WorldWideScience

Sample records for mica cr-39 polymer

  1. Alkaline erosion of CR 39 polymer surfaces

    International Nuclear Information System (INIS)

    Faiman, Laurence

    2009-01-01

    We have investigated the mechanism of erosion of CR 39 polymer in alkaline environments. We observed the kinetics of absorption of water and methanol into both unirradiated and γ-irradiated samples. We use a capillary model to interpret our results. We etched our samples in both KOH solutions, and KOH solutions doped with methanol. Etch rate was desensitizing to γ-irradiation when KOH concentration approached saturation, but KOH solutions doped with methanol were not desensitizing, unlike with nuclear tracks. We account for this difference

  2. Thermal degradation of CR-39 polymer in an inert atmosphere

    International Nuclear Information System (INIS)

    Kalsi, P.C.; Pandey, A.K.; Iyer, R.H.; Singh Mudher, K.D.

    1995-01-01

    The thermal degradation of CR-39 (allyl diglycol carbonate), a polymer widely used in nuclear science and technology, in an inert atmosphere has been studied using thermogravimetric analysis (TGA) and differential thermal analysis (DTA) techniques. The results are compared with the thermal degradation data of the polymer in an air atmosphere. The present studies showed that the thermal degradation of the polymer proceeds in two steps in an argon atmosphere as compared to three steps in air atmosphere. The mass losses in air are higher than that in argon due to the oxidative decomposition of the residue. The kinetics of the different stages of degradation were also evaluated from the TG curves. (author). 7 refs., 1 tab

  3. Electrochemical development of particle tracks in CR-39 polymer dosimeter

    International Nuclear Information System (INIS)

    Hadlock, D.E.; Parkhurst, M.A.; Yang, C.S.; Groeger, J.; Johnson, J.R.; Huang, S.J.

    1985-09-01

    Electrochemical etching of CR-39 polymeric track etch neutron detectors results in proton-recoil tracks can be distinguished from background tracks much better than tracks developed solely by chemical etching. A newly designed and constructed electrochemical etching apparatus allows large numbers of dosimeters to be processed simultaneously with consistent results. Many processing systems have been developed for chemical and electrochemical etching of the track etch dosimeters. Three systems specifically show great promise and are being studied extensively

  4. Radon diffusion in polymer vessels using CR-39 solid state nuclear track detector

    Energy Technology Data Exchange (ETDEWEB)

    Carneiro, Andre Cavalcanti; Menezes, Maria Angela de B.C.; Rocha, Zildete; Pereira, Marcio Tadeu, E-mail: andreccarneiro@gmail.com, E-mail: menezes@cdtn.br, E-mail: zildete@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Santos, Talita de Oliveira; Lara, Evelise Gomes; Braga, Mario Roberto Martins S.S., E-mail: mariomartins@gmail.com, E-mail: evelise.lara@gmail.com, E-mail: talitaolsantos@yahoo.com.br [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil)

    2015-07-01

    At CDTN/CNEN, the method to determine {sup 226}Ra in several matrices by gamma spectrometry is already established; however, the method should be improved. This paper is about the first step of this improvement. Several polymer vessels were studied verifying the effect of radiolysis on the walls of the vessel. A test about the diffusion of {sup 222}Rn through the walls was carried out using the CR-39 solid state nuclear track detector. The results pointed out that the vessel made up by acrylic material is the best candidate to replace the vessel actually used. (author)

  5. Characteristics of latent damage trails due to high energy 208Pb and 238U ions in CR-39 and muscovite mica

    International Nuclear Information System (INIS)

    Chohan, A.S.; Akhtar, S.M.

    1988-01-01

    Experiments have been performed to study the characteristics of latent damage trails produced by (a) 17.14 MeV/nucleon- 208 Pb ions in mica and CR-39 track detectors and (b) 13.7 MeV/nucleon- 238 U in CR-39 track detectors. The parameters studied include (a) V t , average etching velocity along the track, (b) thermal stability of the latent damage trails, (c) the total etchable ranges, and (d) V g the general etching velocity of CR-39 track detectors previously annealed at different temperatures. It has been observed that the latent damage trails in CR-39 are greatly affected at temperatures around 200 0 C in CR-39 track detectors. The general etching velocity of a CR-39 detector has been found to increase with increasing annealing temperatures. (author)

  6. Sensitivity of chemically and electrochemically etched CR 39 polymers to the neutrons of AmBe source

    International Nuclear Information System (INIS)

    Turek, K.; Spurny, F.; Dajko, G.; Somogyi, G.

    1981-01-01

    Seven samples of polymers by different manufacturers were used in a study of the sensitivity of CR 39 polymers to Am-Be neutrons. In the polymer, proton tracks for a relatively broad energy range can also be recorded. The following characteristics were studied: the sample background for different etching methods, the dependence of sensitivity on the etched thickness and on neutron fluence, the effect of type and thickness of external proton emitters, and the effect of the choice of electric parameters on the resulting sensitivity in electrochemical etching. Good results were obtained when chemical and electrochemical etching was used in combination. It was found that with electrochemical etching, sensitivity decreases for neutron fluence exceeding 10 8 cm -2 . The sensitivity of the studied CR 39 polymer samples only little differed. When the most sensitive polymer was used, the minimum dose equivalent in the human body for Am-Be neutrons which could be determined using combination etching was 0.4 mSv (ie., 40 mrems). (B.S.)

  7. Studies of isothermal annealing of fission fragment and alpha particle tracks in Cr-39 polymer detectors

    International Nuclear Information System (INIS)

    Zaky, M.F.; Youssef, A.A.

    2002-01-01

    Two groups of CR-39 detectors samples are exposed to two types of charged particle radiation. The first group are severe damaged with fission fragment tracks from 2 52C f source. The second accepted alpha particles resulting from the interaction of highly energetic 1 9F -ions and a copper disk with thickness 1 cm, which are of less damage tracks than fission fragments. , The isothermal annealing of tracks in the temperature range from 175 to 300 degree C in step 25 degree C for annealing time of 10,15,20,25 and 30 minutes has been investigated. The changes introduced in the track density and track diameter for two types of irradiation in the detector have been observed and compared between them. The results indicate that the track density and the size of the tracks are considerably changed due to annealing

  8. Study of the optical properties and the carbonaceous clusters in thermally-annealed CR-39 and Makrofol-E polymer-based solid-state nuclear track detectors

    International Nuclear Information System (INIS)

    El Ghazaly, M.

    2012-01-01

    The induced modifications in the optical properties of CR-39 and Makrofol-E polymer-based solid state nuclear track detectors were investigated after thermal annealing at a temperature of 200 .deg. C for different durations. The optical properties were studied using an UV-visible spectrophotometer. From the UV-visible spectra, the direct and the indirect optical band gaps, Urbach's energies, and the number of carbon atoms in a cluster were determined. The absorbance of CR-39 plastic detector was found to decrease with increasing annealing time while the absorbance of Makrofol-E decreased with increasing annealing time. The width of the tail of localized states in the band gap ΔE was evaluated with the Urbach method. The optical energy band gaps were obtained from the direct and the indirect allowed transitions in K-space. Both of the direct and the indirect band gaps of the annealed CR-39 detector decrease with increasing annealing time while in Makrofol-E, they decreased after an annealing time of 15 minute and then showed no remarkable changes for a prolonged annealing times. Urbach's energy decreased significantly for both CR-39 and Makrofol-E with increasing annealing time. The number of carbon atoms in a cluster increased in the CR-39 detector with increasing annealing time while it decreased with increasing annealing time for Makrofol-E. We may conclude that the CR-39 detector undergoes greater modifications than the Makrofol-E detector upon thermal annealing at 200 .deg. C. In conclusion, the induced modifications in the optical properties of CR-39 and Makrofol-E are correlated with the temperature and the duration of annealing.

  9. Neutron dosimeter utilizing CR-39

    International Nuclear Information System (INIS)

    Souza, H.V.C. de.

    1991-05-01

    A personnel neutron dosimeter has been developed with discretization in a wide range of energies of real interest, utilizing the CR-39 polymer, to detect recoil protons in the fast range, and alpha particles in the thermal and epithermal ranges, with possibility to be disposed in the IRD/CNEN's conventional film badge suport. They are presented, abstractly, the difficulties and importance of the neutron dosimetry, beyond the general objectives that motivated this work execution. The details of the materials utilized in the dosimeter confection, and the experimental methodology employed to obtain the performance curves are presented. The results about linearity response of the dosimeter with respect to equivalent dose, in a wide range of doses, and about the verified angular dependence are analysed. (author)

  10. Is CR39 worth the effort?

    International Nuclear Information System (INIS)

    Griffith, R.V.

    1987-01-01

    CR39 proton sensitive track detectors were greeted by the radiation protection community at the end of the last decade as a major breakthrough for personnel neutron dosimetry. A number of laboratories eagerly began research on application of CR39 to their dosimetry needs. However, in the last two or three years the enthusiasm has subsided, and many health physicists have stopped working with the material. The number of participants using CR39 in the Oak Ridge National Laboratory Personnel Intercomparison Studies dropped from six in 1985 to three in 1986. On a national level, the Federal Republic of Germany with researchers active in CR39 research recently adopted an albedo system as their national standard. In contrast, the United States Department of Energy (DOE) is supporting development of a CR39 based combination dosimeter to meet Department wide dosimetry needs. The English National Radiological Protection Board (NRPB) now features the use of CR39 in the NRPB PADC(CR39). There has obviously been a range of experiences with CR39 in the dosimetry community. Why has this been the case, and what is the proper role for CR39 in personnel neutron dosimetry. 12 refs., 2 figs., 1 tab

  11. A study of the molecular structure in CR-39

    International Nuclear Information System (INIS)

    Stejny, J.; Portwood, T.

    1986-01-01

    A technique is presented for examining the molecular structure of CR-39 by analysis of the etch products from hydrolysis of the polymer network. The CR-39 network consists of polyallyl chains jointed by diethyleneglycol dicarbonate links. The etching cuts the carbonate links and liberates the polyallyl chains which makes them amenable to common analytical methods. Gel Permeation Chromatography was used to characterize the chain lengths and their distribution. It was found that the average length is rather short and that it decreases with increasing concentration of the initiator. This technique has been also used to identify the radiation sensitive link in the CR-39 network. It was found that the length of polyallyl chain is not changed in 60 Co γ-irradiated plastic while the etch rate significantly increases. This shows that the polyallyl chains are relatively inert and not responsible for the radiation sensitivity of CR-39 and that it is the diethyleneglycol dicarbonate links which are damaged by radiation. (author)

  12. The LLNL CR-39 personnel neutron dosimeter

    International Nuclear Information System (INIS)

    Hankins, D.E.; Homann, S.; Westermark, J.

    1987-01-01

    We developed a personnel neutron dosimetry system based on the electrochemical etching of CR-39 plastic at elevated temperatures. The doses obtained using this dosimeter system are more accurate than those obtained using other dosimetry systems, especially when varied neutron spectra are encountered. This CR-39 dosimetry system does not have the severe energy dependence that exists with albedo neutron dosimeters or the fading and reading problems encountered with NTA film. 3 refs., 4 figs

  13. Advances in the development of Cr-39 based neutron dosimeters

    International Nuclear Information System (INIS)

    Hadlock, D.E.; Parkhurst, M.A.

    1987-12-01

    A combination thermoluminescent dosimeter (TLD) and track etch dosimeter (TED), which can be used for detecting neutrons over a wide energy range, has been developed through recent research in passive neutron dosimetery. This dosimeter uses Li-600 TLDs to detect thermal and low energy neutrons reflected from the body, and the TED polymer of CR-39, to detect fast neutrons from proton recoil interactions with the polyethylene radiator or with CR-39 itself. Some form of the combination dosimeter is currently in use at several US Department of Energy (DOE) facilities, and its use is expected to expand over the next year to include all DOE facilities where significant neutron exposures may occur. The extensive research conducted on the TED component over the past six years has continually focused on material improvements, reduction in processing time and dosimeter handling, and ease of sample readout with the goal of automating the process as much as possible. 1 fig

  14. Gamma irradiation effects on the thermal, optical and structural properties of Cr-39 nuclear track detector

    International Nuclear Information System (INIS)

    Nouh, S.A.; Said, A.F.; Atta, M.R.; EL-Mellegy, W.M.; EL-Meniawi, S.

    2006-01-01

    A study of the effect of gamma irradiation on the thermal, optical and structural properties of CR-39 diglycol carbonate solid state nuclear track detector (SSNTD) has been carried out. Samples from CR-39 polymer were irradiated with gamma doses at levels between 20 and 300 KGy. Non-isothermal studies were carried out using thermo-gravimetry (TG), differential thermo-gravimetry (DTG) and differential thermal analysis (DTA) to obtain the activation energy of decomposition and the transition temperatures for the non-irradiated and irradiated CR-39 samples. In addition, optical and structural property studies were performed on non-irradiated and irradiated CR-39 samples using refractive index and X-ray diffraction measurements. The variation of onset temperature of decomposition (To) thermal activation energy of decomposition (Ea) melting temperature (Tm) refractive index (n) and the mass fraction of the amorphous phase with the gamma dose were studied. It was found that many changes in the thermal, optical and structural properties of the CR-39 polymer could be produced by gamma irradiation via the degradation and cross linking mechanisms. Also, the gamma dose gave an advantage for increasing the correlation between the thermal stability of CR-39 polymer and the bond formation created by the ionizing effect of gamma radiation

  15. Application of CR-39 to radon measurement

    International Nuclear Information System (INIS)

    Miyake, Hiroshi

    1988-01-01

    CR-39, an ally diglycol carbonate, has recently come into wider use as material for solid-state track detector. Etching with NaOH or KOH solution allow CR-39 to develop extremely clear etch pits attributed to alpha rays. The most widely used method for measuring radon concentration employs a plastic cup with a solid-state track detector mounted at its bottom to detect alpha rays resulting from radon or its daughters that disintegrate within or on the wall of the cup. Simple in mechanism and low in cost, this method is suitable for such a case where the radon concentration distribution over a wide area has to be measured by using a large number of devices. The concentration of radon alone can be measured with the aid of a filter attached to the mouth of the cup to remove the daughters of radon and thoron. The simplest and most effective way of improving the sensitivity of a solid-state track detector for radon concentration measurement is to electrostatically collect daughters resulting from decay of radon onto the surface of the detector. Another method widely used to determine the radon concentration is to measure the concentration of the radon daughters instead of direct measurement of the concentration of radon itself. (Nogami, K.)

  16. Mass spectrometry analysis of etch products from CR-39 plastic irradiated by heavy ions

    Science.gov (United States)

    Kodaira, S.; Nanjo, D.; Kawashima, H.; Yasuda, N.; Konishi, T.; Kurano, M.; Kitamura, H.; Uchihori, Y.; Naka, S.; Ota, S.; Ideguchi, Y.; Hasebe, N.; Mori, Y.; Yamauchi, T.

    2012-09-01

    As a feasibility study, gas chromatography-mass spectrometry (GC-MS) and matrix-assisted laser desorption ionization-mass spectrometry (MALDI-MS) have been applied to analyze etch products of CR-39 plastic (one of the most frequently used solid states nuclear track detector) for the understanding of track formation and etching mechanisms by heavy ion irradiation. The etch products of irradiated CR-39 dissolved in sodium hydroxide solution (NaOH) contain radiation-induced fragments. For the GC-MS analysis, we found peaks of diethylene glycol (DEG) and a small but a definitive peak of ethylene glycol (EG) in the etch products from CR-39 irradiated by 60 MeV N ion beams. The etch products of unirradiated CR-39 showed a clear peak of DEG, but no other significant peaks were found. DEG is known to be released from the CR-39 molecule as a fragment by alkaline hydrolysis reaction of the polymer. We postulate that EG was formed as a result of the breaking of the ether bond (C-O-C) of the DEG part of the CR-39 polymer by the irradiation. The mass distribution of polyallylalcohol was obtained from the etch products from irradiated and unirradiated CR-39 samples by MALDI-MS analysis. Polyallylalcohol, with the repeating mass interval of m/z = 58 Da (dalton) between m/z = 800 and 3500, was expected to be produced from CR-39 by alkaline hydrolysis. We used IAA as a matrix to assist the ionization of organic analyte in MALDI-MS analysis and found that peaks from IAA covered mass spectrum in the lower m/z region making difficult to identify CR-39 fragment peaks which were also be seen in the same region. The mass spectrometry analysis using GC-MS and MALDI-MS will be powerful tools to investigate the radiation-induced polymeric fragments and helping to understand the track formation mechanism in CR-39 by heavy ions.

  17. High energy charged particle registration in CR-39 polycarbonated detector

    International Nuclear Information System (INIS)

    Abdel-Wahab, M.S.; El Enany, N.; El Fiki, S.; Eissa, H.M.; El-Adl, E.H.; El-Feky, M.A.

    1991-01-01

    Track etch rate characteristics of CR-39 plastic detector exposed to 28 Si ions of 670 MeV energy have been investigated. Experimental results were obtained in terms of frequency distribution of the track diameter, track density and bulk etching rate. A dependence of the mean track diameter on energy was found. The application of the radiation effect of heavy ions on CR-39 in the field of radiation detection and dosimetry are discussed. Results indicated that it is possible to produce etchable tracks of 28 Si in this energy range in CR-39. We also report the etching characteristics of these tracks in the CR-39 detector. (orig.) [de

  18. Optimization of CR-39 for fast neutron dosimetry applications

    International Nuclear Information System (INIS)

    Vilela, E.; Fantuzzi, E.; Giacomelli, G.; Giorgini, M.; Morelli, B.; Patrizii, L.; Serra, P.; Togo, V.

    1999-01-01

    We present the results of an experimental work aimed at improving the performances of the CR-39[reg] (Registered Trademark of PPG Industries Inc.) nuclear track detector for neutron dosimetry applications. The work was done in collaboration with the Intercast Europe S.p.A., producer of CR-39 for commercial and scientific applications. We compare the CR-39 made with different additives concentrations and different polymerization processes. We evaluate the response of the CR-39 to fast neutrons from three sources: 241 Am-Be, 252 Cf and 238 Pu-Li. Particular attention was paid to background fluctuations that limit the lower detectable dose

  19. Ablation and cone formation mechanism on CR-39 by ArF laser irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Shakeri Jooybari, B., E-mail: baninshakery@gmail.com, E-mail: hafarideh@aut.ac.ir [Department of Energy Engineering and Physics, Amirkabir University of Technology, P.O. Box 15875-4413, Tehran, Islamic Republic of Iran (Iran, Islamic Republic of); Nuclear Science and Technology Research Institute NSRT, Tehran (Iran, Islamic Republic of); Afarideh, H., E-mail: baninshakery@gmail.com, E-mail: hafarideh@aut.ac.ir [Department of Energy Engineering and Physics, Amirkabir University of Technology, P.O. Box 15875-4413, Tehran, Islamic Republic of Iran (Iran, Islamic Republic of); Lamehi-Rachti, M. [Nuclear Science and Technology Research Institute NSRT, Tehran (Iran, Islamic Republic of); Ghergherehchi, M. [Department of Energy Engineering and Physics, Amirkabir University of Technology, P.O. Box 15875-4413, Tehran, Islamic Republic of Iran (Iran, Islamic Republic of); College of Information and Communication Engineering, Sungkyunkwan University, Suwon (Korea, Republic of)

    2015-03-07

    In this work, chemical properties, surface modification, and micro structures formation on ablated polyallyl di-glycol carbonate (CR-39) polymer by ArF laser irradiation (λ = 193 nm) at various fluences and pulse number were investigated. CR-39 samples have been irradiated with an ArF laser (193 nm) at a repetition rate of 1 Hz. Threshold fluence of ablation and effective absorption coefficient of CR-39 were determined. Conical microstructures (Taylor cone) formed on laser-ablated CR-39 exhibit: smooth, Taylor cone shape walls and sharp tips together with interference and well defined fringe-structure with a period of 230 nm, around cone base. Mechanism of cone formation and cone evolution of CR-39 ablated surface were investigated by change of fluences (at a given pulse number) and pulse number (at a given fluence). Cone height, cone base, and region of interface were increased in micrometer steps by increasing the total fluence. Depression on the base of the cone and the circular fringe were simulated. FTIR spectra were measured and energy dispersive x-ray analysis of irradiated and un-irradiated samples was performed.

  20. CR-39 as induced track detector in reactor: irradiation effect

    International Nuclear Information System (INIS)

    Zylberberg, H.

    1989-07-01

    A systematic study about reactor's neutrons radiation effect and gamma radiation effect on the properties of CR-39 that are significant for its use as induced fission track detector is showed. The following studies deserved attention: kinetics of the fission track chemical development; efficiency to register and to develop fission track; losses of developable tracks; variation in the number of developable tracks and variation in the visible and ultraviolet radiation spectrum. The dissertation is organized in seven specific chapters: solid state nuclear tracks (SSNT); CR-39 as SSNT; objectives and problems presentation; preparation and characterization of CR-39 as SSNT; gamma irradiation effect on the properties of CR-39 as SSNT; reactor neutron irradiation effect on the properties of CR-39 as SSNT and, results discussions and conclusions. The main work contributions are the use of CR-39 in the determination of fissionable nuclide as thorium and uranium in solid and liquid samples; gamma radiation damage on CR-39 as well as the reactor's neutron damage on CR-39. (B.C.A.) 62 refs, 53 figs, 21 tabs

  1. LET calibration for CR-39 detectors in different oxygen environments

    International Nuclear Information System (INIS)

    Zhou, D.; Semones, E.; Weyland, M.; Benton, E.R.

    2007-01-01

    High LET (linear energy transfer) radiation is the main contributor to the radiation field in low Earth orbit (LEO) in terms of dose equivalent. CR-39 plastic nuclear track detectors (PNTDs) can measure the LET spectrum and charge spectrum for the complicated radiation field in space. Previous research indicated that the sensitivity of CR-39 is different for CR-39 PNTDs working in different oxygen environments. LET calibration for CR-39 detectors in different oxygen environments is needed. Almost all the previous LET calibration work was carried out for CR-39 detectors in good-oxygen condition, LET calibration work for CR-39 in poor-oxygen condition has not been conducted until our work. Systematic LET calibrations were carried out by JSC-SRAG (Space Radiation Analysis Group) for CR-39 detectors working in different oxygen environments and abundant results of LET calibrations were obtained. This paper introduces the method for CR-39 LET calibration, presents and discusses the calibration results and some applications

  2. Investigations of CR39 dosimeters for neutron routine dosimetry

    International Nuclear Information System (INIS)

    Weinstein, M.; Abraham, A.; Tshuva, A.; German, U.

    2004-01-01

    CR-39 is a polymeric nuclear track detector which is widely used for neutron dosimetry. CR-39 detector development was conducted at a number of laboratories throughout the world(1,2) , and was accepted also for routine dosimetry. However, there are shortcomings which must be taken into consideration the lack of a dosimetry grade material which causes batch variations, significant angular dependence and a moderate sensitivity. CR-39 also under-responds for certain classes of neutron spectra (lower energy neutrons from reactors or high energy accelerator-produced neutrons).In order to introduce CR-39 as a routine dosimeter at NRCN, a series of checks were performed. The present work describes the results of some of our checks, to characterize the main properties of CR-39 dosimeters

  3. A study on alpha particles range in Cr-39

    International Nuclear Information System (INIS)

    Ibrahim, Z.A.; Talaat, T.M.; Abdel-Aziz, Kh.M.A.; El-Asser, M.R.

    2000-01-01

    Cr-39 plastic nuclear track detector has been used in range determination of alpha particles. A set of experiments was carried out for studying alpha energy and track diameter relationships. This work was done under the optimum conditions of Cr-39 etching in 6.25 N NaOH at 70 degree C for various etching times. Determination of alpha range in Cr-39 recorders was studied at different energy values using the over etched track profile technique. Data are discussed within the framework of track formation theory in plastic foils, comparison between experimental and theoretical values of alpha range is included

  4. Optimization of CR-39 for fast neutron dosimetry applications

    CERN Document Server

    Vilela, E; Giacomelli, G; Giorgini, M; Morelli, B; Patrizii, L; Serra, P; Togo, V

    1999-01-01

    We present the results of an experimental work aimed at improving the performances of the CR-39[reg] (Registered Trademark of PPG Industries Inc.) nuclear track detector for neutron dosimetry applications. The work was done in collaboration with the Intercast Europe S.p.A., producer of CR-39 for commercial and scientific applications. We compare the CR-39 made with different additives concentrations and different polymerization processes. We evaluate the response of the CR-39 to fast neutrons from three sources: sup 2 sup 4 sup 1 Am-Be, sup 2 sup 5 sup 2 Cf and sup 2 sup 3 sup 8 Pu-Li. Particular attention was paid to background fluctuations that limit the lower detectable dose.

  5. Note: Fast neutron efficiency in CR-39 nuclear track detectors

    Energy Technology Data Exchange (ETDEWEB)

    Cavallaro, S. [Dipartimento di Fisica ed Astronomia,Università di Catania, Via S. Sofia 44, 95123 Catania, Italy and INFN-LNS, Via S. Sofia 42, 95123 Catania (Italy)

    2015-03-15

    CR-39 samples are commonly employed for fast neutron detection in fusion reactors and in inertial confinement fusion experiments. The literature reported efficiencies are strongly depending on experimental conditions and, in some cases, highly dispersed. The present note analyses the dependence of efficiency as a function of various parameters and experimental conditions in both the radiator-assisted and the stand-alone CR-39 configurations. Comparisons of literature experimental data with Monte Carlo calculations and optimized efficiency values are shown and discussed.

  6. The effect of solarradiation and UV photons on the CR-39 nuclear track detector

    International Nuclear Information System (INIS)

    Saad, A.F.

    2003-01-01

    The effects induced in the CR-39 polymer detector by total solar radiation (TSR) and UV photons were investigated. Thr exposure of detector samples to solar photons was carried out according to certain conditions. The TSR exposure period started in the middle of july and lasted unitel 12 th of september. 2000: the hottest months in zagazig, egypt. Another set of detector samples was exposed to UV photons from a UV lamp for different intervals. After UV exposure, these detectors were analysed with an FT-IR sepectrometer of jasco type 5300 in transmission mode. The FT-IR spectra does not show any considerable modifications due to UV irradiation in that detector. The effects of UV light were compared with those of solar radiation containing ultraviolet photons , on the registration properties of this polymer detector. Preliminaryresults revealed a proportionate increase in bluk etch rate of CR-39 detector with the increase of exposure time to the solar radiation. The results indicated that the CR-39 polymer detector can be used as a solar radiation dosimeter

  7. Characterization of saturation of CR-39 detector at high alpha-particle fluence

    Directory of Open Access Journals (Sweden)

    M. El Ghazaly

    2018-04-01

    Full Text Available The occurrence of saturation in the CR-39 detector reduces and limits its detection dynamic range; nevertheless, this range could be extended using spectroscopic techniques and by measuring the net bulk rate of the saturated CR-39 detector surface. CR-39 detectors were irradiated by 1.5 MeV high alpha-particle fluence varying from 0.06 × 108 to 7.36 × 108 alphas/cm2 from Am-241 source; thereafter, they were etched in a 6.25N NaOH solution at a temperature of 70°C for different durations. Net bulk etch rate measurement of the 1.5 MeV alpha-irradiated CR-39 detector surface revealed that rate increases with increasing etching time and reaches its maximum value at the end of the alpha-particle range. It is also correlated with the alpha-particle fluence. The measurements of UV–Visible (UV–Vis absorbance at 500 and 600 nm reveal that the absorbance is linearly correlated with the fluence of alpha particles at the etching times of 2 and 4 hour. For extended etching times of 6, 10, and 14.5 hour, the absorbance is saturated for fluence values of 4.05 × 108, 5.30 × 108, and 7.36 × 108 alphas/cm2. These new methods pave the way to extend the dynamic range of polymer-based solid state nuclear track detectors (SSNTDs in measurement of high fluence of heavy ions as well as in radiation dosimetry. Keywords: Alpha Particle, Bulk Etch Rate, CR-39 Detector, Saturated Regime, UV–Vis Spectroscopy

  8. Personnel neutron dosimetry using electrochemically etched CR-39 foils

    International Nuclear Information System (INIS)

    Hankins, D.E.; Homann, S.; Westermark, J.

    1986-01-01

    A personnel neutron dosimetry system has been developed based on the electrochemical etching of CR-39 plastic at elevated temperatures. The doses obtained using this dosimeter system are more accurate than those obtained using other dosimetry systems, especially when varied neutron spectra are encountered. This Cr-39 dosimetry system does not have the severe energy dependence that exists with albedo neutron dosimeters or the fading and reading problems encountered with NTA film. The dosimetry system employs an electrochemical etch procedure that be used to process large numbers of Cr-39 dosimeters. The etch procedure is suitable for operations where the number of personnel requires that many CR-39 dosimeters be processed. Experience shows that one full-time technician can etch and evaluate 2000 foils per month. The energy response to neutrons is fairly flat from about 80 keV to 3.5 MeV, but drops by about a factor of three in the 13 to 16 MeV range. The sensitivity of the dosimetry system is about 7 tracks/cm 2 /mrem, with a background equivalent to about 8 mrem for new CR-39 foils. The limit of sensitivity is approximately 10 mrem. The dosimeter has a significant variation in directional dependence, dropping to about 20% at 90 0 . This dosimeter has been used for personnel neutron dosimetry at the Lawrence Livermore National Laboratory for more tha 18 months. 6 refs., 23 figs., 2 tabs

  9. Neutron detection using CR-39 and Atomic Force Microscopy (AFM)

    International Nuclear Information System (INIS)

    Vazquez L, C.; Fragoso, R.; Felix, R.; Golzarri, J.I.; Espinosa, G.; Castillo, F.

    2007-01-01

    AFM has been applied in many CR-39 track formation analyses. In this paper, the use of AFM in the neutron detection and analysis of the track formation is reported. The irradiation was made with an 1.5 GBq (0.5 Ci) 241 Am-Be neutron source, with and without a polyethylene radiator. The surface analysis was made to the CR-39 fresh material without irradiation, after the irradiation, and after a very short etching time. The results show important differences between the irradiation, with and without polyethylene radiator, and the latent tracks of the neutron in the CR-39 polycarbonate. The development of track formation after very short etching time and pits characterization were measured too using the AFM facilities. (Author)

  10. Studies on nitrogen mapping by various CR-39 track detectors

    Energy Technology Data Exchange (ETDEWEB)

    Somogyi, G.; Varga, Zs.; Hunyadi, I.; Freyer, K.; Treutler, H.Ch.

    1986-01-01

    The use of CR-39 track detectors for nitrogen distribution measurements via the /sup 14/N(n,p)/sup 14/C reaction is studied. The proton detection properties of different CR-39 products have been analyzed. The variation of background track density induced in the bulk of detectors is examined under different conditions of neutron irradiation. Analysis of our experimental data has led to the conclusion that the sources of proton background tracks are the fast neutron component of the neutron source, chlorine impurities in the detector and nitrogen diffused from the air into the upper layer of the detector. Efforts have been made to decrease the nitrogen content of diffusion origin by removing the upper detector layer and by outgassing the CR-39 sheet in vacuum before irradiation. Finally the ''signal/noise'' ratio for a steel specimen and the sensitivity of nitrogen determination are given.

  11. Alpha-particle radiobiological experiments using thin CR-39 detectors

    International Nuclear Information System (INIS)

    Chan, K. F.; Siu, S. Y. M.; McClella, K. E.; Tse, A. K. W.; Lau, B. M. F.; Nikezic, D.; Richardson, B. J.; Lam, P. K. S.; Fong, W. F.; Yu, K. N.

    2006-01-01

    The present paper studied the feasibility of applying comet assay to evaluate the DNA damage in individual HeLa cervix cancer cells after alpha-particle irradiation. We prepared thin CR-39 detectors (<20 μm) as cell-culture substrates, with UV irradiation to shorten the track formation time. After irradiation of the HeLa cells by alpha particles, the tracks on the underside of the CR-39 detector were developed by chemical etching in (while floating on) a 14 N KOH solution at 37 deg. C. Comet assay was then applied. Diffusion of DNA out of the cells could be generally observed from the images of stained DNA. The alpha-particle tracks corresponding to the comets developed on the underside of the CR-39 detectors could also be observed by just changing the focal plane of the confocal microscope. (authors)

  12. Gamma dosimetry with CR-39 etch track detector

    International Nuclear Information System (INIS)

    Matiullah; Dogar, A.H.; Ahmad, N.; Amin, M.; Kudo, Katsuhisa

    1999-01-01

    To preserve and improve the safety of food for commercial purposes, it is exposed to high gamma-ray doses. The gamma-ray doses used for this purpose range from 0.15 kGy to 50 kGy. At such high doses, the etching characteristics of CR-39 are severely affected. This property, therefore, can be used to develop a CR-39-based gamma dosimeter. In this context, systematic studies were carried out and the bulk etching rate was determined as a function of gamma-ray dose using different methods. (author)

  13. Sensitivity determination of CR-39 from Normal and inclined incidence

    International Nuclear Information System (INIS)

    Abou, A.A.; El-Kheir, A.A.; Daas, A.F.; Awwad, Z.; Reda, A.M.

    2000-01-01

    An experimental study have been carried out on alpha- particle track opening (Major and minor axes) using alpha-particles of different energies incident with different angels in addition to the normal incidence. The sensitivity of CR-39 in present work is determined for each of normal and inclined incidence. The results indicated a difference in the sensitivity according to angle of incidence. The variation of alpha- particle tracks (major and minor axes) are calculated and compared with our measured values. Also, it is found that the sensitivity of CR-39 detector is change due to the storage time at room temperature

  14. Range energy for heavy ions in CR-39

    International Nuclear Information System (INIS)

    Gil, L.R.; Marques, A.

    1987-01-01

    Range-energy relations in CR-39, for ions from He to Ar, are obtained after their effective nuclear charge. Comparison with earlier calculations and numerical results in the energy range 0,1 to 200 Mev/ Nucleon are also given. (M.W.O.)

  15. A CR-39 track dosemeter for routine individual neutron monitoring

    International Nuclear Information System (INIS)

    Luszik-Bhadra, M.; Alberts, W.G.; Dietz, E.; Guldbakke, S.; Matzke, M.; d'Errico, F.

    1994-01-01

    A personal neutron dosemeter for routine individual monitoring is proposed. It is based on a CR-39 track detector covered on three separate areas by converters with different boron contents and inserted into a commercial TLD albedo dosemeter capsule. The dose readings from three areas of the electrochemically etched CR-39 detector are combined to yield a dose equivalent response which is almost independent of the incident neutron energy in the range from thermal neutrons up to 20 MeV. In addition, the dose contributions of thermal, intermediate and fast neutrons can be determined separately. Unlike the TLD albedo dosemeter, which in general requires prior in-field calibration and whose use is then restricted to that field, this dosemeter can be used in neutron fields without any knowledge of the spectral distribution with the same calibration factor. The angular dependence of the dosemeter's response has been measured and compared with that of the directional dose equivalent H'(10). The lower limit of detection is 0.15 mSv. It is possible to obtain an independent, second dose reading from the same Cr-39 detector for neutron energies above 100 keV. The dosemeter has also been successfully tested for use in accident dosimetry applying chemical etching and an optical density reading of the CR-39 detector. (author)

  16. Measurement of indoor radon concentration by CR-39 track detector

    International Nuclear Information System (INIS)

    Yamamoto, Masayoshi; Yoneda, Shigeru; Nakanishi, Takashi.

    1990-01-01

    A convenient and cheap method for measuring indoor radon ( 222 Rn) concentration with a CR-39 track detector is described. The detector consisted of two sheets of CR-39 enclosed separately in two plastic pots : one covered by a filter (cup method) and another no covering (bare method). The bare method was used here to supplement the cup method. To compare with the result of the CR-39 detector, alpha-ray spectrometry was carried out with a Si(Au) detector in a controlled radon exposure chamber. Indoor radon concentration measured in 133 houses in several districts of Ishikawa Prefecture have been found to range from 6 Bq/m 3 to as high as 113 Bq/m 3 with a median value of 24 Bq/m 3 . The problems to measure indoor radon concentration using the CR-39 detector are also discussed with emphasis on the position of setting the detector in the room and the possible thoron contribution to the detector. (author)

  17. Alpha-particle response characteristics of CR-39

    International Nuclear Information System (INIS)

    Abou El-Khier, A.A.; Gaber, M.; El-Khatib, A.M.; Fawzy, M.A.

    1987-01-01

    The form of the response curve of the polycarbonate CR-39 for α-particles at relatively low energies has been established. The investigation included measurements of both bulk- and track-etch rates. The latter was measured as a function of α-particle energies. (author)

  18. Alpha particle track coloration in CR-39: Improved observability

    CERN Document Server

    Oezguemues, A

    1999-01-01

    A comparative study of the observability of alpha particle tracks in CR-39 was performed with an optical microscope before and after coloration. The implantation of ink helped in observing the damage zones. At first glance through the microscope, the coloration makes the tracks stand out right away. This coloration is helpful, from the start, in the morphological study of the tracks (size, area, orientation, shape, perimeter). This operation is advantageous in distinguishing the alpha particle tracks from stains or scratches. Thus, the routine counting of the tracks is more easily performed. Consequently, this procedure allowed us: to decrease significantly the standard deviation of the approximate total of the parameters given from the image analysis system (Olympus CUE2); to envision the possibility of reasonably decreasing the etching time in order to limit the loss of information caused by the destruction of the CR-39 during chemical etching and to use a weaker enlarging lens in order to cover a larger fi...

  19. Energy response study of modified CR-39 neutron personnel dosimeter

    International Nuclear Information System (INIS)

    Sathian, Deepa; Bakshi, A.K.; Datta, D.; Nair, Sreejith S.; Sathian, V.; Mishra, Jitendra; Sen, Meghnath

    2018-01-01

    Personnel neutron dosimetry is an integral part of radiation protection. No single dosimeter provides the satisfactory energy response, sensitivity, angular dependence characteristics and accuracy necessary to meet the requirement of an ideal personnel neutron dosimeter. The response of a personnel neutron dosimeter is critically dependent upon the energy distribution of the neutron field. CR-39 personnel neutron dosimeters were typically calibrated in the standard neutron field of 252 Cf and 241 Am-Be in our laboratory, although actual neutron fields may vary from the calibration neutron spectrum. Recently the badge cassette of the personnel neutron dosimeter was changed due to frequent damage of the PVC badge used earlier. This paper discusses energy response of CR-39 solid state nuclear track detector loaded in this modified badge cassette as per latest ISO recommendation

  20. LET spectrum measurements in Cr-39 PNTD with AFM

    International Nuclear Information System (INIS)

    Johnson, Carl Edward; DeWitt, Joel M.; Benton, Eric R.; Yasuda, Nakahiro; Benton, Eugene V.

    2010-01-01

    Energetic protons, neutrons, and heavy ions undergoing collisions with target nuclei of varying Z can produce residual heavy recoil fragments via intra-nuclear cascade/evaporation reactions. The particles produced in these non-elastic collisions generally have such extremely short range (∼< 10 μm) that they cannot be directly observed by conventional detection methods including CR-39 plastic nuclear track detector (PNTD) that has been chemically etched for analysis by standard visible light microscopy. However, high-LET recoil fragments having range on the order of several cell diameters can be produced in tissue during radiotherapy using proton and carbon beams. We have developed a method to analyze short-range, high-LET tracks in CR-39 plastic nuclear track detector (PNTD) using short duration chemical etching (∼< 1 μm) followed by automated atomic force microscope (AFM) scanning. The post-scan data processing used in this work was based on semi-automated matrix analysis opposed to traditional grey-scale image analysis. This method takes advantage of the 3-D data obtained via AFM to achieve robust discrimination of nuclear tracks from other features. Through automation of AFM scanning, sufficient AFM scan frames were obtained to attain an LET spectrum spanning the LET range from 200-1500 keV/μm. In addition to our experiments, simulations were carried out with the Monte Carlo transport code, FLUKA. To demonstrate this method, CR-39 PNTD was exposed to the proton therapy beam at Loma Linda University Medical Center (LLUMC) at 60 and 230 MeV. Additionally, detectors were exposed to I GeV protons at the NASA Space Radiation Laboratory (NSRL) at Brookhaven National Laboratory (BNL). For these exposures CR-39 PNTD, Al and Cu target foils were used between detector layers.

  1. Observation of anomalons in CR-39 track detectors

    International Nuclear Information System (INIS)

    Tincknell, M.L.; Price, P.B.

    1984-01-01

    The authors have observed fragments of 1.85 GeV/nucleon 40 Ar in CR-39 etched track detector and they find anomalously short mean free paths (mfp's) of secondary nuclei with 11 less than or equal to Z less than or equal to 17 in the first 2 cm after their production, at approx.3 standard deviations. This confirms previous reports of this anomalon effect in nuclear emulsion in a new detector with dissimilar potential systematic errors

  2. LET spectrum measurements in Cr-39 PNTD with AFM

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Carl Edward [Los Alamos National Laboratory; De Witt, Joel M [OSU, PHYSICS; Benton, Eric R [OSU, PHYSICS; Yasuda, Nakahiro [NIRS, HIMAC; Benton, Eugene V [UNIV OF SAN FRANCISCO

    2010-01-01

    Energetic protons, neutrons, and heavy ions undergoing collisions with target nuclei of varying Z can produce residual heavy recoil fragments via intra-nuclear cascade/evaporation reactions. The particles produced in these non-elastic collisions generally have such extremely short range ({approx}< 10 {mu}m) that they cannot be directly observed by conventional detection methods including CR-39 plastic nuclear track detector (PNTD) that has been chemically etched for analysis by standard visible light microscopy. However, high-LET recoil fragments having range on the order of several cell diameters can be produced in tissue during radiotherapy using proton and carbon beams. We have developed a method to analyze short-range, high-LET tracks in CR-39 plastic nuclear track detector (PNTD) using short duration chemical etching ({approx}< 1 {mu}m) followed by automated atomic force microscope (AFM) scanning. The post-scan data processing used in this work was based on semi-automated matrix analysis opposed to traditional grey-scale image analysis. This method takes advantage of the 3-D data obtained via AFM to achieve robust discrimination of nuclear tracks from other features. Through automation of AFM scanning, sufficient AFM scan frames were obtained to attain an LET spectrum spanning the LET range from 200-1500 keV/{mu}m. In addition to our experiments, simulations were carried out with the Monte Carlo transport code, FLUKA. To demonstrate this method, CR-39 PNTD was exposed to the proton therapy beam at Loma Linda University Medical Center (LLUMC) at 60 and 230 MeV. Additionally, detectors were exposed to I GeV protons at the NASA Space Radiation Laboratory (NSRL) at Brookhaven National Laboratory (BNL). For these exposures CR-39 PNTD, Al and Cu target foils were used between detector layers.

  3. On registration properties of Intercast Company CR-39

    International Nuclear Information System (INIS)

    Golovchenko, A.N.

    1991-01-01

    The CR-39 response function has been determined by using the accelerated particles of intermediate ( 2 H, 4 He, 12 C, 16 O, 20 Ne and 40 Ar) and relativistic ( 19 F) energies. The irradiated detectors were etched in 6N NaOH kept at 70 deg C. The response function is determined in a wide range of the ionization change. 10 refs.; 1 fig.; 2 tabs

  4. STUDYING THE STRUCTURAL, OPTICAL, CHEMICAL AND ELECTROCHEMICAL ETCHING CHANGES OF CR-39 FOR DOSEMETRIC APPLICATIONS.

    Science.gov (United States)

    Zaki, M F; Elshaer, Y H; Taha, Doaa H

    2017-12-01

    The present work shows the induced modification of the structural, optical, chemical etching and electrochemical etching parameters of CR-39 irradiated with alpha-particles. CR-39 polymer track detectors were irradiated with different fluences (1.62 × 106, 2.72 × 106, 3.82 × 106 and 5.21 × 106 particles/cm2) of alpha-particles using 241Am source. The structural and optical properties were measured by FT-IR spectroscopy, X-ray diffraction and UV/Vis spectroscopy, respectively. The FT-IR spectra reveal that no major changes in the typical functional groups of irradiated polymer detectors. The X-ray diffraction patterns show that a broad band in the region of 12° 27°, which refers to the presence of the combination of amorphous and crystalline phases. UV/Vis responses of irradiated polymer track detectors exhibit a single absorption band in the range of 254-352 nm that is correlated to the occurrence of electronic transition. Also, the changes in the chemical and electrochemical parameters due to alpha-irradiation are examined and thoroughly discussed. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  5. Proton radiographic characteristics of thin CR-39 detector

    International Nuclear Information System (INIS)

    Waheed, A.; Manzoor, S.; Khan, H.A.; Urlep, I.; Ilic, R.

    1991-01-01

    Two parameters, track registration sensitivity and densitometric response, were measured in radiography with a low energy (∼4.5 MeV) proton beam and a stack of thin (100μm) CR-39 detector foils. The optimum image quality was obtained at a layer removal thickness of about 1 μm. The image obtained under these conditions is characterized by a high track registration sensitivity (∼60%), high image contrast (the maximum value of the net optical density is ∼0.7) and high spatial resolution (∼1 μm). The application of the technique in biomedicine is illustrated by proton radiographs of botanical samples. (author)

  6. Measurements of radon in dwellings with CR-39 track detectors

    DEFF Research Database (Denmark)

    Majborn, Benny

    1986-01-01

    A passive integrating dosemeter has been designed for measuring natural radiation in dwellings. The dosemeter contains one or two CR-39 track detectors to measure radon and three thermoluminescence dosemeters to measure external radiation. The dosemeter was investigated in a pilot study in 1983....../84, and it is now used in a nationwide survey of natural radiation in Danish dwellings. The characteristics of the dosemeter with respect to radon measurements are presented, and the radon monitoring results obtained in the pilot study are summarized...

  7. CR-39 (PADC) Reflection and Transmission of Light in the Ultraviolet-Near-Infrared (UV-NIR) Range.

    Science.gov (United States)

    Traynor, Nathan B J; McLauchlin, Christopher; Dodge, Kenneth; McGarrah, James E; Padalino, Stephen J; McCluskey, Michelle; Sangster, T C; McLean, James G

    2018-04-01

    The spectral reflection (specular and diffuse) and transmission of Columbia Resin 39 (CR-39) were measured for incoherent light with wavelengths in the range of 200-2500 nm. These results will be of use for the optical characterization of CR-39, as well as in investigations of the chemical modifications of the polymer caused by ultraviolet (UV) exposure. A Varian Cary 5000 was used to perform spectroscopy on several different thicknesses of CR-39. With proper analysis for the interdependence of reflectance and transmittance, results are consistent across all samples. The reflectivity from each CR-39-air boundary reveals an increase in the index of refraction in the near-UV. Absorption observations are consistent with the Beer-Lambert law. Strong absorption of UV light of wavelength shorter than 350 nm suggests an optical band gap of 3.5 eV, although the standard analysis is not conclusive. Absorption features observed in the near infrared are assigned to molecular vibrations, including some that are new to the literature.

  8. Fast Neutron Dosimetry Using CR-39 Nuclear Track Detector

    International Nuclear Information System (INIS)

    ZAKI, M.; ABDEL-NABY, A.; MORSY, A.

    2010-01-01

    Measurement of the neutron dose in and around the neutron sources is important for the purpose of personnel and environmental neutron dosimetry. In the present study, a method for the measurement of neutron dose using the UV-Vis spectra of CR-39 plastic track detector was investigated. A set of CR-39 plastic detectors was exposed to 252 Cf neutron source, which had the yield of 0.68x10 8 /s, and neutron dose equivalent rate 1m apart from the source is equal to 3.8 mrem/h. The samples were etched for 10 h in 6.25 N NaOH at 70 o C. The absorbance of the etched samples was measured using UV-visible spectrophotometer as a function of neutron dose. It was observed that there was a linear relationship between the optical absorption of these detectors and neutron dose. This means that the exposure dose of neutron can be determined by knowing the optical absorption of the sample. These results were compared with previous study. It was found that there was a matching and good agreement with their investigations.

  9. Etching characteristics of nuclear tracks in CR-39 plastics

    International Nuclear Information System (INIS)

    Tsuruta, Takao; Isobe, Ginko.

    1984-01-01

    In using CR-39 plastics for individual neutron dosimeters, changes of etching efficiency cause significant error in dose estimation. Etching efficiency is subject to a number of parameters. In this study the influences of the parameters were examined by measuring the diameters of etch-pits formed by alpha-particles and enlarged by aqueous solutions of 25-35% KOH at 55-65 0 C for 4 hr. It has been observed that diameter changes at the rate of 8.3%/ 0 C in temperature, 8.2%/wt% in concentration and -0.60%/day in time after preparation of etchant. The diameter is unaffected by the supplying of up to 280ml/l, of distilled water for evaporation of etchant or by increase up to 5g/l of CR-39 dissolved in etchant. The magnitude of possible error has been estimated by parameter as well as in general, so as to obtain suggestions for improving etching treatment. (author)

  10. Alpha particle radiography and the track plastic detector CR-39

    International Nuclear Information System (INIS)

    Souza, Bismarck Amilar de.

    1991-05-01

    This work develops the radiographic technique using charged particle beams. This technique complements the X-ray conventional radiography, and presents some advantages in certain cases. The material used as nuclear plastic detector was CR-39, manufactured by Pershre Mould. England, of 250 and 1000 μm nominal thicknesses. The irradiations were made with 7 MeV/Nucleon alpha particles beams, accelerated in the CV-28 Cyclotron of Instituto de Engenharia Nuclear/CNEN - Rio de Janeiro. The etch conditions used were a Na OH 6,25 N solution at 70 0 C, varying the etch time, so that the best etch time was found to be six hours. The calibration curve is presented, which permits images interpretation, showed in terms of light transmittance (obtained using a micro densitometer), and in terms of energy losses suffered by alpha particles in several aluminum degradating thicknesses. This curve was checked by the use of other degradating materials: Mylar, Makrofol, and CR-39 itself. The influence of alpha particle beam FWHM widening on images quality, when it crosses several degradating materials, is also presented. Radiographs of some specimen are presented, including some images obtained varying some irradiation and etch parameters. (author). 62 refs., 22 figs., 19 tabs

  11. Development of neutron personnel monitoring system based on CR-39 solid state nuclear track detector

    International Nuclear Information System (INIS)

    Massand, O.P.; Kundu, H.K.; Marathe, P.K.; Supe, S.J.

    1990-01-01

    Personnel neutron monitoring aims at providing a method to evaluate the magnitude of the detrimental effects on the personnel exposed to neutrons. Neutron monitoring is done for a small though growing number of personnel working with neutrons in a wide range of situations. Over the years, many solid state nuclear track detectors (SSNTD) have been tried for neutron personnel monitoring. CR-39 SSNTD is a proton sensitive polymer and offers a lot of promise for neutron personnel monitoring due to its high sensitivity and lower energy threshold for neutron detection. This report presents the mechanism of track formation in this polymer, the development of this neutron personnel monitoring system in our laboratory, its various characteristics and its promise as a routine personnel neutron monitor. (author). 1 tab., 7 figs

  12. Modifications in the optical and thermal properties of a CR-39 polymeric detector induced by high doses of γ-radiation

    Science.gov (United States)

    Saad, A. F.; Ibraheim, Mona H.; Nwara, Aya M.; Kandil, S. A.

    2018-04-01

    Effects of γ-radiation on the optical and thermal properties of a poly allyl diglycol carbonate (PADC), a form of CR-39, polymer have been investigated. CR-39 detectors were exposed to γ-rays at very high doses ranging from 5.0 × 105 to 3.0 × 106 Gy. The induced changes were analyzed using ultraviolet-visible spectroscopy (UV-VIS) in absorbance mode, and thermogravimetric analysis (TGA). The UV-visible spectra of the virgin and γ-irradiated CR-39 polymer detectors displayed a significant decreasing trend in their optical energy band gaps for indirect transitions, whereas for the direct ones showed a little change. This drop in the energy band gap with increasing dose is discussed on the basis of the gamma irradiation induced modifications in the CR-39 polymeric detector. The TGA thermograms show that the weight loss rate increased with increase in dose, which may be due to the disordered system via scission followed by crosslinking in the irradiated polymer detector. The TGA thermograms also indicated that the CR-39 detector decomposed in three/four stages for the virgin and irradiated samples. The activation energy for thermal decomposition was determined using a type of Arrhenius equation based on the TGA experimental results. These experimental results so obtained can be well used in radiation dosimetry.

  13. Track sensitivity and the surface roughness measurements of CR-39 with atomic force microscope

    CERN Document Server

    Yasuda, N; Amemiya, K; Takahashi, H; Kyan, A; Ogura, K

    1999-01-01

    Atomic Force Microscope (AFM) has been applied to evaluate the surface roughness and the track sensitivity of CR-39 track detector. We experimentally confirmed the inverse correlation between the track sensitivity and the roughness of the detector surface after etching. The surface of CR-39 (CR-39 doped with antioxidant (HARZLAS (TD-1)) and copolymer of CR-39/NIPAAm (TNF-1)) with high sensitivity becomes rough by the etching, while the pure CR-39 (BARYOTRAK) with low sensitivity keeps its original surface clarity even for the long etching.

  14. Cr-39 fast neutron dosemeter based on A (n, α) converter

    International Nuclear Information System (INIS)

    Widayati, S.; Budiantari, T.

    1998-01-01

    The aim of this experiment is to obtained the response of Cr-39 as fast neutron dosemeter based on an (n, α) converter. Cr-39 was irradiated to AmBe fast neutron flux from 0.10 mSv to 2.5 mSv. Cr-39 processed by chemical etching with NaOH 20 % at temperature of 60 oC in six hours. The results of experiment showed that the response of Cr-39 based on an (n, α) converter is 6 times bigger than the response of Cr-39 without (n, α) converter. (author)

  15. Wide-range neutron dose determination with CR-39

    International Nuclear Information System (INIS)

    Arneja, A.R.; Waker, A.J.

    1995-01-01

    Optical density measurements of CR-30 irradiated with 252 Cf neutrons and chemically etched with 6.5 N KOH solution have been used to determine neutron absorbed doses between 0.1 and 10 Gy. Optimum etching conditions will depend upon the absorbed dose. Since it is not always possible to know the range of absorbed dose on a CR-39 dosemeter collected from personnel and area monitor stations in a criticality accident situation, a three-step two-hour chemical etch at 60 o C has been found to be appropriate. If after a total of six hours of chemical etching the optical density is found to be below 0.04 for 500 nm light (transmission > 90%) then further treatment in the form of electrochemical etching can be carried out to determine the lower absorbed dose. In this manner, absorbed doses below 0.1 Gy can be determined by counting tracks over a unit area. (author)

  16. Particularisation of Alpha Contamination using CR-39 Track Detectors

    International Nuclear Information System (INIS)

    Zakia, M.F.; El-Shaer, Y.H.

    2008-01-01

    Solid-state nuclear track detectors have found wide use in various domains of science and technology, e.g. in environmental experiments. The measurement of alpha activity on sources in an environment, such as air is not easy because of short penetration range of the alpha particles. Furthermore, the measurement of alpha activity by most gas ionization detectors suffers from the high background induced by the accompanying gamma radiation. Solid State Nuclear Track Detectors (SSNTDs) have been used successfully as detecting devices as passive system to detect the alpha contamination different surfaces. This work presents the response of CR-39 (for two types) to alpha particles from two sources, 238 Pu with energy 5 MeV and 241 Am with energy 5.4 MeV. The methods of etching and counting are investigated, along with the achievable linearity, efficiency and reproducibility. The sensitivity to low activity and energy resolution are studied

  17. Registration properties of different types of CR-39 in vacuum conditions of irradiation

    International Nuclear Information System (INIS)

    Golovchenko, A.N.; Tret'yakova, S.P.

    1991-01-01

    Sensitivity change has been studied of different types of CR-39 detectors (Pershore, Tastrak, Intercast, Ma-ND/α) in dependence on holding time of detector in vacuum chamber at the residual pressure P ≅ 2x10 -2 and ≅ 5x10 -3 Pa before their irradiation with alpha particles from thin 238 Pu source and accelerated charged ions with atomic number Z=2-10 and energy of 9.1 MeV/nucleon. Polymer of Intercast Company turned out to be the most stable one to vacuum effect, and detector does not change the sensitivity up to response function REL 200 ≅ 1 MeVxcm 2 xmg -1 in the mentioned experiment conditions. 7 refs.; 3 figs

  18. The response of CR-39 nuclear track detector to 1-9 MeV protons

    International Nuclear Information System (INIS)

    Sinenian, N.; Rosenberg, M. J.; Manuel, M.; McDuffee, S. C.; Casey, D. T.; Zylstra, A. B.; Rinderknecht, H. G.; Gatu Johnson, M.; Seguin, F. H.; Frenje, J. A.; Li, C. K.; Petrasso, R. D.

    2011-01-01

    The response of CR-39 nuclear track detector (TasTrak) to protons in the energy range of 0.92-9.28 MeV has been studied. Previous studies of the CR-39 response to protons have been extended by examining the piece-to-piece variability in addition to the effects of etch time and etchant temperature; it is shown that the shape of the CR-39 response curve to protons can vary from piece-to-piece. Effects due to the age of CR-39 have also been studied using 5.5 MeV alpha particles over a 5-year period. Track diameters were found to degrade with the age of the CR-39 itself rather than the age of the tracks, consistent with previous studies utilizing different CR-39 over shorter time periods.

  19. CR-39 plastic nuclear track detector and its application in nuclear science

    International Nuclear Information System (INIS)

    Zhai Pengji; Tang Xiaowei; Wang Long; Liang Tianjiao

    2000-01-01

    The transparent and stable plastic material CR-39 can be used as a nuclear track detector which is highly sensitive to charged particles. It can record tracks induced by protons , alphas, fission fragments and other charged particles. Among various available solid state nuclear track detectors CR-39 has the lowest deposited energy density detection-threshold. The response of CR-39 to charged particles and the response curve of υ T of different charged particles to REL are given. The CR-39 detector is widely used in studies of nuclear reactions, angular distributions and reaction cross-sections caused by neutrons and charged particles. Neutron spectra, over a wide energy range, can be measured by the combination of CR-39 and a transformation screen. The successful applications of CR-39 in alpha particle dosimetry, environmental science (especially in the measurement of radon) and in biomedicine, such as the analysis of alpha radioactivity in sections of organic tissues, are described

  20. Cutting thin sheets of allyl diglycol carbonate (CR-39) with a CW CO2, laser

    International Nuclear Information System (INIS)

    Kukreja, L.M.; Bhawalkar, D.D.; Basu, C.; Goswami, J.N.

    1984-01-01

    Recent studies have shown that Allyl Diglycol Carbonate, commercially known as CR-39 (the most sensitive among etch track detectors) can detect relativistic oxygen and other heavier nuclei. We are using large sheets of special grade CR-39 (DOP) in our experiment in Space Shuttle-Spacelab-3. As CR-39 is a highly brittle substance, special care is required to cut CR-39 shetts, especially in case of large sheets and circular cuts. A study of cutting of CR-39 sheets using laser light is described in this paper. It has been found that this method is sufficiently fast to handle large number of sheets and also equally safe for big sheets. A maximum speed up to 200 cm/min with a 5 x 10 4 W/cm 2 laser is obtained during the present study. This study also shows that laser cutting does not affect the track properties of CR-39. (orig.)

  1. A parameterization of nuclear track profiles in CR-39 detector

    Science.gov (United States)

    Azooz, A. A.; Al-Nia'emi, S. H.; Al-Jubbori, M. A.

    2012-11-01

    In this work, the empirical parameterization describing the alpha particles’ track depth in CR-39 detectors is extended to describe longitudinal track profiles against etching time for protons and alpha particles. MATLAB based software is developed for this purpose. The software calculates and plots the depth, diameter, range, residual range, saturation time, and etch rate versus etching time. The software predictions are compared with other experimental data and with results of calculations using the original software, TRACK_TEST, developed for alpha track calculations. The software related to this work is freely downloadable and performs calculations for protons in addition to alpha particles. Program summary Program title: CR39 Catalog identifier: AENA_v1_0 Program summary URL:http://cpc.cs.qub.ac.uk/summaries/AENA_v1_0.html Program obtainable from: CPC Program Library, Queen’s University, Belfast, N. Ireland Licensing provisions: Copyright (c) 2011, Aasim Azooz Redistribution and use in source and binary forms, with or without modification, are permitted provided that the following conditions are met • Redistributions of source code must retain the above copyright, this list of conditions and the following disclaimer. • Redistributions in binary form must reproduce the above copyright notice, this list of conditions and the following disclaimer in the documentation and/or other materials provided with the distribution This software is provided by the copyright holders and contributors “as is” and any express or implied warranties, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose are disclaimed. In no event shall the copyright owner or contributors be liable for any direct, indirect, incidental, special, exemplary, or consequential damages (including, but not limited to, procurement of substitute goods or services; loss of use, data, or profits; or business interruption) however caused and

  2. Polymerization, structure and track recording properties of CR-39 cured with UV photoinitiators

    International Nuclear Information System (INIS)

    Stejny, J.; Carrell, J.; Palmer, M.J.

    2000-01-01

    CR-39 monomer was cured isothermally at temperatures from 54.5 to 115 deg. C with UV sensitive photoinitiators to high conversions. The use of photoinitiators allowed the cure of CR-39 isothermally at high temperatures and eliminated the danger of thermal runaway present in the conventionally used thermal initiation with peroxides. It was found that the properties of the UV photoinitiated CR-39 were similar to the conventionally polymerized resin

  3. Applications of CR-39 solid state nuclear track detector to ion beam diagnosis

    International Nuclear Information System (INIS)

    Kanasaki, Masato; Hattori, Atsuto; Oda, Keiji; Yamauchi, Tomoya; Fukuda, Yuji; Sakaki, Hironao; Nishiuchi, Mamiko; Kondo, Kiminori; Kurashima, Satoshi; Kamiya, Tomihiro

    2012-01-01

    CR-39 solid state nuclear track detector, which was developed for optical lens, has been applied for various field such as radon surveys, measurement of galactic cosmic ray, cell irradiation experiment and so on. The CR-39 detectors have the great advantages of being insensitive to high energy photons and electrons and capable of detecting only ions in the mixed fields such as laser driven relativistic plasmas. Though there are some analytical methods of CR-39 to diagnose ion beam, unfortunately, only few researchers in the field of plasma know the methods. This article looks at how to use CR-39 detectors and introduce the accomplishment of the joint study JAEA and Kobe Univ. for application of CR-39 detectors to ion beam diagnosis. (author)

  4. CR-39 track detector for multi-MeV ion spectroscopy.

    Science.gov (United States)

    Jeong, T W; Singh, P K; Scullion, C; Ahmed, H; Hadjisolomou, P; Jeon, C; Yun, H; Kakolee, K F; Borghesi, M; Ter-Avetisyan, S

    2017-05-19

    We present the characteristics of track formation on the front and rear surfaces of CR-39 produced by laser-driven protons and carbon ions. A methodological approach, based on bulk etch length, is proposed to uniquely characterize the particle tracks in CR-39, enabling comparative description of the track characteristics in different experiments. The response of CR-39 to ions is studied based on the energy dependent growth rate of the track diameter to understand the intrinsic particle stopping process within the material. A large non-uniformity in the track diameter is observed for CR-39 with thickness matching with the stopping range of particles. Simulation and experimental results show the imprint of longitudinal range straggling for energetic protons. Moreover, by exploiting the energy dependence of the track diameter, the energy resolution (δE/E) of CR-39 for few MeV protons and Carbon ion is found to be about 3%.

  5. Calculating CR-39 Response to Radon in Water Using Monte Carlo Simulation

    International Nuclear Information System (INIS)

    Razaie Rayeni Nejad, M. R.

    2012-01-01

    CR-39 detectors are widely used for Radon and progeny measurement in the air. In this paper, using the Monte Carlo simulation, the possibility of using the CR-39 for direct measurement of Radon and progeny in water is investigated. Assuming the random position and angle of alpha particle emitted by Radon and progeny, alpha energy and angular spectrum that arrive at CR-39, the calibration factor, and the suitable depth of chemical etching of CR-39 in air and water was calculated. In this simulation, a range of data were obtained from SRIM2008 software. Calibration factor of CR-39 in water is calculated as 6.6 (kBq.d/m 3 )/(track/cm 2 ) that is corresponding with EPA standard level of Radon concentration in water (10-11 kBq/m 3 ). With replacing the skin instead of CR-39, the volume affected by Radon and progeny was determined to be 2.51 mm 3 for one m 2 of skin area. The annual dose conversion factor for Radon and progeny was calculated to be between 8.8-58.8 nSv/(Bq.h/m 3 ). Using the CR-39 for Radon measurement in water can be beneficial. The annual dose conversion factor for Radon and progeny was calculated to be between 8.8-58.8 nSv/ (Bq.h/m 3 ).

  6. Development of neutron dosimeter using CR-39 for measurement of ambient dose equivalent

    International Nuclear Information System (INIS)

    Maki, Daisuke; Shinozaki, Wakako; Ohguchi, Hiroyuki; Yamamoto, Takayoshi; Nakamura, Takayoshi

    2010-01-01

    A CR-39 has good advantages such as cumulative type dosimeter, small fading effect and gamma-ray insensitive. Therefore, we developed the wide energy-range environmental neutron dosimeter using eight CR-39s for area monitoring in this study. This dosimeter is made of octagonal columnar polyethylene block which height is 60 mm and bottom side is 25 mm. The dosimeter contains two types of CR-39s for fast neutron detection and slow neutron detection. Four CR-39s for fast neutron detection are used for detection of recoil protons produced by H (n, p) reactions. Four CR-39s for slow neutron detection are used with boron nitride converter to detect alpha-rays produced by 10 B (n, α) 7 Li reactions. Ambient dose equivalent is obtained by adding the number of etch-pits observed in four CR-39s for fast neutron detection to the number of etch-pits observed in four CR-39s for slow neutron detection with appropriate constants respectively. Dosimeters were irradiated with some energetic neutrons and evaluated results of ambient dose equivalent were compared with results from neutron transport calculations. Energy response of dosimeter shows good agreement with neutron fluence to ambient dose equivalent conversion coefficients. Directional dependence of dosimeter is at the same level as the rem-counter. (author)

  7. The Effect of Radiator on CR-39 Registration of Fast Neutrons

    International Nuclear Information System (INIS)

    El-Badrya, B.A.; Hegazya, T.M.; Morsya, A.A.; Zaki, M.F.

    2008-01-01

    Three different configurations of a personal neutron dosimeter using CR-39 plastic detector were placed in Plastiplast pouch composed from inside to outside of Aluminum ( 27 Al, 40 Ξ m), polyethylene (PE, 20 Ξ m), Cellulose Nitrate (CN, 40 Ξ m). One dosimeter was composed of a CR-39 detector and a PE radiator (1 mm thick), another of two CR-39 detectors with one serving as radiator, and the other of CR-39 alone (without radiator). These dosimeters have been irradiated with fast neutrons of average energy 4.5 MeV with neutron fluence ranging from 5.5 x 10 6 to 0.5 x 10 8 cm - 2 emitted from 241 Am-Be neutron source. The polymeric materials have been chosen on the basis of their hydrogen contents, which are as followed: CR-39, 48%, Polyethylene, 66.7% and CN, 32% by atomic ratio to produce protons via (n, p) elastic scattering with hydrogen and increasing the detection efficiency of CR-39. After irradiation, the dose equivalent response of the detectors has been studied by using conventional etching for two periods, 6h and 8h for these configurations. The thicknesses and compositions of the radiators are chosen so as to suppress the CR-39 response below 4 MeV by preventing the recoils of hydrogen nuclei, out of the hydrogen-rich radiators (PE, CR-39), from reaching the post-etch surface of the detector. Track counting was performed using an automated system. It was found that the dosemeter responses were linear as a function of a neutron equivalent dose and that the CR-39 detector has the same response with radiator or without radiator and thus appears as a promising fast neutron dosimeter. The results are discussed and compared with the literature

  8. The Use Of Optical Properties Of Cr-39 In Alpha Particle Equivalent Dose Measurements

    International Nuclear Information System (INIS)

    Shnishin, K.A.

    2007-01-01

    In this work, optical properties of alpha irradiated Cr-39 were measured as a function of optical photon wavelength from 200-1100 nm. Optical energy gap and optical absorption at finite wavelength was also calculated and correlated to alpha fluence and dose equivalent. Alpha doses were calculated from the corresponding irradiation fluence and specific energy loss using TRIM computer program. It was found that, the optical absorption of unattached Cr-39 was varied with alpha fluence and corresponding equivalent doses. Also the optical energy gab was varied with fluence and dose equivalent of alpha particles. This work introduces a reasonably simple method for the Rn dose equivalent calculation by Cr-39 track

  9. Effect of radiation on the electrical properties of plastic detector CR-39

    International Nuclear Information System (INIS)

    Mahmoud, S.A.; Hamed, A.E.; Abou El-Kier, A.A.; Mousse, M.G.; Kassem, M.E.; El-Shafey, E.M.

    1994-01-01

    The effect of high alpha-particle fluence on plastic detector CR-39 was studied by measuring the electrical properties of the detector as a function of irradiation dose and frequency using an impedance meter in the frequency range 0.005-500 kHz. When the plastic detector CR-39 is exposed to high irradiation doses, it loses its advantage as a track detector, because of the overlapping of the tracks occurring in the detector at high irradiation fluence. Through the present measurements of dielectric permittivity and conductivity at different frequencies and temperatures, CR-39 could be used as a dosimeter for high irradiation doses

  10. Effect of radiation on the electrical properties of plastic detector CR-39

    Energy Technology Data Exchange (ETDEWEB)

    Mahmoud, S.A.; Hamed, A.E.; Abou El-Kier, A.A.; Mousse, M.G.; Kassem, M.E.; El-Shafey, E.M. (Physics Department Faculty of Science, Alexandria University, Alexandria (Egypt))

    1994-10-15

    The effect of high alpha-particle fluence on plastic detector CR-39 was studied by measuring the electrical properties of the detector as a function of irradiation dose and frequency using an impedance meter in the frequency range 0.005-500 kHz. When the plastic detector CR-39 is exposed to high irradiation doses, it loses its advantage as a track detector, because of the overlapping of the tracks occurring in the detector at high irradiation fluence. Through the present measurements of dielectric permittivity and conductivity at different frequencies and temperatures, CR-39 could be used as a dosimeter for high irradiation doses.

  11. Detection of light charged particles from plasma focus by CR-39

    Energy Technology Data Exchange (ETDEWEB)

    Antanasijevic, R.; Vukovic, J.; Popovic, S.; Popovic, M. (Belgrade Univ. (Yugoslavia). Inst. za Fiziku); Puric, J.; Cuk, M. (Faculty of Physical Science, Belgrade (Yugoslavia))

    1991-01-01

    An analysis of a deuteron (D{sup +}) beam, emitted from a plasma focus has been carried out, using a CR-39 plastic nuclear track detector. The CR-39 was pretreated using different processes to destroy the existing background before exposing it to the particles produced in the plasma focus. From measurements of the diameters of the tracks, the estimated energy of the D{sup +} ions is about 0.5 MeV. The total number of emitted D{sup +} ions was 10 particles/pulse. Some preliminary results on imaging etched CR-39 with an Atomic Force Microscope (NanoScope AFM) are also presented. (author).

  12. Detection of light charged particles from plasma focus by CR-39

    International Nuclear Information System (INIS)

    Antanasijevic, R.; Vukovic, J.; Popovic, S.; Popovic, M.

    1991-01-01

    An analysis of a deuteron (D + ) beam, emitted from a plasma focus has been carried out, using a CR-39 plastic nuclear track detector. The CR-39 was pretreated using different processes to destroy the existing background before exposing it to the particles produced in the plasma focus. From measurements of the diameters of the tracks, the estimated energy of the D + ions is about 0.5 MeV. The total number of emitted D + ions was 10 particles/pulse. Some preliminary results on imaging etched CR-39 with an Atomic Force Microscope (NanoScope AFM) are also presented. (author)

  13. gamma-induced modification on optical band gap of CR-39 SSNTD

    International Nuclear Information System (INIS)

    Zaki, M.F.

    2010-01-01

    effect of gamma irradiation on optical absorption of nuclear track detectors like CR-39 was studied at different absorbed doses using ultraviolet-visible (UV-VIS)spectroscopy. the existence of the peaks, their shifting and broadening as a result of gamma irradiation has been discussed. the width of the tail of localized states in the band gap (E u )was evaluated using the Urbach edge method. finally the indirect and direct band gap in pristine and gamma irradiated CR-39 have been determined. the values of indirect band gap have been found to be lower than the corresponding values of direct band gap. a decrease in the optical energy gap with increasing the gamma absorbed dose can be discussed on the basis of gamma-irradiation-induced defects in the CR-39. the correlation between optical band gap and the number of carbon atoms in a cluster with modified Tauc's equation has been discussed in case of CR-39.

  14. Dose-equivalent response CR-39 track detector for personnel neutron dosimetry

    International Nuclear Information System (INIS)

    Oda, K.; Ito, M.; Yoneda, H.; Miyake, H.; Yamamoto, J.; Tsuruta, T.

    1991-01-01

    A dose-equivalent response detector based on CR-39 has been designed to be applied for personnel neutron dosimetry. The intrinsic detection efficiency of bare CR-39 was first evaluated from irradiation experiments with monoenergetic neutrons and theoretical calculations. In the second step, the radiator effect was investigated for the purpose of sensitization to fast neutrons. A two-layer radiator consisting of deuterized dotriacontane (C 32 D 66 ) and polyethylene (CH 2 ) was designed. Finally, we made the CR-39 detector sensitive to thermal neutrons by doping with orthocarbone (B 10 H 12 C 2 ), and also estimated the contribution of albedo neutrons. It was found that the new detector - boron-doped CR-39 with the two-layer radiator - would have a flat response with an error of about 70% in a wide energy region, ranging from thermal to 15 MeV. (orig.)

  15. Calculation of thermal effects occuring during the manufacture of CR-39 sheets

    Energy Technology Data Exchange (ETDEWEB)

    Szilagyi, S.; Somogyi, G.

    1984-01-01

    To manufacture a good-quality, uniform CR-39 track detector, the polymerization rate should be below a critical value to avoid the development of undesirable thermal gradients and internal temperature fluctuations in the sheet being cast. To improve curing cycles a computer program was developed to study the trends of thermal effects under different casting conditions. These calculations are based on the solution of the one-dimensional heat transport equation and take into account the relations proposed by Dial et. al. for describing the chemical kinetics of CR-39 polymerization. The authors have revised the empirical parameters available to such calculations. With new ''Dial constants'' they have calculated the critical initial bath temperature (which results in thermal runaway at the central plane of the sheet being cast) as a function of the CR-39 thickness and IPP initiator concentration. Results are also presented for the temperature profile in the depth of cast CR-39 sheets.

  16. Optical, structural, and chemical properties of CR-39 implanted with 5.2 MeV doubly charged carbon ions

    Science.gov (United States)

    Ali, Dilawar; Butt, M. Z.; Ishtiaq, Mohsin; Waqas Khaliq, M.; Bashir, Farooq

    2016-11-01

    Poly-allyl-diglycol-carbonate (CR-39) specimens were irradiated with 5.2 MeV doubly charged carbon ions using Pelletron accelerator. Ion dose was varied from 5 × 1013 to 5 × 1015 ions cm-2. Optical, structural, and chemical properties were investigated by UV-vis spectroscopy, x-ray diffractometer, and FTIR/Raman spectroscopy, respectively. It was found that optical absorption increases with increasing ion dose. Absorption edge shifts from UV region to visible region. The measured opacity values of pristine and ion implanted CR-39 range from 0.0519 to 4.7959 mm-1 following an exponential growth (9141%) with the increase in ion dose. The values of direct and indirect band gap energy decrease exponentially with an increase in ion dose by 59% and 71%, respectively. However, average refractive index in the visible region increases from 1.443 to 2.864 with an increase in ion dose, by 98%. A linear relation between band gap energy and crystallite size was observed. Both the number of carbon atoms in conjugation length and the number of carbon atoms per cluster increase linearly with the increase in ion dose. FTIR spectra showed that on C+2 ions irradiation, the intensity of all bands decreases gradually without appearance of any new band, indicating degradation of polymer after irradiation. Raman spectra revealed that the density of -CH2- group decreases on C+2 ions irradiation. However, the structure of CR-39 is completely destroyed on irradiation with ion dose 1 × 1015 and 5 × 1015 ions cm-2.

  17. Development of hybrid track detector using CR39 and photographic plate

    International Nuclear Information System (INIS)

    Kuge, Kenichi; Endo, Yusuke; Hayashi, Kentaro; Hasegawa, Akira; Kumagai, Hiroshi

    2004-01-01

    Hybrid track detector using CR39 and color photography was prepared by coating multi-layered color photographic emulsions on one side of CR39. Etch pits and color tracks were observed at the same time. Photographic plate with different sensitivity emulsions and couplers were exposed to light, α-, β- and γ-rays. We observed sensitivity difference to the radiation by color changes on one plate. (authors)

  18. CR-39 α track detector and its application in observing of the hot particles in environment

    International Nuclear Information System (INIS)

    Zou Benchuan

    1992-01-01

    CR-39 α track detector is a new α remitting radionuclides plastic detector. It is audio-visual, convenient and economic in the detection of α particle track and the distribution of α emitting radionuclides in environmental samples. CR-39 α track detector is used to observe the hot particles in rock and the hot particles coming from the liquid effluents discharged by spent fuel reprocessing plant in UK in marine environment and got good results

  19. Proton an alpha detections by track recording technique in CR-39

    International Nuclear Information System (INIS)

    Oliveira, W.A. de; Franco, M.A.R.; Herdade, S.B.; Khouri, M.C.F.; Goncalez, O.L.

    1986-07-01

    The plastic CR-39 is utilized as proton track detector in the study of the reaction 27 A (e, p) and 59 Co (e, p), near threshold. Preliminary results are presented for the energy calibration (mean track diameter as a function of proton energy) of CR-39 with mono-energetic protons of a Van de Graaff accelerator, in the energy range 1-3 MeV. (author) [pt

  20. Simple preparation of thin CR-39 detectors for alpha-particle radiobiological experiments

    International Nuclear Information System (INIS)

    Chan, K.F.; Lau, B.M.F.; Nikezic, D.; Tse, A.K.W.; Fong, W.F.; Yu, K.N.

    2007-01-01

    Alpha-particle radiobiological experiments involve irradiating cells with alpha particles and require accurate positions where the alpha particles hit the cells. In the present work, we prepared thin CR-39 detectors from commercially available CR-39 SSNTDs with a thickness of 100 μm by etching them in 1 N NaOH/ethanol at 40 deg. C to below 20 μm. The desired final thickness was achieved within ∼8 h. Such etching conditions can provide relatively small roughness of the detector as revealed by atomic force microscope, and thus provide transparent detectors for radiobiological experiments. UV radiation was employed to shorten track formation time on these thin CR-39 detectors. After exposure to UV light (UVA + B radiation) for 2-3 h with doses from 259 to 389 W/cm 2 , 5 MeV alpha-particle tracks can be seen to develop on these CR-39 detectors clearly under the optical microscope within 2 h in 14 N KOH at 37 deg. C. As an example for practical use, custom-made petri dishes, with a hole drilled at the bottom and covered with a thin CR-39 detector, were used for culturing HeLa cells. The feasibility of using these thin CR-39 detectors is demonstrated by taking photographs of the cells and alpha-particle tracks together under the optical microscope, which can allow the hit positions on the cells by the alpha particles to be determined accurately

  1. Track etch parameters and annealing kinetics assessment of protons of low energy in CR-39 detector

    International Nuclear Information System (INIS)

    Jain, R.K.; Kumar, Ashok; Singh, B.K.

    2012-01-01

    Highlights: ► We calibrate CR-39 detector with very low energy protons. ► We establish linear relationship between track diameter and time/energy up to 200 keV. ► We determine activation energy of annealing using different models. ► We justify concept of single annealing activation energy in CR-39. - Abstract: In this paper threshold of the registration sensitivity of very low energy proton in CR-39 is investigated. Irradiation of CR-39 (poly-allyl-diglycol carbonate) was carried out with very low energy mono energetic protons of 20–60 keV from a mini proton accelerator. Nearly 10 4 /cm 2 fluence of protons was used. The variation of track diameter with etching time as well as proton energy response curve was carefully calibrated. The bulk and track etch rates were measured by using proton track diameters. Bulk etch rate was also measured by the thickness of removed surface layer. The thermal annealing of proton track at temperatures ranging from 100 to 200 °C in CR-39 was studied by several models. Activation energy of annealed CR-39 detectors was calculated by slope of track etch rate and temperature plot. The data of proton tracks of 200, 250 and 300 keV from 400 kV Van-de-Graaff accelerator was also used and compared with the track diameters of different energies of proton.

  2. Use of CR-39 foils for personnel neutron dosimetry: improved electrochemical etching chambers and procedures

    International Nuclear Information System (INIS)

    Hankins, D.E.; Homann, S.G.; Westermark, J.

    1986-01-01

    The electrochemical etching procedures for the new dosimetry system that uses foils of CR-39 plastic has been improved. During 1985, the etching chambers were modified to correct several problems and the changes to the etching procedures were studied, which gave a more uniform track density and size. The currently recommended etch parameters are given. A new generation of CR-39 material from the manufacturer proved to have a considerably lower background track density and a higher sensitivity; the new foils are also more uniform in thickness, which eliminates the need to numerically compensate for thickness variations. The energy dependence of the CR-39 using monoenergetic neutrons from accelerators at Battelle Northwest Laboratories and at Los Alamos National Laboratory was determined. Some variation was found in the energy dependence, but it is believed this was caused by changes in the etching procedures and by uncertainties in the fluences of the neutrons from the accelerators. A means by which the counting of CR-39 tracks may be automated is suggested; this would be very useful in adapting the CR-39 dosimetry system to large-scale use

  3. Fast neutron irradiation effects on CR-39 nuclear track detector for dosimetric applications

    International Nuclear Information System (INIS)

    Kader, M.H.

    2005-01-01

    The effect of neutron irradiation on the dosimetric properties of CR-39 solid-state nuclear track detector have been investigated. CR-39 samples were irradiated with neutrons of energies follow a Maxwellian distribution centered about 2 MeV. These samples were irradiated with different doses in the range 0.1-1 Sv. The background and track density were measured as a function of etching time. In addition, the dependence of sensitivity of CR-39 detector on the neutrons dose has been investigated. The results show that the Sensitivity started to increase at 0.4 Sv neutrons dose, so this sample were chosen to be a subject for further study to investigate the effect of gamma dose on its properties. The sample irradiated with 0.4 Sv were exposed to different doses of gamma rays at levels between 10 and 80 kGy. The effect of gamma doses on the bulk etching rate VB, the track diameter and the sensitivity of the CR-39 samples was investigated. The results show that the dosimetric properties of CR-39 SSNTD are greatly affected by both neutron and gamma irradiation

  4. Calculation of thermal effects occurring during the manufacture of CR-39 sheets

    Energy Technology Data Exchange (ETDEWEB)

    Szilagyi, S.; Somogyi, G. (Magyar Tudomanyos Akademia, Debrecen. Atommag Kutato Intezete)

    1984-01-01

    To manufacture a good-quality, uniform CR-39 track detector, the polymerization rate should be chosen below a critical value to avoid the development of undesirable thermal gradients and internal temperature fluctuations in the sheet being cast. To improve curing cycles, especially for thick CR-39 sheets, a computer programme was developed by which we could study the trends of thermal effects under different casting conditions. Our calculations are based on the solution of the one dimensional heat transport equation, taking into account the relations proposed by Dial et al (1955) for describing the chemical kinetics of CR-39 polymerization. We have revised the empirical parameters available to such calculations. With new 'Dial constants' we have calculated the critical initial bath temperature (which results in thermal runaway at the central plane of the sheet being cast) as a function of the CR-39 thickness and IPP initiator concentration. Results are also presented for the temperature profile developing in the depth of cast CR-39 sheets.

  5. Calculation of thermal effects occurring during the manufacture of CR-39 sheets

    International Nuclear Information System (INIS)

    Szilagyi, S.; Somogyi, G.

    1984-01-01

    To manufacture a good-quality, uniform CR-39 track detector, the polymerization rate should be chosen below a critical value to avoid the development of undesirable thermal gradients and internal temperature fluctuations in the sheet being cast. To improve curing cycles, especially for thick CR-39 sheets, a computer programme was developed by which we could study the trends of thermal effects under different casting conditions. Our calculations are based on the solution of the one dimensional heat transport equation, taking into account the relations proposed by Dial et al (1955) for describing the chemical kinetics of CR-39 polymerization. We have revised the empirical parameters available to such calculations. With new 'Dial constants' we have calculated the critical initial bath temperature (which results in thermal runaway at the central plane of the sheet being cast) as a function of the CR-39 thickness and IPP initiator concentration. Results are also presented for the temperature profile developing in the depth of cast CR-39 sheets. (author)

  6. Personnel neutron dosimetry applications of track-size distributions on electrochemically etched CR-39 foils

    International Nuclear Information System (INIS)

    Hankins, D.E.; Homann, S.G.; Westermark, J.

    1988-01-01

    The track-size distribution on electrochemically etched CR-39 foils can be used to obtain some limited information on the incident neutron spectra. Track-size distributions on CR-39 foils can also be used to determine if the tracks were caused by neutrons or if they are merely background tracks (which have a significantly different track-size distribution). Identifying and discarding the high-background foils reduces the number of foils that must be etched. This also lowers the detection limit of the dosimetry system. We have developed an image analyzer program that can more efficiently determine the track density and track-size distribution, as well as read the laser-cut identification numbers on each foil. This new image analyzer makes the routine application of track-size distributions on CR-39 foils feasible. 2 refs., 3 figs

  7. Effect of Gamma Rays on Fast Neutron Registration in CR-39

    CERN Document Server

    Kobzev, A P; El-Halem, A A; Abdul-Ghaphar, U S; Salama, T A

    2002-01-01

    A set of CR-39 plastic detectors with front PE radiator was exposed to Am-Be neutron source, which has an emission rate of 0.86\\cdot 10^{7} sec^{-1}, and the neutron dose equivalent rate 1 m apart from the source is equal to 11 mrem/hr. Another set of samples was irradiated by a neutron dose of 4 rem, then exposed to different gamma-ray doses using ^{60}Co source. It was found that the track density grows with the increase of neutron dose and etching time. It was also found that the bulk etching rate V_{B}, the track diameter and the sensitivity of the CR-39 plastic detector with respect to the neutron irradiation increased with increasing gamma-ray dose in the range 1?10 Mrad. These results show that CR-39 can be considered as a promising fast neutron dosimeter and gamma-ray dosimeter.

  8. Personal Dosemeter of Thermal Neutron Using A Cr-39 Detector with Filter Natural LiF

    International Nuclear Information System (INIS)

    Sofyan, Hasnel; Thamrin, M.Thoyib

    1996-01-01

    The research of personal dosemeter for thermal neutron using Cr-39 detector with different thicknesses of natural LiF filter was carried out. The irradiation of Cr-39 detector with neutron source from reactor research TRIGA mark II of Rikkyo University Tokyo, Japan. Nuclear track was counted by automatic method with ASPECT ver.4.22 Series A4T124 software and manual method for correction. The result of research, the maximum of nuclear tracks was obtained at 8 mm of LiF filter was 10 mm with 11,630x10E-5 track/neutron for air radiation. And on phantom radiation, the thickness of filter was 10 mm with 11,630x10E-5 track/neutron. Its values were 3.6 and 7.5 bigger than the response of Cr-39 non filter in air and on phantom radiation, respectively

  9. CR-39 and Lexan calibrated as low-LET radiation dosimeter, for three Mexican irradiation facilities

    International Nuclear Information System (INIS)

    Tavera, L.; Balcazar, M.; Matamoros, H.; Carrasco, H.

    2005-01-01

    An experimental calibration of two common nuclear track detectors, CR-39 and Lexan, for gamma and electrons radiation, was performed using various irradiation facilities. The dose response was obtained as a function of two parameters, the bulk etch rate and the UV absorbance for a wide dose range from 10 to 1000 kGy. The bulk etch rate sensitivity, for gamma and electrons, in CR-39 detector is higher than for Lexan detector. Lexan has a well-defined UV absorbance spectrum, but presents saturation for doses higher than 500 kGy, the same saturation characteristic is observed for the corresponding bulk etch rate response. For electron and gamma radiation, CR-39 shows a good response for doses from 10 kGy up to 1000 kGy, where data fit well an exponential curve for electrons and a lineal curve for gamma radiation

  10. Beam profile measurement with CR-39 track detector for low-energy ions

    CERN Document Server

    Sato, F; Tanaka, T; Iida, T; Yamauchi, T; Oda, K

    1999-01-01

    A CR-39 track detector was successfully used to measure the outline of thin low-energy ion beams. After the etching, the surface of the detector was examined with an observation system composed of a Normarski microscope, a CCD camera and a digital image processing computer. Beam images obtained with the system were in good agreement on the outline of the beam formed with a beam aperture. Also, the resolving power in the beam outline measurement was roughly explained from the consideration of the ion range and the etch-pit growth in the chemical etching for the CR-39 detector.

  11. Characterization of a alpha particle detector CR-39 exposed to a source of radium

    International Nuclear Information System (INIS)

    Maino, Leandro Marcondes

    2009-01-01

    In this project, the main goal is the characterization of a alpha particle detector CR-39 exposed to a source of radio. Three detectors were exposed to a source of radium and then chemically treated for different periods. This way, we could analyze these samples and collect the information needed to verify that at least one of the chemical attack, there has been a separation of the energies alpha particles incident with distinct peaks, thus characterizing the CR-39 as alpha spectrometer in the range 2.5 to 6.3 MeV . (author)

  12. CR-39 nuclear track detector used for neutron dosimetry: system calibration

    International Nuclear Information System (INIS)

    Saint Martin, G.; Lopez, F.; Bernaola, Omar A.

    2009-01-01

    Stacks composed by 1 mm thickness CR-39 foils and polyethylene and PVC films were evaluated to be used as neutron dosemeters. Irradiations were made with a calibrated 241 Am-Be source in a dose range from 0 to 3.1 mSv and the etching conditions were optimized. The measurements of number of tracks per surface unit in the CR-39 detectors showed a good linear behaviour as a function of the dose. The minimum detectable dose equivalent (MDDE) was calculated. (author)

  13. Characteristics of neutron-irradiated CR-39 foils treated by sequential chemical and electrochemical etching

    International Nuclear Information System (INIS)

    Somogyi, G.; Dajko, G.; Turek, K.; Spurny, F.

    1982-01-01

    The density of background spots revealed by chemical (CE) and electrochemical (ECE) etching and by their sequential application (CE + ECE) has been measured in several sorts of CR-39 material. The trends in the variation of sensitivity to Am-Be neutrons have been determined in CR-39 sheets covered by thick proton-radiator, when changing the field strength, frequency, etchant concentration, pre-etch duration and the fluence of neutrons. The results are analyzed in order to find out an optimum set of experimental parameters which may be proposed to attain high registration sensitivity to neutrons. (author)

  14. Present status of fast neutron personnel dosimetry system based on CR-39 solid state nuclear track detectors

    International Nuclear Information System (INIS)

    Pal, Rupali; Sathian, Deepa; Jayalakshmi, V.; Bakshi, A.K.; Chougaonkar, M.P.; Mayya, Y.S.; Kumar, Valli; Babu, Rajesh; Kar, S.; Joshi, V.M.

    2011-08-01

    Neutron sources are of different types depending upon the method of production such as nuclear reactors, particle accelerators and laboratory sources. Neutron sources depending upon their energy, flux, size etc. are used for variety of applications in basic and applied sciences, neutron scattering experiments and in industry such as oil well - digging, coal mining and processing, ore processing etc. Personnel working in nuclear installations such as reactors, accelerators, spent fuel processing plants, nuclear fuel cycle operations and those working in various industries such as oil refining, oil well-digging, coal mining and processing, ore processing, etc. need to be monitored for neutron exposures, if any. Neutron monitoring is especially necessary in view of the fact that the radiation weighting factor for neutron is much higher than gamma rays and also it varies with energy. Radiological Physics and Advisory Division is involved in monitoring of personnel working in neutron fields. Around 2100 workers from 70 institutions (DAE and Non-DAE) are monitored on a quarterly basis. Neutron personnel monitoring, carried out in the country is based on Solid State Nuclear Track Detection (SSNTD) technique. In this technique, neutrons interact with hydrogen in CR-39 polymer to produce recoil protons. These protons create damages in the polymer, which are enlarged and appear as tracks when subjected to electrochemical etching (ECE). These tracks are counted in an optical system to evaluate the neutron dose. The neutron dosimetry system based on SSNTD has undergone a significant development, since it was started in 1990. The development includes upgradation of image analysis system for counting tracks, introduction of chemical etching (CE) at elevated temperatures for evaluation of dose equivalents above 10 mSv and use of carbon laser for cutting of CR-39 detectors. The entire dose evaluation process has been standardized, which includes calibration and performance tests

  15. Response of CR-39 based personnel neutron dosemeter in terms of directional dose equivalent, in free air and on phantom

    International Nuclear Information System (INIS)

    Pal, Rupali R.; Sathian, Deepa; Jayalakshmi, V.; Chougaonkar, M.P.

    2011-01-01

    CR-39 is the most sensitive of nuclear track detectors for protons and is recommended as an effective neutron dosimeter because of it's low threshold energy of 100 keV neutrons. The fraction of protons that gives detectable tracks in CR-39 depends on the energy of the proton angle of incidence and etching conditions. As a consequence the registration efficiency of neutrons in the CR-39 plastics used for neutron personnel monitoring is strongly influenced by the direction of radiation incidence. This paper presents the relative response of CR-39 at varying neutron incident angles, for 241 Am-Be neutron source spectra in free air and on ISO phantom, in terms of operational quantities. It is observed that the angular dependence of CR-39 for irradiations in air and on phantom is essentially the same indicating that the phantom does not affect the directional response of CR-39. (author)

  16. Calibrations of CR39 and Makrofol nuclear track detectors and search for exotic particles

    CERN Document Server

    Ambrosio, M; Auriemma, G; Bakari, D; Baldini, A; Barbarino, G C; Barish, B C; Battistoni, G; Becherini, Y; Bellotti, R; Bemporad, C; Bernardini, P; Bilokon, H; Bloise, C; Bower, C; Brigida, M; Bussino, S; Cafagna, F; Calicchio, M; Campana, D; Carboni, M; Caruso, R; Cecchini, S; Cei, F; Chiarella, V; Chiarusi, T; Choudhary, B C; Coutu, S; Cozzi, M; De Cataldo, G; De Marzo, C; De Mitri, I; De Vincenzi, M; Dekhissi, H; Derkaoui, J; Di Credico, A; Erriquez, O; Favuzzi, C; Forti, C; Fusco, P; Giacomelli, G; Giannini, G; Giglietto, N; Giorgini, M; Grassi, M; Grillo, A; Guarino, F; Gustavino, C; Habig, A; Hanson, K; Heinz, R; Iarocci, E; Katsavounidis, E; Katsavounidis, I; Kearns, E; Kim, H; Kumar, A; Kyriazopoulou, S; Lamanna, E; Lane, C; Levin, D S; Lipari, P; Longley, N P; Longo, M J; Loparco, F; Maaroufi, F; Mancarella, G; Mandrioli, G; Manzoor, S; Margiotta, A; Marini, A; Martello, D; Marzari-Chiesa, A; Matteuzzi, D; Mazziotta, M N; Michael, D G; Monacelli, P; Montaruli, T; Monteno, M; Mufson, S; Musser, J; Nicolò, D; Nolty, R; Orth, C; Osteria, G; Palamara, O; Patera, V; Patrizii, L; Pazzi, R; Peck, C W; Perrone, L; Petrera, S; Pistilli, P; Popa, V; Rainó, A; Reynoldson, J; Ronga, F; Rrhioua, A; Satriano, C; Scapparone, E; Scholberg, K; Sciubba, A; Serra, P; Sioli, M; Sirri, G; Sitta, M; Spinelli, P; Spinetti, M; Spurio, M; Steinberg, R; Stone, J L; Sulak, L R; Surdo, A; Tarle, G; Togo, V; Vakili, M; Walter, C W; Webb, R; 10.1016/S0920-5632(03)02249-7

    2003-01-01

    We present the final results of the search for exotic massive particles in the cosmic radiation performed with the MACRO underground experiment. Magnetic monopoles and nuclearites flux upper limits obtained with the CR39 nuclear track subdetector, the scintillation and streamer tube subdetectors are given. Searches at high altitude with the SLIM experiment are in progress.

  17. Calibration of CR-39 for radon-related parameters using sealed cup technique

    International Nuclear Information System (INIS)

    Abo-Elmagd, M.; Daif, M. M.

    2010-01-01

    Effective radium content, mass and areal radon exhalation rates of soil and rock samples are important radon-related parameters and can be used as a better indicator of radon risk. A sealed cup fitted to a CR-39 detector and to the sample under measurement is an advantageous passive device for the measurement of these parameters. The main factors affecting the results are the detector calibration factor and the sample weight. The results of an active technique (Lucas cell) and the CR-39 detector have been found to be correlated resulting in a reliable detector calibration factor. The result illustrates the dependence of the CR-39 calibration factor with the sample weight which is difficult to use in practice, because each sample weight has its own calibration factor of CR-39. It is reported to demonstrate the advantage of a back diffusion correction. After correcting the results for back diffusion effects, one obtains an approximately constant calibration factor for the sample volumes up to one-third the total sealed cup volume. For this condition the calibration factor is equal to 0.237 track cm -2 per Bq m -3 d with about 1% uncertainty. (authors)

  18. Effects of additives and impurities on the properties of CR-39 neutron dosimeters

    International Nuclear Information System (INIS)

    Tarle, G.

    1982-01-01

    Several problems have plagued users of commercial CR-39 for neutron dosimetry work. Large variations in sensitivity have been observed in samples received from different manufacturers, from different batches from the same manufacturer and even within a given sheet. The latter variations have taken several forms. Clear etching regions of lower sensitivity near the gasket and sometimes extending well away from the gasket in drip-like patterns have been observed. Large demarcated patches of differing sensitivity and sensitivity variations with depth have been found in many commercial samples of CR-39. In addition, we have observed a general roughening of the post-etch surface and a patchiness of bulk etching associated with contact patterns of adjacent sheets, which have been stored for extended (greater than or equal to 6 mos) periods of time. All of these problems combine to make commercially available CR-39 unreliable as a neutron dosimeter. In an attempt to identify and correct the causes of these problems, a systematic study of the effects of additives, impurities and manufacturing conditions on the uniformity of CR-39 track detectors has been undertaken, and is reported in this paper

  19. Annealing effects on the charged particles registration characteristic of the CR-39 traces solid detector

    International Nuclear Information System (INIS)

    Correa, M.M.

    1989-10-01

    CR-39 trace solid detectors samples, previously exposed to alpha particles and fission fragments from a Cf-252 source, were submitted to a annealing treatment to study his effects on the characteristics of charged particle traces registration. (L.C.J.A.)

  20. Relation between the size of fog droplets and their contact angles with CR39 surfaces

    International Nuclear Information System (INIS)

    Grosu, G; Andrzejewski, L; Veilleux, G; Ross, G G

    2004-01-01

    The formation of fog on CR39 surfaces has been studied. Water droplets form fog coalesce with time, especially during the first 20 s at the beginning of the formation of fog. Consequently, their mean diameter increases. Formation of fog being related to the wettability of the surfaces, the latter has been increased by the implantation of Ar ions into CR39 surfaces under an oxygen partial pressure. A very wetting CR39 surface with advancing (ACA) and receding (RCA) contact angles below 5 deg. has been obtained with an implantation dose of 1.28x10 17 Ar + cm -2 . In this condition, no formation of fog was observed. Characterization using x-ray photoelectron spectroscopy has shown that the molecular structure of CR39 is strongly modified by Ar + implantation, which would be responsible for the increase in wettability. Unfortunately, both ACA and RCA increase with time, which is called ageing, and the formation of fog is again observed. The diameter and concentration of water droplets forming fog have been plotted against the contact angle. These plots show that no formation of fog occurs for ACA 15 He + cm -2 and an energy of 2 keV, sufficient to push the ions deeper than the Ar depth profile, delays the ageing effect in such a way that ACA ≅ 40 deg. is reached after ∼2000 h and no formation of fog is observed during these first ∼2000 h

  1. Range to cone length relations for light ions in CR-39

    International Nuclear Information System (INIS)

    Gil, L.R.; Marques, A.

    1988-01-01

    Curves ''range x cone lenght'' and ''diameter x cone lenght'' are calculated for tracks left by low energy light ions in CR-39. The calculations cover ions from helium to iron and are performed for 6.25 N NaOH at 70 0 C and a standard etching time but can be easily extended to other etching conditions. (author) [pt

  2. Efficient alpha particle detection by CR-39 applying 50 Hz-HV electrochemical etching method

    International Nuclear Information System (INIS)

    Sohrabi, M.; Soltani, Z.

    2016-01-01

    Alpha particles can be detected by CR-39 by applying either chemical etching (CE), electrochemical etching (ECE), or combined pre-etching and ECE usually through a multi-step HF-HV ECE process at temperatures much higher than room temperature. By applying pre-etching, characteristics responses of fast-neutron-induced recoil tracks in CR-39 by HF-HV ECE versus KOH normality (N) have shown two high-sensitivity peaks around 5–6 and 15–16 N and a large-diameter peak with a minimum sensitivity around 10–11 N at 25°C. On the other hand, 50 Hz-HV ECE method recently advanced in our laboratory detects alpha particles with high efficiency and broad registration energy range with small ECE tracks in polycarbonate (PC) detectors. By taking advantage of the CR-39 sensitivity to alpha particles, efficacy of 50 Hz-HV ECE method and CR-39 exotic responses under different KOH normalities, detection characteristics of 0.8 MeV alpha particle tracks were studied in 500 μm CR-39 for different fluences, ECE duration and KOH normality. Alpha registration efficiency increased as ECE duration increased to 90 ± 2% after 6–8 h beyond which plateaus are reached. Alpha track density versus fluence is linear up to 10 6  tracks cm −2 . The efficiency and mean track diameter versus alpha fluence up to 10 6  alphas cm −2 decrease as the fluence increases. Background track density and minimum detection limit are linear functions of ECE duration and increase as normality increases. The CR-39 processed for the first time in this study by 50 Hz-HV ECE method proved to provide a simple, efficient and practical alpha detection method at room temperature. - Highlights: • Alpha particles of 0.8 MeV were detected in CR-39 by 50 Hz-HV ECE method. • Efficiency/track diameter was studied vs fluence and time for 3 KOH normality. • Background track density and minimum detection limit vs duration were studied. • A new simple, efficient and low-cost alpha detection method

  3. Detection of heavy nuclei in the plastic track detector CR-39

    International Nuclear Information System (INIS)

    Fumuro, F.; Ihara, R.; Ohta, I.; Sato, Y.; Tezuka, I.; Tasaka, S.; Sugimoto, H.

    1982-01-01

    Relativistic cosmic ray nuclei were detected in an emulsion chamber composed of a pile of solid state track detectors (CR-39) and the emulsion plates. The 460 heavy nuclei were observed by scanning of emulsion and CR-39 plastic plates. The normalized track etch rate (Vsub(t)/Vsub(b))-1 for relativistic iron group was measured as 1.3+-0.05 and bulk etch rate Vsub(b) as 1.63+-0.08 μm/hour after 32 hours etch in 6.8 N NaOH at 70 0 C. The charge detection threshold was obtained to be Z=6 for β=1 with the dip angle larger than 75 degrees. The charge resolution was estimated to be Δ Z=0.7 for iron, and Δ Z=0.4 for magnesium and silicon nuclei

  4. Angular and dose dependence of CR-39 neutron response for shape-selected tracks

    CERN Document Server

    Tam, N C; Lakosi, L

    1999-01-01

    A shape selection method corresponding to an energy discrimination was used to eliminate unwanted events disturbing evaluation of CR-39 detectors in detecting tracks induced by particles both of perpendicular and oblique incidence. The angular dependence of the response was examined, detecting fast neutrons from sup 2 sup 5 sup 2 Cf with shape selection technique at various angles and distances. Also, the CR-39 track detectors with the sup 2 sup 5 sup 2 Cf source were exposed to high gamma-intensity of a sup 6 sup 0 Co irradiation facility in the range 0.1 to 4.5 kGy, similar to the exposures inside spent fuel assemblies. Using the two functions the lower limit of burnup could be determined by the method.

  5. The possibility of using plastic detectors CR-39 as UV dosimeters

    International Nuclear Information System (INIS)

    Shweikani, R.; Raja, G.; Sawaf, A.A.

    2004-01-01

    The effects of solar ultraviolet (SUV) and ultraviolet type A (UVA) produced by a solar UV simulator on CR-39 detectors were studied. This was done using three techniques: 1 - Alpha tracks diameters and tracks densities, 2 - UV-Vis spectrometry and 3 - FTIR spectrometry. The detectors were divided into two groups, the first was exposed to UV and then to alpha particles, the second group was exposed to alpha particles first and then to UV. The results showed that the effect of UVA on CR-39 was not clear using the three techniques. While, the effect of SUV was clear when using UV-Vis and FTIR spectrometric, and not clear when using track parameters. (author)

  6. The possibility of using plastic detectors CR-39 as UV dosimeters

    International Nuclear Information System (INIS)

    Shweikani, R.; Raja, G.; Sawaf, A.A.

    2002-01-01

    The effects of solar ultraviolet (SUV) and ultraviolet type A (UVA) produced by a solar UV simulator on CR-39 detectors were studied. This was done using three techniques: 1 - Alpha tracks diameters and tracks densities, 2 - UV-Vis spectrometry and 3 - FTIR spectrometry. The detectors were divided into two groups, the first was exposed to UV and then to alpha particles, the second group was exposed to alpha particles first and then to UV. The results showed that the effect of UVA on CR-39 was not clear using the three techniques. While, the effect of SUV was clear when using UV-Vis and FTIR spectrometric, and not clear when using track parameters

  7. Bulk etching characteristics of CR-39 track detectors in hydroxide solutions

    International Nuclear Information System (INIS)

    Fonseca, E.S. da; Knoefel, T.M.J.; Tavares, O.A.P.

    1983-01-01

    A systematic study of the bulk etch rate of CR-39 track detectors in KOH and NaOH aqueous solutions is presented. A number of unirradiated and non-thermally treated CR-39 samples were chemically attacked in KOH and NaOH solutions of concentration and temperature in the range 2-10 N and 50-90 0 C, respectively. From measurements of the thickness of layers removed as a function of the etching time, the bulk etch rate υ β and the induction time T ο for surface removal were obtained for each etching condition. For both NaOH and KOH solution the activation energy of the process was derived as E = 0.76 ± 0.05 eV. It was observed that the induction time decreases both with increasing normality and temperature of the solution. (author) [pt

  8. Effect of oxygen pressure on sensitivity of CR-39 used for astronauts radiation dosimetry

    International Nuclear Information System (INIS)

    Murai, T.; Yabe, S.; Nagamatsu, A.; Tawara, H.; Kumagai, H.; Miyazawa, Y.; Kitajo, K.; Kodaira, S.; Yasuda, N.

    2006-01-01

    The personal radiation dosimeters for astronauts are exposed to low-pressure oxygen gas (0.29 atmospheres) during extra-vehicle activities. CR-39 plastic track detectors are one of the typical passive dosimeters for space radiation monitoring. We investigated change in track formation sensitivity of the antioxidant-doped CR-39 plastic with which oxygen gas comes in contact at different pressures up to 2 atmospheres for 1h to 10 days. The oxygen effect on sensitivity was measured for the C, Si and Fe ions (10-200 keV/μm) from the HIMAC heavy ion accelerator. The sensitivity is obviously sensitive to oxygen pressure at heavy-ion exposures, but not sensitive to the experience of oxygen atmosphere before and after the ion exposures. The maximum sensitivity is obtained at 0.29 atmospheres. The present experimental data suggested that the effect depends on LET of incident particles. (author)

  9. Determination of exhalation rate of radon from walls and indoor radon by CR-39 detectors

    International Nuclear Information System (INIS)

    Vasidov, A.; Tillaev, T.S.

    2007-01-01

    Full text: The knowledge of true value exhalation rate of radon gas from building materials represents scientific and practical interest in environmental radiation protection. This point of view in the paper exhalation rate of radon gas from building materials and a surface of walls with different constructions were determined by detectors CR-39. The values of the exhalation rate of radon per unit area of the granite, concrete, fired and unfired bricks, sand, cement, alabaster varied 0.091 - 0.1 Bq·m -2 ·h -1 . The surface of walls of dwellings constructed from different building materials the exhalation rate of radon are within in limits of 0.083-1.12 Bq·m -2 ·h -1 . Were measurements with CR-39 detectors a level of radon within 50-520 Bq/m 3 in air of rooms constructed of the different building materials

  10. Study of the characteristics of ionizing particles record of CR-39 track detectors

    International Nuclear Information System (INIS)

    Brandao, Luis Eduardo Barreira

    1983-01-01

    The bulk and track etching proprieties of a new Solid State Nuclear Track Detector CR-39 were investigated under different etching conditions. The discussion is based on results obtained using aqueous solutions of KOH with addition of alcoholic solvent to aqueous solutions. It was found that track registration sensitivity can be dramatically changed by using the proper chemical treatment. A method to enlarge and dye etch tracks to be viewed by simple projection on a screen is discussed. The applications of CR-39 in neutron fluence measurements are shown. Graphs are presented of the densities of the registered traces by the detector as a function of etch time both for samples with and without a polycarbonate radiator. (author)

  11. Vacuum treatment of CR-39 for the reduction of background in neutron induced autoradiography of boron

    International Nuclear Information System (INIS)

    Freyer, K.; Treutler, H.C.; Dietze, K.; Hunyadi, I.; Csige, I.; Somogyi, G.

    1991-01-01

    The influence of etching time and vacuum processing before, during, and after neutron irradiation on the ''signal/noise'' ratio of the neutron induced autoradiography of boron using CR-39 track detectors has been investigated. The neutron irradiation was carried out in a vacuum chamber using the Cf-252 neutron source of the Central Institute of Isotope and Radiation Research at Leipzig. Hungarian-made CR-39 type track detectors, MA-ND/p and MA-ND/α, produced in different years, are compared. After a few hours of 2 kPa (about 10 -2 Torr) vacuum treatment, the ''signal/noise'' ratio for boron determination is improved remarkably in most cases of the detector and etching-time combinations used. (author)

  12. Vacuum treatment of CR-39 for the reduction of background in neutron induced autoradiography of boron

    Energy Technology Data Exchange (ETDEWEB)

    Freyer, K.; Treutler, H.C.; Dietze, K. (Central Inst. of Isotope and Radiation Research, Leipzig (Germany, F.R.)); Hunyadi, I.; Csige, I.; Somogyi, G. (Magyar Tudomanyos Akademia, Debrecen (Hungary). Atommag Kutato Intezete)

    1991-01-01

    The influence of etching time and vacuum processing before, during, and after neutron irradiation on the ''signal/noise'' ratio of the neutron induced autoradiography of boron using CR-39 track detectors has been investigated. The neutron irradiation was carried out in a vacuum chamber using the Cf-252 neutron source of the Central Institute of Isotope and Radiation Research at Leipzig. Hungarian-made CR-39 type track detectors, MA-ND/p and MA-ND/{alpha}, produced in different years, are compared. After a few hours of 2 kPa (about 10{sup -2} Torr) vacuum treatment, the ''signal/noise'' ratio for boron determination is improved remarkably in most cases of the detector and etching-time combinations used. (author).

  13. Development of hybrid track detector using CR39 and photographic plate

    International Nuclear Information System (INIS)

    Kuge, K.; Endo, Y.; Hayashi, K.; Iwakiri, S.; Hasegawa, A.; Yasuda, N.; Kumagai, H.

    2005-01-01

    To improve the hybrid track detector using both CR39 and silver halide photography the gold deposition development technique was applied to this. Nuclear tracks composed of gold clusters were obtained. This method has several advantages; 1. no filament formation, 2. easy control of the cluster size owing to the independence of the size of silver halide grain, 3. easy treatment of the waste solution of developer. (author)

  14. Development of optical monitor of alpha radiations based on CR-39.

    Science.gov (United States)

    Joshirao, Pranav M; Shin, Jae Won; Vyas, Chirag K; Kulkarni, Atul D; Kim, Hojoong; Kim, Taesung; Hong, Seung-Woo; Manchanda, Vijay K

    2013-11-01

    Fukushima accident has highlighted the need to intensify efforts to develop sensitive detectors to monitor the release of alpha emitting radionuclides in the environment caused by the meltdown of the discharged spent fuel. Conventionally, proportional counting, scintillation counting and alpha spectrometry are employed to assay the alpha emitting radionuclides but these techniques are difficult to be configured for online operations. Solid State Nuclear Track Detectors (SSNTDs) offer an alternative off line sensitive technique to measure alpha emitters as well as fissile radionuclides at ultra-trace level in the environment. Recently, our group has reported the first ever attempt to use reflectance based fiber optic sensor (FOS) to quantify the alpha radiations emitted from (232)Th. In the present work, an effort has been made to develop an online FOS to monitor alpha radiations emitted from (241)Am source employing CR-39 as detector. Here, we report the optical response of CR-39 (on exposure to alpha radiations) employing techniques such as Atomic Force Microscopy (AFM) and Reflectance Spectroscopy. In the present work GEANT4 simulation of transport of alpha particles in the detector has also been carried out. Simulation includes validation test wherein the projected ranges of alpha particles in the air, polystyrene and CR-39 were calculated and were found to agree with the literature values. An attempt has been further made to compute the fluence as a function of the incidence angle and incidence energy of alphas. There was an excellent correlation in experimentally observed track density with the simulated fluence. The present work offers a novel approach to design an online CR-39 based fiber optic sensor (CRFOS) to measure the release of nanogram quantity of (241)Am in the environment. © 2013 Elsevier Ltd. All rights reserved.

  15. Exposure of CR39 Stacks to Oxygen and Sulphur Beams at the CERN-SPS

    CERN Multimedia

    2002-01-01

    We plan to expose 8 stacks of CR39 sheets to oxygen and sulphur ions of 60 and 200~GeV at the CERN-SPS.\\\\ \\\\ The main purpose of the exposures is the calibration of the CR39 sheets used for a large area experimental search for magnetic monopoles at the Gran Sasso Laboratory (experiment MACRO). \\\\ \\\\ The stacks have 20~layers of CR39, each layer 13~cm~x~7~cm and 1.4~mm thick. A copper absorber is located after the first 6 layers. \\\\ \\\\ We require exposures of about 2000 tracks per cm$^2$ over the entire area of the stack with a uniform illumination. The standard beam used for the emulsion experiments is normally adequate for this purpose.\\\\ \\\\ We have performed one exposure to sulphur ions. The etched tracks have been measured automatically with the Elbeck image analyser system. We measured the incoming sulphur ions as well as the nuclear fragments produced in the copper absorber. Clean separation among the peaks due to the various fragments is obtained (there is no indication of nuclei with fractional electri...

  16. Directional Track Selection Technique in CR39 SSNTD for lowyield reaction experiments

    Science.gov (United States)

    Ingenito, Francesco; Andreoli, Pierluigi; Batani, Dimitri; Bonasera, Aldo; Boutoux, Guillaume; Burgy, Frederic; Cipriani, Mattia; Consoli, Fabrizio; Cristofari, Giuseppe; De Angelis, Riccardo; Di Giorgio, Giorgio; Ducret, Jean Eric; Giulietti, Danilo; Jakubowska, Katarzyna

    2018-01-01

    There is a great interest in the study of p-11B aneutronic nuclear fusion reactions, both for energy production and for determination of fusion cross-sections at low energies. In this context we performed experiments at CELIA in which energetic protons, accelerated by the laser ECLIPSE, were directed toward a solid Boron target. Because of the small cross-sections at these energies the number of expected reactions is low. CR39 Solid-State Nuclear Track Detectors (SSNTD) were used to detect the alpha particles produced. Because of the low expected yield, it is difficult to discriminate the tracks due to true fusion products from those due to natural background in the CR39. To this purpose we developed a methodology of particle recognition according to their direction with respect to the detector normal, able to determine the position of their source. We applied this to the specific experiment geometry, so to select from all the tracks those due to particles coming from the region of interaction between accelerated protons and solid boron target. This technique can be of great help on the analysis of SSNTD in experiments with low yield reactions, but can be also generally applied to any experiment where particles reach the track detector with known directions, and for example to improve the detection limit of particle spectrometers using CR39.

  17. Fast neutron dosimetry using CR-39 track detectors with polyethylene as radiator

    International Nuclear Information System (INIS)

    Castillo, F.; Espinosa, G.; Golzarri, J.I.; Osorio, D.; Rangel, J.; Reyes, P.G.; Herrera, J.J.E.

    2013-01-01

    The chemical etching parameters (etching time, temperature, normality of etchant, etc.) for the use of CR-39 (allyl diglycol carbonate – Lantrack ® ) as a fast neutron dosimeter have been optimized. The CR-39 chips, placed under a 1.5 mm polyethylene radiator, were exposed for calibration to an 241 Am-Be source at different time intervals for a given neutron fluence. After several chemical etching processes of the detectors with different conditions, the optimum characteristics for the chemical etching were found at 6N KOH solution, 60 ± 1 °C, for 12 h. An accurate relationship between the dose and fluence calculations was obtained as a function of the track density. - Highlights: ► Optimum etching time for fast neutron irradiated CR-39 track detectors is found. ► Relationship between dose and fluence obtained as a function of the track density. ► Results are consistent with those reported elsewhere, and extend the dose range

  18. Characterization of CR 39 nuclear track detector for use as a radon/thoron dosemeter

    International Nuclear Information System (INIS)

    Kandaiya, S.

    1988-02-01

    For the estimation of radon, thoron and their short-lived daughter products in air radon diffusion chambers with passive α-track etch detectors have been used. The report describes the properties of CR 39 track etch detectors in particular with respect to the spectrometric detection of α-particles in the energy range up to 8.77 MeV using chemical and a combination of chemical-electrochemical etching technique. In order to optimize the etching conditions for an α-energy discrimination in the energy range up to 8.77 MeV, the ECE track size diameter and the track density have been investigated as a function of the chemical pre-etching time using three electrical field strengths. In a mixed α-spectrum the contributions of various α-particles with energies between 4.6 to 8.77 MeV have been determined experimentally in CR 39 and compared with the spectral measurement using a surface barrier detector and the same irradiation geometry. Beside CR 39 detectors etched chemically and electrochemically, in addition surface barrier detectors and a Monte Carlo calculation have been used to evaluate the α-energy spectrum for thoron and its daughter products emitted by α-decays in the air volume and the plate-out of daughters at the inner surface on the diffusion chamber. (orig./HP) [de

  19. Coherent light scattering by nuclear etched tracks in the PADC (a form of CR-39)

    Energy Technology Data Exchange (ETDEWEB)

    Groetz, J.E.; Chambaudet, A. [Universite de Franche-Comte, Besancon (France). Lab. de Microanalyses Nucleaires; Lacourt, A. [Laboratoire d`Optique P.M. Duffieux, UMR 6603 CNRS, Universite de Franche-Comte, 16 route de Gray, 25030 Besancon Cedex (France)

    1998-08-01

    A new kind of measurement has been proposed to improve the reading of the solid state nuclear track detector CR-39. This method is based on coherent light scattering (He-Ne laser) by etched proton tracks, and is complementary to observation under an optical microscope and reading by optical density of the CR-39. The irradiated and chemically etched CR-39 sample is illuminated by a laser beam under a normal incidence angle. The light intensity diffracted by the tracks beyond the sample - defined with the bi-directional transmissive distribution functions - is measured with a photodiode. Thus, the bi-directional transmissive distribution functions depend on the characteristics of the irradiation, namely the track density, track sizes and orientations. We have performed a track light diffraction model calculation through the use of the Fraunhofer diffraction, Babinet`s principle and the spatial coherence and incoherence. We compared calculations and experimental results for the different shapes of tracks: conical, oblique and spherical-shaped. (orig.) 14 refs.

  20. Coherent light scattering by nuclear etched tracks in the PADC (a form of CR-39)

    International Nuclear Information System (INIS)

    Groetz, J.E.; Chambaudet, A.

    1998-01-01

    A new kind of measurement has been proposed to improve the reading of the solid state nuclear track detector CR-39. This method is based on coherent light scattering (He-Ne laser) by etched proton tracks, and is complementary to observation under an optical microscope and reading by optical density of the CR-39. The irradiated and chemically etched CR-39 sample is illuminated by a laser beam under a normal incidence angle. The light intensity diffracted by the tracks beyond the sample - defined with the bi-directional transmissive distribution functions - is measured with a photodiode. Thus, the bi-directional transmissive distribution functions depend on the characteristics of the irradiation, namely the track density, track sizes and orientations. We have performed a track light diffraction model calculation through the use of the Fraunhofer diffraction, Babinet's principle and the spatial coherence and incoherence. We compared calculations and experimental results for the different shapes of tracks: conical, oblique and spherical-shaped. (orig.)

  1. Suitability of CR-39 dosimeters for personal dosimetry around CANDU reactors

    International Nuclear Information System (INIS)

    Cross, W.G.

    1992-08-01

    The capabilities and limitations of CR-39 damage track detectors have been evaluated for their use as personal neutron dosimeters around CANDU reactors. Since the energy response is a critical characteristic, the neutron energy spectra expected within CANDU containments were studied. In the boiler rooms, around the moderator cooling systems, and in most of the fueling machine vaults, the spectra vary considerably, but the majority of the dose is expected to be delivered by neutrons above 80 keV, the approximate threshold for electrochemically-etched CR-39 detectors. In the Pickering A fueling machine vault, and in areas in other stations to which neutrons from reactors have been multiply scattered, lower energy neutrons may be important. In nearly all areas where people work, it appears that working times will be limited by gamma rays rather than by neutrons. The characteristics of other neutron dosimeters - bubble and superheated drop detectors, albedo detectors, and Si real-time detectors - were also reviewed. For workers who typically receive neutron doses that are small compared with regulatory limits, CR-39 is the most suitable available dosimeter for demonstrating compliance. All single dosimeters have poor angular response over the range 0 to 180 degrees because of the shielding of the body. Albedo and Si detectors have particularly poor energy responses over the energy range of importance. Bubble and superheated drop detectors have the advantages of immediate readout and high sensitivity, but the disadvantages of inability to integrate doses over a long period, temperature dependence, very limited range and higher cost. (Author) (110 refs., 45 figs.)

  2. Testing Novel CR-39 Detector Deployment System For Identification of Subsurface Fractures, Soda Springs, ID

    Energy Technology Data Exchange (ETDEWEB)

    McLing, Travis [Idaho National Lab. (INL), Idaho Falls, ID (United States); Carpenter, Michael [Idaho National Lab. (INL), Idaho Falls, ID (United States); Brandon, William [Idaho National Lab. (INL), Idaho Falls, ID (United States); Zavala, Bernie [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2015-06-01

    The Environmental Protection Agency (EPA) has teamed with Battelle Energy Alliance, LLC (BEA) at Idaho National Laboratory (INL) to facilitate further testing of geologic-fracture-identification methodology at a field site near the Monsanto Superfund Site located in Soda Springs, Idaho. INL has the necessary testing and technological expertise to perform this work. Battelle Memorial Institute (BMI) has engaged INL to perform this work through a Work for Others (WFO) Agreement. This study continues a multi-year collaborative effort between INL and EPA to test the efficacy of using field deployed Cr-39 radon in soil portals. This research enables identification of active fractures capable of transporting contaminants at sites where fractures are suspected pathways into the subsurface. Current state of the art methods for mapping fracture networks are exceedingly expensive and notoriously inaccurate. The proposed WFO will evaluate the applicability of using cheap, readily available, passive radon detectors to identify conductive geologic structures (i.e. fractures, and fracture networks) in the subsurface that control the transport of contaminants at fracture-dominated sites. The proposed WFO utilizes proven off-the-shelf technology in the form of CR-39 radon detectors, which have been widely deployed to detect radon levels in homes and businesses. In an existing collaborative EPA/INL study outside of this workscope,. CR-39 detectors are being utilized to determine the location of active transport fractures in a fractured granitic upland adjacent to a landfill site at the Fort Devens, MA that EPA-designated as National Priorities List (NPL) site. The innovative concept of using an easily deployed port that allows the CR-39 to measure the Rn-222 in the soil or alluvium above the fractured rock, while restricting atmospheric Rn-222 and soil sourced Ra from contaminating the detector is unique to INL and EPA approach previously developed. By deploying a series of these

  3. Regular self-microstructuring on CR39 using high UV laser dose

    International Nuclear Information System (INIS)

    Parvin, P.; Refahizadeh, M.; Mortazavi, S.Z.; Silakhori, K.; Mahdiloo, A.; Aghaii, P.

    2014-01-01

    The UV laser induced replicas in the form of self-lining microstructures are created by high dose (with high fluence) ArF laser irradiation on CR39. Microstructures as the self-induced contours, in the form of concentric circles, appear when the laser fluence is well above the ablation threshold. It leads to the regular periodic parallel lines, i.e. circles with large radii having spatial separation 100–200 nm and line width 300–600 nm, where the number of shots increases to achieve higher UV doses. The surface wettability is also investigated after laser texturing to exhibit that a notable hydrophilicity takes place at high doses.

  4. A study of CR-39 plastic charged-particle detector replacement by consumer imaging sensors

    Energy Technology Data Exchange (ETDEWEB)

    Plaud-Ramos, K. O.; Freeman, M. S.; Wei, W.; Guardincerri, E.; Bacon, J. D.; Cowan, J.; Durham, J. M.; Huang, D.; Gao, J.; Hoffbauer, M. A.; Morley, D. J.; Morris, C. L.; Poulson, D. C.; Wang, Zhehui, E-mail: zwang@lanl.gov [Los Alamos National Laboratory, Los Alamos, New Mexico 87545 (United States)

    2016-11-15

    Consumer imaging sensors (CIS) are examined for real-time charged-particle detection and CR-39 plastic detector replacement. Removing cover glass from CIS is hard if not impossible, in particular for the latest inexpensive webcam models. We show that $10-class CIS are sensitive to MeV and higher energy protons and α-particles by using a {sup 90}Sr β-source with its cover glass in place. Indirect, real-time, high-resolution detection is also feasible when combining CIS with a ZnS:Ag phosphor screen and optics. Noise reduction in CIS is nevertheless important for the indirect approach.

  5. Etching characteristics of a CR-39 track detector at room temperature in different etching solutions

    International Nuclear Information System (INIS)

    Dajko, G.

    1991-01-01

    Investigations were carried out to discover how the etching characteristics of CR-39 detectors change with varying conditions of the etching process. Measurements were made at room temperature in pure NaOH and KOH solutions; in different alcoholic KOH solutions (PEW solution, i.e. potassium hydroxide, ethyl alcohol, water); and in NaOH and KOH solutions containing different additives. The bulk etching rate of the detector (V B ) and the V (= V T /V B ) function, i.e. track to bulk etch rates ratio, for 6.1 MeV α-particles, were measured systematically. (author)

  6. A study of CR-39 track response to charged particles from NOVA implosions

    International Nuclear Information System (INIS)

    Phillips, T.W.; Cable, M.D.; Hicks, D.G.; Li, C.K.; Petrasso, R.D.; Seguin, F.H.

    1996-01-01

    We have exposed CR-39 track recording material to a number of NOVA implosions. Radiation from the implosion passed through an array of ranging filters, which aided identification of the incident particles and their energies. The etching procedure was calibrated by including a piece of track exposed to DD protons from a small accelerator. For the same shots, we quantitatively compare the DD neutron yield with the DD proton yield determined from the track. In DT implosions, tracks produced by neutron interactions prevent observation of charged-particle tracks that are produced by the processes of knock-on, secondary or tertiary fusion

  7. Interaction mean free path measurements for relativistic heavy ion fragments using CR39 plastic track detectors

    International Nuclear Information System (INIS)

    Drechsel, H.; Brechtmann, C.; Dreute, J.; Sonntag, S.; Trakowski, W.; Beer, J.; Heinrich, W.

    1984-01-01

    This paper describes an experiment measuring the interaction mean free paths for charge changing nuclear collisions of relativistic heavy ion fragments. We use a stack of CR39 plastic nuclear track detectors that was irradiated with 1.8 GeV/nucleon 40 Ar ions at the Berkeley Bevalac. About 1.5 x 10 7 etch cones were measured in this experiment using an automatic measuring system. By tracing the etch cones over successive plastic foils the particle trajectories in the stack were reconstructed. For 14185 trajectories with 6444 nuclear collisions of fragments with charge 9-15 the interaction mean free path in the plastic was determined. (orig.)

  8. The development of an automatic scanning method for CR-39 neutron dosimeter

    International Nuclear Information System (INIS)

    Tawara, Hiroko; Miyajima, Mitsuhiro; Sasaki, Shin-ichi; Hozumi, Ken-ichi

    1989-01-01

    A method of measuring low level neutron dose has been developed with CR-39 track detectors using an automatic scanning system. It is composed of the optical microscope with a video camera, an image processor and a personal computer. The focus point of the microscope and the X-Y stage are controlled from the computer. The minimum detectable neutron dose is estimated at 4.6 mrem in the uniform field of neutron with equivalent energy spectrum to Am-Be source from the results of automatic measurements. (author)

  9. Use of Image Pro Plus for counting of α particles tracks in CR-39

    International Nuclear Information System (INIS)

    Miranda, Marcia Valeria F.E. Sa; Crispim, Verginia Reis

    2011-01-01

    This paper measured the radon radiations present in NORM samples, through the diffusion chambers which contained a nuclear track detector (CR-39). For automatic counting of those tracks the computer program Image Pro plus was used. This paper reports the application of Image Pro plus for counting the nuclear tracks, coming from the radon radiation present in NORM samples. As the radiation rate of 222 Rn if proportional to the number of these tracks, the methodology allowed to compare the levels of contamination of the analysed samples. Also, tables and graphics are presented with counting results referring to the stage of validation of Image Pro plus

  10. Autoradiographic measurement of low concentrations of alpha-active nuclides using CR-39 track detectors

    International Nuclear Information System (INIS)

    Freyer, K.; Dietze, K.; Weisse, S.; Kummer, G.

    1991-01-01

    An autoradiographic method for the determination of alpha emission rates from plastic packaging materials for VLSI silicon memory devices based on long-time exposure of the samples on CR-39 detectors has been tested. The lower limit of detection will be strongly influenced by the background of the detector material and amounts at times to 0.002 alpha particles cm -2 h -1 after 200 days exposure. A mathematical method for the interpretation of very low track densities is discussed. The first results of its application are presented. (author)

  11. Detection of fission fragments and alpha particles using the solid trace detector CR-39

    International Nuclear Information System (INIS)

    Santos, R.C.

    1988-01-01

    The technique of detecting charged particles using the solid track detector CR-39 is employed to establish some characteristics of fission fragments and alpha particles emitted from a Cf-252 source. Results are presented and discussed on the following aspects i) distribution of the track diameters; ii) variations on the track diameters to the chemical attack; iii) variations of the chemical attack velocity with respect to concentration and temperature. iv) activation energy of the developping process; v) induction time; vi) critical angle and efficiency on track developping. (A.C.A.S.) [pt

  12. Status of development in the field of Cr-39 track detectors

    International Nuclear Information System (INIS)

    Somogyi, G.

    1982-01-01

    The present situation concerning the manufacture and etching characteristics of the CR-39 nuclear track detector is surveyed. Especial attention is paid to the trends in research and to the outstanding questions related to the subject. The requirements and procedures in connection with the manufacture of high-quality, thick and thin detector foils are discussed. The main bulk and track etching characteristics are presented, involving the effects of various environmental parameters as well. A statistical account of the typical directions in application is given. (author)

  13. Alpha activity of 190 Pt isotope measured with CR-39 track detector

    International Nuclear Information System (INIS)

    Tavares, O.A.P.; Terranova, M.L.

    1996-11-01

    A new method to measure alpha activity of long-lived radioisotopes is reported. The method consists basically in using CR-39 track detectors in close contact with thick samples of the radioelement to be investigated. Accordingly, a long-term exposure experiment has been performed using metallic sheets of natural platinum to measure alpha activity of platinum 190 isotope. The half-life of platinum 190 has been obtained in good agreement with two recent theoretical half-life predictions. (author). 21 refs., 3 figs., 2 tabs

  14. High resolution alpha-autoradiography for measurement of 10B distribution in subcellular scale using CR-39 and AFM

    International Nuclear Information System (INIS)

    Amemiya, K.; Takahashi, H.; Yasuda, N.

    2000-01-01

    In order to measure 10 B distribution in tumor tissues for BNCT at subcellular scale, we have developed a new method for high resolution alpha-autoradiography using contact X-ray microscopy technique with CR-39 plastic track detectors. Sliced sections of boron-injected brain tumors in rats were mounted on CR-39 and irradiated with thermal neutrons at KUR. Then the samples were exposed to soft X-rays from a laser plasma source. After etching the CR-39 in NaOH solution for a short time (1-5 min.), transmission X-ray image of tumor cells appeared as relief on CR-39 surface, and could be observed with the atomic force microscopy (AFM). Very small etch pits of about 100 nm in diameter corresponding to particle tracks from 10 B(n, α) 7 Li reactions were also observed in the image simultaneously. This method provides an accurate distribution of 10 B inside the cell. (author)

  15. Response of CR-39 SSNTD to high energy neutrons using zirconium convertors - a Monte Carlo and experimental study

    International Nuclear Information System (INIS)

    Pal, Rupali; Sapra, B.K.; Bakshi, A.K.; Datta, D.; Biju, K.; Suryanarayana, S.V.; Nayak, B.K.

    2016-01-01

    Neutron dosimetry in ion accelerators is a challenging field as the neutron spectrum varies from thermal, to fast and high-energy neutrons usually extending beyond 20 MeV. Solid-state Nuclear Track Detectors (SSNTDs) have been increasingly used in numerous fields related to nuclear physics. Extensive work has also been carried out on determining the response characteristics of such detectors as nuclear spectrometers. In nuclear reaction studies, identification of reaction products according to their type and energy is frequently required. For normally incident particles, energy-dispersive track-diameter methods have become useful scientific tools using CR-39 SSNTD. CR-39 along with 1 mm polyethylene convertor can cover a neutron energy range from 100 keV to 10 MeV. The neutron interacts with the hydrogen in CR-39 producing recoil protons from elastic collisions. This detectable neutron energy range can be increased by modification in the radiator/convertor used along with CR-39. CR39 detectors placed in conjunction with judiciously chosen thicknesses of a polyethylene radiator and a lead absorber (or degrader) are used to increase energy range upto 19 MeV. A portable neutron counter has been proposed for high-energy neutron measurement with 1 cm thick Zirconium (Zr) as the converter outside a spherical HDPE shell of 7 inch diameter. Zr metal has been found to show (n,2n) cross section for energies above 10 MeV starting from 0.01 barns for 8 MeV upto 1 barns for 22 MeV. Above these energies, the experimental data is scarce. In this paper, Zr was used in conjunction with CR-39 which showed an enhancement of track density on the CR-39. This paper demonstrates the enhancement of neutron response using Zr on CR-39 with both theoretical and experimental studies

  16. Effect of argon ion implantation on the electrical and dielectric properties of CR-39

    International Nuclear Information System (INIS)

    Chawla, Mahak; Shekhawat, Nidhi; Goyal, Meetika; Gupta, Divya; Sharma, Annu; Aggarwal, Sanjeev

    2016-01-01

    The objective of the present work is to study the effect of 130 keV Ar"+ ions on the electrical and dielectric properties of CR-39 samples at various doses 5×10"1"4, 1×10"1"5 and 1×10"1"6 Ar"+ cm"−"2. Current-Voltage (I-V characteristics) measurements have been used to study the electrical properties of virgin and Ar"+ implanted CR-39 specimens. The current has been found to be increased with increasing voltage as well as with increasing ion dose. The dielectric spectroscopy of these specimens has been done in the frequency range of 100 kHz-100 MHz. The dielectric constant has been found to be decreasing whereas dielectric loss factor increases with increasing ion fluence. These kind of behavior observed in the implanted specimens indicate towards the formation of carbonaceous clusters due to the cross linking, chemical bond cleavage, formation of free radicals. The changes observed in the dielectric behavior have been further correlated with the structural changes observed through I-V characteristics.

  17. Long-term measurements of equilibrium factor with electrochemically etched CR-39 SSNTD

    International Nuclear Information System (INIS)

    Ng, F.M.F.; Nikezic, D.; Yu, K.N.

    2007-01-01

    Recently, our group proposed a method (proxy equilibrium factor method) using a bare LR 115 detector for long-term monitoring of the equilibrium factor. Due to the presence of an upper alpha-particle energy threshold for track formation in the LR 115 detector, the partial sensitivities to 222 Rn, 218 Po and 214 Po were the same, which made possible measurements of a proxy equilibrium factor F p that was well correlated with the equilibrium factor. In the present work, the method is extended to CR-39 detectors which have better-controlled etching properties but do not have an upper energy threshold. An exposed bare CR-39 detector is first pre-etched in 6.25 N NaOH solution at 70 o C for 6 h, and then etched electrochemically in a 6.25 N NaOH solution with ac voltage of 400 V (peak to peak) and 5 kHz applied across the detectors for 1 h at room temperature. Under these conditions, for tracks corresponding to incident angles larger than or equal to 50 deg., the treeing efficiency is 0% and 100% for incident energies smaller than and larger than 4 MeV, respectively. A simple method is then proposed to obtain the total number of tracks formed below the upper energy threshold of 4 MeV, from which the proxy equilibrium factor method can apply

  18. Experimental and Monte Carlo simulation studies of open cylindrical radon monitoring device using CR-39 detector

    Energy Technology Data Exchange (ETDEWEB)

    Rehman, Fazal-ur- E-mail: fazalr@kfupm.edu.sa; Jamil, K.; Zakaullah, M.; Abu-Jarad, F.; Mujahid, S.A

    2003-07-01

    There are several methods of measuring radon concentrations but nuclear track detector cylindrical dosimeters are widely employed. In this investigation, the consequence of effective volumes of the dosimeters on the registration of alpha tracks in a CR-39 detector was studied. In a series of experiments an optimum radius for a CR-39-based open cylindrical radon dosimeter was found to be about 3 cm. Monte Carlo simulation techniques hav been employed to verify the experimental results. In this context, a computer code Monte Carlo simulation dosimetry (MOCSID) was developed. Monte Carlo simulation experiments gave the optimum radius of the dosimeters as 3.0 cm. The experimental results are in good agreement with those obtained by Monte Carlo design calculations. In addition to this, plate-out effects of radon progeny were also studied. It was observed that the contribution of radon progeny ({sup 218}Po and {sup 214}Po) plated-out on the wall of the dosimeters increases with an increase of dosimeter radii and then decrease to 0 at a radius of about 3 cm if a point detector has been installed at the center of the dosimeter base. In the code MOCSID different types of random number generators were employed. The results of this research are very useful for designing an optimum size of radon dosimeters.

  19. Experimental and Monte Carlo simulation studies of open cylindrical radon monitoring device using CR-39 detector

    International Nuclear Information System (INIS)

    Rehman, Fazal-ur-; Jamil, K.; Zakaullah, M.; Abu-Jarad, F.; Mujahid, S.A.

    2003-01-01

    There are several methods of measuring radon concentrations but nuclear track detector cylindrical dosimeters are widely employed. In this investigation, the consequence of effective volumes of the dosimeters on the registration of alpha tracks in a CR-39 detector was studied. In a series of experiments an optimum radius for a CR-39-based open cylindrical radon dosimeter was found to be about 3 cm. Monte Carlo simulation techniques hav been employed to verify the experimental results. In this context, a computer code Monte Carlo simulation dosimetry (MOCSID) was developed. Monte Carlo simulation experiments gave the optimum radius of the dosimeters as 3.0 cm. The experimental results are in good agreement with those obtained by Monte Carlo design calculations. In addition to this, plate-out effects of radon progeny were also studied. It was observed that the contribution of radon progeny ( 218 Po and 214 Po) plated-out on the wall of the dosimeters increases with an increase of dosimeter radii and then decrease to 0 at a radius of about 3 cm if a point detector has been installed at the center of the dosimeter base. In the code MOCSID different types of random number generators were employed. The results of this research are very useful for designing an optimum size of radon dosimeters

  20. The influence of chemical etching time on efficiency of radon detection using CR-39

    International Nuclear Information System (INIS)

    Reway, Adriana P.; Kappke, Jaqueline; Narloch, Danielle C.; Del Claro, Flavia; Paschuk, Sergei A.; Correa, Janine N.

    2015-01-01

    Natural radiation is the principal source of human exposure to ionizing radiation. Radon is noble radioactive gas that emanates from the soil and rocks entering the atmosphere of dwellings where it could be accumulated. The inhalation of 222 Rn represents a significant health risk. Solid-State Nuclear Track Detectors (SSNTD) represents an efficient method for alpha particle detection and measurements of the activity concentration of 222 Rn. The aim of present work was to study the etching time impact on CR-39 efficiency in radon activity measurements. The investigation was performed using 80 CR-39 detectors, which were exposed to a source of radon. After the exposition, alpha particle tracks development was achieved by chemical etching using 6.25M NaOH solution and ethanol (2%) at 70°C. Etching alpha particle tracks were identified and counted manually using the optical microscope with magnification of 100x and glass overlay mask. The etching time ranged from 7 to 14 hours. The results show that there is an increase in the number of visible tracks with increased etching time. The number of traces obtained for 7 hours and 8 hours of revelation was 1430 +/- 90 and 2090 +/- 160, respectively. However, for etching time of 13 and 14 hours was not observed statistical increase in the number of visible tracks. The number of tracks in this situation was 3630 +/- 180 and 3870 +/- 160 to 13 and 14 hours etching. Thus, for assumed etching parameters, the etching optimal time was observed 14 hours. (author)

  1. Employment of the polycarbonates Makrofol-DE and CR-39 for neutron radiography

    International Nuclear Information System (INIS)

    Pereira, Marco Antonio Stanojev

    2000-01-01

    The track-etch method was employed for Neutron Radiography purposes. The solid state nuclear track detectors Makrofol-DE and CR-39 together with a natural boron converter screen have been used as imaging systems. In order to determine their radiographic characteristics, the imaging systems were irradiated up to neutron exposures around 6x10 10 /cm 2 in a radiography facility installed at the IEA-R1 Nuclear Research Reactor and the detectors developed between 2 and 65 minutes. The main goal of this work was determine the radiography conditions for which the best contrast and resolution are obtained at the image. These conditions are: - Makrofol-DE: neutron exposure between 2x10 9 n/cm 2 and 2x10 10 n/cm 2 and developing time 6 minutes; CR-39: neutron exposure between 3x10 9 n/cm 2 and 2x10 10 n/cm 2 and developing time 25 minutes. The present results were compared with those ones determined to other track detectors, and discussed according to the theory of the image formation in solid state nuclear track detectors based on the optical properties of a single track. (author)

  2. Fragmentation cross section measurements of iron projectiles using CR-39 plastic nuclear track detectors

    CERN Document Server

    Flesch, F; Huentrup, G; Roecher, H; Streibel, T; Winkel, E; Heinrich, W

    1999-01-01

    For long term space missions in which larger radiation doses are accumulated it is necessary to improve the precision of models predicting the space radiation environment. Different models are available to determine the flux of cosmic ray heavy ions behind shielding material. The accuracy of these predictions depends on the knowledge of the fragmentation cross sections, especially at energies of several hundred MeV/nucleon, where the particle flux is at a maximum and especially for those particles with high LET, i.e. iron nuclei. We have measured fragmentation cross sections of sup 5 sup 6 Fe projectiles at beam energies of 700 and 1700 A MeV using experimental set-ups with plastic nuclear track detectors. In this paper we describe the experimental technique to study the fragmentation reactions of sup 5 sup 6 Fe projectiles using CR-39 plastic nuclear track detectors. Results for different targets are presented.

  3. Energy spectrum of iron nuclei measured inside the MIR space craft using CR-39 track detectors

    International Nuclear Information System (INIS)

    Guenther, W.; Leugner, D.; Becker, E.; Flesch, F.; Heinrich, W.; Huentrup, G.; Reitz, G.; Roecher, H.; Streibel, T.

    1999-01-01

    We have exposed stacks of CR-39 plastic nuclear track detectors inside the MIR space craft during the EUROMIR95 space mission for almost 6 months. Over this long period a large number of tracks of high LET events was accumulated in the detector foils. The etching and measuring conditions for this experiment were optimized to detect tracks of stopping iron nuclei. We found 185 stopping iron nuclei inside the stack and identified their trajectories through the material of the experiment. Based on the energy-range relation the energy at the surface of the stack was determined. These particles allow the determination of the low energy part of the spectrum of iron nuclei behind shielding material inside the MIR station

  4. Theoretical calculation on CR-39 response for radon measurements and optimum diffusion chambers dimensions

    Energy Technology Data Exchange (ETDEWEB)

    Askari, H.R.; Ghandi, Kh. [Department of Physics, Faculty of Science, Vali-e-Asr University, Rafsanjan 7713936417 (Iran, Islamic Republic of); Rahimi, M. [Department of Physics, Faculty of Science, Vali-e-Asr University, Rafsanjan 7713936417 (Iran, Islamic Republic of)], E-mail: rahimi_bam@yahoo.com; Negarestani, A. [International Center for Science and High Technology and Environmental Sciences, Kerman (Iran, Islamic Republic of)

    2008-11-11

    One method to measure radon gas concentration in the air with a long time of radiation is trace chemical etching technique. There is a direct proportion between the number of traces on solid-state nuclear track detectors (SSNTDs) and activity concentration of radon. In this paper, calibration constant for a cylindrical chamber with CR-39 detector has been measured analytically. Using this measurement, trace curves on the base of concentration for chambers with different heights and radii have been drawn. The results show that to measure radon gas concentration, the optimum chamber should have a height between 3.5 and 4 cm and a radius between 2.5 and 3.2 cm.

  5. Theoretical calculation on CR-39 response for radon measurements and optimum diffusion chambers dimensions

    International Nuclear Information System (INIS)

    Askari, H.R.; Ghandi, Kh.; Rahimi, M.; Negarestani, A.

    2008-01-01

    One method to measure radon gas concentration in the air with a long time of radiation is trace chemical etching technique. There is a direct proportion between the number of traces on solid-state nuclear track detectors (SSNTDs) and activity concentration of radon. In this paper, calibration constant for a cylindrical chamber with CR-39 detector has been measured analytically. Using this measurement, trace curves on the base of concentration for chambers with different heights and radii have been drawn. The results show that to measure radon gas concentration, the optimum chamber should have a height between 3.5 and 4 cm and a radius between 2.5 and 3.2 cm.

  6. Interrelated temperature dependence of bulk etch rate and track length saturation time in CR-39 detector

    International Nuclear Information System (INIS)

    Azooz, A.A.; Al-Jubbori, M.A.

    2013-01-01

    Highlights: • New empirical parameterization of CR-39 bulk etch rate. • Bulk etch rates measurements using two different methods give consistent results. • Temperature independence of track saturation length. • Two empirical relation between bulk etch rate and temperature are suggested. • Simple inverse relation between bulk etch rate and track saturation time. -- Abstract: Experimental measurements of the etching solution temperature dependence of bulk etch rate using two independent methods revealed a few interesting properties. It is found that while the track saturation length is independent of etching temperature, the etching time needed to reach saturation is strongly temperature-dependent. It is demonstrated that there is systematic simple inverse relation between track saturation time, and etching solution temperature. In addition, and although, the relation between the bulk etch rate and etching solution temperature can be reasonably described by a modified form of the Arrhenius equation, better fits can be obtained by another equation suggested in this work

  7. Nuclear tracks in CR-39 produced by carbon, oxygen, aluminium and titanium ions.

    Science.gov (United States)

    Rickards, J; Romo, V; Golzarri, J I; Espinosa, G

    2002-01-01

    This work describes the response of CR-39 (allyl diglycol polycarbonate) to different ions (C, O, Al and Ti) produced by the Instituto de Fisica 3 MV 9SDH-2 Pelletron accelerator and backscattered from a thin Au film on a C support. The ion energies were chosen in series such that the ranges of the different ions in the detector were 2, 3, 4, 5, 6, 7 and 8 microm respectively for each series. Once exposed, the detectors were etched with a solution of 6.25 M KOH at 60 degrees C, and the reading was carried out using a digital image analysis system. An analysis of the measured track diameters of all the types of ions indicates that, for a given range, track kinetics are independent of type of ion, energy and stopping power.

  8. Determination of the exhalation rate of radon and thoron from building materials by detectors Cr-39

    International Nuclear Information System (INIS)

    Vasidov, A.

    2005-01-01

    Full text: The building materials (BM) such as granite, bricks, sand, cement etc., contain uranium and thorium in various amounts. Therefore the knowledge of true value exhalation rate of Rn and Tn from BM represents scientific and practical interest in environmental radiation protection. In present work, we have used calibrated plastic cups with two detectors Cr-39. The detected surface of the cup is situated in perpendicular position surface BM and were exposed for 20-30 days. The first detector fixed the bottom on distance from surface of BM and records alpha particles from Rn-222 only. The second detector records alpha particles of the thoron and radon. After exposition, the detectors chemically etched and analyzed. The values of the exhalation rate per unit area of the granite, concrete, fired and unfired bricks, sand, cement, alabaster varied 0.091 - 0.1 Bq m -2 h -1 for the radon, 200 - 5800 Bq m -2 h - 1 for the thoron, accordingly

  9. Evolution of etched nuclear track profiles of alpha particles in CR-39 by atomic force microscopy

    International Nuclear Information System (INIS)

    Félix-Bautista, R.; Hernández-Hernández, C.; Zendejas-Leal, B.E.; Fragoso, R.; Golzarri, J.I.; Vázquez-López, C.; Espinosa, G.

    2013-01-01

    A series of atomic force microscopy (AFM) images of etched nuclear tracks has been obtained and used to calculate the nuclear track registration sensitivity parameter V(x) = Vt(x)/Vb. Due to the AFM limitations the samples were irradiated normally to the surface, and with energies attenuated in order to include the Bragg peak region in the AFM piezo-scanner z movement range. The simulation of the track profile evolution was then obtained. The different stages of etched nuclear track profiles were rendered. - Highlights: ► Using AFM we reach that Bragg peak region of etched tracks in CR-39. ► The etched track sensitivity V was calculated by data obtained by AFM. ► The evolucion of etched nuclear tracks was simulated by data achieved by AFM

  10. CR-39 nuclear track detector application for the diagnostics of low energy high power ion beams

    Energy Technology Data Exchange (ETDEWEB)

    Opekounov, M S; Pechenkin, S A; Remnev, G E [Nuclear Physics Institute, Tomsk (Russian Federation); Ivonin, I V [Siberian Physical-Technical Institute, Tomsk (Russian Federation)

    1997-12-31

    The results of investigation of the spectral composition of ion beams generated by the magneto-insulated ion diode of the MUK-M and TEMP accelerators. The energy and mass characteristics of the accelerated ion beam were determined by a Thomson spectrometer with a CR-39 plate detector (MOM - Atomki Nuclear Track Detector, Type MA-ND/p). The accelerated ion energy was from 40 to 240 keV. The ion current density range was from 1 to 10 A/cm{sup 2}. The mass composition contained hydrogen, nitrogen, carbon and aluminum ions. The individual track analysis showed the track form, depth and diameter in dependence on the ion mass and energy. (author). 2 figs., 5 refs.

  11. Change of Cr-39(DOP) track detector response as a result of space exposure

    International Nuclear Information System (INIS)

    Yadav, J.S.; Singh, R.K.

    1990-01-01

    The response functions for CR-39(DOP) plastic track detectors are calculated, using the simplex method for nonlinear least squares fit, from experimental data obtained from accelerator beams as well as space exposure. The average detector sensitivity is reduced by over 30% in the case of space exposure. The average charge shift for the oxygen group is one charge unit, and it increases with particle charge. The effect decreases with restricted energy loss, which is contrary to that observed in the registration temperature effect. We have discussed various environmental parameters which may produce the observed effect. The registration temperature effect may account for the observed effect (within the errors) for the worst case (temperature) analysis. However, a more reasonable estimate suggests that both the registration temperature as well as pressure during exposure contribute to the observed effect. To discriminate between the separate contributions, further experimental data is needed. (author)

  12. Fast neutron spectrometry based on proton detection in CR-39 detector

    Energy Technology Data Exchange (ETDEWEB)

    Dajko, G.; Somogyi, G.

    1986-01-01

    The authors have developed a home-made proton-sensitive CR-39 track detector called MA-ND/p. Using this and the n-p scattering process the performance of a fast neutron spectrometer has been studied by applying two different methods. These are based on track density determinations by using varying radiator thicknesses at constant etching time and by using varying etching times at fixed radiator thickness, respectively. For both methods studied a computer programme is made to calculate the theoretically expected neutron sensitivity as a function of neutron energy. For both methods the neutron sensitivities, expressed in terms of observable etched proton tracks per neutron, are determined experimentally for 3.3 and 14.7 MeV neutron energies. The theoretical and experimental data obtained are compared.

  13. Fast neutron spectrometry based on proton detection in CR-39 detector

    International Nuclear Information System (INIS)

    Dajko, G.; Somogyi, G.

    1986-01-01

    The authors have developed a home-made proton-sensitive CR-39 track detector called MA-ND/p. Using this and the n-p scattering process the performance of a fast neutron spectrometer has been studied by applying two different methods. These are based on track density determinations by using varying radiator thicknesses at constant etching time and by using varying etching times at fixed radiator thickness, respectively. For both methods studied a computer programme is made to calculate the theoretically expected neutron sensitivity as a function of neutron energy. For both methods the neutron sensitivities, expressed in terms of observable etched proton tracks per neutron, are determined experimentally for 3.3 and 14.7 MeV neutron energies. The theoretical and experimental data obtained are compared. (author)

  14. The influence of chemical etching time on efficiency of radon detection using CR-39

    Energy Technology Data Exchange (ETDEWEB)

    Reway, Adriana P.; Kappke, Jaqueline; Narloch, Danielle C., E-mail: adrireway@hotmail.com, E-mail: jaquelinekappke@gmail.com, E-mail: daninarloch@hotmail.com [Universidade Tecnologica Federal do Parana (UTFPR), Curitiba, PR (Brazil). Departamento Academico de Fisica; Del Claro, Flavia; Paschuk, Sergei A., E-mail: flaviadelclaro@gmail.com, E-mail: spaschuk@gmail.com [Universidade Tecnologica Federal do Parana (UTFPR), Curitiba, PR (Brazil). Programa de Pos-Graduaca em Engenharia Eletrica e Informatica Industrial; Correa, Janine N., E-mail: janine_nicolosi@hotmail.com [Universidade Tecnologica Federal do Parana (UTFPR), Curitiba, PR (Brazil). Departamento Academico de Construcao Civil

    2015-07-01

    Natural radiation is the principal source of human exposure to ionizing radiation. Radon is noble radioactive gas that emanates from the soil and rocks entering the atmosphere of dwellings where it could be accumulated. The inhalation of {sup 222}Rn represents a significant health risk. Solid-State Nuclear Track Detectors (SSNTD) represents an efficient method for alpha particle detection and measurements of the activity concentration of {sup 222}Rn. The aim of present work was to study the etching time impact on CR-39 efficiency in radon activity measurements. The investigation was performed using 80 CR-39 detectors, which were exposed to a source of radon. After the exposition, alpha particle tracks development was achieved by chemical etching using 6.25M NaOH solution and ethanol (2%) at 70°C. Etching alpha particle tracks were identified and counted manually using the optical microscope with magnification of 100x and glass overlay mask. The etching time ranged from 7 to 14 hours. The results show that there is an increase in the number of visible tracks with increased etching time. The number of traces obtained for 7 hours and 8 hours of revelation was 1430 +/- 90 and 2090 +/- 160, respectively. However, for etching time of 13 and 14 hours was not observed statistical increase in the number of visible tracks. The number of tracks in this situation was 3630 +/- 180 and 3870 +/- 160 to 13 and 14 hours etching. Thus, for assumed etching parameters, the etching optimal time was observed 14 hours. (author)

  15. Impact of x-ray dose on track formation and data analysis for CR-39-based proton diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Rinderknecht, H. G., E-mail: rinderknecht1@llnl.gov; Rojas-Herrera, J.; Zylstra, A. B.; Frenje, J. A.; Gatu Johnson, M.; Sio, H.; Sinenian, N.; Rosenberg, M. J.; Li, C. K.; Séguin, F. H.; Petrasso, R. D. [Massachusetts Institute of Technology, Cambridge, Massachusetts 02139 (United States); Filkins, T.; Steidle, Jessica A.; Traynor, N.; Freeman, C. [State University of New York at Geneseo, Geneseo, New York 14454 (United States); Steidle, Jeffrey A. [Rochester Institute of Technology, Rochester, New York 14623 (United States)

    2015-12-15

    The nuclear track detector CR-39 is used extensively for charged particle diagnosis, in particular proton spectroscopy, at inertial confinement fusion facilities. These detectors can absorb x-ray doses from the experiments in the order of 1–100 Gy, the effects of which are not accounted for in the previous detector calibrations. X-ray dose absorbed in the CR-39 has previously been shown to affect the track size of alpha particles in the detector, primarily due to a measured reduction in the material bulk etch rate [Rojas-Herrera et al., Rev. Sci. Instrum. 86, 033501 (2015)]. Similar to the previous findings for alpha particles, protons with energies in the range 0.5–9.1 MeV are shown to produce tracks that are systematically smaller as a function of the absorbed x-ray dose in the CR-39. The reduction of track size due to x-ray dose is found to diminish with time between exposure and etching if the CR-39 is stored at ambient temperature, and complete recovery is observed after two weeks. The impact of this effect on the analysis of data from existing CR-39-based proton diagnostics on OMEGA and the National Ignition Facility is evaluated and best practices are proposed for cases in which the effect of x rays is significant.

  16. Proton Radiography with CR-39 by Using the Protons from High Power Femto-second Laser System

    International Nuclear Information System (INIS)

    Choi, Chang Il; Lee, Dong Hoon; Kang, Byoung Hwi; Kim, Yong Kyun; Choi, Il Woo; Ko, Do Kyeong; Lee, Jong Min

    2008-01-01

    Proton radiography techniques are useful to obtain a high quality image of a thin object, because protons travel straight in matter. Generation of the high energy proton using conventional accelerator costs high and requires large accelerating facility. But proton radiography using high power femto-second(10-15 second) laser has been interested, because it can generate high energy protons at lower price than the conventional accelerator like a cyclotron. For this study, we used the CR-39 SSNTD (Solid State Nuclear Track Detector) as the proton radiography screen. Commonly, CR-39 is used to detect the tracks of energetic charged particles. Incident energetic charged particles left latent tracks in the CR-39, in the form of broken molecular chains and free radicals. These latent tracks show high chemical reactivity. After chemical etching with the caustic alkali solution such as NaOH or KOH, tracks are appeared to forms of hole. If protons with various energies enter the two targets with another thickness, number of protons passed through the target per unit area is different each other. Using this feature of protons, we can a proton radiographic image with CR-39. We studied proton radiography with CR-39 by using energetic protons from high power femto-second laser and evaluated potentiality of femto-second laser as new energetic proton generator for radiography

  17. An energy and direction independent fast neutron dosemeter based on electrochemically etched CR-39 nuclear track detectors

    International Nuclear Information System (INIS)

    James, K.; Matiullah; Durrani, S.A.

    1987-01-01

    A computer-based model is presented, which simulates the dose equivalent response of electrochemically etched CR-39 to fast neutrons of various energies and angles of incidence. Most previous calculations of the response of CR-39 have neglected the production of recoiling oxygen and carbon nuclei as well as α particles in the CR-39. We calculate that these 'heavy recoils' and α particles are the major source of electrochemically etchable tracks in bare CR-39 at neutron energies above approx. 2 MeV under typical etching conditions. Our calculations have been extended to predict the response of CR-39 used in conjunction with various combinations of polymeric front radiators and we have determined the radiator stack configuration with produces the most energy independent response. Again, the heavy recoils and α particles cannot be neglected and, for energies above approx. 2 MeV, these produce typically about 20% of the total response of our optimum stack. This type of fast neutron dosemeter is, however, strongly direction dependent. We have integrated the response over all appropriate angles to predict the dose equivalent response for two representative neutron fields, and we suggest a method for minimising the angular dependence. (author)

  18. Impact of x-ray dose on track formation and data analysis for CR-39-based proton diagnostics

    International Nuclear Information System (INIS)

    Rinderknecht, H. G.; Rojas-Herrera, J.; Zylstra, A. B.; Frenje, J. A.; Gatu Johnson, M.; Sio, H.; Sinenian, N.; Rosenberg, M. J.; Li, C. K.; Séguin, F. H.; Petrasso, R. D.; Filkins, T.; Steidle, Jessica A.; Traynor, N.; Freeman, C.; Steidle, Jeffrey A.

    2015-01-01

    The nuclear track detector CR-39 is used extensively for charged particle diagnosis, in particular proton spectroscopy, at inertial confinement fusion facilities. These detectors can absorb x-ray doses from the experiments in the order of 1–100 Gy, the effects of which are not accounted for in the previous detector calibrations. X-ray dose absorbed in the CR-39 has previously been shown to affect the track size of alpha particles in the detector, primarily due to a measured reduction in the material bulk etch rate [Rojas-Herrera et al., Rev. Sci. Instrum. 86, 033501 (2015)]. Similar to the previous findings for alpha particles, protons with energies in the range 0.5–9.1 MeV are shown to produce tracks that are systematically smaller as a function of the absorbed x-ray dose in the CR-39. The reduction of track size due to x-ray dose is found to diminish with time between exposure and etching if the CR-39 is stored at ambient temperature, and complete recovery is observed after two weeks. The impact of this effect on the analysis of data from existing CR-39-based proton diagnostics on OMEGA and the National Ignition Facility is evaluated and best practices are proposed for cases in which the effect of x rays is significant

  19. Effect of various etching conditions on the response of Cr-39 plastic track detector applied for radon dosimetry in environment

    International Nuclear Information System (INIS)

    Maged, A.F.; Ashraf, F.A.

    1997-01-01

    A solid state nuclear track detector Cr-39 has been used for measuring the radon concentration in the soil air and indoor concentration. The bulk etch rate, C B of Cr-39 has been measured in various concentrations of NaOH in the range (6-8 mole) at temperature 70 degree C. In addition, the track etch rate, V T , and the ratio V = V T /V B , of alpha particles emitted from radon gas exists in nature have been measured in a similar range of etching conditions. This study shows that 8 M NaOH at 70 degree C represent the optimum etching conditions for Cr-39, with the range of the present study. The equilibrium factor and gamma-dose equivalent were calculated by using the track densities of open and filtered solid state nuclear track detectors

  20. A quick method for maintaining the molarity of NaOH solution during continuous etching of CR-39

    International Nuclear Information System (INIS)

    Khan, E.U.; Husaini, S.N.; Malik, F.; Sajid, M.; Karim, S.; Qureshi, I.E.

    2002-01-01

    A series of experiments have been performed to investigate the physio-chemical changes that occurred in the 6 M NaOH solution after etching CR-39 (Pershore and Homalite) detectors, each for 3, 6, 9, 12 and 15 h. Various physical parameters like concentration, electrical conductivity (EC) and density of the solutions have been measured after each etching interval. Results have been discussed in the light of stoichiometrical equation for the interaction of CR-39 with NaOH. It is found that the concentration, EC and the density of the solution, in which CR-39 has been etched, increase linearly with respect to the etching time. The inter-relationship of EC-concentration and density-concentration suggest that the concentration of the etchant can be maintained at certain desired value by adjusting the corresponding value of EC or density, measured through non-destructive and quick methods

  1. Effect of certain production parameters and post-production treatments on the etching characteristics of CR-39 sheets

    Energy Technology Data Exchange (ETDEWEB)

    Somogyi, G.; Toth-Szilagyi, M.; Hunyadi, I.; Hafez, A.-F.

    1986-01-01

    There is a permanent need in producing track recording detectors of well defined behaviour from CR-39 monomer. Therefore, more studies on the role of production parameters determining the stability of main etching characteristics (bulk etch rate, Vsub(B);etch rate ratio, Vsub(T)/Vsub(B);opaqueness after longer etching periods) are highly required. In our studies we have examined different commercial CR-39 sheets (Homalite, Pershore, MA-ND) to compare their registration sensitivity to selected alpha and proton energies. In addition, we have investigated the main etching parameters of CR-39 sheets manufactured under different casting conditions varying the concentration of initiator and certain additives. Finally, the effect of some post-production treatments, annealing and storage in vacuum, on the Vsub(B) and Vsub(T)/Vsub(B) values is studied.

  2. A fast neutron spectrometer based on an electrochemically etched CR-39 detector with degrader and front radiator

    International Nuclear Information System (INIS)

    Matiullah; Durrani, S.A.

    1987-01-01

    In addition to having promising applications for the development of a fast-neutron dosemeter, electrochemically etched (ECE) CR-39 detectors also offer the possibility of energy-selective fast-neutron detection. This property stems basically from the fact that, to produce 'sparkable' trails in the polymeric detector subjected to ECE, the charged particle resulting from a neutron interaction must fall within a definite 'energy window'. The lower and upper limits of proton energies that can yield ECE spots in CR-39 have been experimentally determined to be ∼ 50 keV and ∼ 2.2 MeV under our processing conditions. To accomplish our objective, we have developed a technique based on ECE spot-density measurements in CR-39 detectors placed in conjuction with judiciously chosen thicknesses of a polyethylene radiator and a lead degrader. The optimum thicknesses of the radiator and the degrader, for a given neutron energy, are determined by computer calculations. (author)

  3. Uranium concentration in blood samples of Southern Iraqi leukemia patients using CR-39 track detector

    International Nuclear Information System (INIS)

    Al-Hamzawi, A.A.; Al-Qadisiyah University, Qadisiyah; Jaafar, M.S.; Tawfiq, N.F.

    2014-01-01

    The simple and effective technique of fission track etch has been applied to determine trace concentration of uranium in human blood samples taken from two groups of male and female participants: leukemia patients and healthy subjects group. The blood samples of leukemia patients and healthy subjects were collected from three key southern governorates namely, Basrah, Muthanna and Dhi-Qar. These governorates were the centers of intensive military activities during the 1991 and 2003 Gulf wars, and the discarded weapons are still lying around in these regions. CR-39 track detector was used for registration of induced fission tracks. The results show that the highest recorded uranium concentration in the blood samples of leukemia patients was 4.71 ppb (female, 45 years old, from Basrah) and the minimum concentration was 1.91 ppb (male, 3 years old, from Muthanna). For healthy group, the maximum uranium concentration was 2.15 ppb (female, 55 years old, from Basrah) and the minimum concentration was 0.86 ppb (male, 5 years old, from Dhi-Qar). It has been found that the uranium concentrations in human blood samples of leukemia patients are higher than those of the healthy group. These uranium concentrations in the leukemia patients group were significantly different (P < 0.001) from those in the healthy group. (author)

  4. Track Detection Technique Using CR-39 for Determining Depleted Uranium in Biological Specimens

    International Nuclear Information System (INIS)

    Murbat, S.M.

    2013-01-01

    Track detecting technique using CR-39 track detector has been implemented for determining depleted uranium concentration in biological specimens (tissues, bones, and blood) of patients infected with cancer diseases. Results were compared with specimens of patients infected with conventional diseases (noncancerous). Specimens were collected from middle and south of Iraq have been contaminated with depleted uranium in the Gulf war in 1991. Results show that this technique is efficient for determining depleted uranium concentration in biological specimens. It was found that all studies samples determine for patients infected with cancer diseases contain a high concentration of depleted uranium (more than the international standard) comparing with noncancerous diseases. Moreover, it was found that persons infected with Leukemia show more sensitive to uranium concentrations to induce the diseases (66-202 ppb), while (116- 1910 ppb) concentrations were needed for inducing cancer diseases in organs and tissues. Result confirmed the correlation between cancerous diseases and the munitions made of depleted uranium used in the Gulf war in 1991 leads to contaminate the Iraqi environment and causes a high risk against people in Iraq.

  5. Alpha particle spectroscopy for CR-39 detector utilizing matrix of energy equations

    Energy Technology Data Exchange (ETDEWEB)

    Awad, E.M. [Department of General Sciences, Yanbu Industrial College, PO Box 30436, Madinat Yanbu Al-Sinaiya (Saudi Arabia); Physics Department, Faculty of Science, Menofia University, Shebin El-Koom (Egypt)], E-mail: ayawad@yahoo.com; Soliman, A.A. [Department of Mathematics, Faculty of Education (AL-Arish), Suez Canal University, AL-Arish 45111 (Egypt); Department of Mathematics, Teacher' s College (Bisha), King Khalid University, Bisha, PO Box 551 (Saudi Arabia)], E-mail: asoliman_99@yahoo.com; Rammah, Y.S. [Physics Department, Faculty of Science, Menofia University, Shebin El-Koom (Egypt)

    2007-10-01

    A method for determining alpha-particle energy using CR-39 detector by utilizing matrix of energy equation was described. The matrix was composed from two axes; the track minor axis (m) and diameter of etched out track end (d) axis of some selected elliptical tracks. The energy E in (m,d) coordinate was approximated by matrix of energy equations given by: E{sub k}={sigma}{sub i,j=0}{sup 2}a{sub ij}d{sub k}{sup i}m{sub k}{sup j}, which was identified using two different approaches. First, i and j were treated as power exponents for d and m. The adjusting parameters values a{sub ij} were obtained and the energy of a given track was deduced directly from it. Second, i and j were treated as indices of some chosen tracks that were fitted to obtain iso-energy curves that were superimposed on m-d scatter plot as calibration curves. The energy between any two successive iso-energy curves in this case was assumed varied linearly with d for a given m. The energy matrix in both cases was solved numerically. Results of the two approaches were compared.

  6. Feasibility study of extremity dosemeter based on polyallyl-diglycol-carbonate (CR-39) for neutron exposure

    International Nuclear Information System (INIS)

    Chau, Q.; Bruguier, P.

    2007-01-01

    In nuclear facilities, some activities such as reprocessing, recycling and production of bare fuel rods expose the workers to mixed neutron-photon fields. For several workplaces, particularly in glove boxes, some workers expose their hands to mixed fields. The mastery of the photon extremity dosimetry is relatively good, whereas the neutron dosimetry still raises difficulties. In this context, the Inst. for Radiological Protection and Nuclear Safety (IRSN) has proposed a study on a passive neutron extremity dosemeter based on chemically etched CR-39 (PADC: polyallyl-diglycol-carbonate), named PN-3, already used in routine practice for whole body dosimetry. This dosemeter is a chip of plastic sensitive to recoil protons. The chemical etching process amplifies the size of the impact. The reading system for tracks counting is composed of a microscope, a video camera and an image analyser. This system is combined with the dose evaluation algorithm. The performance of the dosemeter PN-3 has been largely studied and proved by several laboratories in terms of passive individual neutron dosemeter which is used in routine production by different companies. This study focuses on the sensitivity of the extremity dosemeter, as well as its performance in the function of the level of the neutron energy. The dosemeter was exposed to monoenergetic neutron fields in laboratory conditions and to mixed fields in glove boxes at workplaces. (authors)

  7. A comparison of the neutron response of CR-39 made by different manufacturers

    International Nuclear Information System (INIS)

    Ipe, N.E.; Liu, J.C.; Buddemeier, B.R.; Miles, C.J.; Yoder, R.C.

    1991-09-01

    CR-39 was obtained from American Acrylics and Plastics, Inc. (A.A), N. E. Technology, Ltd. (N.E), and Tech/Ops Landauer, Inc. (LT). The dosemeters were exposed to radioisotopic neutron sources at SLAC, and moderated 252 Cf at ORNL. The A.A. and N.E. dosemeters were electrochemically etched (pre-etch in 6.5 N KOH at 60 degrees C for 1 hour and 45 minutes, a 5 hour etch at 3000 V and 60 Hz, a 23 minute blow-up step at 2 kHz and a post-etch for 15 minutes). Track densities were determined with the Homann Track Size Image Analyzer. The LT dosemeters were chemically etched in 5.5 N NaOH at 70 degrees C for 15.5 hours. Some A.A., N.E., and LT dosemeters were etched in 6.25 N NaOH at 70 degrees C for 6 hours. A pre-etch step in 60% methanol and 40% NaOH at 70 degrees C for 1 hour was added for some N.E. dosemeters. The results of these studies are reported in this paper. 3 refs., 2 figs., 2 tabs

  8. Triton, deuteron and proton responses of the CR-39 track detector

    Energy Technology Data Exchange (ETDEWEB)

    Yamauchi, Tomoya; Matsumoto, Hiroyoshi; Oda, Keiji [Kobe Univ. of Mercantile Marine (Japan)

    1996-07-01

    In the present study, we assessed the response of the CR-39 detector to proton, deuteron and triton from their etch-pit growth curves obtained by multi-step etching technique and the difference among their track registration properties was discussed. In order to avoid incorrect evaluation due to the missing track effect, particle irradiation was performed at various incident energies. The response function, S(R), etch rate ratio, S, as a function of the residual range, R, was experimentally evaluated for all hydrogen isotopes by this method. In the next, we obtained another form of response functions of S(E), S({beta}) and S(LET{sub 200}), which were presented as functions of the particle energy, E, the particle velocity, {beta}(=v/c), and the linear energy transfer in the case where the cut-off energy is 200 eV, LET{sub 200}, respectively. These information will be useful also in understanding the fundamentals of the latent track formation mechanism in the plastic track detectors. (J.P.N.)

  9. Calibration factor determination for solid nuclear track detectors CR-39 type exposed to Rn-222

    International Nuclear Information System (INIS)

    Cazula, Camila Dias; Campos, Marcia Pires de; Mazzilli, Barbara Paci

    2014-01-01

    In the detection method with solid nuclear track detector, when a heavy particle rests on the detector surface, causes a breakdown in their molecular structure forming a trace. One of the typical applications of these detectors is the measurement of the concentration of Rn -222 in air, a noble radioactive gas, part of the U-238 series, emitting alpha particles and important in epidemiological studies to protect individuals from natural radiation. To determine the concentration of Rn -222 in the air in a room is necessary to know the density of lines (traces / cm 2 ) on the detector surface, the exposure time and the calibration factor. The determination of the calibration factor for CR-39 detectors was taken from the exposure of these to a known concentration of Rn-222. Therefore, the detectors were placed inside a cell of Lucas adapted and subsequently exposed to a concentration of Rn-222 15 kBq / m 3 , by means of the apparatus RN-150 Pylon Electronics Incorporation, which has a source of Ra-226 and releases known concentrations of Rn-222. Six calibration factor determinations were performed, the average value obtained was 0.0534 ±0.0021 (traces / cm 2 per Bq / m 3 day). The results are consistent with literature values for the same type of detector and showed good reproducibility

  10. Application of CR-39 microfilm for rapid discrimination between alpha-particle sources

    Energy Technology Data Exchange (ETDEWEB)

    Dwaikat, Nidal; Al-karmi, Anan M. [Dept. of Physics, King Fahd University of Petroleum and Minerals, Dhahran (Saudi Arabia)

    2017-06-15

    This work presents a new technique for discriminating between alpha particles of different energy levels. In a first study, two groups of alpha particles emitted from radium-226 and americium-241 sources were successfully separated using a CR-39 microfilm of appropriate thickness. This thickness was adjusted by chemical etching before and after irradiation so that lower-energy particles were stopped within the detector, while higher-energy particles were revealed on the back side of the detector. The number of tracks on the front side of the microfilm represented all alpha particles incident on that side from the two sources. However, the number of tracks on the back side of the microfilm represented only the long-range alpha particles of higher energy that arrived at that side. Therefore, by subtracting the number of tracks on the back side from the number of tracks on the front side, one could easily determine the number of tracks for the short-range alpha particles of lower energy that remained embedded in the microfilm. Discrimination of the two energy levels is thus achieved in a simple, fast, and reliable process.

  11. Study on the influence of CR-39 detector size on radon progeny detection in indoor environments

    Energy Technology Data Exchange (ETDEWEB)

    Pereira, L. A.; Hadler, J. C.; Lixandrão F, A. L.; Guedes, S.; Takizawa, R. H. [Instituto de Física Gleb Wataghin, Universidade Estadual de Campinas, UNICAMP, 13083-970 Campinas, SP (Brazil)

    2014-11-11

    It is well known that radon daughters up to {sup 214}Po are the real contaminants to be considered in case of indoor radon contamination. Assemblies consisting of 6 circular bare sheets of CR-39, a nuclear track detector, with radius varying from 0.15 to 1.2 cm were exposed far from any material surface for periods of approximately 6 months in 13 different indoor rooms (7 workplaces and 6 dwellings), where ventilation was moderate or poor. It was observed that track density was as greater as smaller was the detector radius. Track density data were fitted using an equation deduced based on the assumption that the behavior of radon and its progeny in the air was described by Fick's Law, i.e., when the main mechanism of transport of radon progeny in the air is diffusion. As many people spend great part of their time in closed or poorly ventilated environments, the confirmation they present equilibrium between radon and its progeny is an interesting start for dosimetric calculations concerning this contamination.

  12. Fission studies of gold induced by (1665 MeV) π- using a CR-39 detector

    International Nuclear Information System (INIS)

    Muhammad Ikram Shahzad; Yasin, Zafar; Sher, Gul

    2012-01-01

    The fission cross section and fission probability of 197 Au, induced by (1665 MeV) π'-, have been studied using CR-39 track detectors. A 4π-geometry was used to count track statistics. A beam of negative pions of 1665 MeV was produced at AGS of Brookhaven National Laboratory, USA, and allowed to fall normally on the stack. Two detectors from the stack were scanned for fission fragment tracks after etching in 6N NaOH at 70 ℃. The statistics of fission fragment tracks in both detectors were obtained. It was found that there was a marked asymmetry of registered tracks with respect to the forward and backward hemispheres. This asymmetry could be partly accounted for on the basis of momentum transfer to the struck nucleus. On the basis of counting statistics fission cross section was measured, and fission probability was determined by dividing the fission cross section with the reaction cross section. The fission cross-section and fission probability were compared with the computed values using the cascade-exciton model code CEM95. (authors)

  13. Uranium concentration measurements in human blood for some governorates in Iraq using CR-39 track detector

    International Nuclear Information System (INIS)

    Tawfiq, N.F.; Ali, L.T.; Al-Jobouri, H.A.

    2013-01-01

    The sensitive and simple technique of fission track etch has been applied to determine trace concentration of uranium in blood samples for occupational and non-occupational workers, male and female, using CR-39 track detector that is employed for registration of induced fission tracks. The results show that the highest recorded uranium concentration in human blood of workers in the ministry of Science and Technology were 1.90 ppb (male, 36 years old, 12 years' work experience, and living in Basrah governorate) and minimum concentration 0.26 ppb (female, 40 years old, 10 years' work experience, and living in Baghdad), while for non-occupational worker, the maximum uranium concentration was 1.76 ppb (female, 63 years old, and living in Al-Muthana) and minimum concentration was 0.28 ppb (female, 20 years old, and living in Baghdad). It has also been found that the uranium concentration in human blood samples of workers in the ministry of Science and Technology are higher than those of non-occupational workers, and the uranium concentrations for female workers and for non-occupational workers were higher than those for male workers and non-occupational workers. (author)

  14. New approach of modeling charged particles track development in CR-39 detectors

    International Nuclear Information System (INIS)

    Azooz, A.A.; Hermsdorf, D.; Al-Jubbori, M.A.

    2013-01-01

    In this work, previous modeling of protons and alpha particles track length development in CR-39 solid state nuclear track detectors SSNTD is modified and further extended. The extension involved the accommodation of heavier ions into the model. These ions include deuteron, lithium, boron, carbon, nitrogen and oxygen ions. The new modeling does not contain any case sensitive free fitting parameters. Model calculation results are found to be in good agreement with both experimental data and SRIM software range energy dependence predictions. The access to a single unified and differentiable track length development equation results in the ability to obtain direct results for track etching rates. - Highlights: • New modeling of ions track length evolution measured by different authors. • Ions considered are p, d, α, Li, B, C, N, O. • Equations obtained to describe L(t) and etch rate for all ions at wide energy range. • Equations obtained do not involve any free fitting parameters. • Ions range values obtained compare well with results of SRIM software

  15. Studies of biocompatibility of chemically etched CR-39 SSNTDs in view of their applications in alpha-particle radiobiological experiments

    International Nuclear Information System (INIS)

    Li, W.Y.; Chan, K.F.; Tse, A.K.W.; Fong, W.F.; Yu, K.N.

    2006-01-01

    Alpha-particle radiobiological experiments involve irradiating cells with alpha particles and require thin biocompatible materials which can record alpha-particle traversals as substrates for cell cultures. The biocompatibilities of chemically etched CR-39 solid-state nuclear track detectors (SSNTDs) using aqueous NaOH or NaOH/ehtanol are studied through the abundance and morphology of the cultured HeLa cells. The wetting properties of these etched CR-39 SSNTDs are also studied. The moderately hydrophobic CR-39 SSNTDs as well as the hydrophobic NaOH/ethanol-etched CR-39 SSNTDs are more biocompatible than the hydrophilic aqueous-NaOH-etched SSNTDs. Too small water contact angles, too large surface energy (γ s ) or the polar component γ s p do not favor the cell culture. On the other hand, the dispersive component γ s d of the surface energy and the ratio γ s p /γ s d do not seem to significantly affect the biocompatibility

  16. Some characteristics of the CR-39 solid state nuclear - Track Detector for register of protons and low energy alpha particles

    International Nuclear Information System (INIS)

    Fonseca, E.S. da.

    1983-01-01

    Experimental results related to registration properties of the CR-39 Solid State Nuclear Track Detector for charged particles are presented and discussed. The existence of an inverse proportion between the induction time and the temperature as well as normal concentration of solutions, is showed by the study of CR-39 chemical etching characteristics in NaOH and KOH solutions, comprising varied concentration and temperature. The bulk-etch rate and activation energy of the process were obtained. The critical energy and critical energy-loss rate of CR-39 track-detectors for registration of protons were experimentally determined. Samples were exposed to 24 Mev proton beams in the IEN/CNEN Cyclotron (CV-28), using scattering chamber with a tantalum thin target and aluminium absorbers in contact with the samples, in order to provide the required fluctuation in the scattered beam energy. From the mean track-diameter plotted against incident proton energy the critical energy was obtained. From the calculated energy-loss rate vs. energy curve, the critical energy loss rate were evaluated. The CR-39 response for low energy alpha particles (E = 7h) under the conditions of 6.25 N NaOH at 70 0 C. It is shown that successive chemical etchings do not produce the same track geometry as obtained by means of a continous revelation with the same total etching time. (Author) [pt

  17. Neutron measurement in 12,13C+ 27Al system using CR-39 detectors and neutron rem meter

    International Nuclear Information System (INIS)

    Sahoo, G.S.; Tripathy, S.P.; Shanbhag, A.A.; Sunil, C.; Joshi, D.S.; Sarkar, P.K.

    2011-01-01

    In this work, neutron measurements carried out for the interaction of 60 and 67.5 MeV 12 C, 57.3 and 65 MeV 13 C ions with thick aluminium target by using CR-39 detectors and neutron rem meter is reported. Both the detector systems were irradiated at different angles viz. 0 deg, 30 deg, 60 deg, 90 deg with respect to the beam direction. The normalized track density measurements (tracks/cm 2 /projectile at 1m) in CR-39 detectors were correlated with the normalized dose equivalent values (μSv/projectile at 1m) obtained using the neutron rem meter. The track density was found to be more in case of 13 C than 12 C. However in all the cases, the track density per incident projectile was found to decrease as the angle with respect to beam direction increases, indicating non-isotropic nature of neutron emission. The ratio between measured dose equivalent in rem meter to the measured track densities in CR-39 detectors was found to be 2.8±0.2, which remains constant irrespective of the change in angle from beam direction as well as neutron spectrum, indicating a flat dose response of CR-39 detectors. (author)

  18. Calibration of detectors type CR-39 for methodology implementation for Radon-222 determination in CRCN-NE, Brazil

    International Nuclear Information System (INIS)

    Silva, Karolayne E.M. da; Santos, Mariana L. de O.; Amaral, Déric S. do; Vilela, Eldice C.; França, Elvis J. de; Hazin, Clovis A.; Farias, Emerson E.G. de

    2017-01-01

    Radon-222 is a radioactive gas, a product of the decay of uranium-238, which emits alpha particles and represents more than 50% of the dose of natural radiation received by the population. Therefore, monitoring of this gas is essential. For indoor measurement, solid state detectors can be used, the most common of which is CR-39. For monitoring using CR-39, alpha particles, generated by radon-222 and the daughter radionuclides, strike the surface of the detector and generate traces. To relate the trace density per exposure area in environments with unknown activity concentration, it is necessary to determine the calibration factor. The objective of this study was to calibrate CR-39 type detectors for the implementation of the radon determination methodology in Centro Regional de Ciencias Nucleares do Nordeste - CRCN-NE of Brazilian Nuclear Energy Commission - CNEN. In order to determine the CR-39 calibration factor, 19 exposures of the detectors were performed in the CRCN-NE calibration chamber (RN1-CRCN) at an activity of 5.00 kBq m -3 , with the exposure time varying from 24 to 850 hours. For the detection of the detectors, sodium hydroxide was used in a thermostat bath at 90 ° C for 5 hours. The count of number of traits per unit of field was performed with the aid of optical microscopy with an increase of 100 times, being read 30 fields per dosimeters. As a result, the calibration factor was obtained, and the linear response of the trace density as a function of exposure was observed. The results allow the use of CR-39 in the determination of radon-222 by CRCN-NE

  19. Investigation of the Effect of He-Ne Laser on the Optical Properties through Etched CN-85 and CR-39 Containing Alpha Tracks

    International Nuclear Information System (INIS)

    Zaki, M.F.; Hegazy, T.M.; Taha, D.H.

    2013-01-01

    The effects of He-Ne laser on the optical characteristics of Cellulose nitrate, CN-85, and Poly allyl diglycole carbonate, CR-39, nuclear track detectors have been studied by using photoluminescence (PL) and UV-visible spectroscopic techniques. The polymers irradiated with alpha particles with close contact to 241 Am and then exposed to He-Ne laser with different doses. The laser energy intensities ranged between 0 and 217 J/cm 2 . The change in the PL spectra may be explained by chain conformational disorders as well as chain scission. From the UV-visible spectra, it is found that a shift in the absorption edge towards a longer wavelength with increasing laser doses can be readily observed. The absorption peak with increasing dose is seen to change into a broad one. The optical band gaps determined from the UV-visible spectra were found to decrease with the increase of energy intensities of He-Ne laser. These results have been explained on the basis of scission of the polymers due to laser irradiation. The UV absorption tail formation in both polymers was related to the diminution of optical band gap. Results show good correlation with the applied doses.

  20. Study etching characteristics of a track detector CR-39 with ultraviolet laser irradiation

    International Nuclear Information System (INIS)

    Dwaikat, Nidal; Iida, Toshiyuki; Sato, Fuminobu; Kato, Yushi; Ishikawa, Ippei; Kada, Wataru; Kishi, Atsuya; Sakai, Makoto; Ihara, Yohei

    2007-01-01

    The effect of pulsed ultraviolet Indium-doped Yttrium Aluminum Garnet (UV-In:YAG) laser of λ=266 nm, pulse energy 42 mJ/pulse at repetition rate10 Hz on the etching characteristics of Japanese CR-39 was studied at various energy intensities. Fifteen detectors were divided into two sets, each of seven samples and one sample was kept as a reference.The first set (post-exposed) was first exposed to alpha radiation with close contact to 241 Am and then treated in air with laser in the energy intensity range from 40 to160 J/cm 2 , 20 J/cm 2 in step. The second set (pre-exposed) was irradiated in reverse process (laser+alpha) with the same sources as the first set and under the same condition. The laser energy intensities ranged between 20 and 140 J/cm 2 , 20 J/cm 2 in step. For post-exposed samples (alpha+laser) bulk etch rate decreases up to 60 J/cm 2 and increases thereafter, while for pre-exposed samples (laser+alpha) the bulk etch rate oscillates without showing any precise periodicity. The bulk etch rate for both sets was found to be the same at 60≤energy intensity≤80 J/cm 2 and this may indicate that the same structural changes have happened. The track etch rate was found to be equal to the bulk etch rate for both sets, so the sensitivity is constant. In both sets several changes on the detector surfaces: tracks of different sizes and shapes and high density within the laser spot were observed. Out of the laser spot, the tracks become larger and lower density, indicating cross-linking and scission have happened, simultaneously, on the same surface as a result of UV-laser irradiation

  1. Calculation of depleted uranium concentration in dental fillings samples using the nuclear track detector CR-39

    International Nuclear Information System (INIS)

    Mahdi, K. H.; Subhi, A. T.; Tawfiq, N. F.

    2012-12-01

    The purpose of this study is to determine the concentration of depleted uranium in dental fillings samples, which were obtained some hospital and dental office, sale of materials deployed in Iraq. 8 samples were examined from two different fillings and lead-filling (amalgam) and composite filling (plastic). concentrations of depleted uranium were determined in these samples using a nuclear track detector CR-39 through the recording of the tracks left by of fragments of fission resulting from the reaction 2 38U (n, f). The samples are bombarded by neutrons emitted from the neutron source (2 41A m-Be) with flux of ( 10 5 n. cm- 2. s -1 ). The period of etching to show the track of fission fragments is 5 hours using NaOH solution with normalization (6.25N), and temperature (60 o C ). Concentration of depleted uranium were calculated by comparison with standard samples. The result that obtained showed that the value of the weighted average for concentration of uranium in the samples fillings (5.54± 1.05) ppm lead to thr filling (amalgam) and (5.33±0.6) ppm of the filling composite (plastic). The hazard- index, the absorbed dose and the effective dose for these concentration were determined. The obtained results of the effective dose for each of the surface of the bone and skin (as the areas most affected by this compensation industrial) is (0.56 mSv / y) for the batting lead (amalgam) and (0.54 mSv / y) for the filling composite (plastic). From the results of study it was that the highest rate is the effective dose to a specimen amalgam filling (0.68 mSv / y) which is less than the allowable limit for exposure of the general people set the World Health Organization (WHO), a (1 mSv / y). (Author)

  2. Measuring depths of sub-micron tracks in a CR-39 detector from replicas using Atomic Force Microscopy

    International Nuclear Information System (INIS)

    Yu, K.N.; Ng, F.M.F.; Nikezic, D.

    2005-01-01

    One of the challenging tasks in the application of solid-state nuclear track detectors (SSNTDs) is the measurement of the depth of the tracks, in particular, the shallow ones resulting from short etching periods. In the present work, a method is proposed to prepare replicas of tracks from α particles in the CR-39 SSNTDs and to measure their heights using atomic force microscopy (AFM). After irradiation, the detectors were etched in a 6.25N aqueous solution of NaOH maintained at 70 deg. C. The etched detectors were immersed into a beaker of the replicating fluid, which was placed in a water bath under ultrasonic vibration and maintained at room temperature to facilitate the filling of the etched tracks with the replicating fluid. As an example of application, these results have been used to derive a V function for the CR-39 detectors used in the present study (for the specified etching conditions)

  3. Response of CR-39 Detector Against Fast Neutron Using D-Polyethylene and H-Polyethylene Radiator

    International Nuclear Information System (INIS)

    Sofyan, Hasnel

    1996-01-01

    The research on the response of detector CR-39 by using D-Polyethylene and H-Polyethylene radiator has been carried out. The optimum number of nuclear tracks was found with the use of 30 % NaOH at 80 + 0,5oC for 80 minutes of etching time. The comparison of CR-39 detector response caused by D-Polyethylene radiator against H-Polyethylene radiator of irradiation in air, were found to be 1.18 and 0.84 for 241Am-Be neutron source and neutron source from reactor respectively. For phantom irradiation, the results were found to be 1.75 for 241Am-Be neutron source, and 0.77 for neutron source from reactor

  4. Alpha-particle autoradiography in CR-39: a technique for quantitative assessment of alpha-emitters in biological tissue

    International Nuclear Information System (INIS)

    Fews, A.P.; Henshaw, D.L.

    1983-01-01

    The techniques for α-particle autoradiography based on the plastic nuclear track detector CR-39, previously reported, have been developed considerably. The techniques are applied to α-autoradiography of human lung tissue in particular but are applicable to any biological tissue. The most important developments are: (i) Improvements in the manufacture and pre-etching of the plastic. (ii) High resolution α-particle spectroscopy in CR-39 plastic based on the analysis of the structure of the etched track. (iii) Calculation of the effective thickness of tissue sampled by the plastic. (iv) A deconvolution analysis which takes the distributions of track length and dip angle in the plastic and determines the α-particle range spectrum and distribution of tissue activity with height above the plastic surface. (v) The analysis of radon diffusion in tissue to determine the mean radon diffusion distance in tissue and plastic. (author)

  5. Pershore made CR-39(DOP) as a 1.015 GeV/n 197Au-ion detector

    International Nuclear Information System (INIS)

    Bhattacharyya, D.P.; Chakrabarty, S.; Rakshit, R.; Basu, B.; Pal, P.; Biswas, S.

    1993-01-01

    Pershore made CR-39(DOP) stack was exposed at a zenith angle of 30deg by 197 Au-ions of energy 1.015 GeV/n using LBL BEVALAC beam. The top of the irradiated plate of the stack has been etched in 6.25N NaOH solution at 70degC for one hour. About 1202 cone lengths were optically measured. The estimated etch rate ratio of the incident 197 Au projectile beam in CR-39 has been found to be 27±2. The result has been compared with earlier observation. The charge resolution of the detector has been estimated from the average of double cone lengths and has been found to have a value of (0.58±0.03)e for 197 Au-ions. (orig.)

  6. Some characteristics of the CR-39 solid state nuclear-track detector for protons and low energy alpha particles

    International Nuclear Information System (INIS)

    Fonseca, E.S. da.

    1983-01-01

    Experimental results related to certain registration properties of the CR-39 solid state nuclear-track detector for charged particles are presented and discussed. The determination of the CR-39 chemical etching in NaOH and KOH solutions, comprising concentration (2-10N) and temperature effects (50-90 0 C), showed the existence of an inverse proportion between the induction time and the temperature as well as the normal concentration of the solutions. The critical energy and the critical energy-loss rate of CR-39 track detectors for registration of protons were experimentally determined. A number of samples was exposed to 24MeV proton beams in the IEN-CNEN Cyclotron (CV-28), using a scattering chamber with a tantalum thin target and aluminium absorbers in contact with the samples in order to provide the required fluctuation in the scattered beam energy. From the mean track-diameter plotted against incident proton energy for 16h and 24h chemical etching (6.25 NaOH, 70 0 C), and considering 1.5 μm as the minimum observable track-diameter, the values (21.0 + - 1.5) MeV and (22.5 + - 1.5) MeV were deduced, respectively, for the critical energy. From the calculated energy-loss rate versus energy curve, the critical energy-loss rate was evaluated as 24 + - 2 MeV.cm 2 /g. Finally, the CR-39 response for low energy alpha particles (E [pt

  7. Effects of high neutron doses and duration of the chemical etching on the optical properties of CR-39

    International Nuclear Information System (INIS)

    Sahoo, G.S.; Tripathy, S.P.; Paul, S.; Sharma, S.C.; Joshi, D.S.; Gupta, A.K.; Bandyopadhyay, T.

    2015-01-01

    Effects of the duration of chemical etching on the transmittance, absorbance and optical band gap width of the CR-39 (Polyallyl diglycol carbonate) detectors irradiated to high neutron doses (12.7, 22.1, 36.0 and 43.5 Sv) were studied. The neutrons were produced by bombardment of a thick Be target with 12 MeV protons of different fluences. The unirradiated and neutron-irradiated CR-39 detectors were subjected to a stepwise chemical etching at 1 h intervals. After each step, the transmission spectra of the detectors were recorded in the range from 200 to 900 nm, and the absorbances and optical band gap widths were determined. The effect of the etching on the light transmittance of unirradiated detectors was insignificant, whereas it was very significant in the case of the irradiated detectors. The dependence of the optical absorbance on the neutron dose is linear at short etching periods, but exponential at longer ones. The optical band gap narrows with increasing etching time. It is more significant for the irradiated dosimeters than for the unirradiated ones. The rate of the narrowing of the optical band gap with increasing neutron dose increases with increasing duration of the etching. - Highlights: • The variation of optical properties of CR-39 at very high neutron dose is analyzed. Etching process is found to play a crucial role for change in optical properties of neutron-irradiated CR-39. • The optical absorbance varies linearly at lower dose, at very high dose absorbance saturation occurs. The dose at which saturation absorbance is observed shifts towards lower neutron dose with increase in etching time. • The rate of decrease in optical band gap with respect to neutron dose is found to be more at higher etching durations

  8. Usage of an interactive image analysis system for studying various parameters of etched tracks in CR-39 and Makrofol E

    International Nuclear Information System (INIS)

    Abu-Jarad, F.; Islam, M.A.; Que, A.

    1991-01-01

    An Automated Interactive Built Analysis System (IBAS) is being used to analyze the alpha and fission fragment tracks in CR-39 and Makrofol E detectors. It primarily consists of a control computer (IBAS1) and an image processor (IBAS2). The system is used for counting the nuclear tracks, measuring their areas, diameters, statistics and displaying the frequency distribution of their sizes. All information can be printed out or stored on floppy disks. (author)

  9. Measurement of the variable track-etch rate of hydrogen, carbon and oxygen Ions in CR-39

    International Nuclear Information System (INIS)

    Lengar, I.; Skvarc, J.; Ilic, R.

    2003-01-01

    The ratio of the track-etch rate to the bulk-etch rate for hydrogen, carbon and oxygen ions was studied for the CR-39 detector with addition of dioctylphthalate. The response was reconstructed from etch-pit growth curves obtained by the multi-step etching technique. A theoretical analysis of the correctness of the method due to the 'missing track segment' is assessed and utilisation of the results obtained for the calibration of fast neutron dosimetry is discussed. (author)

  10. Calibration of thermal neutron detection compound BN-1 and CR-39 in the exposure room of Triga Reactor in Ljubljana

    International Nuclear Information System (INIS)

    Kristof, E.; Ilic, R.; Skvarc, J.; Dijanosic, R.

    1994-01-01

    Description of determination of thermal neutron fluences in the range from 1.E+02 to 1.E+12 cm -2 for calibration of the neutron sensitive compound consisting of the neutron converter BN-1 and charged particle detector CR-39 is given. The method employs two proportional BF3 detectors supplemented by a Ge(Li) gamma spectometer utilizing gold foils. The results of the measurements are also presented. (author)

  11. Study of projectile fragmentation in the reaction (158 A GeV) Pb + Pb using CR-39

    CERN Document Server

    Qureshi, I E; Javed, M T; Manzoor, S; Sher, G; Aleem, F; Khan, H A

    2005-01-01

    The fragmentation of Pb ions at 158 A GeV energy produced in the interaction with Pb target has been studied using a CR-39 track detector. A stack comprising of 64 detectors was prepared such that a target of 1 cm thickness was sandwiched between the sheets of CR-39. The purpose of this exposure geometry was to calibrate CR-39 with respect to relativistic heavy ions as well as to study the fragmentation of Pb ions at 158 A GeV energy. The exposure was carried out at the SPS beam facility of CERN at normal incidence with a fluence of . Two detectors from the exposed stack have been selected for this study: one before and the other after the target material. After etching, the detectors were scanned using an optical microscope and the etched track lengths and the diameters of the track openings were measured manually. Considering that the lengths of tracks provide the best charge resolution for Z>65, we have measured track lengths for a sufficiently large number of fragments to identify individual charge states...

  12. Impact of x-ray dose on the response of CR-39 to 1–5.5 MeV alphas

    Energy Technology Data Exchange (ETDEWEB)

    Rojas-Herrera, J., E-mail: jimmy06@mit.edu; Rinderknecht, H. G.; Zylstra, A. B.; Gatu Johnson, M.; Orozco, D.; Rosenberg, M. J.; Sio, H.; Seguin, F. H.; Frenje, J. A.; Li, C. K.; Petrasso, R. D. [Plasma Science and Fusion Center, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139 (United States)

    2015-03-15

    The CR-39 nuclear track detector is used in many nuclear diagnostics fielded at inertial confinement fusion (ICF) facilities. Large x-ray fluences generated by ICF experiments may impact the CR-39 response to incident charged particles. To determine the impact of x-ray exposure on the CR-39 response to alpha particles, a thick-target bremsstrahlung x-ray generator was used to expose CR-39 to various doses of 8 keV Cu-K{sub α} and K{sub β} x-rays. The CR-39 detectors were then exposed to 1–5.5 MeV alphas from an Am-241 source. The regions of the CR-39 exposed to x-rays showed a smaller track diameter than those not exposed to x-rays: for example, a dose of 3.0 ± 0.1 Gy causes a decrease of (19 ± 2)% in the track diameter of a 5.5 MeV alpha particle, while a dose of 60.0 ± 1.3 Gy results in a decrease of (45 ± 5)% in the track diameter. The reduced track diameters were found to be predominantly caused by a comparable reduction in the bulk etch rate of the CR-39 with x-ray dose. A residual effect depending on alpha particle energy is characterized using an empirical formula.

  13. Impact of x-ray dose on the response of CR-39 to 1-5.5 MeV alphas

    International Nuclear Information System (INIS)

    Rojas-Herrera, J.; Rinderknecht, H. G.; Zylstra, A. B.; Gatu Johnson, M.; Orozco, D.; Rosenberg, M. J.; Sio, H.; Seguin, F. H.; Frenje, J. A.; Li, C. K.; Petrasso, R. D.

    2015-01-01

    The CR-39 nuclear track detector is used in many nuclear diagnostics fielded at inertial confinement fusion (ICF) facilities. Large x-ray uences generated by ICF experiments may impact the CR-39 response to incident charged particles. To determine the impact of x-ray exposure on the CR-39 response to alpha particles, a thick-target bremsstrahlung x-ray generator was used to expose CR-39 to various doses of 8 keV Cu-K α and K β x-rays. The CR-39 detectors were then exposed to 1-5.5 MeV alphas from an Am-241 source. The regions of the CR-39 exposed to x-rays showed a smaller track diameter than those not exposed to x-rays: for example, a dose of 3.0 ± 0.1 Gy causes a decrease of (19 ± 2)% in the track diameter of a 5.5 MeV alpha particle, while a dose of 60.0 ± 1.3 Gy results in a decrease of (45 ± 5)% in the track diameter. The reduced track diameters were found to be predominantly caused by a comparable reduction in the bulk etch rate of the CR-39 with x-ray dose. A residual effect depending on alpha particle energy is characterized using an empirical formula

  14. Use of Image Pro Plus for counting of {alpha} particles tracks in CR-39; Uso do Image Pro Plus para contagem de tracos de particulas {alpha} em CR-39

    Energy Technology Data Exchange (ETDEWEB)

    Miranda, Marcia Valeria F.E. Sa [Coordenacao dos Programas de Pos-Graduacao de Engenharia (COPPE/UFRJ), Rio de Janeiro, RJ (Brazil). Programa de Engenharia Nuclear; Centro Regional de Ciencias Nucleares (CRCN-NE/CNEN-PE), Recife, PE (Brazil); Crispim, Verginia Reis [Coordenacao dos Programas de Pos-Graduacao de Engenharia (COPPE/UFRJ), Rio de Janeiro, RJ (Brazil). Programa de Engenharia Nuclear; Gomes, Rogerio dos S.; Gomes, Joana D' Arc R. Lopes, E-mail: mvaleria@cnen.gov.b, E-mail: verginia@con.ufrj.b, E-mail: rogeriog@cnen.gov.b, E-mail: jlopes@cnen.gov.b [Comissao Nacional de Energia Nuclear (CNEN), Rio de Janeiro, RJ (Brazil)

    2011-10-26

    This paper measured the radon radiations present in NORM samples, through the diffusion chambers which contained a nuclear track detector (CR-39). For automatic counting of those tracks the computer program Image Pro plus was used. This paper reports the application of Image Pro plus for counting the nuclear tracks, coming from the radon radiation present in NORM samples. As the radiation rate of {sup 222}Rn if proportional to the number of these tracks, the methodology allowed to compare the levels of contamination of the analysed samples. Also, tables and graphics are presented with counting results referring to the stage of validation of Image Pro plus

  15. The etching property of the surface of CR-39 and the track core radius of fission fragment

    CERN Document Server

    Mineyama, D; Yamauchi, T; Oda, K; El-Rahman, A

    2002-01-01

    The etch pits of fission fragments in CR-39 detector have been observed carefully using an atomic force microscope (AFM) after extremely short chemical etching in stirred 6N KOH solution kept at 70degC. It was found that there existed a thin layer where the bulk etch rate is relativity from large the etch-pit growth curve for the etching duration between 10 and 1800 seconds. The track core radius of fission fragment was evaluated to be about 6 nm from the extrapolation of the growth curve in a thinner region. (author)

  16. Measurement of concentrations of radon and its daughters in indoor atmosphere using CR-39 nuclear track detector

    International Nuclear Information System (INIS)

    Khan, A.J.; Sharma, K.C.; Varshney, A.K.; Prasad, Rajendra; Tyagi, R.K.

    1988-01-01

    The concentrations of radon and its daughters in rooms having different environmental conditions are measured using CR-39 nuclear track detector. It has been found that the radon concentration inside the rooms depends on ventilation, sub-soil emanation and the housed materials. The use of internal wall coverings such as plaster, distemper and white washing may reduce the radon emanation inside the rooms. The use of paints on walls is the best for reducing the radon concentration inside the rooms. (author). 11 refs

  17. Background tracks in CR-39 SSNTD sheets: their control and prediction through an interplay of etching parameters

    International Nuclear Information System (INIS)

    Bhagwat, A.M.; Naik, G.R.; Thampan, S.; Rudran, K.; Joshi, V.B.; Iyer, M.R.

    1992-01-01

    High sensitivity of CR-39 film in turn leads to higher and variable background track-densities. A two-step etching process, each consisting of CE and ECE, is therefore suggested which permits not only partial freezing of the background but also allows to know its level. The procedure identifies bad pieces with scratches and determines the minimum detection limit (MDL) of each film individually. Activities as low as 0.2 mBq (∼ 5 x 10 -15 curies) can thus be measured with low background films for exposure periods of 7-10 days (exposure is carried out after first processing). (author)

  18. Application of combined TLD and CR-39 PNTD method for measurement of total dose and dose equivalent on ISS

    International Nuclear Information System (INIS)

    Benton, E.R.; Deme, S.; Apathy, I.

    2006-01-01

    To date, no single passive detector has been found that measures dose equivalent from ionizing radiation exposure in low-Earth orbit. We have developed the I.S.S. Passive Dosimetry System (P.D.S.), utilizing a combination of TLD in the form of the self-contained Pille TLD system and stacks of CR-39 plastic nuclear track detector (P.N.T.D.) oriented in three mutually orthogonal directions, to measure total dose and dose equivalent aboard the International Space Station (I.S.S.). The Pille TLD system, consisting on an on board reader and a large number of Ca 2 SO 4 :Dy TLD cells, is used to measure absorbed dose. The Pille TLD cells are read out and annealed by the I.S.S. crew on orbit, such that dose information for any time period or condition, e.g. for E.V.A. or following a solar particle event, is immediately available. Near-tissue equivalent CR-39 P.N.T.D. provides Let spectrum, dose, and dose equivalent from charged particles of LET ∞ H 2 O ≥ 10 keV/μm, including the secondaries produced in interactions with high-energy neutrons. Dose information from CR-39 P.N.T.D. is used to correct the absorbed dose component ≥ 10 keV/μm measured in TLD to obtain total dose. Dose equivalent from CR-39 P.N.T.D. is combined with the dose component <10 keV/μm measured in TLD to obtain total dose equivalent. Dose rates ranging from 165 to 250 μGy/day and dose equivalent rates ranging from 340 to 450 μSv/day were measured aboard I.S.S. during the Expedition 2 mission in 2001. Results from the P.D.S. are consistent with those from other passive detectors tested as part of the ground-based I.C.C.H.I.B.A.N. intercomparison of space radiation dosimeters. (authors)

  19. Study of α-energy discrimination in CR-39 track etch detectors for use as a radon/thoron dosemeter

    International Nuclear Information System (INIS)

    Kandaiya, S.; Al-Najjar, S.A.R.; Piesch, E.

    1988-01-01

    The properties of CR 39 nuclear track detectors were evaluated for their α-energy discrimination up to 8.77 MeV using a combination of chemical-electrochemical track revealing techniques. Using three field strengths, α-energy discrimination by ECE track diameter and track density as a function of chemical pre-etching time were studied. α-energy spectra using different irradiation geometries were then evaluated using the optimum conditions and then compared with those obtained form other techniques. (author)

  20. Energy-dependent etching-related impacts on CR-39 alpha detection efficiency for the Rn-222 and Rn-220 decay chains

    Science.gov (United States)

    Tan, Y.; Yuan, H.; Kearfott, K. J.

    2018-04-01

    CR-39 detectors are widely used to measure environmental levels of Rn-222, Rn-220 and their progeny. Prior research reported the CR-39 detection efficiency for alpha particles from Rn-222, Rn-220 and their progeny under a variety of etching conditions. This paper provides an explanation for interesting observations included in that work, namely that the critical incidence angle decreases with the increasing particle energy and the detection efficiency for 8.78 MeV alpha particles is zero. This paper explains these phenomena from a consideration of the interaction of alpha particles with the CR-39 detectors and the physics of etching dynamics. The proposed theory provides a rationale for an approach to optimizing the etching conditions of CR-39 detector for measuring Rn-222, Rn-220 and their progenies.

  1. Changes in CR-39 proton sensitivity due to prolonged exposure to high vacuums relevant to the National Ignition Facility and OMEGA.

    Science.gov (United States)

    Manuel, M J-E; Rosenberg, M J; Sinenian, N; Rinderknecht, H; Zylstra, A B; Séguin, F H; Frenje, J; Li, C K; Petrasso, R D

    2011-09-01

    When used at facilities like OMEGA and the NIF, CR-39 is exposed to high vacuum environments before and after irradiation by charged particles and neutrons. Using an electrostatic linear accelerator at MIT, studies have been conducted to investigate the effects of high vacuum exposure on the sensitivity of CR-39 to fusion protons in the ~1-9 MeV energy range. High vacuum conditions, of order 10(-5) Torr, experienced by CR-39 samples at these facilities were emulated. It is shown that vacuum exposure times longer than ~16 h before proton irradiation result in a decrease in proton sensitivity, whereas no effect was observed for up to 67 h of vacuum exposure after proton irradiation. CR-39 sensitivity curves are presented for samples with prolonged exposure to high vacuum before and after proton irradiation. © 2011 American Institute of Physics

  2. Operational trials of single- and multi-element CR-39 dosemeters for the DIDO and PLUTO reactors at the Harwell Laboratory

    International Nuclear Information System (INIS)

    Gallacher, G.G.; Perks, C.A.

    1993-01-01

    Single- and multi-element CR-39 dosemeters, developed at the Harwell Laboratory, and a commercially available multi-element CR-39 dosemeter (obtained from Track Analysis Systems Ltd), were evaluated for their potential as neutron dosemeters for personnel working at Harwell Laboratory's research reactors. Owing to the angular dependence of the CR-39 (processed using electrochemical etching), the single-element dosemeter was found to be impractical. Consequently, a multi-element dosemeter was developed, which consisted of a cube of side 36 mm with CR-39 elements (also processed using electrochemical etching) attached to each of the sides. Although this dosemeter was technically suitable for this type of dosimetry, it was considered to be unacceptably bulky in personnel trials. The commercially available CR-39 dosemeter tested was much smaller (the CR-39 was only chemically etched) and this was considered to be acceptable as a personnel dosemeter. In addition, trials with personnel working at active handling glove boxes indicated that single-element dosemeters might be adequate, but further work would be needed to verify this. (author)

  3. Activation energy of etching for CR-39 as a function of linear energy transfer of the incident particles

    CERN Document Server

    Awad, E M

    1999-01-01

    In this work, we have studied the effect of the radiation damage caused by the incident particles on the activation energy of etching for CR-39 samples. The damage produced by the incident particle is expressed in terms of the linear energy transfer (LET). CR-39 samples from American Acrylic were irradiated to three different LET particles. These are N (LET sub 2 sub 0 sub 0 = 20 KeV/mu m) as a light particle, Fe (LET sub 2 sub 0 sub 0 = 110 KeV/mu m) as a medium particle and fission fragments (ff) from a sup 2 sup 5 sup 2 Cf source as heavy particles. In general the bulk etch rate was calculated using the weight difference method and the track etch rate was determined using the track geometry at various temperatures (50-90 deg. C) and concentrations (4-9 N) of the NaOH etchant. The average activation energy E sub b related to the bulk etch rate v sub b was calculated from 1n v sub b vs. 1/T. The average activation energy E sub t related to the track etch rate v sub t was estimated from 1n v sub t vs. 1/T. It...

  4. Interaction of 84 MeV/u 12C with 208Pb target investigated with CR-39 plastic track detector

    International Nuclear Information System (INIS)

    Grabez, B.

    1984-01-01

    The interaction of the 84 MeV/u 12 C ions with 208 Pb target was investigated using CR-39 plastic track detector. The first part of the work was dedicated to the examination of the methodology of the recently presented CR-39 detector and its calibration. Measurements have been done on tracks of various ions in the broad atomic number region from Z = 2 to Z = 92. The possibility of the identification of low energy fragments produced in nuclear interactions by measurements on the finished tracks was studied. Our results show that very good charge resolution can be achieved through determination of the mean etch rate ratio and the range of low energy ions. In the second part of the work it was shown that the main reaction channels in the interaction of 84 MeV/u C with Pb target are spallation, fission and fragmentation. The contribution of the multifragmentation is less than 1% of the total reaction cross section. From our results follows that the most probable reaction channels after collision with small impact parameter are fragmentation and deep spallation. The spallation and fission come after more peripheral collisions. (orig./HSI)

  5. Calibration of CR-39 plastic detectors in various modes and radon measurement in the north-western region of Bangladesh

    International Nuclear Information System (INIS)

    Islam, G.S.; Islam, M.A.; Haque, A.K.F.

    1998-04-01

    Solid State track detectors have been extensively used for the measurement of time integrated radon levels in dwellings under different conditions. The CR-39 plastic detectors were calibrated for bare as well as cup with membrane mode, along with a mono dispersal aerosol 0.2μm in size in an exposure chamber, to find the relationship between track densities and the radon concentration as well as potential alpha energy concentration (WL) of radon. Measurement of the indoor radon and radon daughter concentrations were performed in houses in the north-western region of Bangladesh. In total 163 detectors were placed for measurement of indoor radon activities and 230 detectors for measurement of radon daughter concentrations. To study the underground radon activity, 114 CR-39 detectors in cylinders were used. The indoor radon activity in Naogaon was, in general, found to be higher than that in Rajshahi. The working levels in the mud-built houses were greater than that in brick-built houses. The underground radon activity of Naogaon was found to be 6 times higher than that of Rajshahi. No direct correlation was observed between the underground and indoor radon activity. The average values of radon activity and the working level for the north-western zone of Bangladesh are found to be 91 Bq. m -3 and 16 mWL respectively. (author)

  6. Tetraethyl ammonium hydroxide (TEAH) as etchant of CR-39 for the determination of fluence of alpha particles

    Energy Technology Data Exchange (ETDEWEB)

    Joshirao, Pranav M.; Vyas, Chirag K.; Eappen, K.P. [Department of Energy Science, Sungkyunkwan University, Suwon 440746 (Korea, Republic of); Shin, Jae Won [Department of Physics, Sungkyunkwan University, Suwon 440746 (Korea, Republic of); Hong, Seung-Woo [Department of Energy Science, Sungkyunkwan University, Suwon 440746 (Korea, Republic of); Department of Physics, Sungkyunkwan University, Suwon 440746 (Korea, Republic of); Manchanda, Vijay K., E-mail: vkm49@skku.edu [Department of Energy Science, Sungkyunkwan University, Suwon 440746 (Korea, Republic of); School of Electronics and Electrical Engineering, Sungkyunkwan University, Suwon 440746 (Korea, Republic of)

    2014-04-01

    Highlights: • Etching time of CR-39 with TEAH–NaOH mixture (at 80 °C) is less than 20 min. • Etched products enhance etching rate. • V{sub B} and V{sub T} values increase exponentially with temperature. • Activation energy of bulk etching and track etching were determined as 0.87 ± 0.02 eV. - Abstract: Choice of chemical etchant and temperature are pivotal to the successful employment of organic/polymeric solid state nuclear track detectors for determining the fluence of charged particles like protons, alpha and other heavy ions. Poly(diethyleneglycol-bis-(allylcarbonate)) (CR-39) is one of the most sensitive detectors for monitoring the alpha particles but suffers from the drawback of long etching period. An attempt has been made in the present work to investigate a mixture, 20% (v/v) tetraethylammonium hydroxide (40%) – 80% NaOH (6 M) (TEAH–NaOH) at varying temperature as an alternate etchant. It was found that bulk/track etch rate increased and as a consequence etching time decreased significantly (about 10 times) when the mixture was used at 80 °C. Mechanistically, improved efficiency of TEAH–NaOH was attributed to its larger organophilicity and lower etching activation energy as compared to NaOH.

  7. Design and development of wide energy neutron REM equivalent spectrometer-dosimeters based on polycarbonates and Cr-39

    International Nuclear Information System (INIS)

    Faermann, S.

    1985-03-01

    This work describes a system composed of a Rem response personnel neutron dosemeter, based on boron radiators and a polycarbonate track detector, for monitoring dose equivalents in the energy range 1 eV to 14 MeV, an electrochemical etching system for revealing damage sites in solid state track etch detectors, a reader for magnifying the etched pits and a microprocessor for evaluating the dose equivalents and their uncertainties. The performance and directional dependence of the dosemeter when exposed to monoenergetic and polyenergetic neutron fields in the epithermal and fast energy regions are discussed. Saturation effects in polycarbonate foils are presented and a comparison is made between the response of polycarbonate and CR-39 foils, used as passive detectors in the dosemeter. A new passive miniature fast neutron spectrometer-dosimeter is also described. The device is based on the detection of proton tracks by electrochemical etching of CR-39 foils covered with thin polyethylene layers of different thicknesses. By means of this device it is possible to assess the fast neutron energy spectrum in 10 energy intervals in the energy range 0.5-15 MeV. Dose equivalents can be determined in the dose equivalent range 20 mRem to 8 Rem, approximately (author)

  8. Measurement of fast neutron spectrum using CR-39 detectors and a new image analysis program (autoTRAKn)

    International Nuclear Information System (INIS)

    Paul, Sabyasachi; Tripathy, S.P.; Sahoo, G.S.; Bandyopadhyay, T.; Sarkar, P.K.

    2013-01-01

    An attempt is made to estimate the neutron spectrum using the CR-39 (Solid state nuclear track) detector and a new image analyzing program. For this purpose the earlier developed program (autoTRAK) is modified by introducing the required features such as angular correction for the recoil particles, fluence-to-dose conversion coefficient, detection sensitivity of CR-39 detectors, etc. to make it applicable for neutron spectrometry and dosimetry. This upgraded program (autoTRAK n ) is tested with a mono-energetic source (D–T) and two other standard neutron sources, viz. 241 Am–Be and 252 Cf. The program is validated by reproducing these standard spectra, and comparing with the spectra reported by other investigators using different measuring techniques. The ratios of dose equivalent (H ⁎ (10)) to fluence (Φ) are also estimated from the spectra and are compared with the reference values for these neutron sources. An additional feature of this program is explored for counting high density overlapping tracks more precisely and effectively compared to other commonly used image analyzing softwares. This method is found to be simple and promising, which can always be used as a supplementary measuring technique. The details of the modified program, reproduction and comparison of the neutron spectra, reproducibility of the methodology and example of overlapping track counting are presented and discussed. -- Highlights: •A novel image analysis technique (autoTRAK n ) is developed to evaluate CR-39 detectors used for neutron spectrometry and dosimetry. •The methodology is tested to reproduce three standard neutron spectra, (a) D–T, (b) 241 Am–Be, and (c) 252 Cf. •A good matching is observed between dosimetric values obtained by the program and the available reference values. •The program autoTRAK n is also observed to be efficient to distinguish high density overlapping tracks without any segregation procedure. •The methodology seems to be simple, which

  9. Change in the sensitivity of CR-39 for alpha-tracks after the storage at different temperatures

    International Nuclear Information System (INIS)

    Enomoto, Hiroko; Ishigure, Nobuhito

    2000-01-01

    The effect of storage on track registration property of CR-39 has been investigated. Pieces of CR-39 plate were irradiated with normally incident α-particles and fission fragments using a 252 Cf source prior and posterior to the storage of them in air for one year at different temperatures of -80degC, -23degC, 4degC, 23degC and 35degC. Periodical etching was performed for the pieces stored at different temperatures using the solution of NaOH with 7 mol+l -1 at 70degC for 4 hours. Bulk etch rate (V b ) was obtained from the etch pit diameter (D f ) of fission tracks using the equation: V b =D f /(2t), where t is etching time (h). The sensitivity for α-tracks (S) was obtained from the ratio of the etch pit diameters between α-tracks (D a ) and fission-tracks using the equation: S={1+(D a /D f ) 2 }/{1-(D a /D f ) 2 }-1. The present results show that both the bulk etch rate and α-track sensitivity are not constant, which tend to decrease with storage times and storage temperatures. At -80degC, -23degC and 4degC the change in the sensitivity was negligible. On the other hand, the storage at 23degC for 1 year decreased the sensitivity down to 74%. The most significant effect was observed on the α-track sensitivity at 35degC, which was reduced to 80% for one month, 61% for three months, 42% for six months and 32% for one year. By the comparison of experiments between fading and ageing it is shown that such storage effect is attributed not to fading of latent tracks but mainly to some changes in the detector itself. When CR-39 is used of radon monitoring or neutron monitoring, the following points should be paid attention to: (1) the detector should be stored in a refrigerator before exposure and until etching after the exposure, (2) the change in the sensitivity between the time of calibration and the time of use should be evaluated and the counting efficiency at the measurement should be corrected and (3) for comparison or for interpretation of experimental results

  10. Determination Of Uranium Concentration In Teeth Female Samples Using Fission Tracks In CR-39 From Different Countries

    International Nuclear Information System (INIS)

    Hummadi, S.S

    2010-01-01

    The present study was under taken to measure the uranium concentration in female teeth samples collected from different nationalities.The determination of uranium concentration in these samples has been done by using CR-39 track detector.The nuclear reaction is used as a source of nuclear fission fragments is (n, f) obtained by the bombardment of U-235 with thermal neutrons with flux (5*10 3 n/cm 2 .s) was used from (Am-Be) neutron source.The obtained results show the concentration is ranging from (0.58±0.7ppm) in Oman and Uae to (0.35±0.03ppm)in Iraqi for male, the uranium concentration was the highest in Oman and Uae for female

  11. New possibility for high-resolution spectroscopy of nuclear particles entering CR-39 at selected dip angles

    Energy Technology Data Exchange (ETDEWEB)

    Somogyi, G.; Hunyadi, I.; Hafez, A.F. (Magyar Tudomanyos Akademia, Debrecen. Atommag Kutato Intezete); Espinosa, G. (Universidad Nacional Autonoma de Mexico, Mexico City. Inst. de Fisica)

    1984-01-01

    In nuclear reaction studies a differentiation of the reaction products according to their type and energy is generally required. At right angle of incidence a particle identification method based on the relation between the track diameter and particle energy can be well applied to plastic track detectors of low registration sensitivity. We have tried to extend this 'track-diameter method' to the high-sensitivity CR-39 sheets by selecting special incident angles for particle detection. The utility of such a measuring procedure, called 'track-size method', is presented for alpha and proton spectroscopy. A theory is developed to calculate at arbitrary angles the main parameters affecting the energy resolving power of the 'track-size method', namely the critical layer thickness (which has to be removed from the detector surface for track-induction) and the depth and minor axis of etch-pits.

  12. Determination of detection efficiency for radon and radon daughters with CR 39 track detector - a Monte Carlo study

    International Nuclear Information System (INIS)

    Nikezic, D.

    1994-01-01

    The detection effciency, ρ, (or a calibration coefficient k) for radon measurements with a solid state nuclear track detector CR 39 was determined by many authors. There is a considerable discrepancy among reported values for ρ. This situation was a challenge to develop a software program to calculation ρ. This software is based on Bethe-Bloch's expression for the stopping power for heavy charged particles in a medium, as wll as on the Monte Carlo Method. Track parameters were calculated by using an iterative procedure as given in G. Somogyi et al., Nucl. Instr. and Meth. 109 (1973) 211. Results for an open detector and for the detector in a diffusion chamber were presented in this article. (orig.)

  13. Optimization of microwave-induced chemical etching for rapid development of neutron-induced recoil tracks in CR-39 detectors

    International Nuclear Information System (INIS)

    Sahoo, G.S.; Tripathy, S.P.; Bandyopadhyay, T.

    2014-01-01

    A systematic investigation is carried out to optimize the recently established microwave-induced chemical etching (MICE) parameters for rapid development of neutron-induced recoil tracks in CR-39 detectors. Several combinations of all available microwave powers with different etching durations were analysed to determine the most suitable etching condition. The etching duration was found to reduce with increasing microwave power and the tracks were observed at about 18, 15, 12, and 6 min for 300, 450, 600 and 900 W of microwave powers respectively compared to a few hours in chemical etching (CE) method. However, for complete development of tracks the etching duration of 30, 40, 50 and 60 min were found to be suitable for the microwave powers of 900, 600, 450 and 300 W, respectively. Temperature profiles of the etchant for all the available microwave powers at different etching durations were generated to regulate the etching process in a controlled manner. The bulk etch rates at different microwave powers were determined by 2 methods, viz., gravimetric and removed thickness methods. A logarithmic expression was used to fit the variation of bulk etch rate with microwave power. Neutron detection efficiencies were obtained for all the cases and the results on track parameters obtained with MICE technique were compared with those obtained from another detector processed with chemical etching. - Highlights: • Microwave-induced chemical etching method is optimized for rapid development of recoil tracks due to neutrons in CR-39 detector. • Several combinations of microwave powers and etching durations are investigated to standardize the suitable etching condition. • Bulk-etch rates are determined for all microwave powers by two different methods, viz. gravimetric and removed thickness method. • The method is found to be simple, effective and much faster compared to conventional chemical etching

  14. Assessment of radiation shielding materials for protection of space crews using CR-39 plastic nuclear track detector

    International Nuclear Information System (INIS)

    DeWitt, J.M.; Benton, E.R.; Uchihori, Y.; Yasuda, N.; Benton, E.V.; Frank, A.L.

    2009-01-01

    A significant obstacle to long duration human space exploration such as the establishment of a permanent base on the surface of the Moon or a human mission to Mars is the risk posed by prolonged exposure to space radiation. In order to keep mission costs at acceptable levels while simultaneously minimizing the risk from radiation to space crew health and safety, a judicious use of optimized shielding materials will be required. We have undertaken a comprehensive study using CR-39 plastic nuclear track detector (PNTD) to characterize the radiation shielding properties of a range of materials-both common baseline materials such as Al and polyethylene, and novel multifunctional materials such as carbon composites-at heavy ion accelerators. The study consists of analyzing CR-39 PNTD exposed in front of and behind shielding targets of varying composition and at a number of depths (target thicknesses) relevant to the development and testing of materials for space radiation shielding. Most targets consist of 10 cm x 10 cm slabs of solid materials ranging in thickness from 1 to >30 g/cm 2 . Exposures have been made to beams of C, O, Ne, Si, Ar, and Fe at energies ranging from 290 MeV/amu to 1 GeV/amu at the National Institute of Radiological Sciences HIMAC and the NASA Space Radiation Laboratory (NSRL) at Brookhaven National Laboratory. Analysis of the exposed detectors yields LET spectrum, dose, and dose equivalent as functions of target depth and composition, and incident heavy ion charge, energy, and fluence. Efforts are currently underway to properly weigh and combine these results into a single quantitative estimate of a material's ability to shield space crews from the interplanetary galactic cosmic ray flux.

  15. The use of CH3OH additive to NaOH for etching alpha particle tracks in a CR-39 plastic nuclear track detector

    International Nuclear Information System (INIS)

    Ashry, A.H.; Abdalla, A.M.; Rammah, Y.S.; Eisa, M.; Ashraf, O.

    2014-01-01

    Fast detection of alpha particles in CR-39 detectors was investigated using a new chemical etchant. 252 Cf and 241 Am sources were used for irradiating samples of CR-39 SSNTDs with fission fragments and alpha particles in air at normal temperature and pressure. A series of experimental chemical etching are carried out using new etching solution (8 ml of 10N NaOH+1 ml CH 3 OH) at 60 °C to detect alpha particle in short time in CR-39 detectors. Suitable analyzing software has been used to analyze experimental data. From fission and alpha track diameters, the value of bulk etching rate is equal to 2.73 μm/h. Both the sensitivity and etching efficiency were found to vary with the amount of methanol in the etching solution. Pure NaOH was used as a control to compare with the result from etching in NaOH with different concentrations of CH 3 OH. The etching efficiency is determined and compared with conventional aqueous solution of 6.25N NaOH at 70 °C for etching time equals 5 h. In this study, the obtained etching efficiency shows a considerable agreement with the previous work. - Highlights: • The value of bulk etching rate is equal to 2.73 μm/h. • Fast detection of alpha particles in CR-39 detectors. • Samples of CR-39 have been irradiated with fission fragments. • Etching efficiency was determined

  16. Environmental dosimetry of radon-222 and daughters: measurement of absolute calibration factors of CR-39 considering the plate-out effects and environmental factors

    International Nuclear Information System (INIS)

    Paulo, S.R. de.

    1991-08-01

    The subject of this work concerns with the measurement of absolute calibration factors for the use of CR-39 as an absolute detector in indoor and daughters monitoring. Up to now the usefulness of calibration factors was restricted to environmental conditions equal (or very close) to those worthing during their determinations. This fact is consequence of the difficulties related to the understanding of the plate-out properties of radon daughters activity in the air. The plate-out effects on radon daughters monitoring performed by SSNTDs are studied. Our experimental results are in agreement with those of other authors about the great sensitivity of CR-39 to the plate-out effects, fact that recommended its use in this work. Being succeeded in the employment of CR-39 as an alpha-spectrometer we concluded that some important information (like the radon daughters deposition rates on the walls of an environment) can be achieved. The knowledge about the behavior of plate-out made possible the determination of the ranges in zenithal angle and energy where CR-39 can detect alpha-particles with efficiency of 100%, at our conditions of track observation. In this way, we obtained calibration factors for CR-39 that are weakly dependent on environmental conditions. We think that these results can contribute to the improvement of RD (Radiation Detector) detection techniques. (author). 159 refs, 106 figs, 05 tabs

  17. A novel method to recover DD fusion proton CR-39 data corrupted by fast ablator ions at OMEGA and the National Ignition Facility

    Energy Technology Data Exchange (ETDEWEB)

    Sutcliffe, G. D., E-mail: gdsut@mit.edu; Milanese, L. M.; Orozco, D.; Lahmann, B.; Gatu Johnson, M.; Séguin, F. H.; Sio, H.; Frenje, J. A.; Li, C. K.; Petrasso, R. D. [Plasma Science and Fusion Center, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139 (United States); Park, H.-S.; Rygg, J. R.; Casey, D. T.; Bionta, R.; Turnbull, D. P.; Huntington, C. M.; Ross, J. S. [Lawrence Livermore National Laboratory, Livermore, California 94550 (United States); Zylstra, A. B. [Los Alamos National Laboratory, Los Alamos, New Mexico 87545 (United States); Rosenberg, M. J.; Glebov, V. Yu. [Laboratory for Laser Energetics, Rochester, New York 14623 (United States)

    2016-11-15

    CR-39 detectors are used routinely in inertial confinement fusion (ICF) experiments as a part of nuclear diagnostics. CR-39 is filtered to stop fast ablator ions which have been accelerated from an ICF implosion due to electric fields caused by laser-plasma interactions. In some experiments, the filtering is insufficient to block these ions and the fusion-product signal tracks are lost in the large background of accelerated ion tracks. A technique for recovering signal in these scenarios has been developed, tested, and implemented successfully. The technique involves removing material from the surface of the CR-39 to a depth beyond the endpoint of the ablator ion tracks. The technique preserves signal magnitude (yield) as well as structure in radiograph images. The technique is effective when signal particle range is at least 10 μm deeper than the necessary bulk material removal.

  18. A novel method to recover DD fusion proton CR-39 data corrupted by fast ablator ions at OMEGA and the National Ignition Facility

    Energy Technology Data Exchange (ETDEWEB)

    Sutcliffe, G. D. [Plasma Science and Fusion Center, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, USA; Milanese, L. M. [Plasma Science and Fusion Center, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, USA; Orozco, D. [Plasma Science and Fusion Center, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, USA; Lahmann, B. [Plasma Science and Fusion Center, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, USA; Gatu Johnson, M. [Plasma Science and Fusion Center, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, USA; Séguin, F. H. [Plasma Science and Fusion Center, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, USA; Sio, H. [Plasma Science and Fusion Center, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, USA; Frenje, J. A. [Plasma Science and Fusion Center, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, USA; Li, C. K. [Plasma Science and Fusion Center, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, USA; Petrasso, R. D. [Plasma Science and Fusion Center, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, USA; Park, H. -S. [Lawrence Livermore National Laboratory, Livermore, California 94550, USA; Rygg, J. R. [Lawrence Livermore National Laboratory, Livermore, California 94550, USA; Casey, D. T. [Lawrence Livermore National Laboratory, Livermore, California 94550, USA; Bionta, R. [Lawrence Livermore National Laboratory, Livermore, California 94550, USA; Turnbull, D. P. [Lawrence Livermore National Laboratory, Livermore, California 94550, USA; Huntington, C. M. [Lawrence Livermore National Laboratory, Livermore, California 94550, USA; Ross, J. S. [Lawrence Livermore National Laboratory, Livermore, California 94550, USA; Zylstra, A. B. [Los Alamos National Laboratory, Los Alamos, New Mexico 87545, USA; Rosenberg, M. J. [Laboratory for Laser Energetics, Rochester, New York 14623, USA; Glebov, V. Yu. [Laboratory for Laser Energetics, Rochester, New York 14623, USA

    2016-08-05

    CR-39 detectors are used routinely in inertial confinement fusion (ICF) experiments as a part of nuclear diagnostics. CR-39 is filtered to stop fast ablator ions which have been accelerated from an ICF implosion due to electric fields caused by laser-plasma interactions. In some experiments, the filtering is insufficient to block these ions and the fusion-product signal tracks are lost in the large background of accelerated ion tracks. A technique for recovering signal in these scenarios has been developed, tested, and implemented successfully. The technique involves removing material from the surface of the CR-39 to a depth beyond the endpoint of the ablator ion tracks. The technique preserves signal magnitude (yield) as well as structure in radiograph images. The technique is effective when signal particle range is at least 10 μm deeper than the necessary bulk material removal.

  19. A novel method to recover DD fusion proton CR-39 data corrupted by fast ablator ions at OMEGA and the National Ignition Facility

    International Nuclear Information System (INIS)

    Sutcliffe, G. D.; Milanese, L. M.; Orozco, D.; Lahmann, B.; Gatu Johnson, M.; Séguin, F. H.; Sio, H.; Frenje, J. A.; Li, C. K.; Petrasso, R. D.; Park, H.-S.; Rygg, J. R.; Casey, D. T.; Bionta, R.; Turnbull, D. P.; Huntington, C. M.; Ross, J. S.; Zylstra, A. B.; Rosenberg, M. J.; Glebov, V. Yu.

    2016-01-01

    CR-39 detectors are used routinely in inertial confinement fusion (ICF) experiments as a part of nuclear diagnostics. CR-39 is filtered to stop fast ablator ions which have been accelerated from an ICF implosion due to electric fields caused by laser-plasma interactions. In some experiments, the filtering is insufficient to block these ions and the fusion-product signal tracks are lost in the large background of accelerated ion tracks. A technique for recovering signal in these scenarios has been developed, tested, and implemented successfully. The technique involves removing material from the surface of the CR-39 to a depth beyond the endpoint of the ablator ion tracks. The technique preserves signal magnitude (yield) as well as structure in radiograph images. The technique is effective when signal particle range is at least 10 μm deeper than the necessary bulk material removal.

  20. Charge resolution of a Hungarian brand CR-39(MA-ND) detector exposed to a 84Kr beam of energy 0.45A GeV

    International Nuclear Information System (INIS)

    Bhattacharyya, D.P.; Basu, B.; Pal, P.; Mukherjee, S.C.; Ganguly, A.K.; Hunyady, I.

    1990-01-01

    The Hungarian brand CR-39(MA-ND) plastic has been irradiated with a 84 Kr ion beam of energy 0.45A GeV and etched for four different etching times, viz. 4, 6, 8 and 12 h. The estimated charge resolution of a CR-39(MA-ND) detector for registering the nuclei 32 ≤ Z ≤ 36 was found to be 0.18e which is close to our previous observation of the response with a CR-39(DOP) Pershore made plate exposed to a 1.88A GeV 56 Fe beam at the Lawrence Berkeley Laboratory's Bevalac. It was found that the estimated etch rate ratio V T /V G is independent of etching time. The cone length and minor axis of the etch pits has been found to increase with etching time. (orig.)

  1. Response of CR39 detector to 5 A GeV Si14+ ions and measurement of total charge changing cross-section

    International Nuclear Information System (INIS)

    Gupta, Renu; Kumar, Ashavani

    2013-01-01

    In the present work, response of CR39 track etch detector was obtained by cone-height measurement technique. CR39 track etch detector was used to identify the incident charged particles and their fragments by the measurements of cone-height of tracks using an optical microscope DM6000 M and automated image analyzer system installed with Leica QWin Plus software. The CR39 detector was calibrated and the response points were fitted with a linear relation and all the points are within the limits of the experimental errors. The charge resolution of the detector was calculated to be 0.2e. The response function is obtained and fitted with a linear relation which is good throughout Z/β=6.1–14.1. The experimental value of the total charge changing cross-section of 5 A GeV Si 14+ ion beam in polyethylene and CR39 combined target is σ tot =(734±128) mb. The total charge changing cross-section is compared with the experimental results of others based on cone base-area measurement technique and also fitted by the Bradt–Peters geometrical cross-section. - Highlights: • Charge resolution of 0.2e was obtained by cone-height measurement. • Consistency in manual measurements of cone-heights is presented. • Response of CR39 detector was obtained and fitted with first degree polynomial. • Total charge changing cross-section of 5 A GeV Si 14+ ions in CH 2 and CR39 as a combined target was calculated

  2. Study of the pore-opening process of latent tracks of light low-energetic ions in CR-39 by means of electrolytic etching

    International Nuclear Information System (INIS)

    Oganesyan, V.R.

    2005-01-01

    In this thesis the irradiation of 10-μm thick CR-39 foils with 5.5-7 MeV protons and of 22-400 μm thick CR-39 foils with 4.85-28 MeV α-particles with subsequent determination of the etching velocities is described. By means of scanning electron microscopy (SEM) the pore shape after irradiation was determined. From the analysis of the track profiles by means of SEM the track-nucleus diameter for 28 MeV α particles was determined to 1.4 nm. (HSI)

  3. Computer program for the sensitivity calculation of a CR-39 detector in a diffusion chamber for radon measurements

    Energy Technology Data Exchange (ETDEWEB)

    Nikezic, D., E-mail: nikezic@kg.ac.rs; Stajic, J. M. [Faculty of Science, University of Kragujevac, R. Domanovica 12, Kragujevac 34000 (Serbia); Yu, K. N. [Department of Physics and Materials Science, City University of Hong Kong, 83 Tat Chee Avenue (Hong Kong)

    2014-02-15

    Computer software for calculation of the sensitivity of a CR-39 detector closed in a diffusion chamber to radon is described in this work. The software consists of two programs, both written in the standard Fortran 90 programming language. The physical background and a numerical example are given. Presented software is intended for numerous researches in radon measurement community. Previously published computer programs TRACK-TEST.F90 and TRACK-VISION.F90 [D. Nikezic and K. N. Yu, Comput. Phys. Commun. 174, 160 (2006); D. Nikezic and K. N. Yu, Comput. Phys. Commun. 178, 591 (2008)] are used here as subroutines to calculate the track parameters and to determine whether the track is visible or not, based on the incident angle, impact energy, etching conditions, gray level, and visibility criterion. The results obtained by the software, using five different V functions, were compared with the experimental data found in the literature. Application of two functions in this software reproduced experimental data very well, while other three gave lower sensitivity than experiment.

  4. Study of Indoor Radon /Thoron And Its Hazard Inside Kindergartens In Iraqi Kurdistan Using CR39 Nuclear Track Detectors

    International Nuclear Information System (INIS)

    Ismail, A.H.

    2007-01-01

    Indoor radon /thoron levels with potential alpha energy concentration PAEC), effective dose (H E ) and equilibrium factor (F) were measured using closed and open-can technique, containing CR-39 nuclear track detector. Measurements were carried during summer season inside different Kindergartens in three main regions (Erbil, Duhok and Sullimaniye) in Iraqi Kurdistan. We found that the radon and thoron densities range from (11 to 33 track.cm -2 .d -1 ) for radon and (8 to 29 track.cm -2 .d -1 ) for thoron, with the average radon concentration (96.81 26.939Bq/m 3 ) While an average (PAEC) and (H E ) was (7.68±2.298 mWL) , (2.306± 0.689 mSv/Y) respectively. On the other hands the average equilibrium factor was (0.291±0.01). Consequently, we believe that our results were done when we comparing them with the action levels were recommended by (lCRP 66). The results obtained indicate that various locations have different values of radon/thoron concentration. The differences can be ascribed to variations in grades of uranium at different locations and to some environmental factors such as ventilation, particle concentration, and the deposition of the progeny on surfaces or on the atmospheric aerosol

  5. The effects of pre-etching time on the characteristic responses of electrochemically etched CR-39 neutron dosimeters

    International Nuclear Information System (INIS)

    Sohrabi, M.; Khoshnoodi, M.

    1986-01-01

    The effects of pre-etching time (PET) or duration of etching of fast-neutron-induced-recoil tracks in CR-39 in 6N KOH at 60 0 C on electrochemical etching neutron characteristic responses; i.e. sensitivity and mean recoil track diameter (MRTD) versus KOH normality up to 18N are investigated in this paper. Six sets of responses for PETs of 0, 1, 2, 3, 4, and 5 hours were obtained by using our new multi-chamber ECE (MCECE) system which reduced total operation time to about 6% of the time usually required when single-chamber ECE systems are used. The sensitivity response for zero PET showed a broad plateau and a high sensitivity low-LET peak around 16N. By increasing PET, another peak was also developed around 5N leading to 'double-humped' responses with two maximums around 5N and 16N, and a minimum around 11N. On the other hand, the MRTD responses for all PETs studied showed the same general trend with maximums around 11N. In this paper, shape of tracks under different conditions are also investigated, new optimum conditions such as KOH concentrations of 5, 11, and 15N at 25 0 C, with or without pre-etching, are recommended for tracks of lower-LET recoils including possibly protons, and alpha particle tracks over a broad energy range, and the efficiency of the MCECE system is also demonstrated. (author)

  6. Factors affecting the response of the bubble detector BD-100 and a comparison of its response to CR-39

    International Nuclear Information System (INIS)

    Ipe, N.E.; Busick, D.D.; Pollock, R.W.

    1987-08-01

    The BD-100 is a bubble detector available commercially from Chalk River Nuclear Laboratories, Canada for neutron dosimetry. According to the manufacturer, the BD-100 detects neutrons over an energy range of 100 keV to 14 MeV and the dose equivalent response is independent of energy. The sensitivity of the detector is dependent upon its temperature at the time of irradiation. The sensitized detector self-nucleates upon sharp impact and when heated to temperatures of 48 0 C or greater. The BD-100 is insensitive to low energy gamma rays but responds to 6 MeV photons. The sensitivity (bubbles/μSv) of the BD-100 was found to be energy dependent when exposed to standard neutron sources with average energies ranging from 0.5 to 4.5 MeV. The bubbles formed upon irradiation continued to grow in size with time. The response of electrochemically etched CR-39 to the same neutron sources is also reported for comparison

  7. Study of /sup 210/Pb and /sup 210/Po distributions in environmental samples by CR-39 track detector

    Energy Technology Data Exchange (ETDEWEB)

    Hunyadi, I.; Somogyi, G.; Szilagyi, S. (Magyar Tudomanyos Akademia, Debrecen. Atommag Kutato Intezete)

    1984-01-01

    Activity concentration distributions of long-lived alpha-emitters in aerosol samples are analysed by high-resolution autoradiography in CR-39. A study of the alpha-activity attached to aerosols of different particulate sizes separated by a cascade impactor is also performed. It is found that, in the majority of samples, the alpha-activity can be dominantly related to the presence of /sup 210/Po produced by its beta-active precursor /sup 210/Pb. In our studies we have applied the following methods: 1) analysis of alpha-decay properties by means of autoradiographs taken at different post-sampling times, 2) spectroscopical study of individual alpha-tracks and track clusters by a method developed by us for high-resolution alpha-energy determination. In the second method the parameters to be measured are the major axis of surface track opening, the diameter of etched out track end, the total length measurable on the surface along the projected track, and the thickness of layer etched away from the detector surface.

  8. Distance distribution of bystander effects in alpha-particle irradiated cell populations using a CR-39-based culture dish

    International Nuclear Information System (INIS)

    Gaillard, S.; Pusset, D.; Toledo, S.M. de; Azzam, E.I.; Fromm, M.

    2008-01-01

    Propagation of induced biological effects from irradiated to non-irradiated cells is known to occur in cell cultures exposed to low fluences of charged particles. These bystander effects are currently investigated using microbeam or non-microbeam (broad beams) irradiation techniques. Identification of the targeted and non-targeted bystander cells is critical to our understanding of mechanisms underlying such effects. We developed a novel cell culture dish where the base consists of a thin CR-39 sheet grafted on a thin polyethylene terephthalate (PET) foil. The validity of this device in identifying not only irradiated cells, but also the cellular compartment traversed by the particle track is described. We have optimized track etch parameters that do not interfere with measurement of induced biological endpoints under normal incident irradiation. Thus the culture dishes can be used to determine distance distributions for the propagation of induced biological effects from a hit cell to bystander cells. We describe the computer code developed to determine the distance distributions of propagated biological stress responses in normal human fibroblast cells exposed to very low fluences of alpha particles

  9. Empirical assessment of the detection efficiency of CR-39 at high proton fluence and a compact, proton detector for high-fluence applications

    Energy Technology Data Exchange (ETDEWEB)

    Rosenberg, M. J., E-mail: mrosenbe@mit.edu; Séguin, F. H.; Waugh, C. J.; Rinderknecht, H. G.; Orozco, D.; Frenje, J. A.; Johnson, M. Gatu; Sio, H.; Zylstra, A. B.; Sinenian, N.; Li, C. K.; Petrasso, R. D. [Plasma Science and Fusion Center, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139 (United States); Glebov, V. Yu.; Stoeckl, C.; Hohenberger, M.; Sangster, T. C. [Laboratory for Laser Energetics, University of Rochester, Rochester, New York 14623 (United States); LePape, S.; Mackinnon, A. J.; Bionta, R. M.; Landen, O. L. [Lawrence Livermore National Laboratory, Livermore, California 94550 (United States); and others

    2014-04-15

    CR-39 solid-state nuclear track detectors are widely used in physics and in many inertial confinement fusion (ICF) experiments, and under ideal conditions these detectors have 100% detection efficiency for ∼0.5–8 MeV protons. When the fluence of incident particles becomes too high, overlap of particle tracks leads to under-counting at typical processing conditions (5 h etch in 6N NaOH at 80 °C). Short etch times required to avoid overlap can cause under-counting as well, as tracks are not fully developed. Experiments have determined the minimum etch times for 100% detection of 1.7–4.3-MeV protons and established that for 2.4-MeV protons, relevant for detection of DD protons, the maximum fluence that can be detected using normal processing techniques is ≲3 × 10{sup 6} cm{sup −2}. A CR-39-based proton detector has been developed to mitigate issues related to high particle fluences on ICF facilities. Using a pinhole and scattering foil several mm in front of the CR-39, proton fluences at the CR-39 are reduced by more than a factor of ∼50, increasing the operating yield upper limit by a comparable amount.

  10. Studying the response of CR-39 to radon in non-polar liquids above water by Monte Carlo simulation and measurement

    International Nuclear Information System (INIS)

    Rezaie, Mohammad Reza; Sohrabi, Mehdi; Negarestani, Ali

    2013-01-01

    The application of CR-39 has been extensive for measurement of radon and progeny in air of dwellings, but limited as regards to measurements of radon in water. In this paper, a new method is introduced for efficient measurement of radon in water by registering alpha particle tracks in a CR-39 detector placed in a non-polar medium such as cyclohexane, hexane and olive oil when each mixed with water, then separated and fixed above water, as a two-phase media. The method introduced here is however different from the widely used liquid - liquid extraction technique by liquid scintillation spectrometry since it is a passive detection method (CR-39) in a non-polar liquid with enhanced absorption of radon in the liquid, it has a capability for long sample counting to decrease the minimum detection limit (MDL), it does not require sophisticated low light counting systems, and it has the potential for simultaneous measurements of large number of samples for large-scale applications. It also has a low cost and is readily available. A new Monte Carlo calculation of energy-distance travelled by alphas from radon and progeny in a medium was also investigated. The sensitivity of CR-39 detector to radon and progeny in water was determined under two conditions; in a single-phase and two-phase media. In a single-phase medium, CR-39 is directly placed either in air, water, cyclohexane, hexane or olive oil. When CR-39 is placed directly in water, its sensitivity is (2.4 ± 0.1) × 10 −4 (track/cm 2 )/(Bq.d/m 3 ). In the two-phase media, CR-39 is placed either in cyclohexane, hexane or olive oil when each is fixed above water. The sensitivities in the two-phase media are significantly enhanced and are respectively (1.98 ± 0.10) × 10 −2 , (2.8 ± 0.15) × 10 −2 and (2.86 ± 0.15) × 10 −2 (track/cm 2 )/(Bq.d/m 3 ). The sensitivies are about 76, 82 and 110 times more than that of when CR-39 is directly placed in water. The new method is a novel alternative for radon

  11. Measurement of concentrations of radon and its daughters in indoor atmosphere using CR-39 nuclear track detector

    International Nuclear Information System (INIS)

    Farid, S.M.

    1993-01-01

    This paper presents the results of the measurements of indoor 222 Rn and daughter levels in houses of different types located in different parts of Bangladesh. The passive time-integrated method of using a solid state nuclear track detector (CR-39) was employed for measuring both the 222 Rn gas concentration as well as the potential alpha energy exposure (PAEE) level from the short lived daughters of 222 Rn. The 222 Rn concentration from cup exposure and the PAEE from the bare exposure were obtained directly from the track density using calibration curves. A total of 275 exposures were made in the bare mode in 15 locations and 71 exposures in the cup mode in 6 locations. The geometric mean PAEE level obtained is 9.5 mWL with a geometric standard deviation of 1.9. The corresponding value for 222 Rn concentration are 61.3 Bq.M -3 and 2.4. The total data was collected over a period of one and a half year. The monthly variation of the geometric mean of PAEE is also shown. The annual effective dose equivalent has been estimated for each location by using the conversion factor of 9 mWv per WLM as obtained from ICRP-50. The average PAEE level obtained from the total data is below the intervention level as suggested by US EPA. However, the individual averages for each location show that in 8 out of 15 locations intervention may be considered and in others not intervention is called for. The 222 Rn concentrations at the seven locations are equal or less than the equilibrium equivalent 222 Rn concentration value as suggested by EPA. Attempts have also been made to see the variation in the PAEE levels according to different type of construction material used for the houses. (Author)

  12. Environmental dosimetry of radon-222 and daughters: measurement of absolute calibration factors of CR-39 considering the plate-out effects and environmental factors; Dosimetria ambiental de Rn-222 e filhos: medida da eficiencia absoluta do CR-39 levando-se em conta os efeitos do plate-out e fatores ambientais

    Energy Technology Data Exchange (ETDEWEB)

    Paulo, S.R. de

    1991-08-01

    The subject of this work concerns with the measurement of absolute calibration factors for the use of CR-39 as an absolute detector in indoor and daughters monitoring. Up to now the usefulness of calibration factors was restricted to environmental conditions equal (or very close) to those worthing during their determinations. This fact is consequence of the difficulties related to the understanding of the plate-out properties of radon daughters activity in the air. The plate-out effects on radon daughters monitoring performed by SSNTDs are studied. Our experimental results are in agreement with those of other authors about the great sensitivity of CR-39 to the plate-out effects, fact that recommended its use in this work. Being succeeded in the employment of CR-39 as an alpha-spectrometer we concluded that some important information (like the radon daughters deposition rates on the walls of an environment) can be achieved. The knowledge about the behavior of plate-out made possible the determination of the ranges in zenithal angle and energy where CR-39 can detect alpha-particles with efficiency of 100%, at our conditions of track observation. In this way, we obtained calibration factors for CR-39 that are weakly dependent on environmental conditions. We think that these results can contribute to the improvement of RD (Radiation Detector) detection techniques. (author). 159 refs, 106 figs, 05 tabs.

  13. The effect of ArF laser irradiation (193 nm) on the photodegradation and etching properties of alpha-irradiated CR-39 detectors

    Energy Technology Data Exchange (ETDEWEB)

    Shakeri Jooybari, B. [Department of Energy Engineering and Physics, Amirkabir University of Technology, P.O. Box 15875-4413, Tehran, Islamic Republic of Iran (Iran, Islamic Republic of); Nuclear Science and Technology Research Institute (NSRT), Tehran, Islamic Republic of Iran (Iran, Islamic Republic of); Ghergherehchi, M. [College of Information and Technology/ school of Electronic and Electrical Engineering, Sungkyunkwan University, Suwon (Korea, Republic of); Afarideh, H., E-mail: hafarideh@aut.ac.ir [Department of Energy Engineering and Physics, Amirkabir University of Technology, P.O. Box 15875-4413, Tehran, Islamic Republic of Iran (Iran, Islamic Republic of); Lamehi-Rachti, M. [Nuclear Science and Technology Research Institute (NSRT), Tehran, Islamic Republic of Iran (Iran, Islamic Republic of)

    2015-01-01

    The effects of ArF laser irradiation (λ=193nm) at various fluences (energy dose or energy density) on the etching properties of pre-exposed (laser + alpha) CR-39 detectors were studied. First, UV–Vis and Fourier transform infrared (FTIR) spectra were acquired for non-laser-irradiated and laser-irradiated samples to detect the influence of the ArF laser on the chemical modification of the CR-39. Changes observed in the spectra indicated that the predominant process that occurred upon ArF laser irradiation was a bond-scission process. Thereafter, the mean track and bulk etching parameters were experimentally measured in ArF-laser-irradiated CR-39 detectors exposed to an alpha source ({sup 241}Am, E = 5.49 MeV). Inhomogeneous regions in the laser-irradiated side of the CR-39 demonstrated a variable etching rate on only the front side of the CR-39 detector. New equations are also presented for the average bulk etching rate for these inhomogeneous regions (front side). The mean bulk and track etching rates and the mean track dimensions increased in a fluence range of 0–37.03 mJ/cm{sup 2} because of photodegradation and the scission of chemical bonds, which are the predominant processes in this range. When the fluence was increased from 37.03 to 123.45 mJ/cm{sup 2}, the bulk and track etching rates and the track dimensions slowly decreased because of the formation of cross-linked structures on the CR-39 surface. The behavior of the bulk and track etching rates and the track dimensions appears to be proportional to the dose absorbed on the detector surface. It was observed that as the etching time was increased, the bulk and track etching rates and the track dimensions of the laser-irradiated samples decreased because of the shallow penetration depth of the 193 nm laser and the reduction in the oxygen penetration depth.

  14. Evidence of formation of trans-Fe nuclei in Fe+Al interactions at 1.88 GeV using Cr-39 (DOP) detector

    International Nuclear Information System (INIS)

    Ganguly, A.K.; Chaudhuri, Biva

    1991-01-01

    A wedge-shaped aluminium target was irradiated with 1.88 A GeV Fe beam to study various features of Fe+Al nucleus-nucleus interaction and their dependence on target thickness. The detector employed was a stack of CR-39 (DOP) and Lexan plastic nuclear track detectors which have a characteristically high charge resolution property. To distinguish the actual events from background and buildup a selection criteria for easy and unambiguous rejection of unwanted interfering events the stack of detectors was placed at an angle of 60deg with respect to the beam. After irradiation the CR-39 (DOP) detectors were etched and the elliptic etch-pit diameters were scanned. The diameter distribution of the elliptic etch-pits exhibits the existence of trans Fe nuclei. The production of trans Fe fraction is seen to increase with the thickness of the aluminium target. The possible causes of this increase are being investigated. (author). 12 refs., 4 figs

  15. Response of LR-115 type II and CR-39 plastic track detectors to Am-Be and 14.1-MeV neutrons

    International Nuclear Information System (INIS)

    Bradley, D.A.; Chong, C.S.; Saat, Ahmat; Sidik, A.G.; Ghose, A.M.

    1987-01-01

    The fast-neutron response of the plastic LR-115 type II and CR-39 track detectors have been compared, using a 14.1-MeV neutron generator and a radionuclide Am-Be neutron source (effective primary neutron energy 4.5-MeV). The distribution of track diameters for a range of etching times has been evaluated, taking into account track registration efficiency and the relevant fast neutron scattering cross-sections. The efficiency of etched-track formation in LR-115 type II due to neutron irradiation is approximately double that in CR-39. The 14.1-MeV neutrons also tend to produce tracks in both materials with somewhat greater efficiency than do the lower energy neutrons from the radionuclide source, for a given etching time. (author)

  16. Characterization of plastic nuclear track detectors on solid state, CR-39 and LR-115 and its possibilities application on thermal and fast neutron dosimetry

    International Nuclear Information System (INIS)

    Vallejo Delgado, L.R.

    1989-01-01

    This work is an study about the use feasibility of plastic nuclear track detectors, LR 115, II-B (of Eastmann Kodak Co) and CR-39 (of American Acrylics and Plastics), for thermal and fast neutron dosimetry, respectively. The LR-115 with converter (n, alpha) was exposed to thermal neutrons with energy of 0,046 e V, proceeding from nuclear reactor RECH-1 of Nuclear Energy Chilean Commission. The irradiated films were submited to a chemical etching with NaOH, plus a washing and brushing. The CR-39 with polyethylene irradiator, was exposed to fast neutrons proceeding of calibrated sources of Am-Se. The irradiated plates were submited to a chemical pre-etching with KOH and a electrochemical post-etching. (author)

  17. Measurement of track opening contours of oblique incident 4He and 7Li-ions in CR-39: Relevance for calculation of track formation parameters

    International Nuclear Information System (INIS)

    Hermsdorf, D.; Reichelt, U.

    2010-01-01

    Solid State Nuclear Track Detectors (SSNTD) irradiated in realistic radiation fields exhibits after chemical etching very complex track images resulting from different species of particles and their energy spectra and randomly distributed angles of incidence or emission. Reading out such an etched detector surface with a light microscope, quite different track opening contours are observed. Beside the number of tracks, typically their major and minor axes are measured. In this work following problems arising from such experimental situations will be investigated: ·the measurement of track contour parameters for oblique incident 4 He and 7 Li-ions of different energies and angles in CR-39 detectors ·the theoretical description of the angular variation of both axes. ·the possibility to extract physical and spectroscopic information from major and minor track axes. This analysis is based on an intensive experimental program and the comprehensive study of theoretical models available for description of track revealing processes in CR-39.

  18. A study on measurement of neutrons generated in radiation therapy – Measurement of neurons in CR-39 detection method

    International Nuclear Information System (INIS)

    Park, Cheol-Soo; Cho, Jae-Hwan; Lee, Hae-Kag; Lee, Sun-Yeob; Jang, Hyon-Chol; Dong, Kyung-Rae; Chung, Woon-Kwan; Jin, Lee; Moon, Deog-Hwan; Lee, Kwang-Sung; Yang, Nam-Oh; Cho, Moo-Seong

    2013-01-01

    Highlights: ► To measure the neutrons generated in a linear accelerator. ► Both fast neutrons and thermal neutrons produced an increase in the dose of neutrons generated with increasing irradiation dose. ► The generation of neutrons increased when a wedge filter was used. ► When the SRS cone that required a high dose was used, more neutrons were detected. -- Abstract: The CR-39 [diethylene glycol bis-(allylcarbonate)] neuron detection method was used to measure the dose of neutrons generated in X-ray (photon) therapy conducted in a linear accelerator, and to use high-energy photons as part of the clinical applications to examine the problems associated with the dose for patients caused by the generation of neutrons from high-energy photons used for cancer therapy. According to the experimental results, 0.35 mSv, 0.65 mSv 1.82 mSv of fast neutrons on average were generated from 1 Gy, 2 Gy and 5 Gy of photon irradiation, respectively, whereas 0.26 mSv, 0.56 mSv and 1.23 mSv of thermal neutrons were generated. Both fast neutrons and thermal neutrons produced an increase in the dose of neutrons generated with increasing irradiation dose. With in regard to the dose generated within and around the irradiation area of the photon rays, it was confirmed that more neutrons were generated within the irradiation area. A wedge filer was used to measure the generation of neutrons. According to the measurement results, the generation of neutrons increased when a wedge filter was used. When the SRS cone that required a high dose was used, more neutrons were detected than those in the previous experiment. When fast neutrons were used, 2.85 mSv neutrons on average were generated from 5 Gy of photon irradiation. When thermal neutrons were used, 1.37 mSv neutrons on average were generated from 5 Gy of photon irradiation. Overall, approximately 1.6 times and 1.12 times more fast and thermal neutrons, respectively, were generated than in the case of a general treatment with 5 Gy

  19. Auto-counting of high density overlapping tracks and neutron spectrum measurement using CR-39 detectors and in-house image analysis program

    International Nuclear Information System (INIS)

    Paul, Sabyasachi; Tripathy, S.P.; Sahoo, G.S.; Joshi, D.S.; Bandyopadhyay, T.

    2014-01-01

    An effort is made in this work to overcome the difficulty of counting highly dense and overlapping tracks in solid polymeric track detectors (SPTD) such as CR-39. A program is developed to automatically count the track density which is found to be faster and more precise compared to other commonly used image analysing software. The results obtained by the present methodology are compared with those obtained using other software. (author)

  20. Measurement of target fragments produced by 160 MeV proton beam in aluminum and polyethylene with CR-39 plastic nuclear track detectors

    Czech Academy of Sciences Publication Activity Database

    Ambrožová, Iva; Yasuda, N.; Kodaira, S.; Sihver, L.

    2014-01-01

    Roč. 64, MAY (2014), s. 29-34 ISSN 1350-4487 R&D Projects: GA AV ČR KJB100480901; GA AV ČR IAA100480902; GA MŠk LG14004 Institutional support: RVO:61389005 Keywords : target fragments * high-energy protons * Aluminium * Polyethylene * plastic nuclear track detectors * CR-39 Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders Impact factor: 1.213, year: 2014

  1. Interaction of low-intensity nuclear radiation dose with the human blood: Using the new technique of CR-39NTDs for an in vitro study

    International Nuclear Information System (INIS)

    Ismail, Asaad H.; Jaafar, Mohamad S.

    2011-01-01

    Complete blood counts were analyzed for 30 samples of human blood with radiation dose rate ranging between 10 and 41 μSv/h using a Radium-226 source with different time of exposure. A new technique involving a nuclear track detector type CR-39(CR-39 NTDs) was used to estimate the alpha particle density incident on the blood samples. The results show that the ranges of alpha particle in blood samples and on the surface of CR-39NTDs vary exponentially with energy of alpha particles. This depends on the restricted energy loss and target density. Changes in the blood components due to irradiation occurred for different durations of irradiation, and the duration of irradiation that influenced the blood samples in this study was 6 min. The change in red blood cell (RBC) was negligible, so it is less affected than other blood components. In addition, most changes in the blood contents began at a low radiation dose (10.38-13.41 μSv/h). For the doses 13.41-21.77 μSv/h, platelet (PLT) counts increased rapidly and adversely with the RBC and white blood cell (WBC) due to chromosomal aberration. Besides, rapid PLT count reduction rapidly at high dose (42.1 μSv h) causes thrombocytopenia; in contrast, WBC increased, which is an indication of cancer caused due to increase in alpha particle dose. Generally, our results are in agreement with the essentials of blood content and the principles of biological radiation interaction.

  2. Calibration of detectors type CR-39 for methodology implementation for Radon-222 determination in CRCN-NE, Brazil; Calibração de detectores do tipo CR-39 para implementação da metodologia de determinação de radônio-222 no CRCN-NE

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Karolayne E.M. da; Santos, Mariana L. de O.; Amaral, Déric S. do; Vilela, Eldice C.; França, Elvis J. de; Hazin, Clovis A.; Farias, Emerson E.G. de, E-mail: keesthefany@gmail.com, E-mail: marianasantos_ufpe@hotmail.com, E-mail: dericsoares@gmail.com, E-mail: ecvilela@cnen.gov.br, E-mail: ejfrana@cnen.gov.br, E-mail: chazin@cnen.gov.br, E-mail: emersonemiliamo@yahoo.com.br [Centro Regional de Ciências Nucleares do Nordeste (CRCN-NE/CNEN-PE), Recife, PE (Brazil)

    2017-07-01

    Radon-222 is a radioactive gas, a product of the decay of uranium-238, which emits alpha particles and represents more than 50% of the dose of natural radiation received by the population. Therefore, monitoring of this gas is essential. For indoor measurement, solid state detectors can be used, the most common of which is CR-39. For monitoring using CR-39, alpha particles, generated by radon-222 and the daughter radionuclides, strike the surface of the detector and generate traces. To relate the trace density per exposure area in environments with unknown activity concentration, it is necessary to determine the calibration factor. The objective of this study was to calibrate CR-39 type detectors for the implementation of the radon determination methodology in Centro Regional de Ciencias Nucleares do Nordeste - CRCN-NE of Brazilian Nuclear Energy Commission - CNEN. In order to determine the CR-39 calibration factor, 19 exposures of the detectors were performed in the CRCN-NE calibration chamber (RN1-CRCN) at an activity of 5.00 kBq m{sup -3}, with the exposure time varying from 24 to 850 hours. For the detection of the detectors, sodium hydroxide was used in a thermostat bath at 90 ° C for 5 hours. The count of number of traits per unit of field was performed with the aid of optical microscopy with an increase of 100 times, being read 30 fields per dosimeters. As a result, the calibration factor was obtained, and the linear response of the trace density as a function of exposure was observed. The results allow the use of CR-39 in the determination of radon-222 by CRCN-NE.

  3. A performance test of a new high-surface-quality and high-sensitivity CR-39 plastic nuclear track detector – TechnoTrak

    Energy Technology Data Exchange (ETDEWEB)

    Kodaira, S., E-mail: kodaira.satoshi@qst.go.jp [Radiation Measurement Research Team, National Institute of Radiological Sciences, National Institutes for Quantum and Radiological Science and Technology, Chiba (Japan); Morishige, K. [Research Institute for Science and Engineering, Waseda University, Tokyo (Japan); Kawashima, H.; Kitamura, H.; Kurano, M. [Radiation Measurement Research Team, National Institute of Radiological Sciences, National Institutes for Quantum and Radiological Science and Technology, Chiba (Japan); Hasebe, N. [Research Institute for Science and Engineering, Waseda University, Tokyo (Japan); Koguchi, Y.; Shinozaki, W. [Oarai Research Center, Chiyoda Technol Corporation, Ibaraki (Japan); Ogura, K. [College of Industrial Technology, Nihon University, Chiba (Japan)

    2016-09-15

    We have studied the performance of a newly-commercialized CR-39 plastic nuclear track detector (PNTD), “TechnoTrak”, in energetic heavy ion measurements. The advantages of TechnoTrak are derived from its use of a purified CR-39 monomer to improve surface quality combined with an antioxidant to improve sensitivity to low-linear-energy-transfer (LET) particles. We irradiated these detectors with various heavy ions (from protons to krypton) with various energies (30–500 MeV/u) at the heavy ion accelerator facilities in the National Institute of Radiological Sciences (NIRS). The surface roughness after chemical etching was improved to be 59% of that of the conventional high-sensitivity CR-39 detector (HARZLAS/TD-1). The detectable dynamic range of LET was found to be 3.5–600 keV/μm. The LET and charge resolutions for three ions tested ranged from 5.1% to 1.5% and 0.14 to 0.22 c.u. (charge unit), respectively, in the LET range of 17–230 keV/μm, which represents an improvement over conventional products (HARZLAS/TD-1 and BARYOTRAK). A correction factor for the angular dependence was determined for correcting the LET spectrum in an isotropic radiation field. We have demonstrated the potential of TechnoTrak, with its two key features of high surface quality and high sensitivity to low-LET particles, to improve automatic analysis protocols in radiation dosimetry and various other radiological applications.

  4. Practical consequences for the use of a personal dosimeter for fast neutrons based on CR39 exposed up to one year

    International Nuclear Information System (INIS)

    Boschung, Markus; Fiechtner, Annette; Mayer, Sabine; Wernli, Christian

    2008-01-01

    Full text: At the Paul Scherrer Institut a personal neutron dosimetry system based on chemically etched CR-39 detectors and automatic track counting is in routine use since 1998. In its original design, the dosimeter is sensitive to thermal neutrons and to neutrons in the energy range from 200 keV up to several MeV. The standard exposition period is 3 months. Recently, a novel concept for individual monitoring was implemented at CERN. In this concept, each worker who possibly enters a radiation zone is equipped with a combined dosimeter for the measurement of personal photon and neutron doses. The dosimeter for photon dose measurement has an instant readout capability and dose measurements are done monthly. The dosimeter for neutron measurement is based on CR-39 detectors and is sensitive to fast neutrons only. The CR-39 detector is only evaluated and a neutron dose determined if the monthly personal photon dose exceeds 2 mSv or if the exposition period of the neutron dosimeter exceeds one year. This novel regime of use of the neutron dosimeter has had some important consequences for its practical implementation. A priori, the wearing period of a neutron dosimeter is not known and can range from 1 month up to 12 or even more months. A good knowledge of the long-term behaviour and characteristics of the detector material is needed. But also organisational and administrative issues have to be considered. The paper will outline the adopted procedure covering not only technical but also organisational aspects. The long-term behaviour of background track density and response to 241 Am-Be over one year are described as well as calibrations performed with 241 Am-Be and 252 Cf sources and in the High-Energy Reference Field Facility at CERN (CERF). The concept of individual monitoring at CERN could be transferred to other locations with high energy accelerators such as PSI and DESY. The experience gained with the neutron dosimeter based on CR-39 since introduction of the

  5. Dose-rate effects on the bulk etch-rate of CR-39 track detector exposed to low-LET radiations

    CERN Document Server

    Yamauchi, T; Oda, K; Ikeda, T; Honda, Y; Tagawa, S

    1999-01-01

    The effect of gamma-rays and pulsed electrons has been investigated on the bulk etch rate of CR-39 detector at doses up to 100 kGy under various dose-rate between 0.0044 and 35.0 Gy/s. The bulk etch rate increased exponentially with the dose at every examined dose-rates. It was reveled to be strongly depend on the dose-rate: the bulk etch rate was decreased with increasing dose-rate at the same total dose. A primitive model was proposed to explain the dose-rate effect in which oxygen dissolved was assumed to dominate the damage formation process.

  6. Preliminary results of fission induced by (1068 MeV) pi in Cu, Sn, Au and Bi using CR-39 detectors

    CERN Document Server

    Khan, H A; Shahzad, M I; Manzoor, S; Farooq, M A; Sher, G; Khan, E U; Peterson, R J

    1999-01-01

    Fission probabilities in pion induced reactions exhibit characteristic variations with respect to pion energies and target fissility values. At incident energies well above the pion-nucleon resonances, the statistical model seems to give good description of the observed data. We have used negative pions of energy 1068 MeV, in order to study fission induced in four target materials with fissility values [(Z-1)2/A] ranging from 12 to 32. All targets were arranged in a single stack in such a way that each target coated on a CR-39 detector was sandwiched by another uncoated CR-39 detector plate. The stack was irradiated at the AGS of Brookhaven National Laboratory (USA). This set-up ensures solid angle coverage of almost 4 pi degrees, so that for each fission event one of the fission fragments is expected to be trapped by the forward detector and one by the detector covering backward hemisphere. The effect of pion momentum transfer to the struck nucleus was observed in the form of asymmetry between events counted...

  7. A method for in situ absolute DD yield calibration of neutron time-of-flight detectors on OMEGA using CR-39-based proton detectors

    Energy Technology Data Exchange (ETDEWEB)

    Waugh, C. J., E-mail: cjwaugh@mit.edu; Zylstra, A. B.; Frenje, J. A.; Séguin, F. H.; Petrasso, R. D. [Plasma Science and Fusion Center, MIT, Cambridge, Massachusetts 02139 (United States); Rosenberg, M. J.; Glebov, V. Yu.; Sangster, T. C.; Stoeckl, C. [Laboratory for Laser Energetics, Rochester, New York 14623 (United States)

    2015-05-15

    Neutron time of flight (nTOF) detectors are used routinely to measure the absolute DD neutron yield at OMEGA. To check the DD yield calibration of these detectors, originally calibrated using indium activation systems, which in turn were cross-calibrated to NOVA nTOF detectors in the early 1990s, a direct in situ calibration method using CR-39 range filter proton detectors has been successfully developed. By measuring DD neutron and proton yields from a series of exploding pusher implosions at OMEGA, a yield calibration coefficient of 1.09 ± 0.02 (relative to the previous coefficient) was determined for the 3m nTOF detector. In addition, comparison of these and other shots indicates that significant reduction in charged particle flux anisotropies is achieved when bang time occurs significantly (on the order of 500 ps) after the trailing edge of the laser pulse. This is an important observation as the main source of the yield calibration error is due to particle anisotropies caused by field effects. The results indicate that the CR-39-nTOF in situ calibration method can serve as a valuable technique for calibrating and reducing the uncertainty in the DD absolute yield calibration of nTOF detector systems on OMEGA, the National Ignition Facility, and laser megajoule.

  8. Study of gamma irradiation effects on the etching and optical properties of CR-39 solid state nuclear track detector and its application to uranium assay in soil samples

    International Nuclear Information System (INIS)

    Amol Mhatre; Kalsi, P.C.

    2011-01-01

    The gamma irradiation effects in the dose range of 2.5-43.0 Mrad on the etching and optical characteristics of CR-39 solid state nuclear track detector (SSNTD) have been studied by using etching and UV-Visible spectroscopic techniques. From the measured bulk etch rates at different temperatures, the activation energies for bulk etching at different doses have also been determined. It is seen that the bulk etch rates increase and the activation energies for bulk etching decrease with the increase in gamma dose. The optical band gaps of the unirradiated and the gamma -irradiated detectors determined from the UV-Visible spectra were found to decrease with the increase in gamma dose. These results have been explained on the basis of scission of the detector due to gamma irradiation. The present studies can be used for the estimation of gamma dose in the range of 2.5-43.0 Mrad and can also be used for estimating track registration efficiency in the presence of gamma dose. The CR-39 detector has also been applied for the assay of uranium in some soil samples of Jammu city. (author)

  9. Track detection on the cells exposed to high Linear Energy Transfer heavy-ions by Cr-39 plastic and terminal deoxynucleotidyl transferase(Td T)

    International Nuclear Information System (INIS)

    Mehnati, P.; Keshtkar, A.; Mesbahi, A.; Sasaki, H.

    2006-01-01

    The fatal effect of ionizing radiation on cells depends on Linear Energy Transfer level. The distribution of ionizing radiation is sparse and homogeneous for low Linear Energy Transfer radiations such as X or y, but it is dense and concentrated for high Linear Energy Transfer radiation such as heavy-ions radiation. Materials and Methods: Chinese hamster ovary cells (CHO-K1) were exposed to 4 Gy Fe-ion 2000 keV/μm. The Cr-39 is a special and sensitive plastic used to verify exact position of heavy-ions traversal. Terminal deoxynucleotidyl transferase is an enzyme labeled with [3 H ] d ATP for detection of cellular DNA damage by autoradiography assay. Results: The track of heavy ions traversals presented by pit size was almost similar for all different doses of radiation. No pits to show the track of traversal were found in 20% of the cell nuclei of the irradiation. Apparently these fractions of cells wave not hit by heavy ions. Conclusion: This study indicated the possible usefulness of both the Cr-39 plastics and DNA labeling with Terminal deoxynucleotidyl transferase method for evaluating the biological effect of heavy-ions in comparison with low Linear Energy Transfer ionizing radiation

  10. A method for in situ absolute DD yield calibration of neutron time-of-flight detectors on OMEGA using CR-39-based proton detectors.

    Science.gov (United States)

    Waugh, C J; Rosenberg, M J; Zylstra, A B; Frenje, J A; Séguin, F H; Petrasso, R D; Glebov, V Yu; Sangster, T C; Stoeckl, C

    2015-05-01

    Neutron time of flight (nTOF) detectors are used routinely to measure the absolute DD neutron yield at OMEGA. To check the DD yield calibration of these detectors, originally calibrated using indium activation systems, which in turn were cross-calibrated to NOVA nTOF detectors in the early 1990s, a direct in situ calibration method using CR-39 range filter proton detectors has been successfully developed. By measuring DD neutron and proton yields from a series of exploding pusher implosions at OMEGA, a yield calibration coefficient of 1.09 ± 0.02 (relative to the previous coefficient) was determined for the 3m nTOF detector. In addition, comparison of these and other shots indicates that significant reduction in charged particle flux anisotropies is achieved when bang time occurs significantly (on the order of 500 ps) after the trailing edge of the laser pulse. This is an important observation as the main source of the yield calibration error is due to particle anisotropies caused by field effects. The results indicate that the CR-39-nTOF in situ calibration method can serve as a valuable technique for calibrating and reducing the uncertainty in the DD absolute yield calibration of nTOF detector systems on OMEGA, the National Ignition Facility, and laser megajoule.

  11. A method for in situ absolute DD yield calibration of neutron time-of-flight detectors on OMEGA using CR-39-based proton detectors

    International Nuclear Information System (INIS)

    Waugh, C. J.; Zylstra, A. B.; Frenje, J. A.; Séguin, F. H.; Petrasso, R. D.; Rosenberg, M. J.; Glebov, V. Yu.; Sangster, T. C.; Stoeckl, C.

    2015-01-01

    Neutron time of flight (nTOF) detectors are used routinely to measure the absolute DD neutron yield at OMEGA. To check the DD yield calibration of these detectors, originally calibrated using indium activation systems, which in turn were cross-calibrated to NOVA nTOF detectors in the early 1990s, a direct in situ calibration method using CR-39 range filter proton detectors has been successfully developed. By measuring DD neutron and proton yields from a series of exploding pusher implosions at OMEGA, a yield calibration coefficient of 1.09 ± 0.02 (relative to the previous coefficient) was determined for the 3m nTOF detector. In addition, comparison of these and other shots indicates that significant reduction in charged particle flux anisotropies is achieved when bang time occurs significantly (on the order of 500 ps) after the trailing edge of the laser pulse. This is an important observation as the main source of the yield calibration error is due to particle anisotropies caused by field effects. The results indicate that the CR-39-nTOF in situ calibration method can serve as a valuable technique for calibrating and reducing the uncertainty in the DD absolute yield calibration of nTOF detector systems on OMEGA, the National Ignition Facility, and laser megajoule

  12. A new method for studying the transport of radon and thoron in various building materials using CR-39 and LR-115 solid state nuclear track detectors

    International Nuclear Information System (INIS)

    Misdaq, M.A.; Ktata, A.; Bakhchi, A.

    2000-01-01

    Radon ( 222 Rn) and thoron ( 220 Rn) α-activities per unit volume were measured inside and outside different building materials by using two types of solid state nuclear track detectors (SSNTD) (CR-39 and LR-115 type II). In addition, the radon and thoron emanation coefficients of the studied materials were evaluated. Based on these data, the transport of radon and thoron across parallelepipedic blocks of the building materials could be investigated and radon and thoron global α-activities per unit volume outside different building material blocks were determined. Moreover, the diffusion length and the effective diffusion coefficient of radon in the building materials were evaluated and the total alpha activity due to radon in the atmospheres of different rooms consisting of different building materials was studied

  13. Track profile and range studies of heavy and light ions in CR-39: effect of thermal pre-treatment on etching characteristics

    International Nuclear Information System (INIS)

    Al-Najjar, S.A.R.; Bull, R.K.; Durrani, S.A.

    1982-01-01

    Sheets of CR 39 have been irradiated with 20 Ne, 32 S, 40 Ar, 56 Fe and 63 Cu ions at normal incidence to the surface of the sheets and at normal incidence to the edges. The profiles of the etched tracks have been observed side-on and measurements made of the variation of V (the ratio of track to bulk etching velocities) along the tracks and of the fully etched range of the tracks. Heating the plastic at 100 0 C prior to etching produces zones within the plastic having different bulk etching rates Vsub(B). An outer zone of low Vsub(B) is followed by a zone of much higher Vsub(B). This allows tracks to be readily etched to very large diameters, comparable in size to the breakdown spots produced by electrochemical etching. (author)

  14. Thermal studies on unirradiated and γ-irradiated polymer of allyl diglycol carbonate

    International Nuclear Information System (INIS)

    Kalsi, P.C.; Pandey, A.K.; Iyer, R.H.; Singh Mudher, K.D.

    1995-01-01

    The thermal decomposition of unirradiated and γ-irradiated (5.93-15.5 MRad dose range) allyl diglycol carbonate polymer (trade name, CR-39) was studied by thermogravimetry (TG) and differential thermal analysis (DTA). These studies indicate four main decomposition steps in CR-39 polymer in air. Assessment of the influence of radiation dose on the above range shows that while the 5.93 MRad γ-irradiated polymer CR-39 degrades in three steps, the 15.5 MRad γ-irradiated polymer degrades in only two steps. The kinetics of the different stages of degradation were also evaluated from the TG curves. Irradiation enhances the decomposition rate and the effect increases further with increasing radiation dose. The activation energy values calculated for all the decomposition stages decrease on irradiation

  15. 3D computation of the shape of etched tracks in CR-39 for oblique particle incidence and comparison with experimental results

    International Nuclear Information System (INIS)

    Doerschel, B.; Hermsdorf, D.; Reichelt, U.; Starke, S.; Wang, Y.

    2003-01-01

    Computation of the shape of etch pits needs to know the varying track etch rate along the particle trajectories. Experiments with alpha particles and 7 Li ions entering CR-39 detectors under different angles showed that this function is not affected by the inclination of the particle trajectory with respect to the normal on the detector surface. Track formation for oblique particle incidence can, therefore, be simulated using the track etch rates determined for perpendicular incidence. 3D computation of the track shape was performed applying a model recently described in literature. A special program has been written for computing the x,y,z coordinates of points on the etch pit walls. In addition, the etch pit profiles in sagittal sections as well as the contours of the etch pit openings on the detector surface have been determined experimentally. Computed and experimental results were in good agreement confirming the applicability of the 3D computational model in combination with the functions for the depth-dependent track etch rates determined experimentally

  16. Response of CR-39 to 0.9–2.5 MeV protons for KOH and NaOH etching solutions

    Energy Technology Data Exchange (ETDEWEB)

    Bahrami, F. [Department of Medical Radiation Engineering, Shiraz University, Shiraz (Iran, Islamic Republic of); Mianji, F., E-mail: fmianji@aeoi.org.ir [Nuclear Science & Technology Research Institute, Tehran (Iran, Islamic Republic of); Iran Nuclear Regulatory Authority, Tehran (Iran, Islamic Republic of); Faghihi, R. [Department of Medical Radiation Engineering, Shiraz University, Shiraz (Iran, Islamic Republic of); Taheri, M. [Iran Nuclear Regulatory Authority, Tehran (Iran, Islamic Republic of); Ansarinejad, A. [Nuclear Science & Technology Research Institute, Tehran (Iran, Islamic Republic of)

    2016-03-21

    In some circumstances passive detecting methods are the only or preferable measuring approaches. For instance, defining particles' energy profile inside the objects being irradiated with heavy ions and measuring fluence of neutrons or heavy particles in space missions are the cases covered by these methods. In this paper the ability of polyallyl diglycol carbonate (PADC) track detector (commercially known as CR-39) for passive spectrometry of proton particles is studied. Furthermore, the effect of KOH and NaOH as commonly used chemical etching solutions on the response of the detector is investigated. The experiments were carried out with protons in the energy range of 0.94–2.5 MeV generated by a Van de Graaff accelerator. Then, the exposed track dosimeters were etched in the two aforementioned etchants through similar procedure with the same normality of 6.25 N and the same temperature of 85 °C. Formation of the tracks was precisely investigated and the track diameters were recorded following every etching step for each solution using a multistage etching process. The results showed that the proposed method can be efficiently used for the spectrometry of protons over a wider dynamic range and with a reasonable accuracy. Moreover, NaOH and KOH outperformed each other over different regions of the proton energy range. The detection efficiency of both etchants was approximately 100%.

  17. Response of CR-39 to 0.9-2.5 MeV protons for KOH and NaOH etching solutions

    Science.gov (United States)

    Bahrami, F.; Mianji, F.; Faghihi, R.; Taheri, M.; Ansarinejad, A.

    2016-03-01

    In some circumstances passive detecting methods are the only or preferable measuring approaches. For instance, defining particles' energy profile inside the objects being irradiated with heavy ions and measuring fluence of neutrons or heavy particles in space missions are the cases covered by these methods. In this paper the ability of polyallyl diglycol carbonate (PADC) track detector (commercially known as CR-39) for passive spectrometry of proton particles is studied. Furthermore, the effect of KOH and NaOH as commonly used chemical etching solutions on the response of the detector is investigated. The experiments were carried out with protons in the energy range of 0.94-2.5 MeV generated by a Van de Graaff accelerator. Then, the exposed track dosimeters were etched in the two aforementioned etchants through similar procedure with the same normality of 6.25 N and the same temperature of 85 °C. Formation of the tracks was precisely investigated and the track diameters were recorded following every etching step for each solution using a multistage etching process. The results showed that the proposed method can be efficiently used for the spectrometry of protons over a wider dynamic range and with a reasonable accuracy. Moreover, NaOH and KOH outperformed each other over different regions of the proton energy range. The detection efficiency of both etchants was approximately 100%.

  18. Preliminary results of NAPL contamination in a disused industry in the city of Sao Paulo, Brazil, by radon evaluation with CR-39 detectors

    International Nuclear Information System (INIS)

    Mateus, Crislene; Pecequilo, Brigitte Roxana Soreanu

    2015-01-01

    Contaminated sites by NAPL (Non-Aqueous Phase-Liquids) may lead to safety risks to human health and to ecosystems, restrictions to urban development and decrease of real estate value. This work used the radon gas as an indicator for the analysis of subsurface soil gas, once this noble gas presents good solubility in a wide range of NAPL, being partially retained in the NAPL contamination. Therefore, a decrease of the activity of radon in the contaminated soil gas can be expected, due to the high capacity of partitioning of radon in NAPL, which allows that the NAPL retain part of the radon previously available in the soil pores. The survey was carried out at a disused industry, contaminated by low volatile NAPL, located at east of Sao Paulo city, in March/2015. Radon was evaluated by passive detection methodology with CR-39 solid state nuclear track detectors (SSNTD). Radon concentrations for the eight monitoring stations at non-contaminated locations in March/2015 varied from 16.4 ± 1.2 kBq.m -3 to 55 ± 4 kBq.m -3 . For the two monitoring stations assumed as contaminated locations in March/2015, radon concentrations were 1.17 ± 0.08 kBq.m -3 and 4.2 ± 0.3 kBq.m -3 , diminished in a range from 92% to 98% when compared with the results for the non-contaminated areas. (author)

  19. Measurement of D-3He proton yield with CR-39 as a diagnostic for inertial confinement fusion experiments. Final report, 7 January 1983-30 September 1984

    International Nuclear Information System (INIS)

    Blue, T.E.; Wehring, B.W.

    1985-04-01

    The first phase of our research project has as its main goal the development of an image analysis system for Solid State Nuclear Track Detectors (SSNTD) readout. Section I, of this report is an introduction to SSNTDs and image analysis systems for automatic track counting. The development of the image analysis system is described in Section II. The development of our foil holder system is described in Section III. The performance of an image analysis system can only be judged with respect to a particular type of image which is to be analyzed. In order to insure the workability of our image analysis system in analyzing CR-39 SSNTDs, we have made an effort to improve our etching system and our etch procedure. The development of our etching system and our etch procedure is outlined in Section IV. Also included in Section IV are images of protons and alpha particle tracks for our etch procedure. The performance of our image analysis system is reported in Section V for the proton and alpha particle tracks which are reported in Section IV. Also, the performance of the image analysis system is reported for some test images

  20. Preliminary results of NAPL contamination in a disused industry in the city of Sao Paulo, Brazil, by radon evaluation with CR-39 detectors

    Energy Technology Data Exchange (ETDEWEB)

    Mateus, Crislene; Pecequilo, Brigitte Roxana Soreanu, E-mail: crislene@ipen.br, E-mail: brigitte@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2015-07-01

    Contaminated sites by NAPL (Non-Aqueous Phase-Liquids) may lead to safety risks to human health and to ecosystems, restrictions to urban development and decrease of real estate value. This work used the radon gas as an indicator for the analysis of subsurface soil gas, once this noble gas presents good solubility in a wide range of NAPL, being partially retained in the NAPL contamination. Therefore, a decrease of the activity of radon in the contaminated soil gas can be expected, due to the high capacity of partitioning of radon in NAPL, which allows that the NAPL retain part of the radon previously available in the soil pores. The survey was carried out at a disused industry, contaminated by low volatile NAPL, located at east of Sao Paulo city, in March/2015. Radon was evaluated by passive detection methodology with CR-39 solid state nuclear track detectors (SSNTD). Radon concentrations for the eight monitoring stations at non-contaminated locations in March/2015 varied from 16.4 ± 1.2 kBq.m{sup -3} to 55 ± 4 kBq.m{sup -3}. For the two monitoring stations assumed as contaminated locations in March/2015, radon concentrations were 1.17 ± 0.08 kBq.m{sup -3} and 4.2 ± 0.3 kBq.m{sup -3}, diminished in a range from 92% to 98% when compared with the results for the non-contaminated areas. (author)

  1. Preliminary study on 2-dimensional distributions of 10B reaction rate in a water phantom with boron-doped CR-39 for 7Li(p, n)7Be neutrons by 1.95 MeV protons

    International Nuclear Information System (INIS)

    Hasegawa, Y.; Tanaka, K.; Tsuruta, T.

    2000-01-01

    In an Accelerator-based neutron irradiation field using 7 Li(p, n) 7 Be neutrons by 1.95 MeV protons, the distributions of 10 B reaction rates and thermal neutron fluence in a water phantom were measured using Boron-doped CR-39 and Au activation analysis, respectively. Comparing the results of the measurements, we discussed the validity of the evaluation method of 10 B reaction rate using thermal neutron fluence. (author)

  2. Enhancements of the memory margin and the stability of an organic bistable device due to a graphene oxide:mica nanocomposite sandwiched between two polymer (9-vinylcarbazole) buffer layers

    Science.gov (United States)

    Kim, Woo Kyum; Wu, Chaoxing; Lee, Dea Uk; Kim, Hyoun Woo; Kim, Tae Whan

    2018-01-01

    Current-voltage (I-V) curves for the Al/polymer (9-vinylcarbazole) (PVK)/graphene oxide (GO):mica/PVK/indium-tin oxide (ITO) devices at 300 K showed a current bistability with a maximum high conductivity (ON)/low conductivity (OFF) ratio of 2 × 104, which was approximately 10 times larger than that of the device without a PVK layer. The endurance number of ON/OFF switchings for the Al/PVK/GO:mica/PVK/ITO device was 1 × 102 cycles, which was 20 times larger than that for the Al/GO:mica/ITO device. The ;erase; voltages were distributed between 2.3 and 3 V, and the ;write; voltages were distributed between -1.2 and -0.5 V. The retention time for the Al/PVK/GO:mica/PVK/ITO device was above 1 × 104 s, indicative of the memory stability of the device. The carrier transport mechanisms occurring in the Al/PVK/GO:mica/PVK/ITO and the Al/GO:mica/ITO devices are described on the basis of the I-V results and the energy band diagrams.

  3. Study of the weekly irrigation cycle of a cultivated field in a semi-arid area (Marrakech region, Morocco) by using CR-39 and LR-115 II track detectors and radon as a natural tracer

    International Nuclear Information System (INIS)

    Misdaq, M.A.; Essaouif, Z.

    2007-01-01

    Uranium ( 238 U) and thorium ( 232 Th) concentrations were measured in the soil of a cultivated field situated in a semi-arid area (Marrakech, Morocco) by using CR-39 and LR-115 type II solid state nuclear track detectors (SSNTDs). The same track detectors were used for measuring alpha- and beta-activities due to radon and thoron gases emanating from the soil of the studied irrigated agricultural field. The influence of the humidity (soil water content), soil depth and climate conditions on the weekly irrigation cycle of the studied cultivated field was investigated by exploiting radon measurements

  4. CR-39 track detector calibration for H, He, and C ions from 0.1-0.5 MeV up to 5 MeV for laser-induced nuclear fusion product identification.

    Science.gov (United States)

    Baccou, C; Yahia, V; Depierreux, S; Neuville, C; Goyon, C; Consoli, F; De Angelis, R; Ducret, J E; Boutoux, G; Rafelski, J; Labaune, C

    2015-08-01

    Laser-accelerated ion beams can be used in many applications and, especially, to initiate nuclear reactions out of thermal equilibrium. We have experimentally studied aneutronic fusion reactions induced by protons accelerated by the Target Normal Sheath Acceleration mechanism, colliding with a boron target. Such experiments require a rigorous method to identify the reaction products (alpha particles) collected in detectors among a few other ion species such as protons or carbon ions, for example. CR-39 track detectors are widely used because they are mostly sensitive to ions and their efficiency is near 100%. We present a complete calibration of CR-39 track detector for protons, alpha particles, and carbon ions. We give measurements of their track diameters for energy ranging from hundreds of keV to a few MeV and for etching times between 1 and 8 h. We used these results to identify alpha particles in our experiments on proton-boron fusion reactions initiated by laser-accelerated protons. We show that their number clearly increases when the boron fuel is preformed in a plasma state.

  5. Estimation of track registration efficiency in solution medium and study of gamma irradiation effects on the bulk-etch rate and the activation energy for bulk etching of CR-39 (DOP) Solid State Nuclear Track Detector

    International Nuclear Information System (INIS)

    Kalsi, P.C.

    2010-01-01

    The fission track registration efficiency of diethylene glycol bis allyl carbonate (dioctyl phthalate doped) (CR-39 (DOP)) solid state nuclear track detector (SSNTD) in solution medium (K wet ) has been experimentally determined and is found to be (9.7 ± 0.5).10 -4 cm. This is in good agreement with the values of other SSNTDs. The gamma irradiation effects in the dose range of 50.0-220.0 kGy on the bulk etch rate, V b and the activation energy for bulk etching, E of this solid state nuclear track detector (SSNTD) have also been studied. It is observed that the bulk etch rates increase and the activation energies for bulk etching decrease with the increase in gamma dose. These results have been explained on the basis of scission of the detector due to gamma irradiation

  6. Síntese de fotoprotetores e sua imobilização em poli(metacrilato de metilo: um projeto integrado de química orgânica, química de polímeros e fotoquímica Sunscreen synthesis and their immobilisition on polymethylmethacrylate: an integrated project in organic chemistry, polymer chemistry and photochemistry

    Directory of Open Access Journals (Sweden)

    Dina Maria B. Murtinho

    2010-01-01

    Full Text Available Dibenzalacetone and other aldol condensation products are known sunscreens commonly used in cosmetics. This type of compounds can easily be prepared in an Organic Chemistry Lab by reaction of aldehydes with ketones in basic medium. These compounds can be incorporated in poly(methyl methacrylate and used as UV light absorbers, for example in sunglasses. This project has the advantage of using inexpensive reagents which are readily available in Chemistry Laboratories. This experiment can also be a base starting point for discussions of organic, polymer and photochemistry topics.

  7. Mica fission detectors

    International Nuclear Information System (INIS)

    Wong, C.; Anderson, J.D.; Hansen, L.; Lehn, A.V.; Williamson, M.A.

    1977-01-01

    The present development status of the mica fission detectors is summarized. It is concluded that the techniques have been refined and developed to a state such that the mica fission counters are a reliable and reproducible detector for fission events

  8. Differences between tethered polyelectrolyte chains adsorbed onto bare mica and hydrophobically modified mica, comparison with theory.

    Science.gov (United States)

    Balastre, Marc; Tamashiro, Mario N.; Hernandez, Ernesto; Pincus, Philip; Tirrell, Matthew

    2001-03-01

    End-grafted polymers generated from the adsorption of asymmetric diblock copolymers on solid surface play an important role in many areas of science and technology. While the small insoluble block acts as an anchor, the charged soluble block confers useful properties to the surface. This study looks at tethered layers of poly(styrene sulfonate)/poly(t-butyl styrene) (PtBS-PSS) adsorbed on both mica (hydrophilic) and octadecyltriethoxysilane (OTE) modified mica (hydrophobic). Normal compressing forces at two different constant grafting densities (bare and modified mica) were measured with the surface force apparatus and compared with theoretical prediction. The effect of salt concentration (Cs) upon the thickness of the self-assembled layers (Lo) was measured in each case. For adsorption of diblock copolymers onto OTE the resulting scaling relationship is much closer to the brush theory, Lo Cs-1/3. This result suggests that the adsorbed amount on mica is not high enough to form a brush.

  9. Application of spectroscopic methods to the study of ionizing radiation effects in polymers

    International Nuclear Information System (INIS)

    Jimenez P, G.

    1995-01-01

    In general the interaction of ionizing radiation with polymers generates physic-chemical changes. Aiming to quantity these changes, three spectroscopic analytical techniques were used (UV, IR and EPR) and the chemical corrosion technique was used for three DSTN (CR39, Lexan and Makrofol) which were exposed to two radiation types: electrons and gammas. The effects of radiation are compared. Also a correlation between the UV and Vg results in function of dose is presented. The possible causes of the increase in chemical corrosion are discussed. (Author)

  10. Ion beam techniques for analyzing polymers irradiated by ions

    International Nuclear Information System (INIS)

    Rickards, J.; Zironi, E.P.; Andrade, E.; Dominguez, B.

    1992-01-01

    In the study of the effects of ion beam irradiation of polymers very large doses can be administered in short times. Thousands of MGy can be produced in a small volume of a sample in a few minutes by bombarding with typical ion beam currents. For instance, in an experiment done to observe the effects of 750 keV proton irradiation PVC, using a collimator of 1 mm diameter, 1 μC of charge integration deposits a dose of 50 MGy. The use of ion beams also opens up the possibility of using the same beam for irradiation and for analysis of the effects, using the well known ion beam analysis techniques. PIXE allows the measurement of chlorine in PVC. Polymers containing fluorine can be measured with the resonant nuclear reaction (RNR) technique, which is specific only to certain elements. The amount of hydrogen in the sample and its profile can be obtained using energy recoil detection analysis (ERDA); carbon, oxygen, and nitrogen can be measured and profiled using Rutherford backscattering (RBS) and also using the (d,p) and (d, α) nuclear reactions (NR). Loss of mass is one effect that can be studied using these techniques. It was studied in two different polymers, PVC and CR-39, in order to determine carbon buildup during ion irradiation. It was concluded that carbon builds up following different mechanisms in these two materials, due to the different possibilities of forming volatile compounds. It is also suggested that CR-39 should be a good material for ion beam lithography. (author)

  11. Discovery of an 'internal heating effect' during electrochemical etching of polymeric dosimeters: a study of polymer characteristics

    International Nuclear Information System (INIS)

    Sohrabi, M.

    1986-01-01

    This paper investigates the importance of the internal heating effect by studying the role of different polymer physical and chemical characteristics (composition, effective foil size, thickness and electrical properties), on the rate of heating or temperature rise responses for cellulose tri-acetate (CTA), cellulose acetate (CA), allyl diglycol carbonate (CR-39), cellulose nitrate (CN), cellulose acetate butyrate (CAB), polyester (PES), polycarbonate (PC) and polyethylene (PE). Efforts have been made to justify the observed effects by different mechanisms such as dielectric loss, electro-osmosis, dielectrophoresis, and electrostriction. (author)

  12. Polymer films

    Science.gov (United States)

    Granick, Steve; Sukhishvili, Svetlana A.

    2004-05-25

    A film contains a first polymer having a plurality of hydrogen bond donating moieties, and a second polymer having a plurality of hydrogen bond accepting moieties. The second polymer is hydrogen bonded to the first polymer.

  13. Particularization of alpha contamination using CR-39 track detectors

    Indian Academy of Sciences (India)

    detecting devices and as a passive system to detect alpha contamination on different sur- faces. This work presents ... these plastic detectors can be cut into sizes and shapes according to the specific area that has to be ... of nuclear track materials observed under a microscope, after chemical etching for the same time and ...

  14. Tribological performance of polymer composites used in electrical ...

    Indian Academy of Sciences (India)

    engineering applications. ZAFER DEMIR. Anadolu University, Eskisehir, Turkey. MS received 28 December 2011; revised 13 March 2012. Abstract. Sliding wear performance of 20% mica-filled polyamide 6 (PA6 + 20% mica) and 20% short glass fibre- reinforced polysulphone (PSU + 20 GFR) polymer composites used in ...

  15. Application of spectroscopic methods to the study of ionizing radiation effects in polymers; Aplicacion de metodos espectroscopicos para estudiar efectos de la radiacion en polimeros

    Energy Technology Data Exchange (ETDEWEB)

    Jimenez P, G

    1996-12-31

    In general the interaction of ionizing radiation with polymers generates physic-chemical changes. Aiming to quantity these changes, three spectroscopic analytical techniques were used (UV, IR and EPR) and the chemical corrosion technique was used for three DSTN (CR39, Lexan and Makrofol) which were exposed to two radiation types: electrons and gammas. The effects of radiation are compared. Also a correlation between the UV and Vg results in function of dose is presented. The possible causes of the increase in chemical corrosion are discussed. (Author).

  16. Biodegradable Polymers

    OpenAIRE

    Vroman, Isabelle; Tighzert, Lan

    2009-01-01

    Biodegradable materials are used in packaging, agriculture, medicine and other areas. In recent years there has been an increase in interest in biodegradable polymers. Two classes of biodegradable polymers can be distinguished: synthetic or natural polymers. There are polymers produced from feedstocks derived either from petroleum resources (non renewable resources) or from biological resources (renewable resources). In general natural polymers offer fewer advantages than synthetic polymers. ...

  17. Polymer compound

    NARCIS (Netherlands)

    1995-01-01

    A Polymer compound comprising a polymer (a) that contains cyclic imidesgroups and a polymer (b) that contains monomer groups with a 2,4-diamino-1,3,5-triazine side group. According to the formula (see formula) whereby themole percentage ratio of the cyclic imides groups in the polymer compoundwith

  18. Biotermodin?mica en animales

    OpenAIRE

    Granados Moreno, Jairo Enrique

    2014-01-01

    El documento presenta como la termodin?mica es la ciencia que estudia las relaciones entre calor y las dem?s formas de transferencias de energ?a. Se explica que toda transformaci?n biofisicoqu?mica implica, generalmente, un cambio energ?tico. Se tratan los conceptos de temperatura, escalas de temperatura, calor, calor de combusti?n, postulados de la termodin?mica, entrop?a y energ?a libre metab?lica

  19. Polymer electronics

    CERN Document Server

    Hsin-Fei, Meng

    2013-01-01

    Polymer semiconductor is the only semiconductor that can be processed in solution. Electronics made by these flexible materials have many advantages such as large-area solution process, low cost, and high performance. Researchers and companies are increasingly dedicating time and money in polymer electronics. This book focuses on the fundamental materials and device physics of polymer electronics. It describes polymer light-emitting diodes, polymer field-effect transistors, organic vertical transistors, polymer solar cells, and many applications based on polymer electronics. The book also disc

  20. Farmacogenómica

    OpenAIRE

    Izaguirre Pasquel, Victor

    2014-01-01

    La farmacogenómica, área de investigación innovadora y de reciente desarrollo, surge para explicar las diferencias interindividuales en la respuesta a los fármacos y evitar reacciones adversas y costes innecesarios. Básicamente, esta nueva ciencia tiene dos orientaciones, una centrada en el diseño de fármacos para el tratamiento de una enfermedad que tiene un marcado carácter genético y otra, en el diseño de fármacos con menor toxicidad para pacientes con deficiencias y/o alteraciones génicas...

  1. PHOTOREFRACTIVE POLYMERS

    NARCIS (Netherlands)

    Morichere, D; Malliaras, G.G; Krasnikov, V.V.; Bolink, H.J; Hadziioannou, G

    The use of polymers as photorefractive materials offers many advantages : flexibility in synthesis, doping, processing and low cost. The required functionalities responsible for photorefractivity, namely charge generation, transport, trapping and linear electrooptic effect are given in the polymer

  2. Photorefractive polymers

    NARCIS (Netherlands)

    Bolink, Hendrik Jan; Hadziioannou, G

    1997-01-01

    This thesis describes the synthesis and properties of photorefractive polymers. Photorefractive polymers are materials in which the refractive index can be varied by the interaction with light. Unlike in numerous other photosensitive materials, in photorefractive materials this occurs via

  3. Polymer Brushes

    NARCIS (Netherlands)

    Vos, de W.M.; Kleijn, J.M.; Keizer, de A.; Cosgrove, T.; Cohen Stuart, M.A.

    2010-01-01

    A polymer brush can be defined as a dense array of polymers end-attached to an interface that stretch out into the surrounding medium. Polymer brushes have been investigated for the past 30 years and have shown to be an extremely useful tool to control interfacial properties. This review is intended

  4. electroquímica

    Directory of Open Access Journals (Sweden)

    HÉCTOR FABIÁN RESTREPO

    2005-01-01

    Full Text Available En este trabajo se estudió el efecto de la temperatura y la concentración inicial de la anilina sobre la morfología y la conductividad de polianilina obtenida por electropolimerización con voltametría cíclica en soportes de carbón vítreo. La sal de anilina inicial se caracterizó mediante análisis infrarrojo (I.R. La morfología de la polianilina obtenida se analizó por medio de microscopio electrónico (S.E.M., y la conductividad mediante impedancia electroquímica (E.I.S.. Los resultados mostraron un aumento en la velocidad de polimerización y cambios en la morfología del polímero con el aumento de la temperatura y de la concentración del monómero. Los análisis S.E.M. mostraron tres tipos de formaciones poliméricas para los diferentes parámetros de polimerización: lentejuelas, filamentos y gránulos. Los resultados de EIS muestran mayor conductividad y alta capacitancia del polímero a mayores temperaturas y concentraciones.

  5. Polymer Electrolytes

    Science.gov (United States)

    Hallinan, Daniel T.; Balsara, Nitash P.

    2013-07-01

    This review article covers applications in which polymer electrolytes are used: lithium batteries, fuel cells, and water desalination. The ideas of electrochemical potential, salt activity, and ion transport are presented in the context of these applications. Potential is defined, and we show how a cell potential measurement can be used to ascertain salt activity. The transport parameters needed to fully specify a binary electrolyte (salt + solvent) are presented. We define five fundamentally different types of homogeneous electrolytes: type I (classical liquid electrolytes), type II (gel electrolytes), type III (dry polymer electrolytes), type IV (dry single-ion-conducting polymer electrolytes), and type V (solvated single-ion-conducting polymer electrolytes). Typical values of transport parameters are provided for all types of electrolytes. Comparison among the values provides insight into the transport mechanisms occurring in polymer electrolytes. It is desirable to decouple the mechanical properties of polymer electrolyte membranes from the ionic conductivity. One way to accomplish this is through the development of microphase-separated polymers, wherein one of the microphases conducts ions while the other enhances the mechanical rigidity of the heterogeneous polymer electrolyte. We cover all three types of conducting polymer electrolyte phases (types III, IV, and V). We present a simple framework that relates the transport parameters of heterogeneous electrolytes to homogeneous analogs. We conclude by discussing electrochemical stability of electrolytes and the effects of water contamination because of their relevance to applications such as lithium ion batteries.

  6. Star Polymers.

    Science.gov (United States)

    Ren, Jing M; McKenzie, Thomas G; Fu, Qiang; Wong, Edgar H H; Xu, Jiangtao; An, Zesheng; Shanmugam, Sivaprakash; Davis, Thomas P; Boyer, Cyrille; Qiao, Greg G

    2016-06-22

    Recent advances in controlled/living polymerization techniques and highly efficient coupling chemistries have enabled the facile synthesis of complex polymer architectures with controlled dimensions and functionality. As an example, star polymers consist of many linear polymers fused at a central point with a large number of chain end functionalities. Owing to this exclusive structure, star polymers exhibit some remarkable characteristics and properties unattainable by simple linear polymers. Hence, they constitute a unique class of technologically important nanomaterials that have been utilized or are currently under audition for many applications in life sciences and nanotechnologies. This article first provides a comprehensive summary of synthetic strategies towards star polymers, then reviews the latest developments in the synthesis and characterization methods of star macromolecules, and lastly outlines emerging applications and current commercial use of star-shaped polymers. The aim of this work is to promote star polymer research, generate new avenues of scientific investigation, and provide contemporary perspectives on chemical innovation that may expedite the commercialization of new star nanomaterials. We envision in the not-too-distant future star polymers will play an increasingly important role in materials science and nanotechnology in both academic and industrial settings.

  7. Polymer chemistry (revised edition)

    International Nuclear Information System (INIS)

    Kim, Jae Mum

    1987-02-01

    This book deals with polymer chemistry, which is divided into fourteen chapters. The contents of this book are development of polymer chemistry, conception of polymer, measurement of polymer chemistry, conception of polymer, measurement of polymer, molecule structure of polymer, thermal prosperities of solid polymer, basic theory of polymerization, radical polymerization, ion polymerization, radical polymerization, copolymerization, polymerization by step-reaction, polymer reaction, crown polymer and inorganic polymer on classification and process of creation such as polymeric sulfur and carbon fiber.

  8. Polymer Nanocomposites

    Indian Academy of Sciences (India)

    methods for the synthesis of polymer nanocomposites. In this article we .... ers, raw materials recovery, drug delivery and anticorrosion .... region giving rise to dose-packed absorption bands called an IR ... using quaternary ammonium salts.

  9. Polymer nanocomposites: polymer and particle dynamics

    KAUST Repository

    Kim, Daniel; Srivastava, Samanvaya; Narayanan, Suresh; Archer, Lynden A.

    2012-01-01

    Polymer nanocomposites containing nanoparticles smaller than the random coil size of their host polymer chains are known to exhibit unique properties, such as lower viscosity and glass transition temperature relative to the neat polymer melt. It has

  10. Effect of synthetic mica on the thermal properties of poly(lactic acid

    Directory of Open Access Journals (Sweden)

    Diego Holanda Saboya Souza

    2014-01-01

    Full Text Available Poly(lactic acid/Somasif fluoromica nanocomposites were prepared by melt blending and their thermal properties investigated by DSC, TGA and DMA. Three different types of synthetic mica (Somasif ME-100, Somasif MAE and Somasif MPE were used at different contents (2.5, 5.0 and 7.5 wt %. The melt blending of PLA and these micas is characterized by a considerable reduction in the matrix molecular weight, which decreases when the nanofiller content is increased. For all nanocomposites, the thermal stability increases when mica is added to the polymer, with the Somasif MPE, producing the highest increase of the degradation temperature and highest reduction of Tg.

  11. Antimocrobial Polymer

    Science.gov (United States)

    McDonald, William F.; Huang, Zhi-Heng; Wright, Stacy C.

    2005-09-06

    A polymeric composition having antimicrobial properties and a process for rendering the surface of a substrate antimicrobial are disclosed. The composition comprises a crosslinked chemical combination of (i) a polymer having amino group-containing side chains along a backbone forming the polymer, (ii) an antimicrobial agent selected from quaternary ammonium compounds, gentian violet compounds, substituted or unsubstituted phenols, biguanide compounds, iodine compounds, and mixtures thereof, and (iii) a crosslinking agent containing functional groups capable of reacting with the amino groups. In one embodiment, the polymer is a polyamide formed from a maleic anhydride or maleic acid ester monomer and alkylamines thereby producing a polyamide having amino substituted alkyl chains on one side of the polyamide backbone; the crosslinking agent is a phosphine having the general formula (A)3P wherein A is hydroxyalkyl; and the antimicrobial agent is chlorhexidine, dimethylchlorophenol, cetyl pyridinium chloride, gentian violet, triclosan, thymol, iodine, and mixtures thereof.

  12. Polymer electronics

    CERN Document Server

    Geoghegan, Mark

    2013-01-01

    Polymer electronics is the science behind many important new developments in technology, such as the flexible electronic display (e-ink) and many new developments in transistor technology. Solar cells, light-emitting diodes, and transistors are all areas where plastic electronics is likely to, or is already having, a serious impact on our daily lives. With polymer transistors and light-emitting diodes now being commercialised, there is a clear need for a pedagogic text thatdiscusses the subject in a clear and concise fashion suitable for senior undergraduate and graduate students. The content

  13. Polymer physics

    CERN Document Server

    Gedde, Ulf W

    1999-01-01

    This book is the result of my teaching efforts during the last ten years at the Royal Institute of Technology. The purpose is to present the subject of polymer physics for undergraduate and graduate students, to focus the fundamental aspects of the subject and to show the link between experiments and theory. The intention is not to present a compilation of the currently available literature on the subject. Very few reference citations have thus been made. Each chapter has essentially the same structure: starling with an introduction, continuing with the actual subject, summarizing the chapter in 30D-500 words, and finally presenting problems and a list of relevant references for the reader. The solutions to the problems presented in Chapters 1-12 are given in Chapter 13. The theme of the book is essentially polymer science, with the exclusion of that part dealing directly with chemical reactions. The fundamentals in polymer science, including some basic polymer chemistry, are presented as an introduction in t...

  14. Antimicrobial polymers.

    Science.gov (United States)

    Jain, Anjali; Duvvuri, L Sailaja; Farah, Shady; Beyth, Nurit; Domb, Abraham J; Khan, Wahid

    2014-12-01

    Better health is basic requirement of human being, but the rapid growth of harmful pathogens and their serious health effects pose a significant challenge to modern science. Infections by pathogenic microorganisms are of great concern in many fields such as medical devices, drugs, hospital surfaces/furniture, dental restoration, surgery equipment, health care products, and hygienic applications (e.g., water purification systems, textiles, food packaging and storage, major or domestic appliances etc.) Antimicrobial polymers are the materials having the capability to kill/inhibit the growth of microbes on their surface or surrounding environment. Recently, they gained considerable interest for both academic research and industry and were found to be better than their small molecular counterparts in terms of enhanced efficacy, reduced toxicity, minimized environmental problems, resistance, and prolonged lifetime. Hence, efforts have focused on the development of antimicrobial polymers with all desired characters for optimum activity. In this Review, an overview of different antimicrobial polymers, their mechanism of action, factors affecting antimicrobial activity, and application in various fields are given. Recent advances and the current clinical status of these polymers are also discussed. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. A microwave inverse Cerenkov Accelerator (MICA)

    International Nuclear Information System (INIS)

    Hirshfield, Jay L.

    1999-01-01

    The objective of this Phase II SBIR research program was to complete the final design originated during Phase I for a prototype Microwave Inverse Cerenkov Accelerator (MICA), to fabricate the-prototype MICA, and to test its performance as an electron accelerator. This report contains details of the design, predictions of accelerator performance, results of cold tests on the MICA structure, and details of the installation of MICA on the Yale Beam Physics Laboratory 6-MeV beamline. Discussion of future work is also included

  16. Polymer blends

    Energy Technology Data Exchange (ETDEWEB)

    Allen, Scott D.; Naik, Sanjeev

    2017-08-22

    The present invention provides, among other things, extruded blends of aliphatic polycarbonates and polyolefins. In one aspect, provided blends comprise aliphatic polycarbonates such as poly(propylene carbonate) and a lesser amount of a crystalline or semicrystalline polymer. In certain embodiments, provided blends are characterized in that they exhibit unexpected improvements in their elongation properties. In another aspect, the invention provides methods of making such materials and applications of the materials in applications such as the manufacture of consumer packaging materials.

  17. Mechanistic Indicators of Childhood Asthma (MICA) Study

    Science.gov (United States)

    The Mechanistic Indicators of Childhood Asthma (MICA) Study has been designed to incorporate state-of-the-art technologies to examine the physiological and environmental factors that interact to increase the risk of asthmatic responses. MICA is primarily a clinically-bases obser...

  18. Towards completely miscible PMMA nanocomposites reinforced by shear-stiff, nano-mica.

    Science.gov (United States)

    Ziadeh, Mazen; Weiss, Stephan; Fischer, Bianca; Förster, Stephan; Altstädt, Volker; Müller, Axel H E; Breu, Josef

    2014-07-01

    Optimizing the reinforcement of polymers with nanoplatelets requires optimization of the aspect ratio and the moduli of the filler while providing a complete stress transfer. Employing a novel shear-stiff, nano-mica with large aspect ratio, we focus on maximizing the interfacial interaction between filler and matrix. External surfaces of the nano-mica were selectively modified by a polycationic macro-initiator and two PMMA-polymer brushes of length below and above critical entanglement length, respectively, and the mechanical properties of the three PMMA nanocomposites were measured. The multiple electrostatic anchoring groups of the macro-initiator not only provide reliable adhesion but at the same time allow the variation of the degree of protonation providing a local match between the charge densities of the clay surface and the adsorbed macro-initiator. PMMA coating of the nano-mica via surface initiated polymerization yielded long-term stable suspensions in THF that showed birefringence of a nematic phase. Solution blending of the PMMA coated nano-mica allows for dispersing single clay tactoids in the translucent PMMA nanocomposites at 5 wt% clay loading as determined by transmission electron microscopy (TEM). Although significantly improved mechanical properties could be achieved as compared to nanocomposites made with conventional clay fillers, the full potential - as expressed by Halpin-Tsai equations - of the PMMA coated nano-mica can still not be completely utilized. This is attributed to the non-wetting character of the densely packed PMMA brushes attached to planar nanoplatelets. Copyright © 2014 Elsevier Inc. All rights reserved.

  19. Mutaciones dinámicas

    Directory of Open Access Journals (Sweden)

    Cesar A. Parra

    1994-10-01

    Full Text Available EI descubrimiento de repeticiones amplificadas de trinucleótidos variables en número, en pacientes con distrofia miotónica, síndrome de X-frágil, corea de Huntington y enfermedad de Kennedy, al igual que alteraciones en dinucleótidos del DNA microsatélite en pacientes con carcinoma proximal de colon, ha dado origen al concepto de mutaciones dinámicas. Esto representa una nueva avenida en teoría genética contemporánea que explica fenómenos como lo anticipación y la paradoja de Sherman que se salen del patrón mendeliano clásico.

  20. Natural polymers: an overview

    CSIR Research Space (South Africa)

    John, MJ

    2012-08-01

    Full Text Available The scarcity of natural polymers during the world war years led to the development of synthetic polymers like nylon, acrylic, neoprene, styrene-butadiene rubber (SBR) and polyethylene. The increasing popularity of synthetic polymers is partly due...

  1. Algoritmos para genómica comparativa

    OpenAIRE

    Figueiras, Vasco da Rocha

    2010-01-01

    Com o surgimento da Genómica e da Proteómica, a Bioinformática conduziu a alguns dos avanços científicos mais relevantes do século XX. A Unidade de Investigação e Desenvolvimento do Biocant, parque biotecnológico de Cantanhede, assume actualmente o papel de motor no desenvolvimento da Genómica. O Biocant possui um importante sequenciador de larga escala que permite armazenar um elevado número de genomas, nomeadamente, genomas de bactérias. O estudo proposto reflecte a necessidade do Bio...

  2. Polymer dynamics from synthetic polymers to proteins

    Indian Academy of Sciences (India)

    Keywords. Polymer dynamics; reptation; domain dynamics biomolecules. Abstract. Starting from the standard model of polymer motion - the Rouse model - we briefly present some key experimental results on the mesoscopic dynamics of polymer systems. We touch the role of topological confinement as expressed in the ...

  3. breve panorámica

    Directory of Open Access Journals (Sweden)

    Sandra M. Camelo Roa

    2005-01-01

    Full Text Available Desde los terrenos de la psicoinmunología, la presente revisión se propone una mirada panorámica a sus principales postulados, líneas de investigación, resultados y perspectivas. Para ello, inicialmente se abordaron algunos aspectos históricos de la relación entre la vida psíquica y la salud; posteriormente, se revisaron aspectos como la fisiología del sistema inmune especificando los tipos de inmunidad adquirida e inmunidad natural. Temas como las interacciones entre el sistema inmune y cerebro fueron revisados desde la evidencia experimental y resumidos en cuatro grupos: condicionamiento de la respuesta inmune, lesiones cerebrales, estrés e inmunidad y emociones e inmunidad. Finalmente, se contemplaron algunos métodos para el estudio del sistema inmune como los ensayos in vitro, citometría de flujo y ensayos in vivo. Como observaciones finales, toda la literatura sugiere que existe relación entre el sistema inmune y diversos estados psíquicos. Pero aún surgen preguntas de esta indiscutible relación sin tener una respuesta satisfactoria.

  4. MICA: Multiple interval-based curve alignment

    Science.gov (United States)

    Mann, Martin; Kahle, Hans-Peter; Beck, Matthias; Bender, Bela Johannes; Spiecker, Heinrich; Backofen, Rolf

    2018-01-01

    MICA enables the automatic synchronization of discrete data curves. To this end, characteristic points of the curves' shapes are identified. These landmarks are used within a heuristic curve registration approach to align profile pairs by mapping similar characteristics onto each other. In combination with a progressive alignment scheme, this enables the computation of multiple curve alignments. Multiple curve alignments are needed to derive meaningful representative consensus data of measured time or data series. MICA was already successfully applied to generate representative profiles of tree growth data based on intra-annual wood density profiles or cell formation data. The MICA package provides a command-line and graphical user interface. The R interface enables the direct embedding of multiple curve alignment computation into larger analyses pipelines. Source code, binaries and documentation are freely available at https://github.com/BackofenLab/MICA

  5. 21 CFR 73.1350 - Mica-based pearlescent pigments.

    Science.gov (United States)

    2010-04-01

    ... LISTING OF COLOR ADDITIVES EXEMPT FROM CERTIFICATION Drugs § 73.1350 Mica-based pearlescent pigments. (a) Identity. (1) The color additive is formed by depositing titanium and/or iron salts onto mica, followed by...; titanium dioxide and iron oxide on mica. Mica used to manufacture the color additive shall conform in...

  6. 21 CFR 73.350 - Mica-based pearlescent pigments.

    Science.gov (United States)

    2010-04-01

    ... LISTING OF COLOR ADDITIVES EXEMPT FROM CERTIFICATION Foods § 73.350 Mica-based pearlescent pigments. (a) Identity. (1) The color additive is formed by depositing titanium salts onto mica, followed by heating to produce titanium dioxide on mica. Mica used to manufacture the color additive shall conform in identity to...

  7. Química general II

    OpenAIRE

    Olba Torrent, Amparo

    2018-01-01

    El document forma part dels materials docents programats mitjançant l'ajut del Servei de Política Lingüística de la Universitat de València Temes de l'assignatura: Química general II del primer curs del Grau de Química Topics of the course: General Chemistry II in the first year of the Degree in Chemistry

  8. Self-Assembling of Tetradecylammonium Chain on Swelling High Charge Micas (Na-Mica-3 and Na-Mica-2): Effect of Alkylammonium Concentration and Mica Layer Charge.

    Science.gov (United States)

    Pazos, M Carolina; Cota, Agustín; Osuna, Francisco J; Pavón, Esperanza; Alba, María D

    2015-04-21

    A family of tetradecylammonium micas is synthesized using synthetic swelling micas with high layer charge (Na(n)Si(8-n)Al(n)Mg6F4O20·XH2O, where n = 2 and 3) exchanged with tetradecylammonium cations. The molecular arrangement of the surfactant is elucidated on the basis of XRD patterns and DTA. The ordering conformation of the surfactant molecules into the interlayer space of micas is investigated by IR/FT, (13)C, (27)Al, and (29)Si MAS NMR. The structural arrangement of the tetradecylammonium cation in the interlayer space of high-charge micas is more sensitive to the effect of the mica layer charge at high concentration. The surfactant arrangement is found to follow the bilayer-paraffin model for all values of layer charge and surfactant concentration. However, at initial concentration below the mica CEC, a lateral monolayer is also observed. The amount of ordered conformation all-trans is directly proportional to the layer charge and surfactant concentration.

  9. Two-mica granites of northeastern Nevada.

    Science.gov (United States)

    Lee, D.E.; Kistler, R.W.; Friedman, I.; Van Loenen, R. E.

    1981-01-01

    The field settings are described and analytical data are presented for six two-mica granites from NE Nevada. High delta 18O and 87Sr/86Sr values indicate that all are S-type granite, derived from continental crust. The major element chemistry and accessory mineral contents of these rocks also are characteristic of S-type granites. Chemical, X ray, and other data are presented for the micas recovered from these granites. The muscovites are notably high in Fe2O3, FeO, and MgO. Except for one hydrobiotite, each of the biotites has an MgO content near 6.0 wt%. Two different types of two-mica granites are recognized in the area of this study. One type is distinguished by the presence of many biotite euhedra within muscovite phenocrysts and by an unusual suite of accessory minerals completely devoid of opaque oxides. This type probably resulted from anatexis of late Precambrian argillites under conditions of relatively low oxygen fugacity, along a line that roughly coincides with the westward disappearance of continental basement. In the other textural type of two-mica granite the micas are equigranular and there is a greater variety of accessory minerals. The magmatic evolution of this type also appears to reflect the influence of late Precambrian argillites; there may be age differences between the two types of two-mica granites.-Author

  10. Semi-empirical approach for calibration of CR-39 detectors in diffusion chambers for radon measurements

    Energy Technology Data Exchange (ETDEWEB)

    Pereyra A, P.; Lopez H, M. E. [Pontificia Universidad Catolica del Peru, Av. Universitaria 1801, San Miguel Lima 32 (Peru); Palacios F, D.; Sajo B, L. [Universidad Simon Bolivar, Laboratorio de Fisica Nuclear, Apartado 89000 Caracas (Venezuela, Bolivarian Republic of); Valdivia, P., E-mail: ppereyr@pucp.edu.pe [Universidad Nacional de Ingenieria, Av. Tupac Amaru s/n, Rimac, Lima 25 (Peru)

    2016-10-15

    Simulated and measured calibration of PADC detectors is given for cylindrical diffusion chambers employed in environmental radon measurements. The method is based on determining the minimum alpha energy (E{sub min}), average critical angle (<Θ{sub c}>), and fraction of {sup 218}Po atoms; the volume of the chamber (f{sub 1}), are compared to commercially available devices. Radon concentration for exposed detectors is obtained from induced track densities and the well-established calibration coefficient for NRPB monitor. Calibration coefficient of a PADC detector in a cylindrical diffusion chamber of any size is determined under the same chemical etching conditions and track analysis methodology. In this study the results of numerical examples and comparison between experimental calibration coefficients and simulation purpose made code. Results show that the developed method is applicable when uncertainties of 10% are acceptable. (Author)

  11. Indoor radon and radon daughters survey at Campinas-Brazil using CR-39: First results

    International Nuclear Information System (INIS)

    Guedes, S.; Hadler, J.C.N.; Iunes, P.J.; Navia, L.M.S.; Neman, R.S.; Paulo, S.R.; Rodrigues, V.C.; Souza, W.F.; Tello, C.A.S.; Zuniga, A.

    1999-01-01

    The first results of a radon and radon daughters (RD) survey performed at Campinas-SP, Brazil, are presented. We employed a technique that, potentially, makes possible to measure the radon and RD activity in the air and to separate from this result the activity of radon, alone. In this preliminary paper only the former activity is studied

  12. Indoor radon and radon daughters survey at Campinas-Brazil using CR-39: First results

    CERN Document Server

    Guedes, S; Iunes, P J; Navia, L M S; Neman, R S; Paulo, S R; Rodrigues, V C; Souza, W F; Tello, C A S; Zúñiga, A G

    1999-01-01

    The first results of a radon and radon daughters (RD) survey performed at Campinas-SP, Brazil, are presented. We employed a technique that, potentially, makes possible to measure the radon and RD activity in the air and to separate from this result the activity of radon, alone. In this preliminary paper only the former activity is studied.

  13. Investigations of doses on board commercial passenger aircraft using CR-39 and thermoluminescent detectors

    Czech Academy of Sciences Publication Activity Database

    Horwacik, T.; Bilski, P.; Olko, P.; Spurný, František; Turek, Karel

    2004-01-01

    Roč. 110, 1-4 (2004), s. 377-380 ISSN 0144-8420 Grant - others:EC project(XE) FIGM-CT2000-00068 Institutional research plan: CEZ:AV0Z1048901 Keywords : Aircrew * thermoluminescent detectors * environmental measurements Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders Impact factor: 0.617, year: 2003

  14. US progress on the development of CR-39 based neutron dosimeters

    International Nuclear Information System (INIS)

    Hadlock, D.E.

    1987-06-01

    Historically at US nuclear facilities, two types of personnel neutron dosimeters have been in routine use: nuclear track emulsion-Type A (NTA) film and thermoluminescent dosimeter (TLD)-albedo. Both of these dosimeters have energy-dependent responses. Therefore, the neutron energy spectra must be known, to interpret the dosimeter results properly. A new state-of-the-art dosimetry system has been developed within the US Department of Energy (US DOE) Personnel Neutron Dosimeter Evaluation and Upgrade Program. This system is called the combination thermoluminescent dosimeter/track etch dosimeter (TLD/TED). This paper briefly describes US DOE research currently being conducted to further enhance the TED portion of the combination TLD/TED system. The research areas involved include dose sensitivity, neutron energy range, specialized radiators, self-developing dosimeters, and neutron spectrometry. 1 fig., 1 tab

  15. Semi-empirical approach for calibration of CR-39 detectors in diffusion chambers for radon measurements

    International Nuclear Information System (INIS)

    Pereyra A, P.; Lopez H, M. E.; Palacios F, D.; Sajo B, L.; Valdivia, P.

    2016-10-01

    Simulated and measured calibration of PADC detectors is given for cylindrical diffusion chambers employed in environmental radon measurements. The method is based on determining the minimum alpha energy (E min ), average critical angle (<Θ c >), and fraction of 218 Po atoms; the volume of the chamber (f 1 ), are compared to commercially available devices. Radon concentration for exposed detectors is obtained from induced track densities and the well-established calibration coefficient for NRPB monitor. Calibration coefficient of a PADC detector in a cylindrical diffusion chamber of any size is determined under the same chemical etching conditions and track analysis methodology. In this study the results of numerical examples and comparison between experimental calibration coefficients and simulation purpose made code. Results show that the developed method is applicable when uncertainties of 10% are acceptable. (Author)

  16. Fast neutron personnel dosimetry by CR-39 plastics a new electrochemical etching procedure

    International Nuclear Information System (INIS)

    Djeffal, S.

    1984-07-01

    In the first part of this work a brief description of solid state nuclear track detectors, the principles of track registration and the different reading techniques are given. In the experimental part of the present work we systematically analysed different etching procedures and set a new electrochemical etching method, which enables us to develop a new fast neutron dosimeter. This fast neutron dosimeter makes possible the measurement of low neutron doses in the energy range from 10 Kev to 20 Mev with a reasonably flat energy response. These new developments are very attractive in personnel neutron dosimetry where nuclear emulsions are still used despite their insensitivity to neutron energies down to 500 Kev (i.e. the energy range one often encounters around nuclear facilities)

  17. Shape memory polymers

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, Thomas S.; Bearinger, Jane P.

    2017-08-29

    New shape memory polymer compositions, methods for synthesizing new shape memory polymers, and apparatus comprising an actuator and a shape memory polymer wherein the shape memory polymer comprises at least a portion of the actuator. A shape memory polymer comprising a polymer composition which physically forms a network structure wherein the polymer composition has shape-memory behavior and can be formed into a permanent primary shape, re-formed into a stable secondary shape, and controllably actuated to recover the permanent primary shape. Polymers have optimal aliphatic network structures due to minimization of dangling chains by using monomers that are symmetrical and that have matching amine and hydroxl groups providing polymers and polymer foams with clarity, tight (narrow temperature range) single transitions, and high shape recovery and recovery force that are especially useful for implanting in the human body.

  18. Shape memory polymers

    Science.gov (United States)

    Wilson, Thomas S.; Bearinger, Jane P.

    2015-06-09

    New shape memory polymer compositions, methods for synthesizing new shape memory polymers, and apparatus comprising an actuator and a shape memory polymer wherein the shape memory polymer comprises at least a portion of the actuator. A shape memory polymer comprising a polymer composition which physically forms a network structure wherein the polymer composition has shape-memory behavior and can be formed into a permanent primary shape, re-formed into a stable secondary shape, and controllably actuated to recover the permanent primary shape. Polymers have optimal aliphatic network structures due to minimization of dangling chains by using monomers that are symmetrical and that have matching amine and hydroxyl groups providing polymers and polymer foams with clarity, tight (narrow temperature range) single transitions, and high shape recovery and recovery force that are especially useful for implanting in the human body.

  19. Energetic metallic ion implantation in polymers via cost-effective laser-driven ion source

    Science.gov (United States)

    Tahir, Muhammad Bilal; Rafique, M. Shahid; Ahmed, Rabia; Rafique, M.; Iqbal, Tahir; Hasan, Ali

    2017-07-01

    This research work reports the ions emission from the plasma generated by Nd:YAG laser having wavelength 1.064 μm, power 1.1 MW, pulse energy 10 mJ and intensity 1011 W/cm2 irradiated at 70° with respect to the target normal to the ions. These ions were accelerated through a home-made extraction assembly by means of a high voltage DC power supply. The energy of these ions were measured using Thomson parabola technique which utilizes Solid State Nuclear Track Detector (CR-39) and confirmed by Faraday cup as well that exploits a well-known technique known as time of flight. Interestingly, a significant increase in energy (from 490 to 730 keV) was observed with a discrete increase in acceleration potential from 0 to 18 kV. Polyethylene terephthalate (PET) and polypropylene were exposed to this recently developed ion source facility, to authenticate the reliability of this facility. The surface of the polymer is affected when energy of the irradiated ion is increased, which is evident from the optical micrographs. An increase in electrical conductivity was also observed with the increase in ion energy.

  20. Polymer nanocomposites: polymer and particle dynamics

    KAUST Repository

    Kim, Daniel

    2012-01-01

    Polymer nanocomposites containing nanoparticles smaller than the random coil size of their host polymer chains are known to exhibit unique properties, such as lower viscosity and glass transition temperature relative to the neat polymer melt. It has been hypothesized that these unusual properties result from fast diffusion of the nanostructures in the host polymer, which facilitates polymer chain relaxation by constraint release and other processes. In this study, the effects of addition of sterically stabilized inorganic nanoparticles to entangled cis-1,4-polyisoprene and polydimethylsiloxane on the overall rheology of nanocomposites are discussed. In addition, insights about the relaxation of the host polymer chains and transport properties of nanoparticles in entangled polymer nanocomposites are presented. The nanoparticles are found to act as effective plasticizers for their entangled linear hosts, and below a critical, chemistry and molecular-weight dependent particle volume fraction, lead to reduced viscosity, glass transition temperature, number of entanglements, and polymer relaxation time. We also find that the particle motions in the polymer host are hyperdiffusive and at the nanoparticle length scale, the polymer host acts like a simple, ideal fluid and the composites\\' viscosity rises with increasing particle concentration. © 2012 The Royal Society of Chemistry.

  1. La coyuntura económica nacional

    Directory of Open Access Journals (Sweden)

    Arturo Huerta González

    2003-01-01

    Full Text Available El objetivo de este artículo es analizar los problemas de contracción económica que enfrenta nuestro país como resultado de la política económica predominante, que lo ha llevado a depender de la economía estadounidense. Cuando ésta enfrentó problemas de crecimiento también frenó el crecimiento de la economía nacional. El gobierno mexicano no instrumenta política fiscal anticíclica (expansión del gasto para contrarrestar la caída de exportaciones y recuperar la dinámica económica por considerar que ello originaría presiones sobre precios y el sector externo y pudiera llevar a un contexto de especulación y crisis. Es por esto que se opta por seguir priorizando políticas contraccionistas para evitar la inflación, como si éste fuese el principal problema del país. Asimismo, el gobierno insiste en las reformas estructurales (apertura eléctrica, petrolera, reforma fiscal y laboral para ampliar la esfera de influencia del sector privado nacional y extranjero y para consolidar el saneamiento fiscal y abaratar el costo de la fuerza de trabajo, impulsando así la dinámica económica. Sin embargo, tales reformas ya las hemos vivido —desde el gobierno de Salinas de Gortari a la fecha— y sus resultados han sido crecimientos espurios que han desembocado en crisis y en el actual estancamiento. Mientras prosiga la actual política económica seguirá deteriorándose la esfera productiva y aumentando el desempleo, sin que se logre un crecimiento sostenido y menos vulnerable de la economía

  2. QUÍMICA VERDE: UN NUEVO RETO

    Directory of Open Access Journals (Sweden)

    Nerlis Paola Pájaro Castro

    2011-01-01

    Full Text Available En la actualidad, existe un enorme deterioro del medio ambiente que ha generado la necesidad de buscar alternativas que conduzcan a la sostenibilidad ambiental. Una de estas herramientas es la ¿química verde¿, concepto que contempla el diseño de productos y procesos que reduzcan la generación de sustancias peligrosas y maximicen la eficiencia en la utilización de recursos materiales y energéticos. El empleo de tecnologías menos contaminantes, permitirá a las empresas químicas mitigar los efectos ambientales asociados a su actividad, reduciendo el consumo de materiales e incrementando la participación de recursos renovables. Para alcanzar estas metas, se han propuesto 12 principios básicos de química verde, aplicables en diferentes campos, tales como la medicina, la agricultura, la industria química y farmacéutica. Esta revisión detalla los principios y usos principales de la química verde, y su aplicación como una filosofía de trabajo para avanzar hacia un verdadero desarrollo sostenible.

  3. Microgel polymer composite fibres

    OpenAIRE

    Kehren, Dominic

    2014-01-01

    In this thesis some novel ideas and advancements in the field of polymer composite fibres, specifically microgel-based polymer composite fibres have been achieved. The main task was to investigate and understand the electrospinning process of microgels and polymers and the interplay of parameter influences, in order to fabricate reproducible and continuously homogenous composite fibres. The main aim was to fabricate a composite material which combines the special properties of polymer fibres ...

  4. Thermosetting Phthalocyanine Polymers

    Science.gov (United States)

    Fohlen, G.; Parker, J.; Achar, B.

    1985-01-01

    Group of phthalocyanine polymers resist thermal degradation. Polymers expected semiconducting. Principal applications probably in molded or laminated parts that have to withstand high temperatures. Polymers made from either of two classes of monomer: Bisphthalonitriles with imide linkages or Bisphthalonitriles with ester-imide linkages.

  5. based gel polymer electrolytes

    Indian Academy of Sciences (India)

    (PVdF) as a host polymer, lithium perchlorate (LiClO4), lithium triflate ... TG/DTA studies showed the thermal stability of the polymer electrolytes. .... are observed while comparing pure XRD spectra with .... batteries as its operating temperature is normally in the .... chain ion movements and the conductivity of the polymer.

  6. Aerogel / Polymer Composite Materials

    Science.gov (United States)

    Williams, Martha K. (Inventor); Smith, Trent M. (Inventor); Fesmire, James E. (Inventor); Roberson, Luke B. (Inventor); Clayton, LaNetra M. (Inventor)

    2017-01-01

    The invention provides new composite materials containing aerogels blended with thermoplastic polymer materials at a weight ratio of aerogel to thermoplastic polymer of less than 20:100. The composite materials have improved thermal insulation ability. The composite materials also have better flexibility and less brittleness at low temperatures than the parent thermoplastic polymer materials.

  7. Diagenetic replacement of Micas by Carbonates

    NARCIS (Netherlands)

    Oele, E.

    1961-01-01

    In the Ordovician sandstones of the Cantabrian Mountains a replacement of the micas by carbonate minerals could be observed. The absence of metamorphic minerals suggests a diagenetic replacement. This is supported by the finding of the same type of replacement in some undisturbed Pliocene sediments

  8. MeV fullerene impacts on mica

    Energy Technology Data Exchange (ETDEWEB)

    Doebeli, M.; Scandella, L. [Paul Scherrer Inst. (PSI), Villigen (Switzerland); Ames, F. [Eidgenoessische Technische Hochschule, Zurich (Switzerland)

    1997-09-01

    Hillock heights on mica irradiated with MeV C{sub 60} ions have been investigated systematically. Results show that the small range of secondary particles along the track plays a crucial role in defect production. (author) figs., tab., refs.

  9. APRENDIENDO ELECTROQUÍMICA. UN ESTUDIO COMPARATIVO

    Directory of Open Access Journals (Sweden)

    Maria I. Vera

    2011-01-01

    Full Text Available Se realizó un seguimiento del proceso de enseñanza y aprendizaje de Electroquímica y se compararon los resultados obtenidos en evaluaciones parciales, con el objetivo de analizar si existen diferencias significativas en la apropiación de contenidos entre alumnos de carreras con diferentes perfiles. Se trabajó en los años 2009 y 2010 con dos grupos de alumnos en cada año, pertenecientes a carreras químicas y no químicas respectivamente. En ambos grupos se desarrollaron, con la misma carga horaria, contenidos conceptuales y procedimentales en clases teóricas con prácticas de resolución de problemas y de laboratorio. Para la evaluación se presentaron idénticas situaciones problemáticas, cuyos resultados muestran diferencias no significativas entre ambos grupos en la identificación del cátodo y del ánodo y cálculo de la fem estándar de la celda; en cambio en la aplicación de la Ecuación de Nernst y la identificación de especies químicas que reaccionan en los electrodos, hay diferencias significativas en las respuestas dadas.

  10. mica – music information center austria

    OpenAIRE

    2010-01-01

    1994 wurde das österreichische Musikinformationszentrum (mica) im Auftrag des österreichischen Bundesministers für Unterricht und Kunst (Rudolf Scholten) von den Bundeskuratoren für Musik (L. Knessl, Christian Scheib) gegründet (Geschäftsführer 1994–99 Matthias Finkentey, 1999–09 Peter Rantasa, ab 2009 Sabine Reiter).

  11. Electroluminescence of Multicomponent Conjugated Polymers. 1. Roles of Polymer/Polymer Interfaces in Emission Enhancement and Voltage-Tunable Multicolor Emission in Semiconducting Polymer/Polymer Heterojunctions

    National Research Council Canada - National Science Library

    Zhang, Xuejun, Ph.D

    1999-01-01

    Effects of the electronic structure of polymer/polymer interfaces on the electroluminescence efficiency and tunable multicolor emission of polymer heterojunction light-emitting diodes were explored...

  12. Atomically flat platinum films grown on synthetic mica

    Science.gov (United States)

    Tanaka, Hiroyuki; Taniguchi, Masateru

    2018-04-01

    Atomically flat platinum thin films were heteroepitaxially grown on synthetic fluorophlogopite mica [KMg3(AlSi3O10)F2] by van der Waals epitaxy. Platinum films deposited on a fluorophlogopite mica substrate by inductively coupled plasma-assisted sputtering with oxygen introduction on a synthetic mica substrate resulted in the growth of twin single-crystalline epitaxial Pt(111) films.

  13. Nanoporous polymer electrolyte

    Science.gov (United States)

    Elliott, Brian [Wheat Ridge, CO; Nguyen, Vinh [Wheat Ridge, CO

    2012-04-24

    A nanoporous polymer electrolyte and methods for making the polymer electrolyte are disclosed. The polymer electrolyte comprises a crosslinked self-assembly of a polymerizable salt surfactant, wherein the crosslinked self-assembly includes nanopores and wherein the crosslinked self-assembly has a conductivity of at least 1.0.times.10.sup.-6 S/cm at 25.degree. C. The method of making a polymer electrolyte comprises providing a polymerizable salt surfactant. The method further comprises crosslinking the polymerizable salt surfactant to form a nanoporous polymer electrolyte.

  14. Polymer friction Molecular Dynamics

    DEFF Research Database (Denmark)

    Sivebæk, Ion Marius; Samoilov, Vladimir N.; Persson, Bo N. J.

    We present molecular dynamics friction calculations for confined hydrocarbon solids with molecular lengths from 20 to 1400 carbon atoms. Two cases are considered: a) polymer sliding against a hard substrate, and b) polymer sliding on polymer. In the first setup the shear stresses are relatively...... independent of molecular length. For polymer sliding on polymer the friction is significantly larger, and dependent on the molecular chain length. In both cases, the shear stresses are proportional to the squeezing pressure and finite at zero load, indicating an adhesional contribution to the friction force....

  15. Biostable glucose permeable polymer

    DEFF Research Database (Denmark)

    2017-01-01

    A new biostable glucose permeable polymer has been developed which is useful, for example, in implantable glucose sensors. This biostable glucose permeable polymer has a number of advantageous characteristics and, for example, does not undergo hydrolytic cleavage and degradation, thereby providing...... a composition that facilitates long term sensor stability in vivo. The versatile characteristics of this polymer allow it to be used in a variety of contexts, for example to form the body of an implantable glucose sensor. The invention includes the polymer composition, sensor systems formed from this polymer...

  16. Fluorination of polymers

    International Nuclear Information System (INIS)

    Du Toit, F.J.

    1991-01-01

    Polyethylene and polypropylene were reacted with elemental fluorine under carefully controlled conditions to produce fluorocarbon polymers. Fluorination of polymer films resulted in fluorination of only the outer surfaces of the films, while the reaction of elemental fluorine with powdered hydrocarbon polymers produced perfluorocarbon polymers. Existing and newly developed techniques were used to characterize the fluorinated polymers. It was shown that the degree of fluorination was influenced by the surface area of the hydrocarbon material, the concentration, of the fluorine gas, and the time and temperature of fluorination. A fluidized-bed reactor used for the fluorination of polymer powders effectively increased the reaction rate. The surface tension and the oxygen permeability of the fluorinated polymers were studied. The surface tension of hydrocarbon polymers was not influenced by different solvents, but the surface tension of fluorinated polymers was affected by the type of solvent that was used. There were indications that the surface tension was affected by oxygen introduced into the polymer surface during fluorination. Fluorination lowered the permeability of oxygen through hydrocarbon polymers. 55 refs., 51 figs., 26 tabs

  17. Advanced polymers in medicine

    CERN Document Server

    Puoci, Francesco

    2014-01-01

    The book provides an up-to-date overview of the diverse medical applications of advanced polymers. The book opens by presenting important background information on polymer chemistry and physicochemical characterization of polymers. This serves as essential scientific support for the subsequent chapters, each of which is devoted to the applications of polymers in a particular medical specialty. The coverage is broad, encompassing orthopedics, ophthalmology, tissue engineering, surgery, dentistry, oncology, drug delivery, nephrology, wound dressing and healing, and cardiology. The development of polymers that enhance the biocompatibility of blood-contacting medical devices and the incorporation of polymers within biosensors are also addressed. This book is an excellent guide to the recent advances in polymeric biomaterials and bridges the gap between the research literature and standard textbooks on the applications of polymers in medicine.

  18. Antiviral Polymer Therapeutics

    DEFF Research Database (Denmark)

    Smith, Anton Allen Abbotsford

    2014-01-01

    polymerized in a controlled manner with carrier monomers of historically proven biocompatible polymers. The carrier polymers, the loading of ribavirin as well as the size of the polymer were varied systematically with the aid of an automated synthesis platform. These polymers were tested in a cellular assay...... of reversible-addition-fragmentation chain transfer polymerization, which not only controls the size of polymer, but also allows the introduction of a terminal amine on the polymer which can be used for further conjugation. This has allowed for not only fluorescent labeling of the polymer, but also protein...... is mediated through specific transporters, it is thought that the accumulation can be alleviated through the attachment of ribavirin to a macromolecule. To this end, ribavirin was enzymatically modified into a monomer compatible with controlled polymerization techniques. The ribavirin monomers were...

  19. Polymer reaction engineering, an integrated approach

    NARCIS (Netherlands)

    Meyer, T.; Keurentjes, J.T.F.; Meyer, T.; Keurentjes, J.T.F.

    2005-01-01

    Summary This chapter contains sections titled: Polymer Materials A Short History of Polymer Reaction Engineering The Position of Polymer Reaction Engineering Toward Integrated Polymer Reaction Engineering The Disciplines in Polymer Reaction Engineering The Future: Product-inspired Polymer Reaction

  20. Star-Branched Polymers (Star Polymers)

    KAUST Repository

    Hirao, Akira; Hayashi, Mayumi; Ito, Shotaro; Goseki, Raita; Higashihara, Tomoya; Hadjichristidis, Nikolaos

    2015-01-01

    The synthesis of well-defined regular and asymmetric mixed arm (hereinafter miktoarm) star-branched polymers by the living anionic polymerization is reviewed in this chapter. In particular, much attention is being devoted to the synthetic

  1. Polymer dynamics from synthetic polymers to proteins

    Indian Academy of Sciences (India)

    Abstract. Starting from the standard model of polymer motion – the Rouse model – .... reptation and the escape processes (creep motion) from the tube. .... scattering curves from an arrangement of small mesoscopic spheres also allows a.

  2. Star-Branched Polymers (Star Polymers)

    KAUST Repository

    Hirao, Akira

    2015-09-01

    The synthesis of well-defined regular and asymmetric mixed arm (hereinafter miktoarm) star-branched polymers by the living anionic polymerization is reviewed in this chapter. In particular, much attention is being devoted to the synthetic development of miktoarm star polymers since 2000. At the present time, the almost all types of multiarmed and multicomponent miktoarm star polymers have become feasible by using recently developed iterative strategy. For example, the following well-defined stars have been successfully synthesized: 3-arm ABC, 4-arm ABCD, 5-arm ABCDE, 6-arm ABCDEF, 7-arm ABCDEFG, 6-arm ABC, 9-arm ABC, 12-arm ABC, 13-arm ABCD, 9-arm AB, 17-arm AB, 33-arm AB, 7-arm ABC, 15-arm ABCD, and 31-arm ABCDE miktoarm star polymers, most of which are quite new and difficult to synthesize by the end of the 1990s. Several new specialty functional star polymers composed of vinyl polymer segments and rigid rodlike poly(acetylene) arms, helical polypeptide, or helical poly(hexyl isocyanate) arms are introduced.

  3. Computadores y democracia económica

    Directory of Open Access Journals (Sweden)

    Allin Cottrell

    2008-12-01

    Full Text Available El colapso del socialismo anteriormente existente obedeció a causas integradas en su mecanismo económico, que no son inherentes a todos los socialismos posibles. El artículo muestra que la teoría económica marxista, junto con la informática, proporciona el fundamento para adelantar un programa económico socialista viable y que el desarrollo de la informática y de Internet hace posible la planificación económica. Además, argumenta que el movimiento socialista nunca desarrolló un programa constitucional correcto y que la tecnología moderna abre nuevas oportunidades para la democracia. Por último, revisa los argumentos austriacos contra la posibilidad del cálculo socialista a la luz de la nueva capacidad informática y de las limitaciones del Protocolo de Kyoto.

  4. Farmacogenómica: Aplicaciones cardiovasculares

    Directory of Open Access Journals (Sweden)

    Luis Quiñones S., PH.D.

    2015-03-01

    Este trabajo pretende dar una visión general acerca de farmacogenómica cardiovascular y la posibilidad de utilizar, en la consulta clínica, herramientas genéticas para apoyar la decisión farmacoterapéutica, con el objeto de mejorar la respuesta al tratamiento de enfermedades cardiovasculares, un paso hacia la medicina personalizada en Chile.

  5. Artificially Engineered Protein Polymers.

    Science.gov (United States)

    Yang, Yun Jung; Holmberg, Angela L; Olsen, Bradley D

    2017-06-07

    Modern polymer science increasingly requires precise control over macromolecular structure and properties for engineering advanced materials and biomedical systems. The application of biological processes to design and synthesize artificial protein polymers offers a means for furthering macromolecular tunability, enabling polymers with dispersities of ∼1.0 and monomer-level sequence control. Taking inspiration from materials evolved in nature, scientists have created modular building blocks with simplified monomer sequences that replicate the function of natural systems. The corresponding protein engineering toolbox has enabled the systematic development of complex functional polymeric materials across areas as diverse as adhesives, responsive polymers, and medical materials. This review discusses the natural proteins that have inspired the development of key building blocks for protein polymer engineering and the function of these elements in material design. The prospects and progress for scalable commercialization of protein polymers are reviewed, discussing both technology needs and opportunities.

  6. Internally plasticised cellulose polymers

    International Nuclear Information System (INIS)

    Burnup, M.; Hayes, G.F.; Fydelor, P.J.

    1981-01-01

    Plasticised cellulose polymers comprise base polymer having a chain of β-anhydroglucose units joined by ether linkages, with at least one of said units carrying at least one chemically unreactive side chain derived from an allylic monomer or a vinyl substituted derivative of ferrocene. The side chains are normally formed by radiation grafting. These internally plasticised celluloses are useful in particular as inhibitor coatings for rocket motor propellants and in general wherever cellulose polymers are employed. (author)

  7. Characterisation of polymers, 1

    CERN Document Server

    Crompton, Roy

    2008-01-01

    This essential guide to Polymer Characterisation is a complete compendium of methodologies that have evolved for the determination of the chemical composition of polymers. This 478-page book gives an up-to-date and thorough exposition of the state-of-the-art theories and availability of instrumentation needed to effect chemical and physical analysis of polymers. This is supported by approximately 1200 references. Volume 1 covers the methodology used for the determination of metals, non-metals and organic functional groups in polymers, and for the determination of the ratio in which different m

  8. Poly(styrene-co-butadiene) random copolymer thin films and nanostructures on a mica surface: morphology and contact angles of nanodroplets.

    Science.gov (United States)

    McClements, Jake; Buffone, Cosimo; Shaver, Michael P; Sefiane, Khellil; Koutsos, Vasileios

    2017-09-20

    The self-assembly of poly(styrene-co-butadiene) random copolymers on mica surfaces was studied by varying solution concentrations and polymer molecular weights. Toluene solutions of the poly(styrene-co-butadiene) samples were spin coated onto a mica surface and the resulting polymer morphology was investigated by atomic force microscopy. At higher concentrations, thin films formed with varying thicknesses; some dewetting was observed which depended on the molecular weight. Total dewetting did not occur despite the polymer's low glass transition temperature. Instead, partial dewetting was observed suggesting that the polymer was in a metastable equilibrium state. At lower concentrations, spherical cap shaped nanodroplets formed with varying sizes from single polymer chains to aggregates containing millions of chains. As the molecular weight was increased, fewer aggregates were observed on the surface, albeit with larger sizes resulting from increased solution viscosities and more chain entanglements at higher molecular weights. The contact angles of the nanodroplets were shown to be size dependent. A minimum contact angle occurs for droplets with radii of 100-250 nm at each molecular weight. Droplets smaller than 100 nm showed a sharp increase in contact angle; attributed to an increase in the elastic modulus of the droplets, in addition, to a positive line tension value. Droplets larger than 250 nm also showed an increased contact angle due to surface heterogeneities which cannot be avoided for larger droplets. This increase in contact angle plateaus as the droplet size reaches the macroscopic scale.

  9. Binary Polymer Brushes of Strongly Immiscible Polymers.

    Science.gov (United States)

    Chu, Elza; Babar, Tashnia; Bruist, Michael F; Sidorenko, Alexander

    2015-06-17

    The phenomenon of microphase separation is an example of self-assembly in soft matter and has been observed in block copolymers (BCPs) and similar materials (i.e., supramolecular assemblies (SMAs) and homo/block copolymer blends (HBCs)). In this study, we use microphase separation to construct responsive polymer brushes that collapse to generate periodic surfaces. This is achieved by a chemical reaction between the minor block (10%, poly(4-vinylpyridine)) of the block copolymer and a substrate. The major block of polystyrene (PS) forms mosaic-like arrays of grafted patches that are 10-20 nm in size. Depending on the nature of the assembly (SMA, HBC, or neat BCP) and annealing method (exposure to vapors of different solvents or heating above the glass transition temperature), a range of "mosaic" brushes with different parameters can be obtained. Successive grafting of a secondary polymer (polyacrylamide, PAAm) results in the fabrication of binary polymer brushes (BPBs). Upon being exposed to specific selective solvents, BPBs may adopt different conformations. The surface tension and adhesion of the binary brush are governed by the polymer occupying the top stratum. The "mosaic" brush approach allows for a combination of strongly immiscible polymers in one brush. This facilitates substantial contrast in the surface properties upon switching, previously only possible for substrates composed of predetermined nanostructures. We also demonstrate a possible application of such PS/PAAm brushes in a tunable bioadhesion-bioadhesive (PS on top) or nonbioadhesive (PAAm on top) surface as revealed by Escherichia coli bacterial seeding.

  10. MICA: The Meta-Institute for Computational Astrophysics

    Science.gov (United States)

    McMillan, Stephen L. W.; Djorgovski, S. G.; Hut, P.; Vesperini, E.; Knop, R.; Portegies Zwart, S.

    2009-05-01

    We describe MICA, the Meta Institute for Computational Astrophysics, the first professional scientific and educational, non-profit organization based in virtual worlds [VWs]. Most MICA activities are currently conducted in Second Life, arguably the most popular and best developed VW; we plan to expand our presence into other VWs as those venues evolve. The goals of MICA include (1) exploration, development and promotion of VWs and virtual reality [VR] technologies for professional research in astronomy and related fields; (2) development of novel networking venues and mechanisms for virtual scientific communication and interaction, including professional meetings, visualization, and telecollaboration; (3) use of VWs and VR technologies for education and public outreach; and (4) exchange of ideas and joint efforts with other scientific disciplines in promoting these goals for science and scholarship in general. We present representative example of MICA activities and achievements, and outline plans for expansion of the organization. For more information on MICA, please visit http://mica-vw.org .

  11. Polymer gels and networks

    National Research Council Canada - National Science Library

    Osada, Yoshihito; Khokhlov, A. R

    2002-01-01

    ... or magnetic field, etc.). It was realized that not only can polymer gels absorb and hold a considerable volume of liquids, but they can also be forced to expel the absorbed liquid in a controlled manner. Of particular interest are hydrogels, i.e., polymer gels, which swell extensively in water. The most common hydrogels are polyelectrolyte gels: ...

  12. SANS studies of polymers

    International Nuclear Information System (INIS)

    Wignall, G.D.

    1985-01-01

    Some information provided by the application of small-angle neutron scattering concerning polymer structure is reviewed herein. Information about the polymer structure as examined in H 2 O/D 2 O mixtures is also provided. Examples of results of experiments performed at the National Center for Small-Angle Scattering Research are included

  13. Polymer based tunneling sensor

    Science.gov (United States)

    Cui, Tianhong (Inventor); Wang, Jing (Inventor); Zhao, Yongjun (Inventor)

    2006-01-01

    A process for fabricating a polymer based circuit by the following steps. A mold of a design is formed through a lithography process. The design is transferred to a polymer substrate through a hot embossing process. A metal layer is then deposited over at least part of said design and at least one electrical lead is connected to said metal layer.

  14. Polymers for Combating Biocorrosion

    Directory of Open Access Journals (Sweden)

    Jing Guo

    2018-03-01

    Full Text Available Biocorrosion has been considered as big trouble in many industries and marine environments due to causing of great economic loss. The main disadvantages of present approaches to prevent corrosion include being limited by environmental factors, being expensive, inapplicable to field, and sometimes inefficient. Studies show that polymer coatings with anticorrosion and antimicrobial properties have been widely accepted as a novel and effective approach to prevent biocorrosion. The main purpose of this review is to summarize up the progressive status of polymer coatings used for combating microbial corrosion. Polymers used to synthesize protective coatings are generally divided into three categories: (i traditional polymers incorporated with biocides, (ii antibacterial polymers containing quaternary ammonium compounds, and (iii conductive polymers. The strategies to synthesize polymer coatings resort mainly to grafting antibacterial polymers from the metal substrate surface using novel surface-functionalization approaches, such as free radical polymerization, chemically oxidative polymerization, and surface-initiated atom transfer radical polymerization, as opposed to the traditional approaches of dip coating or spin coating.

  15. Polymer light emitting diodes

    International Nuclear Information System (INIS)

    Gautier-Thianche, Emmmanuelle

    1998-01-01

    We study sandwich type semiconducting polymer light emitting diodes; anode/polymer/cathode. ITO is selected as anode, this polymer is a blend of a commercially available polymer with a high hole transport ability: polyvinyl-carbazole and a laser dye: coumarin-515. Magnesium covered with silver is chosen for the anode. We study the influence of polymer thickness and coumarin doping ratio on electroluminescence spectrum, electric characteristics and quantum efficiency. An important drawback is that diodes lifetime remains low. In the second part of our study we determine degradations causes with X-Ray reflectivity experiments. It may be due to ITO very high roughness. We realize a new type of planar electroluminescent device: a channel type electroluminescent device in which polymer layer is inserted into an aluminium channel. Such a device is by far more stable than using classical sandwich structures with the same polymer composition: indeed, charges are generated by internal-field ionization and there is no injection from the electrode to the polymer. This avoids electrochemical reactions at electrodes, thus reducing degradations routes. (author) [fr

  16. Polymers targeting habitual diseases

    Science.gov (United States)

    The use of polymeric drug conjugates mainly for the treatment for cancer therapy has been addressed, but these polymers also find their way in treatment of various lifestyle disorders like diabetes, hypertension, cardiovascular diseases etc. The focus is being laid to develop biodegradable polymer ...

  17. Stiff quantum polymers

    OpenAIRE

    Kleinert, H.

    2009-01-01

    At ultralow temperatures, polymers exhibit quantum behavior, which is calculated here for the second and fourth moments of the end-to-end distribution in the large-stiffness regime. The result should be measurable for polymers in wide optical traps.

  18. Conducting polymer hydrogels

    Czech Academy of Sciences Publication Activity Database

    Stejskal, Jaroslav

    2017-01-01

    Roč. 71, č. 2 (2017), s. 269-291 ISSN 0366-6352 R&D Projects: GA ČR(CZ) GA16-02787S Institutional support: RVO:61389013 Keywords : aerogel * conducting polymers * conductivity Subject RIV: CD - Macromolecular Chemistry OBOR OECD: Polymer science Impact factor: 1.258, year: 2016

  19. Theory of polymer blends

    International Nuclear Information System (INIS)

    Curro, J.G.; Schweizer, K.S.

    1989-01-01

    We have recently developed a new theoretical approach to the study of polymer liquids. The theory is based on the ''reference interaction site model'' (RISM theory) of Chandler and Andersen, which has been successful in describing the structure of small molecule liquids. We have recently extended our polymer RISM theory to the case of polymer blends. In the present investigation we have applied this theory to two special binary blends: (1) the athermal mixture where we isolate structural effects, and (2) the isotopic mixture in which structurally identical polymer chains interact with dissimilar attractive interactions. By studying these two special cases we are able to obtain insights into the molecular factors which control the miscibility in polymer mixtures. 18 refs., 2 figs

  20. Ion Implantation of Polymers

    DEFF Research Database (Denmark)

    Popok, Vladimir

    2012-01-01

    The current paper presents a state-of-the-art review in the field of ion implantation of polymers. Numerous published studies of polymers modified by ion beams are analysed. General aspects of ion stopping, latent track formation and changes of structure and composition of organic materials...... are discussed. Related to that, the effects of radiothermolysis, degassing and carbonisation are considered. Specificity of depth distributions of implanted into polymers impurities is analysed and the case of high-fluence implantation is emphasised. Within rather broad topic of ion bombardment, the focus...... is put on the low-energy implantation of metal ions causing the nucleation and growth of nanoparticles in the shallow polymer layers. Electrical, optical and magnetic properties of metal/polymer composites are under the discussion and the approaches towards practical applications are overviewed....

  1. All Polymer Micropump

    DEFF Research Database (Denmark)

    Hansen, Thomas Steen

    2008-01-01

    In this thesis an all polymer micropump, and the fabrication method required to fabricate this, are examined. Polymer microfluidic. devices are of major scientific interest because they can combine complicated chemical and biological analys~s in cheap and disposable devices. The electrode system...... in the micropump is based on the conducting polymer poly(3,4 ethylenedioxythiophene) (PEDOT). The majority of the work conducted was therefore aimed at developing methods for patterning and processing PEDOT. First a method was developed, where the conducting polymer PEDOT can be integrated into non...... of the substrate, the PEDOT is integrated into the non-conductive polymer. The result is a material that retains the good conductivity of PEDOT, but gains the mechanical stability of the substrate. The best results were obtained for PEDOTjPMMA. The new mechanically stable PEDOTjPMMA was micro-patterned using clean...

  2. Polymer wear evaluation

    DEFF Research Database (Denmark)

    Lagerbon, Mikkel; Sivebæk, Ion Marius

    2012-01-01

    Polymer wear plays an increasing role in manufacturing of machine parts for e.g. medical devices. Some of these have an expected lifetime of five to eight years during which very little wear of the components is acceptable. Too much wear compromises the dosage accuracy of the device and thereby...... the safety of the patients. Prediction of the wear of polymers is complicated by the low thermal conductivity of this kind of material. It implies that any acceleration of testing conditions by increased contact pressure and/or sliding velocity will make the polymer fail due to exaggerated heat buildup....... This is not the kind of wear observed in medical devices. In the present work a method was developed capable of evaluating the wear progression in polymer-polymer contacts. The configuration of the setup is injection moulded specimens consisting of an upper part having a toroid shape and a lower flat part. The sliding...

  3. La polémica del nacionalismo

    Directory of Open Access Journals (Sweden)

    Germán Posada

    1961-10-01

    Full Text Available La polémica empezó con el artículo de Hernando Téllez, hace veinte días. Con el pretexto de defender a los escritores de su propia generación, a quienes, según él, se viene acusando sistemáticamente de producir una literatura desarraigada y ausente de la vida nacional, Téllez se lanzó a combatir las teorías de " nacionalismo literario'' que actualmente se agitan en Colombia.

  4. La farmacogenómica en medicina

    OpenAIRE

    Carlos Isaza; Juan C. Sepúlveda-Arias; Julieta Henao

    2009-01-01

    Introducción: La farmacogenómica estudia la forma como las variaciones del genoma influyen en la respuesta a medicamentos. Su principal valor médico consiste en: i) la identificación de individuos en quienes se puede predecir si un fármaco será eficaz y a qué dosis o, por el contrario, si el fármaco se debe evitar por alto riesgo de toxicidad o porque el paciente nunca responderá a él; ii) identificar blancos moleculares susceptibles de ser intervenidos por fármacos.Objetivo: Revisar y sistem...

  5. Química de Heterociclos

    OpenAIRE

    Collado, Daniel

    2014-01-01

    Heterociclos aromáticos con cinco miembros. Pirrol, furano y tiofeno: propiedades. Sustitución electrofílica aromática. Reacciones de los sustituyentes alquílicos. Sustitución nucleofílica. Radicales y carbenos, aperturas de anillo. Síntesis. Capítulo segundo del temario del segundo bloque de la asignatura Ampliación de Química Orgánica Avanzada. Heterociclos aromáticos de cinco miembros.

  6. Filogenómica y genómica de la adaptación

    OpenAIRE

    Zardoya, Rafael; Sánchez-Gracia, Alejandro; Rozas Liras, Julio A.

    2017-01-01

    La posibilidad técnica actual de secuenciar genomas y transcriptomas completos de cualquier especie abre la puerta a cumplir la predicción de Darwin de poder reconstruir de forma rigurosa el árbol de la vida (las relaciones filogenéticas de todos los seres vivos actuales) mediante la filogenómica.

  7. Paragenesis of Cr-rich muscovite and chlorite in green-mica ...

    Indian Academy of Sciences (India)

    peculiar green colour is attributed to the concen- tration of .... mica quartzite, 1g: white mica (paucity of green mica) with ..... lacking in the white micas. 6.2 Chlorites. Chlorites are associated with green micas in the. Palasgaon–Saigaon area. EPMA analysis of the representative chlorites has been obtained. Cations.

  8. Photoluminescence in conjugated polymers

    International Nuclear Information System (INIS)

    Furst, J.E.; Laugesen, R.; Dastoor, P.; McNeill, C.

    2002-01-01

    Full text: Conjugated polymers combine the electronic and optical properties of semiconductors with the processability of polymers. They contain a sequence of alternate single and double carbon bonds so that the overlap of unhybridised p z orbitals creates a delocalised ρ system which gives semiconducting properties with p-bonding (valence) and p* -antibonding (conduction) bands. Photoluminesence (PL) in conjugated polymers results from the radiative decay of singlet excitons confined to a single chain. The present work is the first in a series of studies in our laboratory that will characterize the optical properties of conjugated polymers. The experiment involves the illumination of thin films of conjugated polymer with UV light (I=360 nm) and observing the subsequent fluorescence using a custom-built, fluorescence spectrometer. Photoluminesence spectra provide basic information about the structure of the polymer film. A typical spectrum is shown in the accompanying figure. The position of the first peak is related to the polymer chain length and resolved multiple vibronic peaks are an indication of film structure and morphology. We will also present results related to the optical degradation of these materials when exposed to air and UV light

  9. Molecular beam epitaxy of graphene on mica

    International Nuclear Information System (INIS)

    Lippert, G.; Dabrowski, J.; Yamamoto, Y.; Mehr, W.; Lupina, G.; Herziger, F.; Maultzsch, J.; Baringhaus, J.; Tegenkamp, C.; Lemme, M.C.

    2012-01-01

    Realization of graphene devices is often hindered by the fact that the known layer growth methods do not meet the requirements of the device fabrication in silicon mainstream technology. For example, the relatively straightforward method of decomposition of hexagonal SiC is not CMOS-compatible due to the high-thermal budget it requires [Moon et al., IEEE Electron Device Lett. 31, 260 (2010)]. Techniques based on layer transfer are restricted because of the uncertainty of residual metal contaminants, particles, and structural defects. Of interest is thus a method that would allow one to grow a graphene film directly in the device area where graphene is needed. Production of large area graphene is not necessarily required in this case, but high quality of the film and metal-free growth on an insulating substrate at temperatures below 1000 C are important requirements. We demonstrate direct growth of defect-free graphene on insulators at moderate temperatures by molecular beam epitaxy. The quality of the graphene was probed by high-resolution Raman spectroscopy, indicating a negligible density of defects. The spectra are compared with those from graphene flakes mechanically exfoliated from native graphite onto mica. These results are combined with insights from density functional theory calculations. A model of graphene growth on mica and similar substrates is proposed. (Copyright copyright 2012 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  10. Aprendiendo química con golosinas

    Directory of Open Access Journals (Sweden)

    José Manuel Rodríguez Rodríguez

    2011-01-01

    Full Text Available Las golosinas (caramelos, chicles, nubes, palotes, papas fritas, etc. nos gustan a casi todos y gozan de una imagen positiva, a pesar de sus efectos secundarios si no se consumen con moderación. Aprovechándonos de esa buena imagen y de la gran variedad de golosinas que existen en el mercado, hemos diseñado una serie de experimentos con los que podemos explicar distintos tipos de reacciones químicas (ácido-base, oxidación reducción, endotérmicas¿, la actuación de un indicador e, incluso, podemos comparar cantidades de vitamina C. En todas las actividades se persigue explicar algún aspecto de la Química que, en general, el público desconoce, captando su atención, por ejemplo, mediante cambios de color espectaculares y con las golosinas como protagonistas. Así mismo, estas experiencias pueden emplearse como recursos didácticos para alumnos de 4º E.S.O. y Bachillerato, apoyando los contenidos teóricos del currículum.

  11. Biomedical applications of polymers

    CERN Document Server

    Gebelein, C G

    1991-01-01

    The biomedical applications of polymers span an extremely wide spectrum of uses, including artificial organs, skin and soft tissue replacements, orthopaedic applications, dental applications, and controlled release of medications. No single, short review can possibly cover all these items in detail, and dozens of books andhundreds of reviews exist on biomedical polymers. Only a few relatively recent examples will be cited here;additional reviews are listed under most of the major topics in this book. We will consider each of the majorclassifications of biomedical polymers to some extent, inclu

  12. SANS studies of polymers

    International Nuclear Information System (INIS)

    Wignall, G.D.

    1984-10-01

    Before small-angle neutron scattering (SANS), chain conformation studies were limited to light and small angle x-ray scattering techniques, usually in dilute solution. SANS from blends of normal and labeled molecules could give direct information on chain conformation in bulk polymers. Water-soluble polymers may be examined in H 2 O/D 2 O mixtures using contrast variation methods to provide further information on polymer structure. This paper reviews some of the information provided by this technique using examples of experiments performed at the National Center for Small-Angle Scattering Research (NCSASR)

  13. Development of Silicate Polymers

    DEFF Research Database (Denmark)

    Søgaard, Erik Gydesen; Simonsen, Morten Enggrob

      The development of inorganic polymers is a new promising technology that may be used in many applications. The syntheses of inorganic polymers are normally carried out either by mixing an amorphous material for example silicium dioxide with a mineral base or dissolving metal oxids or metal...... hydroxide in acid and increase pH to saturation of the metal hydroxide. It is assumed that the syntheses of the inorganic polymer are carried out through polymerisation of oligomers (dimer, trimer) which provide the actual unit structures of the three dimensional macromolecular structure. In this work...

  14. Soluble porphyrin polymers

    Science.gov (United States)

    Gust, Jr., John Devens; Liddell, Paul Anthony

    2015-07-07

    Porphyrin polymers of Structure 1, where n is an integer (e.g., 1, 2, 3, 4, 5, or greater) ##STR00001## are synthesized by the method shown in FIGS. 2A and 2B. The porphyrin polymers of Structure 1 are soluble in organic solvents such as 2-MeTHF and the like, and can be synthesized in bulk (i.e., in processes other than electropolymerization). These porphyrin polymers have long excited state lifetimes, making the material suitable as an organic semiconductor for organic electronic devices including transistors and memories, as well as solar cells, sensors, light-emitting devices, and other opto-electronic devices.

  15. Statistical properties of curved polymer

    Indian Academy of Sciences (India)

    respective ground states decide the conformational statistics of the polymer. For semiflexible polymers, the relevant non-dimensional quantity is lp/L, where lp is the persistence length (which is proportional to the bending modulus k) and L is the contour length of the polymer. In the limit, lp/L ≪ 1, the polymer behaves as.

  16. Graphene Visualizes the Ion Distribution on Air-Cleaved mica

    NARCIS (Netherlands)

    Bampoulis, Pantelis; Sotthewes, Kai; Siekman, Martin Herman; Zandvliet, Henricus J.W.; Poelsema, Bene

    2017-01-01

    The distribution of potassium (K+) ions on air-cleaved mica is important in many interfacial phenomena such as crystal growth, self-assembly and charge transfer on mica. However, due to experimental limitations to nondestructively probe single ions and ionic domains, their exact lateral organization

  17. Química de Heterociclos. Quinolina e isoquinolina

    OpenAIRE

    Collado, Daniel

    2014-01-01

    Quinolinas e isoquinolinas: propiedades. Reactividad química: SEAr, SNAr. Reacciones en cadenas laterales. Reacciones de quinolinio e isoquinolinio. Síntesis de quinolinas e isoquinolinas. Otros ciclos. Capítulo sexto de temario de la Asignatura Ampliación de Química Orgánica Avanzada. Quinolina e isoquinolina.

  18. Estudio de efectos dimensionales en pseudocerámicas ferroeléctricas

    Directory of Open Access Journals (Sweden)

    Melcón, M. J.

    1999-12-01

    Full Text Available With the objective to advance in the study of dimensional properties in ferroelectric materials, we have prepared a new kind of materials, which are going to be called “pseudoceramic”. These are, basically, composites that are constituted of milled single crystals packed tightly in different polymers. In these materials, we control, between other factors, grain-size and the thickness of polymeric matrix between grains. Therefore, we have a large range of pseudoceramics, over we study and measure ferro-piro-piezoelectric properties, and we related them with the dimensional aspects.

    Con el objetivo de avanzar en el estudio de la influencia de los parámetros dimensionales en las propiedades de materiales electrotérmicos, hemos fabricado materiales a los que llamaremos pseudocerámicas que, básicamente son composites de monocristales molidos embutidos en bases de diferentes polímeros. En estos materiales controlamos entre otros factores el tamaño de grano y el espesor de la matriz polimérica entre granos, disponiendo así de una amplia gama de pseudocerámicas en las que medimos y estudiamos propiedades ferro-piro-piezoeléctricas y las relacionamos con los aspectos dimensionales de las mismas. Se presentan los resultados correspondientes a la conformación del material y su respuesta eléctrica.

  19. Ensayo sobre endurecimiento de adhesivos estructurales sometidos a cargas dinámicas

    Directory of Open Access Journals (Sweden)

    Recuero, A.

    2004-04-01

    Full Text Available Carbon fibre reinforced polymers are increasingly replacing the steel reinforcing systems in the repair and strengthening of concrete structures thanks to their high strength/weight and stiffness/weight ratios, corrosion resistance, lightweight, and ease of handling and application. This paper presents a study on the behaviour of bridge concrete beams strengthened with CFRP sheets when the strengthening is made when traffic is acting so that the structure is subjected to dynamic loads while the adhesive is still fresh. No reduction in the effectiveness of the strengthening was observed in the tests.

    Los polímeros reforzados con fibras de carbono se están utilizando cada vez más para el refuerzo de estructuras de hormigón, reemplazando a los sistemas tradicionales de refuerzo con acero. Esto es debido a sus altas resistencia y rigidez específicas, resistencia a la corrosión, ligereza y facilidad de manejo y puesta en obra. Este artículo presenta un estudio sobre el comportamiento de vigas de puentes reforzadas con bandas de CFRP mientras se mantiene el puente en servicio de manera que la estructura está sometida a cargas dinámicas con el adhesivo fresco. En los ensayos realizados se ha observado que las cargas dinámicas no afectan a la efectividad del refuerzo.

  20. Electroactive polymers for sensing

    Science.gov (United States)

    2016-01-01

    Electromechanical coupling in electroactive polymers (EAPs) has been widely applied for actuation and is also being increasingly investigated for sensing chemical and mechanical stimuli. EAPs are a unique class of materials, with low-moduli high-strain capabilities and the ability to conform to surfaces of different shapes. These features make them attractive for applications such as wearable sensors and interfacing with soft tissues. Here, we review the major types of EAPs and their sensing mechanisms. These are divided into two classes depending on the main type of charge carrier: ionic EAPs (such as conducting polymers and ionic polymer–metal composites) and electronic EAPs (such as dielectric elastomers, liquid-crystal polymers and piezoelectric polymers). This review is intended to serve as an introduction to the mechanisms of these materials and as a first step in material selection for both researchers and designers of flexible/bendable devices, biocompatible sensors or even robotic tactile sensing units. PMID:27499846

  1. Superabsorbent polymer; Kokyushusei porima

    Energy Technology Data Exchange (ETDEWEB)

    Fujita, M. [Sanyo Kasei Kogyo K.K., Tokyo (Japan)

    1996-07-20

    Superabsorbent polymer (SAP) which has the absorbing ability from several hundreds to thousand times of the dead weight possesses many other functions in addition to the absorbing function, and studies on its application to various fields have been carried on very actively. Particularly, about 90% of the demand is for the application to body fluid absorber in the fields of sanitary materials. Basic water absorption mechanism, kinds, production methods, special features and applied cases of superabsorbent polymer are introduced. SAP is structured by loosely bridged water soluble polymer, particularly polymer electrolyte, to provide water unsoluble and water swelling properties. The kinds and production methods of SAP are described. SAP has respiration property in addition to the high water absorbing power and water holding ability. It has carboxyl ions, and has ammonia absorption ability and polyvalent metal ion adsorption ability. Paper diapers, water holding materials for soil, and cold reserving materials are discussed as examples of SAP application. 3 refs., 2 figs., 1 tab.

  2. Rheology of Supramolecular Polymers

    DEFF Research Database (Denmark)

    Shabbir, Aamir

    Supramolecular polymers are a broad class of materials that include all polymerscapable of associating via secondary interactions. These materials represent an emerging class of systems with superior versatility compared to classical polymers with applications in food stuff, coatings, cost...... efficient processes or biomedical areas. Design and development of supramolecular polymers using ionic, hydrogen bonding or transition metal complexes with tailored properties requires deep understanding of dynamics both in linear and non-linear deformations. While linear rheology is important to understand...... the dynamics under equilibrium conditions, extensional rheology is relevant during the processing or in the usage of polymers utilizing supramolecular associations for example, acrylic based pressure sensitive adhesives are subjected to extensional deformations during the peeling where strain hardening...

  3. Piezoelectricity in polymers

    International Nuclear Information System (INIS)

    Kepler, R.G.; Anderson, R.A.

    1980-01-01

    Piezoelectricity and related properties of polymers are reviewed. After presenting a historical overview of the field, the mathematical basis of piezo- and pyroelectricity is summarized. We show how the experimentally measured quantities are related to the changes in polarization and point out the serious inequlity between direct and converse piezoelectric coefficients in polymers. Theoretical models of the various origins of piezo- and pyroelectricity, which include piezoelectricity due to inhomogeneous material properties and strains, are reviewed. Relaxational effects are also considered. Experimental techniques are examined and the results for different materials are presented. Because of the considerable work in recent years polyimylidene fluoride, this polymer receives the majority of the attention. The numerous applications of piezo-and pyroelectric polymers are mentioned. This article concludes with a discussion of the possible role of piezo- and pyroelectricity in biological system

  4. Conjugated Polymer Solar Cells

    National Research Council Canada - National Science Library

    Paraschuk, Dmitry Y

    2006-01-01

    This report results from a contract tasking Moscow State University as follows: Conjugated polymers are promising materials for many photonics applications, in particular, for photovoltaic and solar cell devices...

  5. Polymers for Protein Conjugation

    Directory of Open Access Journals (Sweden)

    Gianfranco Pasut

    2014-01-01

    Full Text Available Polyethylene glycol (PEG at the moment is considered the leading polymer for protein conjugation in view of its unique properties, as well as to its low toxicity in humans, qualities which have been confirmed by its extensive use in clinical practice. Other polymers that are safe, biodegradable and custom-designed have, nevertheless, also been investigated as potential candidates for protein conjugation. This review will focus on natural polymers and synthetic linear polymers that have been used for protein delivery and the results associated with their use. Genetic fusion approaches for the preparation of protein-polypeptide conjugates will be also reviewed and compared with the best known chemical conjugation ones.

  6. Reactive polymer fused deposition manufacturing

    Science.gov (United States)

    Kunc, Vlastimil; Rios, Orlando; Love, Lonnie J.; Duty, Chad E.; Johs, Alexander

    2017-05-16

    Methods and compositions for additive manufacturing that include reactive or thermosetting polymers, such as urethanes and epoxies. The polymers are melted, partially cross-linked prior to the depositing, deposited to form a component object, solidified, and fully cross-linked. These polymers form networks of chemical bonds that span the deposited layers. Application of a directional electromagnetic field can be applied to aromatic polymers after deposition to align the polymers for improved bonding between the deposited layers.

  7. Otra ciencia económica

    Directory of Open Access Journals (Sweden)

    Daniel Innerarity

    2012-04-01

    Full Text Available El autor hace una crítica a la pretensión de la ciencia económica de constituirse como un saber exacto e hiperespecializado al considerar que esta pretensión se ha traducido en una pérdida de la capacidad que es necesaria para comprender la complejidad social de las realidades económicas. Seducida por el objetivo de la exactitud, la economía parece haber olvidado su carácter de construcción social. Además, la economía ha olvidado que es una más entre las ciencias sociales y el largo periodo en el que se ha separado de ellas reivindicando su plena autonomía no ha sido satisfactorio ni para ella ni para el resto de las ciencias sociales. Según el autor la crítica al capitalismo contemporáneo, si quiere ser más radical que moralizante, debe dirigirse a combatir el supuesto realismo de la ciencia económica dominante.The author criticizes the pretension of economic sciences of being an exact science and its tendency to specialization. The consequences of those pretensions are a loss of its capacity to understand the social complexity of the economic realities. The economy, seduced by its aim of exactitude, seems to forget that it is a social construction. Moreover, economy seems to forget that it is just a social science, and for a long period of time economy evolved as a separated and autonomous science; that time was not good neither for economic science neither for social sciences in general. According to the author, if we want to build a more radical and not only moralizing critique to contemporary capitalism, we must criticize the hypothetical realism of the economic science. 

  8. Radiation treated propylene polymers

    International Nuclear Information System (INIS)

    Hoffman, W.A. III; Baum, G.A.

    1982-01-01

    A method is provided for imparting improved strength and discoloration resistance to a stabilized propylene polymer that is to be exposed to a sterilizing dose of radiation. From 200 to 400 ppm of a phenolic antioxidant containing an isocyanurate group in its molecular structure, and a thiosynergist in an amount at least 6 times the weight of the antioxidant, are incorporated into the polymer before irradiation

  9. Interfaced conducting polymers

    Czech Academy of Sciences Publication Activity Database

    Stejskal, Jaroslav; Bober, Patrycja; Trchová, Miroslava; Nuzhnyy, Dmitry; Bovtun, Viktor; Savinov, Maxim; Petzelt, Jan; Prokeš, J.

    2017-01-01

    Roč. 224, February (2017), s. 109-115 ISSN 0379-6779 R&D Projects: GA ČR(CZ) GA16-02787S Institutional support: RVO:61389013 ; RVO:68378271 Keywords : polyaniline * polypyrrole * poly(p-phenylenediamine) Subject RIV: CD - Macromolecular Chemistry; CD - Macromolecular Chemistry (FZU-D) OBOR OECD: Polymer science; Polymer science (FZU-D) Impact factor: 2.435, year: 2016

  10. Sulfur polymer cement concrete

    International Nuclear Information System (INIS)

    Weber, H.H.; McBee, W.C.

    1990-01-01

    Sulfur-based composite materials formulated using sulfur polymer cement (SPC) and mineral aggregates are described and compared with conventional portland cement based materials. Materials characteristics presented include mechanical strength, chemical resistance, impact resistance, moisture permeation, and linear shrinkage during placement and curing. Examples of preparation and placement of sulfur polymer cement concrete (SC) are described using commercial scale equipment. SC applications presented are focused into hostile chemical environments where severe portland cement concrete (PCC) failure has occurred

  11. Radiation chemistry of polymers

    International Nuclear Information System (INIS)

    Charlesby, A.

    1987-01-01

    There are several and quite distinct major fields of interest discussed in this paper. The first deals with the modification of existing polymers either by main-chain scission or by cross-linking; the theories of these patterns of behavior are summarized here, and typical examples of polymers that show these alternative reactions are given. These are not comprehensive to avoid this presentation becoming a catalog of similar patterns of behavior

  12. Rapid Polymer Sequencer

    Science.gov (United States)

    Stolc, Viktor (Inventor); Brock, Matthew W (Inventor)

    2013-01-01

    Method and system for rapid and accurate determination of each of a sequence of unknown polymer components, such as nucleic acid components. A self-assembling monolayer of a selected substance is optionally provided on an interior surface of a pipette tip, and the interior surface is immersed in a selected liquid. A selected electrical field is impressed in a longitudinal direction, or in a transverse direction, in the tip region, a polymer sequence is passed through the tip region, and a change in an electrical current signal is measured as each polymer component passes through the tip region. Each of the measured changes in electrical current signals is compared with a database of reference electrical change signals, with each reference signal corresponding to an identified polymer component, to identify the unknown polymer component with a reference polymer component. The nanopore preferably has a pore inner diameter of no more than about 40 nm and is prepared by heating and pulling a very small section of a glass tubing.

  13. Aumentando la realidad química

    Directory of Open Access Journals (Sweden)

    Mª Luisa Roqueta Buj

    2017-08-01

    Full Text Available El uso de nuevas tecnologías como la Realidad Aumentada en la enseñanza de la Química permite manejar información virtual y asociarla a elementos de la vida real. Se accede a la misma a través de un dispositivo tecnológico con un software específico. Esta herramienta tecnológica recibe el nombre de Realidad Aumentada y permite añadir contenido digital a nuestro mundo real aumentando la percepción que tenemos del mismo. Nos permite incorporar contenido en forma de texto, imagen, audio o vídeo.

  14. LA CRISIS ECONÓMICA MUNDIAL

    Directory of Open Access Journals (Sweden)

    Julián Sabogal Tamayo

    2008-07-01

    Full Text Available Se argumenta el contenido de la actual crisis mundial, entendida como propia del movimiento cíclico del sistema capitalista y no como una crisis particularmente financiera. Se sostiene que las crisis económicas son propias del sistema, mas no de la economía perse. Se sustenta su diferencia con respecto a la crisis cíclica de 1929-1933 con base los ciclos sistémicos y las características diferentes de los inicios y el final del ciclo; al final del ciclo el capital es en su mayor parte financiero. Finalmente se sostiene la tesis que las crisis cíclicas, por tener causas objetivas, son inevitables, la única alternativa es buscar otra forma de organizar la sociedad y la producción: pasar de la búsqueda de rentabilidad a la satisfacción de las necesidades de toda la comunidad.

  15. de la química

    Directory of Open Access Journals (Sweden)

    Gregorio Jiménez-Valverde

    2006-01-01

    Full Text Available En la presente comunicación se detalla una innovadora experiencia llevada a cabo durante los cursos 2001-02 y 2002-03 consistente en el uso del BSCW, un entorno telemático para el trabajo cooperativo, en el Ciclo Formativo de Grado Superior de Química Ambiental. En el artículo se detallan las principales características del entorno, cómo fue aplicado y los resultados que se obtuvieron, presentados en páginas web creadas por los propios estudiantes sobre diferentes aspectos de metales en aguas. El alumnado, a través de una encuesta, respaldó esta experiencia y mostró una actitud muy positiva en la creación de materiales hipermedia.

  16. Precursor polymer compositions comprising polybenzimidazole

    Science.gov (United States)

    Klaehn, John R.; Peterson, Eric S.; Orme, Christopher J.

    2015-07-14

    Stable, high performance polymer compositions including polybenzimidazole (PBI) and a melamine-formaldehyde polymer, such as methylated, poly(melamine-co-formaldehyde), for forming structures such as films, fibers and bulky structures. The polymer compositions may be formed by combining polybenzimidazole with the melamine-formaldehyde polymer to form a precursor. The polybenzimidazole may be reacted and/or intertwined with the melamine-formaldehyde polymer to form the polymer composition. For example, a stable, free-standing film having a thickness of, for example, between about 5 .mu.m and about 30 .mu.m may be formed from the polymer composition. Such films may be used as gas separation membranes and may be submerged into water for extended periods without crazing and cracking. The polymer composition may also be used as a coating on substrates, such as metal and ceramics, or may be used for spinning fibers. Precursors for forming such polymer compositions are also disclosed.

  17. Polymer gel dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Baldock, C [Institute of Medical Physics, School of Physics, University of Sydney (Australia); De Deene, Y [Radiotherapy and Nuclear Medicine, Ghent University Hospital (Belgium); Doran, S [CRUK Clinical Magnetic Resonance Research Group, Institute of Cancer Research, Surrey (United Kingdom); Ibbott, G [Radiation Physics, UT M D Anderson Cancer Center, Houston, TX (United States); Jirasek, A [Department of Physics and Astronomy, University of Victoria, Victoria, BC (Canada); Lepage, M [Centre d' imagerie moleculaire de Sherbrooke, Departement de medecine nucleaire et de radiobiologie, Universite de Sherbrooke, Sherbrooke, QC (Canada); McAuley, K B [Department of Chemical Engineering, Queen' s University, Kingston, ON (Canada); Oldham, M [Department of Radiation Oncology, Duke University Medical Center, Durham, NC (United States); Schreiner, L J [Cancer Centre of South Eastern Ontario, Kingston, ON (Canada)], E-mail: c.baldock@physics.usyd.edu.au, E-mail: yves.dedeene@ugent.be

    2010-03-07

    Polymer gel dosimeters are fabricated from radiation sensitive chemicals which, upon irradiation, polymerize as a function of the absorbed radiation dose. These gel dosimeters, with the capacity to uniquely record the radiation dose distribution in three-dimensions (3D), have specific advantages when compared to one-dimensional dosimeters, such as ion chambers, and two-dimensional dosimeters, such as film. These advantages are particularly significant in dosimetry situations where steep dose gradients exist such as in intensity-modulated radiation therapy (IMRT) and stereotactic radiosurgery. Polymer gel dosimeters also have specific advantages for brachytherapy dosimetry. Potential dosimetry applications include those for low-energy x-rays, high-linear energy transfer (LET) and proton therapy, radionuclide and boron capture neutron therapy dosimetries. These 3D dosimeters are radiologically soft-tissue equivalent with properties that may be modified depending on the application. The 3D radiation dose distribution in polymer gel dosimeters may be imaged using magnetic resonance imaging (MRI), optical-computerized tomography (optical-CT), x-ray CT or ultrasound. The fundamental science underpinning polymer gel dosimetry is reviewed along with the various evaluation techniques. Clinical dosimetry applications of polymer gel dosimetry are also presented. (topical review)

  18. Polymer Directed Protein Assemblies

    Directory of Open Access Journals (Sweden)

    Patrick van Rijn

    2013-05-01

    Full Text Available Protein aggregation and protein self-assembly is an important occurrence in natural systems, and is in some form or other dictated by biopolymers. Very obvious influences of biopolymers on protein assemblies are, e.g., virus particles. Viruses are a multi-protein assembly of which the morphology is dictated by poly-nucleotides namely RNA or DNA. This “biopolymer” directs the proteins and imposes limitations on the structure like the length or diameter of the particle. Not only do these bionanoparticles use polymer-directed self-assembly, also processes like amyloid formation are in a way a result of directed protein assembly by partial unfolded/misfolded biopolymers namely, polypeptides. The combination of proteins and synthetic polymers, inspired by the natural processes, are therefore regarded as a highly promising area of research. Directed protein assembly is versatile with respect to the possible interactions which brings together the protein and polymer, e.g., electrostatic, v.d. Waals forces or covalent conjugation, and possible combinations are numerous due to the large amounts of different polymers and proteins available. The protein-polymer interacting behavior and overall morphology is envisioned to aid in clarifying protein-protein interactions and are thought to entail some interesting new functions and properties which will ultimately lead to novel bio-hybrid materials.

  19. Supercritical transitiometry of polymers.

    Science.gov (United States)

    Randzio, S L; Grolier, J P

    1998-06-01

    Employing supercritical fluids (SCFs) during polymers processing allows the unusual properties of SCFs to be exploited for making polymer products that cannot be obtained by other means. A new supercritical transitiometer has been constructed to permit study of the interactions of SCFs with polymers during processing under well-defined conditions of temperature and pressure. The supercritical transitiometer allows pressure to be exerted by either a supercritical fluid or a neutral medium and enables simultaneous determination of four basic parameters of a transition, i.e., p, T, Δ(tr)H and Δ(tr)V. This permits determination of the SCF effect on modification of the polymer structure at a given pressure and temperature and defines conditions to allow reproducible preparation of new polymer structures. Study of a semicrystalline polyethylene by this method has defined conditions for preparation of new microfoamed phases with good mechanical properties. The low densities and microporous structures of the new materials may make them useful for applications in medicine, pharmacy, or the food industry, for example.

  20. Multifunctional Polymer Nanocomposites

    Science.gov (United States)

    Galaska, Alexandra Maria; Song, Haixiang; Guo, Zhanhu

    With more awareness of energy conversion/storage and saving, different strategies have been developed to utilize the sustainable and renewable energy. Introducing nanoscale fillers can make inert polymer matrix possess unique properties to satisfy certain functions. For example, alumina nanoparticles have strengthened the weak thermosetting polymers. A combined mixture of carbon nanofibers and magnetite nanoparticles have made the inert epoxy sensitive for magnetic field for sensing applications. Introducing silica nanoparticles into conductive polymers such as polyaniline has enhanced the giant magnetoresistance behaviors. The introduced nanoparticles have made the transparent polymer have the electromagnetic interference (EMI) shielding function while reduce the density significantly. With the desired miniaturization, the materials combining different functionalities have become importantly interesting. In this talk, methodologies to prepare nanocomposites and their effects on the produced nanocomposites will be discussed. A variety of advanced polymer nanocomposites will be introduced. Unique properties including mechanical, electrical, magnetoresistance etc. and the applications for environmental remediation, energy storage/saving, fire retardancy, electromagnetic interference shielding, and electronic devices will be presented.

  1. Vochysiaceae endémicas del Perú

    Directory of Open Access Journals (Sweden)

    Blanca León

    2013-10-01

    Full Text Available La familia Vochysiaceae es reconocida en el Perú por presentar cuatro géneros y 32 especies (Brako & Zarucchi, 1993; Ulloa Ulloa et al., 2004, todas árboles. En este trabajo reconocemos dos especies endémicas en el género Qualea. Estas especies endémicas han sido encontradas en la región Bosques Húmedos Amazónicos, entre los 100 y 160 m de altitud. Ninguna especie endémica se encuentra representada dentro del Sistema Nacional de Áreas Naturales Protegidas por el Estado.

  2. Preparation and characterization of aluminum based alloy - mica composites

    International Nuclear Information System (INIS)

    Rashid, M.A.; Shamim, A.

    1999-01-01

    In this work, six pallets each of 2.0 cm dia and 0.5 cm thickness were prepared by powder metallurgy; half of them also contained 1% mica-powder to form a composite. Inclusion of mica resulted in a decreased density and an increased porosity of the sample. Brinell hardness was found to be 21% less for the composite than for the pure alloy. Micro-graphs of different areas of the sample show uniform distribution of mica particles and avoids around them. (author)

  3. Rosaceae endémicas del Perú

    Directory of Open Access Journals (Sweden)

    Wilfredo Mendoza

    2013-10-01

    Full Text Available La familia Rosaceae es reconocida en el Perú por presentar 24 géneros y 113 especies (Brako & Zarucchi, 1993; Mendoza, 2005; Ulloa Ulloa et al., 2004, entre hierbas, arbustos y árboles. En este trabajo reconocemos 14 especies endémicas en cuatro géneros. Las especies endémicas se encuentran principalmente en las regiones Bosques Pluviales Montanos, Bosques Muy Húmedos Montanos y Páramo, entre los 1900 y 3800 m de altitud. Seis especies endémicas se encuentran representadas dentro del Sistema Nacional de Áreas Naturales Protegidas por el Estado.

  4. Hepatitis isquémica Ischemic hepatitis

    Directory of Open Access Journals (Sweden)

    Marcos Amuchástegui (h

    2006-10-01

    Full Text Available La hepatitis isquémica es una complicación sumamente infrecuente de cirugía cardiovascular. Las biopsias muestran necrosis centrolobulillar. El término de "hepatitis" fue propuesto debido al aumento de transaminasas similar a aquellas de origen infeccioso, e "isquémica" por falla en la perfusión hepática. Posteriormente se definió el término de hepatitis isquémica como cuadro de elevación aguda y reversible (dentro de las 72 horas de transaminasas de hasta 20 veces el valor normal, asociado a trastornos en la perfusión hepática, luego de haber excluido otras causas de hepatitis aguda o daño hepatocelular. Se describe el caso de un paciente de 53 años que consulta por dolor epigástrico de 12 h de evolución sin fiebre, náuseas ni vómitos, resistente a la medicación. Tenía antecedentes inmediatos de reemplazo de válvula aórtica, y estaba anticoagulado. Evolucionó con shock y fallo multiorgánico. El examen evidenció marcada ictericia y signos de taponamiento pericárdico, asociado a un aumento considerable de enzimas hepáticas. Un ecocardiograma informó signos de taponamiento cardíaco y ausencia de disección aórtica. Se decidió pericardiocentesis, extrayéndose 970 cc. de líquido sanguinolento, y hemodiálisis, con notable mejoría de su estado hemodinámico. Los valores enzimáticos disminuyeron. Los marcadores virales fueron negativos.Ischemic hepatitis is an uncommon cardiovascular surgery complication. Hepatic biopsies show centrolobulillar necrosis. The term "hepatitis" was proposed because of a raise in hepatic enzymes similar with infectious disease, and "ischemic" because of failure in hepatic perfusion. Ischemic hepatitis was then defined as an acute and reversible elevation of hepatic enzymes (within 72 h, associated with disturbance in hepatic perfusion after excluding other causes of acute hepatitis. A 53 year-old male presented complaining of a 12 h epigastric pain, without nausea or vomiting, resistant

  5. Flame spraying of polymers

    International Nuclear Information System (INIS)

    Varacalle, D.J. Jr.; Zeek, D.P.; Couch, K.W.; Benson, D.M.; Kirk, S.M.

    1997-01-01

    Statistical design-of-experiment studies of the thermal spraying of polymer powders are presented. Studies of the subsonic combustion (i.e., Flame) process were conducted in order to determine the quality and economics of polyester and urethane coatings. Thermally sprayed polymer coatings are of interest to several industries for anticorrosion applications, including the chemical, automotive, and aircraft industries. In this study, the coating design has been optimized for a site-specific application using Taguchi-type fractional-factorial experiments. Optimized coating designs are presented for the two powder systems. A substantial range of thermal processing conditions and their effect on the resultant polymer coatings is presented. The coatings were characterized by optical metallography, hardness testing, tensile testing, and compositional analysis. Characterization of the coatings yielded the thickness, bond strength, Knoop microhardness, roughness, deposition efficiency, and porosity. Confirmation testing was accomplished to verify the coating designs

  6. Nanostructured silicate polymer concrete

    Directory of Open Access Journals (Sweden)

    Figovskiy Oleg L'vovich

    2014-03-01

    Full Text Available It has been known that acid-resistant concretes on the liquid glass basis have high porosity (up to 18~20 %, low strength and insufficient water resistance. Significant increasing of silicate matrix strength and density was carried out by incorporation of special liquid organic alkali-soluble silicate additives, which block superficial pores and reduce concrete shrinkage deformation. It was demonstrated that introduction of tetrafurfuryloxisilane additive sharply increases strength, durability and shock resistance of silicate polymer concrete in aggressive media. The experiments showed, that the strength and density of silicate polymer concrete increase in case of decreasing liquid glass content. The authors obtained optimal content of silicate polymer concrete, which possesses increased strength, durability, density and crack-resistance. Diffusive permeability of concrete and its chemical resistance has been investigated in various corroding media.

  7. Semi-metallic polymers

    DEFF Research Database (Denmark)

    Bubnova, Olga; Khan, Zia Ullah; Wang, Hui

    2014-01-01

    Polymers are lightweight, flexible, solution-processable materials that are promising for low-cost printed electronics as well as for mass-produced and large-area applications. Previous studies demonstrated that they can possess insulating, semiconducting or metallic properties; here we report...... that polymers can also be semi-metallic. Semi-metals, exemplified by bismuth, graphite and telluride alloys, have no energy bandgap and a very low density of states at the Fermi level. Furthermore, they typically have a higher Seebeck coefficient and lower thermal conductivities compared with metals, thus being...... a Fermi glass to a semi-metal. The high Seebeck value, the metallic conductivity at room temperature and the absence of unpaired electron spins makes polymer semi-metals attractive for thermoelectrics and spintronics....

  8. 'Stuffed' conducting polymers

    DEFF Research Database (Denmark)

    Winther-Jensen, Bjørn; Chen, Jun; West, Keld

    2005-01-01

    Conducting polymers (CP) obtained by oxidative polymerization using iron(III) salts shrink when Fe(II) and the excess counter ions are washed out after polymerization. This phenomenon can be used to incorporate active molecules into the CP matrix via their addition to the wash liquid. In the pres......Conducting polymers (CP) obtained by oxidative polymerization using iron(III) salts shrink when Fe(II) and the excess counter ions are washed out after polymerization. This phenomenon can be used to incorporate active molecules into the CP matrix via their addition to the wash liquid....... In the present work we demonstrate this principle on three different CP's: polypyrrole (PPy), poly-terthiophene (PTTh) and poly(3,4-ethylenedioxy thiophene) (PEDT), using ferrocene as a model molecule to be trapped in the polymer films. (c) 2005 Elsevier Ltd. All rights reserved....

  9. Electric field induced dewetting at polymer/polymer interfaces

    NARCIS (Netherlands)

    Lin, Z.Q.; Kerle, T.; Russell, T.P.; Schäffer, E.; Steiner, U

    2002-01-01

    External electric fields were used to amplify interfacial fluctuations in the air/polymer/polymer system where one polymer dewets the other. Two different hydrodynamic regimes were found as a function of electric field strength. If heterogeneous nucleation leads to the formation of holes before the

  10. Polymer containing functional end groups is base for new polymers

    Science.gov (United States)

    Hirshfield, S. M.

    1971-01-01

    Butadiene is polymerized with lithium-p-lithiophenoxide to produce linear polymer containing oxy-lithium group at one end and active carbon-lithium group at other end. Living polymers represent new approach to preparation of difunctional polymers in which structural features, molecular weight, type and number of end groups are controlled.

  11. Adsorption of surfactants and polymers at interfaces

    Science.gov (United States)

    Rojas, Orlando Jose

    Surface tension and high-resolution laser light scattering experiments were used to investigate the adsorption of isomeric sugar-based surfactants at the air/liquid interface in terms of surfactant surface packing and rheology. Soluble monolayers of submicellar surfactant solutions exhibited a relatively viscous behavior. It was also proved that light scattering of high-frequency thermally-induced capillary waves can be utilized to study surfactant exchange between the surface and the bulk solution. Such analysis revealed the existence of a diffusional relaxation mechanism. A procedure based on XPS was developed for quantification, on an absolute basis, of polymer adsorption on mica and Langmuir-Blodgett cellulose films. The adsorption of cationic polyelectrolytes on negatively-charged solid surfaces was highly dependent on the polymer ionicity. It was found that the adsorption process is driven by electrostatic mechanisms. Charge overcompensation (or charge reversal) of mica occurred after adsorption of polyelectrolytes of ca. 50% charge density, or higher. It was demonstrated that low-charge-density polyelectrolytes adsorb on solid surfaces with an extended configuration dominated by loops and tails. In this case the extent of adsorption is limited by steric constraints. The conformation of the polyelectrolyte in the adsorbed layer is dramatically affected by the presence of salts or surfactants in aqueous solution. The phenomena which occur upon increasing the ionic strength are consistent with the screening of the electrostatic attraction between polyelectrolyte segments and solid surface. This situation leads to polyelectrolyte desorption accompanied by both an increase in the layer thickness and the range of the steric force. Adsorbed polyelectrolytes and oppositely charged surfactants readily associate at the solid/liquid interface. Such association induces polyelectrolyte desorption at a surfactant concentration which depends on the polyelectrolyte charge

  12. Raw and renewable polymers

    CSIR Research Space (South Africa)

    Joseph, S

    2010-01-01

    Full Text Available in the permeability of the membrane and HO H3C H3C H2C H2C HO OH NH NH OH O OC C n O O O O Fig. 4 Structure of Chitin Raw and Renewable Polymers promoting internal osmotic imbalances. This results in leaching of electrolytes and proteins. 2... is often lost. In most cases this denaturation is not reversible. R-CH-COOH NH2 w Amino acid H2N COOHR a Amino acid Fig. 5 Structure of amino acid Raw and Renewable Polymers The solubilities of proteins vary considerably based on compositions...

  13. Delocalization in polymer models

    CERN Document Server

    Jitomirskaya, S Yu; Stolz, G

    2003-01-01

    A polymer model is a one-dimensional Schroedinger operator composed of two finite building blocks. If the two associated transfer matrices commute, the corresponding energy is called critical. Such critical energies appear in physical models, an example being the widely studied random dimer model. Although the random models are known to have pure-point spectrum with exponentially localized eigenstates for almost every configuration of the polymers, the spreading of an initially localized wave packet is here proven to be at least diffusive for every configuration.

  14. Nanoparticles from Renewable Polymers

    Directory of Open Access Journals (Sweden)

    Frederik Roman Wurm

    2014-07-01

    Full Text Available The use of polymers from natural resources can bring many benefits for novel polymeric nanoparticle systems. Such polymers have a variety of beneficial properties such as biodegradability and biocompatibility, they are readily available on large scale and at low cost. As the amount of fossil fuels decrease, their application becomes more interesting even if characterization is in many cases more challenging due to structural complexity, either by broad distribution of their molecular weights polysaccharides, polyesters, lignin or by complex structure (proteins, lignin. This review summarizes different sources and methods for the preparation of biopolymer-based nanoparticle systems for various applications.

  15. Polymers at cryogenic temperatures

    CERN Document Server

    Fu, Shao-Yun

    2013-01-01

    Kalia and Fu's novel monograph covers cryogenic treatment, properties and applications of cryo-treated polymer materials. Written by numerous international experts, the twelve chapters in this book offer the reader a comprehensive picture of the latest findings and developments, as well as an outlook on the field. Cryogenic technology has seen remarkable progress in the past few years and especially cryogenic properties of polymers are attracting attention through new breakthroughs in space, superconducting, magnetic and electronic techniques. This book is a valuable resource for researchers, educators, engineers and graduate students in the field and at technical institutions.

  16. Polymers and colloids

    International Nuclear Information System (INIS)

    Schurtenberger, P.

    1996-01-01

    A wealth of structural information from colloid and polymer solutions on a large range of length scales can be obtained using small angle neutron scattering (SANS) experiments. After a general introduction to the field of soft condensed matter, I shall give a few selected examples on how SANS combined with suitable contrast variation schemes can be used to extract information on the size and conformation of polymer coils in solution and in the melt, and on the local structure and flexibility of polymerlike micelles and microemulsions. (author) 8 figs., tabs., 44 refs

  17. Polymers and colloids

    Energy Technology Data Exchange (ETDEWEB)

    Schurtenberger, P [ETH Zurich, Inst. fuer Polymere, Zurich (Switzerland)

    1996-11-01

    A wealth of structural information from colloid and polymer solutions on a large range of length scales can be obtained using small angle neutron scattering (SANS) experiments. After a general introduction to the field of soft condensed matter, I shall give a few selected examples on how SANS combined with suitable contrast variation schemes can be used to extract information on the size and conformation of polymer coils in solution and in the melt, and on the local structure and flexibility of polymerlike micelles and microemulsions. (author) 8 figs., tabs., 44 refs.

  18. Ballistic nanoindentation of polymers

    Science.gov (United States)

    Gotsmann, B.; Rothuizen, H.; Duerig, U.

    2008-09-01

    Indentation of a sharp (20 nm) cantilevered silicon tip into a polymer (SU8) surface is analyzed experimentally and through finite-element simulations. A rate effect on the microsecond scale that eases indentation is found, in contrast to the commonly observed hardening at high strain rates. The observed rate effect is discussed in terms of adiabatic heating and inertial force overshoot. The estimated magnitude of adiabatic heating is marginal, but the force overshoot itself is large enough to explain the data. The data imply that topographic patterning of a polymer at megahertz rates is feasible.

  19. Mechanically Invisible Polymer Coatings

    DEFF Research Database (Denmark)

    2014-01-01

    phase comprises particles, said particles comprising a filler material and an encapsulating coating of a second polymeric material, wherein the backbones of the first and second polymeric materials are the same. The composition may be used in electroactive polymers (EAPs) in order to obtain mechanically......The present invention relates to a composition comprising encapsulated particles in a polymeric material. The composition comprises a continuous phase and a discontinuous phase incorporated therein, wherein the continuous phase comprises a first polymeric material and wherein the discontinuous...... invisible polymer coatings....

  20. Antibacterial polymer coatings.

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, Mollye C.; Allen, Ashley N.; Barnhart, Meghan; Tucker, Mark David; Hibbs, Michael R.

    2009-09-01

    A series of poly(sulfone)s with quaternary ammonium groups and another series with aldehyde groups are synthesized and tested for biocidal activity against vegetative bacteria and spores, respectively. The polymers are sprayed onto substrates as coatings which are then exposed to aqueous suspensions of organisms. The coatings are inherently biocidal and do not release any agents into the environment. The coatings adhere well to both glass and CARC-coated coupons and they exhibit significant biotoxicity. The most effective quaternary ammonium polymers kills 99.9% of both gram negative and gram positive bacteria and the best aldehyde coating kills 81% of the spores on its surface.

  1. Polymer architecture and drug delivery.

    Science.gov (United States)

    Qiu, Li Yan; Bae, You Han

    2006-01-01

    Polymers occupy a major portion of materials used for controlled release formulations and drug-targeting systems because this class of materials presents seemingly endless diversity in topology and chemistry. This is a crucial advantage over other classes of materials to meet the ever-increasing requirements of new designs of drug delivery formulations. The polymer architecture (topology) describes the shape of a single polymer molecule. Every natural, seminatural, and synthetic polymer falls into one of categorized architectures: linear, graft, branched, cross-linked, block, star-shaped, and dendron/dendrimer topology. Although this topic spans a truly broad area in polymer science, this review introduces polymer architectures along with brief synthetic approaches for pharmaceutical scientists who are not familiar with polymer science, summarizes the characteristic properties of each architecture useful for drug delivery applications, and covers recent advances in drug delivery relevant to polymer architecture.

  2. Conducting polymer 3D microelectrodes

    DEFF Research Database (Denmark)

    Sasso, Luigi; Vazquez, Patricia; Vedarethinam, Indumathi

    2010-01-01

    Conducting polymer 3D microelectrodes have been fabricated for possible future neurological applications. A combination of micro-fabrication techniques and chemical polymerization methods has been used to create pillar electrodes in polyaniline and polypyrrole. The thin polymer films obtained...... showed uniformity and good adhesion to both horizontal and vertical surfaces. Electrodes in combination with metal/conducting polymer materials have been characterized by cyclic voltammetry and the presence of the conducting polymer film has shown to increase the electrochemical activity when compared...

  3. Shape memory polymer medical device

    Science.gov (United States)

    Maitland, Duncan [Pleasant Hill, CA; Benett, William J [Livermore, CA; Bearinger, Jane P [Livermore, CA; Wilson, Thomas S [San Leandro, CA; Small, IV, Ward; Schumann, Daniel L [Concord, CA; Jensen, Wayne A [Livermore, CA; Ortega, Jason M [Pacifica, CA; Marion, III, John E.; Loge, Jeffrey M [Stockton, CA

    2010-06-29

    A system for removing matter from a conduit. The system includes the steps of passing a transport vehicle and a shape memory polymer material through the conduit, transmitting energy to the shape memory polymer material for moving the shape memory polymer material from a first shape to a second and different shape, and withdrawing the transport vehicle and the shape memory polymer material through the conduit carrying the matter.

  4. Calcinosis en Esclerosis Sistémica

    Directory of Open Access Journals (Sweden)

    Tamara Caínzos Romero

    2014-12-01

    Full Text Available Paciente de 85 años diagnosticada de esclerosis sistémica con esclerodermia limitada de años de evolución con ANA positivos a título de 1:5120 patrón anticentrómero, antiScl-70 y anti-Jo negativos. Sus principales manifestaciones clínicas son: Raynaud grave y úlceras digitales a tratamiento con nifedipino y bosentán, hipertensión pulmonar leve, esclerodactilia y calcificación extensa de tejidos blandos en ambas manos, 4º dedo de mano derecha y 4º-5º dedos de mano izquierda, con deformidades en flexión bilaterales, que pueden observarse en estudios de radiografía simple de ambas manos. La calcinosis resulta del depósito de cristales de hidroxiapatita de calcio fundamentalmente. Aunque los resultados son, en general malos, se han utilizado diltiazem, colchicina y los AINES en los casos que se produce una reacción inflamatoria similar a la pseudogota, en los casos más graves es necesario recurrir a la cirugía.

  5. Mechanistic Indicators of Childhood Asthma (MICA): piloting ...

    Science.gov (United States)

    Background: Modem methods in molecular biology and advanced computational tools show promise in elucidating complex interactions that occur between genes and environmental factors in diseases such as asthma; however appropriately designed studies are critical for these methods to reach their full potential. Objective: We used a case-control study to investigate whether genomic data (blood gene expression), viewed together with a spectrum of exposure effects and susceptibility markers (blood, urine and nail), can provide a mechanistic explanation for the increased susceptibility of asthmatics to ambient air pollutants. Methods: We studied 205 non-asthmatic and asthmatic children, (9-12 years of age) who participated in a clinical study in Detroit, Michigan. The study combines a traditional epidemiological design with an integrative approach to investigate the environmental exposure of children to indoor-outdoor air. The study includes measurements of internal dose (metals, allergen specific IgE, PAH and VOC metabolites) and clinical measures of health outcome (immunological, cardiovascular and respiratory). Results: Expected immunological indications of asthma have been obtained. In addition, initial results from our analyses point to the complex nature of childhood health and risk factors linked to metabolic syndrome (obesity, blood pressure and dyslipidemia). For example, 31% and 34% of the asthmatic MICA subjects were either overweight (BMI > 25) o

  6. RF Characteristics of Mica-Z Wireless Sensor Network Motes

    National Research Council Canada - National Science Library

    Koh, Swee J

    2006-01-01

    ... network characteristics. Link-break and re-association distances with their corresponding RF power measurements were recorded to determine the Mica-Z s range characteristics under these different operating environments...

  7. CONFLICTO, VIOLENCIA SOCIOECONÓMICA Y DESPLAZAMIENTO FORZADO EN COLOMBIA

    Directory of Open Access Journals (Sweden)

    Andrés Felipe Mora Cortés

    2013-12-01

    Full Text Available Este artículo introduce el concepto de violencia socioeconómica, que se refiere a mecanismos de regulación de conflictos distributivos y prácticas gubernamentales que eliminan las condiciones base para la reproducción de la vida. Se identifican tres expresiones clave de la violencia socioeconómica: el despojo, la inseguridad económica y la no generación de oportunidades. El artículo insiste en el efecto desproporcionado que dichas expresiones de violencia socioeconómica tienen sobre la población desplazada; también defiende la necesidad de una agenda mínima que erradique la violencia como lógica reguladora de los conflictos distributivos y que sirva de base para la construcción de paz con justicia social en Colombia.

  8. Malvaceae endémicas del Perú

    Directory of Open Access Journals (Sweden)

    Magda Chanco

    2013-10-01

    Full Text Available La familia Malvaceae es reconocida en el Perú con 38 géneros y 264 especies (Brako & Zarucchi 1993, Ulloa et al. 2004, mayormente arbustos y hierbas. En este trabajo reconocemos 87 especies endémicas en 16 géneros. El género más rico en especies endémicas es Nototriche. Las especies endémicas se encuentran en varias regiones ecológicas, entre ellas Altoandina, Mesoandina y Puna Húmeda y Seca, por encima de los 2500 m, hasta alcanzar los límites de la vegetación a 5100 m de altitud. Se aplicaron las categorías y criterios de la UICN a 84 especies. Once especies endémicas se encuentran presentes en el Sistema Nacional de Áreas Naturales Protegidas por el Estado.

  9. Investigation of alpha emitters in fresh and powdered blood of fertile women: an in vitro application of CR-39 NTDs

    International Nuclear Information System (INIS)

    Salih, N.F.; University of Koya, Kurdistan; Jaafar, M.S.

    2014-01-01

    Blood samples were acquired from 60 women aged 20-44 years having decreased fertility, infertile or with uterine tumors in the Iraqi Kurdistan region. The concentrations of α emitters in fresh blood ranged from 0.0029 to 0.0088 ppm, whereas those in powdered blood ranged from 0.0036 ppm in Eiskan to 0.0096 ppm in Halabjay-Kon in Sulaymania. The α emitter concentrations in fresh blood ranged from 0.0029 to 0.0139 ppm, whereas those in powdered blood ranged from 0.0031 ppm in Shorsh to 0.0146 ppm in Sedakan in the Erbil Governorate. However, the concentrations of α emitters in the blood of women with decreased fertility were higher in the North than women from South Iraq. The difference significantly p < 0.001 revealed higher means of track density of fresh and powder blood in Erbil compared to Sulaymania. α are more damaging to the living tissue and exposure of the gonads leads to decreased fertility in women, most of data have been significant therefore, the result shown the radiation effect on women fertility. (author)

  10. Diagnosis of spatial resolution for microbeam scanning PIXE using STIM method and CR-39 track detector in PASTA

    International Nuclear Information System (INIS)

    Hamano, T.; Imaseki, H.; Yukawa, M.; Ishikawa, T.; Iso, H.; Matsumoto, K.

    2003-01-01

    In PIXE analysis system and Tandem Accelerator facility (PASTA) of NIRS, we are using Scanning Transmission Ion Microscopy (STIM) method and solid track detector to diagnose the spatial resolution of scanning microbeam PIXE analysis system. These methods are widely used by many microbeam facilities. (author)

  11. Determining of the track parameters in solid state nuclear track detectors Cr 39 due to alpha particles

    International Nuclear Information System (INIS)

    Kostic, D.; Nikezic, D.

    1997-01-01

    An equation of the etch pit wall is proposed to be used for simulation of the track growth and calculating the major and the minor axis of etch pit opening. Dependence on the following parameters is set up: distance along a track from the point where the particle entered the detector, ratio of the track etch wall to the bulk etch rate, integration constant determined from particle penetration depth and normal distance from the particle trajectory to the etch pit wall. The corresponding computer program was written. The input parameters of this program are: alpha particles energy, incidence angle and removed layer; the output gives track parameters. The results obtained by this method are compared to another approach given by Somogy and Szalay (1973) and a reasonably good agreement is found. (author)

  12. Frictional properties of confined polymers

    DEFF Research Database (Denmark)

    Sivebæk, Ion Marius; Samoilov, Vladimir N; Persson, Bo N J

    2008-01-01

    We present molecular dynamics friction calculations for confined hydrocarbon solids with molecular lengths from 20 to 1400 carbon atoms. Two cases are considered: a) polymer sliding against a hard substrate, and b) polymer sliding on polymer. In the first setup the shear stresses are relatively i...

  13. New polymers for phase partitioning

    Science.gov (United States)

    Harris, J. M.

    1981-01-01

    The synthesizing of several polyethylene glycols having crown ethers attached is reported. This work led to the identification of three new polymer types which promise to be more effective at selectively binding specific cell types. Work was completed on identification of chemical properties of the new polymer crowns and on development of new techniques for determination of polymer-phase composition.

  14. Nonlinear microstructured polymer optical fibres

    DEFF Research Database (Denmark)

    Frosz, Michael Henoch

    is potentially the case for microstructured polymer optical fibres (mPOFs). Another advantage is that polymer materials have a higher biocompatibility than silica, meaning that it is easier to bond certain types of biosensor materials to a polymer surface than to silica. As with silica PCFs, it is difficult...

  15. Reversible networks in supramolecular polymers

    NARCIS (Netherlands)

    Havermans - van Beek, D.J.M.

    2007-01-01

    Non–covalent interactions between low molecular weight polymers form the basis of supramolecular polymers. The material properties of such polymers are determined by the strength and lifetime of the non–covalent reversible interactions. Due to the reversibility of the interactions between the low

  16. Layered graphene-mica substrates induce melting of DNA origami

    Science.gov (United States)

    Green, Nathaniel S.; Pham, Phi H. Q.; Crow, Daniel T.; Burke, Peter J.; Norton, Michael L.

    2018-04-01

    Monolayer graphene supported on mica substrates induce melting of cross-shaped DNA origami. This behavior can be contrasted with the case of origami on graphene on graphite, where an expansion or partially re-organized structure is observed. On mica, only well-formed structures are observed. Comparison of the morphological differences observed for these probes after adsorption on these substrates provides insights into the sensitivity of DNA based nanostructures to the properties of the graphene monolayer, as modified by its substrate.

  17. White polymer light-emitting diode based on polymer blending

    International Nuclear Information System (INIS)

    Lee, Yong Kyun; Kwon, Soon Kab; Kim, Jun Young; Park, Tae Jin; Song, Dae Ho; Kwon, Jang Hyuk; Choo, Dong Jun; Jang, Jin; Jin, Jae Kyu; You, Hong

    2006-01-01

    A series of white polymer light emitting devices have been fabricated by using a polymer blending system of polyfluorene-based blue and MEH-PPV red polymers. A device structure of ITO/PEDOT:PSS/polymer/LiF/Al was employed. The white polymer device exhibited a current efficiency of 4.33 cd/A (4,816 cd/m 2 , Q.E. = 1.9 %) and a maximum luminance of 21,430 cd/m 2 at 9.2 V. The CIE coordinates were (0.35, 0.37) at 5 V and (0.29, 0.30) at 9 V.

  18. Polymers of phenylenediamines

    Czech Academy of Sciences Publication Activity Database

    Stejskal, Jaroslav

    2015-01-01

    Roč. 41, February (2015), s. 1-31 ISSN 0079-6700 R&D Projects: GA ČR(CZ) GA13-00270S Institutional support: RVO:61389013 Keywords : polyphenylenediamine * phenylenediamine * conducting polymers Subject RIV: CD - Macromolecular Chemistry Impact factor: 27.184, year: 2015

  19. Nanoporous thermosetting polymers.

    Science.gov (United States)

    Raman, Vijay I; Palmese, Giuseppe R

    2005-02-15

    Potential applications of nanoporous thermosetting polymers include polyelectrolytes in fuel cells, separation membranes, adsorption media, and sensors. Design of nanoporous polymers for such applications entails controlling permeability by tailoring pore size, structure, and interface chemistry. Nanoporous thermosetting polymers are often synthesized via free radical mechanisms using solvents that phase separate during polymerization. In this work, a novel technique for the synthesis of nanoporous thermosets is presented that is based on the reactive encapsulation of an inert solvent using step-growth cross-linking polymerization without micro/macroscopic phase separation. The criteria for selecting such a monomer-polymer-solvent system are discussed based on FTIR analysis, observed micro/macroscopic phase separation, and thermodynamics of swelling. Investigation of resulting network pore structures by scanning electron microscopy (SEM) and small-angle X-ray scattering following extraction and supercritical drying using carbon dioxide showed that nanoporous polymeric materials with pore sizes ranging from 1 to 50 nm can be synthesized by varying the solvent content. The differences in the porous morphology of these materials compared to more common free radically polymerized analogues that exhibit phase separation were evident from SEM imaging. Furthermore, it was demonstrated that the chemical activity of the nanoporous materials obtained by our method could be tailored by grafting appropriate functional groups at the pore interface.

  20. Characterization of healable polymers

    Science.gov (United States)

    Nielsen, C.; Weizman, Or; Nemat-Nasser, Sia

    2010-04-01

    Materials with an internal mechanism for damage repair would be valuable in isolated environments where access is difficult or impossible. Current work is focused on characterizing neat polymers with reformable cross-linking bonds. These bonds are thermally reversible, the result of a Diels-Alder cycloaddition between furan and maleimide monomers. Candidate polymers are examined using modulated differential scanning calorimetry (DSC) to confirm the presence of reversible bonding. One polymer, 2MEP3FT, was expected to have these bonds, but none were observed. A second polymer, 2MEP4FS, with a modified furan monomer does exhibit reversible bonding. Further DSC testing and dynamic mechanical thermal analyses (DMA) are conducted to determine material properties such as glass transition temperature, storage modulus and quality of the polymerization. Healing efficiency is established using the double cleavage drilled compression (DCDC) fracture test. A column of material with a central hole is subjected to axial compression, driving cracks up and down the sample. After unloading, the cracks are healed, and the sample is retested. Comparing the results gives a quantitative evaluation of healing.

  1. Knots in polymers

    Indian Academy of Sciences (India)

    Abstract. Knots and topological entanglements play an important role in the statistical mechanics of polymers. While topological entanglement is a global property, it is possible to study the size of a knotted region both numerically and analytically. It can be shown that long-range repulsive interactions, as well as entropy ...

  2. Polyester polymer concrete overlay.

    Science.gov (United States)

    2013-01-01

    Polyester polymer concrete (PPC) was used in a trial application on a section of pavement that suffers from extensive studded tire wear. The purpose of the trial section is to determine if PPC is a possible repair strategy for this type of pavement d...

  3. Conductive polymer composition

    NARCIS (Netherlands)

    2010-01-01

    The present invention relates to a process for the preparation of a conductive polymer composition comprising graphene and the articles obtained by this process. The process comprises the following steps: A) contacting graphite oxide in an aqueous medium with a water-soluble or dispersible

  4. BEAM applications to polymer materials

    International Nuclear Information System (INIS)

    Tagawa, Seiichi

    1994-01-01

    Recently papers about beam applications to polymers have been increasing rapidly both in the fundamental and applied fields. Fairly large number of papers have been published in the fundamental aspects of radiation effects of beam applications to polymers such as pulse radiolysis and high density electronic excitation effects. A number of papers have been published in the more applied aspects of beam applications to polymers such as radiation processing and curing. The present paper describes recent beam applications to polymers. 1. Radiation Effects on Polymers; Radiation effects on polymers have been studied for more than 40 years. Most of work on radiation effects on polymers has been carried out by using high energy photon (gamma-ray) and electron beams, since polymers are sensitive to any kinds of ionizing radiation. Even non-ionizing radiation such as ultraviolet and visible light excites electronic excited states of polymers and then photo-chemical reactions of polymers are induced from the electronic excited states. Studies on radiation effects of other ionizing radiation on polymers have not been so popular for a long time. Recently application of new radiation such as ion beams to polymers have been worthy of remark in fields of advanced science and technology, since new radiation beams induce different radiation effects from those induced by high energy gamma-rays and electrons. 2. Beam Applications of Polymers; Recent progress in beam applications to polymers such as radiation processing and curing, x-ray and electron beam microlithography, and applications of new beams such as ion beams to polymers has been reviewed. (author)

  5. Transparent Indium Tin Oxide Electrodes on Muscovite Mica for High-Temperature-Processed Flexible Optoelectronic Devices.

    Science.gov (United States)

    Ke, Shanming; Chen, Chang; Fu, Nianqing; Zhou, Hua; Ye, Mao; Lin, Peng; Yuan, Wenxiang; Zeng, Xierong; Chen, Lang; Huang, Haitao

    2016-10-26

    Sn-doped In 2 O 3 (ITO) electrodes were deposited on transparent and flexible muscovite mica. The use of mica substrate makes a high-temperature annealing process (up to 500 °C) possible. ITO/mica retains its low electric resistivity even after continuous bending of 1000 times on account of the unique layered structure of mica. When used as a transparent flexible heater, ITO/mica shows an extremely fast ramping (solar cells (PSCs) with high efficiency.

  6. Conducting Polymers for Neutron Detection

    International Nuclear Information System (INIS)

    Clare Kimblin; Kirk Miller; Bob Vogel; Bill Quam; Harry McHugh; Glen Anthony; Steve Jones; Mike Grover

    2007-01-01

    Conjugated polymers have emerged as an attractive technology for large-area electronic applications. As organic semiconductors, they can be used to make large-area arrays of diodes or transistors using fabrication techniques developed for polymer coatings, such as spraying and screen-printing. We have demonstrated both neutron and alpha detection using diodes made from conjugated polymers and have done preliminary work to integrate a boron carbide layer into the conventional polymer device structure to capture thermal neutrons. The polymer devices appear to be insensitive to gamma rays, due to their small physical thickness and low atomic number

  7. Gel polymer electrolytes for batteries

    Science.gov (United States)

    Balsara, Nitash Pervez; Eitouni, Hany Basam; Gur, Ilan; Singh, Mohit; Hudson, William

    2014-11-18

    Nanostructured gel polymer electrolytes that have both high ionic conductivity and high mechanical strength are disclosed. The electrolytes have at least two domains--one domain contains an ionically-conductive gel polymer and the other domain contains a rigid polymer that provides structure for the electrolyte. The domains are formed by block copolymers. The first block provides a polymer matrix that may or may not be conductive on by itself, but that can soak up a liquid electrolyte, thereby making a gel. An exemplary nanostructured gel polymer electrolyte has an ionic conductivity of at least 1.times.10.sup.-4 S cm.sup.-1 at 25.degree. C.

  8. POLYMER ELECTROLYTE MEMBRANE FUEL CELLS

    DEFF Research Database (Denmark)

    2001-01-01

    A method for preparing polybenzimidazole or polybenzimidazole blend membranes and fabricating gas diffusion electrodes and membrane-electrode assemblies is provided for a high temperature polymer electrolyte membrane fuel cell. Blend polymer electrolyte membranes based on PBI and various...... thermoplastic polymers for high temperature polymer electrolyte fuel cells have also been developed. Miscible blends are used for solution casting of polymer membranes (solid electrolytes). High conductivity and enhanced mechanical strength were obtained for the blend polymer solid electrolytes....... With the thermally resistant polymer, e.g., polybenzimidazole or a mixture of polybenzimidazole and other thermoplastics as binder, the carbon-supported noble metal catalyst is tape-cast onto a hydrophobic supporting substrate. When doped with an acid mixture, electrodes are assembled with an acid doped solid...

  9. Adsorption and flocculation by polymers and polymer mixtures.

    Science.gov (United States)

    Gregory, John; Barany, Sandor

    2011-11-14

    Polymers of various types are in widespread use as flocculants in several industries. In most cases, polymer adsorption is an essential prerequisite for flocculation and kinetic aspects are very important. The rates of polymer adsorption and of re-conformation (relaxation) of adsorbed chains are key factors that influence the performance of flocculants and their mode of action. Polyelectrolytes often tend to adopt a rather flat adsorbed configuration and in this state their action is mainly through charge effects, including 'electrostatic patch' attraction. When the relaxation rate is quite low, particle collisions may occur while the adsorbed chains are still in an extended state and flocculation by polymer bridging may occur. These effects are now well understood and supported by much experimental evidence. In recent years there has been considerable interest in the use of multi-component flocculants, especially dual-polymer systems. In the latter case, there can be significant advantages over the use of single polymers. Despite some complications, there is a broad understanding of the action of dual polymer systems. In many cases the sequence of addition of the polymers is important and the pre-adsorbed polymer can have two important effects: providing adsorption sites for the second polymer or causing a more extended adsorbed conformation as a result of 'site blocking'. Copyright © 2011 Elsevier B.V. All rights reserved.

  10. Structure and Dynamics of Polymer/Polymer grafted nanoparticle composite

    Science.gov (United States)

    Archer, Lynden

    Addition of nanoparticles to polymers is a well-practiced methodology for augmenting various properties of the polymer host, including mechanical strength, thermal stability, barrier properties, dimensional stability and wear resistance. Many of these property changes are known to arise from nanoparticle-induced modification of polymer structure and chain dynamics, which are strong functions of the dispersion state of the nanoparticles' and on their relative size (D) to polymer chain dimensions (e.g. Random coil radius Rg or entanglement mesh size a) . This talk will discuss polymer nanocomposites (PNCs) comprised of Polyethylene Glycol (PEG) tethered silica nanoparticles (SiO2-PEG) dispersed in polymers as model systems for investigating phase stability and dynamics of PNCs. On the basis of small-angle X-ray Scattering, it will be shown that favorable enthalpic interactions between particle-tethered chains and a polymer host provides an important mechanism for creating PNCs in which particle aggregation is avoided. The talk will report on polymer and particle scale dynamics in these materials and will show that grafted nanoparticles well dispersed in a polymer host strongly influence the host polymer relaxation dynamics on all timescales and the polymers in turn produce dramatic changes in the nature (from diffusive to hyperdiffusive) and speed of nano particle decorrelation dynamics at the polymer entanglement threshold. A local viscosity model capable of explaining these observations is discussed and the results compared with scaling theories for NP motions in polymers This material is based on work supported by the National Science Foundation Award Nos. DMR-1609125 and CBET-1512297.

  11. Estudo da modificação química de polidienos do tipo SBR e BR Study of chemical modification of SBR and BR polydiene

    Directory of Open Access Journals (Sweden)

    Tatiana L. A. C. Rocha

    2004-12-01

    Full Text Available A utilização de modificações químicas de polidienos comerciais tem sido estudada como um meio alternativo à síntese de novos polímeros, para otimização das propriedades finais destes materiais através da introdução de diferentes grupamentos reativos na cadeia polimérica. A modificação química pode ser feita através de diferentes métodos, os quais podem ser realizados tanto em solução como em massa, onde podem ser destacadas as reações de epoxidação, sulfonação, maleinização, carboxilação, etc. Neste trabalho foi estudado o método de epoxidação de borrachas do tipo SBR e BR. Foi possível observar que mesmo pequenos graus de modificação química causam mudanças marcantes nas propriedades finais dos polímeros, como determinado para a temperatura de transição vítrea.Chemical modification of polydiene has been studied as an alternative route to obtain modified polymers with improved final properties. This improvement is due to the introduction of different kinds of reactive groups into a polymer chain, and it can be done in solution as well as in bulk. The chemical modification can be carried out by different methods such as epoxidation, maleination, carboxylation, sulfonation etc. In this work we show that in the epoxidation of SBR and BR even a small degree of modification can change the final properties of the polymer, as it occurred for the glass transition temperature.

  12. How do polymers degrade?

    Science.gov (United States)

    Lyu, Suping

    2011-03-01

    Materials derived from agricultural products such as cellulose, starch, polylactide, etc. are more sustainable and environmentally benign than those derived from petroleum. However, applications of these polymers are limited by their processing properties, chemical and thermal stabilities. For example, polyethylene terephthalate fabrics last for many years under normal use conditions, but polylactide fabrics cannot due to chemical degradation. There are two primary mechanisms through which these polymers degrade: via hydrolysis and via oxidation. Both of these two mechanisms are related to combined factors such as monomer chemistry, chain configuration, chain mobility, crystallinity, and permeation to water and oxygen, and product geometry. In this talk, we will discuss how these materials degrade and how the degradation depends on these factors under application conditions. Both experimental studies and mathematical modeling will be presented.

  13. Dielectric Actuation of Polymers

    Science.gov (United States)

    Niu, Xiaofan

    Dielectric polymers are widely used in a plurality of applications, such as electrical insulation, dielectric capacitors, and electromechanical actuators. Dielectric polymers with large strain deformations under an electric field are named dielectric elastomers (DE), because of their relative low modulus, high elongation at break, and outstanding resilience. Dielectric elastomer actuators (DEA) are superior to traditional transducers as a muscle-like technology: large strains, high energy densities, high coupling efficiency, quiet operation, and light weight. One focus of this dissertation is on the design of DE materials with high performance and easy processing. UV radiation curing of reactive species is studied as a generic synthesis methodology to provide a platform for material scientists to customize their own DE materials. Oligomers/monomers, crosslinkers, and other additives are mixed and cured at appropriate ratios to control the stress-strain response, suppress electromechanical instability of the resulting polymers, and provide stable actuation strains larger than 100% and energy densities higher than 1 J/g. The processing is largely simplified in the new material system by removal of the prestretching step. Multilayer stack actuators with 11% linear strain are demonstrated in a procedure fully compatible with industrial production. A multifunctional DE derivative material, bistable electroactive polymer (BSEP), is invented enabling repeatable rigid-to-rigid deformation without bulky external structures. Bistable actuation allows the polymer actuator to have two distinct states that can support external load without device failure. Plasticizers are used to lower the glass transition temperature to 45 °C. Interpenetrating polymer network structure is established inside the BSEP to suppress electromechanical instability, providing a breakdown field of 194 MV/m and a stable bistable strain as large as 228% with a 97% strain fixity. The application of BSEP

  14. Polymer Physics Prize Talk

    Science.gov (United States)

    Olvera de La Cruz, Monica

    Polymer electrolytes have been particularly difficult to describe theoretically given the large number of disparate length scales involved in determining their physical properties. The Debye length, the Bjerrum length, the ion size, the chain length, and the distance between the charges along their backbones determine their structure and their response to external fields. We have developed an approach that uses multi-scale calculations with the capability of demonstrating the phase behavior of polymer electrolytes and of providing a conceptual understanding of how charge dictates nano-scale structure formation. Moreover, our molecular dynamics simulations have provided an understanding of the coupling of their conformation to their dynamics, which is crucial to design self-assembling materials, as well as to explore the dynamics of complex electrolytes for energy storage and conversion applications.

  15. Conjugated polymer nanoparticles, methods of using, and methods of making

    KAUST Repository

    Habuchi, Satoshi

    2017-03-16

    Embodiments of the present disclosure provide for conjugated polymer nanoparticle, method of making conjugated polymer nanoparticles, method of using conjugated polymer nanoparticle, polymers, and the like.

  16. Conjugated polymer nanoparticles, methods of using, and methods of making

    KAUST Repository

    Habuchi, Satoshi; Piwonski, Hubert Marek; Michinobu, Tsuyoshi

    2017-01-01

    Embodiments of the present disclosure provide for conjugated polymer nanoparticle, method of making conjugated polymer nanoparticles, method of using conjugated polymer nanoparticle, polymers, and the like.

  17. Solid polymer electrolytes

    Science.gov (United States)

    Abraham, Kuzhikalail M.; Alamgir, Mohamed; Choe, Hyoun S.

    1995-01-01

    This invention relates to Li ion (Li.sup.+) conductive solid polymer electrolytes composed of poly(vinyl sulfone) and lithium salts, and their use in all-solid-state rechargeable lithium ion batteries. The lithium salts comprise low lattice energy lithium salts such as LiN(CF.sub.3 SO.sub.2).sub.2, LiAsF.sub.6, and LiClO.sub.4.

  18. CLASSIFICATION OF BIODEGRADABLE POLYMERS

    Directory of Open Access Journals (Sweden)

    I. I. Karpunin

    2015-01-01

    Full Text Available The executed investigations have made it possible to ascertain that a morphological structure of starch granules mainly determine technological peculiarities of starch isolation from raw material, its modification and its later use. Morphological structure of starch granules primarily depends on type of plant starch-containing raw material which has been used for its isolation. Class of raw material exerts a strong impact on the shape and size of the granules. Linear “light” amylose chains and “heavy” amylopectin branch chains form a starch granule ultrastructure. X-ray research has proved that starch granules are characterized by presence of interlacing amorphous and crystalline regions. In this case polymer orientation using stretching of the obtained end product influences on its physical and mechanical  indices which are increasing due to polymer orientation. For the purpose of packaging orientation of polymer films can solve such important problems as significant improvement of operational properties, creation of  thermosetting film materials, improvement of qualitative indices of the recycled film.Results of the conducted research have proved the fact that it is necessary to make changes in technology in order to increase biological degradability of the recycled packaging made from polymers and improve physical and mechanical indices. In this regard film production technology presupposes usage of such substances as stark and others which are characterized by rather large presence of branch chains of molecules and interlacing amorphous and crystalline regions. Such approach makes it possible to obtain after-use package which is strong and quickly degradable by micro-organisms.

  19. Dynamics of polymers

    Energy Technology Data Exchange (ETDEWEB)

    Buchenau, U [Forschungszentrum Juelich GmbH (Germany). Inst. fuer Energieverfahrenstechnik

    1996-11-01

    Neutron scattering from amorphous polymers allows to switch from incoherent to coherent scattering in the same substance. The power of the tool for the study of the picosecond dynamics of disordered matter is illustrated for polybutadiene, polycarbonate and polystyrene. The results suggest a mixture of sound waves and localized modes, strongly interacting with each other, in the picosecond range. (author) 8 figs., tabs., 39 refs.

  20. Conjugated Polymer Solar Cells

    Science.gov (United States)

    2006-05-01

    thermal gravimetry analysis (TGA)............... 12 2.6 Photoluminescence (PL) spectroscopy... gravimetry analysis (TGA) Thermal analysis of polymer films has been accomplished by TGA and DSC methods with the aid of Perkin-Elmer Series 7 Analysers...The MEH-PPV/acceptor films were prepared by spin-casting of the resulting mixture (with or without precipitate ) on glass substrates of diameter 23 mm

  1. Absorbable and biodegradable polymers

    CERN Document Server

    Shalaby, Shalaby W

    2003-01-01

    INTRODUCTION NOTES: Absorbable/Biodegradable Polymers: Technology Evolution. DEVELOPMENT AND APPLICATIONOF NEW SYSTEMS: Segmented Copolyesters with Prolonged Strength Retention Profiles. Polyaxial Crystalline Fiber-Forming Copolyester. Polyethylene Glycol-Based Copolyesters. Cyanoacrylate-Based Systems as Tissue Adhesives. Chitosan-Based Systems. Hyaluronic Acid-Based Systems. DEVELOPMENTS IN PREPARATIVE, PROCESSING, AND EVALUATION METHODS: New Approaches to the Synthesis of Crystalline. Fiber-Forming Aliphatic Copolyesters. Advances in Morphological Development to Tailor the Performance of Me

  2. Luminescent lanthanide coordination polymers

    Energy Technology Data Exchange (ETDEWEB)

    Ma, L.; Evans, O.R.; Foxman, B.M.; Lin, W.

    1999-12-13

    One-dimensional lanthanide coordination polymers with the formula Ln(isonicotinate){sub 3}(H{sub 2}O){sub 2} (Ln = Ce, Pr, Nd, Sm, Eu, Tb; 1a-f) were synthesized by treating nitrate or perchlorate salts of Ln(III) with 4-pyridinecarboxaldehyde under hydro(solvo)thermal conditions. Single-crystal and powder X-ray diffraction studies indicate that these lanthanide coordination polymers adopt two different structures. While Ce(III), Pr(III), and Nd(III) complexes adopt a chain structure with alternating Ln-(carboxylate){sub 2}-Ln and Ln-(carboxylate){sub 4}-Ln linkages, Sm(III), Eu(III), and Tb(III) complexes have a doubly carboxylate-bridged infinite-chain structure with one chelating carboxylate group on each metal center. In both structures, the lanthanide centers also bind to two water molecules to yield an eight-coordinate, square antiprismatic geometry. The pyridine nitrogen atoms of the isonicotinate groups do not coordinate to the metal centers in these lanthanide(III) complexes; instead, they direct the formation of Ln(III) coordination polymers via hydrogen bonding with coordinated water molecules. Photoluminescence measurements show that Tb(isonicotinate){sub 3}(H{sub 2}O){sub 2} is highly emissive at room temperature with a quantum yield of {approximately}90%. These results indicate that highly luminescent lanthanide coordination polymers can be assembled using a combination of coordination and hydrogen bonds. Crystal data for 1a: monoclinic space group P2{sub 1}/c, a = 9.712(2) {angstrom}, b = 19.833(4) {angstrom}, c = 11.616(2) {angstrom}, {beta} = 111.89(3){degree}, Z = 4. Crystal data for 1f: monoclinic space group C2/c, a = 20.253(4) {angstrom}, b = 11.584(2) {angstrom}, c = 9.839(2) {angstrom}, {beta} = 115.64(3){degree}, Z = 8.

  3. Mechanoresponsive Healing Polymers

    Science.gov (United States)

    Gordon, Keith L. (Inventor); Siochi, Emilie J. (Inventor)

    2018-01-01

    Methods are provided to produce new mechanoresponsive healing systems. Additionally, various embodiments provide a two tier self-healing material system concept that provides a non-intrusive method to mitigate impact damage in a structure ranging from low velocity impact damage (e.g., crack damage) to high velocity impact damage (e.g., ballistic damage.) The various embodiments provide the mechanophore linked polymer PBG-BCB-PBG. The various embodiments provide methods for synthesizing PBG-BCB-PBG.

  4. Electrochemical polymer electrolyte membranes

    CERN Document Server

    Fang, Jianhua; Wilkinson, David P

    2015-01-01

    Electrochemical Polymer Electrolyte Membranes covers PEMs from fundamentals to applications, describing their structure, properties, characterization, synthesis, and use in electrochemical energy storage and solar energy conversion technologies. Featuring chapters authored by leading experts from academia and industry, this authoritative text: Discusses cutting-edge methodologies in PEM material selection and fabricationPoints out important challenges in developing PEMs and recommends mitigation strategies to improve PEM performanceAnalyzes the cur

  5. Phyllitic minerals in hydrothermal uranium deposits. I. Crystalchemistry of relict and newly formed micas

    International Nuclear Information System (INIS)

    Leroy, Jacques; Cathelineau, Michel

    1982-01-01

    Several generations of white micas have been recognised in four two mica granite massifs which are associated with uranium deposits in the Hercynian chain. These different generations correspond to distinct geological phenomena belonging to the deuteric and hydrothermal stages of the history of these massifs. Crystalchemical studies of these micas with the aid of the electronic microprobe show that each of these phenomena corresponds a phengite of different, well defined compositions. An increase in the phengitic character and a decrease in the paragonite component are observed over time. Strong similarities exist between micas of the same generation belonging to different granite massifs. The study of the evolution of the earliest deuteric micas during later hydrothermal phenomena, mica episyenitisation and deposition of pitchblende, has shown two opposed trends. In the case of mica episyenitisation, the micas tend to reequilibrate, while in the case of pitchblende deposition and the vein stage in general, the micas preserve their primary character [fr

  6. BioArtificial polymers

    Science.gov (United States)

    Szałata, Kamila; Gumi, Tania

    2017-07-01

    Nowadays, the polymer science has impact in practically all life areas. Countless benefits coming from the usage of materials with high mechanical and chemical resistance, variety of functionalities and potentiality of modification drive to the development of new application fields. Novel approaches of combining these synthetic substances with biomolecules lead to obtain multifunctional hybrid conjugates which merge the bioactivity of natural component with outstanding properties of artificial polymer. Over the decades, an immense progress in bioartificial composites domain allowed to reach a high level of knowledge in terms of natural-like systems engineering, leading to diverse strategies of biomolecule immobilization. Together with different available options, including covalent and noncovalent attachment, come various challenges, related mainly with maintaining the biological activity of fixed molecules. Even though the amount of applications that achieve commercial status is still not substantial, and is expanding continuously in the disciplines like "smart materials," biosensors, delivery systems, nanoreactors and many others. A huge number of remarkable developments reported in the literature present a potential of bioartificial conjugates as a fabrics with highly controllable structure and multiple functionalities, serving as a powerful nanotechnological tool. This novel approach brings closer biologists, chemists and engineers, who sharing their effort and complementing the knowledge can revolutionize the field of bioartificial polymer science.

  7. La Industria Química: Importancia y Retos

    Directory of Open Access Journals (Sweden)

    Nancy Montes-Valencia

    2015-06-01

    Full Text Available La química siempre ha estado presente en la vida del hombre para satisfacer sus necesidades y mejorar su calidad de vida. Hoy en día la industria química es un importante sector industrial presente en la mayoría de países, que dinamiza el crecimiento económico, genera empleo y ofrece diversidad de productos, no obstante produce contaminación al medio ambiente y utiliza recursos naturales no renovables. Por lo tanto surge el concepto de química verde como respuesta a la problemática ambiental cuya estructura es la sostenibilidad, siendo su principal objetivo prevenir la generación de emisiones y armonizar la química con los recursos naturales. Existe un gran reto para la industria química y es encontrar fuentes alternativas de energía para no seguir dependiendo del petróleo, el gas natural y el carbón, una de estas es el uso de la biomasa para la obtención de combustibles líquidos.

  8. Polymer crowding and shape distributions in polymer-nanoparticle mixtures

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Wei Kang; Denton, Alan R., E-mail: alan.denton@ndsu.edu [Department of Physics, North Dakota State University, Fargo, North Dakota 58108-6050 (United States)

    2014-09-21

    Macromolecular crowding can influence polymer shapes, which is important for understanding the thermodynamic stability of polymer solutions and the structure and function of biopolymers (proteins, RNA, DNA) under confinement. We explore the influence of nanoparticle crowding on polymer shapes via Monte Carlo simulations and free-volume theory of a coarse-grained model of polymer-nanoparticle mixtures. Exploiting the geometry of random walks, we model polymer coils as effective penetrable ellipsoids, whose shapes fluctuate according to the probability distributions of the eigenvalues of the gyration tensor. Accounting for the entropic cost of a nanoparticle penetrating a larger polymer coil, we compute the crowding-induced shift in the shape distributions, radius of gyration, and asphericity of ideal polymers in a theta solvent. With increased nanoparticle crowding, we find that polymers become more compact (smaller, more spherical), in agreement with predictions of free-volume theory. Our approach can be easily extended to nonideal polymers in good solvents and used to model conformations of biopolymers in crowded environments.

  9. Polymer crowding and shape distributions in polymer-nanoparticle mixtures

    International Nuclear Information System (INIS)

    Lim, Wei Kang; Denton, Alan R.

    2014-01-01

    Macromolecular crowding can influence polymer shapes, which is important for understanding the thermodynamic stability of polymer solutions and the structure and function of biopolymers (proteins, RNA, DNA) under confinement. We explore the influence of nanoparticle crowding on polymer shapes via Monte Carlo simulations and free-volume theory of a coarse-grained model of polymer-nanoparticle mixtures. Exploiting the geometry of random walks, we model polymer coils as effective penetrable ellipsoids, whose shapes fluctuate according to the probability distributions of the eigenvalues of the gyration tensor. Accounting for the entropic cost of a nanoparticle penetrating a larger polymer coil, we compute the crowding-induced shift in the shape distributions, radius of gyration, and asphericity of ideal polymers in a theta solvent. With increased nanoparticle crowding, we find that polymers become more compact (smaller, more spherical), in agreement with predictions of free-volume theory. Our approach can be easily extended to nonideal polymers in good solvents and used to model conformations of biopolymers in crowded environments

  10. Synthetic approaches to uniform polymers.

    Science.gov (United States)

    Ali, Monzur; Brocchini, Steve

    2006-12-30

    Uniform polymers are characterised by a narrow molecular weight distribution (MWD). Uniformity is also defined by chemical structure in respect of (1) monomer orientation, sequence and stereo-regularity, (2) polymer shape and morphology and (3) chemical functionality. The function of natural polymers such as polypeptides and polynucleotides is related to their conformational structure (e.g. folded tertiary structure). This is only possible because of their high degree of uniformity. While completely uniform synthetic polymers are rare, polymers with broad structure and MWD are widely used in medicine and the biomedical sciences. They are integral components in final dosage forms, drug delivery systems (DDS) and in implantable devices. Increasingly uniform polymers are being used to develop more complex medicines (e.g. delivery of biopharmaceuticals, enhanced formulations or DDS's for existing actives). In addition to the function imparted by any new polymer it will be required to meet stringent specifications in terms of cost containment, scalability, biocompatibility and performance. Synthetic polymers with therapeutic activity are also being developed to exploit their polyvalent properties, which is not possible with low molecular weight molecules. There is need to utilise uniform polymers for applications where the polymer may interact with the systemic circulation, tissues or cellular environment. There are also potential applications (e.g. stimuli responsive coatings) where uniform polymers may be used for their more defined property profile. While it is not yet practical to prepare synthetic polymers to the same high degree of uniformity as proteins, nature also effectively utilises many polymers with lower degrees of uniformity (e.g. polysaccharides, poly(amino acids), polyhydroxyalkanoates). In recent years it has become possible to prepare with practical experimental protocols sufficient quantities of polymers that display many aspects of uniformity. This

  11. Biomolecule-functionalized polymer brushes.

    Science.gov (United States)

    Jiang, Hui; Xu, Fu-Jian

    2013-04-21

    Functional polymer brushes have been utilized extensively for the immobilization of biomolecules, which is of crucial importance for the development of biosensors and biotechnology. Recent progress in polymerization methods, in particular surface-initiated atom transfer radical polymerization (ATRP), has provided a unique means for the design and synthesis of new biomolecule-functionalized polymer brushes. This current review summarizes such recent research activities. The different preparation strategies for biomolecule immobilization through polymer brush spacers are described in detail. The functional groups of the polymer brushes used for biomolecule immobilization include epoxide, carboxylic acid, hydroxyl, aldehyde, and amine groups. The recent research activities indicate that functional polymer brushes become versatile and powerful spacers for immobilization of various biomolecules to maximize their functionalities. This review also demonstrates that surface-initiated ATRP is used more frequently than other polymerization methods in the designs of new biomolecule-functionalized polymer brushes.

  12. Claisen thermally rearranged (CTR) polymers

    Science.gov (United States)

    Tena, Alberto; Rangou, Sofia; Shishatskiy, Sergey; Filiz, Volkan; Abetz, Volker

    2016-01-01

    Thermally rearranged (TR) polymers, which are considered the next-generation of membrane materials because of their excellent transport properties and high thermal and chemical stability, are proven to have significant drawbacks because of the high temperature required for the rearrangement and low degree of conversion during this process. We demonstrate that using a [3,3]-sigmatropic rearrangement, the temperature required for the rearrangement of a solid glassy polymer was reduced by 200°C. Conversions of functionalized polyimide to polybenzoxazole of more than 97% were achieved. These highly mechanically stable polymers were almost five times more permeable and had more than two times higher degrees of conversion than the reference polymer treated under the same conditions. Properties of these second-generation TR polymers provide the possibility of preparing efficient polymer membranes in a form of, for example, thin-film composite membranes for various gas and liquid membrane separation applications. PMID:27482538

  13. Terminology of Polymers Containing Ionizable or Ionic Groups and of Polymers Containing Ions, VII.3

    Directory of Open Access Journals (Sweden)

    Jarm, V.

    2009-10-01

    Full Text Available The class of ionic polymers has widespread application in many areas of everyday life, in industrial production, and in the processes of living matter. The properties of ionic polymers depend on the polymer structure, and the nature, content, and location of the ionic groups. To clear differences among various ionic polymers, the IUPAC recommendations present 34 definitionsfor the ionomer, polyacid, polybase, polyampholytic polymer, ion-exchange polymer, polybetaine, polyelectrolyte, intrinsically conducting polymer, solid polymer electrolyte, etc

  14. Moraceae endémicas del Perú

    Directory of Open Access Journals (Sweden)

    Pamela Cáceres

    2013-10-01

    Full Text Available La familia Moraceae es reconocida en el Perú por presentar 19 géneros y 128 especies (Brako & Zarucchi, 1993; Ulloa Ulloa et al., 2004, la mayoría arbóreas y/o hemiepífitos. En este trabajo reconocemos dos especies endémicas en igual número de géneros. Las especies endémicas se encuentran en la región Bosques Húmedos Amazónicos, entre los 115 y 220 m de altitud. Ambas especies endémicas se encuentran dentro del Sistema Nacional de Áreas Naturales Protegidas por el Estado.

  15. Onagraceae endémicas del Perú

    Directory of Open Access Journals (Sweden)

    Susy Castillo

    2013-10-01

    Full Text Available Esta es la familia de las «fucsias», la cual es reconocida en el Perú por presentar seis géneros y 76 especies (Brako & Zarucchi, 1993; Ulloa Ulloa et al., 2004, principalmente arbustos y hierbas. En este trabajo reconocemos 24 especies endémicas, la mayoría en el género Fuchsia. Las especies endémicas se encuentran mayormente en la región Bosques Muy Húmedos Montanos, entre los 1600 y 2500 m de altitud. Diez especies endémicas se encuentran representados dentro del Sistema Nacional de Áreas Naturales Protegidas por el Estado.

  16. Gentianaceae endémicas del Perú

    Directory of Open Access Journals (Sweden)

    Susy Castillo

    2013-10-01

    Full Text Available La familia Gentianaceae es reconocida en el Perú por presentar alrededor de 15 géneros y aproximadamente de 170 especies (Brako & Zarucchi, 1993; Ulloa Ulloa et al., 2004; S. Castillo, com.pers., mayormente hierbas y arbustos. En este trabajo se reconoce 103 especies endémicas en siete géneros. Los géneros con mayor número de especies endemicas son Gentianella y Macrocarpaea. Las especies endémicas ocupan principalmente las regiones de la Puna Húmeda y Seca, Páramo y Bosque Muy Húmedo Montano, entre los 1000 y 5100 m de altitud. Se aplicaron las categorías y criterios de la UICN a 99 especies. Treinta y tres especies endémicas se encuentran representadas dentro de un área protegida.

  17. Relaciones económicas bilaterales entre Ecuador y Brasil

    OpenAIRE

    Herrera Díaz, Stefany Natalie

    2015-01-01

    Dentro de la dinámica mundial actual, resulta de especial interés para Ecuador el análisis de sus relaciones económicas bilaterales con Brasil, debido al papel protagónico que ha alcanzado este país tanto a nivel regional como mundial. A nivel regional, varios de los países vecinos han delineado, incluso, su política exterior en función de potenciar sus relaciones políticas y económicas con él, y a nivel internacional, su participación en la geopolítica mundial es cada vez mayor. En términos ...

  18. Solid polymer electrolyte lithium batteries

    Science.gov (United States)

    Alamgir, Mohamed; Abraham, Kuzhikalail M.

    1993-01-01

    This invention pertains to Lithium batteries using Li ion (Li.sup.+) conductive solid polymer electrolytes composed of solvates of Li salts immobilized in a solid organic polymer matrix. In particular, this invention relates to Li batteries using solid polymer electrolytes derived by immobilizing solvates formed between a Li salt and an aprotic organic solvent (or mixture of such solvents) in poly(vinyl chloride).

  19. Vacuum ultraviolet photochemistry of polymers

    International Nuclear Information System (INIS)

    Skurat, Vladimir

    2003-01-01

    The interaction of vacuum UV radiation (wavelength range from 1 to 200 nm) with polymers is interesting for fundamental and applied sciences. This interest is stimulated by various reasons: - Wide applications of polymeric materials in semiconductor technology, where they are used as photoresist materials in combination with VUV light sources (lasers, excimer lamps, synchrotron radiation and others). - Polymers are widely used as spacecraft materials in the last 20 years. On near-Earth orbits, the polymeric materials of spacecraft surfaces are destroyed by solar radiation. - VUV radiation is one of the components of gas discharge plasmas, which are used for treatment of polymer, with the aim of modifying their surface properties. The main features of interaction of VUV radiation with polymers are discussed. The spectra of intrinsic absorption of saturated polymers (polyethylene, polypropylene, polytetrafluoroethylene and others) are situated mainly in the VUV region. The photochemistry of polymers in the VUV region is very different from their photochemistry at wavelengths longer than 200 nm, where the absorption spectra belong to impurities and polymer defects. The polymer photochemistry in the VUV region is wavelength-dependent. At wavelengths longer than about 140 nm, the main role is played by transformations of primary-formed singlet excited molecules. At shorter wavelengths the role of photoionization increases progressively and the main features of VUV photolysis become similar to the picture of radiolysis, with significant contributions of charge pairs and triplet excited molecules. Very important features of VUV light absorption in polymers are high absorption coefficients. Because of this, the surface layers absorb large doses of energy. This leads to very profound transformation of material on the polymer surface. In particular for polymers which are considered destroyed by radiation (for example, perfluoropolymers), this leads to VUV-induced erosion

  20. Planar-Processed Polymer Transistors.

    Science.gov (United States)

    Xu, Yong; Sun, Huabin; Shin, Eul-Yong; Lin, Yen-Fu; Li, Wenwu; Noh, Yong-Young

    2016-10-01

    Planar-processed polymer transistors are proposed where the effective charge injection and the split unipolar charge transport are all on the top surface of the polymer film, showing ideal device characteristics with unparalleled performance. This technique provides a great solution to the problem of fabrication limitations, the ambiguous operating principle, and the performance improvements in practical applications of conjugated-polymer transistors. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Conjugated Polymers for Energy Production

    DEFF Research Database (Denmark)

    Livi, Francesco

    This dissertation is aimed at developing materials for flexible, large area, ITO-free polymer solar cells (PSCs) fully printed under ambient conditions. A large screening of conjugated polymers, both novel and well-known materials, has been carried out in order to find suitable candidates...... polymerization method for industrial production of polymers. Several DArP protocols have been employed for the synthesis of PPDTBT leading to polymers with high structural regularity and photovoltaic performances comparable with the same materials synthesized via Stille cross-coupling polymerization...

  2. Multifunctional Polymer/Inorganic Nanocomposites

    National Research Council Canada - National Science Library

    Manias, E

    2003-01-01

    ... in multifunctional nanocomposite materials. Understanding the structure/property relations in polymer/clay nanocomposites is of great importance in designing materials with desired sets of properties...

  3. Wear of polymers and composites

    CERN Document Server

    Abdelbary, Ahmed

    2015-01-01

    In the field of tribology, the wear behaviour of polymers and composite materials is considered a highly non-linear phenomenon. Wear of Polymers and Composites introduces fundamentals of polymers and composites tribology. The book suggests a new approach to explore the effect of applied load and surface defects on the fatigue wear behaviour of polymers, using a new tribometer and thorough experiments. It discusses effects of surface cracks, under different static and cyclic loading parameters on wear, and presents an intelligent algorithm, in the form of a neural network, to map the relations

  4. Application of Composite Polymer Electrolytes

    National Research Council Canada - National Science Library

    Scrosati, Bruno

    2001-01-01

    ...)PEO-based composite polymer electrolytes, by a series of specifically addressed electrochemical tests which included the determination of the conductivity and of the lithium transference number...

  5. Sustainable polymers from renewable resources.

    Science.gov (United States)

    Zhu, Yunqing; Romain, Charles; Williams, Charlotte K

    2016-12-14

    Renewable resources are used increasingly in the production of polymers. In particular, monomers such as carbon dioxide, terpenes, vegetable oils and carbohydrates can be used as feedstocks for the manufacture of a variety of sustainable materials and products, including elastomers, plastics, hydrogels, flexible electronics, resins, engineering polymers and composites. Efficient catalysis is required to produce monomers, to facilitate selective polymerizations and to enable recycling or upcycling of waste materials. There are opportunities to use such sustainable polymers in both high-value areas and in basic applications such as packaging. Life-cycle assessment can be used to quantify the environmental benefits of sustainable polymers.

  6. Phenomenology of polymer solution dynamics

    National Research Council Canada - National Science Library

    Phillies, George D. J

    2011-01-01

    ... solutions, not dilute solutions or polymer melts. From centrifugation and solvent dynamics to viscosity and diffusion, experimental measurements and their quantitative representations are the core of the discussion...

  7. Small angle scattering and polymers

    International Nuclear Information System (INIS)

    Cotton, J.P.

    1996-01-01

    The determination of polymer structure is a problem of interest for both statistical physics and industrial applications. The average polymer structure is defined. Then, it is shown why small angle scattering, associated with isotopic substitution, is very well suited to the measurement of the chain conformation. The corresponding example is the old, but pedagogic, measurement of the chain form factor in the polymer melt. The powerful contrast variation method is illustrated by a recent determination of the concentration profile of a polymer interface. (author) 12 figs., 48 refs

  8. Polymer Processing and Characterization Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — The purpose is to process and evaluate polymers for use in nonlinear optical, conductive and structural Air Force applications. Primary capabilities are extrusion of...

  9. Funciones Económicas en un Entorno Incierto

    OpenAIRE

    Lazzari, Luisa L; Chiodi, Jorge A; Moulia, Patricia I

    2015-01-01

    El mundo está atravesando una de las crisis económicas más profundas de los últimos tiempos. Los escenarios actuales y futuros están plagados de incertidumbre que, en general, no se considera en el análisis de las distintas funciones económicas de interés para el desarrollo del negocio, y la realidad se representa mediante modelos estáticos y casi perfectos del comportamiento de los mercados. La teoría de conjuntos borrosos permite construir modelos adecuados a partir de realidades inciertas ...

  10. PLACAS CERÂMICAS - UMA INTRODUÇÃO

    Directory of Open Access Journals (Sweden)

    Carlos Maurício F. Vieira

    2010-05-01

    Full Text Available Este trabalho tem por objetivo apresentar uma revisão geral sobre as principais características exigidas para a obtenção de placas cerâmicas (pisos e revestimentos. As principais rotas de processamento são discutidas. Dados de mercado são apresentados com a finalidade de mostrar a importância e a situação atual da indústria cerâmica nacional no setor de pisos e revestimentos.

  11. Scrophulariaceae endémicas del Perú

    Directory of Open Access Journals (Sweden)

    Blanca León

    2013-10-01

    Full Text Available La familia Scrophulariaceae es reconocida en el Perú por presentar alrededor de 18 géneros y 35 especies (Brako & Zarucchi, 1993; Ulloa Ulloa et al., 2004, principalmente herbáceas. En este trabajo reconocemos dos especies endémicas en dos géneros, las cuales se encuentran principalmente en la región Bosques Húmedos Amazónicos, entre los 200 y 1000 m de altitud. Ninguna de las especies endémicas se encuentra representada dentro del Sistema Nacional de Áreas Naturales Protegidas por el Estado.

  12. Experiencias divertidas de electroquímica casera

    OpenAIRE

    Santiago Heredia-Avalos

    2007-01-01

    La química, dentro de la cual se incluye la electroquímica, es una materia que los estudiantes suelen ver como complicada, aburrida, carente de interés y que, además requiere de material de laboratorio sofisticado y reactivos químicos inaccesibles. Nada más lejos de la realidad, tal y como se pondrá de manifiesto en este trabajo, donde se proponen varias experiencias sencillas usando sustancias baratas, la mayoría de las cuales pueden encontrarse en un supermercado, y utensilio...

  13. Oleaceae endémicas del Perú

    Directory of Open Access Journals (Sweden)

    Isidoro Sánchez

    2013-10-01

    Full Text Available La familia Oleaceae es reconocida en el Perú por presentar seis géneros y 13 especies (Brako & Zarucchi, 1993, la mayoría árboles. En este trabajo reconocemos dos especies endémicas en igual número de géneros. Las especies endémicas han sido encontradas en las regiones Matorral Desértico y Bosques Húmedos Amazónicos, entre los 250 y 1850 m de altitud. Ambas especies se encuentran dentro del Sistema Nacional de Áreas Naturales Protegidas por el Estado.

  14. Clickable antifouling polymer brushes for polymer pen lithography

    Czech Academy of Sciences Publication Activity Database

    Bog, U.; de los Santos Pereira, Andres; Mueller, S. L.; Havenridge, S.; Parrillo, Viviana; Bruns, M.; Holmes, A. E.; Rodriguez-Emmenegger, C.; Fuchs, H.; Hirtz, M.

    2017-01-01

    Roč. 9, č. 13 (2017), s. 12109-12117 ISSN 1944-8244 R&D Projects: GA ČR(CZ) GJ15-09368Y Institutional support: RVO:61389013 Keywords : antifouling * biofunctional interfaces * polymer brushes Subject RIV: CD - Macromolecular Chemistry OBOR OECD: Polymer science Impact factor: 7.504, year: 2016

  15. Enhancement of Polymer Cytocompatibility by Nanostructuring of Polymer Surface

    Czech Academy of Sciences Publication Activity Database

    Slepička, P.; Kasálková-Slepičková, N.; Bačáková, Lucie; Kolská, Z.; Švorčík, V.

    2012-01-01

    Roč. 2012, č. 2012 (2012), ID527403 ISSN 1687-4110 R&D Projects: GA ČR(CZ) GBP108/12/G108 Institutional support: RVO:67985823 Keywords : polymer cytocompatibility * polymer surface * nanotechnology Subject RIV: EI - Biotechnology ; Bionics Impact factor: 1.547, year: 2012

  16. Radiation Synthesis of Superabsorbent Polymers Based on Natural Polymers

    International Nuclear Information System (INIS)

    Sen, Murat; Hayrabolulu, Hande

    2010-01-01

    The objectives of proposed research contract were first synthesize superabsorbent polymers based on natural polymers to be used as disposable diapers and soil conditioning materials in agriculture, horticulture and other super adsorbent using industries. We have planned to use the natural polymers; locust beam gum, tara gum, guar gum and sodium alginate on the preparation of natural superabsorbent polymers(SAP). The aqueous solution of natural polymers and their blends with trace amount of monomer and cross-linking agents will be irradiated in paste like conditions by gamma rays for the preparation of cross-linked superabsorbent systems. The water absorption and deswellling capacity of prepared super adsorbents and retention capacity, absorbency under load, suction power, swelling pressure and pet-rewet properties will be determined. Use of these materials instead of synthetic super absorbents will be examined by comparing the performance of finished products. The experimental studies achieved in the second year of project mainly on the effect of radiation on the chemistry of sodium alginate polymers in different irradiation conditions and structure-property relationship particularly with respect to radiation induced changes on the molecular weight of natural polymers and preliminary studies on the synthesis of natural-synthetic hydride super adsorbent polymers were given in details

  17. Polymer Crowding in Confined Polymer-Nanoparticle Mixtures

    Science.gov (United States)

    Davis, Wyatt J.; Denton, Alan R.

    Crowding can influence the conformations and thus functionality of macromolecules in quasi-two-dimensional environments, such as DNA or proteins confined to a cell membrane. We explore such crowding within a model of polymers as penetrable ellipses, whose shapes are governed by the statistics of a 2D random walk. The principal radii of the polymers fluctuate according to probability distributions of the eigenvalues of the gyration tensor. Within this coarse-grained model, we perform Monte Carlo simulations of mixtures of polymers and hard nanodisks, including trial changes in polymer conformation (shape and orientation). Penetration of polymers by nanodisks is incorporated with a free energy cost predicted by polymer field theory. Over ranges of size ratio and nanodisk density, we analyze the influence of crowding on polymer shape by computing eigenvalue distributions, mean radius of gyration, and mean asphericity of the polymer. We compare results with predictions of free-volume theory and with corresponding results in three dimensions. Our approach may help to interpret recent (and motivate future) experimental studies of biopolymers interacting with cell membranes, with relevance for drug delivery and gene therapy. This work was supported by the National Science Foundation under Grant No. DMR-1106331.

  18. Polymer solidification national program

    International Nuclear Information System (INIS)

    Kalb, P.D.; Colombo, P.

    1993-04-01

    Brookhaven National Laboratory (BNL) has developed several new and innovative polymer processes for the solidification of low-level radioactive, hazardous and mixed wastes streams. Polyethylene and modified sulfur cement solidification technologies have undergone steady, gradual development at BNL over the past nine years. During this time they have progressed through each of the stages necessary for logical technology maturation: from process conception, parameter optimization, waste form testing, evaluation of long-term durability, economic analysis, and scale-up feasibility. This technology development represents a significant investment which can potentially provide DOE with both short- and long-term savings

  19. Monte Carlo simulations of confined polymer systems

    NARCIS (Netherlands)

    Vliet, Johannes Henricus van

    1991-01-01

    This thesis considers confined polymer systems. These systems are of considerable interest, e.g., thin polymer films, chromotography of polymer solutions, drag reduction, enhanced oil recovery, stabilization of colloidal dispersions, lubrication and biolubrication. The method used to study these

  20. Processing of polymers using reactive solvents

    NARCIS (Netherlands)

    Lemstra, P.J.; Kurja, J.; Meijer, H.E.H.; Meijer, H.E.H.

    1997-01-01

    A review with many refs. on processing of polymers using reactive solvents including classification of synthetic polymers, guidelines for the selection of reactive solvents, basic aspects of processing, examples of intractable and tractable polymer/reactive solvent system