WorldWideScience

Sample records for mg dr capsule

  1. Posterior capsule opacification and neovascularization treated with intravitreal bevacizumab and Nd:YAG capsulotomy

    Directory of Open Access Journals (Sweden)

    Grimelda Yuriana Sánchez-Castro

    2008-10-01

    Full Text Available Grimelda Yuriana Sánchez-Castro1, Alejandra Hitos-Fájer1, Erick Mendoza-Schuster1, Raul Velez-Montoya2, Cecilio Francisco Velasco-Barona11Asociación para Evitar la Ceguera en México. Hospital “Dr. Luis Sánchez Bulnes”, México, D.F. Ophthalmology Department – Anterior Segment; 2Asociación para Evitar la Ceguera en México. Hospital “Dr. Luis Sánchez Bulnes”, México, D.F. Ophthalmology Department – Retina departmentAbstract: We reported a 75-year-old diabetic man, who developed opacification and neovascularization of the posterior capsule after extracapsular cataract extraction and posterior chamber intraocular lens implantation. The patient was treated with two injections of 2.5 mg of intravitreal bevacizumab. The treatment produced an important regression of the posterior capsular new vessels, allowing us to perform a successful Nd:YAG capsulotomy, clearing the visual axis and improving the visualization of the posterior pole. Even though, best corrected visual acuity was 20/200 due to diabetic macular edema.Keywords: posterior capsule opacification, posterior capsule neovascularization, cataract surgery, postoperative complications, intravitreal bevacizumab

  2. High-speed precision weighing of pharmaceutical capsules

    International Nuclear Information System (INIS)

    Bürmen, Miran; Pernuš, Franjo; Likar, Boštjan

    2009-01-01

    In this paper, we present a cost-effective method for fast and accurate in-line weighing of hard gelatin capsules based on the optimized capacitance sensor and real-time processing of the capsule capacitance profile resulting from 5000 capacitance measurements per second. First, the effect of the shape and size of the capacitive sensor on the sensitivity and stability of the measurements was investigated in order to optimize the performance of the system. The method was tested on two types of hard gelatin capsules weighing from 50 mg to 650 mg. The results showed that the capacitance profile was exceptionally well correlated with the capsule weight with the correlation coefficient exceeding 0.999. The mean precision of the measurements was in the range from 1 mg to 3 mg, depending on the size of the capsule and was significantly lower than the 5% weight tolerances usually used by the pharmaceutical industry. Therefore, the method was found feasible for weighing pharmaceutical hard gelatin capsules as long as certain conditions are met regarding the capsule fill properties and environment stability. The proposed measurement system can be calibrated by using only two or three sets of capsules with known weight. However, for most applications it is sufficient to use only empty and nominally filled capsules for calibration. Finally, a practical application of the proposed method showed that a single system is capable of weighing around 75 000 capsules per hour, while using multiple systems could easily increase the inspection rate to meet almost any requirements

  3. Separation of DR synthesized Ti-Mg Alloy by dissolution of waste by-products in acid media

    CSIR Research Space (South Africa)

    Mushove, T

    2010-06-01

    Full Text Available Of DR Synthesized Ti-Mg Alloy By Dissolution Of Waste By-Products In Acid Media. The dissolution experiments were done in a Julabo SW23 waterbath shaker, with 300 ml flasks. Acid solution of predetermined molarity was charged into a flask and heated... of the diffraction peaks of Mg and TiO2. The reduction of TiO2 at 32hrs of milling was evaluated from Equation 6.2 to be 90.4% (4). Calculated proportions of products, and the respective masses from a 2g sample, are shown in Table 1. Constituent TiO2 Ti-Mg Mg...

  4. Reinforcing effects of caffeine in coffee and capsules.

    Science.gov (United States)

    Griffiths, R R; Bigelow, G E; Liebson, I A

    1989-09-01

    In a residential research ward the reinforcing and subjective effects of caffeine were studied under double-blind conditions in volunteer subjects with histories of heavy coffee drinking. In Experiment 1, 6 subjects had 13 opportunities each day to self-administer either a caffeine (100 mg) or a placebo capsule for periods of 14 to 61 days. All subjects developed a clear preference for caffeine, with intake of caffeine becoming relatively stable after preference had been attained. Preference for caffeine was demonstrated whether or not preference testing was preceded by a period of 10 to 37 days of caffeine abstinence, suggesting that a recent history of heavy caffeine intake (tolerance/dependence) was not a necessary condition for caffeine to function as a reinforcer. In Experiment 2, 6 subjects had 10 opportunities each day to self-administer a cup of coffee or (on different days) a capsule, dependent upon completing a work requirement that progressively increased and then decreased over days. Each day, one of four conditions was studied: caffeinated coffee (100 mg/cup), decaffeinated coffee, caffeine capsules (100 mg/capsule), or placebo capsules. Caffeinated coffee maintained the most self-administration, significantly higher than decaffeinated coffee and placebo capsules but not different from caffeine capsules. Both decaffeinated coffee and caffeine capsules were significantly higher than placebo capsules but not different from each other. In both experiments, subject ratings of "linking" of coffee or capsules covaried with the self-administration measures. These experiments provide the clearest demonstrations to date of the reinforcing effects of caffeine in capsules and in coffee.

  5. First clinical exploration of Buddleja officinalis and Xueshuangtong capsule on mild and moderate simple diabetic retinopathy

    Directory of Open Access Journals (Sweden)

    Hong Hu

    2013-11-01

    Full Text Available AIM: To observe the clinical effect of Buddleja officinalis and Xueshuangtong capsule treating the mild and moderate simple diabetic retinopathy(sDR. METHODS: Based on the strict control of blood glucose and blood pressure, eighty patients(160 eyeswith mild and moderate sDR were randomized into two groups equally: Buddleja officinalis(15g,tidand Xueshuangtong capsule administered to group A and only Xueshuangtong capsule administered to group B. They are taken before meals half an hour. The vision, funduscopy, FFA, fundus photography and traditional chinese medcine symptoms(TCMSwere evalutated before and after treatment in 7d,42 d respectively.RESULTS: There were no significant difference between two groups in terms of patients' gender, age, DM course, visual acuity, course of disease and TCM syndrome.(χ 2 sex=0.472, P>0.05; tage=1.742,tDM condition=0.716,tvision=0.662,tDR degree=1.276,tDR condition=0.562,t TCMS=0.616,P >0.05; Follow up for 42d on average after treatment the effective rate of fundus lesions of group A was 56%and the total effective rate was 82%,while the effective rate of group B was 32% and the total effective rate was 66%. The result showed that the curative effect of group A was better than that of group B. There were statistically significant difference for the effective rate between the two groups(χ2=8.025, Pχ 2=5.980,PCONCLUSION: Buddleja officinalis and Xueshuangtong capsule can improve the vision of patients with the mild and moderate sDR patients, the fundus lesions and the TCMS.

  6. Hydrocolloid liquid-core capsules for the removal of heavy-metal cations from water

    Energy Technology Data Exchange (ETDEWEB)

    Nussinovitch, A., E-mail: amos.nussi@mail.huji.ac.il; Dagan, O.

    2015-12-15

    Highlights: • Novel liquid-core capsules with a non-crosslinked alginate core were produced. • Capsules demonstrated highest efficiency adsorption of ∼300 mg Pb{sup 2+}/g alginate. • Regeneration was carried out by suspending capsules in 1 M HNO{sub 3} for 24 h. • Adsorption capacities of the capsules followed the order: Pb{sup 2+} > Cu{sup 2+} > Cd{sup 2+} > Ni{sup 2+}. - Abstract: Liquid-core capsules with a non-crosslinked alginate fluidic core surrounded by a gellan membrane were produced in a single step to investigate their ability to adsorb heavy metal cations. The liquid-core gellan–alginate capsules, produced by dropping alginate solution with magnesium cations into gellan solution, were extremely efficient at adsorbing lead cations (267 mg Pb{sup 2+}/g dry alginate) at 25 °C and pH 5.5. However, these capsules were very weak and brittle, and an external strengthening capsule was added by using magnesium cations. The membrane was then thinned with the surfactant lecithin, producing capsules with better adsorption attributes (316 mg Pb{sup +2}/g dry alginate vs. 267 mg Pb{sup +2}/g dry alginate without lecithin), most likely due to the thinner membrane and enhanced mass transfer. The capsules’ ability to adsorb other heavy-metal cations – copper (Cu{sup 2+}), cadmium (Cd{sup 2+}) and nickel (Ni{sup 2+}) – was tested. Adsorption efficiencies were 219, 197 and 65 mg/g, respectively, and were correlated with the cation’s affinity to alginate. Capsules with the sorbed heavy metals were regenerated by placing in a 1 M nitric acid suspension for 24 h. Capsules could undergo three regeneration cycles before becoming damaged.

  7. Modulation of TRAIL resistance in colon carcinoma cells: Different contributions of DR4 and DR5

    International Nuclear Information System (INIS)

    Geelen, Caroline MM van; Pennarun, Bodvael; Le, Phuong TK; Vries, Elisabeth GE de; Jong, Steven de

    2011-01-01

    rhTRAIL is a therapeutic agent, derived from the TRAIL cytokine, which induces apoptosis in cancer cells by activating the membrane death receptors 4 and 5 (DR4 and DR5). Here, we investigated each receptor's contribution to rhTRAIL sensitivity and rhTRAIL resistance. We assessed whether agonistic DR4 or DR5 antibodies could be used to circumvent rhTRAIL resistance, alone or in combination with various chemotherapies. Our study was performed in an isogenic model comprised of the SW948 human colon carcinoma cell line and its rhTRAIL resistant sub-line SW948-TR. Effects of rhTRAIL and agonistic DR4/DR5 antibodies on cell viability were measured using MTT assays and identification of morphological changes characteristic of apoptosis, after acridine orange staining. Sensitivity to the different death receptor ligands was stimulated using pretreatment with the cytokine IFN-gamma and the proteasome inhibitor MG-132. To investigate the mechanisms underlying the changes in rhTRAIL sensitivity, alterations in expression levels of targets of interest were measured by Western blot analysis. Co-immunoprecipitation was used to determine the composition of the death-inducing signalling complex at the cell membrane. SW948 cells were sensitive to all three of the DR-targeting agents tested, although the agonistic DR5 antibody induced only weak caspase 8 cleavage and limited apoptosis. Surprisingly, agonistic DR4 and DR5 antibodies induced equivalent DISC formation and caspase 8 cleavage at the level of their individual receptors, suggesting impairment of further caspase 8 processing upon DR5 stimulation. SW948-TR cells were cross-resistant to all DR-targeting agents as a result of decreased caspase 8 expression levels. Caspase 8 protein expression was restored by MG-132 and IFN-gamma pretreatment, which also re-established sensitivity to rhTRAIL and agonistic DR4 antibody in SW948-TR. Surprisingly, MG-132 but not IFN-gamma could also increase DR5-mediated apoptosis in SW948

  8. Modulation of TRAIL resistance in colon carcinoma cells: Different contributions of DR4 and DR5

    Directory of Open Access Journals (Sweden)

    de Vries Elisabeth GE

    2011-01-01

    Full Text Available Abstract Background rhTRAIL is a therapeutic agent, derived from the TRAIL cytokine, which induces apoptosis in cancer cells by activating the membrane death receptors 4 and 5 (DR4 and DR5. Here, we investigated each receptor's contribution to rhTRAIL sensitivity and rhTRAIL resistance. We assessed whether agonistic DR4 or DR5 antibodies could be used to circumvent rhTRAIL resistance, alone or in combination with various chemotherapies. Methods Our study was performed in an isogenic model comprised of the SW948 human colon carcinoma cell line and its rhTRAIL resistant sub-line SW948-TR. Effects of rhTRAIL and agonistic DR4/DR5 antibodies on cell viability were measured using MTT assays and identification of morphological changes characteristic of apoptosis, after acridine orange staining. Sensitivity to the different death receptor ligands was stimulated using pretreatment with the cytokine IFN-gamma and the proteasome inhibitor MG-132. To investigate the mechanisms underlying the changes in rhTRAIL sensitivity, alterations in expression levels of targets of interest were measured by Western blot analysis. Co-immunoprecipitation was used to determine the composition of the death-inducing signalling complex at the cell membrane. Results SW948 cells were sensitive to all three of the DR-targeting agents tested, although the agonistic DR5 antibody induced only weak caspase 8 cleavage and limited apoptosis. Surprisingly, agonistic DR4 and DR5 antibodies induced equivalent DISC formation and caspase 8 cleavage at the level of their individual receptors, suggesting impairment of further caspase 8 processing upon DR5 stimulation. SW948-TR cells were cross-resistant to all DR-targeting agents as a result of decreased caspase 8 expression levels. Caspase 8 protein expression was restored by MG-132 and IFN-gamma pretreatment, which also re-established sensitivity to rhTRAIL and agonistic DR4 antibody in SW948-TR. Surprisingly, MG-132 but not IFN

  9. Residual mercury content and leaching of mercury and silver from used amalgam capsules.

    Science.gov (United States)

    Stone, M E; Pederson, E D; Cohen, M E; Ragain, J C; Karaway, R S; Auxer, R A; Saluta, A R

    2002-06-01

    The objective of this investigation was to carry out residual mercury (Hg) determinations and toxicity characteristic leaching procedure (TCLP) analysis of used amalgam capsules. For residual Hg analysis, 25 capsules (20 capsules for one brand) from each of 10 different brands of amalgam were analyzed. Total residual Hg levels per capsule were determined using United States Environmental Protection Agency (USEPA) Method 7471. For TCLP analysis, 25 amalgam capsules for each of 10 brands were extracted using a modification of USEPA Method 1311. Hg analysis of the TCLP extracts was done with USEPA Method 7470A. Analysis of silver (Ag) concentrations in the TCLP extract was done with USEPA Method 6010B. Analysis of the residual Hg data resulted in the segregation of brands into three groups: Dispersalloy capsules, Group A, retained the most Hg (1.225 mg/capsule). These capsules were the only ones to include a pestle. Group B capsules, Valliant PhD, Optaloy II, Megalloy and Valliant Snap Set, retained the next highest amount of Hg (0.534-0.770 mg/capsule), and were characterized by a groove in the inside of the capsule. Group C, Tytin regular set double-spill, Tytin FC, Contour, Sybraloy regular set, and Tytin regular set single-spill retained the least amount of Hg (0.125-0.266 mg/capsule). TCLP analysis of the triturated capsules showed Sybraloy and Contour leached Hg at greater than the 0.2 mg/l Resource Conservation and Recovery Act (RCRA) limit. This study demonstrated that residual mercury may be related to capsule design features and that TCLP extracts from these capsules could, in some brands, exceed RCRA Hg limits, making their disposal problematic. At current RCRA limits, the leaching of Ag is not a problem.

  10. Magnesium Ion Acts as a Signal for Capsule Induction in Cryptococcus neoformans.

    Science.gov (United States)

    Rathore, Sudarshan S; Raman, Thiagarajan; Ramakrishnan, Jayapradha

    2016-01-01

    Cryptococcal meningitis caused by Cryptococcus neoformans, is a common opportunistic neural infection in immunocompromised individuals. Cryptococcus meningitis is associated with fungal burden with larger capsule size in cerebrospinal fluid (CSF). To understand the role of CSF constituents in capsule enlargement, we have evaluated the effect of artificial CSF on capsule induction in comparison with various other capsule inducing media. Two different strains of C. neoformans, an environmental and a clinical isolates were used in the present study. While comparing the various capsule inducing media for the two different strains of C. neoformans, it was observed that the capsule growth was significantly increased when grown in artificial CSF at pH 5.5, temperature 34°C for ATCC C. neoformans and 37°C for Clinical C. neoformans and with an incubation period of 72 h. In addition, artificial CSF supports biofilm formation in C. neoformans. While investigating the individual components of artificial CSF, we found that Mg(2+) ions influence the capsule growth in both environmental and clinical strains of C. neoformans. To confirm our results we studied the expression of four major CAP genes namely, CAP10, CAP59, CAP60, and CAP64 in various capsule inducing media and in different concentrations of Mg(2+) and Ca(2+). Our results on gene expression suggest that, Mg(2+) does have an effect on CAP gene expression, which are important for capsule biosynthesis and virulence. Our findings on the role of Mg(2+) ion as a signal for capsule induction will promote a way to elucidate the control mechanisms for capsule biosynthesis in C. neoformans.

  11. Iodometric determination of ampicillin in proprietary capsules | Ejele ...

    African Journals Online (AJOL)

    The concentration of ampicillin in ampicillin capsule preparations purchased in Owerri main market, Imo State of Nigeria, was determined using the iodometric titration method. The results showed that the ampicillin concentrations in the capsules contained between 250 and 260 mg/cap of ampicillin trihydrate. Statistical ...

  12. A Pharmacokinetic Bioequivalence Study Comparing Pirfenidone Tablet and Capsule Dosage Forms in Healthy Adult Volunteers.

    Science.gov (United States)

    Pan, Lin; Belloni, Paula; Ding, Han Ting; Wang, Jianshuang; Rubino, Christopher M; Putnam, Wendy S

    2017-09-01

    Pirfenidone film-coated tablets were developed to offer an alternative to the marketed capsule formulation. This study assessed the bioequivalence of the tablet and capsule formulations under fed and fasted states. A Phase I, open-label, randomized, four-treatment-period, four-sequence, crossover pharmacokinetics study (NCT02525484) was conducted. Each subject received an 801-mg single dose of pirfenidone as three 267-mg capsules or one 801-mg tablet under fasted and fed conditions. Pirfenidone plasma C max , AUC 0-t and AUC 0-∞ were used to assess bioequivalence. Forty-four subjects were randomized to treatment. The 801-mg tablet in the fasted state met bioequivalence criteria [90% confidence intervals (CI) 80.00-125.00%] for the GLSM ratios of natural log-transformed C max , AUC 0-t and AUC 0-∞ . Under fed conditions, the 801-mg tablet met the bioequivalence criteria for AUC 0-t and AUC 0-∞ , but slightly exceeded the bioequivalence criteria for the C max (90% CI of 108.26-125.60%). The tablet C max was approximately 17% higher than that of the capsules. In the fed state, the tablet C max , and both AUC 0-t and AUC 0-∞ were reduced by 39% and 17%, respectively, relative to the fasted state. The tablet and capsules had acceptable tolerability profiles. The pirfenidone 801-mg tablet met bioequivalence criteria when compared with three 267-mg capsules in the fasted state. The tablet C max was slightly higher relative to capsules in the fed state, but this is not expected to have a clinically meaningful impact on the benefit-risk profile of pirfenidone. This work was supported by F. Hoffmann-La Roche Ltd.

  13. Chaddah, Dr Praveen

    Indian Academy of Sciences (India)

    Home; Fellowship. Fellow Profile. Elected: 1993 Section: Physics. Chaddah, Dr Praveen Ph.D. (Mumbai), FNA, FNASc. Date of birth: 20 December 1951. Specialization: Superconductivity, Low Temperature Physics and Phase Transitions Address: Flat 702, Block 24, Heritage City, MG Road (near Metro Station), Gurgaon ...

  14. Analysis of lomustine drug content in FDA-approved and compounded lomustine capsules.

    Science.gov (United States)

    KuKanich, Butch; Warner, Matt; Hahn, Kevin

    2017-02-01

    OBJECTIVE To determine the lomustine content (potency) in compounded and FDA-approved lomustine capsules. DESIGN Evaluation study. SAMPLE 2 formulations of lomustine capsules (low dose [7 to 11 mg] and high dose [40 to 48 mg]; 5 capsules/dose/source) from 3 compounders and from 1 manufacturer of FDA-approved capsules. PROCEDURES Lomustine content was measured by use of a validated high-pressure liquid chromatography method. An a priori acceptable range of 90% to 110% of the stated lomustine content was selected on the basis of US Pharmacopeia guidelines. RESULTS The measured amount of lomustine in all compounded capsules was less than the stated content (range, 59% to 95%) and was frequently outside the acceptable range (failure rate, 2/5 to 5/5). Coefficients of variation for lomustine content ranged from 4.1% to 16.7% for compounded low-dose capsules and from 1.1% to 10.8% for compounded high-dose capsules. The measured amount of lomustine in all FDA-approved capsules was slightly above the stated content (range, 104% to 110%) and consistently within the acceptable range. Coefficients of variation for lomustine content were 0.5% for low-dose and 2.3% for high-dose FDA-approved capsules. CONCLUSIONS AND CLINICAL RELEVANCE Compounded lomustine frequently did not contain the stated content of active drug and had a wider range of lomustine content variability than did the FDA-approved product. The sample size was small, and larger studies are needed to confirm these findings; however, we recommend that compounded veterinary formulations of lomustine not be used when appropriate doses can be achieved with FDA-approved capsules or combinations of FDA-approved capsules.

  15. The intake of long chain omega 3 fatty acids through fish versus capsules results in greater increments of their plasma levels

    Directory of Open Access Journals (Sweden)

    Visioli Francesco

    2004-03-01

    Full Text Available Omega 3 fatty acids from fish appear to be more cardioprotective than equivalent amounts provided as capsules. We gave volunteers, for six weeks, either 100 g\\\\day of salmon, providing 383 mg of EPA and 544 mg of DHA or one or three capsules of fish oil\\\\day, providing 150 mg of EPA and 106 mg of DHA or 450 mg of EPA and 318 mg of DHA. We also re-evaluated data from a previous study carried out with the same design. Marked increments in plasma EPA and DHA concentrations (μg\\\\mg total lipid and percentages of total fatty acids were recorded at the end of either treatment. Such increments were linearly and significantly correlated with the dose after capsule administration. Notably, increments in plasma EPA and DHA concentration after salmon intake were significantly higher than after administration of capsules. In fact, the same increments would be obtained with at least two- and nine-fold higher doses of EPA and DHA, respectively, if administered with capsules rather than salmon. In turn, we provide experimental evidence that omega 3 fatty acids from fish are more effectively incorporated into plasma lipids than when administered as capsules and that increments in plasma concentrations of EPA and DHA given as capsules are linearly correlated with their intakes.

  16. Pharmacokinetics of Caffeine in the Lens Capsule/Epithelium After Peroral Intake: A Pilot Randomized Controlled Study.

    Science.gov (United States)

    Kronschläger, Martin; Stimpfl, Thomas; Ruiß, Manuel; Hirnschall, Nino; Leisser, Christoph; Findl, Oliver

    2018-04-01

    To determine the pharmacokinetics of perorally administered caffeine, a widely consumed and potent dietary antioxidant, in the anterior lens capsule and lens epithelial cells, a crucial cell monolayer for cataract development. Bilateral cataract patients were scheduled for cataract surgery with a caffeine abstinence of 1 week before surgery of each eye. At the day of surgery of the second eye patients were administered no drink (0-mg group) or coffee with 60-, 120-, or 180-mg caffeine. After capsulorhexis the lens capsule including lens epithelial cells was transferred to a test tube for analysis of caffeine concentration by gas chromatography-mass spectrometry (GC-MS/MS). Coffee consumption significantly (P < 0.05) increased caffeine levels of the lens capsule/epithelium in the 60-, 120-, and 180-mg group. Caffeine concentrations (caffeine ng/lens capsule/epithelium) measured as difference between 1st and 2nd eye were -0.52 ± 1.16 (0-mg group, n = 7), 1.88 ± 2.02 (60-mg group, n = 8), 2.09 ± 0.67 (120-mg group, n = 9), and 3.68 ± 1.86 (180-mg group, n = 9). The increase constant of caffeine in a linear regression model was estimated as a 95% CI 0.02 ± 0.0046 (degrees of freedom; 25; r = 0.85). Peroral intake of coffee significantly increased caffeine concentrations in the lens capsule and lens epithelial cells in a dose-dependent manner. This information is important for further investigations on preventing cataract.

  17. 76 FR 59141 - Determination That LOXITANE (Loxapine Succinate) Capsules and Three Other Drug Products Were Not...

    Science.gov (United States)

    2011-09-23

    ... Applicant NDA 017525 LOXITANE (loxapine Watson Laboratories succinate) Inc., 417 Wakara Capsules, Way, Suite.../milliliter. NDA 020828 FORTOVASE Hoffmann La Roche (saquinavir) Inc., 340 Kingsland Capsule, 200 mg. St...

  18. Membrane support of accelerated fuel capsules for inertial fusion energy reactors

    International Nuclear Information System (INIS)

    Petzoldt, R.W.; Moir, R.W.

    1993-01-01

    The use of a thin membrane to suspend an (inertial fusion energy) fuel capsule in a holder for injection into a reactor chamber is investigated. Capsule displacement and membrane deformation angle are calculated for an axisymmetric geometry for a range of membrane strain and capsule size. This information is used to calculate maximum target accelerations. Membranes must be thin (perhaps of order one micron) to minimize their effect on capsule implosion symmetry. For example, a 5 μm thick cryogenic mylar membrane is calculated to allow 1,000 m/s 2 acceleration of a 3 mm radius, 100 mg capsule. Vibration analysis (for a single membrane support) shows that if membrane vibration is not deliberately minimized, allowed acceleration may be reduced by a factor of four. A two membrane alternative geometry would allow several times greater acceleration. Therefore, alternative membrane geometry's should be used to provide greater target acceleration potential and reduce capsule displacement within the holder (for a given membrane thickness)

  19. Potassium iodide capsule treatment of feline sporotrichosis.

    Science.gov (United States)

    Reis, Erica G; Gremião, Isabella D F; Kitada, Amanda A B; Rocha, Raphael F D B; Castro, Verônica S P; Barros, Mônica B L; Menezes, Rodrigo C; Pereira, Sandro A; Schubach, Tânia M P

    2012-06-01

    Sporotrichosis is a mycosis caused by Sporothrix schenckii. The most affected animal is the cat; it has played an important role in the zoonotic transmission of this disease, especially in Rio de Janeiro, Brazil, since 1998. In order to evaluate the treatment of feline sporotrichosis with potassium iodide, an observational cohort was conducted in 48 cats with sporotrichosis at Instituto de Pesquisa Clínica Evandro Chagas, Fiocruz. All cats received potassium iodide capsules, 2.5 mg/kg to 20 mg/kg q24h. The cure rate was 47.9%, treatment failure was 37.5%, treatment abandonment was 10.4% and death was 4.2%. Clinical adverse effects were observed in 52.1% of the cases. Thirteen cats had a mild increase in hepatic transaminase levels during the treatment, six of them presented clinical signs suggestive of hepatotoxicity. Compared to previous studies with itraconazole and iodide in saturated solution, potassium iodide capsules are an alternative for feline sporotrichosis treatment.

  20. Extraction, quantification, formulation and evaluation of oral capsules from burdock fruits

    Directory of Open Access Journals (Sweden)

    F. Arab

    2017-11-01

    Full Text Available Background and objectives: Burdock (Arcticum lappa L. is a Eurasian species of plants in the sunflower family and has been used for hundreds of years by scientists and traditionally in North America, Europe, Asia and especially in China. It has also been used in gouts, hepatitis, blood pressure and other inflammatory disorders. There are several major compounds in different parts of this species and the main ingredients of the fruits, are arctiin and arctigenin. Methods: In this investigation, we obtained the dried seeds of burdock from Jahad Keshavazi Institute of medicinal plants, Karaj, Iran and ground the fruits and extracted them with ethanol 70% via maceration. Extracted material was filtered and analyzed by HPLC. Results: Quantification of Arctiin via HPLC analysis showed that it was 396.32 mg/g in the total extract. Conclusion: Depending on the measured arctiin, various oral capsule formulations were evaluated using the fruit extract and common fillers, such as Avistel 102, starch and lactose. The standardization of capsules was based on the presence of 396.32 mg/g of arctiin in each 250 mg capsule.

  1. Structure and selectivity trends in crystalline urea-functionalized anion-binding capsules

    Energy Technology Data Exchange (ETDEWEB)

    Rajbanshi, Arbin [Oak Ridge National Laboratory (ORNL); Custelcean, Radu [ORNL

    2012-01-01

    A tripodal trisurea receptor (L1) persistently self-assembles with various divalent oxoanion salts M{sub n}X (M = Na, K, Mg, Ca, Cd; X = SO{sub 4}{sup 2-}, SO{sub 3}{sup 2-}, SeO{sub 4}{sup 2-}, CrO{sub 4}{sup 2-}) into isomorphous series of crystalline frameworks in three different compositions: MX(L1){sub 2}(H{sub 2}O){sub 6} (M = Mg, Ca, Cd) (1), Na{sub 2}X(L1){sub 2}(H{sub 2}O){sub 4} (2) and K{sub 2}X(L1){sub 2}(H{sub 2}O){sub 2} (3). Single-crystal X-ray structural analysis revealed that all three series of structures adopt a NaCl-type topology, consisting of alternating anionic X(L1){sub 2}{sup 2-} capsules and M(H{sub 2}O){sub 6}{sup 2+}, Na{sub 2}(H{sub 2}O){sub 4}{sup 2+} or K{sub 2}(H{sub 2}O){sub 2}{sup 2+} hydrated cations. The capsules provide a complementary environment to tetrahedral oxoanions via 12 hydrogen bonds from six urea groups lining the cavities of the capsules. The persistent formation of the capsules facilitated the investigation of structural trends and structure-selectivity relationships across series 1-3. First, it was found that the size of the capsules is relatively unresponsive to the change in the encapsulated anion, resulting in good shape and size recognition in the separation of anions by competitive crystallizations. Second, it was found that the size of the capsules varies linearly with the size of the external cation, which provides a way for tuning the anion encapsulation selectivity. However, no straightforward dependence was found between the size of the capsules and the relative selectivity for different-sized tetrahedral oxoanions in competitive crystallizations.

  2. A Phase 1 Pharmacokinetic Study of Cysteamine Bitartrate Delayed-Release Capsules Following Oral Administration with Orange Juice, Water, or Omeprazole in Cystinosis.

    Science.gov (United States)

    Armas, Danielle; Holt, Robert J; Confer, Nils F; Checani, Gregg C; Obaidi, Mohammad; Xie, Yuli; Brannagan, Meg

    2018-02-01

    Cystinosis is a rare, metabolic, autosomal recessive, genetic lysosomal storage disorder characterized by an accumulation of cystine in various organs and tissues. Cysteamine bitartrate (CB) is a cystine-depleting aminothiol agent approved in the United States and Europe in immediate-release and delayed-release (DR) formulations for the treatment of nephropathic cystinosis in children and adults. It is recommended that CBDR be administered with fruit juice (except grapefruit juice) for maximum absorption. Omeprazole is a proton pump inhibitor that inhibits gastric acid secretion and, theoretically, may cause the premature release of cysteamine by increasing intragastric pH, thereby affecting the PK of CBDR. This open-label, three-period, randomized study in healthy adult subjects was designed primarily to compare the pharmacokinetics of CBDR capsules after a single oral dose administered with orange juice, water, or multiple oral doses of omeprazole with water at steady state. A total of 32 subjects were randomly assigned to receive study agents in one of two treatment sequences. All subjects completed the study and baseline characteristics of the overall population and the two treatment sequence populations were similar. Peak mean plasma cysteamine concentrations following co-administration of CBDR capsules with orange juice (1892 ng/mL) were higher compared with co-administration with water (1663 ng/mL) or omeprazole 20 mg and water (1712 ng/mL). Mean time to peak plasma concentration was shorter with omeprazole co-administration (2.5 h) compared with orange juice (3.5 h) or water (3.0 h). Statistical comparisons between treatment groups indicated that exposure as assessed by AUC 0-t , AUC 0-∞ , and C max were all within the 80-125% bioequivalence ranges for all comparisons. All treatments were generally well tolerated. Overall, the pharmacokinetics of cysteamine bitartrate DR capsules are not significantly impacted by co-administration with orange juice

  3. In vitro evaluation of extemporaneously compounded slow-release capsules containing morphine sulfate or oxycodone hydrochloride.

    Science.gov (United States)

    Glowiak, Dana L; Green, Julie L; Bowman, Bill J

    2005-01-01

    The in vitro performance of extemporaneously compounded morphine sulfate and oxycodone hydrochloride slow-release capsules was evaluated. Capsules containing varying amoutns of morphine sulfate (15, 60, 200 mg) or oxycodone hydrochloride (10, 80, 200 mg) were prepared and provided by a Phoenix, Arizona, pharmacy. The capsules also contained 40% Methocel E4M Premium to slow the release of their active ingredient and sufficient lactose to fill the capsules. Three batches of each capsule strength were prepared, and replicates from each batch were evlauated using United Stated Pharmacopeia dissolution apparatus II. Samples were taken at regular time intervals over 24 hours. After 1 hour the pH of the dissolution medium was adjusted form 1.2 to 4.0, and after 2 hours the pH was adjusted to 6.8. The amount of drug released at each time point was determined spectrophotometrically. The compounded capsules released 14% to 23%, 67% to 85% and 93% to 98% of their active ingredient after 0.5, 4 and 12 hours, respectively. The relative standard deviations between the replicates from each batch were less than 10% for most time points. The percent of drug released over the first 4 hours was linear (r squared = 0.9409-0.9999) when plotted versus time 1/2, indicating adherence to the simplified Higuchi model. Statistical analysis of the Higuchi dissolution constants indicated a significant difference (P less than 0.05) between batch No.3 and the other two batches of 200-mg oxycodone hydrochloride capsules. There was also a statistical difference between most of the Higuchi dissolution constants for the different-strength slow-release capsules and most slow-release capsules and equivalent strength controlled-release manufactured tablets (P less than 0.05). Using 40% Methocel E4M Premium slowed the release of morphine sulfate and oxycodone hydrochloride from extemporaneously compounded capsules. The in vitro performance of the slow-release capsules showed little intrabatch variation

  4. Capsule Formulation of Ethanolic Extract of Pasak Bumi (Eurycoma Longifolia Jack., and its Effect on Human Health Vital Signs

    Directory of Open Access Journals (Sweden)

    Laela Hayu Nurani

    2017-08-01

    cover the bitter taste of E. longifolia. Clinical trials in this study use design pre-post treatment in healthy humans. Subjects used were male - healthy men and healthy women who met inclusion criteria and were subjected with formulated capsule for 14 days. The study resulted capsule formula comprising of the ethanolic extract of E. longifolia 300 mg, vivapur 101 300 mg, 58 mg maydis starch, aerosil 3%, talc 2%, and Mg stearate 1%. The results showed that the capsule of E. longifolia did not affect the value of heart rate, respiration rate, body temperature and weight (P > 0.05, based on paired t-test, but they causes a decrease in blood pressure of healthy human. The ethanol extract of E. longifolia caused vasodilation of blood vessels that can be used in antihypertensive therapy.

  5. Capsule-Preserving Hydrodilatation With Corticosteroid Versus Corticosteroid Injection Alone in Refractory Adhesive Capsulitis of Shoulder: A Randomized Controlled Trial.

    Science.gov (United States)

    Lee, Doo-Hyung; Yoon, Seung-Hyun; Lee, Michael Y; Kwack, Kyu-Sung; Rah, Ueon Woo

    2017-05-01

    To determine whether capsule-preserved hydrodilatation with corticosteroid improves pain and function in patients with refractory adhesive capsulitis (AC) better than intra-articular corticosteroid injection (IACI) alone. Prospective randomized controlled study. University-affiliated tertiary care hospital. Subjects with primary AC (N=64) with shoulder pain level of visual analog scale (VAS) score ≥5, even after the initial administration of IACI alone. Participants randomly received ultrasound-guided IACI alone with 1mL of 40mg/mL triamcinolone acetonide and 3mL of 1% lidocaine (n=32) or ultrasound-guided capsule-preserved hydrodilatation with corticosteroid with a mixture of 1mL of 40mg/mL triamcinolone acetonide, 6mL of 1% lidocaine, and normative saline (n=32). The primary outcome measure was the Shoulder Pain and Disability Index score. Secondary outcomes were the VAS of shoulder pain level and angles of shoulder passive range of motion, including flexion, abduction, extension, external rotation, and internal rotation at pretreatment and weeks 3, 6, and 12 of posttreatment. There were no significant differences between the 2 groups in terms of demographic characteristics (age, sex, duration of symptoms, shoulder affected, and body mass index) at baseline. Repeated-measures analysis of variance showed significant effect of time in all outcome measurements in both groups. However, group-by-time interactions were not significantly different for any of the outcomes between groups. This study shows that compared with pretreatment, all outcome measures improved significantly in both groups by time; however, there was no significant difference between the 2 groups. Therefore, we recommend IACI alone over capsule-preserved hydrodilatation with corticosteroid when considering the corticosteroid injection as a secondary option after the initial IACI fails to improve symptoms for patients with refractory AC. Copyright © 2016 American Congress of Rehabilitation

  6. As praças dr. Augusto Silva e Leonardo Venerando Pereira, 1701 Lavras - MG, segundo a visão dos seus freqüentadores The park dr. Augusto Silva, Lavras - MG, according to viewpoint of its users

    Directory of Open Access Journals (Sweden)

    Alessandra Teixeira da Silva

    2008-12-01

    Full Text Available As praças públicas, além de contribuírem para o embelezamento das cidades, também desempenham uma função importante no contexto urbanístico ambiental. A Praça Dr. Augusto Silva, situada no município de Lavras, MG, também já foi chamada de Largo da Matriz, Praça Central e Jardim Municipal, que foi inaugurado oficialmente em 29 de novembro de 1908, quando passou a ter o nome de um ilustre médico lavrense. A praça Dr. Augusto Silva, possui atualmente, área de 7.552,65 m² e apresenta como prolongamento a praça Leonardo Venerando Pereira, com área atual de 2.041,72 m². Até 1940, esse prolongamento era denominado de Praça da Bandeira. Constatou-se, que desde o início da década de 1910, o local foi palco de grandes celebrações e encontros políticos e também foi muito freqüentado pela população. A Praça possui rica vegetação, onde se destacam uma centenária Tipuana (Tipuana tipu, diversos ipês (Tabebuia spp., palmeiras-imperiais (Roystonea oleracea. Objetivando-se avaliar a situação atual e usos, foi realizada uma avaliação, mediante análise quantitativa e pesquisa junto à população. Foram feitas uma série de avaliações referentes aos seguintes itens: aspectos urbanísticos, físicos e a vegetação. A pesquisa de opinião foi aplicada a aproximadamente 600 usuários, na própria praça, em dias da semana e horários diferentes, por meio de um questionário com perguntas diretas ao próprio entrevistado. Os dados coletados foram analisados estatisticamente utilizando o Software SPSS, de onde foram obtidas as freqüências porcentuais. A maior parte dos entrevistados julga a praça como um ponto de encontro entre amigos, onde contemplam a sua beleza e descansam. Por meio de pesquisa de opinião realizada com os usuários da praça, pôde-se identificar que se trata de um local muito freqüentado por várias faixas etárias, em diferentes períodos do dia. A praça Dr. Augusto Silva mostra-se de grande import

  7. Bowman Capsulitis Predicts Poor Kidney Allograft Outcome in T Cell-Mediated Rejection.

    Science.gov (United States)

    Gallan, Alexander J; Chon, W James; Josephson, Michelle A; Cunningham, Patrick N; Henriksen, Kammi J; Chang, Anthony

    2018-02-28

    Acute T cell-mediated rejection (TCMR) is an important cause of renal allograft loss. The Banff classification for tubulointerstitial (type I) rejection is based on the extent of both interstitial inflammation and tubulitis. Lymphocytes may also be present between parietal epithelial cells and Bowman capsules in this setting, which we have termed "capsulitis." We conducted this study to determine the clinical significance of capsulitis. We identified 42 patients from the pathology archives at the University of Chicago with isolated Banff type I TCMR from 2010-2015. Patient demographic data, Banff classification, and graft outcome measurements were compared between capsulitis and non-capsulitis groups using Mann-Whitney U test. Capsulitis was present in 26 (62%), and was more frequently seen in Banff IB than IA TCMR (88% vs 44%, P=.01). Patients with capsulitis had a higher serum creatinine at biopsy (4.6 vs 2.9mg/dL, P=.04) and were more likely to progress to dialysis (42% vs 13%, P=.06) with fewer recovering their baseline serum creatinine (12% vs 38%, P=.08). Patients with both Banff IA TCMR and capsulitis have clinical outcomes similar or possibly worse than Banff IB TCMR compared to those with Banff IA and an absence of capsulitis. Capsulitis is an important pathologic parameter in the evaluation of kidney transplant biopsies with potential diagnostic, prognostic, and therapeutic implications in the setting of TCMR. Copyright © 2018. Published by Elsevier Inc.

  8. Posterior capsule opacification.

    Science.gov (United States)

    Wormstone, I Michael; Wang, Lixin; Liu, Christopher S C

    2009-02-01

    Posterior Capsule Opacification (PCO) is the most common complication of cataract surgery. At present the only means of treating cataract is by surgical intervention, and this initially restores high visual quality. Unfortunately, PCO develops in a significant proportion of patients to such an extent that a secondary loss of vision occurs. A modern cataract operation generates a capsular bag, which comprises a proportion of the anterior and the entire posterior capsule. The bag remains in situ, partitions the aqueous and vitreous humours, and in the majority of cases, houses an intraocular lens. The production of a capsular bag following surgery permits a free passage of light along the visual axis through the transparent intraocular lens and thin acellular posterior capsule. However, on the remaining anterior capsule, lens epithelial cells stubbornly reside despite enduring the rigours of surgical trauma. This resilient group of cells then begin to re-colonise the denuded regions of the anterior capsule, encroach onto the intraocular lens surface, occupy regions of the outer anterior capsule and most importantly of all begin to colonise the previously cell-free posterior capsule. Cells continue to divide, begin to cover the posterior capsule and can ultimately encroach on the visual axis resulting in changes to the matrix and cell organization that can give rise to light scatter. This review will describe the biological mechanisms driving PCO progression and discuss the influence of IOL design, surgical techniques and putative drug therapies in regulating the rate and severity of PCO.

  9. Relative bioavailability of itraconazole from an extemporaneously prepared suspension and from the marketed capsules.

    Science.gov (United States)

    Christensen, K J; Gubbins, P O; Gurley, B J; Bowman, J L; Buice, R G

    1998-02-01

    The bioavailability of itraconazole from an extemporaneously prepared suspension was compared with its bioavailability from the commercially available capsules. Ten healthy volunteers were fed breakfast and were then randomly assigned to receive either 400 mg of itraconazole 40-mg/mL oral suspension or four 100-mg itraconazole capsules with 240 mL of water. They were not allowed to rest in a supine position for six hours, eat for four hours, or take any beverages for two hours post-dose. Blood samples were taken immediately after the subjects had eaten and at intervals up to 72 hours post-dose. Serum was separated and stored at -70 degrees C. Serum itraconazole and hydroxyitraconazole concentrations were measured by high-performance liquid chromatography. After 14 days, each subject was given the dosage form that he or she did not previously receive, and testing was repeated. Maximum concentration (Cmax) and time to reach maximum concentration (tmax) were determined, and the area under the serum concentration-versus-time curve from 0 to 72 hours (AUC0-72) was estimated. The suspension:capsule ratios of least-squares means for Cmax, tmax, and AUC0-72 for itraconazole were 0.15 (90% confidence interval [CI], 0.11-0.21), 0.95 (90% CI, 0.75-1.20), and 0.12 (9% CI, 0.06-0.23), respectively. The results for hydroxyitraconazole were similar: 0.19 (0.13-0.28), 0.95 (0.81-1.12), and 0.13 (0.07-0.23), respectively. The bioavailability of itraconazole from the extemporaneously prepared suspension is much lower than that from capsules.

  10. Effects of food on a gastrically degraded drug: azithromycin fast-dissolving gelatin capsules and HPMC capsules.

    Science.gov (United States)

    Curatolo, William; Liu, Ping; Johnson, Barbara A; Hausberger, Angela; Quan, Ernest; Vendola, Thomas; Vatsaraj, Neha; Foulds, George; Vincent, John; Chandra, Richa

    2011-07-01

    Commercial azithromycin gelatin capsules (Zithromax®) are known to be bioequivalent to commercial azithromycin tablets (Zithromax®) when dosed in the fasted state. These capsules exhibit a reduced bioavailability when dosed in the fed state, while tablets do not. This gelatin capsule negative food effect was previously proposed to be due to slow and/or delayed capsule disintegration in the fed stomach, resulting in extended exposure of the drug to gastric acid, leading to degradation to des-cladinose-azithromycin (DCA). Azithromycin gelatin capsules were formulated with "superdisintegrants" to provide fast-dissolving capsules, and HPMC capsule shells were substituted for gelatin capsule shells, in an effort to eliminate the food effect. Healthy volunteers were dosed with these dosage forms under fasted and fed conditions; pharmacokinetics were evaluated. DCA pharmacokinetics were also evaluated for the HPMC capsule subjects. In vitro disintegration of azithromycin HPMC capsules in media containing food was evaluated and compared with commercial tablets and commercial gelatin capsules. When the two fast-dissolving capsule formulations were dosed to fed subjects, the azithromycin AUC was 38.9% and 52.1% lower than after fasted-state dosing. When HPMC capsules were dosed to fed subjects, the azithromycin AUC was 65.5% lower than after fasted-state dosing. For HPMC capsules, the absolute fasting-state to fed-state decrease in azithromycin AUC (on a molar basis) was similar to the increase in DCA AUC. In vitro capsule disintegration studies revealed extended disintegration times for commercial azithromycin gelatin capsules and HPMC capsules in media containing the liquid foods milk and Ensure®. Interaction of azithromycin gelatin and HPMC capsules with food results in slowed disintegration in vitro and decreased bioavailability in vivo. Concurrent measurement of serum azithromycin and the acid-degradation product DCA demonstrates that the loss of azithromycin

  11. Modulation of active pharmaceutical material release from a novel 'tablet in capsule system' containing an effervescent blend.

    Science.gov (United States)

    Gohel, Mukesh C; Sumitra G, Manhapra

    2002-02-19

    The objective of the present study was to obtain programmed drug delivery from hard gelatin capsules containing a hydrophilic plug (HPMC or guar gum). The significance of factors such as type of plug (powder or tablet), plug thickness and the formulation of fill material on the release pattern of diltiazem HCl, a model drug, was investigated. The body portion of the hard gelatin capsules was cross-linked by the combined effect of formaldehyde and heat treatment. A linear relationship was observed between weight of HPMC K15M and log % drug released at 4 h from the capsules containing the plug in powder form. In order to accelerate the drug release after a lag time of 4 h, addition of an effervescent blend, NaHCO(3) and citric acid, in the capsules was found to be essential. The plugs of HPMC in tablet form, with or without a water soluble adjuvant (NaCl or lactose) were used for obtaining immediate drug release after the lag time. Sodium chloride did not cause significant influence on drug release whereas lactose favourably affected the drug release. The capsules containing HPMC K15M tablet plug (200 mg) and 35 mg effervescent blend in body portion of the capsule met the selection criteria of less than 10% drug release in 4 h and immediate drug release thereafter. It is further shown that the drug release was also dependant on the type of swellable hydrophilic agent (HPMC or guar gum) and molecular weight of HPMC (K15M or 20 cPs). The results reveal that programmed drug delivery can be obtained from hard gelatin capsules by systemic formulation approach.

  12. THE LICK/SDSS LIBRARY. II. [Ca/Fe] AND [Mg/Fe] IN F, G, AND K STARS FROM SDSS-DR7

    International Nuclear Information System (INIS)

    Franchini, M.; Morossi, C.; Di Marcantonio, P.; Malagnini, M. L.; Chavez, M.

    2011-01-01

    We analyzed the spectra of 17,600 F, G, and K stars extracted from the seventh Sloan Digital Sky Survey Data Release (SDSS-DR7) database in order to derive ([α/Fe]), [Ca/Fe], and [Mg/Fe] ratios. Particular attention has been devoted to estimating homogeneous and self-consistent atmospheric parameter values, T eff , log g, and [Fe/H], by comparing synthetic and observational Lick/SDSS indices. We present results for the sub-sample of more than 4000 spectra whose overall quality allowed us to derive fairly accurate stellar atmospheric parameter values and, therefore, reliable abundance ratios. A Monte Carlo approach was adopted to evaluate both the errors in the observational Lick/SDSS indices and in the derived parameter estimates. The analysis of the trends of [Ca/Fe] and [Mg/Fe] versus [Fe/H] pointed out that (1) the [Ca/Fe] and [Mg/Fe] ratios increase with decreasing [Fe/H] with different slopes reaching maximum average levels of +0.25 and +0.40 dex at [Fe/H] ≅ -1.75, respectively; (2) our sample contains, at a given [Fe/H], stars characterized by significantly different amounts of α-enhancement, thus belonging to different Galactic populations; and (3) the analyzed sample shows a predominance of thick disk stars for [Fe/H] > - 0.5 and the presence of stars belonging to the h igh-αhalo population for -2.0 < [Fe/H] <-0.5.

  13. Bioequivalence Studies of a Reformulated Dutasteride and Tamsulosin Hydrochloride Combination Capsule and a Commercially Available Formulation.

    Science.gov (United States)

    Kurczewski, Renee; Bowen, Chet; Collins, David; Zhu, John; Serbest, Gulyeter; Manyak, Michael

    2017-09-01

    A dutasteride 0.5 mg and tamsulosin hydrochloride 0.4 mg combination (DTC) capsule (Duodart ® ) was reformulated to reduce the capsule size and enhance product stability. Bioequivalence of the reformulated DTC capsule with the commercial formulation was evaluated in 2 single-dose, open-label, randomized, 2-way crossover studies in healthy adult male volunteers. Subjects in a fasted or fed state received a single oral dose of either the reformulated DTC or the commercial formulation followed by a 28-day washout period between treatments. Blood samples were taken predose and up to 72 hours postdose for pharmacokinetic (PK) analysis of dutasteride and tamsulosin serum concentrations. From the serum concentration-vs-time data, a noncompartmental method was used to calculate the maximum observed serum concentration (C max ) and area under the serum concentration-time curve (AUC 0-t ) for dutasteride and tamsulosin, and AUC 0-∞ for tamsulosin. The 90% confidence intervals for the ratios of the C max and AUC 0-t (for dutasteride and tamsulosin) and for AUC 0-∞ (for tamsulosin) were all completely contained within the range of 80% to 125%; therefore, the reformulated DTC capsule is bioequivalent to the commercial formulation under both fed and fasted states. © 2017, The American College of Clinical Pharmacology.

  14. Microstructure and degradation performance of biodegradable Mg-Si-Sr implant alloys.

    Science.gov (United States)

    Gil-Santos, Andrea; Marco, Iñigo; Moelans, Nele; Hort, Norbert; Van der Biest, Omer

    2017-02-01

    In this work the microstructure and degradation behavior of several as-cast alloy compositions belonging to the Mg rich corner of the Mg-Si-Sr system are presented and related. The intermetallic phases are identified and analyzed describing the microstructure evolution during solidification. It is intended in this work to obtain insight in the behavior of the ternary alloys in in vitro tests and to analyze the degradation behavior of the alloys under physiologically relevant conditions. The as-cast specimens have been exposed to immersion tests, both mass loss (ML) and potentiodynamic polarization (PDP). The degradation rate (DR) have been assessed and correlated to microstructure features, impurity levels and alloy composition. The initial reactions resulted to be more severe while the degradation stabilizes with time. A higher DR is related with a high content of the Mg 17 Sr 2 phase and with the presence of coarse particles of the intermetallics Mg 2 Si, MgSiSr and MgSi 2 Sr. Specimens with a higher DR typically have higher levels of impurities and alloy contents. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Status of the material capsule irradiation and the development of the new capsule technology in HANARO

    International Nuclear Information System (INIS)

    Choo, Kee-Nam; Kang, Young-Hwan; Choi, Myoung-Hwan; Cho, Man-Soon; Kim, Bong-Goo

    2006-01-01

    A material capsule system including a main capsule, fixing, control, cutting, and transport systems was developed for an irradiation test of non-fissile materials in HANARO. 14 irradiation capsules (12 instrumented and 2 non-instrumented capsules) have been designed, fabricated and successfully irradiated in the HANARO CT and IR test holes since 1995. The capsules were mainly designed for an irradiation of the RPV (Reactor Pressure Vessel), reactor core materials, and Zr-based alloys. Most capsules were made for KAERI material research projects, but 5 capsules were made as a part of national projects for the promotion of the HANARO utilization for universities. Based on the accumulated irradiation experience and the user's sophisticated requirements, development of new instrumented capsule technologies for a more precise control of the irradiation temperature and fluence of a specimen irrespective of the reactor operation has been performed in HANARO. (author)

  16. Formulation and statistical optimization of gastric floating alginate/oil/chitosan capsules loading procyanidins: in vitro and in vivo evaluations.

    Science.gov (United States)

    Chen, Rencai; Guo, Xiaomin; Liu, Xuecong; Cui, Haiming; Wang, Rui; Han, Jing

    2018-03-01

    The aim of the present work was to develop gastric floating capsules containing oil-entrapped beads loading procyanidins. The floating beads were prepared by ionotropic gelation method using sodium alginate, CaCl 2 and chitosan. The effect of three independent parameters (concentration of sodium alginate, CaCl 2 and chitosan) on entrapment efficiency were analyzed by Box-Behnken design. The floating beads were evaluated for surface morphology, particle size, density, entrapment efficiency, buoyancy, release behavior in vitro and floating ability in vivo. The prepared beads were grossly spherical in shape and the mean size was approximately 1.54±0.17mm. The density was 0.97g/cm 3 . And the optimal conditions were as follows: concentration of sodium alginate, CaCl 2 and chitosan were 33.75mg/mL, 9.84mg/mL and 9.05mg/mL, respectively. The optimized formulation showed entrapment efficiency of 88.84±1.04% within small error-value (0.65). The release mechanism of floating capsules followed Korsmeyer-Peppas model (r 2 =0.9902) with non-Fickian release. The gastric floating capsules exhibited 100% floating percentage in vitro and they could float on the top of gastric juice for 5h in vivo. Therefore, the floating capsules are able to prolong the gastroretentive delivery of procyanidins. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. The DR 3 reactor at Risoe, Denmark and its associated hot cell facilities. Information sheets

    International Nuclear Information System (INIS)

    Hardt, P. von der; Roettger, H.

    1981-01-01

    Technical information is given on the DR 2 reactor and associated hot cell facilities, with the main emphasis on experimental irradiation facilities, specialized irradiation devices (loops and capsules) and possibilities for post-irradiation examinations of samples. The information is presented in the form of seven information sheets under the headings: main characteristics of the reactor; utilization and specialization of the reactor; experimental facilities; main characteristics of specialized irradiation devices; main characteristics of hot cell facilities; equipment and techniques available for post-irradiation examinations; utilization and specialization of the hot cell facilities

  18. Summary Report for Capsule Dry Storage Project

    Energy Technology Data Exchange (ETDEWEB)

    JOSEPHSON, W S

    2003-09-04

    There are 1.936 cesium (Cs) and strontium (Sr) capsules stored in pools at the Waste Encapsulation and Storage Facility (WESF). These capsules will be moved to dry storage on the Hanford Site as an interim measure to reduce risk. The Cs/Sr Capsule Dry Storage Project (CDSP) is conducted under the assumption the capsules will eventually be moved to the repository at Yucca Mountain, and the design criteria include requirements that will facilitate acceptance at the repository. The storage system must also permit retrieval of capsules in the event vitrification of the capsule contents is pursued. A cut away drawing of a typical cesium chloride (CsCI) capsule and the capsule property and geometry information are provided in Figure 1.1. Strontium fluoride (SrF{sub 2}) capsules are similar in design to CsCl capsules. Further details of capsule design, current state, and reference information are given later in this report and its references. Capsule production and life history is covered in WMP-16938, Capsule Characterization Report for Capsule Dry Storage Project, and is briefly summarized in Section 5.2 of this report.

  19. Analytical Model for the Probability Characteristics of a Crack Penetrating Capsules in Capsule-Based Self-Healing Cementitious Materials

    Directory of Open Access Journals (Sweden)

    Zhong LV

    2017-08-01

    Full Text Available Autonomous crack healing using pre-embedded capsules containing healing agent is becoming a promising approach to restore the strength of damaged structures. In addition to the material properties, the size and volume fraction of capsules influence crack healing in the matrix. Understanding the crack and capsule interaction is critical in the development and design of structures made of capsule-based self-healing materials. Continuing our previous study, in this contribution a more practical rupturing mode of capsules characterizing the rupturing manner of capsules fractured by cracks in cementitious materials is presented, i.e., penetrating mode. With the underlying assumption that a crack penetrating capsules undoubtedly leads to crack healing, geometrical probability theory is employed to develop the quantitative relationship between crack size and capsule size, capsule concentration in capsule-based self-healing virtual cementitious material. Moreover, an analytical expression of probability of a crack penetrating with randomly dispersed capsules is developed in two-dimensional material matrix setup. The influences of the induced rupturing modes of capsules embedded on the self-healing efficiency are analyzed. Much attention is paid to compare the penetrating probability and the hitting probability, in order to assist the designer to make a choice of the optimal rupturing modes of capsules embedded. The accuracy of results of the theoretical model is also compared with Monte-Carlo numerical analysis of crack interacting with capsules. It shows that the developed probability characteristics of a crack interaction with capsules for different rupturing modes is helpful to provide guidelines for designer working with capsule-based self-healing cementitious materials.DOI: http://dx.doi.org/10.5755/j01.ms.23.3.16888

  20. Reinforcing effects of caffeine in coffee and capsules.

    OpenAIRE

    Griffiths, R R; Bigelow, G E; Liebson, I A

    1989-01-01

    In a residential research ward the reinforcing and subjective effects of caffeine were studied under double-blind conditions in volunteer subjects with histories of heavy coffee drinking. In Experiment 1, 6 subjects had 13 opportunities each day to self-administer either a caffeine (100 mg) or a placebo capsule for periods of 14 to 61 days. All subjects developed a clear preference for caffeine, with intake of caffeine becoming relatively stable after preference had been attained. Preference ...

  1. Absorption and subjective effects of caffeine from coffee, cola and capsules.

    Science.gov (United States)

    Liguori, A; Hughes, J R; Grass, J A

    1997-11-01

    Coffee is often perceived as producing greater pharmacological effects than cola. The present study compared the magnitude and rapidity of peak caffeine levels and subjective effects between coffee and cola. Thirteen users of both coffee and cola (mean daily caffeine consumption = 456 mg) ingested 400 mg caffeine via 12 oz unsweetened coffee, 24 oz sugar-free cola or 2 capsules in a random, double-blind, placebo-controlled, within-subjects design. Subjects provided a saliva sample and completed subjective effect scales 15 min before and 30, 60, 90, 120, 180 and 240 min after ingestion. Mean peak saliva caffeine levels did not differ between coffee (9.7 +/- 1.2 micrograms/ml) and cola (9.8 +/- 0.9 micrograms/ml) and appeared to be greater with these beverages than with the capsule (7.8 +/- 0.6 micrograms/ml; p = NS). Saliva caffeine levels peaked at similar times for coffee (42 +/- 5 min) and cola (39 +/- 5 min) but later for capsule (67 +/- 7 min; p = 0.004). There was no main effect of vehicle or interaction of vehicle and drug on magnitude of peak effect or time to peak increase on self-report scales. In summary, peak caffeine absorption, time to peak absorption, and subjective effects do not appear to be influenced by cola vs. coffee vehicle. Perceived differences in the effects of coffee vs. cola may be due to differences in dose, time of day, added sweetener, environmental setting or contingencies.

  2. Polydopamine-coated capsules

    Science.gov (United States)

    White, Scott R.; Sottos, Nancy R.; Kang, Sen; Baginska, Marta B.

    2018-04-17

    One aspect of the invention is a polymer material comprising a capsule coated with PDA. In certain embodiments, the capsule encapsulates a functional agent. The encapsulated functional agent may be an indicating agent, healing agent, protecting agent, pharmaceutical drug, food additive, or a combination thereof.

  3. Analysis and radiation dose rate measurement of the Al-1050 capsule on the rabbit system facility

    International Nuclear Information System (INIS)

    Sarwani; Sutrisno; H, Saleh; Rohidi; M, Kawkab

    2000-01-01

    Aluminium is a kind of light metal with density of 2.7 gram /cm exp 3,regarding to the aluminium is characteristic such as easy to fabricated,has a good corrosion resistant and radiation heat resistant, therefore aluminum is selected to be used as a material for sample irradiation capsule with high neutron fluency. Analysis using neutron activation method and capsule irradiation by using high neutron fluency and dose radiation rate measurement was done. The analysis result show that impurities in the Al-1050 capsule are Fe, Cu, Mg, Sb, Zn, and Mn. The capsule irradiated at 15 MW during 6 Hours with neutron fluency of 2,8 x 10 exp 17 n/cm exp 2. The radiation doses rate after 24 hours decay is 220 mrad/h at 0-meter distance and 60 mrad/h at 1-meter distance. Respectively. From the analysis results and measurement show that the Al-1050 capsule has no high neutron absorption element and available to get continuing irradiation at 15 MW as far as 6 hours. Due to the personal safety, therefore the capsule handling could be carried out in the hot cell

  4. Study of a low-dose capsule filling process by dynamic and static tests for advanced process understanding.

    Science.gov (United States)

    Stranzinger, S; Faulhammer, E; Scheibelhofer, O; Calzolari, V; Biserni, S; Paudel, A; Khinast, J G

    2018-04-05

    Precise filling of capsules with doses in the mg-range requires a good understanding of the filling process. Therefore, we investigated the various process steps of the filling process by dynamic and static mode tests. Dynamic tests refer to filling of capsules in a regular laboratory dosator filling machine. Static tests were conducted using a novel filling system developed by us. Three grades of lactose excipients were filled into size 3 capsules with different dosing chamber lengths, nozzle diameters and powder bed heights, and, in the dynamic mode, with two filling speeds (500, 3000 caps/h). The influence of the gap at the bottom of the powder container on the fill weight and variability was assessed. Different gaps resulted in a change in fill weight in all materials, although in different ways. In all cases, the fill weight of highly cohesive Lactohale 220 increased when decreasing the gap. Furthermore, experiments with the stand-alone static test tool indicated that this very challenging powder could successfully be filled without any pre-compression in the range of 5 mg-20 mg with acceptable RSDs. This finding is of great importance since for very fine lactose powders high compression ratios (dosing-chamber-length-to-powder-bed height compression ratios) may result in jamming of the piston. Moreover, it shows that the static mode setup is suitable for studying fill weight and variability. Since cohesive powders, such as Lactohale 220, are hard to fill, we investigated the impact of vibration on the process. Interestingly, we found no correlation between the reported fill weight changes in dynamic mode at 3000 cph and static mode using similar vibration. However, we could show that vibrations during sampling in the static mode dramatically reduced fill weight variability. Overall, our results indicate that by fine-tuning instrumental settings even very challenging powders can be filled with a low-dose dosator capsule filling machine. This study is a

  5. Hot cell examination on the surveillance capsule and HANARO capsule in IMEF

    International Nuclear Information System (INIS)

    Choo, Yong Sun; Oh, Wan Ho; Yoo, Byung Ok; Jung, Yang Hong; Ahn, Sang Bok; Baik, Seung Je; Song, Wung Sup; Hong, Kwon Pyo

    2000-01-01

    For the maintenance of integrity and safety of pressurizer of commercial power plant until its life span, it is required by US NRC 10CFR50 APP. G and H and ASTM E185-94 to periodically monitor irradiation embrittlement by neutron irradiation. In order to accomplished the requirement reactor operator has been carrying out the test by extracting the monitoring capsule embeded in reactor during the period of planned preventive maintenance. In relation to this irradiation samples are being used for prediction of reactor vessel life span and reactor vessel's adjusted reference temperature by irradiation of neutron flux enough to reach to end of life span. And also irradiation capsules with and without instrumentation are used for R and D on nuclear materials. Each capsule contains high radioactivity, therefore, post irradiation examination has to be handled by all means in the hot cell. The facility available for this purpose is Irradiated material examination facility (IMEF) to handle such works as capsule receiving, capsule cut and dismantling, sample classification, various examination, and finally development and improvement of examination equipment and instrumentation. (Hong, J. S.)

  6. Passive sorting of capsules by deformability

    Science.gov (United States)

    Haener, Edgar; Juel, Anne

    We study passive sorting according to deformability of liquid-filled ovalbumin-alginate capsules. We present results for two sorting geometries: a straight channel with a half-cylindrical obstruction and a pinched flow fractioning device (PFF) adapted for use with capsules. In the half-cylinder device, the capsules deform as they encounter the obstruction, and travel around the half-cylinder. The distance from the capsule's centre of mass to the surface of the half-cylinder depends on deformability, and separation between capsules of different deformability is amplified by diverging streamlines in the channel expansion downstream of the obstruction. We show experimentally that capsules can be sorted according to deformability with their downstream position depending on capillary number only, and we establish the sensitivity of the device to experimental variability. In the PFF device, particles are compressed against a wall using a strong pinching flow. We show that capsule deformation increases with the intensity of the pinching flow, but that the downstream capsule position is not set by deformation in the device. However, when using the PFF device like a T-Junction, we achieve improved sorting resolution compared to the half-cylinder device.

  7. Magnetically guided capsule endoscopy.

    Science.gov (United States)

    Shamsudhin, Naveen; Zverev, Vladimir I; Keller, Henrik; Pane, Salvador; Egolf, Peter W; Nelson, Bradley J; Tishin, Alexander M

    2017-08-01

    Wireless capsule endoscopy (WCE) is a powerful tool for medical screening and diagnosis, where a small capsule is swallowed and moved by means of natural peristalsis and gravity through the human gastrointestinal (GI) tract. The camera-integrated capsule allows for visualization of the small intestine, a region which was previously inaccessible to classical flexible endoscopy. As a diagnostic tool, it allows to localize the sources of bleedings in the middle part of the gastrointestinal tract and to identify diseases, such as inflammatory bowel disease (Crohn's disease), polyposis syndrome, and tumors. The screening and diagnostic efficacy of the WCE, especially in the stomach region, is hampered by a variety of technical challenges like the lack of active capsular position and orientation control. Therapeutic functionality is absent in most commercial capsules, due to constraints in capsular volume and energy storage. The possibility of using body-exogenous magnetic fields to guide, orient, power, and operate the capsule and its mechanisms has led to increasing research in Magnetically Guided Capsule Endoscopy (MGCE). This work shortly reviews the history and state-of-art in WCE technology. It highlights the magnetic technologies for advancing diagnostic and therapeutic functionalities of WCE. Not restricting itself to the GI tract, the review further investigates the technological developments in magnetically guided microrobots that can navigate through the various air- and fluid-filled lumina and cavities in the body for minimally invasive medicine. © 2017 American Association of Physicists in Medicine.

  8. Development and validation of a dissolution test for diltiazem hydrochloride in immediate release capsules

    Directory of Open Access Journals (Sweden)

    Taciane Ferreira Mendonça

    2011-01-01

    Full Text Available This work describes the development and validation of a dissolution test for 60 mg of diltiazem hydrochloride in immediate release capsules. The best dissolution in vitro profile was achieved using potassium phosphate buffer at pH 6.8 as the dissolution medium and paddle as the apparatus at 50 rpm. The drug concentrations in the dissolution media were determined by UV spectrophotometry and HPLC and a statistical analysis revealed that there were significant differences between HPLC and spectrophotometry. This study illustrates the importance of an official method for the dissolution test, since there is no official monograph for diltiazem hydrochloride in capsules.

  9. Dr Luigi Orlando, Dr Sergio Ceccuzzi, Dr. Armando Sbrana, Europa Metalli, Italy, Dr Albert Scherger, Member of KM Europa Metal AG, Osnabr ck, Germany, Prof. Filippo Menzinger, Scientific Attaché, Permanent Mission of Italy in Geneva

    CERN Multimedia

    Patrice Loïez

    2001-01-01

    Photo 01: Dr Lyn Evans and Dr Luigi Orlando Photo 04: L. to r.: Dr Lyn Evans, Dr Luigi Orlando, Prof. Luciano Maiani and Prof. Filippo Menzinger Photo 06: L. to r.: Prof. Philippo Menzinger, Dr Armando Sbrana, Prof. Luciano Maiani, Dr Albert Scherger, Dr Lyn Evans, Dr Luigi Orlando, Dr Sergio Ceccuzzi, visiting the LHC superconducting magnet test hall, SM18

  10. Probing cell internalisation mechanics with polymer capsules.

    Science.gov (United States)

    Chen, Xi; Cui, Jiwei; Ping, Yuan; Suma, Tomoya; Cavalieri, Francesca; Besford, Quinn A; Chen, George; Braunger, Julia A; Caruso, Frank

    2016-10-06

    We report polymer capsule-based probes for quantifying the pressure exerted by cells during capsule internalisation (P in ). Poly(methacrylic acid) (PMA) capsules with tuneable mechanical properties were fabricated through layer-by-layer assembly. The P in was quantified by correlating the cell-induced deformation with the ex situ osmotically induced deformation of the polymer capsules. Ultimately, we found that human monocyte-derived macrophage THP-1 cells exerted up to approximately 360 kPa on the capsules during internalisation.

  11. Comparison of the Efficacy of Two Vaginal Progesterone Formulations, Crinone 8% Gel and Utrogestan Capsules, Used for Luteal Support in Blastocyst Stage Embryo Transfers

    Directory of Open Access Journals (Sweden)

    Li-Jung Wang

    2009-12-01

    Conclusion: Luteal phase support with Crinone 8% vaginal gel (90 mg daily resulted in better clinical pregnancy and implantation rates than Utrogestan vaginal capsules (200 mg, 4 times daily in IVF/ICSI–BT cycles.

  12. Ocular myasthenia gravis induced by human acetylcholine receptor ϵ subunit immunization in HLA DR3 transgenic mice.

    Science.gov (United States)

    Wu, Xiaorong; Tuzun, Erdem; Saini, Shamsher S; Wang, Jun; Li, Jing; Aguilera-Aguirre, Leopoldo; Huda, Ruksana; Christadoss, Premkumar

    2015-12-01

    Extraocular muscles (EOM) are preferentially involved in myasthenia gravis (MG) and acetylcholine receptor (AChR) antibody positive MG patients may occasionally present with isolated ocular symptoms. Although experimental autoimmune myasthenia gravis (EAMG) induced by whole AChR immunization closely mimics clinical and immunopathological aspects of MG, EOM are usually not affected. We have previously developed an EAMG model, which imitates EOM symptoms of MG by immunization of human leukocyte antigen (HLA) transgenic mice with α or γ-subunits of human AChR (H-AChR). To investigate the significance of the ϵ-subunit in ocular MG, we immunized HLA-DR3 and HLA-DQ8 transgenic mice with recombinant H-AChR ϵ-subunit expressed in Escherichia coli. HLA-DR3 transgenic mice showed significantly higher clinical ocular and generalized MG severity scores and lower grip strength values than HLA-DQ8 mice. H-AChR ϵ-subunit-immunized HLA-DR3 transgenic mice had higher serum anti-AChR antibody (IgG, IgG1, IgG2b, IgG2c and IgM) levels, neuromuscular junction IgG and complement deposit percentages than ϵ-subunit-immunized HLA-DQ8 transgenic mice. Control mice immunized with E. coli extract or complete Freund adjuvant (CFA) did not show clinical and immunopathological features of ocular and generalized EAMG. Lymph node cells of ϵ-subunit-immunized HLA-DR3 mice showed significantly higher proliferative responses than those of ϵ-subunit-immunized HLA-DQ8 mice, crude E. coli extract-immunized and CFA-immunized transgenic mice. Our results indicate that the human AChR ϵ-subunit is capable of inducing myasthenic muscle weakness. Diversity of the autoimmune responses displayed by mice expressing different HLA class II molecules suggests that the interplay between HLA class II alleles and AChR subunits might have a profound impact on the clinical course of MG. Copyright © 2015 European Federation of Immunological Societies. Published by Elsevier B.V. All rights reserved.

  13. Domperidone prolongs oral to duodenal transit time in video capsule endoscopy.

    Science.gov (United States)

    Mcfarlane, Michael; Liu, B; Nwokolo, C

    2018-04-01

    Domperidone is thought to accelerate gastric emptying via D2 receptor antagonism at the gastro-oesophageal and gastro-duodenal junctions. Listed in the BNF as a prokinetic anti-emetic, it has been used in video capsule endoscopy (VCE) to accelerate capsule delivery to the small intestine. We audited VCEs performed at UHCW from 2011, when as standard practice, domperidone was given pre-VCE, to 2012, after its discontinuation due to doubts about its effectiveness. Thirty-one patients received oral domperidone 20 mg pre-VCE. Thirty-three patients underwent VCE without domperidone pre-treatment. After 2 h, if the capsule remained intra-gastric, gastroscopy-assisted duodenal delivery was performed. Data was analysed using Mann-Whitney testing. Median oro-duodenal transit was 13 and 30 min in the untreated and domperidone groups, respectively (p = 0.01). Median oro-caecal transit was 242 and 267 min in the untreated and domperidone groups, respectively (p = 0.02). No difference in duodenal-caecal transit was seen (p = 0.60). Six percent of untreated and 13% of domperidone VCEs required gastroscopy-assisted duodenal capsule delivery (p = 0.65). Unexpectedly domperidone delayed VCE gastric transit. Most studies on domperidone prokinetic effects have been in diabetic gastroparesis, demonstrating that domperidone can achieve good symptomatic relief, but with mixed results for gastric emptying. Our study suggests that any antiemetic effects of domperidone are not mediated through accelerated gastric transit.

  14. Assessing the use of food coloring as an appropriate visual guide for homogenously mixed capsule powders in extemporaneous compounding.

    Science.gov (United States)

    Hoffmann, Brittany; Carlson, Christie; Rao, Deepa A

    2014-01-01

    The purpose of this work was to assess the use of food colors as a visual aid to determine homogeneous mixing in the extemporaneous preparation of capsules. Six different batches of progesterone slow-release 200-mg capsules were prepared by different mixing methods until visually determined as homogeneous based on yellow food coloring distribution in the preparation by the Central Iowa Compounding Pharmacy, Des Moines, Iowa. UV-Vis spectrophotometry was used to extract and evaluate yellow food coloring content in each of these batches and compared to an in-house, small-batch geometric dilution preparation of progesterone slow- release 200-mg capsules. Of the 6 batches tested, only one, which followed the principles of additive dilution and an appropriate mixing time, was both visually and quantitatively homogeneous in the detection of yellow food coloring. The use of food coloring alone is not a valid quality-assurance tool in determining homogeneous mixing. Principles of geometric and/or additive dilution and appropriate mixing times along with the food color can serve as a quality-assurance tool.

  15. Dræb, dræb, dræb! Nej ... liiiige et øjeblik: De machiavelliske følelser i Game of Thrones

    DEFF Research Database (Denmark)

    Schubart, Rikke

    2013-01-01

    Blogindlæg om Machiavelliske følelser i HBO tv-serien Game of Thrones: "Dræb, dræb, dræb! Nej ... liiiige et øjeblik: De machiavelliske følelser i Game of Thrones"......Blogindlæg om Machiavelliske følelser i HBO tv-serien Game of Thrones: "Dræb, dræb, dræb! Nej ... liiiige et øjeblik: De machiavelliske følelser i Game of Thrones"...

  16. 77 FR 53892 - Determination That ALOXI (Palonosetron Hydrochloride) Capsules, 0.5 Milligram (Base), Were Not...

    Science.gov (United States)

    2012-09-04

    ... discontinued from marketing for reasons other than safety or effectiveness. ANDAs that refer to ALOXI... Sale for Reasons of Safety or Effectiveness AGENCY: Food and Drug Administration, HHS. ACTION: Notice...)) Capsules, 0.5 milligram (mg) (base), were not withdrawn from sale for reasons of safety or effectiveness...

  17. Status of irradiation capsule design

    International Nuclear Information System (INIS)

    Nagata, Hiroshi; Yamaura, Takayuki; Nagao, Yoshiharu

    2013-01-01

    For the irradiation test after the restart of JMTR, further precise temperature control and temperature prediction are required. In the design of irradiation capsule, particularly sophisticated irradiation temperature prediction and evaluation are urged. Under such circumstance, among the conventional design techniques of irradiation capsule, the authors reviewed the evaluation method of irradiation temperature. In addition, for the improvement of use convenience, this study examined and improved FINAS/STAR code in order to adopt the new calculation code that enables a variety of analyses. In addition, the study on the common use of the components for radiation capsule enabled the shortening of design period. After the restart, the authors will apply this improved calculation code to the design of irradiation capsule. (A.O.)

  18. [Efficacy and safety of Saw Palmetto Extract Capsules in the treatment of benign prostatic hyperplasia].

    Science.gov (United States)

    Ju, Xiao-bing; Gu, Xiao-jian; Zhang, Zheng-yu; Wei, Zhong-qing; Xu, Zhuo-qun; Miao, Hui-dong; Zhou, Wei-min; Xu, Ren-fang; Cheng, Bin; Ma, Jian-guo; Niu, Tian-li; Qu, Ping; Xue, Bo-xin; Zhang, Wei

    2015-12-01

    To assess the efficacy and safety of Saw Palmetto Extract Capsules in the treatment of benign prostatic hyperplasia (BPH). We conducted a multi-centered open clinical study on 165 BPH patients treated with Saw Palmetto Extract Capsules at a dose of 160 mg qd for 12 weeks. At the baseline and after 6 and 12 weeks of medication, we compared the International Prostate Symptom Scores (IPSS), prostate volume, postvoid residual urine volume, urinary flow rate, quality of life scores (QOL), and adverse events between the two groups of patients. Compared with the baseline, both IPSS and QOL were improved after 6 weeks of medication, and at 12 weeks, significant improvement was found in IPSS, QOL, urinary flow rate, and postvoid residual urine. Mild stomachache occurred in 1 case, which necessitated no treatment. Saw Palmetto Extract Capsules were safe and effective for the treatment of BPH.

  19. Intrauterine fertilization capsules--a clinical trial

    DEFF Research Database (Denmark)

    Lenz, S; Lindenberg, S; Sundberg, K

    1991-01-01

    Treatment of 26 women with tubal infertility was attempted using intrauterine capsules loaded with oocytes and spermatozoa. The stimulation protocol was as used for in vitro fertilization and embryo transfer and consisted of short-term use of Buserelin, human menopausal gonadotropin, and human...... and piston from an intrauterine device. Six complete capsules and parts of two other capsules were expelled. None of the women became pregnant, compared with a pregnancy rate of 21% per aspiration following in vitro fertilization and embryo transfer during the same period....... chorionic gonadotropin. Oocytes were collected by ultrasonically guided transvaginal aspiration, and spermatozoa were prepared by swim-up technique. The gametes were placed in agar capsules 4 hr after oocyte collection, and the capsules were introduced to the uterine fundus using an insertion tube...

  20. Zingiber officinale, Piper retrofractum and Combination Induced Apoptosis and p53 Expression in Myeloma and WiDr Cell Lines

    Directory of Open Access Journals (Sweden)

    HENY EKOWATI

    2012-09-01

    Full Text Available In previous studies, Zingiber officinale, Piper retrofractum, and the combination showed cytotoxic activity, induced apoptosis, and p53 expression of HeLa, T47D, and MCF-7 cell lines. This study was conducted to investigate the cytotoxic and apoptotic activity of Zingiber officinale (ZO, Piper retrofractum (PR, and the combination as well as their effect to p53 expression on Myeloma and WiDr cells. The powder of ZO, PR, and ZO + PR combination (1:1 were macerated with 96% ethanol for 3 x 24 hours. MTT cytotoxic assay was performed on Myeloma and WiDr cell lines. Apoptotic cells were stained with ethidium bromide and acridine orange. Imunohistochemical expression of p53 was examined on Myeloma and WiDr cell lines. Doxorubicin was used as positive control in all assays. Results showed that ZO, PR, and ZO + PR combination had cytotoxic activity on Myeloma cells with IC50 of 28, 36, and 55 mg/ml respectively and WiDr cell lines with IC50 of 74, 158, and 64 mg/ml respectively, induced apoptotic activity, and increased p53 expression on Myeloma and WiDr cells. These results suggest that ZO, PR, and their combination induced Myeloma and WiDr cells in apoptosis through p53 expression.

  1. Thermoregulation of Capsule Production by Streptococcus pyogenes

    Science.gov (United States)

    Kang, Song Ok; Wright, Jordan O.; Tesorero, Rafael A.; Lee, Hyunwoo; Beall, Bernard; Cho, Kyu Hong

    2012-01-01

    The capsule of Streptococcus pyogenes serves as an adhesin as well as an anti-phagocytic factor by binding to CD44 on keratinocytes of the pharyngeal mucosa and the skin, the main entry sites of the pathogen. We discovered that S. pyogenes HSC5 and MGAS315 strains are further thermoregulated for capsule production at a post-transcriptional level in addition to the transcriptional regulation by the CovRS two-component regulatory system. When the transcription of the hasABC capsular biosynthetic locus was de-repressed through mutation of the covRS system, the two strains, which have been used for pathogenesis studies in the laboratory, exhibited markedly increased capsule production at sub-body temperature. Employing transposon mutagenesis, we found that CvfA, a previously identified membrane-associated endoribonuclease, is required for the thermoregulation of capsule synthesis. The mutation of the cvfA gene conferred increased capsule production regardless of temperature. However, the amount of the capsule transcript was not changed by the mutation, indicating that a post-transcriptional regulator mediates between CvfA and thermoregulated capsule production. When we tested naturally occurring invasive mucoid strains, a high percentage (11/53, 21%) of the strains exhibited thermoregulated capsule production. As expected, the mucoid phenotype of these strains at sub-body temperature was due to mutations within the chromosomal covRS genes. Capsule thermoregulation that exhibits high capsule production at lower temperatures that occur on the skin or mucosal surface potentially confers better capability of adhesion and invasion when S. pyogenes penetrates the epithelial surface. PMID:22615992

  2. NIF capsule performance modeling

    Directory of Open Access Journals (Sweden)

    Weber S.

    2013-11-01

    Full Text Available Post-shot modeling of NIF capsule implosions was performed in order to validate our physical and numerical models. Cryogenic layered target implosions and experiments with surrogate targets produce an abundance of capsule performance data including implosion velocity, remaining ablator mass, times of peak x-ray and neutron emission, core image size, core symmetry, neutron yield, and x-ray spectra. We have attempted to match the integrated data set with capsule-only simulations by adjusting the drive and other physics parameters within expected uncertainties. The simulations include interface roughness, time-dependent symmetry, and a model of mix. We were able to match many of the measured performance parameters for a selection of shots.

  3. Herniation of the anterior lens capsule

    Directory of Open Access Journals (Sweden)

    Pereira Nolette

    2007-01-01

    Full Text Available Herniation of the anterior lens capsule is a rare abnormality in which the capsule bulges forward in the pupillary area. This herniation can be mistaken for an anterior lenticonus where both the capsule and the cortex bulge forward. The exact pathology behind this finding is still unclear. We report the clinical, ultrasound biomicroscopy (UBM and histopathological findings of a case of herniation of the anterior lens capsule. UBM helped to differentiate this entity from anterior lenticonus. Light microscopy revealed capsular splitting suggestive of capsular delamination and collection of fluid (aqueous in the area of herniation giving it a characteristic appearance.

  4. Diagnostic and therapeutic radio pharmaceutical capsules

    International Nuclear Information System (INIS)

    Haney, T.A.; Wedeking, P.W.; Morcos, N.A.

    1981-01-01

    An improved pharmaceutical radioactive capsule consisting of a non-toxic, water soluble material adapted to being ingested and rapidly disintegrating on contact with fluids of the gastro-intestinal tract is described. Each capsule is provided with filler material supporting a pharmaceutically useful radioactive compound absorbable from the gastro-intestinal tract. The capsule is preferably of gelatin, methyl cellulose or polyvinyl alcohol and the filler is a polyethylene glycol. The radioactive compound may be iodine e.g. sodium radioiodide I-131 or 123. The capsule may also contain a reducing agent e.g. sodium thiosulphate, sulphite, or bisulphite. (author)

  5. Increasing Z-pinch vacuum hohlraum capsule coupling efficiency

    International Nuclear Information System (INIS)

    Callahan, Debbie; Vesey, Roger Alan; Cochrane, Kyle Robert; Nikroo, A.; Bennett, Guy R.; Schroen, Diana Grace; Ruggles, Laurence E.; Porter, John L.; Streit, Jon; Mehlhorn, Thomas Alan; Cuneo, Michael Edward

    2004-01-01

    Symmetric capsule implosions in the double-ended vacuum hohlraum (DEH) on Z have demonstrated convergence ratios of 14-21 for 2.15-mm plastic ablator capsules absorbing 5-7 kJ of x-rays, based on backlit images of the compressed ablator remaining at peak convergence (1). Experiments with DD-filled 3.3-mm diameter capsules designed to absorb 14 kJ of x-rays have begun as an integrated test of drive temperature and symmetry, complementary to thin-shell symmetry diagnostic capsules. These capsule implosions are characterized by excellent control of symmetry (< 3% time-integrated), but low hohlraum efficiency (< 2%). Possible methods to increase the capsule absorbed energy in the DEH include mixed-component hohlraums, large diameter foam ablator capsules, transmissive shine shields between the z-pinch and capsule, higher spoke electrode x-ray transmission, a double-sided power feed, and smaller initial radius z-pinch wire arrays. Simulations will explore the potential for each of these modifications to increase the capsule coupling efficiency for near-term experiments on Z and ZR

  6. 21 CFR 520.1660b - Oxytetracycline hydrochloride capsules.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Oxytetracycline hydrochloride capsules. 520.1660b... Oxytetracycline hydrochloride capsules. (a) Specifications. The drug is in capsule form with each capsule containing 125 or 250 milligrams of oxytetracycline hydrochloride. Oxytetracycline is the antibiotic...

  7. Thermal characteristic test for saturated temperature type capsule

    International Nuclear Information System (INIS)

    Niimi, Motoji; Someya, Hiroyuki; Kobayashi, Toshiki; Ohuchi, Mitsuo; Harayama, Yasuo

    1989-08-01

    The Japan Material Testing Reactor Project is developing a new type capsule so-called 'Saturated Temperature Capsule', as a part of irradiation technique improvement program. This type capsule, in which the water is supplied and boiled, bases on the conception of keeping the coolant at the saturated temperature and facilitating the temperature setting of specimens heated by gamma-ray in reactor. However, out-pile test was planned, because there were few usable data for design and operation of the capsule into which the coolant was injected. A out-pile apparatus, simulated the capsule with electric heaters, was fabricated and experiments were carried out, to obtain data concerning design and operation for the capsule into which the water was injected. As a structure of simulated capsule, a type of downward coolant supply was adopted. The downward coolant tube type injectes the water in the bottom of capsule by tube through the upper flange. Major objects of experiences were to grasp thermal features under operation and to provide performances of capsule control equipment. Experimental results proved that the temperature of water within the capsule was easily varied by controlling supply water flow rate, and that the control equipment was operated stably and safety. (author)

  8. Capsule safety analysis of PRTF irradiation facility

    International Nuclear Information System (INIS)

    Suwarto

    2013-01-01

    Power Ramp Test Facility (PRTF) is an irradiation facility used for fuel testing of power reactor. PRTF has a capsule which is a test fuel rod container. During operation, pressurized water of 160 bars flows through in the capsule. Due to the high pressure it should be analyzed the impact of the capsule on reactor core safety. This analysis has purpose to calculate the ability of capsule pressure capacity. The analysis was carried out by calculating pressure capacity. From the calculating results it can be concluded that the capsule with pressure capacity of 438 bars will be safe to prevent the operation pressure of PRTF. (author)

  9. Relative bioavailability of diclofenac potassium from softgel capsule versus powder for oral solution and immediate-release tablet formulation.

    Science.gov (United States)

    Bende, Girish; Biswal, Shibadas; Bhad, Prafulla; Chen, Yuming; Salunke, Atish; Winter, Serge; Wagner, Robert; Sunkara, Gangadhar

    2016-01-01

    The oral bioavailability of diclofenac potassium 50 mg administered as a soft gelatin capsule (softgel capsule), powder for oral solution (oral solution), and tablet was evaluated in a randomized, open-label, 3-period, 6-sequence crossover study in healthy adults. Plasma diclofenac concentrations were measured using a validated liquid chromatography-mass spectrometry/mass spectrometry method, and pharmacokinetic analysis was performed by noncompartmental methods. The median time to achieve peak plasma concentrations of diclofenac was 0.5, 0.25, and 0.75 hours with the softgel capsule, oral solution, and tablet formulations, respectively. The geometric mean ratio and associated 90%CI for AUCinf, and Cmax of the softgel capsule formulation relative to the oral solution formulation were 0.97 (0.95-1.00) and 0.85 (0.76-0.95), respectively. The geometric mean ratio and associated 90%CI for AUCinf and Cmax of the softgel capsule formulation relative to the tablet formulation were 1.04 (1.00-1.08) and 1.67 (1.43-1.96), respectively. In conclusion, the exposure (AUC) of diclofenac with the new diclofenac potassium softgel capsule formulation was comparable to that of the existing oral solution and tablet formulations. The peak plasma concentration of diclofenac from the new softgel capsule was 67% higher than the existing tablet formulation, whereas it was 15% lower in comparison with the oral solution formulation. © 2015, The American College of Clinical Pharmacology.

  10. Adhesive capsulitis of the shoulder: MR arthrography

    International Nuclear Information System (INIS)

    Kim, Hyun Jeong; Han, Tae Il; Lee, Kwang Won; Choi, Youn Seon; Kim, Dae Hong; Han, Hyun Young; Song, Mun Kab; Kwon, Soon Tae

    2001-01-01

    Adhesive capsulitis is a clinical syndrome involving pain and decreased joint motion caused by thickening and contraction of the joint capsule. The purpose of this study is to describe the MR arthrographic findings of this syndrome. Twenty-nine sets of MR arthrographic images were included in the study. Fourteen patients had adhesive capsulitis diagnosed by physical examination and arthrography, and their MR arthrographic findings were compared with those of 15 subjects in the control group. The images were retrospectively reviewed with specific attention to the thickness of the joint capsule, volume of the axillary pouch (length, width, height(depth)), thinkness of the coracohumeral ligament, presence of extra-articular contrast extravasation, and contrst filling of the subcoracoid bursa. Mean capsular thickness measured at the inferior portion of the axillary pouch was 4.1 mm in patients with adhesive capsulitis and 1.5 mm in the control group. The mean width of the axillary pouch was 2.5 mm in patients and 9.5 mm in controls. In patients, the capsule was significantly thicker and the axillary pouch significantly narrower than in controls (p<0.05). Capsule thickness greater than 2.5 mm at the inferior portion of the axillary pouch (sensitivity 93%, specificity 80%) and a pouch narrower than 3.5 mm (sensitivity 93%, specificity 100%) were useful criteria for the diagnosis of adhesive capsulitis. In patients with this condition, extra-articular contrast extravasation was noted in six patients (43%) and contrast filling of the subcoracoid bursa in three (21%). The MR arthrographic findings of adhesive capsulitis are capsular thickening, a low-volume axillary pouch, extra-articular contrast extravasation, and contrast filling of the subcoracoid bursa. Capsule thickness greater than 2.5 mm at the inferior portion of the axillary pouch and a pouch width of less than 3.5 mm are useful diagnostic imaging characteristics

  11. Spectrophotometric Determination of Doxycycline Hyclate in Pure and Capsule using Diazotization Reaction

    Directory of Open Access Journals (Sweden)

    Ruba Fahmi Abbas

    2017-07-01

    Full Text Available A sensitive spectrophotometric method has been developed for the determination of Doxycycline hyclate (DCH as pure and  capsule forms. This method is based on diazotization of primary amine group of benzocaine with sodium nitrite in hydrochloric acid medium; the formed diazonium salt is then reacted with DCH in sodium hydroxide medium, to form yellow – orange Azo dye. Beer's law is obeyed in the concentration rang 16-34mg. ml-1 at 480 nm with detection limit LOD and molar absorptivity Є were found to be 0.418 mg.ml-1 and 2.214× 10+4 L.mol-1.cm-1, respectively.

  12. A New Family of Capsule Polymerases Generates Teichoic Acid-Like Capsule Polymers in Gram-Negative Pathogens.

    Science.gov (United States)

    Litschko, Christa; Oldrini, Davide; Budde, Insa; Berger, Monika; Meens, Jochen; Gerardy-Schahn, Rita; Berti, Francesco; Schubert, Mario; Fiebig, Timm

    2018-05-29

    Group 2 capsule polymers represent crucial virulence factors of Gram-negative pathogenic bacteria. They are synthesized by enzymes called capsule polymerases. In this report, we describe a new family of polymerases that combine glycosyltransferase and hexose- and polyol-phosphate transferase activity to generate complex poly(oligosaccharide phosphate) and poly(glycosylpolyol phosphate) polymers, the latter of which display similarity to wall teichoic acid (WTA), a cell wall component of Gram-positive bacteria. Using modeling and multiple-sequence alignment, we showed homology between the predicted polymerase domains and WTA type I biosynthesis enzymes, creating a link between Gram-negative and Gram-positive cell wall biosynthesis processes. The polymerases of the new family are highly abundant and found in a variety of capsule-expressing pathogens such as Neisseria meningitidis , Actinobacillus pleuropneumoniae , Haemophilus influenzae , Bibersteinia trehalosi , and Escherichia coli with both human and animal hosts. Five representative candidates were purified, their activities were confirmed using nuclear magnetic resonance (NMR) spectroscopy, and their predicted folds were validated by site-directed mutagenesis. IMPORTANCE Bacterial capsules play an important role in the interaction between a pathogen and the immune system of its host. During the last decade, capsule polymerases have become attractive tools for the production of capsule polymers applied as antigens in glycoconjugate vaccine formulations. Conventional production of glycoconjugate vaccines requires the cultivation of the pathogen and thus the highest biosafety standards, leading to tremendous costs. With regard to animal husbandry, where vaccines could avoid the extensive use of antibiotics, conventional production is not sufficiently cost-effective. In contrast, enzymatic synthesis of capsule polymers is pathogen-free and fast, offers high stereo- and regioselectivity, and works with high efficacy

  13. Oxygen fugacity and piston cylinder capsule assemblies

    Science.gov (United States)

    Jakobsson, S.

    2011-12-01

    A double capsule assembly designed to control oxygen fugacity in piston cylinder experiments has been tested at 1200 °C and 10 kbar. The assembly consists of an outer Pt-capsule containing a solid buffer (Ni-NiO or Co-CoO plus H2O) and an inner AuPd-capsule containing the sample, H2O and a Pt-wire. To prevent direct contact with the buffer phases the AuPd-capsule is embedded in finely ground Al2O3 along with some coarser, fractured Al2O3 facilitating fluid inclusion formation. No water loss is observed in the sample even after 48 hrs but a slight increase in water content is observed in longer duration runs due to oxygen and hydrogen diffusion into the AuPd-capsule. Carbon from the furnace also diffuses through the outer Pt-capsule but reacts with H2O in the outer capsule to form CO2 and never reaches the inner capsule. Oxygen fugacity of runs in equilibrium with the Ni-NiO and Co-CoO buffers was measured by analyzing the Fe content of the Pt-wire in the sample1 and by analyzing Fe dissolved in the AuPd capsule2. The second method gives values that are in good agreement with established buffer whereas results from the first method are one half to one log units higher than the established values. References 1. E. Medard, C. A. McCammon, J. A. Barr, T. L. Grove, Am. Mineral. 93, 1838 (2008). 2. J. Barr, T. Grove, Contrib. Mineral. Petrol. 160, 631 (2010)

  14. Vortex rings from Sphagnum moss capsules

    Science.gov (United States)

    Whitaker, Dwight; Strassman, Sam; Cha, Jung; Chang, Emily; Guo, Xinyi; Edwards, Joan

    2010-11-01

    The capsules of Sphagnum moss use vortex rings to disperse spores to suitable habitats many kilometers away. Vortex rings are created by the sudden release of pressurized air when the capsule ruptures, and are an efficient way to carry the small spores with low terminal velocities to heights where they can be carried by turbulent wind currents. We will present our computational model of these explosions, which are carried out using a 2-D large eddy simulation (LES) on FLUENT. Our simulations can reproduce the observed motion of the spore clouds observed from moss capsules with high-speed videos, and we will discuss the roles of bursting pressure, cap mass, and capsule morphology on the formation and quality of vortex rings created by this plant.

  15. [Evaluation of nopal capsules in diabetes mellitus].

    Science.gov (United States)

    Frati Munari, A C; Vera Lastra, O; Ariza Andraca, C R

    1992-01-01

    To find out if commercial capsules with dried nopal (prickle-pear cactus, Opuntia ficus indica may have a role in the management of diabetes mellitus, three experiments were performed: 30 capsules where given in fasting condition to 10 diabetic subjects and serum glucose was measured through out 3 hours; a control test was performed with 30 placebo capsules. OGTT with previous intake of 30 nopal or placebo capsules was performed in ten healthy individuals. In a crossover and single blinded study 14 diabetic patients withdrew the oral hypoglycemic treatment and received 10 nopal or placebo capsules t.i.d. during one week; serum glucose, cholesterol and tryglycerides levels were measured before and after each one-week period. Five healthy subjects were also studied in the same fashion. Opuntia capsules did not show acute hypoglycemic effect and did not influence OGTT. In diabetic patients serum glucose, cholesterol and tryglycerides levels did not change with Opuntia, but they increased with placebo (P nopal, while cholesterol and triglycerides decreased (P < 0.01 vs. placebo). The intake of 30 Opuntia capsules daily in patients with diabetes mellitus had a discrete beneficial effect on glucose and cholesterol. However this dose is unpractical and at present it is not recommended in the management of diabetes mellitus.

  16. Design and fabrication of non-instrumented capsule

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yong Sung; Lee, Jeong Young; Kim, Joon Yeon; Lee, Sung Ho; Ji, Dae Young; Kim, Suk Hoon; Ahn, Sung Ho [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1995-04-01

    The use of non-instrumented capsule designed and fabricated in this time is for the evaluation of material irradiation performance, it is to be installed in the inner core of HANARO. The design process of non-instrumented capsule was accomplished by the decision of the quality of material and the shape, thermal analysis, structural analysis. The temperature of the specimen and the stress in capsule during irradiation test was calculated by the thermal analysis and the structural analysis. GGENGTC code and ABAQUS code were used for the calculation of non-instrumented capsule. In case of installing the capsule in irradiation hole, the coolant flow rate and the pressure drop in the hole is changed, which will affect the coolant flow rate of the fuel region. Eventually the coolant flow rate outside capsule have to be restricted to the allowable range. In order to obtain the required pressure drop, the flow rate control mechanism, end plate and orifice ring were used in this test. The test results are compared with 36-element fuel pressure drop data which AECL performed by the SCTR facility.

  17. Design and fabrication of non-instrumented capsule

    International Nuclear Information System (INIS)

    Kim, Yong Sung; Lee, Jeong Young; Kim, Joon Yeon; Lee, Sung Ho; Ji, Dae Young; Kim, Suk Hoon; Ahn, Sung Ho

    1995-04-01

    The use of non-instrumented capsule designed and fabricated in this time is for the evaluation of material irradiation performance, it is to be installed in the inner core of HANARO. The design process of non-instrumented capsule was accomplished by the decision of the quality of material and the shape, thermal analysis, structural analysis. The temperature of the specimen and the stress in capsule during irradiation test was calculated by the thermal analysis and the structural analysis. GGENGTC code and ABAQUS code were used for the calculation of non-instrumented capsule. In case of installing the capsule in irradiation hole, the coolant flow rate and the pressure drop in the hole is changed, which will affect the coolant flow rate of the fuel region. Eventually the coolant flow rate outside capsule have to be restricted to the allowable range. In order to obtain the required pressure drop, the flow rate control mechanism, end plate and orifice ring were used in this test. The test results are compared with 36-element fuel pressure drop data which AECL performed by the SCTR facility

  18. Pharmacokinetic Study of a Diclofenac Sodium Capsule Filled with Enteric-coated Pellets in Healthy Chinese Volunteers by Liquid Chromatography-electrospray Ionization-tandem Mass Spectrometry.

    Science.gov (United States)

    Ma, J-Y; Liu, M; Yang, M; Zhao, H; Tong, Y; Zhang, Y; Deng, M; Liu, H

    2016-05-01

    The pharmacokinetic study of a diclofenac sodium capsule filled with enteric-coated pellets (abbreviated as CAPSULE) in healthy Chinese subjects was evaluated using liquid chromatography-electrospray ionization-tandem mass spectrometry with simple sample preparation. In a cross-over study, 12 healthy male volunteers were given 50 mg CAPSULE and diclofenac sodium enteric-coated tablet (abbreviated as TABLET, used as a control dosage form) at fasting. The Cmax, AUC0-t, and Tmax of CAPSULE were 1.01±0.52 μg/mL, 1.54±0.18 μg·h/mL, and 1.50±1.31 h, respectively. When compared with TABLET, the pharmacokinetic study showed that although this CAPSULE exhibited similar AUC (only 10% lower), it presented lower maximum plasma concentration, faster absorption and shorter time to reach maximum concentration. When compared with the previous study in Germany, obvious variations on Tmax were found in Chinese subjects taking CAPSULE, but not TABLET. The results indicated that individual difference should be paid attention when prescribing CAPSULE to Chinese patients. © Georg Thieme Verlag KG Stuttgart · New York.

  19. Galande, Dr Sanjeev

    Indian Academy of Sciences (India)

    Elected: 2010 Section: General Biology. Galande, Dr Sanjeev Ph.D. (IISc). Date of birth: 20 September 1967. Specialization: Epigenetics, Chromatin Biology, Gene Regulation, Genomics and Proteomics Address: Centre for Excellence in Epigenetics, Indian Institute of Science Education, & Research, Dr Homi Bhabha Road, ...

  20. Gaia DR2 documentation

    Science.gov (United States)

    van Leeuwen, F.; de Bruijne, J. H. J.; Arenou, F.; Bakker, J.; Blomme, R.; Busso, G.; Cacciari, C.; Castañeda, J.; Cellino, A.; Clotet, M.; Comoretto, G.; Eyer, L.; González-Núñez, J.; Guy, L.; Hambly, N.; Hobbs, D.; van Leeuwen, M.; Luri, X.; Manteiga, M.; Pourbaix, D.; Roegiers, T.; Salgado, J.; Sartoretti, P.; Tanga, P.; Ulla, A.; Utrilla Molina, E.; Abreu, A.; Altmann, M.; Andrae, R.; Antoja, T.; Audard, M.; Babusiaux, C.; Bailer-Jones, C. A. L.; Barache, C.; Bastian, U.; Beck, M.; Berthier, J.; Bianchi, L.; Biermann, M.; Bombrun, A.; Bossini, D.; Breddels, M.; Brown, A. G. A.; Busonero, D.; Butkevich, A.; Cantat-Gaudin, T.; Carrasco, J. M.; Cheek, N.; Clementini, G.; Creevey, O.; Crowley, C.; David, M.; Davidson, M.; De Angeli, F.; De Ridder, J.; Delbò, M.; Dell'Oro, A.; Diakité, S.; Distefano, E.; Drimmel, R.; Durán, J.; Evans, D. W.; Fabricius, C.; Fabrizio, M.; Fernández-Hernández, J.; Findeisen, K.; Fleitas, J.; Fouesneau, M.; Galluccio, L.; Gracia-Abril, G.; Guerra, R.; Gutiérrez-Sánchez, R.; Helmi, A.; Hernandez, J.; Holl, B.; Hutton, A.; Jean-Antoine-Piccolo, A.; Jevardat de Fombelle, G.; Joliet, E.; Jordi, C.; Juhász, Á.; Klioner, S.; Löffler, W.; Lammers, U.; Lanzafame, A.; Lebzelter, T.; Leclerc, N.; Lecoeur-Taïbi, I.; Lindegren, L.; Marinoni, S.; Marrese, P. M.; Mary, N.; Massari, D.; Messineo, R.; Michalik, D.; Mignard, F.; Molinaro, R.; Molnár, L.; Montegriffo, P.; Mora, A.; Mowlavi, N.; Muinonen, K.; Muraveva, T.; Nienartowicz, K.; Ordenovic, C.; Pancino, E.; Panem, C.; Pauwels, T.; Petit, J.; Plachy, E.; Portell, J.; Racero, E.; Regibo, S.; Reylé, C.; Rimoldini, L.; Ripepi, V.; Riva, A.; Robichon, N.; Robin, A.; Roelens, M.; Romero-Gómez, M.; Sarro, L.; Seabroke, G.; Segovia, J. C.; Siddiqui, H.; Smart, R.; Smith, K.; Sordo, R.; Soria, S.; Spoto, F.; Stephenson, C.; Turon, C.; Vallenari, A.; Veljanoski, J.; Voutsinas, S.

    2018-04-01

    The second Gaia data release, Gaia DR2, encompasses astrometry, photometry, radial velocities, astrophysical parameters (stellar effective temperature, extinction, reddening, radius, and luminosity), and variability information plus astrometry and photometry for a sample of pre-selected bodies in the solar system. The data collected during the first 22 months of the nominal, five-year mission have been processed by the Gaia Data Processing and Analysis Consortium (DPAC), resulting into this second data release. A summary of the release properties is provided in Gaia Collaboration et al. (2018b). The overall scientific validation of the data is described in Arenou et al. (2018). Background information on the mission and the spacecraft can be found in Gaia Collaboration et al. (2016), with a more detailed presentation of the Radial Velocity Spectrometer (RVS) in Cropper et al. (2018). In addition, Gaia DR2 is accompanied by various, dedicated papers that describe the processing and validation of the various data products. Four more Gaia Collaboration papers present a glimpse of the scientific richness of the data. In addition to this set of refereed publications, this documentation provides a detailed, complete overview of the processing and validation of the Gaia DR2 data. Gaia data, from both Gaia DR1 and Gaia DR2, can be retrieved from the Gaia archive, which is accessible from https://archives.esac.esa.int/gaia. The archive also provides various tutorials on data access and data queries plus an integrated data model (i.e., description of the various fields in the data tables). In addition, Luri et al. (2018) provide concrete advice on how to deal with Gaia astrometry, with recommendations on how best to estimate distances from parallaxes. The Gaia archive features an enhanced visualisation service which can be used for quick initial explorations of the entire Gaia DR2 data set. Pre-computed cross matches between Gaia DR2 and a selected set of large surveys are

  1. Capsule endoscopy—A mechatronics perspective

    Science.gov (United States)

    Lin, Lin; Rasouli, Mahdi; Kencana, Andy Prima; Tan, Su Lim; Wong, Kai Juan; Ho, Khek Yu; Phee, Soo Jay

    2011-03-01

    The recent advances in integrated circuit technology, wireless communication, and sensor technology have opened the door for development of miniature medical devices that can be used for enhanced monitoring and treatment of medical conditions. Wireless capsule endoscopy is one of such medical devices that has gained significant attention during the past few years. It is envisaged that future wireless capsule endoscopies replace traditional endoscopy procedures by providing advanced functionalities such as active locomotion, body fluid/tissue sampling, and drug delivery. Development of energy-efficient miniaturized actuation mechanisms is a key step toward achieving this goal. Here, we review some of the actuators that could be integrated into future wireless capsules and discuss the existing challenges.

  2. Isolation of Capsulate Bacteria from Acute Dentoalveolar Abscesses

    OpenAIRE

    Lewis, M. A. O.; Milligan, S. G.; MacFarlane, T. W.; Carmichael, F. A.

    2011-01-01

    The presence of a capsule was determined for 198 bacterial strains (57 facultative anaerobes, 141 strict anaerobes) isobdted from pus samples aspirated from 40 acute dentoalveolar abscesses. A total of 133 (67 per cent) of the isolates (42 facultative anaerobes, 91 strict anaerobes) were found to have a capsule. Possession ofa capsule may in part explain the apparent pathogenicity of the bacterial species encountered in acute dentoalveolar abscess.Keywords - Bacterial capsule; Acute dentoalve...

  3. Dr. Wernher von Braun and Dr. Ernst Stuhlinger Sign Citizenship Certificates

    Science.gov (United States)

    1955-01-01

    The members of the Peenemuende team and their family members were awarded the United States citizenship on April 14, 1955. Pictured here is Dr. Ernst Stuhlinger (middle) and Dr. Wernher von Braun signing U.S. citizenship certificates. Martin Schilling is at left.

  4. Capsule Endoscopy

    Science.gov (United States)

    ... because experience with it is limited and traditional upper endoscopy is widely available. Why it's done Your doctor might recommend a capsule endoscopy procedure to: Find the cause of gastrointestinal bleeding. If you have unexplained bleeding in your digestive ...

  5. Capsule development and utilization for material irradiation tests

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Young Hwan; Kim, B G; Joo, K N [and others

    2000-05-01

    The development program of advanced nuclear structural and fuel materials includes the in-pile tests using the instrumented capsule at HANARO. The tests were performed in the in-core test holes of CT, IR 1 and 2 and OR 4 and 5 of HANARO. Extensive efforts have also been made to establish design and manufacturing technology for the instrumented capsule and its related system, which should be compatible with the HANARO's characteristics. Since the first instrumented capsule(97M-01K) had been designed and successfully fabricated, five tests were done to support the users and provided the economic benefits to user by generating the essential in-pile information on the performance and structural integrity of materials. This paper describes the present status and future plans of these R and D activities for the development of the instrumented capsule including in-situ material property measurement capsules and nuclear fuel test capsules.

  6. Capsule development and utilization for material irradiation tests

    International Nuclear Information System (INIS)

    Kang, Young Hwan; Kim, B. G.; Joo, K. N.

    2000-05-01

    The development program of advanced nuclear structural and fuel materials includes the in-pile tests using the instrumented capsule at HANARO. The tests were performed in the in-core test holes of CT, IR 1 and 2 and OR 4 and 5 of HANARO. Extensive efforts have also been made to establish design and manufacturing technology for the instrumented capsule and its related system, which should be compatible with the HANARO's characteristics. Since the first instrumented capsule(97M-01K) had been designed and successfully fabricated, five tests were done to support the users and provided the economic benefits to user by generating the essential in-pile information on the performance and structural integrity of materials. This paper describes the present status and future plans of these R and D activities for the development of the instrumented capsule including in-situ material property measurement capsules and nuclear fuel test capsules

  7. Adsorption and desorption of phosphorus in ceramic capsules

    International Nuclear Information System (INIS)

    Almeida, J.R.F. de.

    1983-01-01

    Experiments were carried out in order to analyse the capacity of adsorving P from water using ceramic capsules with 32P, in the presence and absence of water flow through the capsule. Also studied was the desorption of 32 P from the capsule in water, with and without water flow. The desorption of residual 32 P was analysed by isotopic exchange with 31 P, also with and without water flow. It was observed that, in the presence of a flow, the capsule retained 32 P from the solution, which was weakly desorbed by water but was isotopically exchanged with 31 P. In the absence of a flow, the capsule was not an efficient P adsorber. (Author) [pt

  8. Production, deformation and mechanical investigation of magnetic alginate capsules

    Science.gov (United States)

    Zwar, Elena; Kemna, Andre; Richter, Lena; Degen, Patrick; Rehage, Heinz

    2018-02-01

    In this article we investigated the deformation of alginate capsules in magnetic fields. The sensitivity to magnetic forces was realised by encapsulating an oil in water emulsion, where the oil droplets contained dispersed magnetic nanoparticles. We solved calcium ions in the aqueous emulsion phase, which act as crosslinking compounds for forming thin layers of alginate membranes. This encapsulating technique allows the production of flexible capsules with an emulsion as the capsule core. It is important to mention that the magnetic nanoparticles were stable and dispersed throughout the complete process, which is an important difference to most magnetic alginate-based materials. In a series of experiments, we used spinning drop techniques, capsule squeezing experiments and interfacial shear rheology in order to determine the surface Young moduli, the surface Poisson ratios and the surface shear moduli of the magnetically sensitive alginate capsules. In additional experiments, we analysed the capsule deformation in magnetic fields. In spinning drop and capsule squeezing experiments, water droplets were pressed out of the capsules at elevated values of the mechanical load. This phenomenon might be used for the mechanically triggered release of water-soluble ingredients. After drying the emulsion-filled capsules, we produced capsules, which only contained a homogeneous oil phase with stable suspended magnetic nanoparticles (organic ferrofluid). In the dried state, the thin alginate membranes of these particles were rather rigid. These dehydrated capsules could be stored at ambient conditions for several months without changing their properties. After exposure to water, the alginate membranes rehydrated and became flexible and deformable again. During this swelling process, water diffused back in the capsule. This long-term stability and rehydration offers a great spectrum of different applications as sensors, soft actuators, artificial muscles or drug delivery systems.

  9. Capsule endoscopy: Beyond small bowel

    Directory of Open Access Journals (Sweden)

    Samuel N Adler

    2012-01-01

    Full Text Available In this article the brief and dramatic history of capsule endoscopy of the digestive tract is reviewed. Capsule endoscopy offers a non invasive method to diagnose diseases that affect the esophagus, small bowel and colon. Technological improvements relating to optics, software, data recorders with two way communication have revolutionized this field. These advancements have produced better diagnostic performance.

  10. Dr Math at your service

    CSIR Research Space (South Africa)

    Butgereit, L

    2012-10-01

    Full Text Available In this presentation the author explains how the Dr Math service works; how tutors are recruited to act as Dr Math; and how school pupils can reach Dr Math for help with their mathematics homework....

  11. HPLC method validation for modernization of the tetracycline hydrochloride capsule USP monograph

    Directory of Open Access Journals (Sweden)

    Emad M. Hussien

    2014-12-01

    Full Text Available This paper is a continuation to our previous work aiming at development and validation of a reversed-phase HPLC for modernization of tetracycline-related USP monographs and the USP general chapter . Previous results showed that the method is accurate and precise for the assay of tetracycline hydrochloride and the limit of 4-epianhydrotetracycline impurity in the drug substance and oral suspension monographs. The aim of the current paper is to examine the feasibility of the method for modernization of USP tetracycline hydrochloride capsule monograph. Specificity, linearity, accuracy and precision were examined for tetracycline hydrochloride assay and 4-epianhydrotetracycline limit. The method was linear in the concentration range from 80% to 160% (r>0.9998 of the assay concentration (0.1 mg/mL for tetracycline hydrochloride and from 50% to 150% (r>0.997 of the acceptance criteria specified in tetracycline hydrochloride capsule monograph for 4-epianhydrotetracycline (NMT 3.0%. The recovery at three concentration levels for tetracycline hydrochloride assay was between 99% and 101% and the RSD from six preparations at the concentration 0.1 mg/mL is less than 0.6%. The recovery for 4-epianhydrotetracycline limit procedure over the concentration range from 50% to 150% is between 96% and 102% with RSD less than 5%. The results met the specified acceptance criteria.

  12. Capsule development and utilization for material irradiation tests

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Young Hwan; Kim, B. G.; Joo, K. N. [and others

    2000-05-01

    The development program of advanced nuclear structural and fuel materials includes the in-pile tests using the instrumented capsule at HANARO. The tests were performed in the in-core test holes of CT, IR 1 and 2 and OR 4 and 5 of HANARO. Extensive efforts have also been made to establish design and manufacturing technology for the instrumented capsule and its related system, which should be compatible with the HANARO's characteristics. Since the first instrumented capsule(97M-01K) had been designed and successfully fabricated, five tests were done to support the users and provided the economic benefits to user by generating the essential in-pile information on the performance and structural integrity of materials. This paper describes the present status and future plans of these R and D activities for the development of the instrumented capsule including in-situ material property measurement capsules and nuclear fuel test capsules.

  13. Motion of an elastic capsule in a square microfluidic channel.

    Science.gov (United States)

    Kuriakose, S; Dimitrakopoulos, P

    2011-07-01

    In the present study we investigate computationally the steady-state motion of an elastic capsule along the centerline of a square microfluidic channel and compare it with that in a cylindrical tube. In particular, we consider a slightly over-inflated elastic capsule made of a strain-hardening membrane with comparable shearing and area-dilatation resistance. Under the conditions studied in this paper (i.e., small, moderate, and large capsules at low and moderate flow rates), the capsule motion in a square channel is similar to and thus governed by the same scaling laws with the capsule motion in a cylindrical tube, even though in the channel the cross section in the upstream portion of large capsules is nonaxisymmetric (i.e., square-like with rounded corners). When the hydrodynamic forces on the membrane increase, the capsule develops a pointed downstream edge and a flattened rear (possibly with a negative curvature) so that the restoring tension forces are increased as also happens with droplets. Membrane tensions increase significantly with the capsule size while the area near the downstream tip is the most probable to rupture when a capsule flows in a microchannel. Because the membrane tensions increase with the interfacial deformation, a suitable Landau-Levich-Derjaguin-Bretherton analysis reveals that the lubrication film thickness h for large capsules depends on both the capillary number Ca and the capsule size a; our computations determine the latter dependence to be (in dimensionless form) h ~ a(-2) for the large capsules studied in this work. For small and moderate capsule sizes a, the capsule velocity Ux and additional pressure drop ΔP+ are governed by the same scaling laws as for high-viscosity droplets. The velocity and additional pressure drop of large thick capsules also follow the dynamics of high-viscosity droplets, and are affected by the lubrication film thickness. The motion of our large thick capsules is characterized by a Ux-U ~ h ~ a(-2

  14. Equivalence of a single dose (1200 mg) compared to a three-time a day dose (400 mg) of chondroitin 4&6 sulfate in patients with knee osteoarthritis. Results of a randomized double blind placebo controlled study.

    Science.gov (United States)

    Zegels, B; Crozes, P; Uebelhart, D; Bruyère, O; Reginster, J Y

    2013-01-01

    Evaluation of the efficacy and safety of a single oral dose of a 1200 mg sachet of chondroitin 4&6 sulfate (CS 1200) vs three daily capsules of chondroitin 4&6 sulfate 400 mg (CS 3*400) (equivalence study) and vs placebo (superiority study) during 3 months, in patients with knee osteoarthritis (OA). Comparative, double-blind, randomized, multicenter study, including 353 patients of both genders over 45 years with knee OA. Minimum inclusion criteria were a Lequesne index (LI) ≥ 7 and pain ≥ 40 mm on a visual analogue scale (VAS). LI and VAS were assessed at baseline and after 1-3 months. Equivalence between CS was tested using the per-protocol procedure and superiority of CS vs placebo was tested using an intent-to-treat procedure. After 3 months of follow-up, no significant difference was demonstrated between the oral daily single dose of CS 1200 formulation and the three daily capsules of CS 400. Patients treated with CS 1200 or CS 3*400 were significantly improved compared to placebo after 3 months of follow-up in terms of LI (security and tolerability was observed between the three groups. This study suggests that a daily administration of an oral sachet of 1200 mg of chondroitin 4&6 sulfate allows a significant clinical improvement compared to a placebo, and a similar improvement when compared to a regimen of three daily capsules of 400 mg of the same active ingredient. Copyright © 2012 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  15. Drømmejobbet

    DEFF Research Database (Denmark)

    Harrebye, Silas

    2012-01-01

    Medarbejdere vil i fremtiden også kunne arbejde, mens de sover. Virksomheder tilbyder snart deres ansatte interne kurser i ‘lucid dreaming’. Disse giver mulighed for, at man i sine drømme bliver bevidst om, at man drømmer og således kan manipulere dem. Det skal nu udnyttes. Management...

  16. Development of remote welding techniques for in-pile IASCC capsules and evaluation of material integrity on capsules for long irradiation period

    Science.gov (United States)

    Shibata, A.; Nakano, J.; Ohmi, M.; Kawamata, K.; Nakagawa, T.; Tsukada, T.

    2012-03-01

    To simulate irradiation assisted stress corrosion cracking (IASCC) behavior by in-pile experiments, it is necessary to irradiate specimens up to a neutron fluence that is higher than the IASCC threshold fluence. Pre-irradiated specimens must be relocated from pre-irradiation capsules to in-pile capsules. Hence, a remote welding machine has been developed. And the integrity of capsule housing for a long term irradiation was evaluated by tensile tests in air and slow strain rate tests in water. Two type specimens were prepared. Specimens were obtained from the outer tubes of capsule irradiated to 1.0-3.9 × 1026 n/m2 (E > 1 MeV). And specimens were irradiated in a leaky capsule to 0.03-1.0 × 1026 n/m2. Elongation more than 15% in tensile test at 423 K was confirmed and no IGSCC fraction was shown in SSRT at 423 K which was estimated as temperature at the outer tubes of the capsule under irradiation.

  17. Development of remote welding techniques for in-pile IASCC capsules and evaluation of material integrity on capsules for long irradiation period

    International Nuclear Information System (INIS)

    Shibata, A.; Nakano, J.; Ohmi, M.; Kawamata, K.; Nakagawa, T.; Tsukada, T.

    2012-01-01

    To simulate irradiation assisted stress corrosion cracking (IASCC) behavior by in-pile experiments, it is necessary to irradiate specimens up to a neutron fluence that is higher than the IASCC threshold fluence. Pre-irradiated specimens must be relocated from pre-irradiation capsules to in-pile capsules. Hence, a remote welding machine has been developed. And the integrity of capsule housing for a long term irradiation was evaluated by tensile tests in air and slow strain rate tests in water. Two type specimens were prepared. Specimens were obtained from the outer tubes of capsule irradiated to 1.0–3.9 × 10 26 n/m 2 (E > 1 MeV). And specimens were irradiated in a leaky capsule to 0.03–1.0 × 10 26 n/m 2 . Elongation more than 15% in tensile test at 423 K was confirmed and no IGSCC fraction was shown in SSRT at 423 K which was estimated as temperature at the outer tubes of the capsule under irradiation.

  18. Polar tent for reduced perturbation of NIF ignition capsules

    Science.gov (United States)

    Hammel, B. A.; Pickworth, L.; Stadermann, M.; Field, J.; Robey, H.; Scott, H. A.; Smalyuk, V.

    2016-10-01

    In simulations, a tent that contacts the capsule near the poles and departs tangential to the capsule surface greatly reduces the capsule perturbation, and the resulting mass injected into the hot-spot, compared to current capsule support methods. Target fabrication appears feasible with a layered tent (43-nm polyimide + 8-nm C) for increased stiffness. We are planning quantitative measurements of the resulting shell- ρR perturbation near peak implosion velocity (PV) using enhanced self-emission backlighting, achieved by adding 1% Ar to the capsule fill in Symcaps (4He + H). Layered DT implosions are also planned for an integrated test of capsule performance. We will describe the design and simulation predictions. Prepared by LLNL under Contract DE-AC52-07NA27344.

  19. Diagnostic and therapeutic capsules and method of producing

    International Nuclear Information System (INIS)

    Morcos, N.A.; Haney, T.A.; Wedeking, P.W.

    1981-01-01

    An article of manufacture comprising a pharmaceutical radioactive capsule formed essentially of a non-toxic, water soluble material adapted to being ingested and rapidly disintegrating on contract with fluids of the gastro-intestinal tract, and having a filler material supporting a pharmaceutically useful radioactive compound absorbable from the gastro-intestinal tract said filler material being supported by said capsule. And a method of filling a pharmaceutical radioactive capsule comprising providing filler material supporting a pharmaceutically useful radioactive compound and transporting said filler material carrying a pharmaceutically useful radioactive compound into the chamber of said capsule

  20. Evidence for an intact polysaccharide capsule in Bordetella pertussis.

    Science.gov (United States)

    Neo, YiLin; Li, Rui; Howe, Josephine; Hoo, Regina; Pant, Aakanksha; Ho, SiYing; Alonso, Sylvie

    2010-03-01

    Polysaccharide capsules contribute to the pathogenesis of many bacteria species by providing resistance against various defense mechanisms. The production of a capsule in Bordetella pertussis, the etiologic agent of whooping cough, has remained controversial; earlier studies reported this pathogen as a capsulated microorganism whereas the recent B. pertussis genome analysis revealed the presence of a truncated capsule locus. In this work, using transmission electron microscopy and immunostaining approaches, we provide a formal evidence for the presence of an intact microcapsule produced at the surface of both laboratory strain and clinical isolates of B. pertussis. In agreement with previous studies, we found that the capsule is optimally produced in avirulent phase. Unexpectedly, the presence of the capsule was also detected at the surface of virulent B. pertussis bacteria. Consistently, a substantial transcriptional activity of the capsule operon was detected in virulent phase, suggesting that the capsular polysaccharide may play a role during pertussis pathogenesis. In vitro assays indicated that the presence of the capsule does not affect B. pertussis adherence to mammalian cells and does not further protect the bacterium from phagocytosis, complement-mediated killing or antimicrobial peptide attack. Copyright 2009. Published by Elsevier SAS.

  1. Endurance test for DUPIC capsule

    International Nuclear Information System (INIS)

    Chung, Heung June; Bae, K. K.; Lee, C. Y.; Park, J. M.; Ryu, J. S.

    1999-07-01

    This report presents the pressure drop, vibration and endurance test results for mini-plate fuel rig which were designed fabricately by KAERI. From the pressure drop test results, it is noted that the flow rate across the capsule corresponding to the pressure drop of 200 kPa is measured to be about 9.632 kg/sec. Vibration frequency for the capsule ranges from 14 to 18.5 Hz. RMS (Root Mean Square) displacement for the fuel rig is less than 14 μm, and the maximum displacement is less than 54 μm. Based on the endurance test results, the appreciable fretting wear for the DUPIC capsule was not detected. Oxidation on the support tube is observed, also tiny trace of wear between contact points observed. (author). 4 refs., 10 tabs., 45 figs

  2. Large Customers (DR Sellers)

    Energy Technology Data Exchange (ETDEWEB)

    Kiliccot, Sila [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2011-10-25

    State of the large customers for demand response integration of solar and wind into electric grid; openADR; CAISO; DR as a pseudo generation; commercial and industrial DR strategies; California regulations

  3. A simple method for preparing radioactive capsules in colon transit study

    International Nuclear Information System (INIS)

    Wang Shyhjen; Lin Wanyu; Tsai Shihchuan; Chen Granhun

    2000-01-01

    Colon transit study is currently performed by delivering technetium-99m or indium-111 labelled activated charcoal to the colon in a methacrylate-coated capsule (coated capsule). However, the coating procedure is complicated and methacrylate has not been approved by the Food and Drug Administration. Therefore, a simpler method is needed for the clinical routine use of colon transit study. In this study, we used a commercial empty enteric capsule and a coated capsule for the measurement of colon transit time. We compared the in vitro stability and in vivo scintigraphy of 99m Tc-labelled activated charcoal in the coated capsule and the enteric capsule to evaluate the possibility of clinical usage of the enteric capsule for colon transit time study. Activated charcoal powder was mixed with 99m Tc-diethylene triamine penta-acetic acid (DTPA) and vaporized to dryness. The dry 99m Tc-DTPA activated charcoal was loaded into the coated capsule and the enteric capsule. In vitro stability study was performed by immersing these capsules in a colourless buffer of variable pH which mimicked the conditions in the stomach and the small bowel. Capsule disruption was determined. Colon transit scintigraphy with 99m Tc-DTPA charcoal was performed in five normal volunteers using these two capsules. The in vitro stability of these two types of capsule was similar and the colon transit scintigraphy findings were almost identical. Most capsules dissolved in the ascending colon and very few in the terminal ileum. It is concluded that enteric capsule is a suitable alternative to coated capsule for measurement of colon transit. (orig.)

  4. Failure of the capsule for coated particles irradiation

    International Nuclear Information System (INIS)

    Yamaki, Jikei; Nomura, Yasushi; Nagamatsuya, Takaaki; Yamahara, Takeshi; Sakai, Haruyuki

    1975-10-01

    During operation cycle No. 27 of the JMTR (Japan Material Testing Reactor) on May 20, 1974, leakage of the fission product gas occurred from the capsule 72F-7A, which contained coated particles for the irradiation; the coated particles are for the development of a multi-purpose high temperature gas cooled reactor. The capsule was designed for heat 1600 0 C. Three nickel plates as the heat reflector were sandwiched in between the plates of titanium and zirconium, which were adsorbents for the impurity gases in the cladding tube (Nb-1%Zr). Temperatures of the plates were about 1000 0 C under the irradiation, so one metal diffused into the other metal through interfaces, resulting in the formation of an alloy. Its melting point was lower than those of metals in the capsule. The cladding material Nb-1%Zr was melted by the alloy and finally a pin hole developed through the cladding. The process of failure, design of the capsule, post-irradiation test of the capsule and the failure-reproducing experiment with a mock-up capsule are described. (auth.)

  5. Liquid-core nanocellulose-shell capsules with tunable oxygen permeability.

    Science.gov (United States)

    Svagan, A J; Bender Koch, C; Hedenqvist, M S; Nilsson, F; Glasser, G; Baluschev, S; Andersen, M L

    2016-01-20

    Encapsulation of oxygen sensitive components is important in several areas, including those in the food and pharmaceutical sectors, in order to improve shelf-life (oxidation resistance). Neat nanocellulose films demonstrate outstanding oxygen barrier properties, and thus nanocellulose-based capsules are interesting from the perspective of enhanced protection from oxygen. Herein, two types of nanocellulose-based capsules with liquid hexadecane cores were successfully prepared; a primary nanocellulose polyurea-urethane capsule (diameter: 1.66 μm) and a bigger aggregate capsule (diameter: 8.3 μm) containing several primary capsules in a nanocellulose matrix. To quantify oxygen permeation through the capsule walls, an oxygen-sensitive spin probe was dissolved within the liquid hexadecane core, allowing non-invasive measurements (spin-probe oximetry, electron spin resonance, ESR) of the oxygen concentration within the core. It was observed that the oxygen uptake rate was significantly reduced for both capsule types compared to a neat hexadecane solution containing the spin-probe, i.e. the slope of the non-steady state part of the ESR-curve was approximately one-third and one-ninth for the primary nanocellulose capsule and aggregated capsule, respectively, compared to that for the hexadecane sample. The transport of oxygen was modeled mathematically and by fitting to the experimental data, the oxygen diffusion coefficients of the capsule wall was determined. These values were, however, lower than expected and one plausible reason for this was that the ESR-technique underestimate the true oxygen uptake rate in the present systems at non-steady conditions, when the overall diffusion of oxygen was very slow. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. Deformation of ovalbumin-alginate capsules in a T-Junction

    Science.gov (United States)

    Häner, Edgar; Juel, Anne

    2015-11-01

    We study experimentally the flow-induced deformation of liquid-filled ovalbumin-alginate capsules in a T-junction. In applications, capsules/cells often negotiate branched networks with junctions thus experiencing large deformations. We investigate the constant volume-flux viscous flow of buoyancy-neutral thin-walled capsules close to the centreline of rectangular channels, by comparison to near-rigid gelled beads. The motion of the capsules in straight channels scales with the capillary number - the ration of viscous to elastic forces. However, the effect of elastic deformation on the motion is sufficiently weak that a rigid sphere model predicts the velocity of capsules with diameters of up to 70% of that of the channel to within 5%. In the T-junction, systematic selection of daughter channel (right-left) occurs outside a finite region around the channel centreline, by contrast with near-rigid gelled beads, where the actual centreline is the separator. We quantify the behaviour of capsules in terms of their longitudinal stretching (up to a factor of three without rupture). We show the large range of deformations encountered can be applied to the measurement of the elastic properties of capsules as well as to the geometric-induced sorting and manipulation of capsules.

  7. Development of a Low Temperature Irradiation Capsule for Research Reactor Materials

    International Nuclear Information System (INIS)

    Choo, Kee Nam; Cho, Man Soon; Lee, Cheol Yong; Yang, Sung Woo; Shin, Yoon Taek; Park, Seng Jae; Kang, Suk Hoon; Kang, Young Hwan; Park, Sang Jun

    2013-01-01

    A new capsule design was prepared and tested at HANARO for a neutron irradiation of core materials of research reactors as a part of the research reactor development project. Irradiation testing of the materials including graphite, beryllium, and zircaloy-4 that are supposed to be used as core materials in research reactors was required for irradiation at up to 8 reactor operation cycles at low temperature (<100 .deg. C). Therefore, three instrumented capsules were designed and fabricated for an evaluation of the neutron irradiation properties of the core materials (Graphite, Be, Zircaloy-4) of research reactors. The capsules were first designed and fabricated to irradiate materials at low temperature (<100 .deg. C) for a long cycle of 8 irradiation cycles at HANARO. Therefore, the safety of the new designed capsule should be fully checked before irradiation testing. Out-pile performance and endurance testing before HANARO irradiation testing was performed using a capsule under a 110% condition of a reactor coolant flow amount. The structural integrity of the capsule was analyzed in terms of a vibration-induced fatigue cracking of a rod tip of the capsule that is suspected to be the most vulnerable part of a capsule. Another two capsules were irradiated at HANARO for 4 cycles, and one capsule was transferred to a hot cell to examine the integrity of the rod tip of the capsule. After confirming the soundness of the 4 cycle-irradiated capsule, the remaining capsule was irradiated at up to 8 cycles at HANARO. Based on the structural integrity analysis of the capsule, an improved capsule design will be suggested for a longer irradiation test at HANARO

  8. Three-dimensional simulations of Nova capsule implosion experiments

    International Nuclear Information System (INIS)

    Marinak, M.M.; Tipton, R.E.; Landen, O.L.

    1995-01-01

    Capsule implosion experiments carried out on the Nova laser are simulated with the three-dimensional HYDRA radiation hydrodynamics code. Simulations of ordered near single mode perturbations indicate that structures which evolve into round spikes can penetrate farthest into the hot spot. Bubble-shaped perturbations can burn through the capsule shell fastest, however, causing even more damage. Simulations of a capsule with multimode perturbations shows spike amplitudes evolving in good agreement with a saturation model during the deceleration phase. The presence of sizable low mode asymmetry, caused either by drive asymmetry or perturbations in the capsule shell, can dramatically affect the manner in which spikes approach the center of the hot spot. Three-dimensional coupling between the low mode shell perturbations intrinsic to Nova capsules and the drive asymmetry brings the simulated yields into closer agreement with the experimental values

  9. Prava trećih država u gospodarskom pojasu obalne države

    Directory of Open Access Journals (Sweden)

    Marina Vokić Žužul

    2003-12-01

    Full Text Available Predmet ovoga rada je analiza prava koja u gospodarskom pojasu obalne države mogu ostvarivati sve obalne i neobalne države. uz detaljan prikaz pravnog uređenja materije u odredbama Konvencije o pravu mora iz 1982., razmatraju se i vladajuća gledišta međunarodnopravne doktrine te rješenja u zakonodavstvima pojedinih zemalja. Posebna pozornost je posvećena ostvarivanju tuh prava u potencijalnom hrvatskom gospodarskom pojasu, prvenstveno mogućim zahtjevima od strane susjednih neobalnih država i država u nepovoljnom geografskom položaju. Sva pitanja razmatrana u ovom radu upućuju na zaključak da ispunjavanje dužnosti prema drugim državama u budućem gospodarskom pojasu RH ne bi trebalo imati utjecaja na donošenje odluke o njegovom proglašenju.

  10. Equilibrium ignition for ICF capsules

    International Nuclear Information System (INIS)

    Lackner, K.S.; Colgate, S.A.; Johnson, N.L.; Kirkpatrick, R.C.; Menikoff, R.; Petschek, A.G.

    1993-01-01

    There are two fundamentally different approaches to igniting DT fuel in an ICF capsule which can be described as equilibrium and hot spot ignition. In both cases, a capsule which can be thought of as a pusher containing the DT fuel is imploded until the fuel reaches ignition conditions. In comparing high-gain ICF targets using cryogenic DT for a pusher with equilibrium ignition targets using high-Z pushers which contain the radiation. The authors point to the intrinsic advantages of the latter. Equilibrium or volume ignition sacrifices high gain for lower losses, lower ignition temperature, lower implosion velocity and lower sensitivity of the more robust capsule to small fluctuations and asymmetries in the drive system. The reduction in gain is about a factor of 2.5, which is small enough to make the more robust equilibrium ignition an attractive alternative

  11. Positron radiography of ignition-relevant ICF capsules

    Science.gov (United States)

    Williams, G. J.; Chen, Hui; Field, J. E.; Landen, O. L.; Strozzi, D. J.

    2017-12-01

    Laser-generated positrons are evaluated as a probe source to radiograph in-flight ignition-relevant inertial confinement fusion capsules. Current ultraintense laser facilities are capable of producing 2 × 1012 relativistic positrons in a narrow energy bandwidth and short time duration. Monte Carlo simulations suggest that the unique characteristics of such positrons allow for the reconstruction of both capsule shell radius and areal density between 0.002 and 2 g/cm2. The energy-downshifted positron spectrum and angular scattering of the source particles are sufficient to constrain the conditions of the capsule between preshot and stagnation. We evaluate the effects of magnetic fields near the capsule surface using analytic estimates where it is shown that this diagnostic can tolerate line integrated field strengths of 100 T mm.

  12. Capsule-odometer: a concept to improve accurate lesion localisation.

    Science.gov (United States)

    Karargyris, Alexandros; Koulaouzidis, Anastasios

    2013-09-21

    In order to improve lesion localisation in small-bowel capsule endoscopy, a modified capsule design has been proposed incorporating localisation and - in theory - stabilization capabilities. The proposed design consists of a capsule fitted with protruding wheels attached to a spring-mechanism. This would act as a miniature odometer, leading to more accurate lesion localization information in relation to the onset of the investigation (spring expansion e.g., pyloric opening). Furthermore, this capsule could allow stabilization of the recorded video as any erratic, non-forward movement through the gut is minimised. Three-dimensional (3-D) printing technology was used to build a capsule prototype. Thereafter, miniature wheels were also 3-D printed and mounted on a spring which was attached to conventional capsule endoscopes for the purpose of this proof-of-concept experiment. In vitro and ex vivo experiments with porcine small-bowel are presented herein. Further experiments have been scheduled.

  13. Production of 131I gelatin capsules

    International Nuclear Information System (INIS)

    Freud, A.; Hirshfeld, N.; Canfi, A.; Melamud, Y.

    1997-01-01

    Radioiodine ( 131 I) hard-gelatin capsules are widely used for the diagnosis and treatment of various thyroid disorders. Until 1980 radioiodine was supplied by us as a liquid dosage. This proved to be a rather inconvenient form since it resulted in inaccurate dosing by the physicians and caused frequent contamination of the patients and the hospital personnel. In an attempt to overcome these problems we have designed and constructed a production facility for capsules in which 1311 is packaged. Because of the extreme precautions necessary in handling radioactive compounds, encapsulation of radioactive materials requires specifically designed production techniques, special instrumentation and unique quality control procedures that are not encountered in the standard capsule production processes in the pharmaceutical industry

  14. Pneumatic capsule with a measuring system for in-pile irradiation

    International Nuclear Information System (INIS)

    Oshima, Keiichi; Yamazaki, Yasaburo; Hirata, Mitsuho; Ishii, Toshio; Shimozawa, Ryohei.

    1967-01-01

    A prior-art in-pile irradiation apparatus wherein a rabbit containing an irradiation specimen therein is inserted into and removed from a pile by a pneumatic system does not include means for measuring the temperature and pressure of the specimen under irradiation. When the rabbit is deformed during irradiation, it cannot be reliably recovered. A pneumatic capsule assembly with a measuring system according to this invention has a double structure which consists of an inner capsule containing the specimen therein and an outer capsule evacuated or filled with a gas. A thermocouple lace wire and a strain gauge are welded on the outside surface of the inner capsule as detection terminals for measuring the temperature and pressure. A rupture plate which bursts when the pressure in the inner capsule reaches a predetermined value is provided at a part of the inner capsule, and a fin for heat transmission is provided between the inner and outer capsules to thus prevent the deformation of the pneumatic capsule assembly as a whole. (Takasuka, S.)

  15. No stabilizing effect of the elbow joint capsule. A kinematic study

    DEFF Research Database (Denmark)

    Nielsen, K K; Olsen, Bo Sanderhoff

    1999-01-01

    We dissected 7 cadaveric elbow specimens, leaving the collateral ligaments and the joint capsule intact. The anterior and the posterior capsule were sequentially transected, followed by kinematic testings. We found no change in joint laxity after total transection of the capsule.......We dissected 7 cadaveric elbow specimens, leaving the collateral ligaments and the joint capsule intact. The anterior and the posterior capsule were sequentially transected, followed by kinematic testings. We found no change in joint laxity after total transection of the capsule....

  16. Efficacy of an ivermectin controlled-release capsule against nematode and arthropod endoparasites in sheep.

    Science.gov (United States)

    Rehbein, S; Batty, A F; Barth, D; Visser, M; Timms, B J; Barrick, R A; Eagleson, J S

    1998-03-28

    Five controlled trials were conducted in Germany or in the United Kingdom, using 74 female sheep of merino or Dorset horn breeds, to evaluate the efficacy of an ivermectin controlled-release capsule against naturally acquired or induced infections of gastrointestinal nematodes, lungworms and nasal bot larvae and against incoming infections with gastrointestinal and pulmonary nematodes. Half of the animals were treated with one ivermectin controlled-release capsule that delivered ivermectin at the rate of 1.6 mg per day for 100 days while the other half remained untreated. Parasites were counted 21, 28, 35 or 56 days after administration of the capsule. The treatment was highly effective (> or = 99 per cent) against established parasites of the following species: Haemonchus contortus (adults and fourth-stage larvae), Ostertagia circumcincta, O pinnata, O trifurcata, Ostertagia species fourth-stage larvae, Trichostrongylus axei, T colubriformis, T vitrinus, Cooperia curticei, Nematodirus battus, N filicollis, Strongyloides papillosus, Chabertia ovina, Oesophagostomum venulosum, Trichuris ovis, Tr skrjabini, Dictyocaulus filaria, Protostrongylus rufescens and Oestrus ovis (larvae). The treatment prevented the establishment of the gastrointestinal nematodes H contortus, O circumcincta, T axei, T colubriformis, C curticei, N battus, N filicollis, Ch ovina, Oe vennulosum and the establishment of the lungworm D filaria by > 99 per cent compared with untreated controls (P < or = 0.01).

  17. Radioactive gas-containing polymeric capsule

    International Nuclear Information System (INIS)

    Winchell, H.S.; Lewis, R.E.

    1975-01-01

    A disposable ventilation study system for dispensing a single patient dosage of gaseous radioisotopes to patients for pulmonary function studies is disclosed. A gas impermeable capsule encloses the gaseous radioisotope and is stored within a radioactivity shielding body of valve means which shears the capsule to dispense the radioisotope to the patient. A breathing bag receives the patient's exhalation of the radioisotope and permits rebreathing of the radioisotope by the patient. 18 claims, 7 drawing figures

  18. Design procedure of capsule with multistage heater control (named MUSTAC)

    International Nuclear Information System (INIS)

    Someya, Hiroyuki; Endoh, Yasuichi; Hoshiya, Taiji; Niimi, Motoji; Harayama, Yasuo

    1990-11-01

    A capsule with electric heaters at multistage (named MUSTAC) is a type of capsule used in JMTR. The heaters are assembled in the capsule. Supply electric current to the heaters can be independently adjusted with a control systems that keeps irradiation specimens to constant temperature. The capsule being used, the irradiation specimen are inserted into specimen holders. Gas-gap size, between outer surface of specimen holders and inner surface of capsule casing, is calculated and determined to be flatten temperature of loaded specimens over the region. The rise or drop of specimen temperature in accordance with reactor power fluctuations is corrected within the target temperature of specimen by using the heaters filled into groove at specimen holder surface. The present report attempts to propose a reasonable design procedure of the capsules by means of compiling experience for designs, works and irradiation data of the capsules and to prepare for useful informations against onward capsule design. The key point of the capsule lies on thermal design. Now design thermal calculations are complicated in case of specimen holder with multihole. Resolving these issues, it is considered from new on that an emphasis have to placed on settling a thermal calculation device, for an example, a computer program on calculation specimen temperature. (author)

  19. Noninvasive control of rhodamine-loaded capsules distribution in vivo

    Science.gov (United States)

    Stelmashchuk, O.; Tarakanchikova, Y.; Seryogina, E.; Piavchenko, G.; Zherebtsov, E.; Dunaev, A.; Popov, A.; Meglinski, I.

    2018-04-01

    Using fluorescence spectroscopy system with fibre-optical probe, we investigated the dynamics of propagation and circulation in the microcirculatory system of experimental nanocapsules fluorescent-labelled (rhodamine TRITC) nanocapsules. The studies were carried out in clinically healthy Wistar rats. The model animals were divided into control group and group received injections of the nanocapsules. The fluorescent measurements conducted transcutaneously on the thigh surface. The administration of the preparation with the rhodamine concentration of 5 mg/kg of animal weight resulted in twofold increase of fluorescence intensity by reference to the baseline level. As a result of the study, it was concluded that fluorescence spectroscopy can be used for transdermal measurements of the rhodamine-loaded capsules in vivo.

  20. Ingestible capsule for remote controlled release of a substance

    DEFF Research Database (Denmark)

    2014-01-01

    The application relates to an ingestible capsule (102) for delivery of a substance e.g. a pharmaceutical drug, to a human or animal. The ingestible capsule comprises a capsule wall structure (202) forming a substantially sealed reservoir or lumen holding the substance (204). An electrical resonance...

  1. THE PITTSBURGH SLOAN DIGITAL SKY SURVEY Mg II QUASAR ABSORPTION-LINE SURVEY CATALOG

    International Nuclear Information System (INIS)

    Quider, Anna M.; Nestor, Daniel B.; Turnshek, David A.; Rao, Sandhya M.; Weyant, Anja N.; Monier, Eric M.; Busche, Joseph R.

    2011-01-01

    We present a catalog of intervening Mg II quasar absorption-line systems in the redshift interval 0.36 ≤ z ≤ 2.28. The catalog was built from Sloan Digital Sky Survey Data Release Four (SDSS DR4) quasar spectra. Currently, the catalog contains ∼17, 000 measured Mg II doublets. We also present data on the ∼44, 600 quasar spectra which were searched to construct the catalog, including redshift and magnitude information, continuum-normalized spectra, and corresponding arrays of redshift-dependent minimum rest equivalent widths detectable at our confidence threshold. The catalog is available online. A careful second search of 500 random spectra indicated that, for every 100 spectra searched, approximately one significant Mg II system was accidentally rejected. Current plans to expand the catalog beyond DR4 quasars are discussed. Many Mg II absorbers are known to be associated with galaxies. Therefore, the combination of large size and well understood statistics makes this catalog ideal for precision studies of the low-ionization and neutral gas regions associated with galaxies at low to moderate redshift. An analysis of the statistics of Mg II absorbers using this catalog will be presented in a subsequent paper.

  2. Enrico Fermi Awards Ceremony for Dr. Mildred S. Dresselhaus and Dr. Burton Richter, May 2012 (Presentations, including remarks by Energy Secretary, Dr. Steven Chu)

    International Nuclear Information System (INIS)

    Chu, Steven

    2012-01-01

    The Fermi Award is a Presidential award and is one of the oldest and most prestigious science and technology honors bestowed by the U.S. Government. On May 7, 2012 it was conferred upon two exceptional scientists: Dr. Mildred Dresselhaus, 'for her scientific leadership, her major contributions to science and energy policy, her selfless work in science education and the advancement of diversity in the scientific workplace, and her highly original and impactful research,' and Dr. Burton Richter, 'for the breadth of his influence in the multiple disciplines of accelerator physics and particle physics, his profound scientific discoveries, his visionary leadership as SLAC Director, his leadership of science, and his notable contributions in energy and public policy.' Dr. John Holder, Director of the White House Office of Science and Technology Policy, opened the ceremony, and Dr. Bill Brinkman, Director of DOE's Office of Science introduced the main speaker, Dr. Steven Chu, U.S. Energy Secretary.

  3. Effect of calyx capsule-ethanol extract Hibiscus sabdariffa L. on renal function of healthy volunteers

    Science.gov (United States)

    Harun, N.; Darmawan, E.; Nurani, L. H.

    2017-11-01

    Hibiscus sabdariffa contains flavonoid, triterpenoid, anthocyanin which function as immunostimulant. H. sabdariffa is considered safe for animal renal; nonetheless, there are known side effects of which need to be further investigated for human renal. This research aims to investigate the effect of calyx capsule-ethanol extract H. sabdariffa for renal function of healthy male and female for 30 days period by monitoring Scr and Clcr component in their blood samples. The method of this experimental research was by pre and post-treatment by involving 20 healthy volunteers who have met inclusion and exclusion criteria. The volunteers have completed the informed consent for this experiment. Furthermore, volunteers were divided into two groups (10 male and 10 female). Each group was given orally 500 mg of calyx capsule-ethanol extract H. sabdariffa per day for 30 days period. Blood tests were taken on day 0, day 30 after consuming the capsule and day 45 (15 days after the last day of capsule intake) in order to measure the Scr and Clcr concentration in the blood samples by using Jaffe dan Cockcroft-Gault method. The results of each sampling day were further analyzed statistically and compared using Repeated ANOVA dan Friedman test. The results suggest that there was a difference in the renal function on day 0, 30 and 45 samplings. However, there was no significant difference in Scr dan Clcr concentrations on female and male volunteers (p>0.05). Specifically, the type of gender affects Scr concentration (p0.05). In addition, age and Body Mass Index (BMI) does not affect Scr and Clcr concentrations (p>0.05). The side effects discovered through the monitoring increased in mixturition and bloatedness. Calyx capsule-ethanol extract H. sabdariffa does not affect on renal function of healthy volunteers.

  4. Spheroidal and conical shapes of ferrofluid-filled capsules in magnetic fields

    Science.gov (United States)

    Wischnewski, Christian; Kierfeld, Jan

    2018-04-01

    We investigate the deformation of soft spherical elastic capsules filled with a ferrofluid in external uniform magnetic fields at fixed volume by a combination of numerical and analytical approaches. We develop a numerical iterative solution strategy based on nonlinear elastic shape equations to calculate the stretched capsule shape numerically and a coupled finite element and boundary element method to solve the corresponding magnetostatic problem and employ analytical linear response theory, approximative energy minimization, and slender-body theory. The observed deformation behavior is qualitatively similar to the deformation of ferrofluid droplets in uniform magnetic fields. Homogeneous magnetic fields elongate the capsule and a discontinuous shape transition from a spheroidal shape to a conical shape takes place at a critical field strength. We investigate how capsule elasticity modifies this hysteretic shape transition. We show that conical capsule shapes are possible but involve diverging stretch factors at the tips, which gives rise to rupture for real capsule materials. In a slender-body approximation we find that the critical susceptibility above which conical shapes occur for ferrofluid capsules is the same as for droplets. At small fields capsules remain spheroidal and we characterize the deformation of spheroidal capsules both analytically and numerically. Finally, we determine whether wrinkling of a spheroidal capsule occurs during elongation in a magnetic field and how it modifies the stretching behavior. We find the nontrivial dependence between the extent of the wrinkled region and capsule elongation. Our results can be helpful in quantitatively determining capsule or ferrofluid material properties from magnetic deformation experiments. All results also apply to elastic capsules filled with a dielectric liquid in an external uniform electric field.

  5. Treatment of rats with Jiangzhi Capsule improves liquid fructose-induced fatty liver: modulation of hepatic expression of SREBP-1c and DGAT-2.

    Science.gov (United States)

    Zhao, Yuanyang; Pan, Yongquan; Yang, Yifan; Batey, Robert; Wang, Jianwei; Li, Yuhao

    2015-06-02

    Jiangzhi Capsule is an Australian listed patented traditional Chinese medicine and has been used for management of lipid abnormalities over the past 10 years. To obtain a better understanding regarding Jiangzhi Capsule, the present study investigated the effects and underlying mechanisms of Jiangzhi Capsule on chronic fructose overconsumption-induced lipid abnormalities. Male rats were treated with liquid fructose in their drinking water over 14 weeks. Jiangzhi Capsule was co-administered (once daily, by oral gavage) during the last 7 weeks. Indexes of lipid and glucose homeostasis were determined enzymatically, by ELISA and/or histologically. Gene expression was analyzed by real-time PCR, Western blot and/or immunohistochemistry. Treatment with Jiangzhi Capsule (100 mg/kg) attenuated fructose-induced excessive triglyceride accumulation and Oil Red O-stained area in the liver. This effect was accompanied by amelioration of hyperinsulinemia. There was no significant difference in intakes of fructose and chow, and body weight between fructose control and fructose Jiangzhi Capsule-treated groups. Mechanistically, Jiangzhi Capsule downregulated fructose-stimulated hepatic overexpression of sterol regulatory element binding protein (SREBP)-1/1c at the mRNA and protein levels. Accordingly, the SREBP-1c downstream genes, acetyl-CoA carboxylase-1 and stearoyl-CoA desaturase-1, were also inhibited. In addition, acyl-coenzyme A:diacylglycerol acyltransferase (DGAT)-2 expression at the mRNA and protein levels in the liver was also inhibited after Jiangzhi Capsule treatment. In contrast, Jiangzhi Capsule affected neither carbohydrate response element binding protein, peroxisome proliferator-activated receptor (PPAR)-gamma and DGAT-1, nor PPAR-alpha and its target genes. These findings demonstrate the anti-steatotic action of Jiangzhi Capsule in fructose-fed rats, and modulation of hepatic SREBP-1c and DGAT-2 involved in hepatic de novo synthesis of fatty acids and triglyceride

  6. Effects of Wuling capsule on learning and memory disorder induced by post-stroke depression in rats

    Directory of Open Access Journals (Sweden)

    Zhong-chun LI

    2011-06-01

    Full Text Available Objective To evaluate the effects of Wuling capsule on learning and memory disorder induced by post-troke depression(PSD in rats,and examine the relationship between the changes in cognitive function and the expression of brain-derived neurotrophic factor(BDNF in hippocampus.Methods Forty male adult SD rats were randomly divided into four groups(10 each: untreated control group,model group,escitalopram treatment group and Wuling treatment group.All rats,except those in the untreated control group,underwent a paradigm of 3-week consecutive chronic unpredictable mild stress(CMS followed by selective right middle cerebral artery embolism to induce PSD.The sucrose preference was introduced to evaluate the level of depression and the spatial learning,and memory functions were detected using Morris water maze test.The expression of BDNF was analyzed by Western blotting.Results The cognitive function and hippocampal BDNF expression were significantly lower in model rats than in the untreated control group and the two treatment groups(P < 0.05.When escitalopram was administered once daily to the model rats at a dose of 0.2mg/(kg·d for 21 days along with the procedure of CMS,the depressed behavior was improved with BDNF protein expression rose from 0.41±0.07 to 0.86±0.09.Similar effects were found after treatment with Wuling capsule [100mg/(kg·d],except that the lower BDNF expression was not changed.Conclusion Wuling capsule can improve the learning and memory function in PSD rats,bat this effect is not related to the changes in BDNF expression in hippocampus.

  7. Scaling effects in spiral capsule robots.

    Science.gov (United States)

    Liang, Liang; Hu, Rong; Chen, Bai; Tang, Yong; Xu, Yan

    2017-04-01

    Spiral capsule robots can be applied to human gastrointestinal tracts and blood vessels. Because of significant variations in the sizes of the inner diameters of the intestines as well as blood vessels, this research has been unable to meet the requirements for medical applications. By applying the fluid dynamic equations, using the computational fluid dynamics method, to a robot axial length ranging from 10 -5 to 10 -2  m, the operational performance indicators (axial driving force, load torque, and maximum fluid pressure on the pipe wall) of the spiral capsule robot and the fluid turbulent intensity around the robot spiral surfaces was numerically calculated in a straight rigid pipe filled with fluid. The reasonableness and validity of the calculation method adopted in this study were verified by the consistency of the calculated values by the computational fluid dynamics method and the experimental values from a relevant literature. The results show that the greater the fluid turbulent intensity, the greater the impact of the fluid turbulence on the driving performance of the spiral capsule robot and the higher the energy consumption of the robot. For the same level of size of the robot, the axial driving force, the load torque, and the maximum fluid pressure on the pipe wall of the outer spiral robot were larger than those of the inner spiral robot. For different requirements of the operating environment, we can choose a certain kind of spiral capsule robot. This study provides a theoretical foundation for spiral capsule robots.

  8. Dynamics of an elastic capsule in moderate Reynolds number Poiseuille flow

    International Nuclear Information System (INIS)

    Shin, Soo Jai; Sung, Hyung Jin

    2012-01-01

    Highlights: ► Dynamics of a capsule in moderate Re Poiseuille flow were explored numerically. ► Capsule tends to tumbling motion for larger membrane elasticity and higher Re flow. ► Capsule undergoes swinging motion for larger size and aspect ratio of the capsule. ► Capsule tends to migrate to a specific lateral equilibrium as Re increases. ► Equilibrium position varies differently around the transition of the dynamic motion. - Abstract: The dynamic motions and lateral equilibrium positions of a two-dimensional elastic capsule in a Poiseuille flow were explored at moderate Reynolds number (10 ⩽ Re ⩽ 100) as a function of the initial lateral position (y 0 ), Re, aspect ratio (ε), size ratio (λ), membrane stretching coefficient (φ) and bending coefficient (γ). The transition between tank-treading (TT) and swinging (SW) to tumbling (TU) motions was observed and the lateral equilibrium positions of the capsules varied according to the conditions. The initial behavior of the elastic capsule was influenced by variation in the initial lateral position (y 0 ), but the equilibrium position and dynamic motion of the capsule were not affected by such variation. The capsules had a stronger tendency toward TU motion at higher values of Re, φ and γ, whereas the capsules underwent TT or SW motion as the values of ε and λ increased. Under moderate Re Poiseuille flows, capsules tended to migrate across streamlines to a specific equilibrium position. The lateral equilibrium position shifted toward the centerline at larger λ and migrated toward the wall at larger ε,φandγ. As Re increased, the equilibrium position first shifted toward the bottom wall, then toward the channel center. However, different equilibrium position trends were obtained around the SW–TU transition. The capsule undergoing TU motion tended to migrate downward toward the bottom wall more than the capsule undergoing SW motion, all other conditions being similar.

  9. Design of Endoscopic Capsule With Multiple Cameras.

    Science.gov (United States)

    Gu, Yingke; Xie, Xiang; Li, Guolin; Sun, Tianjia; Wang, Dan; Yin, Zheng; Zhang, Pengfei; Wang, Zhihua

    2015-08-01

    In order to reduce the miss rate of the wireless capsule endoscopy, in this paper, we propose a new system of the endoscopic capsule with multiple cameras. A master-slave architecture, including an efficient bus architecture and a four level clock management architecture, is applied for the Multiple Cameras Endoscopic Capsule (MCEC). For covering more area of the gastrointestinal tract wall with low power, multiple cameras with a smart image capture strategy, including movement sensitive control and camera selection, are used in the MCEC. To reduce the data transfer bandwidth and power consumption to prolong the MCEC's working life, a low complexity image compressor with PSNR 40.7 dB and compression rate 86% is implemented. A chipset is designed and implemented for the MCEC and a six cameras endoscopic capsule prototype is implemented by using the chipset. With the smart image capture strategy, the coverage rate of the MCEC prototype can achieve 98% and its power consumption is only about 7.1 mW.

  10. Capsule Shields the Function of Short Bacterial Adhesins

    OpenAIRE

    Schembri, Mark A.; Dalsgaard, Dorte; Klemm, Per

    2004-01-01

    Bacterial surface structures such as capsules and adhesins are generally regarded as important virulence factors. Here we demonstrate that capsules block the function of the self-recognizing protein antigen 43 through physical shielding. The phenomenon is not restricted to Escherichia coli but can occur in other gram-negative bacteria. Likewise, we show that other short adhesins exemplified by the AIDA-I protein are blocked by the presence of a capsule. The results support the notion that cap...

  11. Moisture diffusion and permeability characteristics of hydroxypropylmethylcellulose and hard gelatin capsules.

    Science.gov (United States)

    Barham, Ahmad S; Tewes, Frederic; Healy, Anne Marie

    2015-01-30

    The primary objective of this paper is to compare the sorption characteristics of hydroxypropylmethylcellulose (HPMC) and hard gelatin (HG) capsules and their ability to protect capsule contents. Moisture sorption and desorption isotherms for empty HPMC and HG capsules have been investigated using dynamic vapour sorption (DVS) at 25°C. All sorption studies were analysed using the Young-Nelson model equations which distinguishes three moisture sorption types: monolayer adsorption moisture, condensation and absorption. Water vapour diffusion coefficients (D), solubility (S) and permeability (P) parameters of the capsule shells were calculated. ANOVA was performed with the Tukey comparison test to analyse the effect of %RH and capsule type on S, P, and D parameters. The moisture uptake of HG capsules were higher than HPMC capsules at all %RH conditions studied. It was found that values of D and P across HPMC capsules were greater than for HG capsules at 0-40 %RH; whereas over the same %RH range S values were higher for HG than for HPMC capsules. S values decreased gradually as the %RH was increased up to 60% RH. To probe the effect of moisture ingress, spray dried lactose was loaded into capsules. Phase evolution was characterised by scanning electron microscopy (SEM), X-ray powder diffraction (XRD), and differential scanning calorimetry (DSC). The capsules under investigation are not capable of protecting spray dried lactose from induced solid state changes as a result of moisture uptake. For somewhat less moisture sensitive formulations, HPMC would appear to be a better choice than HG in terms of protection of moisture induced deterioration. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. Utilization of the capsule out-pile test facilities(2000-2003)

    Energy Technology Data Exchange (ETDEWEB)

    Cho, M. S.; Oh, J. M.; Cho, Y. G. and others

    2003-06-01

    Two out-pile test facilities were installed and being utilized for the non-irradiation tests outside the HANARO. The names of the facilities are the irradiation equipment design verification test facilities and the one-channel flow test device. In these facilities, the performance test of all capsules manufactured before loading in the HANARO and the design verification test for newly developed capsules were performed. The tests in these facilities include loading/unloading, pressure drop, endurance and vibration test etc. of capsules. In the period 2000{approx}2003, the performance tests for 8 material capsules of 99M-01K{approx}02M-05U were carried out, and the design verification tests of creep and fuel capsules developed newly were performed. For development of the creep capsule, pressure drop measurement, operation test of heater, T/C, LVDT and stress loading test were performed. In the design stage of the fuel capsule, the endurance and vibration test besides the above mentioned tests were carried out for verification of the safe operation during irradiation test in the HANARO. And in-chimeny bracket and the capsule supporting system were fixed and the flow tubes and the handling tools were manufactured for use at the facilities.

  13. Development of Multiple Capsule Robots in Pipe

    Directory of Open Access Journals (Sweden)

    Shuxiang Guo

    2018-05-01

    Full Text Available Swallowable capsule robots which travel in body cavities to implement drug delivery, minimally invasive surgery, and diagnosis have provided great potential for medical applications. However, the space constraints of the internal environment and the size limitations of the robots are great challenges to practical application. To address the fundamental challenges of narrow body cavities, a different-frequency driven approach for multiple capsule robots with screw structure manipulated by external electromagnetic field is proposed in this paper. The multiple capsule robots are composed of driven permanent magnets, joint permanent magnets, and a screw body. The screw body generates a propulsive force in a fluidic environment. Moreover, robots can form new constructions via mutual docking and release. To provide manipulation guidelines for active locomotion, a dynamic model of axial propulsion and circumferential torque is established. The multiple start and step-out frequencies for multiple robots are defined theoretically. Moreover, the different-frequency driven approach based on geometrical parameters of screw structure and the overlap angles of magnetic polarities is proposed to drive multiple robots in an identical electromagnetic field. Finally, two capsule robots were prototyped and experiments in a narrow pipe were conducted to verify the different motions such as docking, release, and cooperative locomotion. The experimental results demonstrated the validity of the driven approach for multiple capsule robots in narrow body cavities.

  14. In Memoriam: Dr. Frank John Fenner

    Centers for Disease Control (CDC) Podcasts

    This podcast reflects on one of the greatest pioneers in virology, Dr. Frank John Fenner. Dr. Frederick Murphy, a member of EID's editorial board and the Institute of Medicine, and professor of Pathology at the University of Texas Medical Branch in Galveston, shares professional and personal stories of Dr. Frank Fenner.

  15. Dynamic computed tomography of hepatocellular carcinoma with particular reference to capsule

    Energy Technology Data Exchange (ETDEWEB)

    Otsuji, Hideaki [Nara Prefectural Hospital (Japan); Uchida, Hideo; Ohishi, H

    1983-11-01

    Dynamic CT of 117 hepatocellular carcinoma was analyzed about the capsule. Capsules were detected in 57 cases (49%) and they were classified into three types. The tumor showed high density during 15 to 26 sec after bolus injection of conrast medium, but the capsule was not enhanced. Incidence of the capsule enhanced as ring high density was 73% during 37 to 90 sec and over 90% after 4 min. Dynamic CT was very useful in the elucidation of hemodynamics of capsules of hepatocellular carcinoma.

  16. Results from annual testing of ARECO cesium capsules from 1990-1994

    Energy Technology Data Exchange (ETDEWEB)

    Lundeen, J.E.

    1994-10-01

    The purpose of this report is to compile the results of the cesium capsule inspections and testing at the Applied Radiant Energy Corporation (ARECO) facility in Lynchburg, VA, performed in 1990, 1991, 1992, 1993, and 1994. The 25 cesium capsules at the ARECO facility were visually identified and clunk tested. A Go/No Go gauge test was required for capsules failing the clunk test. A visual inspection of capsules was required for the initial testing (1990). All 25 capsules passed the inspections and testing each year.

  17. High-gain capsule design for the HIDIF project

    International Nuclear Information System (INIS)

    Honrubia, J.J.; Cerrada, J.A.; Gomez, R.

    2000-01-01

    A high-gain capsule has been designed for the HIDIF project. The goal has been to relax the accelerator requirements by using a radiation pulse with lower peak temperature (220 eV) than previous designs (260 eV). The ablator material is beryllium doped with a very low concentration (0.2 atom %) of copper. The capsule absorbs 1.3 MJ and yields, approximately, 450 MJ in I-D simulations. The effect of the opacity of the ablator on capsule performance has been studied in detail. (authors)

  18. Capsule endoscopy in the diagnosis of Crohn’s disease

    Directory of Open Access Journals (Sweden)

    Niv Y

    2013-05-01

    Full Text Available Yaron NivDepartment of Gastroenterology, Rabin Medical Center, Tel Aviv University, Petah Tikva, IsraelAbstract: Crohn’s disease is a chronic inflammatory disorder affecting any part of the gastrointestinal tract, but frequently involves the small and large bowel. Typical presenting symptoms include abdominal pain and diarrhea. Patients with this disorder may also have extraintestinal manifestations, including arthritis, uveitis, and skin lesions. The PillCam™SB capsule is an ingestible disposable video camera that transmits high quality images of the small intestinal mucosa. This enables the small intestine to be readily accessible to physicians investigating for the presence of small bowel disorders, such as Crohn’s disease. Four meta-analyses have demonstrated that capsule endoscopy identifies Crohn’s disease when other methods are not helpful. It should be noted that it is the best noninvasive procedure for assessing mucosal status, but is not superior to ileocolonoscopy, which remains the gold standard for assessment of ileocolonic disease. Mucosal healing along the small bowel can only be demonstrated by an endoscopic procedure such as capsule endoscopy. Achievement of long-term mucosal healing has been associated with a trend towards a decreased need for hospitalization and a decreased requirement for corticosteroid treatment in patients with Crohn’s disease. Recently, we have developed and validated the Capsule Endoscopy Crohn’s Disease Activity Index (also known as the Niv score for Crohn’s disease of the small bowel. The next step is to expand our score to the colon, and to determine the role and benefit of a capsule endoscopy activity score in patients suffering from Crohn’s ileocolitis and/or colitis. This scoring system will also serve to improve our understanding of the impact of capsule endoscopy, and therefore treatment, on the immediate outcome of this disorder. As the best procedure available for assessing

  19. 95 GHz methanol masers near DR 21 and DR 21(OH)

    International Nuclear Information System (INIS)

    Plambeck, R.L.; Menten, K.M.

    1990-01-01

    The BIMA array is used to map the 95-GHz 8(0) to 7 1A(+) transition of methanol and the 98-GHz J = 2-1 transition of CS toward the DR 21(OH) and DR 21 star-forming regions. Several strong methanol masers were found. The positions of the two brightest masers were measured with an accuracy of about + or - 0.3 arcsec. Toward DR 21(OH), the positions, velocities, and line shapes of the 95 GHz masers are in excellent agreement with those of the 84-GHz 5(-1) to 4 () methanol masers previously mapped by Batrla and Menten (1988), demonstrating that maser emission in both transitions originates from the same clumps of gas. The methanol masers are offset from CS emission peaks and from other known infrared and maser sources; they may possibly be clustered along the interface between outflows, traced by shock-excited H2 emission, and dense ambient gas, traced by CS emission. 25 refs

  20. Capsule Development and Utilization for Material Irradiation Tests

    International Nuclear Information System (INIS)

    Kang, Young Hwan; Kim, B. G.; Joo, K. N.

    2003-05-01

    The objective of this project was to establish basic capsule irradiation technology using the multi-purpose research reactor [HANARO] to eventually support national R and D projects of advanced fuel and materials related to domestic nuclear power plants and next generation reactors. There are several national nuclear projects in KAERI, which require several irradiation tests to investigate in-pile behavior of nuclear reactor fuel and materials for the R and D of several types of fuels such as advanced PWR and DUPIC fuels and for the R and D of structural materials such as RPV(reactor pressure vessel) steel, Inconel, zirconium alloy, and stainless steel. At the moment, internal and external researchers in institutes, industries and universities are interested in investigating the irradiation characteristics of materials using the irradiation facilities of HANARO. For these kinds of material irradiation tests, it is important to develop various capsules using our own techniques. The development of capsules requires several leading-edge technologies and our own experiences related to design and fabrication. In the second phase from April 1,2000 to March 31, 2003, the utilization technologies were developed using various sensors for the measurements of temperature, pressure and displacement, and instrumented capsule technologies for the required fuel irradiation tests were developed. In addition, the improvement of the existing capsule technologies and the development of an in-situ measurable creep capsule for specific purposes were done to meet the various requirements of users

  1. Crosslinking studies in gelatin capsules treated with formaldehyde and in capsules exposed to elevated temperature and humidity.

    Science.gov (United States)

    Ofner, C M; Zhang, Y E; Jobeck, V C; Bowman, B J

    2001-01-01

    Incomplete in vitro capsule shell dissolution and subsequent drug release problems have recently received attention. A modified USP dissolution method was used to follow capsule shell dissolution, and a 2,4,6-trinitrobenzenesulfonic acid (TNBS) assay was used to follow loss of epsilon-amino groups to study this shell dissolution problem postulated to be due to gelatin crosslinking. The dissolution problems were simulated using hard gelatin capsule (HGC) shells previously treated with formaldehyde to crosslink the gelatin. These methods were also used to study the effect of uncrosslinked HGC stored under stressed conditions (37 degrees C and 81% RH) with or without the presence of soft gelatin capsule shells (SGC). A 120 ppm formaldehyde treatment reduced gelatin shell dissolution to 8% within 45 min in water at 37 degrees C. A 200 ppm treatment reduced gelatin epsilon-amino groups to 83% of the original uncrosslinked value. The results also support earlier reports of non-amino group crosslinking by formaldehyde in gelatin. Under stressed conditions, HGC stored alone showed little change over 21 weeks. However, by 12 to 14 weeks, the HGC exposed to SGC showed a 23% decrease in shell dissolution and an 8% decrease in the number of epsilon-amino groups. These effects on the stressed HGC are ascribed to a volatile agent from SGC shells, most likely formaldehyde, that crosslinked nearby HGC shells. This report also includes a summary of the literature on agents that reduce gelatin and capsule shell dissolution and the possible mechanisms of this not-so-simple problem. Copyright 2001 Wiley-Liss, Inc. and the American Pharmaceutical Association J Pharm Sci 90: 79-88, 2001

  2. Dr Stanislaw Huskowski, Mayor of Wroclaw, Poland

    CERN Multimedia

    Patrice Loïez

    2002-01-01

    Dr Stanislaw Huskowski, Mayor of Wroclaw, Poland visiting the ATLAS magnet assembly hall, building 180 with Mr Carlo Lamprecht, State Councillor, Dr Stanislaw Huskowski and Dr Peter Jenni, ATLAS Spokesperson

  3. Capsule-Fixated Intraocular Lens Implantation in Small Pupil Cases.

    Science.gov (United States)

    Schojai, Merita; Schultz, Tim; Burkhard Dick, H

    2017-08-01

    To describe a new technique for implantation of capsule-fixated intraocular lenses (IOLs) (FEMTIS; Oculentis, Berlin, Germany) in patients with small pupils. In 4 eyes with small pupils, an anterior capsule-fixated IOL was implanted into the capsular bag after femtosecond laser treatment. The two large and two small flaps of the IOL were elevated to the front of the iris and the anterior capsule. Finally, the iris was flipped over the flaps to ensure a fixation of the capsule inside of the capsulotomy. In all cases, the implantation of anterior capsule-fixated IOLs was possible. No complications occurred during surgery or within the first months after surgery. With the described technique, capsulefixated IOLs can be implanted in eyes with small pupil easily and safely. This type of IOL has great potential to improve the refractive outcome by better prediction of the postoperative IOL position and eliminating IOL rotation after cataract surgery. [J Refract Surg. 2017;33(8):568-570.]. Copyright 2017, SLACK Incorporated.

  4. Triggered Release from Polymer Capsules

    Energy Technology Data Exchange (ETDEWEB)

    Esser-Kahn, Aaron P. [Univ. of Illinois, Urbana, IL (United States). Beckman Inst. for Advanced Science and Technology and Dept. of Chemistry; Odom, Susan A. [Univ. of Illinois, Urbana, IL (United States). Beckman Inst. for Advanced Science and Technology and Dept. of Chemistry; Sottos, Nancy R. [Univ. of Illinois, Urbana, IL (United States). Beckman Inst. for Advanced Science and Technology and Dept. of Materials Science and Engineering; White, Scott R. [Univ. of Illinois, Urbana, IL (United States). Beckman Inst. for Advanced Science and Technology and Dept. of Aerospace Engineering; Moore, Jeffrey S. [Univ. of Illinois, Urbana, IL (United States). Beckman Inst. for Advanced Science and Technology and Dept. of Chemistry

    2011-07-06

    Stimuli-responsive capsules are of interest in drug delivery, fragrance release, food preservation, and self-healing materials. Many methods are used to trigger the release of encapsulated contents. Here we highlight mechanisms for the controlled release of encapsulated cargo that utilize chemical reactions occurring in solid polymeric shell walls. Triggering mechanisms responsible for covalent bond cleavage that result in the release of capsule contents include chemical, biological, light, thermal, magnetic, and electrical stimuli. We present methods for encapsulation and release, triggering methods, and mechanisms and conclude with our opinions on interesting obstacles for chemically induced activation with relevance for controlled release.

  5. What we have learned and what to expect from capsule endoscopy.

    Science.gov (United States)

    Adler, Samuel N; Bjarnason, Ingvar

    2012-10-16

    Capsule endoscopy was conceived by Gabriel Iddan and Paul Swain independently two decades ago. These applications include but are not limited to Crohn's disease of the small bowel, occult gastrointestinal bleeding, non steroidal anti inflammatory drug induced small bowel disease, carcinoid tumors of the small bowel, gastro intestinal stromal tumors of the small bowel and other disease affecting the small bowel. Capsule endoscopy has been compared to traditional small bowel series, computerized tomography studies and push enteroscopy. The diagnostic yield of capsule endoscopy has consistently been superior in the diagnosis of small bowel disease compared to the competing methods (small bowel series, computerized tomography, push enteroscopy) of diagnosis. For this reason capsule endoscopy has enjoyed a meteoric success. Image quality has been improved with increased number of pixels, automatic light exposure adaptation and wider angle of view. Further applications of capsule endoscopy of other areas of the digestive tract are being explored. The increased transmission rate of images per second has made capsule endoscopy of the esophagus a realistic possibility. Technological advances that include a double imager capsule with a nearly panoramic view of the colon and a variable frame rate adjusted to the movement of the capsule in the colon have made capsule endoscopy of the colon feasible. The diagnostic rate for the identification of patients with polyps equal to or larger than 6 mm is high. Future advances in technology and biotechnology will lead to further progress. Capsule endoscopy is following the successful modern trend in medicine that replaces invasive tests with less invasive methodology.

  6. Dr Stanislaw Huskowski, Mayor of Wroclaw, Poland

    CERN Multimedia

    Patrice Loïez

    2002-01-01

    Dr Stanislaw Huskowski, Mayor of Wroclaw, Poland visiting the ATLAS magnet assembly hall, building 180. From l to r: Mr Carlo Lamprecht, State Councillor, Dr Stanislaw Huskowski and Dr Peter Jenni, ATLAS Spokesperson

  7. Safety evaluation for packaging (onsite) singly encapsulated cesium chloride capsules

    International Nuclear Information System (INIS)

    Smyth, W.W.

    1997-01-01

    Three nonstandard Waste Encapsulation and Storage Facility (WESF) cesium chloride capsules are being shipped from WESF (225B building) to the 324 building. They would normally be shipped in the Beneficial Uses Shipping System (BUSS) cask under its US Department of Energy (DOE) license (DOE 1996), but these capsules are nonstandard: one has a damaged or defective weld in the outer layer of encapsulation, and two have the outer encapsulation removed. The 3 capsules, along with 13 other capsules, will be overpacked in the 324 building to meet the requirements for storage in WESF's pool

  8. Capsule shields the function of short bacterial adhesins

    DEFF Research Database (Denmark)

    Schembri, Mark; Dalsgaard, D.; Klemm, Per

    2004-01-01

    Bacterial surface structures such as capsules and adhesins are generally regarded as important virulence factors. Here we demonstrate that capsules block the function of the self-recognizing protein antigen 43 through physical shielding. The phenomenon is not restricted to Escherichia coli but can...

  9. Toward an integrated model of capsule regulation in Cryptococcus neoformans.

    Directory of Open Access Journals (Sweden)

    Brian C Haynes

    2011-12-01

    Full Text Available Cryptococcus neoformans is an opportunistic fungal pathogen that causes serious human disease in immunocompromised populations. Its polysaccharide capsule is a key virulence factor which is regulated in response to growth conditions, becoming enlarged in the context of infection. We used microarray analysis of cells stimulated to form capsule over a range of growth conditions to identify a transcriptional signature associated with capsule enlargement. The signature contains 880 genes, is enriched for genes encoding known capsule regulators, and includes many uncharacterized sequences. One uncharacterized sequence encodes a novel regulator of capsule and of fungal virulence. This factor is a homolog of the yeast protein Ada2, a member of the Spt-Ada-Gcn5 Acetyltransferase (SAGA complex that regulates transcription of stress response genes via histone acetylation. Consistent with this homology, the C. neoformans null mutant exhibits reduced histone H3 lysine 9 acetylation. It is also defective in response to a variety of stress conditions, demonstrating phenotypes that overlap with, but are not identical to, those of other fungi with altered SAGA complexes. The mutant also exhibits significant defects in sexual development and virulence. To establish the role of Ada2 in the broader network of capsule regulation we performed RNA-Seq on strains lacking either Ada2 or one of two other capsule regulators: Cir1 and Nrg1. Analysis of the results suggested that Ada2 functions downstream of both Cir1 and Nrg1 via components of the high osmolarity glycerol (HOG pathway. To identify direct targets of Ada2, we performed ChIP-Seq analysis of histone acetylation in the Ada2 null mutant. These studies supported the role of Ada2 in the direct regulation of capsule and mating responses and suggested that it may also play a direct role in regulating capsule-independent antiphagocytic virulence factors. These results validate our experimental approach to dissecting

  10. Non-destructive tests of capsules for JMTR irradiation examination

    International Nuclear Information System (INIS)

    Tanaka, Hidetaka; Nagao, Yoshiharu; Sato, Masashi; Osawa, Kenji

    2007-03-01

    Irradiation examination are increasing in advanced irradiation research for accurate prediction control and evaluation of irradiation parameter such as neutron fluence, etc. by using JMTR. Irradiation capsule internals are therefore structurally complicated recently. This report described the procedure of non destructive tests such as radiographic test, penetrant test, ultrasonic test, etc. for inspection of irradiation capsules in JMTR, and the result of Test-case of confirmation procedure for internal parts of irradiation capsules. (author)

  11. Regional Variation Is Present in Elbow Capsules after Injury

    OpenAIRE

    Germscheid, Niccole M.; Hildebrand, Kevin A.

    2006-01-01

    Myofibroblast numbers and α-smooth muscle actin expression are increased in anterior joint capsules of patients with posttraumatic elbow contractures. The purpose of our study was to determine whether these changes occur regionally or throughout the entire joint capsule. We hypothesized that the α-smooth muscle actin mRNA expression and the myofibroblast numbers in posterior joint capsules would be elevated in elbows obtained from patients with posttraumatic joint contractures compared with j...

  12. SATCAP-C : a program for thermal hydraulic design of pressurized water injection type capsule

    International Nuclear Information System (INIS)

    Harayama, Yasuo; Someya, Hiroyuki; Asoh, Tomokazu; Niimi, Motoji

    1992-10-01

    There are capsules called 'Pressure Water Injection Type Capsule' as a kind of irradiation devices at the Japan Materials Testing Reactor (JMTR). A type of the capsules is a 'Boiling Water Capsule' (usually named BOCA). The other type is a 'Saturated Temperature Capsule' (named SATCAP). When the water is kept at a constant pressure, the water temperature does not become higher than the saturated temperature so far as the water does not fully change to steam. These type capsules are designed on the basis of the conception of applying the water characteristic to the control of irradiation temperature of specimens in the capsules. In designing of the capsules in which the pressurized water is injected, thermal performances have to be understood as exactly as possible. It is not easy however to predict thermal performances such as axially temperature distribution of water injected in the capsule, because there are heat-sinks at both side of inner and outer of capsule casing as the result that the water is fluid. Then, a program (named SATCAP-C) for the BOCA and SATCAP was compiled to grasp the thermal performances in the capsules and has been used the design of the capsules and analysis of the data obtained from some actual irradiation capsules. It was confirmed that the program was effective in thermal analysis for the capsules. The analysis found out the values for heat transfer coefficients at various surfaces of capsule components and some thermal characteristics of capsules. (author)

  13. Relative bioavailability of single doses of prolonged-release tacrolimus administered as a suspension, orally or via a nasogastric tube, compared with intact capsules: a phase 1 study in healthy participants.

    Science.gov (United States)

    Undre, Nasrullah; Dickinson, James

    2017-04-04

    Tacrolimus, an immunosuppressant widely used in solid organ transplantation, is available as a prolonged-release capsule for once-daily oral administration. In the immediate postsurgical period, if patients cannot take intact capsules orally, tacrolimus therapy is often initiated as a suspension of the capsule contents, delivered orally or via a nasogastric tube. This study evaluated the relative bioavailability of prolonged-release tacrolimus suspension versus intact capsules in healthy participants. A phase 1, open-label, single-dose, cross-over study. A single clinical research unit. In total, 20 male participants, 18-55 years old, entered and completed the study. All participants received nasogastric administration of tacrolimus 10 mg suspension in treatment period 1, with randomisation to oral administration of suspension or intact capsules in periods 2 and 3. Blood concentration-time profile over 144 hours was used to estimate pharmacokinetic parameters. Primary end point: relative bioavailability of prolonged-release intact capsule versus oral or nasogastric administration of prolonged-release tacrolimus suspension (area under the concentration-time curve (AUC) from time 0 to infinity post-tacrolimus dose (AUC 0-∞ ); AUC measured until the last quantifiable concentration (AUC 0-tz ); maximum observed concentration (C max ); time to C max (T max )). Tolerability was assessed throughout the study. Relative bioavailability of prolonged-release tacrolimus suspension administered orally was similar to intact capsules, with a ratio of least-square means for AUC 0-tz and AUC 0-∞ of 1.05 (90% CI 0.96 to 1.14). Bioavailability was lower with suspension administered via a nasogastric tube versus intact capsules (17%; ratio 0.83; CI 0.76 to 0.92). C max was higher for oral and nasogastric suspension (30% and 28%, respectively), and median T max was shorter (difference 1.0 and 1.5 hours postdose, respectively) versus intact capsules (2.0 hours). Single 10 mg

  14. Simulations of indirectly driven gas-filled capsules at the National Ignition Facility

    Energy Technology Data Exchange (ETDEWEB)

    Weber, S. V.; Casey, D. T.; Eder, D. C.; Pino, J. E.; Smalyuk, V. A.; Remington, B. A.; Rowley, D. P.; Yeamans, C. B.; Tipton, R. E.; Barrios, M.; Benedetti, R.; Berzak Hopkins, L.; Bleuel, D. L.; Bond, E. J.; Bradley, D. K.; Caggiano, J. A.; Callahan, D. A.; Cerjan, C. J.; Clark, D. S.; Divol, L. [Lawrence Livermore National Laboratory, Livermore, California 94550 (United States); and others

    2014-11-15

    Gas-filled capsules imploded with indirect drive on the National Ignition Facility have been employed as symmetry surrogates for cryogenic-layered ignition capsules and to explore interfacial mix. Plastic capsules containing deuterated layers and filled with tritium gas provide a direct measure of mix of ablator into the gas fuel. Other plastic capsules have employed DT or D{sup 3}He gas fill. We present the results of two-dimensional simulations of gas-filled capsule implosions with known degradation sources represented as in modeling of inertial confinement fusion ignition designs; these are time-dependent drive asymmetry, the capsule support tent, roughness at material interfaces, and prescribed gas-ablator interface mix. Unlike the case of cryogenic-layered implosions, many observables of gas-filled implosions are in reasonable agreement with predictions of these simulations. Yields of TT and DT neutrons as well as other x-ray and nuclear diagnostics are matched for CD-layered implosions. Yields of DT-filled capsules are over-predicted by factors of 1.4–2, while D{sup 3}He capsule yields are matched, as well as other metrics for both capsule types.

  15. Dr Pugh: a poisoner?

    Science.gov (United States)

    Paull, J D; Morris, G M

    2012-07-01

    On 16 February 1845 the Reverend W. H. Browne, rector of St John's Church in Launceston, Van Diemen's Land, wrote in his journal, "My dear Wife died very suddenly almost immediately after and in consequence of taking a preparation of Hyd. Cyan. Acid prepared & supplied by Dr Pugh". This journal entry raises a number of questions. Was Dr Pugh treating a condition which he thought merited that treatment or was it a ghastly mistake? Was Caroline Browne suffering from pulmonary tuberculosis? Was hydrocyanic acid an accepted treatment at that time? Did Mrs Browne take the wrong dose? Was an incorrect concentration of the drug prepared by Dr Pugh? Did he use the wrong pharmacopoeia in preparing the hydrocyanic acid? Why was there no inquest? Only some of these questions can be answered.

  16. The first capsule implosion experiments on Orion

    International Nuclear Information System (INIS)

    Garbett, W J; Horsfield, C J; Gales, S G; Leatherland, A E; Rubery, M S; Coltman, J E; Meadowcroft, A E; Rice, S J; Simons, A J; Woolhead, V E

    2016-01-01

    Direct drive capsule implosions are being developed on the Orion laser at AWE as a platform for ICF and HED physics experiments. The Orion facility combines both long pulse and short-pulse beams, making it well suited for studying the physics of alternative ignition approaches. Orion implosions also provide the opportunity to study aspects of polar direct drive. Limitations on drive symmetry from the relatively small number of laser beams makes predictive modelling of the implosions challenging, resulting in some uncertainty in the expected capsule performance. Initial experiments have been fielded to evaluate baseline capsule performance and inform future design optimization. Highly promising DD fusion neutron yields in excess of 10 9 have been recorded. Results from the experiments are presented alongside radiation-hydrocode modelling. (paper)

  17. [Exploring the clinical characters of Shugan Jieyu capsule through text mining].

    Science.gov (United States)

    Pu, Zheng-Ping; Xia, Jiang-Ming; Xie, Wei; He, Jin-Cai

    2017-09-01

    The study was main to explore the clinical characters of Shugan Jieyu capsule through text mining. The data sets of Shugan Jieyu capsule were downloaded from CMCC database by the method of literature retrieved from May 2009 to Jan 2016. Rules of Chinese medical patterns, diseases, symptoms and combination treatment were mined out by data slicing algorithm, and they were demonstrated in frequency tables and two dimension based network. Then totally 190 literature were recruited. The outcomess suggested that SC was most frequently correlated with liver Qi stagnation. Primary depression, depression due to brain disease, concomitant depression followed by physical diseases, concomitant depression followed by schizophrenia and functional dyspepsia were main diseases treated by Shugan Jieyu capsule. Symptoms like low mood, psychic anxiety, somatic anxiety and dysfunction of automatic nerve were mainy relieved bv Shugan Jieyu capsule.For combination treatment. Shugan Jieyu capsule was most commonly used with paroxetine, sertraline and fluoxetine. The research suggested that syndrome types and mining results of Shugan Jieyu capsule were almost the same as its instructions. Syndrome of malnutrition of heart spirit was the potential Chinese medical pattern of Shugan Jieyu capsule. Primary comorbid anxiety and depression, concomitant comorbid anxiety and depression followed by physical diseases, and postpartum depression were potential diseases treated by Shugan Jieyu capsule.For combination treatment, Shugan Jieyu capsule was most commonly used with paroxetine, sertraline and fluoxetine. Copyright© by the Chinese Pharmaceutical Association.

  18. The double capsules in macro-textured breast implants.

    Science.gov (United States)

    Giot, Jean-Philippe; Paek, Laurence S; Nizard, Nathanael; El-Diwany, Mostafa; Gaboury, Louis A; Nelea, Monica; Bou-Merhi, Joseph S; Harris, Patrick G; Danino, Michel A

    2015-10-01

    Breast implants are amongst the most widely used types of permanent implants in modern medicine and have both aesthetic and reconstructive applications with excellent biocompatibility. The double capsule is a complication associated with textured prostheses that leads to implant displacement; however, its etiology has yet to be elucidated. In this study, 10 double capsules were sampled from breast expander implants for in-depth analysis; histologically, the inner capsular layer demonstrated highly organized collagen in sheets with delamination of fibers. At the prosthesis interface (PI) where the implant shell contacts the inner capsular layer, scanning electron microscopy (SEM) revealed a thin layer which mirrored the three-dimensional characteristics of the implant texture; the external surface of the inner capsular layer facing the intercapsular space (ICS) was flat. SEM examination of the inner capsule layer revealed both a large bacterial presence as well as biofilm deposition at the PI; a significantly lower quantity of bacteria and biofilm were found at the ICS interface. These findings suggest that the double capsule phenomenon's etiopathogenesis is of mechanical origin. Delamination of the periprosthetic capsule leads to the creation of the ICS; the maintained separation of the 2 layers subsequently alters the biostability of the macro-textured breast implant. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. [Therapeutic efficacy of compound Xuanju capsule on autoimmune prostatitis in rats: an experimental study].

    Science.gov (United States)

    Li, Tian-Fu; Wu, Qiu-Yue; Li, Wei-Wei; Zhang, Cui; Li, Na; Shang, Xue-Jun; Xia, Xin-Yi; Xu, Hao-Qin; Huang, Yu-Feng

    2014-05-01

    To evaluate the therapeutic effect of Compound Xuanju Capsule (CXC) on autoimmune prostatitis in rat models. Sixty healthy male Wistar rats were randomly divided into five groups of equal number: blank control, low-concentration purified prostate protein (low-conc PPP), low-conc PPP + CXC treatment, high-concentration PPP (hi-con PPP), and hi-conc PPP + CXC treatment. Autoimmune prostatitis models were established by intragastric administration of PPP solution at 15 mg/ml (low concentration) and 80 mg/ml, respectively. At 30 days after modeling, the rats in the blank control and low-conc and hi-conc PPP model groups were treated with normal saline, and those in the other two groups with CXC at a daily dose of 0.068 g/ml. At 30, 45, and 60 days, all the animals were sacrificed for observation of pathological changes in the prostate tissue and determination of the levels of IL-8, IL-10, and TNF-alpha in the serum. Compared with the PPP models, the hi-conc PPP + CXC group showed significantly reduced levels of IL-8 and TNF-alpha in the serum at 45 days ([148.54 +/- 17.23] and [62.14 +/- 5.59] pg/ml vs [100.77 +/- 11.08] and [32.63 +/- 2.91] pg/ml, P microscope. Compound Xuanju Capsule is efficacious on autoimmune prostatis in rats by reducing inflammatory changes in the prostate tissue and improving the expression of inflammatory factors.

  20. Versatile Loading of Diverse Cargo into Functional Polymer Capsules.

    Science.gov (United States)

    Richardson, Joseph J; Maina, James W; Ejima, Hirotaka; Hu, Ming; Guo, Junling; Choy, Mei Y; Gunawan, Sylvia T; Lybaert, Lien; Hagemeyer, Christoph E; De Geest, Bruno G; Caruso, Frank

    2015-02-01

    Polymer microcapsules are of particular interest for applications including self-healing coatings, catalysis, bioreactions, sensing, and drug delivery. The primary way that polymer capsules can exhibit functionality relevant to these diverse fields is through the incorporation of functional cargo in the capsule cavity or wall. Diverse functional and therapeutic cargo can be loaded into polymer capsules with ease using polymer-stabilized calcium carbonate (CaCO 3 ) particles. A variety of examples are demonstrated, including 15 types of cargo, yielding a toolbox with effectively 500+ variations. This process uses no harsh reagents and can take less than 30 min to prepare, load, coat, and form the hollow capsules. For these reasons, it is expected that the technique will play a crucial role across scientific studies in numerous fields.

  1. Method of forming capsules containing a precise amount of material

    Science.gov (United States)

    Grossman, M.W.; George, W.A.; Maya, J.

    1986-06-24

    A method of forming a sealed capsule containing a submilligram quantity of mercury or the like, the capsule being constructed from a hollow glass tube, by placing a globule or droplet of the mercury in the tube. The tube is then evacuated and sealed and is subsequently heated so as to vaporize the mercury and fill the tube therewith. The tube is then separated into separate sealed capsules by heating spaced locations along the tube with a coiled heating wire means to cause collapse spaced locations there along and thus enable separation of the tube into said capsules. 7 figs.

  2. Pathogenesis of Human Diffusely Adhering Escherichia coli Expressing Afa/Dr Adhesins (Afa/Dr DAEC): Current Insights and Future Challenges

    Science.gov (United States)

    2014-01-01

    SUMMARY The pathogenicity and clinical pertinence of diffusely adhering Escherichia coli expressing the Afa/Dr adhesins (Afa/Dr DAEC) in urinary tract infections (UTIs) and pregnancy complications are well established. In contrast, the implication of intestinal Afa/Dr DAEC in diarrhea is still under debate. These strains are age dependently involved in diarrhea in children, are apparently not involved in diarrhea in adults, and can also be asymptomatic intestinal microbiota strains in children and adult. This comprehensive review analyzes the epidemiology and diagnosis and highlights recent progress which has improved the understanding of Afa/Dr DAEC pathogenesis. Here, I summarize the roles of Afa/Dr DAEC virulence factors, including Afa/Dr adhesins, flagella, Sat toxin, and pks island products, in the development of specific mechanisms of pathogenicity. In intestinal epithelial polarized cells, the Afa/Dr adhesins trigger cell membrane receptor clustering and activation of the linked cell signaling pathways, promote structural and functional cell lesions and injuries in intestinal barrier, induce proinflammatory responses, create angiogenesis, instigate epithelial-mesenchymal transition-like events, and lead to pks-dependent DNA damage. UTI-associated Afa/Dr DAEC strains, following adhesin-membrane receptor cell interactions and activation of associated lipid raft-dependent cell signaling pathways, internalize in a microtubule-dependent manner within urinary tract epithelial cells, develop a particular intracellular lifestyle, and trigger a toxin-dependent cell detachment. In response to Afa/Dr DAEC infection, the host epithelial cells generate antibacterial defense responses. Finally, I discuss a hypothetical role of intestinal Afa/Dr DAEC strains that can act as “silent pathogens” with the capacity to emerge as “pathobionts” for the development of inflammatory bowel disease and intestinal carcinogenesis. PMID:25278576

  3. Video-based measurements for wireless capsule endoscope tracking

    International Nuclear Information System (INIS)

    Spyrou, Evaggelos; Iakovidis, Dimitris K

    2014-01-01

    The wireless capsule endoscope is a swallowable medical device equipped with a miniature camera enabling the visual examination of the gastrointestinal (GI) tract. It wirelessly transmits thousands of images to an external video recording system, while its location and orientation are being tracked approximately by external sensor arrays. In this paper we investigate a video-based approach to tracking the capsule endoscope without requiring any external equipment. The proposed method involves extraction of speeded up robust features from video frames, registration of consecutive frames based on the random sample consensus algorithm, and estimation of the displacement and rotation of interest points within these frames. The results obtained by the application of this method on wireless capsule endoscopy videos indicate its effectiveness and improved performance over the state of the art. The findings of this research pave the way for a cost-effective localization and travel distance measurement of capsule endoscopes in the GI tract, which could contribute in the planning of more accurate surgical interventions. (paper)

  4. Video-based measurements for wireless capsule endoscope tracking

    Science.gov (United States)

    Spyrou, Evaggelos; Iakovidis, Dimitris K.

    2014-01-01

    The wireless capsule endoscope is a swallowable medical device equipped with a miniature camera enabling the visual examination of the gastrointestinal (GI) tract. It wirelessly transmits thousands of images to an external video recording system, while its location and orientation are being tracked approximately by external sensor arrays. In this paper we investigate a video-based approach to tracking the capsule endoscope without requiring any external equipment. The proposed method involves extraction of speeded up robust features from video frames, registration of consecutive frames based on the random sample consensus algorithm, and estimation of the displacement and rotation of interest points within these frames. The results obtained by the application of this method on wireless capsule endoscopy videos indicate its effectiveness and improved performance over the state of the art. The findings of this research pave the way for a cost-effective localization and travel distance measurement of capsule endoscopes in the GI tract, which could contribute in the planning of more accurate surgical interventions.

  5. Medical capsule robots: A renaissance for diagnostics, drug delivery and surgical treatment.

    Science.gov (United States)

    Mapara, Sanyat S; Patravale, Vandana B

    2017-09-10

    The advancements in electronics and the progress in nanotechnology have resulted in path breaking development that will transform the way diagnosis and treatment are carried out currently. This development is Medical Capsule Robots, which has emerged from the science fiction idea of robots travelling inside the body to diagnose and cure disorders. The first marketed capsule robot was a capsule endoscope developed to capture images of the gastrointestinal tract. Today, varieties of capsule endoscopes are available in the market. They are slightly larger than regular oral capsules, made up of a biocompatible case and have electronic circuitry and mechanisms to capture and transmit images. In addition, robots with diagnostic features such as in vivo body temperature detection and pH monitoring have also been launched in the market. However, a multi-functional unit that will diagnose and cure diseases inside the body has not yet been realized. A remote controlled capsule that will undertake drug delivery and surgical treatment has not been successfully launched in the market. High cost, inadequate power supply, lack of control over drug release, limited space for drug storage on the capsule, inadequate safety and no mechanisms for active locomotion and anchoring have prevented their entry in the market. The capsule robots can revolutionize the current way of diagnosis and treatment. This paper discusses in detail the applications of medical capsule robots in diagnostics, drug delivery and surgical treatment. In diagnostics, detailed analysis has been presented on wireless capsule endoscopes, issues associated with the marketed versions and their corresponding solutions in literature. Moreover, an assessment has been made of the existing state of remote controlled capsules for targeted drug delivery and surgical treatment and their future impact is predicted. Besides the need for multi-functional capsule robots and the areas for further research have also been

  6. Research on choleretic effect of menthol, menthone, pluegone, isomenthone, and limonene in DanShu capsule.

    Science.gov (United States)

    Hu, Guanying; Yuan, Xing; Zhang, Sanyin; Wang, Ruru; Yang, Miao; Wu, Chunjie; Wu, Zhigang; Ke, Xiao

    2015-02-01

    Danshu capsule (DSC) is a medicinal compound in traditional Chinese medicine (TCM). It is commonly used for the treatment of acute & chronic cholecystitis as well as choleithiasis. To study its choleretic effect, healthy rats were randomly divided into DSC high (DSCH, 900mg/kg), medium (DSCM, 450mg/kg), and low (DSCL, 225mg/kg) group, Xiaoyan Lidan tablet (XYLDT, 750mg/kg), and saline group. The bile was collected for 1h after 20-minute stabilization as the base level, and at 1h, 2h, 3h, and 4h after drug administration, respectively. Bile volume, total cholesterol, and total bile acid were measured at each time point. The results revealed that DSC significantly stimulated bile secretion, decreased total cholesterol level and increased total bile acid level. Therefore, it had choleretic effects. To identify the active components contributing to its choleretic effects, five major constituents which are menthol (39.33mg/kg), menthone (18.02mg/kg), isomenthone (8.18mg/kg), pluegone (3.31mg/kg), and limonene (4.39mg/kg) were tested on our rat model. The results showed that menthol and limonene could promote bile secretion when compared to DSC treatment (p > 0.05); Menthol, menthol and limonene could significantly decrease total cholesterol level (plimonene. Crown Copyright © 2014. Published by Elsevier B.V. All rights reserved.

  7. The effect of glicerol and sorbitol plasticizers toward disintegration time of phyto-capsules

    Science.gov (United States)

    Pudjiastuti, Pratiwi; Hendradi, Esti; Wafiroh, Siti; Harsini, Muji; Darmokoesoemo, Handoko

    2016-03-01

    The aim of research is determining the effect of glycerol and sorbitol toward the disintegration time of phyto-capsules, originated capsules from plant polysaccharides. Phyto-capsules were made from polysaccharides and 0.5% (v/v) of glycerol and sorbitol of each. The seven capsules of each were determined the disintegration time using Erweka disintegrator. The mean of disintegration time of phyto-capsules without plasticizers, with glycerol and sorbitol were 25'30"; 45'15" and 35'30" respectively. The color and colorless gelatin capsules showed the mean of disintegration time 7'30" and 2'35" respectively.

  8. Alginate/sodium caseinate aqueous-core capsules: a pH-responsive matrix.

    Science.gov (United States)

    Ben Messaoud, Ghazi; Sánchez-González, Laura; Jacquot, Adrien; Probst, Laurent; Desobry, Stéphane

    2015-02-15

    Alginate capsules have several applications. Their functionality depends considerably on their permeability, chemical and mechanical stability. Consequently, the creation of composite system by addition of further components is expected to control mechanical and release properties of alginate capsules. Alginate and alginate-sodium caseinate composite liquid-core capsules were prepared by a simple extrusion. The influence of the preparation pH and sodium caseinate concentration on capsules physico-chemical properties was investigated. Results showed that sodium caseinate influenced significantly capsules properties. As regards to the membrane mechanical stability, composite capsules prepared at pH below the isoelectric point of sodium caseinate exhibited the highest surface Young's modulus, increasing with protein content, explained by potential electrostatic interactions between sodium caseinate amino-groups and alginate carboxylic group. The kinetic of cochineal red A release changed significantly for composite capsules and showed a pH-responsive release. Sodium caseinate-dye mixture studied by absorbance and fluorescence spectroscopy confirmed complex formation at pH 2 by electrostatic interactions between sodium caseinate tryptophan residues and cochineal red sulfonate-groups. Consequently, the release mechanism was explained by membrane adsorption process. This global approach is useful to control release mechanism from macro and micro-capsules by incorporating guest molecules which can interact with the entrapped molecule under specific conditions. Copyright © 2014 Elsevier Inc. All rights reserved.

  9. From Mxit to Dr Math

    CSIR Research Space (South Africa)

    Botha, Adèle

    2013-02-01

    Full Text Available In 2007, Laurie Butgereit, a researcher at the CSIR Meraka Institute, started to use Mxit as a communication channel to tutor her son in mathematics. Her son and a number of his friends logged in, and Dr Math was born. At the inception of Dr Math...

  10. Pathogenesis of human diffusely adhering Escherichia coli expressing Afa/Dr adhesins (Afa/Dr DAEC): current insights and future challenges.

    Science.gov (United States)

    Servin, Alain L

    2014-10-01

    The pathogenicity and clinical pertinence of diffusely adhering Escherichia coli expressing the Afa/Dr adhesins (Afa/Dr DAEC) in urinary tract infections (UTIs) and pregnancy complications are well established. In contrast, the implication of intestinal Afa/Dr DAEC in diarrhea is still under debate. These strains are age dependently involved in diarrhea in children, are apparently not involved in diarrhea in adults, and can also be asymptomatic intestinal microbiota strains in children and adult. This comprehensive review analyzes the epidemiology and diagnosis and highlights recent progress which has improved the understanding of Afa/Dr DAEC pathogenesis. Here, I summarize the roles of Afa/Dr DAEC virulence factors, including Afa/Dr adhesins, flagella, Sat toxin, and pks island products, in the development of specific mechanisms of pathogenicity. In intestinal epithelial polarized cells, the Afa/Dr adhesins trigger cell membrane receptor clustering and activation of the linked cell signaling pathways, promote structural and functional cell lesions and injuries in intestinal barrier, induce proinflammatory responses, create angiogenesis, instigate epithelial-mesenchymal transition-like events, and lead to pks-dependent DNA damage. UTI-associated Afa/Dr DAEC strains, following adhesin-membrane receptor cell interactions and activation of associated lipid raft-dependent cell signaling pathways, internalize in a microtubule-dependent manner within urinary tract epithelial cells, develop a particular intracellular lifestyle, and trigger a toxin-dependent cell detachment. In response to Afa/Dr DAEC infection, the host epithelial cells generate antibacterial defense responses. Finally, I discuss a hypothetical role of intestinal Afa/Dr DAEC strains that can act as "silent pathogens" with the capacity to emerge as "pathobionts" for the development of inflammatory bowel disease and intestinal carcinogenesis. Copyright © 2014, American Society for Microbiology. All Rights

  11. In Memoriam: Dr. Frank John Fenner

    Centers for Disease Control (CDC) Podcasts

    2011-04-22

    This podcast reflects on one of the greatest pioneers in virology, Dr. Frank John Fenner. Dr. Frederick Murphy, a member of EID's editorial board and the Institute of Medicine, and professor of Pathology at the University of Texas Medical Branch in Galveston, shares professional and personal stories of Dr. Frank Fenner.  Created: 4/22/2011 by National Center for Emerging Zoonotic and Infectious Diseases (NCEZID).   Date Released: 4/26/2011.

  12. Dr. von Braun Briefing Walt Disney

    Science.gov (United States)

    1965-01-01

    Dr. von Braun began his association with Walt Disney in the 1950s when the rocket scientist appeared in three Disney television productions related to the exploration of space. Years later, Dr. von Braun invited Disney and his associates to tour the Marshall Space Flight Center (MSFC) in Huntsville, Alabama. This photograph is dated April 13, 1965. From left are R.J. Schwinghamer from the MSFC, Disney, B.J. Bernight, and Dr. von Braun.

  13. Irradiation capsules VISA-2a-f, chapter VI

    International Nuclear Information System (INIS)

    Pavicevic, M.

    1962-01-01

    Irradiation capsules VISA-2a, b,c,d, and e were constructed in Saclay according to the drawings from Vinca and according to the demand of the experimentators. This chapter VI includes documentation for each type of capsule, review about each experiment within the VISA-2 project, the objective and purpose of the experiment as well as experimental device. Irradiation capsule VISA-2f was placed in the RA reactor core in September 1962. It was completely manufactured in Vinca including sample holders and leak tight shells. It will remain in the reactor core for about month in order to obtain the integral fast neutron flux [sr

  14. Some views on mechanical safety of capsules for radioactive waste

    International Nuclear Information System (INIS)

    Nilsson, F.

    1978-02-01

    Three different concepts for encapsulation of used nuclear fuel are discussed with respect to their mechanical safety. In the first concept the burnt out fuel elements are encapsulated into a copper capsule. The material properties of copper are discussed especially with reference to toughness and creep. A simple fracture mechanical analysis shows that the risk for direct fracture is negligible at the actual stress levels. The loads on the capsule are studied and are found to be normally less than 40 MPa (residual stresses). Transient loads that might arise in the handling of the capsule might however be dangerous to its integrity. The next concept is encapsulation of the fuel elements into a sintered aluminium oxide capsule. A fracture probability analysis based on Weibull's statistical fracture theory gives fracture probabilities that are acceptable. Extended studies of this concept, especially of the risk for delayed fracture, is recommended. The last concept is a Pb-Ti capsule for glassed refined fuel. An analysis of the relaxation of internal stresses is performed. The critical point of these capsules appears to be the welds on the titanium shell where the risk for a direct fracture is not neglibigle

  15. The Antiphagocytic Activity of SeM of Streptococcus equi Requires Capsule.

    Science.gov (United States)

    Timoney, John F; Suther, Pranav; Velineni, Sridhar; Artiushin, Sergey C

    2014-01-01

    Resistance to phagocytosis is a crucial virulence property of Streptococcus equi (Streptococcus equi subsp. equi; Se), the cause of equine strangles. The contribution and interdependence of capsule and SeM to killing in equine blood and neutrophils were investigated in naturally occurring strains of Se. Strains CF32, SF463 were capsule and SeM positive, strains Lex90, Lex93 were capsule negative and SeM positive and strains Se19, Se1-8 were capsule positive and SeM deficient. Phagocytosis and killing of Se19, Se1-8, Lex90 and Lex93 in equine blood and by neutrophils suspended in serum were significantly (P ≤ 0.02) greater compared to CF32 and SF463. The results indicate capsule and SeM are both required for resistance to phagocytosis and killing and that the anti-phagocytic property of SeM is greatly reduced in the absence of capsule.

  16. Experimental Investigation of the Spiral Structure of a Magnetic Capsule Endoscope

    Directory of Open Access Journals (Sweden)

    Wanan Yang

    2016-06-01

    Full Text Available Fitting a wireless capsule endoscope (WCE with a navigation feature can maximize its functional benefits. The rotation of a spiral-type capsule can be converted to translational motion. The study investigated how the spiral structure and rotational speed affected the capsule's translation speed. A hand-held instrument, including two permanent magnets, a stepper motor, a controller and a power supplier, were designed to generate rotational magnetic fields. The surfaces of custom-built permanent magnet rings magnetized radially were mounted in spiral lines with different lead angles and diameters, acting as mock-up capsules. The experimental results demonstrate that the rotational speed of the magnetic field and the spiral have significant effects on the translational speed of a capsule. The spiral line with a larger lead angle and the rotating magnetic field with a higher speed can change the capsule's rotation into a translational motion more efficiently in the intestine.

  17. Effect of Heat Flux on the Specimen Temperature of an LBE Capsule

    International Nuclear Information System (INIS)

    Kang, Y. H.; Park, S. J.; Cho, M. S.; Choo, K. N.; Lee, Y. S.

    2011-01-01

    For application of high-temperature irradiation tests in the HANARO reactor for Gen IV reactor material development, a number of newly designed LBE capsules have been investigated at KAERI since 2008. Recent study on heat transfer experiment of an LBE capsule with a single heater has shown that the specimen temperature of the mock-up increased linearly with an increase of heat input. The work highlighted only the heat transfer capability of an LBE capsule with a single heater as a simulated specimen in a liquid metal medium. Hence, a new LBE capsule with multi specimen sets has been designed and fabricated for the heat transfer experiment of an LBE capsule of 11M-01K. In this paper, a series of thermal analyses and heat transfer experiments for a newly designed LBE capsule was implemented to study the effect of an increase in the value of heat input and its influence on temperature distribution in the capsule mock-up

  18. A pharmacokinetic analysis of diclofenac potassium soft-gelatin capsule in patients after bunionectomy.

    Science.gov (United States)

    Kowalski, Mark; Stoker, Douglas G; Bon, Charles; Moore, Keith A; Boesing, Stephen E

    2010-01-01

    The clinical utility of diclofenac potassium, a nonsteroidal anti-inflammatory drug, may be lessened by inconsistent gastrointestinal absorption. Diclofenac potassium liquid filled soft-gelatin capsule (DPSGC) is an investigational formulation that uses ProSorb dispersion technology to facilitate rapid and consistent gastrointestinal absorption. In this study, the pharmacokinetic (PK) properties of DPSGC are investigated and compared with a commercially available oral diclofenac potassium tablet in patients after primary unilateral first metatarsal bunionectomy. In an open-label, randomized study, 53 patients received ProSorb-D 12.5 mg (the liquid equivalent of DPSGC), DPSGC 25 mg, DPSGC 50 mg, or immediate-release diclofenac potassium 50-mg tablet administered every 8 hours for a 24-hour inpatient period followed by 7 days of outpatient dosing. Diclofenac steady-state PK was evaluated over an 8-hour sampling period 4 days after surgery. Delayed and/or multiple peaks in the diclofenac plasma concentration-time course profiles occurred more frequently with the commercially available oral diclofenac potassium 50-mg tablet than with the other DPSGC formulations. PK data for ProSorb-D 12.5-mg liquid, DPSGC 25 mg, DPSGC 50 mg, and diclofenac potassium 50-mg tablet revealed mean peak plasma concentrations (Cmax) of 302, 749, 1006, and 902 ng/mL, respectively, whereas area under the plasma concentration curve values were 316, 595, 1029, and 1166 ng-hour/mL, respectively. Mean times to Cmax (tmax) were 0.49, 0.63, 0.95, and 1.26 h, respectively. When compared with absorption characteristics of diclofenac potassium 50-mg tablet, DPSGC was more rapidly and consistently absorbed after bunionectomy. These characteristics should be advantageous when rapid pain relief is desired.

  19. Adhesive capsulitis of the shoulder: evaluation with MR arthrography

    International Nuclear Information System (INIS)

    Jung, Joon-Yong; Jee, Won-Hee; Chun, Ho Jong; Kim, Yang-Soo; Chung, Yang Guk; Kim, Jung-Man

    2006-01-01

    The purpose of this study was to determine the usefulness of magnetic resonance (MR) arthrography for diagnosing adhesive capsulitis. Shoulder MR images of 28 patients with (n=14) and without (n=14) adhesive capsulitis were retrospectively analyzed. MR images were assessed for capsule and synovium thickness as well as the width of the axillary recess on oblique coronal fat-suppressed T1-weighted images and T2-weighted images, respectively. On oblique sagittal fat-suppressed T1-weighted images, the width of the rotator interval and the presence of abnormal tissue in the interval were evaluated. Significant differences were found between the two groups in capsule and synovium thickness on both sides of the recess on oblique coronal T2-weighted images (P=0.000), whereas thickness on the humeral aspect showed no significant difference on oblique coronal fat-suppressed T1-weighted images (P=0.109). On oblique coronal T2-weighted images, a cut-off value of 3-mm thickness gave the highest diagnostic accuracy for adhesive capsulitis with sensitivity, specificity, and accuracy of 79% (11/14), 100% (14/14), and 89% (25/28) at the humeral side and 93% (13/14), 86% (12/14), and 89% (25/28) at the glenoid side, respectively. There were significant differences in rotator interval width, presence of abnormal tissue in the rotator interval, and axillary recess width between the two groups (P<0.05). Thickness of capsule and synovium of the axillary recess greater than 3 mm is a practical MR criterion for diagnosing adhesive capsulitis when measured on oblique coronal T2-weighted MR arthrography images without fat suppression. The presence of abnormal tissue in the rotator interval showed high sensitivity but rather low specificity. (orig.)

  20. Wireless powered capsule endoscopy for colon diagnosis and treatment

    International Nuclear Information System (INIS)

    Chen, Wenwen; Yan, Guozheng; He, Shu; Ke, Quan; Wang, Zhiwu; Liu, Hua; Jiang, Pingping

    2013-01-01

    This paper presents a wireless power transfer system integrated with an active locomotion and biopsy module in an endoscopic capsule for colon inspection. The capsule, which can move automatically, is designed for non-invasive biopsy and visual inspection of the intestine. To supply enough power for multiple functions and ensure safety for the human body, the efficiency of the current power transmission system needs to be improved. To take full advantage of the volume in the capsule body, a novel structure of receiving coils wound on a multi-core of MnZn ferrite hollow cylinder was used; with this new core, the efficiency increased to more than 7.98%. Up to 1.4 W of dc power can be delivered to the capsule as it travels along the gastrointestinal tract. Three micro motors were integrated for pumping, anchoring, locomotion and biopsy. A user interface and RF communication enables the operator to drive the capsule in an intuitive manner. To gauge the efficacy of the wireless power supply in a simulated real-world application, the biopsy and locomotion capabilities of the device were successfully tested in a slippery, soft tube and gut environment in vitro. (paper)

  1. Chord length distribution for a compound capsule

    International Nuclear Information System (INIS)

    Pitřík, Pavel

    2017-01-01

    Chord length distribution is a factor important in the calculation of ionisation chamber responses. This article describes Monte Carlo calculations of the chord length distribution for a non-convex compound capsule. A Monte Carlo code was set up for generation of random chords and calculation of their lengths based on the input number of generations and cavity dimensions. The code was written in JavaScript and can be executed in the majority of HTML viewers. The plot of occurrence of cords of different lengths has 3 peaks. It was found that the compound capsule cavity cannot be simply replaced with a spherical cavity of a triangular design. Furthermore, the compound capsule cavity is directionally dependent, which must be taken into account in calculations involving non-isotropic fields of primary particles in the beam, unless equilibrium of the secondary charged particles is attained. (orig.)

  2. Comparative assessment of hepatic Glisson's capsule and bovine pericardium in heart valve bioprostheses.

    Science.gov (United States)

    Kagramanov, I I; Kokshenev, I V; Dobrova, N B; Kastava, V T; Serov, R A; Zaets, S B

    1998-05-01

    The optimal material for heart valve bioprostheses remains disputable. This investigation was initiated to compare the properties of hepatic Glisson's capsule, clinical experience of which in cardiovascular surgery is minimal, with those of bovine pericardium. Hepatic Glisson's capsule was harvested from bull calves and used to create composite pulmonary arterial monocusp grafts and bioprostheses. Comparison of the strength and elastic properties of Glisson's capsule and bovine pericardium, as well as the hydrodynamic characteristics of valves made from these materials, was performed. Late results of operations using these materials were estimated echocardiographically. Although Glisson's capsule tissue is thinner than the bovine pericardium, its elasticity modulus is greater. However, the hydrodynamic characteristics of heart valves made from either tissue are similar. Moreover, valves made from Glisson's capsule have a lower systolic pressure gradient on the prosthesis and a higher effective orifice area. Composite pulmonary arterial xenopericardial grafts with a monocusp of Glisson's capsule were used in 30 patients during tetralogy of Fallot repair. Glisson's capsule was also used for tricuspid valve reconstruction and as a bioprosthesis in six patients with Ebstein's anomaly. At 1-2 years after surgery, the Glisson's capsule tissue remained thin and flexible, with no calcification. Although the hydrodynamic properties of hepatic Glisson's capsule and the bovine pericardium are similar, the capsule tissue is thinner and has a greater elasticity modulos. Thus, Glisson's capsule may be used for bioprosthesis construction both independently and in combination with bovine pericardium.

  3. Capsule Performance Optimization for the National Ignition Facility

    Science.gov (United States)

    Landen, Otto

    2009-11-01

    The overall goal of the capsule performance optimization campaign is to maximize the probability of ignition by experimentally correcting for likely residual uncertainties in the implosion and hohlraum physics used in our radiation-hydrodynamic computational models before proceeding to cryogenic-layered implosions and ignition attempts. This will be accomplished using a variety of targets that will set key laser, hohlraum and capsule parameters to maximize ignition capsule implosion velocity, while minimizing fuel adiabat, core shape asymmetry and ablator-fuel mix. The targets include high Z re-emission spheres setting foot symmetry through foot cone power balance [1], liquid Deuterium-filled ``keyhole'' targets setting shock speed and timing through the laser power profile [2], symmetry capsules setting peak cone power balance and hohlraum length [3], and streaked x-ray backlit imploding capsules setting ablator thickness [4]. We will show how results from successful tuning technique demonstration shots performed at the Omega facility under scaled hohlraum and capsule conditions relevant to the ignition design meet the required sensitivity and accuracy. We will also present estimates of all expected random and systematic uncertainties in setting the key ignition laser and target parameters due to residual measurement, calibration, cross-coupling, surrogacy, and scale-up errors, and show that these get reduced after a number of shots and iterations to meet an acceptable level of residual uncertainty. Finally, we will present results from upcoming tuning technique validation shots performed at NIF at near full-scale. Prepared by LLNL under Contract DE-AC52-07NA27344. [4pt] [1] E. Dewald, et. al. Rev. Sci. Instrum. 79 (2008) 10E903. [0pt] [2] T.R. Boehly, et. al., Phys. Plasmas 16 (2009) 056302. [0pt] [3] G. Kyrala, et. al., BAPS 53 (2008) 247. [0pt] [4] D. Hicks, et. al., BAPS 53 (2008) 2.

  4. Thermal analysis of an instrumented capsule using an ANSYS program

    International Nuclear Information System (INIS)

    Choi, Myoung Hwan; Choo, Kee Nam; Kang, Young Hwan; Cho, Man Soon; Sohn, Jae Min; Kim, Bong Goo

    2006-01-01

    An instrumented capsule has been used for an irradiation test of various nuclear materials in the research reactor, HANARO. To obtain the design data of the instrumented capsule, a thermal analysis is performed using a finite element analysis program, ANSYS. The 2-dimensional model for a cross section of the capsule including the specimens is generated, and a gamma-heating rate of the materials for the HANARO power of 24 or 30 MW is considered as an input force. The effect of the gap size and the control rod position on the temperature of the specimens or other components is discussed. From the analysis it is found that the gap between the thermal media and the external tube has a significant effect on the temperature of the specimen. In the case of the material capsule, the maximum temperature for the reactor power of 24 MW is 255degC for an irradiation test and 257degC for a FE analysis at the center stage of the capsule in the axial direction. It is expected that the analysis models using an ANSYS program will be useful in designing the instrumented capsules for an irradiation test and estimating the test results. (author)

  5. Safety Analysis Report for Primary Capsule of Ir-192 Radiation Source

    International Nuclear Information System (INIS)

    Lee, J. C.; Bang, K. S.; Choi, W. S.; Seo, K. S.; Son, K. J.; Park, W. J.

    2008-12-01

    All of the source capsules to transport a special form radioactive material should be designed and fabricated in accordance with the design criteria prescribed in IAEA standards and domestic regulations. The objective of this project is to prove the safety of a primary capsule for Ir-192 radiation source which produced in the HANARO. The safety tests of primary capsules were carried out for the impact, percussion and heat conditions. And leakage tests were carried out before and after the each tests. The capsule showed slight scratches and their deformations were not found after each tests. It also met the allowable limits of leakage rate after each test. Therefore, it has been verified that the capsule was designed and fabricated to meet all requirements for the special form radioactive materials

  6. Therapeutic applications of radioactive 131iodine: Procedures and incidents with capsules

    International Nuclear Information System (INIS)

    Al Aamri, Marwa; Ravichandran, Ramamoorthy; Binukumar, John Pichy; Al Balushi, Naima

    2016-01-01

    Treatments for thyrotoxicosis and carcinoma thyroid are carried out by oral administration of radioactive iodine ( 131 I) in the form of liquid or capsules. The liquid form of 131 I has higher risk factors such as vapourization, spillage and need for management of higher activity wastes. Use of 131 I in capsule form simplify procedures of handling compared to liquid form of 131 I. The guidelines of safe handling and quality assurance aspects for therapeutic use 131 I are well outlined by International Atomic Energy Agency (IAEA) reports. A few unusual incidents with I-131 capsules encountered in the past need to be highlighted from health physics point of view. In Royal Hospital, Oman, I-131 is imported in capsules, and the total activity handled/year steadily increased over 10 years. Discrete activities range from 185 MBq (5 mCi) up to 7.4 GBq (200 mCi). In four incidents deviations in standard operational procedures were recorded. Nature of incidents is described as follows: (1) After assay of activity, the capsule was directly put in the lead container with missing of inner cap. (2) Patient poured water in the Perspex tube, when the capsule was handed over to her, making an emergency situation. (3) In 3 high activity capsules (2 nos 2.96 GBq, 1 no. 4.26 GBq), observed sticky behavior in capsule holder on the 2 nd day post receipt, which were in order on the 1 st day. (4) A capsule could not be swallowed by a patient, which was taken back from the mouth. Monitoring of patient later did not show residual ingested activity. The report documents some of the unusual incidents for information to other centers engaged in such radioactive administrations

  7. Performance indicators for carrier-based DPIs: Carrier surface properties for capsule filling and API properties for in vitro aerosolisation.

    Science.gov (United States)

    Faulhammer, E; Zellnitz, S; Wutscher, T; Stranzinger, S; Zimmer, A; Paudel, A

    2018-01-30

    This study investigates engineered carrier, as well as engineered API particles, and shows that there are distinct performance indicators of particle engineering for carrier-based dry powder inhalers (DPIs). Spray dried (SDSS) and jet-milled (JMSS) salbutamol sulphate (SS) was blended with untreated α-lactose monohydrate (LAC_R) and α-lactose monohydrate engineered (LAC_E). Subsequent capsule filling was performed with different process settings on a dosator nozzle capsule filling machine in order to reach a target fill weight of 20-25 mg. To evaluate the performance of the different mixtures, in vitro lung deposition experiments were carried out with a next generation impactor, the emitted dose (ED) and fine particle fraction (FPF) were calculated based on the specification of the European pharmacopoeia. The FPF of micronised powder blends is significantly higher (20%) compared to the FPF of spray dried blends (5%). Compared to API engineering, carrier engineering had a positive effect on the capsule filling performance (weight variability and mean fill weight) at lower compression ratios (setting 1). Results further showed that higher compression ratios appear to be beneficial in terms of capsule filling performance (higher fill weight and less fill weight variation). Concluding, it can be stated that the carrier engineering, or generally carrier properties, govern downstream processing, whereas the API engineering and API properties govern the aerosolisation performance and thereby significantly affect the dose delivery to the lungs. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Myofibroblast Numbers are Elevated in Human Elbow Capsules After Trauma

    OpenAIRE

    Hildebrand, Kevin A.; Zhang, Mei; van Snellenberg, Wistara; King, Graham J. W.; Hart, David A.

    2004-01-01

    Elbow contractures, a frequent problem after injury, can be treated by excision of the joint capsule. However, the underlying changes in the joint capsule are poorly understood. Based on skin healing work, we examined the hypotheses that myofibroblast numbers and expression of a myofibroblast marker α-smooth muscle actin, are elevated in patients with posttraumatic joint contractures. Anterior capsules were obtained from six patients who had operative release of posttraumatic contractures gre...

  9. Separation of DR synthesized Ti-Mg Alloy by dissolution of waste by-products in acid media

    CSIR Research Space (South Africa)

    Mushove, T

    2010-06-01

    Full Text Available The objective of this work is to isolate synthesized Ti-Mg alloy powder through leaching out of MgO and any unreduced oxides of Titanium. Leaching media investigated are H2SO4, HCl and organic acids ascorbic acid/oxalic and L-cysteine /ascorbic...

  10. Fabrication of Non-instrumented capsule for DUPIC simulated fuel irradiation test in HANARO

    Energy Technology Data Exchange (ETDEWEB)

    Kim, B.G.; Kang, Y.H.; Park, S.J.; Shin, Y.T. [Korea Atomic Energy Research Institute, Taejon (Korea)

    1999-10-01

    In order to develope DUPIC nuclear fuel, the irradiation test for simulated DUPIC fuel was planed using a non-instrumented capsule in HANARO. Because DUPIC fuel is highly radioactive material the non-instrumented capsule for an irradiation test of simulated DUPIC fuel in HANARO was designed to remotely assemble and disassemble in hot cell. And then, according to the design requirements the non-instrumented DUPIC capsule was successfully manufactured. Also, the manufacturing technologies of the non-instrumented capsule for irradiating the nuclear fuel in HANARO were established, and the basic technology for the development of the instrumented capsule technology was accumulated. This report describes the manufacturing of the non-instrumented capsule for simulated DUPIC fuel. And, this report will be based to develope the instrumented capsule, which will be utilized to irradiate the nuclear fuel in HANARO. 26 refs., 4 figs. (Author)

  11. Associations Between Egg Capsule Morphology and Predation Among Populations of the Marine Gastropod, Nucella emarginata.

    Science.gov (United States)

    Rawlings, T A

    1990-12-01

    Intraspecific variation in the morphology of egg capsules is ideal for assessing the costs and benefits of encapsulation, yet little is known about the extent of such variation among populations of a single species. In the present study, I compared capsule morphology among three populations of the intertidal gastropod, Nucella emarginata. Significant differences were found both in capsule wall thickness and capsule strength. Mean capsule wall thickness varied as much as 25% among populations, with the dry weight of capsular cases differing accordingly. Capsule strength, measured as resistance to puncturing and squeezing forces, also varied among populations, but did not directly reflect differences in capsule wall thickness. Despite extensive variation in capsule morphology within this species, the number and size of eggs contained within capsules of equal volume did not differ significantly among populations. I also compared the type of capsule-eating predators that were present at each site. Shore crabs, Hemigrapsus spp., were abundant at all three sites; however, the predatory isopods Idotea wosnesenskii were only present at sites containing relatively thick-walled capsules. Although Hemigrapsus and Idotea were able to chew through both thick- and thin-walled capsules, laboratory experiments revealed that Idotea preferentially opened thin-walled capsules. These results suggest that variation in capsule morphology among populations of N. emarginata may, at least in part, reflect selection for the protection of embryos against predation.

  12. Factors affecting capsule size and production by lactic acid bacteria used as dairy starter cultures.

    Science.gov (United States)

    Hassan, A N; Frank, J F; Shalabi, S I

    2001-02-28

    The effects of sugar substrates on capsule size and production by some capsule-forming nonropy and ropy dairy starter cultures were studied. Test sugars (glucose, lactose, galactose, or sucrose) were used as a sole carbohydrate source and the presence of a capsule and its size were determined by using confocal scanning laser microscopy. Nonropy strains produced maximum capsule size when grown in milk. Strains that did not produce capsules in milk did not produce them in any other growth medium. Specific sugars required for capsule production were strain-dependent. Increasing lactose content of Elliker broth from 0.5 to 5% or adding whey protein or casein digest produced larger capsules. Whey protein concentrate stimulated production of larger capsules than did casamino acids or casitone. Some Streptococcus thermophilus strains produced capsules when grown on galactose only. Nonropy strains of Lactobacillus delbrueckii subsp. bulgaricus produced capsules on lactose, but not on glucose. A ropy strain of Lactobacillus delbrueckii subsp. bulgaricus produced a constant capsule size regardless of the growth medium. The ability of some strains of Streptococcus thermophilus to use galactose in capsule production could reduce browning of mozzarella cheese during baking by removing a source of reducing sugar. Media that do not support capsule production may improve cell harvesting.

  13. First beryllium capsule implosions on the National Ignition Facility

    Energy Technology Data Exchange (ETDEWEB)

    Kline, J. L.; Yi, S. A.; Simakov, A. N.; Olson, R. E.; Wilson, D. C.; Kyrala, G. A.; Perry, T. S.; Batha, S. H.; Zylstra, A. B. [Los Alamos National Laboratory, Los Alamos, New Mexico 87544 (United States); Dewald, E. L.; Tommasini, R.; Ralph, J. E.; Strozzi, D. J.; MacPhee, A. G.; Callahan, D. A.; Hinkel, D. E.; Hurricane, O. A.; Milovich, J. L.; Rygg, J. R.; Khan, S. F. [Lawrence Livermore National Laboratory, Livermore, California 94550 (United States); and others

    2016-05-15

    The first indirect drive implosion experiments using Beryllium (Be) capsules at the National Ignition Facility confirm the superior ablation properties and elucidate possible Be-ablator issues such as hohlraum filling by ablator material. Since the 1990s, Be has been the preferred Inertial Confinement Fusion (ICF) ablator because of its higher mass ablation rate compared to that of carbon-based ablators. This enables ICF target designs with higher implosion velocities at lower radiation temperatures and improved hydrodynamic stability through greater ablative stabilization. Recent experiments to demonstrate the viability of Be ablator target designs measured the backscattered laser energy, capsule implosion velocity, core implosion shape from self-emission, and in-flight capsule shape from backlit imaging. The laser backscatter is similar to that from comparable plastic (CH) targets under the same hohlraum conditions. Implosion velocity measurements from backlit streaked radiography show that laser energy coupling to the hohlraum wall is comparable to plastic ablators. The measured implosion shape indicates no significant reduction of laser energy from the inner laser cone beams reaching the hohlraum wall as compared with plastic and high-density carbon ablators. These results indicate that the high mass ablation rate for beryllium capsules does not significantly alter hohlraum energetics. In addition, these data, together with data for low fill-density hohlraum performance, indicate that laser power multipliers, required to reconcile simulations with experimental observations, are likely due to our limited understanding of the hohlraum rather than the capsule physics since similar multipliers are needed for both Be and CH capsules as seen in experiments.

  14. Potential of sago starch/carrageenan mixture as gelatin alternative for hard capsule material

    Science.gov (United States)

    Poeloengasih, Crescentiana Dewi; Pranoto, Yudi; Anggraheni, Frida Dwi; Marseno, Djagal Wiseso

    2017-03-01

    In order to replace gelatin in capsule shell production, blends of sago starch and carrageenan were developed. Films and capsules were prepared with 10% (w/v) of sago starch, 25% (w/w starch) of glycerol and various carrageenan concentration (1, 2, 3% w/w starch) in two different kappa/iota-carrageenan ratio (1:3 and 3:1). The resulted films and capsules were characterized by mechanical property, water vapor and oxygen permeability. In addition, moisture absorption and solubility of capsule in acid solution were investigated. The results reveal that addition of carrageenan makes the films stronger and less permeable. Higher kappa-carrageenan content improved tensile strength and barrier properties of the films, whereas higher iota-carrageenan content produced films with higher elongation, moisture absorption and capsule solubility in acid solution. Capsule with 2% (w/w starch) of carrageenan at kappa-/iota-ratio 3:1 had the lowest moisture absorption, whereas capsule with 3% (w/w starch) of carrageenan at kappa/iota ratio 1:3 had the highest solubility. It is illustrated that sago starch/carrageenan blends can be used as hard capsule material.

  15. Learning to Diagnose Cirrhosis with Liver Capsule Guided Ultrasound Image Classification

    Directory of Open Access Journals (Sweden)

    Xiang Liu

    2017-01-01

    Full Text Available This paper proposes a computer-aided cirrhosis diagnosis system to diagnose cirrhosis based on ultrasound images. We first propose a method to extract a liver capsule on an ultrasound image, then, based on the extracted liver capsule, we fine-tune a deep convolutional neural network (CNN model to extract features from the image patches cropped around the liver capsules. Finally, a trained support vector machine (SVM classifier is applied to classify the sample into normal or abnormal cases. Experimental results show that the proposed method can effectively extract the liver capsules and accurately classify the ultrasound images.

  16. Improvement and utilization of irradiation capsule technology in HANARO

    International Nuclear Information System (INIS)

    Choo, Kee-Nam; Cho, Man-Soon; Kim, Bong-Goo; Lee, Cheol-Yong; Yang, Sung-Woo; Shin, Yoon-Taek; Park, Seng-Jae; Jung, Hoan-Sung

    2012-01-01

    Several improvements of irradiation capsule technology regarding irradiation test parameters, such as temperature and neutron flux/fluence, and regarding instrumentation have progressed at HANARO since the last KAERI-JAERI joint seminar held in 2008. The standard HANARO capsule technology that was developed for use in a commercial power plant temperature of about 300degC was improved to apply to a temperature range of 100-1000degC for the irradiation test of materials of new research reactors and future nuclear systems. Low-flux and long-term irradiation technologies have been developed at HANARO. As a beginning step of the localization of capsule instrumentation technology, the irradiation performance of a domestically produced thermocouple and LVDT will be examined at HANARO. The accuracy of an evaluation of neutron fluence and precise welding technology are also being examined at HANARO. Based on these accumulated capsule technologies, a HANARO irradiation capsule system is being actively utilized for the national R and D programme on commercial nuclear reactors and nuclear fuel cycle technology in Korea. HANARO has recently started the irradiation support of R and D relevant to future nuclear systems including SMART, VHTR, and SFR, and HANARO is preparing new support relevant to new research and Fusion reactors. (author)

  17. Thermohydraulic design of saturated temperature capsule for IASCC irradiation test

    International Nuclear Information System (INIS)

    Ide, Hiroshi; Matsui, Yoshinori; Itabashi, Yukio

    2002-10-01

    An advanced water chemistry controlled irradiation research device is being developed in JAERI, to perform irradiation tests for irradiation assisted stress corrosion cracking (IASCC) research concerned with aging of LWR. This device enables the irradiation tests under the water chemistry condition and the temperature, which simulate the conditions for BWR core internals. The advanced water chemistry controlled irradiation research device is composed of saturated temperature capsule inserted into the JMTR core and the water chemistry control unit installed in the reactor building. Regarding the saturated temperature capsule, the Thermohydraulic design of capsule structure was done, aimed at controlling the specimen's temperature, feeding water velocity on specimen's surface to the environment of BWR nearer. As the result of adopting the new capsule structure based on the design study, it was found out that feeding water velocity at the surface of specimen's is increased to about 10 times as much as before, and nuclear heat generated in the capsule components can be removed safely even in the abnormal event such as the case of loss of feeding water. (author)

  18. Thermohydraulic design of saturated temperature capsule for IASCC irradiation test

    Energy Technology Data Exchange (ETDEWEB)

    Ide, Hiroshi; Matsui, Yoshinori; Itabashi, Yukio [Japan Atomic Energy Research Inst., Oarai, Ibaraki (Japan). Oarai Research Establishment] [and others

    2002-10-01

    An advanced water chemistry controlled irradiation research device is being developed in JAERI, to perform irradiation tests for irradiation assisted stress corrosion cracking (IASCC) research concerned with aging of LWR. This device enables the irradiation tests under the water chemistry condition and the temperature, which simulate the conditions for BWR core internals. The advanced water chemistry controlled irradiation research device is composed of saturated temperature capsule inserted into the JMTR core and the water chemistry control unit installed in the reactor building. Regarding the saturated temperature capsule, the Thermohydraulic design of capsule structure was done, aimed at controlling the specimen's temperature, feeding water velocity on specimen's surface to the environment of BWR nearer. As the result of adopting the new capsule structure based on the design study, it was found out that feeding water velocity at the surface of specimen's is increased to about 10 times as much as before, and nuclear heat generated in the capsule components can be removed safely even in the abnormal event such as the case of loss of feeding water. (author)

  19. Adhesive capsulitis: contrast-enhansed shoulder MRI findings

    International Nuclear Information System (INIS)

    Gokalp, Gokhan; Yildirim, Nalan; Yazici, Zeynep; Algin, Oktay

    2011-01-01

    Full text: Evaluation of contrast-enhanced magnetic resonance imaging (CE-MRI) findings in cases clinically diagnosed as adhesive capsulitis (AC). CE-MRI images of 12 cases diagnosed as AC (13 shoulder joints) and nine control cases were retrospectively evaluated. AC diagnosis was establlished based on the history and clinical symptoms. MR signal intensity changes in the axillary pouch, rotator interval, biceps anchor and anterior posterior capsules were analysed with regard to the presence of abnormal soft tissue and contrast enhancement. Capsular and synovial thickening were measured in the axillary recess and rotator interval on coronal oblique CE T1-weighted images. Patient and control groups were compared by Fisher's exact and McNemar tests in terms of signal intensity changes and contrast enhancement in the described areas. Results: Comparison of the group with AC and the control group regarding intensity changes showed a statistically significant difference in the axillary pouch (P 0.05). Comparison of AC and control groups in terms of contrast enhancement revealed statistically significant differences in the axillary pouch, rotator interval, biceps anchor and anterior-posterior capsules (P < 0.001). A significant difference was determined between the AC and control groups with regard to thickening in axillary pouch and rotator interval (P < 0.001). CE studies are useful for diagnosis of AC as it demonstrates thickening of specific soft-tissue areas like joint capsule and synovium.

  20. Criteria for cesium capsules to be shipped as special form radioactive material

    International Nuclear Information System (INIS)

    Lundeen, J.E.

    1994-01-01

    The purpose of this report is to compile all the documentation which defines the criteria for Waste Encapsulation and Storage Facility (WESF) cesium capsules at the IOTECH facility and Applied Radiant Energy Corporation (ARECO) to be shipped as special form radioactive material in the Beneficial Uses Shipping System (BUSS) Cask. The capsules were originally approved as special form in 1975, but in 1988 the integrity of the capsules came into question. WHC developed the Pre-shipment Acceptance Test Criteria for capsules to meet in order to be shipped as special form material. The Department of Energy approved the criteria and directed WHC to ship the capsules at IOTECH and ARECO meeting this criteria to WHC as special form material

  1. Modulation of TRAIL resistance in colon carcinoma cells : Different contributions of DR4 and DR5

    NARCIS (Netherlands)

    van Geelen, Caroline M. M.; Pennarun, Bodvael; Le, Phuong T. K.; de Vries, Elisabeth G. E.; de Jong, Steven

    2011-01-01

    Background: rhTRAIL is a therapeutic agent, derived from the TRAIL cytokine, which induces apoptosis in cancer cells by activating the membrane death receptors 4 and 5 (DR4 and DR5). Here, we investigated each receptor's contribution to rhTRAIL sensitivity and rhTRAIL resistance. We assessed whether

  2. Clinical effect of Resina Draconis capsules on primary dysmenorrhoea

    African Journals Online (AJOL)

    Clinical effect of Resina Draconis capsules on primary dysmenorrhoea. Li Sun, Jia Wang. Abstract. Purpose: To examine the effectiveness of Resina Draconis capsules in the treatment of primary dysmenorrhoea. Methods: In total, 324 patients with primary dysmenorrhoea were randomly allocated to three groups based on ...

  3. Design Improvements of a Fuel Capsule for Re-irradiation Tests

    International Nuclear Information System (INIS)

    Kang, Young-Hwan; Choi, Myung-Hwan; Kim, Jong Kiun; Youm, Ki Un; Yoon, Ki Byeong; Kim, Bong Goo

    2006-01-01

    The development of an advanced reactor system such as the next generation nuclear plant and other generation IV systems require new fuels, claddings, and structural materials. To characterize the performance of these new materials, it is necessary for us to have leading-edge technology to satisfy the specific test requirements of the recent R and D activities such as the high-fluence- and high burnup- related tests. Thus, new capsule assembling technology and re-instrumentation technology has been developed to meet the demands for the high burnup test at HANARO since 2003. In 2003, a mockup of the capsule assembly machine was designed and fabricated. The performance test which started in 2004 was undertaken to determine and present the main performance characteristics of the capsule assembly machine (CAM) including the special tools. In 2005, a series of analyses using a finite element analysis program, ANSYS and full scale tests in air were performed to improve the design of the capsule's components for an effective utilization of the CAM. The handling tools were fully qualified through the performance tests in 2006. KAERI is now reviewing the water flow area in the top region of a fuel capsule main body for re-irradiation tests and optimizing the design of the central region area of a capsule to be joined with special bolts

  4. Analysis of DR4 haplotypes in insulin dependent diabetes (IDD)

    International Nuclear Information System (INIS)

    Monos, D.S.; Radka, S.F.; Zmijewski, C.M.; Kamoun, M.

    1986-01-01

    Population studies indicate that HLA-DR4 is implicated in the susceptibility of IDD. However, biochemical characterization of the serologically defined DR4 haplotype from normal individuals revealed five DR4 and three DQW3 molecular forms. Hence, in this study, they investigated the heterogeneity of the DR4 haplotype, using B-lymphoblastoid cell lines (B-LCL) generated from patients with IDD and seropositive for DR4. Class II molecules, metabolically labeled with 35 S-methionine, were immunoprecipitated with monoclonal antibodies specific for DR(L243), DQ(N297), DQW3(IVD12) or DR and DQ(SG465) and analyzed by two-dimensional polyacrylamide gel electrophoresis (2D-PAGE). The isoelectrofocusing (IEF) conditions employed in this study allow representation only of the DR4 haplotype from either DR3/4 or DR4/4 cell lines. The analysis of six different DR4 haplotypes from seven IDD patients, revealed the presence of two DR4 β and two DQW3 β chains. Three of the six DR4 β haplotypes analyzed shared the same DR4 β chain and three others shared a different one. Additionally five of the six haplotypes shared a different one. Additionally five of the six haplotypes shared the same DQW3 β chain and only one was carrying a different one. Different combinations of the two DR4 and two DQW3 β chains constitute three distinct patterns of DR4 haplotypes. These results suggest the prevalence of a DQW3 β chain in the small sample of IDD patients studied. Studies of a large number of patients should clarify whether IDD is associated with unique variants of DR4 or DQW3 β chains

  5. Adhesive capsulitis: review of imaging and treatment

    International Nuclear Information System (INIS)

    Harris, Guy; Bou-Haider, Pascal; Harris, Craig

    2013-01-01

    Adhesive capsulitis is one of the most common conditions affecting the shoulder; however, early clinical diagnosis can be challenging. Treatment is most effective when commenced prior to the onset of capsular thickening and contracture; consequently, the role of imaging is increasing. The aim of this review is to demonstrate the typical imaging appearances of adhesive capsulitis and to examine some of the evidence regarding each of these imaging modalities. An evaluation of the various management options available to the clinician is also presented.

  6. Validity, Reliability, and Inertia of Four Different Temperature Capsule Systems.

    Science.gov (United States)

    Bongers, Coen C W G; Daanen, Hein A M; Bogerd, Cornelis P; Hopman, Maria T E; Eijsvogels, Thijs M H

    2018-01-01

    Telemetric temperature capsule systems are wireless, relatively noninvasive, and easily applicable in field conditions and have therefore great advantages for monitoring core body temperature. However, the accuracy and responsiveness of available capsule systems have not been compared previously. Therefore, the aim of this study was to examine the validity, reliability, and inertia characteristics of four ingestible temperature capsule systems (i.e., CorTemp, e-Celsius, myTemp, and VitalSense). Ten temperature capsules were examined for each system in a temperature-controlled water bath during three trials. The water bath temperature gradually increased from 33°C to 44°C in trials 1 and 2 to assess the validity and reliability, and from 36°C to 42°C in trial 3 to assess the inertia characteristics of the temperature capsules. A systematic difference between capsule and water bath temperature was found for CorTemp (0.077°C ± 0.040°C), e-Celsius (-0.081°C ± 0.055°C), myTemp (-0.003°C ± 0.006°C), and VitalSense (-0.017°C ± 0.023°C; P 0.05). Comparable inertia characteristics were found for CorTemp (25 ± 4 s), e-Celsius (21 ± 13 s), and myTemp (19 ± 2 s), whereas the VitalSense system responded more slowly (39 ± 6 s) to changes in water bath temperature (P inertia were observed between capsule systems, an excellent validity, test-retest reliability, and inertia was found for each system between 36°C and 44°C after removal of outliers.

  7. Dr. von Braun and Dr. Stuhlinger With a Model of the Nuclear-Electric Vehicles

    Science.gov (United States)

    2004-01-01

    In this photo, taken at the Walt Disney Studios in California, Dr. Wernher von Braun and Dr. Ernst Stuhlinger are shown discussing the concepts of nuclear-electric spaceships designed to undertake the mission to the planet Mars. As a part of the Disney 'Tomorrowland' series on the exploration of space, the nuclear-electric vehicles were shown in the last three television films, entitled 'Mars and Beyond,' which first aired in December 1957.

  8. Strontium and cesium radionuclide leak detection alternatives in a capsule storage pool

    International Nuclear Information System (INIS)

    Larson, D.E.; Crawford, T.W.; Joyce, S.M.

    1981-08-01

    A study was performed to assess radionuclide leak-detection systems for use in locating a capsule leaking strontium-90 or cesium-137 into a water-filled pool. Each storage pool contains about 35,000 L of water and up to 715 capsules, each of which contains up to 150 kCi strontium-90 or 80 kCi cesium-137. Potential systems assessed included instrumental chemical analyses, radionuclide detection, visual examination, and other nondestructive nuclear-fuel examination techniques. Factors considered in the assessment include: cost, simplicity of maintenance and operation, technology availability, reliability, remote operation, sensitivity, and ability to locate an individual leaking capsule in its storage location. The study concluded that an adaption of the spent nuclear-fuel examination technique of wet sipping be considered for adaption. In the suggested approoch, samples would be taken continuously from pool water adjacent to the capsule(s) being examined for remote radiation detection. In-place capsule isolation and subsequent water sampling would confirm that a capsule was leaking radionuclides. Additional studies are needed before implementing this option. Two other techniques that show promise are ultrasonic testing and eddy-current testing

  9. State diagram for adhesion dynamics of deformable capsules under shear flow.

    Science.gov (United States)

    Luo, Zheng Yuan; Bai, Bo Feng

    2016-08-17

    Due to the significance of understanding the underlying mechanisms of cell adhesion in biological processes and cell capture in biomedical applications, we numerically investigate the adhesion dynamics of deformable capsules under shear flow by using a three-dimensional computational fluid dynamic model. This model is based on the coupling of the front tracking-finite element method for elastic mechanics of the capsule membrane and the adhesion kinetics simulation for adhesive interactions between capsules and functionalized surfaces. Using this model, three distinct adhesion dynamic states are predicted, such as detachment, rolling and firm-adhesion. Specifically, the effects of capsule deformability quantified by the capillary number on the transitions of these three dynamic states are investigated by developing an adhesion dynamic state diagram for the first time. At low capillary numbers (e.g. Ca state no longer appears, since capsules exhibit large deviation from the spherical shape.

  10. Capsule Development and Utilization for Material Irradiation Tests

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Bong Goo; Kang, Y H; Cho, M S [and others

    2007-06-15

    The essential technology for an irradiation test of materials and nuclear fuel has been successively developed and utilized to meet the user's requirements in Phase I(July 21, 1997 to March 31, 2000). It enables irradiation tests to be performed for a non-fissile material under a temperature control(300{+-}10 .deg. C) in a He gas environment, and most of the irradiation tests for the internal and external users are able to be conducted effectively. The basic technology was established to irradiate a nuclear fuel, and a creep capsule was also developed to measure the creep property of a material during an irradiation test in HANARO in Phase II(April 1, 2000 to March 31, 2003). The development of a specific purpose capsule, essential technology for a re-irradiation of a nuclear fuel, advanced technology for an irradiation of materials and a nuclear fuel were performed in Phase III(April 1, 2003 to February 28, 2007). Therefore, the technology for an irradiation test was established to support the irradiation of materials and a nuclear fuel which is required for the National Nuclear R and D Programs. In addition, an improvement of the existing capsule design and fabrication technology, and the development of an instrumented capsule for a nuclear fuel and a specific purpose will be able to satisfy the user's requirements. In order to support the irradiation test of materials and a nuclear fuel for developing the next generation nuclear system, it is also necessary to continuously improve the design and fabrication technology of the existing capsule and the irradiation technology.

  11. Anterior Lens Capsule and Iris Thicknesses in Pseudoexfoliation Syndrome.

    Science.gov (United States)

    Batur, Muhammed; Seven, Erbil; Tekin, Serek; Yasar, Tekin

    2017-11-01

    The aim of this study was to evaluate anatomic properties of the lens capsule and iris by anterior segment optical coherence tomography (AS-OCT) in patients with pseudoexfoliation (PEX). This prospective study included 62 eyes of 62 patients with PEX syndrome and 43 eyes of 43 age- and gender-matched controls. All subjects underwent full ophthalmologic examinations including AS-OCT. Pupillary diameter, midperipheral stromal iris thickness, central and temporal lens capsule thicknesses, and peripheral pseudoexfoliation material thickness on the anterior lens capsule surface were measured and recorded. Mean age was 66.8 ± 9.3 years in the PEX group and 65.5 ± 8.9 years in the control group (p = 0.44). The PEX group consisted of 62 patients: 38 men (61.3%) and 24 women (38.7%); the control group included 43 subjects: 25 men (58.1%) and 18 women (41.9%). Pupillary diameter after pharmacologic mydriasis was 21% smaller in the PEX group than controls. Mean midperipheral iris thickness was 36 ± 7.2 μm (7.8%) thinner in the PEX group than that of control group (p = 0.047). The central anterior capsule was a mean of 3.40 ± 0.51 μm (18%) thicker in the PEX group compared to the control group (p = 0.0001). The temporal anterior lens capsule was a mean of 0.17 ± 0.15 μm thicker in the PEX group compared to the control group (p = 0.81). With high-resolution OCT imaging, it has become possible to evaluate the anterior lens capsule without histologic examination and demonstrate that it is thicker than normal in PEX patients.

  12. Dr. Yu Wang, Director, Natural Science Division, National Science Council, Taiwan

    CERN Document Server

    Patrice Loïez

    2001-01-01

    Photo 01: L. to r.: Dr. Philippe Bloch, CERN CMS ECAL Deputy Project Manager, Dr. Yu Wang, Dr. Etiennette Auffray, CERN, responsible of the CERN ECAL Regional Centre. Photo 02: L. to r.: Dr. Yu Wang, Dr. Philippe Bloch, Dr. Apollo GO, National Central University, Taiwan, Dr. Etiennette Auffray.

  13. Dr. David Syz, State Secretary for Economic Affairs, Switzerland

    CERN Multimedia

    Patrice Loïez

    2003-01-01

    Photo 01: Dr. David Syz (left) with Professor Roger Cashmore, Research Director for Collider Programmes.Photo 02: Dr. David Syz signing the VIP visitors' book, with Prof. Roger Cashmore.Photo 03: Dr. David Syz signing the VIP visitors' book.Photo 04: Handshake between Dr. David Syz (left) and Prof. Roger Cashmore.

  14. An Interview with Dr. Walter Lear

    Directory of Open Access Journals (Sweden)

    The Editors

    2009-03-01

    Full Text Available In this issue of the English version of Social Medicine we are publishing the first of several pamphlets loaned to us by the US Health Activism History Collection. To introduce this collection we travelled to Philadelphia on June 18, 2008 to interview Dr. Walter J. Lear. Dr Lear, born in 1923, is the person responsible for the collection. In a wide-ranging interview in his home Dr. Lear discussed his personal background, the origins and purpose of the collection, the impact of the McCarthy period on the US health left, as well as his vision for the future.

  15. Characterisation of two AGATA asymmetric high purity germanium capsules

    International Nuclear Information System (INIS)

    Colosimo, S.J.; Moon, S.; Boston, A.J.; Boston, H.C.; Cresswell, J.R.; Harkness-Brennan, L.; Judson, D.S.; Lazarus, I.H.; Nolan, P.J.; Simpson, J.; Unsworth, C.

    2015-01-01

    The AGATA spectrometer is an array of highly segmented high purity germanium detectors. The spectrometer uses pulse shape analysis in order to track Compton scattered γ-rays to increase the efficiency of nuclear spectroscopy studies. The characterisation of two high purity germanium detector capsules for AGATA of the same A-type has been performed at the University of Liverpool. This work will examine the uniformity of performance of the two capsules, including a comparison of the resolution and efficiency as well as a study of charge collection. The performance of the capsules shows good agreement, which is essential for the efficient operation of the γ-ray tracking array

  16. Characterisation of two AGATA asymmetric high purity germanium capsules

    Energy Technology Data Exchange (ETDEWEB)

    Colosimo, S.J., E-mail: sjc@ns.ph.liv.ac.uk [Department of Physics, Oliver Lodge Laboratory, University of Liverpool, Liverpool L69 7ZE (United Kingdom); Moon, S.; Boston, A.J.; Boston, H.C.; Cresswell, J.R.; Harkness-Brennan, L.; Judson, D.S. [Department of Physics, Oliver Lodge Laboratory, University of Liverpool, Liverpool L69 7ZE (United Kingdom); Lazarus, I.H. [STFC Daresbury, Daresbury, Warrington WA4 4AD (United Kingdom); Nolan, P.J. [Department of Physics, Oliver Lodge Laboratory, University of Liverpool, Liverpool L69 7ZE (United Kingdom); Simpson, J. [STFC Daresbury, Daresbury, Warrington WA4 4AD (United Kingdom); Unsworth, C. [Department of Physics, Oliver Lodge Laboratory, University of Liverpool, Liverpool L69 7ZE (United Kingdom)

    2015-02-11

    The AGATA spectrometer is an array of highly segmented high purity germanium detectors. The spectrometer uses pulse shape analysis in order to track Compton scattered γ-rays to increase the efficiency of nuclear spectroscopy studies. The characterisation of two high purity germanium detector capsules for AGATA of the same A-type has been performed at the University of Liverpool. This work will examine the uniformity of performance of the two capsules, including a comparison of the resolution and efficiency as well as a study of charge collection. The performance of the capsules shows good agreement, which is essential for the efficient operation of the γ-ray tracking array.

  17. Analysis of mechanical property data obtained from nuclear pressure vessel surveillance capsules

    International Nuclear Information System (INIS)

    Perrin, J.S.

    1977-01-01

    A typical pressure vessel surveillance capsule examination program provides mechanical property data from tensile, Charpy V-notch impact, and, in some cases, fracture mechanics specimens. This data must be analyzed in conjunction with the unirradiated baseline mechanical property data to determine the effect of irradiation on the mechanical properties. In the case of Charpy impact specimens, for example, irradiation typically causes an increase in the transition temperature, and a decrease in the upper shelf energy level. The results of the Charpy impact and other mechanical specimen tests must be evaluated to determine if property changes are occurring in the manner expected when the reactor was put into service. The large amount of data obtained from surveillance capsule examinations in recent years enables one to make fairly good predictions. After the changes in the mechanical properties of specimens from a particular surveillance capsule have been experimentally determined and evaluated, they must be related to the reactor pressure vessel. This requires a knowledge of the neutron fluence of the surveillance capsule, and the ratio of the surveillance capsule fluence to the pressure vessel wall fluence. This ratio is frequently specified by the reactor manufacturer, or can be calculated from a knowledge of the geometry and materials of the reactor components inside the pressure vessel. A knowledge of the exact neutron fluence of the capsule specimens and the capsule to vessel wall neutron fluence ratio is of great importance, since inaccuracies in these numbers cause just as serious a problem as inaccuracies in the mechanical property determinations. A further area causing analysis difficulties is problems encountered in recent capsule programs relating to capsule design, construction, operation, and dismantling. (author)

  18. Capsule Performance Optimization in the National Ignition Campaign

    Energy Technology Data Exchange (ETDEWEB)

    Landen, O L; MacGowan, B J; Haan, S W; Edwards, J

    2009-10-13

    A capsule performance optimization campaign will be conducted at the National Ignition Facility to substantially increase the probability of ignition. The campaign will experimentally correct for residual uncertainties in the implosion and hohlraum physics used in our radiation-hydrodynamic computational models before proceeding to cryogenic-layered implosions and ignition attempts. The required tuning techniques using a variety of ignition capsule surrogates have been demonstrated at the Omega facility under scaled hohlraum and capsule conditions relevant to the ignition design and shown to meet the required sensitivity and accuracy. In addition, a roll-up of all expected random and systematic uncertainties in setting the key ignition laser and target parameters due to residual measurement, calibration, cross-coupling, surrogacy, and scale-up errors has been derived that meets the required budget.

  19. Capsule performance optimization in the national ignition campaign

    International Nuclear Information System (INIS)

    Landen, O L; MacGowan, B J; Haan, S W; Edwards, J

    2010-01-01

    A capsule performance optimization campaign will be conducted at the National Ignition Facility [1] to substantially increase the probability of ignition. The campaign will experimentally correct for residual uncertainties in the implosion and hohlraum physics used in our radiation-hydrodynamic computational models before proceeding to cryogenic-layered implosions and ignition attempts. The required tuning techniques using a variety of ignition capsule surrogates have been demonstrated at the Omega facility under scaled hohlraum and capsule conditions relevant to the ignition design and shown to meet the required sensitivity and accuracy. In addition, a roll-up of all expected random and systematic uncertainties in setting the key ignition laser and target parameters due to residual measurement, calibration, cross-coupling, surrogacy, and scale-up errors has been derived that meets the required budget.

  20. Capsule performance optimization in the national ignition campaign

    Science.gov (United States)

    Landen, O. L.; MacGowan, B. J.; Haan, S. W.; Edwards, J.

    2010-08-01

    A capsule performance optimization campaign will be conducted at the National Ignition Facility [1] to substantially increase the probability of ignition. The campaign will experimentally correct for residual uncertainties in the implosion and hohlraum physics used in our radiation-hydrodynamic computational models before proceeding to cryogenic-layered implosions and ignition attempts. The required tuning techniques using a variety of ignition capsule surrogates have been demonstrated at the Omega facility under scaled hohlraum and capsule conditions relevant to the ignition design and shown to meet the required sensitivity and accuracy. In addition, a roll-up of all expected random and systematic uncertainties in setting the key ignition laser and target parameters due to residual measurement, calibration, cross-coupling, surrogacy, and scale-up errors has been derived that meets the required budget.

  1. Research on garlic capsule and selenium-vitamin A, vitamin B, vitamin C applied in therapy of acute hepatocellular damage in a rat model

    OpenAIRE

    Jacob Kehinde Akintunde; Olakunle Enock Bolarin

    2015-01-01

    Objectives: To evaluate the toxicity of lisinopril in liver of male rats and its reversal effect of garlic capsule (GAR) and selenium-vitamin A, vitamin B, vitamin C (SACE). Methods: Thirty five adult male wistar rats were randomly assigned into 5 groups of 7 animals per group. Group I serves as the control, animals in Groups II, III, IV and V received 28 mg/kg body weight of lisinopril via oral route. Group III was co-treated with GAR at therapeutic dose of 250 mg/kg body weight per day. ...

  2. Integrity Assessment of HANARO Irradiation Capsule for Long-Term Irradiation Testing

    Energy Technology Data Exchange (ETDEWEB)

    Choo, Kee Nam; Cho, Man Soon; Yang, Sung Woo; Shin, Yoon Taek; Park, Seng Jae; Yang, Tae Ho; Jun, Byung Hyuk; Kim, Myong Seop [KAERI, Daejeon (Korea, Republic of); Hong, Sang Hyun [Chungnam University, Daejeon (Korea, Republic of)

    2016-05-15

    The capsule technology was basically developed for irradiation testing under a commercial reactor operation environment. Most irradiation testing using capsules has been performed at around 300 .deg. C within four reactor operation cycles (about 100 days equivalent to 1.5 dpa (displacement for atom)) at HANARO. Based on the accumulated experience as well as the sophisticated requirements of users, HANARO has recently been required to support national R and D projects requiring much higher neutron fluence. To scope the user requirements for higher neutron irradiation fluence, several efforts using an instrumented capsule have been applied at HANARO. In this paper, the applied stresses on the capsule are estimated because the capsule was suspected to be susceptible to fatigue failure during irradiation testing. In addition, the on-going design improvements of the irradiation capsule for higher neutron irradiation fluence at HANARO are described. The applied stresses on the rod tip were analyzed using the ANSYS program. The applied stresses on the rod tip can be classified into stresses by the designed bottom spring, by the upward flowing coolant, by the capsule vibration, and by the welding residual stress. The maximal stresses due to the first three factors were estimated as 5.4 MPa, 132.9 MPa, and 161 MPa, respectively. These stresses do not exceed the known fatigue strength of stainless steels (∼300 MPa). Residual stress by welding is another possible stress and it is known to occur at up to about 300 MPa.

  3. WESF cesium capsule behavior at high temperature or during thermal cycling

    International Nuclear Information System (INIS)

    Tingey, G.L.; Gray, W.J.; Shippell, R.J.; Katayama, Y.B.

    1985-06-01

    Double-walled stainless steel (SS) capsules prepared for storage of radioactive 137 Cs from defense waste are now being considered for use as sources for commercial irradiation. Cesium was recovered at B-plant from the high-level radioactive waste generated during processing of defense nuclear fuel. It was then purified, converted to the chloride form, and encapsulated at the Hanford Waste Encapsulation and Storage Facility (WESF). The molten cesium chloride salt was encapsulated by pouring it into the inner of two concentric SS cylinders. Each cylinder was fitted with a SS end cap that was welded in place by inert gas-tungsten arc welding. The capsule configuration and dimensions are shown in Figure 1. In a recent review of the safety of these capsules, Tingey, Wheelwright, and Lytle (1984) indicated that experimental studies were continuing to produce long-term corrosion data, to reaffirm capsule integrity during a 90-min fire where capsule temperatures reached 800 0 C, to monitor mechanical properties as a function of time, and to assess the effects of thermal cycling due to periodic transfer of the capsules from a water storage pool to the air environment of an irradiator facility. This report covers results from tests that simulated the effects of the 90-min fire and from thermal cycling actual WESF cesium capsules for 3845 cycles over a period of six months. 11 refs., 39 figs., 9 tabs

  4. HLA-DR expression and disease activity in ulcerative colitis

    DEFF Research Database (Denmark)

    Poulsen, L O; Elling, P; Sørensen, Flemming Brandt

    1986-01-01

    In 12 patients with active ulcerative colitis (UC) the rectal epithelial cells were analyzed for HLA-DR antigens by an immunohistochemical technique. The clinical, rectoscopic, and histologic stages were also determined. The investigations were carried out at the beginning of the study and 2 weeks...... and 3 months later. The rectal epithelial cells were HLA-DR-positive in all patients at the first two examinations. After 3 months five patients had changed to an HLA-DR-negative stage, whereas the other seven patients remained HLA-DR-positive. Closer analyses showed that expression/nonexpression of HLA-DR...... antigens on rectal epithelial cells of patients with UC could not be predicted from the clinical, rectoscopic, or histologic findings. HLA-DR expression is normally restricted to immunocompetent cells. The presence of HLA-DR antigens on epithelial cells may be a consequence of immunological reactions...

  5. HLA Dr beta 1 alleles in Pakistani patients with rheumatoid arthritis

    International Nuclear Information System (INIS)

    Naqi, N.; Ahmed, T.A.; Bashir, M.M.

    2011-01-01

    Objective: To determine frequencies of HLA DR beta 1 alleles in rheumatoid arthritis in Pakistani patients. Study Design: Cross sectional / analytical study. Place and Duration of Study: Department of Immunology, Armed Forces Institute of Pathology, Rawalpindi in collaboration with Rheumatology departments of Military Hospital, Rawalpindi and Fauji Foundation Hospital, Rawalpindi, from January 2009 to January 2010. Methodology: HLA DR beta 1 genotyping of one hundred Pakistani patients, diagnosed as having RA as per American College of Rheumatology revised criteria 1987, was done. HLA DR beta 1 genotyping was carried out at allele group level (DR beta 1*01-DR beta 1*16) by sequence specific primers in RA patients. Comparison of HLA DR beta 1 allele frequencies between patients and control groups was made using Pearson's chi-square test to find possible association of HLA DR?1 alleles with RA in Pakistani rheumatoid patients. Results: HLA DR beta 1*04 was expressed with significantly increased frequency in patients with rheumatoid arthritis (p <0.05). HLA DR?1*11 was expressed statistically significantly more in control group as compared to rheumatoid patients indicating a possible protective effect. There was no statistically significant difference observed in frequencies of HLA DR beta 1 allele *01, DR beta 1 allele *03, DR beta 1 allele *07, DR beta 1 allele *08, DR beta 1 allele *09, DR beta 1 allele *10, DR beta 1 allele *12, DR beta 1 allele *13, DR beta 1 allele *14, DR?1 allele *15 and DR beta 1 allele *16 between patients and control groups. Conclusion: The identification of susceptible HLA DR beta 1 alleles in Pakistani RA patients may help physicians to make early decisions regarding initiation of early intensive therapy with disease modifying anti rheumatic medicines and biological agents decreasing disability in RA patients. (author)

  6. Sub-Scale Re-entry Capsule Drop via High Altitude Balloons

    Data.gov (United States)

    National Aeronautics and Space Administration — The project objective is to develop and test a sub-scale version of the Maraia Entry Capsule on a high altitude balloon. The capsule is released at 100,000 ft. The...

  7. Perbandingan Pemberian Ondansetron 8 mg dengan Tramadol 1 mg/ kgBB Intravena untuk Mencegah Menggigil Pascaanestesi Umum pada Operasi Mastektomi Radikal atau Modifikasi

    Directory of Open Access Journals (Sweden)

    Mirza Oktavian

    2014-04-01

    Full Text Available ost anesthetic shivering is a common complication of general anesthesia and preventable with several types of drugs. The aim of this study was to compare the efficacy of intravenous 8mg ondansetron versus tramadol 1 mg/kgBW in preventing post anesthetic shivering after general anesthesia. The research is a prospective, randomized double-blind controlled study involving 38 female patients aged 30–65 years at Dr. Hasan Sadikin Hospital Bandung period March–April 2012, American Society of Anesthesiologist (ASA physical status I–II, who underwent radical or modified mastectomy. Subjects were randomly divided into two groups. One group was given ondansetron 8 mg and the other group was given tramadol 1 mg/kgBW before surgical wound closure. Research results showed that incidence of post anesthetic shivering was less on tramadol group (15.8% compared to ondansetron (52.6% group, which is statistically significant (p<0.05. In conclusion, administration of tramadol 1 mg/kgBW intravenously is more effective in preventing post anesthetic shivering in radical or modified mastectomy.

  8. FOREWORD: Dr Trevor J Hicks Dr Trevor J Hicks

    Science.gov (United States)

    Goossens, Darren

    2009-03-01

    This issue of Journal of Physics: Condensed Matter has been assembled to recognize the valuable contribution of Dr Trevor J Hicks to the field of neutron scattering and magnetism. Trevor began his study of magnetism as a PhD student at Monash University in Melbourne in the early 1960s, working with Professor Jack Smith. From the very beginning magnetism in alloys, and disordered systems in general, became a key aspect of his career. After a postdoctoral position at Harwell working with Dr Graeme Low Trevor returned to Australia and took up a position with Monash. He soon became a key figure in developing the capability for neutron scattering using the HIFAR reactor at the Australian Atomic Energy Commission, now the Australian Nuclear Science and Technology Organisation, ANSTO. The instrumentation was always developed to further his studies of magnetism. The development of polarization analysis measurements of diffuse magnetic scattering, first using iron filters and then his own design of supermirror benders for beam polarization, took place through the 1970s, 1980s and into the 1990s. Throughout this time, Trevor mentored a series of PhD students and postdoctoral fellows, many of whom have contributed to this issue (and, indeed, guest edited it). As befits a scientist and university academic for whom teaching has always been important, Trevor has not only created a strong body of significant research, he has also made a major contribution to preparing several generations of neutron scattering scientists, and this issue reflects that. When I approached Journal of Physics: Condensed Matter with a proposal for an issue in honour of Trevor, the response was immediate and positive. It is with great pleasure that I present the result of that proposal. The great diversity of the content, all centred on neutron scattering and magnetism, reflects the breadth of Trevor's own career and of the scientists with whom he has interacted. Finally, I would like to make some

  9. Comparaison du Srōš Drōn avec le Drōn Yašt

    OpenAIRE

    Redard, Céline

    2015-01-01

    This paper draws a parallel between two texts having the same textual base: The Srōš Drōn, derived from the Long Liturgy and the Drōn Yašt, belonging to the short liturgies. The goal is to establish the similarities and the discrepancies between these two texts. Peer reviewed

  10. Development of glia and blood vessels in the internal capsule of rats.

    Science.gov (United States)

    Earle, K L; Mitrofanis, J

    1998-02-01

    We have explored two aspects of internal capsule development that have not been described previously, namely, the development of glia and of blood vessels. To these ends, we used antibodies to glial fibrillary acidic protein (GFAP) and to vimentin (to identify astrocytes and to radial glia) and Griffonia simplicifolia (lectin; to identify microglia and blood vessels). Further, we made intracardiac injections of Evans Blue to examine the permeability of this dye in the vessels of the internal capsule during neonatal development. Our results show that large numbers of radial glia, astrocytes and microglia are not labelled with these markers in the white matter of the internal capsule until about birth; very few are labelled earlier, during the critical stages of corticofugal and corticopetal axonal ingrowth (E15-E20). The large glial labelling in the internal capsule at birth is accompanied by a dense vascular innervation of the capsule; as with the glia, very few labelled patent vessels are seen earlier. After intracardiac injections of Evans Blue, we find that the blood vessels of the internal capsule are not particularly permeable to Evans Blue. At each age examined (P0, P5, P15), blood vessels are outlined very clearly and there is no diffuse haze of fluorescence within the extracellular space, which is indicative of a leaky vessel. There are three striking differences between the glial environment of the internal capsule and that of the adjacent thalamus. First, the internal capsule is never rich with radial glial fibres (vimentin- and GFAP-immunoreactive) during development (except at P0), whereas the thalamus has many radial fibres from very early development (E15-E17). Second, astrocytes (vimentin- and GFAP-immunoreactive) first become apparent in the internal capsule (E20-P0) well before they do in the thalamus (P15). Third, the internal capsule houses a large transient population of amoeboid microglia (P0-P22), whereas the thalamus does not; only ramified

  11. Association of differentiated thyroid carcinoma with HLA-DR7

    International Nuclear Information System (INIS)

    Sridama, V.; Hara, Y.; Fauchet, R.; DeGroot, L.J.

    1985-01-01

    Seventy-four American white thyroid cancer patients were typed for HLA-A, B, and DR antigens. A significant increase in HLA-DR7 was found in the nonradiation-associated thyroid cancer patients (42.5%, 20/47 cases), compared to 22.8% of 979 normal controls. The association is stronger in the follicular and mixed papillary-follicular subgroup (52.0%, 13/25 cases, P corrected less than 0.01). The occurrence of various malignancies in family members was found in 57.9% of HLA-DR7 positive patients, versus 20% of HLA-DR7 negative patients, in a retrospective record review. Although the frequency of HLA-DR7 was not increased in the radiation-associated thyroid cancer patients (22.2%, 6/27 cases), the interval from the irradiation date to the onset date of thyroid cancer was shorter in HLA-DR7 positive cases (17.3 +/- 6.2 years) than in HLA-DR7 negative patients (29.4 +/- 11.5 years). This data suggest that HLA-DR7 is associated with and may influence development of thyroid cancer

  12. A legged anchoring mechanism for capsule endoscopes using micropatterned adhesives.

    Science.gov (United States)

    Glass, Paul; Cheung, Eugene; Sitti, Metin

    2008-12-01

    This paper presents a new concept for an anchoring mechanism to enhance existing capsule endoscopes. The mechanism consists of three actuated legs with compliant feet lined with micropillar adhesives to be pressed into the intestine wall to anchor the device at a fixed location. These adhesive systems are inspired by gecko and beetle foot hairs. Single-leg and full capsule mathematical models of the forces generated by the legs are analyzed to understand capsule performance. Empirical friction models for the interaction of the adhesives with an intestinal substrate were experimentally determined in vitro using dry and oil-coated elastomer micropillar arrays with 140 microm pillar diameter, 105 microm spacing between pillars, and an aspect ratio of 1:1 on fresh porcine small intestine specimens. Capsule prototypes were also tested in a simulated intestine environment and compared with predicted peristaltic loads to assess the viability of the proposed design. The experimental results showed that a deployed 10 gr capsule robot can withstand axial peristaltic loads and anchor reliably when actuation forces are greater than 0.27 N using dry micropillars. Required actuation forces may be reduced significantly by using micropillars coated with a thin silicone oil layer.

  13. A disposable and multifunctional capsule for easy operation of microfluidic elastomer systems

    International Nuclear Information System (INIS)

    Thorslund, Sara; Läräng, Thomas; Kreuger, Johan; Nguyen, Hugo; Barkefors, Irmeli

    2011-01-01

    The global lab-on-chip and microfluidic markets for cell-based assays have been predicted to grow considerably, as novel microfluidic systems enable cell biologists to perform in vitro experiments at an unprecedented level of experimental control. Nevertheless, microfluidic assays must, in order to compete with conventional assays, be made available at easily affordable costs, and in addition be made simple to operate for users having no previous experience with microfluidics. We have to this end developed a multifunctional microfluidic capsule that can be mass-produced at low cost in thermoplastic material. The capsule enables straightforward operation of elastomer inserts of optional design, here exemplified with insert designs for molecular gradient formation in microfluidic cell culture systems. The integrated macro–micro interface of the capsule ensures reliable connection of the elastomer fluidic structures to an external perfusion system. A separate compartment in the capsule filled with superabsorbent material is used for internal waste absorption. The capsule assembly process is made easy by integrated snap-fits, and samples within the closed capsule can be analyzed using both inverted and upright microscopes. Taken together, the capsule concept presented here could help accelerate the use of microfluidic-based biological assays in the life science sector. (technical note)

  14. Dr. Martin Luther King, Jr. as Spiritual Leader

    Directory of Open Access Journals (Sweden)

    Andrea Pierce

    2013-09-01

    Full Text Available The purpose of this paper is to explore Dr. Martin Luther King Jr.’s spiritual leadership through his “I Have a Dream” speech. The paper explores the three characteristics of spiritual leadership as posed by Fry’s (2003 spiritual leadership theory: vision, hope/faith and altruistic love. The research draws upon these characteristics through qualitative content analysis of Dr. Martin Luther King Jr.’s “I Have a Dream” speech to illustrate Dr. King’s leadership as that of a spiritual leader. The research advances the spiritual leadership theory by establishing Dr. Martin Luther King Jr. as a spiritual leader. Through the illustration of Dr. King’s spiritual leadership, the characteristics of a spiritual leader are given tangible understanding.

  15. The DR-2 project

    DEFF Research Database (Denmark)

    Ølgaard, Povl Lebeck

    2003-01-01

    state of the reactor and to determine, which radionuclides remain where in the reactor in what amounts. The first part of the reactor to be investigated was the reactor tank. The lids at the reactor top wereremoved, air samples taken and smear test made in the tank. Then the control rods, the magnet....... At the start of the project the activity in DR-2 was about 45-50 GBq. Now it is about 5-10 GBq. Based on the results of the DR-2 project it is believed that the reactor can readily bedismantled and decommissioned....

  16. Effect of preparation conditions on properties and permeability of chitosan-sodium hexametaphosphate capsules.

    Science.gov (United States)

    Angelova, N; Hunkeler, D

    2001-01-01

    Capsules were obtained by interpolymer complexation between chitosan (polycation) and sodium hexametaphosphate (SMP, oligoanion). The effect of the preparation conditions on the capsule characteristics was evaluated. Specifically, the influence of variables such as pH, ionic strength, reagent concentration, and additives on the capsule permeability properties was investigated using dextran as a model permeant. The capsule membrane permeability was found to increase by decreasing the chitosan/SMP ratio as well as adding mannitol to the oligoanion recipient bath. Increasing the ionic strength or the pH of the initial chitosan solution was also found to enhance the membrane permeability, moving the membrane exclusion limit to higher values. Generally, the capsules prepared tinder all tested conditions had a relatively low permeability which rarely exceeded a molecular cut-off of 40 kD based on dextran standards. Furthermore, the diffusion rate showed a strong temporal dependence, indicating that the capsules prepared under various conditions exhibit different apparent pore size densities on the surface. The results indicated that, in order to obtain the desired capsule mass-transfer properties, the preparation conditions should be carefully considered and adjusted. Adding a polyol as well as low salt amount (less than 0.15%) is preferable as a means of modulating the diffusion characteristics, without disturbing the capsule mechanical stability.

  17. Tribute to Dr Jacques Rogge

    DEFF Research Database (Denmark)

    Bourgois, Jan G; Dumortier, Jasmien; Callewaert, Margot

    2017-01-01

    'A tribute to Dr J. Rogge' aims to systematically review muscle activity and muscle fatigue during sustained submaximal quasi-isometric knee extension exercise (hiking) related to Olympic dinghy sailing as a tribute to Dr Rogge's merits in the world of sports. Dr Jacques Rogge is not only...... of invasive needle electromyography (EMG) during a specific sailing technique (hiking) on a self-constructed sailing ergometer. Hiking is a bilateral and multi-joint submaximal quasi-isometric movement which dinghy sailors use to optimize boat speed and to prevent the boat from capsizing. Large stresses...... are generated in the anterior muscles that cross the knee and hip joint, mainly employing the quadriceps at an intensity of 30-40% maximal voluntary contraction (MVC), sometimes exceeding 100% MVC. Better sailing level is partially determined by a lower rate of neuromuscular fatigue during hiking and for ≈60...

  18. SATCAP: a program for thermal-hydraulic design of saturated temperature capsule

    International Nuclear Information System (INIS)

    Harayama, Yasuo; Niimi, Motoji; Someya, Hiroyuki; Kobayashi, Toshiki.

    1988-02-01

    For material irradiation tests at JMTR, user's technical requirements are gradually becoming more rigid, permitting only a small temperature deviation from the desired during irradiation of test materials. As specimen temperature control equipment, several conception were proposed and some of them were translated into actual machines with the capsule having electrical seath heaters in it. This system is highly reliable unless the integrity of the heaters is threatened. However, in a test with the object of achieving a high exposure of specimen to neutrons, the break of a heater or deterioration of a heater caused by irradiation lowers the reliability of the system. To cope with this drawback, as a part of the irradiation technique improvement program, ''Satulated Temperature Capsule'' has been developing. This type capsule, in which the water suplied is boiled, bases on the conception of keeping the coolant at the saturated temperature facilitates the temperature control. Though there are various types of capsules employed at JMTR, the experience of the capsule into which the coolant is injected lacks. In designing, thermal performances have to fully understood. Therefore, a program was compiled to evaluate the thermal behavior in the capsule. The present report describes the calculation procedure and guides of input and output for the program. (author)

  19. Capsule Development and Utilization for Material Irradiation Tests

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Bong Goo; Kang, Y. H.; Cho, M. S. (and others)

    2007-06-15

    The essential technology for an irradiation test of materials and nuclear fuel has been successively developed and utilized to meet the user's requirements in Phase I(July 21, 1997 to March 31, 2000). It enables irradiation tests to be performed for a non-fissile material under a temperature control(300{+-}10 .deg. C) in a He gas environment, and most of the irradiation tests for the internal and external users are able to be conducted effectively. The basic technology was established to irradiate a nuclear fuel, and a creep capsule was also developed to measure the creep property of a material during an irradiation test in HANARO in Phase II(April 1, 2000 to March 31, 2003). The development of a specific purpose capsule, essential technology for a re-irradiation of a nuclear fuel, advanced technology for an irradiation of materials and a nuclear fuel were performed in Phase III(April 1, 2003 to February 28, 2007). Therefore, the technology for an irradiation test was established to support the irradiation of materials and a nuclear fuel which is required for the National Nuclear R and D Programs. In addition, an improvement of the existing capsule design and fabrication technology, and the development of an instrumented capsule for a nuclear fuel and a specific purpose will be able to satisfy the user's requirements. In order to support the irradiation test of materials and a nuclear fuel for developing the next generation nuclear system, it is also necessary to continuously improve the design and fabrication technology of the existing capsule and the irradiation technology.

  20. Remote-welding technique for assembling in-pile IASCC capsule in hot cell

    International Nuclear Information System (INIS)

    Kawamata, Kazuo; Ishii, Toshimitsu; Kanazawa, Yoshiharu; Iwamatsu, Shigemi; Ohmi, Masao; Shimizu, Michio; Matsui, Yoshinori; Saito, Jun-ichi; Ugachi, Hirokazu; Kaji, Yoshiyuki; Tsukada, Takashi

    2006-01-01

    In order to investigate behavior of the irradiation assisted stress corrosion cracking (IASCC) caused by the simultaneous effects of neutron irradiation and high temperature water environment in such a light water reactor (LWR), it is necessary to perform crack growth tests in an in-pile IASCC capsule irradiated in the Japan Materials Testing Reactor (JMTR). The development of the remote-welding technique is essential for remotely assembling the in-pile IASCC capsule installing the pre-irradiated CT specimens. This report describes a new remote-welding machine developed for assembling the in-pile IASCC capsule. The remote-welding technique that the capsule tube is rotated light under the fixed torch was applied to the machine for the welding of thick and large-diameter tubes. The assembly work of four in-pile IASCC capsules having pre-irradiated CT specimens in the hot cell was succeeded for performing the crack growth test under the neutron irradiation in JMTR. The irradiation test of two capsules has been already finished in JMTR without problems. (author)

  1. Development of target capsules for muon catalyzed fusion experiments

    International Nuclear Information System (INIS)

    Watts, K.D.; Jones, S.E.; Caffrey, A.J.

    1983-01-01

    A series of Muon Catalyzed Fusion experiments has been conducted at the Los Alamos Meson Physics Facility to determine how many fusion reactions one muon would catalyze under various temperature, pressure, contamination, and tritium concentration conditions. Target capsules to contain deuterium and tritium at elevated temperatures and pressures were engineered for a maximum temperature of 540 K (512 0 F) and a maximum pressure of 103 MPa (15,000 psig). Experimental data collected with these capsules indicated that the number of fusion reactions per muon continued to increase with temperature up to the 540-K design limit. Theory had indicated that the reaction rate should peak at approximately 540 K, but this was not confirmed during the experiments. A second generation of capsules which have a maximum design temperature of 800 K (980 0 F) and a maximum design pressure of 103 MPa (15,000 psig) has now been engineered. These new capsules will be used to further study the muon catalysis rate versus deuterium-tritium mixture temperature

  2. Human immune responsiveness to Lolium perenne pollen allergen Lol p III (rye III) is associated with HLA-DR3 and DR5.

    Science.gov (United States)

    Ansari, A A; Freidhoff, L R; Meyers, D A; Bias, W B; Marsh, D G

    1989-05-01

    A well-characterized allergen of Lolium perenne (perennial rye grass) pollen, Lol p III, has been used as a model antigen to study the genetic control of the human immune response. Associations between HLA type and IgE or IgG antibody (Ab) responsiveness to Lol p III were studied in two groups of skin-test-positive Caucasoid adults (N = 135 and 67). We found by nonparametric and parametric analyses that immune responsiveness to Lol p III was significantly associated with HLA-DR3 and DR5. No association was found between any DQ type and immune responsiveness to Lol p III. Geometric mean IgE or IgG Ab levels to Lol p III were not different between B8+, DR3+ subjects and B8-, DR3+ subjects, showing that HLA-B8 had no influence on the association. Lol p III IgG Ab data obtained on subjects after grass antigen immunotherapy showed that 100% of DR3 subjects and 100% of DR5 subjects were Ab+. A comparison of all the available protein sequences of DRB gene products showed that the first hypervariable region of DR3 and DR5 (and DRw6), and no other region, contains the sequence Glu9-Tyr-Ser-Thr-Ser13. Our observations are consistent with the possibility that immune responsiveness to the allergen Lol p III is associated with this amino acid sequence in the first hypervariable region of the DR beta 1 polypeptide chain.

  3. Development and Testing of a Magnetically Actuated Capsule Endoscopy for Obesity Treatment.

    Directory of Open Access Journals (Sweden)

    Thanh Nho Do

    Full Text Available Intra-gastric balloons (IGB have become an efficient and less invasive method for obesity treatment. The use of traditional IGBs require complex insertion tools and flexible endoscopes to place and remove the balloon inside the patient's stomach, which may cause discomfort and complications to the patient. This paper introduces a new ingestible weight-loss capsule with a magnetically remote-controlled inflatable and deflatable balloon. To inflate the balloon, biocompatible effervescent chemicals are used. As the source of the actuation is provided via external magnetic fields, the magnetic capsule size can be significantly reduced compared to current weight-loss capsules in the literature. In addition, there are no limitations on the power supply. To lose weight, the obese subject needs only to swallow the magnetic capsule with a glass of water. Once the magnetic capsule has reached the patient's stomach, the balloon will be wirelessly inflated to occupy gastric space and give the feeling of satiety. The balloon can be wirelessly deflated at any time to allow the magnetic capsule to travel down the intestine and exit the body via normal peristalsis. The optimal ratio between the acid and base to provide the desired gas volume is experimentally evaluated and presented. A prototype capsule (9.6mm x 27mm is developed and experimentally validated in ex-vivo experiments. The unique ease of delivery and expulsion of the proposed magnetic capsule is slated to make this development a good treatment option for people seeking to lose excess weight.

  4. Acid Inhibitory Effect of a Combination of Omeprazole and Sodium Bicarbonate (CDFR0209) Compared With Delayed-Release Omeprazole 40 mg Alone in Healthy Adult Male Subjects.

    Science.gov (United States)

    Kim, Kyu-Nam; Yang, Sung-Won; Kim, Hyunil; Kwak, Seong Shin; Kim, Young-Sang; Cho, Doo-Yeoun

    2018-01-01

    CDFR0209, a combination of an immediate-release formulation of omeprazole 40 mg and sodium bicarbonate 1100 mg, has been developed to treat acid-related disorders. We compared the acid inhibitory effects of CDFR0209 and delayed-release omeprazole (omeprazole-DR, Losec 40 mg) after repeated dosing in Helicobacter pylori-negative healthy adult male subjects. In this 2-period crossover study, 30 subjects were randomized to CDFR0209 or omeprazole-DR daily for 7 days. An ambulatory continuous 24-hour intragastric pH recording was performed at baseline and on days 1 and 7 of each administration period. Integrated gastric acidity was calculated from time-weighted average hydrogen ion concentrations at each hour of the 24-hour record. An analysis of variance model was used to test the pharmacodynamic equivalence of CDFR0209 and omeprazole-DR, using the natural logarithmic transformation of the percent decrease from baseline in integrated gastric acidity for the 24-hour interval after the seventh dose of each omeprazole formulation. The geometric least-squares mean ratios (CDFR0209/omeprazole-DR) of the percent decrease from baseline in integrated gastric acidity was 0.98 (90%CI, 0.93-1.07). Both CDFR0209 and omeprazole-DR are equally effective in decreasing integrated gastric acidity at steady state. © 2017, The American College of Clinical Pharmacology.

  5. Temporary presence of myofibroblasts in human elbow capsule after trauma

    NARCIS (Netherlands)

    Doornberg, Job N.; Bosse, Tjalling; Cohen, Mark S.; Jupiter, Jesse B.; Ring, David; Kloen, Peter

    2014-01-01

    Elbow stiffness is a common complication after elbow trauma. The elbow capsule is often thickened, fibrotic, and contracted at the time of surgical release. The limited studies available suggest that the capsule is contracted because of fibroblast-to-myofibroblast differentiation. We hypothesize

  6. Non-small-bowel abnormalities identified during small bowel capsule endoscopy

    NARCIS (Netherlands)

    Hoedemakers, Reinier; Westerhof, Jessie; Weersma, Rinse K.; Koornstra, Jan J.

    2014-01-01

    AIM: To investigate the incidence of non-small-bowel abnormalities in patients referred for small bowel capsule endoscopy, this single center study was performed. METHODS: Small bowel capsule endoscopy is an accepted technique to investigate obscure gastrointestinal bleeding. This is defined as

  7. Transport of solid commodities via freight pipeline: freight pipeline technology. Volume II. First year final report. [Slurry, pneumatic, pneumo-capsule, and hydro-capsule

    Energy Technology Data Exchange (ETDEWEB)

    Zandi, I.; Gimm, K.K.

    1976-07-01

    In order to determine the feasibility of pipeline as an intercity freight transportation mode, it was necessary to examine its technological feasibility and reliability. This report describes the technology of the major generic freight pipelines in terms of both historical and current trends and operations. Additionally, it presents a state-of-the-art review of calculating energy requirements of various generic freight pipelines. It was concluded that slurry and pneumatic pipelines are technologically feasible and reliable. There are many commercial installations of both types operating around the world. Based on European experience with pneumo-capsule pipelines for mail delivery and Russian gravel- and sand-transport installations, it appears that a pneumo-capsule pipeline is a technologically feasible and operationally reliable mode for transport of solids. Since no commercial pneumo-capsule pipeline installations yet exist in the U.S., it seems desirable that a service demonstration of the advantages and feasibility of this mode of transport be undertaken to attract the shippers' confidence. Hydro-capsule pipelines are technologically feasible, but its reliability within a commercial environment remains to be tested.

  8. Foot-pulse radiation drive necessary for ICF ignition capsule demonstrated on Z generator

    International Nuclear Information System (INIS)

    Sanford, T.W.L.; Olson, R.E.; Chandler, G.A.

    1999-01-01

    Implosion and ignition of an indirectly-driven ICF capsule operating near a Fermi-degenerate isentrope requires initial Planckian-radiation-drive temperatures of 70-to-90 eV to be present for a duration of 10-to-15 ns prior to the main drive pulse. Such capsules are being designed for high pulsed-power generators. This foot-pulse drive capability has been recently demonstrated in a NIF-sized (φ = 6-mm 1 = 7-mm), gold hohlraum, using a one-sided static-wall hohlraum geometry on the Z generator. The general arrangement utilized nested tungsten-wire arrays of radii (mass) 20 mm (2 mg) and 10 mm (1 mg) that had an axial length of approximately 10 mm. The arrays were driven by a peak current of approximately 21 MA and were made to implode on a 2-microm-thick Cu annulus (mass = 4.5 mg), which had a radius of 4 mm and was filled with a low-density CH foam, all centered about the z-axis. The gold hohlraum was mounted on axis and above the Cu/foam target. A 2.9-mm-radius axial hole between the top of the target and hohlraum permitted the x-rays generated from the implosion to enter the hohlraum. The radiation within the hohlraum was monitored by viewing the hohlraum through a 3-mm diameter hole on the lateral side of the hohlraum with a suite of diagnostics.The radiation entering the hohlraum was estimated by an additional suite of on-axis diagnostics, in a limited number of separate shots, when the hohlraum was not present. Additionally, the radiation generated outside the Cu annulus was monitored, for all shots, through a 3-mm diameter aperture located on the outside of the current return can. In the full paper, the characteristics of the radiation measured from these diagnostic sets, including the Planckian temperature of the hohlraum and radiation images, will be discussed as a function of the incident wire-array geometry (single vs nested array and array mass), target length (10, or 20 mm), annulus material (Cu, Au, or nothing), and CH-foam-fill density (10, 6, 2

  9. Abundance and co-occurrence of extracellular capsules increase environmental breadth: Implications for the emergence of pathogens.

    Science.gov (United States)

    Rendueles, Olaya; Garcia-Garcerà, Marc; Néron, Bertrand; Touchon, Marie; Rocha, Eduardo P C

    2017-07-01

    Extracellular capsules constitute the outermost layer of many bacteria, are major virulence factors, and affect antimicrobial therapies. They have been used as epidemiological markers and recently became vaccination targets. Despite the efforts to biochemically serotype capsules in a few model pathogens, little is known of their taxonomic and environmental distribution. We developed, validated, and made available a computational tool, CapsuleFinder, to identify capsules in genomes. The analysis of over 2500 prokaryotic genomes, accessible in a database, revealed that ca. 50% of them-including Archaea-encode a capsule. The Wzx/Wzy-dependent capsular group was by far the most abundant. Surprisingly, a fifth of the genomes encode more than one capsule system-often from different groups-and their non-random co-occurrence suggests the existence of negative and positive epistatic interactions. To understand the role of multiple capsules, we queried more than 6700 metagenomes for the presence of species encoding capsules and showed that their distribution varied between environmental categories and, within the human microbiome, between body locations. Species encoding capsules, and especially those encoding multiple capsules, had larger environmental breadths than the other species. Accordingly, capsules were more frequent in environmental bacteria than in pathogens and, within the latter, they were more frequent among facultative pathogens. Nevertheless, capsules were frequent in clinical samples, and were usually associated with fast-growing bacteria with high infectious doses. Our results suggest that capsules increase the environmental range of bacteria and make them more resilient to environmental perturbations. Capsules might allow opportunistic pathogens to profit from empty ecological niches or environmental perturbations, such as those resulting from antibiotic therapy, to colonize the host. Capsule-associated virulence might thus be a by-product of environmental

  10. Abundance and co-occurrence of extracellular capsules increase environmental breadth: Implications for the emergence of pathogens.

    Directory of Open Access Journals (Sweden)

    Olaya Rendueles

    2017-07-01

    Full Text Available Extracellular capsules constitute the outermost layer of many bacteria, are major virulence factors, and affect antimicrobial therapies. They have been used as epidemiological markers and recently became vaccination targets. Despite the efforts to biochemically serotype capsules in a few model pathogens, little is known of their taxonomic and environmental distribution. We developed, validated, and made available a computational tool, CapsuleFinder, to identify capsules in genomes. The analysis of over 2500 prokaryotic genomes, accessible in a database, revealed that ca. 50% of them-including Archaea-encode a capsule. The Wzx/Wzy-dependent capsular group was by far the most abundant. Surprisingly, a fifth of the genomes encode more than one capsule system-often from different groups-and their non-random co-occurrence suggests the existence of negative and positive epistatic interactions. To understand the role of multiple capsules, we queried more than 6700 metagenomes for the presence of species encoding capsules and showed that their distribution varied between environmental categories and, within the human microbiome, between body locations. Species encoding capsules, and especially those encoding multiple capsules, had larger environmental breadths than the other species. Accordingly, capsules were more frequent in environmental bacteria than in pathogens and, within the latter, they were more frequent among facultative pathogens. Nevertheless, capsules were frequent in clinical samples, and were usually associated with fast-growing bacteria with high infectious doses. Our results suggest that capsules increase the environmental range of bacteria and make them more resilient to environmental perturbations. Capsules might allow opportunistic pathogens to profit from empty ecological niches or environmental perturbations, such as those resulting from antibiotic therapy, to colonize the host. Capsule-associated virulence might thus be a by

  11. NMR relaxation dispersion of Miglyol molecules confined inside polymeric micro-capsules.

    Science.gov (United States)

    Nechifor, Ruben; Ardelean, Ioan; Mattea, Carlos; Stapf, Siegfried; Bogdan, Mircea

    2011-11-01

    Frequency dependent NMR relaxation studies have been carried out on Miglyol molecules confined inside core shell polymeric capsules to obtain a correlation between capsule dimension and the measurable parameters. The polymeric capsules were prepared using an interfacial polymerization technique for three different concentrations of Miglyol. It was shown that the variation of Miglyol concentration influences the capsule dimension. Their average size was estimated using the pulsed field gradient diffusometry technique. The relaxation dispersion curves were obtained at room temperature by a combined use of a fast field cycling instrument and a high-field instrument. The frequency dependence of relaxation rate shows a transition from a diffusion-limited to a surface-limited relaxation regime. Copyright © 2011 John Wiley & Sons, Ltd.

  12. X-ray drive of beryllium capsule implosions at the National Ignition Facility

    International Nuclear Information System (INIS)

    Wilson, D C; Yi, S A; Simakov, A N; Kline, J L; Kyrala, G A; Olson, R E; Zylstra, A B; Dewald, E L; Tommasini, R; Ralph, J E; Strozzi, D J; Celliers, P M; Schneider, M B; MacPhee, A G; Callahan, D A; Hurricane, O A; Milovich, J L; Hinkel, D E; Rygg, J R; Rinderknecht, H G

    2016-01-01

    National Ignition Facility experiments with beryllium capsules have followed a path begun with “high-foot” plastic capsule implosions. Three shock timing keyhole targets, one symmetry capsule, a streaked backlit capsule, and a 2D backlit capsule were fielded before the DT layered shot. After backscatter subtraction, laser drive degradation is needed to match observed X-ray drives. VISAR measurements determined drive degradation for the picket, trough, and second pulse. Time dependence of the total Dante flux reflects degradation of the of the third laser pulse. The same drive degradation that matches Dante data for three beryllium shots matches Dante and bangtimes for plastic shots N130501 and N130812. In the picket of both Be and CH hohlraums, calculations over-estimate the x-ray flux > 1.8 keV by ∼100X, while calculating the total flux correctly. In beryllium calculations these X-rays cause an early expansion of the beryllium/fuel interface at ∼3 km/s. VISAR measurements gave only ∼0.3 km/s. The X-ray drive on the Be DT capsule was further degraded by an unplanned decrease of 9% in the total picket flux. This small change caused the fuel adiabat to rise from 1.8 to 2.3. The first NIF beryllium DT implosion achieved 29% of calculated yield, compared to CH capsules with 68% and 21%. (paper)

  13. Implementing Python for DrRacket

    OpenAIRE

    Ramos, Pedro Palma; Leitão, António Menezes

    2014-01-01

    The Python programming language is becoming increasingly popular in a variety of areas, most notably among novice programmers. On the other hand, Racket and other Scheme dialects are considered excellent vehicles for introducing Computer Science concepts. This paper presents an implementation of Python for Racket and the DrRacket IDE. This allows Python programmers to use Racket libraries and vice versa, as well as using DrRacket's pedagogic features. In particular, it allows architects and d...

  14. Brahm Prakash, Dr

    Indian Academy of Sciences (India)

    Home; Fellowship. Fellow Profile. Elected: 1972 Section: Engineering & Technology. Brahm Prakash, Dr Ph.D. (Panjab), FNA 1974-76. Date of birth: 21 August 1912. Date of death: 3 January 1984. Specialization: Metallurgy. YouTube; Twitter; Facebook; Blog ...

  15. Dr. David Syz, State Secretary for Economic Affairs, Switzerland

    CERN Multimedia

    Maximilien Brice

    2003-01-01

    Dr. David Syz, State Secretary for Economic Affairs, Switzerland, toured the assembly hall of the ATLAS experiment on a recent visit to CERN.Photos 01, 02: Dr. Peter Jenni, spokesperson for the ATLAS experiment (second from left), explains to Dr. David Syz (fourth from left) and accompanying visitors the process of integration of a 26-metre-long coil of the barrel toroid magnet system into its coil casing.Photo 03: Dr. Peter Jenni (extreme right) with Dr. David Syz (front row, fourth from right) behind a stack of 26-metre-long 'racetrack' coils awaiting integration into their coil casings.

  16. The development of the nasal capsule of the silver carp ...

    African Journals Online (AJOL)

    The development of the nasal capsule, including the procartilaginous as well as some mesenchymatous developmental stages, is described in the chinese silver carp,. Hypophthalmichthys molitrix (VaL). In the nasal capsule a primitive feature, namely the presence of a complete paraphysial bridge was observed.

  17. Fabrication and operation of HFIR-MFE RB* spectrally tailored irradiation capsules

    International Nuclear Information System (INIS)

    Longest, A.W.; Pawel, J.E.; Heatherly, D.W.; Sitterson, R.G.; Wallace, R.L.

    1993-01-01

    Fabrication and operation of four HFIR-MFE RB * capsules (60, 200, 330, and 400 degrees C) to accommodate MFE specimens previously irradiated in spectrally tailored experiments in the ORR are proceeding satisfactorily. With the exception of the 60 degrees C capsule, where the test specimens were in direct contact with the reactor cooling water, specimen temperatures (monitored by 21 thermocouples) are controlled by varying the thermal conductance of a thin gap region between the specimen holder outer sleeve and containment tube. Irradiation of the 60 and 330 degrees C capsules, which started on July 17, 1990, was completed on November 14, 1992, after 24 cycles of irradiation to an incremental damage level of approximately 10.9 displacements per atom (dpa). Assembly of the follow-up 200 and 400 degrees C capsules was completed in November 1992, and their planned 20-cycle irradiation to approximately 9.1 incremental dpa was started on November 21, 1992. As of February 11, 1993, the 200 and 400 degrees C capsules had successfully completed three cycles of irradiation to approximately 1.4 incremental dpa

  18. Hazarika, Dr Nabajit

    Indian Academy of Sciences (India)

    Hazarika, Dr Nabajit Ph.D. (Tezpur). Date of birth: 17 January 1986. Specialization: Remote Sensing, GIS Applications, Fluvial Geomorphology, Landuse Landcover Studies Address: Dept. of Environmental Science, Nagaland University, Lumami 798 627, Nagaland Contact: Residence: 94354 81256, 97066 71256

  19. Imaging of High-Z doped, Imploded Capsule Cores

    Science.gov (United States)

    Prisbrey, Shon T.; Edwards, M. John; Suter, Larry J.

    2006-10-01

    The ability to correctly ascertain the shape of imploded fusion capsules is critical to be able to achieve the spherical symmetry needed to maximize the energy yield of proposed fusion experiments for the National Ignition Facility. Implosion of the capsule creates a hot, dense core. The introduction of a high-Z dopant into the gas-filled core of the capsule increases the amount of bremsstrahlung radiation produced in the core and should make the imaging of the imploded core easier. Images of the imploded core can then be analyzed to ascertain the symmetry of the implosion. We calculate that the addition of Ne gas into a deuterium gas core will increase the amount of radiation emission while preserving the surrogacy of the radiation and hydrodynamics in the indirect drive NIF hohlraum in the proposed cryogenic hohlraums. The increased emission will more easily enable measurement of asymmetries and tuning of the implosion.

  20. Prakash, Dr Vishweshwaraiah

    Indian Academy of Sciences (India)

    Prakash, Dr Vishweshwaraiah Ph.D. (Mysore), FNASc, FNAE, FRSC,FNAAS. Date of birth: 23 November 1951. Specialization: S&T Policy, Physical Biochemistry, Chemistry of Macromolecules, Biophysics of Proteins, Enzymes & Thermodynamics, Food Chemistry, Nutrition, Food Biotechnology and Food Science Address: ...

  1. Dikshit, Dr Madhu

    Indian Academy of Sciences (India)

    Home; Fellowship. Fellow Profile. Elected: 2000 Section: Medicine. Dikshit, Dr Madhu Ph.D. (Kanpur), FNASc, FNA Council Service: 2016. Date of birth: 21 November 1957. Specialization: Redox Biology, Cardiovascular Pharmacology, Molecular Pharmacology, Neutrophiles and Nitric Oxide Synthase Address: Department ...

  2. Sethunathan, Dr Nambrattil

    Indian Academy of Sciences (India)

    Fellow Profile. Elected: 1986 Section: Plant Sciences. Sethunathan, Dr Nambrattil Ph.D. (Madras), FNA, FNAAS, FNASc. Date of birth: 2 June 1937. Specialization: Environmental Microbiology Address: Flat No. 103, Ushodaya Apartments, Sri Venkateswara Officers' Colony, Ramakrishnapuram, Secunderabad 500 056, A.P.

  3. Mukerji, Dr Mitali

    Indian Academy of Sciences (India)

    Elected: 2014 Section: Medicine. Mukerji, Dr Mitali Ph.D. (IISc). Date of birth: 13 November 1967. Specialization: Functional Genomics, Population Genomics, Ayurgenomics Address: Sr Principal Scientist, Genomics & Molecualr Medicine, Institute of Genomics & Integrative Biology, Sukhdev Vihar, Mathura Road, New Delhi ...

  4. Alternative hot spot formation techniques using liquid deuterium-tritium layer inertial confinement fusion capsules

    International Nuclear Information System (INIS)

    Olson, R. E.; Leeper, R. J.

    2013-01-01

    The baseline DT ice layer inertial confinement fusion (ICF) ignition capsule design requires a hot spot convergence ratio of ∼34 with a hot spot that is formed from DT mass originally residing in a very thin layer at the inner DT ice surface. In the present paper, we propose alternative ICF capsule designs in which the hot spot is formed mostly or entirely from mass originating within a spherical volume of DT vapor. Simulations of the implosion and hot spot formation in two DT liquid layer ICF capsule concepts—the DT wetted hydrocarbon (CH) foam concept and the “fast formed liquid” (FFL) concept—are described and compared to simulations of standard DT ice layer capsules. 1D simulations are used to compare the drive requirements, the optimal shock timing, the radial dependence of hot spot specific energy gain, and the hot spot convergence ratio in low vapor pressure (DT ice) and high vapor pressure (DT liquid) capsules. 2D simulations are used to compare the relative sensitivities to low-mode x-ray flux asymmetries in the DT ice and DT liquid capsules. It is found that the overall thermonuclear yields predicted for DT liquid layer capsules are less than yields predicted for DT ice layer capsules in simulations using comparable capsule size and absorbed energy. However, the wetted foam and FFL designs allow for flexibility in hot spot convergence ratio through the adjustment of the initial cryogenic capsule temperature and, hence, DT vapor density, with a potentially improved robustness to low-mode x-ray flux asymmetry

  5. SATCAP-B: a program for thermal-hydraulic design of 'Saturated Temperature Capsule'

    International Nuclear Information System (INIS)

    Harayama, Yasuo; Someya, Hiroyuki; Niimi, Motoji

    1989-11-01

    As an advanced irradiation technique, the JMTR (Japan Materials Testing Reactor) project is developing a 'Saturated Temperature Capsule' which water is injected in and boiled. When the water is kept at a constant pressure, the water temperature does not become higher than the saturated temperature. This type capsule is based on the conception of keeping the coolant to the saturated temperature and using the temperature control. In designing the capsule in which the inner coolant is injected, thermal performances have to be understood as exactly as possible. Then, a program (named SATCAP) was compiled to graps the thermal performance within the capsule. On the other hand, a 'Saturated Temperature Capsule' was made and irradiated in the JMTR core. It was indicated from supplied water temperatures recorded by thermo-couples attached in the capsule that heat transfer coefficients prefered models due to natural convection to models incorporated in the initial version of the program. Then, the program was revised by adding mainly heat transfer model based on natural convection. The present report describes the calculation procedure and guides of input and output for the revised program (SATCAP version-B). (author)

  6. Mitigate the tent-induced perturbation in ignition capsules by supersonic radiation propagation

    Science.gov (United States)

    Dai, Zhensheng; Gu, Jianfa; Zheng, Wudi

    2017-10-01

    In the inertial confinement fusion (ICF) scheme, to trap the alpha particle products of the D-T reaction, the capsules needs to be imploded and compressed with high symmetry In the laser indirect drive scheme, the capsules are held at the center of high-Z hohlraums by thin membranes (tents). However, the tents are recognized as one of the most important contributors to hot spot asymmetries, areal density perturbations and reduced performance. To improve the capsule implosion performance, various alternatives such as the micro-scale rods, a larger fill-tube and a low-density foam layer around the capsule have been presented. Our simulations show that the radiation propagates supersonically in the low-density foam layer and starts to ablate the capsule before the perturbations induced by the tents reach the ablating fronts. The tent induced perturbations are remarkably weakened when they are propagating in the blow-off plasma.

  7. A hydrogel capsule as gate dielectric in flexible organic field-effect transistors

    Energy Technology Data Exchange (ETDEWEB)

    Dumitru, L. M.; Manoli, K.; Magliulo, M.; Torsi, L., E-mail: luisa.torsi@uniba.it [Department of Chemistry, University of Bari “Aldo Moro”, Via Orabona 4, Bari I-70126 (Italy); Ligonzo, T. [Department of Physics, University of Bari “Aldo Moro”, Via Orabona 4, Bari I-70126 (Italy); Palazzo, G. [Department of Chemistry, University of Bari “Aldo Moro”, Via Orabona 4, Bari I-70126 (Italy); Center of Colloid and Surface Science—CSGI—Bari Unit, Via Orabona 4, Bari I-70126 (Italy)

    2015-01-01

    A jellified alginate based capsule serves as biocompatible and biodegradable electrolyte system to gate an organic field-effect transistor fabricated on a flexible substrate. Such a system allows operating thiophene based polymer transistors below 0.5 V through an electrical double layer formed across an ion-permeable polymeric electrolyte. Moreover, biological macro-molecules such as glucose-oxidase and streptavidin can enter into the gating capsules that serve also as delivery system. An enzymatic bio-reaction is shown to take place in the capsule and preliminary results on the measurement of the electronic responses promise for low-cost, low-power, flexible electronic bio-sensing applications using capsule-gated organic field-effect transistors.

  8. A robust ex vivo model for evaluation of induction of apoptosis by rhTRAIL in combination with proteasome inhibitor MG132 in human premalignant cervical explants

    NARCIS (Netherlands)

    Hougardy, Brigitte M. T.; Reesink-Peters, Nathalie; van den Heuvel, Fiona A. J.; ten Hoor, Klaske A.; Hollema, Harry; de Vries, Elisabeth G. E.; de Jong, Steven; van der Zee, Ate G. J.

    2008-01-01

    Development of medical therapies for high-grade cervical intraepithelial neoplasia (CIN II/III) is hampered by the lack of CIN II/III cell lines. Tumor necrosis factor-related apoptosis-inducing ligand (TRAIL) induces apoptosis upon binding to its receptors DR4 or DR5. Proteasome inhibition by MG132

  9. Thin film drainage between pre-inflated capsules or vesicles

    Science.gov (United States)

    Keh, Martin; Walter, Johann; Leal, Gary

    2013-11-01

    Capsules and vesicles are often used as vehicles to carry active ingredients or fragrance in drug delivery and consumer products and oftentimes in these applications the particles may be pre-inflated due to the existence of a small osmotic pressure difference between the interior and exterior fluid. We study the dynamics of thin film drainage between capsules and vesicles in flow as it is crucial to fusion and deposition of the particles and, therefore, the stability and effectiveness of the products. Simulations are conducted using a numerical model coupling the boundary integral method for the motion of the fluids and a finite element method for the membrane mechanics. For low capillary numbers, the drainage behavior of vesicles and capsules are approximately the same, and also similar to that of drops as the flow-independent and uniform tension due to pre-inflation dominates. The tension due to deformation caused by flow will become more important as the strength of the external flow (i.e. the capillary number) increases. In this case, the shapes of the thin film region are fundamentally different for capsules and vesicles, and the drainage behavior in both cases differs from a drop. Funded by P&G.

  10. Dr. Hans Chang, Director, Physics Research Committee, Stichting voor Fundamenteel Onderzoek der Materie (FOM), Dr. Joris Van Enst, Head of Science Policy Division, Ministry of Education, Culture and S cience, Dr. Jan Bezemer, NL Delegate CERN, Netherlands

    CERN Multimedia

    Patrice Loiez

    1999-01-01

    Dr. Hans Chang, Director, Physics Research Committee, Stichting voor Fundamenteel Onderzoek der Materie (FOM), Dr. Joris Van Enst, Head of Science Policy Division, Ministry of Education, Culture and S cience, Dr. Jan Bezemer, NL Delegate CERN, Netherlands

  11. A probabilistic method for determining the volume fraction of pre-embedded capsules in self-healing materials

    International Nuclear Information System (INIS)

    Lv, Zhong; Chen, Huisu

    2014-01-01

    Autonomous healing of cracks using pre-embedded capsules containing healing agent is becoming a promising approach to restore the strength of damaged structures. In addition to the material properties, the size and volume fraction of capsules influence crack healing in the matrix. Understanding the crack and capsule interaction is critical in the development and design of structures made of self-healing materials. Assuming that the pre-embedded capsules are randomly dispersed we theoretically model flat ellipsoidal crack interaction with capsules and determine the probability of a crack intersecting the pre-embedded capsules i.e. the self-healing probability. We also develop a probabilistic model of a crack simultaneously meeting with capsules and catalyst carriers in two-component self-healing system matrix. Using a risk-based healing approach, we determine the volume fraction and size of the pre-embedded capsules that are required to achieve a certain self-healing probability. To understand the effect of the shape of the capsules on self-healing we theoretically modeled crack interaction with spherical and cylindrical capsules. We compared the results of our theoretical model with Monte-Carlo simulations of crack interaction with capsules. The formulae presented in this paper will provide guidelines for engineers working with self-healing structures in material selection and sustenance. (paper)

  12. Atomic data for dielectronic recombination into Mg-like Fe

    International Nuclear Information System (INIS)

    Murakami, I.; Kato, T.; Kato, D.; Safronova, U.I.; Cowan, T.E.; Ralchenko, Yu.

    2006-03-01

    Energy levels, radiative transition probabilities, and autoionization rates for 1s 2 2s 2 2p 6 3l'nl (n=3-12, l≤n-1) and 1s 2 2s 2 2p 6 4l'nl (n=4-7, l≤n-1) states in Mg-like iron (Fe 14+ ) are calculated by the Hartree-Fock-Relativistic method (Cowan code) and the relativistic many-body perturbation theory method (RMBPT code). Autoionizing levels above three thresholds 1s 2 2s 2 2p 6 3s, 1s 2 2s 2 2p 6 3p, and 1s 2 2s 2 2p 6 3d are considered. It is found that configuration mixing [3sns + 3pnp + 3dnd], [3snp + 3pns + 3pnd + 3dnp] play an important role for all atomic characteristics. Branching ratios relative to the first threshold and intensity factors for satellite lines are calculated, and dielectronic recombination (DR) rate coefficients are determined for the excited 444 odd-parity and 419 even-parity states. It is shown that the contribution of the highly-excited states is very important for calculation of DR rates. Contribution from the excited 1s 2 2s 2 2p 6 3l'nl states with n≥12 and 1s 2 2s 2 2p 6 4l'nl states with n≥7 to DR rate coefficients are estimated by extrapolation of all atomic characteristics. The total DR rate coefficient is derived as a function of electron temperature. (author)

  13. Mukhopadhyay, Dr Sangita

    Indian Academy of Sciences (India)

    Elected: 2013 Section: Medicine. Mukhopadhyay, Dr Sangita Ph.D. (Utkal), FNASc. Date of birth: 1 January 1966. Specialization: Immunology, Cell Signalling, Communicable Diseases Address: Group Leader, Molecular Cell Biology, Centre for DNA Fingerprinting & Diagnostics, Nampally, Hyderabad 500 001, A.P.. Contact ...

  14. Mohanty, Dr Debasisa

    Indian Academy of Sciences (India)

    Home; Fellowship. Fellow Profile. Elected: 2012 Section: General Biology. Mohanty, Dr Debasisa Ph.D. (IISc), FNASc, FNA. Date of birth: 30 November 1966. Specialization: Bioinformatics, Computational & Structural Biology, Biophysics Address: National Institute of Immunology, Aruna Asaf Ali Marg, New Delhi 110 067, ...

  15. Banerjee, Dr Srikumar

    Indian Academy of Sciences (India)

    Fellow Profile. Elected: 1990 Section: Engineering & Technology. Banerjee, Dr Srikumar Ph.D. (IIT, Kharagpur), FNA, FNAE, FNASc, FTWAS Council Service: 2007-12; Vice-President: 2010-12. Date of birth: 25 April 1946. Specialization: Materials Science, Physical Metallurgy, Phase Transformations, Nuclear Fuel Cycle, ...

  16. Authikesavalu, Dr Munisamy

    Indian Academy of Sciences (India)

    Home; Fellowship. Fellow Profile. Elected: 1948 Section: Medicine. Authikesavalu, Dr Munisamy MBBS (Madras), MS (Minneapolis), FRCS. Date of birth: 16 August 1906. Date of death: 22 September 1973. Specialization: Experimental Surgery, Ophthalmology, Otolaryngology Last known address: 5-C, Lavelle Cross Road, ...

  17. Santhanam, Dr Vaidyanathaswamy

    Indian Academy of Sciences (India)

    Elected: 1974 Section: Plant Sciences. Santhanam, Dr Vaidyanathaswamy Ph.D. (Madras). Date of birth: 31 July 1925. Specialization: Plant Breeding & Genetics, Research Management and Cotton Development Address: 'Shri Abhirami', 107, Venkataswamy Road West, R S Puram Post, Coimbatore 641 002, T.N.. Contact:

  18. Amarjit Singh, Dr

    Indian Academy of Sciences (India)

    Home; Fellowship. Fellow Profile. Elected: 1974 Section: Engineering & Technology. Amarjit Singh, Dr Ph.D. (Harvard). Date of birth: 19 November 1924. Specialization: Millimeter Wave Tubes, Microwave Tubes and Microwave Electronics Address: 12, Auburn Court, Vernon Hills, IL 60061, USA Contact: Residence: ...

  19. Chandy, Dr Mammen

    Indian Academy of Sciences (India)

    Home; Fellowship. Fellow Profile. Elected: 2008 Section: Medicine. Chandy, Dr Mammen MD (Madras), FRACP, FRCPA. Date of birth: 30 August 1949. Specialization: Hematology, Bone Marrow Transplantation and Molecular Genetics of Blood Diseases Address: Director, Tata Memorial Centre, 14, Major Arterial Road, ...

  20. Shivaji, Dr Sisinthy

    Indian Academy of Sciences (India)

    Home; Fellowship. Fellow Profile. Elected: 2011 Section: Animal Sciences. Shivaji, Dr Sisinthy Ph.D. (Delhi), FNASc. Date of birth: 17 June 1950. Specialization: Anti-Microbial Resistance, Gut Microbiome, Eye Disease, Conservation Biology, Mammalian Sperm Function, Bacterial Biodiversity of Cold Habitats, Cold ...

  1. Potensi dan Efektivitas Pemungutan Retribusi RSUD Dr. Agoesdjam Ketapang

    OpenAIRE

    B61110063, JAMALUDIN

    2014-01-01

    This study entitled Potential and Effectiveness of retribution collecting in RSUD Dr. Agoesdjam Ketapang which aims to identify and analyze the potential retribution of RSUD Dr . Agoesdjam and also to investigate and analyze the effectiveness of the retribution collecting in RSUD Dr. Agoesdjam . This study uses secondary data , from 2008 to 2012 that were obtained from the Regional Revenue Office of Ketapang and RSUD Dr. Agoesdjam Ketapang . The method of this study is descriptive. To analyz...

  2. Polysaccharide capsule-mediated resistance to opsonophagocytosis in Klebsiella pneumoniae.

    OpenAIRE

    Domenico, P; Salo, R J; Cross, A S; Cunha, B A

    1994-01-01

    The polysaccharide capsule of Klebsiella pneumoniae is an important virulence factor that confers resistance to phagocytosis. The treatment of encapsulated bacteria with salicylate to inhibit capsule expression was found to enhance the phagocytosis of encapsulated bacteria by human neutrophils only in the presence of cell surface-specific antibodies. Both type-specific rabbit antisera and anticapsular human hyperimmune globulin were employed as opsonins. Salicylate significantly enhanced phag...

  3. Evaluation of hard gelatin capsules and hydroxypropyl methylcellulose containing ampicillin

    Directory of Open Access Journals (Sweden)

    Graziella Gonçalves Weigert

    2012-01-01

    Full Text Available This study aims to develop and evaluate formulations containing ampicillin in capsules of gelatin and hydroxypropyl methylcellulose (HPMC. Two formulations (A and B were developed. The final product quality was evaluated by testing for quality control and the results were in agreement with the Brazilian Pharmacopoeia. The formulations with HPMC capsules showed lower percentages of drug dissolved (99.67%, HPMC-A and 87.70%, HPMC-B than the gelatin (100.18%, GEL-A and 101.16% GEL-B. Because of the delay of the ampicillin release observed in the dissolution profiles, it becomes necessary to evaluate the drugs that can be conditioned in the HPMC capsules.

  4. Prevalence and risk factors of adhesive capsulitis of the shoulder after breast cancer treatment.

    Science.gov (United States)

    Yang, Seoyon; Park, Dae Hwan; Ahn, Sei Hyun; Kim, Jisun; Lee, Jong Won; Han, Jun Young; Kim, Dong Kyu; Jeon, Jae Yong; Choi, Kyoung Hyo; Kim, Won

    2017-04-01

    The present study investigated the prevalence and risk factors of adhesive capsulitis of the shoulder in breast cancer patients between 13 and 18 months after surgery. This study included 271 women who underwent surgery for breast cancer with a postoperative period of 13-18 months. Current adhesive capsulitis was defined as restriction of external rotation and one or more additional directional restrictions with history of shoulder pain. Cumulative adhesive capsulitis was defined as current adhesive capsulitis or a previous history of adhesive capsulitis after breast cancer surgery. Multivariate logistic regression analysis was performed to examine associations between current or cumulative adhesive capsulitis and potential risk factors. Among the 271 study patients, 28 (10.3%) and 21 (7.7%) had cumulative or current adhesive capsulitis, respectively. The incidences of cumulative and current adhesive capsulitis were higher in those aged 50-59 years (odds ratio [OR], 9.912; 95% confidence interval [CI], 1.790-54.880; and OR, 12.395; 95% CI, 1.187-129.444, respectively) and those who underwent mastectomy (OR, 6.805; 95% CI, 1.800-25.733; and OR, 9.645; 95% CI, 2.075-44.829, respectively) or mastectomy with reconstruction (OR, 13.122; 95% CI, 2.488-69.218; and OR, 20.075; 95% CI, 2.873-140.261, respectively). Adhesive capsulitis of the shoulder is a common problem after breast cancer treatment. An age of 50-59 years and mastectomy are major risk factors for adhesive capsulitis, and breast reconstruction additionally increases the risk. Patients with these risk factors require greater attention for early diagnosis and proper treatment.

  5. Application of Bio-digestion for Capsule Gelatin-- From the Pharmaceutical Wastes to the Manure

    Science.gov (United States)

    Pan, C.; Huang, S.; Chang, Y.; Wen, J.

    2013-12-01

    The purpose of this study was to bio-digest the capsule gelatin from the waste of pharmaceutical processes such as cutting and stamping for capsule shells producing. We screened soil bacterial flora for capsule gelatin biolysis, and found the most competent one named Yuntech-7. A 15% (w/w) of capsule gelatin could fully digested by Yuntech-7 for 3 days growth with an N-limited medium in a 37°C incubator. In order to recycle and reuse the gelatin waste, the different percentages of capsule gelatin were co-composted with the vegetable residues to produce manure in an anaerobic fermentation by an extra Yuntech-7 inoculation. After 14 days incubation, we collected the filtrate to examine the contents of N, P, and K. The data shows that the P and K keep the same value by roughly between the blank and the control sets, but the total N values were approximately a 5-fold increase in 20% and a 10-fold increase in 40% of capsule gelatin integrated. We suggested that the capsule gelatin was majorly decomposed by Yuntech-7, because the total N value was no observable change in the capsule gelatin and vegetable residues co-compost with a Yuntech-7-free condition. We also performed some field tests using the capsule gelatin generated liquid manure, and the preliminary test shows the plants got great benefits on culture size and in environmental resistance. In conclusion, the process in bio-digestion of waste capsule gelatin by soil bacteria, Yuntech-7, was produced a valuable manure not only aliment the plants but also complement the soil bacterial populations.

  6. Generic Delivery of Payload of Nanoparticles Intracellularly via Hybrid Polymer Capsules for Bioimaging Applications

    Science.gov (United States)

    Sami, Haider; Maparu, Auhin K.; Kumar, Ashok; Sivakumar, Sri

    2012-01-01

    Towards the goal of development of a generic nanomaterial delivery system and delivery of the ‘as prepared’ nanoparticles without ‘further surface modification’ in a generic way, we have fabricated a hybrid polymer capsule as a delivery vehicle in which nanoparticles are loaded within their cavity. To this end, a generic approach to prepare nanomaterials-loaded polyelectrolyte multilayered (PEM) capsules has been reported, where polystyrene sulfonate (PSS)/polyallylamine hydrochloride (PAH) polymer capsules were employed as nano/microreactors to synthesize variety of nanomaterials (metal nanoparticles; lanthanide doped inorganic nanoparticles; gadolinium based nanoparticles, cadmium based nanoparticles; different shapes of nanoparticles; co-loading of two types of nanoparticles) in their hollow cavity. These nanoparticles-loaded capsules were employed to demonstrate generic delivery of payload of nanoparticles intracellularly (HeLa cells), without the need of individual nanoparticle surface modification. Validation of intracellular internalization of nanoparticles-loaded capsules by HeLa cells was ascertained by confocal laser scanning microscopy. The green emission from Tb3+ was observed after internalization of LaF3:Tb3+(5%) nanoparticles-loaded capsules by HeLa cells, which suggests that nanoparticles in hybrid capsules retain their functionality within the cells. In vitro cytotoxicity studies of these nanoparticles-loaded capsules showed less/no cytotoxicity in comparison to blank capsules or untreated cells, thus offering a way of evading direct contact of nanoparticles with cells because of the presence of biocompatible polymeric shell of capsules. The proposed hybrid delivery system can be potentially developed to avoid a series of biological barriers and deliver multiple cargoes (both simultaneous and individual delivery) without the need of individual cargo design/modification. PMID:22649489

  7. Generic delivery of payload of nanoparticles intracellularly via hybrid polymer capsules for bioimaging applications.

    Directory of Open Access Journals (Sweden)

    Haider Sami

    Full Text Available Towards the goal of development of a generic nanomaterial delivery system and delivery of the 'as prepared' nanoparticles without 'further surface modification' in a generic way, we have fabricated a hybrid polymer capsule as a delivery vehicle in which nanoparticles are loaded within their cavity. To this end, a generic approach to prepare nanomaterials-loaded polyelectrolyte multilayered (PEM capsules has been reported, where polystyrene sulfonate (PSS/polyallylamine hydrochloride (PAH polymer capsules were employed as nano/microreactors to synthesize variety of nanomaterials (metal nanoparticles; lanthanide doped inorganic nanoparticles; gadolinium based nanoparticles, cadmium based nanoparticles; different shapes of nanoparticles; co-loading of two types of nanoparticles in their hollow cavity. These nanoparticles-loaded capsules were employed to demonstrate generic delivery of payload of nanoparticles intracellularly (HeLa cells, without the need of individual nanoparticle surface modification. Validation of intracellular internalization of nanoparticles-loaded capsules by HeLa cells was ascertained by confocal laser scanning microscopy. The green emission from Tb(3+ was observed after internalization of LaF(3:Tb(3+(5% nanoparticles-loaded capsules by HeLa cells, which suggests that nanoparticles in hybrid capsules retain their functionality within the cells. In vitro cytotoxicity studies of these nanoparticles-loaded capsules showed less/no cytotoxicity in comparison to blank capsules or untreated cells, thus offering a way of evading direct contact of nanoparticles with cells because of the presence of biocompatible polymeric shell of capsules. The proposed hybrid delivery system can be potentially developed to avoid a series of biological barriers and deliver multiple cargoes (both simultaneous and individual delivery without the need of individual cargo design/modification.

  8. Influence of different excipients on the properties of hard gelatin capsules with metamizole sodium

    Directory of Open Access Journals (Sweden)

    Rogowska Magdalena

    2016-09-01

    Full Text Available Metamizole is an effective non-opioid analgesic drug used in the treatment of acute and chronic pain. Due to induced potentially life-threatening blood disorders, metamizole was withdrawn from market in many parts of the world, however, it is one of the most popular analgesics in Poland that is available as an over the counter drug. Patients tend to prefer capsules over tablets, as they are easier to swallow and taste better. The powder-filled capsules also have greater bioavailability and require less excipients, as compared to tablets. Polymic excipients are mainly used in capsule filling, and have influence upon the physico-chemical properties of the hard gelatin capsules and the powder formulation. The aim of the study was to determine whether various combinations of polymers impact the disintegration time and pharmaceutical availability of hard gelatin capsules with metamizole sodium. The results of our work demonstrated that the 80% of all active substance was released in all tested formulations within 15 minutes. Herein, the capsule containing lactose monohydrate had the longest release (4% after 2 min., while capsules containing mannitol had the fastest release (81.2% after 2 min.. Moreover, the addition of HPMC to capsules with lactose brought about a slight increase in the metamizole release rate, while the addition of PVP 30 to capsules with microcrystalline cellulose slightly accelerated release. This data suggests that the use of different polymers in capsules formulation brings about changes in the physical properties of powders and modifies the release profile of metamizole. In our study, the most preferred formulation was one containing microcrystalline cellulose (good powder properties and fairly fast release.

  9. U-turn type continuous irradiation method and device for radiation-irradiated capsule

    International Nuclear Information System (INIS)

    Kikuchi, Takayuki.

    1997-01-01

    A capsule to be irradiated is moved while being rotated in one of conveying shafts disposed in a reactor to conduct irradiation treatment. Then, the irradiated capsule is made U-turn in the reactor, inserted to the other conveying shaft and moved while being rotated to conduct irradiation treatment again, and then transported out of the reactor. The device comprises a rotational conveying shaft for moving the irradiated capsule while rotating it, a conveying gear for U-turning the irradiated capsule in the reactor and inserting it to the conveying shaft and a driving mechanism for synchronously rotating the conveying gear relative to the conveying shaft at a constant ratio. Mechanical time loss and manual operation time loss can be reduced upon loading and taking up of the irradiated capsule. Then, the amount of irradiation treatment per unit time is increased, and an optional neutron irradiation amount can be obtained thereby enabling to reduce operator's radiation exposure. (N.H.)

  10. Design and testing of tubular polymeric capsules for self-healing of concrete

    Science.gov (United States)

    Araújo, M.; Van Tittelboom, K.; Feiteira, J.; Gruyaert, E.; Chatrabhuti, S.; Raquez, J.-M.; Šavija, B.; Alderete, N.; Schlangen, E.; De Belie, N.

    2017-10-01

    Polymeric healing agents have proven their efficiency to heal cracks in concrete in an autonomous way. However, the bottleneck for valorisation of self-healing concrete with polymeric healing agents is their encapsulation. In the present work, the suitability of polymeric materials such as poly(methyl methacrylate) (PMMA), polystyrene (PS) and poly(lactic acid) (PLA) as carriers for healing agents in self-healing concrete has been evaluated. The durability of the polymeric capsules in different environments (demineralized water, salt water and simulated concrete pore solution) and their compatibility with various healing agents have been assessed. Next, a numerical model was used to simulate capsule rupture when intersected by a crack in concrete and validated experimentally. Finally, two real-scale self-healing concrete beams were made, containing the selected polymeric capsules (with the best properties regarding resistance to concrete mixing and breakage upon crack formation) or glass capsules and a reference beam without capsules. The self-healing efficiency was determined after crack creation by 3-point-bending tests.

  11. Utility of capsule endoscopy for evaluating anthelmintic efficacy in fully conscious dogs.

    Science.gov (United States)

    Lee, Alice C Y; Epe, Christian; Simpson, Kenneth W; Bowman, Dwight D

    2011-11-01

    The current accepted standard for evaluating the efficacy of gastrointestinal anthelmintic drugs is necropsy of infected animals followed by a comparison of worm counts between treated and non-treated groups. In this study capsule endoscopy, a minimally invasive method of imaging the small intestine of humans, is evaluated as a possible alternative to necropsy for the purposes of worm quantification in dogs. Eighteen Beagle dogs were included in this study. These dogs were part of a separate trial intended to determine the efficacy of various candidate parasiticides against Ancylostoma caninum via the necropsy standard. Dogs were inoculated with A. caninum L3s 4 weeks prior to treatment with one of the candidate compounds; a control group (n=8) received no treatment. Capsule endoscopy was performed 6-14 days post-treatment, followed by necropsy the following day. Seventeen dogs had complete examinations, i.e. the capsule traversed the small intestine and reached the colon within the battery life of the capsule. A strong correlation (r(s)=0.87, Pcapsule endoscopy and necropsy. There was no clear relationship between the ability of the capsule endoscope to detect hookworms and either visibility of the intestinal lumen or small intestinal transit time. Generation of a virtual spatial record of hookworm location from the capsule endoscopy data revealed a temporal trend, with the majority of worms present in the proximal small intestine in the morning versus the central to distal small intestine in the afternoon. Worm distribution as determined by capsule endoscopy closely resembled post-mortem findings. In conclusion, capsule endoscopy shows promise as an alternative to necropsy for the enumeration of A. caninum in the canine small intestine, although further work is required to improve completion rates and optimise intestinal examination. Copyright © 2011 Australian Society for Parasitology Inc. Published by Elsevier Ltd. All rights reserved.

  12. Swallowable Wireless Capsule Endoscopy: Progress and Technical Challenges

    Directory of Open Access Journals (Sweden)

    Guobing Pan

    2012-01-01

    Full Text Available Wireless capsule endoscopy (WCE offers a feasible noninvasive way to detect the whole gastrointestinal (GI tract and revolutionizes the diagnosis technology. However, compared with wired endoscopies, the limited working time, the low frame rate, and the low image resolution limit the wider application. The progress of this new technology is reviewed in this paper, and the evolution tendencies are analyzed to be high image resolution, high frame rate, and long working time. Unfortunately, the power supply of capsule endoscope (CE is the bottleneck. Wireless power transmission (WPT is the promising solution to this problem, but is also the technical challenge. Active CE is another tendency and will be the next geneion of the WCE. Nevertheless, it will not come true shortly, unless the practical locomotion mechanism of the active CE in GI tract is achieved. The locomotion mechanism is the other technical challenge, besides the challenge of WPT. The progress about the WPT and the active capsule technology is reviewed.

  13. Capsule performance optimization in the National Ignition Campaigna)

    Science.gov (United States)

    Landen, O. L.; Boehly, T. R.; Bradley, D. K.; Braun, D. G.; Callahan, D. A.; Celliers, P. M.; Collins, G. W.; Dewald, E. L.; Divol, L.; Glenzer, S. H.; Hamza, A.; Hicks, D. G.; Hoffman, N.; Izumi, N.; Jones, O. S.; Kirkwood, R. K.; Kyrala, G. A.; Michel, P.; Milovich, J.; Munro, D. H.; Nikroo, A.; Olson, R. E.; Robey, H. F.; Spears, B. K.; Thomas, C. A.; Weber, S. V.; Wilson, D. C.; Marinak, M. M.; Suter, L. J.; Hammel, B. A.; Meyerhofer, D. D.; Atherton, J.; Edwards, J.; Haan, S. W.; Lindl, J. D.; MacGowan, B. J.; Moses, E. I.

    2010-05-01

    A capsule performance optimization campaign will be conducted at the National Ignition Facility [G. H. Miller et al., Nucl. Fusion 44, 228 (2004)] to substantially increase the probability of ignition by laser-driven hohlraums [J. D. Lindl et al., Phys. Plasmas 11, 339 (2004)]. The campaign will experimentally correct for residual uncertainties in the implosion and hohlraum physics used in our radiation-hydrodynamic computational models before proceeding to cryogenic-layered implosions and ignition attempts. The required tuning techniques using a variety of ignition capsule surrogates have been demonstrated at the OMEGA facility under scaled hohlraum and capsule conditions relevant to the ignition design and shown to meet the required sensitivity and accuracy. In addition, a roll-up of all expected random and systematic uncertainties in setting the key ignition laser and target parameters due to residual measurement, calibration, cross-coupling, surrogacy, and scale-up errors has been derived that meets the required budget.

  14. Capsule performance optimization in the National Ignition Campaign

    International Nuclear Information System (INIS)

    Landen, O. L.; Bradley, D. K.; Braun, D. G.; Callahan, D. A.; Celliers, P. M.; Collins, G. W.; Dewald, E. L.; Divol, L.; Glenzer, S. H.; Hamza, A.; Hicks, D. G.; Izumi, N.; Jones, O. S.; Kirkwood, R. K.; Michel, P.; Milovich, J.; Munro, D. H.; Robey, H. F.; Spears, B. K.; Thomas, C. A.

    2010-01-01

    A capsule performance optimization campaign will be conducted at the National Ignition Facility [G. H. Miller et al., Nucl. Fusion 44, 228 (2004)] to substantially increase the probability of ignition by laser-driven hohlraums [J. D. Lindl et al., Phys. Plasmas 11, 339 (2004)]. The campaign will experimentally correct for residual uncertainties in the implosion and hohlraum physics used in our radiation-hydrodynamic computational models before proceeding to cryogenic-layered implosions and ignition attempts. The required tuning techniques using a variety of ignition capsule surrogates have been demonstrated at the OMEGA facility under scaled hohlraum and capsule conditions relevant to the ignition design and shown to meet the required sensitivity and accuracy. In addition, a roll-up of all expected random and systematic uncertainties in setting the key ignition laser and target parameters due to residual measurement, calibration, cross-coupling, surrogacy, and scale-up errors has been derived that meets the required budget.

  15. Technology Insight: current status of video capsule endoscopy.

    Science.gov (United States)

    Cave, David R

    2006-03-01

    Video capsule endoscopy (VCE) is the most recent major practical and conceptual development in the field of endoscopy. The video capsule endoscope-a small, pill-sized, passive imaging device-has been demonstrated to be the pre-eminent imaging device for disorders of the small intestine. The initial use for VCE was to detect the origin of obscure gastrointestinal bleeding. Several other indications have now been justified, or are in the process of evaluation. More than 200,000 of these disposable devices have been used worldwide, with an extraordinarily good safety record: indeed, the device has been approved for use in children as young as 10 years of age. In addition, a double-ended capsule has now been approved for the evaluation of mucosal disease in the esophagus. The now-widespread deployment of the device into gastrointestinal practice in the US and many other countries suggests that VCE has achieved mainstream utility. The development of similar competitor devices, and devices whose movement can be controlled, is in progress.

  16. MgO melting curve constraints from shock temperature and rarefaction overtake measurements in samples preheated to 2300 K

    OpenAIRE

    Fat'yanov, Oleg V.; Asimow, P. D.

    2014-01-01

    Continuing our effort to obtain experimental constraints on the melting curve of MgO at 100-200 GPa, we extended our target preheating capability to 2300 K. Our new Mo capsule design holds a long MgO crystal in a controlled thermal gradient until impact by a Ta flyer launched at up to 7.5 km/s on the Caltech two-stage light-gas gun. Radiative shock temperatures and rarefaction overtake times were measured simultaneously by a 6-channel VIS/NIR pyrometer with 3 ns time resolution. The majority ...

  17. Dr. Irene Sänger-Bredt, a life for astronautics

    Science.gov (United States)

    Zaganescu, Nicolae-Florin

    2004-12-01

    Irene Bredt (b.1911 at Bonn) obtained her Doctorate in Physics in 1937; in the same year she became a scientific researcher at the German Research Center for Aviation at Trauen, led by Prof. Dr. Eugen Sänger. Soon, the young but efficient Dr. Irene Bredt became the first assistant of Dr. Sänger, who married her (1951). During 1973-1978, Dr. Bredt was in correspondence with Prof. Dr. Nikolae-Florin Zaganescu and helped him to familiarize the Romanian readers with Prof. Sänger's life and achievements. As for Dr. Bredt's life, she specified three main periods of her activity: 1937-1942, when she was researcher in charge of thermodynamic problems of liquid-fuelled rocket engines at Trauen 1942-1945, when she was Senior Researcher in charge of Ramjet in flight performances at Ainring, and also coauthored the Top Secret Technical report entitled 'A Rocket Engine for a Long-Range Bomber', which was finished in 1941 but edited only in 1944 the post world war II period, when she was Scientific Advisor or Director at various civil and military research institutes, universities, etc. Dr. Irene Sänger-Bredt helped her husband to develop many scientific theories like Ramjet thermodynamic theory, and photon rocket theory and also in establishing IAF and IAA. In 1970, Dr. Irene Sänger-Bredt was honored with 'Hermann Oberth Gold Medal' for her impressive scientific activity.

  18. Professor Bakytzhan Abdiraiym Rector of the L. Gumilov Eurasian National University, Astana, Kazakhstan accompanied by Prof. Kairat Kuterbekov, Dr Bekzat Prmantayeva, Dr Kuralay Maksut with the Director-General, Dr Tadeusz Kurtyka, Adviser for Non-Member States, Mrs Julia Andreeva, Department of Information Technologies and Dr Nikolai Zimine, ATLAS Collaboration, Joint Institute for Nuclear Research, Dubna

    CERN Document Server

    Maximilien Brice

    2011-01-01

    Professor Bakytzhan Abdiraiym Rector of the L. Gumilov Eurasian National University, Astana, Kazakhstan accompanied by Prof. Kairat Kuterbekov, Dr Bekzat Prmantayeva, Dr Kuralay Maksut with the Director-General, Dr Tadeusz Kurtyka, Adviser for Non-Member States, Mrs Julia Andreeva, Department of Information Technologies and Dr Nikolai Zimine, ATLAS Collaboration, Joint Institute for Nuclear Research, Dubna

  19. Assessment of patency capsule retention using MR diffusion-weighted imaging

    Energy Technology Data Exchange (ETDEWEB)

    Klang, Eyal; Rozendorn, Noa; Amitai, Michal Marianne [Sheba Medical Center, Department of Diagnostic Imaging, Ramat Gan (Israel); Tel Aviv University, Sackler Faculty of Medicine, Tel Aviv (Israel); Kopylov, Uri; Ben-Horin, Shomron; Lahat, Adi; Yablecovitch, Doron; Eliakim, Rami [Tel Aviv University, Sackler Faculty of Medicine, Tel Aviv (Israel); Sheba Medical Center, Department of Gastroenterology, Ramat Gan (Israel)

    2017-12-15

    Evaluate the ability of MR diffusion-weighted imaging (DWI) to predict patency capsule retention in Crohn's disease (CD). Clinical and imaging data were prospectively reviewed for 80 CD patients following patency capsule administration and MR-DWI under institutional review board (IRB) approval with informed consent. Two radiologists separately assessed the presence/absence of restricted diffusion in the distal ileum. Apparent diffusion coefficients (ADC) from three regions of interest on the ileal wall were averaged. The association between restricted diffusion and retention, and sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were calculated. Ability of ADC to predict retention was assessed with receiver operating characteristic (ROC) curve analysis. Restricted diffusion in the distal ileum was associated with capsule retention (p = 0.001, p < 0.0001). Sensitivity, specificity, PPV and NPV of restricted diffusion for capsule retention were 100.0%, 46.2%, 30.0%, 100% and 100.0%, 56.9%, 34.9%, 100%, respectively, for two radiologists. Accuracy of ADC to predict retention was high (area under the curve = 0.851, p < 0.0001). An ADC of 1.47 mm{sup 2}/s showed 90.0% sensitivity and 50.0% specificity for retention. Sensitivity and NPV of restricted diffusion for patency capsule retention were 100%, suggesting that DWI may predict gastrointestinal tract capability to pass video camera endoscopy. (orig.)

  20. Assessment of patency capsule retention using MR diffusion-weighted imaging

    International Nuclear Information System (INIS)

    Klang, Eyal; Rozendorn, Noa; Amitai, Michal Marianne; Kopylov, Uri; Ben-Horin, Shomron; Lahat, Adi; Yablecovitch, Doron; Eliakim, Rami

    2017-01-01

    Evaluate the ability of MR diffusion-weighted imaging (DWI) to predict patency capsule retention in Crohn's disease (CD). Clinical and imaging data were prospectively reviewed for 80 CD patients following patency capsule administration and MR-DWI under institutional review board (IRB) approval with informed consent. Two radiologists separately assessed the presence/absence of restricted diffusion in the distal ileum. Apparent diffusion coefficients (ADC) from three regions of interest on the ileal wall were averaged. The association between restricted diffusion and retention, and sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were calculated. Ability of ADC to predict retention was assessed with receiver operating characteristic (ROC) curve analysis. Restricted diffusion in the distal ileum was associated with capsule retention (p = 0.001, p < 0.0001). Sensitivity, specificity, PPV and NPV of restricted diffusion for capsule retention were 100.0%, 46.2%, 30.0%, 100% and 100.0%, 56.9%, 34.9%, 100%, respectively, for two radiologists. Accuracy of ADC to predict retention was high (area under the curve = 0.851, p < 0.0001). An ADC of 1.47 mm 2 /s showed 90.0% sensitivity and 50.0% specificity for retention. Sensitivity and NPV of restricted diffusion for patency capsule retention were 100%, suggesting that DWI may predict gastrointestinal tract capability to pass video camera endoscopy. (orig.)

  1. Development of a design methodology for hydraulic pipelines carrying rectangular capsules

    International Nuclear Information System (INIS)

    Asim, Taimoor; Mishra, Rakesh; Abushaala, Sufyan; Jain, Anuj

    2016-01-01

    The scarcity of fossil fuels is affecting the efficiency of established modes of cargo transport within the transportation industry. Efforts have been made to develop innovative modes of transport that can be adopted for economic and environmental friendly operating systems. Solid material, for instance, can be packed in rectangular containers (commonly known as capsules), which can then be transported in different concentrations very effectively using the fluid energy in pipelines. For economical and efficient design of such systems, both the local flow characteristics and the global performance parameters need to be carefully investigated. Published literature is severely limited in establishing the effects of local flow features on system characteristics of Hydraulic Capsule Pipelines (HCPs). The present study focuses on using a well validated Computational Fluid Dynamics (CFD) tool to numerically simulate the solid-liquid mixture flow in both on-shore and off-shore HCPs applications including bends. Discrete Phase Modelling (DPM) has been employed to calculate the velocity of the rectangular capsules. Numerical predictions have been used to develop novel semi-empirical prediction models for pressure drop in HCPs, which have then been embedded into a robust and user-friendly pipeline optimisation methodology based on Least-Cost Principle. - Highlights: • Local flow characteristics in a pipeline transporting rectangular capsules. • Development of prediction models for the pressure drop contribution of capsules. • Methodology developed for sizing of Hydraulic Capsule Pipelines. • Implementation of the developed methodology to obtain optimal pipeline diameter.

  2. Ranganathan, Dr Darshan

    Indian Academy of Sciences (India)

    Elected: 1991 Section: Chemistry. Ranganathan, Dr Darshan Ph.D. (Delhi), FNA. Date of birth: 4 June 1941. Date of death: 4 June 2001. Specialization: Organic Chemistry, Bio-Organic Chemistry and Supramolecular Chemistry Last known address: Scientist, Indian Institue of Chemical, Technology, Uppal Road, Hyderabad ...

  3. Description of Work for Borehole Sampling at the 116-DR-1and 116-DR-2 Trenches

    International Nuclear Information System (INIS)

    Bergstrom, K. A.

    1999-01-01

    This description of work (DOW) details the sampling and analysis activities for characterizing the deep zone soils below the 116-DR-1and 116-DR-2 trenches, which are located in the 100-DR- 1 Operable Unit (OU), and will serve as a guide for the personnel performing the work. The ''deep zone'' refers to the portion of the vadose zone between the bottom of the waste site and the water table. The scope of work includes drilling a borehole (B8786), sampling vadose zone and upper saturated zone soils at ∼ 1-m intervals, collecting a water sample below the top of the water table, and analyzing the samples for all contaminants of concern (COCs). Specific procedures for defined tasks are covered under the Bechtel Hanford, Inc. (BHI)manual, BHI-EE-01, Environmental Investigations Procedures

  4. Goldie Brangman Remembers the Operation to Save Dr King.

    Science.gov (United States)

    Koch, Evan; Brangman, Goldie

    2015-12-01

    In September 1958 the Rev Dr Martin Luther King Jr was stabbed and nearly assassinated. Surgeons at Harlem Hospital in New York City removed a 17.8-cm (7-in)-long letter opener from Dr King's chest. Certified Registered Nurse Anesthetist Goldie Brangman remembers this event because she participated in Dr King's anesthetic. This article correlates Brangman's memories with published accounts of the event. It also places the event within the context of the modern civil rights movement that Dr King led.

  5. The roles of Tenascin C and Fibronectin 1 in adhesive capsulitis: a pilot gene expression study

    Directory of Open Access Journals (Sweden)

    Carina Cohen

    Full Text Available OBJECTIVES: We evaluated mRNA expression levels of genes that encode TGF-β1; the TGF-β1 receptor; the collagen-modifying enzymes LOX, PLOD1, and PLOD2; and the extracellular matrix proteins COMP, FN1, TNC and TNXB in synovial/capsule specimens from patients with idiopathic adhesive capsulitis. Possible associations between the measured mRNA levels and clinical parameters were also investigated. METHODS: We obtained glenohumeral joint synovium/capsule specimens from 9 patients with idiopathic adhesive capsulitis who had not shown improvement in symptoms after 5 months of physiotherapy. Adhesive capsulitis was confirmed in all patients by magnetic resonance imaging. We also obtained specimens from 8 control patients who had underwent surgery for acute acromioclavicular joint dislocation and who had radiological indication of glenohumeral capsule alteration based on arthroscopic evaluation. mRNA expression in the synovium/capsule specimens was analyzed by quantitative reverse transcription PCR. The B2M and HPRT1 genes were used as references to normalize target gene expression in the shoulder tissue samples. RESULTS: The synovium/capsule samples from the patients with adhesive capsulitis had significantly higher TNC and FN1 expression than those from the controls. Additionally, symptom duration directly correlated with expression of TGFβ1 receptor I. CONCLUSION: Elevated levels of TNC and FN1 expression may be a marker of capsule injury. Upregulation of TGFβ1 receptor I seems to be dependent on symptom duration; therefore, TGFβ signaling may be involved in adhesive capsulitis. As such, TNC, FN1 and TGFβ1 receptor I may also play roles in adhesive capsulitis by contributing to capsule inflammation and fibrosis.

  6. Collapse of experimental capsules under external pressure

    International Nuclear Information System (INIS)

    Simonen, F.A.; Shippell, R.J. Jr.

    1980-01-01

    Stress analyses and developmental tests of capsules fabricated from thick-walled tubing were performed for an external pressure design condition. In the design procedure no credit was taken for the expected margin in pressure between yielding of the capsule wall and catastrophic collapse or flattening. In tests of AISI-1018 low carbon steel capsules, a significant margin was seen between yield and collapse pressure. However, the experimental yield pressures were significantly below predictions, essentially eliminating the safety margin present in the conservative design approach. The differences between predictions and test results are attributed to deficiencies in the plasticity theories commonly in use for engineering stress analyses. The results of this study show that the von Mises yield condition does not accurately describe the yield behavior of the AISI-1018 steel tubing material for the triaxial stress conditions of interest. Finite element stress analyses successfully predicted the transition between uniform inward plastic deformation and ovalization that leads to catastrophic collapse. After adjustments to correct for the unexpected yield behavior of the tube material, the predicted pressure-deflection trends were found to follow the experimental data

  7. The application value of capsule endoscopy in diagnosing small intestinal carcinoma

    Directory of Open Access Journals (Sweden)

    Xiaohuan Li

    2018-01-01

    Conclusion: Capsule endoscopy demonstrated a high diagnostic value for various small bowel diseases, including both tumor and inflammatory lesions. Given its simplicity, safety, and reliability, capsule endoscopy was an important examination tool for the diagnosis of small bowel diseases.

  8. Colon Cancer Detection by ‘Rendezvous Colonoscopy’: Successful Removal of Stuck Colon Capsule by Conventional Colonoscopy

    Directory of Open Access Journals (Sweden)

    István Rácz

    2010-02-01

    Full Text Available Although capsule retention is a known complication of small bowel capsule endoscopy, initial studies with colon capsule endoscopy (CCE have not reported any capsule retention or sticking neither in the small bowel nor in the colon. We report a complication of CCE when the stuck colon capsule was passed through the malignant colon stricture and removed by the aid of a flexible colonoscope. During CCE in a 76-year-old iron deficiency anemia patient the real-time viewing system indicated the colon capsule to be stuck in a malignant ascending colon stricture for more than two hours. With the aim to avoid complete capsule retention, immediate colonoscopy was performed. The stuck capsule was caught by a polypectomy snare, passed through the tumor stricture and finally removed from the large bowel. The current case describes the usefulness of the real-time viewing system. Similar situations may occur during the forthcoming spread of CCE and the present case is an example of how to manage the potentially risky stuck colon capsule condition.

  9. Dr. Steve Thompson, Chief Executive, The Royal Society of New Zealand

    CERN Multimedia

    Maximilien Brice

    2002-01-01

    L. to r.: Dr Austin Ball, Deputy Technical Coordinator, CMS experiment; Dr Roland Horisberger, Paul Scherrer Institute and CERN, CMS experiment; Dr Steve Thompson, Chief Executive, The Royal Society of New Zealand; Dr Michel Della Negra, Spokesman, CMS experiment and Dr Alick Macpherson, Paul Scherrer Institute and CERN, CMS experiment, in the CMS Silicon Tracker assembly hall.

  10. Crossed-swords, capsule-pinch technique for capsulotomy in pediatric and/or loose lens cataract extraction.

    Science.gov (United States)

    Snyder, Michael E; Lindsell, Luke B

    2010-02-01

    Puncturing the anterior capsule in a patient with a very soft lens, an elastic capsule, and/or deficient zonular countertraction can be challenging even with a sharp needle or blade. The crossed-swords, capsule-pinch technique capitalizes on opposing forces from 2 needles directed toward each other with a "pinch" of the capsule between their tips. This affords a controlled and facile puncture of the capsule without creating stress on the zonules or anteroposterior displacement of the lens. Copyright 2010 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  11. Bhandari, Dr Nita

    Indian Academy of Sciences (India)

    Elected: 2015 Section: Medicine. Bhandari, Dr Nita Ph.D. (JNU), FAMS. Date of birth: 9 November 1955. Specialization: Nutrition-Infection Interaction, Child Health, Nutritional Interventions, Clinical Evaluation of Vaccine Address: President & Director, Centre for Health R&D Society for Applied Studies, 45, Kalu Sarai, New ...

  12. Chandrasekaran, Dr Chidambara

    Indian Academy of Sciences (India)

    Fellow Profile. Elected: 1945 Section: Mathematical Sciences. Chandrasekaran, Dr Chidambara Ph.D. (London) 1962-64. Date of birth: 30 October 1911. Date of death: 4 January 2000. Specialization: Statistics, Public Health and Demography Last known address: 'Sri Kripa', 79/3, Benson Cross Road, Bengaluru 560 046.

  13. Mukhopadhyay, Dr Amitabha

    Indian Academy of Sciences (India)

    Fellow Profile. Elected: 2010 Section: General Biology. Mukhopadhyay, Dr Amitabha Ph.D. (Jadavpur), FNASc, FNA. Date of birth: 5 February 1959. Specialization: Cell Biology, Host-Pathogen Interactions, Drug Delivery Address: Staff Scientist VII, National Institute of Immunology, Aruna Asaf Ali Marg, New Delhi 110 067, ...

  14. Chandy, Dr Jacob

    Indian Academy of Sciences (India)

    Elected: 1961 Section: Medicine. Chandy, Dr Jacob MBBS (Madras), FRCS (c) Council Service: 1962-70. Date of birth: 23 January 1910. Date of death: 23 June 2007. Specialization: Neurology, Neurosurgery and Medical Education Last known address: Paarra, Matteethra, Kottayam 686 004. YouTube; Twitter; Facebook ...

  15. Adhya, Dr Samit

    Indian Academy of Sciences (India)

    Elected: 1999 Section: General Biology. Adhya, Dr Samit Ph.D. (New York), FNA. Date of birth: 29 September 1953. Specialization: Mitochondrial Biology, Molecular Genetics of Parasites, Intracellular RNA Trafficking and DNA Diagnostics Address: CSIR Emeritus Scientist, Indian Inst. of Chemical Biology, 4, Raja S.C. ...

  16. An O antigen capsule modulates bacterial pathogenesis in Shigella sonnei.

    Science.gov (United States)

    Caboni, Mariaelena; Pédron, Thierry; Rossi, Omar; Goulding, David; Pickard, Derek; Citiulo, Francesco; MacLennan, Calman A; Dougan, Gordon; Thomson, Nicholas R; Saul, Allan; Sansonetti, Philippe J; Gerke, Christiane

    2015-03-01

    Shigella is the leading cause for dysentery worldwide. Together with several virulence factors employed for invasion, the presence and length of the O antigen (OAg) of the lipopolysaccharide (LPS) plays a key role in pathogenesis. S. flexneri 2a has a bimodal OAg chain length distribution regulated in a growth-dependent manner, whereas S. sonnei LPS comprises a monomodal OAg. Here we reveal that S. sonnei, but not S. flexneri 2a, possesses a high molecular weight, immunogenic group 4 capsule, characterized by structural similarity to LPS OAg. We found that a galU mutant of S. sonnei, that is unable to produce a complete LPS with OAg attached, can still assemble OAg material on the cell surface, but a galU mutant of S. flexneri 2a cannot. High molecular weight material not linked to the LPS was purified from S. sonnei and confirmed by NMR to contain the specific sugars of the S. sonnei OAg. Deletion of genes homologous to the group 4 capsule synthesis cluster, previously described in Escherichia coli, abolished the generation of the high molecular weight OAg material. This OAg capsule strongly affects the virulence of S. sonnei. Uncapsulated knockout bacteria were highly invasive in vitro and strongly inflammatory in the rabbit intestine. But, the lack of capsule reduced the ability of S. sonnei to resist complement-mediated killing and to spread from the gut to peripheral organs. In contrast, overexpression of the capsule decreased invasiveness in vitro and inflammation in vivo compared to the wild type. In conclusion, the data indicate that in S. sonnei expression of the capsule modulates bacterial pathogenesis resulting in balanced capabilities to invade and persist in the host environment.

  17. An O antigen capsule modulates bacterial pathogenesis in Shigella sonnei.

    Directory of Open Access Journals (Sweden)

    Mariaelena Caboni

    2015-03-01

    Full Text Available Shigella is the leading cause for dysentery worldwide. Together with several virulence factors employed for invasion, the presence and length of the O antigen (OAg of the lipopolysaccharide (LPS plays a key role in pathogenesis. S. flexneri 2a has a bimodal OAg chain length distribution regulated in a growth-dependent manner, whereas S. sonnei LPS comprises a monomodal OAg. Here we reveal that S. sonnei, but not S. flexneri 2a, possesses a high molecular weight, immunogenic group 4 capsule, characterized by structural similarity to LPS OAg. We found that a galU mutant of S. sonnei, that is unable to produce a complete LPS with OAg attached, can still assemble OAg material on the cell surface, but a galU mutant of S. flexneri 2a cannot. High molecular weight material not linked to the LPS was purified from S. sonnei and confirmed by NMR to contain the specific sugars of the S. sonnei OAg. Deletion of genes homologous to the group 4 capsule synthesis cluster, previously described in Escherichia coli, abolished the generation of the high molecular weight OAg material. This OAg capsule strongly affects the virulence of S. sonnei. Uncapsulated knockout bacteria were highly invasive in vitro and strongly inflammatory in the rabbit intestine. But, the lack of capsule reduced the ability of S. sonnei to resist complement-mediated killing and to spread from the gut to peripheral organs. In contrast, overexpression of the capsule decreased invasiveness in vitro and inflammation in vivo compared to the wild type. In conclusion, the data indicate that in S. sonnei expression of the capsule modulates bacterial pathogenesis resulting in balanced capabilities to invade and persist in the host environment.

  18. H2 gas pressure calculation of FPM capsule failure at RSG-GAS reactor core

    International Nuclear Information System (INIS)

    Hastuti, Endiah Puji; Sunaryo, Geni Rina

    2002-01-01

    RSG-GAS has been irradiated FPM capsule for 236 times, one of those i.e. capsule number 228 has failure. The one of root cause of failure possibility is radiolysis reaction can be occurred in FPM capsule when it is filled with water during irradiation in the reactor core. The safety analysis of the radiolysis reaction in the capsule has been done. The oc cumulative hydrogen gas production can cause high pressure in the capsule then a mechanical damage occurred. The analysis was done at 10 MW of reactor power which equivalent with neutron flux of 0,6929 x 10 1 4 n/cm 2 sec and γ dose rate of 0,63x10 9 rad/hour. The assumption is the capsule is filled with water at maximum volume, i.e. 176.67 ml. The results of calculation showed that radiolysis reaction with γ and neutron produce hydrogen gas for nominal flow rate each are 494 atm and 19683 atm for γ and neutron radiolysis, respectively. H 2 gas pressure for 5% flow rate each are 723 atm. and 25772 atm., for γ and neutron radiolysis, respectively. The changing of the operation condition due to radiolysis together with one way valve' phenomena, can be produce hydrogen gas from water during irradiation in the reactor core and can be the one of root cause of capsule failure. This analysis recommended the FPM capsule preparation must be guaranteed no water or/and there is no possibility of water immersion in the capsule during irradiation in the core by more accurate leak test

  19. Ignition capsules with aerogel-supported liquid DT fuel for the National Ignition Facility

    Directory of Open Access Journals (Sweden)

    Ho D.D.-M.

    2013-11-01

    Full Text Available For high repetition-rate fusion power plant applications, capsules with aerogel-supported liquid DT fuel can have much reduced fill time compared to β-layering a solid DT fuel layer. The melting point of liquid DT can be lowered once liquid DT is embedded in an aerogel matrix, and the DT vapor density is consequently closer to the desired density for optimal capsule design requirement. We present design for NIF-scale aerogel-filled capsules based on 1-D and 2-D simulations. An optimal configuration is obtained when the outer radius is increased until the clean fuel fraction is within 65 – 75% at peak velocity. A scan (in ablator and fuel thickness parameter space is used to optimize the capsule configurations. The optimized aerogel-filled capsule has good low-mode robustness and acceptable high-mode mix.

  20. HLA-DR expression and disease activity in ulcerative colitis

    DEFF Research Database (Denmark)

    Poulsen, L O; Elling, P; Sørensen, Flemming Brandt

    1986-01-01

    and 3 months later. The rectal epithelial cells were HLA-DR-positive in all patients at the first two examinations. After 3 months five patients had changed to an HLA-DR-negative stage, whereas the other seven patients remained HLA-DR-positive. Closer analyses showed that expression/nonexpression of HLA...

  1. Evaluation of capsule endoscopy to detect mucosal lesions associated with gastrointestinal bleeding in dogs.

    Science.gov (United States)

    Davignon, D L; Lee, A C Y; Johnston, A N; Bowman, D D; Simpson, K W

    2016-03-01

    The objective of this study was to examine the utility of capsule endoscopy to detect mucosal abnormalities in dogs with gastrointestinal haemorrhage. Capsules were administered to 2 healthy controls and 8 patients with gastrointestinal haemorrhage. Images were evaluated for quality, gastric emptying time, small intestinal transit time and presence of lesions. There were no adverse effects of capsule endoscopy in dogs weighing from 7·7 to 58 kg. The capsule traversed the entire gastrointestinal tract in 5 of 8 patients, with high quality images obtained in the stomach and small intestine. Gastric emptying time and small intestinal transit time ranged from 1 to 270 and 15 to 180 minutes, respectively. In 3 of 8 patients, the capsule remained in the stomach despite pro-kinetics. Gastric lesions included mild haemorrhage and pinpoint erosion (4 of 8), a mass (1) and thickened bleeding pyloric mucosa (2). Two of 3 dogs with capsule retention had gastric lesions. Intestinal lesions included a healing duodenal ulcer, abnormal villi, ileal ulceration and colonic bleeding. Lesions identified by capsule endoscopy were considered a significant source of haemorrhage in 4 of 7 dogs with active bleeding. The relevance of pinpoint gastric mucosal erosions to blood loss is unclear. Capsule endoscopy can enable the non-invasive detection of gastric and small intestinal mucosal lesions in dogs presenting for evaluation of gastrointestinal bleeding. © 2016 British Small Animal Veterinary Association.

  2. HLA-DR-expressing cells and T-lymphocytes in sural nerve biopsies

    DEFF Research Database (Denmark)

    Schrøder, H D; Olsson, T; Solders, G

    1988-01-01

    was confirmed. HLA-DR expression was found in all biopsies and thus was not restricted to any particular type of neuropathy. The HLA-DR expression appeared to correlate with severity and activity of the neuropathy. HLA-DR-expressing macrophages wrapping myelinated fibers were prominent in primary demyelinating......Thirty-five sural nerve biopsies were stained immunohistochemically for HLA-DR antigen. HLA-DR was expressed on nonmyelinating Schwann cells, macrophages, vascular endothelium, and perineurium. By means of double immunofluorescence staining the identity of the HLA-DR presenting structures...

  3. Effects of compound amino acids capsule on the immunological function of naval servicemen

    Directory of Open Access Journals (Sweden)

    Hai-zhong ZHONG

    2012-01-01

    Full Text Available Objective  To investigate the effects of the compound amino acids capsule on the immunological function of the naval servicemen during military activity. Methods  The subjects included 100 officers and soldiers, whose Modified Fatigue Rating Scale (MFIS scores were >21 points. The participants were randomly divided into two groups, namely, the amino acids capsule group and placebo group (n=50. Under the condition of military operations, either amino acids capsule (8 kinds of essential amino acids and 11 kinds of vitamins were contained or placebo capsule was given for 14 days continuously. The humoral immune indices, i.e., IgG, IgA, IgM, and complements C3 and C4, were measured with immunoturbidimetry. The percentage of peripheral blood CD subsets was measured using flow cytometry on the first day and 14th day. Results  The levels of IgG, IgM, and complement C3 in the capsule group were significantly higher on the 14th day than on the first day (P+CD4+ T lymphocytes and CD3-CD19+ B lymphocytes in the capsule group on the 14th day were higher than those on the first day, whereas the CD3-CD56+ NK lymphocytes decreased significantly (PConclusion  Compound amino acids capsule can improve the humoral and cellular immunological function of naval servicemen.

  4. Development of a sealing process of capsules for surveillance test tubes of the vessel in nuclear power plants

    International Nuclear Information System (INIS)

    Romero C, J.; Fernandez T, F.; Perez R, N.; Rocamontes A, M.; Garcia R, R.

    2007-01-01

    The surveillance capsule is composed by the support, three capsules for impact test tubes, five capsules for tension test tubes and one porta dosemeters. The capsules for test tubes are of two types: rectangular capsule for Charpy test tubes and cylindrical capsule for tension test tubes. This work describes the development of the welding system to seal the capsules for test tubes that should contain helium of ultra high purity to a pressure of 1 atmosphere. (Author)

  5. Capsules with evolving brittleness to resist the preparation of self-healing concrete

    Directory of Open Access Journals (Sweden)

    Gruyaert, E.

    2016-09-01

    Full Text Available Capsules for self-healing concrete have to possess multifunctional properties and it would be an enormous advantage in the valorization process when they could also be mixed in. Therefore, we aimed to develop capsules with evolving brittleness. Capsules with high initial flexibility were prepared by adding a plasticizer to an ethyl cellulose matrix. During hardening of the concrete, the plasticizing agent should leach out to the moist environment yielding more brittle capsules which break upon crack appearance. The tested capsules could easily be mixed in during concrete production. However, incompatibility issues between the capsule wall and the inner polymeric healing agent appeared. Moreover, the capsules became insufficiently brittle and the bond strength to the cementitious matrix was too weak. Consequently, multilayer capsules were tested. These capsules had a high impact resistance to endure concrete mixing and were able to break upon crack formation.Las cápsulas para la auto-reparación del hormigón tienen que poseer propiedades multifuncionales. Una enorme ventaja en el proceso para su valorización se obtendría si aquellas pudieran resistir con éxito el mezclado. Por lo tanto, nos propusimos desarrollar cápsulas cuya fragilidad evoluciona. Cápsulas con una alta flexibilidad inicial se prepararon mediante la adición de un plastificante a una matriz de etil celulosa. Durante el endurecimiento del hormigón, el agente plastificante debe filtrarse hacia el medio ambiente húmedo produciendo cápsulas más frágiles que se rompen con el surgimiento de fisuras. Las cápsulas pudieron ser fácilmente mezcladas durante la producción de hormigón. Sin embargo, aparecieron problemas de incompatibilidad entre la pared de la cápsula y el agente de curación polimérico interior. Por otra parte, las cápsulas se comportaron insuficientemente frágiles y con una baja adherencia hacia la matriz cementicia. En consecuencia, se probaron las c

  6. Small-bowel capsule endoscopy in patients with suspected Crohn's disease-diagnostic value and complications.

    Science.gov (United States)

    Figueiredo, Pedro; Almeida, Nuno; Lopes, Sandra; Duque, Gabriela; Freire, Paulo; Lérias, Clotilde; Gouveia, Hermano; Sofia, Carlos

    2010-01-01

    The aim of this work was to assess the value of capsule enteroscopy in the diagnosis of patients with suspected Crohn's Disease (CD). Methods. This was a retrospective study in a single tertiary care centre involving patients undergoing capsule enteroscopy for suspected CD. Patients taking nonsteroidal anti inflammatory drugs during the thirty preceding days or with a follow-up period of less than six months were excluded. Results. Seventy eight patients were included. The endoscopic findings included mucosal breaks in 50%, ulcerated stenosis in 5%, and villous atrophy in 4%. The diagnosis of CD was established in 31 patients. The sensitivity, specificity, positive and negative predictive value of the endoscopic findings were 93%, 80%, 77%, and 94%, respectively. Capsule retention occurred in four patients (5%). The presence of ulcerated stenosis was significantly more frequent in patients with positive inflammatory markers. The diagnostic yield of capsule enteroscopy in patients with negative ileoscopy was 56%, with a diagnostic acuity of 93%. Small bowel capsule endoscopy is a safe and valid technique for assessing patients with suspected CD. Capsule retention is more frequent in patients with positive inflammatory markers. Patients with negative ileoscopy and suspected CD should be submitted to capsule enteroscopy.

  7. Welding iridium heat-source capsules for space missions

    International Nuclear Information System (INIS)

    Kanne, W.R. Jr.

    1982-03-01

    A remote computer-controlled welding station was developed to encapsulate radioactive PuO 2 in iridium. Weld quench cracking caused an interruption in production of capsules for upcoming space missions. Hot crack sensitivity of the DOP-26 iridium alloy was associated with low melting constituents in the grain boundaries. The extent of cracking was reduced but could not be eliminated by changes to the welding operation. An ultrasonic test was developed to detect underbead cracks exceeding a threshold size. Production was continued using the ultrasonic test to reject capsules with detectable cracks

  8. Capsule of parotid gland tumor: evaluation by 3.0 T magnetic resonance imaging using surface coils

    International Nuclear Information System (INIS)

    Ishibashi, Mana; Fujii, Shinya; Nishihara, Keisuke; Matsusue, Eiji; Kodani, Kazuhiko; Kaminou, Toshio; Ogawa, Toshihide; Kawamoto, Katsuyuki

    2010-01-01

    Background: Magnetic resonance (MR) imaging of parotid gland tumors has been widely reported, although few reports have evaluated the capsule of parotid gland tumors in detail. Purpose: To evaluate the diagnostic usefulness of 3.0 T MR imaging with surface coils for detection of the parotid gland tumor capsule, and to clarify the characteristics of the capsules. Material and Methods: Seventy-eight patients with parotid gland tumors (63 benign and 15 malignant) were evaluated. Axial and coronal T2-weighted and contrast-enhanced T1-weighted images were obtained using a 3.0 T MR scanner with 70 mm surface coils. It was retrospectively assessed whether each parotid gland tumor was completely surrounded by a capsule. The capsule was classified as regular or irregular in terms of capsular thickness, and as none, mildly, or strongly enhancing in terms of contrast enhancement. Visual interpretations were compared with histopathological findings to evaluate the diagnostic ability of MR imaging to detect parotid gland tumor capsules. Statistical evaluation was conducted concerning the presence of capsules, capsular irregularity, and the difference in contrast enhancement between benign and malignant tumors, and that between pleomorphic adenomas and Warthin's tumors. Results: Capsules completely surrounding the tumor on MR imaging yielded a sensitivity of 87.7% (50/57), specificity of 90.5% (19/21), and accuracy of 88.5% (69/78). Benign tumors had a capsule completely surrounding the tumor significantly more often than malignant tumors (P = 0.009). Concerning capsular irregularity, malignant tumors tended to have more irregular capsules than benign tumors, although there were no significant differences. The capsules of malignant tumors enhanced significantly more strongly than those of benign tumors (P = 0.018). Conclusion: 3.0 T MR imaging using surface coils could correctly depict parotid gland tumor capsules in most cases. Most benign and some malignant tumors had capsules

  9. Varadarajan, Dr Srinivasan

    Indian Academy of Sciences (India)

    Elected: 1972 Section: Chemistry. Varadarajan, Dr Srinivasan Ph.D. (Delhi and Cantab), D.Sc. (h.c.), D.Litt. (h.c.), FNA, FNAE, FTWAS Council Service:1974-88; Vice-President: 1977-79; President: 1980-82. Date of birth: 31 March 1928. Specialization: Organic & Biological Chemistry, Molecular Biology, Engineering Design ...

  10. Sengupta, Dr Sagar

    Indian Academy of Sciences (India)

    Sengupta, Dr Sagar Ph.D. (IISc), FNA, FNASc. Date of birth: 23 June 1968. Specialization: Cancer Biology, Cell Signalling, Mytochondrial Biology Address: National Institute of Immunology, Aruna Asaf Ali Marg, New Delhi 110 067, U.T.. Contact: Office: (011) 2670 3786. Residence: (0124) 422 7107. Mobile: 93131 05470

  11. Sengupta, Dr Sagar

    Indian Academy of Sciences (India)

    Fellow Profile. Elected: 2017 Section: General Biology. Sengupta, Dr Sagar Ph.D. (IISc), FNA, FNASc. Date of birth: 23 June 1968. Specialization: Cancer Biology, Cell Signalling, Mytochondrial Biology Address: National Institute of Immunology, Aruna Asaf Ali Marg, New Delhi 110 067, U.T.. Contact: Office: (011) 2670 3786

  12. Small-incision 4-point scleral suture fixation of a foldable hydrophilic acrylic intraocular lens in the absence of capsule support.

    Science.gov (United States)

    Terveen, Daniel C; Fram, Nicole R; Ayres, Brandon; Berdahl, John P

    2016-02-01

    To determine the visual outcomes and complications of a new small-incision technique for 4-point fixation of a hydrophilic acrylic posterior chamber intraocular lens (IOL) in the absence of capsule support. Three North American tertiary referral centers and a private practice. Retrospective case series. Secondary IOL placement was performed from 2011 to 2014. Indications for surgery, clinical results, and complications were analyzed. Primary outcomes included postoperative corrected distance visual acuity (CDVA) and surgical complications. Charts of 35 patients (37 eyes) were reviewed. The mean age at surgery was 56 years, and the mean follow-up was 6 months (range 3 to 24 months). Clinical indications included a dislocated IOL (30%), ocular trauma (19%), crystalline lens subluxation (19%), uveitis-glaucoma-hyphema syndrome (5%), post-complicated cataract (8%), congenital cataract (8%), and decompensated cornea (3%). The mean CDVA improved from 20/80 preoperatively to 20/40 postoperatively (P IOL dislocation (3%). Small-incision 4-point scleral fixation of the Akreos AO60 hydrophilic acrylic IOL in the absence of capsule support appears to be a safe and effective technique for secondary IOL placement. Drs. Berdahl and Ayres are consultants to Bausch & Lomb, Inc. Drs. Ayres and Fram have received speaker fees from Bausch & Lomb. Dr. Terveen does not have a financial or proprietary interest in any material or methods mentioned. Copyright © 2016 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  13. Fabrication of mechanical system of the FPM capsule puller

    International Nuclear Information System (INIS)

    Sudirdjo, Hari; Prasetya, Hendra

    2000-01-01

    A mechanical system of the FPM capsule puller has been fabricated, which has a function to pull the irradiated FPM capsule. The construction of the system consist of driving motor equipped with reduction gear, spindle, and puller wire. The system has puller stroke of 700 mm, therefore the puller will be terminated at the outside of the reactor core. A function test had been done and shows that the system has fulfilled the requirements

  14. Neuro-fuzzy Classification System for Wireless-Capsule Endoscopic Images

    OpenAIRE

    Vassilis S. Kodogiannis; John N. Lygouras

    2008-01-01

    In this research study, an intelligent detection system to support medical diagnosis and detection of abnormal lesions by processing endoscopic images is presented. The images used in this study have been obtained using the M2A Swallowable Imaging Capsule - a patented, video color-imaging disposable capsule. Schemes have been developed to extract texture features from the fuzzy texture spectra in the chromatic and achromatic domains for a selected region of interest from ...

  15. A modular and programmable development platform for capsule endoscopy system.

    Science.gov (United States)

    Khan, Tareq Hasan; Shrestha, Ravi; Wahid, Khan A

    2014-06-01

    The state-of-the-art capsule endoscopy (CE) technology offers painless examination for the patients and the ability to examine the interior of the gastrointestinal tract by a noninvasive procedure for the gastroenterologists. In this work, a modular and flexible CE development system platform consisting of a miniature field programmable gate array (FPGA) based electronic capsule, a microcontroller based portable data recorder unit and computer software is designed and developed. Due to the flexible and reprogrammable nature of the system, various image processing and compression algorithms can be tested in the design without requiring any hardware change. The designed capsule prototype supports various imaging modes including white light imaging (WLI) and narrow band imaging (NBI), and communicates with the data recorder in full duplex fashion, which enables configuring the image size and imaging mode in real time during examination. A low complexity image compressor based on a novel color-space is implemented inside the capsule to reduce the amount of RF transmission data. The data recorder contains graphical LCD for real time image viewing and SD cards for storing image data. Data can be uploaded to a computer or Smartphone by SD card, USB interface or by wireless Bluetooth link. Computer software is developed that decompresses and reconstructs images. The fabricated capsule PCBs have a diameter of 16 mm. An ex-vivo animal testing has also been conducted to validate the results.

  16. DR6 as a diagnostic and predictive biomarker in adult sarcoma.

    Directory of Open Access Journals (Sweden)

    Kun Yang

    Full Text Available The Death Receptor 6 (DR6 protein is elevated in the serum of ovarian cancer patients. We tested DR6 serum protein levels as a diagnostic/predictive biomarker in several epithelial tumors and sarcomas.DR6 gene expression profiles were screened in publically available arrays of solid tumors. A quantitative immunofluorescent western blot analysis was developed to test the serum of healthy controls and patients with sarcoma, uterine carcinosarcoma, bladder, liver, and pancreatic carcinomas. Change in DR6 serum levels was used to assay the ability of DR6 to predict the response to therapy of sarcoma patients.DR6 mRNA is highly expressed in all tumor types assayed. Western blot analysis of serum DR6 protein demonstrated high reproducibility (r = 0.97. Compared to healthy donor controls, DR6 serum levels were not elevated in patients with uterine carcinosarcoma, bladder, liver, or pancreatic cancers. Serum DR6 protein levels from adult sarcoma patients were significantly elevated (p<0.001. This was most evident for patients with synovial sarcoma. Change in serum DR6 levels during therapy correlated with clinical benefit from therapy (sensitivity 75%, and positive predictive value 87%.DR6 may be a clinically useful diagnostic and predictive serum biomarker for some adult sarcoma subtypes.Diagnosis of sarcoma can be difficult and can lead to improper management of these cancers. DR6 serum protein may be a tool to aid in the diagnosis of some sarcomatous tumors to improve treatment planning. For patients with advanced disease, rising DR6 levels predict non-response to therapy and may expedite therapeutic decision making and reduce reliance on radiologic imaging.

  17. Effects of lipophilic components on the compatibility of lipid-based formulations with hard gelatin capsules.

    Science.gov (United States)

    Chen, Feng-Jing; Etzler, Frank M; Ubben, Johanna; Birch, Amy; Zhong, Li; Schwabe, Robert; Dudhedia, Mayur S

    2010-01-01

    The present study investigated the effect of lipophilic components on the compatibility of propylene glycol (PG)-containing lipid-based drug delivery system (LBDDS) formulations with hard gelatin capsules. The presence of a lipophilic active pharmaceutical ingredient (API) (log P approximately 6.1) and an additional lipophilic excipient (Capmul MCM) significantly affected the activity of PG in the fills and the equilibrium of PG between capsule shells and fills. These changes in activity and equilibrium of PG were furthermore correlated to the mechanical and thermal properties of the liquid-filled capsules and subsequently linked to the shelf-life of the capsules on stability with respect to capsule deformation. The present study also investigated the mechanism by which lipophilic component(s) might affect the activity of PG in the fill formulations and the equilibrium of PG between capsule shells and fills. The activities of PG in two series of "binary" mixtures with Capmul MCM and with Cremophor EL were measured, respectively. The mixtures of PG containing Capmul MCM were found to be more nearly ideal than those containing Cremophor EL. The observed negative deviation from Rauolt's law indicates that the excess free energies of mixing are less then zero indicating favorable interaction between PG and the other component. It is speculated that enhanced hydrogen bonding opportunities with Cremophor EL are responsible for the decreased excess free energy of mixing. Replacement of Cremophor EL with lipophilic API also reduces the hydrogen bonding opportunities for PG in the mixtures. This hypothesis may further explain the increased activity of PG in the fills and the shifted equilibrium of PG toward the capsule shells. Activity determination utilizing headspace gas chromatography (GC) using short 30 min incubation time seems to be a time-efficient approach for assessing capsule-fill compatibility. Direct measurements of PG migration and other physical properties of

  18. Gaia DR2 documentation Chapter 7: Variability

    Science.gov (United States)

    Eyer, L.; Guy, L.; Distefano, E.; Clementini, G.; Mowlavi, N.; Rimoldini, L.; Roelens, M.; Audard, M.; Holl, B.; Lanzafame, A.; Lebzelter, T.; Lecoeur-Taïbi, I.; Molnár, L.; Ripepi, V.; Sarro, L.; Jevardat de Fombelle, G.; Nienartowicz, K.; De Ridder, J.; Juhász, Á.; Molinaro, R.; Plachy, E.; Regibo, S.

    2018-04-01

    This chapter of the Gaia DR2 documentation describes the models and methods used on the 22 months of data to produce the Gaia variable star results for Gaia DR2. The variability processing and analysis was based mostly on the calibrated G and integrated BP and RP photometry. The variability analysis approach to the Gaia data has been described in Eyer et al. (2017), and the Gaia DR2 results are presented in Holl et al. (2018). Detailed methods on specific topics will be published in a number of separate articles. Variability behaviour in the colour magnitude diagram is presented in Gaia Collaboration et al. (2018c).

  19. Simulation-Aided Design of Tubular Polymeric Capsules for Self-Healing Concrete

    Science.gov (United States)

    Šavija, Branko; Feiteira, João; Araújo, Maria; Chatrabhuti, Sutima; Raquez, Jean-Marie; Van Tittelboom, Kim; Gruyaert, Elke; De Belie, Nele; Schlangen, Erik

    2016-01-01

    Polymeric capsules can have an advantage over glass capsules used up to now as proof-of-concept carriers in self-healing concrete. They allow easier processing and afford the possibility to fine tune their mechanical properties. Out of the multiple requirements for capsules used in this context, the capability of rupturing when crossed by a crack in concrete of a typical size is one of the most relevant, as without it no healing agent is released into the crack. This study assessed the fitness of five types of polymeric capsules to fulfill this requirement by using a numerical model to screen the best performing ones and verifying their fitness with experimental methods. Capsules made of a specific type of poly(methyl methacrylate) (PMMA) were considered fit for the intended application, rupturing at average crack sizes of 69 and 128 μm, respectively for a wall thickness of ~0.3 and ~0.7 mm. Thicker walls were considered unfit, as they ruptured for crack sizes much higher than 100 μm. Other types of PMMA used and polylactic acid were equally unfit for the same reason. There was overall good fitting between model output and experimental results and an elongation at break of 1.5% is recommended regarding polymers for this application. PMID:28772370

  20. Renal capsule for augmentation cystoplasty in canine model: a favorable biomaterial?

    Directory of Open Access Journals (Sweden)

    Mehdi Salehipour

    2016-04-01

    Full Text Available ABSTRACT Purpose: To evaluate effectiveness of canine renal capsule for augmentation cystoplasty. Materials and Methods: Ten adult dogs participated in this study. After induction of anesthesia each animal underwent bed side urodynamic study, bladder capacity and bladder pressure was recorded. Then via mid line incision abdominal cavity was entered, right kidney was identified and its capsule was dissected. Bladder augmentation was done by anastomosing the renal capsule to the bladder. After 6 months bed side urodynamic study was performed again and changes in bladder volume and pressure were recorded. Then the animals were sacrificed and the augmented bladders were sent for histopathology evaluation. Results: Mean maximum anatomic bladder capacity before cystoplasty was 334.00±11.40cc which increased to 488.00±14.83cc post-operatively (p=0.039. Mean anatomic bladder pressure before cystoplasty was 19.00±1.58cmH2O which decreased to 12.60±1.14cmH2O post-operatively (p=0.039. Histopathology evaluation revealed epithelialization of the renal capsule with urothelium without evidence of fibrosis, collagen deposits or contracture. Conclusions: Our data shows that renal capsule is a favorable biomaterial for bladder augmentation in a canine model.

  1. Vibration test report on the instrumented capsule for fuel irradiation test

    Energy Technology Data Exchange (ETDEWEB)

    Ryu, Jeong Soo; Yoon, D. B.; Wu, J. S.; Oh, J. M.; Park, S. J.; Cho, M. S.; Kim, B. G.; Kang, Y. W

    2003-01-01

    The fluid-induced vibration level of instrumented capsule, which was manufactured for fuel irradiation test at the reactor core of HANARO, was investigated. For this purpose, the instrumented capsule was loaded at the OR site of the HANARO design verification test facility that could simulate identical flow condition as the HANARO core. Then, vibration signals of the instrumented capsule subjected to various flow conditions were measured by using vibration sensors. In time domain analysis, maximum amplitudes and RMS values of the measured acceleration and displacement signals were obtained. By using frequency domain analysis, frequency components of the fluid-induced vibration were analyzed. In addition, natural frequencies of the instrumented capsule were obtained by performing modal test. The frequency analysis results showed that the natural frequency components near 7.5Hz and 17.5Hz were dominant in the fluid-induced vibration signal. The maximum amplitude of the accelerations was measured as 12.04m/s{sup 2} that is within the allowable vibrational limit(18.99m/s{sup 2})of the reactor structure. Also, the maximum displacement amplitude was calculated as 0.191mm. Since these vibration levels are remarkably low, excessive vibration is not expected when the irradiation test of the instrumented capsule is performed at the HANARO core.

  2. Jameel, Dr Shahid

    Indian Academy of Sciences (India)

    Jameel, Dr Shahid Ph.D. (Washington State Univ.), FNASc, FNA. Date of birth: 8 August 1957. Specialization: Molecular Biology and Molecular Virology Address: Chief Executive Officer, The Wellcome Trust/DBT India Alliance, 8-2-684/3/K/19, Kaushik Society, Road NO. 12, Banjara Hills, Hyderabad 500 034, A.P.. Contact:

  3. Thulium oxide fuel characterization study (thulium-170 fueled capsule parametric design)

    Energy Technology Data Exchange (ETDEWEB)

    DesChamps, N.H.

    1968-10-01

    A doubly encapsulated thulia wafer, i.e., individually lined wafers stacked one upon another inside a fuel capsule was studied. The temperature profiles were determined for thulia power densities ranging from 8 to 24 W/cc and fuel capsule surface temperatures ranging from 1000/sup 0/F (538/sup 0/C) to 2000/sup 0/F (1093/sup 0/C). Parametric studies were also carried out on a singly encapsulated configuration in which the thulia wafers were stacked face to face in an infinitely long, lined cylinder. The doubly encapsulated wafer configuration yielded a lower centerline temperature than the singly encapsulated capsule. Only in extreme cases of a large wafer diameter in combination with a high thulia power density did the fuel capsule centerline temperature exceed the thulia melt temperature of 4172/sup 0/F (2300/sup 0/C). Results are also given for the maximum radius attainable without having centerline melting when using a thulia microsphere fuel form.

  4. Multicenter evaluation of efficacy and safety of low-dose versus high-dose valganciclovir for prevention of cytomegalovirus disease in donor and recipient positive (D+/R+) renal transplant recipients.

    Science.gov (United States)

    Heldenbrand, Seth; Li, Chenghui; Cross, Rosemary P; DePiero, Kelly A; Dick, Travis B; Ferguson, Kara; Kim, Miae; Newkirk, Erin; Park, Jeong M; Sudaria-Kerr, Janice; Tichy, Eric M; Ueda, Kimi R; Weng, Renee; Wisniewski, Jesse; Gabardi, Steven

    2016-12-01

    The cytomegalovirus (CMV) donor-positive/recipient-positive (D+/R+) population is the largest proportion of renal transplant recipients (RTR). Guidelines for prevention of CMV in the intermediate-risk D+/R+ population include prophylaxis with valganciclovir (VGCV) 900 mg/day for 3 months. This study is the first head-to-head analysis, to our knowledge, comparing the efficacy and safety CMV prophylaxis of VGCV 450 vs 900 mg/day for 3 months in D+/R+ RTR. A multicenter, retrospective analysis evaluated 478 adult RTR between January 2008 and October 2011. Study participants received VGCV 450 mg/day (Group 1; n=398) or 900 mg/day (Group 2; n=89)×3 months for CMV prophylaxis. All VGCV was adjusted for renal function. All groups included in this study received study-approved induction and maintenance immunosuppression regimens. The primary endpoint was incidence of CMV disease at 12 months. The rates of graft loss, patient survival, T-cell and/or antibody-mediated rejection, hematological adverse events, opportunistic infections, and early VGCV discontinuation were evaluated. Patient demographics were comparable, but had significant differences in ethnicity and donor type between the groups. The occurrence of CMV disease at 12 months was similar between the groups (3.5% vs 3.4%; P=1.000). Log-rank test found no statistically significant difference in the time to development of CMV between the 2 groups (P=.939). © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  5. Validating Inertial Confinement Fusion (ICF) predictive capability using perturbed capsules

    Science.gov (United States)

    Schmitt, Mark; Magelssen, Glenn; Tregillis, Ian; Hsu, Scott; Bradley, Paul; Dodd, Evan; Cobble, James; Flippo, Kirk; Offerman, Dustin; Obrey, Kimberly; Wang, Yi-Ming; Watt, Robert; Wilke, Mark; Wysocki, Frederick; Batha, Steven

    2009-11-01

    Achieving ignition on NIF is a monumental step on the path toward utilizing fusion as a controlled energy source. Obtaining robust ignition requires accurate ICF models to predict the degradation of ignition caused by heterogeneities in capsule construction and irradiation. LANL has embarked on a project to induce controlled defects in capsules to validate our ability to predict their effects on fusion burn. These efforts include the validation of feature-driven hydrodynamics and mix in a convergent geometry. This capability is needed to determine the performance of capsules imploded under less-than-optimum conditions on future IFE facilities. LANL's recently initiated Defect Implosion Experiments (DIME) conducted at Rochester's Omega facility are providing input for these efforts. Recent simulation and experimental results will be shown.

  6. Trade study for the disposition of cesium and strontium capsules

    International Nuclear Information System (INIS)

    Claghorn, R.D.

    1996-03-01

    This trade study analyzes alternatives for the eventual disposal of cesium and strontium capsules currently stored at the Waste Encapsulation and Storage Facility as by-product. However, for purposes of this study, it is assumed that at some time in the future, the capsules will be declared high-level waste and therefore will require disposal at an offsite geologic repository. The study considered numerous alternatives and selected three for detailed analysis: (1) overpack and storage at high-level waste canister storage building, (2) overpack at the high-level waste vitrification facility followed by storage at a high-level waste canister storage building, and (3) blend capsule contents with other high-level waste feed streams and vitrify at the high-level waste vitrification facility

  7. Sensitive Detection of Deliquescent Bacterial Capsules through Nanomechanical Analysis.

    Science.gov (United States)

    Nguyen, Song Ha; Webb, Hayden K

    2015-10-20

    Encapsulated bacteria usually exhibit strong resistance to a wide range of sterilization methods, and are often virulent. Early detection of encapsulation can be crucial in microbial pathology. This work demonstrates a fast and sensitive method for the detection of encapsulated bacterial cells. Nanoindentation force measurements were used to confirm the presence of deliquescent bacterial capsules surrounding bacterial cells. Force/distance approach curves contained characteristic linear-nonlinear-linear domains, indicating cocompression of the capsular layer and cell, indentation of the capsule, and compression of the cell alone. This is a sensitive method for the detection and verification of the encapsulation status of bacterial cells. Given that this method was successful in detecting the nanomechanical properties of two different layers of cell material, i.e. distinguishing between the capsule and the remainder of the cell, further development may potentially lead to the ability to analyze even thinner cellular layers, e.g. lipid bilayers.

  8. SrF2 capsule design for heat engine applications

    International Nuclear Information System (INIS)

    Lester, D.H.

    1976-04-01

    A number of design changes were considered to improve heat transfer characteristics of the WESF capsule. This capsule was evaluated in a design concept for use as a heat source in a helium-working fluid, Stirling heat engine. Throughout the study a heat block concept was used. The helium was assumed to be at 1200 0 F and 200 atm. The upper temperature limit at the fuel-metal interface was assumed to be 800 0 C because of material compatibility considerations. A 0.6-in. thick outer can was considered since it may be required for impact resistance and high pressure accident environments. The modifications considered were: (1) filling all gaps with helium rather than air, (2) filling gaps with powdered metal, and (3) adding a third can to the existing capsule. Also, enhancement of emissivity on metal surfaces was considered as a possible modification

  9. Small-Bowel Capsule Endoscopy in Patients with Suspected Crohn's Disease—Diagnostic Value and Complications

    Science.gov (United States)

    Figueiredo, Pedro; Almeida, Nuno; Lopes, Sandra; Duque, Gabriela; Freire, Paulo; Lérias, Clotilde; Gouveia, Hermano; Sofia, Carlos

    2010-01-01

    Background. The aim of this work was to assess the value of capsule enteroscopy in the diagnosis of patients with suspected Crohn's Disease (CD). Methods. This was a retrospective study in a single tertiary care centre involving patients undergoing capsule enteroscopy for suspected CD. Patients taking nonsteroidal anti inflammatory drugs during the thirty preceding days or with a follow-up period of less than six months were excluded. Results. Seventy eight patients were included. The endoscopic findings included mucosal breaks in 50%, ulcerated stenosis in 5%, and villous atrophy in 4%. The diagnosis of CD was established in 31 patients. The sensitivity, specificity, positive and negative predictive value of the endoscopic findings were 93%, 80%, 77%, and 94%, respectively. Capsule retention occurred in four patients (5%). The presence of ulcerated stenosis was significantly more frequent in patients with positive inflammatory markers. The diagnostic yield of capsule enteroscopy in patients with negative ileoscopy was 56%, with a diagnostic acuity of 93%. Conclusions. Small bowel capsule endoscopy is a safe and valid technique for assessing patients with suspected CD. Capsule retention is more frequent in patients with positive inflammatory markers. Patients with negative ileoscopy and suspected CD should be submitted to capsule enteroscopy. PMID:20811612

  10. Small-Bowel Capsule Endoscopy in Patients with Suspected Crohn's Disease—Diagnostic Value and Complications

    Directory of Open Access Journals (Sweden)

    Pedro Figueiredo

    2010-01-01

    Full Text Available Background. The aim of this work was to assess the value of capsule enteroscopy in the diagnosis of patients with suspected Crohn's Disease (CD. Methods. This was a retrospective study in a single tertiary care centre involving patients undergoing capsule enteroscopy for suspected CD. Patients taking nonsteroidal anti inflammatory drugs during the thirty preceding days or with a follow-up period of less than six months were excluded. Results. Seventy eight patients were included. The endoscopic findings included mucosal breaks in 50%, ulcerated stenosis in 5%, and villous atrophy in 4%. The diagnosis of CD was established in 31 patients. The sensitivity, specificity, positive and negative predictive value of the endoscopic findings were 93%, 80%, 77%, and 94%, respectively. Capsule retention occurred in four patients (5%. The presence of ulcerated stenosis was significantly more frequent in patients with positive inflammatory markers. The diagnostic yield of capsule enteroscopy in patients with negative ileoscopy was 56%, with a diagnostic acuity of 93%. Conclusions. Small bowel capsule endoscopy is a safe and valid technique for assessing patients with suspected CD. Capsule retention is more frequent in patients with positive inflammatory markers. Patients with negative ileoscopy and suspected CD should be submitted to capsule enteroscopy.

  11. Dr. Albert Carr--Science Educator 1930-2000

    Science.gov (United States)

    Lopez, Leslie

    2013-01-01

    The very first issue of "Educational Perspectives" was published in October of 1962. Dr. Albert Carr wrote one of the inaugural essays on the topic of current developments in science education, and he went on to write several other articles for the journal. This article shares why Dr. Albert Carr's colleagues remember him for his…

  12. A generalized scaling law for the ignition energy of inertial confinement fusion capsules

    International Nuclear Information System (INIS)

    Herrmann, M.C.

    2001-01-01

    The minimum energy needed to ignite an inertial confinement fusion capsule is of considerable interest in the optimization of an inertial fusion driver. Recent computational work investigating this minimum energy has found that it depends on the capsule implosion history, in particular, on the capsule drive pressure. This dependence is examined using a series of LASNEX simulations to find ignited capsules which have different values of the implosion velocity, fuel adiabat and drive pressure. It is found that the main effect of varying the drive pressure is to alter the stagnation of the capsule, changing its stagnation adiabat, which, in turn, affects the energy required for ignition. To account for this effect a generalized scaling law has been devised for the ignition energy, E ign ∝α if 1.88±0.05 υ -5.89±0.12 P -0.77±0.03 . This generalized scaling law agrees with the results of previous work in the appropriate limits. (author)

  13. Work plan for testing silicone impression material and fixture on pool cell capsule

    International Nuclear Information System (INIS)

    Lundeen, J.E.

    1994-01-01

    The purpose of this work plan is to provide a safe procedure to test a cesium capsule impression fixture at Waste Encapsulation and Storage Facility (WESF). The impression will be taken with silicone dental impression material pressed down upon the capsule using the impression fixture. This test will evaluate the performance of the fixture and impression material under high radiation and temperature conditions on a capsule in a WESF pool cell

  14. Additional effective dose by patients undergoing NAI-131 capsules therapy

    Energy Technology Data Exchange (ETDEWEB)

    Orlic, M.; Jovanovic, M.; Spasic Jokic, V.; Cuknic, O.; Ilic, Z.; Vranjes Djuric, S. [VINCA - Institute of Nuclear Sciences, Belgrade, Serbia and Montenegro (Yugoslavia)

    2006-07-01

    Capsules or solutions containing Na{sup 131}I are indicated for the therapy of some thyroid carcinomas such as functioning metastatic papillary or follicular carcinoma of the thyroid; and for the treatment of hyperthyroidism (diffuse toxic goiter and single or multiple toxic nodular goiter). The recommended dosage ranges of Na{sup 131}I capsules or solution for the therapy of the average patient (70 kg) are: (3.7-5.55) GBq for ablation of normal thyroid tissue; (3.7-7.4) GBq for subsequent treatments; a (148-370) MBq for hyperthyroidism. The purpose of this paper is to calculate effective dose as a result of iodine-131 capsules remaining in stomach before absorption starts. This result can determine the disadvantage of capsule versus solution containing sodium iodine-131 (Na{sup 131}I) in radionuclide therapy application from radiation protection point of view. The Monte Carlo code MCNP4b was used to model transport of gamma and beta particles emitted by radionuclide {sup 131}I treated as a point source at the bottom of stomach. Absorbed energy per unit transformation in stomach and surrounding organs has been calculated. (authors)

  15. Comparison of thyroid uptake of 131I capsule and solution in rabbits and graves disease patients

    International Nuclear Information System (INIS)

    Zhou Xinjian; Li Fang; Lu Jingqiao; Chen Daming; Zhang Ruilin

    2002-01-01

    Objective: To observe the difference between thyroid uptake rates (TUR) of 131 I capsule and solution in rabbits and Graves disease patients. Methods: Part one: 6 rabbits randomized into two groups received capsule or solution of 131 I 7.4 MBq. Then with SPECT scintigraphy 2,4,6 and 24 h thyroid pure counts in percentage of stomach counts (first frame) were determined. Part two: 1) Measured 131 I capsule standard. 2) 104 patients with Graves disease were administered tracing and therapeutic dose of 131 I capsule (capsule group), 118 of 131 I solution (solution group). Compared the tracing and therapeutic 131 I TUR at 24 h. Results: Part one: There were no significant difference at 2,4,6,24 h TUR between capsule and solution group. For 1 case the maximum TUR was at 6 h in capsule group and 2 cases in solution groups. Part two: 1) For the 131 I capsule administered immediately after being dissolved in 30 mL of water, the activity counts measured were higher by (13.8 +- 2.8)% than it was administered directly, t8.97, P 0.05) and in solution group were (71.3 +- 12.3)% and (65.1 +- 13.0)% (t = 3.82, P 131 I capsule standard should be dissolved before being measured. 3) 131 I capsules can be used as a standard formulation for Graves disease patients. 4) The dose of 131 I should be increased as tracer TUR is larger than 80.0%

  16. A Tribute to Dr. Willy Lens

    Directory of Open Access Journals (Sweden)

    Maarten Vansteenkiste

    2016-07-01

    Full Text Available Dr. Willy Lens, born on December 10th, 1943, passed away on August 29th, 2014. With his passing, the motivation community has lost a seminal member, a mentor, and a friend. Dr. Lens – a Fellow of the Association for Psychological Science and Founding Fellow of the American Educational Research Association – made fundamental contributions to the study of motivation both through his own work and through his caring and thoughtful mentorship of a large community of scholars. With this tribute, we want to honor Dr. Willy Lens’ significance to psychology and education as well as his positive influence, both personally and professionally, on the lives of dozens of scholars. With his contagious enthusiasm and caring mentorship, Willy was an example for our academic community and with this tribute we express our gratitude for the privilege to have collaborated with him.

  17. Ultrahigh speed en face OCT capsule for endoscopic imaging.

    Science.gov (United States)

    Liang, Kaicheng; Traverso, Giovanni; Lee, Hsiang-Chieh; Ahsen, Osman Oguz; Wang, Zhao; Potsaid, Benjamin; Giacomelli, Michael; Jayaraman, Vijaysekhar; Barman, Ross; Cable, Alex; Mashimo, Hiroshi; Langer, Robert; Fujimoto, James G

    2015-04-01

    Depth resolved and en face OCT visualization in vivo may have important clinical applications in endoscopy. We demonstrate a high speed, two-dimensional (2D) distal scanning capsule with a micromotor for fast rotary scanning and a pneumatic actuator for precision longitudinal scanning. Longitudinal position measurement and image registration were performed by optical tracking of the pneumatic scanner. The 2D scanning device enables high resolution imaging over a small field of view and is suitable for OCT as well as other scanning microscopies. Large field of view imaging for screening or surveillance applications can also be achieved by proximally pulling back or advancing the capsule while scanning the distal high-speed micromotor. Circumferential en face OCT was demonstrated in living swine at 250 Hz frame rate and 1 MHz A-scan rate using a MEMS tunable VCSEL light source at 1300 nm. Cross-sectional and en face OCT views of the upper and lower gastrointestinal tract were generated with precision distal pneumatic longitudinal actuation as well as proximal manual longitudinal actuation. These devices could enable clinical studies either as an adjunct to endoscopy, attached to an endoscope, or as a swallowed tethered capsule for non-endoscopic imaging without sedation. The combination of ultrahigh speed imaging and distal scanning capsule technology could enable both screening and surveillance applications.

  18. The Associated Absorption Features in Quasar Spectra of the Sloan Digital Sky Survey. I. Mg II Absorption Doublets

    Science.gov (United States)

    Chen, Zhi-Fu; Huang, Wei-Rong; Pang, Ting-Ting; Huang, Hong-Yan; Pan, Da-Sheng; Yao, Min; Nong, Wei-Jing; Lu, Mei-Mei

    2018-03-01

    Using the SDSS spectra of quasars included in the DR7Q or DR12Q catalogs, we search for Mg II λλ2796, 2803 narrow absorption doublets in the spectra data around Mg II λ2798 emission lines. We obtain 17,316 Mg II doublets, within the redshift range of 0.3299 ≤ z abs ≤ 2.5663. We find that a velocity offset of υ r 6000 km s‑1. If associated Mg II absorbers are defined by υ r present at least one associated Mg II system with {W}{{r}}λ 2796≥slant 0.2 \\mathringA . The fraction of associated Mg II systems with high-velocity outflows correlates with the average luminosities of their central quasars, indicating a relationship between outflows and the quasar feedback power. The υ r distribution of the outflow Mg II absorbers is peaked at 1023 km s‑1, which is smaller than the corresponding value of the outflow C IV absorbers. The redshift number density evolution of absorbers (dn/dz) limited by υ r > ‑3000 km s‑1 differs from that of absorbers constrained by υ r > 2000 km s‑1. Absorbers limited by υ r > 2000 km s‑1 and higher values exhibit profiles similar to dn/dz. In addition, the dn/dz is smaller when absorbers are constrained with larger υ r . The distributions of equivalent widths, and the ratio of {W}rλ 2796/{W}rλ 2803, are the same for associated and intervening systems, and independent of quasar luminosity.

  19. Thermal Analysis of a Dry Storage Concept for Capsule Dry Storage Project

    International Nuclear Information System (INIS)

    JOSEPHSON, W.S.

    2003-01-01

    There are 1,936 cesium (Cs) and strontium (Sr) capsules stored in pools at the Waste Encapsulation and Storage Facility (WESF). These capsules will be moved to dry storage on the Hanford Site as an interim measure to reduce risk. The Cs/Sr Capsule Dry Storage Project is conducted under the assumption that the capsules will eventually be moved to the repository at Yucca Mountain, and the design criteria include requirements that will facilitate acceptance at the repository. The storage system must also permit retrieval of capsules in the event that vitrification of the capsule contents is pursued. The Capsule Advisory Panel (CAP) was created by the Project Manager for the Hanford Site Capsule Dry Storage Project (CDSP). The purpose of the CAP is to provide specific technical input to the CDSP; to identify design requirements; to ensure design requirements for the project are conservative and defensible; to identify and resolve emerging, critical technical issues, as requested; and to support technical reviews performed by regulatory organizations, as requested. The CAP will develop supporting and summary documents that can be used as part of the technical and safety bases for the CDSP. The purpose of capsule dry storage thermal analysis is to: (1) Summarize the pertinent thermal design requirements sent to vendors, (2) Summarize and address the assumptions that underlie those design requirements, (3) Demonstrate that an acceptable design exists that satisfies the requirements, (4) Identify key design features and phenomena that promote or impede design success, (5) Support other CAP analyses such as corrosion and integrity evaluations, and (6) Support the assessment of proposed designs. It is not the purpose of this report to optimize or fully analyze variations of postulated acceptable designs. The present evaluation will indicate the impact of various possible design features, but not systematically pursue design improvements obtainable through analysis

  20. Drømmebilleder

    DEFF Research Database (Denmark)

    Fausing, Bent

    2014-01-01

    Bogen beskriver i en række intense analyser forbindelsen mellem ydre og indre billeder: altså mellem de moderne mediers billedverden og drømmens og erindringens indre billeder. I fokus for undersøgelsen er desuden kønnet, altså hvordan billeder viser, omformer eller skjuler kønnet, 'det andet', s...

  1. The position control of a capsule filled with magnetic fluid

    International Nuclear Information System (INIS)

    Rhee, E.J.; Park, M.K.; Yamane, R.; Oshima, S.

    2002-01-01

    In this paper, in order to establish the technique of a nozzle-flapper system of a servo valve using magnetic fluid in hydraulic system, a governing equation regarding the levitation of a capsule filled with magnetic fluid is formulated. Using PID control, an experiment for the position control of a capsule was performed. The experimental results were compared with the simulation results found by the governing equation

  2. Interventional microadhesiolysis: A new nonsurgical release technique for adhesive capsulitis of the shoulder

    Directory of Open Access Journals (Sweden)

    Lim Tae-Kyun

    2008-01-01

    Full Text Available Abstract Background A nonsurgical intervention, interventional microadhesiolysis, was developed to release adhesions in joints and soft tissues. This paper introduces the procedure and evaluates the efficacy of the intervention for adhesive capsulitis of the shoulder. Methods Ten patients (five men and five women with primary adhesive capsulitis of the shoulder were treated at a chronic pain management center in Korea. Three specially made needles are used in interventional microadhesiolysis: the Round, Flexed Round, and Ahn's needles. A Round Needle is inserted on the skin over middle of supraspinatus and advanced under the acromion and acromioclavicular joint (subacromial release. A Flexed Round Needle is inserted two-fingers caudal to the inferior border of the scapular spine and advanced over the capsule sliding on the surface of infraspinatus muscle-tendon fascia. The capsule is released while an assistant simultaneously passively abducts the shoulder to full abduction (posteroinferior capsule release. An Ahn's Needle is inserted on the skin over the lesser tubercle and advanced under the coracoid process sliding on the surface of the subscapularis muscle (subcoracoid release. Results After the patients underwent interventional microadhesiolysis, the self-rated pain score or severity declined significantly (p p Conclusion Our findings suggest that interventional microadhesiolysis is effective for managing adhesive capsulitis of the shoulder.

  3. Matrix polyelectrolyte capsules based on polysaccharide/MnCO₃ hybrid microparticle templates.

    Science.gov (United States)

    Wei, Qingrong; Ai, Hua; Gu, Zhongwei

    2011-06-15

    An efficient strategy for biomacromolecule encapsulation based on spontaneous deposition into polysaccharide matrix-containing capsules is introduced in this study. First, hybrid microparticles composed of manganese carbonate and ionic polysaccharides including sodium hyaluronate (HA), sodium alginate (SA) and dextran sulfate sodium (DS) with narrow size distribution were synthesized to provide monodisperse templates. Incorporation of polysaccharide into the hybrid templates was successful as verified by thermogravimetric analysis (TGA) and confocal laser scanning microscopy (CLSM). Matrix polyelectrolyte microcapsules were fabricated through layer-by-layer (LbL) self-assembly of oppositely charged polyelectrolytes (PEs) onto the hybrid particles, followed by removal of the inorganic part of the cores, leaving polysaccharide matrix inside the capsules. The loading and release properties of the matrix microcapsules were investigated using myoglobin as a model biomacromolecule. Compared to matrix-free capsules, the matrix capsules had a much higher loading capacity up to four times; the driving force is mostly due to electrostatic interactions between myoglobin and the polysaccharide matrix. From our observations, for the same kind of polysaccharide, a higher amount of polysaccharide inside the capsules usually led to better loading capacity. The release behavior of the loaded myoglobin could be readily controlled by altering the environmental pH. These matrix microcapsules may be used as efficient delivery systems for various charged water-soluble macromolecules with applications in biomedical fields. Copyright © 2010 Elsevier B.V. All rights reserved.

  4. Egg capsules of the dusky catshark Bythaelurus canescens (Carcharhiniformes, Scyliorhinidae) from the south-eastern Pacific Ocean.

    Science.gov (United States)

    Concha, F; Bustamante, C; Oddone, M C; Hernández, S; Lamilla, J

    2010-09-01

    The external morphology of the egg capsule of Bythaelurus canescens and its fixation to the substratum are described. Bythaelurus canescens egg capsules are typically vase-shaped, dorso-ventrally flattened, pale yellow in colour when fresh and covered by 12-15 longitudinal ridges. The anterior border of the capsule is straight, whereas the posterior border is semicircular. Two horns bearing long, coiled tendrils arise from the anterior and posterior ends of the capsule. The presence of longitudinal ridges and long coiled tendrils at both anterior and posterior ends of the capsule readily distinguish these egg capsules from those of other chondrichthyans occurring in the south-east Pacific Ocean. © 2010 The Authors. Journal compilation © 2010 The Fisheries Society of the British Isles.

  5. Structural analysis on the open basket type instrumented capsule for fuel irradiation tests in HANARO

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Do Sik; Kang, Y. H.; Kim, B. G.; Cho, M. S.; Sohn, J. M.; Choo, K. N.; Oh, J. M.; Shin, Y. T.; Park, S. J. [Korea Atomic Energy Research Institute, Taejeon (Korea)

    2002-05-01

    To develop the open basket type instrumented capsule to be used for the irradiation test of various nuclear fuels, it is necessary to ensure the compatibility of the capsule with HANARO and the structural integrity of the capsule. The dimensions of the open basket type instrumented capsule were determined in the basis of the pressure drop criteria in OR test hole of HANARO(mass flow rate <12.7kg/s, pressure drop {delta}P>200kPa). From the buckling stability analysis for this capsule, the critical buckling load P{sub cr} was 7.5kN. The vertical impact stress of the capsule under unit impact load was evaluated by the transient analysis, and the maximum vertical impact load calculated from the impact stress and the allowable stress was 60.5kN. Under the loading of the calculated Pcr, the maximum vertical impact stress was 20.4MPa. The structural integrity of the capsule under a horizontal impact loading was also examined. The mechanical stresses occurred by the pressure difference at the inner and outer surface of cladding and by the coolant pressure at the surface of cladding were 3.1MPa and 43.3MPa, respectively. These stress values were lower than the allowable stress in each case. Therefore, it was ensured that the instrumented capsule for the irradiation test of various nuclear fuels met the criteria on the structural integrity during installing and testing the capsule in HANARO. 8 refs., 61 figs., 3 tabs. (Author)

  6. Method and apparatus for dispensing small quantities of mercury from evacuated and sealed glass capsules

    Science.gov (United States)

    Grossman, Mark W.; George, William A.; Pai, Robert Y.

    1985-01-01

    A technique for opening an evacuated and sealed glass capsule containing a material that is to be dispensed which has a relatively high vapor pressure such as mercury. The capsule is typically disposed in a discharge tube envelope. The technique involves the use of a first light source imaged along the capsule and a second light source imaged across the capsule substantially transversely to the imaging of the first light source. Means are provided for constraining a segment of the capsule along its length with the constraining means being positioned to correspond with the imaging of the second light source. These light sources are preferably incandescent projection lamps. The constraining means is preferably a multiple looped wire support.

  7. Capsule Typing of Haemophilus influenzae by Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry.

    Science.gov (United States)

    Månsson, Viktor; Gilsdorf, Janet R; Kahlmeter, Gunnar; Kilian, Mogens; Kroll, J Simon; Riesbeck, Kristian; Resman, Fredrik

    2018-03-01

    Encapsulated Haemophilus influenzae strains belong to type-specific genetic lineages. Reliable capsule typing requires PCR, but a more efficient method would be useful. We evaluated capsule typing by using matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry. Isolates of all capsule types (a-f and nontypeable; n = 258) and isogenic capsule transformants (types a-d) were investigated. Principal component and biomarker analyses of mass spectra showed clustering, and mass peaks correlated with capsule type-specific genetic lineages. We used 31 selected isolates to construct a capsule typing database. Validation with the remaining isolates (n = 227) showed 100% sensitivity and 92.2% specificity for encapsulated strains (a-f; n = 61). Blinded validation of a supplemented database (n = 50) using clinical isolates (n = 126) showed 100% sensitivity and 100% specificity for encapsulated strains (b, e, and f; n = 28). MALDI-TOF mass spectrometry is an accurate method for capsule typing of H. influenzae.

  8. Physics of ignition for ICF capsules

    International Nuclear Information System (INIS)

    Lindl, J.D.

    1989-01-01

    The implosion of an ICF capsule must accomplish both compression of the main fuel to several hundred grams per cubic centimeter and heating and compression of the central region of the fuel to ignition. This report discusses the physics of these conditions

  9. Profile Interview: Dr. Patrick Dongosolo Kamalo – Consultant ...

    African Journals Online (AJOL)

    Dr. Yohane Gadama (YG), an MMJ intern, interviews Dr. Patrick Dongosolo Kamalo (PDK) on his work as Malawi's only local practicing neurosurgeon, the launch of Blantyre Institute of Neurological Sciences (BINS) and the beginning of Neurosurgery training in Malawi ...

  10. Radiation research of materials using irradiation capsules

    International Nuclear Information System (INIS)

    Chamrad, B.

    1976-01-01

    The methods are briefly characterized of radiation experiments on the WWR-S research reactor. The irradiation capsule installed in the reactor including the electronic instrumentation is described. Irradiated samples temperature is stabilized by an auxiliary heat source placed in the irradiation space. The electronic control equipment of the system is automated. In irradiation experiments, experimental and operating conditions are recorded by a digital measuring centre with electric typewriter and paper tape data recording and by an analog compensating recorder. The irradiation experiment control system controls irradiated sample temperature, the supply current size and the heating element temperature of the auxiliary stabilizing source, inert and technological pressures of the capsule atmosphere and the thermostat temperature of the thermocouple junctions. (O.K.)

  11. Mishra, Dr A C

    Indian Academy of Sciences (India)

    Elected: 2009 Section: Medicine. Mishra, Dr A C . Ph.D. (Pune), FNA. Date of birth: 1 July 1950. Specialization: Human Viral Infection & Zoonotic Diseases, Public Health Address: Director, Interactive Research School of Health Affairs, Bharati Vidyapeeth University, ...

  12. Thiagarajan, Dr Pazhamaneri Subramaniam

    Indian Academy of Sciences (India)

    Elected: 1995 Section: Mathematical Sciences. Thiagarajan, Dr Pazhamaneri Subramaniam Ph.D. (Rice), FNASc. Date of birth: 9 November 1948. Specialization: Distributed Probabilistic Systems, Hybrid Systems and Computational Systems Biology Address: Laboratory of System Pharmacology, Harvard Medical School, ...

  13. Review of safety issues that pertain to the use of WESF cesium chloride capsules in an irradiator

    International Nuclear Information System (INIS)

    Tingey, G.L.; Wheelwright, E.J.; Lytle, J.M.

    1984-07-01

    Since the recovery of the fission product cesium-137 began in 1967, about 1500 capsules, each containing an average of about 50,000 curies of cesium chloride, have been produced. These capsules were designed to safely store this gamma-emitting fission product, but they are now considered to be a valuable source for irradiators. The capsules were designed to have a large margin of safety in their mechanical properties. Impact, percussion, and thermal tests have been conducted that demonstrate their ability to meet anticipated licensing requirements. Although this document is not intended to develop or evaluate accident scenarios, an examination of the effects of heating a capsule to 800 0 C for up to 90 min was completed. At 800 0 C, the salt volume would be expected to exceed the initial capsule volume in a few (up to 1/3) of the WESF capsules. Under these conditions, the inner capsule would expand to accommodate the salt volume and the gas pressure. The strength and ductility of the capsule are more than adequate to permit this expansion with a safety margin of at least a factor of three. Capsules have now been stored in the WESF pool for 10 years, and 15 capsules have been used in the Sandia Irradiator for Dried Sewage Solids facility for nearly 5 years without any capsule failure. This experience, along with available laboratory and production data, gives reasonable assurance that the capsules can be safely used in properly designed commercial irradiators. This is especially the case when one considers current and future evaluation programs designed to assess the long-term effects of corrosion and mechanical properties degradation

  14. Fabrication, characterization and evaluation of bacterial cellulose-based capsule shells for oral drug delivery

    DEFF Research Database (Denmark)

    Ullah, Hanif; Badshah, Munair; Mäkilä, Ermei

    2017-01-01

    Bacterial cellulose (BC) was investigated for the first time for the preparation of capsule shells for immediate and sustained release of drugs. The prepared capsule shells were characterized using X-ray diffraction, scanning electron microscopy and Fourier transform infrared spectroscopy. The BC...... to gelatin capsules with both immediate and sustained drug release properties depending upon the compositions of the encapsulated materials....

  15. A study for the development of the capsule assembly machine for the re-irradiation test

    International Nuclear Information System (INIS)

    Kang, Y. H.; Kim, J. K.; Yeom, K. Y.; Yoon, K. B.; Choi, M. H.; Kim, B. K.

    2004-01-01

    A series of in-pile tests are being carried out to support the advanced fuel development programs at the HANARO reactor. There are still some limitations for satisfying the test requirements. To meet the demands for the high burnup test at HANARO, new capsule assembling technology is required. This paper describes the design requirements, design and fabrication of the mockup, and pre-operational tests performed for the development of the new capsule assembly machine. The mockup manufactured consists of a base plate, a capsule stand, a capsule guide pipe and clamping device and is 1m in outer diameter, 1.8m in height and 136kg in weight. From the pre-operation tests, the optimum clamping torque was 450kgf·cm for preventing rotation and shaking of the capsule main body during assembling capsule main body and protection tube, and this remote assembling procedure can be applicable to the high burnup test

  16. Summary of the irradiation history of the TRIST-ER1 capsule

    Energy Technology Data Exchange (ETDEWEB)

    Qualls, A.L.; Eatherly, W.S.; Heatherly, D.W. [Oak Ridge National Lab., TN (United States)

    1996-10-01

    The TRIST-ERI capsule was assembled and irradiated in a large Removable Beryllium (RB{star}) position of the High Flux Isotope Reactor (HFIR) during this reporting period. Irradiation began on March 8, 1996, was completed on June 20, 1996, during operating cycles 344, 345, and 346. This report describes the thermal operation of the capsule.

  17. Association between HLA-DR antigens and rheumatoid arthritis in Arabs.

    OpenAIRE

    Sattar, M A; al-Saffar, M; Guindi, R T; Sugathan, T N; Behbehani, K

    1990-01-01

    Eighty five Arab patients with classical and definite rheumatoid arthritis were typed to determine the prevalence of HLA A, B, C, and DR antigens. A significant increase in the prevalence of HLA-A10, B8, B21, and DR3 was found in comparison with a control population matched for age and sex. HLA-DR5 was significantly decreased in the patient group. The classical association of HLA-DR4 with rheumatoid arthritis could not be confirmed in the Arab patients resident in Kuwait, supporting reported ...

  18. The design, fabrication, and testing of beryllium capsules for resonant ultrasound experiments

    International Nuclear Information System (INIS)

    Salazar, M.A.; Salzer, L.; Day, R.

    1999-01-01

    Inertial Confinement Fusion (ICF) ignition targets require smooth and well-characterized deuterium/tritium (DT) ice layers. Los Alamos is developing Resonant Ultrasound Spectroscopy (RUS) to measure the internal pressure in the targets at room temperature after filling with DT. RUS techniques also can detect and measure the amplitudes of low modal surface roughness perturbations of the target shell interior. The experiments required beryllium capsules with a nominal inside radius of 1 mm and a spherical outside radius of 3 mm. The capsules have various spherical harmonic contours up to mode 12 machined into their interior surfaces. The capsules are constructed from hemispheres using an epoxy adhesive and then filled to ∼270 atm with helium or deuterium gas. This paper describes the adhesive joint design, machining techniques, and interior geometry inspection techniques. It also describes the fixtures needed to assemble, fill, and pressure test the capsules

  19. Budhani, Dr Ramesh Chandra

    Indian Academy of Sciences (India)

    Budhani, Dr Ramesh Chandra Ph.D. (IIT, Delhi), FNASc, FNA. Date of birth: 3 February 1955. Specialization: Renewable Energy, Nanoscale Systems, Experimental Condensed Matter Physics, Superconductivity and Magnetism Address: Department of Physics, Lasers & Photonics, Indian Institute of Technology, Kanpur 208 ...

  20. Salunke, Dr Dinakar Mashnu

    Indian Academy of Sciences (India)

    Fellow Profile. Elected: 2001 Section: General Biology. Salunke, Dr Dinakar Mashnu Ph.D. (IISc), FNASc, FNA, FTWAS. Date of birth: 1 July 1955. Specialization: Structural Biology, Macromolecular Crystallography and Immunology Address: Director, International Centre for Genetic Engineering, & Biotechnology, Aruna Asaf ...

  1. Watve, Dr Milind Gajanan

    Indian Academy of Sciences (India)

    Date of birth: 12 December 1957. Specialization: Wildlife Ecology & Animal Cognition, Evolutionary Biology, Computational Biology and Microbial Diversity Address: Professor, Biology, Indian Institute of Science Education & Research, Dr Homi Bhabha Road, Pashan, Pune 411 008, Maharashtra Contact: Office: (020) 2590 ...

  2. Shivanna, Dr Kundaranahalli Ramalingaiah

    Indian Academy of Sciences (India)

    Elected: 1985 Section: Plant Sciences. Shivanna, Dr Kundaranahalli Ramalingaiah Ph.D. (Delhi), FNA, FNAAS, FNASc. Date of birth: 30 June 1940. Specialization: Pollen Biology, Reproductive Ecology and Conservation Biology Address: Odekar Farms, Nandihalli, via Thovinakere, Tumkur 572 138, Karnataka Contact:

  3. Gaia DR1 documentation

    Science.gov (United States)

    van Leeuwen, F.; de Bruijne, J. H. J.; Arenou, F.; Comoretto, G.; Eyer, L.; Farras Casas, M.; Hambly, N.; Hobbs, D.; Salgado, J.; Utrilla Molina, E.; Vogt, S.; van Leeuwen, M.; Abreu, A.; Altmann, M.; Andrei, A.; Babusiaux, C.; Bastian, U.; Biermann, M.; Blanco-Cuaresma, S.; Bombrun, A.; Borrachero, R.; Brown, A. G. A.; Busonero, D.; Busso, G.; Butkevich, A.; Cantat-Gaudin, T.; Carrasco, J. M.; Castañeda, J.; Charnas, J.; Cheek, N.; Clementini, G.; Crowley, C.; Cuypers, J.; Davidson, M.; De Angeli, F.; De Ridder, J.; Evans, D.; Fabricius, C.; Findeisen, K.; Fleitas, J. M.; Gracia, G.; Guerra, R.; Guy, L.; Helmi, A.; Hernandez, J.; Holl, B.; Hutton, A.; Klioner, S.; Lammers, U.; Lecoeur-Taïbi, I.; Lindegren, L.; Luri, X.; Marinoni, S.; Marrese, P.; Messineo, R.; Michalik, D.; Mignard, F.; Montegriffo, P.; Mora, A.; Mowlavi, N.; Nienartowicz, K.; Pancino, E.; Panem, C.; Portell, J.; Rimoldini, L.; Riva, A.; Robin, A.; Siddiqui, H.; Smart, R.; Sordo, R.; Soria, S.; Turon, C.; Vallenari, A.; Voss, H.

    2017-12-01

    We present the first Gaia data release, Gaia DR1, consisting of astrometry and photometry for over 1 billion sources brighter than magnitude 20.7 in the white-light photometric band G of Gaia. The Gaia Data Processing and Analysis Consortium (DPAC) processed the raw measurements collected with the Gaia instruments during the first 14 months of the mission, and turned these into an astrometric and photometric catalogue. Gaia DR1 consists of three parts: an astrometric data set which contains the positions, parallaxes, and mean proper motions for about 2 million of the brightest stars in common with the Hipparcos and Tycho-2 catalogues (the primary astrometric data set) and the positions for an additional 1.1 billion sources (the secondary astrometric data set). The primary set forms the realisation of the Tycho-Gaia Astrometric Solution (TGAS). The second part of Gaia DR1 is the photometric data set, which contains the mean G-band magnitudes for all sources. The third part consists of the G-band light curves and the characteristics of 3000 Cepheid and RR Lyrae stars observed at high cadence around the south ecliptic pole. The positions and proper motions in the astrometric data set are given in a reference frame that is aligned with the International Celestial Reference Frame (ICRF) to better than 0.1 mas at epoch J2015.0, and non-rotating with respect to the ICRF to within 0.03 mas yr^-1. For the primary astrometric data set, the typical standard error for the positions and parallaxes is about 0.3 mas, while for the proper motions the typical standard error is about 1 mas yr^-1. Whereas it has been suggested in Gaia Collaboration et al. (2016a) that a systematic component of ∼0.3 mas should be 'added' (in quadrature) to the parallax uncertainties, Brown (2017) clarifies that reported parallax standard errors already include local systematics as a result of the calibration of the TGAS parallax uncertainties by comparison to Hipparcos parallaxes. For the subset of

  4. An Automated Self-Learning Quantification System to Identify Visible Areas in Capsule Endoscopy Images.

    Science.gov (United States)

    Hashimoto, Shinichi; Ogihara, Hiroyuki; Suenaga, Masato; Fujita, Yusuke; Terai, Shuji; Hamamoto, Yoshihiko; Sakaida, Isao

    2017-08-01

    Visibility in capsule endoscopic images is presently evaluated through intermittent analysis of frames selected by a physician. It is thus subjective and not quantitative. A method to automatically quantify the visibility on capsule endoscopic images has not been reported. Generally, when designing automated image recognition programs, physicians must provide a training image; this process is called supervised learning. We aimed to develop a novel automated self-learning quantification system to identify visible areas on capsule endoscopic images. The technique was developed using 200 capsule endoscopic images retrospectively selected from each of three patients. The rate of detection of visible areas on capsule endoscopic images between a supervised learning program, using training images labeled by a physician, and our novel automated self-learning program, using unlabeled training images without intervention by a physician, was compared. The rate of detection of visible areas was equivalent for the supervised learning program and for our automatic self-learning program. The visible areas automatically identified by self-learning program correlated to the areas identified by an experienced physician. We developed a novel self-learning automated program to identify visible areas in capsule endoscopic images.

  5. Semipermeable Capsules Wrapping a Multifunctional and Self-regulated Co-culture Microenvironment for Osteogenic Differentiation

    Science.gov (United States)

    Correia, Clara R.; Pirraco, Rogério P.; Cerqueira, Mariana T.; Marques, Alexandra P.; Reis, Rui L.; Mano, João F.

    2016-02-01

    A new concept of semipermeable reservoirs containing co-cultures of cells and supporting microparticles is presented, inspired by the multi-phenotypic cellular environment of bone. Based on the deconstruction of the “stem cell niche”, the developed capsules are designed to drive a self-regulated osteogenesis. PLLA microparticles functionalized with collagen I, and a co-culture of adipose stem (ASCs) and endothelial (ECs) cells are immobilized in spherical liquified capsules. The capsules are coated with multilayers of poly(L-lysine), alginate, and chitosan nano-assembled through layer-by-layer. Capsules encapsulating ASCs alone or in a co-culture with ECs are cultured in endothelial medium with or without osteogenic differentiation factors. Results show that osteogenesis is enhanced by the co-encapsulation, which occurs even in the absence of differentiation factors. These findings are supported by an increased ALP activity and matrix mineralization, osteopontin detection, and the up regulation of BMP-2, RUNX2 and BSP. The liquified co-capsules also act as a VEGF and BMP-2 cytokines release system. The proposed liquified capsules might be a valuable injectable self-regulated system for bone regeneration employing highly translational cell sources.

  6. Strong Dependence of Hydration State of F-Actin on the Bound Mg(2+)/Ca(2+) Ions.

    Science.gov (United States)

    Suzuki, Makoto; Imao, Asato; Mogami, George; Chishima, Ryotaro; Watanabe, Takahiro; Yamaguchi, Takaya; Morimoto, Nobuyuki; Wazawa, Tetsuichi

    2016-07-21

    Understanding of the hydration state is an important issue in the chemomechanical energetics of versatile biological functions of polymerized actin (F-actin). In this study, hydration-state differences of F-actin by the bound divalent cations are revealed through precision microwave dielectric relaxation (DR) spectroscopy. G- and F-actin in Ca- and Mg-containing buffer solutions exhibit dual hydration components comprising restrained water with DR frequency f2 (fw). The hydration state of F-actin is strongly dependent on the ionic composition. In every buffer tested, the HMW signal Dhyme (≡ (f1 - fw)δ1/(fwδw)) of F-actin is stronger than that of G-actin, where δw is DR-amplitude of bulk solvent and δ1 is that of HMW in a fixed-volume ellipsoid containing an F-actin and surrounding water in solution. Dhyme value of F-actin in Ca2.0-buffer (containing 2 mM Ca(2+)) is markedly higher than in Mg2.0-buffer (containing 2 mM Mg(2+)). Moreover, in the presence of 2 mM Mg(2+), the hydration state of F-actin is changed by adding a small fraction of Ca(2+) (∼0.1 mM) and becomes closer to that of the Ca-bound form in Ca2.0-buffer. This is consistent with the results of the partial specific volume and the Cotton effect around 290 nm in the CD spectra, indicating a change in the tertiary structure and less apparent change in the secondary structure of actin. The number of restrained water molecules per actin (N2) is estimated to be 1600-2100 for Ca2.0- and F-buffer and ∼2500 for Mg2.0-buffer at 10-15 °C. These numbers are comparable to those estimated from the available F-actin atomic structures as in the first water layer. The number of HMW molecules is roughly explained by the volume between the equipotential surface of -kT/2e and the first water layer of the actin surface by solving the Poisson-Boltzmann equation using UCSF Chimera.

  7. Safety evaluation for packaging for 1720-DR sodium-filled tank

    International Nuclear Information System (INIS)

    Mercado, M.S.

    1996-01-01

    Preparations are under way to sell the sodium stored in the 1720-DR tank in the 1720-DR building. This will require that the tank, as well as the 1720-DR facility, be moved to the 300 Area, so that the sodium may be melted and transferred into a railroad tanker car. Because the sodium is a hazardous material and is being shipped in a nonspecification packaging, a safety evaluation for packaging (SEP) is required. This SEP approves the sodium-filled tank for a single shipment from the 105-DR area to the 300 Area

  8. The Poly-γ-D-Glutamic Acid Capsule of Bacillus licheniformis, a Surrogate of Bacillus anthracis Capsule Induces Interferon-Gamma Production in NK Cells through Interactions with Macrophages.

    Science.gov (United States)

    Lee, Hae-Ri; Jeon, Jun Ho; Rhie, Gi-Eun

    2017-05-28

    The poly-γ- D -glutamic acid (PGA) capsule, a major virulence factor of Bacillus anthracis , provides protection of the bacterium from phagocytosis and allows its unimpeded growth in the host. We investigated crosstalk between murine natural killer (NK) cells and macrophages stimulated with the PGA capsule of Bacillus licheniformis , a surrogate of the B. anthracis capsule. PGA induced interferon-gamma production from NK cells cultured with macrophages. This effect was dependent on macrophage-derived IL-12 and cell-cell contact interaction with macrophages through NK cell receptor NKG2D and its ligand RAE-1. The results showed that PGA could enhance NK cell activation by inducing IL-12 production in macrophages and a contact-dependent crosstalk with macrophages.

  9. The effects of convergence ratio on the implosion behavior of DT layered inertial confinement fusion capsules

    Science.gov (United States)

    Haines, Brian M.; Yi, S. A.; Olson, R. E.; Khan, S. F.; Kyrala, G. A.; Zylstra, A. B.; Bradley, P. A.; Peterson, R. R.; Kline, J. L.; Leeper, R. J.; Shah, R. C.

    2017-07-01

    The wetted foam capsule design for inertial confinement fusion capsules, which includes a foam layer wetted with deuterium-tritium liquid, enables layered capsule implosions with a wide range of hot-spot convergence ratios (CR) on the National Ignition Facility. We present a full-scale wetted foam capsule design that demonstrates high gain in one-dimensional simulations. In these simulations, increasing the convergence ratio leads to an improved capsule yield due to higher hot-spot temperatures and increased fuel areal density. High-resolution two-dimensional simulations of this design are presented with detailed and well resolved models for the capsule fill tube, support tent, surface roughness, and predicted asymmetries in the x-ray drive. Our modeling of these asymmetries is validated by comparisons with available experimental data. In 2D simulations of the full-scale wetted foam capsule design, jetting caused by the fill tube is prevented by the expansion of the tungsten-doped shell layer due to preheat. While the impacts of surface roughness and predicted asymmetries in the x-ray drive are enhanced by convergence effects, likely underpredicted in 2D at high CR, simulations predict that the capsule is robust to these features. Nevertheless, the design is highly susceptible to the effects of the capsule support tent, which negates all of the one-dimensional benefits of increasing the convergence ratio. Indeed, when the support tent is included in simulations, the yield decreases as the convergence ratio is increased for CR > 20. Nevertheless, the results suggest that the full-scale wetted foam design has the potential to outperform ice layer capsules given currently achievable levels of asymmetries when fielded at low convergence ratios (CR < 20).

  10. Design and manufacturing of non-instrumented capsule for advanced PWR fuel pellet irradiation test in HANARO

    Energy Technology Data Exchange (ETDEWEB)

    Kim, D. H.; Lee, C. B.; Song, K. W. [Korea Atomic Energy Research Institute, Taejeon (Korea)

    2002-04-01

    This project is preparing to irradiation test of the developed large grain UO{sub 2} fuel pellet in HANARO for pursuit fuel safety and high burn-up in 'Advanced LWR Fuel Technology Development Project' as a part Nuclear Mid and Long-term R and D Program. On the basis test rod is performed the nuclei property and preliminary fuel performance analysis, test rod and non-instrumented capsule are designed and manufactured for irradiation test in HANARO. This non-instrumented irradiation capsule of Advanced PWR Fuel pellet was referred the non-instrumented capsule for an irradiation test of simulated DUPIC fuel in HANARO(DUPIC Rig-001) and 18-element HANARO fuel, was designed to ensure the integrity and the endurance of non-instrumented capsule during the long term(2.5 years) irradiation. To irradiate the UO{sub 2} pellets up to the burn-up 70 MWD/kgU, need the time about 60 months and ensure the integrity of non-instrumented capsule for 30 months until replace the new capsule. This non-instrumented irradiation capsule will be based to develope the non-instrumented capsule for the more long term irradiation in HANARO. 22 refs., 13 figs., 5 tabs. (Author)

  11. Impacts of Implosion Asymmetry And Hot Spot Shape On Ignition Capsules

    Science.gov (United States)

    Cheng, Baolian; Kwan, Thomas J. T.; Wang, Yi-Ming; Yi, S. Austin; Batha, Steve

    2017-10-01

    Implosion symmetry plays a critical role in achieving high areal density and internal energy at stagnation during hot spot formation in ICF capsules. Asymmetry causes hot spot irregularity and stagnation de-synchronization that results in lower temperatures and areal densities of the hot fuel. These degradations significantly affect the alpha heating process in the DT fuel as well as on the thermonuclear performance of the capsules. In this work, we explore the physical factors determining the shape of the hot spot late in the implosion and the effects of shape on Î+/-particle transport. We extend our ignition theory [1-4] to include the hot spot shape and quantify the effects of the implosion asymmetry on both the ignition criterion and capsule performance. We validate our theory with the NIF existing experimental data Our theory shows that the ignition criterion becomes more restrictive with the deformation of the hot spot. Through comparison with the NIF data, we demonstrate that the shape effects on the capsules' performance become more explicit as the self-heating and yield of the capsules increases. The degradation of the thermonuclear burn by the hot spot shape for high yield shots to date can be as high as 20%. Our theory is in good agreement with the NIF data. This work was performed under the auspices of the U.S. Department of Energy by the Los Alamos National Laboratory under Contract No. W-7405-ENG-36.

  12. RbsR Activates Capsule but Represses the rbsUDK Operon in Staphylococcus aureus.

    Science.gov (United States)

    Lei, Mei G; Lee, Chia Y

    2015-12-01

    Staphylococcus aureus capsule is an important virulence factor that is regulated by a large number of regulators. Capsule genes are expressed from a major promoter upstream of the cap operon. A 10-bp inverted repeat (IR) located 13 bp upstream of the -35 region of the promoter was previously shown to affect capsule gene transcription. However, little is known about transcriptional activation of the cap promoter. To search for potential proteins which directly interact with the cap promoter region (Pcap), we directly analyzed the proteins interacting with the Pcap DNA fragment from shifted gel bands identified by electrophoretic mobility shift assay. One of these regulators, RbsR, was further characterized and found to positively regulate cap gene expression by specifically binding to the cap promoter region. Footprinting analyses showed that RbsR protected a DNA region encompassing the 10-bp IR. Our results further showed that rbsR was directly controlled by SigB and that RbsR was a repressor of the rbsUDK operon, involved in ribose uptake and phosphorylation. The repression of rbsUDK by RbsR could be derepressed by D-ribose. However, D-ribose did not affect RbsR activation of capsule. Staphylococcus aureus is an important human pathogen which produces a large number of virulence factors. We have been using capsule as a model virulence factor to study virulence regulation. Although many capsule regulators have been identified, the mechanism of regulation of most of these regulators is unknown. We show here that RbsR activates capsule by direct promoter binding and that SigB is required for the expression of rbsR. These results define a new pathway wherein SigB activates capsule through RbsR. Our results further demonstrate that RbsR inhibits the rbs operon involved in ribose utilization, thereby providing an example of coregulation of metabolism and virulence in S. aureus. Thus, this study further advances our understanding of staphylococcal virulence regulation

  13. Chandrashekar, Dr Tavarekere Kalliah

    Indian Academy of Sciences (India)

    Fellow Profile. Elected: 2000 Section: Chemistry. Chandrashekar, Dr Tavarekere Kalliah Ph.D. (IISc), FNASc, FNA, FTWAS Council Service: 2013-15. Date of birth: 1 January 1956. Specialization: Bio-inorganic Chemistry, Synthetic Inorganic Chemistry and Catalysis Address: Senior Professor, School of Chemical Sciences, ...

  14. Majumdar, Dr Subeer Suhash

    Indian Academy of Sciences (India)

    Fellow Profile. Elected: 2014 Section: Animal Sciences. Majumdar, Dr Subeer Suhash Ph.D. (nagpur), FNA, FNASc. Date of birth: 21 May 1961. Specialization: Animal Biotechnology, Transgenic Animals, Endocrinology Address: Director, National Institute of Animal Biotechnology, Gopan Pally, Hyderabad 500 046, A.P.

  15. Gupta, Dr Chhitar Mal

    Indian Academy of Sciences (India)

    Gupta, Dr Chhitar Mal Ph.D. (Agra), FNA, FNASc, FAMS, FTWAS Council Service: 1998-2000. Date of birth: 1 September 1944. Specialization: Membrane Biology, Bio-organic Chemistry and Molecular Biophysics Address: Distinguished Professor and Infosys Chair, Institute of Bioinformatics & Applied Biotechnology, Room ...

  16. Babu, Dr Cherukuri Raghavendra

    Indian Academy of Sciences (India)

    Fellow Profile. Elected: 1990 Section: Plant Sciences. Babu, Dr Cherukuri Raghavendra D.Phil. (Calcutta). Date of birth: 30 June 1940. Specialization: Biosystematics, Ecology and Population Genetics Address: Professor Emeritus, CEMDE, School of Environmental Studies, University of Delhi, Delhi 110 007, U.T.. Contact:

  17. Anil, Dr Arga Chandrashekar

    Indian Academy of Sciences (India)

    Home; Fellowship. Fellow Profile. Elected: 2015 Section: Earth & Planetary Sciences. Anil, Dr Arga Chandrashekar Ph.D. (Karnatak). Date of birth: 23 January 1959. Specialization: Biological Oceanography, Marine Ecology, Marine Biology Address: Chief Scientist, National Institute of Oceanography, Dona Paula 403 004, ...

  18. Sharma, Dr Ram Swaroop

    Indian Academy of Sciences (India)

    Home; Fellowship. Fellow Profile. Elected: 1989 Section: Earth & Planetary Sciences. Sharma, Dr Ram Swaroop Ph.D. (Basel), FNA. Date of birth: 10 July 1937. Specialization: Metamorphic Petrology, Mineralogy and Precambrian Geology Address: 70/36, Pratapnagar, Sector 7, Sanganer (RHB), Jaipur 302 033, Rajasthan

  19. Dr Satish R. Shetye

    Indian Academy of Sciences (India)

    Elected: 1992 Section: Earth & Planetary Sciences. Shetye, Dr Satish Ramnath Ph.D. (Washington), FNA, FNASc. Council Service: 1998-2003. Date of birth: 25 October 1950. Specialization: Physical Oceanography Address: Vice Chancellor, Goa University, Taleigao Plateau 403 206, Goa Contact: Office: (0832) 651 9001

  20. Jena, Dr Prafulla Kumar

    Indian Academy of Sciences (India)

    Jena, Dr Prafulla Kumar Ph.D. (Utkal). Date of birth: 27 December 1931. Specialization: Extractive Metallurgy, Mineral Processing, Environmental Engineering and Materials Processing Address: Chairman, Institute of Advance Technology and Environmental Studies, 80A-831A Lewis Road, Bhubaneswar 751 002, Orissa

  1. Kulkarni, Dr Mohan Gopalkrishna

    Indian Academy of Sciences (India)

    Elected: 1996 Section: Engineering & Technology. Kulkarni, Dr Mohan Gopalkrishna Ph.D. (Mumbai), FNAE. Date of birth: 14 November 1950. Specialization: Polymer Science & Engineering, Intellectual Property Address: Emeritus Scientist, Unit for R&D of Information Products, Tapovan, NCL Campus, Pashan Road, Pune ...

  2. Apte, Dr Shree Kumar

    Indian Academy of Sciences (India)

    Elected: 2008 Section: General Biology. Apte, Dr Shree Kumar Ph.D. (Gujarat), FNA, FNASc, FNAAS. Date of birth: 18 October 1952. Specialization: Molecular Biology & Biotechnology, Physiology and Stress Biology of Bacteria & Plants Address: Emeritus Professor, Homi Bhabha National Institute, Anushakti Nagar, ...

  3. AN ELECTROMAGNETIC PNEUMO CAPSULE SYSTEM FOR CONVEYING MINERALS AND MINE WASTES

    Energy Technology Data Exchange (ETDEWEB)

    Henry Liu; Charles W. Lenau

    2005-03-01

    The purpose of this project is to investigate the technical and economic feasibility of using a new and advanced pneumatic capsule pipeline (PCP) system for transporting minerals and mine wastes. The new system is different from conventional PCPs in two main respects: (1) it uses linear induction motors (LIMs) instead of blowers (fans) at the inlet of the pipeline to drive (pump) the capsules and the air through the pipeline; and (2) the capsules in the PCP have steel wheels running on steel rails as opposed to capsules in conventional systems, which use wheels with rubber tires running inside a pipe without rail. The advantage of using LIM pump instead of blower is that the former is non-intrusive and hence does not block the passage of capsules, enabling the system to run continuously without having to make the capsules bypass the pump. This not only simplifies the system but also enables the system to achieve much larger cargo throughput than that of PCPs using blowers, and use of LIMs as booster pumps which enables the system to have any length or to be used for transporting cargoes over practically any distance, say even one thousand kilometers or miles. An advantage of using steel wheels rolling on steel rails instead of using rubber tires rolling inside a pipeline is that the rolling friction coefficient and hence the use of energy is greatly reduced from that of conventional PCP systems. Moreover, rails enable easy control of capsule motion, such as switching capsules to a branch line by using railroad switching equipment. The advanced PCP system studied under this project uses rectangular conduits instead of circular pipe, having cross-sectional areas of 1 m by 1 m approximately. The system can be used for various transportation distances, and it can transport up to 50 million tonnes (metric tons) of cargo annually--the throughput of the largest mines in the world. Both an aboveground and an underground system were investigated and compared. The technical

  4. Biomechanical Effects of Acromioplasty on Superior Capsule Reconstruction for Irreparable Supraspinatus Tendon Tears.

    Science.gov (United States)

    Mihata, Teruhisa; McGarry, Michelle H; Kahn, Timothy; Goldberg, Iliya; Neo, Masashi; Lee, Thay Q

    2016-01-01

    Acromioplasty is increasingly being performed for both reparable and irreparable rotator cuff tears. However, acromioplasty may destroy the coracoacromial arch, including the coracoacromial ligament, consequently causing a deterioration in superior stability even after superior capsule reconstruction. The purpose of this study was to investigate the effects of acromioplasty on shoulder biomechanics after superior capsule reconstruction for irreparable supraspinatus tendon tears. The hypothesis was that acromioplasty with superior capsule reconstruction would decrease the area of subacromial impingement without increasing superior translation and subacromial contact pressure. Controlled laboratory study. Seven fresh-frozen cadaveric shoulders were evaluated using a custom shoulder testing system. Glenohumeral superior translation, the location of the humeral head relative to the glenoid, and subacromial contact pressure and area were compared among 4 conditions: (1) intact shoulder, (2) irreparable supraspinatus tendon tear, (3) superior capsule reconstruction without acromioplasty, and (4) superior capsule reconstruction with acromioplasty. Superior capsule reconstruction was performed using the fascia lata. Compared with the intact shoulder, the creation of an irreparable supraspinatus tear significantly shifted the humeral head superiorly in the balanced muscle loading condition (without superior force applied) (0° of abduction: 2.8-mm superior shift [P = .0005]; 30° of abduction: 1.9-mm superior shift [P = .003]) and increased both superior translation (0° of abduction: 239% of intact [P = .04]; 30° of abduction: 199% of intact [P = .02]) and subacromial peak contact pressure (0° of abduction: 308% of intact [P = .0002]; 30° of abduction: 252% of intact [P = .001]) by applying superior force. Superior capsule reconstruction without acromioplasty significantly decreased superior translation (0° of abduction: 86% of intact [P = .02]; 30° of abduction: 75

  5. Teaching medicine with the help of "Dr. House".

    Science.gov (United States)

    Jerrentrup, Andreas; Mueller, Tobias; Glowalla, Ulrich; Herder, Meike; Henrichs, Nadine; Neubauer, Andreas; Schaefer, Juergen R

    2018-01-01

    TV series such as "House MD", "Grey´s Anatomy" or "Emergency Room" are well perceived by medical students. Seminars featuring medical TV series such as "House MD" might serve as door-opener to attract medical students to learn more about rare diseases. The TV series "House MD" is troublesome for the main character Dr. House is an excellent diagnostician but at the same time a rather misanthropic person. Therefore, lecturing medicine with the help of "House MD" requires constant evaluation. From 2008 to 2016 we are using the well-known TV series "House MD" continuously to attract medical students and teach them about rare diseases as well as diagnostic strategies. We collected from 213 students a detailed questionnaire assessing their learning experience. 76.6% of our students (n = 157) reported to watching medical dramas on a regular basis. The Dr. House seminar was compared to traditional seminars and our students reported an improved learning effect (69.9%), better concentration (89.7%), higher motivation to participate (88.7%), and more fun (86.7%) (all pHouse's behavior quite critically. Likert assessment on a 5-point scale identified strong disagreement with Dr. House´s interpersonal skills in dealing with his colleagues (median = 1) and patients (median = 1). At the same time, the students strongly agreed with his outstanding diagnostic (median = 5) and therapeutic capabilities (median = 4). Medical students visiting a Dr. House teaching seminar are highly motivated to learn more about rare diseases. They were positively influenced by TV series such as Dr. House to improve their diagnostic and clinical skills. At the same time, they are critical enough not to see Dr. House as a role model for their own personality. Well performed medical TV shows such as Dr. House can successfully be used in an educational setting to motivate medical students to come into seminars to learn more about rare diseases.

  6. Dr. Tulp's Anatomy Lesson by Rembrandt: the third day hypothesis.

    Science.gov (United States)

    Afek, Arnon; Friedman, Tal; Kugel, Chen; Barshack, Iris; Lurie, Doron J

    2009-07-01

    An autopsy was an important event in 17th century Holland. Autopsies were held in an 'anatomy theater' and performed according to a fixed protocol that often took up to 3 days to complete. Of the five group portraits painted by Rembrandt over the course of his career, two were anatomy lessons given by Dr. Tulp and Dr. Deyman. An examination of Rembrandt's painting Dr. Tulp's Anatomy Lesson (1632) and an X-ray image of the painting, as compared to other paintings of anatomy lessons from the same period, reveal interesting differences, such as positioning, and light and shadow. Not only was the autopsy not performed according to the usual protocol, but in this painting Rembrandt created a unique dramatic scene in his effort to tell a story. We suggest that Dr. Tulp and Rembrandt "modified" the painting of Dr. Tulp's anatomy lesson to emphasize Dr. Tulp's position as the greatest anatomist of his era--"Vesalius of Amsterdam," and as a way of demonstrating God's greatness by highlighting the hand as a symbol of the most glorious of God's creations.

  7. Modular nuclear fuel element, modular capsule for a such element and fabrication process for a modular capsule

    International Nuclear Information System (INIS)

    Chotard, A.

    1988-01-01

    The nuclear fuel rod is made by a tubular casing closed at both ends and containing a series of modular capsules with little play with the casing and made by a jacket closed by porous plugs at both ends and containing a stack of fuel pellets [fr

  8. Brahmayya Sastry, Dr Podila

    Indian Academy of Sciences (India)

    Elected: 1978 Section: Medicine. Brahmayya Sastry, Dr Podila Ph.D. (McGill). Date of birth: 24 May 1913. Date of death: 28 May 1993. Specialization: Physiology, Neurophysiology and Placental Physiology Last known address: Sitaramanilayam, Plot No. 9, Doctors Co-Operative Housing Colony, Waltair, Visakhapatnam ...

  9. Chitnis, Dr Chetan Eknath

    Indian Academy of Sciences (India)

    Home; Fellowship. Fellow Profile. Elected: 2009 Section: Medicine. Chitnis, Dr Chetan Eknath Ph.D. (UC, Berkeley), FNA. Date of birth: 3 April 1961. Specialization: Molecular Parasitology, Vaccine Development for Malaria and Molecular & Cell Biology Address: Head, Malaria Parasite Biology & Vaccine, Institut Pasteur, 28, ...

  10. Sharma, Dr Surendra Kumar

    Indian Academy of Sciences (India)

    Elected: 2010 Section: Medicine. Sharma, Dr Surendra Kumar Ph.D. (AIIMS), MD (PGIMER, Chandigarh), FNASc, FNA. Date of birth: 22 February 1951. Specialization: Environmental Medicine, Infectious Diseases, Internal Medicine, Pulmonary & Critical Care and Sleep Medicine Address: B-5/3, B Block, Sector 13, RK ...

  11. Valluri, Dr Sitaram Rao

    Indian Academy of Sciences (India)

    Home; Fellowship. Fellow Profile. Elected: 1971 Section: Engineering & Technology. Valluri, Dr Sitaram Rao Ph.D. (Caltech). Date of birth: 25 June 1924. Specialization: Metal Fatigue Address: 'Prashanthi', 659, 100 Feet Road, Indiranagar, Bengaluru 560 038, Karnataka Contact: Residence: (080) 2525 8294. YouTube ...

  12. Shastry, Dr B Sriram

    Indian Academy of Sciences (India)

    Shastry, Dr B Sriram Ph.D. (Mumbai), FNA, FNASc, FTWAS. Date of birth: 26 November 1950. Specialization: Strongly-Correlated Fermi Systems, Quantum Integrable Systems Address: Distinguished Professor, Department of Physics, University of California, Santa Cruz, CA 95064, USA Contact: Office: (+1-831) 459 5849

  13. Gangal, Dr Sharad Vishwanath

    Indian Academy of Sciences (India)

    Gangal, Dr Sharad Vishwanath Ph.D. (Mumbai), FNASc. Date of birth: 2 May 1937. Specialization: Allergy, Immunology and Biochemistry Address: Lakshmi Niwas, Opp. Santoshi Mata Temple (B Cabin), Sane Guruji Path, Naupada, Thane 400 602, Maharashtra Contact: Residence: (022) 2537 6961. Mobile: 93249 24307

  14. Paranjpe, Dr Pramod Anand

    Indian Academy of Sciences (India)

    Elected: 1975 Section: Engineering & Technology. Paranjpe, Dr Pramod Anand D.Sc. Tech. (ETH Zurich). Date of birth: 1 April 1934. Specialization: Turbomachinery and Jet Propulsion Systems Address: 'Bahaar', 5, Hindustan Estate, Road No. 13, Kalyaninagar, Pune 411 006, Maharashtra Contact: Residence: (020) 2668 ...

  15. Thakur, Dr Vikram Chandra

    Indian Academy of Sciences (India)

    Home; Fellowship. Fellow Profile. Elected: 1991 Section: Earth & Planetary Sciences. Thakur, Dr Vikram Chandra Ph.D. (London). Date of birth: 15 January 1940. Specialization: Structural Geology, Tectonics of Himalayan Geology and Active Tectonics Address: 9/12 (Lane 9), Ashirwad Eclave, Dehra Dun 248 001, ...

  16. Gangal, Dr Sudha Gajanan

    Indian Academy of Sciences (India)

    Gangal, Dr Sudha Gajanan Ph.D. (Mumbai), FNA Council Service: 1995-97. Date of birth: 25 August 1934. Specialization: Cancer & Basic Immunology, Cell Biology and Genetic Diseases Address: 4, Mahavishnu Apartments, Dahanukar Colony A, Kothrud, Pune 411 029, Maharashtra Contact: Residence: (020) 2538 4382, ...

  17. Mishra, Dr Rakesh K

    Indian Academy of Sciences (India)

    Mishra, Dr Rakesh K Ph.D. (Allahabad), FNASc, FNA. Date of birth: 14 April 1961. Specialization: Genomics, Chromatin, Epigenetics Address: Director, Centre for Cellular & Molecular Biology, Uppal Road, Hyderabad 500 007, A.P.. Contact: Office: (040) 2719 2600. Residence: (040) 2720 6400. Mobile: 94419 02188

  18. Parnaik, Dr Veena Krishnaji

    Indian Academy of Sciences (India)

    Elected: 2008 Section: Animal Sciences. Parnaik, Dr Veena Krishnaji Ph.D. (Ohio State), FNA. Date of birth: 22 August 1953. Specialization: Cell Biology, Molecular Biology, Lamins and Nuclear Organisation Address: INSA Senior Scientist, Centre for Cellular & Molecular Biology, Uppal Road, Hyderabad 500 007, A.P.

  19. 3D Surface Mapping of Capsule Fill-Tube Assemblies used in Laser-Driven Fusion Targets

    Energy Technology Data Exchange (ETDEWEB)

    Buice, E S; Alger, E T; Antipa, N A; Bhandarkar, S D; Biesiada, T A; Conder, A D; Dzenitis, E G; Flegel, M S; Hamza, A V; Heinbockel, C L; Horner, J; Johnson, M A; Kegelmeyer, L M; Meyer, J S; Montesanti, R C; Reynolds, J L; Taylor, J S; Wegner, P J

    2011-02-18

    This paper presents the development of a 3D surface mapping system used to measure the surface of a fusion target Capsule Fill-Tube Assembly (CFTA). The CFTA consists of a hollow Ge-doped plastic sphere, called a capsule, ranging in outer diameter between 2.2 mm and 2.6 mm and an attached 150 {micro}m diameter glass-core fill-tube that tapers down to a 10{micro} diameter at the capsule. The mapping system is an enabling technology to facilitate a quality assurance program and to archive 3D surface information of each capsule used in fusion ignition experiments that are currently being performed at the National Ignition Facility (NIF). The 3D Surface Mapping System is designed to locate and quantify surface features with a height of 50 nm and 300 nm in width or larger. Additionally, the system will be calibrated such that the 3D measured surface can be related to the capsule surface angular coordinate system to within 0.25 degree (1{sigma}), which corresponds to approximately 5 {micro}m linear error on the capsule surface.

  20. 3D Surface Mapping of Capsule Fill-Tube Assemblies used in Laser-Driven Fusion Targets

    International Nuclear Information System (INIS)

    Buice, E.S.; Alger, E.T.; Antipa, N.A.; Bhandarkar, S.D.; Biesiada, T.A.; Conder, A.D.; Dzenitis, E.G.; Flegel, M.S.; Hamza, A.V.; Heinbockel, C.L.; Horner, J.; Johnson, M.A.; Kegelmeyer, L.M.; Meyer, J.S.; Montesanti, R.C.; Reynolds, J.L.; Taylor, J.S.; Wegner, P.J.

    2011-01-01

    This paper presents the development of a 3D surface mapping system used to measure the surface of a fusion target Capsule Fill-Tube Assembly (CFTA). The CFTA consists of a hollow Ge-doped plastic sphere, called a capsule, ranging in outer diameter between 2.2 mm and 2.6 mm and an attached 150 (micro)m diameter glass-core fill-tube that tapers down to a 10(micro) diameter at the capsule. The mapping system is an enabling technology to facilitate a quality assurance program and to archive 3D surface information of each capsule used in fusion ignition experiments that are currently being performed at the National Ignition Facility (NIF). The 3D Surface Mapping System is designed to locate and quantify surface features with a height of 50 nm and 300 nm in width or larger. Additionally, the system will be calibrated such that the 3D measured surface can be related to the capsule surface angular coordinate system to within 0.25 degree (1σ), which corresponds to approximately 5 (micro)m linear error on the capsule surface.

  1. Radiation as a processing aid for upgrading gelatin and gelatin capsules

    International Nuclear Information System (INIS)

    Patel, K.M.; Tantry, M.; Sharma, G.; Gopal, N.G.S.

    1979-01-01

    Gelatin for pharmaceutical use should not contain more than 1000 microorganisms per gram and must not contain pathogenic microorganisms like Salmonella species and E.Coli. For some biological studies spore free gelatin is essential. Locally available gelatin and gelatin capsules have been found to contain a good number of microorganisms. Gelatin and its capsules containing different colours were exposed to graded doses of radiation and stored at different temperatures. They were then examined for microbial content, disintegration characteristics, pH, viscosity and colour change. The study shows that radiation treatment is useful to upgrade microbiologically both gelatin and its capsules. This technique provides apparently a useful and economic method for producing spore free gelatin which in commerce is relatively expensive. (auth.)

  2. Radiation as a processing aid for upgrading gelatin and gelatin capsules

    Energy Technology Data Exchange (ETDEWEB)

    Patel, K M; Tantry, M; Sharma, G; Gopal, N G.S. [Bhabha Atomic Research Centre, Bombay (India). ISOMED

    1979-01-01

    Gelatin for pharmaceutical use should not contain more than 1000 microorganisms per gram and must not contain pathogenic microorganisms like Salmonella species and E.Coli. For some biological studies spore free gelatin is essential. Locally available gelatin and gelatin capsules have been found to contain a good number of microorganisms. Gelatin and its capsules containing different colours were exposed to graded doses of radiation and stored at different temperatures. They were then examined for microbial content, disintegration characteristics, pH, viscosity and colour change. The study shows that radiation treatment is useful to upgrade microbiologically both gelatin and its capsules. This technique provides apparently a useful and economic method for producing spore free gelatin which in commerce is relatively expensive.

  3. Dr. Shi Hanzhang's Experience in Treating Andropathy

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    @@ Dr. Shi Hanzhang (施汉章) of Dongzhimen Hospital affiliated to Beijing University of Traditional Chinese Medicine is experienced in both teaching and clinical practice, especially in treating andropathy, such as sexual disorder, infertility, and hyperplasia of the prostate. The author has the honour to follow him for study and really learned a lot from him. A brief introduction to Dr. Shi's way of thinking in treatment is as follows.

  4. Stochastic Capsule Endoscopy Image Enhancement

    Directory of Open Access Journals (Sweden)

    Ahmed Mohammed

    2018-06-01

    Full Text Available Capsule endoscopy, which uses a wireless camera to take images of the digestive tract, is emerging as an alternative to traditional colonoscopy. The diagnostic values of these images depend on the quality of revealed underlying tissue surfaces. In this paper, we consider the problem of enhancing the visibility of detail and shadowed tissue surfaces for capsule endoscopy images. Using concentric circles at each pixel for random walks combined with stochastic sampling, the proposed method enhances the details of vessel and tissue surfaces. The framework decomposes the image into two detailed layers that contain shadowed tissue surfaces and detail features. The target pixel value is recalculated for the smooth layer using similarity of the target pixel to neighboring pixels by weighting against the total gradient variation and intensity differences. In order to evaluate the diagnostic image quality of the proposed method, we used clinical subjective evaluation with a rank order on selected KID image database and compared it to state-of-the-art enhancement methods. The result showed that the proposed method provides a better result in terms of diagnostic image quality and objective quality contrast metrics and structural similarity index.

  5. Volume celebrating the 60th birthday of Professor Dr. Franz Fie; Professor Dr. Franz Fiedler zum 60. Geburtstag

    Energy Technology Data Exchange (ETDEWEB)

    Beheng, K.D. [ed.

    1998-01-01

    This report was compiled in honor of Professor Dr. Franz Fiedler on the occasion of his 60th birthday on 7 January 1998. Its contributions deal with mesoscale modelling, the propagation of air pollutants, measurements of precipitation using radar, and prediction models. (orig./KW) [Deutsch] Dieser Bericht wurde aus Anlass des 60. Geburtstags von Herrn Prof. Dr. Franz Fiedler am 7. Januar 1998 zusammengestellt. Die Beitraege behandeln mesoskalige Modellierung, Ausbreitung von Luftschadstoffen, Niederschlagsmessung mit Radar und Vorhersagemodelle. (orig.)

  6. A novel diagnostic tool for detecting functional patency of the small bowel: the Given patency capsule.

    Science.gov (United States)

    Spada, C; Spera, G; Riccioni, M; Biancone, L; Petruzziello, L; Tringali, A; Familiari, P; Marchese, M; Onder, G; Mutignani, M; Perri, V; Petruzziello, C; Pallone, F; Costamagna, G

    2005-09-01

    The current visualization of small-bowel strictures using traditional radiological methods is associated with high radiation doses and false-negative results. These methods do not always reveal small-bowel patency for solids. The aim is to assess the safety of the Given patency system and its ability to detect intestinal strictures in patients with strictures that are known or suspected radiologically. The Given patency capsule is composed of lactose, remains intact in the gastrointestinal tract for 40-100 hours post ingestion, and disintegrates thereafter. A total of 34 patients with small-bowel stricture were prospectively enrolled; 30 had a previous diagnosis of Crohn's disease, three had adhesion syndrome and in one ischemic enteritis was suspected. Of the patients, 15 (44.1 %) had previously undergone surgery. Following ingestion, the capsule was monitored for integrity and transit time, using a specially designed Given scanner and also radiologically. Seventeen patients had been enrolled with the intent of using the patency capsule as a preliminary test in patients with small-bowel strictures before undergoing video capsule endoscopy. 30 patients (88.2 %) retrieved the capsule in the stool; it was intact in 20 (median transit time 22 hours), and disintegrated in 10 patients (median transit time 53 hours). Six patients complained of abdominal pain which disappeared within 24 hours. The scanner successfully indicated the presence of the capsule in 94 % of cases. Ten patients underwent video capsule endoscopy following the patency capsule examination; in all of these the video capsule passed through the small-bowel stricture. This feasibility study has shown that the Given patency capsule is a safe, effective, and convenient tool for assessment of functional patency of the small bowel. It can indicate functional patency even in cases where traditional radiology indicates stricture.

  7. Demonstration of Polysaccharide Capsule in Campylobacter jejuni Using Electron Microscopy

    OpenAIRE

    Karlyshev, Andrey V.; McCrossan, Maria V.; Wren, Brendan W.

    2001-01-01

    Recently, we reported that Campylobacter jejuni, an important gastrointestinal pathogen, has the genetic determinants to produce a capsular polysaccharide (Karlyshev et al., Mol. Microbiol. 35:529–541, 2000). Despite these data, the presence of a capsule in these bacteria has remained controversial. In this study we stain C. jejuni cells with the cationic dye Alcian blue and demonstrate for the first time by electron microscopy that C. jejuni cells produce a polysaccharide capsule that is ret...

  8. For Dr. Nancy Snyderman's Parents, Staying Close to Family Is Key

    Science.gov (United States)

    ... to move closer to their daughter and her family, as part of the next chapter in their lives. Photo courtesy of Dr. Nancy Snyderman As Chief Medical Editor for NBC News and host of the popular MSNBC show, Dr. Nancy , Dr. ...

  9. DR and CR: Recent advances in technology

    International Nuclear Information System (INIS)

    Schaefer-Prokop, C.M.; De Boo, D.W.; Uffmann, M.; Prokop, M.

    2009-01-01

    After some initial reluctance, nowadays transition from conventional analogue-to-digital radiographic technique is realized in the vast majority of institutions. The eventual triumph of digital over conventional technique is related to its undoubted advantages with respect to image quality and improved image handling in the context of a picture archiving and communication system. CR represents the older system, which matured over decades and experienced some important recent improvements with respect to dose efficiency and work-flow efficiency that strengthened its position. It represents a very versatile, economically attractive system that is equally suited for integrated systems as well as for cassette-based imaging at the bedside. DR systems offer superb image quality and realistic options for dose reduction based on their high dose efficiency. While for a long time only integrated systems were on the market suited for a large patient throughput, also mobile DR systems became recently available. While for the next years, it is likely that DR and CR systems will coexist, the long term perspective of CR will depend on further innovations with respect to dose efficiency and signal-to-noise characteristics while for DR economical aspects and broader availability of mobile systems will play a role.

  10. Bal, Dr Dattatreya Vaman

    Indian Academy of Sciences (India)

    Home; Fellowship. Fellow Profile. Elected: 1943 Section: Animal Sciences. Bal, Dr Dattatreya Vaman Ph.D. (Liverpool). Date of birth: 25 August 1905. Date of death: 1 April 1999. Specialization: Marine Zoology, Oceanography. Fisheries and Aquaculture Last known address: 104, Swaroop Complex, Karve Road, Pune 411 ...

  11. Bhawalkar, Dr Dilip Devidas

    Indian Academy of Sciences (India)

    Fellow Profile. Elected: 1986 Section: Physics. Bhawalkar, Dr Dilip Devidas Ph.D. (Southampton), FNA, FNASc. Date of birth: 16 October 1940. Specialization: Lasers and laser Instrumentation Address: 26, Paramanu Nagar, Indore 452 013, M.P.. Contact: Office: (0731) 232 2707. Residence: (0731) 232 0031. Mobile: 93032 ...

  12. Agrewala, Dr Javed Naim

    Indian Academy of Sciences (India)

    Agrewala, Dr Javed Naim Ph.D. (Agra), FNA, FNASc. Date of birth: 14 May 1961. Specialization: Immunology, Vaccine, Drug Discovery Address: Chief Scientist, Immunology Laboratory, Institute of Microbial Technology, Sector 39A, Chandigarh 160 036, U.T.. Contact: Office: (0172) 666 5261. Residence: (0172) 666 5514

  13. Barua, Dr Asok Kumar

    Indian Academy of Sciences (India)

    Elected: 1987 Section: Physics. Barua, Dr Asok Kumar Ph.D. (Calcutta). Date of birth: 1 July 1936. Specialization: Solid State Materials, Thin Film Technology and Thin Film Solar Cells Address: Honorary Emeritus Professor, Indian Institute of Engineering Science & Technology, Shibpur, Howrah 711 103, W.B.. Contact:

  14. Gurjar, Dr Mukund Keshao

    Indian Academy of Sciences (India)

    Gurjar, Dr Mukund Keshao Ph.D. (Nagpur and London), FNASc. Date of birth: 28 August 1952. Specialization: Carbohydrate Chemistry and Synthetic Organic Chemistry Address: Director, R&D, Emcure Pharmaceuticals Limited, P2, ITBT Park Phase II, Hinjwadi, Pune 411 057, Maharashtra Contact: Office: (020) 3982 1350, ...

  15. TEMPO-oxidized Konjac glucomannan as appliance for the preparation of hard capsules

    NARCIS (Netherlands)

    Chen, Yuying; Zhao, Huiying; Liu, Xianwu; Li, Zusen; Liu, Bin; Wu, Jiande; Shi, Mengxuan; Norde, Willem; Li, Yuan

    2016-01-01

    TEMPO-oxidized Konjac glucomannan (OKGM) was developed as new material for preparing vegetarian hard capsules. OKGM of different degrees of oxidation: DO30%, DO50%, and DO80% were prepared to select optimum DO for capsule formation. FT-IR results proved that the primary alcohol groups on KGM were

  16. Arthroscopic treatment of refractory adhesive capsulitis of the shoulder

    Directory of Open Access Journals (Sweden)

    Marcos Rassi Fernandes

    Full Text Available OBJECTIVE: to evaluate the results of arthroscopic treatment of refractory adhesive capsulitis of the shoulder associated as for improved range of motion after a minimum follow up of six years. METHODS: from August 2002 to December 2004, ten patients with adhesive capsulitis of the shoulder resistant to conservative treatment underwent arthroscopic surgery. One interscalene catheter was placed for postoperative analgesia before the procedure. All were in Phase II, with a minimum follow up of two years. The mean age was 52.9 years (39-66, predominantly female (90%, six on the left shoulder. The time between onset of symptoms and surgical treatment ranged from six to 20 months. Four adhesive capsulitis were found to be primary (40% and six secondary (60%. RESULTS: the preoperative mean of active anterior elevation was 92°, of external rotation was 10.5° of the L5 level internal rotation; the postoperative ones were 149°, 40° and T12 level, respectively. Therefore, the average gain was 57° for the anterior elevation, 29.5° for external rotation in six spinous processes. There was a significant difference in movements' gains between the pre and post-operative periods (p<0.001. By the Constant Score (range of motion, there was an increase of 13.8 (average pre to 32 points (average post. CONCLUSION: the arthroscopic treatment proved effective in refractory adhesive capsulitis of the shoulder resistant to conservative treatment, improving the range of joint movements of patients evaluated after a minimum follow up of six years.

  17. Adhesive capsulitis: role of MR imaging in differential diagnosis

    International Nuclear Information System (INIS)

    Connell, David; Padmanabhan, Ravi; Buchbinder, Rachelle

    2002-01-01

    The purpose of this study was to describe and characterize the MR imaging findings in a group of patients who underwent surgery for adhesive capsulitis. Twenty-four MR imaging studies in 24 consecutive patients with clinical evidence of adhesive capsulitis were performed prior to arthroscopic capsulotomy. There were 17 women and 7 men with a mean age of 53.5 years. Images were scrutinised for changes in the synovium particularly in the rotator interval, around the biceps anchor and axillary pouch. Intravenous gadolinium was given routinely. We also examined a control group of 22 patients who underwent the same MR imaging protocol after referral for rotator cuff pathology. Soft tissue density showing variable enhancement after gadolinium administration was visible in the rotator interval in 22 of 24 studies on MR imaging. Seventeen patients showed soft tissue density partially encasing the biceps anchor. Ten patients showed thickening and gadolinium enhancement of the axillary pouch. Three patients from the study cohort had partial tears of the supraspinatus tendon. All the patients subsequently had surgery which confirmed fibrovascular scar tissue in the rotator interval, around the biceps anchor and a variable degree of synovial inflammation of the glenohumeral capsule. Two patients from a control group with suspected rotator cuff pathology showed abnormal intensity in the rotator interval on MR imaging. Magnetic resonance imaging can identify changes in the shoulder joint that correspond to abnormalities seen at surgery. This may be useful for discriminating adhesive capsulitis from other causes of shoulder pain. (orig.)

  18. Wireless capsule endoscopy in adolescents with familial adenomatous polyposis.

    Science.gov (United States)

    Cavallo, Debora; Ballardini, Giovanni; Ferrari, Andrea; Delconte, Gabriele; Signoroni, Stefano; Sala, Paola; Chiaravalli, Stefano; Massimino, Maura; Bertario, Lucio; Vitellaro, Marco

    2016-01-01

    Guidelines for surveillance in patients with familial adenomatous polyposis (FAP) recommend mutation carriers to undergo periodic colorectal examination starting in the early teens. Performing colonoscopy in children may lead to complications. Wireless capsule endoscopy (WCE) has been introduced recently to evaluate both the upper and lower gastrointestinal tract, and seems suitable as a first screening examination for adolescents. The aim of this study was to evaluate the pros and cons of WCE. This was a retrospective review of a single institution database of adolescent patients with FAP identified through the Hereditary Colorectal Tumor Registry between 2007 and 2013. The main outcomes were identification of upper and lower gastrointestinal tract polyps, tolerance of the examination, and number and size of polyps. Of 46 adolescent patients with FAP, 14 (30.4%) patients carrying adenomatous polyposis coli gene (APC) mutation, 6 male and 8 female, age (median, range) 12 (10-17) years, body mass index 19 (13-24), underwent WCE as first screening examination. The examination was completed in 13 patients (93.3%). Wireless capsule endoscopy identified the duodenal papilla in 4 patients and colonic and rectal polyps in all 13 patients. In 7 patients, fewer than 25 polyps were identified. No complications were recorded related to the use of the video capsule. Wireless capsule endoscopy is feasible and well-tolerated as a first screening examination in adolescent patients. It cannot be used as alternative to the colonoscopy, but could improve compliance with colonoscopy, and increase early adherence to a surveillance program.

  19. Relative bioavailability of rifampicin, isoniazid and ethambutol from a combination tablet vs. concomitant administration of a capsule containing rifampicin and a tablet containing isoniazid and ethambutol.

    Science.gov (United States)

    Schall, R; Müller, F O; Duursema, L; Groenewoud, G; Hundt, H K; Middle, M V; Mogilnicka, E M; Swart, K J

    1995-11-01

    Twenty male volunteers who were slow metabolisers of isoniazid, completed this single-blind, single-dose, randomised, cross-over study to compare the bioavailability of rifampicin (CAS 13292-46-1), isoniazid (CAS 54-85-3) and ethambutol (CAS 1070-11-7) from Myrin tablets (test preparation) with the bioavailability of these drugs from a combination of capsules containing rifampicin and tablets containing isoniazid and ethambutol (reference). There were 2 treatment periods and on clinic days volunteers were given either the reference (300 mig rifampicin plus 200 mg isoniazid and 600 mg ethambutol HCl), or the test preparation (300 mg rifampicin, 150 mg isoniazid and 600 mg ethambutol HCl). Serial blood samples were drawn from the volunteers and rifampicin, isoniazid and ethambutol assays were performed. The results of this study indicate that the test preparation is equivalent to the reference with respect to both the rate and the extent of absorption of rifampicin, isoniazid (after adjustment for the different doses of isoniazid and ethambutol).

  20. Fabrication of hybrid graphene oxide/polyelectrolyte capsules by means of layer-by-layer assembly on erythrocyte cell templates

    Directory of Open Access Journals (Sweden)

    Joseba Irigoyen

    2015-12-01

    Full Text Available A novel and facile method was developed to produce hybrid graphene oxide (GO–polyelectrolyte (PE capsules using erythrocyte cells as templates. The capsules are easily produced through the layer-by-layer technique using alternating polyelectrolyte layers and GO sheets. The amount of GO and therefore its coverage in the resulting capsules can be tuned by adjusting the concentration of the GO dispersion during the assembly. The capsules retain the approximate shape and size of the erythrocyte template after the latter is totally removed by oxidation with NaOCl in water. The PE/GO capsules maintain their integrity and can be placed or located on other surfaces such as in a device. When the capsules are dried in air, they collapse to form a film that is approximately twice the thickness of the capsule membrane. AFM images in the present study suggest a film thickness of approx. 30 nm for the capsules in the collapsed state implying a thickness of approx. 15 nm for the layers in the collapsed capsule membrane. The polyelectrolytes used in the present study were polyallylamine hydrochloride (PAH and polystyrenesulfonate sodium salt (PSS. Capsules where characterized by transmission electron microscopy (TEM, atomic force microscopy (AFM, dynamic light scattering (DLS and Raman microscopy, the constituent layers by zeta potential and GO by TEM, XRD, and Raman and FTIR spectroscopies.

  1. Increased Risk for Adhesive Capsulitis of the Shoulder following Cervical Disc Surgery.

    Science.gov (United States)

    Kang, Jiunn-Horng; Lin, Herng-Ching; Tsai, Ming-Chieh; Chung, Shiu-Dong

    2016-05-27

    Shoulder problems are common in patients with a cervical herniated intervertebral disc (HIVD). This study aimed to explore the incidence and risk of shoulder capsulitis/tendonitis following cervical HIVD surgery. We used data from the Taiwan "Longitudinal Health Insurance Database". We identified all patients who were hospitalized with a diagnosis of displacement of a cervical HIVD and who underwent cervical surgery (n = 1625). We selected 8125 patients who received cervical HIVD conservative therapy only as the comparison group matched with study patients. We individually tracked these sampled patients for 6 months to identify all patients who received a diagnosis of shoulder tendonitis/capsulitis. We found that incidence rates of shoulder tendonitis/capsulitis during the 6-month follow-up period were 3.69 (95% CI: 2.49~5.27) per 100 person-years for the study group and 2.33 (95% CI: 1.89~2.86) per 100 person-years for the comparison group. Cox proportional hazard regressions showed that the adjusted hazard ratio for shoulder tendonitis/capsulitis among patients who underwent cervical disc surgery was 1.66 (95% CI = 1.09~2.53) when compared to comparison group. We concluded that patients who underwent surgery for a cervical HIVD had a significantly higher risk of developing shoulder capsulitis/tendonitis in 6 months follow-up compared to patients who received cervical HIVD conservative therapy only.

  2. Urea-functionalized crystalline capsules for recognition and separation of tetrahedral oxoanions

    Energy Technology Data Exchange (ETDEWEB)

    Custelcean, Radu [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Chemical Sciences Division

    2012-12-21

    We reviewed the persistent ability of tripodal TREN-based tris-urea receptors (TREN = tris(2-aminoethyl)amine) to self-assemble with a variety of oxoanions into dimeric capsules upon crystallization. The capsule crystallization allows for charge-, shape-, and size-selective encapsulation of tetrahedral XO4n-anions (n = 2,3), and provides an effective way to separate these anions from competitive aqueous environments.

  3. Cystic adventitial degeneration: ectopic ganglia from adjacent joint capsules.

    Science.gov (United States)

    Ortmann, J; Widmer, M K; Gretener, S; Do, D D; Willenberg, T; Daliri, A; Baumgartner, I

    2009-11-01

    Cystic adventitial degeneration is a rare non-atherosclerotic cause of peripheral arterial occlusive disease, mainly seen in young men without other evidence of vascular disease. Diagnosis will be established by clinical findings and by ultrasound or angiography and can be treated by excision or enucleation of the affected arterial segment or by percutaneous ultrasound-guided aspiration. However, the etiology of adventitial cysts remains unknown. We report a case of cystic adventitial degeneration showing a connection between the joint capsule and the adventitial cyst, supporting the theory that cystic adventitial degeneration may represent ectopic ganglia from adjacent joint capsules.

  4. Advances in pediatric gastroenterology: introducing video camera capsule endoscopy.

    Science.gov (United States)

    Siaw, Emmanuel O

    2006-04-01

    The video camera capsule endoscope is a gastrointestinal endoscope approved by the U.S. Food and Drug Administration in 2001 for use in diagnosing gastrointestinal disorders in adults. In 2003, the agency approved the device for use in children ages 10 and older, and the endoscope is currently in use at Arkansas Children's Hospital. A capsule camera, lens, battery, transmitter and antenna together record images of the small intestine as the endoscope makes its way through the bowel. The instrument is used with minimal risk to the patient while offering a high degree of accuracy in diagnosing small intestine disorders.

  5. Overall properties of the Gaia DR1 reference frame

    Science.gov (United States)

    Liu, N.; Zhu, Z.; Liu, J.-C.; Ding, C.-Y.

    2017-03-01

    Aims: The first Gaia data release (Gaia DR1) provides 2191 ICRF2 sources with their positions in the auxiliary quasar solution and five astrometric parameters - positions, parallaxes, and proper motions - for stars in common between the Tycho-2 catalogue and Gaia in the joint Tycho-Gaia astrometric solution (TGAS). We aim to analyze the overall properties of Gaia DR1 reference frame. Methods: We compare quasar positions of the auxiliary quasar solution with ICRF2 sources using different samples and evaluate the influence on the Gaia DR1 reference frame owing to the Galactic aberration effect over the J2000.0-J2015.0 period. Then we estimate the global rotation between TGAS with Tycho-2 proper motion systems to investigate the property of the Gaia DR1 reference frame. Finally, the Galactic kinematics analysis using the K-M giant proper motions is performed to understand the property of Gaia DR1 reference frame. Results: The positional comparison between the auxiliary quasar solution and ICRF2 shows negligible orientation and validates the declination bias of -0.1mas in Gaia quasar positions with respect to ICRF2. Galactic aberration effect is thought to cause an offset 0.01mas of the Z axis direction of Gaia DR1 reference frame. The global rotation between TGAS and Tycho-2 proper motion systems, obtained by different samples, shows a much smaller value than the claimed value 0.24mas yr-1. For the Galactic kinematics analysis of the TGAS K-M giants, we find possible non-zero Galactic rotation components beyond the classical Oort constants: the rigid part ωYG = -0.38±0.15mas yr-1 and the differential part ω^primeYG = -0.29±0.19mas yr-1 around the YG axis of Galactic coordinates, which indicates possible residual rotation in Gaia DR1 reference frame or problems in the current Galactic kinematical model. Conclusions: The Gaia DR1 reference frame is well aligned to ICRF2, and the possible influence of the Galactic aberration effect should be taken into consideration

  6. Nageswara Rao, Dr Gullapalli

    Indian Academy of Sciences (India)

    Nageswara Rao, Dr Gullapalli M.D. (Opthal.) (AIIMS), FAMS, FACS, FRCS, FNASc. Date of birth: 1 September 1945. Specialization: Cornea, Community Eye Health and Eye Care Policy & Planning Address: Distinguished Chair of Eye Health, LV Prasad Eye Institute, LV Prasad Marg, Banjara Hills, Hyderabad 500 034, A.P.

  7. Ghosh, Dr Pushpito Kumar

    Indian Academy of Sciences (India)

    Home; Fellowship. Fellow Profile. Elected: 2010 Section: Chemistry. Ghosh, Dr Pushpito Kumar Ph.D. (Princeton). Date of birth: 29 May 1954. Specialization: Processes Research, Water Purification, Renewable Energy, R&D Management Address: A-604, Punit Park, Plot No. 182/C, Sector 17, Merol, Navi Mumbai 400 706, ...

  8. Nandicoori, Dr Vinay Kumar

    Indian Academy of Sciences (India)

    Home; Fellowship. Fellow Profile. Elected: 2018 Section: General Biology. Nandicoori, Dr Vinay Kumar Ph.D. (IISc), FNASc. Date of birth: 1 March 1969. Specialization: Molecular & Cellular Biology, Cell Signalling, Cell Biology Address: National Institute of Immunology, Aruna Asaf Ali Marg, New Delhi 110 067, U.T.; Contact ...

  9. Panda, Dr Subrat Kumar

    Indian Academy of Sciences (India)

    Panda, Dr Subrat Kumar M.B.B.S. (Utkal), M.D. (Path.) (AIIMS), FNA. Date of birth: 18 November 1954. Specialization: Liver Pathology, Viral Hepatitis and Molecular Biology/Virology Address: Professor, Department of Pathology, All India Institute of Medical Sciences, Ansari Nagar, New Delhi 110 029, U.T.. Contact:

  10. Basu, Dr Sandip Kumar

    Indian Academy of Sciences (India)

    Fellow Profile. Elected: 1992 Section: General Biology. Basu, Dr Sandip Kumar Ph.D. (Calcutta), FNASc, FNA, FTWAS Council Service: 1995-97. Date of birth: 1 January 1944. Specialization: Cell Biology, Molecular Biology and Microbial Genetics Address: FD-426, Sector 3, Bidhan Nagar, Kolkata 700 106, W.B.. Contact:

  11. Water Landing Impact of Recovery Space Capsule: A Research Overview

    OpenAIRE

    Nakano, Eiichiro; Uchikawa, Hideaki; Tanno, Hideyuki; Sugimoto, Ryu

    2014-01-01

    For the design of a manned or cargo space capsule, it is important to precisely estimate the Earth landing loads to the crew or cargo, and to limit the loads to within a permissible range. Water landing simulations and scale-model water landing tests with varying conditions for descending velocity, pitch angle, and horizontal velocity during splashdown were conducted to estimate the magnitude of water impact on the recovery space capsule. This paper describes the results of the simulation and...

  12. Status for development of a capsule and instruments for high-temperature irradiation in HANARO

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Man Soon; Choo, Kee Nam; Lee, Chul Yong; Yang, Seong Woo; Shim, Kyue Taek; Chung, Hwan-Sung [Korea Atomic Energy Research Institute, Taejeon (Korea, Republic of)

    2012-03-15

    As the reactors planned in the Gen-IV program will be operated at high temperature and under high neutron flux, the requirements for irradiation of materials at high temperature are recently being gradually increased. The irradiation tests of materials in HANARO up to the present have been performed usually at temperatures below 300degC at which the RPV materials of the commercial reactors are being operated. To overcome the restriction for high-temperature use of Al thermal media of the existing standard capsule, a new capsule with double thermal media composed of two kinds of materials such as Al-Ti and Al-graphite was designed and fabricated as a more advanced capsule than the single thermal media capsule. (author)

  13. Design Improvements of the Capsule Components and the Handling Tools for an Effective Utilization of the Capsule Assembly Machine

    International Nuclear Information System (INIS)

    Kang, Young Hwan; Kim, Jong Kium; Youm, Ki Un; Yoon, Ki Byung; Choi, Myung Hwan; Kim, Bong Gu

    2006-01-01

    Various in-pile test programs for the development of new fuels and materials are planned for the HANARO reactor. To meet the demands for the required tests in the HANARO reactor, new capsule assembling technology is required in the HANARO reactor. For this reason, a series of analyses and experiments was performed in 2005. For the assembly workability tests of the capsule components, three different kinds of protection tubes and two different shapes of the locking bolt heads were proposed and tested. It was confirmed that the newly designed protection tube and bolts worked quite well without any problems. Since the new structure is quite similar to that of the currently used capsule, it was assumed that an additional vibration tests and seismic analysis would not be needed. Through the stress analysis of the three proposed structures by using ANSYS code, it showed that the maximum displacement and stress intensity for the tube reducer were 1.57mm and 21MPa, respectively. To improve the workability and handling capability of the bolting and clamping tools of stainless steel 304, Al6061/T6 was selected as one of the candidates and thus new tools were manufactured and tested. The assembly test results showed that the new tools were found to be useful for executing key tasks such as a bolting and a clamping and they were much faster than the old tools made of stainless steel, thereby increasing the workability rate and lowering the manufacturing costs

  14. Efficacy of Qianggan capsule in treatment of non-alcoholic fatty liver disease complicated with hyperlipidemia

    Directory of Open Access Journals (Sweden)

    Zhi-Jun He

    2016-07-01

    Full Text Available Objective: To observe the clinical effects of Qianggan capsule and silibinin capsule in the treatment of non-alcoholic fatty liver disease complicated with hyperlipidemia. Methods: A total of 112 patients with non-alcoholic fatty liver disease were included in the study and divided into the control group (n=50 and the observation group (n=62. The patients in the control group were given silibinin capsule, while the patients in the observation group were given Qianggan capsule. The patients in the two groups were treated for 24 weeks. The liver/ spleen CT was performed before and after treatment. BMI was measured. The liver function, serum lipid, and leptin were detected. Results: TG, LDL-C, BMI, and liver/spleen CT ratio in the observation group were significantly reduced when compared with the control group. The levels of HDL-C and adiponectin in the observation group were significantly elevated when compared with the control group. The differences of ALT, GGT, and AST after treatment between the two groups were not statistically significant. Conclusions: Qianggan capsule and silibinin capsule has an accurate efficacy and high safety in the treatment of non-alcoholic fatty liver disease complicated with hyperlipidemia.

  15. Thallium(I) sorption using Prussian blue immobilized in alginate capsules.

    Science.gov (United States)

    Vincent, Thierry; Taulemesse, Jean-Marie; Dauvergne, Agnès; Chanut, Thomas; Testa, Flaviano; Guibal, Eric

    2014-01-01

    Prussian blue (PB) was immobilized in alginate capsules. The composite sorbent was used for the recovery of Tl(I) ions from slightly acidic solutions: optimum pH being close to 4. The sorption isotherm can be described by the bi-site Langmuir sorption isotherm. This means that the metal ion can be bound through two different sorption sites: one having a strong affinity for Tl(I) (probably PB), the other having a lower affinity (probably the encapsulating material). The kinetics are described by either the pseudo-second order rate equation or the Crank's equation (resistance to intraparticle diffusion). The ionic strength (increased by addition of NaCl, KCl or CaCl₂) slightly decreased sorption capacity. The SEM-EDX analysis of PB-alginate capsules (before and after Tl(I) sorption) shows that the PB is homogeneously distributed in the capsules and that all reactive groups remain available for metal binding. Copyright © 2013 Elsevier Ltd. All rights reserved.

  16. Reduced anterior internal capsule white matter integrity in primary insomnia.

    Science.gov (United States)

    Spiegelhalder, Kai; Regen, Wolfram; Prem, Martin; Baglioni, Chiara; Nissen, Christoph; Feige, Bernd; Schnell, Susanne; Kiselev, Valerij G; Hennig, Jürgen; Riemann, Dieter

    2014-07-01

    Chronic insomnia is one of the most prevalent central nervous system diseases, however, its neurobiology is poorly understood. Up to now, nothing is known about the integrity of white matter tracts in insomnia patients. In this study, diffusion tensor imaging (DTI) was used in a well-characterized sample of primary insomnia (PI) patients and good sleeper controls to fill this void. Voxelwise between-group comparisons of fractional anisotropy (FA) were performed in 24 PI patients (10 males; 14 females; 42.7 ± 14.5 years) and 35 healthy good sleepers (15 males; 20 females; 40.1 ± 9.1 years) with age and sex as covariates. PI patients showed reduced FA values within the right anterior internal capsule and a trend for reduced FA values in the left anterior internal capsule. The results suggest that insomnia is associated with a reduced integrity of white matter tracts in the anterior internal capsule indicating that disturbed fronto-subcortical connectivity may be a cause or consequence of the disorder.

  17. Development of a High Efficiency Dry Powder Inhaler: Effects of Capsule Chamber Design and Inhaler Surface Modifications

    Science.gov (United States)

    Behara, Srinivas R.B.; Farkas, Dale R.; Hindle, Michael; Longest, P. Worth

    2013-01-01

    Purpose The objective of this study was to explore the performance of a high efficiency dry powder inhaler (DPI) intended for excipient enhanced growth (EEG) aerosol delivery based on changes to the capsule orientation and surface modifications of the capsule and device. Methods DPIs were constructed by combining newly designed capsule chambers (CC) with a previously developed three-dimensional (3D) rod array for particle deagglomeration and a previously optimized EEG formulation. The new CCs oriented the capsule perpendicular to the incoming airflow and were analyzed for different air inlets at a constant pressure drop across the device. Modifications to the inhaler and capsule surfaces included use of metal dispersion rods and surface coatings. Aerosolization performance of the new DPIs was evaluated and compared with commercial devices. Results The proposed capsule orientation and motion pattern increased capsule vibrational frequency and reduced the aerosol MMAD compared with commercial/modified DPIs. The use of metal rods in the 3D array further improved inhaler performance. Coating the inhaler and capsule with PTFE significantly increased emitted dose (ED) from the optimized DPI. Conclusions High efficiency performance is achieved for EEG delivery with the optimized DPI device and formulation combination producing an aerosol with MMAD 90%, and ED > 80%. PMID:23949304

  18. Development of a high efficiency dry powder inhaler: effects of capsule chamber design and inhaler surface modifications.

    Science.gov (United States)

    Behara, Srinivas R B; Farkas, Dale R; Hindle, Michael; Longest, P Worth

    2014-02-01

    The objective of this study was to explore the performance of a high efficiency dry powder inhaler (DPI) intended for excipient enhanced growth (EEG) aerosol delivery based on changes to the capsule orientation and surface modifications of the capsule and device. DPIs were constructed by combining newly designed capsule chambers (CC) with a previously developed three-dimensional (3D) rod array for particle deagglomeration and a previously optimized EEG formulation. The new CCs oriented the capsule perpendicular to the incoming airflow and were analyzed for different air inlets at a constant pressure drop across the device. Modifications to the inhaler and capsule surfaces included use of metal dispersion rods and surface coatings. Aerosolization performance of the new DPIs was evaluated and compared with commercial devices. The proposed capsule orientation and motion pattern increased capsule vibrational frequency and reduced the aerosol MMAD compared with commercial/modified DPIs. The use of metal rods in the 3D array further improved inhaler performance. Coating the inhaler and capsule with PTFE significantly increased emitted dose (ED) from the optimized DPI. High efficiency performance is achieved for EEG delivery with the optimized DPI device and formulation combination producing an aerosol with MMAD  90%, and ED > 80%.

  19. 21 CFR 189.301 - Tin-coated lead foil capsules for wine bottles.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Tin-coated lead foil capsules for wine bottles. 189... SERVICES (CONTINUED) FOOD FOR HUMAN CONSUMPTION (CONTINUED) SUBSTANCES PROHIBITED FROM USE IN HUMAN FOOD... lead foil capsules for wine bottles. (a) Tin-coated lead foil is composed of a lead foil coated on one...

  20. [Effect analysis on Deanxit combined with Shuganjieyu capsule in the treatment of refractory gastroesophageal reflux disease].

    Science.gov (United States)

    Yang, X Y; Guo, C Y; Zhang, X; Zhong, Y Q; Tian, C

    2017-11-28

    Objective: To investigate the curative effect of Deanxit combined with Shuganjieyu capsule on the treatment of refractory gastroesophageal reflux disease. Methods: A total of 125 patients with refractory gastroesophageal reflux disease who had failed in standard lansolazole capsule treatment in the Department of Gastroenterology, First People's Hospital of Neijiang were selected. According to the symptom scores and mood scores of gastroesophageal reflux disease, patients were randomly and double-blindly divided into five groups. Group A(Lansoprazole Capsules + Mosapride Citrate + Deanxit), B(Lansoprazole Capsules + Mosapride Citrate + Shuganjieyu capsule), C(Lansoprazole Capsules + Mosapride Citrate+ Deanxit + Shuganjieyu capsule) and D(Deanxit) groups are study groups, the other was control group (Lansoprazole Capsules + Mosapride Citrate). The scores of symptoms and mood were compared after 4 weeks and 8 weeks of treatment. Results: The clinical symptoms score, HAMA and HAMD scores were significantly lower in the all study groups in comparison to the control group after 4 weeks and 8 weeks therapy. The clinical symptoms score, HAMA and HAMD scores in group C were significantly lower than those in group A and B ( P 0.05). The HAMA and HAMD scores of group D were significantly higher than those of group A, B, C and control group, and the differences were statistically significant ( P gastroesophageal reflux disease, which can effectively improve the total treatment efficiency, reduce the symptom scores and mood scores of gastroesophageal reflux disease patients.

  1. Out-pile test of non-instrumented capsule for the advanced PWR fuel pellets in HANARO irradiation test

    Energy Technology Data Exchange (ETDEWEB)

    Kim, D. H.; Lee, C. B.; Oh, D. S.; Bang, J. K.; Kim, Y. M.; Yang, Y. S.; Jeong, Y. H.; Jeon, H. K.; Ryu, J. S. [KAERI, Taejon (Korea, Republic of)

    2002-05-01

    Non-instrumental capsule were designed and fabricated to irradiate the advanced pellet developed for the high burn-up LWR fuel in the HANARO in-pile capsule. This capsule was out-pie tested at Cold Test Loop-I in KAERI. From the pressure drop test results, it is noted that the flow velocity across the non-instrumented capsule of advanced PWR fuel pellet corresponding to the pressure drop of 200 kPa is measured to be about 7.45 kg/sec. Vibration frequency for the capsule ranges from 13.0 to 32.3 Hz. RMS displacement for non-instrumented capsule of advanced PWR fuel pellet is less than 11.6 {mu}m, and the maximum displacement is less that 30.5 {mu}m. The flow rate for endurance test were 8.19 kg/s, which was 110% of 7.45 kg/s. And the endurance test was carried out for 100 days and 17 hours. The test results found not to the wear satisfied to the limits of pressure drop, flow rate, vibration and wear in the non-instrumented capsule.

  2. [Dr. Atanasije Puljo: pioneer of Serbian dentistry].

    Science.gov (United States)

    Jovananović, Svetlana; Milovanović, Srdjan; Zagradjanin, Danica; Milovanović, Nebojša; Puzović, Dragana

    2012-01-01

    This paper describes the life and work of Dr. Atanasije Puljo (1878-1944). He was a volunteer in the Balkan wars, an active participant in the First World War; he was the first who noted the importance of team-work of a dentist and a surgeon in the care of jaw and facial injuries. He established primacy in this field, as he came up with this brilliant idea three years before other colleagues. His method of treatment of the upper jaw neglected fractures, called the Balkan method, was recognized worldwide. Dr. Puljo is the pioneer of dental radiology in Serbia, founder of the Odontology Clinic of the Medical Faculty and main supporter of the establishment of the School of Dentistry. Merits of Dr. Atanasije Puljo, medical practitioner with a broad knowledge in different fields, remain within the academic institution that was founded by this pioneer of dentistry in Serbia.

  3. As(III) oxidation by MnO{sub 2} coated PEEK-WC nanostructured capsules

    Energy Technology Data Exchange (ETDEWEB)

    Criscuoli, Alessandra, E-mail: a.criscuoli@itm.cnr.it [Institute on Membrane Technology, ITM-CNR, Via P. Bucci Cubo 17/C, 87030 Rende (CS) (Italy); Majumdar, Swachchha [Central Glass and Ceramic Research Institute, 196, Raja S. C. Mullick Rd., 700032 Kolkata (India); Figoli, Alberto, E-mail: a.figoli@itm.cnr.it [Institute on Membrane Technology, ITM-CNR, Via P. Bucci Cubo 17/C, 87030 Rende (CS) (Italy); Sahoo, Ganesh C. [Central Glass and Ceramic Research Institute, 196, Raja S. C. Mullick Rd., 700032 Kolkata (India); Bafaro, Patrizia [Institute on Membrane Technology, ITM-CNR, Via P. Bucci Cubo 17/C, 87030 Rende (CS) (Italy); Department of Chemical Engineering and Materials, University of Calabria, Via P. Bucci Cubo 42/A, 87030 Rende (CS) (Italy); Bandyopadhyay, Sibdas [Central Glass and Ceramic Research Institute, 196, Raja S. C. Mullick Rd., 700032 Kolkata (India); Drioli, Enrico [Institute on Membrane Technology, ITM-CNR, Via P. Bucci Cubo 17/C, 87030 Rende (CS) (Italy); Department of Chemical Engineering and Materials, University of Calabria, Via P. Bucci Cubo 42/A, 87030 Rende (CS) (Italy)

    2012-04-15

    Highlights: Black-Right-Pointing-Pointer Successful preparation of PEEK-WC nanostructured capsules coated by MnO{sub 2}. Black-Right-Pointing-Pointer Preliminary tests of As(III) oxidation carried out in batch. Black-Right-Pointing-Pointer Complete oxidation obtained for feed concentrations of 0.1 and 0.3 ppm. - Abstract: PEEK-WC nanostructured capsules were prepared by the phase inversion technique and used as support for the coating of a manganese dioxide layer. The coating was done by a chemical treatment of the capsules followed by a thermal one. The presence of the MnO{sub 2} layer was confirmed by scanning electron microscopy (SEM), back scattering electron (BSE), energy dispersive X-ray (EDX) and X-ray diffraction (XRD) analysis. The produced capsules were, then, tested for As(III) oxidation in batch. The experiments consisted in treating 165 ml of As(III) solution with 1 g of coated capsules at fixed temperature (15 Degree-Sign C) and pH (5.7-5.8). In particular, the efficiency of the system was investigated for different As(III) concentrations (0.1, 0.3, 0.7 and 1 ppm). For feeds at lower As(III) content (0.1-0.3 ppm), tests lasted for 8 h, while prolonged runs (up to 48 h) were carried out on more concentrated solutions (0.7 and 1 ppm). The produced capsules were able to oxidize As(III) into As(V) leading to complete conversion after 3 and 4 h for feed concentrations of 0.1 and 0.3 ppm, respectively.

  4. Programmed temperature control of capsule in irradiation test with personal computer at JMTR

    International Nuclear Information System (INIS)

    Saito, H.; Uramoto, T.; Fukushima, M.; Obata, M.; Suzuki, S.; Nakazaki, C.; Tanaka, I.

    1992-01-01

    The capsule irradiation facility is one of various equipments employed at the Japan Materials Testing Reactor (JMTR). The capsule facility has been used in irradiation tests of both nuclear fuels and materials. The capsule to be irradiated consists of the specimen, the outer tube and inner tube with a annular space between them. The temperature of the specimen is controlled by varying the degree of pressure (below the atmospheric pressure) of He gas in the annular space (vacuum-controlled). Beside this, in another system the temperature of the specimen is controlled with electric heaters mounted around the specimen (heater-controlled). The use of personal computer in the capsule facility has led to the development of a versatile temperature control system at the JMTR. Features of this newly-developed temperature control system lie in the following: the temperature control mode for a operation period can be preset prior to the operation; and the vacuum-controlled irradiation facility can be used in cooperation with the heater-controlled. The introduction of personal computer has brought in automatic heat-up and cool-down operations of the capsule, setting aside the hand-operated jobs which had been conducted by the operators. As a result of this, the various requirements seeking a higher accuracy and efficiency in the irradiation can be met by fully exploiting the capabilities incorporated into the facility which allow the cyclic or delicate changes in the temperature. This paper deals with a capsule temperature control system with personal computer. (author)

  5. How Dr. Pierce Promoted Himself

    Data.gov (United States)

    Department of the Interior — This article is about Dr. Raymond V Pierce who owned St. Vincent Island before it became a refuge. The doctor painted advertisements for his famous “Woman’s Tonic”...

  6. Preparation of sustained release capsules by electrostatic dry powder coating, using traditional dip coating as reference.

    Science.gov (United States)

    Yang, Yan; Shen, Lian; Yuan, Feng; Fu, Hui; Shan, Weiguang

    2018-05-30

    Lately, a great deal of attention is being paid to capsule coating, since the coat protects active pharmaceutical ingredients (APIs) from damage, as is in the case of tablet and pellet. However, moisture and heat sensitivity of gelatin shells make it challenging to coat capsules using the conventional aqueous coating techniques. In an effort to overcome this challenge, the present study aims to coat capsules using two different coating techniques: electrostatic dry powder coating (EDPC) and dip coating (DC). Both capsule coatings and free films were prepared by these two coating techniques, and the effects of coating formulations and processing conditions on the film quality were investigated. The corresponding drug in vitro release and mechanisms were characterized and compared. The results of dissolution tests demonstrated that the drug release behavior of both EDPC and DC coated capsules could be optimized to a sustained release of 24 h, following the Fick's diffusion law. The results of this study suggest that EDPC method is better than DC method for coating capsules, with respect to the higher production efficiency and better stability, indicating that this dry coating technology has promised in gelatin capsule coating applications. Copyright © 2018 Elsevier B.V. All rights reserved.

  7. Investigation of special capsule technologies for material in-pile irradiation test and development plan in HANARO

    Energy Technology Data Exchange (ETDEWEB)

    Cho, M. S.; Son, J. M.; Kim, D. S.; Park, S. J.; Cho, Y. G.; Seo, C. K.; Kang, Y. H. [KAERI, Taejon (Korea, Republic of)

    2002-10-01

    In-pile test for several materials such as Zr alloy, stainless steel, Cr-Ni steel etc. which are used as structural material of the advanced reactor and KNGR(Korea Next Generation Reactor) like SMART, is necessary to produce the design data for developing new reactor materials. Advanced countries like USA, Europe and Japan etc. are not only performing the simple irradiation test for materials, but developing many kinds of special capsule to perform in-pile test having special purpose. For the special test items of fuel rod, fission products, total heat generation, swelling, deformation, sweep gas, temperature ramping and BOCA etc. are being actively concerned. There are capsules measuring creep, fatigue, crack growth, and controlling fluence etc. for special irradiation test of materials. In addition, the advanced countries are developing several instrument technologies suitable for the special capsules. In HANARO, non-instrumented, instrumented material capsules and non-instrumented fuel capsule have been developed and they have been utilized in the irradiation test for users, and creep capsule loading single specimen was made and is planned to test in the reactor soon. For some forthcoming years, special capsules not only measuring creep deformation with multi-specimens, fatigue, controlling fluence but crack propagation and gas sweep considering the requirements of users will be developed in HANARO.

  8. A performance test of a capsule for a material irradiation in the OR holes of HANARO

    International Nuclear Information System (INIS)

    Cho, M. S.; Choo, K. N.; Shin, Y. T.; Sohn, J. M.; Park, S. J.; Kang, Y. H.; Kim, B. G.

    2008-01-01

    A test for a pressure drop and a vibration was performed to develop a material capsule for an irradiation at the OR hole in HANARO. It was analyzed before the test that a diameter of a material capsule for the OR holes should be more than 49mm by an evaluation of a flow rate and pressure drop in theory. According to this estimation, 3 kinds of mock-up capsules with a diameter of 52, 54, 56 mm were made and applied to a pressure drop test. As a result of the pressure drop test, the requirement for a pressure and a flow rate in HANARO was confirmed to be satisfied for the 3 kinds of diameters. The capsules with diameters of 54, 56mm were applied to a vibration test by taking into consideration a receptive capacity of the specimens. The capsule with a diameter of 56mm satisfied the requirement for an allowable limit of the vibration acceleration applied in HANARO. The heat transfer coefficient and the temperature on the surface of a capsule were estimated. As the temperature on the surface of the capsule was calculated to be 43.7 .deg. C, the ONB condition in HANARO was satisfied

  9. In vivo osteogenic differentiation of stem cells inside compartmentalized capsules loaded with co-cultured endothelial cells.

    Science.gov (United States)

    Correia, Clara R; Santos, Tírcia C; Pirraco, Rogério P; Cerqueira, Mariana T; Marques, Alexandra P; Reis, Rui L; Mano, João F

    2017-04-15

    Capsules coated with polyelectrolytes and co-encapsulating adipose stem (ASCs) and endothelial (ECs) cells with surface modified microparticles are developed. Microparticles and cells are freely dispersed in a liquified core, responsible to maximize the diffusion of essential molecules and allowing the geometrical freedom for the autonomous three-dimensional (3D) organization of cells. While the membrane wraps all the instructive cargo elements within a single structure, the microparticles provide a solid 3D substrate for the encapsulated cells. Our hypothesis is that inside this isolated biomimetic 3D environment, ECs would lead ASCs to differentiate into the osteogenic lineage to ultimately generate a mineralized tissue in vivo. For that, capsules encapsulating only ASCs (MONO capsules) or co-cultured with ECs (CO capsules) are subcutaneously implanted in nude mice up to 6weeks. Capsules implanted immediately after production or after 21days of in vitro osteogenic stimulation are tested. The most valuable outcome of the present study is the mineralized tissue in CO capsules without in vitro pre-differentiation, with similar levels compared to the pre-stimulated capsules in vitro. We believe that the proposed bioencapsulation strategy is a potent self-regulated system, which might find great applicability in bone tissue engineering. The diffusion efficiency of essential molecules for cell survival is a main issue in cell encapsulation. Former studies reported the superior biological outcome of encapsulated cells within liquified systems. However, most cells used in TE are anchorage-dependent, requiring a solid substrate to perform main cellular processes. We hypothesized that liquified capsules encapsulating microparticles are a promising attempt. Inspired by the multiphenotypic cellular environment of bone, we combine the concept of liquified capsules with co-cultures of stem and endothelial cells. After implantation, results show that co-cultured capsules

  10. Model of the humanoid body for self collision detection based on elliptical capsules

    CSIR Research Space (South Africa)

    Dube, C

    2011-12-01

    Full Text Available . The humanoid body is modeled using elliptical capsules, while the moving segments, i.e. arms and legs, of the humanoid are modeled using circular capsules. This collision detection model provides a good fit to the humanoid body shape while being simple...

  11. Power measurement in the boiling capsules in R2 using delayed neutron detector

    International Nuclear Information System (INIS)

    Roennberg, G.

    1979-03-01

    LWR fuel testing is performed in the R2 reactor by irradiation in both loops and so-called boiling capsules. The loops have forced cooling, and the power can be measured calorimetrically by conventional instrumentation. The boiling capsules have convection cooling, and it has therefore been necessary to develop a special technique for power measurement, the delayed neutron detector (DND). The DND is a pneumatic rabbit system, which activates small uranium samples in the boiling capsules and counts the delayed neutrons for determination of the fission rate. This report describes the equipment used, the procedure of measurement, and the method of evaluation. (atuhor)

  12. [A wireless power transmission system for capsule endoscope].

    Science.gov (United States)

    Xin, Wenhui; Yan, Guozheng; Wang, Wenxing

    2010-06-01

    In order to deliver power to the capsule endoscope, whose position and orientation are always changing when traveling along the alimentary tract, a wireless power transmission system based on electromagnetic coupling was proposed. The system is composed of Helmholtz transmitting coil and three-dimensional receiving coil. Helmholtz coil outside the body generates a uniform magnetic field covering the whole alimentary tract; three-dimensional coil inside retrieves stable power regardless of its position and orientation. The transmitter and receiver were designed and implemented, and the experiments validated the feasibility of the system. The results show that at least 320 mW of usable power can be transmitted to capsule endoscope when its position and orientation are changing at random and the transmitting power is 25W.

  13. Capsule enteroscopy and radiology of the small intestine

    Energy Technology Data Exchange (ETDEWEB)

    Fork, Frans-Thomas [Malmoe University Hospital, Department of Diagnostic Radiology, Malmoe (Sweden); Aabakken, Lars [Rikshospitalet University Hospital, Department of Gastroenterology, Oslo (Norway)

    2007-12-15

    In a very few years, the video capsule for small bowel enteroscopy has gained widespread clinical acceptance. It is readily ingested, disposable, and allows for a complete, low-invasive endoscopic examination of the entire mucosa of the small bowel. It is a patient-friendly method and a first-line procedure in the difficult evaluation of obscure gastrointestinal bleeding. It has the highest proven figure of diagnostic sensitivity for detecting lesions of the mucosa, irrespective of aetiology. The limitations of capsule endoscopy include difficulty in localising mucosal lesions anatomically and its restricted use in patients with dysphagia, strictures or motor dysfunction. Strictures, transmural and extra-mural lesions in patients with small bowel Crohn's disease are evaluated by MRI- enterography and CT-enterography. (orig.)

  14. Postirradiation thermal analysis of capsule P13T

    International Nuclear Information System (INIS)

    Ketterer, J.W.

    1978-12-01

    In determining fuel rod temperature histories for the P13T capsule, a technique which combined measured temperature and dimensional data, TAC-2D computer modeling, and a calculational procedure was employed. TAC-2D models were constructed for each of the capsule's four fuel bodies and temperature matching runs were made at five time points of the irradiation history. The agreement between TAC-calculated and measured temperatures was good; at all times the TAC-calculated temperatures were within 20 0 C of the Chromel-Alumel (C/A) measurements and 40 0 C of the corrected tungsten-rhenium (W/Re) temperatures. Thermocouple decalibration was treated in detail and corrected temperatures for all W/Re thermocouples were calculated over the irradiation period

  15. Capsule enteroscopy and radiology of the small intestine

    International Nuclear Information System (INIS)

    Fork, Frans-Thomas; Aabakken, Lars

    2007-01-01

    In a very few years, the video capsule for small bowel enteroscopy has gained widespread clinical acceptance. It is readily ingested, disposable, and allows for a complete, low-invasive endoscopic examination of the entire mucosa of the small bowel. It is a patient-friendly method and a first-line procedure in the difficult evaluation of obscure gastrointestinal bleeding. It has the highest proven figure of diagnostic sensitivity for detecting lesions of the mucosa, irrespective of aetiology. The limitations of capsule endoscopy include difficulty in localising mucosal lesions anatomically and its restricted use in patients with dysphagia, strictures or motor dysfunction. Strictures, transmural and extra-mural lesions in patients with small bowel Crohn's disease are evaluated by MRI- enterography and CT-enterography. (orig.)

  16. Simulations of laser imprint for Nova experiments and for ignition capsules. Revision 1

    International Nuclear Information System (INIS)

    Weber, S.V.; Glendinning, S.G.; Kalantar, D.H.; Key, M.H.; Remington, B.A.; Rothenberg, J.L.; Wolfrum, E.; Verdon, C.P.; Knauer, J.P.

    1996-12-01

    In direct drive ICF, nonuniformities in laser illumination seed ripples at the ablation front in a process called ''imprint''. These nonuniformities grow during the capsule implosion and, if initially large enough, can penetrate the capsule shell, impede ignition, or degrade burn. Imprint has been simulated for recent experiments performed on the Nova laser at LLNL examining a variety of beam smoothing conditions. Most used laser intensities similar to the early part of an ignition capsule pulse shape, 1 ≅ 10 13 W/cm 2 . The simulations matched most of the measurements of imprint modulation. The effect of imprint upon National Ignition Facility (NIF) direct drive ignition capsules has also been simulated. Imprint is predicted to give modulation comparable to an intrinsic surface finish of ∼10 nm RMS. Modulation growth was examined using the Haan [Phys. Rev. A 39, 5812 (1989)] model, with linear growth factors as a function of spherical harmonic mode number obtained from an analytic dispersion relation. Ablation front amplitudes are predicted to become substantially nonlinear, so that saturation corrections are large. Direct numerical simulations of two-dimensional multimode growth were also performed. The capsule shell is predicted to remain intact, which gives a basis for believing that ignition can be achieved. 27 refs., 10 figs

  17. Non-instrumented capsule design of HANARO irradiation test for the high burn-up large grain UO2 pellets

    International Nuclear Information System (INIS)

    Kim, D. H.; Lee, C. B.; Oh, D. S.

    2001-01-01

    Non-instrumented capsule was designed to irradiate the large grain UO 2 pellet developed for the high burn-up LWR fuel in the HANARO in-pile capsule. UO 2 pelletes will be irradiated up to the burn-up higher than 70 MWD/kgU in HANARO. To irradiate the UO 2 pellets up to the burn-up 70 MWD/kgU, need the time about 60 months and ensure the integrity of non-instrumented capsule for 30 months until replace the new capsule. In addition, to satisfy the safety criteria of HANARO such as prevention of ONB(Onset of Nucleate Boiling), fuel melting and wear damage of the capsule during the long term irradiation, design of the non-instrumented capsule was optimized

  18. High temperature radioisotope capsule

    International Nuclear Information System (INIS)

    Bradshaw, G.B.

    1976-01-01

    A high temperature radioisotope capsule made up of three concentric cylinders, with the isotope fuel located within the innermost cylinder is described. The innermost cylinder has hemispherical ends and is constructed of a tantalum alloy. The intermediate cylinder is made of a molybdenum alloy and is capable of withstanding the pressure generated by the alpha particle decay of the fuel. The outer cylinder is made of a platinum alloy of high resistance to corrosion. A gas separates the innermost cylinder from the intermediate cylinder and the intermediate cylinder from the outer cylinder

  19. Measurements of fuel and ablator ρR in Symmetry-Capsule implosions with the Magnetic Recoil neutron Spectrometer (MRS) on the National Ignition Facility

    Energy Technology Data Exchange (ETDEWEB)

    Gatu Johnson, M., E-mail: gatu@psfc.mit.edu; Frenje, J. A.; Li, C. K.; Séguin, F. H.; Petrasso, R. D. [Plasma Science and Fusion Center, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139 (United States); Bionta, R. M.; Casey, D. T.; Caggiano, J. A.; Hatarik, R.; Khater, H. Y.; Sayre, D. B. [Lawrence Livermore National Laboratory, Livermore, California 94550 (United States); Knauer, J. P.; Sangster, T. C. [Laboratory for Laser Energetics, University of Rochester, Rochester, New York 14623 (United States); Herrmann, H. W. [Los Alamos National Laboratory, Los Alamos, New Mexico 87545 (United States); Kilkenny, J. D. [General Atomics, San Diego, California 92186 (United States)

    2014-11-15

    The Magnetic Recoil neutron Spectrometer (MRS) on the National Ignition Facility (NIF) measures the neutron spectrum in the energy range of 4–20 MeV. This paper describes MRS measurements of DT-fuel and CH-ablator ρR in DT gas-filled symmetry-capsule implosions at the NIF. DT-fuel ρR's of 80–140 mg/cm{sup 2} and CH-ablator ρR's of 400–680 mg/cm{sup 2} are inferred from MRS data. The measurements were facilitated by an improved correction of neutron-induced background in the low-energy part of the MRS spectrum. This work demonstrates the accurate utilization of the complete MRS-measured neutron spectrum for diagnosing NIF DT implosions.

  20. Early onset of diabetes in the proband is the major determinant of risk in HLA DR3-DQ2/DR4-DQ8 siblings.

    Science.gov (United States)

    Gillespie, Kathleen M; Aitken, Rachel J; Wilson, Isabel; Williams, Alistair J K; Bingley, Polly J

    2014-03-01

    Islet autoimmunity is initiated in infancy, and primary prevention trials require children at high genetic risk to be identified before autoantibodies appear. To inform screening strategies, we evaluated risks of autoimmunity and diabetes associated with HLA DR3-DQ2/DR4-DQ8 in U.K. families. Extended HLA haplotypes were determined in 2,134 siblings from the Bart's-Oxford Study followed to a median age of 22 years. Risks of diabetes and islet autoimmunity (more than two antibodies) were estimated by survival analysis. Of 138 informative DR3-DQ2/DR4-DQ8 siblings, 63% shared both haplotypes with their diabetic proband, 29% shared one, and 8% shared neither. In HLA-identical DR3-DQ2/DR4-DQ8 siblings, the cumulative risk of diabetes by age 15 was 17% (vs. 6% in those sharing one haplotype or none; P = 0.095). Risk varied, however, with the age at the onset of diabetes in the proband; the cumulative risk of autoimmunity and/or diabetes by age 15 was 61% in siblings of probands diagnosed when younger than 10 years old compared with only 4.7% in those diagnosed after age 10 years (P sibling risk. This suggests that non-HLA genes or epigenetic/environmental factors that accelerate the progression of type 1 diabetes in the proband strongly affect risk in siblings.

  1. Out-pile test of the capsule with cone shape bottom structures

    Energy Technology Data Exchange (ETDEWEB)

    Choi, M. H.; Kang, Y. H.; Cho, M. S.; Choo, K. N.; Kim, B. G.; Son, J. M.; Park, S. J.; Shin, Y. T.; Oh, J. M

    2004-01-01

    The design modification of bottom guide structures for the instrumented capsule which is used for the irradiation test in the research reactor, HANARO is done because of the cutting trouble of the bottom guide arm's pin. The previous structure of the 3-pin arm shape is changed into one body of the cone shape. The specimens of the bottom end cap ring with three different sizes ({phi}68mm, {phi}70mm, {phi}72mm) are designed and manufactured. The out-pile test for the capsule with previous 3-pin arm and new three bottom structures of the cone shape is performed using the one-channel flow test facilities. In order to estimate the compatibility with HANARO, the structural stability and integrity of the capsule, the out-pile test such as a loading/unloading test, a pressure drop test, a thermal performance test, a displacement measurement due to a vibration and an endurance test etc. is conducted, and the outer diameter of the bottom end cap ring to meet the HANARO requirements is selected. From out-pile test results the capsule with cone shape bottom structures is evaluated as to have the structural stability and the benefit from the fluid's flow respect. Also the size satisfied various requirements among three kinds of bottom end cap rings is 70mm in diameter. It is expected that the new bottom structures of the cone shape with 70mm in diameter will be applicable to all material and special capsules which will be designed and manufactured for the purpose of irradiation tests in the future.

  2. Should pediatric patients wait for HLA-DR-matched renal transplants?

    Science.gov (United States)

    Gritsch, H A; Veale, J L; Leichtman, A B; Guidinger, M K; Magee, J C; McDonald, R A; Harmon, W E; Delmonico, F L; Ettenger, R B; Cecka, J M

    2008-10-01

    Graft survival rates from deceased donors aged 35 years or less among all primary pediatric kidney transplant recipients in the United States between 1996 and 2004 were retrospectively examined to determine the effect of HLA-DR mismatches on graft survival. Zero HLA-DR-mismatched kidneys had statistically comparable 5-year graft survival (71%), to 1-DR-mismatched kidneys (69%) and 2-DR-mismatched kidneys (71%). When compared to donors less than 35 years of age, the relative rate of allograft failure was 1.32 (p = 0.0326) for donor age greater than or equal to age 35. There was no statistical increase in the odds of developing a panel-reactive antibody (PRA) greater than 30% at the time of second waitlisting, based upon the degree of HLA-A, -B or -DR mismatch of the first transplant, nor was there a 'dose effect' when more HLA antigens were mismatched between the donor and recipient. Therefore, pediatric transplant programs should utilize the recently implemented Organ Procurement and Transplantation Network's (OPTN)allocation policy, which prioritizes pediatric recipients to receive kidneys from deceased donors less than 35 years of age, and should not turn down such kidney offers to wait for a better HLA-DR-matched kidney.

  3. Ingestible Wireless Capsule Technology: A Review of Development and Future Indication

    Directory of Open Access Journals (Sweden)

    M. R. Basar

    2012-01-01

    Full Text Available Ingestible wireless capsule endoscopy (WCE is the one and only painless, effective, novel, diagnostic technology for inspecting the entire gastrointestinal (GI tract for various diseases, such as obscure gastrointestinal bleeding (OGIB, tumors, cancer, Crohn’s disease, and celiac disease. Since the development of this technology, several companies have made remarkable improvements in their clinical products, but there are still some limitations that relate to the use of conventional wired endoscopy. Some of the major limitations that currently impede its wider application include its inability to repeat the view of critical areas, working time constraints, and poor image resolution. Many research groups currently are working on ways to solve these limitations. Presently, developing the ability to control the movement of the capsule, increasing its image transmission speed, and obtaining high-quality images are the main issues in the research area. A complex capsule with some therapeutic tools for the treatment of diseases of the GI tract also is at the beginning of development for the next generation of an active medical robot. In this paper, we report the status of several activities related to WCE, including improvement of capsule technology, research progress, technical challenges, and key indicators concerning the next-generation, active, medical robot.

  4. Dr. David Sawyer, Mickey Mouse and Dr. David Brown attend a ceremony at Ronald McNair Middle School

    Science.gov (United States)

    1999-01-01

    Dr. David Sawyer (left), Superintendent of the Brevard County School District, Mickey Mouse, and Dr. David Brown, a NASA astronaut, attend a tribute to NASA astronaut Ronald McNair held in the gymnasium of Ronald McNair Magnet School in Cocoa, Fla. During the tribute, Walt Disney World presented a portrait of McNair to the school, which had previously been renamed for the fallen astronaut. McNair was one of a crew of seven who lost their lives during an accident following launch of the Space Shuttle Challenger in January 1986.

  5. Sirsat, Dr Satyavati Motiram

    Indian Academy of Sciences (India)

    Sirsat, Dr Satyavati Motiram Ph.D. (Mumbai). Date of birth: 7 October 1925. Date of death: 10 July 2010. Specialization: Medical Research (Cancer) & Ultrastructural Pathology and Hospice Care of the Dying Last known address: Bhagirathi Sadan, 17th Road, Khar, Mumbai 400 052. YouTube · Twitter · Facebook · Blog ...

  6. David, Dr Joy Caesarina

    Indian Academy of Sciences (India)

    Home; Fellowship. Fellow Profile. Elected: 1982 Section: Medicine. David, Dr Joy Caesarina M.B.B.S., M.S. (Madras). Date of birth: 3 May 1927. Date of death: 20 April 2004. Specialization: Neuropharmacology Last known address: 292, 4th Main, 1st Block, Koramangala, Bengaluru 560 034. YouTube; Twitter; Facebook ...

  7. Asymmetric-shell ignition capsule design to tune the low-mode asymmetry during the peak drive

    International Nuclear Information System (INIS)

    Gu, Jianfa; Dai, Zhensheng; Song, Peng; Zou, Shiyang; Ye, Wenhua; Zheng, Wudi; Gu, Peijun; Wang, Jianguo; Zhu, Shaoping

    2016-01-01

    The low-mode radiation flux asymmetry in the hohlraum is a main source of performance degradation in the National Ignition Facility (NIF) implosion experiments. To counteract the deleterious effects of the large positive P2 flux asymmetry during the peak drive, this paper develops a new tuning method called asymmetric-shell ignition capsule design which adopts the intentionally asymmetric CH ablator layer or deuterium-tritium (DT) ice layer. A series of two-dimensional implosion simulations have been performed, and the results show that the intentionally asymmetric DT ice layer can significantly improve the fuel ρR symmetry, hot spot shape, hot spot internal energy, and the final neutron yield compared to the spherical capsule. This indicates that the DT asymmetric-shell capsule design is an effective tuning method, while the CH ablator asymmetric-shell capsule could not correct the fuel ρR asymmetry, and it is not as effective as the DT asymmetric-shell capsule design.

  8. Asymmetric-shell ignition capsule design to tune the low-mode asymmetry during the peak drive

    Science.gov (United States)

    Gu, Jianfa; Dai, Zhensheng; Song, Peng; Zou, Shiyang; Ye, Wenhua; Zheng, Wudi; Gu, Peijun; Wang, Jianguo; Zhu, Shaoping

    2016-08-01

    The low-mode radiation flux asymmetry in the hohlraum is a main source of performance degradation in the National Ignition Facility (NIF) implosion experiments. To counteract the deleterious effects of the large positive P2 flux asymmetry during the peak drive, this paper develops a new tuning method called asymmetric-shell ignition capsule design which adopts the intentionally asymmetric CH ablator layer or deuterium-tritium (DT) ice layer. A series of two-dimensional implosion simulations have been performed, and the results show that the intentionally asymmetric DT ice layer can significantly improve the fuel ρR symmetry, hot spot shape, hot spot internal energy, and the final neutron yield compared to the spherical capsule. This indicates that the DT asymmetric-shell capsule design is an effective tuning method, while the CH ablator asymmetric-shell capsule could not correct the fuel ρR asymmetry, and it is not as effective as the DT asymmetric-shell capsule design.

  9. Asymmetric-shell ignition capsule design to tune the low-mode asymmetry during the peak drive

    Energy Technology Data Exchange (ETDEWEB)

    Gu, Jianfa, E-mail: gu-jianfa@iapcm.ac.cn; Dai, Zhensheng, E-mail: dai-zhensheng@iapcm.ac.cn; Song, Peng; Zou, Shiyang; Ye, Wenhua; Zheng, Wudi; Gu, Peijun; Wang, Jianguo; Zhu, Shaoping [Institute of Applied Physics and Computational Mathematics, Beijing 100088 (China)

    2016-08-15

    The low-mode radiation flux asymmetry in the hohlraum is a main source of performance degradation in the National Ignition Facility (NIF) implosion experiments. To counteract the deleterious effects of the large positive P2 flux asymmetry during the peak drive, this paper develops a new tuning method called asymmetric-shell ignition capsule design which adopts the intentionally asymmetric CH ablator layer or deuterium-tritium (DT) ice layer. A series of two-dimensional implosion simulations have been performed, and the results show that the intentionally asymmetric DT ice layer can significantly improve the fuel ρR symmetry, hot spot shape, hot spot internal energy, and the final neutron yield compared to the spherical capsule. This indicates that the DT asymmetric-shell capsule design is an effective tuning method, while the CH ablator asymmetric-shell capsule could not correct the fuel ρR asymmetry, and it is not as effective as the DT asymmetric-shell capsule design.

  10. Use of atomic force microscopy and transmission electron microscopy for correlative studies of bacterial capsules.

    Science.gov (United States)

    Stukalov, Oleg; Korenevsky, Anton; Beveridge, Terry J; Dutcher, John R

    2008-09-01

    Bacteria can possess an outermost assembly of polysaccharide molecules, a capsule, which is attached to their cell wall. We have used two complementary, high-resolution microscopy techniques, atomic force microscopy (AFM) and transmission electron microscopy (TEM), to study bacterial capsules of four different gram-negative bacterial strains: Escherichia coli K30, Pseudomonas aeruginosa FRD1, Shewanella oneidensis MR-4, and Geobacter sulfurreducens PCA. TEM analysis of bacterial cells using different preparative techniques (whole-cell mounts, conventional embeddings, and freeze-substitution) revealed capsules for some but not all of the strains. In contrast, the use of AFM allowed the unambiguous identification of the presence of capsules on all strains used in the present study, including those that were shown by TEM to be not encapsulated. In addition, the use of AFM phase imaging allowed the visualization of the bacterial cell within the capsule, with a depth sensitivity that decreased with increasing tapping frequency.

  11. Mg II ABSORPTION CHARACTERISTICS OF A VOLUME-LIMITED SAMPLE OF GALAXIES AT z ∼ 0.1

    International Nuclear Information System (INIS)

    Barton, Elizabeth J.; Cooke, Jeff

    2009-01-01

    We present an initial survey of Mg II absorption characteristics in the halos of a carefully constructed, volume-limited subsample of galaxies embedded in the spectroscopic part of the Sloan Digital Sky Survey (SDSS). We observed quasars near sightlines to 20 low-redshift (z ∼ 0.1), luminous (M r + 5log h ≤-20.5) galaxies in SDSS DR4 and DR6 with the LRIS-B spectrograph on the Keck I telescope. The primary systematic criteria for the targeted galaxies are a redshift z ∼> 0.1 and the presence of an appropriate bright background quasar within a projected 75 h -1 kpc of its center, although we preferentially sample galaxies with lower impact parameters and slightly more star formation within this range. Of the observed systems, six exhibit strong (W eq (2796) ≥ 0.3 A) Mg II absorption at the galaxy's redshift, six systems have upper limits which preclude strong Mg II absorption, while the remaining observations rule out very strong (W eq (2796) ≥ 1-2 A) absorption. The absorbers fall at higher impact parameters than many non-absorber sightlines, indicating a covering fraction f c ∼ -1 kpc (f c ∼ 0.25). The data are consistent with a possible dependence of covering fraction and/or absorption halo size on the environment or star-forming properties of the central galaxy.

  12. Dr. Mostafa Moin, Minister of Science, Research and Technology, Islamic Republic of Iran

    CERN Multimedia

    Patrice Loïez

    2001-01-01

    L. to. r.:Dr Henrik Foeth, Team Leader, CMS experiment; Dr Daniel Denegri, Physics Coordinator, CMS experiment; Prof. Tejinder Virdee, Deputy Spokesman, CMS experiment; Prof. Luciano Maiani, CERN Director-General (signing); Mr Jean-Marie Dufour, Head of the Legal Service, Mr Ghodratollah Habibpour Gharakol (back); Dr Abdolali Sharghi, Advisor to the Minister and Director General, Office of International Scientific Cooperation, Ministry of Science, Research and Technology; Dr Mostafa Moin, Minister of Science, Research and Technology, Islamic Republic of Iran (signing); Dr Reza Mansouri, Director, International Scientific Meetings Office, Ministry of Science, Research and Technology; H. E. Dr Ali Khorram, Extraordinary and plenipotentiary Ambassador to the United Nations in Geneva and Dr Hans F. Hoffmann, CERN Director for Technology Transfer & for Scientific Computing. _

  13. 3D magnetic-resonance-coupling (MRC) localization of wireless capsule endoscopy

    DEFF Research Database (Denmark)

    Xia, Yongming; Zhang, Lihui; Lu, Kaiyuan

    2016-01-01

    ) technique, which has been widely developed for efficient wireless power transfer, is introduced. It is proposed that the distance dependent signal strength in a MRC system can be beneficially used for 3D localization. The new 3D-MRC localization system consists of three orthogonal emitting coils which......Wireless Capsule Endoscope (WCE) enables developing actively controlled capsule for potential complex surgeries, imaging, and new medicine tests. These tasks of WCE need safe, efficient, and precise 3D localization techniques. In this paper, a new application of the magnetic resonance coupling (MRC...... are powered by a battery in the capsule, and three pairs of orthogonal receiving coils which are placed outside human body. The distances between the WCE and the receiving coils can be estimated with good accuracy by studying the signal strengths in individual receiving coils. The proposed new 3D...

  14. Abd-Allah, Dr. Adel-Gamil

    African Journals Online (AJOL)

    Abd-Allah, Dr. Adel-Gamil. Vol 12, No 4 (2000) - Articles CORRELATION BETWEEN UTERINE ARTERY FLOW VELOCITY WAVEFORMS AND ENDOMETRIAL HISTOPATHOLOGY IN WOMEN WITH PERIMENOPAUSAL AND POSTMENOPAUSAL BLEEDING. Details. ISSN: 1110-5607. AJOL African Journals Online.

  15. ALARA implementation in 131I therapeutic capsule production facility

    International Nuclear Information System (INIS)

    Kumawat, Lalit; Swaminathan, N.; Sudheer, T.S.; Sachdev, S.S.; Arora, S.S.; Vairalkar, K.G.

    2005-01-01

    Sodium iodide 131 I solution had been invariably administered to patients for both diagnosis and therapy of thyrotoxicosis. The undue exposure to non-target organs has been over come by introducing NaI ( 131 I) in a gelatin capsule. BRIT has set up experimental facility for the preparation and the production volume has augmented into four fold due to increase in demand and the same facility is being used to cater the need. However, the adequately shielded facility (fume hood) used for (manual) dispensing activity in capsules, capsules and product vial capping, transfer of the vials into lead pots and activity measurement of each vial has resulted in significant increase in the personnel exposure. The sources had been identified and efforts were made to reduce the exposure in these operations. An annular shield was introduced around the dispenser, resulted in the reduction of radiation field at wrist level by a factor of three. Introduction of shielded automated dispenser and usage of longer tools for transfer and capping of vials has effected in two times reduction of collective wrist dose. Currently, the relocated capping station two meters away from the source certainly will bring down further exposure. (author)

  16. Application of the UV laser printing technique to soft gelatin capsules containing titanium dioxide in the shells.

    Science.gov (United States)

    Hosokawa, Akihiro; Kato, Yoshiteru

    2012-03-01

    The purpose of this study was to examine application of ultraviolet (UV) laser irradiation to printing soft gelatin capsules containing titanium dioxide (TiO(2)) in the shells and to study effect of UV laser power on the color strength of printing on the soft gelatin capsules. Size 6 Oval type soft gelatin capsules of which shells contained 0.685% TiO(2) and 0.005% ferric dioxide were used in this study. The capsules were irradiated pulsed UV laser at a wavelength 355 nm. The color strength of the printed capsules was determined by a spectrophotometer as total color difference (dE). The soft gelatin capsules which contained TiO(2) in the shells could be printed gray by the laser. Many black particles, which were associated with the printing, were formed at the colored parts of the shells. It was found that there were two inflection points in relationship between output laser energy of a pulse and dE. Below the lower point, the capsules were not printed. From the lower point to the upper point, the capsules were printed gray and total color difference of the printing increased linearly in proportion with the output laser energy. Beyond the upper point, total color difference showed saturation because of micro-bubbles formation at the laser irradiated spot. Soft gelatin capsules containing TiO(2) in the shells could be performed stable printing using the UV laser printing technique. Color strength of the printing could be controlled by regulating the laser energy between the two inflection points.

  17. Deformation of a Capsule in a Power-Law Shear Flow

    Directory of Open Access Journals (Sweden)

    Fang-Bao Tian

    2016-01-01

    Full Text Available An immersed boundary-lattice Boltzmann method is developed for fluid-structure interactions involving non-Newtonian fluids (e.g., power-law fluid. In this method, the flexible structure (e.g., capsule dynamics and the fluid dynamics are coupled by using the immersed boundary method. The incompressible viscous power-law fluid motion is obtained by solving the lattice Boltzmann equation. The non-Newtonian rheology is achieved by using a shear rate-dependant relaxation time in the lattice Boltzmann method. The non-Newtonian flow solver is then validated by considering a power-law flow in a straight channel which is one of the benchmark problems to validate an in-house solver. The numerical results present a good agreement with the analytical solutions for various values of power-law index. Finally, we apply this method to study the deformation of a capsule in a power-law shear flow by varying the Reynolds number from 0.025 to 0.1, dimensionless shear rate from 0.004 to 0.1, and power-law index from 0.2 to 1.8. It is found that the deformation of the capsule increases with the power-law index for different Reynolds numbers and nondimensional shear rates. In addition, the Reynolds number does not have significant effect on the capsule deformation in the flow regime considered. Moreover, the power-law index effect is stronger for larger dimensionless shear rate compared to smaller values.

  18. Poda drástica de verão e produção de cultivares de amoreira-preta em região subtropical

    Directory of Open Access Journals (Sweden)

    Maraisa Hellen Tadeu

    2015-02-01

    Full Text Available O objetivo deste trabalho foi avaliar o manejo de podas em cultivares de amoreira-preta (Rubus spp., submetidas à poda drástica de verão, em regiões subtropicais. O experimento foi conduzido em blocos ao acaso, em arranjo fatorial 2x7 (podas x cultivares, no Município de Lavras, MG. Foram utilizadas as cultivares Comanche, Caingangue, Choctaw, Tupy, Guarani, Brazos e Cherokee, que receberam poda convencional (controle e poda drástica de verão. Foram avaliados dados fenológicos, vegetativos e produtivos nos ciclos de produção 2012/2013 e 2013/2014, além de características físico-químicas dos frutos e da incidência de doenças, no último ciclo de produção. A poda drástica de verão aumenta a produção das cultivares em regiões subtropicais. Não há diferença na qualidade dos frutos colhidos de plantas submetidas aos sistemas de poda avaliados. A poda drástica de verão não é eficiente na redução ou no controle de doenças.

  19. Effects of Tang Mai Kang Capsule on Angioneurotic Lesions in Alloxan-Induced Diabetic Mice

    Institute of Scientific and Technical Information of China (English)

    李华; 王军; 高丽君; 郭永成

    2004-01-01

    The effects of Tang Mai Kang Capsule (糖脉康胶囊) on blood sugar level, gangrene of the tail-tip, pain threshold and learning and memory abilities were investigated in alloxan-induced diabetic mice. The results showed that Tang Mai Kang Capsule could significantly decrease blood sugar level and incidence rate of gangrene of the tail-tip, increase pain threshold, and strengthen learning and memory abilities, suggesting that Tang Mai Kang Capsule functions to decrease blood sugar level and improve the complicated angioneurotic lesions of diabetes.

  20. Benchmarking uranyl peroxide capsule chemistry in organic media

    Energy Technology Data Exchange (ETDEWEB)

    Neal, Harrison A.; Nyman, May [Department of Chemistry, Oregon State University, Corvallis, OR (United States); Szymanowski, Jennifer; Fein, Jeremy B.; Burns, Peter C. [Department of Civil and Environmental Engineering and Earth Sciences, University of Notre Dame, Notre Dame, IN (United States)

    2017-01-03

    Uranyl peroxide capsules are a recent addition to polyoxometalate (POM) chemistry. Ten years of development has ensued only in water, while transition metal POMs are commonly exploited in aqueous and organic media, controlled by counterions or ligation to render the clusters hydrophilic or hydrophobic. Here, new uranyl POM behavior is recognized in organic media, including (1) stabilization and immobilization of encapsulated hydrophilic countercations, identified by Li nuclear magnetic resonance (NMR) spectroscopy, (2) formation of new cluster species upon phase transfer, (3) extraction of uranyl clusters from different starting materials including simulated spent nuclear fuel, (4) selective phase transfer of one cluster type from a mixture, and (5) phase transfer of clusters from both acidic and alkaline media. The capsule morphology of the uranyl POMs renders accurate characterization by X-ray scattering, including the distinction of geometrically similar clusters. Compositional analysis of the aqueous phase post-extraction provided a quantitative determination of the ion exchange process that enables transfer of the clusters into the organic phase. Preferential partitioning of uranyl POMs into organic media presents new frontiers in metal ion behavior and chemical reactions in the confined space of the cluster capsules in hydrophobic media, as well as the reactivity of clusters at the organic/aqueous interface. (copyright 2017 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)