WorldWideScience

Sample records for michelson interferometer fringes

  1. Analysis of the localization of Michelson interferometer fringes using Fourier optics and temporal coherence

    International Nuclear Information System (INIS)

    Narayanamurthy, C S

    2009-01-01

    Fringes formed in a Michelson interferometer never localize in any plane, in the detector plane and in the localization plane. Instead, the fringes are assumed to localize at infinity. Except for some explanation in Principles of Optics by Born and Wolf (1964 (New York: Macmillan)), the fringe localization phenomena of Michelson's interferometer have never been analysed seriously in any book. Because Michelson's interferometer is one of the important and fundamental optical experiments taught at both undergraduate and graduate levels, it would be appropriate to explain the localization of these fringes. In this paper, we analyse the localization of Michelson interferometer fringes using Fourier optics and temporal coherence, and show that they never localize at any plane even at infinity

  2. Analysis of the Localization of Michelson Interferometer Fringes Using Fourier Optics and Temporal Coherence

    Science.gov (United States)

    Narayanamurthy, C. S.

    2009-01-01

    Fringes formed in a Michelson interferometer never localize in any plane, in the detector plane and in the localization plane. Instead, the fringes are assumed to localize at infinity. Except for some explanation in "Principles of Optics" by Born and Wolf (1964 (New York: Macmillan)), the fringe localization phenomena of Michelson's interferometer…

  3. Resolving fringe ambiguities of a wide-field Michelson interferometer using visibility measurements of a noncollimated laser beam.

    Science.gov (United States)

    Wan, Xiaoke; Wang, Ji; Ge, Jian

    2009-09-10

    An actively stabilized interferometer with a constant optical path difference is a key element in long-term astronomical observation, and resolving interference fringe ambiguities is important to produce high-precision results for the long term. We report a simple and reliable method of resolving fringe ambiguities of a wide-field Michelson interferometer by measuring the interference visibility of a noncollimated single-frequency laser beam. Theoretical analysis shows that the interference visibility is sensitive to a subfringe phase shift, and a wide range of beam arrangements is suitable for real implementation. In an experimental demonstration, a Michelson interferometer has an optical path difference of 7 mm and a converging monitoring beam has a numerical aperture of 0.045 with an incidental angle of 17 degrees. The resolution of visibility measurements corresponds to approximately 1/16 fringe in the interferometer phase shift. The fringe ambiguity-free region is extended over a range of approximately 100 fringes.

  4. Physical interpretation of the fringe shift measured on Michelson interferometer in optical media

    International Nuclear Information System (INIS)

    Demjanov, V.V.

    2010-01-01

    The shift of the interference fringe in the Michelson interferometer is absent in vacuum but present in measurements performed in dielectric media with the refractive index greater than unity. This experimental observation induced me to interpret physical processes occurred in the Michelson interferometer in a conceptually new way. I rejected the generally accepted additive rule c±v for composition of the velocity v of the inertial body and the speed c of light as inapplicable in principle to non-inertial objects which electromagnetic waves just belong to. I used instead the non-relativistic formula of Fresnel for drag of light by a moving optical medium. This formula, and taking into account the physical effect of Lorentz contraction of the arm of interferometer, enabled me to construct the theoretical model that reproduces in essential features the parabolic dependence of the shift of the interference fringe on the dielectric permittivity of the light-carrying material. The Earth's speed relative to aether found from the experimental curve was estimated as 140-480 km/s. The range of the values refers to the projection of the speed on the horizontal plane of the experimental setup measured at various time of day and night.

  5. Double-grating interferometer with a one-to-one correspondence with a Michelson interferometer.

    Science.gov (United States)

    Xu, Yande; Sasaki, Osami; Suzuki, Takamasa

    2003-10-01

    We describe a double-grating interferometer that has a one-to-one correspondence with a Michelson interferometer. The half spatial periods of the gratings are equivalent to the wavelengths of the interferometer. The widths of the interference fringes can be changed easily. The intensity distribution of the interference pattern is independent of the wavelength of the light source used. The surface profile of an object can be measured because two interference beams can coincide precisely on the image plane of the object. The measuring range is much larger than that of a Michelson interferometer.

  6. An extreme ultraviolet Michelson interferometer for experiments at free-electron lasers

    International Nuclear Information System (INIS)

    Hilbert, Vinzenz; Fuchs, Silvio; Paulus, Gerhard G.; Zastrau, Ulf; Blinne, Alexander; Feigl, Torsten; Kämpfer, Tino; Rödel, Christian; Uschmann, Ingo; Wünsche, Martin; Förster, Eckhart

    2013-01-01

    We present a Michelson interferometer for 13.5 nm soft x-ray radiation. It is characterized in a proof-of-principle experiment using synchrotron radiation, where the temporal coherence is measured to be 13 fs. The curvature of the thin-film beam splitter membrane is derived from the observed fringe pattern. The applicability of this Michelson interferometer at intense free-electron lasers is investigated, particularly with respect to radiation damage. This study highlights the potential role of such Michelson interferometers in solid density plasma investigations using, for instance, extreme soft x-ray free-electron lasers. A setup using the Michelson interferometer for pseudo-Nomarski-interferometry is proposed

  7. An extreme ultraviolet Michelson interferometer for experiments at free-electron lasers.

    Science.gov (United States)

    Hilbert, Vinzenz; Blinne, Alexander; Fuchs, Silvio; Feigl, Torsten; Kämpfer, Tino; Rödel, Christian; Uschmann, Ingo; Wünsche, Martin; Paulus, Gerhard G; Förster, Eckhart; Zastrau, Ulf

    2013-09-01

    We present a Michelson interferometer for 13.5 nm soft x-ray radiation. It is characterized in a proof-of-principle experiment using synchrotron radiation, where the temporal coherence is measured to be 13 fs. The curvature of the thin-film beam splitter membrane is derived from the observed fringe pattern. The applicability of this Michelson interferometer at intense free-electron lasers is investigated, particularly with respect to radiation damage. This study highlights the potential role of such Michelson interferometers in solid density plasma investigations using, for instance, extreme soft x-ray free-electron lasers. A setup using the Michelson interferometer for pseudo-Nomarski-interferometry is proposed.

  8. An X-ray BBB Michelson interferometer.

    Science.gov (United States)

    Sutter, John P; Ishikawa, Tetsuya; Kuetgens, Ulrich; Materlik, Gerhard; Nishino, Yoshinori; Rostomyan, Armen; Tamasaku, Kenji; Yabashi, Makina

    2004-09-01

    A new X-ray Michelson interferometer based on the BBB interferometer of Bonse and Hart and designed for X-rays of wavelength approximately 1 A was described in a previous paper. Here, a further test carried out at the SPring-8 1 km beamline BL29XUL is reported. One of the BBB's mirrors was displaced by a piezo to introduce the required path-length difference. The resulting variation of intensity with piezo voltage as measured by an avalanche photodiode could be ascribed to the phase variation resulting from the path-length change, with a small additional contribution from the change of the position of the lattice planes of the front mirror relative to the rest of the crystal. This 'Michelson fringe' interpretation is supported by the observed steady movement across the output beam of the interference fringes produced by a refractive wedge when the piezo voltage was ramped. The front-mirror displacement required for one complete fringe at the given wavelength is only 0.675 A; therefore, a quiet environment is vital for operating this device, as previous experiments have shown.

  9. SU-E-T-410: Fringe Stability and Phase Shift Measurements in a Michelson Interferometer for Optical Calorimetry

    International Nuclear Information System (INIS)

    Flores-Martinez, E; Malin, M; DeWerd, L

    2014-01-01

    Purpose: To identify the variables limiting the resolution of a Michelson interferometer used to measure phase shifts (PS) in water as part of a radiometric calorimeter. Methods: We investigated the output stability of a He-Ne laser and a laser diode. The short and long term stability of the fringe pattern in a Michelson interferometer was tested with different types of lasers, thermal insulation arrangements, damping systems and optical mounts to optimize system performance. PS were induced by electrically heating water in a 1 cm quartz cuvette located in one of the interferometer arms. The PS was calculated from fringe intensity changes and compared to a calculated PS using thermocouple-measured temperature changes in the water. Results: The intensity of the laser diode is more stable, but the gas laser’s profile is more suitable for fringe analysis and has better temporal coherence. The laser requires a warm-up time of 4 hours before its output is stabilized (SNR>95). The fringe’s stability strongly depends on the thermal insulation. When the interferometer is exposed to ambient temperature swings of 0.7 K, it is not possible to stabilize the fringe pattern. Enclosing the system in a 2.5 cm-thick Styrofoam box improves the SNR, but further insulation will be needed to increase the SNR above 50. High frequency noise is significantly reduced by damping the system.Inducing a temperature rise in water, starting at 299 K, the average temperature increase for a 2π PS is 0.29 ± 0.02 K and the proportionality constant is -21.1 ± 0.8 radians/K. This is 5.8% lower than the calculated value using the thermocouple. Conclusion: Interferometric PS measurements of temperature may provide an alternative to thermistors for water calorimetry. The resolution of the current prototype is limited by ambient temperature stability. Calculated and measured thermally-induced PS in water agreed to within 5.8%

  10. Performance evaluation of a dual fringe-imaging Michelson interferometer for air parameter measurements with a 355 nm Rayleigh-Mie lidar.

    Science.gov (United States)

    Cézard, Nicolas; Dolfi-Bouteyre, Agnès; Huignard, Jean-Pierre; Flamant, Pierre H

    2009-04-20

    A new concept of spectrum analyzer is proposed for short-range lidar measurements in airborne applications. It implements a combination of two fringe-imaging Michelson interferometers to analyze the Rayleigh-Mie spectrum backscattered by molecules and particles at 355 nm. The objective is to perform simultaneous measurements of four variables: the air speed, the air temperature and density, and the particle scattering ratio. The Cramer-Rao bounds are calculated to evaluate the best expectable measurement accuracies. The performance optimization shows that a Michelson interferometer with a path difference of 3 cm is optimal for air speed measurements in clear air. To optimize density, temperature, and scattering ratio measurements, the second interferometer should be set to a path difference of 10 cm at least; 20 cm would be better to be less sensitive to the actual Rayleigh-Brillouin line shape.

  11. Multiple reflection Michelson interferometer with picometer resolution.

    Science.gov (United States)

    Pisani, Marco

    2008-12-22

    A Michelson interferometer based on an optical set-up allowing multiple reflection between two plane mirrors performs the multiplication of the optical path by a factor N, proportionally increasing the resolution of the measurement. A multiplication factor of almost two orders of magnitude has been demonstrated with a simple set-up. The technique can be applied to any interferometric measurement where the classical interferometer limits due to fringe nonlinearities and quantum noise are an issue. Applications in precision engineering, vibration analysis, nanometrology, and spectroscopy are foreseen.

  12. Two-photon quantum interference in a Michelson interferometer

    International Nuclear Information System (INIS)

    Odate, Satoru; Wang Haibo; Kobayashi, Takayoshi

    2005-01-01

    We have observed two-photon quantum interference in a Michelson interferometer. For the first time, we experimentally demonstrated two-photon quantum interference patterns, which show the transition from nonsubwavelength interference fringes to the general subwavelength interference. At the same time, a photon bunching effect was also shown by a postselection. The |1, 1> state with a single photon in a mode corresponding to each arm of the interferometer was exclusively postselected by using path difference between two arms

  13. The Michelson interferometer-how to detect invisible interference patterns

    International Nuclear Information System (INIS)

    Verovnik, Ivo; Likar, Andrej

    2004-01-01

    In a Michelson interferometer, the contrast of the interference pattern fades away due to incoherence of light when the mirrors are not in equidistant positions. We propose an experiment where the distance between the interference fringes can be determined, even when the difference in length of the interferometer arms is far beyond the coherence length of the light, i.e. when the interference pattern disappears completely for the naked eye. We used a semiconductor laser with two photodiodes as sensors, which enabled us to follow the fluctuations of the light intensity on the screen. The distance between invisible interference fringes was determined from periodic changes of the summed fluctuating signal, obtained by changing the distance between the two sensors

  14. Quantitative phase determination by using a Michelson interferometer

    International Nuclear Information System (INIS)

    Pomarico, Juan A; Molina, Pablo F; Angelo, Cristian D'

    2007-01-01

    The Michelson interferometer is one of the best established tools for quantitative interferometric measurements. It has been, and is still successfully used, not only for scientific purposes, but it is also introduced in undergraduate courses for qualitative demonstrations as well as for quantitative determination of several properties such as refractive index, wavelength, optical thickness, etc. Generally speaking, most of the measurements are carried out by determining phase distortions through the changes in the location and/or shape of the interference fringes. However, the extreme sensitivity of this tool, for which minimum deviations of the conditions of its branches can cause very large modifications in the fringe pattern, makes phase changes difficult to follow and measure. The purpose of this communication is to show that, under certain conditions, the sensitivity of the Michelson interferometer can be 'turned down' allowing the quantitative measurement of phase changes with relative ease. As an example we present how the angle (or, optionally, the refractive index) of a transparent standard optical wedge can be determined. Experimental results are shown and compared with the data provided by the manufacturer showing very good agreement

  15. A hybrid Fabry–Perot/Michelson interferometer sensor using a dual asymmetric core microstructured fiber

    International Nuclear Information System (INIS)

    Frazão, O; Silva, S F; Viegas, J; Baptista, J M; Santos, J L; Roy, P

    2010-01-01

    A hybrid Fabry–Perot/Michelson interferometer sensor using a dual asymmetric core microstructured fiber is demonstrated. The hybrid interferometer presents three waves. Two parallel Fabry–Perot cavities with low finesse are formed between the splice region and the end of a dual-core microstructured fiber. A Michelson configuration is obtained by the two small cores of the microstructured fiber. The spectral response of the hybrid interferometer presents two pattern fringes with different frequencies due to the respective optical path interferometers. The hybrid interferometer was characterized in strain and temperature presenting different sensitivity coefficients for each topology. Due to these characteristics, this novel sensing head is able to measure strain and temperature, simultaneously

  16. Determination of refractive indices of biconvex lenses by use of a Michelson interferometer.

    Science.gov (United States)

    Chhaniwal, Vani K; Anand, Arun; Narayanamurthy, C S

    2006-06-10

    Measurements of lens parameters such as focal length, radius of curvature, and refractive index are important. We describe a measurement method that utilizes a Michelson interferometer to determine parameters of thin, convex lenses. The real fringe system formed by a Michelson interferometer is used to determine the focal lengths and the radii of curvature of the lenses. The refractive index of the lens material is determined from the thin-lens formula. We were able to determine the refractive indices to an accuracy as great as 99.97%. A detailed theoretical and experimental analysis is given.

  17. Fiber inline Michelson interferometer fabricated by a femtosecond laser.

    Science.gov (United States)

    Yuan, Lei; Wei, Tao; Han, Qun; Wang, Hanzheng; Huang, Jie; Jiang, Lan; Xiao, Hai

    2012-11-01

    A fiber inline Michelson interferometer was fabricated by micromachining a step structure at the tip of a single-mode optical fiber using a femtosecond laser. The step structure splits the fiber core into two reflection paths and produces an interference signal. A fringe visibility of 18 dB was achieved. Temperature sensing up to 1000°C was demonstrated using the fabricated assembly-free device.

  18. Feedback-stabilized fractional fringe laser interferometer for plasma density measurements

    International Nuclear Information System (INIS)

    Schneider, J.; Robertson, S.

    1979-01-01

    A feedback stabilization technique is described for a fractional fringe interferometer measuring plasma electron densities. Using this technique, a CO 2 laser Michelson interferometer with a pyroelectric detector exhibited a sensitivity of 3.4 x 10 -4 fringe on a 1-ms time scale and, due to acoustic pickup, 1.8 x 10 -2 fringe on a 10-ms time scale. The rise time is 45 μs. Stabilization against slow drifts in mirror distances is achieved by an electromechanically translated mirror driven by a servo system having a 0.2-s response time. A mechanical chopper in one of the two beam paths generates the signal which drives the servo system

  19. Correlated two-photon interference in a dual-beam Michelson interferometer

    International Nuclear Information System (INIS)

    Kwiat, P.G.; Vareka, W.A.; Hong, C.K.; Nathel, H.; Chiao, R.Y.

    1990-01-01

    We report on an interference effect arising from a two-photon entangled state produced in a potassium dihydrogen phosphate (KDP) crystal pumped by an ultraviolet argon-ion laser. Two conjugate beams of signal and idler photons were injected in a parallel configuration into a single Michelson interferometer, and detected separately by two photomultipliers, while the difference in its arm lengths was slowly scanned. The coincidence rate exhibited fringes with a visibility of nearly 50%, and a period given by half the ultraviolet (not the signal or idler) wavelength, while the singles rate exhibited no fringes

  20. In-fiber integrated Michelson interferometer.

    Science.gov (United States)

    Yuan, Libo; Yang, Jun; Liu, Zhihai; Sun, Jiaxing

    2006-09-15

    A novel fiber-optic in-fiber integrated Michelson interferometer has been proposed and demonstrated. It consists of a segment of two-core fiber with a mirrored fiber end. The sensing characteristics based on the two-core fiber bending, corresponding to the shift of the phase of the two-core in-fiber integrated Michelson interferometer, are investigated.

  1. Michelson interferometer based spatial phase shift shearography.

    Science.gov (United States)

    Xie, Xin; Yang, Lianxiang; Xu, Nan; Chen, Xu

    2013-06-10

    This paper presents a simple spatial phase shift shearography based on the Michelson interferometer. The Michelson interferometer based shearographic system has been widely utilized in industry as a practical nondestructive test tool. In the system, the Michelson interferometer is used as a shearing device to generate a shearing distance by tilting a small angle in one of the two mirrors. In fact, tilting the mirror in the Michelson interferometer also generates spatial frequency shift. Based on this feature, we introduce a simple Michelson interferometer based spatial phase shift shearography. The Fourier transform (FT) method is applied to separate the spectrum on the spatial frequency domain. The phase change due to the loading can be evaluated using a properly selected windowed inverse-FT. This system can generate a phase map of shearography by using only a single image. The effects of shearing angle, spatial resolution of couple charge device camera, and filter methods are discussed in detail. The theory and the experimental results are presented.

  2. Michelson interferometer for measuring temperature

    Science.gov (United States)

    Xie, Dong; Xu, Chunling; Wang, An Min

    2017-09-01

    We investigate that temperature can be measured by a modified Michelson interferometer, where at least one reflected mirror is replaced by a thermalized sample. Both of two mirrors replaced by the corresponding two thermalized samples can help to approximatively improve the resolution of temperature up to twice than only one mirror replaced by a thermalized sample. For further improving the precision, a nonlinear medium can be employed. The Michelson interferometer is embedded in a gas displaying Kerr nonlinearity. We obtain the analytical equations and numerically calculate the precision with parameters within the reach of current technology, proving that the precision of temperature can be greatly enhanced by using a nonlinear medium. Our results show that one can create an accurate thermometer by measuring the photons in the Michelson interferometer, with no need to directly measure the population of thermalized sample.

  3. Design of a monolithic Michelson interferometer for fringe imaging in a near-field, UV, direct-detection Doppler wind lidar.

    Science.gov (United States)

    Herbst, Jonas; Vrancken, Patrick

    2016-09-01

    The low-biased, fast, airborne, short-range, and range-resolved determination of atmospheric wind speeds plays a key role in wake vortex and turbulence mitigation strategies and would improve flight safety, comfort, and economy. In this work, a concept for an airborne, UV, direct-detection Doppler wind lidar receiver is presented. A monolithic, tilted, field-widened, fringe-imaging Michelson interferometer (FWFIMI) combines the advantages of low angular sensitivity, high thermo-mechanical stability, independence of the specific atmospheric conditions, and potential for fast data evaluation. Design and integration of the FWFIMI into a lidar receiver concept are described. Simulations help to evaluate the receiver design and prospect sufficient performance under different atmospheric conditions.

  4. Michelson interferometer for measuring temperature

    OpenAIRE

    Xie, Dong; Xu, Chunling; wang, Anmin

    2016-01-01

    We investigate that temperature can be measured by a modified Michelson interferometer, where at least one reflected mirror is replaced by a thermalized sample. Both of two mirrors replaced by the corresponding two thermalized samples can help to approximatively improve the resolution of temperature up to twice than only one mirror replaced by a thermalized sample. For further improving the precision, a nonlinear medium can be employed. The Michelson interferometer is embedded in a gas displa...

  5. Investigation of michelson interferometer for volatile organic compound sensor

    International Nuclear Information System (INIS)

    Marzuarman; Rivai, Muhammad; Sardjono, Tri Arief; Purwanto, Djoko

    2017-01-01

    The sensor device is required to monitor harmful gases in the environments and industries. Many volatile organic compounds adsorbed on the sensor material will result in changes of the optical properties including the refractive index and the film thickness. This study designed and realized a vapor detection device using the principle of Michelson Interferometer. The laser light beamed with a wavelength of 620 nm was divided by using a beam splitter. Interference occurredwhen the two separated lights were recombined. The phase difference between the two beams determined whether the interference would destruct or construct each other to produce the curved fringes. The vapor samples used in these experiments were ethanol and benzene. The results showed that the ethanol concentration of 1611-32210 ppm produced a fringe shift of 197 pixels, while the concentration of benzene of 964-19290 ppm produced a fringe shift of 273 pixels. (paper)

  6. The effect of rotations on Michelson interferometers

    Energy Technology Data Exchange (ETDEWEB)

    Maraner, Paolo, E-mail: pmaraner@unibz.it

    2014-11-15

    In the contest of the special theory of relativity, it is shown that uniform rotations induce a phase shift in Michelson interferometers. The effect is second order in the ratio of the interferometer’s speed to the speed of light, further suppressed by the ratio of the interferometer’s arms length to the radius of rotation and depends on the interferometer’s position in the co-rotating frame. The magnitude of the phase shift is just beyond the sensitivity of turntable rotated optical resonators used in present tests of Lorentz invariance. It grows significantly large in Earth’s rotated kilometer-scale Fabry–Perot enhanced interferometric gravitational-wave detectors where it appears as a constant bias. The effect can provide the means of sensing center and radius of rotations. - Highlights: • Rotations induce a phase shift in Michelson interferometers. • Earth’s rotation induces a constant bias in Michelson interferometers. • Michelson interferometers can be used to sense center and radius of rotations.

  7. The effect of rotations on Michelson interferometers

    International Nuclear Information System (INIS)

    Maraner, Paolo

    2014-01-01

    In the contest of the special theory of relativity, it is shown that uniform rotations induce a phase shift in Michelson interferometers. The effect is second order in the ratio of the interferometer’s speed to the speed of light, further suppressed by the ratio of the interferometer’s arms length to the radius of rotation and depends on the interferometer’s position in the co-rotating frame. The magnitude of the phase shift is just beyond the sensitivity of turntable rotated optical resonators used in present tests of Lorentz invariance. It grows significantly large in Earth’s rotated kilometer-scale Fabry–Perot enhanced interferometric gravitational-wave detectors where it appears as a constant bias. The effect can provide the means of sensing center and radius of rotations. - Highlights: • Rotations induce a phase shift in Michelson interferometers. • Earth’s rotation induces a constant bias in Michelson interferometers. • Michelson interferometers can be used to sense center and radius of rotations

  8. Microwave interrogated large core fused silica fiber Michelson interferometer for strain sensing.

    Science.gov (United States)

    Hua, Liwei; Song, Yang; Huang, Jie; Lan, Xinwei; Li, Yanjun; Xiao, Hai

    2015-08-20

    A Michelson-type large core optical fiber sensor has been developed, which is designed based on the optical carrier-based microwave interferometry technique, and fabricated by using two pieces of 200-μm diameter fused silica core fiber as two arms of the Michelson interferometer. The interference fringe pattern caused by the optical path difference of the two arms is interrogated in the microwave domain, where the fringe visibility of 40 dB has easily been obtained. The strain sensing at both room temperature and high temperatures has been demonstrated by using such a sensor. Experimental results show that this sensor has a linear response to the applied strain, and also has relatively low temperature-strain cross talk. The dopant-free quality of the fused silica fiber provides high possibility for the sensor to have promising strain sensing performance in a high temperature environment.

  9. Michelson Interferometer

    Science.gov (United States)

    Rogers, Ryan

    2007-01-01

    The Michelson Interferometer is a device used in many applications, but here it was used to measure small differences in distance, in the milli-inch range, specifically for defects in the Orbiter windows. In this paper, the method of using the Michelson Interferometer for measuring small distances is explained as well as the mathematics of the system. The coherence length of several light sources was calculated in order to see just how small a defect could be measured. Since white light is a very broadband source, its coherence length is very short and thus can be used to measure small defects in glass. After finding the front and back reflections from a very thin glass slide with ease and calculating the thickness of it very accurately, it was concluded that this system could find and measure small defects on the Orbiter windows. This report also discusses a failed attempt for another use of this technology as well as describes an area of promise for further analysis. The latter of these areas has applications for finding possible defects in Orbiter windows without moving parts.

  10. Adaptive DFT-Based Interferometer Fringe Tracking

    Science.gov (United States)

    Wilson, Edward; Pedretti, Ettore; Bregman, Jesse; Mah, Robert W.; Traub, Wesley A.

    2005-12-01

    An automatic interferometer fringe tracking system has been developed, implemented, and tested at the Infrared Optical Telescope Array (IOTA) Observatory at Mount Hopkins, Arizona. The system can minimize the optical path differences (OPDs) for all three baselines of the Michelson stellar interferometer at IOTA. Based on sliding window discrete Fourier-transform (DFT) calculations that were optimized for computational efficiency and robustness to atmospheric disturbances, the algorithm has also been tested extensively on offline data. Implemented in ANSI C on the 266 MHz PowerPC processor running the VxWorks real-time operating system, the algorithm runs in approximately [InlineEquation not available: see fulltext.] milliseconds per scan (including all three interferograms), using the science camera and piezo scanners to measure and correct the OPDs. The adaptive DFT-based tracking algorithm should be applicable to other systems where there is a need to detect or track a signal with an approximately constant-frequency carrier pulse. One example of such an application might be to the field of thin-film measurement by ellipsometry, using a broadband light source and a Fourier-transform spectrometer to detect the resulting fringe patterns.

  11. Adaptive DFT-Based Interferometer Fringe Tracking

    Directory of Open Access Journals (Sweden)

    Wesley A. Traub

    2005-09-01

    Full Text Available An automatic interferometer fringe tracking system has been developed, implemented, and tested at the Infrared Optical Telescope Array (IOTA Observatory at Mount Hopkins, Arizona. The system can minimize the optical path differences (OPDs for all three baselines of the Michelson stellar interferometer at IOTA. Based on sliding window discrete Fourier-transform (DFT calculations that were optimized for computational efficiency and robustness to atmospheric disturbances, the algorithm has also been tested extensively on offline data. Implemented in ANSI C on the 266 MHz PowerPC processor running the VxWorks real-time operating system, the algorithm runs in approximately 2.0 milliseconds per scan (including all three interferograms, using the science camera and piezo scanners to measure and correct the OPDs. The adaptive DFT-based tracking algorithm should be applicable to other systems where there is a need to detect or track a signal with an approximately constant-frequency carrier pulse. One example of such an application might be to the field of thin-film measurement by ellipsometry, using a broadband light source and a Fourier-transform spectrometer to detect the resulting fringe patterns.

  12. Wide Angle Michelson Doppler Imaging Interferometer (WAMDII)

    Science.gov (United States)

    Roberts, B.

    1986-01-01

    The wide angle Michelson Doppler imaging interferometer (WAMDII) is a specialized type of optical Michelson interferometer working at sufficiently long path difference to measure Doppler shifts and to infer Doppler line widths of naturally occurring upper atmospheric Gaussian line emissions. The instrument is intended to measure vertical profiles of atmospheric winds and temperatures within the altitude range of 85 km to 300 km. The WAMDII consists of a Michelson interferometer followed by a camera lens and an 85 x 106 charge coupled device photodiode array. Narrow band filters in a filter wheel are used to isolate individual line emissions and the lens forms an image of the emitting region on the charge coupled device array.

  13. A far-infrared Michelson interferometer for tokamak electron density measurements using computer-generated reference fringes

    International Nuclear Information System (INIS)

    Krug, P.A.; Stimson, P.A.; Falconer, I.S.

    1986-01-01

    A simple far-infrared interferometer which uses the 394 μm laser line from optically-pumped formic acid vapour to measure tokamak electron density is described. This interferometer is unusual in requiring only one detector and a single probing beam since reference fringes during the plasma shot are obtained by computer interpolation between the fringes observed immediately before and after the shot. Electron density has been measured with a phase resolution corresponding to + - 1/20 wavelength fringe shift, which is equivalent to a central density resolution of + - 0.1 x 10 19 m -3 for an assumed parabolic density distribution in a plasma of diameter of 0.2 m, and with a time resolution of 0.2 ms. (author)

  14. Michelson and His Interferometer

    Science.gov (United States)

    Shankland, Robert S.

    1974-01-01

    Presents a brief historical account of Michelson's invention of his interferometer with some subsequent ingenious applications of its capabilities for precise measurement discussed in details, including the experiment on detrmination of the diameters for heavenly bodies. (CC)

  15. Special topics in infrared interferometry. [Michelson interferometer development

    Science.gov (United States)

    Hanel, R. A.

    1985-01-01

    Topics in IR interferometry related to the development of a Michelson interferometer are treated. The selection and reading of the signal from the detector to the analog to digital converter is explained. The requirements for the Michelson interferometer advance speed are deduced. The effects of intensity modulation on the interferogram are discussed. Wavelength and intensity calibration of the interferometer are explained. Noise sources (Nyquist or Johnson noise, phonon noise), definitions of measuring methods of noise, and noise measurements are presented.

  16. A Michelson interferometer for ultracold neutrons

    International Nuclear Information System (INIS)

    Steyerl, A.; Malik, S.S.; Steinhauser, K.A.; Berger, L.

    1979-01-01

    We propose a neutron Michelson Interferometer installed within a focussing 'gravity diffractometer' for ultracold neutrons. In this arrangement the expected interference pattern depends only on the well-defined vertical component of neutron wavevector. Possible applications of such an interferometer are discussed. (orig.)

  17. Dual-recycled cavity-enhanced Michelson interferometer for gravitational-wave detection.

    Science.gov (United States)

    Müller, Guido; Delker, Tom; Tanner, David B; Reitze, David

    2003-03-01

    The baseline design for an Advanced Laser Interferometer Gravitational-Wave Observatory (Advanced LIGO) is a dual-recycled Michelson interferometer with cavities in each of the Michelson interferometer arms. We describe one possible length-sensing and control scheme for such a dual-recycled, cavity-enhanced Michelson interferometer. We discuss the principles of this scheme and derive the first-order sensing signals. We also present a successful experimental verification of our length-sensing system using a prototype tabletop interferometer. Our results demonstrate the robustness of the scheme against deviations from the idealized design. We also identify potential weaknesses and discuss possible improvements. These results as well as other benchtop experiments that we present form the basis for a sensing and control scheme for Advanced LIGO.

  18. Ghost reflections of Gaussian beams in anamorphic optical systems with an application to Michelson interferometer.

    Science.gov (United States)

    Abd El-Maksoud, Rania H

    2016-02-20

    In this paper, a methodology is developed to model and analyze the effect of undesired (ghost) reflections of Gaussian beams that are produced by anamorphic optical systems. The superposition of these beams with the nominal beam modulates the nominal power distribution at the recording plane. This modulation may cause contrast reduction, veiling parts of the nominal image, and/or the formation of spurious interference fringes. The developed methodology is based on synthesizing the beam optical paths into nominal and ghost optical beam paths. Similar to the nominal beam, we present the concept that each ghost beam is characterized by a beam size, wavefront radius of curvature, and Gouy phase in the paraxial regime. The nominal and ghost beams are sequentially traced through the system and formulas for estimating the electric field magnitude and phase of each ghost beam at the recording plane are presented. The effective electric field is the addition of the individual nominal and ghost electric fields. Formulas for estimating Gouy phase, the shape of the interference fringes, and the central interference order are introduced. As an application, the theory of the formation of the interference fringes by Michelson interferometer is presented. This theory takes into consideration the ghost reflections that are formed by the beam splitter. To illustrate the theory and to show its wide applicability, simulation examples that include a Mangin mirror, a Michelson interferometer, and a black box optical system are provided.

  19. The Design and Implementation of the Wide-Angle Michelson Interferometer to Observe Thermospheric Winds.

    Science.gov (United States)

    Ward, William Edmund

    The design and implementation of a Wide-Angle Michelson interferometer (WAMI) as a high spectral resolution device for measuring Doppler shifts and temperatures in the thermosphere is discussed in detail. A general theoretical framework is developed to describe the behavior of interferometers and is applied to the WAMI. Notions concerning the optical coupling of various surfaces within an interferometer are developed and used to investigate the effects of misalignments in the WAMI optics. In addition, these notions in combination with ideas on the polarization behavior of interferometers are used to suggest how complex multisurfaced interferometers might be developed, what features affect their behavior most strongly, and how this behavior might be controlled. Those aspects of the Michelson interferometer important to its use as a high resolution spectral device are outlined and expressions relating the physical features of the interferometer and the spectral features of the radiation passing through the instrument, to the form of the observed interference pattern are derived. The sensitivity of the WAMI to misalignments in its optical components is explored, and quantitative estimations of the effects of these misalignments made. A working WAMI with cube corners instead of plane mirrors was constructed and is described. The theoretical notions outlined above are applied to this instrument and found to account for most of its features. A general digital procedure is developed for the analysis of the observed interference fringes which permits an estimation of the amplitude, visibility and phase of the fringes. This instrument was taken to Bird, northern Manitoba as part of the ground based support for the Auroral Rocket and Image Excitation Study (ARIES) rocket campaign. Doppler shifts and linewidth variations in O(^1 D) and O(^1S) emissions in the aurora were observed during several nights and constitute the first synoptic wind measurements taken with a WAMI. The

  20. Mariner 9 Michelson interferometer.

    Science.gov (United States)

    Hanel, R.; Schlachman, B.; Rodgers, D.; Breihan, E.; Bywaters, R.; Chapman, F.; Rhodes, M.; Vanous, D.

    1972-01-01

    The Michelson interferometer on Mariner 9 measures the thermal emission spectrum of Mars between 200 and 2000 per cm (between 5 and 50 microns) with a spectral resolution of 2.4 per cm in the apodized mode. A noise equivalent radiance of 0.5 x 10 to the minus 7th W/sq cm/ster/cm is deduced from data recorded in orbit around Mars. The Mariner interferometer deviates in design from the Nimbus 3 and 4 interferometers in several areas, notably, by a cesium iodide beam splitter and certain aspects of the digital information processing. Special attention has been given to the problem of external vibration. The instrument performance is demonstrated by calibration data and samples of Mars spectra.

  1. Integrated fiber Michelson interferometer based on poled hollow twin-core fiber.

    Science.gov (United States)

    Liu, Zhihai; Bo, Fusen; Wang, Lei; Tian, Fengjun; Yuan, Libo

    2011-07-01

    We propose an integrated fiber Michelson interferometer based on a poled hollow twin-core fiber. The Michelson interferometer can be used as an electro-optic modulator by thermal poling one core of the twin-core fiber and introducing second-order nonlinearity in the fiber. The proposed fiber Michelson interferometer is experimentally demonstrated under driving voltages at the frequency range of 149 to 1000 Hz. The half-wave voltage of the poled fiber is 135 V, and the effective second-order nonlinear coefficient χ² is 1.23 pm/V.

  2. Development of stable monolithic wide-field Michelson interferometers.

    Science.gov (United States)

    Wan, Xiaoke; Ge, Jian; Chen, Zhiping

    2011-07-20

    Bulk wide-field Michelson interferometers are very useful for high precision applications in remote sensing and astronomy. A stable monolithic Michelson interferometer is a key element in high precision radial velocity (RV) measurements for extrasolar planets searching and studies. Thermal stress analysis shows that matching coefficients of thermal expansion (CTEs) is a critical requirement for ensuring interferometer stability. This requirement leads to a novel design using BK7 and LAK7 materials, such that the monolithic interferometer is free from thermal distortion. The processes of design, fabrication, and testing of interferometers are described in detail. In performance evaluations, the field angle is typically 23.8° and thermal sensitivity is typically -2.6×10(-6)/°C near 550 nm, which corresponds to ∼800 m/s/°C in the RV scale. Low-cost interferometer products have been commissioned in multiple RV instruments, and they are producing high stability performance over long term operations. © 2011 Optical Society of America

  3. Algorithms for Unequal-Arm Michelson Interferometers

    Science.gov (United States)

    Giampieri, Giacomo; Hellings, Ronald W.; Tinto, Massimo; Bender, Peter L.; Faller, James E.

    1994-01-01

    A method of data acquisition and data analysis is described in which the performance of Michelson-type interferometers with unequal arms can be made nearly the same as interferometers with equal arms. The method requires a separate readout of the relative phase in each arm, made by interfering the returning beam in each arm with a fraction of the outgoing beam.

  4. Optical displacement measurement with GaAs/AlGaAs-based monolithically integrated Michelson interferometers

    OpenAIRE

    Hofstetter, Daniel; Zappe, H. P.; Dändliker, René

    2008-01-01

    Two monolithically integrated optical displacement sensors fabricated in the GaAs/AlGaAs material system are reported. These single-chip microsystems are configured as Michelson interferometers and comprise a distributed Bragg reflector (DBR) laser, photodetectors, phase shifters, and waveguide couplers. While the use of a single Michelson interferometer allows measurement of displacement magnitude only, a double Michelson interferometer with two interferometer signals in phase quadrature als...

  5. EIT Based Gas Detector Design by Using Michelson Interferometer

    International Nuclear Information System (INIS)

    Abbasian, K.; Rostami, A.; Abdollahi, M. H.

    2011-01-01

    Electromagnetically induced transparency (EIT) is one of the interesting phenomena of light-matter interaction which modifies matter properties for propagation of light. In other words, we can change the absorption and refractive index (RI) in neighborhood of the resonant frequency using EIT. In this paper, we have doped 3-level quantum dots in one of the Michelson Interferometer's mirror and used EIT to change its RI. So, a controllable phase difference between lights in two arms of interferometer is created. Long response time is the main drawback of Michelson interferometer based sensor, which is resolved by this technique.

  6. Michelson interferometer based interleaver design using classic IIR filter decomposition.

    Science.gov (United States)

    Cheng, Chi-Hao; Tang, Shasha

    2013-12-16

    An elegant method to design a Michelson interferometer based interleaver using a classic infinite impulse response (IIR) filter such as Butterworth, Chebyshev, and elliptic filters as a starting point are presented. The proposed design method allows engineers to design a Michelson interferometer based interleaver from specifications seamlessly. Simulation results are presented to demonstrate the validity of the proposed design method.

  7. Naturally stable Sagnac-Michelson nonlinear interferometer.

    Science.gov (United States)

    Lukens, Joseph M; Peters, Nicholas A; Pooser, Raphael C

    2016-12-01

    Interferometers measure a wide variety of dynamic processes by converting a phase change into an intensity change. Nonlinear interferometers, making use of nonlinear media in lieu of beamsplitters, promise substantial improvement in the quest to reach the ultimate sensitivity limits. Here we demonstrate a new nonlinear interferometer utilizing a single parametric amplifier for mode mixing-conceptually, a nonlinear version of the conventional Michelson interferometer with its arms collapsed together. We observe up to 99.9% interference visibility and find evidence for noise reduction based on phase-sensitive gain. Our configuration utilizes fewer components than previous demonstrations and requires no active stabilization, offering new capabilities for practical nonlinear interferometric-based sensors.

  8. Optical refractometer based on an asymmetrical twin-core fiber Michelson interferometer.

    Science.gov (United States)

    Zhou, Ai; Zhang, Yanhui; Li, Guangping; Yang, Jun; Wang, Yuzhuo; Tian, Fengjun; Yuan, Libo

    2011-08-15

    We report and demonstrate an optical refractometer based on a compact fiber Michelson interferometer. The Michelson interferometer is composed of an asymmetrical twin-core fiber containing a central core and a side core. By chemically etching a segment of the twin-core fiber until the side core is exposed, the effective index of the side core in the etched region is sensitive to the environmental refractive index, which leads to a shift of the transmission spectrum of the Michelson interferometer. The experimental results show that such a device has a refractive index resolution of more than 800 nm/refractive index unit in the range of 1.34-1.37. © 2011 Optical Society of America

  9. Nanonewton force measurement using a modified Michelson interferometer

    International Nuclear Information System (INIS)

    Tahviliyan, Masoud; Charsooghi, Mohammad A; Akhlaghi, Ehsan A; Taghi Tavassoly, Mohammad

    2017-01-01

    In this paper, we introduce a new method to measure forces in the nanonewton range. The method is based on modification of a Michelson interferometer in which the rigid mirrors are replaced with two thin rod-like mirrors. One of the rod-like mirrors is fixed at both ends and the other has one free end. As the mirror with free end deflects in response to an applied force the spatial interference pattern is changed. Analysis of the interference fringes provides a readout of the rod deflection and thereby the applied force. The device is calibrated by applying known forces to the mirror with a free end and measuring the resulting displacement. Two different methods, mechanical and electrostatic, are used for calibration. The precision of the measurements and the propagation of the calibration uncertainty are investigated. The results show that this optical method is a good candidate for detecting small forces in the nanonewton range. (paper)

  10. Performance evaluation of a thermal Doppler Michelson interferometer system.

    Science.gov (United States)

    Mani, Reza; Dobbie, Steven; Scott, Alan; Shepherd, Gordon; Gault, William; Brown, Stephen

    2005-11-20

    The thermal Doppler Michelson interferometer is the primary element of a proposed limb-viewing satellite instrument called SWIFT (Stratospheric Wind Interferometer for Transport studies). SWIFT is intended to measure stratospheric wind velocities in the altitude range of 15-45 km. SWIFT also uses narrowband tandem etalon filters made of germanium to select a line out of the thermal spectrum. The instrument uses the same technique of phase-stepping interferometry employed by the Wind Imaging Interferometer onboard the Upper Atmosphere Research Satellite. A thermal emission line of ozone near 9 microm is used to detect the Doppler shift due to winds. A test bed was set up for this instrument that included the Michelson interferometer and the etalon filters. For the test bed work, we investigate the behavior of individual components and their combination and report the results.

  11. Nonlinear Michelson interferometer for improved quantum metrology

    OpenAIRE

    Luis, Alfredo; Rivas, Ángel

    2015-01-01

    We examine quantum detection via a Michelson interferometer embedded in a gas with Kerr nonlinearity. This nonlinear interferometer is illuminated by pulses of classical light. This strategy combines the robustness against practical imperfections of classical light with the improvement provided by nonlinear processes. Regarding ultimate quantum limits, we stress that, as a difference with linear schemes, the nonlinearity introduces pulse duration as a new variable into play along with the ene...

  12. Michelson wide-field stellar interferometry

    NARCIS (Netherlands)

    Montilla, I.

    2004-01-01

    The main goal of this thesis is to develop a system to permit wide field operation of Michelson Interferometers. A wide field of view is very important in applications such as the observation of extended or multiple objects, the fringe acquisition and/ or tracking on a nearby unresolved object, and

  13. Unequal-Arms Michelson Interferometers

    Science.gov (United States)

    Tinto, Massimo; Armstrong, J. W.

    2000-01-01

    Michelson interferometers allow phase measurements many orders of magnitude below the phase stability of the laser light injected into their two almost equal-length arms. If, however, the two arms are unequal, the laser fluctuations can not be removed by simply recombining the two beams. This is because the laser jitters experience different time delays in the two arms, and therefore can not cancel at the photo detector. We present here a method for achieving exact laser noise cancellation, even in an unequal-arm interferometer. The method presented in this paper requires a separate readout of the relative phase in each arm, made by interfering the returning beam in each arm with a fraction of the outgoing beam. By linearly combining the two data sets with themselves, after they have been properly time shifted, we show that it is possible to construct a new data set that is free of laser fluctuations. An application of this technique to future planned space-based laser interferometer detector3 of gravitational radiation is discussed.

  14. A reconfigurable optofluidic Michelson interferometer using tunable droplet grating.

    Science.gov (United States)

    Chin, L K; Liu, A Q; Soh, Y C; Lim, C S; Lin, C L

    2010-04-21

    This paper presents a novel optofluidic Michelson interferometer based on droplet microfluidics used to create a droplet grating. The droplet grating is formed by a stream of plugs in the microchannel with constant refractive index variation. It has a real-time tunability in the grating period through varying the flow rates of the liquids and index variation via different combinations of liquids. The optofluidic Michelson interferometer is highly sensitive and is suitable for the measurement of biomedical and biochemical buffer solutions. The experimental results show that it has a sensitivity of 66.7 nm per refractive index unit (RIU) and a detection range of 0.086 RIU.

  15. The Michelson Stellar Interferometer Error Budget for Triple Triple-Satellite Configuration

    Science.gov (United States)

    Marathay, Arvind S.; Shiefman, Joe

    1996-01-01

    This report presents the results of a study of the instrumentation tolerances for a conventional style Michelson stellar interferometer (MSI). The method used to determine the tolerances was to determine the change, due to the instrument errors, in the measured fringe visibility and phase relative to the ideal values. The ideal values are those values of fringe visibility and phase that would be measured by a perfect MSI and are attributable solely to the object being detected. Once the functional relationship for changes in visibility and phase as a function of various instrument errors is understood it is then possible to set limits on the instrument errors in order to ensure that the measured visibility and phase are different from the ideal values by no more than some specified amount. This was done as part of this study. The limits we obtained are based on a visibility error of no more than 1% and a phase error of no more than 0.063 radians (this comes from 1% of 2(pi) radians). The choice of these 1% limits is supported in the literture. The approach employed in the study involved the use of ASAP (Advanced System Analysis Program) software provided by Breault Research Organization, Inc., in conjunction with parallel analytical calculations. The interferometer accepts object radiation into two separate arms each consisting of an outer mirror, an inner mirror, a delay line (made up of two moveable mirrors and two static mirrors), and a 10:1 afocal reduction telescope. The radiation coming out of both arms is incident on a slit plane which is opaque with two openings (slits). One of the two slits is centered directly under one of the two arms of the interferometer and the other slit is centered directly under the other arm. The slit plane is followed immediately by an ideal combining lens which images the radiation in the fringe plane (also referred to subsequently as the detector plane).

  16. AMI: Augmented Michelson Interferometer

    Science.gov (United States)

    Furió, David; Hachet, Martin; Guillet, Jean-Paul; Bousquet, Bruno; Fleck, Stéphanie; Reuter, Patrick; Canioni, Lionel

    2015-10-01

    Experiments in optics are essential for learning and understanding physical phenomena. The problem with these experiments is that they are generally time consuming for both their construction and their maintenance, potentially dangerous through the use of laser sources, and often expensive due to high technology optical components. We propose to simulate such experiments by way of hybrid systems that exploit both spatial augmented reality and tangible interaction. In particular, we focus on one of the most popular optical experiments: the Michelson interferometer. In our approach, we target a highly interactive system where students are able to interact in real time with the Augmented Michelson Interferometer (AMI) to observe, test hypotheses and then to enhance their comprehension. Compared to a fully digital simulation, we are investigating an approach that benefits from both physical and virtual elements, and where the students experiment by manipulating 3D-printed physical replicas of optical components (e.g. lenses and mirrors). Our objective is twofold. First, we want to ensure that the students will learn with our simulator the same concepts and skills that they learn with traditional methods. Second, we hypothesis that such a system opens new opportunities to teach optics in a way that was not possible before, by manipulating concepts beyond the limits of observable physical phenomena. To reach this goal, we have built a complementary team composed of experts in the field of optics, human-computer interaction, computer graphics, sensors and actuators, and education science.

  17. Preliminary result of bunch length measurement using a modified Michelson interferometer

    International Nuclear Information System (INIS)

    Lin Xuling; Luo Feng; Bei Hua; Dai Zhimin; Chinese Academy of Sciences, Beijing; Zhang Jianbing; Lu Shanliang; Yu Tiemin

    2009-01-01

    Based on the femtosecond accelerator device which was built at the Shanghai Institute of Applied Physics (SINAP), recently a modified far infrared Michelson interferometer has been developed to measure the length of electron bunches via the optical autocorrelation method. Compared with our former normal Michelson interferometer, we use a hollow retroreflector instead of a flat mirror as the reflective mirror. The experimental setup and results of the bunch length measurement will be described in this paper. (authors)

  18. Development of high resolution Michelson interferometer for stable phase-locked ultrashort pulse pair generation.

    Science.gov (United States)

    Okada, Takumi; Komori, Kazuhiro; Goshima, Keishiro; Yamauchi, Shohgo; Morohashi, Isao; Sugaya, Takeyoshi; Ogura, Mutsuo; Tsurumachi, Noriaki

    2008-10-01

    We developed a high resolution Michelson interferometer with a two-frequency He-Ne laser positioning system in order to stabilize the relative phase of a pulse pair. The control resolution corresponded to a 12 as time resolution or a phase of 1.5 degrees at 900 nm. This high resolution Michelson interferometer can generate a phase-locked pulse pair either with a specific relative phase such as 0 or pi radians or with an arbitrary phase. Coherent control of an InAs self-assembled quantum dot was demonstrated using the high resolution Michelson interferometer with a microspectroscopy system.

  19. The comparison of environmental effects on michelson and fabry-perot interferometers utilized for the displacement measurement.

    Science.gov (United States)

    Wang, Yung-Cheng; Shyu, Lih-Horng; Chang, Chung-Ping

    2010-01-01

    The optical structure of general commercial interferometers, e.g., the Michelson interferometers, is based on a non-common optical path. Such interferometers suffer from environmental effects because of the different phase changes induced in different optical paths and consequently the measurement precision will be significantly influenced by tiny variations of the environmental conditions. Fabry-Perot interferometers, which feature common optical paths, are insensitive to environmental disturbances. That would be advantageous for precision displacement measurements under ordinary environmental conditions. To verify and analyze this influence, displacement measurements with the two types of interferometers, i.e., a self-fabricated Fabry-Perot interferometer and a commercial Michelson interferometer, have been performed and compared under various environmental disturbance scenarios. Under several test conditions, the self-fabricated Fabry-Perot interferometer was obviously less sensitive to environmental disturbances than a commercial Michelson interferometer. Experimental results have shown that induced errors from environmental disturbances in a Fabry-Perot interferometer are one fifth of those in a Michelson interferometer. This has proved that an interferometer with the common optical path structure will be much more independent of environmental disturbances than those with a non-common optical path structure. It would be beneficial for the solution of interferometers utilized for precision displacement measurements in ordinary measurement environments.

  20. Computerized evaluation optical measuring thin films by the help of Michelson`s interferometer

    Czech Academy of Sciences Publication Activity Database

    Bartoněk, L.; Keprt, Jiří

    2002-01-01

    Roč. 9, č. 2 (2002), s. 27-34 ISSN 1335-0803 R&D Projects: GA MŠk LN00A015 Institutional research plan: CEZ:AV0Z1010921 Keywords : Michelson `s interferometer * computerized evaluation Subject RIV: BH - Optics, Masers, Lasers

  1. Adaption of the Michelson interferometer for a better understanding of the temporal coherence in lasers

    Science.gov (United States)

    Illarramendi, M. A.; Zubia, J.; Arrue, J.; Ayesta, I.

    2017-08-01

    In this work, we show a design of a laboratory exercise in which a digital camera has been coupled to a Michelson interferometer based on free-propagation arms. By using the camera, our students measure the evolution of the interference patterns as a function of the difference between the optical paths of the arms. In this way, they obtain the corresponding reduction of the contrast of the fringes. The analysis of the results allows one to calculate the coherence length, and also to relate the temporal coherence of the employed laser with its spectral line profile. The exercise has been carried out with two lasers, which present different coherence lengths.

  2. Compensation of non-ideal beam splitter polarization distortion effect in Michelson interferometer

    Science.gov (United States)

    Liu, Yeng-Cheng; Lo, Yu-Lung; Liao, Chia-Chi

    2016-02-01

    A composite optical structure consisting of two quarter-wave plates and a single half-wave plate is proposed for compensating for the polarization distortion induced by a non-ideal beam splitter in a Michelson interferometer. In the proposed approach, the optimal orientations of the optical components within the polarization compensator are determined using a genetic algorithm (GA) such that the beam splitter can be treated as a free-space medium and modeled using a unit Mueller matrix accordingly. Two implementations of the proposed polarization controller are presented. In the first case, the compensator is placed in the output arm of Michelson interferometer such that the state of polarization of the interfered output light is equal to that of the input light. However, in this configuration, the polarization effects induced by the beam splitter in the two arms of the interferometer structure cannot be separately addressed. Consequently, in the second case, compensator structures are placed in the Michelson interferometer for compensation on both the scanning and reference beams. The practical feasibility of the proposed approach is introduced by considering a Mueller polarization-sensitive (PS) optical coherence tomography (OCT) structure with three polarization controllers in the input, reference and sample arms, respectively. In general, the results presented in this study show that the proposed polarization controller provides an effective and experimentally-straightforward means of compensating for the polarization distortion effects induced by the non-ideal beam splitters in Michelson interferometers and Mueller PS-OCT structures.

  3. Analysis of a four-mirror-cavity enhanced Michelson interferometer.

    Science.gov (United States)

    Thüring, André; Lück, Harald; Danzmann, Karsten

    2005-12-01

    We investigate the shot-noise-limited sensitivity of a four-mirror-cavity enhanced Michelson interferometer. The intention of this interferometer topology is the reduction of thermal lensing and the impact of the interferometers contrast although transmissive optics are used with high circulating powers. The analytical expressions describing the light fields and the frequency response are derived. Although the parameter space has 11 dimensions, a detailed analysis of the resonance feature gives boundary conditions allowing systematic parameter studies.

  4. Michelson-type Radio Interferometer for University Education

    Science.gov (United States)

    Koda, Jin; Barrett, J. W.; Hasegawa, T.; Hayashi, M.; Shafto, G.; Slechta, J.

    2013-01-01

    Despite the increasing importance of interferometry in astronomy, the lack of educational interferometers is an obstacle to training the futue generation of astronomers. Students need hands-on experiments to fully understand the basic concepts of interferometry. Professional interferometers are often too complicated for education, and it is difficult to guarantee access for classes in a university course. We have built a simple and affordable radio interferometer for education and used it for an undergraduate and graduate laboratory project. This interferometer's design is based on the Michelson & Peace's stellar optical interferometer, but operates at a radio wavelength using a commercial broadcast satellite dish and receiver. Two side mirrors are surfaced with kitchen aluminum foil and slide on a ladder, providing baseline coverage. This interferometer can resolve and measure the diameter of the Sun, a nice daytime experiment which can be carried out even under a marginal weather (i.e., partial cloud coverage). Commercial broadcast satellites provide convenient point sources. By comparing the Sun and satellites, students can learn how an interferometer works and resolves structures in the sky.

  5. System analysis of a tilted field-widened Michelson interferometer for high spectral resolution lidar.

    Science.gov (United States)

    Liu, Dong; Hostetler, Chris; Miller, Ian; Cook, Anthony; Hair, Johnathan

    2012-01-16

    High spectral resolution lidars (HSRLs) have shown great value in aircraft aerosol remote sensing application and are planned for future satellite missions. A compact, robust, quasi-monolithic tilted field-widened Michelson interferometer is being developed as the spectral discrimination filter for an second-generation HSRL(HSRL-2) at NASA Langley Research Center. The Michelson interferometer consists of a cubic beam splitter, a solid arm and an air arm. Piezo stacks connect the air arm mirror to the body of the interferometer and can tune the interferometer within a small range. The whole interferometer is tilted so that the standard Michelson output and the reflected complementary output can both be obtained. In this paper, the transmission ratio is proposed to evaluate the performance of the spectral filter for HSRL. The transmission ratios over different types of system imperfections, such as cumulative wavefront error, locking error, reflectance of the beam splitter and anti-reflection coatings, system tilt, and depolarization angle are analyzed. The requirements of each imperfection for good interferometer performance are obtained.

  6. Measurement of Refractive Index Using a Michelson Interferometer.

    Science.gov (United States)

    Fendley, J. J.

    1982-01-01

    Describes a novel and simple method of measuring the refractive index of transparent plates using a Michelson interferometer. Since it is necessary to use a computer program when determining the refractive index, undergraduates could be given the opportunity of writing their own programs. (Author/JN)

  7. Michelson Interferometer for Global High-Resolution Thermospheric Imaging (MIGHTI): Monolithic Interferometer Design and Test

    Science.gov (United States)

    Harlander, John M.; Englert, Christoph R.; Brown, Charles M.; Marr, Kenneth D.; Miller, Ian J.; Zastera, Vaz; Bach, Bernhard W.; Mende, Stephen B.

    2017-10-01

    The design and laboratory tests of the interferometers for the Michelson Interferometer for Global High-resolution Thermospheric Imaging (MIGHTI) instrument which measures thermospheric wind and temperature for the NASA-sponsored Ionospheric Connection (ICON) Explorer mission are described. The monolithic interferometers use the Doppler Asymmetric Spatial Heterodyne (DASH) Spectroscopy technique for wind measurements and a multi-element photometer approach to measure thermospheric temperatures. The DASH technique and overall optical design of the MIGHTI instrument are described in an overview followed by details on the design, element fabrication, assembly, laboratory tests and thermal control of the interferometers that are the heart of MIGHTI.

  8. Design of a Michelson Interferometer for Quantitative Refraction Index Profile Measurements

    NARCIS (Netherlands)

    Nijholt, J.L.M.

    1998-01-01

    This book describes the theoretical design of a three camera Michelson interferometer set-up for quantitative refractive index measuerments. Although a two camera system is easier to align and less expensive, a three camera interferometer is preferred because the expected measuring accuracy is much

  9. Detection method of nonlinearity errors by statistical signal analysis in heterodyne Michelson interferometer.

    Science.gov (United States)

    Hu, Juju; Hu, Haijiang; Ji, Yinghua

    2010-03-15

    Periodic nonlinearity that ranges from tens of nanometers to a few nanometers in heterodyne interferometer limits its use in high accuracy measurement. A novel method is studied to detect the nonlinearity errors based on the electrical subdivision and the analysis method of statistical signal in heterodyne Michelson interferometer. Under the movement of micropositioning platform with the uniform velocity, the method can detect the nonlinearity errors by using the regression analysis and Jackknife estimation. Based on the analysis of the simulations, the method can estimate the influence of nonlinearity errors and other noises for the dimensions measurement in heterodyne Michelson interferometer.

  10. Plasma flow velocity measurements using a modulated Michelson interferometer

    International Nuclear Information System (INIS)

    Howard, J.

    1997-01-01

    This paper discusses the possibility of flow velocity reconstruction using passive spectroscopic techniques. We report some preliminary measurements of the toroidal flow velocity of hydrogen atoms in the RTP tokamak using a phase modulated Michelson interferometer. (orig.)

  11. Quantitative Phase Determination by Using a Michelson Interferometer

    Science.gov (United States)

    Pomarico, Juan A.; Molina, Pablo F.; D'Angelo, Cristian

    2007-01-01

    The Michelson interferometer is one of the best established tools for quantitative interferometric measurements. It has been, and is still successfully used, not only for scientific purposes, but it is also introduced in undergraduate courses for qualitative demonstrations as well as for quantitative determination of several properties such as…

  12. Thermoluminescence spectra measured with a Michelson interferometer

    International Nuclear Information System (INIS)

    Haschberger, P.

    1991-01-01

    A Michelson interferometer was redesigned to prove its capabilities in the measurement of short-lived, low-intensity thermoluminescence spectra. Interferograms are collected during heating up the thermoluminescent probe in a heater plate. A personal computer controls the data acquisition and processes the Fourier transform. As the results show, even a comparatively simple and limited setup leads to relevant and reproducible spectra. (author)

  13. Guided magnonic Michelson interferometer.

    Science.gov (United States)

    Ahmed, Muhammad H; Jeske, Jan; Greentree, Andrew D

    2017-01-30

    Magnonics is an emerging field with potential applications in classical and quantum information processing. Freely propagating magnons in two-dimensional media are subject to dispersion, which limits their effective range and utility as information carriers. We show the design of a confining magnonic waveguide created by two surface current carrying wires placed above a spin-sheet, which can be used as a primitive for reconfigurable magnonic circuitry. We theoretically demonstrate the ability of such guides to counter the transverse dispersion of the magnon in a spin-sheet, thus extending the range of the magnon. A design of a magnonic directional coupler and controllable Michelson interferometer is shown, demonstrating its utility for information processing tasks.

  14. Broadband sensitivity enhancement of detuned dual-recycled Michelson interferometers with EPR entanglement

    Science.gov (United States)

    Brown, Daniel D.; Miao, Haixing; Collins, Chris; Mow-Lowry, Conor; Töyrä, Daniel; Freise, Andreas

    2017-09-01

    We demonstrate the applicability of the EPR entanglement squeezing scheme for enhancing the shot-noise-limited sensitivity of detuned dual-recycled Michelson interferometers. In particular, this scheme is applied to the GEO600 interferometer. The effect of losses throughout the interferometer, arm length asymmetries, and imperfect separation of the signal and idler beams is considered.

  15. Proposal of Michelson-Morley experiment via single photon interferometer: Interpretation of Michelson-Morley experimental results using de Broglie-Bohm picture

    OpenAIRE

    Sato, Masanori

    2004-01-01

    The Michelson-Morley experiment is considered via a single photon interferometer and we propose the interpretation of the Michelson-Morley experimental results using de Broglie-Bohm picture. We point out that the Michelson-Morley experiment revealed the interference of photons, however, it did not reveal the photons simultaneous arrival at the beam splitter. According to the de Broglie-Bohm picture, the quantum potential nonlocally determines the interference of photons. The interference of t...

  16. Enlarging the angle of view in Michelson-interferometer-based shearography by embedding a 4f system.

    Science.gov (United States)

    Wu, Sijin; He, Xiaoyuan; Yang, Lianxiang

    2011-07-20

    Digital shearography based on Michelson interferometers suffers from the disadvantage of a small angle of view due to the structure. We demonstrate a novel digital shearography system with a large angle of view. In the optical arrangement, the imaging lens is in front of the Michelson interferometer rather than behind it as in traditional digital shearography. Thus, the angle of view is no longer limited by the Michelson interferometer. The images transmitting between the separate lens and camera are accomplished by a 4f system in the new style of shearography. The influences of the 4f system on shearography are also discussed. © 2011 Optical Society of America

  17. Plasma flow velocity measurements using a modulated Michelson interferometer

    NARCIS (Netherlands)

    Howard, J.; Meijer, F. G.

    1997-01-01

    This paper discusses the possibility of flow velocity reconstruction using passive spectroscopic techniques. We report some preliminary measurements of the toroidal flow velocity of hydrogen atoms in the RTP tokamak using a phase modulated Michelson interferometer. (C) 1997 Elsevier Science S.A.

  18. Power-recycled michelson interferometer with a 50/50 grating beam splitter

    International Nuclear Information System (INIS)

    Friedrich, D; Burmeister, O; Britzger, M; Bunkowski, A; Danzmann, K; Schnabel, R; Clausnitzer, T; Fahr, S; Kley, E-B; Tuennermann, A

    2008-01-01

    We designed and fabricated an all-reflective 50/50 beam splitter based on a dielectric grating. This beam splitter was used to set up a power-recycled Michelson interferometer with a finesse of about F PR ∼ 880. Aspects of the diffractive beam splitter as well as of the interferometer design are discussed

  19. Power-recycled michelson interferometer with a 50/50 grating beam splitter

    OpenAIRE

    Friedrich, Daniel; Burmeister, O.; Britzger, M.; Bunkowski, A.; Clausnitzer, T.; Fahr, S.; Kley, E.B.; Tünnermann, A.; Danzmann, Karsten; Schnabel, Roman

    2008-01-01

    We designed and fabricated an all-reflective 50/50 beam splitter based on a dielectric grating. This beam splitter was used to set up a power-recycled Michelson interferometer with a finesse of about FPR ≈ 880. Aspects of the diffractive beam splitter as well as of the interferometer design are discussed.

  20. Michelson interferometer with diffractively-coupled arm resonators in second-order Littrow configuration.

    Science.gov (United States)

    Britzger, Michael; Wimmer, Maximilian H; Khalaidovski, Alexander; Friedrich, Daniel; Kroker, Stefanie; Brückner, Frank; Kley, Ernst-Bernhard; Tünnermann, Andreas; Danzmann, Karsten; Schnabel, Roman

    2012-11-05

    Michelson-type laser-interferometric gravitational-wave (GW) observatories employ very high light powers as well as transmissively-coupled Fabry-Perot arm resonators in order to realize high measurement sensitivities. Due to the absorption in the transmissive optics, high powers lead to thermal lensing and hence to thermal distortions of the laser beam profile, which sets a limit on the maximal light power employable in GW observatories. Here, we propose and realize a Michelson-type laser interferometer with arm resonators whose coupling components are all-reflective second-order Littrow gratings. In principle such gratings allow high finesse values of the resonators but avoid bulk transmission of the laser light and thus the corresponding thermal beam distortion. The gratings used have three diffraction orders, which leads to the creation of a second signal port. We theoretically analyze the signal response of the proposed topology and show that it is equivalent to a conventional Michelson-type interferometer. In our proof-of-principle experiment we generated phase-modulation signals inside the arm resonators and detected them simultaneously at the two signal ports. The sum signal was shown to be equivalent to a single-output-port Michelson interferometer with transmissively-coupled arm cavities, taking into account optical loss. The proposed and demonstrated topology is a possible approach for future all-reflective GW observatory designs.

  1. A Michelson interferometer for X-rays and thermal neutrons

    International Nuclear Information System (INIS)

    Appel, A.

    1992-01-01

    The introduced interferometer consists of an LLL interferometer and a phase-displacing Bragg groove component. A part of the radiation path between the Lane mirrors in the Bragg grooves is replaced by a radiation path, whose wave number vector has a slightly different direction compared to the Lane case by the refraction correction. If the angles of incidence in the two grooves are different, then a difference in path is produced between the beams producing interference. This is the first X-ray interferometer which works like an optical Michelson interferometer. As there are no basic limits to resolution by absorption or dispersion, for example, it opens up the possibility of carrying out Fourier spectroscopy in the A wavelength range. (orig.) [de

  2. Near-infrared spectral imaging Michelson interferometer for astronomical applications

    Science.gov (United States)

    Wells, C. W.; Potter, A. E.; Morgan, T. H.

    1980-01-01

    The design and operation of an imaging Michelson interferometer-spectrometer used for near-infrared (0.8 micron to 2.5 microns) spectral imaging are reported. The system employs a rapid scan interferometer modified for stable low resolution (250/cm) performance and a 42 element PbS linear detector array. A microcomputer system is described which provides data acquisition, coadding, and Fourier transformation for near real-time presentation of the spectra of all 42 scene elements. The electronic and mechanical designs are discussed and telescope performance data presented.

  3. Heterogeneous all-solid multicore fiber based multipath Michelson interferometer for high temperature sensing.

    Science.gov (United States)

    Duan, Li; Zhang, Peng; Tang, Ming; Wang, Ruoxu; Zhao, Zhiyong; Fu, Songnian; Gan, Lin; Zhu, Benpeng; Tong, Weijun; Liu, Deming; Shum, Perry Ping

    2016-09-05

    A compact high temperature sensor utilizing a multipath Michelson interferometer (MI) structure based on weak coupling multicore fiber (MCF) is proposed and experimentally demonstrated. The device is fabricated by program-controlled tapering the spliced region between single mode fiber (SMF) and a segment of MCF. After that, a spherical reflective structure is formed by arc-fusion splicing the end face of MCF. Theoretical analysis has been implemented for this specific multipath MI structure; beam propagation method based simulation and corresponding experiments were performed to investigate the effect of taper and spherical end face on system's performance. Benefiting from the multipath interferences and heterogeneous structure between the center core and surrounding cores of the all-solid MCF, an enhanced temperature sensitivity of 165 pm/°C up to 900°C and a high-quality interference spectrum with 25 dB fringe visibility were achieved.

  4. Theoretical Analysis of Interferometer Wave Front Tilt and Fringe Radiant Flux on a Rectangular Photodetector

    Directory of Open Access Journals (Sweden)

    Franz Konstantin Fuss

    2013-09-01

    Full Text Available This paper is a theoretical analysis of mirror tilt in a Michelson interferometer and its effect on the radiant flux over the active area of a rectangular photodetector or image sensor pixel. It is relevant to sensor applications using homodyne interferometry where these opto-electronic devices are employed for partial fringe counting. Formulas are derived for radiant flux across the detector for variable location within the fringe pattern and with varying wave front angle. The results indicate that the flux is a damped sine function of the wave front angle, with a decay constant of the ratio of wavelength to detector width. The modulation amplitude of the dynamic fringe pattern reduces to zero at wave front angles that are an integer multiple of this ratio and the results show that the polarity of the radiant flux changes exclusively at these multiples. Varying tilt angle causes radiant flux oscillations under an envelope curve, the frequency of which is dependent on the location of the detector with the fringe pattern. It is also shown that a fringe count of zero can be obtained for specific photodetector locations and wave front angles where the combined effect of fringe contraction and fringe tilt can have equal and opposite effects. Fringe tilt as a result of a wave front angle of 0.05° can introduce a phase measurement difference of 16° between a photodetector/pixel located 20 mm and one located 100 mm from the optical origin.

  5. Study of Fourier transform spectrometer based on Michelson interferometer wave-meter

    Science.gov (United States)

    Peng, Yuexiang; Wang, Liqiang; Lin, Li

    2008-03-01

    A wave-meter based on Michelson interferometer consists of a reference and a measurement channel. The voice-coiled motor using PID means can realize to move in stable motion. The wavelength of a measurement laser can be obtained by counting interference fringes of reference and measurement laser. Reference laser with frequency stabilization creates a cosine interferogram signal whose frequency is proportional to velocity of the moving motor. The interferogram of the reference laser is converted to pulse signal, and it is subdivided into 16 times. In order to get optical spectrum, the analog signal of measurement channel should be collected. The Analog-to-Digital Converter (ADC) for measurement channel is triggered by the 16-times pulse signal of reference laser. So the sampling rate is constant only depending on frequency of reference laser and irrelative to the motor velocity. This means the sampling rate of measurement channel signals is on a uniform time-scale. The optical spectrum of measurement channel can be processed with Fast Fourier Transform (FFT) method by DSP and displayed on LCD.

  6. Study on the wide-angle Michelson interferometer with large air gap.

    Science.gov (United States)

    Gao, Haiyang; Tang, Yuanhe; Hua, Dengxin; Liu, Hanchen

    2011-10-10

    A wide-angle Michelson interferometer with large air gap is proposed to effectively reduce the size of the glass arms and constraint on material. It provides a novel and practical instrument for ground based wind measurement of the upper atmosphere. The field widening conditions for the large air gap are calculated in theory. For the five spectral lines of 557.7 nm, 630.0 nm, 732.0 nm, 834.6 nm, and 865.7 nm, the optimal results under ideal condition are obtained with air gaps of 1.0 cm, 1.5 cm, and 2.0 cm, respectively. With the fixed optical path difference (OPD) of 7.495 cm, three pairs of glass arms are optimized. The pair with length of 1.5 cm for air gap, 5.765 cm for H-ZF12, and 2.956 cm for H-ZLaF54, has better effect of field widening than the other two pairs and its OPD variation is only within 0.30 wavelengths at incident angle of 3°. For developing a more practical wide-angle Michelson interferometer, the H-K9L glass with size of 4.445 cm is employed as the arm material of solid interferometer. The experiment for field of view of 3° is designed and the data processing and analysis for 60 images show the agreement between experimental results and theoretical simulation. The OPD variations are only within 0.27 wavelengths for image edge. The feasibility and practicality of the wide-angle Michelson interferometer with large air gap is proved by means of theory and experiment. © 2011 Optical Society of America

  7. Experimental demonstration of a variable reflectivity signal recycled Michelson interferometer for gravitational wave detection

    International Nuclear Information System (INIS)

    De Vine, G.; Shaddock, D.; McClelland, D.

    2002-01-01

    Full text: One technique of improving the sensitivity of interferometric gravitational wave detectors is to implement a signal mirror. This involves placing a mirror at the output of the Michelson interferometer. The gravitational wave signal is then 'recycled' back into the interferometer where it can coherently add with the gravitational wave signal still being produced. The frequency of the improved sensitivity is dependent on the position of the signal mirror, while the peak height and bandwidth are dependent on the reflectivity of the signal mirror. This is because the signal mirror forms a cavity with the Michelson interferometer and this cavity has a resonant frequency dependent on its length and a bandwidth dependent on its finesse, which are a function of signal mirror position and reflectivity, respectively. Due to the varying and/or unknown nature of the gravitational wave frequencies and wave-forms, it is desirable to be able to control both the peak frequency and bandwidth of the detector. The peak frequency can be easily adjusted by altering the signal mirror position. The bandwidth, however, is fixed with the signal mirror reflectivity. In a long base-line gravitational wave detector it is impractical to swap the signal mirror with one of different reflectivity for a number of reasons, for example, the detector's high vacuum would have to be broken, realignment performed and locking re-acquired. This is addressed by the proposal of two different forms of variable reflectivity signal mirror (VRSM): a Fabry-Perot cavity and a Michelson interferometer. These are analysed and the reasons for choosing to investigate the Michelson VRSM are given. The reasons include the potential for easier control and the smooth variation in reflectivity with arm length difference. The experiment is discussed and the results of the first demonstration of variable reflectivity signal recycling are presented in the form of frequency responses obtained by injecting a second

  8. Dispersed single-phase-step Michelson interferometer for Doppler imaging using sunlight.

    Science.gov (United States)

    Wan, Xiaoke; Ge, Jian

    2012-09-15

    A Michelson interferometer is dispersed with a fiber array-fed spectrograph, providing 59 Doppler sensing channels using sunlight in the 510-570 nm wavelength region. The interferometer operates at a single-phase-step mode, which is particularly advantageous in multiplexing and data processing compared to the phase-stepping mode of other interferometer spectrometer instruments. Spectral templates are prepared using a standard solar spectrum and simulated interferometer modulations, such that the correlation function with a measured 1D spectrum determines the Doppler shift. Doppler imaging of a rotating cylinder is demonstrated. The average Doppler sensitivity is ~12 m/s, with some channels reaching ~5 m/s.

  9. Michelson Interferometer (MINT)

    Science.gov (United States)

    Lacis, Andrew; Carlson, Barbara

    1993-01-01

    MINT is a Michelson interferometer designed to measure the thermal emission from the earth at high spectral resolution (2/cm) over a broad spectral range (250-1700/cm, 6-40 mu m) with contiguous 3-pixel wide (12 mrad, 8 km field of view) along-track sampling. MINT is particularly well suited for monitoring cloud properties (cloud cover, effective temperature, optical thickness, ice/water phase, and effective particle size) both day and night, as well as tropospheric water vapor, ozone, and temperature. The key instrument characteristics that make MINT ideally suited for decadal monitoring purposes are: high wavelength to wavelength precision across the full IR spectrum with high spectral resolution; space-proven long-term durability and calibration stability; and small size, low cost, low risk instrument incorporating the latest detector and electronics technology. MINT also incorporates simplicity in design and operation by utilizing passively cooled DTGS detectors and nadir viewing geometry (with target motion compensation). MINT measurement objectives, instrument characteristics, and key advantages are summarized in this paper.

  10. Quantum noise of a Michelson-Sagnac interferometer with a translucent mechanical oscillator

    International Nuclear Information System (INIS)

    Yamamoto, Kazuhiro; Friedrich, Daniel; Westphal, Tobias; Gossler, Stefan; Danzmann, Karsten; Schnabel, Roman; Somiya, Kentaro; Danilishin, Stefan L.

    2010-01-01

    Quantum fluctuations in the radiation pressure of light can excite stochastic motions of mechanical oscillators thereby realizing a linear quantum opto-mechanical coupling. When performing a precise measurement of the position of an oscillator, this coupling results in quantum radiation pressure noise. Up to now this effect has not been observed yet. Generally speaking, the strength of radiation pressure noise increases when the effective mass of the oscillator is decreased or when the power of the reflected light is increased. Recently, extremely light SiN membranes (≅100 ng) with high mechanical Q values at room temperature (≥10 6 ) have attracted attention as low thermal noise mechanical oscillators. However, the power reflectance of these membranes is much lower than unity (<0.4 at a wavelength of 1064 nm) which makes the use of advanced interferometer recycling techniques to amplify the radiation pressure noise in a standard Michelson interferometer inefficient. Here, we propose and theoretically analyze a Michelson-Sagnac interferometer that includes the membrane as a common end mirror for the Michelson interferometer part. In this topology, both power and signal recycling can be used even if the reflectance of the membrane is much lower than unity. In particular, signal recycling is a useful tool because it does not involve a power increase at the membrane. We derive the formulas for the quantum radiation pressure noise and the shot noise of an oscillator position measurement and compare them with theoretical models of the thermal noise of a SiN membrane with a fundamental resonant frequency of 75 kHz and an effective mass of125 ng. We find that quantum radiation pressure noise should be observable with a power of 1 W at the central beam splitter of the interferometer and a membrane temperature of 1 K.

  11. Optical diameters of stars measured with the Mt. Wilson Mark III interferometer

    International Nuclear Information System (INIS)

    Simon, R.S.; Mozurkewich, D.; Johnston, K.J.; Gaume, R.; Hutter, D.J.; Bowers, P.F.; Colavita, M.M.; Shao, M.

    1990-01-01

    Reliable stellar angular diameters can now be determined using the Mark III Optical Interferometer located on Mt. Wilson, California. The Mark III is a Michelson Interferometer capable of measuring the interferometric fringe visibility for stars using interferometer baselines varying from 3 to 31.5 meters in length. Angular diameters measured with the Mark III Optical Interferometer are presented for 12 stars at wavelengths of 450 and 800 nm. 10 refs

  12. Multiple spacecraft Michelson stellar interferometer

    Science.gov (United States)

    Stachnik, R. V.; Arnold, D.; Melroy, P.; Mccormack, E. F.; Gezari, D. Y.

    1984-01-01

    Results of an orbital analysis and performance assessment of SAMSI (Spacecraft Array for Michelson Spatial Interferometry) are presented. The device considered includes two one-meter telescopes in orbits which are identical except for slightly different inclinations; the telescopes achieve separations as large as 10 km and relay starlight to a central station which has a one-meter optical delay line in one interferometer arm. It is shown that a 1000-km altitude, zero mean inclination orbit affords natural scanning of the 10-km baseline with departures from optical pathlength equality which are well within the corrective capacity of the optical delay line. Electric propulsion is completely adequate to provide the required spacecraft motions, principally those needed for repointing. Resolution of 0.00001 arcsec and magnitude limits of 15 to 20 are achievable.

  13. Fast and low power Michelson interferometer thermo-optical switch on SOI.

    Science.gov (United States)

    Song, Junfeng; Fang, Q; Tao, S H; Liow, T Y; Yu, M B; Lo, G Q; Kwong, D L

    2008-09-29

    We designed and fabricated silicon-on-insulator based Michelson interferometer (MI) thermo-optical switches with deep etched trenches for heat-isolation. Switch power was reduced approximately 20% for the switch with deep etched trenches, and the MI saved approximately 50% power than that of the Mach-Zehnder interferometer. 10.6 mW switch power, approximately 42 micros switch time for the MI with deep trenches, 13.14 mW switch power and approximately 34 micros switch time for the MI without deep trenches were achieved.

  14. Simple Ultra-Low-Cost Undergraduate Holography Using a Modified Michelson Interferometer.

    Science.gov (United States)

    Rudmin, J. W.; And Others

    1980-01-01

    A technique is presented for producing holograms using equipment which is already in the possesion of the majority of college physics departments, which includes a slightly modified Michelson interferometer, a helium-neon laser, and a long focal-length lens. Production of high quality holograms has been achieved by inexperienced undergraduates…

  15. Naked eye picometer resolution in a Michelson interferometer using conjugated twisted beams.

    Science.gov (United States)

    Emile, Olivier; Emile, Janine

    2017-01-15

    Michelson interferometry is one of the most widely used techniques for accuracy measurements. Its main characteristic feature is to infer a displacement in one of the arms of the interferometer from a phase measurement. Two different twisted beams, also called vortex beams, with opposite twisted rotations in each arm of the interferometer interfere in a daisy flower-like pattern. The number of petals is twice the topological charge. Their position depends on the relative phase of the beams. Naked eye detection of 44 pm displacements is achieved. The sensitivity of such an interferometer together with possible further improvements, and applications are then discussed.

  16. Optical path difference measurements with a two-step parallel phase shifting interferometer based on a modified Michelson configuration

    Science.gov (United States)

    Toto-Arellano, Noel Ivan; Serrano-Garcia, David I.; Rodriguez-Zurita, Gustavo

    2017-09-01

    We report an optical implementation of a parallel phase-shifting quasi-common path interferometer using two modified Michelson interferometers to generate two interferograms. By using a displaceable polarizer's array, placed on the image plane, we can obtain four phase-shifted interferograms in two captures. The system operates as a quasi-common path interferometer generating four beams, which are to interfere with alignment procedures on the mirrors of the Michelson configurations. The optical phase data are retrieved using the well-known four-step algorithms. To present the capabilities of the system, experimental results obtained from transparent structures are presented.

  17. Infrared spectra of lunar soils. [using a Michelson interferometer

    Science.gov (United States)

    Aronson, J. R.; Emslie, A. G.; Smith, E. M.

    1979-01-01

    Measured data obtained by Michelson interferometer spectrometer were stored in a computer file and smoothed by being passed forward and backward through a digital four-pole low pass filter. Infrared spectra of the 10 lunar samples are presented in the format of brightness temperature versus frequency. The mol % of feldspar, pyroxene, olivine, ilmenite and ferromagnetic silicate in each sample is presented in tables. The reflectance spectra of ilmenite and enstatite are shown in graphs.

  18. Atom Michelson interferometer on a chip using a Bose-Einstein condensate.

    Science.gov (United States)

    Wang, Ying-Ju; Anderson, Dana Z; Bright, Victor M; Cornell, Eric A; Diot, Quentin; Kishimoto, Tetsuo; Prentiss, Mara; Saravanan, R A; Segal, Stephen R; Wu, Saijun

    2005-03-11

    An atom Michelson interferometer is implemented on an "atom chip." The chip uses lithographically patterned conductors and external magnetic fields to produce and guide a Bose-Einstein condensate. Splitting, reflecting, and recombining of condensate atoms are achieved by a standing-wave light field having a wave vector aligned along the atom waveguide. A differential phase shift between the two arms of the interferometer is introduced by either a magnetic-field gradient or with an initial condensate velocity. Interference contrast is still observable at 20% with an atom propagation time of 10 ms.

  19. Atom Michelson interferometer on a chip using a Bose-Einstein condensate

    International Nuclear Information System (INIS)

    Wang Yingju; Anderson, Dana Z.; Cornell, Eric A.; Diot, Quentin; Kishimoto, Tetsuo; Segal, Stephen R.; Bright, Victor M.; Saravanan, R.A.; Prentiss, Mara; Wu Saijun

    2005-01-01

    An atom Michelson interferometer is implemented on an 'atom chip'. The chip uses lithographically patterned conductors and external magnetic fields to produce and guide a Bose-Einstein condensate. Splitting, reflecting, and recombining of condensate atoms are achieved by a standing-wave light field having a wave vector aligned along the atom waveguide. A differential phase shift between the two arms of the interferometer is introduced by either a magnetic-field gradient or with an initial condensate velocity. Interference contrast is still observable at 20% with an atom propagation time of 10 ms

  20. Electrically switchable holographic liquid crystal/polymer Fresnel lens using a Michelson interferometer.

    Science.gov (United States)

    Jashnsaz, Hossein; Mohajerani, Ezeddin; Nemati, Hossein; Razavi, Seyed Hossein; Alidokht, Isa Ahmad

    2011-06-10

    A holographic technique for fabricating an electrically switchable liquid crystal/polymer composite Fresnel lens is reported. A Michelson interferometer is used to produce the required Fresnel pattern, by placing a convex lens into one path of the interferometer. Simplicity of the method and the possibility of fabricating different focal length lenses in a single arrangement are advantages of the method. The performance of the fabricated lens was demonstrated and its electro-optical properties were investigated for its primary focal length.

  1. Electron cyclotron emission measurements on JET: Michelson interferometer, new absolute calibration, and determination of electron temperature

    NARCIS (Netherlands)

    Schmuck, S.; Fessey, J.; Gerbaud, T.; Alper, B.; Beurskens, M. N. A.; de la Luna, E.; Sirinelli, A.; Zerbini, M.

    2012-01-01

    At the fusion experiment JET, a Michelson interferometer is used to measure the spectrum of the electron cyclotron emission in the spectral range 70-500 GHz. The interferometer is absolutely calibrated using the hot/cold technique and, in consequence, the spatial profile of the plasma electron

  2. Refractometric sensor based on all-fiber coaxial Michelson and Mach-Zehnder interferometers for ethanol detection in fuel

    International Nuclear Information System (INIS)

    Mosquera, L; Osorio, Jonas H; Hayashi, Juliano G; Cordeiro, Cristiano M B

    2011-01-01

    A refractometric sensor based on mechanically induced interferometers formed with long period gratings is reported. It is also shown two different setups based on a Michelson and Mach-Zehnder interferometer and its application to measure ethanol concentration in gasoline.

  3. Secondary wavelength stabilization of unbalanced Michelson interferometers for the generation of low-jitter pulse trains.

    Science.gov (United States)

    Shalloo, R J; Corner, L

    2016-09-01

    We present a double unbalanced Michelson interferometer producing up to four output pulses from a single input pulse. The interferometer is stabilized with the Hänsch-Couillaud method using an auxiliary low power continuous wave laser injected into the interferometer, allowing the stabilization of the temporal jitter of the output pulses to 0.02 fs. Such stabilized pulse trains would be suitable for driving multi-pulse laser wakefield accelerators, and the technique could be extended to include amplification in the arms of the interferometer.

  4. Streak camera recording of interferometer fringes

    International Nuclear Information System (INIS)

    Parker, N.L.; Chau, H.H.

    1977-01-01

    The use of an electronic high-speed camera in the streaking mode to record interference fringe motion from a velocity interferometer is discussed. Advantages of this method over the photomultiplier tube-oscilloscope approach are delineated. Performance testing and data for the electronic streak camera are discussed. The velocity profile of a mylar flyer accelerated by an electrically exploded bridge, and the jump-off velocity of metal targets struck by these mylar flyers are measured in the camera tests. Advantages of the streak camera include portability, low cost, ease of operation and maintenance, simplified interferometer optics, and rapid data analysis

  5. Phase correction for a Michelson interferometer with misaligned mirrors

    Science.gov (United States)

    Goorvitch, D.

    1975-01-01

    The phase correction for a Michelson interferometer with misaligned mirrors in converging light is shown to give rise to a quadratic phase shift. In general, the calculation of a spectrum from the measured interferogram needs phase correction. Phase corrections have been well worked out for the cases of a linear phase shift and a phase that is slowly varying. The standard procedures for correcting calculated spectra need to be modified, however, to remove any phase errors resulting from misaligned mirrors.

  6. Using a Michelson Interferometer to Measure Coefficient of Thermal Expansion of Copper

    Science.gov (United States)

    Scholl, Ryan; Liby, Bruce W.

    2009-01-01

    When most materials are heated they expand. This concept is usually demonstrated using some type of mechanical measurement of the linear expansion of a metal rod. We have developed an alternative laboratory method for measuring thermal expansion by using a Michelson interferometer. Using the method presented, interference, interferometry, and the…

  7. Experiments on the Porch Swing Bearing of Michelson Interferometer for Low Resolution FTIR

    OpenAIRE

    Tuomas Välikylä; Jyrki Kauppinen

    2013-01-01

    Porch swing bearing for the linear motion of the mirror in Michelson interferometer for mid-infrared low resolution Fourier transform spectrometer was studied experimentally using the modulation depth of the collimated laser beam. The mirror tilting was measured to be lower than 5 μrad over 3 mm mirror travel using two different bearings assemblies. Additionally, the manufacturing tolerances of the bearing type were proved to be loose enough not to limit the interferometer application. These ...

  8. Distributed acoustic sensing with Michelson interferometer demodulation

    Science.gov (United States)

    Liu, Xiaohui; Wang, Chen; Shang, Ying; Wang, Chang; Zhao, Wenan; Peng, Gangding; Wang, Hongzhong

    2017-09-01

    The distributed acoustic sensing (DAS) has been extensively studied and widely used. A distributed acoustic sensing system based on the unbalanced Michelson interferometer with phase generated carrier (PGC) demodulation was designed and tested. The system could directly obtain the phase, amplitude, frequency response, and location information of sound wave at the same time and measurement at all points along the sensing fiber simultaneously. Experiments showed that the system successfully measured the acoustic signals with a phase-pressure sensitivity about-148 dB (re rad/μPa) and frequency response ripple less than 1.5 dB. The further field experiment showed that the system could measure signals at all points along the sensing fiber simultaneously.

  9. Design of a birefringent Michelson interferometer-based interleaver with ultra-low dispersion and low cost.

    Science.gov (United States)

    Hu, Haocheng; Zheng, Baozhong; Liu, Qingming; Li, Yang; Wu, Li; Gu, Shijie

    2011-11-21

    We design and demonstrate a birefringent Michelson interferometer based interleaver with ultra-low dispersion and low cost. The interleaver consists of polarizing beam splitters (PBS's) and quarter-wave plates and half-wave plates. The PBS's based Michelson interferometers provide the optical path difference for interference between the two orthogonal polarization components and the half-wave plates provide the birefringent needed to minimize ripple of output. The designed interleaver with two-stage interferometer in a 50 GHz channel spacing application exhibits a 0.5 dB passband and a 25 dB stopband both 27 GHz; a channel isolation higher than 35 dB and chromatic dispersion less than ±5 ps/nm within 0.5 dB passband; 1.3 dB insertion loss and 0.3 dB PDL; 0.04 GHz/°C thermal stability. Since all of the optical components can be optically bonded together, the device is robust and easy to be aligned, which reduces labor cost. © 2011 Optical Society of America

  10. Quantum mechanical noise in coherent-state and squeezed-state Michelson interferometers

    International Nuclear Information System (INIS)

    Assaf, Ohad; Ben-Aryeh, Yacob

    2002-01-01

    In the present study we extend and generalize previous results for coherent-state and squeezed-state Michelson interferometer quantum mechanical uncertainties (or fluctuations), which are commonly referred to as 'quantum noise'. The calculation of photon counting (PC) fluctuations in the squeezed-state interferometer is extended to fourth-order correlation functions used as the measured signal. We also generalize a 'unified model' for treating both PC and radiation pressure fluctuations in the coherent-state interferometer, by using mathematical methods which apply to Kerr-type interactions. The results are more general than those reported previously in two ways. First, we obtain exact expressions, which lead to previous results under certain approximations. Second, we deal with cases in which the responses of the two mirrors to radiation pressure are not equal

  11. Reduction of quantum noise in the Michelson interferometer by use of squeezed vacuum states

    International Nuclear Information System (INIS)

    Assaf, Ohad; Ben-Aryeh, Yacob

    2002-01-01

    We develop further the unified model for treating photon-counting and radiation-pressure fluctuations in the Michelson interferometer with input of squeezed vacuum state. The dependence of the quantum fluctuations on the phase of the input light is calculated. The analysis is restricted to a single-mode interferometer, but generalized in a way that includes both harmonic-oscillator and floating mirrors. We compare our results with those of other authors

  12. Polar cap mesosphere wind observations: comparisons of simultaneous measurements with a Fabry-Perot interferometer and a field-widened Michelson interferometer.

    Science.gov (United States)

    Fisher, G M; Killeen, T L; Wu, Q; Reeves, J M; Hays, P B; Gault, W A; Brown, S; Shepherd, G G

    2000-08-20

    Polar cap mesospheric winds observed with a Fabry-Perot interferometer with a circle-to-line interferometer optical (FPI/CLIO) system have been compared with measurements from a field-widened Michelson interferometer optimized for E-region winds (ERWIN). Both instruments observed the Meinel OH emission emanating from the mesopause region (approximately 86 km) at Resolute Bay, Canada (74.9 degrees N, 94.9 degrees W). This is the first time, to our knowledge, that winds measured simultaneously from a ground-based Fabry-Perot interferometer and a ground-based Michelson interferometer have been compared at the same location. The FPI/CLIO and ERWIN instruments both have a capability for high temporal resolution (less than 10 min for a full scan in the four cardinal directions and the zenith). Statistical comparisons of hourly mean winds for both instruments by scatterplots show excellent agreement, indicating that the two optical techniques provide equivalent observations of mesopause winds. Small deviations in the measured wind can be ascribed to the different zenith angles used by the two instruments. The combined measurements illustrate the dominance of the 12-h wave in the mesopause winds at Resolute Bay, with additional evidence for strong gravity wave activity with much shorter periods (tens of minutes). Future operations of the two instruments will focus on observation of complementary emissions, providing a unique passive optical capability for the determination of neutral winds in the geomagnetic polar cap at various altitudes near the mesopause.

  13. Digital holographic amplification of interferograms in the Michelson interferometer using the phase-only LCOS modulator

    Science.gov (United States)

    Balbekin, Nikolay; Petrov, Nikolay; Pul'kin, Sergey; Shoev, Vladislav; Sevryugin, Alexander; Tursunov, Ibrohim; Venediktov, Dmitrii; Venediktov, Vladimir

    2017-10-01

    The method of amplification of hologram was applied to the so-called Rozhdestvenskiy hooks, that were obtained in the Rozhdestvenskiy interferometer (Michelson interferometer, combined with a grating spectrograph). In such a device the absorption lines reveal themselves as specific "hooks", whose curvature provides the information about the atomic oscillator force. The holographic amplification "smoothes" the hooks and thus makes their analysis much simpler.

  14. X-ray-ultraviolet beam splitters for the Michelson interferometer

    International Nuclear Information System (INIS)

    Delmotte, Franck; Ravet, Marie-Francoise; Bridou, Francoise; Varniere, Francoise; Zeitoun, Philippe; Hubert, Sebastien; Vanbostal, Laurent; Soullie, Gerard

    2002-01-01

    With the aim of realizing a Michelson interferometer working at 13.9 nm, we have developed a symmetrical beam splitter with multilayers deposited on the front and back sides of a silicon nitride membrane. On the basis of the experimental optical properties of the membrane, simulations have been performed to define the multilayer structure that provides the highest reflectivity-transmission product. Optimized Mo-Si multilayers have been successfully deposited on both sides of the membrane by use of the ion-beam sputtering technique, with a thickness-period reproducibility of 0.1 nm. Measurements by means of synchrotron radiation at 13.9 nm and at an angle of 45 deg. provide a reflectivity of 14.2% and a transmission of 15.2% for a 60% s-polarized light, close to the simulated values. Such a beam splitter has been used for x-ray laser Michelson interferometry at 13.9 nm. The first interferogram is discussed

  15. X-ray-ultraviolet beam splitters for the Michelson interferometer.

    Science.gov (United States)

    Delmotte, Franck; Ravet, Marie-Françoise; Bridou, Françoise; Varnière, Françoise; Zeitoun, Philippe; Hubert, Sébastien; Vanbostal, Laurent; Soullie, Gérard

    2002-10-01

    With the aim of realizing a Michelson interferometer working at 13.9 nm, we have developed a symmetrical beam splitter with multilayers deposited on the front and back sides of a silicon nitride membrane. On the basis of the experimental optical properties of the membrane, simulations have been performed to define the multilayer structure that provides the highest reflectivity-transmission product. Optimized Mo-Si multilayers have been successfully deposited on both sides of t he membrane by use of the ion-beam sputtering technique, with a thickness-period reproducibility of 0.1 nm. Measurements by means of synchrotron radiation at 13.9 nm and at an angle of 45 degrees provide a reflectivity of 14.2% and a transmission of 15.2% for a 60% s-polarized light, close to the simulated values. Such a beam splitter has been used for x-ray laser Michelson interferometry at 13.9 nm. The first interferogram is discussed.

  16. Broadband squeezing of quantum noise in a Michelson interferometer with Twin-Signal-Recycling.

    Science.gov (United States)

    Thüring, André; Gräf, Christian; Vahlbruch, Henning; Mehmet, Moritz; Danzmann, Karsten; Schnabel, Roman

    2009-03-15

    Twin-Signal-Recycling (TSR) builds on the resonance doublet of two optically coupled cavities and efficiently enhances the sensitivity of an interferometer at a dedicated signal frequency. We report on what we believe to be the first experimental realization of a TSR Michelson interferometer and also its broadband enhancement by squeezed light injection. The complete setup was stably locked, and a broadband quantum noise reduction of the interferometers shot noise by a factor of up to 4 dB was demonstrated. The system was characterized by measuring its quantum noise spectra for several tunings of the TSR cavities. We found good agreement between the experimental results and numerical simulations.

  17. Development of Michelson interferometer based spatial phase-shift digital shearography

    Science.gov (United States)

    Xie, Xin

    Digital shearography is a non-contact, full field, optical measurement method, which has the capability of directly measuring the gradient of deformation. For high measurement sensitivity, phase evaluation method has to be introduced into digital shearography by phase-shift technique. Catalog by phase-shift method, digital phase-shift shearography can be divided into Temporal Phase-Shift Digital Shearography (TPS-DS) and Spatial Phase-Shift Digital Shearography (SPS-DS). TPS-DS is the most widely used phase-shift shearography system, due to its simple algorithm, easy operation and good phase-map quality. However, the application of TPS-DS is only limited in static/step-by-step loading measurement situation, due to its multi-step shifting process. In order to measure the strain under dynamic/continuous loading situation, a SPS-DS system has to be developed. This dissertation aims to develop a series of Michelson Interferometer based SPS-DS measurement methods to achieve the strain measurement by using only a single pair of speckle pattern images. The Michelson Interferometer based SPS-DS systems utilize special designed optical setup to introduce extra carrier frequency into the laser wavefront. The phase information corresponds to the strain field can be separated on the Fourier domain using a Fourier Transform and can further be evaluated with a Windowed Inverse Fourier Transform. With different optical setups and carrier frequency arrangements, the Michelson Interferometer based SPS-DS method is capable to achieve a variety of measurement tasks using only single pair of speckle pattern images. Catalog by the aimed measurand, these capable measurement tasks can be divided into five categories: 1) measurement of out-of-plane strain field with small shearing amount; 2) measurement of relative out-of-plane deformation field with big shearing amount; 3) simultaneous measurement of relative out-of-plane deformation field and deformation gradient field by using multiple

  18. Superposition of helical beams by using a Michelson interferometer.

    Science.gov (United States)

    Gao, Chunqing; Qi, Xiaoqing; Liu, Yidong; Weber, Horst

    2010-01-04

    Orbital angular momentum (OAM) of a helical beam is of great interests in the high density optical communication due to its infinite number of eigen-states. In this paper, an experimental setup is realized to the information encoding and decoding on the OAM eigen-states. A hologram designed by the iterative method is used to generate the helical beams, and a Michelson interferometer with two Porro prisms is used for the superposition of two helical beams. The experimental results of the collinear superposition of helical beams and their OAM eigen-states detection are presented.

  19. [A new method of anti-jamming ability improvement for Michelson Interferometer].

    Science.gov (United States)

    Li, Yang-Jun; Lian, Su-Jie; Shi, Jia; Guo, Ya-Fei; Wang, Gao

    2014-05-01

    In order to improve anti-jamming capability of Michelson interferometer system, replace the traditional structure of the moving mirror scanning was replaced, an interference system based on electro-optic modulation of crystal refractive index was designed to achieve optical path scanning. The system modulated voltage signal on the variable refractive crystal, to generate cyclical changes, changed the refractive index to control optical path difference in the original optical path system. Using electronic scanning to replace of mechanical scanning, improved the system's noise immunity was improved. In the electro-optic modulation process, computed the maximum optical path difference of the system was computed, and analyzed of the crystal thickness and crystal diffraction efficiency of the modulation process were analyzed. The simulation experiment shows that, with the modulation voltage range increasing, the available range of the optical path is also increased, and the system spectrum resolving power will also increase accordingly. Meanwhile, in the modulation process set the modulation range was set to make the energy of diffraction energy losses less than 10% of the total energy, so as to ensure a better signal to noise ratio. Experimental results show that, as the modulation voltage changes, interference fringes occurred continuously moved. When the voltage is further increased, the nonlinear error appears. After non-linear error correction for the system, spectrum resolution reached to 7. 2 cm-1, slightly lower than the original system. But its anti-jamming capability is greatly enhanced, as in the absence of experimental platform for seismic conditions, conventional interferometer relative error is more than 20%, while the relative error of the system is less than 5%, in line with the design requirements. It was proved that the anti-jamming capability of the system was enhanced greatly, when the static electro-optical modulation was used.

  20. Modulation depth of Michelson interferometer with Gaussian beam.

    Science.gov (United States)

    Välikylä, Tuomas; Kauppinen, Jyrki

    2011-12-20

    Mirror misalignment or the tilt angle of the Michelson interferometer can be estimated from the modulation depth measured with collimated monochromatic light. The intensity of the light beam is usually assumed to be uniform, but, for example, with gas lasers it generally has a Gaussian distribution, which makes the modulation depth less sensitive to the tilt angle. With this assumption, the tilt angle may be underestimated by about 50%. We have derived a mathematical model for modulation depth with a circular aperture and Gaussian beam. The model reduces the error of the tilt angle estimate to below 1%. The results of the model have been verified experimentally.

  1. Decorrelation and fringe visibility: On the limiting behavior of varous electronic speckle pattern correlation interferometers

    DEFF Research Database (Denmark)

    Owner-Petersen, Mette

    1996-01-01

    I discuss the behavior of fringe formation in image-plane electronic speckle-pattern correlation interferometers as the limit of total decorrelation is approached. The interferometers are supposed to operate in the difference mode. The effect of decorrelation will be a decrease in fringe visibility...... until the limit of total decorrelation, when no fringes will be formed, is reached. A quantitative evaluation of the partially decorrelated fringe pattern is presented for the case of decorrelation due to both tilt and in-plane translation of an object surface element. It is shown that the fringe...

  2. Quantum Mechanical Noise in a Michelson Interferometer with Nonclassical Inputs: Nonperturbative Treatment

    Science.gov (United States)

    King, Sun-Kun

    1996-01-01

    The variances of the quantum-mechanical noise in a two-input-port Michelson interferometer within the framework of the Loudon-Ni model were solved exactly in two general cases: (1) one coherent state input and one squeezed state input, and (2) two photon number states inputs. Low intensity limit, exponential decaying signal and the noise due to mixing were discussed briefly.

  3. Improvement on a Michelson interferometer for bunch length measurement of a femtosecond accelerator

    International Nuclear Information System (INIS)

    Lin Xuling; Bei Hua; Zhang Jianbing; Dai Zhimin

    2009-01-01

    Based on the femtosecond accelerator facility at Shanghai Institute of Applied Physics (SINAP), a conventional far-infrared Michelson interferometer was built to measure the bunch length by means of optical autocorrelation. However, according to the preliminary experiment result, the resolution of interferometer is not good enough, because the mirror-driving mechanism makes the moving mirror tend to tilt or wobble as it retards. Considering of the allowable errors, we calculate the maximum allowable titling angle of the moving mirror, and discuss the alignment plan in this paper. (authors)

  4. Direct UV written Michelson interferometer for RZ signal generation using phase-to-intensity modulation conversion

    DEFF Research Database (Denmark)

    Peucheret, Christophe; Geng, Yan; Zsigri, Beata

    2005-01-01

    An integrated Michelson delay interferometer structure making use of waveguide gratings as reflective elements is proposed and fabricated by direct ultraviolet writing. Successful return-to-zero alternate-mark-inversion signal generation using phase-to-intensity modulation conversion...

  5. Electron cyclotron emission measurements on JET: Michelson interferometer, new absolute calibration, and determination of electron temperature.

    Science.gov (United States)

    Schmuck, S; Fessey, J; Gerbaud, T; Alper, B; Beurskens, M N A; de la Luna, E; Sirinelli, A; Zerbini, M

    2012-12-01

    At the fusion experiment JET, a Michelson interferometer is used to measure the spectrum of the electron cyclotron emission in the spectral range 70-500 GHz. The interferometer is absolutely calibrated using the hot/cold technique and, in consequence, the spatial profile of the plasma electron temperature is determined from the measurements. The current state of the interferometer hardware, the calibration setup, and the analysis technique for calibration and plasma operation are described. A new, full-system, absolute calibration employing continuous data acquisition has been performed recently and the calibration method and results are presented. The noise level in the measurement is very low and as a result the electron cyclotron emission spectrum and thus the spatial profile of the electron temperature are determined to within ±5% and in the most relevant region to within ±2%. The new calibration shows that the absolute response of the system has decreased by about 15% compared to that measured previously and possible reasons for this change are presented. Temperature profiles measured with the Michelson interferometer are compared with profiles measured independently using Thomson scattering diagnostics, which have also been recently refurbished and recalibrated, and agreement within experimental uncertainties is obtained.

  6. Dissipative optomechanics in a Michelson-Sagnac interferometer.

    Science.gov (United States)

    Xuereb, André; Schnabel, Roman; Hammerer, Klemens

    2011-11-18

    Dissipative optomechanics studies the coupling of the motion of an optical element to the decay rate of a cavity. We propose and theoretically explore a realization of this system in the optical domain, using a combined Michelson-Sagnac interferometer, which enables a strong and tunable dissipative coupling. Quantum interference in such a setup results in the suppression of the lower motional sideband, leading to strongly enhanced cooling in the non-sideband-resolved regime. With state-of-the-art parameters, ground-state cooling and low-power quantum-limited position transduction are both possible. The possibility of a strong, tunable dissipative coupling opens up a new route towards observation of such fundamental optomechanical effects as nonlinear dynamics. Beyond optomechanics, the suggested method can be readily transferred to other setups involving nonlinear media, atomic ensembles, or single atoms.

  7. Displacement measurement using an optoelectronic oscillator with an intra-loop Michelson interferometer.

    Science.gov (United States)

    Lee, Jehyun; Park, Sooyoung; Seo, Dae Han; Yim, Sin Hyuk; Yoon, Seokchan; Cho, D

    2016-09-19

    We report on measurement of small displacements with sub-nanometer precision using an optoelectronic oscillator (OEO) with an intra-loop Michelson interferometer. In comparison with conventional homodyne and heterodyne detection methods, where displacement appears as a power change or a phase shift, respectively, in the OEO detection, the displacement produces a shift in the oscillation frequency. In comparison with typical OEO sensors, where the frequency shift is proportional to the OEO oscillation frequency in radio-frequency domain, the frequency shift in our method with an intra-loop interferometer is proportional to an optical frequency. We constructed a hybrid apparatus and compared characteristics of the OEO and heterodyne detection methods.

  8. Transverse coherence measurement using a folded Michelson interferometer.

    Science.gov (United States)

    Dean, Jesse; Bercx, Martin; Nantel, Marc; Marjoribanks, Robin

    2007-06-01

    The transverse coherence of a 1 ps pulsed laser beam was measured using a technique involving a modified Michelson interferometer and separate reference images. Using this technique, the transverse coherence of a selected plane in the laser beam was determined, in this case at the exit of a channel in a metal foil self-drilled by the laser. Images of each arm were used as references. Through this technique, it is possible to use the interference patterns produced with uneven intensity distributions and for pulsed lasers on a single-shot basis. The results of these measurements were then shown to be in agreement with those obtained using a Young's double-slit setup.

  9. A method for the coherence measurement of the supercontinuum source using Michelson interferometer

    International Nuclear Information System (INIS)

    Semenova, V A; Tsypkin, A V; Putilin, S E; Bespalov, V G

    2014-01-01

    Coherent properties of supercontinuum sources are highly significant for various applications, including low-coherence interferometry and optical frequency metrology. We propose a fast method for the spatial and temporal self-coherence of the SC measurement using Michelson interferometer without a mirror movement. Furthermore, we present self-coherence measurements of the supercontinuum, generated in microstructured fiber at 780 nm.

  10. An interferometer for high-resolution optical surveillance from GEO - internal metrology breadboard

    Science.gov (United States)

    Bonino, L.; Bresciani, F.; Piasini, G.; Pisani, M.; Cabral, A.; Rebordão, J.; Musso, F.

    2017-11-01

    This paper describes the internal metrology breadboard development activities performed in the frame of the EUCLID CEPA 9 RTP 9.9 "High Resolution Optical Satellite Sensor" project of the WEAO Research Cell by AAS-I and INETI. The Michelson Interferometer Testbed demonstrates the possibility of achieving a cophasing condition between two arms of the optical interferometer starting from a large initial white light Optical Path Difference (OPD) unbalance and of maintaining the fringe pattern stabilized in presence of disturbances.

  11. Measurement of periodically varying ECE spectra using a Michelson interferometer

    International Nuclear Information System (INIS)

    Laurent, L.; Rodriguez, L.; Talvard, M.

    1987-01-01

    In some tokamak experiments the ECE spectrum is periodically varying. If the modulation frequency is small enough (less than 10 Hz) the plasma can be considered as quasi-stationary during the typical scan time of most of the Michelson interferometers. It is possible to measure simply ECE spectra at different times of the oscillation. We present here a technique which allows to measure smaller fluctuations at larger frequencies. However the analysis requires a large number of periods of oscillation at constant frequency and a scanning mirror moving at constant velocity

  12. Analysis of a sub-shot-noise power recycled Michelson interferometer

    International Nuclear Information System (INIS)

    McKenzie, K; Buchler, B C; Shaddock, D A; Lam, P K; McClelland, D E

    2004-01-01

    The sensitivity of interferometric gravitational wave detectors is ultimately limited by the 'quantum noise' of light. In this paper we compare results from a bench-top experiment and a theoretical model which show how squeezed states of light may be used to modify the quantum noise behaviour of a power recycled Michelson interferometer. We develop a simple theoretical model of the experiment and find close agreement of theoretical and experimental results. We measure quantum noise suppression of 2.3 dB and demonstrate the lock stability of the experiment for long periods

  13. Field-widened Michelson interferometer for spectral discrimination in high-spectral-resolution lidar: theoretical framework.

    Science.gov (United States)

    Cheng, Zhongtao; Liu, Dong; Luo, Jing; Yang, Yongying; Zhou, Yudi; Zhang, Yupeng; Duan, Lulin; Su, Lin; Yang, Liming; Shen, Yibing; Wang, Kaiwei; Bai, Jian

    2015-05-04

    A field-widened Michelson interferometer (FWMI) is developed to act as the spectral discriminator in high-spectral-resolution lidar (HSRL). This realization is motivated by the wide-angle Michelson interferometer (WAMI) which has been used broadly in the atmospheric wind and temperature detection. This paper describes an independent theoretical framework about the application of the FWMI in HSRL for the first time. In the framework, the operation principles and application requirements of the FWMI are discussed in comparison with that of the WAMI. Theoretical foundations for designing this type of interferometer are introduced based on these comparisons. Moreover, a general performance estimation model for the FWMI is established, which can provide common guidelines for the performance budget and evaluation of the FWMI in the both design and operation stages. Examples incorporating many practical imperfections or conditions that may degrade the performance of the FWMI are given to illustrate the implementation of the modeling. This theoretical framework presents a complete and powerful tool for solving most of theoretical or engineering problems encountered in the FWMI application, including the designing, parameter calibration, prior performance budget, posterior performance estimation, and so on. It will be a valuable contribution to the lidar community to develop a new generation of HSRLs based on the FWMI spectroscopic filter.

  14. A differential Michelson interferometer with orthogonal single frequency laser for nanometer displacement measurement

    International Nuclear Information System (INIS)

    Yan, Liping; Chen, Benyong; Wang, Bin

    2017-01-01

    A novel differential Michelson laser interferometer is proposed to eliminate the influence of environmental fluctuations for nanometer displacement measurement. This differential interferometer consists of two homodyne interferometers in which two orthogonal single frequency beams share common reference arm and partial measurement arm. By modulating the displacement of the common reference arm with a piezoelectric transducer, the common-mode displacement drift resulting from the environmental disturbances can be well suppressed and the measured displacement as differential-mode displacement signal is achieved. In addition, a phase difference compensation method is proposed for accurately determining the phase difference between interference signals by correcting the time interval according to the average speed in one cycle of interference signal. The nanometer displacement measurement experiments were performed to demonstrate the effectiveness and feasibility of the proposed interferometer and show that precision displacement measurement with standard deviation less than 1 nm has been achieved. (paper)

  15. An improved Michelson interferometer: smoothing out the rough spots for a more effective teaching tool

    Science.gov (United States)

    Eastman, Clarke K.

    2017-08-01

    The Michelson interferometer is a classic tool for demonstrating the wave nature of light, and it is a cornerstone of the optics curriculum. But many students' experiences with this device are higher in frustration than they are in learning. That situation motivated an effort to make aligning the tool less a test of a visual acuity and patience, and more of an introduction to optics phenomena and optical engineering. Key improvements included an added beam-splitter to accommodate multiple observers, a modified telescope to quickly and reliably obtain parallel mirrors, and a series of increasing spectral-width light sources to obtain equal path lengths. This greatly improved students' chances of success, as defined by achieving "white light fringes". When presenting these new features to the students, high importance is placed on understanding why alignment was so difficult with the original design, and why the changes made alignment easier. By exposing the rationale behind the improvements, students can observe the process of problem-solving in an optical engineering scenario. Equally important is the demonstration that solutions can be devised or adapted based on the parts at hand, and that implementations only achieve a highly "polished' state after several design iterations.

  16. Compact magnetic-field sensor based on optical microfiber Michelson interferometer and Fe3O4 nanofluid.

    Science.gov (United States)

    Deng, Ming; Sun, Xiaokang; Han, Meng; Li, Decai

    2013-02-01

    We report a magnetic-field sensor by merging the advantages of optical fiber Michelson interferometers with that of magnetic fluid. Compact and low-cost optical fiber Michelson interferometers were first fabricated by a high-frequency CO(2) laser, and then they were inserted into glass capillaries with water-based Fe(3)O(4) magnetic fluid as sensing elements. The sensing characteristics have been investigated and the experimental results show that the reflective spectrum of the fiber-magnetic sensor linearly shifted with the change of the magnetic-field strength that is perpendicular to the axial of the devices. The fiber-magnetic sensor with interference arm's diameter of 50 μm is most sensitive to the external magnetic field, and the sensitivity is up to 64.9 pm/mT, which is 20 times higher than that of 125 μm diameter.

  17. Universal Michelson Gires-Tournois interferometer optical interleaver based on digital signal processing.

    Science.gov (United States)

    Zhang, Juan; Yang, Xiaowei

    2010-03-01

    Optical interleavers based on Michelson Gires-Tournois interferometer (MGTI) with arbitrary cascaded reflectors for symmetrical or asymmetrical periodic frequency response with arbitrary duty cycles are defined as universal MGTI optical interleaver (UMGTIOI). It can significantly enhance flexibility and applicability of optical networks. A novel and simple method based on digital signal processing is proposed for the design of UMGTIOI. Different kinds of design examples are given to confirm effectiveness of the method.

  18. Increased interference fringe visibility from the post-fabrication heat treatment of a perfect crystal silicon neutron interferometer

    Science.gov (United States)

    Heacock, B.; Arif, M.; Cory, D. G.; Gnaeupel-Herold, T.; Haun, R.; Huber, M. G.; Jamer, M. E.; Nsofini, J.; Pushin, D. A.; Sarenac, D.; Taminiau, I.; Young, A. R.

    2018-02-01

    We find that annealing a previously chemically etched interferometer at 800 °C dramatically increased the interference fringe visibility from 23% to 90%. The Bragg plane misalignments were also measured before and after annealing using neutron rocking curves, showing that Bragg plane alignment was improved across the interferometer after annealing. This suggests that current interferometers with low fringe visibility may be salvageable and that annealing may become an important step in the fabrication process of future neutron interferometers, leading to less need for chemical etching and larger more exotic neutron interferometers.

  19. An ultrastable Michelson interferometer for high-resolution spectroscopy in the XUV.

    Science.gov (United States)

    Corsi, C; Liontos, I; Cavalieri, S; Bellini, M; Venturi, G; Eramo, R

    2015-02-23

    We developed an ultra-stable and accurately-controllable Michelson interferometer to be used in a deeply unbalanced arm configuration for split-pulse XUV Ramsey-type spectroscopy with high-order laser harmonics. The implemented active and passive stabilization systems allow one to reach instabilities in the nanometer range over meters of relative optical path differences. Producing precisely delayed pairs of pump pulses will generate XUV harmonic pulses that may significantly improve the achievable spectral resolution and the precision of absolute frequency measurements in the XUV.

  20. Michelson interferometer with separated inputs and outputs, double pass, and compensation

    Science.gov (United States)

    Mather, J. C.; Jennings, D. E.

    1985-01-01

    A novel configuration is proposed for a Michelson interferometer spectrometer, which will be insensitive to tilts or displacements, and which employs separated inputs and outputs and double passing for higher resolution. The great advantage of such a compensated design is a relaxation of mechanical tolerances, which is especially beneficial for instruments in hostile environments. The Atmospheric Trace Molecule Spectroscopy project, which must work reliably after being subjected to the vibrations of a Space Shuttle launch, would benefit from the use of such an instrument.

  1. Application of Young-Michelson and Brown-Twiss interferometers for determining geometric parameters of nonplanar rough objects

    NARCIS (Netherlands)

    Mandrosov, V. I.

    The possibility of using Young-Michelson and Brown-Twiss interferometers for measuring the angular dimensions and parameters of the surface shape of remote passively scattering and self-luminous nonplanar rough objects by optical radiation propagating from them is substantiated. The analysis is

  2. Frequency locking of a field-widened Michelson interferometer based on optimal multi-harmonics heterodyning.

    Science.gov (United States)

    Cheng, Zhongtao; Liu, Dong; Zhou, Yudi; Yang, Yongying; Luo, Jing; Zhang, Yupeng; Shen, Yibing; Liu, Chong; Bai, Jian; Wang, Kaiwei; Su, Lin; Yang, Liming

    2016-09-01

    A general resonant frequency locking scheme for a field-widened Michelson interferometer (FWMI), which is intended as a spectral discriminator in a high-spectral-resolution lidar, is proposed based on optimal multi-harmonics heterodyning. By transferring the energy of a reference laser to multi-harmonics of different orders generated by optimal electro-optic phase modulation, the heterodyne signal of these multi-harmonics through the FWMI can reveal the resonant frequency drift of the interferometer very sensitively within a large frequency range. This approach can overcome the locking difficulty induced by the low finesse of the FWMI, thus contributing to excellent locking accuracy and lock acquisition range without any constraint on the interferometer itself. The theoretical and experimental results are presented to verify the performance of this scheme.

  3. Optical-feedback semiconductor laser Michelson interferometer for displacement measurements with directional discrimination

    International Nuclear Information System (INIS)

    Rodrigo, Peter John; Lim, May; Saloma, Caesar

    2001-01-01

    An optical-feedback semiconductor laser Michelson interferometer (OSMI) is presented for measuring microscopic linear displacements without ambiguity in the direction of motion. The two waves from the interferometer arms, one from the reference mirror and the other from the reflecting moving target, are fed back into the lasing medium (λ=830 nm), causing variations in the laser output power. We model the OSMI into an equivalent Fabry-Perot resonator and derive the dependence of the output power (and the junction voltage) on the path difference between the two interferometer arms. Numerical and experimental results consistently show that the laser output power varies periodically (period, λ/2) with path difference. The output power variation exhibits an asymmetric behavior with the direction of motion, which is used to measure, at subwavelength resolution, the displacement vector (both amplitude and direction) of the moving sample. Two samples are considered in the experiments: (i) a piezoelectric transducer and (ii) an audio speaker

  4. A bit-rate flexible and power efficient all-optical demultiplexer realised by monolithically integrated Michelson interferometer

    DEFF Research Database (Denmark)

    Vaa, Michael; Mikkelsen, Benny; Jepsen, Kim Stokholm

    1996-01-01

    A novel bit-rate flexible and very power efficient all-optical demultiplexer using differential optical control of a monolithically integrated Michelson interferometer with MQW SOAs is demonstrated at 40 to 10 Gbit/s. Gain switched DFB lasers provide ultra stable data and control signals....

  5. Quasi zero-background tunable diode laser absorption spectroscopy employing a balanced Michelson interferometer.

    Science.gov (United States)

    Guan, Zuguang; Lewander, Märta; Svanberg, Sune

    2008-12-22

    Tunable diode laser spectroscopy (TDLS) normally observes small fractional absorptive reductions in the light flux. We show, that instead a signal increase on a zero background can be obtained. A Michelson interferometer, which is initially balanced out in destructive interference, is perturbed by gas absorption in one of its arms. Both theoretical analysis and experimental demonstration show that the proposed zero-background TDLS can improve the achievable signal-to-noise ratio.

  6. A calibration mechanism based on the principles of the Michelson interferometer micro-thrust test device

    Science.gov (United States)

    Yan, Biao; Wang, Hai; Yang, Chunlai; Wen, Li

    2017-08-01

    A micro-thrust test system based on Michelson interferometer was proposed and tested. The relationship between thrust and output voltage of the calibration component in the system was calculated and verified with numerical modeling. The fitting function of the calibration component was obtained, which will be tested during future thrust test experiments.

  7. Measurement of two-dimensional Doppler wind fields using a field widened Michelson interferometer.

    Science.gov (United States)

    Langille, Jeffery A; Ward, William E; Scott, Alan; Arsenault, Dennis L

    2013-03-10

    An implementation of the field widened Michelson concept has been applied to obtain high resolution two-dimensional (2D) images of low velocity (interferometer scanning mirror position is controlled to subangstrom precision with subnanometer repeatability using the multi-application low-voltage piezoelectric instrument control electronics developed by COM DEV Ltd.; it is the first implementation of this system as a phase stepping Michelson. In this paper the calibration and characterization of the Doppler imaging system is described and the planned implementation of this new technique for imaging 2D wind and irradiance fields using the earth's airglow is introduced. Observations of Doppler winds produced by a rotating wheel are reported and shown to be of sufficient precision for buoyancy wave observations in airglow in the mesopause region of the terrestrial atmosphere.

  8. On-Line Fringe Tracking and Prediction at IOTA

    Science.gov (United States)

    Wilson, Edward; Mah, Robert; Lau, Sonie (Technical Monitor)

    1999-01-01

    The Infrared/Optical Telescope Array (IOTA) is a multi-aperture Michelson interferometer located on Mt. Hopkins near Tucson, Arizona. To enable viewing of fainter targets, an on-line fringe tracking system is presently under development at NASA Ames Research Center. The system has been developed off-line using actual data from IOTA, and is presently undergoing on-line implementation at IOTA. The system has two parts: (1) a fringe tracking system that identifies the center of a fringe packet by fitting a parametric model to the data; and (2) a fringe packet motion prediction system that uses characteristics of past fringe packets to predict fringe packet motion. Combined, this information will be used to optimize on-line the scanning trajectory, resulting in improved visibility of faint targets. Fringe packet identification is highly accurate and robust (99% of the 4000 fringe packets were identified correctly, the remaining 1% were either out of the scan range or too noisy to be seen) and is performed in 30-90 milliseconds on a Pentium II-based computer. Fringe packet prediction, currently performed using an adaptive linear predictor, delivers a 10% improvement over the baseline of predicting no motion.

  9. Development of a control scheme of homodyne detection for extracting ponderomotive squeezing from a Michelson interferometer

    International Nuclear Information System (INIS)

    Sakata, Shihori; Kawamura, Seiji; Sato, Shuichi; Somiya, Kentaro; Arai, Koji; Fukushima, Mitsuhiro; Sugamoto, Akio

    2006-01-01

    We developed a control scheme of homodyne detection. To operate the homodyne detector as easy as possible, a simple Michelson interferometer is used. Here a motivation that the control scheme of the homodyne detection is developed is for our future experiment of extracting the ponderomotively squeezed vacuum fluctuations. To obtain the best signalto- noise ratio using the homodyne detection, the homodyne phase should be optimized. The optimization of the homodyne phase is performed by changing a phase of a local oscillator for the homodyne detection from a point at which a signal is maximized. In fact, in this experiment, using the developed control scheme, we locked the Michelson interferometer with the homodyne detector and changed the phase of the local oscillator for the homodyne detection. Then, we measured signals quantity changed by changing the phase of the local oscillator for the homodyne detection. Here we used the output from the homodyne detection as the signal

  10. The tempo-spatially modulated polarization atmosphere Michelson interferometer.

    Science.gov (United States)

    Zhang, ChunMin; Zhu, HuaChun; Zhao, Baochang

    2011-05-09

    A space-based tempo-spatially modulated polarization atmosphere Michelson interferometer (TSMPAMI) is described. It uses the relative movement between the TSMPAMI and the measured target to change optical path difference. The acquisition method of interferogram is presented. The atmospheric temperatures and horizontal winds can be derived from the optical observations. The measurement errors of the winds and temperatures are discussed through simulations. In the presence of small-scale structures of the atmospheric fields, the errors are found to be significantly influenced by the mismatch of the scenes observed by the adjacent CCD sub-areas aligned along the orbiter's track during successive measurements due to the orbital velocity and the exposure time. For most realistic conditions of the orbit and atmosphere, however, the instrument is proven suitable for measuring the atmospheric parameters. © 2011 Optical Society of America

  11. Development of a phase counter with real-time fringe jump corrector for heterodyne interferometer on LHD

    International Nuclear Information System (INIS)

    Ito, Y.; Tanaka, K.; Tokuzawa, T.; Akiyama, T.; Okajima, S.; Kawahata, K.

    2005-01-01

    Phase counters, which are used with heterodyne interferometers for plasma density measurements, frequently suffer from phase jumping and cause difficulties for data interpretation. An automatic fringe jump corrector (AFJC) circuit has been developed to compensate for fringe jumps. The AFJC can correct phase jumps automatically in real-time. The AFJC, which is integrated on one chip, is installed on the presently working phase counter circuit. As for the specification of this phase counter the intermediate beat signal is 1 MHz, the phase detection range is 31 fringes with phase resolution of 1/80 of a fringe and the response time of 10 μs. The circuit has been tested on the far infrared (FIR) laser interferometer on LHD. The AFJC works fine to correct fringe jumps, when fringe jumps occurred due to the strong density gradient produced by the hydrogen pellet injection

  12. A compact, high resolution Michelson interferometer for atmospheric spectroscopy in the near ultraviolet

    Science.gov (United States)

    Sander, Stanley P.; Cageao, Richard P.; Friedl, Randall R.

    1993-01-01

    A new, compact Fourier Transform Michelson interferometer (FTUV) with an apodized resolving power greater than 300,000 at 300 nm, high throughput and wide spectral coverage has been developed. The objectives include atmospheric spectroscopy (direct solar absorption and solar scattering) and laboratory spectroscopy of transient species. In this paper, we will briefly describe the prototype FTUV instrument and the results of preliminary laboratory investigations of OH and ClO spectra in emission and absorption.

  13. Wide angle Michelson Doppler imaging interferometer. [measuring atmospheric emissions

    Science.gov (United States)

    Shepherd, G. G.

    1980-01-01

    The optical system, stepping control, phase and modulation depth, array detector, and directions sensor are described for a specialized type of Michelson interferometer which works at sufficiently high resolution to measure the line widths and Doppler shifts of naturally occurring atmospheric emissions. With its imaging capability, the instrument can potentially supply this data independently for each element of the 100 x 100 detector array. The experiment seeks: (1) to obtain vertical profiles of atmospheric winds and temperatures as functions of latitude by observing near the limb; (2) to acquire exploratory wind and temperature data on smaller scale structures in airglow irregularities and in auroral forms; and (3) to collaborate with other Spacelab experiments, such as barium cloud releases, in providing wind and temperature data.

  14. Achieving resonance in the Advanced LIGO gravitational-wave interferometer

    International Nuclear Information System (INIS)

    Staley, A; Martynov, D; Abbott, R; Adhikari, R X; Arai, K; Brooks, A F; Ballmer, S; Barsotti, L; Evans, M; Fritschel, P; DeRosa, R T; Effler, A; Dwyer, S; Gray, C; Izumi, K; Frolov, V V; Guido, C J; Heintze, M; Gustafson, R; Hoak, D

    2014-01-01

    Interferometric gravitational-wave detectors are complex instruments comprised of a Michelson interferometer enhanced by multiple coupled cavities. Active feedback control is required to operate these instruments and keep the cavities locked on resonance. The optical response is highly nonlinear until a good operating point is reached. The linear operating range is between 0.01% and 1% of a fringe for each degree of freedom. The resonance lock has to be achieved in all five degrees of freedom simultaneously, making the acquisition difficult. Furthermore, the cavity linewidth seen by the laser is only ∼1 Hz, which is four orders of magnitude smaller than the linewidth of the free running laser. The arm length stabilization system is a new technique used for arm cavity locking in Advanced LIGO. Together with a modulation technique utilizing third harmonics to lock the central Michelson interferometer, the Advanced LIGO detector has been successfully locked and brought to an operating point where detecting gravitational-waves becomes feasible. (paper)

  15. The use of balanced homodyne and squeezed states for detecting weak optical signals in a Michelson interferometer

    International Nuclear Information System (INIS)

    Ben-Aryeh, Y.

    2011-01-01

    The possibility of using squeezed states and balanced homodyne detection of optical signals in a Michelson interferometer is discussed. The present analysis describes photon statistics measurements effects related to quadrature balanced homodyne detection showing the advantage of using this scheme for detecting weak optical signals.

  16. Temporal characterization of short-pulse third-harmonic generation in an atomic gas by a transmission-grating Michelson interferometer.

    Science.gov (United States)

    Papadogiannis, N A; Nersisyan, G; Goulielmakis, E; Rakitzis, T P; Hertz, E; Charalambidis, D; Tsakiris, G D; Witte, K

    2002-09-01

    By use of a transmission-grating-based Michelson interferometer, second-order interferometric as well as intensity autocorrelation traces of the third harmonic of a Ti:sapphire 50-fs laser beam produced in Ar have been measured. The duration of the harmonic is found to be that expected from lowest-order perturbation theory. At this wavelength, the performance of the interferometer with respect to pulse-front distortion and dispersion is found to be satisfactory. This result is a first step toward the use of the interferometer for the temporal characterization of higher harmonics or harmonic superposition forming attosecond pulse trains.

  17. Elimination of drift in a fiber-Bragg-grating-based multiplexed Michelson interferometer measurement system.

    Science.gov (United States)

    Ren, Junyu; Xie, Fang; Chen, Zhimin

    2010-02-01

    Random phase drift in single-mode optical fiber interferometers used with measurement systems, which is resulted from various types of environmental disturbances, should be eliminated in order to obtain high measurement precision. We propose an optical fiber interferometric measurement system which has the function of self-eliminating the random phase drift and is stable and robust enough for real-time precision measurement. By employing the characteristics of fiber Bragg gratings, the system interleaves two fiber Michelson interferometers together that share the common-interferometric-optical path. The signal of one of the interferometers is used to stabilize the system while the signal of the other interferometer is used for measurement. An electronic feedback loop for the stabilizing action is designed. The bandwidth of the feedback loop is 5 kHz, sufficiently wide to eliminate random phase drift resulted from various environmental disturbances. The system is endowed with high stability and therefore suitable for real-time precision measurement. By means of an active phase tracking technique to measure displacement, the linear regression coefficient of the displacement measurement results is 0.9998.

  18. Michelson interferometer vibrometer using self-correcting synthetic-heterodyne demodulation.

    Science.gov (United States)

    Connelly, Michael J; Galeti, José Henrique; Kitano, Cláudio

    2015-06-20

    Synthetic-heterodyne demodulation is a useful technique for dynamic displacement and velocity detection in interferometric sensors, as it can provide an output signal that is immune to interferometric drift. With the advent of cost-effective, high-speed real-time signal-processing systems and software, processing of the complex signals encountered in interferometry has become more feasible. In synthetic heterodyne, to obtain the actual dynamic displacement or vibration of the object under test requires knowledge of the interferometer visibility and also the argument of two Bessel functions. In this paper, a method is described for determining the former and setting the Bessel function argument to a set value, which ensures maximum sensitivity. Conventional synthetic-heterodyne demodulation requires the use of two in-phase local oscillators; however, the relative phase of these oscillators relative to the interferometric signal is unknown. It is shown that, by using two additional quadrature local oscillators, a demodulated signal can be obtained that is independent of this phase difference. The experimental interferometer is a Michelson configuration using a visible single-mode laser, whose current is sinusoidally modulated at a frequency of 20 kHz. The detected interferometer output is acquired using a 250 kHz analog-to-digital converter and processed in real time. The system is used to measure the displacement sensitivity frequency response and linearity of a piezoelectric mirror shifter over a range of 500 Hz to 10 kHz. The experimental results show good agreement with two data-obtained independent techniques: the signal coincidence and denominated n-commuted Pernick method.

  19. WAMDII: The Wide Angle Michelson Doppler Imaging Interferometer

    Science.gov (United States)

    1992-01-01

    As part of an effort to learn more about the upper atmosphere and how it is linked to the weather experienced each day, NASA and NRCC are jointly sponsoring the Wide Angle Michelson Doppler Imaging Interferometer (WAMDII) Mission. WAMDII will measure atmospheric temperature and wind speed in the upper atmosphere. In addition to providing data on the upper atmosphere, the wind speed and temperature readings WAMDII takes will also be highly useful in developing and updating computer simulated models of the upper atmosphere. These models are used in the design and testing of equipment and software for Shuttles, satellites, and reentry vehicles. In making its wind speed and temperature measurements, WAMDII examines the Earth's airglow, a faint photochemical luminescence caused by the influx of solar ultraviolet energy into the upper atmosphere. During periods of high solar flare activity, the amount of this UV energy entering the upper atmosphere increases, and this increase may effect airglow emissions.

  20. Study of optically thin electron cyclotron emission from TFTR using a Michelson interferometer

    International Nuclear Information System (INIS)

    Stauffer, F.J.; Boyd, D.A.

    1986-01-01

    The TFTR Michelson interferometer, which is used as an electron temperature diagnostic, has a spectral range of 75-540 GHz. This range is adequate for measuring at least the first three cyclotron harmonics, and it spans both optically thick and thin portions of the ECE spectrum. During the most recent opening of the TFTR vacuum vessel, a concave, carbon reflector was installed on the back wall of the vessel, opposite the light collecting optic of the Michelson system. The reflector is designed to prevent the observation of optically thin ECE that originates from a location that is outside the field of view of the light collecting optic. If this is achieved, it should be possible to derive the electron density profile from measurements of either the extraordinary mode third harmonic or the ordinary mode second harmonic. An analysis of ECE spectra that have been measured before and after installation of the reflector is presented

  1. First mesospheric wind images using the Michelson interferometer for airglow dynamics imaging.

    Science.gov (United States)

    Langille, J A; Ward, W E; Nakamura, T

    2016-12-10

    The Michelson interferometer for airglow dynamics imaging (MIADI) is a ground-based instrument that combines an imaging capability with the Doppler Michelson interferometry in order to remotely detect motions in the mesopause region using spectrally isolated airglow emissions: the O(S1) emission at 557.73 nm and the OH (6, 2) P1 (2) at 839.918 nm. A measurement and analysis approach has been developed that allows simultaneous images of the line-of-sight Doppler wind field and irradiance field to be obtained. A working field instrument was installed and tested at a field site outside Fredericton, NB (45.96 N, 66.65 W) during the summer of 2014. Successful measurements over a 6 h period were obtained on 31 July 2014. This paper describes the MIADI measurement and analysis approach and presents the work that has been done to extract images of the line-of-sight Doppler wind field and irradiances from these observations. The imaging capability is validated by identifying the presence of large-scale and small-scale geophysical perturbations in the images.

  2. A comparison of delayed self-heterodyne interference measurement of laser linewidth using Mach-Zehnder and Michelson interferometers.

    Science.gov (United States)

    Canagasabey, Albert; Michie, Andrew; Canning, John; Holdsworth, John; Fleming, Simon; Wang, Hsiao-Chuan; Aslund, Mattias L

    2011-01-01

    Linewidth measurements of a distributed feedback (DFB) fibre laser are made using delayed self heterodyne interferometry (DHSI) with both Mach-Zehnder and Michelson interferometer configurations. Voigt fitting is used to extract and compare the Lorentzian and Gaussian linewidths and associated sources of noise. The respective measurements are w(L) (MZI) = (1.6 ± 0.2) kHz and w(L) (MI) = (1.4 ± 0.1) kHz. The Michelson with Faraday rotator mirrors gives a slightly narrower linewidth with significantly reduced error. This is explained by the unscrambling of polarisation drift using the Faraday rotator mirrors, confirmed by comparing with non-rotating standard gold coated fibre end mirrors.

  3. Measuring the separation of the sodium D-doublet with a Michelson interferometer

    Science.gov (United States)

    D'Anna, M.; Corridoni, T.

    2018-01-01

    Revisiting a method proposed by Fizeau in 1862, in this paper we measure the separation of the Na-doublet (the wavelength difference {{Δ }}λ between the two emission D-lines of the sodium spectrum) with a didactical Michelson interferometer. We describe the setup, how the measurements have been done and develop a mathematical model in order to explain the principal features of the collected data. Discussing the limits of this model, we suggest further experimental and theoretical extensions of the experience, also focusing on the didactical aspects to show how this experiment could bring advanced modern physics topics into high schools.

  4. A Michelson interferometer/polarimeter on the Tokamak Fusion Test Reactor (TFTR)

    International Nuclear Information System (INIS)

    Park, H.K.; Mansfield, D.K.; Johnson, L.C.; Ma, C.H.

    1987-01-01

    A multichannel interferometer/polarimeter for the Tokamak Fusion Test Reactor (TFTR) has been developed in order to study the time dependent plasma current density (J/sub p/) and electron density (n/sub e/) profile simultaneously. The goal of the TFTR is demonstration of breakeven via dueuterium and tritium (DT) plasma. In order to be operated and maintained during DT operation phase, the system is designed based on the Michelson geometry which possesses intrinsic standing wave problems. So far, there has been no observable signals due to these standing waves. However, a standing wave resulted from the beam path design to achieve a optimum use of the laser power was found. This standing wave has not prevented initial 10 channel interferometer operation. However, a single channel polarimeter test indicated this standing wave was fatal for Faraday notation measurements. Techniques employing 1/2 wave plates and polarizers have been applied to eliminate this standing wave problem. The completion of 10 channel Faraday rotation measurements may be feasible in the near future

  5. A study of a space-station-associated multiple spacecraft Michelson spatial interferometer

    Science.gov (United States)

    Stachnik, R. V.

    1983-01-01

    One approach to Michelson spatial interferometry at optical wavelengths involves use of an array of spacecraft in which two widely-separated telescopes collect light from a star and direct it to a third, centrally-located, device which combines the beams in order to detect and measure interference fringes. The original version of a spacecraft array for Michelson spatial interferometry (SAMSI) was modified so that the system uses the fuel resupply capability of a space station. The combination of this fuel resupply capability with a method of obtaining image Fourier transform phase information, necessary for full image reconstruction, permits SAMSI to be used to synthesize images equivalent to those produced by huge apertures in space. Synthesis of apertures in the 100 to 500 meter range is discussed. Reconstruction can be performed to a visual magnitude of at least 8 for a 100 A passband in 9 hours. Data are simultaneously collected for image generation from 0.1 micron to 18 microns. In the one-dimensional mode, measurements can be made every 90 minutes (including acquisition and repointing time) for objects as faint as 19th magnitude in the visible.

  6. Active feedback regulation of a Michelson interferometer to achieve zero-background absorption measurements.

    Science.gov (United States)

    Lundin, Patrik; Guan, Zuguang; Svanberg, Sune

    2011-01-20

    An active phase-controlling scheme based on a proportional-integral-derivative-controlled piezoelectric transducer is presented with the purpose of stabilizing a quasi-zero-background absorption spectrometer. A fiber-based balanced Michelson interferometer is used, and absorption due to a gas sample in one of its arms results in an increased light signal to a detector, which otherwise, thanks to destructive interference, experiences a very low light level. With the presented approach, the sensitivity of already potent absorption measurement techniques, e.g., based on modulation, could be improved even further.

  7. Improved operation of the Michelson interferometer ECE diagnostic on DIII-D

    International Nuclear Information System (INIS)

    Austin, M.E.; Ellis, R.F.; Doane, J.L.; James, R.A.

    1996-05-01

    The measurement of accurate temperature profiles is critical for transport analysis and equilibrium reconstruction in the DIII-D tokamak. Recent refinements in the Michelson interferometer diagnostic have produced more precise electron temperature measurements from electron cyclotron emission and made them available for a wider range of discharge conditions. Replacement of a lens-relay with a low-loss corrugated waveguide transmission system resulted in an increase in throughput of 6 dB and reduction of calibration error to around 5%. The waveguide exhibits a small polarization scrambling fraction of 0.05 at the quarter wavelength frequency and very stable transmission characteristics over time. Further reduction in error has been realized through special signal processing of the calibration and plasma interferograms

  8. Optimization of a Michelson interferometer with a rotating retroreflector in opitcal design, spectral resolution, and optical throughput

    International Nuclear Information System (INIS)

    Haschberger, P.; Tank, V.

    1993-01-01

    A newly designed Michelson interferometer for Fourier spectroscopy utilizes a nutating retroreflector (cube corner mirror) to generate alterations in geometrical and optical paths. The practical optomechanical design of a Fourier-transform spectrometer incorporating a rotating retroreflector for path-length alteration is considered. (The instrument has been given the name MIROR, for Michelson Interferometer with a Rotating Retroreflector.) Two parameters of the instrument are essential: the maximum optical path difference, which yields the spectral resolution of the instrument, and the diameter of the transmitted beam, which determines the throughput and hence the achievable signal-to-noise ratio. The maximum allowable beam diameter is calculated as a function of the geometry and the orientation of the rotating retroreflector and the other optical components. The geometrical configuration and the orientation of all the optical components with respect to one another are also optimized for the maximum transmitted beam diameter when the required path difference is given. A principal investigation of different possible configurations of the optical components is presented. Then a quantitative optimization for an interferometer employing a retroreflector having a 5-in. (12.7-cm) aperture diameter requiring an optical path difference of more than 10 cm (spectral resolution better than 0.1 cm -1 ) is performed. Finally a simplified but enhanced design is described. 10 refs., 15 figs

  9. Fiber-optic Michelson interferometer fixed in a tilted tube for direction-dependent ultrasonic detection

    Science.gov (United States)

    Gang, Tingting; Hu, Manli; Qiao, Xueguang; Li, JiaCheng; Shao, Zhihua; Tong, Rongxin; Rong, Qiangzhou

    2017-01-01

    A fiber-optic interferometer is proposed and demonstrated experimentally for ultrasonic detection. The sensor consists of a compact Michelson interferometer (MI), which is fixed in a tilted-tube end-face (45°). Thin gold films are used for the reflective coatings of two arms and one of the interference arms is etched serving as the sensing arm. The spectral sideband filter technique is used to interrogate the continuous and pulse ultrasonic signals (with frequency of 300 KHz). Furthermore, because of the asymmetrical structure of the sensor, it presents strong direction-dependent ultrasonic sensitivity, such that the sensor can be considered a vector detector. The experimental results show that the sensor is highly sensitive to ultrasonic signals, and thus it can be a candidate for ultrasonic imaging of seismic physical models.

  10. A Comparison of Delayed Self-Heterodyne Interference Measurement of Laser Linewidth Using Mach-Zehnder and Michelson Interferometers

    Directory of Open Access Journals (Sweden)

    Simon Fleming

    2011-09-01

    Full Text Available Linewidth measurements of a distributed feedback (DFB fibre laser are made using delayed self heterodyne interferometry (DHSI with both Mach-Zehnder and Michelson interferometer configurations. Voigt fitting is used to extract and compare the Lorentzian and Gaussian linewidths and associated sources of noise. The respective measurements are wL (MZI = (1.6 ± 0.2 kHz and wL (MI = (1.4 ± 0.1 kHz. The Michelson with Faraday rotator mirrors gives a slightly narrower linewidth with significantly reduced error. This is explained by the unscrambling of polarisation drift using the Faraday rotator mirrors, confirmed by comparing with non-rotating standard gold coated fibre end mirrors.

  11. First Measurements of High Frequency Cross-Spectra from a Pair of Large Michelson Interferometers

    Energy Technology Data Exchange (ETDEWEB)

    Chou, Aaron S.; Gustafson, Richard; Hogan, Craig; Kamai, Brittany; Kwon, Ohkyung; Lanza, Robert; McCuller, Lee; Meyer, Stephan S.; Richardson, Jonathan; Stoughton, Chris; Tomlin, Raymond; Waldman, Samuel; Weiss, Rainer

    2016-09-01

    Measurements are reported of high frequency cross-spectra of signals from the Fermilab Holometer, a pair of co-located 39 m, high power Michelson interferometers. The instrument obtains differential position sensitivity to cross-correlated signals far exceeding any previous measurement in a broad frequency band extending to the 3.8 MHz inverse light crossing time of the apparatus. A model of universal exotic spatial shear correlations that matches the Planck scale holographic information bound of space-time position states is excluded to 4.6{\\sigma} significance.

  12. Refractive index sensor based on an abrupt taper Michelson interferometer in a single-mode fiber.

    Science.gov (United States)

    Tian, Zhaobing; Yam, Scott S-H; Loock, Hans-Peter

    2008-05-15

    A simple refractive index sensor based on a Michelson interferometer in a single-mode fiber is constructed and demonstrated. The sensor consists of a single symmetrically abrupt taper region in a short piece of single-mode fiber that is terminated by approximately 500 nm thick gold coating. The sensitivity of the new sensor is similar to that of a long-period-grating-type sensor, and its ease of fabrication offers a low-cost alternative to current sensing applications.

  13. Correction of detector nonlinearity for the balloonborne Michelson Interferometer for Passive Atmospheric Sounding.

    Science.gov (United States)

    Kleinert, Anne

    2006-01-20

    The detectors used in the cryogenic limb-emission sounder MIPAS-B2 (Michelson Interferometer for Passive Atmospheric Sounding) show a nonlinear response, which leads to radiometric errors in the calibrated spectra if the nonlinearity is not taken into account. In the case of emission measurements, the dominant error that arises from the nonlinearity is the changing detector responsivity as the incident photon load changes. The effect of the distortion of a single interferogram can be neglected. A method to characterize the variable responsivity and to correct for this effect is proposed. Furthermore, a detailed error estimation is presented.

  14. Active stabilization of a Michelson interferometer at an arbitrary phase with subnanometer resolution.

    Science.gov (United States)

    Grassani, Davide; Galli, Matteo; Bajoni, Daniele

    2014-04-15

    We report on the active stabilization of a Michelson interferometer at an arbitrary phase angle with a precision better than 1° at λ=632.8  nm, which corresponds to a precision in the optical path difference between the two arms of less than 1 nm. The stabilization method is ditherless, and the error signal is computed from the spatial shift of the interference pattern of a reference laser, measured in real-time with a CCD array detector. We discuss the usefulness of this method for nanopositioning, optical interferometry, and quantum optical experiments.

  15. Self-calibrating interferometer

    International Nuclear Information System (INIS)

    Nussmeier, T.A.

    1982-01-01

    A self-calibrating interferometer is disclosed which forms therein a pair of Michelson interferometers with one beam length of each Michelson interferometer being controlled by a common phase shifter. The transfer function measured from the phase shifter to either of a pair of detectors is sinusoidal with a full cycle for each half wavelength of phase shifter travel. The phase difference between these two sinusoidal detector outputs represents the optical phase difference between a path of known distance and a path of unknown distance

  16. Application of Young-Michelson and Brown-Twiss interferometers for determining geometric parameters of nonplanar rough objects

    International Nuclear Information System (INIS)

    Mandrosov, V I

    2008-01-01

    The possibility of using Young-Michelson and Brown-Twiss interferometers for measuring the angular dimensions and parameters of the surface shape of remote passively scattering and self-luminous nonplanar rough objects by optical radiation propagating from them is substantiated. The analysis is based on the properties of approximate transverse functions of field coherence B t and B t ' and intensity coherence B ti and B ti ' formed by the time averaging of the products of fields and intensities taken at two points of a receiving aperture (the prime denotes self-luminous objects). The averaging time is set to be much longer than the coherence time of radiation propagating from an object. It is shown that for the radiation coherence length much smaller than the depth of the visible region of the object, the functions B t and B t ' are proportional to the Fourier transform of the intensity distribution in the image of a remote object, which is the generalisation of the Van Cittert-Zernicke theorem to the case of a nonplanar object, while functions B ti and B ti ' are proportional to the squares of the modulus of the Fourier transform of this distribution. It is also shown that the recording of functions B t and B t ' with a Young-Michelson interferometer gives only the angular dimensions of the visible region of objects, whereas the recording of functions B ti and B ti ' with a Brown-Twiss interferometer allows one to find these dimensions and the radius of curvature of the object surface. (laser radiation scattering)

  17. Detecting mode hopping in single-longitudinal-mode fiber ring lasers based on an unbalanced fiber Michelson interferometer.

    Science.gov (United States)

    Ma, Mingxiang; Hu, Zhengliang; Xu, Pan; Wang, Wei; Hu, Yongming

    2012-10-20

    A method of detecting mode hopping for single-longitudinal-mode (SLM) fiber ring lasers has been proposed and experimentally demonstrated. The method that is based on an unbalanced Michelson interferometer (MI) utilizing phase generated carrier modulation instantly transforms mode-hopping dynamics into steep phase changes of the interferometer. Multiform mode hops in an SLM erbium-doped fiber ring laser with an 18.6 MHz mode spacing have been detected exactly in real-time domain and discussed in detail. Numerical results show that the MI-based method has a high testing sensitivity for identifying mode hopping, which will play a significant role in evaluating the output stability of SLM fiber lasers.

  18. Length sensing and control of a Michelson interferometer with power recycling and twin signal recycling cavities.

    Science.gov (United States)

    Gräf, Christian; Thüring, André; Vahlbruch, Henning; Danzmann, Karsten; Schnabel, Roman

    2013-03-11

    The techniques of power recycling and signal recycling have proven as key concepts to increase the sensitivity of large-scale gravitational wave detectors by independent resonant enhancement of light power and signal sidebands within the interferometer. Developing the latter concept further, twin signal recycling was proposed as an alternative to conventional detuned signal recycling. Twin signal recycling features the narrow-band sensitivity gain of conventional detuned signal recycling but furthermore facilitates the injection of squeezed states of light, increases the detector sensitivity over a wide frequency band and requires a less complex detection scheme for optimal signal readout. These benefits come at the expense of an additional recycling mirror, thus increasing the number of degrees of freedom in the interferometer which need to be controlled.In this article we describe the development of a length sensing and control scheme and its successful application to a tabletop-scale power recycled Michelson interferometer with twin signal recycling. We were able to lock the interferometer in all relevant longitudinal degrees of freedom and thus laid the foundation for further investigations of this interferometer configuration to evaluate its viability for the application in gravitational wave detectors.

  19. Optical stream-cipher-like system for image encryption based on Michelson interferometer.

    Science.gov (United States)

    Yang, Bing; Liu, Zhengjun; Wang, Bo; Zhang, Yan; Liu, Shutian

    2011-01-31

    A novel optical image encryption scheme based on interference is proposed. The original image is digitally encoded into one phase-only mask by employing an improved Gerchberg-Saxton phase retrieval algorithm together with another predefined random phase mask which serves as the encryption key. The decryption process can be implemented optically based on Michelson interferometer by using the same key. The scheme can be regarded as a stream-cipher-like encryption system, the encryption and decryption keys are the same, however the operations are different. The position coordinates and light wavelength can also be used as additional keys during the decryption. Numerical simulations have demonstrated the validity and robustness of the proposed method.

  20. Special features of Newton-type fringe formation in a diffraction interferometer

    Science.gov (United States)

    Koronkevich, Voldemar P.; Lenkova, Galina A.; Matochkin, Aleksey E.

    2006-01-01

    An interferometer with a Fresnel zone plate located in the center of curvature of a concave mirror was studied. Attention was paid to the unique features of the interference field, which has a special point at which the path difference is equal to zero, thereby allowing for the observation of Newton-type fringes in white and quasi-monochromatic light. The conditions necessary for reducing the instrumental error to values less than lambda/20 were determined. Methods for suppressing noise and destructive interference patterns were also found. Metrological tests were carried out, and they proved the possibility of using this interferometer for industrial testing of spherical and parabolic mirrors.

  1. High-temperature sensor based on an abrupt-taper Michelson interferometer in single-mode fiber.

    Science.gov (United States)

    Xu, Le; Jiang, Lan; Wang, Sumei; Li, Benye; Lu, Yongfeng

    2013-04-01

    This study proposes a high-temperature sensor based on an abrupt fiber-taper Michelson interferometer (FTMI) in single-mode fiber fabricated by a fiber-taper machine and electric-arc discharge. The proposed FTMI is applied to measure temperature and refractive index (RI). A high temperature sensitivity of 118.6 pm/°C is obtained in the temperature range of 500°C-800°C. The wavelength variation is only -0.335 nm for the maximum attenuation peak, with the external RI changed from 1.333 to 1.3902, which is desirable for high-temperature sensing to eliminate the cross sensitivity to RI.

  2. Infrared spectroscopy with a balloon borne Michelson interferometer. Pt. 2

    International Nuclear Information System (INIS)

    Moorwood, A.F.M.; Salinari, P.; Furniss, I.; Jennings, R.E.; King, K.J.

    1980-01-01

    Observations of the [O III] ionic fine structure lines at 52 μm and 88 μm, made at a resolution of 0.05 cm -1 with a balloon borne telescope and Michelson interferometer, are presented for the H II regions W 51, G33.6-0.2. M 17 S, M 17 N, NGC 6357, and NGC 6334. This is the first time that both [O III] lines have been measured simultaneously. Values for the electron density deduced from the line ratios are found to agree with the radio data, while the O ++ abundances indicate a lower excitation than expected in many cases. The [O I] line at 63 μm was also detected in NGC 6357. In addition, we report the first detection of the [N III] line at 57 μm which was observed from both sources in M 17 and gives the abundance ratio N/O = 0.13. This line was also marginally detected on W 51. (orig.)

  3. At-wavelength metrology using the moiré fringe analysis method based on a two dimensional grating interferometer

    International Nuclear Information System (INIS)

    Wang, Hongchang; Berujon, Sebastien; Pape, Ian; Rutishauser, Simon; David, Christian; Sawhney, Kawal

    2013-01-01

    A two-dimensional (2D) grating interferometer was used to perform at-wavelength metrology. A Fast Fourier Transform (FFT) of the interferograms recovers the differential X-ray beam phase in two orthogonal directions simultaneously. As an example, the X-ray wavefronts downstream from a Fresnel Zone plate were measured using the moiré fringe analysis method, which requires only a single image. The rotating shearing interferometer technique for moiré fringe analysis was extended from one dimension to two dimensions to carry out absolute wavefront metrology. In addition, the 2D moiré fringes were extrapolated using Gerchberg's method to reduce the boundary artifacts. The advantages and limitations of the phase-stepping method and the moiré fringe analysis method are also discussed. -- Highlights: ► A rapid and sensitive strip test for CPPU (forchlorfenuron) detection is reported. ► Carbon nanoparticles were used for antibody labelling. ► A common flatbed scanner was employed to the quantitate strip spots. ► The new method was successfully applied to the analysis of the field samples

  4. Michelson-Morley in Einstein's elevators

    Science.gov (United States)

    Pierce, Fred; Pierce, Ayal

    2010-02-01

    Experiments are proposed in which a Michelson-Morley interferometer is placed in Einstein's thought experiments where elevators are subjected to varied accelerated fields. Unbeknownst to the observers inside the elevators, they are placed in different circumstances: on the surface of the Earth, in free fall, in space distant from any mass, and inside a rotating space station. By use of not one, but two objects, the observer will be challenged to determine the nature and shape of the accelerated field, if any, inside the elevator. It will be demonstrated that the nature of the accelerated field can be determined easily from inside the elevator by the motion of the two objects released by the observer. It will also be shown that, for the elevator on the space station which is generating an ``artificial gravity'' field by rotation, Michelson-Morley would have the same null result as on Earth. However, the Michelson-Morley experiment is adapted so that in addition to the two horizontal arms of the interferometer (parallel to the floor of the elevator) a vertical arm is added perpendicular to the floor facing towards the ceiling. Such a vertical arm added to the Michelson-Morley experiment adds a new dimension to examining each accelerated field, including gravity. )

  5. A fringe projector-based study of the Brighter-Fatter Effect in LSST CCDs

    Science.gov (United States)

    Gilbertson, W.; Nomerotski, A.; Takacs, P.

    2017-09-01

    To achieve the goals of the Large Synoptic Survey Telescope for Dark Energy science requires a detailed understanding of CCD sensor effects. One such sensor effect is the Point Spread Function (PSF) increasing with flux, alternatively called the `Brighter-Fatter Effect.' In this work a novel approach was tested to perform the PSF measurements in the context of the Brighter-Fatter Effect employing a Michelson interferometer to project a sinusoidal fringe pattern onto the CCD. The Brighter-Fatter effect predicts that the fringe pattern should become asymmetric in the intensity pattern as the brighter peaks corresponding to a larger flux are smeared by a larger PSF. By fitting the data with a model that allows for a changing PSF, the strength of the Brighter-Fatter effect can be evaluated.

  6. Broadband measurements of electron cyclotron emission in TFTR [Tokamak Fusion Test Reactor] using a quasi-optical light collection system and a polarizing Michelson interferometer

    International Nuclear Information System (INIS)

    Stauffer, F.J.; Boyd, D.A.; Cutler, R.C.; Diesso, M.; McCarthy, M.P.; Montague, J.; Rocco, R.

    1988-04-01

    For the past three years, a Fourier transform spectrometer diagnostic system, employing a fast-scanning polarizing Michelson interferometer, has been operating on the TFTR tokamak at Princeton Plasma Physics Laboratory. It is used to measure the electron cyclotron emission spectrum over the range 2.5 to 18 cm/sup /minus/1/ (75-540 GHz) with a resolution of 0.123 cm/sup /minus/1/(3.7 GHz), at a rate of 72 spectra per second. The quasi-optical system for collecting the light and transporting it through the interferometer to the detector has been designed using the concepts of both Gaussian and geometrical optics in order to produce a system that is efficient over the entire spectral range. The commerical Michelson interferometer was custom-made for this project and is at the state of the art for this type of specialized instrument. Various pre-installation and post-installation tests of the optical system and the interferometer were performed and are reported here. An error propagation analysis of the absolute calibration process is given. Examples of electron cyclotron emission spectra measured in two polarization directions are given, and electron temperature profiles derived from each of them are compared. 34 refs., 17 figs

  7. O2 nightglow snapshots of the 1.27 μm emission at low latitudes on Mars with a static field-widened Michelson interferometer

    Science.gov (United States)

    Zhang, Rui; Ward, William E.; Zhang, Chunmin

    2017-12-01

    A static field-widened Michelson interferometer is designed to observe the atmospheric dynamics at low latitudes of Mars, targeting the 1.27 μm O2(a1Δg) nightglow, which has not yet been accurately detected due to its low intensity. To the best of our knowledge, this design is the first demonstration of implementing divided-mirror technique by refringent materials in a field-widened Michelson interferometer. Different optical path difference (OPD) in each quadrant is generated by four highly reflective pyramid-shaped prisms made of different refringent materials attached to each solid arm of Michelson interferometer. In this way four samples of interferogram are obtained simultaneously, from which the airglow volume emission rate, as well as the line-of-sight velocity and temperature of the air parcel where the emission forms can be derived in a single integration time. To achieve the best field-widening, compactness and thermal compensation, all possible combination of ten pieces of glasses were searched within the Sumita glass catalogue using a computer program and some interesting results are listed. The OPD used in this calculation concerns rays in the plane perpendicular to the sides of the prism only, other cases need further examination. This instrument's performance in measuring atmospheric dynamics is analysed, using the wind velocity uncertainty as primary criterion. Calculations show that it can measure the wind with an accuracy better than 2 m/s if the band volume emission rate of O2 nightglow is greater than 5 kph cm-3 s-1.

  8. Liquid-helium-cooled Michelson interferometer

    Science.gov (United States)

    Augason, G. C.; Young, N.

    1972-01-01

    Interferometer serves as a rocket-flight spectrometer for examination of the far infrared emission spectra of astronomical objects. The double beam interferometer is readily adapted to make spectral scans and for use as a detector of discrete line emissions.

  9. Improved operation of the Michelson interferometer electron cyclotron emission diagnostic on DIII-D

    International Nuclear Information System (INIS)

    Austin, M.E.; Ellis, R.F.; Doane, J.L.; James, R.A.

    1997-01-01

    The measurement of accurate temperature profiles is critical for transport analysis and equilibrium reconstruction in the DIII-D tokamak. Recent refinements in the Michelson interferometer diagnostic have produced more precise electron temperature measurements from electron cyclotron emission and made them available for a wider range of discharge conditions. Replacement of a lens-relay with a low-loss corrugated waveguide transmission system resulted in an increase in throughput of 6 dB and a reduction of calibration error from 15% to 5%. The waveguide exhibits a small polarization scrambling fraction of 0.05 at the quarter-wavelength frequency and very stable transmission characteristics over time. Further reduction in error was realized through special signal processing of the calibration and plasma interferograms. copyright 1997 American Institute of Physics

  10. High-speed X-ray phase tomography with Talbot interferometer and fringe scanning method

    International Nuclear Information System (INIS)

    Kibayashi, Shunsuke; Harasse, Sébastien; Yashiro, Wataru; Momose, Atsushi

    2012-01-01

    High-speed X-ray phase tomography based on the Fourier-transform method has been demonstrated with an X-ray Talbot interferometer using white synchrotron radiation. We report the experimental results of high-speed X-ray phase tomography with fringe-scanning method instead of Fourier-transform method to improve spatial resolution without a considerable increase of scan time. To apply fringe-scanning method to high speed tomography, we tested a scan that is a synchronous combination of one-way continuous movements of the sample rotation and the grating displacement. When this scanning method was combined with X-ray phase tomography, we were able to obtain a scan time of 5 s. A comparison of the image quality derived with the conventional approach and with the proposed approach using the fringe-scanning method showed that the latter had better spatial resolution.

  11. 100 years since Michelson and Morley - the quest for the ultimate interferometer

    International Nuclear Information System (INIS)

    Bachor, H.A.; McClelland, D.E.

    1989-01-01

    This paper summarise some of the achievements of optical interferometry in its 100 years of existence. It is shown how over the decades, developments in optics, lasers, electronics and quantum mechanics have led to dramatic improvements in sensitivity, with the most recent developments aiming at a δL/L of 10 -12 . In addition, digital image processing and laser stabilisation techniques were combined to analyse optical surfaces with a resolution of 1/500 of a fringe. Some of interferometer applications are discussed and these include radio astronomy, laser gyroscopes, the visualisation of flows and the diagnostic of laboratory plasmas. 18 refs., 2 figs

  12. Investigation of shear distance in Michelson interferometer-based shearography for mechanical characterization

    International Nuclear Information System (INIS)

    Lee, Jung-Ryul; Yoon, Dong-Jin; Kim, Jung-Seok; Vautrin, Alain

    2008-01-01

    Shearography is a growing industrial field in both quantitative mechanical characterization and relatively qualitative non-destructive testing. In shearography, shear distance is the most important parameter to control measurement performances. In this paper, the role of the shear distance is systematically investigated, focusing on the application of full-field mechanical characterization. A modified Michelson interferometer is considered as the shearing device, which is most commonly adopted for mechanical characterization applications because it enables easy and precise shearing and phase shifting. This paper also includes theoretical and experimental investigations of the relationship between shear distance and performance issues such as the immeasurable zone in the target with discontinuity, signal-to-noise ratio, sensitivity and shear distortion. In addition, this study is verified with actual shearographic results and a phase-shifting grid method capable of full-field displacement evaluation in the submicrometer regime

  13. Hyperfine spectrum measurement of an optically pumped far-infrared laser with a Michelson interferometer

    International Nuclear Information System (INIS)

    Zuo, Z G; Ling, F R; Wang, P; Liu, J S; Yao, J Q; Weng, C X

    2013-01-01

    In this letter, we present a Michelson interferometer for the hyperfine spectrum measurement of an optically pumped far-infrared laser with a highest frequency resolution of 3–5 GHz. CH 3 OH gas with a purity of 99.9%, is pumped by the CO 2 9P36 and 9R10 laser lines to generate terahertz lasers with frequencies of 2.52 and 3.11 THz, respectively. Moreover, except for the center frequency, which is in good agreement with theoretical work, some additional frequencies on both sides of the center frequency are obtained at a frequency interval of 0.15 THz. Meanwhile, the mechanism behind the observed experimental results is also investigated. (letter)

  14. On the importance of the Michelson-Morley experiment

    International Nuclear Information System (INIS)

    Strel'tsov, V.N.

    1992-01-01

    The opinion of an important role of the Michelson-Morley experiment in the establishment of the pronciple oof the light velocity constancy is expressed. It is stressed that the used of radar length for the treatment of the Michelson-Morley experiment leads to the elongation formulas for the longitudinal arm of an interferometer. 24 refs

  15. Performance of a Rapid-Scan Vacuum Michelson Interferometer at the NSLS

    International Nuclear Information System (INIS)

    Brierly, P.; Dumas, P.; Smith, M.; Williams, G.P.

    2001-01-01

    A commercial Nicolet Magna series rapid-scan Michelson Fourier Transform Infrared (FTIR) was installed in a vacuum housing and integrated into the U4IR beamline at the National Synchrotron Light Source at Brookhaven National Laboratory. The frequency reference laser was mounted outside vacuum, but the moving mirror mechanism and the dynamic alignment system for the fixed mirror were in vacuum. The performance of the instrument was measured in the usual way by measuring the repeatability of data collected under specific conditions of aperture, resolution and mirror scanning velocity. We briefly discuss the beamline design, to put the interferometer in context, then present signal to noise data which we discuss in terms of both instrument performance and also storage ring stability. Under optimal conditions, the instrument has a reproducibility of 0.01% in 1 minute of measuring time at a resolution of 2 cmss, -1 , over a range from 100-3000 cm -1

  16. The Explanation of Michelson's Experiment

    International Nuclear Information System (INIS)

    Klinaku, Shukri

    2010-01-01

    In this paper we will prove that the Lorentz factor doesn't exist on the relative motion. In fact this factor is the result of a wrong calculation of Michelson. His mistake was approved by Lorentz and other physicists, including Einstein. Michelson in order to implement his idea with his interferometer in 1881, made the following mistake: he made the calculation according to the only principle of relativity which was known by physics--the Galileo principle, but he didn't faithfully apply this principle. In this paper, the principle of Galileo will be implemented exactly to Michelson's experiment and the result will show us that physics doesn't need the postulates of the year 1905.

  17. Studies of Gravity Waves Using Michelson Interferometer Measurements of OH (3-1) Bands

    Science.gov (United States)

    Won, Young-In; Cho, Young-Min; Lee, Bang Yong; Kim, J.

    2001-06-01

    As part of a long-term program for polar upper atmospheric studies, temperatures and intensities of the OH (3-1) bands were derived from spectrometric observations of airglow emissions over King Sejong station (62.22o S, 301.25o E). These measurements were made with a Michelson interferometer to cover wavelength regions between 1000 nm and 2000 nm. A spectral analysis was performed to individual nights of data to acquire information on the waves in the upper mesosphere/lower thermosphere. It is assumed that the measured fluctuations in the intensity and temperature of the OH (3-1) airglow were caused by gravity waves propagating through the emission layer. Correlation of intensity and temperature variation revealed oscillations with periods ranging from 2 to 9 hours. We also calculated Krassovsky's parameter and compared with published values.

  18. A Michelson interferometer system for testing the stability of a piezo-electric actuator intended for use in space

    International Nuclear Information System (INIS)

    Aplin, K L; Middleton, K F

    2007-01-01

    The Laser Interferometer Space Antenna (LISA) experiment will search for gravitational waves generated by cataclysmic events far back in astronomical history. LISA is an interferometer formed by three spacecraft positioned five million km apart, and to observe gravitational waves, it must monitor test mass positions with picometre level resolution. One of the numerous technological challenges is to identify an actuator with appropriate accuracy, precision and stability for positioning of the optical fibres used to deliver LISA's laser sources. We have developed a Michelson interferometer system to determine the temporal and thermal stability of candidate actuators, with an emphasis on characterisation in the milliHertz frequency range required for gravitational wave detection in space. This paper describes the interferometer data logging and calibration and presents preliminary results in the form of a 'noise spectrum' generated from the small perturbation of a nominally static mirror. The maximum displacement of the mirror was ∼50 nm with sub-Hz noise levels of 0.1-1 nm√Hz. This is within the LISA noise specification, and confirms that the apparatus is stable enough for the characterisation of the actuator

  19. Albert Abraham Michelson

    Indian Academy of Sciences (India)

    Some experiments change the face of a subject, and some experiments do that many times over. Albert Michelson built his interferometer in order to determine the effect of Earth's rotation on the speed of light. The null result supported the crucial assumption in Einstein's special theory of relativity and was the final nail in the ...

  20. Structural-Thermal-Optical-Performance (STOP) Model Development and Analysis of a Field-widened Michelson Interferometer

    Science.gov (United States)

    Scola, Salvatore J.; Osmundsen, James F.; Murchison, Luke S.; Davis, Warren T.; Fody, Joshua M.; Boyer, Charles M.; Cook, Anthony L.; Hostetler, Chris A.; Seaman, Shane T.; Miller, Ian J.; hide

    2014-01-01

    An integrated Structural-Thermal-Optical-Performance (STOP) model was developed for a field-widened Michelson interferometer which is being built and tested for the High Spectral Resolution Lidar (HSRL) project at NASA Langley Research Center (LaRC). The performance of the interferometer is highly sensitive to thermal expansion, changes in refractive index with temperature, temperature gradients, and deformation due to mounting stresses. Hand calculations can only predict system performance for uniform temperature changes, under the assumption that coefficient of thermal expansion (CTE) mismatch effects are negligible. An integrated STOP model was developed to investigate the effects of design modifications on the performance of the interferometer in detail, including CTE mismatch, and other three- dimensional effects. The model will be used to improve the design for a future spaceflight version of the interferometer. The STOP model was developed using the Comet SimApp'TM' Authoring Workspace which performs automated integration between Pro-Engineer®, Thermal Desktop®, MSC Nastran'TM', SigFit'TM', Code V'TM', and MATLAB®. This is the first flight project for which LaRC has utilized Comet, and it allows a larger trade space to be studied in a shorter time than would be possible in a traditional STOP analysis. This paper describes the development of the STOP model, presents a comparison of STOP results for simple cases with hand calculations, and presents results of the correlation effort to bench-top testing of the interferometer. A trade study conducted with the STOP model which demonstrates a few simple design changes that can improve the performance seen in the lab is also presented.

  1. ECE diagnostic for the TARA tandem mirror machine using a fast-scanning Michelson interferometer

    International Nuclear Information System (INIS)

    Guharay, S.K.; Boyd, D.A.; Ellis, R.F.

    1986-01-01

    This ECE (electron cyclotron emission) diagnostic utilizes a fast-scanning Michelson interferometer to determine two parameters, the temperature and the loss cone angle, of the distribution function of the hot electrons (Tapprox. >100 keV) generated in the axisymmetric plug plasma of the TARA tandem mirror device. The radiation transport system employs a lens relay and a low-pass grating filter in order to transmit the synchrotron radiation over a spectral range of 2.9--18.6 cm -1 . This enables us to study the emitted radiation spectrum up to the 40th harmonic of the electron--cyclotron frequency in the plug plasma (B = 5 kG). Details of the design principles and the development of the diagnostic at TARA will be presented

  2. Measurements of refractive indices and thermo-optical coefficients using a white-light Michelson interferometer.

    Science.gov (United States)

    Rocha, A C P; Silva, J R; Lima, S M; Nunes, L A O; Andrade, L H C

    2016-08-20

    A dispersive white-light Michelson interferometer was used to determine the wavelength dependence of the refractive index (n) in the visible range from 425 to 775 nm and the thermo-optical coefficient (dn/dT) of fused silica (FS) and borosilicate glass (BK7). For FS, the values obtained for n and dn/dT at 546 nm were 1.46079 and 11.3×10-6  K-1, respectively, while the values for BK7 glass were 1.51825 and 2.2×10-6  K-1, respectively, which is in good agreement with the literature. The accuracy of the methodology used for n was almost 10-6, enabling precise spectroscopic characterization of materials across a wide spectral range.

  3. Broadband micro-Michelson interferometer with multi-optical-path beating using a sphered-end hollow fiber.

    Science.gov (United States)

    Chen, Nan-Kuang; Lu, Kuan-Yi; Shy, Jow-Tsong; Lin, Chinlon

    2011-06-01

    We demonstrate a high-sensitivity broadband (1250-1650 nm) fiber micro-Michelson interferometer using a single-mode fiber end-spliced with a sphered-end hollow-core fiber. The hollow core is slightly smaller than the solid core of a single-mode fiber, so the fractional power of the core mode is converted into cladding modes. The excited cladding modes propagate at distinct optical paths along the hollow-core fiber and have individual foci outside the spherical lens. The reflected core mode, generated at the solid core-air interface, and the reflected cladding modes, generated at external material, interfere with each other to produce beating in the interference signals. © 2011 Optical Society of America

  4. Polarization Beam Splitter Based on a Self-Collimation Michelson Interferometer in a Silicon Photonic Crystal

    International Nuclear Information System (INIS)

    Chen Xi-Yao; Lin Gui-Min; Li Jun-Jun; Xu Xiao-Fu; Jiang Jun-Zhen; Qiang Ze-Xuan; Qiu Yi-Shen; Li Hui

    2012-01-01

    A polarization beam splitter based on a self-collimation Michelson interferometer (SMI) in a hole-type silicon photonic crystal is proposed and numerically demonstrated. Utilizing the polarization dependence of the transmission spectra of the SMI and polarization peak matching method, the SMI can work as a polarization beam splitter (PBS) by selecting an appropriate path length difference in the structure. Based on its novel polarization beam splitting mechanics, the polarization extinction ratios (PERs) for TM and TE modes are as high as 18.4 dB and 24.3 dB, respectively. Since its dimensions are only several operating wavelengths, the PBS may have practical applications in photonic integrated circuits. (fundamental areas of phenomenology(including applications))

  5. Studies of Gravity Waves Using Michelson Interferometer Measurements of OH (3-1 Bands

    Directory of Open Access Journals (Sweden)

    Young-In Won

    2001-06-01

    Full Text Available As part of a long-term program for polar upper atmospheric studies, temperatures and intensities of the OH (3-1 bands were derived from spectrometric observations of airglow emissions over King Sejong station (62.22o S, 301.25o E. These measurements were made with a Michelson interferometer to cover wavelength regions between 1000 nm and 2000 nm. A spectral analysis was performed to individual nights of data to acquire information on the waves in the upper mesosphere/lower thermosphere. It is assumed that the measured fluctuations in the intensity and temperature of the OH (3-1 airglow were caused by gravity waves propagating through the emission layer. Correlation of intensity and temperature variation revealed oscillations with periods ranging from 2 to 9 hours. We also calculated Krassovsky's parameter and compared with published values.

  6. Dense plasmas interferometry using an X-UV laser. Development of an X-UV Michelson interferometer at 13.9 nm

    International Nuclear Information System (INIS)

    Hubert, S.

    2001-01-01

    After having recalled some aspects related to the physics of plasmas produced by interaction between laser and matter, and related to inertial confinement fusion or ICF (discussion of laser energy absorption, X conversion, parametric and hydrodynamic instabilities, and so on), this research thesis presents various techniques used for plasma diagnosis in order to justify the use of interferometry for the investigation of the electronic density distribution of these plasmas. The physical principle of this diagnosis technique is described and two types of X-UV interferometer are presented, one of them being chosen as more suitable for the study of ICF-type plasmas. The author then describes and reports the experimental investigation performed with a two-mirror Fresnel interferometer and a 21.2 nm zinc X-UV laser: description of the interferometer operation and characteristics, of the specifically designed image system, discussion of plasma interferogram simulations. Then, he reports the development of a Michelson-type X-UV interferometer at 13.9 nm. The operation principle is recalled, and the preliminary modelling phase is reported. The imaging system is presented and results of the interferogram modelling phase are presented [fr

  7. Polarization-dependent in-line quasi-Michelson interferometer based on PM-PCF reflection.

    Science.gov (United States)

    Du, Yanying; Qiao, Xueguang; Rong, Qiangzhou; Zhang, Jing; Feng, Dingyi; Wang, Ruohui; Sun, Hao; Hu, Manli; Feng, Zhongyao

    2013-05-20

    An in-line fiber quasi-Michelson interferometer (IFQMI) working on reflection is proposed and experimentally demonstrated. The sensing head is fabricated by splicing a section of polarization-maintaining photonic crystal fiber (PM-PCF) with a lead-in single mode fiber (SMF). Some cladding modes are excited into the PM-PCF via the mismatch-core splicing interface between PM-PCF and SMF. Besides, two orthogonal polarized-modes are formed due to the inherent multiholes cladding structure of the PM-PCF. A well-defined interference pattern is obtained as the result of cladding-orthogonal modes interference. The IFQMI with 20 cm long PM-PCF is proposed for strain and torsion measurements. A strain sensitivity of -1.3 pm/με and a torsion sensitivity of -19.17 pm/deg are obtained, respectively. The proposed device with 10 cm long PM-PCF exhibits a considered temperature sensitivity of 9.9 pm/°C. The IFQMI has a compact structure and small size, making it a good candidate for multiparameter measurements.

  8. Modeling and analysis of laser active interference optical path

    Science.gov (United States)

    Shan, Cong-miao; Sun, Hua-yan; Zhao, Yan-zhong; Chen, Jian-biao; Ren, Jian-ying

    2017-10-01

    By using the geometrical optics and physical optics method, the models of wedge plate interference optical path, Michelson interferometer and Mach Zehnder interferometer thus three different active interference pattern are built. The optical path difference (OPD) launched by different interference patterns, fringe spacing and contrast expression have been derived. The results show that far field interference peak intensity of the wedge plate interference is small, so the detection distance is limited, Michelson interferometer with low contrast affects the performance of detection system, Mach Zehnder interferometer has greater advantages in peak intensity, the variable range of interference fringe spacing and contrast ratio. The results of this study are useful for the theoretical research and practical application of laser active interference detection.

  9. Measurements of femtosecond pulse temporal profile by means of a Michelson interferometer with a Schottky junction.

    Science.gov (United States)

    Ling, Yan; Lu, Fang

    2006-12-20

    We introduce a new method for femtosecond pulse shape measurement. The interference of two pulses is employed rather than the second-harmonic generation (SHG). Usually, the measurements of the femtosecond pulse is realized by an interferometer in combination with a nonlinear optical material, while the measurement that we describe is realized by means of a Michelson interferometer with a Schottky junction. Only a metal-semiconductor junction (Schottky junction) is needed, and neither the nonlinear optical material nor a photodetector is included. The two-photon absorption arises when the light is strong enough, while there is only a one-photon absorption when the light is weak. And the calculations are in good agreement with the experimental results. In principle, the new technique could be used for the measuring of pulses with any duration and with very low power. Unlike the SHG scheme, in the new method the quality of optics, mechanics, and other elements of the scheme are not essential, and the measurement is easily realized, but the results are quite precise and very sensitive to the light.

  10. Stable fiber interferometer

    International Nuclear Information System (INIS)

    Izmajlov, G.N.; Nikolaev, F.A.; Ozolin, V.V.; Grigor'yants, V.V.; Chamorovskij, Yu.K.

    1989-01-01

    The problem of construction the long-base Michelson interferometer for gravitational wave detection is discussed. Possible sources of noise and instability are considered. It is shown that evacuation of fiber interferometer, the winding of its arms on the glass ceramic bases, stabilization of radiation source frequency and seismic isolation of the base allow one to reduce its instability to the level, typical of mirror interferometer with the comparable optical base. 10 refs.; 2 figs

  11. Spatio-temporal coherence of free-electron laser radiation in the extreme ultraviolet determined by a Michelson interferometer

    Energy Technology Data Exchange (ETDEWEB)

    Hilbert, V.; Rödel, C.; Zastrau, U., E-mail: ulf.zastrau@uni-jena.de [Institut für Optik und Quantenelektronik, Friedrich-Schiller-Universität, Max-Wien-Platz 1, 07743 Jena (Germany); Brenner, G.; Düsterer, S.; Dziarzhytski, S.; Harmand, M.; Przystawik, A.; Redlin, H.; Toleikis, S. [Deutsches Elektronen-Synchrotron DESY, Notkestrasse 85, 22607 Hamburg (Germany); Döppner, T.; Ma, T. [Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore, California 94550 (United States); Fletcher, L. [Department of Physics, University of California, Berkeley, California 94720 (United States); Förster, E. [Institut für Optik und Quantenelektronik, Friedrich-Schiller-Universität, Max-Wien-Platz 1, 07743 Jena (Germany); Helmholtz-Institut Jena, Fröbelstieg 3, 07743 Jena (Germany); Glenzer, S. H.; Lee, H. J. [SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, California 94025 (United States); Hartley, N. J. [Department of Physics, Clarendon Laboratory, University of Oxford, Parks Road, Oxford OX1 3PU (United Kingdom); Kazak, L.; Komar, D.; Skruszewicz, S. [Institut für Physik, Universität Rostock, 18051 Rostock (Germany); and others

    2014-09-08

    A key feature of extreme ultraviolet (XUV) radiation from free-electron lasers (FELs) is its spatial and temporal coherence. We measured the spatio-temporal coherence properties of monochromatized FEL pulses at 13.5 nm using a Michelson interferometer. A temporal coherence time of (59±8) fs has been determined, which is in good agreement with the spectral bandwidth given by the monochromator. Moreover, the spatial coherence in vertical direction amounts to about 15% of the beam diameter and about 12% in horizontal direction. The feasibility of measuring spatio-temporal coherence properties of XUV FEL radiation using interferometric techniques advances machine operation and experimental studies significantly.

  12. Laser phase and frequency noise measurement by Michelson interferometer composed of a 3 × 3 optical fiber coupler.

    Science.gov (United States)

    Xu, Dan; Yang, Fei; Chen, Dijun; Wei, Fang; Cai, Haiwen; Fang, Zujie; Qu, Ronghui

    2015-08-24

    A laser phase and frequency noise measurement method by an unbalanced Michelson interferometer composed of a 3 × 3 optical fiber coupler is proposed. The relations and differences of the power spectral density (PSD) of differential phase and frequency fluctuation, PSD of instantaneous phase and frequency fluctuation, phase noise and linewidth are derived strictly and discussed carefully. The method obtains the noise features of a narrow linewidth laser conveniently without any specific assumptions or noise models. The technique is also used to characterize the noise features of a narrow linewidth external-cavity semiconductor laser, which confirms the correction and robustness of the method.

  13. A study of far-infrared Michelson interferometry based on fast plasma scanning

    International Nuclear Information System (INIS)

    Bartlett, D.V.; Hewitt, G.L.; Robinson, L.C.; Tait, G.D.

    1976-02-01

    Fast far-infrared multiplex spectroscopy based on a plasma-scanned Michelson interferometer is studied. Our experiments show that the interferometer has sub-millisecond time response and high spectral resolving power. In addition to a description of the experimental performance of the interferometer, we develop and discuss two different methods of interferogram inversion. (author)

  14. A study of far-infrared Michelson interferometry based on fast plasma scanning

    International Nuclear Information System (INIS)

    Bartlett, D.V.; Hewitt, R.G.L.; Robinson, L.C.; Tait, G.D.

    1977-01-01

    Fast far infrared (FIR) muliplex spectroscopy based on a plasma-scanned Michelson interferometer is studied. Experiments show that the interferometer has sub-millisecond time response and high spectral resolving power. In addition to the description of the experimental performance of the interferometer, two different methods of interferogram inversion are developed and discussed. (author)

  15. Japanese large-scale interferometers

    CERN Document Server

    Kuroda, K; Miyoki, S; Ishizuka, H; Taylor, C T; Yamamoto, K; Miyakawa, O; Fujimoto, M K; Kawamura, S; Takahashi, R; Yamazaki, T; Arai, K; Tatsumi, D; Ueda, A; Fukushima, M; Sato, S; Shintomi, T; Yamamoto, A; Suzuki, T; Saitô, Y; Haruyama, T; Sato, N; Higashi, Y; Uchiyama, T; Tomaru, T; Tsubono, K; Ando, M; Takamori, A; Numata, K; Ueda, K I; Yoneda, H; Nakagawa, K; Musha, M; Mio, N; Moriwaki, S; Somiya, K; Araya, A; Kanda, N; Telada, S; Sasaki, M; Tagoshi, H; Nakamura, T; Tanaka, T; Ohara, K

    2002-01-01

    The objective of the TAMA 300 interferometer was to develop advanced technologies for kilometre scale interferometers and to observe gravitational wave events in nearby galaxies. It was designed as a power-recycled Fabry-Perot-Michelson interferometer and was intended as a step towards a final interferometer in Japan. The present successful status of TAMA is presented. TAMA forms a basis for LCGT (large-scale cryogenic gravitational wave telescope), a 3 km scale cryogenic interferometer to be built in the Kamioka mine in Japan, implementing cryogenic mirror techniques. The plan of LCGT is schematically described along with its associated R and D.

  16. Improved double-pass michelson interferometer

    Science.gov (United States)

    Schindler, R. A.

    1978-01-01

    Interferometer design separates beams by offsetting centerlines of cat's-eye retroreflectors vertically rather than horizontally. Since beam splitter is insensitive to minimum-thickness condition in this geometry, relatively-low-cost, optically flat plate can be used.

  17. Composite cavity based fiber optic Fabry–Perot strain sensors demodulated by an unbalanced fiber optic Michelson interferometer with an electrical scanning mirror

    International Nuclear Information System (INIS)

    Zhang, Jianzhong; Yang, Jun; Sun, Weimin; Yuan, Libo; Jin, Wencai; Peng, G D

    2008-01-01

    A composite cavity based fiber optic Fabry–Perot strain sensor system, interrogated by a white light source and demodulated by an unbalanced fiber optic Michelson interferometer with an electrical scanning mirror, is proposed and demonstrated. Comparing with the traditional extrinsic fiber optic Fabry–Perot strain sensor, the potential multiplexing capability and the dynamic measurement range are improved simultaneously. At the same time, the measurement stability of the electrical scanning mirror system is improved by the self-referenced signal of the sensor structure

  18. In-fiber quasi-Michelson interferometer with a core-cladding-mode fiber end-face mirror.

    Science.gov (United States)

    Rong, Qiangzhou; Qiao, Xueguang; Du, Yanying; Feng, Dingyi; Wang, Ruohui; Ma, Yue; Sun, Hao; Hu, Manli; Feng, Zhongyao

    2013-03-01

    An in-fiber quasi-Michelson interferometer working on reflection is proposed and experimentally demonstrated. The device consists of a short section of multimode fiber (MMF) followed by a single-mode fiber (SMF) whose end face is terminated by a thick silver film. The MMF excites cladding modes into downstream SMF via the mismatched-core splicing interface. The core-cladding modes are reflected back by the silver film and recoupled to the core of lead-in SMF through the MMF. A well-defined interference pattern is obtained as the result of core-cladding mode interference. A configuration with a 40 mm pigtail SMF at a wavelength of 1528 nm exhibits a water level sensitivity of -49.8 pm/mm and a liquid refractive index sensitivity of -574.6 (pm/mm)/RIU (refractive index unit). In addition, the selected dip provides a considered temperature sensitivity of -61.26 pm/°C and a high displacement sensitivity of -1018.6 pm/mm.

  19. The variable finesse locking technique

    International Nuclear Information System (INIS)

    Acernese, F; Al-Shourbagy, M

    2006-01-01

    Virgo is a power recycled Michelson interferometer, with 3 km long Fabry-Perot cavities in the arms. The locking of the interferometer has been obtained with an original lock acquisition technique. The main idea is to lock the instrument away from its working point. Lock is obtained by misaligning the power recycling mirror and detuning the Michelson from the dark fringe. In this way, a good fraction of light escapes through the antisymmetric port and the power build-up inside the recycling cavity is extremely low. The benefit is that all the degrees of freedom are controlled when they are almost decoupled, and the linewidth of the recycling cavity is large. The interferometer is then adiabatically brought on to the dark fringe. This technique is referred to as variable finesse, since the recycling cavity is considered as a variable finesse Fabry-Perot. This technique has been widely tested and allows us to reach the dark fringe in few minutes, in an essentially deterministic way

  20. Effect of input spectrum on the spectral switch characteristics in a white-light Michelson interferometer.

    Science.gov (United States)

    Brundavanam, Maruthi M; Viswanathan, Nirmal K; Rao, D Narayana

    2009-12-01

    We report here a detailed experimental study to demonstrate the effect of source spectral characteristics such as spectral bandwidth (Deltalambda), peak wavelength (lambda(0)), and shape of the spectrum on the spectral shifts and spectral switches measured due to temporal correlation in a white-light Michelson interferometer operated in the spectral domain. Behavior of the spectral switch characteristics such as the switch position, switch amplitude, and switch symmetry are discussed in detail as a function of optical path difference between the interfering beams. The experimental results are compared with numerical calculations carried out using interference law in the spectral domain with modified source spectral characteristics. On the basis of our results we feel that our study is of critical importance in the selection of source spectral characteristics to further improve the longitudinal resolution or the measurement sensitivity in spectral-domain optical coherence tomography and microscopy.

  1. Reconfiguration of the multiwavelength operation of optical fiber ring lasers by the modifiable intra-cavity induced losses of an in-fiber tip probe modal Michelson interferometer

    Science.gov (United States)

    Salceda-Delgado, G.; Martinez-Rios, A.; Sierra-Hernandez, J. M.; Rodríguez-Carreón, V. C.; Toral-Acosta, D.; Selvas-Aguilar, R.; Álvarez-Tamayo, R. I.; Castillo-Guzman, A. A.; Rojas-Laguna, R.

    2018-03-01

    A straightforward and versatile method for switching from single to different multiwavelength laser emission in ring cavity fiber lasers is proposed and demonstrated experimentally. The method is based on using the changeable interference pattern from an optical fiber modal Michelson interferometer as a wavelength selective filter into the ring cavity laser. The interferometer is constructed using a bi-conical tapered fiber and a single-mode fiber segment, with these being spliced together to form an optical fiber tip probe. When the length of the single-mode fiber piece is modified, the phase difference between the interfering modes of the interferometer causes a change in the interferometer free spectral range. As a consequence, the laser intra-cavity losses lead to gain competition, which allows us to adjust the number of simultaneously generated laser lines. A multiwavelength reconfiguration of the laser from one up to a maximum of eight emission lines was obtained, with a maximum SNR of around 47 dBm.

  2. Early Type Stars as Calibrators for Ground-Based Interferometry

    National Research Council Canada - National Science Library

    Yoon, Jinmi; Peterson, Deane M; Amstrong, Thomas; Clark III, James H; Gilbreath, Charmaine; Pauls, Thomas; Schmitt, Henrique R

    2006-01-01

    Visibility measurements with Michelson interferometers, particularly the measurement of fringe contrast, are affected by various atmospheric and instrumental effects, all of which reduce the measured contrast...

  3. Distance measurement using frequency scanning interferometry with mode-hoped laser

    Science.gov (United States)

    Medhat, M.; Sobee, M.; Hussein, H. M.; Terra, O.

    2016-06-01

    In this paper, frequency scanning interferometry is implemented to measure distances up to 5 m absolutely. The setup consists of a Michelson interferometer, an external cavity tunable diode laser, and an ultra-low expansion (ULE) Fabry-Pérot (FP) cavity to measure the frequency scanning range. The distance is measured by acquiring simultaneously the interference fringes from, the Michelson and the FP interferometers, while scanning the laser frequency. An online fringe processing technique is developed to calculate the distance from the fringe ratio while removing the parts result from the laser mode-hops without significantly affecting the measurement accuracy. This fringe processing method enables accurate distance measurements up to 5 m with measurements repeatability ±3.9×10-6 L. An accurate translation stage is used to find the FP cavity free-spectral-range and therefore allow accurate measurement. Finally, the setup is applied for the short distance calibration of a laser distance meter (LDM).

  4. Observations of OH(3,1) airglow emission using a Michelson interferometer at 62° S

    Science.gov (United States)

    Won, Young-In; Cho, Young-Min; Niciejewski, Rick J.; Kim, Jhoon

    A Michelson interferometer was used to observe the hydroxyl (OH) emission in the upper mesosphere at the King Sejong Station (62.22° S, 301.25° E), Antarctica. The instrument was installed in February 1999 and has been in routine operation since then. An intensive operational effort has resulted in a substantial data set between April and June, 1999. A spectral analysis was performed on individual data to examine the information of dominant waves. A harmonic analysis was also carried out on the monthly average data to investigate the characteristics of the major low frequency oscillations. The 12-hr temperature oscillations exhibit a striking agreement with a theoretical tidal model, supporting the tidal (migrating) origin. The 8-hr wave is found to be persistent and dominant, reflecting its major role in the upper mesospheric dynamics at the given latitude. The 6-hr oscillation is observed only in May with its value close to the prediction for zonally symmetric tides.

  5. Interference of Light in a Michelson-Morley Interferometer: A Quantum Optical Approach

    Directory of Open Access Journals (Sweden)

    Ø. Langangen

    2012-01-01

    Full Text Available The temporal coherence interference properties of light as revealed by single detector intensity measurements in a Michelson-Morley interferometer (MMI is often described in terms of classical optics. We show, in a pedagogical manner, how such features of light also can be understood in terms of a more general quantum-optics framework. If a thermal reference source is used in the MMI local oscillator port in combination with a thermal source in the signal port, the interference pattern revealed by single detector intensity measurements shows a distinctive dependence on the differences in the temperature of the two sources. A related method has actually been used to perform high-precision measurements of the cosmic microwave background radiation. The general quantum-optics framework allows us to consider any initial quantum state. As an example, we consider the interference of single photons as a tool to determine the peak angular-frequency of a single-photon pulse interfering with a single-photon reference pulse. A similar consideration for laser pulses, in terms of coherent states, leads to a different response in the detector. The MMI experimental setup is therefore an example of an optical device where one, in terms of intensity measurements, can exhibit the difference between classical and quantum-mechanical light.

  6. Michelson mode selector for spectral range stabilization in a self-sweeping fiber laser.

    Science.gov (United States)

    Tkachenko, A Yu; Vladimirskaya, A D; Lobach, I A; Kablukov, S I

    2018-04-01

    We report on spectral range stabilization in a self-sweeping laser by adding a narrowband fiber Bragg grating (FBG) to the output mirror in the Michelson configuration. The effects of FBG reflectivity and optical path difference in the Michelson interferometer on the laser spectral dynamics are investigated. Optimization of the interferometer allows us to demonstrate broadband (over 16 nm) self-sweeping operation and reduction of the start and stop wavelength fluctuations by two orders and one order of magnitude (∼100 and 15 times) for start and stop bounds, respectively (down to several picometers). The proposed approaches significantly improve quality of the spectral dynamics and facilitate application of the self-sweeping lasers.

  7. Generation of sinusoidal fringes with a holographic phase grating and a phase-only spatial light modulator

    International Nuclear Information System (INIS)

    Berberova, Natalia; Stoykova, Elena; Sainov, Ventseslav

    2012-01-01

    A variety of pattern projection methods for the three-dimensional capture of objects is based on the generation of purely sinusoidal fringes. This is not an easy task, especially when a portable non-interferometric system for outdoor usage is required. The use of phase gratings with coherent illumination as a possible solution has the advantage of providing good stability and a large measurement volume. In this work, we analyze the quality of fringes projected with two sinusoidal phase gratings. The first grating is recorded on a silver-halide holographic plate by means of a Michelson interferometer. The spatial resolution of the silver-halide material used is greater than 6000 lines per millimeter, and the recorded grating is practically analogous to a smooth variation of the phase profile. The second grating is formed as a sinusoidal phase variation on a liquid crystal-on-silicon phase-only reflective display with a resolution of 1920×1080 pixels, a pixel pitch of 8 μm and 256 phase levels. The frequency content of the fringes projected with both gratings is analyzed and compared on the basis of the calculated Fresnel diffraction pattern, taking into account that the sinusoidal phase distribution in the case of a spatial light modulator is both sampled and quantized. Experimental fringe patterns projected using both gratings are also provided.

  8. SAMSI: An orbiting spatial interferometer for micro-arc second astronomical observations. [Spacecraft Array for Michelson Spatial Interferometry (SAMSI)

    Science.gov (United States)

    Stachnik, R. V.; Gezari, D. Y.

    1985-01-01

    The concept and performance of (SAMSI) Spacecraft Array for Michelson Spatial Interferometry, an orbiting spatial interferometer comprised of three free-flying spacecraft, two collector telescopes and a central mixing station are described. In the one-dimensional interferometry mode orbits exist which provide natural scanning of the baseline. These orbits place extremely small demands on thrusters and fuel consumption. Resolution of 0.00001 arcsecond and magnitude limits of mv = 15 to 20 are achievable in a single orbit. In the imaging mode, SAMSI could synthesize images equivalent to those produced by equal diameter filled apertures in space, making use of the fuel resupply capability of a space station. Simulations indicate that image reconstruction can be performed with milliarcsecond resolution to a visual magnitude 12 in 12 hr of spiral scanning integration time.

  9. Michelson Interferometer for Global High-Resolution Thermospheric Imaging (MIGHTI): Instrument Design and Calibration

    Science.gov (United States)

    Englert, Christoph R.; Harlander, John M.; Brown, Charles M.; Marr, Kenneth D.; Miller, Ian J.; Stump, J. Eloise; Hancock, Jed; Peterson, James Q.; Kumler, Jay; Morrow, William H.; Mooney, Thomas A.; Ellis, Scott; Mende, Stephen B.; Harris, Stewart E.; Stevens, Michael H.; Makela, Jonathan J.; Harding, Brian J.; Immel, Thomas J.

    2017-10-01

    The Michelson Interferometer for Global High-resolution Thermospheric Imaging (MIGHTI) instrument was built for launch and operation on the NASA Ionospheric Connection Explorer (ICON) mission. The instrument was designed to measure thermospheric horizontal wind velocity profiles and thermospheric temperature in altitude regions between 90 km and 300 km, during day and night. For the wind measurements it uses two perpendicular fields of view pointed at the Earth's limb, observing the Doppler shift of the atomic oxygen red and green lines at 630.0 nm and 557.7 nm wavelength. The wavelength shift is measured using field-widened, temperature compensated Doppler Asymmetric Spatial Heterodyne (DASH) spectrometers, employing low order échelle gratings operating at two different orders for the different atmospheric lines. The temperature measurement is accomplished by a multichannel photometric measurement of the spectral shape of the molecular oxygen A-band around 762 nm wavelength. For each field of view, the signals of the two oxygen lines and the A-band are detected on different regions of a single, cooled, frame transfer charge coupled device (CCD) detector. On-board calibration sources are used to periodically quantify thermal drifts, simultaneously with observing the atmosphere. The MIGHTI requirements, the resulting instrument design and the calibration are described.

  10. Computerized lateral-shear interferometer

    Science.gov (United States)

    Hasegan, Sorin A.; Jianu, Angela; Vlad, Valentin I.

    1998-07-01

    A lateral-shear interferometer, coupled with a computer for laser wavefront analysis, is described. A CCD camera is used to transfer the fringe images through a frame-grabber into a PC. 3D phase maps are obtained by fringe pattern processing using a new algorithm for direct spatial reconstruction of the optical phase. The program describes phase maps by Zernike polynomials yielding an analytical description of the wavefront aberration. A compact lateral-shear interferometer has been built using a laser diode as light source, a CCD camera and a rechargeable battery supply, which allows measurements in-situ, if necessary.

  11. Interferometric filters for spectral discrimination in high-spectral-resolution lidar: performance comparisons between Fabry-Perot interferometer and field-widened Michelson interferometer.

    Science.gov (United States)

    Cheng, Zhongtao; Liu, Dong; Yang, Yongying; Yang, Liming; Huang, Hanlu

    2013-11-10

    Thanks to wavelength flexibility, interferometric filters such as Fabry-Perot interferometers (FPIs) and field-widened Michelson interferometers (FWMIs) have shown great convenience for spectrally separating the molecule and aerosol scattering components in the high-spectral-resolution lidar (HSRL) return signal. In this paper, performance comparisons between the FPI and FWMI as a spectroscopic discrimination filter in HSRL are performed. We first present a theoretical method for spectral transmission analysis and quantitative evaluation on the spectral discrimination. Then the process in determining the parameters of the FPI and FWMI for the performance comparisons is described. The influences from the incident field of view (FOV), the cumulative wavefront error induced by practical imperfections, and the frequency locking error on the spectral discrimination performance of the two filters are discussed in detail. Quantitative analyses demonstrate that FPI can produce higher transmittance while the remarkable spectral discrimination is one of the most appealing advantages of FWMI. As a result of the field-widened design, the FWMI still performs well even under the illumination with large FOV while the FPI is only qualified for a small incident angle. The cumulative wavefront error attaches a great effect on the spectral discrimination performance of the interferometric filters. We suggest if a cumulative wavefront error is less than 0.05 waves RMS, it is beneficial to employ the FWMI; otherwise, FPI may be more proper. Although the FWMI shows much more sensitivity to the frequency locking error, it can outperform the FPI given a locking error less than 0.1 GHz is achieved. In summary, the FWMI is very competent in HSRL applications if these practical engineering and control problems can be solved, theoretically. Some other estimations neglected in this paper can also be carried out through the analytical method illustrated herein.

  12. Direct-reading type microwave interferometer

    International Nuclear Information System (INIS)

    Matsuura, Kiyokata; Fujita, Junji; Ogata, Atsushi; Haba, Kiichiro.

    1977-10-01

    A new microwave interferometer has been developed and applied to the electron density measurement on JIPP T-II plasma device. The interferometer generates an output voltage proportional to the number of fringe shifts and also output pulses which indicate the change of electron density for the convenience of data processing, where the resolution is a quarter of fringe shift. The principle is based on the digitization of fringe shifts utilizing the phase detection of microwave signals with two-level modulation of source frequency. With this system and 70 GHz microwave source, a change of electron density as rapid as about 2 x 10 13 cm -3 in 1 ms has been measured at the tokamak operation of JIPP T-II. (auth.)

  13. Atom Wave Interferometers

    National Research Council Canada - National Science Library

    Pritchard, David

    1999-01-01

    Matter wave interferometers, in which de Broglie waves are coherently split and then recombined to produce interference fringes, have opened exciting new possibilities for precision and fundamental...

  14. Quasi-quadrature interferometer for plasma density radial profile measurements

    International Nuclear Information System (INIS)

    Lowenthal, D.D.; Hoffman, A.L.

    1979-01-01

    A cw Mach Zehnder multichannel interferometer has been developed to measure time-dependent fractional fringe shifts with an accuracy of one-fortieth fringe. The design is quasi-quadrature in that known phase shifts, introduced in the reference beam, are time multiplexed with the normal reference beam. This technique requires only one detector per interferometer channel as compared to two detectors for most quadrature designs. The quadrature information makes the sense of density changes unambiguous, it automatically calibrates the instrument during the plasma event, and it makes fringe shift measurements virtually independent of fringe contrast fluctuations caused by plasma refractive and/or absorptive effects. The interferometer optical design is novel in that the electro-optic crystal used to introduce the 90 0 phase shifts is located in the common 2-mm-diam HeNe entrance beam to the interferometer, by exploiting polarization techniques, rather than in the expanded 1--2-cm reference beam itself. This arrangement greatly reduces the size, cost, and high-voltage requirements for the phase modulating crystal

  15. Absolute distance measurement with micrometer accuracy using a Michelson interferometer and the iterative synthetic wavelength principle.

    Science.gov (United States)

    Alzahrani, Khaled; Burton, David; Lilley, Francis; Gdeisat, Munther; Bezombes, Frederic; Qudeisat, Mohammad

    2012-02-27

    We present a novel system that can measure absolute distances of up to 300 mm with an uncertainty of the order of one micrometer, within a timeframe of 40 seconds. The proposed system uses a Michelson interferometer, a tunable laser, a wavelength meter and a computer for analysis. The principle of synthetic wave creation is used in a novel way in that the system employs an initial low precision estimate of the distance, obtained using a triangulation, or time-of-flight, laser system, or similar, and then iterates through a sequence of progressively smaller synthetic wavelengths until it reaches micrometer uncertainties in the determination of the distance. A further novel feature of the system is its use of Fourier transform phase analysis techniques to achieve sub-wavelength accuracy. This method has the major advantages of being relatively simple to realize, offering demonstrated high relative precisions better than 5 × 10(-5). Finally, the fact that this device does not require a continuous line-of-sight to the target as is the case with other configurations offers significant advantages.

  16. Field-widened Michelson interferometer for spectral discrimination in high-spectral-resolution lidar: practical development.

    Science.gov (United States)

    Cheng, Zhongtao; Liu, Dong; Zhang, Yupeng; Yang, Yongying; Zhou, Yudi; Luo, Jing; Bai, Jian; Shen, Yibing; Wang, Kaiwei; Liu, Chong; Su, Lin; Yang, Liming

    2016-04-04

    A field-widened Michelson interferometer (FWMI), which is intended as the spectroscopic discriminator in ground-based high-spectral-resolution lidar (HSRL) for atmospheric aerosol detection, is described in this paper. The structure, specifications and design of the developed prototype FWMI are introduced, and an experimental approach is proposed to optimize the FWMI assembly and evaluate its comprehensive characteristic simultaneously. Experimental results show that, after optimization process, the peak-to-valley (PV) value and root-mean-square (RMS) value of measured OPD variation for the FWMI are 0.04λ and 0.008λ respectively among the half divergent angle range of 1.5 degree. Through an active locking technique, the frequency of the FWMI can be locked to the laser transmitter with accuracy of 27 MHz for more than one hour. The practical spectral discrimination ratio (SDR) for the developed FWMI is evaluated to be larger than 86 if the divergent angle of incident beam is smaller than 0.5 degree. All these results demonstrate the great potential of the developed FWMI as the spectroscopic discriminator for HSRLs, as well as the feasibility of the proposed design and optimization process. This paper is expected to provide a good entrance for the lidar community in future HSRL developments using the FWMI technique.

  17. Optimized Beam Sculpting with Generalized Fringe-rate Filters

    Science.gov (United States)

    Parsons, Aaron R.; Liu, Adrian; Ali, Zaki S.; Cheng, Carina

    2016-03-01

    We generalize the technique of fringe-rate filtering, whereby visibilities measured by a radio interferometer are re-weighted according to their temporal variation. As the Earth rotates, radio sources traverse through an interferometer’s fringe pattern at rates that depend on their position on the sky. Capitalizing on this geometric interpretation of fringe rates, we employ time-domain convolution kernels to enact fringe-rate filters that sculpt the effective primary beam of antennas in an interferometer. As we show, beam sculpting through fringe-rate filtering can be used to optimize measurements for a variety of applications, including mapmaking, minimizing polarization leakage, suppressing instrumental systematics, and enhancing the sensitivity of power-spectrum measurements. We show that fringe-rate filtering arises naturally in minimum variance treatments of many of these problems, enabling optimal visibility-based approaches to analyses of interferometric data that avoid systematics potentially introduced by traditional approaches such as imaging. Our techniques have recently been demonstrated in Ali et al., where new upper limits were placed on the 21 {cm} power spectrum from reionization, showcasing the ability of fringe-rate filtering to successfully boost sensitivity and reduce the impact of systematics in deep observations.

  18. Atom Wave Interferometers

    National Research Council Canada - National Science Library

    Pritchard, David

    2000-01-01

    Long-term research objective: Matter wave interferometers, in which de Broglie waves are coherently split and then recombined to produce interference fringes, have opened exciting new possibilities for precision and fundamental...

  19. GMTR: two-dimensional geo-fit multitarget retrieval model for michelson interferometer for passive atmospheric sounding/environmental satellite observations.

    Science.gov (United States)

    Carlotti, Massimo; Brizzi, Gabriele; Papandrea, Enzo; Prevedelli, Marco; Ridolfi, Marco; Dinelli, Bianca Maria; Magnani, Luca

    2006-02-01

    We present a new retrieval model designed to analyze the observations of the Michelson Interferometer for Passive Atmospheric Sounding (MIPAS), which is on board the ENVironmental SATellite (ENVISAT). The new geo-fit multitarget retrieval model (GMTR) implements the geo-fit two-dimensional inversion for the simultaneous retrieval of several targets including a set of atmospheric constituents that are not considered by the ground processor of the MIPAS experiment. We describe the innovative solutions adopted in the inversion algorithm and the main functionalities of the corresponding computer code. The performance of GMTR is compared with that of the MIPAS ground processor in terms of accuracy of the retrieval products. Furthermore, we show the capability of GMTR to resolve the horizontal structures of the atmosphere. The new retrieval model is implemented in an optimized computer code that is distributed by the European Space Agency as "open source" in a package that includes a full set of auxiliary data for the retrieval of 28 atmospheric targets.

  20. Michelson interferometer design for Linac Coherent Light Source (LCLS) applications in the 15-1.5 Aa wavelength range

    International Nuclear Information System (INIS)

    Tatchyn, Roman

    2000-01-01

    In recent years the continuing development of linac-driven X-Ray Free Electron Laser (XRFEL) designs has significantly expanded the parameter space associated with 3rd and earlier-generation synchrotron radiation sources. In particular, in contrast to the >100 ps pulse durations typical of storage rings, temporal lengths extending down to the <100 fs regime will become available. For example, for the SLAC Linac Coherent Light Source (LCLS) a pulse duration of ∼200-300 fs with finer temporal features extending down to ∼1 fs is anticipated. The characterization of the phase space distributions of such pulses poses a significant challenge for instrumentation design both with regard to the brevity of the pulse structure as well as the X-ray (15-1.5 Aa) wavelength range of the FEL line. In this paper we assess a Michelson interferometer design aimed at characterizing the coherence length of the SLAC LCLS and discuss considerations related to its operation

  1. Development of holographic interferometer for non-destructive testing

    International Nuclear Information System (INIS)

    Kim, Cheol Jung; Baik, Sung Hoon; Shin, Jang Soo; Cho, Jai Wan; Kim, Duk Hyeon; Hong, Suck Kyoung; Lee, Sang Kil; Kim, Heon Jun; Park, Chang Jin

    1993-02-01

    This project sets the goal at development of holographic interferometer. In this interferometer, fringe localization and imaging of object are considered. And collimated beam and wedge are used for the high-speed recording and formation of carrier fringes, respectively. With this real-time holographic interferometer, not only experiments were conducted on natural convection and flame jet, but also on high speed flow phenomena such as shock wave propagation. Visualization of high-speed flow is recorded in high-speed camera with framing rate ∼ 35000f/s. And to analyze axis symmetric phase object, analysis program was developed. (Author)

  2. O2 atmospheric band measurements with WINDII: Performance of a narrow band filter/wide angle Michelson combination in space

    International Nuclear Information System (INIS)

    Ward, W.E.; Hersom, C.H.; Tai, C.C.; Gault, W.A.; Shepherd, G.G.; Solheim, B.H.

    1994-01-01

    Among the emissions viewed by the Wind Imaging Interferometer (WINDII) on the Upper Atmosphere Research Satellite (UARS) are selected lines in the (0-0) transition of the O2 atmospheric band. These lines are viewed simultaneously using a narrow band filter/wide-angle Michelson interferometer combination. The narrow band filter is used to separate the lines on the CCD (spectral-spatial scanning) and the Michelson used to modulate the emissions so that winds and rotational temperatures may be measured from the Doppler shifts and relative intensities of the lines. In this report this technique will be outlined and the on-orbit behavior since launch summarized

  3. A wave optics approach to the theory of the Michelson-Morley experiment

    Science.gov (United States)

    Smid, Thomas

    2017-11-01

    A consistent classical wave optics approach to the theory of the Michelson-Morley experiment shows that the original theory as applied by Michelson and Morley and others does not calculate the optical paths of the two beams correctly, primarily because of incorrectly assuming a right angle reflection in the instrument’s reference frame for the transverse beam, but also because of the incorrect assumption of aberration for the wave fronts. The theory presented in this work proves the expected variation of the phase difference when rotating the interferometer to be more than twice as large and also strongly asymmetrical around the zero line.

  4. Feedback-stabilized dual-beam laser interferometer for plasma measurements

    International Nuclear Information System (INIS)

    Yasuda, A.; Kanai, Y.; Kusunoki, J.; Kawahata, K.; Takeda, S.

    1980-01-01

    A stabilized laser interferometer is proposed with two beams as the light source. The fringe shift for a 0.63 μm beam of a He--Ne laser is used to stabilize the interferometer against the effect of mechanical vibrations via a feedback controlled speaker coil, while another beam of 3.39 μm, for which consequently the effect of the mechanical vibrations is excluded, is used to measure the plasma density. A stability of approx.1/500 of one fringe for 0.63 μm is obtained during a long period for frequencies lower than a few Hz. The stability for higher frequencies is limited to approx.1/30 of one fringe for 0.63 μm, which correspondes to approx.1/200 of one fringe for 3.39 μm, by the acoustic noise picked up by the speaker coil. Furthermore, the total accuracy is limited by the detector noise to approx.1/60 of one fringe for 3.39 μm, which corresponds to a line electron density of approx.5 x 10 14 cm -2 . The detector noise may be reduced by cooling the detector. The advantage of this technique over the single-laser technique is that the frequency response of the interferometer extends down to zero frequency. The interferometer is tested with the measurement of a plasma in a dynamic magnetic arcjet. Since the effect of the neutral gas background is reduced in the present interferometer, the application has an advantage for the diagnostics of plasmas produced in high pressure gases

  5. Fizeau plasma interferometer

    International Nuclear Information System (INIS)

    Frank, A.M.

    1980-01-01

    This paper describes a technique by which the sensitivity of plasma interferometers can be increased. Stabilization and fractional fringe measurement techniques have improved to the point where additional optical sensitivity could be useful

  6. Design of a speed meter interferometer proof-of-principle experiment

    International Nuclear Information System (INIS)

    Gräf, C; Barr, B W; Bell, A S; Campbell, F; Cumming, A V; Gordon, N A; Hammond, G D; Hennig, J; Houston, E A; Huttner, S H; Jones, R A; Leavey, S S; Macarthur, J; Marwick, M; Rigby, S; Sorazu, B; Spencer, A; Danilishin, S L; Lück, H; Schilling, R

    2014-01-01

    The second generation of large scale interferometric gravitational wave (GW) detectors will be limited by quantum noise over a wide frequency range in their detection band. Further sensitivity improvements for future upgrades or new detectors beyond the second generation motivate the development of measurement schemes to mitigate the impact of quantum noise in these instruments. Two strands of development are being pursued to reach this goal, focusing both on modifications of the well-established Michelson detector configuration and development of different detector topologies. In this paper, we present the design of the world's first Sagnac speed meter (SSM) interferometer, which is currently being constructed at the University of Glasgow. With this proof-of-principle experiment we aim to demonstrate the theoretically predicted lower quantum noise in a Sagnac interferometer compared to an equivalent Michelson interferometer, to qualify SSM for further research towards an implementation in a future generation large scale GW detector, such as the planned Einstein telescope observatory. (paper)

  7. Ghost fringe removal techniques using Lissajous data presentation.

    Science.gov (United States)

    Erskine, David J; Eggert, J H; Celliers, P M; Hicks, D G

    2016-03-01

    A VISAR (Velocity Interferometer System for Any Reflector) is a Doppler velocity interferometer which is an important optical diagnostic in shockwave experiments at the national laboratories, used to measure equation of state (EOS) of materials under extreme conditions. Unwanted reflection of laser light from target windows can produce an additional component to the VISAR fringe record that can distort and obscure the true velocity signal. Accurately removing this so-called ghost artifact component is essential for achieving high accuracy EOS measurements, especially when the true light signal is only weakly reflected from the shock front. Independent of the choice of algorithm for processing the raw data into a complex fringe signal, we have found it beneficial to plot this signal as a Lissajous and seek the proper center of this path, even under time varying intensity which can shift the perceived center. The ghost contribution is then solved by a simple translation in the complex plane that recenters the Lissajous path. For continuous velocity histories, we find that plotting the fringe magnitude vs nonfringing intensity and optimizing linearity is an invaluable tool for determining accurate ghost offsets. For discontinuous velocity histories, we have developed graphically inspired methods which relate the results of two VISARs having different velocity per fringe proportionalities or assumptions of constant fringe magnitude to find the ghost offset. The technique can also remove window reflection artifacts in generic interferometers, such as in the metrology of surfaces.

  8. Quadratic Sagnac effect — the influence of the gravitational potential of the Coriolis force on the phase difference between the arms of a rotating Michelson interferometer (an explanation of D C Miller's experimental results, 1921 – 1926)

    International Nuclear Information System (INIS)

    Malykin, G B; Pozdnyakova, V I

    2015-01-01

    It is shown that when an equal-arm Michelson interferometer is involved in rotation (for example, Earth's rotation around its axis or around the Sun) and its arms are oriented differently with respect to the plane of rotation, a phase difference arises between the light rays that pass through different arms. This phase difference is due to the fact that the arms experience variously the Newtonian (nonrelativistic) scalar gravitational potential of the Coriolis forces. It is shown that the phase difference is proportional to the length of the interferometer arm, the square of the angular velocity of the rotation, and the square of the distance from the center of rotation — hence, the proposal to call this phenomenon the quadratic Sagnac effect. In the present paper, we consider, as an illustrative example, the results of the once well-known experiments of D C Miller, who claimed to observe the translational motion of Earth relative to the hypothetical ‘luminiferous ether’. It is shown that this claim can actually be explained by the fact that, because of the orbital revolution of Earth, the time dilations in the orthogonal arms of the Michelson interferometer are influenced differently by the scalar gravitational potential of the Coriolis forces. (methodological notes)

  9. Influence of the tilting reflection mirror on the temperature and wind velocity retrieved by a polarizing atmospheric Michelson interferometer.

    Science.gov (United States)

    Zhang, Chunmin; Li, Ying

    2012-09-20

    The principles of a polarizing atmospheric Michelson interferometer are outlined. The tilt of its reflection mirror results in deflection of the reflected beam and affects the intensities of the observed inteferogram. This effect is systematically analyzed. Both rectangular and circular apertures are considered. The theoretical expression of the modulation depth and phase of the interferogram are derived. These parameters vary with the inclination angle of the mirror and the distance between the deflection center and the optical axis and significantly influence the retrieved temperature and wind speed. If the wind and temperature errors are required to be less than 3 m/s and 5 K, the deflection angle must be less than 0.5°. The errors are also dependent on the shape of aperture. If the reflection mirror is deflected in one direction, the temperature error is smaller for a circular aperture (1.3 K) than for a rectangular one (2.6 K), but the wind velocity errors are almost the same (less than 3 m/s). If the deflection center and incident light beam are coincident, the temperature errors are 3 × 10(-4) K and 0.45 K for circular and rectangular apertures, respectively. The wind velocity errors are 1.2 × 10(-3) m/s and 0.06 m/s. Both are small. The result would be helpful for theoretical research and development of the static polarization wind imaging interferometer.

  10. Correlation functions formed by a femtosecond pulse interferometer

    NARCIS (Netherlands)

    Cui, M.; Bhattacharya, N.; Urbach, H.P.; Van den berg, S.A.

    2008-01-01

    We experimentally demonstrate that a stabilized femtosecond frequency comb can be applied as a tool for distance measurement. The scheme is based on optical interference between individual pulses in a Michelson type interferometer. The cross-correlation functions between individual pulses with a

  11. Fringe counting method for synthetic phase with frequency-modulated laser diodes

    International Nuclear Information System (INIS)

    Onodera, Ribun; Sakuyama, Munechika; Ishii, Yukihiro

    2007-01-01

    Fringe counting method with laser diodes (LDs) for displacement measurement has been constructed. Two LDs are frequency modulated by mutually inverted sawtooth currents on an unbalanced two-beam interferometer. The mutually inverted sawtooth-current modulation of LDs produces interference fringe signals with opposite signs for respective wavelengths. The two fringe signals are fed to an electronic mixer to produce a synthetic fringe signal with a reduced sensitivity to the synthetic wavelength. Synthetic fringe pulses derived from the synthetic fringe signal make a fringe counting system possible for faster movement of the tested mirror

  12. Plasma measurement by feedback-stabilized dual-beam laser interferometer

    International Nuclear Information System (INIS)

    Yasuda, Akio; Kawahata, Kazuo; Kanai, Yasubumi.

    1982-03-01

    The plasma density in a dynamic magneto arcjet is measured by a stabilized dual-beam laser interferometer proposed by the authors. The fringe shift for a 0.63 μm beam of He-Ne laser is used to stabilize the interferometer against the effect of mechanical vibration by means of a feedback controlled speaker coil, while the other beam of 3.39 μm, for which the effect of mechanical vibrations is excluded, is used to measure plasma density. Stability of --1/500 of one fringe for 0.63 μm is obtained during a long period for frequencies lower than a few Hertz. Stability for higher frequencies, which determines the accuracy of the present measurement, is limited to --1/30 of one fringe for 0.63 μm, which corresponds to --1/200 of one fringe and a line electron density of --1.5 x 10 14 cm - 2 for 3.39 μm, by acoustic noise picked up by the speaker coil. The advantage of this technique over the single-laser technique is that the frequency response of the interferometer extends down to zero frequency. Since the effect of the neutral gas background is practically reduced to zero, the present interferometer is to be applied advantageously to the diagnostics of the plasma produced in high pressure gases. (author)

  13. Virgo: a laser interferometer to detect gravitational waves

    NARCIS (Netherlands)

    Accadia, T.; van den Brand, J.F.J.; Bulten, H.J.; Ketel, T.J.; van der Voet, H.; Mul, F.A.; Rabeling, D.S.

    2012-01-01

    This paper presents a complete description of Virgo, the French-Italian gravitational wave detector. The detector, built at Cascina, near Pisa (Italy), is a very large Michelson interferometer, with 3 km-long arms. In this paper, following a presentation of the physics requirements, leading to the

  14. Potentiality of an orbiting interferometer for space-time experiments

    International Nuclear Information System (INIS)

    Grassi Strini, A.M.; Strini, G.; Tagliaferri, G.

    1979-01-01

    It is suggested that by putting a Michelson interferometer aboard a spacecraft orbiting around the earth, very substantial progress could be made in space-time experiments. It is estimated that in measurements of e.g. some anisotropy of the light velocity, a spacecraft-borne interferometer of quite small size (0.1 m arm-length) would reach a sensitivity greater by a factor of approximately 10 8 than the best achievements to date of ground-based devices. (author)

  15. The use of x-ray interferometry to investigate the linearity of the NPL Differential Plane Mirror Optical Interferometer

    Science.gov (United States)

    Yacoot, Andrew; Downs, Michael J.

    2000-08-01

    The x-ray interferometer from the combined optical and x-ray interferometer (COXI) facility at NPL has been used to investigate the performance of the NPL Jamin Differential Plane Mirror Interferometer when it is fitted with stabilized and unstabilized lasers. This Jamin interferometer employs a common path design using a double pass configuration and one fringe is realized by a displacement of 158 nm between its two plane mirror retroreflectors. Displacements over ranges of several optical fringes were measured simultaneously using the COXI x-ray interferometer and the Jamin interferometer and the results were compared. In order to realize the highest measurement accuracy from the Jamin interferometer, the air paths were shielded to prevent effects from air turbulence and electrical signals generated by the photodetectors were analysed and corrected using an optimizing routine in order to subdivide the optical fringes accurately. When an unstabilized laser was used the maximum peak-to-peak difference between the two interferometers was 80 pm, compared with 20 pm when the stabilized laser was used.

  16. Two-photon interference of polarization-entangled photons in a Franson interferometer.

    Science.gov (United States)

    Kim, Heonoh; Lee, Sang Min; Kwon, Osung; Moon, Han Seb

    2017-07-18

    We present two-photon interference experiments with polarization-entangled photon pairs in a polarization-based Franson-type interferometer. Although the two photons do not meet at a common beamsplitter, a phase-insensitive Hong-Ou-Mandel type two-photon interference peak and dip fringes are observed, resulting from the two-photon interference effect between two indistinguishable two-photon probability amplitudes leading to a coincidence detection. A spatial quantum beating fringe is also measured for nondegenerate photon pairs in the same interferometer, although the two-photon states have no frequency entanglement. When unentangled polarization-correlated photons are used as an input state, the polarization entanglement is successfully recovered through the interferometer via delayed compensation.

  17. CO laser interferometer for REB-plasma experiments

    International Nuclear Information System (INIS)

    Burmasov, V.S.; Kruglyakov, E.P.

    1996-01-01

    The Michelson carbon oxide laser interferometer for measuring plasma density in studies on REB-plasma interaction is described. A detail description of the interferometer and CO laser is presented. For a selection of a single wavelength laser operation the CaF 2 prism is applied. A Ge:Au photoconductor at 77 deg K is applied as the detector. The CO laser radiation at λ 5.34 μm coincides with the detector maximum sensitivity (of the order of 1000 V/W). This increases the interferometer sensitivity about ten times with respect to the He-Ne laser (λ = 3.39 μm) used as the source of light. The typical interferogram and time evolution of plasma density obtained at GOL-M device are presented. (author). 3 figs., 5 refs

  18. CO laser interferometer for REB-plasma experiments

    Energy Technology Data Exchange (ETDEWEB)

    Burmasov, V S; Kruglyakov, E P [Budker Inst. of Nuclear Physics, Novosibirsk (Russian Federation)

    1997-12-31

    The Michelson carbon oxide laser interferometer for measuring plasma density in studies on REB-plasma interaction is described. A detail description of the interferometer and CO laser is presented. For a selection of a single wavelength laser operation the CaF{sub 2} prism is applied. A Ge:Au photoconductor at 77 deg K is applied as the detector. The CO laser radiation at {lambda} 5.34 {mu}m coincides with the detector maximum sensitivity (of the order of 1000 V/W). This increases the interferometer sensitivity about ten times with respect to the He-Ne laser ({lambda} = 3.39 {mu}m) used as the source of light. The typical interferogram and time evolution of plasma density obtained at GOL-M device are presented. (author). 3 figs., 5 refs.

  19. Reducing the first-order Doppler shift in a Sagnac interferometer

    NARCIS (Netherlands)

    Hannemann, S.; Salumbides, E.J.; Ubachs, W.M.G.

    2007-01-01

    We demonstrate a technique to reduce first-order Doppler shifts in crossed atomic/molecular and laser beam setups by aligning two counterpropagating laser beams as part of a Sagnac interferometer. Interference fringes on the exit port of the interferometer reveal minute deviations from perfect

  20. Alignment procedure for the VIRGO interferometer: experimental results from the Frascati Prototype

    International Nuclear Information System (INIS)

    Babusci, D.; Giordano, G.; Matone, G.; Matone, L.; Sannibale, V.

    1996-07-01

    A small fixed-mirrors Michelson interferometer has been suggested for VIRGO. The experimental results are excellent and fully confirm the adequacy of the method. The minimum angular misalignment that can be detected in the present set-up is 10 nrad

  1. Modeling of the fringe shift in multiple beam interference for glass ...

    Indian Academy of Sciences (India)

    A quadratic model is suggested to describe the fringe shift occurred due to the phase variations of uncladded glass fiber introduced between the two plates of the liquid wedge interferometer. The fringe shift of the phase object is represented in the harmonic term which appears in the denominator of the Airy distribution ...

  2. Accurately computing the optical pathlength difference for a michelson interferometer with minimal knowledge of the source spectrum.

    Science.gov (United States)

    Milman, Mark H

    2005-12-01

    Astrometric measurements using stellar interferometry rely on precise measurement of the central white light fringe to accurately obtain the optical pathlength difference of incoming starlight to the two arms of the interferometer. One standard approach to stellar interferometry uses a channeled spectrum to determine phases at a number of different wavelengths that are then converted to the pathlength delay. When throughput is low these channels are broadened to improve the signal-to-noise ratio. Ultimately the ability to use monochromatic models and algorithms in each of the channels to extract phase becomes problematic and knowledge of the spectrum must be incorporated to achieve the accuracies required of the astrometric measurements. To accomplish this an optimization problem is posed to estimate simultaneously the pathlength delay and spectrum of the source. Moreover, the nature of the parameterization of the spectrum that is introduced circumvents the need to solve directly for these parameters so that the optimization problem reduces to a scalar problem in just the pathlength delay variable. A number of examples are given to show the robustness of the approach.

  3. Supplement to the paper 'Quadratic Sagnac effect — the influence of the gravitational potential of the Coriolis force on the phase difference between the arms of a rotating Michelson interferometer (an explanation of D C Miller's experimental results, 1921 – 1926)' (Usp. Fiz. Nauk185 431 (2015) [Phys. Usp.58 398 (2015)])

    International Nuclear Information System (INIS)

    Malykin, G B; Pozdnyakova, V I

    2015-01-01

    The paper 'Quadratic Sagnac effect — the influence of the gravitational potential of the Coriolis force on the phase difference between the arms of a rotating Michelson interferometer (an explanation of D C Miller's experimental results, 1921 – 1926)' (Usp. Fiz. Nauk 185 431 (2015) [Phys. Usp. 58 398 (2015)]) is amended and supplemented with information concerning earlier work on the influence of rotation on Michelson – Morley's nonzero results. (letters to the editors)

  4. Fine art of computing nulling interferometer maps

    Science.gov (United States)

    Hénault, F.

    2008-07-01

    Spaceborne nulling interferometers are often characterized by means of their nulling ratio, which is defined as the deepest possible extinction of one target star supposed to harbor an extra-solar system. Herein is shown that another parameter, which is the transmitting efficiency of nearby bright fringes, is also of prime importance. More generally, "nulling maps" formed by the whole destructive and constructive fringe pattern projected on-sky, are found to be very sensitive on the design of some subsystems constituting the interferometer. In particular, we consider Spatial Filtering (SF) and Achromatic Phase Shifter (APS) devices, both required achieving planet detection and characterization. Consequences of the SF choice (pinhole or single-mode optical fiber) and APS properties (with or without induced pupil-flip) are discussed, for both monochromatic and polychromatic cases. Examples of numerical simulations are provided for single Bracewell interferometer, Angel cross and X-array configurations, demonstrating noticeable differences in the aspect of resulting nulling maps. It is concluded that both FS and APS designs exhibit variable capacities for serendipitous planet discovery.

  5. White light spectral interferometer for measuring dispersion in the visible-near infrared

    Science.gov (United States)

    Arosa, Yago; Rodríguez Fernández, Carlos Damian; Algnamat, Bilal S.; López-Lago, Elena; de la Fuente, Raul

    2017-08-01

    We have designed a spectrally resolved interferometer to measure the refractive index of transparent samples over a wide spectral band from 400 to 1550 nm. The measuring device consists of a Michelson interferometer whose output is analyzed by means of three fiber spectrometers. The first one is a homemade prism spectrometer, which obtains the interferogram produced by the sample over 400 to 1050 nm; the second one is a homemade transmission grating spectrometer thought to measure the interferogram in the near infrared spectral band from 950 to 1550 nm; the last one is a commercial Czerny-Turner spectrometer used to make high precision measurements of the displacement between the Michelson mirrors also using white light interferometry. The whole system is illuminated by a white light source with an emission spectrum similar to black body. We have tested the instrument with solid and liquids samples achieving accuracy to the fourth decimal on the refractive index after fitting it to a Cauchy formula

  6. Interferometers as probes of Planckian quantum geometry

    Science.gov (United States)

    Hogan, Craig J.

    2012-03-01

    A theory of position of massive bodies is proposed that results in an observable quantum behavior of geometry at the Planck scale, tP. Departures from classical world lines in flat spacetime are described by Planckian noncommuting operators for position in different directions, as defined by interactions with null waves. The resulting evolution of position wave functions in two dimensions displays a new kind of directionally coherent quantum noise of transverse position. The amplitude of the effect in physical units is predicted with no parameters, by equating the number of degrees of freedom of position wave functions on a 2D space-like surface with the entropy density of a black hole event horizon of the same area. In a region of size L, the effect resembles spatially and directionally coherent random transverse shear deformations on time scale ≈L/c with typical amplitude ≈ctPL. This quantum-geometrical “holographic noise” in position is not describable as fluctuations of a quantized metric, or as any kind of fluctuation, dispersion or propagation effect in quantum fields. In a Michelson interferometer the effect appears as noise that resembles a random Planckian walk of the beam splitter for durations up to the light-crossing time. Signal spectra and correlation functions in interferometers are derived, and predicted to be comparable with the sensitivities of current and planned experiments. It is proposed that nearly colocated Michelson interferometers of laboratory scale, cross-correlated at high frequency, can test the Planckian noise prediction with current technology.

  7. An interferometric velocity calibrator for 73Ge Moessbauer spectrometer

    International Nuclear Information System (INIS)

    Chow, L.; Kimble, T.

    1987-01-01

    A velocity calibrator based on a laser driven Michelson interferometer was designed for a 73 Ge Moessbauer spectrometer in the range of 100 to 500 μm/sec. The conventional method of counting the interference fringes cannot be used in this case because the displacement only spans about 3 to 15 μm and only a few fringes can be observed during one velocity sweep. The velocity calibration obtained this way was compared with the calibration obtained from 57 Fe measurement, and excellent agreement was found between the two methods. (orig.)

  8. Note: Using a Kösters prism to create a fringe pattern.

    Science.gov (United States)

    Capellmann, R F; Bewerunge, J; Platten, F; Egelhaaf, S U

    2017-05-01

    The interference of two crossed laser beams results in a standing wave. Such fringe patterns are exploited in different instruments such as interferometers or laser-Doppler anemometers. We create a fringe pattern in the sample plane of a microscope using a compact apparatus based on a Kösters prism. The fringe pattern is shown to be spatially and temporally very stable, covers a large area, and its spacing is easily tunable. In addition, we exploit it to impose a sinusoidal potential on colloidal particles.

  9. All-silicon Michelson instrument on chip: Distance and surface profile measurement and prospects for visible light spectrometry

    International Nuclear Information System (INIS)

    Malak, M.; Marty, F.; Bourouina, T.; Nouira, H.; Vailleau, G.

    2013-01-01

    A miniature Michelson interferometer is analyzed theoretically and experimentally. The fabricated micro-interferometer is incorporated at the tip of a monolithic silicon probe to achieve contactless distance measurements and surface profilometry. For infrared operation, two approaches are studied, based on the use of monochromatic light and wavelength sweep, respectively. A theoretical model is devised to depict the system characteristics taking into account Gaussian beam divergence and light spot size. Furthermore, preliminary results using visible light demonstrate operation of the probe as a visible light spectrometer, despite silicon absorbance, thanks to the micrometer thickness involved in the beam splitter.

  10. All-silicon Michelson instrument on chip: Distance and surface profile measurement and prospects for visible light spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Malak, M.; Marty, F.; Bourouina, T. [Universite Paris-Est, Laboratoire ESYCOM, ESIEE Paris, Cite Descartes, 2 Boulevard Blaise Pascal, 93162 Noisy-le-Grand Cedex (France); Nouira, H.; Vailleau, G. [Laboratoire National de Metrologie et d' Essais, 1 rue Gaston Boissier, 75724 Paris Cedex 15 (France)

    2013-04-08

    A miniature Michelson interferometer is analyzed theoretically and experimentally. The fabricated micro-interferometer is incorporated at the tip of a monolithic silicon probe to achieve contactless distance measurements and surface profilometry. For infrared operation, two approaches are studied, based on the use of monochromatic light and wavelength sweep, respectively. A theoretical model is devised to depict the system characteristics taking into account Gaussian beam divergence and light spot size. Furthermore, preliminary results using visible light demonstrate operation of the probe as a visible light spectrometer, despite silicon absorbance, thanks to the micrometer thickness involved in the beam splitter.

  11. High-accuracy self-mixing interferometer based on single high-order orthogonally polarized feedback effects.

    Science.gov (United States)

    Zeng, Zhaoli; Qu, Xueming; Tan, Yidong; Tan, Runtao; Zhang, Shulian

    2015-06-29

    A simple and high-accuracy self-mixing interferometer based on single high-order orthogonally polarized feedback effects is presented. The single high-order feedback effect is realized when dual-frequency laser reflects numerous times in a Fabry-Perot cavity and then goes back to the laser resonator along the same route. In this case, two orthogonally polarized feedback fringes with nanoscale resolution are obtained. This self-mixing interferometer has the advantages of higher sensitivity to weak signal than that of conventional interferometer. In addition, two orthogonally polarized fringes are useful for discriminating the moving direction of measured object. The experiment of measuring 2.5nm step is conducted, which shows a great potential in nanometrology.

  12. Improvement of input power dynamic range for 20 Gbit/s optical WDM switch nodes using an integrated Michelson wavelength converter

    DEFF Research Database (Denmark)

    Danielsen, Søren Lykke; Hansen, Peter Bukhave; Jørgensen, Carsten

    1997-01-01

    be improved compared to switch blocks without IWCs. This is especially important at high bit rates where the cascadability of the SOA gates decreases. Here, more than 15 dB improvement of the input power dynamic range is achieved at 20 Gbit/s using a high-speed Michelson interferometer wavelength converter...

  13. Spectral dispersion and fringe detection in IOTA

    Science.gov (United States)

    Traub, W. A.; Lacasse, M. G.; Carleton, N. P.

    1990-01-01

    Pupil plane beam combination, spectral dispersion, detection, and fringe tracking are discussed for the IOTA interferometer. A new spectrometer design is presented in which the angular dispersion with respect to wavenumber is nearly constant. The dispersing element is a type of grism, a series combination of grating and prism, in which the constant parts of the dispersion add, but the slopes cancel. This grism is optimized for the display of channelled spectra. The dispersed fringes can be tracked by a matched-filter photon-counting correlator algorithm. This algorithm requires very few arithmetic operations per detected photon, making it well-suited for real-time fringe tracking. The algorithm is able to adapt to different stellar spectral types, intensity levels, and atmospheric time constants. The results of numerical experiments are reported.

  14. The POLIS interferometer for ponderomotive squeezed light generation

    Energy Technology Data Exchange (ETDEWEB)

    Calloni, Enrico [Dipartimento di Fisica, Università degli Studi di Napoli “Federico II”, Napoli (Italy); INFN, Sezione di Napoli (Italy); Conte, Andrea [Dipartimento di Fisica, Università di Roma “Sapienza”, Roma (Italy); INFN, Sezione di Roma1 (Italy); De Laurentis, Martina, E-mail: martina.delaurentis@na.infn.it [Dipartimento di Fisica, Università degli Studi di Napoli “Federico II”, Napoli (Italy); INFN, Sezione di Napoli (Italy); Naticchioni, Luca [Dipartimento di Fisica, Università di Roma “Sapienza”, Roma (Italy); INFN, Sezione di Roma1 (Italy); Puppo, Paola [INFN, Sezione di Roma1 (Italy); Ricci, Fulvio [Dipartimento di Fisica, Università di Roma “Sapienza”, Roma (Italy); INFN, Sezione di Roma1 (Italy)

    2016-07-11

    POLIS (POnderomotive LIght Squeezer) is a suspended interferometer, presently under construction, devoted to the generation of ponderomotive squeezed light and to the study of the interaction of non classical quantum states of light and macroscopic objects. The interferometer is a Michelson whose half-meter long arms are constituted by high-finesse cavities, suspended to a seismic isolation chain similar to the Virgo SuperAttenuator. The mass of the suspended cavity mirrors are chosen to be tens of grams: this value is sufficiently high to permit the use of the well-tested Virgo suspension techniques but also sufficiently small to generate the coupling among the two phase quadratures with a limited amount of light in the cavity, of the order of few tens of kW. In this short paper the main features of the interferometer are shown, together with the expected sensitivity and squeezing factor.

  15. Vibration compensated high-resolution scanning white-light Linnik-interferometer

    Science.gov (United States)

    Tereschenko, Stanislav; Lehmann, Peter; Gollor, Pascal; Kuehnhold, Peter

    2017-06-01

    We present a high-resolution Linnik scanning white-light interferometer (SWLI) with integrated distance measuring interferometer (DMI) for close-to-machine applications in the presence of environmental vibrations. The distance, measured by DMI during the depth-scan, is used for vibration compensation of SWLI signals. The reconstruction of the white-light interference signals takes place after measurement by reordering the captured images in accordance with their real positions obtained by the DMI and subsequent trigonometrical approximation. This system is the further development of our previously presented Michelson-interferometer. We are able to compensate for arbitrary vibrations with frequencies up to several kilohertz and amplitudes in the lower micrometer range. Completely distorted SWLI signals can be reconstructed and the surface topography can be obtained with high accuracy. We demonstrate the feasibility of the method by examples of practical measurements with and without vibrational disturbances.

  16. Straight, conic and circular fringes in single interferogram

    International Nuclear Information System (INIS)

    Rajkumar

    2015-01-01

    Interferometry is an important part of optics courses taught at the undergraduate level in universities throughout the world. It is used to explain to students the wave nature of light and is also used to measure parameters like length, refractive index, thickness of test samples and wavelength of light source, etc. The shape of interference fringes (linear, conic or circular) gives vital information about the interfering wavefronts and is used for firsthand visual inspection in optical shop testing and other applications of scientific and engineering importance. The present work describes a simple laboratory technique to generate fringes with different shapes in a single interferogram. This is achieved by using our diffraction-Lloyd mirror interferometer where two portions of the diffracted field are superimposed to generate the interference fringes. The technique is quite helpful in explaining the role of source orientation on the shape of interference fringes to students. (paper)

  17. Development of measurement system for gauge block interferometer

    Science.gov (United States)

    Chomkokard, S.; Jinuntuya, N.; Wongkokua, W.

    2017-09-01

    We developed a measurement system for collecting and analyzing the fringe pattern images from a gauge block interferometer. The system was based on Raspberry Pi which is an open source system with python programming and opencv image manipulation library. The images were recorded by the Raspberry Pi camera with five-megapixel capacity. The noise of images was suppressed for the best result in analyses. The low noise images were processed to find the edge of fringe patterns using the contour technique for the phase shift analyses. We tested our system with the phase shift patterns between a gauge block and a reference plate. The phase shift patterns were measured by a Twyman-Green type of interferometer using the He-Ne laser with the temperature controlled at 20.0 °C. The results of the measurement will be presented and discussed.

  18. Analytic models of spectral responses of fiber-grating-based interferometers on FMC theory.

    Science.gov (United States)

    Zeng, Xiangkai; Wei, Lai; Pan, Yingjun; Liu, Shengping; Shi, Xiaohui

    2012-02-13

    In this paper the analytic models (AMs) of the spectral responses of fiber-grating-based interferometers are derived from the Fourier mode coupling (FMC) theory proposed recently. The interferometers include Fabry-Perot cavity, Mach-Zehnder and Michelson interferometers, which are constructed by uniform fiber Bragg gratings and long-period fiber gratings, and also by Gaussian-apodized ones. The calculated spectra based on the analytic models are achieved, and compared with the measured cases and those on the transfer matrix (TM) method. The calculations and comparisons have confirmed that the AM-based spectrum is in excellent agreement with the TM-based one and the measured case, of which the efficiency is improved up to ~2990 times that of the TM method for non-uniform-grating-based in-fiber interferometers.

  19. Adaptable Optical Fiber Displacement-Curvature Sensor Based on a Modal Michelson Interferometer with a Tapered Single Mode Fiber.

    Science.gov (United States)

    Salceda-Delgado, G; Martinez-Rios, A; Selvas-Aguilar, R; Álvarez-Tamayo, R I; Castillo-Guzman, A; Ibarra-Escamilla, B; Durán-Ramírez, V M; Enriquez-Gomez, L F

    2017-06-02

    A compact, highly sensitive optical fiber displacement and curvature radius sensor is presented. The device consists of an adiabatic bi-conical fused fiber taper spliced to a single-mode fiber (SMF) segment with a flat face end. The bi-conical taper structure acts as a modal coupling device between core and cladding modes for the SMF segment. When the bi-conical taper is bent by an axial displacement, the symmetrical bi-conical shape of the tapered structure is stressed, causing a change in the refractive index profile which becomes asymmetric. As a result, the taper adiabaticity is lost, and interference between modes appears. As the bending increases, a small change in the fringe visibility and a wavelength shift on the periodical reflection spectrum of the in-fiber interferometer is produced. The displacement sensitivity and the spectral periodicity of the device can be adjusted by the proper selection of the SMF length. Sensitivities from around 1.93 to 3.4 nm/mm were obtained for SMF length between 7.5 and 12.5 cm. Both sensor interrogations, wavelength shift and visibility contrast, can be used to measure displacement and curvature radius magnitudes.

  20. Imaging beyond the fringe: an update on the LINC-NIRVANA Fizeau interferometer for the LBT

    Science.gov (United States)

    Herbst, T. M.; Ragazzoni, R.; Eckart, A.; Weigelt, G.

    2010-07-01

    We present an update on the construction and integration of LINC-NIRVANA, a Fizeau-mode imaging interferometer for the Large Binocular Telescope (LBT). The LBT is a unique platform for interferometry, since its two, co-mounted 8.4 meter primary mirrors present an orientation-independent entrance pupil. This allows Fizeau-mode beam combination, providing 23-meter spatial resolution and 12-meter effective collecting area for panoramic imagery LINC-NIRVANA will sit at one of the shared, bent focal stations, receiving light from both mirrors of the LBT. The instrument uses visible wavelength radiation for wavefront control, and the near-infrared bands for science and fringe tracking. LINC-NIRVANA employs a number of innovative technologies, including multi-conjugated adaptive optics, state-of-the-art materials, low vibration mechanical coolers, active and passive control, and sophisticated software for data analysis. The instrument is in its final construction and integration phase. This paper reports on overall progress, including insights gained on large instrument assembly, software integration, science planning, and vibration control. A number of additional contributions to this conference focus on individual subsystems and integration-related issues.

  1. Sub-atomic dimensional metrology: developments in the control of x-ray interferometers

    Science.gov (United States)

    Yacoot, Andrew; Kuetgens, Ulrich

    2012-07-01

    Within the European Metrology Research Programme funded project NANOTRACE, the nonlinearity of the next generation of optical interferometers has been measured using x-ray interferometry. The x-ray interferometer can be regarded as a ruler or translation stage whose graduations or displacement steps are based on the lattice spacing of the crystallographic planes from which the x-rays are diffracted: in this case the graduations are every 192 pm corresponding to the spacing between the (2 2 0) planes in silicon. Precise displacement of the x-ray interferometer's monolithic translation stage in steps corresponding to discrete numbers of x-ray fringes requires servo positioning capability at the picometre level. To achieve this very fine control, a digital control system has been developed which has opened up the potential for advances in metrology using x-ray interferometry that include quadrature counting of x-ray fringes.

  2. Sub-atomic dimensional metrology: developments in the control of x-ray interferometers

    International Nuclear Information System (INIS)

    Yacoot, Andrew; Kuetgens, Ulrich

    2012-01-01

    Within the European Metrology Research Programme funded project NANOTRACE, the nonlinearity of the next generation of optical interferometers has been measured using x-ray interferometry. The x-ray interferometer can be regarded as a ruler or translation stage whose graduations or displacement steps are based on the lattice spacing of the crystallographic planes from which the x-rays are diffracted: in this case the graduations are every 192 pm corresponding to the spacing between the (2 2 0) planes in silicon. Precise displacement of the x-ray interferometer's monolithic translation stage in steps corresponding to discrete numbers of x-ray fringes requires servo positioning capability at the picometre level. To achieve this very fine control, a digital control system has been developed which has opened up the potential for advances in metrology using x-ray interferometry that include quadrature counting of x-ray fringes. (paper)

  3. Real-time, vibration-compensated CO2 interferometer operation on the DIII-D tokamak

    International Nuclear Information System (INIS)

    Carlstrom, T.N.; Ahlgren, D.R.; Crosbie, J.

    1988-01-01

    A multichannel, two-color, quadrature heterodyne interferometer is used to measure the line density in the DIII-D tokamak. The unique feature of this real-time vibration-compensated interferometer is the combination of high speed (1 MHz), high resolution (2π/256), and wide range ( +- 8193 fringes). Quadrature phase information from a CO 2 laser (10.6 μm) and a He--Ne laser (0.63 μm) are digitized with high-speed (6 MHz) flash digitizers. Zero crossings of the signals are counted with digital circuitry yielding quarter fringe resolution with a 4-MHz bandwidth. Further fringe resolution of 1/256 is provided at 350 kHz by a PROM which uses the digital signals as input to a look-up table. Analog line density is presently available at 80 kHz with a system noise equivalent phase shift of +- 2/256. Error monitoring is provided for low signal amplitude and exceeding the maximum fringe rate. In addition, a method to prevent coating of in-vessel mirrors due to plasma and vessel wall cleaning discharges has been developed

  4. Virgo an interferometer for gravitational wave detection

    International Nuclear Information System (INIS)

    Passaquieti, R.

    2000-01-01

    Gravitational waves propagating from rapidly accelerating star masses can be detected by means of interfer- ometric techniques. The Virgo detector is a Michelson interferometer, with two 3 km long Fabry-Perot cavities, that is going to be built in the countryside of Pisa (Italy). Principles of interferometric gravitational wave detection, and the main noise sources in the Virgo apparatus are treated. The Virgo optical scheme and its main components are also described. Finally, an overview on the status of works at the Virgo site is presented

  5. Evaluating interfacial adhesion properties of Pt/Ti thin-film by using acousto-optic technique

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hae Sung [Graduate School of Automotive Engineering, Seoul National University of Science and Technology, Seoul (Korea, Republic of); Didie, David; Yoshida, Sanichiro [Dept. of Chemistry and Physics, Southeastern Louisiana University, Hammond (United States); Park, Ik Keun [Dept. of Mechanical and Automotive Engineering, Seoul National University of Science and Technology, Seoul (Korea, Republic of)

    2016-06-15

    We propose an acousto-optic technique for the nondestructive evaluation of adhesion properties of a Pt/Ti thin-film interface. Since there are some problems encountered when using prevailing techniques to nondestructively evaluate the interfacial properties of micro/nano-scale thin-films, we applied an interferometer that combined the acoustic and optical methods. This technique is based on the Michelson interferometer but the resultant surface of the thin film specimen makes interference instead of the mirror when the interface is excited from the acoustic transducer at the driving frequency. The thin film shows resonance-like behavior at a certain frequency range, resulting in a low-contrast fringe pattern. Therefore, we represented quantitatively the change in fringe pattern as a frequency spectrum and discovered the possibility that the interfacial adhesion properties of a thin film can be evaluated using the newly proposed technique.

  6. Phase-contrast tomographic imaging using an X-ray interferometer

    Energy Technology Data Exchange (ETDEWEB)

    Momose, A. [Hitachi Ltd, Advanced Research Lab., Saitama (Japan); Takeda, T.; Itai, Y. [Univ. of Tsukuba, Inst. of Clinical Medicine, Ibaraki (Japan); Yoneyama, A. [Hitachi Ltd, Central Resarch Lab., Tokyo (Japan); Hirano, K. [High Energy Accelerator Research Organization, Inst. of Materials Structure Science, Ibaraki (Japan)

    1998-05-01

    Apparatus for phase-contrast X-ray computed tomography using a monolithic X-ray interferometer is presented with some observational results for human breast tissues. Structures characteristic of the tissues were revealed in the phase-contrast tomograms. The procedure of image analysis consists of phase retrieval from X-ray interference patterns and tomographic image reconstruction from the retrieved phase shift. Next, feasibility of phase-contrast imaging using a two-crystal X-ray interferometer was studied aiming at in vivo observation in the future. In a preliminary study, the two-crystal X-ray interferometer was capable of generating fringes of 70% visibility using synchrotron X-rays. 35 refs.

  7. Phase-contrast tomographic imaging using an X-ray interferometer

    International Nuclear Information System (INIS)

    Momose, A.; Takeda, T.; Itai, Y.; Yoneyama, A.; Hirano, K.

    1998-01-01

    Apparatus for phase-contrast X-ray computed tomography using a monolithic X-ray interferometer is presented with some observational results for human breast tissues. Structures characteristic of the tissues were revealed in the phase-contrast tomograms. The procedure of image analysis consists of phase retrieval from X-ray interference patterns and tomographic image reconstruction from the retrieved phase shift. Next, feasibility of phase-contrast imaging using a two-crystal X-ray interferometer was studied aiming at in vivo observation in the future. In a preliminary study, the two-crystal X-ray interferometer was capable of generating fringes of 70% visibility using synchrotron X-rays

  8. The study of interferometer spectrometer based on DSP and linear CCD

    Science.gov (United States)

    Kang, Hua; Peng, Yuexiang; Xu, Xinchen; Xing, Xiaoqiao

    2010-11-01

    In this paper, general theory of Fourier-transform spectrometer and polarization interferometer is presented. A new design is proposed for Fourier-transform spectrometer based on polarization interferometer with Wollaston prisms and linear CCD. Firstly, measured light is changed into linear polarization light by polarization plate. And then the light can be split into ordinary and extraordinary lights by going through one Wollaston prism. At last, after going through another Wollaston prism and analyzer, interfering fringes can be formed on linear CCD behind the analyzer. The linear CCD is driven by CPLD to output amplitude of interfering fringes and synchronous signals of frames and pixels respectively. DSP is used to collect interference pattern signals from CCD and the digital data of interfering fringes are processed by using 2048-point-FFT. Finally, optical spectrum of measured light can be display on LCD connected to DSP with RS232. The spectrometer will possess the features of firmness, portability and the ability of real-time analyzing. The work will provide a convenient and significant foundation for application of more high accuracy of Fourier-transform spectrometer.

  9. A general theory of interference fringes in x-ray phase grating imaging

    International Nuclear Information System (INIS)

    Yan, Aimin; Wu, Xizeng; Liu, Hong

    2015-01-01

    Purpose: The authors note that the concept of the Talbot self-image distance in x-ray phase grating interferometry is indeed not well defined for polychromatic x-rays, because both the grating phase shift and the fractional Talbot distances are all x-ray wavelength-dependent. For x-ray interferometry optimization, there is a need for a quantitative theory that is able to predict if a good intensity modulation is attainable at a given grating-to-detector distance. In this work, the authors set out to meet this need. Methods: In order to apply Fourier analysis directly to the intensity fringe patterns of two-dimensional and one-dimensional phase grating interferometers, the authors start their derivation from a general phase space theory of x-ray phase-contrast imaging. Unlike previous Fourier analyses, the authors evolved the Wigner distribution to obtain closed-form expressions of the Fourier coefficients of the intensity fringes for any grating-to-detector distance, even if it is not a fractional Talbot distance. Results: The developed theory determines the visibility of any diffraction order as a function of the grating-to-detector distance, the phase shift of the grating, and the x-ray spectrum. The authors demonstrate that the visibilities of diffraction orders can serve as the indicators of the underlying interference intensity modulation. Applying the theory to the conventional and inverse geometry configurations of single-grating interferometers, the authors demonstrated that the proposed theory provides a quantitative tool for the grating interferometer optimization with or without the Talbot-distance constraints. Conclusions: In this work, the authors developed a novel theory of the interference intensity fringes in phase grating x-ray interferometry. This theory provides a quantitative tool in design optimization of phase grating x-ray interferometers

  10. A general theory of interference fringes in x-ray phase grating imaging.

    Science.gov (United States)

    Yan, Aimin; Wu, Xizeng; Liu, Hong

    2015-06-01

    The authors note that the concept of the Talbot self-image distance in x-ray phase grating interferometry is indeed not well defined for polychromatic x-rays, because both the grating phase shift and the fractional Talbot distances are all x-ray wavelength-dependent. For x-ray interferometry optimization, there is a need for a quantitative theory that is able to predict if a good intensity modulation is attainable at a given grating-to-detector distance. In this work, the authors set out to meet this need. In order to apply Fourier analysis directly to the intensity fringe patterns of two-dimensional and one-dimensional phase grating interferometers, the authors start their derivation from a general phase space theory of x-ray phase-contrast imaging. Unlike previous Fourier analyses, the authors evolved the Wigner distribution to obtain closed-form expressions of the Fourier coefficients of the intensity fringes for any grating-to-detector distance, even if it is not a fractional Talbot distance. The developed theory determines the visibility of any diffraction order as a function of the grating-to-detector distance, the phase shift of the grating, and the x-ray spectrum. The authors demonstrate that the visibilities of diffraction orders can serve as the indicators of the underlying interference intensity modulation. Applying the theory to the conventional and inverse geometry configurations of single-grating interferometers, the authors demonstrated that the proposed theory provides a quantitative tool for the grating interferometer optimization with or without the Talbot-distance constraints. In this work, the authors developed a novel theory of the interference intensity fringes in phase grating x-ray interferometry. This theory provides a quantitative tool in design optimization of phase grating x-ray interferometers.

  11. Novel Method of Detecting Movement of the Interference Fringes Using One-Dimensional PSD

    Directory of Open Access Journals (Sweden)

    Qi Wang

    2015-06-01

    Full Text Available In this paper, a method of using a one-dimensional position-sensitive detector (PSD by replacing charge-coupled device (CCD to measure the movement of the interference fringes is presented first, and its feasibility is demonstrated through an experimental setup based on the principle of centroid detection. Firstly, the centroid position of the interference fringes in a fiber Mach-Zehnder (M-Z interferometer is solved in theory, showing it has a higher resolution and sensitivity. According to the physical characteristics and principles of PSD, a simulation of the interference fringe’s phase difference in fiber M-Z interferometers and PSD output is carried out. Comparing the simulation results with the relationship between phase differences and centroid positions in fiber M-Z interferometers, the conclusion that the output of interference fringes by PSD is still the centroid position is obtained. Based on massive measurements, the best resolution of the system is achieved with 5.15, 625 μm. Finally, the detection system is evaluated through setup error analysis and an ultra-narrow-band filter structure. The filter structure is configured with a one-dimensional photonic crystal containing positive and negative refraction material, which can eliminate background light in the PSD detection experiment. This detection system has a simple structure, good stability, high precision and easily performs remote measurements, which makes it potentially useful in material small deformation tests, refractivity measurements of optical media and optical wave front detection.

  12. Modeling of the fringe shift in multiple beam interference for glass ...

    Indian Academy of Sciences (India)

    An experiment is conducted using liquid wedge interferometer where the fiber of a nearly quadratic .... For a fringe shift dz < ∆z, we obtain this inequality. µf − µL < λt2 .... [11] L M Boggs, H M Presby and D Marcuse, Bell System Tech. J. 58, 867 ...

  13. A heterodyne interferometer with periodic nonlinearities smaller than ±10 pm

    International Nuclear Information System (INIS)

    Weichert, C; Köchert, P; Köning, R; Flügge, J; Andreas, B; Kuetgens, U; Yacoot, A

    2012-01-01

    The PTB developed a new optical heterodyne interferometer in the context of the European joint research project ‘Nanotrace’. A new optical concept using plane-parallel plates and spatially separated input beams to minimize the periodic nonlinearities was realized. Furthermore, the interferometer has the resolution of a double-path interferometer, compensates for possible angle variations between the mirrors and the interferometer optics and offers a minimal path difference between the reference and the measurement arm. Additionally, a new heterodyne phase evaluation based on an analogue to digital converter board with embedded field programmable gate arrays was developed, providing a high-resolving capability in the single-digit picometre range. The nonlinearities were characterized by a comparison with an x-ray interferometer, over a measurement range of 2.2 periods of the optical interferometer. Assuming an error-free x-ray interferometer, the nonlinearities are considered to be the deviation of the measured displacement from a best-fit line. For the proposed interferometer, nonlinearities smaller than ±10 pm were observed without any quadrature fringe correction. (paper)

  14. A heterodyne interferometer with periodic nonlinearities smaller than ±10 pm

    Science.gov (United States)

    Weichert, C.; Köchert, P.; Köning, R.; Flügge, J.; Andreas, B.; Kuetgens, U.; Yacoot, A.

    2012-09-01

    The PTB developed a new optical heterodyne interferometer in the context of the European joint research project ‘Nanotrace’. A new optical concept using plane-parallel plates and spatially separated input beams to minimize the periodic nonlinearities was realized. Furthermore, the interferometer has the resolution of a double-path interferometer, compensates for possible angle variations between the mirrors and the interferometer optics and offers a minimal path difference between the reference and the measurement arm. Additionally, a new heterodyne phase evaluation based on an analogue to digital converter board with embedded field programmable gate arrays was developed, providing a high-resolving capability in the single-digit picometre range. The nonlinearities were characterized by a comparison with an x-ray interferometer, over a measurement range of 2.2 periods of the optical interferometer. Assuming an error-free x-ray interferometer, the nonlinearities are considered to be the deviation of the measured displacement from a best-fit line. For the proposed interferometer, nonlinearities smaller than ±10 pm were observed without any quadrature fringe correction.

  15. Development of the measurement system with interferometers for ultraprecise X-ray mirror

    CERN Document Server

    Yamauchi, K; Mimura, H

    2003-01-01

    A figure measurement system with a stitching method has been developed for evaluation and fabrication of the ultraprecise hard X-ray mirror optics. This system was constructed by two interferometers. One is the Michelson-type microscopic interferometer which is improved to keep the focus distance within 0.1 mu m. Another is the Fizeau's interferometer employed to compensate stitching error in the long spatial wavelength range. To estimate the absolute accuracy in this figure measurement system, the reflection X-ray intensity distributions of flat and aspherical mirrors, which are fabricated by us, were predicted by wave-optical simulation based on measured profile an compared with actually observed distributions. As the result, they are in good agreements. These agreements prove that the developed system has sub-nanometer absolute accuracy in all the spatial wavelength range longer than 0.5mm, because sub-nanometer figure error in those spatial wavelength ranges are known to affect reflection X-ray intensity ...

  16. Polydyne displacement interferometer using frequency-modulated light

    Science.gov (United States)

    Arablu, Masoud; Smith, Stuart T.

    2018-05-01

    A radio-frequency Frequency-Modulated (FM) signal is used to diffract a He-Ne laser beam through an Acousto-Optic Modulator (AOM). Due to the modulation of the FM signal, the measured spectra of the diffracted beams comprise a series of phase-synchronized harmonics that have exact integer frequency separation. The first diffraction side-beam emerging from the AOM is selected by a slit to be used in a polydyne displacement interferometer in a Michelson interferometer topology. The displacement measurement is derived from the phase measurement of selected modulation harmonic pairs. Individual harmonic frequency amplitudes are measured using discrete Fourier transform applied to the signal from a single photodetector. Phase signals are derived from the changes in the amplitudes of different harmonic pairs (typically odd-even pairs) with the phase being extracted using a standard quadrature method. In this study, two different modulation frequencies of 5 and 10 kHz are used at different modulation depths. The measured displacements by different harmonic pairs are compared with a commercial heterodyne interferometer being used as a reference for these studies. Measurements obtained from five different harmonic pairs when the moving mirror of the interferometer is scanned over ranges up to 10 μm all show differences of less than 50 nm from the reference interferometer measurements. A drift test was also used to evaluate the differences between the polydyne interferometer and reference measurements that had different optical path lengths of approximately 25 mm and 50 mm, respectively. The drift test results indicate that about half of the differences can be attributed to temperature, pressure, and humidity variations. Other influences include Abbe and thermal expansion effects. Rough magnitude estimates using simple models for these two effects can account for remaining observed deviations.

  17. Studies of end loss from a theta pinch using a Twyman--Green interferometer. Scientific report 77-4

    International Nuclear Information System (INIS)

    Freeman, R.S.

    1977-11-01

    The transient rate of flow of plasma from the ends of a short, high density, low temperature linear theta pinch was studied experimentally and analytically. Diagnostic devices were used to study the discharge and plasma properties; these included a Rogowski coil, a magnetic field probe and a Twyman-Green double pass interferometer which was illuminated by a 7 mW He--He laser. The interferometer was used to monitor the passage of fringes with respect to time at two radial positions simultaneously by the use of a photodetector consisting of two fast silicon photodiodes with supporting circuitry. One complete fringe represented a change in number density of 2.942 x 10 16 cm -3

  18. Sagnac interferometer as a speed-meter-type, quantum-nondemolition gravitational-wave detector

    International Nuclear Information System (INIS)

    Chen Yanbei

    2003-01-01

    According to quantum measurement theory, 'speed meters' - devices that measure the momentum, or speed, of free test masses - are immune to the standard quantum limit (SQL). It is shown that a Sagnac-interferometer gravitational-wave detector is a speed meter and therefore in principle it can beat the SQL by large amounts over a wide band of frequencies. It is shown, further, that, when one ignores optical losses, a signal-recycled Sag nac interferometer with Fabry-Perot arm cavities has precisely the same performance, for the same circulating light power, as the Michelson speed-meter interferometer recently invented and studied by Purdue and the author. The influence of optical losses is not studied, but it is plausible that they be fairly unimportant for the Sag nac interferometer, as for other speed meters. With squeezed vacuum (squeeze factor e -2R =0.1) injected into its dark port, the recycled Sag nac interferometer can beat the SQL by a factor √(10)≅3 over the frequency band 10 Hz c ∼820 kw as is to be used by the (quantum limited) second-generation Advanced LIGO interferometers--if other noise sources are made sufficiently small. It is concluded that the Sag nac optical configuration, with signal recycling and squeezed-vacuum injection, is an attractive candidate for third-generation interferometric gravitational-wave detectors (LIGO-III and EURO)

  19. A Fiber-Optic Sensor for Leak Detection in a Space Environment

    Science.gov (United States)

    Sinko, John E.; Korman, Valentin; Hendrickson, Adam; Polzin, Kurt A.

    2009-01-01

    A miniature fiber-optic, laser-based, interferometric leak detector is presented for application as a means to detect on-orbit gas leaks. The sensor employs a fiber-coupled modified Michelson interferometer to detect gas leaks by measuring an increase in gas density in the sensing region. Monitoring changes in the fringe pattern output by the interferometer allows for direct measurement of the gas density in the sensing region and, under the assumption of an equation of state, this can be used to obtain a pressure measurement. Measurements obtained over a pressure range from 20 mtorr to 760 torr using a prototypical interferometer on working gases of air, nitrogen, argon, and helium generally exhibit agreement with a theoretical prediction of the pressure increase required before an interference fringe completely moves over the detector. Additional measurements performed on various gases demonstrate the range of detectable species, measuring sub-torr pressure changes in the process. A high-fidelity measurement places the ultimate pressure resolution for this particular sensor configuration in the 10 mtorr range. Time-resolved data prove the capability of this sensor to detect fast gas flow phenomena associated with transients and pressure waves.

  20. VINCI: the VLT Interferometer commissioning instrument

    Science.gov (United States)

    Kervella, Pierre; Coudé du Foresto, Vincent; Glindemann, Andreas; Hofmann, Reiner

    2000-07-01

    The Very Large Telescope Interferometer (VLTI) is a complex system, made of a large number of separated elements. To prepare an early successful operation, it will require a period of extensive testing and verification to ensure that the many devices involved work properly together, and can produce meaningful data. This paper describes the concept chosen for the VLTI commissioning instrument, LEONARDO da VINCI, and details its functionalities. It is a fiber based two-way beam combiner, associated with an artificial star and an alignment verification unit. The technical commissioning of the VLTI is foreseen as a stepwise process: fringes will first be obtained with the commissioning instrument in an autonomous mode (no other parts of the VLTI involved); then the VLTI telescopes and optical trains will be tested in autocollimation; finally fringes will be observed on the sky.

  1. Temperature effects of Mach-Zehnder interferometer using a liquid crystal-filled fiber

    DEFF Research Database (Denmark)

    Ho, Bo-Yan; Su, Hsien-Pin; Tseng, Yu-Pei

    2015-01-01

    We demonstrated a simple and cost-effective method to fabricate all fiber Mach-Zehnder interferometer (MZI) based on cascading a short section of liquid crystal (LC)-filled hollow-optic fiber (HOF) between two single mode fibers by using automatically splicing technique. The transmission spectra...... of the proposed MZI with different LC-infiltrated length were measured and the temperature-induced wavelength shifts of the interference fringes were recorded. Both blue shift and red shift were observed, depending the temperature range. Based on our experimental results, interference fringe was observed...

  2. Pneumatic probe with laser interferometer

    International Nuclear Information System (INIS)

    Wilkens, P.H.

    1978-01-01

    Improvements to upgrade the accuracy of Rotacon probes by a complete redesign of probe to include a Michelson interferometer to replace the existing long-range capacity transducer are described. This has resulted in a compact and interchangeable probe cartridge with a 3 μin. resolution and accuracy; the cartridge can be installed and replaced in the Rotacon gauge with the minimum of realignment, which should reduce our dependence on operator skill. In addition, the stylus contact force can be reduced to 750 mg for the contacting types, but an alternative feature, which we are still developing, will use a gas jet cushion in place of the stylus to provide a noncontacting version of the same basic probe cartridge. This device is very sensitive to external vibration effects because it is virtually frictionless

  3. Highly accurate Michelson type wavelength meter that uses a rubidium stabilized 1560 nm diode laser as a wavelength reference

    International Nuclear Information System (INIS)

    Masuda, Shin; Kanoh, Eiji; Irisawa, Akiyoshi; Niki, Shoji

    2009-01-01

    We investigated the accuracy limitation of a wavelength meter installed in a vacuum chamber to enable us to develop a highly accurate meter based on a Michelson interferometer in 1550 nm optical communication bands. We found that an error of parts per million order could not be avoided using famous wavelength compensation equations. Chromatic dispersion of the refractive index in air can almost be disregarded when a 1560 nm wavelength produced by a rubidium (Rb) stabilized distributed feedback (DFB) diode laser is used as a reference wavelength. We describe a novel dual-wavelength self-calibration scheme that maintains high accuracy of the wavelength meter. The method uses the fundamental and second-harmonic wavelengths of an Rb-stabilized DFB diode laser. Consequently, a highly accurate Michelson type wavelength meter with an absolute accuracy of 5x10 -8 (10 MHz, 0.08 pm) over a wide wavelength range including optical communication bands was achieved without the need for a vacuum chamber.

  4. Speckle and fringe dynamics in imagingspeckle-pattern interferometry for spatial-filtering velocimetry

    DEFF Research Database (Denmark)

    Jakobsen, Michael Linde; Iversen, Theis F. Q.; Yura, Harold T.

    2011-01-01

    This paper analyzes the dynamics of laser speckles and fringes, formed in an imaging-speckle-pattern interferometer with the purpose of sensing linear three-dimensional motion and out-of-plane components of rotation in real time, using optical spatial-filtering-velocimetry techniques. The ensemble......-average definition of the cross-correlation function is applied to the intensity distributions, obtained in the observation plane at two positions of the object. The theoretical analysis provides a description for the dynamics of both the speckles and the fringes. The analysis reveals that both the magnitude...... and direction of all three linear displacement components of the object movement can be determined. Simultaneously, out-ofplane rotation of the object including the corresponding directions can be determined from the spatial gradient of the in-plane fringe motion throughout the observation plane. The theory...

  5. Phase Retrieval Techniques In Coordinates Measurement

    International Nuclear Information System (INIS)

    Harizanova, J. I.; Stoykova, E. V.; Sainov, V. C.

    2007-01-01

    A precise pattern projection profilometry for three-dimensional shape measurements with different methods of fringe generation is presented. The application of phase-shifting algorithm along with two-spacing illumination allow for phase retrieval and estimation of relative and absolute coordinates of the tested samples. The following experimental approaches for fringe generation are investigated: interferometric approach based on a classical Michelson interferometer, digital computation with a DMD projection and light modulation by a sinusoidal phase grating. The theoretical background, experimental results as well as comparison of the applied generation methods are analyzed. The obtained outcomes successfully display the applicability of this technique for surface profile measurement. The application of the proposed techniques for remote, non-destructive in-situ inspection of real objects from cultural heritage is discussed

  6. Turbine blade wear and damage. An overview of advanced characterization techniques

    Energy Technology Data Exchange (ETDEWEB)

    Schlobohm, Jochen; Li, Yinan; Kaestner, Markus; Poesch, Andreas; Reithmeier, Eduard [Hannover Univ. (Germany). Inst. fuer Mess- und Regelungstechnik; Bruchwald, Oliver; Frackowiak, Wojciech; Reimche, Wilfried; Maier, Hans Juergen [Hannover Univ. (Germany). Inst. fuer Werkstoffkunde

    2016-07-01

    This paper gives an overview of four measurement techniques that allow to extensively characterize the status of a worn turbine blade. In addition to the measurement of geometry and surface properties, the condition of the two protective coatings needs to be monitored. Fringe projection was used to detect and quantify geometric variances. The technique was improved using newly developed algorithms like inverse fringe projection. A Michelson interferometer was employed to further analyze areas with geometric defects and characterize the surface morphology of the blade. Pulsed high frequency induction thermography enabled the scanning of the blade for small cracks at or close to the surface. High frequency eddy current testing was used to determine the protective layers status and their thickness.

  7. Compact all-fiber interferometer system for shock acceleration measurement

    Science.gov (United States)

    Zhao, Jiang; Pi, Shaohua; Hong, Guangwei; Zhao, Dong; Jia, Bo

    2013-08-01

    Acceleration measurement plays an important role in a variety of fields in science and engineering. In particular, the accurate, continuous and non-contact recording of the shock acceleration profiles of the free target surfaces is considered as a critical technique in shock physics. Various kinds of optical interferometers have been developed to monitor the motion of the surfaces of shocked targets since the 1960s, for instance, the velocity interferometer system for any reflector, the fiber optic accelerometer, the photonic Doppler velocimetry system and the displacement interferometer. However, most of such systems rely on the coherent quasi-monochromatic illumination and discrete optic elements, which are costly in setting-up and maintenance. In 1996, L. Levin et al reported an interferometric fiber-optic Doppler velocimeter with high-dynamic range, in which fiber-coupled components were used to replace the discrete optic elements. However, the fringe visibility of the Levin's system is low because of the coupled components, which greatly limits the reliability and accuracy in the shock measurement. In this paper, a compact all-fiber interferometer system for measuring the shock acceleration is developed and tested. The advantage of the system is that not only removes the non-interfering light and enhances the fringe visibility, but also reduces polarization induced signal fading and the polarization induced phase shift. Moreover, it also does not require a source of long coherence length. The system bases entirely on single-mode fiber optics and mainly consists of a polarization beam splitter, a faraday rotator, a depolarizer and a 3×3 single-mode fiber coupler which work at 1310 nm wavelength. The optical systems of the interferometer are described and the experimental results compared with a shock acceleration calibration system with a pneumatic exciter (PneuShockTM Model 9525C by The Modal Shop) are reported. In the shock acceleration test, the

  8. CO2 laser interferometer for temporally and spatially resolved electron density measurements

    Science.gov (United States)

    Brannon, P. J.; Gerber, R. A.; Gerardo, J. B.

    1982-09-01

    A 10.6-μm Mach-Zehnder interferometer has been constructed to make temporally and spatially resolved measurements of electron densities in plasmas. The device uses a pyroelectric vidicon camera and video memory to record and display the two-dimensional fringe pattern and a Pockels cell to limit the pulse width of the 10.6-μm radiation. A temporal resolution of 14 ns has been demonstrated. The relative sensitivity of the device for electron density measurements is 2×1015 cm-2 (the line integral of the line-of-sight length and electron density), which corresponds to 0.1 fringe shift.

  9. CO2 laser interferometer for temporally and spatially resolved electron density measurements

    International Nuclear Information System (INIS)

    Brannon, P.J.; Gerber, R.A.; Gerardo, J.B.

    1982-01-01

    A 10.6-μm Mach--Zehnder interferometer has been constructed to make temporally and spatially resolved measurements of electron densities in plasmas. The device uses a pyroelectric vidicon camera and video memory to record and display the two-dimensional fringe pattern and a Pockels cell to limit the pulse width of the 10.6-μm radiation. A temporal resolution of 14 ns has been demonstrated. The relative sensitivity of the device for electron density measurements is 2 x 10 15 cm -2 (the line integral of the line-of-sight length and electron density), which corresponds to 0.1 fringe shift

  10. NAOMI: a low-order adaptive optics system for the VLT interferometer

    Science.gov (United States)

    Gonté, Frédéric Yves J.; Alonso, Jaime; Aller-Carpentier, Emmanuel; Andolfato, Luigi; Berger, Jean-Philippe; Cortes, Angela; Delplancke-Strobele, Françoise; Donaldson, Rob; Dorn, Reinhold J.; Dupuy, Christophe; Egner, Sebastian E.; Huber, Stefan; Hubin, Norbert; Kirchbauer, Jean-Paul; Le Louarn, Miska; Lilley, Paul; Jolley, Paul; Martis, Alessandro; Paufique, Jérôme; Pasquini, Luca; Quentin, Jutta; Ridings, Robert; Reyes, Javier; Shchkaturov, Pavel; Suarez, Marcos; Phan Duc, Thanh; Valdes, Guillermo; Woillez, Julien; Le Bouquin, Jean-Baptiste; Beuzit, Jean-Luc; Rochat, Sylvain; Vérinaud, Christophe; Moulin, Thibaut; Delboulbé, Alain; Michaud, Laurence; Correia, Jean-Jacques; Roux, Alain; Maurel, Didier; Stadler, Eric; Magnard, Yves

    2016-08-01

    The New Adaptive Optics Module for Interferometry (NAOMI) will be developed for and installed at the 1.8-metre Auxiliary Telescopes (ATs) at ESO Paranal. The goal of the project is to equip all four ATs with a low-order Shack- Hartmann adaptive optics system operating in the visible. By improving the wavefront quality delivered by the ATs for guide stars brighter than R = 13 mag, NAOMI will make the existing interferometer performance less dependent on the seeing conditions. Fed with higher and more stable Strehl, the fringe tracker(s) will achieve the fringe stability necessary to reach the full performance of the second-generation instruments GRAVITY and MATISSE.

  11. Performance characterization of a pressure-tuned wide-angle Michelson interferometric spectral filter for high spectral resolution lidar

    Science.gov (United States)

    Seaman, Shane T.; Cook, Anthony L.; Scola, Salvatore J.; Hostetler, Chris A.; Miller, Ian; Welch, Wayne

    2015-09-01

    High Spectral Resolution Lidar (HSRL) is typically realized using an absorption filter to separate molecular returns from particulate returns. NASA Langley Research Center (LaRC) has designed and built a Pressure-Tuned Wide-Angle Michelson Interferometer (PTWAMI) as an alternate means to separate the two types of atmospheric returns. While absorption filters only work at certain wavelengths and suffer from low photon efficiency due to light absorption, an interferometric spectral filter can be designed for any wavelength and transmits nearly all incident photons. The interferometers developed at LaRC employ an air spacer in one arm, and a solid glass spacer in the other. Field widening is achieved by specific design and selection of the lengths and refractive indices of these two arms. The principal challenge in using such an interferometer as a spectral filter for HSRL aboard aircraft is that variations in glass temperature and air pressure cause changes in the interferometer's optical path difference. Therefore, a tuning mechanism is needed to actively accommodate for these changes. The pressure-tuning mechanism employed here relies on changing the pressure in an enclosed, air-filled arm of the interferometer to change the arm's optical path length. However, tuning using pressure will not adjust for tilt, mirror warpage, or thermally induced wavefront error, so the structural, thermal, and optical behavior of the device must be well understood and optimized in the design and manufacturing process. The PTWAMI has been characterized for particulate transmission ratio, wavefront error, and tilt, and shows acceptable performance for use in an HSRL instrument.

  12. Improved synthetic-heterodyne Michelson interferometer vibrometer using phase and gain control feedback.

    Science.gov (United States)

    Galeti, José Henrique; Kitano, Cláudio; Connelly, Michael J

    2015-12-10

    Synthetic-heterodyne demodulation is a useful technique for dynamic displacement and velocity measurement using interferometric sensors as it can provide an output signal which is immune to interferometric drift. With the advent of cost effective, high-speed real-time signal processing systems and software, processing of the complex signals encountered in interferometry has become more feasible. In conventional synthetic-heterodyne demodulation schemes, to obtain the dynamic displacement or vibration of the object under test requires knowledge of the interferometer visibility and also the argument of two Bessel functions. In this paper, a new synthetic-heterodyne demodulation method is described leading to an expression for the dynamic displacement and velocity of the object under test that is significantly less sensitive to the received optical power. In addition, the application of two independent phase and gain feedback loops is used to compensate for the nonideal gain and phase response of the anti-aliasing filter required for the signal acquisition of the received wideband interferometer signal. The efficacy of the improved system is demonstrated by measuring the displacement sensitivity frequency response and linearity of a Piezoelectric Mirror-Shifter (PMS) over a range of 200 Hz-9 kHz. In addition, the system is used to measure the response of the PMS to triangular and impulse type stimuli. The experimental results show excellent agreement with measurements taken using two independent industry standard calibration methods.

  13. Demonstration of a squeezed-light-enhanced power- and signal-recycled Michelson interferometer.

    Science.gov (United States)

    Vahlbruch, Henning; Chelkowski, Simon; Hage, Boris; Franzen, Alexander; Danzmann, Karsten; Schnabel, Roman

    2005-11-18

    We report on the experimental combination of three advanced interferometer techniques for gravitational wave detection, namely, power recycling, detuned signal recycling, and squeezed field injection. For the first time, we experimentally prove the compatibility of especially the latter two. To achieve a broadband nonclassical sensitivity improvement, we applied a filter cavity for compensation of quadrature rotation. The signal-to-noise ratio was improved by up to 2.8 dB beyond the coherent state's shot noise. The complete setup was stably locked for arbitrary times and characterized by injected single-sideband modulation fields.

  14. Multi-dimensional grating interferometer based on fibre-fed measurement heads arranged in Littrow configuration

    Science.gov (United States)

    Šiaudinytė, Lauryna; Molnar, Gabor; Köning, Rainer; Flügge, Jens

    2018-05-01

    Industrial application versatility of interferometric encoders increases the urge to measure several degrees of freedom. A novel grating interferometer containing a commercially available, minimized Michelson interferometer and three fibre-fed measurement heads is presented in this paper. Moreover, the arrangement is designed for simultaneous displacement measurements in two perpendicular planes. In the proposed setup, beam splitters are located in the fibre heads, therefore the grating is separated from the light source and the photo detector, which influence measurement results by generated heat. The operating principle of the proposed system as well as error sources influencing measurement results are discussed in this paper. Further, the benefits and shortcomings of the setup are presented. A simple Littrow-configuration-based design leads to a compact-size interferometric encoder suitable for multidimensional measurements.

  15. Crosstalk Cancellation for a Simultaneous Phase Shifting Interferometer

    Science.gov (United States)

    Olczak, Eugene (Inventor)

    2014-01-01

    A method of minimizing fringe print-through in a phase-shifting interferometer, includes the steps of: (a) determining multiple transfer functions of pixels in the phase-shifting interferometer; (b) computing a crosstalk term for each transfer function; and (c) displaying, to a user, a phase-difference map using the crosstalk terms computed in step (b). Determining a transfer function in step (a) includes measuring intensities of a reference beam and a test beam at the pixels, and measuring an optical path difference between the reference beam and the test beam at the pixels. Computing crosstalk terms in step (b) includes computing an N-dimensional vector, where N corresponds to the number of transfer functions, and the N-dimensional vector is obtained by minimizing a variance of a modulation function in phase shifted images.

  16. Broadband short pulse measurement by autocorrelation with a sum-frequency generation set-up

    International Nuclear Information System (INIS)

    Glotin, F.; Jaroszynski, D.; Marcouille, O.

    1995-01-01

    Previous spectral and laser pulse length measurements carried out on the CLIO FEL at wavelength λ=8.5 μm suggested that very short light pulses could be generated, about 500 fs wide (FWHM). For these measurements a Michelson interferometer with a Te crystal, as a non-linear detector, was used as a second order autocorrelation device. More recent measurements in similar conditions have confirmed that the laser pulses observed are indeed single: they are not followed by other pulses distant by the slippage length Nλ. As the single micropulse length is likely to depend on the slippage, more measurements at different wavelengths would be useful. This is not directly possible with our actual interferometer set-up, based on a phase-matched non-linear crystal. However, we can use the broadband non-linear medium provided by one of our users' experiments: Sum-Frequency Generation over surfaces. With such autocorrelation set-up, interference fringes are no more visible, but this is largely compensated by the frequency range provided. First tests at 8 μm have already been performed to validate the technic, leading to results similar to those obtained with our previous Michelson set-up

  17. Applications of Optical Interferometer Techniques for Precision Measurements of Changes in Temperature, Growth and Refractive Index of Materials

    Directory of Open Access Journals (Sweden)

    Rami Reddy Bommareddi

    2014-05-01

    Full Text Available Optical metrology techniques used to measure changes in thickness; temperature and refractive index are surveyed. Optical heterodyne detection principle and its applications for precision measurements of changes in thickness and temperature are discussed. Theoretical formulations are developed to estimate crystal growth rate, surface roughness and laser cooling/heating of solids. Applications of Michelson and Mach-Zehnder interferometers to measure temperature changes in laser heating of solids are described. A Mach-Zehnder interferometer is used to measure refractive index and concentration variations of solutions in crystal growth experiments. Additionally, fluorescence lifetime sensing and fluorescence ratio method are described for temperature measurement. For all the above techniques, uncertainty calculations are included.

  18. Sagnac interferometer as a speed-meter-type, quantum-nondemolition gravitational-wave detector

    Science.gov (United States)

    Chen, Yanbei

    2003-06-01

    According to quantum measurement theory, “speed meters”—devices that measure the momentum, or speed, of free test masses—are immune to the standard quantum limit (SQL). It is shown that a Sagnac-interferometer gravitational-wave detector is a speed meter and therefore in principle it can beat the SQL by large amounts over a wide band of frequencies. It is shown, further, that, when one ignores optical losses, a signal-recycled Sagnac interferometer with Fabry-Perot arm cavities has precisely the same performance, for the same circulating light power, as the Michelson speed-meter interferometer recently invented and studied by Purdue and the author. The influence of optical losses is not studied, but it is plausible that they be fairly unimportant for the Sagnac interferometer, as for other speed meters. With squeezed vacuum (squeeze factor e-2R=0.1) injected into its dark port, the recycled Sagnac interferometer can beat the SQL by a factor (10)≃3 over the frequency band 10 Hz≲f≲150 Hz using the same circulating power Ic˜820 kW as is to be used by the (quantum limited) second-generation Advanced LIGO interferometers—if other noise sources are made sufficiently small. It is concluded that the Sagnac optical configuration, with signal recycling and squeezed-vacuum injection, is an attractive candidate for third-generation interferometric gravitational-wave detectors (LIGO-III and EURO).

  19. Optimum design of a microwave interferometer for plasma density measurement

    International Nuclear Information System (INIS)

    Lindberg, L.; Eriksson, A.

    1980-11-01

    Theoretical and practical problems arising in the application of microwave interferometry to density measurements on transient plasmas are discussed. The conditions for unambiquous measurements in a density range as wide as possible are analyzed. It is shown that the initial zero adjustment of the interferometer bridge recommended in many text books is the worst possible choice of initial condition when the aim is high initial sensitivity at low densities. The analytic expressions needed for unambiquous evaluation of any phase shift from a few degrees to several times π (counting of fringes) are derived. The practical design of the interferometer circuit and its inherent error sources due to reflexions and non-ideal component properties are discussed. The results are applied to an interferometer operating at 80 GHz used on a pulsed plasma experiment. The minimum measurable phase shift is 2deg and the range of linear densities that have been measured is = 1 . 10 16 - 3 . 10 18 m -2

  20. First 2.2 micrometer results from the iota interferometer

    Science.gov (United States)

    Dyck, H. M.; Benson, J. A.; Carlton, N. P.; Coldwell, C.; Lacasse, M. G.; Nisenson, P.; Panasyuk, A.; Papaliolios, C.; Pearlman, R. D.; Reasenberg, R. D.

    1995-01-01

    We present the first infrared fringe visibility measurements made with the Infrared Optical Telescope Array on Mt. Hopkins. Effective temperatures are derived for RX Boo, RS Cnc, and Beta Peg. RX Boo is the coolest small-amplitude variable giant star to have an effective temperature determination. We compare the size of its photosphere at infrared wavelengths with the sizes of its SiO and H20 radio emission regions. We also discuss initial performance parameters for the interferometer.

  1. Camera-based micro interferometer for distance sensing

    Science.gov (United States)

    Will, Matthias; Schädel, Martin; Ortlepp, Thomas

    2017-12-01

    Interference of light provides a high precision, non-contact and fast method for measurement method for distances. Therefore this technology dominates in high precision systems. However, in the field of compact sensors capacitive, resistive or inductive methods dominates. The reason is, that the interferometric system has to be precise adjusted and needs a high mechanical stability. As a result, we have usual high-priced complex systems not suitable in the field of compact sensors. To overcome these we developed a new concept for a very small interferometric sensing setup. We combine a miniaturized laser unit, a low cost pixel detector and machine vision routines to realize a demonstrator for a Michelson type micro interferometer. We demonstrate a low cost sensor smaller 1cm3 including all electronics and demonstrate distance sensing up to 30 cm and resolution in nm range.

  2. Magdalena Ridge Observatory Interferometer -- First Light with Telescope 1 and Progress to Fringes

    Science.gov (United States)

    Creech-Eakman, Michelle J.; Haniff, Chris A.; Buscher, David F.; Young, John S.; Payne, Ifan; Romero, Van D.; Magdalena Ridge Observatory Interferometer Team

    2018-01-01

    The Magdalena Ridge Observatory Interferometer (MROI), a 10-telescope optical/near-IR interferometer in central NM has been conceived to be the most ambitious optical interferometric array under construction to date. With baselines ranging from 7.8 to 343 meters, and limiting magnitudes of 14 at K band, it will be able to assess many thousands of astronomical targets on spatial scales of 10's to 0.1's of milliarcseconds. After over a decade of funding from NRL and the major partner institutions (NM Tech and Cambridge University), new funding was obtained in late 2015 via a Cooperative Agreement between NM Tech and the Air Force Research Lab (AFRL) to bring the facility to a three-interferometer system capable of observing geosynchronous satellites. However, we still maintain an exciting and compelling astronomical portfolio which will produce statistical samples of: YSOs and their surrounding disks, systems dominated by mass-loss and mass-transfer, pulsational stars and binary systems, and image the environs of AGN in nearby galaxies. An update on the status and plans for MROI for the next 3 years under the current Cooperative Agreement will be presented. In addition, we will present some examples of observational applications feasible with MROI both in the near-term and as we approach the full 10-telescope facility and describe how the astronomical community can become involved in this exciting project.We wish to acknowledge our sponsors in the NM Congressional Delegation and AFRL FA #9453-15-2-0086 for our recent support.

  3. Nuclear emulsions for the detection of micrometric-scale fringe patterns: an application to positron interferometry

    Science.gov (United States)

    Aghion, S.; Ariga, A.; Bollani, M.; Ereditato, A.; Ferragut, R.; Giammarchi, M.; Lodari, M.; Pistillo, C.; Sala, S.; Scampoli, P.; Vladymyrov, M.

    2018-05-01

    Nuclear emulsions are capable of very high position resolution in the detection of ionizing particles. This feature can be exploited to directly resolve the micrometric-scale fringe pattern produced by a matter-wave interferometer for low energy positrons (in the 10–20 keV range). We have tested the performance of emulsion films in this specific scenario. Exploiting silicon nitride diffraction gratings as absorption masks, we produced periodic patterns with features comparable to the expected interferometer signal. Test samples with periodicities of 6, 7 and 20 μ m were exposed to the positron beam, and the patterns clearly reconstructed. Our results support the feasibility of matter-wave interferometry experiments with positrons.

  4. Fringe wetlands

    International Nuclear Information System (INIS)

    Lugo, A.E.

    1990-01-01

    Fringe wetlands are characterized by the dominance of few species, a clear species zonation, synchrony of ecological processes with episodic events, and simplicity in the structure of vegetation. The structure and ecosystem dynamics of fringe forested wetlands are presented with emphasis on saltwater wetlands because they have been studied more than freshwater ones. The study areas were Caribbean and Florida mangroves. Fringe wetlands are found on the water edge of oceans, inland estuaries, and lakes. Water motion in the fringe is bi-directional and perpendicular to the forest and due mostly to tidal energy in oceanic and estuarine fringes. in lakes, water moves in and out of the fringe under the influence of wind, waves, or seiches. some fringe forests are occasionally flushed by terrestrial runoff or aquifer discharge. In contrast, fringe forests located on small offshore islands or steep coastal shroes are isolated from terrestrial runoff or aquifer discharge, and their hydroperiod is controlled by tides and waves only. Literature reviews suggest that ecosystem parameters such as vegetation structure, tree growth, primary productivity, and organic matter in sediments respond proportionally to hydrologic energy. Human activity that impacts on fringe forested wetlands include harvesting of trees, oil pollution and eutrophication. 72 refs., 12 figs., 9 tabs

  5. A new high sensitivity far-infrared laser interferometer for the HL-2A tokamak

    Science.gov (United States)

    Li, Y. G.; Zhou, Y.; Li, Y.; Deng, Z. C.; Wang, H. X.; Yi, J.

    2017-08-01

    A new four-chord Michelson-type formic acid (HCOOH, λ = 432.5 μm) laser interferometer has been successfully commissioned on the HL-2A tokamak to measure the electron density and density fluctuations. Due to the employment of the two-laser heterodyne technique, the time resolution of the interferometer reached 1.0 microseconds (μs). Four chords of line electron densities with a line-averaged density resolution 2 × 1016/m3 were obtained in a recent HL-2A experimental campaign, and detailed electron density fluctuations, caused by events such as edge localized mode, sawtooth precursor-oscillations, and energetic particle driven instabilities, were distinctly measured. In particular, the high-frequency electron density fluctuations (up to 500 kHz) caused by the reversed shear Alfvénic eigenmode were observed by the internal two interferometry channels, and their fluctuation location could be approximately identified from the spectra characteristics of multi-chord line electron densities.

  6. Feasibility evaluation of a neutron grating interferometer with an analyzer grating based on a structured scintillator

    Science.gov (United States)

    Kim, Youngju; Kim, Jongyul; Kim, Daeseung; Hussey, Daniel. S.; Lee, Seung Wook

    2018-03-01

    We introduce an analyzer grating based on a structured scintillator fabricated by a gadolinium oxysulfide powder filling method for a symmetric Talbot-Lau neutron grating interferometer. This is an alternative way to analyze the Talbot self-image of a grating interferometer without using an absorption grating to block neutrons. Since the structured scintillator analyzer grating itself generates the signal for neutron detection, we do not need an additional scintillator screen as an absorption analyzer grating. We have developed and tested an analyzer grating based on a structured scintillator in our symmetric Talbot-Lau neutron grating interferometer to produce high fidelity absorption, differential phase, and dark-field contrast images. The acquired images have been compared to results of a grating interferometer utilizing a typical absorption analyzer grating with two commercial scintillation screens. The analyzer grating based on the structured scintillator enhances interference fringe visibility and shows a great potential for economical fabrication, compact system design, and so on. We report the performance of the analyzer grating based on a structured scintillator and evaluate its feasibility for the neutron grating interferometer.

  7. Michelson wide-field stellar interferometry : Principles and experimental verification

    NARCIS (Netherlands)

    Montilla, I.; Pereira, S.F.; Braat, J.J.M.

    2005-01-01

    A new interferometric technique for Michelson wide-field interferometry is presented that consists of a Michelson pupil-plane combination scheme in which a wide field of view can be achieved in one shot. This technique uses a stair-shaped mirror in the intermediate image plane of each telescope in

  8. Optimal fringe angle selection for digital fringe projection technique.

    Science.gov (United States)

    Wang, Yajun; Zhang, Song

    2013-10-10

    Existing digital fringe projection (DFP) systems mainly use either horizontal or vertical fringe patterns for three-dimensional shape measurement. This paper reveals that these two fringe directions are usually not optimal where the phase change is the largest to a given depth variation. We propose a novel and efficient method to determine the optimal fringe angle by projecting a set of horizontal and vertical fringe patterns onto a step-height object and by further analyzing two resultant phase maps. Experiments demonstrate the existence of the optimal angle and the success of the proposed optimal angle determination method.

  9. Phase unwrapping algorithm based on multi-frequency fringe projection and fringe background for fringe projection profilometry

    International Nuclear Information System (INIS)

    Zhang, Chunwei; Zhao, Hong; Gu, Feifei; Ma, Yueyang

    2015-01-01

    A phase unwrapping algorithm specially designed for the phase-shifting fringe projection profilometry (FPP) is proposed. It combines a revised dual-frequency fringe projectionalgorithm and a proposed fringe background based quality guided phase unwrapping algorithm (FB-QGPUA). Phase demodulated from the high-frequency fringe patterns is partially unwrapped by that demodulated from the low-frequency ones. Then FB-QGPUA is adopted to further unwrap the partially unwrapped phase. Influences of the phase error on the measurement are researched. Strategy to select the fringe pitch is given. Experiments demonstrate that the proposed method is very robust and efficient. (paper)

  10. Measurement of Local Gravity via a Cold Atom Interferometer

    International Nuclear Information System (INIS)

    Zhou Lin; Xiong Zong-Yuan; Yang Wei; Tang Biao; Peng Wen-Cui; Wang Yi-Bo; Xu Peng; Wang Jin; Zhan Ming-Sheng

    2011-01-01

    We demonstrate a precision measurement of local gravity acceleration g in Wuhan by a compact cold atom interferometer. The atom interferometer is in vertical Mach—Zehnder configuration realized using a π/2 - π - π/2 Raman pulse sequence. Cold atoms were prepared in a magneto-optical trap, launched upward to form an atom fountain, and then coherently manipulated to interfere by stimulated Raman transition. Population signal vs Raman laser phase was recorded as interference fringes, and the local gravity was deduced from the interference signal. We have obtained a resolution of 7 × 10 −9 g after an integration time of 236s under the best vibrational environment conditions. The absolute g value was derived from the chirp rate with a difference of 1.5 × 10 −7 g compared to the gravity reference value. The tidal phenomenon was observed by continuously monitoring the local gravity over 123 h. (atomic and molecular physics)

  11. X-ray wavefront characterization using a rotating shearing interferometer technique.

    Science.gov (United States)

    Wang, Hongchang; Sawhney, Kawal; Berujon, Sébastien; Ziegler, Eric; Rutishauser, Simon; David, Christian

    2011-08-15

    A fast and accurate method to characterize the X-ray wavefront by rotating one of the two gratings of an X-ray shearing interferometer is described and investigated step by step. Such a shearing interferometer consists of a phase grating mounted on a rotation stage, and an absorption grating used as a transmission mask. The mathematical relations for X-ray Moiré fringe analysis when using this device are derived and discussed in the context of the previous literature assumptions. X-ray beam wavefronts without and after X-ray reflective optical elements have been characterized at beamline B16 at Diamond Light Source (DLS) using the presented X-ray rotating shearing interferometer (RSI) technique. It has been demonstrated that this improved method allows accurate calculation of the wavefront radius of curvature and the wavefront distortion, even when one has no previous information on the grating projection pattern period, magnification ratio and the initial grating orientation. As the RSI technique does not require any a priori knowledge of the beam features, it is suitable for routine characterization of wavefronts of a wide range of radii of curvature. © 2011 Optical Society of America

  12. A real time 155 GHz millimeter wave interferometer module for electron density measurement in large plasma devices

    International Nuclear Information System (INIS)

    Huettemann, P.W.; Waidmann, G.

    1982-09-01

    A homodyne, real time 155 GHz interferometer channel is described which is one module of a multichannel system for use on TEXTOR tokamak. A standing sine wave is generated in a phase bridge by transmitting a frequency modulated millimeter wave down two unequal interferometer branches. The presence of plasma produces a phase slip of the sine wave with respect to a reference signal. The phase shift is linear proportional to plasma density for expected TEXTOR plasmas. Long plasma paths give multiradian phase shifts which are recorded by a digital fringe counting system. The accuracy of phase measurement is ΔPHI = 2π/16. Phase changes of 7π/8 are accepted per modulation period. The microwave in the measurement branch of the interferometer is transmitted using a quasioptical technique. Components and technical details are described. The interferometer was tested in a simulation set-up and in two different plasma experiments. Experimental results are presented. (orig.)

  13. Phase extraction based on iterative algorithm using five-frame crossed fringes in phase measuring deflectometry

    Science.gov (United States)

    Jin, Chengying; Li, Dahai; Kewei, E.; Li, Mengyang; Chen, Pengyu; Wang, Ruiyang; Xiong, Zhao

    2018-06-01

    In phase measuring deflectometry, two orthogonal sinusoidal fringe patterns are separately projected on the test surface and the distorted fringes reflected by the surface are recorded, each with a sequential phase shift. Then the two components of the local surface gradients are obtained by triangulation. It usually involves some complicated and time-consuming procedures (fringe projection in the orthogonal directions). In addition, the digital light devices (e.g. LCD screen and CCD camera) are not error free. There are quantization errors for each pixel of both LCD and CCD. Therefore, to avoid the complex process and improve the reliability of the phase distribution, a phase extraction algorithm with five-frame crossed fringes is presented in this paper. It is based on a least-squares iterative process. Using the proposed algorithm, phase distributions and phase shift amounts in two orthogonal directions can be simultaneously and successfully determined through an iterative procedure. Both a numerical simulation and a preliminary experiment are conducted to verify the validity and performance of this algorithm. Experimental results obtained by our method are shown, and comparisons between our experimental results and those obtained by the traditional 16-step phase-shifting algorithm and between our experimental results and those measured by the Fizeau interferometer are made.

  14. Maurice Car̊me'i lihtsad laulud lastele / Helle Michelson

    Index Scriptorium Estoniae

    Michelson, Helle, 1929-

    2003-01-01

    Car̊me, Maurice. Muinasjutud Caprine'ile / tõlkinud Helle Michelson. [Tallinn] : Tiritamm, 2002 ; Car̊me, Maurice. Naeruhull kirsipuu : [luuletused] / prantsuse keelest tõlkinud Helvi Jürisson. [Tallinn] : Tiritamm, 2002 ; Car̊me, Maurice. Margareetapäev : [jutustused] / tõlkinud Helle Michelson. [Tallinn] : Varrak, 2000

  15. Iodine-frequency-stabilized laser diode and displacement-measuring interferometer based on sinusoidal phase modulation

    Science.gov (United States)

    Duong, Quang Anh; Vu, Thanh Tung; Higuchi, Masato; Wei, Dong; Aketagawa, Masato

    2018-06-01

    We propose a sinusoidal phase modulation method to achieve both the frequency stabilization of an external-cavity laser diode (ECLD) to an 127I2 saturated absorption transition near 633 nm and displacement measurement using a Mach–Zehnder interferometer. First, the frequency of the ECLD is stabilized to the b 21 hyperfine component of the P(33) 6-3 transition of 127I2 by combining sinusoidal phase modulation by an electro-optic modulator and frequency modulation spectroscopy by chopping the pump beam using an acousto-optic modulator. Even though a small modulation index of m  =  3.768 rad is utilized, a relative frequency stability of 10‑11 order is obtained over a sampling time of 400 s. Secondly, the frequency-stabilized ECLD is applied as a light source to a Mach–Zehnder interferometer. From the two consecutive modulation harmonics (second and third orders) involved in the interferometer signal, the displacement of the moving mirror is determined for four optical path differences (L 0  =  100, 200, 500, and 1000 mm). The measured modulation indexes for the four optical path differences coincide with the designated value (3.768 rad) within 0.5%. Compared with the sinusoidal frequency modulation Michelson interferometer (Vu et al 2016 Meas. Sci. Technol. 27 105201) which was demonstrated by some of the same authors of this paper, the phase modulation Mach–Zhender interferometer could fix the modulation index to a constant value for the four optical path differences. In this report, we discuss the measurement principle, experimental system, and results.

  16. Precision improvement of frequency-modulated continuous-wave laser ranging system with two auxiliary interferometers

    Science.gov (United States)

    Shi, Guang; Wang, Wen; Zhang, Fumin

    2018-03-01

    The measurement precision of frequency-modulated continuous-wave (FMCW) laser distance measurement should be proportional to the scanning range of the tunable laser. However, the commercial external cavity diode laser (ECDL) is not an ideal tunable laser source in practical applications. Due to the unavoidable mode hopping and scanning nonlinearity of the ECDL, the measurement precision of FMCW laser distance measurements can be substantially affected. Therefore, an FMCW laser ranging system with two auxiliary interferometers is proposed in this paper. Moreover, to eliminate the effects of ECDL, the frequency-sampling method and mode hopping influence suppression method are employed. Compared with a fringe counting interferometer, this FMCW laser ranging system has a measuring error of ± 20 μm at the distance of 5.8 m.

  17. Design requirements for the SWIFT instrument

    International Nuclear Information System (INIS)

    Rahnama, P; McDade, I; Shepherd, G; Gault, W

    2013-01-01

    The Stratospheric Wind Interferometer for Transport studies (SWIFT) instrument is a proposed limb-viewing satellite instrument that employs the method of Doppler Michelson interferometry to measure stratospheric wind velocities and ozone densities in the altitude range of 15–45 km. The values of the main instrument parameters including filter system parameters and Michelson interferometer parameters are derived using simulations and analyses. The system design requirements for the instrument and spacecraft are presented and discussed. Some of the retrieval-imposed design requirements are also discussed. Critical design issues are identified. The design optimization process is described. The sensitivity of wind measurements to instrument characteristics is investigated including the impact on critical design issues. Using sensitivity analyses, the instrument parameters were iteratively optimized in order to meet the science objectives. It is shown that wind measurements are sensitive to the thermal sensitivity of the instrument components, especially the narrow filter and the Michelson interferometer. The optimized values of the main system parameters including Michelson interferometer optical path difference, instrument visibility, instrument responsivity and knowledge of spacecraft velocity are reported. This work also shows that the filter thermal drift and the Michelson thermal drift are two main technical risks. (paper)

  18. Focused-laser interferometric position sensor

    International Nuclear Information System (INIS)

    Friedman, Stephen J.; Barwick, Brett; Batelaan, Herman

    2005-01-01

    We describe a simple method to measure the position shifts of an object with a range of tens of micrometers using a focused-laser (FL) interferometric position sensor. In this article we examine the effects of mechanical vibration on FL and Michelson interferometers. We tested both interferometers using vibration amplitudes ranging from 0 to 20 μm. Our FL interferometer has a resolution much better than the diffraction grating periodicities of 10 and 14 μm used in our experiments. A FL interferometer provides improved mechanical stability at the expense of spatial resolution. Our experimental results show that Michelson interferometers cannot be used when the vibration amplitude is more than an optical wavelength. The main purpose of this article is to demonstrate that a focused-laser interferometric position sensor can be used to measure the position shifts of an object on a less sensitive, micrometer scale when the vibration amplitude is too large to use a Michelson interferometer

  19. Lembit Michelsoni CV / Lembit Michelson

    Index Scriptorium Estoniae

    Michelson, Lembit, 1960-

    2011-01-01

    Fotograaf Lembit Michelson meenutab lapsepõlve- ja kooliaastaid, sõjaväeteenistust, tööd fotograafina nõukogude ajal. Viimased 15 aastat töötab oma foto- ja disainistuudios Akriibia. Erinevatest fotoseeriatest. Artiklile lisatud 7 Lembit Michelsoni kirjutatud luuletust

  20. Fourier emission infrared microspectrophotometer for surface analysis. I - Application to lubrication problems

    Science.gov (United States)

    Lauer, J. L.; King, V. W.

    1979-01-01

    A far-infrared interferometer was converted into an emission microspectrophotometer for surface analysis. To cover the mid-infrared as well as the far-infrared the Mylar beamsplitter was made replaceable by a germanium-coated salt plate, and the Moire fringe counting system used to locate the moveable Michelson mirror was improved to read 0.5 micron of mirror displacement. Digital electronics and a dedicated minicomputer were installed for data collection and processing. The most critical element for the recording of weak emission spectra from small areas was, however, a reflecting microscope objective and phase-locked signal detection with simultaneous referencing to a blackbody source. An application of the technique to lubrication problems is shown.

  1. Opto-acoustic technique to evaluate adhesion strength of thin-film systems

    Directory of Open Access Journals (Sweden)

    S. Yoshida

    2012-06-01

    Full Text Available An opto-acoustic technique is proposed to evaluate the adhesion strength of thin film systems at the film-substrate interface. The thin-film system to be examined is configured as an end-mirror of a Michelson interferometer, and driven from the rear with an acoustic transducer at audible frequencies. The amplitude of the resultant oscillation of the film is quantified as the variation in the contrast of the interferometric fringe pattern observed with a digital camera at 30 frames/s. As a proof of concept, experiment has been conducted with the use of a pair of strongly and weakly adhered Au-coated Si-wafer specimens. The technique successfully differentiates the adhesion strength of the specimens.

  2. Fringe-period selection for a multifrequency fringe-projection phase unwrapping method

    International Nuclear Information System (INIS)

    Zhang, Chunwei; Zhao, Hong; Jiang, Kejian

    2016-01-01

    The multi-frequency fringe-projection phase unwrapping method (MFPPUM) is a typical phase unwrapping algorithm for fringe projection profilometry. It has the advantage of being capable of correctly accomplishing phase unwrapping even in the presence of surface discontinuities. If the fringe frequency ratio of the MFPPUM is too large, fringe order error (FOE) may be triggered. FOE will result in phase unwrapping error. It is preferable for the phase unwrapping to be kept correct while the fewest sets of lower frequency fringe patterns are used. To achieve this goal, in this paper a parameter called fringe order inaccuracy (FOI) is defined, dominant factors which may induce FOE are theoretically analyzed, a method to optimally select the fringe periods for the MFPPUM is proposed with the aid of FOI, and experiments are conducted to research the impact of the dominant factors in phase unwrapping and demonstrate the validity of the proposed method. Some novel phenomena are revealed by these experiments. The proposed method helps to optimally select the fringe periods and detect the phase unwrapping error for the MFPPUM. (paper)

  3. The Michelson Era in American Science, 1870--1930

    International Nuclear Information System (INIS)

    Goldberg, S.; Stuewer, R.H.

    1988-01-01

    The articles in this volume relate, in one way or another, to a single experiment: the Michelson-Morley ether-drift experiment of 1887. About one-half of the articles in the collection are based on papers delivered at a two-day symposium ''The Michelson Era in American Science: 1870--1930,'' held a Case Western Reserve University in Cleveland, Ohio, 28--29 October 1987, commemorating the centennial of the experiment. The Michelson-Morley experiment was designed to detect the motion of the earth through the luminiferous ether. At the time, physicists did not question the existence of the ether. The experiment, like many physical probes of nature, was simple in conception, yet uncompromisingly demanding of the art of contemporary craftsmanship. The state of the mechanical arts and its relationship to the pursuit of physical science in late nineteenth- century America is well documented in Section I, which also addresses the more general question of the link between state-of-the-art shop practice and engineering theory

  4. A novel plasmonic interferometry and the potential applications

    Directory of Open Access Journals (Sweden)

    J. Ali

    2018-03-01

    Full Text Available In this article, we have proposed the plasmonic interferometry concept and analytical details given. By using the conventional optical interferometry, which can be simply calculated by using the relationship between the electric field and electron mobility, the interference mobility visibility (fringe visibility can be observed. The surface plasmons in the sensing arm of the Michelson interferometer is constructed by the stacked layers of the silicon-graphene-gold, allows to characterize the spatial resolution of light beams in terms of the electron mobility down to 100-nm scales, with measured coherence lengths as low as ∼100 nm for an incident wavelength of 1550 nm. We have demonstrated a compact plasmonic interferometer that can apply to the electron mean free paths measurement, from which the precise determination can be used for the high-resolution mean free path measurement and sensing applications. This system provides the practical simulation device parameters that can be fabricated and tested by the experimental platform.

  5. A novel plasmonic interferometry and the potential applications

    Science.gov (United States)

    Ali, J.; Pornsuwancharoen, N.; Youplao, P.; Aziz, M. S.; Chiangga, S.; Jaglan, J.; Amiri, I. S.; Yupapin, P.

    2018-03-01

    In this article, we have proposed the plasmonic interferometry concept and analytical details given. By using the conventional optical interferometry, which can be simply calculated by using the relationship between the electric field and electron mobility, the interference mobility visibility (fringe visibility) can be observed. The surface plasmons in the sensing arm of the Michelson interferometer is constructed by the stacked layers of the silicon-graphene-gold, allows to characterize the spatial resolution of light beams in terms of the electron mobility down to 100-nm scales, with measured coherence lengths as low as ∼100 nm for an incident wavelength of 1550 nm. We have demonstrated a compact plasmonic interferometer that can apply to the electron mean free paths measurement, from which the precise determination can be used for the high-resolution mean free path measurement and sensing applications. This system provides the practical simulation device parameters that can be fabricated and tested by the experimental platform.

  6. Noise Studies of Externally Dispersed Interferometry for Doppler Velocimetry

    International Nuclear Information System (INIS)

    Erskine, D J; Edelstein, J; Lloyd, J; Muirhead, P

    2006-01-01

    Externally Dispersed Interferometry (EDI) is the series combination of a fixed-delay field-widened Michelson interferometer with a dispersive spectrograph. This combination boosts the spectrograph performance for both Doppler velocimetry and high resolution spectroscopy. The interferometer creates a periodic comb that multiplies against the input spectrum to create moire fringes, which are recorded in combination with the regular spectrum. Both regular and high-frequency spectral components can be recovered from the data--the moire component carries additional information that increases the signal to noise for velocimetry and spectroscopy. Here we present simulations and theoretical studies of the photon limited Doppler velocity noise in an EDI. We used a model spectrum of a 1600K temperature star. For several rotational blurring velocities 0, 7.5, 15 and 25 km/s we calculated the dimensionless Doppler quality index (Q) versus wavenumber v. This is the normalized RMS of the derivative of the spectrum and is proportional to the photon-limited Doppler signal to noise ratio

  7. Optimization methods of pulse-to-pulse alignment using femtosecond pulse laser based on temporal coherence function for practical distance measurement

    Science.gov (United States)

    Liu, Yang; Yang, Linghui; Guo, Yin; Lin, Jiarui; Cui, Pengfei; Zhu, Jigui

    2018-02-01

    An interferometer technique based on temporal coherence function of femtosecond pulses is demonstrated for practical distance measurement. Here, the pulse-to-pulse alignment is analyzed for large delay distance measurement. Firstly, a temporal coherence function model between two femtosecond pulses is developed in the time domain for the dispersive unbalanced Michelson interferometer. Then, according to this model, the fringes analysis and the envelope extraction process are discussed. Meanwhile, optimization methods of pulse-to-pulse alignment for practical long distance measurement are presented. The order of the curve fitting and the selection of points for envelope extraction are analyzed. Furthermore, an averaging method based on the symmetry of the coherence function is demonstrated. Finally, the performance of the proposed methods is evaluated in the absolute distance measurement of 20 μ m with path length difference of 9 m. The improvement of standard deviation in experimental results shows that these approaches have the potential for practical distance measurement.

  8. Phase-conjugate interferometer to estimate refractive index and thickness of transparent plane parallel plates

    Energy Technology Data Exchange (ETDEWEB)

    Pastrana-Sanchez, R.; Rodriguez-Zurita, G.; Vazquez-Castillo, J. F. [Benemerita Universidad Autonoma de Puebla, Puebla (Mexico)

    2001-04-01

    A technique to estimate the refractive index and thickness of homogeneous plane parallel dielectric plates is proposed using a phase-conjugate interferometer, in which counting of interference fringes is employed. The light beam impinges a tilted plate before it enters a phase-conjugate interferometer, and a count of the fringes passing through a given reference at the observing plane gives the phase changes as a function of tilting angle. The obtained data is fitted to a mathematical model, which leads to the determination of both refractive index and thickness simultaneously. In this letter, experimental data from two interferometers are also discussed for comparison. One with an externally-pumped phase-conjugate mirror achieved with a BSO photorefractive crystal and another one with conventional mirrors. Results show that the phase sensitivity of the phase-conjugate interferometer is not simply twice the corresponding sensitivity of the conventional version. [Spanish] Se propone una tecnica para medir indices de refraccion y espesores de placas dielectricas plano paralelas homogeneas empleando un interferometro con fase conjugada, en el cual se usa el conteo de franjas. El haz luminoso incide en una placa inclinada bajo inspeccion antes de entrar en un interferometro equipado con un espejo conjugador de fase, y se realiza un conteo de las franjas que pasan por determinada referencia en el plano de observacion, proporcionando los cambios de fase en funcion del angulo de inclinacion. Los datos obtenidos se ajustan a un modelo, el cual conduce a la determinacion, tanto del indice de refraccion como del espesor, simultaneamente. En este trabajo se discuten datos experimentales provenientes de dos interferometros para su comparacion. Uno de ellos tiene un espejo conjugador basado en un cristal BSO fotorrefractivo, mientras que el otro es una variante con espejos convencionales. Se muestra que la sensibilidad de fase del interferometro con conjugador de fase no

  9. A Fabry-Pérot interferometer with wire-grid polarizers as beamsplitters at terahertz frequencies

    Science.gov (United States)

    Harrison, H.; Lancaster, A. J.; Konoplev, I. V.; Doucas, G.; Aryshev, A.; Shevelev, M.; Terunuma, N.; Urakawa, J.; Huggard, P. G.

    2018-03-01

    The design of a compact Fabry-Pérot interferometer (FPi) and results of the experimental studies carried out using the device are presented. Our FPi uses freestanding wire-grid polarizers (WGPs) as beamsplitters and is suitable for use at terahertz (THz) frequencies. The FPi was studied at the LUCX facility, KEK, Japan, and an 8 MeV linear electron accelerator was used to generate coherent Smith-Purcell radiation. The FPi was designed to be easy to align and reposition for experiments at linear accelerator facilities. All of the components used were required to have a flat or well understood frequency response in the THz range. The performance of the FPi with WGPs was compared to that of a Michelson interferometer and the FPi is seen to perform well. The effectiveness of the beamsplitters used in the FPi is also investigated. Measurements made with the FPi using WGPs, the preferred beamsplitters, are compared to measurements made with the FPi using silicon wafers as alternative beamsplitters. The FPi performs well with both types of beamsplitter in the frequency range used (0.3-0.5 THz). The successful measurements taken with the FPi demonstrate a compact and adaptable interferometer that is capable of analyzing THz radiation over a broad frequency range. The scheme is particularly well suited for polarization studies of THz radiation produced in an accelerator environment.

  10. Controlling the opto-mechanics of a cantilever in an interferometer via cavity loss

    Energy Technology Data Exchange (ETDEWEB)

    Schmidsfeld, A. von, E-mail: avonschm@uos.de; Reichling, M., E-mail: reichling@uos.de [Fachbereich Physik, Universität Osnabrück, Barbarastraße 7, 49076 Osnabrück (Germany)

    2015-09-21

    In a non-contact atomic force microscope, based on interferometric cantilever displacement detection, the optical return loss of the system is tunable via the distance between the fiber end and the cantilever. We utilize this for tuning the interferometer from a predominant Michelson to a predominant Fabry-Pérot characteristics and introduce the Fabry-Pérot enhancement factor as a quantitative measure for multibeam interference in the cavity. This experimentally easily accessible and adjustable parameter provides a control of the opto-mechanical interaction between the cavity light field and the cantilever. The quantitative assessment of the light pressure acting on the cantilever oscillating in the cavity via the frequency shift allows an in-situ measurement of the cantilever stiffness with remarkable precision.

  11. Fringe order correction for the absolute phase recovered by two selected spatial frequency fringe projections in fringe projection profilometry.

    Science.gov (United States)

    Ding, Yi; Peng, Kai; Yu, Miao; Lu, Lei; Zhao, Kun

    2017-08-01

    The performance of the two selected spatial frequency phase unwrapping methods is limited by a phase error bound beyond which errors will occur in the fringe order leading to a significant error in the recovered absolute phase map. In this paper, we propose a method to detect and correct the wrong fringe orders. Two constraints are introduced during the fringe order determination of two selected spatial frequency phase unwrapping methods. A strategy to detect and correct the wrong fringe orders is also described. Compared with the existing methods, we do not need to estimate the threshold associated with absolute phase values to determine the fringe order error, thus making it more reliable and avoiding the procedure of search in detecting and correcting successive fringe order errors. The effectiveness of the proposed method is validated by the experimental results.

  12. Absolute phase map recovery of two fringe patterns with flexible selection of fringe wavelengths.

    Science.gov (United States)

    Long, Jiale; Xi, Jiangtao; Zhu, Ming; Cheng, Wenqing; Cheng, Rui; Li, Zhongwei; Shi, Yusheng

    2014-03-20

    A novel approach is proposed to unwrap the phase maps of two fringe patterns in fringe pattern projection-based profilometry. In contrast to existing techniques, where spatial frequencies (i.e., the number of fringes on a pattern) of the two fringe patterns must be integers and coprime, the proposed method is applicable for any two fringe patterns with different fringe wavelengths (i.e., the number of pixels in a fringe) and thus provides more flexibility in the use of fringe patterns. Moreover, compared to the existing techniques, the proposed method is simpler in its implementation and has better antierror capability. Theoretical analysis and experiment results are presented to confirm the effectiveness of the proposed method.

  13. Atomic interferometry: construction, characterisation and optimisation of an interferometer. Application to precision measurements

    International Nuclear Information System (INIS)

    Buechner, Matthias

    2010-01-01

    This manuscript describes my research activity in atom interferometry. As an introduction to this domain, we have first described some atom interferometers and their applications. We then describe the atom interferometer we have developed in Toulouse. This is a Mach-Zehnder atom interferometer; the atom source is a thermal supersonic lithium beam and atom manipulation is based on laser diffraction in the Bragg regime. This two interferometer arms are spatially separated, with a maximum distance near 100 μm. The interferometer performances are excellent, with a fringe visibility as large as 84.5 % and a high output flux, thus providing a phase sensitivity of 15 mrad √(Hz). We have used this interferometer for several experiments, with a perturbation applied on only one interferometer arm. When the perturbation is an electric field, we thus measure the electric polarizability of lithium, with an uncertainty 3 times smaller than the best previous measurement. When the perturbation is a gas at low density, we measure the complex refraction index of this gas for lithium atomic waves. If the perturbation is a nano-grating, we measure the complex amplitude of the diffraction zeroth order and this amplitude is very sensitive to the van der Waals interaction of the lithium atom with the nano-grating surface. An important part of this manuscript concerns further developments of our activity. We discuss several improvements of the measurement of the electric polarizability of lithium atom and we hope to access to a precision comparable to the one of the best ab initio calculations of this quantity. We plan to detect a new topological phase, predicted by theory in 1993 but never observed. Finally, we are starting the construction of a second generation atom interferometer, with a slow and intense lithium beam. This new source will give a larger signal and a longer interaction time, thus enabling the detection of considerably weaker perturbations: a fascinating possibility

  14. CO2 laser imaging heterodyne and phase contrast interferometer for density profile and fluctuation measurements in LHD

    International Nuclear Information System (INIS)

    Tanaka, K.; Michael, C.; Akiyama, T.; Kawahata, K.; Ito, Y.; Vyacheslavov, L.N.; Sanin, A.L.; Okajima, S.

    2007-01-01

    A CO 2 laser heterodyne imaging interferometer (CO 2 HI) and a CO 2 laser phase contrast imaging interferometer (CO 2 PCI) were installed in LHD. The purpose of CO 2 HI is to measure electron density profile at high density (>1x10 20 m -3 ), where the existing far infrared laser (wavelength 118.9 μm) interferometer suffers from fringe jump due to the reduction of signal intensity caused by refraction. In the beginning of 10th LHD experimental campaign (2006-2007), sixty three three of CO 2 HI with 10 channels of YAG HI for vibration compensation, and in the later of 10th LHD experimental campaign. Eighty one channels CO 2 HI and 15 channels YAG HI became available. The purpose of CO 2 PCI is to measure turbulent fluctuation, which can contribute to the energy and particle transport. In order to get local fluctuation information, magnetic shear technique was applied with use of 48 (6 by 8) channel two dimensional detector. (author)

  15. Combination of a fast white-light interferometer with a phase shifting interferometric line sensor for form measurements of precision components

    Science.gov (United States)

    Laubach, Sören; Ehret, Gerd; Riebling, Jörg; Lehmann, Peter

    2017-06-01

    By means of an interferometric line sensor system, the form of a specimen can be measured by stitching several overlapping circular subapertures to form one 3D topography. This concept is very flexible and can be adapted to many different specimen geometries. The sensor is based on a Michelson interferometer configuration that consists of a rapidly oscillating reference mirror in combination with a high-speed line-scan camera. Due to the overlapping areas, movement errors of the scan axes can be corrected. In order to automatically adjust the line sensor in such a way that it is perpendicular to the measurement surface at a fixed working distance, a white-light interferometer was included in the line-based form-measuring system. By means of a fast white-light scan, the optimum angle of the sensor (with respect to the surface of the specimen) is determined in advance, before scanning the specimen using the line-based sinusoidal phase shifting interferometer. This produces accurate measurement results and makes it possible to also measure non-rotational specimens. In this paper, the setup of the line-based form-measuring system is introduced and the measurement strategy of the sensor adjustment using an additional white-light interferometer is presented. Furthermore, the traceability chain of the system and the main error influences are discussed. Examples of form measurement results are shown.

  16. The design of a second harmonic tangential array interferometer for C-Mod

    International Nuclear Information System (INIS)

    Bretz, N.; Jobes, F.; Irby, J.

    1997-01-01

    A design for a tangential array interferometer for C-Mod operating at 1.06 and 0.53 μm is presented. This is a special type of two color interferometer in which a Nd:YAG laser is frequency doubled in a nonlinear crystal. Because the doubling efficiency is imperfect, two frequencies propagate collinearly through the plasma after which the 1.06 μm ray is doubled again mixing in the optical domain with the undoubled ray. The resulting interference is insensitive to path length but is affected by plasma dispersion in the usual way. A typical central fringe shift in C-Mod is expected to be 0.1 endash 1.0, but the absolute and relative accuracy in n e l measurements can be as high as in a conventional interferometer. This design uses a repetitively pulsed laser which is converted to a fan beam crossing the horizontal midplane. The chordal array is defined by internal retroreflectors on the C-Mod midplane which return the beam to the second doubler and a detector array. This interferometer design has beam diameters of a few millimeters and element spacings of a few centimeters, uses a repetitively pulsed, TEM 00 Nd:YAG laser, fiber optic beam transport, commercial components, and a compact optical design which minimizes port space requirements. An optical system design is presented which is based on the performance of a tabletop prototype at Princeton Plasma Physics Laboratory. copyright 1997 American Institute of Physics

  17. A stellar interferometer on the Moon

    Science.gov (United States)

    Porro, Irene

    is produced by simulating the interference of the distorted wavefront with a plane wavefront. This interferogram is a means to represent the loss in the optical performance of the system. The interferograms produced by the simulation program are collected in an "atlas" (I present an extract of it as an independent appendix of this thesis) which will be used during the telescope alignment operation to help in diagnosing the error in the optics position. The initial part of the chapter is devoted to a brief introduction to the wavefront aberration theory (from Schroeder, 1987) and to the analysis of one of the IOTA telescopes when it is in auto-collimation mode (the configuration used for the alignment operation). On the basis of this analysis I derived the misalignment conditions which I studied by means of the simulation program. The third chapter (III) is devoted to the beamsplitter, a fundamental element for most Michelson optical stellar interferometers. The beamsplitter is the optical element by means of which the beams are made interfere. In the first part of the chapter I describe the characteristics of a beamsplitter for astronomical applications. This description is mainly based on a study that James D. Phillips accomplished within the project of the space interferometer POINTS. To my knowledge, this is the only study which deals with both the theoretical approach of the problem and the experimental aspect involved in the design of a beamsplitter for astronomical applications. In the second part of the chapter I present the original contribution on this subject, which consists in the analysis of the polarizations effects introduced by the beamsplitter. In particular I obtain the expression of the fringe intensity when considering the polarization effects. This expression contains a term which gives the visibility loss due to the phase difference between the polarization components of the interfering beams. Then I evaluate the loss in visibility for IOTA and

  18. Imaging of Stellar Surfaces with the Navy Precision Optical Interferometer

    Science.gov (United States)

    Jorgensen, A.; Schmitt, H. R.; van Belle, G. T.; Hutter, Clark; Mozurkewich, D.; Armstrong, J. T.; Baines, E. K.; Restaino, S. R.

    The Navy Precision Optical Interferometer (NPOI) has a unique layout which is particularly well-suited for high-resolution interferometric imaging. By combining the NPOI layout with a new data acquisition and fringe tracking system we are progressing toward a imaging capability which will exceed any other interferometer in operation. The project, funded by the National Science Foundation, combines several existing advances and infrastructure at NPOI with modest enhancements. For optimal imaging there are several requirements that should be fulfilled. The observatory should be capable of measuring visibilities on a wide range of baseline lengths and orientations, providing complete UV coverage in a short period of time. It should measure visibility amplitudes with good SNR on all baselines as critical imaging information is often contained in low-amplitude visibilities. It should measure the visibility phase on all baselines. The technologies which can achieve this are the NPOI Y-shaped array with (nearly) equal spacing between telescopes and an ability for rapid configuration. Placing 6-telescopes in a row makes it possible to measure visibilities into the 4th lobe of the visibility function. By arranging the available telescopes carefully we will be able to switch, every few days, between 3 different 6-station chains which provide symmetric coverage in the UV (Fourier) plane without moving any telescopes, only by moving beam relay mirrors. The 6-station chains are important to achieve the highest imaging resolution, and switching rapidly between station chains provides uniform coverage. Coherent integration techniques can be used to obtain good SNR on very small visibilities. Coherently integrated visibilities can be used for imaging with standard radio imaging packages such as AIPS. The commissioning of one additional station, the use of new data acquisition hardware and fringe tracking algorithms are the enhancements which make this project possible.

  19. Spatio-temporal phase retrieval in speckle interferometry with Hilbert transform and two-dimensional phase unwrapping

    Science.gov (United States)

    Li, Xiangyu; Huang, Zhanhua; Zhu, Meng; He, Jin; Zhang, Hao

    2014-12-01

    Hilbert transform (HT) is widely used in temporal speckle pattern interferometry, but errors from low modulations might propagate and corrupt the calculated phase. A spatio-temporal method for phase retrieval using temporal HT and spatial phase unwrapping is presented. In time domain, the wrapped phase difference between the initial and current states is directly determined by using HT. To avoid the influence of the low modulation intensity, the phase information between the two states is ignored. As a result, the phase unwrapping is shifted from time domain to space domain. A phase unwrapping algorithm based on discrete cosine transform is adopted by taking advantage of the information in adjacent pixels. An experiment is carried out with a Michelson-type interferometer to study the out-of-plane deformation field. High quality whole-field phase distribution maps with different fringe densities are obtained. Under the experimental conditions, the maximum number of fringes resolvable in a 416×416 frame is 30, which indicates a 15λ deformation along the direction of loading.

  20. Teaching stellar interferometry with polymer optical fibers

    Science.gov (United States)

    Illarramendi, M. A.; Arregui, L.; Zubia, J.; Hueso, R.; Sanchez-Lavega, A.

    2017-08-01

    In this manuscript we show the design of a simple experiment that reproduces the operation of the Michelson stellar interferometer by using step-index polymer optical fibers. The emission of stellar sources, single or binary stars, has been simulated by the laser light emerging from the output surface of the 2 meter-long polymer optical fiber. This light has an emission pattern that is similar to the emission pattern of stellar sources - circular, uniform, spatially incoherent, and quasi-monochromatic. Light coming from the fiber end faces passes through two identical pinholes located on a lid covering the objective of a small telescope, thus producing interference. Interference fringes have been acquired using a camera that is coupled to a telescope. The experiments have been carried out both outdoors in the daytime and indoors. By measuring the fringe visibilities, we have determined the size of our artificial stellar sources and the distance between them, when placing them at distances of 54 m from the telescope in the indoor measurements and of 75 m in the outdoor ones.

  1. Self-noise in interferometers - radio and infrared

    International Nuclear Information System (INIS)

    Kulkarni, S.R.

    1989-01-01

    A complete theory of noise in a synthesis image is proposed for a source of arbitrary strength. In the limit of faint sources, the standard estimates of noise in a synthesis image are recovered, while in the limit of strong sources, the noise in the synthesis image is found to be dominated by either self noise or by the noise generated by the source signal itself. It is found that the best VLBI maps (with noise approaching the thermal noise) may in fact be limited by self noise, and that there is a negligible bias in the standard definitions of the bispectrum phasor and the closure phase. The results suggest that at the low signal levels which are characteristic of infrared interferometers, it is best to fit the model to all the closure phases and fringe amplitudes. 13 refs

  2. Phase retrieval from the phase-shift moiré fringe patterns in simultaneous dual-wavelength interferometry

    Science.gov (United States)

    Cheng, Jinlong; Gao, Zhishan; Bie, Shuyou; Dou, Yimeng; Ni, Ruihu; Yuan, Qun

    2018-02-01

    Simultaneous dual-wavelength interferometry (SDWI) could extend the measured range of each single-wavelength interferometry. The moiré fringe generated in SDWI indirectly represents the information of the measured long synthetic-wavelength ({λ }{{S}}) phase, thus the phase demodulation is rather arduous. To address this issue, we present a method to convert the moiré fringe pattern into a synthetic-wavelength interferogram (moiré to synthetic-wavelength, MTS). After the square of the moiré fringe pattern in the MTS method, the additive moiré pattern is turned into a multiplicative one. And the synthetic-wavelength interferogram could be obtained by a low-pass filtering in spectrum of the multiplicative moiré fringe pattern. Therefore, when the dual-wavelength interferometer is implemented with the π/2 phase shift at {λ }{{S}}, a sequence of synthetic-wavelength phase-shift interferograms with π/2 phase shift could be obtained after the MTS method processing on the captured moiré fringe patterns. And then the synthetic-wavelength phase could be retrieved by the conventional phase-shift algorithm. Compared with other methods in SDWI, the proposed MTS approach could reduce the restriction of the phase shift and frame numbers for the adoption of the conventional phase-shift algorithm. Following, numerical simulations are executed to evaluate the performance of the MTS method in processing time, frames of interferograms and the phase shift error compensation. And the necessary linear carrier for MTS method is less than 0.11 times of the traditional dual-wavelength spatial-domain Fourier transform method. Finally, the deviations for MTS method in experiment are 0.97% for a step with the height of 7.8 μm and 1.11% for a Fresnel lens with the step height of 6.2328 μm.

  3. Fringe pattern denoising via image decomposition.

    Science.gov (United States)

    Fu, Shujun; Zhang, Caiming

    2012-02-01

    Filtering off noise from a fringe pattern is one of the key tasks in optical interferometry. In this Letter, using some suitable function spaces to model different components of a fringe pattern, we propose a new fringe pattern denoising method based on image decomposition. In our method, a fringe image is divided into three parts: low-frequency fringe, high-frequency fringe, and noise, which are processed in different spaces. An adaptive threshold in wavelet shrinkage involved in this algorithm improves its denoising performance. Simulation and experimental results show that our algorithm obtains smooth and clean fringes with different frequencies while preserving fringe features effectively.

  4. Feedback stabilized tandem Fabry-Perot interferometer

    International Nuclear Information System (INIS)

    Fukushima, Hiroyuki; Ito, Mikio; Shirasu, Hiroshi.

    1986-01-01

    A new system for measuring the isotopic ratio of uranium, in which two plane-type Fabry-Perot interferometers (tandem FP) are connected in series. The parallelism between the two FPs is achieved automatically by a feedback control mechanism based on laser interference fringe monitoring. The structure of the tandem FP, feedback control system, automatic parallelism adjustment mechanism and wavelength synchronization mechanism are described in detail. For experiments, a hollow cathode discharge tube of a pulse discharge type is employed. Measurements are made to determine the effects of pulse width on the 238 U peak height of 502.7 nm line, recorder traces of 235 U and 238 U lines, half width for 238 U component of the 502.7 nm line, SN ratio, reproducibility of the 235 U/ 238 U peak height ratio and 235 U/ 238 U intensity ratio. Considerations are made on the spectral line width, contrast, transmission factor, and stability of automatic parallelism control and wavelength synchronization. Results obtained indicates that a single-type interferometer would serve adequately for measuring the 235 U/ 238 U ratio if the automatic parallelism control developed here is used. The ultimate object of the tandem system is to make measurement of 236 U. Satisfactory results have not obtained as yet, but most likely the present system would make it possible if a light source of a higher intensity and advanced photometric techniques are developed. (Nogami, K.)

  5. Development velocity interferometer system for any reflector for measurement of mechanical properties of materials during high strain - rate compression and decompression process

    International Nuclear Information System (INIS)

    Joshi, K.D.; Rav, Amit S.; Gupta, Satish C.

    2011-02-01

    Velocity interferometer system for any reflector (VISAR) has been developed to study the dynamic mechanical properties of materials subjected to high strain rates. This instrument is essentially a wide angle Michelson interferometer for measuring the Doppler shift of the monochromatic light from a laser (in our case λ 0 = 532 nm) after it gets reflected off the free surface of the moving target. A fiber optical arrangement directs the laser beam to the target and transports the scattered light signal into the interferometer. The interferometer beats the light signals reflected from the target at the two different instant of time separated by the delay (τ) decided by the length of the etalon in one of the leg of the interferometer. The interferometer signal is fed to the photomultiplier tube, the output of which is recorded in a digital storage oscilloscope. The oscilloscope record is then analysed to deduce the velocity history of moving free surface of target which is then used to determine various important mechanical properties during high strain rate compression and decompression. This instrument has been used to determine the Hugoniot elastic limit (σ HEL ), spall strength (σ s ) and dynamic yield strength (Y) of Al2024-T4 and SS304 alloys shocked to peak pressures of 4.4 GPa and 12 GPa, respectively in gas gun experiments. The σ HEL , σ s and Y determined from measured free surface velocity profiles of shocked Al2024-T4 target plate are 0.70 GPa, 1.46 GPa and 0.36 GPa, respectively. These values determined for SS304 target plate are 1.35 GPa, 2.6 GPa and 0.8 GPa, respectively. (author)

  6. Switchable multiwavelength fiber laser by using a compact in-fiber Mach–Zehnder interferometer

    International Nuclear Information System (INIS)

    Zhang, Qianwu; Zeng, Xianglong; Pang, Fufei; Wang, Min; Wang, Tingyun

    2012-01-01

    We propose a simple and compact method for implementing an in-fiber Mach–Zehnder interferometer, which is constructed with two optical paths, propagating through the core and the ring-shaped silica cladding modes in the double-cladding fibers. Strong cladding-mode resonance across the thin inner cladding is used to excite the cladding modes. The measured spectra fringe presents high-contrast interference from cascading a pair of well-overlapped resonant spectra dips. In combination with the nonlinear polarization rotation (NPR) technique, switchable and tunable multi-channel laser outputs are experimentally demonstrated with a fluctuation of less than 0.1 dB. (paper)

  7. Testing a Model of Planck-Scale Quantum Geometry With Broadband Correlation of Colocated 40m Interferometers

    International Nuclear Information System (INIS)

    McCuller, Lee Patrick

    2015-01-01

    The Holometer is designed to test for a Planck diffractive-scaling uncertainty in long-baseline position measurements due to an underlying noncommutative geometry normalized to relate Black hole entropy bounds of the Holographic principle to the now-finite number of position states. The experiment overlaps two independent 40 meter optical Michelson interferometers to detect the proposed uncertainty as a common broadband length fluctuation. 150 hours of instrument cross-correlation data are analyzed to test the prediction of a correlated noise magnitude of 7·10 -21 m/√Hz with an effective bandwidth of 750kHz. The interferometers each have a quantum-limited sensitivity of 2.5·10 -18 m/√Hz, but their correlation with a time-bandwidth product of 4·10 11 digs between the noise floors in search for the covarying geometric jitter. The data presents an exclusion of 5 standard deviations for the tested model. This exclusion is defended through analysis of the calibration methods for the instrument as well as further sub shot noise characterization of the optical systems to limit spurious background-correlations from undermining the signal.

  8. Testing a Model of Planck-Scale Quantum Geometry With Broadband Correlation of Colocated 40m Interferometers

    Energy Technology Data Exchange (ETDEWEB)

    McCuller, Lee Patrick [Univ. of Chicago, IL (United States)

    2015-12-01

    The Holometer is designed to test for a Planck diffractive-scaling uncertainty in long-baseline position measurements due to an underlying noncommutative geometry normalized to relate Black hole entropy bounds of the Holographic principle to the now-finite number of position states. The experiment overlaps two independent 40 meter optical Michelson interferometers to detect the proposed uncertainty as a common broadband length fluctuation. 150 hours of instrument cross-correlation data are analyzed to test the prediction of a correlated noise magnitude of $7\\times10^{−21}$ m/$\\sqrt{\\rm Hz}$ with an effective bandwidth of 750kHz. The interferometers each have a quantum-limited sensitivity of $2.5\\times 10^{−18}$ m/$\\sqrt{\\rm Hz}$, but their correlation with a time-bandwidth product of $4\\times 10^{11}$ digs between the noise floors in search for the covarying geometric jitter. The data presents an exclusion of 5 standard deviations for the tested model. This exclusion is defended through analysis of the calibration methods for the instrument as well as further sub shot noise characterization of the optical systems to limit spurious background-correlations from undermining the signal.

  9. Principal-vector-directed fringe-tracking technique.

    Science.gov (United States)

    Zhang, Zhihui; Guo, Hongwei

    2014-11-01

    Fringe tracking is one of the most straightforward techniques for analyzing a single fringe pattern. This work presents a principal-vector-directed fringe-tracking technique. It uses Gaussian derivatives for estimating fringe gradients and uses hysteresis thresholding for segmenting singular points, thus improving the principal component analysis method. Using it allows us to estimate the principal vectors of fringes from a pattern with high noise. The fringe-tracking procedure is directed by these principal vectors, so that erroneous results induced by noise and other error-inducing factors are avoided. At the same time, the singular point regions of the fringe pattern are identified automatically. Using them allows us to determine paths through which the "seed" point for each fringe skeleton is easy to find, thus alleviating the computational burden in processing the fringe pattern. The results of a numerical simulation and experiment demonstrate this method to be valid.

  10. Estimation of fringe orientation for optical fringe patterns with poor quality based on Fourier transform.

    Science.gov (United States)

    Tang, Chen; Wang, Zhifang; Wang, Linlin; Wu, Jian; Gao, Tao; Yan, Si

    2010-02-01

    Fringe orientation represents an important property of fringes. The estimation of orientation from a poor quality fringe image is still a challenging problem faced in this area. This paper introduces a new approach for estimating optical fringe orientation with a poor quality image. This approach is based on the power spectrum analysis of the Fourier transform. We evaluate the performance of this algorithm via application to a variety of test cases and comparison with the widely used gradient-based method and accumulate-differences method. The experimental results show that our method is capable of calculating fringe orientation robustly even when the quality of fringe images is considerably low because of high or low density, high noise, and low contrast. Under the same conditions, our accuracy is even better than that obtained with the gradient-based and accumulate-differences methods, especially for fringe images with poor quality.

  11. Spectral interferometry including the effect of transparent thin films to measure distances and displacements

    International Nuclear Information System (INIS)

    Hlubina, P.

    2004-01-01

    A spectral-domain interferometric technique is applied for measuring mirror distances and displacements in a dispersive Michelson interferometer when the effect of transparent thin films coated onto the interferometer beam splitter and compensator is known. We employ a low-resolution spectrometer in two experiments with different amounts of dispersion in a Michelson interferometer that includes fused-silica optical sample. Knowing the thickness of the optical sample and the nonlinear phase function of the thin films, the positions of the interferometer mirror are determined precisely by a least-squares fitting of the theoretical spectral interferograms to the recorded ones. We compare the results of the processing that include and do not include the effect of transparent thin films (Author)

  12. Simplified absolute phase retrieval of dual-frequency fringe patterns in fringe projection profilometry

    Science.gov (United States)

    Lu, Jin; Mo, Rong; Sun, Huibin; Chang, Zhiyong; Zhao, Xiaxia

    2016-04-01

    In fringe projection profilometry, a simplified method is proposed to recover absolute phase maps of two-frequency fringe patterns by using a unique mapping rule. The mapping rule is designed from the rounded phase values to the fringe order of each pixel. Absolute phase can be recovered by the fringe order maps. Unlike the existing techniques, where the lowest frequency of dual- or multiple-frequency fringe patterns must be single, the presented method breaks the limitation and simplifies the procedure of phase unwrapping. Additionally, due to many issues including ambient light, shadow, sharp edges, step height boundaries and surface reflectivity variations, a novel framework of automatically identifying and removing invalid phase values is also proposed. Simulations and experiments have been carried out to validate the performances of the proposed method.

  13. Simplified fringe order correction for absolute phase maps recovered with multiple-spatial-frequency fringe projections

    International Nuclear Information System (INIS)

    Ding, Yi; Peng, Kai; Lu, Lei; Zhong, Kai; Zhu, Ziqi

    2017-01-01

    Various kinds of fringe order errors may occur in the absolute phase maps recovered with multi-spatial-frequency fringe projections. In existing methods, multiple successive pixels corrupted by fringe order errors are detected and corrected pixel-by-pixel with repeating searches, which is inefficient for applications. To improve the efficiency of multiple successive fringe order corrections, in this paper we propose a method to simplify the error detection and correction by the stepwise increasing property of fringe order. In the proposed method, the numbers of pixels in each step are estimated to find the possible true fringe order values, repeating the search in detecting multiple successive errors can be avoided for efficient error correction. The effectiveness of our proposed method is validated by experimental results. (paper)

  14. Practical speed meter designs for quantum nondemolition gravitational-wave interferometers

    International Nuclear Information System (INIS)

    Purdue, Patricia; Chen Yanbei

    2002-01-01

    In the quest to develop viable designs for third-generation optical interferometric gravitational-wave detectors (e.g., LIGO-III and EURO), one strategy is to monitor the relative momentum or speed of the test-mass mirrors, rather than monitoring their relative position. A previous paper analyzed a straightforward but impractical design for a speed-meter interferometer that accomplishes this. This paper describes some practical variants of speed-meter interferometers. Like the original interferometric speed meter, these designs in principle can beat the gravitational-wave standard quantum limit (SQL) by an arbitrarily large amount, over an arbitrarily wide range of frequencies. These variants essentially consist of a Michelson interferometer plus an extra 'sloshing' cavity that sends the signal back into the interferometer with opposite phase shift, thereby cancelling the position information and leaving a net phase shift proportional to the relative velocity. In practice, the sensitivity of these variants will be limited by the maximum light power W circ circulating in the arm cavities that the mirrors can support and by the leakage of vacuum into the optical train at dissipation points. In the absence of dissipation and with squeezed vacuum (power squeeze factor e -2R ≅0.1) inserted into the output port so as to keep the circulating power down, the SQL can be beat by h/h SQL ∼√(W circ SQL e -2R /W circ ) at all frequencies below some chosen f opt ≅100 Hz. Here W circ SQL ≅800 kW(f opt /100 Hz) 3 is the power required to reach the SQL in the absence of squeezing. (However, as the power increases in this expression, the speed meter becomes more narrow band; additional power and reoptimization of some parameters are required to maintain the wide band. See Sec. III B.) Estimates are given of the amount by which vacuum leakage at dissipation points will debilitate this sensitivity; these losses are 10% or less over most of the frequency range of interest (f

  15. Sensitivity improvement of a laser interferometer limited by inelastic back-scattering, employing dual readout

    International Nuclear Information System (INIS)

    Meinders, Melanie; Schnabel, Roman

    2015-01-01

    Inelastic back-scattering of stray light is a long-standing and fundamental problem in high-sensitivity interferometric measurements and a potential limitation for advanced gravitational-wave (GW) detectors. The emerging parasitic interferences cannot be distinguished from a scientific signal via conventional single readout. In this work, we propose the subtraction of inelastic back-scatter signals by employing dual homodyne detection on the output light, and demonstrate it for a table-top Michelson interferometer. The additional readout contains solely parasitic signals and is used to model the scatter source. Subtraction of the scatter signal reduces the noise spectral density and thus improves the measurement sensitivity. Our scheme is qualitatively different from the previously demonstrated vetoing of scatter signals and opens a new path for improving the sensitivity of future GW detectors and other back-scatter limited devices. (paper)

  16. [Research on lateral shearing interferometer for field monitoring of natural gas pipeline leak].

    Science.gov (United States)

    Zhang, Xue-Feng; Gao, Yu-Bin

    2012-09-01

    Aimed at the mechanical scanning spectroscopy equipment with poor anti-interference and anti-jamming ability, which affects the accuracy of its natural gas pipeline leak detection in the wild, a new type of lateral shearing interferometer system was designed. The system uses a beam splitter to get optical path difference by a mechanical scanning part, and it cancel the introduction of external vibration interference through the linkage between the two beam splitterw. The interference intensity of interference fringes produced was calculated, and analysis of a rotating beam splitter corresponds to the angle of the optical path difference function, solving for the maximum angle of the forward rotation and reverse rotation, which is the maximum optical path range. Experiments using the gas tank deflated simulated natural gas pipeline leak process, in the interference conditions, and the test data of the type WQF530 spectrometer and the new type of lateral shearing interferometer system were comparedt. The experimental results show that the relative error of both systems is about 1% in indoor conditions without interference. However, in interference environment, the error of WQF530 type spectrometer becomes larger, more than 10%, but the error of the new type of lateral shearing interferometer system is still below 5%. The detection accuracy of the type WQF530 spectrometer decreased significantly due to the environment. Therefore, the seismic design of the system can effectively offset power deviation and half-width increases of center wavelength caused by external interference, and compared to conventional mechanical scanning interferometer devices the new system is more suitable for field detection.

  17. Fringe pattern denoising using coherence-enhancing diffusion.

    Science.gov (United States)

    Wang, Haixia; Kemao, Qian; Gao, Wenjing; Lin, Feng; Seah, Hock Soon

    2009-04-15

    Electronic speckle pattern interferometry is one of the methods measuring the displacement on object surfaces in which fringe patterns need to be evaluated. Noise is one of the key problems affecting further processing and reducing measurement quality. We propose an application of coherence-enhancing diffusion to fringe-pattern denoising. It smoothes a fringe pattern along directions both parallel and perpendicular to fringe orientation with suitable diffusion speeds to more effectively reduce noise and improve fringe-pattern quality. It is a generalized work of Tang's et al.'s [Opt. Lett.33, 2179 (2008)] model that only smoothes a fringe pattern along fringe orientation. Since our model diffuses a fringe pattern with an additional direction, it is able to denoise low-density fringes as well as improve denoising effectiveness for high-density fringes. Theoretical analysis as well as simulation and experimental verifications are addressed.

  18. 49 CFR 25.525 - Fringe benefits.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 1 2010-10-01 2010-10-01 false Fringe benefits. 25.525 Section 25.525... Employment in Education Programs or Activities Prohibited § 25.525 Fringe benefits. (a) “Fringe benefits” defined. For purposes of these Title IX regulations, fringe benefits means: Any medical, hospital...

  19. 36 CFR 1211.525 - Fringe benefits.

    Science.gov (United States)

    2010-07-01

    ... 36 Parks, Forests, and Public Property 3 2010-07-01 2010-07-01 false Fringe benefits. 1211.525... Prohibited § 1211.525 Fringe benefits. (a) “Fringe benefits” defined. For purposes of these Title IX regulations, fringe benefits means: Any medical, hospital, accident, life insurance, or retirement benefit...

  20. 22 CFR 229.525 - Fringe benefits.

    Science.gov (United States)

    2010-04-01

    ... 22 Foreign Relations 1 2010-04-01 2010-04-01 false Fringe benefits. 229.525 Section 229.525... Employment in Education Programs or Activities Prohibited § 229.525 Fringe benefits. (a) “Fringe benefits” defined. For purposes of these Title IX regulations, fringe benefits means: Any medical, hospital...

  1. 32 CFR 196.525 - Fringe benefits.

    Science.gov (United States)

    2010-07-01

    ... 32 National Defense 2 2010-07-01 2010-07-01 false Fringe benefits. 196.525 Section 196.525... Prohibited § 196.525 Fringe benefits. (a) “Fringe benefits” defined. For purposes of these Title IX regulations, fringe benefits means: Any medical, hospital, accident, life insurance, or retirement benefit...

  2. 22 CFR 146.525 - Fringe benefits.

    Science.gov (United States)

    2010-04-01

    ... 22 Foreign Relations 1 2010-04-01 2010-04-01 false Fringe benefits. 146.525 Section 146.525... Employment in Education Programs or Activities Prohibited § 146.525 Fringe benefits. (a) “Fringe benefits” defined. For purposes of these Title IX regulations, fringe benefits means: Any medical, hospital...

  3. 28 CFR 54.525 - Fringe benefits.

    Science.gov (United States)

    2010-07-01

    ... 28 Judicial Administration 2 2010-07-01 2010-07-01 false Fringe benefits. 54.525 Section 54.525... in Employment in Education Programs or Activities Prohibited § 54.525 Fringe benefits. (a) “Fringe benefits” defined. For purposes of these Title IX regulations, fringe benefits means: Any medical, hospital...

  4. 10 CFR 1042.525 - Fringe benefits.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false Fringe benefits. 1042.525 Section 1042.525 Energy... Education Programs or Activities Prohibited § 1042.525 Fringe benefits. (a) “Fringe benefits” defined. For purposes of these Title IX regulations, fringe benefits means: Any medical, hospital, accident, life...

  5. 44 CFR 19.525 - Fringe benefits.

    Science.gov (United States)

    2010-10-01

    ... 44 Emergency Management and Assistance 1 2010-10-01 2010-10-01 false Fringe benefits. 19.525... Programs or Activities Prohibited § 19.525 Fringe benefits. (a) “Fringe benefits” defined. For purposes of these Title IX regulations, fringe benefits means: Any medical, hospital, accident, life insurance, or...

  6. Increasing LIGO sensitivity by feedforward subtraction of auxiliary length control noise

    International Nuclear Information System (INIS)

    Meadors, Grant David; Riles, Keith; Kawabe, Keita

    2014-01-01

    LIGO, the Laser Interferometer Gravitational-wave Observatory, has been designed and constructed to measure gravitational wave strain via differential arm length. The LIGO 4 km Michelson arms with Fabry–Perot cavities have auxiliary length control servos for suppressing Michelson motion of the beam-splitter and arm cavity input mirrors, which degrades interferometer sensitivity. We demonstrate how a post facto pipeline improves a data sample from LIGO Science Run 6 with feedforward subtraction. Dividing data into 1024 s windows, we numerically fit filter functions representing the frequency-domain transfer functions from Michelson length channels into the gravitational-wave strain data channel for each window, then subtract the filtered Michelson channel noise (witness) from the strain channel (target). In this paper we describe the algorithm, assess achievable improvements in sensitivity to astrophysical sources, and consider relevance to future interferometry. (paper)

  7. 43 CFR 41.525 - Fringe benefits.

    Science.gov (United States)

    2010-10-01

    ... 43 Public Lands: Interior 1 2010-10-01 2010-10-01 false Fringe benefits. 41.525 Section 41.525... in Employment in Education Programs or Activities Prohibited § 41.525 Fringe benefits. (a) “Fringe benefits” defined. For purposes of these Title IX regulations, fringe benefits means: Any medical, hospital...

  8. 14 CFR 1253.525 - Fringe benefits.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 5 2010-01-01 2010-01-01 false Fringe benefits. 1253.525 Section 1253.525... in Employment in Education Programs or Activities Prohibited § 1253.525 Fringe benefits. (a) “Fringe benefits” defined. For purposes of these Title IX regulations, fringe benefits means: Any medical, hospital...

  9. 6 CFR 17.525 - Fringe benefits.

    Science.gov (United States)

    2010-01-01

    ... 6 Domestic Security 1 2010-01-01 2010-01-01 false Fringe benefits. 17.525 Section 17.525 Domestic... in Employment in Education Programs or Activities Prohibited § 17.525 Fringe benefits. (a) “Fringe benefits” defined. For purposes of these Title IX regulations, the term fringe benefits means any medical...

  10. 10 CFR 5.525 - Fringe benefits.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Fringe benefits. 5.525 Section 5.525 Energy NUCLEAR... Activities Prohibited § 5.525 Fringe benefits. (a) “Fringe benefits” defined. For purposes of these Title IX regulations, fringe benefits means: Any medical, hospital, accident, life insurance, or retirement benefit...

  11. 40 CFR 5.525 - Fringe benefits.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 1 2010-07-01 2010-07-01 false Fringe benefits. 5.525 Section 5.525... in Employment in Education Programs or Activities Prohibited § 5.525 Fringe benefits. (a) “Fringe benefits” defined. For purposes of these Title IX regulations, fringe benefits means: Any medical, hospital...

  12. Variable reflectivity signal mirrors and signal response measurements

    International Nuclear Information System (INIS)

    Vine, Glenn de; Shaddock, Daniel A; McClelland, David E

    2002-01-01

    Future gravitational wave detectors will include some form of signal mirror in order to alter the signal response of the device. We introduce interferometer configurations which utilize a variable reflectivity signal mirror allowing a tunable peak frequency and variable signal bandwidth. A detector configured with a Fabry-Perot cavity as the signal mirror is compared theoretically with one using a Michelson interferometer for a signal mirror. A system for the measurement of the interferometer signal responses is introduced. This technique is applied to a power-recycled Michelson interferometer with resonant sideband extraction. We present broadband measurements of the benchtop prototype's signal response for a range of signal cavity detunings. This technique is also applicable to most other gravitational wave detector configurations

  13. Variable reflectivity signal mirrors and signal response measurements

    CERN Document Server

    Vine, G D; McClelland, D E

    2002-01-01

    Future gravitational wave detectors will include some form of signal mirror in order to alter the signal response of the device. We introduce interferometer configurations which utilize a variable reflectivity signal mirror allowing a tunable peak frequency and variable signal bandwidth. A detector configured with a Fabry-Perot cavity as the signal mirror is compared theoretically with one using a Michelson interferometer for a signal mirror. A system for the measurement of the interferometer signal responses is introduced. This technique is applied to a power-recycled Michelson interferometer with resonant sideband extraction. We present broadband measurements of the benchtop prototype's signal response for a range of signal cavity detunings. This technique is also applicable to most other gravitational wave detector configurations.

  14. 31 CFR 28.525 - Fringe benefits.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 1 2010-07-01 2010-07-01 false Fringe benefits. 28.525 Section 28... the Basis of Sex in Employment in Education Programs or Activities Prohibited § 28.525 Fringe benefits. (a) “Fringe benefits” defined. For purposes of these Title IX regulations, fringe benefits means: Any...

  15. 29 CFR 36.525 - Fringe benefits.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 1 2010-07-01 2010-07-01 true Fringe benefits. 36.525 Section 36.525 Labor Office of the... Activities Prohibited § 36.525 Fringe benefits. (a) “Fringe benefits” defined. For purposes of these Title IX regulations, fringe benefits means: Any medical, hospital, accident, life insurance, or retirement benefit...

  16. ALISEO on MIOSat: an imaging interferometer for earth observation

    Science.gov (United States)

    Barducci, A.; Castagnoli, F.; Castellini, G.; Guzzi, D.; Marcoionni, P.; Pippi, I.

    2017-11-01

    The Italian Space Agency (ASI) decided to perform an low cost Earth observation mission based on a new mini satellite named MIOsat which will carry various technological payloads. Among them an imaging interferometer designed and now ready to be assembled and tested by our Institute. The instrument, named ALISEO (Aerospace Leap-frog Imaging Stationary interferometer for Earth Observation), operates in the common-path Sagnac configuration, and it does not utilize any moving part to scan the phase delays between the two interfering beams. The sensor acquires target images modulated by a pattern of autocorrelation functions of the energy coming from each scene pixel, and the resulting fringe pattern remains spatially fixed with respect to the instrument's field-of-view. The complete interferogram of each target location is retrieved by introducing a relative source-observer motion, which allows any image pixels to be observed under different viewing-angles and experience discrete path differences. The paper describes the main characteristics of the imaging interferometer as well as the overall optical configuration and the electronics layout. Moreover some theoretical issues concerning sampling theory in "common path" imaging interferometry are investigated. The experimental activity performed in laboratory is presented and its outcomes are analysed. Particularly, a set of measurements has been carried out using both standard (certificate) reflectance tiles and natural samples of different volcanic rocks. An algorithm for raw data pre-processing aimed at retrieving the at-sensor radiance spectrum is introduced and its performance is addressed by taking into account various issues such as dark signal subtraction, spectral instrument response compensation, effects of vignetting, and Fourier backtransform. Finally, examples of retrieved absolute reflectance of several samples are sketched at different wavelengths.

  17. Rapid yet accurate measurement of mass diffusion coefficients by phase shifting interferometer

    CERN Document Server

    Guo Zhi Xiong; Komiya, A

    1999-01-01

    The technique of using a phase-shifting interferometer is applied to the study of diffusion in transparent liquid mixtures. A quick method is proposed for determining the diffusion coefficient from the measurements of the location of fringes on a grey level picture. The measurement time is very short (within 100 s) and a very small transient diffusion field can be observed and recorded accurately with a rate of 30 frames per second. The measurement can be completed using less than 0.12 cc of solutions. The influence of gravity on the measurement of the diffusion coefficient is eliminated in the present method. Results on NaCl-water diffusion systems are presented and compared with the reference data. (author)

  18. Application of a hybrid modular acquisition system to the control of a suspended interferometer with electrostatic actuators

    Energy Technology Data Exchange (ETDEWEB)

    Acernese, F; Barone, F; Boiano, A; Rosa, R D; Garufi, F; Milano, L; Mosca, S; Persichetti, G; Romano, R [INFN - Sezione di Napoli, Complesso Universitario di Monte S. Angelo, via Cintia, 80126, Napoli (Italy); Perreca, A [University of Birmingham, Edgbaston, Birmingham, B15 2TT (United Kingdom)], E-mail: fabrizio.barone@na.infn.it

    2008-07-15

    In this paper we describe the architecture and the performances of a hybrid modular acquisition and control system prototype developed for the implementation of distributed monitoring and control systems. The system, an alternative to the VME-UDP/IP based system, is based on a dual-channel 18-bit low noise ADC and 16-bit DAC module at 800 kHz, managed by an ALTERA FPGA. Experimental tests have demonstrated that this architecture allows the implementation of distributed control systems with delay time t < 30{mu}s, on single channel, using a standard laptop PC for the real-time computation. The system was used for the longitudinal control of the end mirror of a suspended Michelson Interferometer, performed through an electrostatic actuators, giving effective performances. The preliminary results are also reported.

  19. Miniature interferometer for refractive index measurement in microfluidic chip

    Science.gov (United States)

    Chen, Minghui; Geiser, Martial; Truffer, Frederic; Song, Chengli

    2012-12-01

    The design and development of the miniaturized interferometer for measurement of the refractive index or concentration of sub-microliter volume aqueous solution in microfludic chip is presented. It is manifested by a successful measurement of the refractive index of sugar-water solution, by utilizing a laser diode for light source and the small robust instrumentation for practical implementation. Theoretically, the measurement principle and the feasibility of the system are analyzed. Experimental device is constructed with a diode laser, lens, two optical plate and a complementary metal oxide semiconductor (CMOS). Through measuring the positional changes of the interference fringes, the refractive index change are retrieved. A refractive index change of 10-4 is inferred from the measured image data. The entire system is approximately the size of half and a deck of cards and can operate on battery power for long time.

  20. Q-switched operation with Fox-Smith-Michelson laser cavity

    International Nuclear Information System (INIS)

    Huang, X; Huang, L; Gong, M

    2008-01-01

    A new kind of three-mirror composite cavity, Fox-Smith-Michelson cavity has been configured. This laser cavity is capable of high power output, owing to the low threshold of Michelson cavity. Also, thanks to the mode selection function of Fox-Smith cavity, stable pulses at high repetition rate can be generated. In our experiment, 15.54 W CW output at 1064 nm has been achieved, with an optic-to-optic conversion efficiency of 42.2%. At the Q-switching repetition rate of 100 kHz, the average output power is 11.92 W, with an optic-to-optic conversion efficiency of 38.2%. For Q-switching frequency from 30 kHz to 100 kHz, the pulse width variation is below 4.4% and the amplitude variation is below 4.8%

  1. Displacement, distance, and shape measurements of fast-rotating rough objects by two mutually tilted interference fringe systems.

    Science.gov (United States)

    Günther, Philipp; Kuschmierz, Robert; Pfister, Thorsten; Czarske, Jürgen W

    2013-05-01

    The precise distance measurement of fast-moving rough surfaces is important in several applications such as lathe monitoring. A nonincremental interferometer based on two mutually tilted interference fringe systems has been realized for this task. The distance is coded in the phase difference between the generated interference signals corresponding to the fringe systems. Large tilting angles between the interference fringe systems are necessary for a high sensitivity. However, due to the speckle effect at rough surfaces, different envelopes and phase jumps of the interference signals occur. At large tilting angles, these signals become dissimilar, resulting in a small correlation coefficient and a high measurement uncertainty. Based on a matching of illumination and receiving optics, the correlation coefficient and the phase difference estimation have been improved significantly. For axial displacement measurements of recurring rough surfaces, laterally moving with velocities of 5 m/s, an uncertainty of 110 nm has been attained. For nonrecurring surfaces, a distance measurement uncertainty of 830 nm has been achieved. Incorporating the additionally measured lateral velocity and the rotational speed, the two-dimensional shape of rotating objects results. Since the measurement uncertainty of the displacement, distance, and shape is nearly independent of the lateral surface velocity, this technique is predestined for fast-rotating objects, such as crankshafts, camshafts, vacuum pump shafts, or turning parts of lathes.

  2. Optical Ramsey spectroscopy in a rotating frame: Sagnac effect in a matter-wave interferometer

    International Nuclear Information System (INIS)

    Riehle, F.; Kisters, T.; Witte, A.; Helmcke, J.; Borde, C.J.

    1991-01-01

    A calcium atomic beam excited in an optical Ramsey geometry was rotated about an axis perpendicular to the plane defined by the laser beams and the atomic beam. A frequency shift of the Ramsey fringes of several kHz has been measured which is proportional to the rotation frequency of the apparatus and to the distance between the laser beams. The results can be interpreted in three equivalent ways as the Sagnac effect in a calcium-atomic-beam interferometer: in the rotating frame of the laser beams either along straight paths or along the curved trajectories of the atoms, or in the inertial atomic frame

  3. Circular fringe projection profilometry.

    Science.gov (United States)

    Zhao, Hong; Zhang, Chunwei; Zhou, Changquan; Jiang, Kejian; Fang, Meiqi

    2016-11-01

    In this Letter, a novel three-dimensional (3D) measurement method, called the circular fringe projection profilometry (CFPP), is proposed. Similar to the conventional fringe projection profilometry, CFPP also requires fringe pattern projection and capture, phase demodulation, and phase unwrapping. However, it works with a totally different mechanism. CFPP recovers the height of a point by calculating its distance to the optical center of a projector along the optical axis. This distance is calculated with the aid of the divergence angle of a projected light ray and the distance between the measured point and the optical axis. The distance between the measured point and the optical axis is detected by a camera with telecentric lenses, while the divergence angle can be calculated from the phase of a captured circular fringe pattern. The validity of CFPP is confirmed by a set of experiments.

  4. Control bandwidth improvements in GRAVITY fringe tracker by switching to a synchronous real time computer architecture

    Science.gov (United States)

    Abuter, Roberto; Dembet, Roderick; Lacour, Sylvestre; di Lieto, Nicola; Woillez, Julien; Eisenhauer, Frank; Fedou, Pierre; Phan Duc, Than

    2016-08-01

    The new VLTI (Very Large Telescope Interferometer) 1 instrument GRAVITY5, 22, 23 is equipped with a fringe tracker16 able to stabilize the K-band fringes on six baselines at the same time. It has been designed to achieve a performance for average seeing conditions of a residual OPD (Optical Path Difference) lower than 300 nm with objects brighter than K = 10. The control loop implementing the tracking is composed of a four stage real time computer system compromising: a sensor where the detector pixels are read in and the OPD and GD (Group Delay) are calculated; a controller receiving the computed sensor quantities and producing commands for the piezo actuators; a concentrator which combines both the OPD commands with the real time tip/tilt corrections offloading them to the piezo actuator; and finally a Kalman15 parameter estimator. This last stage is used to monitor current measurements over a window of few seconds and estimate new values for the main Kalman15 control loop parameters. The hardware and software implementation of this design runs asynchronously and communicates the four computers for data transfer via the Reflective Memory Network3. With the purpose of improving the performance of the GRAVITY5, 23 fringe tracking16, 22 control loop, a deviation from the standard asynchronous communication mechanism has been proposed and implemented. This new scheme operates the four independent real time computers involved in the tracking loop synchronously using the Reflective Memory Interrupts2 as the coordination signal. This synchronous mechanism had the effect of reducing the total pure delay of the loop from 3.5 [ms] to 2.0 [ms] which then translates on a better stabilization of the fringes as the bandwidth of the system is substantially improved. This paper will explain in detail the real time architecture of the fringe tracker in both is synchronous and synchronous implementation. The achieved improvements on reducing the delay via this mechanism will be

  5. 48 CFR 731.372 - Fringe benefits.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Fringe benefits. 731.372 Section 731.372 Federal Acquisition Regulations System AGENCY FOR INTERNATIONAL DEVELOPMENT GENERAL....372 Fringe benefits. USAID's policies on certain fringe benefits related to overseas service...

  6. The Fourier-Kelvin Stellar Interferometer (FKSI) Nulling Testbed II: Closed-loop Path Length Metrology And Control Subsystem

    Science.gov (United States)

    Frey, B. J.; Barry, R. K.; Danchi, W. C.; Hyde, T. T.; Lee, K. Y.; Martino, A. J.; Zuray, M. S.

    2006-01-01

    The Fourier-Kelvin Stellar Interferometer (FKSI) is a mission concept for an imaging and nulling interferometer in the near to mid-infrared spectral region (3-8 microns), and will be a scientific and technological pathfinder for upcoming missions including TPF-I/DARWIN, SPECS, and SPIRIT. At NASA's Goddard Space Flight Center, we have constructed a symmetric Mach-Zehnder nulling testbed to demonstrate techniques and algorithms that can be used to establish and maintain the 10(exp 4) null depth that will be required for such a mission. Among the challenges inherent in such a system is the ability to acquire and track the null fringe to the desired depth for timescales on the order of hours in a laboratory environment. In addition, it is desirable to achieve this stability without using conventional dithering techniques. We describe recent testbed metrology and control system developments necessary to achieve these goals and present our preliminary results.

  7. Computer-assisted techniques to evaluate fringe patterns

    Science.gov (United States)

    Sciammarella, Cesar A.; Bhat, Gopalakrishna K.

    1992-01-01

    Strain measurement using interferometry requires an efficient way to extract the desired information from interferometric fringes. Availability of digital image processing systems makes it possible to use digital techniques for the analysis of fringes. In the past, there have been several developments in the area of one dimensional and two dimensional fringe analysis techniques, including the carrier fringe method (spatial heterodyning) and the phase stepping (quasi-heterodyning) technique. This paper presents some new developments in the area of two dimensional fringe analysis, including a phase stepping technique supplemented by the carrier fringe method and a two dimensional Fourier transform method to obtain the strain directly from the discontinuous phase contour map.

  8. 41 CFR 101-4.525 - Fringe benefits.

    Science.gov (United States)

    2010-07-01

    ... 41 Public Contracts and Property Management 2 2010-07-01 2010-07-01 true Fringe benefits. 101-4... in Employment in Education Programs or Activities Prohibited § 101-4.525 Fringe benefits. (a) “Fringe benefits” defined. For purposes of these Title IX regulations, fringe benefits means: Any medical, hospital...

  9. Fringe image analysis based on the amplitude modulation method.

    Science.gov (United States)

    Gai, Shaoyan; Da, Feipeng

    2010-05-10

    A novel phase-analysis method is proposed. To get the fringe order of a fringe image, the amplitude-modulation fringe pattern is carried out, which is combined with the phase-shift method. The primary phase value is obtained by a phase-shift algorithm, and the fringe-order information is encoded in the amplitude-modulation fringe pattern. Different from other methods, the amplitude-modulation fringe identifies the fringe order by the amplitude of the fringe pattern. In an amplitude-modulation fringe pattern, each fringe has its own amplitude; thus, the order information is integrated in one fringe pattern, and the absolute fringe phase can be calculated correctly and quickly with the amplitude-modulation fringe image. The detailed algorithm is given, and the error analysis of this method is also discussed. Experimental results are presented by a full-field shape measurement system where the data has been processed using the proposed algorithm. (c) 2010 Optical Society of America.

  10. Fringes in FTIR spectroscopy revisited: understanding and modelling fringes in infrared spectroscopy of thin films.

    Science.gov (United States)

    Konevskikh, Tatiana; Ponossov, Arkadi; Blümel, Reinhold; Lukacs, Rozalia; Kohler, Achim

    2015-06-21

    The appearance of fringes in the infrared spectroscopy of thin films seriously hinders the interpretation of chemical bands because fringes change the relative peak heights of chemical spectral bands. Thus, for the correct interpretation of chemical absorption bands, physical properties need to be separated from chemical characteristics. In the paper at hand we revisit the theory of the scattering of infrared radiation at thin absorbing films. Although, in general, scattering and absorption are connected by a complex refractive index, we show that for the scattering of infrared radiation at thin biological films, fringes and chemical absorbance can in good approximation be treated as additive. We further introduce a model-based pre-processing technique for separating fringes from chemical absorbance by extended multiplicative signal correction (EMSC). The technique is validated by simulated and experimental FTIR spectra. It is further shown that EMSC, as opposed to other suggested filtering methods for the removal of fringes, does not remove information related to chemical absorption.

  11. Fringe order error in multifrequency fringe projection phase unwrapping: reason and correction.

    Science.gov (United States)

    Zhang, Chunwei; Zhao, Hong; Zhang, Lu

    2015-11-10

    A multifrequency fringe projection phase unwrapping algorithm (MFPPUA) is important to fringe projection profilometry, especially when a discontinuous object is measured. However, a fringe order error (FOE) may occur when MFPPUA is adopted. An FOE will result in error to the unwrapped phase. Although this kind of phase error does not spread, it brings error to the eventual 3D measurement results. Therefore, an FOE or its adverse influence should be obviated. In this paper, reasons for the occurrence of an FOE are theoretically analyzed and experimentally explored. Methods to correct the phase error caused by an FOE are proposed. Experimental results demonstrate that the proposed methods are valid in eliminating the adverse influence of an FOE.

  12. 18 CFR 1317.525 - Fringe benefits.

    Science.gov (United States)

    2010-04-01

    ... 18 Conservation of Power and Water Resources 2 2010-04-01 2010-04-01 false Fringe benefits. 1317... benefits. (a) “Fringe benefits” defined. For purposes of these Title IX regulations, fringe benefits means: Any medical, hospital, accident, life insurance, or retirement benefit, service, policy or plan, any...

  13. 13 CFR 113.525 - Fringe benefits.

    Science.gov (United States)

    2010-01-01

    ... 13 Business Credit and Assistance 1 2010-01-01 2010-01-01 false Fringe benefits. 113.525 Section... benefits. (a) “Fringe benefits” defined. For purposes of these Title IX regulations, fringe benefits means: Any medical, hospital, accident, life insurance, or retirement benefit, service, policy or plan, any...

  14. 38 CFR 23.525 - Fringe benefits.

    Science.gov (United States)

    2010-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 2 2010-07-01 2010-07-01 false Fringe benefits. 23.525... benefits. (a) “Fringe benefits” defined. For purposes of these Title IX regulations, fringe benefits means: Any medical, hospital, accident, life insurance, or retirement benefit, service, policy or plan, any...

  15. 45 CFR 2555.525 - Fringe benefits.

    Science.gov (United States)

    2010-10-01

    ... 45 Public Welfare 4 2010-10-01 2010-10-01 false Fringe benefits. 2555.525 Section 2555.525 Public... benefits. (a) “Fringe benefits” defined. For purposes of these Title IX regulations, fringe benefits means: Any medical, hospital, accident, life insurance, or retirement benefit, service, policy or plan, any...

  16. 34 CFR 106.56 - Fringe benefits.

    Science.gov (United States)

    2010-07-01

    ... 34 Education 1 2010-07-01 2010-07-01 false Fringe benefits. 106.56 Section 106.56 Education... benefits. (a) Fringe benefits defined. For purposes of this part, fringe benefits means: Any medical, hospital, accident, life insurance or retirement benefit, service, policy or plan, any profit-sharing or...

  17. 45 CFR 618.525 - Fringe benefits.

    Science.gov (United States)

    2010-10-01

    ... 45 Public Welfare 3 2010-10-01 2010-10-01 false Fringe benefits. 618.525 Section 618.525 Public... benefits. (a) “Fringe benefits” defined. For purposes of these Title IX regulations, fringe benefits means: Any medical, hospital, accident, life insurance, or retirement benefit, service, policy or plan, any...

  18. 24 CFR 3.525 - Fringe benefits.

    Science.gov (United States)

    2010-04-01

    ... 24 Housing and Urban Development 1 2010-04-01 2010-04-01 false Fringe benefits. 3.525 Section 3... benefits. (a) “Fringe benefits” defined. For purposes of these Title IX regulations, fringe benefits means: Any medical, hospital, accident, life insurance, or retirement benefit, service, policy or plan, any...

  19. Making sense of nanocrystal lattice fringes

    International Nuclear Information System (INIS)

    Fraundorf, P.; Qin Wentao; Moeck, Peter; Mandell, Eric

    2005-01-01

    The orientation dependence of thin-crystal lattice fringes can be gracefully quantified using fringe-visibility maps, a direct-space analog of Kikuchi maps [Nishikawa and Kikuchi, Nature (London) 121, 1019 (1928)]. As in navigation of reciprocal space with the aid of Kikuchi lines, fringe-visibility maps facilitate acquisition of crystallographic information from lattice images. In particular, these maps can help researchers to determine the three-dimensional lattice of individual nanocrystals, to 'fringe-fingerprint' collections of randomly oriented particles, and to measure local specimen thickness with only a modest tilt. Since the number of fringes in an image increases with maximum spatial-frequency squared, these strategies (with help from more precise goniometers) will be more useful as aberration correction moves resolutions into the subangstrom range

  20. Fringe Benefits of Interferometry

    Indian Academy of Sciences (India)

    It was Michelson whocarried out this programme and made the first direct measurementof the giant star Betelguse in the constellation ofOrion. His value for the angular diameter, 47 milliarcsecondsor 2.6×10−7 radians, was completely confirmed by laterwork following his methods. The key concept introduced was.

  1. Interferometer for electron density measurement in exploding wire plasma

    International Nuclear Information System (INIS)

    Batra, Jigyasa; Jaiswar, Ashutosh; Kaushik, T.C.

    2016-12-01

    Mach-Zehnder Interferometer (MZI) has been developed for measuring electron density profile in pulsed plasmas. MZI is to be used for characterizing exploding wire plasmas for correlating electron density dynamics with x-rays emission. Experiments have been carried out for probing electron density in pulsed plasmas produced in our laboratory like in spark gap and exploding wire plasmas. These are microsecond phenomenon. Changes in electron density have been registered in interferograms with the help of a streak camera for specific time window. Temporal electron density profiles have been calculated by analyzing temporal fringe shifts in interferograms. This report deals with details of MZI developed in our laboratory along with its theory. Basic introductory details have also been provided for exploding wire plasmas to be probed. Some demonstrative results of electron density measurements in pulsed plasmas of spark gap and single exploding wires have been described. (author)

  2. Detection of Human Ig G Using Photoluminescent Porous Silicon Interferometer.

    Science.gov (United States)

    Cho, Bomin; Kim, Seongwoong; Woo, Hee-Gweon; Kim, Sungsoo; Sohn, Honglae

    2015-02-01

    Photoluminescent porous silicon (PSi) interferometers having dual optical properties, both Fabry-Pérot fringe and photolumincence (PL), have been developed and used as biosensors for detection of Human Immunoglobin G (Ig G). PSi samples were prepared by electrochemical etching of p-type silicon under white light exposure. The surface of PSi was characterized using a cold field emission scanning electron microscope. The sensor system studied consisted of a single layer of porous silicon modified with Protein A. The system was probed with various fragments of aqueous human immunoglobin G (Ig G) analyte. Both reflectivity and PL were simultaneously measured under the exposure of human Ig G. An increase of optical thickness and decrease of PL were obtained under the exposure of human Ig G. Detection limit of 500 fM was observed for the human Ig G.

  3. Quality-guided orientation unwrapping for fringe direction estimation.

    Science.gov (United States)

    Wang, Haixia; Kemao, Qian

    2012-02-01

    Fringe patterns produced by various optical interferometric techniques encode information such as shape, deformation, and refractive index. Denoising and demodulation are two important procedures to retrieve information from a single closed fringe pattern. Various existing denoising and demodulation techniques require fringe direction/orientation during the processing. Fringe orientation is often easier to obtain but fringe direction is needed in some demodulation techniques. A quality-guided orientation unwrapping scheme is proposed to estimate direction from orientation. Two techniques, one based on windowed Fourier ridges and the other based on fringe gradient, are proposed for the quality-guided orientation unwrapping scheme. The direction qualities are compared for both simulated and experimental fringe patterns. Their application to demodulation technique is also given.

  4. Fringing-field effects in acceleration columns

    International Nuclear Information System (INIS)

    Yavor, M.I.; Weick, H.; Wollnik, H.

    1999-01-01

    Fringing-field effects in acceleration columns are investigated, based on the fringing-field integral method. Transfer matrices at the effective boundaries of the acceleration column are obtained, as well as the general transfer matrix of the region separating two homogeneous electrostatic fields with different field strengths. The accuracy of the fringing-field integral method is investigated

  5. Wills plasma physics department twenty-eighth 6-monthly progress report 1st July-31st December 1974

    International Nuclear Information System (INIS)

    1975-01-01

    Progress is reported on several research programs which include: 1) plasma sources, 2) hydromagnetic shock waves, 3) rotating plasmas, 4) icr heating and magnetoacoustic heating, 5) carbon dioxide laser interferometer, 6) dye lasers, and 7) plasmascanned Michelson interferometer. (R.L.)

  6. The design and evaluation of a selectively modulated interferometric dispersive spectrometer

    International Nuclear Information System (INIS)

    Fitzgerald, J.J.

    1986-01-01

    In approaching the problem of rapid simultaneous multielement analysis, the large light gathering power, wide spectral range and high resolution of a Fourier Transform Spectrometer (FTS) should be of benefit. The severe mechanical tolerances required in the construction and operation of a classical Michelson interferometer for use in the UV-Visible spectral region have limited investigations in the application of simultaneous trace quantitative analysis. Theory is presented demonstrating that replacement of the fixed mirror in one arm of the Michelson interferometer with a rotating grating preserves most of the FTS advantages and results in a greatly simplified detector system. No mathematical Fourier transform is required. The need for a computer is eliminated. An instrument, SEMIDS (Selectively Modulated Interferometric Dispersive Spectrometer), was constructed to investigate the mathematical model. Design criteria and basic operational performance as a flame emission spectrometer are presented. SEMIDS achieved high resolution, high throughput and greatly simplified operation compared to a Michelson interferometer. Performance as a trace quantitative tool was disappoint because of unanticipated noise contributions from flame background. A summary of the noise component contributions is discussed

  7. Onboard calibration and monitoring for the SWIFT instrument

    International Nuclear Information System (INIS)

    Rahnama, P; McDade, I; Shepherd, G; Gault, W

    2012-01-01

    The SWIFT (Stratospheric Wind Interferometer for Transport studies) instrument is a proposed space-based field-widened Doppler Michelson interferometer designed to measure stratospheric winds and ozone densities using a passive optical technique called Doppler Michelson imaging interferometry. The onboard calibration and monitoring procedures for the SWIFT instrument are described in this paper. Sample results of the simulations of onboard calibration measurements are presented and discussed. This paper also discusses the results of the derivation of the calibrations and monitoring requirements for the SWIFT instrument. SWIFT's measurement technique and viewing geometry are briefly described. The reference phase calibration and filter monitoring for the SWIFT instrument are two of the main critical design issues. In this paper it is shown that in order to meet SWIFT's science requirements, Michelson interferometer optical path difference monitoring corresponding to a phase calibration accuracy of ∼10 −3 radians, filter passband monitoring corresponding to phase accuracy of ∼5 × 10 −3 radians and a thermal stability of 10 −3 K s −1 are required. (paper)

  8. Temperature-independent refractometer based on fiber-optic Fabry-Perot interferometer

    Science.gov (United States)

    Li, Jiacheng; Qiao, Xueguang; Wang, Ruohui; Rong, Qiangzhou; Bao, Weijia; Shao, Zhihua; Yang, Tingting

    2016-04-01

    A miniature fiber-optic refractometer based on Fabry-Perot interferometer (FPI) has been proposed and experimentally demonstrated. The sensing head consists of a short section of photonics crystal fiber (PCF) spliced to a single mode fiber (SMF), in which the end-face of the PCF is etched to remove holey structure with hydrofluoric (HF) acid. A Fabry-Perot interference spectrum is achieved based on the reflections from the fusion splicing interface and the end-face of the core of PCF. The interference fringe is sensitive to the external refractive index (RI) with an intensity-referenced sensitivity of 358.27 dB/RIU ranging from 1.33 to 1.38. The sensor has also been implemented for the concentration measurement of λ-phage DNA solution. In addition, the dip intensity is insensitive to the ambient temperature variation, making it a good candidate for temperature-independent bio-sensing area.

  9. Special relativity and interferometers

    Science.gov (United States)

    Han, D.; Kim, Y. S.

    1988-01-01

    A new generation of gravitational wave detectors is expected to be based on interferometers. Yurke et al. (1986) introduced a class of interferometers characterized by SU(1,1) which can in principle achieve a phase sensitivity approaching 1/N, where N is thte total number of photons entering the interferometer. It is shown here that the SU(1,1) interferometer can serve as an analog computer for Wigner's little group of the Poincare\\'| group.

  10. Wages or Fringes?

    DEFF Research Database (Denmark)

    Eriksson, Tor Viking; Kristensen, Nicolai

    The two key predictions of hedonic wage theory are that there is a trade-o¤ between wages and nonmonetary rewards and that the latter can be used as a sorting device by firms to attract and retain the kind of employees they desire. Empirical analysis of these topics are scarce as they require...... negative wage-fringe trade-offs, con-siderable heterogeneity in willingness to pay for fringe benefits, and signs of sorting. The findings imply that personnel economics models can be applied also to the analysis of nonmonetary rewards....

  11. Overall comparison of subpicosecond electron beam diagnostics by the polychromator, the interferometer and the femtosecond streak camera

    CERN Document Server

    Watanabe, T; Yoshimatsu, T; Sasaki, S; Sugiyama, Y; Ishi, K; Shibata, Y; Kondo, Y; Yoshii, K; Ueda, T; Uesaka, M

    2002-01-01

    Measurements of longitudinal bunch length of subpicosecond and picosecond electron beams have been performed by three methods with three radiation sources at the 35 MeV S-band twin liner accelerators at Nuclear Engineering Research Laboratory, University of Tokyo. The methods we adopt are the femtosecond streak camera with a nondispersive reflective optics, the coherent transition radiation (CTR) Michelson interferometer and the 10 ch polychromator that detects the spectrum of CTR and coherent diffraction radiation (CDR). The measurements by the two CTR methods were independently done with the streak camera and their results were consistent with one another. As a result, the reliability of the polychromator for the diagnostics of less than picosecond electron bunch and the usefulness of the diagnostics for the single shot measurement were verified. Furthermore, perfect nondestructive diagnostics for subpicosecond bunches was performed utilizing CDR interferometry. Then the good agreement between CDR interfero...

  12. Effects of diotic fringes on interaural disparity detection (L)

    DEFF Research Database (Denmark)

    Le Goff, Nicolas; Kohlrausch, Armin; Dau, Torsten

    2012-01-01

    Detection thresholds were measured for interaural time differences (ITDs) and interaural level differences (ILDs) that were carried by probe segments embedded in otherwise diotic broadband noise (fringe). The duration of the probe was varied between 5 and 200 ms, and the duration of the fringe...... was between 5 and 100 ms. Consistent with results of Akeroyd and Bernstein [(2001). J. Acoust. Soc. Am. 110, 2516-2526], it was found that a 5-ms fringe placed before a 5-ms probe (forward fringe) led to a larger threshold elevation than a 5-ms fringe placed after the probe (backward fringe). As suggested...... by Akeroyd and Bernstein, this effect was accounted for by a model providing an onset emphasis of a factor of 2. In contrast, for longer probe and fringe durations, which have not been tested before, a backward fringe had a stronger effect than a forward fringe. This surprising effect was accounted...

  13. 29 CFR 4.52 - Fringe benefit determinations.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 1 2010-07-01 2010-07-01 true Fringe benefit determinations. 4.52 Section 4.52 Labor... Procedures § 4.52 Fringe benefit determinations. (a) Wage determinations issued pursuant to the Service... differential, which are considered wages rather than fringe benefits under SCA). Pursuant to Section 4(b) of...

  14. Refractive index and temperature-sensing characteristics of a cladding-etched thin core fiber interferometer

    Science.gov (United States)

    Wang, Weiying; Dong, Xinran; Chu, Dongkai; Hu, Youwang; Sun, Xiaoyan; Duan, Ji-An

    2018-05-01

    A high refractive index (RI) sensor based on an in-line Mach-Zehnder mode interferometer (MZI) is proposed. The sensor was realized by splicing a 2-cm length of cladding-etched thin core fiber (TCF) between two single mode fibers (SMFs). The TCF-structured MZI exhibited good fringe visibility as high as 15 dB in air and the high RI sensitivity attained a value of 1143.89 nm/RIU at a RI of 1.447. The experimental data revealed that the MZI has high RI sensitivity after HF etching realizing 2599.66 nm/RIU. Studies were performed on the temperature characteristics of the device. It is anticipated that this high RI sensor will be deployed in new and diverse applications in the chemical and biological fields.

  15. 7 CFR 15a.56 - Fringe benefits.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 1 2010-01-01 2010-01-01 false Fringe benefits. 15a.56 Section 15a.56 Agriculture Office of the Secretary of Agriculture EDUCATION PROGRAMS OR ACTIVITIES RECEIVING OR BENEFITTING FROM... Activities Prohibited § 15a.56 Fringe benefits. (a) “Fringe benefits” defined. For purposes of this part...

  16. The complex and quaternionic quantum bit from relativity of simultaneity on an interferometer.

    Science.gov (United States)

    Garner, Andrew J P; Müller, Markus P; Dahlsten, Oscar C O

    2017-12-01

    The patterns of fringes produced by an interferometer have long been important testbeds for our best contemporary theories of physics. Historically, interference has been used to contrast quantum mechanics with classical physics, but recently experiments have been performed that test quantum theory against even more exotic alternatives. A physically motivated family of theories are those where the state space of a two-level system is given by a sphere of arbitrary dimension. This includes classical bits, and real, complex and quaternionic quantum theory. In this paper, we consider relativity of simultaneity (i.e. that observers may disagree about the order of events at different locations) as applied to a two-armed interferometer, and show that this forbids most interference phenomena more complicated than those of complex quantum theory. If interference must depend on some relational property of the setting (such as path difference), then relativity of simultaneity will limit state spaces to standard complex quantum theory, or a subspace thereof. If this relational assumption is relaxed, we find one additional theory compatible with relativity of simultaneity: quaternionic quantum theory. Our results have consequences for current laboratory interference experiments: they have to be designed carefully to avoid rendering beyond-quantum effects invisible by relativity of simultaneity.

  17. Development of a signal-extraction scheme for resonant sideband extraction

    International Nuclear Information System (INIS)

    Kokeyama, K; Kawazoe, F; Sugamoto, A; Somiya, K; Sato, S; Kawamura, S

    2008-01-01

    As a future plan, an advanced gravitational-wave detector will employ an optical configuration of resonant sideband extraction (RSE), achieved with an additional mirror at the signal-detection port of the power-recycled Fabry-Perot Michelson interferometer. To control the complex coupled cavity system, one of the most important design issues is how to extract the longitudinal control signals of the cavities. We have developed a new signal-extraction scheme which provides an appropriate sensing matrix. The new method uses two sets of sidebands: one of the sideband components satisfies the critical coupling condition for the RSE interferometer and reaches the signal-extraction port, and the other sideband is completely reflected by the Michelson interferometer. They provide a diagonalized sensing matrix and enable the RSE control to be robust

  18. Comparative Sensitivities of Gravitational Wave Detectors Based on Atom Interferometers and Light Interferometers

    Science.gov (United States)

    Baker, John G.; Thorpe, J. I.

    2012-01-01

    We consider a class of proposed gravitational wave detectors based on multiple atomic interferometers separated by large baselines and referenced by common laser systems. We compute the sensitivity limits of these detectors due to intrinsic phase noise of the light sources, non-inertial motion of the light sources, and atomic shot noise and compare them to sensitivity limits for traditional light interferometers. We find that atom interferometers and light interferometers are limited in a nearly identical way by intrinsic phase noise and that both require similar mitigation strategies (e.g. multiple arm instruments) to reach interesting sensitivities. The sensitivity limit from motion of the light sources is slightly different and favors the atom interferometers in the low-frequency limit, although the limit in both cases is severe. Whether this potential advantage outweighs the additional complexity associated with including atom interferometers will require further study.

  19. 15 CFR 8a.525 - Fringe benefits.

    Science.gov (United States)

    2010-01-01

    ... 15 Commerce and Foreign Trade 1 2010-01-01 2010-01-01 false Fringe benefits. 8a.525 Section 8a.525 Commerce and Foreign Trade Office of the Secretary of Commerce NONDISCRIMINATION ON THE BASIS OF SEX IN... in Employment in Education Programs or Activities Prohibited § 8a.525 Fringe benefits. (a) “Fringe...

  20. Digital signal processing for velocity measurements in dynamical material's behaviour studies

    International Nuclear Information System (INIS)

    Devlaminck, Julien; Luc, Jerome; Chanal, Pierre-Yves

    2014-01-01

    In this work, we describe different configurations of optical fiber interferometers (types Michelson and Mach-Zehnder) used to measure velocities during dynamical material's behaviour studies. We detail the algorithms of processing developed and optimized to improve the performance of these interferometers especially in terms of time and frequency resolutions. Three methods of analysis of interferometric signals were studied. For Michelson interferometers, the time-frequency analysis of signals by Short-Time Fourier Transform (STFT) is compared to a time-frequency analysis by Continuous Wavelet Transform (CWT). The results have shown that the CWT was more suitable than the STFT for signals with low signal-to-noise, and low velocity and high acceleration areas. For Mach- Zehnder interferometers, the measurement is carried out by analyzing the phase shift between three interferometric signals (Triature processing). These three methods of digital signal processing were evaluated, their measurement uncertainties estimated, and their restrictions or operational limitations specified from experimental results performed on a pulsed power machine. (authors)

  1. Fringing in MonoCam Y4 filter images

    International Nuclear Information System (INIS)

    Brooks, J.; Nomerotski, A.; Fisher-Levine, M.

    2017-01-01

    We study the fringing patterns observed in MonoCam, a camera with a single Large Synoptic Survey Telescope (LSST) CCD sensor. Images were taken at the U.S. Naval Observatory in Flagstaff, Arizona (NOFS) employing its 1.3 m telescope and an LSST y 4 filter. Fringing occurs due to the reflection of infrared light (700 nm or larger) from the bottom surface of the CCD which constructively or destructively interferes with the incident light to produce a net ''fringe'' pattern which is superimposed on all images taken. Emission lines from the atmosphere, dominated by hydroxyl (OH) spectra, can change in their relative intensities as the night goes on, producing different fringe patterns in the images taken. We found through several methods that the general shape of the fringe patterns remained constant, though with slight changes in the amplitude and phase of the fringes. We also found that a superposition of fringes from two monochromatic lines taken in the lab offered a reasonable description of the sky data.

  2. Comparison of Atom Interferometers and Light Interferometers as Space-Based Gravitational Wave Detectors

    Science.gov (United States)

    Baker, John G.

    2012-01-01

    We consider a class of proposed gravitational wave detectors based on multiple atomic interferometers separated by large baselines and referenced by common laser systems. We compute the sensitivity limits of these detectors due to intrinsic phase noise of the light sources, non-inertial motion of the light sources, and atomic shot noise and compare them to sensitivity limits for traditional light interferometers. We find that atom interferometers and light interferometers are limited in a nearly identical way by intrinsic phase noise and that both require similar mitigation strategies (e.g. multiple arm instruments) to reach interesting sensitivities. The sensitivity limit from motion of the light sources is slightly different and favors the atom interferometers in the low-frequency limit, although the limit in both cases is severe.

  3. Remote access to an interferometric fringes stabilization active system via RENATA

    Science.gov (United States)

    Espitia-Gómez, Javier; Ángel-Toro, Luciano

    2013-11-01

    The Advanced Technology National Network (RENATA, for its acronym in Spanish) is a Colombian, collaborative work tool, linked to other networks worldwide, in which take participation researchers, teachers and students, by sharing laboratory resources located in different universities, institutes and research centers throughout the country. In the Universidad EAFIT (Medellín, Colombia) it has been designed an interferometric fringes stabilization active system, which can be accessed remotely via the RENATA network. A Mach-Zehnder interferometer was implemented, with independent piezoelectric actuators in each arm, with which the lengths of optical path of light that goes over in each of them can be modified. Using these actuators, one can simultaneously perturb the system and compensate the phase differences caused by that perturbation. This allows us to experiment with different disturbs, and analyze the system response to each one of them. This can be made from any location worldwide, and especially from those regions in which optical and optoelectronic components required for the implementation of the interferometer or for the stabilization system are not available. The device can also be used as a platform in order to conduct diverse experiments, involving optical and controlling aspects, constituting with this in a pedagogic tool. For the future, it can be predicted that remote access to available applications would be possible, as well as modifications of the implemented code in labVIEW™, so that researchers and teachers can adapt and improve their functionalities or develop new applications, based on the collaborative work.

  4. Windowed fringe pattern analyis

    CERN Document Server

    Kemao, Qian

    2013-01-01

    This book provides solutions to the challenges involved in fringe pattern analysis, covering techniques for full-field, noncontact, and high-sensitivity measurement. The primary goal of fringe pattern analysis is to extract the hidden phase distributions that generally relate to the physical quantities being measured. Both theoretical analysis and algorithm development are covered to facilitate the work of researchers and engineers. The information presented is also appropriate as a specialized subject for students of optical and computer engineering.

  5. Robust Fringe Projection Profilometry via Sparse Representation.

    Science.gov (United States)

    Budianto; Lun, Daniel P K

    2016-04-01

    In this paper, a robust fringe projection profilometry (FPP) algorithm using the sparse dictionary learning and sparse coding techniques is proposed. When reconstructing the 3D model of objects, traditional FPP systems often fail to perform if the captured fringe images have a complex scene, such as having multiple and occluded objects. It introduces great difficulty to the phase unwrapping process of an FPP system that can result in serious distortion in the final reconstructed 3D model. For the proposed algorithm, it encodes the period order information, which is essential to phase unwrapping, into some texture patterns and embeds them to the projected fringe patterns. When the encoded fringe image is captured, a modified morphological component analysis and a sparse classification procedure are performed to decode and identify the embedded period order information. It is then used to assist the phase unwrapping process to deal with the different artifacts in the fringe images. Experimental results show that the proposed algorithm can significantly improve the robustness of an FPP system. It performs equally well no matter the fringe images have a simple or complex scene, or are affected due to the ambient lighting of the working environment.

  6. LineVISAR. A fringe-trace data analysis program

    Energy Technology Data Exchange (ETDEWEB)

    Furnish, Michael D. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2014-02-01

    The line-imaging ORVIS or VISAR provides velocity as a function of position and time for a line on an experimental setup via a streak camera record of interference fringes. This document describes a Matlab-based program which guides the user through the process of converting these fringe data to a velocity surface. The data reduction is of the "fringe trace" type, wherein the changes in velocity at a given position on the line are calculated based on fringe motion past that point. The analyst must establish the fringe behavior up front, aided by peak-finding routines in the program. However, the later work of using fringe jumps to compensate for phase problems in other analysis techniques is greatly reduced. This program is not a standard GUI construction, and is prescriptive. At various points it saves the progress, allowing later restarts from those points.

  7. Contribution to the theory of atom interferometers

    International Nuclear Information System (INIS)

    Antoine, Ch.

    2004-12-01

    This work deals with the study of atom interferometers. It consists of theoretical developments and more practical parts (modeling). As regards modeling, this work explains how to obtain a general analytical expression of the fringes signal, which particularly accounts for the simultaneous action of all the inertial and gravitational fields whose representative potential is at most quadratic in position and momentum (rotations, accelerations, gradients of acceleration, gravitational waves...), as well as the dispersive structuring due to atomic beam splitters in the presence of such external fields (velocity selection, anomalous dispersion and Borrmann effect). From a theoretical point of view, this thesis develops new tools of atom optics. They deal with the propagation of matter waves in unspecified inertial and gravitational fields (extension of the ABCD formalism using first integral operators), the study of laser beam splitters in the presence of some of these fields (generalized ttt scheme, strong fields ttt modeling, generalized Borrmann effect...), as well as the highlight of symplectic invariants which are very useful for the interpretation and the simplification of the phase shift expression ('homologous paths' and 'four end points theorem'). (author)

  8. A procedure for noise uncoupling in laser interferometry

    CERN Document Server

    Barone, F; Rosa, R D; Eleuteri, A; Milano, L; Qipiani, K

    2002-01-01

    A numerical procedure for noise recognition and uncoupling is described. The procedure is applied to a Michelson interferometer and is effective in seismic and acoustic noise uncoupling from the output signal of the interferometer. Due to the low data flow coming from the instrumentation this uncoupling can be performed in real time and it is useful as a data quality procedure for interferometer data output.

  9. The energy-time uncertainty principle and the EPR paradox: Experiments involving correlated two-photon emission in parametric down-conversion

    Science.gov (United States)

    Chiao, Raymond Y.; Kwiat, Paul G.; Steinberg, Aephraim M.

    1992-01-01

    The energy-time uncertainty principle is on a different footing than the momentum position uncertainty principle: in contrast to position, time is a c-number parameter, and not an operator. As Aharonov and Bohm have pointed out, this leads to different interpretations of the two uncertainty principles. In particular, one must distinguish between an inner and an outer time in the definition of the spread in time, delta t. It is the inner time which enters the energy-time uncertainty principle. We have checked this by means of a correlated two-photon light source in which the individual energies of the two photons are broad in spectra, but in which their sum is sharp. In other words, the pair of photons is in an entangled state of energy. By passing one member of the photon pair through a filter with width delta E, it is observed that the other member's wave packet collapses upon coincidence detection to a duration delta t, such that delta E(delta t) is approximately equal to planks constant/2 pi, where this duration delta t is an inner time, in the sense of Aharonov and Bohm. We have measured delta t by means of a Michelson interferometer by monitoring the visibility of the fringes seen in coincidence detection. This is a nonlocal effect, in the sense that the two photons are far away from each other when the collapse occurs. We have excluded classical-wave explanations of this effect by means of triple coincidence measurements in conjunction with a beam splitter which follows the Michelson interferometer. Since Bell's inequalities are known to be violated, we believe that it is also incorrect to interpret this experimental outcome as if energy were a local hidden variable, i.e., as if each photon, viewed as a particle, possessed some definite but unknown energy before its detection.

  10. INTERFERENCE FRINGES OF SOLAR ACOUSTIC WAVES AROUND SUNSPOTS

    Energy Technology Data Exchange (ETDEWEB)

    Chou, Dean-Yi; Zhao Hui; Yang, Ming-Hsu; Liang, Zhi-Chao, E-mail: chou@phys.nthu.edu.tw [Physics Department, National Tsing Hua University, Hsinchu, Taiwan (China)

    2012-10-20

    Solar acoustic waves are scattered by a sunspot due to the interaction between the acoustic waves and the sunspot. The sunspot, excited by the incident wave, generates the scattered wave. The scattered wave is added to the incident wave to form the total wave around the sunspot. The interference fringes between the scattered wave and the incident wave are visible in the intensity of the total wave because the coherent time of the incident wave is of the order of a wave period. The strength of the interference fringes anti-correlates with the width of temporal spectra of the incident wave. The separation between neighboring fringes increases with the incident wavelength and the sunspot size. The strength of the fringes increases with the radial order n of the incident wave from n = 0 to n = 2, and then decreases from n = 2 to n = 5. The interference fringes play a role analogous to holograms in optics. This study suggests the feasibility of using the interference fringes to reconstruct the scattered wavefields of the sunspot, although the quality of the reconstructed wavefields is sensitive to the noise and errors in the interference fringes.

  11. Simultaneous Water Vapor and Dry Air Optical Path Length Measurements and Compensation with the Large Binocular Telescope Interferometer

    Science.gov (United States)

    Defrere, D.; Hinz, P.; Downey, E.; Boehm, M.; Danchi, W. C.; Durney, O.; Ertel, S.; Hill, J. M.; Hoffmann, W. F.; Mennesson, B.; hide

    2016-01-01

    The Large Binocular Telescope Interferometer uses a near-infrared camera to measure the optical path length variations between the two AO-corrected apertures and provide high-angular resolution observations for all its science channels (1.5-13 microns). There is however a wavelength dependent component to the atmospheric turbulence, which can introduce optical path length errors when observing at a wavelength different from that of the fringe sensing camera. Water vapor in particular is highly dispersive and its effect must be taken into account for high-precision infrared interferometric observations as described previously for VLTI/MIDI or the Keck Interferometer Nuller. In this paper, we describe the new sensing approach that has been developed at the LBT to measure and monitor the optical path length fluctuations due to dry air and water vapor separately. After reviewing the current performance of the system for dry air seeing compensation, we present simultaneous H-, K-, and N-band observations that illustrate the feasibility of our feed forward approach to stabilize the path length fluctuations seen by the LBTI nuller uses a near-infrared camera to measure the optical path length variations between the two AO-corrected apertures and provide high-angular resolution observations for all its science channels (1.5-13 microns). There is however a wavelength dependent component to the atmospheric turbulence, which can introduce optical path length errors when observing at a wavelength different from that of the fringe sensing camera. Water vapor in particular is highly dispersive and its effect must be taken into account for high-precision infrared interferometric observations as described previously for VLTI MIDI or the Keck Interferometer Nuller. In this paper, we describe the new sensing approach that has been developed at the LBT to measure and monitor the optical path length fluctuations due to dry air and water vapor separately. After reviewing the current

  12. How the Laser Helped to Improve the Test of Special Theory of Relativity?

    Science.gov (United States)

    Singh, Satya Pal

    2013-01-01

    In this paper of I have reviewed the test done for validating the special theory of relativity using masers and lasers in last one century. Michelson-Morley did the first experimental verification for the isotropy of space for the propagation of light in 1887. It has an accuracy of 1/100th of a fringe shift. The predicted fringe shift on the basis…

  13. Fidelity of quantum interferometers

    International Nuclear Information System (INIS)

    Bahder, Thomas B.; Lopata, Paul A.

    2006-01-01

    For a generic interferometer, the conditional probability density distribution p(φ|m), for the phase φ given measurement outcome m will generally have multiple peaks. Therefore, the phase sensitivity of an interferometer cannot be adequately characterized by the standard deviation, such as Δφ∼1/√(N) (the standard limit), or Δφ∼1/N (the Heisenberg limit). We propose an alternative measure of phase sensitivity--the fidelity of an interferometer--defined as the Shannon mutual information between the phase shift φ and the measurement outcomes m. As an example application of interferometer fidelity, we consider a generic optical Mach-Zehnder interferometer, used as a sensor of a classical field. For the case where there exists no a priori information on the phase shift, we find the surprising result that maximally entangled state input leads to a lower fidelity than Fock state input, for the same photon number

  14. Fringing field measurement of dipole magnet

    International Nuclear Information System (INIS)

    Lu Hongyou; Jiang Weisheng; Mao Naifeng; Mao Xingwang

    1985-01-01

    The fringing field of a dipole magnet with a C-type circuit and homogeneous field in the gap has been measured including the distributions of fringing fields with and without magnetic shield. The measured data was analyzed by using the concept of virtual field boundary

  15. X-ray interferometers

    International Nuclear Information System (INIS)

    Franks, A.

    1980-01-01

    An improved type of amplitude-division x-ray interferometer is described. The wavelength at which the interferometer can operate is variable, allowing the instrument to be used to measure x-ray wavelength, and the angle of inclination is variable for sample investigation. (U.K.)

  16. Does Gender Influence the Provision of Fringe Benefits?

    DEFF Research Database (Denmark)

    Rand, John; Tarp, Finn

    2011-01-01

    This contribution studies the provision of fringe benefits using a unique survey of small and medium-sized enterprises (SMEs) in Vietnam. Analysis of the survey reveals that women who own SMEs are more likely than men who own similar firms to provide employees with fringe benefits such as annual...... and workforce structure, worker recruitment mechanisms, and the degree of unionization. However, these factors cannot fully account for the observed differences in fringe benefits along the “gender of owner” dimension. There remains a sizable and unexplained fringe benefits premium paid to employees in women...

  17. Handheld White Light Interferometer for Measuring Defect Depth in Windows

    Science.gov (United States)

    Youngquist, Robert; Simmons, Stephen; Cox, Robert

    2010-01-01

    Accurate quantification of defects (scratches and impacts) is vital to the certification of flight hardware and other critical components. The amount of damage to a particular component contributes to the performance, reliability, and safety of a system, which ultimately affects the success or failure of a mission or test. The launch-commit criteria on a Space Shuttle Orbiter window are governed by the depth of the defects that are identified by a visual inspection. This measurement of a defect is not easy to obtain given the environment, size of the defect, and location of the window(s). The determination of depth has typically been performed by taking a mold impression and measuring the impression with an optical profiling instrument. Another method of obtaining an estimate of the depth is by using a refocus microscope. To use a refocus microscope, the surface of the glass and bottom of the defect are, in turn, brought into focus by the operator. The amount of movement between the two points corresponds to the depth of the defect. The refocus microscope requires a skilled operator and has been proven to be unreliable when used on Orbiter windows. White light interferometry was chosen as a candidate to replace the refocus microscope. The White Light Interferometer (WLI) was developed to replace the refocus microscope as the instrument used for measuring the depth of defects in Orbiter windows. The WLI consists of a broadband illumination source, interferometer, detector, motion control, displacement sensor, mechanical housing, and support electronics. The illumination source for the WLI is typically a visible light emitting diode (LED) or a near-infrared superluminescent diode (SLD) with power levels of less than a milliwatt. The interferometer is a Michelson configuration consisting of a 1-in. (2.5-cm) cube beam splitter, a 0.5-in. (1.3-cm) optical window as a movable leg (used to closely match the return intensity of the fixed leg from the window), and a

  18. Carrier introduction to moire pattern for automatic fringe-order distinguishing

    International Nuclear Information System (INIS)

    Fang, J.; Laermann, K.H.

    1992-01-01

    This paper presents an automatic procedure of pseudo-colour encoding of moire fringe orders. A carrier consisting of parallel fringes is introduced before the specimen deforms. The carrier pattern is captured by a camera and then stored in computer as a standard image. The space of the carrier fringes is distored by the strains on the specimen as it is loaded. On a certain condition, the orders of the frequency-modulated carrier still vary monotonically so that they can be easyly distinguished. Both the standard fringe-carrier and the frequency-modulated fringe pattern are transformed into two digital images, of which every fringe is encoded by one of the pseudo-colour codes corresponding to the monotonical fringe orders. At each pixel, the difference between the colour sequences of two images is calculated to obtain the fringe order of pure deformation. The moire pattern of the in-plane displacement is restored as a pseudo-colour image by whose colour-change the variation of the fringe orders is displayed. (orig.)

  19. Colloid mobilization and transport during capillary fringe fluctuations.

    Science.gov (United States)

    Aramrak, Surachet; Flury, Markus; Harsh, James B; Zollars, Richard L

    2014-07-01

    Capillary fringe fluctuations due to changing water tables lead to displacement of air-water interfaces in soils and sediments. These moving air-water interfaces can mobilize colloids. We visualized colloids interacting with moving air-water interfaces during capillary fringe fluctuations by confocal microscopy. We simulated capillary fringe fluctuations in a glass-bead-filled column. We studied four specific conditions: (1) colloids suspended in the aqueous phase, (2) colloids attached to the glass beads in an initially wet porous medium, (3) colloids attached to the glass beads in an initially dry porous medium, and (4) colloids suspended in the aqueous phase with the presence of a static air bubble. Confocal images confirmed that the capillary fringe fluctuations affect colloid transport behavior. Hydrophilic negatively charged colloids initially suspended in the aqueous phase were deposited at the solid-water interface after a drainage passage, but then were removed by subsequent capillary fringe fluctuations. The colloids that were initially attached to the wet or dry glass bead surface were detached by moving air-water interfaces in the capillary fringe. Hydrophilic negatively charged colloids did not attach to static air-bubbles, but hydrophobic negatively charged and hydrophilic positively charged colloids did. Our results demonstrate that capillary fringe fluctuations are an effective means for colloid mobilization.

  20. 26 CFR 1.132-9 - Qualified transportation fringes.

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 2 2010-04-01 2010-04-01 false Qualified transportation fringes. 1.132-9... Qualified transportation fringes. (a) Table of contents. This section contains a list of the questions and answers in § 1.132-9. (1) General rules. Q-1. What is a qualified transportation fringe? Q-2. What is...

  1. Nonlinear refractive index measuring using a double-grating interferometer in pump–probe configuration and Fourier transform analysis

    International Nuclear Information System (INIS)

    Rasouli, Saifollah; Ghorbani, Mahnaz

    2012-01-01

    In this paper, we have presented a simple, stable, highly sensitive and timesaving method based on a double-grating interferometer in conjunction with a pump–probe technique for measuring the nonlinear refractive index. A pump laser beam is aligned collinearly with an expanded plane parallel probe beam by a dichroic mirror. These beams pass through the sample, while right behind the sample using a suitable bandpass filter the pump beam is intercepted. The distorted probe beam then passes through a double-grating interferometer. One of the lateral shearing interference patterns is recorded by use of a CCD camera and, after digitization, has been stored in a computer. The interference pattern is analyzed by means of a Fourier transform algorithm. The refractive index changes have been obtained from phase distribution of the recorded fringe patterns. The implementation of the technique is straightforward and the arrangement is very simple and stable yet its sensitivity is comparable with other interferometry methods. It is also not a time consuming method. The method is applied for measuring the thermal nonlinear refractive index n 2 of colloidal gold nanoparticles in water solution. (paper)

  2. High-frequency background modulation fringe patterns based on a fringe-wavelength geometry-constraint model for 3D surface-shape measurement.

    Science.gov (United States)

    Liu, Xinran; Kofman, Jonathan

    2017-07-10

    A new fringe projection method for surface-shape measurement was developed using four high-frequency phase-shifted background modulation fringe patterns. The pattern frequency is determined using a new fringe-wavelength geometry-constraint model that allows only two corresponding-point candidates in the measurement volume. The correct corresponding point is selected with high reliability using a binary pattern computed from intensity background encoded in the fringe patterns. Equations of geometry-constraint parameters permit parameter calculation prior to measurement, thus reducing measurement computational cost. Experiments demonstrated the ability of the method to perform 3D shape measurement for a surface with geometric discontinuity, and for spatially isolated objects.

  3. A New Light-Speed Anisotropy Experiment: Absolute Motion and Gravitational Waves Detected

    Directory of Open Access Journals (Sweden)

    Cahill R. T.

    2006-10-01

    Full Text Available Data from a new experiment measuring the anisotropy of the one-way speed of EM waves in a coaxial cable, gives the speed of light as 300,000 +/- 400 (+/- 20 km/s in a measured direction RA=5.5 +/- 2 hrs, Dec=70 +/- 10 Deg S, is shown to be in excellent agreement with the results from seven previous anisotropy experiments, particularly those of Miller (1925/26, and even those of Michelson and Morley (1887. The Miller gas-mode interferometer results, and those from the RF coaxial cable experiments of Torr and Kolen (1983, De Witte (1991 and the new experiment all reveal the presence of gravitational waves, as indicated by the last +/- variations above, but of a kind different from those supposedly predicted by General Relativity. Miller repeated the Michelson-Morley 1887 gas-mode interferometer experiment and againdetected the anisotropy of the speed of light, primarily in the years 1925/1926 atop Mt.Wilson, California. The understanding of the operation of the Michelson interferometer in gas-mode was only achieved in 2002 and involved a calibration for the interferometer that necessarily involved Special Relativity effects and the refractive index of the gas in the light paths. The results demonstrate the reality of the Fitzgerald-Lorentz contraction as an observer independent relativistic effect. A common misunderstanding is that the anisotropy of the speed of light is necessarily in conflict with Special Relativity and Lorentz symmetry - this is explained. All eight experiments and theory show that we have both anisotropy of the speed of light and relativistic effects, and that a dynamical 3-space exists - that absolute motion through that space has been repeatedly observed since 1887. These developments completely change fundamental physics and our understanding of reality. Modern vacuum-mode Michelson interferometers, particularly the long baseline terrestrial versions, are, by design flaw, incapable of detecting the anisotropy effect and the

  4. Fringe instability in constrained soft elastic layers.

    Science.gov (United States)

    Lin, Shaoting; Cohen, Tal; Zhang, Teng; Yuk, Hyunwoo; Abeyaratne, Rohan; Zhao, Xuanhe

    2016-11-04

    Soft elastic layers with top and bottom surfaces adhered to rigid bodies are abundant in biological organisms and engineering applications. As the rigid bodies are pulled apart, the stressed layer can exhibit various modes of mechanical instabilities. In cases where the layer's thickness is much smaller than its length and width, the dominant modes that have been studied are the cavitation, interfacial and fingering instabilities. Here we report a new mode of instability which emerges if the thickness of the constrained elastic layer is comparable to or smaller than its width. In this case, the middle portion along the layer's thickness elongates nearly uniformly while the constrained fringe portions of the layer deform nonuniformly. When the applied stretch reaches a critical value, the exposed free surfaces of the fringe portions begin to undulate periodically without debonding from the rigid bodies, giving the fringe instability. We use experiments, theory and numerical simulations to quantitatively explain the fringe instability and derive scaling laws for its critical stress, critical strain and wavelength. We show that in a force controlled setting the elastic fingering instability is associated with a snap-through buckling that does not exist for the fringe instability. The discovery of the fringe instability will not only advance the understanding of mechanical instabilities in soft materials but also have implications for biological and engineered adhesives and joints.

  5. Optical fringe-reflection deflectometry with bundle adjustment

    Science.gov (United States)

    Xiao, Yong-Liang; Li, Sikun; Zhang, Qican; Zhong, Jianxin; Su, Xianyu; You, Zhisheng

    2018-06-01

    Liquid crystal display (LCD) screens are located outside of a camera's field of view in fringe-reflection deflectometry. Therefore, fringes that are displayed on LCD screens are obtained through specular reflection by a fixed camera. Thus, the pose calibration between the camera and LCD screen is one of the main challenges in fringe-reflection deflectometry. A markerless planar mirror is used to reflect the LCD screen more than three times, and the fringes are mapped into the fixed camera. The geometrical calibration can be accomplished by estimating the pose between the camera and the virtual image of fringes. Considering the relation between their pose, the incidence and reflection rays can be unified in the camera frame, and a forward triangulation intersection can be operated in the camera frame to measure three-dimensional (3D) coordinates of the specular surface. In the final optimization, constraint-bundle adjustment is operated to refine simultaneously the camera intrinsic parameters, including distortion coefficients, estimated geometrical pose between the LCD screen and camera, and 3D coordinates of the specular surface, with the help of the absolute phase collinear constraint. Simulation and experiment results demonstrate that the pose calibration with planar mirror reflection is simple and feasible, and the constraint-bundle adjustment can enhance the 3D coordinate measurement accuracy in fringe-reflection deflectometry.

  6. Automated Fringe Pattern Acquisition for Portable Laser Shearography

    International Nuclear Information System (INIS)

    Khairiah Yazid; Mohd Yusnisyam Yusof; Wan Saffiey Wan Abdullah

    2013-01-01

    In shearography system one of the most important tasks is the automatic, fast, reliable processing of the fringe patterns to allow real time inspection. Development of digital CCD cameras, the PC (fast and small data acquisition), high power lasers have led to dramatic performance improvements in shearography instruments and systems. This paper concentrates on development of fringe pattern acquisition using digital CCD camera for portable laser shearography system. A new program for fringe pattern processing which incorporates rapid methods for automatic fringe pattern acquisition and filtering has been developed. The algorithm is written using MATLAB. A graphical user interface with several functions was developed to ensure an easy adaptation in custom applications and providing a flexible way for additional functions. The preliminary results show that the developed algorithm can be used to generate good contrast and reliable fringe pattern. (author)

  7. 29 CFR 1620.11 - Fringe benefits.

    Science.gov (United States)

    2010-07-01

    ... Relating to Labor (Continued) EQUAL EMPLOYMENT OPPORTUNITY COMMISSION THE EQUAL PAY ACT § 1620.11 Fringe... unlawful for an employer to discriminate between men and women performing equal work with regard to fringe... spouses or families of employees of one gender where the same benefits are not made available for the...

  8. Development of a low-cost, 11 µm spectral domain optical coherence tomography surface profilometry prototype

    Science.gov (United States)

    Suliali, Nyasha J.; Baricholo, Peter; Neethling, Pieter H.; Rohwer, Erich G.

    2017-06-01

    A spectral-domain Optical Coherence Tomography (OCT) surface profilometry prototype has been developed for the purpose of surface metrology of optical elements. The prototype consists of a light source, spectral interferometer, sample fixture and software currently running on Microsoft® Windows platforms. In this system, a broadband light emitting diode beam is focused into a Michelson interferometer with a plane mirror as its sample fixture. At the interferometer output, spectral interferograms of broadband sources were measured using a Czerny-Turner mount monochromator with a 2048-element complementary metal oxide semiconductor linear array as the detector. The software performs importation and interpolation of interferometer spectra to pre-condition the data for image computation. One dimensional axial OCT images were computed by Fourier transformation of the measured spectra. A first reflection surface profilometry (FRSP) algorithm was then formulated to perform imaging of step-function-surfaced samples. The algorithm re-constructs two dimensional colour-scaled slice images by concatenation of 21 and 13 axial scans to form a 10 mm and 3.0 mm slice respectively. Measured spectral interferograms, computed interference fringe signals and depth reflectivity profiles were comparable to simulations and correlated to displacements of a single reflector linearly translated about the arm null-mismatch point. Surface profile images of a double-step-function-surfaced sample, embedded with inclination and crack detail were plotted with an axial resolution of 11 μm. The surface shape, defects and misalignment relative to the incident beam were detected to the order of a micron, confirming high resolution of the developed system as compared to electro-mechanical surface profilometry techniques.

  9. VLTI First Fringes with Two Auxiliary Telescopes at Paranal

    Science.gov (United States)

    2005-03-01

    World's Largest Interferometer with Moving Optical Telescopes on Track Summary The Very Large Telescope Interferometer (VLTI) at Paranal Observatory has just seen another extension of its already impressive capabilities by combining interferometrically the light from two relocatable 1.8-m Auxiliary Telescopes. Following the installation of the first Auxiliary Telescope (AT) in January 2004 (see ESO PR 01/04), the second AT arrived at the VLT platform by the end of 2004. Shortly thereafter, during the night of February 2 to 3, 2005, the two high-tech telescopes teamed up and quickly succeeded in performing interferometric observations. This achievement heralds an era of new scientific discoveries. Both Auxiliary Telescopes will be offered from October 1, 2005 to the community of astronomers for routine observations, together with the MIDI instrument. By the end of 2006, Paranal will be home to four operational ATs that may be placed at 30 different positions and thus be combined in a very large number of ways ("baselines"). This will enable the VLTI to operate with enormous flexibility and, in particular, to obtain extremely detailed (sharp) images of celestial objects - ultimately with a resolution that corresponds to detecting an astronaut on the Moon. PR Photo 07a/05: Paranal Observing Platform with AT1 and AT2 PR Photo 07b/05: AT1 and AT2 with Open Domes PR Photo 07c/05: Evening at Paranal with AT1 and AT2 PR Photo 07d/05: AT1 and AT2 under the Southern Sky PR Photo 07e/05: First Fringes with AT1 and AT2 PR Video Clip 01/05: Two ATs at Paranal (Extract from ESO Newsreel 15) A Most Advanced Device ESO PR Video 01/05 ESO PR Video 01/05 Two Auxiliary Telescopes at Paranal [QuickTime: 160 x 120 pix - 37Mb - 4:30 min] [QuickTime: 320 x 240 pix - 64Mb - 4:30 min] ESO PR Photo 07a/05 ESO PR Photo 07a/05 [Preview - JPEG: 493 x400 pix - 44k] [Normal - JPEG: 985 x 800 pix - 727k] [HiRes - JPEG: 5000 x 4060 pix - 13.8M] Captions: ESO PR Video Clip 01/05 is an extract from

  10. Manic fringe is not required for embryonic development, and fringe family members do not exhibit redundant functions in the axial skeleton, limb, or hindbrain

    Science.gov (United States)

    Moran, Jennifer L.; Shifley, Emily T.; Levorse, John M.; Mani, Shyamala; Ostmann, Kristin; Perez-Balaguer, Ariadna; Walker, Dawn M.; Vogt, Thomas F.; Cole, Susan E.

    2009-01-01

    Tight regulation of Notch pathway signaling is important in many aspects of embryonic development. Notch signaling can be modulated by expression of fringe genes, encoding glycosyltransferases that modify EGF repeats in the Notch receptor. Although Lunatic fringe (Lfng) has been shown to play important roles in vertebrate segmentation, comparatively little is known regarding the developmental functions of the other vertebrate fringe genes, Radical fringe (Rfng) and Manic fringe (Mfng). Here we report that Mfng expression is not required for embryonic development. Further, we find that despite significant overlap in expression patterns, we detect no obvious synergistic defects in mice in the absence of two, or all three, fringe genes during development of the axial skeleton, limbs, hindbrain and cranial nerves. PMID:19479951

  11. Towards accurate simulation of fringe field effects

    International Nuclear Information System (INIS)

    Berz, M.; Erdelyi, B.; Makino, K.

    2001-01-01

    In this paper, we study various fringe field effects. Previously, we showed the large impact that fringe fields can have on certain lattice scenarios of the proposed Neutrino Factory. Besides the linear design of the lattice, the effects depend strongly on the details of the field fall off. Various scenarios are compared. Furthermore, in the absence of detailed information, we study the effects for the LHC, a case where the fringe fields are known, and try to draw some conclusions for Neutrino Factory lattices

  12. Pramana – Journal of Physics | Indian Academy of Sciences

    Indian Academy of Sciences (India)

    Measurement of copper vapour laser-induced deformation of dielectric-coated mirror surface by Michelson interferometer · A Wahid S Kundu J S B Singh A K Singh A Khattar S K Maurya J S Dhumal K Dasgupta · More Details Abstract Fulltext PDF. AMichelson interferometer-based technique has been used to measure the ...

  13. Accuracy and high-speed technique for autoprocessing of Young's fringes

    Science.gov (United States)

    Chen, Wenyi; Tan, Yushan

    1991-12-01

    In this paper, an accurate and high-speed method for auto-processing of Young's fringes is proposed. A group of 1-D sampled intensity values along three or more different directions are taken from Young's fringes, and the fringe spacings of each direction are obtained by 1-D FFT respectively. Two directions that have smaller fringe spacing are selected from all directions. The accurate fringe spacings along these two directions are obtained by using orthogonal coherent phase detection technique (OCPD). The actual spacing and angle of Young's fringes, therefore, can be calculated. In this paper, the principle of OCPD is introduced in detail. The accuracy of the method is evaluated theoretically and experimentally.

  14. 26 CFR 1.132-8 - Fringe benefit nondiscrimination rules.

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 2 2010-04-01 2010-04-01 false Fringe benefit nondiscrimination rules. 1.132-8... Fringe benefit nondiscrimination rules. (a) Application of nondiscrimination rules—(1) General rule. A.... (2) Consequences of discrimination—(i) In general. If an employer maintains more than one fringe...

  15. Computer aided fringe pattern analysis

    Science.gov (United States)

    Sciammarella, Cesar A.

    The paper reviews the basic laws of fringe pattern interpretation. The different techniques that are currently utilized are presented using a common frame of reference stressing the fact that these techniques are different variations of the same basic principle. Digital and analog techniques are discussed. Currently available hardware is presented and the relationships between hardware and the operations of pattern fringe processing are pointed out. Examples are given to illustrate the ideas discussed in the paper.

  16. Effect of low-frequency vibrations on speckle interferometry fringes

    International Nuclear Information System (INIS)

    Vikram, C.S.; Pechersky, M.J.

    1998-01-01

    The effects of low-frequency vibrations on speckle correlation fringes have been investigated. The relatively short capture time of the camera in the low-frequency case may yield usable fringe contrast in spite of vibration. It has been shown that the fringes also shift due to the vibration. The study is in agreement with experimental observations of good-contrast correlation fringes even if the object is not on a vibration-isolated table. Some such experimental observations are also presented. copyright 1998 Society of Photo-Optical Instrumentation Engineers

  17. FEATURES OF GEODEFORMATION CHANGES OF NEAR SURFACE SEDIMENTARY ROCKS

    Directory of Open Access Journals (Sweden)

    I. A. Larionov

    2016-11-01

    Full Text Available The results of investigations of the deformation process in the near surface sedimentary rocks, which has been carried out in a seismically active region of Kamchatka peninsular since 2007,are presented. The peculiarity of the experiments on the registration of geodeformations is the application of a laser deformograph-interferometer constructed according to the Michelson interferometer scheme.

  18. Strong time-consistency in the cartel-versus-fringe model

    NARCIS (Netherlands)

    Groot, F.; Withagen, C.A.A.M.; Zeeuw, de A.J.

    2003-01-01

    Due to developments on the oil market in the 1970s, the theory of exhaustible resources was extended with the cartel-versus-fringe model to characterize markets with one big coherent cartel and a large number of small suppliers called the fringe. Because cartel and fringe are leader and follower,

  19. 29 CFR 4.170 - Furnishing fringe benefits or equivalents.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 1 2010-07-01 2010-07-01 true Furnishing fringe benefits or equivalents. 4.170 Section 4... Standards Compliance with Compensation Standards § 4.170 Furnishing fringe benefits or equivalents. (a) General. Fringe benefits required under the Act shall be furnished, separate from and in addition to the...

  20. Modulated Source Interferometry with Combined Amplitude and Frequency Modulation

    Science.gov (United States)

    Gutierrez, Roman C. (Inventor)

    1998-01-01

    An improved interferometer is produced by modifying a conventional interferometer to include amplitude and/or frequency modulation of a coherent light source at radio or higher frequencies. The phase of the modulation signal can be detected in an interfering beam from an interferometer and can be used to determine the actual optical phase of the beam. As such, this improvement can be adapted to virtually any two-beam interferometer, including: Michelson, Mach-Zehnder, and Sagnac interferometers. The use of an amplitude modulated coherent tight source results in an interferometer that combines the wide range advantages of coherent interferometry with the precise distance measurement advantages of white light interferometry.

  1. Phase retrieval from reflective fringe patterns of double-sided transparent objects

    International Nuclear Information System (INIS)

    Huang, Lei; Asundi, Anand Krishna

    2012-01-01

    ‘Ghosted’ fringe patterns simultaneously reflected from both the upper and lower sides of a transparent target in the fringe reflection technique are captured for transparent surface 3D shape measurement, but the phase retrieval from the captured ‘ghosted’ fringe patterns is still not solved. A novel method is proposed to solve this issue by using two sets of phase-shifted fringe patterns with slightly different frequencies. The nonlinear least-squares method is used to estimate the fringe phase and modulation from both front and rear interfaces. Several simulations are done to show the feasibility of the proposed method. The influence of fringe noise on the algorithm is studied as well, which indicates that the proposed method is able to retrieve the phase from double-sided reflective fringe patterns with fringe noise equivalent to that in practical measurements. The merits and limitations of the method are discussed and recommendations for future studies are made. (paper)

  2. Analyzing algorithms for nonlinear and spatially nonuniform phase shifts in the liquid crystal point diffraction interferometer. 1998 summer research program for high school juniors at the University of Rochester's Laboratory for Laser Energetics. Student research reports

    International Nuclear Information System (INIS)

    Jain, N.

    1999-03-01

    Phase-shifting interferometry has many advantages, and the phase shifting nature of the Liquid Crystal Point Diffraction Interferometer (LCPDI) promises to provide significant improvement over other current OMEGA wavefront sensors. However, while phase-shifting capabilities improve its accuracy as an interferometer, phase-shifting itself introduces errors. Phase-shifting algorithms are designed to eliminate certain types of phase-shift errors, and it is important to chose an algorithm that is best suited for use with the LCPDI. Using polarization microscopy, the authors have observed a correlation between LC alignment around the microsphere and fringe behavior. After designing a procedure to compare phase-shifting algorithms, they were able to predict the accuracy of two particular algorithms through computer modeling of device-specific phase shift-errors

  3. 26 CFR 1.61-21 - Taxation of fringe benefits.

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 2 2010-04-01 2010-04-01 false Taxation of fringe benefits. 1.61-21 Section 1... § 1.61-21 Taxation of fringe benefits. (a) Fringe benefits—(1) In general. Section 61(a)(1) provides... vehicle. The fact that another section of subtitle A of the Internal Revenue Code addresses the taxation...

  4. 29 CFR 5.25 - Rate of contribution or cost for fringe benefits.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 1 2010-07-01 2010-07-01 true Rate of contribution or cost for fringe benefits. 5.25... Fringe Benefits Provisions of the Davis-Bacon Act § 5.25 Rate of contribution or cost for fringe benefits... contribution or cost of fringe benefits. Only the amount of contributions or costs for fringe benefits which...

  5. Gaseous effluent monitoring and identification using an imaging Fourier transform spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Carter, M.R.; Bennett, C.L.; Fields, D.J.; Hernandez, J.

    1993-10-01

    We are developing an imaging Fourier transform spectrometer for chemical effluent monitoring. The system consists of a 2-D infrared imaging array in the focal plane of a Michelson interferometer. Individual images are coordinated with the positioning of a moving mirror in the Michelson interferometer. A three dimensional data cube with two spatial dimensions and one interferogram dimension is then Fourier transformed to produce a hyperspectral data cube with one spectral dimension and two spatial dimensions. The spectral range of the instrument is determined by the choice of optical components and the spectral range of the focal plane array. Measurements in the near UV, visible, near IR, and mid-IR ranges are possible with the existing instrument. Gaseous effluent monitoring and identification measurements will be primarily in the ``fingerprint`` region of the spectrum, ({lambda} = 8 to 12 {mu}m). Initial measurements of effluent using this imaging interferometer in the mid-IR will be presented.

  6. Adaptive Optics, LLLFT Interferometry, Astronomy

    National Research Council Canada - National Science Library

    2002-01-01

    We propose to build a three telescope Michelson optical interferometer equipped with wavefront compensation technology as a demonstration and test bed for high resolution Deep Space Surveillance (DSS) and Astronomy...

  7. Special relativity and the Michelson-Morley experiment

    International Nuclear Information System (INIS)

    Chapman, B.R.

    1979-01-01

    It is stated that contrary to most textbook statements about the origins of relativity, there is no real evidence to support the existence of a causal relationship between Michelson's 'crucial' experiment on ether drift and Einstein's enunciation of special relativity. Selective but, it is believed by the author, representative evidence elating to the genesis of the theory of special relativity is presented. Since this evidence contradicts both the substance and the spirit of most textbook references to that genesis, it is thought by the author to have some pedagogic significance for those attempting to teach both the process and the content of physics. (U.K.)

  8. Inpainting for Fringe Projection Profilometry Based on Geometrically Guided Iterative Regularization.

    Science.gov (United States)

    Budianto; Lun, Daniel P K

    2015-12-01

    Conventional fringe projection profilometry methods often have difficulty in reconstructing the 3D model of objects when the fringe images have the so-called highlight regions due to strong illumination from nearby light sources. Within a highlight region, the fringe pattern is often overwhelmed by the strong reflected light. Thus, the 3D information of the object, which is originally embedded in the fringe pattern, can no longer be retrieved. In this paper, a novel inpainting algorithm is proposed to restore the fringe images in the presence of highlights. The proposed method first detects the highlight regions based on a Gaussian mixture model. Then, a geometric sketch of the missing fringes is made and used as the initial guess of an iterative regularization procedure for regenerating the missing fringes. The simulation and experimental results show that the proposed algorithm can accurately reconstruct the 3D model of objects even when their fringe images have large highlight regions. It significantly outperforms the traditional approaches in both quantitative and qualitative evaluations.

  9. Reduction of chromatic aberration influences in vertical scanning white-light interferometry

    International Nuclear Information System (INIS)

    Lehmann, Peter; Kühnhold, Peter; Xie, Weichang

    2014-01-01

    Vertical scanning white-light interferometry (SWLI) is a well-established method that is widely used in high precision surface topography measurement. However, SWLI results show characteristic slope-dependent errors due to dispersion effects and lateral chromatic aberrations of the optical imaging system. In this paper, we present methods to characterize these systematic errors related to dispersion and lateral colour. Lateral colour leads to field-dependent systematic discrepancies of the topography data obtained from the envelope position of a low-coherence interference signal and the data resulting from its interference phase. Hence, an erroneous fringe order obtained from the envelope position leads to a 2π phase jump and thus to a so-called ghost step in the measured topography. Our first approach to solve this problem is based on the measurement of a surface standard of well-known geometry. By comparison of measurement results related to the envelope position and the phase of SWLI signals, the systematic error is estimated and a numerical error compensation method is proposed. Both experimental and simulation results confirm the validity of this numerical method. In addition, using an improved design of a white-light Michelson interferometer we demonstrate experimentally that lateral chromatic aberrations and dispersion influences can be reduced also in a physical way. In this context, a conventional long working distance microscope objective is used which was not originally designed for a Michelson interference microscope. (paper)

  10. Micro analysis of fringe field formed inside LDA measuring volume

    International Nuclear Information System (INIS)

    Ghosh, Abhijit; Nirala, A K

    2016-01-01

    In the present study we propose a technique for micro analysis of fringe field formed inside laser Doppler anemometry (LDA) measuring volume. Detailed knowledge of the fringe field obtained by this technique allows beam quality, alignment and fringe uniformity to be evaluated with greater precision and may be helpful for selection of an appropriate optical element for LDA system operation. A complete characterization of fringes formed at the measurement volume using conventional, as well as holographic optical elements, is presented. Results indicate the qualitative, as well as quantitative, improvement of fringes formed at the measurement volume by holographic optical elements. Hence, use of holographic optical elements in LDA systems may be advantageous for improving accuracy in the measurement. (paper)

  11. 29 CFR 4.174 - Meeting requirements for holiday fringe benefits.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 1 2010-07-01 2010-07-01 true Meeting requirements for holiday fringe benefits. 4.174... Compensation Standards Compliance with Compensation Standards § 4.174 Meeting requirements for holiday fringe benefits. (a) Determining eligibility for holiday benefits—in general. (1) Most fringe benefit...

  12. Standing waves in fiber-optic interferometers

    NARCIS (Netherlands)

    De Haan, V.; Santbergen, R.; Tijssen, M.; Zeman, M.

    2011-01-01

    A study is presented giving the response of three types of fiber-optic interferometers by which a standing wave through an object is investigated. The three types are a Sagnac, Mach–Zehnder and Michelson–Morley interferometer. The response of the Mach–Zehnder interferometer is similar to the Sagnac

  13. Determination of Stress Intensity Factor K1 from Two Fringe Orders by Fringe Multiplication and Sharpening

    International Nuclear Information System (INIS)

    Chen, Lei; Baek, Tae Hyun

    2007-01-01

    Stress intensity factor is one of the most important parameters in fracture mechanics. Both the stress field distribution and the crack propagation are closely related to these parameters. Due to the complexity of actual engineering problems, it is difficult to calculate the stress intensity factor by theoretical formulation, so photoelasticity method is a good choice. In this paper, modified two parameter method is employed to calculate stress intensity factor for opening mode by using data from more than one photoelastic fringe loop. For getting accurate experiment results, the initial fringes are doubled and sharpened by digital image programs from the fringe patterns obtained by a CCD camera. Photoelastic results are compared with those obtained by the use of empirical equation and FEM. Good agreement shows that the methods utilized in experiments are considerably reliable. The photoelastic experiment can be used for bench mark in theoretical study and other experiments

  14. Fringe-projection profilometry based on two-dimensional empirical mode decomposition.

    Science.gov (United States)

    Zheng, Suzhen; Cao, Yiping

    2013-11-01

    In 3D shape measurement, because deformed fringes often contain low-frequency information degraded with random noise and background intensity information, a new fringe-projection profilometry is proposed based on 2D empirical mode decomposition (2D-EMD). The fringe pattern is first decomposed into numbers of intrinsic mode functions by 2D-EMD. Because the method has partial noise reduction, the background components can be removed to obtain the fundamental components needed to perform Hilbert transformation to retrieve the phase information. The 2D-EMD can effectively extract the modulation phase of a single direction fringe and an inclined fringe pattern because it is a full 2D analysis method and considers the relationship between adjacent lines of a fringe patterns. In addition, as the method does not add noise repeatedly, as does ensemble EMD, the data processing time is shortened. Computer simulations and experiments prove the feasibility of this method.

  15. Comparative analysis on some spatial-domain filters for fringe pattern denoising.

    Science.gov (United States)

    Wang, Haixia; Kemao, Qian

    2011-04-20

    Fringe patterns produced by various optical interferometric techniques encode information such as shape, deformation, and refractive index. Noise affects further processing of the fringe patterns. Denoising is often needed before fringe pattern demodulation. Filtering along the fringe orientation is an effective option. Such filters include coherence enhancing diffusion, spin filtering with curve windows, second-order oriented partial-differential equations, and the regularized quadratic cost function for oriented fringe pattern filtering. These filters are analyzed to establish the relationships among them. Theoretical analysis shows that the four filters are largely equivalent to each other. Quantitative results are given on simulated fringe patterns to validate the theoretical analysis and to compare the performance of these filters. © 2011 Optical Society of America

  16. Turbulence-Free Double-slit Interferometer

    Science.gov (United States)

    Smith, Thomas A.; Shih, Yanhua

    2018-02-01

    Optical turbulence can be detrimental for optical observations. For instance, atmospheric turbulence may reduce the visibility or completely blur out the interference produced by an interferometer in open air. However, a simple two-photon interference theory based on Einstein's granularity picture of light makes a turbulence-free interferometer possible; i.e., any refraction index, length, or phase variations along the optical paths of the interferometer do not have any effect on its interference. Applying this mechanism, the reported experiment demonstrates a two-photon double-slit interference that is insensitive to atmospheric turbulence. The turbulence-free mechanism and especially the turbulence-free interferometer would be helpful in optical observations that require high sensitivity and stability such as for gravitational-wave detection.

  17. Time average vibration fringe analysis using Hilbert transformation

    International Nuclear Information System (INIS)

    Kumar, Upputuri Paul; Mohan, Nandigana Krishna; Kothiyal, Mahendra Prasad

    2010-01-01

    Quantitative phase information from a single interferogram can be obtained using the Hilbert transform (HT). We have applied the HT method for quantitative evaluation of Bessel fringes obtained in time average TV holography. The method requires only one fringe pattern for the extraction of vibration amplitude and reduces the complexity in quantifying the data experienced in the time average reference bias modulation method, which uses multiple fringe frames. The technique is demonstrated for the measurement of out-of-plane vibration amplitude on a small scale specimen using a time average microscopic TV holography system.

  18. Study of moire fringes using synchrotron X-rays

    International Nuclear Information System (INIS)

    Yoshimura, Jun-ichi

    1992-01-01

    It has recently been shown that X-ray moire fringes are not exactly the projection of the intensity distribution of the wave field on the exit surface of the crystal, but do oscillate along the beam path behind the crystal. Such nonprojectiveness of moire fringes is inexplicable by the conventional understanding of moire fringes, and therefore is of interest from a fundamental viewpoint as well as practical one. In this paper the phenomena of the nonprojectiveness are described on the basis of the latest experimental data obtained by synchrotron radiation. (author)

  19. Design of a nano-satellite demonstrator of an infrared imaging space interferometer: the HyperCube

    Science.gov (United States)

    Dohlen, Kjetil; Vives, Sébastien; Rakotonimbahy, Eddy; Sarkar, Tanmoy; Tasnim Ava, Tanzila; Baccichet, Nicola; Savini, Giorgio; Swinyard, Bruce

    2014-07-01

    algorithm for design of optimal aperture layout based on least-squares minimization is described. A first experimental setup realized by master students is presented, where a 20mm baseline interferometer with 1mm apertures associated with a thermal infrared camera pointed the sun. The absence of fringes in this setup is discussed in terms of spatial spectrum analysis. Finally, we discuss requirements in terms of satellite pointing requirements for such a miniature interferometer.

  20. A Core-Offset Mach Zehnder Interferometer Based on A Non-Zero Dispersion-Shifted Fiber and Its Torsion Sensing Application

    Directory of Open Access Journals (Sweden)

    Eduardo Huerta-Mascotte

    2016-06-01

    Full Text Available In this paper, an all-fiber Mach-Zehnder interferometer (MZI based on a non-zero dispersion-shifted fiber (NZ-DSF is presented. The MZI was implemented by core-offset fusion splicing one section of a NZ-DSF fiber between two pieces of single mode fibers (SMFs. Here, the NZ-DSF core and cladding were used as the arms of the MZI, while the core-offset sections acted as optical fiber couplers. Thus, a MZI interference spectrum with a fringe contrast (FC of about 20 dB was observed. Moreover, its response spectrum was experimentally characterized to the torsion parameter and a sensitivity of 0.070 nm/° was achieved. Finally, these MZIs can be implemented in a compact size and low cost.