WorldWideScience

Sample records for mgs science sampler

  1. Accelerated Adaptive MGS Phase Retrieval

    Science.gov (United States)

    Lam, Raymond K.; Ohara, Catherine M.; Green, Joseph J.; Bikkannavar, Siddarayappa A.; Basinger, Scott A.; Redding, David C.; Shi, Fang

    2011-01-01

    The Modified Gerchberg-Saxton (MGS) algorithm is an image-based wavefront-sensing method that can turn any science instrument focal plane into a wavefront sensor. MGS characterizes optical systems by estimating the wavefront errors in the exit pupil using only intensity images of a star or other point source of light. This innovative implementation of MGS significantly accelerates the MGS phase retrieval algorithm by using stream-processing hardware on conventional graphics cards. Stream processing is a relatively new, yet powerful, paradigm to allow parallel processing of certain applications that apply single instructions to multiple data (SIMD). These stream processors are designed specifically to support large-scale parallel computing on a single graphics chip. Computationally intensive algorithms, such as the Fast Fourier Transform (FFT), are particularly well suited for this computing environment. This high-speed version of MGS exploits commercially available hardware to accomplish the same objective in a fraction of the original time. The exploit involves performing matrix calculations in nVidia graphic cards. The graphical processor unit (GPU) is hardware that is specialized for computationally intensive, highly parallel computation. From the software perspective, a parallel programming model is used, called CUDA, to transparently scale multicore parallelism in hardware. This technology gives computationally intensive applications access to the processing power of the nVidia GPUs through a C/C++ programming interface. The AAMGS (Accelerated Adaptive MGS) software takes advantage of these advanced technologies, to accelerate the optical phase error characterization. With a single PC that contains four nVidia GTX-280 graphic cards, the new implementation can process four images simultaneously to produce a JWST (James Webb Space Telescope) wavefront measurement 60 times faster than the previous code.

  2. The Gravity Field of Mars From MGS, Mars Odyssey, and MRO Radio Science

    Science.gov (United States)

    Genova, Antonio; Goossens, Sander; Lemoine, Frank G.; Mazarico, Erwan; Smith, David E.; Zuber, Maria T.

    2015-01-01

    The Mars Global Surveyor (MGS), Mars Odyssey (ODY), and Mars Reconnaissance Orbiter (MRO) missions have enabled NASA to conduct reconnaissance and exploration of Mars from orbit for sixteen consecutive years. These radio systems on these spacecraft enabled radio science in orbit around Mars to improve the knowledge of the static structure of the Martian gravitational field. The continuity of the radio tracking data, which cover more than a solar cycle, also provides useful information to characterize the temporal variability of the gravity field, relevant to the planet's internal dynamics and the structure and dynamics of the atmosphere [1]. MGS operated for more than 7 years, between 1999 and 2006, in a frozen sun-synchronous, near-circular, polar orbit with the periapsis at approximately 370 km altitude. ODY and MRO have been orbiting Mars in two separate sun-synchronous orbits at different local times and altitudes. ODY began its mapping phase in 2002 with the periapis at approximately 390 km altitude and 4-5pm Local Solar Time (LST), whereas the MRO science mission started in November 2006 with the periapis at approximately 255 km altitude and 3pm LST. The 16 years of radio tracking data provide useful information on the atmospheric density in the Martian upper atmosphere. We used ODY and MRO radio data to recover the long-term periodicity of the major atmospheric constituents -- CO2, O, and He -- at the orbit altitudes of these two spacecraft [2]. The improved atmospheric model provides a better prediction of the annual and semi-annual variability of the dominant species. Therefore, the inclusion of the recovered model leads to improved orbit determination and an improved gravity field model of Mars with MGS, ODY, and MRO radio tracking data.

  3. MGS Esmeralda: new large seed mungbean cultivar MGS Esmeralda: nova cultivar de mungo-verde de sementes grandes

    Directory of Open Access Journals (Sweden)

    Rogério Faria Vieira

    2008-06-01

    Full Text Available Mungbean cultivar MGS Esmeralda was developed by Asian Vegetable Research and Development Center (Shanhua, Taiwan, as a result of crossing between the lines VC 1973A and VC 2768A. In ten trials conducted in the State of Minas Gerais, Brazil, it produced 13.5% more grains than 'Ouro Verde MG-2' (control cultivar, and its highest yield was 2,550 kg ha-1. The cultivar MGS Esmeralda is more susceptible to lodging, and its pods mature more uniformly than Ouro Verde MG-2 pods. One hundred-seed mass of 'MGS Esmeralda' ranged between 5.5 and 6.8 g. Both cultivars are susceptible to powdery mildew and cercospora leaf spot.A cultivar de mungo-verde MGS Esmeralda foi criada pelo Asian Vegetable Research and Development Center, localizado em Shanhua, Formosa. Ela é resultado do cruzamento entre as linhagens VC 1973A e VC 2768A. Em dez ensaios conduzidos em Minas Gerais, ela produziu 13,5% mais grãos do que a cultivar Ouro Verde MG-2 (testemunha, e sua produtividade mais alta foi 2.550 kg ha-1. A cultivar MGS Esmeralda é mais suscetível ao acamamento do que a Ouro Verde MG-2, mas suas vagens amadurecem mais uniformemente. A massa de 100 grãos da 'MGS Esmeralda' varia de 5,5 a 6,8 g. Ambas as cultivares são suscetíveis ao oídio e à cercosporiose.

  4. Passive samplers and community science in regional air quality measurement, education and communication

    International Nuclear Information System (INIS)

    DeForest Hauser, Cindy; Buckley, Alexandra; Porter, Juliana

    2015-01-01

    Charlotte, in Mecklenburg County, North Carolina, was ranked in the top ten cities with the worst air quality for ozone in the United States by the American Lung Association from 2009 to 2011. Nearby counties that may experience similar air quality do not have state or county monitors. This study utilized NO x and ozone Ogawa passive samplers and community scientists to monitor air quality in five counties surrounding Charlotte and increase public engagement in air quality issues. Community scientists deployed samplers weekly at a residential site within each county. Samples were analyzed using spectrophotometry and ion chromatography. Elevated NO x concentrations were observed in four of the five counties relative to those with existing monitors. Ozone concentrations showed little county to county variation, except Iredell and Cabarrus which had higher concentrations than Rowan. Community involvement in this work led to an increase in local dissemination of the results, thus increasing air quality awareness. - Highlights: • NO x concentrations in four adjacent counties were higher than the Mecklenburg site. • Ozone concentrations showed little county to county variation. • Passive samplers and community science can extend the air quality monitoring network. • Community science increases community awareness of air quality issues. - Regional community air quality monitoring is important in educating communities about air quality science issues that can impact personal health and behavior

  5. Sampler bias -- Phase 1

    International Nuclear Information System (INIS)

    Blanchard, R.J.

    1995-01-01

    This documents Phase 1 determinations on sampler induced bias for four sampler types used in tank characterization. Each sampler, grab sampler or bottle-on-a-string, auger sampler, sludge sampler and universal sampler, is briefly discussed and their physical limits noted. Phase 2 of this document will define additional testing and analysis to further define Sampler Bias

  6. A Novel synthesis of MgS and its application as electrode material for lithium-ion batteries

    International Nuclear Information System (INIS)

    Wang, Minjuan; Li, Xiang; Gao, Mingxia; Pan, Hongge; Liu, Yongfeng

    2014-01-01

    Highlights: • Nanocrystallite MgS was synthesized by means of a reaction of MgH 2 of S via ball milling. • MgS was firstly investigated as anode material for lithium-ion batteries (LIBs). • MgS with acetylene black introduced by ball milling shows superior electrochemical property. • The mechanisms of the lithium insertion and extraction processes of MgS are discussed. • The work is considered helpful in developing new electrode material for LIBs. - Abstract: MgS was firstly investigated as an anode material for lithium-ion batteries (LIBs). A novel method for the synthesis of nano-sized MgS was conducted, i.e., by means of a reaction of MgH 2 of S via ball milling. Acetylene black (AB) was used as electron conductive agent and introduced by two approaches to the MgS anode material: the one is ball milling AB with the as-prepared MgS derived from MgH 2 and S; the other is pre-milling AB with S and then further milling the mixture with MgH 2 . X-ray diffraction, scanning electron microscopy, transmission electron microscopy (TEM) and high resolution TEM analyses show that MgS/AB composites with MgS nanocrystallites embedded in the AB matrix are formed via either of the approaches. The MgS anode derived from MgH 2 and the pre-milled S/AB mixture shows high capacity. Capacity fading occurs mainly in the initial several cycles. A capacity of 630 mA h/g is retained after 80 cycles. The electrochemical property is much better than that of the MgS/AB derived from MgS and AB, due to the much homogenous microstructure of the former. The mechanism of the lithium insertion and extraction process of MgS is primarily discussed. The work is considered helpful in developing new synthesis method for MgS and new electrode material for LIBs

  7. A mathematics sampler topics for the liberal arts

    CERN Document Server

    Berlinghoff, William P; Skrien, Dale

    2001-01-01

    Now in its fifth edition, A Mathematics Sampler presents mathematics as both science and art, focusing on the historical role of mathematics in our culture. It uses selected topics from modern mathematics-including computers, perfect numbers, and four-dimensional geometry-to exemplify the distinctive features of mathematics as an intellectual endeavor, a problem-solving tool, and a way of thinking about the rapidly changing world in which we live. A Mathematics Sampler also includes unique LINK sections throughout the book, each of which connects mathematical concepts with areas of interest th

  8. Determination of the maximum MGS mounting height : phase II detailed analysis with LS-DYNA.

    Science.gov (United States)

    2012-12-01

    Determination of the maximum Midwest Guardrail System (MGS) mounting height was performed in two phases. : Phase I concentrated on crash testing: two full-scale crash tests were performed on the MGS with top-rail mounting heights : of 34 in. (864 mm)...

  9. Chemical and toxicologic assessment of organic contaminants in surface water using passive samplers

    Science.gov (United States)

    Alvarez, D.A.; Cranor, W.L.; Perkins, S.D.; Clark, R.C.; Smith, S.B.

    2008-01-01

    Passive sampling methodologies were used to conduct a chemical and toxicologic assessment of organic contaminants in the surface waters of three geographically distinct agricultural watersheds. A selection of current-use agrochemicals and persistent organic pollutants, including polycyclic aromatic hydrocarbons, polychlorinated biphenyls, and organochlorine pesticides, were targeted using the polar organic chemical integrative sampler (POCIS) and the semipermeable membrane device passive samplers. In addition to the chemical analysis, the Microtox assay for acute toxicity and the yeast estrogen screen (YES) were conducted as potential assessment tools in combination with the passive samplers. During the spring of 2004, the passive samplers were deployed for 29 to 65 d at Leary Weber Ditch, IN; Morgan Creek, MD; and DR2 Drain, WA. Chemical analysis of the sampler extracts identified the agrochemicals predominantly used in those areas, including atrazine, simazine, acetochlor, and metolachlor. Other chemicals identified included deethylatrazine and deisopropylatrazine, trifluralin, fluoranthene, pyrene, cis- and trans-nonachlor, and pentachloroanisole. Screening using Microtox resulted in no acutely toxic samples. POCIS samples screened by the YES assay failed to elicit a positive estrogenic response. Copyright ?? 2008 by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America. All rights reserved.

  10. Observational evidence for composite grains in an AGB outflow: MgS in the extreme carbon star LL Pegasi

    NARCIS (Netherlands)

    Lombaert, R.; de Vries, B.L.; de Koter, A.; Decin, L.; Min, M.; Smolders, K.; Mutschke, H.; Waters, L.B.F.M.

    2012-01-01

    The broad 30 μm feature in carbon stars is commonly attributed to MgS dust particles. However, reproducing the 30 μm feature with homogeneous MgS grains would require much more sulfur relative to the solar abundance. Direct gas-phase condensation of MgS occurs at a low efficiency. Precipitation of

  11. Indoor Sampler Siting

    Energy Technology Data Exchange (ETDEWEB)

    Sohn, Michael D.; Lorenzetti, David M.

    2009-03-01

    Contaminant releases in or near a building can lead to significant human exposures unless prompt response is taken. U.S. Federal and local agencies are implementing programs to place air-monitoring samplers in buildings to quickly detect biological agents. We describe a probabilistic algorithm for siting samplers in order to detect accidental or intentional releases of biological material. The algorithm maximizes the probability of detecting a release from among a suite of realistic scenarios. The scenarios may differ in any unknown, for example the release size or location, weather, mode of building operation, etc. The algorithm also can optimize sampler placement in the face of modeling uncertainties, for example the airflow leakage characteristics of the building, and the detection capabilities of the samplers. In an illustrative example, we apply the algorithm to a hypothetical 24-room commercial building, finding optimal networks for a variety of assumed sampler types and performance characteristics. We also discuss extensions of this work for detecting ambient pollutants in buildings, and for understanding building-wide airflow, pollutant dispersion, and exposures.

  12. MGS Radio Science Measurements of Atmospheric Dynamics on Mars

    Science.gov (United States)

    Hinson, D. P.

    2001-12-01

    The Sun-synchronous, polar orbit of Mars Global Surveyor (MGS) provides frequent opportunities for radio occultation sounding of the neutral atmosphere. The basic result of each experiment is a profile of pressure and temperature versus planetocentric radius and geopotential. More than 4000 profiles were obtained during the 687-day mapping phase of the mission, and additional observations are underway. These measurements allow detailed characterization of planetary-scale dynamics, including stationary planetary (or Rossby) waves and transient waves produced by instability. For example, both types of dynamics were observed near 67° S during midwinter of the southern hemisphere (Ls=134° --160° ). Planetary waves are the most prominent dynamical feature in this subset of data. At zonal wave number s=1, both the temperature and geopotential fields tilt westward with increasing height, as expected for vertically-propagating planetary waves forced at the surface. The wave-2 structure is more nearly barotropic. The amplitude in geopotential height at Ls=150° increases from ~200 m near the surface to ~700 m at 10 Pa. The corresponding meridional wind speed increases from ~5 m s-1 near the surface to ~20 m s-1 at 10 Pa. Traveling ``baroclinic'' waves also appear intermittently during this interval. The dominant mode has a period of ~2 sols, s=3, and a peak amplitude of ~7 K at 300 Pa. Stong zonal variations in eddy amplitude signal the presence of a possible ``storm zone'' at 150° --330° E longitude. This talk will include other examples of these phenomena as well as comparisons with computer simulations by a Martian general circulation model (MGCM).

  13. Indigenous high volume air sampler

    International Nuclear Information System (INIS)

    Kotrappa, P.; Setty, N.P.N.; Raghunath, B.; Sivasubrahmanyam, P.S.

    1978-01-01

    A high volume air sampler for use in assessing concentrations of low levels of air borne particulates has been fabricated. The sampler will be of use in radioactive installations, conventional industries and environmental pollution analysis. It is comparable in performance with the imported Staplex air samplers. A turbine and motor system similar to the one found in conventional vacuum cleaners is used in its design. The sampler units can be produced in large numbers. (M.G.B.)

  14. Triadic split-merge sampler

    Science.gov (United States)

    van Rossum, Anne C.; Lin, Hai Xiang; Dubbeldam, Johan; van der Herik, H. Jaap

    2018-04-01

    In machine vision typical heuristic methods to extract parameterized objects out of raw data points are the Hough transform and RANSAC. Bayesian models carry the promise to optimally extract such parameterized objects given a correct definition of the model and the type of noise at hand. A category of solvers for Bayesian models are Markov chain Monte Carlo methods. Naive implementations of MCMC methods suffer from slow convergence in machine vision due to the complexity of the parameter space. Towards this blocked Gibbs and split-merge samplers have been developed that assign multiple data points to clusters at once. In this paper we introduce a new split-merge sampler, the triadic split-merge sampler, that perform steps between two and three randomly chosen clusters. This has two advantages. First, it reduces the asymmetry between the split and merge steps. Second, it is able to propose a new cluster that is composed out of data points from two different clusters. Both advantages speed up convergence which we demonstrate on a line extraction problem. We show that the triadic split-merge sampler outperforms the conventional split-merge sampler. Although this new MCMC sampler is demonstrated in this machine vision context, its application extend to the very general domain of statistical inference.

  15. Introduction to SamplerCompare

    Directory of Open Access Journals (Sweden)

    Madeleine B. Thompson

    2011-08-01

    Full Text Available SamplerCompare is an R package for comparing the performance of Markov chain Monte Carlo (MCMC samplers. It samples from a collection of distributions with a collection of MCMC methods over a range of tuning parameters. Then, using log density evaluations per uncorrelated observation as a figure of merit, it generates a grid of plots showing the results of the simulation. It comes with a collection of predefined distributions and samplers and provides R and C interfaces for defining additional ones. It also provides the means to import simulation data generated by external systems. This document provides background on the package and demonstrates the basics of running simulations, visualizing results, and defining distributions and samplers in R.

  16. MGS Radio Science Electron Density Profiles: Interannual Variability and Implications for the Martian Neutral Atmosphere

    Science.gov (United States)

    Bougher, S. W.; Engel, S.; Hinson, D. P.; Murphy, J. R.

    2004-01-01

    Martian electron density profiles provided by the Mars Global Surveyor (MGS) Radio Science (RS) experiment over the 95-200 km altitude range indicate what the height of the electron peak and the longitudinal structure of the peak height are sensitive indicators of the physical state of the Mars lower and upper atmospheres. The present analysis is carried out on five sets of occultation profiles, all at high solar zenith angles (SZA). Variations spanning 2 Martian years are investigated near aphelion conditions at high northern latitudes (64.7 - 77.6 N) making use of four of these data sets. A mean ionospheric peak height of 133.5 - 135 km is obtained near SZA = 78 - 82 deg.; a corresponding mean peak density of 7.3 - 8.5 x l0(exp 4)/ qu cm is also measured during solar moderate conditions at Mars. Strong wave number 2 - 3 oscillations in peak heights are consistently observed as a function of longitude over the 2 Martian years. These observed ionospheric features are remarkably similar during aphelion conditions 1 Martian year apart. This year-to-year repeatability in the thermosphere-ionosphere structure is consistent with that observed in multiyear aphelion temperature data of the Mars lower atmosphere. Coupled Mars general circulation model (MGCM) and Mars thermospheric general circulation model (MTGCM) codes are run for Mars aphelion conditions, yielding mean and longitude variable ionospheric peak heights that reasonably match RS observations. A tidal decomposition of MTGCM thermospheric densities shows that observed ionospheric wave number 3 features are linked to a non-migrating tidal mode with semidiurnal period (sigma = 2) and zonal wave number 1 (s = -1) characteristics. The height of this photochemically determined ionospheric peak should be monitored regularly.

  17. 7 CFR 61.30 - Examination of sampler.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Examination of sampler. 61.30 Section 61.30... Cottonseed Samplers § 61.30 Examination of sampler. Each applicant for a license as a sampler and each... examination or test to show his ability properly to perform the duties for which he is applying for a license...

  18. Remote Sampler Demonstration Isolok Configuration Test

    International Nuclear Information System (INIS)

    Kelly, Steve E.

    2016-01-01

    The accuracy and precision of a new Isolok sampler configuration was evaluated using a recirculation flow loop. The evaluation was performed using two slurry simulants of Hanford high-level tank waste. Through testing, the capability of the Isolok sampler was evaluated. Sample concentrations were compared to reference samples that were simultaneously collected by a two-stage Vezin sampler. The capability of the Isolok sampler to collect samples that accurately reflect the contents in the test loop improved – biases between the Isolok and Vezin samples were greatly reduce for fast settling particles.

  19. Remote Sampler Demonstration Isolok Configuration Test

    Energy Technology Data Exchange (ETDEWEB)

    Kelly, Steve E. [Washington River Protection Solutions, LLC, Richland, WA (United States)

    2016-06-08

    The accuracy and precision of a new Isolok sampler configuration was evaluated using a recirculation flow loop. The evaluation was performed using two slurry simulants of Hanford high-level tank waste. Through testing, the capability of the Isolok sampler was evaluated. Sample concentrations were compared to reference samples that were simultaneously collected by a two-stage Vezin sampler. The capability of the Isolok sampler to collect samples that accurately reflect the contents in the test loop improved – biases between the Isolok and Vezin samples were greatly reduce for fast settling particles.

  20. The MGS Avionics System Architecture: Exploring the Limits of Inheritance

    Science.gov (United States)

    Bunker, R.

    1994-01-01

    Mars Global Surveyor (MGS) avionics system architecture comprises much of the electronics on board the spacecraft: electrical power, attitude and articulation control, command and data handling, telecommunications, and flight software. Schedule and cost constraints dictated a mix of new and inherited designs, especially hardware upgrades based on findings of the Mars Observer failure review boards.

  1. Hayabusa2 Sampler: Collection of Asteroidal Surface Material

    Science.gov (United States)

    Sawada, Hirotaka; Okazaki, Ryuji; Tachibana, Shogo; Sakamoto, Kanako; Takano, Yoshinori; Okamoto, Chisato; Yano, Hajime; Miura, Yayoi; Abe, Masanao; Hasegawa, Sunao; Noguchi, Takaaki

    2017-07-01

    Japan Aerospace Exploration Agency (JAXA) launched the asteroid exploration probe "Hayabusa2" in December 3rd, 2014, following the 1st Hayabusa mission. With technological and scientific improvements from the Hayabusa probe, we plan to visit the C-type asteroid 162137 Ryugu (1999 JU3), and to sample surface materials of the C-type asteroid that is likely to be different from the S-type asteroid Itokawa and contain more pristine materials, including organic matter and/or hydrated minerals, than S-type asteroids. We developed the Hayabusa2 sampler to collect a minimum of 100 mg of surface samples including several mm-sized particles at three surface locations without any severe terrestrial contamination. The basic configuration of the sampler design is mainly as same as the 1st Hayabusa (Yano et al. in Science, 312(5778):1350-1353, 2006), with several minor but important modifications based on lessons learned from the Hayabusa to fulfill the scientific requirements and to raise the scientific value of the returned samples.

  2. Half-liter supernatant sampler system engineering work plan

    International Nuclear Information System (INIS)

    Ritter, G.A.

    1995-01-01

    The Tank Waste Remediation System (TWRS) pretreatment facility project W-236B, known as the Initial Pretreatment Module (IPM), requires samples of supernatants and sludges from 200 Area tank farms for planned hot testing work in support of IPM design. The IPM project has proposed the development of several new sampler systems. These systems include a 0.5-l supernatant sampler, 3-l and 25-l supernatant and sludge samplers, and a 4,000-l sampler system. The 0.5-l sampler will support IPM sampling needs in the 1 to 3 l range starting in late fiscal year 1995. This sampler is intended to be used in conjunction with the existing 100 ml bottle-on-a-string. The 3-l and 25-l systems will be based on the Savannah River Site's sampler system and will support IPM sampling needs in the 3 to 100 liter range. Most of the hot testing required for design of the IPM must be accomplished in the next 3 years. This work plan defines the tasks associated with the development of a 0.5-l sampler system. This system will be referred to as the Half-Liter Supernatant Sampler System (HLSSS). Specifically, this work plan will define the scope of work, identify organizational responsibilities, identify major technical requirements, describe configuration control and verification requirements, and provide estimated costs and schedule. The sampler system will be fully operational, including trained staff and operating procedures, upon completion of this task

  3. New Rhizon in situ sampler for pore water studies in aquatic sediments: For example nutrient input from submarine groundwater discharge in costal areas.

    OpenAIRE

    Seeberg-Elverfeldt, J.; Schlüter, Michael; Kölling, M.; Feseker, T.

    2005-01-01

    To investigate coastal biogeochemical cycles, especially at the sediment/water interface,improved sampling methods are necessary. For this purpose, we developed apore water in situ sampler with miniature sampling devices, so called Rhizons. Rhizonsoil moisture samplers have been used as sampling devices in unsaturated soilsfor the last ten years. In aquatic science they have been rarely used to extract porewater from sediments. This study presents a new developed Rhizon In Situ Sampler(RISS) ...

  4. Design of dry sand soil stratified sampler

    Science.gov (United States)

    Li, Erkang; Chen, Wei; Feng, Xiao; Liao, Hongbo; Liang, Xiaodong

    2018-04-01

    This paper presents a design of a stratified sampler for dry sand soil, which can be used for stratified sampling of loose sand under certain conditions. Our group designed the mechanical structure of a portable, single - person, dry sandy soil stratified sampler. We have set up a mathematical model for the sampler. It lays the foundation for further development of design research.

  5. Environmental monitoring of tritium in air with passive diffusion samplers

    International Nuclear Information System (INIS)

    Wood, M.J.; Workman, W.J.G.

    1992-01-01

    This paper reports on a field trail in which outdoor air was sampled with an active reference sampler and several passive HTO-in-air samplers simultaneously carried out at Chalk River Laboratories. Both passive and active samplers were changed on an approximately monthly schedule from 1990 September 2 to 1991 April 18. Average temperatures for the sampling intervals ranged from -8.06 degrees C to +15.5 degrees C and HTO-in-air concentrations measured by the active sampler were typically 10 Bq/m 3 . A total of 1290 passive HTO-in-air sampler measurements were made during the seven sampling intervals. The passive samplers used for the field trial were prepared with either tritium-free water or a solution of 50% tritium-free water and 50% ethylene glycol. As expected, the samplers prepared with the water-glycol solution performed more consistently than the samplers prepared with water only. Good agreement between passive and active sampler measurements was observed throughout the field trial

  6. Passive samplers and community science in regional air quality measurement, education and communication.

    Science.gov (United States)

    DeForest Hauser, Cindy; Buckley, Alexandra; Porter, Juliana

    2015-08-01

    Charlotte, in Mecklenburg County, North Carolina, was ranked in the top ten cities with the worst air quality for ozone in the United States by the American Lung Association from 2009 to 2011. Nearby counties that may experience similar air quality do not have state or county monitors. This study utilized NOx and ozone Ogawa passive samplers and community scientists to monitor air quality in five counties surrounding Charlotte and increase public engagement in air quality issues. Community scientists deployed samplers weekly at a residential site within each county. Samples were analyzed using spectrophotometry and ion chromatography. Elevated NOx concentrations were observed in four of the five counties relative to those with existing monitors. Ozone concentrations showed little county to county variation, except Iredell and Cabarrus which had higher concentrations than Rowan. Community involvement in this work led to an increase in local dissemination of the results, thus increasing air quality awareness. Copyright © 2014 Elsevier Ltd. All rights reserved.

  7. Performance improvements on passive activated charcoal 222Rn samplers

    International Nuclear Information System (INIS)

    Wei Suxia

    1996-01-01

    Improvements have been made on passive activated charcoal 222 Rn samplers with sintered metal filters. Based on the samplers of good adaptability to temperature and humidity developed before, better charcoal was selected to further improve their performance in radon absorption ability and moisture-resistance. And charcoal quantity in samplers was strictly controlled. The integration time constant of the improved samplers was about 4.3 days. As the sampler was combined with gamma spectrometer to measure radon concentration, the calibration factor was 0.518 min -1 ·Bq -1 ·m 3 for samplers of 7 days exposure time, and the minimum detectable concentration 0.28 Bq·m -3 if counting time for both background and sample is 1000 minutes. The improved samplers are suited to accurately determine the indoor and outdoor average radon concentration under conditions of great variation in temperature and humidity

  8. A passive sampler for atmospheric ozone

    International Nuclear Information System (INIS)

    Grosjean, D.; Hisham, M.W.M.

    1992-01-01

    A simple, cost-effective passive sampler has been developed for the determination of atmospheric ozone. This passive sampler is based on a colorant which fades upon reaction with ozone, whose concentration can be determined by reflectance measurement of the color change. Direct, on-site measurements are possible, and no chemical analyses are needed. Sampler design and validation studies have been carried out and included quantitative determination of color change vs exposure time (1-8 days), color change vs. ozone concentration (30-350 ppb), and response to changes in sampler configuration that modify the passive sampling rate. With indigo carmine as the colorant, the detection limits are 30 ppb. day and 120 ppb. day using a plastic grid and Teflon filter, respectively, as diffusion barriers. Interferences from nitrogen dioxide, formaldehyde and peroxyacetyl nitrate are 15, 4 and 16%, respectively, thus resulting in a negligible bias when measuring ozone in ambient air

  9. Characterization of the GENT PM10 sampler. Appendix 18

    International Nuclear Information System (INIS)

    Hopke, Philip K.; Xie Ying; Raunemaa, Taisto; Biegalski, Steven; Landsberger, Sheldon

    1995-01-01

    An integral part of the Co-ordinated Research Programme: Applied Research on Air Pollution using Nuclear-Related Analytical Techniques is the PM 10 sampler that was designed by Dr. W. Maenhaut of the University of Gent. Each participant was provided with such a sampler so that comparable samples will be obtained by each of the participating groups. Thus, in order to understand the characteristics of this sampler, we have undertaken several characterization studies in which we have examine the aerodynamic collection characteristics of the impactor inlet and the reproducibility of the sample mass collection. The sampler does provide a collection efficiency that follows the guidelines for a PM 10 sampler. Comparing one of the original samplers built at the University of Gent with a unit built from the same plans at Clarkson University showed good reproducibility in mass collection. (author)

  10. Statistical analysis of the DWPF prototypic sampler

    International Nuclear Information System (INIS)

    Postles, R.L.; Reeve, C.P.; Jenkins, W.J.; Bickford, D.F.

    1991-01-01

    The DWPF process will be controlled using assay measurements on samples of feed slurry. These slurries are radioactive, and thus will be sampled remotely. A Hydraguard trademark pump-driven sampler system will be used as the remote sampling device. A prototype Hydraguard trademark sampler has been studied in a full-scale mock-up of a DWPF process vessel. Two issues were of dominant interest: (1) what accuracy and precision can be provided by such a pump-driven sampler in the face of the slurry rheology; and, if the Hydraguard trademark sample accurately represents the slurry in its local area, (2) is the slurry homogeneous enough throughout for it to represent the entire vessel? To determine Hydraguard trademark Accuracy, a Grab Sampler of simpler mechanism was used as reference. This (Low) Grab Sampler was located as near to the intake port of the Hydraguard trademark as could be arranged. To determine Homogeneity, a second (High) Grab Sampler was located above the first. The data necessary to these determinations comes from the measurement system, so its important variables also affect the results. Thus, the design of the test involved not just Sampling variables, but also some of the Measurement variables as well. However, the main concern was the Sampler and not the Measurement System, so the test design included only such measurement variables as could not be circumvented (Vials, Dissolution Method, and Aliquoting). The test was executed by, or under the direct oversight of, expert technologists. It thus did not explore the many important particulars of ''routine'' plant operations (such as Remote Sample Preparation or Laboratory Shift Operation)

  11. Siting Samplers to Minimize Expected Time to Detection

    Energy Technology Data Exchange (ETDEWEB)

    Walter, Travis; Lorenzetti, David M.; Sohn, Michael D.

    2012-05-02

    We present a probabilistic approach to designing an indoor sampler network for detecting an accidental or intentional chemical or biological release, and demonstrate it for a real building. In an earlier paper, Sohn and Lorenzetti(1) developed a proof of concept algorithm that assumed samplers could return measurements only slowly (on the order of hours). This led to optimal detect to treat architectures, which maximize the probability of detecting a release. This paper develops a more general approach, and applies it to samplers that can return measurements relatively quickly (in minutes). This leads to optimal detect to warn architectures, which minimize the expected time to detection. Using a model of a real, large, commercial building, we demonstrate the approach by optimizing networks against uncertain release locations, source terms, and sampler characteristics. Finally, we speculate on rules of thumb for general sampler placement.

  12. Functional design criteria for the retained gas sampler system

    International Nuclear Information System (INIS)

    Wootan, D.W.

    1995-01-01

    A Retained Gas Sampler System (RGSS) is being developed to capture and analyze waste samples from Hanford Flammable Gas Watch List Tanks to determine both the quantity and composition of gases retained in the waste. The RGSS consists of three main components: the Sampler, Extractor, and Extruder. This report describes the functional criteria for the design of the RGSS components. The RGSS Sampler is based on the WHC Universal Sampler design with modifications to eliminate gas leakage. The primary function of the Sampler is to capture a representative waste sample from a tank and transport the sample with minimal loss of gas content from the tank to the laboratory. The function of the Extruder is to transfer the waste sample from the Sampler to the Extractor. The function of the Extractor is to separate the gases from the liquids and solids, measure the relative volume of gas to determine the void fraction, and remove and analyze the gas constituents

  13. A radon progeny sampler for the determination of effective dose

    Energy Technology Data Exchange (ETDEWEB)

    Solomon, S.B. [Australian Radiation Laboratory, Victoria (Australia)

    1997-12-01

    The design and simulated performance is described of a two-stage sampler (HE-Sampler) for {sup 222}Rn progeny. This HE-Sampler has a collection efficiency optimised to match the particle size dependency of the radon progeny dose conversion factor (DCF), derived from the latest Respiratory Tract Model of the International Commission on Radiological Protection, as implemented in the computer code RADEP. The He-Sampler comprises a wire screen pre-separator, matched to the nasal deposition, and a wire screen collector, matched to the respiratory tract collection. This HE-Sampler allows for the estimation of the radiation dose from the inhalation of {sup 222}Rn progeny, derived from two concurrent alpha particle activity measurements, one on the HE-Sampler screen collector and one on a reference filter sample. As a first approximation, the DCF is proportional to the collected fraction. The HE-Sampler response was simulated for a range of radon progeny size distributions to determine the error in the estimated DCF values. The simulation results show that the HE-Sampler is relatively insensitive to variations in sampling rate and in the screen parameters, particularly for environmental exposure. (Author).

  14. Particle capturing performance of South African non corrosive samplers

    CSIR Research Space (South Africa)

    Pretorius, C

    2010-05-01

    Full Text Available eq ue nc y D50 D90 © CSIR 2007 www.csir.co.za Particle size distribution of sampled filters taken in three platinum mines PSA results according to mine 0 2 4 6 8 10 12 14 16 X-Samplers Y-Samplers X-Samplers Y...

  15. Passive sampler for dissolved organic matter in freshwater environments.

    Science.gov (United States)

    Lam, Buuan; Simpson, André J

    2006-12-15

    A passive sampler for the isolation of dissolved organic matter (DOM) from freshwater environments is described. The sampler consists of a molecular weight selective membrane (1000 kDa) and an anion exchange resin (diethylaminoethylcellulose (DEAE-cellulose)). NMR indicates the samplers isolate DOM that is nearly indistinguishable from that isolated using the batch DEAE-cellulose procedure. In a comparative study DOM isolated from Lake Ontario cost approximately 0.30 dollars/mg to isolate using the passive samplers while DOM isolated using the traditional batch procedure cost approximately 8-10 dollars/mg. The samplers have been shown to be effective in a range of freshwater environments including a large inland lake (Lake Ontario), fast flowing tributary, and wetland. Large amounts (gram quantities of DOM) can be easily isolated by increasing the size or number of samplers deployed. Samplers are easy to construct, negate the need for pressure filtering, and also permit a range of temporal and spatial experiments that would be very difficult or impossible to perform using conventional approaches. For example, DOM can be monitored on a regular basis at numerous different locations, or samplers could be set at different depths in large lakes. Furthermore, they could potentially be deployed into hard to reach environments such as wells, groundwater aquifers, etc., and as they are easy to use, they can be mailed to colleagues or included with expeditions going to difficult to reach places such as the Arctic and Antarctic.

  16. Particle-capturing performance of South African non-corrosive samplers

    CSIR Research Space (South Africa)

    Pretorius, CJ

    2011-10-01

    Full Text Available analysis (PSA) could be carried out. The duration of the sampling was established at ? 30 seconds, so the mass of dust collected per sample ranged from 1 to 2 mg. The flow rates for each sampler were specified by the suppliers. For the X... chain to eliminate pulsation in the air flow. The pressure loss due to air flow resistance was measured with a digital micro manometer for each sampler with 2.2 L/min passing through the sampler (2.5 L/min for the aluminium samplers). PSA...

  17. Rocksalt MgS solar blind ultra-violet detectors

    Directory of Open Access Journals (Sweden)

    Ying-Hoi Lai

    2012-03-01

    Full Text Available Studies using in-situ Auger electron spectroscopy and reflection high energy electron diffraction, and ex-situ high resolution X-ray diffraction and electron backscatter diffraction reveal that a MgS thin film grown directly on a GaAs (100 substrate by molecular beam epitaxy adopts its most stable phase, the rocksalt structure, with a lattice constant of 5.20 Å. A Au/MgS/n+-GaAs (100 Schottky-barrier photodiode was fabricated and its room temperature photoresponse was measured to have a sharp fall-off edge at 235 nm with rejection of more than three orders at 400 nm and higher than five orders at 500 nm, promising for various solar-blind UV detection applications.

  18. Environmental HTO/HT sampler development

    International Nuclear Information System (INIS)

    Workman, W.J.G.; Brown, R.M.; Wood, M.J.

    1992-12-01

    Tests of retention by several drying agents of HTO from an air stream containing HT have been performed. Two batches of Molecular Sieve (MS) 4A retained up to 1.3% of HT passed through them in contrast to material tested in 1986, when retention was -4 . Retention of 10 -5 to 10 -6 was observed for DRIERITE (anhydrous calcium sulphate) and Silica Gel. DRIERITE is preferred over Silica Gel as a desiccant in an air sampler for environmental HTO/HT, because it is much easier to decontaminate for reuse. An improved air sampler has been designed, 2 units constructed and components procured for 3 more. The air sampler may be line or battery operated, accommodates up to four 120 g drier or oxidizer traps, and will pump up to 4 L/min for up to 24 hours on battery power. It is build into a rugged aluminum case and weighs approximately 11 kg overall, facilitating deployment in the field

  19. Environmental HTO/HT sampler development

    International Nuclear Information System (INIS)

    Workman, W.J.G.; Brown, R.M.; Wood, M.J.

    1994-01-01

    Tests of retention by several drying agents of HTO from an air stream containing HT have been performed. Two batches of Molecular Sieve (MS) 4A retained up to 1.3% of HT passed through them, in contrast to material tested in 1986, when retention was -4 . Retention of 10 -5 to 10 -6 was observed for DRIERITE (anhydrous calcium sulphate) and Silica Gel. DRIERITE is preferred over Silica Gel as a desiccant in an air sampler for environmental HTO/HT, because it is much easier to decontaminate for reuse. An improved air sampler has been designed, 2 units constructed and components procured for 3 more. The air sampler may be line or battery operated, accommodates up to four 120 g drier or oxidizer traps, and will pump up to 4 L/min for up to 24 hours on battery power. It is built into a rugged aluminum case and weighs approximately 11 kg overall, facilitating deployment in the field. (author). 5 refs., 2 tabs., 4 figs

  20. Comparison of the sampling rates and partitioning behaviour of polar and non-polar contaminants in the polar organic chemical integrative sampler and a monophasic mixed polymer sampler for application as an equilibrium passive sampler.

    Science.gov (United States)

    Jeong, Yoonah; Schäffer, Andreas; Smith, Kilian

    2018-06-15

    In this work, Oasis HLB® beads were embedded in a silicone matrix to make a single phase passive sampler with a higher affinity for polar and ionisable compounds than silicone alone. The applicability of this mixed polymer sampler (MPS) was investigated for 34 aquatic contaminants (log K OW -0.03 to 6.26) in batch experiments. The influence of flow was investigated by comparing uptake under static and stirred conditions. The sampler characteristics of the MPS was assessed in terms of sampling rates (R S ) and sampler-water partition coefficients (K SW ), and these were compared to those of the polar organic chemical integrative sampler (POCIS) as a reference kinetic passive sampler. The MPS was characterized as an equilibrium sampler for both polar and non-polar compounds, with faster uptake rates and a shorter time to reach equilibrium than the POCIS. Water flow rate impacted sampling rates by up to a factor of 12 when comparing static and stirred conditions. In addition, the relative accumulation of compounds in the polyethersulfone (PES) membranes versus the inner Oasis HLB sorbent was compared for the POCIS, and ranged from <1% to 83% depending on the analyte properties. This is indicative of a potentially significant lag-phase for less polar compounds within POCIS. The findings of this study can be used to quantitatively describe the partitioning and kinetic behaviour of MPS and POCIS for a range of aquatic organic contaminants for application in field sampling. Copyright © 2018 Elsevier B.V. All rights reserved.

  1. Seasonal and Static Gravity Field of Mars from MGS, Mars Odyssey and MRO Radio Science

    Science.gov (United States)

    Genova, Antonio; Goossens, Sander; Lemoine, Frank G.; Mazarico, Erwan; Neumann, Gregory A.; Smith, David E.; Zuber, Maria T.

    2016-01-01

    We present a spherical harmonic solution of the static gravity field of Mars to degree and order 120, GMM-3, that has been calculated using the Deep Space Network tracking data of the NASA Mars missions, Mars Global Surveyor (MGS), Mars Odyssey (ODY), and the Mars Reconnaissance Orbiter (MRO). We have also jointly determined spherical harmonic solutions for the static and time-variable gravity field of Mars, and the Mars k 2 Love numbers, exclusive of the gravity contribution of the atmosphere. Consequently, the retrieved time-varying gravity coefficients and the Love number k 2 solely yield seasonal variations in the mass of the polar caps and the solid tides of Mars, respectively. We obtain a Mars Love number k 2 of 0.1697 +/-0.0027 (3- sigma). The inclusion of MRO tracking data results in improved seasonal gravity field coefficients C 30 and, for the first time, C 50 . Refinements of the atmospheric model in our orbit determination program have allowed us to monitor the odd zonal harmonic C 30 for approx.1.5 solar cycles (16 years). This gravity model shows improved correlations with MOLA topography up to 15% larger at higher harmonics ( l = 60–80) than previous solutions.

  2. A Passive Diffusion Sampler for HT- and HTO-in-Air

    International Nuclear Information System (INIS)

    Surette, R.A.; Nunes, J.C.

    2005-01-01

    Fusion research and tritium removal facilities potentially handle large inventories of tritium gas (HT). If any HT is released into the workplace, a fraction may be converted to tritiated water vapour (HTO). A convenient method to determine the activity concentration of each species is necessary to assess the potential hazard since the radiological hazard of HTO is more than 10 4 that due to HT. Passive samplers for measuring tritiated water vapour (HTO) have been shown to be suitable for use indoors and outdoors. These simple samplers consist of a standard 20-mL liquid scintillation vial with a diffusion orifice that determines the sampling rate.The total tritium samplers described herein are passive or diffusion samplers that contain a small amount of AECL-proprietary wet-proofed catalyst fixed to the underside of the sampling heads to allow conversion of the HT to HTO that is subsequently collected in the sink, (HTO), in the bottom of the sampler. After an appropriate sampling time, liquid scintillation cocktail is added to the vial and the activity collected determined by liquid scintillation analysis. When used in conjunction with the conventional HTO passive sampler the difference between the total and HTO samplers can be used to determine the HT fraction ((HT+HTO) - HTO HT). The sampling rates for the modified diffusion sampler were measured to be 4.6 and 8.1 L/d for HTO and HT, respectively. For a fifteen-minute sampling period, passive samplers can be used to measure tritium activity concentrations from 37 kBq/m 3 to 115 MBq/m 3

  3. Sampler collection gadget for epilithic diatoms.

    Science.gov (United States)

    Salomoni, S E; Torgan, L C; Rocha, O

    2007-11-01

    This work present a new gadget for sampling epilithic diatoms from both lentic and lotic enviroments. The sampler consists of a polystyrene cylinder, left to float on the surface of the water, to which stone substrates are attached. This epilithic diatom sampler (EDS) can be used to detect spatial and temporal richness and density variation in the study of the diatom community, as well as in water quality monitoring.

  4. 50 CFR 697.12 - At-sea sea sampler/observer coverage.

    Science.gov (United States)

    2010-10-01

    ... sampler/observer access to and use of the vessel's communications equipment and personnel upon request for...) Allow the sea sampler/observer to inspect and copy the vessel's log, communications log, and records... must: (1) Notify the sea sampler/observer of any sea turtles, marine mammals, or other specimens taken...

  5. Automated particulate sampler field test model operations guide

    Energy Technology Data Exchange (ETDEWEB)

    Bowyer, S.M.; Miley, H.S.

    1996-10-01

    The Automated Particulate Sampler Field Test Model Operations Guide is a collection of documents which provides a complete picture of the Automated Particulate Sampler (APS) and the Field Test in which it was evaluated. The Pacific Northwest National Laboratory (PNNL) Automated Particulate Sampler was developed for the purpose of radionuclide particulate monitoring for use under the Comprehensive Test Ban Treaty (CTBT). Its design was directed by anticipated requirements of small size, low power consumption, low noise level, fully automatic operation, and most predominantly the sensitivity requirements of the Conference on Disarmament Working Paper 224 (CDWP224). This guide is intended to serve as both a reference document for the APS and to provide detailed instructions on how to operate the sampler. This document provides a complete description of the APS Field Test Model and all the activity related to its evaluation and progression.

  6. Sampler collection gadget for epilithic diatoms

    Directory of Open Access Journals (Sweden)

    SE. Salomoni

    Full Text Available This work present a new gadget for sampling epilithic diatoms from both lentic and lotic enviroments. The sampler consists of a polystyrene cylinder, left to float on the surface of the water, to which stone substrates are attached. This epilithic diatom sampler (EDS can be used to detect spatial and temporal richness and density variation in the study of the diatom community, as well as in water quality monitoring.

  7. Coalescent genealogy samplers: windows into population history.

    Science.gov (United States)

    Kuhner, Mary K

    2009-02-01

    Coalescent genealogy samplers attempt to estimate past qualities of a population, such as its size, growth rate, patterns of gene flow or time of divergence from another population, based on samples of molecular data. Genealogy samplers are increasingly popular because of their potential to disentangle complex population histories. In the last decade they have been widely applied to systems ranging from humans to viruses. Findings include detection of unexpected reproductive inequality in fish, new estimates of historical whale abundance, exoneration of humans for the prehistoric decline of bison and inference of a selective sweep on the human Y chromosome. This review summarizes available genealogy-sampler software, including data requirements and limitations on the use of each program.

  8. Enhanced surface sampler and process for collection and release of analytes

    Energy Technology Data Exchange (ETDEWEB)

    Addleman, Raymond S; Atkinson, David A; Bays, John T; Chouyyok, Wilaiwan; Cinson, Anthony D; Ewing, Robert G; Gerasimenko, Aleksandr A

    2015-02-03

    An enhanced swipe sampler and method of making are described. The swipe sampler is made of a fabric containing selected glass, metal oxide, and/or oxide-coated glass or metal fibers. Fibers are modified with silane ligands that are directly attached to the surface of the fibers to functionalize the sampling surface of the fabric. The swipe sampler collects various target analytes including explosives and other threat agents on the surface of the sampler.

  9. Quantum Gibbs Samplers: The Commuting Case

    Science.gov (United States)

    Kastoryano, Michael J.; Brandão, Fernando G. S. L.

    2016-06-01

    We analyze the problem of preparing quantum Gibbs states of lattice spin Hamiltonians with local and commuting terms on a quantum computer and in nature. Our central result is an equivalence between the behavior of correlations in the Gibbs state and the mixing time of the semigroup which drives the system to thermal equilibrium (the Gibbs sampler). We introduce a framework for analyzing the correlation and mixing properties of quantum Gibbs states and quantum Gibbs samplers, which is rooted in the theory of non-commutative {mathbb{L}_p} spaces. We consider two distinct classes of Gibbs samplers, one of them being the well-studied Davies generator modelling the dynamics of a system due to weak-coupling with a large Markovian environment. We show that their spectral gap is independent of system size if, and only if, a certain strong form of clustering of correlations holds in the Gibbs state. Therefore every Gibbs state of a commuting Hamiltonian that satisfies clustering of correlations in this strong sense can be prepared efficiently on a quantum computer. As concrete applications of our formalism, we show that for every one-dimensional lattice system, or for systems in lattices of any dimension at temperatures above a certain threshold, the Gibbs samplers of commuting Hamiltonians are always gapped, giving an efficient way of preparing the associated Gibbs states on a quantum computer.

  10. Assessment the impact of samplers change on the uncertainty related to geothermalwater sampling

    Science.gov (United States)

    Wątor, Katarzyna; Mika, Anna; Sekuła, Klaudia; Kmiecik, Ewa

    2018-02-01

    The aim of this study is to assess the impact of samplers change on the uncertainty associated with the process of the geothermal water sampling. The study was carried out on geothermal water exploited in Podhale region, southern Poland (Małopolska province). To estimate the uncertainty associated with sampling the results of determinations of metasilicic acid (H2SiO3) in normal and duplicate samples collected in two series were used (in each series the samples were collected by qualified sampler). Chemical analyses were performed using ICP-OES method in the certified Hydrogeochemical Laboratory of the Hydrogeology and Engineering Geology Department at the AGH University of Science and Technology in Krakow (Certificate of Polish Centre for Accreditation No. AB 1050). To evaluate the uncertainty arising from sampling the empirical approach was implemented, based on double analysis of normal and duplicate samples taken from the same well in the series of testing. The analyses of the results were done using ROBAN software based on technique of robust statistics analysis of variance (rANOVA). Conducted research proved that in the case of qualified and experienced samplers uncertainty connected with the sampling can be reduced what results in small measurement uncertainty.

  11. The influence of geometry and draught shields on the performance of passive samplers.

    Science.gov (United States)

    Hofschreuder, P; van der Meulen, W; Heeres, P; Slanina, S

    1999-04-01

    Passive samplers provide an excellent opportunity to perform indicative measurements or establish a dense network of measuring sites. A drawback compared with conventional active measuring methods is the larger spread of results. This variation can, to a large extent, be attributed to the influence of temperature, sampler geometry and wind on sampling results. A proper design of sampler geometry and optimum choice of draught shield can reduce the influence of wind velocity on a badge type sampler to less than 10%. Wire mesh screens prove to be inadequate in damping turbulence. Filters give good results. Attention should be paid to the size and isolation value of the walls of the sampler to prevent thermal updrafts occurring within the sampler. Tube type samplers are less influenced by wind, provided that turbulence is prevented from influencing diffusion within the sampler.

  12. Task plan for test of PRBT prototypic liquid sampler

    International Nuclear Information System (INIS)

    Jenkins, W.J.

    1992-01-01

    The primary objective of this task is to determine just how representative Precipitate Reactor Bottom Tank (PRBT) samples taken from the Hydragard trademark prototypic liquid sampler are of the in-tank contents and also to determine the homogeneity of the in-tank contents. This shall be accomplished by a statistical design study sampling plan for paired contrasts of the analysis results of samples taken from: (1) the Hydragard trademark prototypic liquid sampler paired with the more fundamental grab sampler at the lower elevation for the Hydragard trademark prototypic liquid sampler accuracy and (2) the grab sampler at the lower elevation paired with the grab sampler at the upper elevation for the in-tank homogeneity. These measurements are paired together to sharpen the contrast so that, as nearly as possible, only the conditions of the effect under study will differ between the two. This ''split-plot'' arrangement provides increased precision for the contrast under study by canceling out common extraneous effects, thereby enabling the detection of smaller effects. The secondary objective of the task is to determine the level of influence of the major contributors to the overall uncertainty in the sample preparation and measurement process. These major steps include: preparation method (H 2 SO 4 -HF Titanium dissolution); aliquoting and dilution within a dissolution; measurement and long-term behavior of the ICP and AA instruments, as monitored by the measurement of standards and blanks embedded within each block of samples for the measurement sequence. This sampling task, therefore, is mostly devoted to determining the sampler characteristics and is not intended to provide a comprehensive estimate of the overall uncertainty affecting DWPF sample analysis in routine operation

  13. A mini-sampler for welding aerosol mounted in close vicinity of the mouth/nose

    International Nuclear Information System (INIS)

    Liden, Goeran; Surakka, Jouni

    2009-01-01

    A small personal aerosol mini-sampler to be used inside modern welding visors has been developed. The main object of the mini-sampler has been to sample manganese. The sampler is based on commercially available 13 mm filter holders but modified to incorporate an inlet nozzle made of aluminium. The nominal flow rate of the mini-sampler is 0,75 l/min. The sampler is to be worn mounted on a headset, modified from professional microphone headsets. The headset mounting arrangement was accepted by the welders. The sampling bias of the mini sampler versus the IOM sampler depends on the coarseness of the sampled aerosol. At the lowest concentration ratio of the open-face 25 mm filter holder to the IOM sampler equal to 0,65, the bias of the mini sampler is approximately -26% versus the IOM. The RMS sampling bias of the mini sampler versus the IOM sampler for manganese is -4,6%. The inhalable fraction of welding aerosol mass consists only of 25-55% of welding fume. The rest of the mass is made up of spatter particles and grinding particles. For manganese generally more than 65% is found in the fume.

  14. Operability test report for 211BA flow proportional sampler

    International Nuclear Information System (INIS)

    Weissenfels, R.D.

    1995-01-01

    This operability report will verify that the 211-BA flow proportional sampler functions as intended by design. The sampler was installed by Project W-007H and is part of BAT/AKART for the BCE liquid effluent stream

  15. Optimal relaxed causal sampler using sampled-date system theory

    NARCIS (Netherlands)

    Shekhawat, Hanumant; Meinsma, Gjerrit

    This paper studies the design of an optimal relaxed causal sampler using sampled data system theory. A lifted frequency domain approach is used to obtain the existence conditions and the optimal sampler. A state space formulation of the results is also provided. The resulting optimal relaxed causal

  16. Observation of 45 GHz current waveforms using HTS sampler

    International Nuclear Information System (INIS)

    Maruyama, M.; Suzuki, H.; Hato, T.; Wakana, H.; Nakayama, K.; Ishimaru, Y.; Horibe, O.; Adachi, S.; Kamitani, A.; Suzuki, K.; Oshikubo, Y.; Tarutani, Y.; Tanabe, K.

    2005-01-01

    We succeeded in observing high-frequency current waveforms up to 45 GHz using a high-temperature superconducting (HTS) sampler. In this experiment, we used a sampler circuit with a superconducting pickup coil, which magnetically detects current signals flowing through a micro-strip line on a printed board placed outside the cryochamber. This type of measurement enables non-contact current-waveform observation that seems useful for analyses of EMI, defects in LSI, etc. Computer simulation reveals that one of our latest versions of HTS sampler circuits having Josephson transmission lines with optimized biases as buffers has a potential of sampling high-frequency signals with a bandwidth above 100 GHz. To realize the circuit parameters required in the simulations, we developed an HTS circuit fabrication process employing a lower ground plane structure with SrSnO 3 insulating layers. We consider that improvement of the circuit fabrication process and optimization of the pickup coil lead to much higher signal frequency observable by the sampler

  17. Operability test procedure for 211BA flow proportional sampler

    International Nuclear Information System (INIS)

    Weissenfels, R.D.

    1994-01-01

    The purpose of this operability test procedure (OTP) is to verify the 211-BA flow proportional sampler system and components function correctly as intended by design. System test will include the sampling system, all associated instrumentation, and Facility Process Monitor and Control System (FPMCS). The combined chemical sewer stream from B Plant flows through sump 211BA-SMP-01 located in 211-BA and is continuously monitored for gamma and beta radiation and pH. 211-BA has been upgraded to include a flow proportional sampler. A specified sample volume will be withdrawn at programmed intervals from the 211BA sump and deposited in a 19 liter plastic carboy. The sampler will be programmed per the vendor installation and operations manual by B Plant instrument maintenance personnel. Samples will be taken during five consecutive sample cycles with the sample volumes and sample frequencies recorded for comparison purposes. Additional tests related to the sampler include the alarm circuitry for loss of power and failure to obtain sample

  18. Evaluation of IOM personal sampler at different flow rates.

    Science.gov (United States)

    Zhou, Yue; Cheng, Yung-Sung

    2010-02-01

    The Institute of Occupational Medicine (IOM) personal sampler is usually operated at a flow rate of 2.0 L/min, the rate at which it was designed and calibrated, for sampling the inhalable mass fraction of airborne particles in occupational environments. In an environment of low aerosol concentrations only small amounts of material are collected, and that may not be sufficient for analysis. Recently, a new sampling pump with a flow rate up to 15 L/min became available for personal samplers, with the potential of operating at higher flow rates. The flow rate of a Leland Legacy sampling pump, which operates at high flow rates, was evaluated and calibrated, and its maximum flow was found to be 10.6 L/min. IOM samplers were placed on a mannequin, and sampling was conducted in a large aerosol wind tunnel at wind speeds of 0.56 and 2.22 m/s. Monodisperse aerosols of oleic acid tagged with sodium fluorescein in the size range of 2 to 100 microm were used in the test. The IOM samplers were operated at flow rates of 2.0 and 10.6 L/min. Results showed that the IOM samplers mounted in the front of the mannequin had a higher sampling efficiency than those mounted at the side and back, regardless of the wind speed and flow rate. For the wind speed of 0.56 m/s, the direction-averaged (the average value of all orientations facing the wind direction) sampling efficiency of the samplers operated at 2.0 L/min was slightly higher than that of 10.6 L/min. For the wind speed of 2.22 m/s, the sampling efficiencies at both flow rates were similar for particles < 60 microm. The results also show that the IOM's sampling efficiency at these two different flow rates follows the inhalable mass curve for particles in the size range of 2 to 20 microm. The test results indicate that the IOM sampler can be used at higher flow rates.

  19. Radial diffusive sampler for the determination of 8-h ambient ozone concentrations

    International Nuclear Information System (INIS)

    Plaisance, H.; Gerboles, M.; Piechocki, A.; Detimmerman, F.; Saeger, E. de

    2007-01-01

    The 8-h ozone radial diffusive sampler was evaluated according to the CEN protocol for the validation of diffusive samplers. All the parameters regarding the sampler characteristics were found to be consistent with the requirements of this protocol apart from the blank value, which must be evaluated and subtracted at each sampling. The nominal uptake rate was determined in laboratory conditions. However, the uptake rate depends on the mass uptake, temperature, humidity and on the combination of temperature and humidity. Based on laboratory experiments, an empirical model has been established which improved the agreement between the radial sampler and the reference method. This improvement was observed under several different meteorological and emission conditions of sampling. By using the model equation of uptake rate, the data quality objective of 30% for the expanded uncertainty included in the O 3 European Directive, is easily attained. Therefore, the sampler represents an appropriate indicative method. - A passive sampler has been fully validated for monitoring 8-h ozone concentrations in ambient air

  20. Evaluation of air samplers and filter materials for collection and recovery of airborne norovirus.

    Science.gov (United States)

    Uhrbrand, K; Koponen, I K; Schultz, A C; Madsen, A M

    2018-04-01

    The aim of this study was to identify the most efficient sampling method for quantitative PCR-based detection of airborne human norovirus (NoV). A comparative experiment was conducted in an aerosol chamber using aerosolized murine norovirus (MNV) as a surrogate for NoV. Sampling was performed using a nylon (NY) filter in conjunction with four kinds of personal samplers: Gesamtstaubprobenahme sampler (GSP), Triplex-cyclone sampler (TC), 3-piece closed-faced Millipore cassette (3P) and a 2-stage NIOSH cyclone sampler (NIO). In addition, sampling was performed using the GSP sampler with four different filter types: NY, polycarbonate (PC), polytetrafluoroethylene (PTFE) and gelatine (GEL). The sampling efficiency of MNV was significantly influenced by both sampler and filter type. The GSP sampler was found to give significantly (P airborne NoV. The identification of a suitable NoV air sampler is an important step towards studying the association between exposure to airborne NoV and infection. © 2017 The Society for Applied Microbiology.

  1. Electronic and structural properties of MgS and CaS

    International Nuclear Information System (INIS)

    Madu, C.A.; Onwuagba, B.N.

    2005-12-01

    The electronic and structural properties of MgS and CaS rocksalt structure are studied with the first principle full Potential Linearized Augmented Plane Wave (FP-LAPW) method. The exchange-correlation potential was calculated within the Generalized Gradient Approximation (GGA) using the Perdew-Burke-Ernzerhof (PBE-GGA) scheme. The scalar relativistic approach was adopted for the valence states, whereas the core states are treated fully relativistically. Energy band structures, density of states and structural parameters of both compounds are presented and discussed in context with the available theoretical and experimental studies. Our results are good and show reasonable agreement with previous results even though sufficient experimental values are not available for more realistic comparison. (author)

  2. Evaluation of air samplers and filter materials for collection and recovery of airborne norovirus

    DEFF Research Database (Denmark)

    Uhrbrand, Katrine; Kalevi Koponen, Ismo; Schultz, Anna Charlotte

    2017-01-01

    V. Sampling was performed using a nylon (NY) filter in conjunction with four kinds of personal samplers; Gesamtstaubprobenahme sampler (GSP), Triplex-cyclone sampler (TC), 3-piece closed-faced Millipore cassette (3P) and a 2-stage NIOSH cyclone sampler (NIO). In addition, sampling was performed using the GSP...

  3. Comparison of PM collection efficiency of Gent and Airmatrics MiniVol portable air sampler

    International Nuclear Information System (INIS)

    Begum, Bilkis A.; Biswas, Swapan K.

    2005-01-01

    Gent PM sampler was developed as an integral part of several International Atomic Energy Agency sponsored coordinated research programmes (CRP) for collecting air particulate samples. On the other hand, the MiniVol Portable Air Sampler is a commercial ambient air sampler for particulate matter and non-reactive gases used by different agencies. Air quality management system requires comparable air quality data to be collected by different stake holders for assessment and regulatory purposes. In order to compare the characteristics of Gent sampler with the MiniVol Portable Air Sampler, the reproducibility of the sample mass collection efficiency were examined and the measured mass concentrations were compared. It was found that in case of PM 10 both samplers collect almost same fraction of PM 10 mass when the Gent sampler was operated at 16 litre per minute flow rate. But in case of fine fraction, Portable sampler collects 70% higher PM 2.5 mass concentration compared to the Gent PM 2.2 mass concentrations. This is because, the Gent sampler was typically operated at 16 to 17 lpm resulting in an estimated 50% cut point of 2.2 μm.(author)

  4. The OPEnSampler: A Low-Cost, Low-Weight, Customizable and Modular Open Source 24-Unit Automatic Water Sampler

    Science.gov (United States)

    Nelke, M.; Selker, J. S.; Udell, C.

    2017-12-01

    Reliable automatic water samplers allow repetitive sampling of various water sources over long periods of time without requiring a researcher on site, reducing human error as well as the monetary and time costs of traveling to the field, particularly when the scale of the sample period is hours or days. The high fixed cost of buying a commercial sampler with little customizability can be a barrier to research requiring repetitive samples, such as the analysis of septic water pre- and post-treatment. DIY automatic samplers proposed in the past sacrifice maximum volume, customizability, or scope of applications, among other features, in exchange for a lower net cost. The purpose of this project was to develop a low-cost, highly customizable, robust water sampler that is capable of sampling many sources of water for various analytes. A lightweight aluminum-extrusion frame was designed and assembled, chosen for its mounting system, strength, and low cost. Water is drawn from two peristaltic pumps through silicone tubing and directed into 24 foil-lined 250mL bags using solenoid valves. A programmable Arduino Uno microcontroller connected to a circuit board communicates with a battery operated real-time clock, initiating sampling stages. Period and volume settings are programmable in-field by the user via serial commands. The OPEnSampler is an open design, allowing the user to decide what components to use and the modular theme of the frame allows fast mounting of new manufactured or 3D printed components. The 24-bag system weighs less than 10kg and the material cost is under $450. Up to 6L of sample water can be drawn at a rate of 100mL/minute in either direction. Faster flowrates are achieved by using more powerful peristaltic pumps. Future design changes could allow a greater maximum volume by filling the unused space with more containers and adding GSM communications to send real time status information.

  5. Pesticide monitoring in surface water and groundwater using passive samplers

    Science.gov (United States)

    Kodes, V.; Grabic, R.

    2009-04-01

    Passive samplers as screening devices have been used within a czech national water quality monitoring network since 2002 (SPMD and DGT samplers for non polar substances and metals). The passive sampler monitoring of surface water was extended to polar substances, in 2005. Pesticide and pharmaceutical POCIS samplers have been exposed in surface water at 21 locations and analysed for polar pesticides, perfluorinated compounds, personal care products and pharmaceuticals. Pesticide POCIS samplers in groundwater were exposed at 5 locations and analysed for polar pesticides. The following active substances of plant protection products were analyzed in surface water and groundwater using LC/MS/MS: 2,4,5-T, 2,4-D, Acetochlor, Alachlor, Atrazine, Atrazine_desethyl, Azoxystrobin, Bentazone, Bromacil, Bromoxynil, Carbofuran, Clopyralid, Cyanazin, Desmetryn, Diazinon, Dicamba, Dichlobenil, Dichlorprop, Dimethoat, Diuron, Ethofumesate, Fenarimol, Fenhexamid, Fipronil, Fluazifop-p-butyl, Hexazinone, Chlorbromuron, Chlorotoluron, Imazethapyr, Isoproturon, Kresoxim-methyl, Linuron, MCPA, MCPP, Metalaxyl, Metamitron, Methabenzthiazuron, Methamidophos, Methidathion, Metobromuron, Metolachlor, Metoxuron, Metribuzin, Monolinuron, Nicosulfuron, Phorate, Phosalone, Phosphamidon, Prometryn, Propiconazole, Propyzamide, Pyridate, Rimsulfuron, Simazine, Tebuconazole, Terbuthylazine, Terbutryn, Thifensulfuron-methyl, Thiophanate-methyl and Tri-allate. The POCIS samplers performed very well being able to provide better picture than grab samples. The results show that polar pesticides and also perfluorinated compounds, personal care products and pharmaceuticals as well occur in hydrosphere of the Czech republic. Acknowledgment: Authors acknowledge the financial support of grant No. 2B06095 by the Ministry of Education, Youth and Sports.

  6. 30 CFR 74.5 - Tests of coal mine dust personal sampler units.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Tests of coal mine dust personal sampler units... Personal Sampler Unit § 74.5 Tests of coal mine dust personal sampler units. (a) The National Institute for... tests and evaluations to determine whether the pump unit of a CMDPSU that is submitted for approval...

  7. A programmable air sampler with adsorption tubes

    International Nuclear Information System (INIS)

    Riesing, J.; Roetzer, H.; Hick, H.

    1997-01-01

    The Air Sampler AS3 was utilized for the European Tracer Experiment (ETEX) to measure the concentrations of the perfluorocarbon tracers. At thirty-two sampling points these devices were placed to collect the tracer substances in adsorption tubes for subsequent laboratory analysis in the Environment Institute of the JRC Ispra. The Air Sampler is also suitable for monitoring the environment, particularly of industrial emitters or landfills, by sampling of volatile substances. The Air Sampler AS3 is a portable, user-friendly instrument due to light weight, ruggedness and reliable operation. It is capable of fully automatic sampling of air and gas with 24 adsorption tubes and program-controlled gas flow. Collection times can be programmed freely between 1 sec and 8 days and waiting times between 1 sec and 30 days. Programming is possible via keyboard, memory card or serial interface. A protocol of sampling control data is stored on a memory card giving documentation of sampling conditions. On the memory card there is space for the storage of 10 sampling programs and 10 sets of sampling control data. Before the start of ETEX the AS3 was used in a measurement campaign to measure the background concentrations of the perfluorocarbon tracers in Austria. In the provinces of Upper Austria and Salzburg the Air Sampler is used by the departments for environmental protection for the monitoring of BTX-concentrations in air. (author)

  8. Performance characteristics of a low-volume PM10 sampler

    Science.gov (United States)

    Four identical PM10 pre-separators, along with four identical low-volume (1m3 hr-1) total suspended particulate (TSP) samplers were tested side-by-side in a controlled laboratory particulate matter (PM) chamber. The four PM10 and four TSP samplers were also tested in an oil pipe-cleaning field to ev...

  9. The effects of ambient conditions on the passive dust sampler when used in coal mines

    Energy Technology Data Exchange (ETDEWEB)

    Hemingway, M.; Thorpe, A.

    1998-09-01

    A previous feasibility study of the Health and Safety Laboratory (HSL) electret-based passive dust sampler carried out during site sampling in coal mines showed that the measurements made with the passive sampler and those made with the MRE sampler correlated well in each of two mines, but the ratios of samples obtained with the passive sampler and the MRE sampler in the two mines were different. This means the passive sampler would need a separate calibration for each coal mine in which it was used. Laboratory tests and further underground trials were carried out to quantify the possible effects of temperature and humidity on ratios. The passive dust samplers used at Maltby Colliery in the UK were found to pass the acceptance criteria according to the CEN standard for the assessment of the performance of instruments for the measurement of airborne particles, provided that samplers exposed when coal was not being cut were not included in the analysis. Temperature and relative humidity slightly affected the behaviour of the passive sampler during laboratory trials and relative humidity was found to possibly affect the behaviour during field trials. Ventilation rates had no effect on the passive sampler behaviour but the orientation of the passive dust sampler with respect to air flow affected the behaviour during laboratory trials. Further work is needed to quantify effects. 7 refs., 14 figs., 3 tabs.

  10. The neighborhood MCMC sampler for learning Bayesian networks

    Science.gov (United States)

    Alyami, Salem A.; Azad, A. K. M.; Keith, Jonathan M.

    2016-07-01

    Getting stuck in local maxima is a problem that arises while learning Bayesian networks (BNs) structures. In this paper, we studied a recently proposed Markov chain Monte Carlo (MCMC) sampler, called the Neighbourhood sampler (NS), and examined how efficiently it can sample BNs when local maxima are present. We assume that a posterior distribution f(N,E|D) has been defined, where D represents data relevant to the inference, N and E are the sets of nodes and directed edges, respectively. We illustrate the new approach by sampling from such a distribution, and inferring BNs. The simulations conducted in this paper show that the new learning approach substantially avoids getting stuck in local modes of the distribution, and achieves a more rapid rate of convergence, compared to other common algorithms e.g. the MCMC Metropolis-Hastings sampler.

  11. COMPARISON OF THE PARTICLE SIZE DISTRIBUTION OF HEAVY-DUTY DIESEL EXHAUST USING A DILUTION TAIL-PIPE SAMPLER AND IN-PLUME SAMPLER DURING ON-ROAD OPERATION

    Science.gov (United States)

    The paper compares the particle size distribution of heavy-duty diesel exhaust using a dilution tail-pipe sampler and an in-plume sampler during on-road operation. EPA's On-road Diesel Emissions Characterization Facility, modified to incorporate particle measurement instrumentat...

  12. Field calibration of polyurethane foam (PUF) disk passive air samplers for PCBs and OC pesticides.

    Science.gov (United States)

    Chaemfa, Chakra; Barber, Jonathan L; Gocht, Tilman; Harner, Tom; Holoubek, Ivan; Klanova, Jana; Jones, Kevin C

    2008-12-01

    Different passive air sampler (PAS) strategies have been developed for sampling in remote areas and for cost-effective simultaneous spatial mapping of POPs (persistent organic pollutants) over differing geographical scales. The polyurethane foam (PUF) disk-based PAS is probably the most widely used. In a PUF-based PAS, the PUF disk is generally mounted inside two stainless steel bowls to buffer the air flow to the disk and to shield it from precipitation and light. The field study described in this manuscript was conducted to: compare performance of 3 different designs of sampler; to further calibrate the sampler against the conventional active sampler; to derive more information on field-based uptake rates and equilibrium times of the samplers. Samplers were also deployed at different locations across the field site, and at different heights up a meteorological tower, to investigate the possible influence of sampler location. Samplers deployed <5m above ground, and not directly sheltered from the wind gave similar uptake rates. Small differences in dimensions between the 3 designs of passive sampler chamber had no discernable effect on accumulation rates, allowing comparison with previously published data.

  13. Assembly, operation and disassembly manual for the Battelle Large Volume Water Sampler (BLVWS)

    International Nuclear Information System (INIS)

    Thomas, V.W.; Campbell, R.M.

    1984-12-01

    Assembly, operation and disassembly of the Battelle Large Volume Water Sampler (BLVWS) are described in detail. Step by step instructions of assembly, general operation and disassembly are provided to allow an operator completely unfamiliar with the sampler to successfully apply the BLVWS to his research sampling needs. The sampler permits concentration of both particulate and dissolved radionuclides from large volumes of ocean and fresh water. The water sample passes through a filtration section for particle removal then through sorption or ion exchange beds where species of interest are removed. The sampler components which contact the water being sampled are constructed of polyvinylchloride (PVC). The sampler has been successfully applied to many sampling needs over the past fifteen years. 9 references, 8 figures

  14. Summary report on the design of the retained gas sampler system (retained gas sampler, extruder and extractor)

    International Nuclear Information System (INIS)

    Wootan, D.W.; Bolden, R.C.; Bridges, A.E.; Cannon, N.S.; Chastain, S.A.; Hey, B.E.; Knight, R.C.; Linschooten, C.G.; Pitner, A.L.; Webb, B.J.

    1994-01-01

    This document summarizes work performs in Fiscal Year 1994 to develop the three main components of Retained Gas Sampler System (RGSS). These primary components are the Retained Gas Sampler (RGS), the Retained Gas Extruder (RGE), and the Retained Gas Extractor (RGEx). The RGS is based on the Westinghouse Hanford Company (WHC) Universal Sampler design, and includes modifications to reduce gas leakage. The primary data priorities for the RGSS are to measure the void fraction and the flammable gas concentration in the waste sample. Significant progress has been made in developing the RGSS. The RGSS is being developed by WHC to extract a representative waste sample from a Flammable Gas Watch List Tanks and to measure both the amount and composition of free and open-quotes boundclose quotes gases. Sudden releases of flammable gas mixtures are a safety concern for normal waste storage operations and eventual waste retrieval. Flow visualization testing was used to identify important fluid dynamic issues related to the sampling process. The primary data priorities for the RGSS are to measure the void fraction and the flammable gas concentration in the waste sample. The safety analysis for the RGSS is being performed by Los Alamos National Laboratory and is more than sixty percent (60%) complete

  15. AN AFFINE-INVARIANT SAMPLER FOR EXOPLANET FITTING AND DISCOVERY IN RADIAL VELOCITY DATA

    International Nuclear Information System (INIS)

    Hou Fengji; Hogg, David W.; Goodman, Jonathan; Weare, Jonathan; Schwab, Christian

    2012-01-01

    Markov chain Monte Carlo (MCMC) proves to be powerful for Bayesian inference and in particular for exoplanet radial velocity fitting because MCMC provides more statistical information and makes better use of data than common approaches like chi-square fitting. However, the nonlinear density functions encountered in these problems can make MCMC time-consuming. In this paper, we apply an ensemble sampler respecting affine invariance to orbital parameter extraction from radial velocity data. This new sampler has only one free parameter, and does not require much tuning for good performance, which is important for automatization. The autocorrelation time of this sampler is approximately the same for all parameters and far smaller than Metropolis-Hastings, which means it requires many fewer function calls to produce the same number of independent samples. The affine-invariant sampler speeds up MCMC by hundreds of times compared with Metropolis-Hastings in the same computing situation. This novel sampler would be ideal for projects involving large data sets such as statistical investigations of planet distribution. The biggest obstacle to ensemble samplers is the existence of multiple local optima; we present a clustering technique to deal with local optima by clustering based on the likelihood of the walkers in the ensemble. We demonstrate the effectiveness of the sampler on real radial velocity data.

  16. Differences in particle size distributions collected by two wood dust samplers: preliminary findings

    International Nuclear Information System (INIS)

    Campopiano, A.; Olori, A.; Basili, F.; Ramires, D.; Zakrzewska, A.M.

    2008-01-01

    The International Agency for Research on Cancer (IARC) classification of wood dust as carcinogenic to humans, and the threshold limit value (TLV) of 5 mg/m 3 weighted over an 8-hour work day as defined by Italian legislation, have raised the issue of dust risk assessments in all woodworking environments. The aim is to characterize the particle size distribution for wood particles collected by two samplers used for collecting the inhalable fraction: the IOM sampler (Institute of Occupational Medicine, Edinburgh, Scotland) and the conical sampler also known in Italy as conetto. These two sampling heads were chosen mainly because the Italian conical sampler, used in the past for total dust sampling, is the most widely used by the Italian Prevention Services and analysis laboratories in general, whereas the IOM sampler was specifically designed to collect the inhalable fraction of airborne particles. The devices were placed side by side within the worker's breathing zone. In addition, another IOM sampler not connected to the personal sampling pump was placed on the same worker, thus functioning as a passive sampler capable of collecting projectile particles normally produced during processing. A Scanning Electron Microscope (SEM) coupled with energy dispersive X-ray spectrometry (EDAX) was used to count the number of particles collected on the sampling filters. The size of each particle identified by the SEM was determined by measuring its mean diameter. The SEM analysis revealed that the average size of the largest particles collected by the conetto sampler did not exceed 150 μm, whereas the size of particles collected by the IOM sampler was up to 350 μm. Indeed, the analysis of the filters of the passive IOM samplers showed that particles with mean diameters larger than 100 μm were collected, although the calculated percentage was very low (on average, approximately 1%). This does not mean that their gravimetric contribution is negligible; indeed, the weight of

  17. Performance of prototype high-flow inhalable dust sampler in a livestock production facility.

    Science.gov (United States)

    Anthony, T Renée; Cai, Changjie; Mehaffy, John; Sleeth, Darrah; Volckens, John

    2017-05-01

    A high-flow inhalable sampler, designed for operational flow rates up to 10 L/min using computer simulations and examined in wind tunnel experiments, was evaluated in the field. This prototype sampler was deployed in collocation with an IOM (the benchmark standard sampler) in a swine farrowing building to examine the sampling performance for assessing concentrations of inhalable particulate mass and endotoxin. Paired samplers were deployed for 24 hr on 19 days over a 3-month period. On each sampling day, the paired samplers were deployed at three fixed locations and data were analyzed to identify agreement and to examine systematic biases between concentrations measured by these samplers. Thirty-six paired gravimetric samples were analyzed; insignificant, unsubstantial differences between concentrations were identified between the two samplers (p = 0.16; mean difference 0.03 mg/m 3 ). Forty-four paired samples were available for endotoxin analysis, and a significant (p = 0.001) difference in endotoxin concentration was identified: the prototype sampler, on average, had 120 EU/m 3 more endotoxin than did the IOM samples. Since the same gravimetric samples were analyzed for endotoxin content, the endotoxin difference is likely attributable to differences in endotoxin extraction. The prototype's disposable thin-film polycarbonate capsule was included with the filter in the 1-hr extraction procedure while the internal plastic cassette of the IOM required a rinse procedure that is susceptible to dust losses. Endotoxin concentrations measured with standard plastic IOM inserts that follow this rinsing procedure may underestimate the true endotoxin exposure concentrations. The maximum concentrations in the study (1.55 mg/m 3 gravimetric, 2328 EU/m 3 endotoxin) were lower than other agricultural or industrial environments. Future work should explore the performance of the prototype sampler in dustier environments, where concentrations approach particulates not otherwise

  18. Development of automatic smear testing sampler for radioactive contamination of floor in nuclear power plant

    International Nuclear Information System (INIS)

    Nozawa, Katsuro; Hashimoto, Hiroshi; Shinohara, Yohtaro; Iwaki, Kiyotaka

    1980-01-01

    The floor contamination with radioactive substances in the controlled area of nuclear power stations is strictly controlled, and it is tested by the smear method, wiping the contaminants on floors with filter papers or cloths and measuring the radioactive intensity to obtain contamination density. The works are very laborious, therefore the automatic smear sampler was developed. Simple operation, shortening of time required for wiping, constant and high efficiency of wiping, and easy numbering of samples were the aims in the development. The method of wiping, the mechanisms of wiping, cloth feeding and running, the surface pressure at the time of wiping, the number of times of wiping and required motor torque were studied. The outline of the developed sampler is explained. The performance of the sampler was compared with manual wiping. The efficiency of wiping with the sampler was 92%, assuming manual wiping as 100. Difference was not observed between careful manual wiping and the wiping with the sampler, therefore it was confirmed that this automatic floor smear sampler can be put in practical use. By conventional manual sampling, the maximum limit was about 400 samples/man-day, but when this sampler is used, about 1000 samples/sampler-day is possible. At present, this sampler is operated in Hamaoka Nuclear Power Station. (Kako, I.)

  19. A constant flow filter air sampler for workplace environments

    International Nuclear Information System (INIS)

    Parulian, A.; Rodgers, J.C.; McFarland, A.R.

    1996-01-01

    A filter air sampler has been developed for sampling radionuclide aerosol particles form the workplace environment. It provides easy filter changing, constant flow sampling, and a visual display to indicate proper operation. An experimental study was conducted to characterize the collection efficiency of the sampler as affected by variations in room air velocity, particle size, sampling flow rate, inlet geometry, and inlet orientation to the free stream. Tests were carried out in a wing tunnel at velocities between 0.3 m s -1 and 2.0 m s -1 , which is a range that covers anticipated velocities in the typical highly ventilated workplace environment of a nuclear facility. Nearly monodisperse aerosols with sizes between 5 and 20 μm aerodynamic diameter were sampled at flow rates between 28.3 and 84.9 L min -1 . Inlet orientations of 0 degree, 90 degree, and 180 degree from the horizontal were selected for evaluation. When the sampler was oriented at 0 degree over various ranges of free stream velocities, sampling flow rates and particle sizes, the transmission efficiency of aerosol was typically greater than 95%. The transmission efficiencies varied form 80% to 106% for 10-μm aerodynamic diameter particles over the previously noted range of free stream velocities and inlet orientations. Uniformity of deposits of 10 μm aerodynamic diameter particles on collection filters was examined for a sampling rate of 57 L min -1 , a sampler orientation of 90 degree into the wind and wind speeds of 0.3-2 m s -1 . The coefficients of variation for the areal density of the deposits ranged from 6.1% to 37.2%. A miniature critical flow venturi with a constant sampling flow rate of 57 L min -1 was developed for application to the new filter air sampler. It was demonstrated that the performance of the new filter air sampler is quite acceptable over a wide range of conditions. 31 refs., 8 figs., 1 tab

  20. Field performance evaluation during fog-dominated wintertime of a newly developed denuder-equipped PM1 sampler.

    Science.gov (United States)

    Singh, Dharmendra Kumar; Lakshay; Gupta, Tarun

    2014-03-01

    This study presents the performance evaluation of a novel denuder-equipped PM1 (particles having aerodynamic diameter less than 1 μm) sampler, tested during fog-dominated wintertime, in the city of Kanpur, India. One PM1 sampler and one denuder-equipped PM1 sampler were co-located to collect ambient PM1 for 25 days. The mean PM1 mass concentration measured on foggy days with the PM1 sampler and the denuder-equipped PM1 sampler was found to be 165.95 and 135.48 μg/m(3), respectively. The mean PM1 mass concentration measured on clear days with the PM1 sampler and the denuder-equipped PM1 sampler was observed to be 159.66 and 125.14 μg/m(3), respectively. The mass concentration with denuder-fitted PM1 sampler for both foggy and clear days was always found less than the PM1 sampler. The same drift was observed in the concentrations of water-soluble ions and water-soluble organic carbon (WSOC). Moreover, it was observed that the use of denuder leads to a significant reduction in the PM positive artifact. The difference in the concentration of chemical species obtained by two samplers indicates that the PM1 sampler without denuder had overestimated the concentrations of chemical species in a worst-case scenario by almost 40 %. Denuder-fitted PM1 sampler can serve as a useful sampling tool in estimating the true values for nitrate, ammonium, potassium, sodium and WSOC present in the ambient PM.

  1. Development of a personal multi-pollutant exposure sampler for particulate matter and criteria gases

    Energy Technology Data Exchange (ETDEWEB)

    Chang, I.T.; Sarnat, J.; Wolfson, J.M.; Rojas-Bracho, L.; Suh, H.H.; Koutrakis, P. [Harvard Univ., Boston, MA (United States). School of Public Health

    1999-12-01

    A novel personal sampler is reported which allows simultaneous measurement of PM{sub 2,5}, and PM{sub 10}, ozone, nitrogen dioxide, and sulfur dioxide. This method combines previously used samplers for personal mass measurement with passive samplers for criteria gases and uses a single pump. Preliminarily results are reported for laboratory chamber tests and field comparisons with reference methods for both mass and criteria gases. These results demonstrate the suitability of this sampler of exposure assessment studies. (authors)

  2. A cheap and simple passive sampler using silicone rubber for the ...

    African Journals Online (AJOL)

    caffeine, personal care products, pharmaceuticals, pesticides and polycyclic aromatic hydrocarbons. Keywords: passive sampler, silicone rubber (PDMS) tubing, GCxGC-TOFMS, ..... concentrations may be derived by using performance reference compounds to determine in situ passive sampler sampling rates followed by ...

  3. New transformation mechanism for a zinc-blende to rocksalt phase transformation in MgS

    International Nuclear Information System (INIS)

    Durandurdu, Murat

    2009-01-01

    The stability of the zinc-blende structured MgS is studied using a constant pressure ab initio molecular dynamics technique. A phase transition into a rocksalt structure is observed through the simulation. The zinc-blende to rocksalt phase transformation proceeds via two rhombohedral intermediate phases within R3m (No:160) and R3-barm (No:166) symmetries and does not involve any bond breaking. This mechanism is different from the previously observed mechanism in molecular dynamics simulations. (fast track communication)

  4. A directional passive air sampler for monitoring polycyclic aromatic hydrocarbons (PAHs) in air mass

    International Nuclear Information System (INIS)

    Tao, S.; Liu, Y.N.; Lang, C.; Wang, W.T.; Yuan, H.S.; Zhang, D.Y.; Qiu, W.X.; Liu, J.M.; Liu, Z.G.; Liu, S.Z.; Yi, R.; Ji, M.; Liu, X.X.

    2008-01-01

    A passive air sampler was developed for collecting polycyclic aromatic hydrocarbons (PAHs) in air mass from various directions. The airflow velocity within the sampler was assessed for its responses to ambient wind speed and direction. The sampler was examined for trapped particles, evaluated quantitatively for influence of airflow velocity and temperature on PAH uptake, examined for PAH uptake kinetics, calibrated against active sampling, and finally tested in the field. The airflow volume passing the sampler was linearly proportional to ambient wind speed and sensitive to wind direction. The uptake rate for an individual PAH was a function of airflow velocity, temperature and the octanol-air partitioning coefficient of the PAH. For all PAHs with more than two rings, the passive sampler operated in a linear uptake phase for three weeks. Different PAH concentrations were obtained in air masses from different directions in the field test. - A novel directional passive air sampler was developed and tested for monitoring PAHs in air masses from different directions

  5. Microfluidic Air Sampler for Highly Efficient Bacterial Aerosol Collection and Identification.

    Science.gov (United States)

    Bian, Xiaojun; Lan, Ying; Wang, Bing; Zhang, Yu Shrike; Liu, Baohong; Yang, Pengyuan; Zhang, Weijia; Qiao, Liang

    2016-12-06

    The early warning capability of the presence of biological aerosol threats is an urgent demand in ensuing civilian and military safety. Efficient and rapid air sample collection in relevant indoor or outdoor environment is a key step for subsequent analysis of airborne microorganisms. Herein, we report a portable battery-powered sampler that is capable of highly efficient bioaerosol collection. The essential module of the sampler is a polydimethylsiloxane (PDMS) microfluidic chip, which consisted of a 3-loop double-spiral microchannel featuring embedded herringbone and sawtooth wave-shaped structures. Vibrio parahemolyticus (V. parahemolyticus) as a model microorganism, was initially employed to validate the bioaerosol collection performance of the device. Results showed that the sampling efficacy reached as high as >99.9%. The microfluidic sampler showed greatly improved capturing efficiency compared with traditional plate sedimentation methods. The high performance of our device was attributed to the horizontal inertial centrifugal force and the vertical turbulence applied to airflow during sampling. The centrifugation field and turbulence were generated by the specially designed herringbone structures when air circulated in the double-spiral microchannel. The sawtooth wave-shaped microstructure created larger specific surface area for accommodating more aerosols. Furthermore, a mixture of bacterial aerosols formed by V. parahemolyticus, Listeria monocytogenes, and Escherichia coli was extracted by the microfluidic sampler. Subsequent integration with mass spectrometry conveniently identified the multiple bacterial species captured by the sampler. Our developed stand-alone and cable-free sampler shows clear advantages comparing with conventional strategies, including portability, easy-to-use, and low cost, indicating great potential in future field applications.

  6. Reuter Centrifugal Air Sampler: Measurement of Effective Airflow Rate and Collection Efficiency

    OpenAIRE

    Macher, J. M.; First, M. W.

    1983-01-01

    Incorrect calculation of effective air sampling rate and disregard of differences in collection efficiency among samplers can lead to false conclusions about the usefulness of samplers for measuring concentrations of airborne microorganisms.

  7. Computational fluid dynamics (CFD) simulation of a newly designed passive particle sampler.

    Science.gov (United States)

    Sajjadi, H; Tavakoli, B; Ahmadi, G; Dhaniyala, S; Harner, T; Holsen, T M

    2016-07-01

    In this work a series of computational fluid dynamics (CFD) simulations were performed to predict the deposition of particles on a newly designed passive dry deposition (Pas-DD) sampler. The sampler uses a parallel plate design and a conventional polyurethane foam (PUF) disk as the deposition surface. The deposition of particles with sizes between 0.5 and 10 μm was investigated for two different geometries of the Pas-DD sampler for different wind speeds and various angles of attack. To evaluate the mean flow field, the k-ɛ turbulence model was used and turbulent fluctuating velocities were generated using the discrete random walk (DRW) model. The CFD software ANSYS-FLUENT was used for performing the numerical simulations. It was found that the deposition velocity increased with particle size or wind speed. The modeled deposition velocities were in general agreement with the experimental measurements and they increased when flow entered the sampler with a non-zero angle of attack. The particle-size dependent deposition velocity was also dependent on the geometry of the leading edge of the sampler; deposition velocities were more dependent on particle size and wind speeds for the sampler without the bend in the leading edge of the deposition plate, compared to a flat plate design. Foam roughness was also found to have a small impact on particle deposition. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. A Pilot Study: The UNC Passive Aerosol Sampler in a Working Environment.

    Science.gov (United States)

    Shirdel, Mariam; Wingfors, Håkan; Andersson, Britt M; Sommar, Johan N; Bergdahl, Ingvar A; Liljelind, Ingrid E

    2017-10-01

    Dust is generally sampled on a filter using air pumps, but passive sampling could be a cost-effective alternative. One promising passive sampler is the University of North Carolina passive aerosol sampler (UNC sampler). The aim of this study is to characterize and compare the UNC sampler's performance with PM10 and PM2.5 impactors in a working environment. Area sampling was carried out at different mining locations using UNC samplers in parallel with PM2.5 and PM10 impactors. Two different collection surfaces, polycarbonate (PC) and carbon tabs (CT), were employed for the UNC sampling. Sampling was carried out for 4-25 hours. The UNC samplers underestimated the concentrations compared to PM10 and PM2.5 impactor data. At the location with the highest aerosol concentration, the time-averaged mean of PC showed 24% and CT 35% of the impactor result for PM2.5. For PM10, it was 39% with PC and 58% with CT. Sample blank values differed between PC and CT. For PM2.5, PC blank values were ~7 times higher than those of CT, but only 1.8 times higher for PM10. The blank variations were larger for PC than for CT. Particle mass concentrations appear to be underestimated by the UNC sampler compared to impactors, more so for PM2.5 than for PM10. CT may be preferred as a collection surface because the blank values were lower and less variable than for PC. Future validations in the working environment should include respirable dust sampling. © The Author 2017. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.

  9. Evaluation of passive samplers for the collection of dissolved organic matter in streams.

    Science.gov (United States)

    Warner, Daniel L; Oviedo-Vargas, Diana; Royer, Todd V

    2015-01-01

    Traditional sampling methods for dissolved organic matter (DOM) in streams limit opportunities for long-term studies due to time and cost constraints. Passive DOM samplers were constructed following a design proposed previously which utilizes diethylaminoethyl (DEAE) cellulose as a sampling medium, and they were deployed throughout a temperate stream network in Indiana. Two deployments of the passive samplers were conducted, during which grab samples were frequently collected for comparison. Differences in DOM quality between sites and sampling methods were assessed using several common optical analyses. The analyses revealed significant differences in optical properties between sampling methods, with the passive samplers preferentially collecting terrestrial, humic-like DOM. We assert that the differences in DOM composition from each sampling method were caused by preferential binding of complex humic compounds to the DEAE cellulose in the passive samplers. Nonetheless, the passive samplers may provide a cost-effective, integrated sample of DOM in situations where the bulk DOM pool is composed mainly of terrestrial, humic-like compounds.

  10. Overflow type sodium sampler for FBTR circuits

    International Nuclear Information System (INIS)

    Muralidaran, P.; Ganesan, V.; Chandran, K.; Periaswami, G.

    1996-01-01

    Obtaining a representative sample is crucial for getting reliable results in sodium analysis. Sampling liquid sodium reliability is complicated since impurities segregate while cooling. Selective sorption of certain elements calls for use of different crucible materials for various sodium impurities. Sampling methods currently in use such as flow through sampling and dip sampling are not the proper methods as they can not take care of the above problems. An overflow type sampler where the entire sample contained in a crucible can be used for analysis thus obviating problems due to segregation has been developed for use in Fast Breeder Test Reactor (FBTR). This report describes the construction and operation of this sampler. (author)

  11. Sampling Efficiency and Performance of Selected Thoracic Aerosol Samplers.

    Science.gov (United States)

    Görner, Peter; Simon, Xavier; Boivin, Alexis; Bau, Sébastien

    2017-08-01

    Measurement of worker exposure to a thoracic health-related aerosol fraction is necessary in a number of occupational situations. This is the case of workplaces with atmospheres polluted by fibrous particles, such as cotton dust or asbestos, and by particles inducing irritation or bronchoconstriction such as acid mists or flour dust. Three personal and two static thoracic aerosol samplers were tested under laboratory conditions. Sampling efficiency with respect to particle aerodynamic diameter was measured in a horizontal low wind tunnel and in a vertical calm air chamber. Sampling performance was evaluated against conventional thoracic penetration. Three of the tested samplers performed well, when sampling the thoracic aerosol at nominal flow rate and two others performed well at optimized flow rate. The limit of flow rate optimization was found when using cyclone samplers. © The Author 2017. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.

  12. Evaluating the Relationship between Equilibrium Passive Sampler Uptake and Aquatic Organism Bioaccumulation,

    Science.gov (United States)

    Objectives. This review evaluates passive sampler uptake of hydrophobic organic contaminants (HOCs) in water column and interstitial water exposures as a surrogate for organism bioaccumulation. Approach/Activities. Fifty-five studies were found where both passive sampler uptake...

  13. Monitoring of urban particulate using an electret-based passive sampler

    Energy Technology Data Exchange (ETDEWEB)

    Thorpe, A.; Hemingway, M.A.; Brown, R.C.

    1999-11-01

    Site sampling trials have been carried out in the urban environment in order to assess the usefulness of a passive sampling device, originally developed for personal monitoring of airborne dust levels in industry. The sampling element is a small disc of elect material (polymer carrying a permanent electric charge) within a metal frame weighing approximately 15 g. The sampler is designed to capture particles by electrostatic attraction, in which case the capture rate depends on their electrical mobility but is independent of the rate at which air flows past the device. Passive samplers, along with miniaturized cascade impactors, have been exposed to urban particulate for periods of up to 28 days in locations with significant different levels of airborne pollution. The cascade impactor data enabled good estimates to be made of PM{sub 10} and PMN{sub 2.5} levels, and data from the passive sampler correlated with the total dust sampled by the impactor and with both the size fractions, that with the PM{sub 10} being better. Too few data have yet been obtained for its accuracy to be established, but it is unlikely that it will approach that of pumped samplers. It has been shown to be potentially useful for multiple, simultaneous site sampling and for monitoring personal environmental exposure situations in which dispensing with a power source is particularly useful. Being small, the sampler is easy to hide or camouflage, and because it is cheap, its loss or damage is not a serious matter.

  14. UWB Sampler for Wireless Communications and Radar

    National Research Council Canada - National Science Library

    Han, Jeongwoo; Nguyen, Cam

    2005-01-01

    An ultra wideband (UWB) sampler, realized using step recovery and Schottky diodes on coplanar waveguide, coplanar strips and slotlines, has been developed for UWB wireless communications and radar systems...

  15. Improving the UNC Passive Aerosol Sampler Model Based on Comparison with Commonly Used Aerosol Sampling Methods.

    Science.gov (United States)

    Shirdel, Mariam; Andersson, Britt M; Bergdahl, Ingvar A; Sommar, Johan N; Wingfors, Håkan; Liljelind, Ingrid E

    2018-03-12

    In an occupational environment, passive sampling could be an alternative to active sampling with pumps for sampling of dust. One passive sampler is the University of North Carolina passive aerosol sampler (UNC sampler). It is often analysed by microscopic imaging. Promising results have been shown for particles above 2.5 µm, but indicate large underestimations for PM2.5. The aim of this study was to evaluate, and possibly improve, the UNC sampler for stationary sampling in a working environment. Sampling was carried out at 8-h intervals during 24 h in four locations in an open pit mine with UNC samplers, respirable cyclones, PM10 and PM2.5 impactors, and an aerodynamic particle sizer (APS). The wind was minimal. For quantification, two modifications of the UNC sampler analysis model, UNC sampler with hybrid model and UNC sampler with area factor, were compared with the original one, UNC sampler with mesh factor derived from wind tunnel experiments. The effect of increased resolution for the microscopic imaging was examined. Use of the area factor and a higher resolution eliminated the underestimation for PM10 and PM2.5. The model with area factor had the overall lowest deviation versus the impactor and the cyclone. The intraclass correlation (ICC) showed that the UNC sampler had a higher precision and better ability to distinguish between different exposure levels compared to the cyclone (ICC: 0.51 versus 0.24), but lower precision compared to the impactor (PM10: 0.79 versus 0.99; PM2.5: 0.30 versus 0.45). The particle size distributions as calculated from the different UNC sampler analysis models were visually compared with the distributions determined by APS. The distributions were obviously different when the UNC sampler with mesh factor was used but came to a reasonable agreement when the area factor was used. High resolution combined with a factor based on area only, results in no underestimation of small particles compared to impactors and cyclones and a

  16. Performances of an atmospheric tritium sampler and its application

    International Nuclear Information System (INIS)

    Inoue, Yoshikazu; Kahn, B.; Carter, M.W.

    1983-01-01

    A sampling system for atmospheric tritium in the form of water vapor, hydrogen and hydrocarbons was designed and built. The air was passed first through molecular sieve which adsorbed water vapor, then over palladium catalyst which oxidized hydrogen and adsorbed resulting water in situ, and finally over hot Hopcalite catalyst, which oxidized hydrocarbons and the resulting water was adsorbed on a following molecular sieve column. Three water samples were extracted from adsorbers and their tritium contents were measured by liquid scintillation counting. Performances of this sampler were examined for retrieval of tritiated water from molecular sieve, oxidation of hydrogen on palladium catalyst and oxidation of methane on Hopcalite. The portable sampler was applied to analyze tritium in a duct air of a heavy water moderated research reactor. More than 99% of total tritium was in vapor form. Trace amounts of tritiated hydrogen and hydrocarbon were also detected. This tritium sampler is applicable to detect all of atmospheric tritium as high as ten times of ambient levels. (author)

  17. The orientation-averaged aspiration efficiency of IOM-like personal aerosol samplers mounted on bluff bodies.

    Science.gov (United States)

    Paik, Samuel Y; Vincent, James H

    2004-01-01

    This paper describes two sets of experiments that were intended to characterize the orientation-averaged aspiration efficiencies of IOM samplers mounted on rotating bluff bodies. IOM samplers were mounted on simplified, three-dimensional rectangular bluff bodies that were rotated horizontally at a constant rate. Orientation-averaged aspiration efficiencies (A360) were measured as a function of Stokes' number (St), velocity ratio (R) and dimension ratio (r). Aspiration efficiency (A) is the efficiency with which particles are transported from the ambient air into the body of a sampler, and A360 is A averaged over all orientations to the wind. St is a dimensionless variable that represents particle inertia, R is the ratio of the air velocity in the freestream and that at the plane of the sampler's entry orifice, and r is the ratio of the sampler's orifice diameter and the bluff body's width. The first set of experiments were instrumental in establishing a hierarchy of effects on orientation-averaged A. It was clear that compared to r, St had a much larger influence on A. It was also clear, however, that the effects of St were overpowered by the effects of R in many cases. As concluded in previous studies, R and St were considered the most important factors in determining A, even for A360. The second set of experiments investigated A360 of IOM samplers for a much wider range of r than examined in previous research. Two important observations were made from the experimental results. One was that the A360 of IOM samplers, as a function of St, did not change for an r-range of 0.066-0.4. This meant that an IOM sampler mounted on a near life-size mannequin would measure the same aerosol concentration as one not mounted on anything. The second observation was that the aspiration efficiency curve of the IOM sampler was close to the inhalability curve. This gave further evidence that the bluff body did not play a major role in influencing A360, as the IOM samplers, in these

  18. WHATS-3: An improved flow-through multi-bottle fluid sampler for deep-sea geofluid research

    Science.gov (United States)

    Miyazaki, Junichi; Makabe, Akiko; Matsui, Yohei; Ebina, Naoya; Tsutsumi, Saki; Ishibashi, Jun-ichiro; Chen, Chong; Kaneko, Sho; Takai, Ken; Kawagucci, Shinsuke

    2017-06-01

    Deep-sea geofluid systems, such as hydrothermal vents and cold seeps, are key to understanding subseafloor environments of Earth. Fluid chemistry, especially, provides crucial information towards elucidating the physical, chemical and biological processes that occur in these ecosystems. To accurately assess fluid and gas properties of deep-sea geofluids, well-designed pressure-tight fluid samplers are indispensable and as such they are important assets of deep-sea geofluid research. Here, the development of a new flow-through, pressure-tight fluid sampler capable of four independent sampling events (two subsamples for liquid and gas analyses from each) is reported. This new sampler, named WHATS-3, is a new addition to the WHATS-series samplers and a major upgrade from the previous WHATS-2 sampler with improvements in sample number, valve operational time, physical robustness, and ease of maintenance. Routine laboratory-based pressure tests proved that it is suitable for operation up to 35 MPa pressure. Successful field tests of the new sampler were also carried out in five hydrothermal fields, two in Indian Ocean and three in Okinawa Trough (max. depth 3,300 m). Relations of Mg and major ion species demonstrated bimodal mixing trends between a hydrothermal fluid and seawater, confirming the high-quality of fluids sampled. The newly developed WHATS-3 sampler is well-balanced in sampling capability, field usability, and maintenance feasibility, and can serve as one of the best geofluid samplers available at present to conduct efficient research of deep-sea geofluid systems.

  19. The suitability of the IOM foam sampler for bioaerosol sampling in Occupational Environments.

    Science.gov (United States)

    Haatainen, Susanna; Laitinen, Juha; Linnainmaa, Markku; Reponen, Tiina; Kalliokoski, Pentti

    2010-01-01

    Concurrent samples were collected with Andersen and IOM foam samplers to determine whether if the IOM foam sampler can be applied to collect culturable microorganisms. Two different kinds of aerosols were studied: peat dust in a power plant and mist from coolant fluid aerosolized during grinding of blades and rollers in a paper mill. In the power plant, the concentrations of fungi were 2-3 times higher in the IOM samples than in the Andersen samples. However, more fungal genera were identified in the latter case. The methods yielded similar concentrations of bacteria and actinobacteria in the power plant. On the other hand, the performance of the IOM foam sampler was very poor in the paper mill, where stress-sensitive gram-negative bacteria dominated; low concentration of bacteria was detected in only one IOM sample even though the concentration of bacteria often exceeded even the upper detection limit in the Andersen impactor samples. It could be concluded that the IOM foam sampler performs quite well for collecting inhalable fungi and actinobacteria. However, the Andersen sampler provides better information on fungal genera and concentrations of gram-negative bacteria. Personal sampling with the IOM foam sampler provided an important benefit in the power plant, where the concentration ratio of personal to stationary samples was much higher for bacteria than for inhalable or respirable dust.

  20. Field trials of an electret based passive dust sampler in coal mines

    Energy Technology Data Exchange (ETDEWEB)

    Hemingway, M.A.; Brown, R.C.; Arthur, J. [Health and Safety Laboratory, Sheffield (United Kingdom)

    1997-12-31

    An electret-based passive dust sampler has been developed by the Health and Safety Laboratory, UK. The device consists of a small disc of electret (polymer holding a permanent electric charge) held between earthen plates, and it acts by attaching charged dust particles to itself. The device does not require a pump and its rate of sampling is independent of external air velocity, provided that the velocity exceeds a low limiting value. Experiments have been carried out in two coal mines. In each experiment two passive sampler were mounted alongside an MRE sampler at the statutory sampling point in the return roadway. Both passive samplers were mounted vertically but in one the plane of the electret was parallel to the air flow and in the other it was perpendicular. The result obtained from the first mine showed a good correlation between gravimetric estimates of dust concentration obtained with the passive samplers and respirable dust concentrations obtained with MRE. The correlation between the two sets of results at the second mine was not quite as good as those of the first, but was reasonable. In no instance was any significant difference observed between samples obtained from pairs of passive samples in different orientations. 8 refs., 5 figs., 2 tabs.

  1. Short-term diffusive sampler for nitrogen dioxide monitoring in epidemiology

    International Nuclear Information System (INIS)

    Michaud, J.P.; Quackenboss, J.

    1991-01-01

    An automated timed exposure diffusive sampler (TEDS) for sampling nitrogen dioxide (NO 2 ) was developed for use in epidemiological studies. The TEDS sequentially exposes four passive sampling devices (PSD) by microprocessor controlled valves while a pump and air flow guide prevent sampler starvation. Two TEDS units and two portable, real-time NO 2 monitors were tested for accuracy, precision, sensitivity, and linearity of response. The accuracy of the TEDS was within 10 percent of the means of the measured values. The TEDS sensitivity was 20 to 30 ppb-hour for NO 2 . Co-location of the TEDS with a chemiluminescent NO x monitor (EPA reference method) showed a similar responses to ambient NO 2 . TEDS allows better time resolution than traditional diffusive samplers (i.e., Palmes tube) while sharing their ability to sample a variety of gases

  2. Fluidic Sampler. Tanks Focus Area. OST Reference No. 2007

    International Nuclear Information System (INIS)

    1999-01-01

    Problem Definition; Millions of gallons of radioactive and hazardous wastes are stored in underground tanks across the U.S. Department of Energy (DOE) complex. To manage this waste, tank operators need safe, cost-effective methods for mixing tank material, transferring tank waste between tanks, and collecting samples. Samples must be collected at different depths within storage tanks containing various kinds of waste including salt, sludge, and supernatant. With current or baseline methods, a grab sampler or a core sampler is inserted into the tank, waste is maneuvered into the sample chamber, and the sample is withdrawn from the tank. The mixing pumps in the tank, which are required to keep the contents homogeneous, must be shut down before and during sampling to prevent airborne releases. These methods are expensive, require substantial hands-on labor, increase the risk of worker exposure to radiation, and often produce nonrepresentative and unreproducible samples. How It Works: The Fluidic Sampler manufactured by AEA Technology Engineering Services, Inc., enables tank sampling to be done remotely with the mixing pumps in operation. Remote operation minimizes the risk of exposure to personnel and the possibility of spills, reducing associated costs. Sampling while the tank contents are being agitated yields consistently homogeneous, representative samples and facilitates more efficient feed preparation and evaluation of the tank contents. The above-tank portion of the Fluidic Sampler and the replacement plug and pipework that insert through the tank top are shown.

  3. Project R43.106: Field trails of a passive dust sampler in mines: Final report

    Energy Technology Data Exchange (ETDEWEB)

    Hemingway, M. [Health and Safety Laboratory, Sheffield (United Kingdom). Environmental Measurement Groups

    1999-12-01

    Electret based passive dust samplers developed by the project were tested in four collieries in the United Kingdom and compared with MRE gravimetric site samplers (Casella type 113A) and CIP10 samplers (Capteur Indivuel de Poussiere 10 made by Arelco, France). Results of site sampling and personal sampling was assessed according to the draft-CFB standard (1998). The sampler did not satisfy the CEN criteria when results from all the collieries were analysed and therefore a general calibration function suitable for all mines could not be used. In the severe conditions of the coal mines, 62% of the passive samplers failed because the electrets lost more than 70% of their initial surface charge. Work is recommended on improving the charge stability of the electrets. 7 refs., 6 figs., 1 app.

  4. Mobile dynamic passive sampling of trace organic compounds: Evaluation of sampler performance in the Danube River.

    Science.gov (United States)

    Vrana, Branislav; Smedes, Foppe; Allan, Ian; Rusina, Tatsiana; Okonski, Krzysztof; Hilscherová, Klára; Novák, Jiří; Tarábek, Peter; Slobodník, Jaroslav

    2018-03-29

    A "dynamic" passive sampling (DPS) device, consisting of an electrically driven large volume water pumping device coupled to a passive sampler exposure cell, was designed to enhance the sampling rate of trace organic compounds. The purpose of enhancing the sampling rate was to achieve sufficient method sensitivity, when the period available for sampling is limited to a few days. Because the uptake principle in the DPS remains the same as for conventionally-deployed passive samplers, free dissolved concentrations can be derived from the compound uptake using available passive sampler calibration parameters. This was confirmed by good agreement between aqueous concentrations of polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs) and hexachlorobenzene (HCB) derived from DPS and conventional caged passive sampler. The DPS device enhanced sampling rates of compounds that are accumulated in samplers under water boundary layer control (WBL) more than five times compared with the conventionally deployed samplers. The DPS device was deployed from a ship cruising downstream the Danube River to provide temporally and spatially integrated concentrations. A DPS-deployed sampler with surface area of 400cm 2 can reach sampling rates up to 83Ld -1 . The comparison of three passive samplers made of different sorbents and co-deployed in the DPS device, namely silicone rubber (SR), low density polyethylene (LDPE) and SDB-RPS Empore™ disks showed a good correlation of surface specific uptake for compounds that were sampled integratively during the entire exposure period. This provided a good basis for a cross-calibration between the samplers. The good correlation of free dissolved PAHs, PCBs and HCB concentration estimates obtained using SR and LDPE confirmed that both samplers are suitable for the identification of concentration gradients and trends in the water column. We showed that the differences in calculated aqueous concentrations between sampler types

  5. Europa Drum Sampler (EDuS), Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The main objective of the proposed work is to develop a robust and effective sample acquisition system for the Europa lander called the Europa Drum Sampler (EDuS)....

  6. WHATS-3: An Improved Flow-Through Multi-bottle Fluid Sampler for Deep-Sea Geofluid Research

    Directory of Open Access Journals (Sweden)

    Junichi Miyazaki

    2017-06-01

    Full Text Available Deep-sea geofluid systems, such as hydrothermal vents and cold seeps, are key to understanding subseafloor environments of Earth. Fluid chemistry, especially, provides crucial information toward elucidating the physical, chemical, and biological processes that occur in these ecosystems. To accurately assess fluid and gas properties of deep-sea geofluids, well-designed pressure-tight fluid samplers are indispensable and as such they are important assets of deep-sea geofluid research. Here, the development of a new flow-through, pressure-tight fluid sampler capable of four independent sampling events (two subsamples for liquid and gas analyses from each is reported. This new sampler, named WHATS-3, is a new addition to the WHATS-series samplers and a major upgrade from the previous WHATS-2 sampler with improvements in sample number, valve operational time, physical robustness, and ease of maintenance. Routine laboratory-based pressure tests proved that it is suitable for operation up to 35 MPa pressure. Successful field tests of the new sampler were also carried out in five hydrothermal fields, two in Indian Ocean, and three in Okinawa Trough (max. depth 3,300 m. Relations of Mg and major ion species demonstrated bimodal mixing trends between a hydrothermal fluid and seawater, confirming the high quality of fluids sampled. The newly developed WHATS-3 sampler is well-balanced in sampling capability, field usability, and maintenance feasibility, and can serve as one of the best geofluid samplers available at present to conduct efficient research of deep-sea geofluid systems.

  7. Comparative evaluation of three impactor samplers for measuring airborne bacteria and fungi concentrations.

    Science.gov (United States)

    Méheust, Delphine; Gangneux, Jean-Pierre; Cann, Pierre Le

    2013-01-01

    Portable microbial samplers are useful for detecting microorganisms in the air. However, limited data are available on their performance when sampling airborne biological agents in a routine practice. We compared bacterial and fungal concentrations obtained in field conditions using three impactor samplers with different designs (AES Chemunex Sampl'Air, bioMérieux Air Ideal, and Sartorius AirPort MD8/BACTair). The linearity of mold collection was tested in the range of 100 L to 1000 L, and all the devices had a correlation coefficient higher than 0.95. For optimal comparison of the samplers, we performed experiments in different hospital rooms with varying levels of air biocontamination. Each sampling procedure was repeated to assess reproducibility. No significant difference between the samplers was observed for the mold concentrations on Sabouraud agar, whereas Sampl'Air collected significantly more bacteria on tryptic soy agar than Air Ideal or BACTair at one of the sites. Impactor location in the room was nevertheless associated with the variability observed with the three samplers at the highest microbial concentration levels. On the basis of their performance, autonomy and simplicity of use, these three impactors are suitable for routine indoor evaluation of microbial air contamination.

  8. Comparative performance of two air samplers for monitoring airborne fungal propagules

    Directory of Open Access Journals (Sweden)

    L.G.F. Távora

    2003-05-01

    Full Text Available Many studies have attempted to evaluate the importance of airborne fungi in the development of invasive fungal infection, especially for immunocompromised hosts. Several kinds of instruments are available to quantitate fungal propagule levels in air. We compared the performance of the most frequently used air sampler, the Andersen sampler with six stages, with a portable one, the Reuter centrifugal sampler (RCS. A total of 84 samples were analyzed, 42 with each sampler. Twenty-eight different fungal genera were identified in samples analyzed with the Andersen instrument. In samples obtained with the RCS only seven different fungal genera were identified. The three most frequently isolated genera in samples analyzed with both devices were Penicillium, Aspergillus and Cladophialophora. In areas supplied with a high efficiency particulate air filter, fungal spore levels were usually lower when compared to areas without these filters. There was a significant correlation between total fungal propagule measurements taken with both devices on each sampling occasion (Pearson coefficient = 0.50. However, the Andersen device recovered a broader spectrum of fungi. We conclude that the RCS can be used for quantitative estimates of airborne microbiological concentrations. For qualitative studies, however, this device cannot be recommended.

  9. Chemistry of the sea surface microlayer. 1. Fabrication and testing of the sampler

    Digital Repository Service at National Institute of Oceanography (India)

    Singbal, S.Y.S.; Narvekar, P.V.

    A screen sampler fabricated to study the sea surface microlayer (SML) has been described. The screen sampler was tested in the Mandovi estuary and adjacent waters. Physico-chemical parameters of the subsurface waters from a depth of 25 cm was also...

  10. Evaluating the Relationship between Equilibrium Passive Sampler Uptake and Aquatic Organism Bioaccumulation (IPSW)

    Science.gov (United States)

    This review evaluates passive sampler uptake of hydrophobic organic contaminants (HOCs) as it relates to organism bioaccumulation in the water column and interstitial water. Fifty-five studies were found where both passive samplers and organism bioaccumulation were used to measur...

  11. 40 CFR 53.54 - Test for proper sampler operation following power interruptions.

    Science.gov (United States)

    2010-07-01

    ...) Mean sample flow rate. (i) From the certified measurements (Qref) of the test sampler flow rate... facilitate measurement of sample flow rate at the sampler downtube. (5) Means for creating an additional... pressures and temperatures used in the tests and shall be checked at zero and at least one flow rate within...

  12. Field evaluation of a tailor-made new passive sampler for the determination of NO2 levels in ambient air.

    Science.gov (United States)

    Ozden, Ozlem; Dogeroglu, Tuncay

    2008-07-01

    This study describes the field evaluation of a tailor-made new glass passive sampler developed for the determination of NO(2), based on the collection on triethanolemine (TEA)-coated fibre filter paper. The sampler has been derived from a Palmes design. The overall uncertainty of the sampler was determined by using Griess-Saltzman ASTM D 1607 standard test method as a reference method. The agreement between the results of the passive sampler and the reference method was +/-7.90% with the correlation coefficient of 0.90. Method precision in terms of coefficient of variance (CV) for three simultaneously applied passive samplers was 8.80%. The uptake rate of NO(2) was found to be 2.49 ml/min in a very good agreement with the value calculated from theory (2.63 ml/min). Sampler detection limit was 1.99 microg/m(3) for an exposure period of 1 week and the sampler can be stored safely for a period of up to 6 weeks before exposure. A comparison of the sampler performance was conducted against a commercially available diffusion tube (Gradko diffusion tube). The results from the applied statistical paired t test indicated that there was no significant difference between the performances of two passive samplers (R (2) > 0.90). Also, another statistical comparison was carried out between the dark and transparent glass passive samplers. The results from the dark-colour sampler were higher than that from the transparent sampler (approximately 25%) during the summer season because of the possible photodegradation of NO(2)-TEA complex.

  13. Field comparison of three inhalable samplers (IOM, PGP-GSP 3.5 and Button) for welding fumes.

    Science.gov (United States)

    Zugasti, Agurtzane; Montes, Natividad; Rojo, José M; Quintana, M José

    2012-02-01

    Inhalable sampler efficiency depends on the aerodynamic size of the airborne particles to be sampled and the wind speed. The aim of this study was to compare the behaviour of three personal inhalable samplers for welding fumes generated by Manual Metal Arc (MMA) and Metal Active Gas (MAG) processes. The selected samplers were the ones available in Spain when the study began: IOM, PGP-GSP 3.5 (GSP) and Button. Sampling was carried out in a welding training center that provided a homogeneous workplace environment. The static sampling assembly used allowed the placement of 12 samplers and 2 cascade impactors simultaneously. 183 samples were collected throughout 2009 and 2010. The range of welding fumes' mass concentrations was from 2 mg m(-3) to 5 mg m(-3). The pooled variation coefficients for the three inhalable samplers were less than or equal to 3.0%. Welding particle size distribution was characterized by a bimodal log-normal distribution, with MMADs of 0.7 μm and 8.2 μm. For these welding aerosols, the Button and the GSP samplers showed a similar performance (P = 0.598). The mean mass concentration ratio was 1.00 ± 0.01. The IOM sampler showed a different performance (P IOM and 0.92 ± 0.02 for GSP/IOM. This information is useful to consider the measurements accomplished by the IOM, GSP or Button samplers together, in order to assess the exposure at workplaces over time or to study exposure levels in a specific industrial activity, as welding operations.

  14. Design and experimental evaluation of a new nanoparticle thermophoretic personal sampler

    Energy Technology Data Exchange (ETDEWEB)

    Azong-Wara, Nkwenti; Asbach, Christof, E-mail: asbach@iuta.de; Stahlmecke, Burkhard; Fissan, Heinz; Kaminski, Heinz [Institute of Energy and Environmental Technology (IUTA), Air Quality and Sustainable Nanotechnology Unit (Germany); Plitzko, Sabine [Federal Institute for Occupational Safety and Health (BAuA) (Germany); Bathen, Dieter; Kuhlbusch, Thomas A. J. [Institute of Energy and Environmental Technology (IUTA), Air Quality and Sustainable Nanotechnology Unit (Germany)

    2013-04-15

    A personal sampler that thermophoretically samples particles between a few nanometers and approximately 300 nm has been designed and first prototypes built. The thermal precipitator (TP) is designed to take samples in the breathing zone of a worker in order to determine the personal exposure to airborne nanomaterials. In the sampler, particles are deposited onto silicon substrates that can be used for consecutive electron microscopic (EM) analysis of the particle size distribution and chemical composition of the sampled particles. Due to very homogeneous size-independent particle deposition on a large portion of the substrate, representative samples can be taken for offline analysis. The experimental evaluation revealed a good general agreement with numerical simulations concerning homogeneity of the deposit and a very high correlation (R Superscript-Two = 0.98) of the deposition rate per unit area with number concentrations simultaneously measured with an SMPS for particle sizes between 14 and 305 nm. The samplers' small size of only 45 x 32 Multiplication-Sign 97 mm{sup 3} and low weight of only 140 g make it perfectly suitable as a personal sampler. The power consumption for temperature control and pump is around 1.5 W and can be easily provided by batteries.

  15. Sampling of high amounts of bioaerosols using a high-volume electrostatic field sampler

    DEFF Research Database (Denmark)

    Madsen, A. M.; Sharma, Anoop Kumar

    2008-01-01

    For studies of the biological effects of bioaerosols, large samples are necessary. To be able to sample enough material and to cover the variations in aerosol content during and between working days, a long sampling time is necessary. Recently, a high-volume transportable electrostatic field...... and 315 mg dust (net recovery of the lyophilized dust) was sampled during a period of 7 days, respectively. The sampling rates of the electrostatic field samplers were between 1.34 and 1.96 mg dust per hour, the value for the Gravikon was between 0.083 and 0.108 mg dust per hour and the values for the GSP...... samplers were between 0.0031 and 0.032 mg dust per hour. The standard deviations of replica samplings and the following microbial analysis using the electrostatic field sampler and GSP samplers were at the same levels. The exposure to dust in the straw storage was 7.7 mg m(-3) when measured...

  16. A sampler of useful computational tools for applied geometry, computer graphics, and image processing foundations for computer graphics, vision, and image processing

    CERN Document Server

    Cohen-Or, Daniel; Ju, Tao; Mitra, Niloy J; Shamir, Ariel; Sorkine-Hornung, Olga; Zhang, Hao (Richard)

    2015-01-01

    A Sampler of Useful Computational Tools for Applied Geometry, Computer Graphics, and Image Processing shows how to use a collection of mathematical techniques to solve important problems in applied mathematics and computer science areas. The book discusses fundamental tools in analytical geometry and linear algebra. It covers a wide range of topics, from matrix decomposition to curvature analysis and principal component analysis to dimensionality reduction.Written by a team of highly respected professors, the book can be used in a one-semester, intermediate-level course in computer science. It

  17. An Introduction to the DA-T Gibbs Sampler for the Two-Parameter Logistic (2PL Model and Beyond

    Directory of Open Access Journals (Sweden)

    Gunter Maris

    2005-01-01

    Full Text Available The DA-T Gibbs sampler is proposed by Maris and Maris (2002 as a Bayesian estimation method for a wide variety of Item Response Theory (IRT models. The present paper provides an expository account of the DAT Gibbs sampler for the 2PL model. However, the scope is not limited to the 2PL model. It is demonstrated how the DA-T Gibbs sampler for the 2PL may be used to build, quite easily, Gibbs samplers for other IRT models. Furthermore, the paper contains a novel, intuitive derivation of the Gibbs sampler and could be read for a graduate course on sampling.

  18. Determination of organochlorine pesticides in Indian coastal water using a moored in-situ sampler

    Digital Repository Service at National Institute of Oceanography (India)

    Sarkar, A.; SenGupta, R.

    An attempt has been made to determine the concentration of different organochlorine pesticides in the seawater off the central West Coast of India using an in-situ-sampler. The Seastar in-situ sampler is an instrument, which is designed to pump...

  19. A novel passive water sampler for in situ sampling of antibiotics.

    Science.gov (United States)

    Chen, Chang-Er; Zhang, Hao; Jones, Kevin C

    2012-05-01

    Passive water sampling has several advantages over active methods; it provides time-integrated data, can save on time and cost compared to active methods, and yield high spatial resolution data through co-deployment of simple, cheap units. However, one problem with many sampler designs in current use is that their uptake rates for trace substances of interest are flow-rate dependent, thereby requiring calibration data and other information to enable water concentrations to be derived from the mass per sampler. However, the 'family' of samplers employing the principle of diffusive gradients in thin films (DGT) provides an in situ means of quantitatively measuring labile species in aquatic systems without field calibration. So far, this technique has only been tested and applied in inorganic substances: metals, radionuclides, nutrients, etc. Design and applications of DGT to trace organic contaminants ('o-DGT') would be of widespread interest. This study describes the laboratory testing and performance characteristics of o-DGT, with the antibiotic sulfamethoxazole (SMX) as a model compound and XAD18 as the novel binding agent. o-DGT uptake of SMX increased with time and decreased with diffusion layer thickness, confirming the principle for SMX. XAD18 showed sufficiently high capacity for SMX for routine field applications. o-DGT measurement of SMX was independent of pH (6-9) and ionic strength (0.001-0.1 M) and not affected by flow rate once above static conditions. The diffusion coefficient of SMX in the sampler was measured using an independent diffusion cell and information is presented to allow temperature correction and derivation of aqueous concentrations from deployed samplers. The potential use of o-DGT for in situ measurement of pharmaceutical antibiotics is confirmed by this study and applications are briefly discussed.

  20. Comparison. US P-61 and Delft sediment samplers

    Science.gov (United States)

    Beverage, Joseph P.; Williams, David T.

    1990-01-01

    The Delft Bottle (DB) is a flow-through device designed by the Delft Hydraulic Laboratory (DHL), The Netherlands, to sample sand-sized sediment suspended in streams. The US P-61 sampler was designed by the Federal Interagency Sedimentation Project (FISP) at the St. Anthony Falls Hydraulic Laboratory, Minneapolis, Minnesota, to collect suspended sediment from deep, swift rivers. The results of two point-sampling tests in the United States, the Mississippi River near Vicksburg, Mississippi, in 1983 and the Colorado River near Blythe, California, in 1984, are provided in this report. These studies compare sand-transport rates, rather than total sediment-transport rates, because fine material washes through the DB sampler. In the United States, the commonly used limits for sand-sized material are 0.062 mm to 2.00 mm (Vanoni 1975).

  1. Partitioning of organochlorine pesticides from water to polyethylene passive samplers

    International Nuclear Information System (INIS)

    Hale, Sarah E.; Martin, Timothy J.; Goss, Kai-Uwe; Arp, Hans Peter H.; Werner, David

    2010-01-01

    The mass transfer rates and equilibrium partitioning behaviour of 14 diverse organochlorine pesticides (OCP) between water and polyethylene (PE) passive samplers, cut from custom made PE sheets and commercial polyethylene plastic bags, were quantified. Overall mass transfer coefficients, k O , estimated PE membrane diffusion coefficients, D PE , and PE-water partitioning coefficients, K PE-water, are reported. In addition, the partitioning of three polycyclic aromatic hydrocarbons (PAHs) from water to PE is quantified and compared with literature values. K PE-water values agreed mostly within a factor of two for both passive samplers and also with literature values for the reference PAHs. As PE is expected to exhibit similar sorption behaviour to long-chain alkanes, PE-water partitioning coefficients were compared to hexadecane-water partitioning coefficients estimated with the SPARC online calculator, COSMOtherm and a polyparameter linear free energy relationship based on the Abraham approach. The best correlation for all compounds tested was with COSMOtherm estimated hexadecane-water partitioning coefficients. - The partitioning of organochlorine pesticides between single phase polyethylene passive samplers and water is quantified.

  2. Passive Sampler for Measurements of Atmospheric Nitric Acid Vapor (HNO3 Concentrations

    Directory of Open Access Journals (Sweden)

    Andrzej Bytnerowicz

    2001-01-01

    Full Text Available Nitric acid (HNO3 vapor is an important nitrogenous air pollutant responsible for increasing saturation of forests with nitrogen and direct injury to plants. The USDA Forest Service and University of California researchers have developed a simple and inexpensive passive sampler for monitoring air concentrations of HNO3. Nitric acid is selectively absorbed on 47-mm Nylasorb nylon filters with no interference from particulate NO3-. Concentrations determined with the passive samplers closely corresponded with those measured with the co-located honeycomb annular denuder systems. The PVC protective caps of standardized dimensions protect nylon filters from rain and wind and allow for reliable measurements of ambient HNO3 concentrations. The described samplers have been successfully used in Sequoia National Park, the San Bernardino Mountains, and on Mammoth Mountain in California.

  3. Uncertainties in monitoring of SVOCs in air caused by within-sampler degradation during active and passive air sampling

    Science.gov (United States)

    Melymuk, Lisa; Bohlin-Nizzetto, Pernilla; Prokeš, Roman; Kukučka, Petr; Přibylová, Petra; Vojta, Šimon; Kohoutek, Jiří; Lammel, Gerhard; Klánová, Jana

    2017-10-01

    Degradation of semivolatile organic compounds (SVOCs) occurs naturally in ambient air due to reactions with reactive trace gases (e.g., ozone, NOx). During air sampling there is also the possibility for degradation of SVOCs within the air sampler, leading to underestimates of ambient air concentrations. We investigated the possibility of this sampling artifact in commonly used active and passive air samplers for seven classes of SVOCs, including persistent organic pollutants (POPs) typically covered by air monitoring programs, as well as SVOCs of emerging concern. Two active air samplers were used, one equipped with an ozone denuder and one without, to compare relative differences in mass of collected compounds. Two sets of passive samplers were also deployed to determine the influence of degradation during longer deployment times in passive sampling. In active air samplers, comparison of the two sampling configurations suggested degradation of particle-bound polycyclic aromatic hydrocarbons (PAHs), with concentrations up to 2× higher in the denuder-equipped sampler, while halogenated POPs did not have clear evidence of degradation. In contrast, more polar, reactive compounds (e.g., organophosphate esters and current use pesticides) had evidence of losses in the sampler with denuder. This may be caused by the denuder itself, suggesting sampling bias for these compounds can be created when typical air sampling apparatuses are adapted to limit degradation. Passive air samplers recorded up to 4× higher concentrations when deployed for shorter consecutive sampling periods, suggesting that within-sampler degradation may also be relevant in passive air monitoring programs.

  4. Heavy water leak detection using diffusion sampler

    International Nuclear Information System (INIS)

    Joshi, M.L.; Hussain, S.A.

    1990-01-01

    In the Pressurrised Heavy Water Reactors (PHWRs) detection of the sources of heavy water leaks is importent both for the purpose of radiation hazard control as well as for the reduction of escape/loss of heavy water which, is an expensive nuclear material. This paper describes an application of tritium diffusion sampler for heavy water leak detection. The diffusion sampler comprises an usual tritium counting glass vial with a special orifice. The counting vial has water vapour, deficient in HTO concentration. The HTO present outside diffuses in the vial through the orifice, gets exchanged with water of the wet filter paper kept at the bottom and the moisture in the vial atmosphere which has HTO concentration lower than that outside. This results in continuation of net movement of HTO in the vial. The exchanged tritium is counted in liquid scintillation spectrometer. The method has a sensitivity of 10000 dpm/DAC-h. (author). 2 figs., 2 ta bs

  5. Mechanical reliability evaluation of alternate motors for use in a radioiodine air sampler

    International Nuclear Information System (INIS)

    Bird, S.K.; Huchton, R.L.; Motes, B.G.

    1984-03-01

    Detailed mechanical reliability studies of two alternate motors identified for use in the BNL Air Sampler wer conducted. The two motor types were obtained from Minnesota Electric Technology, Incorporated (MET) and TCS Industries (TCSI). Planned testing included evaluation of motor lifetimes and motor operability under different conditions of temperature, relative humidity, simulated rainfall, and dusty air. The TCSI motors were not lifetime tested due to their poor performance during the temperature/relative humidity tests. While operation on alternating current was satisfactory, on direct current only one of five TCSI motors completed all environmental testing. The MET motors had average lifetimes of 47 hours, 97 hours, and 188 hours, respectively, and exhibited satisfactory operation under all environmental test conditions. Therefore, the MET motor appears to be the better candidate motor for use in the BNL Air Sampler. However, because of the relatively high cost of purchasing and incorporating the MET motor into the BNL Air Sampler System, it is recommended that commercial air sampler systems be evaluated for use instead of the BNL system

  6. A carbon monoxide passive sampler: Research and development needs

    Energy Technology Data Exchange (ETDEWEB)

    Traynor, G.W.; Apte, M.G.; Diamond, R.C.; Woods, A.L.

    1991-11-01

    In rare instances, carbon monoxide (CO) levels in houses can reach dangerously high concentrations, causing adverse health effects ranging from mild headaches to, under extreme conditions, death. Hundreds of fatal accidental carbon monoxide poisonings occur each year primarily due to the indoor operation of motor vehicles, the indoor use of charcoal for cooking, the operation of malfunctioning vented and unvented combustion appliances, and the misuse combustion appliances. Because there is a lack of simple, inexpensive, and accurate field sampling instrumentation, it is difficult for gas utilities and researchers to conduct field research studies designed to quantify the concentrations of CO in residences. Determining the concentration of CO in residences is the first step towards identifying the high risk appliances and high-CO environments which pose health risks. Thus, there exists an urgent need to develop and field-validate a CO-quantifying technique suitable for affordable field research. A CO passive sampler, if developed, could fulfill these requirements. Existing CO monitoring techniques are discussed as well as three potential CO-detection methods for use in a CO passive sampler. Laboratory and field research needed for the development and validation of an effective and cost-efficient CO passive sampler are also discussed.

  7. Wind tunnel evaluation of the RAAMP sampler. Final report

    International Nuclear Information System (INIS)

    Vanderpool, R.W.; Peters, T.M.

    1994-11-01

    Wind tunnel tests of the Department of Energy RAAMP (Radioactive Atmospheric Aerosol Monitoring Program) monitor have been conducted at wind speeds of 2 km/hr and 24 km/hr. The RAAMP sampler was developed based on three specific performance objectives: (1) meet EPA PM10 performance criteria, (2) representatively sample and retain particles larger than 10 microm for later isotopic analysis, (3) be capable of continuous, unattended operation for time periods up to 2 months. In this first phase of the evaluation, wind tunnel tests were performed to evaluate the sampler as a potential candidate for EPA PM10 reference or equivalency status. As an integral part of the project, the EPA wind tunnel facility was fully characterized at wind speeds of 2 km/hr and 24 km/hr in conjunction with liquid test aerosols of 10 microm aerodynamic diameter. Results showed that the facility and its operating protocols met or exceeded all 40 CFR Part 53 acceptance criteria regarding PM10 size-selective performance evaluation. Analytical procedures for quantitation of collected mass deposits also met 40 CFR Part 53 criteria. Modifications were made to the tunnel's test section to accommodate the large dimensions of the RAAMP sampler's instrument case

  8. Development of polyurethane-based passive samplers for ambient monitoring of urban-use insecticides in water.

    Science.gov (United States)

    Liao, Chunyang; Richards, Jaben; Taylor, Allison R; Gan, Jay

    2017-12-01

    Widespread use of insecticides for the control of urban pests such as ants, termites, and spiders has resulted in contamination and toxicity in urban aquatic ecosystems in different regions of the world. Passive samplers are a convenient and integrative tool for in situ monitoring of trace contaminants in surface water. However, the performance of a passive sampler depends closely on its affinity for the target analytes, making passive samplers highly specific to the types of contaminants being monitored. The goal of this study was to develop a passive sampler compatible with a wide range of insecticides, including the strongly hydrophobic pyrethroids and the weakly hydrophobic fipronil and organophosphates. Of six candidate polymeric thin films, polyurethane film (PU) was identified to be the best at enriching the test compounds. The inclusion of stable isotope labeled analogs as performance reference compounds (PRCs) further allowed the use of PU film for pyrethroids under non-equilibrium conditions. The PU sampler was tested in a large aquarium with circulatory water flow, and also deployed at multiple sites in surface streams in southern California. The concentrations of pesticides derived from the PU sampler ranged from 0.5 to 18.5 ng/L, which were generally lower than the total chemical concentration measured by grab samples, suggesting that suspended particles and dissolved organic matter in water rendered them less available. The influence of suspended particles and dissolved organic matter on bioavailability was more pronounced for pyrethroids than for fipronils. The results show that the developed PU film sampler, when coupled with PRCs, may be used for rapid and sensitive in-situ monitoring of a wide range of insecticides in surface water. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. A novel enhanced diffusion sampler for collecting gaseous pollutants without air agitation.

    Science.gov (United States)

    Pan, Xuelian; Zhuo, Shaojie; Zhong, Qirui; Chen, Yuanchen; Du, Wei; Cheng, Hefa; Wang, Xilong; Zeng, Eddy Y; Xing, Baoshan; Tao, Shu

    2018-03-06

    A novel enhanced diffusion sampler for collecting gaseous phase polycyclic aromatic hydrocarbons (PAHs) without air agitation is proposed. The diffusion of target compounds into a sampling chamber is facilitated by continuously purging through a closed-loop flow to create a large concentration difference between the ambient air and the air in the sampling chamber. A glass-fiber filter-based prototype was developed. It was demonstrated that the device could collect gaseous PAHs at a much higher rate (1.6 ± 1.4 L/min) than regular passive samplers, while the ambient air is not agitated. The prototype was also tested in both the laboratory and field for characterizing the concentration gradients over a short distance from the soil surface. The sampler has potential to be applied in other similar situations to characterize the concentration profiles of other chemicals.

  10. The use of passive samplers for monitoring polycyclic aromatic hydrocarbons in ambient air

    International Nuclear Information System (INIS)

    Jacob, J.; Grimmer, G.; Hildebrandt, A.

    1993-01-01

    In this study polycyclic aromatic hydrocarbon (PAH) concentrations of ambient air are compared to those present in leaves, spruce sprouts and in the corresponding soil used as passive samplers. Marked profile alterations were detected in various soil horizons with increasing relative concentrations of higher boiling and decreasing relative concentrations of lower boiling PAH with depth. There is no direct correlation between the absolute PAH masses found in air samples and those collected by passive samplers or detected in corresponding soil samples. Even the PAH profiles differ significantly: they can, however, be correlated by introducing PAH - and sampler-specific factors. The PAH profiles appear to indicate that coal combustion mostly contributes to the PAH air pollution in the FRG. The time course of the concentration of benzo(a)pyrene and benzo(e)pyrene during the past seven years as measured with spruce sprouts as biological passive sampler indicate a significant decrease of the PAH concentration (by a factor of two) in the FRG. First measurements in a clean air area of the Eastern part of the FRG exhibited up to ten times higher PAH concentrations than found in comparable areas of the western part of the country

  11. Evaluation of physical sampling efficiency for cyclone-based personal bioaerosol samplers in moving air environments.

    Science.gov (United States)

    Su, Wei-Chung; Tolchinsky, Alexander D; Chen, Bean T; Sigaev, Vladimir I; Cheng, Yung Sung

    2012-09-01

    The need to determine occupational exposure to bioaerosols has notably increased in the past decade, especially for microbiology-related workplaces and laboratories. Recently, two new cyclone-based personal bioaerosol samplers were developed by the National Institute for Occupational Safety and Health (NIOSH) in the USA and the Research Center for Toxicology and Hygienic Regulation of Biopreparations (RCT & HRB) in Russia to monitor bioaerosol exposure in the workplace. Here, a series of wind tunnel experiments were carried out to evaluate the physical sampling performance of these two samplers in moving air conditions, which could provide information for personal biological monitoring in a moving air environment. The experiments were conducted in a small wind tunnel facility using three wind speeds (0.5, 1.0 and 2.0 m s(-1)) and three sampling orientations (0°, 90°, and 180°) with respect to the wind direction. Monodispersed particles ranging from 0.5 to 10 μm were employed as the test aerosols. The evaluation of the physical sampling performance was focused on the aspiration efficiency and capture efficiency of the two samplers. The test results showed that the orientation-averaged aspiration efficiencies of the two samplers closely agreed with the American Conference of Governmental Industrial Hygienists (ACGIH) inhalable convention within the particle sizes used in the evaluation tests, and the effect of the wind speed on the aspiration efficiency was found negligible. The capture efficiencies of these two samplers ranged from 70% to 80%. These data offer important information on the insight into the physical sampling characteristics of the two test samplers.

  12. Development and evaluation of an ultrasonic personal aerosol sampler.

    Science.gov (United States)

    Volckens, J; Quinn, C; Leith, D; Mehaffy, J; Henry, C S; Miller-Lionberg, D

    2017-03-01

    Assessing personal exposure to air pollution has long proven challenging due to technological limitations posed by the samplers themselves. Historically, wearable aerosol monitors have proven to be expensive, noisy, and burdensome. The objective of this work was to develop a new type of wearable monitor, an ultrasonic personal aerosol sampler (UPAS), to overcome many of the technological limitations in personal exposure assessment. The UPAS is a time-integrated monitor that features a novel micropump that is virtually silent during operation. A suite of onboard environmental sensors integrated with this pump measure and record mass airflow (0.5-3.0 L/min, accurate within 5%), temperature, pressure, relative humidity, light intensity, and acceleration. Rapid development of the UPAS was made possible through recent advances in low-cost electronics, open-source programming platforms, and additive manufacturing for rapid prototyping. Interchangeable cyclone inlets provided a close match to the EPA PM 2.5 mass criterion (within 5%) for device flows at either 1.0 or 2.0 L/min. Battery life varied from 23 to 45 hours depending on sample flow rate and selected filter media. Laboratory tests of the UPAS prototype demonstrate excellent agreement with equivalent federal reference method samplers for gravimetric analysis of PM 2.5 across a broad range of concentrations. © 2016 The Authors. Indoor Air published by John Wiley & Sons Ltd.

  13. Performance Evaluation of Automated Passive Capillary Sampler for Estimating Water Drainage in the Vadose Zone

    Science.gov (United States)

    Passive capillary samplers (PCAPs) are widely used to monitor, measure and sample drainage water under saturated and unsaturated soil conditions in the vadose zone. The objective of this study was to evaluate the performance and accuracy of automated passive capillary sampler for estimating drainage...

  14. Engineering Task Plan for Preparing the Type 4 In Situ Vapor Samplers (ISVS) for Use

    International Nuclear Information System (INIS)

    BOGER, R.M.

    2000-01-01

    The DOE has identified a need to sample vapor space and exhaust ducts of several waste tanks The In-Situ Vapor Sampling (ISVS) Type IV vapor sampling cart has been identified as the appropriate monitoring tool. The ISVS carts have been out of service for a number of years. This ETP outlines the work to be performed to ready the type IV gas sampler for operation Characterization Engineering will evaluate the Type IV gas sampler carts to determine their state of readiness and will proceed to update procedures and equipment documentation to make the sampler operationally acceptable

  15. HTO/HT discriminating samplers constructed for the french experiment on the environmental behaviour of HT

    International Nuclear Information System (INIS)

    Ogram, G.L.

    1988-12-01

    The French Experiment on Environmental Tritium Behaviour was a field experiment carried out to determine the rate of formation of atmospheric HTO from a release of HT to the natural environment. The Canadian Fusion Fuels Technology Project and Ontario Hydro contributed to the project by supplying HTO/HT-discriminating, atmospheric tritium samplers. Each sampler consisted of a molecular-sieve trap to capture HTO followed by a Pd-impregnated molecular-sieve trap to oxidise and collect HT from the same air stream. This method was selected as it provided high sensitivity over short sampling periods and was convenient for field use. Laboratory tests indicated that this system measured HT concentrations reliably, but only achieved limited discrimination between HT and HTO at HTO/HT concentration ratios below 10 -2 to 10 -3 . Small cold traps were therefore operated during the French experiment in addition to the molecular-sieve samplers exhibited much improved discrimination in the field (approaching 10 4 ), possibly due to higher sampling flow rates than used in the laboratory. These results demonstrate that care should be taken in using desiccant-based, HTO/HT-discriminating samplers when the HT concentration is much higher than HTO concentration, and suggest the need to systematically characterize and perhaps improve the performance of discriminating samplers at low HTO/HT ratios

  16. Isokinetic sampler; Amostrador isocinetico

    Energy Technology Data Exchange (ETDEWEB)

    Andrade, Luis Cesar C. de; Santos, Antonio Carlos dos [PETROBRAS Transporte S.A. (TRANSPETRO), Rio de Janeiro, RJ (Brazil); Barrio, Lara B.A. del [AZ Armaturen do Brasil Ltda., Itatiba, SP (Brazil); Silva, Claudio B. da C. e; Silva, Ricardo R. da [PETROBRAS, Rio de Janeiro, RJ (Brazil). Centro de Pesquisas

    2005-07-01

    The Center of Research Leopoldo A. Miguez de Melo - CENPES - in association with AZ Armaturen Company do Brasil and TRANSPETRO developed and tested an Isokinetic sampler. This work presents the sampling principles and the results and performance of the tests realized in the 'Sitio de Testes de Atalaia' and in one of the terminals of bunker transfer of TRANSPETRO - 'Terminal Aquaviario da Baia de Guanabara'. In the 'Sitio de Testes' the products used were oil and water with BSW from 5% to 97% and in the terminal were tested samplings of bunker with ranges viscosities between (MF 180 to 380). (author)

  17. An innovative discrete multilevel sampler design

    International Nuclear Information System (INIS)

    Marvin, B.K.; De Clercq, P.J.; Taylor, B.B.; Mauro, D.M.

    1995-01-01

    An innovative, small-diameter PVC discrete multilevel sampler (DMLS) was designed for the Electric Power Research Institute (EPRI) to provide low-cost, discrete groundwater samples from shallow aquifers. When combined with appropriately-sized direct push soil sampling technologies, high resolution aquifer characterization can be achieved during initial site assessment or remediation monitoring activities. The sampler is constructed from 1-inch diameter PVC well materials, containing polyethylene tubing threaded through PVC disks. Self-expanding annular and internal bentonite seals were developed which isolate discrete sampling zones. The DMLS design allows customization of sampling and isolation zone lengths to suit site-specific goals. Installation of the DMLS is achieved using a temporary, expendable-tipped casting driven by direct push methods. This technique minimizes mobilization costs, site and soil column disturbances, and allows rapid installation in areas of limited overhead clearance. Successful pilot installations of the DMLS prototype have been made at a former manufactured gas plant (MGP) site and a diesel fuel spill site. Analysis of groundwater samples from these sites, using relative compound distributions and contaminant concentration profiling, confirmed that representative discrete samples were collected. This design provides both economical and versatile groundwater monitoring during all phases of site assessment and remediation

  18. Development of a new passive sampler based on diffusive milligel beads for copper analysis in water

    International Nuclear Information System (INIS)

    Perez, M.; Reynaud, S.; Lespes, G.; Potin-Gautier, M.; Mignard, E.; Chéry, P.; Schaumlöffel, D.; Grassl, B.

    2015-01-01

    A new passive sampler was designed and characterized for the determination of free copper ion (Cu 2+ ) concentration in aqueous solution. Each sampling device was composed of a set of about 30 diffusive milligel (DMG) beads. Milligel beads with incorporated cation exchange resin (Chelex) particles were synthetized using an adapted droplet-based millifluidic process. Beads were assumed to be prolate spheroids, with a diameter of 1.6 mm and an anisotropic factor of 1.4. The milligel was controlled in chemical composition of hydrogel (monomer, cross-linker, initiator and Chelex concentration) and characterized in pore size. Two types of sampling devices were developed containing 7.5% and 15% of Chelex, respectively, and 6 nm pore size. The kinetic curves obtained demonstrated the accumulation of copper in the DMG according to the process described in the literature as absorption (and/or adsorption) and release following the Fick's first law of diffusion. For their use in water monitoring, the typical physico-chemical characteristics of the samplers, i.e. the mass-transfer coefficient (k 0 ) and the sampler-water partition coefficient (K sw ), were determined based on a static exposure design. In order to determine the copper concentration in the samplers after their exposure, a method using DMG bead digestion combined to Inductively Coupled Plasma – Atomic Emission Spectrometry (ICP-AES) analysis was developed and optimized. The DMG devices proved to be capable to absorb free copper ions from an aqueous solution, which could be accurately quantified with a mean recovery of 99% and a repeatability of 7% (mean relative uncertainty). - Highlights: • Controlled geometry of new passive sampler with ellipsoidal shape. • Original manufacturing process based on droplet-based millifluidic device. • Pore size characterization of the sampler. • Mass-transfer and sampler-water partitioning coefficients by static exposure experiments

  19. Development of a new passive sampler based on diffusive milligel beads for copper analysis in water

    Energy Technology Data Exchange (ETDEWEB)

    Perez, M.; Reynaud, S.; Lespes, G.; Potin-Gautier, M. [Université de Pau et des Pays de l’Adour/CNRS UMR IPREM 5254, Hélioparc, 2 av. du Président Angot, 64053 Pau (France); Mignard, E. [CNRS-Solvay-Université Bordeaux, UMR5258, Laboratoire du Futur, 178 Avenue du Dr. A. Schweitzer, 33608 Pessac Cedex (France); Chéry, P. [Bordeaux Science Agro, 1 cours du Général De Gaulle, Gradignan, 33175 (France); Schaumlöffel, D. [Université de Pau et des Pays de l’Adour/CNRS UMR IPREM 5254, Hélioparc, 2 av. du Président Angot, 64053 Pau (France); Grassl, B., E-mail: bruno.grassl@univ-pau.fr [Université de Pau et des Pays de l’Adour/CNRS UMR IPREM 5254, Hélioparc, 2 av. du Président Angot, 64053 Pau (France)

    2015-08-26

    A new passive sampler was designed and characterized for the determination of free copper ion (Cu{sup 2+}) concentration in aqueous solution. Each sampling device was composed of a set of about 30 diffusive milligel (DMG) beads. Milligel beads with incorporated cation exchange resin (Chelex) particles were synthetized using an adapted droplet-based millifluidic process. Beads were assumed to be prolate spheroids, with a diameter of 1.6 mm and an anisotropic factor of 1.4. The milligel was controlled in chemical composition of hydrogel (monomer, cross-linker, initiator and Chelex concentration) and characterized in pore size. Two types of sampling devices were developed containing 7.5% and 15% of Chelex, respectively, and 6 nm pore size. The kinetic curves obtained demonstrated the accumulation of copper in the DMG according to the process described in the literature as absorption (and/or adsorption) and release following the Fick's first law of diffusion. For their use in water monitoring, the typical physico-chemical characteristics of the samplers, i.e. the mass-transfer coefficient (k{sub 0}) and the sampler-water partition coefficient (K{sub sw}), were determined based on a static exposure design. In order to determine the copper concentration in the samplers after their exposure, a method using DMG bead digestion combined to Inductively Coupled Plasma – Atomic Emission Spectrometry (ICP-AES) analysis was developed and optimized. The DMG devices proved to be capable to absorb free copper ions from an aqueous solution, which could be accurately quantified with a mean recovery of 99% and a repeatability of 7% (mean relative uncertainty). - Highlights: • Controlled geometry of new passive sampler with ellipsoidal shape. • Original manufacturing process based on droplet-based millifluidic device. • Pore size characterization of the sampler. • Mass-transfer and sampler-water partitioning coefficients by static exposure experiments.

  20. Bayesian analysis for exponential random graph models using the adaptive exchange sampler

    KAUST Repository

    Jin, Ick Hoon

    2013-01-01

    Exponential random graph models have been widely used in social network analysis. However, these models are extremely difficult to handle from a statistical viewpoint, because of the existence of intractable normalizing constants. In this paper, we consider a fully Bayesian analysis for exponential random graph models using the adaptive exchange sampler, which solves the issue of intractable normalizing constants encountered in Markov chain Monte Carlo (MCMC) simulations. The adaptive exchange sampler can be viewed as a MCMC extension of the exchange algorithm, and it generates auxiliary networks via an importance sampling procedure from an auxiliary Markov chain running in parallel. The convergence of this algorithm is established under mild conditions. The adaptive exchange sampler is illustrated using a few social networks, including the Florentine business network, molecule synthetic network, and dolphins network. The results indicate that the adaptive exchange algorithm can produce more accurate estimates than approximate exchange algorithms, while maintaining the same computational efficiency.

  1. Effects of Hardness on Pintle Rod Performance in the Universal and Retained Gas Samplers

    International Nuclear Information System (INIS)

    BOGER, R.M.

    1999-01-01

    Interaction between hardness of the pintle rods and the retainer rings used in the core samplers is investigated. It is found that ordinary Rockwell C measurements are not sufficient and superficial hardness instruments are recommended to verify hardness since in-production hardness of pintle rods is found to vary widely and probably leads to some premature release of pistons in samplers

  2. Retained Gas Sampler Calibration and Simulant Tests

    Energy Technology Data Exchange (ETDEWEB)

    CRAWFORD, B.A.

    2000-01-05

    This test plan provides a method for calibration of the retained gas sampler (RGS) for ammonia gas analysis. Simulant solutions of ammonium hydroxide at known concentrations will be diluted with isotopically labeled 0.04 M ammonium hydroxide solution. Sea sand solids will also be mixed with ammonium hydroxide solution and diluent to determine the accuracy of the system for ammonia gas analysis.

  3. Retained Gas Sampler Calibration and Simulant Tests

    International Nuclear Information System (INIS)

    CRAWFORD, B.A.

    2000-01-01

    This test plan provides a method for calibration of the retained gas sampler (RGS) for ammonia gas analysis. Simulant solutions of ammonium hydroxide at known concentrations will be diluted with isotopically labeled 0.04 M ammonium hydroxide solution. Sea sand solids will also be mixed with ammonium hydroxide solution and diluent to determine the accuracy of the system for ammonia gas analysis

  4. A Bayesian Sampler for Optimization of Protein Domain Hierarchies

    Science.gov (United States)

    2014-01-01

    Abstract The process of identifying and modeling functionally divergent subgroups for a specific protein domain class and arranging these subgroups hierarchically has, thus far, largely been done via manual curation. How to accomplish this automatically and optimally is an unsolved statistical and algorithmic problem that is addressed here via Markov chain Monte Carlo sampling. Taking as input a (typically very large) multiple-sequence alignment, the sampler creates and optimizes a hierarchy by adding and deleting leaf nodes, by moving nodes and subtrees up and down the hierarchy, by inserting or deleting internal nodes, and by redefining the sequences and conserved patterns associated with each node. All such operations are based on a probability distribution that models the conserved and divergent patterns defining each subgroup. When we view these patterns as sequence determinants of protein function, each node or subtree in such a hierarchy corresponds to a subgroup of sequences with similar biological properties. The sampler can be applied either de novo or to an existing hierarchy. When applied to 60 protein domains from multiple starting points in this way, it converged on similar solutions with nearly identical log-likelihood ratio scores, suggesting that it typically finds the optimal peak in the posterior probability distribution. Similarities and differences between independently generated, nearly optimal hierarchies for a given domain help distinguish robust from statistically uncertain features. Thus, a future application of the sampler is to provide confidence measures for various features of a domain hierarchy. PMID:24494927

  5. Integrated passive flux measurement in groundwater: design and performance of iFLUX samplers

    Science.gov (United States)

    Verreydt, Goedele; Razaei, Meisam; Meire, Patrick; Van Keer, Ilse; Bronders, Jan; Seuntjens, Piet

    2017-04-01

    The monitoring and management of soil and groundwater is a challenge. Current methods for the determination of movement or flux of pollution in groundwater use no direct measurements but only simulations based on concentration measurements and Darcy velocity estimations. This entails large uncertainties which cause remediation failures and higher costs for contaminated site owners. On top of that, the lack of useful data makes it difficult to get approval for a risk-based management approach which completely avoids costly remedial actions. The iFLUX technology is a key development of Dr. Goedele Verreydt at the University of Antwerp and VITO. It is supported by the passive flux measurement technology as invented by Prof. Mike Annable and his team at the University of Florida. The iFLUX technology includes an in situ measurement device for capturing dynamic groundwater quality and quantity, the iFLUX sampler, and an associated interpretation and visualization method. The iFLUX sampler is a modular passive sampler that provides simultaneous in situ point determinations of a time-averaged target compound mass flux and water flux. The sampler is typically installed in a monitoring well where it intercepts the groundwater flow and captures the compounds of interest. The sampler consists of permeable cartridges which are each packed with a specific sorbent matrix. The sorbent matrix of the water flux cartridge is impregnated with known amounts of water soluble resident tracers. These tracers are leached from the matrix at rates proportional to the groundwater flux. The measurements of the contaminants and the remaining resident tracer are used to determine groundwater and target compound fluxes. Exposure times range from 1 week to 6 months, depending on the expected concentration and groundwater flow velocity. The iFLUX sampler technology has been validated and tested at several field projects. Currently, 4 cartridges are tested and available: 1 waterflux cartridge to

  6. Carbon Nanotube Integrative Sampler (CNIS) for passive sampling of nanosilver in the aquatic environment.

    Science.gov (United States)

    Shen, Li; Fischer, Jillian; Martin, Jonathan; Hoque, Md Ehsanul; Telgmann, Lena; Hintelmann, Holger; Metcalfe, Chris D; Yargeau, Viviane

    2016-11-01

    Nanomaterials such as nanosilver (AgNP) can be released into the aquatic environment through production, usage, and disposal. Sensitive and cost-effective methods are needed to monitor AgNPs in the environment. This work is hampered by a lack of sensitive methods to detect nanomaterials in environmental matrixes. The present study focused on the development, calibration and application of a passive sampling technique for detecting AgNPs in aquatic matrixes. A Carbon Nanotube Integrative Sampler (CNIS) was developed using multi-walled carbon nanotubes (CNTs) as the sorbent for accumulating AgNPs and other Ag species from water. Sampling rates were determined in the laboratory for different sampler configurations and in different aquatic matrixes. The sampler was field tested at the Experimental Lakes Area, Canada, in lake water dosed with AgNPs. For a configuration of the CNIS consisting of CNTs bound to carbon fiber (i.e. CNT veil) placed in Chemcatcher® housing, the time weighted average (TWA) concentrations of silver estimated from deployments of the sampler in lake mesocosms dosed with AgNPs were similar to the measured concentrations of "colloidal silver" (i.e. <0.22μm in size) in the water column. For a configuration of CNIS consisting of CNTs in loose powder form placed in a custom made housing that were deployed in a whole lake dosed with AgNPs, the estimated TWA concentrations of "CNIS-labile Ag" were similar to the concentrations of total silver measured in the epilimnion of the lake. However, sampling rates for the CNIS in various matrixes are relatively low (i.e. 1-20mL/day), so deployment periods of several weeks are required to detect AgNPs at environmentally relevant concentrations, which can allow biofilms to develop on the sampler and could affect the sampling rates. With further development, this novel sampler may provide a simple and sensitive method for screening for the presence of AgNPs in surface waters. Copyright © 2016 Elsevier B.V. All

  7. Fast monitoring of indoor bioaerosol concentrations with ATP bioluminescence assay using an electrostatic rod-type sampler.

    Directory of Open Access Journals (Sweden)

    Ji-Woon Park

    Full Text Available A culture-based colony counting method is the most widely used analytical technique for monitoring bioaerosols in both indoor and outdoor environments. However, this method requires several days for colony formation. In this study, our goal was fast monitoring (Sampling: 3 min, Detection: < 1 min of indoor bioaerosol concentrations with ATP bioluminescence assay using a bioaerosol sampler. For this purpose, a novel hand-held electrostatic rod-type sampler (110 mm wide, 115 mm long, and 200 mm tall was developed and used with a commercial luminometer, which employs the Adenosine triphosphate (ATP bioluminescence method. The sampler consisted of a wire-rod type charger and a cylindrical collector, and was operated with an applied voltage of 4.5 kV and a sampling flow rate of 150.7 lpm. Its performance was tested using Staphylococcus epidermidis which was aerosolized with an atomizer. Bioaerosol concentrations were measured using ATP bioluminescence method with our sampler and compared with the culture-based method using Andersen cascade impactor under controlled laboratory conditions. Indoor bioaerosol concentrations were also measured using both methods in various indoor environments. A linear correlation was obtained between both methods in lab-tests and field-tests. Our proposed sampler with ATP bioluminescence method may be effective for fast monitoring of indoor bioaerosol concentrations.

  8. Silicone passive equilibrium samplers as ‘chemometers’ in eels and sediments of a Swedish lake

    DEFF Research Database (Denmark)

    Jahnke, Annika; Mayer, Philipp; McLachlan, Michael S.

    2014-01-01

    Passive equilibrium samplers deployed in two or more media of a system and allowed to come to equilibrium can be viewed as ‘chemometers’ that reflect the difference in chemical activities of contaminants between the media. We applied silicone-based equilibrium samplers to measure relative chemica...... diagenesis and sorption to phytoplankton. The ‘chemometer’ approach has the potential to become a powerful tool to study the thermodynamic controls on persistent organic chemicals in the environment and should be extended to other environmental compartments.......Passive equilibrium samplers deployed in two or more media of a system and allowed to come to equilibrium can be viewed as ‘chemometers’ that reflect the difference in chemical activities of contaminants between the media. We applied silicone-based equilibrium samplers to measure relative chemical...... activities of seven ‘indicator’ polychlorinated biphenyls (PCBs) and hexachlorobenzene in eels and sediments from a Swedish lake. Chemical concentrations in eels and sediments were also measured using exhaustive extraction methods. Lipid-normalized concentrations in eels were higher than organic carbon...

  9. Developments in Emission Measurements Using Lightweight Sensors and Samplers.

    Science.gov (United States)

    Lightweight emission measurement systems making use of miniaturized sensors and samplers have been developed for portable and aerial sampling for an array of pollutants. Shoebox-sized systems called “Kolibri”, weighing 3-5 kg, have been deployed on NASA-flown unmanned...

  10. Constraints on the Within Season and Between Year Variability of the North Residual Cap from MGS-TES

    Science.gov (United States)

    Calvin, W. M.; Titus, T. N.; Mahoney, S. A.

    2003-01-01

    There is a long history of telescopic and spacecraft observations of the polar regions of Mars. The finely laminated ice deposits and surrounding layered terrains are commonly thought to contain a record of past climate conditions and change. Understanding the basic nature of the deposits and their mineral and ice constituents is a continued focus of current and future orbited missions. Unresolved issues in Martian polar science include a) the unusual nature of the CO2 ice deposits ("Swiss Cheese", "slab ice" etc.) b) the relationship of the ice deposits to underlying layered units (which differs from the north to the south), c) understanding the seasonal variations and their connections to the finely laminated units observed in high-resolution images and d) the relationship of dark materials in the wind-swept lanes and reentrant valleys to the surrounding dark dune and surface materials. Our work focuses on understanding these issues in relationship to the north residual ice cap. Recent work using Mars Global Surveyor (MGS) data sets have described evolution of the seasonal CO2 frost deposits. In addition, the north polar residual ice cap exhibits albedo variations between Mars years and within the summer season. The Thermal Emission Spectrometer (TES) data set can augment these observations providing additional constraints such as temperature evolution and spectral properties associated with ice and rocky materials. Exploration of these properties is the subject of our current study.

  11. Comparison of particulate matter exposure estimates in young children from personal sampling equipment and a robotic sampler.

    Science.gov (United States)

    Sagona, Jessica A; Shalat, Stuart L; Wang, Zuocheng; Ramagopal, Maya; Black, Kathleen; Hernandez, Marta; Mainelis, Gediminas

    2017-05-01

    Accurate characterization of particulate matter (PM) exposure in young children is difficult, because personal samplers are often too heavy, bulky or impractical to be used. The Pretoddler Inhalable Particulate Environmental Robotic (PIPER) sampler was developed to help address this problem. In this study, we measured inhalable PM exposures in 2-year-olds via a lightweight personal sampler worn in a small backpack and evaluated the use of a robotic sampler with an identical sampling train for estimating PM exposure in this age group. PM mass concentrations measured by the personal sampler ranged from 100 to almost 1,200 μg/m 3 , with a median value of 331 μg/m 3 . PM concentrations measured by PIPER were considerably lower, ranging from 14 to 513 μg/m 3 with a median value of 56 μg/m 3 . Floor cleaning habits and activity patterns of the 2-year-olds varied widely by home; vigorous play and recent floor cleaning were most associated with higher personal exposure. Our findings highlight the need for additional characterization of children's activity patterns and their effect on personal exposures.

  12. Assessment of personal exposure to airborne nanomaterials: Evaluation of a novel sampler

    International Nuclear Information System (INIS)

    Faure, Bertrand; Dozol, Hélène; Brouard, Christophe; Guiot, Arnaud; Clavaguera, Simon

    2017-01-01

    A novel sampler, the NANOBADGE, has been developed to assess personal exposure to nano-objects, agglomerates and aggregates (NOAA) at the workplace. The NANOBADGE collects particles on filters subsequently analyzed by X-Ray Fluorescence spectroscopy (XRF), which provides a mass-based quantification with chemical selectivity. The NANOBADGE was benchmarked against a scanning mobility particle sizer (SMPS) and a DiSCmini by carrying out simultaneous measurements on test aerosols of ZnO or TiO 2 for particle sizes between 20 and 400 nm for which the DiSCmini has its highest accuracy. The effective density and shape of the NOAA present in the test aerosols were determined experimentally to compare number-based data obtained with the SMPS and the DiSCmini with mass-based data obtained with the NANOBADGE. The agreement between the SMPS and the NANOBADGE sampler was within ± 25 % on all test aerosols. The converted DiSCmini data matched the SMPS and sampler data for polydisperse aerosols in the specified size range as long as the DiSCmini assumptions meet the aerosol characteristics (i.e. lognormal size distribution with a given geometric standard deviation σg = 1.9). The detection limits of the NANOBADGE sampler were in the order of tens of nanograms per filter, which is low enough to reliably detect exposure levels below the recommended exposure limit (REL) of the National Institute for Occupational Safety and Health (NIOSH) and the Institut National de Recherche et de Sécurité (INRS) for ultrafine ZnO and TiO 2 even for short-term exposure situations. (paper)

  13. Effect of housing geometry on the performance of ChemcatcherTM passive sampler for the monitoring of hydrophobic organic pollutants in water

    International Nuclear Information System (INIS)

    Lobpreis, Tomas; Vrana, Branislav; Dominiak, Ewa; Dercova, Katarina; Mills, Graham A.; Greenwood, Richard

    2008-01-01

    Passive sampling of pollutants in water has been gaining acceptance for environmental monitoring. Previously, an integrative passive sampler (the Chemcatcher TM ) was developed and calibrated for the measurement of time weighted average concentrations of hydrophobic pollutants in water. Effects of physicochemical properties and environmental variables (water temperature and turbulence) on kinetic and thermodynamic parameters characterising the exchange of analytes between the sampler and water have been published. In this study, the effect of modification in sampler housing geometry on these calibration parameters was studied. The results obtained for polycyclic aromatic hydrocarbons show that reducing the depth of the cavity in the sampler body geometry increased the exchange kinetics by approximately twofold, whilst having no effect on the correlation between the uptake and offload kinetics of analytes. The use of performance reference compounds thus avoids the need for extensive re-calibration when the sampler body geometry is modified. - The effect of passive sampler geometry on accumulation kinetics of organic pollutants from water was evaluated

  14. Photodegradation of polyaromatic hydrocarbons in passive air samplers: Field testing different deployment chambers

    International Nuclear Information System (INIS)

    Bartkow, Michael E.; Kennedy, Karen E.; Huckins, James N.; Holling, Neil; Komarova, Tatiana; Mueller, Jochen F.

    2006-01-01

    Semi-permeable membrane devices (SPMDs) were loaded with deuterated anthracene and pyrene as performance reference compounds (PRCs) and deployed at a test site in four different chambers (open and closed box chamber, bowl chamber and cage chamber) for 29 days. The losses of PRCs and the uptake of polyaromatic hydrocarbons (PAHs) from the ambient air were quantified. UV-B levels measured in each deployment chamber indicated that SPMDs would be exposed to the most UV-B in the cage chamber and open box chamber. Significantly less PAHs were quantified in SPMDs deployed in the cage chamber and open box chamber compared to samplers from the other two chambers, suggesting that photodegradation of PAHs had occurred. The loss of PRCs confirmed these results but also showed that photodegradation was occurring in the closed box chamber. The bowl chamber appears to provide the best protection from the influence of direct photodegradation. - Photodegradation/loss of PAHs occurs from passive air samplers (SPMDs) deployed in various sampler chambers

  15. Waveform Sampler CAMAC Module

    International Nuclear Information System (INIS)

    Freytag, D.R.; Haller, G.M.; Kang, H.; Wang, J.

    1985-09-01

    A Waveform Sampler Module (WSM) for the measurement of signal shapes coming from the multi-hit drift chambers of the SLAC SLC detector is described. The module uses a high speed, high resolution analog storage device (AMU) developed in collaboration between SLAC and Stanford University. The AMU devices together with high speed TTL clocking circuitry are packaged in a hybrid which is also suitable for mounting on the detector. The module is in CAMAC format and provides eight signal channels, each recording signal amplitude versus time in 512 cells at a sampling rate of up to 360 MHz. Data are digitized by a 12-bit ADC with a 1 μs conversion time and stored in an on-board memory accessible through CAMAC

  16. Design and laboratory testing of a new flow-through directional passive air sampler for ambient particulate matter.

    Science.gov (United States)

    Lin, Chun; Solera Garcia, Maria Angeles; Timmis, Roger; Jones, Kevin C

    2011-03-01

    A new type of directional passive air sampler (DPAS) is described for collecting particulate matter (PM) in ambient air. The prototype sampler has a non-rotating circular sampling tray that is divided into covered angular channels, whose ends are open to winds from sectors covering the surrounding 360°. Wind-blown PM from different directions enters relevant wind-facing channels, and is retained there in collecting pools containing various sampling media. Information on source direction and type can be obtained by examining the distribution of PM between channels. Wind tunnel tests show that external wind velocities are at least halved over an extended area of the collecting pools, encouraging PM to settle from the air stream. Internal and external wind velocities are well-correlated over an external velocity range of 2.0-10.0 m s⁻¹, which suggests it may be possible to relate collected amounts of PM simply to ambient concentrations and wind velocities. Measurements of internal wind velocities in different channels show that velocities decrease from the upwind channel round to the downwind channel, so that the sampler effectively resolves wind directions. Computational fluid dynamics (CFD) analyses were performed on a computer-generated model of the sampler for a range of external wind velocities; the results of these analyses were consistent with those from the wind tunnel. Further wind tunnel tests were undertaken using different artificial particulates in order to assess the collection performance of the sampler in practice. These tests confirmed that the sampler can resolve the directions of sources, by collecting particulates preferentially in source-facing channels.

  17. Direct imaging and new technologies to search for substellar companions around MGs cool dwarfs

    Directory of Open Access Journals (Sweden)

    Burningham B.

    2011-07-01

    Full Text Available We describe here our project based in a search for sub-stellar companions (brown dwarfs and exo-planets around young ultra-cool dwarfs (UCDs and characterise their properties. We will use current and future technology (high contrast imaging, high-precision Doppler determinations from the ground and space (VLT, ELT and JWST, to find companions to young objects. Members of young moving groups (MGs have clear advantages in this field. We compiled a catalogue of young UCD objects and studied their membership to five known young moving groups: Local Association (Pleiades moving group, 20–150 Myr, Ursa Mayor group (Sirius supercluster, 300 Myr, Hyades supercluster (600 Myr, IC 2391 supercluster (35 Myr and Castor moving group (200 Myr. To assess them as members we used different kinematic and spectroscopic criteria.

  18. Characteristics and Sampling Efficiencies of Two Impactor Bioaerosol Samplers: MAS-100(Registered) (Microbial Air Monitoring System) and Single-Stage Andersen Viable Microbial Samplers

    National Research Council Canada - National Science Library

    Hottell, K

    2004-01-01

    .... A petri dish with agar is used as the impaction surface for these samplers. The MAS-l00 is a single-stage impactor that aspirates air through a 400-hole perforated entry plate onto an agar plate at an airflow rate of 100 L/min...

  19. Development of floor smear sampler (floor radioactive contamination measuring instrument) for nuclear facilities

    International Nuclear Information System (INIS)

    Miyagawa, Minoru; Ito, Haruo; Nozawa, Katsuro; Shinohara, Yotaro; Hashimoto, Hiroshi.

    1980-01-01

    The control of the floor contamination with radioactive substances in nuclear facilities is strictly carried out by smear method, in which the contaminants on floor surfaces are wiped off with filter papers or cloths, and the contamination density on the floor surfaces is measured through their intensity of radioactivity. This wiping work is laborious since it is carried out in leaning-over posture when many samples must be taken in wide floor area. Therefore, to achieve labor saving in this work, an automatic sampler was developed. In the floor smear sampler developed, samples are taken on long band type wiping cloths only by handle operation, and the sample numbers are printed. When many samples are taken in wide floor area, this is especially effective, and the labor saving by 1/3 to 1/2 can be achieved. At present, this sampler is put in practical use in Hamaoka Nuclear Power Station. At the time of trial manufacture, the method of wiping, the mechanisms of wiping, cloth feeding and running, the contact pressure and the number of times of wiping affecting wiping efficiency and the required torque of a motor were examined. The developed sampler is that of constant contact pressure, vibration wiping type, and the rate of sampling is 10 sec per one sample. 100 samples can be taken on one roll of wiping cloth. The results of performance test are reported. (Kako, I.)

  20. Accuracy criteria recommended for the certification of gravimetric coal-mine-dust samplers

    International Nuclear Information System (INIS)

    Bowman, J.D.; Bartley, D.L.; Breuer, G.M.; Doemeny, L.J.; Murdock, D.J.

    1984-07-01

    Procedures for testing bias and precision of gravimetric coal-mine-dust sampling units are reviewed. Performance criteria for NIOSH certification of personal coal-mine dust samplers are considered. The NIOSH criterion is an accuracy of 25% at the 95% confidence interval. Size distributions of coal-mine-dust are discussed. Methods for determining size distributions are described. Sampling and sizing methods are considered. Cyclone parameter estimation is discussed. Bias computations for general sampling units are noted. Recommended procedures for evaluating bias and precision of gravimetric coal mine dust personal samplers are given. The authors conclude that when cyclones are operated at lower rates, the NIOSH accuracy criteria can be met

  1. 7 CFR 61.33 - Equipment of sampler; contents of certificate.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Equipment of sampler; contents of certificate. 61.33 Section 61.33 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE (CONTINUED) REGULATIONS...

  2. The effect of size-selective samplers (cyclones) on XRD response

    CSIR Research Space (South Africa)

    Pretorius, CJ

    2011-07-01

    Full Text Available The study evaluated five size-selective samplers used in the South African mining industry to determine how their performance affects the X-ray powder diffraction (XRD) response when respirable dust samples are analysed for quartz using direct...

  3. Development of a silicone-membrane passive sampler for monitoring cylindrospermopsin and microcystin LR-YR-RR in natural waters

    Science.gov (United States)

    Nyoni, Hlengilizwe; Mamba, Bhekie B.; Msagati, Titus A. M.

    2017-08-01

    Silicone membrane tubes were functionalised by filling them with synthesised γ-Fe2O3 nanoparticles and used as a passive sampling device for monitoring microcystins and cylindrospermopsin in aquatic environments. This novel device was calibrated for the measurement of microcystin and cylindrospermopsin concentrations in water. The effect of temperature and hydrodynamics on the sampler performance was studied in a flow-through system under controlled conditions. The chemical uptake of microcystins (MCs) and cylindrospermopsin (CYN) into the passive sampler remained linear and integrative throughout the exposure period. The rate of accumulation of most of the MC compounds tested was dependent on temperature and flow velocity. The use of 13C labelled polychlorinated biphenyls as performance reference compounds (PRCs) in silicone membrane/γ-Fe2O3 nanoparticle passive sampler, Chemcatcher and polar organic chemical integrative sampler (POCIS) was evaluated. The majority of PRCs improved the semi quantitative nature of water concentration estimated by the three samplers. The corrected sampling rate values of model biotoxin compounds were used to estimate the time-weighted average concentrations in natural cyanobacterial water blooms of the Hartbeespoort dam. The corrected sampling rates RScorr values varied from 0.1140 to 0.5628 Ld-1 between samplers with silicone membrane having the least RScorr values compared to the Chemcatcher and POCIS. The three passive sampling devises provided a more relevant picture of the biotoxin concentration in the Hartbeespoort dam. The results suggested that the three sampling devices are suitable for use in monitoring microcystins and cylindrospermopsin concentrations in aquatic environments.

  4. A critical assessment of passive air samplers for per- and polyfluoroalkyl substances

    Science.gov (United States)

    Karásková, Pavlína; Codling, Garry; Melymuk, Lisa; Klánová, Jana

    2018-07-01

    Since their inclusion in the Stockholm Convention, there has been a need for global monitoring of perfluorooctane sulfonate (PFOS), its salts and perfluorooctanesulfonyl fluoride (PFOSF), along with other non-listed highly fluorinated compounds. Passive air samplers (PAS) are ideal for geographic coverage of atmospheric monitoring. The most common type of PAS, using polyurethane foam (PUF) as a sorbent, was primarily developed for non-polar semivolatile organic compounds (SVOCs) and are not well-validated for polar substances such as the per- and polyfluoroalkyl substances (PFASs), however, they have been used for some PFASs, particularly PFOS. To evaluate their applicability, PAS were deployed for measurement of PFASs in outdoor and indoor air. Outdoors, two types of PAS, one consisting of PUF and one of XAD-2 resin, were deployed in an 18-week calibration study in parallel with a low-volume active air sampler (LV-AAS) in a suburban area. Indoors, PUF-PAS were similarly deployed over 12 weeks to evaluate their applicability for indoor monitoring. Samples were analysed for perfluoroalkyl carboxylic acids (PFCAs), perfluoroalkyl sulfonates (PFSAs), perfluorooctane sulfonamides (FOSAs), and perfluorooctane sulfonamidoethanols (FOSEs). In outdoor air, 17 out of the 21 PFAS were detected in more than 50% of samples, with a median ∑17PFASs of 18.0 pg m-3 while 20 compounds were detected in indoor air with a median concentration ∑20PFASs of 76.6 pg m-3 using AAS samplers. PFOS was the most common PFAS in the outdoor air while PFBA was most common indoors. Variability between PAS and AAS was observed and comparing gas phase and particle phase separately or in combination did not account for the variation observed. PUF-PAS may still have a valuable use in PFAS monitoring but more work is needed to identify the applicability of passive samplers for ionic PFAS.

  5. Sorbent Film-Coated Passive Samplers for Explosives Vapour Detection Part A: Materials Optimisation and Integration with Analytical Technologies.

    Science.gov (United States)

    McEneff, Gillian L; Murphy, Bronagh; Webb, Tony; Wood, Dan; Irlam, Rachel; Mills, Jim; Green, David; Barron, Leon P

    2018-04-11

    A new thin-film passive sampler is presented as a low resource dependent and discrete continuous monitoring solution for explosives-related vapours. Using 15 mid-high vapour pressure explosives-related compounds as probes, combinations of four thermally stable substrates and six film-based sorbents were evaluated. Meta-aramid and phenylene oxide-based materials showed the best recoveries from small voids (~70%). Analysis was performed using liquid chromatography-high resolution accurate mass spectrometry which also enabled tentative identification of new targets from the acquired data. Preliminary uptake kinetics experiments revealed plateau concentrations on the device were reached between 3-5 days. Compounds used in improvised explosive devices, such as triacetone triperoxide, were detected within 1 hour and were stably retained by the sampler for up to 7 days. Sampler performance was consistent for 22 months after manufacture. Lastly, its direct integration with currently in-service explosives screening equipment including ion mobility spectrometry and thermal desorption mass spectrometry is presented. Following exposure to several open environments and targeted interferences, sampler performance was subsequently assessed and potential interferences identified. High-security building and area monitoring for concealed explosives using such cost-effective and discrete passive samplers can add extra assurance to search routines while minimising any additional burden on personnel or everyday site operation.

  6. Airborne radioiodine species sampler and it's application for measuring removal efficiencies of large charcoal adsorbers for ventilation exhaust air

    International Nuclear Information System (INIS)

    Emel, D.; Hetzer, D.; Pelletier, C.A.; Barefoot, E.D.; Cline, J.E.

    1976-01-01

    A program, sponsored by the Electric Power Research Institute, is underway to determine the chemical species of radioiodine coming from LWR power plants and their persistence in the nearby environment. In support of this program, an airborne radioiodine sampler, developed and used by the AEC was modified and tested. This sampler consists of five components. The components are: (1) a particulate filter, (2) CdI 2 on a matrix of chromosorb-P to retain I 2 , (3) 4-Iodophenol on a matrix of activated alumina to retain HOI, (4) silver exchanged molecular sieve-13X to retain organic iodides, and (5) impregnated charcoal to serve as a control. The AEC sampler has not been proof-tested for periods over 48 hours or for flow rates above 0.10 l/s. For maximum sensitivity, a sampler is required to be used for periods of one to two weeks and at a flow rate giving a bed residence time of 0.1 sec. The AEC sampler was scaled up in size to attain an air sampling rate of 0.9 l/s. Each media for this sampler (except the particulate filter) was tested in the laboratory for retention of the iodine species; I 2 , Organic, and HOI. The tests were conducted at typical conditions observed at the main iodine release points at nuclear power plants. Confirmatory tests were run at operating nuclear power plants. The test results showed that under normal plant conditions the sampler could be operated at flow rates up to 0.80 l/s and differentiate the iodine species I 2 , HOI, and CH 3 I. The retention efficiencies of each media for its specie of radioiodine were found to be: I 2 on CdI 2 - 87 +- 5%, HOI on IPH 94 +- 4%, and CH 3 I on Ag 13-X or KI charcoal 99 +- 1%

  7. Composite sampling of a Bacillus anthracis surrogate with cellulose sponge surface samplers from a nonporous surface.

    Directory of Open Access Journals (Sweden)

    Jenia A M Tufts

    Full Text Available A series of experiments was conducted to explore the utility of composite-based collection of surface samples for the detection of a Bacillus anthracis surrogate using cellulose sponge samplers on a nonporous stainless steel surface. Two composite-based collection approaches were evaluated over a surface area of 3716 cm2 (four separate 929 cm2 areas, larger than the 645 cm2 prescribed by the standard Centers for Disease Control (CDC and Prevention cellulose sponge sampling protocol for use on nonporous surfaces. The CDC method was also compared to a modified protocol where only one surface of the sponge sampler was used for each of the four areas composited. Differences in collection efficiency compared to positive controls and the potential for contaminant transfer for each protocol were assessed. The impact of the loss of wetting buffer from the sponge sampler onto additional surface areas sampled was evaluated. Statistical tests of the results using ANOVA indicate that the collection of composite samples using the modified sampling protocol is comparable to the collection of composite samples using the standard CDC protocol (p  =  0.261. Most of the surface-bound spores are collected on the first sampling pass, suggesting that multiple passes with the sponge sampler over the same surface may be unnecessary. The effect of moisture loss from the sponge sampler on collection efficiency was not significant (p  =  0.720 for both methods. Contaminant transfer occurs with both sampling protocols, but the magnitude of transfer is significantly greater when using the standard protocol than when the modified protocol is used (p<0.001. The results of this study suggest that composite surface sampling, by either method presented here, could successfully be used to increase the surface area sampled per sponge sampler, resulting in reduced sampling times in the field and decreased laboratory processing cost and turn-around times.

  8. A survey of perfluoroalkyl sulfonamides in indoor and outdoor air using passive air samplers

    Energy Technology Data Exchange (ETDEWEB)

    Shoeib, M.; Harner, T. [Meteorological Service of Canada, Environment Canada (Canada); Wilford, B.; Jones, K. [Lancaster Univ. (United Kingdom). Environmental Science; Zhu, J. [Chemistry Research Division, Health Canada, Tunney' s Pasture, Ottawa (Canada)

    2004-09-15

    Perfluorooctane sulfonate (PFOS) has recently emerged as a priority environmental pollutant due to its widespread detection in biological samples from remote regions including the Arctic and the Mid-North Pacific Ocean. Because PFOS is fairly involatile, it is hypothesized that its occurrence in remote regions is the result of atmospheric transport of more volatile precursor compounds such as the perfluoroalkyl sulfonamides (PFASs). PFASs are used in variety of consumer products for water and oil resistance including surface treatments for fabric, upholstery, carpet, paper and leather. In a recent pilot study employing high volume air samples, indoor air concentrations of PFASs were approximately 100 times greater than outdoor levels. This is of significance because people typically spend about 90% of their time indoors 5 and this exposure may serve as an important uptake pathway. Indoor air also serves as a source of PFASs to the outside where PFASs are ultimately transported and distributed throughout the environment. The current study is intended to be a more comprehensive survey of indoor and outdoor air allowing more confident conclusions to be made. Passive air samplers comprised of polyurethane foam (PUF) disks were used. These are quiet, non-intrusive samplers that operate without the aid of a pump or electricity. Air movement delivers chemical to the sampler which has a high retention capacity for persistent organic pollutants (POPs). PUF disks samplers have been previously used successfully to monitor different classes of hydrophobic persistent organic pollutants POPs.

  9. 7 CFR 801.5 - Tolerance for diverter-type mechanical samplers.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 7 2010-01-01 2010-01-01 false Tolerance for diverter-type mechanical samplers. 801.5 Section 801.5 Agriculture Regulations of the Department of Agriculture (Continued) GRAIN INSPECTION... OFFICIAL PERFORMANCE REQUIREMENTS FOR GRAIN INSPECTION EQUIPMENT § 801.5 Tolerance for diverter-type...

  10. Evaluation of intake efficiencies and associated sediment-concentration errors in US D-77 bag-type and US D-96-type depth-integrating suspended-sediment samplers

    Science.gov (United States)

    Sabol, Thomas A.; Topping, David J.

    2013-01-01

    Accurate measurements of suspended-sediment concentration require suspended-sediment samplers to operate isokinetically, within an intake-efficiency range of 1.0 ± 0.10, where intake efficiency is defined as the ratio of the velocity of the water through the sampler intake to the local ambient stream velocity. Local ambient stream velocity is defined as the velocity of the water in the river at the location of the nozzle, unaffected by the presence of the sampler. Results from Federal Interagency Sedimentation Project (FISP) laboratory experiments published in the early 1940s show that when the intake efficiency is less than 1.0, suspended-sediment samplers tend to oversample sediment relative to water, leading to potentially large positive biases in suspended-sediment concentration that are positively correlated with grain size. Conversely, these experiments show that, when the intake efficiency is greater than 1.0, suspended‑sediment samplers tend to undersample sediment relative to water, leading to smaller negative biases in suspended-sediment concentration that become slightly more negative as grain size increases. The majority of FISP sampler development and testing since the early 1990s has been conducted under highly uniform flow conditions via flume and slack-water tow tests, with relatively little work conducted under the greater levels of turbulence that exist in actual rivers. Additionally, all of this recent work has been focused on the hydraulic characteristics and intake efficiencies of these samplers, with no field investigations conducted on the accuracy of the suspended-sediment data collected with these samplers. When depth-integrating suspended-sediment samplers are deployed under the more nonuniform and turbulent conditions that exist in rivers, multiple factors may contribute to departures from isokinetic sampling, thus introducing errors into the suspended-sediment data collected by these samplers that may not be predictable on the basis

  11. CAM and stack air sampler design guide

    International Nuclear Information System (INIS)

    Phillips, T.D.

    1994-01-01

    About 128 air samplers and CAMs presently in service to detect and document potential radioactive release from 'H' and 'F' area tank farm ventilation stacks are scheduled for replacement and/or upgrade by Projects S-5764, S-2081, S-3603, and S-4516. The seven CAMs scheduled to be upgraded by Project S-4516 during 1995 are expected to provide valuable experience for the three remaining projects. The attached document provides design guidance for the standardized High Level Waste air sampling system

  12. Task QA plan for Modified Prototypic Hydragard trademark Sampler Overflow System Demonstration at TNX

    International Nuclear Information System (INIS)

    Snyder, T.K.

    1993-01-01

    The primary objective of this task is to evaluate the proposed design modifications to the sample system, including the adequacy of the recommended eductor and the quality of samples obtained from the modified system. Presently, the sample streams are circulated from the originating tank, through a Hydragard trademark sampler system, and back to the originating tank. The overflow from the Hydragard trademark sampler flows to the Recycle Collection Tank (RCT). This report outlines the planned quality assurance controls for the design modification task, including organization and personnel, surveillances, and records package

  13. Evaluation of Intake Efficiencies and Associated Sediment-Concentration Errors in US D-77 Bag-Type and US D-96-Type Depth-Integrating Suspended-Sediment Samplers

    Science.gov (United States)

    Sabol, T. A.; Topping, D. J.; Griffiths, R. E.

    2011-12-01

    Accurate measurements of suspended-sediment concentration require suspended-sediment samplers to operate isokinetically with an intake-efficiency of 1.0 ± 0.10. Results from 1940s Federal Interagency Sedimentation Project (FISP) laboratory experiments show that when the intake efficiency does not equal 1.0, suspended-sediment samplers either under- or oversample sediment relative to water, leading to biases in suspended-sediment concentration. The majority of recent FISP sampler development and testing has been conducted under uniform flow conditions using flume and slack-water tow tests, with little testing in actual turbulent rivers. Recent work has focused on the hydraulic characteristics and intake efficiencies of these samplers, without field investigations of the accuracy of the suspended-sediment data collected with these samplers. When depth-integrating suspended-sediment samplers are deployed under the non-uniform and turbulent conditions that exist in rivers, multiple factors may contribute to departures from isokinetic sampling. This introduces errors into the suspended-sediment data that may not be predictable on the basis of flume and tow tests alone. This study (1) evaluates the intake efficiencies of the older US D-77 bag-type and newer, FISP-approved US D-96 samplers at multiple river cross sections under a range of flow conditions; (2) examines if water temperature and sampling duration explain measured differences in intake efficiency between samplers and between laboratory and field tests; (3) models and predicts the directions and magnitudes of errors in measured suspended-sand concentration; and (4) determines if the relative differences in suspended-sediment concentration in a variety of size classes are consistent with the differences expected on the basis of the 1940s FISP-laboratory experiments. Results indicate that under river conditions, the intake efficiency of the US D-96 sampler is superior to that of the US D-77 bag-type sampler and

  14. Evaluation of personal inhalable aerosol samplers with different filters for use during anthrax responses.

    Science.gov (United States)

    Grinshpun, Sergey A; Weber, Angela M; Yermakov, Michael; Indugula, Reshmi; Elmashae, Yousef; Reponen, Tiina; Rose, Laura

    2017-08-01

    Risk of inhalation exposure to viable Bacillus anthracis (B. anthracis) spores has primarily been assessed using short-term, stationary sampling methods which may not accurately characterize the concentration of inhalable-sized spores reaching a person's breathing zone. While a variety of aerosol sampling methods have been utilized during previous anthrax responses, no consensus has yet been established for personal air sampling. The goal of this study was to determine the best sampler-filter combination(s) for the collection and extraction of B. anthracis spores. The study was designed to (1) evaluate the performance of four filter types (one mixed cellulose ester, MCE (pore size = 3 µm), two polytetrafluoroethylene, PTFE (1 and 3 µm), and one polycarbonate, PC (3 µm)); and (2) evaluate the best performing filters in two commercially available inhalable aerosol samplers (IOM and Button). Bacillus thuringiensis kurstaki [Bt(k)], a simulant for B. anthracis, served as the aerosol challenge. The filters were assessed based on criteria such as ability to maintain low pressure drop over an extended sampling period, filter integrity under various environmental conditions, spore collection and extraction efficiencies, ease of loading and unloading the filters into the samplers, cost, and availability. Three of the four tested collection filters-except MCE-were found suitable for efficient collection and recovery of Bt(k) spores sampled from dry and humid as well as dusty and clean air environments for up to 8 hr. The PC (3 µm) filter was identified as the best performing filter in this study. The PTFE (3 µm) demonstrated a comparable performance, but it is more expensive. Slightly higher concentrations were measured with the IOM inhalable sampler which is the preferred sampler's performance criterion when detecting a highly pathogenic agent with no established "safe" inhalation exposure level. Additional studies are needed to address the effects of

  15. The Winfrith portable self-contained air samplers, type W.A.S. 1

    International Nuclear Information System (INIS)

    Cavell, I.W.

    1961-11-01

    This memorandum describes a self-contained air sampler for collecting samples of airborne particulates on a standard 6 centimetre filter paper. Its construction, use and performance are discussed. (author)

  16. A new application of passive samplers as indicators of in-situ biodegradation processes.

    Science.gov (United States)

    Belles, Angel; Alary, Claire; Criquet, Justine; Billon, Gabriel

    2016-12-01

    In this paper, a method for evaluating the in-situ degradation of nitro polycyclic aromatic hydrocarbons (nitro-PAH) in sediments is presented. The methodology is adapted from the passive sampler technique, which commonly uses the dissipation rate of labeled compounds loaded in passive sampler devices to sense the environmental conditions of exposure. In the present study, polymeric passive samplers (made of polyethylene strips) loaded with a set of labeled polycyclic aromatic hydrocarbons (PAH) and nitro-PAH were immersed in sediments (in field and laboratory conditions) to track the degradation processes. This approach is theoretically based on the fact that a degradation process induces a steeper concentration gradient of the labeled compounds in the surrounding sediment, thereby increasing their compound dissipation rates compared with their dissipation in abiotic conditions. Postulating that the degradation magnitude is the same for the labeled compounds loaded in polyethylene strips and for their native homologs that are potentially present in the sediment, the field degradation of 3 nitro-PAH (2-nitro-fluorene, 1-nitro-pyrene, 6-nitro-chrysene) was semi-quantitatively analyzed using the developed method. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. Validation of ammonia diffusive and active samplers in a controlled atmosphere test facility using traceable Primary Standard Gas Mixtures

    Science.gov (United States)

    Martin, Nicholas A.; Ferracci, Valerio; Cassidy, Nathan; Hook, Josh; Battersby, Ross M.; Tang, Yuk S.; Stevens, Amy C. M.; Jones, Matthew R.; Braban, Christine F.; Gates, Linda; Hangartner, Markus; Stoll, Jean-Marc; Sacco, Paolo; Pagani, Diego; Hoffnagle, John A.

    2017-04-01

    Intensive animal farming, the increased use of fertilizers, and certain industrial processes are believed to be responsible for the observed increases in the amount fraction of ammonia (NH3) found in Europe. NH3 contributes to eutrophication and acidification of land and freshwater, potentially leading to a loss of biodiversity and undesirable changes to the ecosystem. It also contributes to the formation of secondary particulate matter (PM) formation, which is associated with poor air quality and adverse health outcomes. Measurements of ambient ammonia are principally carried out with low-cost diffusive samplers or by active sampling with denuders, with each method delivering time-integrated values over the monitoring period. However, such techniques have not yet been extensively validated. The goal of this work was to provide improvements in the metrological traceability through the determination of NH3 diffusive sampling rates. Five different designs of commercial diffusive samplers (FSM Radiello radial sampler, Gradko diffusion tube, Gradko DIFRAM-400, Passam ammonia sampler, and CEH ALPHA sampler) were employed, together with a pumped denuder sampler (CEH DELTA denuder) for comparison. All devices were simultaneously exposed for either 28 days or 14 days (dependent on sampler type) in a controlled atmosphere test facility (CATFAC) containing traceable amount fractions of humidified ammonia using new stable ammonia Primary Standard Gas Mixtures developed by gravimetry at NPL, under a wide range of conditions that are relevant to ambient monitoring. Online continuous monitoring of the ammonia test atmospheres was carried out by extractive sampling, employing a calibrated cavity ring-down spectrometer, which had been modified to account for cross interference by water vapour. Each manufacturer extracted the captured ammonia on the exposed samplers in the form of ammonium (NH4+) using their own accredited traceable wet chemical techniques, and then reported data

  18. Visual Chronicles from the Balkans and Central Europe: Samplers Remembered

    Directory of Open Access Journals (Sweden)

    Maria-Alina Asavei

    2016-03-01

    Full Text Available This paper examines the relationship between craft and popular culture by focusing on a peculiar type of textile sampler (needlework that used to be omnipresent in the last century both in rural and urban houses across Central and South-Eastern Europe. Although these hand-crafted items are no longer part of today’s ‘compulsory’ household, they are still regarded as nostalgic, familiar or emotional forms of materiality and tangibility which perform a cultural politics of identity. These vernacular textiles predate the digital age and the free market and yet co-evolve and interact with digital networks and technologies. This paper brings into focus ‘amateur’ and regional forms of home grown cultural expression and the ways in which these forms of folk creativity and materiality are recast in contemporary urban popular culture and arts. Thus, the main aim of this study is to explore the contemporary re-enactments of these vernacular samplers.

  19. Development of an automatic smear sampler and evaluation of surface contamination

    International Nuclear Information System (INIS)

    Seo, B. K.; Lee, B. J.; Lee, K. W.; Park, J. H.

    2004-01-01

    The surface contamination level of a radiation-controlled area is measured periodically according to atomic energy law and connection regulations. The measurement of surface contamination by an indirect method is subject to various kinds of error depending on the sampling person and consumes much time and effort in the sampling of large nuclear facilities. In this research, an automatic smear sampler is developed to solve these problems. The developed equipment is composed of a rotating sampling part, a sample transferring part, a power supply part a control part, and vacuum part. It improved the efficiency of estimation of the surface contamination level achieved periodically in a radiation-controlled area. Using an automatic smear sampler developed in this research, it is confirmed that radioactive contaminated materials are uniformly transferred to smear paper more than any sampling method by an operator. (authors)

  20. Air sampler performance at Ford's farm range

    International Nuclear Information System (INIS)

    Glissmeyer, J.A.; Johnston, J.W.

    1984-07-01

    An air-sampling system for a large-caliber depleted uranium (DU) penetrator firing range was tested. The objectives of the test were: to determine the bias between the monitoring readings and DU concentrations; and to determine if the target bay real-time monitor (RTM) tracks the decaying dust concentration. The test procedure was to operate total and respirable airborne particle samplers adjacent to the target bay monitors. A series of air samples was also taken after the test firings adjacent to the target bay RTM. Exhaust particle samples were analyzed for gross alpha, gross beta and uranium content. The target bay RTM correlated well (0.977) with the sequential samples. Average concentration from the RTM did not correlate with either the long-term total or respirable sampler DU concentrations. The monitor used to confirm a low dust concentration when the door is open correlated well (0.810) with the RTM; the other bay monitor did not. In the ventilation discharge, the long-term average monitor readings did not correlate with DU concentrations, probably due to levels near lower detection limits. Smearable surface-contamination samples showed highest contamination on the equipment, gravel floor and exhaust intake. The location air-intake contamination increased over the first 3 rounds. Contamination was reduced by a low-pressure water spray washdown to about the same concentration as often the second round, then remained at about twice the level. 2 references, 18 figures, 16 tables. (MF)

  1. Assessment of benthic macroinvertebrates at Nile tilapia production using artificial substrate samplers

    Directory of Open Access Journals (Sweden)

    M. S. G. Moura e Silva

    Full Text Available Abstract Biomonitoring is a cheap and effective tool for evaluation of water quality, and infer on the balance of aquatic ecosystems. The benthic macroinvertebrates are bioindicators sensitive to environmental changes, and can assist in detecting and preventing impacts such as organic enrichment and imbalance in the food chain. We compared the structure of benthic communities on artificial substrate samplers located in places near and far from net cages for production of Nile tilapia (Oreochromis niloticus. Samplers were manufactured with nylon net, using substrates such as crushed stone, gravel, loofah and cattail leaves. Samples were collected after 30 days of colonization, rinsed and then the specimens were identified and quantified. The following metrics were calculated: richness of Operational Taxonomic Units, Margalef richness, abundance of individuals, Shannon index and evenness index. The macrobenthic community structure was strongly modified according to the proximity of the net cages. Metrics showed significant differences (p < 0.05 between near and distant sites, for both periods (dry and rainy seasons. The position of the samplers significantly affected the structure of macroinvertebrate community, as near sites showed higher values for the community metrics, such as richness and diversity. Near sites presented a larger number of individuals, observed both in the dry and rainy seasons, with a predominance of Chironomidae (Diptera in the dry season and Tubificidae (Oligochaeta in the rainy season.

  2. MARS GLOBAL SURVEYOR RAW DATA SET - CRUISE V1.0

    Data.gov (United States)

    National Aeronautics and Space Administration — The Mars Global Surveyor (MGS) Radio Science (RS) Raw Data Archive (RDA) is a time-ordered collection of raw and partially processed data collected during the MGS...

  3. The performance of passive flow monitors and phosphate accumulating passive samplers when exposed to pulses in external water flow rate and/or external phosphate concentrations

    International Nuclear Information System (INIS)

    O'Brien, Dominique; Hawker, Darryl; Shaw, Melanie; Mueller, Jochen F.

    2011-01-01

    Passive samplers are typically calibrated under constant flow and concentration conditions. This study assessed whether concentration and/or flow pulses could be integrated using a phosphate passive sampler (P-sampler). Assessment involved three 21-day experiments featuring a pulse in flow rate, a pulse of filterable reactive phosphate (FRP) concentration and a simultaneous concentration and flow pulse. FRP concentrations were also determined by parallel grab sampling and the P-sampler calibrated with passive flow monitors (PFMs) and direct measurement of flow rates. The mass lost from the PFM over the deployment periods predicted water velocity to within 5.1, 0.48 and 7.1% when exposed to a flow rate pulse (7.5-50 cm s -1 ), concentration pulse (5-100 μg P L -1 ), or both simultaneously. For the P-sampler, good agreement was observed between the grab and passive measurements of FRP concentration when exposed to a pulse in flow (6% overestimation) or concentration (2% underestimation). - Highlights: → We assess the performance of the passive flow monitor and a phosphate passive sampler when exposed to changing environmental conditions. → The PFM responded quickly and accurately to a pulse in flow rate but showed little response to an external FRP pulse. → The ability of the sampler to provide an integrated measure of the average phosphate concentrations has been demonstrated. → The results presented demonstrate under which conditions the greatest accuracy is achieved when employing passive samplers. - The performance of an integrative phosphate passive sampler has been assessed when exposed to pulses in flow rate and concentration, both individually and simultaneously.

  4. Retained gas sampler interim safety assessment

    Energy Technology Data Exchange (ETDEWEB)

    Pasamehmetoglu, K.O.; Miller, W.O.; Unal, C.; Fujita, R.K.

    1995-01-13

    This safety assessment addresses the proposed action to install, operate, and remove a Retained Gas Sampler (RGS) in Tank 101-SY at Hanford. Purpose of the RGS is to help characterize the gas species retained in the tank waste; the information will be used to refine models that predict the gas-producing behavior of the waste tank. The RGS will take samples of the tank from top to bottom; these samples will be analyzed for gas constituents. The proposed action is required as part of an evaluation of mitigation concepts for eliminating episodic gas releases that result in high hydrogen concentrations in the tank dome space.

  5. Retained gas sampler interim safety assessment

    International Nuclear Information System (INIS)

    Pasamehmetoglu, K.O.; Miller, W.O.; Unal, C.; Fujita, R.K.

    1995-01-01

    This safety assessment addresses the proposed action to install, operate, and remove a Retained Gas Sampler (RGS) in Tank 101-SY at Hanford. Purpose of the RGS is to help characterize the gas species retained in the tank waste; the information will be used to refine models that predict the gas-producing behavior of the waste tank. The RGS will take samples of the tank from top to bottom; these samples will be analyzed for gas constituents. The proposed action is required as part of an evaluation of mitigation concepts for eliminating episodic gas releases that result in high hydrogen concentrations in the tank dome space

  6. Evaluation and application of a passive air sampler for polycylic aromatic hydrocarbons (PAHs).

    Science.gov (United States)

    Esen, Fatma; Evci, Yildiz M; Tasdemir, Yucel

    2017-08-24

    Sampling of 15 PAHs by the use of both passive air sampler developed (D-PAS) in our research group and PAS (C-PAS) having widespread use in the literature was conducted to compare the performances of the samplers. Sampling was carried out for 1-year period (February 2013-February 2014), in different sampling periods by employing D-PAS and C-PAS. D-PAS and C-PAS were run in parallel for 10, 20, 30, 40 and 60 days. Sampling rates were calculated for both PASs by the use of concentration values obtained from a high-volume air sampler (HVAS). It was determined that calculated sampling values are different from each other by definition of design of C-PAS and D-PAS and difference in environment as velocity of wind and temperature are having different effects upon sampling rates. Collected σ 15 PAHs amounts of 10-day periods in spring, summer, autumn and winter were obtained as 576 ± 333, 209 ± 29, 2402 ± 910 and 664 ± 246 ng for D-PAS and 1070 ± 522, 318 ± 292, 6062 ± 1501 and 6089 ± 4018 ng for C-PAS, respectively. In addition, according to seasons, when collected PAHs in two different samplers were considered, similar results were obtained for the summer time in which no combustion takes place with the aim of domestic heating, while there were differences determined for the seasons with combustion in need of domestic heating. Gas-phase σ 15 PAHs' concentrations were reported depending on seasons in the spring, summer, autumn and winter sequences as 46 ± 32, 9 ± 3, 367 ± 207 and 127 ± 93 ng m -3 for HVAS, respectively.

  7. User's guide for polyethylene-based passive diffusion bag samplers to obtain volatile organic compound concentrations in wells. Part 2, Field tests

    Science.gov (United States)

    Vroblesky, Don A.

    2001-01-01

    Diffusion samplers installed in observation wells were found to be capable of yielding representative water samples for chlorinated volatile organic compounds. The samplers consisted of polyethylene bags containing deionized water and relied on diffusion of chlorinated volatile organic compounds through the polyethylene membrane. The known ability of polyethylene to transmit other volatile compounds, such as benzene and toluene, indicates that the samplers can be used for a variety of volatile organic compounds. In wells at the study area, the volatile organic compound concentrations in water samples obtained using the samplers without prior purging were similar to concentrations in water samples obtained from the respective wells using traditional purging and sampling approaches. The low cost associated with this approach makes it a viable option for monitoring large observation-well networks for volatile organic compounds.

  8. A new sampler for simulating aerosol deposition in the respiratory tract

    International Nuclear Information System (INIS)

    Li Dehong; Zhuo Weihai; Yi Yanling; Chen Bo; Liu Haikuan

    2008-01-01

    For estimation of the deposition fractions of radon progeny in different regions of the respiratory tract, a new sampler consisting of three different configurations of sampling heads was developed. The deposition fractions of aerosols on the wire screens inside the sampling heads were calculated with the fan model of filtration theory. The deposition fractions of aerosols in different regions of the respiratory tract were calculated with the lung dose evaluation program (LUDEP) developed by National Radiological Protection Board (NRPB) as references. In general indoor and mine environments, the deviation between the deposition fractions of attached aerosol on the wire screens designed in this study and its reference values in the respiratory tract is less than 5%. It is possible to accurately estimate the deposition fractions of radon progeny in different regions of the respiratory tract through mimic measurements of radon progeny collected with the new sampler. (authors)

  9. A Compact Diffusion Sampler for Environmental Applications Requiring HTO or HTO + HT Determinations

    International Nuclear Information System (INIS)

    Otlet, R.L.; Walker, A.J.; Mather, I.D.

    2005-01-01

    Passive diffusion samplers have now been in use in the UK for the measurement of tritium at environmental levels in the form of HTO and HTO + HT for more than ten years. At the outset their main purpose was to identify the direction of a possible inadvertent release of tritium into the environment. More recently, however, there has been growing interest in their use as stand-alone devices for tritium determination at environmental levels. This has necessitated a more rigorous design to reduce the 'draughts effect' in exposed locations and has also required modifications to enable the measurement of HTO + HT. The paper describes the recent design improvements and the results of validation tests carried out against dynamic, discriminating (dry-bed) samplers

  10. The determination of volatile chlorinated hydrocarbons in air. Sampling rate and efficiency of diffuse samplers

    Energy Technology Data Exchange (ETDEWEB)

    Giese, U.; Stenner, H.; Kettrup, A.

    1989-05-01

    When applicating diffusive sampling-systems to workplace air-monitoring it is necessary to know the behaviour of the diffusive-rate and the efficiency in dependence of concentration, exposition time and the type of pollutant. Especially concerning mixtures of pollutants there are negative influences by competition and mutual displacement possible. Diffusive-rate and discovery for CH/sub 2/Cl/sub 2/ and CHCl/sub 3/ were investigated using two different types of diffuse samplers. For this it was necessary to develop suitable defices for standard gas generation and for the exposition of diffusive-samplers to a standard gas mixture. (orig.).

  11. Iowa Developed Energy Activity Sampler (IDEAS), Grades 7-12: Social Studies.

    Science.gov (United States)

    Simonis, Doris G.

    Described is the Social Studies component of the Iowa Developed Energy Activity Sampler (IDEAS), a multidisciplinary energy education program designed for infusion into the curriculum of grades seven through twelve. Aspects of the energy situation addressed in these lessons include resource finiteness, exponential growth, standard of living,…

  12. Performance of passive samplers for monitoring estuarine water column concentrations: 2. Emerging contaminants.

    Science.gov (United States)

    Perron, Monique M; Burgess, Robert M; Suuberg, Eric M; Cantwell, Mark G; Pennell, Kelly G

    2013-10-01

    Measuring dissolved concentrations of emerging contaminants, such as polybrominated diphenyl ethers (PBDEs) and triclosan, can be challenging due to their physicochemical properties resulting in low aqueous solubilities and association with particles. Passive sampling methods have been applied to assess dissolved concentrations in water and sediments primarily for legacy contaminants. Although the technology is applicable to some emerging contaminants, the use of passive samplers with emerging contaminants is limited. In the present study, the performance of 3 common passive samplers was evaluated for sampling PBDEs and triclosan. Passive sampling polymers included low-density polyethylene (PE) and polyoxymethylene (POM) sheets, and polydimethylsiloxane (PDMS)-coated solid-phase microextraction (SPME) fibers. Dissolved concentrations were calculated using measured sampler concentrations and laboratory-derived partition coefficients. Dissolved tri-, tetra-, and pentabrominated PBDE congeners were detected at several of the study sites at very low pg/L concentrations using PE and POM. Calculated dissolved water concentrations of triclosan ranged from 1.7 ng/L to 18 ng/L for POM and 8.8 ng/L to 13 ng/L for PE using performance reference compound equilibrium adjustments. Concentrations in SPME were not reported due to lack of detectable chemical in the PDMS polymer deployed. Although both PE and POM were found to effectively accumulate emerging contaminants from the water column, further research is needed to determine their utility as passive sampling devices for emerging contaminants. © 2013 SETAC.

  13. Development of a passive sampler based on a polymer inclusion membrane for total ammonia monitoring in freshwaters.

    Science.gov (United States)

    Almeida, M Inês G S; Silva, Adélia M L; Coleman, Rhys A; Pettigrove, Vincent J; Cattrall, Robert W; Kolev, Spas D

    2016-05-01

    A passive sampler for determining the time-weighted average total ammonia (i.e. molecular ammonia and the ammonium cation) concentration (C TWA) in freshwaters, which incorporated a polymer inclusion membrane (PIM) as a semi-permeable barrier separating the aqueous source solution from the receiving solution (i.e. 0.8 mol L(-1) HCl), was developed for the first time. The PIM was composed of dinonylnaphthalene sulfonic acid (DNNS) as a carrier, poly (vinyl chloride) (PVC) as a base polymer and 1-tetradecanol as a modifier. Its optimal composition was found to be 35 wt% commercial DNNS, 55 wt% PVC and 10 wt% 1-tetradecanol. The effect of environmental variables such as the water matrix, pH and temperature were also studied using synthetic freshwaters. The passive sampler was calibrated under laboratory conditions using synthetic freshwaters and exhibited a linear response within the concentration range 0.59-2.8 mg L(-1) NH4(+) (0.46-2.1 mg N L(-1)) at 20 °C. The performance of the sampler was further investigated under field conditions over 7 days. A strong correlation between spot sampling and passive sampling was achieved, thus providing a proof-of-concept for the passive sampler for reliably measuring the C(TWA) of total ammonia in freshwaters, which can be used as an indicator in tracking sources of faecal contamination in stormwater drains.

  14. Unified Frequency-Domain Analysis of Switched-Series-RC Passive Mixers and Samplers

    NARCIS (Netherlands)

    Soer, M.C.M.; Klumperink, Eric A.M.; de Boer, Pieter-Tjerk; van Vliet, Frank Edward; Nauta, Bram

    2010-01-01

    Abstract—A wide variety of voltage mixers and samplers are implemented with similar circuits employing switches, resistors, and capacitors. Restrictions on duty cycle, bandwidth, or output frequency are commonly used to obtain an analytical expression for the response of these circuits. This paper

  15. Assessing the transport of PAH in the surficial sediment layer by passive sampler approach.

    Science.gov (United States)

    Belles, Angel; Alary, Claire; Criquet, Justine; Ivanovsky, Anastasia; Billon, Gabriel

    2017-02-01

    A new method based on passive samplers has been developed to assess the diffusive flux of fluorene, fluoranthene and pyrene in the sediment bed and across the sediment-water interface. The dissolved compound concentration gradient in the sediment in the vertical direction was measured at the outlet of a storm water pond by using polyethylene strips as passive samplers. Simultaneously, the dissipation of a set of tracer compounds preloaded in the passive samplers was measured to estimate the effective diffusion coefficients of the pollutants in the sediment. Both measurements were used to evaluate the diffusive flux of the compounds according to Fick's first law. The diffusive fluxes of the 3 studied compounds have been estimated with a centimetre-scale resolution in the upper 44cm of the sediment. According to the higher compound diffusion coefficient and the steeper concentration gradient in the surficial sediment layer, the results show that the net flux of compounds near the sediment interface (1cm depth) is on average 500 times higher than in the deep sediment, with average fluxes at 1cm depth on the order of 5, 0.1 and 0.1ng/m 2 /y for fluorene, fluoranthene and pyrene, respectively. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Evaluation of polyurethane foam passive air sampler (PUF) as a tool for occupational PAH measurements.

    Science.gov (United States)

    Strandberg, Bo; Julander, Anneli; Sjöström, Mattias; Lewné, Marie; Koca Akdeva, Hatice; Bigert, Carolina

    2018-01-01

    Routine monitoring of workplace exposure to polycyclic aromatic hydrocarbons (PAHs) is performed mainly via active sampling. However, active samplers have several drawbacks and, in some cases, may even be unusable. Polyurethane foam (PUF) as personal passive air samplers constitute good alternatives for PAH monitoring in occupational air (8 h). However, PUFs must be further tested to reliably yield detectable levels of PAHs in short exposure times (1-3 h) and under extreme occupational conditions. Therefore, we compared the personal exposure monitoring performance of a passive PUF sampler with that of an active air sampler and determined the corresponding uptake rates (Rs). These rates were then used to estimate the occupational exposure of firefighters and police forensic specialists to 32 PAHs. The work environments studied were heavily contaminated by PAHs with (for example) benzo(a)pyrene ranging from 0.2 to 56 ng m -3 , as measured via active sampling. We show that, even after short exposure times, PUF can reliably accumulate both gaseous and particle-bound PAHs. The Rs-values are almost independent of variables such as the concentration and the wind speed. Therefore, by using the Rs-values (2.0-20 m 3 day -1 ), the air concentrations can be estimated within a factor of two for gaseous PAHs and a factor of 10 for particulate PAHs. With very short sampling times (1 h), our method can serve as a (i) simple and user-friendly semi-quantitative screening tool for estimating and tracking point sources of PAH in micro-environments and (ii) complement to the traditional active pumping methods. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  17. Performance of a hydrostatic sampler for collecting samples at the water-sediment interface in lakes

    Directory of Open Access Journals (Sweden)

    Fernando PEDROZO

    2008-02-01

    Full Text Available The water-sediment interface plays a significant role in the determination of the trophic degree of a waterbody. Numerous redox reactions take place there, resulting in the release of contaminants from the sediments to the water column. The aim of the present work was to develop an equipment for collecting samples from the water-sediment interface. Such equipment was to have a simple design, low construction cost, no depth limitations, and high levels of personal safety and to be reliable in the collection of samples. The performance of the hydrostatic sampler thus developed was tested against samples collected either remotely with a corer or directly with syringes by autonomous divers. The hydrostatic sampler permits access to depths where the costs of the traditional diving methodology are expensive, and where working conditions are dangerous for the diver. The hydrostatic sampler provides an additional means of collecting samples from the water-sediment interface, which together with pore-water samples, facilitates the investigation and understanding of chemical mechanisms in lakes, for instance, those that control the P release from sediment to the water column.

  18. Pesticide impact on aquatic invertebrates identified with Chemcatcher® passive samplers and the SPEAR(pesticides) index.

    Science.gov (United States)

    Münze, Ronald; Orlinskiy, Polina; Gunold, Roman; Paschke, Albrecht; Kaske, Oliver; Beketov, Mikhail A; Hundt, Matthias; Bauer, Coretta; Schüürmann, Gerrit; Möder, Monika; Liess, Matthias

    2015-12-15

    Pesticides negatively affect biodiversity and ecosystem function in aquatic environments. In the present study, we investigated the effects of pesticides on stream macroinvertebrates at 19 sites in a rural area dominated by forest cover and arable land in Central Germany. Pesticide exposure was quantified with Chemcatcher® passive samplers equipped with a diffusion-limiting membrane. Ecological effects on macroinvertebrate communities and on the ecosystem function detritus breakdown were identified using the indicator system SPEARpesticides and the leaf litter degradation rates, respectively. A decrease in the abundance of pesticide-vulnerable taxa and a reduction in leaf litter decomposition rates were observed at sites contaminated with the banned insecticide Carbofuran (Toxic Units≥-2.8), confirming the effect thresholds from previous studies. The results show that Chemcatcher® passive samplers with a diffusion-limiting membrane reliably detect ecologically relevant pesticide pollution, and we suggest Chemcatcher® passive samplers and SPEARpesticides as a promising combination to assess pesticide exposure and effects in rivers and streams. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Design of data sampler in intelligent physical start-up system for nuclear reactor

    International Nuclear Information System (INIS)

    Wang Yinli; Ling Qiu

    2007-01-01

    It introduces the design of data sampler in intelligent physical start-up system for nuclear reactor. The hardware frame taking STμPSD3234A as the core and the firmware design based on USB interface are discussed. (authors)

  20. Optimal Management Of Renewable-Based Mgs An Intelligent Approach Through The Evolutionary Algorithm

    Directory of Open Access Journals (Sweden)

    Mehdi Nafar

    2015-08-01

    Full Text Available Abstract- This article proposes a probabilistic frame built on Scenario fabrication to considerate the uncertainties in the finest action managing of Micro Grids MGs. The MG contains different recoverable energy resources such as Wind Turbine WT Micro Turbine MT Photovoltaic PV Fuel Cell FC and one battery as the storing device. The advised frame is based on scenario generation and Roulette wheel mechanism to produce different circumstances for handling the uncertainties of altered factors. It habits typical spreading role as a probability scattering function of random factors. The uncertainties which are measured in this paper are grid bid alterations cargo request calculating error and PV and WT yield power productions. It is well-intentioned to asset that solving the MG difficult for 24 hours of a day by considering diverse uncertainties and different constraints needs one powerful optimization method that can converge fast when it doesnt fall in local optimal topic. Simultaneously single Group Search Optimization GSO system is presented to vision the total search space globally. The GSO algorithm is instigated from group active of beasts. Also the GSO procedure one change is similarly planned for this algorithm. The planned context and way is applied o one test grid-connected MG as a typical grid.

  1. Passive sampling of selected endocrine disrupting compounds using polar organic chemical integrative samplers

    International Nuclear Information System (INIS)

    Arditsoglou, Anastasia; Voutsa, Dimitra

    2008-01-01

    Two types of polar organic chemical integrative samplers (pharmaceutical POCIS and pesticide POCIS) were examined for their sampling efficiency of selected endocrine disrupting compounds (EDCs). Laboratory-based calibration of POCISs was conducted by exposing them at high and low concentrations of 14 EDCs (4-alkyl-phenols, their ethoxylate oligomers, bisphenol A, selected estrogens and synthetic steroids) for different time periods. The kinetic studies showed an integrative uptake up to 28 days. The sampling rates for the individual compounds were obtained. The use of POCISs could result in an integrative approach to the quality status of the aquatic systems especially in the case of high variation of water concentrations of EDCs. The sampling efficiency of POCISs under various field conditions was assessed after their deployment in different aquatic environments. - Calibration and field performance of polar organic integrative samplers for monitoring EDCs in aquatic environments

  2. Experimental typing of the entry efficiency in calm air of an annular slot sampler; Determination experimentale de l'efficacite de captage en air calme d'un echantillonneur a fente annulaire

    Energy Technology Data Exchange (ETDEWEB)

    Roger, F.; Fabries, J.F.; Gorner, P.; Wrobel, R. [Institut National de Recherche et de Securite, INRS, Lab. de Metrologie de la Pollution par les Aerosols, 54 - Vandoeuvre-Les-Nancy (France); Renoux, A. [Paris-12 Univ., Lab. de Physique des Aerosols et de Transfert des Contaminations, 94 - Creteil (France)

    2000-07-01

    Aerosol sampling is a complex physical process that depends on many parameters like particle size, wind speed, aspiration velocity and sampler geometry. Inertia has a predominant influence on particle motion in moving air for particle size above 1 {mu}m. In calm air where air movement is mainly induced by the aspiration orifice of the sampler, gravitational settling affects more deeply particle motion and hence sampler performance. The entry efficiency of a sampler with an annular aspiration slot was recently measured for several conditions of aspiration flow rate, wind speed (1 and 3 m s{sup -1}) and geometric parameters of the sampler as a function of particle aerodynamic diameter. Some complementary work was carried out to add new experimental data corresponding to the same sampler in calm air. The results were obtained for 9 configurations, combining several values of disc diameter, aspiration slot width, and aspiration velocity. A semi-empirical model was developed from the data that enables the calculation of particle entry efficiency of the annular sampler in calm air. In addition, a numerical study was carried out to calculate the particle trajectories approaching the annular aspiration slot of the sampler. The results show that particle rebounds on the sampler walls have a significant effect on the entry efficiency of the sampler in calm air. (authors)

  3. Evaluation of a depth proportional intake device for automatic pumping samplers

    Science.gov (United States)

    Rand E. Eads; Robert B. Thomas

    1983-01-01

    Abstract - A depth proportional intake boom for portable pumping samplers was used to collect suspended sediment samples in two coastal streams for three winters. The boom pivots on the stream bed while a float on the downstream end allows debris to depress the boom and pass without becoming trapped. This equipment modifies point sampling by maintaining the intake...

  4. PERFORMANCE OF A NEW DIFFUSIVE SAMPLER FOR HG0 DETERMINATION IN THE TROPOSPHERE

    Science.gov (United States)

    Mercury behaves uniquely in the atmosphere due to its volatility and long lifetime. The existing methods for measuring atmospheric mercury are either expensive or labour intensive. The present paper presents a new measurement technique, the diffusive sampler, that is portable, in...

  5. Combining polar organic chemical integrative samplers (POCIS) with toxicity testing to evaluate pesticide mixture effects on natural phototrophic biofilms

    International Nuclear Information System (INIS)

    Pesce, Stephane; Morin, Soizic; Lissalde, Sophie; Montuelle, Bernard; Mazzella, Nicolas

    2011-01-01

    Polar organic chemical integrative samplers (POCIS) are valuable tools in passive sampling methods for monitoring polar organic pesticides in freshwaters. Pesticides extracted from the environment using such methods can be used to toxicity tests. This study evaluated the acute effects of POCIS extracts on natural phototrophic biofilm communities. Our results demonstrate an effect of POCIS pesticide mixtures on chlorophyll a fluorescence, photosynthetic efficiency and community structure. Nevertheless, the range of biofilm responses differs according to origin of the biofilms tested, revealing spatial variations in the sensitivity of natural communities in the studied stream. Combining passive sampler extracts with community-level toxicity tests offers promising perspectives for ecological risk assessment. - Research highlights: → Polar organic chemical integrative samplers (POCIS) were used for monitoring polar organic pesticides in a contaminated river. → The acute effects of POCIS extracts were tested on natural phototrophic biofilm communities. → POCIS pesticide mixtures affected chlorophyll a fluorescence, photosynthetic efficiency and community structure. → Biofilm responses differed according to origin of the biofilms tested, revealing variations in the sensitivity of natural communities. → Combining passive sampler extracts with community-level toxicity tests offers promising perspectives for ecological risk assessment. - Pesticide mixtures extracted from POCIS can affect chl a fluorescence, photosynthetic efficiency and community structure of natural biofilms.

  6. Investigation of the tritium release from Building 324 in which the stack tritium sampler was off, April 14 through 17, 1998

    International Nuclear Information System (INIS)

    Brown, D.H.

    1998-01-01

    On April 14, 1998, a Pacific Northwest National Laboratory (PNNL) researcher performing work in the Building 324 facility approached facility management and asked if facility management could turn off the tritium sampler in the main exhaust stack. The researcher was demonstrating the feasibility of treating components from dismantled nuclear weapons in a device called a plasma arc furnace and was concerned that the sampler would compromise classified information. B and W Hanford Company (BWHC) operated the facility, and PNNL conducted research as a tenant in the facility. The treatment of 200 components in the furnace would result in the release of up to about 20 curies of tritium through the facility stack. The exact quantity of tritium was calculated from the manufacturing data for the weapons components and was known to be less than 20 curies. The Notice of Construction (NOC) approved by the Washington State Department of Health (WDOH) had been modified to allow releasing 20 curies of tritium through the stack in support of this research. However, there were irregularities in the way the NOC modification was processed. The researcher was concerned that data performed on the sampler could be used to back-calculate the tritium content of the components, revealing classified information about the design of nuclear weapons. He had discussed this with the PNNZ security organization, and they had told him that data from the sampler would be classified. He was also concerned that if he could not proceed with operation of the plasma arc furnace, the furnace would be damaged. The researcher told BWHC management that the last time the furnace was shut down and restarted it had cost $0.5 million and caused a six month delay in the project's schedule. He had already begun heating up the furnace before recognizing the security problem and was concerned that stopping the heatup could damage the furnace. The NOC that allowed the research did not have an explicit requirement to

  7. Development of a new passive sampler based on diffusive milligel beads for copper analysis in water.

    Science.gov (United States)

    Perez, M; Reynaud, S; Lespes, G; Potin-Gautier, M; Mignard, E; Chéry, P; Schaumlöffel, D; Grassl, B

    2015-08-26

    A new passive sampler was designed and characterized for the determination of free copper ion (Cu(2+)) concentration in aqueous solution. Each sampling device was composed of a set of about 30 diffusive milligel (DMG) beads. Milligel beads with incorporated cation exchange resin (Chelex) particles were synthetized using an adapted droplet-based millifluidic process. Beads were assumed to be prolate spheroids, with a diameter of 1.6 mm and an anisotropic factor of 1.4. The milligel was controlled in chemical composition of hydrogel (monomer, cross-linker, initiator and Chelex concentration) and characterized in pore size. Two types of sampling devices were developed containing 7.5% and 15% of Chelex, respectively, and 6 nm pore size. The kinetic curves obtained demonstrated the accumulation of copper in the DMG according to the process described in the literature as absorption (and/or adsorption) and release following the Fick's first law of diffusion. For their use in water monitoring, the typical physico-chemical characteristics of the samplers, i.e. the mass-transfer coefficient (k0) and the sampler-water partition coefficient (Ksw), were determined based on a static exposure design. In order to determine the copper concentration in the samplers after their exposure, a method using DMG bead digestion combined to Inductively Coupled Plasma - Atomic Emission Spectrometry (ICP-AES) analysis was developed and optimized. The DMG devices proved to be capable to absorb free copper ions from an aqueous solution, which could be accurately quantified with a mean recovery of 99% and a repeatability of 7% (mean relative uncertainty). Copyright © 2015 Elsevier B.V. All rights reserved.

  8. BCE selector valves and flow proportional sampler

    International Nuclear Information System (INIS)

    Rippy, G.L.

    1994-01-01

    This Acceptance Test Procedure (ATP) has been prepared to demonstrate that the Electrical/Instrumentation systems for the B-Plant Process Condensate Treatment Facility (BCE) function as required by project criteria. Tests will be run to: Verify the operation of the solenoid valve and associated limit switches installed for the BCE portion of W-007H; Operate the solenoid valve and verify the proper operation of the associated limit switches based on the position of the solenoid valve;and, Demonstrate the integrity of the Sample Failure Alarm Relay XFA-211BA-BCE-1, and Power Failure ALarm Relay JFA-211BA-BCE-1 located inside the Flow Proportional Sampler in Building 211 BA

  9. Calibration sources for the G-M counter used with the BNL air sampler

    International Nuclear Information System (INIS)

    Huchton, R.L.; Bird, S.K.; Tkachyk, J.W.; Motes, B.G.

    1983-12-01

    Three calibration sources were designed, developed, and fabricated for a CDV-700 ratemeter equipped with a specially-shielded 6306 G-M detector. The CDV-700/6306 has been proposed for use with the BNL Air Sampler designed for radioiodine monitoring upon a nuclear reactor accident. Specifically, three sources were constructed in a geometry identical to the BNL Air Sampler radioiodine adsorption canister, which is a silver-silica-gel filled 2.75-inch diameter right circular cylinder with a 1.0 inch daimater annulus for insertion of the 6306 G-M detector. As fabricated, each source consisted of an outer stainless steel housing, an inner 133 Ba impregnated polyester liner, 4 weight percent silver steel lid. Respectively, the levels of 133 Ba, an 131 I simulant, were varied in the three sources to yield nominal CDV-700/6306 instrument responses of 200 cpm, 2000 cpm, and 20,000 cpm

  10. The ''Gent'' stacked filter unit (SFU) sampler for the collection of atmospheric aerosols in two size fractions: Description and instructions for installation and use

    International Nuclear Information System (INIS)

    Maenhaut, W.; Francois, F.; Cafmeyer, J.

    1994-01-01

    This report contains a description and general instructions for the installation and use of the ''Gent'' Stacked Filter Unit (SFU) PM10 sampler. The sampler operates at a flow rate of 16 litres per min. It collects particulates which have an equivalent aerodynamic diameter (EAD) of less than 10 μm in separate ''coarse'' (2-10 μm EAD) and ''fine'' ( 10 μm EAD particles is accomplished by a PM10 pre-impaction stage upstream of the stacked filter cassette. The air is drawn through the sampler by means of a diaphragm vacuum pump, which is enclosed in a special housing together with a needle valve, vacuum gauge, flow meter, volume meter, time switch (for interrupted sampling) and hour meter. A list of manufacturers of the various components of the sampler is also given. (author). 4 figs, 1 tab

  11. The influence of geometry and draught shields on the performance of passive samplers

    NARCIS (Netherlands)

    Hofschreuder, P.; Meulen, van der W.; Heeres, P.; Slanina, J.

    1999-01-01

    Passive samplers provide an excellent opportunity to perform indicative measurements or establish a dense network of measuring sites. A drawback compared with conventional active measuring methods is the larger spread of results. This variation can, to a large extent, be attributed to the influence

  12. Silicone Wristband Passive Samplers Yield Highly Individualized Pesticide Residue Exposure Profiles.

    Science.gov (United States)

    Aerts, Raf; Joly, Laure; Szternfeld, Philippe; Tsilikas, Khariklia; De Cremer, Koen; Castelain, Philippe; Aerts, Jean-Marie; Van Orshoven, Jos; Somers, Ben; Hendrickx, Marijke; Andjelkovic, Mirjana; Van Nieuwenhuyse, An

    2018-01-02

    Monitoring human exposure to pesticides and pesticide residues (PRs) remains crucial for informing public health policies, despite strict regulation of plant protection product and biocide use. We used 72 low-cost silicone wristbands as noninvasive passive samplers to assess cumulative 5-day exposure of 30 individuals to polar PRs. Ethyl acetate extraction and LC-MS/MS analysis were used for the identification of PRs. Thirty-one PRs were detected of which 15 PRs (48%) were detected only in worn wristbands, not in environmental controls. The PRs included 16 fungicides (52%), 8 insecticides (26%), 2 herbicides (6%), 3 pesticide derivatives (10%), 1 insect repellent (3%), and 1 pesticide synergist (3%). Five detected pesticides were not approved for plant protection use in the EU. Smoking and dietary habits that favor vegetable consumption were associated with higher numbers and higher cumulative concentrations of PRs in wristbands. Wristbands featured unique PR combinations. Our results suggest both environment and diet contributed to PR exposure in our study group. Silicone wristbands could serve as sensitive passive samplers to screen population-wide cumulative dietary and environmental exposure to authorized, unauthorized and banned pesticides.

  13. Multipurpose sampler device for liquid metal

    International Nuclear Information System (INIS)

    Nelson, P.A.; Kolba, V.M.; Holmes, J.T.

    1975-01-01

    A device for collecting samples or examining a flow of liquid metal is provided for use with such as a liquid-metal-cooled nuclear reactor. The sampler device includes a casing surrounded by an external heater for establishing an upper isothermal zone and a lower zone for heating the entering liquid metal. One of various inserts is suspended into the isothermal zone where it is surrounded by a shroud tube for directing liquid-metal flow from the heating zone into the top of the insert. Discharge flow from the insert gravitates through a helically wound tube in heat exchange contact with entering liquid-metal flow within the heating zone. The inserts comprise an overflow cup with upper and lower freeze seals, a filter for removing particulate matter, and a fixture for maintaining various sample materials in equilibrium with liquid-metal flow. (U.S.)

  14. Responses of low pressure Andersen sampler for collecting substrates

    Energy Technology Data Exchange (ETDEWEB)

    Yamasaki, K. [Research Reactor Institute, Kyoto University, Osaka (Japan); Yamada, Y.; Miyamoto, K.; Shimo, M. [Division of Radiotoxicology and Protection, National Institute of Radiological Sciences, Chiba (Japan)

    2000-05-01

    Some types of low pressure cascade impactors (Andersen, Berner, Davies, and MOUDI etc) have been used to measure the activity size distribution of radon progeny in the environment. In spite of their careful uses, their nonideal responses are not adequately known. Some important factors such as the wall loss, electrostatic attraction, and the surface nature of collecting substrates may affect the reliability of the impactor data. Size selective characteristics of a low pressure Andersen sampler for various collecting substrates were examined in a radon exposure chamber using several kinds of liquid (DOS) or solid (carnauba wax) carrier aerosols labelled with radon progeny. These carrier aerosols were produced by commercial condensation aerosol generator. Tested collecting substrates were, (1) uncoated clean stainless steel plate, (2) silicone oil or grease coated stainless steel plate, (3) polyethylene sheet covered stainless steel plate, (4) membrane filter, (5) glass fiber filter, and (6) quartz fiber filter. In the case of collecting liquid or sticky carrier aerosols, the effect of particle bounce was small and nearly any substrates might used on the impaction plate. On the other hand, in the case of solid carrier aerosols, an adhesive layer such as grease or oil might have to be applied to the substrate. It was concluded that a low pressure cascade impactor such as Andersen sampler might need an appropriate calibration procedure including the interstage characteristics for determining the accurate activity size distribution. (author)

  15. Comparison of POCIS passive samplers vs. composite water sampling: A case study.

    Science.gov (United States)

    Criquet, Justine; Dumoulin, David; Howsam, Michael; Mondamert, Leslie; Goossens, Jean-François; Prygiel, Jean; Billon, Gabriel

    2017-12-31

    The relevance of Polar Organic Chemical Integrative Samplers (POCIS) was evaluated for the assessment of concentrations of 46 pesticides and 19 pharmaceuticals in a small, peri-urban river with multi-origin inputs. Throughout the period of POCIS deployment, 24h-average water samples were collected automatically, and showed the rapid temporal evolution of concentrations of several micropollutants, as well as permitting the calculation of average concentrations in the water phase for comparison with those estimated from POCIS passive samplers. In the daily water samples, cyproconazol, epoxyconazol and imidacloprid showed high temporal variations with concentrations ranging from under the limit of detection up to several hundreds of ngL -1 . Erythromycin, cyprofloxacin and iopromide also increased rapidly up to tens of ngL -1 within a few days. Conversely, atrazine, caffeine, diclofenac, and to a lesser extent carbamazepine and sucralose, were systematically present in the water samples and showed limited variation in concentrations. For most of the substances studied here, the passive samplers gave reliable average concentrations between the minimal and maximal daily concentrations during the time of deployment. For pesticides, a relatively good correlation was clearly established (R 2 =0.89) between the concentrations obtained by POCIS and those gained from average water samples. A slight underestimation of the concentration by POCIS can be attributed to inappropriate sampling rates extracted from the literature and for our system, and new values are proposed. Considering the all data set, 75% of the results indicate a relatively good agreement between the POCIS and the average water samples concentration (values of the ratio ranging between 0,33 and 3). Note further that this agreement between these concentrations remains valid considering different sampling rates extracted from the literature. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Evaluation of sampling inhalable PM10 particulate matter (≤ 10 μm) using co-located high volume samplers

    International Nuclear Information System (INIS)

    Rajoy, R R S; Dias, J W C; Rego, E C P; Netto, A D Pereira

    2015-01-01

    This paper presents the results of the determination of the concentrations of atmospheric particulate matter ≤ 10 μm (PM10), collected simultaneously by six PM10 high volume samplers from two different manufacturers installed in the same location. Fifteen samples of 24 h were obtained with each equipment at a selected urban area of Rio de Janeiro city. The concentration of PM10 ranged between 10.73 and 54.04 μg m −3 . The samplers were considered comparable to each other, as the adopted methodology presented good repeatability

  17. A New Time Calibration Method for Switched-capacitor-array-based Waveform Samplers.

    Science.gov (United States)

    Kim, H; Chen, C-T; Eclov, N; Ronzhin, A; Murat, P; Ramberg, E; Los, S; Moses, W; Choong, W-S; Kao, C-M

    2014-12-11

    We have developed a new time calibration method for the DRS4 waveform sampler that enables us to precisely measure the non-uniform sampling interval inherent in the switched-capacitor cells of the DRS4. The method uses the proportionality between the differential amplitude and sampling interval of adjacent switched-capacitor cells responding to a sawtooth-shape pulse. In the experiment, a sawtooth-shape pulse with a 40 ns period generated by a Tektronix AWG7102 is fed to a DRS4 evaluation board for calibrating the sampling intervals of all 1024 cells individually. The electronic time resolution of the DRS4 evaluation board with the new time calibration is measured to be ~2.4 ps RMS by using two simultaneous Gaussian pulses with 2.35 ns full-width at half-maximum and applying a Gaussian fit. The time resolution dependencies on the time difference with the new time calibration are measured and compared to results obtained by another method. The new method could be applicable for other switched-capacitor-array technology-based waveform samplers for precise time calibration.

  18. FAST MUSIC SPECTRUM PEAK SEARCH VIA METROPOLIS-HASTINGS SAMPLER

    Institute of Scientific and Technical Information of China (English)

    Guo Qinghua; Liao Guisheng

    2005-01-01

    A fast MUltiple SIgnal Classification (MUSIC) spectrum peak search algorithm is devised, which regards the power of the MUSIC spectrum function as target distribution up to a constant of proportionality, and uses Metropolis-Hastings (MH) sampler, one of the most popular Markov Chain Monte Carlo (MCMC) techniques, to sample from it. The proposed method reduces greatly the tremendous computation and storage costs in conventional MUSIC techniques i.e., about two and four orders of magnitude in computation and storage costs under the conditions of the experiment in the paper respectively.

  19. Sampling of BTX in Hat Yai city using cost effective laboratory-built PCB passive sampler.

    Science.gov (United States)

    Subba, Jas Raj; Thammakhet, Chongdee; Thavarungkul, Panote; Kanatharana, Proespichaya

    2016-08-23

    A laboratory-built printed circuit board (PCB) passive sampler used for the monitoring of xylene and styrene in copy print shops was re-validated for detecting benzene, toluene and xylene (BTX) and applied for the sampling of ambient air from Hat Yai city, Songkhla, Thailand, in the month of November 2014. For monitoring, the PCB passive samplers were exposed to target analytes in 16 locations covering high to low exposure areas. After sampling, the samplers were thermally desorbed and the analytes were trapped by multi-walled carbon nanotubes packed into a micro-preconcentrator coupled to a gas chromatograph (GC) equipped with a flame ionization detector. At the optimum GC operating conditions, the linear dynamic ranges for BTX were 0.06-5.6 µg for benzene, 0.07-2.2 µg for toluene and 0.23-2.5 µg for xylene with R(2) > 0.99 with the limits of detection being 6.6, 6.8 and 19 ng for benzene, toluene and xylene, respectively. The concentrations of BTX in the 16 sampling sites were in the range of N.D.-1.3 ± 1.6, 4.50 ± 0.76-49.6 ± 3.7 and 1.00 ± 0.21-39.6 ± 3.1 µg m(-3), respectively. When compared to past studies, there had been an increase in the benzene concentration.

  20. Performance of an air sampler and a gamma-ray detector in a small unmanned aerial vehicle

    International Nuclear Information System (INIS)

    Roy Poellaenen; Harri Toivonen; Kari Peraejaervi; Tero Karhunen; Petri Smolander; Tarja Ilander; Kimmo Rintala; Tuure Katajainen; Jarkko Niemelae; Marko Juusela; Timo Palos

    2009-01-01

    The performance of an air sampler and a small gamma-ray spectrometer was tested in an unmanned aerial vehicle (UAV) able to carry payload with mass up to 0.5 kg. Operation of the sampler was investigated with the aid of radon progeny normally present in outdoor air. Detection limits for several transuranium nuclides in air are of the order of 0.3 Bq m -3 assuming 0.5 h sampling time and 1 h counting time in direct alpha spectrometry. Unshielded 137 Cs and 60 Co point sources at the ground level were used to test the CsI spectrometer. Detection limits are approximately 1 GBq or larger depending on the flying altitude. (author)

  1. Side-by-side determination of workers' exposure to wood dust with IOM and open-faced samplers.

    Science.gov (United States)

    Cavlović, Anka Ozana; Beljo Lučić, Ružica; Jug, Matija; Radmanović, Kristijan; Bešlić, Ivan

    2013-09-01

    Woodworkers' exposure to airborne particles is measured with different sampling techniques throughout the world. Due to a great number of exposure data obtained with different samplers, European countries have aimed over the last ten years to find a conversion factor for mass concentrations that would render these measurements comparable. Following the accepted EU standards and regulations, we replaced a 25 mm open-faced (OF) filter holder with an IOM head to determine woodworkers' exposure to inhalable dust and establish an IOM/OF sampler ratio that might serve as a reliable factor for converting the existing OF data to IOM dust mass concentration in the industrial environment. For this side-by-side sampling we used personal 25 mm OF (N=29) and IOM (N=29) sampling heads over eight working hours. The obtained IOM/OF ratios ranged between 0.7 and 2.3. However, mass concentrations obtained by IOM and OF samplers did not significantly differ. Our findings suggest that there is no need for conversion of the existing OF data for workers exposed to wood dust, provided that dust mass concentrations in the working environment range between 1 mg m-3 and 7 mg m-3. Future side-by-side measurements should also involve environments with low wood dust mass concentrations.

  2. Comparison of marine sampling methods for organic contaminants: Passive samplers, water extractions, and live oyster deployment.

    Science.gov (United States)

    Raub, Kristin B; Vlahos, Penny; Whitney, Michael

    2015-08-01

    Laboratory and field trials evaluated the efficacy of three methods of detecting aquatic pesticide concentrations. Currently used pesticides: atrazine, metolachlor, and diazinon and legacy pesticide dieldrin were targeted. Pesticides were extracted using solid-phase extraction (SPE) of water samples, titanium plate passive samplers coated in ethylene vinyl acetate (EVA) and eastern oysters (Crassostrea viginica) as biosamplers. A laboratory study assessed the extraction efficiencies and precision of each method. Passive samplers yielded the highest precision of the three methods (RSD: 3-14% EVA plates; 19-60% oysters; and 25-56% water samples). Equilibrium partition coefficients were derived. A significant relationship was found between the concentration in oyster tissue and the ambient aquatic concentration. In the field (Housatonic River, CT (U.S.)) water sampling (n = 5) detected atrazine at 1.61-7.31 μg L(-1), oyster sampling (n = 2×15) detected dieldrin at n.d.-0.096 μg L(-1) SW and the passive samplers (n = 5×3) detected atrazine at 0.97-3.78 μg L(-1) SW and dieldrin at n.d.-0.68 μg L(-1) SW. Copyright © 2015 Elsevier Ltd. All rights reserved.

  3. Bulletin of Materials Science | Indian Academy of Sciences

    Indian Academy of Sciences (India)

    is known as the driving force of crystallization. The driving force of crystallization () provides very important information about the glass-forming ability (GFA) of metallic glasses (MGs). Lesser the driving force of crystallization more is the GFA. The varies linearly with the critical size (). According to Battezzati and ...

  4. Development of an integrated sampler based on direct 222Rn/220Rn progeny sensors in flow-mode for estimating unattached/attached progeny concentration

    International Nuclear Information System (INIS)

    Mishra, Rosaline; Sapra, B.K.; Mayya, Y.S.

    2009-01-01

    A flow-mode integrated sampler consisting of a wire-mesh and filter-paper array along with passive solid state nuclear track detectors has been developed for estimating unattached and attached fraction of 222 Rn/ 220 Rn progeny concentration. The essential element of this sampler is the direct 222 Rn/ 220 Rn progeny sensor (DRPS/DTPS), which is an absorber-mounted-LR115 type nuclear track detector that selectively registers the alpha particles emitted from the progeny deposited on its surface. During sampling at a specified flow-rate, the unattached progeny is captured on the wire-mesh; while the attached progeny gets transmitted and is captured on the filter-paper. The alpha particles emitted by the deposited progeny atoms are registered on the sensors placed at a specified distance facing the wire-mesh and the filter-paper, respectively. The various steps involved in the development of this flow-mode direct progeny sampler such as the optimization of the sampling rate and the distance between the sensor and the deposition substrate are discussed. The sensitivity factor of the DTPS-loaded sampler for 220 Rn progeny deposited on the wire-mesh and filter-paper is found to be 23.77 ± 0.64 (track cm -2 h -1 ) (Bq m -3 ) -1 and 22.30 ± 0.18 (track cm -2 h -1 ) (Bq m -3 ) -1 , respectively; while that of DRPS-loaded sampler for 222 Rn progeny deposition, is 3.03 ± 0.14 (track cm -2 h -1 ) (Bq m -3 ) -1 and 2.08 ± 0.07 (track cm -2 h -1 ) (Bq m -3 ) -1 , respectively. The highlight of this flow-mode sampler is its high sensitivity and that it utilizes the passive technique for estimating the unattached and attached progeny concentration, thus doing away with the alpha counting procedures.

  5. EVALUATION OF MEMBRANE TYPE FOR USE IN DIFFUSION SAMPLERS TO MONITOR GROUND WATER QUALITY

    Science.gov (United States)

    The Discrete Multi-Level Sampler (DMLS®) system has proven to be a useful tool for obtaining discrete interval contaminant concentrations at hazardous waste sites. The DMLS® utilizes dialysis cells, which consist of a polypropylene vial, covered on both ends by a permeable membr...

  6. Food Control and a Citizen Science Approach for Improving Teaching of Genetics in Universities

    Science.gov (United States)

    Borrell, Y. J.; Muñoz-Colmenero, A. M.; Dopico, E.; Miralles, L.; Garcia-Vazquez, E.

    2016-01-01

    A Citizen Science approach was implemented in the laboratory practices of Genetics at the University of Oviedo, related with the engaging topic of Food Control. Real samples of food products consumed by students at home ("students as samplers") were employed as teaching material in three different courses of Genetics during the academic…

  7. A population-based exposure assessment methodology for carbon monoxide: Development of a carbon monoxide passive sampler and occupational dosimeter

    Energy Technology Data Exchange (ETDEWEB)

    Apte, Michael G. [Univ. of California, Berkeley, CA (United States)

    1997-09-01

    Two devices, an occupational carbon monoxide (CO) dosimeter (LOCD), and an indoor air quality (IAQ) passive sampler were developed for use in population-based CO exposure assessment studies. CO exposure is a serious public health problem in the U.S., causing both morbidity and mortality (lifetime mortality risk approximately 10{sup -4}). Sparse data from population-based CO exposure assessments indicate that approximately 10% of the U.S. population is exposed to CO above the national ambient air quality standard. No CO exposure measurement technology is presently available for affordable population-based CO exposure assessment studies. The LOCD and IAQ Passive Sampler were tested in the laboratory and field. The palladium-molybdenum based CO sensor was designed into a compact diffusion tube sampler that can be worn. Time-weighted-average (TWA) CO exposure of the device is quantified by a simple spectrophotometric measurement. The LOCD and IAQ Passive Sampler were tested over an exposure range of 40 to 700 ppm-hours and 200 to 4200 ppm-hours, respectively. Both devices were capable of measuring precisely (relative standard deviation <20%), with low bias (<10%). The LOCD was screened for interferences by temperature, humidity, and organic and inorganic gases. Temperature effects were small in the range of 10°C to 30°C. Humidity effects were low between 20% and 90% RH. Ethylene (200 ppm) caused a positive interference and nitric oxide (50 ppm) caused a negative response without the presence of CO but not with CO.

  8. Application of XAD-2 resin-based passive samplers and SPME–GC–MS/MS analysis for the monitoring of spatial and temporal variations of atmospheric pesticides in Luxembourg

    International Nuclear Information System (INIS)

    Schummer, Claude; Tuduri, Ludovic; Briand, Olivier; Appenzeller, Brice M.; Millet, Maurice

    2012-01-01

    Passive air sampling has been shown to be a very interesting alternative to high-volume sampling by overcoming its disadvantages (size, weight, expensiveness). However, to date, only limited data is available about passive air sampling of current-use pesticides. In order to test if passive samplers allow monitoring of spatial and temporal variations of atmospheric pesticide concentrations, five XAD-2-resin based passive air samplers were deployed at five locations in Luxembourg. Samplers were analyzed using accelerated solvent extraction coupled to solid-phase microextraction and gas chromatography with tandem mass spectrometry. Collected data was used to study the spatial and temporal variations of the concentrations of the compounds. Twenty two pesticides were detected between March and October, while no pesticides were detected from November to February. Highest concentrations were measured on the rural sites, suggesting that the used XAD-2 resin-based passive samplers allow the simultaneous monitoring of multiple current-use pesticides and identifying spatial and temporal variations. - Highlights: ► XAD-2 passive sampling of current-used pesticides. ► Coupling of ASE and SPME–GC–MS/MS for the analysis of pesticides in XAD-2 passive sampling. ► XAD-2 passive samplers suitable for current-used pesticides atmospheric sampling. ► XAD-2 passive samplers suitable for spatial and temporal atmospheric concentrations variations. - XAD-2 passive sampling of current-use pesticides in the atmosphere.

  9. Determining the spatial variability of personal sampler inlet locations.

    Science.gov (United States)

    Vinson, Robert; Volkwein, Jon; McWilliams, Linda

    2007-09-01

    This article examines the spatial variability of dust concentrations within a coal miner's breathing zone and the impact of sampling location at the cap lamp, nose, and lapel. Tests were conducted in the National Institute for Safety and Health Pittsburgh Research Laboratory full-scale, continuous miner gallery using three prototype personal dust monitors (PDM). The dust masses detected by the PDMs were used to calculate the percentage difference of dust mass between the cap lamp and the nose and between the lapel and the nose. The calculated percentage differences of the masses ranged from plus 12% to minus 25%. Breathing zone tests were also conducted in four underground coal mines using the torso of a mannequin to simulate a miner. Coal mine dust was sampled with multi-cyclone sampling cans mounted directly in front of the mannequin near the cap lamp, nose, and lapel. These four coal mine tests found that the spatial variability of dust levels and imprecision of the current personal sampler is a greater influence than the sampler location within the breathing zone. However, a one-sample t-test of this data did find that the overall mean value of the cap lamp/nose ratio was not significantly different than 1 (p-value = 0.21). However, when applied to the overall mean value of the lapel/nose ratio there was a significant difference from 1 (p-value sampling location for coal mine dust samples. But these results suggest that the cap location is slightly more indicative of what is breathed through the nose area.

  10. Two-Stage Variable Sample-Rate Conversion System

    Science.gov (United States)

    Tkacenko, Andre

    2009-01-01

    A two-stage variable sample-rate conversion (SRC) system has been pro posed as part of a digital signal-processing system in a digital com munication radio receiver that utilizes a variety of data rates. The proposed system would be used as an interface between (1) an analog- todigital converter used in the front end of the receiver to sample an intermediatefrequency signal at a fixed input rate and (2) digita lly implemented tracking loops in subsequent stages that operate at v arious sample rates that are generally lower than the input sample r ate. This Two-Stage System would be capable of converting from an input sample rate to a desired lower output sample rate that could be var iable and not necessarily a rational fraction of the input rate.

  11. Soil separator and sampler and method of sampling

    Science.gov (United States)

    O'Brien, Barry H [Idaho Falls, ID; Ritter, Paul D [Idaho Falls, ID

    2010-02-16

    A soil sampler includes a fluidized bed for receiving a soil sample. The fluidized bed may be in communication with a vacuum for drawing air through the fluidized bed and suspending particulate matter of the soil sample in the air. In a method of sampling, the air may be drawn across a filter, separating the particulate matter. Optionally, a baffle or a cyclone may be included within the fluidized bed for disentrainment, or dedusting, so only the finest particulate matter, including asbestos, will be trapped on the filter. The filter may be removable, and may be tested to determine the content of asbestos and other hazardous particulate matter in the soil sample.

  12. astroABC : An Approximate Bayesian Computation Sequential Monte Carlo sampler for cosmological parameter estimation

    Energy Technology Data Exchange (ETDEWEB)

    Jennings, E.; Madigan, M.

    2017-04-01

    Given the complexity of modern cosmological parameter inference where we arefaced with non-Gaussian data and noise, correlated systematics and multi-probecorrelated data sets, the Approximate Bayesian Computation (ABC) method is apromising alternative to traditional Markov Chain Monte Carlo approaches in thecase where the Likelihood is intractable or unknown. The ABC method is called"Likelihood free" as it avoids explicit evaluation of the Likelihood by using aforward model simulation of the data which can include systematics. Weintroduce astroABC, an open source ABC Sequential Monte Carlo (SMC) sampler forparameter estimation. A key challenge in astrophysics is the efficient use oflarge multi-probe datasets to constrain high dimensional, possibly correlatedparameter spaces. With this in mind astroABC allows for massive parallelizationusing MPI, a framework that handles spawning of jobs across multiple nodes. Akey new feature of astroABC is the ability to create MPI groups with differentcommunicators, one for the sampler and several others for the forward modelsimulation, which speeds up sampling time considerably. For smaller jobs thePython multiprocessing option is also available. Other key features include: aSequential Monte Carlo sampler, a method for iteratively adapting tolerancelevels, local covariance estimate using scikit-learn's KDTree, modules forspecifying optimal covariance matrix for a component-wise or multivariatenormal perturbation kernel, output and restart files are backed up everyiteration, user defined metric and simulation methods, a module for specifyingheterogeneous parameter priors including non-standard prior PDFs, a module forspecifying a constant, linear, log or exponential tolerance level,well-documented examples and sample scripts. This code is hosted online athttps://github.com/EliseJ/astroABC

  13. User's guide for polyethylene-based passive diffusion bag samplers to obtain volatile organic compound concentrations in wells. Part I, Deployment, recovery, data interpretation, and quality control and assurance

    Science.gov (United States)

    Vroblesky, Don A.

    2001-01-01

    Diffusion samplers installed in observation wells were found to be capable of yielding representative water samples for chlorinated volatile organic compounds. The samplers consisted of polyethylene bags containing deionized water and relied on diffusion of chlorinated volatile organic compounds through the polyethylene membrane. The known ability of polyethylene to transmit other volatile compounds, such as benzene and toluene, indicates that the samplers can be used for a variety of volatile organic compounds. In wells at the study area, the volatile organic compound concentrations in water samples obtained using the samplers without prior purging were similar to concentrations in water samples obtained from the respective wells using traditional purging and sampling approaches. The low cost associated with this approach makes it a viable option for monitoring large observation-well networks for volatile organic compounds.

  14. Field test of the PNNL Automated Radioxenon Sampler/Analyzer (ARSA)

    International Nuclear Information System (INIS)

    Lagomarsino, R.J.; Ku, E.; Latner, N.; Sanderson, C.G.

    1998-07-01

    As part of the requirements of the Comprehensive Test Ban Treaty (CTBT), the Automated Radioxenon/Sampler Analyzer (ARSA) was designed and engineered by the Pacific Northwest National Laboratory (PNNL). The instrument is to provide near real-time detection and measurement of the radioxenons released into the atmosphere after a nuclear test. Forty-six field tests, designed to determine the performance of the ARSA prototype under simulated field conditions, were conducted at EML from March to December 1997. This final report contains detailed results of the tests with recommendations for improvements in instrument performance

  15. Field test of the PNNL Automated Radioxenon Sampler/Analyzer (ARSA)

    Energy Technology Data Exchange (ETDEWEB)

    Lagomarsino, R.J.; Ku, E.; Latner, N.; Sanderson, C.G.

    1998-07-01

    As part of the requirements of the Comprehensive Test Ban Treaty (CTBT), the Automated Radioxenon/Sampler Analyzer (ARSA) was designed and engineered by the Pacific Northwest National Laboratory (PNNL). The instrument is to provide near real-time detection and measurement of the radioxenons released into the atmosphere after a nuclear test. Forty-six field tests, designed to determine the performance of the ARSA prototype under simulated field conditions, were conducted at EML from March to December 1997. This final report contains detailed results of the tests with recommendations for improvements in instrument performance.

  16. Development and evaluation of an impactor sampler for radioactive aerosol particles

    International Nuclear Information System (INIS)

    Sorimachi, Atsuyuki; Kranrod, Chutima; Chantrarayotha, Supitcha; Tokonami, Shinji

    2008-01-01

    This sampler consists of one impaction stage, which allows separation of airborne particles by 1 μm particle size cut-off point with a 50% probability of impaction, followed by a back-up filter at a flow rate of 1 L min -1 . The particles size more than and less than 1 μm-diameter are collected on the impactor plate at the nozzle side and on the filter, respectively. A Cr-39 detector is mounted on the filter sides of the impaction plate; α particles emitted from the particles less than 1 μm-diameter are counted with the Cr-39 detectors. In order to separate α particles emitted from radon, thoron and their progeny, the Cr-39 detectors are covered with aluminum-vaporized Mylar films. The total thickness of films is adjusted to let their α particles impinge on the Cr-39 detectors. Laboratory tests are going on in terms of the spectral characteristics of α particles before and after passing through the films, the count rate performance of Cr-39 detectors by α particles, the actual collection efficiency of aerosol particles on the impaction plate, and so on. This sampler may be able to supply us with an interesting technique for measuring radon and thoron progeny come from the sources of natural radiation such as the naturally occurred radioactive materials. (author)

  17. A passive air sampler for characterizing the vertical concentration profile of gaseous phase polycyclic aromatic hydrocarbons in near soil surface air.

    Science.gov (United States)

    Zhang, Yuzhong; Deng, Shuxing; Liu, Yanan; Shen, Guofeng; Li, Xiqing; Cao, Jun; Wang, Xilong; Reid, Brian; Tao, Shu

    2011-03-01

    Air-soil exchange is an important process governing the fate of polycyclic aromatic hydrocarbons (PAHs). A novel passive air sampler was designed and tested for measuring the vertical concentration profile of 4 low molecular weight PAHs in gaseous phase (PAH(LMW4)) in near soil surface air. Air at various heights from 5 to 520 mm above the ground was sampled by polyurethane foam disks held in down-faced cartridges. The samplers were tested at three sites: A: an extremely contaminated site, B: a site near A, and C: a background site on a university campus. Vertical concentration gradients were revealed for PAH(LMW4) within a thin layer close to soil surface at the three sites. PAH concentrations either decreased (Site A) or increased (Sites B and C) with height, suggesting either deposition to or evaporation from soils. The sampler is a useful tool for investigating air-soil exchange of gaseous phase semi-volatile organic chemicals. Copyright © 2010 Elsevier Ltd. All rights reserved.

  18. Guidelines for the use of the semipermeable membrane device (SPMD) and the polar organic chemical integrative sampler (POCIS) in environmental monitoring studies

    Science.gov (United States)

    Alvarez, David A.

    2010-01-01

    The success of an environmental monitoring study using passive samplers, or any sampling method, begins in the office or laboratory. Regardless of the specific methods used, the general steps include the formulation of a sampling plan, training of personnel, performing the field (sampling) work, processing the collected samples to recover chemicals of interest, analysis of the enriched extracts, and interpretation of the data. Each of these areas will be discussed in the following sections with emphasis on specific considerations with the use of passive samplers. Water is an extremely heterogeneous matrix both spatially and temporally (Keith, 1991). The mixing and distribution of dissolved organic chemicals in a water body are controlled by the hydrodynamics of the water, the sorption partition coefficients of the chemicals, and the amount of organic matter (suspended sediments, colloids, and dissolved organic carbon) present. In lakes and oceans, stratification because of changes in temperature, water movement, and water composition can occur resulting in dramatic changes in chemical concentrations with depth (Keith, 1991). Additional complications related to episodic events, such as surface runoff, spills, and other point source contamination, can result in isolated or short-lived pulses of contaminants in the water. The application of passive sampling technologies for the monitoring of legacy and emerging organic chemicals in the environment is becoming widely accepted worldwide. The primary use of passive sampling methods for environmental studies is in the area of surface-water monitoring; however, these techniques have been applied to air and groundwater monitoring studies. Although these samplers have no mechanical or moving parts, electrical or fuel needs which require regular monitoring, there are still considerations that need to be understood in order to have a successful study. Two of the most commonly used passive samplers for organic contaminants are

  19. Water sampling at the Berge Helene FPSO at Chinguetti field in Mauritania using passive samplers

    NARCIS (Netherlands)

    Korytar, P.; Galien, van der W.

    2007-01-01

    Three rounds of water sampling were performed at the Berge Helene FPSO at the Chinguetti field in Mauritania using passive samplers attached to the FPSO to determine the levels of contamination that could potentially accumulate in organisms. Two rounds were carried out prior to the commencement of

  20. A passive air sampler for characterizing the vertical concentration profile of gaseous phase polycyclic aromatic hydrocarbons in near soil surface air

    International Nuclear Information System (INIS)

    Zhang Yuzhong; Deng Shuxing; Liu Yanan; Shen Guofeng; Li Xiqing; Cao Jun; Wang Xilong; Reid, Brian; Tao Shu

    2011-01-01

    Air-soil exchange is an important process governing the fate of polycyclic aromatic hydrocarbons (PAHs). A novel passive air sampler was designed and tested for measuring the vertical concentration profile of 4 low molecular weight PAHs in gaseous phase (PAH LMW4 ) in near soil surface air. Air at various heights from 5 to 520 mm above the ground was sampled by polyurethane foam disks held in down-faced cartridges. The samplers were tested at three sites: A: an extremely contaminated site, B: a site near A, and C: a background site on a university campus. Vertical concentration gradients were revealed for PAH LMW4 within a thin layer close to soil surface at the three sites. PAH concentrations either decreased (Site A) or increased (Sites B and C) with height, suggesting either deposition to or evaporation from soils. The sampler is a useful tool for investigating air-soil exchange of gaseous phase semi-volatile organic chemicals. - Research highlights: → Design, field test and calibration of the novel passive air sampler, PAS-V-I. → Vertical concentration gradients of PAH LMW4 within a thin layer close to soil. → Comparison of results between PAS-V-I measurement and fugacity approach. → Potential application of PAS-V-I and further modifications. - A novel passive sampling device was developed and tested for measuring vertical concentration profile of gaseous phase polycyclic aromatic hydrocarbons in near soil surface air.

  1. Pinus nigra and Pinus pinaster needles as passive samplers of polycyclic aromatic hydrocarbons

    International Nuclear Information System (INIS)

    Piccardo, Maria Teresa; Pala, Mauro; Bonaccurso, Bruna; Stella, Anna; Redaelli, Anna; Paola, Gaudenzio; Valerio, Federico

    2005-01-01

    Nine polycyclic aromatic hydrocarbons (PAHs) were analysed in pine needles of different ages (from 6 to 30 months) collected from two species, Pinus nigra and Pinus pinaster, in seven sites located along a transect from a suburban to a rural area of Genoa (Italy). In all sites and for both species, concentrations of more volatile PAHs (phenanthrene, anthracene, fluoranthene, pyrene) were higher than those for other less volatile PAHs, which are preferentially sorbed to airborne particulates (benzo[a]anthracene, chrysene, benzofluoranthenes, benzo[a]pyrene). Concentrations of total PAHs found in P. nigra in the rural sites were, on the average, 2.3 times higher than those in P. pinaster growing nearby. In both pine species, concentrations of volatile PAHs increased according to needle age. Annual trends of other PAHs were more variable, with a general decrease in older needles. P. pinaster needles are shown to be more reliable passive samplers, since they are more resistant to plant diseases, and considerable variation in PAH concentration was observed in P. nigra needles with moulds and fungi. - The suitability of the pine needles as passive air samplers for persistent trace organics is demonstrated

  2. Pinus nigra and Pinus pinaster needles as passive samplers of polycyclic aromatic hydrocarbons

    Energy Technology Data Exchange (ETDEWEB)

    Piccardo, Maria Teresa [Environmental Chemistry Laboratory, National Cancer Research Institute, Genova. L.go Rosanna Benzi n. 10, 16132 Genova (Italy)]. E-mail: chimamb@istge.it; Pala, Mauro [Environmental Chemistry Laboratory, National Cancer Research Institute, Genova. L.go Rosanna Benzi n. 10, 16132 Genova (Italy); Bonaccurso, Bruna [Environmental Chemistry Laboratory, National Cancer Research Institute, Genova. L.go Rosanna Benzi n. 10, 16132 Genova (Italy); Stella, Anna [Environmental Chemistry Laboratory, National Cancer Research Institute, Genova. L.go Rosanna Benzi n. 10, 16132 Genova (Italy); Redaelli, Anna [Environmental Chemistry Laboratory, National Cancer Research Institute, Genova. L.go Rosanna Benzi n. 10, 16132 Genova (Italy); Paola, Gaudenzio [Botany Department, Genoa University, C.so Dogali 1 canc., 16136 Genova (Italy); Valerio, Federico [Environmental Chemistry Laboratory, National Cancer Research Institute, Genova. L.go Rosanna Benzi n. 10, 16132 Genova (Italy)

    2005-01-01

    Nine polycyclic aromatic hydrocarbons (PAHs) were analysed in pine needles of different ages (from 6 to 30 months) collected from two species, Pinus nigra and Pinus pinaster, in seven sites located along a transect from a suburban to a rural area of Genoa (Italy). In all sites and for both species, concentrations of more volatile PAHs (phenanthrene, anthracene, fluoranthene, pyrene) were higher than those for other less volatile PAHs, which are preferentially sorbed to airborne particulates (benzo[a]anthracene, chrysene, benzofluoranthenes, benzo[a]pyrene). Concentrations of total PAHs found in P. nigra in the rural sites were, on the average, 2.3 times higher than those in P. pinaster growing nearby. In both pine species, concentrations of volatile PAHs increased according to needle age. Annual trends of other PAHs were more variable, with a general decrease in older needles. P. pinaster needles are shown to be more reliable passive samplers, since they are more resistant to plant diseases, and considerable variation in PAH concentration was observed in P. nigra needles with moulds and fungi. - The suitability of the pine needles as passive air samplers for persistent trace organics is demonstrated.

  3. Performance evaluation and accuracy of passive capillary samplers (PCAPs) for estimating real-time drainage water fluxes

    Science.gov (United States)

    Successful monitoring of pollutant transport through the soil profile requires accurate, reliable, and appropriate instrumentation to measure amount of drainage water or flux within the vadose layer. We evaluated the performance and accuracy of automated passive capillary wick samplers (PCAPs) for ...

  4. High-frequency, long-duration water sampling in acid mine drainage studies: a short review of current methods and recent advances in automated water samplers

    Science.gov (United States)

    Chapin, Thomas

    2015-01-01

    Hand-collected grab samples are the most common water sampling method but using grab sampling to monitor temporally variable aquatic processes such as diel metal cycling or episodic events is rarely feasible or cost-effective. Currently available automated samplers are a proven, widely used technology and typically collect up to 24 samples during a deployment. However, these automated samplers are not well suited for long-term sampling in remote areas or in freezing conditions. There is a critical need for low-cost, long-duration, high-frequency water sampling technology to improve our understanding of the geochemical response to temporally variable processes. This review article will examine recent developments in automated water sampler technology and utilize selected field data from acid mine drainage studies to illustrate the utility of high-frequency, long-duration water sampling.

  5. Two models of minimalist, incremental syntactic analysis.

    Science.gov (United States)

    Stabler, Edward P

    2013-07-01

    Minimalist grammars (MGs) and multiple context-free grammars (MCFGs) are weakly equivalent in the sense that they define the same languages, a large mildly context-sensitive class that properly includes context-free languages. But in addition, for each MG, there is an MCFG which is strongly equivalent in the sense that it defines the same language with isomorphic derivations. However, the structure-building rules of MGs but not MCFGs are defined in a way that generalizes across categories. Consequently, MGs can be exponentially more succinct than their MCFG equivalents, and this difference shows in parsing models too. An incremental, top-down beam parser for MGs is defined here, sound and complete for all MGs, and hence also capable of parsing all MCFG languages. But since the parser represents its grammar transparently, the relative succinctness of MGs is again evident. Although the determinants of MG structure are narrowly and discretely defined, probabilistic influences from a much broader domain can influence even the earliest analytic steps, allowing frequency and context effects to come early and from almost anywhere, as expected in incremental models. Copyright © 2013 Cognitive Science Society, Inc.

  6. Operating manual for Ford's Farm Range air samplers

    International Nuclear Information System (INIS)

    Glissmeyer, J.A.; Halverson, M.A.

    1980-10-01

    An air-sampling program was designed for a target enclosure at the Ford's Farm Range, Aberdeen Proving Ground, Maryland, where the Army test-fires tungsten and depleted-uranium armor penetrators. The primary potential particle inhalation hazard is depleted uranium. The sampling program includes workplace and filtered exhaust air sampling. Conventional isokinetic stack sampling was employed for the filtered exhaust air. Because of the need for rapid monitor response to concentration increases and decreases, conventional radioactive particle monitors were not used. Instead, real-time aerosol monitors employing a light-scattering technique were used for monitors requiring a fast response. For other monitoring functions, piezoelectric and beta-attenuation respirable-particle sampling techniques were used. The application of these technologies to the monitoring of airborne radioactive contaminants is addressed. Sampler installation and operation are detailed

  7. Sources and distribution of organic compounds using passive samplers in Lake Mead National Recreation Area, Nevada and Arizona, and their implications for potential effects on aquatic biota.

    Science.gov (United States)

    Rosen, Michael R.; Alvarez, David A.; Goodbred, Steven L.; Leiker, Thomas J.; Patino, Reynaldo

    2009-01-01

    Th e delineation of lateral and vertical gradients of organic contaminants in lakes is hampered by low concentrations and nondetection of many organic compounds in water. Passive samplers (semipermeable membrane devices [SPMDs] and polar organic chemical integrative samplers [POCIS]) are well suited for assessing gradients because they can detect synthetic organic

  8. Direct analysis of airborne mite allergen (Der f1) in the residential atmosphere by chemifluorescent immunoassay using bioaerosol sampler.

    Science.gov (United States)

    Miyajima, Kumiko; Suzuki, Yurika; Miki, Daisuke; Arai, Moeka; Arakawa, Takahiro; Shimomura, Hiroji; Shiba, Kiyoko; Mitsubayashi, Kohji

    2014-06-01

    Dermatophagoides farinae allergen (Der f1) is one of the most important indoor allergens associated with allergic diseases in humans. Mite allergen Der f1 is usually associated with particles of high molecular weight; thus, Der f1 is generally present in settled dust. However, a small quantity of Der f1 can be aerosolized and become an airborne component. Until now, a reliable method of detecting airborne Der f1 has not been developed. The aim of this study was to develop a fiber-optic chemifluorescent immunoassay for the detection of airborne Der f1. In this method, the Der f1 concentration measured on the basis of the intensity of fluorescence amplified by an enzymatic reaction between the labeled enzyme by a detection antibody and a fluorescent substrate. The measured Der f1 concentration was in the range from 0.49 to 250 ng/ml and a similar range was found by enzyme-linked immunosorbent assay (ELISA). This method was proved to be highly sensitive to Der f1 compared with other airborne allergens. For the implementation of airborne allergen measurement in a residential environment, a bioaerosol sampler was constructed. The airborne allergen generated by a nebulizer was conveyed to a newly sampler we developed for collecting airborne Der f1. The sampler was composed of polymethyl methacrylate (PMMA) cells for gas/liquid phases and some porous membranes which were sandwiched in between the two phases. Der f1 in air was collected by the sampler and measured using the fiber-optic immunoassay system. The concentration of Der f1 in aerosolized standards was in the range from 0.125 to 2.0 mg/m(3) and the collection rate of the device was approximately 0.2%. © 2013 Elsevier B.V. All rights reserved.

  9. PM10 sampler deposited air particulates: Ascertaining uniformity of sample on filter through rotated exposure to radiation

    International Nuclear Information System (INIS)

    Owoade, Oyediran K.; Olise, Felix S.; Obioh, Imoh B.; Olaniyi, Hezekiah B.; Bolzacchini, Ezio; Ferrero, Luca; Perrone, Grazia

    2006-01-01

    For reproducibility of analytical results of samples deposited on filters using PM 10 sampler, homogeneity of the sample on the filter is very important especially when the size of the X-ray beam for the analysis is less than the size of filter. It is against this background that the air particulate samples collected on using PM 10 samplers are analysed to determine the elemental concentrations. Each sample was divided into four quadrants and each was analysed under same conditions to determine if the particles were deposited uniformly over the filter. Each analysis was done using EDXRF technique. The spectrometer consists of four secondary targets, which are automatically switched to in sequence in analysing each sample. The concentration of various elements detected was determined using TURBOQUANT (a brand name for a SPECTRO method which is used for screening analysis). Sixteen elements were detected in every sample. Results show that there was less than 10% deviation in the concentrations in different quadrants. There were a few elements like Ba, Cs, etc., which have deviation greater than 20%. The concentrations of these latter elements were close to detection limits of the spectrometer. We conclude that the analytical result of particulate samples deposited on filters by the PM 10 sampler can be reliable in terms of the homogeneity of the deposition. For such analytes with low concentrations, it would be important that the sampling time be increased to allow for higher mass deposition on the filter

  10. A minimally invasive micro sampler for quantitative sampling with an ultrahigh-aspect-ratio microneedle and a PDMS actuator.

    Science.gov (United States)

    Liu, Long; Wang, Yan; Yao, Jinyuan; Yang, Cuijun; Ding, Guifu

    2016-08-01

    This study describes a novel micro sampler consisting of an ultrahigh-aspect-ratio microneedle and a PDMS actuator. The microneedle was fabricated by a new method which introduced reshaped photoresist technology to form a flow channel inside. The microneedle includes two parts: shaft and pedestal. In this study, the shaft length is 1500 μm with a 45° taper angle on the tip and pedestal is 1000 μm. Besides, the shaft and pedestal are connected by an arc connection structure with a length of 600 μm. The microneedles have sufficient mechanical strength to insert into skin with a wide safety margin which was proved by mechanics tests. Moreover, a PDMS actuator with a chamber inside was designed and fabricated in this study. The chamber, acting as a reservoir in sampling process as well as providing power, was optimized by finite element analysis (FEA) to decrease dead volume and improve sampling precision. The micro sampler just needs finger press to activate the sampling process as well as used for quantitative micro injection to some extent. And a volume of 31.5 ± 0.8 μl blood was successfully sampled from the ear artery of a rabbit. This micro sampler is suitable for micro sampling for diagnose or therapy in biomedical field.

  11. Simplified unified analysis of switched-RC passive mixers, samplers, and N -Path filters using the adjoint network

    NARCIS (Netherlands)

    Pavan, Shanthi; Klumperink, Eric A.M.

    2017-01-01

    Recent innovations in software defined CMOS radio transceiver architectures heavily rely on high linearity switched-RC sampler and passive-mixer circuits, driven by digitally programmable multiphase clocks. Although seemingly simple, the frequency domain analysis of these linear periodically time

  12. A Field Evaluation of Performance Reference Compound Based Estimates of Cfree Using Water Column Deployed Passive Samplers

    Science.gov (United States)

    Low-Density polyethylene (LDPE) sheets are often used as passive samplers for aquatic environmental monitoring to measure the freely dissolved concentrations of hydrophobic organic contaminants (HOCs). HOCs that are freely dissolved in water (Cfree) will partition into the LDPE u...

  13. Observations on persistent organic pollutants in indoor and outdoor air using passive polyurethane foam samplers

    Science.gov (United States)

    Bohlin, Pernilla; Jones, Kevin C.; Tovalin, Horacio; Strandberg, Bo

    Air quality data of persistent organic pollutants (POPs) indoors and outdoors are sparse or lacking in several parts of the world, often hampered by the cost and inconvenience of active sampling techniques. Cheap and easy passive air sampling techniques are therefore helpful for reconnaissance surveys. As a part of the Megacity Initiative: Local and Global Research Observations (MILAGRO) project in Mexico City Metropolitan Area in 2006, a range of POPs (polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs), organochlorine pesticides (OCPs), and polybrominated diphenyl ethers (PBDEs)) were analyzed in polyurethane foam (PUF) disks used as passive samplers in indoor and outdoor air. Results were compared to those from samplers deployed simultaneously in Gothenburg (Sweden) and Lancaster (United Kingdom). Using sampling rates suggested in the literature, the sums of 13 PAHs in the different sites were estimated to be 6.1-180 ng m -3, with phenanthrene as the predominant compound. Indoor PAH levels tended to be higher in Gothenburg and outdoor levels higher in Mexico City. The sum of PCBs ranged 59-2100 ng m -3, and seemed to be highest indoors in Gothenburg and Lancaster. PBDE levels (sum of seven) ranged 0.68-620 ng m -3, with the highest levels found in some indoor locations. OCPs (i.e. DDTs, HCHs, and chlordanes) were widely dispersed both outdoors and indoors at all three studied areas. In Gothenburg all POPs tended to be higher indoors than outdoors, while indoor and outdoor levels in Mexico City were similar. This could be due to the influence of indoor and outdoor sources, air exchange rates, and lifestyle factors. The study demonstrates how passive samplers can provide quick and cheap reconnaissance data simultaneously at many locations which can shed light on sources and other factors influencing POP levels in air, especially for the gaseous fractions.

  14. Validation of Ogawa passive samplers for the determination of gaseous ammonia concentrations in agricultural settings

    Science.gov (United States)

    Roadman, M. J.; Scudlark, J. R.; Meisinger, J. J.; Ullman, W. J.

    The Ogawa passive sampler (Ogawa USA, Pompano Beach, Florida) is a useful tool for monitoring atmospheric ammonia (NH 3(g)) concentrations and assessing the effects of agricultural waste management practices on NH 3(g) emissions. The Ogawa sampler, with filter-discs impregnated with citric acid, was used to trap and determine NH 3(g) concentrations in a variety of agricultural settings. A wide range of NH 3(g) concentrations can be monitored by varying the sampler exposure time, provided that no more than ˜10 μg of NH 3-N are adsorbed on the acid-coated filters. Concentrations less than 1 μg NH 3-N m -3 can be detected using long deployments (⩽14 days), while concentrations as great as 10 mg NH 3-N m -3 may be determined in very short (e.g. 5 min) deployments. Reproducibility ranged from 5% to 10% over the range of concentrations studied and passive determinations of NH 3(g) were similar to those determined using dilute-acid gas scrubbers. Background levels of NH 3(g) at a non-agricultural site in southern Delaware were typically <1 μg NH 3-N m -3. The air entering a chicken house was 10 μg NH 3-N m -3, reflecting the background levels in agricultural settings in this region. Within the house, concentrations ⩽8.5 mg NH 3-N m -3 were observed, reflecting the high rates of NH 3(g) emission from chicken excreta. Using measured NH 3(g) concentrations and poultry house ventilation rates, we estimate that each broiler grown to production size over 6 weeks contributes approximately 19±3 g of NH 3-N to the atmosphere, a value consistent with other published results.

  15. Multipurpose Sediment Passive Sampler with Improved Tissue Mimicry to Measure the Bioavailable Fraction

    Science.gov (United States)

    2016-11-01

    run by HPLC- DAD . There was a linear relationship between the RDX found in the extract and the amount in the solution (Figures 11 and 12, Raw data can...TNT had occurred in the reaction solution. Moreover, the anion is reactive and can form Meisenheimer complexes with electron rich compounds...The poor recovery was determined to be due to the desorption step since it was found that the samplers efficiently extracted the metals from solution

  16. Sampling trace organic compounds in water: a comparison of a continuous active sampler to continuous passive and discrete sampling methods.

    Science.gov (United States)

    Coes, Alissa L; Paretti, Nicholas V; Foreman, William T; Iverson, Jana L; Alvarez, David A

    2014-03-01

    A continuous active sampling method was compared to continuous passive and discrete sampling methods for the sampling of trace organic compounds (TOCs) in water. Results from each method are compared and contrasted in order to provide information for future investigators to use while selecting appropriate sampling methods for their research. The continuous low-level aquatic monitoring (CLAM) sampler (C.I.Agent® Storm-Water Solutions) is a submersible, low flow-rate sampler, that continuously draws water through solid-phase extraction media. CLAM samplers were deployed at two wastewater-dominated stream field sites in conjunction with the deployment of polar organic chemical integrative samplers (POCIS) and the collection of discrete (grab) water samples. All samples were analyzed for a suite of 69 TOCs. The CLAM and POCIS samples represent time-integrated samples that accumulate the TOCs present in the water over the deployment period (19-23 h for CLAM and 29 days for POCIS); the discrete samples represent only the TOCs present in the water at the time and place of sampling. Non-metric multi-dimensional scaling and cluster analysis were used to examine patterns in both TOC detections and relative concentrations between the three sampling methods. A greater number of TOCs were detected in the CLAM samples than in corresponding discrete and POCIS samples, but TOC concentrations in the CLAM samples were significantly lower than in the discrete and (or) POCIS samples. Thirteen TOCs of varying polarity were detected by all of the three methods. TOC detections and concentrations obtained by the three sampling methods, however, are dependent on multiple factors. This study found that stream discharge, constituent loading, and compound type all affected TOC concentrations detected by each method. In addition, TOC detections and concentrations were affected by the reporting limits, bias, recovery, and performance of each method. Published by Elsevier B.V.

  17. Sampling trace organic compounds in water: a comparison of a continuous active sampler to continuous passive and discrete sampling methods

    Science.gov (United States)

    Coes, Alissa L.; Paretti, Nicholas V.; Foreman, William T.; Iverson, Jana L.; Alvarez, David A.

    2014-01-01

    A continuous active sampling method was compared to continuous passive and discrete sampling methods for the sampling of trace organic compounds (TOCs) in water. Results from each method are compared and contrasted in order to provide information for future investigators to use while selecting appropriate sampling methods for their research. The continuous low-level aquatic monitoring (CLAM) sampler (C.I.Agent® Storm-Water Solutions) is a submersible, low flow-rate sampler, that continuously draws water through solid-phase extraction media. CLAM samplers were deployed at two wastewater-dominated stream field sites in conjunction with the deployment of polar organic chemical integrative samplers (POCIS) and the collection of discrete (grab) water samples. All samples were analyzed for a suite of 69 TOCs. The CLAM and POCIS samples represent time-integrated samples that accumulate the TOCs present in the water over the deployment period (19–23 h for CLAM and 29 days for POCIS); the discrete samples represent only the TOCs present in the water at the time and place of sampling. Non-metric multi-dimensional scaling and cluster analysis were used to examine patterns in both TOC detections and relative concentrations between the three sampling methods. A greater number of TOCs were detected in the CLAM samples than in corresponding discrete and POCIS samples, but TOC concentrations in the CLAM samples were significantly lower than in the discrete and (or) POCIS samples. Thirteen TOCs of varying polarity were detected by all of the three methods. TOC detections and concentrations obtained by the three sampling methods, however, are dependent on multiple factors. This study found that stream discharge, constituent loading, and compound type all affected TOC concentrations detected by each method. In addition, TOC detections and concentrations were affected by the reporting limits, bias, recovery, and performance of each method.

  18. Investigation of a new passive sampler for the detection of munitions compounds in marine and freshwater systems.

    Science.gov (United States)

    Warren, Joseph K; Vlahos, Penny; Smith, Richard; Tobias, Craig

    2018-07-01

    Over the last century, unexploded ordnances have been disposed of in marine shelf systems because of a lack of cost-effective alternatives. Underwater unexploded ordnances have the potential to leak 2,4,6-trinitrotoluene (TNT) and 1,3,5-trinitro-1,3,5-triazine (RDX), commonly used chemical munitions, and contaminate local waters, biota, and sediments. The rate at which this contamination occurs in the environment is relatively unknown, and the cost- and time-prohibitive nature of sampling across sites makes mapping difficult. In the present study we assessed the efficacy of ethylene-vinyl acetate (EVA) for sampling relatively soluble munitions compounds over a range of environmental conditions (i.e., changes in temperature and salinity) and optimized the composition of the passive sampling polymer. The EVA sampler was able to successfully detect ambient concentrations of lingering munitions compounds from field sites containing unexploded ordnances. The sampler affinity for the munitions in terms of an EVA-water partition coefficient was greater than the standard octanol water values for each target compound. Partitioning of compounds onto EVA over the natural ranges of salinity did not change significantly, although uptake varied consistently and predictably with temperature. Increasing the vinyl acetate to ethylene ratio of the polymer corresponded to an increase in uptake capacity, consistent with enhanced dipole-dipole interactions between the munitions and the polymer. This sampler provides a cost-effective means to map and track leakage of unexploded ordnances both spatially and temporally. Environ Toxicol Chem 2018;37:1990-1997. © 2018 SETAC. © 2018 SETAC.

  19. A Hybrid MCMC Sampler for Unconditional Quantile Based on Influence Function

    Directory of Open Access Journals (Sweden)

    El Moctar Laghlal

    2018-05-01

    Full Text Available In this study, we provide a Bayesian estimation method for the unconditional quantile regression model based on the Re-centered Influence Function (RIF. The method makes use of the dichotomous structure of the RIF and estimates a non-linear probability model by a logistic regression using a Gibbs within a Metropolis-Hastings sampler. This approach performs better in the presence of heavy-tailed distributions. Applied to a nationally-representative household survey, the Senegal Poverty Monitoring Report (2005, the results show that the change in the rate of returns to education across quantiles is substantially lower at the primary level.

  20. PM{sub 10} sampler deposited air particulates: Ascertaining uniformity of sample on filter through rotated exposure to radiation

    Energy Technology Data Exchange (ETDEWEB)

    Owoade, Oyediran K. [Environmental Research Laboratory (ERL), Physics Department, Obafemi Awolowo University, Ile-Ife (Nigeria)]. E-mail: oowoade2001@yahoo.com; Olise, Felix S. [Environmental Research Laboratory (ERL), Physics Department, Obafemi Awolowo University, Ile-Ife (Nigeria); Obioh, Imoh B. [Centre for Energy Research, Development (Cerd), Obafemi Awolowo University, Ile-Ife (Nigeria); Olaniyi, Hezekiah B. [Environmental Research Laboratory (ERL), Physics Department, Obafemi Awolowo University, Ile-Ife (Nigeria); Bolzacchini, Ezio [Universita Milano-Bicocca, Dipartimento di Scienze-Ambientali, Pizza della Scienza, Milan (Italy); Ferrero, Luca [Universita Milano-Bicocca, Dipartimento di Scienze-Ambientali, Pizza della Scienza, Milan (Italy); Perrone, Grazia [Universita Milano-Bicocca, Dipartimento di Scienze-Ambientali, Pizza della Scienza, Milan (Italy)

    2006-08-01

    For reproducibility of analytical results of samples deposited on filters using PM{sub 10} sampler, homogeneity of the sample on the filter is very important especially when the size of the X-ray beam for the analysis is less than the size of filter. It is against this background that the air particulate samples collected on using PM{sub 10} samplers are analysed to determine the elemental concentrations. Each sample was divided into four quadrants and each was analysed under same conditions to determine if the particles were deposited uniformly over the filter. Each analysis was done using EDXRF technique. The spectrometer consists of four secondary targets, which are automatically switched to in sequence in analysing each sample. The concentration of various elements detected was determined using TURBOQUANT (a brand name for a SPECTRO method which is used for screening analysis). Sixteen elements were detected in every sample. Results show that there was less than 10% deviation in the concentrations in different quadrants. There were a few elements like Ba, Cs, etc., which have deviation greater than 20%. The concentrations of these latter elements were close to detection limits of the spectrometer. We conclude that the analytical result of particulate samples deposited on filters by the PM{sub 10} sampler can be reliable in terms of the homogeneity of the deposition. For such analytes with low concentrations, it would be important that the sampling time be increased to allow for higher mass deposition on the filter.

  1. Modeling the transport of organic chemicals between polyethylene passive samplers and water in finite and infinite bath conditions.

    Science.gov (United States)

    Tcaciuc, A Patricia; Apell, Jennifer N; Gschwend, Philip M

    2015-12-01

    Understanding the transfer of chemicals between passive samplers and water is essential for their use as monitoring devices of organic contaminants in surface waters. By applying Fick's second law to diffusion through the polymer and an aqueous boundary layer, the authors derived a mathematical model for the uptake of chemicals into a passive sampler from water, in finite and infinite bath conditions. The finite bath model performed well when applied to laboratory observations of sorption into polyethylene (PE) sheets for various chemicals (polycyclic aromatic hydrocarbons, polychlorinated biphenyls [PCBs], and dichlorodiphenyltrichloroethane [DDT]) and at varying turbulence levels. The authors used the infinite bath model to infer fractional equilibration of PCB and DDT analytes in field-deployed PE, and the results were nearly identical to those obtained using the sampling rate model. However, further comparison of the model and the sampling rate model revealed that the exchange of chemicals was inconsistent with the sampling rate model for partially or fully membrane-controlled transfer, which would be expected in turbulent conditions or when targeting compounds with small polymer diffusivities and small partition coefficients (e.g., phenols, some pesticides, and others). The model can be applied to other polymers besides PE as well as other chemicals and in any transfer regime (membrane, mixed, or water boundary layer-controlled). Lastly, the authors illustrate practical applications of this model such as improving passive sampler design and understanding the kinetics of passive dosing experiments. © 2015 SETAC.

  2. A comparison of freshwater mussels and passive samplers as indicators of heavy metal pollution in aquatic systems

    DEFF Research Database (Denmark)

    Søberg, Laila C.; Vollertsen, Jes; Nielsen, Asbjørn Haaning

    2013-01-01

    under controlled conditions in order to determine whether either system was capable of functioning as a reliable source of data on aquatic pollution. The laboratory results indicated that mussels are useful in this context. However, passive samplers will require further development to be useful since...

  3. Use of dust fall filters as passive samplers for metal concentrations in air for communities near contaminated mine tailings.

    Science.gov (United States)

    Beamer, P I; Sugeng, A J; Kelly, M D; Lothrop, N; Klimecki, W; Wilkinson, S T; Loh, M

    2014-05-01

    Mine tailings are a source of metal exposures in many rural communities. Multiple air samples are necessary to assess the extent of exposures and factors contributing to these exposures. However, air sampling equipment is costly and requires trained personnel to obtain measurements, limiting the number of samples that can be collected. Simple, low-cost methods are needed to allow for increased sample collection. The objective of our study was to assess if dust fall filters can serve as passive air samplers and be used to characterize potential exposures in a community near contaminated mine tailings. We placed filters in cylinders, concurrently with active indoor air samplers, in 10 occupied homes. We calculated an estimated flow rate by dividing the mass on each dust fall filter by the bulk air concentration and the sampling duration. The mean estimated flow rate for dust fall filters was significantly different during sampling periods with precipitation. The estimated flow rate was used to estimate metal concentration in the air of these homes, as well as in 31 additional homes in another rural community impacted by contaminated mine tailings. The estimated air concentrations had a significant linear association with the measured air concentrations for beryllium, manganese and arsenic (p passive air sampler is a simple low-cost method to assess potential exposures near contaminated mining sites.

  4. Sadhana | Indian Academy of Sciences

    Indian Academy of Sciences (India)

    Home; Journals; Sadhana. Sirus Mohammadi. Articles written in Sadhana. Volume 39 Issue 4 August 2014 pp 819-841. Optimal sizing of energy storage system for microgrids · Babak Mozafari Sirus Mohammadi · More Details Abstract Fulltext PDF. Microgrids (MGs) are Low Voltage distribution networks comprising various ...

  5. Field monitoring of volatile organic compounds using passive air samplers in an industrial city in Japan

    International Nuclear Information System (INIS)

    Kume, Kazunari; Ohura, Takeshi; Amagai, Takashi; Fusaya, Masahiro

    2008-01-01

    Highly portable, sensitive, and selective passive air samplers were used to investigate ambient volatile organic compound (VOC) levels at multiple sampling sites in an industrial city, Fuji, Japan. We determined the spatial distributions of 27 species of VOCs in three campaigns: Mar (cold season), May (warm season), and Nov (mild season) of 2004. In all campaigns, toluene (geometric mean concentration, 14.0 μg/m 3 ) was the most abundant VOC, followed by acetaldehyde (4.76 μg/m 3 ), and formaldehyde (2.58 μg/m 3 ). The spatial distributions for certain VOCs showed characteristic patterns: high concentrations of benzene and formaldehyde were typically found along major roads, whereas high concentrations of toluene and tetrachloroethylene (PCE) were usually found near factories. The spatial distribution of PCE observed was extremely consistent with the diffusion pattern calculated from Pollutant Release and Transfer Register data and meteorological data, indicated that passive air samplers are useful for determining the sources and distributions of ambient VOCs. - Passive air samplings with hood are useful for determining the identities, sources, and distributions of ambient VOC pollutants

  6. Gibbs Sampler-Based λ-Dynamics and Rao-Blackwell Estimator for Alchemical Free Energy Calculation.

    Science.gov (United States)

    Ding, Xinqiang; Vilseck, Jonah Z; Hayes, Ryan L; Brooks, Charles L

    2017-06-13

    λ-dynamics is a generalized ensemble method for alchemical free energy calculations. In traditional λ-dynamics, the alchemical switch variable λ is treated as a continuous variable ranging from 0 to 1 and an empirical estimator is utilized to approximate the free energy. In the present article, we describe an alternative formulation of λ-dynamics that utilizes the Gibbs sampler framework, which we call Gibbs sampler-based λ-dynamics (GSLD). GSLD, like traditional λ-dynamics, can be readily extended to calculate free energy differences between multiple ligands in one simulation. We also introduce a new free energy estimator, the Rao-Blackwell estimator (RBE), for use in conjunction with GSLD. Compared with the current empirical estimator, the advantage of RBE is that RBE is an unbiased estimator and its variance is usually smaller than the current empirical estimator. We also show that the multistate Bennett acceptance ratio equation or the unbinned weighted histogram analysis method equation can be derived using the RBE. We illustrate the use and performance of this new free energy computational framework by application to a simple harmonic system as well as relevant calculations of small molecule relative free energies of solvation and binding to a protein receptor. Our findings demonstrate consistent and improved performance compared with conventional alchemical free energy methods.

  7. Development of a sensitive passive sampler using indigotrisulfonate for the determination of tropospheric ozone.

    Science.gov (United States)

    Garcia, Gabriel; Allen, Andrew George; Cardoso, Arnaldo Alves

    2010-06-01

    A new sampling and analytical design for measurement of ambient ozone is presented. The procedure is based on ozone absorption and decoloration (at 600 nm) of indigotrisulfonate dye, where ozone adds itself across the carbon-carbon double bond of the indigo. A mean relative standard deviation of 8.6% was obtained using samplers exposed in triplicate, and a correlation coefficient (r) of 0.957 was achieved in parallel measurements using the samplers and a commercial UV ozone instrument. The devices were evaluated in a measurement campaign, mapping spatial and temporal trends of ozone concentrations in a region of southeast Brazil strongly influenced by seasonal agricultural biomass burning, with associated emissions of ozone precursors. Ozone concentrations were highest in rural areas and lowest at an urban site, due to formation during downwind transport and short-term depletion due to titration with nitric oxide. Ozone concentrations showed strong seasonal trends, due to the influences of precursor emissions, relative humidity and solar radiation intensity. Advantages of the technique include ease and speed of use, the ready availability of components, and excellent sensitivity. Achievable temporal resolution of ozone concentrations is 8 hours at an ambient ozone concentration of 3.8 ppb, or 2 hours at a concentration of 15.2 ppb.

  8. Functions and requirements for the INEL light duty utility arm sampler end effector

    International Nuclear Information System (INIS)

    Pace, D.P.; Barnes, G.E.

    1995-02-01

    This sampler end effector system functions and requirements document defines the system functions that the end effector must perform as well as the requirements the design must meet. Safety, quality assurance, operations, environmental conditions, and regulatory requirements have been considered. The main purpose of this document is to provide a basis for the end effector engineering, design, and fabrication activities. The document shall be the living reference document to initiate the development activities and will be updated as system technologies are finalized

  9. Beehold : the colony of the honeybee (Apis mellifera L) as a bio-sampler for pollutants and plant pathogens

    NARCIS (Netherlands)

    Steen, van der J.J.M.

    2016-01-01

    Bio-sampling is a function of bio-indication. Bio-indication with honeybee colonies (Apis mellifera L) is where the research fields of environmental technology and apiculture overlap. The honeybees are samplers of the environment by collecting unintentionally and simultaneously, along

  10. Concentration and movement of neonicotinoids as particulate matter downwind during agricultural practices using air samplers in southwestern Ontario, Canada.

    Science.gov (United States)

    Forero, Luis Gabriel; Limay-Rios, Victor; Xue, Yingen; Schaafsma, Arthur

    2017-12-01

    Atmospheric emissions of neonicotinoid seed treatment insecticides as particulate matter in field crops occur mainly for two reasons: 1) due to abraded dust of treated seed generated during planting using vacuum planters, and 2) as a result of disturbances (tillage or wind events) in the surface of parental soils which release wind erodible soil-bound residues. In the present study, concentration and movement of neonicotinoids as particulate matter were quantified under real conditions using passive and active air samplers. Average neonicotinoid concentrations in Total Suspended Particulate (TSP) using passive samplers were 0.48 ng/cm 2 , trace, trace (LOD 0.80 and 0.04 ng/cm 2 for clothianidin and thiamethoxam, respectively), and using active samplers 16.22, 1.91 and 0.61 ng/m 3 during planting, tillage and wind events, respectively. There was a difference between events on total neonicotinoid concentration collected in particulate matter using either passive or active sampling. Distance of sampling from the source field during planting of treated seed had an effect on total neonicotinoid air concentration. However, during tillage distance did not present an effect on measured concentrations. Using hypothetical scenarios, values of contact exposure for a honey bee were estimated to be in the range from 1.1% to 36.4% of the reference contact LD 50 value of clothianidin of 44 ng/bee. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. High-volume samplers for the assessment of respirable silica content in metal mine dust via direct-on-filter analysis

    CSIR Research Space (South Africa)

    Cauda, EG

    2014-08-01

    Full Text Available -site silica quantification in the samples would allow the identification of high-risk tasks and appropriate dedicated control technologies. With the objective to find more timely silica monitoring solutions, the performance of five different samplers...

  12. Efficacy of passive sampler collection for atmospheric NO2 isotopes under simulated environmental conditions.

    Science.gov (United States)

    Coughlin, Justin G; Yu, Zhongjie; Elliott, Emily M

    2017-07-30

    Nitrogen oxides or NO x (NO x = NO + NO 2 ) play an important role in air quality, atmospheric chemistry, and climate. The isotopic compositions of anthropogenic and natural NO 2 sources are wide-ranging, and they can be used to constrain sources of ambient NO 2 and associated atmospheric deposition of nitrogen compounds. While passive sample collection of NO 2 isotopes has been used in field studies to determine NO x source influences on atmospheric deposition, this approach has not been evaluated for accuracy or precision under different environmental conditions. The efficacy of NO 2 passive sampler collection for NO 2 isotopes was evaluated under varied temperature and relative humidity (RH) conditions in a dynamic flux chamber. The precision and accuracy of the filter NO 2 collection as nitrite (NO 2 - ) for isotopic analysis were determined using a reference NO 2 gas tank and through inter-calibration with a modified EPA Method 7. The bacterial denitrifer method was used to convert 20 μM of collected NO 2 - or nitrate (NO 3 - ) into N 2 O and was carried out on an Isoprime continuous flow isotope ratio mass spectrometer. δ 15 N-NO 2 values determined from passive NO 2 collection, in conditions of 11-34 °C, 1-78% RH, have an overall accuracy and precision of ±2.1 ‰, and individual run precision of ±0.6 ‰. δ 18 O-NO 2 values obtained from passive NO 2 sampler collection, under the same conditions, have an overall precision of ± 1.3 ‰. Suitable conditions for passive sampler collection of NO 2 isotopes are in environments ranging from 11 to 34 °C and 1 to 78% RH. The passive NO 2 isotope measurement technique provides an accurate method to determine variations in atmospheric δ 15 N-NO 2 values and a precise method for determining atmospheric δ 18 O-NO 2 values. The ability to measure NO 2 isotopes over spatial gradients at the same temporal resolution provides a unique perspective on the extent and seasonality of fluctuations in atmospheric NO 2

  13. Numerical estimation of structure constants in the three-dimensional Ising conformal field theory through Markov chain uv sampler

    Science.gov (United States)

    Herdeiro, Victor

    2017-09-01

    Herdeiro and Doyon [Phys. Rev. E 94, 043322 (2016), 10.1103/PhysRevE.94.043322] introduced a numerical recipe, dubbed uv sampler, offering precise estimations of the conformal field theory (CFT) data of the planar two-dimensional (2D) critical Ising model. It made use of scale invariance emerging at the critical point in order to sample finite sublattice marginals of the infinite plane Gibbs measure of the model by producing holographic boundary distributions. The main ingredient of the Markov chain Monte Carlo sampler is the invariance under dilation. This paper presents a generalization to higher dimensions with the critical 3D Ising model. This leads to numerical estimations of a subset of the CFT data—scaling weights and structure constants—through fitting of measured correlation functions. The results are shown to agree with the recent most precise estimations from numerical bootstrap methods [Kos, Poland, Simmons-Duffin, and Vichi, J. High Energy Phys. 08 (2016) 036, 10.1007/JHEP08(2016)036].

  14. Assessment of exposure to composite nanomaterials and development of a personal respiratory deposition sampler for nanoparticles

    Science.gov (United States)

    Cena, Lorenzo

    2011-12-01

    -fiber efficiency of the screens calculated from experimental data was in good agreement with that estimated from theory for particles between 40 and 150 nm but deviated from theory for particles outside of this range. New coefficients for the single-fiber efficiency model were identified that minimized the sum of square error (SSE) between the experimental values and those estimated with the model. Compared to the original theory, the SSE calculated using the modified theory was at least threefold lower for all screens and flow rates. Since nylon fibers produce no significant spectral interference when ashed for spectrometric examination, the ability to accurately estimate collection efficiency of submicrometer particles makes nylon mesh screens an attractive collection substrate for nanoparticles. In the third study, laboratory experiments were conducted to develop a novel nanoparticle respiratory deposition (NRD) sampler that selectively collects nanoparticles in a worker's breathing zone apart from larger particles. The NRD sampler consists of a respirable cyclone fitted with an impactor and a diffusion stage containing eight nylon-mesh screens. A sampling criterion for nano-particulate matter (NPM) was developed and set as the target for the collection efficiency of the NRD sampler. The sampler operates at 2.5 Lpm and fits on a worker's lapel. The cut-off diameter of the impactor was experimentally measured to be 300 nm with a sharpness of 1.53. Loading at typical workplace levels was found to have no significant effect (2-way ANOVA, p=0.257) on the performance of the impactor. The effective deposition of particles onto the diffusion stage was found to match the NPM criterion, showing that a sample collected with the NRD sampler represents the concentration of nanoparticles deposited in the human respiratory system.

  15. Prototype particulate stack sampler with single-cut nozzle and microcomputer calculating/display system

    International Nuclear Information System (INIS)

    Eler, J.C.; Littlefield, L.G.; Tillery, M.I.

    1979-01-01

    A prototype particulate stack sampler (PPSS) has been developed to improve on the existing EPA Method 5 sampling apparatus. Its primary features are (1) higher sampling rate (56 1/min); (2) display (on demand) of all required variables and calculated values by a microcomputer-based calculating and display system; (3) continuous stack gas moisture determination; (4) a virtual impactor nozzle with 3 μm mass median diameter cutpoint which collects fine and coarse particle fractions on separate glass fiber filters; (5) a variable-area inlet to maintain isokinetic sampling conditions; and (6) conversion to stainless steel components from the glass specified by EPA Method 5. The basic sampling techniques of EPA Method 5 have been retained; however, versatility in the form of optional in-stack filters and general modernization of the stack sampler have been provided in the prototype design. Laboratory testing with monodisperse dye aerosols has shown the present variable inlet, virtual impactor nozzle to have a collection efficiency which is less than 77% and significant wall losses. This is primarily due to lack of symmetry in this rectangular jet impactor and short transition lengths dictated by physical design constraints (required passage of the nozzle through a 7.6 cm (3 in) diameter stack port). Electronic components have shown acceptable service in laboratory testing although no field testing of the prototype under a broad range of temperature, humidity, and SO 2 concentration has been undertaken

  16. Calibration and use of the polar organic chemical integrative sampler--a critical review.

    Science.gov (United States)

    Harman, Christopher; Allan, Ian John; Vermeirssen, Etiënne L M

    2012-12-01

    The implementation of strict environmental quality standards for polar organic priority pollutants poses a challenge for monitoring programs. The polar organic chemical integrative sampler (POCIS) may help to address the challenge of measuring low and fluctuating trace concentrations of such organic contaminants, offering significant advantages over traditional sampling. In the present review, the authors evaluate POCIS calibration methods and factors affecting sampling rates together with reported environmental applications. Over 300 compounds have been shown to accumulate in POCIS, including pesticides, pharmaceuticals, hormones, and industrial chemicals. Polar organic chemical integrative sampler extracts have been used for both chemical and biological analyses. Several different calibration methods have been described, which makes it difficult to directly compare sampling rates. In addition, despite the fact that some attempts to correlate sampling rates with the properties of target compounds such as log K(OW) have been met with varying success, an overall model that can predict uptake is lacking. Furthermore, temperature, water flow rates, salinity, pH, and fouling have all been shown to affect uptake; however, there is currently no robust method available for adjusting for these differences. Overall, POCIS has been applied to a wide range of sampling environments and scenarios and has been proven to be a useful screening tool. However, based on the existing literature, a more mechanistic approach is required to increase understanding and thus improve the quantitative nature of the measurements. Copyright © 2012 SETAC.

  17. Emerging investigator series: development and application of polymeric electrospun nanofiber mats as equilibrium-passive sampler media for organic compounds.

    Science.gov (United States)

    Qian, Jiajie; Jennings, Brandon; Cwiertny, David M; Martinez, Andres

    2017-11-15

    We fabricated a suite of polymeric electrospun nanofiber mats (ENMs) and investigated their performance as next-generation passive sampler media for environmental monitoring of organic compounds. Electrospinning of common polymers [e.g., polyacrylonitrile (PAN), polymethyl methacrylate (PMMA), and polystyrene (PS), among others] yielded ENMs with reproducible control of nanofiber diameters (from 50 to 340 nm). The ENM performance was investigated initially with model hydrophilic (aniline and nitrobenzene) and hydrophobic (selected PCB congeners and dioxin) compounds, generally revealing fast chemical uptake into all of these ENMs, which was well described by a one compartment, first-order kinetic model. Typical times to reach 90% equilibrium (t 90% ) were ≤7 days under mixing conditions for all the ENMs and equilibrium timescales suggest that ENMs may be used in the field as an equilibrium-passive sampler, at least for our model compounds. Equilibrium partitioning coefficients (K ENM-W , L kg -1 ) averaged 2 and 4.7 log units for the hydrophilic and hydrophobic analytes, respectively. PAN, PMMA and PS were prioritized for additional studies because they exhibited not only the greatest capacity for simultaneous uptake of the entire model suite (log K ENM-W ∼1.5-6.2), but also fast uptake. For these optimized ENMs, the rates of uptake into PAN and PMMA were limited by aqueous phase diffusion to the nanofiber surface, and the rate-determining step for PS was analyte specific. Sorption isotherms also revealed that the environmental application of these optimized ENMs would occur within the linear uptake regime. We examined the ENM performance for the measurement of pore water concentrations from spiked soil and freshwater sediments. Soil and sediment studies not only yielded reproducible pore water concentrations and comparable values to other passive sampler materials, but also provided practical insights into ENM stability and fouling in such systems

  18. Monitoring of bioaerosol inhalation risks in different environments using a six-stage Andersen sampler and the PCR-DGGE method.

    Science.gov (United States)

    Xu, Zhenqiang; Yao, Maosheng

    2013-05-01

    Increasing evidences show that inhalation of indoor bioaerosols has caused numerous adverse health effects and diseases. However, the bioaerosol size distribution, composition, and concentration level, representing different inhalation risks, could vary with different living environments. The six-stage Andersen sampler is designed to simulate the sampling of different human lung regions. Here, the sampler was used in investigating the bioaerosol exposure in six different environments (student dorm, hospital, laboratory, hotel room, dining hall, and outdoor environment) in Beijing. During the sampling, the Andersen sampler was operated for 30 min for each sample, and three independent experiments were performed for each of the environments. The air samples collected onto each of the six stages of the sampler were incubated on agar plates directly at 26 °C, and the colony forming units (CFU) were manually counted and statistically corrected. In addition, the developed CFUs were washed off the agar plates and subjected to polymerase chain reaction (PCR)-denaturing gradient gel electrophoresis (DGGE) for diversity analysis. Results revealed that for most environments investigated, the culturable bacterial aerosol concentrations were higher than those of culturable fungal aerosols. The culturable bacterial and fungal aerosol fractions, concentration, size distribution, and diversity were shown to vary significantly with the sampling environments. PCR-DGGE analysis indicated that different environments had different culturable bacterial aerosol compositions as revealed by distinct gel band patterns. For most environments tested, larger (>3 μm) culturable bacterial aerosols with a skewed size distribution were shown to prevail, accounting for more than 60 %, while for culturable fungal aerosols with a normal size distribution, those 2.1-4.7 μm dominated, accounting for 20-40 %. Alternaria, Cladosporium, Chaetomium, and Aspergillus were found abundant in most

  19. MiniSipper: a new in situ water sampler for high-resolution, long-duration acid mine drainage monitoring.

    Science.gov (United States)

    Chapin, Thomas P; Todd, Andrew S

    2012-11-15

    Abandoned hard-rock mines can be a significant source of acid mine drainage (AMD) and toxic metal pollution to watersheds. In Colorado, USA, abandoned mines are often located in remote, high elevation areas that are snowbound for 7-8 months of the year. The difficulty in accessing these remote sites, especially during winter, creates challenging water sampling problems and major hydrologic and toxic metal loading events are often under sampled. Currently available automated water samplers are not well suited for sampling remote snowbound areas so the U.S. Geological Survey (USGS) has developed a new water sampler, the MiniSipper, to provide long-duration, high-resolution water sampling in remote areas. The MiniSipper is a small, portable sampler that uses gas bubbles to separate up to 250 five milliliter acidified samples in a long tubing coil. The MiniSipper operates for over 8 months unattended in water under snow/ice, reduces field work costs, and greatly increases sampling resolution, especially during inaccessible times. MiniSippers were deployed in support of an U.S. Environmental Protection Agency (EPA) project evaluating acid mine drainage inputs from the Pennsylvania Mine to the Snake River watershed in Summit County, CO, USA. MiniSipper metal results agree within 10% of EPA-USGS hand collected grab sample results. Our high-resolution results reveal very strong correlations (R(2)>0.9) between potentially toxic metals (Cd, Cu, and Zn) and specific conductivity at the Pennsylvania Mine site. The large number of samples collected by the MiniSipper over the entire water year provides a detailed look at the effects of major hydrologic events such as snowmelt runoff and rainstorms on metal loading from the Pennsylvania Mine. MiniSipper results will help guide EPA sampling strategy and remediation efforts in the Snake River watershed. Published by Elsevier B.V.

  20. MiniSipper: A new in situ water sampler for high-resolution, long-duration acid mine drainage monitoring

    Science.gov (United States)

    Chapin, Thomas P.; Todd, Andrew S.

    2012-01-01

    Abandoned hard-rock mines can be a significant source of acid mine drainage (AMD) and toxic metal pollution to watersheds. In Colorado, USA, abandoned mines are often located in remote, high elevation areas that are snowbound for 7–8 months of the year. The difficulty in accessing these remote sites, especially during winter, creates challenging water sampling problems and major hydrologic and toxic metal loading events are often under sampled. Currently available automated water samplers are not well suited for sampling remote snowbound areas so the U.S. Geological Survey (USGS) has developed a new water sampler, the MiniSipper, to provide long-duration, high-resolution water sampling in remote areas. The MiniSipper is a small, portable sampler that uses gas bubbles to separate up to 250 five milliliter acidified samples in a long tubing coil. The MiniSipper operates for over 8 months unattended in water under snow/ice, reduces field work costs, and greatly increases sampling resolution, especially during inaccessible times. MiniSippers were deployed in support of an U.S. Environmental Protection Agency (EPA) project evaluating acid mine drainage inputs from the Pennsylvania Mine to the Snake River watershed in Summit County, CO, USA. MiniSipper metal results agree within 10% of EPA-USGS hand collected grab sample results. Our high-resolution results reveal very strong correlations (R2 > 0.9) between potentially toxic metals (Cd, Cu, and Zn) and specific conductivity at the Pennsylvania Mine site. The large number of samples collected by the MiniSipper over the entire water year provides a detailed look at the effects of major hydrologic events such as snowmelt runoff and rainstorms on metal loading from the Pennsylvania Mine. MiniSipper results will help guide EPA sampling strategy and remediation efforts in the Snake River watershed.

  1. Comparison of a disposable sorptive sampler with thermal desorption in a gas chromatographic inlet, or in a dedicated thermal desorber, to conventional stir bar sorptive extraction-thermal desorption for the determination of micropollutants in water.

    Science.gov (United States)

    Wooding, Madelien; Rohwer, Egmont R; Naudé, Yvette

    2017-09-01

    The presence of micropollutants in the aquatic environment is a worldwide environmental concern. The diversity of micropollutants and the low concentration levels at which they may occur in the aquatic environment have greatly complicated the analysis and detection of these chemicals. Two sorptive extraction samplers and two thermal desorption methods for the detection of micropollutants in water were compared. A low-cost, disposable, in-house made sorptive extraction sampler was compared to SBSE using a commercial Twister sorptive sampler. Both samplers consisted of polydimethylsiloxane (PDMS) as a sorptive medium to concentrate micropollutants. Direct thermal desorption of the disposable samplers in the inlet of a GC was compared to conventional thermal desorption using a commercial thermal desorber system (TDS). Comprehensive gas chromatography coupled to time-of-flight mass spectrometry (GC × GC-TOFMS) was used for compound separation and identification. Ten micropollutants, representing a range of heterogeneous compounds, were selected to evaluate the performance of the methods. The in-house constructed sampler, with its associated benefits of low-cost and disposability, gave results comparable to commercial SBSE. Direct thermal desorption of the disposable sampler in the inlet of a GC eliminated the need for expensive consumable cryogenics and total analysis time was greatly reduced as a lengthy desorption temperature programme was not required. Limits of detection for the methods ranged from 0.0010 ng L -1 to 0.19 ng L -1 . For most compounds, the mean (n = 3) recoveries ranged from 85% to 129% and the % relative standard deviation (% RSD) ranged from 1% to 58% with the majority of the analytes having a %RSD of less than 30%. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Determination of phenolic compounds in air by using cyclodextrin-silica hybrid microporous composite samplers.

    Science.gov (United States)

    Mauri-Aucejo, Adela R; Ponce-Català, Patricia; Belenguer-Sapiña, Carolina; Amorós, Pedro

    2015-03-01

    An analytical method for the determination of phenolic compounds in air samples based on the use of cyclodextrin-silica hybrid microporous composite samplers is proposed. The method allows the determination of phenol, guaiacol, cresol isomers, eugenol, 4-ethylphenol and 4-ethylguaiacol in workplaces according to the Norm UNE-EN 1076:2009 for active sampling. Therefore, the proposed method offers an alternative for the assessment of the occupational exposure to phenol and cresol isomers. The detection limits of the proposed method are lower than those for the NIOSH Method 2546. Storage time of samples almost reaches 44 days. Recovery values for phenol, guaiacol, o-cresol, m-cresol, p-cresol, 4-ethylguaiacol, eugenol and 4-ethylphenol are 109%, 99%, 102%, 94%, 94%, 91%, 95% and 102%, respectively with a coefficient of variation below 6%. The method has been applied to the assessment of exposure in different areas of a farm and regarding the quantification of these compounds in the vapors generated by burning incense sticks and an essential oil marketed as air fresheners. The acquired results are comparable with those provided from a reference method for a 95% of confidence level. The possible use of these samplers for the sampling of other toxic compounds such as phthalates is evaluated by qualitative analysis of extracts from incense sticks and essential oil samples. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. Assessment of bioavailable fraction of POPS in surface water bodies in Johannesburg City, South Africa, using passive samplers: an initial assessment.

    Science.gov (United States)

    Amdany, Robert; Chimuka, Luke; Cukrowska, Ewa; Kukučka, Petr; Kohoutek, Jiří; Tölgyessy, Peter; Vrana, Branislav

    2014-09-01

    In this study, the semipermeable membrane device (SPMD) passive samplers were used to determine freely dissolved concentrations of polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs) and organochlorine pesticides (OCPs) in selected water bodies situated in and around Johannesburg City, South Africa. The devices were deployed for 14 days at each sampling site in spring and summer of 2011. Time weighted average (TWA) concentrations of the water-borne contaminants were calculated from the amounts of analytes accumulated in the passive samplers. In the area of interest, concentrations of analytes in water ranged from 33.5 to 126.8 ng l(-1) for PAHs, from 20.9 to 120.9 pg l(-1) for PCBs and from 0.2 to 36.9 ng l(-1) for OCPs. Chlorinated pesticides were mainly composed of hexachlorocyclohexanes (HCHs) (0.15-36.9 ng l(-1)) and dichlorodiphenyltrichloromethane (DDT) with its metabolites (0.03-0.55 ng l(-1)). By applying diagnostic ratios of certain PAHs, identification of possible sources of the contaminants in the various sampling sites was performed. These ratios were generally inclined towards pyrogenic sources of pollution by PAHs in all study sites except in the Centurion River (CR), Centurion Lake (CL) and Airport River (AUP) that indicated petrogenic origins. This study highlights further need to map up the temporal and spatial variations of these POPs using passive samplers.

  4. Benthic organisms collected using sediment sampler from the CAPT. BRADY J in the Gulf of Mexico from (NODC Accession 8300082)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Benthic organisms were collected using sediment sampler casts from the CAPT. BRADY J and CAJUN SPECIAL in the Gulf of Mexico from 03 May 1982 to 13 October 1982....

  5. Transient digitizer with displacement current samplers

    Science.gov (United States)

    McEwan, Thomas E.

    1996-01-01

    A low component count, high speed sample gate, and digitizer architecture using the sample gates is based on use of a signal transmission line, a strobe transmission line and a plurality of sample gates connected to the sample transmission line at a plurality of positions. The sample gates include a strobe pickoff structure near the strobe transmission line which generates a charge displacement current in response to propagation of the strobe signal on the strobe transmission line sufficient to trigger the sample gate. The sample gate comprises a two-diode sampling bridge and is connected to a meandered signal transmission line at one end and to a charge-holding cap at the other. The common cathodes are reverse biased. A voltage step is propagated down the strobe transmission line. As the step propagates past a capacitive pickoff, displacement current i=c(dv/dT), flows into the cathodes, driving the bridge into conduction and thereby charging the charge-holding capacitor to a value related to the signal. A charge amplifier converts the charge on the charge-holding capacitor to an output voltage. The sampler is mounted on a printed circuit board, and the sample transmission line and strobe transmission line comprise coplanar microstrips formed on a surface of the substrate. Also, the strobe pickoff structure may comprise a planar pad adjacent the strobe transmission line on the printed circuit board.

  6. Pharmaceuticals, alkylphenols and pesticides in Mediterranean coastal waters: Results from a pilot survey using passive samplers

    OpenAIRE

    Munaron, Dominique; Tapie, Nathalie; Budzinski, Helene; Andral, Bruno; Gonzalez, Jean-louis

    2012-01-01

    21 pharmaceuticals, 6 alkylphenols and 27 hydrophilic pesticides and biocides were investigated using polar organic contaminant integrative samplers (POCIS) during a large-scale study of contamination of French Mediterranean coastal waters. Marine and transitional water-bodies, defined under the EU Water Framework Directive were monitored. Our results show that the French Mediterranean coastal waters were contaminated with a large range of emerging contaminants, detected at low concentrations...

  7. Evaluation of physical sampling efficiency for cyclone-based personal bioaerosol samplers in moving air environments

    OpenAIRE

    Su, Wei-Chung; Tolchinsky, Alexander D.; Chen, Bean T.; Sigaev, Vladimir I.; Cheng, Yung Sung

    2012-01-01

    The need to determine occupational exposure to bioaerosols has notably increased in the past decade, especially for microbiology-related workplaces and laboratories. Recently, two new cyclone-based personal bioaerosol samplers were developed by the National Institute for Occupational Safety and Health (NIOSH) in the USA and the Research Center for Toxicology and Hygienic Regulation of Biopreparations (RCT & HRB) in Russia to monitor bioaerosol exposure in the workplace. Here, a series of wind...

  8. Benthic organisms collected using sediment sampler from the EXCELLENCE in the Gulf of Mexico for 1979-12-19 (NODC Accession 8000603)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Benthic organisms were collected using sediment sampler casts from the EXCELLENCE in the Gulf of Mexico from 19 December 1979 to 19 December 1979. Data were...

  9. Polychlorinated biphenyl (PCB) contamination in Galveston Bay, Texas: Comparing concentrations and profiles in sediments, passive samplers, and fish.

    Science.gov (United States)

    Oziolor, Elias M; Apell, Jennifer N; Winfield, Zach C; Back, Jeffrey A; Usenko, Sascha; Matson, Cole W

    2018-05-01

    The industrialized portion of the Houston Ship Channel (HSC) is heavily contaminated with anthropogenic contaminants, most prominent of which are the polychlorinated biphenyls (PCBs). This contamination has driven adaptive evolution in a keystone species for Galveston Bay, the Gulf killifish (Fundulus grandis). We investigated the geographical extent of PCB impacts by sampling 12 sites, ranging from the heavily industrialized upper portion of the HSC to Galveston Island. At each site, PCB concentrations and profiles were determined in three environmental compartments: sediment, water (polyethylene passive samplers), and fish tissue (resident Gulf killifish). We observed a steep gradient of PCB contamination, ranging from 4.00 to 100,000 ng/g organic carbon in sediment, 290-110,000 ng/g lipid in fish, and 4.5-2300 ng/g polyethylene in passive samplers. The PCB congener profiles in Gulf killifish at the most heavily contaminated sites were shifted toward the higher chlorinated PCBs and were highly similar to the sediment contamination profiles. In addition, while magnitude of total PCB concentrations in sediment and total fish contamination levels were highly correlated between sites, the relative PCB congener profiles in fish and passive samplers were more alike. This strong correlation, along with a lack of dependency of biota-sediment accumulation factors with total contamination rates, confirm the likely non-migratory nature of Gulf killifish and suggest their contamination levels are a good site-specific indicator of contamination in the Galveston Bay area. The spatial gradient of PCB contamination in Galveston Bay was evident in all three matrices studied and was observed effectively using Gulf killifish contamination as an environmentally relevant bioindicator of localized contamination in this environment. Copyright © 2018 Elsevier Ltd. All rights reserved.

  10. Concentrations of pollutants in fogwaters using a Grunow fogwater sampler

    Energy Technology Data Exchange (ETDEWEB)

    Schrimpff, E.; Klemm, O.; Eiden, R.; Frevert, T.; Herrmann, R.

    1984-02-01

    A simple device for sampling fog water is described (modified passive Grunow sampler), and analytical results as were found in rain and fog waters are reported. All samples were taken in the northern part of the Frankenwald mountains (near Bad Steben) from November 1982 until March 1983. Specific conductivity (..mu..Sxcm/sup -1/, 20/sup 0/C), titration acidity, Cl/sup -/, NO/sub 3//sup -/, SO/sub 4//sup 2 -/, total hardness, Ca, Na, Fe, Cd, Pb, TDOC and the polycyclic aromates fluoranthene and 3.4-benzopyrene were continuously higher in fog than in rain water. pH's were remarkably decreased in fog water. Here extreme results were measured in the first two weeks of March with pH 2.5, and acidities proportional2 mequivxl/sup -1/. Possible reasons for such extraordinary concentrations are discussed meteorologically as well as hydrochemically.

  11. In situ bioavailability of DDT and Hg in sediments of the Toce River (Lake Maggiore basin, Northern Italy): accumulation in benthic invertebrates and passive samplers.

    Science.gov (United States)

    Pisanello, Francesca; Marziali, Laura; Rosignoli, Federica; Poma, Giulia; Roscioli, Claudio; Pozzoni, Fiorenzo; Guzzella, Licia

    2016-06-01

    DDT and mercury (Hg) contamination in the Toce River (Northern Italy) was caused by a factory producing technical DDT and using a mercury-cell chlor-alkali plant. In this study, DDT and Hg contamination and bioavailability were assessed by using different approaches: (1) direct evaluation of sediment contamination, (2) assessment of bioaccumulation in native benthic invertebrates belonging to different taxonomic/functional groups, and (3) evaluation of the in situ bioavailability of DDT and Hg using passive samplers. Sampling sites were selected upstream and downstream the industrial plant along the river axis. Benthic invertebrates (Gammaridae, Heptageniidae, and Diptera) and sediments were collected in three seasons and analyzed for DDT and Hg content and the results were used to calculate the biota sediment accumulation factor (BSAF). Polyethylene passive samplers (PEs) for DDT and diffusive gradients in thin films (DGTs) for Hg were deployed in sediments to estimate the concentration of the toxicants in pore water. Analysis for (DDx) were performed using GC-MS. Accuracy was within ±30 % of the certified values and precision was >20 % relative standard deviation (RSD). Total mercury concentrations were determined using an automated Hg mercury analyzer. Precision was >5 % and accuracy was within ±10 % of certified values. The results of all the approaches (analysis of sediment, biota, and passive samplers) showed an increasing contamination from upstream to downstream sites. BSAF values revealed the bioavailability of both contaminants in the study sites, with values up to 49 for DDx and up to 3.1 for Hg. No correlation was found between values in sediments and the organisms. Concentrations calculated using passive samplers were correlated with values in benthic invertebrates, while no correlation was found with concentrations in sediments. Thus, direct analysis of toxicant in sediments does not provide a measurement of bioavailability. On the contrary

  12. Calibration of the Chemcatcher passive sampler for monitoring selected polar and semi-polar pesticides in surface water

    International Nuclear Information System (INIS)

    Gunold, Roman; Schaefer, Ralf Bernhard; Paschke, Albrecht; Schueuermann, Gerrit; Liess, Matthias

    2008-01-01

    Passive sampling is a powerful method for continuous pollution monitoring, but calibration experiments are still needed to generate sampling rates in order to estimate water concentrations for polar compounds. We calibrated the Chemcatcher device with an uncovered SDB-XC Empore disk as receiving phase for 12 polar and semi-polar pesticides in aquatic environments in flow-through tank experiments at two water flow velocities (0.135 m/s and 0.4 m/s). In the 14-day period of exposure the uptake of test substances in the sampler remained linear, and all derived sampling rates R s were in the range of 0.1 to 0.5 L/day. By additionally monitoring the release of two preloaded polar pesticides from the SDB-XC disks over time, very high variation in release kinetics was found, which calls into question the applicability of performance reference compounds. Our study expands the applicability of the Chemcatcher for monitoring trace concentrations of pesticides with frequent occurrence in water. - We calibrated the Chemcatcher passive sampler for current-use polar pesticides in surface waters, allowing its application in future monitoring studies

  13. A rapidly equilibrating, thin film, passive water sampler for organic contaminants; characterization and field testing

    Energy Technology Data Exchange (ETDEWEB)

    St George, Tiffany [Department of Marine Science, University of Connecticut, 1080 Shennecossett Road, Groton, CT 06340 (United States); Department of Science, United States Coast Guard Academy, 27 Mohegan Ave., New London, CT 06320 (United States); Vlahos, Penny, E-mail: penny.vlahos@uconn.ed [Department of Chemistry, University of Connecticut, 55 Eagleville Road, Storrs, CT 06269 (United States); Department of Marine Science, University of Connecticut, 1080 Shennecossett Road, Groton, CT 06340 (United States); Harner, Tom [Science and Technology Branch, Environment Canada, 4905 Dufferin Street, Toronto, Ontario M3H 5T4 (Canada); Helm, Paul [Environmental Monitoring and Reporting Branch, Ontario Ministry of the Environment, 125 Resources Rd, Toronto, Ontario M9P 3V6 (Canada); Wilford, Bryony [Science and Technology Branch, Environment Canada, 4905 Dufferin Street, Toronto, Ontario M3H 5T4 (Canada)

    2011-02-15

    Improving methods for assessing the spatial and temporal resolution of organic compound concentrations in marine environments is important to the sustainable management of our coastal systems. Here we evaluate the use of ethylene vinyl acetate (EVA) as a candidate polymer for thin-film passive sampling in waters of marine environments. Log K{sub EVA-W} partition coefficients correlate well (r{sup 2} = 0.87) with Log K{sub OW} values for selected pesticides and polychlorinated biphenyls (PCBs) where Log K{sub EVA-W} = 1.04 Log K{sub OW} + 0.22. EVA is a suitable polymer for passive sampling due to both its high affinity for organic compounds and its ease of coating at sub-micron film thicknesses on various substrates. Twelve-day field deployments were effective in detecting target compounds with good precision making EVA a potential multi-media fugacity meter. - Research highlights: Calibration and field testing of a thin-film passive sampler in marine systems. Ethylene vinyl acetate (EVA) is effective for a wide spectrum of organic compounds. EVA performs with high precision and reproducibility. EVA is effective in marine systems at environmentally relevant concentrations. EVA is recommended as a multi-media fugacity meter for environmental applications. - An ethylene vinyl acetate (EVA), thin-film passive sampler for the detection of organic compounds in marine environments is calibrated and field tested.

  14. Auto-Gopher: A Wireline Deep Sampler Driven by Piezoelectric Percussive Actuator and EM Rotary Motor

    Science.gov (United States)

    Badescu, Mircea; Ressa, Aaron; Jae Lee, Hyeong; Bar-Cohen, Yoseph; Sherrit, Stewart; Zacny, Kris; Paulsen, Gale L.; Beegle, Luther; Bao, Xiaoqi

    2013-01-01

    The ability to penetrate subsurfaces and perform sample acquisition at depth of meters may be critical for future NASA in-situ exploration missions to bodies in the solar system, including Mars and Europa. A corer/sampler was developed with the goal of enabling acquisition of samples from depths of several meters where if used on Mars would be beyond the oxidized and sterilized zone. For this purpose, we developed a rotary-hammering coring drill, called Auto-Gopher, which employs a piezoelectric actuated percussive mechanism for breaking formations and an electric motor that rotates the bit to remove the powdered cuttings. This sampler is a wireline mechanism that can be fed into and retrieved from the drilled hole using a winch and a cable. It includes an inchworm anchoring mechanism allowing the drill advancement and weight on bit control without twisting the reeling and power cables. The penetration rate is being optimized by simultaneously activating the percussive and rotary motions of the Auto-Gopher. The percussive mechanism is based on the Ultrasonic/Sonic Drill/Corer (USDC) mechanism that is driven by piezoelectric stack and that was demonstrated to require low axial preload. The design and fabrication of this device were presented in previous publications. This paper presents the results of laboratory and field tests and lessons learned from this development.

  15. Personal samplers of bioavailable pesticides integrated with a hair follicle assay of DNA damage to assess environmental exposures and their associated risks in children.

    Science.gov (United States)

    Vidi, Pierre-Alexandre; Anderson, Kim A; Chen, Haiying; Anderson, Rebecca; Salvador-Moreno, Naike; Mora, Dana C; Poutasse, Carolyn; Laurienti, Paul J; Daniel, Stephanie S; Arcury, Thomas A

    2017-10-01

    Agriculture in the United States employs youth ages ten and older in work environments with high pesticide levels. Younger children in rural areas may also be affected by indirect pesticide exposures. The long-term effects of pesticides on health and development are difficult to assess and poorly understood. Yet, epidemiologic studies suggest associations with cancer as well as cognitive deficits. We report a practical and cost-effective approach to assess environmental pesticide exposures and their biological consequences in children. Our approach combines silicone wristband personal samplers and DNA damage quantification from hair follicles, and was tested as part of a community-based participatory research (CBPR) project involving ten Latino children from farmworker households in North Carolina. Our study documents high acceptance among Latino children and their caregivers of these noninvasive sampling methods. The personal samplers detected organophosphates, organochlorines, and pyrethroids in the majority of the participants (70%, 90%, 80%, respectively). Pesticides were detected in all participant samplers, with an average of 6.2±2.4 detections/participant sampler. DNA damage in epithelial cells from the sheath and bulb of plucked hairs follicles was quantified by immunostaining 53BP1-labled DNA repair foci. This method is sensitive, as shown by dose response analyses to γ radiations where the lowest dose tested (0.1Gy) led to significant increased 53BP1 foci density. Immunolabeling of DNA repair foci has significant advantages over the comet assay in that specific regions of the follicles can be analyzed. In this cohort of child participants, significant association was found between the number of pesticide detections and DNA damage in the papilla region of the hairs. We anticipate that this monitoring approach of bioavailable pesticides and genotoxicity will enhance our knowledge of the biological effects of pesticides to guide education programs and

  16. Sensor transition failure in the high flow sampler: Implications for methane emission inventories of natural gas infrastructure.

    Science.gov (United States)

    Howard, Touché; Ferrara, Thomas W; Townsend-Small, Amy

    2015-07-01

    Quantification of leaks from natural gas (NG) infrastructure is a key step in reducing emissions of the greenhouse gas methane (CH4), particularly as NG becomes a larger component of domestic energy supply. The U.S. Environmental Protection Agency (EPA) requires measurement and reporting of emissions of CH4 from NG transmission, storage, and processing facilities, and the high-flow sampler (or high-volume sampler) is one of the tools approved for this by the EPA. The Bacharach Hi-Flow Sampler (BHFS) is the only commercially available high-flow instrument, and it is also used throughout the NG supply chain for directed inspection and maintenance, emission factor development, and greenhouse gas reduction programs. Here we document failure of the BHFS to transition from a catalytic oxidation sensor used to measure low NG (~5% or less) concentrations to a thermal conductivity sensor for higher concentrations (from ~5% to 100%), resulting in underestimation of NG emission rates. Our analysis includes both our own field testing and analysis of data from two other studies (Modrak et al., 2012; City of Fort Worth, 2011). Although this failure is not completely understood, and although we do not know if all BHFS models are similarly affected, sensor transition failure has been observed under one or more of these conditions: (1) Calibration is more than ~2 weeks old; (2) firmware is out of date; or (3) the composition of the NG source is less than ~91% CH4. The extent to which this issue has affected recent emission studies is uncertain, but the analysis presented here suggests that the problem could be widespread. Furthermore, it is critical that this problem be resolved before the onset of regulations on CH4 emissions from the oil and gas industry, as the BHFS is a popular instrument for these measurements. An instrument commonly used to measure leaks in natural gas infrastructure has a critical sensor transition failure issue that results in underestimation of leaks, with

  17. Relative efficiencies of the Burkard 7-Day, Rotorod and Burkard Personal samplers for Poaceae and Urticaceae pollen under field conditions

    DEFF Research Database (Denmark)

    Peel, Robert George; Kennedy, Roy; Smith, Matt

    2014-01-01

    Introduction: In aerobiological studies it is often necessary to compare concentration data recorded with different models of sampling instrument. Sampler efficiency typically varies from device to device, and depends on the target aerosol and local atmospheric conditions. To account for these di...

  18. Development of a passive sampler for gaseous mercury

    Science.gov (United States)

    Gustin, M. S.; Lyman, S. N.; Kilner, P.; Prestbo, E.

    2011-10-01

    Here we describe work toward development of the components of a cost effective passive sampling system for gaseous Hg that could be broadly deployed by nontechnical staff. The passive sampling system included an external shield to reduce turbulence and exposure to precipitation and dust, a diffusive housing that directly protects the collection surface during deployment and handling, and a collection surface. A protocol for cleaning and deploying the sampler and an analytical method were developed. Our final design consisted of a polycarbonate external shield enclosing a custom diffusive housing made from expanded PTFE tubing. Two collection surfaces were investigated, gold sputter-coated quartz plates and silver wires. Research showed the former would require extensive quality control for use, while the latter had interferences with other atmosphere constituents. Although the gold surface exhibited the best performance over space and time, gradual passivation would limit reuse. For both surfaces lack of contamination during shipping, deployment and storage indicated that the handling protocols developed worked well with nontechnical staff. We suggest that the basis for this passive sampling system is sound, but further exploration and development of a reliable collection surface is needed.

  19. Selection of design parameters of diffusion barrier in a passive 222Rn sampler based on activated charcoal adsorption

    International Nuclear Information System (INIS)

    Wei Suxia

    1992-01-01

    A method concerning selection of design parameters of diffusion barrier in a passive 222 Rn sampler based on activated charcoal adsorption. The proper parameter value of diffusion barrier is obtained by means of linearization of 222 Rn adsorption versus the exposure time. Thus, the influence of temperature on measured results may be greatly decreased, and higher sensitivity of the detector may be maintained

  20. A Publications Sampler.

    Science.gov (United States)

    Hess, Sheila

    1984-01-01

    Lists over 100 association publications on topics of: aeronautics and space, aging, arts and architecture, computers, consumer guides, education, educational directories, government and politics, handicapped, health and medicine, housing and land use, libraries, management, recreation and hobbies, science and technology, social issues. A list of…

  1. Preliminary assessment of using tree-tissue analysis and passive-diffusion samplers to evaluate trichloroethene contamination of ground water at Site SS-34N, McChord Air Force Base, Washington, 2001

    Science.gov (United States)

    Cox, S.E.

    2002-01-01

    Two low-cost innovative sampling procedures for characterizing trichloroethene (TCE) contamination in ground water were evaluated for use at McChord Air Force Base (AFB) by the U.S. Geological Survey, in cooperation with the U.S. Air Force McChord Air Force Base Installation Restoration Program, in 2001. Previous attempts to characterize the source of ground-water contamination in the heterogeneous glacial outwash aquifer at McChord site SS-34N using soil-gas surveys, direct-push exploration, and more than a dozen ground-water monitoring wells have had limited success. The procedures assessed in this study involved analysis of tree-tissue samples to map underlying ground-water contamination and deploying passive-diffusion samplers to measure TCE concentrations in existing monitoring wells. These procedures have been used successfully at other U.S. Department of Defense sites and have resulted in cost avoidance and accelerated site characterization. Despite the presence of TCE in ground water at site SS-34N, TCE was not detected in any of the 20 trees sampled at the site during either early spring or late summer sampling. The reason the tree tissue procedure was not successful at the McChord AFB site SS-34N may have been due to an inability of tree roots to extract moisture from a water table 30 feet below the land surface, or that concentrations of TCE in ground water were not large enough to be detectable in the tree tissue at the sampling point. Passive-diffusion samplers were placed near the top, middle, and bottom of screened intervals in three monitoring wells and TCE was observed in all samplers. Concentrations of TCE from the passive-diffusion samplers were generally similar to concentrations found in samples collected in the same wells using conventional pumping methods. In contrast to conventional pumping methods, the collection of ground-water samples using the passive-diffusion samples did not generate waste purge water that would require hazardous

  2. Comparison of the CAS-POL and IOM samplers for determining the knockdown efficiencies of water sprays on float coal dust.

    Science.gov (United States)

    Seaman, Clara E; Shahan, Michael R; Beck, Timothy W; Mischler, Steven E

    2018-03-01

    Float coal dust, generated by mining operations, is distributed throughout mine airways by ventilating air designed to purge gases and respirable dust. Float coal dust poses an explosion hazard in the event of a methane ignition. Current regulation requires the application of inert rock dust in areas subjected to float coal dust in order to mitigate the hazard. An alternate method using water sprays, which have been effective in controlling respirable dust hazards, has been proposed as a way to control float coal dust generated on longwall faces. However, the knockdown efficiency of the proposed water sprays on float coal dust needs to be verified. This study used gravimetric isokinetic Institute of Occupational Medicine (IOM) samplers alongside a real-time aerosol monitor (Cloud Aerosol Spectrometer with polarization; CAS-POL) to study the effects of spray type, operating pressure, and spray orientation on knockdown efficiencies for seven different water sprays. Because the CAS-POL has not been used to study mining dust, the CAS-POL measurements were validated with respect to the IOM samplers. This study found that the CAS-POL was able to resolve the same trends measured by the IOM samplers, while providing additional knockdown information for specific particle size ranges and locations in the test area. In addition, the CAS-POL data was not prone to the same process errors, which may occur due to the handling of the IOM filter media, and was able to provide a faster analysis of the data after testing. This study also determined that pressure was the leading design criteria influencing spray knockdown efficiency, with spray type also having some effect and orientation having little to no effect. The results of this study will be used to design future full-scale float coal dust capture tests involving multiple sprays, which will be evaluated using the CAS-POL.

  3. Radon gas sampler for indoor and soil measurements and its applications

    International Nuclear Information System (INIS)

    Azimi-Garakani, D.; Flores, B.; Piermattei, S.; Susanna, A.F.; Seidel, J.L.; Tommasino, L.; Torri, G.

    1988-01-01

    A national large scale survey of indoor radon (based on an optimised sampling strategy) is needed in Italy to obtain average population dose for use in epidemiological studies. Since in the great majority of cases, one of the most important radon sources is the soil and rock beneath the houses, it would be interesting to combine this survey with measurements of bed-soil radon. With these objectives in mind, a new radon monitor device has been developed consisting of two etched track detectors enclosed in a heat-sealed polyethylene bag. When compared with existing techniques, this radon gas sampler presents several advantages for both indoor and outdoor measurements. As a pilot project, radon gas measurements have been carried out in hundreds of different sites and for several locations; measurements have been made for different years. Typical houses with relatively high radon concentrations have also been thoroughly investigated. (author)

  4. A novel method for sampling the suspended sediment load in the tidal environment using bi-directional time-integrated mass-flux sediment (TIMS) samplers

    Science.gov (United States)

    Elliott, Emily A.; Monbureau, Elaine; Walters, Glenn W.; Elliott, Mark A.; McKee, Brent A.; Rodriguez, Antonio B.

    2017-12-01

    Identifying the source and abundance of sediment transported within tidal creeks is essential for studying the connectivity between coastal watersheds and estuaries. The fine-grained suspended sediment load (SSL) makes up a substantial portion of the total sediment load carried within an estuarine system and efficient sampling of the SSL is critical to our understanding of nutrient and contaminant transport, anthropogenic influence, and the effects of climate. Unfortunately, traditional methods of sampling the SSL, including instantaneous measurements and automatic samplers, can be labor intensive, expensive and often yield insufficient mass for comprehensive geochemical analysis. In estuaries this issue is even more pronounced due to bi-directional tidal flow. This study tests the efficacy of a time-integrated mass sediment sampler (TIMS) design, originally developed for uni-directional flow within the fluvial environment, modified in this work for implementation the tidal environment under bi-directional flow conditions. Our new TIMS design utilizes an 'L' shaped outflow tube to prevent backflow, and when deployed in mirrored pairs, each sampler collects sediment uniquely in one direction of tidal flow. Laboratory flume experiments using dye and particle image velocimetry (PIV) were used to characterize the flow within the sampler, specifically, to quantify the settling velocities and identify stagnation points. Further laboratory tests of sediment indicate that bidirectional TIMS capture up to 96% of incoming SSL across a range of flow velocities (0.3-0.6 m s-1). The modified TIMS design was tested in the field at two distinct sampling locations within the tidal zone. Single-time point suspended sediment samples were collected at high and low tide and compared to time-integrated suspended sediment samples collected by the bi-directional TIMS over the same four-day period. Particle-size composition from the bi-directional TIMS were representative of the array of

  5. Application of an in-situ soil sampler for assessing subsurface biogeochemical dynamics in a diesel-contaminated coastal site during soil flushing operations.

    Science.gov (United States)

    Kwon, Man Jae; O'Loughlin, Edward J; Ham, Baknoon; Hwang, Yunho; Shim, Moojoon; Lee, Soonjae

    2018-01-15

    Subsurface biogeochemistry and contaminant dynamics during the remediation of diesel-contamination by in-situ soil flushing were investigated at a site located in a coastal region. An in-situ sampler containing diesel-contaminated soils separated into two size fractions (fraction were much higher than those in the fraction. Increases in soil TPH in DH1 were consistent with the expected outcomes following well pumping and surfactant injection used to enhance TPH extraction. However, the number of diesel-degrading microorganisms decreased after surfactant injection. 16S-rRNA gene-based analysis also showed that the community composition and diversity depended on both particle size and diesel contamination. The multidisciplinary approach to the contaminated site assessments showed that soil flushing with surfactant enhanced diesel extraction, but negatively impacted in-situ diesel biodegradation as well as groundwater quality. The results also suggest that the in-situ sampler can be an effective monitoring tool for subsurface biogeochemistry as well as contaminant dynamics. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. The effects of rice canopy on the air-soil exchange of polycyclic aromatic hydrocarbons and organochlorine pesticides using paired passive air samplers.

    Science.gov (United States)

    Wang, Yan; Wang, Shaorui; Luo, Chunling; Li, Jun; Ming, Lili; Zhang, Gan; Li, Xiangdong

    2015-05-01

    The rice canopy in paddy fields can influence the air-soil exchange of organic chemicals. We used paired passive air samplers to assess the exchange of polycyclic aromatic hydrocarbons (PAHs) and organochlorine pesticides (OCPs) in a paddy field, South China. Levels of OCPs and light PAHs were generally higher under the canopy than above it. We found that the rice canopy can physically obstruct the evaporation of most OCPs and light PAHs, and can also act as a barrier to the gaseous deposition of p,p'-DDT and heavy PAHs. Paddy fields can behave as a secondary source of OCPs and light PAHs. The homolog patterns of these two types of chemical varied slightly between the air below and above the rice canopy, implying contributions of different sources. Paired passive air samplers can be used effectively to assess the in situ air-soil exchange of PAHs and OCPs in subtropical paddy fields. Copyright © 2015 Elsevier Ltd. All rights reserved.

  7. Eroded Layered Material in Southwest Utopia Planitia

    Science.gov (United States)

    1999-01-01

    Images from the Mars Global Surveyor (MGS) Mars Orbiter Camera (MOC)dramatically illustrate that many places on the red planet have outcrops of layered geologic materials. The two pictures above show the remains of layered material inside craters in southwestern Utopia Planitia (see inset for detailed view). These remnant layers indicate that the craters--and perhaps the plains that surround them--were once buried beneath a deposit that has since been eroded away. This theme of layered outcrops and exhumed craters appears to be one of the dominant observations that MGS MOC has made--to date--about Mars. The origin and composition of the layered material--and its ultimate fate once it was largely eroded away--are unknown. Each of the two pictures shown here covers an area about 4 kilometers (2.5 miles)by 6.3 kilometers (3.9 miles). Illumination is from the lower right. These are subframes of a single MOC image acquired in July 1998 during the MGS Science Phasing Orbits imaging campaign. This figure was presented at the 30th Lunar and Planetary Science Conference in Houston, Texas, March 1999. Malin Space Science Systems and the California Institute of Technology built the MOC using spare hardware from the Mars Observer mission. MSSS operates the camera from its facilities in San Diego, CA. The Jet Propulsion Laboratory's Mars Surveyor Operations Project operates the Mars Global Surveyor spacecraft with its industrial partner, Lockheed Martin Astronautics, from facilities in Pasadena, CA and Denver, CO.

  8. Diurnal measurement of equilibrium equivalent radon/thoron concentration using time integrated flow mode grab sampler

    International Nuclear Information System (INIS)

    Pant, P.; Kandari, T.; Ramola, R.C.; Semwal, C.P.; Prasad, M.

    2018-01-01

    The basic processes which influenced the concentration of radon and thoron decay products are- attachment, recoil and deposition and by the room specific parameters of radon exhalation and ventilation. The freshly formed decay products have a high diffusivities (especially in air) and ability to stick to surfaces. According to UNSCEAR 1977, radon daughters may be combined as the so called equilibrium equivalent concentration which is related to the potential alpha energy distribution concentration. In the present study an effort has been made to see the diurnal variation of radon and thoron progeny concentration using time integrated flow mode sampler

  9. Mars Global Surveyor Radio Science Electron Density Profiles: Interannual Variability and Implications for the Neutral Atmosphere

    Science.gov (United States)

    Bougher, S. W.; Engel, S.; Hinson, D. P.; Murphy, J. R.

    2003-01-01

    The Mars Global Surveyor (MGS) Radio Science (RS) experiment employs an ultrastable oscillator aboard the spacecraft. The signal from the oscillator to Earth is refracted by the Martian ionosphere, allowing retrieval of electron density profiles versus radius and geopotential. The present analysis is carried out on five sets of occultation measurements: (1) four obtained near northern summer solstice (Ls = 74-116, near aphelion) at high northern latitudes (64.7-77.6N), and (2) one set of profiles approaching equinox conditions (Ls = 135- 146) at high southern latitudes (64.7-69.1S). Electron density profiles (95 to 200 km) are examined over a narrow range of solar zenith angles (76.5-86.9 degrees) for local true solar times of (1) 3-4 hours and (2) 12.1 hours. Variations spanning 1-Martian year are specifically examined in the Northern hemisphere.

  10. Benthic organisms collected using sediment sampler from the EXCELLENCE in the Gulf of Mexico from 23 October 1980 to 18 February 1981 (NODC Accession 8100566)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Benthic organisms were collected using sediment sampler casts from the EXCELLENCE in the Gulf of Mexico from 23 October 1980 to 18 February 1981. Data were submitted...

  11. Efficiency of Airborne Sample Analysis Platform (ASAP Bioaerosol Sampler for Pathogen Detection

    Directory of Open Access Journals (Sweden)

    Anurag eSharma

    2015-05-01

    Full Text Available The threat of bioterrorism and pandemics has highlighted the urgency for rapid and reliable bioaerosol detection in different environments. Safeguarding against such threats requires continuous sampling of the ambient air for pathogen detection. In this study we investigated the efficacy of the Airborne Sample Analysis Platform (ASAP 2800 bioaerosol sampler to collect representative samples of air and identify specific viruses suspended as bioaerosols. To test this concept, we aerosolized an innocuous replication-defective bovine adenovirus serotype 3 (BAdV3 in a controlled laboratory environment. The ASAP efficiently trapped the surrogate virus at 5×10E3 plaque-forming units (p.f.u. [2×10E5 genome copy equivalent] concentrations or more resulting in the successful detection of the virus using quantitative PCR. These results support the further development of ASAP for bioaerosol pathogen detection.

  12. Benthic organisms collected using sediment sampler from the EXCELLENCE in the Gulf of Mexico from 31 March 1980 to 02 July 1980 (NODC Accession 8100471)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Benthic organisms were collected using sediment sampler casts from the EXCELLENCE in the Gulf of Mexico from 31 March 1980 to 02 July 1980. Data were submitted by...

  13. Benthic organisms collected using sediment sampler from the EXCELLENCE in the Gulf of Mexico from 30 July 1979 to 16 December 1979 (NODC Accession 8000523)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Benthic organisms were collected using sediment sampler casts from the EXCELLENCE in the Gulf of Mexico from 30 July 1979 to 16 December 1979. Data were submitted by...

  14. Benthic organisms collected using sediment sampler from the SW RESEARCHER in the Gulf of Mexico from 22 September 1977 to 16 December 1977 (NODC Accession 8100224)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Benthic organisms were collected using sediment sampler casts from the SW RESEARCHER in the Gulf of Mexico from 22 September 1977 to 16 December 1977. Data were...

  15. The potential effect of differential ambient and deployment chamber temperatures on PRC derived sampling rates with polyurethane foam (PUF) passive air samplers

    Energy Technology Data Exchange (ETDEWEB)

    Kennedy, Karen, E-mail: k.kennedy@uq.edu.a [University of Queensland, EnTox (National Research Centre for Environmental Toxicology), 39 Kessels Rd., Coopers Plains QLD 4108 (Australia); Hawker, Darryl W. [Griffith University, School of Environment, Nathan QLD 4111 (Australia); Bartkow, Michael E. [University of Queensland, EnTox (National Research Centre for Environmental Toxicology), 39 Kessels Rd., Coopers Plains QLD 4108 (Australia); Carter, Steve [Queensland Health Forensic and Scientific Services, Coopers Plains QLD 4108 (Australia); Ishikawa, Yukari; Mueller, Jochen F. [University of Queensland, EnTox (National Research Centre for Environmental Toxicology), 39 Kessels Rd., Coopers Plains QLD 4108 (Australia)

    2010-01-15

    Performance reference compound (PRC) derived sampling rates were determined for polyurethane foam (PUF) passive air samplers in both sub-tropical and temperate locations across Australia. These estimates were on average a factor of 2.7 times higher in summer than winter. The known effects of wind speed and temperature on mass transfer coefficients could not account for this observation. Sampling rates are often derived using ambient temperatures, not the actual temperatures within deployment chambers. If deployment chamber temperatures are in fact higher than ambient temperatures, estimated sampler-air partition coefficients would be greater than actual partition coefficients resulting in an overestimation of PRC derived sampling rates. Sampling rates determined under measured ambient temperatures and estimated deployment chamber temperatures in summer ranged from 7.1 to 10 m{sup 3} day{sup -1} and 2.2-6.8 m{sup 3} day{sup -1} respectively. These results suggest that potential differences between ambient and deployment chamber temperatures should be considered when deriving PRC-based sampling rates. - Internal deployment chamber temperatures rather than ambient temperatures may be required to accurately estimate PRC-based sampling rates.

  16. Journal of Earth System Science | Indian Academy of Sciences

    Indian Academy of Sciences (India)

    The spectral AOD measurements have been made for the first time over Patiala during multiplatform field campaign ICARB–2006 using a Multi-Wavelength Radiometer (MWR) along with the suspended particulate matter measurements with a high volume sampler. Spectral AOD has higher values in May in comparison to ...

  17. The determination of nitrogen dioxide in ambient air with free hanging filters as passive samplers, and a new calibration method using fritted bubblers

    NARCIS (Netherlands)

    Heeres, P.; Setiawan, R.; Krol, M.C.; Adema, E.H.

    2009-01-01

    This paper describes two new methods for the determination of NO2 in the ambient air. The first method consists of free hanging filters with a diameter of 2.5 cm as passive samplers. The filters are impregnated with triethanolamine to bind NO2. With standard colorimetrical analysis, the amount of

  18. Benthic organisms data collected using sediment sampler casts from NOAA Ship OCEANOGRAPHER in the Chukchi Sea from 1986-09-06 to 1987-10-05 (NODC Accession 8900299)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Benthic organisms data were collected using sediment sampler casts from NOAA Ship OCEANOGRAPHER in the Chukchi Sea from 06 September 1986 to 05 October 1987. Data...

  19. Electrical Conductivity and Chemical Composition of Soil Solution: Comparison of Solution Samplers in Tropical Soils

    Directory of Open Access Journals (Sweden)

    Davi Lopes do Carmo

    2016-01-01

    Full Text Available ABSTRACT Soil solution samplers may have the same working principle, but they differ in relation to chemical and physical characteristics, cost and handling, and these aspects exert influence on the chemical composition of the soil solution obtained. This study was carried out to evaluate, over time, the chemical composition of solutions extracted by Suolo Acqua, with the hydrophilic membrane (HM as a standard, using soils with contrasting characteristics, and to determine the relationship between electrical conductivity (EC and concentration of ions and pH of soil solution samples. This study was carried out under laboratory conditions, using three soils samples with different clay and organic matter (OM contents. Soil solution contents of F−, Cl−, NO−3, Br−, SO42−, Na+, NH4+, K+, Mg2+, Ca2+, were analyzed, as well as inorganic, organic, and total C contents, pH, and EC, in four successive sampling times. Soil solution chemical composition extracted by the Suolo Acqua sampler is similar to that collected by the HM, but the Suolo Acqua extracted more Na+ and soluble organic C than the HM solution. Solution EC, cation and anion concentrations, and soluble C levels are higher in the soil with greater clay and OM contents (Latossolo and Cambissolo in this case. Soil solution composition varied over time, with considerable changes in pH, EC, and nutrient concentrations, especially associated with soil OM. Thus, single and isolated sampling of the soil solution must be avoided, otherwise composition of the soil solution may not be correctly evaluated. Soil solution EC was regulated by pH, as well as the sum of cation and anion concentrations, and the C contents determined in the soil liquid phase.

  20. iDNA screening: Disease vectors as vertebrate samplers.

    Science.gov (United States)

    Kocher, Arthur; de Thoisy, Benoit; Catzeflis, François; Valière, Sophie; Bañuls, Anne-Laure; Murienne, Jérôme

    2017-11-01

    In the current context of global change and human-induced biodiversity decline, there is an urgent need for developing sampling approaches able to accurately describe the state of biodiversity. Traditional surveys of vertebrate fauna involve time-consuming and skill-demanding field methods. Recently, the use of DNA derived from invertebrate parasites (leeches and blowflies) was suggested as a new tool for vertebrate diversity assessment. Bloodmeal analyses of arthropod disease vectors have long been performed to describe their feeding behaviour, for epidemiological purposes. On the other hand, this existing expertise has not yet been applied to investigate vertebrate fauna per se. Here, we evaluate the usefulness of hematophagous dipterans as vertebrate samplers. Blood-fed sand flies and mosquitoes were collected in Amazonian forest sites and analysed using high-throughput sequencing of short mitochondrial markers. Bloodmeal identifications highlighted contrasting ecological features and feeding behaviour among dipteran species, which allowed unveiling arboreal and terrestrial mammals of various body size, as well as birds, lizards and amphibians. Additionally, lower vertebrate diversity was found in sites undergoing higher levels of human-induced perturbation. These results suggest that, in addition to providing precious information on disease vector host use, dipteran bloodmeal analyses may represent a useful tool in the study of vertebrate communities. Although further effort is required to validate the approach and consider its application to large-scale studies, this first work opens up promising perspectives for biodiversity monitoring and eco-epidemiology. © 2017 John Wiley & Sons Ltd.

  1. Estimation of the Human Extrathoracic Deposition Fraction of Inhaled Particles Using a Polyurethane Foam Collection Substrate in an IOM Sampler

    Directory of Open Access Journals (Sweden)

    Darrah K. Sleeth

    2016-03-01

    Full Text Available Extrathoracic deposition of inhaled particles (i.e., in the head and throat is an important exposure route for many hazardous materials. Current best practices for exposure assessment of aerosols in the workplace involve particle size selective sampling methods based on particle penetration into the human respiratory tract (i.e., inhalable or respirable sampling. However, the International Organization for Standardization (ISO has recently adopted particle deposition sampling conventions (ISO 13138, including conventions for extrathoracic (ET deposition into the anterior nasal passage (ET1 and the posterior nasal and oral passages (ET2. For this study, polyurethane foam was used as a collection substrate inside an inhalable aerosol sampler to provide an estimate of extrathoracic particle deposition. Aerosols of fused aluminum oxide (five sizes, 4.9 µm–44.3 µm were used as a test dust in a low speed (0.2 m/s wind tunnel. Samplers were placed on a rotating mannequin inside the wind tunnel to simulate orientation-averaged personal sampling. Collection efficiency data for the foam insert matched well to the extrathoracic deposition convention for the particle sizes tested. The concept of using a foam insert to match a particle deposition sampling convention was explored in this study and shows promise for future use as a sampling device.

  2. Estimation of the Human Extrathoracic Deposition Fraction of Inhaled Particles Using a Polyurethane Foam Collection Substrate in an IOM Sampler.

    Science.gov (United States)

    Sleeth, Darrah K; Balthaser, Susan A; Collingwood, Scott; Larson, Rodney R

    2016-03-07

    Extrathoracic deposition of inhaled particles (i.e., in the head and throat) is an important exposure route for many hazardous materials. Current best practices for exposure assessment of aerosols in the workplace involve particle size selective sampling methods based on particle penetration into the human respiratory tract (i.e., inhalable or respirable sampling). However, the International Organization for Standardization (ISO) has recently adopted particle deposition sampling conventions (ISO 13138), including conventions for extrathoracic (ET) deposition into the anterior nasal passage (ET₁) and the posterior nasal and oral passages (ET₂). For this study, polyurethane foam was used as a collection substrate inside an inhalable aerosol sampler to provide an estimate of extrathoracic particle deposition. Aerosols of fused aluminum oxide (five sizes, 4.9 µm-44.3 µm) were used as a test dust in a low speed (0.2 m/s) wind tunnel. Samplers were placed on a rotating mannequin inside the wind tunnel to simulate orientation-averaged personal sampling. Collection efficiency data for the foam insert matched well to the extrathoracic deposition convention for the particle sizes tested. The concept of using a foam insert to match a particle deposition sampling convention was explored in this study and shows promise for future use as a sampling device.

  3. Development and design of a line imaging spectrometer sampler (LISS) - A user manual

    DEFF Research Database (Denmark)

    Jørgensen, R.N.; Rasmussen, P.

    2002-01-01

    The objective of this report is to develop and describe the software for a Line Imaging Spectrometer Sampler (LISS) to perform measurements of spectra combined with a digital RGB photo of a measurant. Secondly this report should enable users to performmeasurements with the system. The measuring...... are developed as a Graphical User Interfaced (GUI) hosted by Matlab Release 12 from Mathworks. This GUI enables the operator to perform measurements from alldevices simultaneously together with notes specific for the measurant and store all the data in one Matlab data structure. The software includes dynamic...... exposure of the two CCD cameras ensuring optimal use of 16 bit range under unstable illuminationconditions. A routine, handling dark frame subtraction in a robust manner minimising the effect of hot pixels is also included. This report enables a novice user to perform measurements with LISS relatively easy...

  4. Evaluation of PM-10 commercial inlets for new surveillance air sampler

    International Nuclear Information System (INIS)

    Langer, G.

    1986-01-01

    The inlet for the present Rock Flats Plant surveillance sampler does not meet the new but still tentative PM-10 (<10-μm particle mass) criterion for sampling the hazardous fraction of airborne dust. Since this criterion relates mainly to non-radioactive emissions, DOE and EPA are presently in the process of promulgating emission guidelines specifically for non-reactor DOE nuclear facilities. The authors present approach is to select a commercial inlet and modify its, if necessary, to meet the PM-10 criterion, keeping in mind that they may have to recover the dust collected in the inlet. There is no EPA-approved PM-10 inlet design; instead, EPA issued a performance specification. As a nuclear operation, Rocky Flats has to sample continuously to ensure no period remains unmonitored, instead of every sixth day, as set forth by EPA for non-nuclear installations. During this study period, the authors developed an inlet evaluation methodology to meet the above, anticipated EPA requirements. Also, they started testing two potential inlets. 6 references, 2 figures, 1 table

  5. Bacteria, taxonomic code, and other data collected from G.W. PIERCE in North Atlantic Ocean from sediment sampler; 20 February 1976 to 23 March 1976 (NODC Accession 7601642)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Bacteria, taxonomic code, and other data were collected using sediment sampler and other instruments in the North Atlantic Ocean from G.W. PIERCE. Data were...

  6. Zooplankton, chemical, and other data collected from net, sediment sampler, and other instruments from 01 July 1970 to 01 March 1972 in the Great Lakes (NODC Accession 7200691)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Zooplankton, chemical, and other data were collected using net, sediment sampler, and other instruments in the Great Lakes. Data were collected from 01 July 1970 to...

  7. Benthic organisms collected using sediment sampler from the EXCELLENCE and other platforms in the Gulf of Mexico from 1981-12-09 to 1985-08-26 (NODC Accession 8400043)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Benthic organisms were collected using sediment sampler casts from the EXCELLENCE and other platforms in the Gulf of Mexico from 09 December 1981 to 26 August 1985....

  8. Field intercomparison of five types of fogwater collectors

    Energy Technology Data Exchange (ETDEWEB)

    Hering, S.V.; Blumenthal, D.L.; Brewer, R.L.; Gertler, A.; Hoffmann, M.; Kadlecek, J.A.; Pettus, K.

    1987-07-01

    Fog samplers of five different designs were operated simultaneously to assess differences, if any, in measured acidity, analyte concentrations, and liquid water collection efficiencies. Measurements were made at Henninger Flats, a mountainous site at 777 m msl overlooking the Los Angeles, CA basin. Samplers were operated by Aero Vironment, Inc. (Monrovia, CA), the California Institute of Technology (Pasadena, CA), the Desert Research Institute (Reno, NV), Global Geochemistry Corp. (Canoga Park, CA), and the State University of New York Atmospheric Sciences Research Center (Albany, NY). The experimental design included duplicate chemical analyses and data from collocated identical samples, from separated identical samplers, and from the five sampler types. The first three data types represent variability inherent in the experiment, to which the variability among samples types is compared. In general, larger discrepancies were found in the liquid water content data than in the fogwater chemistry. All of the samplers agreed for fogwater pH. Four of the samplers showed reasonable agreement for analyte concentrations. Only three of the samplers showed any agreement for liquid water content. 14 figures.

  9. Dry deposition fluxes and deposition velocities of trace metals in the Tokyo metropolitan area measured with a water surface sampler.

    Science.gov (United States)

    Sakata, Masahiro; Marumoto, Kohji

    2004-04-01

    Dry deposition fluxes and deposition velocities (=deposition flux/atmospheric concentration) for trace metals including Hg, Cd, Cu, Mn, Pb, and Zn in the Tokyo metropolitan area were measured using an improved water surface sampler. Mercury is deposited on the water surface in both gaseous (reactive gaseous mercury, RGM) and particulate (particulate mercury, Hg(p)) forms. The results based on 1 yr observations found that dry deposition plays a significant if not dominant role in trace metal deposition in this urban area, contributing fluxes ranging from 0.46 (Cd) to 3.0 (Zn) times those of concurrent wet deposition fluxes. The deposition velocities were found to be dependent on the deposition of coarse particles larger than approximately 5 microm in diameter on the basis of model calculations. Our analysis suggests that the 84.13% diameter is a more appropriate index for each deposited metal than the 50% diameter in the assumed undersize log-normal distribution, because larger particles are responsible for the flux. The deposition velocities for trace metals other than mercury increased exponentially with an increase in their 84.13% diameters. Using this regression equation, the deposition velocities for Hg(p) were estimated from its 84.13% diameter. The deposition fluxes for Hg(p) calculated from the estimated velocities tended to be close to the mercury fluxes measured with the water surface sampler during the study periods except during summer.

  10. Maturity group classification and maturity locus genotyping of early-maturing soybean varieties from high-latitude cold regions.

    Science.gov (United States)

    Jia, Hongchang; Jiang, Bingjun; Wu, Cunxiang; Lu, Wencheng; Hou, Wensheng; Sun, Shi; Yan, Hongrui; Han, Tianfu

    2014-01-01

    With the migration of human beings, advances of agricultural sciences, evolution of planting patterns and global warming, soybeans have expanded to both tropical and high-latitude cold regions (HCRs). Unlike other regions, HCRs have much more significant and diverse photoperiods and temperature conditions over seasons or across latitudes, and HCR soybeans released there show rich diversity in maturity traits. However, HCR soybeans have not been as well classified into maturity groups (MGs) as other places. Therefore, it is necessary to identify MGs in HCRs and to genotype the maturity loci. Local varieties were collected from the northern part of Northeast China and the far-eastern region of Russia. Maturity group reference (MGR) soybeans of MGs MG000, MG00, and MG0 were used as references during field experiments. Both local varieties and MGR soybeans were planted for two years (2010-2011) in Heihe (N 50°15', E 127°27', H 168.5 m), China. The days to VE (emergence), R1 (beginning bloom) and R7 (beginning maturity) were recorded and statistically analyzed. Furthermore, some varieties were further genotyped at four molecularly-identified maturity loci E1, E2, E3 and E4. The HCR varieties were classified into MG0 or even more early-maturing. In Heihe, some varieties matured much earlier than MG000, which is the most early-maturing known MG, and clustered into a separate group. We designated the group as MG0000, following the convention of MGs. HCR soybeans had relatively stable days to beginning bloom from emergence. The HCR varieties diversified into genotypes of E1, E2, E3 and E4. These loci had different effects on maturity. HCRs diversify early-maturing MGs of soybean. MG0000, a new MG that matures much earlier than known MGs, was developed. HCR soybean breeding should focus more on shortening post-flowering reproductive growth. E1, E2, E3, and E4 function differentially.

  11. Use of maternal information for QTL detection in a (granddaughter design

    Directory of Open Access Journals (Sweden)

    Boichard Didier

    2002-05-01

    Full Text Available Abstract In a (granddaughter design, maternal information is often neglected because the number of progeny per dam is limited. The number of dams per maternal grandsire (MGS, however, could be large enough to contribute to QTL detection. But dams and MGS usually are not genotyped, there are two recombination opportunities between the MGS and the progeny, and at a given location, only half the progeny receive a MGS chromosomal segment. A 3-step procedure was developed to estimate: (1 the marker phenotypes probabilities of the MGS; (2 the probability of each possible MGS haplotype; (3 the probabilities that the progeny receives either the first, or second MGS segment, or a maternal grandam segment. These probabilities were used for QTL detection in a linear model including the effects of sire, MGS, paternal QTL, MGS QTL and maternal grandam QTL. Including the grandam QTL effect makes it possible to detect QTL in the grandam population, even when MGS are not informative. The detection power, studied by simulation, was rather high, provided that MGS family size was greater than 50. Using maternal information in the French dairy cattle granddaughter design made it possible to detect 23 additional QTL genomewise significant.

  12. Stress analysis of jacks, frame and bearing connections, and drill rod for core sampler truck No. 2

    International Nuclear Information System (INIS)

    Ziada, H.H.

    1995-01-01

    This analysis evaluates the structural design adequacy of several components and connections for the rotary mode core sampler truck (RMCST) No. 2. This analysis was requested by the Characterization Equipment Group (WHC 1994a). The components addressed in this report are listed below: front jack assembly and connection to the truck chassis; rear jack assembly and connection to the truck chassis; center outrigger jacks and connection to the truck chassis; lower frame assembly and connection to the truck chassis; bolt connections for bearing plate assembly (for path of maximum load); traverse slide brackets and mounting of the traverse jack cylinders; and drill rod (failure loads)

  13. Stratospheric Air Sub-sampler (SAS) and its application to analysis of Delta O-17(CO2) from small air samples collected with an AirCore

    NARCIS (Netherlands)

    Mrozek, Dorota Janina; van der Veen, Carina; Hofmann, Magdalena E. G.; Chen, Huilin; Kivi, Rigel; Heikkinen, Pauli; Rockmann, Thomas

    2016-01-01

    We present the set-up and a scientific application of the Stratospheric Air Sub-sampler (SAS), a device to collect and to store the vertical profile of air collected with an AirCore (Karion et al., 2010) in numerous sub-samples for later analysis in the laboratory. The SAS described here is a 20m

  14. SyPRID sampler: A large-volume, high-resolution, autonomous, deep-ocean precision plankton sampling system

    Science.gov (United States)

    Billings, Andrew; Kaiser, Carl; Young, Craig M.; Hiebert, Laurel S.; Cole, Eli; Wagner, Jamie K. S.; Van Dover, Cindy Lee

    2017-03-01

    The current standard for large-volume (thousands of cubic meters) zooplankton sampling in the deep sea is the MOCNESS, a system of multiple opening-closing nets, typically lowered to within 50 m of the seabed and towed obliquely to the surface to obtain low-spatial-resolution samples that integrate across 10 s of meters of water depth. The SyPRID (Sentry Precision Robotic Impeller Driven) sampler is an innovative, deep-rated (6000 m) plankton sampler that partners with the Sentry Autonomous Underwater Vehicle (AUV) to obtain paired, large-volume plankton samples at specified depths and survey lines to within 1.5 m of the seabed and with simultaneous collection of sensor data. SyPRID uses a perforated Ultra-High-Molecular-Weight (UHMW) plastic tube to support a fine mesh net within an outer carbon composite tube (tube-within-a-tube design), with an axial flow pump located aft of the capture filter. The pump facilitates flow through the system and reduces or possibly eliminates the bow wave at the mouth opening. The cod end, a hollow truncated cone, is also made of UHMW plastic and includes a collection volume designed to provide an area where zooplankton can collect, out of the high flow region. SyPRID attaches as a saddle-pack to the Sentry vehicle. Sentry itself is configured with a flight control system that enables autonomous survey paths to low altitudes. In its verification deployment at the Blake Ridge Seep (2160 m) on the US Atlantic Margin, SyPRID was operated for 6 h at an altitude of 5 m. It recovered plankton samples, including delicate living larvae, from the near-bottom stratum that is seldom sampled by a typical MOCNESS tow. The prototype SyPRID and its next generations will enable studies of plankton or other particulate distributions associated with localized physico-chemical strata in the water column or above patchy habitats on the seafloor.

  15. Development of an automatic smear sampler and a polymer film for surface radioactive contamination assay

    International Nuclear Information System (INIS)

    Seo, B.-K.; Lee, K.-W.; Woo, Z.-H.; Jeong, K.-S.; Oh, W.-Z.; Han, M.-J.

    2004-01-01

    Measurement of the surface contamination by an indirect method is subject to the various kinds of error according to the sampling person and needs much time and effort in the sampling and assay. In this research, an automatic smear sampler is developed. It improved efficiency for assay work of surface contamination level achieved periodically in a radiation controlled area. Using an automatic smear sampler developed, it is confirmed that radioactive contaminated materials are uniformly transferred to smear paper more than any sampling method by an operator. Also, Solid scintillation proximity membranes were prepared for measuring the amount of radioactive contamination in laboratories contaminated by the low energy beta-ray emitter, such as 3 H and 14 C. Polysulfone scintillation proximity membranes were prepared by impregnating Cerium Activated Yttrium Silicate (CAYS), an inorganic fluor, in a membrane structure. The inorganic fluor-impregnated membranes were applied to detect the radioactive surface contamination. The preparation of membranes was divided into two processes. A supporting polymer film was made of casting solutions consisting of polysulfone and solvent, their cast film being solidified by vacuum evaporation. CAYS-dispersed polymer solutions were cast over the first, solidified polymer films and coagulated either by evaporating solvent in the solution with non-solvent in a coagulation bath. The prepared membranes had two distinguished, but tightly attached, double layers : one is the supporting layer of dense polymer film and the other results revealed that the prepared membranes were efficient to monitor radioactive contamination with reliable counting ability. For enhancement of pick-up and measurement efficiency, the membrane was prepared with the condition of different membrane solidification. The scintillation produced by interaction with radiation and CAYS was measured with photomultiplier tube. The test results showed that the prepared

  16. The Size of Mars' Fluid Core From Mars k2 Love Number Obtained From Analysis of MGS Doppler Tracking.

    Science.gov (United States)

    Yoder, C. F.; Konopliv, A. S.; Yuan, D. N.; Standish, E. M.; Folkner, W. M.

    2002-12-01

    The solar tidal deformation of Mars, measured by its k2 potential Love number, has been obtained from analysis of MGS radio tracking. The observed k2 =0.164+-0.016 is large enough to rule out a solid iron core. The inferred core radius Rc (1600km

  17. Study of the sealing performance of tubing adapters in gas-tight deep-sea water sampler

    Directory of Open Access Journals (Sweden)

    Huang Haocai

    2014-09-01

    Full Text Available Tubing adapter is a key connection device in Gas-Tight Deep-Sea Water Sampler (GTWS. The sealing performance of the tubing adapter directly affects the GTWS’s overall gas tightness. Tubing adapters with good sealing performance can ensure the transmission of seawater samples without gas leakage and can be repeatedly used. However, the sealing performance of tubing adapters made of different materials was not studied sufficiently. With the research discussed in this paper, the materials match schemes of the tubing adapters were proposed. With non-linear finite element contact analysis and sea trials in the South China Sea, it is expected that the recommended materials match schemes not only meet the requirements of tubing adapters' sealing performance but also provide the feasible options for the following research on tubing adapters in GTWS

  18. Study of the sealing performance of tubing adapters in gas-tight deep-sea water sampler

    Directory of Open Access Journals (Sweden)

    Haocai Huang

    2014-09-01

    Full Text Available Tubing adapter is a key connection device in Gas-Tight Deep-Sea Water Sampler (GTWS. The sealing performance of the tubing adapter directly affects the GTWS's overall gas tightness. Tubing adapters with good sealing performance can ensure the transmission of seawater samples without gas leakage and can be repeatedly used. However, the sealing performance of tubing adapters made of different materials was not studied sufficiently. With the research discussed in this paper, the materials match schemes of the tubing adapters were proposed. With non-linear finite element contact analysis and sea trials in the South China Sea, it is expected that the recommended materials match schemes not only meet the requirements of tubing adapters’ sealing performance but also provide the feasible options for the following research on tubing adapters in GTWS.

  19. Main features and possibilities of the new scale module for calculation of sensitivity and uncertainty by sampling: SAMPLER; Principlaes caracteristicas y posibilidades del nuevo modulo de SCALE 6.2 para calculo de sensibilidad e incertidumbre por muestreo: SAMPLER

    Energy Technology Data Exchange (ETDEWEB)

    Mesado, C.; Miro, R.; Barrachina, T.; Verdu, G.

    2014-07-01

    Due to the importance of calculating sensitivity and uncertainty in the calculation of field engineering, and especially in the nuclear world, it has been decided to present the main features of the new module present in the new version of SCALE 6.2 (currently beta 3 version) called SAMPLER. This module allows the calculation of uncertainty in a wide range of effective sections, neutron parameters, composition and physical parameters. However, the calculation of sensitivity is not present in the beta 3 release. Even so, this module can be helpful for participants of the proposed Benchmark by Expert Group on Uncertainty Analysis in Modelling (UAM-LWR), as well as to analysts in general. (Author)

  20. Benthic organism collected using sediment sampler, BT, and bottle casts from the EASTWARD and other platforms in Georges' Bank from 10 July 1981 to 08 June 1983 (NODC Accession 8500125)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Benthic organism were collected using sediment sampler, BT, and bottle casts from the EASTWARD and other platforms in the Georges' Bank from 10 July 1981 to 08 June...

  1. Determination of C0-60 in Cobalt Slugs and Slabs and Radionuclides in Curium Sampler Slugs L-Reactor Disassembly Basin

    International Nuclear Information System (INIS)

    Casella, V.R.

    2004-01-01

    Co-60 was historically produced in the SRS reactors. Cobalt slugs were irradiated in the early 1970s. Post-production, remaining cobalt slugs (including slab form) were consolidated for storage. There are approximately nine hundred cobalt slugs currently stored awaiting final disposition. These slugs had historically incomplete documentation for activity rates; therefore, assaying was required in order to determine their activity levels. Since the gamma dose rate from these slugs is extremely high, the most cost effective way to shield a source of this magnitude from personnel and the radiation detector was to use the basin water in which the slugs are stored as the shield. A sodium iodide gamma detector was placed above a specially designed air collimator assembly, so that slug was at least eight feet from the detector and was shielded by the basin water. Using a sodium iodide detector and multichannel analyzer system and an underwater collimator assembly, Co-60 concentrations we re determined for Disassembly Basin cobalt slugs and slabs and 18 curium sampler slugs. The total activity of all of the assayed slugs summed to 31,783 curies. From the Co-60 concentrations of the curium sampler slugs, the irradiation flux was determined for the known irradiation time. The amounts of Pu-238, 239, 240, 241, 242; Am-241, 243; and Cm-242, 244 produced were then obtained based on the original amount of Pu-239 irradiated

  2. In-Process Analysis Program for the Isolock sampler at the Gunite and Associated Tanks, Oak Ridge National Laboratory, Oak Ridge, Tennessee

    International Nuclear Information System (INIS)

    1998-05-01

    The In-Process Analysis Program documents the requirements for handling, transporting, and analyzing waste slurry samples gathered by the Bristol Isolock slurry sampler from the Gunite and Associated Tanks at Oak Ridge National Laboratory in Oak Ridge, Tennessee. Composite samples will be gathered during sludge retrieval operations, labeled, transported to the appropriate laboratory, and analyzed for physical and radiological characteristics. Analysis results will be used to support occupational exposure issues, basic process control management issues, and prediction of radionuclide flow

  3. Introduction to Maxxam All-Season Passive Sampling System and Principles of Proper Use of Passive Samplers in the Field Study

    Directory of Open Access Journals (Sweden)

    Hongmao Tang

    2001-01-01

    Full Text Available Maxxam all-season passive sampling system (PASS is introduced in this paper. The PASS can be used to quantitatively and accurately monitor SO2 , NO2, O 3, and H2 S in air in all weather conditions with flexible exposure times from several hours to several months. The air pollution detection limits of PASS are very low. They can be from sub ppb to ppt levels. The principles of proper use of passive samplers in the field study are discussed by using the PASS as an example.

  4. Oxidation feature and diffusion mechanism of Zr-based metallic glasses near the glass transition point

    Science.gov (United States)

    Hu, Zheng; Lei, Xianqi; Wang, Yang; Zhang, Kun

    2018-03-01

    The oxidation behaviors of as-cast, pre-deformed, and crystallized Zr47.9Ti0.3Ni3.1Cu39.3Al9.4 metallic glasses (MGs) were studied near the glass transition point. The oxidation kinetics of the crystallized MGs followed a parabolic-rate law, and the as-cast and pre-deformed MGs exerted a typical two-stage behavior above the glass transition temperature (T g). Most interesting, pre-deformed treatment can significantly improve the oxidation rate of MGs, as the initial oxidation appeared earlier than for the as-cast MGs, and was accompanied by much thicker oxide scale. The EDS and XPS results showed that the metal Al acted as the preferred scavenger that absorbed intrinsic oxygen in the near-surface region of as-cast MGs. However, a homogeneous mixed layer without Al was observed in the pre-deformed MGs. We speculated the accelerated diffusion of other elements in the MGs was due to the local increase in the free volume and significant shear-induced dilation of the local structure. The results from this study demonstrate that MGs exhibit controllable atomic diffusion during the oxidation process, which can facilitate use in super-cooled liquid region applications.

  5. Benthic organisms collected using sediment sampler and net casts from the GUS III and EXCELLENCE in the Gulf of Mexico from 1978-05-22 to 1979-04-20 (NODC Accession 7900332)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Benthic organisms were collected using sediment sampler and net casts in the Gulf of Mexico. Data were submitted by Texas A they may have been collected by point...

  6. Time and charge calibration of Cherenkov telescope data acquired by Domino Ring Sampler 4 chips

    Energy Technology Data Exchange (ETDEWEB)

    Hoerbe, Mario; Doert, Marlene [Ruhr-Universitaet Bochum (Germany); Bruegge, Kai; Buss, Jens; Bockermann, Christian; Egorov, Alexej [TU Dortmund (Germany)

    2016-07-01

    Very-high-energy gamma-ray astronomy aims to give an insight into the most energetic phenomena in our Universe. Earthbound Cherenkov telescopes can measure Cherenkov light emitted by atmospheric particle showers which are produced by incoming cosmic particles at high energies. Current Cherenkov telescopes, e.g. operated in the FACT and the MAGIC experiments, utilize Domino Ring Sampler 4 (DRS4) chips for recording signals at high speed coming from the telescopes' cameras. DRS4 chips will also be used in the cameras of the Large-Size telescopes of the projected Cherenkov Telescope Array (CTA). We aim at developing a software solution for the calibration of DRS4 data based on the streams-framework, a software tool for streaming analysis which has been developed within the Collaborative Research Center SFB 876. The objectives and the current status of the project are presented.

  7. Engineering Task Plan for Routine Engineering Support for Core Sampler System

    International Nuclear Information System (INIS)

    BOGER, R.M.

    1999-01-01

    Routine engineering support is required during normal operation of the core sampler trucks and associated ancillary equipment. This engineering support consists of, but is not limited to, troubleshooting operation problems, correcting minor design problems, assistance with work package preparation, assistance with procurement, fabrication shop support, planning of engineering tasks and preparation of associated Engineering Task Plans (ETP) and Engineering Service Requests (ESR). This ETP is the management plan document for implementing routine engineering support. Any additional changes to the scope of this ETP shall require a Letter of Instruction from Lockheed Martin Hanford Corp (LMHC). This document will also be the Work Planning Document for Development Control (HNF 1999a). The scope of this task will be to provide routine engineering support for Characterization equipment as required to support Characterization Operations. A task by task decision will be made by management to determine which tasks will be done per this ETP and if additional ETPs and/or ESRs are required. Due to the unique nature of this task, the only identifiable deliverable is to provide support as requested. Deliverables will be recorded in a task logbook as activities are identified. ESRs will be generated for tasks that require more than 40 person hours to complete, per Characterization Engineering Desk Instructions (DI 1999a)

  8. Modeling, Stability Analysis and Active Stabilization of Multiple DC-Microgrids Clusters

    DEFF Research Database (Denmark)

    Shafiee, Qobad; Dragicevic, Tomislav; Vasquez, Juan Carlos

    2014-01-01

    ), and more especially during interconnection with other MGs, creating dc MG clusters. This paper develops a small signal model for dc MGs from the control point of view, in order to study stability analysis and investigate effects of CPLs and line impedances between the MGs on stability of these systems....... This model can be also used to synthesis and study dynamics of control loops in dc MGs and also dc MG clusters. An active stabilization method is proposed to be implemented as a dc active power filter (APF) inside the MGs in order to not only increase damping of dc MGs at the presence of CPLs but also...... to improve their stability while connecting to the other MGs. Simulation results are provided to evaluate the developed models and demonstrate the effectiveness of proposed active stabilization technique....

  9. Sadhana | Indian Academy of Sciences

    Indian Academy of Sciences (India)

    Keywords. Kriging; SPT; site investigations; land-use planning; modelling; Northern Izmir. ... Corrections were made for depth, hammer energy, rod length, sampler, borehole diameter and fines content, to the data in hand. At various depths, prepared variograms and the kriging method were used together to model the ...

  10. Overproduction of lactimidomycin by cross-overexpression of genes encoding Streptomyces antibiotic regulatory proteins.

    Science.gov (United States)

    Zhang, Bo; Yang, Dong; Yan, Yijun; Pan, Guohui; Xiang, Wensheng; Shen, Ben

    2016-03-01

    The glutarimide-containing polyketides represent a fascinating class of natural products that exhibit a multitude of biological activities. We have recently cloned and sequenced the biosynthetic gene clusters for three members of the glutarimide-containing polyketides-iso-migrastatin (iso-MGS) from Streptomyces platensis NRRL 18993, lactimidomycin (LTM) from Streptomyces amphibiosporus ATCC 53964, and cycloheximide (CHX) from Streptomyces sp. YIM56141. Comparative analysis of the three clusters identified mgsA and chxA, from the mgs and chx gene clusters, respectively, that were predicted to encode the PimR-like Streptomyces antibiotic regulatory proteins (SARPs) but failed to reveal any regulatory gene from the ltm gene cluster. Overexpression of mgsA or chxA in S. platensis NRRL 18993, Streptomyces sp. YIM56141 or SB11024, and a recombinant strain of Streptomyces coelicolor M145 carrying the intact mgs gene cluster has no significant effect on iso-MGS or CHX production, suggesting that MgsA or ChxA regulation may not be rate-limiting for iso-MGS and CHX production in these producers. In contrast, overexpression of mgsA or chxA in S. amphibiosporus ATCC 53964 resulted in a significant increase in LTM production, with LTM titer reaching 106 mg/L, which is five-fold higher than that of the wild-type strain. These results support MgsA and ChxA as members of the SARP family of positive regulators for the iso-MGS and CHX biosynthetic machinery and demonstrate the feasibility to improve glutarimide-containing polyketide production in Streptomyces strains by exploiting common regulators.

  11. Vadose Zone Monitoring of Dairy Green Water Lagoons using Soil Solution Samplers.

    Energy Technology Data Exchange (ETDEWEB)

    Brainard, James R.; Coplen, Amy K

    2005-11-01

    Over the last decade, dairy farms in New Mexico have become an important component to the economy of many rural ranching and farming communities. Dairy operations are water intensive and use groundwater that otherwise would be used for irrigation purposes. Most dairies reuse their process/green water three times and utilize lined lagoons for temporary storage of green water. Leakage of water from lagoons can pose a risk to groundwater quality. Groundwater resource protection infrastructures at dairies are regulated by the New Mexico Environment Department which currently relies on monitoring wells installed in the saturated zone for detecting leakage of waste water lagoon liners. Here we present a proposal to monitor the unsaturated zone beneath the lagoons with soil water solution samplers to provide early detection of leaking liners. Early detection of leaking liners along with rapid repair can minimize contamination of aquifers and reduce dairy liability for aquifer remediation. Additionally, acceptance of vadose zone monitoring as a NMED requirement over saturated zone monitoring would very likely significantly reduce dairy startup and expansion costs. Acknowledgment Funding for this project was provided by the Sandia National Laboratories Small Business Assistance Program

  12. Benthic organisms and marine toxic substances and pollutants collected using net and sediment samplers from the MT MITCHELL and other platforms from 22 May 1974 to 27 May 1974 (NODC Accession 7800886)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Benthic organisms and marine toxic substances and pollutants were collected using sediment sampler and net casts in the coastal waters of the East coast of US. Data...

  13. Benthic organism and marine toxic substances and pollutants collected using net and sediment sampler casts from NOAA Ship RESEARCHER in Gulf of Mexico from 1979-07-23 to 1980-12-13 (NODC Accession 8200103)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Benthic organism and marine toxic substances and pollutants were collected using net, sediment sampler, and other instruments from NOAA Ship RESEARCHER and other...

  14. Evaluation of the performance of a passive sampler in the monitoring of benzene and other volatile aromatic compounds in urban and indoor sites

    International Nuclear Information System (INIS)

    Bertoni, G.; Tappa, R.; Allegrini, I.

    1999-01-01

    Laboratory and field tests have been performed on a new passive device, properly designed for the collection of volatile organic compounds from ambient air on an active charcoal layer. Tests performed in order to determine accuracy and precision, response linearity and employment limits show that this device may be helpful in long and medium-time determinations of BTX (benzene, toluene and xylenes) in the atmosphere. The sampler is optimised for a four weeks sampling in open air [it

  15. Empirical Statistical Power for Testing Multilocus Genotypic Effects under Unbalanced Designs Using a Gibbs Sampler

    Directory of Open Access Journals (Sweden)

    Chaeyoung Lee

    2012-11-01

    Full Text Available Epistasis that may explain a large portion of the phenotypic variation for complex economic traits of animals has been ignored in many genetic association studies. A Baysian method was introduced to draw inferences about multilocus genotypic effects based on their marginal posterior distributions by a Gibbs sampler. A simulation study was conducted to provide statistical powers under various unbalanced designs by using this method. Data were simulated by combined designs of number of loci, within genotype variance, and sample size in unbalanced designs with or without null combined genotype cells. Mean empirical statistical power was estimated for testing posterior mean estimate of combined genotype effect. A practical example for obtaining empirical statistical power estimates with a given sample size was provided under unbalanced designs. The empirical statistical powers would be useful for determining an optimal design when interactive associations of multiple loci with complex phenotypes were examined.

  16. Global evaluation and calibration of a passive air sampler for gaseous mercury

    Science.gov (United States)

    McLagan, David S.; Mitchell, Carl P. J.; Steffen, Alexandra; Hung, Hayley; Shin, Cecilia; Stupple, Geoff W.; Olson, Mark L.; Luke, Winston T.; Kelley, Paul; Howard, Dean; Edwards, Grant C.; Nelson, Peter F.; Xiao, Hang; Sheu, Guey-Rong; Dreyer, Annekatrin; Huang, Haiyong; Hussain, Batual Abdul; Lei, Ying D.; Tavshunsky, Ilana; Wania, Frank

    2018-04-01

    Passive air samplers (PASs) for gaseous mercury (Hg) were deployed for time periods between 1 month and 1 year at 20 sites across the globe with continuous atmospheric Hg monitoring using active Tekran instruments. The purpose was to evaluate the accuracy of the PAS vis-à-vis the industry standard active instruments and to determine a sampling rate (SR; the volume of air stripped of gaseous Hg per unit of time) that is applicable across a wide range of conditions. The sites spanned a wide range of latitudes, altitudes, meteorological conditions, and gaseous Hg concentrations. Precision, based on 378 replicated deployments performed by numerous personnel at multiple sites, is 3.6 ± 3.0 %1, confirming the PAS's excellent reproducibility and ease of use. Using a SR previously determined at a single site, gaseous Hg concentrations derived from the globally distributed PASs deviate from Tekran-based concentrations by 14.2 ± 10 %. A recalibration using the entire new data set yields a slightly higher SR of 0.1354 ± 0.016 m3 day-1. When concentrations are derived from the PAS using this revised SR the difference between concentrations from active and passive sampling is reduced to 8.8 ± 7.5 %. At the mean gaseous Hg concentration across the study sites of 1.54 ng m-3, this represents an ability to resolve concentrations to within 0.13 ng m-3. Adjusting the sampling rate to deployment specific temperatures and wind speeds does not decrease the difference in active-passive concentration further (8.7 ± 5.7 %), but reduces its variability by leading to better agreement in Hg concentrations measured at sites with very high and very low temperatures and very high wind speeds. This value (8.7 ± 5.7 %) represents a conservative assessment of the overall uncertainty of the PAS due to inherent uncertainties of the Tekran instruments. Going forward, the recalibrated SR adjusted for temperature and wind speed should be used, especially if conditions are highly variable or

  17. Comparison of atmospheric concentrations of currently used pesticides between urban and rural areas during intensive application period in Alsace (France) by using XAD-2® based passive samplers.

    Science.gov (United States)

    Liaud, Celine; Schwartz, Jean-Jacques; Millet, Maurice

    2017-07-03

    XAD-2® passive samplers (PAS) have been exposed simultaneously for 14 days on two sites, one rural and one urban, situated in Alsace (East of France) during intensive pesticides application in agriculture (between March and September). PAS have been extracted and analyzed for current-used pesticides and lindane with an analytical method coupling accelerated solvent extraction (ASE), solid-phase microextraction (SPME) and GC/MS/MS. Results show the detection of pesticides is linked to the period of application and spatial and temporal variabilities can be observed with these PAS during the selected sampling period. The spatial and temporal variability is comparable to the one previously observed by comparing data obtained with PAS with data from Hi.-Vol. samplers in an urban area. Sampling rates were calculated for some pesticides and values are comparable to the data already available in the literature. From these sampling rates, concentrations in ng m -3 of pesticides in PAS have been calculated and are in the same order of magnitude as those obtained with Hi.Vol. sampling during the same period of time.

  18. Expression profiles of two small heat shock proteins and antioxidant enzyme activity in Mytilus galloprovincialis exposed to cadmium at environmentally relevant concentrations

    Science.gov (United States)

    You, Liping; Ning, Xuanxuan; Chen, Leilei; Zhang, Linbao; Zhao, Jianmin; Liu, Xiaoli; Wu, Huifeng

    2014-03-01

    Small heat shock proteins encompass a widespread but diverse class of proteins, which play key roles in protecting organisms from various stressors. In the present study, the full-length cDNAs of two small heat shock proteins (MgsHSP22 and MgsHSP24.1) were cloned from Mytilus galloprovincialis, which encoded peptides of 181 and 247 amino acids, respectively. Both MgsHSP22 and MgsHSP24.1 were detected in all tissues examined by real-time PCR, with the highest expression being observed in muscle and gonad tissues. The real-time PCR results revealed that Cd significantly inhibited MgsHSP22 expression at 24 h and MgsHSP24.1 at 24 and 48 h under 5 μg/L Cd 2+ exposure. MgsHSP24.1 expression was also significantly inhibited after 50 μg/L Cd2+ exposure for 48 h. With regard to antioxidant enzymes, increased GPx and CAT activity were detected under Cd2+ stress (5 and 50 μg/L), while no significant difference in SOD activity was observed throughout the experiment. Overall, both MgsHsps and antioxidant enzymes revealed their potential as Cd stress biomarkers in M. galloprovincialis.

  19. Benthic organisms and phytoplankton collected using net and sediment sampler casts from the CAPT. BRADY J and other platforms in Gulf of Mexico from 10 October 1982 to 30 November 1983 (NODC Accession 8400200)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Benthic organisms and phytoplankton were collected using sediment sampler and net casts in the Gulf of Mexico. Data were submitted by Texas A bottom depth and...

  20. Assessment of Envi-Carb™ as a passive sampler binding phase for acid herbicides without pH adjustment.

    Science.gov (United States)

    Seen, Andrew; Bizeau, Oceane; Sadler, Lachlan; Jordan, Timothy; Nichols, David

    2014-05-01

    The graphitised carbon solid phase extraction (SPE) sorbent Envi-Carb has been used to fabricate glass fibre filter- Envi-Carb "sandwich" disks for use as a passive sampler for acid herbicides. Passive sampler uptake of a suite of herbicides, including the phenoxyacetic acid herbicides 4-chloro-o-tolyloxyacetic acid (MCPA), 2,4-dichlorophenoxyacetic acid (2,4-D) and 3,6-dichloro-2-methoxybenzoic acid (Dicamba), was achieved without pH adjustment, demonstrating for the first time a suitable binding phase for passive sampling of acid herbicides at neutral pH. Passive sampling experiments with Duck River (Tasmania, Australia) water spiked at 0.5 μg L(-1) herbicide concentration over a 7 d deployment period showed that sampling rates in Duck River water decreased for seven out of eight herbicides, and in the cases of 3,6-dichloro-2-pyridinecarboxylic acid (Clopyralid) and Dicamba no accumulation of the herbicides occurred in the Envi-Carb over the deployment period. Sampling rates for 4-amino-3,5,6-trichloro-2-pyridinecarboxylic acid (Picloram), 2,4-D and MCPA decreased to approximately 30% of the sampling rates in ultrapure water, whilst sampling rates for 2-(4,6-dimethylpyrimidin-2-ylcarbamoylsulfamoyl) benzoic acid, methyl ester (Sulfometuron-methyl) and 3,5,6-Trichloro-2-pyridinyloxyacetic acid (Triclopyr) were approximately 60% of the ultrapure water sampling rate. For methyl N-(2,6-dimethylphenyl)-N-(methoxyacetyl)-D-alaninate (Metalaxyl-M) there was little variation in sampling rate between passive sampling experiments in ultrapure water and Duck River water. SPE experiments undertaken with Envi-Carb disks using ultrapure water and filtered and unfiltered Duck River water showed that not only is adsorption onto particulate matter in Duck River water responsible for a reduction in herbicide sampling rate, but interactions of herbicides with dissolved or colloidal matter (matter able to pass through a 0.2 μm membrane filter) also reduces the herbicide sampling

  1. Glycogen Synthase in Sertoli Cells: More Than Glycogenesis?

    Science.gov (United States)

    Maldonado, Rodrigo; Mancilla, Héctor; Villarroel-Espíndola, Franz; Slebe, Felipe; Slebe, Juan Carlos; Méndez, Raúl; Guinovart, Joan J; Concha, Ilona I

    2016-11-01

    Sertoli cell metabolism actively maintains the nutritional needs of germ cells. It has been described that after glucose incorporation in Sertoli cells, less than 1% is converted to glycogen suggesting low levels of glycogen synthase activity. Phosphorylation of muscle glycogen synthase (MGS) at serine 640 (pS640MGS) decreases its activity, and this form of the enzyme was discovered as a non-ribosomal protein that modulates the translation of a subset of transcripts in HeLa cells. The aim of our study was to functionally characterize MGS in cultured Sertoli cells, as well as to explore this new feature related to RNA molecules. We detected MGS in the cytoplasm of Sertoli cells as well as in the nuclei. The activity rates of the enzyme were extremely low indicating that MGS is expressed but almost inactive. Protein targeting to glycogen (PTG) overexpression was performed to activate MGS by dephosphorylation. PTG induced glycogen synthesis massively, confirming that this enzyme is present but inactive. This finding correlates with high levels of pS640MGS, which were assayed by phosphatase treatment. To explore a putative new function for MGS in Sertoli cells, we performed RNA immunoprecipitation coupled to microarray studies. The results revealed that MGS co-immunoprecipitated with the several mRNAs and also rRNAs. These findings indicate that MGS is expressed Sertoli cells but in an inactive form, and also support a possibly novel feature of this metabolic enzyme associated with RNA-related molecules. J. Cell. Biochem. 117: 2597-2607, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  2. Grading of meningeal solitary fibrous tumors/hemangiopericytomas: analysis of the prognostic value of the Marseille Grading System in a cohort of 132 patients.

    Science.gov (United States)

    Macagno, Nicolas; Vogels, Rob; Appay, Romain; Colin, Carole; Mokhtari, Karima; Küsters, Benno; Wesseling, Pieter; Figarella-Branger, Dominique; Flucke, Uta; Bouvier, Corinne

    2018-03-30

    The finding that meningeal solitary fibrous tumors (SFTs) and meningeal hemangiopericytomas (HPCs) are both characterized by NAB2-STAT6 gene fusion has pushed their inclusion in the WHO 2016 Classification of tumors of the central nervous system (CNS) as different manifestations of the same entity. Given that the clinical behavior of the CNS SFT/HPC spectrum ranges from benign to malignant, it is presently unclear whether the grading criteria are still adequate. Here, we present the results of a study that analyzed the prognostic value of an updated version of the Marseille Grading System (MGS) in a retrospectively assembled cohort of 132 primary meningeal SFTs/HPCs with nuclear overexpression of STAT6. The median patient follow-up was 64 months (range 4-274 months); 73 cases (55%) were MGS I, 50 cases (38%) MGS II and 9 cases (7%) were MGS III. Progression-free survival (PFS) and disease-specific survival (DSS) were investigated using univariate analysis: the prognostic factors for PFS included MGS, extent of surgery, radiotherapy, chemotherapy and mitotic activity ≥5/10 high-power field (HPF). Moreover, MGS, radiotherapy, mitotic activity ≥5/10 HPF, and necrosis were the prognostic factors measured for DSS. In multivariate analysis, extent of surgery, mitotic activity ≥5/10 HPF, MGS I and MGS III were the independent prognostic factors measured for PFS while necrosis, MGS III and radiotherapy were the independent prognostic factors for DSS. In conclusion, our results show that assessing the malignancy risk of SFT/HPC should not rely on one single criterion like mitotic activity. Therefore, MGS is useful as it combines the value of different criteria. In particular, the combination of a high mitotic activity and necrosis (MGS III) indicates a particularly poor prognosis. © 2018 International Society of Neuropathology.

  3. The Post-polyketide Synthase Steps in iso-Migrastatin Biosynthesis Featuring Tailoring Enzymes with Broad Substrate Specificity

    Science.gov (United States)

    Ma, Ming; Kwong, Thomas; Lim, Si-Kyu; Ju, Jianhua; Lohman, Jeremy R.; Shen, Ben

    2013-01-01

    The iso-migrastatin (iso-MGS) biosynthetic gene cluster from Streptomyces platensis NRRL 18993 consists of 11 genes, featuring an acyltransferase (AT)-less type I polyketide synthase (PKS) and three tailoring enzymes MgsIJK. Systematic inactivation of mgsIJK in S. platensis enabled us to (i) identify two nascent products (10 and 13) of the iso-MGS AT-less type I PKS, establishing an unprecedented novel feature for AT-less type I PKSs, and (ii) account for the formation of all known post-PKS biosynthetic intermediates (10-17) generated by the three tailoring enzymes MgsIJK, which possessed significant substrate promiscuities. PMID:23394593

  4. Benthic organisms data collected using sediment sampler and net casts from NOAA Ship DELAWARE II and other platforms in the New York Blight from 1957-06-19 to 1978-07-20 (NODC Accession 8000013)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Benthic organisms data were collected using sediment sampler and net casts from NOAA Ship DELAWARE II and other platforms in the New York Blight from 19 June 1957 to...

  5. Ammonia concentration modeling based on retained gas sampler data

    International Nuclear Information System (INIS)

    Terrones, G.; Palmer, B.J.; Cuta, J.M.

    1997-09-01

    The vertical ammonia concentration distributions determined by the retained gas sampler (RGS) apparatus were modeled for double-shell tanks (DSTs) AW-101, AN-103, AN-104, and AN-105 and single-shell tanks (SSTs) A-101, S-106, and U-103. One the vertical transport of ammonia in the tanks were used for the modeling. Transport in the non-convective settled solids and floating solids layers is assumed to occur primarily via some type of diffusion process, while transport in the convective liquid layers is incorporated into the model via mass transfer coefficients based on empirical correlations. Mass transfer between the top of the waste and the tank headspace and the effects of ventilation of the headspace are also included in the models. The resulting models contain a large number of parameters, but many of them can be determined from known properties of the waste configuration or can be estimated within reasonable bounds from data on the waste samples themselves. The models are used to extract effective diffusion coefficients for transport in the nonconvective layers based on the measured values of ammonia from the RGS apparatus. The modeling indicates that the higher concentrations of ammonia seen in bubbles trapped inside the waste relative to the ammonia concentrations in the tank headspace can be explained by a combination of slow transport of ammonia via diffusion in the nonconvective layers and ventilation of the tank headspace by either passive or active means. Slow transport by diffusion causes a higher concentration of ammonia to build up deep within the waste until the concentration gradients between the interior and top of the waste are sufficient to allow ammonia to escape at the same rate at which it is being generated in the waste

  6. Energy Sharing for Interconnected Microgrids with a Battery Storage System and Renewable Energy Sources Based on the Alternating Direction Method of Multipliers

    Directory of Open Access Journals (Sweden)

    Nian Liu

    2018-04-01

    Full Text Available In order to facilitate the local sharing of renewable energy, an energy sharing management method of multiple microgrids (MGs with a battery energy storage system (BESS and renewable energy sources (RESs is developed. First, a virtual entity named the energy sharing provider (ESP, which acts as an agent for MGs, is introduced to minimize the power loss cost. Second, a distributed optimal model and a two-level iterative algorithm for the MGs and ESP are proposed, which minimize the total operation cost including purchasing electricity cost, energy storage cost and power loss cost. Based on the energy sharing framework, considering the local objectives of MGs and the objective of ESP, the optimal scheduling can be achieved through the bidirectional interaction between MGs and ESP. During the optimization, the shared information between MGs and ESP is limited to expected exchange power, which protects the privacy of MGs and ESP. Finally, the effectiveness of the proposed model and algorithm in different scenarios is verified through a case study.

  7. Effect of the Cu and Ni content on the crystallization temperature and crystallization mechanism of La–Al–Cu(Ni metallic glasses

    Directory of Open Access Journals (Sweden)

    Peiyou Li

    2016-02-01

    Full Text Available The effect of the Cu and Ni content on the crystallization mechanism and the crystallization temperatures of La–Al–Cu(Ni metallic glasses (MGs was studied by differential scanning calorimetry (DSC. The experimental results have shown that the DSC curves obtained for the La–Al–Cu and La–Al–Ni MGs exhibit two and three crystallization temperatures, respectively. The crystallization temperatures of the La–Al–Cu and La–Al–Ni MGs result from the merging and splitting of thermal events related to the corresponding eutectic atomic pairs in the La72Cu28 and La81.6Al18.4 MGs, and La72Ni28 and La81.6Al18.4 MGs, respectively. In addition, Al- and Ni-containing clusters with weak or strong atomic interaction in the Al–Ni atomic pairs strongly affect the crystallization mechanism and thus the crystallization temperature of La–Al–Ni MGs. This study provides a novel understanding of the relation between the crystallization temperature and the underlying crystallization mechanisms in La–Al–Cu(Ni MGs.

  8. Global evaluation and calibration of a passive air sampler for gaseous mercury

    Directory of Open Access Journals (Sweden)

    D. S. McLagan

    2018-04-01

    Full Text Available Passive air samplers (PASs for gaseous mercury (Hg were deployed for time periods between 1 month and 1 year at 20 sites across the globe with continuous atmospheric Hg monitoring using active Tekran instruments. The purpose was to evaluate the accuracy of the PAS vis-à-vis the industry standard active instruments and to determine a sampling rate (SR; the volume of air stripped of gaseous Hg per unit of time that is applicable across a wide range of conditions. The sites spanned a wide range of latitudes, altitudes, meteorological conditions, and gaseous Hg concentrations. Precision, based on 378 replicated deployments performed by numerous personnel at multiple sites, is 3.6 ± 3.0 %1, confirming the PAS's excellent reproducibility and ease of use. Using a SR previously determined at a single site, gaseous Hg concentrations derived from the globally distributed PASs deviate from Tekran-based concentrations by 14.2 ± 10 %. A recalibration using the entire new data set yields a slightly higher SR of 0.1354 ± 0.016 m3 day−1. When concentrations are derived from the PAS using this revised SR the difference between concentrations from active and passive sampling is reduced to 8.8 ± 7.5 %. At the mean gaseous Hg concentration across the study sites of 1.54 ng m−3, this represents an ability to resolve concentrations to within 0.13 ng m−3. Adjusting the sampling rate to deployment specific temperatures and wind speeds does not decrease the difference in active–passive concentration further (8.7 ± 5.7 %, but reduces its variability by leading to better agreement in Hg concentrations measured at sites with very high and very low temperatures and very high wind speeds. This value (8.7 ± 5.7 % represents a conservative assessment of the overall uncertainty of the PAS due to inherent uncertainties of the Tekran instruments. Going forward, the recalibrated SR adjusted for temperature and wind speed

  9. A mobile sampler for mesuring the concentration of radionuclides and their physico chemical forms in natural waters

    International Nuclear Information System (INIS)

    Spezzano, P.; Giacomelli, R.; Bortoluzzi, S.; Montealto, M.; Nocente, M.

    1990-01-01

    This paper describes the realization of a sampler for concentrating radionuclides from large volume of natural waters with the purpose to determine their concentration levels and their physico-chemical forms. Sample is pumped at a flow rate of about 0.5 m 3 /h through a set of sequential filters with different pore sizes to achieve separation of 'particulate' from 'dissolved' forms. Filtered samples is then passed through sequential beds of cation and anion exchange resins and activated alumina to obtain separation of dissolved forms on the basis of their charge. Ammonium Hexacianocobalt Ferrate (NCFC is used as a selective exchanger for Cesium isotopes. Filter and exchangers are measured by computerized gamma spectrometry. Detection limits are of a few tenths of Bq per cubic meter of sample. The main results obtained during radioecological surveys are also presented

  10. Environment and Medical Sciences Division Progress Report

    International Nuclear Information System (INIS)

    Hainge, W.M.

    1980-06-01

    The 1979 annual progress report of the UKAEA Environmental and Medical Sciences Division covers both radiological and non-nuclear research programmes in the environmental and toxicological fields. The specific topics were 1) 'atmospheric pollution' which included the analysis of atmospheric trace gases by gas chromatography/mass spectrometry, the life cycle of atmospheric sulphur compounds, photochemical pollution, studies on stratospheric reactions, stratospheric ozone and the effects of pollutants, upper air sampling and monitoring gaseous atmospheric pollutants with passive samplers; 2) miscellaneous 'environmental safety projects'; 3) 'radiation physics' projects concerning a) radioactive fallout, b) studies of stable trace elements in the atmospheric environment and studies of radioactivity in the environment, c) various aspects of dosimetry research including radiation biophysics, d) personnel dosimetry, e) applied radiation spectrometry and f) data systems; 5) 'aerosol and metabolic studies' including whole body counting studies; 6) 'inhalation toxicology and radionuclide analysis' studies including actinide inhalation, cytotoxicity and fibrogenicity of non-radioactive dusts, asbestos and glass fibre research, a Qauntimet 720 image analysis service and radionuclide analysis in biological materials; and 7) 'analytical services' used in relation to 'environmental safety and chemical analysis' projects. (U.K.)

  11. Stationary Planetary Waves in the Mars Winter Atmosphere as seen by the Radio Science Experiment MaRS on Mars Express

    Science.gov (United States)

    Tellmann, Silvia; Pätzold, Martin; Häusler, Bernd; Tyler, Leonard G.; Hinson, David P.

    2015-11-01

    Stationary (Rossby) Waves are excited by the interaction of the zonally varying topography with the strong eastward winter jets. They lead to distinctive longitudinal temperature variations which contribute significantly to the asymmetry of the seasonal polar CO2 ice caps and are also important for the dust redistribution in the planetary atmosphere.Radio Science profiles from the Mars Express Radio Science Experiment MaRS at northern and southern high latitudes are used to gain insight into winter stationary wave structures on both hemispheres.Mars Global Surveyor (MGS) radio occultation measurements from the same season and year with their exceptionally good longitudinal and temporal coverage can be used to estimate the influence of transient eddies. Transient waves are especially important in the northern winter hemisphere.Wave number 2 stationary waves, driven by topography, are dominant in the northern winter latitudes while the wave number 1 wave is the most significant wave number during southern winter. The wave amplitudes peak around winter solstice on both hemispheres.Radio occultation measurements provide the unique opportunity to determine simultaneous measurements of temperature and geopotential height structures. Assuming geostrophic balance, these measurements can be used to determine meridional winds and eddy heat fluxes which provide further insight into the contribution of stationary waves to the heat exchange between the poles and the lower latitudes.

  12. Benthic organisms and marine toxic substances and pollutants collected using sediment sampler and net casts from the GUS III and EXCELLENCE in the Gulf of Mexico from 1978-05-24 to 1979-02-26 (NODC Accession 7900304)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Benthic organisms and marine toxic substances and pollutants were collected using sediment sampler and net casts in the Gulf of Mexico. Data were submitted by Texas...

  13. Evaluation of the probability distribution of intake from a single measurement on a personal air sampler

    International Nuclear Information System (INIS)

    Birchall, A.; Muirhead, C.R.; James, A.C.

    1988-01-01

    An analytical expression has been derived for the k-sum distribution, formed by summing k random variables from a lognormal population. Poisson statistics are used with this distribution to derive distribution of intake when breathing an atmosphere with a constant particle number concentration. Bayesian inference is then used to calculate the posterior probability distribution of concentrations from a given measurement. This is combined with the above intake distribution to give the probability distribution of intake resulting from a single measurement of activity made by an ideal sampler. It is shown that the probability distribution of intake is very dependent on the prior distribution used in Bayes' theorem. The usual prior assumption, that all number concentrations are equally probable, leads to an imbalance in the posterior intake distribution. This can be resolved if a new prior proportional to w -2/3 is used, where w is the expected number of particles collected. (author)

  14. Constraining the 0-20 km Vertical Profile of Water Vapor in the Martian Atmosphere with MGS-TES Limb Sounding

    Science.gov (United States)

    McConnochie, T. H.; Smith, M. D.; McDonald, G. D.

    2016-12-01

    The vertical profile of water vapor in the lower atmosphere of Mars is a crucial but poorly-measured detail of the water cycle. Most of our existing water vapor data sets (e.g. Smith, 2002, JGR 107; Smith et al., 2009, JGR 114; Maltagliati et al., 2011, Icarus 213) rely on the traditional assumption of uniform mass mixing from the surface up to a saturation level, but GCM models (Richardson et al., 2002, JGR 107; Navarro et al., 2014, JGR 119) imply that this is not the case in at least some important seasons and locations. For example at the equator during northern summer the water vapor mixing ratio in aforementioned GCMs increases upwards by a factor of two to three in the bottom scale height. This might influence the accuracy of existing precipitable water column (PWC) data sets. Even if not, the correct vertical distribution is critical for determining the extent to which high-altitude cold trapping interferes with inter-hemispheric transport, and its details in the lowest scale heights will be a critical test of the accuracy of modeled water vapor transport. Meanwhile attempts to understand apparent interactions of water vapor with surface soils (e.g. Ojha et al. 2015, Nature Geoscience 8; Savijärvi et al., 2016, Icarus 265) need an estimate for the amount of water vapor in the boundary layer, and existing PWC data sets can't provide this unless the lower atmospheric vertical distribution is known or constrained. Maltagliati et al. (2013, Icarus 223) have obtained vertical profiles of water vapor at higher altitudes with SPICAM on Mars Express, but these are commonly limited to altitudes greater 20 km and they never extend below 10 km. We have previously used Mars Global Surveyor (MGS) Thermal Emission Spectrometer (TES) limb-sounding to measure the vertical profile of water vapor (e.g. McConnochie and Smith, 2009, Fall AGU #P54B-06), but these preliminary results were clearly not quantitatively accurate in the lower atmosphere. We will present improved TES

  15. Comparison of dialysis membrane diffusion samplers and two purging methods in bedrock wells

    Science.gov (United States)

    Imbrigiotta, T.E.; Ehlke, T.A.; Lacombe, P.J.; Dale, J.M.; ,

    2002-01-01

    Collection of ground-water samples from bedrock wells using low-flow purging techniques is problematic because of the random spacing, variable hydraulic conductivity, and variable contamination of contributing fractures in each well's open interval. To test alternatives to this purging method, a field comparison of three ground-water-sampling techniques was conducted on wells in fractured bedrock at a site contaminated primarily with volatile organic compounds. Constituent concentrations in samples collected with a diffusion sampler constructed from dialysis membrane material were compared to those in samples collected from the same wells with a standard low-flow purging technique and a hybrid (high-flow/low-flow) purging technique. Concentrations of trichloroethene, cis-1,2-dichloroethene, vinyl chloride, calcium, chloride, and alkalinity agreed well among samples collected with all three techniques in 9 of the 10 wells tested. Iron concentrations varied more than those of the other parameters, but their pattern of variation was not consistent. Overall, the results of nonparametric analysis of variance testing on the nine wells sampled twice showed no statistically significant difference at the 95-percent confidence level among the concentrations of volatile organic compounds or inorganic constituents recovered by use of any of the three sampling techniques.

  16. Passive sampling of selected pesticides in aquatic environment using polar organic chemical integrative samplers.

    Science.gov (United States)

    Thomatou, Alphanna-Akrivi; Zacharias, Ierotheos; Hela, Dimitra; Konstantinou, Ioannis

    2011-08-01

    Polar chemical integrative samplers (POCIS) were examined for their sampling efficiency of 12 pesticides and one metabolite commonly detected in surface waters. Laboratory-based calibration experiments of POCISs were conducted. The determined passive sampling rates were applied for the monitoring of pesticides levels in Lake Amvrakia, Western Greece. Spot sampling was also performed for comparison purposes. Calibration experiments were performed on the basis of static renewal exposure of POCIS under stirred conditions for different time periods of up to 28 days. The analytical procedures were based on the coupling of POCIS and solid phase extraction by Oasis HLB cartridges with gas chromatography-mass spectrometry. The recovery of the target pesticides from the POCIS was generally >79% with relative standard deviation (RSD) monitoring campaign using both passive and spot sampling whereas higher concentrations were measured by spot sampling in most cases. Passive sampling by POCIS provides a useful tool for the monitoring of pesticides in aquatic systems since integrative sampling at rates sufficient for analytical quantitation of ambient levels was observed. Calibration data are in demand for a greater number of compounds in order to extend the use in environmental monitoring.

  17. Scientists: Get Involved in Planetary Science Education and Public Outreach! Here’s How!

    Science.gov (United States)

    Buxner, Sanlyn; Dalton, H.; Shipp, S.; CoBabe-Ammann, E.; Scalice, D.; Bleacher, L.; Wessen, A.

    2013-10-01

    The Planetary Science Education and Public Outreach (E/PO) Forum is a team of educators, scientists, and outreach professionals funded by NASA’s Science Mission Directorate (SMD) that supports SMD scientists currently involved in E/PO - or interested in becoming involved in E/PO efforts - to find ways to do so through a variety of avenues. There are many current and future opportunities and resources for scientists to become engaged in E/PO. The Forum provides tools for responding to NASA SMD E/PO funding opportunities (webinars and online proposal guides), a one-page Tips and Tricks guide for scientists to engage in education and public outreach, and a sampler of activities organized by thematic topic and NASA’s Big Questions in planetary science. Scientists can also locate resources for interacting with diverse audiences through a number of online clearinghouses, including: NASA Wavelength, a digital collection of peer-reviewed Earth and space science resources for educators of all levels (http://nasawavelength.org); the Year of the Solar System website (http://solarsystem.nasa.gov/yss), a presentation of thematic resources that includes background information, missions, the latest in planetary science news, and educational products, for use in the classroom and out, for teaching about the solar system organized by topic - volcanism, ice, astrobiology, etc.; and EarthSpace (http://www.lpi.usra.edu/earthspace), a community website where faculty can find and share resources and information about teaching Earth and space sciences in the undergraduate classroom, including class materials, news, funding opportunities, and the latest education research. Also recently developed, the NASA SMD Scientist Speaker’s Bureau (http://www.lpi.usra.edu/education/speaker) offers an online portal to connect scientists interested in getting involved in E/PO projects - giving public talks, classroom visits, and virtual connections - with audiences. Learn more about the

  18. The kinetic origin of delayed yielding in metallic glasses

    International Nuclear Information System (INIS)

    Ye, Y. F.; Liu, X. D.; Wang, S.; Liu, C. T.; Yang, Y.; Fan, J.

    2016-01-01

    Recent experiments showed that irreversible structural change or plasticity could occur in metallic glasses (MGs) even within the apparent elastic limit after a sufficiently long waiting time. To explain this phenomenon, a stochastic shear transformation model is developed based on a unified rate theory to predict delayed yielding in MGs, which is validated afterwards through extensive atomistic simulations carried out on different MGs. On a fundamental level, an analytic framework is established in this work that links time, stress, and temperature altogether into a general yielding criterion for MGs.

  19. The kinetic origin of delayed yielding in metallic glasses

    Energy Technology Data Exchange (ETDEWEB)

    Ye, Y. F.; Liu, X. D.; Wang, S.; Liu, C. T.; Yang, Y., E-mail: yonyang@cityu.edu.hk [Department of Mechanical and Biomedical Engineering, Centre for Advanced Structural Materials, City University of Hong Kong, Tat Chee Avenue, Kowloon Tong, Kowloon, Hong Kong (China); Fan, J. [Department of Applied Physics and Materials Science, City University of Hong Kong, Tat Chee Avenue, Kowloon Tong, Kowloon, Hong Kong (China)

    2016-06-20

    Recent experiments showed that irreversible structural change or plasticity could occur in metallic glasses (MGs) even within the apparent elastic limit after a sufficiently long waiting time. To explain this phenomenon, a stochastic shear transformation model is developed based on a unified rate theory to predict delayed yielding in MGs, which is validated afterwards through extensive atomistic simulations carried out on different MGs. On a fundamental level, an analytic framework is established in this work that links time, stress, and temperature altogether into a general yielding criterion for MGs.

  20. Plasticity of ductile metallic glasses: a self-organized critical state.

    Science.gov (United States)

    Sun, B A; Yu, H B; Jiao, W; Bai, H Y; Zhao, D Q; Wang, W H

    2010-07-16

    We report a close correlation between the dynamic behavior of serrated flow and the plasticity in metallic glasses (MGs) and show that the plastic deformation of ductile MGs can evolve into a self-organized critical state characterized by the power-law distribution of shear avalanches. A stick-slip model considering the interaction of multiple shear bands is presented to reveal complex scale-free intermittent shear-band motions in ductile MGs and quantitatively reproduce the experimental observations. Our studies have implications for understanding the precise plastic deformation mechanism of MGs.

  1. Atomistic origin of size effects in fatigue behavior of metallic glasses

    Science.gov (United States)

    Sha, Zhendong; Wong, Wei Hin; Pei, Qingxiang; Branicio, Paulo Sergio; Liu, Zishun; Wang, Tiejun; Guo, Tianfu; Gao, Huajian

    2017-07-01

    While many experiments and simulations on metallic glasses (MGs) have focused on their tensile ductility under monotonic loading, the fatigue mechanisms of MGs under cyclic loading still remain largely elusive. Here we perform molecular dynamics (MD) and finite element simulations of tension-compression fatigue tests in MGs to elucidate their fatigue mechanisms with focus on the sample size effect. Shear band (SB) thickening is found to be the inherent fatigue mechanism for nanoscale MGs. The difference in fatigue mechanisms between macroscopic and nanoscale MGs originates from whether the SB forms partially or fully through the cross-section of the specimen. Furthermore, a qualitative investigation of the sample size effect suggests that small sample size increases the fatigue life while large sample size promotes cyclic softening and necking. Our observations on the size-dependent fatigue behavior can be rationalized by the Gurson model and the concept of surface tension of the nanovoids. The present study sheds light on the fatigue mechanisms of MGs and can be useful in interpreting previous experimental results.

  2. Measurements of ambient radioxenon levels using the automated radioxenon sampler/analyzer (ARSA)

    International Nuclear Information System (INIS)

    McIntyre, J.I.; Abel, K.H.; Bowyer, T.W.; Hayes, J.C.; Heimbigner, T.R.; Panisko, M.E.; Reeder, P.L.; Thompson, R.C.

    2001-01-01

    The Pacific Northwest National Laboratory has developed an Automated Radioxenon Sampler/Analyzer (ARSA) in support of the Comprehensive Nuclear-Test-Ban-Treaty (CTBT) to measure four radioxenon isotopes: 131m Xe, 133m Xe, 133g Xe, and 135g Xe. This system uses a beta-gamma coincidence counting detector to produce two-dimensional plots of gamma-energy versus beta-energy. Betas and conversion electrons (CE) are detected in a cylindrical plastic scintillation cell and gamma and X-rays are detected in a surrounding NaI(Tl) scintillation detector. The ARSA has been field tested at several locations to measure the radioxenon concentrations. Most recently it has been deployed at the Institut fuer Atmosphaerische Radioaktivitaet in Freiburg, Germany. During the first 4 months of 2000 the measured 133 Xe concentrations have varied between 0.0 ± 0.1 and 110 ± 10 mBq/m 3 air. The longer lived 131m Xe (T 1/2 = 11.9 d) and short lived 135 Xe (T 1/2 = 9.1 h) have also been detected in small quantities, while 133m Xe concentrations have been consistent with zero. Minimum detectable concentration (MDC) calculations for 133g Xe fell well below the 1 mBq per standard-cubic-meter of air requirement adopted by the CTBT Preparatory Commission. A description of the radioxenon detector, the concentration and MDC calculations and preliminary results of the field test in Germany are presented. (author)

  3. Probabilistic Magnetotelluric Inversion with Adaptive Regularisation Using the No-U-Turns Sampler

    Science.gov (United States)

    Conway, Dennis; Simpson, Janelle; Didana, Yohannes; Rugari, Joseph; Heinson, Graham

    2018-04-01

    We present the first inversion of magnetotelluric (MT) data using a Hamiltonian Monte Carlo algorithm. The inversion of MT data is an underdetermined problem which leads to an ensemble of feasible models for a given dataset. A standard approach in MT inversion is to perform a deterministic search for the single solution which is maximally smooth for a given data-fit threshold. An alternative approach is to use Markov Chain Monte Carlo (MCMC) methods, which have been used in MT inversion to explore the entire solution space and produce a suite of likely models. This approach has the advantage of assigning confidence to resistivity models, leading to better geological interpretations. Recent advances in MCMC techniques include the No-U-Turns Sampler (NUTS), an efficient and rapidly converging method which is based on Hamiltonian Monte Carlo. We have implemented a 1D MT inversion which uses the NUTS algorithm. Our model includes a fixed number of layers of variable thickness and resistivity, as well as probabilistic smoothing constraints which allow sharp and smooth transitions. We present the results of a synthetic study and show the accuracy of the technique, as well as the fast convergence, independence of starting models, and sampling efficiency. Finally, we test our technique on MT data collected from a site in Boulia, Queensland, Australia to show its utility in geological interpretation and ability to provide probabilistic estimates of features such as depth to basement.

  4. Study on air pollution monitoring in Korea using low volume air sampler by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Yong Sam Chung; Jong Hwa Moon, Young Ju Chung; Seung Yeon Cho; Sang Hun Kang

    1999-01-01

    The aim of this research was to enhance the use of nuclear analytical techniques for air pollution studies and to study the feasibility of the use of instrumental neutron activation analysis (INAA) as a routine monitoring tool to reveal environmental pollution sources. For the collection of air particulate samples, the Gent stacked filter unit, low volume sampler with Nucleopore membrane filters were used. Trace elements in samples collected at two suburban residential sites, Taejon and Wonju city in the Republic of Korea, were analyzed by INAA. Variations of the elemental concentrations were measured monthly and the enrichment factors were calculated for the fine (< 2 μm EAD) and coarse size (2-10 μm EAD) fractions. The analytical data were treated statistically to estimate the relationship between the two variables, the concentrations of elements and the total suspended particulate matter. The results were used to describe the emission source and their correlation. (author)

  5. A recirculation aerosol wind tunnel for evaluating aerosol samplers and measuring particle penetration through protective clothing materials.

    Science.gov (United States)

    Jaques, Peter A; Hsiao, Ta-Chih; Gao, Pengfei

    2011-08-01

    A recirculation aerosol wind tunnel was designed to maintain a uniform airflow and stable aerosol size distribution for evaluating aerosol sampler performance and determining particle penetration through protective clothing materials. The oval-shaped wind tunnel was designed to be small enough to fit onto a lab bench, have optimized dimensions for uniformity in wind speed and particle size distributions, sufficient mixing for even distribution of particles, and minimum particle losses. Performance evaluation demonstrates a relatively high level of spatial uniformity, with a coefficient of variation of 1.5-6.2% for wind velocities between 0.4 and 2.8 m s(-1) and, in this range, 0.8-8.5% for particles between 50 and 450 nm. Aerosol concentration stabilized within the first 5-20 min with, approximately, a count median diameter of 135 nm and geometric standard deviation of 2.20. Negligible agglomerate growth and particle loss are suggested. The recirculation design appears to result in unique features as needed for our research.

  6. Hierarchical Control for Multiple DC-Microgrids Clusters

    DEFF Research Database (Denmark)

    Shafiee, Qobad; Dragicevic, Tomislav; Vasquez, Juan Carlos

    2014-01-01

    DC microgrids (MGs) have gained research interest during the recent years because of many potential advantages as compared to the ac system. To ensure reliable operation of a low-voltage dc MG as well as its intelligent operation with the other DC MGs, a hierarchical control is proposed in this p......DC microgrids (MGs) have gained research interest during the recent years because of many potential advantages as compared to the ac system. To ensure reliable operation of a low-voltage dc MG as well as its intelligent operation with the other DC MGs, a hierarchical control is proposed...

  7. Low-Voltage Ride-Through Operation of Power Converters in Grid-Interactive Microgrids by Using Negative-Sequence Droop Control

    DEFF Research Database (Denmark)

    Zhao, Xin; Guerrero, Josep M.; Savaghebi, Mehdi

    2017-01-01

    of the utility grid during grid faults. In this paper, a LVRT control strategy based on positive/negative sequence droop control is proposed for grid-interactive MGs to ride-through voltage sags with not only inductive/resistive, but also complex line impedance. By using the proposed control strategy, MGs can......Due to the increasing penetration level of microgrids (MGs), it becomes a critical issue for MGs to help sustaining power system stability. Therefore, ancillary services, such as the low-voltage ride-through (LVRT) capability should be incorporated in MGs in order to guarantee stable operation...... support the grid voltage, make profits, and also ride-through the voltage dip during the whole fault period. A two layer hierarchical control strategy is proposed in this paper. The primary controller consists of voltage and current inner loops, a conventional droop control and a virtual impedance loop...

  8. Surface Chemistry Interactions of Cationorm with Films by Human Meibum and Tear Film Compounds

    Directory of Open Access Journals (Sweden)

    Georgi As. Georgiev

    2017-07-01

    Full Text Available Cationorm® (CN cationic nanoemulsion was demonstrated to enhance tear film (TF stability in vivo possibly via effects on tear film lipid layer (TFLL. Therefore the interactions of CN with human meibum (MGS and TFLL in vitro and in vivo deserve special study. MGS and CN were spread at the air/water interface of a Langmuir surface balance to ensure a range of MGS/CN oil phase ratios: 20/1, 10/1, 5/1, 3/1, 2/1 and 1/1. The films capability to reorganize during dynamic area changes was evaluated via the surface pressure-area compression isotherms and step/relaxation dilatational rheology studies. Films structure was monitored with Brewster angle microscopy. CN/TFLL interactions at the ocular surface were monitored with non-contact specular microscopy. The in vitro studies of MGS/CN layers showed that (i CN inclusion (at fixed MGS content increased film elasticity and thickness and that (ii CN can compensate for moderate meibum deficiency in MGS/CN films. In vivo CN mixed with TFLL in a manner similar to CN/MGS interactions in vitro, and resulted in enhanced thickness of TFLL. In vitro and in vivo data complement each other and facilitated the study of the composition-structure-function relationship that determines the impact of cationic nanoemulsions on TF.

  9. Field Comparisons of the Elwha Bedload Sampler and an Acoustic Gravel-transport Sensor: Middle Fork of the Piedra River, Colorado, USA

    Science.gov (United States)

    Downing, J.; Ryan, S. E.

    2001-12-01

    Ten simultaneous bedload measurements were made with an Elhwa sampler and an acoustic-gravel-transport sensor (GTS) on the Middle Fork of the Piedra River in southwestern Colorado near the end of the spring freshet in water year 2001. The purpose was to compare bedload samples with acoustic measurements acquired under field conditions. Upstream of the measurement site, the river drains 86 km2 of andesite, ash flows, tuffs, and breccias in the San Juan Mountains, contributing a relatively high sediment load to the river system. The channel transitions from step-pools at high elevations to a plane bed with a slope of 0.018 in the study reach. Channel width, mean depth and bank-full velocity at the site are: 13.6 m, 0.52, and 1.5 m s-1. The D50 of the riverbed surface is 0.08 m which is 6 to 40 times larger than the D50s of the bedload samples. D16 and D84 of the bed = 0.02 and 0.21 m respectively. Water discharges from 7.3 to 9.3 m3 s-1 transported about 0.01 kg of gravel m-1 s-1 in the channel. Transport of coarse gravel (8-64 mm) ranged from 0.00063 to 0.024 kg m-1 s-1. The Elwha sampler is a portable, pressure-differential trap with a 0.2 m wide by 0.1 m high opening. The acoustic sensor is a 0.025-m wide by 0.1 m high strip of PVDF piezoelectric film connected to a signal processor and bonded to an aluminum pressure plate. When the plate is struck by stones, the GTS produces signal peaks with areas that are accurate measures of stone momentum. The GTS was calibrated with steels balls dropped on the pressure plate in still water to develop a curve of ball momentum as a function of peak areas. Based on these calibrations, the standard error of the GTS momentum estimates is 0.0017 kg m s-1. Five transects with 30 verticals, each occupied for 60 s, were completed with the sampler and GTS separated by < 1 m. Five additional verticals were occupied for about 1800 s each with the instruments separated by < 0.5 m. The trapped material was sieved and weighed and the water

  10. Intersampler field comparison of Respicon(R), IOM, and closed-face 25-mm personal aerosol samplers during primary production of aluminium.

    Science.gov (United States)

    Skaugset, Nils Petter; Ellingsen, Dag G; Notø, Hilde; Jordbekken, Lars; Thomassen, Yngvar

    2013-10-01

    Intersampler field comparison of Respicon(®), 25-mm closed-face 'total dust' cassette (CFC), and IOM inhalable aerosol sampler was conducted in pot rooms at seven aluminium smelters. The aerosol mass and water-soluble fluoride were selected as airborne contaminants for the comparisons. The aerosol masses of 889 sample pairs of IOM and Respicon(®) inhalable aerosol sub-fraction, 165 of IOM and 25-mm CFC, and 194 of CFC and Respicon(®) thoracic aerosol sub-fraction were compared. The number of sample pairs for the comparison of water-soluble fluoride was 906, 170, and 195, respectively. The geometric mean aerosol mass collected with the inhalable Respicon(®) was 2.91 mg m(-3) compared with 3.38 mg m(-3) with the IOM. The overall ratio between IOM and Respicon(®) inhalable sub-fraction was 1.16 [95% confidence interval (CI) = 1.11-1.21] for aerosol mass and 1.13 (95% CI = 1.08-1.18) for water-soluble fluoride. The results indicate that Respicon(®) undersampled the aerosol mass and water-soluble fluoride in the inhalable sub-fraction compared with the IOM. The results indicated undersampling of the Respicon(®) at mass concentrations higher than 1.35 mg m(-3) and oversampling at lower mass concentrations. The overall ratio between aerosol mass collected with IOM and CFC was 4.19 (95% CI = 3.79-4.64) and 1.61 (95% CI = 1.51-1.72) for water-soluble fluoride. Thus, for this industry, a correction factor of 4.2 is suggested for the conversion of CFC to inhalable aerosol masses and a conversion factor of 1.6 for water-soluble fluoride if wall deposits in the CFC are included. CFC and thoracic Respicon(®) collected similar aerosol masses (ratio = 1.04; 95% CI = 0.97-1.12), whereas the ratio was 1.19 (95% CI = 1.11-1.28) for water-soluble fluoride. The variability of the exposure is substantial; thus, large data sets are required in sampler performance field comparisons.

  11. The Age-Related Macular Degeneration Complex: Linking Epidemiology and Histopathology Using the Minnesota Grading System (The Inaugural Frederick C. Blodi Lecture).

    Science.gov (United States)

    Olsen, Timothy W; Bottini, Alexander R; Mendoza, Pia; Grossniklausk, Hans E

    2015-09-01

    To describe the histopathologic findings of the four stages of age-related macular degeneration (AMD) as defined by the Age-Related Eye Disease Study (AREDS) using the Minnesota grading system (MGS). There are no animal models for AMD. Eye banks enable access to human tissue with AMD. The level of AMD (grades 1 through 4) as defined by AREDS is determined ex vivo using the MGS. The AREDS has the largest collection to date of prospectively gathered data on the natural history of AMD. Since the MGS uses the same clinical criteria as AREDS, the addition of histopathologic findings of graded tissue confirms important pathophysiology at each stage of AMD. Four eye bank eyes were graded according to the MGS. Only the right eyes were dissected for phenotype grading. The fellow (left) eyes were fixed for histopathologic study. The eyes were serially sectioned (7 μm) through the macula. Individual slides were examined, and a two-dimensional reconstruction of the topography of the macula was created for each donor. Selected, unstained slides were used for immunohistochemical staining. In one donor, portions of tissue were obtained for transmission electron microscopic (TEM) processing. Donor 1 had a rare hard, nodular druse (MGS1). Donor 2 had intermediate confluent drusen (MGS2). Donor 3 had numerous intermediate drusen (MGS3) in the right eye. Histopathology of the fellow left showed basal laminar deposits (BLamD), soft drusen, and an area of occult choroidal neovascularization underlying the retinal pigment epithelium (RPE) with endothelial cells (CD31-positive). Donor 4 also had MGS 3 along with reticular pseudodrusen (RPD). Histologic and TEM examination demonstrated diffuse BLamD, thickening of Bruch's membrane, hard drusen, and focal nodules underlying the RPE that corresponded to the RPD. EM examination demonstrated both BLamD and electron-dense material located just external to the elastic layer of Bruch's membrane. Eye bank eyes graded using the MGS serve as an

  12. The Nine-Step Minnesota Grading System for Eyebank Eyes With Age Related Macular Degeneration: A Systematic Approach to Study Disease Stages.

    Science.gov (United States)

    Olsen, Timothy W; Liao, Albert; Robinson, Hershonna S; Palejwala, Neal V; Sprehe, Nicholas

    2017-10-01

    To refine the Minnesota Grading System (MGS) using definitions from the Age-Related Eye Disease Studies (AREDS) into a nine-step grading scale (MGS-9). A nine-step grading scale descriptive analysis using three key phenotypic features (total drusen area, increased, and decreased pigmentation) of human eyebank eyes that were graded according to definitions from the AREDS criteria in order to harmonize studies of disease progression for research involving human tissue. From 2005 through February 2017, we have analyzed 1159 human eyes, procured from two eyebanks. Each macula was imaged using high-resolution, stereoscopic color fundus photography with both direct- and transillumination. Fundus images were digitally overlaid with a grading template and triangulated for foveal centration. We documented and stratified risk for each globe by applying the AREDS nine-step grading scale to the key clinical features from the MGS-9. We found a good distribution within the MGS categories (1-9) with few level eight globes. Eyes were processed within 12.1 ± 6.3, hours from the time of death through imaging, dissection, and freezing or fixation. Applying the MGS-9 to 331 pairs (662 eyes were simultaneously graded), 84% were within one-grading step and 93% within two steps of the fellow eye. We also document reticular pseudodrusen, basal laminar drusen, and pattern dystrophy. The MGS nine-step grading scale enables researchers using human tissue to refine the risk assessment of donor tissue. This analysis will harmonize results among researchers when grading human tissue using MGS criteria. Most importantly, the MGS-9 links directly to the known risk for progression from the AREDS.

  13. A Critical Review on Metallic Glasses as Structural Materials for Cardiovascular Stent Applications.

    Science.gov (United States)

    Jafary-Zadeh, Mehdi; Praveen Kumar, Gideon; Branicio, Paulo Sergio; Seifi, Mohsen; Lewandowski, John J; Cui, Fangsen

    2018-02-27

    Functional and mechanical properties of novel biomaterials must be carefully evaluated to guarantee long-term biocompatibility and structural integrity of implantable medical devices. Owing to the combination of metallic bonding and amorphous structure, metallic glasses (MGs) exhibit extraordinary properties superior to conventional crystalline metallic alloys, placing them at the frontier of biomaterials research. MGs have potential to improve corrosion resistance, biocompatibility, strength, and longevity of biomedical implants, and hence are promising materials for cardiovascular stent applications. Nevertheless, while functional properties and biocompatibility of MGs have been widely investigated and validated, a solid understanding of their mechanical performance during different stages in stent applications is still scarce. In this review, we provide a brief, yet comprehensive account on the general aspects of MGs regarding their formation, processing, structure, mechanical, and chemical properties. More specifically, we focus on the additive manufacturing (AM) of MGs, their outstanding high strength and resilience, and their fatigue properties. The interconnection between processing, structure and mechanical behaviour of MGs is highlighted. We further review the main categories of cardiovascular stents, the required mechanical properties of each category, and the conventional materials have been using to address these requirements. Then, we bridge between the mechanical requirements of stents, structural properties of MGs, and the corresponding stent design caveats. In particular, we discuss our recent findings on the feasibility of using MGs in self-expandable stents where our results show that a metallic glass based aortic stent can be crimped without mechanical failure. We further justify the safe deployment of this stent in human descending aorta. It is our intent with this review to inspire biodevice developers toward the realization of MG-based stents.

  14. A Critical Review on Metallic Glasses as Structural Materials for Cardiovascular Stent Applications

    Directory of Open Access Journals (Sweden)

    Mehdi Jafary-Zadeh

    2018-02-01

    Full Text Available Functional and mechanical properties of novel biomaterials must be carefully evaluated to guarantee long-term biocompatibility and structural integrity of implantable medical devices. Owing to the combination of metallic bonding and amorphous structure, metallic glasses (MGs exhibit extraordinary properties superior to conventional crystalline metallic alloys, placing them at the frontier of biomaterials research. MGs have potential to improve corrosion resistance, biocompatibility, strength, and longevity of biomedical implants, and hence are promising materials for cardiovascular stent applications. Nevertheless, while functional properties and biocompatibility of MGs have been widely investigated and validated, a solid understanding of their mechanical performance during different stages in stent applications is still scarce. In this review, we provide a brief, yet comprehensive account on the general aspects of MGs regarding their formation, processing, structure, mechanical, and chemical properties. More specifically, we focus on the additive manufacturing (AM of MGs, their outstanding high strength and resilience, and their fatigue properties. The interconnection between processing, structure and mechanical behaviour of MGs is highlighted. We further review the main categories of cardiovascular stents, the required mechanical properties of each category, and the conventional materials have been using to address these requirements. Then, we bridge between the mechanical requirements of stents, structural properties of MGs, and the corresponding stent design caveats. In particular, we discuss our recent findings on the feasibility of using MGs in self-expandable stents where our results show that a metallic glass based aortic stent can be crimped without mechanical failure. We further justify the safe deployment of this stent in human descending aorta. It is our intent with this review to inspire biodevice developers toward the realization

  15. A Critical Review on Metallic Glasses as Structural Materials for Cardiovascular Stent Applications

    Science.gov (United States)

    Jafary-Zadeh, Mehdi; Praveen Kumar, Gideon

    2018-01-01

    Functional and mechanical properties of novel biomaterials must be carefully evaluated to guarantee long-term biocompatibility and structural integrity of implantable medical devices. Owing to the combination of metallic bonding and amorphous structure, metallic glasses (MGs) exhibit extraordinary properties superior to conventional crystalline metallic alloys, placing them at the frontier of biomaterials research. MGs have potential to improve corrosion resistance, biocompatibility, strength, and longevity of biomedical implants, and hence are promising materials for cardiovascular stent applications. Nevertheless, while functional properties and biocompatibility of MGs have been widely investigated and validated, a solid understanding of their mechanical performance during different stages in stent applications is still scarce. In this review, we provide a brief, yet comprehensive account on the general aspects of MGs regarding their formation, processing, structure, mechanical, and chemical properties. More specifically, we focus on the additive manufacturing (AM) of MGs, their outstanding high strength and resilience, and their fatigue properties. The interconnection between processing, structure and mechanical behaviour of MGs is highlighted. We further review the main categories of cardiovascular stents, the required mechanical properties of each category, and the conventional materials have been using to address these requirements. Then, we bridge between the mechanical requirements of stents, structural properties of MGs, and the corresponding stent design caveats. In particular, we discuss our recent findings on the feasibility of using MGs in self-expandable stents where our results show that a metallic glass based aortic stent can be crimped without mechanical failure. We further justify the safe deployment of this stent in human descending aorta. It is our intent with this review to inspire biodevice developers toward the realization of MG-based stents

  16. Study of particulate matter from Primary/Secondary Marine Aerosol and anthropogenic sources collected by a self-made passive sampler for the evaluation of the dry deposition impact on built heritage.

    Science.gov (United States)

    Morillas, Héctor; Maguregui, Maite; García-Florentino, Cristina; Marcaida, Iker; Madariaga, Juan Manuel

    2016-04-15

    Dry deposition is one of the most dangerous processes that can take place in the environment where the compounds that are suspended in the atmosphere can react directly on different surrounding materials, promoting decay processes. Usually this process is related with industrial/urban fog and/or marine aerosol in the coastal areas. Particularly, marine aerosol transports different types of salts which can be deposited on building materials and by dry deposition promotes different decay pathways. A new analytical methodology based on the combined use of Raman Spectroscopy and SEM-EDS (point-by-point and imaging) was applied. For that purpose, firstly evaporated seawater (presence of Primary Marine Aerosol (PMA)) was analyzed. After that, using a self-made passive sampler (SMPS), different suspended particles coming from marine aerosol (transformed particles in the atmosphere (Secondary Marine Aerosol (SMA)) and metallic airborne particulate matter coming from anthropogenic sources, were analyzed. Finally in order to observe if SMA and metallic particles identified in the SMPS can be deposited on a building, sandstone samples from La Galea Fortress (Getxo, north of Spain) located in front of the sea and in the place where the passive sampler was mounted were analyzed. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. A miniature bird-borne passive air sampler for monitoring halogenated flame retardants.

    Science.gov (United States)

    Sorais, Manon; Rezaei, Ali; Okeme, Joseph O; Diamond, Miriam L; Izquierdo, Ricardo; Giroux, Jean-François; Verreault, Jonathan

    2017-12-01

    Birds have been used intensively as biomonitors of halogenated flame retardants (HFRs), and several studies have reported elevated tissue concentrations and inter-individual variability for these contaminants. While diet is known to be an important exposure pathway for HFRs in birds, it has been suggested that exposure through air may represent an underestimated source of HFRs for certain species. However, a method was not available for measuring the atmospheric exposure of individual birds to HFRs or other semi-volatile contaminants. The goal of this study was to develop a bird-borne passive air sampler (PAS) enabling the determination of individual atmospheric exposure to gas- and particle-phase HFRs using the ring-billed gull (Larus delawarensis) nesting in the Montreal area (QC, Canada). The new miniaturized elliptical-shaped PAS (mean weight: 2.72g) was tested using two sorbent types during three exposure periods (one, two and three weeks). Results showed that PAS using polyurethane foam (PUF) combined with a glass fiber filter collected all major polybrominated diphenyl ethers (PBDEs) and exhibited better performance for collecting highly hydrophobic DecaBDE mixture congeners compared to the PAS using polydimethylsiloxane (PDMS). Emerging HFRs including hexabromobenzene, Dechlorane 604 Component B, and Dechlorane plus (DP) isomers also were sampled by the PUF-based PAS. Sampling rates for most HFRs were comparable between the three exposure periods. This novel bird-borne PAS provides valuable information on the non-dietary exposure of free-ranging birds to HFRs. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Methylglyoxal synthase regulates cell elongation via alterations of cellular methylglyoxal and spermidine content in Bacillus subtilis.

    Science.gov (United States)

    Shin, Sang-Min; Song, Sung-Hyun; Lee, Jin-Woo; Kwak, Min-Kyu; Kang, Sa-Ouk

    2017-10-01

    Methylglyoxal regulates cell division and differentiation through its interaction with polyamines. Loss of their biosynthesizing enzyme causes physiological impairment and cell elongation in eukaryotes. However, the reciprocal effects of methylglyoxal and polyamine production and its regulatory metabolic switches on morphological changes in prokaryotes have not been addressed. Here, Bacillus subtilis methylglyoxal synthase (mgsA) and polyamine biosynthesizing genes encoding arginine decarboxylase (SpeA), agmatinase (SpeB), and spermidine synthase (SpeE), were disrupted or overexpressed. Treatment of 0.2mM methylglyoxal and 1mM spermidine led to the elongation and shortening of B. subtilis wild-type cells to 12.38±3.21μm (P<0.05) and 3.24±0.73μm (P<0.01), respectively, compared to untreated cells (5.72±0.68μm). mgsA-deficient (mgsA - ) and -overexpressing (mgsA OE ) mutants also demonstrated cell shortening and elongation, similar to speB- and speE-deficient (speB - and speE - ) and -overexpressing (speB OE and speE OE ) mutants. Importantly, both mgsA-depleted speB OE and speE OE mutants (speB OE /mgsA - and speE OE /mgsA - ) were drastically shortened to 24.5% and 23.8% of parental speB OE and speE OE mutants, respectively. These phenotypes were associated with reciprocal alterations of mgsA and polyamine transcripts governed by the contents of methylglyoxal and spermidine, which are involved in enzymatic or genetic metabolite-control mechanisms. Additionally, biophysically detected methylglyoxal-spermidine Schiff bases did not affect morphogenesis. Taken together, the findings indicate that methylglyoxal triggers cell elongation. Furthermore, cells with methylglyoxal accumulation commonly exhibit an elongated rod-shaped morphology through upregulation of mgsA, polyamine genes, and the global regulator spx, as well as repression of the cell division and shape regulator, FtsZ. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Lidar measurements of boundary layer depolarization and CCSEM-EDX compositional analysis of airborne particles on collocated passive samplers throughout the forest canopy during the 2016 airborne pollen season at UMBS, Pellston, MI

    Science.gov (United States)

    Wozniak, M. C.; Steiner, A.; Ault, A. P.; Kort, E. A.; Lersch, T.; Casuccio, G.

    2017-12-01

    Observations of airborne pollen are typically made with volumetric samplers that obtain a time-averaged pollen concentration at a single point. While spatial variations in surface pollen concentrations may be known with these samplers given multiple sampling sites, real-time boundary layer transport of pollen grains cannot be determined except by particle dispersion or tracer transport models. Recently, light detection and ranging (lidar) techniques, such as depolarization, have been used to measure pollen transport and optical properties throughout the boundary layer over time. Here, we use a ground-based micro-pulse lidar (MPL) to observe boundary layer vertical profiles before, during and after the peak anemophilous (wind-driven) pollen season. The lidar depolarization ratio is measured in tandem with the normalized R-squared backscatter (NRB) intensity to determine the contribution of aspherical particles to the scatterers present throughout the boundary layer. Measurements are taken from April 15 - July 12, 2016 at the University of Michigan Biological Station (UMBS) PROPHET outdoor research lab and tower within a largely forested region. UMBS is dominated by Acer rubrum, Betula papyrifera, Pinus resinosa, Quercus rubra and Pinus strobus, all of which began flowering on 4/19, 5/3, 5/25, 5/25 and 6/14, respectively. Temperature, relative humidity and wind speed measured on site determine daytime conditions conducive to pollen dispersion from flowers. Lidar depolarization ratios between 0.08-0.14 and higher are observed in the daytime boundary layer on days shortly after the flowering dates of the aforementioned species, elevated above the background level of 0.06 or less. Lidar observations are supplemented with aerosol compositional analysis determined by computer-controlled scanning electron microscopy and energy-dispersive X-ray spectroscopy (CCSEM-EDX) on passive sampler data from below, within and above the forest canopy at PROPHET tower. Particles are

  20. Radial diffusive samplers for determination of 8-h concentration of BTEX, acetone, ethanol and ozone in ambient air during a sea breeze event

    Science.gov (United States)

    Roukos, Joelle; Locoge, Nadine; Sacco, Paolo; Plaisance, Hervé

    2011-01-01

    The radial diffusive sampler Radiello ® filled with Carbograph 4 was evaluated for monitoring BTEX, ethanol and acetone concentrations for 8-hour exposure time. The sampling rates were first evaluated in an exposure chamber under standard conditions. Benzene and toluene showed the highest sampling rates with satisfactory standard deviations. Ethylbenzene and xylenes showed medium sampling rates but higher standard deviations that can be attributed to a low affinity of these compounds with the adsorbent medium for short sampling time. Acetone has a fair result because of the increase of its partial pressure in the vicinity of the adsorbent surface in the course of sampling. The Carbograph 4 adsorbent does not seem to be suitable for sampling ethanol, likely because of its high volatility. The influences of three environmental factors (temperature (T), relative humidity (RH) and concentration level (C)) on the sampling rates were also evaluated, following a fractional factorial design at two factor levels (low and high). Results were only investigated on benzene, toluene and acetone. Temperature and relative humidity are found to be the most important factors leading to variability of the benzene and toluene sampling rates. The applicability of the sampler for 8-hour sampling was demonstrated by the results of a measurement campaign carried out during a sea breeze event. Mapping of benzene, toluene and acetone concentrations showed the highest concentrations in the industrial zone following the wind direction coming from the North. Nevertheless, the sea breeze tends to reduce the spread of the industrial plumes. On the contrary, the ozone map presents the lowest concentrations at the same industrial area indicating a net consumption of ozone. The highest ozone concentrations were found in the southeastern zone suggesting a local ozone formation.

  1. Graphene packed needle trap device as a novel field sampler for determination of perchloroethylene in the air of dry cleaning establishments.

    Science.gov (United States)

    Heidari, Mahmoud; Bahrami, Abdolrahman; Ghiasvand, Ali Reza; Emam, Maryam Rafiei; Shahna, Farshid Ghorbani; Soltanian, Ali Reza

    2015-01-01

    In this paper we describe the application of a needle trap microextraction device packed with graphene nanoplatelets for the sampling and analysis of perchloroethylene in dry cleaning. The study was carried out in two phases. First the parameters for the sampling and analysis of perchloroethylene by NTD were evaluated and optimized in the laboratory. Then the sampler was used to determine the levels of perchloroethylene in a dry-cleaning shop. In the laboratory phase of the study the performance of the NTD packed with the proposed sorbent was examined in a variety of sampling conditions to evaluate the technique. The technique was also compared with NTDs packed with PDMS as well as SPME with Carboxen/PDMS-coated fibers. Both the NTDs and SPME performed better at lower sampling temperatures and relative humidity levels. The post-sampling storage times for a 95% recovery of the analyte were 5, 5 and 3 days for NTD-graphene, NTD-PDMS and SPME-CAR/PDMS respectively. The optimum desorption time was 3 min for NTDs packed with either graphene or PDMS and 1 min for SPME-CAR/PDMS. The limits of detection for the GC/MS detection system were 0.023 and 0.25 ng mL(-1) for NTDs packed with graphene and PDMS and 0.014 ng mL(-1) for SPME coated with CAR/PDMS. In the second stage of the study the evaluated technique was applied to the sampling and analysis of perchloroethylene in dry cleaning. In this environment the performance of the NTD-graphene as a field sampler for PCE was similar to that of the SPME-CA/PDMS, and better than the NIOSH 1003 method which had greater measurement variations. The results show that a NTD packed with carbonic graphene nanoplatelets and used as an active exhaustive sampling technique is effective for determination of VOC and HVOC occupational/environmental pollutants in air. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. Assessment of polycyclic aromatic hydrocarbon contamination of the Bílina River (Czech Republic using passive water samplers and fish biliary metabolites

    Directory of Open Access Journals (Sweden)

    Jana Blahová

    2011-01-01

    Full Text Available The aim of the study was to assess polycyclic aromatic hydrocarbon (PAH contamination on the Bílina River (the Czech Republic by measurement of three PAH biliary metabolites in fish and 16 PAHs in passive samplers. A total of sixty-one fish were collected; the indicator species were chub (Leuciscus cephalus L.; n = 25, roach (Rutilus rutilus L.; n = 17 and brown trout (Salmo trutta m. fario L.; n = 19. Three biliary PAH metabolites were measured: 1-hydroxypyrene (1-OHP, 2-naphtol, and 1-hydroxyphenanthrene, but only 1-OHP was detected in all fish. The highest median value of 32.3 ng·mg-1of 1-OHP was found at Ústí nad Labem, while the lowest median value of 27.6 ng·mg-1was found in the control site, Březenec. No significant differences (P < 0.05 among the sites were found. The highest concentration of PAH was detected in Litvínov-Záluží (172.0 ng·l-1 and the lowest concentration (7.9 ng·l-1 was detected in Březenec. A positive, but non-significant correlation (rs = 0.8 was confirmed between biliary 1-OHP and total PAH in passive samplers. These results indicate the highest pollution in the middle stretches of the Bílina River, especially at Litvínov-Záluží. We confirmed 1-OHP as the most prevalent PAH biliary metabolite in fish that could be used as a biomarker for assessment of PAH pollution of the aquatic ecosystem. The main importance of the present study is in the combination of biochemical and chemical monitoring that provides complex evaluation of aquatic environment contamination. It was the first study on the Bílina River, in which the assessment of PAH contamination in the aquatic ecosystem was realized using combination of biotic and abiotic monitoring.

  3. Get Involved in Education and Public Outreach! The Science Mission Directorate Science E/PO Forums Are Here to Help

    Science.gov (United States)

    Shipp, S. S.; Buxner, S.; Schwerin, T. G.; Hsu, B. C.; Peticolas, L. M.; Smith, D.; Meinke, B. K.

    2013-12-01

    NASA's Science Mission Directorate (SMD) Education and Public Outreach (E/PO) Forums help to engage, extend, support, and coordinate the efforts of the community of E/PO professionals and scientists involved in Earth and space science education activities. This work is undertaken to maximize the effectiveness and efficiency of the overall national NASA science education and outreach effort made up of individual efforts run by these education professionals. This includes facilitating scientist engagement in education and outreach. The Forums have been developing toolkits and pathways to support planetary, Earth, astrophysics, and heliophysics scientists who are - or who are interested in becoming - involved in E/PO. These tools include: 1) Pathways to learn about SMD and E/PO community announcements and opportunities, share news about E/PO programs, let the E/PO community know you are interested in becoming involved, and discover education programs needing scientist input and/or support. These pathways include weekly e-news, the SMD E/PO online community workspace, monthly community calls, conferences and meetings of opportunity. 2) Portals to help you find out what education resources already exist, obtain resources to share with students of all levels - from K-12 to graduate students, - and disseminate your materials. These include E/PO samplers and toolkits (sampling of resources selected for scientists who work with students, teachers, and the public), the one-stop shop of reviewed resources from the NASA Earth and space science education portfolio NASAWavelength.org, and the online clearinghouse of Earth and space science higher education materials EarthSpace (http://www.lpi.usra.edu/earthspace). 3) Connections to education specialists who can help you design and implement meaningful E/PO programs - small to large. Education specialists can help you understand what research says about how people learn and effective practices for achieving your goals, place your

  4. Considering treatment of male genital schistosomiasis as a tool for future HIV prevention

    DEFF Research Database (Denmark)

    Stecher, Chalotte Willemann; Kallestrup, Per; Kjetland, Eyrun Floerecke

    2015-01-01

    OBJECTIVES: Male genital schistosomiasis (MGS) is a neglected manifestation of Schistosoma haematobium infection with ignored implications on reproductive health and a differential diagnosis to sexually transmitted infections in endemic regions. MGS may have associations with HIV transmission...... and acquisition, and treatment could be a neglected chance of HIV prevention. This review summarizes current knowledge on epidemiology, clinical manifestations, diagnosis and treatment of MGS as a hypothesized risk factor for HIV transmission. Future research areas of global interest are suggested. METHODS: Pub...... association between MGS and HIV are urgently needed. Furthermore, field diagnostic tools should be developed and future mass treatment programs should include adults to reduce morbidity and prevent HIV acquisition. SYSTEMATIC REVIEW REGISTRATION NUMBER: CRD42015016252....

  5. Revealing flow behaviors of metallic glass based on activation of flow units

    Energy Technology Data Exchange (ETDEWEB)

    Ge, T. P.; Wang, W. H.; Bai, H. Y., E-mail: hybai@iphy.ac.cn [Institute of Physics, Chinese Academy of Sciences, Beijing 100190 (China)

    2016-05-28

    Atomic level flow plays a critical role in the mechanical behavior of metallic glass (MG) while the connection between the flow and the heterogeneous microstructure of the glass remains unclear. We describe the heterogeneity of MGs as the elastic matrix with “inclusions” of nano-scale liquid-like flow units, and the plastic flow behavior of MGs is considered to be accommodated by the flow units. We show that the model can explain the various deformation behaviors, the transformation from inhomogeneous deformation to homogeneous flow upon strain rate or temperature, and the deformation map in MGs, which might provide insights into the flow mechanisms in glasses and inspiration for improving the plasticity of MGs.

  6. Stress analysis of shielded receiver lifting frame for core sampler truck number-sign 2

    International Nuclear Information System (INIS)

    Ziada, H.H.

    1994-01-01

    This analysis evaluates the structural design adequacy of the shielded receiver lifting frame (SRLF) for the rotary mode core sampler truck number 2 (RMCST number-sign 2). The analysis considers the loads expected during operation of the SRLF. Most of the existing welds were not in conformance with those specified on the drawings, H-2-91715 and -91716 (RHO 1988a and RHO 1988b). Stress analysts and engineers examined the configuration of the welds connecting the frame members of the SRLF and those connecting the SRLF to the drill rig. In comparison to those shown on the drawing, some of the actual welds appear stronger and others undersized. For example, the actual fillet welds completely encircle the junctures of members, although the drawings show some welds to be on two sides only. Attempts to find the original design calculations were unsuccessful. To resolve the nonconformance, the critical welds were identified by analysis and subsequently inspected to ensure they are as large or larger than the minimum is defined by weld leg size. A required weld size, as determined by stress analysis, of 0.1 inch or larger is considered to be critical. This size was selected because no existing welds were found to be less than 0.125 inch. Analysis results led to weld modifications to strengthen the SRLF. The weld modifications performed are described in WHC 1994

  7. Calibration of silicone rubber rods as passive samplers for pesticides at two different flow velocities: Modeling of sampling rates under water boundary layer and polymer control.

    Science.gov (United States)

    Martin, Alexis; Margoum, Christelle; Jolivet, Antoine; Assoumani, Azziz; El Moujahid, Bachir; Randon, Jérôme; Coquery, Marina

    2018-04-01

    There is a need to determine time-weighted average concentrations of polar contaminants such as pesticides by passive sampling in environmental waters. Calibration data for silicone rubber-based passive samplers are lacking for this class of compounds. The calibration data, sampling rate (R s ), and partition coefficient between silicone rubber and water (K sw ) were precisely determined for 23 pesticides and 13 candidate performance reference compounds (PRCs) in a laboratory calibration system over 14 d for 2 water flow velocities, 5 and 20 cm s -1 . The results showed that an in situ exposure duration of 7 d left a silicone rubber rod passive sampler configuration in the linear or curvilinear uptake period for 19 of the pesticides studied. A change in the transport mechanism from polymer control to water boundary layer control was observed for pesticides with a log K sw of approximately 3.3. The PRC candidates were not fully relevant to correct the impact of water flow velocity on R s . We therefore propose an alternative method based on an overall resistance to mass transfer model to adjust R s from laboratory experiments to in situ hydrodynamic conditions. We estimated diffusion coefficients (D s ) and thickness of water boundary layer (δ w ) as adjustable model parameters. Log D s values ranged from -12.13 to -10.07 m 2  s -1 . The estimated δ w value showed a power function correlation with water flow velocity. Environ Toxicol Chem 2018;37:1208-1218. © 2017 SETAC. © 2017 SETAC.

  8. Declines in arrestin and rhodopsin in the macula with progression of age-related macular degeneration.

    Science.gov (United States)

    Ethen, Cheryl M; Feng, Xiao; Olsen, Timothy W; Ferrington, Deborah A

    2005-03-01

    Biochemical analysis of age-related macular degeneration (AMD) at distinct stages of the disease will help further understanding of the molecular events associated with disease progression. This study was conducted to determine the ability of a new grading system for eye bank eyes, the Minnesota Grading System (MGS), to discern distinct stages of AMD so that retinal region-specific changes in rod photoreceptor protein expression from donors could be determined. Donor eyes were assigned to a specific level of AMD by using the MGS. Expression of the rod photoreceptor proteins rhodopsin and arrestin was evaluated by Western immunoblot analysis in the macular and peripheral regions of the neurosensory retina from donors at different stages of AMD. A significant linear decline in both arrestin and rhodopsin content correlated with progressive MGS levels in the macula. In contrast, the peripheral region showed no significant correlation between MGS level and the content of either protein. The statistically significant relationship between decreasing macular rod photoreceptor proteins and progressive MGS levels of AMD demonstrates the utility of the clinically based MGS to correspond with specific protein changes found at known, progressive stages of degeneration. Future biochemical analysis of clinically characterized donor eyes will further understanding of the pathobiochemistry of AMD.

  9. Honey Bees (Apis mellifera, L.) as Active Samplers of Airborne Particulate Matter.

    Science.gov (United States)

    Negri, Ilaria; Mavris, Christian; Di Prisco, Gennaro; Caprio, Emilio; Pellecchia, Marco

    2015-01-01

    Honey bees (Apis mellifera L.) are bioindicators of environmental pollution levels. During their wide-ranging foraging activity, these hymenopterans are exposed to pollutants, thus becoming a useful tool to trace the environmental contaminants as heavy metals, pesticides, radionuclides and volatile organic compounds. In the present work we demonstrate that bees can also be used as active samplers of airborne particulate matter. Worker bees were collected from hives located in a polluted postmining area in South West Sardinia (Italy) that is also exposed to dust emissions from industrial plants. The area is included in an official list of sites of national interest for environmental remediation, and has been characterized for the effects of pollutants on the health of the resident population. The head, wings, hind legs and alimentary canal of the bees were investigated with Scanning Electron Microscopy coupled with X-ray spectroscopy (SEM-EDX). The analyses pointed to specific morphological and chemical features of the particulate, and resulted into the identification of three categories of particles: industry-, postmining-, and soil-derived. With the exception of the gut, all the analyzed body districts displayed inorganic particles, mostly concentrated in specific areas of the body (i.e. along the costal margin of the fore wings, the medial plane of the head, and the inner surface of the hind legs). The role of both past mining activities and the industrial activity close to the study area as sources of the particulate matter is also discussed. We conclude that honey bees are able to collect samples of the main airborne particles emitted from different sources, therefore could be an ideal tool for monitoring such a kind of pollutants.

  10. Morning Glory Syndrome with Carotid and Middle Cerebral Artery Vasculopathy.

    Science.gov (United States)

    Nezzar, Hachemi; Mbekeani, Joyce N; Dalens, Helen

    2015-12-01

    To report a case of incidental asymptomatic atypical morning glory syndrome (MGS) with concomitant ipsilateral carotid and middle cerebral dysgenesis. A 6-year-old child was discovered to have incidental findings of MGS, with atypia. All visual functions were normal including vision and stereopsis. Neuroimaging revealed ipsilateral carotid and middle cerebral vascular narrowing without associated collateral vessels or cerebral ischemia commonly seen in Moyamoya disease. Subsequent annual examinations have been stable, without signs of progression. This case demonstrates disparity between structural aberrations and final visual and neurological function and reinforces the association between MGS and intracranial vascular disruption. Full ancillary ophthalmic and neuroimaging studies should be performed in all patients with MGS with interval reassessments, even when the patient is asymptomatic and functionally intact.

  11. The transition to efficiency in minority games

    International Nuclear Information System (INIS)

    Galla, Tobias; De Martino, Andrea

    2008-01-01

    The existence of a phase transition with diverging susceptibility in batch minority games (MGs) is the mark of informationally efficient regimes and is linked to the specifics of the agents' learning rules. Here, we study how the standard scenario is affected in a mixed population game in which agents with the 'optimal' learning rule (i.e. the one leading to efficiency) coexist with those whose adaptive dynamics is sub-optimal. Our generic finding is that any non-vanishing intensive fraction of optimal agents guarantees the existence of an efficient phase. Specifically, we calculate the dependence of the critical point on the fraction q of 'optimal' agents focusing our analysis on three cases: MGs with market impact correction, grand-canonical MGs and MGs with heterogeneous comfort levels

  12. Preliminary results on air pollution inside an iron metallurgical plant, using rotating streaker sampler and energy dispersive X-ray microfluorescence

    International Nuclear Information System (INIS)

    Nascimento Filho, V.F.; Silva, R.M.C.; Perez, C.A.

    2005-01-01

    Our aim was to study the chemical concentration of some metals in suspended particulate matter inside an-iron metallurgical plant. Using a rotating streaker air-particulate sampler with 8 and 0.45 microns pore diameter filter, it was possible to collect coarse and fine particulates during a week, with one hour step. After this, each strip of the filter was analyzed by energy dispersive x-ray microfluorescence (μ-EDXRF), using in the excitation a collimated x-ray line beam from a Mo target tube (30 kV, 20 mA, Zr filter) with a quartz capillary (120 mm long, 10 mm entrance diameter and 20 microns inner diameter at exit). The detection was carried out using a Si(Li) semiconductor detector coupled to a multichannel analyzer, and the X-ray spectra were fitted with the AXIL software. The profiles of several elements are shown and the results are discussed.

  13. The use of diffusive samplers for collecting organic gaseous constituents in waste gases. Diffusionssammler zur Probenahme von organischen gas- und dampffoermigen Substanzen in Abgasen

    Energy Technology Data Exchange (ETDEWEB)

    Canela, A.; Gruntz, U.; Muehleisen, H.; Tanner, S. (Sandoz AG, Basel (Switzerland). Umweltschutzlaboratorien)

    1990-01-01

    A relatively simple procedure for sample collection of multicomponent organic emissions is presented. A representative part of the waste gas is taken by means of a sampling probe and flows to the coupled sampling device. The gaseous constituents are collected in several diffusive samplers at the bottom of the device. Influencing parameters such as pressure, temperature, gas velocity etc., which may affect the collection rate and therefore the measured values, were investigated in the laboratory. Depending on the analytical detection limit, the sampling time and the diffusion parameters, the method can be applied for the determination of integrated emission concentrations between 0.1 mg/m{sup 3} and 1 g/m{sup 3}. (orig.).

  14. Meibomian gland dysfunction patients with novel Sjögren’s syndrome biomarkers benefit significantly from a single vectored thermal pulsation procedure: a retrospective analysis

    Directory of Open Access Journals (Sweden)

    Epitropoulos AT

    2017-04-01

    Full Text Available Alice T Epitropoulos,1,2 Krysta Goslin,2 Raman Bedi,3 Caroline A Blackie4 1Ophthalmic Surgeons and Consultants of Ohio, The Eye Center of Columbus, 2The Ohio State University Wexner Medical Center, Department of Ophthalmology, Columbus, OH, USA; 3Iris Advanced Eye Centre, Chandigarh, India; 4TearScience Inc., Morrisville, NC, USA Purpose: To measure the effects from a single vectored thermal pulsation treatment of the meibomian glands on dry eye signs and symptoms in patients who tested positively versus negatively for novel Sjögren’s syndrome (SS biomarkers. Methods: The retrospective study included the deidentified data of 102 eyes of 59 patients with dry eye and meibomian gland dysfunction (MGD, who were also tested for novel biomarkers for SS and underwent a single 12-minute LipiFlow thermal pulsation procedure. All patients were already being treated with individualized dry eye therapy but remained symptomatic. Meibomian gland secretion (MGS scores, Standard Patient Evaluation of Eye Dryness (SPEED questionnaire scores and tear breakup times (TBUTs before and 8 weeks after thermal pulsation treatment were analyzed. Results: Twenty-three patients tested positive for novel biomarkers of SS and 36 patients tested negative. At baseline, MGS, SPEED and TBUT of both SS-positive and SS-negative patients were equivalent. At 8 weeks’ post-treatment, mean MGS score, SPEED and TBUT were 13.0±7.8, 12.5±6.8 and 9.6±4.6, respectively, in SS-positive patients and 15.9±7.9, 10.0±6.3 and 8.3±4.6, respectively, in SS-negative patients (P<0.001. While the post-treatment MGS was significantly better in SS-negative patients than SS-positive (P=0.021, no significant difference between post-treatment SPEED and TBUT was observed between the two groups (P>0.05. Conclusion: LipiFlow treatment in MGD patients who were SS-positive for novel biomarkers of SS demonstrated improvement in signs and symptoms of dry eye. While improvement in MGS scores in SS

  15. Water-quality assessment of south-central Texas : comparison of water quality in surface-water samples collected manually and by automated samplers

    Science.gov (United States)

    Ging, Patricia B.

    1999-01-01

    Surface-water sampling protocols of the U.S. Geological Survey National Water-Quality Assessment (NAWQA) Program specify samples for most properties and constituents to be collected manually in equal-width increments across a stream channel and composited for analysis. Single-point sampling with an automated sampler (autosampler) during storms was proposed in the upper part of the South-Central Texas NAWQA study unit, raising the question of whether property and constituent concentrations from automatically collected samples differ significantly from those in samples collected manually. Statistical (Wilcoxon signed-rank test) analyses of 3 to 16 paired concentrations for each of 26 properties and constituents from water samples collected using both methods at eight sites in the upper part of the study unit indicated that there were no significant differences in concentrations for dissolved constituents, other than calcium and organic carbon.

  16. AKTIVITAS URIKASE YANG DIHASILKAN DARI BERBAGAI SEL LACTOBACILLUS PLANTARUM DAN PARAMETER KINETIKANYA

    Directory of Open Access Journals (Sweden)

    Dyah Iswantini

    2009-12-01

    Full Text Available Uric acid concentration could be determined by spectrophotometry method. Uric acid was oxidized into allatonin in the presence of uricase and calculated by measuring the decrease of uric acid absorbance at 293 nm. These uricase were obtained from cells of Lactobacillus plantarum. L. plantarum K. Mar. E was isolated from passion fruit skin and L. plantarum Mgs. Psmb and Mgs. Bst from mangosteen. This research was conducted to observe the activity and kinetics of uricase from various cells of L. plantarum by spectrophotometric method. The plate assay method indicated that L. plantarum produced uricase, based on the clear zone about 0,2 mm on glucose yeast peptone medium contained 0,2% uric acid. The optimum condition of uricase activity from the three different sources occured in physiological condition. Uricase activity generated from cells of L. plantarum K. Mar. E, Mgs. Psmb, and Mgs. Bst were 0,1073; 0,0867; and 0,0842 U/mL, respectively. The kinetic parameters for uricase, determined with uric acid as the substrate. Vmax produced by L. plantarum K. Mar. E, Mgs. Psmb, and Mgs. Bst were 1,3635; 0,0316; and 0,0418 U/mL of bacterial culture, respectively and KM 0,1541; 0,0061; and 0,0054 mM, respectively. Uricase activity in various bacterial cells of L. plantarum was stable until the second day

  17. Parahippocampal Involvement in Mesial Temporal Lobe Epilepsy with Hippocampal Sclerosis: A Proof of Concept from Memory-Guided Saccades

    Directory of Open Access Journals (Sweden)

    Silvia Colnaghi

    2017-11-01

    Full Text Available ObjectiveMesial temporal lobe epilepsy with hippocampal sclerosis (MTLE-HS may involve extrahippocampal areas of structural damage and dysfunction. The accuracy of medium-term spatial memory can be tested by memory-guided saccades (MGS to evaluate a functional impairment of the parahippocampal cortex (PHC, while voxel-based morphometry (VBM analysis can be used to detect a structural damage of the latter region.MethodsMGS with 3- and 30-s memorization delays were compared between 7 patients affected by right MTLE-HS (r-MTLE-HS, 6 patients affected by left MTLE-HS, and 13 healthy controls. The same subjects underwent brain MRI for a VBM analysis. Correlation analysis was performed between the results of VBM and MGS and with patients’ clinical data.ResultsRight MTLE-HS patients showed impaired accuracy of leftward MGS with a 30-s memorization delay; their gray-matter volume was reduced in the right hippocampus and inferior temporal gyrus, and bilaterally in the cerebellum. Left MTLE-HS patients had normal MGS accuracy; their gray-matter volume was reduced in the left hippocampus, in the right-inferior temporal gyrus and corpus callosus, and bilaterally in the insular cortex and in the cerebellum. The difference between right and left parahippocampal volumes correlated with MGS accuracy, while right and left hippocampal volumes did not. Hippocampal and parahippocampal volume did not correlate with clinical variables such as febrile seizures, age at disease onset, disease duration, and seizure frequency.ConclusionMGS abnormalities suggested the functional involvement of the right PHC in patients with r-MTLE-HS, supporting a right lateralization of spatial memory control and showing a relation between functional impairment and degree of atrophy.

  18. 4-Meter Gait Speed Test in Chronic Obstructive Pulmonary Disease: INTERRATER RELIABILITY USING A STOPWATCH.

    Science.gov (United States)

    Bisca, Gianna Waldrich; Fava, Lucas Rodrigues; Morita, Andrea Akemi; Machado, Felipe Vilaça Cavallari; Pitta, Fabio; Hernandes, Nidia Aparecida

    2017-12-14

    4-meter gait speed (4MGS) is increasingly used to assess functional performance in patients with chronic obstructive pulmonary disease. However, the current literature lacks information regarding some technical standards for this test. Therefore, the purpose of this study was to compare and to evaluate the interrater reliability between a stopwatch and video recording used as timing systems for the 4MGS in patients with chronic obstructive pulmonary disease, as well as to verify the interrater reliability between 2 observers measuring the 4MGS time using a manual stopwatch. Fifty-one patients performed the 4MGS using 4 different protocols (random order): walking at the usual and maximum speed in a 4-meter course and walking at the same 2 speeds on an 8-m course using a 2-m acceleration zone, a 4-meter timing area, and a 2-m deceleration zone. Gait speed was measured simultaneously using a stopwatch and a video recording. In a subanalysis (n = 24), 2 independent observers timed the 4MGS using a stopwatch. There was no significant difference in comparison between the 2 timing methods (P > .05 for all), and the reliability between video recording and stopwatch was excellent in all 4MGS studied protocols (intraclass correlation coefficient ≥ 0.91). Moreover, when comparing gait speed measured by 2 observers using a stopwatch, no significant difference was found among all proposed protocols (P > .05 for all), and there was also excellent reliability between the 2 independent observers (intraclass correlation coefficient ≥ 0.94). The stopwatch, a low-cost and feasible tool, is reliable as a timing device for the 4MGS in patients with chronic obstructive pulmonary disease.

  19. A comparison between anisotropic analytical and multigrid superposition dose calculation algorithms in radiotherapy treatment planning

    International Nuclear Information System (INIS)

    Wu, Vincent W.C.; Tse, Teddy K.H.; Ho, Cola L.M.; Yeung, Eric C.Y.

    2013-01-01

    Monte Carlo (MC) simulation is currently the most accurate dose calculation algorithm in radiotherapy planning but requires relatively long processing time. Faster model-based algorithms such as the anisotropic analytical algorithm (AAA) by the Eclipse treatment planning system and multigrid superposition (MGS) by the XiO treatment planning system are 2 commonly used algorithms. This study compared AAA and MGS against MC, as the gold standard, on brain, nasopharynx, lung, and prostate cancer patients. Computed tomography of 6 patients of each cancer type was used. The same hypothetical treatment plan using the same machine and treatment prescription was computed for each case by each planning system using their respective dose calculation algorithm. The doses at reference points including (1) soft tissues only, (2) bones only, (3) air cavities only, (4) soft tissue-bone boundary (Soft/Bone), (5) soft tissue-air boundary (Soft/Air), and (6) bone-air boundary (Bone/Air), were measured and compared using the mean absolute percentage error (MAPE), which was a function of the percentage dose deviations from MC. Besides, the computation time of each treatment plan was recorded and compared. The MAPEs of MGS were significantly lower than AAA in all types of cancers (p<0.001). With regards to body density combinations, the MAPE of AAA ranged from 1.8% (soft tissue) to 4.9% (Bone/Air), whereas that of MGS from 1.6% (air cavities) to 2.9% (Soft/Bone). The MAPEs of MGS (2.6%±2.1) were significantly lower than that of AAA (3.7%±2.5) in all tissue density combinations (p<0.001). The mean computation time of AAA for all treatment plans was significantly lower than that of the MGS (p<0.001). Both AAA and MGS algorithms demonstrated dose deviations of less than 4.0% in most clinical cases and their performance was better in homogeneous tissues than at tissue boundaries. In general, MGS demonstrated relatively smaller dose deviations than AAA but required longer computation time

  20. Waves in the middle and upper atmosphere of Mars as seen by the Radio Science Experiment MaRS on Mars Express

    Science.gov (United States)

    Tellmann, S.; Paetzold, M.; Häusler, B.; Hinson, D. P.; Peter, K.; Tyler, G. L.

    2017-12-01

    Atmospheric waves play a crucial role in the Martian atmosphere. They are responsible for the redistribution of momentum, energy and dust and for the coupling of the different atmospheric regions on Mars. Almost all kinds of waves have been observed in the lower atmosphere (e.g. stationary and transient waves, baroclinic waves as well as migrating and non-migrating thermal tides, gravity waves, etc...). Atmospheric waves are also known to exist in the middle atmosphere of Mars ( 70-120 km, e.g. by the SPICAM instrument on Mars Express). In the thermosphere, thermal tides have been observed e.g. by radio occultation or accelerometer measurements on MGS. Recently, the NGIMS instrument on MAVEN reported gravity waves in the thermosphere of Mars. Radio Science profiles from the Mars Express Radio Science experiment MaRS on Mars Express can analyse the temperature, pressure and neutral number density profiles in the lower atmosphere (from a few hundred metres above the surface up to 40-50 km) and electron density profiles in the ionosphere of Mars. Wavelike structures have been detected below the main ionospheric layers (M1 & M2) and in the topside of the ionosphere. The two coherent frequencies of the MaRS experiment allow to discriminate between plasma density fluctuations in the ionosphere and Doppler related frequency shifts caused by spacecraft movement. A careful analysis of the observed electron density fluctuations in combination with sensitivity studies of the radio occultation technique will be used to classify the observed fluctuations. The MaRS experiment is funded by DLR under grant 50QM1401.

  1. Generating functional analysis of minority games with inner product strategy definitions

    Science.gov (United States)

    Coolen, A. C. C.; Shayeghi, N.

    2008-08-01

    We use generating functional methods to solve the so-called inner product versions of the minority game (MG), with fake and/or real market histories, by generalizing the theory developed recently for look-up table MGs with real histories. The phase diagrams of the look-up table and inner product MG versions are generally found to be identical, with the exception of inner product MGs where histories are sampled linearly, which are found to be structurally critical. However, we encounter interesting differences both in the theory (where the role of the history frequency distribution in look-up table MGs is taken over by the eigenvalue spectrum of a history covariance matrix in inner product MGs) and in the static and dynamic phenomenology of the models. Our theoretical predictions are supported by numerical simulations.

  2. Generating functional analysis of minority games with inner product strategy definitions

    Energy Technology Data Exchange (ETDEWEB)

    Coolen, A C C; Shayeghi, N [Department of Mathematics, King' s College London, The Strand, London WC2R 2LS (United Kingdom)], E-mail: ton.coolen@kcl.ac.uk, E-mail: nima@mth.kcl.ac.uk

    2008-08-15

    We use generating functional methods to solve the so-called inner product versions of the minority game (MG), with fake and/or real market histories, by generalizing the theory developed recently for look-up table MGs with real histories. The phase diagrams of the look-up table and inner product MG versions are generally found to be identical, with the exception of inner product MGs where histories are sampled linearly, which are found to be structurally critical. However, we encounter interesting differences both in the theory (where the role of the history frequency distribution in look-up table MGs is taken over by the eigenvalue spectrum of a history covariance matrix in inner product MGs) and in the static and dynamic phenomenology of the models. Our theoretical predictions are supported by numerical simulations.

  3. Hierarchical Control for Optimal and Distributed Operation of Microgrid Systems

    DEFF Research Database (Denmark)

    Meng, Lexuan

    manages the power flow with external grids, while the economic and optimal operation of MGs is not guaranteed by applying the existing schemes. Accordingly, this project dedicates to the study of real-time optimization methods for MGs, including the review of optimization algorithms, system level...... mathematical modeling, and the implementation of real-time optimization into existing hierarchical control schemes. Efficiency enhancement in DC MGs and optimal unbalance compensation in AC MGs are taken as the optimization objectives in this project. Necessary system dynamic modeling and stability analysis......, a discrete-time domain modeling method is proposed to establish an accurate system level model. Taking into account the different sampling times of real world plant, digital controller and communication devices, the system is modeled with these three parts separately, and with full consideration...

  4. Generating functional analysis of minority games with inner product strategy definitions

    International Nuclear Information System (INIS)

    Coolen, A C C; Shayeghi, N

    2008-01-01

    We use generating functional methods to solve the so-called inner product versions of the minority game (MG), with fake and/or real market histories, by generalizing the theory developed recently for look-up table MGs with real histories. The phase diagrams of the look-up table and inner product MG versions are generally found to be identical, with the exception of inner product MGs where histories are sampled linearly, which are found to be structurally critical. However, we encounter interesting differences both in the theory (where the role of the history frequency distribution in look-up table MGs is taken over by the eigenvalue spectrum of a history covariance matrix in inner product MGs) and in the static and dynamic phenomenology of the models. Our theoretical predictions are supported by numerical simulations

  5. A suspended-particle rosette multi-sampler for discrete biogeochemical sampling in low-particle-density waters

    Energy Technology Data Exchange (ETDEWEB)

    Breier, J. A.; Rauch, C. G.; McCartney, K.; Toner, B. M.; Fakra, S. C.; White, S. N.; German, C. R.

    2010-06-22

    To enable detailed investigations of early stage hydrothermal plume formation and abiotic and biotic plume processes we developed a new oceanographic tool. The Suspended Particulate Rosette sampling system has been designed to collect geochemical and microbial samples from the rising portion of deep-sea hydrothermal plumes. It can be deployed on a remotely operated vehicle for sampling rising plumes, on a wire-deployed water rosette for spatially discrete sampling of non-buoyant hydrothermal plumes, or on a fixed mooring in a hydrothermal vent field for time series sampling. It has performed successfully during both its first mooring deployment at the East Pacific Rise and its first remotely-operated vehicle deployments along the Mid-Atlantic Ridge. It is currently capable of rapidly filtering 24 discrete large-water-volume samples (30-100 L per sample) for suspended particles during a single deployment (e.g. >90 L per sample at 4-7 L per minute through 1 {mu}m pore diameter polycarbonate filters). The Suspended Particulate Rosette sampler has been designed with a long-term goal of seafloor observatory deployments, where it can be used to collect samples in response to tectonic or other events. It is compatible with in situ optical sensors, such as laser Raman or visible reflectance spectroscopy systems, enabling in situ particle analysis immediately after sample collection and before the particles alter or degrade.

  6. Food control and a citizen science approach for improving teaching of Genetics in universities.

    Science.gov (United States)

    Borrell, Y J; Muñoz-Colmenero, A M; Dopico, E; Miralles, L; Garcia-Vazquez, E

    2016-09-10

    A Citizen Science approach was implemented in the laboratory practices of Genetics at the University of Oviedo, related with the engaging topic of Food Control. Real samples of food products consumed by students at home (students as samplers) were employed as teaching material in three different courses of Genetics during the academic year 2014-2015: Experimental Methods in Food Production (MBTA) (Master level), and Applied Molecular Biology (BMA) and Conservation Genetics and Breeding (COMGE) (Bachelor/Degree level). Molecular genetics based on PCR amplification of DNA markers was employed for species identification of 22 seafood products in COMGE and MBTA, and for detection of genetically modified (GM) maize from nine products in BMA. In total six seafood products incorrectly labeled (27%), and two undeclared GM maize (22%) were found. A post-Laboratory survey was applied for assessing the efficacy of the approach for improving motivation in the Laboratory Practices of Genetics. Results confirmed that students that worked on their own samples from local markets were significantly more motivated and better evaluated their Genetic laboratory practices than control students (χ(2)  = 12.11 p = 0.033). Our results suggest that citizen science approaches could not be only useful for improving teaching of Genetics in universities but also to incorporate students and citizens as active agents in food control. © 2016 by The International Union of Biochemistry and Molecular Biology, 44(5):450-462, 2016. © 2016 The International Union of Biochemistry and Molecular Biology.

  7. Comparison of Anti-Obesity Effect between Two Types of Syrup Containing Rare Sugars in Wistar Rats.

    Science.gov (United States)

    Ochiai, Masaru; Misaki, Kohei; Yamada, Takako; Iida, Tetsuo; Okuma, Kazuhiro; Matsuo, Tatsuhiro

    2017-01-01

    D-Allulose-containing rare sugar sweeteners have been categorized into two types, rare sugar syrup (RSS), consisting of 4 rare monosaccharides, and modified glucose syrup (MGS), rich in D-allulose, which was previously referred to D-psicose. The anti-obesity effect of RSS and D-allulose has been already clarified, but that of rare monosaccharides other than D-allulose in RSS has not yet been well understood. Here, we investigated and compared the anti-obesity effect of RSS and MGS in rats. Male Wistar rats were divided into 4 dietary groups: a high-sucrose control diet group (S), a high-fructose corn syrup diet group (HFCS), an RSS diet group (RSS), and an MGS diet group (MGS). RSS significantly suppressed abdominal adipose tissue weight and total body fat accumulation in comparison to sucrose. On the other hand, MGS reduced body weight gain, but not abdominal fat accumulation, relative to sucrose. The weight of the liver and kidneys was significantly higher in the RSS and MGS groups than in the S and HFCS groups, but serum biochemical parameters and hepatic lipids contents were not significantly different among the groups. The present study shows that two types of D-allulose-containing rare sugar sweeteners can suppress body fat accumulation or weight gain in a different manner and that RSS could be used as more effective sweeteners in place of sucrose and HFCS to maintain healthy body weight.

  8. Ecological Risk Assessment of Perchlorate in Avian Species, Rodents, Amphibians and Fish

    Science.gov (United States)

    2003-04-01

    http://www .indiana.edu/- axolotl ). 10.0 JUSTIFICATION OF TEST SYSTEM Perchlorate occurs in ground and surface waters in 44 states in the USA... axolotl ). * Sequentially numbered in order of the date that the change is effective Dept. of Biological Sciences (DBS) Box 43131 Lubbock, TX 79409...KCl, 0.025 giL; CaCh2 H20, 0.65 g/L; MgS04·7H20, 0.1 giL (http://www.indiana.edu/~ axolotl ). *Sequentially numbered in order of the date that the

  9. An overview on the conventional and nonconventional methods for manufacturing the metallic glasses

    Directory of Open Access Journals (Sweden)

    Axinte Eugen

    2017-01-01

    Full Text Available Metallic glasses (MGs, first discovered in 1959 at Caltech are currently among the most studied metallic materials. MGs called also glassy metals, amorphous metals, liquid metals, are considered to be among the materials of the future. The “classic” methods for industrialization of MGs are : end-casting in copper molds and protected environment, die forging , atomization for obtaining MG powder ,selective laser melting , imprinting in molds, thermoplastic shaping in the super-cooled temperature region. These methods are suitable for producing high value-added precision components but the problems still exists: expensive tools, limited lifetime of tools and the occurring of crystallization. Actually methods (thermoplastic shaping, casting and die forging are limited by the low flexibility of production and by higher costs of tools and accessories. More suitable methods are greatly desired to machine MGs for their wider applications.

  10. Analysis of hydrogen and methane in seawater by "Headspace" method: Determination at trace level with an automatic headspace sampler.

    Science.gov (United States)

    Donval, J P; Guyader, V

    2017-01-01

    "Headspace" technique is one of the methods for the onboard measurement of hydrogen (H 2 ) and methane (CH 4 ) in deep seawater. Based on the principle of an automatic headspace commercial sampler, a specific device has been developed to automatically inject gas samples from 300ml syringes (gas phase in equilibrium with seawater). As valves, micro pump, oven and detector are independent, a gas chromatograph is not necessary allowing a reduction of the weight and dimensions of the analytical system. The different steps from seawater sampling to gas injection are described. Accuracy of the method is checked by a comparison with the "purge and trap" technique. The detection limit is estimated to 0.3nM for hydrogen and 0.1nM for methane which is close to the background value in deep seawater. It is also shown that this system can be used to analyze other gases such as Nitrogen (N 2 ), carbon monoxide (CO), carbon dioxide (CO 2 ) and light hydrocarbons. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Exposure of bakery and pastry apprentices to airborne flour dust using PM2.5 and PM10 personal samplers

    Directory of Open Access Journals (Sweden)

    Paris Christophe

    2007-11-01

    Full Text Available Abstract Background This study describes exposure levels of bakery and pastry apprentices to flour dust, a known risk factor of occupational asthma. Methods Questionnaires on work activity were completed by 286 students. Among them, 34 performed a series of two personal exposure measurements using a PM2.5 and PM10 personal sampler during a complete work shift, one during a cold ("winter" period, and the other during a hot ("summer" period. Results Bakery apprentices experience greater average PM2.5 and PM10 exposures than pastry apprentices (p 10 values among bakers = 1.10 mg.m-3 [standard deviation: 0.83] than in summer (0.63 mg.m-3 [0.36]. While complying with current European occupational limit values, these exposures exceed the ACGIH recommendations set to prevent sensitization to flour dust (0.5 mg.m-3. Over half the facilities had no ventilation system. Conclusion Young bakery apprentices incur substantial exposure to known airways allergens, a situation that might elicit early induction of airways inflammation.

  12. Exposure of bakery and pastry apprentices to airborne flour dust using PM2.5 and PM10 personal samplers.

    Science.gov (United States)

    Mounier-Geyssant, Estelle; Barthélemy, Jean-François; Mouchot, Lory; Paris, Christophe; Zmirou-Navier, Denis

    2007-11-01

    This study describes exposure levels of bakery and pastry apprentices to flour dust, a known risk factor of occupational asthma. Questionnaires on work activity were completed by 286 students. Among them, 34 performed a series of two personal exposure measurements using a PM2.5 and PM10 personal sampler during a complete work shift, one during a cold ("winter") period, and the other during a hot ("summer") period. Bakery apprentices experience greater average PM2.5 and PM10 exposures than pastry apprentices (p < 0.006). Exposure values for both particulate fractions are greater in winter (average PM10 values among bakers = 1.10 mg.m-3 [standard deviation: 0.83]) than in summer (0.63 mg.m-3 [0.36]). While complying with current European occupational limit values, these exposures exceed the ACGIH recommendations set to prevent sensitization to flour dust (0.5 mg.m-3). Over half the facilities had no ventilation system. Young bakery apprentices incur substantial exposure to known airways allergens, a situation that might elicit early induction of airways inflammation.

  13. PCDD, PCDF, dl-PCB and organochlorine pesticides monitoring in São Paulo City using passive air sampler as part of the Global Monitoring Plan.

    Science.gov (United States)

    Tominaga, M Y; Silva, C R; Melo, J P; Niwa, N A; Plascak, D; Souza, C A M; Sato, M I Z

    2016-11-15

    The persistent organic pollutants (POPs), such as organochlorine pesticides and PCBs, are ordinarily monitored in the aquatic environment or in soil in the environmental quality monitoring programs in São Paulo, Brazil. One of the core matrices proposed in the POPs Global Monitoring Plan (GMP) from the Stockholm Convention list is the ambient air, which is not a usual matrix for POPs monitoring in the country. In this study POP levels were evaluated in the air samples from an urban site in São Paulo City over five years, starting in 2010 as a capacity building project for Latin America and the Caribbean region for POP monitoring in ambient air using passive samplers. Furthermore, after the end of the Project in 2012, the monitoring continued in the same sampling site as means to improving the analytical capacity building and contribute to the GMP data. The POPs monitored were 17 congeners of 2,3,7,8 chloro-substituted PCDDs and PCDFs, dioxin-like PCBs, indicator PCBs, organochlorine pesticides and toxaphene. The results show a slight decrease in PCDD/F, dl-PCBs and indicator PCBs levels along the five years. The organochlorine pesticide endosulfan was present at its highest concentration at the beginning of the monitoring period, but it was below detection level in the last year of the monitoring. Some other organochlorine pesticides were detected close to or below quantitation limits. The compounds identified were dieldrin, chlordane, α-HCH, γ-HCH, heptachlor, heptachlor epoxide, hexachlorobenzene and DDTs. Toxaphene congeners were not detected. These results have confirmed the efficacy of passive sampling for POP monitoring and the capacity building for POP analysis and monitoring was established. However more needs to be done, including expansion of sampling sites, new POPs and studies on sampling rates to be considered in calculating the concentration of POPs in ambient air using a passive sampler. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. Earth's Largest Terrestrial Landslide (The Markagunt Gravity Slide of Southwest Utah): Insights from the Catastrophic Collapse of a Volcanic Field

    Science.gov (United States)

    Hacker, D. B.; Biek, R. F.; Rowley, P. D.

    2015-12-01

    The newly discovered Miocene Markagunt gravity slide (MGS; Utah, USA) represents the largest volcanic landslide structure on Earth. Recent geologic mapping of the MGS indicates that it was a large contiguous volcanic sheet of allochthonous andesitic mudflow breccias and lava flows, volcaniclastic rocks, and intertonguing regional ash-flow tuffs that blanketed an area of at least 5000 km2 with an estimated volume of ~3000 km3. From its breakaway zone in the Tushar and Mineral Mountains to its southern limits, the MGS is over 95 km long and at least 65 km wide. The MGS consists of four distinct structural segments: 1) a high-angle breakaway segment, 2) a bedding-plane segment, ~60 km long and ~65 km wide, typically located within the volcaniclastic Eocene-Oligocene Brian Head Formation, 3) a ramp segment ~1-2 km wide where the slide cuts upsection, and 4) a former land surface segment where the upper-plate moved at least 35 km over the Miocene landscape. The presence of basal and lateral cataclastic breccias, clastic dikes, jigsaw puzzle fracturing, internal shears, pseudotachylytes, and the overall geometry of the MGS show that it represents a single catastrophic emplacement event. The MGS represents gravitationally induced collapse of the southwest sector of the Oligocene to Miocene Marysvale volcanic field. We suggest that continuous growth of the Marysvale volcanic field, loading more volcanic rocks on a structurally weak Brian Head basement, created conditions necessary for gravity sliding. In addition, inflation of the volcanic pile due to multiple magmatic intrusions tilted the strata gently southward, inducing lateral spreading of the sub-volcanic rocks prior to failure. Although similar smaller-scale failures have been recognized from individual volcanoes, the MGS represents a new class of low frequency but high impact hazards associated with catastrophic sector collapse of large volcanic fields containing multiple volcanoes. The relationship of the MGS to

  15. Determination of chemical availability of cadmium and zinc in soils using inert soil moisture samplers.

    Science.gov (United States)

    Knight, B P; Chaudri, A M; McGrath, S P; Giller, K E

    1998-01-01

    A rapid method for extracting soil solutions using porous plastic soil-moisture samplers was combined with a cation resin equilibration based speciation technique to look at the chemical availability of metals in soil. Industrially polluted, metal sulphate amended and sewage sludge treated soils were used in our study. Cadmium sulphate amended and industrially contaminated soils all had > 65% of the total soil solution Cd present as free Cd2+. However, increasing total soil Cd concentrations by adding CdSO4 resulted in smaller total soil solution Cd. Consequently, the free Cd2+ concentrations in soil solutions extracted from these soils were smaller than in the same soil contaminated by sewage sludge addition. Amendment with ZnSO4 gave much greater concentrations of free Zn2+ in soil solutions compared with the same soil after long-term Zn contamination via sewage sludge additions. Our results demonstrate the difficulty in comparing total soil solution and free metal ion concentrations for soils from different areas with different physiochemical properties and sources of contamination. However, when comparing the same Woburn soil, Cd was much less available as Cd2+ in soil solution from the CdSO4 amended soils compared with soil contaminated by about 36 years of sewage sludge additions. In contrast, much more Zn was available in soil solution as free Zn2+ in the ZnSO4 amended soils compared with the sewage sludge treated soils.

  16. Biological, physical, nutrients, sediment, and other data from sediment sampler-grab, bottle, and CTD casts in the Arabian Sea, Equatorial Pacific Ocean, Northeast Atlantic Ocean, and Southern Oceans as part of the Long Term Monitoring East-West Flower Garden Banks project from 08 January 1995 to 08 April 1998 (NODC Accession 0001155)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Biological, physical, nutrients, sediment, and other data were collected using sediment sampler-grab, bottle and CTD casts in the Arabian Sea, North/South Pacific...

  17. Synthesis, characterization and field evaluation of a new calcium-based CO2 absorbent for radial diffusive sampler

    Science.gov (United States)

    Cucciniello, Raffaele; Proto, Antonio; Alfano, Davide; Motta, Oriana

    2012-12-01

    In this paper the use of passive sampling as a powerful approach to monitor atmospheric CO2 is assessed. Suitable substrate based on calcium-aluminium oxide was synthetized according to a process which permits to control the particle size of the CaO/Al based sorbent. The study shows that hydration of substrate is an essential part of the process of CO2 absorption and subsequent conversion to carbonate. X-ray diffraction, thermogravimetric analysis, environmental scanning electron microscopic analysis were used in order to characterize the substrate and to establish the best performances both in terms of particle size and CO2 absorption capacity. Passive samplers for CO2 monitoring were prepared and then tested at laboratory level and in the atmospheric environment. Validation was performed by comparison with an infrared continuous detector. Thermogravimetric analysis results, carried out to evaluate the absorbing capability of this new passive device, were in accordance with data collected at the same time by the active continuous analyser. The diffusive sampling rate and the diffusion coefficient of CO2 respect to this new passive device were also evaluated resulting equal to 47 ± 3 ml min-1 and 0.0509 ± 0.005 cm2 s-1, respectively.

  18. Estimating pesticide sampling rates by the polar organic chemical integrative sampler (POCIS) in the presence of natural organic matter and varying hydrodynamic conditions

    Science.gov (United States)

    Charlestra, Lucner; Amirbahman, Aria; Courtemanch, David L.; Alvarez, David A.; Patterson, Howard

    2012-01-01

    The polar organic chemical integrative sampler (POCIS) was calibrated to monitor pesticides in water under controlled laboratory conditions. The effect of natural organic matter (NOM) on the sampling rates (Rs) was evaluated in microcosms containing -1 of total organic carbon (TOC). The effect of hydrodynamics was studied by comparing Rs values measured in stirred (SBE) and quiescent (QBE) batch experiments and a flow-through system (FTS). The level of NOM in the water used in these experiments had no effect on the magnitude of the pesticide sampling rates (p > 0.05). However, flow velocity and turbulence significantly increased the sampling rates of the pesticides in the FTS and SBE compared to the QBE (p < 0.001). The calibration data generated can be used to derive pesticide concentrations in water from POCIS deployed in stagnant and turbulent environmental systems without correction for NOM.

  19. Foundations of combinatorics with applications

    CERN Document Server

    Bender, Edward A

    2006-01-01

    This introduction to combinatorics, the foundation of the interaction between computer science and mathematics, is suitable for upper-level undergraduates and graduate students in engineering, science, and mathematics.The four-part treatment begins with a section on counting and listing that covers basic counting, functions, decision trees, and sieving methods. The following section addresses fundamental concepts in graph theory and a sampler of graph topics. The third part examines a variety of applications relevant to computer science and mathematics, including induction and recursion, sorti

  20. Monitoring for contaminants of emerging concern in drinking water using POCIS passive samplers.

    Science.gov (United States)

    Metcalfe, Chris; Hoque, M Ehsanul; Sultana, Tamanna; Murray, Craig; Helm, Paul; Kleywegt, Sonya

    2014-03-01

    Contaminants of emerging concern (CEC) have been detected in drinking water world-wide. The source of most of these compounds is generally attributed to contamination from municipal wastewater. Traditional water sampling methods (grab or composite) often require the concentration of large amounts of water in order to detect trace levels of these contaminants. The Polar Organic Compounds Integrative Sampler (POCIS) is a passive sampling technology that has been developed to concentrate trace levels of CEC to provide time-weighted average concentrations for individual compounds in water. However, few studies to date have evaluated whether POCIS is suitable for monitoring contaminants in drinking water. In this study, the POCIS was evaluated as a monitoring tool for CEC in drinking water over a period of 2 and 4 weeks with comparisons to typical grab samples. Seven "indicator compounds" which included carbamazepine, trimethoprim, sulfamethoxazole, ibuprofen, gemfibrozil, estrone and sucralose, were monitored in five drinking water treatment plants (DWTPs) in Ontario. All indicator compounds were detected in raw water samples from the POCIS in comparison to six from grab samples. Similarly, four compounds were detected in grab samples of treated drinking water, whereas six were detected in the POCIS. Sucralose was the only compound that was detected consistently at all five plants. The POCIS technique provided integrative exposures of CECs in drinking water at lower detection limits, while episodic events were captured via traditional sampling methods. There was evidence that the accumulation of target compounds by POCIS is a dynamic process, with adsorption and desorption on the sorbent occurring in response to ambient levels of the target compounds in water. CECs in treated drinking water were present at low ng L(-1) concentrations, which are not considered to be a threat to human health.

  1. Low specific-grinding energy machining of ceramics by a laser dressed diamond grinding stone

    International Nuclear Information System (INIS)

    Jodan, K.; Matsumaru, K.; Ishizaki, K.

    2003-01-01

    A laser dressing is an effective dressing method to accomplish efficient ceramic grinding. Since laser dressing achieves protrusion heights of abrasive-grains without grain dislodgment, the number of abrasive-grains in a laser dressed grinding stone (LGS) is higher than that in a mechanically dressed grinding stone (MGS), remaining the initial grain distribution. Thus, the LGS contains higher number of effective cutting edges, and forms higher number of ground grooves on a ground surface than the MGS. Consequently, the LGS can achieve lower specific grinding energy than the MGS. Copyright (2003) AD-TECH - International Foundation for the Advancement of Technology Ltd

  2. Non-localized deformation in Cu−Zr multi-layer amorphous films under tension

    Energy Technology Data Exchange (ETDEWEB)

    Zhong, C. [International Center for New-Structured Materials (ICNSM), Laboratory of New-Structured Materials, State Key Laboratory of Silicon Materials, and School of Materials Science and Engineering, Zhejiang University, Hangzhou 310027 (China); Zhang, H. [International Center for New-Structured Materials (ICNSM), Laboratory of New-Structured Materials, State Key Laboratory of Silicon Materials, and School of Materials Science and Engineering, Zhejiang University, Hangzhou 310027 (China); Department of Chemical and Materials Engineering, University of Alberta, Edmonton, Alberta T6G 1H9 (Canada); Cao, Q.P.; Wang, X.D. [International Center for New-Structured Materials (ICNSM), Laboratory of New-Structured Materials, State Key Laboratory of Silicon Materials, and School of Materials Science and Engineering, Zhejiang University, Hangzhou 310027 (China); Zhang, D.X. [State Key Laboratory of Modern Optical Instrumentation, Zhejiang University, Hangzhou 310027 (China); Hu, J.W. [Hangzhou Workers Amateur University, Hangzhou 310027 (China); Liaw, P.K. [Department of Materials Science and Engineering, The University of Tennessee, Knoxville, TN 37996 (United States); Jiang, J.Z., E-mail: jiangjz@zju.edu.cn [International Center for New-Structured Materials (ICNSM), Laboratory of New-Structured Materials, State Key Laboratory of Silicon Materials, and School of Materials Science and Engineering, Zhejiang University, Hangzhou 310027 (China)

    2016-09-05

    In metallic glasses (MGs), plastic deformation at room temperature is dominated by highly localized shear bands. Here we report the non-localized deformation under tension in Cu−Zr multi-layer MGs with a pure amorphous structure using large-scale atomistic simulations. It is demonstrated that amorphous samples with high layer numbers, composed of Cu{sub 64}Zr{sub 36} and Cu{sub 40}Zr{sub 60}, or Cu{sub 64}Zr{sub 36} and Cu{sub 50}Zr{sub 50}, present obviously non-localized deformation behavior. We reveal that the deformation behavior of the multi-layer-structured MG films is related but not determined by the deformation behavior of the composed individual layers. The criterion for the deformation mode change for MGs with a pure amorphous structure, in generally, was suggested, i.e., the competition between the elastic-energy density stored and the energy density needed for forming one mature shear band in MGs. Our results provide a promising strategy for designing tensile ductile MGs with a pure amorphous structure at room temperature. - Highlights: • Tensile deformation behaviors in multi-layer MG films. • Films with high layer numbers confirmed with a non-localized deformation behavior. • The deformation mode is reasonably controlled by whether U{sub p} larger than U{sub SB.}.

  3. A three-dimensional vertically aligned functionalized multilayer graphene architecture: an approach for graphene-based thermal interfacial materials.

    Science.gov (United States)

    Liang, Qizhen; Yao, Xuxia; Wang, Wei; Liu, Yan; Wong, Ching Ping

    2011-03-22

    Thermally conductive functionalized multilayer graphene sheets (fMGs) are efficiently aligned in large-scale by a vacuum filtration method at room temperature, as evidenced by SEM images and polarized Raman spectroscopy. A remarkably strong anisotropy in properties of aligned fMGs is observed. High electrical (∼386 S cm(-1)) and thermal conductivity (∼112 W m(-1) K(-1) at 25 °C) and ultralow coefficient of thermal expansion (∼-0.71 ppm K(-1)) in the in-plane direction of A-fMGs are obtained without any reduction process. Aligned fMGs are vertically assembled between contacted silicon/silicon surfaces with pure indium as a metallic medium. Thus-constructed three-dimensional vertically aligned fMG thermal interfacial material (VA-fMG TIM) architecture has significantly higher equivalent thermal conductivity (75.5 W m(-1) K(-1)) and lower contact thermal resistance (5.1 mm2 K W(-1)), compared with their counterpart from A-fMGs that are recumbent between silicon surfaces. This finding provides a throughout approach for a graphene-based TIM assembly as well as knowledge of vertically aligned graphene architectures, which may not only facilitate graphene's application in current demanding thermal management but also promote its widespread applications in electrodes of energy storage devices, conductive polymeric composites, etc.

  4. Mars Global Surveyor Ka-Band Frequency Data Analysis

    Science.gov (United States)

    Morabito, D.; Butman, S.; Shambayati, S.

    2000-01-01

    for the feed and electronics equipment. A dichroic plate is used to reflect the X-band energy and pass the Ka-band energy to another mirror. The RF energy for each band is then focused onto a feed horn and low-noise amplifier package. After amplification and RF/IF downconversion, the IF signals are sent to the Experimental Tone Tracker (ETT), a digital phase-lock-loop receiver, which simultaneously tracks both X-band and Ka-band carrier signals. Once a signal is detected, the ETT outputs estimates of the SNR in a I -Hz bandwidth (Pc/No), baseband phase and frequency of the signals every I -sec. Between December 1996 and December 1998, the Ka-band and X-band signals from MGS were tracked on a regular basis using the ETT. The Ka-band downlink frequencies described here were referenced to the spacecraft's on-board USO which was also the X-band frequency reference (fka= 3.8 fx). The ETT estimates of baseband phase at I -second sampled time tags were converted to sky frequency estimates. Frequency residuals were then generated for each band by removing a model frequency from each observable frequency at each time tag. The model included Doppler and other effects derived from spacecraft trajectory files obtained from the MGS Navigation Team. A simple troposphere correction was applied to the data. In addition to residuals, the USO frequencies emitted by the spacecraft were estimated. For several passes, the USO frequencies were determined from X-band data and from Ka-band data (referred to X-band by dividing by 3.8) and were found to be in good agreement. In addition, X-band USO frequency estimates from MGS Radio Science data acquired from operational DSN stations were available for comparison and were found to agree within the I Hz level. The remaining sub-Hertz differences were attributed to the different models and software algorithms used by MGS Radio Science and KaBLE-11. A summary of the results of a linear fit of the USO frequency versus time (day of year) is

  5. Lessons learned from a review of post-accident sampling systems, high range effluent monitors and high concentration particulate iodine samplers

    International Nuclear Information System (INIS)

    Hull, A.P.; Knox, W.H.; White, J.R.

    1987-01-01

    Post-accident sampling systems (PASS), high range gaseous effluent monitors and sampling systems for particulates and iodine in high concentrations have been reviewed at twenty-one licensee sites in Region I of the US Nuclear Regulatory Commission which includes fifteen BWR's and fourteen PWR's. Although most of the installed PASS met the criteria, the highest operational readiness was found in on-line systems that were also used for routine sampling and analysis. The detectors used in the gaseous effluent monitors included external ion chambers, GM tubes, organic scintillators and Cd-Te solid state crystals. Although all were found acceptable, each had its own inherent limitations in the conversion of detector output to the time varying concentration of a post-accident mixture of noble gases. None of the installed particulate and iodine samplers fully met all of the criteria. Their principal limitations included a lack of documentation showing that they could obtain a representative sample and that many of them would collect of an excessive amount of activity at the design criteria. 10 refs., 4 figs., 5 tabs

  6. Smart transactive energy framework in grid-connected multiple home microgrids under independent and coalition operations

    DEFF Research Database (Denmark)

    Marzband, Mousa; Azarinejadian, Fatemeh; Savaghebi, Mehdi

    2018-01-01

    This paper presents a smart Transactive energy (TE) framework in which home microgrids (H-MGs) can collaborate with each other in a multiple H-MG system by forming coalitions for gaining competitiveness in the market. Profit allocation due to coalition between H-MGs is an important issue...

  7. Robust identification of transcriptional regulatory networks using a Gibbs sampler on outlier sum statistic.

    Science.gov (United States)

    Gu, Jinghua; Xuan, Jianhua; Riggins, Rebecca B; Chen, Li; Wang, Yue; Clarke, Robert

    2012-08-01

    Identification of transcriptional regulatory networks (TRNs) is of significant importance in computational biology for cancer research, providing a critical building block to unravel disease pathways. However, existing methods for TRN identification suffer from the inclusion of excessive 'noise' in microarray data and false-positives in binding data, especially when applied to human tumor-derived cell line studies. More robust methods that can counteract the imperfection of data sources are therefore needed for reliable identification of TRNs in this context. In this article, we propose to establish a link between the quality of one target gene to represent its regulator and the uncertainty of its expression to represent other target genes. Specifically, an outlier sum statistic was used to measure the aggregated evidence for regulation events between target genes and their corresponding transcription factors. A Gibbs sampling method was then developed to estimate the marginal distribution of the outlier sum statistic, hence, to uncover underlying regulatory relationships. To evaluate the effectiveness of our proposed method, we compared its performance with that of an existing sampling-based method using both simulation data and yeast cell cycle data. The experimental results show that our method consistently outperforms the competing method in different settings of signal-to-noise ratio and network topology, indicating its robustness for biological applications. Finally, we applied our method to breast cancer cell line data and demonstrated its ability to extract biologically meaningful regulatory modules related to estrogen signaling and action in breast cancer. The Gibbs sampler MATLAB package is freely available at http://www.cbil.ece.vt.edu/software.htm. xuan@vt.edu Supplementary data are available at Bioinformatics online.

  8. Chemistry and Materials Science, 1990--1991. [Second annual report

    Energy Technology Data Exchange (ETDEWEB)

    Sugihara, T.T.; Bruner, J.M.; McElroy, L.A. [eds.

    1991-12-31

    This 2-year (FY 1990-91) contains 49 technical articles in ten sections: research sampler, metals and alloys, energetic materials, chemistry and physics of advanced materials, bonding and reactions at surfaces and interfaces, superconductivity, energy R and D, waste processing and management, characterization and analysis, and facilities and instrumentation. Two more sections list department personnel, their publications etc., consultants, and summary of department budgets. The articles are processed separately for the data base. (DLC)

  9. Local structure and structural signature underlying properties in metallic glasses and supercooled liquids

    Science.gov (United States)

    Ding, Jun

    Metallic glasses (MGs), discovered five decades ago as a newcomer in the family of glasses, are of current interest because of their unique structures and properties. There are also many fundamental materials science issues that remain unresolved for metallic glasses, as well as their predecessor above glass transition temperature, the supercooled liquids. In particular, it is a major challenge to characterize the local structure and unveil the structure-property relationship for these amorphous materials. This thesis presents a systematic study of the local structure of metallic glasses as well as supercooled liquids via classical and ab initio molecular dynamics simulations. Three typical MG models are chosen as representative candidate, Cu64 Zr36, Pd82Si18 and Mg65Cu 25Y10 systems, while the former is dominant with full icosahedra short-range order and the prism-type short-range order dominate for latter two. Furthermore, we move to unravel the underlying structural signature among several properties in metallic glasses. Firstly, the temperature dependence of specific heat and liquid fragility between Cu-Zr and Mg-Cu-Y (also Pd-Si) in supercooled liquids are quite distinct: gradual versus fast evolution of specific heat and viscosity/relaxation time with undercooling. Their local structural ordering are found to relate with the temperature dependence of specific heat and relaxation time. Then elastic heterogeneity has been studied to correlate with local structure in Cu-Zr MGs. Specifically, this part covers how the degree of elastic deformation correlates with the internal structure at the atomic level, how to quantitatively evaluate the local solidity/liquidity in MGs and how the network of interpenetrating connection of icosahedra determine the corresponding shear modulus. Finally, we have illustrated the structure signature of quasi-localized low-frequency vibrational normal modes, which resides the intriguing vibrational properties in MGs. Specifically, the

  10. Information Science: Science or Social Science?

    OpenAIRE

    Sreeramana Aithal; Paul P.K.,; Bhuimali A.

    2017-01-01

    Collection, selection, processing, management, and dissemination of information are the main and ultimate role of Information Science and similar studies such as Information Studies, Information Management, Library Science, and Communication Science and so on. However, Information Science deals with some different characteristics than these subjects. Information Science is most interdisciplinary Science combines with so many knowledge clusters and domains. Information Science is a broad disci...

  11. Application of Polar Organic Chemical Integrative Sampler (POCIS) to monitor emerging contaminants in tropical waters.

    Science.gov (United States)

    Bayen, Stéphane; Segovia, Elvagris; Loh, Lay Leng; Burger, David F; Eikaas, Hans S; Kelly, Barry C

    2014-06-01

    Tools specifically validated for tropical environments are needed to accurately describe the behavior of chemical contaminants in tropical ecosystems. In the present study, sampling rates (Rs) were determined for the commercial pharmaceutical-type Polar Organic Chemical Integrative Sampler (POCIS) with a 45.8cm(2) exposure surface for 35 Pharmaceutically Active Compounds (PhACs) and Endocrine Disrupting Compounds (EDCs), of which eight compounds (albuterol, atorvastatin, diltiazem, dilantin, enalapril, norfluoxetine, risperidone and warfarin) were reported for the first time. These sampling rates were measured in an outdoor laboratory calibration setup to best capture diurnal tropical temperature variations (29±3°C). The effect of stirring and salinity was investigated. For all compounds, the sampling rates were higher under stirred conditions as compared to quiescent conditions. Calibration results in the presence of 30g sodium chloride support that the effects of salinity on POCIS sampling rates are compound-specific. Comparisons between Time-Weight Average (TWA) water concentrations using POCIS and spot sample levels in the field (2 lake and 1 mangrove estuary sites) are presented. Results showed that POCIS TWA concentrations were in agreement with spot sample concentrations for these aquatic systems. Results indicate that POCIS can be used to effectively measure the TWA concentration for a range of PhACs and EDCs in tropical waters. However, based on the results from mass balance and field deployments, POCIS did not appear suitable for compounds with a low mass balance recovery during calibration (e.g. triclosan and linuron in this study). Copyright © 2014 Elsevier B.V. All rights reserved.

  12. Application of Rhizon Porewater Samplers to Shipboard Operations, IODP Expedition 308, Northeast Gulf of Mexico

    Science.gov (United States)

    Gilhooly, W. P.; Macko, S. A.; Flemings, P. B.

    2005-12-01

    Pleistocene and Recent sediments within the Brazos-Trinity and Ursa Basins (northwestern Gulf of Mexico) were largely deposited by turbidity currents and have been deformed by a number of mass transport events. The geochemical composition of interstitial waters was determined in order to assess fluid flow within these sediments. Typical porewater sampling resolution, using advanced piston coring and the traditional Manheim squeezer technique, is approximately one sample every other core (20m) with the highest working resolution at one sample every 1.5m. In this study, Rhizon soil moisture samplers were used to attain high-resolution porewater profiles within sea floor surface sediments and for permeable sediments at depth. The small dimensions (2mm x 30mm) and pore-size (1μm) of the devices enable high-frequency placement within a core, specific targeting of the sequence of interest, and do not require sediment removal from the core, or filtering of extracted porewaters. Initial shipboard analyses derived from sediments at the Ursa Basin (Site 1322) indicate a linear decrease in salinity with depth at U1322 where the overpressure gradient is thought to be greatest. The less saline waters with depth lends evidence for potential mixing between deep-seated fluids and low salinity ones derived from the Blue Unit and seawater. Isotopic composition and concentrations of sulfur species (SO4 and H2S) dissolved in porewaters, as well as, ionic compositions (Cl, Na, K, Ca, Mg) and chemical composition of associated sediments (%C, %N, 13C, and 15N) are compared with chemical results obtained with squeezers.

  13. A Multicenter Phase I/II Study of the BCNU Implant (Gliadel ® Wafer) for Japanese Patients with Malignant Gliomas

    Science.gov (United States)

    AOKI, Tomokazu; NISHIKAWA, Ryo; SUGIYAMA, Kazuhiko; NONOGUCHI, Naosuke; KAWABATA, Noriyuki; MISHIMA, Kazuhiko; ADACHI, Jun-ichi; KURISU, Kaoru; YAMASAKI, Fumiyuki; TOMINAGA, Teiji; KUMABE, Toshihiro; UEKI, Keisuke; HIGUCHI, Fumi; YAMAMOTO, Tetsuya; ISHIKAWA, Eiichi; TAKESHIMA, Hideo; YAMASHITA, Shinji; ARITA, Kazunori; HIRANO, Hirofumi; YAMADA, Shinobu; MATSUTANI, Masao

    2014-01-01

    Carmustine (BCNU) implants (Gliadel® Wafer, Eisai Inc., New Jersey, USA) for the treatment of malignant gliomas (MGs) were shown to enhance overall survival in comparison to placebo in controlled clinical trials in the United States and Europe. A prospective, multicenter phase I/II study involving Japanese patients with MGs was performed to evaluate the efficacy, safety, and pharmacokinetics of BCNU implants. The study enrolled 16 patients with newly diagnosed MGs and 8 patients with recurrent MGs. After the insertion of BCNU implants (8 sheets maximum, 61.6 mg BCNU) into the removal cavity, various chemotherapies (including temozolomide) and radiotherapies were applied. After placement, overall and progression-free survival rates and whole blood BCNU levels were evaluated. In patients with newly diagnosed MGs, the overall survival rates at 12 months and 24 months were 100.0% and 68.8%, and the progression-free survival rate at 12 months was 62.5%. In patients with recurrent MGs, the progression-free survival rate at 6 months was 37.5%. There were no grade 4 or higher adverse events noted due to BCNU implants, and grade 3 events were observed in 5 of 24 patients (20.8%). Whole blood BCNU levels reached a peak of 19.4 ng/mL approximately 3 hours after insertion, which was lower than 1/600 of the peak BCNU level recorded after intravenous injections. These levels decreased to less than the detection limit (2.00 ng/mL) after 24 hours. The results of this study involving Japanese patients are comparable to those of previous studies in the United States and Europe. PMID:24739422

  14. Sequential Isolation of Saturated, Aromatic, Resinic and Asphaltic Fractions Degrading Bacteria from Oil Contaminated Soil in South Sumatera

    Directory of Open Access Journals (Sweden)

    Pingkan Aditiawati

    2012-04-01

    Full Text Available Sequential isolation has been conducted to obtain isolates of saturated, aromatic, resin, and asphaltene fractions degrading bacteria from oil contaminated sites. Five soil samples were collected from South Sumatera. These were analyzed using soil extract medium enriched with oil recovery or Remaining-Oil recovery Degradated (ROD as sole carbon and energy sources according to the isolation stage. ROD at the end of every isolation stage analyzed oil fractions by use of the SARA analysis method. Six isolates of bacteria have been selected, one isolate was fraction saturates degrading bacteria that are Mycobacterium sp. T1H2D4-7 at degradation rate 0.0199 mgs/h with density 8.4x106 cfu/g from stage I. The isolate T2H1D2-4, identified as Pseudomonas sp. was fraction aromatics degrading bacteria at accelerate 0.0141 mgs/h with density 5.1x106 cfu/g are obtained at stage II. Two isolates namely Micrococcus sp. T3H2D4-2 and Pseudomonas sp. T1H1D5-5 were fraction resins degrading bacteria by accelerate 0.0088 mgs/h at density 5.6x106 cfu/g and 0.0089 mgs/h at density 5.7x106 cfu/g are obtained at stage III. Isolation of stage IV has been obtained two isolates Pseudomonas sp. T4H1D3-1and Pseudomonas sp. T4H3D5-4 were fraction asphaltenes degrading bacteria by accelerate 0.0057 mgs/h at density 5.6x106 cfu/g and accelerate 0.0058 mgs/h at density 5.7x106 cfu/g.

  15. Effects of clove oil-phospholipid mixtures on rheology of gum tragacanth - possible application for surfactant action on mucus gel simulants.

    Science.gov (United States)

    Banerjee, R; Puniyani, R R

    2000-01-01

    The present study evaluates the effectiveness of specialised biomaterials consisting of clove oil- phospholipid mixtures as possible substitute surfactants in diseases of altered mucus viscosity by studying their effect on the viscosity of mucus gel simulants in vitro. Test surfactants consisting of phospholipid-clove oil mixtures in the ratio of 1 part of oil to 9 parts of phospholipid were prepared. The phospholipids used were dipalmitoyl phosphatidylcholine (PC), phosphatidylethanolamine (PE) and phosphatidylglycerol (PG) and binary mixtures of PC: PE and PC: PG in the ratio of 2 parts of PC to 3 parts of PE or PG. The effects of the phospholipid-clove oil mixtures on the viscosity of mucus gel simulant (MGS: a polymeric gel consisting predominantly of gum tragacanth and simulating respiratory mucus), was studied by application of steady shear rates ranging from 0.512 to 51.2/s in a concentric cylinder viscometer at 37 degrees C. The change in MGS viscosity, after incubation with surfactants, was found to have a non-Newtonian character and to follow the power law model with R2 values >0.8. The addition of clove oil-phospholipid mixtures caused a decrease in the MGS viscosity when compared with the effect of the phospholipid alone at low shear rates in case of PC, PG and PCPG. The combination of PC : PG with clove oil caused ratios of change in MGS viscosity < 1 i.e., caused a decrease in the MGS viscosity. PC: PG with clove oil was capable of lowering MGS viscosity and should be further researched as possible therapies for diseases of altered mucus rheology.

  16. A fast dynamic mode in rare earth based glasses

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, L. Z.; Xue, R. J.; Zhu, Z. G.; Wang, W. H.; Bai, H. Y., E-mail: hybai@iphy.ac.cn [Institute of Physics, Chinese Academy of Sciences, Beijing 100190 (China); Ngai, K. L. [Dipartimento di Fisica, Università di Pisa, Largo B. Pontecorvo 3, I-56127 Pisa (Italy)

    2016-05-28

    Metallic glasses (MGs) usually exhibit only slow β-relaxation peak, and the signature of the fast dynamic is challenging to be observed experimentally in MGs. We report a general and unusual fast dynamic mode in a series of rare earth based MGs manifested as a distinct fast β′-relaxation peak in addition to slow β-relaxation and α-relaxation peaks. We show that the activation energy of the fast β′-relaxation is about 12RT{sub g} and is equivalent to the activation of localized flow event. The coupling of these dynamic processes as well as their relationship with glass transition and structural heterogeneity is discussed.

  17. Pharmaceuticals, alkylphenols and pesticides in Mediterranean coastal waters: Results from a pilot survey using passive samplers

    Science.gov (United States)

    Munaron, Dominique; Tapie, Nathalie; Budzinski, Hélène; Andral, Bruno; Gonzalez, Jean-Louis

    2012-12-01

    21 pharmaceuticals, 6 alkylphenols and 27 hydrophilic pesticides and biocides were investigated using polar organic contaminant integrative samplers (POCIS) during a large-scale study of contamination of French Mediterranean coastal waters. Marine and transitional water-bodies, defined under the EU Water Framework Directive were monitored. Our results show that the French Mediterranean coastal waters were contaminated with a large range of emerging contaminants, detected at low concentrations during the summer season. Caffeine, carbamazepine, theophilline and terbutaline were detected with a detection frequency higher than 83% in the coastal waters sampled, 4-nonylphenol (4-NP), 4-tert-octylphenol (4-OP) and 4-nonylphenol diethoxylate (NP2EO) were detected in all coastal waters sampled, and diuron, terbuthylazine, atrazine, irgarol and simazine were detected in more than 77% of samples. For pharmaceuticals, highest time-weighted average (TWA) concentrations were measured for caffeine and carbamazepine (32 and 12 ng L-1, respectively). For alkylphenols, highest TWA concentrations were measured for 4-nonylphenol mono-ethoxylate and 4-nonylphenol (41 and 33 ng L-1, respectively), and for herbicides and biocides, they were measured for diuron and irgarol (33 and 2.5 ng L-1, respectively). Except for Diana lagoon, lagoons and semi-enclosed bays were the most contaminated areas for herbicides and pharmaceuticals, whilst, for alkylphenols, levels of contamination were similar in lagoons and coastal waters. This study demonstrates the relevance and utility of POCIS as quantitative tool for measuring low concentrations of emerging contaminants in marine waters.

  18. Study of the superficial ozone concentrations in the atmosphere of Comunidad de Madrid using passive samplers

    Directory of Open Access Journals (Sweden)

    D. Galán Madruga

    2001-06-01

    Full Text Available The ozone is a secondary atmospheric pollutant which is generated for photochemical reactions of volatil organic compounds (VOC’s and nitrogen oxides (NOx. In Spain the ozone is a big problem as a consequence of the solar radiation to reach high levels. Exposure over a period of time to elevated ozone concentrations can cause damage in the public health and alterations in the vegetation.The aim of this study is to carry out the development and validation of a measurement method to let asses the superficial ozone levels in the Comunidad de Madrid, by identifing the zones more significants, where to measure with UV photometric monitors (automatics methods this pollutant and where the health and the vegetation can be affected. To such effect, passive samplers are used, which have glass fiber filters coated with a solution of sodium nitrite, potassium carbonate, glycerol and water. The nitrite ion in the presence of ozone is oxidized to nitrato ion, which it is extrated with ultrapure water and analyzed for ion chromatography, by seen proportional to the concentration existing in the sampling point.The results of validation from field tests indicate a excellent correlation between the passive and the automatic method.The higher superficial ozone concentrations are placed in rural zones, distanced of emission focus of primary pollutants (nitrogen oxides and volatil organic compounds... principally in direction soutwest and northwest of the Comunidad of Madrid.

  19. Calibration and field evaluation of polar organic chemical integrative sampler (POCIS) for monitoring pharmaceuticals in hospital wastewater

    International Nuclear Information System (INIS)

    Bailly, Emilie; Levi, Yves; Karolak, Sara

    2013-01-01

    The Polar Organic Chemical Integrative Sampler (POCIS) is a new tool for the sampling of organic pollutants in water. We tested this device for the monitoring of pharmaceuticals in hospital wastewater. After calibration, a field application was carried out in a French hospital for six pharmaceutical compounds (Atenolol, Prednisolone, Methylprednisolone, Sulfamethoxazole, Ofloxacin, Ketoprofen). POCIS were calibrated in tap water and wastewater in laboratory conditions close to relevant environmental conditions (temperature, flow velocity). Sampling rates (R s ) were determined and we observed a significant increase with flow velocity and temperature. Whatever the compound, the R s value was lower in wastewater and the linear phase of uptake was shorter. POCIS were deployed in a hospital sewage pipe during four days and the estimated water concentrations were close to those obtained with twenty-four hour composite samples. -- Highlights: ► Calibration of POCIS for the monitoring of pharmaceuticals in hospital wastewater. ► Uptake profile presents a shorter linear phase in wastewater than in tap water. ► Influence of R s values by temperature, flow velocity and bio-fouling. ► Correlation between concentrations estimated from POCIS or measured in TWA samples. ► Deployment period should be no longer than five days. -- After calibration in tap water and hospital wastewater, POCIS were used to monitor pharmaceuticals in hospital sewage and were compared to TWA sampling

  20. A Three-Stage Optimal Approach for Power System Economic Dispatch Considering Microgrids

    Directory of Open Access Journals (Sweden)

    Wei-Tzer Huang

    2016-11-01

    Full Text Available The inclusion of microgrids (MGs in power systems, especially distribution-substation-level MGs, significantly affects power systems because of the large volumes of import and export power flows. Consequently, power dispatch has become complicated, and finding an optimal solution is difficult. In this study, a three-stage optimal power dispatch model is proposed to solve such dispatch problems. In the proposed model, the entire power system is divided into two parts, namely, the main power grid and MGs. The optimal power dispatch problem is resolved on the basis of multi-area concepts. In stage I, the main power system economic dispatch (ED problem is solved by sensitive factors. In stage II, the optimal power dispatches of the local MGs are addressed via an improved direct search method. In stage III, the incremental linear models for the entire power system can be established on the basis of the solutions of the previous two stages and can be subjected to linear programming to determine the optimal reschedules from the original dispatch solutions. The proposed method is coded using Matlab and tested by utilizing an IEEE 14-bus test system to verify its feasibility and accuracy. Results demonstrated that the proposed approach can be used for the ED of power systems with MGs as virtual power plants.

  1. Comparative transcriptome analysis on the synthesis pathway of honey bee (Apis mellifera) mandibular gland secretions.

    Science.gov (United States)

    Wu, YuQi; Zheng, HuoQing; Corona, Miguel; Pirk, Christian; Meng, Fei; Zheng, YuFei; Hu, FuLiang

    2017-07-03

    Secretions from mandibular glands (MGs) have important caste-specific functions that are associated with the social evolution of honey bees. To gain insights into the molecular architecture underlying these caste differences, we compared the gene expression patterns of MGs from queens, queenright workers (WQRs) and queenless workers (WQLs) using high-throughput RNA-sequencing technology. In total, we identified 46 candidate genes associated with caste-specific biosynthesis of fatty acid pheromones in the MG, including members of cytochrome P450 (CYP450) family and genes involved in fatty acid β-oxidation and ω-oxidation. For further identification of the CYP450s genes involved in the biosynthesis of MG secretions, we analyzed by means of qPCR, the expression levels of six of the CYP450 genes most abundantly expressed in the transcriptome analysis across different castes, ages, tasks and tissues. Our analysis revealed that CYP6AS8 and CYP6AS11, the most abundantly expressed CYP450 genes in worker and queen MGs, respectively, are selectively expressed in the MGs of workers and queens compared to other tissues. These results suggest that these genes might be responsible for the critical bifurcated hydroxylation process in the biosynthesis pathway. Our study contributes to the description of the molecular basis for the biosynthesis of fatty acid-derived pheromones in the MGs.

  2. Passive air sampler as a tool for long-term air pollution monitoring: Part 1. Performance assessment for seasonal and spatial variations

    International Nuclear Information System (INIS)

    Klanova, Jana; Kohoutek, Jiri; Hamplova, Lenka; Urbanova, Petra; Holoubek, Ivan

    2006-01-01

    The potential of passive air sampling devices (polyurethane foam disks) to assess the influence of local sources on the quality of the surrounding environment was investigated. DEZA Valasske Mezirici, a coal tar and mixed tar oils processing plant, and Spolana Neratovice, a chemical factory with the history of high production of organochlorinated pesticides (OCPs), were selected as the point sources of PAHs, and OCPs, respectively. Levels of PCBs, OCPs and PAHs were determined for all sampling sites and sampling periods. The study brought useful data about the air concentrations of POPs in the investigated regions. More important, it provided information on the transport and fate of POPs in the vicinity of local sources of contamination useful for the estimation of their influence. Very good capability of passive samplers to reflect temporal and spatial fluctuation in concentrations of persistent organic pollutants in the ambient air was confirmed which makes them applicable for monitoring on the local scale. - Passive air sampling techniques can indicate seasonal and spatial variations in the ambient concentrations of persistent organic compounds near point sources

  3. Mass gatherings: A one-stop opportunity to complement global disease surveillance

    Directory of Open Access Journals (Sweden)

    Habida Elachola

    2016-01-01

    Full Text Available Emerging infections including those resulting from the bioterrorist use of infectious agents have indicated the need for global health surveillance. This paper reviews multiple surveillance opportunities presented by mass gatherings (MGs that align with fundamental questions in epidemiology (why, what, who, where, when and how. Some MGs bring together large, diverse population groups coming from countries with high prevalence of communicable diseases and disparate surveillance capacities. MGs have the potential to exacerbate the transmission dynamics of infectious diseases due to various factors including the high population density and rigor of events, increase in number of people with underlying diseases that predisposes them to disease acquisition, mixing of people from countries or regions with and without efficient disease control efforts, and varying endemicity or existence of communicable diseases in home countries. MGs also have the potential to increase the opportunities for mechanical and even heat-related injuries, morbidity or deaths from accidents, alcohol use, deliberate terrorist attacks with biological agents and/or with explosives and from exacerbation of pre-existing conditions. Responding to these wider range of events may require the use of novel bio-surveillance systems designed to collect data from different sources including electronic and non-electronic medical records from emergency departments and hospitalisations, laboratories, medical examiners, emergency call centres, veterinary, food processors, drinking water systems and even other non-traditional sources such as over-the-counter drug sales and crowd photographs. Well-structured, interoperable real-time surveillance and reporting systems should be integral to MG planning. The increase in magnitude of participants exceeding millions and diversity of people attending MGs can be proactively used to conduct active surveillance of communicable and non

  4. Meier-Gorlin syndrome.

    Science.gov (United States)

    de Munnik, Sonja A; Hoefsloot, Elisabeth H; Roukema, Jolt; Schoots, Jeroen; Knoers, Nine V A M; Brunner, Han G; Jackson, Andrew P; Bongers, Ernie M H F

    2015-09-17

    Meier-Gorlin syndrome (MGS) is a rare autosomal recessive primordial dwarfism disorder, characterized by microtia, patellar applasia/hypoplasia, and a proportionate short stature. Associated clinical features encompass feeding problems, congenital pulmonary emphysema, mammary hypoplasia in females and urogenital anomalies, such as cryptorchidism and hypoplastic labia minora and majora. Typical facial characteristics during childhood comprise a small mouth with full lips and micro-retrognathia. During ageing, a narrow, convex nose becomes more prominent. The diagnosis MGS should be considered in patients with at least two of the three features of the clinical triad of microtia, patellar anomalies, and pre- and postnatal growth retardation. In patients with short stature and/or microtia, the patellae should be assessed with care by ultrasonography before age 6 or radiography thereafter. Mutations in one of five genes (ORC1, ORC4, ORC6, CDT1, and CDC6) of the pre-replication complex, involved in DNA-replication, are detected in approximately 67-78% of patients with MGS. Patients with ORC1 and ORC4 mutations appear to have the most severe short stature and microcephaly. Management should be directed towards in-depth investigation, treatment and prevention of associated problems, such as growth retardation, feeding problems, hearing loss, luxating patellae, knee pain, gonarthrosis, and possible pulmonary complications due to congenital pulmonary emphysema with or without broncho- or laryngomalacia. Growth hormone treatment is ineffective in most patients with MGS, but may be effective in patients in whom growth continues to decrease after the first year of life (usually growth velocity normalizes after the first year) and with low levels of IGF1. At present, few data is available about reproduction of females with MGS, but the risk of premature labor might be increased. Here, we propose experience-based guidelines for the regular care and treatment of MGS patients.

  5. Origin of Shear Stability and Compressive Ductility Enhancement of Metallic Glasses by Metal Coating

    Science.gov (United States)

    Sun, B. A.; Chen, S. H.; Lu, Y. M.; Zhu, Z. G.; Zhao, Y. L.; Yang, Y.; Chan, K. C.; Liu, C. T.

    2016-01-01

    Metallic glasses (MGs) are notorious for the poor macroscopic ductility and to overcome the weakness various intrinsic and extrinsic strategies have been proposed in past decades. Among them, the metal coating is regarded as a flexible and facile approach, yet the physical origin is poorly understood due to the complex nature of shear banding process. Here, we studied the origin of ductile enhancement in the Cu-coating both experimentally and theoretically. By examining serrated shear events and their stability of MGs, we revealed that the thin coating layer plays a key role in stopping the final catastrophic failure of MGs by slowing down shear band dynamics and thus retarding its attainment to a critical instable state. The mechanical analysis on interplay between the coating layer and shear banding process showed the enhanced shear stability mainly comes from the lateral tension of coating layer induced by the surface shear step and the bonding between the coating layer and MGs rather than the layer thickness is found to play a key role in contributing to the shear stability. PMID:27271435

  6. A Novel Decentralized Economic Operation in Islanded AC Microgrids

    Directory of Open Access Journals (Sweden)

    Hua Han

    2017-06-01

    Full Text Available Droop schemes are usually applied to the control of distributed generators (DGs in microgrids (MGs to realize proportional power sharing. The objective might, however, not suit MGs well for economic reasons. Addressing that issue, this paper proposes an alternative droop scheme for reducing the total active generation costs (TAGC. Optimal economic operation, DGs’ capacity limitations and system stability are fully considered basing on DGs’ generation costs. The proposed scheme utilizes the frequency as a carrier to realize the decentralized economic operation of MGs without communication links. Moreover, a fitting method is applied to balance DGs’ synchronous operation and economy. The effectiveness and performance of the proposed scheme are verified through simulations and experiments.

  7. Comparison of forced expiratory spirometric flow changes following ...

    African Journals Online (AJOL)

    Group B received intrathecal anaesthesia 15 mgs of bupivacaine with 0.5 ml of normal saline and Group BF received 15 mgs of bupivacaine with 0.5 ml of fentanyl (25 μg) intrathecally. The patients were instructed about the performance of the spirometry on the previous evening of the surgery. Forced vital capacity, forced ...

  8. Polyoxymethylene passive samplers to assess the effectiveness of biochar by reducing the content of freely dissolved fipronil and ethiprole.

    Science.gov (United States)

    Li, Shasha; Wang, Pingping; Liu, Xingang; Wu, Xiaohu; Dong, Fengshou; Xu, Jun; Zheng, Yongquan

    2018-07-15

    An equilibrium passive sampler based on polyoxymethylene (POM) was used to determine the freely dissolved concentrations (C free ) of fipronil and ethiprole. The sorption equilibrium times of fipronil and ethiprole in POM were 14.2d and 24.0d, respectively. The POM-water partitioning coefficients (logK POM-water ) were 2.6 for fipronil and 1.4 for ethiprole. The method was further used to evaluate the sorption behavior of biochars which produced by pyrolysis of Magnolia wood (Magnolia denudata) at 300°C, 500°C and 700°C. The amounts of target compounds adsorbed increased with increasing pyrolysis temperature of the biochars. Biochars characterized by a low polarity index had better sorption capacity for the target compounds. The additions of biochars to sediment were effective in reducing C free , and the enhancement was found to be more pronounced with high biochar content. C free in sediment with more organic matter was significantly higher after biochar addition. Increasing the sediment-biochar contact time from 7 to 30d resulted in an increase in sorption of the compounds. We conclude that Magnolia wood biochar effectively reduces the content of freely dissolved fipronil and ethiprole content in sediment. Copyright © 2018. Published by Elsevier B.V.

  9. Clustering, microalloying and mechanical properties in Cu/Zr-based glassy models by molecular dynamics simulations and ab-initio computations

    Energy Technology Data Exchange (ETDEWEB)

    Lekka, Ch.E.; Bokas, G.B. [University of Ioannina, Department of Materials Science and Engineering, Ioannina 45100 (Greece); Almyras, G.A. [University of Ioannina, Department of Physics, Ioannina 45110 (Greece); Papageorgiou, D.G. [University of Ioannina, Department of Materials Science and Engineering, Ioannina 45100 (Greece); Evangelakis, G.A., E-mail: gevagel@cc.uoi.gr [University of Ioannina, Department of Physics, Ioannina 45110 (Greece)

    2012-09-25

    Highlights: Black-Right-Pointing-Pointer Cu-Zr MGs consist of interpenetrating ICO-like clusters (superclusters (SCs)). Black-Right-Pointing-Pointer The SCs participate in the accommodation of the tensile deformation. Black-Right-Pointing-Pointer The SCs may exhibit a free of bonds (FoB) plane. Black-Right-Pointing-Pointer Al microalloying changes the SCs' electronic structure inducing FoB planes. Black-Right-Pointing-Pointer Control of SCs' electronic structure may lead to control of MGs' properties. - Abstract: We present results on the microstructure of Cu-Zr metallic glasses (MGs) at equilibrium and under tensile deformation by means of large scale molecular dynamics (MD) simulations and density functional theory (DFT) calculations. We found that the MGs are composed by interpenetrating icosahedral-like (ICO) clusters forming superclusters (SCs). The deformation accommodation is associated with the destruction and recreation of these ICO clusters and SCs. DFT calculations on the Cu{sub 13}Zr{sub 10} SCs with Cu-Cu core atoms revealed the presence of a free of bonds (FoB) plane that could be viewed as analog of a slip plane of the crystalline materials. The microalloying (MA) effect in a similar SC (one of the core atoms substituted by Al) yielded that Al is associated with the formation of a FoB plane. These results provide possible explanations of the experimental findings referring to the short range order, the MA effect and could potentially be used for the design of new MGs.

  10. Meckel Gruber syndrome, A case report

    Science.gov (United States)

    Aslan, Kiper; Külahçı Aslan, Elif; Orhan, Adnan; Atalay, Mehmet Aral

    2015-01-01

    ABSTRACT. Introduction: Meckel-Gruber Syndrome was first described by J R Meckel in 1822. It is an autosomal recessive disorder, and is caused by the failure of mesodermal induction. The typical triad of Meckel-Gruber Syndrome (MGS) involves meningo-encephalocele, polycystic kidneys and postaxial polydactyly. The worldwide incidence varies from 1 in 1.300 to 1 in 140.000 live births. Case: In this report, we present a case of MGS in which the diagnosis was made at 19 weeks of gestation based on ultrasonographic findings of the typical triad of the disease (encephalocele, polycystic kidneys, and polydactyly) These features were suggestive of the diagnosis of Meckel Gruber Syndrome (MGS). She had also placenta previa totalis. The patient was counselled regarding the lethal outcome of MGS. Unfortunately, the family did not approve the termination of pregnancy. At the 32nd week, she referred to hospital with complaints of vaginal bleeding and uterine contractions. An emergency cesarean section was perfomed due to plasental malposition. A 1380 gr, female fetus was delivered. First and 5th minute Apgar scores were 1 and 0, respectively. Consequently, the baby died after 45 minutes of neonatal resuscitation. Conclusıon: MGS is a lethal disorder. One cannot speak about survival of the fetus because of the pulmonary hypoplasia. The parents should be counseled about prognosis of the fetus and the outcome. Counselers should strictly give information about the recurrence risk for the next pregnancies. PMID:26037304

  11. Correlation between relaxations and plastic deformation, and elastic model of flow in metallic glasses and glass-forming liquids

    International Nuclear Information System (INIS)

    Wang Weihua

    2011-01-01

    We study the similarity and correlations between relaxations and plastic deformation in metallic glasses (MGs) and MG-forming liquids. It is shown that the microscope plastic events, the initiation and formation of shear bands, and the mechanical yield in MGs where the atomic sites are topologically unstable induced by applied stress, can be treated as the glass to supercooled liquid state transition induced by external shear stress. On the other hand, the glass transition, the primary and secondary relaxations, plastic deformation and yield can be attributed to the free volume increase induced flow, and the flow can be modeled as the activated hopping between the inherent states in the potential energy landscape. We then propose an extended elastic model to describe the flow based on the energy landscape theory. That is, the flow activation energy density is linear proportional to the instantaneous elastic moduli, and the activation energy density ρ E is determined to be a simple expression of ρ E =(10/11)G+(1/11)K. The model indicates that both shear and bulk moduli are critical parameters accounting for both the homogeneous and inhomogeneous flows in MGs and MG-forming liquids. The elastic model is experimentally certified. We show that the elastic perspectives offers a simple scenario for the flow in MGs and MG-forming liquids and are suggestive for understanding the glass transition, plastic deformation, and nature and characteristics of MGs

  12. The Association between Intermodal (PM1-2.5) and PM1, PM2.5, Coarse Fraction and Meteorological Parameters in Various Environments in Central Europe.

    Czech Academy of Sciences Publication Activity Database

    Kozáková, Jana; Pokorná, P.; Černíková, A.; Hovorka, J.; Braniš, M.; Moravec, Pavel; Schwarz, Jaroslav

    2017-01-01

    Roč. 17, č. 5 (2017), s. 1234-1243 ISSN 1680-8584 R&D Projects: GA ČR(CZ) GBP503/12/G147 Institutional support: RVO:67985858 Keywords : intermodal fraction * personal cascade impactor sampler * PMx Subject RIV: DI - Air Pollution ; Quality OBOR OECD: Environmental sciences (social aspects to be 5.7) Impact factor: 2.606, year: 2016

  13. Comparison of Physical Properties of Marine and Arctic Gas-Hydrate-Bearing Deposits

    Science.gov (United States)

    Winters, W. J.; Walker, M.; Collett, T. S.; Bryant, S. L.; Novosel, I.; Wilcox-Cline, R.; Bing, J.; Gomes, M. L.

    2009-12-01

    Gas hydrate (GH) occurs in both marine settings and in arctic environments within a wide variety of sediment types. Grain-size analyses from both environments indicate that intrinsic host-sediment properties have a strong influence on gas-hydrate distribution and morphologic characteristics. Depending on the amount formed or dissociated, gas hydrate can significantly change in situ sediment acoustic, mechanical, and hydraulic properties. The U.S. Geological Survey, in cooperation with the U.S. Dept. of Energy, BP Expl.-Alaska, Nat. GH Prog. of India, Canadian Geological Survey, Int. Ocean Drilling Program, Japan Oil Gas and Metals Nat. Corp., Japan Pet. Expl. Co., Int. Marine Past Global Changes Study (IMAGES) program, and Paleoceanography of the Atlantic and Geochemistry (PAGE) program, determined physical properties from marine and arctic sediments and their relation to the presence of GH. At two arctic sites, the Mount Elbert well on the Alaskan North Slope and the Mallik wells on the Mackenzie Delta, NWT, >10-m thick gas-hydrate-bearing (GHB) sandy deposits are capped by finer-grained sediments that may reduce gas migration. In the Mount Elbert well, average median grain sizes (MGS) for the two thickest GHB deposits are 65 and 60 µm. Finer-grained (average MGS of 9 and 28 µm) sediments have plug permeabilities that are 300 and 14 times smaller than underlying GHB sediment. Average MGS of GHB sediment from the Mallik 2L well is ~ 111 µm, compared to overlying sediment with an average MGS of ~ 32 µm. Gas hydrate morphology in the Gulf of Mexico (GOM) and offshore India is substantially more complex than in the arctic, and is related to pervasive, although not exclusive, finer-grained deposits. Massive, several-cm thick, GH layers were recovered in piston cores in the northern GOM, in sediment with little visible lithologic variability (average MGS ~ 0.8 µm). In wells off the east coast of India, GH was present in sand-rich, fractured clay, and reservoirs

  14. Utopia Cracks and Polygons

    Science.gov (United States)

    2003-01-01

    MGS MOC Release No. MOC2-339, 23 April 2003This Mars Global Surveyor (MGS) Mars Orbiter Camera (MOC) image shows a pattern of polygonal cracks and aligned, elliptical pits in western Utopia Planitia. The picture covers an area about 3 km (about 1.9 mi) wide near 44.9oN, 274.7oW. Sunlight illuminates the scene from the left.

  15. An optimal autonomous microgrid cluster based on distributed generation droop parameter optimization and renewable energy sources using an improved grey wolf optimizer

    Science.gov (United States)

    Moazami Goodarzi, Hamed; Kazemi, Mohammad Hosein

    2018-05-01

    Microgrid (MG) clustering is regarded as an important driver in improving the robustness of MGs. However, little research has been conducted on providing appropriate MG clustering. This article addresses this shortfall. It proposes a novel multi-objective optimization approach for finding optimal clustering of autonomous MGs by focusing on variables such as distributed generation (DG) droop parameters, the location and capacity of DG units, renewable energy sources, capacitors and powerline transmission. Power losses are minimized and voltage stability is improved while virtual cut-set lines with minimum power transmission for clustering MGs are obtained. A novel chaotic grey wolf optimizer (CGWO) algorithm is applied to solve the proposed multi-objective problem. The performance of the approach is evaluated by utilizing a 69-bus MG in several scenarios.

  16. New Equipment and Techniques for Remote Sampling of Stored Radioactive Waste

    International Nuclear Information System (INIS)

    Nance, T.A.

    2001-01-01

    Radioactive waste is stored at the Savannah River Site (SRS), part of the Department of Energy (DOE) complex. This radioactive waste is stored in buried tanks and management of the waste requires several processes, including material addition, heating, cooling, mixing, and transfer from tank to tank. During waste processing, it is necessary to know the chemical components and their characteristics to determine the steps necessary to maintain the waste form or to manipulate the waste into the form desired. Waste characterization begins by obtaining a sample for analysis. High level radioactive waste sampling is routinely done with simple, standard samplers such as a dip sample. Other sampling is non-routine or specialized, with unique, special requirements, such as sampling remote areas that are difficult to reach. Other specialized sampling includes sampling materials with unknown characteristics or material that must be gathered to obtain an adequate sample or materials that must be broken up to sample or forcibly separated from the tank. The samplers described in this paper are specialized samplers. These samplers include the Dip Filter Sampler, Soft Core Sampler, Hard Core Sampler, Circle Scrape Sampler, Small Scrape Sampler, Suction and Strain Sampler, and Vial Snapper Sampler. The Dip Filter Sampler is used to sample floating particulate matter or floating organic matter. The Soft Core Sampler and Hard Core Sampler are used to obtain samples of solids from the tank floor. The Soft Core Sampler is used on soft solids such as sludge and saltcake and the Hard Core Sampler on hardened solid deposits. The Circle Scrape Sampler is used to obtain solid samples through a small entry riser and out from under the riser. The Small Scrape Sampler enters a small entry riser and is used to scrape a sample from the tank wall. The Suction and Strain Sampler is used to gather a remote submerged sample or filter a solid sample from supernate. The Vial Snapper Grab Sampler is

  17. Determination of respirable-sized crystalline silica in different ambient environments in the United Kingdom with a mobile high flow rate sampler utilising porous foams to achieve the required particle size selection

    Science.gov (United States)

    Stacey, Peter; Thorpe, Andrew; Roberts, Paul; Butler, Owen

    2018-06-01

    Inhalation of respirable crystalline silica (RCS) can cause diseases including silicosis and cancer. Levels of RCS close to an emission source are measured but little is known about the wider ambient exposure from industry emissions or natural sources. The aim of this work is to report the RCS concentrations obtained from a variety of ambient environments using a new mobile respirable (PM4) sampler. A mobile battery powered high flow rate (52 L min-1) sampler was developed and evaluated for particulate aerosol sampling employing foams to select the respirable particle size fraction. Sampling was conducted in the United Kingdom at site boundaries surrounding seven urban construction and demolition and five sand quarry sites. These are compared with data from twelve urban aerosol samples and from repeat measurements from a base line study at a single rural site. The 50% particle size penetration (d50) through the foam was 4.3 μm. Over 85% of predict bias values were with ±10% of the respirable convention, which is based on a log normal curve. Results for RCS from all construction and quarry activities are generally low with a 95 th percentile of 11 μg m-3. Eighty percent of results were less than the health benchmark value of 3 μg m-3 used in some states in America for ambient concentrations. The power cutting of brick and the largest demolition activities gave the highest construction levels. Measured urban background RCS levels were typically below 0.3 μg m-3 and the median RCS level, at a rural background location, was 0.02 μg m-3. These reported ambient RCS concentrations may provide useful baseline values to assess the wider impact of fugitive, RCS containing, dust emissions into the wider environment.

  18. Determination of radionuclide concentrations in ground level air using the ASS-500 high volume sampler

    International Nuclear Information System (INIS)

    Frenzel, E.; Arnold, D.; Wershofen, H.

    1996-01-01

    A method for determination of radionuclide concentrations in air aerosol samples collected by the high volume aerosol sampler ASS-500 was elaborated. The aerosol sampling station ASS-500 is a Stand alone, all-weather proofed instrument. It is designed for representative sampling of airborne radionuclides from ground level air at a height of about 1.5 m above ground level. The ASS-500 station enables continuous air monitoring both normal and emergency Situations. The collection of aerosols on the Petrianov FPP-15-1.5 type filter out of an air volume of about 100,000 m 3 (sampling period 1 wk) or of about 250,000 m 3 (sampling period 3 wk) admits accurate spectrometric low level measurements of natural and artificial radionuclides. The achieved detection limit is 0.5 μBq m -3 and 0.2 μBq m -3 for 137 Cs, respectively. A new developed air flow Meter system allows to enhance the collected air volume to about 150,000 m 3 per week and lowers the detection limit to -3 for 137 Cs for weekly collected aerosol samples. In Poland the CLOR uses 9 Stations ASS-500 at different sites as atmospheric radioactivity control system. On the basis of spectrometric measurements of natural and artificial radionuclides in the collected aerosol samples at the different sites, CLOR establishes a weekly report about the radiological situation at Poland for responsible authorities. The very low achievable detection limit of the Station ASS-500 due 10 the high air flow fate and the long possible sampling period were the key argument for other government radiation protection authorities in Europe to introduce the Station ASS-500 into their low level radionuclide atmospheric monitoring programs (Austria, Belarus, France, Germany, Iceland, Spain, Switzerland, Ukraine)

  19. Gas adsorption in Mg-porphyrin-based porous organic frameworks: A computational simulation by first-principles derived force field.

    Science.gov (United States)

    Pang, Yujia; Li, Wenliang; Zhang, Jingping

    2017-09-15

    A novel type of porous organic frameworks, based on Mg-porphyrin, with diamond-like topology, named POF-Mgs is computationally designed, and the gas uptakes of CO 2 , H 2 , N 2 , and H 2 O in POF-Mgs are investigated by Grand canonical Monte Carlo simulations based on first-principles derived force fields (FF). The FF, which describes the interactions between POF-Mgs and gases, are fitted by dispersion corrected double-hybrid density functional theory, B2PLYP-D3. The good agreement between the obtained FF and the first-principle energies data confirms the reliability of the FF. Furthermore our simulation shows the presence of a small amount of H 2 O (≤ 0.01 kPa) does not much affect the adsorption quantity of CO 2 , but the presence of higher partial pressure of H 2 O (≥ 0.1 kPa) results in the CO 2 adsorption decrease significantly. The good performance of POF-Mgs in the simulation inspires us to design novel porous materials experimentally for gas adsorption and purification. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  20. Feasibility Studies for Production of Pellet Grade Concentrate from Sub Grade Iron Ore Using Multi Gravity Separator

    Science.gov (United States)

    Rao, Gottumukkala Venkateswara; Markandeya, R.; Kumar, Rajan

    2018-04-01

    An attempt has been made to utilise Sub Grade Iron Ore by producing pellet grade concentrate from Deposit 5, Bacheli Complex, Bailadila, Chhattisgarh, India. The `as received' Run of Mine (ROM) sample assayed 40.80% Fe, 40.90% SiO2. Mineralogical studies indicated that the main ore mineral is Hematite and lone gangue mineral is Quartz. Mineral liberation studies indicated that, the ore mineral Hematite and gangue mineral Quartz are getting liberated below 100 microns. The stage crushed and ground sample was subjected to concentration by using a Multi Gravity Separator (MGS). Rougher Multi Gravity Separation (MGS) experimental results were optimised to recover highest possible iron values. A concentrate of 55.80% Fe with a yield of 61.73% by weight with a recovery of 84.42% Iron values was obtained in rougher MGS concentrate. Further experiments were carried out with rougher MGS concentrate to produce a concentrate suitable for commercial grade pellet concentrate. It was proved that a concentrate assaying 66.67% Fe, 3.12% SiO2 with an yield of 45.08% by weight and with a recovery of 73.67% iron values in the concentrate.

  1. Shotgun proteomics deciphered age/division of labor-related functional specification of three honeybee (Apis mellifera L.) exocrine glands.

    Science.gov (United States)

    Fujita, Toshiyuki; Kozuka-Hata, Hiroko; Hori, Yutaro; Takeuchi, Jun; Kubo, Takeo; Oyama, Masaaki

    2018-01-01

    The honeybee (Apis mellifera L.) uses various chemical signals produced by the worker exocrine glands to maintain the functioning of its colony. The roles of worker postcerebral glands (PcGs), thoracic glands (TGs), and mandibular glands (MGs) and the functional changes they undergo according to the division of labor from nursing to foraging are not as well studied. To comprehensively characterize the molecular roles of these glands in workers and their changes according to the division of labor of workers, we analyzed the proteomes of PcGs, TGs, and MGs from nurse bees and foragers using shotgun proteomics technology. We identified approximately 2000 proteins from each of the nurse bee or forager glands and highlighted the features of these glands at the molecular level by semiquantitative enrichment analyses of frequently detected, gland-selective, and labor-selective proteins. First, we found the high potential to produce lipids in PcGs and MGs, suggesting their relation to pheromone production. Second, we also found the proton pumps abundant in TGs and propose some transporters possibly related to the saliva production. Finally, our data unveiled candidate enzymes involved in labor-dependent acid production in MGs.

  2. ANALYSIS OF AIR QUALITY IN SELECTED AREAS OF A POULTRY PROCESSING PLANT WITH THE USE OF A MICROBIOLOGICAL AIR SAMPLER

    Directory of Open Access Journals (Sweden)

    P Konieczny

    Full Text Available ABSTRACT The aim of the study was to analyze the air quality in selected production facilities specified as the so-called "high-risk zones". Air samples were analyzed using either the sedimentation or the impaction methods. The impaction method showed the applicability of the air sampler in in-situ measurements. An increase in the numbers of aerobic bacteria was observed in most air sample collection sites as the duration of the production time increased. At the three successive dates, it amounted to 163 cfu/m3, 205 cfu/m3, and 324 cfu/m3, respectively. Such dependence was not observed by the of sedimentation method. It was stated that the impaction technique is better to precisely determine numbers of bacteria, yeast, and molds in the air of poultry processing areas. Analyses showed a high level of microbial air contamination in the examined production areas in relation to the guidelines applied in the assessment of indoor air contamination. Based on the recorded results, it was recommended to undertake immediate corrective actions, consisting in the replacement of filters in the refrigeration and air conditioning equipment, as well as to provide comprehensive training for the employees working in the selected facilities.

  3. Science and Science Fiction

    Science.gov (United States)

    Oravetz, David

    2005-01-01

    This article is for teachers looking for new ways to motivate students, increase science comprehension, and understanding without using the old standard expository science textbook. This author suggests reading a science fiction novel in the science classroom as a way to engage students in learning. Using science fiction literature and language…

  4. Comparison of pore water samplers and cryogenic distillation under laboratory and field conditions for soil water stable isotope analysis.

    Science.gov (United States)

    Thoma, Michael; Frentress, Jay; Tagliavini, Massimo; Scandellari, Francesca

    2018-02-15

    We used pore water samplers (PWS) to sample for isotope analysis (1) only water, (2) soil under laboratory conditions, and (3) soil in the field comparing the results with cryogenic extraction (CE). In (1) and (2), no significant differences between source and water extracted with PWS were detected with a mean absolute difference (MAD) always lower than 2 ‰ for δ 2 H and 1 ‰ for δ 18 O. In (2), CE water was more enriched than PWS-extracted water, with a MAD respect to source water of roughly 8 ‰ for δ 2 H and 4 ‰ for δ 18 O. In (3), PWS water was enriched relative to CE water by 3 ‰ for δ 2 H and 0.9 ‰ for δ 18 O. The latter result may be due to the distinct water portions sampled by the two methods. Large pores, easily sampled by PWS, likely retain recent, and enriched, summer precipitation while small pores, only sampled by CE, possibly retain isotopically depleted water from previous winter precipitation or irrigation inputs. Accuracy and precision were greater for PWS relative to CE. PWS is therefore suggested as viable tool to extract soil water for stable isotope analysis, particularly for soils used in this study (sandy and silty loams).

  5. Concentrations, Trends, and Air-Water Exchange of PAHs and PBDEs Derived from Passive Samplers in Lake Superior in 2011.

    Science.gov (United States)

    Ruge, Zoe; Muir, Derek; Helm, Paul; Lohmann, Rainer

    2015-12-01

    Polycyclic aromatic hydrocarbons (PAHs) and polybrominated diphenylethers (PBDEs) are both currently released into the environment from anthropogenic activity. Both are hence primarily associated with populated or industrial areas, although wildfires can be an important source of PAHs, as well. Polyethylene passive samplers (PEs) were simultaneously deployed in surface water and near surface atmosphere to determine spatial trends and air-water gaseous exchange of 21 PAHs and 11 PBDEs at 19 sites across Lake Superior in 2011. Surface water and atmospheric PAH concentrations were greatest at urban sites (up to 65 ng L(-1) and 140 ng m(-3), respectively, averaged from June to October). Near populated regions, PAHs displayed net air-to-water deposition, but were near equilibrium off-shore. Retene, probably depositing following major wildfires in the region, dominated dissolved PAH concentrations at most Lake Superior sites. Atmospheric and dissolved PBDEs were greatest near urban and populated sites (up to 6.8 pg L(-1) and 15 pg m(-3), respectively, averaged from June to October), dominated by BDE-47. At most coastal sites, there was net gaseous deposition of BDE-47, with less brominated congeners contributing to Sault Ste. Marie and eastern open lake fluxes. Conversely, the central open lake and Eagle Harbor sites generally displayed volatilization of PBDEs into the atmosphere, mainly BDE-47.

  6. Five years of nitrogen dioxide measurement with diffusion tube samplers at over 1000 sites in the UK

    Science.gov (United States)

    Stevenson, Ken; Bush, Tony; Mooney, Diane

    In 1993, a large (>1000 monitoring sites) co-ordinated monitoring network for nitrogen dioxide, using diffusion tube samplers, was established in urban areas throughout the UK. The primary aim of this network is to assess the spatial and temporal distribution of NO 2 throughout the UK and highlight areas of high concentration which may require more detailed monitoring with automatic analysers. This paper presents a summary of the results for the first 5-years of monitoring, 1993-1997 inclusive. The network has shown that highest concentrations occur in London and urban areas of Yorkshire and Humberside and the East and West Midlands of the UK. Averaged over the whole of the UK, NO 2 concentrations have been remarkably similar for most of the 5 years, though a significant decrease was observed at urban background locations in 1997. Overall, average NO 2 concentrations during 1997 were 23 ppb at kerbside locations and 13 ppb at urban background locations. The results of the network have been used by the Department of Environment, Transport and the Regions as one of the criteria for the selection of priority areas for expansion of the UK Automatic Urban Network in recent years. Extensive quality assurance and control procedures incorporated into the network ensure that the estimated accuracy of the data is broadly comparable with the accuracy requirement for indicative monitoring specified in the EU "daughter" Directive for NO2 (±25%) . The complete dataset of results for the network can be found on the world wide web at http://www.environment.detr.gov.uk/airq/aqinfo.htm.

  7. Chemical Properties of Brown Carbon Aerosol Generated at the Missoula Fire Sciences Laboratory

    Science.gov (United States)

    Washenfelder, R. A.; Womack, C.; Franchin, A.; Middlebrook, A. M.; Wagner, N.; Manfred, K.

    2017-12-01

    Aerosol scattering and absorption are still among the largest uncertainties in quantifying radiative forcing. Biomass burning is a major source of light-absorbing carbonaceous aerosol in the United States. These aerosol are generally classified into two categories: black carbon (graphitic-like aerosol that absorbs broadly across the ultraviolet and visible spectral regions) and brown carbon (organic aerosol that absorbs strongly in the ultraviolet and near-visible spectral regions). The composition, volatility, and chemical aging of brown carbon are poorly known, but are important to understanding its radiative effects. We deployed three novel instruments to the Missoula Fire Sciences Laboratory in 2016 to measure brown carbon absorption: a photoacoustic spectrometer, broadband cavity enhanced spectrometer, and particle-into-liquid sampler coupled to a liquid waveguide capillary cell. The instruments sampled from a shared inlet with well-characterized dilution and thermal denuding. We sampled smoke from 32 controlled burns of fuels relevant to western U.S. wildfires. We use these measurements to determine the volatility of water-soluble brown carbon, and compare this to the volatility of water-soluble organic aerosol and total organic aerosol. We further examine the wavelength-dependence of the water-soluble brown carbon absorption as a function of denuder temperature. Together this gives new information about the solubility, volatility, and chemical composition of brown carbon.

  8. Development of a Proof of Concept Low Temperature Superfluid Magnetic Pump with Applications

    Science.gov (United States)

    Jahromi, Amir E.

    State of the art particle and photon detectors such as Transition Edge Sensors (TES) and Microwave Kinetic Inductance Detectors (MKID) use large arrays of sensors or detectors for space science missions. As the size of these space science detectors increases, future astrophysics missions will require sub-Kelvin coolers over larger areas. This leads to not only increased cooling power requirements, but also a requirement for distributed sub-Kelvin cooling. Development of a proof of concept Superfluid Magnetic Pump is discussed in this work. This novel low temperature, no moving part pump can replace the existing bellows-piston driven 4He or 3He- 4He mixture compressor/circulators used in various sub Kelvin refrigeration systems such as dilution, Superfluid pulse tube, or active magnetic regenerative refrigerators. Due to its superior thermal transport properties this pump can also be used as a simple circulator of sub-Lambda 4He to distribute cooling over large surface areas. The pump discussed in this work was experimentally shown to produce a maximum flow rate of 440 mg/s (averaged over cycle), 665 mg/s (peak) and produced a maximum pressure difference of 2323 Pascal. This pump worked in an "ideal" thermodynamic state: The experimental results matched with the theoretical values predicted by a computer model. Pump curves were developed to map the performance of this pump. This successful demonstration will enable this novel pump to be put to test in suitable sub Kelvin refrigeration systems. Numerical modeling of an Active Magnetic Regenerative Refrigerator (AMRR) that uses the Superfluid Magnetic Pump (SMP) to circulate liquid 3He-4He through a magnetic regenerator is presented as a potential application of such a pump.

  9. Supervisory Control for Real Time Reactive Power Flow Optimization in Islanded Microgrids

    DEFF Research Database (Denmark)

    Milczarek, Adam; Vasquez, Juan Carlos; Malinowski, Mariusz

    2013-01-01

    -line measurements. Similarly to any process system, MG hierarchical control is divided into three levels. However, an additional control algorithm is required to manage power transmission between sources and loads, maximizing efficiency and minimizing transmission losses. This real-time optimization problem......A microgrid (MG) is a local energy system consisting of a number of energy sources, energy storage units and loads that operate connected to the main electrical grid or autonomously. MGs include wind, solar or other renewable energy sources. MGs provide flexibility, reduce the main electricity grid...... dependence and contribute to change the large centralized production paradigm to local and distributed generation. However, such energy systems require complex management, advanced control and optimization. Interest on MGs hierarchical control has increased due to the availability of cheap on...

  10. Do Gender-Science Stereotypes Predict Science Identification and Science Career Aspirations among Undergraduate Science Majors?

    Science.gov (United States)

    Cundiff, Jessica L.; Vescio, Theresa K.; Loken, Eric; Lo, Lawrence

    2013-01-01

    The present research examined whether gender-science stereotypes were associated with science identification and, in turn, science career aspirations among women and men undergraduate science majors. More than 1,700 students enrolled in introductory science courses completed measures of gender-science stereotypes (implicit associations and…

  11. Toe of Ganges Chasma Landslide ( 8.0 S, 44.4W)

    Science.gov (United States)

    2001-01-01

    This Mars Global Surveyor (MGS) Mars Orbiter Camera (MOC) image shows shear striations, dark dunes banked up against the toe of the slide and over-riding light-toned ripples and boulders on surface of slide. These features can be used to determine quantitative aspects of surface processes.Malin Space Science Systems and the California Institute of Technology built the MOC using spare hardware from the Mars Observer mission. MSSS operates the camera from its facilities in San Diego, CA. The Jet Propulsion Laboratory's Mars Surveyor Operations Project operates the Mars Global Surveyor spacecraft with its industrial partner, Lockheed Martin Astronautics, from facilities in Pasadena, CA and Denver, CO.

  12. Exomars orbiter science and data-relay mission / looking for trace gases on Mars

    Science.gov (United States)

    Fratacci, Olivier

    spectrometers, mapper and imagers will be embarked, providing an enhanced science return compared to already flying instruments on previous Mars missions like MGS, MEX and MRO. In particular trace gases detection by sun occultation is promoted as first priority followed by quasi continuous limb to limb atmosphere scan and strategic surface high resolution imaging. The multiple instrument pointing requirements combined with a non-Sun-synchronous orbit, led to selection of a "Sun-nadir yaw steering" pointing strategy. A designated axis is pointed to nadir, while the yaw orientation about nadir is controlled to keep the long axis of the solar arrays normal to the Sun vector. This pointing strategy keeps a spacecraft face always pointed away from both the Sun and Mars allowing implementation of the radiators of cryogenic instruments. After the 2 years science phase the OM will also provide a data-relay function with a UHF proximity link for about four years to all future Mars surface assets including the Exomars Rover planned for launch in 2018. Thales Alenia Space will build the CRSM on the basis of the existing Spacebus telecommunication platform to reduce costs and meet the Exomars challenging performance and schedule. The OHB company in Bremen will procure and assemble the Mechanical, Thermal and Propulsion subsystems. The system PDR is planned end of 2010 and the announcement of opportunities for science payloads was issued in January 2010.

  13. An invertebrate stomach's view on vertebrate ecology: certain invertebrates could be used as "vertebrate samplers" and deliver DNA-based information on many aspects of vertebrate ecology.

    Science.gov (United States)

    Calvignac-Spencer, Sébastien; Leendertz, Fabian H; Gilbert, M Thomas P; Schubert, Grit

    2013-11-01

    Recent studies suggest that vertebrate genetic material ingested by invertebrates (iDNA) can be used to investigate vertebrate ecology. Given the ubiquity of invertebrates that feed on vertebrates across the globe, iDNA might qualify as a very powerful tool for 21st century population and conservation biologists. Here, we identify some invertebrate characteristics that will likely influence iDNA retrieval and elaborate on the potential uses of invertebrate-derived information. We hypothesize that beyond inventorying local faunal diversity, iDNA should allow for more profound insights into wildlife population density, size, mortality, and infectious agents. Based on the similarities of iDNA with other low-quality sources of DNA, a general technical framework for iDNA analyses is proposed. As it is likely that no such thing as a single ideal iDNA sampler exists, forthcoming research efforts should aim at cataloguing invertebrate properties relevant to iDNA retrieval so as to guide future usage of the invertebrate tool box. © 2013 WILEY Periodicals, Inc.

  14. Science of science.

    Science.gov (United States)

    Fortunato, Santo; Bergstrom, Carl T; Börner, Katy; Evans, James A; Helbing, Dirk; Milojević, Staša; Petersen, Alexander M; Radicchi, Filippo; Sinatra, Roberta; Uzzi, Brian; Vespignani, Alessandro; Waltman, Ludo; Wang, Dashun; Barabási, Albert-László

    2018-03-02

    Identifying fundamental drivers of science and developing predictive models to capture its evolution are instrumental for the design of policies that can improve the scientific enterprise-for example, through enhanced career paths for scientists, better performance evaluation for organizations hosting research, discovery of novel effective funding vehicles, and even identification of promising regions along the scientific frontier. The science of science uses large-scale data on the production of science to search for universal and domain-specific patterns. Here, we review recent developments in this transdisciplinary field. Copyright © 2018 The Authors, some rights reserved; exclusive licensee American Association for the Advancement of Science. No claim to original U.S. Government Works.

  15. Science and data science.

    Science.gov (United States)

    Blei, David M; Smyth, Padhraic

    2017-08-07

    Data science has attracted a lot of attention, promising to turn vast amounts of data into useful predictions and insights. In this article, we ask why scientists should care about data science. To answer, we discuss data science from three perspectives: statistical, computational, and human. Although each of the three is a critical component of data science, we argue that the effective combination of all three components is the essence of what data science is about.

  16. Surface Properties of Squalene/Meibum Films and NMR Confirmation of Squalene in Tears

    Directory of Open Access Journals (Sweden)

    Slavyana Ivanova

    2015-09-01

    Full Text Available Squalene (SQ possesses a wide range of pharmacological activities (antioxidant, drug carrier, detoxifier, hydrating, emollient that can be of benefit to the ocular surface. It can come in contact with human meibum (hMGS; the most abundant component of the tear film lipid layer as an endogenous tear lipid or from exogenous sources as eyelid sebum or pharmaceuticals. The aims of this study were to determine (i if SQ is in tear lipids and (ii its influence on the surface properties of hMGS films. Heteronuclear single quantum correlation NMR confirmed 7 mol % SQ in Schirmer’s strips extracts. The properties of SQ/hMGS pseudo-binary films at the air/water interface were studied with Langmuir surface balance, stress-relaxation dilatational rheology and Brewster angle microscopy. SQ does not possess surfactant properties. When mixed with hMGS squalene (i localized over the layers’ thinner regions and (ii did not affect the film pressure at high compression. Therefore, tear SQ is unlikely to instigate dry eye, and SQ can be used as a safe and “inert” ingredient in formulations to protect against dry eye. The layering of SQ over the thinner film regions in addition to its pharmacological properties could contribute to the protection of the ocular surface.

  17. The pathogenic persona of community-associated oral streptococci.

    Science.gov (United States)

    Whitmore, Sarah E; Lamont, Richard J

    2011-07-01

    The mitis group streptococci (MGS) are widespread in the oral cavity and are traditionally associated with oral health. However, these organisms have many attributes that contribute to the development of pathogenic oral communities. MGS adhere rapidly to saliva-coated tooth surfaces, thereby providing an attachment substratum for more overtly pathogenic organisms such as Porphyromonas gingivalis, and the two species assemble into heterotypic communities. Close physical association facilitates physiologic support, and pathogens such as Aggregatibacter actinomycetemcomitans display resource partitioning to favour carbon sources generated by streptococcal metabolism. MGS exchange information with community members through a number of interspecies signalling systems including AI-2 and contact dependent mechanisms. Signal transduction systems induced in P. gingivalis are based on protein dephosphorylation mediated by the tyrosine phosphatase Ltp1, and converge on a LuxR-family transcriptional regulator, CdhR. Phenotypic responses in P. gingivalis include regulation of hemin uptake systems and gingipain activity, processes that are intimately linked to the virulence of the organism. Furthermore, communities of S. gordonii with P. gingivalis or with A. actinomycetemcomitans are more pathogenic in animal models than the constituent species alone. We propose that MGS should be considered accessory pathogens, organisms whose pathogenic potential only becomes evident in the context of a heterotypic microbial community. © 2011 Blackwell Publishing Ltd.

  18. Decentralised control method for DC microgrids with improved current sharing accuracy

    DEFF Research Database (Denmark)

    Yang, Jie; Jin, Xinmin; Wu, Xuezhi

    2017-01-01

    A decentralised control method that deals with current sharing issues in dc microgrids (MGs) is proposed in this study. The proposed method is formulated in terms of ‘modified global indicator’ concept, which was originally proposed to improve reactive power sharing in ac MGs. In this work......, the ‘modified global indicator’ concept is extended to coordinate dc MGs, which aims to preserve the main features offered by decentralised control methods such as no need of communication links, central controller or knowledge of the microgrid topology and parameters. This global indicator is inserted between...... a shunt virtual resistance. The operation under multiple dc-buses is also included in order to enhance the applicability of the proposed controller. A detailed mathematical model including the effect of network mismatches is derived for analysis of the stability of the proposed controller. The feasibility...

  19. Primary Science Interview: Science Sparks

    Science.gov (United States)

    Bianchi, Lynne

    2016-01-01

    In this "Primary Science" interview, Lynne Bianchi talks with Emma Vanstone about "Science Sparks," which is a website full of creative, fun, and exciting science activity ideas for children of primary-school age. "Science Sparks" started with the aim of inspiring more parents to do science at home with their…

  20. An improved, automated whole air sampler and gas chromatography mass spectrometry analysis system for volatile organic compounds in the atmosphere

    Science.gov (United States)

    Lerner, Brian M.; Gilman, Jessica B.; Aikin, Kenneth C.; Atlas, Elliot L.; Goldan, Paul D.; Graus, Martin; Hendershot, Roger; Isaacman-VanWertz, Gabriel A.; Koss, Abigail; Kuster, William C.; Lueb, Richard A.; McLaughlin, Richard J.; Peischl, Jeff; Sueper, Donna; Ryerson, Thomas B.; Tokarek, Travis W.; Warneke, Carsten; Yuan, Bin; de Gouw, Joost A.

    2017-01-01

    Volatile organic compounds were quantified during two aircraft-based field campaigns using highly automated, whole air samplers with expedited post-flight analysis via a new custom-built, field-deployable gas chromatography-mass spectrometry instrument. During flight, air samples were pressurized with a stainless steel bellows compressor into electropolished stainless steel canisters. The air samples were analyzed using a novel gas chromatograph system designed specifically for field use which eliminates the need for liquid nitrogen. Instead, a Stirling cooler is used for cryogenic sample pre-concentration at temperatures as low as -165 °C. The analysis system was fully automated on a 20 min cycle to allow for unattended processing of an entire flight of 72 sample canisters within 30 h, thereby reducing typical sample residence times in the canisters to less than 3 days. The new analytical system is capable of quantifying a wide suite of C2 to C10 organic compounds at part-per-trillion sensitivity. This paper describes the sampling and analysis systems, along with the data analysis procedures which include a new peak-fitting software package for rapid chromatographic data reduction. Instrument sensitivities, uncertainties and system artifacts are presented for 35 trace gas species in canister samples. Comparisons of reported mixing ratios from each field campaign with measurements from other instruments are also presented.