WorldWideScience

Sample records for mica cr-39 polymer

  1. Alkaline erosion of CR 39 polymer surfaces

    International Nuclear Information System (INIS)

    Faiman, Laurence

    2009-01-01

    We have investigated the mechanism of erosion of CR 39 polymer in alkaline environments. We observed the kinetics of absorption of water and methanol into both unirradiated and γ-irradiated samples. We use a capillary model to interpret our results. We etched our samples in both KOH solutions, and KOH solutions doped with methanol. Etch rate was desensitizing to γ-irradiation when KOH concentration approached saturation, but KOH solutions doped with methanol were not desensitizing, unlike with nuclear tracks. We account for this difference

  2. Characteristics of latent damage trails due to high energy 208Pb and 238U ions in CR-39 and muscovite mica

    International Nuclear Information System (INIS)

    Chohan, A.S.; Akhtar, S.M.

    1988-01-01

    Experiments have been performed to study the characteristics of latent damage trails produced by (a) 17.14 MeV/nucleon- 208 Pb ions in mica and CR-39 track detectors and (b) 13.7 MeV/nucleon- 238 U in CR-39 track detectors. The parameters studied include (a) V t , average etching velocity along the track, (b) thermal stability of the latent damage trails, (c) the total etchable ranges, and (d) V g the general etching velocity of CR-39 track detectors previously annealed at different temperatures. It has been observed that the latent damage trails in CR-39 are greatly affected at temperatures around 200 0 C in CR-39 track detectors. The general etching velocity of a CR-39 detector has been found to increase with increasing annealing temperatures. (author)

  3. Thermal degradation of CR-39 polymer in an inert atmosphere

    International Nuclear Information System (INIS)

    Kalsi, P.C.; Pandey, A.K.; Iyer, R.H.; Singh Mudher, K.D.

    1995-01-01

    The thermal degradation of CR-39 (allyl diglycol carbonate), a polymer widely used in nuclear science and technology, in an inert atmosphere has been studied using thermogravimetric analysis (TGA) and differential thermal analysis (DTA) techniques. The results are compared with the thermal degradation data of the polymer in an air atmosphere. The present studies showed that the thermal degradation of the polymer proceeds in two steps in an argon atmosphere as compared to three steps in air atmosphere. The mass losses in air are higher than that in argon due to the oxidative decomposition of the residue. The kinetics of the different stages of degradation were also evaluated from the TG curves. (author). 7 refs., 1 tab

  4. Sensitivity of chemically and electrochemically etched CR 39 polymers to the neutrons of AmBe source

    International Nuclear Information System (INIS)

    Turek, K.; Spurny, F.; Dajko, G.; Somogyi, G.

    1981-01-01

    Seven samples of polymers by different manufacturers were used in a study of the sensitivity of CR 39 polymers to Am-Be neutrons. In the polymer, proton tracks for a relatively broad energy range can also be recorded. The following characteristics were studied: the sample background for different etching methods, the dependence of sensitivity on the etched thickness and on neutron fluence, the effect of type and thickness of external proton emitters, and the effect of the choice of electric parameters on the resulting sensitivity in electrochemical etching. Good results were obtained when chemical and electrochemical etching was used in combination. It was found that with electrochemical etching, sensitivity decreases for neutron fluence exceeding 10 8 cm -2 . The sensitivity of the studied CR 39 polymer samples only little differed. When the most sensitive polymer was used, the minimum dose equivalent in the human body for Am-Be neutrons which could be determined using combination etching was 0.4 mSv (ie., 40 mrems). (B.S.)

  5. Radon diffusion in polymer vessels using CR-39 solid state nuclear track detector

    Energy Technology Data Exchange (ETDEWEB)

    Carneiro, Andre Cavalcanti; Menezes, Maria Angela de B.C.; Rocha, Zildete; Pereira, Marcio Tadeu, E-mail: andreccarneiro@gmail.com, E-mail: menezes@cdtn.br, E-mail: zildete@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Santos, Talita de Oliveira; Lara, Evelise Gomes; Braga, Mario Roberto Martins S.S., E-mail: mariomartins@gmail.com, E-mail: evelise.lara@gmail.com, E-mail: talitaolsantos@yahoo.com.br [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil)

    2015-07-01

    At CDTN/CNEN, the method to determine {sup 226}Ra in several matrices by gamma spectrometry is already established; however, the method should be improved. This paper is about the first step of this improvement. Several polymer vessels were studied verifying the effect of radiolysis on the walls of the vessel. A test about the diffusion of {sup 222}Rn through the walls was carried out using the CR-39 solid state nuclear track detector. The results pointed out that the vessel made up by acrylic material is the best candidate to replace the vessel actually used. (author)

  6. A study of the molecular structure in CR-39

    International Nuclear Information System (INIS)

    Stejny, J.; Portwood, T.

    1986-01-01

    A technique is presented for examining the molecular structure of CR-39 by analysis of the etch products from hydrolysis of the polymer network. The CR-39 network consists of polyallyl chains jointed by diethyleneglycol dicarbonate links. The etching cuts the carbonate links and liberates the polyallyl chains which makes them amenable to common analytical methods. Gel Permeation Chromatography was used to characterize the chain lengths and their distribution. It was found that the average length is rather short and that it decreases with increasing concentration of the initiator. This technique has been also used to identify the radiation sensitive link in the CR-39 network. It was found that the length of polyallyl chain is not changed in 60 Co γ-irradiated plastic while the etch rate significantly increases. This shows that the polyallyl chains are relatively inert and not responsible for the radiation sensitivity of CR-39 and that it is the diethyleneglycol dicarbonate links which are damaged by radiation. (author)

  7. Gamma irradiation effects on the thermal, optical and structural properties of Cr-39 nuclear track detector

    International Nuclear Information System (INIS)

    Nouh, S.A.; Said, A.F.; Atta, M.R.; EL-Mellegy, W.M.; EL-Meniawi, S.

    2006-01-01

    A study of the effect of gamma irradiation on the thermal, optical and structural properties of CR-39 diglycol carbonate solid state nuclear track detector (SSNTD) has been carried out. Samples from CR-39 polymer were irradiated with gamma doses at levels between 20 and 300 KGy. Non-isothermal studies were carried out using thermo-gravimetry (TG), differential thermo-gravimetry (DTG) and differential thermal analysis (DTA) to obtain the activation energy of decomposition and the transition temperatures for the non-irradiated and irradiated CR-39 samples. In addition, optical and structural property studies were performed on non-irradiated and irradiated CR-39 samples using refractive index and X-ray diffraction measurements. The variation of onset temperature of decomposition (To) thermal activation energy of decomposition (Ea) melting temperature (Tm) refractive index (n) and the mass fraction of the amorphous phase with the gamma dose were studied. It was found that many changes in the thermal, optical and structural properties of the CR-39 polymer could be produced by gamma irradiation via the degradation and cross linking mechanisms. Also, the gamma dose gave an advantage for increasing the correlation between the thermal stability of CR-39 polymer and the bond formation created by the ionizing effect of gamma radiation

  8. Mass spectrometry analysis of etch products from CR-39 plastic irradiated by heavy ions

    Science.gov (United States)

    Kodaira, S.; Nanjo, D.; Kawashima, H.; Yasuda, N.; Konishi, T.; Kurano, M.; Kitamura, H.; Uchihori, Y.; Naka, S.; Ota, S.; Ideguchi, Y.; Hasebe, N.; Mori, Y.; Yamauchi, T.

    2012-09-01

    As a feasibility study, gas chromatography-mass spectrometry (GC-MS) and matrix-assisted laser desorption ionization-mass spectrometry (MALDI-MS) have been applied to analyze etch products of CR-39 plastic (one of the most frequently used solid states nuclear track detector) for the understanding of track formation and etching mechanisms by heavy ion irradiation. The etch products of irradiated CR-39 dissolved in sodium hydroxide solution (NaOH) contain radiation-induced fragments. For the GC-MS analysis, we found peaks of diethylene glycol (DEG) and a small but a definitive peak of ethylene glycol (EG) in the etch products from CR-39 irradiated by 60 MeV N ion beams. The etch products of unirradiated CR-39 showed a clear peak of DEG, but no other significant peaks were found. DEG is known to be released from the CR-39 molecule as a fragment by alkaline hydrolysis reaction of the polymer. We postulate that EG was formed as a result of the breaking of the ether bond (C-O-C) of the DEG part of the CR-39 polymer by the irradiation. The mass distribution of polyallylalcohol was obtained from the etch products from irradiated and unirradiated CR-39 samples by MALDI-MS analysis. Polyallylalcohol, with the repeating mass interval of m/z = 58 Da (dalton) between m/z = 800 and 3500, was expected to be produced from CR-39 by alkaline hydrolysis. We used IAA as a matrix to assist the ionization of organic analyte in MALDI-MS analysis and found that peaks from IAA covered mass spectrum in the lower m/z region making difficult to identify CR-39 fragment peaks which were also be seen in the same region. The mass spectrometry analysis using GC-MS and MALDI-MS will be powerful tools to investigate the radiation-induced polymeric fragments and helping to understand the track formation mechanism in CR-39 by heavy ions.

  9. The effect of solarradiation and UV photons on the CR-39 nuclear track detector

    International Nuclear Information System (INIS)

    Saad, A.F.

    2003-01-01

    The effects induced in the CR-39 polymer detector by total solar radiation (TSR) and UV photons were investigated. Thr exposure of detector samples to solar photons was carried out according to certain conditions. The TSR exposure period started in the middle of july and lasted unitel 12 th of september. 2000: the hottest months in zagazig, egypt. Another set of detector samples was exposed to UV photons from a UV lamp for different intervals. After UV exposure, these detectors were analysed with an FT-IR sepectrometer of jasco type 5300 in transmission mode. The FT-IR spectra does not show any considerable modifications due to UV irradiation in that detector. The effects of UV light were compared with those of solar radiation containing ultraviolet photons , on the registration properties of this polymer detector. Preliminaryresults revealed a proportionate increase in bluk etch rate of CR-39 detector with the increase of exposure time to the solar radiation. The results indicated that the CR-39 polymer detector can be used as a solar radiation dosimeter

  10. Is CR39 worth the effort?

    International Nuclear Information System (INIS)

    Griffith, R.V.

    1987-01-01

    CR39 proton sensitive track detectors were greeted by the radiation protection community at the end of the last decade as a major breakthrough for personnel neutron dosimetry. A number of laboratories eagerly began research on application of CR39 to their dosimetry needs. However, in the last two or three years the enthusiasm has subsided, and many health physicists have stopped working with the material. The number of participants using CR39 in the Oak Ridge National Laboratory Personnel Intercomparison Studies dropped from six in 1985 to three in 1986. On a national level, the Federal Republic of Germany with researchers active in CR39 research recently adopted an albedo system as their national standard. In contrast, the United States Department of Energy (DOE) is supporting development of a CR39 based combination dosimeter to meet Department wide dosimetry needs. The English National Radiological Protection Board (NRPB) now features the use of CR39 in the NRPB PADC(CR39). There has obviously been a range of experiences with CR39 in the dosimetry community. Why has this been the case, and what is the proper role for CR39 in personnel neutron dosimetry. 12 refs., 2 figs., 1 tab

  11. Study of the optical properties and the carbonaceous clusters in thermally-annealed CR-39 and Makrofol-E polymer-based solid-state nuclear track detectors

    International Nuclear Information System (INIS)

    El Ghazaly, M.

    2012-01-01

    The induced modifications in the optical properties of CR-39 and Makrofol-E polymer-based solid state nuclear track detectors were investigated after thermal annealing at a temperature of 200 .deg. C for different durations. The optical properties were studied using an UV-visible spectrophotometer. From the UV-visible spectra, the direct and the indirect optical band gaps, Urbach's energies, and the number of carbon atoms in a cluster were determined. The absorbance of CR-39 plastic detector was found to decrease with increasing annealing time while the absorbance of Makrofol-E decreased with increasing annealing time. The width of the tail of localized states in the band gap ΔE was evaluated with the Urbach method. The optical energy band gaps were obtained from the direct and the indirect allowed transitions in K-space. Both of the direct and the indirect band gaps of the annealed CR-39 detector decrease with increasing annealing time while in Makrofol-E, they decreased after an annealing time of 15 minute and then showed no remarkable changes for a prolonged annealing times. Urbach's energy decreased significantly for both CR-39 and Makrofol-E with increasing annealing time. The number of carbon atoms in a cluster increased in the CR-39 detector with increasing annealing time while it decreased with increasing annealing time for Makrofol-E. We may conclude that the CR-39 detector undergoes greater modifications than the Makrofol-E detector upon thermal annealing at 200 .deg. C. In conclusion, the induced modifications in the optical properties of CR-39 and Makrofol-E are correlated with the temperature and the duration of annealing.

  12. Ablation and cone formation mechanism on CR-39 by ArF laser irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Shakeri Jooybari, B., E-mail: baninshakery@gmail.com, E-mail: hafarideh@aut.ac.ir [Department of Energy Engineering and Physics, Amirkabir University of Technology, P.O. Box 15875-4413, Tehran, Islamic Republic of Iran (Iran, Islamic Republic of); Nuclear Science and Technology Research Institute NSRT, Tehran (Iran, Islamic Republic of); Afarideh, H., E-mail: baninshakery@gmail.com, E-mail: hafarideh@aut.ac.ir [Department of Energy Engineering and Physics, Amirkabir University of Technology, P.O. Box 15875-4413, Tehran, Islamic Republic of Iran (Iran, Islamic Republic of); Lamehi-Rachti, M. [Nuclear Science and Technology Research Institute NSRT, Tehran (Iran, Islamic Republic of); Ghergherehchi, M. [Department of Energy Engineering and Physics, Amirkabir University of Technology, P.O. Box 15875-4413, Tehran, Islamic Republic of Iran (Iran, Islamic Republic of); College of Information and Communication Engineering, Sungkyunkwan University, Suwon (Korea, Republic of)

    2015-03-07

    In this work, chemical properties, surface modification, and micro structures formation on ablated polyallyl di-glycol carbonate (CR-39) polymer by ArF laser irradiation (λ = 193 nm) at various fluences and pulse number were investigated. CR-39 samples have been irradiated with an ArF laser (193 nm) at a repetition rate of 1 Hz. Threshold fluence of ablation and effective absorption coefficient of CR-39 were determined. Conical microstructures (Taylor cone) formed on laser-ablated CR-39 exhibit: smooth, Taylor cone shape walls and sharp tips together with interference and well defined fringe-structure with a period of 230 nm, around cone base. Mechanism of cone formation and cone evolution of CR-39 ablated surface were investigated by change of fluences (at a given pulse number) and pulse number (at a given fluence). Cone height, cone base, and region of interface were increased in micrometer steps by increasing the total fluence. Depression on the base of the cone and the circular fringe were simulated. FTIR spectra were measured and energy dispersive x-ray analysis of irradiated and un-irradiated samples was performed.

  13. Neutron dosimeter utilizing CR-39

    International Nuclear Information System (INIS)

    Souza, H.V.C. de.

    1991-05-01

    A personnel neutron dosimeter has been developed with discretization in a wide range of energies of real interest, utilizing the CR-39 polymer, to detect recoil protons in the fast range, and alpha particles in the thermal and epithermal ranges, with possibility to be disposed in the IRD/CNEN's conventional film badge suport. They are presented, abstractly, the difficulties and importance of the neutron dosimetry, beyond the general objectives that motivated this work execution. The details of the materials utilized in the dosimeter confection, and the experimental methodology employed to obtain the performance curves are presented. The results about linearity response of the dosimeter with respect to equivalent dose, in a wide range of doses, and about the verified angular dependence are analysed. (author)

  14. Modifications in the optical and thermal properties of a CR-39 polymeric detector induced by high doses of γ-radiation

    Science.gov (United States)

    Saad, A. F.; Ibraheim, Mona H.; Nwara, Aya M.; Kandil, S. A.

    2018-04-01

    Effects of γ-radiation on the optical and thermal properties of a poly allyl diglycol carbonate (PADC), a form of CR-39, polymer have been investigated. CR-39 detectors were exposed to γ-rays at very high doses ranging from 5.0 × 105 to 3.0 × 106 Gy. The induced changes were analyzed using ultraviolet-visible spectroscopy (UV-VIS) in absorbance mode, and thermogravimetric analysis (TGA). The UV-visible spectra of the virgin and γ-irradiated CR-39 polymer detectors displayed a significant decreasing trend in their optical energy band gaps for indirect transitions, whereas for the direct ones showed a little change. This drop in the energy band gap with increasing dose is discussed on the basis of the gamma irradiation induced modifications in the CR-39 polymeric detector. The TGA thermograms show that the weight loss rate increased with increase in dose, which may be due to the disordered system via scission followed by crosslinking in the irradiated polymer detector. The TGA thermograms also indicated that the CR-39 detector decomposed in three/four stages for the virgin and irradiated samples. The activation energy for thermal decomposition was determined using a type of Arrhenius equation based on the TGA experimental results. These experimental results so obtained can be well used in radiation dosimetry.

  15. Electrochemical development of particle tracks in CR-39 polymer dosimeter

    International Nuclear Information System (INIS)

    Hadlock, D.E.; Parkhurst, M.A.; Yang, C.S.; Groeger, J.; Johnson, J.R.; Huang, S.J.

    1985-09-01

    Electrochemical etching of CR-39 polymeric track etch neutron detectors results in proton-recoil tracks can be distinguished from background tracks much better than tracks developed solely by chemical etching. A newly designed and constructed electrochemical etching apparatus allows large numbers of dosimeters to be processed simultaneously with consistent results. Many processing systems have been developed for chemical and electrochemical etching of the track etch dosimeters. Three systems specifically show great promise and are being studied extensively

  16. CR-39 (PADC) Reflection and Transmission of Light in the Ultraviolet-Near-Infrared (UV-NIR) Range.

    Science.gov (United States)

    Traynor, Nathan B J; McLauchlin, Christopher; Dodge, Kenneth; McGarrah, James E; Padalino, Stephen J; McCluskey, Michelle; Sangster, T C; McLean, James G

    2018-04-01

    The spectral reflection (specular and diffuse) and transmission of Columbia Resin 39 (CR-39) were measured for incoherent light with wavelengths in the range of 200-2500 nm. These results will be of use for the optical characterization of CR-39, as well as in investigations of the chemical modifications of the polymer caused by ultraviolet (UV) exposure. A Varian Cary 5000 was used to perform spectroscopy on several different thicknesses of CR-39. With proper analysis for the interdependence of reflectance and transmittance, results are consistent across all samples. The reflectivity from each CR-39-air boundary reveals an increase in the index of refraction in the near-UV. Absorption observations are consistent with the Beer-Lambert law. Strong absorption of UV light of wavelength shorter than 350 nm suggests an optical band gap of 3.5 eV, although the standard analysis is not conclusive. Absorption features observed in the near infrared are assigned to molecular vibrations, including some that are new to the literature.

  17. Advances in the development of Cr-39 based neutron dosimeters

    International Nuclear Information System (INIS)

    Hadlock, D.E.; Parkhurst, M.A.

    1987-12-01

    A combination thermoluminescent dosimeter (TLD) and track etch dosimeter (TED), which can be used for detecting neutrons over a wide energy range, has been developed through recent research in passive neutron dosimetery. This dosimeter uses Li-600 TLDs to detect thermal and low energy neutrons reflected from the body, and the TED polymer of CR-39, to detect fast neutrons from proton recoil interactions with the polyethylene radiator or with CR-39 itself. Some form of the combination dosimeter is currently in use at several US Department of Energy (DOE) facilities, and its use is expected to expand over the next year to include all DOE facilities where significant neutron exposures may occur. The extensive research conducted on the TED component over the past six years has continually focused on material improvements, reduction in processing time and dosimeter handling, and ease of sample readout with the goal of automating the process as much as possible. 1 fig

  18. Characterization of saturation of CR-39 detector at high alpha-particle fluence

    Directory of Open Access Journals (Sweden)

    M. El Ghazaly

    2018-04-01

    Full Text Available The occurrence of saturation in the CR-39 detector reduces and limits its detection dynamic range; nevertheless, this range could be extended using spectroscopic techniques and by measuring the net bulk rate of the saturated CR-39 detector surface. CR-39 detectors were irradiated by 1.5 MeV high alpha-particle fluence varying from 0.06 × 108 to 7.36 × 108 alphas/cm2 from Am-241 source; thereafter, they were etched in a 6.25N NaOH solution at a temperature of 70°C for different durations. Net bulk etch rate measurement of the 1.5 MeV alpha-irradiated CR-39 detector surface revealed that rate increases with increasing etching time and reaches its maximum value at the end of the alpha-particle range. It is also correlated with the alpha-particle fluence. The measurements of UV–Visible (UV–Vis absorbance at 500 and 600 nm reveal that the absorbance is linearly correlated with the fluence of alpha particles at the etching times of 2 and 4 hour. For extended etching times of 6, 10, and 14.5 hour, the absorbance is saturated for fluence values of 4.05 × 108, 5.30 × 108, and 7.36 × 108 alphas/cm2. These new methods pave the way to extend the dynamic range of polymer-based solid state nuclear track detectors (SSNTDs in measurement of high fluence of heavy ions as well as in radiation dosimetry. Keywords: Alpha Particle, Bulk Etch Rate, CR-39 Detector, Saturated Regime, UV–Vis Spectroscopy

  19. LET calibration for CR-39 detectors in different oxygen environments

    International Nuclear Information System (INIS)

    Zhou, D.; Semones, E.; Weyland, M.; Benton, E.R.

    2007-01-01

    High LET (linear energy transfer) radiation is the main contributor to the radiation field in low Earth orbit (LEO) in terms of dose equivalent. CR-39 plastic nuclear track detectors (PNTDs) can measure the LET spectrum and charge spectrum for the complicated radiation field in space. Previous research indicated that the sensitivity of CR-39 is different for CR-39 PNTDs working in different oxygen environments. LET calibration for CR-39 detectors in different oxygen environments is needed. Almost all the previous LET calibration work was carried out for CR-39 detectors in good-oxygen condition, LET calibration work for CR-39 in poor-oxygen condition has not been conducted until our work. Systematic LET calibrations were carried out by JSC-SRAG (Space Radiation Analysis Group) for CR-39 detectors working in different oxygen environments and abundant results of LET calibrations were obtained. This paper introduces the method for CR-39 LET calibration, presents and discusses the calibration results and some applications

  20. STUDYING THE STRUCTURAL, OPTICAL, CHEMICAL AND ELECTROCHEMICAL ETCHING CHANGES OF CR-39 FOR DOSEMETRIC APPLICATIONS.

    Science.gov (United States)

    Zaki, M F; Elshaer, Y H; Taha, Doaa H

    2017-12-01

    The present work shows the induced modification of the structural, optical, chemical etching and electrochemical etching parameters of CR-39 irradiated with alpha-particles. CR-39 polymer track detectors were irradiated with different fluences (1.62 × 106, 2.72 × 106, 3.82 × 106 and 5.21 × 106 particles/cm2) of alpha-particles using 241Am source. The structural and optical properties were measured by FT-IR spectroscopy, X-ray diffraction and UV/Vis spectroscopy, respectively. The FT-IR spectra reveal that no major changes in the typical functional groups of irradiated polymer detectors. The X-ray diffraction patterns show that a broad band in the region of 12° 27°, which refers to the presence of the combination of amorphous and crystalline phases. UV/Vis responses of irradiated polymer track detectors exhibit a single absorption band in the range of 254-352 nm that is correlated to the occurrence of electronic transition. Also, the changes in the chemical and electrochemical parameters due to alpha-irradiation are examined and thoroughly discussed. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  1. CR-39 as induced track detector in reactor: irradiation effect

    International Nuclear Information System (INIS)

    Zylberberg, H.

    1989-07-01

    A systematic study about reactor's neutrons radiation effect and gamma radiation effect on the properties of CR-39 that are significant for its use as induced fission track detector is showed. The following studies deserved attention: kinetics of the fission track chemical development; efficiency to register and to develop fission track; losses of developable tracks; variation in the number of developable tracks and variation in the visible and ultraviolet radiation spectrum. The dissertation is organized in seven specific chapters: solid state nuclear tracks (SSNT); CR-39 as SSNT; objectives and problems presentation; preparation and characterization of CR-39 as SSNT; gamma irradiation effect on the properties of CR-39 as SSNT; reactor neutron irradiation effect on the properties of CR-39 as SSNT and, results discussions and conclusions. The main work contributions are the use of CR-39 in the determination of fissionable nuclide as thorium and uranium in solid and liquid samples; gamma radiation damage on CR-39 as well as the reactor's neutron damage on CR-39. (B.C.A.) 62 refs, 53 figs, 21 tabs

  2. Investigations of CR39 dosimeters for neutron routine dosimetry

    International Nuclear Information System (INIS)

    Weinstein, M.; Abraham, A.; Tshuva, A.; German, U.

    2004-01-01

    CR-39 is a polymeric nuclear track detector which is widely used for neutron dosimetry. CR-39 detector development was conducted at a number of laboratories throughout the world(1,2) , and was accepted also for routine dosimetry. However, there are shortcomings which must be taken into consideration the lack of a dosimetry grade material which causes batch variations, significant angular dependence and a moderate sensitivity. CR-39 also under-responds for certain classes of neutron spectra (lower energy neutrons from reactors or high energy accelerator-produced neutrons).In order to introduce CR-39 as a routine dosimeter at NRCN, a series of checks were performed. The present work describes the results of some of our checks, to characterize the main properties of CR-39 dosimeters

  3. Optimization of CR-39 for fast neutron dosimetry applications

    International Nuclear Information System (INIS)

    Vilela, E.; Fantuzzi, E.; Giacomelli, G.; Giorgini, M.; Morelli, B.; Patrizii, L.; Serra, P.; Togo, V.

    1999-01-01

    We present the results of an experimental work aimed at improving the performances of the CR-39[reg] (Registered Trademark of PPG Industries Inc.) nuclear track detector for neutron dosimetry applications. The work was done in collaboration with the Intercast Europe S.p.A., producer of CR-39 for commercial and scientific applications. We compare the CR-39 made with different additives concentrations and different polymerization processes. We evaluate the response of the CR-39 to fast neutrons from three sources: 241 Am-Be, 252 Cf and 238 Pu-Li. Particular attention was paid to background fluctuations that limit the lower detectable dose

  4. Optimization of CR-39 for fast neutron dosimetry applications

    CERN Document Server

    Vilela, E; Giacomelli, G; Giorgini, M; Morelli, B; Patrizii, L; Serra, P; Togo, V

    1999-01-01

    We present the results of an experimental work aimed at improving the performances of the CR-39[reg] (Registered Trademark of PPG Industries Inc.) nuclear track detector for neutron dosimetry applications. The work was done in collaboration with the Intercast Europe S.p.A., producer of CR-39 for commercial and scientific applications. We compare the CR-39 made with different additives concentrations and different polymerization processes. We evaluate the response of the CR-39 to fast neutrons from three sources: sup 2 sup 4 sup 1 Am-Be, sup 2 sup 5 sup 2 Cf and sup 2 sup 3 sup 8 Pu-Li. Particular attention was paid to background fluctuations that limit the lower detectable dose.

  5. Cr-39 fast neutron dosemeter based on A (n, α) converter

    International Nuclear Information System (INIS)

    Widayati, S.; Budiantari, T.

    1998-01-01

    The aim of this experiment is to obtained the response of Cr-39 as fast neutron dosemeter based on an (n, α) converter. Cr-39 was irradiated to AmBe fast neutron flux from 0.10 mSv to 2.5 mSv. Cr-39 processed by chemical etching with NaOH 20 % at temperature of 60 oC in six hours. The results of experiment showed that the response of Cr-39 based on an (n, α) converter is 6 times bigger than the response of Cr-39 without (n, α) converter. (author)

  6. The LLNL CR-39 personnel neutron dosimeter

    International Nuclear Information System (INIS)

    Hankins, D.E.; Homann, S.; Westermark, J.

    1987-01-01

    We developed a personnel neutron dosimetry system based on the electrochemical etching of CR-39 plastic at elevated temperatures. The doses obtained using this dosimeter system are more accurate than those obtained using other dosimetry systems, especially when varied neutron spectra are encountered. This CR-39 dosimetry system does not have the severe energy dependence that exists with albedo neutron dosimeters or the fading and reading problems encountered with NTA film. 3 refs., 4 figs

  7. High energy charged particle registration in CR-39 polycarbonated detector

    International Nuclear Information System (INIS)

    Abdel-Wahab, M.S.; El Enany, N.; El Fiki, S.; Eissa, H.M.; El-Adl, E.H.; El-Feky, M.A.

    1991-01-01

    Track etch rate characteristics of CR-39 plastic detector exposed to 28 Si ions of 670 MeV energy have been investigated. Experimental results were obtained in terms of frequency distribution of the track diameter, track density and bulk etching rate. A dependence of the mean track diameter on energy was found. The application of the radiation effect of heavy ions on CR-39 in the field of radiation detection and dosimetry are discussed. Results indicated that it is possible to produce etchable tracks of 28 Si in this energy range in CR-39. We also report the etching characteristics of these tracks in the CR-39 detector. (orig.) [de

  8. CR-39 track detector for multi-MeV ion spectroscopy.

    Science.gov (United States)

    Jeong, T W; Singh, P K; Scullion, C; Ahmed, H; Hadjisolomou, P; Jeon, C; Yun, H; Kakolee, K F; Borghesi, M; Ter-Avetisyan, S

    2017-05-19

    We present the characteristics of track formation on the front and rear surfaces of CR-39 produced by laser-driven protons and carbon ions. A methodological approach, based on bulk etch length, is proposed to uniquely characterize the particle tracks in CR-39, enabling comparative description of the track characteristics in different experiments. The response of CR-39 to ions is studied based on the energy dependent growth rate of the track diameter to understand the intrinsic particle stopping process within the material. A large non-uniformity in the track diameter is observed for CR-39 with thickness matching with the stopping range of particles. Simulation and experimental results show the imprint of longitudinal range straggling for energetic protons. Moreover, by exploiting the energy dependence of the track diameter, the energy resolution (δE/E) of CR-39 for few MeV protons and Carbon ion is found to be about 3%.

  9. A study on alpha particles range in Cr-39

    International Nuclear Information System (INIS)

    Ibrahim, Z.A.; Talaat, T.M.; Abdel-Aziz, Kh.M.A.; El-Asser, M.R.

    2000-01-01

    Cr-39 plastic nuclear track detector has been used in range determination of alpha particles. A set of experiments was carried out for studying alpha energy and track diameter relationships. This work was done under the optimum conditions of Cr-39 etching in 6.25 N NaOH at 70 degree C for various etching times. Determination of alpha range in Cr-39 recorders was studied at different energy values using the over etched track profile technique. Data are discussed within the framework of track formation theory in plastic foils, comparison between experimental and theoretical values of alpha range is included

  10. The Effect of Radiator on CR-39 Registration of Fast Neutrons

    International Nuclear Information System (INIS)

    El-Badrya, B.A.; Hegazya, T.M.; Morsya, A.A.; Zaki, M.F.

    2008-01-01

    Three different configurations of a personal neutron dosimeter using CR-39 plastic detector were placed in Plastiplast pouch composed from inside to outside of Aluminum ( 27 Al, 40 Ξ m), polyethylene (PE, 20 Ξ m), Cellulose Nitrate (CN, 40 Ξ m). One dosimeter was composed of a CR-39 detector and a PE radiator (1 mm thick), another of two CR-39 detectors with one serving as radiator, and the other of CR-39 alone (without radiator). These dosimeters have been irradiated with fast neutrons of average energy 4.5 MeV with neutron fluence ranging from 5.5 x 10 6 to 0.5 x 10 8 cm - 2 emitted from 241 Am-Be neutron source. The polymeric materials have been chosen on the basis of their hydrogen contents, which are as followed: CR-39, 48%, Polyethylene, 66.7% and CN, 32% by atomic ratio to produce protons via (n, p) elastic scattering with hydrogen and increasing the detection efficiency of CR-39. After irradiation, the dose equivalent response of the detectors has been studied by using conventional etching for two periods, 6h and 8h for these configurations. The thicknesses and compositions of the radiators are chosen so as to suppress the CR-39 response below 4 MeV by preventing the recoils of hydrogen nuclei, out of the hydrogen-rich radiators (PE, CR-39), from reaching the post-etch surface of the detector. Track counting was performed using an automated system. It was found that the dosemeter responses were linear as a function of a neutron equivalent dose and that the CR-39 detector has the same response with radiator or without radiator and thus appears as a promising fast neutron dosimeter. The results are discussed and compared with the literature

  11. CR-39 plastic nuclear track detector and its application in nuclear science

    International Nuclear Information System (INIS)

    Zhai Pengji; Tang Xiaowei; Wang Long; Liang Tianjiao

    2000-01-01

    The transparent and stable plastic material CR-39 can be used as a nuclear track detector which is highly sensitive to charged particles. It can record tracks induced by protons , alphas, fission fragments and other charged particles. Among various available solid state nuclear track detectors CR-39 has the lowest deposited energy density detection-threshold. The response of CR-39 to charged particles and the response curve of υ T of different charged particles to REL are given. The CR-39 detector is widely used in studies of nuclear reactions, angular distributions and reaction cross-sections caused by neutrons and charged particles. Neutron spectra, over a wide energy range, can be measured by the combination of CR-39 and a transformation screen. The successful applications of CR-39 in alpha particle dosimetry, environmental science (especially in the measurement of radon) and in biomedicine, such as the analysis of alpha radioactivity in sections of organic tissues, are described

  12. Personnel neutron dosimetry using electrochemically etched CR-39 foils

    International Nuclear Information System (INIS)

    Hankins, D.E.; Homann, S.; Westermark, J.

    1986-01-01

    A personnel neutron dosimetry system has been developed based on the electrochemical etching of CR-39 plastic at elevated temperatures. The doses obtained using this dosimeter system are more accurate than those obtained using other dosimetry systems, especially when varied neutron spectra are encountered. This Cr-39 dosimetry system does not have the severe energy dependence that exists with albedo neutron dosimeters or the fading and reading problems encountered with NTA film. The dosimetry system employs an electrochemical etch procedure that be used to process large numbers of Cr-39 dosimeters. The etch procedure is suitable for operations where the number of personnel requires that many CR-39 dosimeters be processed. Experience shows that one full-time technician can etch and evaluate 2000 foils per month. The energy response to neutrons is fairly flat from about 80 keV to 3.5 MeV, but drops by about a factor of three in the 13 to 16 MeV range. The sensitivity of the dosimetry system is about 7 tracks/cm 2 /mrem, with a background equivalent to about 8 mrem for new CR-39 foils. The limit of sensitivity is approximately 10 mrem. The dosimeter has a significant variation in directional dependence, dropping to about 20% at 90 0 . This dosimeter has been used for personnel neutron dosimetry at the Lawrence Livermore National Laboratory for more tha 18 months. 6 refs., 23 figs., 2 tabs

  13. A dinâmica do crédito no Brasil entre 1990-2006.

    Directory of Open Access Journals (Sweden)

    Juliano Morais Galle

    2008-05-01

    Full Text Available Este artigo aborda, dentro de um contexto de globalização financeira, a dinâmica e o desenvolvimento recente do mercado financeiro e de crédito no Brasil. É mostrado que a dinâmica do crédito se caracterizou por três fases distintas entre 1990 e 2003. Além disso, discute-se que, após a implantação do Plano Real, houve um grande esforço por parte do governo brasileiro em reestruturar e reforçar o Sistema Financeiro Nacional, e que a conjuntura econômica observada atualmente no Brasil é bem mais favorável ao crescimento da relação crédito/PIB que no início da década de 2000.

  14. Measurement of indoor radon concentration by CR-39 track detector

    International Nuclear Information System (INIS)

    Yamamoto, Masayoshi; Yoneda, Shigeru; Nakanishi, Takashi.

    1990-01-01

    A convenient and cheap method for measuring indoor radon ( 222 Rn) concentration with a CR-39 track detector is described. The detector consisted of two sheets of CR-39 enclosed separately in two plastic pots : one covered by a filter (cup method) and another no covering (bare method). The bare method was used here to supplement the cup method. To compare with the result of the CR-39 detector, alpha-ray spectrometry was carried out with a Si(Au) detector in a controlled radon exposure chamber. Indoor radon concentration measured in 133 houses in several districts of Ishikawa Prefecture have been found to range from 6 Bq/m 3 to as high as 113 Bq/m 3 with a median value of 24 Bq/m 3 . The problems to measure indoor radon concentration using the CR-39 detector are also discussed with emphasis on the position of setting the detector in the room and the possible thoron contribution to the detector. (author)

  15. Calculating CR-39 Response to Radon in Water Using Monte Carlo Simulation

    International Nuclear Information System (INIS)

    Razaie Rayeni Nejad, M. R.

    2012-01-01

    CR-39 detectors are widely used for Radon and progeny measurement in the air. In this paper, using the Monte Carlo simulation, the possibility of using the CR-39 for direct measurement of Radon and progeny in water is investigated. Assuming the random position and angle of alpha particle emitted by Radon and progeny, alpha energy and angular spectrum that arrive at CR-39, the calibration factor, and the suitable depth of chemical etching of CR-39 in air and water was calculated. In this simulation, a range of data were obtained from SRIM2008 software. Calibration factor of CR-39 in water is calculated as 6.6 (kBq.d/m 3 )/(track/cm 2 ) that is corresponding with EPA standard level of Radon concentration in water (10-11 kBq/m 3 ). With replacing the skin instead of CR-39, the volume affected by Radon and progeny was determined to be 2.51 mm 3 for one m 2 of skin area. The annual dose conversion factor for Radon and progeny was calculated to be between 8.8-58.8 nSv/(Bq.h/m 3 ). Using the CR-39 for Radon measurement in water can be beneficial. The annual dose conversion factor for Radon and progeny was calculated to be between 8.8-58.8 nSv/ (Bq.h/m 3 ).

  16. Gamma dosimetry with CR-39 etch track detector

    International Nuclear Information System (INIS)

    Matiullah; Dogar, A.H.; Ahmad, N.; Amin, M.; Kudo, Katsuhisa

    1999-01-01

    To preserve and improve the safety of food for commercial purposes, it is exposed to high gamma-ray doses. The gamma-ray doses used for this purpose range from 0.15 kGy to 50 kGy. At such high doses, the etching characteristics of CR-39 are severely affected. This property, therefore, can be used to develop a CR-39-based gamma dosimeter. In this context, systematic studies were carried out and the bulk etching rate was determined as a function of gamma-ray dose using different methods. (author)

  17. Track sensitivity and the surface roughness measurements of CR-39 with atomic force microscope

    CERN Document Server

    Yasuda, N; Amemiya, K; Takahashi, H; Kyan, A; Ogura, K

    1999-01-01

    Atomic Force Microscope (AFM) has been applied to evaluate the surface roughness and the track sensitivity of CR-39 track detector. We experimentally confirmed the inverse correlation between the track sensitivity and the roughness of the detector surface after etching. The surface of CR-39 (CR-39 doped with antioxidant (HARZLAS (TD-1)) and copolymer of CR-39/NIPAAm (TNF-1)) with high sensitivity becomes rough by the etching, while the pure CR-39 (BARYOTRAK) with low sensitivity keeps its original surface clarity even for the long etching.

  18. Alpha-particle radiobiological experiments using thin CR-39 detectors

    International Nuclear Information System (INIS)

    Chan, K. F.; Siu, S. Y. M.; McClella, K. E.; Tse, A. K. W.; Lau, B. M. F.; Nikezic, D.; Richardson, B. J.; Lam, P. K. S.; Fong, W. F.; Yu, K. N.

    2006-01-01

    The present paper studied the feasibility of applying comet assay to evaluate the DNA damage in individual HeLa cervix cancer cells after alpha-particle irradiation. We prepared thin CR-39 detectors (<20 μm) as cell-culture substrates, with UV irradiation to shorten the track formation time. After irradiation of the HeLa cells by alpha particles, the tracks on the underside of the CR-39 detector were developed by chemical etching in (while floating on) a 14 N KOH solution at 37 deg. C. Comet assay was then applied. Diffusion of DNA out of the cells could be generally observed from the images of stained DNA. The alpha-particle tracks corresponding to the comets developed on the underside of the CR-39 detectors could also be observed by just changing the focal plane of the confocal microscope. (authors)

  19. Dose-equivalent response CR-39 track detector for personnel neutron dosimetry

    International Nuclear Information System (INIS)

    Oda, K.; Ito, M.; Yoneda, H.; Miyake, H.; Yamamoto, J.; Tsuruta, T.

    1991-01-01

    A dose-equivalent response detector based on CR-39 has been designed to be applied for personnel neutron dosimetry. The intrinsic detection efficiency of bare CR-39 was first evaluated from irradiation experiments with monoenergetic neutrons and theoretical calculations. In the second step, the radiator effect was investigated for the purpose of sensitization to fast neutrons. A two-layer radiator consisting of deuterized dotriacontane (C 32 D 66 ) and polyethylene (CH 2 ) was designed. Finally, we made the CR-39 detector sensitive to thermal neutrons by doping with orthocarbone (B 10 H 12 C 2 ), and also estimated the contribution of albedo neutrons. It was found that the new detector - boron-doped CR-39 with the two-layer radiator - would have a flat response with an error of about 70% in a wide energy region, ranging from thermal to 15 MeV. (orig.)

  20. Applications of CR-39 solid state nuclear track detector to ion beam diagnosis

    International Nuclear Information System (INIS)

    Kanasaki, Masato; Hattori, Atsuto; Oda, Keiji; Yamauchi, Tomoya; Fukuda, Yuji; Sakaki, Hironao; Nishiuchi, Mamiko; Kondo, Kiminori; Kurashima, Satoshi; Kamiya, Tomihiro

    2012-01-01

    CR-39 solid state nuclear track detector, which was developed for optical lens, has been applied for various field such as radon surveys, measurement of galactic cosmic ray, cell irradiation experiment and so on. The CR-39 detectors have the great advantages of being insensitive to high energy photons and electrons and capable of detecting only ions in the mixed fields such as laser driven relativistic plasmas. Though there are some analytical methods of CR-39 to diagnose ion beam, unfortunately, only few researchers in the field of plasma know the methods. This article looks at how to use CR-39 detectors and introduce the accomplishment of the joint study JAEA and Kobe Univ. for application of CR-39 detectors to ion beam diagnosis. (author)

  1. Calculation of thermal effects occurring during the manufacture of CR-39 sheets

    Energy Technology Data Exchange (ETDEWEB)

    Szilagyi, S.; Somogyi, G. (Magyar Tudomanyos Akademia, Debrecen. Atommag Kutato Intezete)

    1984-01-01

    To manufacture a good-quality, uniform CR-39 track detector, the polymerization rate should be chosen below a critical value to avoid the development of undesirable thermal gradients and internal temperature fluctuations in the sheet being cast. To improve curing cycles, especially for thick CR-39 sheets, a computer programme was developed by which we could study the trends of thermal effects under different casting conditions. Our calculations are based on the solution of the one dimensional heat transport equation, taking into account the relations proposed by Dial et al (1955) for describing the chemical kinetics of CR-39 polymerization. We have revised the empirical parameters available to such calculations. With new 'Dial constants' we have calculated the critical initial bath temperature (which results in thermal runaway at the central plane of the sheet being cast) as a function of the CR-39 thickness and IPP initiator concentration. Results are also presented for the temperature profile developing in the depth of cast CR-39 sheets.

  2. Calculation of thermal effects occurring during the manufacture of CR-39 sheets

    International Nuclear Information System (INIS)

    Szilagyi, S.; Somogyi, G.

    1984-01-01

    To manufacture a good-quality, uniform CR-39 track detector, the polymerization rate should be chosen below a critical value to avoid the development of undesirable thermal gradients and internal temperature fluctuations in the sheet being cast. To improve curing cycles, especially for thick CR-39 sheets, a computer programme was developed by which we could study the trends of thermal effects under different casting conditions. Our calculations are based on the solution of the one dimensional heat transport equation, taking into account the relations proposed by Dial et al (1955) for describing the chemical kinetics of CR-39 polymerization. We have revised the empirical parameters available to such calculations. With new 'Dial constants' we have calculated the critical initial bath temperature (which results in thermal runaway at the central plane of the sheet being cast) as a function of the CR-39 thickness and IPP initiator concentration. Results are also presented for the temperature profile developing in the depth of cast CR-39 sheets. (author)

  3. The response of CR-39 nuclear track detector to 1-9 MeV protons

    International Nuclear Information System (INIS)

    Sinenian, N.; Rosenberg, M. J.; Manuel, M.; McDuffee, S. C.; Casey, D. T.; Zylstra, A. B.; Rinderknecht, H. G.; Gatu Johnson, M.; Seguin, F. H.; Frenje, J. A.; Li, C. K.; Petrasso, R. D.

    2011-01-01

    The response of CR-39 nuclear track detector (TasTrak) to protons in the energy range of 0.92-9.28 MeV has been studied. Previous studies of the CR-39 response to protons have been extended by examining the piece-to-piece variability in addition to the effects of etch time and etchant temperature; it is shown that the shape of the CR-39 response curve to protons can vary from piece-to-piece. Effects due to the age of CR-39 have also been studied using 5.5 MeV alpha particles over a 5-year period. Track diameters were found to degrade with the age of the CR-39 itself rather than the age of the tracks, consistent with previous studies utilizing different CR-39 over shorter time periods.

  4. Neutron detection using CR-39 and Atomic Force Microscopy (AFM)

    International Nuclear Information System (INIS)

    Vazquez L, C.; Fragoso, R.; Felix, R.; Golzarri, J.I.; Espinosa, G.; Castillo, F.

    2007-01-01

    AFM has been applied in many CR-39 track formation analyses. In this paper, the use of AFM in the neutron detection and analysis of the track formation is reported. The irradiation was made with an 1.5 GBq (0.5 Ci) 241 Am-Be neutron source, with and without a polyethylene radiator. The surface analysis was made to the CR-39 fresh material without irradiation, after the irradiation, and after a very short etching time. The results show important differences between the irradiation, with and without polyethylene radiator, and the latent tracks of the neutron in the CR-39 polycarbonate. The development of track formation after very short etching time and pits characterization were measured too using the AFM facilities. (Author)

  5. Detection of light charged particles from plasma focus by CR-39

    Energy Technology Data Exchange (ETDEWEB)

    Antanasijevic, R.; Vukovic, J.; Popovic, S.; Popovic, M. (Belgrade Univ. (Yugoslavia). Inst. za Fiziku); Puric, J.; Cuk, M. (Faculty of Physical Science, Belgrade (Yugoslavia))

    1991-01-01

    An analysis of a deuteron (D{sup +}) beam, emitted from a plasma focus has been carried out, using a CR-39 plastic nuclear track detector. The CR-39 was pretreated using different processes to destroy the existing background before exposing it to the particles produced in the plasma focus. From measurements of the diameters of the tracks, the estimated energy of the D{sup +} ions is about 0.5 MeV. The total number of emitted D{sup +} ions was 10 particles/pulse. Some preliminary results on imaging etched CR-39 with an Atomic Force Microscope (NanoScope AFM) are also presented. (author).

  6. Detection of light charged particles from plasma focus by CR-39

    International Nuclear Information System (INIS)

    Antanasijevic, R.; Vukovic, J.; Popovic, S.; Popovic, M.

    1991-01-01

    An analysis of a deuteron (D + ) beam, emitted from a plasma focus has been carried out, using a CR-39 plastic nuclear track detector. The CR-39 was pretreated using different processes to destroy the existing background before exposing it to the particles produced in the plasma focus. From measurements of the diameters of the tracks, the estimated energy of the D + ions is about 0.5 MeV. The total number of emitted D + ions was 10 particles/pulse. Some preliminary results on imaging etched CR-39 with an Atomic Force Microscope (NanoScope AFM) are also presented. (author)

  7. gamma-induced modification on optical band gap of CR-39 SSNTD

    International Nuclear Information System (INIS)

    Zaki, M.F.

    2010-01-01

    effect of gamma irradiation on optical absorption of nuclear track detectors like CR-39 was studied at different absorbed doses using ultraviolet-visible (UV-VIS)spectroscopy. the existence of the peaks, their shifting and broadening as a result of gamma irradiation has been discussed. the width of the tail of localized states in the band gap (E u )was evaluated using the Urbach edge method. finally the indirect and direct band gap in pristine and gamma irradiated CR-39 have been determined. the values of indirect band gap have been found to be lower than the corresponding values of direct band gap. a decrease in the optical energy gap with increasing the gamma absorbed dose can be discussed on the basis of gamma-irradiation-induced defects in the CR-39. the correlation between optical band gap and the number of carbon atoms in a cluster with modified Tauc's equation has been discussed in case of CR-39.

  8. Development of neutron dosimeter using CR-39 for measurement of ambient dose equivalent

    International Nuclear Information System (INIS)

    Maki, Daisuke; Shinozaki, Wakako; Ohguchi, Hiroyuki; Yamamoto, Takayoshi; Nakamura, Takayoshi

    2010-01-01

    A CR-39 has good advantages such as cumulative type dosimeter, small fading effect and gamma-ray insensitive. Therefore, we developed the wide energy-range environmental neutron dosimeter using eight CR-39s for area monitoring in this study. This dosimeter is made of octagonal columnar polyethylene block which height is 60 mm and bottom side is 25 mm. The dosimeter contains two types of CR-39s for fast neutron detection and slow neutron detection. Four CR-39s for fast neutron detection are used for detection of recoil protons produced by H (n, p) reactions. Four CR-39s for slow neutron detection are used with boron nitride converter to detect alpha-rays produced by 10 B (n, α) 7 Li reactions. Ambient dose equivalent is obtained by adding the number of etch-pits observed in four CR-39s for fast neutron detection to the number of etch-pits observed in four CR-39s for slow neutron detection with appropriate constants respectively. Dosimeters were irradiated with some energetic neutrons and evaluated results of ambient dose equivalent were compared with results from neutron transport calculations. Energy response of dosimeter shows good agreement with neutron fluence to ambient dose equivalent conversion coefficients. Directional dependence of dosimeter is at the same level as the rem-counter. (author)

  9. Development of neutron personnel monitoring system based on CR-39 solid state nuclear track detector

    International Nuclear Information System (INIS)

    Massand, O.P.; Kundu, H.K.; Marathe, P.K.; Supe, S.J.

    1990-01-01

    Personnel neutron monitoring aims at providing a method to evaluate the magnitude of the detrimental effects on the personnel exposed to neutrons. Neutron monitoring is done for a small though growing number of personnel working with neutrons in a wide range of situations. Over the years, many solid state nuclear track detectors (SSNTD) have been tried for neutron personnel monitoring. CR-39 SSNTD is a proton sensitive polymer and offers a lot of promise for neutron personnel monitoring due to its high sensitivity and lower energy threshold for neutron detection. This report presents the mechanism of track formation in this polymer, the development of this neutron personnel monitoring system in our laboratory, its various characteristics and its promise as a routine personnel neutron monitor. (author). 1 tab., 7 figs

  10. Simple preparation of thin CR-39 detectors for alpha-particle radiobiological experiments

    International Nuclear Information System (INIS)

    Chan, K.F.; Lau, B.M.F.; Nikezic, D.; Tse, A.K.W.; Fong, W.F.; Yu, K.N.

    2007-01-01

    Alpha-particle radiobiological experiments involve irradiating cells with alpha particles and require accurate positions where the alpha particles hit the cells. In the present work, we prepared thin CR-39 detectors from commercially available CR-39 SSNTDs with a thickness of 100 μm by etching them in 1 N NaOH/ethanol at 40 deg. C to below 20 μm. The desired final thickness was achieved within ∼8 h. Such etching conditions can provide relatively small roughness of the detector as revealed by atomic force microscope, and thus provide transparent detectors for radiobiological experiments. UV radiation was employed to shorten track formation time on these thin CR-39 detectors. After exposure to UV light (UVA + B radiation) for 2-3 h with doses from 259 to 389 W/cm 2 , 5 MeV alpha-particle tracks can be seen to develop on these CR-39 detectors clearly under the optical microscope within 2 h in 14 N KOH at 37 deg. C. As an example for practical use, custom-made petri dishes, with a hole drilled at the bottom and covered with a thin CR-39 detector, were used for culturing HeLa cells. The feasibility of using these thin CR-39 detectors is demonstrated by taking photographs of the cells and alpha-particle tracks together under the optical microscope, which can allow the hit positions on the cells by the alpha particles to be determined accurately

  11. Polymerization, structure and track recording properties of CR-39 cured with UV photoinitiators

    International Nuclear Information System (INIS)

    Stejny, J.; Carrell, J.; Palmer, M.J.

    2000-01-01

    CR-39 monomer was cured isothermally at temperatures from 54.5 to 115 deg. C with UV sensitive photoinitiators to high conversions. The use of photoinitiators allowed the cure of CR-39 isothermally at high temperatures and eliminated the danger of thermal runaway present in the conventionally used thermal initiation with peroxides. It was found that the properties of the UV photoinitiated CR-39 were similar to the conventionally polymerized resin

  12. Studies on nitrogen mapping by various CR-39 track detectors

    Energy Technology Data Exchange (ETDEWEB)

    Somogyi, G.; Varga, Zs.; Hunyadi, I.; Freyer, K.; Treutler, H.Ch.

    1986-01-01

    The use of CR-39 track detectors for nitrogen distribution measurements via the /sup 14/N(n,p)/sup 14/C reaction is studied. The proton detection properties of different CR-39 products have been analyzed. The variation of background track density induced in the bulk of detectors is examined under different conditions of neutron irradiation. Analysis of our experimental data has led to the conclusion that the sources of proton background tracks are the fast neutron component of the neutron source, chlorine impurities in the detector and nitrogen diffused from the air into the upper layer of the detector. Efforts have been made to decrease the nitrogen content of diffusion origin by removing the upper detector layer and by outgassing the CR-39 sheet in vacuum before irradiation. Finally the ''signal/noise'' ratio for a steel specimen and the sensitivity of nitrogen determination are given.

  13. Registration properties of different types of CR-39 in vacuum conditions of irradiation

    International Nuclear Information System (INIS)

    Golovchenko, A.N.; Tret'yakova, S.P.

    1991-01-01

    Sensitivity change has been studied of different types of CR-39 detectors (Pershore, Tastrak, Intercast, Ma-ND/α) in dependence on holding time of detector in vacuum chamber at the residual pressure P ≅ 2x10 -2 and ≅ 5x10 -3 Pa before their irradiation with alpha particles from thin 238 Pu source and accelerated charged ions with atomic number Z=2-10 and energy of 9.1 MeV/nucleon. Polymer of Intercast Company turned out to be the most stable one to vacuum effect, and detector does not change the sensitivity up to response function REL 200 ≅ 1 MeVxcm 2 xmg -1 in the mentioned experiment conditions. 7 refs.; 3 figs

  14. Alpha-particle response characteristics of CR-39

    International Nuclear Information System (INIS)

    Abou El-Khier, A.A.; Gaber, M.; El-Khatib, A.M.; Fawzy, M.A.

    1987-01-01

    The form of the response curve of the polycarbonate CR-39 for α-particles at relatively low energies has been established. The investigation included measurements of both bulk- and track-etch rates. The latter was measured as a function of α-particle energies. (author)

  15. A CR-39 track dosemeter for routine individual neutron monitoring

    International Nuclear Information System (INIS)

    Luszik-Bhadra, M.; Alberts, W.G.; Dietz, E.; Guldbakke, S.; Matzke, M.; d'Errico, F.

    1994-01-01

    A personal neutron dosemeter for routine individual monitoring is proposed. It is based on a CR-39 track detector covered on three separate areas by converters with different boron contents and inserted into a commercial TLD albedo dosemeter capsule. The dose readings from three areas of the electrochemically etched CR-39 detector are combined to yield a dose equivalent response which is almost independent of the incident neutron energy in the range from thermal neutrons up to 20 MeV. In addition, the dose contributions of thermal, intermediate and fast neutrons can be determined separately. Unlike the TLD albedo dosemeter, which in general requires prior in-field calibration and whose use is then restricted to that field, this dosemeter can be used in neutron fields without any knowledge of the spectral distribution with the same calibration factor. The angular dependence of the dosemeter's response has been measured and compared with that of the directional dose equivalent H'(10). The lower limit of detection is 0.15 mSv. It is possible to obtain an independent, second dose reading from the same Cr-39 detector for neutron energies above 100 keV. The dosemeter has also been successfully tested for use in accident dosimetry applying chemical etching and an optical density reading of the CR-39 detector. (author)

  16. Calculation of thermal effects occuring during the manufacture of CR-39 sheets

    Energy Technology Data Exchange (ETDEWEB)

    Szilagyi, S.; Somogyi, G.

    1984-01-01

    To manufacture a good-quality, uniform CR-39 track detector, the polymerization rate should be below a critical value to avoid the development of undesirable thermal gradients and internal temperature fluctuations in the sheet being cast. To improve curing cycles a computer program was developed to study the trends of thermal effects under different casting conditions. These calculations are based on the solution of the one-dimensional heat transport equation and take into account the relations proposed by Dial et. al. for describing the chemical kinetics of CR-39 polymerization. The authors have revised the empirical parameters available to such calculations. With new ''Dial constants'' they have calculated the critical initial bath temperature (which results in thermal runaway at the central plane of the sheet being cast) as a function of the CR-39 thickness and IPP initiator concentration. Results are also presented for the temperature profile in the depth of cast CR-39 sheets.

  17. Note: Fast neutron efficiency in CR-39 nuclear track detectors

    Energy Technology Data Exchange (ETDEWEB)

    Cavallaro, S. [Dipartimento di Fisica ed Astronomia,Università di Catania, Via S. Sofia 44, 95123 Catania, Italy and INFN-LNS, Via S. Sofia 42, 95123 Catania (Italy)

    2015-03-15

    CR-39 samples are commonly employed for fast neutron detection in fusion reactors and in inertial confinement fusion experiments. The literature reported efficiencies are strongly depending on experimental conditions and, in some cases, highly dispersed. The present note analyses the dependence of efficiency as a function of various parameters and experimental conditions in both the radiator-assisted and the stand-alone CR-39 configurations. Comparisons of literature experimental data with Monte Carlo calculations and optimized efficiency values are shown and discussed.

  18. Cutting thin sheets of allyl diglycol carbonate (CR-39) with a CW CO2, laser

    International Nuclear Information System (INIS)

    Kukreja, L.M.; Bhawalkar, D.D.; Basu, C.; Goswami, J.N.

    1984-01-01

    Recent studies have shown that Allyl Diglycol Carbonate, commercially known as CR-39 (the most sensitive among etch track detectors) can detect relativistic oxygen and other heavier nuclei. We are using large sheets of special grade CR-39 (DOP) in our experiment in Space Shuttle-Spacelab-3. As CR-39 is a highly brittle substance, special care is required to cut CR-39 shetts, especially in case of large sheets and circular cuts. A study of cutting of CR-39 sheets using laser light is described in this paper. It has been found that this method is sufficiently fast to handle large number of sheets and also equally safe for big sheets. A maximum speed up to 200 cm/min with a 5 x 10 4 W/cm 2 laser is obtained during the present study. This study also shows that laser cutting does not affect the track properties of CR-39. (orig.)

  19. Development of hybrid track detector using CR39 and photographic plate

    International Nuclear Information System (INIS)

    Kuge, Kenichi; Endo, Yusuke; Hayashi, Kentaro; Hasegawa, Akira; Kumagai, Hiroshi

    2004-01-01

    Hybrid track detector using CR39 and color photography was prepared by coating multi-layered color photographic emulsions on one side of CR39. Etch pits and color tracks were observed at the same time. Photographic plate with different sensitivity emulsions and couplers were exposed to light, α-, β- and γ-rays. We observed sensitivity difference to the radiation by color changes on one plate. (authors)

  20. Proton an alpha detections by track recording technique in CR-39

    International Nuclear Information System (INIS)

    Oliveira, W.A. de; Franco, M.A.R.; Herdade, S.B.; Khouri, M.C.F.; Goncalez, O.L.

    1986-07-01

    The plastic CR-39 is utilized as proton track detector in the study of the reaction 27 A (e, p) and 59 Co (e, p), near threshold. Preliminary results are presented for the energy calibration (mean track diameter as a function of proton energy) of CR-39 with mono-energetic protons of a Van de Graaff accelerator, in the energy range 1-3 MeV. (author) [pt

  1. Effect of radiation on the electrical properties of plastic detector CR-39

    International Nuclear Information System (INIS)

    Mahmoud, S.A.; Hamed, A.E.; Abou El-Kier, A.A.; Mousse, M.G.; Kassem, M.E.; El-Shafey, E.M.

    1994-01-01

    The effect of high alpha-particle fluence on plastic detector CR-39 was studied by measuring the electrical properties of the detector as a function of irradiation dose and frequency using an impedance meter in the frequency range 0.005-500 kHz. When the plastic detector CR-39 is exposed to high irradiation doses, it loses its advantage as a track detector, because of the overlapping of the tracks occurring in the detector at high irradiation fluence. Through the present measurements of dielectric permittivity and conductivity at different frequencies and temperatures, CR-39 could be used as a dosimeter for high irradiation doses

  2. Effect of radiation on the electrical properties of plastic detector CR-39

    Energy Technology Data Exchange (ETDEWEB)

    Mahmoud, S.A.; Hamed, A.E.; Abou El-Kier, A.A.; Mousse, M.G.; Kassem, M.E.; El-Shafey, E.M. (Physics Department Faculty of Science, Alexandria University, Alexandria (Egypt))

    1994-10-15

    The effect of high alpha-particle fluence on plastic detector CR-39 was studied by measuring the electrical properties of the detector as a function of irradiation dose and frequency using an impedance meter in the frequency range 0.005-500 kHz. When the plastic detector CR-39 is exposed to high irradiation doses, it loses its advantage as a track detector, because of the overlapping of the tracks occurring in the detector at high irradiation fluence. Through the present measurements of dielectric permittivity and conductivity at different frequencies and temperatures, CR-39 could be used as a dosimeter for high irradiation doses.

  3. Fast neutron irradiation effects on CR-39 nuclear track detector for dosimetric applications

    International Nuclear Information System (INIS)

    Kader, M.H.

    2005-01-01

    The effect of neutron irradiation on the dosimetric properties of CR-39 solid-state nuclear track detector have been investigated. CR-39 samples were irradiated with neutrons of energies follow a Maxwellian distribution centered about 2 MeV. These samples were irradiated with different doses in the range 0.1-1 Sv. The background and track density were measured as a function of etching time. In addition, the dependence of sensitivity of CR-39 detector on the neutrons dose has been investigated. The results show that the Sensitivity started to increase at 0.4 Sv neutrons dose, so this sample were chosen to be a subject for further study to investigate the effect of gamma dose on its properties. The sample irradiated with 0.4 Sv were exposed to different doses of gamma rays at levels between 10 and 80 kGy. The effect of gamma doses on the bulk etching rate VB, the track diameter and the sensitivity of the CR-39 samples was investigated. The results show that the dosimetric properties of CR-39 SSNTD are greatly affected by both neutron and gamma irradiation

  4. LET spectrum measurements in Cr-39 PNTD with AFM

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Carl Edward [Los Alamos National Laboratory; De Witt, Joel M [OSU, PHYSICS; Benton, Eric R [OSU, PHYSICS; Yasuda, Nakahiro [NIRS, HIMAC; Benton, Eugene V [UNIV OF SAN FRANCISCO

    2010-01-01

    Energetic protons, neutrons, and heavy ions undergoing collisions with target nuclei of varying Z can produce residual heavy recoil fragments via intra-nuclear cascade/evaporation reactions. The particles produced in these non-elastic collisions generally have such extremely short range ({approx}< 10 {mu}m) that they cannot be directly observed by conventional detection methods including CR-39 plastic nuclear track detector (PNTD) that has been chemically etched for analysis by standard visible light microscopy. However, high-LET recoil fragments having range on the order of several cell diameters can be produced in tissue during radiotherapy using proton and carbon beams. We have developed a method to analyze short-range, high-LET tracks in CR-39 plastic nuclear track detector (PNTD) using short duration chemical etching ({approx}< 1 {mu}m) followed by automated atomic force microscope (AFM) scanning. The post-scan data processing used in this work was based on semi-automated matrix analysis opposed to traditional grey-scale image analysis. This method takes advantage of the 3-D data obtained via AFM to achieve robust discrimination of nuclear tracks from other features. Through automation of AFM scanning, sufficient AFM scan frames were obtained to attain an LET spectrum spanning the LET range from 200-1500 keV/{mu}m. In addition to our experiments, simulations were carried out with the Monte Carlo transport code, FLUKA. To demonstrate this method, CR-39 PNTD was exposed to the proton therapy beam at Loma Linda University Medical Center (LLUMC) at 60 and 230 MeV. Additionally, detectors were exposed to I GeV protons at the NASA Space Radiation Laboratory (NSRL) at Brookhaven National Laboratory (BNL). For these exposures CR-39 PNTD, Al and Cu target foils were used between detector layers.

  5. LET spectrum measurements in Cr-39 PNTD with AFM

    International Nuclear Information System (INIS)

    Johnson, Carl Edward; DeWitt, Joel M.; Benton, Eric R.; Yasuda, Nakahiro; Benton, Eugene V.

    2010-01-01

    Energetic protons, neutrons, and heavy ions undergoing collisions with target nuclei of varying Z can produce residual heavy recoil fragments via intra-nuclear cascade/evaporation reactions. The particles produced in these non-elastic collisions generally have such extremely short range (∼< 10 μm) that they cannot be directly observed by conventional detection methods including CR-39 plastic nuclear track detector (PNTD) that has been chemically etched for analysis by standard visible light microscopy. However, high-LET recoil fragments having range on the order of several cell diameters can be produced in tissue during radiotherapy using proton and carbon beams. We have developed a method to analyze short-range, high-LET tracks in CR-39 plastic nuclear track detector (PNTD) using short duration chemical etching (∼< 1 μm) followed by automated atomic force microscope (AFM) scanning. The post-scan data processing used in this work was based on semi-automated matrix analysis opposed to traditional grey-scale image analysis. This method takes advantage of the 3-D data obtained via AFM to achieve robust discrimination of nuclear tracks from other features. Through automation of AFM scanning, sufficient AFM scan frames were obtained to attain an LET spectrum spanning the LET range from 200-1500 keV/μm. In addition to our experiments, simulations were carried out with the Monte Carlo transport code, FLUKA. To demonstrate this method, CR-39 PNTD was exposed to the proton therapy beam at Loma Linda University Medical Center (LLUMC) at 60 and 230 MeV. Additionally, detectors were exposed to I GeV protons at the NASA Space Radiation Laboratory (NSRL) at Brookhaven National Laboratory (BNL). For these exposures CR-39 PNTD, Al and Cu target foils were used between detector layers.

  6. Effect of Gamma Rays on Fast Neutron Registration in CR-39

    CERN Document Server

    Kobzev, A P; El-Halem, A A; Abdul-Ghaphar, U S; Salama, T A

    2002-01-01

    A set of CR-39 plastic detectors with front PE radiator was exposed to Am-Be neutron source, which has an emission rate of 0.86\\cdot 10^{7} sec^{-1}, and the neutron dose equivalent rate 1 m apart from the source is equal to 11 mrem/hr. Another set of samples was irradiated by a neutron dose of 4 rem, then exposed to different gamma-ray doses using ^{60}Co source. It was found that the track density grows with the increase of neutron dose and etching time. It was also found that the bulk etching rate V_{B}, the track diameter and the sensitivity of the CR-39 plastic detector with respect to the neutron irradiation increased with increasing gamma-ray dose in the range 1?10 Mrad. These results show that CR-39 can be considered as a promising fast neutron dosimeter and gamma-ray dosimeter.

  7. Sensitivity determination of CR-39 from Normal and inclined incidence

    International Nuclear Information System (INIS)

    Abou, A.A.; El-Kheir, A.A.; Daas, A.F.; Awwad, Z.; Reda, A.M.

    2000-01-01

    An experimental study have been carried out on alpha- particle track opening (Major and minor axes) using alpha-particles of different energies incident with different angels in addition to the normal incidence. The sensitivity of CR-39 in present work is determined for each of normal and inclined incidence. The results indicated a difference in the sensitivity according to angle of incidence. The variation of alpha- particle tracks (major and minor axes) are calculated and compared with our measured values. Also, it is found that the sensitivity of CR-39 detector is change due to the storage time at room temperature

  8. Calibration of CR-39 for radon-related parameters using sealed cup technique

    International Nuclear Information System (INIS)

    Abo-Elmagd, M.; Daif, M. M.

    2010-01-01

    Effective radium content, mass and areal radon exhalation rates of soil and rock samples are important radon-related parameters and can be used as a better indicator of radon risk. A sealed cup fitted to a CR-39 detector and to the sample under measurement is an advantageous passive device for the measurement of these parameters. The main factors affecting the results are the detector calibration factor and the sample weight. The results of an active technique (Lucas cell) and the CR-39 detector have been found to be correlated resulting in a reliable detector calibration factor. The result illustrates the dependence of the CR-39 calibration factor with the sample weight which is difficult to use in practice, because each sample weight has its own calibration factor of CR-39. It is reported to demonstrate the advantage of a back diffusion correction. After correcting the results for back diffusion effects, one obtains an approximately constant calibration factor for the sample volumes up to one-third the total sealed cup volume. For this condition the calibration factor is equal to 0.237 track cm -2 per Bq m -3 d with about 1% uncertainty. (authors)

  9. Range energy for heavy ions in CR-39

    International Nuclear Information System (INIS)

    Gil, L.R.; Marques, A.

    1987-01-01

    Range-energy relations in CR-39, for ions from He to Ar, are obtained after their effective nuclear charge. Comparison with earlier calculations and numerical results in the energy range 0,1 to 200 Mev/ Nucleon are also given. (M.W.O.)

  10. Thermal studies on unirradiated and γ-irradiated polymer of allyl diglycol carbonate

    International Nuclear Information System (INIS)

    Kalsi, P.C.; Pandey, A.K.; Iyer, R.H.; Singh Mudher, K.D.

    1995-01-01

    The thermal decomposition of unirradiated and γ-irradiated (5.93-15.5 MRad dose range) allyl diglycol carbonate polymer (trade name, CR-39) was studied by thermogravimetry (TG) and differential thermal analysis (DTA). These studies indicate four main decomposition steps in CR-39 polymer in air. Assessment of the influence of radiation dose on the above range shows that while the 5.93 MRad γ-irradiated polymer CR-39 degrades in three steps, the 15.5 MRad γ-irradiated polymer degrades in only two steps. The kinetics of the different stages of degradation were also evaluated from the TG curves. Irradiation enhances the decomposition rate and the effect increases further with increasing radiation dose. The activation energy values calculated for all the decomposition stages decrease on irradiation

  11. CR-39 nuclear track detector used for neutron dosimetry: system calibration

    International Nuclear Information System (INIS)

    Saint Martin, G.; Lopez, F.; Bernaola, Omar A.

    2009-01-01

    Stacks composed by 1 mm thickness CR-39 foils and polyethylene and PVC films were evaluated to be used as neutron dosemeters. Irradiations were made with a calibrated 241 Am-Be source in a dose range from 0 to 3.1 mSv and the etching conditions were optimized. The measurements of number of tracks per surface unit in the CR-39 detectors showed a good linear behaviour as a function of the dose. The minimum detectable dose equivalent (MDDE) was calculated. (author)

  12. The effects of retrograde reactions and of diffusion on 39Ar-40Ar ages of micas

    DEFF Research Database (Denmark)

    Allaz, Julien; Engi, Martin; Berger, Alfons

    2011-01-01

    Effects of metamorphic reactions occurring during decompression were explored to understand their influence on 39Ar-40Ar ages of micas. Monometamorphic metasediments from the Lepontine Alps (Switzerland) were studied. Collected samples reached lower amphibolite facies during the Barrovian....... XRD-data indicated that some mineral separates prepared for Ar-Ar stepwise heating analysis were monomineralic, whereas others were composed of two white micas (muscovite with paragonite or margarite), or biotite and chlorite. In monomineralic samples 37Ar/39Ar and 38Ar/39Ar (proportional to Ca....../K and Cl/K ratios) did not change and the resulting ages can be interpreted unambiguously. In mineral separates containing two white micas, Ca/K and Cl/K ratios were variable, reflecting non-simultaneous laboratory degassing of the two heterochemical Ar-reservoirs. These ratios were used to identify each...

  13. Optical, structural, and chemical properties of CR-39 implanted with 5.2 MeV doubly charged carbon ions

    Science.gov (United States)

    Ali, Dilawar; Butt, M. Z.; Ishtiaq, Mohsin; Waqas Khaliq, M.; Bashir, Farooq

    2016-11-01

    Poly-allyl-diglycol-carbonate (CR-39) specimens were irradiated with 5.2 MeV doubly charged carbon ions using Pelletron accelerator. Ion dose was varied from 5 × 1013 to 5 × 1015 ions cm-2. Optical, structural, and chemical properties were investigated by UV-vis spectroscopy, x-ray diffractometer, and FTIR/Raman spectroscopy, respectively. It was found that optical absorption increases with increasing ion dose. Absorption edge shifts from UV region to visible region. The measured opacity values of pristine and ion implanted CR-39 range from 0.0519 to 4.7959 mm-1 following an exponential growth (9141%) with the increase in ion dose. The values of direct and indirect band gap energy decrease exponentially with an increase in ion dose by 59% and 71%, respectively. However, average refractive index in the visible region increases from 1.443 to 2.864 with an increase in ion dose, by 98%. A linear relation between band gap energy and crystallite size was observed. Both the number of carbon atoms in conjugation length and the number of carbon atoms per cluster increase linearly with the increase in ion dose. FTIR spectra showed that on C+2 ions irradiation, the intensity of all bands decreases gradually without appearance of any new band, indicating degradation of polymer after irradiation. Raman spectra revealed that the density of -CH2- group decreases on C+2 ions irradiation. However, the structure of CR-39 is completely destroyed on irradiation with ion dose 1 × 1015 and 5 × 1015 ions cm-2.

  14. Effects of additives and impurities on the properties of CR-39 neutron dosimeters

    International Nuclear Information System (INIS)

    Tarle, G.

    1982-01-01

    Several problems have plagued users of commercial CR-39 for neutron dosimetry work. Large variations in sensitivity have been observed in samples received from different manufacturers, from different batches from the same manufacturer and even within a given sheet. The latter variations have taken several forms. Clear etching regions of lower sensitivity near the gasket and sometimes extending well away from the gasket in drip-like patterns have been observed. Large demarcated patches of differing sensitivity and sensitivity variations with depth have been found in many commercial samples of CR-39. In addition, we have observed a general roughening of the post-etch surface and a patchiness of bulk etching associated with contact patterns of adjacent sheets, which have been stored for extended (greater than or equal to 6 mos) periods of time. All of these problems combine to make commercially available CR-39 unreliable as a neutron dosimeter. In an attempt to identify and correct the causes of these problems, a systematic study of the effects of additives, impurities and manufacturing conditions on the uniformity of CR-39 track detectors has been undertaken, and is reported in this paper

  15. Use of CR-39 foils for personnel neutron dosimetry: improved electrochemical etching chambers and procedures

    International Nuclear Information System (INIS)

    Hankins, D.E.; Homann, S.G.; Westermark, J.

    1986-01-01

    The electrochemical etching procedures for the new dosimetry system that uses foils of CR-39 plastic has been improved. During 1985, the etching chambers were modified to correct several problems and the changes to the etching procedures were studied, which gave a more uniform track density and size. The currently recommended etch parameters are given. A new generation of CR-39 material from the manufacturer proved to have a considerably lower background track density and a higher sensitivity; the new foils are also more uniform in thickness, which eliminates the need to numerically compensate for thickness variations. The energy dependence of the CR-39 using monoenergetic neutrons from accelerators at Battelle Northwest Laboratories and at Los Alamos National Laboratory was determined. Some variation was found in the energy dependence, but it is believed this was caused by changes in the etching procedures and by uncertainties in the fluences of the neutrons from the accelerators. A means by which the counting of CR-39 tracks may be automated is suggested; this would be very useful in adapting the CR-39 dosimetry system to large-scale use

  16. Application of CR-39 to radon measurement

    International Nuclear Information System (INIS)

    Miyake, Hiroshi

    1988-01-01

    CR-39, an ally diglycol carbonate, has recently come into wider use as material for solid-state track detector. Etching with NaOH or KOH solution allow CR-39 to develop extremely clear etch pits attributed to alpha rays. The most widely used method for measuring radon concentration employs a plastic cup with a solid-state track detector mounted at its bottom to detect alpha rays resulting from radon or its daughters that disintegrate within or on the wall of the cup. Simple in mechanism and low in cost, this method is suitable for such a case where the radon concentration distribution over a wide area has to be measured by using a large number of devices. The concentration of radon alone can be measured with the aid of a filter attached to the mouth of the cup to remove the daughters of radon and thoron. The simplest and most effective way of improving the sensitivity of a solid-state track detector for radon concentration measurement is to electrostatically collect daughters resulting from decay of radon onto the surface of the detector. Another method widely used to determine the radon concentration is to measure the concentration of the radon daughters instead of direct measurement of the concentration of radon itself. (Nogami, K.)

  17. Fast neutron dosimetry using CR-39 track detectors with polyethylene as radiator

    International Nuclear Information System (INIS)

    Castillo, F.; Espinosa, G.; Golzarri, J.I.; Osorio, D.; Rangel, J.; Reyes, P.G.; Herrera, J.J.E.

    2013-01-01

    The chemical etching parameters (etching time, temperature, normality of etchant, etc.) for the use of CR-39 (allyl diglycol carbonate – Lantrack ® ) as a fast neutron dosimeter have been optimized. The CR-39 chips, placed under a 1.5 mm polyethylene radiator, were exposed for calibration to an 241 Am-Be source at different time intervals for a given neutron fluence. After several chemical etching processes of the detectors with different conditions, the optimum characteristics for the chemical etching were found at 6N KOH solution, 60 ± 1 °C, for 12 h. An accurate relationship between the dose and fluence calculations was obtained as a function of the track density. - Highlights: ► Optimum etching time for fast neutron irradiated CR-39 track detectors is found. ► Relationship between dose and fluence obtained as a function of the track density. ► Results are consistent with those reported elsewhere, and extend the dose range

  18. The Use Of Optical Properties Of Cr-39 In Alpha Particle Equivalent Dose Measurements

    International Nuclear Information System (INIS)

    Shnishin, K.A.

    2007-01-01

    In this work, optical properties of alpha irradiated Cr-39 were measured as a function of optical photon wavelength from 200-1100 nm. Optical energy gap and optical absorption at finite wavelength was also calculated and correlated to alpha fluence and dose equivalent. Alpha doses were calculated from the corresponding irradiation fluence and specific energy loss using TRIM computer program. It was found that, the optical absorption of unattached Cr-39 was varied with alpha fluence and corresponding equivalent doses. Also the optical energy gab was varied with fluence and dose equivalent of alpha particles. This work introduces a reasonably simple method for the Rn dose equivalent calculation by Cr-39 track

  19. Track etch parameters and annealing kinetics assessment of protons of low energy in CR-39 detector

    International Nuclear Information System (INIS)

    Jain, R.K.; Kumar, Ashok; Singh, B.K.

    2012-01-01

    Highlights: ► We calibrate CR-39 detector with very low energy protons. ► We establish linear relationship between track diameter and time/energy up to 200 keV. ► We determine activation energy of annealing using different models. ► We justify concept of single annealing activation energy in CR-39. - Abstract: In this paper threshold of the registration sensitivity of very low energy proton in CR-39 is investigated. Irradiation of CR-39 (poly-allyl-diglycol carbonate) was carried out with very low energy mono energetic protons of 20–60 keV from a mini proton accelerator. Nearly 10 4 /cm 2 fluence of protons was used. The variation of track diameter with etching time as well as proton energy response curve was carefully calibrated. The bulk and track etch rates were measured by using proton track diameters. Bulk etch rate was also measured by the thickness of removed surface layer. The thermal annealing of proton track at temperatures ranging from 100 to 200 °C in CR-39 was studied by several models. Activation energy of annealed CR-39 detectors was calculated by slope of track etch rate and temperature plot. The data of proton tracks of 200, 250 and 300 keV from 400 kV Van-de-Graaff accelerator was also used and compared with the track diameters of different energies of proton.

  20. Impact of x-ray dose on the response of CR-39 to 1-5.5 MeV alphas

    International Nuclear Information System (INIS)

    Rojas-Herrera, J.; Rinderknecht, H. G.; Zylstra, A. B.; Gatu Johnson, M.; Orozco, D.; Rosenberg, M. J.; Sio, H.; Seguin, F. H.; Frenje, J. A.; Li, C. K.; Petrasso, R. D.

    2015-01-01

    The CR-39 nuclear track detector is used in many nuclear diagnostics fielded at inertial confinement fusion (ICF) facilities. Large x-ray uences generated by ICF experiments may impact the CR-39 response to incident charged particles. To determine the impact of x-ray exposure on the CR-39 response to alpha particles, a thick-target bremsstrahlung x-ray generator was used to expose CR-39 to various doses of 8 keV Cu-K α and K β x-rays. The CR-39 detectors were then exposed to 1-5.5 MeV alphas from an Am-241 source. The regions of the CR-39 exposed to x-rays showed a smaller track diameter than those not exposed to x-rays: for example, a dose of 3.0 ± 0.1 Gy causes a decrease of (19 ± 2)% in the track diameter of a 5.5 MeV alpha particle, while a dose of 60.0 ± 1.3 Gy results in a decrease of (45 ± 5)% in the track diameter. The reduced track diameters were found to be predominantly caused by a comparable reduction in the bulk etch rate of the CR-39 with x-ray dose. A residual effect depending on alpha particle energy is characterized using an empirical formula

  1. Energy response study of modified CR-39 neutron personnel dosimeter

    International Nuclear Information System (INIS)

    Sathian, Deepa; Bakshi, A.K.; Datta, D.; Nair, Sreejith S.; Sathian, V.; Mishra, Jitendra; Sen, Meghnath

    2018-01-01

    Personnel neutron dosimetry is an integral part of radiation protection. No single dosimeter provides the satisfactory energy response, sensitivity, angular dependence characteristics and accuracy necessary to meet the requirement of an ideal personnel neutron dosimeter. The response of a personnel neutron dosimeter is critically dependent upon the energy distribution of the neutron field. CR-39 personnel neutron dosimeters were typically calibrated in the standard neutron field of 252 Cf and 241 Am-Be in our laboratory, although actual neutron fields may vary from the calibration neutron spectrum. Recently the badge cassette of the personnel neutron dosimeter was changed due to frequent damage of the PVC badge used earlier. This paper discusses energy response of CR-39 solid state nuclear track detector loaded in this modified badge cassette as per latest ISO recommendation

  2. Alpha particle track coloration in CR-39: Improved observability

    CERN Document Server

    Oezguemues, A

    1999-01-01

    A comparative study of the observability of alpha particle tracks in CR-39 was performed with an optical microscope before and after coloration. The implantation of ink helped in observing the damage zones. At first glance through the microscope, the coloration makes the tracks stand out right away. This coloration is helpful, from the start, in the morphological study of the tracks (size, area, orientation, shape, perimeter). This operation is advantageous in distinguishing the alpha particle tracks from stains or scratches. Thus, the routine counting of the tracks is more easily performed. Consequently, this procedure allowed us: to decrease significantly the standard deviation of the approximate total of the parameters given from the image analysis system (Olympus CUE2); to envision the possibility of reasonably decreasing the etching time in order to limit the loss of information caused by the destruction of the CR-39 during chemical etching and to use a weaker enlarging lens in order to cover a larger fi...

  3. Etching characteristics of nuclear tracks in CR-39 plastics

    International Nuclear Information System (INIS)

    Tsuruta, Takao; Isobe, Ginko.

    1984-01-01

    In using CR-39 plastics for individual neutron dosimeters, changes of etching efficiency cause significant error in dose estimation. Etching efficiency is subject to a number of parameters. In this study the influences of the parameters were examined by measuring the diameters of etch-pits formed by alpha-particles and enlarged by aqueous solutions of 25-35% KOH at 55-65 0 C for 4 hr. It has been observed that diameter changes at the rate of 8.3%/ 0 C in temperature, 8.2%/wt% in concentration and -0.60%/day in time after preparation of etchant. The diameter is unaffected by the supplying of up to 280ml/l, of distilled water for evaporation of etchant or by increase up to 5g/l of CR-39 dissolved in etchant. The magnitude of possible error has been estimated by parameter as well as in general, so as to obtain suggestions for improving etching treatment. (author)

  4. Development of optical monitor of alpha radiations based on CR-39.

    Science.gov (United States)

    Joshirao, Pranav M; Shin, Jae Won; Vyas, Chirag K; Kulkarni, Atul D; Kim, Hojoong; Kim, Taesung; Hong, Seung-Woo; Manchanda, Vijay K

    2013-11-01

    Fukushima accident has highlighted the need to intensify efforts to develop sensitive detectors to monitor the release of alpha emitting radionuclides in the environment caused by the meltdown of the discharged spent fuel. Conventionally, proportional counting, scintillation counting and alpha spectrometry are employed to assay the alpha emitting radionuclides but these techniques are difficult to be configured for online operations. Solid State Nuclear Track Detectors (SSNTDs) offer an alternative off line sensitive technique to measure alpha emitters as well as fissile radionuclides at ultra-trace level in the environment. Recently, our group has reported the first ever attempt to use reflectance based fiber optic sensor (FOS) to quantify the alpha radiations emitted from (232)Th. In the present work, an effort has been made to develop an online FOS to monitor alpha radiations emitted from (241)Am source employing CR-39 as detector. Here, we report the optical response of CR-39 (on exposure to alpha radiations) employing techniques such as Atomic Force Microscopy (AFM) and Reflectance Spectroscopy. In the present work GEANT4 simulation of transport of alpha particles in the detector has also been carried out. Simulation includes validation test wherein the projected ranges of alpha particles in the air, polystyrene and CR-39 were calculated and were found to agree with the literature values. An attempt has been further made to compute the fluence as a function of the incidence angle and incidence energy of alphas. There was an excellent correlation in experimentally observed track density with the simulated fluence. The present work offers a novel approach to design an online CR-39 based fiber optic sensor (CRFOS) to measure the release of nanogram quantity of (241)Am in the environment. © 2013 Elsevier Ltd. All rights reserved.

  5. The possibility of using plastic detectors CR-39 as UV dosimeters

    International Nuclear Information System (INIS)

    Shweikani, R.; Raja, G.; Sawaf, A.A.

    2004-01-01

    The effects of solar ultraviolet (SUV) and ultraviolet type A (UVA) produced by a solar UV simulator on CR-39 detectors were studied. This was done using three techniques: 1 - Alpha tracks diameters and tracks densities, 2 - UV-Vis spectrometry and 3 - FTIR spectrometry. The detectors were divided into two groups, the first was exposed to UV and then to alpha particles, the second group was exposed to alpha particles first and then to UV. The results showed that the effect of UVA on CR-39 was not clear using the three techniques. While, the effect of SUV was clear when using UV-Vis and FTIR spectrometric, and not clear when using track parameters. (author)

  6. The possibility of using plastic detectors CR-39 as UV dosimeters

    International Nuclear Information System (INIS)

    Shweikani, R.; Raja, G.; Sawaf, A.A.

    2002-01-01

    The effects of solar ultraviolet (SUV) and ultraviolet type A (UVA) produced by a solar UV simulator on CR-39 detectors were studied. This was done using three techniques: 1 - Alpha tracks diameters and tracks densities, 2 - UV-Vis spectrometry and 3 - FTIR spectrometry. The detectors were divided into two groups, the first was exposed to UV and then to alpha particles, the second group was exposed to alpha particles first and then to UV. The results showed that the effect of UVA on CR-39 was not clear using the three techniques. While, the effect of SUV was clear when using UV-Vis and FTIR spectrometric, and not clear when using track parameters

  7. On registration properties of Intercast Company CR-39

    International Nuclear Information System (INIS)

    Golovchenko, A.N.

    1991-01-01

    The CR-39 response function has been determined by using the accelerated particles of intermediate ( 2 H, 4 He, 12 C, 16 O, 20 Ne and 40 Ar) and relativistic ( 19 F) energies. The irradiated detectors were etched in 6N NaOH kept at 70 deg C. The response function is determined in a wide range of the ionization change. 10 refs.; 1 fig.; 2 tabs

  8. Beam profile measurement with CR-39 track detector for low-energy ions

    CERN Document Server

    Sato, F; Tanaka, T; Iida, T; Yamauchi, T; Oda, K

    1999-01-01

    A CR-39 track detector was successfully used to measure the outline of thin low-energy ion beams. After the etching, the surface of the detector was examined with an observation system composed of a Normarski microscope, a CCD camera and a digital image processing computer. Beam images obtained with the system were in good agreement on the outline of the beam formed with a beam aperture. Also, the resolving power in the beam outline measurement was roughly explained from the consideration of the ion range and the etch-pit growth in the chemical etching for the CR-39 detector.

  9. Troca iônica em zeólitas NaY e CrY. Termodinâmica

    Directory of Open Access Journals (Sweden)

    Lucia Tagami

    2001-05-01

    Full Text Available Isotermas de troca iônica de zeólita Y foram investigadas a diferentes temperaturas. As trocas diretas de cromo em NaY apresentaram uma grande seletividade ao Cr3+. Foi também observado que a troca é proporcional ao aumento da temperatura. Por outro lado, as trocas reversas em zeólitas Cr-NaY não são preferenciais. Em ambos os casos, os diagramas de Kielland bem como as propriedades termodinâmicas entalpia padrão (ΔHo, energia livre padrão (ΔGo e entropia padrão (ΔSo de troca iônica foram calculados. As propriedades termodinâmicas mostram um processo favorável para a troca direta. O processo reverso de troca é pouco sensível às mudanças de temperatura devido à alta energia necessária à substituição de 3Na+ por apenas um Cr3+ na zeólita

  10. Personnel neutron dosimetry applications of track-size distributions on electrochemically etched CR-39 foils

    International Nuclear Information System (INIS)

    Hankins, D.E.; Homann, S.G.; Westermark, J.

    1988-01-01

    The track-size distribution on electrochemically etched CR-39 foils can be used to obtain some limited information on the incident neutron spectra. Track-size distributions on CR-39 foils can also be used to determine if the tracks were caused by neutrons or if they are merely background tracks (which have a significantly different track-size distribution). Identifying and discarding the high-background foils reduces the number of foils that must be etched. This also lowers the detection limit of the dosimetry system. We have developed an image analyzer program that can more efficiently determine the track density and track-size distribution, as well as read the laser-cut identification numbers on each foil. This new image analyzer makes the routine application of track-size distributions on CR-39 foils feasible. 2 refs., 3 figs

  11. Response of CR-39 SSNTD to high energy neutrons using zirconium convertors - a Monte Carlo and experimental study

    International Nuclear Information System (INIS)

    Pal, Rupali; Sapra, B.K.; Bakshi, A.K.; Datta, D.; Biju, K.; Suryanarayana, S.V.; Nayak, B.K.

    2016-01-01

    Neutron dosimetry in ion accelerators is a challenging field as the neutron spectrum varies from thermal, to fast and high-energy neutrons usually extending beyond 20 MeV. Solid-state Nuclear Track Detectors (SSNTDs) have been increasingly used in numerous fields related to nuclear physics. Extensive work has also been carried out on determining the response characteristics of such detectors as nuclear spectrometers. In nuclear reaction studies, identification of reaction products according to their type and energy is frequently required. For normally incident particles, energy-dispersive track-diameter methods have become useful scientific tools using CR-39 SSNTD. CR-39 along with 1 mm polyethylene convertor can cover a neutron energy range from 100 keV to 10 MeV. The neutron interacts with the hydrogen in CR-39 producing recoil protons from elastic collisions. This detectable neutron energy range can be increased by modification in the radiator/convertor used along with CR-39. CR39 detectors placed in conjunction with judiciously chosen thicknesses of a polyethylene radiator and a lead absorber (or degrader) are used to increase energy range upto 19 MeV. A portable neutron counter has been proposed for high-energy neutron measurement with 1 cm thick Zirconium (Zr) as the converter outside a spherical HDPE shell of 7 inch diameter. Zr metal has been found to show (n,2n) cross section for energies above 10 MeV starting from 0.01 barns for 8 MeV upto 1 barns for 22 MeV. Above these energies, the experimental data is scarce. In this paper, Zr was used in conjunction with CR-39 which showed an enhancement of track density on the CR-39. This paper demonstrates the enhancement of neutron response using Zr on CR-39 with both theoretical and experimental studies

  12. Response of CR-39 based personnel neutron dosemeter in terms of directional dose equivalent, in free air and on phantom

    International Nuclear Information System (INIS)

    Pal, Rupali R.; Sathian, Deepa; Jayalakshmi, V.; Chougaonkar, M.P.

    2011-01-01

    CR-39 is the most sensitive of nuclear track detectors for protons and is recommended as an effective neutron dosimeter because of it's low threshold energy of 100 keV neutrons. The fraction of protons that gives detectable tracks in CR-39 depends on the energy of the proton angle of incidence and etching conditions. As a consequence the registration efficiency of neutrons in the CR-39 plastics used for neutron personnel monitoring is strongly influenced by the direction of radiation incidence. This paper presents the relative response of CR-39 at varying neutron incident angles, for 241 Am-Be neutron source spectra in free air and on ISO phantom, in terms of operational quantities. It is observed that the angular dependence of CR-39 for irradiations in air and on phantom is essentially the same indicating that the phantom does not affect the directional response of CR-39. (author)

  13. An energy and direction independent fast neutron dosemeter based on electrochemically etched CR-39 nuclear track detectors

    International Nuclear Information System (INIS)

    James, K.; Matiullah; Durrani, S.A.

    1987-01-01

    A computer-based model is presented, which simulates the dose equivalent response of electrochemically etched CR-39 to fast neutrons of various energies and angles of incidence. Most previous calculations of the response of CR-39 have neglected the production of recoiling oxygen and carbon nuclei as well as α particles in the CR-39. We calculate that these 'heavy recoils' and α particles are the major source of electrochemically etchable tracks in bare CR-39 at neutron energies above approx. 2 MeV under typical etching conditions. Our calculations have been extended to predict the response of CR-39 used in conjunction with various combinations of polymeric front radiators and we have determined the radiator stack configuration with produces the most energy independent response. Again, the heavy recoils and α particles cannot be neglected and, for energies above approx. 2 MeV, these produce typically about 20% of the total response of our optimum stack. This type of fast neutron dosemeter is, however, strongly direction dependent. We have integrated the response over all appropriate angles to predict the dose equivalent response for two representative neutron fields, and we suggest a method for minimising the angular dependence. (author)

  14. Impact of x-ray dose on the response of CR-39 to 1–5.5 MeV alphas

    Energy Technology Data Exchange (ETDEWEB)

    Rojas-Herrera, J., E-mail: jimmy06@mit.edu; Rinderknecht, H. G.; Zylstra, A. B.; Gatu Johnson, M.; Orozco, D.; Rosenberg, M. J.; Sio, H.; Seguin, F. H.; Frenje, J. A.; Li, C. K.; Petrasso, R. D. [Plasma Science and Fusion Center, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139 (United States)

    2015-03-15

    The CR-39 nuclear track detector is used in many nuclear diagnostics fielded at inertial confinement fusion (ICF) facilities. Large x-ray fluences generated by ICF experiments may impact the CR-39 response to incident charged particles. To determine the impact of x-ray exposure on the CR-39 response to alpha particles, a thick-target bremsstrahlung x-ray generator was used to expose CR-39 to various doses of 8 keV Cu-K{sub α} and K{sub β} x-rays. The CR-39 detectors were then exposed to 1–5.5 MeV alphas from an Am-241 source. The regions of the CR-39 exposed to x-rays showed a smaller track diameter than those not exposed to x-rays: for example, a dose of 3.0 ± 0.1 Gy causes a decrease of (19 ± 2)% in the track diameter of a 5.5 MeV alpha particle, while a dose of 60.0 ± 1.3 Gy results in a decrease of (45 ± 5)% in the track diameter. The reduced track diameters were found to be predominantly caused by a comparable reduction in the bulk etch rate of the CR-39 with x-ray dose. A residual effect depending on alpha particle energy is characterized using an empirical formula.

  15. Detection of heavy nuclei in the plastic track detector CR-39

    International Nuclear Information System (INIS)

    Fumuro, F.; Ihara, R.; Ohta, I.; Sato, Y.; Tezuka, I.; Tasaka, S.; Sugimoto, H.

    1982-01-01

    Relativistic cosmic ray nuclei were detected in an emulsion chamber composed of a pile of solid state track detectors (CR-39) and the emulsion plates. The 460 heavy nuclei were observed by scanning of emulsion and CR-39 plastic plates. The normalized track etch rate (Vsub(t)/Vsub(b))-1 for relativistic iron group was measured as 1.3+-0.05 and bulk etch rate Vsub(b) as 1.63+-0.08 μm/hour after 32 hours etch in 6.8 N NaOH at 70 0 C. The charge detection threshold was obtained to be Z=6 for β=1 with the dip angle larger than 75 degrees. The charge resolution was estimated to be Δ Z=0.7 for iron, and Δ Z=0.4 for magnesium and silicon nuclei

  16. Proton Radiography with CR-39 by Using the Protons from High Power Femto-second Laser System

    International Nuclear Information System (INIS)

    Choi, Chang Il; Lee, Dong Hoon; Kang, Byoung Hwi; Kim, Yong Kyun; Choi, Il Woo; Ko, Do Kyeong; Lee, Jong Min

    2008-01-01

    Proton radiography techniques are useful to obtain a high quality image of a thin object, because protons travel straight in matter. Generation of the high energy proton using conventional accelerator costs high and requires large accelerating facility. But proton radiography using high power femto-second(10-15 second) laser has been interested, because it can generate high energy protons at lower price than the conventional accelerator like a cyclotron. For this study, we used the CR-39 SSNTD (Solid State Nuclear Track Detector) as the proton radiography screen. Commonly, CR-39 is used to detect the tracks of energetic charged particles. Incident energetic charged particles left latent tracks in the CR-39, in the form of broken molecular chains and free radicals. These latent tracks show high chemical reactivity. After chemical etching with the caustic alkali solution such as NaOH or KOH, tracks are appeared to forms of hole. If protons with various energies enter the two targets with another thickness, number of protons passed through the target per unit area is different each other. Using this feature of protons, we can a proton radiographic image with CR-39. We studied proton radiography with CR-39 by using energetic protons from high power femto-second laser and evaluated potentiality of femto-second laser as new energetic proton generator for radiography

  17. Efficient alpha particle detection by CR-39 applying 50 Hz-HV electrochemical etching method

    International Nuclear Information System (INIS)

    Sohrabi, M.; Soltani, Z.

    2016-01-01

    Alpha particles can be detected by CR-39 by applying either chemical etching (CE), electrochemical etching (ECE), or combined pre-etching and ECE usually through a multi-step HF-HV ECE process at temperatures much higher than room temperature. By applying pre-etching, characteristics responses of fast-neutron-induced recoil tracks in CR-39 by HF-HV ECE versus KOH normality (N) have shown two high-sensitivity peaks around 5–6 and 15–16 N and a large-diameter peak with a minimum sensitivity around 10–11 N at 25°C. On the other hand, 50 Hz-HV ECE method recently advanced in our laboratory detects alpha particles with high efficiency and broad registration energy range with small ECE tracks in polycarbonate (PC) detectors. By taking advantage of the CR-39 sensitivity to alpha particles, efficacy of 50 Hz-HV ECE method and CR-39 exotic responses under different KOH normalities, detection characteristics of 0.8 MeV alpha particle tracks were studied in 500 μm CR-39 for different fluences, ECE duration and KOH normality. Alpha registration efficiency increased as ECE duration increased to 90 ± 2% after 6–8 h beyond which plateaus are reached. Alpha track density versus fluence is linear up to 10 6  tracks cm −2 . The efficiency and mean track diameter versus alpha fluence up to 10 6  alphas cm −2 decrease as the fluence increases. Background track density and minimum detection limit are linear functions of ECE duration and increase as normality increases. The CR-39 processed for the first time in this study by 50 Hz-HV ECE method proved to provide a simple, efficient and practical alpha detection method at room temperature. - Highlights: • Alpha particles of 0.8 MeV were detected in CR-39 by 50 Hz-HV ECE method. • Efficiency/track diameter was studied vs fluence and time for 3 KOH normality. • Background track density and minimum detection limit vs duration were studied. • A new simple, efficient and low-cost alpha detection method

  18. Studies of isothermal annealing of fission fragment and alpha particle tracks in Cr-39 polymer detectors

    International Nuclear Information System (INIS)

    Zaky, M.F.; Youssef, A.A.

    2002-01-01

    Two groups of CR-39 detectors samples are exposed to two types of charged particle radiation. The first group are severe damaged with fission fragment tracks from 2 52C f source. The second accepted alpha particles resulting from the interaction of highly energetic 1 9F -ions and a copper disk with thickness 1 cm, which are of less damage tracks than fission fragments. , The isothermal annealing of tracks in the temperature range from 175 to 300 degree C in step 25 degree C for annealing time of 10,15,20,25 and 30 minutes has been investigated. The changes introduced in the track density and track diameter for two types of irradiation in the detector have been observed and compared between them. The results indicate that the track density and the size of the tracks are considerably changed due to annealing

  19. Observation of anomalons in CR-39 track detectors

    International Nuclear Information System (INIS)

    Tincknell, M.L.; Price, P.B.

    1984-01-01

    The authors have observed fragments of 1.85 GeV/nucleon 40 Ar in CR-39 etched track detector and they find anomalously short mean free paths (mfp's) of secondary nuclei with 11 less than or equal to Z less than or equal to 17 in the first 2 cm after their production, at approx.3 standard deviations. This confirms previous reports of this anomalon effect in nuclear emulsion in a new detector with dissimilar potential systematic errors

  20. Fast Neutron Dosimetry Using CR-39 Nuclear Track Detector

    International Nuclear Information System (INIS)

    ZAKI, M.; ABDEL-NABY, A.; MORSY, A.

    2010-01-01

    Measurement of the neutron dose in and around the neutron sources is important for the purpose of personnel and environmental neutron dosimetry. In the present study, a method for the measurement of neutron dose using the UV-Vis spectra of CR-39 plastic track detector was investigated. A set of CR-39 plastic detectors was exposed to 252 Cf neutron source, which had the yield of 0.68x10 8 /s, and neutron dose equivalent rate 1m apart from the source is equal to 3.8 mrem/h. The samples were etched for 10 h in 6.25 N NaOH at 70 o C. The absorbance of the etched samples was measured using UV-visible spectrophotometer as a function of neutron dose. It was observed that there was a linear relationship between the optical absorption of these detectors and neutron dose. This means that the exposure dose of neutron can be determined by knowing the optical absorption of the sample. These results were compared with previous study. It was found that there was a matching and good agreement with their investigations.

  1. Operational trials of single- and multi-element CR-39 dosemeters for the DIDO and PLUTO reactors at the Harwell Laboratory

    International Nuclear Information System (INIS)

    Gallacher, G.G.; Perks, C.A.

    1993-01-01

    Single- and multi-element CR-39 dosemeters, developed at the Harwell Laboratory, and a commercially available multi-element CR-39 dosemeter (obtained from Track Analysis Systems Ltd), were evaluated for their potential as neutron dosemeters for personnel working at Harwell Laboratory's research reactors. Owing to the angular dependence of the CR-39 (processed using electrochemical etching), the single-element dosemeter was found to be impractical. Consequently, a multi-element dosemeter was developed, which consisted of a cube of side 36 mm with CR-39 elements (also processed using electrochemical etching) attached to each of the sides. Although this dosemeter was technically suitable for this type of dosimetry, it was considered to be unacceptably bulky in personnel trials. The commercially available CR-39 dosemeter tested was much smaller (the CR-39 was only chemically etched) and this was considered to be acceptable as a personnel dosemeter. In addition, trials with personnel working at active handling glove boxes indicated that single-element dosemeters might be adequate, but further work would be needed to verify this. (author)

  2. Bulk etching characteristics of CR-39 track detectors in hydroxide solutions

    International Nuclear Information System (INIS)

    Fonseca, E.S. da; Knoefel, T.M.J.; Tavares, O.A.P.

    1983-01-01

    A systematic study of the bulk etch rate of CR-39 track detectors in KOH and NaOH aqueous solutions is presented. A number of unirradiated and non-thermally treated CR-39 samples were chemically attacked in KOH and NaOH solutions of concentration and temperature in the range 2-10 N and 50-90 0 C, respectively. From measurements of the thickness of layers removed as a function of the etching time, the bulk etch rate υ β and the induction time T ο for surface removal were obtained for each etching condition. For both NaOH and KOH solution the activation energy of the process was derived as E = 0.76 ± 0.05 eV. It was observed that the induction time decreases both with increasing normality and temperature of the solution. (author) [pt

  3. Personal Dosemeter of Thermal Neutron Using A Cr-39 Detector with Filter Natural LiF

    International Nuclear Information System (INIS)

    Sofyan, Hasnel; Thamrin, M.Thoyib

    1996-01-01

    The research of personal dosemeter for thermal neutron using Cr-39 detector with different thicknesses of natural LiF filter was carried out. The irradiation of Cr-39 detector with neutron source from reactor research TRIGA mark II of Rikkyo University Tokyo, Japan. Nuclear track was counted by automatic method with ASPECT ver.4.22 Series A4T124 software and manual method for correction. The result of research, the maximum of nuclear tracks was obtained at 8 mm of LiF filter was 10 mm with 11,630x10E-5 track/neutron for air radiation. And on phantom radiation, the thickness of filter was 10 mm with 11,630x10E-5 track/neutron. Its values were 3.6 and 7.5 bigger than the response of Cr-39 non filter in air and on phantom radiation, respectively

  4. CR-39 and Lexan calibrated as low-LET radiation dosimeter, for three Mexican irradiation facilities

    International Nuclear Information System (INIS)

    Tavera, L.; Balcazar, M.; Matamoros, H.; Carrasco, H.

    2005-01-01

    An experimental calibration of two common nuclear track detectors, CR-39 and Lexan, for gamma and electrons radiation, was performed using various irradiation facilities. The dose response was obtained as a function of two parameters, the bulk etch rate and the UV absorbance for a wide dose range from 10 to 1000 kGy. The bulk etch rate sensitivity, for gamma and electrons, in CR-39 detector is higher than for Lexan detector. Lexan has a well-defined UV absorbance spectrum, but presents saturation for doses higher than 500 kGy, the same saturation characteristic is observed for the corresponding bulk etch rate response. For electron and gamma radiation, CR-39 shows a good response for doses from 10 kGy up to 1000 kGy, where data fit well an exponential curve for electrons and a lineal curve for gamma radiation

  5. Characterization of a alpha particle detector CR-39 exposed to a source of radium

    International Nuclear Information System (INIS)

    Maino, Leandro Marcondes

    2009-01-01

    In this project, the main goal is the characterization of a alpha particle detector CR-39 exposed to a source of radio. Three detectors were exposed to a source of radium and then chemically treated for different periods. This way, we could analyze these samples and collect the information needed to verify that at least one of the chemical attack, there has been a separation of the energies alpha particles incident with distinct peaks, thus characterizing the CR-39 as alpha spectrometer in the range 2.5 to 6.3 MeV . (author)

  6. Present status of fast neutron personnel dosimetry system based on CR-39 solid state nuclear track detectors

    International Nuclear Information System (INIS)

    Pal, Rupali; Sathian, Deepa; Jayalakshmi, V.; Bakshi, A.K.; Chougaonkar, M.P.; Mayya, Y.S.; Kumar, Valli; Babu, Rajesh; Kar, S.; Joshi, V.M.

    2011-08-01

    Neutron sources are of different types depending upon the method of production such as nuclear reactors, particle accelerators and laboratory sources. Neutron sources depending upon their energy, flux, size etc. are used for variety of applications in basic and applied sciences, neutron scattering experiments and in industry such as oil well - digging, coal mining and processing, ore processing etc. Personnel working in nuclear installations such as reactors, accelerators, spent fuel processing plants, nuclear fuel cycle operations and those working in various industries such as oil refining, oil well-digging, coal mining and processing, ore processing, etc. need to be monitored for neutron exposures, if any. Neutron monitoring is especially necessary in view of the fact that the radiation weighting factor for neutron is much higher than gamma rays and also it varies with energy. Radiological Physics and Advisory Division is involved in monitoring of personnel working in neutron fields. Around 2100 workers from 70 institutions (DAE and Non-DAE) are monitored on a quarterly basis. Neutron personnel monitoring, carried out in the country is based on Solid State Nuclear Track Detection (SSNTD) technique. In this technique, neutrons interact with hydrogen in CR-39 polymer to produce recoil protons. These protons create damages in the polymer, which are enlarged and appear as tracks when subjected to electrochemical etching (ECE). These tracks are counted in an optical system to evaluate the neutron dose. The neutron dosimetry system based on SSNTD has undergone a significant development, since it was started in 1990. The development includes upgradation of image analysis system for counting tracks, introduction of chemical etching (CE) at elevated temperatures for evaluation of dose equivalents above 10 mSv and use of carbon laser for cutting of CR-39 detectors. The entire dose evaluation process has been standardized, which includes calibration and performance tests

  7. Impact of x-ray dose on track formation and data analysis for CR-39-based proton diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Rinderknecht, H. G., E-mail: rinderknecht1@llnl.gov; Rojas-Herrera, J.; Zylstra, A. B.; Frenje, J. A.; Gatu Johnson, M.; Sio, H.; Sinenian, N.; Rosenberg, M. J.; Li, C. K.; Séguin, F. H.; Petrasso, R. D. [Massachusetts Institute of Technology, Cambridge, Massachusetts 02139 (United States); Filkins, T.; Steidle, Jessica A.; Traynor, N.; Freeman, C. [State University of New York at Geneseo, Geneseo, New York 14454 (United States); Steidle, Jeffrey A. [Rochester Institute of Technology, Rochester, New York 14623 (United States)

    2015-12-15

    The nuclear track detector CR-39 is used extensively for charged particle diagnosis, in particular proton spectroscopy, at inertial confinement fusion facilities. These detectors can absorb x-ray doses from the experiments in the order of 1–100 Gy, the effects of which are not accounted for in the previous detector calibrations. X-ray dose absorbed in the CR-39 has previously been shown to affect the track size of alpha particles in the detector, primarily due to a measured reduction in the material bulk etch rate [Rojas-Herrera et al., Rev. Sci. Instrum. 86, 033501 (2015)]. Similar to the previous findings for alpha particles, protons with energies in the range 0.5–9.1 MeV are shown to produce tracks that are systematically smaller as a function of the absorbed x-ray dose in the CR-39. The reduction of track size due to x-ray dose is found to diminish with time between exposure and etching if the CR-39 is stored at ambient temperature, and complete recovery is observed after two weeks. The impact of this effect on the analysis of data from existing CR-39-based proton diagnostics on OMEGA and the National Ignition Facility is evaluated and best practices are proposed for cases in which the effect of x rays is significant.

  8. Impact of x-ray dose on track formation and data analysis for CR-39-based proton diagnostics

    International Nuclear Information System (INIS)

    Rinderknecht, H. G.; Rojas-Herrera, J.; Zylstra, A. B.; Frenje, J. A.; Gatu Johnson, M.; Sio, H.; Sinenian, N.; Rosenberg, M. J.; Li, C. K.; Séguin, F. H.; Petrasso, R. D.; Filkins, T.; Steidle, Jessica A.; Traynor, N.; Freeman, C.; Steidle, Jeffrey A.

    2015-01-01

    The nuclear track detector CR-39 is used extensively for charged particle diagnosis, in particular proton spectroscopy, at inertial confinement fusion facilities. These detectors can absorb x-ray doses from the experiments in the order of 1–100 Gy, the effects of which are not accounted for in the previous detector calibrations. X-ray dose absorbed in the CR-39 has previously been shown to affect the track size of alpha particles in the detector, primarily due to a measured reduction in the material bulk etch rate [Rojas-Herrera et al., Rev. Sci. Instrum. 86, 033501 (2015)]. Similar to the previous findings for alpha particles, protons with energies in the range 0.5–9.1 MeV are shown to produce tracks that are systematically smaller as a function of the absorbed x-ray dose in the CR-39. The reduction of track size due to x-ray dose is found to diminish with time between exposure and etching if the CR-39 is stored at ambient temperature, and complete recovery is observed after two weeks. The impact of this effect on the analysis of data from existing CR-39-based proton diagnostics on OMEGA and the National Ignition Facility is evaluated and best practices are proposed for cases in which the effect of x rays is significant

  9. Directional Track Selection Technique in CR39 SSNTD for lowyield reaction experiments

    Science.gov (United States)

    Ingenito, Francesco; Andreoli, Pierluigi; Batani, Dimitri; Bonasera, Aldo; Boutoux, Guillaume; Burgy, Frederic; Cipriani, Mattia; Consoli, Fabrizio; Cristofari, Giuseppe; De Angelis, Riccardo; Di Giorgio, Giorgio; Ducret, Jean Eric; Giulietti, Danilo; Jakubowska, Katarzyna

    2018-01-01

    There is a great interest in the study of p-11B aneutronic nuclear fusion reactions, both for energy production and for determination of fusion cross-sections at low energies. In this context we performed experiments at CELIA in which energetic protons, accelerated by the laser ECLIPSE, were directed toward a solid Boron target. Because of the small cross-sections at these energies the number of expected reactions is low. CR39 Solid-State Nuclear Track Detectors (SSNTD) were used to detect the alpha particles produced. Because of the low expected yield, it is difficult to discriminate the tracks due to true fusion products from those due to natural background in the CR39. To this purpose we developed a methodology of particle recognition according to their direction with respect to the detector normal, able to determine the position of their source. We applied this to the specific experiment geometry, so to select from all the tracks those due to particles coming from the region of interaction between accelerated protons and solid boron target. This technique can be of great help on the analysis of SSNTD in experiments with low yield reactions, but can be also generally applied to any experiment where particles reach the track detector with known directions, and for example to improve the detection limit of particle spectrometers using CR39.

  10. Suitability of CR-39 dosimeters for personal dosimetry around CANDU reactors

    International Nuclear Information System (INIS)

    Cross, W.G.

    1992-08-01

    The capabilities and limitations of CR-39 damage track detectors have been evaluated for their use as personal neutron dosimeters around CANDU reactors. Since the energy response is a critical characteristic, the neutron energy spectra expected within CANDU containments were studied. In the boiler rooms, around the moderator cooling systems, and in most of the fueling machine vaults, the spectra vary considerably, but the majority of the dose is expected to be delivered by neutrons above 80 keV, the approximate threshold for electrochemically-etched CR-39 detectors. In the Pickering A fueling machine vault, and in areas in other stations to which neutrons from reactors have been multiply scattered, lower energy neutrons may be important. In nearly all areas where people work, it appears that working times will be limited by gamma rays rather than by neutrons. The characteristics of other neutron dosimeters - bubble and superheated drop detectors, albedo detectors, and Si real-time detectors - were also reviewed. For workers who typically receive neutron doses that are small compared with regulatory limits, CR-39 is the most suitable available dosimeter for demonstrating compliance. All single dosimeters have poor angular response over the range 0 to 180 degrees because of the shielding of the body. Albedo and Si detectors have particularly poor energy responses over the energy range of importance. Bubble and superheated drop detectors have the advantages of immediate readout and high sensitivity, but the disadvantages of inability to integrate doses over a long period, temperature dependence, very limited range and higher cost. (Author) (110 refs., 45 figs.)

  11. Exposure of CR39 Stacks to Oxygen and Sulphur Beams at the CERN-SPS

    CERN Multimedia

    2002-01-01

    We plan to expose 8 stacks of CR39 sheets to oxygen and sulphur ions of 60 and 200~GeV at the CERN-SPS.\\\\ \\\\ The main purpose of the exposures is the calibration of the CR39 sheets used for a large area experimental search for magnetic monopoles at the Gran Sasso Laboratory (experiment MACRO). \\\\ \\\\ The stacks have 20~layers of CR39, each layer 13~cm~x~7~cm and 1.4~mm thick. A copper absorber is located after the first 6 layers. \\\\ \\\\ We require exposures of about 2000 tracks per cm$^2$ over the entire area of the stack with a uniform illumination. The standard beam used for the emulsion experiments is normally adequate for this purpose.\\\\ \\\\ We have performed one exposure to sulphur ions. The etched tracks have been measured automatically with the Elbeck image analyser system. We measured the incoming sulphur ions as well as the nuclear fragments produced in the copper absorber. Clean separation among the peaks due to the various fragments is obtained (there is no indication of nuclei with fractional electri...

  12. Wide-range neutron dose determination with CR-39

    International Nuclear Information System (INIS)

    Arneja, A.R.; Waker, A.J.

    1995-01-01

    Optical density measurements of CR-30 irradiated with 252 Cf neutrons and chemically etched with 6.5 N KOH solution have been used to determine neutron absorbed doses between 0.1 and 10 Gy. Optimum etching conditions will depend upon the absorbed dose. Since it is not always possible to know the range of absorbed dose on a CR-39 dosemeter collected from personnel and area monitor stations in a criticality accident situation, a three-step two-hour chemical etch at 60 o C has been found to be appropriate. If after a total of six hours of chemical etching the optical density is found to be below 0.04 for 500 nm light (transmission > 90%) then further treatment in the form of electrochemical etching can be carried out to determine the lower absorbed dose. In this manner, absorbed doses below 0.1 Gy can be determined by counting tracks over a unit area. (author)

  13. Study of the characteristics of ionizing particles record of CR-39 track detectors

    International Nuclear Information System (INIS)

    Brandao, Luis Eduardo Barreira

    1983-01-01

    The bulk and track etching proprieties of a new Solid State Nuclear Track Detector CR-39 were investigated under different etching conditions. The discussion is based on results obtained using aqueous solutions of KOH with addition of alcoholic solvent to aqueous solutions. It was found that track registration sensitivity can be dramatically changed by using the proper chemical treatment. A method to enlarge and dye etch tracks to be viewed by simple projection on a screen is discussed. The applications of CR-39 in neutron fluence measurements are shown. Graphs are presented of the densities of the registered traces by the detector as a function of etch time both for samples with and without a polycarbonate radiator. (author)

  14. Characteristics of neutron-irradiated CR-39 foils treated by sequential chemical and electrochemical etching

    International Nuclear Information System (INIS)

    Somogyi, G.; Dajko, G.; Turek, K.; Spurny, F.

    1982-01-01

    The density of background spots revealed by chemical (CE) and electrochemical (ECE) etching and by their sequential application (CE + ECE) has been measured in several sorts of CR-39 material. The trends in the variation of sensitivity to Am-Be neutrons have been determined in CR-39 sheets covered by thick proton-radiator, when changing the field strength, frequency, etchant concentration, pre-etch duration and the fluence of neutrons. The results are analyzed in order to find out an optimum set of experimental parameters which may be proposed to attain high registration sensitivity to neutrons. (author)

  15. Coherent light scattering by nuclear etched tracks in the PADC (a form of CR-39)

    Energy Technology Data Exchange (ETDEWEB)

    Groetz, J.E.; Chambaudet, A. [Universite de Franche-Comte, Besancon (France). Lab. de Microanalyses Nucleaires; Lacourt, A. [Laboratoire d`Optique P.M. Duffieux, UMR 6603 CNRS, Universite de Franche-Comte, 16 route de Gray, 25030 Besancon Cedex (France)

    1998-08-01

    A new kind of measurement has been proposed to improve the reading of the solid state nuclear track detector CR-39. This method is based on coherent light scattering (He-Ne laser) by etched proton tracks, and is complementary to observation under an optical microscope and reading by optical density of the CR-39. The irradiated and chemically etched CR-39 sample is illuminated by a laser beam under a normal incidence angle. The light intensity diffracted by the tracks beyond the sample - defined with the bi-directional transmissive distribution functions - is measured with a photodiode. Thus, the bi-directional transmissive distribution functions depend on the characteristics of the irradiation, namely the track density, track sizes and orientations. We have performed a track light diffraction model calculation through the use of the Fraunhofer diffraction, Babinet`s principle and the spatial coherence and incoherence. We compared calculations and experimental results for the different shapes of tracks: conical, oblique and spherical-shaped. (orig.) 14 refs.

  16. Coherent light scattering by nuclear etched tracks in the PADC (a form of CR-39)

    International Nuclear Information System (INIS)

    Groetz, J.E.; Chambaudet, A.

    1998-01-01

    A new kind of measurement has been proposed to improve the reading of the solid state nuclear track detector CR-39. This method is based on coherent light scattering (He-Ne laser) by etched proton tracks, and is complementary to observation under an optical microscope and reading by optical density of the CR-39. The irradiated and chemically etched CR-39 sample is illuminated by a laser beam under a normal incidence angle. The light intensity diffracted by the tracks beyond the sample - defined with the bi-directional transmissive distribution functions - is measured with a photodiode. Thus, the bi-directional transmissive distribution functions depend on the characteristics of the irradiation, namely the track density, track sizes and orientations. We have performed a track light diffraction model calculation through the use of the Fraunhofer diffraction, Babinet's principle and the spatial coherence and incoherence. We compared calculations and experimental results for the different shapes of tracks: conical, oblique and spherical-shaped. (orig.)

  17. High resolution alpha-autoradiography for measurement of 10B distribution in subcellular scale using CR-39 and AFM

    International Nuclear Information System (INIS)

    Amemiya, K.; Takahashi, H.; Yasuda, N.

    2000-01-01

    In order to measure 10 B distribution in tumor tissues for BNCT at subcellular scale, we have developed a new method for high resolution alpha-autoradiography using contact X-ray microscopy technique with CR-39 plastic track detectors. Sliced sections of boron-injected brain tumors in rats were mounted on CR-39 and irradiated with thermal neutrons at KUR. Then the samples were exposed to soft X-rays from a laser plasma source. After etching the CR-39 in NaOH solution for a short time (1-5 min.), transmission X-ray image of tumor cells appeared as relief on CR-39 surface, and could be observed with the atomic force microscopy (AFM). Very small etch pits of about 100 nm in diameter corresponding to particle tracks from 10 B(n, α) 7 Li reactions were also observed in the image simultaneously. This method provides an accurate distribution of 10 B inside the cell. (author)

  18. Restauração metalocerâmica: um estudo comparativo da compatibilidade térmica de ligas Ni-Cr e porcelanas odontológicas

    Directory of Open Access Journals (Sweden)

    ROLLO João Manuel Domingos de Almeida

    1999-01-01

    Full Text Available Uma das aplicações tecnológicas em que é necessário haver compatibilidade entre um material cerâmico e um material metálico é a confecção de restaurações odontológicas do tipo metalocerâmica. Neste caso, uma porcelana é fundida sobre um substrato metálico para obtenção da prótese de um dente. O requisito fundamental para o sucesso da união metalocerâmica é a adequação dos coeficientes de expansão térmica de cada um dos materiais, de forma a se obter um estado de tensão de compressão adequado na camada cerâmica. Este trabalho propôs-se a levantar as curvas de expansão térmica de ligas Ni-Cr e porcelanas odontológicas, através da técnica de dilatometria e verificar a possível compatibilidade térmica dos pares metal/cerâmica. Simulando a entrada de um novo produto no mercado, desenvolveu-se uma liga Ni-Cr experimental denominada SR, que foi comparada a uma liga comercial de Ni-Cr bastante utilizada em restaurações metalocerâmicas. A partir da análise das curvas de expansão térmica, foi possível verificar a compatibilidade dos pares metal/cerâmica quanto à dilatação térmica, segundo os conceitos preconizados por YAMAMOTO7 (1985. Sob este aspecto, a liga experimental apresentou valores que a incluem como mais uma opção na família de ligas Ni-Cr para utilização em restaurações metalocerâmicas. Os resultados obtidos indicam que o equipamento e a metodologia utilizados são adequados para análise comparativa da compatibilidade térmica entre ligas metálicas Ni-Cr e porcelanas odontológicas.

  19. CR-39 α track detector and its application in observing of the hot particles in environment

    International Nuclear Information System (INIS)

    Zou Benchuan

    1992-01-01

    CR-39 α track detector is a new α remitting radionuclides plastic detector. It is audio-visual, convenient and economic in the detection of α particle track and the distribution of α emitting radionuclides in environmental samples. CR-39 α track detector is used to observe the hot particles in rock and the hot particles coming from the liquid effluents discharged by spent fuel reprocessing plant in UK in marine environment and got good results

  20. Relation between the size of fog droplets and their contact angles with CR39 surfaces

    International Nuclear Information System (INIS)

    Grosu, G; Andrzejewski, L; Veilleux, G; Ross, G G

    2004-01-01

    The formation of fog on CR39 surfaces has been studied. Water droplets form fog coalesce with time, especially during the first 20 s at the beginning of the formation of fog. Consequently, their mean diameter increases. Formation of fog being related to the wettability of the surfaces, the latter has been increased by the implantation of Ar ions into CR39 surfaces under an oxygen partial pressure. A very wetting CR39 surface with advancing (ACA) and receding (RCA) contact angles below 5 deg. has been obtained with an implantation dose of 1.28x10 17 Ar + cm -2 . In this condition, no formation of fog was observed. Characterization using x-ray photoelectron spectroscopy has shown that the molecular structure of CR39 is strongly modified by Ar + implantation, which would be responsible for the increase in wettability. Unfortunately, both ACA and RCA increase with time, which is called ageing, and the formation of fog is again observed. The diameter and concentration of water droplets forming fog have been plotted against the contact angle. These plots show that no formation of fog occurs for ACA 15 He + cm -2 and an energy of 2 keV, sufficient to push the ions deeper than the Ar depth profile, delays the ageing effect in such a way that ACA ≅ 40 deg. is reached after ∼2000 h and no formation of fog is observed during these first ∼2000 h

  1. Angular and dose dependence of CR-39 neutron response for shape-selected tracks

    CERN Document Server

    Tam, N C; Lakosi, L

    1999-01-01

    A shape selection method corresponding to an energy discrimination was used to eliminate unwanted events disturbing evaluation of CR-39 detectors in detecting tracks induced by particles both of perpendicular and oblique incidence. The angular dependence of the response was examined, detecting fast neutrons from sup 2 sup 5 sup 2 Cf with shape selection technique at various angles and distances. Also, the CR-39 track detectors with the sup 2 sup 5 sup 2 Cf source were exposed to high gamma-intensity of a sup 6 sup 0 Co irradiation facility in the range 0.1 to 4.5 kGy, similar to the exposures inside spent fuel assemblies. Using the two functions the lower limit of burnup could be determined by the method.

  2. Energy-dependent etching-related impacts on CR-39 alpha detection efficiency for the Rn-222 and Rn-220 decay chains

    Science.gov (United States)

    Tan, Y.; Yuan, H.; Kearfott, K. J.

    2018-04-01

    CR-39 detectors are widely used to measure environmental levels of Rn-222, Rn-220 and their progeny. Prior research reported the CR-39 detection efficiency for alpha particles from Rn-222, Rn-220 and their progeny under a variety of etching conditions. This paper provides an explanation for interesting observations included in that work, namely that the critical incidence angle decreases with the increasing particle energy and the detection efficiency for 8.78 MeV alpha particles is zero. This paper explains these phenomena from a consideration of the interaction of alpha particles with the CR-39 detectors and the physics of etching dynamics. The proposed theory provides a rationale for an approach to optimizing the etching conditions of CR-39 detector for measuring Rn-222, Rn-220 and their progenies.

  3. Effect of certain production parameters and post-production treatments on the etching characteristics of CR-39 sheets

    Energy Technology Data Exchange (ETDEWEB)

    Somogyi, G.; Toth-Szilagyi, M.; Hunyadi, I.; Hafez, A.-F.

    1986-01-01

    There is a permanent need in producing track recording detectors of well defined behaviour from CR-39 monomer. Therefore, more studies on the role of production parameters determining the stability of main etching characteristics (bulk etch rate, Vsub(B);etch rate ratio, Vsub(T)/Vsub(B);opaqueness after longer etching periods) are highly required. In our studies we have examined different commercial CR-39 sheets (Homalite, Pershore, MA-ND) to compare their registration sensitivity to selected alpha and proton energies. In addition, we have investigated the main etching parameters of CR-39 sheets manufactured under different casting conditions varying the concentration of initiator and certain additives. Finally, the effect of some post-production treatments, annealing and storage in vacuum, on the Vsub(B) and Vsub(T)/Vsub(B) values is studied.

  4. Studies of biocompatibility of chemically etched CR-39 SSNTDs in view of their applications in alpha-particle radiobiological experiments

    International Nuclear Information System (INIS)

    Li, W.Y.; Chan, K.F.; Tse, A.K.W.; Fong, W.F.; Yu, K.N.

    2006-01-01

    Alpha-particle radiobiological experiments involve irradiating cells with alpha particles and require thin biocompatible materials which can record alpha-particle traversals as substrates for cell cultures. The biocompatibilities of chemically etched CR-39 solid-state nuclear track detectors (SSNTDs) using aqueous NaOH or NaOH/ehtanol are studied through the abundance and morphology of the cultured HeLa cells. The wetting properties of these etched CR-39 SSNTDs are also studied. The moderately hydrophobic CR-39 SSNTDs as well as the hydrophobic NaOH/ethanol-etched CR-39 SSNTDs are more biocompatible than the hydrophilic aqueous-NaOH-etched SSNTDs. Too small water contact angles, too large surface energy (γ s ) or the polar component γ s p do not favor the cell culture. On the other hand, the dispersive component γ s d of the surface energy and the ratio γ s p /γ s d do not seem to significantly affect the biocompatibility

  5. Calibration of detectors type CR-39 for methodology implementation for Radon-222 determination in CRCN-NE, Brazil

    International Nuclear Information System (INIS)

    Silva, Karolayne E.M. da; Santos, Mariana L. de O.; Amaral, Déric S. do; Vilela, Eldice C.; França, Elvis J. de; Hazin, Clovis A.; Farias, Emerson E.G. de

    2017-01-01

    Radon-222 is a radioactive gas, a product of the decay of uranium-238, which emits alpha particles and represents more than 50% of the dose of natural radiation received by the population. Therefore, monitoring of this gas is essential. For indoor measurement, solid state detectors can be used, the most common of which is CR-39. For monitoring using CR-39, alpha particles, generated by radon-222 and the daughter radionuclides, strike the surface of the detector and generate traces. To relate the trace density per exposure area in environments with unknown activity concentration, it is necessary to determine the calibration factor. The objective of this study was to calibrate CR-39 type detectors for the implementation of the radon determination methodology in Centro Regional de Ciencias Nucleares do Nordeste - CRCN-NE of Brazilian Nuclear Energy Commission - CNEN. In order to determine the CR-39 calibration factor, 19 exposures of the detectors were performed in the CRCN-NE calibration chamber (RN1-CRCN) at an activity of 5.00 kBq m -3 , with the exposure time varying from 24 to 850 hours. For the detection of the detectors, sodium hydroxide was used in a thermostat bath at 90 ° C for 5 hours. The count of number of traits per unit of field was performed with the aid of optical microscopy with an increase of 100 times, being read 30 fields per dosimeters. As a result, the calibration factor was obtained, and the linear response of the trace density as a function of exposure was observed. The results allow the use of CR-39 in the determination of radon-222 by CRCN-NE

  6. Neutron measurement in 12,13C+ 27Al system using CR-39 detectors and neutron rem meter

    International Nuclear Information System (INIS)

    Sahoo, G.S.; Tripathy, S.P.; Shanbhag, A.A.; Sunil, C.; Joshi, D.S.; Sarkar, P.K.

    2011-01-01

    In this work, neutron measurements carried out for the interaction of 60 and 67.5 MeV 12 C, 57.3 and 65 MeV 13 C ions with thick aluminium target by using CR-39 detectors and neutron rem meter is reported. Both the detector systems were irradiated at different angles viz. 0 deg, 30 deg, 60 deg, 90 deg with respect to the beam direction. The normalized track density measurements (tracks/cm 2 /projectile at 1m) in CR-39 detectors were correlated with the normalized dose equivalent values (μSv/projectile at 1m) obtained using the neutron rem meter. The track density was found to be more in case of 13 C than 12 C. However in all the cases, the track density per incident projectile was found to decrease as the angle with respect to beam direction increases, indicating non-isotropic nature of neutron emission. The ratio between measured dose equivalent in rem meter to the measured track densities in CR-39 detectors was found to be 2.8±0.2, which remains constant irrespective of the change in angle from beam direction as well as neutron spectrum, indicating a flat dose response of CR-39 detectors. (author)

  7. Using X-ray photoelectron spectroscopy to discriminate among different sorption sites of micas: With implications for heterogeneous reduction of chromate at the mica-water interface

    Energy Technology Data Exchange (ETDEWEB)

    Ilton, E.S.; Moses, C.O.; Veblen, D.R.

    2000-04-01

    This contribution uses Cr2p and 3p binding energies (BEs) determined by X-ray photoelectron spectroscopy (XPS) to distinguish Cr{sup III} sorbed to different mica sorption sites. The results were used to better understand mechanisms for coupled sorption-reduction of Cr{sub (aq)}{sup VI} by ferrous micas. The research is important because: (1) Cr contamination is a serious and wide spread problem associated with a variety of industries; (2) Micas are important sorbents for Cr because they are ubiquitous, sorb cations and anions over a wide range of pH, and participate in heterogeneous redox reactions via structural Fe{sup II} and FE{sup III}; and (3) The mobility of cations sorbed by micas will depend, in part, on the dominant sorption site. Micas (two biotites, end member phologopite and muscovite) were reacted with Cr{sup III} solutions that contained variable concentrations of NaCl and KCl. Samples were extracted at times intervals and mica edge orientations were analyzed by ZPS. Cr{sub (aq)}{sup III} sorption was greater in Cr{sup III}-NaCl solutions relative to Cr{sup III}-KCl solutions. Cr2p and 3p BEs were bracketed by those for Cr{sup III} in the structure of silicates and in Cr{sup III}-oxyhydroxides. The BE of Cr{sup III} sorbed to micas was higher by about 0.3 eV after reaction with Cr{sup III}-NaCl solutions compared to Cr{sup III}-KCl aqueous solutions. At the experimental conditions, Na{sup +} and K{sup +} differentially block permanent charge sites but not variably charged edge sites of micas. Using the constraints inherent in the experimental design, the authors interpret the difference in CR{sup III} BE between the Cr{sup III}-NaCl and Cr{sup III}-KCl experiments to reflect a change in the dominant sorption site, where high and low Cr BEs indicate Cr sorbed by the interlamellar region and variably charged functional groups at mica edges, respectively. They conclude that small BE shifts for cations sorbed to silicates can be interpreted with

  8. Alpha particle radiography and the track plastic detector CR-39

    International Nuclear Information System (INIS)

    Souza, Bismarck Amilar de.

    1991-05-01

    This work develops the radiographic technique using charged particle beams. This technique complements the X-ray conventional radiography, and presents some advantages in certain cases. The material used as nuclear plastic detector was CR-39, manufactured by Pershre Mould. England, of 250 and 1000 μm nominal thicknesses. The irradiations were made with 7 MeV/Nucleon alpha particles beams, accelerated in the CV-28 Cyclotron of Instituto de Engenharia Nuclear/CNEN - Rio de Janeiro. The etch conditions used were a Na OH 6,25 N solution at 70 0 C, varying the etch time, so that the best etch time was found to be six hours. The calibration curve is presented, which permits images interpretation, showed in terms of light transmittance (obtained using a micro densitometer), and in terms of energy losses suffered by alpha particles in several aluminum degradating thicknesses. This curve was checked by the use of other degradating materials: Mylar, Makrofol, and CR-39 itself. The influence of alpha particle beam FWHM widening on images quality, when it crosses several degradating materials, is also presented. Radiographs of some specimen are presented, including some images obtained varying some irradiation and etch parameters. (author). 62 refs., 22 figs., 19 tabs

  9. Proton radiographic characteristics of thin CR-39 detector

    International Nuclear Information System (INIS)

    Waheed, A.; Manzoor, S.; Khan, H.A.; Urlep, I.; Ilic, R.

    1991-01-01

    Two parameters, track registration sensitivity and densitometric response, were measured in radiography with a low energy (∼4.5 MeV) proton beam and a stack of thin (100μm) CR-39 detector foils. The optimum image quality was obtained at a layer removal thickness of about 1 μm. The image obtained under these conditions is characterized by a high track registration sensitivity (∼60%), high image contrast (the maximum value of the net optical density is ∼0.7) and high spatial resolution (∼1 μm). The application of the technique in biomedicine is illustrated by proton radiographs of botanical samples. (author)

  10. THE ADSORPTION OF Pb(II AND Cr(III BY POLYPROPYLCALIX[4]ARENE POLYMER

    Directory of Open Access Journals (Sweden)

    Suryadi Budi Utomo

    2010-06-01

    Full Text Available A research has been conducted to investigate the adsorption behavior of Pb(II and Cr(III onto polypropylcalix[4]arene polymer. The polypropylcalix[4]arene polymer was synthesized in the presence of H2SO4 catalyst and chloroform under N2 condition for 5 h using 25-allyloxy-26,27,28-trihydroxycalyx[4]arene as the precursor. The Polymer was obtained as yellow crystal with melting point of  288-290 °C and its relative molecular weight was 44.810 g.mol-1. The application of polypropylcalix[4]arene for trapping heavy metal cations and its adsorption model were examined by stirring the suspension of the calixarene in the sample solutions for various pH, time, and concentration of Pb(II and Cr(III solution. Effect of pH on batch experiments for the mentioned ions indicated that the optimum pH for metal binding were 5 for lead(II and chromium(III. The adsorption model of metal ions on polypropylcalix[4]arene followed both the pseudo second order adsorption of Ho's and Langmuir isotherm adsorption kinetics models with rate constant (k were 6.81 x 101 min-1 for Pb(II and 2.64 x 10-2 min-1 for Cr(III. The adsorption equilibrium constant, K, were 5.84 x 105 L.mol-1 for Pb(II and 4.66 x 105 L.mol-1 for Cr(III. The maximum adsorption capacity of polypropylcalix[4]arene to Pb(II and Cr(III were 16.31 and 18.14 mg.g-1 with adsorption energy of 32.90 and 32.34 kJ.mol-1, respectively.   Keywords: polypropylcalix[4]arene, adsorption, Pb(II, and Cr(III

  11. Range to cone length relations for light ions in CR-39

    International Nuclear Information System (INIS)

    Gil, L.R.; Marques, A.

    1988-01-01

    Curves ''range x cone lenght'' and ''diameter x cone lenght'' are calculated for tracks left by low energy light ions in CR-39. The calculations cover ions from helium to iron and are performed for 6.25 N NaOH at 70 0 C and a standard etching time but can be easily extended to other etching conditions. (author) [pt

  12. A quick method for maintaining the molarity of NaOH solution during continuous etching of CR-39

    International Nuclear Information System (INIS)

    Khan, E.U.; Husaini, S.N.; Malik, F.; Sajid, M.; Karim, S.; Qureshi, I.E.

    2002-01-01

    A series of experiments have been performed to investigate the physio-chemical changes that occurred in the 6 M NaOH solution after etching CR-39 (Pershore and Homalite) detectors, each for 3, 6, 9, 12 and 15 h. Various physical parameters like concentration, electrical conductivity (EC) and density of the solutions have been measured after each etching interval. Results have been discussed in the light of stoichiometrical equation for the interaction of CR-39 with NaOH. It is found that the concentration, EC and the density of the solution, in which CR-39 has been etched, increase linearly with respect to the etching time. The inter-relationship of EC-concentration and density-concentration suggest that the concentration of the etchant can be maintained at certain desired value by adjusting the corresponding value of EC or density, measured through non-destructive and quick methods

  13. Investigation of the Effect of He-Ne Laser on the Optical Properties through Etched CN-85 and CR-39 Containing Alpha Tracks

    International Nuclear Information System (INIS)

    Zaki, M.F.; Hegazy, T.M.; Taha, D.H.

    2013-01-01

    The effects of He-Ne laser on the optical characteristics of Cellulose nitrate, CN-85, and Poly allyl diglycole carbonate, CR-39, nuclear track detectors have been studied by using photoluminescence (PL) and UV-visible spectroscopic techniques. The polymers irradiated with alpha particles with close contact to 241 Am and then exposed to He-Ne laser with different doses. The laser energy intensities ranged between 0 and 217 J/cm 2 . The change in the PL spectra may be explained by chain conformational disorders as well as chain scission. From the UV-visible spectra, it is found that a shift in the absorption edge towards a longer wavelength with increasing laser doses can be readily observed. The absorption peak with increasing dose is seen to change into a broad one. The optical band gaps determined from the UV-visible spectra were found to decrease with the increase of energy intensities of He-Ne laser. These results have been explained on the basis of scission of the polymers due to laser irradiation. The UV absorption tail formation in both polymers was related to the diminution of optical band gap. Results show good correlation with the applied doses.

  14. Studying the response of CR-39 to radon in non-polar liquids above water by Monte Carlo simulation and measurement

    International Nuclear Information System (INIS)

    Rezaie, Mohammad Reza; Sohrabi, Mehdi; Negarestani, Ali

    2013-01-01

    The application of CR-39 has been extensive for measurement of radon and progeny in air of dwellings, but limited as regards to measurements of radon in water. In this paper, a new method is introduced for efficient measurement of radon in water by registering alpha particle tracks in a CR-39 detector placed in a non-polar medium such as cyclohexane, hexane and olive oil when each mixed with water, then separated and fixed above water, as a two-phase media. The method introduced here is however different from the widely used liquid - liquid extraction technique by liquid scintillation spectrometry since it is a passive detection method (CR-39) in a non-polar liquid with enhanced absorption of radon in the liquid, it has a capability for long sample counting to decrease the minimum detection limit (MDL), it does not require sophisticated low light counting systems, and it has the potential for simultaneous measurements of large number of samples for large-scale applications. It also has a low cost and is readily available. A new Monte Carlo calculation of energy-distance travelled by alphas from radon and progeny in a medium was also investigated. The sensitivity of CR-39 detector to radon and progeny in water was determined under two conditions; in a single-phase and two-phase media. In a single-phase medium, CR-39 is directly placed either in air, water, cyclohexane, hexane or olive oil. When CR-39 is placed directly in water, its sensitivity is (2.4 ± 0.1) × 10 −4 (track/cm 2 )/(Bq.d/m 3 ). In the two-phase media, CR-39 is placed either in cyclohexane, hexane or olive oil when each is fixed above water. The sensitivities in the two-phase media are significantly enhanced and are respectively (1.98 ± 0.10) × 10 −2 , (2.8 ± 0.15) × 10 −2 and (2.86 ± 0.15) × 10 −2 (track/cm 2 )/(Bq.d/m 3 ). The sensitivies are about 76, 82 and 110 times more than that of when CR-39 is directly placed in water. The new method is a novel alternative for radon

  15. Changes in CR-39 proton sensitivity due to prolonged exposure to high vacuums relevant to the National Ignition Facility and OMEGA.

    Science.gov (United States)

    Manuel, M J-E; Rosenberg, M J; Sinenian, N; Rinderknecht, H; Zylstra, A B; Séguin, F H; Frenje, J; Li, C K; Petrasso, R D

    2011-09-01

    When used at facilities like OMEGA and the NIF, CR-39 is exposed to high vacuum environments before and after irradiation by charged particles and neutrons. Using an electrostatic linear accelerator at MIT, studies have been conducted to investigate the effects of high vacuum exposure on the sensitivity of CR-39 to fusion protons in the ~1-9 MeV energy range. High vacuum conditions, of order 10(-5) Torr, experienced by CR-39 samples at these facilities were emulated. It is shown that vacuum exposure times longer than ~16 h before proton irradiation result in a decrease in proton sensitivity, whereas no effect was observed for up to 67 h of vacuum exposure after proton irradiation. CR-39 sensitivity curves are presented for samples with prolonged exposure to high vacuum before and after proton irradiation. © 2011 American Institute of Physics

  16. Study of projectile fragmentation in the reaction (158 A GeV) Pb + Pb using CR-39

    CERN Document Server

    Qureshi, I E; Javed, M T; Manzoor, S; Sher, G; Aleem, F; Khan, H A

    2005-01-01

    The fragmentation of Pb ions at 158 A GeV energy produced in the interaction with Pb target has been studied using a CR-39 track detector. A stack comprising of 64 detectors was prepared such that a target of 1 cm thickness was sandwiched between the sheets of CR-39. The purpose of this exposure geometry was to calibrate CR-39 with respect to relativistic heavy ions as well as to study the fragmentation of Pb ions at 158 A GeV energy. The exposure was carried out at the SPS beam facility of CERN at normal incidence with a fluence of . Two detectors from the exposed stack have been selected for this study: one before and the other after the target material. After etching, the detectors were scanned using an optical microscope and the etched track lengths and the diameters of the track openings were measured manually. Considering that the lengths of tracks provide the best charge resolution for Z>65, we have measured track lengths for a sufficiently large number of fragments to identify individual charge states...

  17. Characterization of CR 39 nuclear track detector for use as a radon/thoron dosemeter

    International Nuclear Information System (INIS)

    Kandaiya, S.

    1988-02-01

    For the estimation of radon, thoron and their short-lived daughter products in air radon diffusion chambers with passive α-track etch detectors have been used. The report describes the properties of CR 39 track etch detectors in particular with respect to the spectrometric detection of α-particles in the energy range up to 8.77 MeV using chemical and a combination of chemical-electrochemical etching technique. In order to optimize the etching conditions for an α-energy discrimination in the energy range up to 8.77 MeV, the ECE track size diameter and the track density have been investigated as a function of the chemical pre-etching time using three electrical field strengths. In a mixed α-spectrum the contributions of various α-particles with energies between 4.6 to 8.77 MeV have been determined experimentally in CR 39 and compared with the spectral measurement using a surface barrier detector and the same irradiation geometry. Beside CR 39 detectors etched chemically and electrochemically, in addition surface barrier detectors and a Monte Carlo calculation have been used to evaluate the α-energy spectrum for thoron and its daughter products emitted by α-decays in the air volume and the plate-out of daughters at the inner surface on the diffusion chamber. (orig./HP) [de

  18. A fast neutron spectrometer based on an electrochemically etched CR-39 detector with degrader and front radiator

    International Nuclear Information System (INIS)

    Matiullah; Durrani, S.A.

    1987-01-01

    In addition to having promising applications for the development of a fast-neutron dosemeter, electrochemically etched (ECE) CR-39 detectors also offer the possibility of energy-selective fast-neutron detection. This property stems basically from the fact that, to produce 'sparkable' trails in the polymeric detector subjected to ECE, the charged particle resulting from a neutron interaction must fall within a definite 'energy window'. The lower and upper limits of proton energies that can yield ECE spots in CR-39 have been experimentally determined to be ∼ 50 keV and ∼ 2.2 MeV under our processing conditions. To accomplish our objective, we have developed a technique based on ECE spot-density measurements in CR-39 detectors placed in conjuction with judiciously chosen thicknesses of a polyethylene radiator and a lead degrader. The optimum thicknesses of the radiator and the degrader, for a given neutron energy, are determined by computer calculations. (author)

  19. Response of CR-39 Detector Against Fast Neutron Using D-Polyethylene and H-Polyethylene Radiator

    International Nuclear Information System (INIS)

    Sofyan, Hasnel

    1996-01-01

    The research on the response of detector CR-39 by using D-Polyethylene and H-Polyethylene radiator has been carried out. The optimum number of nuclear tracks was found with the use of 30 % NaOH at 80 + 0,5oC for 80 minutes of etching time. The comparison of CR-39 detector response caused by D-Polyethylene radiator against H-Polyethylene radiator of irradiation in air, were found to be 1.18 and 0.84 for 241Am-Be neutron source and neutron source from reactor respectively. For phantom irradiation, the results were found to be 1.75 for 241Am-Be neutron source, and 0.77 for neutron source from reactor

  20. Response of CR39 detector to 5 A GeV Si14+ ions and measurement of total charge changing cross-section

    International Nuclear Information System (INIS)

    Gupta, Renu; Kumar, Ashavani

    2013-01-01

    In the present work, response of CR39 track etch detector was obtained by cone-height measurement technique. CR39 track etch detector was used to identify the incident charged particles and their fragments by the measurements of cone-height of tracks using an optical microscope DM6000 M and automated image analyzer system installed with Leica QWin Plus software. The CR39 detector was calibrated and the response points were fitted with a linear relation and all the points are within the limits of the experimental errors. The charge resolution of the detector was calculated to be 0.2e. The response function is obtained and fitted with a linear relation which is good throughout Z/β=6.1–14.1. The experimental value of the total charge changing cross-section of 5 A GeV Si 14+ ion beam in polyethylene and CR39 combined target is σ tot =(734±128) mb. The total charge changing cross-section is compared with the experimental results of others based on cone base-area measurement technique and also fitted by the Bradt–Peters geometrical cross-section. - Highlights: • Charge resolution of 0.2e was obtained by cone-height measurement. • Consistency in manual measurements of cone-heights is presented. • Response of CR39 detector was obtained and fitted with first degree polynomial. • Total charge changing cross-section of 5 A GeV Si 14+ ions in CH 2 and CR39 as a combined target was calculated

  1. Don Quijote y los eruditos: Sobre una polémica crítica y sus implicaciones metacríticas

    OpenAIRE

    Pardo García, Pedro Javier

    2000-01-01

    [ES]Este trabajo trata sobre Don Quijote y los eruditos: una polémica crítica y sus implicaciones metacríticas. [EN]This paper deals with Don Quixote and scholars: a critical controversy and its implications metacritica.

  2. Development of hybrid track detector using CR39 and photographic plate

    International Nuclear Information System (INIS)

    Kuge, K.; Endo, Y.; Hayashi, K.; Iwakiri, S.; Hasegawa, A.; Yasuda, N.; Kumagai, H.

    2005-01-01

    To improve the hybrid track detector using both CR39 and silver halide photography the gold deposition development technique was applied to this. Nuclear tracks composed of gold clusters were obtained. This method has several advantages; 1. no filament formation, 2. easy control of the cluster size owing to the independence of the size of silver halide grain, 3. easy treatment of the waste solution of developer. (author)

  3. Measurements of radon in dwellings with CR-39 track detectors

    DEFF Research Database (Denmark)

    Majborn, Benny

    1986-01-01

    A passive integrating dosemeter has been designed for measuring natural radiation in dwellings. The dosemeter contains one or two CR-39 track detectors to measure radon and three thermoluminescence dosemeters to measure external radiation. The dosemeter was investigated in a pilot study in 1983....../84, and it is now used in a nationwide survey of natural radiation in Danish dwellings. The characteristics of the dosemeter with respect to radon measurements are presented, and the radon monitoring results obtained in the pilot study are summarized...

  4. Removal of Cr(VI and Toxic Ions from Aqueous Solutions and Tannery Wastewater Using Polymer-Clay Composites

    Directory of Open Access Journals (Sweden)

    Abd El-Azeem Sallam

    2017-10-01

    Full Text Available Polymer-clay composites were prepared by natural zeolite (clinoptilolite or naturally local clay deposits in an N,N-methylene-bis-acrylamide as cross-linked. The resultant composites were used for the removal of Cr(VI from an aqueous solution. Additionally, their effects on soluble ions of tannery wastewater were investigated. The produced composites were characterized using X-ray diffraction (XRD, Fourier transform infrared spectroscopy (FT-IR, and scanning electron microscopy (SEM. The results showed that Cr(VI removal is dependent upon initial concentrations and pH. The adsorption quantity of Cr(VI onto the polymerized clay deposit followed by polymerized zeolite exhibited higher values than their original samples. The polymer-clay composite of clay deposit showed the highest removal of 76.3–100% overall initial concentrations of 10–50 mg L−1 and at initial pH of 2. Kinetics of Cr(VI removal by various sorbents was predicted using a pseudo–second order model. Our findings showed that the levels of salinity and various soluble ions (Cr2+, Na+, Cl− and SO42− in tannery wastewater are very high, and their levels were reduced after treatment, especially by polymerized sorbents. It could be concluded that the polymer-clay composites may be employed as a highly efficient sorbent for the removal of Cr(VI and toxic ions from the wastewater.

  5. Neosporosis epidémica y endémica: descripción de dos eventos en bovinos para cría

    Directory of Open Access Journals (Sweden)

    Patricio M Calandra

    2014-12-01

    Full Text Available El objetivo de este trabajo es describir dos eventos producidos en la provincia de Buenos Aires en los cuales Neospora caninum estuvo asociado a la ocurrencia de abortos en bovinos de cría para carne. En uno de ellos se registraron 11 abortos en 57 vaquillonas durante 45 días, en este evento fue 5 veces más probable que una vaquillona que sufrió un aborto fuera seropositiva a N. caninum que una que no lo sufrió (odds ratio [OR] = 4,9 IC 1,2-19,9 (p 0,05. Se analizaron dos fetos de cada evento: estos resultaron negativos a otros patógenos de la reproducción, aunque presentaron anticuerpos específicos y lesiones histopatológicas compatibles con infecciones por N. caninum. Estos resultados sugieren dos posibles modalidades de presentación de abortos en bovinos causados por N. caninum: una epidémica, como la del primer evento aquí referido, y una endémica, como la del segundo.

  6. Employment of the polycarbonates Makrofol-DE and CR-39 for neutron radiography

    International Nuclear Information System (INIS)

    Pereira, Marco Antonio Stanojev

    2000-01-01

    The track-etch method was employed for Neutron Radiography purposes. The solid state nuclear track detectors Makrofol-DE and CR-39 together with a natural boron converter screen have been used as imaging systems. In order to determine their radiographic characteristics, the imaging systems were irradiated up to neutron exposures around 6x10 10 /cm 2 in a radiography facility installed at the IEA-R1 Nuclear Research Reactor and the detectors developed between 2 and 65 minutes. The main goal of this work was determine the radiography conditions for which the best contrast and resolution are obtained at the image. These conditions are: - Makrofol-DE: neutron exposure between 2x10 9 n/cm 2 and 2x10 10 n/cm 2 and developing time 6 minutes; CR-39: neutron exposure between 3x10 9 n/cm 2 and 2x10 10 n/cm 2 and developing time 25 minutes. The present results were compared with those ones determined to other track detectors, and discussed according to the theory of the image formation in solid state nuclear track detectors based on the optical properties of a single track. (author)

  7. Novel polymer anchored Cr(III) Schiff base complexes: Synthesis, characterization and antimicrobial properties

    Science.gov (United States)

    Selvi, Canan; Nartop, Dilek

    2012-09-01

    New polymer-bound Schiff bases and Cr(III) complexes have been synthesized by the reaction of 4-benzyloxybenzaldehyde, polymer-bound with 2-aminophenol, 2-amino-4-chlorophenol and 2-amino-4-methylphenol. The structure of polymeric-Schiff bases and their Cr(III) complexes have been characterized by elemental analyses, magnetic measurements, IR, UV-Vis, TG-DTA and 1H-NMR. All these compounds have also been investigated for antibacterial activity by the well-diffusion method against Staphylococcus aureus (RSKK-07035), Shigella dysenteria type 10 (RSKK 1036), Listeria monocytogenes 4b(ATCC 19115, Escherichia coli (ATCC 1230), Salmonella typhi H (NCTC 901.8394), Staphylococcus epidermis (ATCC 12228), Brucella abortus (RSKK-03026), Micrococcs luteus (ATCC 93419, Bacillus cereus sp., Pseudomonas putida sp. and for antifungal activity against Candida albicans (Y-1200-NIH).

  8. Effect of oxygen pressure on sensitivity of CR-39 used for astronauts radiation dosimetry

    International Nuclear Information System (INIS)

    Murai, T.; Yabe, S.; Nagamatsu, A.; Tawara, H.; Kumagai, H.; Miyazawa, Y.; Kitajo, K.; Kodaira, S.; Yasuda, N.

    2006-01-01

    The personal radiation dosimeters for astronauts are exposed to low-pressure oxygen gas (0.29 atmospheres) during extra-vehicle activities. CR-39 plastic track detectors are one of the typical passive dosimeters for space radiation monitoring. We investigated change in track formation sensitivity of the antioxidant-doped CR-39 plastic with which oxygen gas comes in contact at different pressures up to 2 atmospheres for 1h to 10 days. The oxygen effect on sensitivity was measured for the C, Si and Fe ions (10-200 keV/μm) from the HIMAC heavy ion accelerator. The sensitivity is obviously sensitive to oxygen pressure at heavy-ion exposures, but not sensitive to the experience of oxygen atmosphere before and after the ion exposures. The maximum sensitivity is obtained at 0.29 atmospheres. The present experimental data suggested that the effect depends on LET of incident particles. (author)

  9. Vacuum treatment of CR-39 for the reduction of background in neutron induced autoradiography of boron

    International Nuclear Information System (INIS)

    Freyer, K.; Treutler, H.C.; Dietze, K.; Hunyadi, I.; Csige, I.; Somogyi, G.

    1991-01-01

    The influence of etching time and vacuum processing before, during, and after neutron irradiation on the ''signal/noise'' ratio of the neutron induced autoradiography of boron using CR-39 track detectors has been investigated. The neutron irradiation was carried out in a vacuum chamber using the Cf-252 neutron source of the Central Institute of Isotope and Radiation Research at Leipzig. Hungarian-made CR-39 type track detectors, MA-ND/p and MA-ND/α, produced in different years, are compared. After a few hours of 2 kPa (about 10 -2 Torr) vacuum treatment, the ''signal/noise'' ratio for boron determination is improved remarkably in most cases of the detector and etching-time combinations used. (author)

  10. Some characteristics of the CR-39 solid state nuclear-track detector for protons and low energy alpha particles

    International Nuclear Information System (INIS)

    Fonseca, E.S. da.

    1983-01-01

    Experimental results related to certain registration properties of the CR-39 solid state nuclear-track detector for charged particles are presented and discussed. The determination of the CR-39 chemical etching in NaOH and KOH solutions, comprising concentration (2-10N) and temperature effects (50-90 0 C), showed the existence of an inverse proportion between the induction time and the temperature as well as the normal concentration of the solutions. The critical energy and the critical energy-loss rate of CR-39 track detectors for registration of protons were experimentally determined. A number of samples was exposed to 24MeV proton beams in the IEN-CNEN Cyclotron (CV-28), using a scattering chamber with a tantalum thin target and aluminium absorbers in contact with the samples in order to provide the required fluctuation in the scattered beam energy. From the mean track-diameter plotted against incident proton energy for 16h and 24h chemical etching (6.25 NaOH, 70 0 C), and considering 1.5 μm as the minimum observable track-diameter, the values (21.0 + - 1.5) MeV and (22.5 + - 1.5) MeV were deduced, respectively, for the critical energy. From the calculated energy-loss rate versus energy curve, the critical energy-loss rate was evaluated as 24 + - 2 MeV.cm 2 /g. Finally, the CR-39 response for low energy alpha particles (E [pt

  11. Environmental dosimetry of radon-222 and daughters: measurement of absolute calibration factors of CR-39 considering the plate-out effects and environmental factors; Dosimetria ambiental de Rn-222 e filhos: medida da eficiencia absoluta do CR-39 levando-se em conta os efeitos do plate-out e fatores ambientais

    Energy Technology Data Exchange (ETDEWEB)

    Paulo, S.R. de

    1991-08-01

    The subject of this work concerns with the measurement of absolute calibration factors for the use of CR-39 as an absolute detector in indoor and daughters monitoring. Up to now the usefulness of calibration factors was restricted to environmental conditions equal (or very close) to those worthing during their determinations. This fact is consequence of the difficulties related to the understanding of the plate-out properties of radon daughters activity in the air. The plate-out effects on radon daughters monitoring performed by SSNTDs are studied. Our experimental results are in agreement with those of other authors about the great sensitivity of CR-39 to the plate-out effects, fact that recommended its use in this work. Being succeeded in the employment of CR-39 as an alpha-spectrometer we concluded that some important information (like the radon daughters deposition rates on the walls of an environment) can be achieved. The knowledge about the behavior of plate-out made possible the determination of the ranges in zenithal angle and energy where CR-39 can detect alpha-particles with efficiency of 100%, at our conditions of track observation. In this way, we obtained calibration factors for CR-39 that are weakly dependent on environmental conditions. We think that these results can contribute to the improvement of RD (Radiation Detector) detection techniques. (author). 159 refs, 106 figs, 05 tabs.

  12. Vacuum treatment of CR-39 for the reduction of background in neutron induced autoradiography of boron

    Energy Technology Data Exchange (ETDEWEB)

    Freyer, K.; Treutler, H.C.; Dietze, K. (Central Inst. of Isotope and Radiation Research, Leipzig (Germany, F.R.)); Hunyadi, I.; Csige, I.; Somogyi, G. (Magyar Tudomanyos Akademia, Debrecen (Hungary). Atommag Kutato Intezete)

    1991-01-01

    The influence of etching time and vacuum processing before, during, and after neutron irradiation on the ''signal/noise'' ratio of the neutron induced autoradiography of boron using CR-39 track detectors has been investigated. The neutron irradiation was carried out in a vacuum chamber using the Cf-252 neutron source of the Central Institute of Isotope and Radiation Research at Leipzig. Hungarian-made CR-39 type track detectors, MA-ND/p and MA-ND/{alpha}, produced in different years, are compared. After a few hours of 2 kPa (about 10{sup -2} Torr) vacuum treatment, the ''signal/noise'' ratio for boron determination is improved remarkably in most cases of the detector and etching-time combinations used. (author).

  13. Effect of various etching conditions on the response of Cr-39 plastic track detector applied for radon dosimetry in environment

    International Nuclear Information System (INIS)

    Maged, A.F.; Ashraf, F.A.

    1997-01-01

    A solid state nuclear track detector Cr-39 has been used for measuring the radon concentration in the soil air and indoor concentration. The bulk etch rate, C B of Cr-39 has been measured in various concentrations of NaOH in the range (6-8 mole) at temperature 70 degree C. In addition, the track etch rate, V T , and the ratio V = V T /V B , of alpha particles emitted from radon gas exists in nature have been measured in a similar range of etching conditions. This study shows that 8 M NaOH at 70 degree C represent the optimum etching conditions for Cr-39, with the range of the present study. The equilibrium factor and gamma-dose equivalent were calculated by using the track densities of open and filtered solid state nuclear track detectors

  14. Annealing effects on the charged particles registration characteristic of the CR-39 traces solid detector

    International Nuclear Information System (INIS)

    Correa, M.M.

    1989-10-01

    CR-39 trace solid detectors samples, previously exposed to alpha particles and fission fragments from a Cf-252 source, were submitted to a annealing treatment to study his effects on the characteristics of charged particle traces registration. (L.C.J.A.)

  15. Status of development in the field of Cr-39 track detectors

    International Nuclear Information System (INIS)

    Somogyi, G.

    1982-01-01

    The present situation concerning the manufacture and etching characteristics of the CR-39 nuclear track detector is surveyed. Especial attention is paid to the trends in research and to the outstanding questions related to the subject. The requirements and procedures in connection with the manufacture of high-quality, thick and thin detector foils are discussed. The main bulk and track etching characteristics are presented, involving the effects of various environmental parameters as well. A statistical account of the typical directions in application is given. (author)

  16. The effect of ArF laser irradiation (193 nm) on the photodegradation and etching properties of alpha-irradiated CR-39 detectors

    Energy Technology Data Exchange (ETDEWEB)

    Shakeri Jooybari, B. [Department of Energy Engineering and Physics, Amirkabir University of Technology, P.O. Box 15875-4413, Tehran, Islamic Republic of Iran (Iran, Islamic Republic of); Nuclear Science and Technology Research Institute (NSRT), Tehran, Islamic Republic of Iran (Iran, Islamic Republic of); Ghergherehchi, M. [College of Information and Technology/ school of Electronic and Electrical Engineering, Sungkyunkwan University, Suwon (Korea, Republic of); Afarideh, H., E-mail: hafarideh@aut.ac.ir [Department of Energy Engineering and Physics, Amirkabir University of Technology, P.O. Box 15875-4413, Tehran, Islamic Republic of Iran (Iran, Islamic Republic of); Lamehi-Rachti, M. [Nuclear Science and Technology Research Institute (NSRT), Tehran, Islamic Republic of Iran (Iran, Islamic Republic of)

    2015-01-01

    The effects of ArF laser irradiation (λ=193nm) at various fluences (energy dose or energy density) on the etching properties of pre-exposed (laser + alpha) CR-39 detectors were studied. First, UV–Vis and Fourier transform infrared (FTIR) spectra were acquired for non-laser-irradiated and laser-irradiated samples to detect the influence of the ArF laser on the chemical modification of the CR-39. Changes observed in the spectra indicated that the predominant process that occurred upon ArF laser irradiation was a bond-scission process. Thereafter, the mean track and bulk etching parameters were experimentally measured in ArF-laser-irradiated CR-39 detectors exposed to an alpha source ({sup 241}Am, E = 5.49 MeV). Inhomogeneous regions in the laser-irradiated side of the CR-39 demonstrated a variable etching rate on only the front side of the CR-39 detector. New equations are also presented for the average bulk etching rate for these inhomogeneous regions (front side). The mean bulk and track etching rates and the mean track dimensions increased in a fluence range of 0–37.03 mJ/cm{sup 2} because of photodegradation and the scission of chemical bonds, which are the predominant processes in this range. When the fluence was increased from 37.03 to 123.45 mJ/cm{sup 2}, the bulk and track etching rates and the track dimensions slowly decreased because of the formation of cross-linked structures on the CR-39 surface. The behavior of the bulk and track etching rates and the track dimensions appears to be proportional to the dose absorbed on the detector surface. It was observed that as the etching time was increased, the bulk and track etching rates and the track dimensions of the laser-irradiated samples decreased because of the shallow penetration depth of the 193 nm laser and the reduction in the oxygen penetration depth.

  17. Calibration of detectors type CR-39 for methodology implementation for Radon-222 determination in CRCN-NE, Brazil; Calibração de detectores do tipo CR-39 para implementação da metodologia de determinação de radônio-222 no CRCN-NE

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Karolayne E.M. da; Santos, Mariana L. de O.; Amaral, Déric S. do; Vilela, Eldice C.; França, Elvis J. de; Hazin, Clovis A.; Farias, Emerson E.G. de, E-mail: keesthefany@gmail.com, E-mail: marianasantos_ufpe@hotmail.com, E-mail: dericsoares@gmail.com, E-mail: ecvilela@cnen.gov.br, E-mail: ejfrana@cnen.gov.br, E-mail: chazin@cnen.gov.br, E-mail: emersonemiliamo@yahoo.com.br [Centro Regional de Ciências Nucleares do Nordeste (CRCN-NE/CNEN-PE), Recife, PE (Brazil)

    2017-07-01

    Radon-222 is a radioactive gas, a product of the decay of uranium-238, which emits alpha particles and represents more than 50% of the dose of natural radiation received by the population. Therefore, monitoring of this gas is essential. For indoor measurement, solid state detectors can be used, the most common of which is CR-39. For monitoring using CR-39, alpha particles, generated by radon-222 and the daughter radionuclides, strike the surface of the detector and generate traces. To relate the trace density per exposure area in environments with unknown activity concentration, it is necessary to determine the calibration factor. The objective of this study was to calibrate CR-39 type detectors for the implementation of the radon determination methodology in Centro Regional de Ciencias Nucleares do Nordeste - CRCN-NE of Brazilian Nuclear Energy Commission - CNEN. In order to determine the CR-39 calibration factor, 19 exposures of the detectors were performed in the CRCN-NE calibration chamber (RN1-CRCN) at an activity of 5.00 kBq m{sup -3}, with the exposure time varying from 24 to 850 hours. For the detection of the detectors, sodium hydroxide was used in a thermostat bath at 90 ° C for 5 hours. The count of number of traits per unit of field was performed with the aid of optical microscopy with an increase of 100 times, being read 30 fields per dosimeters. As a result, the calibration factor was obtained, and the linear response of the trace density as a function of exposure was observed. The results allow the use of CR-39 in the determination of radon-222 by CRCN-NE.

  18. Determination of exhalation rate of radon from walls and indoor radon by CR-39 detectors

    International Nuclear Information System (INIS)

    Vasidov, A.; Tillaev, T.S.

    2007-01-01

    Full text: The knowledge of true value exhalation rate of radon gas from building materials represents scientific and practical interest in environmental radiation protection. This point of view in the paper exhalation rate of radon gas from building materials and a surface of walls with different constructions were determined by detectors CR-39. The values of the exhalation rate of radon per unit area of the granite, concrete, fired and unfired bricks, sand, cement, alabaster varied 0.091 - 0.1 Bq·m -2 ·h -1 . The surface of walls of dwellings constructed from different building materials the exhalation rate of radon are within in limits of 0.083-1.12 Bq·m -2 ·h -1 . Were measurements with CR-39 detectors a level of radon within 50-520 Bq/m 3 in air of rooms constructed of the different building materials

  19. Pershore made CR-39(DOP) as a 1.015 GeV/n 197Au-ion detector

    International Nuclear Information System (INIS)

    Bhattacharyya, D.P.; Chakrabarty, S.; Rakshit, R.; Basu, B.; Pal, P.; Biswas, S.

    1993-01-01

    Pershore made CR-39(DOP) stack was exposed at a zenith angle of 30deg by 197 Au-ions of energy 1.015 GeV/n using LBL BEVALAC beam. The top of the irradiated plate of the stack has been etched in 6.25N NaOH solution at 70degC for one hour. About 1202 cone lengths were optically measured. The estimated etch rate ratio of the incident 197 Au projectile beam in CR-39 has been found to be 27±2. The result has been compared with earlier observation. The charge resolution of the detector has been estimated from the average of double cone lengths and has been found to have a value of (0.58±0.03)e for 197 Au-ions. (orig.)

  20. Paragenesis of Cr-rich muscovite and chlorite in green-mica ...

    Indian Academy of Sciences (India)

    peculiar green colour is attributed to the concen- tration of .... mica quartzite, 1g: white mica (paucity of green mica) with ..... lacking in the white micas. 6.2 Chlorites. Chlorites are associated with green micas in the. Palasgaon–Saigaon area. EPMA analysis of the representative chlorites has been obtained. Cations.

  1. Some characteristics of the CR-39 solid state nuclear - Track Detector for register of protons and low energy alpha particles

    International Nuclear Information System (INIS)

    Fonseca, E.S. da.

    1983-01-01

    Experimental results related to registration properties of the CR-39 Solid State Nuclear Track Detector for charged particles are presented and discussed. The existence of an inverse proportion between the induction time and the temperature as well as normal concentration of solutions, is showed by the study of CR-39 chemical etching characteristics in NaOH and KOH solutions, comprising varied concentration and temperature. The bulk-etch rate and activation energy of the process were obtained. The critical energy and critical energy-loss rate of CR-39 track-detectors for registration of protons were experimentally determined. Samples were exposed to 24 Mev proton beams in the IEN/CNEN Cyclotron (CV-28), using scattering chamber with a tantalum thin target and aluminium absorbers in contact with the samples, in order to provide the required fluctuation in the scattered beam energy. From the mean track-diameter plotted against incident proton energy the critical energy was obtained. From the calculated energy-loss rate vs. energy curve, the critical energy loss rate were evaluated. The CR-39 response for low energy alpha particles (E = 7h) under the conditions of 6.25 N NaOH at 70 0 C. It is shown that successive chemical etchings do not produce the same track geometry as obtained by means of a continous revelation with the same total etching time. (Author) [pt

  2. Environmental dosimetry of radon-222 and daughters: measurement of absolute calibration factors of CR-39 considering the plate-out effects and environmental factors

    International Nuclear Information System (INIS)

    Paulo, S.R. de.

    1991-08-01

    The subject of this work concerns with the measurement of absolute calibration factors for the use of CR-39 as an absolute detector in indoor and daughters monitoring. Up to now the usefulness of calibration factors was restricted to environmental conditions equal (or very close) to those worthing during their determinations. This fact is consequence of the difficulties related to the understanding of the plate-out properties of radon daughters activity in the air. The plate-out effects on radon daughters monitoring performed by SSNTDs are studied. Our experimental results are in agreement with those of other authors about the great sensitivity of CR-39 to the plate-out effects, fact that recommended its use in this work. Being succeeded in the employment of CR-39 as an alpha-spectrometer we concluded that some important information (like the radon daughters deposition rates on the walls of an environment) can be achieved. The knowledge about the behavior of plate-out made possible the determination of the ranges in zenithal angle and energy where CR-39 can detect alpha-particles with efficiency of 100%, at our conditions of track observation. In this way, we obtained calibration factors for CR-39 that are weakly dependent on environmental conditions. We think that these results can contribute to the improvement of RD (Radiation Detector) detection techniques. (author). 159 refs, 106 figs, 05 tabs

  3. A parameterization of nuclear track profiles in CR-39 detector

    Science.gov (United States)

    Azooz, A. A.; Al-Nia'emi, S. H.; Al-Jubbori, M. A.

    2012-11-01

    In this work, the empirical parameterization describing the alpha particles’ track depth in CR-39 detectors is extended to describe longitudinal track profiles against etching time for protons and alpha particles. MATLAB based software is developed for this purpose. The software calculates and plots the depth, diameter, range, residual range, saturation time, and etch rate versus etching time. The software predictions are compared with other experimental data and with results of calculations using the original software, TRACK_TEST, developed for alpha track calculations. The software related to this work is freely downloadable and performs calculations for protons in addition to alpha particles. Program summary Program title: CR39 Catalog identifier: AENA_v1_0 Program summary URL:http://cpc.cs.qub.ac.uk/summaries/AENA_v1_0.html Program obtainable from: CPC Program Library, Queen’s University, Belfast, N. Ireland Licensing provisions: Copyright (c) 2011, Aasim Azooz Redistribution and use in source and binary forms, with or without modification, are permitted provided that the following conditions are met • Redistributions of source code must retain the above copyright, this list of conditions and the following disclaimer. • Redistributions in binary form must reproduce the above copyright notice, this list of conditions and the following disclaimer in the documentation and/or other materials provided with the distribution This software is provided by the copyright holders and contributors “as is” and any express or implied warranties, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose are disclaimed. In no event shall the copyright owner or contributors be liable for any direct, indirect, incidental, special, exemplary, or consequential damages (including, but not limited to, procurement of substitute goods or services; loss of use, data, or profits; or business interruption) however caused and

  4. Effect of argon ion implantation on the electrical and dielectric properties of CR-39

    International Nuclear Information System (INIS)

    Chawla, Mahak; Shekhawat, Nidhi; Goyal, Meetika; Gupta, Divya; Sharma, Annu; Aggarwal, Sanjeev

    2016-01-01

    The objective of the present work is to study the effect of 130 keV Ar"+ ions on the electrical and dielectric properties of CR-39 samples at various doses 5×10"1"4, 1×10"1"5 and 1×10"1"6 Ar"+ cm"−"2. Current-Voltage (I-V characteristics) measurements have been used to study the electrical properties of virgin and Ar"+ implanted CR-39 specimens. The current has been found to be increased with increasing voltage as well as with increasing ion dose. The dielectric spectroscopy of these specimens has been done in the frequency range of 100 kHz-100 MHz. The dielectric constant has been found to be decreasing whereas dielectric loss factor increases with increasing ion fluence. These kind of behavior observed in the implanted specimens indicate towards the formation of carbonaceous clusters due to the cross linking, chemical bond cleavage, formation of free radicals. The changes observed in the dielectric behavior have been further correlated with the structural changes observed through I-V characteristics.

  5. Long-term measurements of equilibrium factor with electrochemically etched CR-39 SSNTD

    International Nuclear Information System (INIS)

    Ng, F.M.F.; Nikezic, D.; Yu, K.N.

    2007-01-01

    Recently, our group proposed a method (proxy equilibrium factor method) using a bare LR 115 detector for long-term monitoring of the equilibrium factor. Due to the presence of an upper alpha-particle energy threshold for track formation in the LR 115 detector, the partial sensitivities to 222 Rn, 218 Po and 214 Po were the same, which made possible measurements of a proxy equilibrium factor F p that was well correlated with the equilibrium factor. In the present work, the method is extended to CR-39 detectors which have better-controlled etching properties but do not have an upper energy threshold. An exposed bare CR-39 detector is first pre-etched in 6.25 N NaOH solution at 70 o C for 6 h, and then etched electrochemically in a 6.25 N NaOH solution with ac voltage of 400 V (peak to peak) and 5 kHz applied across the detectors for 1 h at room temperature. Under these conditions, for tracks corresponding to incident angles larger than or equal to 50 deg., the treeing efficiency is 0% and 100% for incident energies smaller than and larger than 4 MeV, respectively. A simple method is then proposed to obtain the total number of tracks formed below the upper energy threshold of 4 MeV, from which the proxy equilibrium factor method can apply

  6. Calibrations of CR39 and Makrofol nuclear track detectors and search for exotic particles

    CERN Document Server

    Ambrosio, M; Auriemma, G; Bakari, D; Baldini, A; Barbarino, G C; Barish, B C; Battistoni, G; Becherini, Y; Bellotti, R; Bemporad, C; Bernardini, P; Bilokon, H; Bloise, C; Bower, C; Brigida, M; Bussino, S; Cafagna, F; Calicchio, M; Campana, D; Carboni, M; Caruso, R; Cecchini, S; Cei, F; Chiarella, V; Chiarusi, T; Choudhary, B C; Coutu, S; Cozzi, M; De Cataldo, G; De Marzo, C; De Mitri, I; De Vincenzi, M; Dekhissi, H; Derkaoui, J; Di Credico, A; Erriquez, O; Favuzzi, C; Forti, C; Fusco, P; Giacomelli, G; Giannini, G; Giglietto, N; Giorgini, M; Grassi, M; Grillo, A; Guarino, F; Gustavino, C; Habig, A; Hanson, K; Heinz, R; Iarocci, E; Katsavounidis, E; Katsavounidis, I; Kearns, E; Kim, H; Kumar, A; Kyriazopoulou, S; Lamanna, E; Lane, C; Levin, D S; Lipari, P; Longley, N P; Longo, M J; Loparco, F; Maaroufi, F; Mancarella, G; Mandrioli, G; Manzoor, S; Margiotta, A; Marini, A; Martello, D; Marzari-Chiesa, A; Matteuzzi, D; Mazziotta, M N; Michael, D G; Monacelli, P; Montaruli, T; Monteno, M; Mufson, S; Musser, J; Nicolò, D; Nolty, R; Orth, C; Osteria, G; Palamara, O; Patera, V; Patrizii, L; Pazzi, R; Peck, C W; Perrone, L; Petrera, S; Pistilli, P; Popa, V; Rainó, A; Reynoldson, J; Ronga, F; Rrhioua, A; Satriano, C; Scapparone, E; Scholberg, K; Sciubba, A; Serra, P; Sioli, M; Sirri, G; Sitta, M; Spinelli, P; Spinetti, M; Spurio, M; Steinberg, R; Stone, J L; Sulak, L R; Surdo, A; Tarle, G; Togo, V; Vakili, M; Walter, C W; Webb, R; 10.1016/S0920-5632(03)02249-7

    2003-01-01

    We present the final results of the search for exotic massive particles in the cosmic radiation performed with the MACRO underground experiment. Magnetic monopoles and nuclearites flux upper limits obtained with the CR39 nuclear track subdetector, the scintillation and streamer tube subdetectors are given. Searches at high altitude with the SLIM experiment are in progress.

  7. The use of CH3OH additive to NaOH for etching alpha particle tracks in a CR-39 plastic nuclear track detector

    International Nuclear Information System (INIS)

    Ashry, A.H.; Abdalla, A.M.; Rammah, Y.S.; Eisa, M.; Ashraf, O.

    2014-01-01

    Fast detection of alpha particles in CR-39 detectors was investigated using a new chemical etchant. 252 Cf and 241 Am sources were used for irradiating samples of CR-39 SSNTDs with fission fragments and alpha particles in air at normal temperature and pressure. A series of experimental chemical etching are carried out using new etching solution (8 ml of 10N NaOH+1 ml CH 3 OH) at 60 °C to detect alpha particle in short time in CR-39 detectors. Suitable analyzing software has been used to analyze experimental data. From fission and alpha track diameters, the value of bulk etching rate is equal to 2.73 μm/h. Both the sensitivity and etching efficiency were found to vary with the amount of methanol in the etching solution. Pure NaOH was used as a control to compare with the result from etching in NaOH with different concentrations of CH 3 OH. The etching efficiency is determined and compared with conventional aqueous solution of 6.25N NaOH at 70 °C for etching time equals 5 h. In this study, the obtained etching efficiency shows a considerable agreement with the previous work. - Highlights: • The value of bulk etching rate is equal to 2.73 μm/h. • Fast detection of alpha particles in CR-39 detectors. • Samples of CR-39 have been irradiated with fission fragments. • Etching efficiency was determined

  8. Effects of high neutron doses and duration of the chemical etching on the optical properties of CR-39

    International Nuclear Information System (INIS)

    Sahoo, G.S.; Tripathy, S.P.; Paul, S.; Sharma, S.C.; Joshi, D.S.; Gupta, A.K.; Bandyopadhyay, T.

    2015-01-01

    Effects of the duration of chemical etching on the transmittance, absorbance and optical band gap width of the CR-39 (Polyallyl diglycol carbonate) detectors irradiated to high neutron doses (12.7, 22.1, 36.0 and 43.5 Sv) were studied. The neutrons were produced by bombardment of a thick Be target with 12 MeV protons of different fluences. The unirradiated and neutron-irradiated CR-39 detectors were subjected to a stepwise chemical etching at 1 h intervals. After each step, the transmission spectra of the detectors were recorded in the range from 200 to 900 nm, and the absorbances and optical band gap widths were determined. The effect of the etching on the light transmittance of unirradiated detectors was insignificant, whereas it was very significant in the case of the irradiated detectors. The dependence of the optical absorbance on the neutron dose is linear at short etching periods, but exponential at longer ones. The optical band gap narrows with increasing etching time. It is more significant for the irradiated dosimeters than for the unirradiated ones. The rate of the narrowing of the optical band gap with increasing neutron dose increases with increasing duration of the etching. - Highlights: • The variation of optical properties of CR-39 at very high neutron dose is analyzed. Etching process is found to play a crucial role for change in optical properties of neutron-irradiated CR-39. • The optical absorbance varies linearly at lower dose, at very high dose absorbance saturation occurs. The dose at which saturation absorbance is observed shifts towards lower neutron dose with increase in etching time. • The rate of decrease in optical band gap with respect to neutron dose is found to be more at higher etching durations

  9. The development of an automatic scanning method for CR-39 neutron dosimeter

    International Nuclear Information System (INIS)

    Tawara, Hiroko; Miyajima, Mitsuhiro; Sasaki, Shin-ichi; Hozumi, Ken-ichi

    1989-01-01

    A method of measuring low level neutron dose has been developed with CR-39 track detectors using an automatic scanning system. It is composed of the optical microscope with a video camera, an image processor and a personal computer. The focus point of the microscope and the X-Y stage are controlled from the computer. The minimum detectable neutron dose is estimated at 4.6 mrem in the uniform field of neutron with equivalent energy spectrum to Am-Be source from the results of automatic measurements. (author)

  10. Alpha activity of 190 Pt isotope measured with CR-39 track detector

    International Nuclear Information System (INIS)

    Tavares, O.A.P.; Terranova, M.L.

    1996-11-01

    A new method to measure alpha activity of long-lived radioisotopes is reported. The method consists basically in using CR-39 track detectors in close contact with thick samples of the radioelement to be investigated. Accordingly, a long-term exposure experiment has been performed using metallic sheets of natural platinum to measure alpha activity of platinum 190 isotope. The half-life of platinum 190 has been obtained in good agreement with two recent theoretical half-life predictions. (author). 21 refs., 3 figs., 2 tabs

  11. Empirical assessment of the detection efficiency of CR-39 at high proton fluence and a compact, proton detector for high-fluence applications

    Energy Technology Data Exchange (ETDEWEB)

    Rosenberg, M. J., E-mail: mrosenbe@mit.edu; Séguin, F. H.; Waugh, C. J.; Rinderknecht, H. G.; Orozco, D.; Frenje, J. A.; Johnson, M. Gatu; Sio, H.; Zylstra, A. B.; Sinenian, N.; Li, C. K.; Petrasso, R. D. [Plasma Science and Fusion Center, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139 (United States); Glebov, V. Yu.; Stoeckl, C.; Hohenberger, M.; Sangster, T. C. [Laboratory for Laser Energetics, University of Rochester, Rochester, New York 14623 (United States); LePape, S.; Mackinnon, A. J.; Bionta, R. M.; Landen, O. L. [Lawrence Livermore National Laboratory, Livermore, California 94550 (United States); and others

    2014-04-15

    CR-39 solid-state nuclear track detectors are widely used in physics and in many inertial confinement fusion (ICF) experiments, and under ideal conditions these detectors have 100% detection efficiency for ∼0.5–8 MeV protons. When the fluence of incident particles becomes too high, overlap of particle tracks leads to under-counting at typical processing conditions (5 h etch in 6N NaOH at 80 °C). Short etch times required to avoid overlap can cause under-counting as well, as tracks are not fully developed. Experiments have determined the minimum etch times for 100% detection of 1.7–4.3-MeV protons and established that for 2.4-MeV protons, relevant for detection of DD protons, the maximum fluence that can be detected using normal processing techniques is ≲3 × 10{sup 6} cm{sup −2}. A CR-39-based proton detector has been developed to mitigate issues related to high particle fluences on ICF facilities. Using a pinhole and scattering foil several mm in front of the CR-39, proton fluences at the CR-39 are reduced by more than a factor of ∼50, increasing the operating yield upper limit by a comparable amount.

  12. Regular self-microstructuring on CR39 using high UV laser dose

    International Nuclear Information System (INIS)

    Parvin, P.; Refahizadeh, M.; Mortazavi, S.Z.; Silakhori, K.; Mahdiloo, A.; Aghaii, P.

    2014-01-01

    The UV laser induced replicas in the form of self-lining microstructures are created by high dose (with high fluence) ArF laser irradiation on CR39. Microstructures as the self-induced contours, in the form of concentric circles, appear when the laser fluence is well above the ablation threshold. It leads to the regular periodic parallel lines, i.e. circles with large radii having spatial separation 100–200 nm and line width 300–600 nm, where the number of shots increases to achieve higher UV doses. The surface wettability is also investigated after laser texturing to exhibit that a notable hydrophilicity takes place at high doses.

  13. Particularisation of Alpha Contamination using CR-39 Track Detectors

    International Nuclear Information System (INIS)

    Zakia, M.F.; El-Shaer, Y.H.

    2008-01-01

    Solid-state nuclear track detectors have found wide use in various domains of science and technology, e.g. in environmental experiments. The measurement of alpha activity on sources in an environment, such as air is not easy because of short penetration range of the alpha particles. Furthermore, the measurement of alpha activity by most gas ionization detectors suffers from the high background induced by the accompanying gamma radiation. Solid State Nuclear Track Detectors (SSNTDs) have been used successfully as detecting devices as passive system to detect the alpha contamination different surfaces. This work presents the response of CR-39 (for two types) to alpha particles from two sources, 238 Pu with energy 5 MeV and 241 Am with energy 5.4 MeV. The methods of etching and counting are investigated, along with the achievable linearity, efficiency and reproducibility. The sensitivity to low activity and energy resolution are studied

  14. Testing Novel CR-39 Detector Deployment System For Identification of Subsurface Fractures, Soda Springs, ID

    Energy Technology Data Exchange (ETDEWEB)

    McLing, Travis [Idaho National Lab. (INL), Idaho Falls, ID (United States); Carpenter, Michael [Idaho National Lab. (INL), Idaho Falls, ID (United States); Brandon, William [Idaho National Lab. (INL), Idaho Falls, ID (United States); Zavala, Bernie [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2015-06-01

    The Environmental Protection Agency (EPA) has teamed with Battelle Energy Alliance, LLC (BEA) at Idaho National Laboratory (INL) to facilitate further testing of geologic-fracture-identification methodology at a field site near the Monsanto Superfund Site located in Soda Springs, Idaho. INL has the necessary testing and technological expertise to perform this work. Battelle Memorial Institute (BMI) has engaged INL to perform this work through a Work for Others (WFO) Agreement. This study continues a multi-year collaborative effort between INL and EPA to test the efficacy of using field deployed Cr-39 radon in soil portals. This research enables identification of active fractures capable of transporting contaminants at sites where fractures are suspected pathways into the subsurface. Current state of the art methods for mapping fracture networks are exceedingly expensive and notoriously inaccurate. The proposed WFO will evaluate the applicability of using cheap, readily available, passive radon detectors to identify conductive geologic structures (i.e. fractures, and fracture networks) in the subsurface that control the transport of contaminants at fracture-dominated sites. The proposed WFO utilizes proven off-the-shelf technology in the form of CR-39 radon detectors, which have been widely deployed to detect radon levels in homes and businesses. In an existing collaborative EPA/INL study outside of this workscope,. CR-39 detectors are being utilized to determine the location of active transport fractures in a fractured granitic upland adjacent to a landfill site at the Fort Devens, MA that EPA-designated as National Priorities List (NPL) site. The innovative concept of using an easily deployed port that allows the CR-39 to measure the Rn-222 in the soil or alluvium above the fractured rock, while restricting atmospheric Rn-222 and soil sourced Ra from contaminating the detector is unique to INL and EPA approach previously developed. By deploying a series of these

  15. A novel method to recover DD fusion proton CR-39 data corrupted by fast ablator ions at OMEGA and the National Ignition Facility

    Energy Technology Data Exchange (ETDEWEB)

    Sutcliffe, G. D., E-mail: gdsut@mit.edu; Milanese, L. M.; Orozco, D.; Lahmann, B.; Gatu Johnson, M.; Séguin, F. H.; Sio, H.; Frenje, J. A.; Li, C. K.; Petrasso, R. D. [Plasma Science and Fusion Center, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139 (United States); Park, H.-S.; Rygg, J. R.; Casey, D. T.; Bionta, R.; Turnbull, D. P.; Huntington, C. M.; Ross, J. S. [Lawrence Livermore National Laboratory, Livermore, California 94550 (United States); Zylstra, A. B. [Los Alamos National Laboratory, Los Alamos, New Mexico 87545 (United States); Rosenberg, M. J.; Glebov, V. Yu. [Laboratory for Laser Energetics, Rochester, New York 14623 (United States)

    2016-11-15

    CR-39 detectors are used routinely in inertial confinement fusion (ICF) experiments as a part of nuclear diagnostics. CR-39 is filtered to stop fast ablator ions which have been accelerated from an ICF implosion due to electric fields caused by laser-plasma interactions. In some experiments, the filtering is insufficient to block these ions and the fusion-product signal tracks are lost in the large background of accelerated ion tracks. A technique for recovering signal in these scenarios has been developed, tested, and implemented successfully. The technique involves removing material from the surface of the CR-39 to a depth beyond the endpoint of the ablator ion tracks. The technique preserves signal magnitude (yield) as well as structure in radiograph images. The technique is effective when signal particle range is at least 10 μm deeper than the necessary bulk material removal.

  16. A novel method to recover DD fusion proton CR-39 data corrupted by fast ablator ions at OMEGA and the National Ignition Facility

    International Nuclear Information System (INIS)

    Sutcliffe, G. D.; Milanese, L. M.; Orozco, D.; Lahmann, B.; Gatu Johnson, M.; Séguin, F. H.; Sio, H.; Frenje, J. A.; Li, C. K.; Petrasso, R. D.; Park, H.-S.; Rygg, J. R.; Casey, D. T.; Bionta, R.; Turnbull, D. P.; Huntington, C. M.; Ross, J. S.; Zylstra, A. B.; Rosenberg, M. J.; Glebov, V. Yu.

    2016-01-01

    CR-39 detectors are used routinely in inertial confinement fusion (ICF) experiments as a part of nuclear diagnostics. CR-39 is filtered to stop fast ablator ions which have been accelerated from an ICF implosion due to electric fields caused by laser-plasma interactions. In some experiments, the filtering is insufficient to block these ions and the fusion-product signal tracks are lost in the large background of accelerated ion tracks. A technique for recovering signal in these scenarios has been developed, tested, and implemented successfully. The technique involves removing material from the surface of the CR-39 to a depth beyond the endpoint of the ablator ion tracks. The technique preserves signal magnitude (yield) as well as structure in radiograph images. The technique is effective when signal particle range is at least 10 μm deeper than the necessary bulk material removal.

  17. A novel method to recover DD fusion proton CR-39 data corrupted by fast ablator ions at OMEGA and the National Ignition Facility

    Energy Technology Data Exchange (ETDEWEB)

    Sutcliffe, G. D. [Plasma Science and Fusion Center, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, USA; Milanese, L. M. [Plasma Science and Fusion Center, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, USA; Orozco, D. [Plasma Science and Fusion Center, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, USA; Lahmann, B. [Plasma Science and Fusion Center, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, USA; Gatu Johnson, M. [Plasma Science and Fusion Center, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, USA; Séguin, F. H. [Plasma Science and Fusion Center, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, USA; Sio, H. [Plasma Science and Fusion Center, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, USA; Frenje, J. A. [Plasma Science and Fusion Center, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, USA; Li, C. K. [Plasma Science and Fusion Center, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, USA; Petrasso, R. D. [Plasma Science and Fusion Center, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, USA; Park, H. -S. [Lawrence Livermore National Laboratory, Livermore, California 94550, USA; Rygg, J. R. [Lawrence Livermore National Laboratory, Livermore, California 94550, USA; Casey, D. T. [Lawrence Livermore National Laboratory, Livermore, California 94550, USA; Bionta, R. [Lawrence Livermore National Laboratory, Livermore, California 94550, USA; Turnbull, D. P. [Lawrence Livermore National Laboratory, Livermore, California 94550, USA; Huntington, C. M. [Lawrence Livermore National Laboratory, Livermore, California 94550, USA; Ross, J. S. [Lawrence Livermore National Laboratory, Livermore, California 94550, USA; Zylstra, A. B. [Los Alamos National Laboratory, Los Alamos, New Mexico 87545, USA; Rosenberg, M. J. [Laboratory for Laser Energetics, Rochester, New York 14623, USA; Glebov, V. Yu. [Laboratory for Laser Energetics, Rochester, New York 14623, USA

    2016-08-05

    CR-39 detectors are used routinely in inertial confinement fusion (ICF) experiments as a part of nuclear diagnostics. CR-39 is filtered to stop fast ablator ions which have been accelerated from an ICF implosion due to electric fields caused by laser-plasma interactions. In some experiments, the filtering is insufficient to block these ions and the fusion-product signal tracks are lost in the large background of accelerated ion tracks. A technique for recovering signal in these scenarios has been developed, tested, and implemented successfully. The technique involves removing material from the surface of the CR-39 to a depth beyond the endpoint of the ablator ion tracks. The technique preserves signal magnitude (yield) as well as structure in radiograph images. The technique is effective when signal particle range is at least 10 μm deeper than the necessary bulk material removal.

  18. Alpha-particle autoradiography in CR-39: a technique for quantitative assessment of alpha-emitters in biological tissue

    International Nuclear Information System (INIS)

    Fews, A.P.; Henshaw, D.L.

    1983-01-01

    The techniques for α-particle autoradiography based on the plastic nuclear track detector CR-39, previously reported, have been developed considerably. The techniques are applied to α-autoradiography of human lung tissue in particular but are applicable to any biological tissue. The most important developments are: (i) Improvements in the manufacture and pre-etching of the plastic. (ii) High resolution α-particle spectroscopy in CR-39 plastic based on the analysis of the structure of the etched track. (iii) Calculation of the effective thickness of tissue sampled by the plastic. (iv) A deconvolution analysis which takes the distributions of track length and dip angle in the plastic and determines the α-particle range spectrum and distribution of tissue activity with height above the plastic surface. (v) The analysis of radon diffusion in tissue to determine the mean radon diffusion distance in tissue and plastic. (author)

  19. Synthesis of non-toxic As and Cr nanoparticles through redox activity of highly flexible layered coordination polymer of Ni(II)

    Science.gov (United States)

    Agarwal, Rashmi A.

    2018-03-01

    A simple method for the sequestration of As(III) and Cr(VI) from water has been demonstrated by utilizing a highly flexible porous coordination polymer (PCP) of Ni(II) in its as synthesized form or without solvent removal. This PCP reduces the high toxicity of As(III) and Cr(VI) ions into non-toxic As(0) and Cr/Cr2O3/CrO2 (zero, tri and tetravalent) nanoparticles (NPs) within its pores, and this is characterized by powder x-ray diffraction, x-ray photoelectron spectroscopy and high-resolution transmission electron microscopy analysis. The high functionality of this polymer is due to the presence of monodentate carboxylate groups of a benzenetricarboxylate linker, which provide anchoring sites to the metal ions of the metal precursors. Due to the highly oxidising nature of these toxic ions, a redox reaction takes place between the framework metal ions and toxic metal ions, which is explained by an electron paramagnetic resonance study. This is the first report to synthesize non-toxic, as well as useful, NPs of As and Cr from their highly toxic ions within the cavities of a PCP for remediation of the toxic waste stream and contaminated waste water.

  20. Synthesis of non-toxic As and Cr nanoparticles through redox activity of highly flexible layered coordination polymer of Ni(II).

    Science.gov (United States)

    Agarwal, Rashmi A

    2018-03-09

    A simple method for the sequestration of As(III) and Cr(VI) from water has been demonstrated by utilizing a highly flexible porous coordination polymer (PCP) of Ni(II) in its as synthesized form or without solvent removal. This PCP reduces the high toxicity of As(III) and Cr(VI) ions into non-toxic As(0) and Cr/Cr 2 O 3 /CrO 2 (zero, tri and tetravalent) nanoparticles (NPs) within its pores, and this is characterized by powder x-ray diffraction, x-ray photoelectron spectroscopy and high-resolution transmission electron microscopy analysis. The high functionality of this polymer is due to the presence of monodentate carboxylate groups of a benzenetricarboxylate linker, which provide anchoring sites to the metal ions of the metal precursors. Due to the highly oxidising nature of these toxic ions, a redox reaction takes place between the framework metal ions and toxic metal ions, which is explained by an electron paramagnetic resonance study. This is the first report to synthesize non-toxic, as well as useful, NPs of As and Cr from their highly toxic ions within the cavities of a PCP for remediation of the toxic waste stream and contaminated waste water.

  1. Study of the pore-opening process of latent tracks of light low-energetic ions in CR-39 by means of electrolytic etching

    International Nuclear Information System (INIS)

    Oganesyan, V.R.

    2005-01-01

    In this thesis the irradiation of 10-μm thick CR-39 foils with 5.5-7 MeV protons and of 22-400 μm thick CR-39 foils with 4.85-28 MeV α-particles with subsequent determination of the etching velocities is described. By means of scanning electron microscopy (SEM) the pore shape after irradiation was determined. From the analysis of the track profiles by means of SEM the track-nucleus diameter for 28 MeV α particles was determined to 1.4 nm. (HSI)

  2. Charge resolution of a Hungarian brand CR-39(MA-ND) detector exposed to a 84Kr beam of energy 0.45A GeV

    International Nuclear Information System (INIS)

    Bhattacharyya, D.P.; Basu, B.; Pal, P.; Mukherjee, S.C.; Ganguly, A.K.; Hunyady, I.

    1990-01-01

    The Hungarian brand CR-39(MA-ND) plastic has been irradiated with a 84 Kr ion beam of energy 0.45A GeV and etched for four different etching times, viz. 4, 6, 8 and 12 h. The estimated charge resolution of a CR-39(MA-ND) detector for registering the nuclei 32 ≤ Z ≤ 36 was found to be 0.18e which is close to our previous observation of the response with a CR-39(DOP) Pershore made plate exposed to a 1.88A GeV 56 Fe beam at the Lawrence Berkeley Laboratory's Bevalac. It was found that the estimated etch rate ratio V T /V G is independent of etching time. The cone length and minor axis of the etch pits has been found to increase with etching time. (orig.)

  3. Measuring depths of sub-micron tracks in a CR-39 detector from replicas using Atomic Force Microscopy

    International Nuclear Information System (INIS)

    Yu, K.N.; Ng, F.M.F.; Nikezic, D.

    2005-01-01

    One of the challenging tasks in the application of solid-state nuclear track detectors (SSNTDs) is the measurement of the depth of the tracks, in particular, the shallow ones resulting from short etching periods. In the present work, a method is proposed to prepare replicas of tracks from α particles in the CR-39 SSNTDs and to measure their heights using atomic force microscopy (AFM). After irradiation, the detectors were etched in a 6.25N aqueous solution of NaOH maintained at 70 deg. C. The etched detectors were immersed into a beaker of the replicating fluid, which was placed in a water bath under ultrasonic vibration and maintained at room temperature to facilitate the filling of the etched tracks with the replicating fluid. As an example of application, these results have been used to derive a V function for the CR-39 detectors used in the present study (for the specified etching conditions)

  4. 166. Anuloplastia con anillo Carpentier-McCarthy-Adams IMR ETlogix® en la insuficiencia mitral isquémica crónica. Resultados a medio plazo

    Directory of Open Access Journals (Sweden)

    C.E. Martín López

    2010-01-01

    Conclusiones: La anuloplastia con anillo Carpentier-Mc-Carthy-Adams IMR ETlogix® en la insuficiencia mitral isquémica crónica presenta unos aceptables resultados a medio plazo, con una corrección efectiva y durable de la insuficiencia mitral.

  5. Application of combined TLD and CR-39 PNTD method for measurement of total dose and dose equivalent on ISS

    International Nuclear Information System (INIS)

    Benton, E.R.; Deme, S.; Apathy, I.

    2006-01-01

    To date, no single passive detector has been found that measures dose equivalent from ionizing radiation exposure in low-Earth orbit. We have developed the I.S.S. Passive Dosimetry System (P.D.S.), utilizing a combination of TLD in the form of the self-contained Pille TLD system and stacks of CR-39 plastic nuclear track detector (P.N.T.D.) oriented in three mutually orthogonal directions, to measure total dose and dose equivalent aboard the International Space Station (I.S.S.). The Pille TLD system, consisting on an on board reader and a large number of Ca 2 SO 4 :Dy TLD cells, is used to measure absorbed dose. The Pille TLD cells are read out and annealed by the I.S.S. crew on orbit, such that dose information for any time period or condition, e.g. for E.V.A. or following a solar particle event, is immediately available. Near-tissue equivalent CR-39 P.N.T.D. provides Let spectrum, dose, and dose equivalent from charged particles of LET ∞ H 2 O ≥ 10 keV/μm, including the secondaries produced in interactions with high-energy neutrons. Dose information from CR-39 P.N.T.D. is used to correct the absorbed dose component ≥ 10 keV/μm measured in TLD to obtain total dose. Dose equivalent from CR-39 P.N.T.D. is combined with the dose component <10 keV/μm measured in TLD to obtain total dose equivalent. Dose rates ranging from 165 to 250 μGy/day and dose equivalent rates ranging from 340 to 450 μSv/day were measured aboard I.S.S. during the Expedition 2 mission in 2001. Results from the P.D.S. are consistent with those from other passive detectors tested as part of the ground-based I.C.C.H.I.B.A.N. intercomparison of space radiation dosimeters. (authors)

  6. Fast neutron spectrometry based on proton detection in CR-39 detector

    Energy Technology Data Exchange (ETDEWEB)

    Dajko, G.; Somogyi, G.

    1986-01-01

    The authors have developed a home-made proton-sensitive CR-39 track detector called MA-ND/p. Using this and the n-p scattering process the performance of a fast neutron spectrometer has been studied by applying two different methods. These are based on track density determinations by using varying radiator thicknesses at constant etching time and by using varying etching times at fixed radiator thickness, respectively. For both methods studied a computer programme is made to calculate the theoretically expected neutron sensitivity as a function of neutron energy. For both methods the neutron sensitivities, expressed in terms of observable etched proton tracks per neutron, are determined experimentally for 3.3 and 14.7 MeV neutron energies. The theoretical and experimental data obtained are compared.

  7. Fast neutron spectrometry based on proton detection in CR-39 detector

    International Nuclear Information System (INIS)

    Dajko, G.; Somogyi, G.

    1986-01-01

    The authors have developed a home-made proton-sensitive CR-39 track detector called MA-ND/p. Using this and the n-p scattering process the performance of a fast neutron spectrometer has been studied by applying two different methods. These are based on track density determinations by using varying radiator thicknesses at constant etching time and by using varying etching times at fixed radiator thickness, respectively. For both methods studied a computer programme is made to calculate the theoretically expected neutron sensitivity as a function of neutron energy. For both methods the neutron sensitivities, expressed in terms of observable etched proton tracks per neutron, are determined experimentally for 3.3 and 14.7 MeV neutron energies. The theoretical and experimental data obtained are compared. (author)

  8. Use of Image Pro Plus for counting of {alpha} particles tracks in CR-39; Uso do Image Pro Plus para contagem de tracos de particulas {alpha} em CR-39

    Energy Technology Data Exchange (ETDEWEB)

    Miranda, Marcia Valeria F.E. Sa [Coordenacao dos Programas de Pos-Graduacao de Engenharia (COPPE/UFRJ), Rio de Janeiro, RJ (Brazil). Programa de Engenharia Nuclear; Centro Regional de Ciencias Nucleares (CRCN-NE/CNEN-PE), Recife, PE (Brazil); Crispim, Verginia Reis [Coordenacao dos Programas de Pos-Graduacao de Engenharia (COPPE/UFRJ), Rio de Janeiro, RJ (Brazil). Programa de Engenharia Nuclear; Gomes, Rogerio dos S.; Gomes, Joana D' Arc R. Lopes, E-mail: mvaleria@cnen.gov.b, E-mail: verginia@con.ufrj.b, E-mail: rogeriog@cnen.gov.b, E-mail: jlopes@cnen.gov.b [Comissao Nacional de Energia Nuclear (CNEN), Rio de Janeiro, RJ (Brazil)

    2011-10-26

    This paper measured the radon radiations present in NORM samples, through the diffusion chambers which contained a nuclear track detector (CR-39). For automatic counting of those tracks the computer program Image Pro plus was used. This paper reports the application of Image Pro plus for counting the nuclear tracks, coming from the radon radiation present in NORM samples. As the radiation rate of {sup 222}Rn if proportional to the number of these tracks, the methodology allowed to compare the levels of contamination of the analysed samples. Also, tables and graphics are presented with counting results referring to the stage of validation of Image Pro plus

  9. A study of CR-39 track response to charged particles from NOVA implosions

    International Nuclear Information System (INIS)

    Phillips, T.W.; Cable, M.D.; Hicks, D.G.; Li, C.K.; Petrasso, R.D.; Seguin, F.H.

    1996-01-01

    We have exposed CR-39 track recording material to a number of NOVA implosions. Radiation from the implosion passed through an array of ranging filters, which aided identification of the incident particles and their energies. The etching procedure was calibrated by including a piece of track exposed to DD protons from a small accelerator. For the same shots, we quantitatively compare the DD neutron yield with the DD proton yield determined from the track. In DT implosions, tracks produced by neutron interactions prevent observation of charged-particle tracks that are produced by the processes of knock-on, secondary or tertiary fusion

  10. Autoradiographic measurement of low concentrations of alpha-active nuclides using CR-39 track detectors

    International Nuclear Information System (INIS)

    Freyer, K.; Dietze, K.; Weisse, S.; Kummer, G.

    1991-01-01

    An autoradiographic method for the determination of alpha emission rates from plastic packaging materials for VLSI silicon memory devices based on long-time exposure of the samples on CR-39 detectors has been tested. The lower limit of detection will be strongly influenced by the background of the detector material and amounts at times to 0.002 alpha particles cm -2 h -1 after 200 days exposure. A mathematical method for the interpretation of very low track densities is discussed. The first results of its application are presented. (author)

  11. Detection of fission fragments and alpha particles using the solid trace detector CR-39

    International Nuclear Information System (INIS)

    Santos, R.C.

    1988-01-01

    The technique of detecting charged particles using the solid track detector CR-39 is employed to establish some characteristics of fission fragments and alpha particles emitted from a Cf-252 source. Results are presented and discussed on the following aspects i) distribution of the track diameters; ii) variations on the track diameters to the chemical attack; iii) variations of the chemical attack velocity with respect to concentration and temperature. iv) activation energy of the developping process; v) induction time; vi) critical angle and efficiency on track developping. (A.C.A.S.) [pt

  12. Response of LR-115 type II and CR-39 plastic track detectors to Am-Be and 14.1-MeV neutrons

    International Nuclear Information System (INIS)

    Bradley, D.A.; Chong, C.S.; Saat, Ahmat; Sidik, A.G.; Ghose, A.M.

    1987-01-01

    The fast-neutron response of the plastic LR-115 type II and CR-39 track detectors have been compared, using a 14.1-MeV neutron generator and a radionuclide Am-Be neutron source (effective primary neutron energy 4.5-MeV). The distribution of track diameters for a range of etching times has been evaluated, taking into account track registration efficiency and the relevant fast neutron scattering cross-sections. The efficiency of etched-track formation in LR-115 type II due to neutron irradiation is approximately double that in CR-39. The 14.1-MeV neutrons also tend to produce tracks in both materials with somewhat greater efficiency than do the lower energy neutrons from the radionuclide source, for a given etching time. (author)

  13. Estudos de avaliação econômica de tecnologias em saúde: roteiro para análise crítica

    Directory of Open Access Journals (Sweden)

    Everton Nunes da Silva

    2014-03-01

    Full Text Available OBJETIVO: Propor uma ferramenta para análise crítica de estudos de avaliação econômica a partir da síntese de roteiros existentes na literatura. MÉTODOS: Foram realizadas buscas em: MEDLINE, Embase, Centre for Reviews and Dissemination e International Society for Pharmacoeconomics and Outcomes Research. Dois pesquisadores selecionaram independentemente os estudos e extraíram os dados de interesse. Quantificou-se o número de perguntas que os roteiros continham sobre os seguintes domínios: delineamento do estudo; mensuração dos custos e dos desfechos em saúde; análise e interpretação dos resultados; e informações gerais. Após elaboração da matriz contendo os itens de cada domínio por estudo, os autores construíram um instrumento para análise crítica. RESULTADOS: Foram localizados 406 artigos não duplicados, dos quais 19 foram incluídos. No total, foram identificadas 566 perguntas nos roteiros desses estudos. Dessas, 109 (19% tratavam de desfechos em saúde, 93 (16% de quantificação dos custos, 73 (13% de modelagem, 54 (10% de generalização dos resultados e 52 (9% de incertezas. O roteiro de análise crítica resultante contém 32 perguntas organizadas em quatro domínios: delineamento do estudo, mensuração dos custos e dos desfechos em saúde, análise e interpretação dos resultados e informações gerais. CONCLUSÕES: O instrumento de análise crítica proposto pode auxiliar na uniformização do julgamento da qualidade da evidência de todos os tipos de avaliação econômica.

  14. The influence of chemical etching time on efficiency of radon detection using CR-39

    Energy Technology Data Exchange (ETDEWEB)

    Reway, Adriana P.; Kappke, Jaqueline; Narloch, Danielle C., E-mail: adrireway@hotmail.com, E-mail: jaquelinekappke@gmail.com, E-mail: daninarloch@hotmail.com [Universidade Tecnologica Federal do Parana (UTFPR), Curitiba, PR (Brazil). Departamento Academico de Fisica; Del Claro, Flavia; Paschuk, Sergei A., E-mail: flaviadelclaro@gmail.com, E-mail: spaschuk@gmail.com [Universidade Tecnologica Federal do Parana (UTFPR), Curitiba, PR (Brazil). Programa de Pos-Graduaca em Engenharia Eletrica e Informatica Industrial; Correa, Janine N., E-mail: janine_nicolosi@hotmail.com [Universidade Tecnologica Federal do Parana (UTFPR), Curitiba, PR (Brazil). Departamento Academico de Construcao Civil

    2015-07-01

    Natural radiation is the principal source of human exposure to ionizing radiation. Radon is noble radioactive gas that emanates from the soil and rocks entering the atmosphere of dwellings where it could be accumulated. The inhalation of {sup 222}Rn represents a significant health risk. Solid-State Nuclear Track Detectors (SSNTD) represents an efficient method for alpha particle detection and measurements of the activity concentration of {sup 222}Rn. The aim of present work was to study the etching time impact on CR-39 efficiency in radon activity measurements. The investigation was performed using 80 CR-39 detectors, which were exposed to a source of radon. After the exposition, alpha particle tracks development was achieved by chemical etching using 6.25M NaOH solution and ethanol (2%) at 70°C. Etching alpha particle tracks were identified and counted manually using the optical microscope with magnification of 100x and glass overlay mask. The etching time ranged from 7 to 14 hours. The results show that there is an increase in the number of visible tracks with increased etching time. The number of traces obtained for 7 hours and 8 hours of revelation was 1430 +/- 90 and 2090 +/- 160, respectively. However, for etching time of 13 and 14 hours was not observed statistical increase in the number of visible tracks. The number of tracks in this situation was 3630 +/- 180 and 3870 +/- 160 to 13 and 14 hours etching. Thus, for assumed etching parameters, the etching optimal time was observed 14 hours. (author)

  15. The influence of chemical etching time on efficiency of radon detection using CR-39

    International Nuclear Information System (INIS)

    Reway, Adriana P.; Kappke, Jaqueline; Narloch, Danielle C.; Del Claro, Flavia; Paschuk, Sergei A.; Correa, Janine N.

    2015-01-01

    Natural radiation is the principal source of human exposure to ionizing radiation. Radon is noble radioactive gas that emanates from the soil and rocks entering the atmosphere of dwellings where it could be accumulated. The inhalation of 222 Rn represents a significant health risk. Solid-State Nuclear Track Detectors (SSNTD) represents an efficient method for alpha particle detection and measurements of the activity concentration of 222 Rn. The aim of present work was to study the etching time impact on CR-39 efficiency in radon activity measurements. The investigation was performed using 80 CR-39 detectors, which were exposed to a source of radon. After the exposition, alpha particle tracks development was achieved by chemical etching using 6.25M NaOH solution and ethanol (2%) at 70°C. Etching alpha particle tracks were identified and counted manually using the optical microscope with magnification of 100x and glass overlay mask. The etching time ranged from 7 to 14 hours. The results show that there is an increase in the number of visible tracks with increased etching time. The number of traces obtained for 7 hours and 8 hours of revelation was 1430 +/- 90 and 2090 +/- 160, respectively. However, for etching time of 13 and 14 hours was not observed statistical increase in the number of visible tracks. The number of tracks in this situation was 3630 +/- 180 and 3870 +/- 160 to 13 and 14 hours etching. Thus, for assumed etching parameters, the etching optimal time was observed 14 hours. (author)

  16. A study of CR-39 plastic charged-particle detector replacement by consumer imaging sensors

    Energy Technology Data Exchange (ETDEWEB)

    Plaud-Ramos, K. O.; Freeman, M. S.; Wei, W.; Guardincerri, E.; Bacon, J. D.; Cowan, J.; Durham, J. M.; Huang, D.; Gao, J.; Hoffbauer, M. A.; Morley, D. J.; Morris, C. L.; Poulson, D. C.; Wang, Zhehui, E-mail: zwang@lanl.gov [Los Alamos National Laboratory, Los Alamos, New Mexico 87545 (United States)

    2016-11-15

    Consumer imaging sensors (CIS) are examined for real-time charged-particle detection and CR-39 plastic detector replacement. Removing cover glass from CIS is hard if not impossible, in particular for the latest inexpensive webcam models. We show that $10-class CIS are sensitive to MeV and higher energy protons and α-particles by using a {sup 90}Sr β-source with its cover glass in place. Indirect, real-time, high-resolution detection is also feasible when combining CIS with a ZnS:Ag phosphor screen and optics. Noise reduction in CIS is nevertheless important for the indirect approach.

  17. Measurement of fast neutron spectrum using CR-39 detectors and a new image analysis program (autoTRAKn)

    International Nuclear Information System (INIS)

    Paul, Sabyasachi; Tripathy, S.P.; Sahoo, G.S.; Bandyopadhyay, T.; Sarkar, P.K.

    2013-01-01

    An attempt is made to estimate the neutron spectrum using the CR-39 (Solid state nuclear track) detector and a new image analyzing program. For this purpose the earlier developed program (autoTRAK) is modified by introducing the required features such as angular correction for the recoil particles, fluence-to-dose conversion coefficient, detection sensitivity of CR-39 detectors, etc. to make it applicable for neutron spectrometry and dosimetry. This upgraded program (autoTRAK n ) is tested with a mono-energetic source (D–T) and two other standard neutron sources, viz. 241 Am–Be and 252 Cf. The program is validated by reproducing these standard spectra, and comparing with the spectra reported by other investigators using different measuring techniques. The ratios of dose equivalent (H ⁎ (10)) to fluence (Φ) are also estimated from the spectra and are compared with the reference values for these neutron sources. An additional feature of this program is explored for counting high density overlapping tracks more precisely and effectively compared to other commonly used image analyzing softwares. This method is found to be simple and promising, which can always be used as a supplementary measuring technique. The details of the modified program, reproduction and comparison of the neutron spectra, reproducibility of the methodology and example of overlapping track counting are presented and discussed. -- Highlights: •A novel image analysis technique (autoTRAK n ) is developed to evaluate CR-39 detectors used for neutron spectrometry and dosimetry. •The methodology is tested to reproduce three standard neutron spectra, (a) D–T, (b) 241 Am–Be, and (c) 252 Cf. •A good matching is observed between dosimetric values obtained by the program and the available reference values. •The program autoTRAK n is also observed to be efficient to distinguish high density overlapping tracks without any segregation procedure. •The methodology seems to be simple, which

  18. Measurement of the variable track-etch rate of hydrogen, carbon and oxygen Ions in CR-39

    International Nuclear Information System (INIS)

    Lengar, I.; Skvarc, J.; Ilic, R.

    2003-01-01

    The ratio of the track-etch rate to the bulk-etch rate for hydrogen, carbon and oxygen ions was studied for the CR-39 detector with addition of dioctylphthalate. The response was reconstructed from etch-pit growth curves obtained by the multi-step etching technique. A theoretical analysis of the correctness of the method due to the 'missing track segment' is assessed and utilisation of the results obtained for the calibration of fast neutron dosimetry is discussed. (author)

  19. A performance test of a new high-surface-quality and high-sensitivity CR-39 plastic nuclear track detector – TechnoTrak

    Energy Technology Data Exchange (ETDEWEB)

    Kodaira, S., E-mail: kodaira.satoshi@qst.go.jp [Radiation Measurement Research Team, National Institute of Radiological Sciences, National Institutes for Quantum and Radiological Science and Technology, Chiba (Japan); Morishige, K. [Research Institute for Science and Engineering, Waseda University, Tokyo (Japan); Kawashima, H.; Kitamura, H.; Kurano, M. [Radiation Measurement Research Team, National Institute of Radiological Sciences, National Institutes for Quantum and Radiological Science and Technology, Chiba (Japan); Hasebe, N. [Research Institute for Science and Engineering, Waseda University, Tokyo (Japan); Koguchi, Y.; Shinozaki, W. [Oarai Research Center, Chiyoda Technol Corporation, Ibaraki (Japan); Ogura, K. [College of Industrial Technology, Nihon University, Chiba (Japan)

    2016-09-15

    We have studied the performance of a newly-commercialized CR-39 plastic nuclear track detector (PNTD), “TechnoTrak”, in energetic heavy ion measurements. The advantages of TechnoTrak are derived from its use of a purified CR-39 monomer to improve surface quality combined with an antioxidant to improve sensitivity to low-linear-energy-transfer (LET) particles. We irradiated these detectors with various heavy ions (from protons to krypton) with various energies (30–500 MeV/u) at the heavy ion accelerator facilities in the National Institute of Radiological Sciences (NIRS). The surface roughness after chemical etching was improved to be 59% of that of the conventional high-sensitivity CR-39 detector (HARZLAS/TD-1). The detectable dynamic range of LET was found to be 3.5–600 keV/μm. The LET and charge resolutions for three ions tested ranged from 5.1% to 1.5% and 0.14 to 0.22 c.u. (charge unit), respectively, in the LET range of 17–230 keV/μm, which represents an improvement over conventional products (HARZLAS/TD-1 and BARYOTRAK). A correction factor for the angular dependence was determined for correcting the LET spectrum in an isotropic radiation field. We have demonstrated the potential of TechnoTrak, with its two key features of high surface quality and high sensitivity to low-LET particles, to improve automatic analysis protocols in radiation dosimetry and various other radiological applications.

  20. Etching characteristics of a CR-39 track detector at room temperature in different etching solutions

    International Nuclear Information System (INIS)

    Dajko, G.

    1991-01-01

    Investigations were carried out to discover how the etching characteristics of CR-39 detectors change with varying conditions of the etching process. Measurements were made at room temperature in pure NaOH and KOH solutions; in different alcoholic KOH solutions (PEW solution, i.e. potassium hydroxide, ethyl alcohol, water); and in NaOH and KOH solutions containing different additives. The bulk etching rate of the detector (V B ) and the V (= V T /V B ) function, i.e. track to bulk etch rates ratio, for 6.1 MeV α-particles, were measured systematically. (author)

  1. Experimental and Monte Carlo simulation studies of open cylindrical radon monitoring device using CR-39 detector

    Energy Technology Data Exchange (ETDEWEB)

    Rehman, Fazal-ur- E-mail: fazalr@kfupm.edu.sa; Jamil, K.; Zakaullah, M.; Abu-Jarad, F.; Mujahid, S.A

    2003-07-01

    There are several methods of measuring radon concentrations but nuclear track detector cylindrical dosimeters are widely employed. In this investigation, the consequence of effective volumes of the dosimeters on the registration of alpha tracks in a CR-39 detector was studied. In a series of experiments an optimum radius for a CR-39-based open cylindrical radon dosimeter was found to be about 3 cm. Monte Carlo simulation techniques hav been employed to verify the experimental results. In this context, a computer code Monte Carlo simulation dosimetry (MOCSID) was developed. Monte Carlo simulation experiments gave the optimum radius of the dosimeters as 3.0 cm. The experimental results are in good agreement with those obtained by Monte Carlo design calculations. In addition to this, plate-out effects of radon progeny were also studied. It was observed that the contribution of radon progeny ({sup 218}Po and {sup 214}Po) plated-out on the wall of the dosimeters increases with an increase of dosimeter radii and then decrease to 0 at a radius of about 3 cm if a point detector has been installed at the center of the dosimeter base. In the code MOCSID different types of random number generators were employed. The results of this research are very useful for designing an optimum size of radon dosimeters.

  2. Experimental and Monte Carlo simulation studies of open cylindrical radon monitoring device using CR-39 detector

    International Nuclear Information System (INIS)

    Rehman, Fazal-ur-; Jamil, K.; Zakaullah, M.; Abu-Jarad, F.; Mujahid, S.A.

    2003-01-01

    There are several methods of measuring radon concentrations but nuclear track detector cylindrical dosimeters are widely employed. In this investigation, the consequence of effective volumes of the dosimeters on the registration of alpha tracks in a CR-39 detector was studied. In a series of experiments an optimum radius for a CR-39-based open cylindrical radon dosimeter was found to be about 3 cm. Monte Carlo simulation techniques hav been employed to verify the experimental results. In this context, a computer code Monte Carlo simulation dosimetry (MOCSID) was developed. Monte Carlo simulation experiments gave the optimum radius of the dosimeters as 3.0 cm. The experimental results are in good agreement with those obtained by Monte Carlo design calculations. In addition to this, plate-out effects of radon progeny were also studied. It was observed that the contribution of radon progeny ( 218 Po and 214 Po) plated-out on the wall of the dosimeters increases with an increase of dosimeter radii and then decrease to 0 at a radius of about 3 cm if a point detector has been installed at the center of the dosimeter base. In the code MOCSID different types of random number generators were employed. The results of this research are very useful for designing an optimum size of radon dosimeters

  3. Ion beam techniques for analyzing polymers irradiated by ions

    International Nuclear Information System (INIS)

    Rickards, J.; Zironi, E.P.; Andrade, E.; Dominguez, B.

    1992-01-01

    In the study of the effects of ion beam irradiation of polymers very large doses can be administered in short times. Thousands of MGy can be produced in a small volume of a sample in a few minutes by bombarding with typical ion beam currents. For instance, in an experiment done to observe the effects of 750 keV proton irradiation PVC, using a collimator of 1 mm diameter, 1 μC of charge integration deposits a dose of 50 MGy. The use of ion beams also opens up the possibility of using the same beam for irradiation and for analysis of the effects, using the well known ion beam analysis techniques. PIXE allows the measurement of chlorine in PVC. Polymers containing fluorine can be measured with the resonant nuclear reaction (RNR) technique, which is specific only to certain elements. The amount of hydrogen in the sample and its profile can be obtained using energy recoil detection analysis (ERDA); carbon, oxygen, and nitrogen can be measured and profiled using Rutherford backscattering (RBS) and also using the (d,p) and (d, α) nuclear reactions (NR). Loss of mass is one effect that can be studied using these techniques. It was studied in two different polymers, PVC and CR-39, in order to determine carbon buildup during ion irradiation. It was concluded that carbon builds up following different mechanisms in these two materials, due to the different possibilities of forming volatile compounds. It is also suggested that CR-39 should be a good material for ion beam lithography. (author)

  4. Tetraethyl ammonium hydroxide (TEAH) as etchant of CR-39 for the determination of fluence of alpha particles

    Energy Technology Data Exchange (ETDEWEB)

    Joshirao, Pranav M.; Vyas, Chirag K.; Eappen, K.P. [Department of Energy Science, Sungkyunkwan University, Suwon 440746 (Korea, Republic of); Shin, Jae Won [Department of Physics, Sungkyunkwan University, Suwon 440746 (Korea, Republic of); Hong, Seung-Woo [Department of Energy Science, Sungkyunkwan University, Suwon 440746 (Korea, Republic of); Department of Physics, Sungkyunkwan University, Suwon 440746 (Korea, Republic of); Manchanda, Vijay K., E-mail: vkm49@skku.edu [Department of Energy Science, Sungkyunkwan University, Suwon 440746 (Korea, Republic of); School of Electronics and Electrical Engineering, Sungkyunkwan University, Suwon 440746 (Korea, Republic of)

    2014-04-01

    Highlights: • Etching time of CR-39 with TEAH–NaOH mixture (at 80 °C) is less than 20 min. • Etched products enhance etching rate. • V{sub B} and V{sub T} values increase exponentially with temperature. • Activation energy of bulk etching and track etching were determined as 0.87 ± 0.02 eV. - Abstract: Choice of chemical etchant and temperature are pivotal to the successful employment of organic/polymeric solid state nuclear track detectors for determining the fluence of charged particles like protons, alpha and other heavy ions. Poly(diethyleneglycol-bis-(allylcarbonate)) (CR-39) is one of the most sensitive detectors for monitoring the alpha particles but suffers from the drawback of long etching period. An attempt has been made in the present work to investigate a mixture, 20% (v/v) tetraethylammonium hydroxide (40%) – 80% NaOH (6 M) (TEAH–NaOH) at varying temperature as an alternate etchant. It was found that bulk/track etch rate increased and as a consequence etching time decreased significantly (about 10 times) when the mixture was used at 80 °C. Mechanistically, improved efficiency of TEAH–NaOH was attributed to its larger organophilicity and lower etching activation energy as compared to NaOH.

  5. Design and development of wide energy neutron REM equivalent spectrometer-dosimeters based on polycarbonates and Cr-39

    International Nuclear Information System (INIS)

    Faermann, S.

    1985-03-01

    This work describes a system composed of a Rem response personnel neutron dosemeter, based on boron radiators and a polycarbonate track detector, for monitoring dose equivalents in the energy range 1 eV to 14 MeV, an electrochemical etching system for revealing damage sites in solid state track etch detectors, a reader for magnifying the etched pits and a microprocessor for evaluating the dose equivalents and their uncertainties. The performance and directional dependence of the dosemeter when exposed to monoenergetic and polyenergetic neutron fields in the epithermal and fast energy regions are discussed. Saturation effects in polycarbonate foils are presented and a comparison is made between the response of polycarbonate and CR-39 foils, used as passive detectors in the dosemeter. A new passive miniature fast neutron spectrometer-dosimeter is also described. The device is based on the detection of proton tracks by electrochemical etching of CR-39 foils covered with thin polyethylene layers of different thicknesses. By means of this device it is possible to assess the fast neutron energy spectrum in 10 energy intervals in the energy range 0.5-15 MeV. Dose equivalents can be determined in the dose equivalent range 20 mRem to 8 Rem, approximately (author)

  6. Use of Image Pro Plus for counting of α particles tracks in CR-39

    International Nuclear Information System (INIS)

    Miranda, Marcia Valeria F.E. Sa; Crispim, Verginia Reis

    2011-01-01

    This paper measured the radon radiations present in NORM samples, through the diffusion chambers which contained a nuclear track detector (CR-39). For automatic counting of those tracks the computer program Image Pro plus was used. This paper reports the application of Image Pro plus for counting the nuclear tracks, coming from the radon radiation present in NORM samples. As the radiation rate of 222 Rn if proportional to the number of these tracks, the methodology allowed to compare the levels of contamination of the analysed samples. Also, tables and graphics are presented with counting results referring to the stage of validation of Image Pro plus

  7. Interaction of 80 MeV PI+ with different targets: Track detector studies

    Energy Technology Data Exchange (ETDEWEB)

    Tabassum, L; Chohan, A S [Government Coll., Lahore. (Pakistan) Deptt. of Physics Khan, H.A. (Pakistan Inst. of Nuclear Science and Technology, Islamabad (Pakistan). Nuclear Engineering Div.)

    1990-04-01

    CR-39 and mica track detectors have been used in the study of the interactions of 80 MeV PI+ with thin targets of Bi, Pb, Ho, Sb. The binary fission cross sections, the length and angular distributions of etched tracks have been obtained. The cross-section values obtained by using CR-39 are higher as compared to those obtained with mica. (author).

  8. Interaction of 80 MeV PI+ with different targets: Track detector studies

    International Nuclear Information System (INIS)

    Tabassum, L.; Chohan, A.S.

    1990-01-01

    CR-39 and mica track detectors have been used in the study of the interactions of 80 MeV PI+ with thin targets of Bi, Pb, Ho, Sb. The binary fission cross sections, the length and angular distributions of etched tracks have been obtained. The cross-section values obtained by using CR-39 are higher as compared to those obtained with mica. (author)

  9. Practical consequences for the use of a personal dosimeter for fast neutrons based on CR39 exposed up to one year

    International Nuclear Information System (INIS)

    Boschung, Markus; Fiechtner, Annette; Mayer, Sabine; Wernli, Christian

    2008-01-01

    Full text: At the Paul Scherrer Institut a personal neutron dosimetry system based on chemically etched CR-39 detectors and automatic track counting is in routine use since 1998. In its original design, the dosimeter is sensitive to thermal neutrons and to neutrons in the energy range from 200 keV up to several MeV. The standard exposition period is 3 months. Recently, a novel concept for individual monitoring was implemented at CERN. In this concept, each worker who possibly enters a radiation zone is equipped with a combined dosimeter for the measurement of personal photon and neutron doses. The dosimeter for photon dose measurement has an instant readout capability and dose measurements are done monthly. The dosimeter for neutron measurement is based on CR-39 detectors and is sensitive to fast neutrons only. The CR-39 detector is only evaluated and a neutron dose determined if the monthly personal photon dose exceeds 2 mSv or if the exposition period of the neutron dosimeter exceeds one year. This novel regime of use of the neutron dosimeter has had some important consequences for its practical implementation. A priori, the wearing period of a neutron dosimeter is not known and can range from 1 month up to 12 or even more months. A good knowledge of the long-term behaviour and characteristics of the detector material is needed. But also organisational and administrative issues have to be considered. The paper will outline the adopted procedure covering not only technical but also organisational aspects. The long-term behaviour of background track density and response to 241 Am-Be over one year are described as well as calibrations performed with 241 Am-Be and 252 Cf sources and in the High-Energy Reference Field Facility at CERN (CERF). The concept of individual monitoring at CERN could be transferred to other locations with high energy accelerators such as PSI and DESY. The experience gained with the neutron dosimeter based on CR-39 since introduction of the

  10. Change in the sensitivity of CR-39 for alpha-tracks after the storage at different temperatures

    International Nuclear Information System (INIS)

    Enomoto, Hiroko; Ishigure, Nobuhito

    2000-01-01

    The effect of storage on track registration property of CR-39 has been investigated. Pieces of CR-39 plate were irradiated with normally incident α-particles and fission fragments using a 252 Cf source prior and posterior to the storage of them in air for one year at different temperatures of -80degC, -23degC, 4degC, 23degC and 35degC. Periodical etching was performed for the pieces stored at different temperatures using the solution of NaOH with 7 mol+l -1 at 70degC for 4 hours. Bulk etch rate (V b ) was obtained from the etch pit diameter (D f ) of fission tracks using the equation: V b =D f /(2t), where t is etching time (h). The sensitivity for α-tracks (S) was obtained from the ratio of the etch pit diameters between α-tracks (D a ) and fission-tracks using the equation: S={1+(D a /D f ) 2 }/{1-(D a /D f ) 2 }-1. The present results show that both the bulk etch rate and α-track sensitivity are not constant, which tend to decrease with storage times and storage temperatures. At -80degC, -23degC and 4degC the change in the sensitivity was negligible. On the other hand, the storage at 23degC for 1 year decreased the sensitivity down to 74%. The most significant effect was observed on the α-track sensitivity at 35degC, which was reduced to 80% for one month, 61% for three months, 42% for six months and 32% for one year. By the comparison of experiments between fading and ageing it is shown that such storage effect is attributed not to fading of latent tracks but mainly to some changes in the detector itself. When CR-39 is used of radon monitoring or neutron monitoring, the following points should be paid attention to: (1) the detector should be stored in a refrigerator before exposure and until etching after the exposure, (2) the change in the sensitivity between the time of calibration and the time of use should be evaluated and the counting efficiency at the measurement should be corrected and (3) for comparison or for interpretation of experimental results

  11. Theoretical calculation on CR-39 response for radon measurements and optimum diffusion chambers dimensions

    Energy Technology Data Exchange (ETDEWEB)

    Askari, H.R.; Ghandi, Kh. [Department of Physics, Faculty of Science, Vali-e-Asr University, Rafsanjan 7713936417 (Iran, Islamic Republic of); Rahimi, M. [Department of Physics, Faculty of Science, Vali-e-Asr University, Rafsanjan 7713936417 (Iran, Islamic Republic of)], E-mail: rahimi_bam@yahoo.com; Negarestani, A. [International Center for Science and High Technology and Environmental Sciences, Kerman (Iran, Islamic Republic of)

    2008-11-11

    One method to measure radon gas concentration in the air with a long time of radiation is trace chemical etching technique. There is a direct proportion between the number of traces on solid-state nuclear track detectors (SSNTDs) and activity concentration of radon. In this paper, calibration constant for a cylindrical chamber with CR-39 detector has been measured analytically. Using this measurement, trace curves on the base of concentration for chambers with different heights and radii have been drawn. The results show that to measure radon gas concentration, the optimum chamber should have a height between 3.5 and 4 cm and a radius between 2.5 and 3.2 cm.

  12. Theoretical calculation on CR-39 response for radon measurements and optimum diffusion chambers dimensions

    International Nuclear Information System (INIS)

    Askari, H.R.; Ghandi, Kh.; Rahimi, M.; Negarestani, A.

    2008-01-01

    One method to measure radon gas concentration in the air with a long time of radiation is trace chemical etching technique. There is a direct proportion between the number of traces on solid-state nuclear track detectors (SSNTDs) and activity concentration of radon. In this paper, calibration constant for a cylindrical chamber with CR-39 detector has been measured analytically. Using this measurement, trace curves on the base of concentration for chambers with different heights and radii have been drawn. The results show that to measure radon gas concentration, the optimum chamber should have a height between 3.5 and 4 cm and a radius between 2.5 and 3.2 cm.

  13. Evidence of formation of trans-Fe nuclei in Fe+Al interactions at 1.88 GeV using Cr-39 (DOP) detector

    International Nuclear Information System (INIS)

    Ganguly, A.K.; Chaudhuri, Biva

    1991-01-01

    A wedge-shaped aluminium target was irradiated with 1.88 A GeV Fe beam to study various features of Fe+Al nucleus-nucleus interaction and their dependence on target thickness. The detector employed was a stack of CR-39 (DOP) and Lexan plastic nuclear track detectors which have a characteristically high charge resolution property. To distinguish the actual events from background and buildup a selection criteria for easy and unambiguous rejection of unwanted interfering events the stack of detectors was placed at an angle of 60deg with respect to the beam. After irradiation the CR-39 (DOP) detectors were etched and the elliptic etch-pit diameters were scanned. The diameter distribution of the elliptic etch-pits exhibits the existence of trans Fe nuclei. The production of trans Fe fraction is seen to increase with the thickness of the aluminium target. The possible causes of this increase are being investigated. (author). 12 refs., 4 figs

  14. Anillo mitral asimétrico en la corrección de la insuficiencia mitral isquémica crónica: resultados clínicos y predictores ecocardiográficos de recidiva

    Directory of Open Access Journals (Sweden)

    Carmen Iglesias-Gil

    2017-07-01

    Conclusiones: La anuloplastia con anillo IMR ETlogix® es una técnica segura y eficaz para corregir la IM isquémica crónica, fundamentalmente en pacientes con una altura de tenting preoperatoria inferior a 10,65 mm.

  15. Preliminary results of fission induced by (1068 MeV) pi in Cu, Sn, Au and Bi using CR-39 detectors

    CERN Document Server

    Khan, H A; Shahzad, M I; Manzoor, S; Farooq, M A; Sher, G; Khan, E U; Peterson, R J

    1999-01-01

    Fission probabilities in pion induced reactions exhibit characteristic variations with respect to pion energies and target fissility values. At incident energies well above the pion-nucleon resonances, the statistical model seems to give good description of the observed data. We have used negative pions of energy 1068 MeV, in order to study fission induced in four target materials with fissility values [(Z-1)2/A] ranging from 12 to 32. All targets were arranged in a single stack in such a way that each target coated on a CR-39 detector was sandwiched by another uncoated CR-39 detector plate. The stack was irradiated at the AGS of Brookhaven National Laboratory (USA). This set-up ensures solid angle coverage of almost 4 pi degrees, so that for each fission event one of the fission fragments is expected to be trapped by the forward detector and one by the detector covering backward hemisphere. The effect of pion momentum transfer to the struck nucleus was observed in the form of asymmetry between events counted...

  16. Characterization of plastic nuclear track detectors on solid state, CR-39 and LR-115 and its possibilities application on thermal and fast neutron dosimetry

    International Nuclear Information System (INIS)

    Vallejo Delgado, L.R.

    1989-01-01

    This work is an study about the use feasibility of plastic nuclear track detectors, LR 115, II-B (of Eastmann Kodak Co) and CR-39 (of American Acrylics and Plastics), for thermal and fast neutron dosimetry, respectively. The LR-115 with converter (n, alpha) was exposed to thermal neutrons with energy of 0,046 e V, proceeding from nuclear reactor RECH-1 of Nuclear Energy Chilean Commission. The irradiated films were submited to a chemical etching with NaOH, plus a washing and brushing. The CR-39 with polyethylene irradiator, was exposed to fast neutrons proceeding of calibrated sources of Am-Se. The irradiated plates were submited to a chemical pre-etching with KOH and a electrochemical post-etching. (author)

  17. Activation energy of etching for CR-39 as a function of linear energy transfer of the incident particles

    CERN Document Server

    Awad, E M

    1999-01-01

    In this work, we have studied the effect of the radiation damage caused by the incident particles on the activation energy of etching for CR-39 samples. The damage produced by the incident particle is expressed in terms of the linear energy transfer (LET). CR-39 samples from American Acrylic were irradiated to three different LET particles. These are N (LET sub 2 sub 0 sub 0 = 20 KeV/mu m) as a light particle, Fe (LET sub 2 sub 0 sub 0 = 110 KeV/mu m) as a medium particle and fission fragments (ff) from a sup 2 sup 5 sup 2 Cf source as heavy particles. In general the bulk etch rate was calculated using the weight difference method and the track etch rate was determined using the track geometry at various temperatures (50-90 deg. C) and concentrations (4-9 N) of the NaOH etchant. The average activation energy E sub b related to the bulk etch rate v sub b was calculated from 1n v sub b vs. 1/T. The average activation energy E sub t related to the track etch rate v sub t was estimated from 1n v sub t vs. 1/T. It...

  18. Triton, deuteron and proton responses of the CR-39 track detector

    Energy Technology Data Exchange (ETDEWEB)

    Yamauchi, Tomoya; Matsumoto, Hiroyoshi; Oda, Keiji [Kobe Univ. of Mercantile Marine (Japan)

    1996-07-01

    In the present study, we assessed the response of the CR-39 detector to proton, deuteron and triton from their etch-pit growth curves obtained by multi-step etching technique and the difference among their track registration properties was discussed. In order to avoid incorrect evaluation due to the missing track effect, particle irradiation was performed at various incident energies. The response function, S(R), etch rate ratio, S, as a function of the residual range, R, was experimentally evaluated for all hydrogen isotopes by this method. In the next, we obtained another form of response functions of S(E), S({beta}) and S(LET{sub 200}), which were presented as functions of the particle energy, E, the particle velocity, {beta}(=v/c), and the linear energy transfer in the case where the cut-off energy is 200 eV, LET{sub 200}, respectively. These information will be useful also in understanding the fundamentals of the latent track formation mechanism in the plastic track detectors. (J.P.N.)

  19. Interaction of 84 MeV/u 12C with 208Pb target investigated with CR-39 plastic track detector

    International Nuclear Information System (INIS)

    Grabez, B.

    1984-01-01

    The interaction of the 84 MeV/u 12 C ions with 208 Pb target was investigated using CR-39 plastic track detector. The first part of the work was dedicated to the examination of the methodology of the recently presented CR-39 detector and its calibration. Measurements have been done on tracks of various ions in the broad atomic number region from Z = 2 to Z = 92. The possibility of the identification of low energy fragments produced in nuclear interactions by measurements on the finished tracks was studied. Our results show that very good charge resolution can be achieved through determination of the mean etch rate ratio and the range of low energy ions. In the second part of the work it was shown that the main reaction channels in the interaction of 84 MeV/u C with Pb target are spallation, fission and fragmentation. The contribution of the multifragmentation is less than 1% of the total reaction cross section. From our results follows that the most probable reaction channels after collision with small impact parameter are fragmentation and deep spallation. The spallation and fission come after more peripheral collisions. (orig./HSI)

  20. Measurement of concentrations of radon and its daughters in indoor atmosphere using CR-39 nuclear track detector

    International Nuclear Information System (INIS)

    Khan, A.J.; Sharma, K.C.; Varshney, A.K.; Prasad, Rajendra; Tyagi, R.K.

    1988-01-01

    The concentrations of radon and its daughters in rooms having different environmental conditions are measured using CR-39 nuclear track detector. It has been found that the radon concentration inside the rooms depends on ventilation, sub-soil emanation and the housed materials. The use of internal wall coverings such as plaster, distemper and white washing may reduce the radon emanation inside the rooms. The use of paints on walls is the best for reducing the radon concentration inside the rooms. (author). 11 refs

  1. Enhancements of the memory margin and the stability of an organic bistable device due to a graphene oxide:mica nanocomposite sandwiched between two polymer (9-vinylcarbazole) buffer layers

    Science.gov (United States)

    Kim, Woo Kyum; Wu, Chaoxing; Lee, Dea Uk; Kim, Hyoun Woo; Kim, Tae Whan

    2018-01-01

    Current-voltage (I-V) curves for the Al/polymer (9-vinylcarbazole) (PVK)/graphene oxide (GO):mica/PVK/indium-tin oxide (ITO) devices at 300 K showed a current bistability with a maximum high conductivity (ON)/low conductivity (OFF) ratio of 2 × 104, which was approximately 10 times larger than that of the device without a PVK layer. The endurance number of ON/OFF switchings for the Al/PVK/GO:mica/PVK/ITO device was 1 × 102 cycles, which was 20 times larger than that for the Al/GO:mica/ITO device. The ;erase; voltages were distributed between 2.3 and 3 V, and the ;write; voltages were distributed between -1.2 and -0.5 V. The retention time for the Al/PVK/GO:mica/PVK/ITO device was above 1 × 104 s, indicative of the memory stability of the device. The carrier transport mechanisms occurring in the Al/PVK/GO:mica/PVK/ITO and the Al/GO:mica/ITO devices are described on the basis of the I-V results and the energy band diagrams.

  2. Nuclear tracks in CR-39 produced by carbon, oxygen, aluminium and titanium ions.

    Science.gov (United States)

    Rickards, J; Romo, V; Golzarri, J I; Espinosa, G

    2002-01-01

    This work describes the response of CR-39 (allyl diglycol polycarbonate) to different ions (C, O, Al and Ti) produced by the Instituto de Fisica 3 MV 9SDH-2 Pelletron accelerator and backscattered from a thin Au film on a C support. The ion energies were chosen in series such that the ranges of the different ions in the detector were 2, 3, 4, 5, 6, 7 and 8 microm respectively for each series. Once exposed, the detectors were etched with a solution of 6.25 M KOH at 60 degrees C, and the reading was carried out using a digital image analysis system. An analysis of the measured track diameters of all the types of ions indicates that, for a given range, track kinetics are independent of type of ion, energy and stopping power.

  3. Surface stabilized GMR nanorods of silver coated CrO2 synthesized via a polymer complex at ambient pressure

    International Nuclear Information System (INIS)

    Biswas, S.; Singh, G.P.; Ram, S.; Fecht, H.-J.

    2013-01-01

    Stable anisotropic nanorods of surface modified CrO 2 (∼18 nm diameter) with a correlated diamagnetic layer (2–3 nm thickness) of silver efficiently tailors useful magnetic and magnetoresistance (MR) properties. Essentially, it involves a core-shell structure that is developed by displacing part of Cr 4+ ions by Ag atoms on the CrO 2 surface (topotactic surface layer) via an etching reaction of a CrO 2 -polymer complex with Ag + ions in hot water followed by heating the dried sample at 300–400 °C in air. The stable Ag-layer so obtained in the form of a shell protects CrO 2 such that it no longer converts to Cr 2 O 3 in ambient pressure during the processing. X-ray diffractogram of the Rutile type tetragonal CrO 2 structure (lattice parameters a=0.4429 nm and c=0.2950 nm) includes weak peaks of a minority phase of an fcc-Ag (a=0.4086 nm). The silver surface layer, which manifests itself in a doublet of the 3d 5/2 and 3d 3/2 X-ray photoelectron bands of binding energies 368.46 eV and 374.48 eV, respectively, suppresses almost all Cr bands to appear in a measurable intensity. The sample exhibits a distinctly enhanced MR-value, e.g., (−) 7.6% at 77 K, than reported values in compacted CrO 2 powders or composites. Such a large MR-value in the Coulomb blockade regime ( 2 nanorods. - Highlights: • Synthesis and structural studies of a novel GMR material of Ag coated CrO 2 . • Tailoring useful GMR property in CrO 2 nanorods of controlled shape and anisotropy. • Enhanced GMR is explained in correlation to the surface structure of CrO 2 nanorods

  4. Comparison of the influence of polyaspartic acid and polylysine functional groups on the adsorption at the Cr2O3-Aqueous polymer solution interface

    Science.gov (United States)

    Ostolska, Iwona; Wiśniewska, Małgorzata

    2014-08-01

    Polyamino acids are a group of synthesized polymers obtained by polymerization of a given kind of amino acid monomer. Because of high biodegradability of this class of polymers, they can be used as flocculation or stabilization agents in the environmental aspects. Therefore determination of their influence on the stability of the aqueous suspension of metal oxides is important. An influence of different functional groups of polyamino acids, their molecular weight and concentration on the adsorption at the chromium (III) oxide (Cr2O3)-aqueous solution interface was determined. Experiments were carried out for four values of solution pH varying from 3 to 10 (3, 4, 7.6 and 10, respectively). Two polymers were used: anionic polyaspartic acid (ASP) of 6800 and 27,000 as well as polylysine (LYS) of 4900 and 33,000 molecular weights. Changes of surface charge density of colloidal Cr2O3 in the presence and in the absence of macromolecular substances were determined using potentiometric titration. In these studies the influence of the concentration and molecular weight of the ionic polymers on the pHpzc value was determined. Additionally, due to the lack of appropriate literature data, potentiometric titration of the selected polymers was performed to determine pKa values.

  5. Study of α-energy discrimination in CR-39 track etch detectors for use as a radon/thoron dosemeter

    International Nuclear Information System (INIS)

    Kandaiya, S.; Al-Najjar, S.A.R.; Piesch, E.

    1988-01-01

    The properties of CR 39 nuclear track detectors were evaluated for their α-energy discrimination up to 8.77 MeV using a combination of chemical-electrochemical track revealing techniques. Using three field strengths, α-energy discrimination by ECE track diameter and track density as a function of chemical pre-etching time were studied. α-energy spectra using different irradiation geometries were then evaluated using the optimum conditions and then compared with those obtained form other techniques. (author)

  6. The etching property of the surface of CR-39 and the track core radius of fission fragment

    CERN Document Server

    Mineyama, D; Yamauchi, T; Oda, K; El-Rahman, A

    2002-01-01

    The etch pits of fission fragments in CR-39 detector have been observed carefully using an atomic force microscope (AFM) after extremely short chemical etching in stirred 6N KOH solution kept at 70degC. It was found that there existed a thin layer where the bulk etch rate is relativity from large the etch-pit growth curve for the etching duration between 10 and 1800 seconds. The track core radius of fission fragment was evaluated to be about 6 nm from the extrapolation of the growth curve in a thinner region. (author)

  7. Differences between tethered polyelectrolyte chains adsorbed onto bare mica and hydrophobically modified mica, comparison with theory.

    Science.gov (United States)

    Balastre, Marc; Tamashiro, Mario N.; Hernandez, Ernesto; Pincus, Philip; Tirrell, Matthew

    2001-03-01

    End-grafted polymers generated from the adsorption of asymmetric diblock copolymers on solid surface play an important role in many areas of science and technology. While the small insoluble block acts as an anchor, the charged soluble block confers useful properties to the surface. This study looks at tethered layers of poly(styrene sulfonate)/poly(t-butyl styrene) (PtBS-PSS) adsorbed on both mica (hydrophilic) and octadecyltriethoxysilane (OTE) modified mica (hydrophobic). Normal compressing forces at two different constant grafting densities (bare and modified mica) were measured with the surface force apparatus and compared with theoretical prediction. The effect of salt concentration (Cs) upon the thickness of the self-assembled layers (Lo) was measured in each case. For adsorption of diblock copolymers onto OTE the resulting scaling relationship is much closer to the brush theory, Lo Cs-1/3. This result suggests that the adsorbed amount on mica is not high enough to form a brush.

  8. Surface stabilized GMR nanorods of silver coated CrO2 synthesized via a polymer complex at ambient pressure

    Science.gov (United States)

    Biswas, S.; Singh, G. P.; Ram, S.; Fecht, H.-J.

    2013-08-01

    Stable anisotropic nanorods of surface modified CrO2 (˜18 nm diameter) with a correlated diamagnetic layer (2-3 nm thickness) of silver efficiently tailors useful magnetic and magnetoresistance (MR) properties. Essentially, it involves a core-shell structure that is developed by displacing part of Cr4+ ions by Ag atoms on the CrO2 surface (topotactic surface layer) via an etching reaction of a CrO2-polymer complex with Ag+ ions in hot water followed by heating the dried sample at 300-400 °C in air. The stable Ag-layer so obtained in the form of a shell protects CrO2 such that it no longer converts to Cr2O3 in ambient pressure during the processing. X-ray diffractogram of the Rutile type tetragonal CrO2 structure (lattice parameters a=0.4429 nm and c=0.2950 nm) includes weak peaks of a minority phase of an fcc-Ag (a=0.4086 nm). The silver surface layer, which manifests itself in a doublet of the 3d5/2 and 3d3/2 X-ray photoelectron bands of binding energies 368.46 eV and 374.48 eV, respectively, suppresses almost all Cr bands to appear in a measurable intensity. The sample exhibits a distinctly enhanced MR-value, e.g., (-) 7.6% at 77 K, than reported values in compacted CrO2 powders or composites. Such a large MR-value in the Coulomb blockade regime (<100 K) arises not only due to the suppressed spin flipping at low temperature but also from a spin dependent co-tunneling through an interlinked structure of silver and silver coated CrO2 nanorods.

  9. Interaction mean free path measurements for relativistic heavy ion fragments using CR39 plastic track detectors

    International Nuclear Information System (INIS)

    Drechsel, H.; Brechtmann, C.; Dreute, J.; Sonntag, S.; Trakowski, W.; Beer, J.; Heinrich, W.

    1984-01-01

    This paper describes an experiment measuring the interaction mean free paths for charge changing nuclear collisions of relativistic heavy ion fragments. We use a stack of CR39 plastic nuclear track detectors that was irradiated with 1.8 GeV/nucleon 40 Ar ions at the Berkeley Bevalac. About 1.5 x 10 7 etch cones were measured in this experiment using an automatic measuring system. By tracing the etch cones over successive plastic foils the particle trajectories in the stack were reconstructed. For 14185 trajectories with 6444 nuclear collisions of fragments with charge 9-15 the interaction mean free path in the plastic was determined. (orig.)

  10. Crédito pecuário a mulheres de Moçambique: dinâmicas sociais de gênero

    Directory of Open Access Journals (Sweden)

    Maria Henrique Cândido

    2010-11-01

    Full Text Available O objetivo principal deste estudo foi conhecer e compreender os fatores que influenciaram as mulheres rurais do Posto Administrativo de Changalane, ao Sul de Maputo – Moçambique, a optarem pelo crédito pecuário e o significado social do novo papel socioeconômico por elas assumido na Comunidade sob influência da Associação Moçambicana para o Desenvolvimento da Mulher Rural (AMRU. Sustenta-se no gênero como categoria analítica. Trata-se de uma pesquisa qualitativa na perspectiva investigativa exploratória. Centra-se na constituição das mulheres rurais como beneficiárias do crédito pecuário. Essa nova atividade despertou a comunidade para novas formas de produção e relacionamento sociofamiliar, possibilitando o estabelecimento de novas e mais igualitárias relações entre os sexos. Foram identificadas mudanças nas relações sociais e familiares nas unidades produtivas na Comunidade, decorrentes dessa nova modalidade de crédito às mulheres. A estrutura de relações sociais e de gênero foi questionada, favorecida pela estratégia de Educação Cívica e capacitação socioprofissional proposta pela AMRU. Identificou-se a inclusão da mulher, até então “invisível”, como um segmento importante na produção de riquezas, assim como no espaço da cidadania, na direção da justiça social e promoção da igualdade entre os sexos. Discute-se as repercussões dessa atividade na dinâmica das relações matrimoniais que influenciaram a valorização e autoestima das mulheres no plano econômico e social e que culminaram com a aquisição de prestígio social. Mudanças vislumbradas na dinâmica familiar, a partir de elementos materiais e simbólicos, compõem, atualmente, a vida dessas mulheres. Salienta-se, também, a relevância da “nova identidade” proporcionada e geradora de novas práticas sociais na conformação do rural e da Agricultura Familiar dentro dessa Comunidade.

  11. New approach of modeling charged particles track development in CR-39 detectors

    International Nuclear Information System (INIS)

    Azooz, A.A.; Hermsdorf, D.; Al-Jubbori, M.A.

    2013-01-01

    In this work, previous modeling of protons and alpha particles track length development in CR-39 solid state nuclear track detectors SSNTD is modified and further extended. The extension involved the accommodation of heavier ions into the model. These ions include deuteron, lithium, boron, carbon, nitrogen and oxygen ions. The new modeling does not contain any case sensitive free fitting parameters. Model calculation results are found to be in good agreement with both experimental data and SRIM software range energy dependence predictions. The access to a single unified and differentiable track length development equation results in the ability to obtain direct results for track etching rates. - Highlights: • New modeling of ions track length evolution measured by different authors. • Ions considered are p, d, α, Li, B, C, N, O. • Equations obtained to describe L(t) and etch rate for all ions at wide energy range. • Equations obtained do not involve any free fitting parameters. • Ions range values obtained compare well with results of SRIM software

  12. Neuropatía Endémica Crónica Asociada con Virus Humano Linfotrófico

    Directory of Open Access Journals (Sweden)

    Jaime G. Gómez

    1990-04-01

    Full Text Available

    Diagnóstico y Tratamiento de la Neuropatía Endémica Crónica Asociada con Virus Humano Linfotrófico de Células T, Tipo I (HTLV-l

    El propósito del presente artículo es haccr una breve revisión del estado actual de la Neuropatía endémica crónica asociada con el Virus Humano Linfotrópico de Celulas T-tipo L conocido por la sigla inglesa HTLV-I y presentar el primer caso tratado con éxito. logrando posiblemente la curación de la enfermedad.

    La Neuropatía endémica asociada con el Virus Humano Linfotrópico de Celulas T-tipo 1, (NEC-HTL V-1 es una enfermedad lentamente progresiva caracterizada por debilidad de las extremidades inferiores, trastornos de los esfínteres, alteraciones subjetivas de la sensibilidad, asociadas con la presencia de anticuerpos contra el HTL V-I en la sangre y en el líquido cefalorraquídeo.

    La enfermedad fue descrita por primera vez hace casi cien años en Jamaica por Strachnan (1897, Cruishank publicó en 1956 el cuadro patológico en el cual se encuentra degeneración de las vías piramidales, desmielinización, proliferación capilar con acúmulos de linfocitos alrededor de los vasos sanguineos. Maní y col informaron una enfermedad similar en el Sur de la India (1969. En 1981 Zaninovich encontró una zona endémica en la costa del Pacífico de Colombia y gracias a su interes consiguió apoyo de la Organización Mundial de la Salud y del Instituto Nacional de Salud de los Estados Unidos para adelantar los estudios sobre esta endemia.

    En 1985 Gessain y col hallaron por primera vez en Martinfca anticuerpos contra el HTL V-1 en una alta proporción de pacientes con la enfermedad que denominaron Paraparesia Espástica Tropical.

    El Virus Humano Linfotrópico de Celulas T o HTL V-1, pertenece a la familia de los Retrovirus, caracterizados por poseer una enzima denominada Transcriptasa Invertida (“Reverse Transcriptase”. Fue descubierto por Gallo

  13. Calibration of thermal neutron detection compound BN-1 and CR-39 in the exposure room of Triga Reactor in Ljubljana

    International Nuclear Information System (INIS)

    Kristof, E.; Ilic, R.; Skvarc, J.; Dijanosic, R.

    1994-01-01

    Description of determination of thermal neutron fluences in the range from 1.E+02 to 1.E+12 cm -2 for calibration of the neutron sensitive compound consisting of the neutron converter BN-1 and charged particle detector CR-39 is given. The method employs two proportional BF3 detectors supplemented by a Ge(Li) gamma spectometer utilizing gold foils. The results of the measurements are also presented. (author)

  14. Background tracks in CR-39 SSNTD sheets: their control and prediction through an interplay of etching parameters

    International Nuclear Information System (INIS)

    Bhagwat, A.M.; Naik, G.R.; Thampan, S.; Rudran, K.; Joshi, V.B.; Iyer, M.R.

    1992-01-01

    High sensitivity of CR-39 film in turn leads to higher and variable background track-densities. A two-step etching process, each consisting of CE and ECE, is therefore suggested which permits not only partial freezing of the background but also allows to know its level. The procedure identifies bad pieces with scratches and determines the minimum detection limit (MDL) of each film individually. Activities as low as 0.2 mBq (∼ 5 x 10 -15 curies) can thus be measured with low background films for exposure periods of 7-10 days (exposure is carried out after first processing). (author)

  15. Timing and processes for exhumation of HP/LT rocks of the southern Brooks Range (AK): Insight from combined geochemistry and 40Ar/39Ar thermochronology of white mica

    Science.gov (United States)

    O'Brien, T.; Miller, E. L.; Grove, M. J.; Hayden, L. A.

    2015-12-01

    The obduction of an island arc onto the Arctic Alaska continental margin in the Jura-Cretaceous led to southward subduction of continental crust and high-pressure/low-temperature (HP/LT) epidote-blueschist facies metamorphism in the southern Brooks Range (BR). A regionally developed greenschist facies normal-sense shear zone system along the southern margin of the BR suggests that extensional faulting had an influential role in the exhumation of the metamorphic core. To better constrain the exhumation history of the metamorphic core of the BR, samples were collected from a N-S transect through the metamorphic core of the orogen. Electron microprobe (EMP) analyses of white micas reveal that they are composed of phengite (Si > 3.0 pfu) or a combination of phengite + paragonite. Si-content of phengites reveal a southward increase in Si from 3.1 to 3.4 pfu (corresponding to an increase in pressure). Si-contents in higher-P phengites are scattered, reflecting subsequent muscovite growth. The Si trend is matched by a southward increase in the 40Ar/39Ar total gas ages of white micas. Phengite from the north are characterized by younger ages (~115 Ma) and flatter 40Ar/39Ar spectra. Farther south, phengites and paragonites yield older 40Ar/39Ar ages. These samples yield convex, staircase 40Ar/39Ar spectra that initiate ~115-120 Ma and flatten-out ~130-138 Ma. Modeling using MacArgon proposes that an initial cooling of HP/LT metamorphism occurred ~130-138 Ma, recorded in the high-Si phengites and paragonites. Following initial cooling, modeling suggests HP/LT rocks stalled in the greenschist facies field before subsequent exhumation, resulting in the staircase 40Ar/39Ar spectra. Flatter 40Ar/39Ar spectra recorded by the northern samples and modeling of 40Ar/39Ar results from the southern samples suggest that these rocks from metamorphic core of the BR were exhumed to temperatures < 300°C by ~115 Ma.

  16. On the X-ray reflectivity by poly allyl diglycol carbonate (PADC)

    International Nuclear Information System (INIS)

    Ghazaly, M. El

    2011-01-01

    X-ray reflectivity via the poly allyl diglycol carbonate (CR-39 polymer sheet) was investigated. X-ray reflectivity was measured for a pristine and a chemically etched CR-39 detector in 6.25N NaOH at (70 ± 0.5) .deg. C for different durations. Far from the spectral peak, the reflectivity of the CR-39 polymer sheet has a wide peak at 2θ = 20.1 .deg. , and its intensity is decreased by increasing the etching time. Moreover, the integrated counts under the peaks, C(t e ), vary linearly as a function of the etching time t e . Data are fitted using a linear function C(t e ) = A+Bt e , with fitting parameters A = (3271 ± 170) and B = (- 960 ± 84). The reflectivity deterioration is attributed to the increase of CR-39 surface's roughness due to the chemical etching. The rocking curves of X-ray reflectivity were measured for a pristine and an etched CR-39 polymer sheet. Specular reflections are observed, as well as Yoneda wings, which broaden and move away from the specular reflections due to the increase in the CR-39 surface's roughness.

  17. Interaction of low-intensity nuclear radiation dose with the human blood: Using the new technique of CR-39NTDs for an in vitro study

    International Nuclear Information System (INIS)

    Ismail, Asaad H.; Jaafar, Mohamad S.

    2011-01-01

    Complete blood counts were analyzed for 30 samples of human blood with radiation dose rate ranging between 10 and 41 μSv/h using a Radium-226 source with different time of exposure. A new technique involving a nuclear track detector type CR-39(CR-39 NTDs) was used to estimate the alpha particle density incident on the blood samples. The results show that the ranges of alpha particle in blood samples and on the surface of CR-39NTDs vary exponentially with energy of alpha particles. This depends on the restricted energy loss and target density. Changes in the blood components due to irradiation occurred for different durations of irradiation, and the duration of irradiation that influenced the blood samples in this study was 6 min. The change in red blood cell (RBC) was negligible, so it is less affected than other blood components. In addition, most changes in the blood contents began at a low radiation dose (10.38-13.41 μSv/h). For the doses 13.41-21.77 μSv/h, platelet (PLT) counts increased rapidly and adversely with the RBC and white blood cell (WBC) due to chromosomal aberration. Besides, rapid PLT count reduction rapidly at high dose (42.1 μSv h) causes thrombocytopenia; in contrast, WBC increased, which is an indication of cancer caused due to increase in alpha particle dose. Generally, our results are in agreement with the essentials of blood content and the principles of biological radiation interaction.

  18. Calibration of CR-39 plastic detectors in various modes and radon measurement in the north-western region of Bangladesh

    International Nuclear Information System (INIS)

    Islam, G.S.; Islam, M.A.; Haque, A.K.F.

    1998-04-01

    Solid State track detectors have been extensively used for the measurement of time integrated radon levels in dwellings under different conditions. The CR-39 plastic detectors were calibrated for bare as well as cup with membrane mode, along with a mono dispersal aerosol 0.2μm in size in an exposure chamber, to find the relationship between track densities and the radon concentration as well as potential alpha energy concentration (WL) of radon. Measurement of the indoor radon and radon daughter concentrations were performed in houses in the north-western region of Bangladesh. In total 163 detectors were placed for measurement of indoor radon activities and 230 detectors for measurement of radon daughter concentrations. To study the underground radon activity, 114 CR-39 detectors in cylinders were used. The indoor radon activity in Naogaon was, in general, found to be higher than that in Rajshahi. The working levels in the mud-built houses were greater than that in brick-built houses. The underground radon activity of Naogaon was found to be 6 times higher than that of Rajshahi. No direct correlation was observed between the underground and indoor radon activity. The average values of radon activity and the working level for the north-western zone of Bangladesh are found to be 91 Bq. m -3 and 16 mWL respectively. (author)

  19. Usage of an interactive image analysis system for studying various parameters of etched tracks in CR-39 and Makrofol E

    International Nuclear Information System (INIS)

    Abu-Jarad, F.; Islam, M.A.; Que, A.

    1991-01-01

    An Automated Interactive Built Analysis System (IBAS) is being used to analyze the alpha and fission fragment tracks in CR-39 and Makrofol E detectors. It primarily consists of a control computer (IBAS1) and an image processor (IBAS2). The system is used for counting the nuclear tracks, measuring their areas, diameters, statistics and displaying the frequency distribution of their sizes. All information can be printed out or stored on floppy disks. (author)

  20. CR-39 nuclear track detector application for the diagnostics of low energy high power ion beams

    Energy Technology Data Exchange (ETDEWEB)

    Opekounov, M S; Pechenkin, S A; Remnev, G E [Nuclear Physics Institute, Tomsk (Russian Federation); Ivonin, I V [Siberian Physical-Technical Institute, Tomsk (Russian Federation)

    1997-12-31

    The results of investigation of the spectral composition of ion beams generated by the magneto-insulated ion diode of the MUK-M and TEMP accelerators. The energy and mass characteristics of the accelerated ion beam were determined by a Thomson spectrometer with a CR-39 plate detector (MOM - Atomki Nuclear Track Detector, Type MA-ND/p). The accelerated ion energy was from 40 to 240 keV. The ion current density range was from 1 to 10 A/cm{sup 2}. The mass composition contained hydrogen, nitrogen, carbon and aluminum ions. The individual track analysis showed the track form, depth and diameter in dependence on the ion mass and energy. (author). 2 figs., 5 refs.

  1. Adsorption of Cr (III from aqueous solution by two forms of a superabsorbant polymer : parametric study and effect of activation mode

    Directory of Open Access Journals (Sweden)

    Ouass A.

    2018-01-01

    Full Text Available The adsorption of chromium ions Cr3+ using two forms of a superabsorbant polymer PANa from aqueous solution was investigated. On one hand the equilibrium pH with the distilled water and the pH of point of zero charge have been studied in order to characterize the acid-base behavior of both of PANa forms. On the other hand, the effect of contact time between PANa and the metallic solution and stirring speed of aqueous solution on the adsorption rate were established to highlight the importance of PANa as an efficient adsorbent of chromium ions Cr3+.

  2. Measurement of track opening contours of oblique incident 4He and 7Li-ions in CR-39: Relevance for calculation of track formation parameters

    International Nuclear Information System (INIS)

    Hermsdorf, D.; Reichelt, U.

    2010-01-01

    Solid State Nuclear Track Detectors (SSNTD) irradiated in realistic radiation fields exhibits after chemical etching very complex track images resulting from different species of particles and their energy spectra and randomly distributed angles of incidence or emission. Reading out such an etched detector surface with a light microscope, quite different track opening contours are observed. Beside the number of tracks, typically their major and minor axes are measured. In this work following problems arising from such experimental situations will be investigated: ·the measurement of track contour parameters for oblique incident 4 He and 7 Li-ions of different energies and angles in CR-39 detectors ·the theoretical description of the angular variation of both axes. ·the possibility to extract physical and spectroscopic information from major and minor track axes. This analysis is based on an intensive experimental program and the comprehensive study of theoretical models available for description of track revealing processes in CR-39.

  3. Fragmentation cross section measurements of iron projectiles using CR-39 plastic nuclear track detectors

    CERN Document Server

    Flesch, F; Huentrup, G; Roecher, H; Streibel, T; Winkel, E; Heinrich, W

    1999-01-01

    For long term space missions in which larger radiation doses are accumulated it is necessary to improve the precision of models predicting the space radiation environment. Different models are available to determine the flux of cosmic ray heavy ions behind shielding material. The accuracy of these predictions depends on the knowledge of the fragmentation cross sections, especially at energies of several hundred MeV/nucleon, where the particle flux is at a maximum and especially for those particles with high LET, i.e. iron nuclei. We have measured fragmentation cross sections of sup 5 sup 6 Fe projectiles at beam energies of 700 and 1700 A MeV using experimental set-ups with plastic nuclear track detectors. In this paper we describe the experimental technique to study the fragmentation reactions of sup 5 sup 6 Fe projectiles using CR-39 plastic nuclear track detectors. Results for different targets are presented.

  4. Change of Cr-39(DOP) track detector response as a result of space exposure

    International Nuclear Information System (INIS)

    Yadav, J.S.; Singh, R.K.

    1990-01-01

    The response functions for CR-39(DOP) plastic track detectors are calculated, using the simplex method for nonlinear least squares fit, from experimental data obtained from accelerator beams as well as space exposure. The average detector sensitivity is reduced by over 30% in the case of space exposure. The average charge shift for the oxygen group is one charge unit, and it increases with particle charge. The effect decreases with restricted energy loss, which is contrary to that observed in the registration temperature effect. We have discussed various environmental parameters which may produce the observed effect. The registration temperature effect may account for the observed effect (within the errors) for the worst case (temperature) analysis. However, a more reasonable estimate suggests that both the registration temperature as well as pressure during exposure contribute to the observed effect. To discriminate between the separate contributions, further experimental data is needed. (author)

  5. Auto-counting of high density overlapping tracks and neutron spectrum measurement using CR-39 detectors and in-house image analysis program

    International Nuclear Information System (INIS)

    Paul, Sabyasachi; Tripathy, S.P.; Sahoo, G.S.; Joshi, D.S.; Bandyopadhyay, T.

    2014-01-01

    An effort is made in this work to overcome the difficulty of counting highly dense and overlapping tracks in solid polymeric track detectors (SPTD) such as CR-39. A program is developed to automatically count the track density which is found to be faster and more precise compared to other commonly used image analysing software. The results obtained by the present methodology are compared with those obtained using other software. (author)

  6. Alpha particle spectroscopy for CR-39 detector utilizing matrix of energy equations

    Energy Technology Data Exchange (ETDEWEB)

    Awad, E.M. [Department of General Sciences, Yanbu Industrial College, PO Box 30436, Madinat Yanbu Al-Sinaiya (Saudi Arabia); Physics Department, Faculty of Science, Menofia University, Shebin El-Koom (Egypt)], E-mail: ayawad@yahoo.com; Soliman, A.A. [Department of Mathematics, Faculty of Education (AL-Arish), Suez Canal University, AL-Arish 45111 (Egypt); Department of Mathematics, Teacher' s College (Bisha), King Khalid University, Bisha, PO Box 551 (Saudi Arabia)], E-mail: asoliman_99@yahoo.com; Rammah, Y.S. [Physics Department, Faculty of Science, Menofia University, Shebin El-Koom (Egypt)

    2007-10-01

    A method for determining alpha-particle energy using CR-39 detector by utilizing matrix of energy equation was described. The matrix was composed from two axes; the track minor axis (m) and diameter of etched out track end (d) axis of some selected elliptical tracks. The energy E in (m,d) coordinate was approximated by matrix of energy equations given by: E{sub k}={sigma}{sub i,j=0}{sup 2}a{sub ij}d{sub k}{sup i}m{sub k}{sup j}, which was identified using two different approaches. First, i and j were treated as power exponents for d and m. The adjusting parameters values a{sub ij} were obtained and the energy of a given track was deduced directly from it. Second, i and j were treated as indices of some chosen tracks that were fitted to obtain iso-energy curves that were superimposed on m-d scatter plot as calibration curves. The energy between any two successive iso-energy curves in this case was assumed varied linearly with d for a given m. The energy matrix in both cases was solved numerically. Results of the two approaches were compared.

  7. Application of CR-39 microfilm for rapid discrimination between alpha-particle sources

    Energy Technology Data Exchange (ETDEWEB)

    Dwaikat, Nidal; Al-karmi, Anan M. [Dept. of Physics, King Fahd University of Petroleum and Minerals, Dhahran (Saudi Arabia)

    2017-06-15

    This work presents a new technique for discriminating between alpha particles of different energy levels. In a first study, two groups of alpha particles emitted from radium-226 and americium-241 sources were successfully separated using a CR-39 microfilm of appropriate thickness. This thickness was adjusted by chemical etching before and after irradiation so that lower-energy particles were stopped within the detector, while higher-energy particles were revealed on the back side of the detector. The number of tracks on the front side of the microfilm represented all alpha particles incident on that side from the two sources. However, the number of tracks on the back side of the microfilm represented only the long-range alpha particles of higher energy that arrived at that side. Therefore, by subtracting the number of tracks on the back side from the number of tracks on the front side, one could easily determine the number of tracks for the short-range alpha particles of lower energy that remained embedded in the microfilm. Discrimination of the two energy levels is thus achieved in a simple, fast, and reliable process.

  8. Malogro da fortuna: política de créditos, hipotecas e Caixas Econômicas na década de 1930

    Directory of Open Access Journals (Sweden)

    Renato Leite Marcondes

    2016-02-01

    Full Text Available A Grande Depressão da década de 1930 conduziu o governo brasileiro a modificar a legislação sobre o sistema financeiro, como a lei da usura e do reajustamento econômico. Tais mudanças ajudaram a evitar um aprofundamento da Grande Depressão, porém não permitiram a recuperação do crédito. Verificamos as mudanças do crédito por meio do mercado de hipotecas e da participação dos bancos públicos, principalmente as Caixas Econômicas. Essa instituição expandiu significativamente sua atuação, tanto na captação de depósitos como principalmente na concessão de empréstimos. Notamos uma política anticíclica no mercado financeiro, principalmente por meio de instituições públicas, como os empréstimos hipotecários das Caixas.

  9. Dose-rate effects on the bulk etch-rate of CR-39 track detector exposed to low-LET radiations

    CERN Document Server

    Yamauchi, T; Oda, K; Ikeda, T; Honda, Y; Tagawa, S

    1999-01-01

    The effect of gamma-rays and pulsed electrons has been investigated on the bulk etch rate of CR-39 detector at doses up to 100 kGy under various dose-rate between 0.0044 and 35.0 Gy/s. The bulk etch rate increased exponentially with the dose at every examined dose-rates. It was reveled to be strongly depend on the dose-rate: the bulk etch rate was decreased with increasing dose-rate at the same total dose. A primitive model was proposed to explain the dose-rate effect in which oxygen dissolved was assumed to dominate the damage formation process.

  10. Bases celulares e bioquímicas da doença pulmonar obstrutiva crônica Cellular and biochemical bases of chronic obstructive pulmonary disease

    Directory of Open Access Journals (Sweden)

    Rogério Rufino

    2006-06-01

    Full Text Available A doença pulmonar obstrutiva crônica é uma doença inflamatória com participação ativa de macrófagos, neutrófilos e linfócitos CD8+ em sua patogênese, associada a estímulos oxidantes diretos das estruturas pulmonares, que desencadeiam reações bioquímicas, levando a progressiva desorganização das pequenas vias aéreas e ao remodelamento estrutural não reversível. A liberação de substâncias provenientes das células recrutadas e do estresse oxidativo leva ao desequilíbrio inicialmente temporário dos mecanismos de defesa pulmonar. A permanência desse desequilíbrio é uma das chaves da fisiopatogenia atual. Os autores descrevem as alterações celulares e bioquímicas da doença pulmonar obstrutiva crônica.Chronic obstructive pulmonary disease is an inflammatory disease. Together with oxidant stimuli, which directly affect lung structures, macrophages, neutrophils and CD8+ lymphocytes actively participate in the pathogenesis of the disease and promote biochemical reactions that result in progressive alteration of the upper airways and irreversible lung remodeling. The release of substances promoted by inflammatory cell recruitment and by oxidative stress lead to a temporary imbalance in the pulmonary defense mechanisms. Understanding the long-term maintenance of this imbalance is key to understanding the current physiopathology of the disease. The present study explores the cellular and molecular alterations seen in chronic obstructive pulmonary disease.

  11. Energy spectrum of iron nuclei measured inside the MIR space craft using CR-39 track detectors

    International Nuclear Information System (INIS)

    Guenther, W.; Leugner, D.; Becker, E.; Flesch, F.; Heinrich, W.; Huentrup, G.; Reitz, G.; Roecher, H.; Streibel, T.

    1999-01-01

    We have exposed stacks of CR-39 plastic nuclear track detectors inside the MIR space craft during the EUROMIR95 space mission for almost 6 months. Over this long period a large number of tracks of high LET events was accumulated in the detector foils. The etching and measuring conditions for this experiment were optimized to detect tracks of stopping iron nuclei. We found 185 stopping iron nuclei inside the stack and identified their trajectories through the material of the experiment. Based on the energy-range relation the energy at the surface of the stack was determined. These particles allow the determination of the low energy part of the spectrum of iron nuclei behind shielding material inside the MIR station

  12. Application of spectroscopic methods to the study of ionizing radiation effects in polymers

    International Nuclear Information System (INIS)

    Jimenez P, G.

    1995-01-01

    In general the interaction of ionizing radiation with polymers generates physic-chemical changes. Aiming to quantity these changes, three spectroscopic analytical techniques were used (UV, IR and EPR) and the chemical corrosion technique was used for three DSTN (CR39, Lexan and Makrofol) which were exposed to two radiation types: electrons and gammas. The effects of radiation are compared. Also a correlation between the UV and Vg results in function of dose is presented. The possible causes of the increase in chemical corrosion are discussed. (Author)

  13. Track Detection Technique Using CR-39 for Determining Depleted Uranium in Biological Specimens

    International Nuclear Information System (INIS)

    Murbat, S.M.

    2013-01-01

    Track detecting technique using CR-39 track detector has been implemented for determining depleted uranium concentration in biological specimens (tissues, bones, and blood) of patients infected with cancer diseases. Results were compared with specimens of patients infected with conventional diseases (noncancerous). Specimens were collected from middle and south of Iraq have been contaminated with depleted uranium in the Gulf war in 1991. Results show that this technique is efficient for determining depleted uranium concentration in biological specimens. It was found that all studies samples determine for patients infected with cancer diseases contain a high concentration of depleted uranium (more than the international standard) comparing with noncancerous diseases. Moreover, it was found that persons infected with Leukemia show more sensitive to uranium concentrations to induce the diseases (66-202 ppb), while (116- 1910 ppb) concentrations were needed for inducing cancer diseases in organs and tissues. Result confirmed the correlation between cancerous diseases and the munitions made of depleted uranium used in the Gulf war in 1991 leads to contaminate the Iraqi environment and causes a high risk against people in Iraq.

  14. Reseña del libro "Prácticas de las bibliotecas universitarias argentinas : reflexiones críticas en el contexto de la comunicación académica y sus representaciones en la web" de M. Patalano

    Directory of Open Access Journals (Sweden)

    Susana Soto

    2013-11-01

    Full Text Available Reseña del libro "Prácticas de las bibliotecas universitarias argentinas : reflexiones críticas en el contexto de la comunicación académica y sus representaciones en la web" de Mercedes Patalano

  15. Measurement of target fragments produced by 160 MeV proton beam in aluminum and polyethylene with CR-39 plastic nuclear track detectors

    Czech Academy of Sciences Publication Activity Database

    Ambrožová, Iva; Yasuda, N.; Kodaira, S.; Sihver, L.

    2014-01-01

    Roč. 64, MAY (2014), s. 29-34 ISSN 1350-4487 R&D Projects: GA AV ČR KJB100480901; GA AV ČR IAA100480902; GA MŠk LG14004 Institutional support: RVO:61389005 Keywords : target fragments * high-energy protons * Aluminium * Polyethylene * plastic nuclear track detectors * CR-39 Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders Impact factor: 1.213, year: 2014

  16. Tribological performance of polymer composites used in electrical ...

    Indian Academy of Sciences (India)

    engineering applications. ZAFER DEMIR. Anadolu University, Eskisehir, Turkey. MS received 28 December 2011; revised 13 March 2012. Abstract. Sliding wear performance of 20% mica-filled polyamide 6 (PA6 + 20% mica) and 20% short glass fibre- reinforced polysulphone (PSU + 20 GFR) polymer composites used in ...

  17. Reflexiones sobre la importancia de la Crítica de Lucas

    Directory of Open Access Journals (Sweden)

    Mauricio Sánchez Puerta

    2005-04-01

    Full Text Available La crítica de Lucas sostiene que, bajo la hipótesis de expectativas racionales, los parámetros estimados a partir de un modelo econométrico no se mantendrían. La ocurrencia de cambios de política llevaría a los agentes a modificar sus comportamientos, a fin de adecuarse a la nueva realidad. En consecuencia, los modelos econométricos no podrían utilizarse para fines de formulación de políticas económicas. La crítica de Lucas desafió rigurosamente el modo en que el modelado econométrico se utilizaba tradicionalmente como instrumento para la evaluación de políticas económicas y la forma en que se consideraba la política económica. Aunque la importancia empírica de la crítica sigue siendo motivo de debate, ella contribuyó a la imposición de nuevos patrones en el modelado de la interacción entre las reglas de política y las respuestas de los agentes privados.

  18. Assessment of radiation shielding materials for protection of space crews using CR-39 plastic nuclear track detector

    International Nuclear Information System (INIS)

    DeWitt, J.M.; Benton, E.R.; Uchihori, Y.; Yasuda, N.; Benton, E.V.; Frank, A.L.

    2009-01-01

    A significant obstacle to long duration human space exploration such as the establishment of a permanent base on the surface of the Moon or a human mission to Mars is the risk posed by prolonged exposure to space radiation. In order to keep mission costs at acceptable levels while simultaneously minimizing the risk from radiation to space crew health and safety, a judicious use of optimized shielding materials will be required. We have undertaken a comprehensive study using CR-39 plastic nuclear track detector (PNTD) to characterize the radiation shielding properties of a range of materials-both common baseline materials such as Al and polyethylene, and novel multifunctional materials such as carbon composites-at heavy ion accelerators. The study consists of analyzing CR-39 PNTD exposed in front of and behind shielding targets of varying composition and at a number of depths (target thicknesses) relevant to the development and testing of materials for space radiation shielding. Most targets consist of 10 cm x 10 cm slabs of solid materials ranging in thickness from 1 to >30 g/cm 2 . Exposures have been made to beams of C, O, Ne, Si, Ar, and Fe at energies ranging from 290 MeV/amu to 1 GeV/amu at the National Institute of Radiological Sciences HIMAC and the NASA Space Radiation Laboratory (NSRL) at Brookhaven National Laboratory. Analysis of the exposed detectors yields LET spectrum, dose, and dose equivalent as functions of target depth and composition, and incident heavy ion charge, energy, and fluence. Efforts are currently underway to properly weigh and combine these results into a single quantitative estimate of a material's ability to shield space crews from the interplanetary galactic cosmic ray flux.

  19. Surface stabilized GMR nanorods of silver coated CrO{sub 2} synthesized via a polymer complex at ambient pressure

    Energy Technology Data Exchange (ETDEWEB)

    Biswas, S., E-mail: drsomnathbiswas@gmail.com [The LNM Institute of Information Technology, Jaipur-302031 (India); Singh, G.P. [Centre for Nanotechnology, Central University of Jharkhand, Ranchi-835205 (India); Ram, S. [Materials Science Centre, Indian Institute of Technology, Kharagpur-721302 (India); Fecht, H.-J. [Insitut für Micro-und Nanomaterialien, Universität Ulm, Albert Einstein Allee-47, Ulm, D-89081, and Forschungszentrum Karlsruhe, Institute of Nanotechnology, Karlsruhe, D-76021 (Germany)

    2013-08-15

    Stable anisotropic nanorods of surface modified CrO{sub 2} (∼18 nm diameter) with a correlated diamagnetic layer (2–3 nm thickness) of silver efficiently tailors useful magnetic and magnetoresistance (MR) properties. Essentially, it involves a core-shell structure that is developed by displacing part of Cr{sup 4+} ions by Ag atoms on the CrO{sub 2} surface (topotactic surface layer) via an etching reaction of a CrO{sub 2}-polymer complex with Ag{sup +} ions in hot water followed by heating the dried sample at 300–400 °C in air. The stable Ag-layer so obtained in the form of a shell protects CrO{sub 2} such that it no longer converts to Cr{sub 2}O{sub 3} in ambient pressure during the processing. X-ray diffractogram of the Rutile type tetragonal CrO{sub 2} structure (lattice parameters a=0.4429 nm and c=0.2950 nm) includes weak peaks of a minority phase of an fcc-Ag (a=0.4086 nm). The silver surface layer, which manifests itself in a doublet of the 3d{sub 5/2} and 3d{sub 3/2} X-ray photoelectron bands of binding energies 368.46 eV and 374.48 eV, respectively, suppresses almost all Cr bands to appear in a measurable intensity. The sample exhibits a distinctly enhanced MR-value, e.g., (−) 7.6% at 77 K, than reported values in compacted CrO{sub 2} powders or composites. Such a large MR-value in the Coulomb blockade regime (<100 K) arises not only due to the suppressed spin flipping at low temperature but also from a spin dependent co-tunneling through an interlinked structure of silver and silver coated CrO{sub 2} nanorods. - Highlights: • Synthesis and structural studies of a novel GMR material of Ag coated CrO{sub 2}. • Tailoring useful GMR property in CrO{sub 2} nanorods of controlled shape and anisotropy. • Enhanced GMR is explained in correlation to the surface structure of CrO{sub 2} nanorods.

  20. Determination Of Uranium Concentration In Teeth Female Samples Using Fission Tracks In CR-39 From Different Countries

    International Nuclear Information System (INIS)

    Hummadi, S.S

    2010-01-01

    The present study was under taken to measure the uranium concentration in female teeth samples collected from different nationalities.The determination of uranium concentration in these samples has been done by using CR-39 track detector.The nuclear reaction is used as a source of nuclear fission fragments is (n, f) obtained by the bombardment of U-235 with thermal neutrons with flux (5*10 3 n/cm 2 .s) was used from (Am-Be) neutron source.The obtained results show the concentration is ranging from (0.58±0.7ppm) in Oman and Uae to (0.35±0.03ppm)in Iraqi for male, the uranium concentration was the highest in Oman and Uae for female

  1. OBESIDADE EM IDOSOS COM HIPERTENSÃO ARTERIAL SISTÉMICA

    Directory of Open Access Journals (Sweden)

    Maria Alice Rodrigues Mártires

    2013-01-01

    Full Text Available Estudio exploratorio, descriptivo y cuantitativo, realizado en un Centro de Salud en Portugal, cuyos objetivos fueron caracterizar ancianos hipertensos en tratamiento ambulatorio e identificar factores de riesgo cardiovascular asociados a la hipertensión arterial sistémica. La muestra fue constituida por 250 ancianos que aceptaran contestar a un cuestionario estructurado. De los ancianos encuestados, 43,6% presentaban sobrepeso y 39,6% obesidad. Hay que señalar que 69,6% de los ancianos presentaban valores de presión arterial >140/90 mmHg y 50,4% presentaban colesterol total >200 mg/dl. Se concluye que la mayoría de los ancianos no estaban controlados los valores de la presión arterial, así como otros factores de riesgo cardiovascular, destacando la importancia de intervenciones de Enfermería a los ancianos y familiares de forma a encorajar la responsabilidad personal en auto-cuidado para el control de enfermedad crónica y el acceso a los cuidados de Enfermería de calidad con vista a la promoción de un envejecimiento saludable.

  2. Evolution of etched nuclear track profiles of alpha particles in CR-39 by atomic force microscopy

    International Nuclear Information System (INIS)

    Félix-Bautista, R.; Hernández-Hernández, C.; Zendejas-Leal, B.E.; Fragoso, R.; Golzarri, J.I.; Vázquez-López, C.; Espinosa, G.

    2013-01-01

    A series of atomic force microscopy (AFM) images of etched nuclear tracks has been obtained and used to calculate the nuclear track registration sensitivity parameter V(x) = Vt(x)/Vb. Due to the AFM limitations the samples were irradiated normally to the surface, and with energies attenuated in order to include the Bragg peak region in the AFM piezo-scanner z movement range. The simulation of the track profile evolution was then obtained. The different stages of etched nuclear track profiles were rendered. - Highlights: ► Using AFM we reach that Bragg peak region of etched tracks in CR-39. ► The etched track sensitivity V was calculated by data obtained by AFM. ► The evolucion of etched nuclear tracks was simulated by data achieved by AFM

  3. Sulfur-Doped Carbon Nitride Polymers for Photocatalytic Degradation of Organic Pollutant and Reduction of Cr(VI).

    Science.gov (United States)

    Zheng, Yun; Yu, Zihao; Lin, Feng; Guo, Fangsong; Alamry, Khalid A; Taib, Layla A; Asiri, Abdullah M; Wang, Xinchen

    2017-04-01

    As a promising conjugated polymer, binary carbon nitride has attracted extensive attention as a metal-free and visible-light-responsive photocatalyst in the area of photon-involving purification of water and air. Herein, we report sulfur-doped polymeric carbon nitride microrods that are synthesized through thermal polymerization based on trithiocyanuric acid and melamine (TM) supramolecular aggregates. By tuning the polymerization temperature, a series of sulfur-doped carbon nitride microrods are prepared. The degradation of Rhodamine B (RhB) and the reduction of hexavalent chromium Cr(VI) are selected as probe reactions to evaluate the photocatalytic activities. Results show that increasing pyrolysis temperature leads to a large specific surface area, strong visible-light absorption, and accelerated electron-hole separation. Compared to bulk carbon nitride, the highly porous sulfur-doped carbon nitride microrods fabricated at 650 °C exhibit remarkably higher photocatalytic activity for degradation of RhB and reduction of Cr(VI). This work highlights the importance of self-assembly approach and temperature-control strategy in the synthesis of photoactive materials for environmental remediation.

  4. Vida académica de la facultad

    OpenAIRE

    Facultad de Medicina Revista

    1999-01-01

    Enciclopedia Académica sobre el Lenguaje en las Ciencias de la Salud / Convenio con la Universidad de Alcalá de Henares / Libro de Biología / XI Congreso de actualización en Rehabilitación Médica. Dolor crónico, diagnóstico y manejo integral / Primer Congreso Latinoamericano de Estudiantes de Nutrición y Dietética

  5. Caracterización química de la cerámica arqueológica de Cotahuasi mediante análisis por activación neutrónica

    OpenAIRE

    Bedregal, Patricia; Mendoza, Pablo; Ubillús, Marco; Montoya, Eduardo

    2010-01-01

    Se ha determinado las concentraciones de As, Ba, Ce, Co, Cr, Cs, Eu, Fe, Hf, La, Na, Rb, Sb, Sc, Sm, Th, Yb, en 121 fragmentos de cerámicos arqueológicos encontrados en el valle de Cotahuasi, mediante análisis por activación neutrónica instrumental, según el método k-subcero. Se ha comparado los resultados con la composición química elemental de la cerámica Tiwanaku y la cerámica Wari de Ayacucho y Cusco, encontrándose que los grupos de Ayacucho, Cotahuasi, Cusco y Tiwanaku se encuentran sepa...

  6. La gestión económica de los recursos naturales y sus críticos

    Directory of Open Access Journals (Sweden)

    Carlos Mario Gómez

    1998-07-01

    Full Text Available El objetivo del trabajo consiste en situar las controversias sobre el análisis económico de la gestión de los recursos naturales alrededor de dos cuestiones centrales: en primer lugar, el juicio de calificación sobre ¿Quién y bose que base califica los problemas ambientales y juzga la deseabilidad de las soluciones alternativas? y, en segundo lugar, ¿Cómo se define, en qué consiste, y que implicaciones prácticas tiene el concepto de escasez económica aplicado a los recursos naturales?. Después de definir el objeto de estudio de la economía de los recursos y de situarla en el contexto del análisis económico, se presentan las principales características del programa de investigación de la economía de los recursos renovables, no renovables y de la ecología de poblaciones y de ecosistemas. Todo esto configura el enfoque general de la economía ambiental que, en lo últimos apartados, se contrasta con la crítica de la misma planteada desde distintos enfoques alternativos.

  7. Detección y prevalencia de patógenos periodontales de una población con periodontitis crónica en Uruguay mediante metodología convencional y metagenómica

    Directory of Open Access Journals (Sweden)

    Virginia Papone

    Full Text Available Resumen Las enfermedades periodontales son un significativo problema mundial a nivel de salud humana. Décadas de investigaciones, evidencian que en la mayoría de los casos la periodontitis crónica es la más común, caracterizada por ser de evolución lenta, con formación de bolsas periodontales, posterior reabsorción del hueso alveolar, pérdida y destrucción de piezas dentarias y tejido óseo. Si bien se reconoce el origen multifactorial en el desarrollo de la periodontitis, es relevante la participación de la microbiota subgingival en la etiología de la enfermedad periodontal. Algunas de las especies bacterianas patógenas que han sido asociadas con el desarrollo de la enfermedad periodontal son Aggregatibacter actinomycetemcomitans, Porphyromonas gingivalis, Prevotella intermedia, Tannerella forsythia, Fusobacterium nucleatum, entre otras. En este estudio, nos propusimos investigar cuáles de éstas cinco especies estaban presentes en las bolsas periodontales de 51 pacientes uruguayos con periodontitis crónica. Para alcanzar éste objetivo se utilizó una técnica convencional microbiológica y metagenómica (multiplex-PCR. Los resultados de la técnica convencional microbiológica evidenciaron la presencia de A. actinomycetemcomitans (33% y de bacterias negras pigmentadas anaerobias (100% en las muestras. De los resultados obtenidos en la multiplex-PCR, se demostró que las especies de mayor prevalencia fueron F. nucleatum (100%, T. forsythia (92% y P. gingivalis (88%. Por el contrario, las especies de menor prevalencia fueron P. intermedia (39% y A. actinomycetemcomitans (33%

  8. Reducción del colesterol y aumento de la capacidad antioxidante por el consumo crónico de maíz morado (Zea mays L en ratas hipercolesterolémicas

    Directory of Open Access Journals (Sweden)

    Jorge Arroyo

    2007-04-01

    Full Text Available Objetivos: Determinar la actividad hipocolesterolémica y antioxidante del consumo crónico del extracto hidroalcohólico atomizado del maíz morado (Zea mays L en ratas hipercolesterolémicas. Materiales y métodos: Se utilizaron cinco grupos de seis ratas Holtzmann cada uno, uno sin hipercolesterolemia (control negativo, y cuatro con hipercolesterolemia inducida por consumo de colesterol puro vía oral durante 60 días: control positivo y tres para las dosis de 250, 500 y 1000 mg/kg, respectivamente. En el día 60 se determinaron los niveles séricos de colesterol total, triglicéridos y colesterol HDL (mg/dL, así como de malondialdehido (mmol/L para determinar la actividad antioxidante. Se comparó la diferencias de medias con ANOVA y test de Tukey. Resultados: Se observó una disminución del colesterol total en las ratas hipercolesterolémicas que consumieron dosis de 250 y 500 mg/kg en relación con el grupo control positivo (reducción de 21,5 y 11,2% respectivamente, p<0,01. No se observaron diferencias significativas sobre los niveles de triglicéridos y colesterol HDL. A mayor dosis se maíz morado se encontró una mayor reducción de radicales libres, con la dosis de 1000 mg/kg se redujo en 56,4% los niveles de malondialdehido (p< 0,01. Conclusiones: En condiciones experimentales, el consumo crónico del extracto hidroalcohólico atomizado de maíz morado disminuye los niveles de colesterol total y aumenta la capacidad antioxidante.

  9. A comparison of the neutron response of CR-39 made by different manufacturers

    International Nuclear Information System (INIS)

    Ipe, N.E.; Liu, J.C.; Buddemeier, B.R.; Miles, C.J.; Yoder, R.C.

    1991-09-01

    CR-39 was obtained from American Acrylics and Plastics, Inc. (A.A), N. E. Technology, Ltd. (N.E), and Tech/Ops Landauer, Inc. (LT). The dosemeters were exposed to radioisotopic neutron sources at SLAC, and moderated 252 Cf at ORNL. The A.A. and N.E. dosemeters were electrochemically etched (pre-etch in 6.5 N KOH at 60 degrees C for 1 hour and 45 minutes, a 5 hour etch at 3000 V and 60 Hz, a 23 minute blow-up step at 2 kHz and a post-etch for 15 minutes). Track densities were determined with the Homann Track Size Image Analyzer. The LT dosemeters were chemically etched in 5.5 N NaOH at 70 degrees C for 15.5 hours. Some A.A., N.E., and LT dosemeters were etched in 6.25 N NaOH at 70 degrees C for 6 hours. A pre-etch step in 60% methanol and 40% NaOH at 70 degrees C for 1 hour was added for some N.E. dosemeters. The results of these studies are reported in this paper. 3 refs., 2 figs., 2 tabs

  10. Optimization of microwave-induced chemical etching for rapid development of neutron-induced recoil tracks in CR-39 detectors

    International Nuclear Information System (INIS)

    Sahoo, G.S.; Tripathy, S.P.; Bandyopadhyay, T.

    2014-01-01

    A systematic investigation is carried out to optimize the recently established microwave-induced chemical etching (MICE) parameters for rapid development of neutron-induced recoil tracks in CR-39 detectors. Several combinations of all available microwave powers with different etching durations were analysed to determine the most suitable etching condition. The etching duration was found to reduce with increasing microwave power and the tracks were observed at about 18, 15, 12, and 6 min for 300, 450, 600 and 900 W of microwave powers respectively compared to a few hours in chemical etching (CE) method. However, for complete development of tracks the etching duration of 30, 40, 50 and 60 min were found to be suitable for the microwave powers of 900, 600, 450 and 300 W, respectively. Temperature profiles of the etchant for all the available microwave powers at different etching durations were generated to regulate the etching process in a controlled manner. The bulk etch rates at different microwave powers were determined by 2 methods, viz., gravimetric and removed thickness methods. A logarithmic expression was used to fit the variation of bulk etch rate with microwave power. Neutron detection efficiencies were obtained for all the cases and the results on track parameters obtained with MICE technique were compared with those obtained from another detector processed with chemical etching. - Highlights: • Microwave-induced chemical etching method is optimized for rapid development of recoil tracks due to neutrons in CR-39 detector. • Several combinations of microwave powers and etching durations are investigated to standardize the suitable etching condition. • Bulk-etch rates are determined for all microwave powers by two different methods, viz. gravimetric and removed thickness method. • The method is found to be simple, effective and much faster compared to conventional chemical etching

  11. A series of Zn/Cd coordination polymers constructed from 1,4-naphthalenedicarboxylate and N-donor ligands: Syntheses, structures and luminescence sensing of Cr{sup 3+} in aqueous solutions

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Dong-Cheng [College of Chemistry and Chemical Engineering, Northwest Normal University, Lanzhou 730070 (China); Key Laboratory for Preparation and Application of Ordered Structural Materials of Guangdong Province, Shantou University, Shantou 515063 (China); Fan, Yan; Si, Chang-Dai; Wu, Ya-Jun; Dong, Xiu-Yan; Yang, Yun-Xia; Yao, Xiao-Qiang [College of Chemistry and Chemical Engineering, Northwest Normal University, Lanzhou 730070 (China); Liu, Jia-Cheng, E-mail: jcliu8@nwnu.edu.cn [College of Chemistry and Chemical Engineering, Northwest Normal University, Lanzhou 730070 (China)

    2016-09-15

    A novel series of Zn/Cd coordination polymers based on H{sub 3}L, namely, [Zn{sub 2}(HL){sub 2}(bipy){sub 2}(H{sub 2}O){sub 6}]{sub n} (1), [Zn(HL)(phen)]{sub n} (2), [Cd{sub 3}L{sub 2}(bbi){sub 3}]{sub n} (3), [Zn{sub 3}L{sub 2}(bbi){sub 3}]{sub n} (4) [(H{sub 3}L =4-[(1-carboxynaphthalen-2-yl)oxy]phthalic acid, bipy =4,4′-bipyridine, phen =1,10-phenanthroline, bbi =1,1′-(1,4-butanediyl)bis(imidazole] have been successfully synthesized by solvothermal reaction. Compound 1 possesses two diverse 1D chains constructed by different bipy coligands, which were further connected to form a 3D supramolecular architecture by hydrogen bonding interactions. Compound 2 possesses a complicated 1D chain based on secondary building unit (SBU) with binuclear Zn cluster. Compounds 3 and 4 exhibit similar 2D→3D framework, which can be rationalized as (3,4,4)-connected 3D net with a Schläfli symbol of (6{sup 3}.8.10{sup 2}){sub 2}(6{sup 3}){sub 2}(6{sup 4}.8.10). In particular, compound 3 exhibited a high sensitivity for Cr{sup 3+} in aqueous solutions, which suggest that compound 3 is a promising luminescent probe for selectively sensing Cr{sup 3+}. - Graphical abstract: A series of novel Zn/Cd coordination polymers have been successfully synthesized by solvothermal reaction. The unique 3D Cd{sup 2+} polymer containing bbi as second ligand demonstrates high sensitivity for detection of toxic Cr{sup 3+} in aqueous solutions. Display Omitted - Highlights: • π-conjugated semirigid tricarboxylate ligands with naphthalene rings(H{sub 3}L) were rationally designed. • Four Zn/Cd coordination polymers based on H{sub 3}L have been successfully synthesized by solvothermal reaction. • Compound 3 is a promising luminescent probe for selectively sensing Cr{sup 3+} with high sensitivity in aqueous solutions.

  12. Vida académica de la facultad

    Directory of Open Access Journals (Sweden)

    Facultad de Medicina Revista

    1999-07-01

    Full Text Available Enciclopedia Académica sobre el Lenguaje en las Ciencias de la Salud / Convenio con la Universidad de Alcalá de Henares / Libro de Biología / XI Congreso de actualización en Rehabilitación Médica. Dolor crónico, diagnóstico y manejo integral / Primer Congreso Latinoamericano de Estudiantes de Nutrición y Dietética

  13. Determination of detection efficiency for radon and radon daughters with CR 39 track detector - a Monte Carlo study

    International Nuclear Information System (INIS)

    Nikezic, D.

    1994-01-01

    The detection effciency, ρ, (or a calibration coefficient k) for radon measurements with a solid state nuclear track detector CR 39 was determined by many authors. There is a considerable discrepancy among reported values for ρ. This situation was a challenge to develop a software program to calculation ρ. This software is based on Bethe-Bloch's expression for the stopping power for heavy charged particles in a medium, as wll as on the Monte Carlo Method. Track parameters were calculated by using an iterative procedure as given in G. Somogyi et al., Nucl. Instr. and Meth. 109 (1973) 211. Results for an open detector and for the detector in a diffusion chamber were presented in this article. (orig.)

  14. A method for in situ absolute DD yield calibration of neutron time-of-flight detectors on OMEGA using CR-39-based proton detectors

    Energy Technology Data Exchange (ETDEWEB)

    Waugh, C. J., E-mail: cjwaugh@mit.edu; Zylstra, A. B.; Frenje, J. A.; Séguin, F. H.; Petrasso, R. D. [Plasma Science and Fusion Center, MIT, Cambridge, Massachusetts 02139 (United States); Rosenberg, M. J.; Glebov, V. Yu.; Sangster, T. C.; Stoeckl, C. [Laboratory for Laser Energetics, Rochester, New York 14623 (United States)

    2015-05-15

    Neutron time of flight (nTOF) detectors are used routinely to measure the absolute DD neutron yield at OMEGA. To check the DD yield calibration of these detectors, originally calibrated using indium activation systems, which in turn were cross-calibrated to NOVA nTOF detectors in the early 1990s, a direct in situ calibration method using CR-39 range filter proton detectors has been successfully developed. By measuring DD neutron and proton yields from a series of exploding pusher implosions at OMEGA, a yield calibration coefficient of 1.09 ± 0.02 (relative to the previous coefficient) was determined for the 3m nTOF detector. In addition, comparison of these and other shots indicates that significant reduction in charged particle flux anisotropies is achieved when bang time occurs significantly (on the order of 500 ps) after the trailing edge of the laser pulse. This is an important observation as the main source of the yield calibration error is due to particle anisotropies caused by field effects. The results indicate that the CR-39-nTOF in situ calibration method can serve as a valuable technique for calibrating and reducing the uncertainty in the DD absolute yield calibration of nTOF detector systems on OMEGA, the National Ignition Facility, and laser megajoule.

  15. A method for in situ absolute DD yield calibration of neutron time-of-flight detectors on OMEGA using CR-39-based proton detectors.

    Science.gov (United States)

    Waugh, C J; Rosenberg, M J; Zylstra, A B; Frenje, J A; Séguin, F H; Petrasso, R D; Glebov, V Yu; Sangster, T C; Stoeckl, C

    2015-05-01

    Neutron time of flight (nTOF) detectors are used routinely to measure the absolute DD neutron yield at OMEGA. To check the DD yield calibration of these detectors, originally calibrated using indium activation systems, which in turn were cross-calibrated to NOVA nTOF detectors in the early 1990s, a direct in situ calibration method using CR-39 range filter proton detectors has been successfully developed. By measuring DD neutron and proton yields from a series of exploding pusher implosions at OMEGA, a yield calibration coefficient of 1.09 ± 0.02 (relative to the previous coefficient) was determined for the 3m nTOF detector. In addition, comparison of these and other shots indicates that significant reduction in charged particle flux anisotropies is achieved when bang time occurs significantly (on the order of 500 ps) after the trailing edge of the laser pulse. This is an important observation as the main source of the yield calibration error is due to particle anisotropies caused by field effects. The results indicate that the CR-39-nTOF in situ calibration method can serve as a valuable technique for calibrating and reducing the uncertainty in the DD absolute yield calibration of nTOF detector systems on OMEGA, the National Ignition Facility, and laser megajoule.

  16. A method for in situ absolute DD yield calibration of neutron time-of-flight detectors on OMEGA using CR-39-based proton detectors

    International Nuclear Information System (INIS)

    Waugh, C. J.; Zylstra, A. B.; Frenje, J. A.; Séguin, F. H.; Petrasso, R. D.; Rosenberg, M. J.; Glebov, V. Yu.; Sangster, T. C.; Stoeckl, C.

    2015-01-01

    Neutron time of flight (nTOF) detectors are used routinely to measure the absolute DD neutron yield at OMEGA. To check the DD yield calibration of these detectors, originally calibrated using indium activation systems, which in turn were cross-calibrated to NOVA nTOF detectors in the early 1990s, a direct in situ calibration method using CR-39 range filter proton detectors has been successfully developed. By measuring DD neutron and proton yields from a series of exploding pusher implosions at OMEGA, a yield calibration coefficient of 1.09 ± 0.02 (relative to the previous coefficient) was determined for the 3m nTOF detector. In addition, comparison of these and other shots indicates that significant reduction in charged particle flux anisotropies is achieved when bang time occurs significantly (on the order of 500 ps) after the trailing edge of the laser pulse. This is an important observation as the main source of the yield calibration error is due to particle anisotropies caused by field effects. The results indicate that the CR-39-nTOF in situ calibration method can serve as a valuable technique for calibrating and reducing the uncertainty in the DD absolute yield calibration of nTOF detector systems on OMEGA, the National Ignition Facility, and laser megajoule

  17. Track detection on the cells exposed to high Linear Energy Transfer heavy-ions by Cr-39 plastic and terminal deoxynucleotidyl transferase(Td T)

    International Nuclear Information System (INIS)

    Mehnati, P.; Keshtkar, A.; Mesbahi, A.; Sasaki, H.

    2006-01-01

    The fatal effect of ionizing radiation on cells depends on Linear Energy Transfer level. The distribution of ionizing radiation is sparse and homogeneous for low Linear Energy Transfer radiations such as X or y, but it is dense and concentrated for high Linear Energy Transfer radiation such as heavy-ions radiation. Materials and Methods: Chinese hamster ovary cells (CHO-K1) were exposed to 4 Gy Fe-ion 2000 keV/μm. The Cr-39 is a special and sensitive plastic used to verify exact position of heavy-ions traversal. Terminal deoxynucleotidyl transferase is an enzyme labeled with [3 H ] d ATP for detection of cellular DNA damage by autoradiography assay. Results: The track of heavy ions traversals presented by pit size was almost similar for all different doses of radiation. No pits to show the track of traversal were found in 20% of the cell nuclei of the irradiation. Apparently these fractions of cells wave not hit by heavy ions. Conclusion: This study indicated the possible usefulness of both the Cr-39 plastics and DNA labeling with Terminal deoxynucleotidyl transferase method for evaluating the biological effect of heavy-ions in comparison with low Linear Energy Transfer ionizing radiation

  18. Towards completely miscible PMMA nanocomposites reinforced by shear-stiff, nano-mica.

    Science.gov (United States)

    Ziadeh, Mazen; Weiss, Stephan; Fischer, Bianca; Förster, Stephan; Altstädt, Volker; Müller, Axel H E; Breu, Josef

    2014-07-01

    Optimizing the reinforcement of polymers with nanoplatelets requires optimization of the aspect ratio and the moduli of the filler while providing a complete stress transfer. Employing a novel shear-stiff, nano-mica with large aspect ratio, we focus on maximizing the interfacial interaction between filler and matrix. External surfaces of the nano-mica were selectively modified by a polycationic macro-initiator and two PMMA-polymer brushes of length below and above critical entanglement length, respectively, and the mechanical properties of the three PMMA nanocomposites were measured. The multiple electrostatic anchoring groups of the macro-initiator not only provide reliable adhesion but at the same time allow the variation of the degree of protonation providing a local match between the charge densities of the clay surface and the adsorbed macro-initiator. PMMA coating of the nano-mica via surface initiated polymerization yielded long-term stable suspensions in THF that showed birefringence of a nematic phase. Solution blending of the PMMA coated nano-mica allows for dispersing single clay tactoids in the translucent PMMA nanocomposites at 5 wt% clay loading as determined by transmission electron microscopy (TEM). Although significantly improved mechanical properties could be achieved as compared to nanocomposites made with conventional clay fillers, the full potential - as expressed by Halpin-Tsai equations - of the PMMA coated nano-mica can still not be completely utilized. This is attributed to the non-wetting character of the densely packed PMMA brushes attached to planar nanoplatelets. Copyright © 2014 Elsevier Inc. All rights reserved.

  19. Effect of surface treatment on the interfacial contact resistance and corrosion resistance of Fe–Ni–Cr alloy as a bipolar plate for polymer electrolyte membrane fuel cells

    International Nuclear Information System (INIS)

    Yang, Meijun; Zhang, Dongming

    2014-01-01

    The bipolar plate is an important component of the PEMFC (polymer electrolyte membrane fuel cell) because it supplies the pathway of electron flow between each unit cell. Fe–Ni–Cr alloy is considered as a good candidate material for bipolar plate, but it is limited to use as a bipolar plate due to its high ICR (interfacial contact resistance) and corrosion problem. In order to explore a cost-effective method on surface modification, various chemical and electrochemical treatments are performed on Fe–Ni–Cr alloy to acquire the effect of the surface modification on the ICR and corrosion behavior. The ICR and corrosion resistance of Fe–Ni–Cr alloy can be effectively controlled by the chemical treatment of immersion in the mixed acid solution with 10 vol% HNO 3 , 2 vol% HCl and 1 vol% HF for 10 min at 65 °C and then was placed in 30 vol% HNO 3 solution for 5 min. The chemical treatment is more effective on reducing ICR and improving corrosion resistance than that of electrochemical methods (be carried out in the 2 mol/L H 2 SO 4 solution with the electrical potential from −0.4 V to 0.6 V) for Fe–Ni–Cr alloy as a bipolar plate for polymer electrolyte membrane fuel cells. - Highlights: • The procedure of the surface treatments on Fe–Ni–Cr alloy as bipolar plate was described in detail. • Effects of various surface treatments on the interfacial contact resistivity and corrosion behavior were discussed. • The mechanism of the surface modification was particularly analyzed

  20. RACIONALIDADE ECONÔMICA, TRABALHO E ECOLOGIA EM ANDRÉ GORZ

    Directory of Open Access Journals (Sweden)

    André Langer

    Full Text Available O presente artigo tem por objetivo apresentar a análise crítica de André Gorz sobre o trabalho e a ecologia política a partir da centralidade que o conceito de racionalidade econômica no capitalismo adquire em seu pensamento. Para ele, a extensão ilimitada da racionalidade econômica ao trabalho e à natureza é considerada sem futuro do ponto de vista da sociedade. Gorz reconhece a íntima relação entre a crítica do capitalismo e a tarefa da ecologia política. Outro aspecto presente em sua obra, menos explorado, é a relação entre trabalho e crise ecológica. O capitalismo apropria-se do trabalho ou emprego não apenas para os seus interesses, mas também os transforma em instrumentos de destruição da natureza. Este paper objetiva também, fiel ao espírito do próprio Gorz, embora de maneira sucinta, indicar alguns horizontes alternativos.

  1. New possibility for high-resolution spectroscopy of nuclear particles entering CR-39 at selected dip angles

    Energy Technology Data Exchange (ETDEWEB)

    Somogyi, G.; Hunyadi, I.; Hafez, A.F. (Magyar Tudomanyos Akademia, Debrecen. Atommag Kutato Intezete); Espinosa, G. (Universidad Nacional Autonoma de Mexico, Mexico City. Inst. de Fisica)

    1984-01-01

    In nuclear reaction studies a differentiation of the reaction products according to their type and energy is generally required. At right angle of incidence a particle identification method based on the relation between the track diameter and particle energy can be well applied to plastic track detectors of low registration sensitivity. We have tried to extend this 'track-diameter method' to the high-sensitivity CR-39 sheets by selecting special incident angles for particle detection. The utility of such a measuring procedure, called 'track-size method', is presented for alpha and proton spectroscopy. A theory is developed to calculate at arbitrary angles the main parameters affecting the energy resolving power of the 'track-size method', namely the critical layer thickness (which has to be removed from the detector surface for track-induction) and the depth and minor axis of etch-pits.

  2. Discovery of an 'internal heating effect' during electrochemical etching of polymeric dosimeters: a study of polymer characteristics

    International Nuclear Information System (INIS)

    Sohrabi, M.

    1986-01-01

    This paper investigates the importance of the internal heating effect by studying the role of different polymer physical and chemical characteristics (composition, effective foil size, thickness and electrical properties), on the rate of heating or temperature rise responses for cellulose tri-acetate (CTA), cellulose acetate (CA), allyl diglycol carbonate (CR-39), cellulose nitrate (CN), cellulose acetate butyrate (CAB), polyester (PES), polycarbonate (PC) and polyethylene (PE). Efforts have been made to justify the observed effects by different mechanisms such as dielectric loss, electro-osmosis, dielectrophoresis, and electrostriction. (author)

  3. Crack propagation along polymer/non-polymer interfaces

    NARCIS (Netherlands)

    Vellinga, Willem-Pier; Fedorov, Alexander; De Hosson, Jeff T.

    2007-01-01

    Mechanisms of the propagation of crack fronts along interfaces between a glassy polymer and metal or glass are discussed. Specifically, the systems studied are Poly-Ethylene Terephthalate (PETG) spin-coated on A1, PETG-glass and PETG hot-pressed on Cr-sputtered glass. Cracks studied propagate in an

  4. Effect of synthetic mica on the thermal properties of poly(lactic acid

    Directory of Open Access Journals (Sweden)

    Diego Holanda Saboya Souza

    2014-01-01

    Full Text Available Poly(lactic acid/Somasif fluoromica nanocomposites were prepared by melt blending and their thermal properties investigated by DSC, TGA and DMA. Three different types of synthetic mica (Somasif ME-100, Somasif MAE and Somasif MPE were used at different contents (2.5, 5.0 and 7.5 wt %. The melt blending of PLA and these micas is characterized by a considerable reduction in the matrix molecular weight, which decreases when the nanofiller content is increased. For all nanocomposites, the thermal stability increases when mica is added to the polymer, with the Somasif MPE, producing the highest increase of the degradation temperature and highest reduction of Tg.

  5. Justicia epistémica y epistemologías del Sur

    Directory of Open Access Journals (Sweden)

    Miguel Mandujano Estrada

    2017-05-01

    Full Text Available Realizaré, en este trabajo, una síntesis de la dimensión epistemológica de la obra de Boaventura de Sousa Santos. A partir de la idea de justicia e injusticia epistémica, reconstruiré la dimensión metodológica de su plataforma crítica, a saber, la ecología de saberes. Intentaré establecer la relación de la injusticia epistémica con el colonialismo y defender la particularidad descolonial de las prácticas inscritas en las epistemologías del Sur y el cosmopolitismo subalterno.

  6. Dinámica ambiental y económica en la localidad de Puente Aranda en Bogotá

    Directory of Open Access Journals (Sweden)

    Carlos Fernando Parra Moreno

    2014-01-01

    Full Text Available Este documento muestra los resultados parciales de la investigación “Responsabilidad social y ambiental de la industria manufacturera en la localidad de Puente Aranda en la ciudad de Bogotá como alternativa al desarrollo humano integral sustentable”, realizados dentro del marco de trabajo del grupo de investigación Girsa. El estudio se basó en el análisis de la dinámica poblacional, ambiental y económica de la dicha localidad, a través de la metodología de la matriz de Vester. Con este instrumento se logró identificar las relaciones e interacciones dinámicas de todos los actores locales en el tiempo y en el espacio. Dentro de los problemas críticos que se encontraron en la localidad de Puente Aranda se encontró el agotamiento de fuentes hídricas, poca conciencia y educación ambiental de la población, una mala disposición de basuras, la no disponibilidad de servicios públicos para los nuevos asentamientos y altos niveles de emisión de partículas contaminantes.

  7. Fission studies of gold induced by (1665 MeV) π- using a CR-39 detector

    International Nuclear Information System (INIS)

    Muhammad Ikram Shahzad; Yasin, Zafar; Sher, Gul

    2012-01-01

    The fission cross section and fission probability of 197 Au, induced by (1665 MeV) π'-, have been studied using CR-39 track detectors. A 4π-geometry was used to count track statistics. A beam of negative pions of 1665 MeV was produced at AGS of Brookhaven National Laboratory, USA, and allowed to fall normally on the stack. Two detectors from the stack were scanned for fission fragment tracks after etching in 6N NaOH at 70 ℃. The statistics of fission fragment tracks in both detectors were obtained. It was found that there was a marked asymmetry of registered tracks with respect to the forward and backward hemispheres. This asymmetry could be partly accounted for on the basis of momentum transfer to the struck nucleus. On the basis of counting statistics fission cross section was measured, and fission probability was determined by dividing the fission cross section with the reaction cross section. The fission cross-section and fission probability were compared with the computed values using the cascade-exciton model code CEM95. (authors)

  8. Determination of the exhalation rate of radon and thoron from building materials by detectors Cr-39

    International Nuclear Information System (INIS)

    Vasidov, A.

    2005-01-01

    Full text: The building materials (BM) such as granite, bricks, sand, cement etc., contain uranium and thorium in various amounts. Therefore the knowledge of true value exhalation rate of Rn and Tn from BM represents scientific and practical interest in environmental radiation protection. In present work, we have used calibrated plastic cups with two detectors Cr-39. The detected surface of the cup is situated in perpendicular position surface BM and were exposed for 20-30 days. The first detector fixed the bottom on distance from surface of BM and records alpha particles from Rn-222 only. The second detector records alpha particles of the thoron and radon. After exposition, the detectors chemically etched and analyzed. The values of the exhalation rate per unit area of the granite, concrete, fired and unfired bricks, sand, cement, alabaster varied 0.091 - 0.1 Bq m -2 h -1 for the radon, 200 - 5800 Bq m -2 h - 1 for the thoron, accordingly

  9. Interrelated temperature dependence of bulk etch rate and track length saturation time in CR-39 detector

    International Nuclear Information System (INIS)

    Azooz, A.A.; Al-Jubbori, M.A.

    2013-01-01

    Highlights: • New empirical parameterization of CR-39 bulk etch rate. • Bulk etch rates measurements using two different methods give consistent results. • Temperature independence of track saturation length. • Two empirical relation between bulk etch rate and temperature are suggested. • Simple inverse relation between bulk etch rate and track saturation time. -- Abstract: Experimental measurements of the etching solution temperature dependence of bulk etch rate using two independent methods revealed a few interesting properties. It is found that while the track saturation length is independent of etching temperature, the etching time needed to reach saturation is strongly temperature-dependent. It is demonstrated that there is systematic simple inverse relation between track saturation time, and etching solution temperature. In addition, and although, the relation between the bulk etch rate and etching solution temperature can be reasonably described by a modified form of the Arrhenius equation, better fits can be obtained by another equation suggested in this work

  10. Otra ciencia económica

    Directory of Open Access Journals (Sweden)

    Daniel Innerarity

    2012-04-01

    Full Text Available El autor hace una crítica a la pretensión de la ciencia económica de constituirse como un saber exacto e hiperespecializado al considerar que esta pretensión se ha traducido en una pérdida de la capacidad que es necesaria para comprender la complejidad social de las realidades económicas. Seducida por el objetivo de la exactitud, la economía parece haber olvidado su carácter de construcción social. Además, la economía ha olvidado que es una más entre las ciencias sociales y el largo periodo en el que se ha separado de ellas reivindicando su plena autonomía no ha sido satisfactorio ni para ella ni para el resto de las ciencias sociales. Según el autor la crítica al capitalismo contemporáneo, si quiere ser más radical que moralizante, debe dirigirse a combatir el supuesto realismo de la ciencia económica dominante.The author criticizes the pretension of economic sciences of being an exact science and its tendency to specialization. The consequences of those pretensions are a loss of its capacity to understand the social complexity of the economic realities. The economy, seduced by its aim of exactitude, seems to forget that it is a social construction. Moreover, economy seems to forget that it is just a social science, and for a long period of time economy evolved as a separated and autonomous science; that time was not good neither for economic science neither for social sciences in general. According to the author, if we want to build a more radical and not only moralizing critique to contemporary capitalism, we must criticize the hypothetical realism of the economic science. 

  11. In-situ irradiation studies on the effects of helium on the microstructural evolution of V-3.8Cr-3.9Ti

    International Nuclear Information System (INIS)

    Doraiswamy, N.; Kestel, B.; Alexander, D.E.

    1996-11-01

    Role of He in microstructural evolution of V-3.8Cr-3.9Ti was investigated by in-situ TEM of as-prepared and He implanted (<10 appM) samples subjected to 200 keV He irradiation at RT. Quantitative analysis showed an increase in defect density and size with irradiation in both. The unimplanted sample showed a defect density consistent with electron irradiation experiments. The He preimplanted sample had slightly larger defects and a substantially greater increase in number density of defects. This is consistent with a mechanism of He trapping by formation of He-vacancy-X (X=C,N,O) complexes

  12. Payroll loans and its relationship with the aggregate economic activity (2004-2014 / Crédito consignado e sua relação com a atividade econômica agregada (2004-2014

    Directory of Open Access Journals (Sweden)

    Aline Beatriz Schuh

    2017-02-01

    Full Text Available Purpose: Identify the relationship between the granting of payroll loans and macroeconomic aggregates, from 2004 to 2014, through an analysis of the influence of this type of credit on the aggregate economic activity in Brazil. Originality/gap/relevance/implications: Payroll loans are very representative in the Brazilian credit market, and the discussion on this topic is very extensive, because it is directly linked to the economic growth of a country. However, there is a gap in the literature on this subject, since most studies stress behavioral finances, or the legal aspects of contracts, and also because this type of credit is recent in the Brazilian economy. Key methodological aspects: This is quantitative approach performed through the estimation of the Vector Error Correction Model (VECM, which enabled the computation of impulse-response functions, the variance decomposition and the Granger causality test. Summary of key results: The results indicate that the granting of payroll loans causes an increase on macroeconomic aggregates in the short term, but over longer periods of time this increase tends to be eliminated. Key considerations/conclusions: The granting of payroll loans influences the behavior of the economic activity. However, despite the fact that its concession provides leverage in the short term, this growth is not sustainable in the long-term. In this scenario, there is exponential growth in household consumption over the past decade; however, the industry productivity and the investments did not follow this evolution. It is inferred from this that the current growth model generates expansion, but its effects are limited. Objetivo: Identificar a relação entre a concessão de crédito consignado e os agregados macroeconômicos reais, no período de 2004 a 2014, a partir de uma análise da influência que essa modalidade de crédito exerce na atividade econômica agregada. Originalidade/lacuna/relevância/implicações: O cr

  13. Lithium Insertion in LiCr3O8, NaCr3O8, and KCr3O8 at Room Temperature and at 125°C

    DEFF Research Database (Denmark)

    Koksbang, R.; Fauteux, D.; Norby, P.

    1989-01-01

    Lithium insertion and deinsertion reactions have been carried out with LiCr3O8, NaCr3O8, and KCr3O8 chemically andelectrochemically at room temperature and at 125°C. The electrochemical experiments were performed with a nonaqueousliquid electrolyte at room temperature and with a polymer electroly...... is close to 4Li/NaCr3O8 and 1.3Li/KCr3O8.Lithium ion diffusion coefficients are similar for the two compounds in the comparable composition range.Thermally, the fully lithiated compounds appear to be as stable as the pristine materials.......Lithium insertion and deinsertion reactions have been carried out with LiCr3O8, NaCr3O8, and KCr3O8 chemically andelectrochemically at room temperature and at 125°C. The electrochemical experiments were performed with a nonaqueousliquid electrolyte at room temperature and with a polymer electrolyte....... At elevated temperatures, the isostructural compounds NaCr3O8 and KCr3O8 are able to accommodate morethan 4Li/MCr3O8. During this process, minor structural changes are observed. At room temperature, NaCr3O8 and KCr3O8also accommodate Li topotactically, but the maximum number of Li inserted per formula...

  14. Dinámica económica e institucionalización de la tributación directa. Trasnformaciones institucionales el caso de administración de impuestos 1920-1935

    OpenAIRE

    Oscar Rodríguez Salazar

    1999-01-01

    Las tres primeras décadas del presente siglo son el escenario de profundas transformaciones en la estructura económica del país y en el modelo institucional. El desarrollo de la economía cafetera, el acceso a la economía de crédito internacional, los cambios en la política económica, la ampliación de la infraestructura, el acelerado proceso de urbanización, los cambios demográficos, la proletarización de un contingente considerable de masas campesinas y el inicio del proceso de industrializac...

  15. Análise de crédito por meio de modelos de previsão de insolvência: um estudo de caso na Empresa Cerâmica Alfa S.A. = Credit analysis through models for the forcasting of insolvency of the company Cerâmica Alfa S.A.

    Directory of Open Access Journals (Sweden)

    Paula Bez Birolo

    2011-07-01

    Full Text Available O objetivo deste artigo é avaliar os benefícios da utilização de modelos de previsão de insolvência para a análise de crédito em uma empresa do setor cerâmico. É descritivo, de caráter quantitativo, realizado por meio de um estudo de caso na empresa Cerâmica ALFA S.A. Para execução da pesquisa selecionou-se intencionalmente seis clientes, de acordo com os seguintes dados: a informações creditícias disponíveis no sistema gerencial de crédito/cobrança e b demonstrações contábeis divulgadas nos sites dos respectivos clientes. Os resultados apontam que os modelos de Elizabetsky e Kanitz demonstram fragilidades em identificar a situação financeira dos clientes. O modelo de previsão de insolvência desenvolvido por Matias apresenta melhor desempenho, em relação aos anteriores, para a análise de crédito. Conclui-se que é vantajoso utilizar o modelo de Matias para a análise de crédito, pois ele é adequado às necessidades da empresa e serve como um instrumento para auxílio na concessão de crédito e tomada de decisão. The objective of this article is to assess the benefits of using insolvency forecasting models for the credit analysis of a company in the ceramic sector. This study is descriptive of a quantitative nature through a case study in Cerâmica ALFA S.A. Six clients with the following data were intentionally selected for the execution of the research: a credit information available in the credit/collection management system and b account statements divulged in the sites of the respective clients. The results show that the Elizabetsky and Kanitz models demonstrated fragility in identifying the financial situation of the clients. The insolvency forecasting model developed by Matias showed better performance in relation to the previous ones for credit analysis. It was concludrd that it is advantageous to use the Matias model for credit analysis, because it is suitable for the company’s requirements and serves

  16. Kinetics of Ar isotopes during neutron irradiation: 39Ar loss from minerals as a source of error in 40Ar/39Ar dating

    International Nuclear Information System (INIS)

    Hess, J.C.; Lippolt, H.J.

    1986-01-01

    The loss of 39 Ar from minerals in the course of neutron activation for 40 Ar/ 39 Ar dating is studied by directly measuring the loss rates in vacuum-sealed ampoules. Biotite shows 39 Ar losses between 0.1% and 16%. These losses are predominantly due to diffusion processes from K-poor alteration-phase intergrowths in the biotites at the elevated temperatures during the irradiation. Estimates for the irradiation temperatures range from 150 0 to 180 0 C. Direct 39 Ar recoil loss from biotite seems to be minor compared to difussion loss of recoil-implanted 39 Ar. Precise 40 Ar/ 39 Ar dating of biotites therefore requires the measurement of the 39 Ar losses during irradiation. Glauconite loses not only neutron-induced Ar isotopes ( 39 Ar: 20-22%, 37 Ar: 17-19%) but also radiogenic 40 Ar(∼9%). Slight 39 Ar losses are also observed for light micas (0.2% and 0.35%), hornblendes (0.1%) and sanidines (200 and 700 ppm). 25 refs.; 4 figs.; 6 tabs

  17. Study on the influence of CR-39 detector size on radon progeny detection in indoor environments

    Energy Technology Data Exchange (ETDEWEB)

    Pereira, L. A.; Hadler, J. C.; Lixandrão F, A. L.; Guedes, S.; Takizawa, R. H. [Instituto de Física Gleb Wataghin, Universidade Estadual de Campinas, UNICAMP, 13083-970 Campinas, SP (Brazil)

    2014-11-11

    It is well known that radon daughters up to {sup 214}Po are the real contaminants to be considered in case of indoor radon contamination. Assemblies consisting of 6 circular bare sheets of CR-39, a nuclear track detector, with radius varying from 0.15 to 1.2 cm were exposed far from any material surface for periods of approximately 6 months in 13 different indoor rooms (7 workplaces and 6 dwellings), where ventilation was moderate or poor. It was observed that track density was as greater as smaller was the detector radius. Track density data were fitted using an equation deduced based on the assumption that the behavior of radon and its progeny in the air was described by Fick's Law, i.e., when the main mechanism of transport of radon progeny in the air is diffusion. As many people spend great part of their time in closed or poorly ventilated environments, the confirmation they present equilibrium between radon and its progeny is an interesting start for dosimetric calculations concerning this contamination.

  18. El determinismo geográfico, la geografía económica y el imperialismo en la obra de Estrabón

    OpenAIRE

    Montero Barrientos, Daniel

    2010-01-01

    RESUMEN: El presente artículo trata de revisar algunas de las ideas clave del pensamiento de Estrabón y su finalidad dentro de la Geografía: el determinismo geográfico, la geografía económica y el imperialismo. Una nueva lectura crítica del texto permite llegar a conclusiones sustancialmente distintas a las de buena parte de la historiografía actual. Así el determinismo geográfico posidoniano no influye teóricamente en Estrabón, quien por el contrario lo crítica; la geografía económica, por s...

  19. Major histocompatibility complex class I-related chain A/B (MICA/B) expression in tumor tissue and serum of pancreatic cancer: Role of uric acid accumulation in gemcitabine-induced MICA/B expression

    International Nuclear Information System (INIS)

    Xu, Xiulong; Rao, Geetha S; Groh, Veronika; Spies, Thomas; Gattuso, Paolo; Kaufman, Howard L; Plate, Janet; Prinz, Richard A

    2011-01-01

    Major histocompatibility complex class I-related chain A and B (MICA/B) are two stress-inducible ligands that bind the immunoreceptor NKG2D and play an important role in mediating the cyotoxicity of NK and T cells. In this study, we sought to study MICA/B expression in pancreatic cancer and to determine whether and how genotoxic drugs such as gemcitabine can affect MICA/B expression and natural killer cytotoxity. Seven pancreatic cancer cell lines were analyzed for MICA/B expression by flow cytometry and for their sensitivity to NK-92 cell killing by a 51 Cr release assay. MICA/B expression in tumor tissues and sera of pancreatic cancer was analyzed by immunohistochemical staining (IHC) and ELISA, respectively. Two MICA/B-positive cell lines were sensitive to the cytotoxic activity of NK-92 cells. Other two MICA/B-positive cell lines and three MICA/B-negative cell lines were resistant to NK-92 cell killing. MICA/B expression was positive in 17 of 25 (68%) pancreatic ductal adenocarcinomas but not in normal pancreatic ductal epithelial cells. Serum MICA/B levels were significantly elevated in patients with pancreatic adenocarcinomas but did not correlate with the stage of pancreatic cancer and patient survival. Gemcitabine therapy led to increased serum MICA levels in 6 of 10 patients with detectable serum MICA. Allopurinol, an inhibitor of xanthine oxidoreductase that converts xanthine to uric acid, blocked uric acid production, MICA/B expression, and sensitivity to NK-92 cell killing toward a PANC-1 cancer cell line exposed to radiation and two genotoxic drugs, gemcitabine and 5-fluorouracil. The levels of MICA/B expression in serum and tissue of pancreatic cancer are elevated. DNA damage-induced MICA/B expression is mediated through increased uric acid production

  20. Major histocompatibility complex class I-related chain A/B (MICA/B expression in tumor tissue and serum of pancreatic cancer: Role of uric acid accumulation in gemcitabine-induced MICA/B expression

    Directory of Open Access Journals (Sweden)

    Kaufman Howard L

    2011-05-01

    Full Text Available Abstract Background Major histocompatibility complex class I-related chain A and B (MICA/B are two stress-inducible ligands that bind the immunoreceptor NKG2D and play an important role in mediating the cyotoxicity of NK and T cells. In this study, we sought to study MICA/B expression in pancreatic cancer and to determine whether and how genotoxic drugs such as gemcitabine can affect MICA/B expression and natural killer cytotoxity. Methods Seven pancreatic cancer cell lines were analyzed for MICA/B expression by flow cytometry and for their sensitivity to NK-92 cell killing by a 51Cr release assay. MICA/B expression in tumor tissues and sera of pancreatic cancer was analyzed by immunohistochemical staining (IHC and ELISA, respectively. Results Two MICA/B-positive cell lines were sensitive to the cytotoxic activity of NK-92 cells. Other two MICA/B-positive cell lines and three MICA/B-negative cell lines were resistant to NK-92 cell killing. MICA/B expression was positive in 17 of 25 (68% pancreatic ductal adenocarcinomas but not in normal pancreatic ductal epithelial cells. Serum MICA/B levels were significantly elevated in patients with pancreatic adenocarcinomas but did not correlate with the stage of pancreatic cancer and patient survival. Gemcitabine therapy led to increased serum MICA levels in 6 of 10 patients with detectable serum MICA. Allopurinol, an inhibitor of xanthine oxidoreductase that converts xanthine to uric acid, blocked uric acid production, MICA/B expression, and sensitivity to NK-92 cell killing toward a PANC-1 cancer cell line exposed to radiation and two genotoxic drugs, gemcitabine and 5-fluorouracil. Conclusions The levels of MICA/B expression in serum and tissue of pancreatic cancer are elevated. DNA damage-induced MICA/B expression is mediated through increased uric acid production.

  1. Recubrimientos por PVD decorativos sobre cerámicas

    Directory of Open Access Journals (Sweden)

    García, J. A.

    2006-08-01

    Full Text Available During the last years PVD coatings has been used for decorative purposes on ceramics and other substrates. Standards layers like TiN, CrN, TiCN, etc, give us the possibly of obtaining a wide range of colours, with a good mechanical, chemical properties. This paper gathers the works carried out in the Center of Advance Surface engineering of AIN during the three last years in the field of the decorative coatings. Different layer have been deposited by means of a METAPLAS 232 PVD equipment. A complete chemical and mechanical characterisation have been carried out on the different deposited layers like ultramicroindentation, scratch tests, wear resistance and GDOES.

    En los últimos años se ha venido estudiado la aplicabilidad de las técnicas de depósitos mediante métodos físicos en fase vapor (PVD, para la realización de recubrimientos sobre cerámicas y otros substratos con fines decorativos. Los recubrimientos estándar por PVD como el TiN, CrN, TiCN, etc, ofrecen la posibilidad de conseguir acabados de apariencia metálica, de una amplia gama de colores, y con buenas propiedades mecánicas y químicas, como resistencia a la abrasión, estabilidad térmica, o resistencia a la corrosión. En este trabajo se recogen las experiencias realizadas en el recubrimiento y caracterización de cerámicas decorativas, durante los tres últimos años, en el Centro de Ingeniería de Superficies de la Asociación de la Industria Navarra. Los distintos tipos de recubrimientos se han realizado mediante un equipo de PVD modelo METAPLAS 232, con seis evaporadores de arco eléctrico y sistema de limpieza iónica patentado AEGD. Los recubrimientos han sido caracterizados, tanto química como mecánicamente, empleando las más modernas técnicas tribológicas (ultramicrodureza, scrascth tests, resistencia al desgaste... y espectroscópicas óptica por descarga luminiscente (GDOES. Los resultados obtenidos muestran que las técnicas de PVD son una

  2. Study of gamma irradiation effects on the etching and optical properties of CR-39 solid state nuclear track detector and its application to uranium assay in soil samples

    International Nuclear Information System (INIS)

    Amol Mhatre; Kalsi, P.C.

    2011-01-01

    The gamma irradiation effects in the dose range of 2.5-43.0 Mrad on the etching and optical characteristics of CR-39 solid state nuclear track detector (SSNTD) have been studied by using etching and UV-Visible spectroscopic techniques. From the measured bulk etch rates at different temperatures, the activation energies for bulk etching at different doses have also been determined. It is seen that the bulk etch rates increase and the activation energies for bulk etching decrease with the increase in gamma dose. The optical band gaps of the unirradiated and the gamma -irradiated detectors determined from the UV-Visible spectra were found to decrease with the increase in gamma dose. These results have been explained on the basis of scission of the detector due to gamma irradiation. The present studies can be used for the estimation of gamma dose in the range of 2.5-43.0 Mrad and can also be used for estimating track registration efficiency in the presence of gamma dose. The CR-39 detector has also been applied for the assay of uranium in some soil samples of Jammu city. (author)

  3. Hidroxyapatite Coating on CoCrMo Alloy Titanium Nitride Coated Using Biomimetic Method

    International Nuclear Information System (INIS)

    Charlena; Sukaryo, S.G.; Fajar, M.

    2016-01-01

    Bone implants is a way to cure broken bones which is being developed. The implants can be made of metals, ceramics and polymers. Metallic materials commonly used are titanium (Ti), stainless steel, and metal alloys. This study used Co-based alloys, i.e. CoCrMo coated with titanium nitride (TiN) which was then coated on hidroxyapatite (HAp). The HAp coating on the surface of CoCrMo alloy was done by biomimetic methods, first by soaking the metal alloys in simulated body fluid (SBF) solution for 18, 24, and 36 hours. The immersion in the SBF solution produced white coat on the surface of the metal alloy. The layers formed were analyzed by scanning electron microscope (SEM) and characterized by x-ray diffractometer (XRD). Based on the SEM results of 36 hours treatment, the morphology of apatite crystal formed fine grains. According to XRD result, there were HAp peaks at angles 2θ 31.86, 32.25, dan 39.48. However, there were also CaCO 3 peaks at angles 2θ 29.46, 36.04, and 46.79. It indicated the pure HAp is not yet formed. (paper)

  4. Hidroxyapatite Coating on CoCrMo Alloy Titanium Nitride Coated Using Biomimetic Method

    Science.gov (United States)

    Charlena; Sukaryo, S. G.; Fajar, M.

    2016-11-01

    Bone implants is a way to cure broken bones which is being developed. The implants can be made of metals, ceramics and polymers. Metallic materials commonly used are titanium (Ti), stainless steel, and metal alloys. This study used Co-based alloys, i.e. CoCrMo coated with titanium nitride (TiN) which was then coated on hidroxyapatite (HAp). The HAp coating on the surface of CoCrMo alloy was done by biomimetic methods, first by soaking the metal alloys in simulated body fluid (SBF) solution for 18, 24, and 36 hours. The immersion in the SBF solution produced white coat on the surface of the metal alloy. The layers formed were analyzed by scanning electron microscope (SEM) and characterized by x-ray diffractometer (XRD). Based on the SEM results of 36 hours treatment, the morphology of apatite crystal formed fine grains. According to XRD result, there were HAp peaks at angles 2θ 31.86, 32.25, dan 39.48. However, there were also CaCO3 peaks at angles 2θ 29.46, 36.04, and 46.79. It indicated the pure HAp is not yet formed.

  5. CR-39 track detector calibration for H, He, and C ions from 0.1-0.5 MeV up to 5 MeV for laser-induced nuclear fusion product identification.

    Science.gov (United States)

    Baccou, C; Yahia, V; Depierreux, S; Neuville, C; Goyon, C; Consoli, F; De Angelis, R; Ducret, J E; Boutoux, G; Rafelski, J; Labaune, C

    2015-08-01

    Laser-accelerated ion beams can be used in many applications and, especially, to initiate nuclear reactions out of thermal equilibrium. We have experimentally studied aneutronic fusion reactions induced by protons accelerated by the Target Normal Sheath Acceleration mechanism, colliding with a boron target. Such experiments require a rigorous method to identify the reaction products (alpha particles) collected in detectors among a few other ion species such as protons or carbon ions, for example. CR-39 track detectors are widely used because they are mostly sensitive to ions and their efficiency is near 100%. We present a complete calibration of CR-39 track detector for protons, alpha particles, and carbon ions. We give measurements of their track diameters for energy ranging from hundreds of keV to a few MeV and for etching times between 1 and 8 h. We used these results to identify alpha particles in our experiments on proton-boron fusion reactions initiated by laser-accelerated protons. We show that their number clearly increases when the boron fuel is preformed in a plasma state.

  6. Uranium concentration in blood samples of Southern Iraqi leukemia patients using CR-39 track detector

    International Nuclear Information System (INIS)

    Al-Hamzawi, A.A.; Al-Qadisiyah University, Qadisiyah; Jaafar, M.S.; Tawfiq, N.F.

    2014-01-01

    The simple and effective technique of fission track etch has been applied to determine trace concentration of uranium in human blood samples taken from two groups of male and female participants: leukemia patients and healthy subjects group. The blood samples of leukemia patients and healthy subjects were collected from three key southern governorates namely, Basrah, Muthanna and Dhi-Qar. These governorates were the centers of intensive military activities during the 1991 and 2003 Gulf wars, and the discarded weapons are still lying around in these regions. CR-39 track detector was used for registration of induced fission tracks. The results show that the highest recorded uranium concentration in the blood samples of leukemia patients was 4.71 ppb (female, 45 years old, from Basrah) and the minimum concentration was 1.91 ppb (male, 3 years old, from Muthanna). For healthy group, the maximum uranium concentration was 2.15 ppb (female, 55 years old, from Basrah) and the minimum concentration was 0.86 ppb (male, 5 years old, from Dhi-Qar). It has been found that the uranium concentrations in human blood samples of leukemia patients are higher than those of the healthy group. These uranium concentrations in the leukemia patients group were significantly different (P < 0.001) from those in the healthy group. (author)

  7. Study of /sup 210/Pb and /sup 210/Po distributions in environmental samples by CR-39 track detector

    Energy Technology Data Exchange (ETDEWEB)

    Hunyadi, I.; Somogyi, G.; Szilagyi, S. (Magyar Tudomanyos Akademia, Debrecen. Atommag Kutato Intezete)

    1984-01-01

    Activity concentration distributions of long-lived alpha-emitters in aerosol samples are analysed by high-resolution autoradiography in CR-39. A study of the alpha-activity attached to aerosols of different particulate sizes separated by a cascade impactor is also performed. It is found that, in the majority of samples, the alpha-activity can be dominantly related to the presence of /sup 210/Po produced by its beta-active precursor /sup 210/Pb. In our studies we have applied the following methods: 1) analysis of alpha-decay properties by means of autoradiographs taken at different post-sampling times, 2) spectroscopical study of individual alpha-tracks and track clusters by a method developed by us for high-resolution alpha-energy determination. In the second method the parameters to be measured are the major axis of surface track opening, the diameter of etched out track end, the total length measurable on the surface along the projected track, and the thickness of layer etched away from the detector surface.

  8. Evaluation of the shear bond strength of the union between two CoCr-alloys and a dental ceramic Avaliação da resistência ao cisalhamento da união entre duas ligas a base de CoCr e uma cerâmica

    Directory of Open Access Journals (Sweden)

    Mariana Pretti

    2004-12-01

    Full Text Available INTRODUCTION: Based on the importance of the integrity of the metal/ceramic interface, the purpose of this work was to evaluate the shear bond strength of the metal-ceramic union of two Co-Cr alloys (Wirobond C, Bego; Remanium 2000, Dentaurum combined with Omega 900 ceramic (Vita Zahnfabrik. MATERIAL AND METHOD: Eleven cylindrical matrixes were made for each alloy, and the metallic portion was obtained with the lost wax casting technique with standardized waxing of 4mm of height and of 4mm of diameter. The ceramic was applied according to the manufacturer's recommendations with the aid of a teflon matrix that allowed its dimension to be standardized in the same size as the metallic portion. The specimens were submitted to the shear bond test in an universal testing machine (EMIC, with the aid of a device developed for such intention, and constant speed of 0.5mm/min. RESULTS AND CONCLUSIONS: The mean resistance was 48.387MPa for Wirobond C alloy, with standard deviation of 17.718, and 55.956MPa for Remanium 2000, with standard deviation of 17.198. No statistically significant difference was observed between the shear strength of the two metal-ceramic alloys.INTRODUÇÃO: Baseados na importância da integridade da interface metal-cerâmica, este trabalho tem como objetivo avaliar a resistência ao cisalhamento da união metal-cerâmica de duas ligas de Co-Cr (Wirobond C, Bego; Remanium 2000, Dentaurum combinadas com a cerâmica Omega 900 (Vita Zahnfabrik. MATERIAIS E MÉTODOS: Foram confeccionados 11 corpos-de-prova cilíndricos para cada liga utilizada, sendo que a porção metálica foi obtida por fundição pela técnica da cera perdida, através de enceramentos padronizados com 4mm de altura por 4mm de diâmetro. A aplicação da cerâmica foi realizada segundo recomendações do fabricante, com auxílio de uma matriz de teflon que permitia sua padronização com as mesmas dimensões da porção metálica. Os corpos-de-prova foram submetidos

  9. Uranium concentration measurements in human blood for some governorates in Iraq using CR-39 track detector

    International Nuclear Information System (INIS)

    Tawfiq, N.F.; Ali, L.T.; Al-Jobouri, H.A.

    2013-01-01

    The sensitive and simple technique of fission track etch has been applied to determine trace concentration of uranium in blood samples for occupational and non-occupational workers, male and female, using CR-39 track detector that is employed for registration of induced fission tracks. The results show that the highest recorded uranium concentration in human blood of workers in the ministry of Science and Technology were 1.90 ppb (male, 36 years old, 12 years' work experience, and living in Basrah governorate) and minimum concentration 0.26 ppb (female, 40 years old, 10 years' work experience, and living in Baghdad), while for non-occupational worker, the maximum uranium concentration was 1.76 ppb (female, 63 years old, and living in Al-Muthana) and minimum concentration was 0.28 ppb (female, 20 years old, and living in Baghdad). It has also been found that the uranium concentration in human blood samples of workers in the ministry of Science and Technology are higher than those of non-occupational workers, and the uranium concentrations for female workers and for non-occupational workers were higher than those for male workers and non-occupational workers. (author)

  10. Dinâmica afectiva e performance intelectual em crianças e adolescentes submetidos a transplante hepático e com insuficiência hepática crónica: estudo exploratório

    OpenAIRE

    Assunção, Carina Pina

    2015-01-01

    Dissertação de mestrado em Psicologia Clínica e da Saúde (Psicopatologia e Psicoterapias Dinâmicas), apresentada à Faculdade de Psicologia e de Ciências da Educação da Universidade de Coimbra A vivência de um processo insuficiência hepática crónica, no caso pediátrico (crianças e adolescentes), especialmente, quando culmina na irrevogabilidade de transplante, faz-se acompanhar de uma multiplicidade de repercussões psicossociais, como sendo a expressão de sintomatologia psico(pato)lógica, e...

  11. Prognostic value of MICA/B in cancers: a systematic review and meta-analysis.

    Science.gov (United States)

    Zhao, Yijing; Chen, Naifei; Yu, Yu; Zhou, Lili; Niu, Chao; Liu, Yudi; Tian, Huimin; Lv, Zheng; Han, Fujun; Cui, Jiuwei

    2017-11-10

    MHC class I chain related-proteins A (MICA) and B (MICB) are natural killer group 2D ligands that mediate tumor surveillance. Several studies have suggested that MICA/B levels predict clinical outcomes in patients with cancer; however, this remains contentious. Here, we present a systematic review and meta-analysis of available studies of the prognostic value of MICA/B in cancer. We searched PubMed, Embase, Clinicaltrials.gov, and Cochrane Library to identify studies published from inception to July 2017 that assessed MICA/B in patients with cancer. The hazard ratio (HR) and 95% confidence interval (CI) of MICA/B were extracted for overall survival (OS) analysis. A total of 19 studies comprising 2,588 patients with 10 different types of cancer were included in the study. Low sMICA/B levels were found associated with significantly longer OS (HR = 1.65, 95% CI [1.42-1.92], P < 0.00001). Patients with cancers of digestive system that exhibited high MICA/B expression had significantly longer OS in (HR = 0.56, 95% CI [0.39-0.80], P = 0.002) compared with those with lower MICA/B expression ( I 2 = 35%, P = 0.18). Serum soluble MICA/B represents a potential prognostic marker in various human cancers. High cell-surface MICA/B expression in cancers of the digestive system was found associated with increased survival.

  12. Application of spectroscopic methods to the study of ionizing radiation effects in polymers; Aplicacion de metodos espectroscopicos para estudiar efectos de la radiacion en polimeros

    Energy Technology Data Exchange (ETDEWEB)

    Jimenez P, G

    1996-12-31

    In general the interaction of ionizing radiation with polymers generates physic-chemical changes. Aiming to quantity these changes, three spectroscopic analytical techniques were used (UV, IR and EPR) and the chemical corrosion technique was used for three DSTN (CR39, Lexan and Makrofol) which were exposed to two radiation types: electrons and gammas. The effects of radiation are compared. Also a correlation between the UV and Vg results in function of dose is presented. The possible causes of the increase in chemical corrosion are discussed. (Author).

  13. Dinámica económica e institucionalización de la tributación directa. Trasnformaciones institucionales el caso de administración de impuestos 1920-1935

    Directory of Open Access Journals (Sweden)

    Oscar Rodríguez Salazar

    1999-01-01

    Full Text Available Las tres primeras décadas del presente siglo son el escenario de profundas transformaciones en la estructura económica del país y en el modelo institucional. El desarrollo de la economía cafetera, el acceso a la economía de crédito internacional, los cambios en la política económica, la ampliación de la infraestructura, el acelerado proceso de urbanización, los cambios demográficos, la proletarización de un contingente considerable de masas campesinas y el inicio del proceso de industrialización, marcan las mutaciones sufridas por la nación colombiana en su proceso de modernización.

  14. De crítico a escritor: Machado de Assis, leitor de Shakespeare

    Directory of Open Access Journals (Sweden)

    Vandemberg Simão Saraiva

    2012-10-01

    Full Text Available Machado de Assis foi leitor das peças de Shakespeare, e referências a essa leitura estão presentes em sua crítica dramática e literária. A compreensão de Machado das peças do dramaturgo inglês assumiu nova dinâmica a partir dos espetáculos shakespearianos promovidos por companhias italianas vindas ao Brasil a partir de 1871. Acreditamos que Machado de Assis encontrou na leitura de William Shakespeare muito do que precisava conhecer para produzir sua crítica e sua literatura. De leitor, Machado passa a crítico teatral e literário e escritor de sucesso.

  15. Nutrigenómica, obesidad y salud pública.

    Directory of Open Access Journals (Sweden)

    Manuela Belén Silveira

    2007-01-01

    Full Text Available El desarrollo de la genómica funcional en los próximos años condicionará cambios en el conocimiento teórico y la práctica clínica de la nutrición. La posibilidad de determinar el perfil genético de un individuo (variaciones genéticas y modificaciones epigenéticas y de conseguir la integración de estos datos en una compleja red de interacciones metabólicas constituye un desafío sin precedentes en la nutrición humana. La aplicación práctica del conocimiento científico puro derivado de la nutrigenómica, en términos de prevención y tratamiento de la obesidad, la DM2 y las enfermedades cardiovasculares, y sus implicaciones en la salud pública, son en este momento todavía indeterminadas. La posibilidad de una intervención nutricional en periodos críticos del desarrollo y la capacidad de modificar la susceptibilidad genética a ciertas enfermedades a través de la alimentación es el gran reto de la nutrigenómica, más allá del diseño de dietas o alimentos funcionales “personalizados”.

  16. Geoquímica e Geocronologia do Plutonismo Granítico Mesoproterozóico do SW do Estado de Mato Grosso (SW do Cráton Amazônico)

    OpenAIRE

    Mauro Cesar Geraldes

    2000-01-01

    O objetivo deste trabalho é o estudo geocronológico e da composição química dos granitóides da porção SW do estado do Mato Grosso. A abordagem deste projeto tem relevância para o entendimento da evolução geológica através da identificação, na área de estudo, de eventos de acresção crustal durante o Paleo e Mesoproterozóico que vieram a compor significativa fração do SW Cráton Amazônico. Na região do Terreno Jauru, tonalitos, vulcânicas ácidas e gnaisses analisados pelo método U/Pb em zircões ...

  17. One Dimensional Coordination Polymer of Zn(II) for Developing Multifunctional Nanoparticles.

    Science.gov (United States)

    Agarwal, Rashmi A

    2017-10-16

    A variety of nanoparticles (NPs) including Ag, Au, Pd, Cr and mixed Cu/Fe have been synthesized in a non-activated (without solvent removal) one dimensional coordination polymer (CP) of Zn(II) via two different mechanisms, acid formation and redox activity of the framework. Main driving force to grow these NPs within the cavities of CP is the presence of free oxygens of one of the monodentate carboxylate groups of BDC ligand. These free oxygens act as anchoring sites for the metal ions of the metal precursors. Chemical and physical characteristics of the NPs within the framework have been evaluated by the high resolution transmission electron microscopic (HRTEM) images. Excluding Ag(0) and Pd(0) other NPs are present as combinations of their elemental as well as oxide forms (Au/Au 2 O 3 , Cr/Cr 2 O 3 /CrO 2 and Cu/Cu 2 O, Fe/FeO). Synthesized Ag NPs within the framework show remarkable antibacterial efficacy at extremely low concentrations. Ag, Au and Cu/Fe NPs show ferromagnetic properties within the framework at room temperature. This polymer has potential to sequester highly toxic Cr(VI) to non toxic Cr(0), Cr(III) and Cr(IV) species.

  18. Feasibility study of extremity dosemeter based on polyallyl-diglycol-carbonate (CR-39) for neutron exposure

    International Nuclear Information System (INIS)

    Chau, Q.; Bruguier, P.

    2007-01-01

    In nuclear facilities, some activities such as reprocessing, recycling and production of bare fuel rods expose the workers to mixed neutron-photon fields. For several workplaces, particularly in glove boxes, some workers expose their hands to mixed fields. The mastery of the photon extremity dosimetry is relatively good, whereas the neutron dosimetry still raises difficulties. In this context, the Inst. for Radiological Protection and Nuclear Safety (IRSN) has proposed a study on a passive neutron extremity dosemeter based on chemically etched CR-39 (PADC: polyallyl-diglycol-carbonate), named PN-3, already used in routine practice for whole body dosimetry. This dosemeter is a chip of plastic sensitive to recoil protons. The chemical etching process amplifies the size of the impact. The reading system for tracks counting is composed of a microscope, a video camera and an image analyser. This system is combined with the dose evaluation algorithm. The performance of the dosemeter PN-3 has been largely studied and proved by several laboratories in terms of passive individual neutron dosemeter which is used in routine production by different companies. This study focuses on the sensitivity of the extremity dosemeter, as well as its performance in the function of the level of the neutron energy. The dosemeter was exposed to monoenergetic neutron fields in laboratory conditions and to mixed fields in glove boxes at workplaces. (authors)

  19. Calibration factor determination for solid nuclear track detectors CR-39 type exposed to Rn-222

    International Nuclear Information System (INIS)

    Cazula, Camila Dias; Campos, Marcia Pires de; Mazzilli, Barbara Paci

    2014-01-01

    In the detection method with solid nuclear track detector, when a heavy particle rests on the detector surface, causes a breakdown in their molecular structure forming a trace. One of the typical applications of these detectors is the measurement of the concentration of Rn -222 in air, a noble radioactive gas, part of the U-238 series, emitting alpha particles and important in epidemiological studies to protect individuals from natural radiation. To determine the concentration of Rn -222 in the air in a room is necessary to know the density of lines (traces / cm 2 ) on the detector surface, the exposure time and the calibration factor. The determination of the calibration factor for CR-39 detectors was taken from the exposure of these to a known concentration of Rn-222. Therefore, the detectors were placed inside a cell of Lucas adapted and subsequently exposed to a concentration of Rn-222 15 kBq / m 3 , by means of the apparatus RN-150 Pylon Electronics Incorporation, which has a source of Ra-226 and releases known concentrations of Rn-222. Six calibration factor determinations were performed, the average value obtained was 0.0534 ±0.0021 (traces / cm 2 per Bq / m 3 day). The results are consistent with literature values for the same type of detector and showed good reproducibility

  20. Study of a plastic detector as a neutron dosimeter

    International Nuclear Information System (INIS)

    Cuauhtecatl Hernandes, V.

    1982-01-01

    Studies were carried out through nuclear reactions (n, p); (n, heavy ion), and (n,α) of the dosimetric properties of CR 39 commercial brand polymers. A system was devised for calculating the number of neutron induced nuclear reactions and geometric absolute efficiency factors. Feasibility of the utilization of CR 39 in monitoring and in personnel dosimeters is also discussed. (author)

  1. Factors affecting the response of the bubble detector BD-100 and a comparison of its response to CR-39

    International Nuclear Information System (INIS)

    Ipe, N.E.; Busick, D.D.; Pollock, R.W.

    1987-08-01

    The BD-100 is a bubble detector available commercially from Chalk River Nuclear Laboratories, Canada for neutron dosimetry. According to the manufacturer, the BD-100 detects neutrons over an energy range of 100 keV to 14 MeV and the dose equivalent response is independent of energy. The sensitivity of the detector is dependent upon its temperature at the time of irradiation. The sensitized detector self-nucleates upon sharp impact and when heated to temperatures of 48 0 C or greater. The BD-100 is insensitive to low energy gamma rays but responds to 6 MeV photons. The sensitivity (bubbles/μSv) of the BD-100 was found to be energy dependent when exposed to standard neutron sources with average energies ranging from 0.5 to 4.5 MeV. The bubbles formed upon irradiation continued to grow in size with time. The response of electrochemically etched CR-39 to the same neutron sources is also reported for comparison

  2. Desigualdade no acesso a medicamentos para doenças crônicas em mulheres brasileiras

    Directory of Open Access Journals (Sweden)

    Flávia Katrein

    2015-07-01

    Full Text Available O objetivo deste trabalho foi analisar a prevalência de acesso a medicamentos para tratamento de doenças crônicas e a existência de desigualdades socioeconômicas no acesso. Os dados são da Pesquisa Nacional de Demografia e Saúde e da Mulher e da Criança de 2006, com uma amostra de 15.575 mulheres (15 a 49 anos. Dessas, 7.717 tiveram diagnóstico de doença crônica com necessidade de obtenção de medicamento e foram consideradas elegíveis para o estudo. O desfecho foi construído com base no diagnóstico de doença crônica e na necessidade de obtenção de medicamento para o tratamento. A análise ajustada foi conduzida usando-se a regressão de Poisson. Os grupos que apresentaram maior prevalência de acesso foram os domiciliados na zona rural, com uma ou duas doenças crônicas e com nível socioeconômico mais elevado. A prevalência de acesso encontrada foi alta, no entanto, as análises demonstram que existe desigualdade socioeconômica no acesso a medicamentos a favor dos mais ricos, identificando como grupo mais vulnerável aquele dos indivíduos mais pobres e com maior número de doenças crônicas.

  3. Interacción entre genes y nutrientes: nutrigenética y nutrigenómica

    OpenAIRE

    Cataño, Héctor C.

    2014-01-01

    Pocas décadas atrás varios estudios describieron bien la relación que existe entre los hábitos alimenticios y las enfermedades crónicas, por ello parte crítica de la estrategia de prevención de las enfermedades ha consistido en cambiar, los hábitos alimenticios. No obstante, no se ha tenido en consideración que los nutrientes provenientes de la dieta interaccionan con los genes. Gracias al desarrollo de la nutrigenética y nutrigenómica las recomendaciones dietéticas futuras tendrán en conside...

  4. Computer program for the sensitivity calculation of a CR-39 detector in a diffusion chamber for radon measurements

    Energy Technology Data Exchange (ETDEWEB)

    Nikezic, D., E-mail: nikezic@kg.ac.rs; Stajic, J. M. [Faculty of Science, University of Kragujevac, R. Domanovica 12, Kragujevac 34000 (Serbia); Yu, K. N. [Department of Physics and Materials Science, City University of Hong Kong, 83 Tat Chee Avenue (Hong Kong)

    2014-02-15

    Computer software for calculation of the sensitivity of a CR-39 detector closed in a diffusion chamber to radon is described in this work. The software consists of two programs, both written in the standard Fortran 90 programming language. The physical background and a numerical example are given. Presented software is intended for numerous researches in radon measurement community. Previously published computer programs TRACK-TEST.F90 and TRACK-VISION.F90 [D. Nikezic and K. N. Yu, Comput. Phys. Commun. 174, 160 (2006); D. Nikezic and K. N. Yu, Comput. Phys. Commun. 178, 591 (2008)] are used here as subroutines to calculate the track parameters and to determine whether the track is visible or not, based on the incident angle, impact energy, etching conditions, gray level, and visibility criterion. The results obtained by the software, using five different V functions, were compared with the experimental data found in the literature. Application of two functions in this software reproduced experimental data very well, while other three gave lower sensitivity than experiment.

  5. Distance distribution of bystander effects in alpha-particle irradiated cell populations using a CR-39-based culture dish

    International Nuclear Information System (INIS)

    Gaillard, S.; Pusset, D.; Toledo, S.M. de; Azzam, E.I.; Fromm, M.

    2008-01-01

    Propagation of induced biological effects from irradiated to non-irradiated cells is known to occur in cell cultures exposed to low fluences of charged particles. These bystander effects are currently investigated using microbeam or non-microbeam (broad beams) irradiation techniques. Identification of the targeted and non-targeted bystander cells is critical to our understanding of mechanisms underlying such effects. We developed a novel cell culture dish where the base consists of a thin CR-39 sheet grafted on a thin polyethylene terephthalate (PET) foil. The validity of this device in identifying not only irradiated cells, but also the cellular compartment traversed by the particle track is described. We have optimized track etch parameters that do not interfere with measurement of induced biological endpoints under normal incident irradiation. Thus the culture dishes can be used to determine distance distributions for the propagation of induced biological effects from a hit cell to bystander cells. We describe the computer code developed to determine the distance distributions of propagated biological stress responses in normal human fibroblast cells exposed to very low fluences of alpha particles

  6. Liberalização financeira, performance econômica e estabilidade macroeconômica no Brasil: uma avaliação do período 1994-2007

    Directory of Open Access Journals (Sweden)

    Luiz Fernando de Paula

    2013-05-01

    Full Text Available Este artigo objetiva avaliar a relação entre liberalização da conta capital, performance econômica e estabilidade macroeconômica no Brasil. Para tanto, além de uma revisão da literatura, o artigo realiza uma avaliação em-pírica dos efeitos da liberalização financeira no Brasil sobre um conjunto de variáveis macroeconômicas com o uso da metodologia VAR, utilizando, para tanto, dois modelos: um com um índice de jure de liberalização financeira (ILF, e outro com um índice de facto de integração financeira (IIF. Procura-se, no primeiro caso, avaliar a hipótese de que a liberalização financeira resulta em redução no risco país e, consequentemente, na taxa de juros doméstica; no segundo caso, avalia-se a hipótese de que a liberalização financeira tem impacto positivo sobre o crescimento econômico e a estabilidade macroeconômica vis-à-vis à hipótese dos críticos da liberalização financeira de que esta gera efeitos instabilizadores em países em desenvolvimento.

  7. Electrochemistry of conductive polymers 39. Contacts between conducting polymers and noble metal nanoparticles studied by current-sensing atomic force microscopy.

    Science.gov (United States)

    Cho, Shin Hyo; Park, Su-Moon

    2006-12-28

    Electrical properties of contacts formed between conducting polymers and noble metal nanoparticles have been examined using current-sensing atomic force microscopy (CS-AFM). Contacts formed between electrochemically prepared pi-conjugated polymer films such as polypyrrole (PPy), poly(3-methylthiophene) (P3MeT), as well as poly(3,4-ethylenedioxythiophene) (PEDOT) and noble metal nanoparticles including platinum (Pt), gold (Au), and silver (Ag) have been examined. The Pt nanoparticles were electrochemically deposited on a pre-coated PPy film surface by reducing a platinum precursor (PtCl62-) at a constant potential. Both current and scanning electron microscopic images of the film showed the presence of Pt islands. The Au and Ag nanoparticles were dispersed on the P3MeT and PEDOT film surfaces simply by dipping the polymer films into colloid solutions containing Au or Ag particles for specified periods (5 to approximately 10 min). The deposition of Au or Ag particles resulted from either their physical adsorption or chemical bonding between particles and the polymer surface depending on the polymer. When compared with PPy, P3MeT and PEDOT showed a stronger binding to Au or Ag nanoparticles when dipped in their colloidal solutions for the same period. This indicates that Au and Ag particles are predominantly linked with the sulfur atoms via chemical bonding. Of the two, PEDOT was more conductive at the sites where the particles are connected to the polymer. It appears that PEDOT has better aligned sulfur atoms on the surface and is strongly bonded to Au and Ag nanoparticles due to their strong affinity to gold and silver. The current-voltage curves obtained at the metal islands demonstrate that the contacts between these metal islands and polymers are ohmic.

  8. Alpha particle induced reactions on {sup nat}Cr up to 39 MeV: Experimental cross-sections, comparison with theoretical calculations and thick target yields for medically relevant {sup 52g}Fe production

    Energy Technology Data Exchange (ETDEWEB)

    Hermanne, A.; Adam Rebeles, R. [Cyclotron Laboratory, Vrije Universiteit Brussel, Brussel 1090 (Belgium); Tárkányi, F.; Takács, S. [Institute of Nuclear Research, Hungarian Academy of Science, 4026 Debrecen (Hungary)

    2015-08-01

    Thin {sup nat}Cr targets were obtained by electroplating, using 23.75 μm Cu foils as backings. In five stacked foil irradiations, followed by high resolution gamma spectroscopy, the cross sections for production of {sup 52g}Fe, {sup 49,51cum}Cr, {sup 52cum,54,56cum}Mn and {sup 48cum}V in Cr and {sup 61}Cu,{sup 68}Ga in Cu were measured up to 39 MeV incident α-particle energy. Reduced uncertainty is obtained by simultaneous remeasurement of the {sup nat}Cu(α,x){sup 67,66}Ga monitor reactions over the whole energy range. Comparisons with the scarce literature values and results from the TENDL-2013 on-line library, based on the theoretical code family TALYS-1.6, were made. A discussion of the production routes for {sup 52g}Fe with achievable yields and contamination rates was made.

  9. Study etching characteristics of a track detector CR-39 with ultraviolet laser irradiation

    International Nuclear Information System (INIS)

    Dwaikat, Nidal; Iida, Toshiyuki; Sato, Fuminobu; Kato, Yushi; Ishikawa, Ippei; Kada, Wataru; Kishi, Atsuya; Sakai, Makoto; Ihara, Yohei

    2007-01-01

    The effect of pulsed ultraviolet Indium-doped Yttrium Aluminum Garnet (UV-In:YAG) laser of λ=266 nm, pulse energy 42 mJ/pulse at repetition rate10 Hz on the etching characteristics of Japanese CR-39 was studied at various energy intensities. Fifteen detectors were divided into two sets, each of seven samples and one sample was kept as a reference.The first set (post-exposed) was first exposed to alpha radiation with close contact to 241 Am and then treated in air with laser in the energy intensity range from 40 to160 J/cm 2 , 20 J/cm 2 in step. The second set (pre-exposed) was irradiated in reverse process (laser+alpha) with the same sources as the first set and under the same condition. The laser energy intensities ranged between 20 and 140 J/cm 2 , 20 J/cm 2 in step. For post-exposed samples (alpha+laser) bulk etch rate decreases up to 60 J/cm 2 and increases thereafter, while for pre-exposed samples (laser+alpha) the bulk etch rate oscillates without showing any precise periodicity. The bulk etch rate for both sets was found to be the same at 60≤energy intensity≤80 J/cm 2 and this may indicate that the same structural changes have happened. The track etch rate was found to be equal to the bulk etch rate for both sets, so the sensitivity is constant. In both sets several changes on the detector surfaces: tracks of different sizes and shapes and high density within the laser spot were observed. Out of the laser spot, the tracks become larger and lower density, indicating cross-linking and scission have happened, simultaneously, on the same surface as a result of UV-laser irradiation

  10. Activity of Aniline Methylation over Fe-Cu-Cr Ternary Spinel Systems

    Directory of Open Access Journals (Sweden)

    Reni George

    2014-03-01

    Full Text Available A series of spinels having thegeneral formula CuCr2-xFexO4 with x=0.25,0.75, 1.25, 1.75 were prepared by co-precipitation method. The catalysts werecharacterized by various physico-chemical methods like XRD, BET, UV-DRS, SEM,EDX, TPD etc. The reaction of aniline with methanol was studied in a fixed-bedreactor system as a potential source for the production of various methylanilines. It was observed that systems possessing low ‘x’ values are highlyselective and active for N-monoalkylation of aniline leading toN-methylaniline. Reaction parameters were properly varied to optimize thereaction conditions for obtaining N-methylaniline selectively and in betteryield. Among the systems CuCr1.75Fe0.25O4 isremarkable due to its very high activity and excellent stability. Under theoptimized conditions N-methylaniline selectivity exceeded 91%. CuCr1.25Fe0.75O4gives better conversion than CuCr1.75Fe0.25O4in CuCr2-xFexO4 series. The Lewis acid sitesof the catalysts are mainly responsible for the good catalytic performance. © 2014 BCREC UNDIP. All rights reservedSubmitted: 18th July 2013; Revised: 5th November 2013; Accepted: 1st December 2013[How to Cite: George, R., George, K., Sugunan, S. (2014. Activity of Aniline Methylation over Fe-Cu-Cr Ternary Spinel Systems. Bulletin of Chemical Reaction Engineering & Catalysis, 9 (1: 39-44. (doi:10.9767/bcrec.9.1.5169.39-44][Permalink/DOI: http://dx.doi.org/10.9767/bcrec.9.1.5169.39-44] 

  11. Track profile and range studies of heavy and light ions in CR-39: effect of thermal pre-treatment on etching characteristics

    International Nuclear Information System (INIS)

    Al-Najjar, S.A.R.; Bull, R.K.; Durrani, S.A.

    1982-01-01

    Sheets of CR 39 have been irradiated with 20 Ne, 32 S, 40 Ar, 56 Fe and 63 Cu ions at normal incidence to the surface of the sheets and at normal incidence to the edges. The profiles of the etched tracks have been observed side-on and measurements made of the variation of V (the ratio of track to bulk etching velocities) along the tracks and of the fully etched range of the tracks. Heating the plastic at 100 0 C prior to etching produces zones within the plastic having different bulk etching rates Vsub(B). An outer zone of low Vsub(B) is followed by a zone of much higher Vsub(B). This allows tracks to be readily etched to very large diameters, comparable in size to the breakdown spots produced by electrochemical etching. (author)

  12. Bioaccumulation and subcellular partitioning of Cr(III) and Cr(VI) in the freshwater green alga Chlamydomonas reinhardtii

    Energy Technology Data Exchange (ETDEWEB)

    Aharchaou, Imad [Laboratoire Interdisciplinaire des Environnements Continentaux, UMR 7360, Université de Lorraine and CNRS, 8 rue du Général Delestraint, 57070 Metz (France); Rosabal, Maikel; Liu, Fengjie [Institut National de la Recherche Scientifique, Centre Eau Terre Environnement (INRS-ETE), 490 rue de la Couronne, Québec (Québec) G1K 9A9 (Canada); Battaglia, Eric; Vignati, Davide A.L. [Laboratoire Interdisciplinaire des Environnements Continentaux, UMR 7360, Université de Lorraine and CNRS, 8 rue du Général Delestraint, 57070 Metz (France); Fortin, Claude, E-mail: claude.fortin@ete.inrs.ca [Institut National de la Recherche Scientifique, Centre Eau Terre Environnement (INRS-ETE), 490 rue de la Couronne, Québec (Québec) G1K 9A9 (Canada)

    2017-01-15

    Highlights: • C. reinhardtii accumulated similar levels of Cr(III) and Cr(VI). • The subcellular partitioning of Cr(III) and Cr(VI) was similar. • Cr(III) and Cr(VI) associated mainly with organelles and heat-stable proteins. • Metallomic analysis showed two main Cr-binding biomolecules after 72 h of exposure. - Abstract: Chromium occurs in aquatic environments under two main redox forms, namely Cr(III) and Cr(VI), with different geochemical and biochemical properties. Cr(VI) readily crosses biological membranes of living organisms and once inside the cells it undergoes a rapid reduction to Cr(III). The route of entry for the latter form is, however, poorly known. Using the radioactive tracer {sup 51}Cr we compared the accumulation (absorption and adsorption) of the two Cr forms by the green unicellular alga Chlamydomonas reinhardii after 1 h and 72 h of exposure to 100 nM of either Cr(III) or Cr(VI) at pH 7. Both Cr forms had similar accumulation, with a major part in the extracellular (adsorbed) fraction after 1 h and a major part of total accumulated Cr in the intracellular (absorbed) fraction after 72 h. We also investigated the intracellular partitioning of Cr using an operational fractionation scheme and found that both Cr forms had similar distributions among fractions: Cr was mostly associated with organelles (23 ± 12% after 1 h and 37 ± 7% after 72 h) and cytosolic heat-stable proteins and peptides (39 ± 18% after 1 h and 35 ± 3% after 72 h) fractions. Further investigations using a metallomic approach (SEC-ICP-MS) were performed with the heat-stable proteins and peptides fraction to compare the distribution of the two Cr forms among various biomolecules of this fraction. One Cr-binding biomolecule (∼28 kDa) appeared after 1 h of exposure for both Cr species. After 72 h another biomolecule of lower molecular weight (∼0.7 kDa) was involved in binding Cr and higher signal intensities were observed for Cr(VI) than for Cr(III). We show, for the

  13. Bioaccumulation and subcellular partitioning of Cr(III) and Cr(VI) in the freshwater green alga Chlamydomonas reinhardtii

    International Nuclear Information System (INIS)

    Aharchaou, Imad; Rosabal, Maikel; Liu, Fengjie; Battaglia, Eric; Vignati, Davide A.L.; Fortin, Claude

    2017-01-01

    Highlights: • C. reinhardtii accumulated similar levels of Cr(III) and Cr(VI). • The subcellular partitioning of Cr(III) and Cr(VI) was similar. • Cr(III) and Cr(VI) associated mainly with organelles and heat-stable proteins. • Metallomic analysis showed two main Cr-binding biomolecules after 72 h of exposure. - Abstract: Chromium occurs in aquatic environments under two main redox forms, namely Cr(III) and Cr(VI), with different geochemical and biochemical properties. Cr(VI) readily crosses biological membranes of living organisms and once inside the cells it undergoes a rapid reduction to Cr(III). The route of entry for the latter form is, however, poorly known. Using the radioactive tracer "5"1Cr we compared the accumulation (absorption and adsorption) of the two Cr forms by the green unicellular alga Chlamydomonas reinhardii after 1 h and 72 h of exposure to 100 nM of either Cr(III) or Cr(VI) at pH 7. Both Cr forms had similar accumulation, with a major part in the extracellular (adsorbed) fraction after 1 h and a major part of total accumulated Cr in the intracellular (absorbed) fraction after 72 h. We also investigated the intracellular partitioning of Cr using an operational fractionation scheme and found that both Cr forms had similar distributions among fractions: Cr was mostly associated with organelles (23 ± 12% after 1 h and 37 ± 7% after 72 h) and cytosolic heat-stable proteins and peptides (39 ± 18% after 1 h and 35 ± 3% after 72 h) fractions. Further investigations using a metallomic approach (SEC-ICP-MS) were performed with the heat-stable proteins and peptides fraction to compare the distribution of the two Cr forms among various biomolecules of this fraction. One Cr-binding biomolecule (∼28 kDa) appeared after 1 h of exposure for both Cr species. After 72 h another biomolecule of lower molecular weight (∼0.7 kDa) was involved in binding Cr and higher signal intensities were observed for Cr(VI) than for Cr(III). We show, for the

  14. Microstructure, state of internal stress and corrosion resistance of the short-time laser heat-treated nitrogen high-alloyed tool steel X30CrMoN151; Mikrostruktur, Eigenspannungszustand und Korrosionsbestaendigkeit des kurzzeitlaserwaermebehandelten hochstickstofflegierten Werkzeugstahls X30CrMoN151

    Energy Technology Data Exchange (ETDEWEB)

    Bohne, C. (ed.)

    2000-07-01

    This study compares the crystalline structure, state of internal stress and chemical properties of the high-alloyed nitrogen tool steel X30CrMoN15 1 and conventional cold work steel X39CrMo17 1. Transformation points A{sub c}1b and A{sub c}1e were calculated from residual austenite analysis and the c{sub m}/a{sub m} martensite ratios for various heating rates. This was used to generate a TTA (time-temperature-austenitisation) graph for X30CrMoN15 1 for the first time. Transmission electron microscopy and small-angle neutron scattering show that precipitates in nitrogen high-alloyed steel X30CrMoN15 1 can be eliminated completely by short-time laser heat treatment. The corrosion tests show that in contrast to X39CrMo17 1 X30CrMoN15 1 reacts more sensitively to parameter changes during short-time heat treatment in oxidising acid at pH 5-6. [German] Im Rahmen der Arbeit werden die Gefuegeausbildung, Eigenspannungen und chemische Eigenschaften des hochstickstofflegierten Werkzeugstahls X30CrMoN15 1 und des konventionellen Kaltarbeitsstahls X39CrMo17 1 verglichen. Aus den Restaustenitanalysen und den c{sub m}/a{sub m}-Verhaeltnissen des Martensits konnten die Umwandlungspunkte A{sub c1b} und A{sub c1e} fuer verschiedene Aufheizraten bestimmt und daraus ein bisher nicht bekanntes ZTA-Schaubild fuer den X30CrMoN15 1 erstellt werden. Transmissionselektronenmikroskopie und Neutronenkleinwinkelstreuung zeigen, dass sich die Ausscheidungen im hochstickstofflegierten Stahl X30CrMoN14 1 durch die Kurzzeitlaserwaermebehandlung vollstaendig aufloesen koennen. Die Korrosionsversuche zeigen, dass im Gegensatz zum X39CrMo17 1 der X30CrMoN15 1 in oxidierender Saeure bei pH 5-6 empfindlicher auf Parameteraenderungen bei der Kurzzeitwaermebehandlung reagiert. (orig.)

  15. VULNERABILIDADE NO DESENVOLVIMENTO DA CRIANÇA: INFLUÊNCIA DOS ELOS FAMILIARES FRACOS, DEPENDÊNCIA QUÍMICA E VIOLÊNCIA DOMÉSTICA

    Directory of Open Access Journals (Sweden)

    Daniel Ignacio da Silva

    2014-01-01

    Full Text Available Investigación exploratoria cualitativa que objetivó conocer la comprensión del enfermero sobre la vulnerabilidad en el desarrollo del niño. Los sujetos fueron 39 enfermeros que trabajan en 39 Unidades de Salud en Curitiba, Paraná, Brasil. Los datos fueron obtenidos por medio de entrevistas semi-estructuradas, y analizados por la hermenéutica dialéctica. Los resultados apuntaron, según los enfermeros, que la vulnerabilidad del niño es influida por los eslabones familiares débiles, por la dependencia química y violencia doméstica. Los sujetos de la investigación relatan la expresión de procesos individuales como reflejos de la sociedad posmoderna y comprenden esta relación sociedad-familia como situación adversa al desarrollo infantil. La utilización del concepto de vulnerabilidad en el cotidiano profesional del enfermero y del equipo de Salud, permite un análisis crítico de sus prácticas. La aplicación de este concepto en el cuidado al niño propicia la reorientación del modelo asistencial, y así, la superación del concepto biologicista y fragmentado de desarrollo infantil.

  16. Development of PNTDs synthesized from monomers with different molecular length and analysis of molecular damages by heavy ion

    International Nuclear Information System (INIS)

    Kawashima, Hajime; Kodaira, Satoshi; Ihara, Daisuke; Yasuda, Nakahiro; Kusumoto, Tamon; Mori, Yutaka; Yamauchi, Tomoya; Kobayashi, Keiichi; Benton, Eric

    2017-01-01

    Our interests for years lay to investigate the reason why CR-39 polymer has such high sensitivity as plastic nuclear track detector (PNTD) on chemical structural aspects. We developed three PNTDs from three diacrylate compounds as monomers bearing different molecular length as well as different numbers of internal ether bonds. The polymer products obtained were colorless and transparent with 3-D molecular structures as CR-39 and different lattice structures each other. Our purpose of the current study was to investigate structural damages caused in newly prepared PNTDs and CR-39 by irradiation of Nitrogen ion (6 MeV/n, fluence of 5 x 10 11 cm -2 ). The structural damage by irradiation was analyzed by the magnitude of the relative absorbance of specific functional groups such as ester, C=O, ether and C-H bonds by means of FT-IR (ATR) method. The correlation between the relative absorbance and the molecular length of the monomers were discussed. (author)

  17. Imaging of fast-neutron sources using solid-state track-recorder pinhole radiography

    International Nuclear Information System (INIS)

    Ruddy, F.H.; Gold, R.; Roberts, J.H.; Kaiser, B.J.; Preston, C.C.

    1983-08-01

    Pinhole imaging methods are being developed and tested for potential future use in imaging the intense neutron source of the Fusion Materials Irradiation Test (FMIT) Facility. Previously reported, extensive calibration measurements of the proton, neutron, and alpha particle response characteristics of CR-39 polymer solid state track recorders (SSTRs) are being used to interpret the results of imaging experiments using both charged particle and neutron pinhole collimators. High resolution, neutron pinhole images of a 252 Cf source have been obtained in the form of neutron induced proton recoil tracks in CR-39 polymer SSTR. These imaging experiments are described as well as their potential future applications to FMIT

  18. CULTURAS ACADÉMICAS: ENTRE REINVENCIÓN Y CONTRABANDO

    Directory of Open Access Journals (Sweden)

    Kathya Araujo

    2015-01-01

    Full Text Available Sobre la base del análisis de una historia personal de desplazamiento entre academias (peruana y chilena, y la reinvención y el contrabando que toda migración supone, este artículo argumenta de qué manera frente a las nuevas modalidades de evaluación (los rankings, la búsqueda de isomorfismo de las estructuras argumentativas y las formas lingüísticas o incluso la ficción de sociologías globales, se mantienen vivas culturas académicas particulares. En este marco, la reflexión se organiza mostrando que detrás de la singularidad de los estilos intelectuales, formas de sociabilidad profesionales e incluso formas lingüísticas de cada una de ellas, lo que se revela es la manera en la que cada cultura académica local responde desde tradiciones diversas a desafíos político sociales distintos y con ello su rol de compromiso público y crítico.

  19. Síndrome de Pyle com fragmentação cromossômica

    Directory of Open Access Journals (Sweden)

    Aron J. Diament

    1971-03-01

    Full Text Available É relatado o caso de uma paciente com síndrome de Pyle (displasia crâniometafisária, com sintomatologia de involução neuropsíquica, progressiva e sinais pirâmido-extrapiramidais. O estudo do cariótipo revelou a presença, em 12% das células, de fragmentação cromossômica, embora a análise da genealogia do propósito revelasse tratar-se de provável moléstia recessiva. São discutidas as hipóteses dos mecanismos da fragmentação cromossômica em tais eventualidades (moléstias recessivas, concluindo-se por provável fragmentação secundária no caso em questão.

  20. Análise de 39 casos de pneumonia intersticial crônica idiopática Analysis of 39 cases of idiopathic chronic interstitial pneumonia

    Directory of Open Access Journals (Sweden)

    Rogério Rufino

    2006-12-01

    Full Text Available OBJETIVO: Analisar de forma retrospectiva fragmentos de biópsias pulmonares que receberam o diagnóstico de pneumonia intersticial crônica idiopática, à luz da classificação da American Thoracic Society e European Respiratory Society, de 2000. MÉTODOS: A partir da revisão de 252 fragmentos de biópsias pulmonares a céu aberto de pacientes com doença intersticial pulmonar, no período de 1977 a 1999, 39 casos de doença pulmonar intersticial idiopática foram selecionados e reavaliados por dois patologistas, segundo a classificação da American Thoracic Society e European Respiratory Society, de 2000. RESULTADOS: Vinte e oito dos 39 diagnósticos foram mantidos (71,8%. Uma nova entidade patológica, a pneumonia intersticial não específica, foi incluída na reclassificação e houve superposição de padrões em seis casos. Mantiveram o mesmo diagnóstico 28 casos, 4 casos apresentaram associação entre fibrose pulmonar idiopática e organização pneumônica criptogênica, 1 entre organização pneumônica criptogênica e pneumonia intersticial não específica, e 1 entre pneumonia intersticial descamativa e pneumonia intersticial não específica. Todos os casos de fibrose pulmonar idiopática foram confirmados, embora 3 deles estivessem associados a organização pneumônica criptogênica. Os diagnósticos anteriores foram quase todos mantidos na revisão dos espécimes (p > 0,05. CONCLUSÃO: A classificação das doenças pulmonares intersticiais da American Thoracic Society e European Respiratory Society é uma ferramenta útil aos patologistas que lidam com biópsias pulmonares.OBJECTIVE: To make a retrospective analysis of lung biopsy samples obtained from patients diagnosed with chronic idiopathic interstitial pneumonia, as defined in the American Thoracic Society/European Respiratory Society classification system made public in 2000. METHODS: Samples from 252 open-lung biopsies of patients with interstitial lung disease, all

  1. Culturas académicas: entre reinvención y contrabando

    Directory of Open Access Journals (Sweden)

    Kathya Araujo

    2015-03-01

    Full Text Available Sobre la base del análisis de una historia personal de desplazamiento entre academias (peruana y chilena, y la reinvención y el contrabando que toda migración supone, este artículo argumenta de qué manera frente a las nuevas modalidades de evaluación (los rankings, la búsqueda de isomorfismo de las estructuras argumentativas y las formas lingüísticas o incluso la ficción de sociologías globales, se mantienen vivas culturas académicas particulares. En este marco, la reflexión se organiza mostrando que detrás de la singularidad de los estilos intelectuales, formas de sociabilidad profesionales e incluso formas lingüísticas de cada una de ellas, lo que se revela es la manera como cada cultura académica local responde desde tradiciones diversas a desafíos político sociales distintos y con ello su rol de compromiso público y crítico.

  2. 51Cr diffusion in Zr-Sn alloys

    International Nuclear Information System (INIS)

    Nicolai, L.I.; Migoni, R.L.; Hojvat de Tendler, Ruth

    1982-01-01

    The 51 Cr volume diffusion in Zr-Sn alloys is measured in polycrystals with big grains by the thin-film method. The Sn content in the alloys ranges from 0.39% at to 6.66 % at. In the beta-phase the analysed temperature range is 982 deg C-1240 deg C. The Sn dehances the 51 Cr diffusion in beta-Zr, the effect being small but well defined. Assuming the formation of Sn-Cr dimers, the linear dehancement coefficient b and the parameters for the variation of b with temperature were calculated. The parameters Q and D o were calculated for the more diluted alloys and, upon application of the Zener theory for D o , a negative contribution to the activation entropy is found. Three experiments at different temperatures were performed in the alpha-phase. 51 Cr diffuses very fast in alpha-Zr-Sn. No definite correlation is found between the 51 Cr diffusivity and the increasing Sn concentration, probably due to the anisotropy of the alfa-phase. (M.E.L.) [es

  3. Poly(styrene-co-butadiene) random copolymer thin films and nanostructures on a mica surface: morphology and contact angles of nanodroplets.

    Science.gov (United States)

    McClements, Jake; Buffone, Cosimo; Shaver, Michael P; Sefiane, Khellil; Koutsos, Vasileios

    2017-09-20

    The self-assembly of poly(styrene-co-butadiene) random copolymers on mica surfaces was studied by varying solution concentrations and polymer molecular weights. Toluene solutions of the poly(styrene-co-butadiene) samples were spin coated onto a mica surface and the resulting polymer morphology was investigated by atomic force microscopy. At higher concentrations, thin films formed with varying thicknesses; some dewetting was observed which depended on the molecular weight. Total dewetting did not occur despite the polymer's low glass transition temperature. Instead, partial dewetting was observed suggesting that the polymer was in a metastable equilibrium state. At lower concentrations, spherical cap shaped nanodroplets formed with varying sizes from single polymer chains to aggregates containing millions of chains. As the molecular weight was increased, fewer aggregates were observed on the surface, albeit with larger sizes resulting from increased solution viscosities and more chain entanglements at higher molecular weights. The contact angles of the nanodroplets were shown to be size dependent. A minimum contact angle occurs for droplets with radii of 100-250 nm at each molecular weight. Droplets smaller than 100 nm showed a sharp increase in contact angle; attributed to an increase in the elastic modulus of the droplets, in addition, to a positive line tension value. Droplets larger than 250 nm also showed an increased contact angle due to surface heterogeneities which cannot be avoided for larger droplets. This increase in contact angle plateaus as the droplet size reaches the macroscopic scale.

  4. Labor crítica del periodismo

    Directory of Open Access Journals (Sweden)

    Umberto Eco

    2015-01-01

    Full Text Available Señala que la función del cuarto Poder es la de controlar y criticar a los poderes tradicionales, esta crítica no tiene funciones represivas: los medios pueden influir en la vida política del país solamente creando opinión. Los poderes tradicionales, tampoco pueden controlar, criticando a los medios sino a través de los mismos medios, de otra manera su intervención se convierte en sanción ejecutiva, legislativa o judicial. Habla sobre la polémica que suscita el término "objetividad" y sobre la "tematización".

  5. Evolução do crédito industrial no Brasil: uma análise a partir de fatores macroeconômicos

    Directory of Open Access Journals (Sweden)

    Pâmela Amado Tristão

    2015-04-01

    Full Text Available O objetivo deste trabalho consistiu em analisar a influência das variáveis macroeconômicas sobre o crédito industrial no Brasil, no período pós-estabilização. Essa discussão tem como cenário, de um lado, a trajetória descendente do crédito industrial nos anos recentes e, de outro, as políticas expansionistas destinadas à indústria. Para o alcance dos objetivos, foi estimado um modelo de correção de erros com o qual foi possível analisar as dinâmicas de longo e de curto prazo. Os resultados apontam para a recorrente influência da taxa de câmbio e do produto agregado na explicação do comportamento das operações de crédito industrial na economia brasileira, tanto no curto quanto no longo prazo. Além disso, salientam-se os efeitos mais prolongados do produto sobre o crédito industrial, enquanto que as variáveis de política, à exceção do câmbio, apresentaram efeitos temporários.

  6. EFECTO DEL CONTENIDO DE CARBONO SOBRE LA RESISTENCIA AL DESGASTE ABRASIVO DE RECUBRIMIENTOS DE CrC DEPOSITADOS POR PULVERIZACIÓN CATÓDICA MAGNETRÓN EFEITO DO CONTEÚDO DE CARBONO SOBRE A RESISTÊNCIA AO DESGASTE ABRASIVO DE RECOBRIMENTOS DE CrC DEPOSITADOS POR PULVERIZAÇÃO CATÓDICA MAGNETRÃO EFFECT OF THE CARBON CONTENT IN ABRASIVE WEAR RESISTANCE OF CrC COATINGS DEPOSITED BY MAGNETRON SPUTTERING

    Directory of Open Access Journals (Sweden)

    Maryory Astrid Gómez

    2012-12-01

    Full Text Available Los recubrimientos de carburo de cromo sobre acero son un buen candidato para aplicaciones de conformado y moldes de inyección. La alta resistencia mecánica, resistencia química y estabilidad a alta temperatura de la fase Cr3C2 pueden ser compatibles con el intenso desgaste abrasivo y la corrosión en tales operaciones de fabricación. En este trabajo se depositaron recubrimientos de CrC por pulverización catódica magnetrón RF, los cuales mostraron contenidos de carbono entre el 25 % y el 58 % por análisis EDS. Los valores de dureza de estos recubrimientos fueron entre 15 y 24 GPa; los más duros de las muestras tuvieron contenido de carbono en el rango de 39-53 %. El desgaste abrasivo de los recubrimientos se evaluó utilizando un equipo de disco abrasivo con polvo de diamante. El volumen de las huellas de abrasión se midió con las imágenes obtenidas en el microscopio interferométrico y además se corroboró con el cálculo del volumen geométrico basado en secciones medidas con el perfilómetro. El comportamiento al desgaste abrasivo mostró una marcada dependencia con el contenido de carbono. El desgaste abrasivo más bajo se obtuvo para los recubrimientos con el más alto contenido de carbono.Os recobrimentos de carburo de cromo sobre aço são um bom candidato para aplicações de conformado e moldes de injeção. A alta resistência mecânica, resistência química e estabilidade em alta temperatura da fase Cr3C2 podem ser compatíveis com o intenso desgaste abrasivo e a corrosão em tais operações de fabricação. Neste trabalho depositaram-se recobrimentos de CrC por pulverização catódica magnetrão RF, os quais mostraram conteúdos de carbono entre 25 % e 58 % por análise EDS. Os valores de dureza destes recobrimentos foram entre 15 e 24 GPa; os mais duros das mostras tiveram conteúdo de carbono na faixa de 39-53 %. O desgaste abrasivo dos recobrimentos avaliou-se utilizando uma equipe de disco abrasivo com pó de

  7. Self-Assembling of Tetradecylammonium Chain on Swelling High Charge Micas (Na-Mica-3 and Na-Mica-2): Effect of Alkylammonium Concentration and Mica Layer Charge.

    Science.gov (United States)

    Pazos, M Carolina; Cota, Agustín; Osuna, Francisco J; Pavón, Esperanza; Alba, María D

    2015-04-21

    A family of tetradecylammonium micas is synthesized using synthetic swelling micas with high layer charge (Na(n)Si(8-n)Al(n)Mg6F4O20·XH2O, where n = 2 and 3) exchanged with tetradecylammonium cations. The molecular arrangement of the surfactant is elucidated on the basis of XRD patterns and DTA. The ordering conformation of the surfactant molecules into the interlayer space of micas is investigated by IR/FT, (13)C, (27)Al, and (29)Si MAS NMR. The structural arrangement of the tetradecylammonium cation in the interlayer space of high-charge micas is more sensitive to the effect of the mica layer charge at high concentration. The surfactant arrangement is found to follow the bilayer-paraffin model for all values of layer charge and surfactant concentration. However, at initial concentration below the mica CEC, a lateral monolayer is also observed. The amount of ordered conformation all-trans is directly proportional to the layer charge and surfactant concentration.

  8. Sobre o estatuto epistemológico da racionalidade econômica segundo Karl Popper

    Directory of Open Access Journals (Sweden)

    Brena Paula Magno Fernandez

    2014-12-01

    Full Text Available Três tipos de críticas são comumente levantadas contra a utilização do postulado da racionalidade na ciência econômica. A primeira delas associa-se ao argumento da circularidade, a segunda diz respeito à blindagem da teoria contra a refutação e a terceira - e mais importante delas - refere-se à inadequação empírica. O presente artigo busca encaminhar esta última, à luz do tratamento dado por Popper ao longo de sua carreira para a questão de qual seria o estatuto epistemológico do princípio da racionalidade nas teorias econômicas. Três possíveis respostas a esta questão são aqui examinadas, explicitando-se suas respectivas estruturas lógicas. A primeira delas propõe que o postulado da racionalidade desempenhe o papel de lei geral do comportamento humano. A segunda requer que ele funcione como um axioma da teoria. Finalmente, a terceira proposta sugere que o postulado da racionalidade seja entendido como regra metodológica. Conclui-se o artigo sugerindo que esta última solução satisfaz ao apelo que o tipo de crítica aqui examinada faz ao conceito de racionalidade. Não obstante, ao situar-se no contexto metateórico, o postulado da racionalidade mantém importância inegável na teoria econômica. Sem ele, não se disporia de instrumentos que conduzissem à seleção de dados empíricos voltados ao teste das teorias.

  9. Actualización sobre estreñimiento crónico funcional en niños

    OpenAIRE

    Carlos Alberto Velasco

    2005-01-01

    El estreñimiento crónico es un problema frecuente en la edad pediátrica; 95% de los casos es funcional, es decir, no debido a causas orgánicas, anatómicas o por ingesta de alimentos. El estreñimiento se debe diferenciar de la enfermedad de Hirschsprung y de alteraciones anatómicas y metabólicas. La evaluación clínica incluye una historia clínica completa, examen físico adecuado y paraclínicos como radiología, manometría anorrectal y biopsia rectal. El manejo incluye cambios en el medio ambien...

  10. Poluição fotoquímica na costa portuguesa

    OpenAIRE

    Evtyugina, Margarita Guennadievna

    2004-01-01

    A zona costeira Portuguesa é uma região complexa que se encontra sob a influência, quer de fenómenos naturais, como por exemplo as brisas costeiras, quer da actividade humana. Os estudos anteriormente realizados na Europa e os conhecimentos actuais apontam Portugal, particularmente a zona costeira como uma área crítica onde se prevê que nos próximos anos seja difícil atingir os objectivos de equilíbrio ambiental em relação aos efeitos da poluição fotoquímica [Comissão Europe...

  11. La enseñanza de la química desde el modelo integrado de aprendizaje profundo, MIAP. Fortalezas y debilidades

    Directory of Open Access Journals (Sweden)

    Johanna Camacho

    2009-09-01

    Full Text Available En este análisis crítico del Modelo Integrado de Aprendizaje Profundo, MIAP, se presentan algunos fundamentos teóricos del modelo, a partir de lo trabajado por el equipo de la Facultad de Educación de la Universidad Católica de Chile. Posteriormente, se reconocen algunas fortalezas y debilidades para la enseñanza de la química y se presentan algunos aspectos que pueden considerarse con el fin de mejorar las prácticas educativas de los profesores de química de enseñanza básica y media.

  12. Conducción nerviosa en niños con insuficiencia renal crónica

    OpenAIRE

    Dania Fuentes Martínez; Roberto Tomás Álvarez Fumero; Olga Noemí Levis; Carlos Santos Anzorandia; Ricardo Batista Moliner

    2002-01-01

    La polineuropatía urémica es la complicación neurológica más frecuente de la insuficiencia renal crónica, y son insuficientemente conocidos su prevalencia, síntomas y patrones neurofisiológicos de expresión en la población pediátrica. Es por ello que se estudiaron 23 pacientes en edades comprendidas entre 7 y 21 años, con insuficiencia renal crónica en sus diferentes grados y 23 niños supuestamente sanos, buscando la presencia de neuropatía periférica clínica o subclínica. Se realizó examen f...

  13. Arm retraction dynamics of entangled star polymers: A forward flux sampling method study

    Science.gov (United States)

    Zhu, Jian; Likhtman, Alexei E.; Wang, Zuowei

    2017-07-01

    The study of dynamics and rheology of well-entangled branched polymers remains a challenge for computer simulations due to the exponentially growing terminal relaxation times of these polymers with increasing molecular weights. We present an efficient simulation algorithm for studying the arm retraction dynamics of entangled star polymers by combining the coarse-grained slip-spring (SS) model with the forward flux sampling (FFS) method. This algorithm is first applied to simulate symmetric star polymers in the absence of constraint release (CR). The reaction coordinate for the FFS method is determined by finding good agreement of the simulation results on the terminal relaxation times of mildly entangled stars with those obtained from direct shooting SS model simulations with the relative difference between them less than 5%. The FFS simulations are then carried out for strongly entangled stars with arm lengths up to 16 entanglements that are far beyond the accessibility of brute force simulations in the non-CR condition. Apart from the terminal relaxation times, the same method can also be applied to generate the relaxation spectra of all entanglements along the arms which are desired for the development of quantitative theories of entangled branched polymers. Furthermore, we propose a numerical route to construct the experimentally measurable relaxation correlation functions by effectively linking the data stored at each interface during the FFS runs. The obtained star arm end-to-end vector relaxation functions Φ (t ) and the stress relaxation function G(t) are found to be in reasonably good agreement with standard SS simulation results in the terminal regime. Finally, we demonstrate that this simulation method can be conveniently extended to study the arm-retraction problem in entangled star polymer melts with CR by modifying the definition of the reaction coordinate, while the computational efficiency will depend on the particular slip-spring or slip

  14. The effects of pre-etching time on the characteristic responses of electrochemically etched CR-39 neutron dosimeters

    International Nuclear Information System (INIS)

    Sohrabi, M.; Khoshnoodi, M.

    1986-01-01

    The effects of pre-etching time (PET) or duration of etching of fast-neutron-induced-recoil tracks in CR-39 in 6N KOH at 60 0 C on electrochemical etching neutron characteristic responses; i.e. sensitivity and mean recoil track diameter (MRTD) versus KOH normality up to 18N are investigated in this paper. Six sets of responses for PETs of 0, 1, 2, 3, 4, and 5 hours were obtained by using our new multi-chamber ECE (MCECE) system which reduced total operation time to about 6% of the time usually required when single-chamber ECE systems are used. The sensitivity response for zero PET showed a broad plateau and a high sensitivity low-LET peak around 16N. By increasing PET, another peak was also developed around 5N leading to 'double-humped' responses with two maximums around 5N and 16N, and a minimum around 11N. On the other hand, the MRTD responses for all PETs studied showed the same general trend with maximums around 11N. In this paper, shape of tracks under different conditions are also investigated, new optimum conditions such as KOH concentrations of 5, 11, and 15N at 25 0 C, with or without pre-etching, are recommended for tracks of lower-LET recoils including possibly protons, and alpha particle tracks over a broad energy range, and the efficiency of the MCECE system is also demonstrated. (author)

  15. 3D computation of the shape of etched tracks in CR-39 for oblique particle incidence and comparison with experimental results

    International Nuclear Information System (INIS)

    Doerschel, B.; Hermsdorf, D.; Reichelt, U.; Starke, S.; Wang, Y.

    2003-01-01

    Computation of the shape of etch pits needs to know the varying track etch rate along the particle trajectories. Experiments with alpha particles and 7 Li ions entering CR-39 detectors under different angles showed that this function is not affected by the inclination of the particle trajectory with respect to the normal on the detector surface. Track formation for oblique particle incidence can, therefore, be simulated using the track etch rates determined for perpendicular incidence. 3D computation of the track shape was performed applying a model recently described in literature. A special program has been written for computing the x,y,z coordinates of points on the etch pit walls. In addition, the etch pit profiles in sagittal sections as well as the contours of the etch pit openings on the detector surface have been determined experimentally. Computed and experimental results were in good agreement confirming the applicability of the 3D computational model in combination with the functions for the depth-dependent track etch rates determined experimentally

  16. Resistencia a la corrosión a alta temperatura de recubrimientos NiCrAlY y NiCrFeNbMoTiAl depositados por APS

    Directory of Open Access Journals (Sweden)

    José Luis Tristancho-Reyes

    2014-12-01

    Full Text Available La corrosión a alta temperatura de las tuberías utilizadas en equipos generadores de vapor (calderas ha sido reconocida como un grave problema que trae consigo el adelgazamiento de éstas y, por consiguiente, la falla de los equipos. En la última década se han incrementado las investigaciones que involucran recubrimientos protectores que ayudan de alguna manera a prolongar la vida útil de estos equipos. Esta investigación determinó el comportamiento de los recubrimientos NiCrAlY y NiCrFeNbMoTiAl depositados por proyección térmica asistida por plasma (APS sobre la aleación SA213 – T22 (2¼Cr – 1Mo, en un ambiente corrosivo de 80%V2O5–20%K2SO4 a 800°C. Los valores de la cinética de corrosión fueron determinados mediante resistencia a la polarización lineal (RPL y espectroscopia de impedancia electroquímica (EIE. Los resultados obtenidos muestran una menor cinética de corrosión en el recubrimiento NiCrFeNbMoTiAl que la presentada por el recubrimiento NiCrAlY, corroborado por Microscopia Electrónica de Barrido (MEB.

  17. Las pedagogías críticas: un lenguaje de la posibilidad para la universidad y sus maestros

    Directory of Open Access Journals (Sweden)

    Piedad Ramírez-Pardo

    2012-01-01

    Full Text Available El ensayo destaca los aportes de las pedagogías críticas para repensar el papel de la universidad y sus maestros en la sociedad. Reivindica la autonomía, la crítica, la libertad académica y la recuperación del maestro como intelectual transformativo, con capacidad para pensar la sociedad y construir un discurso que conjugue el lenguaje de la crítica con el de la posibilidad; maestros que se perciban a sí mismos con capacidad y opciones para enfrentar constructivamente la complejidad del mundo social y potenciar desde su rol, con sus estudiantes la transformación del orden establecido.

  18. Uptake studies of environmentally hazardous {sup 51}Cr in Mung beans

    Energy Technology Data Exchange (ETDEWEB)

    Banerjee, Anupam [Department of Botany, University of Calcutta, 35, Ballygunge Circular Road, Kolkata 700019 (India); Nayak, Dalia [Chemical Sciences Division, Saha Institute of Nuclear Physics, 1/AF Bidhannagar, Kolkata 700064 (India); Chakrabortty, Dipanwita [Sikkim Manipal University, A 15, Paryavaran Complex, New Delhi 110030 (India); Lahiri, Susanta [Chemical Sciences Division, Saha Institute of Nuclear Physics, 1/AF Bidhannagar, Kolkata 700064 (India)], E-mail: susanta.lahiri@saha.ac.in

    2008-01-15

    Attempt has been made to study the accumulation behaviour of a common plant, Mung bean (Vigna radiata) towards Cr(III) and Cr(VI) to have an insight on the migration and bio-magnification of Cr. For this purpose healthy germinated Mung bean seeds were sown in the sand in the presence of Hoagland's nutrient solution containing measured amount of K{sub 2}{sup 51}Cr{sub 2}O{sub 7} and {sup 51}Cr(NO{sub 3}){sub 3}.9H{sub 2}O. Growth rate was also studied in the presence and absence of phosphate salts in the medium. It has been found that the transfer of chromium from soil to plant is significantly low (maximum 5% for both Cr(III) and Cr(VI)). Maximum accumulation of Cr occurs in the root with respect to the total chromium accumulation by the plant. Other parts of the Mung bean plant, e.g. cotyledons, shoot and leaves, show negligible accumulation. Therefore, the chance of direct intake of Cr through food as well as through the grazing animals to human body is less. - The chance of bio-magnification of Cr(III) or Cr(VI) to human body via direct or indirect intake of Mung bean is negligible.

  19. A further study of the (CR-LR) difference technique for retrospective radon exposure assessment

    International Nuclear Information System (INIS)

    Nikezic, D.; Yip, C.W.Y.; Leung, S.Y.Y.; Leung, J.K.C.; Yu, K.N.

    2006-01-01

    The (CR-LR) difference technique, based on the CR-39 and LR 115 detectors, for the determination of implanted 210 Po in glass after deposition of short-lived radon progeny, was analyzed in details in this paper. The sensitivities of both detectors were calculated using the Monte Carlo method with V functions particularly derived in our previous works for the detectors used in the present experiments. The dependency of the sensitivity ratio on the removed layer of both detectors was determined and verified experimentally. The simulated sensitivity ratios correlate well with the experimental ones. A major finding of the present work is that the sensitivity ratio between the CR-39 and LR 115 detectors depends only weakly on the ratio between the 238 U and 232 Th concentrations in the glass samples. This is crucial for the application of the (CR-LR) difference technique for retrospective radon exposure assessments, since measurements of the 238 U and 232 Th concentrations in the relatively small real-life glass samples will make the retrospective radon exposure assessments impractical

  20. Preliminary study on 2-dimensional distributions of 10B reaction rate in a water phantom with boron-doped CR-39 for 7Li(p, n)7Be neutrons by 1.95 MeV protons

    International Nuclear Information System (INIS)

    Hasegawa, Y.; Tanaka, K.; Tsuruta, T.

    2000-01-01

    In an Accelerator-based neutron irradiation field using 7 Li(p, n) 7 Be neutrons by 1.95 MeV protons, the distributions of 10 B reaction rates and thermal neutron fluence in a water phantom were measured using Boron-doped CR-39 and Au activation analysis, respectively. Comparing the results of the measurements, we discussed the validity of the evaluation method of 10 B reaction rate using thermal neutron fluence. (author)

  1. Zwitterion-functionalized polymer microspheres as a sorbent for solid phase extraction of trace levels of V(V), Cr(III), As(III), Sn(IV), Sb(III) and Hg(II) prior to their determination by ICP-MS.

    Science.gov (United States)

    Jia, Xiaoyu; Gong, Dirong; Zhao, Junyi; Ren, Hongyun; Wang, Jiani; Zhang, Xian

    2018-03-19

    This paper describes the preparation of zwitterion-functionalized polymer microspheres (ZPMs) and their application to simultaneous enrichment of V(V), Cr(III), As(III), Sn(IV), Sb(III) and Hg(II) from environmental water samples. The ZPMs were prepared by emulsion copolymerization of ethyl methacrylate, 2-diethylaminoethyl methacrylate and triethylene glycol dimethyl acrylate followed by modification with 1,3-propanesultone. The components were analyzed by elemental analyses as well as Fourier transform infrared spectroscopy, and the structures were characterized by scanning electron microscopy and transmission electron microscopy. The ZPMs were packed into a mini-column for on-line solid-phase extraction (SPE) of the above metal ions. Following extraction with 40 mM NH 4 NO 3 and 0.5 M HNO 3 solution, the ions were quantified by ICP-MS. Under the optimized conditions, the enrichment factors (from a 40 mL sample) are up to 60 for the ions V(V), As(III), Sb(III) and Hg(II), and 55 for Cr(III) and Sn(IV). The detection limits are 1.2, 3.4, 1.0, 3.7, 2.1 and 1.6 ng L -1 for V(V), Cr(III), As(III), Sn(IV), Sb(III) and Hg(II), respectively, and the relative standard deviations (RSDs) are below 5.2%. The feasibility and accuracy of the method were validated by successfully analyzing six certified reference materials as well as lake, well and river waters. Graphical abstract Zwitterion-functionalized polymer microspheres (ZPMs) were prepared and packed into a mini-column for on-line solid-phase extraction (SPE) via pump 1. Then V(V), Cr(III), As(III), Sn(IV), Sb(III) and Hg(II) ions in environmental waters were eluted and submitted to ICP-MS via pump 2.

  2. Proyecto de factibilidad para la creación de una institución financiera de crédito prendarío, en la libertad-provincia de Santa Elena

    OpenAIRE

    Abril Briones, Ruben Dario; Estrada Guzman, Jairo Alfredo; Romero Montoya, Maria Elena

    2009-01-01

    El presente documento pretende justificar, económica y financieramente, la creación de una Institución Financiera de Crédito Prendario en La Libertad-Provincia de Santa Elena. Este proyecto muestra una alternativa de conceder financiamiento a través de créditos prendarios, además de desarrollar un mecanismo para facilitar los créditos, ofrecerá la debida protección de preservar la autenticidad y seguridad de los activos que garantizan los créditos prendarios, e incentivar una cultura de aper...

  3. A new method for studying the transport of radon and thoron in various building materials using CR-39 and LR-115 solid state nuclear track detectors

    International Nuclear Information System (INIS)

    Misdaq, M.A.; Ktata, A.; Bakhchi, A.

    2000-01-01

    Radon ( 222 Rn) and thoron ( 220 Rn) α-activities per unit volume were measured inside and outside different building materials by using two types of solid state nuclear track detectors (SSNTD) (CR-39 and LR-115 type II). In addition, the radon and thoron emanation coefficients of the studied materials were evaluated. Based on these data, the transport of radon and thoron across parallelepipedic blocks of the building materials could be investigated and radon and thoron global α-activities per unit volume outside different building material blocks were determined. Moreover, the diffusion length and the effective diffusion coefficient of radon in the building materials were evaluated and the total alpha activity due to radon in the atmospheres of different rooms consisting of different building materials was studied

  4. Study of Indoor Radon /Thoron And Its Hazard Inside Kindergartens In Iraqi Kurdistan Using CR39 Nuclear Track Detectors

    International Nuclear Information System (INIS)

    Ismail, A.H.

    2007-01-01

    Indoor radon /thoron levels with potential alpha energy concentration PAEC), effective dose (H E ) and equilibrium factor (F) were measured using closed and open-can technique, containing CR-39 nuclear track detector. Measurements were carried during summer season inside different Kindergartens in three main regions (Erbil, Duhok and Sullimaniye) in Iraqi Kurdistan. We found that the radon and thoron densities range from (11 to 33 track.cm -2 .d -1 ) for radon and (8 to 29 track.cm -2 .d -1 ) for thoron, with the average radon concentration (96.81 26.939Bq/m 3 ) While an average (PAEC) and (H E ) was (7.68±2.298 mWL) , (2.306± 0.689 mSv/Y) respectively. On the other hands the average equilibrium factor was (0.291±0.01). Consequently, we believe that our results were done when we comparing them with the action levels were recommended by (lCRP 66). The results obtained indicate that various locations have different values of radon/thoron concentration. The differences can be ascribed to variations in grades of uranium at different locations and to some environmental factors such as ventilation, particle concentration, and the deposition of the progeny on surfaces or on the atmospheric aerosol

  5. Selective transport of Fe(III) using ionic imprinted polymer (IIP) membrane particle

    Science.gov (United States)

    Djunaidi, Muhammad Cholid; Jumina, Siswanta, Dwi; Ulbricht, Mathias

    2015-12-01

    The membrane particles was prepared from polyvinyl alcohol (PVA) and polymer IIP with weight ratios of 1: 2 and 1: 1 using different adsorbent templates and casting thickness. The permeability of membrane towards Fe(III) and also mecanism of transport were studied. The selectivity of the membrane for Fe(III) was studied by performing adsorption experiments also with Cr(III) separately. In this study, the preparation of Ionic Imprinted Polymer (IIP) membrane particles for selective transport of Fe (III) had been done using polyeugenol as functional polymer. Polyeugenol was then imprinted with Fe (III) and then crosslinked with PEGDE under alkaline condition to produce polyeugenol-Fe-PEGDE polymer aggregates. The agrregates was then crushed and sieved using mesh size of 80 and the powder was then used to prepare the membrane particles by mixing it with PVA (Mr 125,000) solution in 1-Methyl-2-pyrrolidone (NMP) solvent. The membrane was obtained after casting at a speed of 25 m/s and soaking in NaOH solution overnight. The membrane sheet was then cut and Fe(III) was removed by acid to produce IIP membrane particles. Analysis of the membrane and its constituent was done by XRD, SEM and size selectivity test. Experimental results showed the transport of Fe(III) was faster with the decrease of membrane thickness, while the higher concentration of template ion correlates with higher Fe(III) being transported. However, the transport of Fe(III) was slower for higher concentration of PVA in the membrane. IImparticles works through retarded permeation mechanism, where Fe(III) was bind to the active side of IIP. The active side of IIP membrane was dominated by the -OH groups. The selectivity of all IIP membranes was confirmed as they were all unable to transport Cr (III), while NIP (Non-imprinted Polymer) membrane was able transport Cr (III).

  6. Association of MICA gene polymorphisms with liver fibrosis in schistosomiasis patients in the Dongting Lake region

    Energy Technology Data Exchange (ETDEWEB)

    Gong, Zheng; Luo, Qi-Zhi; Lin, Lin [Department of Immunology, College of Basic Medical Sciences, Central South University, Changsha, Hunan Province (China); Su, Yu-Ping; Peng, Hai-Bo [Central Blood Bank in Yueyang, Yueyang, Hunan Province (China); Du, Kun; Yu, Ping [Department of Immunology, College of Basic Medical Sciences, Central South University, Changsha, Hunan Province (China); Wang, Shi-Ping [Key Laboratory of Schistosomiasis in Hunan, Department of Parasitology, College of Basic Medical Sciences, Central South University, Changsha, Hunan Province (China)

    2012-03-02

    Major histocompatibility complex class I chain-related A (MICA) is a highly polymorphic gene located within the MHC class I region of the human genome. Expressed as a cell surface glycoprotein, MICA modulates immune surveillance by binding to its cognate receptor on natural killer cells, NKG2D, and its genetic polymorphisms have been recently associated with susceptibility to some infectious diseases. We determined whether MICA polymorphisms were associated with the high rate of Schistosoma parasitic worm infection or severity of disease outcome in the Dongting Lake region of Hunan Province, China. Polymerase chain reaction-sequence specific priming (PCR-SSP) and sequencing-based typing (SBT) were applied for high-resolution allele typing of schistosomiasis cases (N = 103, age range = 36.2-80.5 years, 64 males and 39 females) and healthy controls (N = 141, age range = 28.6-73.3 years, 73 males and 68 females). Fourteen MICA alleles and five short-tandem repeat (STR) alleles were identified among the two populations. Three (MICA*012:01/02, MICA*017 and MICA*027) showed a higher frequency in healthy controls than in schistosomiasis patients, but the difference was not significantly correlated with susceptibility to S. japonicum infection (Pc > 0.05). In contrast, higher MICA*A5 allele frequency was significantly correlated with advanced liver fibrosis (Pc < 0.05). Furthermore, the distribution profile of MICA alleles in this Hunan Han population was significantly different from those published for Korean, Thai, American-Caucasian, and Afro-American populations (P < 0.01), but similar to other Han populations within China (P > 0.05). This study provides the initial evidence that MICA genetic polymorphisms may underlie the severity of liver fibrosis occurring in schistosomiasis patients from the Dongting Lake region.

  7. Association of MICA gene polymorphisms with liver fibrosis in schistosomiasis patients in the Dongting Lake region

    International Nuclear Information System (INIS)

    Gong, Zheng; Luo, Qi-Zhi; Lin, Lin; Su, Yu-Ping; Peng, Hai-Bo; Du, Kun; Yu, Ping; Wang, Shi-Ping

    2012-01-01

    Major histocompatibility complex class I chain-related A (MICA) is a highly polymorphic gene located within the MHC class I region of the human genome. Expressed as a cell surface glycoprotein, MICA modulates immune surveillance by binding to its cognate receptor on natural killer cells, NKG2D, and its genetic polymorphisms have been recently associated with susceptibility to some infectious diseases. We determined whether MICA polymorphisms were associated with the high rate of Schistosoma parasitic worm infection or severity of disease outcome in the Dongting Lake region of Hunan Province, China. Polymerase chain reaction-sequence specific priming (PCR-SSP) and sequencing-based typing (SBT) were applied for high-resolution allele typing of schistosomiasis cases (N = 103, age range = 36.2-80.5 years, 64 males and 39 females) and healthy controls (N = 141, age range = 28.6-73.3 years, 73 males and 68 females). Fourteen MICA alleles and five short-tandem repeat (STR) alleles were identified among the two populations. Three (MICA*012:01/02, MICA*017 and MICA*027) showed a higher frequency in healthy controls than in schistosomiasis patients, but the difference was not significantly correlated with susceptibility to S. japonicum infection (Pc > 0.05). In contrast, higher MICA*A5 allele frequency was significantly correlated with advanced liver fibrosis (Pc < 0.05). Furthermore, the distribution profile of MICA alleles in this Hunan Han population was significantly different from those published for Korean, Thai, American-Caucasian, and Afro-American populations (P < 0.01), but similar to other Han populations within China (P > 0.05). This study provides the initial evidence that MICA genetic polymorphisms may underlie the severity of liver fibrosis occurring in schistosomiasis patients from the Dongting Lake region

  8. EFFICIENT POLYMER PHOTOVOLTAIC DEVICES BASED ON POLYMER D-A BLENDS

    Institute of Scientific and Technical Information of China (English)

    Xian-yu Deng; Li-ping Zheng; Yue-qi Mo; Gang Yu; Wei Yang; Wen-hua Weng; Yong Cao

    2001-01-01

    Recent work demonstrated that efficient solar-energy conversion could be achieved in polymer photovoltaic cells (PVCs) based on interpenetrating bi-continuous networks[1,2]. In this paper we present a comprehensive study on improving energy conversion efficiencies of PVCs based on composite films of MEHPPV and fullerene derivatives. Carrier collection efficiency of ca. 30% el/ph and energy conversion efficiency of 3.9% were achieved at 500 nm. At reverse bias of 15 V, the photosensitivity reached 0.8 A/W, corresponding to a quantum efficiency over 100% el/ph. These results suggest that high efficiency photoelectric conversion can be achieved in polymer devices with M-P-M structure. These devices are promising for practical applications such as plastic solar cells and plastic photodetectors.

  9. Two novel penetrating coordination polymers based on flexible S-containing dicarboxylate acid with sensing properties towards Fe3+ and Cr2O72- ions

    Science.gov (United States)

    Chen, Zhiwei; Mi, Xiuna; Wang, Suna; Lu, Jing; Li, Yunwu; Li, Dacheng; Dou, Jianmin

    2018-05-01

    Two new coordination polymers (CPs), namely, {[Zn(L)(bpp)]·DMF}n (1) and {[Zn(L)(bpe)]·DMF}n (2) (L = 2,2'-[benzene-1,3-diylbis(methanediylsulfanediyl)]dibenzoic acid, bpp= 1,3-bis(4-pyridyl)propane, bpe = 1,2-Bis(4-pyridyl)ethylene, DMF = N,N-Dimethylformamide), have been solvothermally synthesized and fully characterized. Complex 1 displays a 2D→2D three-fold"false" interpenetrating structure while complex 2 possesses a novel 3-D 4-connected structure with fascinating self-penetrating moieties. The luminescence studies reveal that these complexes exhibited excellent selectivity for Fe3+ and Cr2O72- ions in DMF. The sensing mechanism was investigated through PXRD, XPS , EDS mapping measurements, and discussed in details.

  10. Las polémicas inaugurales de la transición a la democracia: los casos argentino y paraguayo

    Directory of Open Access Journals (Sweden)

    Carla Daniela Benisz

    2017-01-01

    Full Text Available Tras la caída de las dictaduras del Cono Sur, el cambio político generó también cambios de paradigmas estéticos y éticos en el campo intelectual, que se expresaron en polémicas en distintos países de la región. Los casos, por lo general, han sido estudiados individualmente para cada país, pero las similitudes justifican un abordaje en conjunto. Este artículo presenta, como primera instancia, un estudio comparado de los casos argentino y paraguayo, con especial énfasis en este último, puesto que ha sido menos trabajado por la crítica literaria latinoamericana. De estos casos, a su vez, se enfoca en dos cruces polémicos concretos: por un lado, una famosa polémica entre Julio Cortázar y Liliana Heker y, por otro, las polémicas de Augusto Roa Bastos con Carlos Villagra Marsal y Guido Rodríguez-Alcalá.

  11. Dynamics of polymers

    Energy Technology Data Exchange (ETDEWEB)

    Buchenau, U [Forschungszentrum Juelich GmbH (Germany). Inst. fuer Energieverfahrenstechnik

    1996-11-01

    Neutron scattering from amorphous polymers allows to switch from incoherent to coherent scattering in the same substance. The power of the tool for the study of the picosecond dynamics of disordered matter is illustrated for polybutadiene, polycarbonate and polystyrene. The results suggest a mixture of sound waves and localized modes, strongly interacting with each other, in the picosecond range. (author) 8 figs., tabs., 39 refs.

  12. Orçamento público no Brasil: Um estudo dos créditos adicionais

    Directory of Open Access Journals (Sweden)

    Cinara Maria Carneiro Rocha

    2009-10-01

    Full Text Available Orçamento público é tema fundamental para compreensão das políticas públicas em qualquer país. O assunto é multidisciplinar: ciências econômicas, contábeis, administrativas e poíticas integram-se e complementam-se para compreensão do complexo universo orçamentário. Dentre as várias possibilidades de estudo sobre o tema orçamento público, este artigo está direcionado para o estudo de créditos adicionais - esses mecanismos que alteram, duranto o ano, o orçamento inicial aprovado no Congresso Nacional. Portanto, o primeiro objetivo da pesquisa é efetuar o tratamento dos dados relativos aos créditos adicionais e realizar análise de seu montante, além de procurar estabelecer um padrão de comportamento para autorizações de abertura de créditos adicionais para o período selecionado. O segundo objetivo é procurar, na teoria explicação para abertura dos créditos adicionais.

  13. Niveles de linfocitos T en pacientes portadores crónicos del virus de la hepatitis viral B en una zona hiperendémica del Perú

    Directory of Open Access Journals (Sweden)

    Saúl Chuchón M

    2005-04-01

    Full Text Available Objetivos: Determinar los niveles de linfocitos CD3, CD4, CD8 y coeficiente CD4/CD8 en portadores del virus de la hepatitis B (VHB de una zona hiperendémica del Perú (Huanta, departamento Ayacucho. Materiales y métodos: Estudio comparativo que incluyó tres grupos, pareados en función a la edad (¡Ü20 ó 20 años y sexo, a una razón aproximadamente de 1:1. Se incluyeron 114 personas, en los siguientes grupos: 30 portadores crónicos (casos, 44 pacientes con antecedente de infección (no portador o control y 40 individuos sin contacto previo con el VHB (sanos. De cada individuo, previo consentimiento informado, se obtuvieron dos muestras de sangre en un lapso de 30 a 45 días con la finalidad de caracterizar los grupos y realizar las pruebas de interés. Estas pruebas fueron: ELISA para HBsAg, anticore para anti HBc IgM y anti HBc IgG, y la técnica de diferenciación celular por citometría de flujo para la valoración de subpoblaciones de linfocitos T CD3+, CD4+ y CD8+. Resultados: Se encontró valores disminuidos del número de linfocitos T CD4/mm 3 en los portadores cróni cos de HBsAg (casos, respecto a los otros grupos (p = 0,017; en tanto que para los valores de linfocitos T CD3, T CD8 y coeficiente CD4/CD8 no se encontraron diferencias entre grupos. Asimismo, mediante ANOVA se halló diferencias entre los grupos de edad (mayor y menor de 20 años de los casos (p = 0,033, característica no observada en los otros grupos. Conclusiones: Se evidenció niveles menores de linfocitos T CD4/mm 3 en l os portadores cróni cos del VHB rel aci ón a l os otros grupos. Se sugiere realizar mayores estudios de inmunidad celular en la infección del VHB, buscando evaluar poblaciones celulares específicas que puedan emplearse como posibles marcadores de la evolución de la enfermedad.

  14. Emociones Negativas en Pacientes con Lumbalgia Crónica

    OpenAIRE

    M.ª Magdalena Truyols Taberner; M.ª Magdalena Medinas Amorós; Javier Perez Pareja; Alfonso Palmer Pol; Albert Sesé Abad

    2010-01-01

    El objetivo ha sido evaluar la ansiedad, depresión e ira en pacientes con dolor lumbar crónico y de un grupo control. Materiales y Método: la muestra incluyó n=54 pacientes y n=51 controles (15 hombres y 39 mujeres) con una media de edad de 49.20 años. Todos fueron evaluados mediante Inventario de Depresión de Beck, el Inventario de Situaciones y Respuestas de ansiedad y el Inventario de Expresión de Ira Estado-Rasgo. Los resultados muestran que los pacientes con lumbalgia crónica obtienen ni...

  15. Periodontitis crónica: Una visión desde la proteómica

    Directory of Open Access Journals (Sweden)

    Miguel Simancas Pallares

    2013-10-01

    Full Text Available  Resumen La periodontitis resulta en un daño tisular complejo a las estructuras de soporte dentario debido al efecto de la respuesta inmune. Sin embargo, la naturaleza de los componentes de éste proceso son interés de muchos investigadores ya que se determinaron a través de estudios experimentales algunas moléculas de carácter proteínico que activan y/o regulan otras sustancias ó células para el desarrollo de la lesión. El objetivo de ésta revisión de literatura es conducir un análisis crítico de la evidencia disponible sobre las proteínas expresadas durante la periodontitis crónica. Se identificaron las publicaciones más relevantes a través de una búsqueda en bases de datos electrónicas como MEDLINE, EBSCO-HOST y “The Cochrane Database of Systematic Reviews”. Para ser incluídos en la revisión, los estudios debieron definir la proteína investigada, en pacientes con periodontitis crónica. De los 1210 artículos obtenidos en la fase inicial de la revisión, sólo 175 estaban disponibles en texto completo y de éstos sólo cumplieron los requisitos de inclusión 25 artículos, los cuales fueron confrontados, analizados y discutidos posteriormente. La evidencia disponible demuestra que las proteínas juegan un papel importante en la transducción de señales y que utilizan diversas vías para activar compuestos químicos contribuyendo al desarrollo de lesiones periodontales crónicas. (DUAZARY 2010, 106 - 116AbstractPeriodontitis is a complex tissue damage to the supporting structures of teeth due to the effect of the immune response. However, the components nature of the process are of interest to many researchers and were determined through experimental studies of some molecules that activate a protein and / or regulating other substances or cells for the development of the lesion. The aim of this literature review is to conduct a critical analysis of available evidence on the expressed proteins in chronic

  16. 'Scan GFR' as an alternative to 51Cr-EDTA clearance

    International Nuclear Information System (INIS)

    Osman, E.A.; Clarke, M.B.; Barrett, J.J.; Parsons, V.; Dulwich Hospital, London

    1989-01-01

    In this report 39 patients had their GFR assessed by 51 Cr-EDTA in a single shot-multiple sampling technique and also by measuring the quantitative renal uptake of 99m Tc-DTPA during a standard renal imaging test. The results showed a correlation coefficient of 0.96 between the two techniques. By using linear regression analysis the GFR was derived from the % renal uptake of DTPA in a further series of 24 patients in whom the 51 Cr-EDTA method was also employed. The two methods were compared and showed a correlation coefficient of 0.94 with a mean GFR difference of 7 ± 4.5 ml/min over a 51 Cr-EDTA range of 38-150 ml/min. (orig.) [de

  17. Cinética e equilíbrio de adsorção dos oxiânions Cr (VI, Mo (VI e Se (VI pelo sal de amônio quaternário de quitosana Kinetics and equilibrium of adsorption of oxyanions Cr (VI, Mo (VI and Se (VI by quaternary ammonium chitosan salt

    Directory of Open Access Journals (Sweden)

    Viviane A. Spinelli

    2005-07-01

    Full Text Available O sal quaternário de quitosana foi sintetizado com cloreto de glicidil trimetil amônio. A modificação química foi caracterizada por espectrometria no IV, RMN de 13C e ¹H, e mmol/g de grupos quaternários presentes na matriz polimérica por condutimetria. A remoção de Cr (VI, Mo (VI e Se (VI, em meio aquoso, foi investigada em processo de batelada. A adsorção mostrou ser dependente do pH para o Cr (VI e Se (VI, com um pH ótimo de adsorção, entre 4,0 a 6,0. Para o Mo (VI a adsorção manteve-se quase constante no intervalo de pH entre 4,0 e 11,5. O modelo de isoterma de Langmuir descreveu melhor os dados de equilíbrio na faixa de concentração investigada. No presente estudo, um grama do sal quaternário de quitosana reticulado com glutaraldeído adsorveu 68,3 mg de Cr, 63,4 mg de Mo e 90,0 mg de Se. A velocidade de adsorção, no processo, segue a equação cinética de pseudo segunda-ordem, sendo que o equilíbrio para os três íons foi alcançado próximo aos 200 minutos. A análise dispersiva de raios-X para o Cr (VI mostrou que o principal mecanismo de adsorção é a troca iônica entre os íons Cl- da superfície do polímero pelos oxiânions. O trocador aniônico apresentou a seguinte ordem de seletividade: Cr (VI > Mo (VI > Se (VI.Quaternary chitosan salt was synthesized in the presence of glycidyl trimetyl ammonium chloride. The polymer was characterized by spectroscopic techniques: infrared, 13C and ¹H NMR, while the amount of quaternary ammonium groups was obtained by condutimetry. The removal of Cr (VI, Mo (VI and Se (VI from aqueous solutions was carried out in batch adsorption processes. The process seemed to be pH dependent for Cr (VI and Se (VI with an optimum pH ranging from 4.0 to 6.0; while for Mo (VI the adsorption remained almost constant within the range between 4.0 and 11.5. The Langmuir isotherm model provided the best fit of the equilibrium data over the whole concentration investigated. In the experiment

  18. Associação entre periodontite crônica e marcadores de risco para doença cardiovascular

    OpenAIRE

    André Luis Velloso Caúla Soares

    2009-01-01

    Pesquisas recentes têm demonstrado que a periodontite pode modificar a concentração sanguínea de uma série de tipos celulares e substâncias bioquímicas, que são considerados fatores de risco para doenças cardiovasculares. Este trabalho tem como objetivo avaliar a associação entre a periodontite crônica e marcadores de risco para doença cardiovascular. No Estudo I foram examinados 100 pacientes aparentemente saudáveis sistemicamente, sendo 66 portadores de periodontite crônica e 34 pacientes c...

  19. Calculation of depleted uranium concentration in dental fillings samples using the nuclear track detector CR-39

    International Nuclear Information System (INIS)

    Mahdi, K. H.; Subhi, A. T.; Tawfiq, N. F.

    2012-12-01

    The purpose of this study is to determine the concentration of depleted uranium in dental fillings samples, which were obtained some hospital and dental office, sale of materials deployed in Iraq. 8 samples were examined from two different fillings and lead-filling (amalgam) and composite filling (plastic). concentrations of depleted uranium were determined in these samples using a nuclear track detector CR-39 through the recording of the tracks left by of fragments of fission resulting from the reaction 2 38U (n, f). The samples are bombarded by neutrons emitted from the neutron source (2 41A m-Be) with flux of ( 10 5 n. cm- 2. s -1 ). The period of etching to show the track of fission fragments is 5 hours using NaOH solution with normalization (6.25N), and temperature (60 o C ). Concentration of depleted uranium were calculated by comparison with standard samples. The result that obtained showed that the value of the weighted average for concentration of uranium in the samples fillings (5.54± 1.05) ppm lead to thr filling (amalgam) and (5.33±0.6) ppm of the filling composite (plastic). The hazard- index, the absorbed dose and the effective dose for these concentration were determined. The obtained results of the effective dose for each of the surface of the bone and skin (as the areas most affected by this compensation industrial) is (0.56 mSv / y) for the batting lead (amalgam) and (0.54 mSv / y) for the filling composite (plastic). From the results of study it was that the highest rate is the effective dose to a specimen amalgam filling (0.68 mSv / y) which is less than the allowable limit for exposure of the general people set the World Health Organization (WHO), a (1 mSv / y). (Author)

  20. Response of CR-39 to 0.9-2.5 MeV protons for KOH and NaOH etching solutions

    Science.gov (United States)

    Bahrami, F.; Mianji, F.; Faghihi, R.; Taheri, M.; Ansarinejad, A.

    2016-03-01

    In some circumstances passive detecting methods are the only or preferable measuring approaches. For instance, defining particles' energy profile inside the objects being irradiated with heavy ions and measuring fluence of neutrons or heavy particles in space missions are the cases covered by these methods. In this paper the ability of polyallyl diglycol carbonate (PADC) track detector (commercially known as CR-39) for passive spectrometry of proton particles is studied. Furthermore, the effect of KOH and NaOH as commonly used chemical etching solutions on the response of the detector is investigated. The experiments were carried out with protons in the energy range of 0.94-2.5 MeV generated by a Van de Graaff accelerator. Then, the exposed track dosimeters were etched in the two aforementioned etchants through similar procedure with the same normality of 6.25 N and the same temperature of 85 °C. Formation of the tracks was precisely investigated and the track diameters were recorded following every etching step for each solution using a multistage etching process. The results showed that the proposed method can be efficiently used for the spectrometry of protons over a wider dynamic range and with a reasonable accuracy. Moreover, NaOH and KOH outperformed each other over different regions of the proton energy range. The detection efficiency of both etchants was approximately 100%.

  1. Temperature-induced phase separation and hydration in aqueous polymer solutions studied by NMR and IR spectroscopy: comparison of poly(N-vinylcaprolactam) and acrylamide-based polymers

    Czech Academy of Sciences Publication Activity Database

    Spěváček, Jiří; Dybal, Jiří

    2014-01-01

    Roč. 336, č. 1 (2014), s. 39-46 ISSN 1022-1360. [International IUPAC Conference on Polymer-Solvent Complexes and Intercalates /9./ - POLYSOLVAT-9. Kiev, 11.09.2012-14.09.2012] R&D Projects: GA ČR GA202/09/1281 Institutional support: RVO:61389013 Keywords : aqueous polymer solutions * FT-IR * NMR Subject RIV: CD - Macromolecular Chemistry

  2. Clarice Lispector y la crítica

    Directory of Open Access Journals (Sweden)

    Luciana Namorato

    2012-05-01

    Full Text Available En una entrevista publicada en julio de 2011, Antonio Candido observa que el crítico de hoy en día se arriesga mucho menos que en su época. En sus palabras: “Hoy la crítica académica no corre riesgo alguno, es una actividad extremadamente segura. Los jóvenes escriben tesis sobre Machado de Assis, Jorge Amado, José Lins do Rego, Clarice Lispector. Ahora, la persona no escoge un libro de un autor contemporáneo y dice ‘éste es bueno, éste es malo’. Eso se acabó” (Candido, 2011: 2. A sus noventa y dos años, Candido recuerda la suerte de haber trabajado en un tiempo de esplendor en la literatura brasileña. Crítico titular del periódico Folha da Manhã de São Paulo en la década de los 40, Candido publicaba semanalmente un artículo sobre las novedades literarias de la época. Las “novedades” de su época eran nada menos que obras de Carlos Drummond de Andrade, João Cabral de Melo Neto, Jorge Amado, José Lins do Rego y Graciliano Ramos, hoy consideradas figuras canónicas de las letras brasileñas. Candido recuerda, en esta misma entrevista, que en 1943 recibió un libro titulado Cerca del corazón salvaje, la primera novela de Clarice Lispector.

  3. White Polymer Light-Emitting Diodes Based on Exciplex Electroluminescence from Polymer Blends and a Single Polymer.

    Science.gov (United States)

    Liang, Junfei; Zhao, Sen; Jiang, Xiao-Fang; Guo, Ting; Yip, Hin-Lap; Ying, Lei; Huang, Fei; Yang, Wei; Cao, Yong

    2016-03-09

    In this Article, we designed and synthesized a series of polyfluorene derivatives, which consist of the electron-rich 4,4'-(9-alkyl-carbazole-3,6-diyl)bis(N,N-diphenylaniline) (TPA-Cz) in the side chain and the electron-deficient dibenzothiophene-5,5-dioxide (SO) unit in the main chain. The resulting copolymer PF-T25 that did not comprise the SO unit exhibited blue light-emission with the Commission Internationale de L'Eclairage coordinates of (0.16, 0.10). However, by physically blending PF-T25 with a blue light-emitting SO-based oligomer, a novel low-energy emission correlated to exciplex emerged due to the appropriate energy level alignment of TPA-Cz and the SO-based oligomers, which showed extended exciton lifetime as confirmed by time-resolved photoluminescent spectroscopy. The low-energy emission was also identified in copolymers consisting of SO unit in the main chain, which can effectively compensate for the high-energy emission to produce binary white light-emission. Polymer light-emitting diodes based on the exciplex-type single greenish-white polymer exhibit the peak luminous efficiency of 2.34 cd A(-1) and the maximum brightness of 12 410 cd m(-2), with Commission Internationale de L'Eclairage color coordinates (0.27, 0.39). The device based on such polymer showed much better electroluminescent stability than those based on blending films. These observations indicated that developing a single polymer with the generated exciplex emission can be a novel and effective molecular design strategy toward highly stable and efficient white polymer light-emitting diodes.

  4. Improving geotechnical properties of clayey soil using polymer material

    Directory of Open Access Journals (Sweden)

    Karim Hussein

    2018-01-01

    Full Text Available This study illustrates the application of polymer material for clayey soil stabilization. The article will focus on studying the strength behavior of the clayey soils reinforced with homogenously polymer fiber. In the current research, “polypropylene” was selected as polymer material to reinforce the natural clay soil. This polymer fiber was added to the clayey soil with four different percentages of (0, 1.5, 3, and 5% by weight of soil. Various tests with different polymer contents were performed to study the effect of using such a polymer as a stabilizing agent on geotechnical properties of clay. As the fiber content increases, the optimum moisture content (OMC is increased while the specific gravity decreases. For Atterberg’s limits, the results indicated increasing liquid limit and plasticity index while decreasing plastic limit with increase in polymer content. The outcomes of the tests also reflected a considerable improvement in the unconfined compressive strength with noticeable improvement in the shear strength parameter (undrained shear strength, cu of the treated soils. The undrained shear strength obtained from treated soil with 5% polymer addition is more than three times that of the untreated soil. With an increase in polymer content, the consolidation parameters (Compression index Cc and recompression index Cr decreases. Finally, the benefit of the reinforcement is increased with increasing polymer fiber content.

  5. Processos co-evolutivos entre dança e crítica: de um contexto cearense a uma crítica contemporânea de dança

    OpenAIRE

    Arrais, Joubert de Albuquerque

    2013-01-01

    O presente estudo tem por objetivo apresentar uma outra moldura teórica e indisciplinar sobre o exercício da crítica especializada, com uma análise da dinâmica operativa da dança contemporânea em Fortaleza (CE), a partir do conceito evolutivo de "corrida armamentista", do cientista Richard Dawkins, e com o pressuposto de que a "dança é um sistema co-evolutivo", desenvolvido pela pesquisadora Fabiana Dultra Britto. O período escolhido inicia-se na segunda metade dos anos noventa...

  6. Dinámica de la producción porcina en México de 1980 a 2008

    Directory of Open Access Journals (Sweden)

    Encarnación Ernesto Bobadilla Soto

    2010-01-01

    Full Text Available El objetivo fue evaluar la dinámica de la producción porcina nacional e identificar los puntos críticos, los cambios y ajustes, de 1980 a 2008. Se analizó el país en su conjunto, las cinco regiones socio-económicas y los Estados que lo conforman. Los datos fueron obtenidos de SAGARPA, Banco de México y de la Secretaria de Economía, y se evaluaron indicadores de crecimiento, tendencia y precios reales. La política económica y financiera afectó la capacidad de pago de los productores. Los inventarios disminuyeron y modificó la dinámica del sector de forma negativa. La apertura comercial modificó negativamente la porcicultura mexicana, ya que la mayoría de los productos cárnicos y despojos comestibles de porcino importados, fueron introducidos al país con precios por debajo de los costos de producción mexicanos. La política de sacrificio favoreció únicamente a un sector. La producción de carne se desarrolló principalmente en los estados de Jalisco, Sonora, Guanajuato, Michoacán y los estados con mayor crecimiento fueron Yucatán, Puebla, Sonora, Guanajuato, con mayor decremento el Estado de México, Michoacán y Jalisco.

  7. Mica fission detectors

    International Nuclear Information System (INIS)

    Wong, C.; Anderson, J.D.; Hansen, L.; Lehn, A.V.; Williamson, M.A.

    1977-01-01

    The present development status of the mica fission detectors is summarized. It is concluded that the techniques have been refined and developed to a state such that the mica fission counters are a reliable and reproducible detector for fission events

  8. 40Ar/39Ar and K/Ar whole rock age constraints on the timing of regional deformation, South Coast of New South Wales, Lachlan Fold Belt, Southeastern Australia: problems and implications

    International Nuclear Information System (INIS)

    Phillips, D.; Fergusson, C.L.

    1999-01-01

    Full text: Subduction complex rocks are well exposed on the south coast of New South Wales around Batemans Bay. Farther south in the Narooma and Bermagui region, Offier et al (1998) have determined two 40 Ar/ 39 Ar ages of 450 ± 3 Ma and 445 ± 2 Ma. They argued that these ages constrain the timing of intense underplating-related deformation and we have undertaken farther work, from an area south of Batemans Bay, to test this suggestion. The 40 Ar/ 39 Ar method applied to fine-grained, low temperature metamorphic rocks, such as slates, is beset by the problem of recoil loss and/or redistribution of 39 Ar during the irradiation process. Another problem is the difficulty of distinguishing between the contributions to 40 Ar/ 39 Ar spectra from illite/muscovite grown during the cleavage-producing deformation and detrital muscovite/illite. In the current study, four slate samples, with variable contents of detrital white mica, were analysed by both the K-Ar and 40 Ar/ 39 Ar step-heating methods. A separate of detrital white mica from one slate sample yields a plateau age of 500 ± 2 Ma. This result indicates that inheritance has not been eliminated by metamorphism as is commonly assumed and that the 40 Ar/ 39 Ar ages provide only a maximum estimate for the timing of deformation. 40 Ar/ 39 Ar analyses of state chips yield discordant, saddle-shaped age spectra, with minimum, within-saddle' ages of ca. 420 Ma. Two slate samples give identical 40 Ar/ 39 Ar integrated ages of 455 ± 2 Ma. One sample contains relatively abundant detrital bedding-parallel mica flakes that are locally oblique to the regional cleavage in the rock. The 40 Ar/ 39 Ar ages are some 20 Ma older than K-Ar ages for these same samples, suggesting that recoil loss of 39 Ar may also have affected these slates. Both recoil loss of 39 Ar and inherited white micas will yield elevated apparent ages, thus providing only maximum ages for the cleavage-producing deformation. Two other samples from slaty tectonic

  9. Biotermodin?mica en animales

    OpenAIRE

    Granados Moreno, Jairo Enrique

    2014-01-01

    El documento presenta como la termodin?mica es la ciencia que estudia las relaciones entre calor y las dem?s formas de transferencias de energ?a. Se explica que toda transformaci?n biofisicoqu?mica implica, generalmente, un cambio energ?tico. Se tratan los conceptos de temperatura, escalas de temperatura, calor, calor de combusti?n, postulados de la termodin?mica, entrop?a y energ?a libre metab?lica

  10. Enhanced Oil Recovery by a Horizontal Well Located Inside a Polymer Flood Pilot Récupération assistée des hydrocarbures par forage horizontal à l'intérieur d'un pilote d'injection de polymère

    Directory of Open Access Journals (Sweden)

    Foxonet F.

    2006-11-01

    Full Text Available Amongst the new technologies conceived to improve production from oil zones, horizontal drilling associated with an injection scheme appears to be highly promising. In this respect, well CR 163 H, drilling unconsolidated sand as the main objective, has been an interesting experience. Elf Aquitaine is now reputed for its knowledge and expertise in horizontal drilling and CR 163 H was its fifth but probably most difficult horizontal well. This time the target was a 7 m thick sand reservoir at a vertical depth of 580 m inside a polymer flood pilot. In this inverted seven spot configuration with one injector in the center and 6 producers at a distance of 400 m, a polymer solution was injected from 1977 to 1983, followed by water injection. The horizontal section of CR 163 H is located at the northern edge of the pilot at a distance of 350 m from the injector and roughly follows the curved shape of the expected oil bank. Its productivity index is about 7 times that of the average of the vertical surrounding wells. A sharp drop in the water-cut occurred in March 1988 until October 1988 and then leveled out to the same value as the nearby wells. This behaviour was clearly due to the oil bank generated by the polymer injection, making CR 163 H an efficient tool for what could be called Geometrically enhanced oil recovery . Parmi les nouvelles technologies étudiées pour améliorer la production des zones pétrolifères, le forage horizontal associé à un programme d'injection semble très prometteur. L'expérience du puits CR 163 H, foré dans une couche de grès non consolidé, est très intéressante à cet égard. Pour Elf Aquitaine, dont l'expertise en matière de forage horizontal est aujourd'hui reconnue, le puits CR 163 H a été la cinquième expérience dans ce domaine mais sans doute la plus difficile. Le forage visait un réservoir gréseux de 7 m d'épaisseur situé à 580 m de profondeur, dans un pilote d'injection de polymère. La

  11. Quantifying Cr(VI) Production and Export from Serpentine Soil of the California Coast Range.

    Science.gov (United States)

    McClain, Cynthia N; Fendorf, Scott; Webb, Samuel M; Maher, Kate

    2017-01-03

    Hexavalent chromium (Cr(VI)) is generated in serpentine soils and exported to surface and groundwaters at levels above health-based drinking water standards. Although Cr(VI) concentrations are elevated in serpentine soil pore water, few studies have reported field evidence documenting Cr(VI) production rates and fluxes that govern Cr(VI) transport from soil to water sources. We report Cr speciation (i) in four serpentine soil depth profiles derived from the California Coast Range serpentinite belt and (ii) in local surface waters. Within soils, we detected Cr(VI) in the same horizons where Cr(III)-minerals are colocated with biogenic Mn(III/IV)-oxides, suggesting Cr(VI) generation through oxidation by Mn-oxides. Water-extractable Cr(VI) concentrations increase with depth constituting a 7.8 to 12 kg/km 2 reservoir of Cr(VI) in soil. Here, Cr(VI) is produced at a rate of 0.3 to 4.8 kg Cr(VI)/km 2 /yr and subsequently flushed from soil during water infiltration, exporting 0.01 to 3.9 kg Cr(VI)/km 2 /yr at concentrations ranging from 25 to 172 μg/L. Although soil-derived Cr(VI) is leached from soil at concentrations exceeding 10 μg/L, due to reduction and dilution during transport to streams, Cr(VI) levels measured in local surface waters largely remain below California's drinking water limit.

  12. Pneumonite intersticial crónica

    Directory of Open Access Journals (Sweden)

    Rui Almeida

    2004-05-01

    Full Text Available RESUMO: A patologia pulmonar intersticial compreende um grupo de doenças crónicas caracterizadas por alterações das paredes alveolares e perda das unidades funcionais alveolocapilares. São doenças raras nas crianças, na sua maioria de causa desconhecida e revestindo-se habitualmente de uma elevada morbimortalidade, dada a pouca eficácia da terapêutica actualmente disponível.Os autores descrevem o caso clínico de uma criança de 3 anos, previamente saudável, que no contexto de uma infecção respiratória desenvolve um quadro de sibilância e insuficiência respiratória grave, na investigação do qual é diagnosticada uma pneumonite intersticial crónica. Foram tentadas diversas terapêuticas (corticoterapia sistémica, hidroxicloroquina, N-acetilcisteína sem melhoria evidente.REV PORT PNEUMOL 2004; X (3: 243-251 ABSTRACT: Interstitial lung disease includes a group of chronic diseases characterized by alterations in alveolar walls and loss of functional alveolar-capillary units. These are rare diseases in children, mostly with an unknown cause and associated with a high morbidity and mortality due to insufficient therapeutic effectiveness.The authors report a case of a previously healthy 3 years old child who presented with wheezing and severe respiratory insufficiency following a respiratory infection. The investigation performed led to the diagnosis of chronic interstitial pneumonitis. Several treatments have been tried (corticosteroids, hydroxychloroquine, N-acetylcysteine without any obvious improvement.REV PORT PNEUMOL 2004; X (3:243-251 Palavras-chave: pneumonite intersticial, sibilância, doença pulmonar crónica, crianças, Key-words: interstitial pneumonitis, wheezing, chronic pulmonary disease, children

  13. Studies on the effects of helium on the microstructural evolution of V-3.8Cr-3.9Ti

    Energy Technology Data Exchange (ETDEWEB)

    Doraiswamy, N.; Kestel, B.; Alexander, D.E. [Argonne National Labs., IL (United States)

    1997-04-01

    The favorable physical and mechanical properties of V-3.8Cr-3.9Ti (wt.%), when subjected to neutron irradiation, has lead to considerable attention being focused on it for use in fusion reactor structural applications. However, there is limited data on the effects of helium on physical and mechanical properties of this alloy. Understanding these effects are important since helium will be generated by direct {alpha}-injection or transmutation reactions in the fusion environment, typically at a rate of {approx}5 appm He/dpa. Helium has been shown to cause substantial embrittlement, even at room temperature in vanadium and its alloys. Recent simulations of the fusion environment using the Dynamic Helium Charging Experiments (DHCE) have also indicated that the mechanical properties of vanadium alloys are altered by the presence of helium in post irradiation tests performed at room temperature. While the strengths were lower, room temperature ductilities of the DHCE specimens were higher than those of non-DHCE specimens. These changes have been attributed to the formation of different types of hardening centers in these alloys due to He trapping. Independent thermal desorption experiments suggest that these hardening centers may be associated with helium-vacancy-X (where X = O, N, and C) complexes. These complexes are stable below 290{degrees}C and persist at room temperature. However, there has been no direct microstructural evidence correlating the complexes with irradiation effects. An examination of the irradiation induced microstructure in samples preimplanted with He to different levels would enable such a correlation.

  14. Generación y dinámica de electrones runaway en plasmas tokamak

    OpenAIRE

    Fernández Gómez, Isabel

    2016-01-01

    La dinámica y generación de electrones runaway en plasmas tokamak constituye el tema central de esta tesis. En un tokamak, el fenómeno runaway es el resultado de la existencia de un campo eléctrico en dirección toroidal. Aquellos electrones cuya velocidad excede un cierto valor crítico se aceleran de forma continua, ya que la e ciencia de las colisiones para disipar la energía ganada en el campo disminuye con la velocidad (∼ ⁻¹) . Se tiene entonces lo que se conoce como un electrón runaway. ...

  15. Arte popular y crítica a la modernidad

    Directory of Open Access Journals (Sweden)

    Orlando Morillo

    2016-01-01

    Full Text Available El arte popular, concebido como lenguaje, posibilita el descentramiento de los relatos modernos y pone en evidencia los vicios de la civilización a través de un posicionamiento ético-crítico que busca un horizonte de sentido humanizante para desterrar los excesos de la instrumentalidad positivista y cientifizante. Es mediante la incidencia del arte popular y su valoración simbólica que se pueden generar procesos de revisión histórica, para que junto al eclecticismo crítico, el nihilismo y la deconstrucción, se pueda arribar a una autonomía social e individual capaz de conformar una “utopía estética” que apunte a un “sentido orgánico de la vida”, a la interrelación armónica entre pensamiento, naturaleza y ser humano. Todo en beneficio de una subjetividad epistémica que dignifique al sujeto como centro, ante la arremetida de los excesos de la modernidad.

  16. Una evaluación crítica de la contabilidad ambiental empresarial

    Directory of Open Access Journals (Sweden)

    Fabián Leonardo Quinche Martín

    2008-01-01

    Full Text Available La discusión por la relación entre contabilidad y medio ambiente ha sido poco abordada en nuestro país. El presente artículo pretende profundizar en esta discusión que implica tener en cuenta el carácter social, institucional y disciplinar de la contabilidad. Por esta razón, es necesario abordar el papel del conocimiento y de las disciplinas económicas en la visión y tratamiento de la naturaleza. Se parte de una visión interdisciplinar y crítica de las disciplinas económicas, para llegar a la evaluación de lo que ha sido la contabilidad ambiental empresarial. Se concluye que ella ha llevado a la traducción de las tecnologías tradicionales de la contabilidad empresarial y a la legitimación de actividades no ambientalmente amigables a través del discurso y de la información producida

  17. Regimes de endividamento, fragilidade financeira e dinâmica da atividade produtiva

    OpenAIRE

    Meirelles, Antonio J. A.; Lima, Gilberto Tadeu

    2003-01-01

    Elabora-se um modelo pós-keynesiano de utilização e crescimento da capacidade produtiva, no qual a oferta de moeda de crédito é endógena e o endividamento das firmas é explicitamente modelado. A taxa de juros é determinada pela aplicação de um mark-up sobre a taxa básica fixada pela autoridade monetária. O mark-up bancário varia intertemporalmente em conseqüência de mudanças no nível de atividade econômica, medido pela utilização da capacidade produtiva. Por seu turno, o grau de endividamento...

  18. "La masonería en la literatura. Una panorámica general"

    Directory of Open Access Journals (Sweden)

    José Antonio Ferrer Benimeli

    2013-01-01

    Full Text Available ResumenEste ensayo esboza una panorámica general e internacional del binomio Literatura-masonería, estudiado porpaíses y con un cierto orden cronológico. En él se abordan aquellos literatos más conocidos que al mismotiempo fueron masones aunque no reflejen directamente su compromiso con la masonería en sus escritosliterarios. Los que sí manifiestan en sus obras el dualismo masónico-literario. Autores no masones que aluden ala masonería en sus obras y que incluso la elevan a categoría de protagonista. Y estudios críticos sobre dichosautores y sus obras.

  19. Monitoração hemodinâmica e da oxigenação tecidual minimamente invasiva em cães

    OpenAIRE

    Gehrcke, Martielo Ivan

    2014-01-01

    Devido à importância da monitoração hemodinâmica e da oxigenação tecidual na anestesiologia e em pacientes críticos, buscam-se métodos minimamente invasivos e acurados para monitoração do débito cardíaco e da oxigenação tecidual. Esta tese apresenta quatro estudos que visam a monitoração hemodinâmica e da oxigenação tecidual em cães. O primeiro, trata-se de uma revisão sobre os diferentes métodos para monitoração do débito cardíaco em cães, ressaltando a importância de se utilizar técnicas mi...

  20. Response of CR-39 to 0.9–2.5 MeV protons for KOH and NaOH etching solutions

    Energy Technology Data Exchange (ETDEWEB)

    Bahrami, F. [Department of Medical Radiation Engineering, Shiraz University, Shiraz (Iran, Islamic Republic of); Mianji, F., E-mail: fmianji@aeoi.org.ir [Nuclear Science & Technology Research Institute, Tehran (Iran, Islamic Republic of); Iran Nuclear Regulatory Authority, Tehran (Iran, Islamic Republic of); Faghihi, R. [Department of Medical Radiation Engineering, Shiraz University, Shiraz (Iran, Islamic Republic of); Taheri, M. [Iran Nuclear Regulatory Authority, Tehran (Iran, Islamic Republic of); Ansarinejad, A. [Nuclear Science & Technology Research Institute, Tehran (Iran, Islamic Republic of)

    2016-03-21

    In some circumstances passive detecting methods are the only or preferable measuring approaches. For instance, defining particles' energy profile inside the objects being irradiated with heavy ions and measuring fluence of neutrons or heavy particles in space missions are the cases covered by these methods. In this paper the ability of polyallyl diglycol carbonate (PADC) track detector (commercially known as CR-39) for passive spectrometry of proton particles is studied. Furthermore, the effect of KOH and NaOH as commonly used chemical etching solutions on the response of the detector is investigated. The experiments were carried out with protons in the energy range of 0.94–2.5 MeV generated by a Van de Graaff accelerator. Then, the exposed track dosimeters were etched in the two aforementioned etchants through similar procedure with the same normality of 6.25 N and the same temperature of 85 °C. Formation of the tracks was precisely investigated and the track diameters were recorded following every etching step for each solution using a multistage etching process. The results showed that the proposed method can be efficiently used for the spectrometry of protons over a wider dynamic range and with a reasonable accuracy. Moreover, NaOH and KOH outperformed each other over different regions of the proton energy range. The detection efficiency of both etchants was approximately 100%.

  1. Pesquisa e desenvolvimento em cerâmicas eletro-eletrônicas no IPEN

    Directory of Open Access Journals (Sweden)

    Muccillo R.

    1999-01-01

    Full Text Available O Grupo de Cerâmicas Eletro-eletrônicas do IPEN desenvolve trabalhos de pesquisa em materiais cerâmicos avançados para utilização em dispositivos sensores de espécies químicas e em células de combustíveis a eletrólitos sólidos. As principais áreas de atuação do grupo são em 1 síntese, processamento e caracterização elétrica de materiais cerâmicos, 2 estudo de correlação microestrutura-propriedades elétricas de materiais cerâmicos, 3 projeto, desenvolvimento, montagem e testes de sensores eletroquímicos de espécies químicas. Os principais materiais estudados são condutores iônicos (à base de ZrO2, ThO2 e outros, protônicos (à base de BaCeO3, varistores à base de SnO2, supercondutores cerâmicos de alta temperatura crítica (das famílias Y-Ba-Cu-O e Bi-Sr-Ca-Cu-O e compósitos de matriz cerâmica (dos tipos isolante em matriz condutora iônica e condutor iônico em matriz supercondutora. A infra-estrutura experimental dispõe de analisador de impedância, difratômetro de raios X, equipamento de análise térmica simultânea, fornos para sinterização e laboratório químico. O trabalho de pesquisa do Grupo é financiado por projetos FAPESP e PRONEX.

  2. La promoción del pensamiento crítico en el Aprendizaje Basado en Problemas (ABP. Un análisis a partir de los instrumentos de medición.

    Directory of Open Access Journals (Sweden)

    Guillem Antequera Gallego

    2011-11-01

    Full Text Available La literatura científica sobre el Aprendizaje Basado en Problemas (ABP ha dedicado una atención creciente a la cuestión del pensamiento crítico a lo largo de las dos últimas décadas. Los trabajos de investigación que se han llevado a cabo en los distintos contextos disciplinares de la educación superior presentan definiciones e instrumentos de medición del pensamiento crítico dispares. El presente artículo parte de dicha apreciación y trata de revisar sistemáticamente los mencionados trabajos con un doble objetivo: por un lado, esbozar una clasificación de los instrumentos de medición del pensamiento crítico de estudiantes de ABP y, por el otro, mostrar una panorámica de las evidencias hasta ahora obtenidas; todo ello con la finalidad de animar a profesores, estudiosos y autoridades académicas a seguir avanzando en esta línea de investigación.

  3. Measurement of concentrations of radon and its daughters in indoor atmosphere using CR-39 nuclear track detector

    International Nuclear Information System (INIS)

    Farid, S.M.

    1993-01-01

    This paper presents the results of the measurements of indoor 222 Rn and daughter levels in houses of different types located in different parts of Bangladesh. The passive time-integrated method of using a solid state nuclear track detector (CR-39) was employed for measuring both the 222 Rn gas concentration as well as the potential alpha energy exposure (PAEE) level from the short lived daughters of 222 Rn. The 222 Rn concentration from cup exposure and the PAEE from the bare exposure were obtained directly from the track density using calibration curves. A total of 275 exposures were made in the bare mode in 15 locations and 71 exposures in the cup mode in 6 locations. The geometric mean PAEE level obtained is 9.5 mWL with a geometric standard deviation of 1.9. The corresponding value for 222 Rn concentration are 61.3 Bq.M -3 and 2.4. The total data was collected over a period of one and a half year. The monthly variation of the geometric mean of PAEE is also shown. The annual effective dose equivalent has been estimated for each location by using the conversion factor of 9 mWv per WLM as obtained from ICRP-50. The average PAEE level obtained from the total data is below the intervention level as suggested by US EPA. However, the individual averages for each location show that in 8 out of 15 locations intervention may be considered and in others not intervention is called for. The 222 Rn concentrations at the seven locations are equal or less than the equilibrium equivalent 222 Rn concentration value as suggested by EPA. Attempts have also been made to see the variation in the PAEE levels according to different type of construction material used for the houses. (Author)

  4. 28 CFR 39.104-39.109 - [Reserved

    Science.gov (United States)

    2010-07-01

    ... 28 Judicial Administration 1 2010-07-01 2010-07-01 false [Reserved] 39.104-39.109 Section 39.104-39.109 Judicial Administration DEPARTMENT OF JUSTICE ENFORCEMENT OF NONDISCRIMINATION ON THE BASIS OF HANDICAP IN PROGRAMS OR ACTIVITIES CONDUCTED BY THE DEPARTMENT OF JUSTICE §§ 39.104-39.109 [Reserved] ...

  5. 28 CFR 39.141-39.148 - [Reserved

    Science.gov (United States)

    2010-07-01

    ... 28 Judicial Administration 1 2010-07-01 2010-07-01 false [Reserved] 39.141-39.148 Section 39.141-39.148 Judicial Administration DEPARTMENT OF JUSTICE ENFORCEMENT OF NONDISCRIMINATION ON THE BASIS OF HANDICAP IN PROGRAMS OR ACTIVITIES CONDUCTED BY THE DEPARTMENT OF JUSTICE §§ 39.141-39.148 [Reserved] ...

  6. 28 CFR 39.152-39.159 - [Reserved

    Science.gov (United States)

    2010-07-01

    ... 28 Judicial Administration 1 2010-07-01 2010-07-01 false [Reserved] 39.152-39.159 Section 39.152-39.159 Judicial Administration DEPARTMENT OF JUSTICE ENFORCEMENT OF NONDISCRIMINATION ON THE BASIS OF HANDICAP IN PROGRAMS OR ACTIVITIES CONDUCTED BY THE DEPARTMENT OF JUSTICE §§ 39.152-39.159 [Reserved] ...

  7. 28 CFR 39.131-39.139 - [Reserved

    Science.gov (United States)

    2010-07-01

    ... 28 Judicial Administration 1 2010-07-01 2010-07-01 false [Reserved] 39.131-39.139 Section 39.131-39.139 Judicial Administration DEPARTMENT OF JUSTICE ENFORCEMENT OF NONDISCRIMINATION ON THE BASIS OF HANDICAP IN PROGRAMS OR ACTIVITIES CONDUCTED BY THE DEPARTMENT OF JUSTICE §§ 39.131-39.139 [Reserved] ...

  8. 28 CFR 39.112-39.129 - [Reserved

    Science.gov (United States)

    2010-07-01

    ... 28 Judicial Administration 1 2010-07-01 2010-07-01 false [Reserved] 39.112-39.129 Section 39.112-39.129 Judicial Administration DEPARTMENT OF JUSTICE ENFORCEMENT OF NONDISCRIMINATION ON THE BASIS OF HANDICAP IN PROGRAMS OR ACTIVITIES CONDUCTED BY THE DEPARTMENT OF JUSTICE §§ 39.112-39.129 [Reserved] ...

  9. 28 CFR 39.161-39.169 - [Reserved

    Science.gov (United States)

    2010-07-01

    ... 28 Judicial Administration 1 2010-07-01 2010-07-01 false [Reserved] 39.161-39.169 Section 39.161-39.169 Judicial Administration DEPARTMENT OF JUSTICE ENFORCEMENT OF NONDISCRIMINATION ON THE BASIS OF HANDICAP IN PROGRAMS OR ACTIVITIES CONDUCTED BY THE DEPARTMENT OF JUSTICE §§ 39.161-39.169 [Reserved] ...

  10. Sartre y la crítica inglesa

    Directory of Open Access Journals (Sweden)

    Alfonso Hanssen

    1967-02-01

    Full Text Available Fuera de unos ensayos en revistas ("Times literary supplement", ('Esprit", "Les nouvelles littéraires", "Le Fígaro littéraire" y de alguno que otro libro de poca resonancia -pues no hemos visto que se imponga sobre los medios intelectuales- la crítica literaria formal sobre Sartre (no formalista ha sido realmente avara. En cambio, los órganos periódicos de expresión son insuficientes para tratar con el Sartre político, con el filósofo Sartre (la ensayística lo ha vulgarizado en razón del insistente uso de su terminología y con el Sartre revolucionario, el más conocido de todos, al parecer por los hechos y polémicas internacionales en que se ha puesto de protagonista.

  11. Miopatias distais: análise clínica, laboratorial, eletromiográfica, histológico-histoquímica de oito casos

    Directory of Open Access Journals (Sweden)

    Lineu C. Werneck

    1993-11-01

    Full Text Available As miopatias distais são entidades raras e de difícil classificação. Descrevemos oito casos de miopatias distais, cinco do sexo masculino e três do feminino, em que, o início dos sintomas ocorreu aos 10 anos em cinco e aos 20 em três. O início dos sintomas se deu na musculatura distal dos membros inferiores e a seguir dos membros superiores, posteriormente afetando as porções proximais dos quatro membros. As enzimas séricas de origem muscular mostraram discreta elevação em cinco casos, moderada em um e importante em dois. As eletromiografias sugeriram miopatia primária em quatro, desinervação em dois e era de tipo neuromiopático em outro. As biópsias musculares revelaram sinais de envolvimento misto (miopatia e desinervação em dois casos, miopatia crônica ativa em cinco e miopatia crônica em um. Quatro casos apresentavam vacúolos com conteúdo positivo na fosfatase ácida, em dois do tipo marginado. Seis casos mostraram importante aumento focal da fosfatase ácida, sugerindo patogenia com importante participação lisosomal. Dois dos casos foram classificados como miopatia distal autossômica recessiva variante de Welander; dois, como autossômica recessiva tipo Miyoshi; dois, como autossômica recessiva com vacúolos marginados (Myzuzawa e Nonaka; e dois, na classificação de miscelânea.

  12. Absolute timing of sulfide and gold mineralization: A comparison of Re-Os molybdenite and Ar-Ar mica methods from the Tintina Gold Belt, Alaska

    Science.gov (United States)

    Selby, D.; Creaser, R.A.; Hart, C.J.R.; Rombach, C.S.; Thompson, J.F.H.; Smith, Moira T.; Bakke, A.A.; Goldfarb, R.J.

    2002-01-01

    New Re-Os molybdenite dates from two lode gold deposits of the Tintina Gold Belt, Alaska, provide direct timing constraints for sulfide and gold mineralization. At Fort Knox, the Re-Os molybdenite date is identical to the U-Pb zircon age for the host intrusion, supporting an intrusive-related origin for the deposit. However, 40Ar/39Ar dates from hydrothermal and igneous mica are considerably younger. At the Pogo deposit, Re-Os molybdenite dates are also much older than 40Ar/39Ar dates from hydrothermal mica, but dissimilar to the age of local granites. These age relationships indicate that the Re-Os molybdenite method records the timing of sulfide and gold mineralization, whereas much younger 40Ar/39Ar dates are affected by post-ore thermal events, slow cooling, and/or systemic analytical effects. The results of this study complement a growing body of evidence to indicate that the Re-Os chronometer in molybdenite can be an accurate and robust tool for establishing timing relations in ore systems.

  13. Investigation on Tensile Strength Ratio (TSR Specimen to Predict Moisture Sensitivity of Asphalt Pavements Mixture and Using Polymer to Reduce Moisture Damage

    Directory of Open Access Journals (Sweden)

    Mohammed Aziz Hameed Al-Shaybani

    2017-05-01

    Full Text Available Moisture damage of asphalt concrete is defined as losing the strength and Permanence caused by the active presence of moisture.The most common technique to reduce moisture damage is using modifiers with the asphalt binder or the aggregate.The goal of this study was to explore the effect of various modifiers of polymer on the moisture susceptibility mixture of asphaltic concrete pavement. Modifiers included in this research selected two kinds of polymers Crumb Rubber No 50 (CR No 50 and Methyl Methacrylates (MMA(which are available in the local markets in Iraq and have been used in three percentages for each type. These percentages are (5, 10 and 15% for (CR No 50 and (2.5, 5 and 7.5(% for (MMA.Each type of these polymers is blended with asphalt by wet process at constant blending times for a suitable range of temperatures. The experimental works showed that all polymers modified mixtures have indirect tensile strength higher than control asphalt mixtures, its about (2-15 %, dependent on different type of polymer and polymer concentration under predicted suitable blending time.Test results of indirect tensile strength indicated betterment in modifying the proprieties of mixture, the increased resistance mixture of asphalt concrete pavement versus moisture damage, and reduced the effect of water on asphalt concrete properties. The final result is the addition of (10% CR No 50 and (5% MMA to asphalt mixtures showed an improved mixture of asphalt concrete properties and produced strong mixtures for road construction.One model is predicted for tensile strength ratio [TSR]to estimate the effects of polymer modification on moisture susceptibility mixture of asphalt concrete.

  14. 39 CFR 3001.39 - Intermediate decisions.

    Science.gov (United States)

    2010-07-01

    ... 39 Postal Service 1 2010-07-01 2010-07-01 false Intermediate decisions. 3001.39 Section 3001.39 Postal Service POSTAL REGULATORY COMMISSION PERSONNEL RULES OF PRACTICE AND PROCEDURE Rules of General Applicability § 3001.39 Intermediate decisions. (a) Initial decision by presiding officer. In any proceedings in...

  15. Alpine orogenic evolution from subduction to collisional thermal overprint: The 40Ar/39Ar age constraints from the Valaisan Ocean, central Alps

    DEFF Research Database (Denmark)

    Wiederkehr, Michael; Sudo, Masafumi; Bousquet, Romain

    2009-01-01

    in general. The timing of high-pressure metamorphism, subsequent retrogression and following Barrow-type overprint was studied by 40Ar/39Ar dating of biotite and several white mica generations that are well characterized in terms of mineral chemistry, texture and associated mineral assemblages. Four distinct...

  16. Realismo crítico en investigación en ciencias sociales: una introducción

    Directory of Open Access Journals (Sweden)

    Jairo Parada Corrales

    2004-01-01

    Full Text Available Este artículo busca contribuir al conocimiento de la teoría del Realismo Crítico en ciencias sociales dentro de la esfera académica latinoamericana. Haciendo una revisión de los métodos del positivismo y la hermenéutica y de los conceptos de paradigma y la práctica científica, el autor nos permite comprender las principales características de las metodologías de investigación en ciencias sociales y las oportunidades y ventajas que la ‘nueva visión’ del Realismo Crítico ofrece a aquellos interesados en producción de conocimiento científico, ello sin dejar de reconocer las contribuciones precedentes, sus fallas actuales y los desafíos futuros.

  17. Wetting of polymer melts on coated and uncoated steel surfaces

    Science.gov (United States)

    Vera, Julie; Contraires, Elise; Brulez, Anne-Catherine; Larochette, Mathieu; Valette, Stéphane; Benayoun, Stéphane

    2017-07-01

    A comparative study of the wetting of three different commercial polymer melts on various coated and uncoated steel surfaces is described in this report. The wettability of steel and coatings (three different titanium nitride coatings, TiN, TiNOx, TiNOy, a chromium coating, CrN, and a diamond-like carbon coating, DLC) used for mold in polymer processing is determined at different temperatures between 25 °C and 120 °C. Contact angle measurements of melted polypropylene (PP), Acrylonitrile Butadiene Styrene (ABS) and Polycarbonate (PC) on steel and on the different coatings were performed to investigate the wetting behavior under closer-to-processing conditions. Recommendations for good measurement conditions were proposed. Moreover, the surface free energy of each melt polymer was determined. The works of adhesion between all polymers and all substrates were established. Among all tested polymers, the lowest value of the works of adhesion is calculated for ABS and for PC thereafter, and the highest value is calculated for PP. These results will be particularly important for such applications as determining the extent to which these polymers can contribute to the replication quality in injection molding.

  18. Modelo predictivo de riesgo de morosidad para créditos bancarios usando datos simulados

    Directory of Open Access Journals (Sweden)

    Claudio Alfredo Lopez Miranda

    2013-06-01

    Full Text Available Un problema grave en las instituciones de crédito son los prestamos no recuperados, por lo que al momento de la solicitud, es deseable un modelo matemático para predecir el riesgo de tener un cliente potencialmente moroso, ya que su capacidad económica no garantiza por si sola el pago. Este trabajo presenta, a través de datos simulados, una técnica estadística conocida como regresión logística para predecir la probabilidad de no recuperar un crédito, con base al perfil socioeconómico del cliente, considerando el número de dependientes económicos, numero de impagos previos, su empleo, destino del crédito y salario mensual. El modelo predictor logra una tasa aciertos de 95% para clientes morosos y una tasa global del 70% de clasificaciones correctas. Los resultados sirven para apreciar los indicadores estadísticos conocidos, como la razón de ventajas por categorías. Por ejemplo, por cada crédito previo no pagado del cliente, se estima que el riesgo es 3.7 veces mayor y por cada $1,000.00 de incremento en el salario se estima que el riesgo (multiplicativo disminuye por un factor del 80%.

  19. Study of the weekly irrigation cycle of a cultivated field in a semi-arid area (Marrakech region, Morocco) by using CR-39 and LR-115 II track detectors and radon as a natural tracer

    International Nuclear Information System (INIS)

    Misdaq, M.A.; Essaouif, Z.

    2007-01-01

    Uranium ( 238 U) and thorium ( 232 Th) concentrations were measured in the soil of a cultivated field situated in a semi-arid area (Marrakech, Morocco) by using CR-39 and LR-115 type II solid state nuclear track detectors (SSNTDs). The same track detectors were used for measuring alpha- and beta-activities due to radon and thoron gases emanating from the soil of the studied irrigated agricultural field. The influence of the humidity (soil water content), soil depth and climate conditions on the weekly irrigation cycle of the studied cultivated field was investigated by exploiting radon measurements

  20. Características de los casos graves hospitalizados por gripe pandémica (H1N1 2009 en Cataluña

    Directory of Open Access Journals (Sweden)

    Pere Godoy

    2011-01-01

    Full Text Available Fundamentos. Las pandemias de gripe pueden comportar una mayor gravedad. El objetivo fue determinar las características de los casos graves hospitalizados de gripe pandémica en Cataluña y estudiar factores de riesgo de ingreso en CI. Métodos: e realizó un estudio epidemiológico observacional y prospectivo de los casos nuevos de gripe pandémica hospitalizados por su gravedad en el período: junio del 2009 hasta mayo del 2010. e solicitó a los centros sanitarios la declaración de los casos que cumplieron la definición de caso grave y en los que se confirmó la presencia del virus pandémico. Mediante una encuesta epidemiológica se recogió información sobre variables demográficas, clínica, factores de riesgo, tratamiento y evolución clínica. Las diferencias entre los casos en CI respecto al resto de casos graves se estudiaron con la odds ratio ajustada (ORa mediante un modelo de regresión logística no condicional. Resultados: e detectaron 773 casos graves de gripe pandémica; 465 (60,2% presentaron al menos un factor de riesgo y los más prevalentes fueron: embarazo 19 (13%, asma 87 (12%; enfermedad pulmonar obstructiva crónica 87 (11,4% y cardiopatías 80 (10,5%. Precisaron ingreso en una unidad de cuidados intensivos 293 pacientes (37,9%. Los factores asociados al ingreso en CI fueron la obesidad IMC>40 (ORa=2,5; IC 95% 1,4-4,5 y la enfermedad hepática crónica (ORa=2,3; IC 95% 1,1-4,8. Conclusiones: e confirma la alta prevalencia de embarazo, enfermedades respiratorias crónicas, diabetes y obesidad entre los casos graves. La obesidad mórbida se comporta como un factor de riesgo de ingreso en CI y por ello debe ser un indicador de vacunación antigripal.

  1. High throughput on-chip analysis of high-energy charged particle tracks using lensfree imaging

    Energy Technology Data Exchange (ETDEWEB)

    Luo, Wei; Shabbir, Faizan; Gong, Chao; Gulec, Cagatay; Pigeon, Jeremy; Shaw, Jessica; Greenbaum, Alon; Tochitsky, Sergei; Joshi, Chandrashekhar [Electrical Engineering Department, University of California, Los Angeles, California 90095 (United States); Ozcan, Aydogan, E-mail: ozcan@ucla.edu [Electrical Engineering Department, University of California, Los Angeles, California 90095 (United States); Bioengineering Department, University of California, Los Angeles, California 90095 (United States); California NanoSystems Institute (CNSI), University of California, Los Angeles, California 90095 (United States)

    2015-04-13

    We demonstrate a high-throughput charged particle analysis platform, which is based on lensfree on-chip microscopy for rapid ion track analysis using allyl diglycol carbonate, i.e., CR-39 plastic polymer as the sensing medium. By adopting a wide-area opto-electronic image sensor together with a source-shifting based pixel super-resolution technique, a large CR-39 sample volume (i.e., 4 cm × 4 cm × 0.1 cm) can be imaged in less than 1 min using a compact lensfree on-chip microscope, which detects partially coherent in-line holograms of the ion tracks recorded within the CR-39 detector. After the image capture, using highly parallelized reconstruction and ion track analysis algorithms running on graphics processing units, we reconstruct and analyze the entire volume of a CR-39 detector within ∼1.5 min. This significant reduction in the entire imaging and ion track analysis time not only increases our throughput but also allows us to perform time-resolved analysis of the etching process to monitor and optimize the growth of ion tracks during etching. This computational lensfree imaging platform can provide a much higher throughput and more cost-effective alternative to traditional lens-based scanning optical microscopes for ion track analysis using CR-39 and other passive high energy particle detectors.

  2. Adsorción de cr(vi) por cocos nucífera l. en residuales de fibrocemento en santiago de cuba

    OpenAIRE

    Pérez Silva, Rosa María; Calzado Lamela, Orlindes; Cascaret Carmenaty, Dannis Adrián; Tur Naranjo, Enieyis

    2014-01-01

    Título en ingles: Cr(VI) adsorption by Cocos nucífera L. in wastewater of fibrocement from Santiago de CubaTítulo corto: Adsorción de Cr(VI)  por Cocos nucífera L.Resumen:  La adsorción y/o formación de complejos de metales pesados basados en la actividad química de la biomasa, es el proceso conocido como biosorción y es la base de una nueva tecnología para su remoción en efluentes industriales y su posterior recuperación. En esta tecnología se pueden utilizar diferentes tipos de biomasas tal...

  3. Complement-fixing antibodies against denatured HLA and MICA antigens are associated with antibody mediated rejection.

    Science.gov (United States)

    Cai, Junchao; Terasaki, Paul I; Zhu, Dong; Lachmann, Nils; Schönemann, Constanze; Everly, Matthew J; Qing, Xin

    2016-02-01

    We have found antibodies against denatured HLA class I antigens in the serum of allograft recipients which were not significantly associated with graft failure. It is unknown whether transplant recipients also have denatured HLA class II and MICA antibodies. The effects of denatured HLA class I, class II, and MICA antibodies on long-term graft outcome were further investigated based on their ability to fix complement c1q. In this 4-year retrospective cohort study, post-transplant sera from 975 kidney transplant recipients were tested for antibodies against denatured HLA/MICA antigens and these antibodies were further classified based on their ability to fix c1q. Thirty percent of patients had antibodies against denatured HLA class I, II, or MICA antigens. Among them, 8.5% and 21.5% of all patients had c1q-fixing and non c1q-fixing antibodies respectively. There was no significant difference on graft survival between patients with or without antibodies against denatured HLA/MICA. However, when these antibodies were further classified according to their ability to fix c1q, patients with c1q-fixing antibodies had a significantly lower graft survival rate than patients without antibodies or patients with non c1q-fixing antibodies (p=0.008). In 169 patients who lost renal grafts, 44% of them had c1q-fixing antibodies against denatured HLA/MICA antigens, which was significantly higher than that in patients with functioning renal transplants (25%, pantibodies were more significantly associated with graft failure caused by AMR (72.73%) or mixed AMR/CMR (61.9%) as compared to failure due to CMR (35.3%) or other causes (39.2%) (p=0.026). Transplant recipients had antibodies against denatured HLA class I, II, and MICA antigens. However, only c1q-fixing antibodies were associated with graft failure which was related to antibody mediated rejection. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. Composite hydrogels of bio-inspired protein polymers : mechanical and structural characterization

    NARCIS (Netherlands)

    Rombouts, W.H.

    2015-01-01

    In this thesis we presented various combinations of custom-designed protein polymers that formed composite hydrogels. In chapter 2, composite hydrogels were prepared by mixing silk-like block copolymers (CP2SE48CP2) with collagen-like block copolymers (T9CR4T9). We found that by

  5. La protección de infraestructuras críticas

    Directory of Open Access Journals (Sweden)

    Mónica Miranzo

    2014-05-01

    Full Text Available Los ataques contra el World Trade Center en septiembre de 2001 pusieron de relevancia las nuevas amenazas y vulnerabilidades con las que los Estados deben lidiar en la actualidad al plantear la seguridad de las infraestructuras críticas. Un ataque de este tipo conlleva pérdidas tanto de vidas humanas como económicas, así como también afecta a la credibilidad política de los gobiernos. Sumado a la cada vez mayor demanda de unos recursos finitos y menguantes, así como un contexto de cambio climático y reajuste de la balanza de poder internacional, esta situación ha supuesto que las estrategias de seguridad nacionales de muchos países, entre ellos España, den una mayor importancia a la seguridad de las infraestructuras críticas. No obstante, a pesar de que la Estrategia de Seguridad Nacional tanto de 2009 como de 2013 ponen a España en línea con las directivas europeas al respecto, no hemos asistido a un desarrollo de la materia más allá de unas líneas de actuación generales.

  6. Estudo da modificação química de polidienos do tipo SBR e BR Study of chemical modification of SBR and BR polydiene

    Directory of Open Access Journals (Sweden)

    Tatiana L. A. C. Rocha

    2004-12-01

    Full Text Available A utilização de modificações químicas de polidienos comerciais tem sido estudada como um meio alternativo à síntese de novos polímeros, para otimização das propriedades finais destes materiais através da introdução de diferentes grupamentos reativos na cadeia polimérica. A modificação química pode ser feita através de diferentes métodos, os quais podem ser realizados tanto em solução como em massa, onde podem ser destacadas as reações de epoxidação, sulfonação, maleinização, carboxilação, etc. Neste trabalho foi estudado o método de epoxidação de borrachas do tipo SBR e BR. Foi possível observar que mesmo pequenos graus de modificação química causam mudanças marcantes nas propriedades finais dos polímeros, como determinado para a temperatura de transição vítrea.Chemical modification of polydiene has been studied as an alternative route to obtain modified polymers with improved final properties. This improvement is due to the introduction of different kinds of reactive groups into a polymer chain, and it can be done in solution as well as in bulk. The chemical modification can be carried out by different methods such as epoxidation, maleination, carboxylation, sulfonation etc. In this work we show that in the epoxidation of SBR and BR even a small degree of modification can change the final properties of the polymer, as it occurred for the glass transition temperature.

  7. Tungsten atomic layer deposition on polymers

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, C.A. [Department of Chemistry and Biochemistry, University of Colorado, Boulder, Colorado 80309-0215 (United States); McCormick, J.A. [Department of Chemical and Biological Engineering, University of Colorado, Boulder, Colorado 80309-0424 (United States); Cavanagh, A.S. [Department of Physics, University of Colorado, Boulder, Colorado 80309-0390 (United States); Goldstein, D.N. [Department of Chemistry and Biochemistry, University of Colorado, Boulder, Colorado 80309-0215 (United States); Weimer, A.W. [Department of Chemical and Biological Engineering, University of Colorado, Boulder, Colorado 80309-0424 (United States); George, S.M. [Department of Chemistry and Biochemistry, University of Colorado, Boulder, Colorado 80309-0215 (United States); Department of Chemical and Biological Engineering, University of Colorado, Boulder, Colorado 80309-0424 (United States)], E-mail: Steven.George@Colorado.Edu

    2008-07-31

    Tungsten (W) atomic layer deposition (ALD) was investigated on a variety of polymer films and polymer particles. These polymers included polyethylene, polyvinyl chloride, polystyrene, polycarbonate, polypropylene and polymethylmethacrylate. The W ALD was performed at 80 {sup o}C using WF{sub 6} and Si{sub 2}H{sub 6} as the gas phase reactants. W ALD on flat polymer films can eventually nucleate and grow after more than 60 AB cycles. X-ray photoelectron spectroscopy studies of W ALD on polystyrene after 50 AB cycles suggested that tungsten nanoclusters are present in the W ALD nucleation regime. The W ALD nucleation is greatly facilitated by a few cycles of Al{sub 2}O{sub 3} ALD. W ALD films were grown at 80 {sup o}C on spin-coated polymers on silicon wafers after 10 AB cycles of Al{sub 2}O{sub 3} ALD. The W ALD film was observed to grow linearly with a growth rate of 3.9 A per AB cycle on the polymer films treated with the Al{sub 2}O{sub 3} ALD seed layer. The W ALD films displayed an excellent, mirror-like optical reflectivity. The resistivity was 100-400 {mu}{omega} cm for W ALD films with thicknesses from 95-845 A. W ALD was also observed on polymer particles after W ALD in a rotary reactor. Without the Al{sub 2}O{sub 3} ALD seed layer, the nucleation of W ALD directly on the polymer particles at 80 {sup o}C required > 50 AB cycles. In contrast, the polymer particles treated with only 5 AB cycles of Al{sub 2}O{sub 3} ALD were observed to blacken after 25 AB cycles of W ALD. W ALD on polymers may have applications for flexible optical mirrors, electromagnetic interference shielding and gas diffusion barriers.

  8. 10 CFR 39.39 - Records of material use.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Records of material use. 39.39 Section 39.39 Energy NUCLEAR REGULATORY COMMISSION LICENSES AND RADIATION SAFETY REQUIREMENTS FOR WELL LOGGING Equipment § 39.39 Records of material use. (a) Each licensee shall maintain records for each use of licensed...

  9. Improved contrast polymer light-emitting diode with optical interference layers

    International Nuclear Information System (INIS)

    Liu, H.Y.; Sun, R.G.; Yang, K.X.; Peng, J.B.; Cao, Y.; Joo, S.K.

    2007-01-01

    An improved contrast polymer light diode based on the destructive optical interference layers deposited between the glass substrate and ITO anode is fabricated. It is unnecessary to be considered that the additional optical interference structure will impede carrier injection from the electrode to the carrier-transporting layer. Due to the quarter-wavelength thickness of medial ITO layer, the reflected light from first Cr layer is inverted 180 o out of phase with the reflected light from second Cr layer, resulting in the destructive interference. It is evident that the contrast ratio of the device with the optical interference structure is about three times higher than that of the conventional device

  10. Determination of the radial profile of the photoelastic coefficient of polymer optical fibers

    Science.gov (United States)

    Acheroy, Sophie; Merken, Patrick; Geernaert, Thomas; Ottevaere, Heidi; Thienpont, Hugo; Berghmans, Francis

    2016-04-01

    We determine the radial profile of the photoelastic constant C(r) in two single mode and one multimode polymer optical fibers (POFs), all fabricated from polymethylmethacrylate (PMMA). To determine C(r) we first determine the retardance of the laterally illuminated fiber submitted to a known tensile stress uniformly distributed over the fiber cross-section. Then we determine the inverse Abel transform of the measured retardance to finally obtain C(r). We compare two algorithms based on the Fourier theory to perform the inverse transform. We obtain disparate distributions of C(r) in the three fibers. The mean value of C(r) varies from -7.6×10-14 to 5.4×10-12 Pa-1. This indicates that, in contrast to glass fibers, the radial profile of the photoelastic constant can considerable vary depending on the type and treatment of POFs, even when made from similar materials, and hence the photoelastic constant should be measured for each type of POF.

  11. Urgencia hipertensiva secundaria a enfermedad poliquística renal autosómica recesiva en lactante. Reporte de caso

    Directory of Open Access Journals (Sweden)

    Roxana Quisbert-Cruz

    2017-06-01

    Full Text Available La enfermedad poliquística renal asociada a la fibrosis hepática congénita es una enfermedad hereditaria; se encuentra dentro del espectro de las enfermedades fibroquísticas hepatorrenales. Su frecuencia estimada es de 1 en 20.000 nacidos vivos para la variedad de enfermedad poliquística renal autosómica recesiva y más rara para la variedad autosómica dominante. Se presenta un reporte de caso de un paciente cuyo padecimiento se inició con crisis hipertensiva de difícil control, debido a enfermedad poliquística renal y fibrosis hepática congénita, presentación clínica poco frecuente; cabe mencionar sobre la importancia del control de la tensión arterial para prevenir complicaciones causadas por la hipertensión arterial: hipertrofia cardiaca, falla cardiaca y retinopatía crónica.

  12. Distribution of Cr atoms in the surface zone of Fe-rich Fe–Cr alloys quenched into various media: Mössbauer spectroscopic study

    International Nuclear Information System (INIS)

    Dubiel, Stanisław M.; Cieślak, Jakub; Żukrowski, Jan

    2015-01-01

    Graphical abstract: Chromium depletion, Δx = x_k − x, in Fe_1_0_0_−_xCr_x (x = 2.2, 3.9, 6.4, 8.5, 10.25, 10.75, 14.9, 15.15) alloys quenched into LN (left panel) and those quenched onto brass (right panel) as found from CEMS (pre surface zone) and TRANS (bulk) Mössbauer spectra (x_k – Cr content in the pre surface or bulk as estimated from the average hyperfine field found for the quenched samples). - Highlights: • Effect of quenching media on Cr atom distribution in Fe–Cr alloys was determined. • Significant differences between bulk and pre surface zone were revealed. • Quenching into water and LH resulted in surface oxidation of samples. • Samples quenched onto a block of brass were not oxidized. - Abstract: Effect of a quenching medium (water, liquid nitrogen and block of brass) on a distribution of Cr atoms in the surface zone of Fe_1_0_0_−_xCr_x (x ≤ 19) alloys was studied with the Mössbauer spectroscopy. The distribution of Cr atoms was expressed in terms of the Cowley–Warren short-range order (SRO) parameters: 〈α_1〉 for the first neighbor-shell, 〈α_2〉 for the second neighbor-shell and 〈α_1_2〉 for both neighbor-shells. It was revealed that none of the quenching media resulted in a random distribution of atoms, yet the degree of randomness was the highest for the samples quenched onto the block of brass. The quenching into water and liquid nitrogen caused a partial oxidation of samples’ surface accompanied by a chromium depletion of the bulk. Quantitative analysis of various phases in the studied samples both in their bulk as well as in pre surface zones was carried out.

  13. Phase Relations and Miscibility in Polymer Blends Containing Copolymers.

    Science.gov (United States)

    1986-04-15

    MacKnight, W. J ., Pure Appl. Chem. 52, 409 (1980). 36. Vukovic , R., Kuresevic, V., Karasz, F. E., and MacKnight, W. J ., Thermochim. Acta 54, 349 (1982). 37... Vukovic , R., Karasz, F. E., and MacKnight, W. J ., Polymer 24, 529 (1983). 38. Vukovic , R., Karasz, F. E., and MacKnight, W. J ., J . Appl. Polymer Sci...28, 219 (1983). 39. Zacharius, S. L., ten Brinke, G., MacKnight, W. J ., and Karasz, F. E., Macromolecules 16, 381 (1983). 40. Vukovic , R., Kuresevic

  14. Morphological and mechanical analysis of electrospun shape memory polymer fibers

    Energy Technology Data Exchange (ETDEWEB)

    Budun, Sinem [Institute of Pure and Applied Science, Marmara University, 34722 Istanbul (Turkey); İşgören, Erkan [Textile Technology, Technical Education Faculty, Marmara University, 34722 Istanbul (Turkey); Erdem, Ramazan, E-mail: ramazanerdem@akdeniz.edu.tr [Textile Technologies, Serik G-S. Sural Vocational School of Higher Education, Akdeniz University, 07500 Antalya (Turkey); Yüksek, Metin [Textile Engineering, Technology Faculty, Marmara University, 34722 Istanbul (Turkey)

    2016-09-01

    Highlights: • Fiber morphology of PU based shape memory fibers varied especially with polymer concentration and applied voltage. • The smallest diameter (381 ± 165 nm) and almost uniform (without bead) fibers were belonged to the sample Y10K30 with a feeding rate of 1 ml/h and an applied voltage of 30 kV at 24.5 cm distance. • All calculated shape fixity results were above 80% and the best value (92 ± 4%) was obtained for Y10K30. • All gained shape recovery results were determined above 100% and the highest measurement (130 ± 4%) was belonged to Y15K39. • The greatest tensile property was obtained for Y10K30 (14.7 ± 3.2 MPa) in machine direction and for Y10K39 (12.9 ± 0.8 MPa) in transverse direction. Y15K39 (411 ± 24%) and Y20K30 (402 ± 34%) possessed the highest elongation results compared with the other electrospun webs. - Abstract: Shape memory block co-polymer Polyurethane (PU) fibers were fabricated by electrospinning technique. Four different solution concentrations (5 wt.%, 10 wt.%, 15 wt.% and 20 wt.%) were prepared by using Tetrahydrofuran (THF)/N,N-dimethylformamide (DMF) (50:50, v/v) as solvents, and three different voltages (30 kV, 35 kV and 38.9 kV) were determined for the electrospinning process. Solution properties were explored in terms of viscosity and electrical conductivity. It was observed that as the polymer concentration increased in the solution, the conductivity declined. Morphological characteristics of the obtained fibers were analyzed through Scanning Electron Microscopy (SEM) measurements. Findings indicated that fiber morphology varied especially with polymer concentration and applied voltage. Obtained fiber diameter ranged from 112 ± 34 nm to 2046 ± 654 nm, respectively. DSC analysis presented that chain orientation of the polymer increased after electrospinning process. Shape fixity and shape recovery calculations were realized. The best shape fixity value (92 ± 4%) was obtained for Y10K30 and the highest shape

  15. Composición bioquímica y toxicidad de colonias comestibles de la cianobacteria andina Nostoc sp. Llayta

    OpenAIRE

    Galetovic, Alexandra; E. Araya, Jorge; Gómez-Silva, Benito

    2017-01-01

    RESUMEN Llayta es el nombre asignado a la biomasa seca de macrocolonias de una cianobacteria filamentosa, clasificada como Nostoc sp. Llayta crece en humedales andinos de Sudamérica y ha sido considerada como un ingrediente alimenticio desde tiempos precolombinos. Este estudio pretende contribuir a la definición de la calidad nutritiva de la Llayta, proporcionando información sobre su composición bioquímica e identificar aspectos críticos de interés toxicológico. Los resultados mostraron que ...

  16. Diabetes na infância / adolescência: conhecendo a dinâmica familiar

    Directory of Open Access Journals (Sweden)

    Michelle Darezzo Rodrigues Nunes

    2007-04-01

    Full Text Available A doença crônica apresenta como peculiaridades marcantes duração e risco de complicações, exigindo cuidados permanentes, colocando em evidência o papel da família, principalmente quando se refere à criança. Neste estudo objetivamos identificar quais os significados que a situação de doença crônica, diabetes, gera na dinâmica familiar. O referencial teórico e metodológico foram INTERACIONISMO SIMBÓLICO e TEORIA FUNDAMENTADA NOS DADOS, respectivamente. A pesquisa foi realizada no primeiro semestre de 2004, com seis famílias, entrevistadas com a questão norteadora “O que mudou na dinâmica familiar após a descoberta do diabetes do filho?” Na categorização dos dados identificamos 4 grandes temas: “Vida girando em torno da doença do filho” a descoberta da doença insere-se na história da família como algo que divide a vida em antes e depois; “Buscando algo que os fortaleça” refere-se ao conhecimento e equilíbrio emocional para cuidar do filho; “Precisando alterar a rotina” a mudança é inevitável e radical, sendo a alimentar a mais evidente; “Convivendo com o perigo” é vivenciar constante preocupação com as descompensações. Cada vez mais é necessário, para a enfermagem e demais profissionais da saúde, compreender as demandas de cuidado manifestadas pela família de modo a desenvolver ações que tenham ressonância efetiva sobre essa população.

  17. Groundwater contaminated with hexavalent chromium [Cr (VI)]: a health survey and clinical examination of community inhabitants (Kanpur, India).

    Science.gov (United States)

    Sharma, Priti; Bihari, Vipin; Agarwal, Sudhir K; Verma, Vipin; Kesavachandran, Chandrasekharan N; Pangtey, Balram S; Mathur, Neeraj; Singh, Kunwar Pal; Srivastava, Mithlesh; Goel, Sudhir K

    2012-01-01

    We assessed the health effects of hexavalent chromium groundwater contamination (from tanneries and chrome sulfate manufacturing) in Kanpur, India. The health status of residents living in areas with high Cr (VI) groundwater contamination (N = 186) were compared to residents with similar social and demographic features living in communities having no elevated Cr (VI) levels (N = 230). Subjects were recruited at health camps in both the areas. Health status was evaluated with health questionnaires, spirometry and blood hematology measures. Cr (VI) was measured in groundwater samples by diphenylcarbazide reagent method. Residents from communities with known Cr (VI) contamination had more self-reports of digestive and dermatological disorders and hematological abnormalities. GI distress was reported in 39.2% vs. 17.2% males (AOR = 3.1) and 39.3% vs. 21% females (AOR = 2.44); skin abnormalities in 24.5% vs. 9.2% males (AOR = 3.48) and 25% vs. 4.9% females (AOR = 6.57). Residents from affected communities had greater RBCs (among 30.7% males and 46.1% females), lower MCVs (among 62.8% males) and less platelets (among 68% males and 72% females) than matched controls. There were no differences in leucocytes count and spirometry parameters. Living in communities with Cr (VI) groundwater is associated with gastrointestinal and dermatological complaints and abnormal hematological function. Limitations of this study include small sample size and the lack of long term follow-up.

  18. A microwave inverse Cerenkov Accelerator (MICA)

    International Nuclear Information System (INIS)

    Hirshfield, Jay L.

    1999-01-01

    The objective of this Phase II SBIR research program was to complete the final design originated during Phase I for a prototype Microwave Inverse Cerenkov Accelerator (MICA), to fabricate the-prototype MICA, and to test its performance as an electron accelerator. This report contains details of the design, predictions of accelerator performance, results of cold tests on the MICA structure, and details of the installation of MICA on the Yale Beam Physics Laboratory 6-MeV beamline. Discussion of future work is also included

  19. Repercussões oxi-hemodinâmicas do banho no paciente em estado crítico adulto hospitalizado: revisão sistemática Repercusiones de la oxigenación hemodinámicas en el baño en el paciente en estado crítico adulto hospitalizado: revisión sistemática Hemodynamic oxygenation effects during the bathing of hospitalized adult patients critically ill: systematic review

    Directory of Open Access Journals (Sweden)

    Rubia Aparecida Lacerda

    2010-04-01

    Full Text Available OBJETIVOS: identificar evidências científicas sobre as repercussões oxi-hemodinâmicas do banho no paciente adulto internado em estado crítico; verificar a possibilidade de estabelecimento de critérios para indicação do banho nesse paciente, com base em repercussões oxi-hemodinâmicas nas diferentes situações clínicas. MÉTODOS: Revisão sistemática da literatura primária e secundária, sem recorte temporal ou idiomático. Utilizada estratégia PIO: P (problema = "Intensive Care Units" e variações; I (intervenção = banho e variações; O (desfecho = "Hemodynamic Phenomena" / "Oxygen Consumption" e variações. Fontes: bases de dados CINAHL, DEDALUS; EMBASE, COCHRANE, LILACS, PubMed/MEDLINE; bibliotecas das Escolas de Enfermagem da Universidade Federal Fluminense e Universidade Federal do Rio de Janeiro; referências cruzadas e; artigos relacionados do Pubmed e ISI. RESULTADOS: De 44597 referências restaram seis quase-experimentos. Durante o banho, a saturação venosa mista de oxigênio declinou consideravelmente do baseline, restabelecendo-se 30 minutos após. CONCLUSÃO: Condições que aumentam o risco: banho em menos de quatro horas após a cirurgia cardíaca, posicionamento prolongado em decúbito lateral e tempo de banho superior a 20 minutos: manutenção da temperatura da água em 40°C, para proteção.OBJETIVOS: identificar evidencias científicas sobre las repercusiones de la oxigenación hemodinámica del baño en el paciente adulto internado en estado crítico; verificar la posibilidad de establecimiento de criterios para indicación del baño en ese paciente, con base en repercusiones de oxigenación hemodinámica en las diferentes situaciones clínicas. MÉTODOS: Revisión sistemática de la literatura primaria y secundaria, sin recorte temporal o idiomático. Se utilizó la estrategia PIO: P (problema = "Intensive Care Units" y variaciones; I (intervención = baño y variaciones; O (resultado = "Hemodynamic

  20. Liquidus projection of the Nb-Cr-Al system near the Al3(Nb,Cr) + Cr(Al,Nb) eutectic region

    International Nuclear Information System (INIS)

    Souza, S.A.; Ferrandini, P.L.; Nunes, C.A.; Coelho, A.A.; Caram, R.

    2006-01-01

    The system Nb-Cr-Al was investigated in the region near the Al 3 (Nb,Cr) + Cr(Al,Nb) eutectic and the liquidus projection of that region was determined based on the microstructural characterization of arc melted alloys. The characterization utilized scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS), differential thermal analysis (DTA) and X-ray diffraction (XRD). The results allowed one to determine three primary solidification liquidus surfaces ((Cr,Al) 2 Nb, Cr(Al,Nb) and Al 3 (Nb,Cr)), that are originated from the binary systems Cr-Nb, Cr-Al and Al-Nb. It is proposed the occurrence of the invariant reaction L + (Cr,Al) 2 Nb ↔ Al 3 (Nb,Cr) + Cr(Al,Nb) and of a point of minimum, which involves a three phase reaction, L ↔ Al 3 (Nb,Cr) + Cr(Al,Nb). All alloys studied showed formation of the Al 3 (Nb,Cr) + Cr(Al,Nb) eutectic as the last solidification step with Al(Nb)Cr 2 precipitating from Cr(Al,Nb)

  1. Cooperativismo de crédito : organização sistêmica : ênfase no Sistema SICREDI

    OpenAIRE

    Edson Pedro Schneider

    2006-01-01

    O cooperativismo formal surgiu na Inglaterra, em 1844. Porém, as atitudes que deram origem ao cooperativismo de crédito fundamentavam-se na motivação e na necessidade de solidariedade para auxiliar os pequenos agricultores e, em seguida, os operários menos favorecidos da Alemanha e, posteriormente, da Europa, submetidos à exploração dos mais abastados, o que resultou em dificuldades de sobrevivência. As instituições cooperativas asseguram a existência econômica e organizacional dos menos favo...

  2. Factores de riesgo de la cardiopatía isquémica

    Directory of Open Access Journals (Sweden)

    Liliam Gretel Cisneros Sánchez

    Full Text Available Introducción: la enfermedad arterial coronaria es una de las principales causas de mortalidad en todo el mundo. En su fisiopatología juega un papel importante el desarrollo y la progresión de la aterosclerosis coronaria, la cual está íntimamente relacionada con determinados hábitos de vida y ciertas características personales que se conocen como factores de riesgo. Objetivo: actualizar a los profesionales delaAtenciónPrimaria de Salud sobre los factores de riesgo de la Cardiopatía Isquémica. Métodos: se realizó una revisión bibliográfica en libros de Medicina y artículos científicos disponibles en revistas digitales, a través de buscadores de información. Se accedió a diferentes fuentes de información como bases de datos, libros electrónicos, revistas electrónicas, etcétera, de infomed e internet. Luego se hizo un análisis crítico sobre el tema, avalado por la en contrado en la literatura consultada. Desarrollo: la situación de las enfermedades cardiovascularesen el mundo ha pasado por distintas fases, en correspondencia con el desarrollo socioeconómico de los países y el aumento en la incidencia de los distintos factores de riesgo, los cuales influyen de manera diferente en la aparición de la Cardiopatía Isquémica. Conclusiones: es importante conocer la influencia de cada factor de riesgo cardiovascular en la aparición de la Cardiopatía Isquémica para tomar estrategias encaminadas al control de los mismos y evitar llegar a la enfermedad.

  3. Energetic metallic ion implantation in polymers via cost-effective laser-driven ion source

    Science.gov (United States)

    Tahir, Muhammad Bilal; Rafique, M. Shahid; Ahmed, Rabia; Rafique, M.; Iqbal, Tahir; Hasan, Ali

    2017-07-01

    This research work reports the ions emission from the plasma generated by Nd:YAG laser having wavelength 1.064 μm, power 1.1 MW, pulse energy 10 mJ and intensity 1011 W/cm2 irradiated at 70° with respect to the target normal to the ions. These ions were accelerated through a home-made extraction assembly by means of a high voltage DC power supply. The energy of these ions were measured using Thomson parabola technique which utilizes Solid State Nuclear Track Detector (CR-39) and confirmed by Faraday cup as well that exploits a well-known technique known as time of flight. Interestingly, a significant increase in energy (from 490 to 730 keV) was observed with a discrete increase in acceleration potential from 0 to 18 kV. Polyethylene terephthalate (PET) and polypropylene were exposed to this recently developed ion source facility, to authenticate the reliability of this facility. The surface of the polymer is affected when energy of the irradiated ion is increased, which is evident from the optical micrographs. An increase in electrical conductivity was also observed with the increase in ion energy.

  4. Evaluación de los beneficios del Método Mézières incluido al programa de fisioterapia respiratoria de los pacientes con enfermedad pulmonar obstructiva crónica

    OpenAIRE

    Massoni, Anne-Charlotte

    2016-01-01

    La Enfermedad Pulmonar Obstructiva Crónica (EPOC), es un trastorno respiratorio causado mayoritariamente por el tabaquismo y caracterizado por una obstrucción progresiva y parcialmente reversible de las vías respiratorias, hiperinflación pulmonaria, manifestaciones sistémicas, expectoración anormal. Es la tercera causa de mortalidad en el mundo y se clasifica en 2: el enfisema y la bronquitis crónica. Nos centraremos en el aumento de deformaciones posturales, de la ansiedad y del dolor, la di...

  5. Effect of Nb and Cr incorporation on the structural and magnetic properties of rapidly quenched FeCoSiB microwires

    Energy Technology Data Exchange (ETDEWEB)

    Sarkar, Partha; Roy, R.K.; Mitra, A. [NDE and Magnetic Materials Group, CSIR-National Metallurgical Laboratory, Jamshedpur 831007 (India); Panda, A.K., E-mail: akpanda@nmlindia.org [NDE and Magnetic Materials Group, CSIR-National Metallurgical Laboratory, Jamshedpur 831007 (India); Churyukanova, Margarita; Kaloshkin, Sergey [National University of Science and Technology, MISIS, Leninsky Prospect, 4, Moscow 119049 (Russian Federation)

    2012-08-15

    Rapidly quenched microwires with a nominal composition of Fe{sub 39}Co{sub 39}Si{sub 8}B{sub 14} (A{sub O}), Fe{sub 37}Co{sub 37}Nb{sub 4}Si{sub 8}B{sub 14} (A{sub N}) and Fe{sub 36}Co{sub 36}Nb{sub 4}Cr{sub 2}Si{sub 8}B{sub 14} (A{sub NC}) have been investigated. Devitrification of as-quenched microwires showed that crystallization temperatures increased with simultaneous incorporation of Nb and Cr as in A{sub NC} alloy. Addition of these elements also contributed to an increase in activation energy in A{sub N} and A{sub NC} alloys. Nb addition reduced the particle size, which became much finer in the case of the Cr-containing alloy. Although Nb addition did not have much effect on lowering the Curie temperature T{sub C} of the amorphous phase, Cr substitution lowered T{sub C} to 698 K from high values of 785 K and 787 K observed in the no. A{sub O} and A{sub NC} alloys, respectively. However, the Cr addition revealed a better Giant magneto-impedance (GMI) response compared to the other alloys. Such improved GMI properties in the Cr-containing alloy are attributed to lower values of the coercivity and magnetostriction in the alloy containing both Nb and Cr. - Highlights: Black-Right-Pointing-Pointer FeCoSiB based rapidly quenched microwires prepared by in-rotating-water quenching system. Black-Right-Pointing-Pointer Effect of Nb and Cr on the thermal and GMI behavior of FeCoSiB microwires has been investigated. Black-Right-Pointing-Pointer Effect of Nb and Cr on magnetic properties has also been investigated.

  6. La Crítica en el Pensamiento Turístico

    Directory of Open Access Journals (Sweden)

    Celeste Nava Jiménez

    2014-10-01

    Full Text Available La propuesta de una Teoría Crítica por encima de una Tradicional implica, hoy por hoy, el desenmascaramiento de la visión tradicionalista en los estudios del Turismo frente a una realidad que se torna compleja en lo social, económico, cultural, político, entre otros, y que está ávida de una forma diferente de estudio. El artículo se presenta en cuatro secciones, la primera da un panorama de los elementos centrales de la crítica. La segunda parte acerca al lector hacia los horizontes críticos de la Teoría Crítica, con la visión epistémica a partir de Roger Verneaux (2005 y de la Teoría Crítica de Horkheimer (1937. El objetivo del tercer apartado es analizar el concepto de crítica en Turismo, para dar respuesta a la pregunta ¿Ha tenido un avance crítico la investigación crítica en Turismo? y, la cuarta presenta una propuesta para la construcción de contenidos críticos en Turismo. El trabajo concluye con algunas reflexiones críticas para promover una Teoría Crítica como postura en la investigación y en la construcción de nuevos enunciados para el Turismo. The Critical in the Tourism Teory - This article applies a critical perspective to promoting a critical theory as a position in the research and the construction of news Tourism statements. The proposal of a Critical Theory beyond of a Traditional Theory in Tourism studies, implies to unmask the traditional vision in the Tourism studies field towards an unacceptable reality becoming more increasingly more complex, in social, economic, cultural, politics, among many others. This reality requires a new dynamic study form. The article examines critically four sections. The first provides an overview of core critical elements. Secondly approach to the reader towards the horizons of Critical Theory with the epistemological perspective of Roger Verneaux (2005 and Horkheimer´s Critical Theory (1937. The third section analyse the critical concept in Tourism, to provide an

  7. Inhibition of the HDAC/Suv39/G9a pathway restores the expression of DNA damage-dependent major histocompatibility complex class I-related chain A and B in cancer cells.

    Science.gov (United States)

    Nakajima, Nakako Izumi; Niimi, Atsuko; Isono, Mayu; Oike, Takahiro; Sato, Hiro; Nakano, Takashi; Shibata, Atsushi

    2017-08-01

    Immunotherapy is expected to be promising as a next generation cancer therapy. Immunoreceptors are often activated constitutively in cancer cells, however, such levels of ligand expression are not effectively recognized by the native immune system due to tumor microenvironmental adaptation. Studies have demonstrated that natural-killer group 2, member D (NKG2D), a major activating immunoreceptor, responds to DNA damage. The upregulation of major histocompatibility complex class I-related chain A and B (MICA/B) (members of NKG2D ligands) expression after DNA damage is associated with NK cell-mediated killing of cancer cells. However, the regulation of DNA damage-induced MICA/B expression has not been fully elucidated in the context of the types of cancer cell lines. In the present study, we found that MICA/B expression varied between cancer cell lines after DNA damage. Screening in terms of chromatin remodeling identified that inhibitors related to chromatin relaxation via post-translational modification on histone H3K9, i.e. HDAC, Suv39 or G9a inhibition, restored DNA damage-dependent MICA/B expression in insensitive cells. In addition, we revealed that the restored MICA/B expression was dependent on ATR as well as E2F1, a transcription factor. We further revealed that low‑dose treatment of an HDAC inhibitor was sufficient to restore MICA/B expression in insensitive cells. Finally, we demonstrated that HDAC inhibition restored DNA damage‑dependent cytotoxic NK activity against insensitive cells. Thus, the present study revealed that DNA damage‑dependent MICA/B expression in insensitive cancer cells can be restored by chromatin relaxation via the HDAC/Suv39/G9a pathway. Collectively, manipulation of chromatin status by therapeutic cancer drugs may potentiate the antitumor effect by enhancing immune activation following radiotherapy and DNA damage-associated chemotherapy.

  8. CO2 Selective, Zeolitic Imidazolate Framework-7 Based Polymer Composite Mixed-Matrix Membranes

    KAUST Repository

    Chakrabarty, Tina; Neelakanda, Pradeep; Peinemann, Klaus-Viktor

    2018-01-01

    CO2 removal is necessary to mitigate the effects of global warming but it is a challenging process to separate CO2 from natural gas, biogas, and other gas streams. Development of hybrid membranes by use of polymers and metal-organic framework (MOF) particles is a viable option to overcome this challenge. A ZIF-7 nano-filler that was synthesized in our lab was embedded into a designed polymer matrix at various loadings and the performance of the mixed matrix membranes was evaluated in terms of gas permeance and selectivity. Hybrid membranes with various loadings (20, 30 and 40 wt%) were developed and tested at room temperature by a custom made time lag equipment and a jump in selectivity was observed when compared with the pristine polymer. A commercially attractive region for the selectivity CO2 over CH4 was achieved with a selectivity of 39 for 40 wt% particle loading. An increase in selectivity was observed with the increase of ZIF-7 loadings. Best performance was seen at 40% ZIF-7 loaded membrane with an ideal selectivity of 39 for CO2 over CH4. The obtained selectivity was 105% higher for CO2 over CH4 than the selectivity of the pristine polymer with a slight decrease in permeance. Morphological characterization of such developed membranes showed an excellent compatibility between the polymer and particle adhesion.

  9. CO2 Selective, Zeolitic Imidazolate Framework-7 Based Polymer Composite Mixed-Matrix Membranes

    KAUST Repository

    Chakrabarty, Tina

    2018-05-17

    CO2 removal is necessary to mitigate the effects of global warming but it is a challenging process to separate CO2 from natural gas, biogas, and other gas streams. Development of hybrid membranes by use of polymers and metal-organic framework (MOF) particles is a viable option to overcome this challenge. A ZIF-7 nano-filler that was synthesized in our lab was embedded into a designed polymer matrix at various loadings and the performance of the mixed matrix membranes was evaluated in terms of gas permeance and selectivity. Hybrid membranes with various loadings (20, 30 and 40 wt%) were developed and tested at room temperature by a custom made time lag equipment and a jump in selectivity was observed when compared with the pristine polymer. A commercially attractive region for the selectivity CO2 over CH4 was achieved with a selectivity of 39 for 40 wt% particle loading. An increase in selectivity was observed with the increase of ZIF-7 loadings. Best performance was seen at 40% ZIF-7 loaded membrane with an ideal selectivity of 39 for CO2 over CH4. The obtained selectivity was 105% higher for CO2 over CH4 than the selectivity of the pristine polymer with a slight decrease in permeance. Morphological characterization of such developed membranes showed an excellent compatibility between the polymer and particle adhesion.

  10. Efecto de la presión de C2H2 sobre las propiedades tribológicas y mecánicas de recubrimientos de CrC depositados por evaporación por arco catódico (EAC

    Directory of Open Access Journals (Sweden)

    Maryory Astrid Gómez Botero

    2010-01-01

    Full Text Available Se obtuvieron recubrimientos monocapa de CrC por evaporación por arco catódico (EAC. Se investigaron las propiedades tribológicas de los recubrimientos mediante pruebas de deslizamiento en seco usando un tribómetro de bola sobre disco. Las propiedades mecánicas se estudiaron por nanoindentación dinámica. Los valores de los coeficientes de fricción de los recubrimientos monocapa de CrC mostraron buena correlación con el contenido de carbono de estos recubrimientos, presentando el más bajo coeficiente de fricción el recubrimiento con el mayor contenido de carbono. Después de las pruebas de fricción, tanto los recubrimientos como las esferas de acero usadas como contracuerpos presentaron partículas de desgaste de color marrón que sugieren la presencia de productos de reacciones triboquímicas. Las mejores propiedades mecánicas fueron obtenidas para los recubrimientos CrC con el más bajo contenido de carbono.

  11. Groundwater contaminated with hexavalent chromium [Cr (VI]: a health survey and clinical examination of community inhabitants (Kanpur, India.

    Directory of Open Access Journals (Sweden)

    Priti Sharma

    Full Text Available BACKGROUND: We assessed the health effects of hexavalent chromium groundwater contamination (from tanneries and chrome sulfate manufacturing in Kanpur, India. METHODS: The health status of residents living in areas with high Cr (VI groundwater contamination (N = 186 were compared to residents with similar social and demographic features living in communities having no elevated Cr (VI levels (N = 230. Subjects were recruited at health camps in both the areas. Health status was evaluated with health questionnaires, spirometry and blood hematology measures. Cr (VI was measured in groundwater samples by diphenylcarbazide reagent method. RESULTS: Residents from communities with known Cr (VI contamination had more self-reports of digestive and dermatological disorders and hematological abnormalities. GI distress was reported in 39.2% vs. 17.2% males (AOR = 3.1 and 39.3% vs. 21% females (AOR = 2.44; skin abnormalities in 24.5% vs. 9.2% males (AOR = 3.48 and 25% vs. 4.9% females (AOR = 6.57. Residents from affected communities had greater RBCs (among 30.7% males and 46.1% females, lower MCVs (among 62.8% males and less platelets (among 68% males and 72% females than matched controls. There were no differences in leucocytes count and spirometry parameters. CONCLUSIONS: Living in communities with Cr (VI groundwater is associated with gastrointestinal and dermatological complaints and abnormal hematological function. Limitations of this study include small sample size and the lack of long term follow-up.

  12. Contribución al estudio experimental del cancer III. Alteraciones de la corteza suprarrenal en la Carcinogenesis Química.

    Directory of Open Access Journals (Sweden)

    Oscar Miro-Quesada C

    1948-12-01

    Full Text Available 1.- Se hace un estudio crítico histo-químico funcional de la corteza suprarrenal en ratones homozigotes C3H (Strong sometidos a la cancerización química con 20-Metilcolantreno. 2.- Se describe un nuevo tipo de reacción funcional de dicha glándula bajo las condiciones experimentales empleadas, sugiriéndose la denominación de "atrofia-hiperactiva", en contraste con las alteraciones histo-químico funcionales de la corteza suprarrenal descritas por varios autores en animales portadores de injertos neoplásicos, las que corresponden al tipo de reacción funcional de la glándula caracterizado por "hipertrofia-hiperactiva". 3.- Los resultados obtenidos sugieren la intervención del sistema endocrino, via la corteza suprarrenal, durante el proceso de carcinogenesis química en el ratón homozigote de raza C3H (Strong.

  13. Low friction coefficient coatings Ni-Cr by magnetron sputtering, DC

    Directory of Open Access Journals (Sweden)

    Morales-Hernández, Jorge

    2015-09-01

    Full Text Available Magnetron Sputter Deposition technique with DC was used for the deposition of Ni-Cr coatings on AISI 316 SS like substrate. The cathode with a nominal composition Ni-22 at% Cr was prepared by Mechanical Alloying (MA technique, with a maximum milling time of 16 hours and, with a high energy SPEX 8000 mill. The coatings were made under Argon atmosphere at room temperature with a power of 100 W at different times of growth. Chemical composition, microstructure, topography, nanohardness and wear of the coatings were evaluated using the techniques of microanalysis by energy dispersive X-ray analyzer (EDAX, X-Ray Diffraction (XRD, Atomic Force Microscopy (AFM, Nano-indentation and pin-on-Disk, respectively. After milling, was not detected contamination in the mixtures. XRD analysis revealed that the microstructure of the Ni-Cr alloy was maintained in the coatings with respect to MA powders, with some degree of recrystallization. Nanohardness values were in the order of 8.8 GPa with a Young’s modulus of 195 GPa. The adhesion of the films was evaluated according to their resistance to fracture when these were indented at different loads using Vickers microhardness. The wear test results showed a decrease in the friction coefficient with respect to the increase of thickness’ films, getting a minimum value of 0.08 with a thickness of 1 μm and which correspond with the maximum growing time.La técnica de Deposición por Chisporroteo Magnético (Magnetron Sputtering con el proceso DC, fue usado para la deposición de los recubrimientos de Ni-Cr sobre acero inoxidable AISI 316 como sustrato. El cátodo con una composición nominal Ni-22 at% Cr fue preparado por la técnica de Aleado Mecánico (AM, con un tiempo máximo de molienda de 16 horas y con un molino de alta energía tipo SPEX 8000. Las películas se realizaron bajo una atmósfera de argón a temperatura ambiente con una potencia de 100 W a diferentes tiempos de crecimiento. La composición química

  14. EN LA TEORÍA ECONÓMICA DE DAVID RICARDO

    Directory of Open Access Journals (Sweden)

    FRANCISCO CORREA RESTREPO

    2015-01-01

    Full Text Available Este artículo tiene como objetivo central analizar el papel del recurso tierra en la teoría económica de David Ricardo como primer acercamiento al análisis económico de los recursos naturales. Esto se realiza mediante una revisión bibliográfica analítica de la obra de Ricardo y de otros autores en torno a la misma. En este sentido, se examina el concepto de renta de la tierra, así como los planteamientos en torno a la llamada ley de los rendimientos decrecientes. Asimismo, se establecen algunas reflexiones críticas con relación al enfoque de la renta de la tierra. Un resultado importante del trabajo es que en el análisis de la renta de Ricardo está ausente el concepto de costo de oportunidad, lo cual implica una reconsideración del concepto de renta para abordar el análisis económico de recursos naturales.

  15. 21 CFR 73.1350 - Mica-based pearlescent pigments.

    Science.gov (United States)

    2010-04-01

    ... LISTING OF COLOR ADDITIVES EXEMPT FROM CERTIFICATION Drugs § 73.1350 Mica-based pearlescent pigments. (a) Identity. (1) The color additive is formed by depositing titanium and/or iron salts onto mica, followed by...; titanium dioxide and iron oxide on mica. Mica used to manufacture the color additive shall conform in...

  16. 21 CFR 73.350 - Mica-based pearlescent pigments.

    Science.gov (United States)

    2010-04-01

    ... LISTING OF COLOR ADDITIVES EXEMPT FROM CERTIFICATION Foods § 73.350 Mica-based pearlescent pigments. (a) Identity. (1) The color additive is formed by depositing titanium salts onto mica, followed by heating to produce titanium dioxide on mica. Mica used to manufacture the color additive shall conform in identity to...

  17. Cr(III) reactivity and foot dermatitis in Cr(VI) positive patients

    DEFF Research Database (Denmark)

    Hansen, Malene Barré; Menné, Torkil; Johansen, Jeanne Duus

    2006-01-01

    Chromium allergy has become synonymous with Cr(VI) allergy. However, real exposure to chromium from leather products may include both Cr(III) and Cr(VI). In this study, we investigate the reactivity to both Cr(VI) and Cr(III) in consecutive patients to analyse the relation between foot eczema/leather...... to Cr(III). The increased risk was not due to a higher degree of sensitivity to Cr(VI). Leather was reported most frequently as the suspected cause of chromium dermatitis (54%). However, Cr(VI) allergics having foot eczema and positive or doubtful Cr(III) reactions often had positive reactions to other...

  18. Application of double-spike isotope dilution for the accurate determination of Cr(III), Cr(VI) and total Cr in yeast.

    Science.gov (United States)

    Yang, Lu; Ciceri, Elena; Mester, Zoltán; Sturgeon, Ralph E

    2006-11-01

    A method is presented for the simultaneous determination of Cr(III) and Cr(VI) in yeast using species-specific double-spike isotope dilution (SSDSID) with anion-exchange liquid chromatography (LC) separation and sector field inductively coupled plasma mass spectrometric (SF-ICP-MS) detection. Total Cr is quantitated using ID SF-ICP-MS. Samples were digested on a hot plate at 95+/-2 degrees C for 6 h in an alkaline solution of 0.5 M NaOH and 0.28 M Na2CO3 for the determination of Cr(III) and Cr(VI), whereas microwave-assisted decomposition with HNO3 and H2O2 was used for the determination of total Cr. Concentrations of 2,014+/-16, 1,952+/-103 and 76+/-48 mg kg-1 (one standard deviation, n=4, 3, 3), respectively were obtained for total Cr, Cr(III) and Cr(VI) in the yeast sample. Significant oxidation of Cr(III) to Cr(VI) (24.2+/-7.6% Cr(III) oxidized, n=3) and reduction of Cr(VI) to Cr(III) (37.6+/-6.5% Cr(VI) reduced, n=3) occurred during alkaline extraction and subsequent chromatographic separation at pH 7. Despite this significant bidirectional redox transformation, quantitative recoveries for both Cr(III) and Cr(VI) were achieved using the SSDSID method. In addition, mass balance between total Cr and the sum of Cr(III) and Cr(VI) concentrations was achieved. Method detection limits of 0.3, 2 and 30 mg kg-1 were obtained for total Cr, Cr(VI) and Cr(III), respectively, based on a 0.2-g sub-sample.

  19. Magnetoelectric effect in Cr2O3 thin films

    Science.gov (United States)

    He, Xi; Wang, Yi; Sahoo, Sarbeswar; Binek, Christian

    2008-03-01

    Magnetoelectric materials experienced a recent revival as promising components of novel spintronic devices [1, 2, 3]. Since the magnetoelectric (ME) effect is relativistically small in traditional antiferromagnetic compounds like Cr2O3 (max. αzz 4ps/m ) and also cross- coupling between ferroic order parameters is typically small in the modern multiferroics, it is a challenge to electrically induce sufficient magnetization required for the envisioned device applications. A straightforward approach is to increase the electric field at constant voltage by reducing the thickness of the ME material to thin films of a few nm. Since magnetism is known to be affected by geometrical confinement thickness dependence of the ME effect in thin film Cr2O3 is expected. We grow (111) textured Cr2O3 films with various thicknesses below 500 nm and study the ME effect for various ME annealing conditions as a function of temperature with the help of Kerr-magnetometry. [1] P. Borisov et al. Phys. Rev. Lett. 94, 117203 (2005). [2] Ch. Binek, B.Doudin, J. Phys. Condens. Matter 17, L39 (2005). [3] R. Ramesh and Nicola A. Spaldin 2007 Nature Materials 6 21.

  20. MICA: The Meta-Institute for Computational Astrophysics

    Science.gov (United States)

    McMillan, Stephen L. W.; Djorgovski, S. G.; Hut, P.; Vesperini, E.; Knop, R.; Portegies Zwart, S.

    2009-05-01

    We describe MICA, the Meta Institute for Computational Astrophysics, the first professional scientific and educational, non-profit organization based in virtual worlds [VWs]. Most MICA activities are currently conducted in Second Life, arguably the most popular and best developed VW; we plan to expand our presence into other VWs as those venues evolve. The goals of MICA include (1) exploration, development and promotion of VWs and virtual reality [VR] technologies for professional research in astronomy and related fields; (2) development of novel networking venues and mechanisms for virtual scientific communication and interaction, including professional meetings, visualization, and telecollaboration; (3) use of VWs and VR technologies for education and public outreach; and (4) exchange of ideas and joint efforts with other scientific disciplines in promoting these goals for science and scholarship in general. We present representative example of MICA activities and achievements, and outline plans for expansion of the organization. For more information on MICA, please visit http://mica-vw.org .

  1. Estudio de efectos dimensionales en pseudocerámicas ferroeléctricas

    Directory of Open Access Journals (Sweden)

    Melcón, M. J.

    1999-12-01

    Full Text Available With the objective to advance in the study of dimensional properties in ferroelectric materials, we have prepared a new kind of materials, which are going to be called “pseudoceramic”. These are, basically, composites that are constituted of milled single crystals packed tightly in different polymers. In these materials, we control, between other factors, grain-size and the thickness of polymeric matrix between grains. Therefore, we have a large range of pseudoceramics, over we study and measure ferro-piro-piezoelectric properties, and we related them with the dimensional aspects.

    Con el objetivo de avanzar en el estudio de la influencia de los parámetros dimensionales en las propiedades de materiales electrotérmicos, hemos fabricado materiales a los que llamaremos pseudocerámicas que, básicamente son composites de monocristales molidos embutidos en bases de diferentes polímeros. En estos materiales controlamos entre otros factores el tamaño de grano y el espesor de la matriz polimérica entre granos, disponiendo así de una amplia gama de pseudocerámicas en las que medimos y estudiamos propiedades ferro-piro-piezoeléctricas y las relacionamos con los aspectos dimensionales de las mismas. Se presentan los resultados correspondientes a la conformación del material y su respuesta eléctrica.

  2. Trasplante autólogo de células progenitoras derivadas de la médula ósea, por vía intramiocárdica, para revascularización en cardiopatía isquémica crónica Autologous intramyocardial transplant of bone marrow derived stem cells for revascularization in ischemic chronic cardiopathy

    Directory of Open Access Journals (Sweden)

    Óscar Velásquez

    2005-08-01

    Full Text Available Introducción: estudios experimentales y clínicos demuestran que la implantación intramiocárdica de células progenitoras derivadas de la médula ósea, produce angiogénesis y mejora la función cardiaca en pacientes con cardiopatía isquémica crónica. Metodología: este es el reporte del seguimiento a dos meses de un paciente con cardiopatía isquémica crónica no susceptible de revascularización quirúrgica o percutánea, a quien se le realizó ,por vía epicárdica, un implánte de células progenitoras derivadas de médula ósea movilizadas con factor de crecimiento granulocito-macrófago. Resultados: se demostró mejoría significativa en la sintomatología, en la capacidad funcional (1.8 MET a 10 MET, en el estado funcional (IV a I, en el tamaño del defecto de perfusión miocárdica por medicina nuclear, en la fracción de eyección y en la disminución del volumen sistólico final del ventrículo izquierdo, sin observar complicaciones relacionadas con el procedimiento. Conclusión: el trasplante de células progenitoras derivadas de la médula ósea es una terapia efectiva y segura para promover neovascularización y para mejorar la contractilidad y la perfusión miocárdica en los pacientes con cardiopatía isquémica crónica pobres candidatos a cirugía.Introduction: experimental and clinical studies have demonstrated that intramyocardial bone marrow derived stem cells implantation produce angiogenesis and improvement of cardiac function in patients with chronic ischemic cardiopathy. Methodology: this is a two months follow-up report of a patient with chronic ischemic cardiopathy not susceptible of surgical or percutaneous revascularization, to whom bone marrow stem cells mobilized with granulocyte - macrophage growth factor was implanted. Results: significant improvement was demonstrated in symptomatology, functional capacity (1.8 Mets to 10 Mets, functional state (IV to I, size of the myocardial perfusion defect by nuclear

  3. Avaliação físico-química de águas minerais comercializadas na região de Campinas, SP

    Directory of Open Access Journals (Sweden)

    Morgano Marcelo A.

    2002-01-01

    Full Text Available Com o objetivo de avaliar a qualidade de águas minerais, foram analisadas amostras, adquiridas em supermercados, de oito fontes localizadas no Estado de São Paulo entre agosto de 1999 e maio de 2000, com coletas trimestrais. Os resultados das análises físico-químicas mostraram que as amostras possuíam, em sua maioria, composição química dentro dos limites permitidos pela legislação brasileira, exceto quatro amostras, que apresentaram resultados na análise de cor acima de 5 unidades PtCo, uma amostra com pH fora da faixa recomendada de 4,0 a 9,0 e uma amostra com alcalinidade em hidróxidos em duas épocas de análise. Os resultados obtidos para as diferentes amostras variaram de acordo com as seguintes faixas: pH de 6,39 a 9,92, alcalinidade de 0,0 a 189,1mg L-1 de bicarbonato, dureza de 0,00 a 136,00mg L-1 de carbonato de cálcio, cor de 0,0 a 9,0 unidades de PtCo, turbidez de 0,00 a 2,00 FTU de turvação, sulfato de 0,00 a 55,67mg L-1, sulfeto de 0,00 a 0,002mg L-1, cloreto de 0,00 a 23,53mg L-1, fluoreto de 0,02 a 0,8mg L-1, alumínio de 0,01 a 0,09mg L-1, bário de 0,00 a 0,26mg L-1, cálcio de 0,53 a 28,35mg L-1, crômio de 0,00 a 0,01mg L-1, ferro de 0,00 a 0,03mg L-1, potássio de 0,39 a 3,27mg L-1, sódio de 0,53 a 97,29mg L-1, magnésio de 0,00 a 9,10mg L-1, manganês de 0,00 a 0,05mg L-1, zinco de 0,00 a 0,03mg L-1, chumbo de 0,00 a 0,01mg L-1 e lítio de 0,00 a 0,02mg L-1. Os elementos cádmio, cobre e cobalto apresentaram-se abaixo dos limites de detecção dos métodos.

  4. Estudio Clínico–Neurológico y Cráneo–Cervicométrico en la Acondroplasia.

    OpenAIRE

    Proaño Vallejo, Jorge

    2016-01-01

    En seis casos de acondroplasia se ha realizado un estudio clínico-neurológico y se ha establecido su correlación craneométrica y cervicométrica con el correspondiente análisis de la charnela cráneo-cervical en su triple faceta morfológica, dinámica y dimensional. En la exploración del desarrollo embriológico del sistema nervioso central y de sus envolturas óseas y meníngeas, se ha puesto especial &e...

  5. Correlation between bulk- and surface chemistry of Cr-tanned leather and the release of Cr(III) and Cr(VI)

    Energy Technology Data Exchange (ETDEWEB)

    Hedberg, Yolanda S., E-mail: yolanda@kth.se [KTH Royal Institute of Technology, School of Chemical Science and Engineering, Department of Chemistry, Division of Surface and Corrosion Science, SE-10044 Stockholm (Sweden); Institute of Environmental Medicine, Karolinska Institutet, Box 210, SE-17177 Stockholm (Sweden); Lidén, Carola, E-mail: carola.liden@ki.se [Institute of Environmental Medicine, Karolinska Institutet, Box 210, SE-17177 Stockholm (Sweden); Odnevall Wallinder, Inger, E-mail: ingero@kth.se [KTH Royal Institute of Technology, School of Chemical Science and Engineering, Department of Chemistry, Division of Surface and Corrosion Science, SE-10044 Stockholm (Sweden)

    2014-09-15

    Graphical abstract: - Highlights: • Released reducing/complexing leather-specific species can reduce released Cr(VI). • No co-released species enable the formation of Cr(VI) in solution. • The major Cr species released from leather in phosphate buffer was Cr(III) (>82%). • No Cr(VI) was released into artificial sweat. - Abstract: About 1–3% of the adult general population in Europe is allergic to chromium (Cr). The assessment of the potential release of Cr(III) and Cr(VI) from leather is hence important from a human health and environmental risk perspective. The Cr(VI) content in leather was recently restricted in the European Union. The aim of this study was to assess possible correlations between the bulk and surface chemistry of leather, released Cr(III) and Cr(VI), and capacities of co-released leather specific species to reduce and complex released Cr. Four differently tanned leathers were characterized by scanning electron microscopy with energy dispersive spectroscopy, X-ray photoelectron spectroscopy, attenuated total reflectance Fourier transform infrared (ATR-FTIR) spectroscopy, and the diphenylcarbazide colorimetric method. Their characteristics were compared with results on Cr(III) and Cr(VI) release into artificial sweat (ASW, pH < 6.5) and phosphate buffer (PB, pH 7.5–8.0), measured by means of spectrophotometry and atomic absorption spectroscopy. Co-released leather-specific species were shown to reduce Cr(VI), both in ASW and in PB. Their reduction capacities correlated with findings of the surface content of Cr and of released Cr. Leather samples without this capacity, and with less aromatic surface groups visible by ATR-FTIR, revealed Cr(VI) both at the surface and in solution (PB)

  6. Acute Antibody-Mediated Rejection in Presence of MICA-DSA and Successful Renal Re-Transplant with Negative-MICA Virtual Crossmatch.

    Directory of Open Access Journals (Sweden)

    Yingzi Ming

    Full Text Available The presence of donor-specific alloantibodies (DSAs against the MICA antigen results in high risk for antibody-mediated rejection (AMR of a transplanted kidney, especially in patients receiving a re-transplant. We describe the incidence of acute C4d+ AMR in a patient who had received a first kidney transplant with a zero HLA antigen mismatch. Retrospective analysis of post-transplant T and B cell crossmatches were negative, but a high level of MICA alloantibody was detected in sera collected both before and after transplant. The DSA against the first allograft mismatched MICA*018 was in the recipient. Flow cytometry and cytotoxicity tests with five samples of freshly isolated human umbilical vein endothelial cells demonstrated the alloantibody nature of patient's MICA-DSA. Prior to the second transplant, a MICA virtual crossmatch and T and B cell crossmatches were used to identify a suitable donor. The patient received a second kidney transplant, and allograft was functioning well at one-year follow-up. Our study indicates that MICA virtual crossmatch is important in selection of a kidney donor if the recipient has been sensitized with MICA antigens.

  7. Uma perspectiva realista crítica sobre ação coletiva em economia

    Directory of Open Access Journals (Sweden)

    THIAGO DUARTE PIMENTEL

    Full Text Available RESUMO A visão predominante na economia tradicional assume que o objeto de análise das relações econômicas é o indivíduo, seja pela interação econômica entre eles (troca seja pela interação econômica entre indivíduos e coisas (produção. Dificilmente a ciência econômica assume suposições a respeito de indivíduos organizados coletivamente. Em geral, quando o faz, assume que estas formas sejam um efeito agregado das ações individuais isoladas, ensejando assim uma posição baseada no individualismo metodológico. Em microeconomia, por exemplo, uma afirmação sobre um grupo de indivíduos, uma firma ou mesmo a sociedade, assume necessariamente que suas ações sejam abordadas a partir dos efeitos de maximizações individuais, ainda que isso exija a generalização de condições rígidas sobre o comportamento humano, improváveis para sustentar as crenças e os desejos individuais. Esse trabalho tem como objetivo apresentar um modelo de análise alternativo àquele paradigma, que simultaneamente esteja comprometido com uma análise realista e incorpore elementos contextuais e empíricos alusivos à conduta humana. Situando nosso foco no nível mesossociológico de análise, argumentamos que a análise da ação coletiva, fundamentada no realismo crítico, constitui-se numa alternativa para direcionar os estudos em economia.

  8. Hybrid Silicon Nanocone–Polymer Solar Cells

    KAUST Repository

    Jeong, Sangmoo

    2012-06-13

    Recently, hybrid Si/organic solar cells have been studied for low-cost Si photovoltaic devices because the Schottky junction between the Si and organic material can be formed by solution processes at a low temperature. In this study, we demonstrate a hybrid solar cell composed of Si nanocones and conductive polymer. The optimal nanocone structure with an aspect ratio (height/diameter of a nanocone) less than two allowed for conformal polymer surface coverage via spin-coating while also providing both excellent antireflection and light trapping properties. The uniform heterojunction over the nanocones with enhanced light absorption resulted in a power conversion efficiency above 11%. Based on our simulation study, the optimal nanocone structures for a 10 μm thick Si solar cell can achieve a short-circuit current density, up to 39.1 mA/cm 2, which is very close to the theoretical limit. With very thin material and inexpensive processing, hybrid Si nanocone/polymer solar cells are promising as an economically viable alternative energy solution. © 2012 American Chemical Society.

  9. Hybrid Silicon Nanocone–Polymer Solar Cells

    KAUST Repository

    Jeong, Sangmoo; Garnett, Erik C.; Wang, Shuang; Yu, Zongfu; Fan, Shanhui; Brongersma, Mark L.; McGehee, Michael D.; Cui, Yi

    2012-01-01

    Recently, hybrid Si/organic solar cells have been studied for low-cost Si photovoltaic devices because the Schottky junction between the Si and organic material can be formed by solution processes at a low temperature. In this study, we demonstrate a hybrid solar cell composed of Si nanocones and conductive polymer. The optimal nanocone structure with an aspect ratio (height/diameter of a nanocone) less than two allowed for conformal polymer surface coverage via spin-coating while also providing both excellent antireflection and light trapping properties. The uniform heterojunction over the nanocones with enhanced light absorption resulted in a power conversion efficiency above 11%. Based on our simulation study, the optimal nanocone structures for a 10 μm thick Si solar cell can achieve a short-circuit current density, up to 39.1 mA/cm 2, which is very close to the theoretical limit. With very thin material and inexpensive processing, hybrid Si nanocone/polymer solar cells are promising as an economically viable alternative energy solution. © 2012 American Chemical Society.

  10. Petrography and mineral chemistry of carbonatites and mica-rich rocks from the Araxá complex (Alto Paranaíba Province, Brazil

    Directory of Open Access Journals (Sweden)

    GIANBOSCO TRAVERSA

    2001-03-01

    Full Text Available The Araxá complex (16 km² comprises carbonatites forming a central core and a complex network of concentric and radial dykes as well as small veins; additionally, it includes mica-rich rocks, phoscorites and lamprophyres. Fenites also occur and are represented by Proterozoic quartzites and schists of the Araxá Group. The petrographic study of 130 borehole samples indicates that the complex is basically made up by two rock-types, carbonatites and mica-rich rocks, and subordinately by a third unit of hybrid composition. Carbonatites range chemically in composition, the most abundant type being magnesiocarbonatites. Dolomite and calcite correspond to the chief constituents, but other carbonate phases, including the Ce-group RE minerals, are also recognized. Phosphates and oxides are widespread accessories whereas silicate minerals consist of olivine, clinopyroxene, mica and amphibole. Mica-rich rocks are represented by abundant glimmeritic rocks and scarce cumulitic phlogopite-, olivine- and diopside-bearing pyroxenites. Hybrid rocks mainly contain phlogopite and tetraferriphlogopite as cumulus and intercumulus phases, respectively; carbonate minerals may also be found. Chemical data indicate that the carbonatites are strongly enriched in REE and have lower contents of Nb, Zr, V, Cr, Ni and Rb compared to the mica-rich rocks. The higher K, Nb and Zr contents of the latter rocks are believed to be related to metasomatic processes (glimmeritization of the pyroxenites. Similar REE patterns for carbonatites and mica-rich rocks seem to suggest that they are related to a single parental magma, possibly of ijolitic composition. Steep LREE/HREE fractionation and high sigmaREE content of some carbonatite samples would be explained by hydrothermal and supergenic processes.O complexo de Araxá (16 km² é constituído por carbonatitos na forma de um núcleo central e de complexa rede de diques concêntricos e radiais, além de pequenos veios

  11. Correlation between bulk- and surface chemistry of Cr-tanned leather and the release of Cr(III) and Cr(VI).

    Science.gov (United States)

    Hedberg, Yolanda S; Lidén, Carola; Odnevall Wallinder, Inger

    2014-09-15

    About 1-3% of the adult general population in Europe is allergic to chromium (Cr). The assessment of the potential release of Cr(III) and Cr(VI) from leather is hence important from a human health and environmental risk perspective. The Cr(VI) content in leather was recently restricted in the European Union. The aim of this study was to assess possible correlations between the bulk and surface chemistry of leather, released Cr(III) and Cr(VI), and capacities of co-released leather specific species to reduce and complex released Cr. Four differently tanned leathers were characterized by scanning electron microscopy with energy dispersive spectroscopy, X-ray photoelectron spectroscopy, attenuated total reflectance Fourier transform infrared (ATR-FTIR) spectroscopy, and the diphenylcarbazide colorimetric method. Their characteristics were compared with results on Cr(III) and Cr(VI) release into artificial sweat (ASW, pHleather-specific species were shown to reduce Cr(VI), both in ASW and in PB. Their reduction capacities correlated with findings of the surface content of Cr and of released Cr. Leather samples without this capacity, and with less aromatic surface groups visible by ATR-FTIR, revealed Cr(VI) both at the surface and in solution (PB). Copyright © 2014 The Authors. Published by Elsevier B.V. All rights reserved.

  12. Mujeres trabajadoras con dolor crónico osteomuscular: análisis de caso

    Directory of Open Access Journals (Sweden)

    Cecilia Andrea Ordóñez-Hernández

    2015-10-01

    Full Text Available Resumen El objetivo de este estudio fue conocer las experiencias de mujeres trabajadoras con dolor crónico osteomuscular. El diseño fue cualitativo con enfoque fenomenológico. La técnica utilizada fue entrevista en profundidad, realizada a cinco mujeres trabajadoras que consultaron por dolor osteomuscular mayor a 6 meses en los servicios de ortopedia y neurocirugía de un hospital en Guadalajara, México. Se encontró percepción de rechazo, segregación, discriminación y falta de apoyo en su ambiente laboral a causa de su dolor, y sentimientos de frustración e impotencia relacionados con su padecimiento de salud. Se percibe como barrera la mala percepción del personal de la salud y la falta de eficiencia en los procesos de incapacidad, reintegración y reubicación laboral. Las responsabilidades económicas y familiares son la principal motivación para continuar trabajando con la presencia de dolor osteomuscular crónico.

  13. Two-mica granites of northeastern Nevada.

    Science.gov (United States)

    Lee, D.E.; Kistler, R.W.; Friedman, I.; Van Loenen, R. E.

    1981-01-01

    The field settings are described and analytical data are presented for six two-mica granites from NE Nevada. High delta 18O and 87Sr/86Sr values indicate that all are S-type granite, derived from continental crust. The major element chemistry and accessory mineral contents of these rocks also are characteristic of S-type granites. Chemical, X ray, and other data are presented for the micas recovered from these granites. The muscovites are notably high in Fe2O3, FeO, and MgO. Except for one hydrobiotite, each of the biotites has an MgO content near 6.0 wt%. Two different types of two-mica granites are recognized in the area of this study. One type is distinguished by the presence of many biotite euhedra within muscovite phenocrysts and by an unusual suite of accessory minerals completely devoid of opaque oxides. This type probably resulted from anatexis of late Precambrian argillites under conditions of relatively low oxygen fugacity, along a line that roughly coincides with the westward disappearance of continental basement. In the other textural type of two-mica granite the micas are equigranular and there is a greater variety of accessory minerals. The magmatic evolution of this type also appears to reflect the influence of late Precambrian argillites; there may be age differences between the two types of two-mica granites.-Author

  14. Funções autonômica cardíaca e mecânica ventricular na cardiopatia chagásica crônica assintomática Cardiac autonomic and ventricular mechanical functions in asymptomatic chronic chagasic cardiomyopathy

    Directory of Open Access Journals (Sweden)

    Daniel França Vasconcelos

    2012-02-01

    Full Text Available FUNDAMENTO: A associação das funções autonômica cardíaca e ventricular sisto-diastólica variavelmente alteradas ainda é controversa e pouco explorada na cardiopatia chagásica crônica. OBJETIVO: Avaliar em que extensão as funções autonômica cardíaca e mecânica ventricular estão alteradas e se ambas estão relacionadas na cardiopatia chagásica assintomática. MÉTODOS: EM 13 cardiopatas chagásicos assintomáticos e 15 indivíduos normais (grupo controle, foram avaliadas e correlacionadas a modulação autonômica da variabilidade da frequência cardíaca durante cinco minutos, nos domínios temporal e espectral, nas posições supina e ortostática, e a função ventricular com base em variáveis morfofuncionais Doppler ecocardiográficas. A análise estatística empregou o teste de Mann-Whitney e a correlação de Spearman. RESULTADOS: Em ambas as posições, os índices temporais (p = 0,0004-0,01 e as áreas espectrais total (p = 0,0007-0,005 e absoluta, de baixa e alta frequências (p = 0,0001-0,002, mostraram-se menores no grupo chagásico. O balanço vagossimpático mostrou-se semelhante em ambas as posturas (p = 0,43-0,89. As variáveis ecocardiográficas não diferiram entre os grupos (p = 0,13-0,82, exceto o diâmetro sistólico final do ventrículo esquerdo que se mostrou maior (p = 0,04, correlacionando-se diretamente com os reduzidos índices da modulação autonômica global (p = 0,01-0,04 e parassimpática (p = 0,002-0,01, nos pacientes chagásicos, em posição ortostática. CONCLUSÃO: AS DEpressões simpática e parassimpática com balanço preservado associaram-se apenas a um indicador de disfunção ventricular. Isso sugere que a disfunção autonômica cardíaca pode preceder e ser independentemente mais severa que a disfunção ventricular, não havendo associação causal entre ambos os distúrbios na cardiopatia chagásica crônica.BACKGROUND: The association of variably altered cardiac autonomic and

  15. INFLUENCE OF ANNEALING ON HARDNESS OF Cr-Mn-Ni CAST IRONS

    Directory of Open Access Journals (Sweden)

    V. V. Netrebko

    2015-01-01

    Full Text Available The necessary level of material’s hardness is determined by the exploitation conditions and presence of technological operations during manufacturing of articles. Mechanical edge cutting machining of wear resistant materials is impeded because of their high hardness. It is recommended to apply annealing in order to decrease hardness and improve machinability. The purpose of the work consisted in obtaining of regression dependences of cast iron’s macrohardness on its chemical content after annealing at 730 °С. With the use of mathematical experimental design the regression dependences of cast iron’s macrohardness and structural components’ microhardness on С, Cr, Mn, Ni content have been established. The minimal hardness of 27,6 HRC after annealing at 730 °С is obtained in the cast iron containing: 3,9% С; 11,4% Cr; 0,6% Mn; 0,2% Ni. The maximal hardness of 70,4 HRC is obtained when the content is as follows: 1,1% С; 25,6% Cr; 5,4% Mn; 3,0% Ni. Annealing at 730 °С decreases the cast irons’ hardness containing the minimal amount of Cr, Mn and Ni. Annealing at 730 °С is recommended for cast irons alloyed by Mn and Ni for increasing of hardness.

  16. Análisis de la ira en pacientes con cardiopatía isquémica de la ciudad de Medellín (Colombia

    Directory of Open Access Journals (Sweden)

    Andrea Ochoa Ochoa

    2010-01-01

    Full Text Available Este estudio tuvo como objetivo comparar los niveles de ira, y sus componentes, entre un grupo de personas con Cardiopatía Isquémica y un grupo control sin esta enfermedad. Participaron 90 pacientes con cardiopatía isquémica de la Clínica Cardiovascular en Medellín y 78 controles sin la enfermedad. A cada uno de los participantes de les administró la prueba del STAXI- 2. Los resultados muestran que, comparado con los controles, los pacientes con cardiopatía isquémica tuvieron niveles significativamente más altos de ira como rasgo (p < 0.01, específicamente en la subescala reacción de ira (p < 0.05, y expresión interna de ira (p < 0.05. Los pacientes con cardiopatía isquémica experimentan más frecuentemente sentimientos de ira (ira rasgo, aparentemente debido a que son más sensibles a las críticas de los demás (reacción de ira, pero tienden a suprimir la expresión de esta emoción (expresión de ira interna. Estos datos confirman la necesidad de implementar programas dirigidos al manejo adecuado de la ira en estos pacientes y entender mejor las implicaciones que pueda tener la ira en la progresión de su enfermedad.

  17. Juicio crítico sobre un trabajo científico

    Directory of Open Access Journals (Sweden)

    Carlos Trujillo Gutiérrez

    1936-11-01

    Full Text Available El autor que usa el seudónimo Scribonius Largus se presenta al concurso  abierto por la Academia Nacional de Medicina para la adjudicación del Premio Manuel Forero en 1935, con la monografía titulada "El trabajo del corazón en Bogotá" (Introducción al estudio de la tensión arterial media dinámica en Colombia. Para dictaminar si este autor es acreedor al premio, debo hacer un estudio crítico, un análisis concienzudo de los hechos científicos y de la interpretación que el autor les da. En este sentido, seguiré fielmente el plan de trabajo que está compuesto de una introducción y de varios capítulos.

  18. Effect of Cr content on the SHS reaction of Cr-Ti-C system

    International Nuclear Information System (INIS)

    Zhang, W.N.; Wang, H.Y.; Wang, P.J.; Zhang, J.; He, L.; Jiang, Q.C.

    2008-01-01

    The effect of Cr content on the self-propagating high temperature synthesis (SHS) reaction of Cr-Ti-C system has been investigated in this research. The thermodynamics calculation indicates that the TiC possesses higher thermodynamic stability than the Cr 23 C 6 , Cr 7 C 3 and Cr 3 C 2 phases, and the formation of TiC is the most exothermic. Additionally, the adiabatic combustion temperature (T ad ) decreases with the increase of Cr content except for the phase transition regions. The XRD result shows that the type of products synthesized by SHS changes that a higher Cr content corresponds to higher chromium carbide. When Cr content is 10 wt.%, only solid solution (Ti,Cr)C ss is formed in the products. When Cr content increases to 20 wt.%, besides (Ti,Cr)C ss , the Cr 7 C 3 phase is also detected. With the Cr content further increasing to 30 and 40 wt.%, the products consist of (Ti,Cr)C ss , Cr 23 C 6 , Cr 7 C 3 and Cr, and therefore, much higher chromium carbide is synthesized. When Cr content reaches 50 wt.%, however, the Cr 7 C 3 disappears and the final products become (Ti,Cr)C ss , Cr 23 C 6 and Cr. Moreover, when Cr content increases from 10 to 20 wt.%, the lattice parameter of (Ti,Cr)C ss decreases, while it increases when the Cr content ranges from 20 to 50 wt.%. Furthermore, the microstructure shows that the TiC particulate size decreases from ∼8 to ∼2 μm with the increase of Cr content from 10 to 50 wt.%, and the morphology shape of TiC particulate becomes more and more spherical

  19. Formation of ω-phase in Zr-4 at.% Cr alloy

    International Nuclear Information System (INIS)

    Dobromyslov, A.V.; Kazantseva, N.V.

    1996-01-01

    The ω-phase has been discovered in zirconium-base alloys with the transition metals of Period 4 of the Periodic Table only in Zr-V, Zr-Cr, and Zr-Cu alloys. The first mention about the ω-phase formation in Zr-Cr alloys was given for Zr-4.5 at.%. However, there were no experimental data that confirmed this fact. W.M. Rumball and F.G. Elder presented the X-ray results on the ω-phase formation in Zr-3.9 at.%Cr, but at the present time there are no electron microscope studies of the structure of the ω-phase in this system. Investigations of the features of the ω-phase formation, morphology of the ω-phase and the mechanism of its formation in the different zirconium-base alloys are necessary to establish the common features of the formation of structures with the metastable phases. The task of the present work is to study the conditions and features of the ω-phase formation in the Zr-Cr alloys and the effect of the eutectoid decomposition on the formation of ω-phase. This article is part of the detailed investigations of the feature and condition of the ω-phase formation in zirconium-base alloys with the transition metals of the groups I and V to VIII of the Periodic Table

  20. Cuantificación de plomo, cadmio y cromo mediante sialoquímica

    Directory of Open Access Journals (Sweden)

    GONZÁLEZ MIREYA

    1997-01-01

    Full Text Available Objetivo. Determinar las concentraciones de plomo, cadmio y cromo, y establecer su posible asociación con diferentes factores sociodemográficos. Material y métodos. Se seleccionó una muestra representativa de 100 estudiantes de posgrado de la Facultad de Odontología de la Universidad Nacional Autónoma de México (UNAM, a los cuales se les colectó saliva total no estimulada. Dichas muestras fueron analizadas por espectrofotometría de absorción atómica con horno de grafito. Resultados. Metales pesados como el plomo, el cadmio y el cromo se encuentran en concentraciones mucho más altas que las informadas en la literatura: Pb, = 3.10 m g/dL-1, máxima: 16.8 my g/dL-1, y mínima: 0.04 my g/dL-1; Cd, = 0.25 my g/dL-1, máxima: 2.04 my g/dL-1, y mínima: 0.004 my g/dL-1; y Cr, = 1.43 my g/dL-1, máxima: 4.82 my g/dL-1, y mínima: 0.05 my g/dL-1. Asimismo, variables como la zona de residencia, el sexo, la edad y la ingesta de comida enlatada no influyen en los niveles de plomo y cromo. Sin embargo, en el caso del cadmio y la edad existe una asociación inversa (ji²= 5.9012, p<= 0.05; gamma = -0.5224, p<= 0.05. Conclusiones. La sialoquímica juega un papel importante en la detección de contaminantes, fármacos, drogas y enfermedades locales y sistémicas. La contaminación por metales pesados sigue siendo un problema de salud pública, por lo que el gobierno debe consolidar un programa cuyo objetivo sea eliminar los diferentes contaminantes del ambiente. Asimismo, se deben realizar otros estudios para verificar la asociación de variables como sexo, edad, uso de cerámica vidriada, alimentación y zona de residencia con las concentraciones de metales pesados en saliva.

  1. Polymer/surfactant assisted self-assembly of nanoparticles into Langmuir–Blodgett films

    International Nuclear Information System (INIS)

    Alejo, T.; Merchán, M.D.; Velázquez, M.M.; Pérez-Hernández, J.A.

    2013-01-01

    We studied the ability of poly(octadecene-co-maleic anhydride) (PMAO) and a Gemini surfactant [C 18 H 37 (CH 3 ) 2 N + Br − –(CH 2 ) 2 –N + Br − (CH 3 ) 2 C 18 H 37 ] (18-2-18) to assist in the self-assembly process of CdSe quantum dots (QDs) at the air–water interface. Results show that, while QD agglomeration is generally inhibited by the addition of these components to the Langmuir monolayer of QDs, structure of the film transferred onto mica by the Langmuir–Blodgett method is strongly affected by the dewetting process. Nucleation-and-growth of holes and spinodal-like dewetting were respectively observed in the presence of either PMAO or 18-2-18. When PMAO/18-2-18 mixtures were used, both mechanisms were allowed; nevertheless, even in films prepared with mixtures of low polymer contents, characteristic morphology from the polymer dewetting route prevailed. Highlights: ► Effect of the composition on the LB films of QDs/polymer. ► Effect of the composition on the LB films of QDs/Gemini surfactant. ► Dewetting mechanisms

  2. 40Ar/39Ar Dating of Zn-Pb-Ag Mineralization in the Northern Brooks Range, Alaska

    Science.gov (United States)

    Werdon, Melanie B.; Layer, Paul W.; Newberry, Rainer J.

    2004-01-01

    The 40Ar/39Ar laser step-heating method potentially can be used to provide absolute ages for a number of formerly undatable, low-temperature ore deposits. This study demonstrates the use of this method by determining absolute ages for Zn-Pb-Ag sediment-hosted massive sulfide deposits and vein-breccia occurrences found throughout a 300-km-long, east-west-trending belt in the northern Brooks Range, Alaska. Massive sulfide deposits are hosted by Mississippian to Pennsylvanian(?) black carbonaceous shale, siliceous mudstone, and lesser chert and carbonate turbidites of the Kuna Formation (e.g., Red Dog, Anarraaq, Lik (Su), and Drenchwater). The vein-breccia occurrences (e.g., Husky, Story Creek, West Kivliktort Mountain, Vidlee, and Kady) are hosted by a deformed but only weakly metamorphosed package of Upper Devonian to Lower Mississippian mixed continental and marine clastic rocks (the Endicott Group) that stratigraphically underlie the Kuna Formation. The vein-breccias are mineralogically similar to, but not spatially associated with, known massive sulfide deposits. The region's largest shale-hosted massive sulfide deposit is Red Dog; it has reserves of 148 Mt grading 16.6 percent zinc, 4.5 percent lead, and 77 g of silver per tonne. Hydrothermally produced white mica in a whole-rock sample from a sulfide-bearing igneous sill within the Red Dog deposit yielded a plateau age of 314.5 Ma. The plateau age of this whole-rock sample records the time at which temperatures cooled below the argon closure temperature of the white mica and is interpreted to represent the minimum age limit for massive sulfide-related hydrothermal activity in the Red Dog deposit. Sulfide-bearing quartz veins at Drenchwater crosscut a hypabyssal intrusion with a maximum biotite age of 337.0 Ma. Despite relatively low sulfide deposition temperatures in the vein-breccia occurrences (162°-251°C), detrital white mica in sandstone immediately adjacent to large vein-breccia zones was partially to

  3. Measurement of D-3He proton yield with CR-39 as a diagnostic for inertial confinement fusion experiments. Final report, 7 January 1983-30 September 1984

    International Nuclear Information System (INIS)

    Blue, T.E.; Wehring, B.W.

    1985-04-01

    The first phase of our research project has as its main goal the development of an image analysis system for Solid State Nuclear Track Detectors (SSNTD) readout. Section I, of this report is an introduction to SSNTDs and image analysis systems for automatic track counting. The development of the image analysis system is described in Section II. The development of our foil holder system is described in Section III. The performance of an image analysis system can only be judged with respect to a particular type of image which is to be analyzed. In order to insure the workability of our image analysis system in analyzing CR-39 SSNTDs, we have made an effort to improve our etching system and our etch procedure. The development of our etching system and our etch procedure is outlined in Section IV. Also included in Section IV are images of protons and alpha particle tracks for our etch procedure. The performance of our image analysis system is reported in Section V for the proton and alpha particle tracks which are reported in Section IV. Also, the performance of the image analysis system is reported for some test images

  4. Effect of Post Treatment For Cu-Cr Source/Drain Electrodes on a-IGZO TFTs.

    Science.gov (United States)

    Hu, Shiben; Fang, Zhiqiang; Ning, Honglong; Tao, Ruiqiang; Liu, Xianzhe; Zeng, Yong; Yao, Rihui; Huang, Fuxiang; Li, Zhengcao; Xu, Miao; Wang, Lei; Lan, Linfeng; Peng, Junbiao

    2016-07-27

    We report a high-performance amorphous Indium-Gallium-Zinc-Oxide (a-IGZO) thin-film transistor (TFT) with new copper-chromium (Cu-Cr) alloy source/drain electrodes. The TFT shows a high mobility of 39.4 cm 2 ·V - 1 ·s - 1 a turn-on voltage of -0.8 V and a low subthreshold swing of 0.47 V/decade. Cu diffusion is suppressed because pre-annealing can protect a-IGZO from damage during the electrode sputtering and reduce the copper diffusion paths by making film denser. Due to the interaction of Cr with a-IGZO, the carrier concentration of a-IGZO, which is responsible for high mobility, rises.

  5. Eletrencefalograma antes e após hemodiálise, diálise peritoneal e transplante renal: estudo de correlações da atividade de fundo com a bioquímica plasmática

    Directory of Open Access Journals (Sweden)

    Luiz Antonio de Lima Resende

    1987-09-01

    Full Text Available Estudamos as correlações entre atividade de fundo no EEG e anormalidades bioquímicas do plasma em 49 pacientes com insuficiência renal crônica. Foi realizado estudo do EEG e bioquímico antes e após hemodiálise em 20 pacientes, antes e após diálise peritoneal em 14 e antes e após transplante renal em 15 pacientes. Observamos piora do EEG após hemodiálise e diálise peritoneal e melhora do EEG após transplante, sugerindo que em nossos pacientes as alterações da atividade de fundo induzidas pela uremia crônica eram reversíveis. Com base em nossos resultados, consideramos difícil estabelecer correlações entre o EEG e alterações da bioquímica plasmática. Entretanto, há correlação estatística entre hipernatremia, melhora da acidose metabólica, aumento da relação zinco/cobre e piora da atividade de fundo no EEG.

  6. Preliminary Microstructural and Microscratch Results of Ni-Cr-Fe and Cr3C2-NiCr Coatings on Magnesium Substrate

    Science.gov (United States)

    Istrate, B.; Munteanu, C.; Lupescu, S.; Benchea, M.; Vizureanu, P.

    2017-06-01

    Thermal coatings have a large scale application in aerospace and automotive field, as barriers improving wear mechanical characteristics and corrosion resistance. In present research, there have been used two types of coatings, Ni-Cr-Fe, respectively Cr3C2-NiCr which were deposited on magnesium based alloys (pure magnesium and Mg-30Y master alloy). There have been investigated the microstructural aspects through scanning electronic microscopy and XRD analysis and also a series of mechanical characteristics through microscratch and indentation determinations. The results revealed the formation of some adherent layers resistant to the penetration of the metallic indenter, the coatings did not suffer major damages. Microstructural analysis highlighted the formation of Cr3C2, Cr7C3, Cr3Ni2, Cr7Ni3, FeNi3, Cr-Ni phases. Also, the apparent coefficient of friction for Ni-Cr-Fe coatings presents superior values than Cr3C2-NiCr coatings.

  7. La escritura académica como proceso epistémico en la enseñanza del derecho penal

    Directory of Open Access Journals (Sweden)

    Caviedes Estanislao Escalante-Barreto

    2015-05-01

    Full Text Available La superación de concepciones pedagógicas basadas en modelos conductistas y la implementación de otras formas metodológicas pueden llevar al "aprendizaje crítico natural". Este es un escenario propicio para generar nuevas formas de construir conocimiento, considerando a los partícipes del acto educativo como sujetos de interacción pedagógica. Este contexto permite identificar la escritura y la alfabetización académica como procesos epistemológicos de construcción y transformación del conocimiento penal. Por lo que se plantea como reto la necesidad de reconocer que la escritura es un proceso que se construye de manera permanente por comunidades académicas y no por individuos aislados. Este proceso se caracteriza por permitir la construcción de conocimiento nuevo, reflexivo y analítico en el aprendizaje/enseñanza, el cual debe ser reconocido como parte del proceso pedagógico y de reflexión sobre el acto educativo para transformar la enseñanza del derecho penal.

  8. La coyuntura económica nacional

    Directory of Open Access Journals (Sweden)

    Arturo Huerta González

    2003-01-01

    Full Text Available El objetivo de este artículo es analizar los problemas de contracción económica que enfrenta nuestro país como resultado de la política económica predominante, que lo ha llevado a depender de la economía estadounidense. Cuando ésta enfrentó problemas de crecimiento también frenó el crecimiento de la economía nacional. El gobierno mexicano no instrumenta política fiscal anticíclica (expansión del gasto para contrarrestar la caída de exportaciones y recuperar la dinámica económica por considerar que ello originaría presiones sobre precios y el sector externo y pudiera llevar a un contexto de especulación y crisis. Es por esto que se opta por seguir priorizando políticas contraccionistas para evitar la inflación, como si éste fuese el principal problema del país. Asimismo, el gobierno insiste en las reformas estructurales (apertura eléctrica, petrolera, reforma fiscal y laboral para ampliar la esfera de influencia del sector privado nacional y extranjero y para consolidar el saneamiento fiscal y abaratar el costo de la fuerza de trabajo, impulsando así la dinámica económica. Sin embargo, tales reformas ya las hemos vivido —desde el gobierno de Salinas de Gortari a la fecha— y sus resultados han sido crecimientos espurios que han desembocado en crisis y en el actual estancamiento. Mientras prosiga la actual política económica seguirá deteriorándose la esfera productiva y aumentando el desempleo, sin que se logre un crecimiento sostenido y menos vulnerable de la economía

  9. Cr{sub 2}O{sub 5} as new cathode for rechargeable sodium ion batteries

    Energy Technology Data Exchange (ETDEWEB)

    Feng, Xu-Yong; Chien, Po-Hsiu; Rose, Alyssa M.; Zheng, Jin [Department of Chemistry and Biochemistry, Florida State University, Tallahassee, FL 32306 (United States); Hung, Ivan; Gan, Zhehong [Centre of Interdisciplinary Magnetic Resonance, National High Magnetic Field Laboratory, 1800 East Paul Dirac Drive, Tallahassee, FL 32310 (United States); Hu, Yan-Yan, E-mail: hu@chem.fsu.edu [Department of Chemistry and Biochemistry, Florida State University, Tallahassee, FL 32306 (United States); Centre of Interdisciplinary Magnetic Resonance, National High Magnetic Field Laboratory, 1800 East Paul Dirac Drive, Tallahassee, FL 32310 (United States)

    2016-10-15

    Chromium oxide, Cr{sub 2}O{sub 5}, was synthesized by pyrolyzing CrO{sub 3} at 350 °C and employed as a new cathode in rechargeable sodium ion batteries. Cr{sub 2}O{sub 5}/Na rechargeable batteries delivered high specific capacities up to 310 mAh/g at a current density of C/16 (or 20 mA/g). High-resolution solid-state {sup 23}Na NMR both qualitatively and quantitatively revealed the reversible intercalation of Na ions into the bulk electrode and participation of Na ions in the formation of the solid-electrolyte interphase largely at low potentials. Amorphization of the electrode structure occurred during the first discharge revealed by both NMR and X-ray diffraction data. CrO{sub 3}-catalyzed electrolyte degradation and loss in electronic conductivity led to gradual capacity fading. The specific capacity stabilized at >120 mAh/g after 50 charge-discharge cycles. Further improvement in electrochemical performance is possible via electrode surface modification, polymer binder incorporation, or designs of new morphologies. - Graphical abstract: Electrochemical profile of a Cr{sub 2}O{sub 5}/Na battery cell and high-resolution solid-state {sup 23}Na MAS NMR spectrum of a Cr{sub 2}O{sub 5} electrode discharged to 2 V. - Highlights: • Cr{sub 2}O{sub 5} was synthesized and used as a new cathode in rechargeable Na ion batteries. • A high capacity of 310 mAh/g and an energy density of 564 Wh/kg were achieved. • High-resolution solid-state {sup 23}Na NMR was employed to follow the reaction mechanisms.

  10. Microwave synthesis: An alternative approach to synthesize conducting end-capped polymers

    Czech Academy of Sciences Publication Activity Database

    Marcasuzaa, P.; Reynaud, S.; Grassl, B.; Preud’homme, H.; Desbrieres, J.; Trchová, Miroslava; Donard, O. F. X.

    2011-01-01

    Roč. 52, č. 1 (2011), s. 33-39 ISSN 0032-3861 Grant - others:Eco-net project (FR) 16256SA Institutional research plan: CEZ:AV0Z40500505 Keywords : tetra-aniline * microwave synthesis * intrinsically conducting polymers Subject RIV: CD - Macromolecular Chemistry Impact factor: 3.438, year: 2011

  11. QUÍMICA VERDE: UN NUEVO RETO

    Directory of Open Access Journals (Sweden)

    Nerlis Paola Pájaro Castro

    2011-01-01

    Full Text Available En la actualidad, existe un enorme deterioro del medio ambiente que ha generado la necesidad de buscar alternativas que conduzcan a la sostenibilidad ambiental. Una de estas herramientas es la ¿química verde¿, concepto que contempla el diseño de productos y procesos que reduzcan la generación de sustancias peligrosas y maximicen la eficiencia en la utilización de recursos materiales y energéticos. El empleo de tecnologías menos contaminantes, permitirá a las empresas químicas mitigar los efectos ambientales asociados a su actividad, reduciendo el consumo de materiales e incrementando la participación de recursos renovables. Para alcanzar estas metas, se han propuesto 12 principios básicos de química verde, aplicables en diferentes campos, tales como la medicina, la agricultura, la industria química y farmacéutica. Esta revisión detalla los principios y usos principales de la química verde, y su aplicación como una filosofía de trabajo para avanzar hacia un verdadero desarrollo sostenible.

  12. Implementación de la estrategia didáctica del desarrollo del pensamiento crítico-reflexivo en el análisis literario de Hamlet de Shakespeare

    Directory of Open Access Journals (Sweden)

    Norman Marín-Calderón

    2014-01-01

    Full Text Available Este ensayo se concentra en el proceso de ejecución del desarrollo del pensamiento crítico- reflexivo como una estrategia didáctica universitaria en la enseñanza de una clase de literatura, más específicamente, de la obra de William Shakespeare, Hamlet (1603. Dicha estrategia se basó en una serie de actividades comunicativas que se propusieron observar el desarrollo de las habilidades cognitivas, el proceso de crítica y análisis, la reflexión personal a través de experiencias vivenciales, así como el desarrollo de técnicas de argumentación y pensamiento crítico de los estudiantes. El propósito en la implementación de la estrategia fue la de potenciar la calidad académica de las producciones críticas y argumentativas de los estudiantes, al momento de analizar Hamlet en tanto texto literario.

  13. MICA: Multiple interval-based curve alignment

    Science.gov (United States)

    Mann, Martin; Kahle, Hans-Peter; Beck, Matthias; Bender, Bela Johannes; Spiecker, Heinrich; Backofen, Rolf

    2018-01-01

    MICA enables the automatic synchronization of discrete data curves. To this end, characteristic points of the curves' shapes are identified. These landmarks are used within a heuristic curve registration approach to align profile pairs by mapping similar characteristics onto each other. In combination with a progressive alignment scheme, this enables the computation of multiple curve alignments. Multiple curve alignments are needed to derive meaningful representative consensus data of measured time or data series. MICA was already successfully applied to generate representative profiles of tree growth data based on intra-annual wood density profiles or cell formation data. The MICA package provides a command-line and graphical user interface. The R interface enables the direct embedding of multiple curve alignment computation into larger analyses pipelines. Source code, binaries and documentation are freely available at https://github.com/BackofenLab/MICA

  14. Ensayo sobre endurecimiento de adhesivos estructurales sometidos a cargas dinámicas

    Directory of Open Access Journals (Sweden)

    Recuero, A.

    2004-04-01

    Full Text Available Carbon fibre reinforced polymers are increasingly replacing the steel reinforcing systems in the repair and strengthening of concrete structures thanks to their high strength/weight and stiffness/weight ratios, corrosion resistance, lightweight, and ease of handling and application. This paper presents a study on the behaviour of bridge concrete beams strengthened with CFRP sheets when the strengthening is made when traffic is acting so that the structure is subjected to dynamic loads while the adhesive is still fresh. No reduction in the effectiveness of the strengthening was observed in the tests.

    Los polímeros reforzados con fibras de carbono se están utilizando cada vez más para el refuerzo de estructuras de hormigón, reemplazando a los sistemas tradicionales de refuerzo con acero. Esto es debido a sus altas resistencia y rigidez específicas, resistencia a la corrosión, ligereza y facilidad de manejo y puesta en obra. Este artículo presenta un estudio sobre el comportamiento de vigas de puentes reforzadas con bandas de CFRP mientras se mantiene el puente en servicio de manera que la estructura está sometida a cargas dinámicas con el adhesivo fresco. En los ensayos realizados se ha observado que las cargas dinámicas no afectan a la efectividad del refuerzo.

  15. Algoritmos para genómica comparativa

    OpenAIRE

    Figueiras, Vasco da Rocha

    2010-01-01

    Com o surgimento da Genómica e da Proteómica, a Bioinformática conduziu a alguns dos avanços científicos mais relevantes do século XX. A Unidade de Investigação e Desenvolvimento do Biocant, parque biotecnológico de Cantanhede, assume actualmente o papel de motor no desenvolvimento da Genómica. O Biocant possui um importante sequenciador de larga escala que permite armazenar um elevado número de genomas, nomeadamente, genomas de bactérias. O estudo proposto reflecte a necessidade do Bio...

  16. Análisis de la degradación de recubrimientos de barrera térmica por espectroscopía de impedancia electroquímica

    Directory of Open Access Journals (Sweden)

    Gómez-García, J.

    2007-10-01

    Full Text Available This investigation correlates the microstructure of a thermal barrier coating, analysed through scanning electron microscopy and X-ray microanalysis, with the electrochemical impedance spectroscopy data which show the variation in electrical properties after isothermal oxidation. A thermal barrier coating comprising a ceramic top layer, ZrO2 8Y2O3 (weight %, and an overlay coating, Ni 22Cr 10Al 1Y (weight %, air plasma sprayed over a nickel base alloy In 600 substrate was studied. These materials were heat treated in air at 1050 ºC for 72, 144 y 336 h. A thermally grown oxide layer, mainly comprising Cr y Al oxides, was formed between the ceramic and the overlay coating. This layer modified the electrical response of the thermal barrier coating in the electrochemical impedance spectroscopy tests.

    Este trabajo correlaciona la microestructura de un recubrimiento de barrera térmica, estudiada mediante microscopía electrónica de barrido y microanálisis de rayos X, con los resultados obtenidos mediante espectroscopía de impedancia electroquímica que muestran la variación de sus propiedades eléctricas tras un proceso de oxidación isoterma. El sistema estudiado está formado por una capa cerámica, ZrO2 8Y2O3 (% en masa, y un anclaje metálico, Ni 22Cr 10Al 1Y (% en masa, depositados ambos por proyección térmica asistida por plasma sobre un sustrato de aleación base níquel In 600. Estos recubrimientos se oxidaron isotérmicamente en aire a 1050 ºC durante 72, 144 y 336 h. Se formó una capa intermedia de óxidos (“thermally grown oxides”, TGO entre el anclaje metálico y el recubrimiento cerámico formada por una mezcla de óxidos de Cr y Al que se tradujo en la variación de los parámetros característicos de la impedancia de la barrera térmica.

  17. CO2 Conversion: The Potential of Porous–Organic Polymers (POPs) for the cycloaddition of CO2 and epoxides

    KAUST Repository

    Alkordi, Mohamed Helmi

    2016-03-30

    Novel porous organic polymers (POPs) have been synthesized using functionalized Cr and Co-salen complexes as molecular building blocks. The integration of metalosalen catalysts into the porous polymers backbone permits the successful utilization of the materials as solid-state catalysts for CO2-epoxide cycloadditions reactions with excellent catalytic performance under mild conditions of temperature and pressure. The catalyst proved to be fully recyclable and robust thus showing the potential of POPs as smart functional materials for the heterogenization of key catalytic elements.

  18. Cross section of ternary fission of Al, Ti, Co and Zr nuclei induced by 0,8 - 1,8 Gev photons

    International Nuclear Information System (INIS)

    Lima, D.A. de; Sousa, E.V. de; Milomen, W.C.C.; Tavares, O.A.P.

    1988-01-01

    A research on ternary fission of Al, Ti, Co, and Zr nuclei induced by bremsstrahlung photons of 0,8, 1,0, 1,4, and 1,8 Gev end-point energies has been carried out using makrofol polycarbonate and CR-39 polymer as fission-track detectors. Results are discussed and compared with other ternary fission data. (M.W.O.) [pt

  19. RIGScan CR: RIGScan CR49.

    Science.gov (United States)

    2004-01-01

    RIGScan CR49, a 125I-labelled CR monoclonal antibody directed against the tumour-associated antigen TAG-72, is undergoing development with Neoprobe for the intraoperative detection of metastatic colorectal cancer. The Neoprobe's proprietary RIGS (radioimmunoguided surgery) technology combines an injectable radiolabelled cancer-targeting agent and hand-held radiation detection probe that emits an audible tone when located tissue has accumulated a significant amount of the radioactive agent. Neoprobe's RIGS technology also includes a patented surgical method providing surgeons with real-time information to locate tumour deposits that can not be detected by other conventional methods. The RIGS technology has been evaluated in late clinical studies for the detection of adenocarcinomas including primary colorectal, gastrointestinal, breast, ovarian, pancreatic, prostate and neuroendocrine/endocrine. Neoprobe signed an option agreement for its first-generation RIGScan compound, RIGScan CR, with OncoSurg Inc. (formerly NuRigs Ltd). The second-generation humanised RIGScan CR agent was also optionally licensed to OncoSurg Inc. In 1997, Neoprobe filed for approval with the US FDA and the EMEA for RIGScan CR for the intraoperative detection of metastatic colorectal cancer. Both regulatory agencies have requested additional clinical data. On 19 April 2004, Neoprobe announced that it had met with the US FDA to discuss its position on submitting additional clinical information in response to the FDA's questions regarding the Biologic Licence Application (BLA) for RIGScan CR49. The company provided the FDA with new information related to a survival differential for patients whose colorectal cancer was evaluated with RIGScan CR49. The information was not available at the time of the BLA's submission in 1997. The agency indicated that it would consider accepting survival data from one of the two phase III trials, NEO2-14, but not from another trial NEO2-13, as supportive data for a

  20. Abordajes endoscópicos a la base de cráneo anterior

    Directory of Open Access Journals (Sweden)

    Gonzalo De Los Santos

    2016-07-01

    Full Text Available Los abordajes endoscópicos a la base de cráneo anterior se han desarrollado de forma muy importante en las últimas décadas y continúan extendiéndose paralelamente a la aparición de nuevo instrumental y equipo que facilitan su aplicación. Factores importantes que han contribuido a ello son la posibilidad de acceder de forma directa a zonas difíciles y la disminución de morbilidad que pueden aportar, manteniendo los resultados esperados. Pero también tienen desventajas y limitaciones pues requieren conocimiento anatómico y el uso de material específico en un campo quirúrgico limitado por el espacio, estructuras anatómicas vitales y la visión bidimensional. La correcta planificación quirúrgica y la selección de los pacientes son elementos fundamentales. Esto nos permitirá determinar si es posible este tipo de abordaje, conocer la localización de la lesión, la zona de entrada al cráneo y el corredor que deberemos utilizar para ello. Los abordajes endoscópicos, correctamente indicados y planificados son procedimientos seguros y efectivos.