catheterization and catheter-based coronary intervention. However, to our knowledge, the safety and feasibility of left and right VA angiographic study and stenting, in the same procedure, using the TRA approach for patients with brain ischemia have not been reported. Methods. The study included 24 consecutive patients (22 male, 2 female; age, 63-78 years). Indications for VA angiographic study and stenting were (1) prior stroke or symptoms related to vertebrobasilar ischemia and (2) an asymptomatic but vertebral angiographic finding of severe stenosis (>70%). A combination of the ipsilateral and retrograde-engagement technique, which involved a looping 6-F Kimny guiding catheter, was utilized for VA angiographic study. For VA stenting, an ipsilateral TRA approach with either a Kimny guiding catheter or a left internal mammary artery guiding catheter was utilized in 22 patients and retrograde-engagement technique in 2 patients. Results. A technically successful procedure was achieved in all patients, including left VA stenting in 15 patients and right VA stenting in 9 patients. The mean time for stenting (from engagement to stent deployment) was 12.7 min. There were no vascular complications or mortality. However, one patient suffered from a transient ischemic attack that resolved within 3 h. Conclusion. We conclude that TRA access for both VA angiographic study and VA stenting is safe and effective, and provides a simple and useful clinical tool for patients unsuited for femoral arterial access

  11. The zero-wall puncture: a novel angiographic puncture technique with substantial benefits

    International Nuclear Information System (INIS)

    Leswick, D.A.; Szkup, P.; Stoneham, G.W.

    2005-01-01

    Medical education can be busy, exhausting, and stressful, with potential adverse effects on trainees' physical and mental health. Radiology residency is no exception. In addition to increased daily workload and study requirements, Canadian radiology residents are performing a diverse and increasing number of emergent diagnostic examinations after hours. In an attempt to improve resident self-worth and efficiency during angiographic rotations, we investigated the effects of a novel angiographic puncture procedure on various resident lifestyle indexes. Standard techniques for accessing the femoral artery are either the single-wall puncture or double-wall puncture (Seldinger technique). Both of these techniques are widely known and practiced. Following procedure completion, hemostasis must be achieved at the puncture site. This has traditionally required manual compression at the puncture site, which may require 15 to 20 minutes. At our institution the standard policy is that 'whoever makes the puncture, compresses the groin,' also known as 'you broke it, you fix it'. This has prompted our industrious resident complement to develop a novel, previously undescribed, angiographic puncture technique known as the 'zero-wall puncture technique.' Preliminary unpublished results from our institution show that when residents employ the zero-wall puncture technique the attending staff radiologist subsequently both performs the puncture and compresses the groin at the end of the procedure. We investigated the effect of zero-wall puncture on various resident lifestyle indexes. (author)

  12. Fluoroscopically guided fallopian tube recanalization with a simplified set of instruments

    International Nuclear Information System (INIS)

    Schmitz-Rode, T.; Guenther, R.W.; Neulen, J.

    2004-01-01

    Purpose: Fluoroscopically guided transcervical fallopian tube recanalization is recognized as an important step in the workup of female infertility. In the present study, a simplified set of recanalization instruments was tested. Materials and Methods: Forty-two women with infertility and sonographically confirmed or suspected uni- or bilateral tubal occlusion were examined. After vaginal placement of a plastic speculum and fixation of a tenaculum, a 4F glide catheter with a 0.89 mm glidewire was advanced transcervically. After documentation of tubal occlusion by hysterosalpingography, the uterotubal junction was catheterized with the same instruments. Under fluoroscopic guidance, the glidewire was negotiated beyond the intramural portion of the tube. Selective salpingography documented the outcome of the recanalization. Results: Hysterosalpingography confirmed tubal occlusions in 26 of 42 patients (in 12 cases unilateral and in 14 cases bilateral). Fallopian tube recanalization was successful in 23 of 26 patients (technical success rate of 88%). The resulting fertility rate was 30% (7/23), without any ectopic pregnancy. Complications such as tubal perforation, infection, or bleeding did not occur. Tubal catheterization was straightforward and smooth in 17/23 cases. For a hyperflexed uterus (6/23), a curved tip of the catheter was helpful in tubal probing. (orig.)

  13. Relationship between Angiographic Results and Morphology in Sidewall Intracranial Aneurysms after Stent-Assisted Coil Embolization.

    Science.gov (United States)

    Nii, Kouhei; Aikawa, Hiroshi; Tsutsumi, Masanori; Eto, Ayumu; Iko, Minoru; Sakamoto, Kimiya; Inoue, Ritsuro; Mitsutake, Takafumi; Hanada, Hayatsura; Kazekawa, Kiyoshi

    2016-03-01

    Stent-assisted coil embolization (SACE) is used to address wide-necked or complex aneurysms. However, as they may recanalize after SACE, predictors of recanalization are needed. We investigated the relationship between follow-up angiographic results and the morphology of sidewall (SW) aneurysms in patients treated by SACE. Between September 2010 and September 2014, we performed 80 SACE procedures for SW intracranial aneurysms. Angiographic findings, obtained immediately after the procedure, 3-6 months thereafter, and when aneurysmal recanalization was suspected on MR angiogram scan, were recorded. Morphologically, the SW aneurysms were classified as "outside" (OS) and "partially inside" (PI) based on the curve of the axes of the proximal or distal parent artery with respect to the aneurysmal neck. Follow-up angiographic studies on OS- and PI SW aneurysms were compared. On the initial angiograms, we classified 42 aneurysms as OS and 38 as PI. Immediately after SACE, there was no significant difference in the angiographic findings on OS and PI aneurysms. However, on follow-up angiograms, there was a significant difference in the rate of spontaneous improvement (4 of 42 [OS] versus 21 of 38 [PI], P = .001). We performed additional coil embolization to treat 3 recanalized OS aneurysms. SW aneurysms classified morphologically as PI tended to occlude progressively even after incomplete occlusion by SACE. In contrast, aneurysms classified as OS must be observed carefully after SACE. Copyright © 2016 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  14. Comparison of MR and fluoroscopic mucous fistulography in the pre-operative evaluation of infants with anorectal malformation: a pilot study

    Energy Technology Data Exchange (ETDEWEB)

    Alves, Jose C.G.; Lotz, Jan W.; Pitcher, Richard D. [Stellenbosch University, Division of Radiodiagnosis, Department of Medical Imaging and Clinical Oncology, Tygerberg Academic Hospital, Cape Town (South Africa); Sidler, Daniel [Stellenbosch University, Division of Pediatric Surgery, Department of Surgical Sciences, Tygerberg Academic Hospital, Cape Town (South Africa)

    2013-08-15

    Anorectal malformations are often associated with rectal pouch fistulas. Surgical correction requires accurate evaluation of the presence and position of such fistulas. Fluoroscopy is currently the chosen modality for the detection of fistulas. The role of MRI is unexplored. To compare the diagnostic accuracy of MR versus fluoroscopic fistulography in the pre-operative evaluation of infants with anorectal malformation. We conducted a pilot study of infants requiring defunctioning colostomy for initial management of anorectal malformation. Dynamic sagittal steady-state free-precession MRI of the pelvis was acquired during introduction of saline into the mucous fistulas. Findings were compared among MR fistulography, fluoroscopic fistulography and intraoperative inspection. Eight children were included. Median age at fistulography was 15 weeks, inter-quartile range 13-20 weeks; all were boys. There was full agreement among MR fistulography, fluoroscopic fistulography and surgical findings. The pilot data suggest that MR fistulography is promising in the pre-operative evaluation of children with anorectal malformation. (orig.)

  15. IMPORTANCE OF KNOWING ANGIOGRAPHIC CHARACTERISTICS OF THE TENSOR FASCIAE LATAE VASCULAR STALK

    Directory of Open Access Journals (Sweden)

    Sladjana Ugrenovic

    2006-07-01

    Full Text Available Atherosclerosis is the most important and most common type of arteriosclerosis and is a general term for several diseases in which the artery wall becomes thicker and less elastic. The most common location of atherosclerosis occurrence is arteries of lower extremities, while arteries of upper extremities as well as visceral arteries are far less and far rarely affected with this degenerative process.The most frequent ones are occlusive changes on bifurcation of the abdominal aorta (aortoiliac obstructive atherosclerosis “Morbus Leriche”, trunk of the femoral artery and initial part of the popliteal artery (femoropopliteal obstructive atherosclerosis.Angiography, as additional method in medicine, gives the most precise insight into anatomical changes on blood vessels. With intention of estimating the possibility of using a slice (lobe part of the tensor fasciae latae (m. TFL in plastic and reconstructive surgery, we have analyzed 50 angiograms of femoral artery. The first group included Morbus Leriche patients (25 analyzed angiographics, while the second one comprised patients with femoropopliteal segment disease (also 25 analyzed angiographics. With angiographic analysis of the lateral femoral circumflex artery (LCFA and its branch, which is dominant in vascularisation of m. TFL slice, we discovered that the diameter of its source, as well as of its branches, is bigger in cases of femoropopliteal segment disease. Then, the reduction of the source diameter of LCFA and its branches, caused by vascular disease, leads to decreased blood supply of m. TFL, diminishing its quality and limiting its usage in surgery.In Morbus Leriche cases, m. TFL slice cannot be used in plastic and reconstructive surgery, its quality being decreased, due to poor vascularization. In femoropopliteal segment disease cases, thanks to normal blood supply, m. TFL slice can be widely used for reconstructions or covering of defects, especially in inguinal region, which is

  16. Surgical Management of Juvenile Nasopharyngeal Angiofibroma Without Angiographic Embolization

    Directory of Open Access Journals (Sweden)

    Raja Ahmad

    2008-10-01

    Full Text Available Juvenile nasopharyngeal angiofibroma (JNA is a rare benign neoplasm that occurs almost exclusively in the nasopharynx of adolescent males. Surgery remains the primary treatment of choice. JNA has always presented a management challenge to surgeons because of its vascular nature, site of occurrence, and local tissue destruction. The surgical approaches are either standard open method which include external or intraoral incisions, or the recent advanced approach, i.e. via using the endonasal endoscope. It is widely accepted that the use of preoperative angiographic embolization reduces the occurrence of intraoperative bleeding and facilitates tumour removal. However, angiographic embolization is not available at all centres. The purpose of this article is to present our experience with five patients diagnosed with JNA who were resected without embolization, using various surgical approaches. Two tumours were removed via endonasal endoscopic surgery. None of the tumours were embolized prior to surgery. We highlight the preoperative evaluation of tumour extent, using both computed tomography (CT and magnetic resonance angiography, and the importance of temporary clamping of the external carotid artery intraoperatively. Our results suggest that the latter procedure is a safe and effective means of facilitating surgery and reducing intraoperative bleeding.

  17. Radiotherapy verification film for estimating cumulative entrance skin exposure for fluoroscopic examinations

    International Nuclear Information System (INIS)

    Geise, R.A.; Ansel, H.J.

    1990-01-01

    Measurement of skin entrance exposures during fluoroscopic procedures is complicated by the use of automatic exposure control devices and the presence of contrast media. Due to variability in positioning spot films from patient to patient, standard dosimeters, such as thermoluminescent, cannot be properly placed on the skin prior to examination. Prepackaged film of the type used for portal verification in radiation therapy held next to the patient's skin in a specially modified patient examination gown was found to be useful for determining the entrance skin exposure from both fluoroscopy and spot films during air contrast barium enema exams. The usable sensitivity range of this film has been found satisfactory for exposure measurements at exposures and kVps typically used for gastrointestinal fluoroscopic procedures. Errors in exposure estimates due to changes in film speed and contrast with kVp are less than 5% for the range of kVps used. Errors from variations in beam quality due to the adjacency of scattering material are approximately 5%. Entrance exposures determined with film agreed with those determined from TLD measurements to within 21%, with an average difference of 9%

  18. Intractable Postpartum Bleeding: A Comparison of the Retrospective Analysis of Angiographic Findings and Transcatheter Arterial Embolization According to Delivery Pattern

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, Eun Jung; Kim, Young Hwan; Kim, Si Hyung; Choi, Jin Soo; Park, Jun Cheol; Kwon, Sang Hun; Jo, Chi Heum; Cha, Soon Do [Keimyung University College of Medicine, Daegu (Korea, Republic of)

    2008-12-15

    We evaluated the technical aspect and efficacy of transcatheter arterial embolization (TAE) in cases of intractable postpartum bleeding by comparing the angiographic findings women patients according to their delivery pattern. Between July of 2003 and March of 2008, 55 female patients were enrolled in this study. Of the 55 patients, 36 underwent a vaginal delivery (group 1), whereas 19 underwent a cesarean section delivery (group 2). We retrospectively evaluated the angiographic findings and the embolization technique between groups, using a Pearson Chi-Square test. Medical records and telephone interview findings were also reviewed to evaluate the efficacy of TAE and the outcome of fertility. Significantly greater positive angiographic findings were found in group 2 (63.2%) relative to group 1 (30.6%). For positive angiographic findings, except for AVM, the embolization was performed using coil or glue with gelfoam. For the negative angiographic findings or AVM, the gelfoam was the only embolic agent used. In all patients except for one, bleeding stopped after embolization. Major complications occurred in 2 patients only, and included uterine synechia and perforation. All patients except for one recovered after menstruation. In total, four patients became pregnant and one patient delivered a healthy infant. Positive angiographic findings requiring embolization with coil or glue, as well as gelfoam, were more commonly encountered in group 2 than in group 1. Based on the outcome of the study group, TAE is a safe and effective treatment for intractable postpartum bleeding and is also useful for preserving fertility.

  19. Intractable Postpartum Bleeding: A Comparison of the Retrospective Analysis of Angiographic Findings and Transcatheter Arterial Embolization According to Delivery Pattern

    International Nuclear Information System (INIS)

    Ahn, Eun Jung; Kim, Young Hwan; Kim, Si Hyung; Choi, Jin Soo; Park, Jun Cheol; Kwon, Sang Hun; Jo, Chi Heum; Cha, Soon Do

    2008-01-01

    We evaluated the technical aspect and efficacy of transcatheter arterial embolization (TAE) in cases of intractable postpartum bleeding by comparing the angiographic findings women patients according to their delivery pattern. Between July of 2003 and March of 2008, 55 female patients were enrolled in this study. Of the 55 patients, 36 underwent a vaginal delivery (group 1), whereas 19 underwent a cesarean section delivery (group 2). We retrospectively evaluated the angiographic findings and the embolization technique between groups, using a Pearson Chi-Square test. Medical records and telephone interview findings were also reviewed to evaluate the efficacy of TAE and the outcome of fertility. Significantly greater positive angiographic findings were found in group 2 (63.2%) relative to group 1 (30.6%). For positive angiographic findings, except for AVM, the embolization was performed using coil or glue with gelfoam. For the negative angiographic findings or AVM, the gelfoam was the only embolic agent used. In all patients except for one, bleeding stopped after embolization. Major complications occurred in 2 patients only, and included uterine synechia and perforation. All patients except for one recovered after menstruation. In total, four patients became pregnant and one patient delivered a healthy infant. Positive angiographic findings requiring embolization with coil or glue, as well as gelfoam, were more commonly encountered in group 2 than in group 1. Based on the outcome of the study group, TAE is a safe and effective treatment for intractable postpartum bleeding and is also useful for preserving fertility

  20. Usefulness of angiographic embolization endoscopic metallic clip placement in patient with non-variceal upper gastrointestinal bleeding

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Min Jae; Hwang, Cheol Mog; Kim, Ho Jun; Cho, Young Jun; Bae, Seok Hwan [Dept. of Radiology, Konyang University Hospital, Daejeon (Korea, Republic of); Shin, Byung Seok; Ohm, Joon Young [Dept. of Radiology, Chungnam National University College of Medicine, Daejeon (Korea, Republic of); Kang, Chae Hoon [Dept. of Radiology, Inje University College of Medicine, Pusan Paik Hospital, Busan (Korea, Republic of)

    2013-08-15

    The aim of this study is to assess the usefulness of angiographic embolization after endoscopic metallic clip placement around the edge of non-variceal upper gastrointestinal bleeding ulcers. We have chosen 41 patients (mean age, 65.2 years) with acute bleeding ulcers (22 gastric ulcers, 16 duodenal ulcers, 3 malignant ulcers) between January 2010 and December 2012. We inserted metallic clips during the routine endoscopic treatments of the bleeding ulcers. Subsequent transcatheter arterial embolization was performed within 2 hours. We analyzed the angiographic positive rates, angiographic success rates and clinical success rates. Among the 41 patients during the angiography, 19 patients (46%) demonstrated active bleeding points. Both groups underwent embolization using microcoils, N-butyl-cyano-acrylate (NBCA), microcoils with NBCA or gelfoam particle. There are no statistically significant differences between these two groups according to which embolic materials are being used. The bleeding was initially stopped in all patients, except the two who experienced technical failures. Seven patients experienced repeated episodes of bleeding within two weeks. Among them, 4 patients were successful re-embolized. Another 3 patients underwent gastrectomy. Overall, clinical success was achieved in 36 of 41 (87.8%) patients. The endoscopic metallic clip placement was helpful to locate the correct target vessels for the angiographic embolization. In conclusion, this technique reduced re-bleeding rates, especially in patients who do not show active bleeding points.

  1. Usefulness of angiographic embolization endoscopic metallic clip placement in patient with non-variceal upper gastrointestinal bleeding

    International Nuclear Information System (INIS)

    Yoon, Min Jae; Hwang, Cheol Mog; Kim, Ho Jun; Cho, Young Jun; Bae, Seok Hwan; Shin, Byung Seok; Ohm, Joon Young; Kang, Chae Hoon

    2013-01-01

    The aim of this study is to assess the usefulness of angiographic embolization after endoscopic metallic clip placement around the edge of non-variceal upper gastrointestinal bleeding ulcers. We have chosen 41 patients (mean age, 65.2 years) with acute bleeding ulcers (22 gastric ulcers, 16 duodenal ulcers, 3 malignant ulcers) between January 2010 and December 2012. We inserted metallic clips during the routine endoscopic treatments of the bleeding ulcers. Subsequent transcatheter arterial embolization was performed within 2 hours. We analyzed the angiographic positive rates, angiographic success rates and clinical success rates. Among the 41 patients during the angiography, 19 patients (46%) demonstrated active bleeding points. Both groups underwent embolization using microcoils, N-butyl-cyano-acrylate (NBCA), microcoils with NBCA or gelfoam particle. There are no statistically significant differences between these two groups according to which embolic materials are being used. The bleeding was initially stopped in all patients, except the two who experienced technical failures. Seven patients experienced repeated episodes of bleeding within two weeks. Among them, 4 patients were successful re-embolized. Another 3 patients underwent gastrectomy. Overall, clinical success was achieved in 36 of 41 (87.8%) patients. The endoscopic metallic clip placement was helpful to locate the correct target vessels for the angiographic embolization. In conclusion, this technique reduced re-bleeding rates, especially in patients who do not show active bleeding points.

  2. Development of a method to calculate organ doses for the upper gastrointestinal fluoroscopic examination

    International Nuclear Information System (INIS)

    Suleiman, O.H.

    1989-01-01

    A method was developed to quantitatively measure the upper gastrointestinal fluoroscopic examination in order to calculate organ doses. The dynamic examination was approximated with a set of discrete x-ray fields. Once the examination was segmented into discrete x-ray fields appropriate organ dose tables were generated using an existing computer program for organ dose calculations. This, along with knowledge of the radiation exposures associated with each of the fields, enabled the calculation of organ doses for the entire dynamic examination. The protocol involves videotaping the examination while fluoroscopic technique factors, tube current and tube potential, are simultaneously recorded on the audio tracks of the videotape. Subsequent analysis allows the dynamic examination to be segmented into a series of discrete x-ray fields uniquely defined by field size, projection, and anatomical region. The anatomical regions associated with the upper gastrointestinal examination were observed to be the upper, middle, and lower esophagus, the gastroesophageal junction, the stomach, and the duodenum

  3. Persistent sciatic artery: clinical, embryologic, and angiographic features

    International Nuclear Information System (INIS)

    Mandell, V.S.; Jaques, P.F.; Delaney, D.J.; Oberheu, V.

    1985-01-01

    The persistent sciatic artery is a rare but interesting and clinically pertinent vascular anomaly that may present as a buttock aneurysm or as an ischemic or embolic disease. Its correct angiographic diagnosis depends on recognition of an abnormally large internal iliac artery, appropriate injection and adequate timing to fill and follow flow into the large vessel, and recognition and differentiation of the tapering superficial femoral artery from routine occlusive disease so that an accurate picture of lower leg runoff is provided

  4. Automatic change detection in RapidEye data using the combined MAD and kernel MAF methods

    DEFF Research Database (Denmark)

    Nielsen, Allan Aasbjerg; Hecheltjen, Antje; Thonfeld, Frank

    2010-01-01

    The IR-MAD components show changes for a large part of the entire subset. Especially phenological changes in the agricultural fields surrounding the open pit are predominant. As opposed to this, kMAF components focus more on changes in the open-cast mine (and changes due to the two clouds...... and their shadows, not visible in the zoom). Ground data were available from bucket-wheel excavators on the extraction side (to the northwest in the open pit) in terms of elevation data for both dates. No ground data were available for changes due to backfill (southeastern part of the open pit) or changes due...

  5. Diagnostic accuracy of unenhanced, contrast-enhanced perfusion and angiographic MRI sequences for pulmonary embolism diagnosis: results of independent sequence readings

    Energy Technology Data Exchange (ETDEWEB)

    Revel, Marie Pierre [Hopital Europeen Georges Pompidou, APHP, Departments of Radiology, Paris (France); Universite Paris Descartes Sorbonne Paris Cite, Paris (France); Hotel-Dieu, Service de Radiologie, Paris (France); Sanchez, Olivier; Meyer, Guy [Hopital Europeen Georges Pompidou, APHP, Respiratory and intensive care and, Paris (France); Universite Paris Descartes Sorbonne Paris Cite, Paris (France); INSERM Unite 765, Paris (France); Lefort, Catherine; Couchon, Sophie; Hernigou, Anne; Frija, Guy [Hopital Europeen Georges Pompidou, APHP, Departments of Radiology, Paris (France); Niarra, Ralph [Hopital Europeen Georges Pompidou, APHP, Clinical Epidemiology, Paris (France); Universite Paris Descartes Sorbonne Paris Cite, Paris (France); Chatellier, Gilles [Hopital Europeen Georges Pompidou, APHP, Clinical Epidemiology, Paris (France); Universite Paris Descartes Sorbonne Paris Cite, Paris (France); INSERM CIC-EC E4, Paris (France)

    2013-09-15

    To independently evaluate unenhanced, contrast-enhanced perfusion and angiographic MR sequences for pulmonary embolism (PE) diagnosis. Prospective investigation, including 274 patients who underwent perfusion, unenhanced 2D steady-state-free-precession (SSFP) and contrast-enhanced 3D angiographic MR sequences on a 1.5-T unit, in addition to CTA (CT angiography). Two independent readers evaluated each sequence independently in random order. Sensitivity, specificity, predictive values and inter-reader agreement were calculated for each sequence, excluding sequences judged inconclusive. Sensitivity was also calculated according to PE location. Contrast-enhanced angiographic sequences showed the highest sensitivity (82.9 and 89.7 %, reader 1 and reader 2, respectively), specificity (98.5 and 100 %) and agreement (kappa value 0.77). Unenhanced angiographic sequences, although less sensitive overall (68.7 and 76.4 %), were sensitive for the detection of proximal PE (92.7 and 100 %) and showed high specificity (96.1 and 99.1 %) and good agreement (kappa value 0.62). Perfusion sequences showed lower sensitivity (75.0 and 79.3 %), specificity (84.8 and 89.7 %) and agreement (kappa value 0.51), and a negative predictive value of 84.8 % at best. Compared with contrast-enhanced angiographic sequences, unenhanced sequences demonstrate lower sensitivity, except for proximal PE, but high specificity and agreement. The negative predictive value of perfusion sequences was insufficient to safely rule out PE. (orig.)

  6. The value of regional wall motion abnormalities on 99Tcm-MIBI gated cardiac SPECT in predicting angiographic stenoses of coronary artery

    International Nuclear Information System (INIS)

    Li Dianfu; Huang Jun; Zhu Tiebing; Wang Liansheng; Yang Zhijian; Feng Jianlin; Li Jianhua; Chen Jianwei; Chang Guojun

    2004-01-01

    Objective: To determine the magnitude of angiographic stenoses of coronary artery in reversible regional wall motion abnormalities (RWMA) present in exercise stress 99 Tc m -methoxyisobutylisonitrile (MIBI) gated SPECT myocardial perfusion imaging (MPI). Methods: One hundred and sixteen patients undergoing coronary angiography two weeks before and after the exercise stress 99 Tc m -MIBI gated SPECT MPI. Images were acquired 15 to 20 min after stress. A five grades and twenty segments marking system was introduced to assess the RWMA and thickening of left ventricles. Results: The sensitivity of reversible RWMA for detecting ≥75% angiographic stenoses was 65%, with a specificity of 97%. Reversible RWMA has a high positive predictive value (98%) for stratification between severe angiographic stenoses of 75% and non-severe stenoses (less than 75%). Multivariate analysis showed that the post-stress wall motion (SSSWM), exercise wall motion differentiation value (SDSWM) and summed stress score (SSS) were the independent risk factor of coronary artery jeopardy score. Conclusions: Reversible RWMA, as shown by exercise stress 99 Tc m -MIBI gated SPECT MPI, is a significant predictor of angiographic disease with very high specificity and positive predictive values. Exercise reversible RWMA can rise the assessment value of angiographic severity in MPI

  7. Effectiveness of Fluoroscopic and US - Guided Percutaneous Catheter Drainage for Iliopsoas Abscess through the Anterolateral Transabdominal Approach

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Ho Cheol; Shin, Tae Beom; Park, Mee Jung; Kim, Ji Eun; Choi, Hye Young; Bae, Kyung Soo; Choi, Dae Seob; Na, Jae Boem; Jeong, Seong Hoon [Gyeongsang National University Hospital, College of Medicine, Jinju (Korea, Republic of)

    2011-02-15

    We evaluated the effectiveness of performing fluoroscopic and ultrasonography guided percutaneous catheter drainage (PCD) through the anterolateral transabdominal approach for treating iliopsoas abscess. From January 2008 to December 2009, fluoroscopic and US-guided PCD through the anterolateral transabdominal approach was performed on sixteen iliopsoas abscesses of fourteen patients (7 males and 7 females; mean age: 63 years; age range: 30-87 years). Six abscesses were on the right side and ten abscesses were on the left side. The location of the abscesses were the psoas muscle (n=7), the iliacus muscle (n=7) and the iliopsoas muscle (n=2). All the procedures were performed under fluoroscopy and US guidance in the angiography room. The clinical findings before and after the procedure, the duration of catheter insertion and the procedure-related complications were evaluated. 15 out of the 16 iliopsoas abscesses were effectively treated. The duration of catheter insertion was 5- 27 days (mean: 14.6) days. No patient had significant complications during or after drainage. One patient died of uncontrolled diabetes complications and shock on the 9th day after percutaneous catheter drainage. One recurrence was noted 5 months after removal of the catheter. This patient underwent aspiration and antibiotic treatment for this lesion and the patient improved. Fluoroscopic and US-guided PCD for iliopsoas abscess through the anterolateral transabdominal approach is an effective and safe procedure

  8. MR angiographic and parenchymal evaluation of cerebral infaraction in sickle cell anemia

    International Nuclear Information System (INIS)

    Masaryk, T.J.; Masaryk, A.M.; Ross, J.S.; Modic, M.T.; Wiznitzer, M.; Berman, B.

    1989-01-01

    Cerebral infarction is an important complication of sickle cell anemia, believed to be related to large-vessel stenoses/occlusion and/or capillary/venous sickling resulting in thrombosis. Identification of these complications (especially large-vessel arterial disease) is important in selecting patients for transfusion therapy. The purpose of this study was to determine the suitability of combined three-dimensional Fourier transform time-of-flight MR angiographic and parenchymal T2-weighted spin-echo examinations for evaluation of central nervous system (CNS) complications of sickle cell anemia. Seven patients (age range, 5-14 years) were evaluated. Five had documented strokes while two had symptoms resembling those of transient ischemic attack. The preliminary data indicate that combined MR angiographic and parenchymal studies are capable of identifying those patients with sickle cell anemia complicated by large-vessel CNS occlusive disease and cerebral infarction and can be used as a noninvasive guide to therapy

  9. Angiographic Evaluation of Carotid Artery Grafting with Prefabricated Small-Diameter, Small-Intestinal Submucosa Grafts in Sheep

    International Nuclear Information System (INIS)

    Pavcnik, Dusan; Obermiller, Josef; Uchida, Barry T.; Van Alstine, William; Edwards, James M.; Landry, Gregory J.; Kaufman, John A.; Keller, Frederick S.; Roesch, Josef

    2009-01-01

    The purpose of this study was to report the longitudinal angiographic evaluation of prefabricated lyophilized small-intestinal submucosa (SIS) grafts placed in ovine carotid arteries and to demonstrate a variety of complications that developed. A total of 24 grafts, 10 cm long and 6 mm in diameter, were placed surgically as interposition grafts. Graft patency at 1 week was evaluated by Doppler ultrasound, and angiography was used for follow-up at 1 month and at 3 to 4 months. A 90% patency rate was found at 1 week, 65% at 1 month, and 30% at 3 to 4 months. On the patent grafts, angiography demonstrated a variety of changes, such as anastomotic stenoses, graft diffuse dilations and dissections, and aneurysm formation. These findings have not been previously demonstrated angiographically by other investigators reporting results with small-diameter vessel grafts made from fresh small-intestinal submucosa (SIS). The complications found were partially related to the graft construction from four SIS layers. Detailed longitudinal angiographic study should become an essential part of any future evaluation of small-vessel SIS grafting.

  10. Fluoroscopically guided percutaneous jejunostomy: outcomes in 25 consecutive patients

    International Nuclear Information System (INIS)

    Yang, Z.Q.; Shin, J.H.; Song, H.-Y.; Kwon, J.H.; Kim, J.-W.; Kim, K.R.; Kim, J.-H.

    2007-01-01

    Aim: To assess the feasibility and safety of fluoroscopically guided percutaneous jejunostomy. Material and methods: Between May 1999 and August 2006 percutaneous jejunostomy was attempted in 25 patients. A 5 F vascular catheter (n = 20) or a 7.5 F multifunctional coil catheter (n = 5) was used to insufflate the jejunum. The distended jejunum was punctured using a 17 G needle (n = 19) or a 21 G Chiba needle (n = 6) with the inserted catheter as a target. A 12 or 14 F loop feeding tube was inserted after serial dilations. The technical success, complications, 30-day mortality, and in-dwelling period of the feeding tube placement were evaluated. Results: The technical success rate was 92% (23/25). Technical failures (n = 2) resulted from the inability to insufflate the jejunum secondary to failure to pass the catheter through a malignant stricture at the oesophagojejunostomy site and thus subsequent puncture of the undistended jejunum failed, or failure to introduce the Neff catheter into the jejunum. Pericatheter leakage with pneumoperitoneum was a complication in three patients (12%) and was treated conservatively. The 30-day mortality was 13% (3/23); however, there was no evidence that these deaths were attributed to the procedure. Except for four patients who were lost to follow-up and two failed cases, 15 of the 19 jejunostomy catheters were removed because of patient death (n = 12) or completion of treatment (n = 3), with a mean and median in-dwelling period of 231 and 87 days, respectively. Conclusions: Fluoroscopically guided percutaneous jejunostomy is a feasible procedure with a high technical success and a low complication rate. In addition to a 17 G needle, a 21 G needle can safely be used to puncture the jejunum

  11. Exposition of the operator's eye lens and efficacy of radiation shielding in fluoroscopically guided interventions

    International Nuclear Information System (INIS)

    Galster, M.; Adamus, R.; Guhl, C.; Uder, M.

    2013-01-01

    Purpose: Efficacy of radiation protection tools for the eye lens dose of the radiologist in fluoroscopic interventions. Materials and Methods: A patient phantom was exposed using a fluoroscopic system. Dose measurements were made at the eye location of the radiologist using an ionization chamber. The setting followed typical fluoroscopic interventions. The reduction of scattered radiation by the equipment-mounted shielding (undercouch drapes and overcouch top) was evaluated. The ceiling-suspended lead acrylic glass screen was tested in scattered radiation generated by a slab phantom. The protective properties of different lead glass goggles and lead acrylic visors were evaluated by thermoluminescence measurements on a head phantom in the primary beam. Results: The exposition of the lens of about 110 to 550 μSv during radiologic interventions is only slightly reduced by the undercouch drapes. Applying the top in addition to the drapes reduces the lens dose by a factor of 2 for PA projections. In 25 LAO the dose is reduced by a factor between 1.2 and 5. The highest doses were measured for AP angulations furthermore the efficacy of the equipment-mounted shielding is minimal. The ceiling-suspended lead screen reduced scatter by a factor of about 30. The lead glass goggles and visors reduced the lens dose up to a factor of 8 to 10. Depending on the specific design, the tested models are less effective especially for radiation from lateral with cranial angulation of the beam. Occasionally the visors even caused an increase of dose. Conclusion: The exposition of the eye lens can be kept below the new occupational limit recommended by the ICRP if the radiation shielding equipment is used consistently. (orig.)

  12. Clinical-pathological-angiographic correlations following transluminal atherectomy

    International Nuclear Information System (INIS)

    Althaus, S.J.; Maynar, M.; Reyes, R.; Pulido-Duque, J.M.; Casal, G.; Hunter, D.W.; Castaneda-Zuniga, W.R.; Amplatz, K.

    1989-01-01

    Following percutaneous atherectomy, arterial and catheter diameter relationships were correlated with angiographic and ankle-arm index results. There was a greater amount of tissue removed, improved luminal reconstitution, and ankle-arm index in lesions where the catheter and arterial diameters were equal or within 0.5 mm. Excluding lesions requiring angioplasty, 77% of our lesions had less than 30% residual stenosis; including lesions requiring concomitant angioplasty, the initial overall patency was 93%, with a 1-year patency rate of 92.5%. This study indicates that adequate matching of the atherectomy catheter diameter to the arterial diameter is necessary to optimize tissue removal and clinical results

  13. Clinical results of stereotactic heavy-charged-particle radiosurgery for intracranial angiographically occult vascular malformations

    International Nuclear Information System (INIS)

    Levy, R.P.; Fabrikant, J.I.; Phillips, M.H.; Frankel, K.A.; Steinberg, G.K.; Marks, M.P.; DeLaPaz, R.L.; Chuang, F.Y.S.; Lyman, J.T.

    1989-12-01

    Angiographically occult vascular malformations (AOVMs) of the brain have been recognized for many years to cause neurologic morbidity and mortality. They generally become symptomatic due to intracranial hemorrhage, focal mass effect, seizures or headaches. The true incidence of AOVMs is unknown, but autopsy studies suggest that they are more common than high-flow angiographically demonstrable arteriovenous malformations (AVMs). We have developed stereotactic heavy-charged-particle Bragg peak radiosurgery for the treatment of inoperable intracranial vascular malformations, using the helium ion beams at the Lawrence Berkeley Laboratory 184-inch Synchrocyclotron and Bevatron. This report describes the protocol for patient selection, radiosurgical treatment planning method, clinical and neuroradiologic results and complications encountered, and discusses the strengths and limitations of the method. 10 refs., 1 fig

  14. Clinical results of stereotactic heavy-charged-particle radiosurgery for intracranial angiographically occult vascular malformations

    Energy Technology Data Exchange (ETDEWEB)

    Levy, R.P.; Fabrikant, J.I.; Phillips, M.H.; Frankel, K.A.; Steinberg, G.K.; Marks, M.P.; DeLaPaz, R.L.; Chuang, F.Y.S.; Lyman, J.T.

    1989-12-01

    Angiographically occult vascular malformations (AOVMs) of the brain have been recognized for many years to cause neurologic morbidity and mortality. They generally become symptomatic due to intracranial hemorrhage, focal mass effect, seizures or headaches. The true incidence of AOVMs is unknown, but autopsy studies suggest that they are more common than high-flow angiographically demonstrable arteriovenous malformations (AVMs). We have developed stereotactic heavy-charged-particle Bragg peak radiosurgery for the treatment of inoperable intracranial vascular malformations, using the helium ion beams at the Lawrence Berkeley Laboratory 184-inch Synchrocyclotron and Bevatron. This report describes the protocol for patient selection, radiosurgical treatment planning method, clinical and neuroradiologic results and complications encountered, and discusses the strengths and limitations of the method. 10 refs., 1 fig.

  15. High-speed rotary atherectomy under fluoroscopic and angioscopic guidance

    International Nuclear Information System (INIS)

    Deutsch, L.S.; Ahn, S.S.; Yeatman, L.A.; Marcus, D.R.; Auth, D.P.; Moore, W.S.

    1988-01-01

    This paper describes thirteen stenotic arteries treated by high-speed rotary abrasive burr atherectomy performed in the operating room under fluoroscopic-angioscopic control by a multidisciplinary team consisting of a vascular surgeon, an interventional radiologist, and an interventional cardiologist. Incrementally sized atherectomy burrs were used in each patient (1.75-4.0 mm in diameter). Rotary artherectomy was successful in 11 of 13 arteries ranging from 1 to 40 cm (median, 5 cm) with stenoses ranging from 50% to 99% (median, 90%), which improved to less than 30% in all 11 successfully atherectomized segments. Two early posttreatment failures (intimal dissection, burr shaft disruption), two posttreatment thromboses (unrelated to atherectomy), and two late failures (restenosis) occurred

  16. Comparative quantitative angiographic analysis of directional coronary atherectomy and balloon coronary angioplasty

    NARCIS (Netherlands)

    V.A.W.M. Umans (Victor); K.J. Beatt (Kevin); B.J.W.M. Rensing (Benno); W.R.M. Hermans (Walter); P.J. de Feyter (Pim); P.W.J.C. Serruys (Patrick)

    1991-01-01

    markdownabstract__Abstract__ An attempt to assess the “utility” of directional atherectomy was made using a new quantitative angiographic index. This index can be subdivided into an initial gain component and a restenosis component. The initial gain index is the ratio between the gain in diameter

  17. Hemodynamic disturbances in cerebral ischemia; Correlation between positron emission tomographic and angiographic findings

    Energy Technology Data Exchange (ETDEWEB)

    Tenjin, Hiroshi; Ueda, Satoshi; Mizukawa, Norihiko; Imahori, Yoshio; Hino, Akihiko; Ohmori, Yoshio [Kyoto Prefectural Univ. of Medicine (Japan); Nakahashi, Hisamitsu

    1993-04-01

    Proper treatment of ischemic stroke requires better understanding of cerebral hemodynamic changes. The hemodynamic changes associated with ischemia were measured using positron emission tomography and related to angiographic findings in the subacute and chronic stages of 17 ischemia patients who showed symptoms of main trunk stenosis of the internal carotid artery system. The hemodynamic factors, cerebral blood flow, cerebral blood volume, cerebral metabolic rate for oxygen, oxygen extraction fraction, and flow/volume ratio, were measured in regions of interest determined from the angiographic stenosis (over 50%) and compared in each stage. The cerebral blood flow and flow/volume ratio in the territory downstream of the main trunk stenosis and cerebral metabolic rate for oxygen in the whole cortex were decreased in the subacute stage. In the chronic stage, cerebral blood flow and flow/volume ratio decreased mainly in borderzone areas. (author).

  18. Evaluation of methods to produce an image library for automatic patient model localization for dose mapping during fluoroscopically guided procedures

    Science.gov (United States)

    Kilian-Meneghin, Josh; Xiong, Z.; Rudin, S.; Oines, A.; Bednarek, D. R.

    2017-03-01

    The purpose of this work is to evaluate methods for producing a library of 2D-radiographic images to be correlated to clinical images obtained during a fluoroscopically-guided procedure for automated patient-model localization. The localization algorithm will be used to improve the accuracy of the skin-dose map superimposed on the 3D patient- model of the real-time Dose-Tracking-System (DTS). For the library, 2D images were generated from CT datasets of the SK-150 anthropomorphic phantom using two methods: Schmid's 3D-visualization tool and Plastimatch's digitally-reconstructed-radiograph (DRR) code. Those images, as well as a standard 2D-radiographic image, were correlated to a 2D-fluoroscopic image of a phantom, which represented the clinical-fluoroscopic image, using the Corr2 function in Matlab. The Corr2 function takes two images and outputs the relative correlation between them, which is fed into the localization algorithm. Higher correlation means better alignment of the 3D patient-model with the patient image. In this instance, it was determined that the localization algorithm will succeed when Corr2 returns a correlation of at least 50%. The 3D-visualization tool images returned 55-80% correlation relative to the fluoroscopic-image, which was comparable to the correlation for the radiograph. The DRR images returned 61-90% correlation, again comparable to the radiograph. Both methods prove to be sufficient for the localization algorithm and can be produced quickly; however, the DRR method produces more accurate grey-levels. Using the DRR code, a library at varying angles can be produced for the localization algorithm.

  19. Initial Experience with Computed Tomography and Fluoroscopically Guided Placement of Push-Type Gastrostomy Tubes Using a Rupture-Free Balloon Catheter

    International Nuclear Information System (INIS)

    Fujita, Takeshi; Tanabe, Masahiro; Yamatogi, Shigenari; Shimizu, Kensaku; Matsunaga, Naofumi

    2011-01-01

    The purpose of this study was to evaluate the safety and feasibility of percutaneous radiologic gastrostomy placement of push-type gastrostomy tubes using a rupture-free balloon (RFB) catheter under computed tomography (CT) and fluoroscopic guidance. A total of 35 patients (23 men and 12 women; age range 57–93 years [mean 71.7]) underwent percutaneous CT and fluoroscopically guided gastrostomy placement of a push-type gastrostomy tube using an RFB catheter between April 2005 and July 2008. Technical success, procedure duration, and complications were analyzed. Percutaneous radiologic gastrostomy placement was considered technically successful in all patients. The median procedure time was 39 ± 13 (SD) min (range 24–78). The average follow-up time interval was 103 days (range 7–812). No major complications related to the procedure were encountered. No tubes failed because of blockage, and neither tube dislodgement nor intraperitoneal leakage occurred during the follow-up period. The investigators conclude that percutaneous CT and fluoroscopically guided gastrostomy placement with push-type tubes using an RFB catheter is a safe and effective means of gastric feeding when performed by radiologists.

  20. Leaded eyeglasses substantially reduce radiation exposure of the surgeon's eyes during acquisition of typical fluoroscopic views of the hip and pelvis.

    Science.gov (United States)

    Burns, Sean; Thornton, Raymond; Dauer, Lawrence T; Quinn, Brian; Miodownik, Daniel; Hak, David J

    2013-07-17

    Despite recommendations to do so, few orthopaedists wear leaded glasses when performing operative fluoroscopy. Radiation exposure to the ocular lens causes cataracts, and regulatory limits for maximum annual occupational exposure to the eye continue to be revised downward. Using anthropomorphic patient and surgeon phantoms, radiation dose at the surgeon phantom's lens was measured with and without leaded glasses during fluoroscopic acquisition of sixteen common pelvic and hip views. The magnitude of lens dose reduction from leaded glasses was calculated by dividing the unprotected dose by the dose measured behind leaded glasses. On average, the use of leaded glasses reduced radiation to the surgeon phantom's eye by tenfold, a 90% reduction in dose. However, there was widespread variation in the amount of radiation that reached the phantom surgeon's eye among the various radiographic projections we studied. Without leaded glasses, the dose measured at the surgeon's lens varied more than 250-fold among these sixteen different views. In addition to protecting the surgeon's eye from the deleterious effects of radiation, the use of leaded glasses could permit an orthopaedist to perform fluoroscopic views on up to ten times more patients before reaching the annual dose limit of 20 mSv of radiation to the eye recommended by the International Commission on Radiological Protection. Personal safety and adherence to limits of occupational radiation exposure should compel orthopaedists to wear leaded glasses for fluoroscopic procedures if other protective barriers are not in use. Leaded glasses are a powerful tool for reducing the orthopaedic surgeon's lens exposure to radiation during acquisition of common intraoperative fluoroscopic views.

  1. Mercury in air and plant specimens in herbaria: A pilot study at the MAF Herbarium in Madrid (Spain)

    International Nuclear Information System (INIS)

    Oyarzun, R.; Higueras, P.; Esbri, J.M.; Pizarro, J.

    2007-01-01

    We present data from a study of mercury concentrations in air and plant specimens from the MAF Herbarium in Madrid (Spain). Hg (gas) emissions from old plant collections treated with mercuric chloride (HgCl 2 ) in herbaria may pose a health risk for staff working in installations of this type. This is an issue not yet properly addressed. Plants that underwent insecticide treatment with HgCl 2 at the MAF Herbarium until the mid 1970s have persistent high concentrations of Hg in the range 1093-11,967 μg g -1 , whereas untreated specimens are in the range of 1.2-4.3 μg g -1 . The first group induces high concentrations of Hg (gas) in the main herbarium room, with seasonal variations of 404-727 ng m -3 (late winter) and 748-7797 ng m -3 (early summer) (baseline for Hg: 8 ng m -3 ). A test survey at another herbarium in Madrid showed even higher concentrations of Hg (gas) above 40,000 ng m -3 . The World Health Organization guidelines for chronic exposure to Hg (gas) are estimated at a maximum of 1000 ng m -3 . While staff was aware of the existence of HgCl 2 treated plants (the plant specimen sheets are labelled as 'poisoned'), they had no knowledge of the presence of high Hg (gas) concentrations in the buildings, a situation that may be relatively common in herbaria

  2. Mercury in air and plant specimens in herbaria: A pilot study at the MAF Herbarium in Madrid (Spain)

    Energy Technology Data Exchange (ETDEWEB)

    Oyarzun, R. [Departamento de Cristalografia y Mineralogia, Facultad de Ciencias Geologicas, Universidad Complutense, 28040 Madrid (Spain)], E-mail: oyarzun@geo.ucm.es; Higueras, P.; Esbri, J.M. [Departamento de Ingenieria Geologica y Minera, Escuela Universitaria Politecnica de Almaden, Universidad de Castilla-La Mancha, Plaza M. Meca 1, 13400 Almaden (Spain); Pizarro, J. [Departamento de Biologia Vegetal II, Facultad de Farmacia, Universidad Complutense, 28040 Madrid (Spain)

    2007-11-15

    We present data from a study of mercury concentrations in air and plant specimens from the MAF Herbarium in Madrid (Spain). Hg (gas) emissions from old plant collections treated with mercuric chloride (HgCl{sub 2}) in herbaria may pose a health risk for staff working in installations of this type. This is an issue not yet properly addressed. Plants that underwent insecticide treatment with HgCl{sub 2} at the MAF Herbarium until the mid 1970s have persistent high concentrations of Hg in the range 1093-11,967 {mu}g g{sup -1}, whereas untreated specimens are in the range of 1.2-4.3 {mu}g g{sup -1}. The first group induces high concentrations of Hg (gas) in the main herbarium room, with seasonal variations of 404-727 ng m{sup -3} (late winter) and 748-7797 ng m{sup -3} (early summer) (baseline for Hg: 8 ng m{sup -3}). A test survey at another herbarium in Madrid showed even higher concentrations of Hg (gas) above 40,000 ng m{sup -3}. The World Health Organization guidelines for chronic exposure to Hg (gas) are estimated at a maximum of 1000 ng m{sup -3}. While staff was aware of the existence of HgCl{sub 2} treated plants (the plant specimen sheets are labelled as 'poisoned'), they had no knowledge of the presence of high Hg (gas) concentrations in the buildings, a situation that may be relatively common in herbaria.

  3. The predictive value of angiographic results for the outcome of percutaneous transluminal angioplasty in stenosed femoral bypass grafts

    International Nuclear Information System (INIS)

    Spijkerboer, Anje M.; Beek, Frederik J. A.; Graaf, Yolanda van der; Eikelboom, Bert C.; Mali, Willem P. T. M.

    1997-01-01

    Purpose. To assess the predictive value of immediate angiographic results after percutaneous transluminal angioplasty (PTA) for stenoses in femoral bypass grafts using duplex ultrasound (DUS) criteria. Methods. A 1-year follow-up with DUS was performed in 38 patients with 50 stenoses in 41 grafts, treated with PTA for a graft stenosis. The indication for PTA according to DUS criteria was a severe stenosis in 43 lesions, and a moderate stenosis in 7 lesions. In the moderate stenosis group 3 patients showed claudication and 1 patient had a nonhealing ulcer. For the purposes of statistical evaluation, primary patency was considered present if the graft was not occluded. The graft was considered to have failed when it was found to be occluded on DUS, or when secondary interventions (surgery, repeat PTA) were performed. Results. After 1 year the cumulative primary patency rate was 44$ [95% confidence interval (CI) 27.8-59.8]. Stenoses with initially good angiographic results after PTA (<30% residual stenosis) were 2.9 times more likely to be patent at 1 year than stenoses with initially poor or moderate angiographic results (hazard ratio 2.9, 95% CI 1.3-6.4,p=0.007). Conclusion. A poor or moderate angiographic result immediately following PTA was prognostic for poor long-term results and may indicate a requirement for earlier surgical intervention

  4. Risk factors and short-term outcome in patients with angiographically negative subarachnoid hemorrhage

    DEFF Research Database (Denmark)

    Dalbjerg, Sara Maria; Larsen, Carl Christian; Romner, Bertil

    2013-01-01

    The objective of this study was to identify prognostic factors for clinical outcome in patients with non-traumatic, angiographically negative subarachnoid hemorrhage. Furthermore, the aim was to investigate if patients on anticoagulant therapy may have a more unfavorable outcome than patients...

  5. Lung tumor tracking in fluoroscopic video based on optical flow

    International Nuclear Information System (INIS)

    Xu Qianyi; Hamilton, Russell J.; Schowengerdt, Robert A.; Alexander, Brian; Jiang, Steve B.

    2008-01-01

    Respiratory gating and tumor tracking for dynamic multileaf collimator delivery require accurate and real-time localization of the lung tumor position during treatment. Deriving tumor position from external surrogates such as abdominal surface motion may have large uncertainties due to the intra- and interfraction variations of the correlation between the external surrogates and internal tumor motion. Implanted fiducial markers can be used to track tumors fluoroscopically in real time with sufficient accuracy. However, it may not be a practical procedure when implanting fiducials bronchoscopically. In this work, a method is presented to track the lung tumor mass or relevant anatomic features projected in fluoroscopic images without implanted fiducial markers based on an optical flow algorithm. The algorithm generates the centroid position of the tracked target and ignores shape changes of the tumor mass shadow. The tracking starts with a segmented tumor projection in an initial image frame. Then, the optical flow between this and all incoming frames acquired during treatment delivery is computed as initial estimations of tumor centroid displacements. The tumor contour in the initial frame is transferred to the incoming frames based on the average of the motion vectors, and its positions in the incoming frames are determined by fine-tuning the contour positions using a template matching algorithm with a small search range. The tracking results were validated by comparing with clinician determined contours on each frame. The position difference in 95% of the frames was found to be less than 1.4 pixels (∼0.7 mm) in the best case and 2.8 pixels (∼1.4 mm) in the worst case for the five patients studied.

  6. Angiographic evaluation of the effect of intra-arterial milrinone therapy in patients with vasospasm from aneurysmal subarachnoid hemorrhage.

    Science.gov (United States)

    Shankar, Jai Jai Shiva; dos Santos, Marlise P; Deus-Silva, Leonardo; Lum, Cheemun

    2011-02-01

    Several methods have been used to treat cerebral vasospasm, which is a major cause of morbidity and mortality in patients with aneurysmal subarachnoid hemorrhage (SAH). Here, we examined the effectiveness and safety of intra-arterial injection of milrinone for the treatment of vasospasm. Consecutive patients with angiographically confirmed vasospasm received intra-arterial milrinone between January 2006 and December 2007. The improvement in diameter of vessel (in millimeters) following treatment was assessed by paired t test for statistical significance. The angiographic improvement of supraclinoid internal carotid artery, M1 segment of middle cerebral artery, and A1 and A2 segment of anterior cerebral artery was compared with the modified Rankin score of the patients at discharge. A total of 15 milrinone treatments were performed in 14 patients (11 females and 3 males) with mean age of 52.7 years (31-68 years). There was significant angiographic improvement after milrinone therapy (p milrinone was a safe and effective treatment of cerebral vasospasm following aneurysmal SAH.

  7. Differential Clinical Outcomes Between Angiographic Complete Versus Incomplete Coronary Revascularization, According to the Presence of Chronic Kidney Disease in the Drug-Eluting Stent Era.

    Science.gov (United States)

    Kim, Jihoon; Lee, Joo Myung; Choi, Ki Hong; Rhee, Tae-Min; Hwang, Doyeon; Park, Jonghanne; Ahn, Chul; Park, Taek Kyu; Yang, Jeong Hoon; Song, Young Bin; Choi, Jin-Ho; Hahn, Joo-Yong; Choi, Seung-Hyuk; Gwon, Hyeon-Cheol

    2018-02-15

    There are limited data regarding the prognostic impact of angiographic complete revascularization (CR) in patients with chronic kidney disease (CKD). We sought to investigate the differential prognostic impact of angiographic CR over incomplete revascularization (IR), according to the presence of CKD in the drug-eluting stent era. Between 2003 and 2011 at Samsung Medical Center, consecutive patients with multivessel disease were stratified by the presence of CKD (estimated glomerular filtration rate <60 mL/min per 1.73 m 2 ) and classified according to angiographic CR (residual SYNTAX score=0) or IR. Clinical outcomes were compared between angiographic CR and IR, stratified by the presence of CKD. Primary outcome was patient-oriented composite outcomes (POCO, a composite of all-cause death, myocardial infarction, any revascularization) at 3 years. Inverse probability weighting was performed between the CR and IR groups. A total of 3224 patients were eligible for analysis: 2295 without CKD; 929 with CKD. Among non-CKD patients, angiographic CR showed a significantly lower risk of POCO than IR (17.2% versus 21.7%, adjusted hazard ratio 0.76, 95% confidence interval, 0.62-0.95, P =0.014), mainly driven by a significantly lower risk of any revascularization. Among CKD patients, however, angiographic CR was associated with a significantly higher risk of POCO than IR (37.7% versus 28.4%, adjusted hazard ratio 1.42, 95% confidence interval, 1.08%-1.85%, P =0.011), mainly driven by a significantly higher risk of nonfatal target vessel myocardial infarction. Angiographic CR was associated with reduced risk of POCO than IR in patients without CKD; however, it was associated with a significantly higher risk of POCO and nonfatal myocardial infarction in CKD patients. © 2018 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  8. [Exposition of the operator's eye lens and efficacy of radiation shielding in fluoroscopically guided interventions].

    Science.gov (United States)

    Galster, M; Guhl, C; Uder, M; Adamus, R

    2013-05-01

    Efficacy of radiation protection tools for the eye lens dose of the radiologist in fluoroscopic interventions. A patient phantom was exposed using a fluoroscopic system. Dose measurements were made at the eye location of the radiologist using an ionization chamber. The setting followed typical fluoroscopic interventions. The reduction of scattered radiation by the equipment-mounted shielding (undercouch drapes and overcouch top) was evaluated. The ceiling-suspended lead acrylic glass screen was tested in scattered radiation generated by a slab phantom. The protective properties of different lead glass goggles and lead acrylic visors were evaluated by thermoluminescence measurements on a head phantom in the primary beam. The exposition of the lens of about 110 to 550 μSv during radiologic interventions is only slightly reduced by the undercouch drapes. Applying the top in addition to the drapes reduces the lens dose by a factor of 2 for PA projections. In 25°LAO the dose is reduced by a factor between 1.2 and 5. The highest doses were measured for AP angulations furthermore the efficacy of the equipment-mounted shielding is minimal. The ceiling-suspended lead screen reduced scatter by a factor of about 30. The lead glass goggles and visors reduced the lens dose up to a factor of 8 to 10. Depending on the specific design, the tested models are less effective especially for radiation from lateral with cranial angulation of the beam. Occasionally the visors even caused an increase of dose. The exposition of the eye lens can be kept below the new occupational limit recommended by the ICRP if the radiation shielding equipment is used consistently. © Georg Thieme Verlag KG Stuttgart · New York.

  9. Fluoroscopically Guided Extraforaminal Cervical Nerve Root Blocks: Analysis of Epidural Flow of the Injectate with Respect to Needle Tip Position

    Science.gov (United States)

    Shipley, Kyle; Riew, K. Daniel; Gilula, Louis A.

    2013-01-01

    Study Design Retrospective evaluation of consecutively performed fluoroscopically guided cervical nerve root blocks. Objective To describe the incidence of injectate central epidural flow with respect to needle tip position during fluoroscopically guided extraforaminal cervical nerve root blocks (ECNRBs). Methods Between February 19, 2003 and June 11, 2003, 132 consecutive fluoroscopically guided ECNRBs performed with contrast media in the final injected material (injectate) were reviewed on 95 patients with average of 1.3 injections per patient. Fluoroscopic spot images documenting the procedure were obtained as part of standard quality assurance. An independent observer not directly involved in the procedures retrospectively reviewed the images, and the data were placed into a database. Image review was performed to determine optimal needle tip positioning for injectate epidural flow. Results Central epidural injectate flow was obtained in only 28.9% of injections with the needle tip lateral to midline of the lateral mass (zone 2). 83.8% of injectate went into epidural space when the needle tip was medial to midline of the lateral mass (zone 3). 100% of injectate flowed epidurally when the needle tip was medial to or at the medial cortex of the lateral mass (zone 4). There was no statistically significant difference with regards to central epidural flow and the needle tip position on lateral view. Conclusion To ensure central epidural flow with ECNRBs one must be prepared to pass the needle tip medial to midplane of the lateral mass or to medial cortex of the lateral mass. Approximately 16% of ECNRBs with needle tip medial to midline of the lateral mass did not flow into epidural space. One cannot claim a nerve block is an epidural block unless epidural flow of injectate is observed. PMID:24494176

  10. Evaluation of angiographic delayed vasospasm due to ruptured aneurysm in comparison with cerebral circulation time measured by IA-DSA

    Energy Technology Data Exchange (ETDEWEB)

    Okada, Yoshikazu; Shima, Takeshi; Nishida, Masahiro; Yamane, Kanji; Okita, Shinji; Hatayama, Takashi; Yoshida, Akira; Naoe, Yasutaka; Shiga, Naoko (Chugoku Rosai Hospital, Hiroshima (Japan))

    1994-05-01

    Delayed vasospasm due to ruptured aneurysm has been basically evaluated by angiographic changes in contrast to clinical features such as delayed ischemic neurological deficits (DIND). However, the discrepancies between angiographic and clinical findings have been pointed out. In this study, angiographic changes and cerebral circulation time in ruptured aneurysms were simultaneously investigated with IA-DSA. Thirty-two patients, who had ruptured aneurysms at the anterior circle of Willis and neck clippings at the acute stage, were investigated. Carotid angiogram was performed with IA-DSA on the 7-13th day after the attack. Angiographic changes were evaluated by Fischer's classification and circulation time was calculated in the following way. A time-density curve was obtained at the two ROI's: the C3-C4 portion and the rolandic vein. Circulation time was defined by the difference between the time showing peak optical density at the carotid and the venous portion. The control value of this circulation time obtained from 20 cases with non-rupture aneurysm and epilepsy was 3.4 sec (53 year old) on the average. X-ray CT scan examination was performed at the same time and clinical features were observed every day. Angiographically, 3 cases were free from vasospasm, 18 cases were found to present slight to moderate vasospasm, and 11 cases showed severe vasospasm. Circulation time in patients with no spasm was 3.6 seconds, in patients with slight to moderate vasospasm it was 4.3 seconds and in patients with severe vasospasm it was 6.8 seconds. Ten patients showing cerebral infarction on CT scans demonstrated significantly long circulation time, 7.0 seconds on the average. And all patients having severe vasospasm with circulation time more than 6 seconds presented DIND such as hemiparesis. (author).

  11. Fluoroscopic extraction of esophageal foreign body

    International Nuclear Information System (INIS)

    Chon, Su Bin; Han, Young Min; Chung, Gyung Ho; Sohn, Myung Hee; Kim, Chong Soo; Choi, Ki Chul; Song, Young Ho; Choi, Yeon Wha

    1993-01-01

    The purpose of this study is to report our 5 year experience with fluoroscopic removal of blunt esophageal foreign body or impacted food in 15 consecutive patients who were referred by endoscopists because they couln't remove it endoscopically. The foreign body or impacted food was a piece of meat, a bean, a badug stone or a beef bone. Thirteen patients had underlying disease (11 of corrosive stricture, 2 of postopertive stricture) but 2 patient did not. We removed the object using one of the following 4 techniques: Basket extraction technique. Foley catheter technique, single balloon technique (dilatation of stenosis for passing the food into the stomach and for the treatment of the stricture as well), double balloon technique (removal of the foregin body by trapping it with two valvuloplasty balloons). Removal was successful in all patients. Esophageal performation occurred in one patient using the sibgle balloon technique, who treated nonoperatively by means of fasting, antibiotics and parenteral alimentation. No procedure related death occurred in these series. In conclusion, fliuroscopic removal of blunt esophageal foreign bodies of impacted food with various techniques is promising alternative to esophagoscopic removal

  12. An angiographic technique for coronary fractional flow reserve measurement: in vivo validation.

    Science.gov (United States)

    Takarada, Shigeho; Zhang, Zhang; Molloi, Sabee

    2013-03-01

    Fractional flow reserve (FFR) is an important prognostic determinant in a clinical setting. However, its measurement currently requires the use of invasive pressure wire, while an angiographic technique based on first-pass distribution analysis and scaling laws can be used to measure FFR using only image data. Eight anesthetized swine were instrumented with flow probe on the proximal segment of the left anterior descending (LAD) coronary arteries. Volumetric blood flow from the flow probe (Qp), coronary pressure (Pa) and right atrium pressure (Pv) were continuously recorded. Flow probe-based FFR (FFRq) was measured from the ratio of flow with and without stenosis. To determine the angiography-based FFR (FFRa), the ratio of blood flow in the presence of a stenosis (QS) to theoretically normal blood flow (QN) was calculated. A region of interest in the LAD arterial bed was drawn to generate time-density curves using angiographic images. QS was measured using a time-density curve and the assumption that blood was momentarily replaced with contrast agent during the injection. QN was estimated from the total coronary arterial volume using scaling laws. Pressure-wire measurements of FFR (FFRp), which was calculated from the ratio of distal coronary pressure (Pd) divided by proximal pressure (Pa), were continuously obtained during the study. A total of 54 measurements of FFRa, FFRp, and FFRq were taken. FFRa showed a good correlation with FFRq (FFRa = 0.97 FFRq +0.06, r(2) = 0.80, p < 0.001), although FFRp overestimated the FFRq (FFRp = 0.657 FFRq + 0.313, r(2) = 0.710, p < 0.0001). Additionally, the Bland-Altman analysis showed a close agreement between FFRa and FFRq. This angiographic technique to measure FFR can potentially be used to evaluate both anatomical and physiological assessments of a coronary stenosis during routine diagnostic cardiac catheterization that requires no pressure wires.

  13. SU-G-JeP1-11: Feasibility Study of Markerless Tracking Using Dual Energy Fluoroscopic Images for Real-Time Tumor-Tracking Radiotherapy System

    Energy Technology Data Exchange (ETDEWEB)

    Shiinoki, T; Shibuya, K [Yamaguchi University, Ube, Yamaguchi (Japan); Sawada, A [Kyoto college of medical science, Nantan, Kyoto (Japan); Uehara, T; Yuasa, Y; Koike, M; Kawamura, S [Yamaguchi University Hospital, Ube, Yamaguchi (Japan)

    2016-06-15

    Purpose: The new real-time tumor-tracking radiotherapy (RTRT) system was installed in our institution. This system consists of two x-ray tubes and color image intensifiers (I.I.s). The fiducial marker which was implanted near the tumor was tracked using color fluoroscopic images. However, the implantation of the fiducial marker is very invasive. Color fluoroscopic images enable to increase the recognition of the tumor. However, these images were not suitable to track the tumor without fiducial marker. The purpose of this study was to investigate the feasibility of markerless tracking using dual energy colored fluoroscopic images for real-time tumor-tracking radiotherapy system. Methods: The colored fluoroscopic images of static and moving phantom that had the simulated tumor (30 mm diameter sphere) were experimentally acquired using the RTRT system. The programmable respiratory motion phantom was driven using the sinusoidal pattern in cranio-caudal direction (Amplitude: 20 mm, Time: 4 s). The x-ray condition was set to 55 kV, 50 mA and 105 kV, 50 mA for low energy and high energy, respectively. Dual energy images were calculated based on the weighted logarithmic subtraction of high and low energy images of RGB images. The usefulness of dual energy imaging for real-time tracking with an automated template image matching algorithm was investigated. Results: Our proposed dual energy subtraction improve the contrast between tumor and background to suppress the bone structure. For static phantom, our results showed that high tracking accuracy using dual energy subtraction images. For moving phantom, our results showed that good tracking accuracy using dual energy subtraction images. However, tracking accuracy was dependent on tumor position, tumor size and x-ray conditions. Conclusion: We indicated that feasibility of markerless tracking using dual energy fluoroscopic images for real-time tumor-tracking radiotherapy system. Furthermore, it is needed to investigate the

  14. Reduction of radiation exposure while maintaining high-quality fluoroscopic images during interventional cardiology using novel x-ray tube technology with extra beam filtering.

    Science.gov (United States)

    den Boer, A; de Feyter, P J; Hummel, W A; Keane, D; Roelandt, J R

    1994-06-01

    Radiographic technology plays an integral role in interventional cardiology. The number of interventions continues to increase, and the associated radiation exposure to patients and personnel is of major concern. This study was undertaken to determine whether a newly developed x-ray tube deploying grid-switched pulsed fluoroscopy and extra beam filtering can achieve a reduction in radiation exposure while maintaining fluoroscopic images of high quality. Three fluoroscopic techniques were compared: continuous fluoroscopy, pulsed fluoroscopy, and a newly developed high-output pulsed fluoroscopy with extra filtering. To ascertain differences in the quality of images and to determine differences in patient entrance and investigator radiation exposure, the radiated volume curve was measured to determine the required high voltage levels (kVpeak) for different object sizes for each fluoroscopic mode. The fluoroscopic data of 124 patient procedures were combined. The data were analyzed for radiographic projections, image intensifier field size, and x-ray tube kilovoltage levels (kVpeak). On the basis of this analysis, a reference procedure was constructed. The reference procedure was tested on a phantom or dummy patient by all three fluoroscopic modes. The phantom was so designed that the kilovoltage requirements for each projection were comparable to those needed for the average patient. Radiation exposure of the operator and patient was measured during each mode. The patient entrance dose was measured in air, and the operator dose was measured by 18 dosimeters on a dummy operator. Pulsed compared with continuous fluoroscopy could be performed with improved image quality at lower kilovoltages. The patient entrance dose was reduced by 21% and the operator dose by 54%. High-output pulsed fluoroscopy with extra beam filtering compared with continuous fluoroscopy improved the image quality, lowered the kilovoltage requirements, and reduced the patient entrance dose by 55% and

  15. Internal carotid arterial occlusion in computed tomography. Correlation of CT and angiographic findings

    Energy Technology Data Exchange (ETDEWEB)

    Harada, K.; Miura, T.; Nishikubo, Y.; Kawai, R.; Mitomo, M. (Osaka Univ. (Japan). Faculty of Medicine)

    1981-09-01

    The computed tomographic appearance of internal carotid arterial occlusion was reviewed in 33 patients. In 23 of them, who underwent 4-vessel study, the angiographic and CT findings were compared. Ten patients were disclosed to have watershed infarction by CT. Seven of them had watershed processes in the centrum semiovale which were considered to be terminal infarction. Patients who showed watershed infarction under CT revealed inadequate circle of Willis and well-developed cortical anastomosis under angiography. Unilaterally accentuated cerebral atrophy, which we have called asymmetrical atrophy in this paper, was noted in 10 patients. The findings of asymmetrical cerebral atrophy sometimes resemble the changes secondary to old infarction. However, the changes in the lateral ventricle caused by asymmetrical cerebral atrophy are somewhat different from those resulting from old infarction. The angiographic findings suggested that asymmetrical cerebral atrophy is, in addition to being associated with incomplete circle of Willis, also associated with local circulatory disturbances which further decrease the regional cerebral blood flow in the affected hemisphere.

  16. Angiographic differentiation of type of ventricular septal defects

    International Nuclear Information System (INIS)

    Cheon, Mal Soon; Park, Hee Young; Kim, Yang Sook

    1989-01-01

    Defects of the ventricular septum are the commonest type of congenital cardiac malformations. A classification with axial angiography of the subtypes of ventricular septal defects is proposed on the study of 126 patients with defects of the ventricular septum. The results were as follows: 1. The incidence of the ventricular septal defects was 39.6% of congenital heart malformation. 2. The sex distribution of cases were 70 males and 56 females, the age ranged from 13 months to 26 years. 3. Angiographic features seen by axial angiography were as follows: a. Perimembranous defects as seen on long axial view of left ventriculogram were in continuity wity aortic valve. The relation of the defect to the tricuspid valve allows distinction of the extension of the preimembranous defect toward inlet, trabecular, or infundibular zones. This relation was determined angiographically, using the course of the contrast medium from the left ventricle through the ventricular septal defect, opacifying the right ventricle. In inlet excavation, the shunted blood opacified the recess between septal leaflet of tricuspid valve and interventricular septum in early phase, in infundibular excavation, opacified the recess between anterior leaflet of tricuspid valve and anterior free wall of right ventricle and in trabecular excavation, the shunted blood traversed anterior portion of tricuspid valve ring, opacified trabecular portion of right ventricle. b. Muscular defects were separated from the semilunar and atrioventricular valves. c, Subarterial defects were related to both semilunar valves, and they were best demonstrated on the elongated right anterior oblique view of the left ventriculogram. d. Total infundibular defects were profiled in right anterior oblique 30 and long axial view, subaortic in location in both views

  17. Selecting appropriate gastroenteric contrast media for diagnostic fluoroscopic imaging in infants and children: a practical approach.

    Science.gov (United States)

    Callahan, Michael J; Talmadge, Jennifer M; MacDougall, Robert D; Kleinman, Patricia L; Taylor, George A; Buonomo, Carlo

    2017-04-01

    In our experience, questions about the appropriate use of enteric contrast media for pediatric fluoroscopic studies are common. The purpose of this article is to provide a comprehensive review of enteric contrast media used for pediatric fluoroscopy, highlighting the routine use of these media at a large tertiary care pediatric teaching hospital.

  18. Insertion of central venous catheters for hemodialysis using angiographic techniques in patients with previous multiple catheterizations

    Energy Technology Data Exchange (ETDEWEB)

    Kotsikoris, Ioannis, E-mail: gkotsikoris@gmail.com [Department of Vascular Surgery, “Erythros Stauros” General Hospital (Greece); Zygomalas, Apollon, E-mail: azygomalas@upatras.gr [Department of General Surgery, University Hospital of Patras (Greece); Papas, Theofanis, E-mail: pfanis@otenet.gr [Department of Vascular Surgery, “Erythros Stauros” General Hospital (Greece); Maras, Dimitris, E-mail: dimmaras@gmail.com [Department of Vascular Surgery, “Erythros Stauros” General Hospital (Greece); Pavlidis, Polyvios, E-mail: polpavlidis@yahoo.gr [Department of Vascular Surgery, “Erythros Stauros” General Hospital (Greece); Andrikopoulou, Maria, E-mail: madric@gmail.com [Department of Vascular Surgery, “Erythros Stauros” General Hospital (Greece); Tsanis, Antonis, E-mail: atsanis@gmail.com [Department of Interventional Radiology, “Erythros Stauros” General Hospital (Greece); Alivizatos, Vasileios, E-mail: valiviz@hol.gr [Department of General Surgery and Artificial Nutrition Unit, “Agios Andreas” General Hospital of Patras (Greece); Bessias, Nikolaos, E-mail: bessias@otenet.gr [Department of Vascular Surgery, “Erythros Stauros” General Hospital (Greece)

    2012-09-15

    Introduction: Central venous catheter placement is an effective alternative vascular access for dialysis in patients with chronic renal failure. The purpose of this study was to evaluate the insertion of central venous catheters for hemodialysis using angiographic techniques in patients with previous multiple catheterizations in terms of efficacy of the procedure and early complications. Materials and methods: Between 2008 and 2010, the vascular access team of our hospital placed 409 central venous catheters in patients with chronic renal failure. The procedure was performed using the Seldinger blind technique. In 18 (4.4%) cases it was impossible to advance the guidewire, and so the patients were transported to the angiography suite. Results: Using the angiographic technique, the guidewire was advanced in order to position the central venous catheter. The latter was inserted into the subclavian vein in 12 (66.6%) cases, into the internal jugular vein in 4 (22.2%) and into the femoral vein in 2 (11.1%) cases. There was only one complicated case with severe arrhythmia in 1 (5.5%) patient. Conclusion: Our results suggest that insertion of central venous catheters using angiographic techniques in hemodialysis patients with previous multiple catheterizations is a safe and effective procedure with few complications and high success rates.

  19. Insertion of central venous catheters for hemodialysis using angiographic techniques in patients with previous multiple catheterizations

    International Nuclear Information System (INIS)

    Kotsikoris, Ioannis; Zygomalas, Apollon; Papas, Theofanis; Maras, Dimitris; Pavlidis, Polyvios; Andrikopoulou, Maria; Tsanis, Antonis; Alivizatos, Vasileios; Bessias, Nikolaos

    2012-01-01

    Introduction: Central venous catheter placement is an effective alternative vascular access for dialysis in patients with chronic renal failure. The purpose of this study was to evaluate the insertion of central venous catheters for hemodialysis using angiographic techniques in patients with previous multiple catheterizations in terms of efficacy of the procedure and early complications. Materials and methods: Between 2008 and 2010, the vascular access team of our hospital placed 409 central venous catheters in patients with chronic renal failure. The procedure was performed using the Seldinger blind technique. In 18 (4.4%) cases it was impossible to advance the guidewire, and so the patients were transported to the angiography suite. Results: Using the angiographic technique, the guidewire was advanced in order to position the central venous catheter. The latter was inserted into the subclavian vein in 12 (66.6%) cases, into the internal jugular vein in 4 (22.2%) and into the femoral vein in 2 (11.1%) cases. There was only one complicated case with severe arrhythmia in 1 (5.5%) patient. Conclusion: Our results suggest that insertion of central venous catheters using angiographic techniques in hemodialysis patients with previous multiple catheterizations is a safe and effective procedure with few complications and high success rates

  20. Comparison of equilibrium radionuclide and contrast angiographic measurements of left ventricular peak ejection and filling rates and their time intervals

    Energy Technology Data Exchange (ETDEWEB)

    Sugrue, D.D.; Dickie, S.; Newman, H.; Myers, M.J.; Lavender, J.P.; McKenna, W.J. (Royal Postgraduate Medical School, London (UK))

    1984-10-01

    A comparison has been made of the equilibrium radionuclide and contrast angiographic estimates of normalized peak rates of ejection (PER) and filling (PFR) and their time intervals in twenty-one patients with cardiac disorders. Contrast angiographic and radionuclide measurements of left ventricular ejection fraction (LVEF), PER and PFR correlated well but time intervals correlated poorly. Mean values for radionuclide LVEF, PER and PFR were significantly lower and radionuclide time intervals were significantly longer compared to contrast angiography measurements.

  1. SU-D-209-01: Can Fluoroscopic Air-Kerma Rates Be Reliably Measured with Solid-State Meters?

    International Nuclear Information System (INIS)

    Feng, C; Thai, L; Wagner, L; Ozus, B

    2016-01-01

    Purpose: Ionization chambers remain the standard for calibration of air-kerma rate measuring devices. Despite their strong energy-dependent response, solid state radiation detectors are increasingly used, primarily due to their efficiency in making standardized measurements. To test the reliability of these devices in measuring air-kerma rates, we compared ion chambers measurements with solid-state measurements for various mobile fluoroscopes operated at different beam qualities and air-kerma rates. Methods: Six mobile fluoroscopes (GE OEC models 9800 and 9900) were used to generate test beams. Using various field sizes and dose rate controls, copper attenuators and a lead attenuator were placed at the image receptor in varying combinations to generate a range of air-kerma rates. Air-kerma rates at 30 centimeters from the image receptors were measured using two 6-cm"3 ion chambers with electrometers (Radcal, models 1015 and 9015) and two with solid state detectors (Unfors Xi and Raysafe X2). No error messages occurred during measurements. However, about two months later, one solid-state device stopped working and was replaced by the manufacturer. Two out of six mobile fluoroscopic units were retested with the replacement unit. Results: Generally, solid state and ionization chambers agreed favorably well, with two exceptions. Before replacement of the detector, the Xi meter when set in the “RF High” mode deviated from ion chamber readings by factors of 2 and 10 with no message indicating error in measurement. When set in the “RF Low” mode, readings were within −4% to +3%. The replacement Xi detector displayed messages alerting the user when settings were not compatible with air-kerma rates. Conclusion: Air-kerma rates can be measured favorably well using solid-state devices, but users must be aware of the possibility that readings can be grossly in error with no discernible indication for the deviation.

  2. SU-D-209-01: Can Fluoroscopic Air-Kerma Rates Be Reliably Measured with Solid-State Meters?

    Energy Technology Data Exchange (ETDEWEB)

    Feng, C; Thai, L; Wagner, L [The University of Texas Health Science Center at Houston, Houston, TX (United States); Ozus, B [CHI St Luke’s Health, Baylor St Luke’s Medical Center, Houston, TX (United States)

    2016-06-15

    Purpose: Ionization chambers remain the standard for calibration of air-kerma rate measuring devices. Despite their strong energy-dependent response, solid state radiation detectors are increasingly used, primarily due to their efficiency in making standardized measurements. To test the reliability of these devices in measuring air-kerma rates, we compared ion chambers measurements with solid-state measurements for various mobile fluoroscopes operated at different beam qualities and air-kerma rates. Methods: Six mobile fluoroscopes (GE OEC models 9800 and 9900) were used to generate test beams. Using various field sizes and dose rate controls, copper attenuators and a lead attenuator were placed at the image receptor in varying combinations to generate a range of air-kerma rates. Air-kerma rates at 30 centimeters from the image receptors were measured using two 6-cm{sup 3} ion chambers with electrometers (Radcal, models 1015 and 9015) and two with solid state detectors (Unfors Xi and Raysafe X2). No error messages occurred during measurements. However, about two months later, one solid-state device stopped working and was replaced by the manufacturer. Two out of six mobile fluoroscopic units were retested with the replacement unit. Results: Generally, solid state and ionization chambers agreed favorably well, with two exceptions. Before replacement of the detector, the Xi meter when set in the “RF High” mode deviated from ion chamber readings by factors of 2 and 10 with no message indicating error in measurement. When set in the “RF Low” mode, readings were within −4% to +3%. The replacement Xi detector displayed messages alerting the user when settings were not compatible with air-kerma rates. Conclusion: Air-kerma rates can be measured favorably well using solid-state devices, but users must be aware of the possibility that readings can be grossly in error with no discernible indication for the deviation.

  3. Percutaneous Transhepatic Drainage of Inaccessible Abdominal Abscesses Following Abdominal Surgery Under Real-Time CT-Fluoroscopic Guidance

    International Nuclear Information System (INIS)

    Yamakado, Koichiro; Takaki, Haruyuki; Nakatsuka, Atsuhiro; Kashima, Masataka; Uraki, Junji; Yamanaka, Takashi; Takeda, Kan

    2010-01-01

    This study evaluated the safety, feasibility, and clinical utility of transhepatic drainage of inaccessible abdominal abscesses retrospectively under real-time computed tomographic (CT) guidance. For abdominal abscesses, 12 consecutive patients received percutaneous transhepatic drainage. Abscesses were considered inaccessible using the usual access route because they were surrounded by the liver and other organs. The maximum diameters of abscesses were 4.6-9.5 cm (mean, 6.7 ± 1.4 cm). An 8-Fr catheter was advanced into the abscess cavity through the liver parenchyma using real-time CT fluoroscopic guidance. Safety, feasibility, procedure time, and clinical utility were evaluated. Drainage catheters were placed with no complications in abscess cavities through the liver parenchyma in all patients. The mean procedure time was 18.8 ± 9.2 min (range, 12-41 min). All abscesses were drained. They shrank immediately after catheter placement. In conclusions, this transhepatic approach under real-time CT fluoroscopic guidance is a safe, feasible, and useful technique for use of drainage of inaccessible abdominal abscesses.

  4. Determination of ETSPLs for the Sennheiser HDA 200 headphone and the Etymotic Research ER-2 insertphone and MAF in the frequency range 125 Hz to 16 kHz

    DEFF Research Database (Denmark)

    Han, Loc A.; Poulsen, Torben

    1997-01-01

    The binaural free field hearing threshold for pure tones (the minimum audible field, MAF) and Equivalent Threshold Sound Pressure Levels (ETSPL) for the Sennheiser HDA 200 earphone and the Etymotic Research ER-2 insert earphone have been determined for thirty-one otologically normal test subjects...

  5. The need for using fluoroscopic guidance to obtain gastric biopsies when in search of Helicobacter pylori with a nonendoscopic method

    International Nuclear Information System (INIS)

    Bender, Greg N.; Mullins, Daniel J.; Makuch, Richard S.

    1999-01-01

    Purpose: Nonendoscopic, fluoroscopic biopsy of the gastric mucosa, following barium examination of the stomach, has gained attention with its ease of performance and cost savings potential over endoscopy. Endoscopic research concerning the efficacy of biopsy sites has revealed an increased sensitivity of antral biopsies over greater curvature biopsies for the detection of Helicobacter pylori. Fluoroscopically guided biopsies of the gastric mucosal are studied to determine whether such a difference between site sensitivity held true. If not, blind biopsy through a nasogastric tube, which traditionally samples only the greater curvature, might prove an even less expensive alternative. Materials and methods: Seventy-two patients underwent nonendoscopic, fluoroscopically guided, mucosal biopsy of both the gastric antrum and the greater curvature of the stomach. Pathologic reports from both sites, using each patient as their own control, are compared to assess site sensitivity in the diagnosis of H. pylori gastritis. Results: The sensitivity for the detection of H. pylori gastritis by antral biopsy is 89% whereas the sensitivity of greater curvature biopsy is 62%. The difference is considered clinically significant at P≤0.05. Conclusions: This study confirms the need for antral biopsies when desiring a nonendoscopic approach to gastric mucosal sampling, in order to obtain a reasonable yield of data in dyspeptic patients with H. pylori gastritis. Blind techniques cannot reliably reach the antrum. Fluoroscopy can, and remains a less expensive alternative to endoscopy

  6. The need for using fluoroscopic guidance to obtain gastric biopsies when in search of Helicobacter pylori with a nonendoscopic method

    Energy Technology Data Exchange (ETDEWEB)

    Bender, Greg N.; Mullins, Daniel J.; Makuch, Richard S

    1999-12-01

    Purpose: Nonendoscopic, fluoroscopic biopsy of the gastric mucosa, following barium examination of the stomach, has gained attention with its ease of performance and cost savings potential over endoscopy. Endoscopic research concerning the efficacy of biopsy sites has revealed an increased sensitivity of antral biopsies over greater curvature biopsies for the detection of Helicobacter pylori. Fluoroscopically guided biopsies of the gastric mucosal are studied to determine whether such a difference between site sensitivity held true. If not, blind biopsy through a nasogastric tube, which traditionally samples only the greater curvature, might prove an even less expensive alternative. Materials and methods: Seventy-two patients underwent nonendoscopic, fluoroscopically guided, mucosal biopsy of both the gastric antrum and the greater curvature of the stomach. Pathologic reports from both sites, using each patient as their own control, are compared to assess site sensitivity in the diagnosis of H. pylori gastritis. Results: The sensitivity for the detection of H. pylori gastritis by antral biopsy is 89% whereas the sensitivity of greater curvature biopsy is 62%. The difference is considered clinically significant at P{<=}0.05. Conclusions: This study confirms the need for antral biopsies when desiring a nonendoscopic approach to gastric mucosal sampling, in order to obtain a reasonable yield of data in dyspeptic patients with H. pylori gastritis. Blind techniques cannot reliably reach the antrum. Fluoroscopy can, and remains a less expensive alternative to endoscopy.

  7. Angiographically Negative Acute Arterial Upper and Lower Gastrointestinal Bleeding: Incidence, Predictive Factors, and Clinical Outcomes

    International Nuclear Information System (INIS)

    Kim, Jin Hyoung; Shin, Ji Hoon; Yoon, Hyun Ki; Chae, Eun Young; Myung, Seung Jae; Ko, Gi Young; Gwon, Dong Il; Sung, Kyu Bo

    2009-01-01

    To evaluate the incidence, predictive factors, and clinical outcomes of angiographically negative acute arterial upper and lower gastrointestinal (GI) bleeding. From 2001 to 2008, 143 consecutive patients who underwent an angiography for acute arterial upper or lower GI bleeding were examined. The angiographies revealed a negative bleeding focus in 75 of 143 (52%) patients. The incidence of an angiographically negative outcome was significantly higher in patients with a stable hemodynamic status (p < 0.001), or in patients with lower GI bleeding (p = 0.032). A follow-up of the 75 patients (range: 0-72 months, mean: 8 ± 14 months) revealed that 60 of the 75 (80%) patients with a negative bleeding focus underwent conservative management only, and acute bleeding was controlled without rebleeding. Three of the 75 (4%) patients underwent exploratory surgery due to prolonged bleeding; however, no bleeding focus was detected. Rebleeding occurred in 12 of 75 (16%) patients. Of these, six patients experienced massive rebleeding and died of disseminated intravascular coagulation within four to nine hours after the rebleeding episode. Four of the 16 patients underwent a repeat angiography and the two remaining patients underwent a surgical intervention to control the bleeding. Angiographically negative results are relatively common in patients with acute GI bleeding, especially in patients with a stable hemodynamic status or lower GI bleeding. Most patients with a negative bleeding focus have experienced spontaneous resolution of their condition

  8. Angiographically Negative Acute Arterial Upper and Lower Gastrointestinal Bleeding: Incidence, Predictive Factors, and Clinical Outcomes

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jin Hyoung; Shin, Ji Hoon; Yoon, Hyun Ki; Chae, Eun Young; Myung, Seung Jae; Ko, Gi Young; Gwon, Dong Il; Sung, Kyu Bo [Asan Medical Center, Seoul (Korea, Republic of)

    2009-08-15

    To evaluate the incidence, predictive factors, and clinical outcomes of angiographically negative acute arterial upper and lower gastrointestinal (GI) bleeding. From 2001 to 2008, 143 consecutive patients who underwent an angiography for acute arterial upper or lower GI bleeding were examined. The angiographies revealed a negative bleeding focus in 75 of 143 (52%) patients. The incidence of an angiographically negative outcome was significantly higher in patients with a stable hemodynamic status (p < 0.001), or in patients with lower GI bleeding (p = 0.032). A follow-up of the 75 patients (range: 0-72 months, mean: 8 {+-} 14 months) revealed that 60 of the 75 (80%) patients with a negative bleeding focus underwent conservative management only, and acute bleeding was controlled without rebleeding. Three of the 75 (4%) patients underwent exploratory surgery due to prolonged bleeding; however, no bleeding focus was detected. Rebleeding occurred in 12 of 75 (16%) patients. Of these, six patients experienced massive rebleeding and died of disseminated intravascular coagulation within four to nine hours after the rebleeding episode. Four of the 16 patients underwent a repeat angiography and the two remaining patients underwent a surgical intervention to control the bleeding. Angiographically negative results are relatively common in patients with acute GI bleeding, especially in patients with a stable hemodynamic status or lower GI bleeding. Most patients with a negative bleeding focus have experienced spontaneous resolution of their condition.

  9. Lower radiation burden in state of the art fluoroscopic cystography compared to direct isotope cystography in children.

    Science.gov (United States)

    Haid, Bernhard; Becker, Tanja; Koen, Mark; Berger, Christoph; Langsteger, Werner; Gruy, Bernhard; Putz, Ernst; Haid, Stephanie; Oswald, Josef

    2015-02-01

    Both, fluoroscopic voiding cystourethrography (fVCUG) and direct isotope cystography (DIC) are diagnostic tools commonly used in pediatric urology. Both methods can detect vesicoureteral reflux (VUR) with a high sensitivity. Whilst the possibility to depict anatomical details and important structures as for instance the urethra in boys or the detailed calyceal anatomy are advantages of fVCUG, a lower radiation burden is thought to be the main advantage of DIC. In the last decade, however, a rapid technical evolution has occurred in fluoroscopy by implementing digital grid-controlled, variable rate, pulsed acquisition technique. As documented in literature this led to a substantial decrease in radiation burden conferred during fVCUGs. To question the common belief that direct isotope cystography confers less radiation burden compared to state of the art fluoroscopic voiding cystography. Radiation burden of direct isotope cystography in 92 children and in additional 7 children after an adaption of protocol was compared to radiation burden of fluoroscopic voiding cystourethrography in 51. The examinations were performed according to institutional protocols. For calculation of mean effective radiation dose [mSv] for either method published physical models correcting for age and sex were used. For DIC the model published by Stabin et al., 1998 was applied, for fVCUG two different physical models were used (Schultz et al., 1999, Lee et al., 2009). The radiation burden conferred by direct isotope cystography was significantly higher as for fluoroscopic voiding cystourethrography. The mean effective radiation dose for direct isotope cystography accounted to 0.23 mSv (± 0.34 m, median 0.085 mSv) compared to 0.015 mSv (± 0.013, median 0.008 mSv, model by Schultz et al.) - 0.024 mSv (± 0.018, median 0.018 mSv, model by Lee et al.) for fluoroscopic voiding cystourethrography. After a protocol adaption to correct for a longer examination time in DIC that was caused by

  10. Effective dose and dose to crystalline lens during angiographic procedures

    International Nuclear Information System (INIS)

    Pages, J.

    1998-01-01

    The highest radiation doses levels received by radiologists are observed during interventional procedures. Doses to forehead and neck received by a radiologist executing angiographic examinations at the department of radiology at the academic hospital (AZ-VUB) have been measured for a group of 34 examinations. The doses to crystalline lens and the effective doses for a period of one year have been estimated. For the crystalline lens the maximum dose approaches the ICRP limit, that indicates the necessity for the radiologist to use leaded glasses. (N.C.)

  11. MR imaging assessment of cerebral vascular disease: A combination of angiographic and parenchymal techniques

    International Nuclear Information System (INIS)

    Masaryk, T.J.; Modic, M.T.; Ross, J.S.; Ruggieri, P.; Laub, G.; Haacke, E.M.

    1988-01-01

    This study tested the accuracy and clinical utility of a three-dimensional MR angiographic technique of the cervical carotids in combination with a routine spin-echo examination of the brain as a screening examination for cerebrovascular disease in 23 patients. The technique used a fast low-angle shot sequence with a reduced echo time and voxel size, gradient refocusing, and time of flight effects to minimize signal loss secondary to phase dispersion and maximize vessel contrast. Subsequent multiplanar three-dimensional reconstructions were obtained at 5 0 increments about the z-axis via ray-tracing linear thresholding algorithms. Examinations were compared with IV/IA-digital subtraction angiography or Doppler US as the objective of accuracy. Results of this ongoing study indicate that an MR angiographic screening examination can be coupled with routine brain MR imaging with only a 10-14 minute extension of examination time, providing both a vascular and a parenchymal evaluation

  12. Clinical and angiographic characteristics of patients likely to have vulnerable plaques: analysis from the PROSPECT study.

    Science.gov (United States)

    Bourantas, Christos V; Garcia-Garcia, Hector M; Farooq, Vasim; Maehara, Akiko; Xu, Ke; Généreux, Philippe; Diletti, Roberto; Muramatsu, Takashi; Fahy, Martin; Weisz, Giora; Stone, Gregg W; Serruys, Patrick W

    2013-12-01

    This study sought to determine the clinical and angiographic variables that would identify patients with high-risk "vulnerable" coronary plaques. In the PROSPECT (Providing Regional Observations to Study Predictors of Events in the Coronary Tree) study, in patients successfully treated for acute coronary syndrome (ACS), plaque composition, plaque burden, and minimal luminal area as detected by 3-vessel radiofrequency intravascular ultrasound (IVUS) imaging were associated with an increased risk of developing future events from untreated atherosclerotic lesions (vulnerable plaques). Whether baseline demographic and angiographic findings can be used to identify patients most likely to have vulnerable coronary plaques has not been examined. On the basis of 3-vessel radiofrequency IVUS imaging, patents in the PROSPECT trial were classified in 2 groups according to whether or not one or more untreated high-risk plaques were present, defined as having ≥2 high-risk features (a thin-cap fibroatheroma, plaque burden ≥70%, and/or minimal luminal area ≤4 mm(2)). The high-risk group (those with one or more high-risk lesions) had higher Framingham risk score (7.5 ± 3.4 vs. 6.9 ± 3.3; p = 0.04), more extensive coronary artery disease, and more nonculprit lesion-related cardiovascular events during the 3-year follow-up (hazard ratio: 2.63; 95% confidence interval: 1.62 to 3.66; p < 0.0001). However, demographic factors had poor discrimination in detecting high-risk patients (area under the curve 0.55), and discrimination was only slightly improved when angiographic variables were entered into the model (area under the curve 0.64). Clinical and angiographic characteristics had poor predictive accuracy in identifying patients with untreated high-risk plaques related to future adverse events. This finding highlights the potential value of comprehensive 3-vessel imaging assessment (either invasive or noninvasive) to evaluate plaque phenotype for more accurate risk

  13. Angiographic findings of collateral vessels in cervicofacial vascular lesions with previously ligated carotid artery

    International Nuclear Information System (INIS)

    Na, Dong Gyu; Han, Moon Hee; Chang, Kee Hyun; Han, Gi Seok; Yeon, Kung Mo

    1995-01-01

    The purpose of this study is to describe the angiographic findings of collateral vessels in cervicofacial vascular lesions with previously ligated carotid arteries and to evaluate the extent of angiographic assessment needed before embolization. We retrospectively reviewed 10 cervicofacial vascular lesions with previously ligated carotid artery, which were 6 cases of arteriovenous malformation, 2 cases of carotid cavernous fistula, 1 case of hemangioma and 1 case of arteriovenous malformation with carotid cavernous fistula. The previously ligated arteries are proximal external carotid artery (n = 5), branches of external carotid artery (n = 2) and common carotid artery (n = 3). Common carotid artery or internal carotid artery (n = 9), vertebral artery (n = 5), ipsilateral external carotid artery (n = 4), contralateral external carotid artery (n = 5), costocervical trunk (n = 2), thyrocervical trunk (n = 2) were assessed by conventional angiography. Angiography of both carotid and vertebral arteries was performed in 5 cases. The collateral vascular channels were inferolateral trunk of internal carotid artery (n = 8), vertebral artery (n = 5), contralateral external carotid artery (n = 5), ipsilateral external carotid artery (n = 4), deep cervical artery (n = 2) and ascending cervical artery (n = 1). Embolization were performed in 9 cases with operative cannulation (n = 4), embolization via collateral branches of ipsilateral external carotid artery (n = 1), embolization via collateral branches of contralateral external carotid artery (n = 3) and balloon occlusion via direct puncture (n = 1). The collateral channels in cervicofacial vascular lesions with previously ligated carotid artery were inferolateral trunk of internal carotid artery, contralateral or ipsilateral external carotid artery, vertebral artery, deep cervical artery and ascending cervical artery on angiography. Complete angiographic assessment of possible collateral channels is mandatory for the

  14. Under digital fluoroscopic guidance multiple-point injection with absolute alcohol and pinyangmycin for the treatment of superficial venous malformations

    International Nuclear Information System (INIS)

    Yang Ming; Xiao Gang; Peng Youlin

    2010-01-01

    Objective: to investigate the therapeutic efficacy of multiple-point injection with absolute alcohol and pinyangmycin under digital fluoroscopic guidance for superficial venous malformations. Methods: By using a disposal venous transfusion needle the superficial venous malformation was punctured and then contrast media lohexol was injected in to visualize the tumor body, which was followed by the injection of ethanol and pinyangmycin when the needle was confirmed in the correct position. The procedure was successfully performed in 31 patients. The clinical results were observed and analyzed. Results: After one treatment complete cure was achieved in 21 cases and marked effect was obtained in 8 cases, with a total effectiveness of 93.5%. Conclusion: Multiple-point injection with ethanol and pinyangmycin under digital fluoroscopic guidance is an effective and safe technique for the treatment of superficial venous malformations, especially for the lesions that are deeply located and ill-defined. (authors)

  15. Patient radiation dose in diagnostic and interventional procedures for intracranial aneurysms: Experience at a single center

    International Nuclear Information System (INIS)

    Chun, Chang Woo; Kim, Bum Soo; Lee, Cheol Hyoun; Ihn, Yon Kwon; Shin, Yong Sam

    2014-01-01

    To assess patient radiation doses during cerebral angiography and embolization of intracranial aneurysms in a large sample size from a single center. We studied a sample of 439 diagnostic and 149 therapeutic procedures for intracranial aneurysms in 480 patients (331 females, 149 males; median age, 57 years; range, 21-88 years), which were performed in 2012 with a biplane unit. Parameters including fluoroscopic time, dose-area product (DAP), and total angiographic image frames were obtained and analyzed. Mean fluoroscopic time, total mean DAP, and total image frames were 12.6 minutes, 136.6 +/- 44.8 Gy-cm 2 , and 251 +/- 49 frames for diagnostic procedures, 52.9 minutes, 226.0 +/- 129.2 Gy-cm 2 , and 241 frames for therapeutic procedures, and 52.2 minutes, 334.5 +/- 184.6 Gy-cm 2 , and 408 frames for when both procedures were performed during the same session. The third quartiles for diagnostic reference levels (DRLs) were 14.0, 61.1, and 66.1 minutes for fluoroscopy time, 154.2, 272.8, and 393.8 Gy-cm 2 for DAP, and 272, 276, and 535 for numbers of image frames in diagnostic, therapeutic, and both procedures in the same session, respectively. The proportions of fluoroscopy in DAP for the procedures were 11.4%, 50.5%, and 36.1%, respectively, for the three groups. The mean DAP for each 3-dimensional rotational angiographic acquisition was 19.2 +/- 3.2 Gy-cm 2 . On average, rotational angiography was used 1.4 +/- 0.6 times/session (range, 1-4; n = 580). Radiation dose in our study as measured by DAP, fluoroscopy time and image frames did not differ significantly from other reported DRL studies for cerebral angiography, and DAP was lower with fewer angiographic image frames for embolization. A national registry of radiation-dose data is a necessary next step to refine the dose reference level.

  16. A characteristic of angiographic cone-beam CT

    International Nuclear Information System (INIS)

    Takase, Tadashi; Take, Toshio; Nakazawa, Yasuo; Kinouchi, Katsunori

    2009-01-01

    Angiographic cone-beam CT, called DynaCT by SIEMENS, is a 3D imaging tool reconstructed from projection data by a rotational C-arm with a flat panel detector. It can visualize low-contrast objects such as soft tissue or small vessels as well as high-contrast structures such as enhanced vessels or bone. We need to understand its image characteristics and dose distribution during 200 degree rotation around a patient. In this research, we evaluated fundamental characteristics and dose effectiveness for optimized clinical images. DynaCT, including soft tissue information and isochronal voxel data along the z-axis, could provide enough CT-like image quality for interventional radiology (IVR) use. In addition, evaluation of accumulated dose distribution helped us to predict and avoid the occurrence of radiodermatitis. Thus, DynaCT is useful as a support and navigation tool for IVR. (author)

  17. Fluoroscopically guided placement of self-expandable metallic stents and stent-grafts in the treatment of acute malignant colorectal obstruction.

    Science.gov (United States)

    Kim, Honsoul; Kim, Seung Hyoung; Choi, Sun Young; Lee, Kwang-Hun; Won, Jong Yoon; Lee, Do Yun; Lee, Jong Tae

    2008-12-01

    To evaluate the technical feasibility and clinical effectiveness of fluoroscopically guided placement of self-expandable metallic stents and stent-grafts for acute malignant colorectal obstruction. Radiologic images and clinical reports of 42 patients (22 men, 20 women; age range, 28-93 years; median age, 65.5 years) who underwent fluoroscopically guided colorectal stent insertion without endoscopic assistance for acute malignant obstruction were reviewed retrospectively. Eighteen patients received bare stents as a bridge to surgery. Twenty-four patients received 27 insertions of either a bare stent (n = 15) or a stent-graft (n = 12) for palliation. The obstruction was located in the rectum (n = 8), sigmoid (n = 17), descending colon (n = 8), splenic flexure (n = 3), and transverse colon (n = 6). Clinical success, defined as more than 50% dilatation of the stent with subsequent symptomatic improvement, was achieved in 41 of the 42 patients (98%). No major procedure-related complications occurred. Minor complications occurred in eight of the 45 procedures (18%). No perioperative mortalities occurred within 1 month after surgery. In the palliative group, the median stent patency was 62 days (range, 0-1,014 days). There was no statistically significant difference in stent patency between the bare stents (range, 0-855 days; median, 68 days) and stent-grafts (range, 1-1,014 days; median, 81 days). Fluoroscopically guided placement of self-expandable metallic stents and stent-grafts for the relief of acute malignant colorectal obstruction was technically feasible without endoscopic assistance-even in lesions proximal to the splenic flexure and transverse colon-and clinically effective in both bridge to surgery and palliative management.

  18. Intraoperative digital angiography: Peripheral vascular applications

    International Nuclear Information System (INIS)

    Bell, K.; Reifsteck, J.E.; Binet, E.F.; Fleisher, H.J.

    1986-01-01

    Intraoperative digital angiography is the procedure of choice for the peripheral vascular surgeon who wishes to evaluate his results before terminating anesthesia. Two operating suites at the John L. McClellan Memorial Veterans Hospital are equipped with permanent ceiling-mounted Philips C-arm fluoroscopes and share an ADAC 4100 digital angiographic system. In the last 18 months, 40 peripheral vascular intraoperative digital angiographic procedures have been performed, in all but two cases using direct arterial puncture. In 65% of cases, the intraoperative study showed no significant abnormality. In 12.5%, minor abnormalities not requiring reoperation were seen. In 22.5% of cases, the intraoperative digital angiogram revealed a significant abnormality requiring immediate operative revision. None of the patients who underwent reoperation experienced postoperative sequelae. Intraoperative digital angiography is useful in identifying complications of peripheral vascular operations

  19. Stent placement under fluoroscopic monitoring and endoscopic direct vision for the treatment of malignant gastroduodenal obstruction: a report of 47 cases

    International Nuclear Information System (INIS)

    Zhang Baoyang; Li Weiping; Jiang Haosheng; Liu Shiyi; Hu Yi

    2009-01-01

    Objective: To discuss the operational technique and clinical effect of metallic stent placement in treating malignant gastroduodenal obstruction. Methods: Metallic stent placement under fluoroscopic monitoring and endoscopic direct vision was performed in 47 patients with malignant gastroduodenal obstruction. A total of 54 metallic stents was used. Results: The procedure was successfully completed in all 47 patients. During the follow-up period, all the patients could take liquid or ordinary diet and were markedly relived of vomiting. The living quality was much improved and no serious complications occurred. Conclusion: Under fluoroscopic monitoring and endoscopic direct vision, stent placement is a safe, effective, technically-simple and time-saving procedure for the treatment of malignant gastroduodenal obstruction with less sufferings to the patient. Therefore, it is definitely worth popularizing this technique in clinical practice. (authors)

  20. Robust fluoroscopic tracking of fiducial markers: exploiting the spatial constraints

    International Nuclear Information System (INIS)

    Li Rui; Sharp, Gregory

    2013-01-01

    Two new fluoroscopic fiducial tracking methods that exploit the spatial relationship among the multiple implanted fiducial to achieve fast, accurate and robust tracking are proposed in this paper. The spatial relationship between multiple implanted markers are modeled as Gaussian distributions of their pairwise distances over time. The means and standard deviations of these distances are learned from training sequences, and pairwise distances that deviate from these learned distributions are assigned a low spatial matching score. The spatial constraints are incorporated in two different algorithms: a stochastic tracking method and a detection based method. In the stochastic method, hypotheses of the ‘true’ fiducial position are sampled from a pre-trained respiration motion model. Each hypothesis is assigned an importance value based on image matching score and spatial matching score. Learning the parameters of the motion model is needed in addition to learning the distribution parameters of the pairwise distances in the proposed stochastic tracking approach. In the detection based method, a set of possible marker locations are identified by using a template matching based fiducial detector. The best location is obtained by optimizing the image matching score and spatial matching score through non-serial dynamic programming. In this detection based approach, there is no need to learn the respiration motion model. The two proposed algorithms are compared with a recent work using a multiple hypothesis tracking (MHT) algorithm which is denoted by MHT, Tang et al (2007 Phys. Med. Biol. 52 4081–98). Phantom experiments were performed using fluoroscopic videos captured with known motion relative to an anthropomorphic phantom. The patient experiments were performed using a retrospective study of 16 fluoroscopic videos of liver cancer patients with implanted fiducials. For the motion phantom data sets, the detection based approach has the smallest tracking error (

  1. Superselective angiographic findings and the blood supply in the cases of avascular necrosis of the femoral head: a preliminary study

    International Nuclear Information System (INIS)

    Zhou Weisheng; Wang Fangjun; Ling Yisheng; Zhao Tianqing

    2003-01-01

    Objective: To study the superselective angiographic findings and blood supply in the case of avascular necrosis of the femoral head (ANFH). Methods: One hundred and sixty five patients (214 hips) with ANFH proved by clinic and radiology underwent superselective angiography and DSA findings were retrospectively studied. Results: Abnormal angiographic findings of the medial circumflex artery and its branches, with or without other abnormal vascularities, could be obtained in 162 hips out of 211 (98.6%). Angiographic findings of ANFH were the followings: abnormal superior and inferior capsular branch of the medial circumflex artery, especially the former one; abnormalities in the ascending branch of lateral circumflex artery; opacification of the femoral head and neck in the parenchymal phase of DSA; revasculization of the small arterial branches or a hypervascular area surrounding the necrotic lesions; anastomosis between the medial circumflex artery and the inferior and superior gluteal arteries; and the venous stasis. Conclusion: Morphological changes of blood vessels in ANFH are demonstrated by superselective angiography, in which the medial circumflex artery and its branches are mostly involved, or in some cases, accompanied by venous stasis

  2. Early Angiographic Resolution of Cerebral Vasospasm with High Dose Intravenous Milrinone Therapy

    Directory of Open Access Journals (Sweden)

    F. A. Zeiler

    2015-01-01

    Full Text Available Background. Treatment of symptomatic delayed cerebral ischemia (DCI after subarachnoid hemorrhage (SAH is difficult. Recent studies suggest intravenous (IV high dose milrinone as a potential therapy. The timing to angiographic response with this is unclear. Methods. We reviewed the chart of one patient admitted for SAH who developed symptomatic DCI and was treated with high dose IV milrinone. Results. A 66-year-old female was admitted with a Hunt and Hess clinical grade 4, World Federation of Neurological Surgeons (WFNS clinical grade 4, and SAH secondary to a left anterior choroidal artery aneurysm which was clipped. After bleed day 6, the patient developed symptomatic DCI. We planned for angioplasty of the proximal segments. We administered high dose IV milrinone bolus followed by continuous infusion which led to clinical improvement prior to angiography. The angiogram performed 1.5 hours after milrinone administration displayed resolution of the CT angiogram and MRI based cerebral vasospasm such that further intra-arterial therapy was aborted. She completed 6 days of continuous IV milrinone therapy, was transferred to the ward, and subsequently rehabilitated. Conclusions. High dose IV milrinone therapy for symptomatic DCI after SAH can lead to rapid neurological improvement with dramatic early angiographic improvement of cerebral vasospasm.

  3. Sub-clinical assessment of atopic dermatitis severity using angiographic optical coherence tomography

    Science.gov (United States)

    Byers, Robert A.; Maiti, Raman; Danby, Simon G.; Pang, Elaine J.; Mitchell, Bethany; Carré, Matt J.; Lewis, Roger; Cork, Michael J.; Matcher, Stephen J.

    2018-01-01

    Measurement of sub-clinical atopic dermatitis (AD) is important for determining how long therapies should be continued after clinical clearance of visible AD lesions. An important biomarker of sub-clinical AD is epidermal hypertrophy, the structural measures of which often make optical coherence tomography (OCT) challenging due to the lack of a clearly delineated dermal-epidermal junction in AD patients. Alternatively, angiographic OCT measurements of vascular depth and morphology may represent a robust biomarker for quantifying the severity of clinical and sub-clinical AD. To investigate this, angiographic data sets were acquired from 32 patients with a range of AD severities. Deeper vascular layers within skin were found to correlate with increasing clinical severity. Furthermore, for AD patients exhibiting no clinical symptoms, the superficial plexus depth was found to be significantly deeper than healthy patients at both the elbow (p = 0.04) and knee (p<0.001), suggesting that sub-clinical changes in severity can be detected. Furthermore, the morphology of vessels appeared altered in patients with severe AD, with significantly different vessel diameter, length, density and fractal dimension. These metrics provide valuable insight into the sub-clinical severity of the condition, allowing the effects of treatments to be monitored past the point of clinical remission. PMID:29675335

  4. Long-term clinical and angiographic results of Sirolimus-Eluting Stent in Complex Coronary Chronic Total Occlusion Revascularization: the SECTOR registry.

    Science.gov (United States)

    Galassi, Alfredo R; Tomasello, Salvatore D; Costanzo, Luca; Campisano, Maria B; Barrano, Giombattista; Tamburino, Corrado

    2011-10-01

    Drug-eluting stents showed a better angiographic and clinical outcome in comparison with bare metal stent in chronic total occlusions (CTOs) percutaneous revascularization, however, great concerns still remain regarding the rate of restenosis and reocclusion in comparison with nonocclusive lesions. To evaluate angiographic and clinical outcomes after sirolimus-eluting stent (SES) implantation in the setting of a "real world" series of complex CTOs. From January 2006 to December 2008, 172 consecutive patients with 179 CTO lesions were enrolled into registry. Among these, successful recanalization was obtained in 144 lesions (80.4%) with exclusive SES implantation in 104 lesions. The 9-12 months angiographic follow-up was executed in 85.5% of lesions with evidence of angiographic binary restenosis in 16.8% of lesions. Total stent length and number of stent implanted were recognized as independent predictors of restenosis (odds ratio [OR] 4.7, 95% confidence interval [CI] 1.28-107.09, P = 0.02) and (OR 5.8, 95% CI 1.39-23.55, P = 0.01), respectively.The 2-year clinical follow-up showed rates of target lesion revascularization, non-Q wave myocardial infarction, and total major adverse cardiovascular events (MACEs) of 11.1%, 2%, and 13.1%, respectively. Cox proportional-hazard analysis showed diabetes as independent predictor of MACEs (hazard ratio [HR] 4.832; 95% CI, 0.730-0.861; P = 0.028). Data from this registry demonstrate the long-term efficacy and safety of SES implantation after complex CTOs recanalization. ©2011, Wiley Periodicals, Inc.

  5. Quantitative stress-redistribution planar T1-201 scintigraphy: Assessment of the extent of hypoperfused myocardium by relationship to angiographic findings

    International Nuclear Information System (INIS)

    Bassir, R.; Maddahi, J.; Garcia, E.

    1984-01-01

    The size of hypoperfused myocardium (HM) in coronary artery (CA) disease (D) potentially provides a prognostic index that may not be accurately assess by conventional angiographic classification. The authors studied 62 consecutive patients (pts) with planar stress-redistribution T1-201 scintigraphy (T1-201) and coronary arteriography who did not have prior myocardial infarction and achieved 85% predicted maximum heart rate on exercise. Of 62 pts, 42 had CAD (>50% stenosis). For T1-201 quantification of the size of HM, maximum count circumferential profiles of initial distribution and % washout were obtained and compared to previously established normal limits. The area enclosed between the normal limits and the abnormal portion of the pt's profiles represented a quantitative T1-201 jeopardy score (JS). Despite increasing T1-201 JS from 1 to 3 vessel (V) and left-main (LM) D, significant overlap between the different angiographic groups was observed; of 45 pts with mild JS (<300), 14 (31%) had 3VD and/or LMD. The angiographic extent of CAD was also analyzed using a method (CLASS) proposed by Gensini et al based on the CA territory, location and severity of stenosis, and collateral circulation. T1-201 JS correlated significantly with CLASS (r=.78, p<.01). Of the 45 pts with mild JS, only 5 (11%) had severe CLASS score. Thus, the size of the hypoperfused myocardium by quantitative stress- and redistribution T1-201 correlates better with a more complex angiographic estimate of myocardium at risk than conventional 1, 2, and 3 vessel disease classification

  6. CLINICAL AND ANGIOGRAPHIC PROFILE OF PATIENTS WITH COMPLETE HEART BLOCK

    Directory of Open Access Journals (Sweden)

    Kavya Pingali

    2017-05-01

    Full Text Available BACKGROUND The angiographic findings and prognosis of patients with Complete Heart Block (CHB remain unclear. Thus, we aimed to study the clinical profile, risk factors, angiographic distribution and in-hospital outcomes of patients with complete heart block. MATERIALS AND METHODS This was a prospective, single-centred study which included 100 patients who came to the emergency department with CHB. Routine blood investigations including serum electrolytes were done. Coronary angiogram was done and lesions were assessed. Temporary pacemaker was implanted followed by permanent pacemakers in required patients, and in-hospital complications were noted down. RESULTS Commonest age group was above 60 years (75%. The patients were predominantly males. Most common presentation was chest pain (60%; there was regional wall motion abnormality in 30% patients. Degenerative complete heart block was seen in 34% patients, diphtheric myocarditis in 15%, hypokalaemic in 15%, dilated cardiomyopathy in 2%. Of total 53 patients had AV block, 14 had bifascicular block, 23 had LBBB, 6 had RBBB, 3 had Mobitz I and 1 had Mobitz II. Inferior wall myocardial infarction (MI was pervasively present in patients. Temporary pacemakers were implanted in 6 patients and permanent pacemakers in 43 patients. In-hospital outcomes constituted of complication like cardiogenic shock (10% and death (26%. The patients who died either had 80% -90% stenosis in RCA, triple vessel disease, ostioproximal LAD occlusion or diphtheric myocarditis. CONCLUSION Complete heart block was majorly associated with advanced age and inferior wall MI, virtually caused by dominant RCA occlusion. The in-hospital mortality was significantly higher in the patients with CHB.

  7. Long-term Luminal Renarrowing After Successful Elective Coronary Angioplasty of Total Occlusions : A Quantitative Angiographic Analysis

    NARCIS (Netherlands)

    A.G. Violaris (Andonis); R. Melkert (Rein); P.W.J.C. Serruys (Patrick)

    1995-01-01

    textabstractBackground The long-term angiographic outcome after successful dilatation of coronary occlusions remains unclear. The objective of this study was to examine long-term restenosis after successful balloon dilatation of coronary occlusions at a predetermined time interval with quantitative

  8. Characterization of a high-elbow, fluoroscopic electronic portal imaging device for portal dosimetry

    International Nuclear Information System (INIS)

    Boer, J.C.J. de; Visser, A.G.

    2000-01-01

    The application of a newly developed fluoroscopic (CCD-camera based) electronic portal imaging device (EPID) in portal dosimetry is investigated. A description of the EPID response to dose is presented in terms of stability, linearity and optical cross-talk inside the mechanical structure. The EPID has a relatively large distance (41 cm on-axis) between the fluorescent screen and the mirror (high-elbow), which results in cross-talk with properties quite different from that of the low-elbow fluoroscopic EPIDs that have been studied in the literature. In contrast with low-elbow systems, the maximum cross-talk is observed for points of the fluorescent screen that have the largest distance to the mirror, which is explained from the geometry of the system. An algorithm to convert the images of the EPID into portal dose images (PDIs) is presented. The correction applied for cross-talk is a position-dependent additive operation on the EPID image pixel values, with a magnitude that depends on a calculated effective field width. Deconvolution with a point spread function, as applied for low-elbow systems, is not required. For a 25 MV beam, EPID PDIs and ionization chamber measurements in the EPID detector plane were obtained behind an anthropomorphic phantom and a homogeneous absorber for various field shapes. The difference in absolute dose between the EPID and ionization chamber measurements, averaged over the four test fields presented in this paper, was 0.1±0.5% (1 SD) over the entire irradiation field, with no deviation larger than 2%. (author)

  9. Accurate 3D kinematic measurement of temporomandibular joint using X-ray fluoroscopic images

    Science.gov (United States)

    Yamazaki, Takaharu; Matsumoto, Akiko; Sugamoto, Kazuomi; Matsumoto, Ken; Kakimoto, Naoya; Yura, Yoshiaki

    2014-04-01

    Accurate measurement and analysis of 3D kinematics of temporomandibular joint (TMJ) is very important for assisting clinical diagnosis and treatment of prosthodontics and orthodontics, and oral surgery. This study presents a new 3D kinematic measurement technique of the TMJ using X-ray fluoroscopic images, which can easily obtain the TMJ kinematic data in natural motion. In vivo kinematics of the TMJ (maxilla and mandibular bone) is determined using a feature-based 2D/3D registration, which uses beads silhouette on fluoroscopic images and 3D surface bone models with beads. The 3D surface models of maxilla and mandibular bone with beads were created from CT scans data of the subject using the mouthpiece with the seven strategically placed beads. In order to validate the accuracy of pose estimation for the maxilla and mandibular bone, computer simulation test was performed using five patterns of synthetic tantalum beads silhouette images. In the clinical applications, dynamic movement during jaw opening and closing was conducted, and the relative pose of the mandibular bone with respect to the maxilla bone was determined. The results of computer simulation test showed that the root mean square errors were sufficiently smaller than 1.0 mm and 1.0 degree. In the results of clinical application, during jaw opening from 0.0 to 36.8 degree of rotation, mandibular condyle exhibited 19.8 mm of anterior sliding relative to maxillary articular fossa, and these measurement values were clinically similar to the previous reports. Consequently, present technique was thought to be suitable for the 3D TMJ kinematic analysis.

  10. Fluoroscopically guided closed reduction and internal fixation of fractures of the lateral portion of the humeral condyle: prospective clinical study of the technique and results in ten dogs.

    Science.gov (United States)

    Cook, J L; Tomlinson, J L; Reed, A L

    1999-01-01

    To report a technique for fluoroscopically guided closed reduction with internal fixation of fractures of the lateral portion of the humeral condyle (FLHC) and determine the long-term results in 10 clinical cases. Prospective clinical case study. Ten dogs with 11 fractures. Fractures of the lateral portion of the humeral condyle were stabilized with transcondylar screws and Kirschner wires. Closed reduction and implant placement were achieved using intraoperative fluoroscopic guidance. After fracture repair, postoperative radiographs were evaluated for articular alignment and implant placement. Dogs were evaluated after surgery by means of lameness scores, elbow range of motion (ROM), radiographic assessment, and owner evaluation of function. Postoperative reduction was considered anatomic in 6 fractures with all other fractures having ROM values between affected and unaffected elbows. All of the dogs in this study regained 90-100% of full function, based on owner assessment. Fluoroscopic guidance for closed reduction and internal fixation of FLHC in dogs is an effective technique.

  11. Should incidental asymptomatic angiographic stenoses and occlusions be treated in patients with peripheral arterial disease?

    LENUS (Irish Health Repository)

    Keeling, Aoife N

    2009-09-01

    The clinical importance of angiographically detected asymptomatic lower-limb stenoses and occlusions is unknown. This study aims to (i) assess the clinical outcome of asymptomatic lesions in the lower limb, (ii) identify predictors of clinical deterioration, and (iii) determine which asymptomatic lower-limb lesions should be treated at presentation.

  12. Angiographic Findings and Embolotherapy in Renal Arterial Trauma

    International Nuclear Information System (INIS)

    Sofocleous, Constantinos T.; Hinrichs, Clay; Hubbi, Basil; Brountzos, Elias; Kaul, Sanjeev; Kannarkat, George; Bahramipour, Philip; Barone, Alison; Contractor, Daniel G.; Shah, Tanmaya

    2005-01-01

    Purpose To evaluate the angiographic findings and embolotherapy in the management of traumatic renal arterial injury Methods This is a retrospective review of 22 patients with renal trauma who underwent arteriography and percutaneous embolization from December 1995 to January 2002. Medical records, imaging studies and procedural reports were reviewed to assess the type of injury, arteriographic findings and immediate embolization results. Long-term clinical outcome was obtained by communication with the trauma physicians and by clinical chart review.Results Arteriography was performed in 125 patients admitted to a State Trauma Center with suspected internal bleeding. Renal arterial injury was documented in 22 and was the result of a motor-vehicle accident (10), auto-pedestrian accident (1), gunshot (4) or stab wounds (6) and a fall (1). Percutaneous renal arterial embolization was undertaken in 22 of 125 (18%) patients to treat extravasation (11), arterial pedicle rupture (5), abnormal arteriovenous (3) or arteriocalyceal (2) communication and pseudoaneurysm (3). One of the pseudoaneurysms and one of the arteriovenous fistulae were found in addition to extravasation. All 22 patients (16 men, 6 women) were hemodynamically stable, or controlled during arteriography and embolotherapy. Selective and/or superselective embolization of the abnormal vessels was performed using coils in 9 patients, microcoils in 9 patients and Gelfoam pledgets in 3 patients. In one patient Gelfoam pledgets mixed with polyvinyl alcohol (PVA) particles were used for embolization. Immediate angiographic evidence of hemostasis was demonstrated in all cases. Two initial technical failures were treated with repeat arteriography and embolization. There was no procedure-related death. There was no non-target embolization. One episode of renal abscess after embolization was treated by nephrectomy and 3 patients underwent elective post-embolization nephrectomy to prevent infection. Follow-up ranged

  13. Cerebral Angiographic Findings of Cosmetic Facial Filler-related Ophthalmic and Retinal Artery Occlusion

    OpenAIRE

    Kim, Yong-Kyu; Jung, Cheolkyu; Woo, Se Joon; Park, Kyu Hyung

    2015-01-01

    Cosmetic facial filler-related ophthalmic artery occlusion is rare but is a devastating complication, while the exact pathophysiology is still elusive. Cerebral angiography provides more detailed information on blood flow of ophthalmic artery as well as surrounding orbital area which cannot be covered by fundus fluorescein angiography. This study aimed to evaluate cerebral angiographic features of cosmetic facial filler-related ophthalmic artery occlusion patients. We retrospectively reviewed...

  14. WE-G-207-06: 3D Fluoroscopic Image Generation From Patient-Specific 4DCBCT-Based Motion Models Derived From Physical Phantom and Clinical Patient Images

    International Nuclear Information System (INIS)

    Dhou, S; Cai, W; Hurwitz, M; Rottmann, J; Myronakis, M; Cifter, F; Berbeco, R; Lewis, J; Williams, C; Mishra, P; Ionascu, D

    2015-01-01

    Purpose: Respiratory-correlated cone-beam CT (4DCBCT) images acquired immediately prior to treatment have the potential to represent patient motion patterns and anatomy during treatment, including both intra- and inter-fractional changes. We develop a method to generate patient-specific motion models based on 4DCBCT images acquired with existing clinical equipment and used to generate time varying volumetric images (3D fluoroscopic images) representing motion during treatment delivery. Methods: Motion models are derived by deformably registering each 4DCBCT phase to a reference phase, and performing principal component analysis (PCA) on the resulting displacement vector fields. 3D fluoroscopic images are estimated by optimizing the resulting PCA coefficients iteratively through comparison of the cone-beam projections simulating kV treatment imaging and digitally reconstructed radiographs generated from the motion model. Patient and physical phantom datasets are used to evaluate the method in terms of tumor localization error compared to manually defined ground truth positions. Results: 4DCBCT-based motion models were derived and used to generate 3D fluoroscopic images at treatment time. For the patient datasets, the average tumor localization error and the 95th percentile were 1.57 and 3.13 respectively in subsets of four patient datasets. For the physical phantom datasets, the average tumor localization error and the 95th percentile were 1.14 and 2.78 respectively in two datasets. 4DCBCT motion models are shown to perform well in the context of generating 3D fluoroscopic images due to their ability to reproduce anatomical changes at treatment time. Conclusion: This study showed the feasibility of deriving 4DCBCT-based motion models and using them to generate 3D fluoroscopic images at treatment time in real clinical settings. 4DCBCT-based motion models were found to account for the 3D non-rigid motion of the patient anatomy during treatment and have the potential

  15. Cognitive deficits after aneurysmal and angiographically negative subarachnoid hemorrhage : Memory, attention, executive functioning, and emotion recognition

    NARCIS (Netherlands)

    Buunk, Anne M; Groen, Rob J M; Veenstra, Wencke S; Metzemaekers, Joannes; van der Hoeven, Johannes H; van Dijk, J Marc C; Spikman, Jacoba M

    2016-01-01

    OBJECTIVE: The authors' aim was to investigate cognitive outcome in patients with aneurysmal and angiographically negative subarachnoid hemorrhage (aSAH and anSAH), by comparing them to healthy controls and to each other. Besides investigating cognitive functions as memory and attention, they

  16. Four-dimensional treatment planning and fluoroscopic real-time tumor tracking radiotherapy for moving tumor

    International Nuclear Information System (INIS)

    Shirato, Hiroki; Shimizu, Shinichi; Kitamura, Kei; Nishioka, Takeshi; Kagei, Kenji; Hashimoto, Seiko; Aoyama, Hidefumi; Kunieda, Tatsuya; Shinohara, Nobuo; Dosaka-Akita, Hirotoshi; Miyasaka, Kazuo

    2000-01-01

    Purpose: To achieve precise three-dimensional (3D) conformal radiotherapy for mobile tumors, a new radiotherapy system and its treatment planning system were developed and used for clinical practice. Methods and Materials: We developed a linear accelerator synchronized with a fluoroscopic real-time tumor tracking system by which 3D coordinates of a 2.0-mm gold marker in the tumor can be determined every 0.03 second. The 3D relationships between the marker and the tumor at different respiratory phases are evaluated using CT image at each respiratory phase, whereby the optimum phase can be selected to synchronize with irradiation (4D treatment planning). The linac is triggered to irradiate the tumor only when the marker is located within the region of the planned coordinates relative to the isocenter. Results: The coordinates of the marker were detected with an accuracy of ± 1 mm during radiotherapy in the phantom experiment. The time delay between recognition of the marker position and the start or stop of megavoltage X-ray irradiation was 0.03 second. Fourteen patients with various tumors were treated by conformal radiotherapy with a 'tight' planning target volume (PTV) margin. They were surviving without relapse or complications with a median follow-up of 6 months. Conclusion: Fluoroscopic real-time tumor tracking radiotherapy following 4D treatment planning was developed and shown to be feasible to improve the accuracy of the radiotherapy for mobile tumors

  17. Clinical-angiographic correlations in 132 patients with megadolichovertebrobasilar anomaly

    Energy Technology Data Exchange (ETDEWEB)

    Resta, M; Gentile, M A; Di Cuonzo, F; Vinjau, E; Brindicci, D; Carella, A

    1984-05-01

    We have found numerous case reports, but no systematic study of the megadolichovertebrobasilar anomaly (MDVBA). The purpose of this paper is to evaluate the relationships between arterial shifts of the vertebro-basilar system and neurological findings in the posterios fossa in our series of 132 cases. We found a high percentage (77.3%) of angiographic-clinical correlations having evaluated the arterial shifts, measured in mm, of the vertebro basilar system in a frontal and a sagittal plane and concluded that the greater the degree of dislocation, the greater the number of Istituto di Radiologia Universita degli studi of Bari, positive cases. Nevertheless it is not possible to predetermine the presence of particular neurosymptomathology related to arterial dislocation degrees.

  18. Radioembolization with 90Y Microspheres: Angiographic and Technical Considerations

    International Nuclear Information System (INIS)

    Lewandowski, Robert J.; Sato, Kent T.; Atassi, Bassel; Ryu, Robert K.; Nemcek, Albert A.; Kulik, Laura; Geschwind, Jean-Francois; Murthy, Ravi; Rilling, William; Liu, David; Bester, Lourens; Bilbao, Jose Ignacio; Kennedy, Andrew S.; Omary, Reed A.; Salem, Riad

    2007-01-01

    The anatomy of the mesenteric system and the hepatic arterial bed has been demonstrated to have a high degree of variation. This is important when considering pre-surgical planning, catheterization, and trans-arterial hepatic therapies. Although anatomical variants have been well described, the characterization and understanding of regional hepatic perfusion in the context of radioembolization have not been studied with great depth. The purpose of this review is to provide a thorough discussion and detailed presentation of the angiographic and technical aspects of radioembolization. Normal vascular anatomy, commonly encountered variants, and factors involved in changes to regional perfusion in the presence of liver tumors are discussed. Furthermore, the principles described here apply to all liver-directed transarterial therapies

  19. A spontaneous pre-anastomotic occlusion does not necessarily impair forearm native dialysis fistulas: echo-Doppler, 3D MR angiographic and digital subtraction angiographic imaging.

    Science.gov (United States)

    Verbeeck, N; Pillet, J C; Prospert, E; McLntyre, D; Lamy, S

    2013-01-01

    Renal transplantation is the choice treatment of end-stage renal disease. When it is not indicated or not immediately feasible, hemodialysis must be performed, preferably via a native arteriovenous fistula in the forearm. A pre-anastomotic occlusion of this type of fistula is often accompanied by a thrombosis of its draining vein. In some instances, the venous segment may remain permeable thanks to the development of arterial collateral pathways and may even allow efficient dialysis without any clinical syndrome of distal steal. We present the echo-Doppler, magnetic and angiographic characteristics of three of these collateralized shunts that have remained functional, in one of the cases following a percutaneous dilation.

  20. Quantitative 4D Transcatheter Intraarterial Perfusion MR Imaging as a Method to Standardize Angiographic Chemoembolization Endpoints

    Science.gov (United States)

    Jin, Brian; Wang, Dingxin; Lewandowski, Robert J.; Ryu, Robert K.; Sato, Kent T.; Larson, Andrew C.; Salem, Riad; Omary, Reed A.

    2011-01-01

    PURPOSE We aimed to test the hypothesis that subjective angiographic endpoints during transarterial chemoembolization (TACE) of hepatocellular carcinoma (HCC) exhibit consistency and correlate with objective intraprocedural reductions in tumor perfusion as determined by quantitative four dimensional (4D) transcatheter intraarterial perfusion (TRIP) magnetic resonance (MR) imaging. MATERIALS AND METHODS This prospective study was approved by the institutional review board. Eighteen consecutive patients underwent TACE in a combined MR/interventional radiology (MR-IR) suite. Three board-certified interventional radiologists independently graded the angiographic endpoint of each procedure based on a previously described subjective angiographic chemoembolization endpoint (SACE) scale. A consensus SACE rating was established for each patient. Patients underwent quantitative 4D TRIP-MR imaging immediately before and after TACE, from which mean whole tumor perfusion (Fρ) was calculated. Consistency of SACE ratings between observers was evaluated using the intraclass correlation coefficient (ICC). The relationship between SACE ratings and intraprocedural TRIP-MR imaging perfusion changes was evaluated using Spearman’s rank correlation coefficient. RESULTS The SACE rating scale demonstrated very good consistency among all observers (ICC = 0.80). The consensus SACE rating was significantly correlated with both absolute (r = 0.54, P = 0.022) and percent (r = 0.85, P SACE rating scale demonstrates very good consistency between raters, and significantly correlates with objectively measured intraprocedural perfusion reductions during TACE. These results support the use of the SACE scale as a standardized alternative method to quantitative 4D TRIP-MR imaging to classify patients based on embolic endpoints of TACE. PMID:22021520

  1. The effect of barium temperature on esophageal and castric motility in dogs: a fluoroscopic study

    International Nuclear Information System (INIS)

    Eville, P.; Ackerman, N.

    1984-01-01

    The influence of barium temperature on canine esophageal transit time and gastric motility were studied fluoroscopically. Micropulverized barium sulfate (30% wt/vol) at 35°F, 70°F, and 100°F was given orally to each of five dogs with a minimum of two hours between each temperature. Esophageal transit times ranged from 4 to 9.67 seconds, and gastric contractions average four per minute. Barium temperature had no significant effect on either esophageal transit time or gastric motility

  2. SU-E-J-01: 3D Fluoroscopic Image Estimation From Patient-Specific 4DCBCT-Based Motion Models

    International Nuclear Information System (INIS)

    Dhou, S; Hurwitz, M; Lewis, J; Mishra, P

    2014-01-01

    Purpose: 3D motion modeling derived from 4DCT images, taken days or weeks before treatment, cannot reliably represent patient anatomy on the day of treatment. We develop a method to generate motion models based on 4DCBCT acquired at the time of treatment, and apply the model to estimate 3D time-varying images (referred to as 3D fluoroscopic images). Methods: Motion models are derived through deformable registration between each 4DCBCT phase, and principal component analysis (PCA) on the resulting displacement vector fields. 3D fluoroscopic images are estimated based on cone-beam projections simulating kV treatment imaging. PCA coefficients are optimized iteratively through comparison of these cone-beam projections and projections estimated based on the motion model. Digital phantoms reproducing ten patient motion trajectories, and a physical phantom with regular and irregular motion derived from measured patient trajectories, are used to evaluate the method in terms of tumor localization, and the global voxel intensity difference compared to ground truth. Results: Experiments included: 1) assuming no anatomic or positioning changes between 4DCT and treatment time; and 2) simulating positioning and tumor baseline shifts at the time of treatment compared to 4DCT acquisition. 4DCBCT were reconstructed from the anatomy as seen at treatment time. In case 1) the tumor localization error and the intensity differences in ten patient were smaller using 4DCT-based motion model, possible due to superior image quality. In case 2) the tumor localization error and intensity differences were 2.85 and 0.15 respectively, using 4DCT-based motion models, and 1.17 and 0.10 using 4DCBCT-based models. 4DCBCT performed better due to its ability to reproduce daily anatomical changes. Conclusion: The study showed an advantage of 4DCBCT-based motion models in the context of 3D fluoroscopic images estimation. Positioning and tumor baseline shift uncertainties were mitigated by the 4DCBCT

  3. Angiographic differentiation of the forms of truncus arteriosis communis and their prognostic significance

    International Nuclear Information System (INIS)

    Schumacher, G.; Schreiber, R.; Lorenz, H.P.; Sebening, W.; Meisner, H.; Sebening, F.; Buehlmeyer, K.; Deutsches Herzzentrum Muenchen des Freistaates Bayern

    1986-01-01

    To decisively improve the life expectancy of children having a truncus arteriosus communis, early surgical intervention during the first year is necessary. As a prerequisite for a successful intervention, a precise diagnosis must be made including angiographic differentiation of the form of the truncus arteriosus communis and possible associated cardiovascular malformations must be established; these constitute important operation hazards and can determine the ultimate success of the intervention. (orig.) [de

  4. Angiographic diagnosis of the prehepatic portal hypertension

    International Nuclear Information System (INIS)

    Carnevali, G.; Brambilla, G.

    1981-01-01

    After the experience gained in the examination of more than 400 patients with portal hypertension, one can say that thrombosis is a factor not to be neglected. It appeared in 25% of all cases, in 50% of all cases as a cause of liver cirrhosis. The representation of the vena coeliaca mesentenica is essential for a reliable detection of thrombosis. Splenoportography is less frequently applied due to the known contraindications and is restricted to more demanding and complex problems. The detection of thrombotic changes is also important because such areas prohibit surgical measures such as by-passes. Also important is the preventive discovery of a portal thrombosis in the course of a complicated, bleeding liver cirrhosis. A pre-operative angiographic diagnosis is necessary in planned portocaval shunt procedures of cirrholic liver alterations. The surgeon has to know beforehand whether pyle thrombosis can be excluded or detected. In the latter case, a thrombotectomy has to be performed, which, however, does not impede good treatment results. (orig./MG) [de

  5. Angiographic diagnosis of the prehepatic portal hypertension

    Energy Technology Data Exchange (ETDEWEB)

    Carnevali, G; Brambilla, G

    1981-01-01

    After the experience gained in the examination of more than 400 patients with portal hypertension, one can say that thrombosis is a factor not to be neglected. It appeared in 25% of all cases and in 50% of all cases as a cause of liver cirrhosis. The representation of the vena coeliaca mesentenica is essential for a reliable detection of thrombosis. Splenoportography is less frequently applied due to the known contraindications and is restricted to more demanding and complex problems. The detection of thrombotic changes is also important because such areas prohibit surgical measures such as by-passes. Also important is the preventive discovery of a portal thrombosis in the course of a complicated, bleeding liver cirrhosis. A pre-operative angiographic diagnosis is necessary in planned portocaval shunt procedures of cirrholic liver alterations. The surgeon has to know beforehand whether pyle thrombosis can be excluded or detected. In the latter case, a thrombotectomy has to be performed, which, however, does not impede good treatment results.

  6. The angiographic demonstration of hepatic vein obstruction

    International Nuclear Information System (INIS)

    Zu Maoheng; Xu Hao; Li Guojun; Gu Yuming; Wei Ning; Wang Cheng; Xu Wei

    2004-01-01

    Objective: To evaluate the angiographic feature of hepatic vein obstruction. Methods Forty-five patients (male 23, female 22, age 9-54 years) suffered from hepatic vein obstruction. The inferior vena cavography and the hepatic venography were performed in all cases. Results: IVC was free in 37 patients with hepatic vein obstruction, both IVC and HV were obstructed in 8 patients. The local or long stenosis of IVC was found in 31 inferior vena cavography. The diameter of IVC was normal in 12 patients. The sign of membranous dome was found in hepatic vein orifice in 5 cases and in accessory hepatic vein orifice in 4 cases. Intrahepatic venous collaterals were found in 45 cases. Conclusion: Hepatic vein obstruction can be reproached primarily in inferior vena cavography, the membranous dome is a direct sign of membranous obstruction of HV and AHV in inferior vena cavography. The selected hepatic venography can provide reliable evidence to diagnose hepatic vein obstruction

  7. Angiographic manifestation and transcatheter arterial embolization of proper esophageal artery in hemoptysis

    International Nuclear Information System (INIS)

    Jiang Sen; Zhu Xiaohua; Sun Xiwen; Zhi Wenxiang; Jie Bing; You Zhengqian; Yu Dong; Peng Gang

    2008-01-01

    Objective: To investigate the angiographic manifestation of the proper esophageal artery (PEA), the high risk factors for the presence of the anomalous PEA in hemoptysis and to evaluate the safety of transcatheter arterial embolization (TAE) of the PEA using gelatin sponge (GS). Methods: Selective esophageal arteriography was performed in forty-three patients with hemoptysis, including 15 cases of pulmonary tuberculosis, 18 cases of bronchiectasis, 7 cases of posttuberculous bronchiectasis and three cases of lung cancer. One case experienced failure of bronchial arterial embolization. The angiographic manifestation of the PEAs was studied. The complications of the procedure and clinical results were observed in the patients who underwent TAE using GS. Results: Thirty-nine PEAs were catheterized selectively in 37 patients (86.0%). Eighteen anomalous PEAs (46.2%) were catheterized selectively in 17 patients (45.9%). The anomalous PEAs showed tortuosity, dilatation, hyperplasia, shunting with pulmonary artery and anastomosis with the bronchial artery. All lesions involved basal segment of inferior pulmonary lobar. Bronchiectasis was the most frequent disease for PEA abnormality. No complications occurred and satisfactory curative effect was achieved with TAE of the anomalous PEAs. Conclusions: It is necessary to perform selective proper esophageal arteriography when the lesion involves basal segment of inferior pulmonary lobar in hemoptysis. Supplemental TAE of the anomalous PEA using GS is safe and valuable in the management of hemoptysis. (authors)

  8. Clinical presentations and MRI findings of angiographically occult vascular malformations

    International Nuclear Information System (INIS)

    Kida, Yoshihisa; Kobayashi, Tatsuya; Tanaka, Takayuki; Oyama, Hirofumi; Iwakoshi, Takayasu

    1994-01-01

    Various clinical features as well as MRI findings of AOVM (angiographically occult vascular malformation) were studied. Amongst out patients, since January 1988, there have been 30 cases of symptomatic AOVM (20 males, 10 females) including 4 cases with multiple lesions. The age ranged from 3 to 60 years of age, with a mean of 33.4 years. The locations of symptomatic lesions were in the cerebral hemisphere (15), the thalamus (4), the brain stem (8) and in the cerebellum (3). The initial presentations of these 30 cases were either by hemorrhage (18), convulsive seizure (9) or by progressive neurological deficits (3). The initial presentation was not related to the patient's age and the size of the lesion, but apparently related to the location of AOVM. Most of the lesions in the cerebral hemisphere presented seizures, but all of the lesions in the thalamus, the brain stem and the cerebellum disclosed hemorrhage as an initial presentation. In fact it was noticed that brain stem lesions tend to cause repetitive hemorrhage in a relatively short period. AOVM lesions were clearly visualized with T2-weighted MRI images, consisting of high intensity cores with surrounding low intensity rims. Most of the symptomatic lesions were partially enhanced by Gd-DTPA with varied intensity. Dynamic changes in size and enhancement pattern on MRI were occasionally seen, usually accompanied with episodes such as hemorrhage or neurological deterioration. Although AOVMs were angiographically negative some strands indicating draining veins were observed on MRI in several cases. In contrast, none of the nonsymptomatic lesions (22 lesions) demonstrated enhancement effects with Gd-DTPA. (author)

  9. Estimation of lung shunt fraction from simultaneous fluoroscopic and nuclear images

    Science.gov (United States)

    van der Velden, Sandra; Bastiaannet, Remco; Braat, Arthur J. A. T.; Lam, Marnix G. E. H.; Viergever, Max A.; de Jong, Hugo W. A. M.

    2017-11-01

    Radioembolisation with yttrium-90 (90Y) is increasingly used as a treatment of unresectable liver malignancies. For safety, a scout dose of technetium-99m macroaggregated albumin (99mTc-MAA) is used prior to the delivery of the therapeutic activity to mimic the deposition of 90Y. One-day procedures are currently limited by the lack of nuclear images in the intervention room. To cope with this limitation, an interventional simultaneous fluoroscopic and nuclear imaging device is currently being developed. The purpose of this simulation study was to evaluate the accuracy of estimating the lung shunt fraction (LSF) of the scout dose in the intervention room with this device and compare it against current clinical methods. Methods: A male and female XCAT phantom, both with two respiratory profiles, were used to simulate various LSFs resulting from a scout dose of 150 MBq 99mTc-MAA. Hybrid images were Monte Carlo simulated for breath-hold (5 s) and dynamic breathing (10 frames of 0.5 s) acquisitions. Nuclear images were corrected for attenuation with the fluoroscopic image and for organ overlap effects using a pre-treatment CT-scan. For comparison purposes, planar scintigraphy and mobile gamma camera images (both 300 s acquisition time) were simulated. Estimated LSFs were evaluated for all methods and compared to the phantom ground truth. Results: In the clinically relevant range of 10-20% LSF, hybrid imaging overestimated LSF with approximately 2 percentage points (pp) and 3 pp for the normal and irregular breathing phantoms, respectively. After organ overlap correction, LSF was estimated with a more constant error. Errors in planar scintigraphy and mobile gamma camera imaging were more dependent on LSF, body shape and breathing profile. Conclusion: LSF can be estimated with a constant minor error with a hybrid imaging device. Estimated LSF is highly dependent on true LSF, body shape and breathing pattern when estimated with current clinical methods. The hybrid

  10. Identification of arteries and veins in cerebral angiography fluoroscopic images

    Science.gov (United States)

    Andra Tache, Irina

    2017-11-01

    In the present study a new method for pixels tagging into arteries and veins classes from temporal cerebral angiography is presented. This need comes from the neurosurgeon who is evaluating the fluoroscopic angiography and the magnetic resonance images from the brain in order to locate the fistula of the patients who suffer from arterio-venous malformation. The method includes the elimination of the background pixels from a previous segmentation and the generation of the time intensity curves for each remaining pixel. The later undergo signal processing in order to extract the characteristic parameters needed for applying the k-means clustering algorithm. Some of the parameters are: the phase and the maximum amplitude extracted from the Fourier transform, the standard deviation and the mean value. The tagged classes are represented into images which then are re-classified by an expert into artery and vein pixels.

  11. Operation logic and functionality of automatic dose rate and image quality control of conventional fluoroscopy

    International Nuclear Information System (INIS)

    Lin, Pei-Jan Paul

    2009-01-01

    New generation of fluoroscopic imaging systems is equipped with spectral shaping filters complemented with sophisticated automatic dose rate and image quality control logic called ''fluoroscopy curve'' or ''trajectory''. Such fluoroscopy curves were implemented first on cardiovascular angiographic imaging systems and are now available on conventional fluoroscopy equipment. This study aims to investigate the control logic operations under the fluoroscopy mode and acquisition mode (equivalent to the legacy spot filming) of a conventional fluoroscopy system typically installed for upper-lower gastrointestinal examinations, interventional endoscopy laboratories, gastrointestinal laboratory, and pain clinics.

  12. Closed reduction and fluoroscopic assisted percutaneous pinning of 42 physeal fractures in 37 dogs and 4 cats

    OpenAIRE

    Boekhout-Ta, Christina L; Kim, Stanley E; Corss, Alan R; Pozzi, Antonio; Evans, Richard

    2017-01-01

    OBJECTIVE: To report complications and clinical outcome of dogs and cats that underwent fluoroscopic-assisted percutaneous pinning (FAPP) of physeal fractures. STUDY DESIGN: Retrospective study. ANIMALS: Client-owned dogs (n = 37) and cats (n = 4). MATERIALS AND METHODS: Records (August 2007-August 2014) of physeal fractures treated with FAPP in 3 hospitals were evaluated. Data collected included signalment, fracture characteristics (etiology, location, duration, Salter-Harris classi...

  13. Economic evaluation of angiographic interventions including a whole-radiology in- and outpatient care; Wirtschaftliche Evaluation angiographischer Interventionen einschliesslich einer radiologischen stationaeren und ambulanten Patientenbetreuung

    Energy Technology Data Exchange (ETDEWEB)

    Nolte-Ernsting, C.; Abel, K.; Krupski, G.; Lorenzen, J.; Adam, G. [Klinik und Poliklinik fuer Diagnostische und Interventionelle Radiologie, Universitaetsklinikum Hamburg-Eppendorf (Germany)

    2006-01-01

    Purpose: To determine the economic efficiency of a whole-radiology in- and outpatient treatment with angiographic interventions performed as the main or sole therapy. Materials and Methods: The calculations represent the data of a university radiology department, including the following angiographic interventions (neuroradiology not considered): Vascular intervention (PTA, stent implantation) of kidneys and extremities, recanalization of hemodialysis access, chemoembolization, diagnostic arterioportal liver CT, port implantation, varicocele embolization, PTCD, percutaneous implantation of biliary stent. First, the different angiographic interventions are categorized with reference to the German DRG system 2005. Considering the example of a university hospital, the individual cost of each intervention is calculated and correlated with reimbursements by G-DRG2005 and so-called ''ambulant operation'' (EBM200plus). With these data, profits and losses are calculated for both in- and outpatient care. Results: Radiologic interventions of inpatients yield a profit in the majority of cases. With a base rate of 2900 Euro, the profits in our university hospital range between -872 Euro and +3411 Euro (mean: +1348 Euro). On the other hand, those angiographic interventions suitable for ''ambulant operation'' generate average profits of +372 Euro, if only direct costs are considered. The data of outpatient radiological interventions average between 381 Euro up to 1612 Euro lower than compared with profits obtained from in patient care. (orig.)

  14. A new self-expanding nitinol stent (Enterprise) for the treatment of wide-necked intracranial aneurysms: initial clinical and angiographic results in 31 aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Weber, Werner; Kuehne, Dietmar [Alfried Krupp Hospital, Department of Radiology and Neuroradiology, Essen (Germany); Bendszus, Martin; Solymosi, Laszlo [University of Wuerzburg, Department of Neuroradiology, Wuerzburg (Germany); Kis, Bernhard [University of Duisburg-Essen, Research Unit, Rheinische Kliniken Essen, Department of Psychiatry and Psychotherapy, Essen (Germany); Boulanger, Thierry [Centre Hospitalier of Luxembourg, Service of Neuroradiology, Luxembourg (Luxembourg)

    2007-07-15

    We report the results of a prospective clinical study using a new self-expanding nitinol stent (Enterprise) designed for the treatment of wide-necked intracranial aneurysms. We treated 31 saccular, wide-necked intracranial aneurysms in 30 patients. Ten aneurysms had recanalized after prior endovascular treatment without a stent, and 21 aneurysms had not been treated before. Stent deployment was successful in all procedures. Additional coil embolization was performed in all aneurysms. Initial complete angiographic occlusion was achieved in 6 aneurysms, a neck remnant was left in 18 aneurysms and there were 7 residual aneurysms. Angiographic follow-up examinations of 30 lesions after 6 months demonstrated 15 complete occlusions, 8 neck remnants and 7 residual aneurysms. One patient refused the 6-month angiographic follow-up. Spontaneous occlusion of the aneurysm had occurred in 14 patients, and 6 aneurysms showed recanalization. Four of these residual aneurysms were retreated. At the 6-month follow-up, 29 parent arteries were unaffected, whereas two parent vessels demonstrated minor asymptomatic narrowing at the stent site. Two patients experienced one or more possible or probable device-related serious adverse events during the 6-month follow-up period. There was no procedural morbidity or mortality at 6 months after the procedure. The reported results demonstrated the safety and feasibility of the Cordis Neurovascular Enterprise stent in the treatment of wide-necked intracranial aneurysms. Initial clinical and angiographic results are favorable. (orig.)

  15. Angiographic Characteristics of Symptomatic Recurrent Disease After Infrainguinal Percutaneous Transluminal Angioplasty

    International Nuclear Information System (INIS)

    Soeder, Heini K.; Manninen, Hannu I.; Matsi, Pekka J.

    1999-01-01

    Purpose: To evaluate the angiographic patterns of clinically manifest recurrent disease after infrainguinal percutaneous transluminal angioplasty (PTA) of stenoses and total occlusions. Methods: Among 326 infrainguinal PTAs on 263 consecutive patients, selective angiography was performed on 61 limbs of 52 patients 1-60 months after the primary intervention because of clinically suspected recurrent disease. Lesion-specific and patient-related factors were analyzed for 75 angiographically confirmed recurrent lesions in 57 limbs of 48 patients. Results: Recurrent disease was more frequently a stenosis when the original target lesion was a stenosis (92%, 44/48) than when the original lesion was a total occlusion (59%, 16/27; p < 0.001). When the original target lesion was a stenosis, the total length of the recurrent disease was longer than that of the original lesion [3.9 ± 3.9 cm (mean ± standard deviation) vs 2.8 ± 2.7 cm; p= 0.03], while in the subgroup of original total occlusions the length of the recurrent lesion was shorter than that of the original occlusion (7.1 ± 5.0 cm vs 9.9 ± 6.9 cm; p0.02). Half the restenoses (22/44) extended beyond one or both ends of the original stenosis and 38% (6/16) of the reocclusions extended beyond the distal end of the original occlusion. Conclusions: The type of recurrent disease depends on the original lesion type and the restenotic lesion frequently extends beyond one or both ends of the original target lesion

  16. Fluoroscopic gating without implanted fiducial markers for lung cancer radiotherapy based on support vector machines

    International Nuclear Information System (INIS)

    Cui Ying; Dy, Jennifer G; Alexander, Brian; Jiang, Steve B

    2008-01-01

    Various problems with the current state-of-the-art techniques for gated radiotherapy have prevented this new treatment modality from being widely implemented in clinical routine. These problems are caused mainly by applying various external respiratory surrogates. There might be large uncertainties in deriving the tumor position from external respiratory surrogates. While tracking implanted fiducial markers has sufficient accuracy, this procedure may not be widely accepted due to the risk of pneumothorax. Previously, we have developed a technique to generate gating signals from fluoroscopic images without implanted fiducial markers using template matching methods (Berbeco et al 2005 Phys. Med. Biol. 50 4481-90, Cui et al 2007b Phys. Med. Biol. 52 741-55). In this note, our main contribution is to provide a totally different new view of the gating problem by recasting it as a classification problem. Then, we solve this classification problem by a well-studied powerful classification method called a support vector machine (SVM). Note that the goal of an automated gating tool is to decide when to turn the beam ON or OFF. We treat ON and OFF as the two classes in our classification problem. We create our labeled training data during the patient setup session by utilizing the reference gating signal, manually determined by a radiation oncologist. We then pre-process these labeled training images and build our SVM prediction model. During treatment delivery, fluoroscopic images are continuously acquired, pre-processed and sent as an input to the SVM. Finally, our SVM model will output the predicted labels as gating signals. We test the proposed technique on five sequences of fluoroscopic images from five lung cancer patients against the reference gating signal as ground truth. We compare the performance of the SVM to our previous template matching method (Cui et al 2007b Phys. Med. Biol. 52 741-55). We find that the SVM is slightly more accurate on average (1-3%) than

  17. Relationship of myocardial hibernation, scar, and angiographic collateral flow in ischemic cardiomyopathy with coronary chronic total occlusion.

    Science.gov (United States)

    Wang, Li; Lu, Min-Jie; Feng, Lei; Wang, Juan; Fang, Wei; He, Zuo-Xiang; Dou, Ke-Fei; Zhao, Shi-Hua; Yang, Min-Fu

    2018-03-07

    The relationship between myocardial viability and angiographic collateral flow is not fully elucidated in ischemic cardiomyopathy (ICM) with coronary artery chronic total occlusion (CTO). We aimed to clarify the relationship between myocardial hibernation, myocardial scar, and angiographic collateral flow in these patients. Seventy-one consecutive ICM patients with 122 CTOs and 652 dysfunctional segments within CTO territories were retrospectively analyzed. Myocardial hibernation (perfusion-metabolism mismatch) and the extent of 18 F-fluorodeoxyglucose (FDG) abnormalities were assessed using 99m Tc-sestamibi and 18 F-FDG imaging. Myocardial scar was evaluated by late gadolinium enhancement (LGE) cardiac magnetic resonance (CMR) imaging. Collateral flow observed on coronary angiography was assessed using Rentrop classification. In these patients, neither the extent nor frequency of myocardial hibernation or scar was related to the status of collateral flow. Moreover, the matching rate in determining myocardial viability was poor between any 2 imaging indices. The extent of 18 F-FDG abnormalities was linearly related to the extent of LGE rather than myocardial hibernation. Of note, nearly one-third (30.4%) of segments with transmural scar still had hibernating tissue. Hibernation and non-transmural scar had higher sensitivity (63.0% and 66.7%) than collateral flow (37.0%) in predicting global functional improvement. Angiographic collateral cannot accurately predict myocardial viability, and has lower sensitivity in prediction of functional improvement in CTO territories in ICM patients. Hence, assessment of myocardial viability with non-invasive imaging modalities is of importance. Moreover, due to the lack of correlation between myocardial hibernation and scar, these two indices are complementary but not interchangeable.

  18. Fluoroscopically guided fallopian tube recanalization with a simplified set of instruments; Durchleuchtungsgesteuerte Eileiter-Rekanalisation mit vereinfachtem Instrumentarium

    Energy Technology Data Exchange (ETDEWEB)

    Schmitz-Rode, T.; Guenther, R.W. [Technische Hochschule Aachen (Germany). Klinik fuer Radiologische Diagnostik; Neulen, J. [Technische Hochschule Aachen (Germany). Frauenklinik fuer gynaekologische Endokrinologie und Reproduktionsmedizin

    2004-10-01

    Purpose: Fluoroscopically guided transcervical fallopian tube recanalization is recognized as an important step in the workup of female infertility. In the present study, a simplified set of recanalization instruments was tested. Materials and Methods: Forty-two women with infertility and sonographically confirmed or suspected uni- or bilateral tubal occlusion were examined. After vaginal placement of a plastic speculum and fixation of a tenaculum, a 4F glide catheter with a 0.89 mm glidewire was advanced transcervically. After documentation of tubal occlusion by hysterosalpingography, the uterotubal junction was catheterized with the same instruments. Under fluoroscopic guidance, the glidewire was negotiated beyond the intramural portion of the tube. Selective salpingography documented the outcome of the recanalization. Results: Hysterosalpingography confirmed tubal occlusions in 26 of 42 patients (in 12 cases unilateral and in 14 cases bilateral). Fallopian tube recanalization was successful in 23 of 26 patients (technical success rate of 88%). The resulting fertility rate was 30% (7/23), without any ectopic pregnancy. Complications such as tubal perforation, infection, or bleeding did not occur. Tubal catheterization was straightforward and smooth in 17/23 cases. For a hyperflexed uterus (6/23), a curved tip of the catheter was helpful in tubal probing. (orig.)

  19. Measuring radiation dose to patients undergoing fluoroscopically-guided interventions

    International Nuclear Information System (INIS)

    Lubis, L E; Badawy, M K

    2016-01-01

    The increasing prevalence and complexity of fluoroscopically guided interventions (FGI) raises concern regarding radiation dose to patients subjected to the procedure. Despite current evidence showing the risk to patients from the deterministic effects of radiation (e.g. skin burns), radiation induced injuries remain commonplace. This review aims to increase the awareness surrounding radiation dose measurement for patients undergoing FGI. A review of the literature was conducted alongside previous researches from the authors’ department. Studies pertaining to patient dose measurement, its formalism along with current advances and present challenges were reviewed. Current patient monitoring techniques (using available radiation dosimeters), as well as the inadequacy of accepting displayed dose as patient radiation dose is discussed. Furthermore, advances in real-time patient radiation dose estimation during FGI are considered. Patient dosimetry in FGI, particularly in real time, remains an ongoing challenge. The increasing occurrence and sophistication of these procedures calls for further advances in the field of patient radiation dose monitoring. Improved measuring techniques will aid clinicians in better predicting and managing radiation induced injury following FGI, thus improving patient care. (paper)

  20. Radiation doses in interventional neuroradiology

    International Nuclear Information System (INIS)

    Theodorakou, C.; Butler, P.; Horrocks, J.A.

    2001-01-01

    Patient radiation doses during interventional radiology (IR) procedures may reach the thresholds for radiation-induced skin and eye lens injuries. This study investigates the radiation doses received by patients undergoing cerebral embolization. Measurements were conducted using thermoluminescent dosimeters. Radiotherapy verification films were used in order to visualise the radiation field. For each procedure the fluoroscopic and digital dose-area product, the fluoroscopic time, the total number of acquired images and entrance-skin dose calculated by the angiographic unit were recorded. In this paper, the skin, eye and thyroid glands doses on a sample of patients are presented. From a preliminary study of 13 patients having undergone cerebral embolization, it was deduced that six of them have received a dose above 1 Gy. Detailed dose data from patients undergoing IR procedures will be collected in the future with the aim of developing a model to allow estimation of the dose prior to the procedure as well as to look at techniques of dose reduction. (author)

  1. Transit-time flow measurement as a predictor of coronary bypass graft failure at one year angiographic follow-up

    DEFF Research Database (Denmark)

    Lehnert, Per; Møller, Christian H; Damgaard, Sune

    2015-01-01

    on graft vessel type, anastomatic configuration, and coronary artery size. RESULTS: Nine hundred eighty-two coronary anastomoses were performed of which 12% had signs of graft failure at one year angiographic follow-up. In internal mammary arteries (IMAs), analysis showed a 4% decrease in graft failure......BACKGROUND: Transit-time flow measurement (TTFM) is a commonly used intraoperative method for evaluation of coronary artery bypass graft (CABG) anastomoses. This study was undertaken to determine whether TTFM can also be used to predict graft patency at one year postsurgery. METHODS: Three hundred...... forty-five CABG patients with intraoperative graft flow measurements and one year angiographic follow-up were analyzed. Graft failure was defined as more than 50% stenosis including the "string sign." Logistic regression analysis was used to analyze the risk of graft failure after one year based...

  2. Fluoroscopic Analysis of Tibial Translation in Anterior Cruciate Ligament Injured Knees With and Without Bracing During Forward Lunge

    Science.gov (United States)

    Jalali, Maryam; Farahmand, Farzam; Mousavi, Seyed Mohammad Ebrahim; Golestanha, Seyed Ali; Rezaeian, Tahmineh; Shirvani Broujeni, Shahram; Rahgozar, Mehdi; Esfandiarpour, Fateme

    2015-01-01

    Background: Despite several studies with different methods, the effect of functional knee braces on knee joint kinematics is not clear. Direct visualization of joint components through medical imaging modalities may provide the clinicians with more useful information. Objectives: In this study, for the first time in the literature, video fluoroscopy was used to investigate the effect of knee bracing on the sagittal plane kinematics of anterior cruciate ligament (ACL) injured patients. Patients and Methods: For twelve male unilateral ACL deficient subjects, the anterior tibial translation was measured during lunge exercise in non-braced and braced conditions. Fluoroscopic images were acquired from the subjects using a digital fluoroscopy system with a rate of 10 fps. The image of each frame was scaled using a calibration coin and analyzed in AutoCAD environment. The angle between the two lines, tangent to the posterior cortexes of the femoral and tibial shafts was measured as the flexion angle. For the fluoroscopic images associated with 0°, 15°, 30°, 45° and 60° knee flexion angles, the relative anterior-posterior configuration of the tibiofemoral joint was assessed by measuring the position of landmarks on the tibia and femur. Results: Results indicated that the overall anterior translations of the tibia during the eccentric (down) and concentric (up) phases of lunge exercise were 10.4 ± 1.7 mm and 9.0 ± 2.2 mm for non-braced, and 10.1 ± 3.4 mm and 7.4 ± 2.5 mm, for braced conditions, respectively. The difference of the tibial anterior-posterior translation behaviors of the braced and non-braced knees was not statistically significant. Conclusion: Fluoroscopic imaging provides an effective tool to measure the dynamic behavior of the knee joint in the sagittal plane and within the limitations of this study, the pure mechanical stabilizing effect of functional knee bracing is not sufficient to control the anterior tibial translation of the ACL deficient

  3. Fluoroscopic Analysis of Tibial Translation in Anterior Cruciate Ligament Injured Knees With and Without Bracing During Forward Lunge.

    Science.gov (United States)

    Jalali, Maryam; Farahmand, Farzam; Mousavi, Seyed Mohammad Ebrahim; Golestanha, Seyed Ali; Rezaeian, Tahmineh; Shirvani Broujeni, Shahram; Rahgozar, Mehdi; Esfandiarpour, Fateme

    2015-07-01

    Despite several studies with different methods, the effect of functional knee braces on knee joint kinematics is not clear. Direct visualization of joint components through medical imaging modalities may provide the clinicians with more useful information. In this study, for the first time in the literature, video fluoroscopy was used to investigate the effect of knee bracing on the sagittal plane kinematics of anterior cruciate ligament (ACL) injured patients. For twelve male unilateral ACL deficient subjects, the anterior tibial translation was measured during lunge exercise in non-braced and braced conditions. Fluoroscopic images were acquired from the subjects using a digital fluoroscopy system with a rate of 10 fps. The image of each frame was scaled using a calibration coin and analyzed in AutoCAD environment. The angle between the two lines, tangent to the posterior cortexes of the femoral and tibial shafts was measured as the flexion angle. For the fluoroscopic images associated with 0°, 15°, 30°, 45° and 60° knee flexion angles, the relative anterior-posterior configuration of the tibiofemoral joint was assessed by measuring the position of landmarks on the tibia and femur. Results indicated that the overall anterior translations of the tibia during the eccentric (down) and concentric (up) phases of lunge exercise were 10.4 ± 1.7 mm and 9.0 ± 2.2 mm for non-braced, and 10.1 ± 3.4 mm and 7.4 ± 2.5 mm, for braced conditions, respectively. The difference of the tibial anterior-posterior translation behaviors of the braced and non-braced knees was not statistically significant. Fluoroscopic imaging provides an effective tool to measure the dynamic behavior of the knee joint in the sagittal plane and within the limitations of this study, the pure mechanical stabilizing effect of functional knee bracing is not sufficient to control the anterior tibial translation of the ACL deficient patients during lunge exercise.

  4. Unilateral renal agenesia in the angiographic material and renovascular hypertension

    Energy Technology Data Exchange (ETDEWEB)

    Stojanov, D.; Lovasic, I.; Dujmovic, M.; Bobinac, D.

    1987-06-01

    Analysis of 1216 abdominal aortographies and selective renovasographies undertaken at the Institute of Radiology, Clinical Hospital Centre Rijeka during the period 1979-1985, was performed. 39 (3,2%) unilateral renal agenesias were established, a percentage that is significantly higher than reported by other authors. Analysis of all angiographic parameters of a single kidney was also worked out. A significanlty high percentage (66,7%) of hypertension was diagnosed in this group. Congenital renal failures make their appearance in the early embryological development and are discovered, if compatible with life, most frequently at an advanced age. Statistical data on the frequency during a lifetime are less reliable because a great number of anomalies are never discovered during a person's life. The etiology of variations and congenital failure of renal arteries is unknown in 90% of the cases, and most of the malformations are without characteristic symptomatology. Since the anatomic relations in anomalous kidney are disturbed, the sign of the disease can develop atypical forms causing frequent errors in diagnosis. The kidney is supplied by numerous lateral branches of the medial sacral artery, i.e. the aorta, during embryological development. Later, some of them degenerate or mutually connect themselves, and the definitive kidney has been usually penetrated by only one artery and one vein on the same side (1). If this is not so, i.e. when the obliterations of caudal metanephogenic arteries are only partially present, then the renal arteries emerge from the iliac or lumbar arteries (2,3). Bilateral renal agenesia is extreme and incompatible with life, and hence of small clinical importance. Unilateral agenesia makes its appearance according to various statistics and authors from the obductional materials in ratio 1:1000 (4,5), clinical ones 1:5000 (6, 7, 8) and the angiographically 1:76(9), more exactly 1:35 cases (10).

  5. Unilateral renal agenesia in the angiographic material and renovascular hypertension

    International Nuclear Information System (INIS)

    Stojanov, D.; Lovasic, I.; Dujmovic, M.; Bobinac, D.

    1987-01-01

    Analysis of 1216 abdominal aortographies and selective renovasographies undertaken at the Institute of Radiology, Clinical Hospital Centre Rijeka during the period 1979-1985, was performed. 39 (3,2%) unilateral renal agenesias were established, a percentage that is significantly higher than reported by other authors. Analysis of all angiographic parameters of a single kidney was also worked out. A significanlty high percentage (66,7%) of hypertension was diagnosed in this group. Congenital renal failures make their appearance in the early embryological development and are discovered, if compatible with life, most frequently at an advanced age. Statistical data on the frequency during a lifetime are less reliable because a great number of anomalies are never discovered during a person's life. The etiology of variations and congenital failure of renal arteries is unknown in 90% of the cases, and most of the malformations are without characteristic symptomatology. Since the anatomic relations in anomalous kidney are disturbed, the sign of the disease can develop atypical forms causing frequent errors in diagnosis. The kidney is supplied by numerous lateral branches of the medial sacral artery, i.e. the aorta, during embryological development. Later, some of them degenerate or mutually connect themselves, and the definitive kidney has been usually penetrated by only one artery and one vein on the same side (1). If this is not so, i.e. when the obliterations of caudal metanephogenic arteries are only partially present, then the renal arteries emerge from the iliac or lumbar arteries (2,3). Bilateral renal agenesia is extreme and incompatible with life, and hence of small clinical importance. Unilateral agenesia makes its appearance according to various statistics and authors from the obductional materials in ratio 1:1000 (4,5), clinical ones 1:5000 (6, 7, 8) and the angiographically 1:76(9), more exactly 1:35 cases (10). (orig.)

  6. Pattern not volume of bleeding predicts angiographic vasospasm in nonaneurysmal subarachnoid hemorrhage.

    Science.gov (United States)

    Raya, Amanda; Zipfel, Gregory J; Diringer, Michael N; Dacey, Ralph G; Derdeyn, Colin P; Rich, Keith M; Chicoine, Michael R; Dhar, Rajat

    2014-01-01

    Spontaneous idiopathic subarachnoid hemorrhage (SAH) with a perimesencephalic bleeding pattern is usually associated with a benign course, whereas a diffuse bleeding pattern has been associated with a higher risk of vasospasm and disability. We evaluated whether volume of bleeding explains this disparity. Pattern and amount of bleeding (by Hijdra and intraventricular hemorrhage scores) were assessed in 89 patients with nonaneurysmal SAH. Outcomes included angiographic vasospasm, delayed cerebral ischemia, and functional outcome at 1 year. Diffuse bleeding was associated with significantly higher Hijdra and intraventricular hemorrhage scores than perimesencephalic SAH, P≤0.003. Angiographic vasospasm was more likely in diffuse versus perimesencephalic SAH (45% versus 27%; odds ratio, 2.9; P=0.08), but adjustment for greater blood burden only partially attenuated this trend (adjusted odds ratio, 2.2; 95% confidence interval, 0.69-7.2; P=0.18); delayed cerebral ischemia was only seen in those with diffuse bleeding. Patients with diffuse bleeding were less likely to be discharged home (68% versus 90%; P=0.01) and tended to have more residual disability (modified Rankin scale, 3-6; 20% versus 6%; P=0.18). Nonaneurysmal SAH can still result in vasospasm and residual disability, especially in those with diffuse bleeding. This disparity is only partially accounted for by greater cisternal or intraventricular blood, suggesting that the mechanism and distribution of bleeding may be as important as the amount of hemorrhage in patients with idiopathic SAH.

  7. An exploration of fluoroscopically guided spinal steroid injections in patients with non-specific exercise-related lower-limb pain

    Directory of Open Access Journals (Sweden)

    Leon Neve

    2010-09-01

    Full Text Available Leon Neve1, John Orchard2, Nathan Gibbs3, Willem van Mechelen4, Evert Verhagen4, Ken Sesel5, Ian Burgess6, Brett Hines61VU University, Amsterdam, The Netherlands; 2School of Public Health, University of Sydney, Sydney, NSW, Australia; 3South Sydney Sports Medicine, Sydney, NSW, Australia; 4EMGO, VU University, Amsterdam, The Netherlands; 5Sydney X-ray Centre, Sydney, NSW, Australia; 6Mater Imaging, Sydney, NSW, AustraliaBackground: Fluoroscopically guided lumbar cortisone injections have been proven useful in cases of lower-limb pain caused by lumbar disc prolapse (with evidence levels ll-1/ll-2. These injections are also sometimes used clinically in sports medicine for patients with non-specific exercise-related lower-limb pain, where no prolapse or other obvious cause of nerve-impingement is diagnosed via magnetic resonance imaging (MRI or computed tomography (CT, even though this treatment scenario has not been adequately studied for this last diagnosis.Objectives: To explore whether fluoroscopically guided transforaminal lumbar cortisone injections may be a valid treatment method for non-specific exercise-related lower-limb pain.Study design: Retrospective case series.Methods: Patients were selected from databases at two sports clinics and divided into two groups: Group D, with back-related lower-limb pain and disc prolapse proven on CT or MR; and Group N, with non-specific exercise-related lower-limb pain. Patients were sent a questionnaire regarding: symptoms, improvement, effect of injections, satisfaction, side effects and other used treatments. Outcomes were compared between Group D and N.Results: 153 patients were eligible for the study (Group D: 93/Group N: 60. Eventually 110 patients responded (Group D: 67/Group N: 43. Twelve percent of Group D and 14% of Group N indicated that the injections had fully cured their symptoms. Altogether, 27% of Group D and 24% of Group N were certain the injections had improved their symptoms in the

  8. SU-E-I-42: Normalized Embryo/fetus Doses for Fluoroscopically Guided Pacemaker Implantation Procedures Calculated Using a Monte Carlo Technique

    Energy Technology Data Exchange (ETDEWEB)

    Damilakis, J; Stratakis, J; Solomou, G [University of Crete, Heraklion (Greece)

    2014-06-01

    Purpose: It is well known that pacemaker implantation is sometimes needed in pregnant patients with symptomatic bradycardia. To our knowledge, there is no reported experience regarding radiation doses to the unborn child resulting from fluoroscopy during pacemaker implantation. The purpose of the current study was to develop a method for estimating embryo/fetus dose from fluoroscopically guided pacemaker implantation procedures performed on pregnant patients during all trimesters of gestation. Methods: The Monte Carlo N-Particle (MCNP) radiation transport code was employed in this study. Three mathematical anthropomorphic phantoms representing the average pregnant patient at the first, second and third trimesters of gestation were generated using Bodybuilder software (White Rock science, White Rock, NM). The normalized embryo/fetus dose from the posteroanterior (PA), the 30° left-anterior oblique (LAO) and the 30° right-anterior oblique (RAO) projections were calculated for a wide range of kVp (50–120 kVp) and total filtration values (2.5–9.0 mm Al). Results: The results consist of radiation doses normalized to a) entrance skin dose (ESD) and b) dose area product (DAP) so that the dose to the unborn child from any fluoroscopic technique and x-ray device used can be calculated. ESD normalized doses ranged from 0.008 (PA, first trimester) to 2.519 μGy/mGy (RAO, third trimester). DAP normalized doses ranged from 0.051 (PA, first trimester) to 12.852 μGy/Gycm2 (RAO, third trimester). Conclusion: Embryo/fetus doses from fluoroscopically guided pacemaker implantation procedures performed on pregnant patients during all stages of gestation can be estimated using the method developed in this study. This study was supported by the Greek Ministry of Education and Religious Affairs, General Secretariat for Research and Technology, Operational Program ‘Education and Lifelong Learning’, ARISTIA (Research project: CONCERT)

  9. SU-E-I-42: Normalized Embryo/fetus Doses for Fluoroscopically Guided Pacemaker Implantation Procedures Calculated Using a Monte Carlo Technique

    International Nuclear Information System (INIS)

    Damilakis, J; Stratakis, J; Solomou, G

    2014-01-01

    Purpose: It is well known that pacemaker implantation is sometimes needed in pregnant patients with symptomatic bradycardia. To our knowledge, there is no reported experience regarding radiation doses to the unborn child resulting from fluoroscopy during pacemaker implantation. The purpose of the current study was to develop a method for estimating embryo/fetus dose from fluoroscopically guided pacemaker implantation procedures performed on pregnant patients during all trimesters of gestation. Methods: The Monte Carlo N-Particle (MCNP) radiation transport code was employed in this study. Three mathematical anthropomorphic phantoms representing the average pregnant patient at the first, second and third trimesters of gestation were generated using Bodybuilder software (White Rock science, White Rock, NM). The normalized embryo/fetus dose from the posteroanterior (PA), the 30° left-anterior oblique (LAO) and the 30° right-anterior oblique (RAO) projections were calculated for a wide range of kVp (50–120 kVp) and total filtration values (2.5–9.0 mm Al). Results: The results consist of radiation doses normalized to a) entrance skin dose (ESD) and b) dose area product (DAP) so that the dose to the unborn child from any fluoroscopic technique and x-ray device used can be calculated. ESD normalized doses ranged from 0.008 (PA, first trimester) to 2.519 μGy/mGy (RAO, third trimester). DAP normalized doses ranged from 0.051 (PA, first trimester) to 12.852 μGy/Gycm2 (RAO, third trimester). Conclusion: Embryo/fetus doses from fluoroscopically guided pacemaker implantation procedures performed on pregnant patients during all stages of gestation can be estimated using the method developed in this study. This study was supported by the Greek Ministry of Education and Religious Affairs, General Secretariat for Research and Technology, Operational Program ‘Education and Lifelong Learning’, ARISTIA (Research project: CONCERT)

  10. Development of a Portable Training Tool for Simulating Visceral Angiographic Procedures for Beginners

    International Nuclear Information System (INIS)

    Yamagami, Takuji; Osuga, Keigo; Yoshimatsu, Rika; Matsumoto, Tomohiro; Miura, Hiroshi; Terayama, Koshi; Anai, Hiroshi; Takahashi, Masahide; Hasebe, Terumitsu; Nishimura, Tsunehiko

    2009-01-01

    The purpose of this study was to evaluate the usefulness of a tool that we developed to simulate performance of visceral angiography to train beginners in the field of splanchnic angiography. Seven residents and two fellows who were rotating within the Division of Interventional Radiology at our institution between June and August 2008 participated in the evaluation of this tool. They had no experience in performing visceral angiography as an operator. Time for selection of arterial branches arising from the celiac axis on the model was measured before and after training. After such training, the participants performed actual visceral angiography as an operator with instructors beside them. Success of the trainees in selecting visceral arterial branches was evaluated in these real-life cases. In the first test using the model, seven of nine trainees (77.8%) succeeded in selecting all required arteries, while the remaining two failed to select all required arteries. After training using the model, all trainees succeeded in selecting all required arteries just before the actual angiographic study. In the actual angiography, the catheter was successfully inserted from the femoral artery and advanced to the superior mesenteric, celiac, splenic, common hepatic, gastroduodenal, and right and left hepatic arteries by all trainees with only two exceptions. In conclusion, this tool is helpful for training beginners in visceral angiographic procedures.

  11. Influence of angiographic collateral circulation on myocardial perfusion in patients with chronic total occlusion of a single coronary artery and no prior myocardial infarction.

    Science.gov (United States)

    Aboul-Enein, Fatma; Kar, Saibal; Hayes, Sean W; Sciammarella, Maria; Abidov, Aiden; Makkar, Raj; Friedman, John D; Eigler, Neal; Berman, Daniel S

    2004-06-01

    The functional role of various angiographic grades for coronary collaterals remains controversial. The aim of this study was to assess the influence of the Rentrop angiographic grading of coronary collaterals on myocardial perfusion in patients with single-vessel chronic total occlusion (CTO) and no prior myocardial infarction (MI). The study included 56 patients with single-vessel CTO and no prior MI who underwent rest-stress myocardial perfusion SPECT and coronary angiography within 6 mo. All patients had angiographic evidence of coronary collaterals. Patients were divided according to the Rentrop classification: Group I had grade 1 or 2 (n = 25) and group II had grade 3 collaterals (n = 31). Group I had a higher frequency of resting regional wall motion abnormalities on left ventriculography (52.6% vs. 19.2% [P = 0.019]). The mean perfusion scores of the overall population showed severe and extensive stress perfusion defects (summed stress score of 14.1 +/- 7.1 and summed difference score of 12.9 +/- 6.9) but minimal resting perfusion defects (summed rest score of 1.0 +/- 2.7). No perfusion scores differed between the 2 groups. The perfusion findings suggested that chronic stunning rather than hibernation is the principal cause of regional wall motion abnormalities in these patients. In the setting of single-vessel CTO and no prior MI, coronary collaterals appear to protect against resting perfusion defects. Excellent angiographic collaterals may prevent resting regional wall motion abnormalities but do not appear to protect against stress-induced perfusion defects.

  12. A study of low-density areas, clinical findings, and angiographic findings in patients with cerebral infarction

    International Nuclear Information System (INIS)

    Saiki, Iwao; Sakai, Yoshiaki; Oikawa, Tadato; Koide, Kohji; Kanaya, Haruyuki.

    1978-01-01

    55 out of 62 patients with cerebral infarction were investigated in terms of CT scan findings, angiographic findings, and clinical symptoms. The results obtained were as follows: 1) The low-density areas of the CT scan findings were classified into the following four types: large hemispheric or lobular --Type I; wedge-shaped --Type II; small --Type III; and lacunar low-density area. --Type IV. 2) Almost all patients with angiographically occlusive findings showed low-density areas of Type I; however, one patient with ICA occlusion revealed only a lacunar low-density area. 3) The patients with lacunar low-density areas showed an angiographically delayed filling of the angular artery and posterior parietal artery of the middle cerebral artery. 4) The relationship between the types of low-density areas and the clinical conscious disorders was not clear. On the other hand, the patients with Type I low-density areas almost all had motor disturbances, while patients with other types of low-density areas showed only 60 - 70% motor disturbances. 5) In patients with speech disorders, total aphasia cases were found in patients with large hemispheric low-density areas on the left side. Although, motor aphasia cases were seen in patients with various low-density areas on the left inferior frontal and precentral gyri, dysarthria cases were found in the patients with several low-density areas on both sides. 6) The localization of lacunar low-density areas seemed to be near the caudate nucleus on the right side and in the putaminal regions on the left side. The mean and the standard deviation of CT numbers in the lacunar low-density areas showed higher values on the right side than on the left side. (author)

  13. [Multidisciplinary protocol for computed tomography imaging and angiographic embolization of splenic injury due to trauma: assessment of pre-protocol and post-protocol outcomes].

    Science.gov (United States)

    Koo, M; Sabaté, A; Magalló, P; García, M A; Domínguez, J; de Lama, M E; López, S

    2011-11-01

    To assess conservative treatment of splenic injury due to trauma, following a protocol for computed tomography (CT) and angiographic embolization. To quantify the predictive value of CT for detecting bleeding and need for embolization. The care protocol developed by the multidisciplinary team consisted of angiography with embolization of lesions revealed by contrast extravasation under CT as well as embolization of grade III-V injuries observed, or grade I-II injuries causing hemodynamic instability and/or need for blood transfusion. We collected data on demographic variables, injury severity score (ISS), angiographic findings, and injuries revealed by CT. Pre-protocol and post-protocol outcomes were compared. The sensitivity and specificity of CT findings were calculated for all patients who required angiographic embolization. Forty-four and 30 angiographies were performed in the pre- and post-protocol periods, respectively. The mean (SD) ISSs in the two periods were 25 (11) and 26 (12), respectively. A total of 24 (54%) embolizations were performed in the pre-protocol period and 28 (98%) after implementation of the protocol. Two and 7 embolizations involved the spleen in the 2 periods, respectively; abdominal laparotomies numbered 32 and 25, respectively, and 10 (31%) vs 4 (16%) splenectomies were performed. The specificity and sensitivity values for contrast extravasation found on CT and followed by embolization were 77.7% and 79.5%. The implementation of this multidisciplinary protocol using CT imaging and angiographic embolization led to a decrease in the number of splenectomies. The protocol allows us to take a more conservative treatment approach.

  14. Angiographic validation of the American College of Cardiology Foundation-the Society of Thoracic Surgeons Collaboration on the Comparative Effectiveness of Revascularization Strategies study.

    Science.gov (United States)

    Chakrabarti, Anjan K; Grau-Sepulveda, Maria V; O'Brien, Sean; Abueg, Cassandra; Ponirakis, Angelo; Delong, Elizabeth; Peterson, Eric; Klein, Lloyd W; Garratt, Kirk N; Weintraub, William S; Gibson, C Michael

    2014-02-01

    The goal of this study was to compare angiographic interpretation of coronary arteriograms by sites in community practice versus those made by a centralized angiographic core laboratory. The study population consisted of 2013 American College of Cardiology-National Cardiovascular Data Registry (ACC-NCDR) records with 2- and 3- vessel coronary disease from 54 sites in 2004 to 2007. The primary analysis compared Registry (NCDR)-defined 2- and 3-vessel disease versus those from an angiographic core laboratory analysis. Vessel-level kappa coefficients suggested moderate agreement between NCDR and core laboratory analysis, ranging from kappa=0.39 (95% confidence intervals, 0.32-0.45) for the left anterior descending artery to kappa=0.59 (95% confidence intervals, 0.55-0.64) for the right coronary artery. Overall, 6.3% (n=127 out of 2013) of those patients identified with multivessel disease at NCDR sites had had 0- or 1-vessel disease by core laboratory reading. There was no directional bias with regard to overcall, that is, 12.3% of cases read as 3-vessel disease by the sites were read as <3-vessel disease by the core laboratory, and 13.9% of core laboratory 3-vessel cases were read as <3-vessel by the sites. For a subset of patients with left main coronary disease, registry overcall was not linked to increased rates of mortality or myocardial infarction. There was only modest agreement between angiographic readings in clinical practice and those from an independent core laboratory. Further study will be needed because the implications for patient management are uncertain.

  15. Correlation of C-Reactive Protein and Cardiac Enzymes with Angiographic Severity of Coronary Artery Disease in Pakistani Patients with Acute Coronary Syndrome.

    Science.gov (United States)

    Saleem, Ayesha; Ali, Azmat

    2017-02-01

    To determine the correlation of C-reactive protein (CRP) levels with the severity of coronary stenosis on angiography and the association of cardiac enzymes with the degree of stenosis in acute coronary syndrome (ACS) patients. Secondly, to compare association of angiographic severity of vascular stenosis with CRP in patients with ST segment elevation myocardial infarction (STEMI) and non-STEMI / Unstable angina (UA). Prospective, descriptive study. Khan Research Laboratories (KRL) Hospital, from October 2014 to March 2015. CRP was measured on diagnosis of ACS in 70 patients. Cardiac enzymes were measured 6 hours after the onset of chest pain. Angiographic scoring for degree of stenosis and number of culprit vessels was done. Two groups consisting of patients with STEMI (group 1) and with NSTEMI/UA (group 2) were made. No correlation was found between CRP levels and angiographic stenosis in patients with ACS (r=0.162, p>0.05). No association was found between eosinophil count and severity of stenosis (p=0.88). Rise of cardiac enzymes and degree of coronary stenosis showed a positive correlation (p Rise in cardiac enzymes still grade high in predicting severity of vascular stenosis than eosinophil count or CRP levels.

  16. The association of elastin gene variants with two angiographic subtypes of polypoidal choroidal vasculopathy.

    Directory of Open Access Journals (Sweden)

    Suiho Yanagisawa

    Full Text Available To compare the association of elastin (ELN gene variants between two different angiographic phenotypes of polypoidal choroidal vasculopathy (PCV.We included 411 treatment-naïve PCV patients and 350 controls in the present study. PCV was classified into two phenotypes (152 Type 1 and 259 Type 2 according to the presence or absence of feeding vessels found in indocyanine-green angiography. Single nucleotide polymorphisms (SNPs in the ELN region including rs868005, rs884843, rs2301995, rs13239907 and rs2856728 were genotyped using TaqMan Genotyping Assays.In the allelic association analyses, rs868005 showed the strongest association with Type 2 PCV (allelic odds ratio 1.56; p = 7.4x10(-6, while no SNP was significantly associated with Type 1 PCV. Genotype association analyses revealed the significant association of rs868005 with Type 2 PCV in log additive model and predominant model (odds ratio 1.75; p = 1.5x10(-6 and odds ratio 1.60; p = 0.0044, respectively, but not with Type 1 PCV. These findings were further corroborated by another control group in the literature.There may be significantly different associations in genetic variants of elastin between two angiographic phenotypes of PCV.

  17. Diagnostic value of the fluoroscopic triggering 3D LAVA technique for primary liver cancer.

    Science.gov (United States)

    Shen, Xiao-Yong; Chai, Chun-Hua; Xiao, Wen-Bo; Wang, Qi-Dong

    2010-04-01

    Primary liver cancer (PLC) is one of the common malignant tumors. Liver acquisition with acceleration volume acquisition (LAVA), which allows simultaneous dynamic enhancement of the hepatic parenchyma and vasculature imaging, is of great help in the diagnosis of PLC. This study aimed to evaluate application of the fluoroscopic triggering 3D LAVA technique in the imaging of PLC and liver vasculature. The clinical data and imaging findings of 38 adults with PLC (22 men and 16 women; average age 52 years), pathologically confirmed by surgical resection or biopsy, were collected and analyzed. All magnetic resonance images were obtained with a 1.5-T system (General Electrics Medical Systems) with an eight-element body array coil and application of the fluoroscopic triggering 3D LAVA technique. Overall image quality was assessed on a 5-point scale by two experienced radiologists. All the nodules and blood vessel were recorded and compared. The diagnostic accuracy and feasibility of LAVA were evaluated. Thirty-eight patients gave high quality images of 72 nodules in the liver for diagnosis. The accuracy of LAVA was 97.2% (70/72), and the coincidence rate between the extent of tumor judged by dynamic enhancement and pathological examination was 87.5% (63/72). Displayed by the maximum intensity projection reconstruction, nearly all cases gave satisfactory images of branches III and IV of the hepatic artery. Furthermore, small early-stage enhancing hepatic lesions and the parallel portal vein were also well displayed. Sequence of LAVA provides good multi-phase dynamic enhancement scanning of hepatic lesions. Combined with conventional scanning technology, LAVA effectively and safely displays focal hepatic lesions and the relationship between tumor and normal tissues, especially blood vessels.

  18. Corrected thrombolysis in myocardial infarction frame counts in diabetic patients with angiographically normal coronary arteries

    International Nuclear Information System (INIS)

    Turkoglu, S.; Ozdemir, M.; Tacoy, G.; Tavil, Y.; Abaci, A.; Timurkaynak, T.; Cengel, A.

    2008-01-01

    Objective was to evaluate corrected thrombolysis in myocardial infarction (TIMI) frame count (CTFC) in patients with angiographically normal coronary arteries and diabetes mellitus, a condition known to be associated with microvascular dysfunction. Patients who underwent coronary angiography in Gazi University Hospital, Ankara, Turkey between January 2000 and January 2005 were studied. Corrected TIMI frame count was left circumflex (Cx) and right coronary arteries (RCA) in 118 diabetic and 122 non-diabetic patients with normal coronary angiogram. The mean CTFC values of the LAD, Cx and the RCA were similar in diabetics and nondiabetics (21.0+-7.5 versus 21.3+-9.6, 23.3+-9.7 versus 23.5+-10.8, 17.9+-6.7 versus 18.7+-7.4 respectively, p>0.05 for all comparisons). In stepwise multivariate linear regression analysis, body surface area had a significant correlation with CTFC of all the 3 coronary arteries. We conclude that CTFC in diabetics and non-diabetics with angiographically normal coronary arteries is similar. Since microvascular disease is an inherent component of diabetes, our finding may reflect the inadequacy of CTFC in predicting microvascular disease in diabetic patients with normal coronary angiograms. (author)

  19. Angiographic analysis of animal model aneurysms treated with novel polyurethane asymmetric vascular stent (P-AVS): feasibility study.

    Science.gov (United States)

    Ionita, Ciprian N; Dohatcu, Andreea; Sinelnikov, Andrey; Sherman, Jason; Keleshis, Christos; Paciorek, Ann M; Hoffmann, K R; Bednarek, D R; Rudin, S

    2009-01-01

    Image-guided endovascular intervention (EIGI), using new flow modifying endovascular devices for intracranial aneurysm treatment is an active area of stroke research. The new polyurethane-asymmetric vascular stent (P-AVS), a vascular stent partially covered with a polyurethane-based patch, is used to cover the aneurysm neck, thus occluding flow into the aneurysm. This study involves angiographic imaging of partially covered aneurysm orifices. This particular situation could occur when the vascular geometry does not allow full aneurysm coverage. Four standard in-vivo rabbit-model aneurysms were investigated; two had stent patches placed over the distal region of the aneurysm orifice while the other two had stent patches placed over the proximal region of the aneurysm orifice. Angiographic analysis was used to evaluate aneurysm blood flow before and immediately after stenting and at four-week follow-up. The treatment results were also evaluated using histology on the aneurysm dome and electron microscopy on the aneurysm neck. Post-stenting angiographic flow analysis revealed aneurysmal flow reduction in all cases with faster flow in the distally-covered case and very slow flow and prolonged pooling for proximal-coverage. At follow-up, proximally-covered aneurysms showed full dome occlusion. The electron microscopy showed a remnant neck in both distally-placed stent cases but complete coverage in the proximally-placed stent cases. Thus, direct flow (impingement jet) removal from the aneurysm dome, as indicated by angiograms in the proximally-covered case, was sufficient to cause full aneurysm healing in four weeks; however, aneurysm healing was not complete for the distally-covered case. These results support further investigations into the treatment of aneurysms by flow-modification using partial aneurysm-orifice coverage.

  20. Evaluation of indicator dilution process in X-ray angiographic images deteriorated by factors of technical origin

    International Nuclear Information System (INIS)

    Dernalowicz, J.; Goszczynska, H.; Mazur, P.

    1996-01-01

    Different sources of error in X-rays angiographic images have been discussed. Some kind of error which considerably influences densitometric analysis of time sequences of images - the fluctuation of image intensity during coronarography screening - has been emphasized and discussed in details. Three practical solutions of how to correct (compensate) such error have been proposed and described. (author)

  1. Unsatisfactory hepatic perfusion after placement of the infusaid pump: Angiographic correlation

    International Nuclear Information System (INIS)

    Andrews, J.C.; Williams, D.M.; Cho, K.J.; Knol, J.A.; Wahl, R.L.; Ensminger, W.D.

    1988-01-01

    Complete perfusion limited to the liver is essential to the success of regional chemotherapy for hepatic malignancy. Thirty-three patients with unsatisfactory hepatic artery perfusion scintigrams after surgical placement of a pump and catheter system were evaluated with selective angiography (31 cases) or digital subtraction angiography (DSA) via the pump side port (six cases). The cause of the perfusion defect was hepatic artery thrombosis (14 cases), extrahepatic flow through collaterals (13 cases), misplaced catheter (three cases), short proper hepatic artery without adequate length for mixing (two cases), and undefined (one case). DSA findings were diagnostic in only two cases. Angiographic findings directed attempted correction in 22 of 33 cases

  2. Fluoroscopically-guided transnasal insertion of ileus tube intestinal decompression in patients with inoperable malignant bowel obstruction

    International Nuclear Information System (INIS)

    Fang Shiming; Li Haili; Lin Qing; Mao Aiwu; Wu Shaoqiu; Jiang Haosheng; Cao Yan; Wang Zhenlei

    2011-01-01

    Objective: To assess the technical feasibility and effectiveness of fluoroscopically-guided transnasal insertion of ileus tube for intestinal decompression in the treatment of inoperable malignant bowel obstruction. Methods: A total of 211 patients with inoperable malignant bowel obstruction were enrolled in this study. The median KPS scale was 40 (ranged from 20 to 60). Under fluoroscopic guidance, transnasal insertion of ileus tube by using conventional technique or guidewire-catheter exchange technique was performed in all patients. The technical success rate, the clinical effective rate, the curative rate and adverse reactions as well as complications were documented. The correlation among the obstructive sites, obstruction causes and therapeutic effectiveness was analyzed. The ileus tube used in this study was a four-cavity and double-balloon catheter with a diameter of 16 F/18 f, which is produced by Cliny Company. Results: Transnasal drainage tube was successfully inserted into the proximal jejunum in all 211 patients with malignant bowel obstruction, and the total technical success rate was 100%. The initial technical success rate of the traditional technique and the catheter-guidewire exchange method was 85.5% (65/76) and 100% (135/135) respectively, the difference between the two was significant (P<0.05). After 24 hours, the clinical remission rate in the patients with high-level intestinal obstruction, lower-level intestinal obstruction and colorectal obstruction was 95.8% (46/48), 92.9% (117/126) and 83.8% (31/37), respectively. A follow-up of 4-245 days (mean 138 days) was conducted, and the total clinical cure rate was 27.5% (58/211). The clinical cure rate in small intestine obstruction and colorectal obstruction caused by primary tumor or recurrence was 12.7% (20/157) and 59.5% (22/37), respectively (P<0.05). The adverse reactions and complications included uncomfortable pharynx feeling or pain (99.1%, 199/221), the tube obstruction (23.2%, 49

  3. Clinical Investigation of Radiation Retinopathy Fundus and Fluorescein Angiographic Features

    Institute of Scientific and Technical Information of China (English)

    LiMei; QiuGT

    1999-01-01

    Purpose:To investigate the fundus and fluorescein angiographic features in the patients with radiation retinopathy.Clinical Materials:Color fundus photography and/or fluorescein angiography from 13 patients with nasopharyngeal carcinomas received external beam radiation were retrospectively analyzed.Reslts:In this study,26 damaged eyes of 13 patients eveloped some degree of radiation retinopathy.The earliest and most common finding was macular microvascular changes (microaneurysms and/or telangiectasia),which was observed in 100%(26/26)of the eyes.Intraretinal hemorrhages,macular capillary nonperfusion,and macular edema were noted in 84%,50%,and 42% of the eyes,respectively.Conclusions:Radiation retinopathy is common after external beam radiation of nasopharyngeal carcinomas.The prominent changes include maular microvascular changes,intraretinal hemorrhages and macular capillary nonperfusion.

  4. The angiographic findings of coronary arterial spasm (a report of 37 cases)

    International Nuclear Information System (INIS)

    Kuang Jianyi; Chen Jianhun; Du Zhimin; Li Xiangmin; Hu Chengheng

    2002-01-01

    Objective: The arterial spasm which often seen in the coronary angiography was considered as a result of the pathological spasm of the coronary artery or a complication of catheterization. The coronary arterial spasm is a considerable situation because it increases the danger of stenotic lesions in coronary artery, which should be managed immediately. Methods: In total 37 patients presented with coronary arterial spasm in the coronary angiography (Judkins method): 23 male and 14 female, aged 43-60 years (the 47 years in average). Spasms were relieved in all patients after the administration of glonoin. Results: Solitary spasm were the most common, the angiographic findings were long section (>10 mm) with stenosis of 50%-65% in left anterior descending artery (12 cases), or in the middle and near portion of the right coronary artery (5 cases), where the orifice of the branches were involved; severe stenosis of the orifice of the right coronary artery (3 cases); irregular, mild and local spasm in left anterior descending artery or circumflex (8 cases). And multiple spasm was observed in left anterior descending artery (4 cases) or in the right coronary artery (5 cases). In 19 cases, stenosis accompanying with spasm were revealed and local spasm were observed at the site of arterial sclerosis. Conclusion: The spasm owing to the catheterization doesn't result in chest discomfort and changes in EKG, while pathological spasm occurs in the population with high risk of coronary heart disease, which indicates the potential myocardial infraction. The angiographic findings helps differentiating the two situation

  5. C-reactive protein and angiographic characteristics of stable and unstable coronary artery disease : Data from the prospective PREVEND cohort

    NARCIS (Netherlands)

    Geluk, C.A.; Post, W.J.; Hillege, H.L.; Tio, R.A.; Tijssen, J.G.; van Dijk, R.B.; Dijk, Willem; Bakker, S.J.; de Jong, P.E.; van Gilst, W.H.; Zijlstra, F.

    Aims: High sensitive-C-reactive protein (hs-CRP) is associated with coronary risk, which may be explained by an association with (unstable) coronary artery disease (CAD). Until now, histopathological and angiographic studies have failed to consistently demonstrate a strong relationship. However,

  6. GDC 360 for the endovascular treatment of intracranial aneurysms: a matched-pair study analysing angiographic outcomes with GDC 3D coils in 38 patients

    International Nuclear Information System (INIS)

    Taschner, Christian A.; Thines, Laurent; Lejeune, Jean-Paul; El-Mahdy, Mohamed; Rachdi, Henda; Gauvrit, Jean-Yves; Pruvo, Jean-Pierre; Leclerc, Xavier

    2009-01-01

    The purpose of this study was to determine whether coil embolisation with a new complex-shaped Guglielmi Detachable Coil (GDC 360 ; Boston Scientific Neurovascular, Fremont, CA, USA) has any effect on the stability of aneurysm occlusion. Fifty-one consecutive patients with intracranial aneurysms treated with GDC 360 were included. Angiographic results and adverse neurological events during the follow-up period were recorded. For 38 patients treated with GDC 360 with available follow-up data, a corresponding patient treated with GDC 3D was identified from our database. Matches were sought for rupture status, location, aneurysmal size, and neck size. The angiographic outcome of these matched controls at 6 months was compared to aneurysms treated with GDC 360 . Initial angiographic controls for 38 patients treated with GDC 360 showed complete occlusion in 32 aneurysms, and a neck remnant in six. At 6-month follow-up, complete occlusion was found in 29, a neck remnant in eight, and a residual aneurysm in one. One patient treated with GDC 360 needed retreatment for a major recanalisation. In 38 matched patients treated with GDC 3D, initial angiographic controls found complete aneurysmal occlusion in 30 aneurysms and a residual neck in 8. At 6-month follow-up, 24 aneurysms were completely occluded, ten showed a neck remnant, and residual aneurysms were seen in four. Four patients, treated with GDC 3D, were retreated for major aneurysm recanalisations. Our data suggests that endovascular coil embolisation with GDC 360 might improve long-term stability of coiled aneurysms when compared to GDC 3D. (orig.)

  7. Angiographic Validation of the American College of Cardiology Foundation–The Society of Thoracic Surgeons Collaboration on the Comparative Effectiveness of Revascularization Strategies Study

    Science.gov (United States)

    Chakrabarti, Anjan K.; Grau-Sepulveda, Maria V.; O’Brien, Sean; Abueg, Cassandra; Ponirakis, Angelo; Delong, Elizabeth; Peterson, Eric; Klein, Lloyd W.; Garratt, Kirk N.; Weintraub, William S.; Gibson, C. Michael

    2017-01-01

    Background The goal of this study was to compare angiographic interpretation of coronary arteriograms by sites in community practice versus those made by a centralized angiographic core laboratory. Methods and Results The study population consisted of 2013 American College of Cardiology–National Cardiovascular Data Registry (ACC–NCDR) records with 2- and 3- vessel coronary disease from 54 sites in 2004 to 2007. The primary analysis compared Registry (NCDR)-defined 2- and 3-vessel disease versus those from an angiographic core laboratory analysis. Vessel-level kappa coefficients suggested moderate agreement between NCDR and core laboratory analysis, ranging from kappa=0.39 (95% confidence intervals, 0.32–0.45) for the left anterior descending artery to kappa=0.59 (95% confidence intervals, 0.55–0.64) for the right coronary artery. Overall, 6.3% (n=127 out of 2013) of those patients identified with multivessel disease at NCDR sites had had 0- or 1-vessel disease by core laboratory reading. There was no directional bias with regard to overcall, that is, 12.3% of cases read as 3-vessel disease by the sites were read as <3-vessel disease by the core laboratory, and 13.9% of core laboratory 3-vessel cases were read as <3-vessel by the sites. For a subset of patients with left main coronary disease, registry overcall was not linked to increased rates of mortality or myocardial infarction. Conclusions There was only modest agreement between angiographic readings in clinical practice and those from an independent core laboratory. Further study will be needed because the implications for patient management are uncertain. PMID:24496239

  8. Effects of sinomenine on the expression of microRNA-155 in 2,4,6-trinitrobenzenesulfonic acid-induced colitis in mice.

    Directory of Open Access Journals (Sweden)

    Qiao Yu

    Full Text Available Sinomenine, a pure alkaloid isolated in Chinese medicine from the root of Sinomenium acutum, has been demonstrated to have anti-inflammatory and immunosuppressive effects. MicroRNAs (miRNAs are gradually being recognized as critical mediators of disease pathogenesis via coordinated regulation of molecular effector pathways.After colitis was induced in mice by instillation of 5% (w/v 2,4,6-trinitrobenzenesulfonic acid (TNBS, sinomenine at a dose of 100 or 200 mg/kg was orally administered once daily for 7 days. We evaluated body weight, survival rate, diarrhea score, histological score and myeloperoxidase (MPO activity. The mRNA and protein expression levels of miR-155, c-Maf, TNF-α and IFN-γ were determined by quantitative RT-PCR and immunohistochemistry, respectively. Sinomenine (100 or 200 mg/kg-treated mice with TNBS-induced colitis were significantly improved in terms of body weight, survival rate, diarrhea score, histological score and MPO activity compared with untreated mice. Both dosages of sinomenine significantly decreased the mRNA and protein expression levels of c-Maf, TNF-α and IFN-γ, which elevated in TNBS-induced colitis. Furthermore, sinomenine at a dose of 200 mg/kg significantly decreased the level of miR-155 expression by 71% (p = 0.025 compared with untreated TNBS-induced colitis in mice.Our study evaluated the effects and potential mechanisms of sinomenine in the anti-inflammatory response via miRNA-155 in mice with TNBS-induced colitis. Our findings suggest that sinomenine has anti-inflammatory effects on TNBS-induced colitis by down-regulating the levels of miR-155 and several related inflammatory cytokines.

  9. Clinical and angiographic evaluation of the topic application of nitrate compounds in obstructive distal arteriopathies of the legs

    International Nuclear Information System (INIS)

    Perini, L.; Cavallo, A.; Perin, B.; Natale, F.; Borelli, G.; Bisiato, R.

    1988-01-01

    The vasodilatator effect obtained by the topic use of a nytroglycerin compound (TNG) has been angiographically tested on 11 patients affected by distal arteriopathy of the legs. All patients presented arteriosclerotic vascular lesions; two of them also suffered from diabetic angiopathy. Arteriography of the legs has proved to be a very important tool in the evaluation of the patients'response to the administration of the drug. An hour after 80 mg of TNG had been applied to the skin of the examined leg, arteriography showed a marked dilatation, especially of the muscular arteries and the undamaged tracts of the arteries of the legs. Angiographic evaluation of the functional blood supply thus obtained provides prognostic information and helps in the choice of the subsequent therapy. Furthermore, the clinical efficacy of prolonged treatment with this drug has been tested in 10 out of the 11 patients. They all responded with an immediate and persistent hemodynamic improvement, evaluated according to Fontaine's classification

  10. Five-year clinical and functional multislice computed tomography angiographic results after coronary implantation of the fully resorbable polymeric everolimus-eluting scaffold in patients with de novo coronary artery disease

    DEFF Research Database (Denmark)

    Onuma, Yoshinobu; Dudek, Dariusz; Thuesen, Leif

    2013-01-01

    This study sought to demonstrate the 5-year clinical and functional multislice computed tomography angiographic results after implantation of the fully resorbable everolimus-eluting scaffold (Absorb BVS, Abbott Vascular, Santa Clara, California).......This study sought to demonstrate the 5-year clinical and functional multislice computed tomography angiographic results after implantation of the fully resorbable everolimus-eluting scaffold (Absorb BVS, Abbott Vascular, Santa Clara, California)....

  11. The subtype of VSD and the angiographic differentiation

    International Nuclear Information System (INIS)

    Choe, Kyu Ok; Sul, Jun Hee; Lee, Sung Kyu; Cho, Bum Koo; Hong, Sung Nok

    1985-01-01

    VSD is the most common congenital cardiac malformation and the natural history depends not only on the age of patients and the size of defect but the subtype of VSD as well, important factor in clinical management of those patients. In 110 patients, with surgically repaired VSD in Yonsei Medical Center in 1984, the subtype of VSDs evaluated by surgical observation were correlated with LV angiogram findings to verify the incidence of subtype in Korean and the diagnostic accuracy to predict the subtype by angiogram. 1. 110 patients included 64 boys and 46 girls, the age ranged from 3 months to 14 years (average 4.6 years old). 2. Angiographic findings were interpreted as follows; a. Perimembranous defects were profiled in LAO 60 .deg. LV angiogram and located below the aortic valve. In inlet excavation the shunted blood opacified the recess between septal leaflet of tricuspid valve and interventricular septum in early phase, in infundibular excavation opacified the recess between anterior leaflet of TV and anterior free wall of RV and in trabecular excavation the shunted blood traversed anterior portion of TV ring, opacified trabecular portion of RV cavity. b. Subarterial types were profiled in RAO 30 .deg. LV angiogram, just below aortic valve as well as pulmonic valve. Total infundibular defects were profiled in RAO 30 .deg. and LAO 60 .deg. LV angiogram subaortic in location in both views. c. In muscular VSD the profiled angle was varied according to the subtype but the defects were separated from the aortic valve as muscular septum interposed between the aortic valve and the defect. 3. The incidence of subtype of VSDs evaluated by surgical observation were as follows. Subarterial type : 32 cases (29.1%) Total infundibular defect : 5 cases (4.5%) Perimembranous type : 73 cases (66.3%) Infundibular excavation : 32 cases (29.2%) Trabecular excavation : 28 cases (25.5%) Inlet excavation : 10 cases (9.1%) Mixed : 3 cases (2.7%) Muscular type : 1 cases (0.9%) Total 63

  12. Metallic Limus-Eluting Stents Abluminally Coated with Biodegradable Polymers: Angiographic and Clinical Comparison of a Novel Ultra-Thin Sirolimus Stent Versus Biolimus Stent in the DESTINY Randomized Trial.

    Science.gov (United States)

    Lemos, Pedro A; Abizaid, Alexandre A C; Meireles, George C; Sarmento-Leite, Rogério; Prudente, Mauricio; Cantarelli, Marcelo; Dourado, Adriano D; Mariani, Jose; Perin, Marco A; Costantini, Costantino; Costa, Ricardo A; Costa, José Ribamar; Chamie, Daniel; Campos, Carlos A; Ribeiro, Expedito

    2015-12-01

    To evaluate the outcomes of patients treated with a new drug-eluting stent formulation with low doses of sirolimus, built in an ultra-thin-strut platform coated with biodegradable abluminal coating. This study is a randomized trial that tested the main hypothesis that the angiographic late lumen loss of the novel sirolimus-eluting stent is noninferior compared with commercially available biolimus-eluting stent. A final study population comprising 170 patients with one or two de novo lesions was randomized in the ratio 2:1 for sirolimus-eluting stent or biolimus-eluting stent, respectively. The primary endpoint was 9-month angiographic in-stent late lumen loss. Adverse clinical events were prospectively collected for 1 year. After 9 months, the novel sirolimus-eluting stent was shown noninferior compared with the biolimus stent for the primary endpoint (angiographic in-stent late lumen loss: 0.20 ± 0.29 mm vs. 0.15 ± 0.20 mm, respectively; P value for noninferiority <0.001). The 1-year incidence of death, myocardial infarction, repeat revascularization, and stent thrombosis remained low and not significantly different between the groups. The present randomized trial demonstrates that the tested novel sirolimus-eluting stent was angiographically noninferior in comparison with a last-generation biolimus-eluting stent. © 2015 John Wiley & Sons Ltd.

  13. Methods for improvement of some parameters of medical X-ray diagnostic equipment. Basic faults in selection of appropriate new or used units

    International Nuclear Information System (INIS)

    Tonev, M.; Danev, N.; Constantinov, B.

    2004-01-01

    An analysis is made of the factors determining the quality and performance of the main types of medical equipment: conventional radiographic and fluoroscopic X-ray unit; X-ray computer tomograph (CT); angiographic, mammographic, densitometric and dental X-ray equipment; magnetic resonance MRI. The aim is to give certain directions for the method one should adopt on choosing and purchasing X-ray equipment. Also one should take into consideration the new Health law and the Regulation for radiation protection of persons undergoing medical examination or treatment. The problems can be solved with the close cooperation between radiologists, medical physicists and x-ray engineers

  14. Radiologic placement of Hickman catheters

    International Nuclear Information System (INIS)

    Robertson, L.J.; Mauro, M.A.; Jaques, P.F.

    1988-01-01

    Hickman catheter inserter has previously been predominantly accomplished surgically by means of venous cutdown or percutaneous placement in the operating room. The authors describe their method and results for 55 consecutive percutaneous placements of Hickman catheters in the interventional radiology suite. Complication rates were comparable to those for surgical techniques. Radiologic placement resulted in increased convenience, decreased time and cost of insertion, and super fluoroscopic control of catheter placement and any special manipulations. Modern angiographic materials provide safer access to the subclavian vein than traditional methods. The authors conclude that radiologic placement of Hickman catheters offers significant advantages over traditional surgical placement

  15. Operation logic and functionality of automatic dose rate and image quality control of conventional fluoroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Pei-Jan Paul [Department of Radiology, Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, Massachusetts 02115 (United States)

    2009-05-15

    New generation of fluoroscopic imaging systems is equipped with spectral shaping filters complemented with sophisticated automatic dose rate and image quality control logic called ''fluoroscopy curve'' or ''trajectory''. Such fluoroscopy curves were implemented first on cardiovascular angiographic imaging systems and are now available on conventional fluoroscopy equipment. This study aims to investigate the control logic operations under the fluoroscopy mode and acquisition mode (equivalent to the legacy spot filming) of a conventional fluoroscopy system typically installed for upper-lower gastrointestinal examinations, interventional endoscopy laboratories, gastrointestinal laboratory, and pain clinics.

  16. Bronchial and non-bronchial systemic arteries: value of multidetector CT angiography in diagnosis and angiographic embolisation feasibility analysis

    International Nuclear Information System (INIS)

    Lin, Yuning; Chen, Ziqian; Yang, Xizhang; Zhong, Qun; Zhang, Hongwen; Yang, Li; Xu, Shangwen; Li, Hui

    2013-01-01

    The aim of this study is to evaluate the diagnostic performance of multidetector CT angiography (CTA) in depicting bronchial and non-bronchial systemic arteries in patients with haemoptysis and to assess whether this modality helps determine the feasibility of angiographic embolisation. Fifty-two patients with haemoptysis between January 2010 and July 2011 underwent both preoperative multidetector CTA and digital subtraction angiography (DSA) imaging. Diagnostic performance of CTA in depicting arteries causing haemoptysis was assessed on a per-patient and a per-artery basis. The feasibility of the endovascular treatment evaluated by CTA was analysed. Sensitivity, specificity, and positive and negative predictive values for those analyses were determined. Fifty patients were included in the artery-presence-number analysis. In the per-patient analysis, neither CTA (P=0.25) nor DSA (P=1.00) showed statistical difference in the detection of arteries causing haemoptysis. The sensitivity, specificity, and positive and negative predictive values were 94%, 100%, 100%, and 40%, respectively, for the presence of pathologic arteries evaluated by CTA, and 98%, 100%, 100%, and 67%, respectively, for DSA. On the per-artery basis, CTA correctly identified 97% (107/110). Fifty-two patients were included in the feasibility analysis. The performance of CTA in predicting the feasibility of angiographic embolisation was not statistically different from the treatment performed (P=1.00). The sensitivity, specificity, and positive and negative predictive values were 96%, 80%, 98% and 67%, respectively, for CTA. Multidetector CTA is an accurate imaging method in depicting the presence and number of arteries causing haemoptysis. This modality is also useful for determining the feasibility of angiographic embolisation for haemoptysis.

  17. Chest pain in patients with arterial hypertension, angiographically normal coronary arteries and stiff aorta: the aortic pain syndrome.

    Science.gov (United States)

    Stakos, Dimitrios A; Tziakas, Dimitrios N; Chalikias, George; Mitrousi, Konstantina; Tsigalou, Christina; Boudoulas, Harisios

    2013-01-01

    Arterial hypertension is often associated with a stiff aorta as a result of collagen accumulation in the aortic wall and may produce chest pain. In the present study, possible interrelationships between aortic function, collagen turnover and exercise-induced chest pain in patients with arterial hypertension and angiographically normal coronary arteries were investigated. Ninety-seven patients with arterial hypertension, angiographically normal coronary arteries and no evidence of myocardial ischemia on nuclear cardiac imaging during exercise test were studied. Of these, 43 developed chest pain during exercise (chest pain group) while 54 did not (no chest pain group). Carotid femoral pulse-wave velocity (PWVc-f) was used to assess the elastic properties of the aorta. Amino-terminal pro-peptides of pro-collagen type I, (PINP, reflecting collagen synthesis), serum telopeptides of collagen type I (CITP, reflecting collagen degradation), pro-metalloproteinase 1 (ProMMP-1), and tissue inhibitor of metalloproteinase 1 (TIMP-1, related to collagen turnover) were measured in plasma by immunoassay. The chest pain group had higher PWVc-f, higher and /CITP ratio, and lower proMMP-1/ TIMP-1 ratio compared to the no chest pain group. PWVc-f (t=2.53, p=0.02) and PINP (t=2.42, p=0.02) were independently associated with the presence of chest pain in multiple regression analysis. Patients with arterial hypertension, exercise-induced chest pain and angiographically normal coronary arteries, without evidence of exercise-induced myocardial ischemia, had a stiffer aorta compared to those without chest pain. Alterations in collagen type I turnover that favor collagen accumulation in the aortic wall may contribute to aortic stiffening and chest pain in these patients.

  18. A digital fluoroscopic imaging system for verification during external beam radiotherapy

    International Nuclear Information System (INIS)

    Takai, Michikatsu

    1990-01-01

    A digital fluoroscopic (DF) imaging system has been constructed to obtain portal images for verification during external beam radiotherapy. The imaging device consists of a fluorescent screen viewed by a highly sensitive video camera through a mirror. The video signal is digitized and processed by an image processor which is linked on-line with a host microcomputer. The image quality of the DF system was compared with that of film for portal images of the Burger phantom and the Alderson anthropomorphic phantom using 10 MV X-rays. Contrast resolution of the DF image integrated for 8.5 sec. was superior to the film resolution, while spatial resolution was slightly inferior. The DF image of the Alderson phantom processed by the adaptive histogram equalization was better in showing anatomical landmarks than the film portal image. The DF image integrated for 1 sec. which is used for movie mode can show patient movement during treatment. (author)

  19. Radiation injury of the skin following diagnostic and interventional fluoroscopic procedures

    International Nuclear Information System (INIS)

    Koenig, T.R.; Wagner, L.K.; Mettler, F.A.

    2001-01-01

    Many radiation injuries to the skin, resulting from diagnostic and interventional fluoroscopic procedures, have been reported in recent years. In some cases skin damage was severe and debilitating. We analyzed 72 reports of skin injuries for progression and location of injury, type and number of procedures, and contributing patient and operator factors. Most cases (46) were related to coronary angiography and percutaneous transluminal coronary angioplasty (PTCA). A smaller number was documented after cardiac radiofrequency catheter ablation (12), transjugular intrahepatic portosystemic shunt (TIPS) placement (7), neuroradiological interventions (3) and other procedures (4). Important factors leading to skin injuries were long exposure times over the same skin area, use of high dose rates, irradiation through thick tissue masses, hypersensitivity to radiation, and positioning of arms or breasts into the radiation entrance beam. Physicians were frequently unaware of the high radiation doses involved and did not recognize the injuries as radiation induced. Based on these findings, recommendations to reduce dose and improve patient care are provided. (author)

  20. Fluoroscopic removal of metallic foreign bodies in the stomach with a magnetic orogastric tube

    International Nuclear Information System (INIS)

    Paulson, E.K.; Jaffe, R.B.

    1989-01-01

    Thirty-six cases of metallic foreign bodies in the stomach were referred for fluoroscopically guided removal by means of a 5-mm diameter magnet coupled to an orogastric tube. The foreign bodies included 29 disk batteries, two nails, two screws, a nut and bolt, an unopened jack knife, and a metallic whistle. The average patient age was 4 years (range, 11 months to 13 years). Removal was successful in 33 of the 36 cases (92%). The three failures were the result of inadvertent passage of the foreign body into the duodenum (two cases) and lack of magnetic attraction (one case). There were no complications. No patient required general anesthesia, hospital admission, or endoscopic surgical intervention

  1. Clinical comparison between 100 mm photofluorography and digital (1024/sup 2/) fluoroscopic image acquisition

    International Nuclear Information System (INIS)

    Hynes, D.M.; Edmonds, E.W.; Rowlands, J.A.; Porter, A.J.; Toth, B.D.

    1986-01-01

    The authors describe current work in progress in which a clinical image can be recorded on both 100-mm film and a 1,024/sup 2/ image store with the same exposure. The 100-mm film is exposed in the usual manner. However, the same radiation exposure is utilized by the optics of the beam splitter to transfer the output image of the intensifier into a 1,024/sup 2/ image store and thence to hard copy by multiformat camera or laser printer. Comparative phantom and clinical images will be presented, along with observations on dose rates needed for diagnostic digital imaging. Use of this system may allow fluoroscopic dose rates to be reduced

  2. Angiographic embolization in the treatment of intrahepatic arterial bleeding in patients with blunt abdominal trauma.

    Science.gov (United States)

    Kong, Ya-Lin; Zhang, Hong-Yi; He, Xiao-Jun; Zhao, Gang; Liu, Cheng-Li; Xiao, Mei; Zhen, Yu-Ying

    2014-04-01

    Angiographic embolization (AE) as an adjunct non-operative treatment of intrahepatic arterial bleeding has been widely used. The present study aimed to evaluate the efficacy of selective AE in patients with hepatic trauma. Seventy patients with intrahepatic arterial bleeding after blunt abdominal trauma who had undergone selective AE in 10 years at this institution were retrospectively reviewed. The criteria for selective AE included active extravasation on contrast-enhanced CT, an episode of hypotension or a decrease in hemoglobin level during the non-operative treatment. The data of the patients included demographics, grade of liver injuries, mechanism of blunt abdominal trauma, associated intra-abdominal injuries, indications for AE, angiographic findings, type of AE, and AE-related hepatobiliary complications. In the 70 patients, 32 (45.71%) had high-grade liver injuries. Extravazation during the early arterial phase mainly involved the right hepatic segments. Thirteen (18.57%) patients underwent embolization of intrahepatic branches and the extrahepatic trunk and these patients all developed AE-related hepatobiliary complications. In 19 patients with AE-related complications, 14 received minimally invasive treatment and recovered without severe sequelae. AE is an adjunct treatment for liver injuries. Selective and/or super-selective AE should be advocated to decrease the incidence and severity of AE-related hepatobiliary complications.

  3. An angiographic study of left- and right-ventricular function in patients with alcoholic heart and dilatation cardiomyopathy

    International Nuclear Information System (INIS)

    Savchenko, A.P.; Samko, A.N.; Smetnev, A.S.; Grudtsyn, G.V.

    1986-01-01

    An angiographic study of left- and right-ventricular function in 57 patients with alcoholic heart and dilatation cardiomyopathy demonstrated preclinical disorders of left-ventricular myocardial contractility and more marked right-ventricular changes in patients with second-stage chronic alcoholism. In cases of dilatation cardiomyopathy, left-ventricular dysfunction was predominant, while right-venricular changes were less pronouced

  4. Angiographic evaluation of response to preoperative chemotherapy in osteosarcoma

    International Nuclear Information System (INIS)

    Carrasco, C.H.; Charnsangavej, C.; Richii, W.; Wallace, S.; Chawla, S.P.; Raymond, A.K.; Murray, J.A.; Benjamin, R.S.

    1986-01-01

    Preoperative chemotherapy for osteosarcoma facilitates local resection for limb salvage and serves as an in vivo chemosensitivity assay. Arteriograms obtained with each intraarterial course of cisplatin in 79 patients with osteosarcoma were evaluated. Complete remission was defined as complete or nearly complete disappearance of tumor vascularity after treatment. A minimal decrease, no change, or an increase in tumor vascularity was not considered a response. If a complete remission is assumed to represent ≥ 90% histologic tumor necrosis which correlates with prolonged disease-free survival, the sensitivity of an angiographic complete remission was 95%, the specificity was 58%, the predictive value of a negative study was 90%, and the predictive value of a positive study was 75%. Angiography is the best clinical technique for evaluating the therapeutic response in osteosarcoma. Results correlate well with the degree of tumor necrosis, particularly in respect to significant residual viable tumor

  5. Computer tomographic and angiographic studies of histologically confirmed intrahepatic masses

    International Nuclear Information System (INIS)

    Janson, R.; Lackner, K.; Paquet, K.J.; Thelen, M.; Thurn, P.

    1980-01-01

    The computer tomographic and angiographic findings in 53 patients with intrahepatic masses were compared. The histological findings show that 17 were due to echinococcus, 12 were due to hepatic carcinoma, ten were metastases, five patients had focal nodular hyperplasia, three an alveolar echinococcus and there were three cases with an haemangioma of the liver and a further three liver abscesses. Computer tomography proved superior in peripherally situated lesions, and in those in the left lobe of the liver. Arteriography was better at demonstrating lesions below 2 cm in size, particularly vascular tumours. As a pre-operative measure, angiography is to be preferred since it is able to demonstrate anatomic anomalies and variations in the blood supply, as well as invasion of the portal vein or of the inferior vena cava. (orig.) [de

  6. Computer tomographic and angiographic studies of histologically confirmed intrahepatic masses

    Energy Technology Data Exchange (ETDEWEB)

    Janson, R.; Lackner, K.; Paquet, K.J.; Thelen, M.; Thurn, P.

    1980-06-01

    The computer tomographic and angiographic findings in 53 patients with intrahepatic masses were compared. The histological findings show that 17 were due to echinococcus, 12 were due to hepatic carcinoma, ten were metastases, five patients had focal nodular hyperplasia, three an alveolar echinococcus and there were three cases with an haemangioma of the liver and a further three liver abscesses. Computer tomography proved superior in peripherally situated lesions, and in those in the left lobe of the liver. Arteriography was better at demonstrating lesions below 2 cm in size, particularly vascular tumours. As a pre-operative measure, angiography is to be preferred since it is able to demonstrate anatomic anomalies and variations in the blood supply, as well as invasion of the portal vein or of the inferior vena cava.

  7. Angiographic patterns of carotid-cavernous fistulas

    International Nuclear Information System (INIS)

    Georgieva, G.; Jekova, M.; Genov, P.; Hadjidekov, V.

    2006-01-01

    Full text: The aim of the study is to present our experience in angiographic evaluation of carotid-cavernous fistulas. 8 patients with carotid-cavernous fistula (6 men and 2 women, range of age from 15 to 62) are included in the study out of all undergone cerebral angiography for a four year period (1996 - 2000). All patients underwent CT brain examination, two out of 8 - MRI. Visualization of ipsi- and contra lateral cavernous sinus and ophthalmic vein dilatation are assessed. In all cases the communication between the internal carotid artery and the cavernous sinus has been assessed as direct. Near simultaneous visualization of the home internal carotid artery, the dilated ipsilateral cavernous sinus and dilated superior ophthalmic vein is found in 2 patients, simultaneous visualization of both cavernous sinuses - in two. In 1 patient the early visualization of the cavernous sinus through the fistula enabled visualization of ipsilateral main internal carotid artery from the contra lateral circulation through the communicating arteries.In 1 excessive contralateral cavernous sinus and contralateral superior ophthalmic vein dilatation is detected. In other 1 excessive flow to dilated ipsilateral cavernous sinus lead insufficient circulation in distal vessels. Digital subtraction Angiography remains the most suitable imaging method in carotid-cavernous fistula assessment regarding type of communication and level of following vessels morphology changes

  8. Characterization of MOSFET Dosimeter Angular Response Using a Spherical Phantom for Fluoroscopic Dosimetry.

    Science.gov (United States)

    Wang, Chu; Hill, Kevin; Yoshizumi, Terry

    2016-01-01

    Metal-Oxide Semiconductor Field-Effect Transistor (MOSFET) dosimeters, placed in anthropomorphic phantoms, are a standard method for organ dosimetry in medical x-ray imaging applications. However, many x-ray applications, particularly fluoroscopy procedures, use variable projection angles. During dosimetry, the MOSFET detector active area may not always be perpendicular to the x-ray beam. The goal of this study was to characterize the dosimeter's angular response in the fluoroscopic irradiation involved in pediatric cardiac catheterization procedures, during which a considerable amount of fluoroscopic x-ray irradiation is often applied from various projection angles. A biological x-ray irradiator was used to simulate the beam quality of a biplane fluoroscopy imaging system. A custom-designed acrylic spherical scatter phantom was fabricated to measure dosimeter response (in mV) in two rotational axes, axial (ψ) and normal-to-axial (θ), in 30° increments, as well as four common oblique angles used in cardiac catheterization: a) 90° Left Anterior Oblique (LAO); b) 70° LAO/ 20° Cranial; c) 20° LAO/ 15° Cranial; and d) 30° Right Anterior Oblique (RAO). All results were normalized to the angle where the dosimeter epoxy is perpendicular to the beam or the Posterior-Anterior projection angle in the clinical setup. The relative response in the axial rotation was isotropic (within ± 10% deviation); that in the normal-to-axial rotation was isotropic in all angles except the ψ = 270° angle, where the relative response was 83 ± 9%. No significant deviation in detector response was observed in the four common oblique angles, with their relative responses being: a) 102 ± 3%; b) 90 ± 3%; c) 92 ± 3%; and d) 95 ± 3%, respectively. These angular correction factors will be used in future dosimetry studies for fluoroscopy. The spherical phantom may be useful for other applications, as it allows the measurement of dosimeter response in virtually all angles in the 3

  9. Pediatric renovascular hypertension in Thailand: CT angiographic findings

    Energy Technology Data Exchange (ETDEWEB)

    Visrutaratna, Pannee; Srisuwan, Tanop; Sirivanichai, Chusak [Chiang Mai University, Department of Radiology, Faculty of Medicine, Chiang Mai (Thailand)

    2009-12-15

    Renovascular disease is an uncommon but important cause of hypertension in children. When unrecognized and untreated, renovascular hypertension in children can have serious complications. To review the causes of renovascular hypertension and computed tomography angiographic (CTA) findings in children and adolescents. Twenty-eight CTAs from January 2004 to March 2008 of 23 children and adolescents with hypertension were reviewed for the causes and CTA findings. Nine of the 23 children (39%) had abnormal renal arteries with or without abnormal abdominal aortas. Four of these children had Takayasu arteritis, one had moyamoya disease, and one had median arcuate ligament syndrome. One with chronic pyelonephritis had severe stenosis of the proximal right renal artery. The other two children had renal artery stenosis with a nonspecific cause. One child with a normal abdominal aorta and renal arteries had a right suprarenal mass. On pathological examination a ganglioneuroma was found. CTA can help in diagnosis of renovascular hypertension in children and adolescents. Although CTA is not a screening modality, it is appropriate in some situations. (orig.)

  10. Pediatric renovascular hypertension in Thailand: CT angiographic findings

    International Nuclear Information System (INIS)

    Visrutaratna, Pannee; Srisuwan, Tanop; Sirivanichai, Chusak

    2009-01-01

    Renovascular disease is an uncommon but important cause of hypertension in children. When unrecognized and untreated, renovascular hypertension in children can have serious complications. To review the causes of renovascular hypertension and computed tomography angiographic (CTA) findings in children and adolescents. Twenty-eight CTAs from January 2004 to March 2008 of 23 children and adolescents with hypertension were reviewed for the causes and CTA findings. Nine of the 23 children (39%) had abnormal renal arteries with or without abnormal abdominal aortas. Four of these children had Takayasu arteritis, one had moyamoya disease, and one had median arcuate ligament syndrome. One with chronic pyelonephritis had severe stenosis of the proximal right renal artery. The other two children had renal artery stenosis with a nonspecific cause. One child with a normal abdominal aorta and renal arteries had a right suprarenal mass. On pathological examination a ganglioneuroma was found. CTA can help in diagnosis of renovascular hypertension in children and adolescents. Although CTA is not a screening modality, it is appropriate in some situations. (orig.)

  11. Cerebral Angiographic Findings of Cosmetic Facial Filler-related Ophthalmic and Retinal Artery Occlusion.

    Science.gov (United States)

    Kim, Yong-Kyu; Jung, Cheolkyu; Woo, Se Joon; Park, Kyu Hyung

    2015-12-01

    Cosmetic facial filler-related ophthalmic artery occlusion is rare but is a devastating complication, while the exact pathophysiology is still elusive. Cerebral angiography provides more detailed information on blood flow of ophthalmic artery as well as surrounding orbital area which cannot be covered by fundus fluorescein angiography. This study aimed to evaluate cerebral angiographic features of cosmetic facial filler-related ophthalmic artery occlusion patients. We retrospectively reviewed cerebral angiography of 7 patients (4 hyaluronic acid [HA] and 3 autologous fat-injected cases) showing ophthalmic artery and its branches occlusion after cosmetic facial filler injections, and underwent intra-arterial thrombolysis. On selective ophthalmic artery angiograms, all fat-injected patients showed a large filling defect on the proximal ophthalmic artery, whereas the HA-injected patients showed occlusion of the distal branches of the ophthalmic artery. Three HA-injected patients revealed diminished distal runoff of the internal maxillary and facial arteries, which clinically corresponded with skin necrosis. However, all fat-injected patients and one HA-injected patient who were immediately treated with subcutaneous hyaluronidase injection showed preserved distal runoff of the internal maxillary and facial arteries and mild skin problems. The size difference between injected materials seems to be associated with different angiographic findings. Autologous fat is more prone to obstruct proximal part of ophthalmic artery, whereas HA obstructs distal branches. In addition, hydrophilic and volume-expansion property of HA might exacerbate blood flow on injected area, which is also related to skin necrosis. Intra-arterial thrombolysis has a limited role in reconstituting blood flow or regaining vision in cosmetic facial filler-associated ophthalmic artery occlusions.

  12. Supplementation of bone marrow aspirate-derived platelet-rich plasma for treating radiation-induced ulcer after cardiac fluoroscopic procedures: A preliminary report

    Directory of Open Access Journals (Sweden)

    Soh Nishimoto

    2012-01-01

    Full Text Available Background: The frequency of encountering radiodermatitis caused by X-ray fluoroscopic procedures for ischaemic heart disease is increasing. In severe cases, devastating ulcers with pain, for which conservative therapy is ineffective, emerge. Radiation-induced ulcers are notorious for being difficult to treat. Simple skin grafting often fails because of the poor state of the wound bed. A vascularized flap is a very good option. However, the non-adherence of the well-vascularized flap with the irradiated wound bed is frequently experienced. Aim: To ameliorate the irradiated wound bed, bone marrow-derived platelet-rich plasma (bm-PRP was delivered during the surgery. Materials and Methods: Four patients with severe cutaneous radiation injury accompanied by unbearable pain after multiple fluoroscopic procedures for ischaemic heart disease were treated. Wide excision of the lesion and coverage with a skin flap supplemented with bm-PRP injection was performed. Results: All patients obtained wound closure and were relieved from pain. No complication concerning the bone marrow aspiration and delivery of bm-PRP was observed. Conclusions: Supplementation of bm-PRP can be an option without major complications, time, and cost to improve the surgical outcome for irradiated wounds.

  13. Bronchial and non-bronchial systemic arteries: value of multidetector CT angiography in diagnosis and angiographic embolisation feasibility analysis.

    Science.gov (United States)

    Lin, Yuning; Chen, Ziqian; Yang, Xizhang; Zhong, Qun; Zhang, Hongwen; Yang, Li; Xu, Shangwen; Li, Hui

    2013-12-01

    The aim of this study is to evaluate the diagnostic performance of multidetector CT angiography (CTA) in depicting bronchial and non-bronchial systemic arteries in patients with haemoptysis and to assess whether this modality helps determine the feasibility of angiographic embolisation. Fifty-two patients with haemoptysis between January 2010 and July 2011 underwent both preoperative multidetector CTA and digital subtraction angiography (DSA) imaging. Diagnostic performance of CTA in depicting arteries causing haemoptysis was assessed on a per-patient and a per-artery basis. The feasibility of the endovascular treatment evaluated by CTA was analysed. Sensitivity, specificity, and positive and negative predictive values for those analyses were determined. Fifty patients were included in the artery-presence-number analysis. In the per-patient analysis, neither CTA (P = 0.25) nor DSA (P = 1.00) showed statistical difference in the detection of arteries causing haemoptysis. The sensitivity, specificity, and positive and negative predictive values were 94%, 100%, 100%, and 40%, respectively, for the presence of pathologic arteries evaluated by CTA, and 98%, 100%, 100%, and 67%, respectively, for DSA. On the per-artery basis, CTA correctly identified 97% (107/110). Fifty-two patients were included in the feasibility analysis. The performance of CTA in predicting the feasibility of angiographic embolisation was not statistically different from the treatment performed (P = 1.00). The sensitivity, specificity, and positive and negative predictive values were 96%, 80%, 98% and 67%, respectively, for CTA. Multidetector CTA is an accurate imaging method in depicting the presence and number of arteries causing haemoptysis. This modality is also useful for determining the feasibility of angiographic embolisation for haemoptysis. © 2013 The Authors. Journal of Medical Imaging and Radiation Oncology © 2013 The Royal Australian and New Zealand College of Radiologists.

  14. Brachytherapy using holmium-166 liquid balloon system for in-stent restenosis: 6 months clinical and angiographic follow-up

    Energy Technology Data Exchange (ETDEWEB)

    Kim, M. H.; Kim, S. K.; Cha, K. S.; Kim, Y. D.; Lee, H. S.; Kang, D. Y. [Donga University College of Medicine, Busan (Korea, Republic of)

    2002-07-01

    In western country, 3 systems of brachytherapy using commercial radioactive source has been established. However, brachytherapy using holmium-166 liquid balloon system (HLBS) for the patient with stent restenosis has not been studied enough. 30 patients (male 23, mean age 58.9 7.7) were enrolled. Target dose was 15 Gy at 1 mm distance from the intimal surface. Clinical diagnoses of the study patients included stable angina 10 and unstable angina 20 patients. Target lesion included LAD 19, LCx 5 and RCA 6 arteries. Pre-brachytherapy treatment included cutting balloon angioplasty in 25, rotational atherectomy in 5 patients. Fractionation and stepping was done in 6 patients each. Follow-up angiography was done in 19 patients. Of them, 4 cases developed angiographic restenosis (21%) including 3 cases of total occlusion. 6 month MACE (major adverse cardiac event) occurred in 5 patients including one sudden cardiac death in a patient with 80 year-old, triple-vessel diseased patient. Vascular brachytherapy using HLBS is a safe and effective treatment modality for in-stent restenosis showing acceptable angiographic and clinical result.

  15. Dipyridamole-induced ST segment depression during thallium-201 imaging in patients with coronary artery disease: angiographic and hemodynamic determinants

    International Nuclear Information System (INIS)

    Chambers, C.E.; Brown, K.A.

    1988-01-01

    To examine the angiographic and hemodynamic determinants of dipyridamole-induced ST segment depression in patients with coronary artery disease, 41 patients with angiographically documented coronary disease who underwent dipyridamole-thallium-201 myocardial scintigraphy were studied. Dipyridamole-induced ST depression occurred in 14 (34%) of the 41 patients. Stepwise multivariate logistic regression was performed to compare the predictive value of angiographic findings (good coronary collateral vessels, jeopardized collateral vessels, multivessel disease), hemodynamic changes (changes in heart rate, systolic pressure, diastolic pressure and rate-pressure product), thallium-201 results (perfusion defect, thallium-201 redistribution) and demographic data (age, gender, medications). Only the presence of good coronary collateral vessels (p less than 0.02) and increases in rate-pressure product after dipyridamole infusion (p less than 0.02) were significant multivariate predictors of dipyridamole-induced ST depression. Good collateral vessels were more common in the group with ST depression (11 [79%] of 14) than they were in the group without ST depression (6 [22%] of 27; p less than 0.001). Rate-pressure product increased 2,835 +/- 1,648 beats/min.mm Hg in the group with ST depression compared with 1,179 +/- 1,417 beats/min.mm Hg in patients without ST depression (p less than 0.005). In conclusion, dipyridamole-induced ST segment depression in patients with coronary artery disease appears to be related to 1) the presence of good coronary collateral vessels, which may act by facilitating coronary steal, and 2) increases in rate-pressure product, reflecting increased myocardial oxygen demand. These observations may explain the lack of prognostic value of dipyridamole-induced ST segment depression described in previous reports

  16. Evaluation of the impact of a system for real-time visualisation of occupational radiation dose rate during fluoroscopically guided procedures

    International Nuclear Information System (INIS)

    Sandblom, V; Almén, A; Cederblad, A.; Båth, M; Lundh, C; Mai, T; Rystedt, H

    2013-01-01

    Optimisation of radiological protection for operators working with fluoroscopically guided procedures has to be performed during the procedure, under varying and difficult conditions. The aim of the present study was to evaluate the impact of a system for real-time visualisation of radiation dose rate on optimisation of occupational radiological protection in fluoroscopically guided procedures. Individual radiation dose measurements, using a system for real-time visualisation, were performed in a cardiology laboratory for three cardiologists and ten assisting nurses. Radiation doses collected when the radiation dose rates were not displayed to the staff were compared to radiation doses collected when the radiation dose rates were displayed. When the radiation dose rates were displayed to the staff, one cardiologist and the assisting nurses (as a group) significantly reduced their personal radiation doses. The median radiation dose (H p (10)) per procedure decreased from 68 to 28 μSv (p = 0.003) for this cardiologist and from 4.3 to 2.5 μSv (p = 0.001) for the assisting nurses. The results of the present study indicate that a system for real-time visualisation of radiation dose rate may have a positive impact on optimisation of occupational radiological protection. In particular, this may affect the behaviour of staff members practising inadequate personal radiological protection. (paper)

  17. Implementation of a competency check-off in diagnostic fluoroscopy for radiology trainees: impact on reducing radiation for three common fluoroscopic exams in children

    Energy Technology Data Exchange (ETDEWEB)

    Shah, Sweta [University of Missouri-Kansas City SOM, Department of Radiology, Kansas City, MO (United States); Desouches, Stephane L. [University of Missouri-Kansas City SOM, Department of Radiology, Kansas City, MO (United States); St. Luke' s Hospital, Department of Radiology, Kansas City, MO (United States); Lowe, Lisa H.; Kasraie, Nima; Reading, Brenton [University of Missouri-Kansas City SOM, Department of Radiology, Kansas City, MO (United States); Children' s Mercy Hospitals and Clinics, Department of Radiology, Kansas City, MO (United States)

    2014-07-24

    Fluoroscopy is an important tool for diagnosis in the pediatric population, but it carries the risk of radiation exposure. Because radiology resident education and experience in the use of fluoroscopy equipment in children vary, we implemented an intervention to standardize fluoroscopy training. The purpose of this study is to determine the impact of implementing a fluoroscopy competency check-off for radiology resident trainees aimed at decreasing radiation exposure in three common pediatric fluoroscopic studies. A fluoroscopy competency check-off form was developed for radiology resident trainees performing pediatric procedures. Techniques used to limit radiation exposure for common pediatric radiologic studies were reviewed as part of the check-off process. Pediatric radiologists supervised each trainee until they demonstrated competence to independently perform three specified procedures. Radiation dose was recorded for the three procedures, upper GI (UGI), voiding cystourethrogram (VCUG) and oropharyngeal (OPM) exams, over 6 months preceding and 6 months following implementation of the competency check-off. The mean cumulative dose for each procedure was compared before and after implementation of competency check-off using a Kruskal-Wallis test. During the 12-month study period doses from 909 fluoroscopic procedures were recorded. In the 6 months preceding competency check-off implementation, procedures were performed by 24 radiology resident trainees including 171 UGI, 176 VCUG and 171 OPM exams. In the 6 months following competency check-off, 23 trainees performed 114 UGI, 145 VCUG and 132 OPM exams. After competency check-off implementation, a statistically significant reduction in average radiation dose was found for all three studies (P < 0.001). Median cumulative doses (mGy) were decreased by 33%, 36% and 13% for UGIs, VCUGs and OPMs, respectively. Implementation of a competency check-off for radiology resident trainees can reduce average radiation

  18. Implementation of a competency check-off in diagnostic fluoroscopy for radiology trainees: impact on reducing radiation for three common fluoroscopic exams in children

    International Nuclear Information System (INIS)

    Shah, Sweta; Desouches, Stephane L.; Lowe, Lisa H.; Kasraie, Nima; Reading, Brenton

    2015-01-01

    Fluoroscopy is an important tool for diagnosis in the pediatric population, but it carries the risk of radiation exposure. Because radiology resident education and experience in the use of fluoroscopy equipment in children vary, we implemented an intervention to standardize fluoroscopy training. The purpose of this study is to determine the impact of implementing a fluoroscopy competency check-off for radiology resident trainees aimed at decreasing radiation exposure in three common pediatric fluoroscopic studies. A fluoroscopy competency check-off form was developed for radiology resident trainees performing pediatric procedures. Techniques used to limit radiation exposure for common pediatric radiologic studies were reviewed as part of the check-off process. Pediatric radiologists supervised each trainee until they demonstrated competence to independently perform three specified procedures. Radiation dose was recorded for the three procedures, upper GI (UGI), voiding cystourethrogram (VCUG) and oropharyngeal (OPM) exams, over 6 months preceding and 6 months following implementation of the competency check-off. The mean cumulative dose for each procedure was compared before and after implementation of competency check-off using a Kruskal-Wallis test. During the 12-month study period doses from 909 fluoroscopic procedures were recorded. In the 6 months preceding competency check-off implementation, procedures were performed by 24 radiology resident trainees including 171 UGI, 176 VCUG and 171 OPM exams. In the 6 months following competency check-off, 23 trainees performed 114 UGI, 145 VCUG and 132 OPM exams. After competency check-off implementation, a statistically significant reduction in average radiation dose was found for all three studies (P < 0.001). Median cumulative doses (mGy) were decreased by 33%, 36% and 13% for UGIs, VCUGs and OPMs, respectively. Implementation of a competency check-off for radiology resident trainees can reduce average radiation

  19. Pelvic Arterial Anatomy Relevant to Prostatic Artery Embolisation and Proposal for Angiographic Classification

    Energy Technology Data Exchange (ETDEWEB)

    Assis, André Moreira de, E-mail: andre.maa@gmail.com; Moreira, Airton Mota, E-mail: motamoreira@gmail.com; Paula Rodrigues, Vanessa Cristina de, E-mail: vanessapaular@yahoo.com.br [University of Sao Paulo Medical School, Interventional Radiology and Endovascular Surgery Department, Radiology Institute (Brazil); Harward, Sardis Honoria, E-mail: sardis.harward@merit.com [The Dartmouth Center for Health Care Delivery Science (United States); Antunes, Alberto Azoubel, E-mail: antunesuro@uol.com.br; Srougi, Miguel, E-mail: srougi@usp.br [University of Sao Paulo Medical School, Urology Department (Brazil); Carnevale, Francisco Cesar, E-mail: fcarnevale@uol.com.br [University of Sao Paulo Medical School, Interventional Radiology and Endovascular Surgery Department, Radiology Institute (Brazil)

    2015-08-15

    PurposeTo describe and categorize the angiographic findings regarding prostatic vascularization, propose an anatomic classification, and discuss its implications for the PAE procedure.MethodsAngiographic findings from 143 PAE procedures were reviewed retrospectively, and the origin of the inferior vesical artery (IVA) was classified into five subtypes as follows: type I: IVA originating from the anterior division of the internal iliac artery (IIA), from a common trunk with the superior vesical artery (SVA); type II: IVA originating from the anterior division of the IIA, inferior to the SVA origin; type III: IVA originating from the obturator artery; type IV: IVA originating from the internal pudendal artery; and type V: less common origins of the IVA. Incidences were calculated by percentage.ResultsTwo hundred eighty-six pelvic sides (n = 286) were analyzed, and 267 (93.3 %) were classified into I–IV types. Among them, the most common origin was type IV (n = 89, 31.1 %), followed by type I (n = 82, 28.7 %), type III (n = 54, 18.9 %), and type II (n = 42, 14.7 %). Type V anatomy was seen in 16 cases (5.6 %). Double vascularization, defined as two independent prostatic branches in one pelvic side, was seen in 23 cases (8.0 %).ConclusionsDespite the large number of possible anatomical variations of male pelvis, four main patterns corresponded to almost 95 % of the cases. Evaluation of anatomy in a systematic fashion, following a standard classification, will make PAE a faster, safer, and more effective procedure.

  20. Right ventricular ejection fraction - comparison of various angiographic and radionuclide approaches

    International Nuclear Information System (INIS)

    Schicha, H.; Tebbe, U.; Voth, E.; Sciagra, R.; Schultz, W.; Neuhaus, G.; Goettingen Univ.

    1987-01-01

    In 21 patients with various heart diseases RVEF was measured angiographically and by radionuclide ventriculography. Using biplane angiocardiography evaluation was performed by 7 different methods (Simpson's rule, Dogde, Arcilla, Ferlinz, Duebel). Using equilibrium RNV, evaluation was performed by 9 modifications of analysis. Problems were evident to separate the right atrium from the ventricle and to define the site of the pulmonary valve. The results show that when using the various methods of angiography considerable variations of the absolute volumes occur, but least so with RVEF. When using RNV with one single enddiastolic ROI, the RVEF was much too low. By means of the enddiastolic/endsystolic Double-ROI-method a good agreement with angiography was found, with correlation coefficients up to r=0.85. There was only a minor effect of background correction. (orig.) [de

  1. Angiographic examinations with the medium size technique (70 mm films)

    International Nuclear Information System (INIS)

    Heuck, F.; Reichardt, W.

    1981-01-01

    The applicability of medium-size technique was tested in angiographic examinations of thoracic and abdominal organs. By means of full-size image intensifiers it is possible to carry out organ angiography, and by means of a pace control mechanism for the patient transport, the angiography of the extremities can be realized. Examples are given illustrate the informational value in cases where the arial and venous vascular systems of organs and extremities are concerned. The particular advantages for functional analyses of organ circulatory systems in cases of angiography are described. Two factors of importance are pointed out: the reduction of the exposure to irradiation for the patient on the one hand, and the increasing film prices on the other hand. The authors demand to overcome the psychological problems arising in the medical working groups where the medium-size technique shall be introduced into routine diagnostics. (orig./APR) [de

  2. Angiographic prevalence and pattern of coronary artery disease in women.

    Science.gov (United States)

    Ezhumalai, Babu; Jayaraman, Balachander

    2014-01-01

    There are not many studies describing the prevalence and pattern of "coronary artery disease" (CAD) in women undergoing "coronary angiography" (CAG). Hence, uncertainty thrives with regard to the angiographic prevalence and pattern of CAD in women. Our objective was to study the prevalence and pattern of CAD among women undergoing CAG. Data of 500 women who underwent CAG for suspected CAD over 3 years were retrospectively analyzed. They were classified into young group (age right coronary artery. Bifurcation lesion involving distal left main coronary artery is the most prevalent pattern of LMD. There has been a change with regard to clinical presentation and onset of risk factors for CAD at young age, but the load of atherosclerotic burden and pattern of involvement of coronary arteries have not changed in women. Copyright © 2014 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.

  3. Stenting for symptomatic vertebral artery stenosis associated with bilateral carotid rate mirabile: The long-term clinical and angiographic outcome

    Energy Technology Data Exchange (ETDEWEB)

    Baek, Jang Hyun; Kim, Byung Moon [Dept. of Radiology, Severance Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2015-06-15

    Symptomatic vertebral artery (VA) stenosis associated with bilateral carotid rate mirabile (CRM) has not been reported. We report the long-term clinical and angiographic outcome after stenting for symptomatic VA stenosis in the patient with bilateral CRM. This report is the first case that symptomatic VA stenosis associated with bilateral CRM was treated with stenting.

  4. Stenting for symptomatic vertebral artery stenosis associated with bilateral carotid rate mirabile: The long-term clinical and angiographic outcome

    International Nuclear Information System (INIS)

    Baek, Jang Hyun; Kim, Byung Moon

    2015-01-01

    Symptomatic vertebral artery (VA) stenosis associated with bilateral carotid rate mirabile (CRM) has not been reported. We report the long-term clinical and angiographic outcome after stenting for symptomatic VA stenosis in the patient with bilateral CRM. This report is the first case that symptomatic VA stenosis associated with bilateral CRM was treated with stenting.

  5. Recurrent bleeding after arterial embolization in patients with hemoptysis : Comparison of angiographic findings and relapsing period

    International Nuclear Information System (INIS)

    Park, Sung Keun; Choi, Seok Jin; Choi, Gi Bok; Kim, Hae Yeon; Park, Auh Whan; Juhn, Jae Ryang; Cha, Seong Sook

    2001-01-01

    To describe the angiographic findings of patients with recurrent hemoptysis after bronchial artery embolization (BAE) according to the point at which relapse occurred. From 125 patients who underwent BAE due to hemoptysis between 1996 and 2000, we selected 18 of 23 who underwent additional BAE due to recurrent bleeding after initial BAE. Depending on the point at which relapse occurred, they were divided into two groups (I and ll, according to whether additional BAE was performed within two weeks of initial BAE or more than two weeks after this) We retrospectively compared the two groups in terms of angiographic findings, number of embolized arteries, and character of feeding arteries at initial and additional BAE. Nine patients in group I (additional BAE: n=10) and nine in group ll (additional BAE: n=13) were admitted for recurrent hemoptysis within two weeks of initial BAE and more than two weeks after this, respectively. In group I (n=29) and ll(n=31), angiography demonstrated two direct and 27 indirect, and two direct and 29 indirect signs of hemorrhage, respectiveIy. No statistically significant differences were observed (x 2 =0.005, ρ=0.945). Among the embolized feeder ressels in group I (n=30) there were 20 bronchial artery and 10 non bronchial systemic collaterals, while for group ll (n=35), the corresponding totals were 21 and 14. Again, no statistically significant differences were encountered(x 2 =0.308; ρ=0.579). In group I, feeders were newly developed in one case(10%), previously embolized in five(50%), and missed in four(40%), while in group two the corresponding figures were none, twelve(92.3%), and one(7.7%) No significant differences were noted, though the incidence of previously embolized feeders in Group ll was very high (x 2 =5.383, ρ=0.068). Among patients in whom hemoptysis after BAE recurred at different times, the angiographic findings and number of embolized arteries were not significantly different, but differences in the nature of the

  6. MR imaging findings of high-voltage electrical burns in the upper extremities: correlation with angiographic findings

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Gyung Kyu; Kang, Ik Won; Hwang, Dae Hyun; Min, Seon Jung; Han, You Mi (Dept. of Radiology, Hallym Univ. College of Medicine, Hangang Sacred Heart Hospital, Seoul (Korea, Republic of)); Suh, Kyung Jin (Dept. of Radiology, Dongguk Univ. College of Medicine, Gyeongju Hospital, Gyeongju (Korea, Republic of)), email: kyungjin.suh@gmail.com; Choi, Min Ho (Dept. of Internal Medicine, Hallym Univ. College of Medicine, Hangang Sacred Heart Hospital, Seoul (Korea, Republic of))

    2011-02-15

    Background: A high-voltage electrical burn is often associated with deep muscle injuries. Hidden, undetected deep muscle injuries have a tendency for progressive tissue necrosis, and this can lead to major amputations or sepsis. MRI has excellent soft tissue contrast and it may aid in differentiating the areas of viable deep muscle from the areas of non-viable deep muscle. Purpose: To describe the MR imaging findings of a high-voltage electrical burn in the upper extremity with emphasis on the usefulness of the gadolinium-enhanced MRI and to compare the MR imaging findings with angiography. Material and Methods: We retrospectively reviewed the imaging studies of six patients with high-voltage electrical burns who underwent both MRI and angiography at the burn center of our hospital from January 2005 to December 2009. The imaging features were evaluated for the involved locations, the MR signal intensity of the affected muscles, the MR enhancement pattern, the involved arteries and the angiographic findings (classified as normal, sluggish flow, stenosis or occlusion) of the angiography of the upper extremity. We assessed the relationship between the MR imaging findings and the angiographic findings. Results: The signal intensities of affected muscles were isointense or of slightly high signal intensity as compared with the adjacent unaffected skeletal muscle on the T1-weighted MR images. Affected muscles showed heterogenous high signal intensity relative to the adjacent unaffected skeletal muscle on the T2- weighted images. The gadolinium-enhanced T1-weighted images showed diffuse inhomogeneous enhancement or peripheral rim enhancement of the affected muscles. The angiographic findings of the arterial injuries showed complete occlusion in three patients, severe stenosis in two patients and sluggish flow in one patient. Of these, the five patients with complete occlusion or severe stenosis on angiography showed non-perfused and non-viable areas of edematous muscle on

  7. Fluoroscopically-guided transforaminal epidural steroid injection for the treatment of sciatica due to herniated nucleus pulposus

    International Nuclear Information System (INIS)

    Liu Xiao; Wang Jianhui; Duan Zhaohui; Xu Zhitao; Shu Xiaomin; Qiu Ronghua

    2009-01-01

    Objective: To discuss the therapeutic benefit of fluoroscopically-guided lumbar transforaminal epidural steroid injections (TFESI) in treating patients with sciatica due to a herniated nucleus pulposus. Methods: From October 2004 to November 2007, fluoroscopically-guided lumbar TFESI as performed in 79 patients (41 males and 38 females with a mean age of 45.75 years,ranged from 20 to 70 years) with sciatica due to a herniated nucleus pulposus. Patients had a symptomatic course of disease from 8 weeks to 22 years and showed no response to conservative treatment. The diagnosis was confirmed by computed tomography or magnetic resonance imaging. TFESI was performed at patient's request. Additional injections, up to 3 times, were given with an interval of 7 or 10 days. The injection medicine consisted of 25 mg of prednisolone acetate and (9-14) ml of 0.5% lidocaine. Patients were evaluated by an independent observer and received questionnaires before the initial injection and at 6,12 months after TFESI. Questionnaires included an eleven points visual analog scale (VAS) and a five points patient satisfaction scale. A successful outcome required a patient satisfaction scale score of 3 (very good) or 4(excellent) and a reduction on the VAS score of 2 or more points after TFESI. Pain relief was classified as 'excellent' when the pain was completely resolved or diminished by 5 points or more, as 'good' when a diminution of pain was 2 points or more, as 'fair' and 'poor' when a diminution of pain was 1 point or less, or even an increase in pain. Results: Twenty-nine patients received single injection, 22 patients received two, 15 patients received three and 13 patients received four times of injection, with a mean of 1.96 times per patient. The mean VAS scores were 6.5(ranged 3.5-9.5) before and 3.8(ranged 0-9.5) 6 months after the procedure. Pain relief was graded as excellent in 35 patients (44.3%), good in 26 patients(32.9%), fair in 10 patients(12.7%), and poor in 8

  8. Fluoroscopic removal of retrievable self-expandable metal stents in patients with malignant oesophageal strictures: Experience with a non-endoscopic removal system.

    Science.gov (United States)

    Kim, Pyeong Hwa; Song, Ho-Young; Park, Jung-Hoon; Zhou, Wei-Zhong; Na, Han Kyu; Cho, Young Chul; Jun, Eun Jung; Kim, Jun Ki; Kim, Guk Bae

    2017-03-01

    To evaluate clinical outcomes of fluoroscopic removal of retrievable self-expandable metal stents (SEMSs) for malignant oesophageal strictures, to compare clinical outcomes of three different removal techniques, and to identify predictive factors of successful removal by the standard technique (primary technical success). A total of 137 stents were removed from 128 patients with malignant oesophageal strictures. Primary overall technical success and removal-related complications were evaluated. Logistic regression models were constructed to identify predictive factors of primary technical success. Primary technical success rate was 78.8 % (108/137). Complications occurred in six (4.4 %) cases. Stent location in the upper oesophagus (P=0.004), stricture length over 8 cm (P=0.030), and proximal granulation tissue (Pstent location in the upper oesophagus, and stricture length over 8 cm were negative predictive factors for primary technical success by standard extraction and may require a modified removal technique. • Fluoroscopic retrievable SEMS removal is safe and effective. • Standard removal technique by traction is effective in the majority of patients. • Three negative predictive factors of primary technical success were identified. • Caution should be exercised during the removal in those situations. • Eversion technique is effective in cases of proximal granulation tissue.

  9. Angiographic characteristics of premature coronary artery disease in pakistan population; a prospective cross-sectional study

    International Nuclear Information System (INIS)

    Mustafa, B.; Rahman, H.U.

    2015-01-01

    Objective: To study the angiographic characteristics of premature coronary artery disease in our population. Methodology: From April 2014 to March 2015, coronary angiograms of 102 patients less than 40 years of age with a definitive diagnosis of ischemic heart disease were studied. Traditional risk factors of atherosclerosis were documented. Mode of presentation and symptoms were recorded along with angiographic findings of coronary artery disease severity, degree of coronary involvement, culprit vessel, lesion morphology, coronary dominance, coronary ectasia and left ventricular systolic function. Results: Mean age was 36.4 ± 4.1 years and 91% were male. Overall, left ventricular systolic function were fairly preserved (82%). 52% patients had single vessel CAD, 25% had double vessel while 19% had triple vessel coronary artery disease. Four patients had no luminal stenosis on coronary angiogram. LAD was the culprit vessel in 58.8%, RCA in 24.5% and left circumflex artery in 16.7% cases. More than 82% culprit lesions were severe or critical. 58% lesions were morphologically complex B2/C type while only 42% lesions were type A/B1. Coronary ectasia was seen in nearly 25% cases and all had ACS presentation. Right dominance was more common than left (57.8% vs 37.3%) while only 4.9% cases had dual posterior septal supply. Conclusion: Premature CAD in our population is acutely symptomatic, severe, complex (B2/C), single vessel disease. (author)

  10. Comparative functional scintigraphic and angiographic examination in pancreas diseases

    International Nuclear Information System (INIS)

    Mendizov, A.; Brilski, V.; Bozhiyanov, A.; Romanova, A.; Mardzhanov, I.; Glavincheva, I.; Meditsinska Akademiya, Sofia

    1979-01-01

    Pancreas scintigraphy with 75 seleno-methionine, pancreocimine-secretine test and selective abdominal angiography was carried out in patients with chronic pancreatitis, pancreas carcinoma and subjects without any pancreas diseases. Scintigraphic changes in pancreas was found in 95,6 per cent of the patients with chronic pancreatitis (136 patients), in 92 per cent of them with pancreas carcinoma (25 patients) and in 53,4 per cent from the subjects without pancreas diseases (30 examined). Pathological changes in pancreatic secretion was found in 93,4 per cent of the patients with chronic pancreatitis (105 patients), in 93,8 per cent of the subjects with pancreas carcinoma (32 patients) and only in 3,9 per cent from the examined without pancreatic diseases. The angiographic examination is informative mainly in case of tumours and cysts of the pancreas. The diagnostic potentialities of the separate methods for pancreas examination were critically assessed. The basic diagnostic problems in pancreas diseases are solved to a great extent with the combined examination with scintigraphy pancreocimine test and angiography (76 patients). (author)

  11. Fluoroscopically guided caudal epidural steroid injection for management of degenerative lumbar spinal stenosis: short-term and long-term results

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Joon Woo; Myung, Jae Sung; Kang, Heung Sik [Seoul National University Bundang Hospital, Department of Radiology, Seong Nam, Gyeongi-do (Korea); Park, Kun Woo; Yeom, Jin S. [Seoul National University Bundang Hospital, Department of Orthopaedic Surgery, Seong Nam, Gyeongi-do (Korea); Kim, Ki-Jeong; Kim, Hyun-Jib [Seoul National University Bundang Hospital, Department of Neurosurgery, Seong Nam, Gyeongi-do (Korea)

    2010-07-15

    To evaluate the short-term and long-term effects of fluoroscopically guided caudal epidural steroid injection (ESI) for the management of degenerative lumbar spinal stenosis (DLSS) and to analyze outcome predictors. All patients who underwent caudal ESI in 2006 for DLSS were included in the study. Response was based on chart documentation (aggravated, no change, slightly improved, much improved, no pain). In June 2009 telephone interviews were conducted, using formatted questions including the North American Spine Society (NASS) patient satisfaction scale. For short-term and long-term effects, age difference was evaluated by the Mann-Whitney U test, and gender, duration of symptoms, level of DLSS, spondylolisthesis, and previous operations were evaluated by Fisher's exact test. Two hundred and sixteen patients (male: female = 75:141; mean age 69.2 years; range 48{proportional_to}91 years) were included in the study. Improvements (slightly improved, much improved, no pain) were seen in 185 patients (85.6%) after an initial caudal ESI and in 189 patients (87.5%) after a series of caudal ESIs. Half of the patients (89/179, 49.8%) replied positively to the NASS patient satisfaction scale (1 or 2). There were no significant outcome predictors for either the short-term or the long-term responses. Fluoroscopically guided caudal ESI was effective for the management of DLSS (especially central canal stenosis) with excellent short-term and good long-term results, without significant outcome predictors. (orig.)

  12. CT Angiographic Demonstration of a Mesenteric Vessel 'Whirlpool' in Intestinal Malrotation and Midgut Volvulus: a Case Report

    International Nuclear Information System (INIS)

    Bozlar, Ugur; Ugurel, Mehmet Sahin; Ustunsoz, Bahri; Coskun, Unsal

    2008-01-01

    Although the color Doppler ultrasonography diagnosis of intestinal malrotation with midgut volvulus, based on the typical 'whirlpool' appearance of the mesenteric vascular structures is well-defined in the peer-reviewed literature, the combination of both the angiographic illustration of these findings and the contemporary state-of-the-art imaging techniques is lacking. We report the digital subtraction angiography and multidetector computed tomography angiography findings of a 37-year-old male with intestinal malrotation

  13. The child fluoroscopic examination in the I.I.-DR. Reduction of radiation exposure dose

    International Nuclear Information System (INIS)

    Endo, Takayuki

    2001-01-01

    This examination for I.I.-DR conditions was done for the purpose of reducing radiation exposure dose in child gastrointestinal fluoroscopy. Fluoroscopic apparatus used was Toshiba MAX-1000A with imaging recorder DDX-1000A. Dose was measured with a thimble ionization chamber Radcal Corporation Model 9015. Examinations for conditions were performed with the standard dose determined, the digital value 300, giving the plateau contrast ratio of acryl plate/barium sulfate. Reduction to about 10% dose (57 μGy/min for pulse fluoroscopy and 6.8 μGy/film for filming) relative to the usual method (764 μGy/min and 36.0 μGy/film, respectively) was found attained with additional filter of Al 0.5 mm + Cu 0.2 mm and IRIS diameter 100 with acryl thickness of 10 cm. Actual images of 6 months old baby were presented. (K.H.)

  14. Discrepancy between fluoroscopic arthrography and magnetic resonance arthrography in patients with arthroscopically confirmed supraspinatus tendon tears: The additional benefit of cine fluoroscopic arthrography images

    International Nuclear Information System (INIS)

    Hahn, Seok; Lee, Young Han; Suh, Jin Suck

    2016-01-01

    To determine the additional diagnostic benefits of fluoroscopic arthrography (FA) in patients with full-thickness supraspinatus tendon (SST) tears by comparing FA images with magnetic resonance arthrography (MRA) images. This study included FA and MRA images of 53 patients who were confirmed to have full-thickness SST tears by arthroscopy. In the FA analysis, the presence of contrast leakage into the subacromial-subdeltoid bursa was recorded. In the MRA analysis, contrast leakage, retraction of a torn tendon, width and length of the tear, and supraspinatus atrophy were evaluated. Patients were divided into the concordant group or the discordant group based on the presence of contrast leakage to compare the characteristics of SST tears. We used Fisher's exact test and two-sample t-test for the comparison. Of the 53 patients, 34 were included in the concordant group and 19 were included in the discordant group. In the concordant group, the grades of retraction were higher than those in the discordant group; the width and length of the tears were larger. Muscle atrophy was more severe in the concordant group. A full-thickness SST tear did not always exhibit contrast leakage on FA, particularly small SST tears or tears with low-grade retraction. FA can provide diagnostic information regarding the severity of full-thickness SST tears by itself

  15. Discrepancy between fluoroscopic arthrography and magnetic resonance arthrography in patients with arthroscopically confirmed supraspinatus tendon tears: The additional benefit of cine fluoroscopic arthrography images

    Energy Technology Data Exchange (ETDEWEB)

    Hahn, Seok; Lee, Young Han; Suh, Jin Suck [Dept. Radiology, Research Institute of Radiological Science, Medical Convergence Research Institute, and Severance Biomedical Science Institute, Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2016-12-15

    To determine the additional diagnostic benefits of fluoroscopic arthrography (FA) in patients with full-thickness supraspinatus tendon (SST) tears by comparing FA images with magnetic resonance arthrography (MRA) images. This study included FA and MRA images of 53 patients who were confirmed to have full-thickness SST tears by arthroscopy. In the FA analysis, the presence of contrast leakage into the subacromial-subdeltoid bursa was recorded. In the MRA analysis, contrast leakage, retraction of a torn tendon, width and length of the tear, and supraspinatus atrophy were evaluated. Patients were divided into the concordant group or the discordant group based on the presence of contrast leakage to compare the characteristics of SST tears. We used Fisher's exact test and two-sample t-test for the comparison. Of the 53 patients, 34 were included in the concordant group and 19 were included in the discordant group. In the concordant group, the grades of retraction were higher than those in the discordant group; the width and length of the tears were larger. Muscle atrophy was more severe in the concordant group. A full-thickness SST tear did not always exhibit contrast leakage on FA, particularly small SST tears or tears with low-grade retraction. FA can provide diagnostic information regarding the severity of full-thickness SST tears by itself.

  16. Simultaneous occurrence of a severe Morel-Lavallée lesion and gluteal muscle necrosis as a sequela of transcatheter angiographic embolization following pelvic fracture: a case report.

    Science.gov (United States)

    Shimizu, Takayoshi; Matsuda, Shuichi; Sakuragi, Atsushi; Tsukie, Tomio; Kawanabe, Keiichi

    2015-03-26

    Morel-Lavallée lesions are posttraumatic hemolymphatic collections caused by disruption of the interfascial planes between the subcutaneous soft tissue and muscle. Severe peripelvic Morel-Lavallée lesions have rarely been reported in the literature. By contrast, a number of cases of gluteal muscle necrosis following transcatheter angiographic embolization for pelvic fracture have been reported. Each entity can result in severe infection and sepsis, and the mortality rate in such cases is quite high. However, to date, no previous reports have described a case in which these life-threatening entities occurred simultaneously. A 32-year-old Asian man simultaneously developed severe peripelvic Morel-Lavallée lesions and gluteal muscle necrosis with sepsis following transcatheter angiographic embolization after an unstable pelvic fracture. Extremely large skin and soft tissue defects, which were untreatable with any commonly used flaps, were generated after repeated debridement. In addition, a deep-bone infection was suspected in his left fractured iliac bone, while motor function was almost completely lost in his left leg, possibly as a sequela of transcatheter angiographic embolization. As a result of his condition, a left hemipelvectomy was unavoidable. A pedicled fillet flap from his sacrificed left limb was used for the treatment of the defects and to provide a durable base for a prosthesis. Our patient survived and returned to his previous job 24 months after the surgery wearing a prosthetic left leg. As illustrated by the present case, severe peripelvic Morel-Lavallée lesions and gluteal muscle necrosis following transcatheter angiographic embolization can occur simultaneously after unstable pelvic fractures. Physicians should recognize that these entities can result in life-threatening sepsis and, therefore, should attempt to detect them as early as possible. When hemipelvectomy is unavoidable, a pedicled upper and lower leg in-continuity fillet flap may

  17. The availability of appropriately fitting personal protective aprons and jackets for angiographic and interventional radiology personnel

    International Nuclear Information System (INIS)

    Cremen, S.A.; McNulty, J.P.

    2014-01-01

    Purpose: This study explored the availability of personal protective equipment, lead or lead-free aprons or jackets, in angiographic and interventional radiology suites in the Republic of Ireland with a focus on the sizes available, appropriateness of fit and purchasing practices. Methods: All centres providing an angiographic or interventional radiology service in the Republic of Ireland were invited to participate with data being collected by means of a postal questionnaire exploring the above issues. Results: The mean number of aprons or jackets available across the centres who responded to the survey was 18.4 with the majority of these, 72%, being medium or large in size. Clinical specialists in three centres identified that there were insufficient aprons or jackets sized extra small or extra large within their departments and only one centre had a purchasing policy in place where individual staff were assigned a personal apron or jacket. Conclusion: Ill-fitting aprons or jackets will reduce the shielding provided to certain body regions by personal protective equipment. The use of over-sized aprons or jackets by staff is of particular concern based on the potential for inadvertent exposure to tissues where cancers may potentially be induced due to poor armhole fit. It is important to carefully consider purchasing practices and range of personal protective equipment sizes available in order to ensure that all staff receive the greatest possible protection from occupational radiation exposure

  18. TU-D-209-03: Alignment of the Patient Graphic Model Using Fluoroscopic Images for Skin Dose Mapping

    Energy Technology Data Exchange (ETDEWEB)

    Oines, A; Oines, A; Kilian-Meneghin, J; Karthikeyan, B; Rudin, S; Bednarek, D [University at Buffalo (SUNY) School of Med., Buffalo, NY (United States)

    2016-06-15

    Purpose: The Dose Tracking System (DTS) was developed to provide realtime feedback of skin dose and dose rate during interventional fluoroscopic procedures. A color map on a 3D graphic of the patient represents the cumulative dose distribution on the skin. Automated image correlation algorithms are described which use the fluoroscopic procedure images to align and scale the patient graphic for more accurate dose mapping. Methods: Currently, the DTS employs manual patient graphic selection and alignment. To improve the accuracy of dose mapping and automate the software, various methods are explored to extract information about the beam location and patient morphology from the procedure images. To match patient anatomy with a reference projection image, preprocessing is first used, including edge enhancement, edge detection, and contour detection. Template matching algorithms from OpenCV are then employed to find the location of the beam. Once a match is found, the reference graphic is scaled and rotated to fit the patient, using image registration correlation functions in Matlab. The algorithm runs correlation functions for all points and maps all correlation confidences to a surface map. The highest point of correlation is used for alignment and scaling. The transformation data is saved for later model scaling. Results: Anatomic recognition is used to find matching features between model and image and image registration correlation provides for alignment and scaling at any rotation angle with less than onesecond runtime, and at noise levels in excess of 150% of those found in normal procedures. Conclusion: The algorithm provides the necessary scaling and alignment tools to improve the accuracy of dose distribution mapping on the patient graphic with the DTS. Partial support from NIH Grant R01-EB002873 and Toshiba Medical Systems Corp.

  19. TU-D-209-03: Alignment of the Patient Graphic Model Using Fluoroscopic Images for Skin Dose Mapping

    International Nuclear Information System (INIS)

    Oines, A; Oines, A; Kilian-Meneghin, J; Karthikeyan, B; Rudin, S; Bednarek, D

    2016-01-01

    Purpose: The Dose Tracking System (DTS) was developed to provide realtime feedback of skin dose and dose rate during interventional fluoroscopic procedures. A color map on a 3D graphic of the patient represents the cumulative dose distribution on the skin. Automated image correlation algorithms are described which use the fluoroscopic procedure images to align and scale the patient graphic for more accurate dose mapping. Methods: Currently, the DTS employs manual patient graphic selection and alignment. To improve the accuracy of dose mapping and automate the software, various methods are explored to extract information about the beam location and patient morphology from the procedure images. To match patient anatomy with a reference projection image, preprocessing is first used, including edge enhancement, edge detection, and contour detection. Template matching algorithms from OpenCV are then employed to find the location of the beam. Once a match is found, the reference graphic is scaled and rotated to fit the patient, using image registration correlation functions in Matlab. The algorithm runs correlation functions for all points and maps all correlation confidences to a surface map. The highest point of correlation is used for alignment and scaling. The transformation data is saved for later model scaling. Results: Anatomic recognition is used to find matching features between model and image and image registration correlation provides for alignment and scaling at any rotation angle with less than onesecond runtime, and at noise levels in excess of 150% of those found in normal procedures. Conclusion: The algorithm provides the necessary scaling and alignment tools to improve the accuracy of dose distribution mapping on the patient graphic with the DTS. Partial support from NIH Grant R01-EB002873 and Toshiba Medical Systems Corp.

  20. Concomitant Intracranial and Lumbar Chronic Subdural Hematoma Treated by Fluoroscopic Guided Lumbar Puncture: A Case Report and Literature Review

    Science.gov (United States)

    ICHINOSE, Daisuke; TOCHIGI, Satoru; TANAKA, Toshihide; SUZUKI, Tomoya; TAKEI, Jun; HATANO, Keisuke; KAJIWARA, Ikki; MARUYAMA, Fumiaki; SAKAMOTO, Hiroki; HASEGAWA, Yuzuru; TANI, Satoshi; MURAYAMA, Yuichi

    2018-01-01

    A 40-year-old man presented with a severe headache, lower back pain, and lower abdominal pain 1 month after a head injury caused by falling. Computed tomography (CT) of the head demonstrated bilateral chronic subdural hematoma (CSDH) with a significant amount in the left frontoparietal region. At the same time, magnetic resonance imaging (MRI) of the lumbar spine also revealed CSDH from L2 to S1 level. A simple drainage for the intracranial CSDH on the left side was performed. Postoperatively, the headache was improved; however, the lower back and abdominal pain persisted. Aspiration of the liquefied spinal subdural hematoma was performed by a lumbar puncture under fluoroscopic guidance. The clinical symptoms were dramatically improved postoperatively. Concomitant intracranial and spinal CSDH is considerably rare so only 23 cases including the present case have been reported in the literature so far. The etiology and therapeutic strategy were discussed with a review of the literature. Therapeutic strategy is not established for these two concomitant lesions. Conservative follow-up was chosen for 14 cases, resulting in a favorable clinical outcome. Although surgical evacuation of lumbosacral CSDH was performed in seven cases, an alteration of cerebrospinal fluid (CSF) pressure following spinal surgery should be reminded because of the intracranial lesion. Since CSDH is well liquefied in both intracranial and spinal lesion, a less invasive approach is recommended not only for an intracranial lesion but also for spinal lesion. Fluoroscopic-guided lumbar puncture for lumbosacral CSDH following burr hole surgery for intracranial CSDH could be a recommended strategy. PMID:29479039

  1. Correlation of C-Reactive Protein and Cardiac Enzymes with Angiographic Severity of Coronary Artery Disease in Pakistani Patients with Acute Coronary Syndrome

    International Nuclear Information System (INIS)

    Saleem, A.; Ali, A.

    2017-01-01

    Objective: To determine the correlation of C-reactive protein (CRP) levels with the severity of coronary stenosis on angiography and the association of cardiac enzymes with the degree of stenosis in acute coronary syndrome (ACS) patients. Secondly, to compare association of angiographic severity of vascular stenosis with CRP in patients with ST segment elevation myocardial infarction (STEMI) and non-STEMI / Unstable angina (UA). Study Design: Prospective, descriptive study. Place and Duration of Study: Khan Research Laboratories (KRL) Hospital, from October 2014 to March 2015. Methodology: CRP was measured on diagnosis of ACS in 70 patients. Cardiac enzymes were measured 6 hours after the onset of chest pain. Angiographic scoring for degree of stenosis and number of culprit vessels was done. Two groups consisting of patients with STEMI (group 1) and with NSTEMI/UA (group 2) were made. Results: No correlation was found between CRP levels and angiographic stenosis in patients with ACS (r=0.162, p>0.05). No association was found between eosinophil count and severity of stenosis (p=0.88). Rise of cardiac enzymes and degree of coronary stenosis showed a positive correlation (p <0.001). There was significant difference in the means of coronary artery stenosis scores between the two groups (Gensini score of groups 1 and 2: 35.9 +- 4 and 14 +- 8, respectively) p<0.001, but there was no significant difference in CRP levels. Conclusion: CRP is a marker of inflammation in ACS rather than a risk factor for determining the severity of vascular stenosis. Rise in cardiac enzymes still grade high in predicting severity of vascular stenosis than eosinophil count or CRP levels. (author)

  2. Craniocervical artery dissection: MR imaging and MR angiographic findings

    International Nuclear Information System (INIS)

    Oelerich, M.; Schuierer, G.; Stoegbauer, F.; Kurlemann, G.; Schul, C.

    1999-01-01

    Dissection of the carotid and vertebral arteries is a not so uncommon cause of stroke and has to be considered as a differential diagnosis especially in younger patients. Therapeutic and prognostic implications are different from those in extracranial atherosclerotic disease. Dissection results from hemorrhage into the vessel wall usually between the layers of the media. Digital subtraction angiography (DSA) depicts the resulting luminal compromise that may reveal some typical, but not specific, findings. The same is true for non-invasive angiographic techniques such as time-of-flight magnetic resonance angiography (MRA) and computed tomography angiography (CTA), which have shown accurate results compared with DSA. The main advantage of these techniques is the direct visualization of the vessel wall confirming the intramural hematoma. This is achieved best with MR imaging due to the high signal of blood degradation products on T1- and T2-weighted images. Therefore, MRI in combination with MRA is presently the method of choice for initial diagnosis and follow-up of craniocervical artery dissection (CCAD). In some questionable cases, CTA is a non-invasive alternative that is independent of flow phenomena. (orig.)

  3. Craniocervical artery dissection: MR imaging and MR angiographic findings

    Energy Technology Data Exchange (ETDEWEB)

    Oelerich, M.; Schuierer, G. [Institute of Clinical Radiology, University of Muenster (Germany); Stoegbauer, F. [Department of Neurology, University of Muenster (Germany); Kurlemann, G. [Department of Pediatric Neurology, University of Muenster (Germany); Schul, C. [Department of Neurosurgery, University of Muenster (Germany)

    1999-09-01

    Dissection of the carotid and vertebral arteries is a not so uncommon cause of stroke and has to be considered as a differential diagnosis especially in younger patients. Therapeutic and prognostic implications are different from those in extracranial atherosclerotic disease. Dissection results from hemorrhage into the vessel wall usually between the layers of the media. Digital subtraction angiography (DSA) depicts the resulting luminal compromise that may reveal some typical, but not specific, findings. The same is true for non-invasive angiographic techniques such as time-of-flight magnetic resonance angiography (MRA) and computed tomography angiography (CTA), which have shown accurate results compared with DSA. The main advantage of these techniques is the direct visualization of the vessel wall confirming the intramural hematoma. This is achieved best with MR imaging due to the high signal of blood degradation products on T1- and T2-weighted images. Therefore, MRI in combination with MRA is presently the method of choice for initial diagnosis and follow-up of craniocervical artery dissection (CCAD). In some questionable cases, CTA is a non-invasive alternative that is independent of flow phenomena. (orig.) With 6 figs., 2 tabs., 33 refs.

  4. Intractable epistaxis: which arteries are responsible? An angiographic study.

    Science.gov (United States)

    de Bonnecaze, Guillaume; Gallois, Y; Chaynes, P; Bonneville, F; Dupret-Bories, A; Chantalat, E; Serrano, E

    2017-11-01

    Epistaxis constitutes a significant proportion of the Otolaryngologist's emergency workload. Optimal management differs in relation to the anatomic origin of the bleeding. The outcome of our study was to determine which artery(ies) could be considered as the cause of severe bleeding in the context of severe epistaxis. Fifty-five procedures of embolization preceded by angiography were reviewed. Medical records of interventionally treated patients were analysed for demographics, medical history, risk factors and clinical data. Angiographic findings were also assessed for active contrast extravasation (blush), vascular abnormality and embolised artery. Previous angiography showed an active contrast extravasation in only 20 procedures. The most common bleeding source was the sphenopalatine artery (SPA) followed by anterior ethmoïdal artery (AEA) and facial artery. Majority of multiple or bilateral extravasations occured in patients with systemic factors. A better understanding of the potential bleeding source might help and limit the risk of treatment failures. Our study confirms that the SPA is the most common cause of severe bleeding. We also emphasise the role of the AEA not only in traumatic context. Others arteries are rarely involved except in patients with comorbidities or frequent recurrences.

  5. Technical feasibility of 2D-3D coregistration for visualization of self-expandable microstents to facilitate coil embolization of broad-based intracranial aneurysms: an in vitro study

    Energy Technology Data Exchange (ETDEWEB)

    Richter, Gregor [University of Erlangen-Nuernberg, Department of Neuroradiology, Erlangen (Germany); Kreisklinikum Siegen, Department of Radiology and Neuroradiology, Siegen (Germany); Pfister, Marcus [Siemens AG, Healthcare Sector, Forchheim (Germany); Struffert, Tobias; Engelhorn, Tobias; Doelken, Marc; Doerfler, Arnd [University of Erlangen-Nuernberg, Department of Neuroradiology, Erlangen (Germany); Spiegel, Martin; Hornegger, Joachim [University of Erlangen, Department of Informatics 5, Erlangen (Germany)

    2009-12-15

    The use of self-expandable microstents for treatment of broad-based intracranial aneurysms is widely spread. However, poor fluoroscopic visibility of the stents remains disadvantageous during the coiling procedure. Flat detector angiographic computed tomography (ACT) provides high resolution imaging of microstents even though integration of this imaging modality in the neurointerventional workflow has not been widely reported. An acrylic glass model was used to simulate the situation of a broad-based sidewall aneurysm. After insertion of a self-expandable microstent, ACT was performed. The resulting 3D dataset of the Microstent was subsequently projected into a conventional 2D fluoroscopic roadmap. This 3D visualization of the stent supported the coil embolization procedure of the in vitro aneurysm. In vitro 2D-3D coregistration with integration of 3D ACT data of a self-expandable microstent in a conventional 2D roadmap is feasible. Unsatisfying stent visibility constrains clinical cases with complex parent vessel anatomy and challenging aneurysm geometry; hence, this technique potentially may be useful in such cases. In our opinion, the clinical feasibility and utility of this new technique should be verified in a clinical aneurysm embolization study series using 2D-3D coregistration. (orig.)

  6. Technical feasibility of 2D-3D coregistration for visualization of self-expandable microstents to facilitate coil embolization of broad-based intracranial aneurysms: an in vitro study

    International Nuclear Information System (INIS)

    Richter, Gregor; Pfister, Marcus; Struffert, Tobias; Engelhorn, Tobias; Doelken, Marc; Doerfler, Arnd; Spiegel, Martin; Hornegger, Joachim

    2009-01-01

    The use of self-expandable microstents for treatment of broad-based intracranial aneurysms is widely spread. However, poor fluoroscopic visibility of the stents remains disadvantageous during the coiling procedure. Flat detector angiographic computed tomography (ACT) provides high resolution imaging of microstents even though integration of this imaging modality in the neurointerventional workflow has not been widely reported. An acrylic glass model was used to simulate the situation of a broad-based sidewall aneurysm. After insertion of a self-expandable microstent, ACT was performed. The resulting 3D dataset of the Microstent was subsequently projected into a conventional 2D fluoroscopic roadmap. This 3D visualization of the stent supported the coil embolization procedure of the in vitro aneurysm. In vitro 2D-3D coregistration with integration of 3D ACT data of a self-expandable microstent in a conventional 2D roadmap is feasible. Unsatisfying stent visibility constrains clinical cases with complex parent vessel anatomy and challenging aneurysm geometry; hence, this technique potentially may be useful in such cases. In our opinion, the clinical feasibility and utility of this new technique should be verified in a clinical aneurysm embolization study series using 2D-3D coregistration. (orig.)

  7. Improving Technology for Vascular Imaging

    Science.gov (United States)

    Rana, Raman

    Neuro-endovascular image guided interventions (Neuro-EIGIs) is a minimally invasive procedure that require micro catheters and endovascular devices be inserted into the vasculature via an incision near the femoral artery and guided under low dose fluoroscopy to the vasculature of the head and neck. However, the endovascular devices used for the purpose are of very small size (stents are of the order of 50mum to 100mum) and the success of these EIGIs depends a lot on the accurate placement of these devices. In order to accurately place these devices inside the patient, the interventionalist should be able to see them clearly. Hence, high resolution capabilities are of immense importance in neuro-EIGIs. The high-resolution detectors, MAF-CCD and MAF-CMOS, at the Toshiba Stroke and Vascular Research Center at the University at Buffalo are capable of presenting improved images for better patient care. Focal spot of an x-ray tube plays an important role in performance of these high resolution detectors. The finite size of the focal spot results into the blurriness around the edges of the image of the object resulting in reduced spatial resolution. Hence, knowledge of accurate size of the focal spot of the x-ray tube is very essential for the evaluation of the total system performance. Importance of magnification and image detector blur deconvolution was demonstrated to carry out the more accurate measurement of x-ray focal spot using a pinhole camera. A 30 micron pinhole was used to obtain the focal spot images using flat panel detector (FPD) and different source to image distances (SIDs) were used to achieve different magnifications (3.16, 2.66 and 2.16). These focal spot images were deconvolved with a 2-D modulation transfer function (MTF), obtained using noise response (NR) method, to remove the detector blur present in the images. Using these corrected images, the accurate size of all the three focal spots were obtained and it was also established that effect of

  8. Radiation dose to the operator during fluoroscopically guided spine procedures

    Energy Technology Data Exchange (ETDEWEB)

    Roccatagliata, Luca; Pravata, Emanuele; Cianfoni, Alessandro [Department of Neuroradiology, Neurocenter of Southern Switzerland, Ospedale Regionale di Lugano, Lugano (Switzerland); Presilla, Stefano [Unita di Fisica Medica, Ente Ospedaliero Cantonale (EOC), Bellinzona (Switzerland)

    2017-09-15

    Fluoroscopy is widely used to guide diagnostic and therapeutic spine procedures. The purpose of this study was to quantify radiation incident on the operator (operator Air Kerma) during a wide range of fluoroscopy-guided spine procedures and its correlation with the amount of radiation incident on the patient (Kerma Area Product - KAP). We retrospectively included 57 consecutive fluoroscopically guided spine procedures. KAP [Gy cm{sup 2}] and total fluoroscopy time were recorded for each procedure. An electronic dosimeter recorded the operator Air Kerma [μGy] for each procedure. Operator Air Kerma for each procedure, correlation between KAP and operator Air Kerma, and between KAP and fluoroscopy time was obtained. Operator Air Kerma was widely variable across procedures, with median value of 6.4 μGy per procedure. Median fluoroscopy time and median KAP per procedure were 2.6 min and 4.7 Gy cm{sup 2}, respectively. There was correlation between operator Air Kerma and KAP (r{sup 2} = 0.60), with a slope of 1.6 μGy Air Kerma per unit Gy cm{sup 2} KAP incident on the patient and between fluoroscopy time and KAP (r{sup 2} = 0.63). Operator Air Kerma during individual fluoroscopy-guided spine procedures can be approximated from the commonly and readily available information of the total amount of radiation incident on the patient, measured as KAP. (orig.)

  9. Intracranial infective aneurysms presenting with haemorrhage: An analysis of angiographic findings, management and outcome

    International Nuclear Information System (INIS)

    Venkatesh, Sudhakar K.; Phadke, Rajendra V.; Kalode, Ravi R.; Kumar, Sunil; Jain, Vijendra K.

    2000-01-01

    AIM: This study is an analysis of angiographic findings in 17 patients with infective aneurysms who presented with intracranial haemorrhage and reviews the management and outcome in the context of the existing literature. MATERIALS AND METHODS: A retrospective study of infective aneurysms in 17 patients was carried out. Cranial angiography was performed in all patients. The location, size and outline of aneurysms were analysed. Ten patients were managed conservatively and six patients underwent surgery for the ruptured infective aneurysms and were followed up for a period of 35.8 months and 23 months, respectively. RESULTS: Twenty-two aneurysms were identified (five unruptured) in 17 patients. Twenty aneurysms (90.9%) were distal in location and two (9.1%) proximal. Sixty percent were in the posterior circulation with 55% in the posterior cerebral artery (PCA) territory, 27.3% in the middle cerebral artery (MCA) territory and 9.1% in the anterior cerebral artery (ACA) territory. Fourteen aneurysms were small (3-5 mm) and eight were medium sized (6-9 mm). 72.7% of aneurysms had irregular outline and 27.3% regular outline. Out of the 10 ruptured aneurysms managed conservatively, eight resolved. One patient died, presumably due to rebleed, and one had infarction due to parent vessel thrombosis. Six aneurysms were surgically managed with good results. Of the five unruptured aneurysms one was surgically managed and the remaining four conservatively managed patients did not bleed during follow-up. CONCLUSION: Patients with ruptured infective aneurysms fared well with medical management and the outcome in this series is better than that reported in literature. Patients on conservative management, however, need closer monitoring with angiographic follow-up. Active management is required with enlarging or persisting aneurysms. Venkatesh, S.K. (2000)

  10. Angiographic examinations of the circulatory development of living chick embryos

    International Nuclear Information System (INIS)

    Stoeter, P.; Buchhoecker, M.; Bruzek, W.; Drews, U.; Schulze, K.; Tuebingen Univ.; Tuebingen Univ.

    1980-01-01

    In chick embryos of an age of incubation of 5-14 days, the physiological development of the circulation and the morphological differentation of the arterical system were studied by intravital and postmortal angiography. For the examinations of the living embryos, a special radiographic and injection technique had to be developed. The contrast medium was injected into the umbilical veins and transported by the actions of the embryonic heart. Continuous ECG recordings showed no marked interference of the injections with the cardiac activity. According to the angiographic findings, the circulation is relatively fast within the main arteries, but the capillary perfusion is prolonged and lasts up to several minutes. The average circulatory velocity of the blood stream within the carotid artery increases parallel to the arterial enlargement, whereas the circulatory time decreases and the number of heart beats during the period of carotid opacification does not change to a great extent. By this, a steady transport of gas and nutritional material may be achieved in the growing arterial system. (orig.) [de

  11. Optimal use of directional coronary atherectomy is required to ensure long-term angiographic benefit: a study with matched procedural outcome after atherectomy and angioplasty

    NARCIS (Netherlands)

    V.A.W.M. Umans (Victor); D.T.J. Keane (David); R. Melkert (Rein); P.W.J.C. Serruys (Patrick); D.P. Foley (David); H. Boersma (Eric)

    1994-01-01

    textabstractOBJECTIVES. This study was designed to examine whether restenosis is related to the extent or mechanism of lumen improvement and to explore angiographic determinants of optimal atherectomy. BACKGROUND. Directional atherectomy induces a greater extent of immediate gain and late loss but

  12. Pediatric patient and staff dose measurements in barium meal fluoroscopic procedures

    Science.gov (United States)

    Filipov, D.; Schelin, H. R.; Denyak, V.; Paschuk, S. A.; Porto, L. E.; Ledesma, J. A.; Nascimento, E. X.; Legnani, A.; Andrade, M. E. A.; Khoury, H. J.

    2015-11-01

    This study investigates patient and staff dose measurements in pediatric barium meal series fluoroscopic procedures. It aims to analyze radiographic techniques, measure the air kerma-area product (PKA), and estimate the staff's eye lens, thyroid and hands equivalent doses. The procedures of 41 patients were studied, and PKA values were calculated using LiF:Mg,Ti thermoluminescent dosimeters (TLDs) positioned at the center of the patient's upper chest. Furthermore, LiF:Mg,Cu,P TLDs were used to estimate the equivalent doses. The results showed a discrepancy in the radiographic techniques when compared to the European Commission recommendations. Half of the results of the analyzed literature presented lower PKA and dose reference level values than the present study. The staff's equivalent doses strongly depends on the distance from the beam. A 55-cm distance can be considered satisfactory. However, a distance decrease of ~20% leads to, at least, two times higher equivalent doses. For eye lenses this dose is significantly greater than the annual limit set by the International Commission on Radiological Protection. In addition, the occupational doses were found to be much higher than in the literature. Changing the used radiographic techniques to the ones recommended by the European Communities, it is expected to achieve lower PKA values ​​and occupational doses.

  13. Patient doses from fluoroscopically guided cardiac procedures in pediatrics

    International Nuclear Information System (INIS)

    Martinez, L C; Vano, E; Gutierrez, F; Rodriguez, C; Gilarranz, R; Manzanas, M J

    2007-01-01

    Infants and children are a higher risk population for radiation cancer induction compared to adults. Although some values on pediatric patient doses for cardiac procedures have been reported, data to determine reference levels are scarce, especially when compared to those available for adults in diagnostic and therapeutic procedures. The aim of this study is to make a new contribution to the scarce published data in pediatric cardiac procedures and help in the determination of future dose reference levels. This paper presents a set of patient dose values, in terms of air kerma area product (KAP) and entrance surface air kerma (ESAK), measured in a pediatric cardiac catheterization laboratory equipped with a biplane x-ray system with dynamic flat panel detectors. Cardiologists were properly trained in radiation protection. The study includes 137 patients aged between 10 days and 16 years who underwent diagnostic catheterizations or therapeutic procedures. Demographic data and technical details of the procedures were also gathered. The x-ray system was submitted to a quality control programme, including the calibration of the transmission ionization chamber. The age distribution of the patients was 47 for 2 respectively for the four age bands. These KAP values increase by a factor of 8 when moving through the four age bands. The probability of a fatal cancer per fluoroscopically guided cardiac procedure is about 0.07%. Median values of ESAK for the four age bands were 46, 50, 56 and 163 mGy, which lie far below the threshold for deterministic effects on the skin. These dose values are lower than those published in previous papers

  14. Self-Expandable Metallic Stent for the Palliative Treatment of Obstructing Left-Sided Colorectal Cancer under Fluoroscopic Guidance: A Comparison of the Clinical Results according to Stent Diameter

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Pyeong Guk; Hong, Hyun Pyo; Choi, Yoon Jung; Lee, Min Hee; Park, Hae Won; Chung, Eun Chul [Kangbuk Samsung Hospital, Seoul (Korea, Republic of); Kim, Sam Soo [Kangwon National University College of Medicine, Chuncheon (Korea, Republic of)

    2010-03-15

    To evaluate the feasibility, effectiveness, and safety of self-expandable metallic stent for the palliative treatment of obstructing left-sided colorectal cancer under fluoroscopic guidance, and to compare results according to the stent diameter. Under fluoroscopic guidance, 31 self-expandable metallic stents were placed into 25 patients for palliative purposes. The rates of technical success, clinical success, complications associated with stent insertion, patient survival, and primary stent patency were evaluated. The results were also compared between two groups: 13 patients using stents with a diameter of 22 mm and 12 patients using stents with a diameter of 26 mm. The technical and clinical success rates were 93.5 and 90.3%, respectively. The complications included severe abdominal pain (6.5%), minor rectal bleeding (9.7%), stent migration (9.7%), and tumor ingrowth or overgrowth (9.7%). No statistical differences in technical were detected between the two groups for the clinical success rate and complication rates. The mean survival time was 5.5 +- 1.4 months. The primary stent patency rates were 91.3% at 5 months, 85.2% at 10 months, and 77.4% at 15 months. The mean period of stent patency was 12.4 +- 2.6 months. The mean period of primary stent patency was 16.4 +- 2.6 months in the 26 mm stent group, and significantly higher than 5.4 +- 1.4 months in the 22 mm stent group (p=0.031). A self-expandable metallic stent under fluoroscopic guidance, for the palliative treatment of obstructing left-sided colorectal cancer, was feasible and effective, and yielded good clinical results. The period of primary stent patency of the 26 mm stent group was longer than the 22 mm stent group, and the complication rate was not significantly different between the two stent groups

  15. Self-Expandable Metallic Stent for the Palliative Treatment of Obstructing Left-Sided Colorectal Cancer under Fluoroscopic Guidance: A Comparison of the Clinical Results according to Stent Diameter

    International Nuclear Information System (INIS)

    Kang, Pyeong Guk; Hong, Hyun Pyo; Choi, Yoon Jung; Lee, Min Hee; Park, Hae Won; Chung, Eun Chul; Kim, Sam Soo

    2010-01-01

    To evaluate the feasibility, effectiveness, and safety of self-expandable metallic stent for the palliative treatment of obstructing left-sided colorectal cancer under fluoroscopic guidance, and to compare results according to the stent diameter. Under fluoroscopic guidance, 31 self-expandable metallic stents were placed into 25 patients for palliative purposes. The rates of technical success, clinical success, complications associated with stent insertion, patient survival, and primary stent patency were evaluated. The results were also compared between two groups: 13 patients using stents with a diameter of 22 mm and 12 patients using stents with a diameter of 26 mm. The technical and clinical success rates were 93.5 and 90.3%, respectively. The complications included severe abdominal pain (6.5%), minor rectal bleeding (9.7%), stent migration (9.7%), and tumor ingrowth or overgrowth (9.7%). No statistical differences in technical were detected between the two groups for the clinical success rate and complication rates. The mean survival time was 5.5 ± 1.4 months. The primary stent patency rates were 91.3% at 5 months, 85.2% at 10 months, and 77.4% at 15 months. The mean period of stent patency was 12.4 ± 2.6 months. The mean period of primary stent patency was 16.4 ± 2.6 months in the 26 mm stent group, and significantly higher than 5.4 ± 1.4 months in the 22 mm stent group (p=0.031). A self-expandable metallic stent under fluoroscopic guidance, for the palliative treatment of obstructing left-sided colorectal cancer, was feasible and effective, and yielded good clinical results. The period of primary stent patency of the 26 mm stent group was longer than the 22 mm stent group, and the complication rate was not significantly different between the two stent groups

  16. Evaluation of the angiographic findings in pulmonary atresia

    International Nuclear Information System (INIS)

    Choe, Kyu Ok; Sul, Jun Hee; Lee, Seung Kyu; Cho, Bum Koo; Hong, Pill Whoon

    1986-01-01

    We studied the angiographic findings in 65 patients with congenital pulmonary atresia, ages 4 days to 14 years (mean 3.3 yrs), from 1981 to 1986 at Severance Hospital Yonsei University. 1. 6 had pulmonary atresia with an intact interventricular septum, 38 had it with cardiac anomaly Renodynamically simulating TOF, and 21 associated with more complicated cardiac anomalies. 2. In the group with an intact ventricular septum, 5 showed confluent intrapericardial pulmonary artery, all segmental pulmonary arteries connected to intrapericardial artery. 3. In the group simulating TOF, aorta arose from RV with or without overriding in 35. In 27 patients with confluent intrapericardial pulmonary artery, 23 had more than 10 segmental pulmonary arteries connected to intrapericardial artery and 5 had severely hypoplastic hilar pulmonary arteries. In 11 with non confluent intrapericardial pulmonary artery, 4 had more than 10 segmental pulmonary arteries connected to central pulmonary artery and 9 had severely hypoplastic hilar pulmonary arteries. 4. In the group associated with more complicated cardiac anomaly, included 8 patients with atrioventricular discordance, 7 with univentricular heart and 6 with tricuspid atresia. In 17 patients with confluent intrapericardial artery, 16 had more than 10 segmental pulmonary arteries connected to intrapericardial artery, one showed severe hypoplasia of hilar pulmonary arteries. In another 4 with non confluence, no one showed more than 10 segmental arteries connected to intrapericardial or hilar pulmonary artery.

  17. Feasibility of differential quantification of 3D temporomandibular kinematics during various oral activities using a cone-beam computed tomography-based 3D fluoroscopic method

    Directory of Open Access Journals (Sweden)

    Chien-Chih Chen

    2013-06-01

    Conclusion: A new CBCT-based 3D fluoroscopic method was proposed and shown to be capable of quantitatively differentiating TMJ movement patterns among complicated functional activities. It also enabled a complete description of the rigid-body mandibular motion and descriptions of as many reference points as needed for future clinical applications. It will be helpful for dental practice and for a better understanding of the functions of the TMJ.

  18. An assessment of methods for monitoring entrance surface dose in fluoroscopically guided interventional procedures

    International Nuclear Information System (INIS)

    Waite, J.C.; Fitzgerald, M.

    2001-01-01

    In the light of a growing awareness of the risks of inducing skin injuries as a consequence of fluoroscopically guided interventional procedures (FGIPs), this paper compares three methods of monitoring entrance surface dose (ESD). It also reports measurements of ESDs made during the period August 1998 to June 1999 on 137 patients undergoing cardiac, neurological and general FGIPs. Although the sample is small, the results reinforce the need for routine assessments to be made of ESDs in FGIPs. At present, the most reliable and accurate form of ESD measurement would seem to be arrays of TLDs. However, transducer based methods, although likely to be less accurate, have considerable advantages in relation to a continuous monitoring programme. It is also suggested that there may be the potential locally for threshold dose area product (DAP) values to be set for specific procedures. These could be used to provide early warning of the potential for skin injuries. (author)

  19. Fluoroscopically guided tunneled trans-caudal epidural catheter technique for opioid-free neonatal epidural analgesia.

    Science.gov (United States)

    Franklin, Andrew D; Hughes, Elisabeth M

    2016-06-01

    Epidural analgesia confers significant perioperative advantages to neonates undergoing surgical procedures but may be very technically challenging to place using a standard interlaminar loss-of-resistance to saline technique given the shallow depth of the epidural space. Thoracic epidural catheters placed via the caudal route may reduce the risk of direct neural injury from needle placement, but often pose higher risks of infection and/or improper positioning if placed without radiographic guidance. We present a detailed method of placing a fluoroscopically guided, tunneled transcaudal epidural catheter, which may reduce both of these risks. The accuracy and precision of this technique often provides adequate analgesia to allow for opioid-free epidural infusions as well as significant reductions in systemic opioids through the perioperative period. Opioid-free analgesia using a regional anesthetic technique allows for earlier extubation and reduced perioperative sedation, which may have a less deleterious neurocognitive effect on the developing brain of the neonate.

  20. Complications of acucise endopyelotomy.

    Science.gov (United States)

    Kim, F J; Herrell, S D; Jahoda, A E; Albala, D M

    1998-10-01

    Endoscopic management of ureteropelvic junction (UPJ) obstruction has a success rate of 80% to 86%. We have been performing a ureteral cutting balloon procedure under fluoroscopic control (Acucise endopyelotomy) for UPJ obstruction at Loyola University Medical Center since 1991. The overall success rate in 77 patients was 78%. All patients had a preoperative intravenous urogram or a retrograde pyelogram, but none had vascular imaging studies. Acucise endopyelotomy consisted of a posterolateral incision of the UPJ and placement of an endopyelotomy or double-J stent. Foley catheter placement at the end of the procedure demonstrated significant gross hematuria in three patients (4%). All three remained hemodynamically stable but with significant drops in postprocedure hemoglobin levels, which necessitated blood transfusion. Aggressive management included angiographic studies and embolization of lower-pole branching arteries in two patients (3%). One patient stopped bleeding after being given two units of blood. None of the patients required an open exploratory procedure. Although the risk of vascular injury is low with Acucise endopyelotomy, prolonged postoperative gross hematuria does mandate investigation and observation. Angiographic embolization appears to be the therapeutic modality of choice for patients with hemorrhagic complications after an Acucise endopyelotomy.

  1. Angiographic Embolization of a Postpartum Vulvovaginal Hematoma in a Patient with Situs Inversus Totalis: An Effective Second-Line Treatment

    Directory of Open Access Journals (Sweden)

    Elias M. Dahdouh

    2013-01-01

    Full Text Available Situs inversus totalis is a rare congenital anomaly where asymmetrical positioning of internal organs may affect the surgical and radiological management of certain conditions. Vulvovaginal hematoma is a life-threatening complication of vaginal delivery whose primary treatment usually consists of incision and drainage of the hematoma and ligation of the responsible vessels, followed by wound packing. Failure of these measures to control the bleeding was previously considered as an indication for laparotomy to perform bilateral hypogastric artery ligation and, if needed, a hysterectomy. Relative to major abdominal surgery, selective percutaneous angiographic embolization offers considerable advantages and significant less morbidity. Indeed, angiographic embolization is routinely used as a measure to control refractory pelvic bleeding, though the literature and experience in women with situs inversus totalis are scarce. In this paper, we report a case of postpartum vulvovaginal hematoma in a patient with situs inversus, refractory to conventional treatment, where arteriographic embolization was successfully used to control the bleeding. The management of this obstetrical complication and the use of this minimally invasive technique are also reviewed. To the best of our knowledge, this is the first report in the literature describing the feasibility of this technique in a patient with situs inversus totalis.

  2. A review of two methods used in the USA to assess HE during fluoroscopic-based radiology

    International Nuclear Information System (INIS)

    Craig Yoder, R.; Salasky, Mark R.

    2016-01-01

    Dosemeter results for ∼81 500 people performing fluoroscopic and interventional radiology procedures were examined to identify differences between groups monitored either by using two dosemeters, one placed at the collar above the apron and a second placed under the apron on the torso (EDE1) or by using one single dosemeter placed at the collar above the apron (EDE2). The median annual HE was 0.17 mSv for those monitored using the EDE1 protocol and 0.26 mSv for the group using the EDE2 protocol. The EDE2 method was used most frequently with the EDE1 method preferred for those more highly exposed. Approximately, 22 % of dosemeter results for EDE1 were inconsistent with expected norms based on over and under apron dosemeter relationships. (authors)

  3. Fluoroscopically guided automated gun biopsy of chest lesions: diagnostic accuracy and complications

    International Nuclear Information System (INIS)

    Oh, Hee Sul; Han, Young Min; Choi, Ki Chul and others

    1998-01-01

    To determine the diagnostic accuracy and frequency of complications of fluoroscopyguided transthoracic needle biopsy, using an automated gun biopsy system. We retrospectively reviewed 86 patients who underwent automated gun biopsy between October 1995 and October 1996. An 18-gauge cutting needle was used in all cases. All biopsies were performed under fluoroscopic guidance by one interventional radiologist. Tissue sufficient for histologic diagnosis was obtained in 73 of 86 biopsies(84.9%). Fifty-six lesions were malignent and 30 were benign. Sensitivity and diagnostic accuracy for malignant lesions were 87.5% and 87.5%, respectively while cell type specificity in malignant diagnosis was 91.7%(11/12). Sensitivity and diagnostic accuracy for benign lesions were 80.0% and 73.3%, respectively. Postbioptic pneumothorax occurred in three of 86 biopsies(3.5%), one of which required placement of a chest tube. Automated gun biopsy is a simple, safe method for the diagnosis of focal chest lesions. An automated biopsy device offers high diagnostic accuracy in casis involving malignant and benign lesions of the chest, and is particularly useful for determining malignant cell type and specific diagnosis of benign lesions.=20

  4. Fully automatic algorithm for the analysis of vessels in the angiographic image of the eye fundus

    Directory of Open Access Journals (Sweden)

    Koprowski Robert

    2012-06-01

    Full Text Available Abstract Background The available scientific literature contains descriptions of manual, semi-automated and automated methods for analysing angiographic images. The presented algorithms segment vessels calculating their tortuosity or number in a given area. We describe a statistical analysis of the inclination of the vessels in the fundus as related to their distance from the center of the optic disc. Methods The paper presents an automated method for analysing vessels which are found in angiographic images of the eye using a Matlab implemented algorithm. It performs filtration and convolution operations with suggested masks. The result is an image containing information on the location of vessels and their inclination angle in relation to the center of the optic disc. This is a new approach to the analysis of vessels whose usefulness has been confirmed in the diagnosis of hypertension. Results The proposed algorithm analyzed and processed the images of the eye fundus using a classifier in the form of decision trees. It enabled the proper classification of healthy patients and those with hypertension. The result is a very good separation of healthy subjects from the hypertensive ones: sensitivity - 83%, specificity - 100%, accuracy - 96%. This confirms a practical usefulness of the proposed method. Conclusions This paper presents an algorithm for the automatic analysis of morphological parameters of the fundus vessels. Such an analysis is performed during fluorescein angiography of the eye. The presented algorithm automatically calculates the global statistical features connected with both tortuosity of vessels and their total area or their number.

  5. Transbronchial lung biopsy without fluoroscopic guide in Tehran Imam Khomeini’s Hospital (1999

    Directory of Open Access Journals (Sweden)

    "Firoozbakhsh S

    2002-08-01

    Full Text Available Background: Transbronchial lung biopsy (TBLB is an attractive alternative to open lung biopsy as an initial diagnostic procedure for patients with diffuse parenchymal disease or localized densities beyond direct endoscopic vision. TBLB can be carried out safely without fluoroscopy in patients with diffuse lung disease. Since in our bronchoscopic department fluoroscopy is not available, we planned to evaluate the blind (without fluoroscopic guide TBLB being performed in our department to determine the success rate in obtaining lung tissue, the sensitivity of the procedure and the risk of complications. Materials and Methods: Sixty-Four TBLB were done in our department during a 6 month period (March-September 1999. Results: Lung tissue wasn’t detected in two (3.1 percent samples. Pathological results were helpful in 46 (71.9 percent cases. No evidence of hemoptysis was found after the procedure. Three (4.68 percent cases of pneumothorax was detected. Only one of them required chest tube (1.51 percent. Conclusion: We concluded that blind TBLB was successful in our department with rates of complications comparable to other approved centers.

  6. Quantitative assessment of angiogenesis in the chick embryo and its chorioallantoic membrane by computerised analysis of angiographic images

    International Nuclear Information System (INIS)

    Nikiforidis, G.; Papazafiropoulos, D.; Siablis, D.; Karnabatidis, D.; Hatjikondi, O.; Dimopoulos, J.

    1999-01-01

    We studied, in vivo, the angiogenesis process in the chick embryo and its chorioallantoic membrane (CAM) using digital subtraction angiography (DSA) in conjunction with computer-assisted image analysis. In a series of fertilised eggs, angiography was carried out at days 8, 10, 12 and 14 of embryonic development. The angiographic images were digitised and subsequently processed for a specific image analysis. A set of specific morphological parameters has been defined to allow an analytical characterisation of the vascularity status. Vessels were classified into three categories according to their diameter (50-100, 100-200, and >200 μm). The data were normalised and statistically evaluated. Graphs showing the development of angiogenesis were obtained. Total vascular area revealed a continuous rise, whereas, total vascular length increased until day 12 and then it started decreasing. These morphometric parameters in the first two vessel categories progressively increased throughout the entire period of development, whereas in the third category they increased until day 10 and then they started decreasing. By applying a vascular casting technique CAM vessels were visualised and compared with those extracted from the processed angiographic image. The comparison revealed that there is exact matching for the first two vessel categories (diameters higher than 100 μm) while the matching of the third category (diameters between 50 and 100 μm) is approximate

  7. CT Angiographic Demonstration of a Mesenteric Vessel 'Whirlpool' in Intestinal Malrotation and Midgut Volvulus: a Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Bozlar, Ugur; Ugurel, Mehmet Sahin; Ustunsoz, Bahri [Gulhane Military Medical Academy, Ankara (Turkmenistan); Coskun, Unsal [Gulhane Military Medical Academy, Turkish Armed Forces Rehabilitation Center, Ankara (Turkmenistan)

    2008-10-15

    Although the color Doppler ultrasonography diagnosis of intestinal malrotation with midgut volvulus, based on the typical 'whirlpool' appearance of the mesenteric vascular structures is well-defined in the peer-reviewed literature, the combination of both the angiographic illustration of these findings and the contemporary state-of-the-art imaging techniques is lacking. We report the digital subtraction angiography and multidetector computed tomography angiography findings of a 37-year-old male with intestinal malrotation.

  8. Exposition of the operator's eye lens and efficacy of radiation shielding in fluoroscopically guided interventions; Exposition der Augenlinse des Untersuchers und Effizienz der Strahlenschutzmittel bei fluoroskopischen Interventionen

    Energy Technology Data Exchange (ETDEWEB)

    Galster, M.; Adamus, R. [Klinikum Nuernberg-Nord, Nuernberg (Germany). Inst. fuer Diagnostische und Interventionelle Radiologie; Guhl, C. [Klinikum Nuernberg (Germany). Inst. fuer Medizinische Physik; Uder, M. [Erlangen Univ. (Germany). Radiologisches Inst.

    2013-05-15

    Purpose: Efficacy of radiation protection tools for the eye lens dose of the radiologist in fluoroscopic interventions. Materials and Methods: A patient phantom was exposed using a fluoroscopic system. Dose measurements were made at the eye location of the radiologist using an ionization chamber. The setting followed typical fluoroscopic interventions. The reduction of scattered radiation by the equipment-mounted shielding (undercouch drapes and overcouch top) was evaluated. The ceiling-suspended lead acrylic glass screen was tested in scattered radiation generated by a slab phantom. The protective properties of different lead glass goggles and lead acrylic visors were evaluated by thermoluminescence measurements on a head phantom in the primary beam. Results: The exposition of the lens of about 110 to 550 {mu}Sv during radiologic interventions is only slightly reduced by the undercouch drapes. Applying the top in addition to the drapes reduces the lens dose by a factor of 2 for PA projections. In 25 LAO the dose is reduced by a factor between 1.2 and 5. The highest doses were measured for AP angulations furthermore the efficacy of the equipment-mounted shielding is minimal. The ceiling-suspended lead screen reduced scatter by a factor of about 30. The lead glass goggles and visors reduced the lens dose up to a factor of 8 to 10. Depending on the specific design, the tested models are less effective especially for radiation from lateral with cranial angulation of the beam. Occasionally the visors even caused an increase of dose. Conclusion: The exposition of the eye lens can be kept below the new occupational limit recommended by the ICRP if the radiation shielding equipment is used consistently. (orig.)

  9. Quantification of the gravity-dependent change in the C-arm image center for image compensation in fluoroscopic spinal neuronavigation.

    Science.gov (United States)

    Hariri, S; Abbasi, H R; Chin, S; Steinberg, G; Shahidi, R

    2001-01-01

    In the quest to develop a viable, frameless spinal navigation system, many researchers are utilizing the C-arm fluoroscope. However, there is a significant problem with the C-arm that must be quantified: the gravity-dependent sag effect resulting from the geometry of the C-arm and aggravated by the inequity of weight at each end of the C-arm. This study quantified the C-arm sag effect, giving researchers the protocol and data needed to develop a program that accounts for this distortion. The development of spinal navigation algorithms that account for the C-arm sag effect should produce a more accurate spinal navigation system.

  10. Barbed micro-spikes for micro-scale biopsy

    Science.gov (United States)

    Byun, Sangwon; Lim, Jung-Min; Paik, Seung-Joon; Lee, Ahra; Koo, Kyo-in; Park, Sunkil; Park, Jaehong; Choi, Byoung-Doo; Seo, Jong Mo; Kim, Kyung-ah; Chung, Hum; Song, Si Young; Jeon, Doyoung; Cho, Dongil

    2005-06-01

    Single-crystal silicon planar micro-spikes with protruding barbs are developed for micro-scale biopsy and the feasibility of using the micro-spike as a micro-scale biopsy tool is evaluated for the first time. The fabrication process utilizes a deep silicon etch to define the micro-spike outline, resulting in protruding barbs of various shapes. Shanks of the fabricated micro-spikes are 3 mm long, 100 µm thick and 250 µm wide. Barbs protruding from micro-spike shanks facilitate the biopsy procedure by tearing off and retaining samples from target tissues. Micro-spikes with barbs successfully extracted tissue samples from the small intestines of the anesthetized pig, whereas micro-spikes without barbs failed to obtain a biopsy sample. Parylene coating can be applied to improve the biocompatibility of the micro-spike without deteriorating the biopsy function of the micro-spike. In addition, to show that the biopsy with the micro-spike can be applied to tissue analysis, samples obtained by micro-spikes were examined using immunofluorescent staining. Nuclei and F-actin of cells which are extracted by the micro-spike from a transwell were clearly visualized by immunofluorescent staining.

  11. Prognostic value of Angiographic Perfusion Score (APS) following percutaneous interventions in acute coronary syndromes.

    Science.gov (United States)

    Narain, V S; Fischer, L; Puri, A; Sethi, R; Dwivedi, S K

    2013-01-01

    Identifying reperfusion and predicting post procedure risk is important following Percutaneous Coronary Interventions (PCI). An Angiographic Perfusion Score (APS) combining TIMI flow (TFG) and myocardial perfusion (TMPG) grades before and after PCI can accurately measure both epicardial and myocardial perfusion and predict Major Adverse Cardiac Events (MACE). APS was calculated in 226 (88 ST elevation Myocardial Infarction (STEMI) and 138 Non STEMI) patients. Maximum score being 12, reperfusion was defined as failed: 0-3, partial: 4-9, and full APS: 10-12. Thirty day MACE were observed. APS identified reperfusion significantly more than TMPG alone (STEMI: 50.6% vs 11.8% (p APS group (1.8% vs 22.5%) (p APS detects more low risk reperfused patients, post PCI. Copyright © 2012. Published by Elsevier B.V.

  12. Search for Bs0 --> micro+ micro- and B0 --> micro+ micro- decays with 2 fb-1 of pp collisions.

    Science.gov (United States)

    Aaltonen, T; Adelman, J; Akimoto, T; Albrow, M G; Alvarez González, B; Amerio, S; Amidei, D; Anastassov, A; Annovi, A; Antos, J; Aoki, M; Apollinari, G; Apresyan, A; Arisawa, T; Artikov, A; Ashmanskas, W; Attal, A; Aurisano, A; Azfar, F; Azzi-Bacchetta, P; Azzurri, P; Bacchetta, N; Badgett, W; Barbaro-Galtieri, A; Barnes, V E; Barnett, B A; Baroiant, S; Bartsch, V; Bauer, G; Beauchemin, P-H; Bedeschi, F; Bednar, P; Behari, S; Bellettini, G; Bellinger, J; Belloni, A; Benjamin, D; Beretvas, A; Beringer, J; Berry, T; Bhatti, A; Binkley, M; Bisello, D; Bizjak, I; Blair, R E; Blocker, C; Blumenfeld, B; Bocci, A; Bodek, A; Boisvert, V; Bolla, G; Bolshov, A; Bortoletto, D; Boudreau, J; Boveia, A; Brau, B; Bridgeman, A; Brigliadori, L; Bromberg, C; Brubaker, E; Budagov, J; Budd, H S; Budd, S; Burkett, K; Busetto, G; Bussey, P; Buzatu, A; Byrum, K L; Cabrera, S; Campanelli, M; Campbell, M; Canelli, F; Canepa, A; Carlsmith, D; Carosi, R; Carrillo, S; Carron, S; Casal, B; Casarsa, M; Castro, A; Catastini, P; Cauz, D; Cavalli-Sforza, M; Cerri, A; Cerrito, L; Chang, S H; Chen, Y C; Chertok, M; Chiarelli, G; Chlachidze, G; Chlebana, F; Cho, K; Chokheli, D; Chou, J P; Choudalakis, G; Chuang, S H; Chung, K; Chung, W H; Chung, Y S; Ciobanu, C I; Ciocci, M A; Clark, A; Clark, D; Compostella, G; Convery, M E; Conway, J; Cooper, B; Copic, K; Cordelli, M; Cortiana, G; Crescioli, F; Cuenca Almenar, C; Cuevas, J; Culbertson, R; Cully, J C; Dagenhart, D; Datta, M; Davies, T; de Barbaro, P; De Cecco, S; Deisher, A; De Lentdecker, G; De Lorenzo, G; Dell'orso, M; Demortier, L; Deng, J; Deninno, M; De Pedis, D; Derwent, P F; Di Giovanni, G P; Dionisi, C; Di Ruzza, B; Dittmann, J R; D'Onofrio, M; Donati, S; Dong, P; Donini, J; Dorigo, T; Dube, S; Efron, J; Erbacher, R; Errede, D; Errede, S; Eusebi, R; Fang, H C; Farrington, S; Fedorko, W T; Feild, R G; Feindt, M; Fernandez, J P; Ferrazza, C; Field, R; Flanagan, G; Forrest, R; Forrester, S; Franklin, M; Freeman, J C; Furic, I; Gallinaro, M; Galyardt, J; Garberson, F; Garcia, J E; Garfinkel, A F; Genser, K; Gerberich, H; Gerdes, D; Giagu, S; Giakoumopolou, V; Giannetti, P; Gibson, K; Gimmell, J L; Ginsburg, C M; Giokaris, N; Giordani, M; Giromini, P; Giunta, M; Glagolev, V; Glenzinski, D; Gold, M; Goldschmidt, N; Golossanov, A; Gomez, G; Gomez-Ceballos, G; Goncharov, M; González, O; Gorelov, I; Goshaw, A T; Goulianos, K; Gresele, A; Grinstein, S; Grosso-Pilcher, C; Grundler, U; Guimaraes da Costa, J; Gunay-Unalan, Z; Haber, C; Hahn, K; Hahn, S R; Halkiadakis, E; Hamilton, A; Han, B-Y; Han, J Y; Handler, R; Happacher, F; Hara, K; Hare, D; Hare, M; Harper, S; Harr, R F; Harris, R M; Hartz, M; Hatakeyama, K; Hauser, J; Hays, C; Heck, M; Heijboer, A; Heinemann, B; Heinrich, J; Henderson, C; Herndon, M; Heuser, J; Hewamanage, S; Hidas, D; Hill, C S; Hirschbuehl, D; Hocker, A; Hou, S; Houlden, M; Hsu, S-C; Huffman, B T; Hughes, R E; Husemann, U; Huston, J; Incandela, J; Introzzi, G; Iori, M; Ivanov, A; Iyutin, B; James, E; Jayatilaka, B; Jeans, D; Jeon, E J; Jindariani, S; Johnson, W; Jones, M; Joo, K K; Jun, S Y; Jung, J E; Junk, T R; Kamon, T; Kar, D; Karchin, P E; Kato, Y; Kephart, R; Kerzel, U; Khotilovich, V; Kilminster, B; Kim, D H; Kim, H S; Kim, J E; Kim, M J; Kim, S B; Kim, S H; Kim, Y K; Kimura, N; Kirsch, L; Klimenko, S; Klute, M; Knuteson, B; Ko, B R; Koay, S A; Kondo, K; Kong, D J; Konigsberg, J; Korytov, A; Kotwal, A V; Kraus, J; Kreps, M; Kroll, J; Krumnack, N; Kruse, M; Krutelyov, V; Kubo, T; Kuhlmann, S E; Kuhr, T; Kulkarni, N P; Kusakabe, Y; Kwang, S; Laasanen, A T; Lai, S; Lami, S; Lammel, S; Lancaster, M; Lander, R L; Lannon, K; Lath, A; Latino, G; Lazzizzera, I; Lecompte, T; Lee, J; Lee, J; Lee, Y J; Lee, S W; Lefèvre, R; Leonardo, N; Leone, S; Levy, S; Lewis, J D; Lin, C; Lin, C S; Linacre, J; Lindgren, M; Lipeles, E; Lister, A; Litvintsev, D O; Liu, T; Lockyer, N S; Loginov, A; Loreti, M; Lovas, L; Lu, R-S; Lucchesi, D; Lueck, J; Luci, C; Lujan, P; Lukens, P; Lungu, G; Lyons, L; Lys, J; Lysak, R; Lytken, E; Mack, P; Macqueen, D; Madrak, R; Maeshima, K; Makhoul, K; Maki, T; Maksimovic, P; Malde, S; Malik, S; Manca, G; Manousakis, A; Margaroli, F; Marino, C; Marino, C P; Martin, A; Martin, M; Martin, V; Martínez, M; Martínez-Ballarín, R; Maruyama, T; Mastrandrea, P; Masubuchi, T; Mattson, M E; Mazzanti, P; McFarland, K S; McIntyre, P; McNulty, R; Mehta, A; Mehtala, P; Menzemer, S; Menzione, A; Merkel, P; Mesropian, C; Messina, A; Miao, T; Miladinovic, N; Miles, J; Miller, R; Mills, C; Milnik, M; Mitra, A; Mitselmakher, G; Miyake, H; Moed, S; Moggi, N; Moon, C S; Moore, R; Morello, M; Movilla Fernandez, P; Mülmenstädt, J; Mukherjee, A; Muller, Th; Mumford, R; Murat, P; Mussini, M; Nachtman, J; Nagai, Y; Nagano, A; Naganoma, J; Nakamura, K; Nakano, I; Napier, A; Necula, V; Neu, C; Neubauer, M S; Nielsen, J; Nodulman, L; Norman, M; Norniella, O; Nurse, E; Oh, S H; Oh, Y D; Oksuzian, I; Okusawa, T; Oldeman, R; Orava, R; Osterberg, K; Pagan Griso, S; Pagliarone, C; Palencia, E; Papadimitriou, V; Papaikonomou, A; Paramonov, A A; Parks, B; Pashapour, S; Patrick, J; Pauletta, G; Paulini, M; Paus, C; Pellett, D E; Penzo, A; Phillips, T J; Piacentino, G; Piedra, J; Pinera, L; Pitts, K; Plager, C; Pondrom, L; Portell, X; Poukhov, O; Pounder, N; Prakoshyn, F; Pronko, A; Proudfoot, J; Ptohos, F; Punzi, G; Pursley, J; Rademacker, J; Rahaman, A; Ramakrishnan, V; Ranjan, N; Redondo, I; Reisert, B; Rekovic, V; Renton, P; Rescigno, M; Richter, S; Rimondi, F; Ristori, L; Robson, A; Rodrigo, T; Rogers, E; Rolli, S; Roser, R; Rossi, M; Rossin, R; Roy, P; Ruiz, A; Russ, J; Rusu, V; Saarikko, H; Safonov, A; Sakumoto, W K; Salamanna, G; Saltó, O; Santi, L; Sarkar, S; Sartori, L; Sato, K; Savoy-Navarro, A; Scheidle, T; Schlabach, P; Schmidt, E E; Schmidt, M A; Schmidt, M P; Schmitt, M; Schwarz, T; Scodellaro, L; Scott, A L; Scribano, A; Scuri, F; Sedov, A; Seidel, S; Seiya, Y; Semenov, A; Sexton-Kennedy, L; Sfyria, A; Shalhout, S Z; Shapiro, M D; Shears, T; Shepard, P F; Sherman, D; Shimojima, M; Shochet, M; Shon, Y; Shreyber, I; Sidoti, A; Sinervo, P; Sisakyan, A; Slaughter, A J; Slaunwhite, J; Sliwa, K; Smith, J R; Snider, F D; Snihur, R; Soderberg, M; Soha, A; Somalwar, S; Sorin, V; Spalding, J; Spinella, F; Spreitzer, T; Squillacioti, P; Stanitzki, M; St Denis, R; Stelzer, B; Stelzer-Chilton, O; Stentz, D; Strologas, J; Stuart, D; Suh, J S; Sukhanov, A; Sun, H; Suslov, I; Suzuki, T; Taffard, A; Takashima, R; Takeuchi, Y; Tanaka, R; Tecchio, M; Teng, P K; Terashi, K; Thom, J; Thompson, A S; Thompson, G A; Thomson, E; Tipton, P; Tiwari, V; Tkaczyk, S; Toback, D; Tokar, S; Tollefson, K; Tomura, T; Tonelli, D; Torre, S; Torretta, D; Tourneur, S; Trischuk, W; Tu, Y; Turini, N; Ukegawa, F; Uozumi, S; Vallecorsa, S; van Remortel, N; Varganov, A; Vataga, E; Vázquez, F; Velev, G; Vellidis, C; Veszpremi, V; Vidal, M; Vidal, R; Vila, I; Vilar, R; Vine, T; Vogel, M; Volobouev, I; Volpi, G; Würthwein, F; Wagner, P; Wagner, R G; Wagner, R L; Wagner-Kuhr, J; Wagner, W; Wakisaka, T; Wallny, R; Wang, S M; Warburton, A; Waters, D; Weinberger, M; Wester, W C; Whitehouse, B; Whiteson, D; Wicklund, A B; Wicklund, E; Williams, G; Williams, H H; Wilson, P; Winer, B L; Wittich, P; Wolbers, S; Wolfe, C; Wright, T; Wu, X; Wynne, S M; Yagil, A; Yamamoto, K; Yamaoka, J; Yamashita, T; Yang, C; Yang, U K; Yang, Y C; Yao, W M; Yeh, G P; Yoh, J; Yorita, K; Yoshida, T; Yu, G B; Yu, I; Yu, S S; Yun, J C; Zanello, L; Zanetti, A; Zaw, I; Zhang, X; Zheng, Y; Zucchelli, S

    2008-03-14

    We have performed a search for B(s)(0) --> micro(+) micro(-) and B(0) --> micro(+) micro(-) decays in pp collisions at square root s = 1.96 TeV using 2 fb(-1) of integrated luminosity collected by the CDF II detector at the Fermilab Tevatron Collider. The observed number of B(s)(0) and B0 candidates is consistent with background expectations. The resulting upper limits on the branching fractions are B(B(s)0) --> micro(+) micro(-)) micro(+) micro(-))<1.8 x 10(-8) at 95% C.L.

  13. Comparison of conventional full spine radiographs and fluoroscopic scanning method in young patients with idiopathic scoliosis; Vergleich von konventioneller Wirbelsaeulenganzaufnahme und fluoroskopischer Scan-Methode bei jungen Patienten mit idiopathischer Skoliose

    Energy Technology Data Exchange (ETDEWEB)

    Schaefer, J.; Kottke, R.; Claussen, C. [Abt. fuer Radiologische Diagnostik, Universitaetsklinikum Tuebingen (Germany); Kluba, T.; Niemeyer, T.; Hahnfeldt, T. [Klinik und Poliklinik fuer Orthopaedie, Universitaetsklinikum Tuebingen (Germany); Vonthein, R. [Inst. fuer Medizinische Biometrie, Universitaetsklinikum Tuebingen (Germany); Kamm, K.F. [Philips Medizin Systeme GmbH, Hamburg (Germany)

    2005-08-01

    Purpose: evaluation of low-dose full spine radiographs using fluoroscopic images for the assessment of the Cobb angle measurement in patients with scoliosis. Material and methods: twenty-one consecutive patients (aged 10-27 years, mean age 14 years) with a conventional full spine examination (film speed class 800) underwent a follow-up exam using digital pulsed fluoroscopy (Multi Diagnost 4, Philips Medical Systems, Eindhoven, The Netherlands). The mean follow-up was 9 months. During a synchronized scan with a C-arm speed of 4 cm/sec fluoroscopic images were stored with a pulsed frequency of 3 images per second. The single images were merged and reconstructed to one image with the software easy spine (Philips medical Systems, Eindhoven, The Netherlands). The corresponding dose-area product values (DAP) of both methods were compared. Three independent observers assessed Cobb angles and image quality for each technique. Results: the mean DAP values for conventional imaging was 94.9 cGy x cm{sup 2} and for fluoroscopy 7.8 cGy x cm{sup 2}, respectively. A significant dose reduction of 91.8% (CI 91% to 95%) was calculated. The average absolute angle difference between the observers was found to be 2.7 for conventional imaging and 2.4 for the fluoroscopic method. Interobserver standard deviation of 2.9 was lower than the 5.3 for conventional images. Image quality was better in the conventional images. Conclusion: using the scanning method, we could achieve a mean reduction of the radiation dose of 92%, while the accuracy of the Cobb angle measurements was comparable for both techniques despite of reduced image quality of digital fluoroscopy. (orig.)

  14. MicroED data collection and processing

    Energy Technology Data Exchange (ETDEWEB)

    Hattne, Johan; Reyes, Francis E.; Nannenga, Brent L.; Shi, Dan; Cruz, M. Jason de la [Janelia Research Campus, Howard Hughes Medical Institute, Ashburn, VA 20147 (United States); Leslie, Andrew G. W. [Medical Research Council Laboratory of Molecular Biology, Cambridge (United Kingdom); Gonen, Tamir, E-mail: gonent@janelia.hhmi.org [Janelia Research Campus, Howard Hughes Medical Institute, Ashburn, VA 20147 (United States)

    2015-07-01

    The collection and processing of MicroED data are presented. MicroED, a method at the intersection of X-ray crystallography and electron cryo-microscopy, has rapidly progressed by exploiting advances in both fields and has already been successfully employed to determine the atomic structures of several proteins from sub-micron-sized, three-dimensional crystals. A major limiting factor in X-ray crystallography is the requirement for large and well ordered crystals. By permitting electron diffraction patterns to be collected from much smaller crystals, or even single well ordered domains of large crystals composed of several small mosaic blocks, MicroED has the potential to overcome the limiting size requirement and enable structural studies on difficult-to-crystallize samples. This communication details the steps for sample preparation, data collection and reduction necessary to obtain refined, high-resolution, three-dimensional models by MicroED, and presents some of its unique challenges.

  15. Micro-propulsion and micro-combustion; Micropropulsion microcombustion

    Energy Technology Data Exchange (ETDEWEB)

    Ribaud, Y.; Dessornes, O.

    2002-10-01

    The AAAF (french space and aeronautic association) organized at Paris a presentation on the micro-propulsion. The first part was devoted to the thermal micro-machines for micro drones, the second part to the micro-combustion applied to micro-turbines. (A.L.B.)

  16. Cancer mortality in women after repeated fluoroscopic examinations of the chest

    International Nuclear Information System (INIS)

    Boice, J.D.; Monson, R.R.; Rosenstein, M.

    1981-01-01

    Among 1,047 women fluoroscopically examined in average of 102 times during pneumothorax therapy for tuberculosis and followed up to 45 years (average . 27 yr), no increase in the total number of cancer deaths occurred when these women were compared to 717 women who received other treatments [relative risk (RR) . 0.8]. However, elevated risks of mortality from stomach cancer (RR . 2.3), rectal cancer (RR . 3.8), breast cancer (RR . 1.2), lung cancer (RR . 1.8), and leukemia (RR . 1.2) were observed, but none was statistically significant and all were based on very small numbers of deaths. These increases were balanced by decreases of genital cancer (RR . 0.2), pancreatic cancer (RR . 0.9), lymphoma (RR . 0.6), and all other cancers (RR . 0.1). Average cumulative absorbed doses were 110 rads for the lungs, 33 rads for the trunk, 13 rads for the active bone marrow, and 7 rads for the stomach. The following upper levels of excess risk could be excluded with 95% confidence: 3.5 deaths/10(6) woman-year (WY)-rad for lung cancer, 4.8 deaths/10(6) WY-rad for lymphoma, and 12 deaths/10(6) WY-rad for leukemia. These findings indicated that the carcinogenic effect of multiple low-dose X-ray exposures was not greater than that currently assumed

  17. Agreement between clinical estimation and a new quantitative analysis by Photoshop software in fundus and angiographic image variables.

    Science.gov (United States)

    Ramezani, Alireza; Ahmadieh, Hamid; Azarmina, Mohsen; Soheilian, Masoud; Dehghan, Mohammad H; Mohebbi, Mohammad R

    2009-12-01

    To evaluate the validity of a new method for the quantitative analysis of fundus or angiographic images using Photoshop 7.0 (Adobe, USA) software by comparing with clinical evaluation. Four hundred and eighteen fundus and angiographic images of diabetic patients were evaluated by three retina specialists and then by computing using Photoshop 7.0 software. Four variables were selected for comparison: amount of hard exudates (HE) on color pictures, amount of HE on red-free pictures, severity of leakage, and the size of the foveal avascular zone (FAZ). The coefficient of agreement (Kappa) between the two methods in the amount of HE on color and red-free photographs were 85% (0.69) and 79% (0.59), respectively. The agreement for severity of leakage was 72% (0.46). In the two methods for the evaluation of the FAZ size using the magic and lasso software tools, the agreement was 54% (0.09) and 89% (0.77), respectively. Agreement in the estimation of the FAZ size by the lasso magnetic tool was excellent and was almost as good in the quantification of HE on color and on red-free images. Considering the agreement of this new technique for the measurement of variables in fundus images using Photoshop software with the clinical evaluation, this method seems to have sufficient validity to be used for the quantitative analysis of HE, leakage, and FAZ size on the angiograms of diabetic patients.

  18. Angiographically borderline left main coronary artery lesions: correlation of transthoracic doppler echocardiography and intravascular ultrasound: a pilot study

    Directory of Open Access Journals (Sweden)

    Varga Albert

    2011-06-01

    Full Text Available Abstract Background the clinical decision making could be difficult in patients with borderline lesions (visually assessed stenosis severity of 30 to 50% of the left main coronary artery (LM. The aim of the study was to evaluate the relationship between transthoracic Doppler (TTDE peak diastolic flow velocity (PDV and intravascular ultrasound (IVUS measurements in the assessment of angiographically borderline LM lesions. Methods 27 patients (mean age 64 ± 8 years, 21 males with borderline LM stenosis referred for IVUS examination were included in the study. We performed standard IVUS with minimal lumen area (MLA and plaque burden (PB measurement and routine quantitative coronary angiography (QCA with diameter stenosis (%DS and area stenosis (%AS assessment in all. During TTDE, resting PDV was measured in the LM. Results interpretable Doppler signal could be obtained in 24 patients (88% feasibility; therefore these patients entered the final analysis. MLA was 7.1 ± 2.7 mm2. TTDE measured PDV correlated significantly with IVUS-derived MLA (r = -0.46, p 2 LM stenosis. Conclusion In angiographically borderline LM disease, resting PDV from transthoracic echocardiography is increased in presence of increased plaque burden by IVUS. TTDE evaluation might be a useful adjunct to other invasive and non-invasive methods in the assessment of borderline LM lesions. Further, large scale studies are needed to establish the exact cut-off value of PDV for routine clinical application.

  19. Multi-detector CT coronary angiographic findings of coronary-to-pulmonary artery fistula

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Jae Seok; Park, Eun Ah; Lim, Ji Yeon; Lee, Whal [Dept. of Radiology, Seoul National University Hospital, Seoul (Korea, Republic of); Park, Jae Hyung [Dept. of Radiology, Myongji Hospital, Seonam University College of Medicine, Goyang (Korea, Republic of)

    2017-01-15

    To evaluate multi-detector CT (MDCT) coronary angiographic findings of coronary-to-pulmonary artery fistula (CPAF). We retrospectively reviewed images of patients with CPAF from the coronary CT angiography (CCTA) database obtained with a 64-channel MDCT between January 2008 and March 2011. We analyzed the CCTA findings for feeding arteries, fistula, association with peripulmonary arterial aneurysms, and the presence of communication between the CPAF and bronchial arteries. Fifty-five of the 15042 (0.37%) patients were diagnosed with CPAFs. The feeding artery was single (n = 18) or multiple (n = 37). The fistula had a single drainage site (n = 54) or multiple drainage sites (n = 1). The mean diameter of the fistulous opening was 2.7 ± 1.4 mm. A peripulmonary arterial aneurysm was present in 24 (44%) patients. Communication between CPAF and bronchial arteries was present in eight (14.5%) patients. MDCT coronary angiography can provide comprehensive morphologic details on CPAF and may help in presurgical or preinterventional planning.

  20. Eye lens dosimetry for fluoroscopically guided clinical procedures: practical approaches to protection and dose monitoring

    International Nuclear Information System (INIS)

    Martin, Colin J.

    2016-01-01

    Doses to the eye lenses of clinicians undertaking fluoroscopically guided procedures can exceed the dose annual limit of 20 mSv, so optimisation of radiation protection is essential. Ceiling-suspended shields and disposable radiation absorbing pads can reduce eye dose by factors of 2-7. Lead glasses that shield against exposures from the side can lower doses by 2.5-4.5 times. Training in effective use of protective devices is an essential element in achieving good protection and acceptable eye doses. Effective methods for dose monitoring are required to identify protection issues. Dosemeters worn adjacent to the eye provide the better option for interventional clinicians, but an unprotected dosemeter worn at the neck will give an indication of eye dose that is adequate for most interventional staff. Potential requirements for protective devices and dose monitoring can be determined from risk assessments using generic values for dose linked to examination workload. (author)

  1. On-chip micro-power: three-dimensional structures for micro-batteries and micro-supercapacitors

    Science.gov (United States)

    Beidaghi, Majid; Wang, Chunlei

    2010-04-01

    With the miniaturization of portable electronic devices, there is a demand for micro-power source which can be integrated on the semiconductor chips. Various micro-batteries have been developed in recent years to generate or store the energy that is needed by microsystems. Micro-supercapacitors are also developed recently to couple with microbatteries and energy harvesting microsystems and provide the peak power. Increasing the capacity per footprint area of micro-batteries and micro-supercapacitors is a great challenge. One promising route is the manufacturing of three dimensional (3D) structures for these micro-devices. In this paper, the recent advances in fabrication of 3D structure for micro-batteries and micro-supercapacitors are briefly reviewed.

  2. Angiographic predictors of 3-year patency of bypass grafts implanted on the right coronary artery system: a prospective randomized comparison of gastroepiploic artery, saphenous vein, and right internal thoracic artery grafts.

    Science.gov (United States)

    Glineur, David; D'hoore, William; de Kerchove, Laurent; Noirhomme, Philippe; Price, Joel; Hanet, Claude; El Khoury, Gebrine

    2011-11-01

    Saphenous vein, in situ right gastroepiploic artery, and right internal thoracic artery grafts are routinely used to revascularize the right coronary artery. Little is known about the predictive value of objective preoperative angiographic parameters on midterm graft patency. We prospectively enrolled 210 consecutive patients undergoing coronary revascularization. Revascularization of the right coronary artery was randomly performed with the saphenous vein grafts in 81 patients and the right gastroepiploic artery in 92 patients. During the same study period, 37 patients received right coronary artery revascularization with the right internal thoracic artery used in a Y-composite fashion. All patients underwent a protocol-driven coronary angiogram 3 years after surgery. Preoperative angiographic parameters included minimum lumen diameter percent stenosis measured by quantitative angiography. A graft was considered "not functional" with patency scores of 0 to 2 and "functional" with patency scores of 3 or 4. Angiographic follow-up was 100% complete. A significant difference in the distribution of flow patterns was observed in the 3 groups. In multivariate analysis, the use of a saphenous vein graft was associated with superior graft functionality compared with the other conduits (odds ratio, 6.1; 95% confidence interval, 2.4-15). Graft function was negatively influenced by the minimum lumen diameter (odds ratio, 0.11; confidence interval, 0.05-0.25). In the right gastroepiploic artery and right internal thoracic artery groups, the proportion of functional grafts was higher when the minimum lumen diameter was below a threshold value in the third minimum lumen diameter quartile (0.64-1.30 mm). Preoperative angiography predicts graft patency in the right gastroepiploic artery and right internal thoracic artery, whereas the flow pattern in saphenous vein grafts is significantly less influenced by quantitative angiographic parameters. Copyright © 2011 The American

  3. Evaluation of the UF/NCI hybrid computational phantoms for use in organ dosimetry of pediatric patients undergoing fluoroscopically guided cardiac procedures

    Science.gov (United States)

    Marshall, Emily L.; Borrego, David; Tran, Trung; Fudge, James C.; Bolch, Wesley E.

    2018-03-01

    Epidemiologic data demonstrate that pediatric patients face a higher relative risk of radiation induced cancers than their adult counterparts at equivalent exposures. Infants and children with congenital heart defects are a critical patient population exposed to ionizing radiation during life-saving procedures. These patients will likely incur numerous procedures throughout their lifespan, each time increasing their cumulative radiation absorbed dose. As continued improvements in long-term prognosis of congenital heart defect patients is achieved, a better understanding of organ radiation dose following treatment becomes increasingly vital. Dosimetry of these patients can be accomplished using Monte Carlo radiation transport simulations, coupled with modern anatomical patient models. The aim of this study was to evaluate the performance of the University of Florida/National Cancer Institute (UF/NCI) pediatric hybrid computational phantom library for organ dose assessment of patients that have undergone fluoroscopically guided cardiac catheterizations. In this study, two types of simulations were modeled. A dose assessment was performed on 29 patient-specific voxel phantoms (taken as representing the patient’s true anatomy), height/weight-matched hybrid library phantoms, and age-matched reference phantoms. Two exposure studies were conducted for each phantom type. First, a parametric study was constructed by the attending pediatric interventional cardiologist at the University of Florida to model the range of parameters seen clinically. Second, four clinical cardiac procedures were simulated based upon internal logfiles captured by a Toshiba Infinix-i Cardiac Bi-Plane fluoroscopic unit. Performance of the phantom library was quantified by computing both the percent difference in individual organ doses, as well as the organ dose root mean square values for overall phantom assessment between the matched phantoms (UF/NCI library or reference) and the patient

  4. Fluoroscopic-guided primary single-step percutaneous gastrostomy. Initial results using the Freka {sup registered} GastroTube; Primaere einzeitige durchleuchtungsgesteuerte perkutane Gastrostomie (PG). Erste Ergebnisse mit dem Freka {sup registered} GastroTube

    Energy Technology Data Exchange (ETDEWEB)

    Hahne, J.D.; Schoennagel, B.P.; Arndt, C.; Bannas, P.; Koops, A.; Adam, G.; Habermann, C.R. [Universitaetsklinikum Hamburg-Eppendorf (Germany). Zentrum fuer Radiologie; Herrmann, J. [Universitaetsklinikum Hamburg-Eppendorf (Germany). Zentrum fuer Radiologie; Universitaetsklinikum Hamburg-Eppendorf (Germany). Abt. Paediatrische Radiologie

    2011-07-15

    Purpose: To determine the practicability and outcome of fluoroscopic-guided primary one-step treatment of percutaneous gastrostomy (PG) with the system Freka {sup registered} Gastro Tube (Fresenius Kabi, Germany). Materials and Methods: In 39 patients (mean age 62.7 {+-} 12.0 years), primary PG was performed based on clinical indication from August 2009 to April 2010. The intervention was performed by an experienced radiologist under aseptic conditions by direct puncture with Freka {sup registered} Gastro Tube under fluoroscopic guidance. The clinical data and outcome as well as any complications originated from the electronic archive of the University Medical Center Hamburg-Eppendorf. Results: The intervention was technically successful in all 39 patients. Within the mean follow-up time of 155.3 {+-} 73.6 days, 29 patients (74.4 %) did not experience complications. 10 patients (25.6 %) had to be revised. Complications manifested after a mean of 135.6 {+-} 61.2 days and mainly corresponded to accidental dislocation (50 %). One patient had to be surgically revised under suspicion of a malpositioned tube and suspected intestinal perforation. Clinically relevant wound infections were not detected. The total costs per patient were 553.17 Euro for our single-step treatment (OPS 5 - 431.x) vs. 963.69 Euro (OPS 5 - 431.x and OPS 8 - 123.0) for the recommended two-step treatment. Conclusion: Fluoroscopic-guided primary single-step treatment with Freka {sup registered} Gastro Tube system is feasible and not associated with an increased complication rate when compared to published literature applying a two-step treatment approach. Material costs as well as human and time resources could be significantly reduced using the single-step treatment. (orig.)

  5. Sustainable Micro-Manufacturing of Micro-Components via Micro Electrical Discharge Machining

    Directory of Open Access Journals (Sweden)

    Valeria Marrocco

    2011-12-01

    Full Text Available Micro-manufacturing emerged in the last years as a new engineering area with the potential of increasing peoples’ quality of life through the production of innovative micro-devices to be used, for example, in the biomedical, micro-electronics or telecommunication sectors. The possibility to decrease the energy consumption makes the micro-manufacturing extremely appealing in terms of environmental protection. However, despite this common belief that the micro-scale implies a higher sustainability compared to traditional manufacturing processes, recent research shows that some factors can make micro-manufacturing processes not as sustainable as expected. In particular, the use of rare raw materials and the need of higher purity of processes, to preserve product quality and manufacturing equipment, can be a source for additional environmental burden and process costs. Consequently, research is needed to optimize micro-manufacturing processes in order to guarantee the minimum consumption of raw materials, consumables and energy. In this paper, the experimental results obtained by the micro-electrical discharge machining (micro-EDM of micro-channels made on Ni–Cr–Mo steel is reported. The aim of such investigation is to shed a light on the relation and dependence between the material removal process, identified in the evaluation of material removal rate (MRR and tool wear ratio (TWR, and some of the most important technological parameters (i.e., open voltage, discharge current, pulse width and frequency, in order to experimentally quantify the material waste produced and optimize the technological process in order to decrease it.

  6. Percutaneous vertebroplasty with a high-quality rotational angiographic unit

    Energy Technology Data Exchange (ETDEWEB)

    Pedicelli, Alessandro [Department of Bioimaging and Radiological Sciences, Catholic University of Sacred Heart, Policl. A.Gemelli, l.go Gemelli 1, 00168 Rome (Italy)], E-mail: apedicelli@rm.unicatt.it; Rollo, Massimo [Department of Bioimaging and Radiological Sciences, Catholic University of Sacred Heart, Policl. A.Gemelli, l.go Gemelli 1, 00168 Rome (Italy)], E-mail: mrollo@rm.unicatt.it; Piano, Mariangela [Department of Bioimaging and Radiological Sciences, Catholic University of Sacred Heart, Policl. A.Gemelli, l.go Gemelli 1, 00168 Rome (Italy)], E-mail: mariangela.piano@gmail.com; Re, Thomas J. [Department of Bioimaging and Radiological Sciences, Catholic University of Sacred Heart, Policl. A.Gemelli, l.go Gemelli 1, 00168 Rome (Italy)], E-mail: tomjre@gmail.com; Cipriani, Maria C. [Department of Gerontology, Catholic University of Sacred Heart, Policl. A.Gemelli, l.go Gemelli 1, 00168 Rome (Italy)], E-mail: alexped@yahoo.com; Colosimo, Cesare [Department of Bioimaging and Radiological Sciences, Catholic University of Sacred Heart, Policl. A.Gemelli, l.go Gemelli 1, 00168 Rome (Italy)], E-mail: colosimo@rm.unicatt.it; Bonomo, Lorenzo [Department of Bioimaging and Radiological Sciences, Catholic University of Sacred Heart, Policl. A.Gemelli, l.go Gemelli 1, 00168 Rome (Italy)], E-mail: lbonomo@rm.unicatt.it

    2009-02-15

    We evaluated the reliability of a rotational angiographic unit (RA) with flat-panel detector as a single technique to guide percutaneous vertebroplasty (PVP) and for post-procedure assessment by 2D and 3D reformatted images. Fifty-five consecutive patients (104 vertebral bodies) were treated under RA fluoroscopy. Rotational acquisitions with 2D and 3D reconstruction were obtained in all patients for immediate post-procedure assessment. In complex cases, this technique was also used to evaluate the needle position during the procedure. All patients underwent CT scan after the procedure. RA and CT findings were compared. In all cases, a safe trans-pedicular access and an accurate control of the bone-cement injection were successfully performed with high-quality fluoroscopy, even at the thoracic levels and in case of vertebra plana. 2D and 3D rotational reconstructions permitted CT-like images that clearly showed needle position and were similar to CT findings in depicting intrasomatic implant-distribution. RA detected 40 cement leakages compared to 42 demonstrated by CT and showed overall 95% sensitivity and 100% specificity compared to CT for final post-procedure assessment. Our preliminary results suggest that high-quality RA is reliable and safe as a single technique for PVP guidance, control and post-procedure assessment. It permits fast and cost-effective procedures avoiding multi-modality imaging.

  7. Scattered radiation dose to radiologist's cornea, thyroid and gonads while performing some x-ray fluoroscopic investigations

    International Nuclear Information System (INIS)

    Chougle, Arun

    1993-01-01

    The mankind has been immensely benefited from discovery of X-ray and it has found wide spread application in diagnosis and treatment. Radiation is harmful and can produce somatic and genetic effects in the exposed person. International Commission on Radiation Protection (ICRP) has recommended a system of dose limitation based on principle of ALARA. All the efforts should be made to keep the radiation dose to the radiation worker as low as possible. Fluoroscopy gives maximum dose to the patient and staff and hence we have attempted to quantify the scattered radiation dose to the cornea, thyroid and gonads of the radiologist performing fluoroscopic examinations such as barium meal, barium swallow, barium enema, myelography, histerosalpingography and fracture reduction. Thermoluminescence dosimetry (TLD) method using CaSO 4 :Dy TLD disc was employed for these measurements. Use of lead apron has reduced the dose to radiologist's gonad. (author). 3 refs., 4 tabs

  8. Patient doses from fluoroscopically guided cardiac procedures in pediatrics

    Science.gov (United States)

    Martinez, L. C.; Vano, E.; Gutierrez, F.; Rodriguez, C.; Gilarranz, R.; Manzanas, M. J.

    2007-08-01

    Infants and children are a higher risk population for radiation cancer induction compared to adults. Although some values on pediatric patient doses for cardiac procedures have been reported, data to determine reference levels are scarce, especially when compared to those available for adults in diagnostic and therapeutic procedures. The aim of this study is to make a new contribution to the scarce published data in pediatric cardiac procedures and help in the determination of future dose reference levels. This paper presents a set of patient dose values, in terms of air kerma area product (KAP) and entrance surface air kerma (ESAK), measured in a pediatric cardiac catheterization laboratory equipped with a biplane x-ray system with dynamic flat panel detectors. Cardiologists were properly trained in radiation protection. The study includes 137 patients aged between 10 days and 16 years who underwent diagnostic catheterizations or therapeutic procedures. Demographic data and technical details of the procedures were also gathered. The x-ray system was submitted to a quality control programme, including the calibration of the transmission ionization chamber. The age distribution of the patients was 47 for <1 year; 52 for 1-<5 years; 25 for 5-<10 years and 13 for 10-<16 years. Median values of KAP were 1.9, 2.9, 4.5 and 15.4 Gy cm2 respectively for the four age bands. These KAP values increase by a factor of 8 when moving through the four age bands. The probability of a fatal cancer per fluoroscopically guided cardiac procedure is about 0.07%. Median values of ESAK for the four age bands were 46, 50, 56 and 163 mGy, which lie far below the threshold for deterministic effects on the skin. These dose values are lower than those published in previous papers.

  9. Applying a foil queue micro-electrode in micro-EDM to fabricate a 3D micro-structure

    Science.gov (United States)

    Xu, Bin; Guo, Kang; Wu, Xiao-yu; Lei, Jian-guo; Liang, Xiong; Guo, Deng-ji; Ma, Jiang; Cheng, Rong

    2018-05-01

    Applying a 3D micro-electrode in a micro electrical discharge machining (micro-EDM) can fabricate a 3D micro-structure with an up and down reciprocating method. However, this processing method has some shortcomings, such as a low success rate and a complex process for fabrication of 3D micro-electrodes. By focusing on these shortcomings, this paper proposed a novel 3D micro-EDM process based on the foil queue micro-electrode. Firstly, a 3D micro-electrode was discretized into several foil micro-electrodes and these foil micro-electrodes constituted a foil queue micro-electrode. Then, based on the planned process path, foil micro-electrodes were applied in micro-EDM sequentially and the micro-EDM results of each foil micro-electrode were able to superimpose the 3D micro-structure. However, the step effect will occur on the 3D micro-structure surface, which has an adverse effect on the 3D micro-structure. To tackle this problem, this paper proposes to reduce this adverse effect by rounded corner wear at the end of the foil micro-electrode and studies the impact of machining parameters on rounded corner wear and the step effect on the micro-structure surface. Finally, using a wire cutting voltage of 80 V, a current of 0.5 A and a pulse width modulation ratio of 1:4, the foil queue micro-electrode was fabricated by wire electrical discharge machining. Also, using a pulse width of 100 ns, a pulse interval of 200 ns, a voltage of 100 V and workpiece material of 304# stainless steel, the foil queue micro-electrode was applied in micro-EDM for processing of a 3D micro-structure with hemispherical features, which verified the feasibility of this process.

  10. Prevalence, Risk Factors, and Outcome of Myocardial Infarction with Angiographically Normal and Near-Normal Coronary Arteries: A Systematic Review and Meta-Analysis

    Directory of Open Access Journals (Sweden)

    Samad Ghaffari

    2016-12-01

    Full Text Available Context: Coronary artery diseases are mostly detected using angiographic methods demonstrating arteries status. Nevertheless, Myocardial Infarction (MI may occur in the presence of angiographically normal coronary arteries. Therefore, this study aimed to investigate the prevalence of MI with normal angiography and its possible etiologies in a systematic review. Evidence Acquisition: In this meta-analysis, the required data were collected from PubMed, Science Direct, Google Scholar, Scopus, Magiran, Scientific Information Database, and Medlib databases using the following keywords: “coronary angiograph”, “normal coronary arteries”, “near-normal coronary arteries”, “heart diseases”, “coronary artery disease”, “coronary disease”, “cardiac troponin I”, “Myocardial infarction”, “risk factor”, “prevalence”, “outcome”, and their Persian equivalents. Then, Comprehensive Meta-Analysis software, version 2 using randomized model was employed to determine the prevalence of each complication and perform the meta-analysis. P values less than 0.05 were considered to be statistically significant. Results: Totally, 20 studies including 139957 patients were entered into the analysis. The patients’ mean age was 47.62 ± 6.63 years and 64.4% of the patients were male. The prevalence of MI with normal or near-normal coronary arteries was 3.5% (CI = 95%, min = 2.2%, and max = 5.7%. Additionally, smoking and family history of cardiovascular diseases were the most important risk factors. The results showed no significant difference between MIs with normal angiography and 1- or 2-vessel involvement regarding the frequency of major adverse cardiac events (5.4% vs. 7.3%, P = 0.32. However, a significant difference was found between the patients with normal angiography and those with 3-vessel involvement in this regard (5.4% vs. 20.2%, P < 0.001. Conclusions: Although angiographic studies are required to assess the underlying

  11. Angiographic assessment of initial balloon angioplasty results.

    Science.gov (United States)

    Gardiner, Geoffrey A; Sullivan, Kevin L; Halpern, Ethan J; Parker, Laurence; Beck, Margaret; Bonn, Joseph; Levin, David C

    2004-10-01

    To determine the influence of three factors involved in the angiographic assessment of balloon angioplasty-interobserver variability, operator bias, and the definition used to determine success-on the primary (technical) results of angioplasty in the peripheral arteries. Percent stenosis in 107 lesions in lower-extremity arteries was graded by three independent, experienced vascular radiologists ("observers") before and after balloon angioplasty and their estimates were compared with the initial interpretations reported by the physician performing the procedure ("operator") and an automated quantitative computer analysis. Observer variability was measured with use of intraclass correlation coefficients and SD. Differences among the operator, observers, and the computer were analyzed with use of the Wilcoxon signed-rank test and analysis of variance. For each evaluator, the results in this series of lesions were interpreted with three different definitions of success. Estimation of residual stenosis varied by an average range of 22.76% with an average SD of 8.99. The intraclass correlation coefficients averaged 0.59 for residual stenosis after angioplasty for the three observers but decreased to 0.36 when the operator was included as the fourth evaluator. There was good to very good agreement among the three independent observers and the computer, but poor correlation with the operator (P definition of success was used. Significant differences among the operator, the three observers, and the computer were not present when the definition of success was based on less than 50% residual stenosis. Observer variability and bias in the subjective evaluation of peripheral angioplasty can have a significant influence on the reported initial success rates. This effect can be largely eliminated with the use of residual stenosis of less than 50% to define success. Otherwise, meaningful evaluation of angioplasty results will require independent panels of evaluators or

  12. Hepatic Rupture Caused by Hemolysis, Elevated Liver Enzyme, and Low Platelet Count Syndrome: A Case Report with Computed Tomographic and Conventional Angiographic Findings

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Cheong Bok; Ahn, Jae Hong; Choi, Soo Jung; Lee, Jong Hyeog; Park, Man Soo; Jung, Seung Mun; Ryu, Dae Sik [Dept. of Radiology, Asan Foundation, Gangneung Asan Hospital, University of Ulsan College of Medicine, Gangneung (Korea, Republic of)

    2013-03-15

    The authors recently obtained successful clinical outcome after embolization of the hepatic artery and right inferior phrenic artery in a pregnant patient with hemolysis, elevated liver enzyme, and low platelet count (HELLP) syndrome causing hepatic rupture. We report the computed tomographic and conventional angiographic findings in a case of HELLP syndrome, resulting in hepatic infarction and rupture with active bleeding.

  13. Structure of catalase determined by MicroED

    Science.gov (United States)

    Nannenga, Brent L; Shi, Dan; Hattne, Johan; Reyes, Francis E; Gonen, Tamir

    2014-01-01

    MicroED is a recently developed method that uses electron diffraction for structure determination from very small three-dimensional crystals of biological material. Previously we used a series of still diffraction patterns to determine the structure of lysozyme at 2.9 Å resolution with MicroED (Shi et al., 2013). Here we present the structure of bovine liver catalase determined from a single crystal at 3.2 Å resolution by MicroED. The data were collected by continuous rotation of the sample under constant exposure and were processed and refined using standard programs for X-ray crystallography. The ability of MicroED to determine the structure of bovine liver catalase, a protein that has long resisted atomic analysis by traditional electron crystallography, demonstrates the potential of this method for structure determination. DOI: http://dx.doi.org/10.7554/eLife.03600.001 PMID:25303172

  14. Contrast fluoroscopic evaluation of gastrointestinal transit times with and without the use of falconry hoods in red-tailed hawks (Buteo jamaicensis).

    Science.gov (United States)

    Doss, Grayson A; Williams, Jackie M; Mans, Christoph

    2017-11-01

    OBJECTIVE To evaluate gastrointestinal transit times in red-tailed hawks (Buteo jamaicensis) by use of contrast fluoroscopic imaging and investigate the effect of falconry hooding in these hawks on gastrointestinal transit time. DESIGN Prospective, randomized, blinded, complete crossover study. ANIMALS 9 healthy red-tailed hawks. PROCEDURES Hawks were gavage-fed a 30% weight-by-volume barium suspension (25 mL/kg [11.3 mL/lb]) into the crop. Fluoroscopic images were obtained at multiple time points after barium administration. Time to filling and emptying of various gastrointestinal tract organs and overall transit time were measured. The effect of hooding (hooded vs nonhooded) on these variables was assessed in a randomized complete crossover design. RESULTS In nonhooded birds, overall gastrointestinal transit time ranged from 30 to 180 minutes (mean ± SD, 100 ± 52 min). Time to complete crop emptying ranged from 30 to 180 minutes (83 ± 49 min). Contrast medium was present in the ventriculus in all birds within 5 minutes of administration and in the small intestines within 5 to 15 minutes (median, 5 min). Hooding of red-tailed hawks resulted in a significant delay of complete crop emptying (no hood, 83 ± 49 minutes; hood, 133 ± 48 minutes), but no significant effects of hooding were found on other measured variables. CONCLUSIONS AND CLINICAL RELEVANCE These results indicated that overall gastrointestinal transit times are faster in red-tailed hawks than has been reported for psittacines and that the use of a falconry hood in red-tailed hawks may result in delayed crop emptying. Hooding did not exert significant effects on overall gastrointestinal transit time in this raptorial species.

  15. A micro-coupling for micro mechanical systems

    Science.gov (United States)

    Li, Wei; Zhou, Zhixiong; Zhang, Bi; Xiao, Yunya

    2016-05-01

    The error motions of micro mechanical systems, such as micro-spindles, increase with the increasing of the rotational speed, which not only decreases the rotational accuracy, but also promotes instability and limits the maximum operational speed. One effective way to deal with it is to use micro-flexible couplings between the drive and driven shafts so as to reduce error motions of the driven shaft. But the conventional couplings, such as diaphragm couplings, elastomeric couplings, bellows couplings, and grooved couplings, etc, cannot be directly used because of their large and complicated structures. This study presents a novel micro-coupling that consists of a flexible coupling and a shape memory alloy (SMA)-based clamp for micro mechanical systems. It is monolithic and can be directly machined from a shaft. The study performs design optimization and provides manufacturing considerations, including thermo-mechanical training of the SMA ring for the desired Two-Way-Shape-Memory effect (TWSMe). A prototype micro-coupling and a prototype micro-spindle using the proposed coupling are fabricated and tested. The testing results show that the prototype micro-coupling can bear a torque of above 5 N • mm and an axial force of 8.5 N and be fitted with an SMA ring for clamping action at room temperature (15 °C) and unclamping action below-5 °C. At the same time, the prototype micro-coupling can work at a rotational speed of above 200 kr/min with the application to a high-speed precision micro-spindle. Moreover, the radial runout error of the artifact, as a substitute for the micro-tool, is less than 3 μm while that of turbine shaft is above 7 μm. It can be concluded that the micro-coupling successfully accommodates misalignment errors of the prototype micro-spindle. This research proposes a micro-coupling which is featured with an SMA ring, and it is designed to clamp two shafts, and has smooth transmission, simple assembly, compact structure, zero-maintenance and

  16. Proposed Optimal Fluoroscopic Targets for Cooled Radiofrequency Neurotomy of the Sacral Lateral Branches to Improve Clinical Outcomes: An Anatomical Study.

    Science.gov (United States)

    Stout, Alison; Dreyfuss, Paul; Swain, Nathan; Roberts, Shannon; Loh, Eldon; Agur, Anne

    2017-11-23

    Current sacroiliac joint (SIJ) cooled radiofrequency (RF) is based on fluoroscopic anatomy of lateral branches (LBs) in three specimens. Recent studies confirm significant variation in LB positions. To determine if common fluoroscopic needle placements for cooled SIJ RF are adequate to lesion all S1-3 LBs. If not, would different targets improve lesion accuracy? The LBs of 20 cadavers were dissected bilaterally (40 SIJs), and 26 G radiopaque wires were sutured to the LBs. With a 10-mm radius ruler centered at each foramen, standard targets were assessed, as judged by a clockface on the right, for S1 and S2 at 2:30, 4:00, and 5:30 positions and at S3 at 2:30 and 4:00. Mirror image targets were assessed on the left. Assuming an 8-mm lesion diameter, the percentage of LBs that would not be ablated for each level was determined. Imaging through the superior end plate of S1 was compared against segment specific (SS) imaging. Nine point four percent of LBs would not be ablated at S1 vs 0.99% at S2 vs 35% at S3, and 60% of the 40 SIJs would be completely denervated using current targets. SS imaging did not improve results. Alternate target locations could improve the miss rate to 2.8% at S1 and 0% at S3 and would ablate all LBs in 95% of SIJs. Using a conservative 8-mm lesion measurement, contemporary cooled RF needle targets are inadequate to lesion all target LBs. Modifications to current targets are recommended to increase the effectiveness of the procedure. © 2017 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  17. Micro Engineering

    DEFF Research Database (Denmark)

    Alting, Leo; Kimura, F.; Hansen, Hans Nørgaard

    2003-01-01

    The paper addresses the questions of how micro products are designed and how they are manufactured. Definitions of micro products and micro engineering are discussed and the presentation is aimed at describing typical issues, possibilities and tools regarding design of micro products. The implica......The paper addresses the questions of how micro products are designed and how they are manufactured. Definitions of micro products and micro engineering are discussed and the presentation is aimed at describing typical issues, possibilities and tools regarding design of micro products...

  18. C-arm cone-beam CT combined with a new electromagnetic navigation system for guidance of percutaneous needle biopsies. Initial clinical experience

    Energy Technology Data Exchange (ETDEWEB)

    Kickuth, R.; Reichling, C.; Bley, T.; Hahn, D.; Ritter, C. [University Hospital of Wuerzburg (Germany). Inst. of Diagnostic and Interventional Radiology

    2015-07-15

    To evaluate the feasibility and efficacy of C-arm fluoroscopic cone-beam computed tomography (CACT) in combination with a new electromagnetic tracking (EMT) system for needle guidance during percutaneous biopsies. 53 patients were referred for biopsy of thoracic (n = 19) and abdominal (n = 34) lesions. CT-like images of the anatomical region of interest (ROI) were generated using a flat panel-based angiographic system. These images were transmitted to an EMT system. A coaxial puncture needle with a sensor in its tip was connected with the navigation system and tracked into an electromagnetic field created via a field generator. Data generated within this field were merged with the CACT images. On a monitor both the anatomical ROI and needle tip position were displayed to enable precise needle insertion into the target. Through the coaxial needle, biopsy specimens for the histologic evaluation were extracted. Number of representative biopsy samples, number of core biopsies/patient, total procedure time, dose-area product, fluoroscopic time, and complications were recorded. 53 CACT/EMT-guided biopsy procedures were performed, 48 of which (91 %) yielded representative tissue samples. Four core biopsies were obtained from each patient. 40 (75 %) lesions were malignant and 13 (25 %) lesions were benign. The total procedure time was 9 ± 5 min (range, 3 - 23 min), fluoroscopic time was 0.8 ± 0.4 min (range, 0.4 - 2 min). The mean dose-area product (cGy cm{sup 2}) was 7373 (range, 895 - 26 904). The rate of complications (1 pneumothorax, 2 hemoptyses) was 6 %. CACT combined with EMT appears to be a feasible and effective technique for the guidance of percutaneous biopsies with a low rate of therapeutically relevant complications.

  19. C-arm cone-beam CT combined with a new electromagnetic navigation system for guidance of percutaneous needle biopsies. Initial clinical experience

    International Nuclear Information System (INIS)

    Kickuth, R.; Reichling, C.; Bley, T.; Hahn, D.; Ritter, C.

    2015-01-01

    To evaluate the feasibility and efficacy of C-arm fluoroscopic cone-beam computed tomography (CACT) in combination with a new electromagnetic tracking (EMT) system for needle guidance during percutaneous biopsies. 53 patients were referred for biopsy of thoracic (n = 19) and abdominal (n = 34) lesions. CT-like images of the anatomical region of interest (ROI) were generated using a flat panel-based angiographic system. These images were transmitted to an EMT system. A coaxial puncture needle with a sensor in its tip was connected with the navigation system and tracked into an electromagnetic field created via a field generator. Data generated within this field were merged with the CACT images. On a monitor both the anatomical ROI and needle tip position were displayed to enable precise needle insertion into the target. Through the coaxial needle, biopsy specimens for the histologic evaluation were extracted. Number of representative biopsy samples, number of core biopsies/patient, total procedure time, dose-area product, fluoroscopic time, and complications were recorded. 53 CACT/EMT-guided biopsy procedures were performed, 48 of which (91 %) yielded representative tissue samples. Four core biopsies were obtained from each patient. 40 (75 %) lesions were malignant and 13 (25 %) lesions were benign. The total procedure time was 9 ± 5 min (range, 3 - 23 min), fluoroscopic time was 0.8 ± 0.4 min (range, 0.4 - 2 min). The mean dose-area product (cGy cm 2 ) was 7373 (range, 895 - 26 904). The rate of complications (1 pneumothorax, 2 hemoptyses) was 6 %. CACT combined with EMT appears to be a feasible and effective technique for the guidance of percutaneous biopsies with a low rate of therapeutically relevant complications.

  20. Medical radiation safety in the angiography room

    International Nuclear Information System (INIS)

    Kudou, Tamaki

    2011-01-01

    Author's efforts for angiographic procedure and technique aiming to reduce patient's exposure are described on a case with radiation skin hazard and on considerations of regulations and investigations. The case is a male patient (45 years old at the first intracardiac catheter examination, stature 164 cm, body wt. 116 kg), who, due to the diagnosis of angina pectoris and cardiac infarction, has the 5-year history of 5 coronary angiography (CAG), 6 percutaneous coronary intervention (PCI) and 1 off-pump coronary arterial bypass grafting (CABG). Because of serious skin injury and pain development after later PCI (172.2 min) (Oct. 2006) and their exacerbation after the latest PCI (27.1 min) (Apr. 2007), skin transplantation is conducted (Nov.). The exposure dose at the later PCI above is estimated to be around 12 Gy. Based on the case, consideration is made on regulatory recommendations by FDA, IAEA, ICRP, and investigational results of fluoroscopic mode vs dose by members of Japanese Circulatory Technology. With those references where the fluoroscopy at 20 mGy/min is assumed, the dose 12 Gy estimated above is thought to be resulted from the fluoroscopic dose >50 mGy/min within about 4 hr. To reduce the exposure, the author gives 11 items to be noted in interventional radiology: short fluoroscopic time, low rate pulse, minimal acquisition, use of additional filter, dose optimization, long distance between focus and skin, short distance between image intensifier (I.I.) and/or flat panel detector (FPD), minimal field, to avoid the excess inch-up, continuous maintenance of equipment, and record/preservation of the dose indicated by the machine. (T.T.)

  1. Feasibility of Using Intravascular Ultrasonography for Assessment of Giant Cavernous Aneurysm after Endovascular Treatment: A Technical Report

    Science.gov (United States)

    Majidi, Shahram; Grigoryan, Mikayel; Tekle, Wondwossen G; Watanabe, Masaki; Qureshi, Adnan I

    2012-01-01

    Introduction Intravascular ultrasonography (IVUS) has been shown as a valuable adjunct imaging tool during endovascular procedures but its value in detection of any recurrence during follow up after endovascular coil embolization of large and giant intracranial aneurysms is not reported. Methods A 41 years old man who had been treated using stent assisted coil embolization for cavernous segment aneurysm of the left internal carotid artery underwent 60 month angiographic follow up. Concurrently, IVUS catheter was advanced under fluoroscopic guidance inside the cavernous portion of the left internal carotid artery. Then IVUS images were used to visualize the stent, coil loops, and aneurysm neck. Results The angiographic images were limited because of superimposition of the aneurysm on the parent vessel in all projections. IVUS images demonstrated that the stent was patent along its whole length and there was no sign of stent deformity or in-stent thrombosis. Loops of the coil were visualized as hyperechoic signals inside the aneurysm and there was no sign of herniated loops of coil inside the stent. Conclusion In this case report, we observed that adjunct use of IVUS can provide valuable information not ascertained by angiography during follow up assessment of coil embolized aneurysm. PMID:22737259

  2. Time to Angiographic Reperfusion and Clinical Outcome after Acute Ischemic Stroke in the Interventional Management of Stroke Phase III (IMS III) Trial: A Validation Study

    Science.gov (United States)

    Khatri, Pooja; Yeatts, Sharon D.; Mazighi, Mikael; Broderick, Joseph P.; Liebeskind, David S.; Demchuk, Andrew M.; Amarenco, Pierre; Carrozzella, Janice; Spilker, Judith; Foster, Lydia D.; Goyal, Mayank; Hill, Michael D.; Palesch, Yuko Y.; Jauch, Edward C.; Haley, E. Clarke; Vagal, Achala; Tomsick, Thomas A.

    2014-01-01

    BACKGROUND The IMS III Trial did not demonstrate clinical benefit of the endovascular approach compared to IV rt-PA alone for moderate or severe ischemic strokes (NIHSS≥8) enrolled within three hours of stroke onset. Late reperfusion of tissue that is no longer salvageable may be one explanation, as suggested by prior exploratory studies showing an association between time to reperfusion and good clinical outcome. We sought to validate this relationship in the large-scale IMS III trial, and consider its implications for future endovascular trials. METHODS The analysis consisted of the endovascular cohort with proximal arterial occlusions in the anterior circulation that achieved angiographic reperfusion (TICI 2–3) during the endovascular procedure (within 7 hours from the onset of symptoms). Logistic regression was used to model good clinical outcome (90-day modified Rankin 0–2) as a function of the time to reperfusion, and prespecified variables were considered for adjustment. FINDINGS Among 240 proximal vessel occlusions, angiographic reperfusion (TICI 2–3) was achieved in 182 (76%). Mean time to reperfusion was 325 minutes (range 180–418 minutes). Longer time for reperfusion was associated with a decreased likelihood of good clinical outcome (RR [95% CI] for every 30 minute delay: unadjusted 0·85 [0·77–0·94]; adjusted 0·88 [0·80–0·98]). INTERPRETATION We confirm that delay in time to angiographic reperfusion leads to a decreased likelihood of good clinical outcome. Achieving rapid reperfusion may be critical for the successes of future acute endovascular trials. FUNDING: NIH/NINDS (study sponsor), Genentech Inc. (study drug - intra-arterial t-PA), EKOS Corp. (device), Concentric Inc. (device), Cordis Neurovascular, Inc. (device), and Boehringer Ingelheim (European Investigator Meeting support). PMID:24784550

  3. The relationship between cerebral infarction on MR and angiographic findings in moyamoya disease: significance of the posterior circulation

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Eun Ja; Song, Soon Young [College of Medicine, Kwangdong Univ., Koyang (Korea, Republic of); Yu, Won Jong; Jung, So Lyung; Chung, Bong Gak; Kag, Si Won [College of Medicine, The Catholic Univ. of Korea, Seoul (Korea, Republic of); Kim, Man Deuk [College of Medicine, Pochon CHA Univ., Pochon (Korea, Republic of)

    2002-06-01

    To investigate the relationship between changes in the posterior and anterior circulation, as seen at angiography, and the frequency and extent of cerebral infarction revealed by MR imaging in moyamoya disease. This study involved 34 patients (22 females and 12 males, aged 2-52 years) in whom cerebral angiography revealed the presence of moyamoya disease (bilateral; unilateral= 24:10; total hemispheres=58) and who also underwent brain MR imaging. To evaluate the angiographic findings, we applied each angiographic staging system to the anterior and posterior circulation. Leptomeningeal collateral circulation from the cortical branches of the posterior cerebral artery (PCA) was also assigned one of four grades. At MR imaging, areas of cerebral cortical or subcortical infarction in the hemisphere were divided into six zones. White matter and basal ganglionic infarction, ventricular dilatation, cortical atrophy, and hemorrhagic lesions were also evaluated. To demonstrate the statistical significance of the relationship between the angiographic and the MR findings, both the Mantel-Haenszel chi-square test for trend and the chi-square test were used. The degree of steno-occlusive PCA change correlated significantly with the internal carotid artery (ICA) stage (p<0.0001). As PCA stages advanced, the degree of leptomeningeal collaterals from the PCA decreased significantly (P<0.0001), but ICA stages were not significant (p>0.05). The prevalence of infarction showed significant correlation with the degree of steno-occlusive change in both the ICA and PCA. The degree of cerebral ischemia in moyamoya patients increased proportionally with the severity of PCA stenosis rather than with that of steno-occlusive lesins of the anterior circulation. Infarctions tended to be distributed in the anterior part of the hemisphere at PCA state I or II, while in more advanced PCA lesions, they were also found posteriorly, especially in the territories of the posterior middle cerebral artery

  4. High-Resolution CT and Angiographic Evaluation of NexStent Wall Adaptation

    International Nuclear Information System (INIS)

    Nemes, Balazs; Lukacs, Levente; Balazs, Gyoergy; Dosa, Edit; Berczi, Viktor; Huettl, Kalman

    2009-01-01

    Carotid stenting is a minimally invasive treatment for extracranial carotid artery stenosis. Stent design may affect technical success and complications in a certain subgroup of patients. We examined the wall adaptability of a new closed-cell carotid stent (NexStent), which has a unique rolled sheet design. Forty-one patients had 42 carotid arteries treated with angioplasty and stenting for internal carotid artery stenosis. The mean patient age was 65 ± 10 years. All patients underwent high-resolution computed tomographic angiography after the stent implantation. Data analysis included pre- and postprocedural stenosis, procedure complications, plaque calcification, and stent apposition. We reviewed the angiographic and computed tomographic images for plaque coverage and stent expansion. All procedures were technically successful. Mean stenosis was reduced from 84 ± 8% before the procedure to 15.7 ± 7% after stenting. Two patients experienced transient ischemic attack; one patient had bradycardia and hypotension. Stent induced kinking was observed in one case. Good plaque coverage and proper overlapping of the rolled sheet was achieved in all cases. There was weak correlation between the residual stenosis and the amount of calcification. The stent provides adequate expansion and adaptation to the tapering anatomy of the bifurcation.

  5. Determination of optimal angiographic viewing angles: Basic principles and evaluation study

    International Nuclear Information System (INIS)

    Dumay, A.C.M.; Reiber, J.H.C.; Gerbrands, J.J.

    1994-01-01

    Foreshortening of vessel segments in angiographic (biplane) projection images may cause misinterpretation of the extent and degree of coronary artery disease. The views in which the object of interest are visualized with minimum foreshortening are called optimal views. In this paper the authors present a complete approach to obtain such views with computer-assisted techniques. The object of interest is first visualized in two arbitrary views. Two landmarks of the object are manually defined in the two projection images. With complete information of the projection geometry, the vector representation of the object in the three-dimensional space is computed. This vector is perpendicular to a plane in which the views are called optimal. The user has one degree of freedom to define a set of optimal biplane views. The angle between the central beams of the imaging systems can be chosen freely. The computation of the orientation of the object and of corresponding optimal biplane views have been evaluated with a simple hardware phantom. The mean and the standard deviation of the overall errors in the calculation of the optimal angulation angles were 1.8 degree and 1.3 degree, respectively, when the user defined a rotation angle

  6. Local organ dose conversion coefficients for angiographic examinations of coronary arteries

    International Nuclear Information System (INIS)

    Schlattl, H; Zankl, M; Hausleiter, J; Hoeschen, C

    2007-01-01

    New organ dose conversion coefficients for coronary angiographic interventions are presented, as well as dose distributions and resulting maximal local dose conversion coefficients in the relevant organs. For the Monte Carlo based simulations, voxel models of the human anatomy were employed which represent the average Caucasian adult man and woman as defined by the International Commission on Radiological Protection. In the 21 investigated projections, the mean organ dose conversion coefficients vary from a few 0.01 to 2 mGy(Gy cm 2 ) -1 , depending on the projections. However, especially in portions of the lungs and the active bone marrow, the conversion coefficients can locally amount up to 10 mGy(Gy cm 2 ) -1 , which is half the average conversion coefficient of the skin at the field entrance. In addition to the dose conversion coefficients, the dependence of the patient dose on the projection has been estimated. It could be shown that the patient doses are highest for left anterior oblique views with strong caudal or cranial orientation. Nevertheless, for a large range of image-intensifier positions no significant dose differences could be found

  7. Radiation exposure to patient and radiologist during transcatheter arterial embolization therapy for hepatocellular carcinoma. Multicenter study in Japan

    International Nuclear Information System (INIS)

    Ishiguchi, T.; Nakamura, H.; Okazaki, M.

    2000-01-01

    Transcatheter arterial embolization (TAE) is now most commonly used as a treatment of hepatocellular carcinoma. Present multicenter study was carried out to evaluate radiation exposure to patients and interventional radiologists during the procedure. Thirty-nine procedures of TAE for hepatocellular carcinoma in eight institutes were analyzed. Radiation exposure to the patients and the interventional radiologists were evaluated with LiF thermoluminescence dosimeters (TLDs) placed on the patient's skin at the posterior hepatic portion and the pelvis and the operator's forehead and abdomen (in front and back of the lead apron). A real-time dosimeter was also used to evaluate skin dose of the patient. TAE was performed by angiographic techniques, using a microcatheter advanced to the hepatic artery branch(es) under the guidance of X-ray fluoroscopy and digital subtraction angiography (DSA), and then injecting chemotherapeutic agents mixed with oily contrast material and followed by gelatin sponge particles. The mean fluoroscopic time was 21 minutes and the mean number of DSA acquisition was 6. TLD dosimetry showed that the mean entrance surface dose of the patient at the hepatic portion was 973±681 mSv (mean±SD), and the anterior skin dose at the pelvis was 0.98±0.69 mSv. The doses of the radiologist were 0.04±0.04 mSv at the forehead, 0.15±0.19 mSv at the abdomen in front of the lead apron, and 0.005±0.01 mSv behind it. The real-time dosimetry showed that 56% of the surface dose at the hepatic portion was from DSA and 44% was from fluoroscopy. The radiation exposure to the patients and the interventional radiologists during TAE for hepatocellular carcinoma was considered to be acceptable when proper techniques are used. Further effort to reduce radiation doses during the procedure will be directed toward both digital angiographic and fluoroscopic techniques. (author)

  8. The Usefulness of Virtual Fluoroscopic Preprocedural Planning During Percutaneous Transhepatic Biliary Drainage

    Energy Technology Data Exchange (ETDEWEB)

    Kinoshita, Mitsuhiro, E-mail: kinoshita.3216@tokushima-u.ac.jp [Tokushima University Hospital, Department of Radiology (Diagnostic Radiology) (Japan); Shirono, Ryozo; Takechi, Katsuya [Tokushima Red Cross Hospital, Department of Radiology (Japan); Yonekura, Hironobu [Tokushima Red Cross Hospital, Department of Radiological Technology (Japan); Iwamoto, Seiji [Tokushima University Graduate School, Department of Radiology and Radiation Oncology, Institute of Biomedical Sciences (Japan); Shinya, Takayoshi [Tokushima University Hospital, Department of Radiology (Diagnostic Radiology) (Japan); Takao, Shoichiro [Tokushima University Graduate School of Health Science, Department of Diagnostic Radiology (Japan); Harada, Masafumi [Tokushima University Graduate School, Department of Radiology and Radiation Oncology, Institute of Biomedical Sciences (Japan)

    2017-06-15

    Purpose To retrospectively evaluate the usefulness of virtual fluoroscopic preprocedural planning (VFPP) in the percutaneous transhepatic biliary drainage (PTBD) procedure.Materials and MethodsTwenty-two patients who were treated by PTBD were included in this study. Twelve patients were treated using PTBD intraoperative referencing coronal computed tomography (CT) images (i.e., coronal CT group), and ten patients were treated using PTBD intraoperative referencing VFPP images (i.e., VFPP group). To analyze the effect of the intraoperative referencing VFPP image, the VFPP group was retrospectively compared with the coronal CT group.ResultsThe characteristics of both patient groups were not statistically significantly different. There were no significant differences in the targeted bile duct, diameter and depth of the target bile, breath-holding ability, number of targeted bile duct puncture attempts, change in the targeted bile duct, and exchange of the drainage catheter. However, the X-ray fluoroscopy time and the procedure time were significantly shorter in the VFPP group than in the coronal CT group (196 vs. 334 s, P < 0.05; and 16.0 vs. 27.2 min, P < 0.05).ConclusionIntraoperative referencing using the VFPP imaging in PTBD intuitively can be a useful tool for better localization of the guidewire in the bile duct and thereby shorten the X-ray fluoroscopy time and procedure time while minimizing radiation exposure and complications.

  9. Effects of intra-operative fluoroscopic 3D-imaging on peri-operative imaging strategy in calcaneal fracture surgery.

    Science.gov (United States)

    Beerekamp, M S H; Backes, M; Schep, N W L; Ubbink, D T; Luitse, J S; Schepers, T; Goslings, J C

    2017-12-01

    Previous studies demonstrated that intra-operative fluoroscopic 3D-imaging (3D-imaging) in calcaneal fracture surgery is promising to prevent revision surgery and save costs. However, these studies limited their focus to corrections performed after 3D-imaging, thereby neglecting corrections after intra-operative fluoroscopic 2D-imaging (2D-imaging). The aim of this study was to assess the effects of additional 3D-imaging on intra-operative corrections, peri-operative imaging used, and patient-relevant outcomes compared to 2D-imaging alone. In this before-after study, data of adult patients who underwent open reduction and internal fixation (ORIF) of a calcaneal fracture between 2000 and 2014 in our level-I Trauma center were collected. 3D-imaging (BV Pulsera with 3D-RX, Philips Healthcare, Best, The Netherlands) was available as of 2007 at the surgeons' discretion. Patient and fracture characteristics, peri-operative imaging, intra-operative corrections and patient-relevant outcomes were collected from the hospital databases. Patients in whom additional 3D-imaging was applied were compared to those undergoing 2D-imaging alone. A total of 231 patients were included of whom 107 (46%) were operated with the use of 3D-imaging. No significant differences were found in baseline characteristics. The median duration of surgery was significantly longer when using 3D-imaging (2:08 vs. 1:54 h; p = 0.002). Corrections after additional 3D-imaging were performed in 53% of the patients. However, significantly fewer corrections were made after 2D-imaging when 3D-imaging was available (Risk difference (RD) -15%; 95% Confidence interval (CI) -29 to -2). Peri-operative imaging, besides intra-operative 3D-imaging, and patient-relevant outcomes were similar between groups. Intra-operative 3D-imaging provides additional information resulting in additional corrections. Moreover, 3D-imaging probably changed the surgeons' attitude to rely more on 3D-imaging, hence a 15%-decrease of

  10. Contrast media for fluoroscopic examinations of the GI and GU tracts: current challenges and recommendations.

    Science.gov (United States)

    Federle, Michael P; Jaffe, Tracy A; Davis, Peter L; Al-Hawary, Mahmoud M; Levine, Marc S

    2017-01-01

    One of the significant challenges facing radiologists who perform and interpret studies of the gastrointestinal and genitourinary systems have been periodic interruptions in the availability of barium and iodinated contrast media specially formulated for gastrointestinal (GI) and genitourinary (GU) studies. These interruptions are due to the US Food and Drug Administration's recent requirement for more stringent documentation of the safety and efficacy of contrast media and the consolidation among contrast manufacturers. Therefore, radiologists may be required to recommend an alternative means of evaluation, such as computed tomography, magnetic resonance, or endoscopy, or they may need to substitute a different formulation of a contrast agent not specifically developed for GI or GU use, for example the utilization of an agent designed and marketed for vascular use. This article reviews the current status of fluoroscopic contrast media, and provides suggestions and recommendations for the optimal and alternative use of contrast media formulations.

  11. Relationship between source-surface distance and patient dose in fluoroscopic X-ray examinations

    International Nuclear Information System (INIS)

    Suzuki, Shoichi; Asada, Yasuki; Nishi, Kazuta; Mizuno, Emiko; Hara, Natsue; Orito, Takeo; Kamei, Tetsuya; Koga, Sukehiko

    2000-01-01

    The International Electrotechnical Commission, IEC provided in its standard IEC 60601-1-3 (1994) to prevent the use during radioscopic irradiation of focal spot to skin distances less than 20 cm if the X-RAY EQUIPMENT is specified for RADIOSCOPY during surgery or 30 cm for other specified applications. This standard was reflected in the Japanese Industrial Standard JIS Z 4701-1997, which provided the minimum distance from focal spot to skin to be 30 cm for the use of a fluoroscopic and radiographic table (Under-table type). However, JIS had formerly provided the minimum distance to be 40 cm and so does the current Medical Treatment Law. The draft revision for the Medical Treatment Law currently discussed has consideration to adopt the value 30 cm in accordance with the current JIS. Our research intended to investigate the impact on the entrance surface dose for the change of the focal spot to skin distance from 40 cm to 30 cm. The result was 20-30% increase of the entrance surface dose for the focal spot to skin distance 30 cm. Taking patient exposure dose into account, we need further and more sufficient discussion with this result before adopting this value to the Medical Treatment Law. (author)

  12. Fluoroscopic position of the second-generation cryoballoon during ablation in the right superior pulmonary vein as a predictor of phrenic nerve injury.

    Science.gov (United States)

    Saitoh, Yukio; Ströker, Erwin; Irfan, Ghazala; Mugnai, Giacomo; Ciconte, Giuseppe; Hünük, Burak; Velagić, Vedran; Overeinder, Ingrid; Tanaka, Kaoru; Brugada, Pedro; de Asmundis, Carlo; Chierchia, Gian-Battista

    2016-08-01

    Phrenic nerve injury (PNI) is the most frequently observed complication during pulmonary vein isolation procedure using the second-generation cryoballoon (CB). Our objective was to analyse the correlation between the fluoroscopic position of the 28 mm CB during ablation in the right superior pulmonary vein (RSPV) and the occurrence of PNI. A total of 165 patients having undergone the large 28 mm CB ablation were retrospectively reviewed. Positioning of the CB relative to the cardiac silhouette was classified under fluoroscopic guidance in antero-posterior projection during RSPV ablation. Regarding the lower half of the balloon, CB positioning was defined as follows: (A) completely inside the cardiac shadow; (B1) Phrenic nerve injury occurred in 9.7% (16/165) during ablation in the RSPV. The occurrence of PNI was 0.9, 10.6, and 90.1% in positions A, B1, and B2, respectively (A vs. B1, P = 0.01; B1 vs. B2, P < 0.0001). Among other pre-procedural and procedural variables, the B2 position was the strongest independent determinant for predicting PNI at RSPV (P = 0.001, odds ratio: 119.9; 95% confidence interval: 11.6-1234.7) after multivariable analysis. The incidence of PNI at the RSPV significantly increased in case of more distal positioning of the CB relative to the cardiac shadow. This simple and straightforward intra-procedural indicator might prone the operators to attempt occluding the RPSV more proximally in order to avoid PNI. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.

  13. Radiation dose and intra-articular access: comparison of the lateral mortise and anterior midline approaches to fluoroscopically guided tibiotalar joint injections

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Ambrose J.; Torriani, Martin; Bredella, Miriam A.; Chang, Connie Y.; Simeone, Frank J.; Palmer, William E. [Massachusetts General Hospital, Department of Radiology, Division of Musculoskeletal Imaging and Intervention, Boston, MA (United States); Balza, Rene [Centro Medico de Occidente, Department of Radiology, Maracaibo (Venezuela, Bolivarian Republic of)

    2016-03-15

    To compare the lateral mortise and anterior midline approaches to fluoroscopically guided tibiotalar joint injections with respect to successful intra-articular needle placement, fluoroscopy time, radiation dose, and dose area product (DAP). This retrospective study was IRB-approved and HIPAA-compliant. 498 fluoroscopically guided tibiotalar joint injections were performed or supervised by one of nine staff radiologists from 11/1/2010-12/31/2013. The injection approach was determined by operator preference. Images were reviewed on a PACS workstation to determine the injection approach (lateral mortise versus anterior midline) and to confirm intra-articular needle placement. Fluoroscopy time (minutes), radiation dose (mGy), and DAP (μGy-m{sup 2}) were recorded and compared using the student's t-test (fluoroscopy time) or the Wilcoxon rank sum test (radiation dose and DAP). There were 246 lateral mortise injections and 252 anterior midline injections. Two lateral mortise injections were excluded from further analysis because no contrast was administered. Intra-articular location of the needle tip was documented in 242/244 lateral mortise injections and 252/252 anterior midline injections. Mean fluoroscopy time was shorter for the lateral mortise group than the anterior midline group (0.7 ± 0.5 min versus 1.2 ± 0.8 min, P < 0.0001). Mean radiation dose and DAP were less for the lateral mortise group than the anterior midline group (2.1 ± 3.7 mGy versus 2.5 ± 3.5 mGy, P = 0.04; 11.5 ± 15.3 μGy-m{sup 2} versus 13.5 ± 17.3 μGy-m{sup 2}, P = 0.006). Both injection approaches resulted in nearly 100 % rates of intra-articular needle placement, but the lateral mortise approach used approximately 40 % less fluoroscopy time and delivered 15 % lower radiation dose and DAP to the patient. (orig.)

  14. Clinical and angiographic characteristics of young adult patients recovered from acute myocardial infarction

    Directory of Open Access Journals (Sweden)

    Miljković Dušan

    2015-01-01

    Full Text Available Introduction. Occurrence of acute myocardial infarction in young adults is a relatively rare. In majority of the studies, age of 45 years is used as cut-off line in definition of the young patients with coronary artery disease or myocardial infarction. Studies have shown that younger population aged less than 40 years represents only 2-8% of all patients with myocardial infarction. Objective. The aim of this study was to examine the specificities of clinical and angiographic characteristics of the patients recovered from acute myocardial infarction, younger than 45 years at the moment of attack, by comparing their clinical and angiographic characteristics with those of patients older than 65 years, who recovered from acute myocardial infarction. Method. The study included 78 patients recovered from acute myocardial infarction, 33 patients were younger than 45 years (40.7 ± 3.9 years, 25 (75.7% men and eight (24.2% female, and 45 patients were older than 65 years (68.2 ± 4.2 years, 32 (71.3% men and 13 women. Detailed history taking, physical examination, permanent ECG monitoring, laboratory analyses, X-ray examination, echocardiography and selective coronarography of all patients were performed. Results. Patients younger than 45 years had a significantly higher incidence of STEMI (p 0.05 Multivessel disease existed at 54.5% under the age of 45 and 77.8% older than 65 years (p0.05. The disease of left main coronary artery had 6.1% of patients younger than 45 and 22.2% of patients older than 65 years (p0.05 Were without significant coronary artery stenosis Comparing risk factors for coronary artery disease in patients younger than 45 years and older than 65 years, we find: hypertension in 48.5% vs. 88.9% (p0.05, diabetes mellitus in 21.2% vs. 55.5% (p 0.05, and stress in 18.2% vs. 2.2% (p <0.01. Conclusion. Patients with myocardial infarction younger than 45 years are predominantly male and have a significantly higher incidence of infarction

  15. Idiopathic polypoidal choroidal vasculopathy in Thai patients with clinical and angiographic choroidal neovascularization

    Directory of Open Access Journals (Sweden)

    Bhoomibunchoo C

    2017-02-01

    Full Text Available Chavakij Bhoomibunchoo,1 Yosanan Yospaiboon,1 Somanus Thoongsuwan,2 Duangnate Rojanaporn,3 Nawat Watanachai,4 Pichai Jirarattanasopa,5 Nattapon Wongcumchang,6 Atchara Amphornphruet,7 Sritatath Vongkulsiri,8 Eakkachai Arayangkoon9 1Department of Ophthalmology, Faculty of Medicine, Khon Kaen University, Khon Kaen, 2Department of Ophthalmology, Faculty of Medicine, Siriraj Hospital, Mahidol University, Bangkok, 3Department of Ophthalmology, Faculty of Medicine, Ramathibodi Hospital, Mahidol University, Bangkok, 4Department of Ophthalmology, Faculty of Medicine, Chiang Mai University, Chiang Mai, 5Department of Ophthalmology, Faculty of Medicine, Prince of Songkla University, Songkhla, 6Department of Ophthalmology, Faculty of Medicine, Thammasat University, Pathum Thani, 7Department of Ophthalmology, Rajavithi Hospital, Bangkok, 8Department of Ophthalmology, Phramongkutklao Hospital, Bangkok, 9Department of Ophthalmology, Mettapracharak Hospital, Nakhon Pathom, Thailand Objective: This study aimed to study the prevalence and characteristics of idiopathic polypoidal choroidal vasculopathy (IPCV in Thai patients with clinical and angiographic choroidal neovascularization (CNV.Patients and methods: A consecutive case study of 140 patients presenting with CNV was conducted in nine large referral eye centers throughout Thailand. The demographic data, fundus photographs, fundus fluorescein angiography and indocyanine green angiography of the patients were analyzed.Results: Of 129 patients with clinical and angiographic CNV, IPCV was diagnosed in 100 patients (77.52%, idiopathic CNVs in 16 patients (12.40% and age-related macular degeneration (AMD in 12 patients (9.30%. Of the 107 eyes with IPCV, 90 eyes (84.11% had both branching venous networks (BVNs and polypoidal lesions. Most IPCV patients (93% had unilateral involvement and were at a younger age than AMD patients. In all, 79 eyes (73.83% had lesions found in the macular area, 14 eyes (13.08% in the

  16. The angiographic findings and interventional treatment of the iatrogenic hemobilia

    International Nuclear Information System (INIS)

    Wen feng; Lu Zaiming; Sun Wei; Li Wei; Guo Qiyong

    2012-01-01

    Objective: To evaluate the angiography and interventional embolization in diagnosing and treating the iatrogenic hemobilia. Methods: A total of 21 patients with iatrogenic hemobilia were enrolled in this study. The clinical data were retrospectively analyzed. Percutaneous selective superior mesenteric artery angiography, celiac angiography and common hepatic artery angiography were carried out in all patients. After the bleeding sites were clarified, selective or super-selective catheterization and embolization were performed. The clinical results were analyzed. Results: Active bleeding was confirmed by angiography in all the 21 cases. Angiographic findings included pseudoaneurysm (n=17, 81.0%) and extravasation of contrast medium (n=4, 19.0%). The embolic agents used in this study included polyvinyl alcohol particles (n=2), pure coils (n=8) or Gelfoam particles plus coils (n=11). The success rate of hemostasis after single embolization was 85.7% (18/21), and second embolization procedure had to be carried out in three patients as recurrent massive bleeding occurred in them. All the patients were followed up for 5 to 28 months, and no recurrent hemobilia was observed. No serious complications such as non-targeted vessel embolization, liver function failure, embolization-related infection, etc. occurred. Conclusion: For the treatment of iatrogenic hemobilia, percutaneous selective angiography together with interventional embolization is safe, minimally-invasive, reliable and effective, and this technique should be regarded as the treatment of first choice. (authors)

  17. Micro-turbines

    International Nuclear Information System (INIS)

    Tashevski, Done

    2003-01-01

    In this paper a principle of micro-turbines operation, type of micro-turbines and their characteristics is presented. It is shown their usage in cogeneration and three generation application with the characteristics, the influence of more factors on micro-turbines operation as well as the possibility for application in Macedonia. The paper is result of the author's participation in the training program 'Micro-turbine technology' in Florida, USA. The characteristics of different types micro-turbines by several world producers are shown, with accent on US micro-turbines producers (Capstone, Elliott). By using the gathered Author's knowledge, contacts and the previous knowledge, conclusions and recommendations for implementation of micro-turbines in Macedonia are given. (Author)

  18. Micro rapid prototyping system for micro components

    International Nuclear Information System (INIS)

    Li Xiaochun; Choi Hongseok; Yang Yong

    2002-01-01

    Similarities between silicon-based micro-electro-mechanical systems (MEMS) and Shape Deposition Manufacturing (SDM) processes are obvious: both integrate additive and subtractive processes and use part and sacrificial materials to obtain functional structures. These MEMS techniques are two-dimensional (2-D) processes for a limited number of materials while SDM enables the building of parts that have traditionally been impossible to fabricate because of their complex shapes or of their variety in materials. This work presents initial results on the development of a micro rapid prototyping system that adapts SDM methodology to micro-fabrication. This system is designed to incorporate microdeposition and laser micromachining. In the hope of obtaining a precise microdeposition, an ultrasonic-based micro powder-feeding mechanism was developed in order to form thin patterns of dry powders that can be cladded or sintered onto a substrate by a micro-sized laser beam. Furthermore, experimental results on laser micromachining using a laser beam with a wavelength of 355 nm are also presented. After further improvement, the developed micro manufacturing system could take computer-aided design (CAD) output to reproduce 3-D heterogeneous micro-components from a wide selection of materials

  19. The anterior choroidal artery syndrome. Pt. 2. CT and/or MR in angiographically verified cases

    International Nuclear Information System (INIS)

    Takahashi, S.; Ishii, K.; Matsumoto, K.; Higano, S.; Ishibashi, T.; Suzuki, M.; Sakamoto, K.

    1994-01-01

    We reviewed 12 cases of infarcts in the territory of the anterior choroidal artery (AChA) on CT and/or MRI. In each case vascular occlusion in the region was verified angiographically. Although the extent of the lesion on CT/MR images was variable, all were located on the axial images within an arcuate zone between the striatium anterolaterally and the thalamus posteromedially. The distribution of the lesions on mutiplanar MRI conformed well to the territory of the AChA demonstrated microangiographically. The variability of the extent of the infarcts may be explained by variations in the degree of occlusive changes in the AChA or the development of collateral circulation through anastomoses between the AChA and the posterior communicating and posterior cerebral arteries. The extent of the lesion appeared to be closely related to the degree of neurological deficit. (orig.)

  20. Laser beam micro-milling of micro-channels in aerospace alloys

    CERN Document Server

    Ahmed, Naveed; Al-Ahmari, Abdulrahman

    2017-01-01

    This volume is greatly helpful to micro-machining and laser engineers as it offers obliging guidelines about the micro-channel fabrications through Nd:YAG laser beam micro-milling. The book also demonstrates how the laser beam micro-milling behaves when operating under wet conditions (under water), and explores what are the pros and cons of this hybrid technique. From the predictive mathematical models, the readers can easily estimate the resulting micro-channel size against the desired laser parametric combinations. The book considers micro-channels in three highly important research materials commonly used in aerospace industry: titanium alloy Ti-6Al-4V, nickel alloy Inconel 718 and aluminum alloy AA 2024. Therefore, the book is highly practicable in the fields of micro-channel heat exchangers, micro-channel aerospace turbine blades, micro-channel heat pipes, micro-coolers and micro-channel pulsating heat plates. These are frequently used in various industries such as aerospace, automotive, biomedical and m...

  1. The prevalence and clinical profile of angiographic coronary ectasia

    International Nuclear Information System (INIS)

    Sultana, R.; Ishaq, M.; Samad, A.

    2011-01-01

    To determine the incidence of Coronary Artery Ectasia (CAE) at our teaching hospital to describe the patients and angiographic characteristics. Methods: A retrospective analysis was conducted on all coronary angiograms performed at the catheterization laboratory of Karachi Institute of Heart Diseases, a tertiary care center, between the period of August 2006 and August 2008. A one year follow up was performed to look for primary and secondary endpoints. Data were collected from catheterization films, and medical records. Results: Five thousand coronary angiograms were performed during the period of of the study. A total of 140 (2.8%) angiograms showed coronary ectasia of both mixed and pure types. Pure ectasia with no coronary obstructive lesions was seen in 75 (1.5%). The left anterior descending artery (LAD) was the most commonly affected vessel (63%) followed by the right coronary artery (RCA) 25% and 10% patients had circumflex artery involvement. The primary composite endpoint showed 6 (4.2%) patients with non-ST elevation MI, 5 (3.6%) with ST elevation inferior wall myocardial infarction, 70 (50%) with unstable angina and 2 (1.4%) deaths due to pulmonary oedema. Secondary endpoints showed 50% of the patients still complaining of chest pain. Conclusion: Prevalence of Coronary ectasia in the population presenting to KIHD during the study period was 1.5%. Majority of patients were males, associated with dyslipidaemia, hypertension and smoking. CAE was associated with obstructive coronary artery disease in about 80% of cases. LAD was the most commonly affected vessel. (author)

  2. Ovarian Artery: Angiographic Appearance, Embolization and Relevance to Uterine Fibroid Embolization

    International Nuclear Information System (INIS)

    Pelage, J.P.; Walker, W.J.; Le Dref, O.; Rymer, R.

    2003-01-01

    Purpose: To describe the angiographic appearance of the ovarian artery and its main variations that may be relevant to uterine fibroid embolization. Methods: The flush aortograms of 294 women who had been treated by uterine artery embolization for fibroids were reviewed. Significant arterial supply to the fibroid, and the origin and diameter of identified ovarian arteries were recorded. In patients with additional embolization of the ovarian artery, the follow-up evaluation also included hormonal levels and Doppler imaging of the ovaries. Results: A total of 75 ovarian arteries were identified in 59 women (bilaterally in 16 women and unilaterally in 43 women). All ovarian arteries originated from the aorta below the level of the renal arteries with a characteristic tortuous course. Fifteen women had at least one enlarged ovarian artery supplying the fibroids. Fourteen women (14/15, 93%) presented at least one of the following factors: prior pelvic surgery, tubo-ovarian pathology or large fundal fibroids. Conclusion: We advocate the use of flush aortography in women with prior tubo-ovarian pathology or surgery or in cases of large fundal fibroids. In the case of an ovarian artery supply to the fibroids, superselective catheterization and embolization of the ovarian artery should be considered

  3. [Myocardial infarction related to sport. Acute clinical and coronary angiographic characteristics in 16 cases].

    Science.gov (United States)

    Halna du Fretay, X; Akoudad, H; Nejjari, M; Benamer, H

    2013-12-01

    Determination of clinical and angiographic characteristics of myocardial infarctions related to sport. Retrospective study of acute coronary syndromes with ST elevation related to sport treated with interventional cardiology from 2006 to 2013. Sixteen patients were included. They are mostly men (15/16), aged 24-65 years (over 35 years old in 13 cases) with few cardiovascular risk factors, most frequently heredity or smoking. Myocardial infarctions usually occur during the practice of sports (13/16), with serious rhythmic complications in three of the cases. On angiography, most patients have single vessel disease (12/16). Myocardial infarction related to sports affects a male population aged over 35 years old with few cardiovascular risk factors, most often single vessel disease, making the preventative screening uneasy. Other studies investigating larger populations, assessing previous clinical events (symptoms, results of stress tests), evaluating the impact of competition and integrating sudden deaths would improve the screening and the treatment of sport-related myocardial infarctions. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  4. Gastroesophageal Variceal Filling and Drainage Pathways: An Angiographic Description of Afferent and Efferent Venous Anatomic Patterns

    Directory of Open Access Journals (Sweden)

    Ron C Gaba

    2015-01-01

    Full Text Available Varices commonly occur in liver cirrhosis patients and are classified as esophageal (EV, gastroesophageal (GEV, or isolated gastric (IGV varices. These vessels may be supplied and drained by several different afferent and efferent pathways. A working knowledge of variceal anatomy is imperative for Interventional Radiologists performing transjugular intrahepatic portosystemic shunt and embolization/obliteration procedures. This pictorial essay characterizes the angiographic anatomy of varices in terms of type and frequency of venous filling and drainage, showing that different varices have distinct vascular anatomy. EVs typically show left gastric vein filling and “uphill” drainage, and GEVs and IGVs exhibit additional posterior/short gastric vein contribution and “downhill” outflow. An understanding of these variceal filling and drainage pathways can facilitate successful portal decompression and embolization/obliteration procedures.

  5. A thermally self-sustained micro-power plant with integrated micro-solid oxide fuel cells, micro-reformer and functional micro-fluidic carrier

    Science.gov (United States)

    Scherrer, Barbara; Evans, Anna; Santis-Alvarez, Alejandro J.; Jiang, Bo; Martynczuk, Julia; Galinski, Henning; Nabavi, Majid; Prestat, Michel; Tölke, René; Bieberle-Hütter, Anja; Poulikakos, Dimos; Muralt, Paul; Niedermann, Philippe; Dommann, Alex; Maeder, Thomas; Heeb, Peter; Straessle, Valentin; Muller, Claude; Gauckler, Ludwig J.

    2014-07-01

    Low temperature micro-solid oxide fuel cell (micro-SOFC) systems are an attractive alternative power source for small-size portable electronic devices due to their high energy efficiency and density. Here, we report on a thermally self-sustainable reformer-micro-SOFC assembly. The device consists of a micro-reformer bonded to a silicon chip containing 30 micro-SOFC membranes and a functional glass carrier with gas channels and screen-printed heaters for start-up. Thermal independence of the device from the externally powered heater is achieved by exothermic reforming reactions above 470 °C. The reforming reaction and the fuel gas flow rate of the n-butane/air gas mixture controls the operation temperature and gas composition on the micro-SOFC membrane. In the temperature range between 505 °C and 570 °C, the gas composition after the micro-reformer consists of 12 vol.% to 28 vol.% H2. An open-circuit voltage of 1.0 V and maximum power density of 47 mW cm-2 at 565 °C is achieved with the on-chip produced hydrogen at the micro-SOFC membranes.

  6. Angiographically occult vascular malformation of the brain: MR imaging at 1.5 T

    International Nuclear Information System (INIS)

    Patel, S.C.; Sanders, W.P.; Fuentes, J.; Haggar, A.M.; Mehta, B.A.; Boulos, R.S.; Froelich, J.W.

    1986-01-01

    MR imaging was performed in nine patients with 12 angiographically occult arteriovenous malformations using a 1.5-T superconducting magnet; four additional patients were imaged using a 0.3-T system. All images were reviewed in conjunction with CT scans. The following observations were made. (1) Eleven of 14 supratentorial lesions were located at the junction of gray and white matter. (2) Exclusing acute hemorrhage, only two lesions displayed mild mass effect. (3) All lesions displayed central foci of high signal intensity, probably representing subacute hemorrhage. (4) All lesions but one showed a peripheral rim of low signal intensity which progressively lost signal with increasing T2 weighting. This most likely represents iron-containing hemosiderin deposition. (5) Lesions were best demonstrated with long repetition times and moderate T2 weighting (TR = 2,500 msec, TE = 25-100 msec). (6) All lesions but one were hyperdense on non-contrast-enhanced CT, although only three had unequivocal calcification. The possibility of hyperdensity due to blood or iron deposition is discussed

  7. Patient and staff doses and relationships between them in fluoroscopically guided procedures

    International Nuclear Information System (INIS)

    Avramova-Cholakova, S.; Christova-Popova, Y.; Sagorska, A.

    2015-01-01

    Full text: Medical exposure has the main contribution to man-made sources of exposures to the population in developed countries. Fluoroscopically guided procedures in interventional cardiology, gastroenterology, urology, orthopaedics and others may be related to high doses to both patients and staff. The main risk for both groups is the radiation carcinogenesis and it is increasing with dose. However deterministic effects are also possible: severe patient skin injuries occur sometimes. There are such cases in Bulgarian radiological practice. For the medical staff, involved in the procedures, radiation induced cataract is observed occasionally. Learning objective: In many cases there is direct correlation between patient and staff doses. Several simple rules must be observed in order to decrease exposure. Rules related to patient: Patient dose (dose-area product (DAP), fluoroscopy time, number of series,number of images) should be recorded for every patient; The patient should be positioned as far away as possible from the x-ray tube and as closer as possible to the image intensifier/digital image receptor; Fluoroscopy time should be minimized; Pulsed fluoroscopy with the lowest dose rate and the lowest frame rate providing acceptable image quality should be used; Different skin areas should be exposed in different projections; Oblique projections increase the dose - they should be avoided; Magnification also increases the dose several times and should be avoided; The acquisition mode should be avoided; it delivers dozens of times higher doses. Minimal number of frames and cine runs should be used. Use of “last image hold” is encouraged; The x-ray beam should be collimated to the area of interest. Rules related to staff: The staff receives scattered radiation from patient’s body. Every measure to decrease patient’s dose decreases staff dose as well; Every available protective device should be used (lead apron, thyroid collar, lead glasses, screens). They

  8. The relation between ankle-brachial index (ABI and coronary artery disease severity and risk factors: an angiographic study

    Directory of Open Access Journals (Sweden)

    Masoumeh Sadeghi

    2011-07-01

    Full Text Available BACKGROUND: The current study aims to determine the relation between ankle–brachialindex (ABI and angiographic findings and major cardiovascular risk factors in patients withsuspected coronary artery diseases (CAD in Isfahan.METHODS: In this cross-sectional descriptive-analytic research, patients with suspected CADwere studied. Characteristics of studied subjects including demographics, familial history, pastmedical history and atherosclerotic risk factors such as diabetes mellitus, hypertension,hyperlipidemia and smoking were obtained using a standard questionnaire. ABI was measuredin all studied patients. ABI ≤ 0.9 (ABI+ was considered as peripheral vessel disease and ABI >0.9 (ABI- was considered as normal. Then, all studied patients underwent coronary arteryangiography. The results of the questionnaire and angiographic findings were compared in ABI+and ABI- groups. Data were analyzed by SPSS 15 using ANOVA, t-test, Spearman's rankcorrelation coefficient, and discriminant analysis.RESULTS: In this study, 125 patients were investigated. ABI ≤ 0.9 was seen in 25 patients (20%.The prevalence of ABI+ among men and women was 25.9% and 7.5%, respectively (P = 0.01. Theprevalence of atherosclerotic risk factors was significantly higher in ABI+ patients than in ABIones(P < 0.05. ABI+ patients had more significant stenosis than ABI- ones. The mean ofocclusion was significantly higher in ABI+ patients with left main artery (LMA, right coronaryartery (RCA, left anterior descending artery (LAD, diagonal artery 1 (D1 and left circumflexartery (LCX involvements (P < 0.05.CONCLUSION: The findings of this research indicated that ABI could be a useful method inassessing both the atherosclerotic risk factors and the degree of coronary involvements insuspected patients. However, in order to make more accurate decisions for using this method indiagnosing and preventing CAD, we should plan further studies in large sample sizes of generalpopulation

  9. Angiographic follow-up after carotid artery stenting of bifurcation stenosis; Angiographische Verlaufskontrolle nach Stentimplantation zur Behandlung der Karotisbifurkationsstenose

    Energy Technology Data Exchange (ETDEWEB)

    Hauth, E.A.; Forsting, M. [Inst. fuer Diagnostische und Interventionelle Radiologie und Neuroradiologie, Universitaetsklinik Essen (Germany); Jansen, C.; Drescher, R.; Mathias, K. [Radiologische Klinik, Klinikum Dortmund (Germany); Schwarz, M. [Neurologische Klinik, Klinikum Dortmund (Germany); Christmann, A. [Fachbereich Statistik, Univ. Dortmund (Germany); Jaeger, H. [Radiologische Klinik, Klinikum Dortmund (Germany); Marien-Hospital Wesel, Praxis fuer Radiologie, Neuroradiologie and Nuklearmedizin (Germany)

    2006-08-15

    Purpose: the purpose of this prospective study was to determine the restenosis grade, the intima hyperplasia and the stent expansion via angiographic follow-up six months after carotid artery stenting. Materials and methods: in 100 patients, angiographic follow-up was performed 5.9 months (range: 2.9 - 11.4 months) after carotid artery stenting. The restenosis grade, the intima hyperplasia and the stent expansion were measured by selective angiography of the treated carotid artery. Results: the mean restenosis grade was 16% (range: 0 - 78%). In 6 of 100 patients (6%), a restenosis grade of > 50% was measured. In 4 patients the restenosis grade was 50 - 70%. In 2 patients the restenosis grade was > 70%. In 91 of 100 patients (91%), the restenosis was localized in the former area of stenosis of the carotid artery, and in 9 of 100 patients (9%), the restenosis was localized in the cranial stent end. The mean grade of intima hyperplasia was 31% (range: 2 - 70%). The mean increase in stent expansion at the time of follow-up was 10% (range: 0 - 59%). No correlation was able to be determined between the grade of stenosis and the grade of restenosis (rho = 0,017, range: -0.180 - 0.213), between the grade of residual stenosis and the grade of restenosis (rho = 0,257, range: 0.064 - 0.431) and between intima hyperplasia and the grade of restenosis (rho = 0,476, range: 0.309 - 0.615). Conclusions: carotid artery stenting is associated with a low incidence of high-grade restenosis 6 months after an intervention. The intima hyperplasia, which can be observed in each Wallstent, is partly compensated by the expansion of the self-expandable stent. Without a correlation between the grade of residual stenosis and the grade of restenosis, low-grade residual stenosis can be accepted. Therefore, we recommend undersized postdilation of the Wallstent. (orig.)

  10. A novel method for the angiographic estimation of the percentage of spleen volume embolized during partial splenic embolization

    International Nuclear Information System (INIS)

    Ou, Ming-Ching; Chuang, Ming-Tsung; Lin, Xi-Zhang; Tsai, Hong-Ming; Chen, Shu-Yuan; Liu, Yi-Sheng

    2013-01-01

    Purpose: To evaluate the efficacy of estimating the volume of spleen embolized in partial splenic embolization (PSE) by measuring the diameters of the splenic artery and its branches. Materials and methods: A total of 43 liver cirrhosis patients (mean age, 62.19 ± 9.65 years) with thrombocytopenia were included. Among these, 24 patients underwent a follow-up CT scan which showed a correlation between angiographic estimation and measured embolized splenic volume. Estimated splenic embolization volume was calculated by a method based on diameters of the splenic artery and its branches. The diameters of each of the splenic arteries and branches were measured via 2D angiographic images. Embolization was performed with gelatin sponges. Patients underwent follow-up with serial measurement of blood counts and liver function tests. The actual volume of embolized spleen was determined by computed tomography (CT) measuring the volumes of embolized and non-embolized spleen two months after PSE. Results: PSE was performed without immediate major complications. The mean WBC count significantly increased from 3.81 ± 1.69 × 10 3 /mm 3 before PSE to 8.56 ± 3.14 × 10 3 /mm 3 at 1 week after PSE (P < 0.001). Mean platelet count significantly increased from 62.00 ± 22.62 × 10 3 /mm 3 before PSE to 95.40 ± 46.29 × 10 3 /mm 3 1 week after PSE (P < 0.001). The measured embolization ratio was positively correlated with estimated embolization ratio (Spearman's rho [ρ] = 0.687, P < 0.001). The mean difference between the actual embolization ratio and the estimated embolization ratio was 16.16 ± 8.96%. Conclusions: The method provides a simple method to quantitatively estimate embolized splenic volume with a correlation of measured embolization ratio to estimated embolization ratio of Spearman's ρ = 0.687

  11. Pulmonary arteriography by digital subtraction angiographic method in cyanotic heart disease with pulmonary stenosis or pulmonary atresia

    International Nuclear Information System (INIS)

    Kobayashi, Junjiro; Hirose, Hajime; Nakano, Susumu

    1985-01-01

    Pulmonary arteriography was performed by digital subtraction angiographic (DSA) method in 10 patients with cyanotic heart disease associated with pulmonary stenosis or pulmonary atresia. Ten patients consisted of five patients with tetralogy of Fallot, three with single ventricle and pulmonary stenosis, and two with pseudotruncus arteriosus. Hepato-clavicular position was taken in four patients. Pulmonary artery and its main branches were opacified and recognized clearly, and their diameter could be measured accurately with a small amount of contrast medium. There was a good correlation between the diameter of pulmonary artery measured by DSA and that measured by conventional pulmonary arteriography. DSA is a useful method for evaluating the size and the stenosis of pulmonary artery especially in small cyanotic infants. (author)

  12. Palliation of malignant gastric obstruction : fluoroscopic guided covered metallic stent placement

    International Nuclear Information System (INIS)

    Lee, Jeong Min; Han, Young Min; Kim, Chong Soo; Lee, Sang Yong; Choi, Ki Chul; Lee, Soo Tak; Han, Hyun Young

    2000-01-01

    To demonstrate the feasibility and clinical efficacy of self-expanding, covered metallic stent placement for the palliative treatment of malignant gastric obstruction. Under fluoroscopic guidance, the placement of self-expanding, covered stents was attempted in 23 patients (age range, 31-78 years) with inoperable or recurrent gastric malignancies. All 23 suffered dysphagia and/or vomiting after the ingestion of soft foods, or swallowing difficulty. Three different types of self-expanding, covered metallic stents were used and in all patients, these were placed perorally using over the guide wire technique. Success was defined both technically and clinically. Stent placement was technically successful in 19 patients (82.6%) but because the guidewire failed to successfully negotiate the sites at which there was obstruction, was unsuccessful in four (17.4%). Stent placement was well tolerated in all patients except one, in whom an acutely angled efferent loop from remnant stomach was present. In this case, stent placement required a strong metallic guidewire. After placement, 17 of the 19 patients (89.5%) were able to ingest solid and/or soft foods without dysphagia and showed a markedly decreased incidence of vomiting. Two others showed some improvement in the frequency of vomiting but were able to ingest only a liquid diet. In one patient, the stent migrated two days after the procedure. During the follow-up period of 2-7 months (mean, 74 days), there were no clinically significant complications. For the short-term palliative treatment of patients with gastric inlet or outlet obstruction, the placement of self-expanding metallic stents has proven relatively easy and safe, as well as reasonably effective. (author)

  13. Quantification of myocardium at risk in ST- elevation myocardial infarction: a comparison of contrast-enhanced steady-state free precession cine cardiovascular magnetic resonance with coronary angiographic jeopardy scores.

    Science.gov (United States)

    De Palma, Rodney; Sörensson, Peder; Verouhis, Dinos; Pernow, John; Saleh, Nawzad

    2017-07-27

    Clinical outcome following acute myocardial infarction is predicted by final infarct size evaluated in relation to left ventricular myocardium at risk (MaR). Contrast-enhanced steady-state free precession (CE-SSFP) cardiovascular magnetic resonance imaging (CMR) is not widely used for assessing MaR. Evidence of its utility compared to traditional assessment methods and as a surrogate for clinical outcome is needed. Retrospective analysis within a study evaluating post-conditioning during ST elevation myocardial infarction (STEMI) treated with coronary intervention (n = 78). CE-SSFP post-infarction was compared with angiographic jeopardy methods. Differences and variability between CMR and angiographic methods using Bland-Altman analyses were evaluated. Clinical outcomes were compared to MaR and extent of infarction. MaR showed correlation between CE-SSFP, and both BARI and APPROACH scores of 0.83 (p < 0.0001) and 0.84 (p < 0.0001) respectively. Bias between CE-SSFP and BARI was 1.1% (agreement limits -11.4 to +9.1). Bias between CE-SSFP and APPROACH was 1.2% (agreement limits -13 to +10.5). Inter-observer variability for the BARI score was 0.56 ± 2.9; 0.42 ± 2.1 for the APPROACH score; -1.4 ± 3.1% for CE-SSFP. Intra-observer variability was 0.15 ± 1.85 for the BARI score; for the APPROACH score 0.19 ± 1.6; and for CE-SSFP -0.58 ± 2.9%. Quantification of MaR with CE-SSFP imaging following STEMI shows high correlation and low bias compared with angiographic scoring and supports its use as a reliable and practical method to determine myocardial salvage in this patient population. Clinical trial registration information for the parent clinical trial: Karolinska Clinical Trial Registration (2008) Unique identifier: CT20080014. Registered 04 th January 2008.

  14. Thermal performance of a micro-combustor for micro-gas turbine system

    International Nuclear Information System (INIS)

    Cao, H.L.; Xu, J.L.

    2007-01-01

    Premixed combustion of hydrogen gas and air was performed in a stainless steel based micro-annular combustor for a micro-gas turbine system. Micro-scale combustion has proved to be stable in the micro-combustor with a gap of 2 mm. The operating range of the micro-combustor was measured, and the maximum excess air ratio is up to 4.5. The distribution of the outer wall temperature and the temperature of exhaust gas of the micro-combustor with excess air ratio were obtained, and the wall temperature of the micro-combustor reaches its maximum value at the excess air ratio of 0.9 instead of 1 (stoichiometric ratio). The heat loss of the micro-combustor to the environment was calculated and even exceeds 70% of the total thermal power computed from the consumed hydrogen mass flow rate. Moreover, radiant heat transfer covers a large fraction of the total heat loss. Measures used to reduce the heat loss were proposed to improve the thermal performance of the micro-combustor. The optimal operating status of the micro-combustor and micro-gas turbine is analyzed and proposed by analyzing the relationship of the temperature of the exhaust gas of the micro-combustor with thermal power and excess air ratio. The investigation of the thermal performance of the micro-combustor is helpful to design an improved micro-combustor

  15. Factors and strategies in the occupational monitoring of personnel in medical angiography

    International Nuclear Information System (INIS)

    Benedict, S.H.; Kleck, J.H.; McLaughlin, J.E.

    1988-01-01

    Angiographic procedures which include extensive fluoroscopy are among those which can produce the highest radiation exposure of hospital workers. The introduction of hemiaxial projections, and vascular fluoroscopic boost imaging methods has increased diagnostic accuracy, but it has also increased the physician's exposure to scattered radiation. Medical facilities in angiography and catheterization vary in regards to type of equipment and training of personnel. The health physicist for a facility is compelled to initiate a program to measure the potential exposure from a facility as well as assist in the training of personnel to minimize the exposure. Training of the medical personnel also includes techniques of exposure monitoring which for some individuals is more practically attained by utilization of a double badge program. This is especially important in the university setting where new residents and fellows are being introduced to the facility

  16. The optimal project position for demonstrating tricuspid annulus in angiography: an experimental study

    International Nuclear Information System (INIS)

    Bai Yuan; Zong Gongjun; Wang Hongru; Qin Yongwen; Huang Xinmiao; Jiang Haibin

    2009-01-01

    Objective: To explore the optimal project position for demonstrating tricuspid annulus angiographically in experimental goats. Methods: Eight healthy goats underwent right atrial angiography by using 6 F pig tail catheters. Under fluoroscopic monitoring the contrast media (total 110 ml, flow rate 12 ml/ s, pressure 800 psi) was injected continuously while a serious exposures were performed from RAO position to LAO position (totally 180 degree rotation). The maximum diameter of the tricuspid annulus in every picture was measured and the results were compared with that obtained from sonography. Results: The procedure was successful in all 8 experimental goats. The optimal project position to display the tricuspid annulus was at 27 degree ± 3 degree in RAO position. Conclusion: In angiography, the tricuspid annulus can be best demonstrated at the project position of 27 degree ± 3 degree in RAO. (authors)

  17. Isolation of microRNA targets using biotinylated synthetic microRNAs

    DEFF Research Database (Denmark)

    Ørom, Ulf Andersson; Lund, Anders H

    2007-01-01

    MicroRNAs are small regulatory RNAs found in multicellular organisms where they post-transcriptionally regulate gene expression. In animals, microRNAs bind mRNAs via incomplete base pairings making the identification of microRNA targets inherently difficult. Here, we present a detailed method...... for experimental identification of microRNA targets based on affinity purification of tagged microRNAs associated with their targets. Udgivelsesdato: 2007-Oct...

  18. WE-E-18A-09: Application of a Channelized Hotelling Observer Model to Evaluate Angiographic Imaging Equipment

    Energy Technology Data Exchange (ETDEWEB)

    Favazza, C; Fetterly, K; Hangiandreou, N; Leng, S; Schueler, B [Mayo Clinic, Rochester, MN (United States)

    2014-06-15

    Purpose: To develop and apply an observer model to objectively evaluate and compare the performance of different angiographic imaging equipment and acquisition variables. Methods: Image Acquisition— Iodine-based phantoms were created with target diameters: 0.5, 1, 2, and 4 mm. The phantoms were imaged using both planes of a bi-plane angiography system with detector pixel dimensions 0.1542 mm{sup 2} and 0.1842 mm{sup 2}, respectively. All four phantoms were imaged with magnification factors 1.5, 1.25 and 1 and with the large and small focal spots. Phantom position and the dose per frame (0.12– 0.24 μ Gy/frame) were varied for a single phantom size, magnification and focal spot. Observer Model— For each experimental condition, 1200 signal-present and signal-absent images were acquired and a detectability index (d') was calculated with a Gabor-channelized Hotelling observer (CHO) model. Detectability indices were evaluated as a function of dose, phantom size, and magnification. The model was then applied to compare d' of the two imaging planes and focal spots. Uncertainty in d' was estimated by bootstrapping the data and by examining the shift-variance of systems. Results: Detectability indices varied linearly with magnification and the square root of dose. For the 2 and 4 mm phantoms, d' varied linearly with diameter. For the 0.5 and 1 mm phantoms, d' expectedly deviated from this linear relationship due to substantial detector and focal spot blurring of the phantoms. The small focal spot yielded up to 50% greater d' values than the large focal spot. For the two detectors, differences in d' did not exceed the estimated ∼7% error. Conclusions: The detectability indices predictably scaled with dose, diameter, magnification, and focal spot size and serve to validate the model. Results demonstrate statistically similar target detectability for both investigated detectors, despite differences in pixel dimensions. This CHO model

  19. WE-E-18A-09: Application of a Channelized Hotelling Observer Model to Evaluate Angiographic Imaging Equipment

    International Nuclear Information System (INIS)

    Favazza, C; Fetterly, K; Hangiandreou, N; Leng, S; Schueler, B

    2014-01-01

    Purpose: To develop and apply an observer model to objectively evaluate and compare the performance of different angiographic imaging equipment and acquisition variables. Methods: Image Acquisition— Iodine-based phantoms were created with target diameters: 0.5, 1, 2, and 4 mm. The phantoms were imaged using both planes of a bi-plane angiography system with detector pixel dimensions 0.1542 mm 2 and 0.1842 mm 2 , respectively. All four phantoms were imaged with magnification factors 1.5, 1.25 and 1 and with the large and small focal spots. Phantom position and the dose per frame (0.12– 0.24 μ Gy/frame) were varied for a single phantom size, magnification and focal spot. Observer Model— For each experimental condition, 1200 signal-present and signal-absent images were acquired and a detectability index (d') was calculated with a Gabor-channelized Hotelling observer (CHO) model. Detectability indices were evaluated as a function of dose, phantom size, and magnification. The model was then applied to compare d' of the two imaging planes and focal spots. Uncertainty in d' was estimated by bootstrapping the data and by examining the shift-variance of systems. Results: Detectability indices varied linearly with magnification and the square root of dose. For the 2 and 4 mm phantoms, d' varied linearly with diameter. For the 0.5 and 1 mm phantoms, d' expectedly deviated from this linear relationship due to substantial detector and focal spot blurring of the phantoms. The small focal spot yielded up to 50% greater d' values than the large focal spot. For the two detectors, differences in d' did not exceed the estimated ∼7% error. Conclusions: The detectability indices predictably scaled with dose, diameter, magnification, and focal spot size and serve to validate the model. Results demonstrate statistically similar target detectability for both investigated detectors, despite differences in pixel dimensions. This CHO model provides

  20. An approach of long-view tomosynthesis in peripheral arterial angiographic examinations

    Science.gov (United States)

    Notohara, Daisuke; Nishino, Kazuyoshi; Shibata, Koichi

    2011-03-01

    Tomosynthesis (TS) has been evaluated as a useful diagnostic imaging tool for the orthopedic market and lung cancer screening. Previously, we proposed Long-View Tomosynthesis (LVTS) to apply further clinical application by expanding the reconstructed region of TS. LVTS method consists of three steps. First, it acquires multiple images while X-ray tube and Flat Panel Detector (FPD) are moving in the same linear direction simultaneously at a constant speed. Second, each image is divided into fixed length strips, and then the strips from different images having similar X-ray beam trajectory angles are stitched together. Last, multi slice coronal images are reconstructed by utilizing the Filtered Back Projection (FBP) technique from the long stitched images. The present LVTS method requires the acquisition by the constant speed motion to stitch each strip precisely. It is necessary to improve the LVTS method to apply peripheral angiographic examinations that are usually acquired at arbitrary variable speeds to chase the contrast media in the blood vessel. We propose adding the method of detecting the moved distance of frames along with anatomical structure and the method of selecting pixel values with contrast media to stitching algorithm. As a result, LVTS can extract new clinical information like 3-D structure of superficial femoral arteries and the entire blood vessel from images already acquired by routine bolus chasing techniques.