WorldWideScience

Sample records for mev witness beam

  1. Driver-witness electron beam acceleration in dielectric mm-scale capillaries

    Science.gov (United States)

    Lekomtsev, K.; Aryshev, A.; Tishchenko, A. A.; Shevelev, M.; Lyapin, A.; Boogert, S.; Karataev, P.; Terunuma, N.; Urakawa, J.

    2018-05-01

    We investigated a corrugated mm-scale capillary as a compact accelerating structure in the driver-witness acceleration scheme, and suggested a methodology to measure the acceleration of the witness bunch. The accelerating fields produced by the driver bunch and the energy spread of the witness bunch in a corrugated capillary and in a capillary with a constant inner radius were measured and simulated for both on-axis and off-axis beam propagation. Our simulations predicted a change in the accelerating field structure for the corrugated capillary. Also, an approximately twofold increase of the witness bunch energy gain on the first accelerating cycle was expected for both capillaries for the off-axis beam propagation. These results were confirmed in the experiment, and the maximum measured acceleration of 170 keV /m at 20 pC driver beam charge was achieved for off-axis beam propagation. The driver bunch showed an increase in energy spread of up to 11%, depending on the capillary geometry and beam propagation, with a suppression of the longitudinal energy spread in the witness bunch of up to 15%.

  2. NSRL 200 MeV linac beam energy stabilization system

    International Nuclear Information System (INIS)

    Huang Guirong; Pei Yuanji; Dong Sai

    2001-01-01

    By using the computer image processing technology and RF phase auto-shifting system, the ESS (Energy Stabilization System) was applied to 200 MeV Linac. the ESS adjusts beam energy automatically in a range of +-4 MeV. After adjustment beam energy stability is improved to +-6%

  3. MEV Energy Electrostatic Accelerator Ion Beam Emittance Measurement

    OpenAIRE

    I.G. Ignat’ev; M.I. Zakharets; S.V. Kolinko; D.P. Shulha

    2014-01-01

    The testing equipment was designed, manufactured and tried out permitting measurements of total current, current profile and emittance of an ion beam extracted from the ion beam. MeV energy electrostatic accelerator ion H + beam emittance measurement results are presented.

  4. High intensity proton beam transportation through fringe field of 70 MeV compact cyclotron to beam line targets

    Science.gov (United States)

    Zhang, Xu; Li, Ming; Wei, Sumin; Xing, Jiansheng; Hu, Yueming; Johnson, Richard R.; Piazza, Leandro; Ryjkov, Vladimir

    2016-06-01

    From the stripping points, the high intensity proton beam of a compact cyclotron travels through the fringe field area of the machine to the combination magnet. Starting from there the beams with various energy is transferred to the switching magnet for distribution to the beam line targets. In the design of the extraction and transport system for the compact proton cyclotron facilities, such as the 70 MeV in France and the 100 MeV in China, the space charge effect as the beam crosses the fringe field has not been previously considered; neither has the impact on transverse beam envelope coupled from the longitudinal direction. Those have been concerned much more with the higher beam-power because of the beam loss problem. In this paper, based on the mapping data of 70 MeV cyclotron including the fringe field by BEST Cyclotron Inc (BEST) and combination magnet field by China Institute of Atomic Energy (CIAE), the beam extraction and transport are investigated for the 70 MeV cyclotron used on the SPES project at Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali di Legnaro (INFN-LNL). The study includes the space charge effect and longitudinal and transverse coupling mentioned above, as well as the matching of beam optics using the beam line for medical isotope production as an example. In addition, the designs of the ±45° switching magnets and the 60° bending magnet for the extracted beam with the energy from 35 MeV to 70 MeV have been made. Parts of the construction and field measurements of those magnets have been done as well. The current result shows that, the design considers the complexity of the compact cyclotron extraction area and fits the requirements of the extraction and transport for high intensity proton beam, especially at mA intensity levels.

  5. High intensity proton beam transportation through fringe field of 70 MeV compact cyclotron to beam line targets

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Xu, E-mail: emmazhang103@gmail.com [China Institute of Atomic Energy (China); Li, Ming; Wei, Sumin; Xing, Jiansheng; Hu, Yueming [China Institute of Atomic Energy (China); Johnson, Richard R.; Piazza, Leandro; Ryjkov, Vladimir [BEST Cyclotron Inc (Canada)

    2016-06-01

    From the stripping points, the high intensity proton beam of a compact cyclotron travels through the fringe field area of the machine to the combination magnet. Starting from there the beams with various energy is transferred to the switching magnet for distribution to the beam line targets. In the design of the extraction and transport system for the compact proton cyclotron facilities, such as the 70 MeV in France and the 100 MeV in China, the space charge effect as the beam crosses the fringe field has not been previously considered; neither has the impact on transverse beam envelope coupled from the longitudinal direction. Those have been concerned much more with the higher beam-power because of the beam loss problem. In this paper, based on the mapping data of 70 MeV cyclotron including the fringe field by BEST Cyclotron Inc (BEST) and combination magnet field by China Institute of Atomic Energy (CIAE), the beam extraction and transport are investigated for the 70 MeV cyclotron used on the SPES project at Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali di Legnaro (INFN–LNL). The study includes the space charge effect and longitudinal and transverse coupling mentioned above, as well as the matching of beam optics using the beam line for medical isotope production as an example. In addition, the designs of the ±45° switching magnets and the 60° bending magnet for the extracted beam with the energy from 35 MeV to 70 MeV have been made. Parts of the construction and field measurements of those magnets have been done as well. The current result shows that, the design considers the complexity of the compact cyclotron extraction area and fits the requirements of the extraction and transport for high intensity proton beam, especially at mA intensity levels.

  6. Study of tapered glass capillary focusing MeV ion beam

    International Nuclear Information System (INIS)

    Gong Zhiyu; Yan Sha; Ma Hongji; Nie Rui; Xue Jianming; Wang Yugang

    2012-01-01

    In recent years, tapered glass capillary ion beam focusing is developing rapidly. It is attractive for simple, compact, low cost and easy use. However, the focusing mechanism for MeV ion beams is still indistinct. We present several experimental results of focusing 2 MeV He + beam. Ion beams were focused by tapered glass capillaries with various outlet inner diameters from several micron to hundred micron. The current densities, angle divergences and energy spectra of the transmitted ion beams are measured. The results proved that 2 MeV He + ions can focused and guided by our capillaries. The energy spectra show that a great part of transmitted ions experienced obvious energy loss, which is different from results of others research groups. We discussed the reason and charged it to the larger incident angle. Considered the incident ions with larger incident angle, the charge will distribute in a layer of micro meter depth in the capillary’s inner wall, but not the surface. The energy loss and many other spectra characters can be explained in this way.

  7. Simulations of Beam Quality in a 13 MeV PET Cyclotron

    Directory of Open Access Journals (Sweden)

    A. Pramudita

    2015-12-01

    Full Text Available Simulation of the trajectories of negative hydrogen ion (H− beam in a 13 MeV PET cyclotron (DECY-13 were carried out by using the Runge-Kutta (RK4 approximation method and Scilab 5.4.1. The magnetic and electric fields were calculated using Opera-3d/TOSCA softwares at 1 mm resolution. The cyclotron is of a fourth-harmonics type, meaning that the acceleration occurs four times per cycle, with a radiofrequency (RF field of 77.66 MHz frequency and 40 kV amplitude. The calculations and simulations show that the maximum distance between the ion source and the puller is about 6 mm, while the maximum width of the beam at 13 MeV is about 10 mm, and the initial phase between the RF field and the beam ranges from -10° to 10°, with a yield of about 10% of the beam from the ion source getting accelerated to 13 MeV.

  8. CHARACTERIZATION OF 27 MEV PROTON BEAM GENERATED BY TOP-IMPLART LINEAR ACCELERATOR.

    Science.gov (United States)

    De Angelis, C; Ampollini, A; Basile, E; Cisbani, E; Della Monaca, S; Ghio, F; Montereali, R M; Picardi, L; Piccinini, M; Placido, C; Ronsivalle, C; Soriani, A; Strigari, L; Trinca, E; Vadrucci, M

    2018-01-29

    The first proton linear accelerator for tumor therapy based on an actively scanned beam up to the energy of 150 MeV, is under development and construction by ENEA-Frascati, ISS and IFO, under the Italian TOP-IMPLART project. Protons up to the energy of 7 MeV are generated by a customized commercial injector operating at 425 MHz; currently three accelerating modules allow proton delivery with energy up to 27 MeV. Beam homogeneity and reproducibility were studied using a 2D ionizing chamber, EBT3 films, a silicon diode, MOSFETs, LiF crystals and alanine dosimetry systems. Measurements were taken in air with the detectors at ~1 m from the beam line exit window. The maximum energy impinging on the detectors surface was 24.1 MeV, an energy suitable for radiobiological studies. Results showed beam reproducibility within 5% and homogeneity within 4%, on a circular surface of 16 mm in diameter. © The Author(s) 2018. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  9. Development of an MeV ion beam lithography system in Jyvaeskylae

    Energy Technology Data Exchange (ETDEWEB)

    Gorelick, Sergey [Department of Physics, University of Jyvaeskylae, P.O. Box 35, FIN-40014 (Finland)]. E-mail: Sergey.Gorelick@phys.jyu.fi; Ylimaeki, Tommi [Department of Physics, University of Jyvaeskylae, P.O. Box 35, FIN-40014 (Finland); Sajavaara, Timo [Department of Physics, University of Jyvaeskylae, P.O. Box 35, FIN-40014 (Finland); Laitinen, Mikko [Department of Physics, University of Jyvaeskylae, P.O. Box 35, FIN-40014 (Finland); Sagari, A.R.A. [Department of Physics, University of Jyvaeskylae, P.O. Box 35, FIN-40014 (Finland); Whitlow, Harry J. [Department of Physics, University of Jyvaeskylae, P.O. Box 35, FIN-40014 (Finland)

    2007-07-15

    A lithographic facility for writing patterns with ion beams from cyclotron beams is under development for the Jyvaeskylae cyclotron. Instead of focusing and deflecting the beam with electrostatic and magnetic fields a different approach is used. Here a small rectangular beam spot is defined by the shadow of a computer-controlled variable aperture in close proximity to the sample. This allows parallel exposure of rectangular pattern elements of 5-500 {mu}m side with protons up to 6 MeV and heavy ions ({sup 20}Ne, {sup 85}Kr) up to few 100 MeV. Here we present a short overview of the system under construction and development of the aperture design, which is a critical aspect for all ion beam lithography systems.

  10. A standard 9MeV γ beam for detector calibration

    International Nuclear Information System (INIS)

    Troesch-Lasseur, G.; Bermann, F.; Gaulard, M.

    1975-01-01

    A γ capture irradiation device with beam extraction is being developed at Triton. The mean energy in the beam is 9MeV. The beam intensity has been determined from absorbed dose measurements according to ICRU specifications. The maximum dose rate taken as calibration standard is 125+-9rad/h [fr

  11. Beam diagnostics using transition radiation produced by a 100 Mev electron beam

    International Nuclear Information System (INIS)

    Jablonka, M.; Leroy, J.; Hanus, X.; Derost, J.C.; Wartski, L.

    1991-01-01

    We report on several experiments using the optical transition radiation (OTR) produced by a 100 MeV electron beam. In using a sensitive video camera coupled with a digital image processing system an accurate and simple beam profile monitor has been devised. In measuring with a photo-multiplier the radiation emitted in a small solid angle around the direction of the OTR emission, a signal very sensitive to beam energy variations has been obtained. These experiments have been carried out on the Saclay ALS linac

  12. Beam dynamics design of the 211 MeV APT normal conducting linac

    International Nuclear Information System (INIS)

    Young, L.M.; Billen, J.H.; Takeda, H.; Wood, R.L.

    1998-01-01

    This paper describes the normal conducting linac design that is part of the Accelerator for Production of Tritium (APT) project. The new version of PARMILA designed this linac. This linac accepts the beam from the 6.7 MeV radio frequency quadrupole without a separate matching section. At about 10 MeV, it has a smooth transition in the length of period from 8βλ to 9βλ in quadrupole focusing lattice. This adjustment of the period was needed to provide sufficient space for the quadrupole focusing magnets and beam diagnostic equipment. The linac consists of the coupled cavity drift tube linac up to 97 MeV and coupled cavity linac above 97 MeV

  13. Attenuation of 10 MeV electron beam energy to achieve low doses does not affect Salmonella spp. inactivation kinetics

    International Nuclear Information System (INIS)

    Hieke, Anne-Sophie Charlotte; Pillai, Suresh D.

    2015-01-01

    The effect of attenuating the energy of a 10 MeV electron beam on Salmonella inactivation kinetics was investigated. No statistically significant differences were observed between the D 10 values of either Salmonella 4,[5],12:i:- or a Salmonella cocktail (S. 4,[5],12:i:-, Salmonella Heidelberg, Salmonella Newport, Salmonella Typhimurium, Salmonella) when irradiated with either a non-attenuated 10 MeV eBeam or an attenuated 10 MeV eBeam (~2.9±0.22 MeV). The results show that attenuating the energy of a 10 MeV eBeam to achieve low doses does not affect the inactivation kinetics of Salmonella spp. when compared to direct 10 MeV eBeam irradiation. - Highlights: • 10 MeV eBeam energy was attenuated to 2.9±0.22 MeV using HDPE sheets. • Attenuation of eBeam energy does not affect the inactivation kinetics of Salmonella. • Microbial inactivation is independent of eBeam energy in the range of 3–10 MeV

  14. Energy monitoring device for 1.5-2.4 MeV electron beams

    Energy Technology Data Exchange (ETDEWEB)

    Fuochi, P.G., E-mail: fuochi@isof.cnr.i [CNR-ISOF, Via P. Gobetti 101, I-40129 Bologna (Italy); Lavalle, M.; Martelli, A. [CNR-ISOF, Via P. Gobetti 101, I-40129 Bologna (Italy); Kovacs, A. [Institute of Isotopes, HAS, P.O.Box 77, H-1525 Budapest (Hungary); Mehta, K. [Arbeiterstrandbad Strasse 72, Vienna, A-1210 (Austria); Kuntz, F.; Plumeri, S. [Aerial, Parc d' Innovation Rue Laurent Fries F-67400 Illkirch (France)

    2010-03-11

    An easy-to-use and robust energy monitoring device has been developed for reliable detection of day-to-day small variations in the electron beam energy, a critical parameter for quality control and quality assurance in industrial radiation processing. It has potential for using on-line, thus providing real-time information. Its working principle is based on the measurement of currents, or charges, collected by two aluminium absorbers of specific thicknesses (dependent on the beam energy), insulated from each other and positioned within a faraday cup-style aluminium cage connected to the ground. The device has been extensively tested in the energy range of 4-12 MeV under standard laboratory conditions at Institute of Isotopes and CNR-ISOF using different types of electron accelerators; namely, a TESLA LPR-4 LINAC (3-6 MeV) and a L-band Vickers LINAC (7-12 MeV), respectively. This device has been also tested in high power electron beam radiation processing facilities, one equipped with a 7-MeV LUE-8 linear accelerator used for crosslinking of cables and medical device sterilization, and the other equipped with a 10 MeV Rhodotron TT100 recirculating accelerator used for in-house sterilization of medical devices. In the present work, we have extended the application of this method to still lower energy region, i.e. from 1.5 to 2.4 MeV. Also, we show that such a device is capable of detecting deviation in the beam energy as small as 40 keV.

  15. Energy monitoring device for 1.5-2.4 MeV electron beams

    Science.gov (United States)

    Fuochi, P. G.; Lavalle, M.; Martelli, A.; Kovács, A.; Mehta, K.; Kuntz, F.; Plumeri, S.

    2010-03-01

    An easy-to-use and robust energy monitoring device has been developed for reliable detection of day-to-day small variations in the electron beam energy, a critical parameter for quality control and quality assurance in industrial radiation processing. It has potential for using on-line, thus providing real-time information. Its working principle is based on the measurement of currents, or charges, collected by two aluminium absorbers of specific thicknesses (dependent on the beam energy), insulated from each other and positioned within a faraday cup-style aluminium cage connected to the ground. The device has been extensively tested in the energy range of 4-12 MeV under standard laboratory conditions at Institute of Isotopes and CNR-ISOF using different types of electron accelerators; namely, a TESLA LPR-4 LINAC (3-6 MeV) and a L-band Vickers LINAC (7-12 MeV), respectively. This device has been also tested in high power electron beam radiation processing facilities, one equipped with a 7-MeV LUE-8 linear accelerator used for crosslinking of cables and medical device sterilization, and the other equipped with a 10 MeV Rhodotron TT100 recirculating accelerator used for in-house sterilization of medical devices. In the present work, we have extended the application of this method to still lower energy region, i.e. from 1.5 to 2.4 MeV. Also, we show that such a device is capable of detecting deviation in the beam energy as small as 40 keV.

  16. A sub-picosecond pulsed 5 MeV electron beam system

    International Nuclear Information System (INIS)

    Farrell, J. Paul; Batchelor, K.; Meshkovsky, I.; Pavlishin, I.; Lekomtsev, V.; Dyublov, A.; Inochkin, M.; Srinivasan-Rao, T.

    2001-01-01

    Laser excited pulsed, electron beam systems that operate at energies from 1 MeV up to 5 MeV and pulse width from 0.1 to 100 ps are described. The systems consist of a high voltage pulser and a coaxial laser triggered gas or liquid spark gap. The spark gap discharges into a pulse forming line designed to produce and maintain a flat voltage pulse for 1 ns duration on the cathode of a photodiode. A synchronized laser is used to illuminate the photocathode with a laser pulse to produce an electron beam with very high brightness, short duration, and current at or near the space charge limit. Operation of the system is described and preliminary test measurements of voltages, synchronization, and jitter are presented for a 5 MeV system. Applications in chemistry, and accelerator research are briefly discussed

  17. MeV ion-beam analysis of optical data storage films

    Science.gov (United States)

    Leavitt, J. A.; Mcintyre, L. C., Jr.; Lin, Z.

    1993-01-01

    Our objectives are threefold: (1) to accurately characterize optical data storage films by MeV ion-beam analysis (IBA) for ODSC collaborators; (2) to develop new and/or improved analysis techniques; and (3) to expand the capabilities of the IBA facility itself. Using H-1(+), He-4(+), and N-15(++) ion beams in the 1.5 MeV to 10 MeV energy range from a 5.5 MV Van de Graaff accelerator, film thickness (in atoms/sq cm), stoichiometry, impurity concentration profiles, and crystalline structure were determined by Rutherford backscattering (RBS), high-energy backscattering, channeling, nuclear reaction analysis (NRA) and proton induced X-ray emission (PIXE). Most of these techniques are discussed in detail in the ODSC Annual Report (February 17, 1987), p. 74. The PIXE technique is briefly discussed in the ODSC Annual Report (March 15, 1991), p. 23.

  18. First H- beam accelerated at Linac4: 3MeV done, 157 MeV to go!

    CERN Multimedia

    Linac4 Project Team

    2013-01-01

    On 14 November, the first H- (one proton surrounded by two electrons) beam was accelerated to the energy of 3 MeV in the Linac4 - the new linear accelerator that will replace Linac2 as low-energy injector in the LHC accelerator chain.      A view of the Linac4 taken during the recent tests (top image) and the current measured by the instruments at the end of the acceleration line on 14 November (bottom image). Images: Linac4 collaboration. Using the recently installed Radio Frequency Quadrupole (RFQ) accelerator, 13 mA of current were accelerated to the energy of 3 MeV. After the successful commissioning of the Linac4 RFQ at the 3 MeV test stand completed during the first months of 2013, the whole equipment (composed of the RFQ itself, the following Medium Energy Beam Transport line and its diagnostic line) were moved to the Linac4 tunnel during summer and installed in their final position. In the meantime, a new ion source was assembled, installed and successfu...

  19. Measurement of neutron yield by 62 MeV proton beam on a thick beryllium target

    Energy Technology Data Exchange (ETDEWEB)

    Osipenko, M., E-mail: osipenko@ge.infn.it [INFN, sezione di Genova, 16146 Genova (Italy); Ripani, M. [INFN, sezione di Genova, 16146 Genova (Italy); Alba, R. [INFN, Laboratori Nazionali del Sud, 95123 Catania (Italy); Ricco, G. [INFN, sezione di Genova, 16146 Genova (Italy); Schillaci, M. [INFN, Laboratori Nazionali del Sud, 95123 Catania (Italy); Barbagallo, M. [INFN, sezione di Bari, 70126 Bari (Italy); Boccaccio, P. [INFN, Laboratori Nazionali di Legnaro, 35020 Legnaro (Italy); Celentano, A. [Dipartimento di Fisica dell' Università di Genova, 16146 Genova (Italy); Colonna, N. [INFN, sezione di Bari, 70126 Bari (Italy); Cosentino, L.; Del Zoppo, A.; Di Pietro, A. [INFN, Laboratori Nazionali del Sud, 95123 Catania (Italy); Esposito, J. [INFN, Laboratori Nazionali di Legnaro, 35020 Legnaro (Italy); Figuera, P.; Finocchiaro, P. [INFN, Laboratori Nazionali del Sud, 95123 Catania (Italy); Kostyukov, A. [Moscow State University, Moscow 119992 (Russian Federation); Maiolino, C.; Santonocito, D.; Scuderi, V. [INFN, Laboratori Nazionali del Sud, 95123 Catania (Italy); Viberti, C.M. [Dipartimento di Fisica dell' Università di Genova, 16146 Genova (Italy)

    2013-09-21

    The design of a low-power prototype of neutron amplifier recently proposed within the INFN-E project indicated the need for more accurate data on the neutron yield produced by a proton beam with energy of about 70 MeV impinging on a thick beryllium target. Such measurement was performed at the LNS superconducting cyclotron, covering a wide angular range from 0° to 150° and a complete neutron energy interval from thermal to beam energy. Neutrons with energy above 0.5 MeV were measured by liquid scintillators exploiting their time of flight to determine the kinetic energy. For lower energy neutrons, down to thermal energy, a {sup 3}He detector was used. The obtained data are in good agreement with previous measurements at 0° using 66 MeV proton beam, covering neutron energies >10MeV, as well as with measurements at few selected angles using protons of 46, 55 and 113 MeV energy. The present results extend the neutron yield data in the 60–70 MeV beam energy range. A comparison of measured yields to MCNP, FLUKA and Geant4 Monte Carlo simulations was performed.

  20. YAP(Ce) crystal characterization with proton beam up to 60 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Randazzo, N. [Istituto Nazionale di Fisica Nucleare, Sezione di Catania (I), Via S. Sofia, 64-I-95123 Catania (Italy)], E-mail: nunzio.randazzo@ct.infn.it; Sipala, V.; Aiello, S. [Istituto Nazionale di Fisica Nucleare, Sezione di Catania (I), Via S. Sofia, 64-I-95123 Catania (Italy); Lo Presti, D. [Istituto Nazionale di Fisica Nucleare, Sezione di Catania (I), Via S. Sofia, 64-I-95123 Catania (Italy); Dipartimento di Fisica e Astronomia, Universita di Catania, Catania (Italy); Cirrone, G.A.P.; Cuttone, G.; Di Rosa, F. [Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali del Sud (Italy)

    2008-02-21

    A YAP(Ce) crystal was characterized with a proton beam up to 60 MeV. Tests were performed to investigate the possibility of using this detector as a proton calorimeter. The size of the crystal was chosen so that the proton energy is totally lost inside the medium. The authors propose to use the YAP(Ce) crystal in medical applications for proton therapy. In particular, in proton computed tomography (pCT) project it is necessary as a calorimeter in order to measure the proton residual energy after the phantom. Energy resolution, linearity, and light yield were measured in the Laboratori Nazionali del Sud with the CATANA proton beam [ (http://www.lns.infn.it/CATANA/CATANA)] and the results are shown in this paper. The crystal shows a good resolution (3% at 60 MeV proton beam) and it shows good linearity for different proton beam energies (1% at 30-60 MeV energy range). The crystal performances confirm that the YAP(Ce) crystal represents a good solution for these kinds of application.

  1. YAP(Ce) crystal characterization with proton beam up to 60 MeV

    International Nuclear Information System (INIS)

    Randazzo, N.; Sipala, V.; Aiello, S.; Lo Presti, D.; Cirrone, G.A.P.; Cuttone, G.; Di Rosa, F.

    2008-01-01

    A YAP(Ce) crystal was characterized with a proton beam up to 60 MeV. Tests were performed to investigate the possibility of using this detector as a proton calorimeter. The size of the crystal was chosen so that the proton energy is totally lost inside the medium. The authors propose to use the YAP(Ce) crystal in medical applications for proton therapy. In particular, in proton computed tomography (pCT) project it is necessary as a calorimeter in order to measure the proton residual energy after the phantom. Energy resolution, linearity, and light yield were measured in the Laboratori Nazionali del Sud with the CATANA proton beam [ (http://www.lns.infn.it/CATANA/CATANA)] and the results are shown in this paper. The crystal shows a good resolution (3% at 60 MeV proton beam) and it shows good linearity for different proton beam energies (1% at 30-60 MeV energy range). The crystal performances confirm that the YAP(Ce) crystal represents a good solution for these kinds of application

  2. YAP(Ce) crystal characterization with proton beam up to 60 MeV

    Science.gov (United States)

    Randazzo, N.; Sipala, V.; Aiello, S.; Lo Presti, D.; Cirrone, G. A. P.; Cuttone, G.; Di Rosa, F.

    2008-02-01

    A YAP(Ce) crystal was characterized with a proton beam up to 60 MeV. Tests were performed to investigate the possibility of using this detector as a proton calorimeter. The size of the crystal was chosen so that the proton energy is totally lost inside the medium. The authors propose to use the YAP(Ce) crystal in medical applications for proton therapy. In particular, in proton computed tomography (pCT) project it is necessary as a calorimeter in order to measure the proton residual energy after the phantom. Energy resolution, linearity, and light yield were measured in the Laboratori Nazionali del Sud with the CATANA proton beam [ http://www.lns.infn.it/CATANA/CATANA] and the results are shown in this paper. The crystal shows a good resolution (3% at 60 MeV proton beam) and it shows good linearity for different proton beam energies (1% at 30-60 MeV energy range). The crystal performances confirm that the YAP(Ce) crystal represents a good solution for these kinds of application.

  3. Design study of prototype accelerator and MeV test facility for demonstration of 1 MeV, 1 A negative ion beam production

    International Nuclear Information System (INIS)

    Inoue, Takashi; Hanada, Masaya; Miyamoto, Kenji; Ohara, Yoshihiro; Okumura, Yoshikazu; Watanabe, Kazuhiro; Maeno, Shuichi.

    1994-08-01

    In fusion reactors such as ITER, a neutral beam injector of MeV class beam energy and several tens MW class power is required as one of candidates of heating and current drive systems. However, the beam energy of existing high power accelerators are one order of magnitude lower than the required value. In order to realize a neutral beam injector for the fusion reactor, 'Proof-of-Principle' of such high energy acceleration is a critical issue at a reactor relevant beam current and pulse length. An accelerator and an accelerator facility which are necessary to demonstrate the Proof-of-Principle acceleration of negative ion beams up to 1 MeV, have been designed in the present study. The accelerator is composed of a cesium-volume type ion source and a multi-stage electrostatic acceleration system [Prototype Accelerator]. A negative hydrogen ion beam with the current of about one ampere (1 A) can be accelerated up to 1 MeV at a low operating pressure. Two types of acceleration system, a multi-multi type and a multi-single type, have been studied. The test facility has sufficient capability for the test of the Prototype Accelerator [MeV Test Facility]. The dc high voltage generator for negative ion acceleration is a Cockcroft-Walton type and capable of delivering 1 A at 1 MV (=1 MW) for 60 s. High voltage components including Prototype Accelerator are installed in a SF 6 vessel pressurized at 6 kg/cm 2 to overcome high voltage gradients. The vessel and the beamline are installed in a X-ray shield. (author)

  4. Construction of a pulsed MeV positron beam line

    Energy Technology Data Exchange (ETDEWEB)

    Masuno, Shin-ichi; Okada, Sohei; Kawasuso, Atsuo [Japan Atomic Energy Research Inst., Takasaki, Gunma (Japan). Takasaki Radiation Chemistry Research Establishment

    1997-03-01

    To develop a fast (1 MeV) and short pulsed (100 ps) positron beam which enables defect behavior analysis of bulk states of materials even at high temperatures where a usual positron source would melt, we have been performing design study and construction of the beam line in a three-year program since 1994. This report describes the components, design study results and experimental results of the completed parts until now. (author)

  5. Large scale silver nanowires network fabricated by MeV hydrogen (H+) ion beam irradiation

    International Nuclear Information System (INIS)

    S, Honey; S, Naseem; A, Ishaq; M, Maaza; M T, Bhatti; D, Wan

    2016-01-01

    A random two-dimensional large scale nano-network of silver nanowires (Ag-NWs) is fabricated by MeV hydrogen (H + ) ion beam irradiation. Ag-NWs are irradiated under H +  ion beam at different ion fluences at room temperature. The Ag-NW network is fabricated by H + ion beam-induced welding of Ag-NWs at intersecting positions. H +  ion beam induced welding is confirmed by transmission electron microscopy (TEM) and scanning electron microscopy (SEM). Moreover, the structure of Ag NWs remains stable under H +  ion beam, and networks are optically transparent. Morphology also remains stable under H +  ion beam irradiation. No slicings or cuttings of Ag-NWs are observed under MeV H +  ion beam irradiation. The results exhibit that the formation of Ag-NW network proceeds through three steps: ion beam induced thermal spikes lead to the local heating of Ag-NWs, the formation of simple junctions on small scale, and the formation of a large scale network. This observation is useful for using Ag-NWs based devices in upper space where protons are abandoned in an energy range from MeV to GeV. This high-quality Ag-NW network can also be used as a transparent electrode for optoelectronics devices. (paper)

  6. Release the beams! - Linac4 ready to hit the 50 MeV mark

    CERN Multimedia

    Katarina Anthony

    2015-01-01

    The Linac4 accelerator is now prepared to reach 50 MeV. This milestone energy - expected in the coming weeks - will allow the machine to act as a replacement for the ageing Linac2, four years before it takes over at the head of the accelerator chain in 2020.    Inside the Linac4 tunnel, the final DTL cavities will guide beams to 50 MeV.  (Image: Stephan Russenschuck.) The Linac4 accelerator will bring H- ion beams (hydrogen atoms with an extra electron) up to 160 MeV for injection into the PS Booster. As a key part of the LHC injector upgrade programme, Linac4 will allow the PS Booster to double its beam brightness, which will contribute to increasing the LHC’s luminosity. Linac4 will soon bring beams up to 50 MeV - the current energy delivered by the Linac2 accelerator. This milestone follows on from another recent accomplishment: the installation and commissioning of the final Drift Tube Linac (DTL) tank. Using an innovati...

  7. Linac-beam characterizations at 600 MeV using optical transition radiation diagnostics.

    Energy Technology Data Exchange (ETDEWEB)

    Lumpkin, A. H.

    1998-05-27

    Selected optical diagnostics stations were upgraded in anticipation of low-emittance, bright electron beams from a thermionic rf gun or a photoelectric rf gun on the Advanced Photon Source (APS) injector linac. These upgrades include installation of optical transition radiation (OTR) screens, transport lines, and cameras for use in transverse beam size measurements and longitudinal profile measurements. Using beam from the standard thermionic gun, tests were done at 50 MeV and 400 to 650 MeV. Data were obtained on the limiting spatial ({sigma} {approximately} 200 {micro}m) and temporal resolution (300 ms) of the Chromox (Al{sub 2}O{sub 3} : Cr) screen (250-{micro}n thick) in comparison to the OTR screens. Both charge-coupled device (CCD) and charge-injection device (CID) video cameras were used as well as the Hamamatsu C5680 synchroscan streak camera operating at a vertical deflection rate of 119.0 MHz (the 24th subharmonic of the S-band 2856-MHz frequency). Beam transverse sizes as small as {sigma}{sub x} = 60 {micro}m for a 600-MeV beam and micropulse bunch lengths of {sigma}{sub {tau}}<3 ps have been recorded for macropulse-averaged behavior with charges of about 2 to 3 nC per macropulse. These techniques are applicable to linac-driven, fourth-generation light source R and D experiments including the APS's SASE FEL experiment.

  8. The 50 MeV Beam Test Facility at LBL

    International Nuclear Information System (INIS)

    Leemans, W.; Behrsing, G.; Kim, K.J.; Krupnick, J.; Matuk, C.; Selph, F.; Chattopadhyay, S.

    1993-05-01

    A new beam line, expected to be built by September 1993, will transport the 50 MeV electron beam from the ALS LINAC into an experimental area to support various R ampersand D activities in the Center for Beam Physics at LBL. A variety of experiments are planned involving the interaction of such a relativistic electron beam with plasmas (plasma focusing), laser beams (generation of femtosecond X-ray pulses) and electromagnetic cavities (Crab cavities etc....). The beam line is designed using the measured emittance and Twiss parameters of the ALS linac. It accommodates the different requirements of the various experiments on the electron beam properties (charge, energy, pulse length) and on the handling of the beam before and after the interaction point. Special attention has also been given to incorporate diagnostics for measuring the beam properties (such as the electron energy, bunch length and charge) needed in the interpretation of the experiments

  9. Direct determination of k Q factors for cylindrical and plane-parallel ionization chambers in high-energy electron beams from 6 MeV to 20 MeV

    Science.gov (United States)

    Krauss, A.; Kapsch, R.-P.

    2018-02-01

    For the ionometric determination of the absorbed dose to water, D w, in high-energy electron beams from a clinical accelerator, beam quality dependent correction factors, k Q, are required. By using a water calorimeter, these factors can be determined experimentally and potentially with lower standard uncertainties than those of the calculated k Q factors, which are tabulated in various dosimetry protocols. However, one of the challenges of water calorimetry in electron beams is the small measurement depths in water, together with the steep dose gradients present especially at lower energies. In this investigation, water calorimetry was implemented in electron beams to determine k Q factors for different types of cylindrical and plane-parallel ionization chambers (NE2561, NE2571, FC65-G, TM34001) in 10 cm  ×  10 cm electron beams from 6 MeV to 20 MeV (corresponding beam quality index R 50 ranging from 1.9 cm to 7.5 cm). The measurements were carried out using the linear accelerator facility of the Physikalisch-Technische Bundesanstalt. Relative standard uncertainties for the k Q factors between 0.50% for the 20 MeV beam and 0.75% for the 6 MeV beam were achieved. For electron energies above 8 MeV, general agreement was found between the relative electron energy dependencies of the k Q factors measured and those derived from the AAPM TG-51 protocol and recent Monte Carlo-based studies, as well as those from other experimental investigations. However, towards lower energies, discrepancies of up to 2.0% occurred for the k Q factors of the TM34001 and the NE2571 chamber.

  10. Direct determination of k Q factors for cylindrical and plane-parallel ionization chambers in high-energy electron beams from 6 MeV to 20 MeV.

    Science.gov (United States)

    Krauss, A; Kapsch, R-P

    2018-02-06

    For the ionometric determination of the absorbed dose to water, D w , in high-energy electron beams from a clinical accelerator, beam quality dependent correction factors, k Q , are required. By using a water calorimeter, these factors can be determined experimentally and potentially with lower standard uncertainties than those of the calculated k Q factors, which are tabulated in various dosimetry protocols. However, one of the challenges of water calorimetry in electron beams is the small measurement depths in water, together with the steep dose gradients present especially at lower energies. In this investigation, water calorimetry was implemented in electron beams to determine k Q factors for different types of cylindrical and plane-parallel ionization chambers (NE2561, NE2571, FC65-G, TM34001) in 10 cm  ×  10 cm electron beams from 6 MeV to 20 MeV (corresponding beam quality index R 50 ranging from 1.9 cm to 7.5 cm). The measurements were carried out using the linear accelerator facility of the Physikalisch-Technische Bundesanstalt. Relative standard uncertainties for the k Q factors between 0.50% for the 20 MeV beam and 0.75% for the 6 MeV beam were achieved. For electron energies above 8 MeV, general agreement was found between the relative electron energy dependencies of the k Q factors measured and those derived from the AAPM TG-51 protocol and recent Monte Carlo-based studies, as well as those from other experimental investigations. However, towards lower energies, discrepancies of up to 2.0% occurred for the k Q factors of the TM34001 and the NE2571 chamber.

  11. Ion beam induced luminescence from diamond using an MeV ion microprobe

    Energy Technology Data Exchange (ETDEWEB)

    Bettiol, A.A.; Jamieson, D. N.; Prawer, S.; Allen, M.G. [Melbourne Univ., Parkville, VIC (Australia). School of Physics

    1993-12-31

    Analysis of the luminescence induced by a MeV ion beam offers the potential to provide useful information about the chemical properties of atoms in crystals to complement the information provided by more traditional Ion Beam Analysis (IBA) such as Rutherford Backscattering Spectrometry (RBS), ion channeling and Particle Induced X-ray Emission (PIXE). Furthermore, the large penetration depth of the MeV ion beam offers several advantages over the relatively shallow penetration of keV electrons typically employed in cathodoluminescence. An Ion Beam Induced Luminescence (IBIL) detection system was developed for the Melbourne microprobe that allows the spatial mapping of the luminescence signal along with the signals from RBS and PIXE. Homoepitaxial diamond growth has been studied and remarkable shifts in the characteristic blue luminescence of diamond towards the green were observed in the overgrowth. This has been tentatively identified as being due to transition metal inclusions in the epitaxial layers. 8 refs., 2 refs.

  12. Ion beam induced luminescence from diamond using an MeV ion microprobe

    Energy Technology Data Exchange (ETDEWEB)

    Bettiol, A A; Jamieson, D N; Prawer, S; Allen, M G [Melbourne Univ., Parkville, VIC (Australia). School of Physics

    1994-12-31

    Analysis of the luminescence induced by a MeV ion beam offers the potential to provide useful information about the chemical properties of atoms in crystals to complement the information provided by more traditional Ion Beam Analysis (IBA) such as Rutherford Backscattering Spectrometry (RBS), ion channeling and Particle Induced X-ray Emission (PIXE). Furthermore, the large penetration depth of the MeV ion beam offers several advantages over the relatively shallow penetration of keV electrons typically employed in cathodoluminescence. An Ion Beam Induced Luminescence (IBIL) detection system was developed for the Melbourne microprobe that allows the spatial mapping of the luminescence signal along with the signals from RBS and PIXE. Homoepitaxial diamond growth has been studied and remarkable shifts in the characteristic blue luminescence of diamond towards the green were observed in the overgrowth. This has been tentatively identified as being due to transition metal inclusions in the epitaxial layers. 8 refs., 2 refs.

  13. The quasi-monochromatic photon beam used in photoneutron experiments from 20-120 MeV at the 600 MeV Saclay Linac

    International Nuclear Information System (INIS)

    Veyssiere, A.; Beil, H.; Bergere, R.; Carlos, P.; Fagot, J.; Lepretre, A.; Ahrens, J.

    1979-01-01

    A beam of 20-130 MeV positrons, with average intensities between 10 nA and 50 nA, is used at the 600 MeV Saclay Linac to create a quasi-monochromatic photon beam with a continuously variable energy. This beam was used to measure photoneutron cross sections and the corresponding photonuclear facility is first described. The computer-controlled methods, implemented to measure the energy spectrum and the emittance of the positron beam are described. The quasi-monochromatic photon lines are produced by the annihilation in flight of monoenergetic positrons in two annihilation radiators with different Z successively. The photon beam emission angle theta is shown to be the most critical parameter in the search for an optimum overall signal to background ratio for a specific photoneutron experiment. The choice of an angle theta approximately 4 0 is explained for absolute measurements of sigma(γ, xn) cross-sections, for which the used average intensities of monochromatic photons were thus purposely reduced to approximately 5 X 10 3 s -1 , with an energy resolution approximately 12%. (Auth.)

  14. Smith-Purcell radiation from a 50 MeV beam

    Energy Technology Data Exchange (ETDEWEB)

    Brownell, J.H.; Walsh, J. [Dartmouth Coll., Hanover, NH (United States). Dept. of Physics and Astronomy; Kirk, H.G.; Fernow, R.C. [Brookhaven National Lab., Upton, NY (United States). Dept. of Physics; Robertson, S.H. [Univ. of Colorado, Boulder, CO (United States). Dept. of Astrophysics and Geophysics

    1996-10-01

    A 50 MeV electron beam and a 1 mm period, 5{degree} blaze, echelle grating have been used to produce radiation in the mid-infrared spectral region. The emission is highly collimated and forward-directed. The intensity level in the few ps pulse (2 nJ/sr) indicates a degree of coherent enhancement.

  15. Smith-Purcell radiation from a 50 MeV beam

    International Nuclear Information System (INIS)

    Brownell, J.H.; Walsh, J.; Kirk, H.G.; Fernow, R.C.; Robertson, S.H.

    1996-10-01

    A 50 MeV electron beam and a 1 mm period, 5 degree blaze, echelle grating have been used to produce radiation in the mid-infrared spectral region. The emission is highly collimated and forward-directed. The intensity level in the few ps pulse (2 nJ/sr) indicates a degree of coherent enhancement

  16. 200-MeV bremsstrahlung tagged photon beams at Sendai

    International Nuclear Information System (INIS)

    Hirose, K.; Chiba, M.; Inoue, M.; Kanda, H.; Kimura, R.; Kino, K.; Kobayashi, Y.; Konno, O.; Maeda, K.; Miyase, H.; Miyamoto, A.; Ohtsuki, T.; Saito, A.; Suda, T.; Takahashi, K.; Tamae, T.; Terasaki, Y.; Terasawa, T.; Tsubota, H.; Tsuruta, T.; Utoyama, M.; Yuuki, H.; Yamaguchi, Y.; Yamazaki, H.

    2006-01-01

    A new beam line for photonuclear reaction experiments using tagged photons has been constructed to take advantage of the completion of the 1.2-GeV STretcher Booster (STB) ring at the Laboratory of Nuclear Science (LNS), Tohoku University. A photon tagging system was installed at the end of the new beam line. It provides bremsstrahlung tagged photon beams in an energy range from 0.2E 0 to 0.8E 0 MeV at the incident electron energy E 0 with an energy resolution of ΔE/E∼10 -2 . The tagged photon intensity I= 6 photons/s is available for typical photonuclear reaction experiments. We introduce the basic parameters of the tagged photons by showing the commissioning data

  17. Optimisation of 12 MeV electron beam simulation using variance reduction technique

    International Nuclear Information System (INIS)

    Jayamani, J; Aziz, M Z Abdul; Termizi, N A S Mohd; Kamarulzaman, F N Mohd

    2017-01-01

    Monte Carlo (MC) simulation for electron beam radiotherapy consumes a long computation time. An algorithm called variance reduction technique (VRT) in MC was implemented to speed up this duration. This work focused on optimisation of VRT parameter which refers to electron range rejection and particle history. EGSnrc MC source code was used to simulate (BEAMnrc code) and validate (DOSXYZnrc code) the Siemens Primus linear accelerator model with the non-VRT parameter. The validated MC model simulation was repeated by applying VRT parameter (electron range rejection) that controlled by global electron cut-off energy 1,2 and 5 MeV using 20 × 10 7 particle history. 5 MeV range rejection generated the fastest MC simulation with 50% reduction in computation time compared to non-VRT simulation. Thus, 5 MeV electron range rejection utilized in particle history analysis ranged from 7.5 × 10 7 to 20 × 10 7 . In this study, 5 MeV electron cut-off with 10 × 10 7 particle history, the simulation was four times faster than non-VRT calculation with 1% deviation. Proper understanding and use of VRT can significantly reduce MC electron beam calculation duration at the same time preserving its accuracy. (paper)

  18. Microdosimetry of 0.5 to 2.0 MeV electron beams

    International Nuclear Information System (INIS)

    Braby, L.A.; Roesch, W.C.

    1980-08-01

    The energy imparted in microscopic volumes by electron beams with initial energies from 0.5 to 2.0 MeV has been measured at various depths in plastic. The problems associated with measuring energy deposition spectra of low LET radiations are serious, but the potential importance of these measurements in radiation biophysics justifies the effort required to obtain them. Recent results obtained by Goodhead et al. indicate an RBE greater than 2 for 0.3 keV x-rays compared to 250 kV x-rays, and our results with Chlamydomonas reinhardi indicate an RBE of 1.6 for a 1.5 MeV electron beam at a depth of 400 gm/cm 2 in lucite compared to the same beam at the surface. Development of a theory which appears to explain these results in terms of the microscopic distribution of energy deposition has motivated a detailed study of energy deposition spectra for an electron beam attenuated by various thicknesses of lucite. Simulated sites from 0.5 to 1.9 μm in diameter were studied. The values of anti y determined in these single event measurements compare favorably with those calculated from direct measurements of z reported previously. As expected, the means of the distributions increase significantly with increasing depth in an absorber

  19. Theoretical detection limit of PIXE analysis using 20 MeV proton beams

    Science.gov (United States)

    Ishii, Keizo; Hitomi, Keitaro

    2018-02-01

    Particle-induced X-ray emission (PIXE) analysis is usually performed using proton beams with energies in the range 2∼3 MeV because at these energies, the detection limit is low. The detection limit of PIXE analysis depends on the X-ray production cross-section, the continuous background of the PIXE spectrum and the experimental parameters such as the beam currents and the solid angle and detector efficiency of X-ray detector. Though the continuous background increases as the projectile energy increases, the cross-section of the X-ray increases as well. Therefore, the detection limit of high energy proton PIXE is not expected to increase significantly. We calculated the cross sections of continuous X-rays produced in several bremsstrahlung processes and estimated the detection limit of a 20 MeV proton PIXE analysis by modelling the Compton tail of the γ-rays produced in the nuclear reactions, and the escape effect on the secondary electron bremsstrahlung. We found that the Compton tail does not affect the detection limit when a thin X-ray detector is used, but the secondary electron bremsstrahlung escape effect does have an impact. We also confirmed that the detection limit of the PIXE analysis, when used with 4 μm polyethylene backing film and an integrated beam current of 1 μC, is 0.4∼2.0 ppm for proton energies in the range 10∼30 MeV and elements with Z = 16-90. This result demonstrates the usefulness of several 10 MeV cyclotrons for performing PIXE analysis. Cyclotrons with these properties are currently installed in positron emission tomography (PET) centers.

  20. 1-MeV electron beam propagation experiments in neutral gas

    International Nuclear Information System (INIS)

    Greenspan, M.A.; Rose, E.A.

    1984-01-01

    Experiments were performed studying the propagation of a 1-MeV, 10-ns electron beam at currents of 2-8 kA. Propagation was studied in a 7.6-cm-diam glass guide tube, the same tube with a conducting screen inside, and in a 3.4-m-diam chamber. In the guide tube with the screen, ion-focused propagation is observed at low pressures (≤ 40 Pa) with net current equal to beam current. At higher pressures (55-130 Pa), a notch in beam current is observed for pressure time products of ≅ 100 Pa-ns. Between 270 Pa and 1070 Pa, good propagation is again observed with net currents of 50-70% of the beam current. The net current fraction of beam current increases with increasing pressure and with decreasing beam current. At pressure above 1070 Pa, hose instability occurs, and net current nearly equal to beam current is observed. The hose frequency is in reasonable accord with theory. Nose erosion is minimized at pressures for 1000-2000 Pa depending on beam current, and increases at lower and higher pressures

  1. Target irradiation facility and targetry development at 160 MeV proton beam of Moscow linac

    CERN Document Server

    Zhuikov, B L; Konyakhin, N A; Vincent, J

    1999-01-01

    A facility has been built and successfully operated with the 160 MeV proton beam of Moscow Meson factory LINAC, Institute for Nuclear Research (INR) of Russian Academy of Science, Troitsk. The facility was created for various isotope production goals as well as for fundamental nuclear investigations at high intensity beam (100 mu A and more). An important part of the facility targetry system is a high-intensity beam monitoring collimator device. Measurements of the temperature distribution between collimator sectors, cooling water flow and temperature, and the beam current, provide an opportunity to compute beam losses and beam position. The target holder design allows easy insertion by manipulator and simultaneous bombardment of several different targets of various types and forms, and variation of proton energy on each target over a wide range below 160 MeV. The main target utilized for commercial sup 8 sup 2 Sr isotope production is metallic rubidium in a stainless-steel container. A regular wet chemistry ...

  2. Beam dynamics studies of a 30 MeV RF linac for neutron production

    Science.gov (United States)

    Nayak, B.; Krishnagopal, S.; Acharya, S.

    2018-02-01

    Design of a 30 MeV, 10 Amp RF linac as neutron source has been carried out by means of ASTRA simulation code. Here we discuss details of design simulations for three different cases i.e Thermionic , DC and RF photocathode guns and compare them as injectors to a 30 MeV RF linac for n-ToF production. A detailed study on choice of input parameters of the beam from point of view of transmission efficiency and beam quality at the output have been described. We found that thermionic gun isn't suitable for this application. Both DC and RF photocathode gun can be used. RF photocathode gun would be of better performance.

  3. Transmission property and its applications of MeV ion beams with various capillaries

    International Nuclear Information System (INIS)

    Fujita, N; Ishii, K; Ogawa, H

    2012-01-01

    In order to clarify transmission properties of an ion beam extracted with various capillaries into the air, we have measured intensity distributions for the core and the halo components of MeV ion beams using various capillaries. In addition, we have performed in-air-RBS and in-air-PIXE from the point of the application. At the conference, progress report of transmission properties of ion beams with various capillaries and its applications will be presented.

  4. The 270 MeV deuteron beam polarimeter at the Nuclotron Internal Target Station

    Energy Technology Data Exchange (ETDEWEB)

    Kurilkin, P.K. [Joint Institute for Nuclear Research, Dubna (Russian Federation); Moscow State Institute of Radio-engineering Electronics and Automation (Technical University), Moscow (Russian Federation); Ladygin, V.P., E-mail: vladygin@jinr.ru [Joint Institute for Nuclear Research, Dubna (Russian Federation); Moscow State Institute of Radio-engineering Electronics and Automation (Technical University), Moscow (Russian Federation); Uesaka, T. [Center for Nuclear Study, University of Tokyo, Tokyo 113-0033 (Japan); Suda, K. [RIKEN Nishina Center, Saitama (Japan); Gurchin, Yu.V.; Isupov, A.Yu. [Joint Institute for Nuclear Research, Dubna (Russian Federation); Itoh, K. [Department of Physics, Saitama University, Saitama (Japan); Janek, M. [Joint Institute for Nuclear Research, Dubna (Russian Federation); Physics Department, University of Zilina, 010 26 Zilina (Slovakia); Karachuk, J.-T. [Joint Institute for Nuclear Research, Dubna (Russian Federation); Advanced Research Institute for Electrical Engineering, Bucharest (Romania); Kawabata, T. [Center for Nuclear Study, University of Tokyo, Tokyo 113-0033 (Japan); Khrenov, A.N.; Kiselev, A.S.; Kizka, V.A. [Joint Institute for Nuclear Research, Dubna (Russian Federation); Kliman, J. [Institute of Physics of Slovak Academy of Sciences, Bratislava (Slovakia); Krasnov, V.A.; Livanov, A.N. [Joint Institute for Nuclear Research, Dubna (Russian Federation); Institute for Nuclear Research, Moscow (Russian Federation); Maeda, Y. [Kyushi University, Hakozaki (Japan); Malakhov, A.I. [Joint Institute for Nuclear Research, Dubna (Russian Federation); Matousek, V.; Morhach, M. [Institute of Physics of Slovak Academy of Sciences, Bratislava (Slovakia)

    2011-06-21

    A deuteron beam polarimeter has been constructed at the Internal Target Station at the Nuclotron of JINR. The polarimeter is based on spin-asymmetry measurements in the d-p elastic scattering at large angles and the deuteron kinetic energy of 270 MeV. It allows to measure vector and tensor components of the deuteron beam polarization simultaneously.

  5. Beam tracking simulation in the central region of a 13 MeV PET cyclotron

    Science.gov (United States)

    Anggraita, Pramudita; Santosa, Budi; Taufik, Mulyani, Emy; Diah, Frida Iswinning

    2012-06-01

    This paper reports the trajectories simulation of proton beam in the central region of a 13 MeV PET cyclotron, operating with negative proton beam (for easier beam extraction using a stripper foil), 40 kV peak accelerating dee voltage at fourth harmonic frequency of 77.88 MHz, and average magnetic field of 1.275 T. The central region covers fields of 240mm × 240mm × 30mm size at 1mm resolution. The calculation was also done at finer 0.25mm resolution covering fields of 30mm × 30mm × 4mm size to see the effects of 0.55mm horizontal width of the ion source window and the halted trajectories of positive proton beam. The simulations show up to 7 turns of orbital trajectories, reaching about 1 MeV of beam energy. The distribution of accelerating electric fields and magnetic fields inside the cyclotron were calculated in 3 dimension using Opera3D code and Tosca modules for static magnetic and electric fields. The trajectory simulation was carried out using Scilab 5.3.3 code.

  6. Beam-envelope calculations of space-charge loaded beams in MeV dc ion-implantation facilities

    International Nuclear Information System (INIS)

    Urbanus, W.H.; Bannenberg, J.G.; Doorn, S.; Saris, F.W.; Koudijs, R.; Dubbelman, P.; Koelewijn, W.

    1989-01-01

    MeV dc ion accelerators are being developed that can deliver a beam current up to several hundred micro-amperes. At the low-energy part of the accelerator, the beam transport is space-charge dominated rather than emittance dominated. A system of differential equations has been derived, based on the Kapchinski-Vladimirski equations, which describe the envelope of a space-charge loaded ion beam, taking a longitudinal electrical field in an accelerating tube into account. The equations have been used to design the accelerator of a high-current 1 MV heavy-ion implantation facility. Furthermore, the design of a 2 MV accelerator is presented, which is used for analyzing techniques such as RBS and PIXE. Both facilities are based on single-ended Van de Graaff accelerators. (orig.)

  7. Beam dynamics study of a 30 MeV electron linear accelerator to drive a neutron source

    Science.gov (United States)

    Kumar, Sandeep; Yang, Haeryong; Kang, Heung-Sik

    2014-02-01

    An experimental neutron facility based on 32 MeV/18.47 kW electron linac has been studied by means of PARMELA simulation code. Beam dynamics study for a traveling wave constant gradient electron accelerator is carried out to reach the preferential operation parameters (E = 30 MeV, P = 18 kW, dE/E E-gun, pre-buncher, buncher, and 2 accelerating columns. A disk-loaded, on-axis-coupled, 2π/3-mode type accelerating rf cavity is considered for this linac. After numerous optimizations of linac parameters, 32 MeV beam energy is obtained at the end of the linac. As high electron energy is required to produce acceptable neutron flux. The final neutron flux is estimated to be 5 × 1011 n/cm2/s/mA. Future development will be the real design of a 30 MeV electron linac based on S band traveling wave.

  8. A 14-MeV beam-plasma neutron source for materials testing

    International Nuclear Information System (INIS)

    Futch, A.H.; Coensgen, F.H.; Damm, C.C.; Molvik, A.W.

    1989-01-01

    The design and performance of 14-MeV beam-plasma neutron sources for accelerated testing of fusion reactor materials are described. Continuous production of 14-MeV neutron fluxes in the range of 5 to 10 MW/m 2 at the plasma surface are produced by D-T reactions in a two-component plasma. In the present designs, 14-MeV neutrons result from collisions of energetic deuterium ions created by transverse injection of 150-keV deuterium atoms on a fully ionized tritium target plasma. The beam energy, which deposited at the center of the tritium column, is transferred to the warm plasma by electron drag, which flows axially to the end regions. Neutral gas at high pressure absorbs the energy in the tritium plasma and transfers the heat to the walls of the vacuum vessel. The plasma parameters of the neutron source, in dimensionless units, have been achieved in the 2XIIB high-β plasma. The larger magnetic field of the present design permits scaling to the higher energy and density of the neutron source design. In the extrapolation, care has been taken to preserve the scaling and plasma attributes that contributed to equilibrium, magnetohydrodynamic (MHD) stability, and microstability in 2XIIB. The performance and scaling characteristics are described for several designs chosen to enhance the thermal isolation of the two-component plasmas. 11 refs., 3 figs., 3 tabs

  9. Improvement in beam quality of the JAEA AVF cyclotron for focusing heavy-ion beams with energies of hundreds of MeV

    International Nuclear Information System (INIS)

    Kurashima, Satoshi; Miyawaki, Nobumasa; Okumura, Susumu; Oikawa, Masakazu; Yoshida, Ken-ichi; Kamiya, Tomihiro; Fukuda, Mitsuhiro; Satoh, Takahiro; Nara, Takayuki; Agematsu, Takashi; Ishibori, Ikuo; Yokota, Watalu; Nakamura, Yoshiteru

    2007-01-01

    In order to achieve a heavy-ion microbeam with an energy of hundreds of MeV applied to the research fields of biotechnology and materials science, the JAEA AVF cyclotron (K = 110) has been upgraded to provide a high quality beam with a smaller energy spread and a higher current stability. A flat-top (FT) acceleration system of the cyclotron, designed to produce ion beams with an energy spread of ΔE/E ≤ 0.02%, has been developed to reduce chromatic aberrations in the lenses of the focusing microbeam system. The FT acceleration system provides uniform energy gain of the beam by superimposing a fifth-harmonic voltage on the fundamental one. In addition, stabilization of the acceleration rf voltage and the phase were achieved to accelerate the high quality beam and to provide it stably to the microbeam system connected to a cyclotron beam line. In the latest experiment, we have succeeded to accelerate 260 MeV 20 Ne 7+ with an energy spread of 0.05% in FWHM using the FT acceleration system

  10. Production of iodine-123 radiobiological specimen on 25 MeV electron beam

    International Nuclear Information System (INIS)

    Oganesyan, Yu.Ts.; Starodub, G.Ya.; Buklanov, G.V.; Korotkin, Yu.S.; Belov, A.G.

    1988-01-01

    The technique is described and experimental results are presented for production of radioactive specimen-iodine-123 for medical biological investigations. It is shown that in ten hour irradiation of 124 Xe enriched target of 10 g weight by the 25 MeV electron beam at MT-25 microtron short lived 123 I with activity of about 200 mCl can be accumulated. The procedure was developed for extraction of radioactive atoms and preparing the solution that permits to obtain during 1-1.5 h after the end of irradiation the specimen which satisfies all pharmacopeia requirements. It follows from the results that using small-size electron accelerators with the beam energy up to 25 MeV permits to organize economical and large-scale production of high quality radioactive specimen of 123 I for servicing a large region of this country. 14 refs.; 4 figs.; 1 tab

  11. Suitability of some common polymer films for MeV proton beam dosimetry

    International Nuclear Information System (INIS)

    Makkonen-Craig, S.; Paronen, M.; Arstila, K.; Helariutta, K.; Rauhala, E.; Tikkanen, P.

    2005-01-01

    We have been evaluating the efficacy of polymer films for proton beam dosimetry. PE, PS, PVF, PVDF, PFA and FEP films were irradiated with 4.1 and 9.4 MeV protons at a flux of 2.5 x 10 11 cm -2 s -1 and a fluence of 2.5 x 10 13 cm -2 . The perfluorinated films were relatively insensitive to the proton irradiation. The UV absorption of PS displayed significant radiation-induced red shift, but no quantifiable absorption peaks. The strongly absorbing chromophore at 225 nm of irradiated PVDF is too unstable for practical dosimetry. PE has a stable and moderately absorbing radiolytic chromophore at 235 nm, but is transparent in the visible wavelength region. Irradiated PVF absorbs strongly in both UV and visible regions, and its UV absorbance is linearly proportional to the dose over the range of 10-1000 kGy when irradiated with 4.1 MeV protons at a dose rate of 840 Gy s -1 . PVF shows the most potential as multipurpose dosimeter for high resolution profiling of ion beams. Pertinent applications include irradiations that require verification of lateral beam homogeneity

  12. Estimation of the measurement effective point in cylindrical ionization chamber used in electron beams with energies between 6 and 20 MeV

    International Nuclear Information System (INIS)

    Araujo, M.M. de.

    1984-01-01

    The radial displacement was determined in a water phantom for electrons beams at energies from 6 to 20 MeV for three commercial cylindrical ionization chambers of internal diameters varying from 3.5 to 9.0 mm. The chambers were irradiated with the main axis perpendicular to the direction of the beam. A 300 V bias voltage was applied and readings were taken with both polarities. It was observed that, with increasing depth in the water phantom, the radial displacement remains constant for the 8.9 MeV beam, it increases for the 12.6 MeV electrons and decreases for those of 16.8 and 19.7 MeV. A theoretical model was built in order to calculate the displacement of the effective point of measurement. The Fermi-Eyges multiple scattering theory and a retangular beam normalism developed by Jette (1983) for therapeutic electron beam are used. It was found that the radial displacement stays constant with increasing depth and it decreases with increasing average energy of the incident beam. The model also predicts that the displacement is dependent on the chamber radius. The experimental and theoretical results are compared. They show good agreement for 8.9 and 12.6 MeV electrons, while for 16.8 and 19.7 MeV electrons they indicate that modifications in the theoretical model are necessary. (Author) [pt

  13. Comparison of beam simulations with measurements for a 1.25-MeV, CW RFQ

    International Nuclear Information System (INIS)

    Smith, H.V. Jr.; Bolme, G.O.; Sherman, J.D.; Stevens, R.R. Jr.; Young, L.M.; Zaugg, T.J.

    1998-01-01

    The Low-Energy Demonstration Accelerator (LEDA) injector is tested using the Chalk River Injector Test Stand (CRITS) radio-frequency quadrupole (RFQ) as a diagnostic instrument. Fifty-keV, dc proton beams are injected into the 1.25-MeV, CW RFQ and transported to a beamstop. Computer-simulation-code predictions of the expected beam performance are compared with the measured beam currents and beam profiles. Good agreement is obtained between the measurements and the simulations at the 75-mA design RFQ output current

  14. Theoretical study of cylindrical energy analyzers for MeV range heavy ion beam probes

    International Nuclear Information System (INIS)

    Fujisawa, A.; Hamada, Y.

    1993-07-01

    A cylindrical energy analyzer with drift spaces is shown to have a second order focusing for beam incident angle when the deflection angle is properly chosen. The analyzer has a possibility to be applied to MeV range heavy ion beam probes, and will be also available for accurate particle energy measurements in many other fields. (author)

  15. Design of scan-horn and beam extraction window for a 3 MeV electron accelerator

    International Nuclear Information System (INIS)

    Ghodke, S.R.; Acharya, S.; Puthran, G.P.; Majumder, R.; Mittal, K.C.; Mahendra Kumar; Sethi, R.C.

    2003-01-01

    A 3 MeV, 30 kW D.C. electron accelerator is being developed for installation at the Electron Beam Center at Khargar, Navi Mumbai to cater to industrial uses like cable irradiation. This paper describes the design of the scan horn and beam extraction window of this accelerator. (author)

  16. Evaluation of the Shielding Performance for the Hot-cell built in 100-MeV Isotope Beam-line of KOMAC

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jeong Min; Park, Sung Kyun; Min, Yi Sub; Cho, Yong Sub [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    This study describes the structure of the hot-cell constructed in KOMAC for radioisotope production and evaluates the shielding performance for the hot-cell via the radiation shielding ability test. Korea multi-purpose accelerator complex (KOMAC) is currently operating 20-MeV and 100-MeV beam-line one by on. Additional 100-MeV beam-line and target room (TR101) are planned for the purpose of the radioisotope production in this year. The initial goal of the radioisotope production is to produce the radioactive isotopes, Sr-82 or Cu-67, used widely for the diagnosis and treatment of the cancer. In order to produce these radioisotopes mentioned, the proton beam with the energy between 70-MeV and 100- MeV at a beam current of 300 μA is irradiated into a solid target made of ZnO or RbCl. After the irradiation of the proton beam during approximately 100 hours, the radioisotope Sr-82 with the radioactivity amount of about 3.8 Ci or the Cu-67 with the amount of about 2.7 Ci will be produced. Radioisotopes produced though this process should be conveyed from the TR101 target room to the PR101 processing room and then in order to be delivered into the place for the next process step, a hot-cell is necessary. Result of the shielding performance evaluation of the hot-cell for producing radioisotopes shows the necessity of the shield reinforcement using lead material at side of the lead glass window.

  17. Simulation study of neutron production in thick beryllium targets by 35 MeV and 50.5 MeV proton beams

    Science.gov (United States)

    Shin, Jae Won; Park, Tae-Sun

    2017-09-01

    A data-driven nuclear model dedicated to an accurate description of neutron productions in beryllium targets bombarded by proton beams is developed as a custom development that can be used as an add-on to GEANT4 code. The developed model, G4Data(Endf7.1), takes as inputs the total and differential cross section data of ENDF/B-VII.1 for not only the charge-exchange 9Be(p,n)9B reaction which produces discrete neutrons but also the nuclear reactions relevant for the production of continuum neutrons such as 9Be(p,pn)8Be and 9Be(p,n α) 5Li . In our benchmarking simulations for two experiments with 35 MeV and 50.5 MeV proton beams impinged on 1.16 and 1.05 cm thick beryllium targets, respectively, we find that the G4Data(Endf7.1) model can reproduce both the total amounts and the spectral shapes of the measured neutron yield data in a satisfactory manner, while all the considered hadronic models of GEANT4 cannot.

  18. A Faraday Cup with high frequency response for a 200 MeV LINAC proton beam

    International Nuclear Information System (INIS)

    Zucker, M.S.; Bittner, J.W.

    1991-01-01

    The purpose of this device, composed essentially of coaxial line elements, is monitoring, on a per micropulse basis, the beam intensity of a 200 MeV LINAC at the BNL Radiation Effects Facility. The center conductor of the coaxial line acts as a beam stop. The output pulses are suitable for fast timing. 2 refs., 5 figs

  19. Optimization of beam parameters of electron gun for 2.5 MeV/100 kW high power industrial accelerator

    International Nuclear Information System (INIS)

    Pramod, R.; Petwal, V.C.

    2009-01-01

    A 2.5 MeV/100 kW transformer type industrial accelerator is being developed at RRCAT. A Pierce type electron gun consisting of 10 mm diameter LaB 6 disc (indirectly heated) is used as a source of electron beam. The cathode assembly is put on the top of the accelerating structure, which consists of many electrostatic lenses of which the first lens acts as anode of the gun. The quality of the beam injected into the accelerating structure depends on the anode voltage, shape and size of anode and its distance from the cathode. The anode is subjected to variable voltage during the operation of accelerator from energy 1 MeV to 2.5 MeV, which results in variable emittance at the exit of the electron gun. The electron beam from the gun should provide parallel or slightly convergent beam with long focal length and the emittance of the beam at the exit of electron gun should match the beam acceptance limit of the accelerating structure. The EGUN code is used to optimize the shape and size of the anode, its distance from the cathode to achieve above objectives. Our study suggests that the desired beam parameters at the exit of the anode can be obtained by reducing the aperture size of the anode and by applying suitable voltage gradient to the anode. (author)

  20. High efficiency charge recuperation for electron beams of MeV energies

    International Nuclear Information System (INIS)

    MacLachlan, J.A.

    1996-05-01

    Electron cooling of ion beams with energies of some GeV per nucleon requires high-quality electron beams of MeV energies and currents as high as several amperes. The enormous beam power dictates that the beam current be returned to the high voltage terminal which provides the accelerating potential. The beam is returned to a carefully designed collector within the terminal and biased a few kV positive with respect to it. Thus the load on the HV supply is only the accelerating potential times the sum of the beam current loss and the current used to maintain a graded potential on the accelerating structure. If one employs an electrostatic HV supply like a Van de Graaff with maximum charging current of a few hundred microA, the permissible fractional loss is ∼ 10 -4 . During the 15 years or so the concept of medium energy electron cooling has been evolving, the need to demonstrate the practicability of such high efficiency beam recovery has been recognized. This paper will review some experimental tests and further experiments which have been proposed. The design and status are presented for a new re-circulation experiment at 2 MV being carried out by Fermilab at National Electrostatics Corp

  1. Calculated neutron spectrum from 800-MeV protons incident on a copper beam stop

    International Nuclear Information System (INIS)

    Perry, D.G.

    1975-10-01

    A Monte Carlo calculation was performed to obtain the neutron spectrum generated by 800-MeV protons incident on the LAMPF main copper beam stop. The total flux is calculated to be of the order of 10 13 n/cm 2 -sec-mA at full-beam intensity of 1 mA, with flux spectra calculated for angles of 20 0 , 30 0 , 60 0 , 90 0 , 120 0 , and 150 0 . (auth)

  2. Two-section linear direct-current accelerator of 1.2 MeV electrons. Mean beam current of 50 mA

    International Nuclear Information System (INIS)

    Alimov, A.S.; Ermakov, D.I.; Ishkhanov, B.S.; Shvedunov, V.I.; Sakharov, V.P.; Trower, W.P.

    2002-01-01

    The theoretical and experimental results, obtained by simulation, creation and start-up of the two-section linear electron accelerator, are presented. The following beam parameters: beam current of 49 mA, mean energy of 1.2 MeV, of 59 kV, normalized emittance of 11 mm mrad are determined on the basis of the data on the beam dynamics simulation and the accelerating structure optimization. Special attention is paid to the choice of the version of the SHF-supply system of the two-section accelerator. The version of the SHF-supply system, based on the sections phasing, operating in the auto-oscillation model by means of the synchronizing signal from the feedback chain of the first section into the feedback chain of the second section, is considered. The electron beam parameters on the accelerator outlet (beam current - 44 mA, beam energy - 1.15 MeV, beam efficiency - 50.6 kW) proved to be close to the simulation results [ru

  3. Product conveying system for 10 MeV electron beam accelerator for electron beam centre, Kharghar, Navi Mumbai

    International Nuclear Information System (INIS)

    Bandi, L.N.; Lavale, D.S.; Sarma, K.S.S.; Khader, S.A.; Assadullah, M.; Sabharwal, S.

    2003-01-01

    In industrial radiation processing applications using accelerators, product conveying system plays a vital role in exposing the product to high energy electron beam for imparting specified dose to the product and delivering required through puts. The speed of the conveyor corresponds to a definite time of exposure of the product in the radiation zone. Design of suitable conveyor system for a variety of products with differing dose requirements call for a conveyor with wide speed range. This paper discusses the design features of a suitable under beam conveyor system for 10 MeV, 10 kW accelerator for processing a range of products including medical and food products

  4. Focussed MeV ion beam implanted waveguides

    Energy Technology Data Exchange (ETDEWEB)

    Von Bibra, M.L.; Roberts, A.; Nugent, K.; Jamieson, D.N. [Melbourne Univ., Parkville, VIC (Australia). School of Physics

    1996-12-31

    Single mode buried optical waveguides have been fabricated in fused silica by MeV proton implantation using a focussed hydrogen ion beam. The technique has the potential to direct write waveguide devices and produce multi-layered structures, without the need for intermediate steps such as mask fabrication or layered depositions. A micron resolution Confocal Raman Spectrometer has been used to map the distribution of atomic vacancies that forms the waveguiding region. The results are compared with theoretical calculations. Losses of 3 dB cm{sup -1} have been measured in unannealed samples, which decreases to less than 0.5 dB cm{sup -1} after annealing at 500 degrees Celsius. We describe methods for determining the refractive index distribution of single mode buried waveguides from their output intensity distributions via an inversion of the scalar wave equation. (authors). 5 figs.

  5. Focussed MeV ion beam implanted waveguides

    Energy Technology Data Exchange (ETDEWEB)

    Von Bibra, M L; Roberts, A; Nugent, K; Jamieson, D N [Melbourne Univ., Parkville, VIC (Australia). School of Physics

    1997-12-31

    Single mode buried optical waveguides have been fabricated in fused silica by MeV proton implantation using a focussed hydrogen ion beam. The technique has the potential to direct write waveguide devices and produce multi-layered structures, without the need for intermediate steps such as mask fabrication or layered depositions. A micron resolution Confocal Raman Spectrometer has been used to map the distribution of atomic vacancies that forms the waveguiding region. The results are compared with theoretical calculations. Losses of 3 dB cm{sup -1} have been measured in unannealed samples, which decreases to less than 0.5 dB cm{sup -1} after annealing at 500 degrees Celsius. We describe methods for determining the refractive index distribution of single mode buried waveguides from their output intensity distributions via an inversion of the scalar wave equation. (authors). 5 figs.

  6. Heating of a dense plasma with an intense relativistic electron beam: initial observations

    International Nuclear Information System (INIS)

    Montgomery, M.D.; Parker, J.V.; Riepe, K.B.; Sheffield, R.L.

    1981-01-01

    A dense (approx. 10 17 cm -3 ) plasma has been heated via the relativistic two-stream instability using a 3 MeV, intense (5 x 10 5 A/cm 2 ) electron beam. Evidence for heating has been obtained with diamagnetic loops, thin-foil witness plates, and a 2-channel, broad-band soft x-ray detector. Measurements of energy loss from the beam using calorimetry techniques have been attempted. The measured strong dependence of heating on beam transverse temperature and the very short interaction length ( 100 ns after the beam pulse are consistent with a plasma temperature <150 eV and line emission near 80 to 90 eV

  7. Experimental demonstration of dielectric structure based two beam acceleration

    International Nuclear Information System (INIS)

    Gai, W.; Conde, M. E.; Konecny, R.; Power, J. G.; Schoessow, P.; Sun, X.; Zou, P.

    2000-01-01

    We report on the experimental results of the dielectric based two beam accelerator (step-up transformer). By using a single high charge beam, we have generated and extracted a high power RF pulse from a 7.8 GHz primary dielectric structure and then subsequently transferred to a second accelerating structure with higher dielectric constant and smaller transverse dimensions. We have measured the energy change of a second (witness) beam passing through the acceleration stage. The measured gradient is >4 times the deceleration gradient. The detailed experiment of set-up and results of the measurements are dimmed. Future plans for the development of a 100 MeV demonstration accelerator based on this technique is presented

  8. Experimental demonstration of dielectric structure based two beam acceleration.

    Energy Technology Data Exchange (ETDEWEB)

    Gai, W.; Conde, M. E.; Konecny, R.; Power, J. G.; Schoessow, P.; Sun, X.; Zou, P.

    2000-11-28

    We report on the experimental results of the dielectric based two beam accelerator (step-up transformer). By using a single high charge beam, we have generated and extracted a high power RF pulse from a 7.8 GHz primary dielectric structure and then subsequently transferred to a second accelerating structure with higher dielectric constant and smaller transverse dimensions. We have measured the energy change of a second (witness) beam passing through the acceleration stage. The measured gradient is >4 times the deceleration gradient. The detailed experiment of set-up and results of the measurements are dimmed. Future plans for the development of a 100 MeV demonstration accelerator based on this technique is presented.

  9. Confinement of 2,4 MeV deuterons by plasmoids and focalization of electron beams in plasma focus discharges

    International Nuclear Information System (INIS)

    Nardi, V.; Bostick, W.; Prior, W.; Feugeas, J.; Bortolotti, A.

    1982-01-01

    A detailed analysis has been completed on the internal structure of ions and electron beams which are efected, along the system axis, in opposite directions (0 0 and 180 0 ). An image (contact print) of plasmoids which emit MeV deuterons is formed by the deuteron emission and it is revealed by etching deuteron tracks in a target of plastic material (CR-39). Ion-imaging with different energy filters discriminates between tracks of plasmoid ions and tracks of charged products of D-D fusion reactions. Ions-imaging can also discriminate plasmoid deuterons from MeV deuterons of a directed beam. (L.C.) [pt

  10. Ultra high vacuum system of the 3 MeV electron beam accelerator

    International Nuclear Information System (INIS)

    Puthran, G.P.; Jayaprakash, D.; Mishra, R.L.; Ghodke, S.R.; Majumder, R.; Mittal, K.C.; Sethi, R.C.

    2003-01-01

    Full text: A 3 MeV electron beam accelerator is coming up at the electron beam centre, Kharghar, Navi Mumbai. A vacuum of the order of 1x10 -7 mbar is desired in the beam line of the accelerator. The UHV system is spread over a height of 6 meters. The total surface area exposed to vacuum is 65,000 cm 2 and the volume is 200 litres. Distributed pumping is planned, to avoid undesirable vacuum gradient between any two sections of the beam-line. The electron beam is scanned in an area of 6 cms x 100 cms and it comes out of the scan-horn through a titanium foil of 50 micron thick. Hence the vacuum system is designed in such a way that, in the event of foil rupture during beam extraction, the electron gun, accelerating column and the pumps can be protected from sudden air rush. The vacuum in the beam-line can also be maintained in this condition. After changing the foil, scan-horn area can be separately pumped to bring the vacuum level as desired and can be opened to the beam-line. The design, vacuum pumping scheme and the safety aspects are discussed in this paper

  11. MeV single-ion beam irradiation of mammalian cells using the Surrey vertical nanobeam, compared with broad proton beam and X-ray irradiations

    Energy Technology Data Exchange (ETDEWEB)

    Prakrajang, K. [Plasma and Beam Physics Research Facility, Department of Physics and Materials Science, Faculty of Science, Chiang Mai University, Chiang Mai 50200 (Thailand); Faculty of Science, Maejo University, Chiang Mai 50290 (Thailand); Jeynes, J.C.G.; Merchant, M.J.; Kirkby, K.; Kirkby, N. [Surrey Ion Beam Center, Faculty of Engineering and Physical Science, University of Surrey, Guildford Surrey, GU2 7XH (United Kingdom); Thopan, P. [Plasma and Beam Physics Research Facility, Department of Physics and Materials Science, Faculty of Science, Chiang Mai University, Chiang Mai 50200 (Thailand); Yu, L.D., E-mail: yuld@fnrf.science.cmu.ac.th [Plasma and Beam Physics Research Facility, Department of Physics and Materials Science, Faculty of Science, Chiang Mai University, Chiang Mai 50200 (Thailand); Thailand Center of Excellence in Physics, Commission on Higher Education, 328 Si Ayutthaya Road, Bangkok 10400 (Thailand)

    2013-07-15

    Highlights: •Recently completed nanobeam at the Surrey Ion Beam Centre was used. •3.8-MeV single and broad proton beams irradiated Chinese hamster cells. •Cell survival curves were measured and compared with 300-kV X-ray irradiation. •Single ion irradiation had a lower survival part at ultra-low dose. •It implies hypersensitivity, bystander effect and cell cycle phase of cell death. -- Abstract: As a part of a systematic study on mechanisms involved in physical cancer therapies, this work investigated response of mammalian cells to ultra-low-dose ion beam irradiation. The ion beam irradiation was performed using the recently completed nanobeam facility at the Surrey Ion Beam Centre. A scanning focused vertical ion nano-beam was applied to irradiate Chinese hamster V79 cells. The V79 cells were irradiated in two different beam modes, namely, focused single ion beam and defocused scanning broad ion beam of 3.8-MeV protons. The single ion beam was capable of irradiating a single cell with a precisely controlled number of the ions to extremely low doses. After irradiation and cell incubation, the number of surviving colonies as a function of the number of the irradiating ions was measured for the cell survival fraction curve. A lower survival for the single ion beam irradiation than that of the broad beam case implied the hypersensitivity and bystander effect. The ion-beam-induced cell survival curves were compared with that from 300-kV X-ray irradiation. Theoretical studies indicated that the cell death in single ion irradiation mainly occurred in the cell cycle phases of cell division and intervals between the cell division and the DNA replication. The success in the experiment demonstrated the Surrey vertical nanobeam successfully completed.

  12. Study of the beam of the 60MeV LINAC and automation of the accelerator operation

    International Nuclear Information System (INIS)

    Roland, Sixte.

    1975-07-01

    The on-line automation of a Linac depends essentially on a very extensive use of measuring and control devices. In particular, peak currents from 15 mA to 6 A to pulse configuration from 2 μs to 6 ns respectively are continuously monitored by ferrite transformers at the end of each section. A special study of low intensity beams, of the order of 0.1 μA, has also been made by means of transition radiation phenomena which produce visible radiation whenever an electron beam traverses thin metallic foils (5μ). Thus electron energies, beam profile position and energy as well as pulse widths have been measured by appropriately adapted detectors. A precise knowledge of the behavior of the above cited beam characteristics then enabled the linac performances to attain a stability of the order of one per cent over periods of several weeks. The beam monitoring is performed numerically, analogically and by an ''on-off'' system coupled to a mini-computer. If some error is detected in a section one can then replace the fast numerical controls by the slower analogical ones. The beam control is initiated through monitoring data obtained from certain experimental results which in turn affect the beam energy and intensity. A fully automatic operation for a 4 μA beam covering the 28 MeV - 60 MeV energy range has thus been performed by means of an automatic phase control of the last section together with the appropriate automatic adjustment of the associated magnetic guidance system [fr

  13. High-quality beam generation using an RF gun and a 150 MeV microtron

    Science.gov (United States)

    Kuroda, R.; Washio, M.; Kashiwagi, S.; Kobuki, T.; Ben-Zvi, I.; Wang, X. J.; Hori, T.; Sakai, F.; Tsunemi, A.; Urakawa, J.; Hirose, T.

    2000-11-01

    Low-emittance sub-picosecond electron pulses are expected to be used in a wide field, such as free electron laser, laser acceleration, femtosecond X-ray generation by Inverse Compton scattering, pulse radiolysis, etc. In order to produce the low-emittance sub-picosecond electron pulse, we are developing a compact Racetrack Microtron (RTM) with a new 5 MeV injection system adopting a laser photo cathode RF gun (Washio et al., Seventh China-Japan Bilateral Symposium on Radiation Chemistry, October 28, Cengdu, China, 1996). The operation of RTM has been kept under a steady state of beam loading for long pulse mode so far (Washio et al., J. Surf. Sci. Soc. Jpn. 19 (2) (1998) 23). In earlier work (Washio et al., PAC99, March 31, New York, USA, 1999), we have succeeded in the numerical simulation for the case of single short pulse acceleration. Finally, the modified RTM was demonstrated as a useful accelerator for a picosecond electron pulse generation under a transient state of beam loading. In the simulation, a picosecond electron pulse was accelerated to 149.6 MeV in RTM for the injection of 5 MeV electron bunch with a pulse length of 10 ps (FWHM), a charge of 1 nC per pulse, and an emittance of 3 πmm mrad.

  14. Low (50 keV) and medium (∼10 MeV) energy radioactive beams at Louvain-la-Neuve

    International Nuclear Information System (INIS)

    Huyse, M.; Decrock, P.; Dendooven, P.; Reusen, G.; Duppen, P. Van; Wauters, J.

    1991-01-01

    Low energy radioactive beams are produced at the Leuven Isotope Separator On Line (LISOL) facility in Louvain-la-Neuve. The beams are used for standard nuclear spectroscopy studies and for nuclear orientation on line measurements. Since September 1987 a new project has been started up to accelerate radioactive beams to energies in the range of astrophysical interest. A beam of 10 6 13 N ions per seconde with an energy of 8.5 MeV has been produced last June. (author) 11 refs.; 1 fig.; 1 tab

  15. Subnanosecond pulsing of an 1 MeV ELIT electron accelerator by beam deflection

    International Nuclear Information System (INIS)

    Vasserman, S.B.; Kuzenko, V.; Mehnert, R.; Hermann, R.

    1984-01-01

    Operation principle and performance of a beam deflection system developed for subnanosecond pulsing of an 1 MeV ELIT resonance transformer accelerator are described. Using this system a minimum pulse duration of 0.5 ns (FWHM) and a dose per pulse of about 20 Gy were obtained. As an example the fluorescence of cyclohexane excited by the subnanosecond electron pulse was measured. (author)

  16. Beam generation and planar imaging at energies below 2.40 MeV with carbon and aluminum linear accelerator targets.

    Science.gov (United States)

    Parsons, David; Robar, James L

    2012-07-01

    Recent work has demonstrated improvement of image quality with low-Z linear accelerator targets and energies as low as 3.5 MV. In this paper, the authors lower the incident electron beam energy between 1.90 and 2.35 MeV and assess the improvement of megavoltage planar image quality with the use of carbon and aluminum linear accelerator targets. The bending magnet shunt current was adjusted in a Varian linear accelerator to allow selection of mean electron energy between 1.90 and 2.35 MeV. Linac set points were altered to increase beam current to allow experimental imaging in a practical time frame. Electron energy was determined through comparison of measured and Monte Carlo modeled depth dose curves. Planar image CNR and spatial resolution measurements were performed to quantify the improvement of image quality. Magnitudes of improvement are explained with reference to Monte Carlo generated energy spectra. After modifications to the linac, beam current was increased by a factor greater than four and incident electron energy was determined to have an adjustable range from 1.90 MeV to 2.35 MeV. CNR of cortical bone was increased by a factor ranging from 6.2 to 7.4 and 3.7 to 4.3 for thin and thick phantoms, respectively, compared to a 6 MV therapeutic beam for both aluminum and carbon targets. Spatial resolution was degraded slightly, with a relative change of 3% and 10% at 0.20 lp∕mm and 0.40 lp∕mm, respectively, when reducing energy from 2.35 to 1.90 MV. The percentage of diagnostic x-rays for the beams examined here, ranges from 46% to 54%. It is possible to produce a large fraction of diagnostic energy x-rays by lowering the beam energy below 2.35 MV. By lowering the beam energy to 1.90 MV or 2.35 MV, CNR improves by factors ranging from 3.7 to 7.4 compared to a 6 MV therapy beam, with only a slight degradation of spatial resolution when lowering the energy from 2.35 MV to 1.90 MV.

  17. MeV ion beam interaction with polymer films containing cross-linking agents

    International Nuclear Information System (INIS)

    Evelyn, A. L.

    1999-01-01

    Polymer films containing cross linking enhancers were irradiated with MeV alpha particles to determine the effects of MeV ion beam interaction on these materials. The contributed effects from the electronic and nuclear stopping powers were separated by irradiating stacked thin films of polyvinyl chloride (PVC), polystyrene (PS) and polyethersulfone (PES). This layered system allowed most of the effects of the electronic energy deposited to be experienced by the first layers and the last layers to receive most of the effects of the nuclear stopping power. RGA, Raman microprobe analysis, RBS and FTIR measured changes in the chemical structures of the irradiated films. The characterization resolved the effects of the stopping powers on the PVC, PS and PES and the results were compared with those from previously studied polymers that did not contain any cross linking agents

  18. Design and development of 3 MeV, 30 kW DC industrial electron accelerator at Electron Beam Centre, Kharghar

    International Nuclear Information System (INIS)

    Mittal, K.C.; Nanu, K.; Jain, A.

    2006-01-01

    High power electron beam accelerators are becoming an important tool for industrial radiation process applications. Keeping this in mind, a 3 MeV, 10 mA, 30 kW DC industrial electron accelerator has been designed and is in advanced stage of development at Electron Beam Center, Kharghar, Navi Mumbai. The operating range of this accelerator is 1 MeV to 3 MeV with maximum beam current of 10 mA. Electron beam at 5 keV is generated in electron gun with LaB 6 cathode and is injected into accelerating column at a vacuum of 10 -7 torr. After acceleration the beam is scanned and taken out in air through a 100 cm X 7 cm titanium window for radiation processing applications. The high voltage accelerating power supply is based on a capacitive coupled parallel fed voltage multiplier scheme operating at 120 kHz. A 50 kW oscillator feeds power to high voltage multiplier column. The electron gun, accelerating column and high voltage multiplier column are housed in accelerator tank filled with SF 6 gas insulation at 6 kg/cm 2 . The accelerator is located in a RCC building with product conveyor for handling products. A central computerized control system is adopted for operation of the accelerator. Accelerator is in the advance stage of commissioning. Many of the subsystems have been commissioned and tested. This paper describes the design details and current status of the accelerator and various subsystems. (author)

  19. Use of radial self-field geometry for intense pulsed ion beam generation above 6 MeV on Hermes III.

    Energy Technology Data Exchange (ETDEWEB)

    Renk, Timothy Jerome [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Harper-Slaboszewicz, Victor Jozef [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Ginn, William Craig [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Mikkelson, Kenneth A. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Schall, Michael [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Cooper, Gary Wayne [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2012-12-01

    We investigate the generation and propagation of intense pulsed ion beams at the 6 MeV level and above using the Hermes III facility at Sandia National Laboratories. While high-power ion beams have previously been produced using Hermes III, we have conducted systematic studies of several ion diode geometries for the purpose of maximizing focused ion energy for a number of applications. A self-field axial-gap diode of the pinch reflex type and operated in positive polarity yielded beam power below predicted levels. This is ascribed both to power flow losses of unknown origin upstream of the diode load in Hermes positive polarity operation, and to anomalies in beam focusing in this configuration. A change to a radial self-field geometry and negative polarity operation resulted in greatly increased beam voltage (> 6 MeV) and estimated ion current. A comprehensive diagnostic set was developed to characterize beam performance, including both time-dependent and time-integrated measurements of local and total beam power. A substantial high-energy ion population was identified propagating in reverse direction, i.e. from the back side of the anode in the electron beam dump. While significant progress was made in increasing beam power, further improvements in assessing the beam focusing envelope will be required before ultimate ion generation efficiency with this geometry can be completely determined.

  20. Spin Flipping and Polarization Lifetimes of a 270 MeV Deuteron Beam

    International Nuclear Information System (INIS)

    Morozov, V.S.; Crawford, M.Q.; Etienne, Z.B.; Kandes, M.C.; Krisch, A.D.; Leonova, M.A.; Sivers, D.W.; Wong, V.K.; Yonehara, K.; Anferov, V.A.; Meyer, H.O.; Schwandt, P.; Stephenson, E.J.; Przewoski, B. von

    2003-01-01

    We recently studied the spin flipping of a 270 MeV vertically polarized deuteron beam stored in the IUCF Cooler Ring. We swept an rf solenoid's frequency through an rf-induced spin resonance and observed the effect on the beam's vector and tensor polarizations. After optimizing the resonance crossing rate and setting the solenoid's voltage to its maximum value, we obtained a spin-flip efficiency of about 94 ± 1% for the vector polarization; we also observed a partial spin-flip of the tensor polarization. We then used the rf-induced resonance to measure the vector and tensor polarizations' lifetimes at different distances from the resonance; the polarization lifetime ratio τvector/τtensor was about 1.9 ± 0.4

  1. A study on the proton beam energy(50 MeV) measurement and diagnosis (II)

    Energy Technology Data Exchange (ETDEWEB)

    Chae, Jong Suh; Lee, Dong Hoon; Kim, Yoo Suk; Park, Chan Won; Lee, Yong Min; Hong, Sung Suk; Lee, Min Yong; Lee, Ji Sub; Hah, Hang Hoh [Korea Cancer Center Hospital of Korea Atomic Energy Research Institute, Seoul (Korea, Republic of)

    1995-02-01

    The main purpose of this project is the precise ion measurement of proton beam energy extracted at RF 25.89 MHz from the MC-50 cyclotron of SF type. There are several method for particle energy measurement. We measured the 50 MeV proton energy by using the E-{Delta}E method in 1993. And also in our experiment used range, reapproval of energy of extracted proton beam at RF 25.89 MHz was performed, which attained the same energy with the result used elastic scattering within the error range. 10 figs, 2 pix, 3 tabs, 3 refs. (Author).

  2. Dosimetric evaluation of multi-sided irradiation on HDPE pipes under 2 MeV electron beam

    Energy Technology Data Exchange (ETDEWEB)

    Benny, P.G., E-mail: bennypg@yahoo.com; Khader, S.A.; Sarma, K.S.S.

    2014-03-01

    The use of electron beam technology has enabled the production of heat resistant pipe for hot water circulation. One of the difficulties in the irradiation of pipe products is the uneven penetration of electrons. Quality of the radiation process depends on radiation dose and homogeneity of the dose distribution, which becomes a major concern when treatments of circular objects like pipes are performed. One method to achieve uniformity in the absorbed dose in the product is to use multi-sided irradiation. The paper discusses the importance of dosimetry mapping in industrial electron beam radiation processing and outlines the challenges in delivering a uniform dose to cylindrical objects. In this study, HDPE pipe of 5 mm thickness of homogeneous material (40 mm outer diameter and 30 mm inner diameter) has been chosen for multi-sided irradiation under 2 MeV scanned electron beam from the ILU-6 accelerator. - Highlights: • The paper outlines the challenges in delivering uniform dose to cylindrical objects at 2 MeV industrial electron beam facility. • HDPE pipe of 40 mm outer diameter and 30 mm inner diameter has been chosen for the study. • The circumferential dose distribution inside and outside of the pipes were evaluated by using calibrated CTA dosimeter strips. • Using stack of dosimeter strips, changes in circumferential dose distribution in the annular region of the pipe was evaluated. • Optimization of multi-sided irradiation on the HDPE pipes for better dose homogeneity is reported in the paper.

  3. Dosimetric evaluation of multi-sided irradiation on HDPE pipes under 2 MeV electron beam

    International Nuclear Information System (INIS)

    Benny, P.G.; Khader, S.A.; Sarma, K.S.S.

    2014-01-01

    The use of electron beam technology has enabled the production of heat resistant pipe for hot water circulation. One of the difficulties in the irradiation of pipe products is the uneven penetration of electrons. Quality of the radiation process depends on radiation dose and homogeneity of the dose distribution, which becomes a major concern when treatments of circular objects like pipes are performed. One method to achieve uniformity in the absorbed dose in the product is to use multi-sided irradiation. The paper discusses the importance of dosimetry mapping in industrial electron beam radiation processing and outlines the challenges in delivering a uniform dose to cylindrical objects. In this study, HDPE pipe of 5 mm thickness of homogeneous material (40 mm outer diameter and 30 mm inner diameter) has been chosen for multi-sided irradiation under 2 MeV scanned electron beam from the ILU-6 accelerator. - Highlights: • The paper outlines the challenges in delivering uniform dose to cylindrical objects at 2 MeV industrial electron beam facility. • HDPE pipe of 40 mm outer diameter and 30 mm inner diameter has been chosen for the study. • The circumferential dose distribution inside and outside of the pipes were evaluated by using calibrated CTA dosimeter strips. • Using stack of dosimeter strips, changes in circumferential dose distribution in the annular region of the pipe was evaluated. • Optimization of multi-sided irradiation on the HDPE pipes for better dose homogeneity is reported in the paper

  4. 6 MeV pulsed electron beam induced surface and structural changes in polyimide

    Energy Technology Data Exchange (ETDEWEB)

    Mathakari, Narendra L.; Bhoraskar, Vasant N. [Microtron Accelerator Laboratory, Department of Physics, University of Pune, Ganeshkhind, Pune 411007, Maharashtra (India); Dhole, Sanjay D., E-mail: sanjay@physics.unipune.ernet.i [Microtron Accelerator Laboratory, Department of Physics, University of Pune, Ganeshkhind, Pune 411007, Maharashtra (India)

    2010-04-15

    Thin films of polyimide (PMDA-ODA, Kapton) having 50 mum thickness were irradiated with 6 MeV pulsed electron beam. The bulk and surface properties of pristine and irradiated samples were characterized by several techniques such as stress-strain measurements, Fourier Transform Infrared (FTIR), UV-vis spectroscopy, contact angle, atomic force microscopy (AFM) and profilometry. The tensile strength, percentage elongation and strain energy show an enhancement from pristine value of 73-89 MPa, 10-22% and 4.75-14.2 MJ/m{sup 3} respectively at the maximum fluence of 4 x 10{sup 15} electrons/cm{sup 2}. This signifies that polyimide being an excessively aromatic polymer is crosslinked due to high-energy electron irradiation. In surface properties, the contact angle shows a significant decrease from 59 deg. to 32 deg. indicating enhancement in hydrophilicity. This mainly attributes to surface roughening, which is due to the electron beam induced sputtering. The surface roughening is confirmed in AFM and profilometry measurements. The AFM images clearly show that surface roughness increases after electron irradiation. Moreover, the roughness average (R{sub a}) as measured from surface profilograms is found to increase from 0.06 to 0.1. The FTIR and UV-vis spectra do not show noticeable changes as regards to scissioning of bonds and the oxidation. This work leads to a definite conclusion that 6 MeV pulsed electron beam can be used to bring about desired changes in surface as well as bulk properties of polyimide, which is considered to be a high performance space quality polymer.

  5. Effects of high energy (MeV) ion beam irradiation on polyethylene terephthalate

    International Nuclear Information System (INIS)

    Singh, Nandlal; Sharma, Anita; Avasthi, D.K.

    2003-01-01

    Irradiation effects of 50 MeV Li 3+ ion beams in polyethylene terephthalate (PET) films were studied with respect to their structural and electrical properties by using Fourier transform infrared (FTIR) spectroscopy and ac electrical measurement in the frequency range: 50-100 kHz at different temperatures of 30-150 deg. C. It is found that ac resistivity of PET decreases as frequency increases. The temperature dependencies of dielectric loss tangent exhibit a peak (T g ) at 60 deg. C. The capacitance value of irradiated PET is almost temperature independent and ones increases with an increasing of lithium fluence. FTIR spectra show various bands related to C-H, C-O, C-O-C molecular bonds and groups which get modified or break down due to ion beam irradiation

  6. A 62-MeV Proton Beam for the Treatment of Ocular Melanoma at Laboratori Nazionali del Sud-INFN

    Science.gov (United States)

    Cirrone, G. A. P.; Cuttone, G.; Lojacono, P. A.; Lo Nigro, S.; Mongelli, V.; Patti, I. V.; Privitera, G.; Raffaele, L.; Rifuggiato, D.; Sabini, M. G.; Salamone, V.; Spatola, C.; Valastro, L. M.

    2004-06-01

    At the Istituto Nazionale di Fisica Nucleare-Laboratori Nazionali del Sud (INFN-LNS) in Catania, Italy, the first Italian protontherapy facility, named Centro di AdroTerapia e Applicazioni Nucleari Avanzate (CATANA) has been built in collaboration with the University of Catania. It is based on the use of the 62-MeV proton beam delivered by the K=800 Superconducting Cyclotron installed and working at INFN-LNS since 1995. The facility is mainly devoted to the treatment of ocular diseases like uveal melanoma. A beam treatment line in air has been assembled together with a dedicated positioning patient system. The facility has been in operation since the beginning of 2002 and 66 patients have been successfully treated up to now. The main features of CATANA together with the clinical and dosimetric features will be extensively described; particularly, the proton beam line, that has been entirely built at LNS, with all its elements, the experimental transversal and depth dose distributions of the 62-MeV proton beam obtained for a final collimator of 25-mm diameter and the experimental depth dose distributions of a modulated proton beam obtained for the same final collimator. Finally, the clinical results over 1 yr of treatments, describing the features of the treated diseases will be reported.

  7. Ion-source dependence of the distributions of internuclear separations in 2-MeV HeH+ beams

    International Nuclear Information System (INIS)

    Kanter, E.P.; Gemmell, D.S.; Plesser, I.; Vager, Z.

    1981-01-01

    Experiments involving the use of MeV molecular-ion beams have yielded new information on atomic collisions in solids. A central part of the analyses of such experiments is a knowledge of the distribution of internuclear separations contained in the incident beam. In an attempt to determine how these distributions depend on ion-source gas conditions, we have studied foil-induced dissociations of H 2+ , H 3+ , HeH + , and OH 2+ ions. Although changes of ion-source gas compositions and pressure were found to have no measurable influence on the vibrational state populations of the beams reaching our target, for HeH + we found that beams produced in our rf source were vibrationally hotter than beams produced in a duoplasmatron. This was also seen in studies of neutral fragments and transmitted molecules

  8. Dose measurements in the treatment of mycosis fungoides with total skin irradiation using a 4 MeV electron beam

    Energy Technology Data Exchange (ETDEWEB)

    Poli, M.E.R. [Hospital Real e Benemerita Sociedade Portuguesa de Beneficencia (Brazil); Todo, A.S.; Campos, L.L. [Instituto de Pesquisas Energeticas e Nucleares, CNEN/SP Travessa R, Sao Paulo (Brazil)

    2000-05-01

    The total skin irradiation (TSI) is one of the most efficient techniques in the treatment administered with curative intent of the mycosis fungoides. The cure may be obtained in 10% to 40% of cases. The original Stanford University technique, created in 1960, was applied in a 4.8 MeV linear accelerator, that provided 2.5 MeV electrons in the patient, by the use of 4 couple beams with the patient placed in front of the beam, 3 meters distant from the apparatus. In this work we describe a 4 MeV electrons beam treatment method. We intend to improve the uniformity of the dose in the patient, as well, to reduce the problems with the overlapping treatment fields, that occurs in conventional treatment that uses 1 meter of focus-skin distance, and the treatment time to the patient. Only one modification was done in the apparatus: the dose rate for this treatment was doubled. The patient is placed on a rotative base and he assumes successively 6 positions: stand up and perpendicular to the beam, distant 2.83 meters from the gantry, with 60 degrees of interval between the rotations. In each position, the patient receives a couple of beams (the beam angulation is 19.5 degrees above the transversal axis in the middle of the patient and 19.5 degrees below it). The dosimetric data obtained were compared to the international protocols (AAPM). The delivered doses in the patient were measured with thermoluminescent dosimeters placed on skin surface and with Kodak XV-2 films placed between different slabs of an anthropomorphic phantom. The dose distribution in the phantom shows a good uniformity, in all thickness of interest, so it is possible to use this technique in the treatment of the mycosis fungoides as well Kaposi's sarcoma. (author)

  9. 2 MeV/20 kW industrial electron beam accelerator vis-s-vis its vacuum system

    International Nuclear Information System (INIS)

    Khader, S.A.; Assadullah, M.; Sarma, K.S.S.; Bandi, L.N.

    2003-01-01

    Full text: Electron beam accelerators in the energy range 200 keV to 10 MeV have been extensively used for many radiation processing applications that include polymerization, polymer modifications, radiation sterilization, food irradiation and gem coloration. The accelerator technology is a multidisciplinary one wherein production of stable vacuum in various accelerator systems is of utmost importance to achieve required output beam parameters like beam energy and current for processing industrial products at large through puts on continuous basis. A 2 MeV, 20 kW industrial electron beam accelerator has been in operation since 2001 at BARC-BRIT complex, Navi Mumbai for commercial and R and D applications like crosslinking of wire and cables, heat shrinkable tubes, PE O rings, PTEE degradation and color enhancement in diamonds. The machine is a ILU-6 type pulse RF accelerator consisting of a single resonator copper cavity of 1.2 m diameter and 1.2 m height (volume:∼ 1.5 m3) placed inside a stainless steel container (called cavity container) and a s.s. beam extraction window wherein vacuum needs to be maintained at a minimum 10-6 torr. Four sputter ion pumps are directly fixed on the cavity container to obtain maximum pumping efficiency. The fore vacuum is generated using a combination rotary and a roots pump. The beam extraction widow has a 50 and 956 m thick titanium foil acting as the exit window for electrons from the vacuum into air. Both the cavity and the beam extraction window are coupled through a gate valve which acts as a vacuum separator isolating the systems from each other during foil puncture, scanning system failure or any other related problems. This paper reports details of the vacuum system, measurements, vacuum leaks and detection and the operational experience related to maintenance and troubleshooting exercises that have been carried in the accelerator

  10. Characterization of a power bipolar transistor as high-dose dosimeter for 1.9-2.2 MeV electron beams

    Energy Technology Data Exchange (ETDEWEB)

    Fuochi, P.G., E-mail: fuochi@isof.cnr.i [ISOF-CNR Institute, Via P. Gobetti 101, I-40129, Bologna (Italy); Lavalle, M.; Corda, U. [ISOF-CNR Institute, Via P. Gobetti 101, I-40129, Bologna (Italy); Kuntz, F.; Plumeri, S. [Aerial, Parc d' Innovation Rue Laurent Fries F-67400 Illkirch (France); Gombia, E. [IMEM-CNR Institute, Viale delle Scienze 37 A, Loc. Fontanini, 43010 Parma (Italy)

    2010-04-15

    Results of the characterization studies on a power bipolar transistor investigated as a possible radiation dosimeter under laboratory condition using electron beams of energies from 2.2 to 8.6 MeV and gamma rays from a {sup 60}Co source and tested in industrial irradiation plants having high-activity {sup 60}Co gamma-source and high-energy, high-power electron beam have previously been reported. The present paper describes recent studies performed on this type of bipolar transistor irradiated with 1.9 and 2.2 MeV electron beams in the dose range 5-50 kGy. Dose response, post-irradiation heat treatment and stability, effects of temperature during irradiation in the range from -104 to +22 deg. C, dependence on temperature during reading in the range 20-50 deg. C, and the difference in response of the transistors irradiated from the plastic side and the copper side are reported. DLTS measurements performed on the irradiated devices to identify the recombination centres introduced by radiation and their dependence on dose and energy of the electron beam are also reported.

  11. In situ MeV ion beam analysis of ceramic surfaces modified by 100-400 keV ion irradiation

    International Nuclear Information System (INIS)

    Weber, W.J.; Yu, N.; Sickafus, K.E.

    1995-05-01

    This paper describes use of the in situ ion beam analysis facility developed at Los Alamos National Laboratory for the study of irradiation effects in ceramic materials. In this facility, an analytical beamline of 3 MV tandem accelerator and an irradiation bean-dine of 200 kV ion implanter are connected at 60 degrees to a common target chamber. This facility provides a fast, efficient, and quantitative measurement tool to monitor changes of composition and crystallinity of materials irradiated by 100-400 keV ions, through sequential measurement of backscattering events of MeV ions combined with ion channeling techniques. We will describe the details of the in situ ion beam analysis and ion irradiation and discuss some of the important issues and their solutions associated with the in situ experiment. These issues include (1) the selection of axial ion channeling direction for the measurement of radiation damage; (2) surface charging and charge collection for data acquisition; (3) surface sputtering during ion irradiation; (4) the effects of MeV analytical beam on the materials; and (5) the sample heating effect on ion beam analysis

  12. The Fermilab 400-MeV Linac Upgrade

    International Nuclear Information System (INIS)

    Schmidt, C.W.

    1993-05-01

    The Fermilab Linac Upgrade will increase the linac energy from 201 MeV to 401.5 MeV. Seven accelerating modules, composed of 805-MHz side-coupled cells, will accelerate H - beams from 116.5 to 401.5 MeV. The side-coupled structure (SCS) has been built, tuned, tested to full power, and placed in the linac enclosure along side the operating Linac. All seven accelerating modules, each containing four sections of sixteen cells, have been connected to 12-MW power klystrons and tested to full power for a significant period. The transition section to match the beam from the 201.25-MHz drift-tube linac to the SCS, consisting of a sixteen-cell cavity and a vernier four-cell cavity, has also been tested at full power. A new import line from the Linac to the Booster synchrotron with a new Booster injection girder is to be installed. Removal of the last four Alvarez linac tanks (116.5 to 201 MeV) and beam-line installation of the Upgrade components is to begin in early June 1993 and should take about 12 weeks. Beam commissioning of the project will follow and normal operation is expected in a short period. In preparation for beam commissioning, studies are being done with done operating linac to characterize the beam at transition and prepare for phase, amplitude and energy measurements to commission the new linac. The past, present and future activities of the 400-MeV Upgrade will be reviewed

  13. Design for a 1.3 MW, 13 MeV Beam Dump for an Energy Recovery Linac

    CERN Document Server

    Sinclair, Charles K; Smith, Colin H

    2005-01-01

    The electron beam exiting an Energy Recovery Linac (ERL) is dumped close to the injection energy. This energy is chosen as low as possible while allowing the beam quality specifications to be met. As ERLs are designed for high average beam current, beam dumps are required to handle high beam power at low energy. Low energy electrons have a short range in practical dump materials, requiring the beam size at the dump face be enlarged to give acceptable power densities and heat fluxes. Cornell University is developing a 100 mA average current ERL as a synchrotron radiation source. The 13 MeV optimum injection energy requires a 1.3 MW beam dump. We present a mature design for this dump, using an array of water-cooled extruded copper tubes. This array is mounted in the accelerator vacuum normal to the beam. Fatigue failure resulting from abrupt thermal cycles associated with beam trips is a potential failure mechanism. We report on designs for a 75 kW, 750 keV tube-cooled beryllium plate dump for electron gun test...

  14. A beam optics study of the biomedical beam line at a proton therapy facility

    International Nuclear Information System (INIS)

    Yun, Chong Cheoul; Kim, Jong-Won

    2007-01-01

    A biomedical beam line has been designed for the experimental area of a proton therapy facility to deliver mm to sub-mm size beams in the energy range of 20-50 MeV using the TRANSPORT/TURTLE beam optics codes and a newly-written program. The proton therapy facility is equipped with a 230 MeV fixed-energy cyclotron and an energy selection system based on a degrader and slits, so that beam currents available for therapy decrease at lower energies in the therapeutic beam energy range of 70-230 MeV. The new beam line system is composed of an energy-degrader, two slits, and three quadrupole magnets. The minimum beam sizes achievable at the focal point are estimated for the two energies of 50 and 20 MeV. The focused FWHM beam size is approximately 0.3 mm with an expected beam current of 20 pA when the beam energy is reduced to 50 MeV from 100 MeV, and roughly 0.8 mm with a current of 10 pA for a 20 MeV beam

  15. Measurement of the distributions of internuclear separations in 3.0-MeV H2+ and 3.63-MeV HeH+ beams

    International Nuclear Information System (INIS)

    Kanter, E.P.; Cooney, P.J.; Gemmell, D.S.; Vager, Z.; Pietsch, W.J.; Zabransky, B.J.

    1979-01-01

    Angular distributions of charged dissociation fragments are measured for 3.0-MeV H 2 + and 3.63-MeV HeH + ions incident on approx. 160 A carbon targets. By using the reflection method for a pure Coulomb potential, there are unfolded from these data the distributions of internuclear separations for each molecular-ion species prior to dissociation. These results are insensitive to ion-source conditions. For H 2 + this distribution, while approx. 2 times wider than a pure ground vibrational state population, is markedly different from the Franck-Condon distribution that has been previously assumed by other authors with similar rf and duo-plasmatron ion sources. For HeH + the distribution is slightly broader (approx. 1.5 times) than that expected for a pure ground state population. From the data, the initial vibrational state population in the incident beam can be extracted. 11 references

  16. High power 1 MeV neutral beam system and its application plan for the international tokamak experimental reactor

    Energy Technology Data Exchange (ETDEWEB)

    Hemsworth, R S [ITER Joint Central Team, Naka, Ibaraki (Japan)

    1997-03-01

    This paper describes the Neutral Beam Injection system which is presently being designed for the International Tokamak Experimental Reactor, ITER, in Europe Japan and Russia, with co-ordination by the Joint Central Team of ITER at Naka, Japan. The proposed system consists of three negative ion based neutral injectors, delivering a total of 50 MW of 1 MeV D{sup 0} to the ITER plasma for a pulse length of >1000 s. Each injectors uses a single caesiated volume arc discharge negative ion source, and a multi-grid, multi-aperture accelerator, to produce about 40 A of 1 MeV D{sup -}. This will be neutralized by collisions with D{sub 2} in a sub-divided gas neutralizer, which has a conversion efficiency of about 60%. The charged fraction of the beam emerging from the neutralizer is dumped in an electrostatic residual ion dump. A water cooled calorimeter can be moved into the beam path to intercept the neutral beam, allowing commissioning of the injector independent of ITER. ITER is scheduled to produce its first plasma at the beginning of 2008, and the planning of the R and D, construction and installation foresees the neutral injection system being available from the start of ITER operations. (author)

  17. Microbial decontaminations of species by 10 MeV E- Beam

    International Nuclear Information System (INIS)

    Mehdizadeh Shahi, A.; Fallahnejad, N.

    2005-01-01

    Spices are used significantly in food industries. These substances contain high microbial contamination that causes the spoilage of the products and it is also hazardous for the health of consumers. Irradiation is one of the most effective methods to decontaminate spices. In this research , the optimum dose of e-beams to reduce microbial contamination of spices is determined. Samples of spices such as: turmeric, black pepper, garlic powder, onion powder, oregano and spice, were packaged in 10 grams, and they were irradiated at the dose of 0-10 kGy by 10 MeV e-beams. After irradiation, the total microbial counts were determined by the pour plating method. The bacterial contamination of different spices was between 10 5 to 4.7 x 10 7 cfu/gr and the molds count was between 1.8x10 2 to 7.2 x 10 3 cfu/gr. The survival curve of the bacteria was drawn in terms of bio burden versus the radiation dose rates. By determining the D 10 value, the minimum dose for reducing the spices microbial contamination up to the optimum limit, were identified

  18. Imaging nanoscale spatial modulation of a relativistic electron beam with a MeV ultrafast electron microscope

    Science.gov (United States)

    Lu, Chao; Jiang, Tao; Liu, Shengguang; Wang, Rui; Zhao, Lingrong; Zhu, Pengfei; Liu, Yaqi; Xu, Jun; Yu, Dapeng; Wan, Weishi; Zhu, Yimei; Xiang, Dao; Zhang, Jie

    2018-03-01

    An accelerator-based MeV ultrafast electron microscope (MUEM) has been proposed as a promising tool to the study structural dynamics at the nanometer spatial scale and the picosecond temporal scale. Here, we report experimental tests of a prototype MUEM where high quality images with nanoscale fine structures were recorded with a pulsed ˜3 MeV picosecond electron beam. The temporal and spatial resolutions of the MUEM operating in the single-shot mode are about 4 ps (FWHM) and 100 nm (FWHM), corresponding to a temporal-spatial resolution of 4 × 10-19 s m, about 2 orders of magnitude higher than that achieved with state-of-the-art single-shot keV UEM. Using this instrument, we offer the demonstration of visualizing the nanoscale periodic spatial modulation of an electron beam, which may be converted into longitudinal density modulation through emittance exchange to enable production of high-power coherent radiation at short wavelengths. Our results mark a great step towards single-shot nanometer-resolution MUEMs and compact intense x-ray sources that may have widespread applications in many areas of science.

  19. New source of MeV negative ion and neutral atom beams

    International Nuclear Information System (INIS)

    Ter-Avetisyan, S.; Braenzel, J.; Schnürer, M.; Prasad, R.; Borghesi, M.; Jequier, S.; Tikhonchuk, V.

    2016-01-01

    The scenario of “electron-capture and -loss” was recently proposed for the formation of negative ion and neutral atom beams with MeV kinetic energies. However, it does not explain why the formation of negative ions in a liquid spray is much more efficient than with an isolated atom. The role of atomic excited states in the charge-exchange processes is considered, and it is shown that it cannot account for the observed phenomena. The processes are more complex than the single electron-capture and -loss approach. It is suggested that the shell effects in the electronic structure of the projectile ion and/or target atoms may influence the capture/loss probabilities

  20. New source of MeV negative ion and neutral atom beams

    Energy Technology Data Exchange (ETDEWEB)

    Ter-Avetisyan, S., E-mail: sargis@gist.ac.kr [Center for Relativistic Laser Science, Institute for Basic Science (IBS), Gwangju 500-712 (Korea, Republic of); Department of Physics and Photon Science, GIST, Gwangju 500-712 (Korea, Republic of); Braenzel, J.; Schnürer, M. [Max Born Institute for Nonlinear Optics and Short Pulse Spectroscopy, Berlin 12489 (Germany); Prasad, R. [Institute for Laser and Plasma Physics, Heinrich Heine University, Duesseldorf 40225 (Germany); Borghesi, M. [School of Mathematics and Physics, The Queen’s University of Belfast, Belfast BT7-1NN (United Kingdom); Jequier, S.; Tikhonchuk, V. [Centre Lasers Intenses et Applications, CEA, CNRS, University of Bordeaux, 33405 Talence (France)

    2016-02-15

    The scenario of “electron-capture and -loss” was recently proposed for the formation of negative ion and neutral atom beams with MeV kinetic energies. However, it does not explain why the formation of negative ions in a liquid spray is much more efficient than with an isolated atom. The role of atomic excited states in the charge-exchange processes is considered, and it is shown that it cannot account for the observed phenomena. The processes are more complex than the single electron-capture and -loss approach. It is suggested that the shell effects in the electronic structure of the projectile ion and/or target atoms may influence the capture/loss probabilities.

  1. A high intensity beam line of γ-rays up to 22MeV energy based on Compton backscattering

    International Nuclear Information System (INIS)

    Guo, W.; Xu, W.; Chen, J.G.; Ma, Y.G.; Cai, X.Z.; Wang, H.W.; Xu, Y.; Wang, C.B.; Lu, G.C.; Tian, W.D.; Yuan, R.Y.; Xu, J.Q.; Wei, Z.Y.; Yan, Z.; Shen, W.Q.

    2007-01-01

    Shanghai Laser Electron Gamma Source, a high intensity beam line of γ-ray, has been proposed recently. The beam line is expected to generate γ-rays up to the maximum energy of 22MeV by Compton backscattering between a CO 2 laser and electrons in the 3.5 GeV storage ring of the Shanghai Synchrotron Radiation Facility. The flux of non-collimated γ-rays is estimated to be 10 9 -10 10 s -1 when a CO 2 laser of several hundred Watt power is employed. We will discuss physics issues in the design and optimization of the beam line

  2. Efficient production and diagnostics of MeV proton beams from a cryogenic hydrogen ribbon

    International Nuclear Information System (INIS)

    Velyhan, A.; Giuffrida, L.; Scuderi, V.; Lastovicka, T.; Margarone, D.; Perin, J.P.; Chatain, D.; Garcia, S.; Bonnay, P.; Dostal, J.; Ullschmied, J.; Dudzak, R.; Krousky, E.; Cykhardt, J.; Prokupek, J.; Pfeifer, M.; Rosinski, M.; Krasa, J.; Brabcova, K.; Napoli, M. De

    2017-01-01

    A solid hydrogen thin ribbon, produced by the cryogenic system ELISE (Experiments on Laser Interaction with Solid hydrogEn) target delivery system, was experimentally used at the PALS kJ-laser facility to generate intense proton beams with energies in the MeV range. This sophisticated target system operating at cryogenic temperature (∼ 10 K) continuously producing a 62 μm thick target was combined with a 600 J sub-nanosecond laser pulse to generate a collimated proton stream. The accelerated proton beams were fully characterized by a number of diagnostics. High conversion efficiency of laser to energetic protons is of great interest for future potential applications in non-conventional proton therapy and fast ignition for inertial confinement fusion.

  3. Fabrication of a negative PMMA master mold for soft-lithography by MeV ion beam lithography

    Science.gov (United States)

    Puttaraksa, Nitipon; Unai, Somrit; Rhodes, Michael W.; Singkarat, Kanda; Whitlow, Harry J.; Singkarat, Somsorn

    2012-02-01

    In this study, poly(methyl methacrylate) (PMMA) was investigated as a negative resist by irradiation with a high-fluence 2 MeV proton beam. The beam from a 1.7 MV Tandetron accelerator at the Plasma and Beam Physics Research Facility (PBP) of Chiang Mai University is shaped by a pair of computer-controlled L-shaped apertures which are used to expose rectangular pattern elements with 1-1000 μm side length. Repeated exposure of rectangular pattern elements allows a complex pattern to be built up. After subsequent development, the negative PMMA microstructure was used as a master mold for casting poly(dimethylsiloxane) (PDMS) following a standard soft-lithography process. The PDMS chip fabricated by this technique was demonstrated to be a microfluidic device.

  4. Fabrication of a negative PMMA master mold for soft-lithography by MeV ion beam lithography

    International Nuclear Information System (INIS)

    Puttaraksa, Nitipon; Unai, Somrit; Rhodes, Michael W.; Singkarat, Kanda; Whitlow, Harry J.; Singkarat, Somsorn

    2012-01-01

    In this study, poly(methyl methacrylate) (PMMA) was investigated as a negative resist by irradiation with a high-fluence 2 MeV proton beam. The beam from a 1.7 MV Tandetron accelerator at the Plasma and Beam Physics Research Facility (PBP) of Chiang Mai University is shaped by a pair of computer-controlled L-shaped apertures which are used to expose rectangular pattern elements with 1–1000 μm side length. Repeated exposure of rectangular pattern elements allows a complex pattern to be built up. After subsequent development, the negative PMMA microstructure was used as a master mold for casting poly(dimethylsiloxane) (PDMS) following a standard soft-lithography process. The PDMS chip fabricated by this technique was demonstrated to be a microfluidic device.

  5. Basic Research and Feasibility Study of Radioisotope Production using 100 MeV Proton Beam

    International Nuclear Information System (INIS)

    Yoo, K. H.; Yoon, K. S.; Cho, W. J.; Park, S. I.; Han, H. S.; Yang, S. D.; Jeon, K. S.; Kim, J. H.; Yang, T. K.

    2010-04-01

    Results of the project are various nuclei, such as 82 Rb, 68 Ga, 67 Cu, 22 Na and so on, can be produced by irradiating 100 MeV proton beam, by irradiating proton beam to the nat Ga target, the 68 Ge, mother nucleus of positron emitting 68 Ga, is produced based on the nat Ga(p,x) 68 Ge reaction, the target system for the high-energy of proton beam can produce more than 2 species of radioisotope at the same time by employing tandem targets, 68 Ge/ 68 Ga generator, 82 Sr(25.34d)/ 82 Rb generator - 67 Cu production method, 70 Zn electroplating technology based on the electrochemistry, the container, whose weight is about 3 ton, is made by depleted uranium and because of the unstable situation for the supply and demand of reactor produced radioisotope, the need for the cyclotron produced radioisotopes is dramatically increased all over the world.

  6. Characterization of 2 MeV, 4 MeV, 6 MeV and 18 MeV buildup caps for use with a 0.6 cubic centimeter thimble ionization chamber

    International Nuclear Information System (INIS)

    Salyer, R.L.; VanDenburg, J.W.; Prinja, A.K.; Kirby, T.; Busch, R.; Hong-Nian Jow

    1996-07-01

    The purpose of this research is to characterize existing 2 MeV, 4 MeV and 6 MeV buildup caps, and to determine if a buildup cap can be made for the 0.6 cm 3 thimble ionization chamber that will accurately measure exposures in a high-energy photon radiation field. Two different radiation transport codes were used to computationally characterize existing 2 MeV, 4 MeV, and 6 MeV buildup caps for a 0.6 cm 3 active volume thimble ionization chamber: ITS, The Integrated TIGER Series of Coupled Electron-Photon Monte Carlo Transport Codes; and CEPXS/ONEDANT, A One-Dimensional Coupled Electron-Photon Discrete Ordinates Code Package. These codes were also used to determine the design characteristics of a buildup cap for use in the 18 MeV photon beam produced by the 14 TW pulsed power HERMES-III electron accelerator. The maximum range of the secondary electron, the depth at which maximum dose occurs, and the point where dose and collision kerma are equal have been determined to establish the validity of electronic equilibrium. The ionization chamber with the appropriate buildup cap was then subjected to a 4 MeV and a 6 MeV bremmstrahlung radiation spectrum to determine the detector response

  7. Bunch-shape monitor for a picosecond single-bunch beam of a 35 MeV electron linear accelerator

    International Nuclear Information System (INIS)

    Hosono, Yoneichi; Nakazawa, Masaharu; Iguchi, Tetsuo

    1995-01-01

    A non-interactive-type bunch-shape and beam intensity monitor for a 35 MeV electron linear accelerator (linac) has been developed. The monitor consists of an electric SMA-type connector and an Al pipe of 50 mm inner diameter. Test measurements of the present monitor have been made under the conditions of the accelerated charges of lower than 27 nC/pulse and the pulse width ranging from 6 to 30 ps (Full Width at Half Maximum). The results show that the present monitor is applicable to bunch-shape measurement of the picosecond single-bunch beam. The monitor output is also found to be proportional to the beam intensity of more than 0.05 nC/pulse. (author)

  8. Beam-beam effect and luminosity in SPEAR

    International Nuclear Information System (INIS)

    Wiedemann, H.

    1980-01-01

    Many measurements on the beam-beam limit in SPEAR have been performed over the past years. The goal for these measurements was to find the proper parameterization of the beam-beam effect. All measurements presented were done with both beams equally blown up by control of the flip-flop phenomenon. Colliding beam measurements were made at energies as low as 600 MeV and together with earlier measurements the author presents the scaling of some relevant storage ring parameters from 600 MeV up to almost 4 GeV. (Auth.)

  9. Microbeam line of MeV heavy ions for materials modification and in-situ analysis

    International Nuclear Information System (INIS)

    Horino, Yuji; Chayahara, Akiyoshi; Kiuchi, Masato; Fujii, Kanenaga; Satoh, Mamoru; Takai, Mikio.

    1990-01-01

    A microbeam line for MeV heavy ions of almost any element has been developed for microion-beam processing such as maskless MeV ion implantation and its in-situ analysis. Beam spot sizes of 4.0 μm x 4.0 μm for 3 MeV C 2+ and 9.6 μm x 4.8 μm for 1.8 MeV Au 2+ beams were obtained. Maskless MeV gold ion implantation to a silicon substrate and in-situ microanalysis before and after ion implantation were demonstrated. (author)

  10. Synchronous phase and energy measurement system for a 6.7-MeV H- beam

    International Nuclear Information System (INIS)

    Gilpatrick, J.D.; Meyer, R.E.; Wells, F.D.; Power, J.F.; Shafer, R.E.

    1988-01-01

    A noninterceptive measurement system has been built to measure the energy and synchronous phase of a 6.7-MeV proton beam drifting from the ramped-gradient, drift-tube linac (RGDTL) in the accelerator test stand (ATS) facility. Axially-symmetric, capacitive probes used in these measurements produce signals that are proportional to the beam image current on their inner rings. Signals from two of these probes separated by 92.6 cm are down-converted from 425 to 20 MHz. The phase difference between these 20-MHz signals is then detected with an electronic, phase-comparator circuit. The phase-comparator signal output is a voltage that is related to momentum of the beam. A phase comparison is also provided between the 425-MHz fundamental rf field inside the RGDTL and the capacitive probe located nearest the RGDTL output. The total estimated error for the absolute and relative energy measurement is less than +- 12.2 and +- 3.1 keV, respectively. The total estimated error for the relative synchronous phase measurement is less than +-1/degree/. Beam energy versus synchronous phase experimental data agree with computer simulations. 3 refs., 3 figs., 1 tab

  11. First measurement of the polarisation asymmetry of a gamma-ray beam between 1.7 to 74 MeV with the HARPO TPC

    Science.gov (United States)

    Gros, P.; Amano, S.; Attié, D.; Bernard, D.; Bruel, P.; Calvet, D.; Colas, P.; Daté, S.; Delbart, A.; Frotin, M.; Geerebaert, Y.; Giebels, B.; Götz, D.; Hashimoto, S.; Horan, D.; Kotaka, T.; Louzir, Marc; Minamiyama, Y.; Miyamoto, S.; Ohkuma, H.; Poilleux, Patrick; Semeniouk, I.; Sizun, P.; Takemoto, A.; Yamaguchi, M.; Wang, S.

    2016-07-01

    Current γ-ray telescopes suffer from a gap in sensitivity in the energy range between 100 keV and 100 MeV, and no polarisation measurement has ever been done on cosmic sources above 1 MeV. Past and present e+e- pair telescopes are limited at lower energies by the multiple scattering of electrons in passive tungsten converter plates. This results in low angular resolution, and, consequently, a drop in sensitivity to point sources below 1 GeV. The polarisation information, which is carried by the azimuthal angle of the conversion plane, is lost for the same reasons. HARPO is an R&D program to characterise the operation of a gaseous detector (a Time Projection Chamber or TPC) as a high angular-resolution and sensitivity telescope and polarimeter for γ-rays from cosmic sources. It represents a first step towards a future space instrument in the MeV-GeV range. We built and characterised a 30cm cubic demonstrator [SPIE 91441M], and put it in a polarised γ-ray beam at the NewSUBARU accelerator in Japan. Data were taken at photon energies from 1.74MeV to 74MeV and with different polarisation configurations. We describe the experimental setup in beam. We then describe the software we developed to reconstruct the photon conversion events, with special focus on low energies. We also describe the thorough simulation of the detector used to compare results. Finally we will present the performance of the detector as extracted from this analysis and preliminary measurements of the polarisation asymmetry. This beam-test qualification of a gas TPC prototype in a γ-ray beam could open the way to high-performance -ray astronomy and polarimetry in the MeV-GeV energy range in the near future.

  12. Klystron High Power Operation for KOMAC 100-MeV Proton Linac

    Energy Technology Data Exchange (ETDEWEB)

    Seol, Kyung-Tae; Kim, Seong-Gu; Kwon, Hyeok-Jung; Kim, Han-Sung; Cho, Yong-Sub [KAERI, Daejeon (Korea, Republic of)

    2015-05-15

    The Korea multi-purpose accelerator complex (KOMAC) accelerator facility has a 100-MeV proton linac, five beam lines for 20-MeV beam utilization, and another five beam lines for 100-MeV beam utilization. The 100-MeV linac consists of a 50-keV proton injector based on a microwave ion source, a 3-MeV RFQ with a four-vane structure, and a 100-MeV DTL. Nine sets of 1MW klystrons have been operated for the 100-MeV proton linac. The klystron filament heating time was approximately 5700 hours in 2014, and RF operation time was 2863.4 hours. During the high power operation of the klystron, unstable RF waveforms appeared at the klystron output, and we have checked and performed cavity frequency adjustments, magnet and heater current, reflection from a circulator, klystron test without a circulator, and the frequency spectrum measurement. Nine sets of the klystrons have been operated for the KOMAC 100-MeV proton linac. The klystron filament heating time was 5700 hours and RF operation time was 2863.4 hours during the operation in 2014. Some klystrons have unstable RF waveforms at specific power level. We have checked and tested the cavity frequency adjustment, reflection from a circulator, high power test without a circulator, and frequency spectrum at the unstable RF.

  13. The electron beam characteristics of energies up to 20 MeV and comparison of electron parameters of linear accelerators

    International Nuclear Information System (INIS)

    Awada, M.; Elleithy, M.A.; ElWihady, G.F.; Mostafa, K.A.

    2005-01-01

    The electron beams characteristics studded for the energies 4-20 MeV of Varian 23 EX ,experimental results are presented and compared with the published data. The CADD curves are measured for all energies and carried out the PDD of different applicator sizes ,that compared with the PDD of in the BJR. The quality beam parameters are determined from the CADD curves and calculated the yielded parameters of the corresponding electron energies which compared with the published data of other accelerators and theoretical Monte-Carlo calculation. The beam profiles are measured at different depths to construct the isodose distribution

  14. Physics design of a 70 MeV high intensity cyclotron, CYCIAE-70

    International Nuclear Information System (INIS)

    Zhang Tianjue; An Shizhong; Wang Chuan; Yin Zhiguo; Wei Sumin; Li Ming; Yang Jianjun; Ji Bin; Jia Xianlu; Zhong Junqing; Yang Fang

    2011-01-01

    This paper introduces the physics design of a 70 MeV high intensity cyclotron at China Institute of Atomic Energy (CIAE), which is aimed for multiple uses including radioactive ion-beam (RIB) production. The machine adopts a compact structure of four straight sectors, capable of accelerating two kinds of beams, i.e. H − and D − . The proton and deuteron beam will be extracted in dual opposite directions by charge exchange stripping devices. The energy of the extracted proton beam is in the range 35–70 MeV with an intensity up to 700 μA. The corresponding values for the deuteron beam are 18–33 MeV and 40 μA. This paper will present the main characteristics and parameters in the design of the 70 MeV cyclotron, the results of the basic beam dynamics study, as well as the physics in the design of the different systems, including the main magnet, RF, injection and extraction systems, etc.

  15. The 600 MeV Saclay electron linac: 40000 hour operation

    International Nuclear Information System (INIS)

    Netter, F.

    1977-01-01

    After 40000 hours of operation, the 600 MeV Saclay's electron linac (ALS) does appear as an efficient and versatile tool, for high resolution work (20 μA in ΔE = 40 keV at E = 200MeV), for high power pion production (300 μA in 20 μs pulses at 1000 Hz and 400 MeV or 240 μA in 4 μs pulses at 3000 Hz and 390 MeV), for highly reliable positron beams acceleration, a.s.o. Main improvements made in the recent years are described in particular the automatic beam switching between any two ways among the beam handling system; and the computer newly installed in the control room with a powerful visual display allowing an easy and flexible dialogue of the operators with the computer [fr

  16. Beam dynamics and commissioning of low and medium energy H- beam at Linac4

    CERN Document Server

    Satri, Masoomeh Yarmohammadi; Lombardi, Alessandra; Lamehi-Rachti , Mohammad

    The First step of the CERN Large Hadron Collider injectors upgrade (LIU) project is Linac4. It accelerates H- ions to 160 MeV in an 80 m long accelerator housed in a tunnel 12 m underground, presently under construction. It will replace the present 50 MeV proton Linac2 as injector of the proton accelerator complex to increase the LHC luminosity. It consists of a 45 keV RF volume source, a twosolenoid Low Energy Beam Transport (LEBT), a 352.2 MHz Radio Frequency Quadrupole (RFQ) accelerating the beam to 3 MeV, a Medium Energy Beam Transport (MEBT) line. The MEBT houses a fast chopper to selectively remove unwanted micro-bunches in the 352 MHz sequence and avoid losses at capture in the CERN PSB (1 MHz). After chopping, the beam acceleration continues by a 50 MeV Drift Tube Linac (DTL), a 100 MeV Cell-Coupled Drift Tube Linac and a Pi-Mode Structure bringing the beam to the final energy of 160 MeV. Linac4 has been commissioned with a temporary source up to 12 MeV. The beam commissioning stages of Linac4 in LEBT...

  17. Simultaneous quantification of Li, Ti and O in Lithium titanate by particle induced gamma-ray emission using 8 MeV proton beam

    International Nuclear Information System (INIS)

    Chhillar, Sumit; Acharya, R.; Tripathi, R.; Sodaye, S.; Sudarshan, K.; Pujari, P.K.; Rout, P.C.; Mukherjee, S.K.

    2014-01-01

    Simultaneous quantification of Li, Ti and O in lithium titanate (Li 2 TiO 3 ) is difficult by particle induced gamma-ray emission (PIGE) using low energy (∼4 MeV) proton beam. PIGE method using 8 MeV proton beam at BARC-TIFR pelletron facility was standardized for compositional characterization of sol-gel synthesized Li 2 TiO 3 by determining concentrations of Li, Ti and O simultaneously. Thick targets of samples, synthetic samples and standards were prepared in graphite matrix. Beam current variation was normalized by Rutherford Backscattering Spectrometry (RBS) using a thin gold foil. The gamma-rays of 478, 981 and 6129 keV were measured from 7 Li(p, p'γ) 7 Li, 48 Ti(p, p'γ) 48 Ti and 16 O(p, p'γ) 16 O nuclear reactions for quantification of Li, Ti and O, respectively. The method was validated by determining concentrations of Li, TI and O in a synthetic sample. (author)

  18. The JHP 200-MeV proton linear accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Kato, Takao [National Lab. for High Energy Physics, Tsukuba, Ibaraki (Japan)

    1997-11-01

    A 200-MeV proton linear accelerator for the Japanese Hadron Project (JHP) has been designed. It consists of a 3-MeV radio-frequency quadrupole linac (RFQ), a 50-MeV drift tube linac (DTL) and a 200-MeV separated-type drift tube linac (SDTL). A frequency of 324 MHz has been chosen for all of the rf structures. A peak current of 30 mA (H{sup -} ions) of 400 {mu}sec pulse duration will be accelerated at a repetition rate of 25 Hz. A future upgrade plan up to 400 MeV is also presented, in which annular-coupled structures (ACS) of 972 MHz are used in an energy range of above 150 or 200 MeV. One of the design features is its high performance for a beam-loss problem during acceleration. It can be achieved by separating the transition point in the transverse motion from that of the longitudinal motion. The transverse transition at a rather low-energy range decreases the effects of space-charge, while the longitudinal transition at a rather high-energy range decreases the effects of nonlinear problems related to acceleration in the ACS. Coupled envelope equations and equipartitioning theory are used for the focusing design. The adoption of the SDTL structure improves both the effective shunt impedance and difficulties in fabricating drift tubes with focusing magnets. An accurate beam-simulation code on a parallel supercomputer was used for confirming any beam-loss problem during acceleration. (author)

  19. High-resolution Auger spectroscopy on 79 MeV Ar5+, 89 MeV Ar6+, and 136 MeV Ar7+ ions after excitation by helium

    International Nuclear Information System (INIS)

    Schneider, T.

    1988-01-01

    In this thesis the atomic structure of highly excited Ar 6+ and Ar 7+ ions was studied. For this 79 MeV Ar 5+ , 89 MeV Ar 6+ , and 136 MeV Ar 7+ ions of a heavy ion accelerator were excited by a He gas target to autoionizing states and the Auger electrons emitted in the decay were measured in highly-resolving state. The spectra were taken under an observational angle of zero degree relative to the beam axis in order to minimize the kinematical broadening of the Auger lines. (orig./HSI) [de

  20. Electromagnetic design and beam dynamics studies for a 10 MeV, 10 kW electron linac

    International Nuclear Information System (INIS)

    Dhingra, Rinky; Kulkarni, Nita S.; Kumar, Vinit

    2013-01-01

    Bi-periodic on-axis coupled standing wave linac is seen as an attractive choice for low energy (∼10 MeV) electron accelerators for industrial applications. In this paper, we present the physics design of an S-band bi-periodic on-axis coupled standing wave structure operating in π/2 mode. The structure operates at 2856 MHz and can accelerate electrons to 10 MeV. The 2D optimization of structure cells carried out using SUPERFISH is reported. Magnetic coupling is achieved through bean shaped coupling slots. Analytical calculations have been carried out to fix the dimensions of coupling slots. The paper discusses the complete 3D design of accelerating structure with coupling slots carried out using CST-MWS. The approach used to achieve confluence is outlined. Finally, the beam dynamics studies carried out using PARMELA are also discussed. (author)

  1. Ion Beam Materials Analysis and Modifications at keV to MeV Energies at the University of North Texas

    Science.gov (United States)

    Rout, Bibhudutta; Dhoubhadel, Mangal S.; Poudel, Prakash R.; Kummari, Venkata C.; Lakshantha, Wickramaarachchige J.; Manuel, Jack E.; Bohara, Gyanendra; Szilasi, Szabolcs Z.; Glass, Gary A.; McDaniel, Floyd D.

    2014-02-01

    The University of North Texas (UNT) Ion Beam Modification and Analysis Laboratory (IBMAL) has four particle accelerators including a National Electrostatics Corporation (NEC) 9SDH-2 3 MV tandem Pelletron, a NEC 9SH 3 MV single-ended Pelletron, and a 200 kV Cockcroft-Walton. A fourth HVEC AK 2.5 MV Van de Graaff accelerator is presently being refurbished as an educational training facility. These accelerators can produce and accelerate almost any ion in the periodic table at energies from a few keV to tens of MeV. They are used to modify materials by ion implantation and to analyze materials by numerous atomic and nuclear physics techniques. The NEC 9SH accelerator was recently installed in the IBMAL and subsequently upgraded with the addition of a capacitive-liner and terminal potential stabilization system to reduce ion energy spread and therefore improve spatial resolution of the probing ion beam to hundreds of nanometers. Research involves materials modification and synthesis by ion implantation for photonic, electronic, and magnetic applications, micro-fabrication by high energy (MeV) ion beam lithography, microanalysis of biomedical and semiconductor materials, development of highenergy ion nanoprobe focusing systems, and educational and outreach activities. An overview of the IBMAL facilities and some of the current research projects are discussed.

  2. Thick-target neutron, gamma-ray, and radionuclide production for protons below 12 MeV on nickel and carbon beam-stops

    International Nuclear Information System (INIS)

    Chadwick, M.B.; Young, P.G.; Wilson, W.B.

    1998-03-01

    Nuclear model calculations using the GNASH code are described for protons below 12 MeV incident on nickel and carbon isotopes, for beam stop design in the Los Alamos Accelerator Production of Tritium Low Energy Demonstration Accelerator (LEDA) project. The GNASH calculations apply Hauser-Feshbach and preequilibrium reaction theories and can make use of pre-calculated direct reaction cross sections to low-lying residual nucleus states. From calculated thin target cross sections, thick target 6.7 MeV and 12 MeV proton-induced production of neutrons, gamma rays, and radionuclides are determined. Emission spectra of the secondary neutrons and gamma rays are also determined. The model calculations are validated through comparisons with experimental thin- and thick-target measurements. The results of this work are being utilized as source terms in MCNP analyses for LEDA

  3. A 30 MeV H- cyclotron for isotope production

    International Nuclear Information System (INIS)

    Baartman, R.; Kleevan, W.J.; Laxdal, R.E.; Milton, B.F.; Otter, A.J.; Pearson, J.B.; Poirier, R.L.; Schmor, P.W.; Schneider, H.R.; Erdman, K.L.; Walker, Q.

    1989-01-01

    Because of an expanding market for radioisotopes there is a need for a new generation of cyclotrons designed specifically for this purpose. We describe such a cyclotron currently under construction. It is a 30 MeV H - design that exploits a newly developed high brightness multicusp ion source which is capable of H - currents of up to 5 mA. This together with careful beam matching then makes feasible accelerated H - beam intensities of 500 μA. The cyclotron being built is a four sector radial ridge design with two 45 degree dees in opposite valleys. Beam extraction is by stripping to H + in a thin graphite foil. Two extraction probes will allow simultaneous extraction of two beams, each with an intensity of up to 200 μA. Energy variation from 15 MeV to 30 MeV is achieved by varying the radial position of the extraction foil. 7 refs., 4 figs., 1 tab

  4. Beam plasma 14 MeV neutron source for fusion materials development

    International Nuclear Information System (INIS)

    Ravenscroft, D.; Bulmer, D.; Coensgen, F.; Doggett, J.; Molvik, A.; Souza, P.; Summers, L.; Williamson, V.

    1991-09-01

    The conceptual engineering design and expected performance for a 14 MeV DT neutron source is detailed. The source would provide an intense neutron flux for accelerated testing of fusion reactor materials. The 150-keV neutral beams inject energetic deuterium atoms, that ionize, are trapped, then react with a warm (200 eV), dense tritium target plasma. This produces a neutron source strength of 3.6 x 10 17 n/sec for a neutron power density at the plasma edge of 5--10 MW/m 2 . This is several times the ∼2 MW/m 2 anticipated at the first wall of fusion reactors. This high flux provides accelerated end-of-life tests of 1- to 2-year duration, thus making materials development possible. The modular design of the source and the facilities are described

  5. Applications of focused MeV light ion beams for high resolution channeling contrast imaging

    Energy Technology Data Exchange (ETDEWEB)

    Jamieson, D N; Breese, M B.H.; Prawer, S; Dooley, S P; Allen, M G; Bettiol, A A; Saint, A [Melbourne Univ., Parkville, VIC (Australia). School of Physics; Ryan, C G [Commonwealth Scientific and Industrial Research Organisation (CSIRO), North Ryde, NSW (Australia). Div. of Exploration Geoscience

    1994-12-31

    The technique of Nuclear Microscopy, utilizing a focused ion probe of typically MeV H{sup +} or He{sup +} ions, can produce images where the contrast depends on typical Ion Beam Analysis (lBA) processes. The probe forming lens system usually utilizes strong focusing, precision magnetic quadrupole lenses and the probe is scanned over the target to produce images. Originally, this imaging technique was developed to utilize backscattered particles with incident beam currents typically of a few nA, and the technique became known as Channeling Contrast Microscopy (CCM). Recently, the technique has been developed further to utilize the forward scattering of ions incident along a major crystal axis in thin crystals. This technique is known as Channeling Scanning Transmission Ion Microscopy (CSTIM). Since nearly all incident ions are detected, CSTIM is highly efficient and very low beam currents are sufficient for imaging, typically as low as a few fA. This allows probes as small as 50 nm to be used. In this paper we briefly review the recent applications of these emerging techniques to a variety of single crystal materials (authors). 13 refs., 5 figs.

  6. Applications of focused MeV light ion beams for high resolution channeling contrast imaging

    Energy Technology Data Exchange (ETDEWEB)

    Jamieson, D.N.; Breese, M.B.H.; Prawer, S.; Dooley, S.P.; Allen, M.G.; Bettiol, A.A.; Saint, A. [Melbourne Univ., Parkville, VIC (Australia). School of Physics; Ryan, C.G. [Commonwealth Scientific and Industrial Research Organisation (CSIRO), North Ryde, NSW (Australia). Div. of Exploration Geoscience

    1993-12-31

    The technique of Nuclear Microscopy, utilizing a focused ion probe of typically MeV H{sup +} or He{sup +} ions, can produce images where the contrast depends on typical Ion Beam Analysis (lBA) processes. The probe forming lens system usually utilizes strong focusing, precision magnetic quadrupole lenses and the probe is scanned over the target to produce images. Originally, this imaging technique was developed to utilize backscattered particles with incident beam currents typically of a few nA, and the technique became known as Channeling Contrast Microscopy (CCM). Recently, the technique has been developed further to utilize the forward scattering of ions incident along a major crystal axis in thin crystals. This technique is known as Channeling Scanning Transmission Ion Microscopy (CSTIM). Since nearly all incident ions are detected, CSTIM is highly efficient and very low beam currents are sufficient for imaging, typically as low as a few fA. This allows probes as small as 50 nm to be used. In this paper we briefly review the recent applications of these emerging techniques to a variety of single crystal materials (authors). 13 refs., 5 figs.

  7. Prototype Digital Beam Position and Phase Monitor for the 100-MeV Proton Linac of PEFP

    CERN Document Server

    Yu In Ha; Kim, Sung-Chul; Park, In-Soo; Park, Sung-Ju; Tae Kim, Do

    2005-01-01

    The PEFP (Proton Engineering Frontier Project) at the KAERI (Korea Atomic Energy Research Institute) is building a high-power proton linear accelerator aiming to generate 100-MeV proton beams with 20-mA peak current (pulse width and max. repetition rate of 1 ms and 120 Hz respectively). We are developing a prototype digital BPPM (Beam Position and Phase Monitor) for the PEFP linac utilizing the digital technology with field programmable gate array (FPGA). The RF input signals are down converted to 10 MHz and sampled at 40 MHz with 14-bit ADC to produce I and Q data streams. The system is designed to provide a position and phase resolution of 0.1% and 0.1? RMS respectively. The fast digital processing is networked to the EPICS-based control system with an embedded processor (Blackfin). In this paper, the detailed description of the prototype digital beam position and phase monitor will be described with the performance test results.

  8. Field test results for radioactive waste drum characterization with Waste Inspection Tomography (WIT)

    Energy Technology Data Exchange (ETDEWEB)

    Bernardi, R.T. [Bio-Imaging Research, Inc., Lincolnshire, IL (United States)

    1997-11-01

    This paper summarizes the design, fabrication, factory testing, evaluation and demonstration of waste inspection tomography (WIT). WIT consists of a self-sufficient, mobile semi-trailer for Non-Destructive Evaluation and Non-Destructive Assay (NDE/NDA) characterization of nuclear waste drums using X-ray and gamma-ray tomographic techniques. The 23-month WIT Phase I initial test results include 2 MeV Digital Radiography (DR), Computed Tomography (CT), Anger camera imaging, Single Photon Emission Computed Tomography (SPECT), Gamma-Ray Spectroscopy, Collimated Gamma Scanning (CGS), and Active and Passive Computed Tomography (A&PCT) using a 1.4 mCi source of {sup 166}Ho. These techniques were initially demonstrated on a 55-gallon phantom drum with three simulated waste matrices of combustibles, heterogeneous metals, and cement using check sources of gamma active isotopes. Waste matrix identification, isotopic identification, and attenuation-corrected gamma activity determination were all demonstrated nondestructively and noninvasively. Preliminary field tests results with nuclear waste drums are summarized. WIT has inspected drums with 0 to 20 grams plutonium 239. The minimum measured was 0.131 gram plutonium 239 in cement. 8 figs.

  9. Residual Nuclides Induced in Cu Target by a 250 MeV Proton Beam

    International Nuclear Information System (INIS)

    Zhang Hong-Bin; Zhang Xue-Ying; Ma Fei; Ju Yong-Qin; Ge Hong-Lin; Chen Liang; Zhang Yan-Bin; Li Yan-Yan; Luo Peng; Wang Jian-Guo; Wan Bo; Xu Xiao-Wei; Wei Ji-Fang; Zhou Bin

    2015-01-01

    Residual nuclide production is studied experimentally by bombarding a Cu target with a 250 MeV proton beam. The data are measured by the off-line γ-spectroscopy method. Six nuclides are identified and their cross sections are determined. The corresponding calculated results by the MCNPX and GEANT4 codes are compared with the experimental data to check the validity of the codes. A comparison shows that the MCNPX simulation has a better agreement with the experiment. The energy dependence of residual nuclide production is studied with the aid of MCNPX simulation, and it is found that the mass yields for the nuclides in the light mass region increase significantly with the proton energy. (paper)

  10. Thermoluminescent response of LiF: Mg, Cu, P (GR-200) below an electron beam of 6 MeV

    International Nuclear Information System (INIS)

    Torijano C, E.F.S.; Azorin N, J.; Villasenor N, I.; Lujan C, P.J.; Rivera M, T.

    2007-01-01

    Full text: In this work the experimental results of studying the thermoluminescent response (TL) of LiF:Mg,Cu,P (GR-200) previously irradiated with 6 MeV electrons are presented. The electrons beam was generated by a Lineal Accelerator VARIAN I for medical use. The lineal accelerator is installed in the General Hospital of Mexico (HGM). A lot of 25 thermoluminescent dosemeters (DTL) was used. The mass and volume of each one of them were determined. Obtaining a variation of 14% in standard deviation (SD). The DTLs were irradiated to an energy of 6 MeV. The dose given to the DTL was of 50 c Gy. The linearity of the response of the GR-200 also was determined. (Author)

  11. Commissioning of a compact laser-based proton beam line for high intensity bunches around 10Â MeV

    Science.gov (United States)

    Busold, S.; Schumacher, D.; Deppert, O.; Brabetz, C.; Kroll, F.; Blažević, A.; Bagnoud, V.; Roth, M.

    2014-03-01

    We report on the first results of experiments with a new laser-based proton beam line at the GSI accelerator facility in Darmstadt. It delivers high current bunches at proton energies around 9.6 MeV, containing more than 109 particles in less than 10 ns and with tunable energy spread down to 2.7% (ΔE/E0 at FWHM). A target normal sheath acceleration stage serves as a proton source and a pulsed solenoid provides for beam collimation and energy selection. Finally a synchronous radio frequency (rf) field is applied via a rf cavity for energy compression at a synchronous phase of -90 deg. The proton bunch is characterized at the end of the very compact beam line, only 3 m behind the laser matter interaction point, which defines the particle source.

  12. Machine development studies for PSB extraction at 160 MeV and PSB to PS beam transfer

    CERN Document Server

    Forte, V; Bartmann, W; Borburgh, J; Ferrero Colomo, A; Damerau, H; Di Giovanni, G P; Coralejo Feliciano, L M; Fraser, M A; Gamba, D; Mikulec, B; Guerrero Ollacarizqueta, A; Serluca, M; Sermeus, L; Sterbini, G

    2017-01-01

    This paper collects the machine development (MD) activities for the beam transfer studies in 2016 concerning the PSB extraction and the PSB-to-PS transfer. Many topics are covered: from the 160 MeV extraction from the PSB, useful for the future commissioning activities after the connection with Linac4, to new methodologies for measuring the magnetic waveforms of kickers and dispersion reduction schemes at PS injection, which are of great interest for the LHC Injectors Upgrade (LIU) [1] project.

  13. Polarization measurements for P-12C elastic scattering between 40-75 MeV

    International Nuclear Information System (INIS)

    Kato, S.; Okada, K.; Kondo, M.; Shimizu, A.; Hosono, K.; Saito, T.; Matsuoka, N.; Nagamachi, S.; Nisimura, K.; Tamura, N.

    1980-01-01

    Absolute values of the polarization in p- 12 C elastic scattering have been measured at 60.0 and 64.5 MeV at 47.5 0 in the laboratory system using a double scattering method and a method to measure an asymmetry with a polarized beam. The results are P(60.0 MeV, 47.5 0 ) = 0.965 +- 0.011 and P(64.5 MeV, 47.5 0 ) = 0.975 +- 0.011. Based on these values, the polarization measurements have been extended to the energy range from 40-75 MeV at several angles around 47.5 0 using the polarized proton beam and the energy degrader. Differential cross sections and polarizations from 15-115 0 are also presented at 65 MeV. These data will be valuable for the monitoring of beam polarization in this energy region. (orig.)

  14. A 30 MeV H- cyclotron for isotope production

    International Nuclear Information System (INIS)

    Milton, B.F.; Dawson, R.; Erdman, K.L.

    1989-05-01

    Because of an expanding market for radioisotopes there is a need for a new generation of cyclotrons designed specifically for this purpose. TRIUMF is cooperating with a local industrial company in designing and constructing such a cyclotron. It will be a four sector H - cyclotron, exploiting the newly developed high brightness multicusp ion source. This source with H - current capability in excess of 5 mA makes feasible accelerated H - beam intensities of up to 500 μA. Beam extraction is by stripping to H + in a thin graphite foil. Extraction of two high-intensity beams, with energy variable from 15 to 30 MeV is planned. The use of an external ion source, provision of a good vacuum in the acceleration region, and the careful choice of materials for components in the median plane leads to a cyclotron that will have low activation and can be easily serviced in spite of the very high operating beam intensities. A design extension to 70 MeV using many of the design features of the 30 MeV cyclotron can be easily made. Such a machine with a good quality variable energy beam is a highly desirable source of protons for isotope production, injection into higher energy high intensity acceleration, injection into higher energy high intensity accelerators, and as an irradiation facility for ocular melanomas. Design of the 30 MeV cyclotron is well advanced and construction is in progress

  15. Design study of the ESS-Bilbao 50 MeV proton beam line for radiobiological studies

    Energy Technology Data Exchange (ETDEWEB)

    Huerta-Parajon, M., E-mail: mhuerta@essbilbao.org; Martinez-Ballarin, R., E-mail: rmartinez@essbilbao.org; Abad, E., E-mail: eabad@essbilbao.org

    2015-02-01

    The ESS-Bilbao proton accelerator facility has been designed fulfilling the European Spallation Source (ESS) specifications to serve as the Spanish contribution to the ESS construction. Furthermore, several applications of the ESS-Bilbao proton beam are being considered in order to contribute to the knowledge in the field of radiobiology, materials and aerospace components. Understanding of the interaction of radiation with biological systems is of vital importance as it affects important applications such as cancer treatment with ion beam therapy among others. ESS-Bilbao plans to house a facility exclusively dedicated to radiobiological experiments with protons up to 50 MeV. Beam line design, optimisation and initial calculations of flux densities and absorbed doses were undertaken using the Monte Carlo simulation package FLUKA. A proton beam with a flux density of about 10{sup 6} protons/cm{sup 2} s reaches the water sample with a flat lateral distribution of the dose. The absorbed dose at the pristine Bragg peak calculated with FLUKA is 2.4 ± 0.1 Gy in 1 min of irradiation time. This value agrees with the clinically meaningful dose rates, i.e. around 2 Gy/min, used in hadrontherapy. Optimisation and validation studies in the ESS-Bilbao line for radiobiological experiments are detailed in this article.

  16. Design and performance of the 40 MeV linac and beam transport system for the 1 GeV synchrotron radiation source at SORTEC

    International Nuclear Information System (INIS)

    Shiota, M.; Hiraki, A.; Mizota, M.; Iida, T.; Haraguchi, M.; Kuno, K.; Nakamura, S.; Ohno, M.; Tomimasu, T.

    1990-01-01

    A 1 Gev synchrotron radiation source (SOR) system has been installed and is now being adjusted at SORTEC corporation. This paper reports the configuration and the beam test results of the 40 MeV electron linac (pre-injector) and the beam transport line to the electron synchrotron used in this system. The output beam from the linac must be low emittance, small energy spread, and stable in energy. The beam transport line must also efficiently lead the beam from the linac to the electron synchrotron. This linac produced the beam current of 130 mA, with an energy spread of 1.3 % (FWHM), and an emittance of 0.7 πmm·mrad. The beam characteristics were verified by various beam monitors on the beam transport line. (author)

  17. 50 MeV Run of the IOTA / FAST Electron Accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Edstrom Jr., D.; et al.

    2017-02-02

    The low-energy section of the photoinjector-based electron linear accelerator at the Fermilab Accelerator Science & Technology (FAST) facility was recently commissioned to an energy of 50 MeV. This linear accelerator relies primarily upon pulsed SRF acceleration and an optional bunch compressor to produce a stable beam within a large operational regime in terms of bunch charge, total average charge, bunch length, and beam energy. Various instrumentation was used to characterize fundamental properties of the electron beam including the intensity, stability, emittance, and bunch length. While much of this instrumentation was commissioned in a 20 MeV running period prior, some (including a new Martin- Puplett interferometer) was in development or pending installation at that time. All instrumentation has since been recommissioned over the wide operational range of beam energies up to 50 MeV, intensities up to 4 nC/pulse, and bunch structures from ~1 ps to more than 50 ps in length.

  18. Measurement of neutron production by 500 MeV proton beam

    International Nuclear Information System (INIS)

    Hirayama, Hideo; Ban, Shuichi

    1981-01-01

    Measurement of high energy neutrons is difficult, because the cross section data are scarce, the cross section at high energy is usually small, and the monoenergetic neutrons are hardly obtained. At the National Laboratory for High Energy Physics (KEK), various threshold detectors have been used for high energy neutron measurement. A carbon detector is a standard detector for high energy neutrons, since the cross section of the C 12 (n, 2n) C 11 reaction is almost constant at higher energy than 20 MeV, and the data have been well known. The half-life of the product (C 11 ) is about 20 min, and other activities with longer half-life than 1 min are restricted to Be 7 and C 11 . As a carbon detector, a plastic scintillator is used, and the neutron spectra observed at the Booster Beam Dump Room of KEK are presented. The results of measurements were compared with the calculated results using a Monte Carlo code made at KEK. Agreement between both results was good. (Kato, T.)

  19. Dose as a function of radial distance from a 930 MeV 4He ion beam

    International Nuclear Information System (INIS)

    Varma, M.N.; Paretzke, H.; Baum, J.W.; Lyman, J.T.; Howard, J.

    1975-01-01

    A unique mesh wall ionization chamber (approximating a wall-less ionization chamber) was used to measure dose as a function of radial distance from a 930 MeV 4 He ion beam in air. Measurements were made at distances from about 10 to 40 cm from the ion path. This represents simulated distances of approximately 102 to 404 μm in tissue having a density of 1 g/cm 3 . Experimental values are compared with theoretical calculations, and probable causes of differences found are discussed. (auth)

  20. Feasibility of Colliding-beam fast-fission reactor via 238U80++238 U80+ --> 4 FF + 5n + 430 MeV beam with suppressed plutonium and direct conversion of fission fragment (FF) energy into electricity and/or Rocket propellant with high specific impulse

    Science.gov (United States)

    Maglich, Bogdan; Hester, Tim; Calsec Collaboration

    2015-10-01

    Uranium-uranium colliding beam experiment1, used fully ionized 238U92+ at energy 100GeV --> accelerated through 3 MV accelerator, will collide beam 240 MeV --> 4 FF + 5n + 430 MeV. Using a simple model1 fission σf ~ 100 b. Suppression of Pu by a factor of 106 will be achieved because NO thermal neutron fission can take place; only fast, 1-3 MeV, where σabs is negligible. Direct conversion of 95% of 430 MeV produced is carried by electrically charged FFs which are magnetically funneled for direct conversion of energy of FFs via electrostatic decelerators4,11. 90% of 930 MeV is electrically recoverable. Depending on the assumptions, we project electric _ power density production of 20 to 200 MWe m-3, equivalent to Thermal 1.3 - 13 GWthm-3. If one-half of unburned U is used for propulsion while rest powers system, heavy FF ion mass provides specific impulse Isp = 106 sec., 103 times higher than current rocket engines.

  1. Observation of optical Smith-Purcell radiation at an electron beam energy of 855 MeV

    International Nuclear Information System (INIS)

    Kube, G.; Backe, H.; Euteneuer, H.; Grendel, A.; Hagenbuck, F.; Hartmann, H.; Kaiser, K.H.; Lauth, W.; Schoepe, H.; Wagner, G.; Walcher, Th.; Kretzschmar, M.

    2002-01-01

    Smith-Purcell radiation, generated when a beam of charged particles passes close to the surface of a diffraction grating, has been studied in the visible spectral range at wavelengths of 360 and 546 nm with the low emittance 855 MeV electron beam of the Mainz Microtron MAMI. The beam focused to a spot size of 4 μm (full width at half maximum) passed over optical diffraction gratings of echelle profiles with blaze angles of 0.8 deg., 17.27 deg., and 41.12 deg. and grating periods of 0.833 and 9.09 μm. Taking advantage of the specific emission characteristics of Smith-Purcell radiation a clear separation from background components, such as diffracted synchrotron radiation from upstream beam optical elements and transition radiation, was possible. The intensity scales with a modified Bessel function of the first kind as a function of the distance between electron beam and grating surface. Experimental radiation factors have been determined and compared with calculations on the basis of Van den Berg's theory [P.M. Van den Berg, J. Opt. Soc. Am. 63, 689 (1973)]. Fair agreement has been found for gratings with large blaze angles while the measurement with the shallow grating (blaze angle 0.8 deg.) is at variance with this theory. Finally, the optimal operational parameters of a Smith-Purcell radiation source in view of already existing powerful undulator sources are discussed

  2. Response of E. coli AB2463 recA to fast neutron beams with mean energies in the range 4 to 27 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Redpath, J L [Michael Reese Hospital, Chicago, Ill. (USA)

    1978-07-01

    The radiosensitivity of E.coli AB2463 recA, given as the reciprical of the mean lethal dose, Do/sup -1/, has been shown to be the same for four fast neutron beams with widely different energy spectra. It is proposed that this organism can be used to intercompare dosimetry on fast neutron beams with mean energies in the range 4 to 25 MeV with an accuracy of +- 5%.

  3. Construction of 100 MeV electron linac in Kyoto University

    International Nuclear Information System (INIS)

    Shirai, Toshiyuki; Sugimura, Takeshi; Kando, Masaki

    1995-01-01

    An electron linear accelerator and a compact storage ring have been constructed at Kyoto University. The beam energy of the storage ring is 300 MeV and will be utilized as a synchrotron radiation source. The output beam energy of the linac is 100 MeV and the designed beam current is 100 mA at the pulse width of 1 μsec. The construction of the linac had been finished and the test is under going. The electron beam of 300 mA is extracted from the electron gun and the peak RF power of 20 MW is successfully fed to the accelerating structures at the pulse width of 2 μsec. (author)

  4. The local distribution of radiation quality of a collimated fast neutron beam from 15 MeV deuterons on beryllium

    International Nuclear Information System (INIS)

    Fidorra, J.; Booz, J.

    1978-01-01

    The local distribution of radiation quality (ysub(F), ysub(D)) of a collimated fast neutron beam from 14 MeV deuterons on Beryllium was studied with a spherical 1/2 inch EG and G proportional counter simulating a diameter of 2μm. The deuterons were accelerated by the compact cyclotron CV-28 of the Kernforschungsanlage Juelich. The collimator was constructed by the Cyclotron Corporation. The mean neutron energy was 6 MeV. The measurements were performed in air and in a water phantom at a target skin distance of 125 cm. The energy deposition spectra of fast neutrons obtained at various positions were separated into three components of different radiation quality: the gamma component, the recoil proton component, and the heavy ion component

  5. Lactose and sucrose aqueous solutions for high-dose dosimetry with 10-MeV electron beam irradiation

    International Nuclear Information System (INIS)

    Amraei, R.; Kheirkhah, M.; Raisali, G.

    2012-01-01

    In the present study, dosimetric characterisation of aqueous solutions of lactose and sucrose was analysed by UV spectrometry following irradiation using 10-MeV electron beam at doses between 0.5 and 10.5 kGy. As a dosimetric index, absorbance is selected at 256 and 264 nm for lactose and sucrose aqueous solutions, respectively. The intensity of absorbance for irradiated solutions depends on the pre-irradiation concentration of lactose and sucrose. The post-irradiation stability of both solutions was investigated at room temperature for a measurement period of 22 d. (authors)

  6. Application of calorimeters for 5 MeV EB and bremsstrahlung dosimetry

    DEFF Research Database (Denmark)

    Sato, T.; Takahashi, T.; Saito, T.

    1993-01-01

    Graphite and water calorimeters, which were developed for use a 10 MeV electron beams (EB) at Riso National Laboratory, were used for process validation and routine dosimeter calibration at a 5 MeV EB. Water calorimeters were used for reference measurements for 5 MeV EB, the response was found...... to be directly proportional to the beam current and the variation among three water calorimeters was less than +/- 2 % in the range of 10 to 40 kGy. CTA, PMMA, RCD dosimeters were calibrated by irradiating the dosimeters and water calorimeters Simultaneously. The water calorimeter was proved to be an useful tool...... at 5 MeV EB. Graphite calorimeters gave reproducible readings within 3.3 % relative errors (95 % confidence level) for X-ray measurement....

  7. Application of calorimeters for 5 MeV EB and bremsstrahlung dosimetry

    International Nuclear Information System (INIS)

    Sato, Toshio; Takahashi, Toru; Saito, Toshio; Takehisa, Masaaki; Miller, A.

    1993-01-01

    Graphite and water calorimeters, which were developed for use with 10 MeV electron beams (EB) at Riso National Laboratory, were used for process validation and routine dosimeter calibration at a 5 MeV EB. Water calorimeters were used for reference measurements for 5 MeV EB, the response was found to be directly proportional to the beam current and the variation among three water calorimeters was less than ± 2% in the range of 10 to 40 kGy. CTA PMMA RCD dosimeters were calibrated by irradiating the dosimeters and water calorimeters simultaneously. The water calorimeter was proved to be an useful tool at 5 MeV EB. Graphite calorimeters gave reproducible readings within 3.3 % relative errors (95% confidence level) for X-ray measurement. (Author)

  8. The 200 MeV cyclotron facility

    International Nuclear Information System (INIS)

    1987-01-01

    Beams of protons with several different energies have now been successfully transported between the injector cyclotron SPC1 and the SSC. Some small modifications to the placement of steering magnets and diagnostic equipment have been made in the light of our operational experience, which should improve the ease of tuning this beamline. Proton beams up to 200 MeV in energy have been transported to the experimental areas, where experiments in nuclear physics have been successful conducted. Three of the experimental beamlines are now in operation. Beams of 66 MeV protons have also been transported to targets in the isotope production vault, without difficulty. Field mapping of the remaining quadrupoles on site has been completed. Installation of and alignment of magnets up to the beam swinger is also complete, although the beam tube itself, plus vacuum and diagnostic equipment must still be tackled. The beam swinger has been designed and detailed in the drawing office, and is now being manufactured locally. The beamline elements for the sepctrometer beamline remain to be purchased. A personal computer has been purchased for controlling the field-mapping equipment for the spectrometer magnets, which are being manufactured in this country. A number of computer programs have been written for conversion of calibrated quadrupole and dipole magnet field data to absolute current values for the control system. Other programs permit diagnostic measurements of beam profiles to be used to calculated the beam emittance, or to set steering magnets so that the beam is correctly aligned

  9. Interaction of a 29 MeV 3He particle beam with a Cl4C vapour target

    International Nuclear Information System (INIS)

    Lleo Morilla, A.

    1963-01-01

    The interactions of a 29 MeV 3 H e particles beam on a Cl 4 C vapour target have been studied using the photographic method. differential cross-sections for the Cl( 3 He, 3 He)Cl elastic scattering and 1 2C( 3 He, α) 1 1C pick-up reaction are shown; the corresponding angular distributions in the centre-of-mass system have been compared with the predictions of optical model and A.B.M. theories. (Author) 21 refs

  10. Bringing up beams

    CERN Multimedia

    Katarina Anthony

    2013-01-01

    Last month, commissioning began on CERN’s newest linear accelerator: Linac4. As the replacement machine for Linac2, Linac4 will take a negative hydrogen ion beam to a staggering 160 MeV. We check in to see how the Linac4 team is preparing its machine for its new role as the first link in the accelerator chain.   The Linac4 3 MeV beam line, with the ion source in the back, the RFQ in the middle and the chopping line in the front. On 14 November, members of the Linac4 collaboration and the CERN Operations Group were brought together for their first “real day” in the Linac4 Control Room. Together, they successfully accelerated their first hydrogen ion beam to 3 MeV. It was an exciting moment for everyone involved and marked the start of one of the most critical commissioning phases for the new accelerator. At the start of the Linac4 beam line sits the CERN-made Radio Frequency Quadrupole (RFQ). This vital piece of machinery takes the beam from 45 keV to 3 MeV in ju...

  11. Linac4 crosses the 100 MeV threshold

    CERN Multimedia

    Corinne Pralavorio

    2016-01-01

    The new linear accelerator, which from 2020 will be the first link in the accelerator chain, has entered a new stage of its commissioning.   Members of the team in charge of the commissioning of Linac4 in the accelerator’s control room. A few hours earlier, Linac4 accelerated a beam to 107 MeV for the first time. We couldn’t have imagined a more appropriate date: on 1 July (1.07), Linac4 reached an energy of 107 MeV. Having crossed the 100 MeV barrier, the linear accelerator is now on the home straight of its commissioning. “This stage was very quick – it took less than two weeks,” says Alessandra Lombardi, deputy project leader of Linac4, in charge of the commissioning. In 2020, Linac4 will replace the existing Linac2 as the first link in the accelerator chain. It will accelerate beams of H- ions (protons surrounded by two electrons) to 160 MeV, compared to 50 MeV with Linac2. The new machine is particularly sophisticated as it comprises...

  12. Negative ion beam processes

    International Nuclear Information System (INIS)

    Hayward, T.D.; Lawrence, G.P.; Bentley, R.F.; Malanify, J.J.; Jackson, J.A.

    1975-06-01

    Los Alamos Scientific Laboratory fiscal year 1975 work on production of intense, very bright, negative hydrogen (H - ), ion beams and conversion of a high-energy (a few hundred MeV) negative beam into a neutral beam are described. The ion source work has used a cesium charge exchange source that has produced H - ion beams greater than or equal to 10 mA (about a factor of 10 greater than those available 1 yr ago) with a brightness of 1.4 x 10 9 A/m 2 -rad 2 (about 18 times brighter than before). The high-energy, neutral beam production investigations have included measurements of the 800-MeV H - -stripping cross section in hydrogen gas (sigma/sub -10/, tentatively 4 x 10 -19 cm 2 ), 3- to 6-MeV H - -stripping cross sections in a hydrogen plasma (sigma/sub -10/, tentatively 2 to 4 x 10 -16 cm 2 ), and the small-angle scattering that results from stripping an 800-MeV H - ion beam to a neutral (H 0 ) beam in hydrogen gas. These last measurements were interrupted by the Los Alamos Meson Physics Facility shutdown in December 1974, but should be completed early in fiscal year 1976 when the accelerator resumes operation. Small-angle scattering calculations have included hydrogen gas-stripping, plasma-stripping, and photodetachment. Calculations indicate that the root mean square angular spread of a 390-MeV negative triton (T - ) beam stripped in a plasma stripper may be as low as 0.7 μrad

  13. Development of BPM/BLM DAQ System for KOMAC Beam Line

    Energy Technology Data Exchange (ETDEWEB)

    Song, Young-Gi; Kim, Jae-Ha; Yun, Sang-Pil; Kim, Han-Sung; Kwon, Hyeok-Jung; Cho, Yong-Sub [Korea Atomic Energy Research Institute, Gyeongju (Korea, Republic of)

    2016-10-15

    The proton beam is accelerated from 3 MeV to 100 MeV through 11 DTL tanks. The KOMAC installed 10 beam lines, 5 for 20-MeV beams and 5 for 100-MeV beams. The proton beam is transmitted to two target room. The KOMAC has been operating two beam lines, one for 20 MeV and one for 100 MeV. New beam line, RI beam line is under commissioning. A Data Acquisition (DAQ) system is essential to monitor beam signals in an analog front-end circuitry from BPM and BLM at beam lines. A data acquisition (DAQ) system is essential to monitor beam signals in an analog front-end circuitry from BPM and BLM at beam lines. The DAQ digitizes beam signal and the sampling is synchronized with a reference signal which is an external trigger for beam operation. The digitized data is accessible by the Experimental Physics and Industrial Control System (EPICS)-based control system, which manages the whole accelerator control. The beam monitoring system integrates BLM and BPM signals into the control system and offers realtime data to operators. The IOC, which is implemented with Linux and a PCI driver, supports data acquisition as a very flexible solution.

  14. Measurement of neutron yield by 62 MeV proton beam on a thick Beryllium target

    International Nuclear Information System (INIS)

    Alba, R; Cosentino, G; Zoppo, A Del; Pietro, A Di; Figuera, P; Finocchiaro, P; Maiolino, C; Santonocito, D; Schillaci, M; Barbagallo, M; Colonna, N; Boccaccio, P; Esposito, J; Celentano, A; Osipenko, M; Ricco, G; Ripani, M; Viberti, C M; Kostyukov, A

    2013-01-01

    In the framework of research on IVth generation reactors and high intensity neutron sources a low-power prototype neutron amplifier was recently proposed by INFN. It is based on a low-energy, high current proton cyclotron, whose beam, impinging on a thick Beryllium converter, produces a fast neutron spectrum. The world database on the neutron yield from thick Beryllium target in the 70 MeV proton energy domain is rather scarce. The new measurement was performed at LNS, covering a wide angular range from 0 to 150 degrees and an almost complete neutron energy interval. In this contribution the preliminary data are discussed together with the proposed ADS facility.

  15. An in-beam PET system for monitoring ion-beam therapy: test on phantoms using clinical 62 MeV protons

    Science.gov (United States)

    Camarlinghi, N.; Sportelli, G.; Battistoni, G.; Belcari, N.; Cecchetti, M.; Cirrone, G. A. P.; Cuttone, G.; Ferretti, S.; Kraan, A.; Retico, A.; Romano, F.; Sala, P.; Straub, K.; Tramontana, A.; Del Guerra, A.; Rosso, V.

    2014-04-01

    Ion therapy allows the delivery of highly conformal dose taking advantage of the sharp depth-dose distribution at the Bragg-peak. However, patient positioning errors and anatomical uncertainties can cause dose distortions. To exploit the full potential of ion therapy, an accurate monitoring system of the ion range is needed. Among the proposed methods to monitor the ion range, Positron Emission Tomography (PET) has proven to be the most mature technique, allowing to reconstruct the β+ activity generated in the patient by the nuclear interaction of the ions, that can be acquired during or after the treatment. Taking advantages of the spatial correlation between positron emitters created along the ions path and the dose distribution, it is possible to reconstruct the ion range. Due to the high single rates generated during the beam extraction, the acquisition of the β+ activity is typically performed after the irradiation (cyclotron) or in between the synchrotron spills. Indeed the single photon rate can be one or more orders of magnitude higher than normal for cyclotron. Therefore, acquiring the activity during the beam irradiation requires a detector with a very short dead time. In this work, the DoPET detector, capable of sustaining the high event rate generated during the cyclotron irradiation, is presented. The capability of the system to acquire data during and after the irradiation will be demonstrated by showing the reconstructed activity for different PMMA irradiations performed using clinical dose rates and the 62 MeV proton beam at the CATANA-LNS-INFN. The reconstructed activity widths will be compared with the results obtained by simulating the proton beam interaction with the FLUKA Monte Carlo. The presented data are in good agreement with the FLUKA Monte Carlo.

  16. An in-beam PET system for monitoring ion-beam therapy: test on phantoms using clinical 62 MeV protons

    International Nuclear Information System (INIS)

    Camarlinghi, N; Sportelli, G; Belcari, N; Cecchetti, M; Ferretti, S; Kraan, A; Retico, A; Straub, K; Guerra, A Del; Rosso, V; Battistoni, G; Sala, P; Cirrone, G A P; Cuttone, G; Romano, F; Tramontana, A

    2014-01-01

    Ion therapy allows the delivery of highly conformal dose taking advantage of the sharp depth-dose distribution at the Bragg-peak. However, patient positioning errors and anatomical uncertainties can cause dose distortions. To exploit the full potential of ion therapy, an accurate monitoring system of the ion range is needed. Among the proposed methods to monitor the ion range, Positron Emission Tomography (PET) has proven to be the most mature technique, allowing to reconstruct the β + activity generated in the patient by the nuclear interaction of the ions, that can be acquired during or after the treatment. Taking advantages of the spatial correlation between positron emitters created along the ions path and the dose distribution, it is possible to reconstruct the ion range. Due to the high single rates generated during the beam extraction, the acquisition of the β + activity is typically performed after the irradiation (cyclotron) or in between the synchrotron spills. Indeed the single photon rate can be one or more orders of magnitude higher than normal for cyclotron. Therefore, acquiring the activity during the beam irradiation requires a detector with a very short dead time. In this work, the DoPET detector, capable of sustaining the high event rate generated during the cyclotron irradiation, is presented. The capability of the system to acquire data during and after the irradiation will be demonstrated by showing the reconstructed activity for different PMMA irradiations performed using clinical dose rates and the 62 MeV proton beam at the CATANA-LNS-INFN. The reconstructed activity widths will be compared with the results obtained by simulating the proton beam interaction with the FLUKA Monte Carlo. The presented data are in good agreement with the FLUKA Monte Carlo

  17. 3 MeV DC accelerator, EBC Kharghar

    International Nuclear Information System (INIS)

    Bakhtsingh, R.I.; Acharya, S.

    2017-01-01

    The Accelerator and Pulse Power Division (APPD) has designed and developed a 3 MeV, 10 mA DC electron beam accelerator at Electron Beam Centre, Kharghar, Navi Mumbai. This machine has been utilized for reduction of SO_x and NO_x in simulated flue gases and treatment of waste water to reduce COD and BOD

  18. 0,01-5 MeV heavy ion accelerators

    International Nuclear Information System (INIS)

    Golubev, V.P.; Ivanov, A.S.; Nikiforov, S.A.; Svin'in, M.P.; Tarvid, G.V.; Troshikhin, A.G.; Fedotov, M.T.

    1983-01-01

    The results of development of an accelerating complex on the base of the UP-2-1 heavy ion charge exchange accelerator and IMPLANT-500 high-voltage heavy ion accelerator are given. The accelerating complex provides overlapping of the 0.01 MeV to 5 MeV energy range at accelerated beam currents of 10 -3 -10 -6 A order. The structural features of accelerators and their basic units and systems are considered. The UP-2-1 accelerator is designed for researches in the field of experimental physics and applied problem solutions. The IMPLANT-500 accelerator is designed for commercial ion-beam facilities with closed loop of silicon plate treatment

  19. Construction of 35 MeV DSM at Nihon University

    International Nuclear Information System (INIS)

    Hayakawa, K.; Sato, K.; Tanaka, T.; Takeda, O.

    1988-01-01

    High quality electron beam is needed for the excitation of the free electron laser(FEL). Construction of the 35 MeV double-sided microtron for the FEL has been started at 1984. This accelerator will feed a electron beam which has narrow energy width and low emittance. A first one turn beam line has been completed. Beam accelerating experiments and high power microwave tests are performed. (author)

  20. NSLS 3: Conceptual design report: 750 MeV e+ or e- injector

    International Nuclear Information System (INIS)

    1986-05-01

    The 750 MeV positron or electron injector is comprised of an electron linear accelerator which accelerates an intense beam of electrons to an energy of about 250 MeV, a positron converter, a second linear accelerator that boosts the final positron energy to 750 MeV, and a damping ring in which radiation damping is used to reduce the emittance of the positron beam for injection into the storage rings. The reasons for the need of a new injector are enumerated. The conceptual design of the system and its component systems are described, as well as project cost, schedule, and manpower requirements

  1. Novel digital K-edge imaging system with transition radiation from an 855-MeV electron beam

    CERN Document Server

    Hagenbuck, F; Clawiter, N; Euteneuer, H; Görgen, F; Holl, P; Johann, K; Kiser, K H; Kemmer, J; Kerschner, T; Kettig, O; Koch, H; Kube, G; Lauth, W; Mauhay, H; Schütrumpf, M; Stotter, R; Strüder, L; Walcher, T; Wilms, A; von Zanthier, C; Zemter, M

    2001-01-01

    A novel K-edge imaging method has been developed at the Mainz Microtron MAMI aiming at a very efficient use of the transition radiation (TR) flux generated by the external 855-MeV electron beam in a foil stack. A fan-like quasi-monochromatic hard X-ray beam is produced from the +or-1-mrad-wide TR cone with a highly oriented pyrolytic graphite (HOPG) crystal. The absorption of the object in front of a 30 mm*10 mm pn charge-coupled device (pn-CCD) photon detector is measured at every pixel by a broad-band energy scan around the K-absorption edge. This is accomplished by a synchronous variation of the lateral crystal position and the electron beam direction which defines also the direction of the TR cone. The system has been checked with a phantom consisting of a 2.5- mu m thick molybdenum sample embedded in a 136- or 272- mu m-thick copper bulk foil. A numerical analysis of the energy spectrum for every pixel demonstrates that data as far as +or-0.75 keV away from the K edge of molybdenum at 20 keV still improv...

  2. MeV He microbeam analysis of a semiconductor integrated circuit

    International Nuclear Information System (INIS)

    Zhu Peiran; Liu Jiarui; Zhang Jinping; Yin Shiduan

    1989-01-01

    An MeV He + microbeam has been used to analyse a microscale semiconductor structure. The 2 MeV He + ion beam is limited to 25 μm diameter by a set of diaphragms and is further focused by a quadrupole quadruplet to 3μm diameter. The incident beam current on the sample is about 0.3 nA. The Rutherford backscattering (RBS) technique is applied to the measurement of the composition and depth profile in the near-surface region of a semiconductor integrated circuit. (author)

  3. MeV He microbeam analysis of a semiconductor integrated circuit

    Energy Technology Data Exchange (ETDEWEB)

    Zhu Peiran; Liu Jiarui; Zhang Jinping; Yin Shiduan

    1989-01-01

    An MeV He/sup +/ microbeam has been used to analyse a microscale semiconductor structure. The 2 MeV He/sup +/ ion beam is limited to 25 /mu/m diameter by a set of diaphragms and is further focused by a quadrupole quadruplet to 3/mu/m diameter. The incident beam current on the sample is about 0.3 nA. The Rutherford backscattering (RBS) technique is applied to the measurement of the composition and depth profile in the near-surface region of a semiconductor integrated circuit.

  4. Operation of the APEX photoinjector accelerator at 40 MeV

    International Nuclear Information System (INIS)

    Feldman, D.W.; Bender, S.C.; Byrd, D.A.; Carlsten, B.E.; Early, J.W.; Feldman, R.B.; Goldstein, J.C.; Martineau, R.L.; O'Shea, P.G.; Pitcher, E.J.; Schmitt, M.J.; Stein, W.E.; Wilke, M.D.; Zaugg, T.J.

    1992-01-01

    We have successfully operated the photoinjector and rf linear accelerator for the Los Alamos APEX free electron laser (FEL) at design energy, average macropulse current, and emittance. The accelerator, which operates at 1.3 GHz, consists of a 6 MeV photoinjector and three standing-wave structures with a total beam energy of 40 MeV. This paper presents performance characteristics of the APEX system. The results show that this technology is capable of providing reliable, high-peak current, ultra-high brightness electron beams

  5. Beam line design using G4BeamLine

    CERN Document Server

    Dogan, Arda

    2014-01-01

    In Turkey in Ankara TAEK SANAEM Proton Accelerator Facility (PAF), there is a cyclotron which produces a focused intense 30 MeV proton beam and sends this beam to four different arms, three of which uses this beam to produce pharmaceutical medicine. The remaining one is spared for R&D purposes and the idea was to use these protons coming out from the fourth arm to use space radiation tests, which cannot be done in Turkey at the moment. However, according to SCC 25100 standards which is for 30 MeV protons, the beam coming out of cyclotron is too intense and focused to use for space radiation tests. Therefore, the main aim of my project is to design a beam line which will defocus the beam and reduce the flux so that the space radiation tests can be done according to the standards of SCC 25100.

  6. Simulation of energy deposit distribution in water for 10 and 25 MeV electron beams

    International Nuclear Information System (INIS)

    Borrell Carbonell, Maria de los Angeles.

    1977-01-01

    The Monte Carlo method was applied to transport simulation of electron beams from the exit window of a linear accelerator till the absorption by a water phantom. The distribution of energy deposit is calculated for ideal apparatus and experimental conditions. Calculations are made for a distance window-water surface of one meter, for 10 and 25 MeV monoenergetic incident electrons, and for different fields (15x15 cm 2 to 4x4 cm 2 ). Comparisons with experimental measurements obtained in comparable conditions with a Sagittaire accelerator (C.G.R.-MeV), show a good agreement concerning radial distribution and depth distribution around isodose 100%. However a certain disagreement appears in the end of depth penetration [fr

  7. Study of electrostatic acceleration of H and D negative ion beams. Application to the 1 MeV SINGAP accelerator; Etude de l`acceleration electrostatique de faisceaux d`ions negatifs H / D de haute puissance. Application a l`accelerateur SINGAP de 1MeV

    Energy Technology Data Exchange (ETDEWEB)

    Bucalossi, J [Association Euratom-CEA Cadarache, 13 - Saint-Paul-lez-Durance (France). Dept. de Recherches sur la Fusion Controlee; [Paris-6 Univ., 75 (France)

    1998-04-01

    In the framework of the development of a neutral beam injection system for ITER (International Thermonuclear Experimental Reactor), the electrostatic acceleration of negative ion H/D beams up to an energy of 1 MeV has been studied. With the support of 3-D beam trajectory calculations, the limitations of the multi-aperture multi-grid acceleration concept, ITER reference concept, ar shown and the relevance of a new concept, called SINGAP, is demonstrated. In a SINGAP accelerator, beamlets are pre-accelerated with a classical triode multi-apertures system up to {approx} 50 keV. The pre-accelerated beamlets are then merged into a single beam and post-accelerated at high energy through a large SINGle APerture using one SINgle GAP. The optics of one pre-accelerated beamlet has been studied on the INCA triode accelerator at the Ecole Polytechnique. A diagnostic has been developed to measure the emittance of the pre-accelerated beamlet. A diagnostic has been developed to measure the emittance of the pre-accelerated beamlet. Values of {approx} 0.03{pi}.mrad.cm for the effective normalized emittance and {approx} 12 mrad for the minimal beam divergence have been found (Hbeams). Besides, the effects of co-extracted electrons and pressure in the transport region on the beam optics are shown and experiment is compared to beam numerical simulation. On the Cadarache 1 MeV, 100 mA, D- SINGAP accelerator, beams of 1 s pulse were produced at a level of 900 keV (without observing breakdowns between electrodes). SINGAP optics has been investigated using an infrared calorimetric beam profile diagnostic (2-D) and a neutral beam profile diagnostic (1-D). The control of the beam optics is very satisfying: a divergence of {approx} 10 mrad has been measured, and 3-D simulations and experimentation are in good agreement. (author) 117 refs.

  8. Degradation Of Aggregate Pollutant In Textiles Wastewater By Electron Beam Irradiation

    International Nuclear Information System (INIS)

    Khomsaton Abu Bakar; Zulkafli Ghazali; Siti Aiasah Hashim; Selambakkannu, S.; Ming, T.T.; Natasha Isnin; Hasnul Nizam Osman; Khasmidatul Akma Mohd Khairul Azmi

    2016-01-01

    Aggregate pollutant were refer to the mixture of the excess material that is used in the manufacturing proses of textiles, present in wastewater. This paper studies the effect of the beam energy, beam current and absorbed dose on degradation of aggregate pollutant in textiles effluent which was indicate by COD, pH and UV-Vis spectrum. The impact of beam energy was conducted when sample were exposed to the irradiation at various beam energy (1 to 3 MeV) at 20 mA and 17 kGy. The COD reduced from 495 mg/l to the range 398.00 -358 mg/l at beam energy 1 MeV to 3 MeV. The irradiated sample also slightly become more acidic at higher beam energy. While 1 MeV beam energy was sufficient to eliminate the exposed peak at wavelength of 425 nm, 550 nm and 650 nm in the UV spectrum. In the case effect of current, the COD effluent tested at constant beam energy of 1 MeV and 3 MeV at various beam current (3 mA, 5 mA, 10 mA, 15 mA and 20 mA) decreased with higher beam current. While interested peak in UV spectrum of irradiated samples was varnish at 3 mA beam current and 1 MeV energy applied. Considering to the 19.66 % COD removal and electric power used, 1 MeV beam energy and 20 mA beam current was the optimum irradiation parameter selected for this study. At 1 MeV:20 mA textiles wastewater irradiated at various dose of 17, 20, 25, 30, 35, 100 and 200 kGy shows removal of COD, were in the range 4.42 % - 30.09 %. (author)

  9. Design of a 120 MeV $H^{-}$ Linac for CERN High-Intensity Applications

    CERN Document Server

    Gerigk, F

    2002-01-01

    The SPL (Superconducting Proton Linac) study at CERN foresees the construction of a 2.2 GeV linac as a high beam-power driver for applications such as a second-generation radioactive ion beam facility or a neutrino superbeam. At the same time such a high-performance injector would both modernize and improve the LHC injection chain. The 120 MeV normal-conducting section of the SPL could be used directly in a preliminary stage for H- charge-exchange injection into the PS Booster. This would increase the proton flux to the CERN experiments while also improving the quality and reliability of the beams for the LHC. The 120 MeV linac consists of a front-end, a conventional Drift Tube Linac (DTL) to 40 MeV and a Cell Coupled Drift Tube Linac (CCDTL) to the full energy. All the RF structures will operate at 352 MHz, using klystrons and RF equipment recovered from the LEP collider. This paper concentrates on the design of the 3 to 120 MeV section. It introduces the design criteria for high-stability beam optics and th...

  10. Neutron-neutron quasifree scattering in nd breakup at 10 MeV

    Directory of Open Access Journals (Sweden)

    Malone R.C.

    2016-01-01

    We are conducting new measurements of the cross section for nn QFS in nd breakup. The measurements are performed at incident neutron beam energies below 20 MeV. The neutron beam is produced via the 2H(d, n3He reaction. The target is a deuterated plastic cylinder. Our measurements utilize time-of-flight techniques with a pulsed neutron beam and detection of the two emitted neutrons in coincidence. A description of our initial measurements at 10 MeV for a single scattering angle will be presented along with preliminary results. Also, plans for measurements at other energies with broad angular coverage will be discussed.

  11. Symmetry witnesses

    Science.gov (United States)

    Aniello, Paolo; Chruściński, Dariusz

    2017-07-01

    A symmetry witness is a suitable subset of the space of selfadjoint trace class operators that allows one to determine whether a linear map is a symmetry transformation, in the sense of Wigner. More precisely, such a set is invariant with respect to an injective densely defined linear operator in the Banach space of selfadjoint trace class operators (if and) only if this operator is a symmetry transformation. According to a linear version of Wigner’s theorem, the set of pure states—the rank-one projections—is a symmetry witness. We show that an analogous result holds for the set of projections with a fixed rank (with some mild constraint on this rank, in the finite-dimensional case). It turns out that this result provides a complete classification of the sets of projections with a fixed rank that are symmetry witnesses. These particular symmetry witnesses are projectable; i.e. reasoning in terms of quantum states, the sets of ‘uniform’ density operators of corresponding fixed rank are symmetry witnesses too.

  12. Variations in the Processing of DNA Double-Strand Breaks Along 60-MeV Therapeutic Proton Beams

    Energy Technology Data Exchange (ETDEWEB)

    Chaudhary, Pankaj; Marshall, Thomas I. [Centre for Cancer Research and Cell Biology, Queen' s University Belfast, Belfast (United Kingdom); Currell, Frederick J. [Centre for Cancer Research and Cell Biology, Queen' s University Belfast, Belfast (United Kingdom); Centre for Plasma Physics, School of Mathematics and Physics, Queen' s University Belfast, Belfast (United Kingdom); Kacperek, Andrzej [Douglas Cyclotron, Clatterbridge Cancer Centre, Bebbington, Wirral (United Kingdom); Schettino, Giuseppe, E-mail: giuseppe.schettino@npl.co.uk [National Physical Laboratory, Teddington (United Kingdom); Prise, Kevin M. [Centre for Cancer Research and Cell Biology, Queen' s University Belfast, Belfast (United Kingdom)

    2016-05-01

    Purpose: To investigate the variations in induction and repair of DNA damage along the proton path, after a previous report on the increasing biological effectiveness along clinically modulated 60-MeV proton beams. Methods and Materials: Human skin fibroblast (AG01522) cells were irradiated along a monoenergetic and a modulated spread-out Bragg peak (SOBP) proton beam used for treating ocular melanoma at the Douglas Cyclotron, Clatterbridge Centre for Oncology, Wirral, Liverpool, United Kingdom. The DNA damage response was studied using the 53BP1 foci formation assay. The linear energy transfer (LET) dependence was studied by irradiating the cells at depths corresponding to entrance, proximal, middle, and distal positions of SOBP and the entrance and peak position for the pristine beam. Results: A significant amount of persistent foci was observed at the distal end of the SOBP, suggesting complex residual DNA double-strand break damage induction corresponding to the highest LET values achievable by modulated proton beams. Unlike the directly irradiated, medium-sharing bystander cells did not show any significant increase in residual foci. Conclusions: The DNA damage response along the proton beam path was similar to the response of X rays, confirming the low-LET quality of the proton exposure. However, at the distal end of SOBP our data indicate an increased complexity of DNA lesions and slower repair kinetics. A lack of significant induction of 53BP1 foci in the bystander cells suggests a minor role of cell signaling for DNA damage under these conditions.

  13. A 1MeV, 1A negative ion accelerator test facility

    International Nuclear Information System (INIS)

    Hanada, M.; Dairaku, M.; Inoue, T.; Miyamoto, K.; Ohara, Y.; Okumura, Y.; Watanabe, K.; Yokoyama, K.

    1995-01-01

    For the Proof-of-Principle test of negative ion acceleration up to 1 MeV, the beam energy required for ITER, a negative ion test facility named MeV Test Facility (MTF) and an ion source/accelerator have been designed and constructed. They are designed to produce a 1 MeV H- beam at a low source pressure of 0.13Pa. The MTF has a power supply system, which constituts of a 1MV, 1A, 60 s Cockcroft-Walton type dc high energy generator and power supplies for negative ion generation and extraction (ion source power supplies). The negative ion source/accelerator is composed of a cesiated volume source and a 5-stage, multi-aperture, electrostatic accelerator. The MTF and the ion source/accelerator have been completed, and the accelertion test up to 1 MeV of the H- ions has started. (orig.)

  14. Comparison of measured with calculated dose distribution from a 120-MeV electron beam from a laser-plasma accelerator

    International Nuclear Information System (INIS)

    Lundh, O.; Rechatin, C.; Faure, J.; Ben-Ismaïl, A.; Lim, J.; De Wagter, C.; De Neve, W.; Malka, V.

    2012-01-01

    Purpose: To evaluate the dose distribution of a 120-MeV laser-plasma accelerated electron beam which may be of potential interest for high-energy electron radiation therapy. Methods: In the interaction between an intense laser pulse and a helium gas jet, a well collimated electron beam with very high energy is produced. A secondary laser beam is used to optically control and to tune the electron beam energy and charge. The potential use of this beam for radiation treatment is evaluated experimentally by measurements of dose deposition in a polystyrene phantom. The results are compared to Monte Carlo simulations using the geant4 code. Results: It has been shown that the laser-plasma accelerated electron beam can deliver a peak dose of more than 1 Gy at the entrance of the phantom in a single laser shot by direct irradiation, without the use of intermediate magnetic transport or focusing. The dose distribution is peaked on axis, with narrow lateral penumbra. Monte Carlo simulations of electron beam propagation and dose deposition indicate that the propagation of the intense electron beam (with large self-fields) can be described by standard models that exclude collective effects in the response of the material. Conclusions: The measurements show that the high-energy electron beams produced by an optically injected laser-plasma accelerator can deliver high enough dose at penetration depths of interest for electron beam radiotherapy of deep-seated tumors. Many engineering issues must be resolved before laser-accelerated electrons can be used for cancer therapy, but they also represent exciting challenges for future research.

  15. Validation of nuclear models in Geant4 using the dose distribution of a 177 MeV proton pencil beam

    International Nuclear Information System (INIS)

    Hall, David C; Paganetti, Harald; Makarova, Anastasia; Gottschalk, Bernard

    2016-01-01

    A proton pencil beam is associated with a surrounding low-dose envelope, originating from nuclear interactions. It is important for treatment planning systems to accurately model this envelope when performing dose calculations for pencil beam scanning treatments, and Monte Carlo (MC) codes are commonly used for this purpose. This work aims to validate the nuclear models employed by the Geant4 MC code, by comparing the simulated absolute dose distribution to a recent experiment of a 177 MeV proton pencil beam stopping in water. Striking agreement is observed over five orders of magnitude, with both the shape and normalisation well modelled. The normalisations of two depth dose curves are lower than experiment, though this could be explained by an experimental positioning error. The Geant4 neutron production model is also verified in the distal region. The entrance dose is poorly modelled, suggesting an unaccounted upstream source of low-energy protons. Recommendations are given for a follow-up experiment which could resolve these issues. (note)

  16. Challenges in designing a very compact 130 MeV Moeller polarimeter for the S-DALINAC

    Energy Technology Data Exchange (ETDEWEB)

    Bahlo, Thore; Enders, Joachim; Kuerzeder, Thorsten; Pietralla, Norbert; Wissmann, Jan [Institut fuer Kernphysik, TU Darmstadt, Darmstadt (Germany)

    2016-07-01

    The Superconducting Darmstadt Linear Accelerator is capable of accelerating polarized electron beams produced by the S-DALINAC Polarized Injector (SPIN). For electron energies of up to 14 MeV it is possible to measure the absolute polarization of the electrons with two Mott polarimeters that are already mounted in the injector beamline. Until now it is not possible to measure the absolute electron beam polarization after the passage of the main accelerator. Therefore a Moeller polarimeter for energies between 50 MeV and 130 MeV is currently being developed. The rather low incident beam energy, the variability of the incident beam energy, and spatial restrictions necessitate a compact set-up with large acceptance. The very restrictive boundary conditions introduce technical and geometrical challenges. We will present the design of the target chamber, of the separation dipole magnet as well as the beam dump.

  17. The operational procedure of an electron beam accelerator

    International Nuclear Information System (INIS)

    Lee, Byung Cheol; Choi, Hwa Lim; Yang, Ki Ho; Han, Young Hwan; Kim, Sung Chan

    2008-12-01

    The KAERI(Korea Atomic Energy of Research Institute) high-power electron beam irradiation facility, operating at the energies between 0.3 MeV and 10 MeV, has provided irradiation services to users in industries, universities, and institute in various fields. This manual is for the operation of an electron beam which is established in KAERI, and describes elementary operation procedures of electron beam between 0.3 Mev and 10 MeV. KAERI Electron Accelerator facility(Daejeon, Korea) consists of two irradiators: one is a low-energy electron beam irradiator operated by normal conducting RF accelerator, the other is medium-energy irradiator operated by superconducting RF accelerator. We explain the check points of prior to operation, operation procedure of this facility and the essential parts of electron beam accelerator

  18. The operational procedure of an electron beam accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Byung Cheol; Choi, Hwa Lim; Yang, Ki Ho; Han, Young Hwan; Kim, Sung Chan

    2008-12-15

    The KAERI(Korea Atomic Energy of Research Institute) high-power electron beam irradiation facility, operating at the energies between 0.3 MeV and 10 MeV, has provided irradiation services to users in industries, universities, and institute in various fields. This manual is for the operation of an electron beam which is established in KAERI, and describes elementary operation procedures of electron beam between 0.3 Mev and 10 MeV. KAERI Electron Accelerator facility(Daejeon, Korea) consists of two irradiators: one is a low-energy electron beam irradiator operated by normal conducting RF accelerator, the other is medium-energy irradiator operated by superconducting RF accelerator. We explain the check points of prior to operation, operation procedure of this facility and the essential parts of electron beam accelerator.

  19. Luminescence properties of pure and doped CaSO4 nanorods irradiated by 15 MeV e-beam

    International Nuclear Information System (INIS)

    Salah, Numan; Alharbi, Najlaa D.; Enani, Mohammad A.

    2014-01-01

    Calcium sulfate (CaSO 4 ) doped with proper activators is a highly sensitive phosphor used in different fields mainly for radiation dosimetry, lighting and display applications. In this work pure and doped nanorods of CaSO 4 were produced by the co-precipitation technique. Samples from this material doped with Ag, Cu, Dy, Eu and Tb were exposed to different doses of 15 MeV e-beam and studied for their thermoluminesence (TL) and photoluminescence (PL) properties. Color center formation leading to PL emissions were investigated before and after e-beam irradiation. The samples doped with rare earths elements (i.e. Dy, Eu and Tb) were observed to have thinner nanorods than the other samples and have higher absorption in the UV region. The Ag and Tb doped samples have poor TL response to e-beam, while those activated by Cu, Dy and Eu have strong glow peaks at around 123 °C. Quite linear response curves in the whole studied exposures i.e. 0.1–100 Gy were also observed in Cu and Dy doped samples. The PL results show that pure CaSO 4 nanorods have active color centers without irradiation, which could be enriched/modified by these impurities mainly rare earths and further enhanced by e-beam irradiation. Eu 3+ → Eu 2+ conversion is clearly observed in Eu doped sample after e-beam irradiation. These results show that these nanorods might be useful in lighting and display devices development

  20. Dose-response relationship for chromosomal aberrations induced in human lymphocytes by 18 MeV electron beam irradiation

    International Nuclear Information System (INIS)

    Lashin, E.A.; Elaasar, E.M.; Moustafa, H.F.; Bakir, Y.Y.; Al Zenki, S.D.

    1990-01-01

    Dose response curves for lymphocyte chromosome aberration frequencies using X- and gamma radiation became an important and reliable indicator as biological dosimeter especially in radiation accidents and occupational over exposures. Nowadays electron beam therapy is frequently used for their advantages in cases of tumours under or near to the body surface. Dose-response curves for these electron beams are rarely published. Human peripheral blood lymphocytes were in vitro irradiated with various low and high doses (0.1 Gy to 4.9 Gy) of 18 MeV electron beams to utilize such a dose-response curve using chromosomal aberration frequencies as a biological indicator. Then we compared the biological curve with physically obtained curves normally used in planning for radiotherapy treatment. It is interesting to find a significant difference between both of them. The biological curve is generally higher in value and the aberrations induced by 93% of a dose is significantly higher and deeper in site than those aberrations induced by the 100% dose calculated physically. If the above observation is confirmed by detailed studies, it would be of importance to the radiotherapist to plan for isodose curves according to biological determinations. (author)

  1. Generation of 300 MeV Quasi-Monochromatic Electron Beams from Laser Wakefield and Initiation of Photonuclear Reactions

    Science.gov (United States)

    Maksimchuk, A.; Beene, J. R.

    2005-10-01

    In the interaction of 30 fs, 40 TW Ti:sapphire Hercules laser at the University of Michigan, which is focused to the intensity of 10^19 W/cm^2 onto a supersonic He gas jet with electron density close to the resonant density, we observed quasi-monoenergetic electron beams with energy up to 300 MeV and angular divergence of about 10 mrad. The results on characterization of relativistic electron beam in terms of energy spread, its charge, divergence and pointing stability will be presented. 2D PIC simulations performed for the parameters close to the experimental conditions show the evolution of the laser pulse in plasma, electron injection, and the specifics of electron acceleration observed in experiments. Resulted relativistic electron beams have been used to perform gamma-neutron activation of ^12C and ^63Cu and photo-fission of ^238U. We demonstrated that approximately 10^6 reaction per shot has been produced in each case. This work was supported by the NSF through the Physics Frontier Center FOCUS. JRB, DRS, DWS, and CRV acknowledge support by the DOE under contract DE-AC05-00OR22725 with UT-Battelle, LLC.

  2. Enacting laws concerning radiation safety management for students using X-rays and electron beams under 1 MeV

    International Nuclear Information System (INIS)

    Nishizawa, Kunihide; Shibata, Michihiro; Saze, Takuya

    2004-01-01

    Laws concerning radiation safety management were analyzed from the point of view of defining precisely what is meant by radiation and what is meant by the subject. There are no laws to protect students from radiation hazards when using X-rays and electron beams under 1 MeV for research and/or education. The Law concerning Technical Standards for Preventing Radiation Hazards gives the authorities the power to enact new rules and regulations that will protect the students. The Radiation Council must take charge for enactment of all laws regarding radiation safety management. (author)

  3. Experimental determination of beam quality factors, kQ, for two types of Farmer chamber in a 10 MV photon and a 175 MeV proton beam.

    Science.gov (United States)

    Medin, Joakim; Ross, Carl K; Klassen, Norman V; Palmans, Hugo; Grusell, Erik; Grindborg, Jan-Erik

    2006-03-21

    Absorbed doses determined with a sealed water calorimeter operated at 4 degrees C are compared with the results obtained using ionization chambers and the IAEA TRS-398 code of practice in a 10 MV photon beam (TPR(20,10) = 0.734) and a 175 MeV proton beam (at a depth corresponding to the residual range, R(res) = 14.7 cm). Three NE 2571 and two FC65-G ionization chambers were calibrated in terms of absorbed-dose-to-water in (60)Co at the Swedish secondary standard dosimetry laboratory, directly traceable to the BIPM. In the photon beam quality, calorimetry was found to agree with ionometry within 0.3%, confirming the k(Q) values tabulated in TRS-398. In contrast, a 1.8% deviation was found in the proton beam at 6 g cm(-2) depth, suggesting that the TRS-398 tabulated k(Q) values for these two ionization chamber types are too high. Assuming no perturbation effect in the proton beam for the ionization chambers, a value for (w(air)/e)(Q) of 33.6 J C(-1) +/- 1.7% (k = 1) can be derived from these measurements. An analytical evaluation of the effect from non-elastic nuclear interactions in the ionization chamber wall indicates a perturbation effect of 0.6%. Including this estimated result in the proton beam would increase the determined (w(air)/e)(Q) value by the same amount.

  4. Modifications in the structural and optical properties of nanocrystalline CaWO4 induced by 8 MeV electron beam irradiation

    International Nuclear Information System (INIS)

    Aloysius Sabu, N.; Priyanka, K.P.; Ganesh, Sanjeev; Varghese, Thomas

    2016-01-01

    In this article we report the post irradiation effects in the structural and optical properties of nanocrystalline calcium tungstate synthesized by chemical precipitation and heat treatment. The samples were subjected to different doses of high-energy electron beam obtained from an 8 MeV Microton. Investigations using X-ray diffraction, scanning electron microscopy and Raman spectra confirmed changes in particle size and structural parameters. However, no phase change was detected for irradiated samples. The stretching/compressive strain caused by high energy electrons is responsible for the slight shift in the XRD peaks of irradiated samples. Modifications in the morphology of different samples were confirmed by scanning electron microscopy. Ultraviolet-visible absorption studies showed variations in the optical band gap (4.08–4.25 eV) upon electron-beam irradiation. New photoluminescence behaviour in electron beam irradiated nanocrystalline CaWO 4 was evidenced. A blue shift of the PL peak with increase in intensity was observed in all the irradiated samples. - Highlights: • Calcium tungstate nanocrystals are synthesized by simple chemical precipitation method. • Electron beam induced modifications in the structural and optical properties are investigated. • New photoluminescence behaviour is evidenced due to beam irradiation.

  5. Comparison of measured with calculated dose distribution from a 120-MeV electron beam from a laser-plasma accelerator.

    Science.gov (United States)

    Lundh, O; Rechatin, C; Faure, J; Ben-Ismaïl, A; Lim, J; De Wagter, C; De Neve, W; Malka, V

    2012-06-01

    To evaluate the dose distribution of a 120-MeV laser-plasma accelerated electron beam which may be of potential interest for high-energy electron radiation therapy. In the interaction between an intense laser pulse and a helium gas jet, a well collimated electron beam with very high energy is produced. A secondary laser beam is used to optically control and to tune the electron beam energy and charge. The potential use of this beam for radiation treatment is evaluated experimentally by measurements of dose deposition in a polystyrene phantom. The results are compared to Monte Carlo simulations using the geant4 code. It has been shown that the laser-plasma accelerated electron beam can deliver a peak dose of more than 1 Gy at the entrance of the phantom in a single laser shot by direct irradiation, without the use of intermediate magnetic transport or focusing. The dose distribution is peaked on axis, with narrow lateral penumbra. Monte Carlo simulations of electron beam propagation and dose deposition indicate that the propagation of the intense electron beam (with large self-fields) can be described by standard models that exclude collective effects in the response of the material. The measurements show that the high-energy electron beams produced by an optically injected laser-plasma accelerator can deliver high enough dose at penetration depths of interest for electron beam radiotherapy of deep-seated tumors. Many engineering issues must be resolved before laser-accelerated electrons can be used for cancer therapy, but they also represent exciting challenges for future research. © 2012 American Association of Physicists in Medicine.

  6. Conceptual design of 30 MeV magnet system used for BNCT epithermal neutron source

    International Nuclear Information System (INIS)

    Slamet Santosa; Taufik

    2015-01-01

    Conceptual design of 30 MeV Magnet System Used for BNCT Epithermal Neutron Source has been done based on methods of empirical model of basic equation, experiences of 13 MeV cyclotron magnet design and personal communications. In the field of health, cyclotron can be used as an epithermal neutron source for Boron Neutron Capture Therapy (BNCT). The development of cyclotron producing epithermal neutrons for BNCT has been performed at Kyoto University, of which it produces a proton beam current of 1.1 mA with energy of 30 MeV. With some experiences on 13 MeV cyclotron magnet design, to support BNCT research and development we performed the design studies of 30 MeV cyclotron magnet system, which is one of the main components of the cyclotron for deflecting proton beam into circular trajectory and serves as beam focusing. Results of this study are expected to define the parameters of particular cyclotron magnet. The scope of this study includes the study of the parameters component of the 30 MeV cyclotron and magnet initial parameters. The empirical method of basic equation model is then corroborated by a simulation using Superfish software. Based on the results, a 30 MeV cyclotron magnet for BNCT neutron source enables to be realized with the parameters of B 0 = 1.06 T, frequency RF = 64.733938 ≈ 65 MHz, the external radius of 0.73 m, the radius of the polar = 0.85 m, BH = 1.95 T and a gap hill of 4 cm. Because proton beam current that be needed for BNCT application is very large, then in the calculation it is chosen a great focusing axial νz = 0.630361 which can generate B V = 0.44 T. (author)

  7. Photoneutron intensity variation with field size around radiotherapy linear accelerator 18-MeV X-ray beam

    Energy Technology Data Exchange (ETDEWEB)

    Al-Ghamdi, H.; Fazal-ur-Rehman [Physics Department, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia); Al-Jarallah, M.I. [Physics Department, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia)], E-mail: mibrahim@kfupm.edu.sa; Maalej, N. [Physics Department, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia)

    2008-08-15

    In X-ray radiotherapy accelerators, neutrons are produced mainly by ({gamma},n) reaction when high energy X-rays interact with high Z materials of the linear accelerator head. These materials include the lead (Pb) used as shielding in the collimator, tungsten (W) target used for the production of X-rays and iron (Fe) in the accelerator head. These unwanted neutrons contaminate the therapeutic beam and contribute to the patient dose during the treatment of a cancer patient. Knowing the neutron distribution around the radiotherapy accelerator is therefore desired. CR-39 nuclear track detectors (NTDs) were used to study the variation of fast and thermal neutron relative intensities around an 18 MeV linear accelerator X-ray beam with the field sizes of 0, 10x10, 20x20, 30x30 and 40x40cm{sup 2}. For fast neutron detection, bare NTDs were used. For thermal neutron detection, NTDs were covered with lithium tetra borate (Li{sub 2}B{sub 4}O{sub 7}) converters. The NTDs were placed at different locations in the direction perpendicular to the treatment couch (transversal) and in the direction parallel to the treatment couch (longitudinal) with respect to the isocenter of the accelerator. The fast neutron relative intensity is symmetrical about the beam axis and exhibits an exponential-like drop with distance from the isocenter of the accelerator for all the field sizes. At the primary beam (isocenter), the relative fast neutron intensity is highest for 40x40cm{sup 2} field size and decreases linearly with the decrease in the field size. However, fast neutron intensities do not change significantly with beam size for the measurements outside the primary beam. The fast neutron intensity in the longitudinal direction outside the primary beam decreases linearly with the field size. The thermal neutron intensity, at any location, was found to be almost independent of the field size.

  8. Effect of 1MeV electron beam on transistors and circuits

    International Nuclear Information System (INIS)

    Lee, Tae Hoon

    1998-02-01

    It has been known that semiconductor devices operating in a radiation environment exhibited significant alterations of their electrical responses. Since an electron beam bombardment produces lattice damage in Si and charged defects in SiO 2 , several electrical parameters of transistors exhibit significant changes. Those parameters are the current gain of BJT (Bipolar Junction Transistor) and the threshold voltage of MOSFET (Metal Oxide Semiconductor Field Effect Transistor). The degradation of transistors brings about that of circuits. This paper presents the results of experiments and simulations performed to study the effects of 1MeV electron beam irradiation on selected silicon transistors and circuits. For BJTs, the current gains of npn (2N3904) and pnp (2N3906) linearly decreased as the irradiation dose increased, and from this result, the damage constants, Ks were obtained as 13.65 for 2N3904 and 22.52 for 2N3906 in MGy, indicating a more stable operation in the electron radiation environment for pnp than that for npn. The decrease of current gain was due to that of minority-carrier lifetime in the base region. For MOSFETs (CD4007s), the threshold voltages of NMOS and PMOS shifted to the lower values, which was resulted from the accumulation of charge in SiO 2 . The charges could be categorized into fixed oxide charge and interfacial trap charge. From experimental results, the amounts of the induced charges could be quantitatively estimated. These degradations of transistors brought about the decrease in the voltage gain of CE (Common Emitter) amplifier and the shifts in the inverting voltage of inverter. Additionally, PSpice simulations of these circuits were carried out by modeling of irradiated transistors. The comparison of simulation with experiment showed the relatively good agreement of simulation for the degradation of circuits after irradiation

  9. A P + DEUTERON PROTON POLARIMETER AT 200 MEV.

    Energy Technology Data Exchange (ETDEWEB)

    HUANG,H.; ROSER,T.; ZELENSKI,A.; KURITA,K.; STEPHENSON,E.; TOOLE,R.

    2002-06-02

    There has been concern about the analyzing power of the p-Carbon polarimeter at the end of 200 MeV LINAC of BNL. A new polarimeter based on proton-deuteron scattering was installed and we have repeated the calibration of proton-Carbon scattering at 12 degrees and 200 MeV against proton-deuteron scattering. The result is consistent with the value of A=0.62 now used to measure the beam polarization at the end of the LINAC.

  10. Shielding calculations for industrial 5/7.5MeV electron accelerators using the MCNP Monte Carlo Code

    Science.gov (United States)

    Peri, Eyal; Orion, Itzhak

    2017-09-01

    High energy X-rays from accelerators are used to irradiate food ingredients to prevent growth and development of unwanted biological organisms in food, and by that extend the shelf life of the products. The production of X-rays is done by accelerating 5 MeV electrons and bombarding them into a heavy target (high Z). Since 2004, the FDA has approved using 7.5 MeV energy, providing higher production rates with lower treatments costs. In this study we calculated all the essential data needed for a straightforward concrete shielding design of typical food accelerator rooms. The following evaluation is done using the MCNP Monte Carlo code system: (1) Angular dependence (0-180°) of photon dose rate for 5 MeV and 7.5 MeV electron beams bombarding iron, aluminum, gold, tantalum, and tungsten targets. (2) Angular dependence (0-180°) spectral distribution simulations of bremsstrahlung for gold, tantalum, and tungsten bombarded by 5 MeV and 7.5 MeV electron beams. (3) Concrete attenuation calculations in several photon emission angles for the 5 MeV and 7.5 MeV electron beams bombarding a tantalum target. Based on the simulation, we calculated the expected increase in dose rate for facilities intending to increase the energy from 5 MeV to 7.5 MeV, and the concrete width needed to be added in order to keep the existing dose rate unchanged.

  11. Thermoluminescence properties of Al2O3:Tb nanoparticles irradiated by gamma rays and 85 MeV C6+ ion beam

    International Nuclear Information System (INIS)

    Salah, Numan; Alharbi, Najlaa D.; Habib, Sami S.; Lochab, S.P.

    2015-01-01

    Carbon ions beam is recently recognized as an ideal cancer treatment modality, because of its excellent local tumor control. These ions have a high relative biological effectiveness resulting from high linear energy transfer (LET) and their sharp Bragg peak. However, the dose of those energetic ions needs to be measured with great precision using a proper dosimeter. Aluminum Oxide (Al 2 O 3 ) is a highly luminescent phosphor widely used for radiation dosimetry using thermoluminesence (TL) technique. In this work nanoparticles of this material activated by different elements like Eu, Tb, Dy, Cu and Ag were evaluated for their TL response to gamma rays irradiation. Tb doped sample is found to be the most sensitive sample, which could be selected for exposure to 85 MeV C 6+ ion beam in the fluence range 10 9 –10 13 ions/cm 2 . The obtained result shows that C ion beam irradiated sample has a simple glow curve structure with a prominent glow peak at around 230 °C. This glow curve has a dosimetric peak better than those induced by gamma rays. This glow peak exhibits a linear response in the range 10 9 –10 11 ions/cm 2 , corresponding to the equivalent absorbed doses 0.285–28.5 kGy. The absorbed doses, penetration depths and main energy loss were calculated using TRIM code based on the Monte Carlo simulation. The wide linear response of Al 2 O 3 :Tb nanoparticles along with the low fading makes this low cost nanomaterial a good candidate for C ion beam dosimetry. - Highlights: • Nanoparticles of Al 2 O 3 doped with Eu, Tb, Dy, Cu and Ag were synthesised. • They were evaluated for their TL response to gamma rays and C ion beam irradiation. • Tb doped sample is the most sensitive sample to gamma rays. • Al 2 O 3 :Tb was exposed to 85 MeV C 6+ ion beam in the fluence range 10 9 -10 13 ions/cm 2 . • The glow peak induced by C ions has a linear response in the range 10 9 -10 11 ions/cm 2

  12. Plasma production for the 50 MeV plasma lens experiment at LBL

    International Nuclear Information System (INIS)

    Leemans, W.; van der Geer, B.; de Loos, M.; Conde, M.; Govil, R.; Chattopadhyay, S.

    1994-06-01

    The Center for Beam Physics at LBL has constructed a Beam Test Facility (BTF) housing a 50 MeV electron beam transport line, which uses the linac injector from the Advanced Light Source, and a terawatt Ti:Al 2 O 3 laser system. The linac operates at 50 MeV and generates 15 ps long electron bunches containing a charge of up to 2 nC. The measured unnormalized beam emittance is 0.33 mm-mrad. These parameters allow for a comprehensive study of focusing of relativistic electron beams with plasma columns, in both the overdense and underdense regime (adiabatic and tapered lenses). A study of adiabatic and/or tapered lenses requires careful control of plasma density and scale lengths of the plasma. We present experimental results on the production of plasmas through resonant two-photon ionization, with parameters relevant to an upcoming plasma lens experiment

  13. Eta meson photoproduction on hydrogen from threshold up to 1100 MeV: Measurement of the {Sigma} beam asymmetry; Photoproduction du meson eta sur l`hydrogene du seuil jusqu`a 1100 MeV: Mesure de l`asymetrie faisceau {Sigma}

    Energy Technology Data Exchange (ETDEWEB)

    Ajaka, Jassem [Inst. de Physique Nucleaire, Paris-11 Univ., 91 - Orsay (France)

    1997-12-12

    The photoproduction of {eta} meson on hydrogen has been measured from threshold to 1100 MeV in GRAAL experiment performed in 1996 - 1997 at the ESRF in Grenoble by a collaboration of Italian, French and Russian groups. A tagged and linearly polarized photon beam has been produced by back-scattering a laser beam on the 6 GeV electron beam of the ESRF ring. The target was a liquid hydrogen target of 3 cm. A 4{pi} detection system was used. It is composed of three layers of detectors: wire chambers, scintillator counters and calorimeters. We had in charge to install and calibrate a double wall of scintillator bars (3 x 3 m) designed to detect at forward angles (1 deg. - 25 deg.) the charged particles and to measure their loss of energy and their time of flight. We analyzed the results of the reaction {gamma}p {yields} {eta}p by identifying the {eta} in the lateral calorimeter which is a BGO ball and by detecting the proton in the scintillation counters. The {Sigma} beam asymmetry was extracted from {phi} distribution of {eta} meson and was plotted against {theta}{sub CM} of {eta} for 6 intervals of energy between the threshold and 1100 MeV. The interpretation of {Sigma} beam asymmetry was performed in the frame of the isobaric model. The use of two resonances S11(1535) and D13(1520) to explain our results was not sufficient. We had to take into account in addition the excitation of the resonances P13(1720), D15(1675) and P13(1880). The last being missing in the table of resonances and recently revealed by quark models. (author) 94 refs., 56 figs., 20 tabs.

  14. Evolving and Combining Facial Composites: Between-Witness and Within-Witness Morphs Compared

    Science.gov (United States)

    Valentine, Tim; Davis, Josh P.; Thorner, Kate; Solomon, Chris; Gibson, Stuart

    2010-01-01

    Student participant-witnesses produced 4 composites of unfamiliar faces with a system that uses a genetic algorithm to evolve appearance of artificial faces. Morphs of 4 composites produced by different witnesses (between-witness morphs) were judged better likenesses (Experiment 1) and were more frequently named (Experiment 2) by participants who…

  15. 160 MeV $H^-$ Injection into the CERN PSB

    CERN Document Server

    Weterings, W; Borburgh, J; Fowler, T; Gerigk, F; Goddard, B; Hanke, K; Martini, M; Sermeus, L

    2007-01-01

    The H- beam from the proposed LINAC4 will be injected into the four existing rings of the PS Booster at 160 MeV. A substantial upgrade of the injection region is required, including the modification of the beam distribution system and the construction of a new H- injection system. This paper discusses beam dynamics and hardware requirements and presents the results of optimisation studies of the injection process for different beam characteristics and scenarios. The resulting conceptual design of the injection region is presented, together with the main hardware modifications and performance specifications.

  16. Determining the stereochemical structures of molecular ions by ''Coulomb-explosion'' techniques with fast (MeV) molecular ion beams

    International Nuclear Information System (INIS)

    Gemmell, D.S.

    1980-01-01

    Recent studies on the dissociation of fast (MeV) molecular ion beams in thin foils suggest a novel alternative approach to the determination of molecular ion structures. In this article we review some recent high-resolution studies on the interactions of fast molecular ion beams with solid and gaseous targets and indicate how such studies may be applied to the problem of determining molecular ion structures. The main features of the Coulomb explosion of fast-moving molecular ion projectiles and the manner in which Coulomb-explosion techniques may be applied to the problem (difficult to attack by more conventional means) of determining the stereochemical structures of molecular ions has been described in this paper. Examples have been given of early experiments designed to elicit structure information. The techniques are still in their infancy, and it is to be expected that as both the technology and the analysis are refined, the method will make valuable contributions to the determination of molecular ion structures

  17. A simple and powerful XY-Type current monitor for 30 MeV IPEN/CNEN-SP cyclotron

    Energy Technology Data Exchange (ETDEWEB)

    Barcellos, Henrique; Matsuda, Hylton; Sumyia, Luiz Carlos do A.; Junqueira, Fernando de C.; Costa, Osvaldo L. da, E-mail: hbolivei@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2017-11-01

    A water-cooled XY-type current monitor was designed and built in the Cyclotrons Laboratory of the Nuclear and Energy Research Institute (IPEN). It is a very simple design and easily adaptable to the cyclotron beam lines. Tests were done demonstrating to be an instrument of great assistance in proton beam position along beam transport line and target port. Nowadays the XY-type current monitor has been widely used in {sup 18}F-FDG routine productions, employing irradiation system which were originally designed for productions on 18 MeV cyclotron accelerator only, however, applying the XY-type current monitor the target port may be exchanged between the 30 MeV and 18 MeV cyclotrons and the observed results are in perfect agreement with expected. (author)

  18. 8 MeV electron beam induced modifications in the thermal, structural and electrical properties of nanophase CeO2 for potential electronics applications

    Science.gov (United States)

    Babitha, K. K.; Sreedevi, A.; Priyanka, K. P.; Ganesh, S.; Varghese, Thomas

    2018-06-01

    The effect of 8 MeV electron beam irradiation on the thermal, structural and electrical properties of CeO2 nanoparticles synthesized by chemical precipitation route was investigated. The dose dependent effect of electron irradiation was studied using various characterization techniques such as, thermogravimetric and differential thermal analyses, X-ray diffraction, Fourier transformed infrared spectroscopy and impedance spectroscopy. Systematic investigation based on the results of structural studies confirm that electron beam irradiation induces defects and particle size variation on CeO2 nanoparticles, which in turn results improvements in AC conductivity, dielectric constant and loss tangent. Structural modifications and high value of dielectric constant for CeO2 nanoparticles due to electron beam irradiation make it as a promising material for the fabrication of gate dielectric in metal oxide semiconductor devices.

  19. External proton and Li beams

    International Nuclear Information System (INIS)

    Schuff, Juan A.; Burlon, Alejandro A.; Debray, Mario E.; Kesque, Jose M.; Kreiner, Andres J.; Stoliar, Pablo A.; Naab, Fabian; Ozafran, Mabel J.; Vazquez, Monica E.; Perez de la Hoz, A.; Somacal, Hector; Valda, Alejandro; Canevas, S.; Ruffolo, M.; Tasat, D.R.; Muhlmann, M. C.

    2000-01-01

    In the frame of a feasibility study to introduce proton therapy in Argentina in a collaborative agreement between the Physics and Radiobiology Departments of the National Atomic Energy Commission or Argentina and the Centre de Protontherapie de Orsay, France, external proton and Li beams were produced at the TANDAR accelerator in Buenos Aires. The specific aim of this work was to start radiobiology studies on cell cultures and small laboratory animals. In particular we seek to determine here the relative biological effectiveness, RBE, for proton and Li beams as a function of energy for different tumor and normal cell lines. The 24 MeV proton beam was diffused using a 25 μm gold foil and extracted through a Kapton window to obtain a homogeneous field (constant to 95%) of about 7 cm in diameter. Measurements were carried out with quasi-monoenergetic beams (of 20.2 ± 0.07 MeV, 2.9 ± 0.10 MeV y 1.5 ± 0.1 MeV for protons and 21.4 ± 0.4 MeV for Lithium). Proton fluence and Bragg peaks were measured. The dose delivered in each case was monitored on-line with a calibrated transmission ionization chamber. Three cell lines PDV, PDVC 57 and V 79 (as a reference) were irradiated with γ-rays, proton and lithium beams with linear energy transfer (LET) from 2 to 100 keV/μm. RBE values in the range of 1.2-5.9 were obtained. In addition preliminary studies on chromosomal aberrations and viability of alveolar macrophages were carried out. (author)

  20. Minimal tomography with entanglement witnesses

    International Nuclear Information System (INIS)

    Zhu Huangjun; Teo Yong Siah; Englert, Berthold-Georg

    2010-01-01

    We introduce informationally complete measurements whose outcomes are entanglement witnesses and so answer the question of how many witnesses need to be measured to decide whether an arbitrary state is entangled or not: as many as the dimension of the state space. The witnesses can be measured successively; if all of them give an inconclusive result, one exploits their tomographic completeness for a reconstruction of the quantum state and can then determine its entanglement properties by data processing. There are witnesses that are optimal for this purpose. The optimized witness-based measurement can provide exponential improvement with respect to witness efficiency in high-dimensional Hilbert spaces, at the price of a reduction in the tomographic efficiency. We describe a systematic construction and illustrate the matter with the example of two qubits. For the case of two polarization qubits of photons, we show how existing technology can be used to implement the optimized witnesses in a very efficient way. Owing to the details of the implementation, which actually measures the eigenstate basis of the witness rather than solely determining the expectation value of the witness, one does not need to measure more than six witnesses in this example of a 16-dimensional state space.

  1. Minimal tomography with entanglement witnesses

    Science.gov (United States)

    Zhu, Huangjun; Teo, Yong Siah; Englert, Berthold-Georg

    2010-05-01

    We introduce informationally complete measurements whose outcomes are entanglement witnesses and so answer the question of how many witnesses need to be measured to decide whether an arbitrary state is entangled or not: as many as the dimension of the state space. The witnesses can be measured successively; if all of them give an inconclusive result, one exploits their tomographic completeness for a reconstruction of the quantum state and can then determine its entanglement properties by data processing. There are witnesses that are optimal for this purpose. The optimized witness-based measurement can provide exponential improvement with respect to witness efficiency in high-dimensional Hilbert spaces, at the price of a reduction in the tomographic efficiency. We describe a systematic construction and illustrate the matter with the example of two qubits. For the case of two polarization qubits of photons, we show how existing technology can be used to implement the optimized witnesses in a very efficient way. Owing to the details of the implementation, which actually measures the eigenstate basis of the witness rather than solely determining the expectation value of the witness, one does not need to measure more than six witnesses in this example of a 16-dimensional state space.

  2. Andromede project: Surface analysis and modification with probes from hydrogen to nano-particles in the MeV energy range

    International Nuclear Information System (INIS)

    Eller, Michael J.; Cottereau, Evelyne; Rasser, Bernard; Verzeroli, Elodie; Agnus, Benoit; Gaubert, Gabriel; Donzel, Xavier; Delobbe, Anne; Della-Negra, Serge

    2015-01-01

    The Andromede project is the center of a multi-disciplinary team which will build a new instrument for surface modification and analysis using the impact of probes from hydrogen to nano-particles (Au 400 +4 ) in the MeV range. For this new instrument a series of atomic, polyatomic, molecular and nano-particle ion beams will be delivered using two ion sources in tandem, a liquid metal ion source and an electron cyclotron resonance source. The delivered ion beams will be accelerated to high energy with a 4 MeV van de Graaff type accelerator. By using a suite of probes in the MeV energy range, ion beam analysis techniques, MeV atomic and cluster secondary ion mass spectrometry can all be performed in one location. A key feature of the instrument is its ability to produce an intense beam for injection into the accelerator. The commissioning of the two sources shows that intense beams from atomic ions to nano-particles can be delivered for subsequent acceleration. The calculations and measurements for the two sources are presented.

  3. Optimum design for 12 MeV linear induction accelerator diode

    International Nuclear Information System (INIS)

    Yu Haijun; Shi Jinshui; Li Qin; He Guorong; Ma Bing; Wang Jingsheng; Wang Liping

    2001-01-01

    A series of optimization designs of electron diode in 12 Mev linear induction accelerator are studied by using numerical simulation code MAGIC and experiment method in order to improve the electron beam quality. MAGIC code solves the Maxwell equations in the presence of charged particle, electron field distribution on cathode surface which influences electron emission is given, the optimum diode is obtained by comparing the results of experiment in 12 MeV linear induction accelerator. The author also gives SEM analysis and experiment comparison of velvet emission. Finally, emitted current I e = 8.52 kA, beam current I 8 ≥ 3.0 kA, targeted current I 0 ≥ 2.30 kA with optimum diode are obtained

  4. Measurement of the neutron fields produced by a 62 MeV proton beam on a PMMA phantom using extended range Bonner sphere spectrometers

    Energy Technology Data Exchange (ETDEWEB)

    Amgarou, K. [Grup de Recerca en Radiacions Ionitzants, Departament de Fisica, Universitat Autonoma de Barcelona, E-08193 Bellaterra (Spain); Bedogni, R., E-mail: roberto.bedogni@lnf.infn.it [INFN-Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali di Frascati, Via E. Fermi n. 40, 00044 Frascati (Italy); Domingo, C. [Grup de Recerca en Radiacions Ionitzants, Departament de Fisica, Universitat Autonoma de Barcelona, E-08193 Bellaterra (Spain); Esposito, A.; Gentile, A.; Carinci, G. [INFN-Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali di Frascati, Via E. Fermi n. 40, 00044 Frascati (Italy); Russo, S. [INFN-Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali del Sud, via S. Sofia 44, 95123 Catania (Italy)

    2011-10-21

    The experimental characterization of the neutron fields produced as parasitic effect in medical accelerators is assuming an increased importance for either the patient protection or the facility design aspects. Medical accelerators are diverse in terms of particle type (electrons or hadrons) and energy, but the radiation fields around them have in common (provided that a given threshold energy is reached) the presence of neutrons with energy span over several orders of magnitude. Due to the large variability of neutron energy, field or dosimetry measurements in these workplaces are very complex, and in general, cannot be performed with ready-to-use commercial instruments. In spite of its poor energy resolution, the Bonner Sphere Spectrometer (BSS) is the only instrument able to simultaneously determine all spectral components in such workplaces. The energy range of this instrument is limited to E<20 MeV if only polyethylene spheres are used, but can be extended to hundreds of MeV by including metal-loaded spheres (extended range BSS, indicated with ERBSS). With the aim of providing useful data to the scientific community involved in neutron measurements at hadron therapy facilities, an ERBSS experiment was carried out at the Centro di AdroTerapia e Applicazioni Nucleari Avanzate (CATANA) of INFN-LNS (Laboratori Nazionali del Sud), where a proton beam routinely used for ophthalmic cancer treatments is available. The 62 MeV beam was directed towards a PMMA phantom, simulating the patient, and two neutron measurement points were established at 0{sup o} and 90{sup o} with respect to the beam-line. Here the ERBSS of UAB (Universidad Autonoma de Barcelona-Grup de Fisica de les Radiacions) and INFN (Istituto Nazionale di Fisica Nucleare-Laboratori Nazionali di Frascati) were exposed to characterize the 'forward' and 'sideward' proton-induced neutron fields. The use of two ERBSS characterized by different set of spheres, central detectors, and

  5. HOM (higher-order mode) test of the storage ring single-cell cavity with a 20-MeV e- beam for the Advanced Photon Source (APS)

    International Nuclear Information System (INIS)

    Song, J.; Kang, Y.W.; Kustom, R.

    1993-01-01

    To test the effectiveness of damping techniques of the APS storage ring single-cell cavity, a beamline has been designed and assembled to use the ANL Chemistry Division linac beam (20-MeV, FWHM of 20 ps). A single-cell cavity will be excited by the electron beam to investigate the effect on higher-order modes (HOMs) with and without coaxial dampers (H-loop damper, E-probe damper), and wideband aperture dampers. In order for the beam to propagate on- and off-center of the cavity, the beamline consists of two sections -- a beam collimating section and a cavity measurement section -- separated by two double Aluminum foil windows. RF cavity measurements were made with coupling loops and E-probes. The results are compared with both the TBCI calculations and 'cold' measurements with the bead-perturbation method. The data acquisition system and beam diagnostics will be described in a separate paper

  6. Non-Linear Beam Transport System for the LENS 7 MeV Proton Beam

    CERN Document Server

    Jones, William P; Derenchuk, Vladimir Peter; Rinckel, Thomas; Solberg, Keith

    2005-01-01

    A beam transport system has been designed to carry a high-intensity low-emittance proton beam from the exit of the RFQ-DTL acceleration system of the Indiana University Low Energy Neutron System (LENS)* to the neutron production target. The goal of the design was to provide a beam of uniform density over a 3cm by 3cm area at the target. Two octupole magnets** are employed in the beam line to provide the necessary beam phase space manipulations to achieve this goal. First order calculations were done using TRANSPORT and second order calculations have been performed using TURTLE. Second order simulations have been done using both a Gaussian beam distribution and a particle set generated by calculations of beam transport through the RFQ-DTL using PARMILA. Comparison of the design characteristics with initial measurements from the LENS commissioning process will be made.

  7. Cross section ratio and angular distributions of the reaction p + d → 3He + η at 48.8 MeV and 59.8 MeV excess energy

    International Nuclear Information System (INIS)

    Adlarson, P.; Calen, H.; Fransson, K.; Gullstroem, C.O.; Heijkenskjoeld, L.; Hoeistad, B.; Johansson, T.; Marciniewski, P.; Redmer, C.F.; Wolke, M.; Zlomanczuk, J.; Augustyniak, W.; Marianski, B.; Morsch, H.P.; Trzcinski, A.; Zupranski, P.; Bardan, W.; Ciepal, I.; Czerwinski, E.; Hodana, M.; Jany, A.; Jany, B.R.; Jarczyk, L.; Kamys, B.; Kistryn, S.; Krzemien, W.; Magiera, A.; Moskal, P.; Ozerianska, I.; Podkopal, P.; Rudy, Z.; Skurzok, M.; Smyrski, J.; Wronska, A.; Zielinski, M.J.; Bashkanov, M.; Clement, H.; Doroshkevich, E.; Perez del Rio, E.; Pricking, A.; Skorodko, T.; Wagner, G.J.; Bergmann, F.S.; Demmich, K.; Goslawski, P.; Huesken, N.; Khoukaz, A.; Passfeld, A.; Taeschner, A.; Berlowski, M.; Stepaniak, J.; Bhatt, H.; Lalwani, K.; Varma, R.; Buescher, M.; Engels, R.; Goldenbaum, F.; Hejny, V.; Khan, F.A.; Lersch, D.; Lorentz, B.; Maier, R.; Ohm, H.; Prasuhn, D.; Schadmand, S.; Sefzick, T.; Stassen, R.; Sterzenbach, G.; Stockhorst, H.; Stroeher, H.; Wurm, P.; Zurek, M.; Coderre, D.; Ritman, J.; Erven, A.; Erven, W.; Kemmerling, G.; Kleines, H.; Wuestner, P.; Eyrich, W.; Hauenstein, F.; Krapp, M.; Zink, A.; Fedorets, P.; Foehl, K.; Goswami, A.; Grigoryev, K.; Kirillov, D.A.; Piskunov, N.M.; Klos, B.; Stephan, E.; Weglorz, W.; Kulessa, P.; Pysz, K.; Siudak, R.; Szczurek, A.; Kupsc, A.; Pszczel, D.; Mikirtychiants, M.; Pyszniak, A.; Roy, A.; Sawant, S.; Serdyuk, V.; Sopov, V.; Yamamoto, A.; Yurev, L.; Zabierowski, J.

    2014-01-01

    We present new data for angular distributions and on the cross section ratio of the p+d → 3 He + η reaction at excess energies of Q = 48.8 MeV and Q = 59.8 MeV. The data have been obtained at the WASA-at-COSY experiment (Forschungszentrum Juelich) using a proton beam and a deuterium pellet target. While the shape of obtained angular distributions show only a slow variation with the energy, the new results indicate a distinct and unexpected total cross section fluctuation between Q = 20 MeV and Q = 60 MeV, which might indicate the variation of the production mechanism within this energy interval. (orig.)

  8. Luminescence properties of pure and doped CaSO{sub 4} nanorods irradiated by 15 MeV e-beam

    Energy Technology Data Exchange (ETDEWEB)

    Salah, Numan, E-mail: nsalah@kau.edu.sa [Center of Nanotechnology, King Abdulaziz University, Jeddah 21589 (Saudi Arabia); Alharbi, Najlaa D. [Sciences Faculty for Girls, King Abdulaziz University, Jeddah 21589 (Saudi Arabia); Enani, Mohammad A. [Dept. of Nuclear Engineering, Faculty of Engineering, King Abdulaziz University, Jeddah 21589 (Saudi Arabia)

    2014-01-15

    Calcium sulfate (CaSO{sub 4}) doped with proper activators is a highly sensitive phosphor used in different fields mainly for radiation dosimetry, lighting and display applications. In this work pure and doped nanorods of CaSO{sub 4} were produced by the co-precipitation technique. Samples from this material doped with Ag, Cu, Dy, Eu and Tb were exposed to different doses of 15 MeV e-beam and studied for their thermoluminesence (TL) and photoluminescence (PL) properties. Color center formation leading to PL emissions were investigated before and after e-beam irradiation. The samples doped with rare earths elements (i.e. Dy, Eu and Tb) were observed to have thinner nanorods than the other samples and have higher absorption in the UV region. The Ag and Tb doped samples have poor TL response to e-beam, while those activated by Cu, Dy and Eu have strong glow peaks at around 123 °C. Quite linear response curves in the whole studied exposures i.e. 0.1–100 Gy were also observed in Cu and Dy doped samples. The PL results show that pure CaSO{sub 4} nanorods have active color centers without irradiation, which could be enriched/modified by these impurities mainly rare earths and further enhanced by e-beam irradiation. Eu{sup 3+} → Eu{sup 2+} conversion is clearly observed in Eu doped sample after e-beam irradiation. These results show that these nanorods might be useful in lighting and display devices development.

  9. Slow positron beam production by a 14 MeV C.W. electron accelerator

    Science.gov (United States)

    Begemann, M.; Gräff, G.; Herminghaus, H.; Kalinowsky, H.; Ley, R.

    1982-10-01

    A 14 MeV c.w. electron accelerator is used for pair production in a tungsten target of 0.7 radiation lengths thickness. A small fraction of the positrons is thermalized and diffuses out of the surface ofsurface of a well annealed tungsten foil coated with MgO which is positioned immediately behind the target. The slow positrons are extracted from the target region and magnetically guided over a distance of 10 m onto a channelplate multiplier at the end of an S-shaped solenoid. The positrons are identified by their annihilation radiation using two NaI-detectors. The intensity of the slow positrons is proportional to the accelerator electron beam current. The maximum intensity of 2.2 × 10 5 slow positrons per second reaching thedetector at an accelerator current of 15 μA was limited by the power deposited in the uncooled target. The energy of the positrons is concentrated in a small region at about 1 eV and clearly demonstrates the emission of thermal positrons.

  10. Slow positron beam production by a 14 MeV c.w. electron accelerator

    International Nuclear Information System (INIS)

    Begemann, M.; Graeff, G.; Herminghaus, H.; Kalinowsky, H.; Ley, R.

    1982-01-01

    A 14 MeV c.w. electron accelerator is used for pair production in a tungsten target of 0.7 radiation lengths thickness. A small fraction of the positrons is thermalized and diffuses out of the surface of a well annealed tungsten foil coated with MgO which is positioned immediately behind the target. The slow positrons are extracted from the target region and magnetically guided over a distance of 10 m onto a channelplate multiplier at the end of an S-shaped solenoid. The positrons are identified by their annihilation radiation using two Nal-detectors. The intensity of the slow positrons is proportional to the accelerator electron beam current. The maximum intensity of 2.2 x 10 5 slow positrons per second reaching the detector at an accelerator current of 15 μA was limited by the power deposited in the uncooled target. The energy of the positrons is concentrated in a small region at about 1 eV and clearly demonstrates the emission of thermal positrons. (orig.)

  11. 100-MeV proton beam intensity measurement by Au activation analysis using {sup 197}Au(p, pn){sup 196}Au and {sup 197}Au(p, p3n){sup 194}Au reactions

    Energy Technology Data Exchange (ETDEWEB)

    Mokhtari Oranj, Leila [Division of Advanced Nuclear Engineering, POSTECH, Pohang 37673 (Korea, Republic of); Jung, Nam-Suk; Oh, Joo-Hee [Pohang Accelerator Laboratory, POSTECH, Pohang 37673 (Korea, Republic of); Lee, Hee-Seock, E-mail: lee@postech.ac.kr [Pohang Accelerator Laboratory, POSTECH, Pohang 37673 (Korea, Republic of)

    2016-05-15

    The proton beam intensity of a 100-MeV proton linac at the Korea Multi-purpose Accelerator Complex (KOMAC) was measured by an Au activation analysis using {sup 197}Au(p, pn){sup 196}Au and {sup 197}Au(p, p3n){sup 194}Au reactions to determine the accuracy and precision of beam intensity measurement using Gafchromic film dosimetry method. The target, irradiated by 100-MeV protons, was arranged in a stack consisting of Au, Al foils and Pb plates. The yields of produced radio-nuclei in Au foils were obtained by gamma-ray spectroscopy. The FLUKA code was employed to calculate the energy spectrum of protons onto the front surface of Au foils located at three different depth points of the target and also to investigate the condition of incident beam on the target. A good agreement was found between the beam intensity measurements using the activation analysis method at three different depth points of the target. An excellent agreement was also observed between the beam intensity measurements using the Au activation analysis method and the dosimetry method using Gafchromic film.

  12. Witnessing the Future

    DEFF Research Database (Denmark)

    Elgaard Jensen, Torben

    2007-01-01

    and the problematic work life elsewhere. Finally, it notes that the manager's strategy enacts a timeworld characterised by dramatic epochal changes, which is radically different from the more stable and knowable time-world that is enacted in ordinary scientific discourses. Key words: actor-network theory, witnessing......Abstract: The paper explores the phenomenon of witnessing the future through a case study of how a Scandinavian new economy firm managed to persuade a number of business journalists that it was "the future". It describes the procedures and rhetorical strategies that the manager deployed to turn...... the journalists into witnesses. It compares the manager's strategy to other cases of effective witnessing in courtrooms and in science. It concludes that the manager's persuasiveness is derived from his ability to articulate a series of pointed contrasts between the attractive working life within the firm...

  13. Water calorimetry and ionization chamber dosimetry in an 85-MeV clinical proton beam.

    Science.gov (United States)

    Palmans, H; Seuntjens, J; Verhaegen, F; Denis, J M; Vynckier, S; Thierens, H

    1996-05-01

    In recent years, the increased use of proton beams for clinical purposes has enhanced the demand for accurate absolute dosimetry for protons. As calorimetry is the most direct way to establish the absorbed dose and because water has recently been accepted as standard material for this type of beam, the importance of water calorimetry is obvious. In this work we report water calorimeter operation in an 85-MeV proton beam and a comparison of the absorbed dose to water measured by ionometry with the dose resulting from water calorimetric measurements. To ensure a proper understanding of the heat defect for defined impurities in water for this type of radiation, a relative response study was first done in comparison with theoretical calculations of the heat defect. The results showed that pure hypoxic water and hydrogen-saturated water yielded the same response with practically zero heat defect, in agreement with the model calculations. The absorbed dose inferred from these measurements was then compared with the dose derived from ionometry by applying the European Charged Heavy Particle Dosimetry (ECHED) protocol. Restricting the comparison to chambers recommended in the protocol, the calorimeter dose was found to be 2.6% +/- 0.9% lower than the average ionometry dose. In order to estimate the significance of chamber-dependent effects in this deviation, measurements were performed using a set of ten ionization chambers of five different types. The maximum internal deviation in the ionometry results amounted to 1.1%. We detected no systematic chamber volume dependence, but observed a small but systematic effect of the chamber wall thickness. The observed deviation between calorimetry and ionometry can be attributed to a combination of the value of (Wair/e)p for protons, adopted in the ECHED protocol, the mass stopping power ratios of water to air for protons, and possibly small ionization chamber wall effects.

  14. MeV Mott polarimetry at Jefferson Lab

    International Nuclear Information System (INIS)

    Steigerwald, M.

    2001-01-01

    In the recent past, Mott polarimetry has been employed only at low electron beam energies (≅100 keV). Shortly after J. Sromicki demonstrated the first Mott scattering experiment on lead foils at 14 MeV (MAMI, 1994), a high energy Mott scattering polarimeter was developed at Thomas Jefferson National Accelerator Facility (5 MeV, 1995). An instrumental precision of 0.5% was achieved due to dramatic improvement in eliminating the background signal by means of collimation, shielding, time of flight and coincidence methods. Measurements for gold targets between 0.05 μm and 5 μm for electron energies between 2 and 8 MeV are presented. A model was developed to explain the depolarization effects in the target foils due to double scattering. The instrumental helicity correlated asymmetries were measured to smaller than 0.1%

  15. Cross section ratio and angular distributions of the reaction p + d → {sup 3}He + η at 48.8 MeV and 59.8 MeV excess energy

    Energy Technology Data Exchange (ETDEWEB)

    Adlarson, P.; Calen, H.; Fransson, K.; Gullstroem, C.O.; Heijkenskjoeld, L.; Hoeistad, B.; Johansson, T.; Marciniewski, P.; Redmer, C.F.; Wolke, M.; Zlomanczuk, J. [Uppsala University, Division of Nuclear Physics, Department of Physics and Astronomy, Box 516, Uppsala (Sweden); Augustyniak, W.; Marianski, B.; Morsch, H.P.; Trzcinski, A.; Zupranski, P. [National Centre for Nuclear Research, Department of Nuclear Physics, Warsaw (Poland); Bardan, W.; Ciepal, I.; Czerwinski, E.; Hodana, M.; Jany, A.; Jany, B.R.; Jarczyk, L.; Kamys, B.; Kistryn, S.; Krzemien, W.; Magiera, A.; Moskal, P.; Ozerianska, I.; Podkopal, P.; Rudy, Z.; Skurzok, M.; Smyrski, J.; Wronska, A.; Zielinski, M.J. [Jagiellonian University, Institute of Physics, Krakow (Poland); Bashkanov, M.; Clement, H.; Doroshkevich, E.; Perez del Rio, E.; Pricking, A.; Skorodko, T.; Wagner, G.J. [Eberhard-Karls-Universitaet Tuebingen, Physikalisches Institut, Tuebingen (Germany); Physikalisches Institut der Universitaet Tuebingen, Kepler Center fuer Astro- und Teilchenphysik, Tuebingen (Germany); Bergmann, F.S.; Demmich, K.; Goslawski, P.; Huesken, N.; Khoukaz, A.; Passfeld, A.; Taeschner, A. [Westfaelische Wilhelms-Universitaet Muenster, Institut fuer Kernphysik, Muenster (Germany); Berlowski, M.; Stepaniak, J. [National Centre for Nuclear Research, High Energy Physics Department, Warsaw (Poland); Bhatt, H.; Lalwani, K.; Varma, R. [Indian Institute of Technology Bombay, Department of Physics, Mumbai, Maharashtra (India); Buescher, M.; Engels, R.; Goldenbaum, F.; Hejny, V.; Khan, F.A.; Lersch, D.; Lorentz, B.; Maier, R.; Ohm, H.; Prasuhn, D.; Schadmand, S.; Sefzick, T.; Stassen, R.; Sterzenbach, G.; Stockhorst, H.; Stroeher, H.; Wurm, P.; Zurek, M. [Forschungszentrum Juelich, Institut fuer Kernphysik, Juelich (Germany); Forschungszentrum Juelich, Juelich Center for Hadron Physics, Juelich (Germany); Coderre, D.; Ritman, J. [Forschungszentrum Juelich, Institut fuer Kernphysik, Juelich (Germany); Forschungszentrum Juelich, Juelich Center for Hadron Physics, Juelich (Germany); Ruhr-Universitaet Bochum, Institut fuer Experimentalphysik I, Bochum (Germany); Erven, A.; Erven, W.; Kemmerling, G.; Kleines, H.; Wuestner, P. [Forschungszentrum Juelich, Juelich Center for Hadron Physics, Juelich (Germany); Forschungszentrum Juelich, Zentralinstitut fuer Engineering, Elektronik und Analytik, Juelich (Germany); Eyrich, W.; Hauenstein, F.; Krapp, M.; Zink, A. [Friedrich-Alexander-Universitaet Erlangen-Nuernberg, Physikalisches Institut, Erlangen (Germany); Fedorets, P. [Forschungszentrum Juelich, Institut fuer Kernphysik, Juelich (Germany); Forschungszentrum Juelich, Juelich Center for Hadron Physics, Juelich (Germany); State Scientific Center of the Russian Federation, Institute for Theoretical and Experimental Physics, Moscow (Russian Federation); Foehl, K. [Justus-Liebig-Universitaet Giessen, II. Physikalisches Institut, Giessen (Germany); Goswami, A. [Forschungszentrum Juelich, Institut fuer Kernphysik, Juelich (Germany); Forschungszentrum Juelich, Juelich Center for Hadron Physics, Juelich (Germany); Indian Institute of Technology Indore, Department of Physics, Indore, Madhya Pradesh (India); Grigoryev, K. [Forschungszentrum Juelich, Juelich Center for Hadron Physics, Juelich (Germany); RWTH Aachen, III. Physikalisches Institut B, Physikzentrum, Aachen (Germany); Petersburg Nuclear Physics Institute, High Energy Physics Division, Leningrad district (Russian Federation); Kirillov, D.A.; Piskunov, N.M. [Joint Institute for Nuclear Physics, Veksler and Baldin Laboratory of High Energiy Physics, Moscow region (Russian Federation); Klos, B.; Stephan, E.; Weglorz, W. [University of Silesia, August Chelkowski Institute of Physics, Katowice (Poland); Kulessa, P.; Pysz, K.; Siudak, R.; Szczurek, A. [Polish Academy of Sciences, The Henryk Niewodniczanski Institute of Nuclear Physics, Krakow (Poland); Kupsc, A.; Pszczel, D. [Uppsala University, Division of Nuclear Physics, Department of Physics and Astronomy, Box 516, Uppsala (Sweden); National Centre for Nuclear Research, High Energy Physics Department, Warsaw (Poland); Mikirtychiants, M. [Forschungszentrum Juelich, Institut fuer Kernphysik, Juelich (Germany); Forschungszentrum Juelich, Juelich Center for Hadron Physics, Juelich (DE); Ruhr-Universitaet Bochum, Institut fuer Experimentalphysik I, Bochum (DE); Petersburg Nuclear Physics Institute, High Energy Physics Division, Leningrad district (RU); Pyszniak, A. [Uppsala University, Division of Nuclear Physics, Department of Physics and Astronomy, Box 516, Uppsala (SE); Jagiellonian University, Institute of Physics, Krakow (PL); Roy, A. [Indian Institute of Technology Indore, Department of Physics, Indore, Madhya Pradesh (IN); Sawant, S. [Indian Institute of Technology Bombay, Department of Physics, Mumbai, Maharashtra (IN); Forschungszentrum Juelich, Institut fuer Kernphysik, Juelich (DE); Forschungszentrum Juelich, Juelich Center for Hadron Physics, Juelich (DE); Serdyuk, V. [Forschungszentrum Juelich, Institut fuer Kernphysik, Juelich (DE); Forschungszentrum Juelich, Juelich Center for Hadron Physics, Juelich (DE); Joint Institute for Nuclear Physics, Dzhelepov Laboratory of Nuclear Problems, Moscow region (RU); Sopov, V. [State Scientific Center of the Russian Federation, Institute for Theoretical and Experimental Physics, Moscow (RU); Yamamoto, A. [High Energy Accelerator Research Organization KEK, Tsukuba, Ibaraki (JP); Yurev, L. [Joint Institute for Nuclear Physics, Dzhelepov Laboratory of Nuclear Problems, Moscow region (RU); Zabierowski, J. [National Centre for Nuclear Research, Department of Cosmic Ray Physics, Lodz (PL); Collaboration: WASA-at-COSY Collaboration

    2014-06-15

    We present new data for angular distributions and on the cross section ratio of the p+d → {sup 3}He + η reaction at excess energies of Q = 48.8 MeV and Q = 59.8 MeV. The data have been obtained at the WASA-at-COSY experiment (Forschungszentrum Juelich) using a proton beam and a deuterium pellet target. While the shape of obtained angular distributions show only a slow variation with the energy, the new results indicate a distinct and unexpected total cross section fluctuation between Q = 20 MeV and Q = 60 MeV, which might indicate the variation of the production mechanism within this energy interval. (orig.)

  16. Status of the 1 MeV Accelerator Design for ITER NBI

    Science.gov (United States)

    Kuriyama, M.; Boilson, D.; Hemsworth, R.; Svensson, L.; Graceffa, J.; Schunke, B.; Decamps, H.; Tanaka, M.; Bonicelli, T.; Masiello, A.; Bigi, M.; Chitarin, G.; Luchetta, A.; Marcuzzi, D.; Pasqualotto, R.; Pomaro, N.; Serianni, G.; Sonato, P.; Toigo, V.; Zaccaria, P.; Kraus, W.; Franzen, P.; Heinemann, B.; Inoue, T.; Watanabe, K.; Kashiwagi, M.; Taniguchi, M.; Tobari, H.; De Esch, H.

    2011-09-01

    The beam source of neutral beam heating/current drive system for ITER is needed to accelerate the negative ion beam of 40A with D- at 1 MeV for 3600 sec. In order to realize the beam source, design and R&D works are being developed in many institutions under the coordination of ITER organization. The development of the key issues of the ion source including source plasma uniformity, suppression of co-extracted electron in D beam operation and also after the long beam duration time of over a few 100 sec, is progressed mainly in IPP with the facilities of BATMAN, MANITU and RADI. In the near future, ELISE, that will be tested the half size of the ITER ion source, will start the operation in 2011, and then SPIDER, which demonstrates negative ion production and extraction with the same size and same structure as the ITER ion source, will start the operation in 2014 as part of the NBTF. The development of the accelerator is progressed mainly in JAEA with the MeV test facility, and also the computer simulation of beam optics also developed in JAEA, CEA and RFX. The full ITER heating and current drive beam performance will be demonstrated in MITICA, which will start operation in 2016 as part of the NBTF.

  17. Status of the 1 MeV Accelerator Design for ITER NBI

    International Nuclear Information System (INIS)

    Kuriyama, M.; Boilson, D.; Hemsworth, R.; Svensson, L.; Graceffa, J.; Schunke, B.; Decamps, H.; Tanaka, M.; Bonicelli, T.; Masiello, A.; Bigi, M.; Chitarin, G.; Luchetta, A.; Marcuzzi, D.; Pasqualotto, R.; Pomaro, N.; Serianni, G.; Sonato, P.; Toigo, V.; Zaccaria, P.

    2011-01-01

    The beam source of neutral beam heating/current drive system for ITER is needed to accelerate the negative ion beam of 40A with D - at 1 MeV for 3600 sec. In order to realize the beam source, design and R and D works are being developed in many institutions under the coordination of ITER organization. The development of the key issues of the ion source including source plasma uniformity, suppression of co-extracted electron in D beam operation and also after the long beam duration time of over a few 100 sec, is progressed mainly in IPP with the facilities of BATMAN, MANITU and RADI. In the near future, ELISE, that will be tested the half size of the ITER ion source, will start the operation in 2011, and then SPIDER, which demonstrates negative ion production and extraction with the same size and same structure as the ITER ion source, will start the operation in 2014 as part of the NBTF. The development of the accelerator is progressed mainly in JAEA with the MeV test facility, and also the computer simulation of beam optics also developed in JAEA, CEA and RFX. The full ITER heating and current drive beam performance will be demonstrated in MITICA, which will start operation in 2016 as part of the NBTF.

  18. Operation of the Brookhaven 200 MeV Linac

    International Nuclear Information System (INIS)

    Fewell, N.M.; LoDestro, V.

    1979-01-01

    During the past three years the 200 MeV linear accelerator has continued to operate at a high level of performance and reliability. The linac output beam current has been limited to 60 mA in order to obtain the maximum rf power tube life without compromising the output performance of the AGS. Despite a reduction in pulse repetition rate, total beam current to the BLIP facility has increased to an average of 300 mA hours/year

  19. Development of micro-beam NRA for 3D-mapping of hydrogen distribution in solids: Application of tapered glass capillary to 6 MeV 15N ion

    International Nuclear Information System (INIS)

    Sekiba, D.; Yonemura, H.; Nebiki, T.; Wilde, M.; Ogura, S.; Yamashita, H.; Matsumoto, M.; Kasagi, J.; Iwamura, Y.; Itoh, T.; Matsuzaki, H.; Narusawa, T.; Fukutani, K.

    2008-01-01

    A micro-beam NRA system, by means of a resonant nuclear reaction 1 H( 15 N, αγ) 12 C, has been developed for the purpose of the 3D mapping of the hydrogen distribution in solids. To obtain the tens μm size of the beam spot, the combination of the newly proposed tapered glass capillary and a conventional quadrupole magnetic lens is employed. An Y patterned film on a substrate is prepared as an application of the developed system. The 6 MeV 15 N beam focused by glass capillaries down to 50 μm successfully shows the hydrogen distribution. The in-plane NRA profile implies that the beam emitted from the glass capillary outlet is parallel, although the original beam has a considerable divergence. The NRA measurements in the 10 3 Pa N 2 atmosphere due to the low gas conductance of the glass capillary is also demonstrated

  20. Study on quantum beam science by using ultra short electron pulse, FEL, and slow positron beam at ISIR (Institute of Science and Industrial Research), Osaka University

    International Nuclear Information System (INIS)

    Yoshida, Y.; Tagawa, S.; Okuda, S.; Honda, Y.; Kimura, N.; Yamamoto, T.; Isoyama, G.

    1995-01-01

    Three projects for quantum beam science, an ultra fast electron pulse, a free electron laser, and a slow positron beam, has been started by using 38 MeV L-band and 150 MeV S-band linacs at ISIR in Osaka University. Both study on the production of three beams and study on quantum material science by using three beams will play an important role in the beam science. (author)

  1. Coupled PIXE and RBS using a 6MeV 4He2+ external beam: A new experimental device for particle detection and dose monitoring

    International Nuclear Information System (INIS)

    Mathis, F.; Moignard, B.; Pichon, L.; Dubreuil, O.; Salomon, J.

    2005-01-01

    AGLAE (Accelerateur Grand Louvre d'Analyses Elementaire), the IBA facility of the 'Centre de Recherche et de Restauration des Musees de France' (C2RMF) has been equipped for several years with an external micro-beam line, in order to perform ion beam analysis on materials relevant to cultural heritage. This beam line is undergoing constant improvement. Recently, a new extraction nozzle for the external beam of the accelerator has been designed in order to obtain simultaneously from the same spot: - detection of the X-ray emission by two detectors, for low and high energies; - detection of the backscattered particles for a backscattering angle between 170 and 175 deg., thanks to an annular surface barrier detector included in the nozzle; - particle current monitoring by intermittent beam deflection on a reference material included in the system. This technical development has been induced by the study of artificial patinas on archaeological copper-alloy objects and the attempt to characterize them with a 6MeV 4 He 2+ beam, an unusual beam for this type of investigation. A detailed description of the new device and some results on an application of the use of high-energy alpha beam in PIXE and RBS made on a Roman strigil are presented here

  2. Responses of diode detectors to radiation beams from teletherapy machines

    International Nuclear Information System (INIS)

    Malinda, Lora; Nasukha

    2003-01-01

    Responses of diode detectors to radiation beams from teletherapy machines. It has been carried out responses to two sets of diode detector by using the beams of teletherapy Co-60 and medical linear accelerator. Each set of consist of 8 diode detectors was irradiated by using gamma beams from teletherapy Co-60 machines and 6 MV and 10 MV foron beams from medical linear accelerator and 6.9.12.16. and 20 MeV electron beams from medical linear accelerator. The detectors were positioned on the phantom circularly and radially and electronic equilibrium condition for all type and energy beams. It was found that every detectors had own individual response and it is not to be uniformity, since the fluctuation in between 16.6 % to 30.9 %. All detectors responses are linear to gamma and foron beams, and also for energy above 6 MeV for electron beams. Nonlinearity response occurs for 6 MeV electron beam, it is probably from the assumption of electronic equilibrium

  3. LINAC4 low energy beam measurements

    CERN Document Server

    Hein, L M; Lallement, J B; Lombardi, A M; Midttun, O; Posocco, P; Scrivens, R

    2012-01-01

    Linac4 is a 160 MeV normal-conducting linear accelerator for negative Hydrogen ions (H−), which will replace the 50 MeV proton Linac (Linac2) as linear injector for the CERN accelerators. The low energy part, comprising a 45 keV Low Energy Beam Transport system (LEBT), a 3 MeV Radiofrequency Quadrupole (RFQ) and a Medium Energy Beam Transport (MEBT) is being assembled in a dedicated test stand for pre-commissioning with a proton beam. During 2011 extensive measurements were done after the source and after the LEBT with the aim of preparing the RFQ commissioning and validating the simulation tools, indispensable for future source upgrades. The measurements have been thoroughly simulated with a multi-particle code, including 2D magnetic field maps, error studies, steering studies and the generation of beam distribution from measurements. Emittance, acceptance and transmission measurements will be presented and compared to the results of the simulations.

  4. Peripheral dose outside applicators in electron beams

    International Nuclear Information System (INIS)

    Chow, James C L; Grigorov, Grigor N

    2006-01-01

    The peripheral dose outside the applicators in electron beams was studied using a Varian 21 EX linear accelerator. To measure the peripheral dose profiles and point doses for the applicator, a solid water phantom was used with calibrated Kodak TL films. Peak dose spot was observed in the 4 MeV beam outside the applicator. The peripheral dose peak was very small in the 6 MeV beam and was ignorable at higher energies. Using the 10 x 10 cm 2 cutout and applicator, the dose peak for the 4 MeV beam was about 12 cm away from the field central beam axis (CAX) and the peripheral dose profiles did not change with depths measured at 0.2, 0.5 and 1 cm. The peripheral doses and profiles were further measured by varying the angle of obliquity, cutout and applicator size for the 4 MeV beam. The local peak dose was increased with about 3% per degree angle of obliquity, and was about 1% of the prescribed dose (angle of obliquity equals zero) at 1 cm depth in the phantom using the 10 x 10 cm 2 cutout and applicator. The peak dose position was also shifted 7 mm towards the CAX when the angle of obliquity was increased from 0 to 15 deg. (note)

  5. Alanine-EPR dosimetry in 10 MeV electron beam to optimize process parameters for food irradiation

    International Nuclear Information System (INIS)

    Sanyal, B.; Kumar, S.; Kumar, M.; Mittal, K.C.; Sharma, A.

    2011-01-01

    Absorbed dose in a food product is determined and controlled by several components of the LINAC irradiation facility as well as the product. Standardization of the parameters characterizing the facility components, process load and the irradiation conditions collectively termed as 'process parameters' are of paramount importance for successful dose delivery to the food products. In the present study alanine-EPR dosimetry system was employed to optimize the process parameters of 10 MeV electron beam of a LINAC facility for commercial irradiation of food. Three sets of experiments were carried out with different food commodities namely, mango, potato and rawa with the available product conveying system of different irradiation geometry like one sided or both sided mode of irradiation. Three dimensional dose distributions into the process load for low dose requiring food commodities (0.25 to 1 kGy) were measured in each experiment. The actual depth dose profile in food product and useful scan width of the electron beam were found out to be satisfactory for commercial radiation processing of food. Finally a scaled up experiment with commercial food product (packets of Rawa) exhibited adequate dose uniformity ratio of 3 proving the feasibility of the facility for large scale radiation processing of food commodities. (author)

  6. Electrical behaviour of butyl acrylate/methyl methacrylate copolymer films irradiated with 1.5 MeV electron beam

    Energy Technology Data Exchange (ETDEWEB)

    Radwan, R.M. [Radiation Physics Department, National Center for Radiation Research and Technology (NCRRT), Atomic Energy Authority (AEA), P. O. Box 29, Nasr City, Cairo (Egypt)], E-mail: redaradwan_2000@yahoo.com; Fawzy, Y.H.A. [Radiation Physics Department, National Center for Radiation Research and Technology (NCRRT), Atomic Energy Authority (AEA), P. O. Box 29, Nasr City, Cairo (Egypt); El-Hag Ali, A. [Polymer Chemistry Department, National Center for Radiation Research and Technology (NCRRT), Atomic Energy Authority (AEA), P. O. Box 29, Nasr City, Cairo (Egypt)

    2008-02-15

    Electrical conductivity and dielectric parameters of the (BuA/MMA) copolymer films irradiated with 1.5 MeV electron beam (EB) have been studied. The samples were irradiated with different doses of the electron beam: 5, 10, 50, 125 and 200 kGy. The electrical conductivity of the samples was found to decrease as the irradiation dose increases. The temperature dependence of the direct current (dc) conductivity for unirradiated and irradiated samples has been obtained over a temperature range from 293 to 373 K. The activation energy values were calculated for all samples. Moreover, measurements of the dielectric constant, dielectric loss and alternating current (ac) conductivity were performed at a frequency range from 100 Hz to 5 MHz at room temperature. The results indicated that the EB irradiation has formed some traps in the energy gap, which reduce the movement of the charge carriers. Furthermore, a direct proportional relationship between the activation energy and the irradiation dose was estimated in two regions: below and above the glass transition temperature of the polymer. Dipole relaxation was observed in the samples, and the dose effect was found to shift this relaxation towards higher frequencies.

  7. A neutron beam facility for radioactive ion beams and other applications

    Science.gov (United States)

    Tecchio, L. B.

    1999-06-01

    In the framework of the Italian participation in the project of a high intensity proton facility for the energy amplifier and nuclear waste transmutations, LNL is involved in the design and construction of same prototypes of the injection system of the 1 GeV linac that consists of a RFQ (5 MeV, 30 mA) followed by a 100 MeV linac. This program has already been supported financially and the work is in progress. In this context LNL has proposed a project for the construction of a second generation facility for the production of radioactive ion beams (RIBs) by means of the ISOL method. The final goal is the production of neutron rich RIBs with masses ranging from 30 to 150 by using primary beams of protons, deuterons and light ions with energy of 100 MeV and 100 kW power. This project is expected to be developed in about 10 years from new and intermediate milestones and experiments are foreseen and under consideration for the next INFN five year plan (1999-2003). During that period the construction of a proton/deuteron accelerator of 10 MeV energy and 10 mA current, consisting of a RFQ (5 MeV, 30 mA) and a linac (10 MeV, 10 mA), and of a neutron area dedicated to the RIBs production and to the neutron physics, is proposed. Some remarks on the production methods will be presented. The possibility of producing radioisotopes by means of the fission induced by neutrons will be investigated and the methods of production of neutrons will be discussed. Besides the RIBs production, neutron beams for the BNCT applications and neutron physics are also planned.

  8. Radiation Shielding Analyses of A 10 MeV, 15kW LINAC for Electron Beam and X-ray at KACST

    Energy Technology Data Exchange (ETDEWEB)

    Kang, W. G.; Pyo, S. H.; Han, B. S.; Kang, C. M. [EB Tech Co., Daejeon (Korea, Republic of); Alkhuraiji, T. S. [King AbdulAziz City for Science and Technology, Riyadh (Saudi Arabia)

    2016-10-15

    The King AbdulAziz City for Science and Technology (KACST) in the Kingdom of Saudi Arabia has a plan to build a 10 MeV, 15kW linear accelerator (LINAC) for electron beam and X-ray, which is to be supplied by EB Tech in Republic of Korea. The design and construction of the accelerator building will be carried out jointly between EB Tech and KACST. Recommendations for the design and installation of radiation shielding for x-ray and gamma-ray can be found in NCRP No. 49(1976) and for accelerators with energies over 10 MeV in NCRP No. 151 (2005). Monte Carlo calculations were conducted using the MCNP6 code to determine photon fluxes and doses at the point detectors locations around the accelerator building. The problem was run as an electron, photon and neutron transport problem to account for all reactions including the (γ,n) reaction. The detectors where the DXTRAN spheres were used are indicated in the table. The computation was continued until electrons reached a total of 1x10{sup +8} histories.

  9. Anisotropic deformation of metallo-dielectric core-shell colloids under MeV ion irradiation

    International Nuclear Information System (INIS)

    Penninkhof, J.J.; Dillen, T. van; Roorda, S.; Graf, C.; Blaaderen, A. van; Vredenberg, A.M.; Polman, A.

    2006-01-01

    We have studied the deformation of metallo-dielectric core-shell colloids under 4 MeV Xe, 6 and 16 MeV Au, 30 MeV Si and 30 MeV Cu ion irradiation. Colloids of silica surrounded by a gold shell, with a typical diameter of 400 nm, show anisotropic plastic deformation under MeV ion irradiation, with the metal flowing conform the anisotropically deforming silica core. The 20 nm thick metal shell imposes a mechanical constraint on the deforming silica core, reducing the net deformation strain rate compared to that of pure silica. In colloids consisting of a Au core and a silica shell, the silica expands perpendicular to the ion beam, while the metal core shows a large elongation along the ion beam direction, provided the silica shell is thick enough (>40 nm). A minimum electronic energy loss of 3.3 keV/nm is required for shape transformation of the metal core. Silver cores embedded in a silica shell show no elongation, but rather disintegrate. Also in planar SiO 2 films, Au and Ag colloids show entirely different behavior under MeV irradiation. We conclude that the deformation model of core-shell colloids must include ion-induced particle disintegration in combination with thermodynamical effects, possibly in combination with mechanical effects driven by stresses around the ion tracks

  10. Anisotropic deformation of metallo-dielectric core shell colloids under MeV ion irradiation

    Science.gov (United States)

    Penninkhof, J. J.; van Dillen, T.; Roorda, S.; Graf, C.; van Blaaderen, A.; Vredenberg, A. M.; Polman, A.

    2006-01-01

    We have studied the deformation of metallo-dielectric core-shell colloids under 4 MeV Xe, 6 and 16 MeV Au, 30 MeV Si and 30 MeV Cu ion irradiation. Colloids of silica surrounded by a gold shell, with a typical diameter of 400 nm, show anisotropic plastic deformation under MeV ion irradiation, with the metal flowing conform the anisotropically deforming silica core. The 20 nm thick metal shell imposes a mechanical constraint on the deforming silica core, reducing the net deformation strain rate compared to that of pure silica. In colloids consisting of a Au core and a silica shell, the silica expands perpendicular to the ion beam, while the metal core shows a large elongation along the ion beam direction, provided the silica shell is thick enough (>40 nm). A minimum electronic energy loss of 3.3 keV/nm is required for shape transformation of the metal core. Silver cores embedded in a silica shell show no elongation, but rather disintegrate. Also in planar SiO2 films, Au and Ag colloids show entirely different behavior under MeV irradiation. We conclude that the deformation model of core-shell colloids must include ion-induced particle disintegration in combination with thermodynamical effects, possibly in combination with mechanical effects driven by stresses around the ion tracks.

  11. Minimal tomography with entanglement witnesses

    OpenAIRE

    Zhu, Huangjun; Teo, Yong Siah; Englert, Berthold-Georg

    2009-01-01

    We introduce informationally complete measurements whose outcomes are entanglement witnesses and so answer the question of how many witnesses need to be measured to decide whether an arbitrary state is entangled or not: as many as the dimension of the state space. The optimized witness-based measurement can provide exponential improvement with respect to witness efficiency in high-dimensional Hilbert spaces, at the price of a reduction in the tomographic efficiency. We describe a systematic c...

  12. Waste Inspection Tomography (WIT)

    International Nuclear Information System (INIS)

    Bernardi, R.T.

    1995-01-01

    Waste Inspection Tomography (WIT) provides mobile semi-trailer mounted nondestructive examination (NDE) and assay (NDA) for nuclear waste drum characterization. WIT uses various computed tomography (CT) methods for both NDE and NDA of nuclear waste drums. Low level waste (LLW), transuranic (TRU), and mixed radioactive waste can be inspected and characterized without opening the drums. With externally transmitted x-ray NDE techniques, WIT has the ability to identify high density waste materials like heavy metals, define drum contents in two- and three-dimensional space, quantify free liquid volumes through density and x-ray attenuation coefficient discrimination, and measure drum wall thickness. With waste emitting gamma-ray NDA techniques, WIT can locate gamma emitting radioactive sources in two- and three-dimensional space, identify gamma emitting isotopic species, identify the external activity levels of emitting gamma-ray sources, correct for waste matrix attenuation, provide internal activity approximations, and provide the data needed for waste classification as LLW or TRU. The mobile feature of WIT allows inspection technologies to be brought to the nuclear waste drum storage site without the need to relocate drums for safe, rapid, and cost-effective characterization of regulated nuclear waste. The combination of these WIT characterization modalities provides the inspector with an unprecedented ability to non-invasively characterize the regulated contents of waste drums as large as 110 gallons, weighing up to 1,600 pounds. Any objects that fit within these size and weight restrictions can also be inspected on WIT, such as smaller waste bags and drums that are five and thirty-five gallons

  13. A beamline design and data acquisition with the 20-MeV, 20-ps electron beam for the higher-order mode studies of the APS SR-rf cavities

    International Nuclear Information System (INIS)

    Song, J.; Nassiri, A.; Daly, R.

    1993-01-01

    A beamline has been designed and assembled to use the ANL Chemistry Division 20-MeV electron linac for the testing of higher-order mode excitation and damping in rf cavities. The beamline consists of two sections (a beam collimating section with a 1.5 inches-OD vacuum line, and a cavity test section with a 3 inches-OD vacuum line), separated by two double aluminum foil windows. The beam diagnostics consist of a stripline beam position monitor, integrating current transformers, fluorescent screens, and a Faraday cup. EPICS (Experimental Physics and Industrial Control System) is used for beamline control, monitoring, and data acquisition. Also described is the diagnostic system used for beam image capture and analysis using EPICS-controlled hardware and PV-WAVE software. The rf cavity measurement will be described in a separate paper

  14. Design, performance, and calculated error of a Faraday cup for absolute beam current measurements of 600-MeV protons

    International Nuclear Information System (INIS)

    Beck, S.M.

    1975-04-01

    A mobile self-contained Faraday cup system for beam current measurments of nominal 600-MeV protons was designed, constructed, and used at the NASA Space Radiation Effects Laboratory. The cup is of reentrant design with a length of 106.7 cm and an outside diameter of 20.32 cm. The inner diameter is 15.24 cm and the base thickness is 30.48 cm. The primary absorber is commercially available lead hermetically sealed in a 0.32-cm-thick copper jacket. Several possible systematic errors in using the cup are evaluated. The largest source of error arises from high-energy electrons which are ejected from the entrance window and enter the cup. A total systematic error of -0.83 percent is calculated to be the decrease from the true current value. From data obtained in calibrating helium-filled ion chambers with the Faraday cup, the mean energy required to produce one ion pair in helium is found to be 30.76 +- 0.95 eV for nominal 600-MeV protons. This value agrees well, within experimental error, with reported values of 29.9 eV and 30.2 eV

  15. Design, performance, and calculated error of a Faraday cup for absolute beam current measurements of 600-MeV protons

    International Nuclear Information System (INIS)

    Beck, S.M.

    1975-04-01

    A mobile self-contained Faraday cup system for beam current measurements of nominal 600 MeV protons was designed, constructed, and used at the NASA Space Radiation Effects Laboratory. The cup is of reentrant design with a length of 106.7 cm and an outside diameter of 20.32 cm. The inner diameter is 15.24 cm and the base thickness is 30.48 cm. The primary absorber is commercially available lead hermetically sealed in a 0.32-cm-thick copper jacket. Several possible systematic errors in using the cup are evaluated. The largest source of error arises from high-energy electrons which are ejected from the entrance window and enter the cup. A total systematic error of -0.83 percent is calculated to be the decrease from the true current value. From data obtained in calibrating helium-filled ion chambers with the Faraday cup, the mean energy required to produce one ion pair in helium is found to be 30.76 +- 0.95 eV for nominal 600 MeV protons. This value agrees well, within experimental error, with reported values of 29.9 eV and 30.2 eV. (auth)

  16. Calibration of GafChromic EBT3 for absorbed dose measurements in 5 MeV proton beam and 60Co γ-rays

    International Nuclear Information System (INIS)

    Vadrucci, M.; Ronsivalle, C.; Marracino, F.; Montereali, R. M.; Picardi, L.; Piccinini, M.; Vincenti, M. A.; Esposito, G.; De Angelis, C.; Cherubini, R.; Pimpinella, M.

    2015-01-01

    Purpose: To study EBT3 GafChromic film in low-energy protons, and for comparison purposes, in a reference 60 Co beam in order to use it as a calibrated dosimetry system in the proton irradiation facility under construction within the framework of the Oncological Therapy with Protons (TOP)-Intensity Modulated Proton Linear Accelerator for RadioTherapy (IMPLART) Project at ENEA-Frascati, Italy. Methods: EBT3 film samples were irradiated at the Istituto Nazionale di Fisica Nucleare—Laboratori Nazionali di Legnaro, Italy, with a 5 MeV proton beam generated by a 7 MV Van de Graaff CN accelerator. The nominal dose rates used were 2.1 Gy/min and 40 Gy/min. The delivered dose was determined by measuring the particle fluence and the energy spectrum in air with silicon surface barrier detector monitors. A preliminary study of the EBT3 film beam quality dependence in low-energy protons was conducted by passively degrading the beam energy. EBT3 films were also irradiated at ENEA-National Institute of Ionizing Radiation Metrology with gamma radiation produced by a 60 Co source characterized by an absorbed dose to water rate of 0.26 Gy/min as measured by a calibrated Farmer type ionization chamber. EBT3 film calibration curves were determined by means of a set of 40 film pieces irradiated to various doses ranging from 0.5 Gy to 30 Gy absorbed dose to water. An EPSON Expression 11000XL color scanner in transmission mode was used for film analysis. Scanner response stability, intrafilm uniformity, and interfilm reproducibility were verified. Optical absorption spectra measurements were performed on unirradiated and irradiated EBT3 films to choose the most sensitive color channel to the dose range used. Results: EBT3 GafChromic films show an under response up to about 33% for low-energy protons with respect to 60 Co gamma radiation, which is consistent with the linear energy transfer dependence already observed with higher energy protons, and a negligible dose-rate dependence in

  17. Characteristics of a normoxic polymethacrylic acid gel dosimeter for a 72-MeV proton beam

    Science.gov (United States)

    Bong, Jihye; Shin, Dongho; Kwon, Soo-Il

    2014-01-01

    The characteristics of a normoxic polymethacrylic acid gel dosimeter for a 72-MeV proton beam were evaluated. A polymer gel dosimeter was synthesized using gelatin, methacrylic acid, hydroquinone, tetrakis(hydroxymethyl) phosphonium chloride, and highly purified distilled water. The dosimeter was manufactured by placement in a polyethylene (PE) container. Irradiated dosimeters were analyzed to determine the transverse relaxation time (T2) using a 1.5-T MRI. A calibration curve was obtained as a function of the absorbed dose. A Bragg curve made by irradiating the gel with mono-energy was compared with the results for a parallel plate ionization chamber. The spread-out Bragg peak (SOBP) range and distal dose fall-off (DDF) were comparatively analyzed by comparing the irradiated gel with a spread-out Bragg peak against with the ion chamber. Lastly, the gel's usefulness as a dosimeter for therapeutic radiation quality assurance was evaluated by obtaining its practical field size, flatness, and symmetry, through comparison of the profiles of the gel and ion chamber.

  18. Three-dimensional simulation studies of 10 MeV, 352.2 MHz drift ...

    Indian Academy of Sciences (India)

    It is proposed to build a drift tube Linac (DTL) at Raja Ramanna Centre for Advanced Technology, Indore, India, that will form a part of the future Spallation Neutron Source. This DTL will accelerate 30 mA H-ion beam from 3 MeV to 10 MeV. The DTL is designed to operate at 352.2 MHz with a maximum duty cycle of 3%.

  19. LET effects of high energy ion beam irradiation on polysilanes

    Energy Technology Data Exchange (ETDEWEB)

    Seki, Shu; Kanzaki, Kenichi; Tagawa, Seiichi; Yoshida, Yoichi [Osaka Univ., Ibaraki (Japan). Inst. of Scientific and Industrial Research; Kudoh, Hisaaki; Sugimoto, Masaki; Sasuga, Tsuneo; Seguchi, Tadao; Shibata, Hiromi

    1997-03-01

    Thin films of poly(di-n-hexylsilane) were irradiated with 2-20 MeV H{sup +} and He{sup +} ion beams. The beams caused heterogeneous reactions of crosslinking and main chain scission in the films. The relative efficiency of the crosslinking was drastically changed in comparison with that of main chain scission. The anomalous change in the molecular weight distribution was analyzed with increasing irradiation fluence, and the ion beam induced reaction radius; track radius was determined for the radiation sources by the function of molecular weight dispersion. Obtained values were 59{+-}15 A and 14{+-}6 A for 2 MeV He{sup +} and 20 MeV H{sup +} ion beams respectively. (author)

  20. Ultrashort megaelectronvolt positron beam generation based on laser-accelerated electrons

    Science.gov (United States)

    Xu, Tongjun; Shen, Baifei; Xu, Jiancai; Li, Shun; Yu, Yong; Li, Jinfeng; Lu, Xiaoming; Wang, Cheng; Wang, Xinliang; Liang, Xiaoyan; Leng, Yuxin; Li, Ruxin; Xu, Zhizhan

    2016-03-01

    Experimental generation of ultrashort MeV positron beams with high intensity and high density using a compact laser-driven setup is reported. A high-density gas jet is employed experimentally to generate MeV electrons with high charge; thus, a charge-neutralized MeV positron beam with high density is obtained during laser-accelerated electrons irradiating high-Z solid targets. It is a novel electron-positron source for the study of laboratory astrophysics. Meanwhile, the MeV positron beam is pulsed with an ultrashort duration of tens of femtoseconds and has a high peak intensity of 7.8 × 1021 s-1, thus allows specific studies of fast kinetics in millimeter-thick materials with a high time resolution and exhibits potential for applications in positron annihilation spectroscopy.

  1. Performance of the 100 MeV injector linac for the electron storage ring at Kyoto University

    International Nuclear Information System (INIS)

    Shirai, T.; Sugimura, T.; Iwashita, Y.; Kakigi, S.; Fujita, H.; Tonguu, H.; Noda, A.; Inoue, M.

    1996-01-01

    An electron linear accelerator has been constructed as an injector of a 300 MeV electron storage ring (Kaken Storage Ring, KSR) at Institute for Chemical Research, Kyoto University. The output beam energy of the linac is 100 MeV and the designed beam current is 100 mA at the 1 μsec long pulse mode. The transverse and longitudinal emittance are measured to evaluate the beam quality for the beam injection into the KSR. They are observed by the profile monitors combined with quadrupole magnets or an RF accelerator. The results are that the normalized transverse emittance is 120 π.mm.mrad. The longitudinal emittance is 15 π.deg.MeV and the energy spread is ±2.2 %. (author)

  2. New newtron time-of-flight (NTOF) facilities at the Brookhaven 200-MeV Linac

    International Nuclear Information System (INIS)

    Ward, T.E.; Alessi, J.; Brennan, J.; Grand, P.; Lankshear, R.; Snead, C.L.; Tsoupas, N.; Zucker, M.

    1988-01-01

    The installation of a new beam chopper and radio-frequency quadrupole (RFQ) preinjector (750 keV) at the Brookhaven National Laboratory (BNL) 200-MeV Linac will enable single micropulse selection (pulse width 9 pμ pulse with dc-average beam currents of 50 nA-1 μA routinely available. The NTOF facilities consists of 30-100 meter flight paths at angles of 0, 12, 30, 45, 90, and 135/degree/. Lower energies of 93, 117, 139, 161, and 181 MeV are also available as well as polarized beams at much reduced intensities. The present paper describes the new facilities, and the capabilities of future improvements and upgrades, for use in the BNL intermediate energy (p,n) experimental program. 7 refs., 2 figs., 1 tab

  3. ITER Neutral Beam Injection System

    International Nuclear Information System (INIS)

    Ohara, Yoshihiro; Tanaka, Shigeru; Akiba, Masato

    1991-03-01

    A Japanese design proposal of the ITER Neutral Beam Injection System (NBS) which is consistent with the ITER common design requirements is described. The injection system is required to deliver a neutral deuterium beam of 75MW at 1.3MeV to the reactor plasma and utilized not only for plasma heating but also for current drive and current profile control. The injection system is composed of 9 modules, each of which is designed so as to inject a 1.3MeV, 10MW neutral beam. The most important point in the design is that the injection system is based on the utilization of a cesium-seeded volume negative ion source which can produce an intense negative ion beam with high current density at a low source operating pressure. The design value of the source is based on the experimental values achieved at JAERI. The utilization of the cesium-seeded volume source is essential to the design of an efficient and compact neutral beam injection system which satisfies the ITER common design requirements. The critical components to realize this design are the 1.3MeV, 17A electrostatic accelerator and the high voltage DC acceleration power supply, whose performances must be demonstrated prior to the construction of ITER NBI system. (author)

  4. Proton-beam energy analyzer

    International Nuclear Information System (INIS)

    Belan, V.N.; Bolotin, L.I.; Kiselev, V.A.; Linnik, A.F.; Uskov, V.V.

    1989-01-01

    The authors describe a magnetic analyzer for measurement of proton-beam energy in the range from 100 keV to 25 MeV. The beam is deflected in a uniform transverse magnetic field and is registered by photographing a scintillation screen. The energy spectrum of the beam is constructed by microphotometry of the photographic film

  5. Depth profiles of production yields of natPb(p, xn206,205,204,203,202 Bi reactions using 100-MeV proton beam

    Directory of Open Access Journals (Sweden)

    Oranj Leila Mokhtari

    2017-01-01

    Full Text Available In this study, results of the experimental study on the depth profiles of production yields of 206,205,204,203,202Bi radio-nuclei in the natural Pb target irradiated by a 100-MeV proton beam are presented. Irradiation was performed at proton linac facility (KOMAC in Korea. The target, irradiated by 100-MeV protons, was arranged in a stack consisting of natural Pb, Al, Au foils and Pb plates. The proton beam intensity was determined by activation analysis method using 27Al(p, 3p1n24Na, 197Au(p, p1n196Au, and 197Au(p, p3n194Au monitor reactions and also using dosimetry method by a Gafchromic film. The production yields of produced Bi radio-nuclei in the natural Pb foils and monitor reactions were measured by gamma-ray spectroscopy. Monte Carlo simulations were performed by FLUKA, PHITS, and MCNPX codes and compared with the measurements in order to verify validity of physical models and nuclear data libraries in the Monte Carlo codes. A fairly good agreement was observed between the present experimental data and the simulations by FLUKA, PHITS, and MCNPX. However, physical models and the nuclear data relevant to the end of range of protons in the codes need to be improved.

  6. Projectile-like fragments from 129Xe+natCu reactions at E/A = 40 MeV

    International Nuclear Information System (INIS)

    Russ, D.E.; Mignerey, A.C.; Garcia-Solis, E.J.

    1996-01-01

    The bombarding of heavy nuclei with energetic heavy projectiles has been one of the most important experimental tools for nuclear science. At low beam energies, (E/A) beam 100 MeV, these mean field effects are less important and nucleon-nucleon interactions dominate. Within the intermediate energy region, the situation is less clear because of both the mean field and nucleon-nucleon effects contribute. There is no consensus on the theoretical treatment of nuclear reaction in the intermediate energy regime and statistical, dynamical, and hybrid models have been used with limited success. Previous studies of 136 Xe + 209 Bi at E/A = 28 MeV carried out at Michigan State University (MSU) have been well described by a damped reaction mechanism. On the other hand, 129 Xe + nat Cu at E/A = 50 MeV also at MSU has been compared with a hybrid model with reasonable success. In order to see a transition from a damped reaction mechanism to more fragmentation-like processes, an experiment was carried out at MSU using 129 Xe beams at E/A = 30, 40, 50, and 60 MeV. The targets were Cu, Sc, and Au. The current study only looks at the projectile-like fragments (PLF) detected in the Maryland Forward Array (MFA)

  7. Implementation of EPICS based Control System for Radioisotope Beam line

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jae-Ha; Ahn, Tae-Sung; Song, Young-Gi; Kwon, Hyeok-Jung; Cho, Yong-Sub [Korea Atomic Energy Research Institute, Gyeongju (Korea, Republic of)

    2015-10-15

    Korea Mult-purpose Accelerator Complex (KOMAC) has been operating 100 MeV proton linear accelerator . For operating 100 MeV linac, various control system has been implemented such as vacuum, power supply, RCCS and etc. KOMAC is operating two beam lines so that clients can use 100 MeV proton beam for their experiment. KOMAC sends beam to beam line and target room using two dipole magnets and several quadrupole magnets. As demand for experiments and Radius Isotope using beam is increased, another beam line is under construction and RI beam line control system is need. To synchronize with KOMAC control system, RI beam line control system is based on Experimental Physics and Industrial control System (EPICS) software. The beam is transported to RI beam line to control magnet power supply and vacuum. Implementation of RI beam line control system is presented and some preliminary results are reported. The base RI beam line control system is implemented. It can control beam direction and vacuum. Comparing archived data and current data, RI beam line and control system will be improved. In the future, scroll pump and gate control system will be implemented using programmable logic controller PLC. RI beam interlock sequence will be added to KOMAC interlock system to protect linac.

  8. Thin layer activation (TLA) experiment of piston ring F.J product by using nuclear facility proton beam 12.5 MeV

    International Nuclear Information System (INIS)

    Sudarmono; Silakhuddin

    2002-01-01

    The experiment of thin layer activation of piston ring F.J product, was done. The purpose of this experiment are to measure material wearing level by using concentration method. The experiment was carried out by activated piston ring proton beam with energy 12,5 MeV and beam current 1 μA for 30 minutes then was continued by wearing process. The measurement of the wear result activity was carried out by pouring the total of volume of lubricant oil for radioactivity measurement. Measurement of the activity level used the gamma spectroscopy. The minimum wearing duration that can detects a wear was 5 hours. The activity count was 1.230 pulse per 30 seconds which is in accordance with a wear in order of 8 mg of Fe material on 1 liter oil lubricant, this result is same with the result of T. Delvigne namely is less than 10 mgr

  9. A boost for the ISOLDE beams

    CERN Multimedia

    Corinne Pralavorio

    2015-01-01

    The first HIE-ISOLDE cryomodule was commissioned at the end of October. The radioactive ion beams can now be accelerated to 4.3 MeV per nucleon.   The ISOLDE beamline that supplies the Miniball array. The first HIE-ISOLDE cryomodule can be seen in the background, in its light-grey cryostat. ISOLDE is getting an energy boost. The first cryomodule of the new superconducting linear accelerator HIE-ISOLDE (High Intensity and Energy ISOLDE), located downstream of the REX-ISOLDE accelerator, increases the energy of the radioactive ion beams from 3 to 4.3 MeV per nucleon. It supplies the Miniball array, where an experiment using radioactive zinc ions (see box) began at the end of October. This is the first stage in the commissioning of HIE-ISOLDE. The facility will ultimately be equipped with four cryomodules that will accelerate the beams to 10 MeV per nucleon. Each cryomodule has five accelerating cavities and a solenoid, which focuses the beam. All of these components are superconducting. This first ...

  10. Status Report on the 5 Mev Iphi RFQ

    OpenAIRE

    Ferdinand, R.; Beauvais, P-Y.; Duperrier, R.; France, A.; Gaiffier, J.; Lagniel, J-M.; Painchault, M.; Simoens, F.; CEA-Saclay; DSM-DAPNIA-SEA; Balleyguier, P.; Chatel, CEA-Bruyeres le; DAM

    2000-01-01

    A 5-MeV RFQ designed for a proton current up to 100-mA CW is now under construction as part of the High Intensity Proton Injector project (IPHI). Its computed transmission is greater than 99 %. The main goals of the project are to verify the accuracy of the design codes, to gain the know-how on fabrication, tuning procedures and operations, to measure the output beam characteristics in order to optimise the higher energy part of the linac, and to reach a high availability with minimum beam tr...

  11. Cross sections measurements for the forward elastic scattering of 13 MeV 6,7 Li and 24 MeV 16 O by 9 Be, 12 C, 16 O and 28 Si

    International Nuclear Information System (INIS)

    Liendo, J.A.; Gonzalez, A.C.; Fletcher, N.R.; Caussyn, D.D.

    2001-01-01

    Full text: Absolute elastic cross sections have been measured for targets of 9 Be, 12 C 16 O, 28 Si and 197 Au being bombarded by beams of 13 MeV 6 7 Li and 24 MeV 16 O. The relevant yields were collected simultaneously at 12.450, 16.450, 20.450 and 280. The confidence of a forward elastic scattering method proposed previously to carry out multi-elemental analysis of evaporated liquid samples depends on the precision and accuracy of the cross sections reported in this work.The 24 MeV 16 0 + 197 Au reaction was used to determine the detector solid angles with uncertainties of approximately 3%. Some of the 16 O-beam reactions Some of the 16 O beam reactions have been shown to be consistent with the Rutherford formula predictions at several angles. This allowed us to obtain target thickness independent cross sections for the lithium beam initiated reactions with uncertainties close to 7%. In general, the 6 7 Li-beam reaction cross sections were found not to be consistent with the Coulomb scattering formula. In order to test the internal consistency of our measured cross sections, they were used to determine the elemental densities of several selected targets containing beryllium, carbon, oxygen and silicon. These targets were bombarded with the same beam types and energies used to measure the cross sections and, for every element of interest contained in each target, elemental density values were obtained at some of the scattering angles quoted above. Agreements between some of our results and those of a previous work support the validity of our measurements. (Author)

  12. Digital neutron/gamma discrimination with an organic scintillator at energies between 1 MeV and 100 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Comrie, A.C. [Department of Physics, University of Cape Town, Rondebosch 7700 (South Africa); Buffler, A., E-mail: andy.buffler@uct.ac.za [Department of Physics, University of Cape Town, Rondebosch 7700 (South Africa); Smit, F.D. [iThemba LABS, Somerset West 7129 (South Africa); Wörtche, H.J. [INCAS" 3, Dr. Nassaulaan 9. 9400 AT Assen (Netherlands)

    2015-02-01

    Three different digital implementations of pulse shape discrimination for pulses from an EJ301 liquid scintillator detector are presented, and illustrated with neutrons and gamma-rays produced by an Am–Be radioisotopic source, a D–T generator and beams produced by cyclotron-accelerated protons of energies 42, 62 and 100 MeV on a Li target. A critical comparison between the three methods is provided.

  13. The TRIUMF 520 MeV cyclotron: recent and future developments

    International Nuclear Information System (INIS)

    Dutto, Gerado.

    1992-08-01

    The TRIUMF cyclotron is now routinely producing 150 μA protons at 500 MeV for meson production with a maximum available current of 200 μA and beam availability of 90%. A successful resonator upgrade program, the recent commissioning of a new 92 MHz rf booster cavity and a new compact CUSP ion source will allow the current to be increased to 225 μA routinely and 300 μA maximum, once an upgrade of the high radiation target areas is completed. Furthermore, the 300 μA maximum H - internal current will allow, in parallel with 100-200 μA for meson production, the simultaneous extraction of 50-100 μA for a radioactive beam facility and of 50-100 μA for isotope production at 70-100 MeV. A proton therapy facility is also proposed. A new optically pumped H - polarized source will allow a highly stable and reproducible 5 μA beam at ∼ 75% polarization to be extracted. The feasibility of the extraction of an H - beam with electrostatic and magnetic channels has also been demonstrated. Problems and plans for the extraction of 150 μA H - for KAON will be discussed. 13 refs., 6 figs

  14. C-w operation of a 2-MeV RFQ accelerator

    International Nuclear Information System (INIS)

    Cornelius, W.D.

    1986-01-01

    We have achieved reliable cw operation of the Fusion Materials Irradiation Test (FMIT) radio-frequency quadrupole (RFQ) accelerator and have accelerated 40 mA of H 2 + beam to an energy of 2 MeV. The technical considerations for future cw accelerator designs, based on our experience in achieving cw operation, will be presented. Also to be discussed are measurements of beam emittance, matching into the RFQ, and beam transmission through the accelerator. These measurements will be compared with results of theoretical simulations of the device. The diagnostics instrumentation developed for characterizing intense cw beams also will be discussed, as well as the performance of those devices

  15. Dose properties of x-ray beams produced by laser-wakefield-accelerated electrons

    International Nuclear Information System (INIS)

    Kainz, K K; Hogstrom, K R; Antolak, J A; Almond, P R; Bloch, C D

    2005-01-01

    Given that laser wakefield acceleration (LWFA) has been demonstrated experimentally to accelerate electron beams to energies beyond 25 MeV, it is reasonable to assess the ability of existing LWFA technology to compete with conventional radiofrequency linear accelerators in producing electron and x-ray beams for external-beam radiotherapy. We present calculations of the dose distributions (off-axis dose profiles and central-axis depth dose) and dose rates of x-ray beams that can be produced from electron beams that are generated using state-of-the-art LWFA. Subsets of an LWFA electron energy distribution were propagated through the treatment head elements (presuming an existing design for an x-ray production target and flattening filter) implemented within the EGSnrc Monte Carlo code. Three x-ray energy configurations (6 MV, 10 MV and 18 MV) were studied, and the energy width ΔE of the electron-beam subsets varied from 0.5 MeV to 12.5 MeV. As ΔE increased from 0.5 MeV to 4.5 MeV, we found that the off-axis and central-axis dose profiles for x-rays were minimally affected (to within about 3%), a result slightly different from prior calculations of electron beams broadened by scattering foils. For ΔE of the order of 12 MeV, the effect on the off-axis profile was of the order of 10%, but the central-axis depth dose was affected by less than 2% for depths in excess of about 5 cm beyond d max . Although increasing ΔE beyond 6.5 MeV increased the dose rate at d max by more than 10 times, the absolute dose rates were about 3 orders of magnitude below those observed for LWFA-based electron beams at comparable energies. For a practical LWFA-based x-ray device, the beam current must be increased by about 4-5 orders of magnitude. (note)

  16. Electron Beam Scanning in Industrial Applications

    Science.gov (United States)

    Jongen, Yves; Herer, Arnold

    1996-05-01

    Scanned electron beams are used within many industries for applications such as sterilization of medical disposables, crosslinking of wire and cables insulating jackets, polymerization and degradation of resins and biomaterials, modification of semiconductors, coloration of gemstones and glasses, removal of oxides from coal plant flue gasses, and the curing of advanced composites and other molded forms. X-rays generated from scanned electron beams make yet other applications, such as food irradiation, viable. Typical accelerators for these applications range in beam energy from 0.5MeV to 10 MeV, with beam powers between 5 to 500kW and scanning widths between 20 and 300 cm. Since precise control of dose delivery is required in many of these applications, the integration of beam characteristics, product conveyance, and beam scanning mechanisms must be well understood and optimized. Fundamental issues and some case examples are presented.

  17. Ultra-High Density Electron Beams for Beam Radiation and Beam Plasma Interaction

    CERN Document Server

    Anderson, Scott; Frigola, Pedro; Gibson, David J; Hartemann, Fred V; Jacob, Jeremy S; Lim, Jae; Musumeci, Pietro; Rosenzweig, James E; Travish, Gil; Tremaine, Aaron M

    2005-01-01

    Current and future applications of high brightness electron beams, which include advanced accelerators such as the plasma wake-field accelerator (PWFA) and beam-radiation interactions such as inverse-Compton scattering (ICS), require both transverse and longitudinal beam sizes on the order of tens of microns. Ultra-high density beams may be produced at moderate energy (50 MeV) by compression and subsequent strong focusing of low emittance, photoinjector sources. We describe the implementation of this method used at LLNL's PLEIADES ICS x-ray source in which the photoinjector-generated beam has been compressed to 300 fsec duration using the velocity bunching technique and focused to 20 μm rms size using an extremely high gradient, permanent magnet quadrupole (PMQ) focusing system.

  18. Analysis of Residual Nuclide in a ACM and ACCT of 100-MeV proton beamline By measurement X-ray Spectrum

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jeong-Min; Yun, Sang-Pil; Kim, Han-Sung; Kwon, Hyeok-Jung; Cho, Yong-Sub [Korea Atomic Energy Research Institute, Gyeongju (Korea, Republic of)

    2015-10-15

    The proton beam is provides to users as various energy range from 20 MeV to 100 MeV. After protons generated from the ion source are accelerated to 100 MeV and irradiated to target through bending magnet and AC magnet. At this time, relatively high dose X-ray is emitted due to collision of proton and components of beamline. The generated X-ray is remaining after the accelerator is turned off and analyzing residual nuclides through the measurement of X-ray spectrum. Then identify the components that are the primary cause of residual nuclides are detected form the AC magnet(ACM) and associated components (ACCT). Analysis of the X-ray spectrum generated form the AC magnet(ACM) and AC current transformer(ACCT) of 100 MeV beamline according to the proton beam irradiation, most of the residual nuclides are identified it can be seen that emission in the stainless steel by beam loss.

  19. Charge steering of laser plasma accelerated fast ions in a liquid spray — creation of MeV negative ion and neutral atom beams

    International Nuclear Information System (INIS)

    Schnürer, M.; Abicht, F.; Priebe, G.; Braenzel, J.; Prasad, R.; Borghesi, M.; Andreev, A.; Nickles, P. V.; Jequier, S.; Tikhonchuk, V.; Ter-Avetisyan, S.

    2013-01-01

    The scenario of “electron capture and loss” has been recently proposed for the formation of negative ion and neutral atom beams with up to MeV kinetic energy [S. Ter-Avetisyan, et al., Appl. Phys. Lett. 99, 051501 (2011)]. Validation of these processes and of their generic nature is here provided in experiments where the ion source and the interaction medium have been spatially separated. Fast positive ions accelerated from a laser plasma source are sent through a cold spray where their charge is changed. Such formed neutral atom or negative ion has nearly the same momentum as the original positive ion. Experiments are released for protons, carbon, and oxygen ions and corresponding beams of negative ions and neutral atoms have been obtained. The electron capture and loss phenomenon is confirmed to be the origin of the negative ion and neutral atom beams. The equilibrium ratios of different charge components and cross sections have been measured. Our method is general and allows the creation of beams of neutral atoms and negative ions for different species which inherit the characteristics of the positive ion source

  20. Improvement in the 20 MeV beam brightness at Saturne

    International Nuclear Information System (INIS)

    Chamouard, P.A.; Olivier, M.

    1976-01-01

    Theoretical and experimental results are given for a program launched to improve beam brightness at Saturne. The low energy beam line located between the preinjector and linac was modified to give a reduction of beam size in the buncher and more flexible beam emittance matching with the linac acceptance, taking into account space charge effects. (E.C.B.)

  1. Design of the MYRRHA 17-600 MeV Superconducting Linac

    CERN Document Server

    Biarrotte, J-L; Bouly, F; Carneiro, J-P; Vandeplassche, D

    2013-01-01

    The goal of the MYRRHA project is to demonstrate the technical feasibility of transmutation in a 100MWth Accelerator Driven System (ADS) by building a new flexible irradiation complex in Mol (Belgium). The MYRRHA facility requires a 600 MeV accelerator delivering a maximum proton flux of 4 mA in continuous operation, with an additional requirement for exceptional reliability. This paper will briefly describe the beam dynamics design of the main superconducting linac section which covers the 17 to 600 MeV energy range and requires enhanced fault-tolerance capabilities.

  2. [Evaluation of Wits appraisal with superimposition method].

    Science.gov (United States)

    Xu, T; Ahn, J; Baumrind, S

    1999-07-01

    To compare the conventional Wits appraisal with superimposed Wits appraisal in evaluation of sagittal jaw relationship change between pre and post orthodontic treatment. The sample consists of 48-case pre and post treatment lateral head films. Computerized digitizing is used to get the cephalometric landmarks and measure conventional Wits value, superimposed Wits value and ANB angle. The correlation analysis among these three measures was done by SAS statistical package. The change of ANB angle has higher correlation with the change of superimposed Wits than that of the conventional Wits. The r-value is as high as 0.849 (P < 0.001). The superimposed Wits appraisal reflects the change of sagittal jaw relationship more objectively than the conventional one.

  3. RIKEN RI Beam Factory project

    Energy Technology Data Exchange (ETDEWEB)

    Yano, Yasushige; Goto, Akira; Katayama, Takeshi [Institute of Physical and Chemical Research, Wako, Saitama (Japan)

    1997-03-01

    The RARF proposes `RIKEN RI Beam Factory` as a next facility-expanding project. The factory makes it the primary aim to provide RI (Radioactive Isotope) beams covering over the whole atomic-mass range with the world-highest intensity in a wide energy range up to several hundreds MeV/nucleon. These RI beams are generated by the fragmentation of high-intensity heavy-ion beams. For the efficient production heavy-ion energies will be boosted up to over 100 MeV/nucleon even for very heavy ions by a K2500-MeV superconducting ring cyclotron serving as a post accelerator of the existing K540-MeV ring cyclotron. A new type of experimental installation called `MUSES` (Multi-USe Experimental Storage rings) will be constructed as well. With MUSES, various types of unique colliding experiments will become possible. (author)

  4. 200 MeV RF linac for synchrotron injection

    International Nuclear Information System (INIS)

    Whitham, K.; Anamkath, H.; Lyons, S.; Manca, J.; Miller, R.; Treas, P.; Zante, T.; Miller, R.

    1992-01-01

    Construction has been completed on an electron linear accelerator for the Brookhaven National Laboratory. This accelerator will be used for the injection of a 200 MeV electron beam into a synchrotron for lithography experiments. This paper describes the conceptual design of the linac, its e-gun pulser, and its control and timing systems. 3 figs., ref

  5. Waste inspection tomography (WIT)

    Energy Technology Data Exchange (ETDEWEB)

    Bernardi, R.T. [Bio-Imaging Research, Inc., Lincolnshire, IL (United States)

    1995-10-01

    Waste Inspection Tomography (WIT) provides mobile semi-trailer mounted nondestructive examination (NDE) and assay (NDA) for nuclear waste drum characterization. WIT uses various computed tomography (CT) methods for both NDE and NDA of nuclear waste drums. Low level waste (LLW), transuranic (TRU), and mixed radioactive waste can be inspected and characterized without opening the drums. With externally transmitted x-ray NDE techniques, WIT has the ability to identify high density waste materials like heavy metals, define drum contents in two- and three-dimensional space, quantify free liquid volumes through density and x-ray attenuation coefficient discrimination, and measure drum wall thickness. With waste emitting gamma-ray NDA techniques, WIT can locate gamma emitting radioactive sources in two- and three-dimensional space, identify gamma emitting, isotopic species, identify the external activity levels of emitting gamma-ray sources, correct for waste matrix attenuation, provide internal activity approximations, and provide the data needed for waste classification as LLW or TRU.

  6. Waste inspection tomography (WIT)

    International Nuclear Information System (INIS)

    Bernardi, R.T.

    1995-01-01

    Waste Inspection Tomography (WIT) provides mobile semi-trailer mounted nondestructive examination (NDE) and assay (NDA) for nuclear waste drum characterization. WIT uses various computed tomography (CT) methods for both NDE and NDA of nuclear waste drums. Low level waste (LLW), transuranic (TRU), and mixed radioactive waste can be inspected and characterized without opening the drums. With externally transmitted x-ray NDE techniques, WIT has the ability to identify high density waste materials like heavy metals, define drum contents in two- and three-dimensional space, quantify free liquid volumes through density and x-ray attenuation coefficient discrimination, and measure drum wall thickness. With waste emitting gamma-ray NDA techniques, WIT can locate gamma emitting radioactive sources in two- and three-dimensional space, identify gamma emitting, isotopic species, identify the external activity levels of emitting gamma-ray sources, correct for waste matrix attenuation, provide internal activity approximations, and provide the data needed for waste classification as LLW or TRU

  7. SCANDAL -- A facility for elastic neutron scattering studies in the 50--130 MeV range

    International Nuclear Information System (INIS)

    Klug, J.; Blomgren, J.; Atac, A.; Bergenwall, B.; Dangtip, S.; Elmgren, K.; Johansson, C.; Olsson, N.; Prokofiev, A.V.; Rahm, J.; Oberstedt, A.; Tovesson, F.; Eudes, Ph.; Haddad, F.; Kerveno, M.; Kirchner, T.; Lebrun, C.; Stuttge, L.; Slypen, I.; Michel, R.; Neumann, S.; Herpers, U.

    2001-01-01

    A facility for detection of scattered neutrons in the energy interval 50--130 MeV, SCANDAL (SCAttered Nucleon Detection AssembLy), has recently been installed at the 20--180 MeV neutron beam facility of the The Svedberg Laboratory, Uppsala. It is primarily intended for studies of elastic neutron scattering, but can be used for the (n,p) and (n,d) reaction experiments as well. The performance of the spectrometer is illustrated in measurements of the (n,p) and (n,n) reactions on 1 H and 12 C. In addition, the neutron beam facility is described in some detail

  8. SCANDAL--a facility for elastic neutron scattering studies in the 50-130 MeV range

    CERN Document Server

    Klug, J; Atac, A; Bergenwall, B; Dangtip, S; Elmgren, K; Johansson, C; Olsson, N; Pomp, S; Prokofiev, A V; Rahm, J; Tippawan, U; Jonsson, O; Nilsson, L; Renberg, P U; Nadel-Turonski, P; Ringbom, A; Oberstedt, A; Tovesson, F; Blideanu, V; Le Brun, C; Lecolley, J F; Lecolley, F R; Louvel, M; Marie, N; Schweitzer, C; Varignon, C; Eudes, P; Haddad, F; Kerveno, M; Kirchner, T; Lebrun, C; Stuttgé, L; Slypen, I; Smirnov, A N; Michel, R; Neumann, S; Herpers, U

    2002-01-01

    A facility for detection of scattered neutrons in the energy interval 50-130 MeV, SCAttered Nucleon Detection AssembLy (SCANDAL), has recently been installed at the 20-180 MeV neutron beam facility of The Svedberg Laboratory, Uppsala. It is primarily intended for studies of elastic neutron scattering, but can be used for (n,p) and (n,d) reaction experiments as well. The performance of the spectrometer is illustrated in measurements of the (n,p) and (n,n) reactions on sup 1 H and sup 1 sup 2 C. In addition, the neutron beam facility is described in some detail.

  9. Towards tabletop production of intense quasimonochromatic X-ray beams using small 2-20 MeV accelerators

    International Nuclear Information System (INIS)

    Avakian, R.O.; Ispirian, K.A.

    2004-01-01

    Full text: The existing synchrotron radiation sources and the fourth generation x-ray sources, which are projected at SLAC, USA, and DESY, Germany, are very expensive. For this reason the search of the novel and cheaper sources using various types of radiation produced by 5-20 MeV electrons available at many hospitals, universities and firms in various countries is of great interest. In this article a review of the physics, history, new theoretical and experimental results and of some applications is given with a purpose to consider the possibilities of construction of small tabletop sources of quasimonochromatic X-ray photon beams necessary for scientific, industrial, medicine and other applications. Simple formulae for almost all types of radiation are given with the help of which one can estimate the expected useful yield and background. PACS: 41.60.-m; 43.35.Ty; 61.85+p;m 78.67.Pt; 78.70.-g. Key words: Bremsstrahlung/Cherenkov radiation/ Transition radiation / Parametric X-ray radiation / Channeling radiation/ Compton scattering

  10. Study of the thermal oxidation of titanium and zirconium under argon ion irradiation in the low MeV range (E = 15 MeV)

    International Nuclear Information System (INIS)

    Do, N.-L.

    2012-01-01

    We have shown that argon ion irradiation between 1 and 15 MeV produces damage on both titanium and zirconium surfaces, taking the form of accelerated oxidation and/or craterization effects, varying as a function of the projectile energy and the annealing atmosphere (temperature and pressure) simulating the environmental conditions of the fuel/cladding interface of PWR fuel rods. Using AFM, we have shown that the titanium and zirconium surface is attacked under light argon ion bombardment at high temperature (up to 500 C) in weakly oxidizing medium (under rarefied dry air pressure ranging from 5,7 10 -5 Pa to 5 10 -3 Pa) for a fixed fluence of about 5 10 14 ions.cm -2 . We observed the formation of nano-metric craters over the whole titanium surface irradiated between 2 and 9 MeV and the whole zirconium surface irradiated at 4 MeV, the characteristics of which vary depending on the temperature and the pressure. In the case of the Ar/Ti couple, the superficial damage efficiency increases when the projectile energy decreases from 9 to 2 MeV. Moreover, whereas the titanium surface seems to be transparent under the 15-MeV ion beam, the zirconium surface exhibits numerous micrometric craters surrounded by a wide halo. The crater characteristics (size and superficial density) differ significantly from that observed both in the low energy range (keV) where the energy losses are controlled by ballistic collisions (Sn) and in the high energy range (MeV - GeV) where the energy losses are controlled by electronic excitations (Se), which was not completely unexpected in this intermediate energy range for which combined Sn - Se stopping power effects are possibly foreseen. Using XPS associated to ionic sputtering, we have shown that there is an irradiation effect on thermal oxidation of titanium, enhanced under the argon ion beam between 2 and 9 MeV, and that there is also an energy effect on the oxide thickness and stoichiometry. The study conducted using Spectroscopic

  11. Patterned microstructures formed with MeV Au implantation in Si(1 0 0)

    International Nuclear Information System (INIS)

    Rout, Bibhudutta; Greco, Richard R.; Zachry, Daniel P.; Dymnikov, Alexander D.; Glass, Gary A.

    2006-01-01

    Energetic (MeV) Au implantation in Si(1 0 0) (n-type) through masked micropatterns has been used to create layers resistant to KOH wet etching. Microscale patterns were produced in PMMA and SU(8) resist coatings on the silicon substrates using P-beam writing and developed. The silicon substrates were subsequently exposed using 1.5 MeV Au 3+ ions with fluences as high as 1 x 10 16 ions/cm 2 and additional patterns were exposed using copper scanning electron microscope calibration grids as masks on the silicon substrates. When wet etched with KOH microstructures were created in the silicon due to the resistance to KOH etching cause by the Au implantation. The process of combining the fabrication of masked patterns with P-beam writing with broad beam Au implantation through the masks can be a promising, cost-effective process for nanostructure engineering with Si

  12. Interaction of a 29 MeV 3{sup H}e particle beam with a Cl{sub 4}C vapour target; Interacciones de He{sup 3} de 29 MeV en un blanco de Cl{sub 4}C

    Energy Technology Data Exchange (ETDEWEB)

    Lleo Morilla, A

    1963-07-01

    The interactions of a 29 MeV 3{sup H}e particles beam on a Cl{sub 4}C vapour target have been studied using the photographic method. differential cross-sections for the Cl({sup 3}He, {sup 3}He)Cl elastic scattering and {sup 1}2C({sup 3}He, {alpha}){sup 1}1C pick-up reaction are shown; the corresponding angular distributions in the centre-of-mass system have been compared with the predictions of optical model and A.B.M. theories. (Author) 21 refs.

  13. Development of picosecond pulsed electron beam monitor. 2

    International Nuclear Information System (INIS)

    Hosono, Y.; Nakazawa, M.; Ueda, T.

    1994-01-01

    A picosecond pulsed electron beam monitor for a 35 MeV linear accelerator has been developed. The monitor consists of an electric SMA connector and aluminium pipe(inner diameter of 50mm). The following characteristics of this monitor were obtained, (a) the rise time is less than 17.5 ps (b) linearity of the monitor output voltage is proportional to the peak current of beam. It is shown that this monitor can be successfully used for bunch measurements of picosecond pulsed electron beam of 35 MeV linac. (author)

  14. Linac4 45 keV Proton Beam Measurements

    CERN Document Server

    Bellodi, G; Hein, L M; Lallement, J-B; Lombardi, A M; Midttun, O; Scrivens, R; Posocco, P A

    2013-01-01

    Linac4 is a 160 MeV normal-conducting H- linear accelerator, which will replace the 50 MeV proton Linac2 as injector for the CERN proton complex. Commissioning of the low energy part - comprising the H - source, a 45 keV Low Energy Beam Transport line (LEBT), a 3 MeV Radiofrequency Quadrupole (RFQ) and a Medium Energy Beam Transport (MEBT) - will start in fall 2012 on a dedicated test stand installation. In preparation to this, preliminary measurements were taken using a 45 keV proton source and a temporary LEBT setup, with the aim of characterising the output beam by comparison with the predictions of simulations. At the same time this allowed a first verification of the functionalities of diagnostics instrumentation and acquisition software tools. Measurements of beam profile, emittance and intensity were taken in three different setups: right after the source, after the first and after the second LEBT solenoids respectively. Particle distributions were reconstructed from emittance scan...

  15. Accelerators for E-beam and X-ray processing

    Energy Technology Data Exchange (ETDEWEB)

    Auslender, V.L. E-mail: auslen@inp.nsk.su; Bryazgin, A.A.; Faktorovich, B.L.; Gorbunov, V.A.; Kokin, E.N.; Korobeinikov, M.V.; Krainov, G.S.; Lukin, A.N.; Maximov, S.A.; Nekhaev, V.E.; Panfilov, A.D.; Radchenko, V.N.; Tkachenko, V.O.; Tuvik, A.A.; Voronin, L.A

    2002-03-01

    During last years the demand for pasteurization and desinsection of various food products (meat, chicken, sea products, vegetables, fruits, etc.) had increased. The treatment of these products in industrial scale requires the usage of powerful electron accelerators with energy 5-10 MeV and beam power at least 50 kW or more. The report describes the ILU accelerators with energy range up to 10 MeV and beam power up to 150 kW.The different irradiation schemes in electron beam and X-ray modes for various products are described. The design of the X-ray converter and 90 deg. beam bending system are also given.

  16. Characteristics of a normoxic polymethacrylic acid gel dosimeter for a 72-MeV proton beam

    Energy Technology Data Exchange (ETDEWEB)

    Bong, Jihye [Department of Medical Physics, Kyonggi University, Suwon 443-760 (Korea, Republic of); Shin, Dongho [Proton Therapy Center, National Cancer Center, Goyang 410-769 (Korea, Republic of); Kwon, Soo-Il, E-mail: sikwon@kyonggi.ac.kr [Department of Medical Physics, Kyonggi University, Suwon 443-760 (Korea, Republic of)

    2014-01-21

    The characteristics of a normoxic polymethacrylic acid gel dosimeter for a 72-MeV proton beam were evaluated. A polymer gel dosimeter was synthesized using gelatin, methacrylic acid, hydroquinone, tetrakis(hydroxymethyl) phosphonium chloride, and highly purified distilled water. The dosimeter was manufactured by placement in a polyethylene (PE) container. Irradiated dosimeters were analyzed to determine the transverse relaxation time (T2) using a 1.5-T MRI. A calibration curve was obtained as a function of the absorbed dose. A Bragg curve made by irradiating the gel with mono-energy was compared with the results for a parallel plate ionization chamber. The spread-out Bragg peak (SOBP) range and distal dose fall-off (DDF) were comparatively analyzed by comparing the irradiated gel with a spread-out Bragg peak against with the ion chamber. Lastly, the gel's usefulness as a dosimeter for therapeutic radiation quality assurance was evaluated by obtaining its practical field size, flatness, and symmetry, through comparison of the profiles of the gel and ion chamber.

  17. Neutron scattering differential cross sections of carbon and bismuth at 37 MeV

    International Nuclear Information System (INIS)

    Zhou Zuying; Tang Hongqing; Qi Bujia; Zhou Chenwei; Du Yanfeng; Xia Haihong; Walter, R.L.; Tornow, W.; Howell, C.; Braun, R.; Roper, C.; Chen Zemin; Chen Zhengpeng; Chen Yingtang

    1997-01-01

    Elastic differential cross sections of 37 MeV neutrons scattered from carbon and bismuth were measured in the angular range 11 to 160 degrees by means of the multi-detector TOF facility. The 37 MeV neutrons were produced via the T(d,n) 4 He reaction in a tritium gas target. The pulsed 20 MeV deuteron beam was provided by the HI-13 tandem accelerator. The angular distribution of scattered neutrons from carbon and bismuth were measured in the angular range 11 degree to 145 degree and 11 degree to 160 degree respectively in steps of about 3 degree

  18. Long-pulse beam acceleration of MeV-class H(-) ion beams for ITER NB accelerator.

    Science.gov (United States)

    Umeda, N; Kashiwagi, M; Taniguchi, M; Tobari, H; Watanabe, K; Dairaku, M; Yamanaka, H; Inoue, T; Kojima, A; Hanada, M

    2014-02-01

    In order to realize neutral beam systems in International Thermonuclear Experimental Reactor whose target is to produce a 1 MeV, 200 A/m(2) during 3600 s D(-) ion beam, the electrostatic five-stages negative ion accelerator so-called "MeV accelerator" has been developed at Japan Atomic Energy Agency. To extend pulse length, heat load of the acceleration grids was reduced by controlling the ion beam trajectory. Namely, the beam deflection due to the residual magnetic field of filter magnet was suppressed with the newly developed extractor with a 0.5 mm off-set aperture displacement. The new extractor improved the deflection angle from 6 mrad to 1 mrad, resulting in the reduction of direct interception of negative ions from 23% to 15% of the total acceleration power, respectively. As a result, the pulse length of 130 A/m(2), 881 keV H(-) ion beam has been successfully extended from a previous value of 0.4 s to 8.7 s. This is the first long pulse negative ion beam acceleration over 100 MW/m(2).

  19. The ANL 50 MeV H- Injector: 35 year anniversary

    International Nuclear Information System (INIS)

    Stipp, V.; Brumwell, F.; McMichael, G.

    1996-01-01

    The H - Injector at ANL consists of a 750 keV Cockcroft-Walton preaccelerator and an Alvarez type 50 MeV Linac. The accelerator was originally constructed as the source of protons for the Zero Gradient Synchrotron (ZGS). The first proton beam was extracted from the preaccelerator in 1961. The accelerator is presently used as the injector for the Intense Pulsed Neutron Source (IPNS), a 500 MeV rapid cycling synchrotron with a spallation-neutron target. During most of the time since turn-on over 15 years ago, the IPNS facility availability has rarely dropped below 90% and has averaged 95% over the last ten years. During the same period, the 50 MeV injector availability has averaged 99%. Performance and improvements over the 35 year period is discussed

  20. The beam commissioning of BRIF and future cyclotron development at CIAE

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Tianjue, E-mail: tjzhang@ciae.ac.cn; Yang, Jianjun, E-mail: yangjianjun2000@tsinghua.org.cn

    2016-06-01

    As an upgrade project of the existing HI-13 tandem accelerator facility, the Beijing Radioactive Ion-beam Facility (BRIF) is being constructed in China Institute of Atomic Energy (CIAE). This project consists of an 100 MeV proton compact cyclotron, a two-stage ISOL system, a superconducting linac booster and various experimental terminals. The beam commissioning of the cyclotron was launched by the end of 2013 and on July 4, 2014 the first 100 MeV proton beam was received on a temporary target which was positioned at the outlet of the cyclotron. The beam current was stably maintained at above 25 μA for about 9 h on July 25, 2014 and the cyclotron is now ready for providing CW proton beam on target-source for RIB production. The beam current is expected to be increased to 200–500 μA in the coming years. The installation of the ISOL system is finished and the stable ion beam test shows it can reach a mass resolution better than 10,000. It is expected to generate dozens of RIB by 100 MeV proton beam. In addition, this paper also introduces the recent progress of the pre-study of an 800 MeV, 3–4 MW separate-sector proton cyclotron, which is aimed to provide high power proton beam for various applications, such as neutron and neutrino physics, proton radiography and nuclear data measurement and ADS system.

  1. Overview of the APT high-energy beam transport and beam expanders

    International Nuclear Information System (INIS)

    Shafer, R.E.; Blind, B.; Gray, E.R.

    1997-01-01

    The APT high energy beam transport (HEBT) and beam expanders convey the 1700-MeV, 100-mA cw proton beam from the linac to the tritium target/blanket assembly, or a tuning beam stop. The HEBT includes extensive beam diagnostics, collimators, and beam jitter correction, to monitor and control the 170-MW beam prior to expansion. A zero-degree beamline conveys the beam to the beam stop, and an achromatic bend conveys the beam to the tritium production target. Nonlinear beam expanders make use of higher-order multipole magnets and dithering dipoles to expand the beam to a uniform-density, 16-cm wide by 160-cm high rectangular profile on the tritium-production target. The overall optics design will be reviewed, and beam simulations will be presented

  2. Thermoluminescence properties of Al{sub 2}O{sub 3}:Tb nanoparticles irradiated by gamma rays and 85 MeV C{sup 6+} ion beam

    Energy Technology Data Exchange (ETDEWEB)

    Salah, Numan, E-mail: nsalah@kau.edu.sa [Center of Nanotechnology, King Abdulaziz University, Jeddah 21589 (Saudi Arabia); Alharbi, Najlaa D. [Sciences Faculty for Girls, King Abdulaziz University, Jeddah 21589 (Saudi Arabia); Habib, Sami S. [Center of Nanotechnology, King Abdulaziz University, Jeddah 21589 (Saudi Arabia); Lochab, S.P. [Inter-University Accelerator Centre, Aruna Asaf Ali Marg, New Delhi 110067 (India)

    2015-11-15

    Carbon ions beam is recently recognized as an ideal cancer treatment modality, because of its excellent local tumor control. These ions have a high relative biological effectiveness resulting from high linear energy transfer (LET) and their sharp Bragg peak. However, the dose of those energetic ions needs to be measured with great precision using a proper dosimeter. Aluminum Oxide (Al{sub 2}O{sub 3}) is a highly luminescent phosphor widely used for radiation dosimetry using thermoluminesence (TL) technique. In this work nanoparticles of this material activated by different elements like Eu, Tb, Dy, Cu and Ag were evaluated for their TL response to gamma rays irradiation. Tb doped sample is found to be the most sensitive sample, which could be selected for exposure to 85 MeV C{sup 6+} ion beam in the fluence range 10{sup 9}–10{sup 13} ions/cm{sup 2}. The obtained result shows that C ion beam irradiated sample has a simple glow curve structure with a prominent glow peak at around 230 °C. This glow curve has a dosimetric peak better than those induced by gamma rays. This glow peak exhibits a linear response in the range 10{sup 9}–10{sup 11} ions/cm{sup 2}, corresponding to the equivalent absorbed doses 0.285–28.5 kGy. The absorbed doses, penetration depths and main energy loss were calculated using TRIM code based on the Monte Carlo simulation. The wide linear response of Al{sub 2}O{sub 3}:Tb nanoparticles along with the low fading makes this low cost nanomaterial a good candidate for C ion beam dosimetry. - Highlights: • Nanoparticles of Al{sub 2}O{sub 3} doped with Eu, Tb, Dy, Cu and Ag were synthesised. • They were evaluated for their TL response to gamma rays and C ion beam irradiation. • Tb doped sample is the most sensitive sample to gamma rays. • Al{sub 2}O{sub 3}:Tb was exposed to 85 MeV C{sup 6+} ion beam in the fluence range 10{sup 9}-10{sup 13} ions/cm{sup 2}. • The glow peak induced by C ions has a linear response in the range 10{sup 9

  3. Thickness optimization and activity induction in beam slit monitor for Indus

    International Nuclear Information System (INIS)

    Petwal, V.C.; Pramod, R.; Dwivedi, Jishnu; Senecha, V.K.

    2009-01-01

    A large number of beam slit monitors are planned to be installed in the TL-2 and TL-3 of Indus for probing the 450 MeV and 700 MeV electron beams. The beam slit monitor consists of 2 pairs of metallic blades, mounted in orthogonal direction and shall be installed inside the beam chamber. These shutters provide current signals, on interception with electron beam, which can be used to determine precisely beam position, shape and size. The physical dimensions of the shutter blades are of crucial importance due to the requirement of high resolution, accuracy and space constraints. As part of design study of beam slit monitors, Monte Carlo simulation using MCNP code has been performed to investigate the radiological characteristics of the suitable blade materials e.g. Cu, Ta, W, and Inermet. The thickness has been optimised to absorb 90% of electron beam. The power density profiles along thickness and radial direction have been simulated to carry out thermal design. The high energy electron beam on interception with shutter blade develops cascading shower, containing secondary particles such as photons, photoneutrons, pions, and muons etc, which induce radioactivity in shutter material as well in the surrounding components. The state of the art Monte Carlo Code FLUKA has been used to estimate the amount of the activity induced in the shutter blade. In the first step, the FLUKA calculations are compared with data reported in IAEA TRS 188 for Cu, W target in the energy range 15 - 35 MeV, which shows good agreement. In second step, these calculations are extended to estimate induced activity in the shutter blade at actual electron energy 450 MeV and 700 MeV. (author)

  4. Study of LiF:Mg,Ti and CaSO4:Dy dosimeters TL response to electron beams of 6 MeV applied to radiotherapy using PMMA and solid water phantoms

    International Nuclear Information System (INIS)

    Bravim, A.; Sakuraba, R.K.; Cruz, J.C.; Campos, L.L.

    2011-01-01

    The performance of CaSO 4 :Dy and LiF:Mg,Ti dosimeters to electron beams applied to radiotherapy was investigated. The TL response of these dosimeters was studied for 6 MeV electron beams using PMMA and Solid Water (SW) phantoms. The dosimeters were previously separated in groups according to their TL individual sensitivities to 60 Co gamma-radiation in air under electronic equilibrium conditions. After that, they were irradiated with 6 MeV electron doses of 0.1, 0.5, 1, 5 and 10 Gy using a linear accelerator Clinac 2100C Varian of Hospital Israelita Albert Einstein – HIAE. The electron beam irradiations were performed using a 10 × 10 cm 2 field size, 100 cm source-phantom surface distance and the dosimeters were positioned at the depth of maximum dose (1.2 cm). The TL readings were carried out between 24 and 32 h after irradiation using a Harshaw 3500 TL reader. The TL dose–response of both type of dosimeters and phantoms presented linear behavior on the electron dose range from 0.1 to 5 Gy CaSO 4 :Dy dosimeter is 21 times more sensitive than LiF:Mg,Ti, dosimeter commonly used in clinical dosimetry. The obtained results indicate that the performance of CaSO 4 :Dy dosimeters is similar to LiF:Mg,Ti dosimeters and this material can be an alternative dosimetric material to be used to clinical electron beams dosimetry.

  5. Effects of sawtooth crashes on beam ions and fusion product tritons in JET

    Energy Technology Data Exchange (ETDEWEB)

    Marcus, F B; Hone, M A; Jarvis, O N; Loughlin, M J; Sadler, G [Commission of the European Communities, Abingdon (United Kingdom). JET Joint Undertaking; Adams, J M; Bond, D S; Watkins, N [UKAEA Harwell Lab. (United Kingdom). Energy Technology Div.; Howarth, P J.A. [Birmingham Univ. (United Kingdom)

    1994-07-01

    The effect of a sawtooth crash on the radial distribution of the slowing down fusion product tritons and on beams ions, is examined with measurements of the 2.5 MeV and 14 MeV neutron emission line-integrals before and after sawtooth crashes. In deuterium discharges, the 14 MeV neutron production was wholly attributable to burnup of the 1 MeV fusion product tritons from d-d fusion. The local emissivity of 14 MeV neutrons, and hence of the profile of thermalizing tritons, is shown to be only weakly affected by crashes in the discharges studied. This is in contradiction with the apparent behaviour of injected beam ions as deduced from a study of the considerable changes in local emissivity of the 2.5 MeV neutrons. Nevertheless, the behaviour of the fusion product tritons is consistent with the scaling of the beam injected deuterium. 1 ref., 6 figs.

  6. Effects of sawtooth crashes on beam ions and fusion product tritons in JET

    International Nuclear Information System (INIS)

    Marcus, F.B.; Hone, M.A.; Jarvis, O.N.; Loughlin, M.J.; Sadler, G.

    1994-01-01

    The effect of a sawtooth crash on the radial distribution of the slowing down fusion product tritons and on beams ions, is examined with measurements of the 2.5 MeV and 14 MeV neutron emission line-integrals before and after sawtooth crashes. In deuterium discharges, the 14 MeV neutron production was wholly attributable to burnup of the 1 MeV fusion product tritons from d-d fusion. The local emissivity of 14 MeV neutrons, and hence of the profile of thermalizing tritons, is shown to be only weakly affected by crashes in the discharges studied. This is in contradiction with the apparent behaviour of injected beam ions as deduced from a study of the considerable changes in local emissivity of the 2.5 MeV neutrons. Nevertheless, the behaviour of the fusion product tritons is consistent with the scaling of the beam injected deuterium. 1 ref., 6 figs

  7. Pulse compression system for the ANL 20 MeV linac

    International Nuclear Information System (INIS)

    Mavrogenes, G.; Norem, J.; Simpson, J.

    1986-01-01

    This paper describes the pulse compression system being built on the Argonne 20 MeV electron linac. The system is designed to rotate the bunch from the present measured pulse length of 38 psec FWHM, to pulse lengths of 5 to 6 ps with the large instantaneous currents (1 to 4 kA) possible instantaneous current. This system was necessary to extend the study of reactive fragments of molecules to the time scale of a few picoseconds, in particular to examine the chemistry of electrons and ions before and during relaxation of the surrounding media. These experiments are not sensitive to the beam energy spread, High Energy Physics experiments studying wake fields have also been proposed using the short bunches and the facility was designed so that the wake field experiment could share the beam bunching system. The 20 MeV electron linac uses a double gap, 12th subharmonic prebuncher together with a one wavelength 1.3 Ghz prebuncher to produce a single pulse of 38 ps from one occupied rf bucket. Beam emittances of 15.7 mmmr have been measured for 40 nC of accelerated charge and 8 mmmr at 10 nC. The energy spread of dE/E = 1% (FWHM) has been measured at 40 nC. Thus the accelerated beam has excellent time structure, high current, and good emittance

  8. High-gradient two-beam electron accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Hirshfield, Jay L. [Omega-P, Inc., New Haven, CT (United States)

    2014-11-04

    The main goal for this project was to design, build, and evaluate a detuned-cavity, collinear, two-beam accelerator structure. Testing was to be at the Yale University Beam Physics Laboratory, under terms of a sub-grant from Omega-P to Yale. Facilities available at Yale for this project include a 6-MeV S-band RF gun and associated beam line for forming and transporting a ~1 A drive beam , a 300 kV beam source for use as a test beam, and a full panoply of laboratory infrastructure and test equipment. During the first year of this project, availability and functionality of the 6-MeV drive beam and 300 kV test beam were confirmed, and the beam line was restored to a layout to be used with the two-beam accelerator project. Major efforts during the first year were also focused on computational design and simulation of the accelerator structure itself, on beam dynamics, and on beam transport. Effort during the second year was focussed on building and preparing to test the structure, including extensive cold testing. Detailed results from work under this project have been published in twelve archival journal articles, listed in Section IV of the technical report.

  9. Water equivalence of some plastic-water phantom materials for clinical proton beam dosimetry

    International Nuclear Information System (INIS)

    Al-Sulaiti, L.; Shipley, D.; Thomas, R.; Owen, P.; Kacperek, A.; Regan, P.H.; Palmans, H.

    2012-01-01

    Plastic-water phantom materials are not exactly water equivalent since they have a different elemental composition and different interaction cross sections for protons than water. Several studies of the water equivalence of plastic-water phantom materials have been reported for photon and electron beams, but none for clinical proton beams. In proton beams, the difference between non-elastic nuclear interactions in plastic-water phantom materials compared to those in water should be considered. In this work, the water equivalence of Plastic Water ® (PW) 1 , Plastic Water ® Diagnostic Therapy (PWDT) 1 and solid water (WT1) 2 phantoms was studied for clinical proton energies of 60 MeV and 200 MeV. This was done by evaluating the fluence correction factor at equivalent depths; first with respect to water and then with respect to graphite by experiment and Monte Carlo (MC) simulations using FLUKA. MC simulations showed that the fluence correction with respect to water was less than 0.5% up to the entire penetration depth of the protons at 60 MeV and less than 1% at 200 MeV up to 20 cm depth for PWDT, PW and WT1. With respect to graphite the fluence correction was about 0.5% for 60 MeV and about 4% for 200 MeV. The experimental results for modulated and un-modulated 60 MeV proton beams showed good agreement with the MC simulated fluence correction factors with respect to graphite deviating less than 1% from unity for the three plastic-water phantoms. - Highlights: ► We study plastic-water in clinical proton beams by experiment and Monte Carlo. ► We obtain fluence correction factors for water and graphite. ► The correction factor for water was close to 1 at 60 MeV and <0.990 at 200 MeV. ► The correction factor for graphite was ∼0.5% at 60 MeV and up to 4% at 200 MeV.

  10. Number transmission of 0.6 and 0.8MeV electrons in elemental materials

    International Nuclear Information System (INIS)

    Harami, Taikan; Takagaki, Torao; Matsuda, Koji; Nakai, Yohta.

    1975-01-01

    The number transmissions of electrons in Be, Al, Cu and Ag were obtained experimentally for well collimated electron beams of 0.6 and 0.8 MeV. Experimental results of the present work join smoothly to the previous ones of 1.0 MeV to 2.0 MeV electrons. The ratios of extrapolated range Rsub(ex) to true range R 0 give generally minimum values near 1 MeV (approximately 2mc 2 ) as well as the stopping power. An investigation was done for empirical equation of the form eta=exp(-xP/CEsup(m)), where E is the incident electron energy, x, penetration depth, and p, C and m are the parameters determined from experimental data. (author)

  11. 1 1/2 years of experience with a 10 MeV self-shielded on-line e-beam sterilization system

    International Nuclear Information System (INIS)

    Lambert, Byron; Tang, Fuh-Wei; Riggs, Brian; Allen, Thomas; Williams, C.B.

    2000-01-01

    The Vascular Intervening Group of the Guidant Corporation (Guidant IV) has been operating a self-shielded, 10 MeV 4 kW, electron beam sterilization system since July of 1988. The system was designed, built and installed in a 70 square meter area in an existing Guidant manufacturing facility by Titan Scan Corporation and performance of the system was validated in conformance with 1S0-11137 standards. The goal of this on-site e-beam system was 'just in time' JIT, sterilization, i.e. the ability to manufacture, sterilize and ship, high intrinsic value medical devices in less than 24 hours. The benefits of moving from a long gas sterilization cycle of greater than one week to a JIT process were envisioned to be a) speed to market with innovated new products b) rapid response to customer requirements c) reduced inventory carrying costs and finally manufacturing and quality system efficiency. The ability of Guidant to realize these benefits depended upon the ability of the Guidant VI business units to adapt to the new sterilization modality and functionality and on the overall system reliability. This paper reviews the operating experience to date and the overall system reliability. (author)

  12. 41 CFR 105-70.033 - Witnesses.

    Science.gov (United States)

    2010-07-01

    ... 41 Public Contracts and Property Management 3 2010-07-01 2010-07-01 false Witnesses. 105-70.033 Section 105-70.033 Public Contracts and Property Management Federal Property Management Regulations System... may proceed by leading questions only if the witness is a hostile witness, an adverse party, or a...

  13. Experimental Observations of Nuclear Activity in Deuterated Materials Subjected to a Low-Energy Photon Beam

    Science.gov (United States)

    Steinetz, Bruce M.; Benyo, Theresa L.; Pines, Vladimir; Pines, Marianna; Forsley, Lawrence P.; Westmeyer, Paul A.; Chait, Arnon; Becks, Michael D.; Martin, Richard E.; Hendricks, Robert C.; hide

    2017-01-01

    Exposure of highly deuterated materials to a low-energy (nom. 2 MeV) photon beam resulted in nuclear activity of both the parent metals of hafnium and erbium and a witness material (molybdenum) mixed with the reactants. Gamma spectral analysis of all deuterated materials, ErD2.8+C36D74+Mo and HfD2+C36D74+Mo, showed that nuclear processes had occurred as shown by unique gamma signatures. For the deuterated erbium specimens, posttest gamma spectra showed evidence of radioisotopes of erbium ((163)Er and (171)Er) and of molybdenum ((99)Mo and (101)Mo) and by beta decay, technetium (99mTc and 101Tc). For the deuterated hafnium specimens, posttest gamma spectra showed evidence of radioisotopes of hafnium (180mHf and 181Hf) and molybdenum ((99)Mo and (101)Mo), and by beta decay, technetium ((99m)Tc and (101)Tc). In contrast, when either the hydrogenated or non-gas-loaded erbium or hafnium materials were exposed to the gamma flux, the gamma spectra revealed no new isotopes. Neutron activation materials showed evidence of thermal and epithermal neutrons. CR-39 solid-state nuclear track detectors showed evidence of fast neutrons with energies between 1.4 and 2.5 MeV and several instances of triple tracks, indicating (is) greater than 10 MeV neutrons. Further study is required to determine the mechanism causing the nuclear activity.

  14. Charged--particle beam implosion of fusion targets

    International Nuclear Information System (INIS)

    Clauser, M.J.; Sweeney, M.A.

    1975-01-01

    This paper discusses the calculated behavior of fusion targets consisting of solid shells filled with DT gas, irradiated by high power electron or ion beams. The current required for breakeven with gold shells is 500 to 1000 MA, independent of target radius and nearly independent of beam voltage in the 1 / 2 to 1 MeV range. Above 1 MeV the breakeven current increases because of the increased bremsstrahlung production by the beam electrons. By using a diamond ablator and a gold pusher, the breakeven current is reduced to 220 MA. The ion current required for breakeven (about 10 MA of protons) is independent of proton voltage above 10 MeV with gold shell targets. Below 10 MeV the range of the proton becomes too short for efficient coupling, and the required current increases, but the power does not. Various aspects of the symmetry and stability of the implosion are discussed. One finds that the relatively long deposition lengths of electrons result in relatively small growths of the Rayleigh--Taylor instability during the acceleration of the pusher, resulting in a relatively stable implosion

  15. PROTECTION OF THREATENED WITNESSES

    Directory of Open Access Journals (Sweden)

    Nadia Claudia CANTEMIR-STOICA

    2016-05-01

    Full Text Available First, I wish to make a presentation of historically institution and subsequently parallels between past and current regulators to expose whether the legislature has reached desire - namely ensuring effective protection of witnesses threatened and vulnerable. Also, I decided to analyze the topic from the perspective of the criminal procedural provisions of Law 682/2002 and witness protection, which are republished to expose the conditions and criteria by which to ensure this status. I also want to present besides theoretical and practical ways in which the National Office for Witness Protection gives effective legal provisions. Not least, I will bring criticism of current regulation and not by law ferenda proposals.

  16. Multipole Stack for the 800 MeV PS Booster

    CERN Multimedia

    1975-01-01

    The 800 MeV PS Booster had seen first beam in its 4 superposed rings in 1972, routine operation began in 1973. In the strive for ever higher beam intensities, the need for additional multipole lenses became evident. After detailed studies, the manufacture of 8 stacks of multipoles was launched in 1974. Each stack consists of 4 superposed multipoles and each multipole has 4 concentric shells. From the innermost to the outermost shell, Type A contains octupole, skew-octupole, sextupole, skew-sextupole. Type B contains skew-octupole, skew-sextupole, vertical dipole, horizontal dipole. Completion of installation in 1976 opened the way to higher beam intensities. M. Battiaz is seen here with a multipole stack and its many electrical connections.

  17. 47 CFR 1.339 - Witness fees.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Witness fees. 1.339 Section 1.339....339 Witness fees. Witnesses who are subpenaed and respond thereto are entitled to the same fees, including mileage, as are paid for like service in the courts of the United States. Fees shall be paid by...

  18. Determination of the neutron energy and spatial distributions of the neutron beam from the TSR-II in the large beam shield

    International Nuclear Information System (INIS)

    Clifford, C.E.; Muckenthaler, F.J.

    1976-01-01

    The TSR-II reactor of the ORNL Tower Shielding Facility has recently been relocated within a new, fixed shield. A principal feature of the new shield is a beam port of considerably larger area than that of its predecessor. The usable neutron flux has thereby been increased by a factor of approximately 200. The bare beam neutron spectrum behind the new shield has been experimentally determined over the energy range from 0.8 to 16 MeV. A high level of fission product gamma ray background prevented measurement of bare beam spectra below 0.8 MeV, however neutron spectra in the energy range from 8 keV to 1.4 MeV were obtained for two simple, calculable shielding configurations. Also measured in the present work were weighted integral flux distributions and fast neutron dose rates

  19. A 600 MeV cyclotron for radioactive beam production

    International Nuclear Information System (INIS)

    Clark, D.J.

    1993-01-01

    The magnetic field design for a 600 MeV proton cyclotron is described. The cyclotron has a single stage, a normal conducting magnet coil and a 9.8 m outside yoke diameter. It has 8 sectors, with a transition to 4 sectors in the center region. The magnetic field design was done using 1958 Harwell rectangular ridge system measurements and was compared with recent 3-dimensional field calculations with the program TOSCA at NSCL. The center region 4--8 sector transition focussing was also checked with TOSCA

  20. Tests of health physics detectors and dosimeters to 6 and 9 MeV gamma-radiation

    International Nuclear Information System (INIS)

    1982-04-01

    The CEA health physicists working group on standardization and testing of detectors for the measurements of external exposure has set up and calibrated a capture #betta# beam. 6 and 9 MeV energies were obtained by means of Ti and Ni targets. These beams made it possible to determine the response of a number of detectors and dosimeters used in health physics to these energy ranges. Most generally, these tests showed that at 6 or 9 MeV the responses of instruments calibrated with 60 Co #betta#-rays could vary as much as a factor 2 when compared to the maximun of the absorbed dose in a human body [fr

  1. The gas bubbles distribution in 600 MeV protons irradiated aluminium

    International Nuclear Information System (INIS)

    Gavillet, D.; Martin, J.L.; Victoria, M.; Green, W.

    1984-01-01

    In order to simulate the damage produced by 14 MeV fusion neutrons, thin foils of high purity Al have been irradiated by a proton beam of 580 MeV (120μA). After irradiation at temperatures higher than 0.5 Tm transmission electron microscope observations of gas bubbles distribution were performed. At 200 0 C a uniform distribution of bubbles has been observed inside the grain. The average distance between bubbles and their density have been determined. The gas pressure inside the bubbles has been estimated [fr

  2. ETHIOPIAN WITNESS PROTECTION SYSTEM: COMPARATIVE ...

    African Journals Online (AJOL)

    witness protection involves social cohesion of the protected person. Scholars ..... interests' need to balance an accused right to know and confront prosecution ..... was reduced to 2.5 years through the fast tracking of witness protection cases.

  3. First beam in Linac4 DTL

    CERN Multimedia

    Katarina Anthony

    2014-01-01

    Following the installation of the Linac4 Drift Tube Linac (DTL) earlier this summer (see here), the first DTL tank saw beams at 12 MeV on 5 August.   Transverse emittance measured at 12 MeV after the DTL tank1 using a temporary slit-and-grid emittance device. You never forget your first beam. That was especially true for the Linac4 DTL team, as it followed years of design, construction and vigorous testing. "We performed countless measurements of the geometry, vacuum and magnet polarisation of the DTL tanks while we were in the workshop," says Suitbert Ramberger, project engineer for the Linac4 DTL. "Add that preparation to the excellent RF conditioning that we carried out in the weeks before the beam tests and I was confident that the acceleration with beam would fully meet expectations!" Indeed it did. Beam commissioning tests ran until 21 August and found the DTL operating with nominal transmission. This successful run has confirmed the innovative design ...

  4. Low energy spread 100 MeV-1 GeV electron bunches from laser wakefield acceleration at LOASIS

    International Nuclear Information System (INIS)

    Geddes, C.G.R.; Esarey, E.; Michel, P.; Nagler, B.; Nakamura, K.; Plateau, G.R.; Schroeder, C.B.; Shadwick, B.A.; Toth, Cs.; Van Tilborg, J.; Leemans, W.P.; Hooker, S.M.; Gonsalves, A.J.; Michel, E.; Cary, J.R.; Bruhwiler, D.

    2006-01-01

    Experiments at the LOASIS laboratory of LBNL recently demonstrated production of 100 MeV electron beams with low energy spread and low divergence from laser wakefield acceleration. The radiation pressure of a 10 TW laser pulse guided over 10 diffraction ranges by a plasma density channel was used to drive an intense plasma wave (wakefield), producing acceleration gradients on the order of 100 GV/m in a mm-scale channel. Beam energy has now been increased from 100 to 1000 MeV by using a cm-scale guiding channel at lower density, driven by a 40TW laser, demonstrating the anticipated scaling to higher beam energies. Particle simulations indicate that the low energy spread beams were produced from self trapped electrons through the interplay of trapping, loading, and dephasing. Other experiments and simulations are also underway to control injection of particles into the wake, and hence improve beam quality and stability further

  5. Results from preliminary experiments of the 1 MeV 0.1 A D- project at CEA-Cadarache

    International Nuclear Information System (INIS)

    Simonin, A.; Fumelli, M.; Jequier, F.; Pamela, J.; Bucalossi, J.; Bottereau, J.M.; Brugnetti, R.

    1994-01-01

    A 1 MeV 0.1 A D - -beam acceleration experiment under preparation is described. It will study a simplified concept of negative ion beam electrostatic accelerator called SINGAP. Some critical HV components, like a large MV bushing or protection systems against the HV vacuum breakdowns will also be tested. The experiments reported here have been conducted during the preparatory phase of this MeV project. A negative ion source was developed and produced 1 A D - beams and j(D - )=12 mA/cm 2 beams. A new type of extraction grid was designed which traps almost 100% of the stray electrons extracted from the source plasma. A new emittance diagnostic has been successfully tested with 60-100 keV D - beams. A 1 MV 120 mA Haefely power supply has been moved from KfK, adapted and operated on a resistive load at the nominal operating characteristics. (author) 5 refs.; 6 figs

  6. Parity violation in polarized p-p scattering at 222 MEV

    International Nuclear Information System (INIS)

    Bandyopadhyay, D.; Birchall, J.; Campbell, J.; Davis, C.A.; Davison, N.E.; Page, S.A.; Ramsay, W.D.; Sekulovich, A.M.; Oers, W.T.H. van; Davis, C.A.; Healey, D.C.; Schmor, P.W.; Stinson, G.M.; Boyce, M.; Green, P.W.; Korkmaz, E.; Soukup, J.; Bowman, J.D.; Mischke, R.E.

    1989-01-01

    An experiment is in progess at TRIUMF to measure the parity-violating longitudinal analyzing power A z in polarizedp-p scattering at 222 MeV. Previous measurements at 15 and 45 MeV have determined the parity-mixed partial wave scattering amplitude to high precision. In contrast, only the ( 3 P 2 - 1 D 2 ) amplitude contributes to A z at 222 MeV. These two amplitudes yield complementary information on the underlying parity violating reaction mechanism. In a weak meson exchange model, the ( 3 P 2 - 1 D 2 ) amplitude is entirely due to rho meson exchange, and the present experiment affords a unique opportunity to measure the weak ρ-N coupling strength h ρ . At TRIUMF, a 500 nA beam of longitudinally polarized protons (p z ∼0.8) from the optically pumped polarized ion source will be scattered from a 20 cm liquid hydrogen target. A unique feature of this experiment is that A z will be measured in two different geometries (scattering and transmission mode) simultaneously, which will provide a crucial consistency check on the results. Monte Carlo simulations have confirmed that d.c. ionization chambers used to collect the transmitted and scattered protons in the two simultaneous measurements will achieve comparable statistical accuracies in the ∼ 300 hour counting time proposed for the experiment. High precision monitoring devices are being constructed and tested at TRIUMF to monitor changes in beam properties, such as beam position and residual transverse polarization, that can contribute to systematic errors in the parity violation measurements. The present status of the detector developments and systematic error controls will be discussed

  7. Design and performance of a 3.3-MeV linear induction accelerator (LIA)

    International Nuclear Information System (INIS)

    Cheng Nianan; Zhang Shouyun; Tao Zucong

    1992-01-01

    A 3.3-MeV linear induction accelerator (LIA) has been designed and constructed at the China Academy of Engineering Physics. The parameters of 3.4 MeV, 2 kA, 80 ns and 1 x 10 4 A/(rad.cm) 2 have been achieved. It has been used for SG-1 FEL experiments. The accelerator is mounted on a movable frame so that , after moving 3 m transversely, it can be assembled with more modules into a 10-MeV LIA. The authors summarize the physics and engineering aspects of the LIA facility and describe the measuring means of characters for the beam

  8. Calibration of a dePangher long counter from 2 keV to 19 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Slaughter, D R; Rueppel, D W [California Univ., Livermore (USA). Lawrence Livermore Lab.

    1977-09-01

    The authors have measured the sensitivity of a dePangher precision long counter (PLC) relative to /sup 7/Li(p,n), T(p,n), and T(d,n) differential cross sections over the neutron energy range 10 keV-19 MeV. Absolute sensitivity at 2 keV is also measured, using a scandium filtered beam at a reactor. Results obtained with errors in the range 5-30% are consistent with the assumption of a nearly constant sensitivity over the range 2 keV-6 MeV, but exhibit a reduction above 12 MeV.

  9. The IFMIF-EVEDA accelerator beam dump design

    International Nuclear Information System (INIS)

    Iglesias, D.; Arranz, F.; Arroyo, J.M.; Barrera, G.; Branas, B.; Casal, N.; Garcia, M.; Lopez, D.; Martinez, J.I.; Mayoral, A.; Ogando, F.; Parro, M.; Oliver, C.; Rapisarda, D.; Sanz, J.; Sauvan, P.; Ibarra, A.

    2011-01-01

    The IFMIF-EVEDA accelerator will be a 9 MeV, 125 mA cw deuteron accelerator prototype for verifying the validity of the 40 MeV accelerator design for IFMIF. A beam dump designed for maximum power of 1.12 MW will be used to stop the beam at the accelerator exit. The conceptual design for the IFMIF-EVEDA accelerator beam dump is based on a conical beam stop made of OFE copper. The cooling system uses an axial high velocity flow of water pressurized up to 3.4 x 10 5 Pa to avoid boiling. The design has been shown to be compliant with ASME mechanical design rules under nominal full power conditions. A sensitivity analysis has been performed to take into account the possible margin on the beam properties at the beam dump entrance. This analysis together with the study of the maintenance issues and the mounting and dismounting operations has led to the complete design definition.

  10. Caring for the Jehovah's Witness Parturient.

    Science.gov (United States)

    Mason, C LaToya; Tran, Connie K

    2015-12-01

    Caring for the Jehovah's Witness parturient is a complex task that presents a number of ethical, medical, and legal concerns because many Jehovah's Witnesses refuse allogeneic blood transfusion. Childbirth and its surrounding events may be associated with significant blood loss. Given their significant role in the intraoperative administration of blood products, anesthesia providers should be familiar with factors that must be considered in the perioperative care of Jehovah's Witness parturients. Several pharmacologic therapies, anesthetic techniques, and operative interventions aimed at blood conservation may be useful in the care of such patients. Aside from their refusal of transfusion, each Witness makes a personal decision on the acceptability of derivatives of plasma or cellular blood components and autologous blood management. Therefore, the patient-physician relationship must ensure that the individual patient's desires are accurately communicated, respected, and documented in the patient's medical record. The Perioperative Surgical Home model is appropriate for use in caring for Jehovah's Witness patients because it allows for the early and continuing coordination of care and communication between the patient and a multidisciplinary team. In this article, we present a focused review of concepts important to the provision of anesthetic care of parturients who are Jehovah's Witnesses and introduce an algorithmic perioperative approach that may be applied to the care of the Jehovah's Witness parturient undergoing an operative procedure.

  11. Neutron-neutron quasifree scattering in nd breakup at 10 MeV

    Science.gov (United States)

    Malone, R. C.; Crowe, B.; Crowell, A. S.; Cumberbatch, L. C.; Esterline, J. H.; Fallin, B. A.; Friesen, F. Q. L.; Han, Z.; Howell, C. R.; Markoff, D.; Ticehurst, D.; Tornow, W.; Witała, H.

    2016-03-01

    The neutron-deuteron (nd) breakup reaction provides a rich environment for testing theoretical models of the neutron-neutron (nn) interaction. Current theoretical predictions based on rigorous ab-initio calculations agree well with most experimental data for this system, but there remain a few notable discrepancies. The cross section for nn quasifree (QFS) scattering is one such anomaly. Two recent experiments reported cross sections for this particular nd breakup configuration that exceed theoretical calculations by almost 20% at incident neutron energies of 26 and 25 MeV [1, 2]. The theoretical values can be brought into agreement with these results by increasing the strength of the 1S0 nn potential matrix element by roughly 10%. However, this modification of the nn effective range parameter and/or the 1S0 scattering length causes substantial charge-symmetry breaking in the nucleon-nucleon force and suggests the possibility of a weakly bound di-neutron state [3]. We are conducting new measurements of the cross section for nn QFS in nd breakup. The measurements are performed at incident neutron beam energies below 20 MeV. The neutron beam is produced via the 2H(d, n)3He reaction. The target is a deuterated plastic cylinder. Our measurements utilize time-of-flight techniques with a pulsed neutron beam and detection of the two emitted neutrons in coincidence. A description of our initial measurements at 10 MeV for a single scattering angle will be presented along with preliminary results. Also, plans for measurements at other energies with broad angular coverage will be discussed.

  12. Observations on late effects in mice exposed to 400 MeV neutrons

    CERN Document Server

    Covelli, V; Bassani, B; Baarli, Johan; Bianchi, M; Metalli, P; Covelli, V; Di Paola, M; Bassani, B; Baarli, J no 2; Bianchi, M no 2; Metalli, P

    1976-01-01

    Life-long observations on mortality and pathology at death were carried out on groups of mice irradiated with 250 kV X-rays or exposed to a 400 MeV neutron beam, both directly and after attenuation corresponding to the maximum dose build-up region, at comparable dose-rates. Doses up to 84 rad of 400 MeV neutrons and up to 200 rad of X-rays showed no effect on the longevity of the animals, which suggests an upper limit to the r.b.e. for life-shortening of approximately 2·5. Similar conclusions were drawn from the data on all types of leukemias. For all other neoplasms, the age-specific death-rate showed a similar shortening of the latency times for groups of mice irradiated with 0–84 rad of 400 MeV direct neutrons and 0–400 rad of X-rays, also suggesting an upper limit to the r.b.e. slightly higher than that previously indicated for life-shortening. No definite effect was observed after exposure to the attenuated neutron beam at the doses used in these experiments.

  13. On the absorbed dose determination method in high energy electrons beams

    International Nuclear Information System (INIS)

    Scarlat, F.; Scarisoreanu, A.; Oane, M.; Mitru, E.; Avadanei, C.

    2008-01-01

    The absorbed dose determination method in water for electron beams with energies in the range from 1 MeV to 50 MeV is presented herein. The dosimetry equipment for measurements is composed of an UNIDOS.PTW electrometer and different ionization chambers calibrated in air kerma in a Co 60 beam. Starting from the code of practice for high energy electron beams, this paper describes the method adopted by the secondary standard dosimetry laboratory (SSDL) in NILPRP - Bucharest

  14. Two-body photodisintegration of [sup 3]He between 200 and 800 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Isbert, V. (SPhN-DAPNIA, C.E.N. Saclay, 91191 Gif sur Yvette (France)); Audit, G. (SPhN-DAPNIA, C.E.N. Saclay, 91191 Gif sur Yvette (France)); D' Hose, N. (SPhN-DAPNIA, C.E.N. Saclay, 91191 Gif sur Yvette (France)); Kerhoas, S. (SPhN-DAPNIA, C.E.N. Saclay, 91191 Gif sur Yvette (France)); MacCormick, M. (SPhN-DAPNIA, C.E.N. Saclay, 91191 Gif sur Yvette (France)); Tamas, G. (SPhN-DAPNIA, C.E.N. Saclay, 91191 Gif sur Yvette (France)); Wallace, P.A. (SPhN-DAPNIA, C.E.N. Saclay, 91191 Gif sur Yvette (France)); Altieri, S. (INFN-Sezione di Pavia, via Bassi 6, 27100 Pavia (Italy) Dipartimento di Fisica Nucleare e Teorica, Universita degli Studi di Pavia, via Bassi 6, 27100 Pavia (Italy)); Braghieri, A. (INFN-Sezione di Pavia, via Bassi 6, 27100 Pavia (Italy) Dipartimento di Fisica Nucleare e Teorica, Universita degli Studi di Pavia, via Bassi 6, 27100 Pavia (Italy)); Pedroni, P. (INFN-Sezione di Pavia, via Bassi 6, 27100 Pavia (Italy)); Pinelli, T. (INFN-Sezione di Pavia, via Bassi 6; DAPHNE Collaboration

    1994-10-10

    Differential cross sections for the [sup 3]He([gamma],pd) reaction at photon energies between 200 and 800 MeV at all proton c.m. angles between 35[sup circle] and 145[sup circle] have been measured using the tagged photon beam facility of the 855 MeV MAMI accelerator in Mainz. Reaction products were detected using the large acceptance detector DAPHNE. The results confirm the rapid decrease of forward-angle cross sections with increasing E[sub [gamma

  15. Dosimetric characteristics of a MOSFET dosimeter for clinical electron beams.

    Science.gov (United States)

    Manigandan, D; Bharanidharan, G; Aruna, P; Devan, K; Elangovan, D; Patil, Vikram; Tamilarasan, R; Vasanthan, S; Ganesan, S

    2009-09-01

    The fundamental dosimetric characteristics of commercially available metal oxide semiconductor field effect transistor (MOSFET) detectors were studied for clinical electron beam irradiations. MOSFET showed excellent linearity against doses measured using an ion chamber in the dose range of 20-630cGy. MOSFET reproducibility is better at high doses compared to low doses. The output factors measured with the MOSFET were within +/-3% when compared with those measured with a parallel plate chamber. From 4 to 12MeV, MOSFETs showed a large angular dependence in the tilt directions and less in the axial directions. MOSFETs do not show any dose-rate dependence between 100 and 600MU/min. However, MOSFETs have shown under-response when the dose per pulse of the beam is decreased. No measurable effect in MOSFET response was observed in the temperature range of 23-40 degrees C. The energy dependence of a MOSFET dosimeter was within +/-3.0% for 6-18MeV electron beams and 5.5% for 4MeV ones. This study shows that MOSFET detectors are suitable for dosimetry of electron beams in the energy range of 4-18MeV.

  16. Dual scattering foil design for poly-energetic electron beams

    International Nuclear Information System (INIS)

    Kainz, K K; Antolak, J A; Almond, P R; Bloch, C D; Hogstrom, K R

    2005-01-01

    The laser wakefield acceleration (LWFA) mechanism can accelerate electrons to energies within the 6-20 MeV range desired for therapy application. However, the energy spectrum of LWFA-generated electrons is broad, on the order of tens of MeV. Using existing laser technology, the therapeutic beam might require a significant energy spread to achieve clinically acceptable dose rates. The purpose of this work was to test the assumption that a scattering foil system designed for a mono-energetic beam would be suitable for a poly-energetic beam with a significant energy spread. Dual scattering foil systems were designed for mono-energetic beams using an existing analytical formalism based on Gaussian multiple-Coulomb scattering theory. The design criterion was to create a flat beam that would be suitable for fields up to 25 x 25 cm 2 at 100 cm from the primary scattering foil. Radial planar fluence profiles for poly-energetic beams with energy spreads ranging from 0.5 MeV to 6.5 MeV were calculated using two methods: (a) analytically by summing beam profiles for a range of mono-energetic beams through the scattering foil system, and (b) by Monte Carlo using the EGS/BEAM code. The analytic calculations facilitated fine adjustments to the foil design, and the Monte Carlo calculations enabled us to verify the results of the analytic calculation and to determine the phase-space characteristics of the broadened beam. Results showed that the flatness of the scattered beam is fairly insensitive to the width of the input energy spectrum. Also, results showed that dose calculated by the analytical and Monte Carlo methods agreed very well in the central portion of the beam. Outside the useable field area, the differences between the analytical and Monte Carlo results were small but significant, possibly due to the small angle approximation. However, these did not affect the conclusion that a scattering foil system designed for a mono-energetic beam will be suitable for a poly

  17. Three-fold increase of M1 strength in 40Ar at 10 MeV excitation energy

    Science.gov (United States)

    Tornow, Werner; Finch, Sean; Krishichayan, Fnu; Tonchev, Anton

    2017-09-01

    We reexamined the excitation energy region of 40Ar around 9.8 MeV with the goal of determining the known M1 strength located at 9.76 MeV more accurately. The physics motivation was based on the fact that i) the neutrino-nucleus interaction cross section is proportional to the M1 strength of a nucleus, ii) DUNE, the Deep Underground Neutrino Experiment at SURF will be using liquid argon as detector medium, iii) the energy spectrum of supernova neutrinos is peaked at approximately 10 MeV. Mono-energetic and linearly polarized photons of 9.88 MeV were produced via Compton backscattering of 548 nm FEL photons from 543 MeV electrons at the High-Intensity γ-ray Source (HI γS) facility at TUNL. The 1.25 cm diameter photon beam with energy spread of 300 keV (FWHM) interacted with argon gas contained in a high-pressure cell. The cell was viewed with HPGe detectors placed at 90o relative to the incident photon beam in the horizontal and vertical planes to distinguish between E1 and M1 de-excitation γ-rays. Our re-measurement provided an increase in M1 strength by a factor of approximately 3, mostly due to the discovery that the known level in 40Ar at 9.84 MeV is of M1 character and not of E1 character, as previously thought. In addition to the already known M1 state at 9.76 MeV, we observed weaker M1 states at 9.70, 9.81, 9.87, and 9.89 MeV.

  18. Effects produced in GaAs by MeV ion bombardment

    International Nuclear Information System (INIS)

    Wie, C.R.

    1985-01-01

    The first part of this thesis presents work performed on the ionizing energy beam induced adhesion enhancement of thin (approx.500 A) Au films on GaAs substrates. The ionizing beam, employed in the present thesis, is the MeV ions (i.e., 16 O, 19 F, and 35 Cl), with energies between 1 and 20 MeV. Using the Scratch test for adhesion measurement, and ESCA for chemical analysis of the film substrate interface, the native oxide layer at the interface is shown to play an important role in the adhesion enhancement by the ionizing radiation. A model is discussed that explains the experimental data on the dependence of adhesion enhancement on the energy which was deposited into electronic processes at the interface. The second part of the thesis presents research results on the radiation damage in GaAs crystals produced by MeV ions. Lattice parameter dilatation in the surface layers of the GaAs crystals becomes saturated after a high dose bombardment at room temperature. The strain produced by nuclear collisions is shown to relax partially due to electronic excitation (with a functional dependence on the nuclear and electronic stopping power of bombarding ions. Data on the GaAs and GaP crystals suggest that low temperature recovery stage defects produce major crystal distortion

  19. A novel source of MeV positron bunches driven by energetic protons for PAS application

    Energy Technology Data Exchange (ETDEWEB)

    Tan, Zongquan, E-mail: tqq1123@mail.ustc.edu.cn [State Key Laboratory of Particle Detection and Electronics, University of Science and Technology of China, Hefei, Anhui 230026 (China); Department of Modern Physics, University of Science and Technology of China, Hefei, Anhui 230026 (China); Xu, Wenzhen; Liu, Yanfen; Xiao, Ran; Kong, Wei [State Key Laboratory of Particle Detection and Electronics, University of Science and Technology of China, Hefei, Anhui 230026 (China); Department of Modern Physics, University of Science and Technology of China, Hefei, Anhui 230026 (China); Ye, Bangjiao, E-mail: bjye@ustc.edu.cn [State Key Laboratory of Particle Detection and Electronics, University of Science and Technology of China, Hefei, Anhui 230026 (China); Department of Modern Physics, University of Science and Technology of China, Hefei, Anhui 230026 (China)

    2014-11-01

    This paper proposes a novel methodology of MeV positrons generation for PAS application. Feasibility of this proposal analyzed by G4Beamline and Transport have shown reasonable success. Using 2 Hz, 1.6 GeV, 100 ns and 1.5 μC/bunch proton bunches for bombarding a graphite target, about 100 ns e{sup +} bunches are generated. Quasi-monochromatic positrons in the range of 1–10 MeV included in these bunches have a flux of >10{sup 7}/s, peak brightness of 10{sup 14}/s. A magnetic-confinement beamline is utilized to transport the positrons and a “Fast Beam Chopper” is unprecedentedly extended to chop those relativistic bunches. The positron beam can be finally characterized by the energy range of 1–10 MeV and bunch width from one hundred ps up to 1 ns. Such ultrashort bunches can be useful in tomography-type positron annihilation spectroscopy (PAS) as well as other applications.

  20. A novel source of MeV positron bunches driven by energetic protons for PAS application

    Science.gov (United States)

    Tan, Zongquan; Xu, Wenzhen; Liu, Yanfen; Xiao, Ran; Kong, Wei; Ye, Bangjiao

    2014-11-01

    This paper proposes a novel methodology of MeV positrons generation for PAS application. Feasibility of this proposal analyzed by G4Beamline and Transport have shown reasonable success. Using 2 Hz, 1.6 GeV, 100 ns and 1.5 μC/bunch proton bunches for bombarding a graphite target, about 100 ns e+ bunches are generated. Quasi-monochromatic positrons in the range of 1-10 MeV included in these bunches have a flux of >107/s, peak brightness of 1014/s. A magnetic-confinement beamline is utilized to transport the positrons and a "Fast Beam Chopper" is unprecedentedly extended to chop those relativistic bunches. The positron beam can be finally characterized by the energy range of 1-10 MeV and bunch width from one hundred ps up to 1 ns. Such ultrashort bunches can be useful in tomography-type positron annihilation spectroscopy (PAS) as well as other applications.

  1. Calculation of channels for forming and transport of medical proton beams at the JINR phasotron

    International Nuclear Information System (INIS)

    Kuz'min, E.S.; Mirokhin, I.V.; Molokanov, A.G.; Obukhov, Yu.L.; Savchenko, O.V.

    1984-01-01

    Results of numerical simulation of shaping and transporting processes of therapeutic proton beams with a modified Bragg curve at the JINR phasotron are presented. The mean energy of proton beams are about 100, 130 and 200 MeV. To provide the flat-topped depth-dose distributions with a steep back slope, the method of shaping with a necessary energy spectrum from a nonmonoenergetic beam is used. It is shown by the calculations that it is possible to choose such modes of the channel operation at which clinical-physical requirements to the parameters of medical proton beams are satisfied. Extensions of flat-tops of dose peaks are 1.3 g/cm 2 , 1.7 g/cm 2 and 3.5 g/cm 2 for the 100 MeV, 130 MeV and 200 MeV beam energies, respectively. Dose rate in the peaks of modified distributions are not less than 100 rad per minute

  2. Electron beam processing of materials-R and D and industrial utilization

    International Nuclear Information System (INIS)

    Sarma, K.S.S.

    2005-01-01

    The early sixties witnessed the beginning of Electron Beam (EB) processing of materials using high-energy electrons and has emerged as a well established technology, presently being adapted by the industry. The process and the processed materials showed definite and distinct advantages/characteristics over the available conventional methods. Even though the commercial exploitation started initially in polymer modifications for better (and suitable) performance through polymerization, cross-linking, degradation and grafting, the processing fields are now diverged to sterilization of health care, food irradiation, controlled defects in semiconductor devices and semi and/or precious stones, waste water/flue gas treatment etc. The availability of electron accelerators that operate as per the requirement of the industrial needs, easy maintenance, expertise availability etc brought the EB processing industry into a multi dollar business world wide. In USA and Japan there are more than 1200 accelerators currently operative in automobile tire, wire and cable and heat shrinkable industry. Output beam powers exceeding 400 kW with electron energy ranging from few hundred keV up to 10 MeV are made available to the industry. In BARC EB processing started with the 2MeV/20 kW electron accelerator and suitable processing techniques have been developed for applications like polymer cross linking (heat resistant LDPE O-rings, wire and cable insulation), color enhancement in precious stones (diamonds) on industrial scale and polymer curing, grafting, degradation on R and D/pilot scale. The commercial success of the process enabled the private cable industry to set up accelerators at their factories. On research and development front, the accelerator is being utilized to develop new polymer blends for high temperature applications, for solid and liquid waste treatment, polypropylene grafting experiments for uranium extraction from sea water, surface curing etc. This paper gives

  3. Operational characteristics of a 100-mA, 2-MeV radio-frequency quadrupole

    International Nuclear Information System (INIS)

    Johnson, K.F.; Cottingame, W.B.; Bolme, G.O.; Fortgang, C.M.; Ingalls, W.B.; Marquardt, J.; Rusthoi, D.P.; Sander, O.R.; Smith, M.; Worth, G.T.

    1993-01-01

    A 100-mA, 2.07-MeV Radio-Frequency Quadrupole (RFQ III) has been commissioned and operated routinely on the Accelerator Test Stand (ATS) [1] at Los Alamos National Laboratory. To characterize the RFQ output beam dynamics, measurements were made of the beam transmission and of the transverse and longitudinal phase-space distributions. Data were taken for different RFQ III operating conditions and compared to simulations

  4. Mechanical design of beam extractor system for cyclotron proton 13 MeV

    International Nuclear Information System (INIS)

    Ihwanul Aziz; Widdi Usada

    2012-01-01

    Mechanical design of beam extractor system for 13 MeV proton cyclotron has been carried out. In cyclotron there are two extractor systems, the first is electrostatic deflector system, and the second is stripper system. This stripper serves to change negative charged of hydrogen ions to become positive charged hydrogen ions (protons). In proton cyclotron, the carbon foil is used as a stripper. Mechanical extractor system consists of a carbon foil holder and a driver system to control the position of foil holder and to change the foil. The driver system consists of a stepper motor extractor, a feed-through, a gear, a shaft, and a buffer. After some calculation the obtained component data as the foil follow holder is made of aluminum has total length of 12.25 mm, total width of 10 mm and the total thickness of 2.5 mm, while the length of each extractor arm is made of aluminum 90 mm, width is 30 mm, its height is 10 mm , the total volume is 7,392 x 10-5 and a mass of 0.1995 kg. Extractor drive system includes a stepper motor having a maximum of 4 lb-ft of torque, feed through, gear, shaft, and a buffer. Required torque is 0.16 Nm or 0.12 lb-ft diameter shaft to support the extractor arm is 29 mm. Bolt fastener for the buffer is a type of metric M6 bolt, so that the used seals viton O-ring with seal diameter of 6 mm and DN 40 CF flange. (author)

  5. Shielding measurements for a 230 MeV proton beam

    International Nuclear Information System (INIS)

    Siebers, J.V.

    1990-01-01

    Energetic secondary neutrons produced as protons interact with accelerator components and patients dominate the radiation shielding environment for proton radiotherapy facilities. Due to the scarcity of data describing neutron production, attenuation, absorbed dose, and dose equivalent values, these parameters were measured for 230 MeV proton bombardment of stopping length Al, Fe, and Pb targets at emission angles of 0 degree, 22 degree, 45 degree, and 90 degree in a thick concrete shield. Low pressure tissue-equivalent proportional counters with volumes ranging from 1 cm 3 to 1000 cm 3 were used to obtain microdosimetric spectra from which absorbed dose and radiation quality are deduced. Does equivalent values and attenuation lengths determined at depth in the shield were found to vary sharply with angle, but were found to be independent of target material. Neutron dose and radiation length values are compared with Monte Carlo neutron transport calculations performed using the Los Alamos High Energy Transport Code (LAHET). Calculations used 230 MeV protons incident upon an Fe target in a shielding geometry similar to that used in the experiment. LAHET calculations overestimated measured attenuation values at 0 degree, 22 degree, and 45 degree, yet correctly predicted the attenuation length at 90 degree. Comparison of the mean radiation quality estimated with the Monte Carlo calculations with measurements suggest that neutron quality factors should be increased by a factor of 1.4. These results are useful for the shielding design of new facilities as well as for testing neutron production and transport calculations

  6. Escaping 1 MeV tritons in TFTR

    International Nuclear Information System (INIS)

    Zweben, S.J.; Strachan, J.D.; Boivin, R.; Cavallo, A.; Fredrickson, E.D.; McGuire, K.; Mynick, H.E.; White, R.B.

    1989-01-01

    1 MeV tritons created by D-D reactions can simulate the 'single-particle' behavior expected with 3.5 MeV D-T alphas, since the gyroradii and slowing-down of these two particles are similar. This paper describes measurements of the flux of escaping 1 MeV tritons from the TFTR plasma during high power D 0 →D neutral beam injection, and shows that in most cases the observed triton loss is consistent with the classical (single-particle) first-orbit loss model. In this model tritons are lost if their first orbit intersects the wall due to their large banana width, while almost all tritons confined on their first orbit should stay confined until thermalized. The triton detectors are ZnS(Ag) scintillator screens housed in light-tight boxes located just outside the plasma boundary at the bottom of the TFTR vessel. They are particle 'pinhole' cameras which can resolve the triton flux vs. pitch angle (to ±5 o ), energy (to ±50 %), and time (to <20 μsec). The 2-D images of triton flux onto these scintillators are optically coupled to either an intensified TV camera or to photomultiplyer tubes for fast time resolution. The soft x-ray background in an earlier prototype has been eliminated. Although there are presently 8 such detectors in TFTR, this paper discusses results from only the detector located just below the vessel center (R=259 cm, r=102 cm). Note that the '1 MeV triton' signal discussed below also has about a 30 % contribution from 3 MeV protons; however, since these two particles have identical gyroradii they should behave alike. 5 refs., 5 figs

  7. Comparison of film measurements and Monte Carlo simulations of dose delivered with very high-energy electron beams in a polystyrene phantom.

    Science.gov (United States)

    Bazalova-Carter, Magdalena; Liu, Michael; Palma, Bianey; Dunning, Michael; McCormick, Doug; Hemsing, Erik; Nelson, Janice; Jobe, Keith; Colby, Eric; Koong, Albert C; Tantawi, Sami; Dolgashev, Valery; Maxim, Peter G; Loo, Billy W

    2015-04-01

    To measure radiation dose in a water-equivalent medium from very high-energy electron (VHEE) beams and make comparisons to Monte Carlo (MC) simulation results. Dose in a polystyrene phantom delivered by an experimental VHEE beam line was measured with Gafchromic films for three 50 MeV and two 70 MeV Gaussian beams of 4.0-6.9 mm FWHM and compared to corresponding MC-simulated dose distributions. MC dose in the polystyrene phantom was calculated with the EGSnrc/BEAMnrc and DOSXYZnrc codes based on the experimental setup. Additionally, the effect of 2% beam energy measurement uncertainty and possible non-zero beam angular spread on MC dose distributions was evaluated. MC simulated percentage depth dose (PDD) curves agreed with measurements within 4% for all beam sizes at both 50 and 70 MeV VHEE beams. Central axis PDD at 8 cm depth ranged from 14% to 19% for the 5.4-6.9 mm 50 MeV beams and it ranged from 14% to 18% for the 4.0-4.5 mm 70 MeV beams. MC simulated relative beam profiles of regularly shaped Gaussian beams evaluated at depths of 0.64 to 7.46 cm agreed with measurements to within 5%. A 2% beam energy uncertainty and 0.286° beam angular spread corresponded to a maximum 3.0% and 3.8% difference in depth dose curves of the 50 and 70 MeV electron beams, respectively. Absolute dose differences between MC simulations and film measurements of regularly shaped Gaussian beams were between 10% and 42%. The authors demonstrate that relative dose distributions for VHEE beams of 50-70 MeV can be measured with Gafchromic films and modeled with Monte Carlo simulations to an accuracy of 5%. The reported absolute dose differences likely caused by imperfect beam steering and subsequent charge loss revealed the importance of accurate VHEE beam control and diagnostics.

  8. Comparison of film measurements and Monte Carlo simulations of dose delivered with very high-energy electron beams in a polystyrene phantom

    Energy Technology Data Exchange (ETDEWEB)

    Bazalova-Carter, Magdalena; Liu, Michael; Palma, Bianey; Koong, Albert C.; Maxim, Peter G., E-mail: Peter.Maxim@Stanford.edu, E-mail: BWLoo@Stanford.edu; Loo, Billy W., E-mail: Peter.Maxim@Stanford.edu, E-mail: BWLoo@Stanford.edu [Department of Radiation Oncology, Stanford University, Stanford, California 94305-5847 (United States); Dunning, Michael; McCormick, Doug; Hemsing, Erik; Nelson, Janice; Jobe, Keith; Colby, Eric; Tantawi, Sami; Dolgashev, Valery [SLAC National Accelerator Laboratory, Menlo Park, California 94025 (United States)

    2015-04-15

    Purpose: To measure radiation dose in a water-equivalent medium from very high-energy electron (VHEE) beams and make comparisons to Monte Carlo (MC) simulation results. Methods: Dose in a polystyrene phantom delivered by an experimental VHEE beam line was measured with Gafchromic films for three 50 MeV and two 70 MeV Gaussian beams of 4.0–6.9 mm FWHM and compared to corresponding MC-simulated dose distributions. MC dose in the polystyrene phantom was calculated with the EGSnrc/BEAMnrc and DOSXYZnrc codes based on the experimental setup. Additionally, the effect of 2% beam energy measurement uncertainty and possible non-zero beam angular spread on MC dose distributions was evaluated. Results: MC simulated percentage depth dose (PDD) curves agreed with measurements within 4% for all beam sizes at both 50 and 70 MeV VHEE beams. Central axis PDD at 8 cm depth ranged from 14% to 19% for the 5.4–6.9 mm 50 MeV beams and it ranged from 14% to 18% for the 4.0–4.5 mm 70 MeV beams. MC simulated relative beam profiles of regularly shaped Gaussian beams evaluated at depths of 0.64 to 7.46 cm agreed with measurements to within 5%. A 2% beam energy uncertainty and 0.286° beam angular spread corresponded to a maximum 3.0% and 3.8% difference in depth dose curves of the 50 and 70 MeV electron beams, respectively. Absolute dose differences between MC simulations and film measurements of regularly shaped Gaussian beams were between 10% and 42%. Conclusions: The authors demonstrate that relative dose distributions for VHEE beams of 50–70 MeV can be measured with Gafchromic films and modeled with Monte Carlo simulations to an accuracy of 5%. The reported absolute dose differences likely caused by imperfect beam steering and subsequent charge loss revealed the importance of accurate VHEE beam control and diagnostics.

  9. Experimental research on a double pulsed beam source

    International Nuclear Information System (INIS)

    Xia Liansheng; Zhang Linwen; Huang Ziping; Gao Feng; Shi Jinshui; Deng Jianjun

    2004-01-01

    A double pulsed beam generator is built based on 2 MeV linear induction accelerator (LIA) injector. The second power source and 8 inductive cells of the injector are divided into two groups and work alternatively. Electron energy of each beam is up to 1 MeV and the beam duration is 120 ns with adjustable pulse interval (from 200 ns to 800 ns). The voltage amplitude difference of the two pulses can be less than 2%. The electron beams are emitted from a velvet cathode in a vacuum diode. The beam currents are up to 3 kA, measured both by a Faraday cup in anode hole and by a shunt resistor at the rail of the LIA injector. This device can be used to study multi-pulse diode physics and emitting physics of different materials under multi-pulse mode. (author)

  10. Study of the reaction pp → π+d at 576 MeV

    International Nuclear Information System (INIS)

    Aebischer, D.; Favier, B.; Greeniaus, G.; Hess, R.; Junod, A.; Lechanoine, C.; Nikles, J.C.; Rapin, D.; Werren, D.W.

    1975-01-01

    A 576 MeV polarized proton beam has been used to study the pp → π + d reaction for small centre of mass π-production angles. The final state π and d were observed using a system of multiwire proportional chambers. The presence of a term in cos 4 thetasub(cm) for the differential cross-section has been tested. The left-right π production asymmetry for a transversely polarized beam has also been measured. (Auth.)

  11. Dosimetric evaluation of lead and tungsten eye shields in electron beam treatment

    International Nuclear Information System (INIS)

    Shiu, Almon S.; Tung, Samuel S.; Gastorf, Robert J.; Hogstrom, Kenneth R.; Morrison, William H.; Peters, Lester J.

    1996-01-01

    Purpose: The purpose of this study is to report that commercially available eye shields (designed for orthovoltage x-rays) are inadequate to protect the ocular structures from penetrating electrons for electron beam energies equal to or greater than 6 MeV. Therefore, a prototype medium size tungsten eye shield was designed and fabricated. The advantages of the tungsten eye shield over lead are discussed. Methods and Materials: Electron beams (6-9 MeV) are often used to irradiate eyelid tumors to curative doses. Eye shields can be placed under the eyelids to protect the globe. Film and thermoluminescent dosimeters (TLDs) were used within a specially constructed polystyrene eye phantom to determine the effectiveness of various commercially available internal eye shields (designed for orthovoltage x-rays). The same procedures were used to evaluate a prototype medium size tungsten eye shield (2.8 mm thick), which was designed and fabricated for protection of the globe from penetrating electrons for electron beam energy equal to 9 MeV. A mini-TLD was used to measure the dose enhancement due to electrons backscattered off the tungsten eye shield, both with or without a dental acrylic coating that is required to reduce discomfort, permit sterilization of the shield, and reduce the dose contribution from backscattered electrons. Results: Transmission of a 6 MeV electron beam through a 1.7 mm thick lead eye shield was found to be 50% on the surface (cornea) of the phantom and 27% at a depth of 6 mm (lens). The thickness of lead required to stop 6-9 MeV electron beams is impractical. In place of lead, a prototype medium size tungsten eye shield was made. For 6 to 9 MeV electrons, the doses measured on the surface (cornea) and at 6 mm (lens) and 21 mm (retina) depths were all less than 5% of the maximum dose of the open field (4 x 4 cm). Electrons backscattered off a tungsten eye shield without acrylic coating increased the lid dose from 85 to 123% at 6 MeV and 87 to 119% at

  12. 6 MeV RF Linac for cargo scanning and industrial radiography

    International Nuclear Information System (INIS)

    2017-01-01

    RF Linac-based X-ray sources are very widely used for cargo-scanning and industrial X-ray radiography applications. A 6 MeV on-axis coupled-cavity S-band RF linac has been designed, developed and tested successfully at Electron Beam Centre, Navi Mumbai. This facility falls under the purview of BARC Safety Council, which has conducted safety reviews and awarded regulatory clearances for the operation of the linac system. This paper outlines the salient features of the 6 MeV linac, its safety aspects and test results. A brief history of regulatory aspects is also presented

  13. Binary codes storage and data encryption in substrates with single proton beam writing technology

    International Nuclear Information System (INIS)

    Zhang Jun; Zhan Furu; Hu Zhiwen; Chen Lianyun; Yu Zengliang

    2006-01-01

    It has been demonstrated that characters can be written by proton beams in various materials. In contributing to the rapid development of proton beam writing technology, we introduce a new method for binary code storage and data encryption by writing binary codes of characters (BCC) in substrates with single proton beam writing technology. In this study, two kinds of BCC (ASCII BCC and long bit encrypted BCC) were written in CR-39 by a 2.6 MeV single proton beam. Our results show that in comparison to directly writing character shapes, writing ASCII BCC turned out to be about six times faster and required about one fourth the area in substrates. The approach of writing long bit encrypted BCC by single proton beams supports preserving confidential information in substrates. Additionally, binary codes fabricated by MeV single proton beams in substrates are more robust than those formed by lasers, since MeV single proton beams can make much deeper pits in the substrates

  14. Nuclear collisions at several tens of MeV per nucleus

    International Nuclear Information System (INIS)

    Randrup, J.

    1979-10-01

    Nuclear beams with energies of several tens of MeV per nucleon will soon be available at a number of research centers around the world. Such beams offer a tool for probing new aspects of nuclear structure and dynamics. As the energy is raised models and concepts developed for the relatively well studied lower energy domain will be pressed to their limits and are likely to grow obsolete as novel phenomena enter the scene. The theory of ordinary damped collisions is considered; the testing of such theories is one important aspect of the research with higher beam energies. Another is the search for truly novel phenomena, and some more speculative material on that aspect are given. 15 references

  15. Nuclear collisions at several tens of MeV per nucleus

    Energy Technology Data Exchange (ETDEWEB)

    Randrup, J.

    1979-10-01

    Nuclear beams with energies of several tens of MeV per nucleon will soon be available at a number of research centers around the world. Such beams offer a tool for probing new aspects of nuclear structure and dynamics. As the energy is raised models and concepts developed for the relatively well studied lower energy domain will be pressed to their limits and are likely to grow obsolete as novel phenomena enter the scene. The theory of ordinary damped collisions is considered; the testing of such theories is one important aspect of the research with higher beam energies. Another is the search for truly novel phenomena, and some more speculative material on that aspect are given. 15 references.

  16. Charged particle beams for radiobiology at RARAF

    International Nuclear Information System (INIS)

    Colvett, R.D.; Rohrig, N.; Marino, S.A.

    1977-01-01

    (1) The extent to which the internal structure of a molecule might affect the separation of its constituent atoms after the molecule dissociates was investigated. Scattered intensity vs. lateral distance is shown (at 46 cm) for beams of 1.25-MeV monatomic deuterons, 2.5-MeV diatomic deuterons, and 3.75-MeV triatomic deuterons. It was found that the three species of ions have essentially indistinguishable scattering parameters; i.e., molecular effects are negligible. (2) Representative LET spectra are shown for deuterons of 2.2, 1.9, and 1.7 MeV and 3 He of 6.2 MeV. 3 figures

  17. Generation of mega-electron-volt electron beams by an ultrafast intense laser pulse

    International Nuclear Information System (INIS)

    Wang Xiaofang; Saleh, Ned; Krishnan, Mohan; Wang Haiwen; Backus, Sterling; Murnane, Margaret; Kapteyn, Henry; Umstadter, Donald; Wang Quandong; Shen Baifei

    2003-01-01

    Mega-electron-volt (MeV) electron emission from the interaction of an ultrafast (τ∼29 fs), intense (>10 18 W/cm 2 ) laser pulse with underdense plasmas has been studied. A beam of MeV electrons with a divergence angle as small as 1 deg. is observed in the forward direction, which is correlated with relativistic filamentation of the laser pulse in plasmas. A novel net-energy-gain mechanism is proposed for electron acceleration resulting from the relativistic filamentation and beam breakup. These results suggest an approach for generating a beam of femtosecond, MeV electrons at a kilohertz repetition rate with a compact ultrafast intense laser system

  18. Design of a beam dump for the IFMIF-EVEDA accelerator

    International Nuclear Information System (INIS)

    Branas, B.; Iglesias, D.; Arranz, F.; Barrera, G.; Casal, N.; Garcia, M.; Gomez, J.; Lopez, D.; Martinez, J.I.; Martin-Fuertes, F.; Ogando, F.; Oliver, C.; Sanz, J.; Sauvan, P.; Ibarra, A.

    2009-01-01

    The IFMIF-EVEDA accelerator will be a 9 MeV, 125 mA cw deuteron accelerator prototype for verifying the validity of the accelerator design for IFMIF. A beam stop will be used for the RFQ and DTL commissioning as well as for the EVEDA accelerator tests. Therefore, this component must be designed to stop 5 MeV and 9 MeV deuteron beams with a maximum power of 1.13 MW. The first step of the design is the beam-facing material selection. The criteria used for this selection are low neutron production, low activation and good thermomechanical behavior. In this paper, the mechanical analysis and radioprotection calculations that have led to the choice of the main beam dump parameters will be described. The present design is based on a conical beam stop (2.5 m length, 30 cm diameter, and 3.5 mm thickness) made of copper plus a cylindrical 0.5 m long beam scraper. The cooling system is based on an axial high velocity flow of water. This design is compliant with the mechanical design rules during full power stationary operation of the accelerator. The radioprotection calculations performed demonstrate that, with an adequate local shielding, doses during beam on/off phases are below the limits.

  19. 20 CFR 258.2 - Witnesses.

    Science.gov (United States)

    2010-04-01

    ... 20 Employees' Benefits 1 2010-04-01 2010-04-01 false Witnesses. 258.2 Section 258.2 Employees' Benefits RAILROAD RETIREMENT BOARD REGULATIONS UNDER THE RAILROAD RETIREMENT ACT HEARINGS BEFORE THE BOARD... a delegation of authority to such examiner to require and compel the attendance of witnesses and the...

  20. 29 CFR 1921.18 - Witnesses and fees.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 7 2010-07-01 2010-07-01 false Witnesses and fees. 1921.18 Section 1921.18 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR... WORKERS' COMPENSATION ACT Miscellaneous § 1921.18 Witnesses and fees. Witnesses subpoenaed by any party...

  1. Commercial cyclotrons. Part I: Commercial cyclotrons in the energy range 10 30 MeV for isotope production

    Science.gov (United States)

    Papash, A. I.; Alenitsky, Yu. G.

    2008-07-01

    A survey of commercial cyclotrons for production of medical and industrial isotopes is presented. Compact isochronous cyclotrons which accelerate negative hydrogen ions in the energy range 10 30 MeV have been widely used over the last 25 years for production of medical isotopes and other applications. Different cyclotron models for the energy range 10 12 MeV with moderate beam intensity are used for production of 11C, 13N, 15O, and 18F isotopes widely applied in positron emission tomography. Commercial cyclotrons with high beam intensity are available on the market for production of most medical and industrial isotopes. In this work, the physical and technical parameters of different models are compared. Possibilities of improving performance and increasing intensity of H- beams up to 2 3 mA are discussed.

  2. Multiple Electron Stripping of Heavy Ion Beams

    International Nuclear Information System (INIS)

    Mueller, D.; Grisham, L.; Kaganovich, I.; Watson, R. L.; Horvat, V.; Zaharakis, K. E.; Peng, Y.

    2002-01-01

    One approach being explored as a route to practical fusion energy uses heavy ion beams focused on an indirect drive target. Such beams will lose electrons while passing through background gas in the target chamber, and therefore it is necessary to assess the rate at which the charge state of the incident beam evolves on the way to the target. Accelerators designed primarily for nuclear physics or high energy physics experiments utilize ion sources that generate highly stripped ions in order to achieve high energies economically. As a result, accelerators capable of producing heavy ion beams of 10 to 40 Mev/amu with charge state 1 currently do not exist. Hence, the stripping cross-sections used to model the performance of heavy ion fusion driver beams have, up to now, been based upon theoretical calculations. We have investigated experimentally the stripping of 3.4 Mev/amu Kr 7+ and Xe +11 in N2; 10.2 MeV/amu Ar +6 in He, N2, Ar and Xe; 19 MeV/amu Ar +8 in He, N2, Ar and Xe; 30 MeV He 1 + in He, N2, Ar and Xe; and 38 MeV/amu N +6 in He, N2, Ar and Xe. The results of these measurements are compared with the theoretical calculations to assess their applicability over a wide range of parameters

  3. 32 CFR 724.213 - Attendance of witnesses.

    Science.gov (United States)

    2010-07-01

    ... BOARD Authority/Policy for Departmental Discharge Review § 724.213 Attendance of witnesses. Arrangement for attendance of witnesses testifying in behalf of the applicant at discharge review hearings is the... 32 National Defense 5 2010-07-01 2010-07-01 false Attendance of witnesses. 724.213 Section 724.213...

  4. Experimental assessment of out-of-field dose components in high energy electron beams used in external beam radiotherapy.

    Science.gov (United States)

    Alabdoaburas, Mohamad M; Mege, Jean-Pierre; Chavaudra, Jean; Bezin, Jérémi Vũ; Veres, Atilla; de Vathaire, Florent; Lefkopoulos, Dimitri; Diallo, Ibrahima

    2015-11-08

    The purpose of this work was to experimentally investigate the out-of-field dose in a water phantom, with several high energy electron beams used in external beam radiotherapy (RT). The study was carried out for 6, 9, 12, and 18 MeV electron beams, on three different linear accelerators, each equipped with a specific applicator. Measurements were performed in a water phantom, at different depths, for different applicator sizes, and off-axis distances up to 70 cm from beam central axis (CAX). Thermoluminescent powder dosimeters (TLD-700) were used. For given cases, TLD measurements were compared to EBT3 films and parallel-plane ionization chamber measurements. Also, out-of-field doses at 10 cm depth, with and without applicator, were evaluated. With the Siemens applicators, a peak dose appears at about 12-15 cm out of the field edge, at 1 cm depth, for all field sizes and energies. For the Siemens Primus, with a 10 × 10 cm(²) applicator, this peak reaches 2.3%, 1%, 0.9% and 1.3% of the maximum central axis dose (Dmax) for 6, 9, 12 and 18 MeV electron beams, respectively. For the Siemens Oncor, with a 10 × 10 cm(²) applicator, this peak dose reaches 0.8%, 1%, 1.4%, and 1.6% of Dmax for 6, 9, 12, and 14 MeV, respectively, and these values increase with applicator size. For the Varian 2300C/D, the doses at 12.5 cm out of the field edge are 0.3%, 0.6%, 0.5%, and 1.1% of Dmax for 6, 9, 12, and 18 MeV, respectively, and increase with applicator size. No peak dose is evidenced for the Varian applicator for these energies. In summary, the out-of-field dose from electron beams increases with the beam energy and the applicator size, and decreases with the distance from the beam central axis and the depth in water. It also considerably depends on the applicator types. Our results can be of interest for the dose estimations delivered in healthy tissues outside the treatment field for the RT patient, as well as in studies exploring RT long-term effects.

  5. Micro-patterns fabrication using focused proton beam lithography

    Energy Technology Data Exchange (ETDEWEB)

    Cutroneo, M., E-mail: cutroneo@ujf.cas.cz [Nuclear Physics Institute, AS CR, 25068 Rez (Czech Republic); Havranek, V. [Nuclear Physics Institute, AS CR, 25068 Rez (Czech Republic); Mackova, A. [Nuclear Physics Institute, AS CR, 25068 Rez (Czech Republic); Department of Physics, Faculty of Science, J.E. Purkinje University, Ceske mladeze 8, 400 96 Usti nad Labem (Czech Republic); Semian, V. [Nuclear Physics Institute, AS CR, 25068 Rez (Czech Republic); Torrisi, L. [Department of Physics and Earth Sciences, Messina University, V.le F.S. d’Alcontres 31, 98166 S. Agata, Messina (Italy); Calcagno, L. [Department of Physics, Catania University, V. S. Sofia 64, 95123 Catania (Italy)

    2016-03-15

    Proton beam writing technique was recently introduced at 3MV Tandetron accelerator at Nuclear Physics Institute in Rez (Czech Republic). It has been used, to produce three-dimensional (3D) micro-structures in poly(methylmethacrylate) by 2.0 MeV and 2.6 MeV protons micro-beam. Micro-channels (52 μm × 52 μm) have been realized. After chemical etching, the quality of the bottom and side walls of the produced structures in PMMA were analyzed using Scanning Transmission Ion Microscopy (STIM).

  6. Comparison of experimental and Monte-Carlo simulation of MeV particle transport through tapered/straight glass capillaries and circular collimators

    Energy Technology Data Exchange (ETDEWEB)

    Hespeels, F., E-mail: felicien.hespeels@unamur.be [University of Namur, PMR, 61 rue de Bruxelles, 5000 Namur (Belgium); Tonneau, R. [University of Namur, PMR, 61 rue de Bruxelles, 5000 Namur (Belgium); Ikeda, T. [RIKEN Nishina Center, 2-1 Hirosawa, Wako, Saitama 351-0198 (Japan); Lucas, S. [University of Namur, PMR, 61 rue de Bruxelles, 5000 Namur (Belgium)

    2015-11-01

    Highlights: • Monte-Carlo simulation for beam transportation through collimations devices. • We confirm the focusing effect of tapered glass capillary. • We confirm the feasibility of using passive collimation devices for ion beam analysis application. - Abstract: This study compares the capabilities of three different passive collimation devices to produce micrometer-sized beams for proton and alpha particle beams (1.7 MeV and 5.3 MeV respectively): classical platinum TEM-like collimators, straight glass capillaries and tapered glass capillaries. In addition, we developed a Monte-Carlo code, based on the Rutherford scattering theory, which simulates particle transportation through collimating devices. The simulation results match the experimental observations of beam transportation through collimators both in air and vacuum. This research shows the focusing effects of tapered capillaries which clearly enable higher transmission flux. Nevertheless, the capillaries alignment with an incident beam is a prerequisite but is tedious, which makes the TEM collimator the easiest way to produce a 50 μm microbeam.

  7. 32 CFR 516.54 - Witnesses for the United States.

    Science.gov (United States)

    2010-07-01

    ... 32 National Defense 3 2010-07-01 2010-07-01 true Witnesses for the United States. 516.54 Section..., Travel, and Expenses of Witnesses § 516.54 Witnesses for the United States. (a) Status of witness. A military member authorized to appear as a witness for the United States, including those authorized to...

  8. Free electron laser facilities employing a 150-MeV linac injector for Saga synchrotron light source

    International Nuclear Information System (INIS)

    Tomimasu, T.; Yasumoto, M.; Ochiai, Y.; Ishibashi, M.; Murayama, T.

    1999-01-01

    Free electron laser (FEL) facilities as the FELI FEL Facility are proposed, for which a 150-MeV linac type injector for a Saga synchrotron light source (SLS) is employed in FEL mode. The linac has two operating modes; short macropulse mode a 1 μs at 150 MeV for injection to a 1 - 1.3-GeV third generation type storage ring and long macropulse mode of 12 μs at 100 MeV for four FEL Facilities. The macropulse beam consists of a train of several ps, 0.6 nC microbunches (peak current 100 A) repeating at 89.25 MHz. We are aiming to supply high power level photon beams covering an attractive wavelength range from 0.05 nm (25 keV) to 200 μm (0.006 eV) for scientific researches, bio-medical and industrial applications, using the Saga third generation type SLS with a superconducting wiggler and the proposed four FEL Facilities. (author)

  9. Effects of sawtooth crashes on beam ions and fusion product tritons in JET

    Energy Technology Data Exchange (ETDEWEB)

    Marcus, F.B.; Hone, M.A.; Jarvis, O.N.; Loughlin, M.J.; Sadler, G. [Commission of the European Communities, Abingdon (United Kingdom). JET Joint Undertaking; Adams, J.M.; Bond, D.S.; Watkins, N. [AEA Technology, Harwell (United Kingdom); Howarth, P.J.A. [Birmingham Univ. (United Kingdom)

    1994-12-31

    The objective of this study is to examine the effect of a sawtooth crash on the radial distribution of the slowing down fusion product tritons and on beam ions. The JET neutron emission profile monitor was used to measure the 2.5 MeV and 14 MeV neutron emission line-integrals before and after sawtooth crashes in the Joint European Torus (JET). In deuterium discharges, the 14 MeV neutron production was wholly attributable to burnup of the 1 MeV fusion product tritons from d-d fusion. It has been known for many years that the global emission of 14 MeV neutrons is not affected by sawtooth crashes. Examination of the data obtained with the profile monitor shows that the local emissivity of 14 MeV neutrons, and hence of the profile of thermalizing tritons, is only weakly affected by crashes in the discharges studied. This is in contradiction with the apparent behaviour of injected beam ions as deduced from a study of the considerable changes in local emissivity of the 2.5 MeV neutrons. Nevertheless, the behaviour of the fusion product tritons is consistent with the scaling of the beam injected deuterium. (author) 1 ref., 6 figs.

  10. Beam tests on a proton linac booster for hadron therapy

    CERN Document Server

    De Martinis, C; Berra, P; Birattari, C; Calabretta, L; Crandall, K; Giove, D; Masullo, M R; Mauri, M; Rosso, E; Rovelli, A; Serafini, L; Szeless, Balázs; Toet, D Z; Vaccaro, Vittorio G; Weiss, M; Zennaro, R

    2002-01-01

    LIBO is a 3 GHz modular side-coupled proton linac booster designed to deliver beam energies up to 200 MeV, as required for the therapy of deep seated tumours. The injected beam of 50 to 70 MeV is produced by a cyclotron like those in several hospitals and research institutes. A full-scale prototype of the first module with an input/output energy of 62/74 MeV, respectively, was designed and built in 1999 and 2000. Full power RF tests were carried out successfully at CERN using a test facility at LIL at the end of the year 2000. In order to prove the feasibility of the acceleration process, an experimental setup with this module was installed at the INFN Laboratorio Nazionale del Sud (LNS) in Catania during 2001. The superconducting cyclotron provided the 62 MeV test beam. A compact solid-state RF modulator with a 4 MW klystron, made available by IBA-Scanditronix, was put into operation to power the linac. In this paper the main features of the accelerator are reviewed and the experimental results obtained duri...

  11. High resolution line for secondary radioactive beams at the U400M cyclotron

    International Nuclear Information System (INIS)

    Rodin, A.M.; Sidorchuk, S.I.; Stepantsov, S.V.

    1996-01-01

    For implementation of an experimental program for studying nuclear reactions with radioactive ion beams in the energy domain of 20 through 80 MeV · A the high resolution beam line ACCULINNA was put into commissioning on a primary beam line of the JINR U-400M cyclotron. By means of nuclear fragmentation of the 14 N beam with the energy of 51 MeV · A on the 170 mg/cm 2 carbon target radioactive beams of 6 He, 8 He and 8 B were obtained. Possibilities of further development of the set-up are discussed. 6 refs., 7 figs., 2 tabs

  12. External proton and Li beams; Haces externos de protones y litios

    Energy Technology Data Exchange (ETDEWEB)

    Schuff, Juan A; Burlon, Alejandro A; Debray, Mario E; Kesque, Jose M; Kreiner, Andres J; Stoliar, Pablo A; Naab, Fabian; Ozafran, Mabel J; Vazquez, Monica E [Comision Nacional de Energia Atomica, General San Martin (Argentina). Dept. de Fisica; Policastro, Lucia L; Duran, Hebe; Molinari, Beatriz L; O' Connor, Silvia E; Saint-Martin, Maria L.G.; Palmieri, Monica; Bernaola, Omar A; Opezzo, Oscar J [Comision Nacional de Energia Atomica, General San Martin (Argentina). Dept. de Radiobiologia; Mazal, A; Favaudon, F; Henry, Y [Institut Curie, 75 - Paris (France); Perez de la Hoz, A.; Somacal, Hector; Valda, Alejandro; Canevas, S; Ruffolo, M; Tasat, D R [Universidad Nacional de General San Martin, Villa Ballester (Argentina). Escuela de Ciencia y Tecnologia; Davidson, Miguel; Davidson, Jorge [Buenos Aires Univ. (Argentina). Dept. de Fisica; Delacroix, S; Nauraye, C; Brune, E; Gautier, C; Habrand, J L [Centre de Protontherapie, 91 - Orsay (France); Muhlmann, M C [Consejo Nacional de Investigaciones Cientificas y Tecnicas (CONICET), Buenos Aires (Argentina)

    2000-07-01

    In the frame of a feasibility study to introduce proton therapy in Argentina in a collaborative agreement between the Physics and Radiobiology Departments of the National Atomic Energy Commission or Argentina and the Centre de Protontherapie de Orsay, France, external proton and Li beams were produced at the TANDAR accelerator in Buenos Aires. The specific aim of this work was to start radiobiology studies on cell cultures and small laboratory animals. In particular we seek to determine here the relative biological effectiveness, RBE, for proton and Li beams as a function of energy for different tumor and normal cell lines. The 24 MeV proton beam was diffused using a 25 {mu}m gold foil and extracted through a Kapton window to obtain a homogeneous field (constant to 95%) of about 7 cm in diameter. Measurements were carried out with quasi-monoenergetic beams (of 20.2 {+-} 0.07 MeV, 2.9 {+-} 0.10 MeV y 1.5 {+-} 0.1 MeV for protons and 21.4 {+-} 0.4 MeV for Lithium). Proton fluence and Bragg peaks were measured. The dose delivered in each case was monitored on-line with a calibrated transmission ionization chamber. Three cell lines PDV, PDVC 57 and V 79 (as a reference) were irradiated with {gamma}-rays, proton and lithium beams with linear energy transfer (LET) from 2 to 100 keV/{mu}m. RBE values in the range of 1.2-5.9 were obtained. In addition preliminary studies on chromosomal aberrations and viability of alveolar macrophages were carried out. (author)

  13. Expert Witness

    African Journals Online (AJOL)

    Adele

    formal rules of evidence apply) to help it understand the issues of a case and ... statements on medical expert witness by professional representative bodies in .... determining the size of the financial settlement that may have to be made to the.

  14. Calculation of nucleon production cross sections for 200 MeV deuterons

    International Nuclear Information System (INIS)

    Ridikas, D.; Mittig, W.

    1997-01-01

    The differential neutron and proton production cross sections have been investigated for 200 MeV incident deuterons on thin and thick 9 Be, 56 Fe and 238 U targets using the LAHET code system. The examples of the deuteron beam on different target materials are analysed to determine the differences of converting the energy of the beam into the nucleons produced. Both double differential, energy and angle integrated nuclear production cross sections are presented together with the average nucleon multiplicities per incident deuteron. (K.A.)

  15. Beam-energy and laser beam-profile monitor at the BNL LINAC

    Energy Technology Data Exchange (ETDEWEB)

    Connolly, R.; Briscoe, B.; Degen, C.; DeSanto, L.; Meng, W.; Minty, M.; Nayak, S.; Raparia, D.; Russo, T.

    2010-05-02

    We are developing a non-interceptive beam profile and energy monitor for H{sup -} beams in the high energy beam transport (HEBT) line at the Brookhaven National Lab linac. Electrons that are removed from the beam ions either by laser photodetachment or stripping by background gas are deflected into a Faraday cup. The beam profile is measured by stepping a narrow laser beam across the ion beam and measuring the electron charge vs. transverse laser position. There is a grid in front of the collector that can be biased up to 125kV. The beam energy spectrum is determined by measuring the electron charge vs. grid voltage. Beam electrons have the same velocity as the beam and so have an energy of 1/1836 of the beam protons. A 200MeV H{sup -} beam yields 109keV electrons. Energy measurements can be made with either laser-stripped or gas-stripped electrons.

  16. 12 CFR 512.5 - Rights of witnesses.

    Science.gov (United States)

    2010-01-01

    ... has given. During the taking of the testimony of a witness, such attorney may make summary notes... before, during, and after the taking of his testimony and may briefly question the witness, on the record... permitted to be present during the taking of testimony of any other witness called in such proceeding...

  17. High flux, beamed neutron sources employing deuteron-rich ion beams from D2O-ice layered targets

    Science.gov (United States)

    Alejo, A.; Krygier, A. G.; Ahmed, H.; Morrison, J. T.; Clarke, R. J.; Fuchs, J.; Green, A.; Green, J. S.; Jung, D.; Kleinschmidt, A.; Najmudin, Z.; Nakamura, H.; Norreys, P.; Notley, M.; Oliver, M.; Roth, M.; Vassura, L.; Zepf, M.; Borghesi, M.; Freeman, R. R.; Kar, S.

    2017-06-01

    A forwardly-peaked bright neutron source was produced using a laser-driven, deuteron-rich ion beam in a pitcher-catcher scenario. A proton-free ion source was produced via target normal sheath acceleration from Au foils having a thin layer of D2O ice at the rear side, irradiated by sub-petawatt laser pulses (˜200 J, ˜750 fs) at peak intensity ˜ 2× {10}20 {{W}} {{cm}}-2. The neutrons were preferentially produced in a beam of ˜70° FWHM cone along the ion beam forward direction, with maximum energy up to ˜40 MeV and a peak flux along the axis ˜ 2× {10}9 {{n}} {{sr}}-1 for neutron energy above 2.5 MeV. The experimental data is in good agreement with the simulations carried out for the d(d,n)3He reaction using the deuteron beam produced by the ice-layered target.

  18. Measurement of (n,Xn) reaction cross sections at 96 MeV; Measure des sections efficaces (n,Xn) a 96 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Sagrado Garcia, Melle Inmaculada C. [Ecole Doctorale: SINEM, U.F.R. de Sciences, Universite de Caen/Basse-Normandie, Esplanade Paix14000 Caen (France)

    2006-10-15

    Nucleon induced reactions in the 20-200 MeV energy range are intensively studied since a long time. The evaporation and the pre-equilibrium processes correspond to an important contribution of the production cross section in these reactions. Several theoretical approaches have been proposed and their predictions must be tested. The experimental results shown in this work are the only complete set of data for the (n,Xn) reactions in this energy range. Neutron double differential cross section measurements using lead and iron targets for an incident neutron beam at 96 MeV were carried out at TSL Laboratory in Uppsala, Sweden. The measurements have been performed for the first time with an energy threshold of 2 MeV and for a wide angular range (15 angle - 98 angle). Neutrons have been detected using two independent setups, DECOI and DEMON and CLODIA and SCANDAL, in order to cover the whole energy range (2-100) MeV. The angular distributions, the differential cross sections and the total inelastic production cross sections have been calculated using the double differential cross sections. The comparison between the experimental data and the predictions given by two of the most popular simulation codes, GEANT3 and MCNPX, have been performed, as well as the comparison with the predictions of the microscopic simulation model DYWAN, selected for its treatment of nucleon-nucleon reactions. (author)

  19. High intensity beam profile monitors for the LAMPF primary beam lines

    International Nuclear Information System (INIS)

    Hoffman, E.W.; Macek, R.J.; van Dyck, O.; Lee, D.; Harvey, A.; Bridge, J.; Cainet, J.

    1979-01-01

    Two types of beam profile monitors are in use at LAMPF to measure the properties of the 800 MeV, 500 μA proton beam external to the linac. Both types use secondary electron emission from a wire to produce a current signal proportional to the amount of proton beam that intercepts the wire. The wire scanner system uses a pair of orthogonal wires which are passed through the beam and the harp system uses two fixed planes of parallel wires. Most of the harps are not retractable and are exposed continuously to the primary beam. The high beam intensities available lead to a number of technical problems for instruments that intercept the beam or are close to primary beam targets. The thermal, electrical, radiation-damage, and material selection problems encountered, and some solutions which have been implemented are discussed

  20. Nuclear photon science with inverse compton photon beam

    International Nuclear Information System (INIS)

    Fujiwara, Mamoru

    2007-01-01

    Recent developments of the synchrotron radiation facilities and intense lasers are now guiding us to a new research frontier with probes of a high energy GeV photon beam and an intense and short pulse MeV γ-ray beam. New directions of the science developments with photo-nuclear reactions are discussed. The inverse Compton γ-ray has two good advantages for searching for a microscopic quantum world; they are 1) good emittance and 2) high linear and circular polarizations. With these advantages, photon beams in the energy range from MeV to GeV are used for studying hadron structure, nuclear structure, astrophysics, materials science, as well as for applying medical science. (author)

  1. Effect Of The LEBT Solenoid Magnetic Field On The Beam Generation For Particle Tracking

    CERN Document Server

    Yarmohammadi Satri, M; CERN. Geneva. ATS Department

    2013-01-01

    Linac4 is a 160 MeV H- linear accelerator which will replace the 50 MeV proton Linac2 for upgrade of the LHC injectors with higher intensity and eventually an increase of the LHC luminosity. Linac4 structure is a source, a 45 keV low energy beam transport line (LEBT) with two solenoids, a 3 MeV Radiofrequency Quadrupole (RFQ), a Medium Energy Beam Transport line (MEBT), a 50 Mev DTL, a 100 Mev CCDTL and PIMS up to 160 Mev. We use Travel v4.07 and PathManager code for simulation. Firstly, we need to a file as a source and defining the beginning point (last point in tracking back) of simulation. We recognise the starting point base on the solenoid magnetic property of LEBT.

  2. 6 CFR 13.33 - Witnesses.

    Science.gov (United States)

    2010-01-01

    ... 6 Domestic Security 1 2010-01-01 2010-01-01 false Witnesses. 13.33 Section 13.33 Domestic Security DEPARTMENT OF HOMELAND SECURITY, OFFICE OF THE SECRETARY PROGRAM FRAUD CIVIL REMEDIES § 13.33 Witnesses. (a) Except as provided in paragraph (b) of this section, testimony at the hearing will be given orally by...

  3. Bearing witness: an existential position in caring.

    Science.gov (United States)

    Arman, Maria

    2007-12-01

    A basic assumption for the study is that perceiving a person's deepest needs and desires to be on hand for another person, and their attempt to do so, have, in an ontological sense, the power to bear witness of goodness and eternity. The study was based on a theoretical basis of a caring science view of suffering, as well as the ethics of the philosopher Lévinas. The aim was to explore and clinically validate nuances of witnessing as a caring act.A Socratic dialogue was performed and an interpretive (hermeneutic) method was employed in this study. The Socratic dialogue with four nurses in palliative care focused on and analysed one clinical example of witnessing in palliative care. As basis for the findings are the participating nurses jointly formulated assumptions on the subject: To be a witness you have to be with the patient and refer back to him or her what you have seen; but also to act in accordance with what you have perceived. In the moment you witness, a window is opened onto the unknown; you become vulnerable as a caregiver and require courage. Being a witness encompasses existential and spiritual aspects; being a fellow human being, having a heart to heart relationship is a wilful act on the part of the nurse. Our theoretical discussion focuses on the language of the body, courage as a bridge to an existential encounter and the alleviation of patients' suffering through caregivers' witnessing. A conclusive aspect is that being a witness may bring a new understanding of life in the face of death and suffering. The existential position of being a witness requires the caregiver to be courageous because of its transformative prospect, but may utterly enrich both parties' inner life of shared meaning.

  4. Measurement of the analysing power of elastic proton-proton scattering at 582 MeV

    International Nuclear Information System (INIS)

    Berdoz, A.; Favier, B.; Foroughi, F.; Weddigen, C.

    1984-01-01

    The authors have measured the analysing power of elastic proton-proton scattering at 582 MeV for 14 angles from 20 to 80 0 CM. The angular range was limited to >20 0 by the energy loss of the recoil protons. The experiment was performed at the PM1 beam line at SIN. A beam intensity of about 10 8 particles s -1 was used. (Auth.)

  5. Stripping Foil Issues for H- Injection into the CERN PSB at 160 MeV

    CERN Document Server

    Goddard, B; Bracco, C; Carli, C; Meddahi, M; Weterings, W J M

    2010-01-01

    Beam physics considerations for the stripping foil of the 160 MeV PSB H- injection systems are described, including the arguments for the foil type, thickness, geometry and positioning. The foil performance considerations are described, including expected stripping efficiency, emittance growth, energy straggling, temperature and lifetime. The different beam loss mechanisms are quantified in the context of the aperture limits, operational considerations and collimation requirements.

  6. Betatrons with kiloampere beams

    International Nuclear Information System (INIS)

    Peterson, J.M.

    1982-11-01

    Although the magnetic-induction method of acceleration used in the betatron is inherently capable of accelerating intense particle beams to high energy, many beam-instability questions arise when beams in the kilo-ampere range are considered. The intense electromagnetic fields produced by the beam, and by the image currents and charges induced in the surrounding walls, can produce very disruptive effects. Several unstable modes of collective oscillation are possible; the suppression of any one of them usually involves energy spread for Landau damping and careful design of the electrical character of the vacuum chamber. The various design criteria are often mutually incompatible. Space-charge detuning can be severe unless large beam apertures and high-energy injection are used. In order to have an acceptably low degree of space-charge detuning in the acceleration of a 10-kilo-ampere electron beam, for example, an injection energy on the order of 50 MeV seems necessary, in which case the forces due to nearby wall images can have a larger effect than the internal forces of the beam. A method of image compensation was invented for reducing the net image forces; it serves also to decrease the longitudinal beam impedance and thus helps alleviate the longitudinal instability as well. In order to avoid the ion-electron collective instability a vacuum in the range of 10 - 8 torr is required for an acceleration time of 1 millisecond. A multi-ring betatron system using the 50-MeV Advanced Test Accelerator at LLNL as an injector was conceptually designed

  7. Study of the reaction 22Ne(131 MeV) + 208Pb with a PIAVE-ALPI test beam and the PRISMA-CLARA set-up

    International Nuclear Information System (INIS)

    Mason, P.; Marginean, N.; Stefanini, A.M.

    2005-01-01

    An opportunity to study the system 22 Ne+ 208 Pb in the proximity of the Coulomb barrier with the PRISMACLARA apparatus was given by a test of the PIAVE-ALPI accelerator in mid-December 2005. The 22 Ne projectiles, having the kinetic energy of 131 MeV, collided with a 208 Pb target 300 μg/cm 2 thick. (The beam was run for ∼20 hours with a current of ∼6 particle-nA). The reaction products, mainly originated by scattering or transfer processes, were detected by the PRISMA spectrometer (positioned in the proximity of the grazing angle, ∼70 degrees), coupled to the CLARA array of germanium detectors

  8. An integral test of FLUKA nuclear models with 160 MeV proton beams in multi-layer Faraday cups

    CERN Document Server

    Rinaldi, I; Parodi, K; Ferrari, A; Sala, P; Mairani, A

    2011-01-01

    Monte Carlo (MC) codes are useful tools to simulate the complex processes of proton beam interactions with matter. In proton therapy, nuclear reactions influence the dose distribution. Therefore, the validation of nuclear models adopted in MC codes is a critical requisite for their use in this field. A simple integral test can be performed using a multi-layer Faraday cup (MLFC). This method allows separation of the nuclear and atomic interaction processes, which are responsible for secondary particle emission and the finite primary proton range, respectively. In this work, the propagation of 160 MeV protons stopping in two MLFCs made of polyethylene and copper has been simulated by the FLUKA MC code. The calculations have been performed with and without secondary electron emission and transport, as well as charge sharing in the dielectric layers. Previous results with other codes neglected those two effects. The impact of this approximation has been investigated and found to be relevant only in the proximity ...

  9. Decontamination of drug vegetative raw material by relativistic electron beam

    International Nuclear Information System (INIS)

    Gorbanyuk, A.G.; Dikiy, I.L.; Yegorov, A.M.; Linnik, A.F.; Uskov, V.V.

    2004-01-01

    The new technology of decontamination of drug vegetative raw material and medical products is proposed. Advantages of use of relativistic beams in a range of electron energies from 0.5 MeV to 5 MeV for these purposes are shown in comparison with X-radiation of energy from 80 keV to 1 MeV

  10. Study on dynamics of beams of high luminosity in electron linacs

    International Nuclear Information System (INIS)

    Polyakov, V.A.; Shchedrin, I.S.

    1981-01-01

    To increase the electron beam luminosity in electron linacs (ELA), designed for electron microscopy, a numerical analysis of the electron dynamics in the ELA is carried out. Insufficiency of the available data on longitudinal beam motion in the 10 -4 -10 -5 relative energy spread on radial motion, as well as inadequacy of the data on aberrations of the second order introduced by the accelerating structure are shown. The necessary accountancy of the longitudinal Coulomb field is also shown. For the 1-10 MeV electron energies, 10 9 and 5x10 9 cm -3 bunch density, 5 deg-0.5 deg phase extension the beam current varies within the 0.2-10 mA. The bunch moves in the drift space of the 2.5 m length. The energy spread is 8x10 -8 (1 MeV) to 10 -4 (10 MeV) at the 2 mA beam current [ru

  11. Energy dependence of EBT-1 radiochromic film response for photon (10 kvp-15 MVp) and electron beams (6-18 MeV) readout by a flatbed scanner.

    Science.gov (United States)

    Richter, Christian; Pawelke, Jörg; Karsch, Leonhard; Woithe, Julia

    2009-12-01

    The aim of this article is to investigate the energy dependence of the radiochromic film type, Gafchromic EBT-1, when scanned with a flatbed scanner for film readout. Dose response curves were determined for 12 different beam qualities ranging from a 10 kVp x-ray beam to a 15 MVp x-ray beam and include also two high energy electron beam qualities (6 and 18 MeV). The dose responses measured as net optical density (netOD) for the different beam qualities were normalized to the response of a reference beam quality (6 MVp). A strong systematic energy dependence of the film response was found. The lower the effective beam energy, the less sensitive the EBT-1 films get. The maximum decrease in dose for the same film response between the 25 kVp and 6 MVp beam qualities was 44%. Additionally, a difference in energy dependence for different doses was discovered, meaning that higher doses show a smaller dependency on energy than lower doses. The maximum decrease in the normalized netOD was found to be 25% for a dose of 0.5 Gy relative to the normalized netOD for 10 Gy. Moreover, a scaling procedure is introduced, allowing the correction of the energy dependence for the investigated beam qualities and also for comparable x-ray beam qualities within the energy range studied. A strong energy dependence for EBT-1 radiochromic films was found. The films were readout with a flatbed scanner. If the effective beam energy is known, the energy dependence can be corrected with the introduced scaling procedure. Further investigation of the influence of the spectral band of the readout device on energy dependence is needed to understand the reason for the different energy dependences found in this and previous works.

  12. Development and application of a water calorimeter for the absolute dosimetry of short-range particle beams

    Science.gov (United States)

    Renaud, J.; Rossomme, S.; Sarfehnia, A.; Vynckier, S.; Palmans, H.; Kacperek, A.; Seuntjens, J.

    2016-09-01

    In this work, we describe a new design of water calorimeter built to measure absorbed dose in non-standard radiation fields with reference depths in the range of 6-20 mm, and its initial testing in clinical electron and proton beams. A functioning calorimeter prototype with a total water equivalent thickness of less than 30 mm was constructed in-house and used to obtain measurements in clinical accelerator-based 6 MeV and 8 MeV electron beams and cyclotron-based 60 MeV monoenergetic and modulated proton beams. Corrections for the conductive heat transfer due to dose gradients and non-water materials was also accounted for using a commercial finite element method software package. Absorbed dose to water was measured with an associated type A standard uncertainty of approximately 0.4% and 0.2% for the electron and proton beam experiments, respectively. In terms of thermal stability, drifts were on the order of a couple of hundred µK min-1, with a short-term variation of 5-10 µK. Heat transfer correction factors ranged between 1.021 and 1.049. The overall combined standard uncertainty on the absorbed dose to water was estimated to be 0.6% for the 6 MeV and 8 MeV electron beams, as well as for the 60 MeV monoenergetic protons, and 0.7% for the modulated 60 MeV proton beam. This study establishes the feasibility of developing an absorbed dose transfer standard for short-range clinical electrons and protons and forms the basis for a transportable dose standard for direct calibration of ionization chambers in the user’s beam. The largest contributions to the combined standard uncertainty were the positioning (⩽0.5%) and the correction due to conductive heat transfer (⩽0.4%). This is the first time that water calorimetry has been used in such a low energy proton beam.

  13. Polypropylene compositional evolution under 3.5 MeV He+ ion irradiation

    Science.gov (United States)

    Abdesselam, M.; Muller, D.; Djebara, M.; Chami, A. C.; Montgomery, P.

    2012-05-01

    A helium beam at 3.5 MeV was used to induce damage in thin polypropylene film of 5.1 μm in thickness. The fluence ranges from 2 × 1012 to 3.5 × 1015 cm-2. The evolution of the atomic composition (C and H) as a function of the fluence was investigated in situ by forward elastic scattering (C(α, α)C) and hydrogen elastic recoil detection (H(α, H)α), respectively. The helium beam was used at the same time for irradiation and analysis. In respect to the high sensitivity of the polypropylene to radiation damage, the beam current was kept at very low intensity of 0.5 nA. The mass loss becomes significant above a fluence of ˜5 × 1013 He+ cm-2. The carbon depletion levels off at a fluence of ˜5 × 1014 He+ cm-2 approximately while hydrogen loss continues to be present along the whole of the studied fluence range. The final carbon and hydrogen losses, at the highest fluence, are around 17% and 48% of their initial contents, respectively. Satisfactory fits to the release curves have been obtained in the framework of the bulk molecular recombination model (BMR). The deduced hydrogen and carbon release cross sections are 7.8 and 65.2 × 10-16 cm2, respectively. A comparison with our previous measurements of polyethylene terephthalate (PET) film irradiated with 3.7 MeV He+ beam is made.

  14. The SCANDAL facility - How to measure elastic neutron scattering in the 50-130 MeV range

    International Nuclear Information System (INIS)

    Klug, Joakim

    2001-01-01

    The interest in neutrons of energies above 20 MeV is growing rapidly, since new applications are being developed or have been identified. Transmutation of nuclear waste and cancer therapy with neutron beams are two research fields that would benefit from new neutron scattering data at these energies. A facility for detection of scattered neutrons in the energy interval 50-130 MeV, SCANDAL (SCAttered Nucleon Detection AssembLy), has been developed and installed at the neutron beam facility of the The Svedberg Laboratory in Uppsala. It can be used to study the (n,n), (n,p) and (n,d) reactions. This thesis describes the layout of the setup, the experimental procedure, and data analysis principles. The performance of the spectrometer is illustrated with measurements of the (n,p) and (n,n) reactions on 1 H and 12 C. In addition, the neutron beam facility is described in some detail

  15. Kinetic energy spectrum and polarization of neutrons from the reaction 12C(p,n)X at 590 MeV

    International Nuclear Information System (INIS)

    Arnold, J.

    1998-01-01

    The kinetic energy spectrum and the polarization of the PSI neutron beam produced in the reaction 12 C(p,n)X at 0 with 590 MeV polarized protons were investigated. A strong energy dependence of the neutron beam polarization is observed which was not expected at the time the neutron beam was built. (orig.)

  16. The 16 MeV - microtron at the Institute for Physics and Technology of Radiation Devices and its application

    International Nuclear Information System (INIS)

    Catana, D.; Panaitescu, I.; Axinescu, S.; Minea, R.

    1992-01-01

    The 17-orbit microtron at the Institute for Physics and Technology of Radiation Devices, Bucharest is described. The energy of electrons is 11 MeV in the first accelerating mode and 16 MeV in the second accelerating mode with a pulse beam power of about 400 Kw and a duty ratio of 10 -3 . (Author)

  17. New developments of 11C post-accelerated beams for hadron therapy and imaging

    Science.gov (United States)

    Augusto, R. S.; Mendonca, T. M.; Wenander, F.; Penescu, L.; Orecchia, R.; Parodi, K.; Ferrari, A.; Stora, T.

    2016-06-01

    Hadron therapy was first proposed in 1946 and is by now widespread throughout the world, as witnessed with the design and construction of the CNAO, HIT, PROSCAN and MedAustron treatment centres, among others. The clinical interest in hadron therapy lies in the fact that it delivers precision treatment of tumours, exploiting the characteristic shape (the Bragg peak) of the energy deposition in the tissues for charged hadrons. In particular, carbon ion therapy is found to be biologically more effective, with respect to protons, on certain types of tumours. Following an approach tested at NIRS in Japan [1], carbon ion therapy treatments based on 12C could be combined or fully replaced with 11C PET radioactive ions post-accelerated to the same energy. This approach allows providing a beam for treatment and, at the same time, to collect information on the 3D distributions of the implanted ions by PET imaging. The production of 11C ion beams can be performed using two methods. A first one is based on the production using compact PET cyclotrons with 10-20 MeV protons via 14N(p,α)11C reactions following an approach developed at the Lawrence Berkeley National Laboratory [2]. A second route exploits spallation reactions 19F(p,X)11C and 23Na(p,X)11C on a molten fluoride salt target using the ISOL (isotope separation on-line) technique [3]. This approach can be seriously envisaged at CERN-ISOLDE following recent progresses made on 11C+ production [4] and proven post-acceleration of pure 10C3/6+ beams in the REX-ISOLDE linac [5]. Part of the required components is operational in radioactive ion beam facilities or commercial medical PET cyclotrons. The driver could be a 70 MeV, 1.2 mA proton commercial cyclotron, which would lead to 8.1 × 10711C6+ per spill. This intensity is appropriate using 11C ions alone for both imaging and treatment. Here we report on the ongoing feasibility studies of such approach, using the Monte Carlo particle transport code FLUKA [6,7] to simulate

  18. Design of the proposed 250 MeV superconducting cyclotron magnet for proton therapy

    International Nuclear Information System (INIS)

    Dey, M.K.; Ahmed, M.; Murali, S.; Duttagupta, A.; Chaudhuri, J.; Mallik, C.; Bhandari, R.K.

    2006-01-01

    Here we describe the design calculations for the superconducting magnet of a 250 MeV proton cyclotron to be used for therapeutic purpose. Hard-edge approximation method has been adopted for finding the poletip geometry to meet the basic focusing requirements of the beam. Then the uniform-magnetization method has been applied to calculate the 3D magnetic field distribution due to saturated iron poletips, to verify the beam dynamical issues. (author)

  19. A Complete Reporting of MCNP6 Validation Results for Electron Energy Deposition in Single-Layer Extended Media for Source Energies <= 1-MeV

    Energy Technology Data Exchange (ETDEWEB)

    Dixon, David A. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Hughes, Henry Grady [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-05-04

    In this paper, we expand on previous validation work by Dixon and Hughes. That is, we present a more complete suite of validation results with respect to to the well-known Lockwood energy deposition experiment. Lockwood et al. measured energy deposition in materials including beryllium, carbon, aluminum, iron, copper, molybdenum, tantalum, and uranium, for both single- and multi-layer 1-D geometries. Source configurations included mono-energetic, mono-directional electron beams with energies of 0.05-MeV, 0.1-MeV, 0.3- MeV, 0.5-MeV, and 1-MeV, in both normal and off-normal angles of incidence. These experiments are particularly valuable for validating electron transport codes, because they are closely represented by simulating pencil beams incident on 1-D semi-infinite slabs with and without material interfaces. Herein, we include total energy deposition and energy deposition profiles for the single-layer experiments reported by Lockwood et al. (a more complete multi-layer validation will follow in another report).

  20. Scattering of 14.2 MeV polarized neutrons from 12C

    International Nuclear Information System (INIS)

    Casparis, R.; Leemann, B.Th.; Preiswerk, M.; Rudin, H.; Wagner, R.; Zupranski, P.

    1976-01-01

    Polarized 14.2 MeV neutrons with a polarization of approximately 50% were produced in the 3 H(d(pol),n(pol)) 4 He reaction using vector polarized deuterons from an 'atomic beam' source of polarized ions. The angular distributions of the analyzing power in the elastic and inelastic (Q = -4.43 MeV) scattering of neutrons from carbon have been measured at ten angles in the range from 22 0 to 152 0 c.m. A time-of-flight technique was used to separate elastically and inelastically scattered neutrons. The results have been compared with theoretical calculations obtained with the DWBA and the coupled channels method. (Auth.)

  1. Calculation of nucleon production cross sections for 200 MeV deuterons

    Energy Technology Data Exchange (ETDEWEB)

    Ridikas, D.; Mittig, W.

    1997-12-31

    The differential neutron and proton production cross sections have been investigated for 200 MeV incident deuterons on thin and thick {sup 9}Be, {sup 56}Fe and {sup 238}U targets using the LAHET code system. The examples of the deuteron beam on different target materials are analysed to determine the differences of converting the energy of the beam into the nucleons produced. Both double differential, energy and angle integrated nuclear production cross sections are presented together with the average nucleon multiplicities per incident deuteron. (K.A.). 31 refs.

  2. Calibration of a large multi-element neutron counter in the energy range 85-430 MeV

    CERN Document Server

    Strong, J A; Esterling, R J; Garvey, J; Green, M G; Harnew, N; Jane, M R; Jobes, M; Mawson, J; McMahon, T; Robertson, A W; Thomas, D H

    1978-01-01

    Describes the calibration of a large 60 element neutron counter with a threshold of 2.7 MeV equivalent electron energy. The performance of the counter has been measured in the neutron kinetic energy range 8.5-430 MeV using a neutron beam at the CERN Synchrocyclotron. The results obtained for the efficiency as a function of energy are in reasonable agreement with a Monte Carlo calculation. (7 refs).

  3. Application of the Ethanol-Chlorobenzene Dosimeter to Electron Beam Dosimetry: Pulsed 10 MeV Electrons

    Energy Technology Data Exchange (ETDEWEB)

    Dvornik, I.; Razem, D.; Baric, M. [Institute ' ' Ruder Boskovic' ' , Zagreb, Yugoslavia (Croatia)

    1969-12-15

    With gamma irradiation, the ethanol-chlorobenzene chemical dosimetric systems have shown valuable properties. They are simple to prepare and analyse, the G(HC1) values are not sensitive to normal impurities and are constant within the dose range of interest for processing. This paper describes the experiments performed with 10 MeV pulsed electrons from the linear accelerator of the Research Establishment Riso, Denmark (7 microsecond pulses repeated 300 times per second, 10{sup 9} rad/sec in the pulse). The irradiations were calibrated calorimetrically. The G(HC1) values independent of dose up to 40 Mrad are given as a function of chlorobenzene concentration. The comparison with gamma irradiations shows only insignificant differences in the G-values. Above 10 vol. % chlorobenzene the G-values are approximately constant up to 20 Mrad or more, and are to within 2% equal to those obtained for gamma rays with free access of air. The addition of 0.04% of acetone or benzene to the systems had within the experimental error, no influence upon the G(HC1). The results show the applicability of ethanol-chlorobenzene dosimeters to the dosimetry of electron beam irradiations at dose rates as high as 10{sup 9} rad/sec and dosages up to 6 Mrad. (author)

  4. Neutron-induced charged-particle emission studies below 100 MeV at WNR

    Energy Technology Data Exchange (ETDEWEB)

    Haight, R.C.; Lee, T.M.; Sterbenz, S.M. [and others

    1994-07-01

    Charged-particles produced by neutron bombardment of selected targets with Z=5 through 53 have been studied for neutron energies from 1 MeV to about 100 MeV using the spallation neutron source at WNR/LAMPF. Particle detection with energy measurement and particle identification is accomplished by two-element {Delta}E-E counters, three-element {Delta}E{sub l}-{Delta}E{sub 2}-E counters or with pulse-shape discrimination using scintillators directly in the neutron beam. The experimental techniques for these measurements are described and comparisons made among the different approaches. This presentation introduces five papers contributed to this conference.

  5. Neutron-induced charged-particle emission studies below 100 MeV at WNR

    International Nuclear Information System (INIS)

    Haight, R.C.; Lee, T.M.; Sterbenz, S.M.

    1994-01-01

    Charged-particles produced by neutron bombardment of selected targets with Z=5 through 53 have been studied for neutron energies from 1 MeV to about 100 MeV using the spallation neutron source at WNR/LAMPF. Particle detection with energy measurement and particle identification is accomplished by two-element ΔE-E counters, three-element ΔE l -ΔE 2 -E counters or with pulse-shape discrimination using scintillators directly in the neutron beam. The experimental techniques for these measurements are described and comparisons made among the different approaches. This presentation introduces five papers contributed to this conference

  6. Dosimetric assessment of the PRESAGE dosimeter for a proton pencil beam

    International Nuclear Information System (INIS)

    Wuu, C-S; Qian, X; Xu, Y; Adamovics, J; Cascio, E; Lu, H-M

    2013-01-01

    The objective of this study is to assess the feasibility of using PRESAGE dosimeters for proton pencil beam dosimetry. Two different formulations of phantom materials were tested for their suitability in characterizing a single proton pencil beam. The dosimetric response of PRESAGE was found to be linear up to 4Gy. First-generation optical CT scanner, OCTOPUS TM was used to implement dose distributions for proton pencil beams since it provides most accurate readout. Percentage depth dose curves and beam profiles for two proton energy, 110 MeV, and 93 MeV, were used to evaluate the dosimetric performance of two PRESAGE phantom formulas. The findings from this study show that the dosimetric properties of the phantom materials match with basic physics of proton beams.

  7. MeV energy electron beam induced damage in isotactic polypropylene

    Energy Technology Data Exchange (ETDEWEB)

    Mathakari, N.L.; Bhoraskar, V.N. [Microtron Accelerator Laboratory, Department of Physics, University of Pune, Pune 411007 (India); Dhole, S.D. [Microtron Accelerator Laboratory, Department of Physics, University of Pune, Pune 411007 (India)], E-mail: sanjay@physics.unipune.ernet.in

    2008-06-15

    A few thin films of isotactic polypropylene were irradiated with 6 MeV energy electrons, in the fluence range from 5 x 10{sup 14} to 2 x 10{sup 15} electrons/cm{sup 2}. The structural, optical and mechanical properties were characterized by techniques such as FTIR, UV-vis, XRD, SEM, hardness and contact angle measurements. The FTIR spectra indicate that C-H and C-C bonds are scissioned and an isotactic arrangement of chains is partially destroyed. Moreover, the new carbonyl groups (C=O) are observed, which signifies oxidation. The UV-vis spectra shows a red shift in the absorption edge from pristine value of 240 to 380 nm, which corresponds to decrease in the optical band gap from 5.17 to 3.27 eV. This is because of the formation of conjugated double bonds as well as carbonization. The crystalline properties were analysed using XRD and it shows no profound change. This result may attribute that the radiation-induced changes have probably occurred to a large extent in amorphous regions. However, surface morphology by SEM and contact angle measurements showed considerable surface roughening, which indicates an uneven evolution of gases from the surface. Interestingly, the surface hardness of the films was found to increase with fluence and it may be due to crosslinking and carbonization on the surface. Overall, in conclusion this study shows considerable modifications in the physicochemical properties of isotactic polypropylene irradiated by 6 MeV energy pulsed electrons.

  8. Monte-Carlo calculations of forward directed bremsstrahlung produced by 20 and 45 MeV electrons on tungsten

    International Nuclear Information System (INIS)

    Goosman, D.R.

    1983-01-01

    The SANDYL Monte-Carlo code has been used to calculate the Bremsstrahlung photon production from beams of parallel electrons incident upon three target geometries. These are 20 MeV electrons onto 1 mm of tungsten + 59 mm of Be, which simulates the operating parameters of the FXR electron accelerator at LLNL Bldg. 801, 45 MeV electrons onto 1 mm of tungsten, and finally 45 MeV electrons onto 1 mm of tungsten and 147 mm of Be. The latter two situations simulate possible future modifications to the FXR accelerator. Graphs of the spectral shape of the Bremsstrahlung photons emitted with angles between 0 0 and 1 0 to the electron direction, the angular distribution of photon-MeV, and the dose reduction curves for each of the three geometries are given. The latter dose reduction curves allow one to calculate forward-directed photon fluxes in real-life situations where the electron beam has non-zero angular divergence

  9. Entanglement witnesses arising from exposed positive linear maps

    OpenAIRE

    Ha, Kil-Chan; Kye, Seung-Hyeok

    2011-01-01

    We consider entanglement witnesses arising from positive linear maps which generate exposed extremal rays. We show that every entanglement can be detected by one of these witnesses, and this witness detects a unique set of entanglement among those. Therefore, they provide a minimal set of witnesses to detect all entanglement in a sense. Furthermore, if those maps are indecomposable then they detect large classes of entanglement with positive partial transposes which have nonempty relative int...

  10. Electron beam accelerator facilities at IPEN-CNEN/SP

    Energy Technology Data Exchange (ETDEWEB)

    Somessari, Samir L.; Silveira, Carlos G. da; Paes, Helio; Somessari, Elizabeth S.R. [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)], E-mail: somessar@ipen.br

    2007-07-01

    Electron beam processing is a manufacturing technique, which applies a focused beam of high-energy electrons produced by an electron accelerator to promote chemical changes within a product. At IPEN-CNEN/SP there are two electron beam accelerators Type Dynamitron{sup R} (manufactured by RDI- Radiation Dynamics Inc.) Job 188 and Job 307 models. The technical specifications for the Job 188 energy 1.5 MeV, beam current 25 mA, scan 1.20 m, beam power 37.5 kW and for the Job 307 energy 1.5 MeV, beam current 65 mA, Scan 1.20 m, beam power 97.5 kW. Some applications of the electron beam accelerator for radiation processing are wire and cable insulation crosslinking, rubber vulcanization, sterilization and disinfection of medical products, food preservation, heat shrinkable products, polymer degradation, aseptic packaging, semiconductors and pollution control. For irradiating these materials at IPEN-CNEN/SP, there are some equipment such as, underbeam capstan with speed control from 10 to 700 m/min; a track; a system to roll up and unroll wires and electric cables, polyethylene blankets and other systems to improve the quality of the products. (author)

  11. Failure modes of composite sandwich beams

    OpenAIRE

    Gdoutos E.; Daniel I.M.

    2008-01-01

    A thorough investigation of failure behavior of composite sandwich beams under three-and four-point bending was undertaken. The beams were made of unidirectional carbon/epoxy facings and a PVC closed-cell foam core. The constituent materials were fully characterized and in the case of the foam core, failure envelopes were developed for general two-dimensional states of stress. Various failure modes including facing wrinkling, indentation failure and core failure were observed and compared wit...

  12. Calorimetric determination of electron beam output

    Energy Technology Data Exchange (ETDEWEB)

    Novotny, J; Kovar, Z; Jandejsek, L [Ceskoslovenska Akademie Ved, Prague. Ustav Radiologicke Dozimetrie

    1979-07-01

    Two types of portable graphite calorimeter are described having modified replaceable absorbers allowing measurements of energy flux density in betatron electron beams in a range of 4 to 50 MeV. In a range of 4 to 20 MeV the total measurement error was about 1%. The results are discussed of the standardization of Siemens and Ostron medical betatrons using the said calorimeters.

  13. A neutron beam facility at Spiral-2

    Energy Technology Data Exchange (ETDEWEB)

    Ledoux, X.; Bauge, E.; Belier, G.; Ethvignot, T.; Taieb, J.; Varignon, C. [CEA Bruyeres-le-Chatel, DIF, 91 (France); Andriamonje, S.; Dore, D.; Dupont, E.; Gunsing, F.; Ridikas, D.; Takibayev, A. [CEA Saclay, DSM/IRFU/SPhN, 91 - Gif-sur-Yvette (France); Blideanu, V. [CEA Saclay, DSM/IRFU/Senac, 91 - Gif-sur-Yvette (France); Aiche, M.; Barreau, G.; Czajkowski, S.; Jurado, B. [Centre d' Etudes Nucleaires de Bordeaux Gradignan, 33 (France); Ban, G.; Lecolley, F.R.; Lecolley, J.F.; Lecouey, J.L.; Marie, N.; Steckmeyer, J.C. [LPC, 14 - Caen (France); Dessagne, P.; Kerveno, M.; Rudolf, G. [IPHC, 57 - Strasbourg (France); Bem, P.; Mrazek, J.; Novak, J. [NPI, Rez (Czech Republic); Blomgren, J.; Pomp, S. [Uppsala Univ., Dept. of Physics and Astronomy (Sweden); Fischer, U.; Herber, S.; Simakov, S.P. [FZK, Karlsruhe (Germany); Jacquot, B.; Rejmund, F. [GANIL, 14 - Caen (France); Avrigeanu, M.; Avrigeanu, V.; Borcea, C.; Negoita, F.; Petrascu, M. [NIPNE, Bucharest (Romania); Oberstedt, S.; Plompen, A.J.M. [JRC/IRMM, Geel (Belgium); Shcherbakov, O. [PNPI, Gatchina (Russian Federation); Fallot, M. [Subatech, 44 - Nantes (France); Smith, A.G.; Tsekhanovich, I. [Manchester Univ., Dept. of Physics and Astronomy (United Kingdom); Serot, O.; Sublet, J.C. [CEA Cadarache, DEN, 13 - Saint-Paul-lez-Durance (France); Perrot, L.; Tassan-Got, L. [IPNO, 91 - Orsay (France); Caillaud, T.; Giot, L.; Landoas, O.; Ramillon, J.M.; Rosse, B.; Thfoin, I. [CIMAP, 14 - Caen (France); Balanzat, E.; Bouffard, S.; Guillous, S.; Oberstedt, A. [Orebro Univ. (Sweden)

    2009-07-01

    The future Spiral-2 facility, dedicated to the production of intense radioactive ion beams, is based on a high-power superconducting driver Linac, delivering high-intensity deuteron, proton and heavy ion beams. These beams are particularly well suited to the production of neutrons in the 100 keV- 40 MeV energy range, a facility called 'Neutrons for Science' (NFS) will be built in the LINAG Experimental Area (LEA). NFS, operational in 2012, will be composed of a pulsed neutron beam for in-flight measurements and irradiation stations for activation measurements and material studies. Thick C and Be converters and a deuteron beam will produce an intense continuous neutron spectrum, while a thin {sup 7}Li target and a proton beam allow to generate quasi-mono-energetic neutrons. In the present work we show how the primary ion beam characteristics (energy, time resolution and intensity) are adequate to create a neutron time-of-flight facility delivering intense neutron fluxes in the 100 keV-40 MeV energy range. Irradiation stations for neutron, proton and deuteron reactions will also allow to perform cross-section measurements by means of the activation technique. Light-ion beams will be used to study radiation damage effects on materials for the nuclear industry. (authors)

  14. Production of slow-positron beams with an electron linac

    International Nuclear Information System (INIS)

    Howell, R.H.; Alvarez, R.A.; Stanek, M.

    1982-01-01

    Intense, pulsed beams of low-energy positrons have been produced by a high-energy beam from an electron linac. The production efficiency for low-energy positrons has been determined for electrons with 60 to 120 MeV energy, low-energy positron beams from a linac can be of much higher intensity than those beams currently derived from radioactive sources

  15. Clinical meaning of radiodermatitis considering the surface dose of supervoltage electron beam

    Energy Technology Data Exchange (ETDEWEB)

    Hiraki, T [Kanazawa Univ. (Japan). School of Paramedicine; Rikimaru, S; Kakishita, M; Kuranishi, M

    1975-12-01

    In our experience using supervoltage betatron electron beam, the skin surface dose of the electron decreased when the energy became either greater or less than 18 MeV. When we considered 18 MeV to be a 100% dose, the dose with 4 MeV, which was the least amount, corresponded to 81% of the dose. The skin surface dose of 10 MeV betatron electrons or more became greater than the 90% standard tumor dose. An external irradiation of more than 10 MeV should not be applied to neoplasms of which the curative ratio is less than 1.0. Therefore another methods such as intraoperative irradiation, should be used. The surface skin dose about 4 to 6 MeV betatron postoperative irradiation, particularly after resection of breast cancer, was less than the skin dose with 10 MeV. Close care should be taken to prevent hot lesions which are caused by duplication of irradiation fields. It should be kept in mind that the late effects of hot lesions caused by electron beam irradiation with an energy of 10 MeV or more are serious.

  16. RI beam factory and its expected pioneering work

    International Nuclear Information System (INIS)

    Yano, Yasushige

    1996-01-01

    The RARF (RIKEN Accelerator Research Facility) houses an intermediate-energy heavy-ion accelerator complex consisting of a K540-MeV ring cyclotron (RRC) and a couple of different types of the injectors: a variable-frequency heavy-ion linac and a K70-MeV AVF cyclotron. One of remarkable features of this facility is capability of supplying light-atomic-mass RI (radioactive isotope) beams with the world-highest level of intensities by the projectile-fragment separator, RIPS. In these several years nuclear physicists have opened up a quite new and fascinating heavy-ion science exploiting such RI beams. In order to further promote this new science, the RARF proposes 'RIKEN RI Beam Factory' as a next facility-expanding project. The factory takes the aim at providing RI beams covering over the whole atomic-mass range with the world-highest intensities in a wide energy range up to several hundreds MeV/nucleon. To realize the 'Factory' a K2500-MeV superconducting ring cyclotron will be built which boosts output energies of the RRC beams up to 400 MeV/nucleon for light ions and up to 100 MeV/nucleon for very heavy ions, preserving their beam intensities (typically 1 pμA). RI beams will be generated by the projectile fragmentation. A new type of experimental installation called 'MUSES' (Multi-USe Experimental Storage rings) will also be constructed. It consists of an accumulator-cooler ring, booster synchrotron ring and double storage rings. With MUSES, various types of unique colliding experiments will become possible: ion-ion merging or head-on collisions; collisions of either electrons or X-rays with ion (stable isotope or RI) beams; internal target experiments; and atomic and molecular physics with cooler electron beams. (author)

  17. Analysing power for neutron-proton scattering at 14.1 MeV

    International Nuclear Information System (INIS)

    Brock, J.E.; Chisholm, A.; Duder, J.C.; Garrett, R.; Poletti, J.L.

    1981-01-01

    The analysing power Asub(y)(theta) for neutron-proton scattering has been measured at 14.1 MeV for c.m. angles between 50 0 and 157 0 . A polarized neutron beam was produced by the reaction 3 H(d,n) 4 He at 110 keV, using polarized deuterons from an atomic beam polarized ion source. Liquid and plastic scintillators were used for proton targets and the scattered particles were detected in an array of platic scintillators. Use of the associated alpha technique, multi-parameter recording of events and off-line computer treatment led to very low backgrounds. The results differ significantly from the predictions of the phase-shift analyses of Yale IV, Livermore X and Arndt et al. We find, however, excellent agreement with the predictions of the Paris potential of Lacombe et al. Existing n-p analysing power results up to 30 MeV are surveyed and found to be consistent. An attempt was made to look for an isospin splitting of the triplet P-wave phase shifts. (orig.)

  18. High-energy electron beams for ceramic joining

    Science.gov (United States)

    Turman, Bob N.; Glass, S. J.; Halbleib, J. A.; Helmich, D. R.; Loehman, Ron E.; Clifford, Jerome R.

    1995-03-01

    Joining of structural ceramics is possible using high melting point metals such as Mo and Pt that are heated with a high energy electron beam, with the potential for high temperature joining. A 10 MeV electron beam can penetrate through 1 cm of ceramic, offering the possibility of buried interface joining. Because of transient heating and the lower heat capacity of the metal relative to the ceramic, a pulsed high power beam has the potential for melting the metal without decomposing or melting the ceramic. We have demonstrated the feasibility of the process with a series of 10 MeV, 1 kW electron beam experiments. Shear strengths up to 28 MPa have been measured. This strength is comparable to that reported in the literature for bonding silicon nitride (Si3N4) to molybdenum with copper-silver-titanium braze, but weaker than that reported for Si3N4 - Si3N4 with gold-nickel braze. The bonding mechanism appears to be formation of a thin silicide layer. Beam damage to the Si3N4 was also assessed.

  19. Elastic Neutron Scattering at 96 MeV from {sup 12}C and {sup 208}Pb

    Energy Technology Data Exchange (ETDEWEB)

    Klug, J.; Blomgren, J.; Atac, A. [and others

    2003-04-01

    A facility for detection of scattered neutrons in the energy interval 50-130 MeV, SCANDAL (SCAttered Nucleon Detection AssembLy), has recently been installed at the 20-180 MeV neutron beam line of the The Svedberg Laboratory, Uppsala. Elastic neutron scattering from {sup 12}C and {sup 208}Pb has been studied at 96 MeV in the 10-70 deg interval. The achieved energy resolution, 3.7 MeV, is about an order of magnitude better than for any previous experiment above 65 MeV incident energy. The present experiment represents the highest neutron energy where the ground state has been resolved from the first excited state in neutron scattering. A novel method for normalization of the absolute scale of the cross section has been used. The estimated uncertainty, 3 %, is unprecedented for a neutron-induced differential cross section measurement on a nuclear target. The results are compared with modern optical model predictions, based on phenomenology or microscopic nuclear theory.

  20. Celebrity witnessing

    DEFF Research Database (Denmark)

    Christiansen, Lene Bull; Frello, Birgitta

    2016-01-01

    This article deals with emotional address in the narrative modality of celebrity witnessing in the marketing of development aid. We analyse Danish celebrity narratives of global caring, drawing on Luc Boltanski’s work on a ‘politics of pity’, Lilie Chouliaraki’s notion of the ‘aspirational discou...

  1. Experimental validation of the DPM Monte Carlo code using minimally scattered electron beams in heterogeneous media

    International Nuclear Information System (INIS)

    Chetty, Indrin J.; Moran, Jean M.; Nurushev, Teamor S.; McShan, Daniel L.; Fraass, Benedick A.; Wilderman, Scott J.; Bielajew, Alex F.

    2002-01-01

    A comprehensive set of measurements and calculations has been conducted to investigate the accuracy of the Dose Planning Method (DPM) Monte Carlo code for electron beam dose calculations in heterogeneous media. Measurements were made using 10 MeV and 50 MeV minimally scattered, uncollimated electron beams from a racetrack microtron. Source distributions for the Monte Carlo calculations were reconstructed from in-air ion chamber scans and then benchmarked against measurements in a homogeneous water phantom. The in-air spatial distributions were found to have FWHM of 4.7 cm and 1.3 cm, at 100 cm from the source, for the 10 MeV and 50 MeV beams respectively. Energy spectra for the electron beams were determined by simulating the components of the microtron treatment head using the code MCNP4B. Profile measurements were made using an ion chamber in a water phantom with slabs of lung or bone-equivalent materials submerged at various depths. DPM calculations are, on average, within 2% agreement with measurement for all geometries except for the 50 MeV incident on a 6 cm lung-equivalent slab. Measurements using approximately monoenergetic, 50 MeV, 'pencil-beam'-type electrons in heterogeneous media provide conditions for maximum electronic disequilibrium and hence present a stringent test of the code's electron transport physics; the agreement noted between calculation and measurement illustrates that the DPM code is capable of accurate dose calculation even under such conditions. (author)

  2. Design of the ITER Neutral Beam injectors

    International Nuclear Information System (INIS)

    Hemsworth, R.S.; Feist, J.; Hanada, M.; Heinemann, B.; Inoue, T.; Kuessel, E.; Kulygin, V.; Krylov, A.; Lotte, P.; Miyamoto, K.; Miyamoto, N.; Murdoch, D.; Nagase, A.; Ohara, Y.; Okumura, Y.; Pamela, J.; Panasenkov, A.; Shibata, K.; Tanii, M.

    1996-01-01

    This paper describes the Neutral Beam Injection system which is presently being designed in Europe, Japan and Russia, with co-ordination by the Joint Central Team of ITER at Naka, Japan. The proposed system consists of three negative ion based neutral injectors, delivering a total of 50 MW of 1 MeV D 0 to the ITER plasma for pulse length of ≥1000 s. The injectors each use a single caesiated volume arc discharge negative ion source, and a multi-grid, multi-aperture accelerator, to produce about 40 A of 1 MeV D - . This will be neutralized in a sub-divided gas neutralizer, which has a conversion efficiency of about 60%. The charged fraction of the beam emerging from the neutralizer is dumped in an electrostatic residual ion dump. A water cooled calorimeter can be moved into the beam path to intercept the neutral beam, allowing commissioning of the injector independent of ITER. copyright 1996 American Institute of Physics

  3. Study of inclusive proton spectra from 20 MeV deuteron breakup by bismuth

    International Nuclear Information System (INIS)

    Badiger, N.M.; Hallur, B.R.; Madhusoodhanan, T.; Sathyavathiamma, M.P.; Puttaswamy, N.G.; Darshan, V.P.; Sharma, H.; Chintalapudi, S.N.

    1997-01-01

    The breakup of deuteron into proton and neutron has been studied earlier to understand the breakup mechanism. Inclusive measurements show the expected broad bumps near the beam velocity. In the present experiment, the breakup of 20 MeV deuterons by bismuth target has been investigated

  4. Electron trapping and acceleration by the plasma wakefield of a self-modulating proton beam

    CERN Document Server

    Lotov, K.V.; Petrenko, A.V.; Amorim, L.D.; Vieira, J.; Fonseca, R.A.; Silva, L.O.; Gschwendtner, E.; Muggli, P.

    2014-01-01

    It is shown that co-linear injection of electrons or positrons into the wakefield of the self-modulating particle beam is possible and ensures high energy gain. The witness beam must co-propagate with the tail part of the driver, since the plasma wave phase velocity there can exceed the light velocity, which is necessary for efficient acceleration. If the witness beam is many wakefield periods long, then the trapped charge is limited by beam loading effects. The initial trapping is better for positrons, but at the acceleration stage a considerable fraction of positrons is lost from the wave. For efficient trapping of electrons, the plasma boundary must be sharp, with the density transition region shorter than several centimeters. Positrons are not susceptible to the initial plasma density gradient.

  5. Thermoluminescence response of Ge-, Al- and Nd- doped optical fibers by 6 MeV - electron and 6 MeV - photon irradiations

    International Nuclear Information System (INIS)

    Hossain, I.; Moburak, A. A.; Saeed, M.A.; Wagiran, H.; Hida, N.; Yaakob, H.N.

    2015-01-01

    In this paper, we report the prediction of thermoluminescence responses of Neodymium-doped SiO 2 optical fibre with various dose ranges from 0.5 Gy to 4.0 Gy by 6 MeV - electron irradiations without requirement for experimental measurements. A technique has been developed to calculate prediction of 6 MeV - electron response of Neodymium-doped SiO 2 optical fibre by observing the measured TL response of 6 MV - photon and the ratio of known measured photon/electron yield ratio distribution for Ge-doped, Al-doped optical fibre and standard TLD 100 dosimeter. The samples were kept in gelatin capsule an irradiated with 6 MV - photon at the dose range from 0.5 Gy to 4.0 Gy. Siemens model Primus 3368 linear accelerator located at Hospital Sultan Ismail, Johor Bahru has been used to deliver the photon beam to the samples. We found the average response ratio of 6 MV - photon and 6 MeV - electron in Ge-doped, Al-doped optical fibre and standard TLD-100 dosimeter are 0.83(3). Observing the measured value of 6 MV - photon irradiation this average ratio is useful to find the prediction of thermoluminescence responses by 6 MeV - electron irradiation of Neodymium-doped SiO 2 optical fibre by the requirement for experimental measurements with various dose ranges from 0.5 Gy to 4.0 Gy by 6 MV - photon irradiations.

  6. 29 CFR 18.701 - Opinion testimony by lay witnesses.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 1 2010-07-01 2010-07-01 true Opinion testimony by lay witnesses. 18.701 Section 18.701 Labor Office of the Secretary of Labor RULES OF PRACTICE AND PROCEDURE FOR ADMINISTRATIVE HEARINGS... Opinion testimony by lay witnesses. If the witness is not testifying as an expert, the witness' testimony...

  7. Energy dependence of EBT-1 radiochromic film response for photon (10 kVp-15 MVp) and electron beams (6-18 MeV) readout by a flatbed scanner

    International Nuclear Information System (INIS)

    Richter, Christian; Pawelke, Joerg; Karsch, Leonhard; Woithe, Julia

    2009-01-01

    Purpose: The aim of this article is to investigate the energy dependence of the radiochromic film type, Gafchromic EBT-1, when scanned with a flatbed scanner for film readout. Methods: Dose response curves were determined for 12 different beam qualities ranging from a 10 kVp x-ray beam to a 15 MVp x-ray beam and include also two high energy electron beam qualities (6 and 18 MeV). The dose responses measured as net optical density (netOD) for the different beam qualities were normalized to the response of a reference beam quality (6 MVp). Results: A strong systematic energy dependence of the film response was found. The lower the effective beam energy, the less sensitive the EBT-1 films get. The maximum decrease in dose for the same film response between the 25 kVp and 6 MVp beam qualities was 44%. Additionally, a difference in energy dependence for different doses was discovered, meaning that higher doses show a smaller dependency on energy than lower doses. The maximum decrease in the normalized netOD was found to be 25% for a dose of 0.5 Gy relative to the normalized netOD for 10 Gy. Moreover, a scaling procedure is introduced, allowing the correction of the energy dependence for the investigated beam qualities and also for comparable x-ray beam qualities within the energy range studied. Conclusions: A strong energy dependence for EBT-1 radiochromic films was found. The films were readout with a flatbed scanner. If the effective beam energy is known, the energy dependence can be corrected with the introduced scaling procedure. Further investigation of the influence of the spectral band of the readout device on energy dependence is needed to understand the reason for the different energy dependences found in this and previous works.

  8. 12 MeV, 4.3 kW electron linear accelerator irradiation application

    International Nuclear Information System (INIS)

    Hang Desheng; Lai Qiji

    2000-01-01

    Characteristics of an electron linear accelerator, which has 6-12 MeV energy, 4.2 kW average beam power is introduced. Results show that it has advantages on improving the characteristics of semiconductor devices such as diodes, triodes, SCR, preventing garlic from sprout, preservation of food, and so on

  9. Differential production cross sections for charged particles produced by 590 MeV proton bombardment of thin metal targets

    International Nuclear Information System (INIS)

    Howe, S.D.; Cierjacks, S.; Hino, Y.; Raupp, F.; Rainbow, M.T.; Swinhoe, M.T.; Buth, L.

    1981-01-01

    Differential production cross sections have been measured for the reactions (p,p), (p,d), (p,t) and (p,π+-) using the 590 MeV proton beam at SIN. Here we report measurements made on thin targets of aluminium, niobium, lead, and uranium at laboratory angles of 90 0 and 157 0 . The data were taken over a proton energy range of about 50 MeV to 590 MeV. Differential cross sections are reported along with predictions by the intranuclear-cascade/evaporation model as computed by HETC. (orig.)

  10. Ion shaking in the 200 MeV XLS-ring

    International Nuclear Information System (INIS)

    Bozoki, E.; Kramer, S.L.

    1992-01-01

    It has been shown that ions, trapped inside the beam's potential, can be removed by the clearing electrodes when the amplitude of the ion oscillation is increased by vertically shaking the ions. We will report on a similar experiment in the 200 Mev XLS ring. The design of the ion clearing system for the ring and the first results obtained, were already reported. In the present series of experiments, RF voltage was applied on a pair of vertical strip-lines. The frequency was scanned in the range of the ion (from H 2 to CO 2 ) bounce frequencies in the ring (1--10 MHz). The response of the beam size, vertical betatron tune and lifetime was studied

  11. (n, Xn) cross sections measurements at 96 MeV

    International Nuclear Information System (INIS)

    Sagrado Garcia, Inmaculada C.

    2006-01-01

    Nucleon induced reactions in the 20-200 MeV energy range are intensively studied since a long time. The evaporation and the pre-equilibrium processes correspond to an important contribution of the production cross section in these reactions. Several theoretical approaches have been proposed and their predictions must be tested. The experimental results shown in this work are the only complete set of data for the (n, Xn) reactions in this energy range. Neutron double differential cross sections measurements using lead and iron targets for an incident neutron beam at 96 MeV were carried out at TSL laboratory, in Uppsala (Sweden). The measurements have been performed for the first time with an energy threshold of 2 MeV and for a wide angular range (15 deg.-98 deg.). Neutrons have been detected using two independent setups, DECOI and DEMON and CLODIA and SCANDAL, in order to cover the whole energy range (2-100 MeV). The angular distributions, the differential cross sections and the total inelastic production cross sections have been calculated using the double differential cross sections. The comparisons between the experimental data and the predictions given by two of the most popular simulation codes, GEANT3 and MCNPX, have been performed, as well as the comparison with the predictions of the microscopic simulation model DYWAN, selected for its original treatment of nucleon-nucleus reactions. (author) [fr

  12. Summary test results of the particle-beam diagnostics for the Advanced Photon Source (APS) subsystems

    International Nuclear Information System (INIS)

    Lumpkin, A.; Wang, X.; Sellyey, W.; Patterson, D.; Kahana, E.

    1994-01-01

    During the first half of 1994, a number of the diagnostic systems for measurement of the charged-particle beam parameters throughout the subsystems of the Advanced Photon Source (APS) have been installed and tested. The particle beams eventually will involve 450-MeV to 7-GeV positrons and with different pulse formats. The first test and commissionin results for beam profiles, beam position monitors, loss rate monitors, current monitors, and synchrotron radiation photon monitors hve been obtained using 200- to 350-MeV electron beams injected into the subsystems. Data presented are principally from the transport lines and the positron accumulator ring

  13. Test facility of proton beam utilization of the PEFP at the SNU-AMS tandem accelerator

    International Nuclear Information System (INIS)

    Kim, K. R.; Park, B. S.; Lee, H. R.

    2004-01-01

    The PEFP (Proton Engineering Frontier Project) will supply users with a 20-MeV proton beam by the middle of 2007. A survey on users' demand was performed to draw the concept for the 20-MeV user facilities and to investigate users' requirements. In the mean time, a 6-MeV test facility has been developed to give users opportunities to experiment with proton beams. That facility will be attached to the 3-MV tandem accelerator at Seoul National University.

  14. On scaling and optimization of high-intensity, low-beam-loss RF linacs for neutron source drivers

    International Nuclear Information System (INIS)

    Jameson, R.A.

    1992-01-01

    RF linacs providing cw proton beams of 30--250 mA at 800--1600 MeV, and cw deuteron beams of 100--250 mA at 35--40 MeV, are needed as drivers for factory neutron sources applied to radioactive waste transmutation, advanced energy production, materials testing facilities, and spallation neutron sources. The maintenance goals require very low beam loss along the linac. Optimization of such systems is complex; status of beam dynamics aspects presently being investigated is outlined

  15. Safety Tips from the Expert Witness.

    Science.gov (United States)

    Gray, Gary R.

    1995-01-01

    Many physical educators and coaches use the potential for liability to guide their decisions about conducting activities. By understanding expert witnesses' roles in negligence actions, surer planning, teaching, and coaching are possible. The paper describes issues that expert witnesses examine in negligence actions against physical educators,…

  16. Proton-nucleus interactions at 640 MeV accompanied by backward emission of energetic protons

    International Nuclear Information System (INIS)

    Komarov, V.I.; Kosarev, E.G.; Mueller, H.; Netzband, D.; Toneev, V.D.; Stiehler, T.; Tesch, S.; Gudima, K.K.; Mashnik, S.G.

    1979-03-01

    Spectra of protons of energies between 50 and 145 MeV emitted from carbon have been measured at angles from 105 0 to 160 0 with respect to the 640 MeV proton beam. The measurements have been carried out both inclusively and in coincidence with protons emitted at forward angles up to +- 40 0 with energies from 255 to 330 MeV. This energy interval has been chosen in accordance with the kinematics of quasifree scattering on two-nucleon groups. Inclusive differential cross sections at 140 0 and coincidence cross sections at the angle pair (-12 0 , 122 0 ) have also been measured with Be, Al, Cu and Pb targets. The data have been compared with the predictions of several models. (author)

  17. Corrosion of target and structural materials in water irradiated by an 800 MeV proton beam

    International Nuclear Information System (INIS)

    Butt, D.P.; Kanner, G.S.; Lillard, R.S.

    1996-01-01

    Radiation enhanced, aqueous corrosion of solid neutron-targets such as tungsten or tantalum, or target cladding or structural materials such as superalloys and stainless steels, is a significant concern in accelerator-driven transmutation technologies. In this paper we briefly describe our current methods for control and in situ monitoring of corrosion in accelerator cooling water loops. Using floating, electrochemical impedance spectroscopy (EIS), we have measured the corrosion rates of aluminum 6061, copper, Inconel 718, and 304L stainless steel in the flow loop of a water target irradiated by a μamp, 800 MeV proton beam. Impedance spectroscopy allows us to model the corrosion process of a material as an equivalent electrical circuit. Thus the polarization resistance, which is inversely proportional to the corrosion rate, can be extracted from the frequency response of a metal specimen. During a three month period, without the use of corrosion mitigation techniques, we observed increases of several orders of magnitude in the water conductivity and the corrosion rates. The increase in corrosion is at least partially attributed to a build up of peroxide in our pseudo-closed loop system. In this paper we also briefly describe our second generation experiments, scheduled to begin in late 1996. In these experiments we plan to measure the corrosion rates of tungsten, tantalum, Inconel 718, 316L and 304L stainless steel, HT-9 austenitic stainless steel, and aluminum 5053. Two or three electrode probes of each material are being placed directly in the proton beam, in a high neutron flux region, or a significant distance from the high radiation area. We will be measuring corrosion rates, changes in pH and conductivity, and we will be establishing parameters for filtration and mitigation of corrosion. We will also discuss our ideas for making in situ measurements of water radiolysis using optical and laser diagnostic techniques

  18. Simulations of beam trajectory for position target optimization of extraction system output beams cyclotron proton Decy-13

    International Nuclear Information System (INIS)

    Idrus Abdul Kudus; Taufik

    2015-01-01

    Positioning and track simulation beam the cyclotron Decy-13 for laying optimization the target system have been done using lorentz force function and scilab 5.4.1 simulation. Magnetic field and electric field is calculated using Opera3D/Tosca as a simulation input. Used radio frequency is 77.66 MHz with the amplitude voltage is 40 kV is obtained energy 13 MeV. The result showed that the coordinates of the laying of the target system in a vacuum chamber is located at x = -389 mm and y = 445 mm with the width of the output beam is 10 mm. The laying stripper position for the output in center target is located at x = -76 mm and y =416 mm from the center coordinate on the center of dee with the energy of proton is 13 MeV at the point of beam extraction carbon foil. The changes position laying is carried out on range x = -70; y = 424 mm until x = - 118; y = 374 mm result for shifting area stripper which is still capable of deflection the electron beam. (author)

  19. Measurement of {sup 232}Th(n, 5nγ) cross sections from 29 MeV to 42 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Kerveno, M.; Baumann, P.; Dessagne, P.; Rudolf, G. [Universite de Strasbourg, IPHC, Strasbourg (France); CNRS, UMR7178, Strasbourg (France); Nolte, R.; Reginatto, M. [Physikalisch-Technische Bundesanstalt, Braunschweig (Germany); Jericha, E. [Technische Universitaet Wien, Atominstitut, Wien (Austria); Jokic, S.; Lukic, S. [Vinca Institute of Nuclear Sciences, Belgrade (Serbia); Koning, A.J. [Nuclear Research and Consultancy Group, Petten (Netherlands); Meulders, J.P. [Institut de Physique Nucleaire, Louvain-la-Neuve (Belgium); Nachab, A. [Universite Cadi Ayyad, Departement de physique, Faculte Poly-disciplinaire de Safi, Safi (Morocco); Pavlik, A. [Faculty of Physics, University of Vienna, Wien (Austria)

    2014-10-15

    The excitation function of the reaction {sup 232} Th(n, 5nγ){sup 228} Th from 29 to 42 MeV has been measured for the first time at the quasi-monoenergetic neutron beam of the UCL cyclotron CYCLONE employing the {sup 7}Li(p,n) source reaction. Taking advantage of the good energy resolution of the planar High-Purity Germanium (HPGe) detectors, prompt γ-ray spectroscopy was used to detect the γ-rays resulting from the decay of excited states of nuclei created by the (n,xn) reactions. The neutron beam was characterized by a combination of time of flight measurements carried out using a liquid scintillation detector and a {sup 238}U fission ionization chamber. Fluence measurements were performed using a proton recoil telescope. The results are compared with TALYS-1.4 code calculations. (orig.)

  20. Dosimetric properties of the fast neutron therapy beams at TAMVEC

    International Nuclear Information System (INIS)

    Almond, P.R.; Smith, A.R.; Smathers, J.R.; Otte, V.A.

    1975-01-01

    In October 1972, M.D. Anderson Hospital and Tumor Institute of the University of Texas System Cancer Center initiated a clinical trial of fast neutron radiotherapy using the cyclotron at Texas A and M University. Initially, the study used neutrons produced by bombarding beryllium with 16 MeV deuterons, but since March, 1973, neutrons from 50 MeV deuterons have been used. The dosimetric properties of the 30 MeV beams have also been measured for comparison with the neutron beams from D-T generators. The three beams are compared in terms of dose rate, skin sparing, depth dose and field flatness. Isodose curves for treatment planning were generated using the decrement line method and compared to curves measured by a computer controlled isodose plotter. This system was also used to measure the isodose curves for wedge fields. Dosimetry checks on various patients were made using silicon diodes as in vivo fast neutron dosimeters

  1. Proposed particle-beam characterizations for the APS undulator test line

    Energy Technology Data Exchange (ETDEWEB)

    Lumpkin, A.H.; Borland, M.; Milton, S.

    1993-09-01

    A research and development effort is underway at the Advanced Photon Source (APS) to use an rf gun as a low-emittance electron source for injection into the 100- to 650-MeV linac subsystem and subsequently to an undulator test area. This configuration would combine the acceleration capability of the 200-MeV S-band electron linac and the in-line 450-MeV positron linac that normally provide positrons to the positron accumulator ring (PAR). A transport line that bypasses the PAR will bring the electrons to the undulator test area. Characterization techniques will be discussed for the electron beam with a normalized, rms emittance of <10 {pi} mm mrad (1{sigma}) at micropulse charges of up to 350 pC and micropulse durations of {approximately}5 ps (FWHM). Tests proposed include measurement of particle beam transport effects (at one-tenth the storage ring beam rigidity) caused by small undulator field errors as well as operations intended to produce coherent, short wavelength radiation (<200 nm).

  2. Polypropylene compositional evolution under 3.5 MeV He+ ion irradiation

    International Nuclear Information System (INIS)

    Abdesselam, M.; Muller, D.; Djebara, M.; Chami, A.C.; Montgomery, P.

    2012-01-01

    A helium beam at 3.5 MeV was used to induce damage in thin polypropylene film of 5.1 μm in thickness. The fluence ranges from 2 × 10 12 to 3.5 × 10 15 cm −2 . The evolution of the atomic composition (C and H) as a function of the fluence was investigated in situ by forward elastic scattering (C(α, α)C) and hydrogen elastic recoil detection (H(α, H)α), respectively. The helium beam was used at the same time for irradiation and analysis. In respect to the high sensitivity of the polypropylene to radiation damage, the beam current was kept at very low intensity of 0.5 nA. The mass loss becomes significant above a fluence of ∼5 × 10 13 He + cm −2 . The carbon depletion levels off at a fluence of ∼5 × 10 14 He + cm −2 approximately while hydrogen loss continues to be present along the whole of the studied fluence range. The final carbon and hydrogen losses, at the highest fluence, are around 17% and 48% of their initial contents, respectively. Satisfactory fits to the release curves have been obtained in the framework of the bulk molecular recombination model (BMR). The deduced hydrogen and carbon release cross sections are 7.8 and 65.2 × 10 −16 cm 2 , respectively. A comparison with our previous measurements of polyethylene terephthalate (PET) film irradiated with 3.7 MeV He + beam is made.

  3. Photoneutron source based on a compact 10 MeV betatron

    International Nuclear Information System (INIS)

    Bell, Z.W.; Chaklov, V.L.; Golovkov, V.M.

    1998-01-01

    Accelerator-based photoneutron sources have enjoyed wide use and offer the advantages of long term stability, ease of control and absence of radioactive materials. The authors report here measurements of the yield of photoneutrons from a neutron generator using a compact betatron (466 kg total weight, 900 by 560 by 350 mm betatron dimensions) at the Institute of Introscopy of the Tomsk Polytechnic University. Electrons were accelerated to energies up to 10 MeV and produced a bremsstrahlung beam with a dose rate of 0.16 Gy/min (at 10 MeV, 1 meter from the bremsstrahlung target) to irradiate LiD, Be, depleted U, and Pb neutron-producing targets. The angular distributions of photoneutrons produced by bremsstrahlung beams were measured with a long counter and integrated to determine neutron yield. In addition, neutron time of flight spectra were recorded from all targets using a 15 meter flight path perpendicular to the photon beam. The maximum observed yields were 5.2 x 10 4 n/rad/gram target obtained with LiD, 1.7 x 10 4 n/rad/gram from Be, 3.3 x 10 3 n/rad/gram from U, and 7.5 x 10 2 n/rad/gram from Pb. Optimization of target dimensions, shape, and positioning is expected to increase the yield from the LiD target by a factor of 35. With the increased yield, this compact betatron-based system could find application in the interrogation of waste containers for fissile material

  4. Results of a first round 150 MeV nu/sub μ/ oscillation experiment and implications for future LAMPF experiments

    International Nuclear Information System (INIS)

    Cortez, B.; LoSecco, J.; Sulak, L.; Soukas, A.; Weng, W.

    1981-01-01

    We report on a sensitive search for neutrino oscillation. A pure nu/sub μ/ beam of low energy was constructed at the Brookhaven AGS. The appearance of any nu/sub e/ in the beam would signify oscillations. To maximize sensitivity the energy of the neutrino beam was reduced to 150 MeV. The existing neutrino beam line and a 30T liquid scintillation calorimeter used in previous nu p scattering experiments were utilized

  5. Beam dynamics simulation of the Spallation Neutron Source linear accelerator

    International Nuclear Information System (INIS)

    Takeda, H.; Billen, J.H.; Bhatia, T.S.

    1998-01-01

    The accelerating structure for Spallation Neutron Source (SNS) consists of a radio-frequency-quadrupole-linac (RFQ), a drift-tube-linac (DTL), a coupled-cavity-drift-tube-linac (CCDTL), and a coupled-cavity-linac (CCL). The linac is operated at room temperature. The authors discuss the detailed design of linac which accelerates an H - pulsed beam coming out from RFQ at 2.5 MeV to 1000 MeV. They show a detailed transition from 402.5 MHz DTL with a 4 βλ structure to a CCDTL operated at 805 MHz with a 12 βλ structure. After a discussion of overall feature of the linac, they present an end-to-end particle simulation using the new version of the PARMILA code for a beam starting from the RFQ entrance through the rest of the linac. At 1000 MeV, the beam is transported to a storage ring. The storage ring requires a large (±500-keV) energy spread. This is accomplished by operating the rf-phase in the last section of the linac so the particles are at the unstable fixed point of the separatrix. They present zero-current phase advance, beam size, and beam emittance along the entire linac

  6. SU-C-201-07: Towards Clinical Cherenkov Emission Dosimetry: Stopping Power-To-Cherenkov Power Ratios and Beam Quality Specification of Clinical Electron Beams

    International Nuclear Information System (INIS)

    Zlateva, Y; Seuntjens, J; El Naqa, I

    2016-01-01

    Purpose: We propose a Cherenkov emission (CE)-based reference dosimetry method, which in contrast to ionization chamber-based dosimetry, employs spectrum-averaged electron restricted mass collision stopping power-to-Cherenkov power ratios (SCRs), and we examine Monte Carlo-calculated SCRs and beam quality specification of clinical electron beams. Methods: The EGSnrc user code SPRRZnrc was modified to compute SCRs instead of stopping-power ratios (single medium: water; cut-off: CE threshold (observing Spencer-Attix conditions); CE power: Frank-Tamm). SCRs are calculated with BEAMnrc for realistic electron beams with nominal energies of 6–22 MeV from three Varian accelerators (TrueBeam Clinac 21EX, Clinac 2100C/D) and for mono-energetic beams of energies equal to the mean electron energy at the water surface. Sources of deviation between clinical and mono-energetic SCRs are analyzed quantitatively. A universal fit for the beam-quality index R_5_0 in terms of the depth of 50% CE C_5_0 is carried out. Results: SCRs at reference depth are overestimated by mono-energetic values by up to 0.2% for a 6-MeV beam and underestimated by up to 2.3% for a 22-MeV beam. The variation is mainly due to the clinical beam spectrum and photon contamination. Beam angular spread has a small effect across all depths and energies. The influence of the electron spectrum becomes increasingly significant at large depths, while at shallow depths and high beam energies photon contamination is predominant (up to 2.0%). The universal data fit reveals a strong linear correlation between R_5_0 and C_5_0 (ρ > 0.99999). Conclusion: CE is inherent to radiotherapy beams and can be detected outside the beam with available optical technologies, which makes it an ideal candidate for out-of-beam high-resolution 3D dosimetry. Successful clinical implementation of CE dosimetry hinges on the development of robust protocols for converting measured CE to radiation dose. Our findings constitute a key step

  7. Intense ion beam generator

    International Nuclear Information System (INIS)

    Humphries, S. Jr.; Sudan, R.N.

    1977-01-01

    Methods and apparatus for producing intense megavolt ion beams are disclosed. In one embodiment, a reflex triode-type pulsed ion accelerator is described which produces ion pulses of more than 5 kiloamperes current with a peak energy of 3 MeV. In other embodiments, the device is constructed so as to focus the beam of ions for high concentration and ease of extraction, and magnetic insulation is provided to increase the efficiency of operation

  8. The clinical meaning of radiodermatitis considering the surface dose of supervoltage electron beam

    International Nuclear Information System (INIS)

    Hiraki, Tatsunosuke; Rikimaru, Shigeho; Kakishita, Masao; Kuranishi, Makoto.

    1975-01-01

    In our experience using supervoltage betatron electron beam, the skin surface dose of the electron decreased when the energy became either greater of less than 18 MeV. When we considered 18 MeV to be a 100% dose, the dose with 4 MeV, which was the least amount, corresponded to 81% of the dose. The skin surface dose of 10 MeV betatron electrons or more became greater than the 90% standard tumor dose. An external irradiation of more than 10 MeV should not be applied to neoplasms of which the curative ratio is less than 1.0. Therefore another methods such as intraoperative irradiation, should be used. The surface skin dose about 4-6 MeV betatron postoperative irradiation, particularly after resection of breast cancer, was less than the skin dose with 10 MeV. Close care should be taken to prevent hot lesions which are caused by duplication of irradiation fields. It should be kept in mind that the late effects of hot lesions caused by electron beam irradiation with an energy of 10 MeV or more are serious. (Kashu, E.)

  9. Use of the SPIRAL 2 facility for material irradiations with 14 MeV energy neutrons

    International Nuclear Information System (INIS)

    Mosnier, A.; Ridikas, D.; Ledoux, X.; Pellemoine, F.; Anne, R.; Huguet, Y.; Lipa, M.; Magaud, P.; Marbach, G.; Saint-Laurent, M.G.; Villari, A.C.C.

    2005-01-01

    The primary goal of an irradiation facility for fusion applications will be to generate a material irradiation database for the design, construction, licensing and safe operation of a fusion demonstration power station (e.g., DEMO). This will be achieved through testing and qualifying material performance under neutron irradiation that simulates service up to the full lifetime anticipated in the power plant. Preliminary investigations of 14 MeV neutron effects on different kinds of fusion material could be assessed by the SPIRAL 2 Project at GANIL (Caen, France), aiming at rare isotope beams production for nuclear physics research with first beams expected by 2009. In SPIRAL 2, a deuteron beam of 5 mA and 40 MeV interacts with a rotating carbon disk producing high-energy neutrons (in the range between 1 and 40 MeV) via C (d, xn) reactions. Then, the facility could be used for 3-4 months y -1 for material irradiation purposes. This would correspond to damage rates in the order of 1-2 dpa y -1 (in Fe) in a volume of ∼10 cm 3 . Therefore, the use of miniaturized specimens will be essential in order to effectively utilize the available irradiation volume in SPIRAL 2. Sample package irradiation temperature would be in the range of 250-1000 deg. C. The irradiation level of 1-2 dpa y -1 with 14 MeV neutrons (average energy) may be interesting for micro-structural and metallurgical investigations (e.g., mini-traction, small punch tests, etc.) and possibly for the understanding of specimen size/geometric effects of critical material properties. Due to the small test cell volume, sample in situ experiments are not foreseen. However, sample packages would be, if required, available each month after transfer in a special hot cell on-site

  10. Effects of high-energy (MeV) ion implantation of polyester films

    International Nuclear Information System (INIS)

    Ueno, Keiji; Matsumoto, Yasuyo; Nishimiya, Nobuyuki; Noshiro, Mitsuru; Satou, Mamoru

    1991-01-01

    The effects of high-energy ion beam irradiation on polyester (PET) films using a 3 MeV tandem-type ion beam accelerator were studied. O, Ni, Pt, and Au as ion species were irradiated at 10 14 -10 15 ions/cm 2 on 50 μm thick PET films. Physical properties and molecular structure changes were studied by the surface resistivity measurements and RBS. The surface resistivity decreases with an increase in irradiation dose. At 10 15 ions/cm 2 irradiation, the surface resistivity is 10 8 Ω/□. According to RBS and XPS analyses, some carbon and oxygen atoms in the PET are replaced by implanted ions and the -C=O bonds are destroyed easily by the ion beam. (orig.)

  11. Inductive voltage adder (IVA) for submillimeter radius electron beam

    International Nuclear Information System (INIS)

    Mazarakis, M.G.; Poukey, J.W.; Maenchen, J.E.

    1996-01-01

    The authors have already demonstrated the utility of inductive voltage adder accelerators for production of small-size electron beams. In this approach, the inductive voltage adder drives a magnetically immersed foilless diode to produce high-energy (10--20 MeV), high-brightness pencil electron beams. This concept was first demonstrated with the successful experiments which converted the linear induction accelerator RADLAC II into an IVA fitted with a small 1-cm radius cathode magnetically immersed foilless diode (RADLAC II/SMILE). They present here first validations of extending this idea to mm-scale electron beams using the SABRE and HERMES-III inductive voltage adders as test beds. The SABRE experiments are already completed and have produced 30-kA, 9-MeV electron beams with envelope diameter of 1.5-mm FWHM. The HERMES-III experiments are currently underway

  12. SU-E-T-470: Beam Performance of the Radiance 330 Proton Therapy System

    International Nuclear Information System (INIS)

    Nazaryan, H; Nazaryan, V; Wang, F; Flanz, J; Alexandrov, V

    2014-01-01

    Purpose: The ProTom Radiance 330 proton radiotherapy system is a fully functional, compact proton radiotherapy system that provides advanced proton delivery capabilities. It supports three-dimensional beam scanning with energy and intensity modulation. A series of measurements have been conducted to characterize the beam performance of the first installation of the system at the McLaren Proton Therapy Center in Flint, Michigan. These measurements were part of the technical commissioning of the system. Select measurements and results are presented. Methods: The Radiance 330 proton beam energy range is 70–250 MeV for treatment, and up to 330 MeV for proton tomography and radiography. Its 3-D scanning capability, together with a small beam emittance and momentum spread, provides a highly efficient beam delivery. During the technical commissioning, treatment plans were created to deliver uniform maps at various energies to perform Gamma Index analysis. EBT3 Gafchromic films were irradiated using the Planned irradiation maps. Bragg Peak chamber was used to test the dynamic range during a scan in one layer for high (250 MeV) and Low (70 MeV) energies. The maximum and minimum range, range adjustment and modulation, distal dose falloff (80%–20%), pencil beam spot size, spot placement accuracy were also measured. The accuracy testing included acquiring images, image registration, receiving correction vectors and applying the corrections to the robotic patient positioner. Results: Gamma Index analysis of the Treatment Planning System (TPS) data vs. Measured data showed more than 90% of points within (3%, 3mm) for the maps created by the TPS. At Isocenter Beam Size (One sigma) < 3mm at highest energy (250 MeV) in air. Beam delivery was within 0.6 mm of the intended target at the entrance and the exit of the beam, through the phantom. Conclusion: The Radiance 330 Beam Performance Measurements have confirmed that the system operates as designed with excellent clinical

  13. SU-E-T-470: Beam Performance of the Radiance 330 Proton Therapy System

    Energy Technology Data Exchange (ETDEWEB)

    Nazaryan, H; Nazaryan, V; Wang, F [ProTom International, Inc., Flower Mound, TX (United States); Flanz, J [Massachusetts General Hospital, Boston, MA (United States); Alexandrov, V [ZAO ProTom, Protvino, Moscow region (Russian Federation)

    2014-06-01

    Purpose: The ProTom Radiance 330 proton radiotherapy system is a fully functional, compact proton radiotherapy system that provides advanced proton delivery capabilities. It supports three-dimensional beam scanning with energy and intensity modulation. A series of measurements have been conducted to characterize the beam performance of the first installation of the system at the McLaren Proton Therapy Center in Flint, Michigan. These measurements were part of the technical commissioning of the system. Select measurements and results are presented. Methods: The Radiance 330 proton beam energy range is 70–250 MeV for treatment, and up to 330 MeV for proton tomography and radiography. Its 3-D scanning capability, together with a small beam emittance and momentum spread, provides a highly efficient beam delivery. During the technical commissioning, treatment plans were created to deliver uniform maps at various energies to perform Gamma Index analysis. EBT3 Gafchromic films were irradiated using the Planned irradiation maps. Bragg Peak chamber was used to test the dynamic range during a scan in one layer for high (250 MeV) and Low (70 MeV) energies. The maximum and minimum range, range adjustment and modulation, distal dose falloff (80%–20%), pencil beam spot size, spot placement accuracy were also measured. The accuracy testing included acquiring images, image registration, receiving correction vectors and applying the corrections to the robotic patient positioner. Results: Gamma Index analysis of the Treatment Planning System (TPS) data vs. Measured data showed more than 90% of points within (3%, 3mm) for the maps created by the TPS. At Isocenter Beam Size (One sigma) < 3mm at highest energy (250 MeV) in air. Beam delivery was within 0.6 mm of the intended target at the entrance and the exit of the beam, through the phantom. Conclusion: The Radiance 330 Beam Performance Measurements have confirmed that the system operates as designed with excellent clinical

  14. Polarity-dependence of the defect formation in c-axis oriented ZnO by the irradiation of an 8 MeV proton beam

    Science.gov (United States)

    Koike, Kazuto; Yano, Mitsuaki; Gonda, Shun-ichi; Uedono, Akira; Ishibashi, Shoji; Kojima, Kazunobu; Chichibu, Shigefusa F.

    2018-04-01

    The polarity dependence of the radiation hardness of single-crystalline ZnO bulk crystals is studied by irradiating the Zn-polar and O-polar c-planes with an 8 MeV proton beam up to the fluence of 4.2 × 1016 p/cm2. To analyze the hardness, radiation-induced defects were evaluated using positron annihilation (PA) analysis, and the recovery by post-annealing was examined using continuous-wave photoluminescence (PL) and time-resolved photoluminescence (TRPL) measurements. It was suggested by the PA and PL analyses that the major defects in both polarities were VZnVO divacancies. While the PA data did not show the clear dependence on the polarity, the PL and TRPL results showed that the Zn-polar c-plane had a little higher radiation tolerance than that of the O-polar c-plane, which was consistent with the result that the increase in the electrical resistance by proton beam irradiation was smaller for the former one. Considering these results in total, the polarity dependence is considered to be not so large, but the Zn-polar c-plane has a little higher tolerance than that of the O-polar one.

  15. Analysis of thermionic DC electron gun for 125 MeV linac

    International Nuclear Information System (INIS)

    Kanno, K.; Sato, Isamu; Sato, K.

    2000-01-01

    The beam trace calculation for the 100 kV thermionic DC electron gun with EIMAC 646E cathode, which is currently used for the 125 MeV linac at Nihon University, has been performed using EGUN code. The result showed a strong focus of the beam at the exit of the anode. A better geometry of the gun has been investigated by varying the shape of the wehnelt electrode. Also the trace calculation has been performed for the case of EIMAC 646B, which showed a considerably small emittance compared with that estimated for the present gun. (author)

  16. Analysis of thermionic DC electron gun for 125 MeV linac

    Energy Technology Data Exchange (ETDEWEB)

    Kanno, K. [Graduate School of Science and Technology, Nihon Univ., Funabashi, Chiba (Japan); Sato, Isamu; Sato, K. [Nihon Univ., Funabashi, Chiba (Japan). Atomic Energy Research Inst] [and others

    2000-07-01

    The beam trace calculation for the 100 kV thermionic DC electron gun with EIMAC 646E cathode, which is currently used for the 125 MeV linac at Nihon University, has been performed using EGUN code. The result showed a strong focus of the beam at the exit of the anode. A better geometry of the gun has been investigated by varying the shape of the wehnelt electrode. Also the trace calculation has been performed for the case of EIMAC 646B, which showed a considerably small emittance compared with that estimated for the present gun. (author)

  17. 41 CFR 50-203.20 - Examination of witnesses.

    Science.gov (United States)

    2010-07-01

    ... 41 Public Contracts and Property Management 1 2010-07-01 2010-07-01 true Examination of witnesses... Under the Walsh-Healey Public Contracts Act § 50-203.20 Examination of witnesses. The administrative law... such examination or cross-examination of any witness as may be required for a full and true disclosure...

  18. Children's Witnessing of Adult Domestic Violence.

    Science.gov (United States)

    Edleson, Jeffrey L.

    1999-01-01

    Expands common definitions of how children witness adult domestic violence through a review of 31 research articles. A variety of behavioral, emotional, and cognitive-functioning problems among children were found to be associated with exposure to domestic violence. Factors that appear to moderate the impact of witnessing violence (child abuse,…

  19. 14 CFR 406.161 - Witness fees.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 4 2010-01-01 2010-01-01 false Witness fees. 406.161 Section 406.161 Aeronautics and Space COMMERCIAL SPACE TRANSPORTATION, FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF... the same fees and mileage expenses as are paid to a witness in a court of the United States in...

  20. Status of ACCULINNA beam line

    CERN Document Server

    Rodin, A M; Bogdanov, D D; Golovkov, M S; Fomichev, A S; Sidorchuk, S I; Slepnev, R S; Wolski, R; Ter-Akopian, G M; Oganessian, Yu T; Yukhimchuk, A A; Perevozchikov, V V; Vinogradov, Yu I; Grishenchkin, S K; Demin, A M; Zlatoustovskii, S V; Kuryakin, A V; Filchagin, S V; Ilkaev, R I

    2003-01-01

    The separator ACCULINNA was upgraded to achieve new experimental requirements. The beam line was extended by new ion-optical elements beyond the cyclotron hall. The new arrangements yield much better background conditions. The intensities of sup 6 He and sup 8 He radioactive beams produced in fragmentation of 35 A MeV sup 1 sup 1 B ions were increased up to a factor of 10. The upgraded beam line was used in experiments to study the sup 5 H resonance states populated in the t+t reaction. A cryogenic liquid tritium target was designed and installed at the separator beam line.

  1. Applications of electron lenses: scraping of high-power beams, beam-beam compensation, and nonlinear optics

    Energy Technology Data Exchange (ETDEWEB)

    Stancari, Giulio

    2014-09-11

    Electron lenses are pulsed, magnetically confined electron beams whose current-density profile is shaped to obtain the desired effect on the circulating beam. Electron lenses were used in the Fermilab Tevatron collider for bunch-by-bunch compensation of long-range beam-beam tune shifts, for removal of uncaptured particles in the abort gap, for preliminary experiments on head-on beam-beam compensation, and for the demonstration of halo scraping with hollow electron beams. Electron lenses for beam-beam compensation are being commissioned in the Relativistic Heavy Ion Collider (RHIC) at Brookhaven National Laboratory (BNL). Hollow electron beam collimation and halo control were studied as an option to complement the collimation system for the upgrades of the Large Hadron Collider (LHC) at CERN; a conceptual design was recently completed. Because of their electric charge and the absence of materials close to the proton beam, electron lenses may also provide an alternative to wires for long-range beam-beam compensation in LHC luminosity upgrade scenarios with small crossing angles. At Fermilab, we are planning to install an electron lens in the Integrable Optics Test Accelerator (IOTA, a 40-m ring for 150-MeV electrons) as one of the proof-of-principle implementations of nonlinear integrable optics to achieve large tune spreads and more stable beams without loss of dynamic aperture.

  2. Current neutralization in ballistic transport of light ion beams

    International Nuclear Information System (INIS)

    Hubbard, R.F.; Slinker, S.P.; Lampe, M.; Joyce, G.; Ottinger, P.

    1992-01-01

    Intense light ion beams are being considered as drivers to ignite fusion targets in the Laboratory Microfusion Facility (LMF). Ballistic transport of these beams from the diode to the target is possible only if the beam current is almost completely neutralized by plasma currents. This paper summarizes related work on relativistic electron beam and heavy ion beam propagation and describes a simple simulation model (DYNAPROP) which has been modified to treat light ion beam propagation. DYNAPROP uses an envelope equation to treat beam dynamics and uses rate equations to describe plasma and conductivity generation. The model has been applied both to the high current, 30 MeV Li +3 beams for LMF as well as low current, 1.2 MeV proton beams which are currently being studied on GAMBLE B at the Naval Research Laboratory. The predicted ratio of net currents to beam current is ∼0.1--0.2 for the GAMBLE experiment and ∼0.01 for LMF. The implications of these results for LMF and the GAMBLE experiments art discussed in some detail. The simple resistive model in DYNAPROP has well-known limitations in the 1 torr regime which arise primarily from the neglect of plasma electron transport. Alternative methods for treating the plasma response are discussed

  3. Physics design of a 10 MeV injector test stand for an accelerator-driven subcritical system

    Science.gov (United States)

    Yan, Fang; Pei, Shilun; Geng, Huiping; Meng, Cai; Zhao, Yaliang; Sun, Biao; Cheng, Peng; Yang, Zheng; Ouyang, Huafu; Li, Zhihui; Tang, Jingyu; Wang, Jianli; Sui, Yefeng; Dai, Jianping; Sha, Peng; Ge, Rui

    2015-05-01

    The 10 MeV accelerator-driven subcritical system (ADS) Injector I test stand at Institute of High Energy Physics (IHEP) is a testing facility dedicated to demonstrate one of the two injector design schemes [Injector Scheme-I, which works at 325 MHz], for the ADS project in China. The injector is composed of two parts, the linac part and the beam dump line. The former is designed on the basis of 325 MHz four-vane type copper structure radio frequency quadrupole and superconducting (SC) spoke cavities with β =0.12 . The latter is designed to transport the beam coming out of the SC section of the linac to the beam dump, where the beam transverse profile is fairly enlarged and unformed to simplify the beam target design. The SC section consists of two cryomodules with 14 β =0.12 Spoke cavities, 14 solenoid and 14 BPMs in total. The first challenge in the physics design comes from the necessary space required for the cryomodule separation where the periodical lattice is destroyed at a relatively lower energy of ˜5 MeV . Another challenge is the beam dump line design, as it will be the first beam dump line being built by using a step field magnet for the transverse beam expansion and uniformity in the world. This paper gives an overview of the physics design study together with the design principles and machine construction considerations. The results of an optimized design, fabrication status and end to end simulations including machine errors are presented.

  4. First experience with carbon stripping foils for the 160 MeV H- injection into the CERN PSB

    Science.gov (United States)

    Weterings, Wim; Bracco, Chiara; Jorat, Louise; Noulibos, Remy; van Trappen, Pieter

    2018-05-01

    160 MeV H- beam will be delivered from the new CERN linear accelerator (Linac4) to the Proton Synchrotron Booster (PSB), using a H- charge-exchange injection system. A 200 µg/cm2 carbon stripping foil will convert H- into protons by stripping off the electrons. The H- charge-exchange injection principle will be used for the first time in the CERN accelerator complex and involves many challenges. In order to gain experience with the foil changing mechanism and the very fragile foils, in 2016, prior to the installation in the PSB, a stripping foil test stand has been installed in the Linac4 transfer line. In addition, parts of the future PSB injection equipment are also temporarily installed in the Linac4 transfer line for tests with a 160 MeV H- commissioning proton beam. This paper describes the foil changing mechanism and control system, summarizes the practical experience of gluing and handling these foils and reports on the first results with beam.

  5. High-energy tritium beams as current drivers in tokamak reactors

    International Nuclear Information System (INIS)

    Mikkelsen, D.R.; Grisham, L.R.

    1983-04-01

    The effect on neutral-beam design and reactor performance of using high-energy (approx. 3-10 MeV) tritium neutral beams to drive steady-state tokamak reactors is considered. The lower current of such beams leads to several advantages over lower-energy neutral beams. The major disadvantage is the reduction of the reactor output caused by the lower current-drive efficiency of the high-energy beams

  6. Study of {sup 24}Na activity in concrete using 20-MeV proton beam on Cu

    Energy Technology Data Exchange (ETDEWEB)

    Oranj, Leila Mokhtanri; Jung, Nam Suk; Lee, Arim; Heo, Tae Min; Bakhtian, Mahdi; Lee, Hee Seock [POSTECH, Pohang (Korea, Republic of)

    2017-04-15

    The number of medical cyclotrons capable of accelerating protons to about 20 MeV is increasing in Korea. In such facilities, various radionuclides could be induced in shielding materials like concrete from secondary neutrons which Causes problems from the view point of radiation safety. Among these radionuclides, gamma-ray from {sup 24}Na (Tz1/2 = 15 h) is the most important origin of radiation exposure. {sup 24}Na could be produced from secondary neutrons on Na, Al and Mg component which exist in the concrete. {sup 24} Na Could be produced from thermal neutrons on Na and fast neutron with energy lower than 20 MeV on Al and Mg. Due to interaction of 20 MeV protons on Cu target, secondary neutrons with the energy of less than 20 MeV were produced. therefore, among the concrete components, Na, Al and Mg are only corespondent to produce {sup 24}Na. In this work, {sup 24}Na activity induced in concrete and chemical reagents of concrete (NaHCO{sub 3}, Al{sub 2}O{sub 3} and MgO) were measured. To produce neutrons, Cu target was irradiated by 20 MeV protons. Measured data were compared with results of simulations by FLUKA and MARS as well as earlier works and theocratical data. In the case of Mg and Al chemical reagents, FLUKA code overestimates our measurements by approximately four times, while, for Na sample, FLUKA underestimates the experimental data by almost 0.5. Data from FLUKA and measurement for the concrete are consistent. Calculation from TALYS for Mg overestimates the measured data by a factor of 2.5.

  7. Neutron measurements from beam-target reactions at the ELISE neutral beam test facility

    International Nuclear Information System (INIS)

    Xufei, X.; Fan, T.; Nocente, M.; Gorini, G.; Bonomo, F.; Franzen, P.; Fröschle, M.; Grosso, G.; Tardocchi, M.; Grünauer, F.; Pasqualotto, R.

    2014-01-01

    Measurements of 2.5 MeV neutron emission from beam-target reactions performed at the ELISE neutral beam test facility are presented in this paper. The measurements are used to study the penetration of a deuterium beam in a copper dump, based on the observation of the time evolution of the neutron counting rate from beam-target reactions with a liquid scintillation detector. A calculation based on a local mixing model of deuterium deposition in the target up to a concentration of 20% at saturation is used to evaluate the expected neutron yield for comparison with data. The results are of relevance to understand neutron emission associated to beam penetration in a solid target, with applications to diagnostic systems for the SPIDER and MITICA Neutral Beam Injection prototypes

  8. Study of the neutron-proton interaction in the 300 to 700 MeV energy region. Annual progress report, 1982-1983

    International Nuclear Information System (INIS)

    Northcliffe, L.C.

    1983-01-01

    Progress by the LAMPF user group from Texas A and M University is described. The principal activities since last year's report have included four months of data taking to complete LAMPF Experiment No. 518 (Polarized Beam and Target Experiments in the p-p System. Phase II. Measurements of A/sub zz/ and A/sub xz/ for the d/sub π/ + Channel and for the Elastic Channel from 500 to 800 MeV) which began running in mid-June 1982. There were also about six weeks of data taking on LAMPF Experiment No. 664 (The Measurement of the Polarization Transfer Coefficients A/sub t/' and D/sub t/ at 500, 650 and 800 MeV for the Reaction d(polarized p, polarized n)2p), and one week of data taking at 800 MeV on LAMPF Experiment No. 590 (Measurement of D(theta) in p-n and n-p Scattering at 800, 650 MeV and Other Energies with Associated p-p Measurements). In addition there were preparations for LAMPF Experiment No. 665 (The Measurement of np Elastic Scattering Spin Correlation Parameters with L- and S-Type Polarized Beam and Target between 500 and 800 MeV) which began running last month and will continue until the end of the year

  9. Monte Carlo simulation of small field electron beams for small animal irradiation

    International Nuclear Information System (INIS)

    Lee, Chung-Chi; Chen, Ai-Mei; Tung, Chuan-Jong; Chao, Tsi-Chian

    2011-01-01

    The volume effect of detectors in the dosimetry of small fields for photon beams has been well studied due to interests in radiosurgery and small beamlets used in IMRT treatments; but there is still an unexplored research field for small electron beams used in small animal irradiation. This study proposes to use the BEAM Monte Carlo (MC) simulation to assess characteristics of small electron beams (4, 6, 14, 30 mm in diameter) with the kinetic energies of 6 and 18 MeV. Three factors influencing beam characteristics were studied (1) AE and ECUT settings, (2) photon jaw settings and (3) simulation pixel sizes. Study results reveal that AE/ECUT settings at 0.7 MeV are adequate for linear accelerator treatment head simulation, while 0.521 MeV is more favorable to be used for the phantom study. It is also demonstrated that voxel size setting at 1/4 of the simulation field width in all directions is sufficient to achieve accurate results. As for the photon jaw setting, it has great impact on the absolute output of different field size setting (i.e. output factor) but with minimum effect on the relative lateral distribution.

  10. Radiation protection studies for a high-power 160 MeV proton linac

    CERN Document Server

    Mauro, Egidio

    2009-01-01

    CERN is presently designing a new chain of accelerators to replace the present Proton Synchrotron (PS) complex: a 160 MeV room-temperature H− linac (Linac4) to replace the present 50 MeV proton linac injector, a 3.5 GeV Superconducting Proton Linac (SPL) to replace the 1.4 GeV PS Booster (PSB) and a 50 GeV synchrotron (named PS2) to replace the 26 GeV PS. Linac4 has been funded and the civil engineering work started in October 2008, whilst the SPL is in an advanced stage of design. Beyond injecting into the future 50 GeV PS, the ultimate goal of the SPL is to generate a 4 MW beam for the production of intense neutrino beams. The radiation protection design is driven by the latter requirement. This work summarizes the radiation protection studies conducted for Linac4. FLUKA Monte Carlo simulations, complemented by analytical estimates, were performed to evaluate the propagation of neutrons through the waveguide, ventilation and cable ducts placed along the accelerator, to estimate the radiological impact of ...

  11. Simulation of enhanced characteristic x rays from a 40-MeV electron beam laser accelerated in plasma

    Directory of Open Access Journals (Sweden)

    L. Nikzad

    2012-02-01

    Full Text Available Simulation of x-ray generation from bombardment of various solid targets by quasimonoenergetic electrons is considered. The electron bunches are accelerated in a plasma produced by interaction of 500 mJ, 30 femtosecond laser pulses with a helium gas jet. These relativistic electrons propagate in the ion channel generated in the wake of the laser pulse. A beam of MeV electrons can interact with targets to generate x-ray radiation with keV energy. The MCNP-4C code based on Monte Carlo simulation is employed to compare the production of bremsstrahlung and characteristic x rays between 10 and 100 keV by using two quasi-Maxwellian and quasimonoenergetic energy distributions of electrons. For a specific electron spectrum and a definite sample, the maximum x-ray flux varies with the target thickness. Besides, by increasing the target atomic number, the maximum x-ray flux is increased and shifted towards a higher energy level. It is shown that by using the quasimonoenergetic electron profile, a more intense x ray can be produced relative to the quasi-Maxwellian profile (with the same total energy, representing up to 77% flux enhancement at K_{α} energy.

  12. Injection study of the Radiance 330 synchrotron with a 1.6 MeV RFQ linac

    Science.gov (United States)

    Wang, F.; Flanz, J.; Hamm, R.

    2012-09-01

    The ProTom Radiance 330 proton radiotherapy system provides the most advanced proton delivery capability to date. It supports true three-dimensional beam scanning with dynamic energy and intensity modulation. Most of the protons extracted from the synchrotron are used to treat the patient, which results in minimal neutron background in the treatment room. The patient dose rate depends upon the number of protons injected and the acceleration cycle time. Therefore, one can boost the dose rate by increasing the beam intensity at injection. Improvements to the existing tandem accelerator injector are already underway. However, an alternative way to attain higher intensity beam is to use an RFQ linac as an injector. To this end, a novel 1.6 MeV RFQ linac has been designed to specifically satisfy the small energy acceptance limits of the synchrotron. Simulations of the beam line optics and injection matching to the synchrotron have been performed using the computer codes PARMILA and TRACE-3D to determine if an additional bunching cavity is needed. Assessments of the space charge limit at the relatively low injection energy of 1.6 MeV and RF capture simulations have also been performed. Results of these studies are presented.

  13. Production of light radioactive ion beams (RIB) using inverse kinematics

    International Nuclear Information System (INIS)

    Das, J.J.; Sugathan, P.; Madhavan, N.; Madhusudhana Rao, P.V.; Jhingan, A.; Varughese, T.; Barua, S.; Nath, S.; Sinha, A.K.; Kumar, B.; Zacharias, J.

    2005-01-01

    At Nuclear Science Centre (NSC), New Delhi, we have implemented a facility to produce low energy light radioactive ion beams (RIBs) using (p,n) type of reactions in inverse kinematics. For this purpose primary beams from the 15-UD Pelletron accelerator impinged on a thin polypropylene foil mounted on a rotating/linearly moving target assembly. For efficiently separating the secondary beam from primary beam, the existing recoil mass spectrometer (RMS) HIRA was operated with new ion optics. Suitable hardware modifications were also made. Using this facility, we have extracted a 7 Be beam of purity better than 99% and spot-size ∼4 mm in diameter. This 7 Be beam has been utilized in a variety of experiments in the energy range of 15-22 MeV. Typical beam parameters are: intensity 10 4 pps, angular spread ±30 mrad and energy spread ±0.5 MeV. Development of appropriate detector setup/target arrangement were also made to perform these experiments. In this paper, we describe the implementation of this project

  14. Direct measurement of electron beam quality conversion factors using water calorimetry.

    Science.gov (United States)

    Renaud, James; Sarfehnia, Arman; Marchant, Kristin; McEwen, Malcolm; Ross, Carl; Seuntjens, Jan

    2015-11-01

    In this work, the authors describe an electron sealed water calorimeter (ESWcal) designed to directly measure absorbed dose to water in clinical electron beams and its use to derive electron beam quality conversion factors for two ionization chamber types. A functioning calorimeter prototype was constructed in-house and used to obtain reproducible measurements in clinical accelerator-based 6, 9, 12, 16, and 20 MeV electron beams. Corrections for the radiation field perturbation due to the presence of the glass calorimeter vessel were calculated using Monte Carlo (MC) simulations. The conductive heat transfer due to dose gradients and nonwater materials was also accounted for using a commercial finite element method software package. The relative combined standard uncertainty on the ESWcal dose was estimated to be 0.50% for the 9-20 MeV beams and 1.00% for the 6 MeV beam, demonstrating that the development of a water calorimeter-based standard for electron beams over such a wide range of clinically relevant energies is feasible. The largest contributor to the uncertainty was the positioning (Type A, 0.10%-0.40%) and its influence on the perturbation correction (Type B, 0.10%-0.60%). As a preliminary validation, measurements performed with the ESWcal in a 6 MV photon beam were directly compared to results derived from the National Research Council of Canada (NRC) photon beam standard water calorimeter. These two independent devices were shown to agree well within the 0.43% combined relative uncertainty of the ESWcal for this beam type and quality. Absorbed dose electron beam quality conversion factors were measured using the ESWcal for the Exradin A12 and PTW Roos ionization chambers. The photon-electron conversion factor, kecal, for the A12 was also experimentally determined. Nonstatistically significant differences of up to 0.7% were found when compared to the calculation-based factors listed in the AAPM's TG-51 protocol. General agreement between the relative

  15. Pulsed-neutron production at the Brookhaven 200-MeV linac

    International Nuclear Information System (INIS)

    Ward, T.E.; Alessi, J.; Brennan, J.; Grand, P.; Lankshear, R.; Montemurro, P.; Snead, C.L. Jr.; Tsoupas, N.

    1989-01-01

    The new 750-kV RFQ preinjector and double chopper system capable of selecting single nanosecond micropulses with repetition rates of 0.1 to 20 MHz has been installed at the Brookhaven 200-MeV proton linac. The micropulse intensity is approximately 1 x 10 9 p/μpulse. Neutron time-of-flight path lengths of 30 to 100 meters at 0 degree, 12 degree, 30 degree, 45 degree, 90 degree and 135 degree are available as well as a zero-degree beam swinger capable of an angular range of 0 degree to 25 degree. Pulsed neutron beams of monoenergetic (p 7 Li → n 7 Be) and spallation (p 238 U → nx) sources will be discussed in the present paper as well as detailing the chopped-beam capabilities. 11 refs., 5 figs., 1 tab

  16. High precision electron beam diagnostic system for high current long pulse beams

    International Nuclear Information System (INIS)

    Chen, Y J; Fessenden, T; Holmes, C; Nelson, S D; Selchow, N.

    1999-01-01

    As part of the effort to develop a multi-axis electron beam transport system using stripline kicker technology for DARHT II applications, it is necessary to precisely determine the position and extent of long high energy beams (6-40 MeV, 1-4 kA, 2 microseconds) for accurate position control. The kicker positioning system utilizes shot-to-shot adjustments for reduction of relatively slow (<20 MHz) motion of the beam centroid. The electron beams passing through the diagnostic systems have the potential for large halo effects that tend to corrupt measurements performed using capacitive pick-off probes. Likewise, transmission line traveling wave probes have problems with multi-bounce effects due to these longer pulse widths. Finally, the high energy densities experienced in these applications distort typical foil beam position measurements

  17. A Study on clinical Considerations caused by inevitably Extended SSD for Electron beam therapy

    International Nuclear Information System (INIS)

    Lee, Jung Woo; Kim, Jeong Man

    1996-01-01

    We are often faced with the clinical situations that is inevitably extended SSD for electron beam therapy due to anatomical restriction or applicator structure. But there are some difficulties in accurately predicting output and properties. In electron beam treatment , unlike photon beam the decrease in output for extended SSD does not follow inverse-square law accurately because of a loss of side scatter equilibrium, which is particularly significant for small cone size and low energies. The purpose of our study is to analyze the output in changing with the energy, cone size, air gap beyond the standard SSD and to compare inverse-square law factor derived from calculated effective SSD, mominal SSD with measured output factor. In addition, we have analyzed the change of PDD for several cones with different SSDs which range from 100 cm to 120 cm with 5 cm step and with different energies(6 MeV, 9 MeV, 12 MeV, 16 MeV, 20 MeV). In accordance with our study, an extended SSD produces a significant change in beam output, negligible change in depth dose which range from 100 cm to 120 cm SSDs. In order to deliver the more accurate dose to the neoplastic tissue, first of all we recommend inverse-square law using the table of effective SSDs with cone sizes and energies respectively or simply to create a table of extended SSD air gap correction factor. The second we need to have an insight into some change of dose distribution including PPD, penumbra caused by extended SSD for electron beam therapy.

  18. nGEM fast neutron detectors for beam diagnostics

    International Nuclear Information System (INIS)

    Croci, G.; Claps, G.; Cavenago, M.; Dalla Palma, M.; Grosso, G.; Murtas, F.; Pasqualotto, R.; Perelli Cippo, E.; Pietropaolo, A.; Rebai, M.; Tardocchi, M.; Tollin, M.; Gorini, G.

    2013-01-01

    Fast neutron detectors with a sub-millimetric space resolution are required in order to qualify neutron beams in applications related to magnetically-controlled nuclear fusion plasmas and to spallation sources. A nGEM detector has been developed for the CNESM diagnostic system of the SPIDER NBI prototype for ITER and as beam monitor for fast neutrons lines at spallation sources. The nGEM is a triple GEM gaseous detector equipped with polypropylene and polyethylene layers used to convert fast neutrons into recoil protons through the elastic scattering process. This paper describes the results obtained by testing a nGEM detector at the ISIS spallation source on the VESUVIO beam line. Beam profiles (σ x =14.35 mm, σ y =15.75 mm), nGEM counting efficiency (around 10 -4 for 3 MeV n <15 MeV), detector stability (≈4.5%) and the effect of filtering the beam with different type of materials were successfully measured. The x beam profile was compared to the one measured by a single crystal diamond detector. Finally, the efficiency of the detector was simulated exploiting the GEANT4 tool

  19. College students' behavioral reactions upon witnessing relational peer aggression.

    Science.gov (United States)

    You, Ji-In; Bellmore, Amy

    2014-01-01

    With a sample of 228 college students (82.5% females) from the Midwestern United States, individual factors that contribute to emerging adults' behavioral responses when witnessing relational aggression among their peers were explored. The experience of witnessing relational aggression was found to be systematically associated with college students' behavioral responses to relational aggression through two social cognitive processes: normative beliefs about relational aggression and susceptibility to peer influence. The experience of witnessing relational aggression was associated with defending behavior through normative beliefs about relational aggression and both assisting and reinforcing behavior through normative beliefs about relational aggression and susceptibility to peer influence. The experience of witnessing relational aggression was also associated with onlooking behavior through normative beliefs about relational aggression. The findings indicate that exposure to relational aggression as a witness may influence witness responses because of the way such exposure may shape specific social cognitions. The potential for using the study findings for promoting effective witness interventions among college students is discussed. © 2014 Wiley Periodicals, Inc.

  20. Nuclear and particle physics with inverse compton γ-ray beam

    International Nuclear Information System (INIS)

    Fujiwara, Mamoru

    2004-01-01

    A new facility for GeV γ-ray beams in the energy range of 1.5 - 2.4 GeV is now used to develop hadron physics, and lead to an important finding of ''Penta-quark'' hadron, Θ + particle at 1540 MeV. The experimental results to observe φ and K + mesons guide us to a new look of quark dynamics with strangeness quarks. A beam line for MeV γ-rays is discussed in view of the observation of the parity violation due to the weak-strong coupling in nuclear medium. (author)

  1. 2.5 MeV CW 4-vane RFQ accelerator design for BNCT applications

    Science.gov (United States)

    Zhu, Xiaowen; Wang, Hu; Lu, Yuanrong; Wang, Zhi; Zhu, Kun; Zou, Yubin; Guo, Zhiyu

    2018-03-01

    Boron Neutron Capture Therapy (BNCT) promises a bright future in cancer therapy for its highly selective destruction of cancer cells, using the 10B +n→7Li +4 He reaction. It offers a more satisfactory therapeutic effect than traditional methods for the treatment of malignant brain tumors, head and neck cancer, melanoma, liver cancer and so on. A CW 4-vane RFQ, operating at 162.5 MHz, provides acceleration of a 20 mA proton beam to 2.5 MeV, bombarding a liquid lithium target for neutron production with a soft neutron energy spectrum. The fast neutron yield is about 1.73×1013 n/s. We preliminarily develop and optimize a beam shaping assembly design for the 7Li(p, n)7Be reaction with a 2.5 MeV proton beam. The epithermal neutron flux simulated at the beam port will reach up to 1 . 575 ×109 n/s/cm2. The beam dynamics design, simulation and benchmark for 2.5 MeV BNCT RFQ have been performed with both ParmteqM (V3.05) and Toutatis, with a transmission efficiency higher than 99.6% at 20 mA. To ease the thermal management in the CW RFQ operation, we adopt a modest inter-vane voltage design (U = 65 kV), though this does increase the accelerator length (reaching 5.2 m). Using the well-developed 3D electromagnetic codes, CST MWS and ANSYS HFSS, we are able to deal with the complexity of the BNCT RFQ, taking the contribution of each component in the RF volume into consideration. This allows us to optimize the longitudinal field distribution in a full-length model. Also, the parametric modeling technique is of great benefit to extensive modifications and simulations. In addition, the resonant frequency tuning of this RFQ is studied, giving the tuning sensitivities of vane channel and wall channel as -16.3 kHz/°C and 12.4 kHz/°C, respectively. Finally, both the multipacting level of this RFQ and multipacting suppressing in the coaxial coupler are investigated.

  2. Beam emittance reduction during operation of Indus-2

    Energy Technology Data Exchange (ETDEWEB)

    Fakhri, Ali Akbar, E-mail: fakhri@rrcat.gov.in; Kant, Pradeep; Ghodke, A. D.; Singh, Gurnam [Raja Ramanna Centre for Advanced Technology, Indore 452 013 (India)

    2015-11-15

    Indus-2 storage ring is a 2.5 GeV third generation synchrotron radiation source. This source was commissioned using a moderate optics. Beam injection was accomplished using an off momentum electron beam to avoid difficulties faced in storage of beam at 550 MeV. The injection procedure and relevant beam dynamical studies are discussed. The switch over from the moderate optics to low emittance optics is done at 2.5 GeV after storing the electron beam. The procedure evolved to reduce the beam emittance and its implementation during the operation is discussed.

  3. Intense ion beams for inertial confinement fusion

    International Nuclear Information System (INIS)

    Mehlhorn, T.A.

    1997-01-01

    Intense beams of light of heavy ions are being studied as inertial confinement fusion (ICF) drivers for high yield and energy. Heavy and light ions have common interests in beam transport, targets, and alternative accelerators. Self-pinched transport is being jointly studied. This article reviews the development of intense ion beams for ICF. Light-ion drivers are highlighted because they are compact, modular, efficient and low cost. Issues facing light ions are: (1) decreasing beam divergence; (2) increasing beam brightness; and (3) demonstrating self-pinched transport. Applied-B ion diodes are favored because of efficiency, beam brightness, perceived scalability, achievable focal intensity, and multistage capability. A light-ion concept addressing these issues uses: (1) an injector divergence of ≤ 24 mrad at 9 MeV; (2) two-stage acceleration to reduce divergence to ≤ 12 mrad at 35 MeV; and (3) self-pinched transport accepting divergences up to 12 mrad. Substantial progress in ion-driven target physics and repetitive ion diode technology is also presented. Z-pinch drivers are being pursued as the shortest pulsed power path to target physics experiments and high-yield fusion. However, light ions remain the pulsed power ICF driver of choice for high-yield fusion energy applications that require driver standoff and repetitive operation. 100 refs

  4. Status of the 160 MeV H- Injection into the CERN PSB

    CERN Document Server

    Weterings, W; Benedetto, E; Borburgh, J; Bracco, C; Carli, C; Goddard, B; Hanke, K; Mikulec, B; Newborough, A; Noulibos, R; Tan, J

    2012-01-01

    The 160 MeV H- beam from the LINAC4 will be injected into the 4 superimposed rings of the PS Booster (PSB) with a new H- charge-exchange injection system. This entails a massive upgrade of the injection region. The hardware requirements and constraints, the performance specifications and the design of the H- injection region are described.

  5. Beam loss studies in high-intensity heavy-ion linacs

    International Nuclear Information System (INIS)

    Ostroumov, P.N.; Aseev, V.N.; Lessner, E.S.; Mustapha, B.

    2004-01-01

    A low beam-loss budget is an essential requirement for high-intensity machines and represents one of their major design challenges. In a high-intensity heavy-ion machine, losses are required to be below 1 W/m for hands-on-maintenance. The driver linac of the Rare Isotope Accelerator (RIA) is designed to accelerate beams of any ion to energies from 400 MeV per nucleon for uranium up to 950 MeV for protons with a beam power of up to 400 kW. The high intensity of the heaviest ions is achieved by acceleration of multiple-charge-state beams, which requires a careful beam dynamics optimization to minimize effective emittance growth and beam halo formation. For beam loss simulation purposes, large number of particles must be tracked through the linac. Therefore the computer code TRACK has been parallelized and calculations are being performed on the JAZZ cluster recently inaugurated at ANL. This paper discusses how this powerful tool is being used for simulations for the RIA project to help decide on the high-performance and cost-effective design of the driver linac

  6. A laser-wire beam-energy and beam-profile monitor at the BNL linac

    Energy Technology Data Exchange (ETDEWEB)

    Connolly, R.; Degen, C.; DeSanto, L.; Meng, W.; Michnoff, R.; Minty, M.; Nayak, S.

    2011-03-28

    In 2009 a beam-energy monitor was installed in the high energy beam transport (HEBT) line at the Brookhaven National Lab linac. This device measures the energies of electrons stripped from the 40mA H{sup -} beam by background gas. Electrons are stripped by the 2.0x10{sup -7}torr residual gas at a rate of {approx}1.5x10{sup -8}/cm. Since beam electrons have the same velocities as beam protons, the beam proton energy is deduced by multiplying the electron energy by m{sub p}/m{sub e}=1836. A 183.6MeV H{sup -} beam produces 100keV electrons. In 2010 we installed an optics plates containing a laser and scanning optics to add beam-profile measurement capability via photodetachment. Our 100mJ/pulse, Q-switched laser neutralizes 70% of the beam during its 10ns pulse. This paper describes the upgrades to the detector and gives profile and energy measurements.

  7. Development of beam utilization/application technology

    Energy Technology Data Exchange (ETDEWEB)

    Choi, B H; Kim, Y K; Song, T Y [and others

    1999-05-01

    High power proton accelerator is considered as one of national fundamental research facilities and a key to advanced nuclear technology development, having been widely used in an un detachable relationship with nuclear research in advanced countries. The high power proton accelerator will be installed in several phases as an up front facility of the nuclear waste transmutation system. It is expected that a common understanding and a general agreement over proper utilization of the accelerator should be deduced and that a user program for beam utilization and application should be firmly established in time for the completion of each phase of the accelerator. This high power proton accelerator will consist of several component accelerators and, from up front, accelerators such as injector, RFQ, CCDTL, etc. will be installed in sequence and deliver respectively at each stage beams of 3MeV, 20MeV, 100Mev, etc. to be variously utilized forindustries, defence industry, medical treatment, environmental protection and basic science research. In order for the accelerator to be fully utilized as a national fundamental research facility beyond nuclear field, it is necessary to formulate a proceeding plan of the user program for the accelerator and to cultivate industrial utilization/application studies of proton beams accelerated by injector or RFQ of the accelerator. (author). 38 refs., 84 tabs., 39 figs.

  8. Development of beam utilization/application technology

    International Nuclear Information System (INIS)

    Choi, B. H.; Kim, Y.K.; Song, T.Y.

    1999-05-01

    High power proton accelerator is considered as one of national fundamental research facilities and a key to advanced nuclear technology development, having been widely used in an un detachable relationship with nuclear research in advanced countries. The high power proton accelerator will be installed in several phases as an up front facility of the nuclear waste transmutation system. It is expected that a common understanding and a general agreement over proper utilization of the accelerator should be deduced and that a user program for beam utilization and application should be firmly established in time for the completion of each phase of the accelerator. This high power proton accelerator will consist of several component accelerators and, from up front, accelerators such as injector, RFQ, CCDTL, etc. will be installed in sequence and deliver respectively at each stage beams of 3MeV, 20MeV, 100Mev, etc. to be variously utilized for industries, defence industry, medical treatment, environmental protection and basic science research. In order for the accelerator to be fully utilized as a national fundamental research facility beyond nuclear field, it is necessary to formulate a proceeding plan of the user program for the accelerator and to cultivate industrial utilization/application studies of proton beams accelerated by injector or RFQ of the accelerator. (author). 38 refs., 84 tabs., 39 figs

  9. Transition radiation electron beam diagnostic study at ATF

    International Nuclear Information System (INIS)

    Qiu, X.Z.; Wang, X.J.; Batchelor, K.; Ben-Zvi, I.

    1995-01-01

    Recently we have started a program to develop transition radiation based electron beam diagnostics at the Accelerator Test Facility at Brookhaven National Laboratory. In this paper, we will discuss a technique to estimate the lower limit in electron beam divergence measurement with single foil transition radiation and two-foil transition radiation interferometer. Preliminary experimental data from 4.5 MeV electron beam will be presented

  10. In-beam PET at high-energy photon beams: a feasibility study

    Science.gov (United States)

    Müller, H.; Enghardt, W.

    2006-04-01

    For radiation therapy with carbon ion beams, either for the stable isotope 12C or for the radioactive one 11C, it has been demonstrated that the β+-activity distribution created or deposited, respectively, within the irradiated volume can be visualized by means of positron emission tomography (PET). The PET images provide valuable information for quality assurance and precision improvement of ion therapy. Dedicated PET scanners have been integrated into treatment sites at the Heavy Ion Medical Accelerator at Chiba (HIMAC), Japan, and the Gesellschaft für Schwerionenforschung (GSI), Germany, to make PET imaging feasible during therapeutic irradiation (in-beam PET). A similar technique may be worthwhile for radiotherapy with high-energy bremsstrahlung. In addition to monitoring the dose delivery process which in-beam PET has been primarily developed for, it may be expected that radiation response of tissue can be detected by means of in-beam PET. We investigate the applicability of PET for treatment control in the case of using bremsstrahlung spectra produced by 15-50 MeV electrons. Target volume activation due to (γ, n) reactions at energies above 20 MeV yields moderate β+-activity levels, which can be employed for imaging. The radiation from positrons produced by pair production is not presently usable because the detectors are overloaded due to the low duty factor of medical electron linear accelerators. However, the degradation of images caused by positron motion between creation and annihilation seems to be tolerable.

  11. AECL IMPELA electron beam industrial irradiators

    International Nuclear Information System (INIS)

    Labrie, J.P.; Drewell, N.H.; Ebrahim, N.A.; Lawrence, C.B.; Mason, V.A.; Ungrin, J.; White, B.F.

    1989-01-01

    A family of industrial irradiators is being developed by AECL to cover an electron-beam energy range from 5 to 18 MeV at beam powers between 20 and 250 kW. The IMPELA family of irradiators is designed for push button, reliable operation. The major irradiator components are modular, allowing for later upgrades to meet increased demands in either electron or X-ray mode. Interface between the control system, irradiator availability and dose quality assurance is in conformance with the most demanding specifications. The IMPELA irradiators use a klystron-driven, standing-wave, L-band accelerator structure with direct injection from a rugged, triode electron gun. Direct control of the accelerating field during the beam pulse ensures constant output beam energy, independent of beam power. The first member of the family, the IMPELA 10/50 (10 MeV, 50 kW), is in the final stages of assembly at Chalk River Nuclear Laboratories. The IMPELA 10/50 is constructed around a 3.25 m long, high-power-capacity accelerator structure operated at a duty factor of 5%. Beam loading exceeds 60%. The rf power is provided by a 2 MW/150 kW modulated-anode klystron protected from load mismatches by a circulator. This prototype will be used to demonstrate the reliability and dose uniformity targets of the IMPELA family. Full beam operation of the IMPELA 10/50 is scheduled for early 1989. (orig.)

  12. Expert witness and Jungian archetypes.

    Science.gov (United States)

    Lallave, Juan Antonio; Gutheil, Thomas Gordon

    2012-01-01

    Jung's theories of archetype, shadow, and the personal and collective unconscious provide a postmodern framework in which to consider the role of the expert witness in judicial proceedings. Archetypal themes, motifs, and influences help to illuminate the shadow of the judicial system and projections and behaviors among the cast of the court in pursuing justice. This article speaks to archetypal influences and dialectical tensions encountered by the expert witness in this judicial drama. The archetype of Justice is born from the human need for order and relational fairness in a world of chaos. The persona of justice is the promise of truth in the drama. The shadow of justice is untruth, the need to win by any means. The dynamics of the trickster archetype serve and promote injustice. These influences are examined by means of a case example. This approach will deepen understanding of court proceedings and the role of the expert witness in the heroic quest for justice. Copyright © 2012 Elsevier Ltd. All rights reserved.

  13. Measurement of characteristic prompt gamma rays emitted from oxygen and carbon in tissue-equivalent samples during proton beam irradiation.

    Science.gov (United States)

    Polf, Jerimy C; Panthi, Rajesh; Mackin, Dennis S; McCleskey, Matt; Saastamoinen, Antti; Roeder, Brian T; Beddar, Sam

    2013-09-07

    The purpose of this work was to characterize how prompt gamma (PG) emission from tissue changes as a function of carbon and oxygen concentration, and to assess the feasibility of determining elemental concentration in tissues irradiated with proton beams. For this study, four tissue-equivalent water-sucrose samples with differing densities and concentrations of carbon, hydrogen, and oxygen were irradiated with a 48 MeV proton pencil beam. The PG spectrum emitted from each sample was measured using a high-purity germanium detector, and the absolute detection efficiency of the detector, average beam current, and delivered dose distribution were also measured. Changes to the total PG emission from (12)C (4.44 MeV) and (16)O (6.13 MeV) per incident proton and per Gray of absorbed dose were characterized as a function of carbon and oxygen concentration in the sample. The intensity of the 4.44 MeV PG emission per incident proton was found to be nearly constant for all samples regardless of their carbon concentration. However, we found that the 6.13 MeV PG emission increased linearly with the total amount (in grams) of oxygen irradiated in the sample. From the measured PG data, we determined that 1.64 × 10(7) oxygen PGs were emitted per gram of oxygen irradiated per Gray of absorbed dose delivered with a 48 MeV proton beam. These results indicate that the 6.13 MeV PG emission from (16)O is proportional to the concentration of oxygen in tissue irradiated with proton beams, showing that it is possible to determine the concentration of oxygen within tissues irradiated with proton beams by measuring (16)O PG emission.

  14. Current density monitor for intense relativistic electron beams

    International Nuclear Information System (INIS)

    Fiorito, R.B.; Raleigh, M.; Seltzer, S.M.

    1986-01-01

    We describe a new type of electric probe which is capable of measuring the time-resolved current density profile of a stable, reproducible, high-energy (>4-MeV) high-current (>1-kA) electron beam. The sensing element of this probe is an open-ended but capped-off 50-Ω coaxial line constructed of graphite. The graphite sensor is 4.3 mm in diameter, 6 cm long, and is range thin to the primary beam electrons. The probe produces a signal proportional to the intercepted beam current. When the sensor is scanned radially through the beam during repeated pulses, a curve of signal versus depth of insertion is produced from which the radial current density profile can be determined. Measurements are presented of the profile of the electron beam from the Experimental Test Accelerator (4.5 MeV, 10 kA) at Lawrence Livermore National Laboratory. Good agreement is shown between measurements made with this probe and the beam radius as predicted by transport codes. The advantage of the electric probe lies in its ruggedness, simplicity, inherent fast rise time, and low cost. In contrast to other systems it requires no radiation shielding, water cooling, or auxiliary support equipment to operate in an intense beam environment

  15. Properties of the TRIUMF cyclotron beam

    International Nuclear Information System (INIS)

    Craddock, M.K.; Blackmore, E.W.; Dutto, G.; Kost, C.J.; Mackenzie, G.H.; Richardson, J.R.; Root, L.W.; Schmor, P.

    1975-08-01

    Eight percent of the 300 keV d.c. beam from the ion source can be transmitted to 500 MeV in the TRIUMF cyclotron, without using the buncher. The beam losses are entirely accounted for; there are no significant losses due to orbit dynamic problems during 1500 turns of acceleration. The phase history is in good agreement with predictions based on the magnetic field survey. The effect of the harmonic coils and injection parameters on beam quality has been investigated. (author)

  16. Polypropylene compositional evolution under 3.5 MeV He{sup +} ion irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Abdesselam, M., E-mail: abdesselam_m@yahoo.fr [Faculte de Physique, USTHB, BP32, El Alia, 16111 BEZ (Algeria); Muller, D. [InESS, UMR7163, 23 rue du Loess, BP20, F-67037 Strasbourg Cedex 02 (France); Djebara, M.; Chami, A.C. [Faculte de Physique, USTHB, BP32, El Alia, 16111 BEZ (Algeria); Montgomery, P. [InESS, UMR7163, 23 rue du Loess, BP20, F-67037 Strasbourg Cedex 02 (France)

    2012-05-01

    A helium beam at 3.5 MeV was used to induce damage in thin polypropylene film of 5.1 {mu}m in thickness. The fluence ranges from 2 Multiplication-Sign 10{sup 12} to 3.5 Multiplication-Sign 10{sup 15} cm{sup -2}. The evolution of the atomic composition (C and H) as a function of the fluence was investigated in situ by forward elastic scattering (C({alpha}, {alpha})C) and hydrogen elastic recoil detection (H({alpha}, H){alpha}), respectively. The helium beam was used at the same time for irradiation and analysis. In respect to the high sensitivity of the polypropylene to radiation damage, the beam current was kept at very low intensity of 0.5 nA. The mass loss becomes significant above a fluence of {approx}5 Multiplication-Sign 10{sup 13} He{sup +} cm{sup -2}. The carbon depletion levels off at a fluence of {approx}5 Multiplication-Sign 10{sup 14} He{sup +} cm{sup -2} approximately while hydrogen loss continues to be present along the whole of the studied fluence range. The final carbon and hydrogen losses, at the highest fluence, are around 17% and 48% of their initial contents, respectively. Satisfactory fits to the release curves have been obtained in the framework of the bulk molecular recombination model (BMR). The deduced hydrogen and carbon release cross sections are 7.8 and 65.2 Multiplication-Sign 10{sup -16} cm{sup 2}, respectively. A comparison with our previous measurements of polyethylene terephthalate (PET) film irradiated with 3.7 MeV He{sup +} beam is made.

  17. The tagged photon beam facility at the Bonn 500 MeV synchrotron

    International Nuclear Information System (INIS)

    Arends, J.; Eyink, J.; Hartmann, H.; Hegerath, A.; Mecking, B.; Ros, H.

    1982-01-01

    A facility for the investigation of medium energy photonuclear reactions is described. A bremsstrahlung tagging system produces a precisely known flux of monochromatic photons in the energy range between 100 and 450 MeV. Resolution and intensity of the system are given. Photoemitted particles can be detected in various large solid angle detectors. The performance of the facility and future developments are discussed. (orig.)

  18. Ultrafast laser driven micro-lens to focus and energy select MeV protons

    International Nuclear Information System (INIS)

    Toncian, Toma

    2008-05-01

    A technique for simultaneous focusing and energy selection of high-current, MeV proton beams using radial, transient electric fields (10 7 -10 10 V/m) triggered on the inner wall of a hollow micro-cylinder by an intense, sub-picosecond laser-pulse is presented. Due to the transient nature of the radial focusing field, the proposed method allows selection of a desired range out of the spectrum of the poly-energetic proton beam. This technique addresses current drawbacks of laser-accelerated proton beams, i.e. their broad spectrum and divergence at the source. This thesis presents both experimental and computational studies that led to the understanding of the physical processes driving the micro-lens. After an one side irradiation of a hollow metallic cylinder a radial electric field develops inside the cylinder. Hot electrons generated by the interaction between laser pulse and cylinder wall spread inside the cylinder generating a plasma at the wall. This plasma expands into vacuum and sustains an electric field that acts as a collecting lens on a proton beam propagating axially through the cylinder. Both focusing and the reduction of the intrinsic beam divergence from 20 deg to.3 deg for a narrow spectral range was demonstrated. By sub-aperturing the beam a narrow spectral range (δε/ε < 3%) was selected from the poly-energetic beam. The micro-lens properties are tunable allowing for optimization towards applications. Optical probing techniques and proton imaging were employed to study the spacial and temporal evolution of the field and revealed a complex physical scenario of the rise and decay of the radial electric field. Each aspect studied experimentally is interpreted using 2D PIC and ray tracing simulations. A very good agreement between the experimental and computational data is found. The PIC simulations are used to upscale the demonstrated micro-lens capabilities to the focusing of a 270 MeV proton beam, an energy relevant for medical applications such

  19. Ultrafast laser driven micro-lens to focus and energy select MeV protons

    Energy Technology Data Exchange (ETDEWEB)

    Toncian, Toma

    2008-05-15

    A technique for simultaneous focusing and energy selection of high-current, MeV proton beams using radial, transient electric fields (10{sup 7}-10{sup 10} V/m) triggered on the inner wall of a hollow micro-cylinder by an intense, sub-picosecond laser-pulse is presented. Due to the transient nature of the radial focusing field, the proposed method allows selection of a desired range out of the spectrum of the poly-energetic proton beam. This technique addresses current drawbacks of laser-accelerated proton beams, i.e. their broad spectrum and divergence at the source. This thesis presents both experimental and computational studies that led to the understanding of the physical processes driving the micro-lens. After an one side irradiation of a hollow metallic cylinder a radial electric field develops inside the cylinder. Hot electrons generated by the interaction between laser pulse and cylinder wall spread inside the cylinder generating a plasma at the wall. This plasma expands into vacuum and sustains an electric field that acts as a collecting lens on a proton beam propagating axially through the cylinder. Both focusing and the reduction of the intrinsic beam divergence from 20 deg to.3 deg for a narrow spectral range was demonstrated. By sub-aperturing the beam a narrow spectral range ({delta}{epsilon}/{epsilon} < 3%) was selected from the poly-energetic beam. The micro-lens properties are tunable allowing for optimization towards applications. Optical probing techniques and proton imaging were employed to study the spacial and temporal evolution of the field and revealed a complex physical scenario of the rise and decay of the radial electric field. Each aspect studied experimentally is interpreted using 2D PIC and ray tracing simulations. A very good agreement between the experimental and computational data is found. The PIC simulations are used to upscale the demonstrated micro-lens capabilities to the focusing of a 270 MeV proton beam, an energy relevant

  20. Photoneutron source based on a compact 10 MeV betatron

    International Nuclear Information System (INIS)

    Chakhlov, V.L.; Bell, Z.W.; Golovkov, V.M.; Shtein, M.M.

    1999-01-01

    Accelerator-based photoneutron sources have enjoyed wide use and offer the advantages of long term stability, ease of control and absence of radioactive materials. We report here measurements of the yield of photoneutrons from a neutron generator using a compact betatron. Electrons were accelerated to energies up to 10 MeV and produced a bremsstrahlung beam with a dose rate of 0.16 Gy/min (at 10 MeV, 1 m from the bremsstrahlung target) to irradiate LiD, Be, depleted U, and Pb neutron-producing targets. The angular distributions of photoneutrons produced by bremsstrahlung beams were measured with a 'long' counter and integrated to determine neutron yield. In addition, neutron time of flight spectra were recorded from all targets using a 15.5 m flight path perpendicular to the photon beam. The maximum observed yields were 4.6x10 7 n/s obtained with 1 kg of LiD, 5.7x10 7 n/s from a 3.3 kg Be block, 6.2x10 6 n/s from 1.5 kg of depleted U, and 7.0x10 6 n/s from 10.7 kg of Pb. Optimization of target dimensions, shape, and positioning is expected to increase the yield from the LiD target by a factor of 35, while optimization of the other targets is expected to yield at most a factor of 10. With the increased yield and a deuteride target, this compact betatron-based system could find application in the interrogation of waste containers for fissile material

  1. Characterization of an add-on multileaf collimator for electron beam therapy

    Energy Technology Data Exchange (ETDEWEB)

    Gauer, T; Sokoll, J; Cremers, F; Schmidt, R [Department of Radiotherapy and Radio-Oncology, University Medical Center Hamburg-Eppendorf, Hamburg (Germany); Harmansa, R [3D Line, Schwarzenbruck (Germany); Luzzara, M [3D Line, Milan (Italy)], E-mail: t.gauer@uke.uni-hamburg.de

    2008-02-21

    An add-on multileaf collimator for electrons (eMLC) has been developed that provides computer-controlled beam collimation and isocentric dose delivery. The design parameters result from the design study by Gauer et al (2006 Phys. Med. Biol. 51 5987-6003) and were configured such that a compact and light-weight eMLC with motorized leaves can be industrially manufactured and stably mounted on a conventional linear accelerator. In the present study, the efficiency of an initial computer-controlled prototype was examined according to the design goals and the performance of energy- and intensity-modulated treatment techniques. This study concentrates on the attachment and gantry stability as well as the dosimetric characteristics of central-axis and off-axis dose, field size dependence, collimator scatter, field abutment, radiation leakage and the setting of the accelerator jaws. To provide isocentric irradiation, the eMLC can be placed either 16 or 28 cm above the isocentre through interchangeable holders. The mechanical implementation of this feature results in a maximum field displacement of less than 0.6 mm at 90{sup 0} and 270{sup 0} gantry angles. Compared to a 10 x 10 cm applicator at 6-14 MeV, the beam penumbra of the eMLC at a 16 cm collimator-to-isocentre distance is 0.8-0.4 cm greater and the depth-dose curves show a larger build-up effect. Due to the loss in energy dependence of the therapeutic range and the much lower dose output at small beam sizes, a minimum beam size of 3 x 3 cm is necessary to avoid suboptimal dose delivery. Dose output and beam symmetry are not affected by collimator scatter when the central axis is blocked. As a consequence of the broader beam penumbra, uniform dose distributions were measured in the junction region of adjacent beams at perpendicular and oblique beam incidence. However, adjacent beams with a high difference in a beam energy of 6 to 14 MeV generate cold and hot spots of approximately 15% in the abutting region. In

  2. Characterization of an add-on multileaf collimator for electron beam therapy

    International Nuclear Information System (INIS)

    Gauer, T; Sokoll, J; Cremers, F; Schmidt, R; Harmansa, R; Luzzara, M

    2008-01-01

    An add-on multileaf collimator for electrons (eMLC) has been developed that provides computer-controlled beam collimation and isocentric dose delivery. The design parameters result from the design study by Gauer et al (2006 Phys. Med. Biol. 51 5987-6003) and were configured such that a compact and light-weight eMLC with motorized leaves can be industrially manufactured and stably mounted on a conventional linear accelerator. In the present study, the efficiency of an initial computer-controlled prototype was examined according to the design goals and the performance of energy- and intensity-modulated treatment techniques. This study concentrates on the attachment and gantry stability as well as the dosimetric characteristics of central-axis and off-axis dose, field size dependence, collimator scatter, field abutment, radiation leakage and the setting of the accelerator jaws. To provide isocentric irradiation, the eMLC can be placed either 16 or 28 cm above the isocentre through interchangeable holders. The mechanical implementation of this feature results in a maximum field displacement of less than 0.6 mm at 90 0 and 270 0 gantry angles. Compared to a 10 x 10 cm applicator at 6-14 MeV, the beam penumbra of the eMLC at a 16 cm collimator-to-isocentre distance is 0.8-0.4 cm greater and the depth-dose curves show a larger build-up effect. Due to the loss in energy dependence of the therapeutic range and the much lower dose output at small beam sizes, a minimum beam size of 3 x 3 cm is necessary to avoid suboptimal dose delivery. Dose output and beam symmetry are not affected by collimator scatter when the central axis is blocked. As a consequence of the broader beam penumbra, uniform dose distributions were measured in the junction region of adjacent beams at perpendicular and oblique beam incidence. However, adjacent beams with a high difference in a beam energy of 6 to 14 MeV generate cold and hot spots of approximately 15% in the abutting region. In order to

  3. The use of electron beams for pasteurization of meats

    International Nuclear Information System (INIS)

    Prestwich, K.R.; Kaye, R.J.; Turman, B.N.; Neau, E.L.

    1994-01-01

    Electron beam accelerators can be used for electronic pasteurization of meat products by: (1) using the electrons directly impacting the products, or (2) optimizing the conversion of electron energy to x-rays and treating the product with these x-rays. The choice of process depends on the configuration of the product when it is treated. For electron treatment, ten million electron volt (MeV) kinetic energy is the maximum allowed by international agreement. The depth of penetration of electrons with that energy into a product with density of meat is about five centimeters (cm). Two-sided treatment can be done on products up to 10 cm thick with a two-to-one ratio between minimum and maximum dose. Ground beef patties are about 1.25 cm (0.5 inch thick). Beams with 2.5 MeV electron energy could be used to treat these products. Our calculations show that maximum to minimum dose ratios less than 1.2 can be achieved with this energy if the transverse beam energy is small. If the product thickness is greater than 10 cm, x-rays can provide the needed dose uniformity. Uniform doses can be supplied for pallets with dimensions greater than 1.2 m on each side using x-rays from a 5 MeV electron beam. The efficiency of converting the electron beam to x-rays and configurations to achieve dose uniformity are discussed

  4. Reacceleration experiment to demonstrate the concept of efficiency enhancement in a relativistic klystron two-beam accelerator

    International Nuclear Information System (INIS)

    Westenskow, G.A.; Houck, T.L.

    1993-05-01

    High conversion efficiency of electro beam energy to rf energy can be achieved in two-beam accelerators using reacceleration of the bunched drive beam. To study issues with these designs we are planning a demonstration in which a modulated beam's energy is boosted as it passes through induction accelerator cells. For this experiment we will use the front end of the Choppertron to modulate a 5 MeV electron beam at 11.4 GHz. We have now tested the 5-MeV Choppertron and are reporting on the results. For the reacceleration experiment we plan to use three stages of rf power extraction interspersed with two stages of reacceleration

  5. Charge-state distributions of 100, 175, 275, and 352 MeV gold ions emerging from thin carbon foils

    International Nuclear Information System (INIS)

    Martin, J.A.; Auble, R.L.; Erb, K.A.; Jones, C.M.; Olsen, D.K.

    1985-01-01

    These measurements were undertaken as a consequence of our failure early this year to accelerate Au +46 ions in the Oak Ridge Isochronous Cyclotron using an injected beam of 352 MeV 197 Au +17 from the 25 MV tandem accelerator. Following that unsuccessful test, we made a preliminary measurement of the charge-state distribution of 352 MeV 197 Au ions emerging from a carbon foil using the bending magnet that is a part of the cyclotron beam injection system. The measured mean charge was approx.38.5, about 4.5 charge-states lower than predicted by the Sayer semi-empirical formula. The measurements reported here were done more precisely and systematically confirm that preliminary result. 12 refs., 5 figs., 4 tabs

  6. Charge-state distributions of 100, 175, 275, and 352 MeV gold ions emerging from thin carbon foils

    Energy Technology Data Exchange (ETDEWEB)

    Martin, J.A.; Auble, R.L.; Erb, K.A.; Jones, C.M.; Olsen, D.K.

    1985-01-01

    These measurements were undertaken as a consequence of our failure early this year to accelerate Au/sup +46/ ions in the Oak Ridge Isochronous Cyclotron using an injected beam of 352 MeV /sup 197/Au/sup +17/ from the 25 MV tandem accelerator. Following that unsuccessful test, we made a preliminary measurement of the charge-state distribution of 352 MeV /sup 197/Au ions emerging from a carbon foil using the bending magnet that is a part of the cyclotron beam injection system. The measured mean charge was approx.38.5, about 4.5 charge-states lower than predicted by the Sayer semi-empirical formula. The measurements reported here were done more precisely and systematically confirm that preliminary result. 12 refs., 5 figs., 4 tabs.

  7. Charged-particle beam diagnostics for the Advanced Photon Source (APS)

    International Nuclear Information System (INIS)

    Lumpkin, A.H.; Decker, G.; Kahana, E.; Patterson, D.; Sellyey, W.; Wang, X.; Chung, Y.

    1992-01-01

    Plans, prototypes, and initial test results for the charged-particle beam (e - , e + ) diagnostic systems on the injector rings, their transport lines, and the storage ring for the Advanced Photon Source (APS) are presented. The APS will be a synchrotron radiation user facility with one of the world's brightest x-ray sources in the 10-keV to 100-keV regime. Its 200-MeV electron linac, 450-MeV positron linac, positron accumulator ring, 7-GeV booster synchrotron, 7-GeV storage ring, and undulator test lines will also demand the development and demonstration of key particle-beam characterization techniques over a wide range of parameter space. Some of these parameter values overlap or approach those projected for fourth generation light sources (linac-driven FELs and high brightness storage rings) as described at a recent workshop. Initial results from the diagnostics prototypes on the linac test stand operating at 45-MeV include current monitor data, beam loss monitor data, and video digitization using VME architecture

  8. Gafchromic EBT3 film dosimetry in electron beams — energy dependence and improved film read‐out

    Science.gov (United States)

    Ojala, Jarkko; Kaijaluoto, Sampsa; Jokelainen, Ilkka; Kosunen, Antti

    2016-01-01

    For megavoltage photon radiation, the fundamental dosimetry characteristics of Gafchromic EBT3 film were determined in  60Co gamma ray beam with addition of experimental and Monte Carlo (MC)‐simulated energy dependence of the film for 6 MV photon beam and 6 MeV, 9 MeV, 12 MeV, and 16 MeV electron beams in water phantom. For the film read‐out, two phase correction of scanner sensitivity was applied: a matrix correction for scanning area and dose‐dependent correction by iterative procedure. With these corrections, the uniformity of response can be improved to be within ±50 pixel values (PVs). To improve the read‐out accuracy, a procedure with flipped film orientations was established. With the method, scanner uniformity can be improved further and dust particles, scratches and/or dirt on scanner glass can be detected and eliminated. Responses from red and green channels were averaged for read‐out, which decreased the effect of noise present in values from separate channels. Since the signal level with the blue channel is considerably lower than with other channels, the signal variation due to different perturbation effects increases the noise level so that the blue channel is not recommended to be used for dose determination. However, the blue channel can be used for the detection of emulsion thickness variations for film quality evaluations with unexposed films. With electron beams ranging from 6 MeV to 16 MeV and at reference measurement conditions in water, the energy dependence of the EBT3 film is uniform within 0.5%, with uncertainties close to 1.6% (k=2). Including 6 MV photon beam and the electron beams mentioned, the energy dependence is within 1.1%. No notable differences were found between the experimental and MC‐simulated responses, indicating negligible change in intrinsic energy dependence of the EBT3 film for 6 MV photon beam and 6 MeV–16 MeV electron beams. Based on the dosimetric characteristics of the EBT3 film, the read

  9. Effects of physics change in Monte Carlo code on electron pencil beam dose distributions

    International Nuclear Information System (INIS)

    Toutaoui, Abdelkader; Khelassi-Toutaoui, Nadia; Brahimi, Zakia; Chami, Ahmed Chafik

    2012-01-01

    Pencil beam algorithms used in computerized electron beam dose planning are usually described using the small angle multiple scattering theory. Alternatively, the pencil beams can be generated by Monte Carlo simulation of electron transport. In a previous work, the 4th version of the Electron Gamma Shower (EGS) Monte Carlo code was used to obtain dose distributions from monoenergetic electron pencil beam, with incident energy between 1 MeV and 50 MeV, interacting at the surface of a large cylindrical homogeneous water phantom. In 2000, a new version of this Monte Carlo code has been made available by the National Research Council of Canada (NRC), which includes various improvements in its electron-transport algorithms. In the present work, we were interested to see if the new physics in this version produces pencil beam dose distributions very different from those calculated with oldest one. The purpose of this study is to quantify as well as to understand these differences. We have compared a series of pencil beam dose distributions scored in cylindrical geometry, for electron energies between 1 MeV and 50 MeV calculated with two versions of the Electron Gamma Shower Monte Carlo Code. Data calculated and compared include isodose distributions, radial dose distributions and fractions of energy deposition. Our results for radial dose distributions show agreement within 10% between doses calculated by the two codes for voxels closer to the pencil beam central axis, while the differences are up to 30% for longer distances. For fractions of energy deposition, the results of the EGS4 are in good agreement (within 2%) with those calculated by EGSnrc at shallow depths for all energies, whereas a slightly worse agreement (15%) is observed at deeper distances. These differences may be mainly attributed to the different multiple scattering for electron transport adopted in these two codes and the inclusion of spin effect, which produces an increase of the effective range of

  10. Witness memory and alcohol: The effects of state-dependent recall.

    Science.gov (United States)

    Schreiber Compo, Nadja; Carol, Rolando N; Evans, Jacqueline R; Pimentel, Pamela; Holness, Howard; Nichols-Lopez, Kristin; Rose, Stefan; Furton, Kenneth G

    2017-04-01

    Many real-world eyewitnesses are under the influence of alcohol either at the time of the crime, the interview, or both. Only recently has empirical research begun to examine the effects of alcohol on witness memory, yielding mixed results. The present study tested the importance of state-dependent memory in the context of alcohol's effects on encoding versus retrieval of a witnessed event, while simultaneously informing real-world investigative practices: Should witnesses sober up before an interview? Participants (N = 249) were randomized to a control, placebo, or alcohol condition at encoding and to either an immediate retrieval condition (in the same state) or a 1-week delay control, placebo, or alcohol retrieval condition. They recalled a witnessed mock crime using open ended and cued recall formats. After a delay, witnesses intoxicated at both encoding and retrieval provided less accurate information than witnesses in sober or placebo groups at both times. There was no advantage of state-dependent memory but intoxicated witnesses were best when recalling immediately compared to 1 week later (sober, placebo, or reintoxicated). Findings have direct implications for the timing of intoxicated witnesses' interviews such that moderately intoxicated witnesses may not benefit from a sobering delay but rather, should be interviewed immediately. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  11. The beam diagnostic instruments in Beijing radioactive ion-beam facilities isotope separator on-line

    International Nuclear Information System (INIS)

    Ma, Y.; Cui, B.; Ma, R.; Tang, B.; Chen, L.; Huang, Q.; Jiang, W.

    2014-01-01

    The beam diagnostic instruments for Beijing Radioactive Ion-beam Facilities Isotope Separator On-Line are introduced [B. Q. Cui, Z. H. Peng, Y. J. Ma, R. G. Ma, B. Tang, T. Zhang, and W. S. Jiang, Nucl. Instrum. Methods 266, 4113 (2008); T. J. Zhang, X. L. Guan, and B. Q. Cui, in Proceedings of APAC 2004, Gyeongju, Korea, 2004, http://www.jacow.org , p. 267]. For low intensity ion beam [30–300 keV/1 pA–10 μA], the beam profile monitor, the emittance measurement unit, and the analyzing slit will be installed. For the primary proton beam [100 MeV/200 μA], the beam profile scanner will be installed. For identification of the nuclide, a beam identification unit will be installed. The details of prototype of the beam diagnostic units and some experiment results will be described in this article

  12. Off-line production of a sup 7 Be radioactive ion beam

    CERN Document Server

    Gialanella, L; De Cesare, N; D'Onofrio, A; Romano, M; Campajola, L; Formicola, A; Fülöp, Z; Gyürky, G; Imbriani, G; Lubritto, C; Ordine, A; Roca, V; Rogalla, D; Rolfs, C; Russo, M; Sabbarese, C; Somorjai, E; Strieder, F; Terrasi, F; Trautvetter, H P

    2002-01-01

    A sup 7 Be ion beam of several particle pA at 8 MeV has been produced at the TTT3 tandem of the University 'Federico II' in Naples. The sup 7 Be nuclides were formed via the sup 7 Li(p,n) sup 7 Be reaction using a metallic Li target and an 11.4 MeV proton beam of 20 mu A intensity, delivered by the cyclotron in Debrecen. Methods of hot chemistry were used to extract the sup 7 Be nuclides from the Li matrix and to prepare the sup 7 Be cathodes for the ion sputter source of the tandem. Examples of sup 7 Be beam applications are given.

  13. 5 MeV 300 kW electron accelerator project

    International Nuclear Information System (INIS)

    Auslender, V.L.; Cheskidov, V.G.; Gornakov, I.V.

    2004-01-01

    The paper presents a project of a high power linear accelerator for industrial applications. The accelerator has a modular structure and consists of the chain of accelerating cavities connected by the axis-located coupling cavities with coupling slots in the common walls. Main parameters of the accelerator are: operating frequency of 176 MHz, electron energy of up to 5 MeV, average beam power of 300 kW. The required RF pulse power can be supplied by the TH628 diacrode

  14. Neurosurgical Procedures in Jehovah's Witnesses: The Tema ...

    African Journals Online (AJOL)

    BACKGROUND: On account of religious reasons, Jehovah Witnesses do not accept blood or blood products; occasionally, they accept reinfusion of autologous blood via a cell saver during surgery. OBJECTIVE: The aim of this study was to document the demographics of Jehovah Witnesses undergoing neurosurgical ...

  15. Microprocessor control and data acquisition at the LLNL 100-MeV accelerator

    International Nuclear Information System (INIS)

    Mendonca, M.L.

    1981-01-01

    A distributed microprocessor control and data acquisition network has been designed for implementation on the Lawrence Livermore National Laboratory 100 MeV electron/positron accelerator (LINAC). The system has been designed to be as transparent to the user as possible by stressing responsiveness, reliability, and relevance of data presented to the user. Implementation of the network will take place in modular fashion in three stages, so as to minimize disruption of normal operations. The first elements to be installed will be the beam transport system controls, beam set-up time. Beam diagnostic equipment is now being position monitors, and accelerator operating status monitors. These units will reduce beam set-up time. Beam diagnostic equipment is now being designed that will be used in a second stage implementation. This stage will concentrate on determining beam parameters and allowing the user to optimize the beam for a given parameter. The final stage will be to install experimenter data acquisition equipment. The equipment will augment the presently existing data acquisition system. The completed network will allow a more efficient operation of the LINAC, resulting in reduced experiment costs, and more controllable beam parameters, both of which are major concerns of experimenters

  16. Acquisition and Initial Analysis of H+- and H--Beam Centroid Jitter at LANSCE

    Science.gov (United States)

    Gilpatrick, J. D.; Bitteker, L.; Gulley, M. S.; Kerstiens, D.; Oothoudt, M.; Pillai, C.; Power, J.; Shelley, F.

    2006-11-01

    During the 2005 Los Alamos Neutron Science Center (LANSCE) beam runs, beam current and centroid-jitter data were observed, acquired, analyzed, and documented for both the LANSCE H+ and H- beams. These data were acquired using three beam position monitors (BPMs) from the 100-MeV Isotope Production Facility (IPF) beam line and three BPMs from the Switchyard transport line at the end of the LANSCE 800-MeV linac. The two types of data acquired, intermacropulse and intramacropulse, were analyzed for statistical and frequency characteristics as well as various other correlations including comparing their phase-space like characteristics in a coordinate system of transverse angle versus transverse position. This paper will briefly describe the measurements required to acquire these data, the initial analysis of these jitter data, and some interesting dilemmas these data presented.

  17. Beams dynamics optimisation of LINAC4 structures for increased operational flexibility

    CERN Document Server

    Bellodi, G; Garcia Tudela, M; Hein, L M; Lallement, J B; Lombardi, A M; Posocco, P A; Sargsyan, E; Stovall, J

    2010-01-01

    Linac4 is a new 160 MeV, 40 mA pulsed beam current H- accelerator which will be the source of particles for all proton accelerators at CERN. Construction started in October 2008, and beam commissioning of the 3 MeV front-end is scheduled for early next year. A baseline design of the linac beam dynamics was completed 2 years ago and validated by a systematic campaign of transverse and longitudinal error studies to assess tolerance limits and machine activation levels. Recent studies have been mainly focused on optimising this design to achieve both a smoother performance for nominal beam conditions and to gain operational flexibility for non-nominal scenarios. These include a review of the chopper beam dynamics design, a re-definition of the DTL and CCDTL inter-tank regions and a study of operational schemes for reduced beam currents (either permanent or in pulse-to-pulse mode). These studies have been carried out in parallel to first specifications for a beam commissioning strategy of the linac and its low-en...

  18. Structure modification and medical application of the natural products by proton beam irradiation

    International Nuclear Information System (INIS)

    Lee, D. W.; Park, J. K.; Kang, J. E.; Shin, S. C.; Ahn, J. H.; Lee, E. S.

    2008-04-01

    This study was performed for the investigation of changes of constituent contents of Korean ginseng (Panax genseng C.A. Meyer) after proton beam irradiation (Beam energy from MC-50 cyclotron : 36.5MeV) with beam range of 500 - 10000Gy

  19. Structure modification and medical application of the natural products by proton beam irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Lee, D. W.; Park, J. K.; Kang, J. E.; Shin, S. C.; Ahn, J. H.; Lee, E. S. [Dongguk University, Gyeongju (Korea, Republic of)

    2008-04-15

    This study was performed for the investigation of changes of constituent contents of Korean ginseng (Panax genseng C.A. Meyer) after proton beam irradiation (Beam energy from MC-50 cyclotron : 36.5MeV) with beam range of 500 - 10000Gy

  20. Feasibility of ceramic joining with high energy electron beams

    International Nuclear Information System (INIS)

    Turman, B.N.; Glass, S.J.; Halbleib, J.A.; Helmich, D.R.; Loehman, R.E.; Clifford, J.R.

    1995-01-01

    Joining structural ceramics is possible using high melting point metals such as Mo and Pt that are heated with a high energy electron beam, with the potential for producing joints with high temperature capability. A 10 MeV electron beam can penetrate through 1 cm of ceramic, offering the possibility of buried interface joining. Because of transient heating and the lower heat capacity of the metal relative to the ceramic, a pulsed high power beam has the potential for melting the metal without decomposing or melting the adjacent ceramic. The authors have demonstrated the feasibility of the process with a series of 10 MeV, 1 kW electron beam experiments. Shear strengths up to 28 NTa have been measured for Si 3 N 4 -Mo-Si 3 N 4 . These modest strengths are due to beam non-uniformity and the limited area of bonding. The bonding mechanism appears to be a thin silicide reaction layer. Si 3 N 4 -Si 3 N 4 joints with no metal layer were also produced, apparently bonded an yttrium apatite grain boundary phase