WorldWideScience

Sample records for mev quasi-monoenergetic neutron

  1. Quasi-monoenergetic neutron energy spectra for 246 and 389 MeV (7)Li(p,n) reactions at angles from 0 degrees to 300 degrees

    CERN Document Server

    Iwamoto, Y; Nakamura, T; Nakashima, H; Mares, V; Itoga, T; Matsumoto, T; Nakane, Y; Feldbaumer, E; Jaegerhofer, L; Pioch, C; Tamii, A; Satoh, D; Masuda, A; Sato, T; Iwase, H; Yashima, H; Nishiyama, J; Hagiwara, M; Hatanaka, K; Sakamoto, Y

    2011-01-01

    The authors measured the neutron energy spectra of a quasi-monoenergetic (7)Li(p,n) neutron source with 246 and 389 MeV protons set at seven angles (0 degrees, 2.5 degrees, 5 degrees, 10 degrees, 15 degrees, 20 degrees and 30 degrees), using a time-of-flight (TOF) method employing organic scintillators NE213 at the Research Center for Nuclear Physics (RCNP) of Osaka University. The energy spectra of the source neutrons were precisely deduced down to 2 MeV at 0 degrees and 10 MeV at other angles. The cross-sections of the peak neutron production reaction at 0 degrees were on the 35-40 mb line of other experimental data, and the peak neutron angular distribution agreed well with the Taddeucci formula. Neutron energy spectra below 100 MeV at all angles were comparable, but the shapes of the continuum above 150 MeV changed considerably with the angle. In order to consider the correction required to derive the response in the peak region from the measured total response for high-energy neutron monitors such as DAR...

  2. Experiments on iron shield transmission of quasi-monoenergetic neutrons generated by 43- and 68-MeV protons via the 7Li(p,n) reaction

    International Nuclear Information System (INIS)

    Nakashima, Hiroshi; Tanaka, Shun-ichi; Nakao, Noriaki

    1996-03-01

    In order to provide benchmark data of neutrons transmitted through iron shields in the intermediate-energy region, spatial distributions of neutron energy spectra and reaction rates behind and inside the iron shields of thickness up to 130 cm were measured for 43- and 68-MeVp- 7 Li neutrons using a quasi-monoenergetic neutron beam source at the 90-MV AVF cyclotron facility of the TLARA facility in JAERI. The measured data by five kinds of detectors: the BC501A detector, the Bonner ball counter, 238 U and 232 Th fission counters, 7 LiF and nat LiF TLDs and solid state nuclear track detector, are numerically provided in this report in the energy region between 10 -4 eV and the energy of peak neutrons generated by the 7 Li(p,n) reaction. (author)

  3. Experiments on iron shield transmission of quasi-monoenergetic neutrons generated by 43- and 68-MeV protons via the {sup 7}Li(p,n) reaction

    Energy Technology Data Exchange (ETDEWEB)

    Nakashima, Hiroshi [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment; Tanaka, Shun-ichi; Nakao, Noriaki [and others

    1996-03-01

    In order to provide benchmark data of neutrons transmitted through iron shields in the intermediate-energy region, spatial distributions of neutron energy spectra and reaction rates behind and inside the iron shields of thickness up to 130 cm were measured for 43- and 68-MeVp-{sup 7}Li neutrons using a quasi-monoenergetic neutron beam source at the 90-MV AVF cyclotron facility of the TLARA facility in JAERI. The measured data by five kinds of detectors: the BC501A detector, the Bonner ball counter, {sup 238}U and {sup 232}Th fission counters, {sup 7}LiF and {sup nat}LiF TLDs and solid state nuclear track detector, are numerically provided in this report in the energy region between 10{sup -4} eV and the energy of peak neutrons generated by the {sup 7}Li(p,n) reaction. (author).

  4. Efficiency determination of resistive plate chambers for fast quasi-monoenergetic neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Roeder, M.; Cowan, T.E.; Kempe, M.; Yakorev, D. [Helmholtz-Zentrum Dresden-Rossendorf, Dresden (Germany); Technische Universitaet Dresden, Dresden (Germany); Elekes, Z. [MTA ATOMKI, Debrecen (Hungary); Helmholtz-Zentrum Dresden-Rossendorf, Dresden (Germany); Aumann, T.; Caesar, C. [GSI Helmholtzzentrum fuer Schwerionenforschung, Darmstadt (Germany); Technische Universitaet Darmstadt, Darmstadt (Germany); Bemmerer, D.; Sobiella, M.; Stach, D.; Wagner, A. [Helmholtz-Zentrum Dresden-Rossendorf, Dresden (Germany); Boretzky, K.; Hehner, J.; Heil, M. [GSI Helmholtzzentrum fuer Schwerionenforschung, Darmstadt (Germany); Maroussov, V. [Universitaet zu Koeln, Koeln (Germany); GSI Helmholtzzentrum fuer Schwerionenforschung, Darmstadt (Germany); Nusair, O. [GSI Helmholtzzentrum fuer Schwerionenforschung, Darmstadt (Germany); Al-Balqa Applied University, Salt (Jordan); Prokofiev, A.V. [Uppsala University, The Svedberg Laboratory, Uppsala (Sweden); Reifarth, R. [Johann Wolfgang Goethe - Universitaet, Frankfurt am Main (Germany); Zilges, A. [Universitaet zu Koeln, Koeln (Germany); Zuber, K. [Technische Universitaet Dresden, Dresden (Germany); Collaboration: R3B Collaboration

    2014-07-15

    Composite detectors made of stainless-steel converters and multigap resistive plate chambers have been irradiated with quasi-monoenergetic neutrons with a peak energy of 175 MeV. The neutron detection efficiency has been determined using two different methods. The data are in agreement with the output of Monte Carlo simulations. The simulations are then extended to study the response of a hypothetical array made of these detectors to energetic neutrons from a radioactive ion beam experiment. (orig.)

  5. Neutron-induced fission cross-section measurement of 234U with quasi-monoenergetic beams in the keV and MeV range using micromegas detectors

    Science.gov (United States)

    Tsinganis, A.; Kokkoris, M.; Vlastou, R.; Kalamara, A.; Stamatopoulos, A.; Kanellakopoulos, A.; Lagoyannis, A.; Axiotis, M.

    2017-09-01

    Accurate data on neutron-induced fission cross-sections of actinides are essential for the design of advanced nuclear reactors based either on fast neutron spectra or alternative fuel cycles, as well as for the reduction of safety margins of existing and future conventional facilities. The fission cross-section of 234U was measured at incident neutron energies of 560 and 660 keV and 7.5 MeV with a setup based on `microbulk' Micromegas detectors and the same samples previously used for the measurement performed at the CERN n_TOF facility (Karadimos et al., 2014). The 235U fission cross-section was used as reference. The (quasi-)monoenergetic neutron beams were produced via the 7Li(p,n) and the 2H(d,n) reactions at the neutron beam facility of the Institute of Nuclear and Particle Physics at the `Demokritos' National Centre for Scientific Research. A detailed study of the neutron spectra produced in the targets and intercepted by the samples was performed coupling the NeuSDesc and MCNPX codes, taking into account the energy spread, energy loss and angular straggling of the beam ions in the target assemblies, as well as contributions from competing reactions and neutron scattering in the experimental setup. Auxiliary Monte-Carlo simulations were performed with the FLUKA code to study the behaviour of the detectors, focusing particularly on the reproduction of the pulse height spectra of α-particles and fission fragments (using distributions produced with the GEF code) for the evaluation of the detector efficiency. An overview of the developed methodology and preliminary results are presented.

  6. High-energy quasi-monoenergetic neutron fields: existing facilities and future needs

    CERN Document Server

    Pomp, S; Mayer, S; Reitz, G; Rottger, S; Silari, M; Smit, F D; Vincke, H; Yasuda, H

    2014-01-01

    The argument that well-characterised quasi-monoenergetic neutron (QMN) sources reaching into the energy domain >20 MeV are needed is presented. A brief overview of the existing facilities is given, and a list of key factors that an ideal QMN source for dosimetry and spectrometry should offer is presented. The authors conclude that all of the six QMN facilities currently in existence worldwide operate in sub-optimal conditions for dosimetry. The only currently available QMN facility in Europe capable of operating at energies >40 MeV, TSL in Uppsala, Sweden, is threatened with shutdown in the immediate future. One facility, NFS at GANIL, France, is currently under construction. NFS could deliver QMN beams up to about 30 MeV. It is, however, so far not clear if and when NFS will be able to offer QMN beams or operate with only so-called white neutron beams. It is likely that by 2016, QMN beams with energies >40 MeV will be available only in South Africa and Japan, with none in Europe.

  7. Filtered epithermal quasi-monoenergetic neutron beams at research reactor facilities

    International Nuclear Information System (INIS)

    Mansy, M.S.; Bashter, I.I.; El-Mesiry, M.S.; Habib, N.; Adib, M.

    2015-01-01

    Filtered neutron techniques were applied to produce quasi-monoenergetic neutron beams in the energy range of 1.5–133 keV at research reactors. A simulation study was performed to characterize the filter components and transmitted beam lines. The filtered beams were characterized in terms of the optimal thickness of the main and additive components. The filtered neutron beams had high purity and intensity, with low contamination from the accompanying thermal emission, fast neutrons and γ-rays. A computer code named “QMNB” was developed in the “MATLAB” programming language to perform the required calculations. - Highlights: • Quasi-monoenergetic neutron beams in energy range from (1.5–133) keV. • Interference between the resonance and potential scattering amplitudes. • Epithermal neutron beams used in BNCT

  8. Measurement of activation cross sections for quasi-monoenergetic neutron induced reactions of {sup 89}Y

    Energy Technology Data Exchange (ETDEWEB)

    Zaman, Muhammad; Kim, Guinyun; Kim, Kwangsoo; Nadeem, Muhammad [Kyungpook National University, Department of Physics and Center for High Energy Physics, Daegu (Korea, Republic of); Naik, Haladhara [Kyungpook National University, Department of Physics and Center for High Energy Physics, Daegu (Korea, Republic of); Bhabha Atomic Research Centre, Radiochemistry Division, Mumbai (India); Lee, Manwoo [Dongnam Inst. of Radiological and Medical Sciences, Research Center, Busan (Korea, Republic of)

    2017-09-15

    The neutron induced cross sections of the {sup 89}Y(n, 2n){sup 88}Y, {sup 89}Y(n, 3n){sup 87}Y and {sup 89}Y(n, 4n){sup 86}Y reactions were measured in the neutron energy range of 15.2 to 37.2 MeV by using an activation and off-line γ-ray spectrometric technique. The quasi-monoenergetic neutrons used for the above reactions are based on a {sup 9}Be(p, n) reaction. Simulations of the neutron spectra from the Be target were done using the MCNPX 2.6.0 program. Theoretical calculations were performed for the {sup 89}Y(n, 2n){sup 88}Y, {sup 89}Y(n, 3n){sup 87}Y and {sup 89}Y(n, 4n){sup 86}Y reaction cross sections using nuclear model code Talys 1.8. The measured and calculated cross sections were compared with the literature data given in EXFOR and the TENDL-2015 data libraries. The present data of the {sup 89}Y(n, xn) reaction were also compared with the similar data of the {sup 89}Y(γ, xn) reaction to examine the effect of the entrance channel parameters as well as the role of projectiles and ejectiles. (orig.)

  9. Filtered epithermal quasi-monoenergetic neutron beams at research reactor facilities.

    Science.gov (United States)

    Mansy, M S; Bashter, I I; El-Mesiry, M S; Habib, N; Adib, M

    2015-03-01

    Filtered neutron techniques were applied to produce quasi-monoenergetic neutron beams in the energy range of 1.5-133keV at research reactors. A simulation study was performed to characterize the filter components and transmitted beam lines. The filtered beams were characterized in terms of the optimal thickness of the main and additive components. The filtered neutron beams had high purity and intensity, with low contamination from the accompanying thermal emission, fast neutrons and γ-rays. A computer code named "QMNB" was developed in the "MATLAB" programming language to perform the required calculations. Copyright © 2014 Elsevier Ltd. All rights reserved.

  10. Evaluation of Neutron Response of Criticality Accident Alarm System Detector to Quasi-Monoenergetic 24 keV Neutrons

    Science.gov (United States)

    Tsujimura, Norio; Yoshida, Tadayoshi; Yashima, Hiroshi

    The criticality accident alarm system (CAAS), which was recently developed and installed at the Japan Atomic Energy Agency's Tokai Reprocessing Plant, consists of a plastic scintillator combined with a cadmium-lined polyethylene moderator and thereby responds to both neutrons and gamma rays. To evaluate the neutron absorbed dose rate response of the CAAS detector, a 24 keV quasi-monoenergetic neutron irradiation experiment was performed at the B-1 facility of the Kyoto University Research Reactor. The detector's evaluated neutron response was confirmed to agree reasonably well with prior computer-predicted responses.

  11. Evaluation of neutron response of criticality accident alarm system detector to quasi-monoenergetic 24 keV neutrons

    International Nuclear Information System (INIS)

    Tsujimura, Norio; Yoshida, Tadayoshi; Yashima, Hiroshi

    2016-01-01

    The criticality accident alarm system (CAAS), which was recently developed and installed at the Japan Atomic Energy Agency's Tokai Reprocessing Plant, consists of a plastic scintillator combined with a cadmium-lined polyethylene moderator and thereby responds to both neutrons and gamma rays. To evaluate the neutron absorbed dose rate response of the CAAS detector, a 24 keV quasi-monoenergetic neutron irradiation experiment was performed at the B-1 facility of the Kyoto University Research Reactor. The detector's evaluated neutron response was confirmed to agree reasonably well with prior computer-predicted responses. (author)

  12. Measurement of activation cross sections of the {sup 27}Al(n,α){sup 24}Na and {sup 27}Al(n,p){sup 27}Mg reactions with quasi-monoenergetic neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Zaman, Muhammad; Kim, Guinyun; Kim, Kwangsoo [Kyungpook National Univ., Daegu (Korea, Republic of). Dept. of Physics; Naik, Haladhara [Kyungpook National Univ., Daegu (Korea, Republic of). Dept. of Physics; Bhabha Atomic Research Centre, Mumbai (India). Radiochemistry Div.; Lee, Young-Ouk; Cho, Young-Sik [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of). Nuclear Data Center; Lee, Man Woo; Kang, Yeong-Rok [Dongnam Institute of Radiological and Medical Science, Busan (Korea, Republic of). Research Center

    2017-10-01

    The cross sections of the {sup 27}Al(n,α){sup 24}Na and {sup 27}Al(n,p){sup 27}Mg reactions with the average neutron energies of 15.2, 26.4, and 37.2 MeV were measured using the activation and off-line γ-ray spectrometric technique at the Korean Institute of Radiological and Medical Sciences (KIRAMS), Korea. Quasi-monoenergetic neutrons produced via the {sup 9}Be(p,n) reaction with the proton beam energies of 25, 35, and 45 MeV from the MC50 cyclotron of KIRAMS were used. The present measured values were compared with those from the evaluated nuclear data libraries ENDF/B-VII, TENDL-2015, TALYS 1.8, and from literature. In general, a close agreement with the literature data as well as the evaluated data was found.

  13. The cross-section data from neutron activation experiments on niobium in the NPI p-7Li quasi-monoenergetic neutron field

    Directory of Open Access Journals (Sweden)

    Simakov S.P.

    2010-10-01

    Full Text Available The reaction of protons on 7Li target produces the high-energy quasi- monoenergetic neutron spectrum with the tail to lower energies. Proton energies of 19.8, 25.1, 27.6, 30.1, 32.6, 35.0 and 37.4 MeV were used to obtain quasi-monoenergetic neutrons with energies of 18, 21.6, 24.8, 27.6, 30.3, 32.9 and 35.6 MeV, respectively. Nb cross-section data for neutron energies higher than 22.5 MeV do not exist in the literature. Nb is the important material for fusion applications (IFMIF as well. The variable-energy proton beam of NPI cyclotron is utilized for the production of neutron field using thin lithium target. The carbon backing serves as the beam stopper. The system permits to produce neutron flux density about 109  n/cm2/s in peak at 30 MeV neutron energy. The niobium foils of 15 mm in diameter and approx. 0.75 g weight were activated. The nuclear spectroscopy methods with HPGe detector technique were used to obtain the activities of produced isotopes. The large set of neutron energies used in the experiment allows us to make the complex study of the cross-section values. The reactions (n,2n, (n,3n, (n,4n, (n,He3, (n,α and (n,2nα are studied. The cross-sections data of the (n,4n and (n,2nα are obtained for the first time. The cross-sections of (n,2n and (n,α reactions for higher neutron energies are strongly influenced by low energy tail of neutron spectra. This effect is discussed. The results are compared with the EAF-2007 library.

  14. Measurements of double-differential neutron emission cross sections of Nb and Bi for 11.5 MeV neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Ibaraki, Masanobu; Matsuyama, Shigeo; Soda, Daisuke; Baba, Mamoru; Hirakawa, Naohiro [Tohoku Univ., Sendai (Japan). Faculty of Engineering

    1997-03-01

    Double-differential neutron emission cross sections (DDXs) of Nb and Bi have been measured for 11.5MeV neutrons using the {sup 15N}(d,n){sup 16}O quasi-monoenergetic neutron source at Tohoku University 4.5MV Dynamitron facility. For En`>6MeV, DDXs were measured by the conventional TOF method (single-TOF:S-TOF). For En`<6MeV, where the S-TOF spectra were distorted by the background neutrons, we adopted a double-TOF method (D-TOF). By applying D-TOF method, we obtained DDXs down to 1MeV. (author)

  15. Laser Acceleration of Quasi-Monoenergetic Protons via Radiation Pressure Driven Thin Foil

    International Nuclear Information System (INIS)

    Liu, Chuan S.; Shao Xi; Liu, T. C.; Dudnikova, Galina; Sagdeev, Roald Z.; Eliasson, Bengt

    2011-01-01

    We present a theoretical and simulation study of laser acceleration of quasi-monoenergetic protons in a thin foil irradiated by high intensity laser light. The underlying physics of radiation pressure acceleration (RPA) is discussed, including the importance of optimal thickness and circularly polarized light for efficient acceleration of ions to quasi-monoenergetic beams. Preliminary two-dimensional simulation studies show that certain parameter regimes allow for stabilization of the Rayleigh-Taylor instability and possibility of acceleration of monoenergetic ions to an excess of 200 MeV, making them suitable for important applications such as medical cancer therapy and fast ignition.

  16. Quasi-monoenergetic proton acceleration from cryogenic hydrogen microjet by ultrashort ultraintense laser pulses

    Science.gov (United States)

    Sharma, A.; Tibai, Z.; Hebling, J.; Fülöp, J. A.

    2018-03-01

    Laser-driven proton acceleration from a micron-sized cryogenic hydrogen microjet target is investigated using multi-dimensional particle-in-cell simulations. With few-cycle (20-fs) ultraintense (2-PW) laser pulses, high-energy quasi-monoenergetic proton acceleration is predicted in a new regime. A collisionless shock-wave acceleration mechanism influenced by Weibel instability results in a maximum proton energy as high as 160 MeV and a quasi-monoenergetic peak at 80 MeV for 1022 W/cm2 laser intensity with controlled prepulses. A self-generated strong quasi-static magnetic field is also observed in the plasma, which modifies the spatial distribution of the proton beam.

  17. Measurement of the {sup 234}U(n, f) cross-section with quasi-monoenergetic beams in the keV and MeV range using a Micromegas detector assembly

    Energy Technology Data Exchange (ETDEWEB)

    Stamatopoulos, A.; Kanellakopoulos, A.; Kalamara, A.; Kokkoris, M.; Michalopoulou, V.; Vlastou, R. [National Technical University of Athens, Department of Physics, Athens (Greece); Diakaki, M. [National Technical University of Athens, Department of Physics, Athens (Greece); European Organisation for Nuclear Research (CERN), Geneva (Switzerland); Tsinganis, A. [European Organisation for Nuclear Research (CERN), Geneva (Switzerland); Axiotis, M.; Lagoyiannis, A. [Tandem Accelerator Laboratory, Institute of Nuclear and Particle Physics, N.C.S.R. Demokritos, Athens (Greece)

    2018-01-15

    The {sup 234}U neutron-induced fission cross-section has been measured at incident neutron energies of 452, 550, 651 keV and 7.5, 8.7, 10 MeV using the {sup 7}Li (p, n) and the {sup 2}H(d, n) reactions, respectively, relative to the {sup 235}U(n, f) and {sup 238}U(n, f) reference reactions. The measurement was performed at the neutron beam facility of the National Center for Scientific Research ''Demokritos'', using a set-up based on Micromegas detectors. The active mass of the actinide samples and the corresponding impurities were determined via α-spectroscopy using a surface barrier silicon detector. The neutron spectra intercepted by the actinide samples have been thoroughly studied by coupling the NeuSDesc and MCNP5 codes, taking into account the energy and angular straggling of the primary ion beams in the neutron source targets in addition to contributions from competing reactions (e.g. deuteron break-up) and neutron scattering in the surrounding materials. Auxiliary Monte Carlo simulations were performed making combined use of the FLUKA and GEF codes, focusing particularly on the determination of the fission fragment detection efficiency. The developed methodology and the final results are presented. (orig.)

  18. Measurement of the 234U(n, f ) cross-section with quasi-monoenergetic beams in the keV and MeV range using a Micromegas detector assembly

    Science.gov (United States)

    Stamatopoulos, A.; Kanellakopoulos, A.; Kalamara, A.; Diakaki, M.; Tsinganis, A.; Kokkoris, M.; Michalopoulou, V.; Axiotis, M.; Lagoyiannis, A.; Vlastou, R.

    2018-01-01

    The 234U neutron-induced fission cross-section has been measured at incident neutron energies of 452, 550, 651 keV and 7.5, 8.7, 10 MeV using the 7Li ( p, n) and the 2H( d, n) reactions, respectively, relative to the 235U( n, f ) and 238U( n, f ) reference reactions. The measurement was performed at the neutron beam facility of the National Center for Scientific Research "Demokritos", using a set-up based on Micromegas detectors. The active mass of the actinide samples and the corresponding impurities were determined via α-spectroscopy using a surface barrier silicon detector. The neutron spectra intercepted by the actinide samples have been thoroughly studied by coupling the NeuSDesc and MCNP5 codes, taking into account the energy and angular straggling of the primary ion beams in the neutron source targets in addition to contributions from competing reactions ( e.g. deuteron break-up) and neutron scattering in the surrounding materials. Auxiliary Monte Carlo simulations were performed making combined use of the FLUKA and GEF codes, focusing particularly on the determination of the fission fragment detection efficiency. The developed methodology and the final results are presented.

  19. Laser Radiation Pressure Accelerator for Quasi-Monoenergetic Proton Generation and Its Medical Implications

    Science.gov (United States)

    Liu, C. S.; Shao, X.; Liu, T. C.; Su, J. J.; He, M. Q.; Eliasson, B.; Tripathi, V. K.; Dudnikova, G.; Sagdeev, R. Z.; Wilks, S.; Chen, C. D.; Sheng, Z. M.

    Laser radiation pressure acceleration (RPA) of ultrathin foils of subwavelength thickness provides an efficient means of quasi-monoenergetic proton generation. With an optimal foil thickness, the ponderomotive force of the intense short-pulse laser beam pushes the electrons to the edge of the foil, while balancing the electric field due to charge separation. The electron and proton layers form a self-organized plasma double layer and are accelerated by the radiation pressure of the laser, the so-called light sail. However, the Rayleigh-Taylor instability can limit the acceleration and broaden the energy of the proton beam. Two-dimensional particle-in-cell (PIC) simulations have shown that the formation of finger-like structures due to the nonlinear evolution of the Rayleigh-Taylor instability limits the acceleration and leads to a leakage of radiation through the target by self-induced transparency. We here review the physics of quasi-monoenergetic proton generation by RPA and recent advances in the studies of energy scaling of RPA, and discuss the RPA of multi-ion and gas targets. The scheme for generating quasi-monoenergetic protons with RPA has the potential of leading to table-top accelerators as sources for producing monoenergetic 50-250 MeV protons. We also discuss potential medical implications, such as particle therapy for cancer treatment, using quasi-monoenergetic proton beams generated from RPA. Compact monoenergetic ion sources also have applications in many other areas such as high-energy particle physics, space electronics radiation testing, and fast ignition in laser fusion.

  20. SEE cross section calibration and application to quasi-monoenergetic and spallation facilities

    Directory of Open Access Journals (Sweden)

    Alía Rubén García

    2017-01-01

    Full Text Available We describe an approach to calibrate SEE-based detectors in monoenergetic fields and apply the resulting semi-empiric responses to more general mixed-field cases in which a broad variety of particle species and energy spectra are involved. The calibration of the response functions is based both on experimental proton and neutron data and considerations derived from Monte Carlo simulations using the FLUKA code. The application environments include the quasi-monoenergetic neutrons at RCNP, the atmospheric-like VESUVIO spallation spectrum and the CHARM high-energy accelerator test facility.

  1. Measurements of double differential charged-particle production cross sections for 55, 65, 75 MeV neutrons

    International Nuclear Information System (INIS)

    Hirasawa, Yoshitaka; Baba, Mamoru; Nauchi, Yasushi

    2000-01-01

    We have performed the measurements of double differential charged-particle production cross section ((n,xz)DDXs) of iron and nickel for 55, 65, 75 MeV neutrons using the 7 Li(p,n) quasi-monoenergetic source of TIARA(Takasaki Ion Accelerator for Radiation Application). The experimental data were compared with the LA-150 data library, which agreed generally with the present data. KERMA(Kinetic Energy Released in MAtter) coefficients(of Fe) were deduced from the experimental data and compared with the integral measurement and calculations by the LA-150 data library. (author)

  2. Calculation of X-ray emission produced by a quasi-monoenergetic electron distribution

    International Nuclear Information System (INIS)

    Fanaei, M.; Sadighi-Bonabi, R.

    2010-01-01

    Complete text of publication follows. By using an intense ultrafast laser interaction with plasma, generation of accelerated relativistic electrons with quasi monoenergetic spectrum has been possible. Analytic expressions for spectra and emission efficiencies of x-rays bremsstrahlung and characteristic line emission produced by a quasi-monoenergetic electron distribution from several targets are investigated. In this work, a Gaussian profile is assumed for the quasi-monoenergetic electron spectrum. The produced x-ray radiations are compared with the previous achieved results for a Maxwellian electron profile. These results and achievements are discussed in detail. Also, the outcomes can be evaluated with the experimental and simulated results.

  3. Production and applications of quasi-monoenergetic electron bunches in laser-plasma based accelerators

    International Nuclear Information System (INIS)

    Glinec, Y.; Faure, J.; Ewald, F.; Lifschitz, A.; Malka, V.

    2006-01-01

    Plasmas are attractive media for the next generation of compact particle accelerators because they can sustain electric fields larger than those in conventional accelerators by three orders of magnitude. However, until now, plasma-based accelerators have produced relatively poor quality electron beams even though for most practical applications, high quality beams are required. In particular, beams from laser plasma-based accelerators tend to have a large divergence and very large energy spreads, meaning that different particles travel at different speeds. The combination of these two problems makes it difficult to utilize these beams. Here, we demonstrate the production of high quality and high energy electron beams from laser-plasma interaction: in a distance of 3 mm, a very collimated and quasi-monoenergetic electron beam is emitted with a 0.5 nanocoulomb charge at 170 ± 20 MeV. In this regime, we have observed very nonlinear phenomena, such as self-focusing and temporal self-shortenning down to 10 fs durations. Both phenomena increase the excitation of the wakefield. The laser pulse drives a highly nonlinear wakefield, able to trap and accelerate plasma background electrons to a single energy. We will review the different regimes of electron acceleration and we will show how enhanced performances can be reached with state-of-the-art ultrashort laser systems. Applications such as gamma radiography of such electron beams will also be discussed

  4. Multiple quasi-monoenergetic electron beams from laser-wakefield acceleration with spatially structured laser pulse

    Energy Technology Data Exchange (ETDEWEB)

    Ma, Y.; Li, M. H.; Li, Y. F.; Wang, J. G.; Tao, M. Z.; Han, Y. J.; Zhao, J. R.; Huang, K.; Yan, W. C.; Ma, J. L.; Li, Y. T. [Beijing National Laboratory of Condensed Matter Physics, Institute of Physics, CAS, Beijing 100080 (China); Chen, L. M., E-mail: lmchen@iphy.ac.cn [Beijing National Laboratory of Condensed Matter Physics, Institute of Physics, CAS, Beijing 100080 (China); Department of Physics and Astronomy and IFSA Collaborative Innovation Center, Shanghai Jiao Tong University, Shanghai 200240 (China); Li, D. Z. [Institute of High Energy Physics, CAS, Beijing 100049 (China); Chen, Z. Y. [Institute of Fluid Physics, China Academy of Engineering Physics, Mianyang, Sichuan 621999 (China); Sheng, Z. M. [Department of Physics and Astronomy and IFSA Collaborative Innovation Center, Shanghai Jiao Tong University, Shanghai 200240 (China); Department of Physics, Scottish Universities Physics Alliance, University of Strathclyde, Glasgow G4 0NG (United Kingdom); Zhang, J. [Department of Physics and Astronomy and IFSA Collaborative Innovation Center, Shanghai Jiao Tong University, Shanghai 200240 (China)

    2015-08-15

    By adjusting the focus geometry of a spatially structured laser pulse, single, double, and treble quasi-monoenergetic electron beams were generated, respectively, in laser-wakefield acceleration. Single electron beam was produced as focusing the laser pulse to a single spot. While focusing the laser pulse to two spots that are approximately equal in energy and size and intense enough to form their own filaments, two electron beams were produced. Moreover, with a proper distance between those two focal spots, three electron beams emerged with a certain probability owing to the superposition of the diffractions of those two spots. The energy spectra of the multiple electron beams are quasi-monoenergetic, which are different from that of the large energy spread beams produced due to the longitudinal multiple-injection in the single bubble.

  5. On the quasi-monoenergetic electron beam generation in the laser wakefield acceleration

    International Nuclear Information System (INIS)

    Bulanov, S.V.; Tajima, Toshiki

    2005-01-01

    A new phase of laser acceleration research has entered, as signified by the recent reports in Nature 9/30/05 of the generation of quasi-monoenergetic electron beam by laser wakefield acceleration in three experiments. We survey the current status of experiments and offer their theoretical interpretation. We understand why the choice of parameters is of such importance and why the earlier experiments showed energy spectra far from monoenergy. (author)

  6. Quasi-monoenergetic proton beam produced by cone-top-end target

    International Nuclear Information System (INIS)

    Yu Jinqing; Jin Xiaolin; Li Bin; Zhou Weimin; Gu Yuqiu

    2012-01-01

    A scheme for generating quasi-monoenergetic proton beam is presented. In this paper, a new cone-top-end target is proposed and investigated by two-dimensional particle-in-cell (2D-PIC) simulation. The simulation results show that this target configuration can guide the hot electrons by the self-generated magnetic field along the profile of the cone-top-end target. The peak magnitude of sheath field at the rear surface of solid target can be enhanced, so the proton energy can be improved. The proton beam with energy spread of 9.9% can be obtained. (authors)

  7. Au, Bi, Co and Nb cross-section measured by quasimonoenergetic neutrons from p + Li-7 reaction in the energy range of 18-36 MeV

    Czech Academy of Sciences Publication Activity Database

    Majerle, Mitja; Bém, Pavel; Novák, Jan; Šimečková, Eva; Štefánik, Milan

    2016-01-01

    Roč. 953, SEP (2016), s. 139-157 ISSN 0375-9474 R&D Projects: GA MŠk(CZ) LM2011019 Institutional support: RVO:61389005 Keywords : Quasi-monoenergetic neutron * cross-section Subject RIV: BG - Nuclear , Atomic and Molecular Physics, Colliders Impact factor: 1.916, year: 2016

  8. Ion acceleration in electrostatic collisionless shock: on the optimal density profile for quasi-monoenergetic beams

    Science.gov (United States)

    Boella, E.; Fiúza, F.; Stockem Novo, A.; Fonseca, R.; Silva, L. O.

    2018-03-01

    A numerical study on ion acceleration in electrostatic shock waves is presented, with the aim of determining the best plasma configuration to achieve quasi-monoenergetic ion beams in laser-driven systems. It was recently shown that tailored near-critical density plasmas characterized by a long-scale decreasing rear density profile lead to beams with low energy spread (Fiúza et al 2012 Phys. Rev. Lett. 109 215001). In this work, a detailed parameter scan investigating different plasma scale lengths is carried out. As result, the optimal plasma spatial scale length that allows for minimizing the energy spread while ensuring a significant reflection of ions by the shock is identified. Furthermore, a new configuration where the required profile has been obtained by coupling micro layers of different densities is proposed. Results show that this new engineered approach is a valid alternative, guaranteeing a low energy spread with a higher level of controllability.

  9. Determination of the Ce142(γ,n) cross section using quasi-monoenergetic Compton backscattered γ rays

    Science.gov (United States)

    Sauerwein, A.; Sonnabend, K.; Fritzsche, M.; Glorius, J.; Kwan, E.; Pietralla, N.; Romig, C.; Rusev, G.; Savran, D.; Schnorrenberger, L.; Tonchev, A. P.; Tornow, W.; Weller, H. R.

    2014-03-01

    Background: Knowing the energy dependence of the (γ,n) cross section is mandatory to predict the abundances of heavy elements using astrophysical models. The data can be applied directly or used to constrain the cross section of the inverse (n,γ) reaction. Purpose: The measurement of the reaction Ce142(γ,n)141Ce just above the reaction threshold amends the existing experimental database in that mass region for p-process nucleosynthesis and helps to understand the s-process branching at the isotope Ce141. Method: The quasi-monoenergetic photon beam of the High Intensity γ-ray Source (HIγS), TUNL, USA, is used to irradiate naturally composed Ce targets. The reaction yield is determined afterwards with high-resolution γ-ray spectroscopy. Results: The experimental data are in agreement with previous measurements at higher energies. Since the cross-section prediction of the Ce142(γ,n) reaction is exclusively sensitive to the γ-ray strength function, the resulting cross-section values were compared to Hauser-Feshbach calculations using different γ-ray strength functions. A microscopic description within the framework of the Hartree-Fock-BCS model describes the experimental values well within the measured energy range. Conclusions: The measured data show that the predicted (γ,n) reaction rate is correct within a factor of 2 even though the closed neutron shell N =82 is approached. This agreement allows us to constrain the (n,γ) cross section and to improve the understanding of the s-process branching at Ce141.

  10. 14 MeV neutrons physics and applications

    CERN Document Server

    Valkovic, Vladivoj

    2015-01-01

    Despite the often difficult and time-consuming effort of performing experiments with fast (14 MeV) neutrons, these neutrons can offer special insight into nucleus and other materials because of the absence of charge. 14 MeV Neutrons: Physics and Applications explores fast neutrons in basic science and applications to problems in medicine, the environment, and security.Drawing on his more than 50 years of experience working with 14 MeV neutrons, the author focuses on:Sources of 14 MeV neutrons, including laboratory size accelerators, small and sealed tube generators, well logging sealed tube ac

  11. Generation of quasi-monoenergetic protons from a double-species target driven by the radiation pressure of an ultraintense laser pulse

    Energy Technology Data Exchange (ETDEWEB)

    Pae, Ki Hong [Center for Relativistic Laser Science, Institute for Basic Science, Gwangju 61005 (Korea, Republic of); Kim, Chul Min, E-mail: chulmin@gist.ac.kr [Center for Relativistic Laser Science, Institute for Basic Science, Gwangju 61005 (Korea, Republic of); Advanced Photonics Research Institute, Gwangju Institute of Science and Technology, Gwangju 61005 (Korea, Republic of); Nam, Chang Hee, E-mail: chnam@gist.ac.kr [Center for Relativistic Laser Science, Institute for Basic Science, Gwangju 61005 (Korea, Republic of); Department of Physics and Photon Science, Gwangju Institute of Science and Technology, Gwangju 61005 (Korea, Republic of)

    2016-03-15

    In laser-driven proton acceleration, generation of quasi-monoenergetic proton beams has been considered a crucial feature of the radiation pressure acceleration (RPA) scheme, but the required difficult physical conditions have hampered its experimental realization. As a method to generate quasi-monoenergetic protons under experimentally viable conditions, we investigated using double-species targets of controlled composition ratio in order to make protons bunched in the phase space in the RPA scheme. From a modified optimum condition and three-dimensional particle-in-cell simulations, we showed by varying the ion composition ratio of proton and carbon that quasi-monoenergetic protons could be generated from ultrathin plane targets irradiated with a circularly polarized Gaussian laser pulse. The proposed scheme should facilitate the experimental realization of ultrashort quasi-monoenergetic proton beams for unique applications in high field science.

  12. Energy Dependence of Fission Product Yields from 235U, 238U and 239Pu for Incident Neutron Energies Between 0.5 and 14.8 MeV

    Science.gov (United States)

    Gooden, Matthew; Bredeweg, Todd; Fowler, Malcolm; Vieira, David; Wilhelmy, Jerry; Tonchev, Anton; Stoyer, Mark; Bhike, Megha; Finch, Sean; Krishichayan, Fnu; Tornow, Werner

    2017-09-01

    The energy dependence of a number of cumulative fission product yields (FPY) have been measured using quasi- monoenergetic neutron beams for three actinide targets, 235U, 238U and 239Pu, between 0.5 and 14.8 MeV. The FPYs were measured by a combi- nation of fission counting using specially designed dual-fission chambers and -ray counting. Each dual-fission chamber is a back-to-back ioniza- tion chamber encasing an activation target in the center with thin de- posits of the same target isotope in each chamber. This method allows for the direct measurement of the total number of fissions in the activa- tion target with no reference to the fission cross-section, thus reducing uncertainties. γ-ray counting of the activation target was performed on well-shielded HPGe detectors over a period of 2 months post irradiation to properly identify fission products. Reported are absolute cumulative fission product yields for incident neutron energies of 0.5, 1.37, 2.4, 3.6, 4.6 and 14.8 MeV. New data in the second chance fission region of 5.5 - 9 MeV are included. Work performed for the U.S. Department of Energy by Los Alamos National Security, LLC under Contract DE-AC52-06NA25396.

  13. Cross sections measurement of isomeric states formation in nuclear reactions induced by neutrons of 14 Mev and comparison with statistical theories

    International Nuclear Information System (INIS)

    El Bardouni, T.

    1989-01-01

    Excitation functions of some (n,2n), (n,p) and (n,alpha) reactions on isotopes taken in different mass regions have been measured around 14 Mev. We give more interest to reactions leading to residual nucleus in isomeric states. Quasi-monoenergetic neutrons are produced via the T(d,n)alpha reaction and activation technique is combined to high resolution gamma-ray spectrometry. In the measurement of samples activities, we have scanned carefully the different origins of uncertainties and taken into account all necessary corrections. We have also carried out a detailed study about the nuclear reactions theory (compound nucleus and Geometry Dependent Hybrid Models) in order to compare our measurements results and theoretical calculations. The EMPIRE code (based on compound nucleus and Geometry Dependent Hybrid Models), that we have adapted on IBM Personal Computer, allows us to reproduce with great satisfaction the measured excitation functions without adjusting the models parameters. So we can rely on the EMPIRE code, as it is done in its work, in the prediction of some nuclear reactions excitation functions that cannot be determined by means of activation technique and gamma-ray spectrometry. 88 refs., 43 figs., 16 tabs., 1 chart. (author)

  14. Production of 14 MeV neutrons from D-D neutron generators

    International Nuclear Information System (INIS)

    Cecil, F.E.; Nieschmidt, E.B.

    1986-01-01

    The production of 14 MeV neutrons from a D-D neutron generator resulting from tritium buildup from the d(d,p)t reaction in the target is discussed. The effect of the 14 MeV neutrons on fast neutron activation analysis with D-D neutron generators is evaluated. (orig.)

  15. NeuLAND MRPC-based detector prototypes tested with fast neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Caesar, C., E-mail: c.caesar@gsi.de [GSI Helmholtzzentrum fuer Schwerionenforschung, Darmstadt (Germany); Aumann, T. [GSI Helmholtzzentrum fuer Schwerionenforschung, Darmstadt (Germany); Bemmerer, D. [Forschungszentrum Dresden-Rossendorf, Dresden (Germany); Boretzky, K. [GSI Helmholtzzentrum fuer Schwerionenforschung, Darmstadt (Germany); Elekes, Z. [Forschungszentrum Dresden-Rossendorf, Dresden (Germany); ATOMKI, Debrecen (Hungary); Gonzalez-Diaz, D.; Hehner, J.; Heil, M. [GSI Helmholtzzentrum fuer Schwerionenforschung, Darmstadt (Germany); Kempe, M. [Forschungszentrum Dresden-Rossendorf, Dresden (Germany); Maroussov, V. [Universitaet zu Koeln, Koeln (Germany); Nusair, O. [GSI Helmholtzzentrum fuer Schwerionenforschung, Darmstadt (Germany); Al-Balqa Applied University, Salt (Jordan); Reifarth, R.; Rossi, D.; Simon, H. [GSI Helmholtzzentrum fuer Schwerionenforschung, Darmstadt (Germany); Stach, D.; Wagner, A.; Yakorev, D. [Forschungszentrum Dresden-Rossendorf, Dresden (Germany); Zilges, A. [ATOMKI, Debrecen (Hungary)

    2012-01-01

    Recent results from a first irradiation of multi-gap resistive plate chambers with fast neutrons are presented. The counters have been built at GSI and FZD. The experiment was performed at the 'The Svedberg Laboratory' (TSL) in Uppsala, Sweden, utilizing a quasi-monoenergetic neutron beam with an energy E{sub n}=175 MeV. For a 2 Multiplication-Sign 4 gap prototype operated at E=100 kV/cm, an efficiency of (0.77 {+-}0.33)% was measured.

  16. Dual-fission chamber and neutron beam characterization for fission product yield measurements using monoenergetic neutrons

    Science.gov (United States)

    Bhatia, C.; Fallin, B.; Gooden, M. E.; Howell, C. R.; Kelley, J. H.; Tornow, W.; Arnold, C. W.; Bond, E. M.; Bredeweg, T. A.; Fowler, M. M.; Moody, W. A.; Rundberg, R. S.; Rusev, G.; Vieira, D. J.; Wilhelmy, J. B.; Becker, J. A.; Macri, R.; Ryan, C.; Sheets, S. A.; Stoyer, M. A.; Tonchev, A. P.

    2014-09-01

    A program has been initiated to measure the energy dependence of selected high-yield fission products used in the analysis of nuclear test data. We present out initial work of neutron activation using a dual-fission chamber with quasi-monoenergetic neutrons and gamma-counting method. Quasi-monoenergetic neutrons of energies from 0.5 to 15 MeV using the TUNL 10 MV FM tandem to provide high-precision and self-consistent measurements of fission product yields (FPY). The final FPY results will be coupled with theoretical analysis to provide a more fundamental understanding of the fission process. To accomplish this goal, we have developed and tested a set of dual-fission ionization chambers to provide an accurate determination of the number of fissions occurring in a thick target located in the middle plane of the chamber assembly. Details of the fission chamber and its performance are presented along with neutron beam production and characterization. Also presented are studies on the background issues associated with room-return and off-energy neutron production. We show that the off-energy neutron contribution can be significant, but correctable, while room-return neutron background levels contribute less than <1% to the fission signal.

  17. Applicability of the two-angle differential method to response measurement of neutron-sensitive devices at the RCNP high-energy neutron facility

    Energy Technology Data Exchange (ETDEWEB)

    Masuda, Akihiko, E-mail: aki-masuda@aist.go.jp [National Institute of Advanced Industrial Science and Technology (AIST), 1-1-1 Umezono, Tsukuba, Ibaraki 305-8568 (Japan); Matsumoto, Tetsuro [National Institute of Advanced Industrial Science and Technology (AIST), 1-1-1 Umezono, Tsukuba, Ibaraki 305-8568 (Japan); Iwamoto, Yosuke [Japan Atomic Energy Agency (JAEA), 2-4 Shirakata, Tokai, Naka, Ibaraki 319-1195 (Japan); Hagiwara, Masayuki [High Energy Accelerator Research Organization (KEK), 1-1 Oho, Tsukuba, Ibaraki 305-0801 (Japan); Satoh, Daiki; Sato, Tatsuhiko [Japan Atomic Energy Agency (JAEA), 2-4 Shirakata, Tokai, Naka, Ibaraki 319-1195 (Japan); Iwase, Hiroshi [High Energy Accelerator Research Organization (KEK), 1-1 Oho, Tsukuba, Ibaraki 305-0801 (Japan); Yashima, Hiroshi [Research Reactor Institute, Kyoto University, 2-1010 Asashiro-nishi, Kumatori, Sennan, Osaka 590-0494 (Japan); Nakane, Yoshihiro [Japan Atomic Energy Agency (JAEA), 2-4 Shirakata, Tokai, Naka, Ibaraki 319-1195 (Japan); Nishiyama, Jun [Tokyo Institute of Technology, 2-12-1 Ookayama, Meguro, Tokyo 152-8550 (Japan); Shima, Tatsushi; Tamii, Atsushi; Hatanaka, Kichiji [Research Center for Nuclear Physics (RCNP), Osaka University, 10-1 Mihogaoka, Ibaraki, Osaka 567-0047 (Japan); Harano, Hideki [National Institute of Advanced Industrial Science and Technology (AIST), 1-1-1 Umezono, Tsukuba, Ibaraki 305-8568 (Japan); Nakamura, Takashi [Cyclotron and Radioisotope Center (CYRIC), Tohoku University, 6-3 Aramaki, Aoba, Sendai, Miyagi 980-8578 (Japan)

    2017-03-21

    Quasi-monoenergetic high-energy neutron fields induced by {sup 7}Li(p,n) reactions are used for the response evaluation of neutron-sensitive devices. The quasi-monoenergetic high-energy field consists of high-energy monoenergetic peak neutrons and unwanted continuum neutrons down to the low-energy region. A two-angle differential method has been developed to compensate for the effect of the continuum neutrons in the response measurements. In this study, the two-angle differential method was demonstrated for Bonner sphere detectors, which are typical examples of moderator-based neutron-sensitive detectors, to investigate the method's applicability and its dependence on detector characteristics. Experiments were performed under 96–387 MeV quasi-monoenergetic high-energy neutron fields at the Research Center for Nuclear Physics (RCNP), Osaka University. The measurement results for large high-density polyethylene (HDPE) sphere detectors agreed well with Monte Carlo calculations, which verified the adequacy of the two-angle differential method. By contrast, discrepancies were observed in the results for small HDPE sphere detectors and metal-induced sphere detectors. The former indicated that detectors that are particularly sensitive to low-energy neutrons may be affected by penetrating neutrons owing to the geometrical features of the RCNP facility. The latter discrepancy could be consistently explained by a problem in the evaluated cross-section data for the metals used in the calculation. Through those discussions, the adequacy of the two-angle differential method was experimentally verified, and practical suggestions were made pertaining to this method.

  18. Review of neutron data: 10 to 40 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Haight, R.C.

    1977-04-01

    Neutron data are reviewed for incident neutron energies between 10 and 40 MeV. A census of the data shows that there are many gaps in this range and that the existing data are primarily for neutron energies around 14 MeV. Aside from total cross sections, there are few data between 10 and 13 MeV and between 15 and 40 MeV. Examples are presented to show the quality of selected data for total, elastic, inelastic, activation, and charged-particle and gamma-ray production cross sections. The spectra of emitted particles are also discussed.

  19. Review of neutron data: 10 to 40 MeV

    International Nuclear Information System (INIS)

    Haight, R.C.

    1977-04-01

    Neutron data are reviewed for incident neutron energies between 10 and 40 MeV. A census of the data shows that there are many gaps in this range and that the existing data are primarily for neutron energies around 14 MeV. Aside from total cross sections, there are few data between 10 and 13 MeV and between 15 and 40 MeV. Examples are presented to show the quality of selected data for total, elastic, inelastic, activation, and charged-particle and gamma-ray production cross sections. The spectra of emitted particles are also discussed

  20. Broad Energy Range Neutron Spectroscopy using a Liquid Scintillator and a Proportional Counter: Application to a Neutron Spectrum Similar to that from an Improvised Nuclear Device.

    Science.gov (United States)

    Xu, Yanping; Randers-Pehrson, Gerhard; Marino, Stephen A; Garty, Guy; Harken, Andrew; Brenner, David J

    2015-09-11

    A novel neutron irradiation facility at the Radiological Research Accelerator Facility (RARAF) has been developed to mimic the neutron radiation from an Improvised Nuclear Device (IND) at relevant distances (e.g. 1.5 km) from the epicenter. The neutron spectrum of this IND-like neutron irradiator was designed according to estimations of the Hiroshima neutron spectrum at 1.5 km. It is significantly different from a standard reactor fission spectrum, because the spectrum changes as the neutrons are transported through air, and it is dominated by neutron energies from 100 keV up to 9 MeV. To verify such wide energy range neutron spectrum, detailed here is the development of a combined spectroscopy system. Both a liquid scintillator detector and a gas proportional counter were used for the recoil spectra measurements, with the individual response functions estimated from a series of Monte Carlo simulations. These normalized individual response functions were formed into a single response matrix for the unfolding process. Several accelerator-based quasi-monoenergetic neutron source spectra were measured and unfolded to test this spectroscopy system. These reference neutrons were produced from two reactions: T(p,n) 3 He and D(d,n) 3 He, generating neutron energies in the range between 0.2 and 8 MeV. The unfolded quasi-monoenergetic neutron spectra indicated that the detection system can provide good neutron spectroscopy results in this energy range. A broad-energy neutron spectrum from the 9 Be(d,n) reaction using a 5 MeV deuteron beam, measured at 60 degrees to the incident beam was measured and unfolded with the evaluated response matrix. The unfolded broad neutron spectrum is comparable with published time-of-flight results. Finally, the pair of detectors were used to measure the neutron spectrum generated at the RARAF IND-like neutron facility and a comparison is made to the neutron spectrum of Hiroshima.

  1. Energy dependence of fission product yields from 235U, 238U, and 239Pu with monoenergetic neutrons between thermal and 14.8 MeV

    Science.gov (United States)

    Gooden, Matthew; Arnold, Charles; Bhike, Megha; Bredeweg, Todd; Fowler, Malcolm; Krishichayan; Tonchev, Anton; Tornow, Werner; Stoyer, Mark; Vieira, David; Wilhelmy, Jerry

    2017-09-01

    Under a joint collaboration between TUNL-LANL-LLNL, a set of absolute fission product yield measurements has been performed. The energy dependence of a number of cumulative fission product yields (FPY) have been measured using quasi-monoenergetic neutron beams for three actinide targets, 235U, 238U and 239Pu, between 0.5 and 14.8 MeV. The FPYs were measured by a combination of fission counting using specially designed dual-fission chambers and γ-ray counting. Each dual-fission chamber is a back-to-back ionization chamber encasing an activation target in the center with thin deposits of the same target isotope in each chamber. This method allows for the direct measurement of the total number of fissions in the activation target with no reference to the fission cross-section, thus reducing uncertainties. γ-ray counting of the activation target was performed on well-shielded HPGe detectors over a period of two months post irradiation to properly identify fission products. Reported are absolute cumulative fission product yields for incident neutron energies of 0.5, 1.37, 2.4, 3.6, 4.6, 5.5, 7.5, 8.9 and 14.8 MeV. Preliminary results from thermal irradiations at the MIT research reactor will also be presented and compared to present data and evaluations. This work was performed under the auspices of the U.S. Department of Energy by Los Alamos National Security, LLC under contract DE-AC52-06NA25396, Lawrence Livermore National Laboratory under contract DE-AC52-07NA27344 and by Duke University and Triangle Universities Nuclear Laboratory through NNSA Stewardship Science Academic Alliance grant No. DE-FG52-09NA29465, DE-FG52-09NA29448 and Office of Nuclear Physics Grant No. DE-FG02-97ER41033.

  2. Neutron transmission benchmark problems for iron and concrete shields in low, intermediate and high energy proton accelerator facilities

    Energy Technology Data Exchange (ETDEWEB)

    Nakane, Yoshihiro; Sakamoto, Yukio [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment; Hayashi, Katsumi [and others

    1996-09-01

    Benchmark problems were prepared for evaluating the calculation codes and the nuclear data for accelerator shielding design by the Accelerator Shielding Working Group of the Research Committee on Reactor Physics in JAERI. Four benchmark problems: transmission of quasi-monoenergetic neutrons generated by 43 MeV and 68 MeV protons through iron and concrete shields at TIARA of JAERI, neutron fluxes in and around an iron beam stop irradiated by 500 MeV protons at KEK, reaction rate distributions inside a thick concrete shield irradiated by 6.2 GeV protons at LBL, and neutron and hadron fluxes inside an iron beam stop irradiated by 24 GeV protons at CERN are compiled in this document. Calculational configurations and neutron reaction cross section data up to 500 MeV are provided. (author)

  3. Development of integrated-type dosimeter responsive to high energy neutrons (2)

    Energy Technology Data Exchange (ETDEWEB)

    Sawamura, Teruko; Murai, Ikuo; Abe, Masashi; Uoyama, Kazuya; Das, Mala [Hokkaido Univ., Sapporo, Hokkaido (Japan); Tuda, Shuichi [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    2003-03-01

    The response of superheated drop detectors or bubble detectors (BDs) was measured for quasi-monoenergetic neutron beams in the 40-75 MeV range. The experiments were performed at the AVF cyclotron facility, TAKASAKI Ion Accelerator for Advanced Radiation Application (TIARA) of Japan Atomic Energy Research Institute (JAERI). The measured dose sensitivities showed to be lowered to about a half the nominal sensitivity. A lead-breeder introduced to extend response to the high energy region were investigated and compared with Monte Carlo calculations by MCNPX code. (author)

  4. Production of radionuclides by 14 MeV neutron generator

    International Nuclear Information System (INIS)

    Alfassi, Z.B.

    1983-01-01

    Due to the short half-lives of these nuclides they have to be produced in situ or at least not far from the place of use. The cost of 14 MeV neutron generators have been compared with the typical middle-sized cyclotrons and it was found that the capital costs are much lower in the case of neutron generators. This is the main reason for the availability of 14 MeV neutron generators in many scientific institutes compared to the scarcity of cyclotrons. Lately, the use of 14 MeV neutrons for cancer therapy was studied in several medical centers. A number of hospitals and cancer research centers have high intensity 14 MeV neutron generators for this purpose. The advantages of using short-lived in-house produced radionuclides suggest the use of the available 14 MeV neutron generators for biological studies and in medical diagnosis. 14 MeV neutron generators can be used to produce some of the medically useful radionuclides, such as /sup 18/F, /sup 80/Br, /sup 199m/Hg, and others. However, the amount required for medicine can only be prepared by the new high intensity neutron generators, used for neutron therapy and not by the smaller ones, commonly used in university laboratories (--10/sup 11/ n/sec). On the other hand, these relatively small neutron generators can be used for the preparation of radionuclides for biological studies. They facilitate the study of metabolism of elements for which radionuclides cannot be usually purchased due to short half-lives or the high price of the long-lived ones, such as /sup 34m/Cl, /sup 18/F, /sup 28,29/Al, /sup 27/Mg, and others. An example is the work done on the fate of Al and Mg in rats using /sup 28/Al and /sup 27/Mg./sup 13/

  5. A Bayesian method to estimate the neutron response matrix of a single crystal CVD diamond detector

    International Nuclear Information System (INIS)

    Reginatto, Marcel; Araque, Jorge Guerrero; Nolte, Ralf; Zbořil, Miroslav; Zimbal, Andreas; Gagnon-Moisan, Francis

    2015-01-01

    Detectors made from artificial chemical vapor deposition (CVD) single crystal diamond are very promising candidates for applications where high resolution neutron spectrometry in very high neutron fluxes is required, for example in fusion research. We propose a Bayesian method to estimate the neutron response function of the detector for a continuous range of neutron energies (in our case, 10 MeV ≤ E n ≤ 16 MeV) based on a few measurements with quasi-monoenergetic neutrons. This method is needed because a complete set of measurements is not available and the alternative approach of using responses based on Monte Carlo calculations is not feasible. Our approach uses Bayesian signal-background separation techniques and radial basis function interpolation methods. We present the analysis of data measured at the PTB accelerator facility PIAF. The method is quite general and it can be applied to other particle detectors with similar characteristics

  6. Measurement of {sup 232}Th(n, 5nγ) cross sections from 29 MeV to 42 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Kerveno, M.; Baumann, P.; Dessagne, P.; Rudolf, G. [Universite de Strasbourg, IPHC, Strasbourg (France); CNRS, UMR7178, Strasbourg (France); Nolte, R.; Reginatto, M. [Physikalisch-Technische Bundesanstalt, Braunschweig (Germany); Jericha, E. [Technische Universitaet Wien, Atominstitut, Wien (Austria); Jokic, S.; Lukic, S. [Vinca Institute of Nuclear Sciences, Belgrade (Serbia); Koning, A.J. [Nuclear Research and Consultancy Group, Petten (Netherlands); Meulders, J.P. [Institut de Physique Nucleaire, Louvain-la-Neuve (Belgium); Nachab, A. [Universite Cadi Ayyad, Departement de physique, Faculte Poly-disciplinaire de Safi, Safi (Morocco); Pavlik, A. [Faculty of Physics, University of Vienna, Wien (Austria)

    2014-10-15

    The excitation function of the reaction {sup 232} Th(n, 5nγ){sup 228} Th from 29 to 42 MeV has been measured for the first time at the quasi-monoenergetic neutron beam of the UCL cyclotron CYCLONE employing the {sup 7}Li(p,n) source reaction. Taking advantage of the good energy resolution of the planar High-Purity Germanium (HPGe) detectors, prompt γ-ray spectroscopy was used to detect the γ-rays resulting from the decay of excited states of nuclei created by the (n,xn) reactions. The neutron beam was characterized by a combination of time of flight measurements carried out using a liquid scintillation detector and a {sup 238}U fission ionization chamber. Fluence measurements were performed using a proton recoil telescope. The results are compared with TALYS-1.4 code calculations. (orig.)

  7. Calculations of accelerator-based neutron sources characteristics

    International Nuclear Information System (INIS)

    Tertytchnyi, R.G.; Shorin, V.S.

    2000-01-01

    Accelerator-based quasi-monoenergetic neutron sources (T(p,n), D(d;n), T(d;n) and Li (p,n)-reactions) are widely used in experiments on measuring the interaction cross-sections of fast neutrons with nuclei. The present work represents the code for calculation of the yields and spectra of neutrons generated in (p, n)- and ( d; n)-reactions on some targets of light nuclei (D, T; 7 Li). The peculiarities of the stopping processes of charged particles (with incident energy up to 15 MeV) in multilayer and multicomponent targets are taken into account. The code version is made in terms of the 'SOURCE,' a subroutine for the well-known MCNP code. Some calculation results for the most popular accelerator- based neutron sources are given. (authors)

  8. Compact quasi-monoenergetic photon sources from laser-plasma accelerators for nuclear detection and characterization

    Energy Technology Data Exchange (ETDEWEB)

    Geddes, Cameron G.R., E-mail: cgrgeddes@lbl.gov; Rykovanov, Sergey; Matlis, Nicholas H.; Steinke, Sven; Vay, Jean-Luc; Esarey, Eric H.; Ludewigt, Bernhard; Nakamura, Kei; Quiter, Brian J.; Schroeder, Carl B.; Toth, Csaba; Leemans, Wim P.

    2015-05-01

    Near-monoenergetic photon sources at MeV energies offer improved sensitivity at greatly reduced dose for active interrogation, and new capabilities in treaty verification, nondestructive assay of spent nuclear fuel and emergency response. Thomson (also referred to as Compton) scattering sources are an established method to produce appropriate photon beams. Applications are however restricted by the size of the required high-energy electron linac, scattering (photon production) system, and shielding for disposal of the high energy electron beam. Laser-plasma accelerators (LPAs) produce GeV electron beams in centimeters, using the plasma wave driven by the radiation pressure of an intense laser. Recent LPA experiments are presented which have greatly improved beam quality and efficiency, rendering them appropriate for compact high-quality photon sources based on Thomson scattering. Designs for MeV photon sources utilizing the unique properties of LPAs are presented. It is shown that control of the scattering laser, including plasma guiding, can increase photon production efficiency. This reduces scattering laser size and/or electron beam current requirements to scale compatible with the LPA. Lastly, the plasma structure can decelerate the electron beam after photon production, reducing the size of shielding required for beam disposal. Together, these techniques provide a path to a compact photon source system.

  9. Quasi-monoenergetic ion beam acceleration by laser-driven shock and solitary waves in near-critical plasmas

    International Nuclear Information System (INIS)

    Zhang, W. L.; Qiao, B.; Huang, T. W.; Shen, X. F.; You, W. Y.; Yan, X. Q.; Wu, S. Z.; Zhou, C. T.; He, X. T.

    2016-01-01

    Ion acceleration in near-critical plasmas driven by intense laser pulses is investigated theoretically and numerically. A theoretical model has been given for clarification of the ion acceleration dynamics in relation to different laser and target parameters. Two distinct regimes have been identified, where ions are accelerated by, respectively, the laser-induced shock wave in the weakly driven regime (comparatively low laser intensity) and the nonlinear solitary wave in the strongly driven regime (comparatively high laser intensity). Two-dimensional particle-in-cell simulations show that quasi-monoenergetic proton beams with a peak energy of 94.6 MeV and an energy spread 15.8% are obtained by intense laser pulses at intensity I_0 = 3 × 10"2"0" W/cm"2 and pulse duration τ = 0.5 ps in the strongly driven regime, which is more advantageous than that got in the weakly driven regime. In addition, 233 MeV proton beams with narrow spread can be produced by extending τ to 1.0 ps in the strongly driven regime.

  10. Quasi-monoenergetic ion beam acceleration by laser-driven shock and solitary waves in near-critical plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, W. L.; Qiao, B., E-mail: bqiao@pku.edu.cn; Huang, T. W.; Shen, X. F.; You, W. Y. [Center for Applied Physics and Technology, HEDPS, and State Key Laboratory of Nuclear Physics and Technology, School of Physics, Peking University, Beijing 100871 (China); Collaborative Innovation Center of Extreme Optics, Shanxi University, Taiyuan, Shanxi 030006 (China); Yan, X. Q. [Center for Applied Physics and Technology, HEDPS, and State Key Laboratory of Nuclear Physics and Technology, School of Physics, Peking University, Beijing 100871 (China); Wu, S. Z. [Institute of Applied Physics and Computational Mathematics, Beijing 100094 (China); Zhou, C. T.; He, X. T. [Center for Applied Physics and Technology, HEDPS, and State Key Laboratory of Nuclear Physics and Technology, School of Physics, Peking University, Beijing 100871 (China); Institute of Applied Physics and Computational Mathematics, Beijing 100094 (China)

    2016-07-15

    Ion acceleration in near-critical plasmas driven by intense laser pulses is investigated theoretically and numerically. A theoretical model has been given for clarification of the ion acceleration dynamics in relation to different laser and target parameters. Two distinct regimes have been identified, where ions are accelerated by, respectively, the laser-induced shock wave in the weakly driven regime (comparatively low laser intensity) and the nonlinear solitary wave in the strongly driven regime (comparatively high laser intensity). Two-dimensional particle-in-cell simulations show that quasi-monoenergetic proton beams with a peak energy of 94.6 MeV and an energy spread 15.8% are obtained by intense laser pulses at intensity I{sub 0} = 3 × 10{sup 20 }W/cm{sup 2} and pulse duration τ = 0.5 ps in the strongly driven regime, which is more advantageous than that got in the weakly driven regime. In addition, 233 MeV proton beams with narrow spread can be produced by extending τ to 1.0 ps in the strongly driven regime.

  11. Neutron-neutron quasifree scattering in nd breakup at 10 MeV

    Directory of Open Access Journals (Sweden)

    Malone R.C.

    2016-01-01

    We are conducting new measurements of the cross section for nn QFS in nd breakup. The measurements are performed at incident neutron beam energies below 20 MeV. The neutron beam is produced via the 2H(d, n3He reaction. The target is a deuterated plastic cylinder. Our measurements utilize time-of-flight techniques with a pulsed neutron beam and detection of the two emitted neutrons in coincidence. A description of our initial measurements at 10 MeV for a single scattering angle will be presented along with preliminary results. Also, plans for measurements at other energies with broad angular coverage will be discussed.

  12. Physics and Novel Schemes of Laser Radiation Pressure Acceleration for Quasi-monoenergetic Proton Generation

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Chuan S. [Univ. of Maryland, College Park, MD (United States). Dept. of Physics; Shao, Xi [Univ. of Maryland, College Park, MD (United States)

    2016-06-14

    The main objective of our work is to provide theoretical basis and modeling support for the design and experimental setup of compact laser proton accelerator to produce high quality proton beams tunable with energy from 50 to 250 MeV using short pulse sub-petawatt laser. We performed theoretical and computational studies of energy scaling and Raleigh--Taylor instability development in laser radiation pressure acceleration (RPA) and developed novel RPA-based schemes to remedy/suppress instabilities for high-quality quasimonoenergetic proton beam generation as we proposed. During the project period, we published nine peer-reviewed journal papers and made twenty conference presentations including six invited talks on our work. The project supported one graduate student who received his PhD degree in physics in 2013 and supported two post-doctoral associates. We also mentored three high school students and one undergraduate student of physics major by inspiring their interests and having them involved in the project.

  13. Measurements of neutron spallation cross section. 2

    Energy Technology Data Exchange (ETDEWEB)

    Kim, E.; Nakamura, T. [Tohoku Univ., Sendai (Japan). Cyclotron and Radioisotope Center; Imamura, M.; Nakao, N.; Shibata, S.; Uwamino, Y.; Nakanishi, N.; Tanaka, Su.

    1997-03-01

    Neutron spallation cross section of {sup 59}Co(n,xn){sup 60-x}Co, {sup nat}Cu(n,sp){sup 56}Mn, {sup nat}Cu(n,sp){sup 58}Co, {sup nat}Cu(n,xn){sup 60}Cu, {sup nat}Cu(n,xn){sup 61}Cu and {sup nat}Cu(n,sp){sup 65}Ni was measured in the quasi-monoenergetic p-Li neutron fields in the energy range above 40 MeV which have been established at three AVF cyclotron facilities of (1) INS of Univ. of Tokyo, (2) TIARA of JAERI and (3) RIKEN. Our experimental data were compared with the ENDF/B-VI high energy file data by Fukahori and the calculated cross section data by Odano. (author)

  14. Zone plate imaging of 14-MeV neutrons

    International Nuclear Information System (INIS)

    Lerche, R.A.; Lane, S.M.; Hawryluk, A.M.; Ceglio, N.M.

    1986-01-01

    At Livermore we are interested in imaging the thermonuclear burn region of fusion targets irradiated at our Nova laser facility. We expect compressed core diameters to be 10's of microns, and would like images with better than 10-μm resolution. Alpha particle images provided the first direct information about the thermonuclear burn geometry in thin walled exploding pusher targets. In future high density target experiments, only highly penetrating radiations like the 14-MeV neutrons will escape the target core to provide information about the burn region. To make the measurement with a neutron ''pinhole'' camera requires a 10μm pinhole through about 10 cm of material and 10 14 to 10 15 source neutrons. Penumbral imaging offers some improvement over a pinhole. Zone plate coded imaging (ZPCI) techniques are particularly well suited for imaging small objects like the compressed core of a laser fusion target. We have been using ZPCI techniques to image nonpenetrating radiations like x rays and alpha particles for about 10 years. The techniques are well developed. Imaging penetrating radiations like 14-MeV neutrons using ZPCI techniques has several possible advantages. The large solid angle subtended by the Zone plate might substantially reduce the required target neutron yield needed to produce a useful image, and a neutron zone plate system with 10-μm resolution might be easier to fabricate and characterize than a pinhole system. This paper explores the use of ZPCI techniques with penetrating radiation

  15. Study of particle size distribution and formation mechanism of radioactive aerosols generated in high-energy neutron fields

    CERN Document Server

    Endo, A; Noguchi, H; Tanaka, S; Iida, T; Furuichi, S; Kanda, Y; Oki, Y

    2003-01-01

    The size distributions of sup 3 sup 8 Cl, sup 3 sup 9 Cl, sup 8 sup 2 Br and sup 8 sup 4 Br aerosols generated by irradiations of argon and krypton gases containing di-octyl phthalate (DOP) aerosols with 45 MeV and 65 MeV quasi-monoenergetic neutrons were measured in order to study the formation mechanism of radioactive particles in high energy radiation fields. The effects of the size distribution of the radioactive aerosols on the size of the added DOP aerosols, the energy of the neutrons and the kinds of nuclides were studied. The observed size distributions of the radioactive particles were explained by attachment of the radioactive atoms generated by the neutron-induced reactions to the DOP aerosols. (author)

  16. The shielding of a 14 MeV neutron generator

    International Nuclear Information System (INIS)

    Brighton, D.R.

    1976-10-01

    The concrete masonry shield for a 14 MeV neutron generator was designed using data supplied by the manufacturer. Subsequent radiation surveys outside the shield showed doses higher than expected. Calculations indicated the sensitivity of dose transmission factors to concrete composition. The observed dose transmission factor agreed with that of Broerse but not with that of Hacke and Prudhomme. Measurements and calculations delineated the contribution that neutrons, scattered from the upper wall that supports the laboratory roof, made to the dose in adjoining areas. In redesigning the shield a compromise was made between additional cost and restrictions on the generator's duty cycle, which is automatically controlled to ensure personnel safety. (Author)

  17. High resolution 14 MeV neutron spectrometer

    International Nuclear Information System (INIS)

    Pillon, M.

    1986-01-01

    A neutron spectrometer, based both on the track position identification and the energy measurement of recoiling protons from a hydrogenous radiator is proposed. The expected performance limits of this spectrometer with regard to energy resolution (deltaE/E), efficiency (epsilon) and counting rate are evaluated in five different configurations. The results show the possibility of deriving an optimized spectrometer design for applications on large fusion devices such as JET and NET with an energy resolution up 1% at 14 MeV

  18. Little Boy neutron spectrum below 3 MeV

    International Nuclear Information System (INIS)

    Evans, A.E.; Bennett, E.F.; Yule, T.J.

    1984-01-01

    The leakage neutron spectrum from the Little Boy replica has been measured from 12 keV to 3 MeV using a high-resolution 3 He ionization chamber, and from 1 keV to 3 MeV using proton-recoil proportional counters. The 3 He-spectrometer measurements were made at distances of 0.75 and 2.0 m from the active center and at angles of 0 0 , 45 0 , and 90 0 with respect to the axis of the assembly. Proton-recoil measurments were made at 90 0 to the assembly axis at distances of 0.75 and 2.0 m, with a shielded measurement made at 2.0 m to estimate background due to scattering. The 3 He spectrometer was calibrated at Los Alamos using monoenergetic 7 Li(p,n) 7 Be neutrons to generate a family of response functions. The proton-recoil counters were calibrated at Argonne by studying the capture of thermal neutrons by nitrogen in the counters, by observation of the 24-keV neutron resonance in iron, and by relating to the known hydrogen content of the counters. The neutron spectrum from Little Boy was found to be highly structured, with peaks corresponding to minima in the iron total neutron cross section. In particular, influence of the 24-keV iron window was evident in both sets of spectra. The measurements provide information for dosimetry calculations and also a valuable intercomparison of neutron spectrometry using the two different detector types. Spectra measured with both detectors are in essential agreement. 8 references, 7 figures, 2 tables

  19. SIMULATED 8 MeV NEUTRON RESPONSE FUNCTIONS OF A THIN SILICON NEUTRON SENSOR.

    Science.gov (United States)

    Takada, Masashi; Matsumoto, Tetsuro; Masuda, Akihiko; Nunomiya, Tomoya; Aoyama, Kei; Nakamura, Takashi

    2017-12-22

    Neutron response functions of a thin silicon neutron sensor are simulated using PHITS2 and MCNP6 codes for an 8 MeV neutron beam at angles of incidence of 0°, 30° and 60°. The contributions of alpha particles created from the 28Si(n,α)25Mg reaction and the silicon nuclei scattered elastically by neutrons in the silicon sensor have not been well reproduced using the MCNP6 code. The 8 MeV neutron response functions simulated using the PHITS2 code with an accurate event generator mode are in good agreement with experimental results and include the contributions of the alpha particles and silicon nuclei. © The Author(s) 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  20. Ionizing Energy Depositions After Fast Neutron Interactions in Silicon

    CERN Document Server

    Bergmann, Benedikt; Caicedo, Ivan; Kierstead, James; Takai, Helio; Frojdh, Erik

    2016-01-01

    In this study we present the ionizing energy depositions in a 300 μm thick silicon layer after fast neutron impact. With the Time-of-Flight (ToF) technique, the ionizing energy deposition spectra of recoil silicons and secondary charged particles were assigned to (quasi-)monoenergetic neutron energies in the range from 180 keV to hundreds of MeV. We show and interpret representative measured energy spectra. By separating the ionizing energy losses of the recoil silicon from energy depositions by products of nuclear reactions, the competition of ionizing (IEL) and non-ionizing energy losses (NIEL) of a recoil silicon within the silicon lattice was investigated. The data give supplementary information to the results of a previous measurement and are compared with different theoretical predictions.

  1. The Karlsruhe Neutron Transmission Experiment (KANT): Spherical shell transmission measurements with 14 MeV neutrons on beryllium

    International Nuclear Information System (INIS)

    Moellendorff, U. von; Fischer, U.; Giese, H.; Kappler, F.; Tayama, R.; Wiegner, E.; Klein, H.; Alevra, A.

    1996-01-01

    This is a set of viewgraphs (no additional text) of a presentation on spherical shell transmission measurements with 14 MeV neutrons on beryllium; the cross for 9 Be(n,2n)2α for the energy range between threshold (1.85 MeV) and 20 MeV neutron energy is measured and the measurement is compared with the literature. Also, neutron leakage multiplication in spherical Be shells with various thicknesses are presented. Figs, tabs

  2. Neutron-neutron quasifree scattering in nd breakup at 10 MeV

    Science.gov (United States)

    Malone, R. C.; Crowe, B.; Crowell, A. S.; Cumberbatch, L. C.; Esterline, J. H.; Fallin, B. A.; Friesen, F. Q. L.; Han, Z.; Howell, C. R.; Markoff, D.; Ticehurst, D.; Tornow, W.; Witała, H.

    2016-03-01

    The neutron-deuteron (nd) breakup reaction provides a rich environment for testing theoretical models of the neutron-neutron (nn) interaction. Current theoretical predictions based on rigorous ab-initio calculations agree well with most experimental data for this system, but there remain a few notable discrepancies. The cross section for nn quasifree (QFS) scattering is one such anomaly. Two recent experiments reported cross sections for this particular nd breakup configuration that exceed theoretical calculations by almost 20% at incident neutron energies of 26 and 25 MeV [1, 2]. The theoretical values can be brought into agreement with these results by increasing the strength of the 1S0 nn potential matrix element by roughly 10%. However, this modification of the nn effective range parameter and/or the 1S0 scattering length causes substantial charge-symmetry breaking in the nucleon-nucleon force and suggests the possibility of a weakly bound di-neutron state [3]. We are conducting new measurements of the cross section for nn QFS in nd breakup. The measurements are performed at incident neutron beam energies below 20 MeV. The neutron beam is produced via the 2H(d, n)3He reaction. The target is a deuterated plastic cylinder. Our measurements utilize time-of-flight techniques with a pulsed neutron beam and detection of the two emitted neutrons in coincidence. A description of our initial measurements at 10 MeV for a single scattering angle will be presented along with preliminary results. Also, plans for measurements at other energies with broad angular coverage will be discussed.

  3. Neutron data library for transactinides at energies up to 100 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Korovin, Y.A.; Artisyuk, V.V.; Konobeyev, A.Y. [Obninsk Institute of Nuclear Power Engineering (Russian Federation)

    1995-10-01

    New neutron data library for transactinides is briefly described. The library includes evaluated cross-sections for fission and threshold neutron induced reactions for isotopes of U, Np and Pu at energies 0-100 MeV.

  4. Neutrons leaked from a 45 MeV linac facility

    Energy Technology Data Exchange (ETDEWEB)

    Kitaichi, Masatoshi; Sawamura, Sadashi; Yamada, Takuma; Sawamura, Teruko; Kaneko, Junnichi H. [Hokkaido Univ., Sapporo (Japan); Nojiri, Itiro [Japan Nuclear Cycle Development Institute, Ibaraki (Japan)

    2002-07-01

    Dose evaluation for skyshine from nuclear facilities is an issue in environmental evaluations. Therefore, benchmark data for skyshine and well-investigated codes for skyshine would be useful in the rational evaluations of nuclear facilities. The purpose of this study is to obtain benchmark data of skyshine and to investigate the effect of source spectra and angular distribution on the skyshine process. In this study spatial and time distributions of neutrons leaked from the Hokkaido University 45 MeV electron linac facility were measured and compared with calculations. Neutrons were emitted from the ( ,n) reaction produced by bremsstrahlung radiation in a lead target irradiated with electrons from the linac. The skyshine process of neutrons transported through the facility building to the outside was investigated. The source spectrum of the skyshine process was evaluated using a cylindrical multi-moderator spectrometer and unfolding code, the SAND-II, and the results were compared. Measurements were carried out to a distance of 330 m from the facility. The measured spatial dose distribution was found not to coincide with the calculations. The discrepancy is discussed based on an analysis of the spatial and time distributions, and the energy spectrum which suggests that the source spectrum and the angular distribution assumed in the calculation was not sufficiently similar to simulate the experimental situation. The time distribution introduced in this study appears to be useful in discussions of the skyshine process and its sources.

  5. Recent advances in fast neutron radiography for cargo inspection

    International Nuclear Information System (INIS)

    Sowerby, B.D.; Tickner, J.R.

    2007-01-01

    Fast neutron radiography techniques are attractive for screening cargo for contraband such as narcotics and explosives. Neutrons have the required penetration, they interact with matter in a manner complementary to X-rays and they can be used to determine elemental composition. Compared to neutron interrogation techniques that measure secondary radiation (neutron or gamma-rays), neutron radiography systems are much more efficient and rapid and they are much more amenable to imaging. However, for neutron techniques to be successfully applied to cargo screening, they must demonstrate significant advantages over well-established X-ray techniques. This paper reviews recent developments and applications of fast neutron radiography for cargo inspection. These developments include a fast neutron and gamma-ray radiography system that utilizes a 14 MeV neutron generator as well as fast neutron resonance radiography systems that use variable energy quasi-monoenergetic neutrons and pulsed broad energy neutron beams. These systems will be discussed and compared with particular emphasis on user requirements, sources, detector systems, imaging ability and performance

  6. Development of neutron-monitor detectors applicable for energies up to 100 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Sato, Tatsuhiko; Endo, Akira; Yamaguchi, Yasuhiro; Kim, Eunjoo [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment; Nakamura, Takashi [Tohoku Univ., Sendai, Miyagi (Japan)

    2003-03-01

    For the purpose of monitoring of neutron doses in high energy accelerator facilities, we have been developing neutron detectors which are applicable for neutron energies up to 100 MeV. The present paper reports characteristics of a phoswitch-type neutron detector which is composed of a liquid organic scintillator and {sup 6}Li+ZnS(Ag) sheets. (author)

  7. Calculation of 14 MeV neutron transmission

    International Nuclear Information System (INIS)

    Vyrskij, M.Yu.; Dubinin, A.A.; Zhuravlev, V.I.; Isaev, N.V.; Klintsov, A.A.; Krivtsov, A.S.; Linge, I.I.; Panfilov, E.I.; Prit'mov, A.P.

    1979-01-01

    The possibility of using the 28 group constant system (28-GCS) for calculating the transport of neutrons with initial energy of 14 MeV in thermonuclear reactor blankets is studied. A blanket project suggested by the Oak Ridge National Laboratory is used as a test version to estimate applicability of the 28-GCS. Niobium is used in a blanket as a structural material. A mixture of lithium nuclides is used for tritium production. The results of blanket test calculation and the calculational results obtained using the 28-GCS from the UKNDL library are compared. The numerical 28-group calculation of blonket is carried out by means of the ROZ-6 and ROZ-9 codes but not by the Monte-Carlo method as compared with the test calculation. Time of the blanket calculation on the BESM-6 computer by means of the ROZ-9 code in 2P 5 approximation using the 28-GCS amounts to 10 min. It is noted that to create effective codes for the numerical blanket calculation different calculational grids are necessary for different energy grups. The calculations carried out have shown the possibility of using the 28-group library of cross sections for the numerical solution of the neutron transport equation in estimating analysis of blankets

  8. Review of RBE values of 15 MeV neutrons for effects on normal tissues

    NARCIS (Netherlands)

    Broerse, J.J.

    1974-01-01

    Values of the relative biological effectiveness (RBE) of fast neutrons for effect on normal tissue depend not only on the neutron energy and the dose, but also on the type of tissue irradiated. Values of the RBE of 15 MeV neutrons are reviewed for rapidly proliferating rodent tissue, such as mouse

  9. The neutron-deuteron elastic scattering angular distribution at 95 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Mermod, Philippe

    2004-04-01

    The neutron-deuteron elastic scattering differential cross section has been measured at 95 MeV incident neutron energy, with the Medley setup at TSL in Uppsala. The neutron-proton differential cross section has also been measured for normalization purposes. The data are compared with theoretical calculations to investigate the role of three-nucleon force effects.

  10. Neutron scattering differential cross sections of carbon and bismuth at 37 MeV

    International Nuclear Information System (INIS)

    Zhou Zuying; Tang Hongqing; Qi Bujia; Zhou Chenwei; Du Yanfeng; Xia Haihong; Walter, R.L.; Tornow, W.; Howell, C.; Braun, R.; Roper, C.; Chen Zemin; Chen Zhengpeng; Chen Yingtang

    1997-01-01

    Elastic differential cross sections of 37 MeV neutrons scattered from carbon and bismuth were measured in the angular range 11 to 160 degrees by means of the multi-detector TOF facility. The 37 MeV neutrons were produced via the T(d,n) 4 He reaction in a tritium gas target. The pulsed 20 MeV deuteron beam was provided by the HI-13 tandem accelerator. The angular distribution of scattered neutrons from carbon and bismuth were measured in the angular range 11 degree to 145 degree and 11 degree to 160 degree respectively in steps of about 3 degree

  11. Measurement of neutron captured cross-sections in 1-2 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Gi Dong; Kim, Young Sek; Kim, Jun Kon; Yang, Tae Keun [Korea Institutes of Geoscience and Mineral Resources, Taejeon (Korea)

    2001-04-01

    The measurement of neutron captured reaction cross sections was performed to build the infra system for the production of nuclear data. MeV neutrons were produced with TiT target and {sup 3}T(p,n){sup 3}He reaction. The characteristics of TiT thin film was analyzed with ERD-TOF and RBS. The results was published at Journal of the Korea Physical Society (SCI registration). The energy, the energy spread and the flux of the produced neutron were measured. The neutron excitation functions of {sup 12}C and {sup 16}O were obtained to confirm the neutron energy and neutron energy spread. The neutron energy spread found to be 1.3 % at the neutron energy of 2.077 MeV. The {sup 197}Au(n,{gamma}) reaction was performed to obtain the nerutron flux. The maximum neutron flux found to be 1 x 10{sup 8} neutrons/sec at the neutron energy of 2 MeV. The absolute efficiency of liquid scintillation detector was obtained in the neutron energy of 1 - 2 MeV. The fast neutron total reaction cross sections of Cu, Fe, and Au were measured with sample in-out method. Also the neutron captured reaction cross sections of {sup 63}Cu were measured with fast neutron activation method. The measurement of neutron total reaction cross sections and the neutron captured reaction cross sections with fast neutrons were first tried in Korea. The beam pulsing system was investigated and the code of calculating the deposition spectrums for primary gamma rays was made to have little errors at nuclear data. 25 refs., 28 figs., 14 tabs. (Author)

  12. Neutron-photon multigroup cross sections for neutron energies less than or equal to400 MeV. Revision 1

    International Nuclear Information System (INIS)

    Alsmiller, R.G. Jr.; Barnes, J.M.; Drischler, J.D.

    1986-01-01

    For a variety of applications, e.g., accelerator shielding design, neutrons in radiotherapy, radiation damage studies, etc., it is necessary to carry out transport calculations involving medium-energy (greater than or equal to20 MeV) neutrons. A previous paper described neutron-photon multigroup cross sections in the ANISN format for neutrons from thermal to 400 MeV. In the present paper the cross-section data presented previously have been revised to make them agree with available experimental data. 7 refs., 1 fig

  13. Neutron-induced reactions on U and Th - A new approach via AMS

    International Nuclear Information System (INIS)

    Wallner, A.; Capote, R.; Christl, M.; Fifield, L.K.; Srncik, M.; Tims, S.; Hotchkis, M.; Krasa, A.; Lachner, J.; Lippold, J.; Plompen, A.; Semkova, V.; Steier, P.; Winkler, S.

    2014-01-01

    Recent studies exhibit discrepancies at keV and MeV energies between major nuclear data libraries for 238 U(n,γ), 232 Th(n,γ) and also for (n,xn) reactions. We have extended our initial (n,γ) measurements on 235,238 U to higher neutron energies and to additional reaction channels. Neutron-induced reactions on 232 Th and 238 U were measured by a combination of the activation technique and atom counting of the reaction products using accelerator mass spectrometry (AMS). Natural thorium and uranium samples were activated with quasi-monoenergetic neutrons at IRMM. Neutron capture data were produced for neutron energies between 0.5 and 5 MeV. Fast neutron-induced reactions were studied in the energy range from 17 to 22 MeV. Preliminary data indicate a fair agreement with data libraries; however at the lower band of existing data. This approach represents a complementary method to on-line particle detection techniques and also to conventional decay counting. (authors)

  14. Isomeric cross sections of neutron induced reactions on Ge and Ir isotopes

    International Nuclear Information System (INIS)

    Vlastou, R.; Papadopoulos, C.T.; Kokkoris, M.; Perdikakis, G.; Galanopoulos, S.; Patronis, N.; Serris, M.; Perdikakis, G.; Harissopulos, S.; Demetriou, P.

    2008-01-01

    The 72 Ge(n,α) 69m Zn, 74 Ge(n,α) 71m Zn, 76 Ge(n,2n) 75g+m Ge and 191 Ir(n,2n) 190 Ir g+m1 and 191 Ir(n,2n) 190 Ir m2 reaction cross sections were measured from 9.6 to 11.4 MeV relative to the 27 Al(n,α) 24 Na reference reaction via the activation method. The quasi-monoenergetic neutron beams were produced via the 2 H(d,n) 3 He reaction at the 5 MV VdG Tandem T11/25 accelerator of NCSR 'Demokritos'. Statistical model calculations using the codes STAPRE-F and EMPIRE (version 2.19) and taking into account pre-equilibrium emission were performed on the data measured in this work as well as on data reported in literature. (authors)

  15. Measurement of neutron yield by 62 MeV proton beam on a thick beryllium target

    Energy Technology Data Exchange (ETDEWEB)

    Osipenko, M., E-mail: osipenko@ge.infn.it [INFN, sezione di Genova, 16146 Genova (Italy); Ripani, M. [INFN, sezione di Genova, 16146 Genova (Italy); Alba, R. [INFN, Laboratori Nazionali del Sud, 95123 Catania (Italy); Ricco, G. [INFN, sezione di Genova, 16146 Genova (Italy); Schillaci, M. [INFN, Laboratori Nazionali del Sud, 95123 Catania (Italy); Barbagallo, M. [INFN, sezione di Bari, 70126 Bari (Italy); Boccaccio, P. [INFN, Laboratori Nazionali di Legnaro, 35020 Legnaro (Italy); Celentano, A. [Dipartimento di Fisica dell' Università di Genova, 16146 Genova (Italy); Colonna, N. [INFN, sezione di Bari, 70126 Bari (Italy); Cosentino, L.; Del Zoppo, A.; Di Pietro, A. [INFN, Laboratori Nazionali del Sud, 95123 Catania (Italy); Esposito, J. [INFN, Laboratori Nazionali di Legnaro, 35020 Legnaro (Italy); Figuera, P.; Finocchiaro, P. [INFN, Laboratori Nazionali del Sud, 95123 Catania (Italy); Kostyukov, A. [Moscow State University, Moscow 119992 (Russian Federation); Maiolino, C.; Santonocito, D.; Scuderi, V. [INFN, Laboratori Nazionali del Sud, 95123 Catania (Italy); Viberti, C.M. [Dipartimento di Fisica dell' Università di Genova, 16146 Genova (Italy)

    2013-09-21

    The design of a low-power prototype of neutron amplifier recently proposed within the INFN-E project indicated the need for more accurate data on the neutron yield produced by a proton beam with energy of about 70 MeV impinging on a thick beryllium target. Such measurement was performed at the LNS superconducting cyclotron, covering a wide angular range from 0° to 150° and a complete neutron energy interval from thermal to beam energy. Neutrons with energy above 0.5 MeV were measured by liquid scintillators exploiting their time of flight to determine the kinetic energy. For lower energy neutrons, down to thermal energy, a {sup 3}He detector was used. The obtained data are in good agreement with previous measurements at 0° using 66 MeV proton beam, covering neutron energies >10MeV, as well as with measurements at few selected angles using protons of 46, 55 and 113 MeV energy. The present results extend the neutron yield data in the 60–70 MeV beam energy range. A comparison of measured yields to MCNP, FLUKA and Geant4 Monte Carlo simulations was performed.

  16. Transport calculations for a 14.8 MeV neutron beam in a water phantom

    International Nuclear Information System (INIS)

    Goetsch, S.J.

    1981-01-01

    A coupled neutron/photon Monte Carlo radiation transport code (MORSE-CG) has been used to calculate neutron and photon doses in a water phantom irradiated by 14.8 MeV neutrons from the Gas Target Neutron Source. The source-collimator-phantom geometry was carefully simulated. Results of calculations utilizing two different statistical estimators (next-collision and track-length) are presented

  17. Neutron-induced charged-particle emission studies below 100 MeV at WNR

    Energy Technology Data Exchange (ETDEWEB)

    Haight, R.C.; Lee, T.M.; Sterbenz, S.M. [and others

    1994-07-01

    Charged-particles produced by neutron bombardment of selected targets with Z=5 through 53 have been studied for neutron energies from 1 MeV to about 100 MeV using the spallation neutron source at WNR/LAMPF. Particle detection with energy measurement and particle identification is accomplished by two-element {Delta}E-E counters, three-element {Delta}E{sub l}-{Delta}E{sub 2}-E counters or with pulse-shape discrimination using scintillators directly in the neutron beam. The experimental techniques for these measurements are described and comparisons made among the different approaches. This presentation introduces five papers contributed to this conference.

  18. Neutron-induced charged-particle emission studies below 100 MeV at WNR

    International Nuclear Information System (INIS)

    Haight, R.C.; Lee, T.M.; Sterbenz, S.M.

    1994-01-01

    Charged-particles produced by neutron bombardment of selected targets with Z=5 through 53 have been studied for neutron energies from 1 MeV to about 100 MeV using the spallation neutron source at WNR/LAMPF. Particle detection with energy measurement and particle identification is accomplished by two-element ΔE-E counters, three-element ΔE l -ΔE 2 -E counters or with pulse-shape discrimination using scintillators directly in the neutron beam. The experimental techniques for these measurements are described and comparisons made among the different approaches. This presentation introduces five papers contributed to this conference

  19. Secondary neutron double differential cross sections from 209Bi at 14.2 MeV

    International Nuclear Information System (INIS)

    Shen Guanren; Xia Haihong; Tang Hongqing

    1992-01-01

    The secondary neutron double differential cross sections from 209 Bi at 14.2 MeV have been measured at 6 angles between 25 degree-150 degree using an associated particle TOF spectrometer. Flight path was 2.7 m. The neutron detector was biased at 1.3 MeV. The time resolution was about 1.2 ns. The data were compared with existing data and theoretical calculated results. Good agreement is achieved

  20. High energy resolution characteristics on 14MeV neutron spectrometer for fusion experimental reactor

    Energy Technology Data Exchange (ETDEWEB)

    Iguchi, Tetsuo [Tokyo Univ., Tokai, Ibaraki (Japan). Nuclear Engineering Research Lab.; Takada, Eiji; Nakazawa, Masaharu

    1996-10-01

    A 14MeV neutron spectrometer suitable for an ITER-like fusion experimental reactor is now under development on the basis of a recoil proton counter telescope principle in oblique scattering geometry. To verify its high energy resolution characteristics, preliminary experiments are made for a prototypical detector system. The comparison results show reasonably good agreement and demonstrate the possibility of energy resolution of 2.5% in full width at half maximum for 14MeV neutron spectrometry. (author)

  1. The development of a spectrometer for 14 MeV neutrons from fusion

    International Nuclear Information System (INIS)

    Aronsson, D.

    1991-01-01

    A spectrometer for 14 MeV neutrons, to be used for fusion plasma diagnostics at JET, was developed. The spectrometer utilizes neutron scattering in a polyethylene foil with the detection of the scattered neutron and its associated recoil proton. For the detection of 12 MeV protons we have tested silicon surface barrier detectors, lithium-drifted silicon detectors and high purity germanium detectors. The lithium-drifted detectors were finally selected for use in the spectrometer. The lithium-drifted silicon diodes have also been used for direct spectrometry, utilizing the neutron induced charged particle reactions in silicon. The methods used for the energy calibration and the timing calibration of the diodes, both during the installation of the spectrometer and during operation, are described. The detection of 2 MeV neutrons is done by fast plastic scintillators. Since the neutron generator which was used to test the detectors supplies 14 MeV or 2.5 MeV neutrons only, a neutron energy converter has to be constructed to study the detectors at other neutron energies. In the actual spectrometer an array of scintillation neutron detectors is used. A method of calibrating such an array of detectors with a gamma source was elaborated and is also described here. The result of the calibration is a set of parameters than can be used to determine the high voltage settings and the discriminator levels that are needed to achieve homogeneous sensitivity for all the detectors of the array. The energy scale itself was then calibrated by using gamma sources of various energies. To test the spectrometer as a whole at a neutron generator, a test bed was constructed. A lithium-drifted silicon diode was used to measure the neutron flux and the neutron energy resolution in the test bed. (au)

  2. Measurements of prompt gamma-rays from fast-neutron induced fission with the LICORNE directional neutron source

    CERN Document Server

    Wilson, J N; Halipre, P; Oberstedt, S; Oberstedt, A

    2014-01-01

    At the IPN Orsay we have developed a unique, directional, fast neutron source called LICORNE, intended initially to facilitate prompt fission gamma measurements. The ability of the IPN Orsay tandem accelerator to produce intense beams of $^7$Li is exploited to produce quasi-monoenergetic neutrons between 0.5 - 4 MeV using the p($^7$Li,$^7$Be)n inverse reaction. The available fluxes of up to 7 × 10$^7$ neutrons/second/steradian for the thickest hydrogen-rich targets are comparable to similar installations, but with two added advantages: (i) The kinematic focusing produces a natural neutron beam collimation which allows placement of gamma detectors adjacent to the irradiated sample unimpeded by source neutrons. (ii) The background of scattered neutrons in the experimental hall is drastically reduced. The dedicated neutron converter was commissioned in June 2013. Some preliminary results from the first experiment using the LICORNE neutron source at the IPN Orsay are presented. Prompt fission gamma rays from fas...

  3. A possible approach to 14MeV neutron moderation: A preliminary study case.

    Science.gov (United States)

    Flammini, D; Pilotti, R; Pietropaolo, A

    2017-07-01

    Deuterium-Tritium (D-T) interactions produce almost monochromatic neutrons with about 14MeV energy. These neutrons are used in benchmark experiments as well as for neutron cross sections assessment in fusion reactors technology. The possibility to moderate 14MeV neutrons for purposes beyond fusion is worth to be studied in relation to projects of intense D-T sources. In this preliminary study, carried out using the MCNP Monte Carlo code, the moderation of 14MeV neutrons is approached foreseeing the use of combination of metallic materials as pre-moderator and reflectors coupled to standard water moderators. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Table of nuclear reactions and subsequent radioactive dacays induced by 14-MeV neutrons

    International Nuclear Information System (INIS)

    Tsukada, Kineo

    1977-09-01

    Compilation of the data on nuclear reactions and subsequent radioactive decays induced by 14-MeV neutrons is presented in tabular form for most of the isotopes available in nature and for some of the artificially-produced isotopes, including the following items: Nuclide (isotopic abundance), type of nuclear reaction, reaction Q-value, reaction product, type of decay, decay Q-value, half-life of reaction product, decay product, maximum reaction cross section, neutron energy for maximum cross section, reaction cross section for 14 MeV neutrons, saturated radioactivity induced by irradiation of a neutron flux of 1 n/cm 2 sec for a mol of atoms, and reference for the cross section. The mass number dependence of (n, γ), (n, 2n), (n, p), (n, d), (n, t), (n, 3 He) and (n, α) reaction cross sections for 14-MeV neutrons is given in figures to show general trends of the cross sections

  5. Actinide neutron-induced fission up to 20 MeV

    International Nuclear Information System (INIS)

    Maslov, V.M.

    2001-01-01

    Fission and total level densities modelling along with double-humped fission barrier parameters allow to describe available actinide neutron-induced fission cross section data in the incident neutron energy range of ∼ 10 keV - 20 MeV. Saddle asymmetries relevant to shell correction model calculations influence fission barriers, extracted by cross section data analysis. The inner barrier was assumed axially symmetric in case of U, Np and Pu neutron-deficient nuclei. It is shown that observed irregularities in neutron-induced fission cross section data in the energy range of 0.5-3 MeV could be attributed to the interplay of few-quasiparticle excitations in the level density of fissioning and residual nuclei. Estimates of first-chance fission cross section and secondary neutron spectrum model were validated by 238 U fission, (n,2n) and (n,3n) data description up to 20 MeV. (author)

  6. Actinide neutron-induced fission up to 20 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Maslov, V M [Radiation Physics and Chemistry Problems Institute, Minsk-Sosny (Belarus)

    2001-12-15

    Fission and total level densities modelling along with double-humped fission barrier parameters allow to describe available actinide neutron-induced fission cross section data in the incident neutron energy range of {approx} 10 keV - 20 MeV. Saddle asymmetries relevant to shell correction model calculations influence fission barriers, extracted by cross section data analysis. The inner barrier was assumed axially symmetric in case of U, Np and Pu neutron-deficient nuclei. It is shown that observed irregularities in neutron-induced fission cross section data in the energy range of 0.5-3 MeV could be attributed to the interplay of few-quasiparticle excitations in the level density of fissioning and residual nuclei. Estimates of first-chance fission cross section and secondary neutron spectrum model were validated by {sup 238}U fission, (n,2n) and (n,3n) data description up to 20 MeV. (author)

  7. Calibration Of A 14 MeV Neutron Generator With Reference To NBS-1

    International Nuclear Information System (INIS)

    Heimbach, Craig R.

    2011-01-01

    NBS-1 is the US national neutron reference source. It has a neutron emission rate (June 1961) of 1.257x10 6 n/s 1,2,3 with an uncertainty of 0.85%(k = 1). Neutron emission-rate calibrations performed at the National Institute of Standards and Technology (NIST) are made in comparison to this source, either directly or indirectly. To calibrate a commercial 14 MeV neutron generator, NIST performed a set of comparison measurements to evaluate the neutron output relative to NBS-1. The neutron output of the generator was determined with an uncertainty of about 7%(k = 1). The 15-hour half-life of one of the reactions used also makes possible off-site measurements. Consideration is given to similar calibrations for a 2.5 MeV neutron generator.

  8. Neutron-photon multigroup cross sections for neutron energies up to 400 MeV: HILO86R

    International Nuclear Information System (INIS)

    Kotegawa, Hiroshi; Nakane, Yoshihiro; Hasegawa, Akira; Tanaka, Shun-ichi

    1993-02-01

    A macroscopic multigroup cross section library of 66 neutron and 22 photon groups for neutron energies up to 400 MeV: HILO86R is prepared for 10 typical shielding materials; water, concrete, iron, air, graphite, polyethylene, heavy concrete, lead, aluminum and soil. The library is a revision of the DLC-119/HILO86, in which only the cross sections below 19.6 MeV have been exchanged with a group cross section processed from the JENDL-3 microscopic cross section library. In the HILO86R library, self shielding factors are used to produce effective cross sections for neutrons less than 19.6 MeV considering rather coarse energy meshes. Energy spectra and dose attenuation in water, concrete and iron have been compared among the HILO, HILO86 and HILO86R libraries for different energy neutron sources. Significant discrepancy has been observed in the energy spectra less than a couple of MeV energy in iron among the libraries, resulting large difference in the dose attenuation. The difference was attributed to the effect of self-shielding factor, namely to the difference between infinite dilution and effective cross sections. Even for 400 MeV neutron source the influence of the self-shielding factor is significant, nevertheless only the cross sections below 19.6 MeV are exchanged. (author)

  9. Measured neutron carbon kerma factors from 14.1 MeV to 18 MeV

    International Nuclear Information System (INIS)

    Deluca, P.M.; Barschall, H.H.; McDonald, J.C.

    1985-01-01

    For A-150 tissue-equivalent plastic, the total neutron kerma is dominated by the hydrogen kerma. Tissue kerma is inferred with reasonable accuracy by normalization to the kerma factor ratio between tissue and A-150 plastic. Because of the close match in the hydrogen abundance in these materials, the principal uncertainty is due to the kerma factors of carbon and oxygen. We have measured carbon kerma factor values of 0.183+-0.015 10 -8 cGy cm 2 and 0.210+-0.016 10 -8 cGy cm 2 at 14.1-MeV and 15-MeV neutron energy, respectively. A preliminary value of 0.297+-0.03 10 -8 cGy cm 2 has been determined at 17.9 MeV. A recent microscopic cross section measurement of the (n,n'3α) reaction in carbon at 14.1-MeV energy gives a kerma factor of 0.184+-0.019 10 -8 cGy cm 2 in agreement with the present result

  10. Measured neutron carbon kerma factors from 14.1 MeV to 18 MeV

    International Nuclear Information System (INIS)

    Deluca, P.M. Jr.; Barschall, H.H.; Haight, R.C.; McDonald, J.C.

    1984-01-01

    For A-150 tissue-equivalent plastic, the total neutron kerma is dominated by the hydrogen kerma. Tissue kerma is inferred with reasonable accuracy by normalization to the kerma factor ratio between tissue and A-150 plastic. Because of the close match in the hydrogen abundance in these materials, the principal uncertainty is due to the kerma factors of carbon and oxygen. We have measured carbon kerma factor values of 0.183 +- 0.015 10 -8 cGy cm 2 and 0.210 +- 0.16 10 -8 cGy cm 2 at 14.1-MeV and 15-MeV neutron energy, respectively. A preliminary value of 0.297 +- 0.03 10 -8 cGy cm 2 has been determined at 17.9 MeV. A recent microscopic cross section measurement of the (n,n'3α) reaction in carbon at 14.1-MeV energy gives a kerma factor of 0.184 +- 0.019 10 8 cGy cm 2 in agreement with the present result. 9 refs., 4 figs., 2 tabs

  11. Neutron leakage spectra from Be, Pb and U spheres at 14 MeV energy

    International Nuclear Information System (INIS)

    Androsenko, A.A.; Androsenko, P.A.; Devkin, B.V.

    1989-01-01

    Experimental data on neutron leakage spectra from beryllium, lead and uranium spheres with a central 14 MeV neutron source using a time-of-flight spectrometer have been measured. The data were compared with those calculated with the BLANK code using different nuclear data files. 15 refs, 1 fig., 2 tabs

  12. Neutron-induced fission cross sections of uraniums up to 40 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Maslov, V.M. [Radiation Physics and Chemistry Problems Inst., Minsk-Sosny (Belarus); Hasegawa, A.

    1998-11-01

    Statistical theory of nuclear reactions, well-proved below 20 MeV, is applied for {sup 235}U and {sup 238}U fission data analysis up to {approx}40 MeV. It is shown that measured data could be reproduced. Chance structure of measured fission cross section is provided, it`s validity is supported by description of data for competing (n,xn)-reactions. Role of fissility of target nucleus is addressed. It seems that gap in incident neutron energy interval of 20 MeV - 50 MeV, below which evaluation approaches are well-developed, and above which simplified statistical approaches are valid, could be covered. (author)

  13. EXPERIMENTAL ANALYSES OF SPALLATION NEUTRONS GENERATED BY 100 MEV PROTONS AT THE KYOTO UNIVERSITY CRITICAL ASSEMBLY

    Directory of Open Access Journals (Sweden)

    CHEOL HO PYEON

    2013-02-01

    Full Text Available Neutron spectrum analyses of spallation neutrons are conducted in the accelerator-driven system (ADS facility at the Kyoto University Critical Assembly (KUCA. High-energy protons (100 MeV obtained from the fixed field alternating gradient accelerator are injected onto a tungsten target, whereby the spallation neutrons are generated. For neutronic characteristics of spallation neutrons, the reaction rates and the continuous energy distribution of spallation neutrons are measured by the foil activation method and by an organic liquid scintillator, respectively. Numerical calculations are executed by MCNPX with JENDL/HE-2007 and ENDF/B-VI libraries to evaluate the reaction rates of activation foils (bismuth and indium set at the target and the continuous energy distribution of spallation neutrons set in front of the target. For the reaction rates by the foil activation method, the C/E values between the experiments and the calculations are found around a relative difference of 10%, except for some reactions. For continuous energy distribution by the organic liquid scintillator, the spallation neutrons are observed up to 45 MeV. From these results, the neutron spectrum information on the spallation neutrons generated at the target are attained successfully in injecting 100 MeV protons onto the tungsten target.

  14. Control of quasi-monoenergetic electron beams from laser-plasma accelerators with adjustable shock density profile

    Science.gov (United States)

    Tsai, Hai-En; Swanson, Kelly K.; Barber, Sam K.; Lehe, Remi; Mao, Hann-Shin; Mittelberger, Daniel E.; Steinke, Sven; Nakamura, Kei; van Tilborg, Jeroen; Schroeder, Carl; Esarey, Eric; Geddes, Cameron G. R.; Leemans, Wim

    2018-04-01

    The injection physics in a shock-induced density down-ramp injector was characterized, demonstrating precise control of a laser-plasma accelerator (LPA). Using a jet-blade assembly, experiments systematically varied the shock injector profile, including shock angle, shock position, up-ramp width, and acceleration length. Our work demonstrates that beam energy, energy spread, and pointing can be controlled by adjusting these parameters. As a result, an electron beam that was highly tunable from 25 to 300 MeV with 8% energy spread (ΔEFWHM/E), 1.5 mrad divergence, and 0.35 mrad pointing fluctuation was produced. Particle-in-cell simulation characterized how variation in the shock angle and up-ramp width impacted the injection process. This highly controllable LPA represents a suitable, compact electron beam source for LPA applications such as Thomson sources and free-electron lasers.

  15. Elastic Neutron Scattering at 96 MeV from {sup 12}C and {sup 208}Pb

    Energy Technology Data Exchange (ETDEWEB)

    Klug, J.; Blomgren, J.; Atac, A. [and others

    2003-04-01

    A facility for detection of scattered neutrons in the energy interval 50-130 MeV, SCANDAL (SCAttered Nucleon Detection AssembLy), has recently been installed at the 20-180 MeV neutron beam line of the The Svedberg Laboratory, Uppsala. Elastic neutron scattering from {sup 12}C and {sup 208}Pb has been studied at 96 MeV in the 10-70 deg interval. The achieved energy resolution, 3.7 MeV, is about an order of magnitude better than for any previous experiment above 65 MeV incident energy. The present experiment represents the highest neutron energy where the ground state has been resolved from the first excited state in neutron scattering. A novel method for normalization of the absolute scale of the cross section has been used. The estimated uncertainty, 3 %, is unprecedented for a neutron-induced differential cross section measurement on a nuclear target. The results are compared with modern optical model predictions, based on phenomenology or microscopic nuclear theory.

  16. Neutron response matrix for unfolding NE-213 measurements to 21 MeV

    International Nuclear Information System (INIS)

    Ingersoll, D.T.; Wehring, B.W.; Johnson, R.H.

    1976-01-01

    A neutron response matrix from measured neutron responses of NE-213 in the energy range of 0.2 to 22 MeV is presented. An interpolation scheme was used to construct an 81-column matrix from the data of Verbinski, Burrus, Love, Zobel, and Hill. As a test of the new response matrix, the Cf-252 neutron spectrum was measured and unfolded using the new response matrix and the FORIST unfolding code. The spectrum agrees well with previous measurements at lower energies, while providing new information above 8 MeV

  17. 14 MeV calibration of JET neutron detectors—phase 1: calibration and characterization of the neutron source

    Science.gov (United States)

    Batistoni, P.; Popovichev, S.; Cufar, A.; Ghani, Z.; Giacomelli, L.; Jednorog, S.; Klix, A.; Lilley, S.; Laszynska, E.; Loreti, S.; Packer, L.; Peacock, A.; Pillon, M.; Price, R.; Rebai, M.; Rigamonti, D.; Roberts, N.; Tardocchi, M.; Thomas, D.; Contributors, JET

    2018-02-01

    In view of the planned DT operations at JET, a calibration of the JET neutron monitors at 14 MeV neutron energy is needed using a 14 MeV neutron generator deployed inside the vacuum vessel by the JET remote handling system. The target accuracy of this calibration is  ±10% as also required by ITER, where a precise neutron yield measurement is important, e.g. for tritium accountancy. To achieve this accuracy, the 14 MeV neutron generator selected as the calibration source has been fully characterised and calibrated prior to the in-vessel calibration of the JET monitors. This paper describes the measurements performed using different types of neutron detectors, spectrometers, calibrated long counters and activation foils which allowed us to obtain the neutron emission rate and the anisotropy of the neutron generator, i.e. the neutron flux and energy spectrum dependence on emission angle, and to derive the absolute emission rate in 4π sr. The use of high resolution diamond spectrometers made it possible to resolve the complex features of the neutron energy spectra resulting from the mixed D/T beam ions reacting with the D/T nuclei present in the neutron generator target. As the neutron generator is not a stable neutron source, several monitoring detectors were attached to it by means of an ad hoc mechanical structure to continuously monitor the neutron emission rate during the in-vessel calibration. These monitoring detectors, two diamond diodes and activation foils, have been calibrated in terms of neutrons/counts within  ±5% total uncertainty. A neutron source routine has been developed, able to produce the neutron spectra resulting from all possible reactions occurring with the D/T ions in the beam impinging on the Ti D/T target. The neutron energy spectra calculated by combining the source routine with a MCNP model of the neutron generator have been validated by the measurements. These numerical tools will be key in analysing the results from the in

  18. Neutron-induced 2.2 MeV background in gamma ray telescopes

    International Nuclear Information System (INIS)

    Zanrosso, E.M.; Long, J.L.; Zych, A.D.; White, R.S.; Hughes Aircraft Co., Los Angeles, CA)

    1985-01-01

    Neutron-induced gamma ray production is an important source of background in Compton scatter gamma ray telescopes where organic scintillator material is used. Most important is deuteron formation when atmospheric albedo and locally produced neutrons are thermalized and subsequently absorbed in the hydrogenous material. The resulting 2.2 MeV gamma line essentially represents a continuous isotropic source within the scintillator itself. Interestingly, using a scintillator material with a high hydrogen-to-carbon ratio to minimize the neutron-induced 4.4 MeV carbon line favors the np reaction. The full problem of neutron-induced background in Compton scatter telescopes has been previously discussed. Results are presented of observations with the University of California balloon-borne Compton scatter telescope where the 2.2 MeV induced line emission is prominently seen

  19. Survival of parenchymal hepatocytes exposed to 14.3-MeV neutrons

    International Nuclear Information System (INIS)

    Jirtle, R.L.; Gould, M.N.; DeLuca, P.M. Jr.; Pearson, D.W.

    1982-01-01

    This report presents the results of the measurement of a dose survival curve and RBE values for rat hepatic cells irradiated in vivo with 14.3 MeV neutrons. The purpose was to determine the RBE for neutrons as a function of dose, and whether hepatocytes exposed to neutrons are as efficient at repairing potentially lethal damage as they are after exposure to low LET radiation

  20. Measurement of neutron yield by 62 MeV proton beam on a thick Beryllium target

    International Nuclear Information System (INIS)

    Alba, R; Cosentino, G; Zoppo, A Del; Pietro, A Di; Figuera, P; Finocchiaro, P; Maiolino, C; Santonocito, D; Schillaci, M; Barbagallo, M; Colonna, N; Boccaccio, P; Esposito, J; Celentano, A; Osipenko, M; Ricco, G; Ripani, M; Viberti, C M; Kostyukov, A

    2013-01-01

    In the framework of research on IVth generation reactors and high intensity neutron sources a low-power prototype neutron amplifier was recently proposed by INFN. It is based on a low-energy, high current proton cyclotron, whose beam, impinging on a thick Beryllium converter, produces a fast neutron spectrum. The world database on the neutron yield from thick Beryllium target in the 70 MeV proton energy domain is rather scarce. The new measurement was performed at LNS, covering a wide angular range from 0 to 150 degrees and an almost complete neutron energy interval. In this contribution the preliminary data are discussed together with the proposed ADS facility.

  1. Preliminary design of GDT-based 14 MeV neutron source

    International Nuclear Information System (INIS)

    Du Hongfei; Chen Dehong; Wang Hui; Wang Fuqiong; Jiang Jieqiong; Wu Yican; Chen Yiping

    2012-01-01

    To meet the need of D-T fusion neutron source for fusion material testing, design goals were presented in this paper according to the international requirements of neutron source for fusion material testing. A preliminary design scheme of GDT-based 14 MeV neutron source was proposed, and a physics model of the neutron source was built based on progress of GDT experiments. Two preliminary design schemes (i. e. FDS-GDT1, FDS-GDT2) were designed; among which FDS-GDT2 can be used for fusion material testing with neutron first wall loading of 2 MW/m 2 . (authors)

  2. Neutron emission in fission of highly excited californium nuclei (E*=76 MeV)

    International Nuclear Information System (INIS)

    Blinov, M.V.; Bordyug, V.M.; Kozulin, Eh.M.; Mozhaev, A.N.; Levitovich, M.; Muzychka, Yu.A.; Penionzhkevich, Yu.Eh.; Pustyl'nik, B.I.

    1990-01-01

    The differential cross sections for neutron production in the fission of highly excited californium nuclei formed in the 238 U+ 12 C (105 MeV) reaction have been measured. From the analysis of the experimental data is follows that the number of pre-fission neutrons substantially exceeds the value obtained in the framework of the standard statistical model. The saddle-to-scission time of the excited nucleus is estimated on the basis of the neutron multiplicity. The dependences of the neutron number and neutron average energies upon the fragment mass are determined

  3. The polarization of MeV neutrons elastically scattered from 4He

    International Nuclear Information System (INIS)

    Bond, J.E.; Firk, F.W.K.

    1976-01-01

    The analyzing power of 4 He for neutron elastic scattering has been measured at four angles between 20 0 and 80 0 (lab) throughout the energy range 1.5-6.0 MeV using a double-scattering method. The intense flux of polarized neutrons was generated via the reactions Pb(γ, n)→ 12 C(n, n(pol.) 12 C, and the magnitude of the polarization of the neutron beam measured absolutely in a separate double-scattering experiment. Neutron energies were determined with a nanosecond time-of-flight spectrometer, and the generalized neutron spin-precession method was used to minimize systematic uncertainties. (Auth.)

  4. Analysis of a neutron scattering integral experiment on iron for neutron energies from 1 to 15 MeV

    International Nuclear Information System (INIS)

    Cramer, S.N.; Oblow, E.M.

    1976-11-01

    Monte Carlo calculations were made to analyze the results of an integral experiment with an iron sample to determine the adequacy of neutron scattering cross section data for iron. The experimental results analyzed included energy-dependent NE-213 detector count rates at a scattering angle of 90 deg and pulse-height spectra for scattered neutrons produced in an iron ring pulsed with a 1- to 20-MeV neutron source. The pulse-height data were unfolded to generate secondary neutron spectra at 90 deg as a function of incident neutron energy. Multigroup Monte Carlo calculations using the MORSE code and ENDF/B-IV cross sections were made to analyze all reported results. Discrepancies between calculated and measured responses were found for inelastic scattering reactions in the range from 1 to 4 MeV. These results were related to deficiencies in ENDF/B-IV iron cross section data

  5. Comprehensive Measurement of Neutron Yield Produced by 62 MeV Protons on Beryllium Target

    International Nuclear Information System (INIS)

    Osipenko, M.; Ripani, M.; Ricco, G.; Alba, R.; Schillaci, M.; Cosentino, L.; Del Zoppo, A.; Di Pietro, A.; Figuera, P.; Finocchiaro, P.; Maiolino, C.; Santonocito, D.; Scuderi, V.; Barbagallo, M.; Colonna, N.; Boccaccio, P.; Esposito, J.; Celentano, A.; Viberti, C.M.; Kostyukov, A.

    2013-06-01

    A low-power prototype of neutron amplifier, based on a 70 MeV, high current proton cyclotron being installed at LNL for the SPES RIB facility, was recently proposed within INFN-E project. This prototype uses a thick Beryllium converter to produce a fast neutron spectrum feeding a sub-critical reactor core. To complete the design of such facility the new measurement of neutron yield from a thick Beryllium target was performed at LNS. This measurement used liquid scintillator detectors to identify produced neutrons by Pulse Shape Discrimination and Time of Flight technique to measure neutron energy in the range 0.5-62 MeV. To extend the covered neutron energy range 3 He detector was used to measure neutrons below 0.5 MeV. The obtained yields were normalized to the charge deposited by the proton beam on the metallic Beryllium target. These techniques allowed to achieve a wide angular coverage from 0 to 150 degrees and to explore almost complete neutron energy interval. (authors)

  6. Advances in 14 MeV neutron activation analysis by means of a new intense neutron source

    International Nuclear Information System (INIS)

    Pepelnik, R.; Fanger, H.-U.; Michaelis, W.; Anders, B.

    1982-01-01

    A new intense 14 MeV neutron generator with cylindrical acceleration structure has been put in operation at the GKSS Research Center Geesthacht. The sealed neutron tube is combined with a fast pneumatic rabbit system with particular capabilities for neutron activation analysis involving short-lived reaction products. The sample transfer time is less than 140 ms. The maximum neutron flux available for activation is 5.2x10 10 n/cm 2 s. Theoretical sensitivity predictions made in a previous study have been verified for some important trace elements. As a first application, samples of freeze-dried suspended matter and fishes of the Elbe river were analyzed. (author)

  7. Neutron Energy Spectra from Neutron Induced Fission of 235U at 0.95 MeV and of 238U at 1.35 and 2.02 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Almen, E; Holmqvist, B; Wiedling, T

    1971-09-15

    The shapes of fission neutron spectra are of interest for power reactor calculations. Recently it has been suggested that the neutron induced fission spectrum of 235U may be harder than was earlier assumed. For this reason measurements of the neutron spectra of some fissile isotopes are in progress at our laboratory. This report will present results from studies of the energy spectra of the neutrons emitted in the neutron induced fission of 235U and 238U. The measurements were performed at an incident neutron energy of 0.95 MeV for 235U and at energies of 1.35 and 2.02 MeV for 238U using time-of-flight techniques. The time-of-flight spectra were only analysed at energies higher than those of the incident neutrons and up to about 10 MeV. Corrections for neutron attenuation in the uranium samples were calculated using a Monte Carlo program. The corrected fission neutron spectra were fitted to Maxwellian temperature distributions. For 235U a temperature of 1.27 +- 0.01 MeV gives the best fit to the experimental data and for 238U the corresponding values are 1.29 +- 0.03 MeV at 1.35 MeV and 1.29 +- 0.02 MeV at 2.02 MeV

  8. Conceptual design of 30 MeV magnet system used for BNCT epithermal neutron source

    International Nuclear Information System (INIS)

    Slamet Santosa; Taufik

    2015-01-01

    Conceptual design of 30 MeV Magnet System Used for BNCT Epithermal Neutron Source has been done based on methods of empirical model of basic equation, experiences of 13 MeV cyclotron magnet design and personal communications. In the field of health, cyclotron can be used as an epithermal neutron source for Boron Neutron Capture Therapy (BNCT). The development of cyclotron producing epithermal neutrons for BNCT has been performed at Kyoto University, of which it produces a proton beam current of 1.1 mA with energy of 30 MeV. With some experiences on 13 MeV cyclotron magnet design, to support BNCT research and development we performed the design studies of 30 MeV cyclotron magnet system, which is one of the main components of the cyclotron for deflecting proton beam into circular trajectory and serves as beam focusing. Results of this study are expected to define the parameters of particular cyclotron magnet. The scope of this study includes the study of the parameters component of the 30 MeV cyclotron and magnet initial parameters. The empirical method of basic equation model is then corroborated by a simulation using Superfish software. Based on the results, a 30 MeV cyclotron magnet for BNCT neutron source enables to be realized with the parameters of B 0 = 1.06 T, frequency RF = 64.733938 ≈ 65 MHz, the external radius of 0.73 m, the radius of the polar = 0.85 m, BH = 1.95 T and a gap hill of 4 cm. Because proton beam current that be needed for BNCT application is very large, then in the calculation it is chosen a great focusing axial νz = 0.630361 which can generate B V = 0.44 T. (author)

  9. Preliminary Study of the Efficacy of Using Nuclear Resonance Fluorescence with Quasi-Monoenergetic Gamma-Ray Sources for Nuclear Safeguards Assay

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, M S; McNabb, D P; Hall, J M; Gonzalez, J J

    2011-02-17

    We have studied the efficacy of using nuclear resonance fluorescence (NRF)-based techniques to assay spent nuclear fuel for Pu content using quasi-monoenergetic sources. We have developed two techniques to precisely determine the Pu content in a fuel rod/pin. One of our approaches is virtually free of systematic uncertainties. Using analytical models, we have determined the amount of time required to measure the Pu content in spent nuclear fuel rods and spent fuel assemblies to within 1% precision. We note that Pu content can be determined in a fuel assembly about as fast as in a single fuel pin. The performance of NRF-based assay techniques with improved photon sources, which are currently under development, will also estimated. For follow-on research we propose to: (1) Construct research prototype detection systems for both of the NRF-based assay systems proposed in this paper and measure their calibration curves; (2) Determine the systematic errors associated with both assay methods, explore ways to reduce the errors and fold the results into future performance calculations; (3) Develop an algorithm to assay a fuel assembly; (4) Perform validation measurements using a single pin and scaled assemblies; (5) Research and develop current-mode detection and/or threshold detection techniques to improve assay times; (6) Characterize the flux of newly constructed sources and fold the results into the calculations presented here to determine the feasibility of a variety of proposed sources; and (7) Collaborate with others in the safeguards community to build a prototype system and perform an NRF-based assay demonstration on spent fuel.

  10. Radioprotection shielding for neutrons induced by the reaction (2H (40 MeV, 12C

    Directory of Open Access Journals (Sweden)

    Fadil M.

    2017-01-01

    Full Text Available In the framework of design studies for SPIRAL2, the simulation of the neutron flux generated by 40 MeV deuterons on a thick 12C target was performed and compared to experimental data. The calculation of the dose rate of these neutrons allowed to compare four materials being considered for radioprotection shielding: barites, gypsum, ordinary concrete and heavy concrete. The simulated map of the neutron dose rate in the production building shows a very high dose rate around the neutron source and in the environment of some of the accelerator equipment.

  11. Gamma-ray-spectroscopy following high-flux 14-MeV neutron activation

    Energy Technology Data Exchange (ETDEWEB)

    Williams, R.E.

    1981-10-12

    The Rotating Target Neutron Source (RTNS-I), a high-intensity source of 14-MeV neutrons at the Lawrence Livermore National Laboratory (LLNL), has been used for applications in activation analysis, inertial-confinement-fusion diagnostic development, and fission decay-heat studies. The fast-neutron flux from the RTNS-I is at least 50 times the maximum fluxes available from typical neutron generators, making these applications possible. Facilities and procedures necessary for gamma-ray spectroscopy of samples irradiated at the RTNS-I were developed.

  12. Gamma-ray-spectroscopy following high-flux 14-MeV neutron activation

    International Nuclear Information System (INIS)

    Williams, R.E.

    1981-01-01

    The Rotating Target Neutron Source (RTNS-I), a high-intensity source of 14-MeV neutrons at the Lawrence Livermore National Laboratory (LLNL), has been used for applications in activation analysis, inertial-confinement-fusion diagnostic development, and fission decay-heat studies. The fast-neutron flux from the RTNS-I is at least 50 times the maximum fluxes available from typical neutron generators, making these applications possible. Facilities and procedures necessary for gamma-ray spectroscopy of samples irradiated at the RTNS-I were developed

  13. Neutron emission in fission of highly excited californium nuclei (E* = 76 MeV)

    International Nuclear Information System (INIS)

    Blinov, M.V.; Bordyug, V.M.; Kozulin, E.M.; Levitovich, M.; Mozhaev, A.N.; Muzychka, Yu.A.; Penionzhkevich, Yu.E.; Pustyl'nik, B.I.

    1990-01-01

    Differential cross sections for neutron production have been measured in fission of excited californium nuclei produced in the reaction 238 U + 12 C (105 MeV). It follows from analysis of the experimental results that the number of neutrons emitted before fission considerably exceeds the number obtained in the framework of the standard statistical model. On the basis of the multiplicity of neutrons they authors have estimated the time of fission of the excited nucleus. The dependence of the number of neutrons and their average energies on the mass of the fragments is determined

  14. Technical preparations for the in-vessel 14 MeV neutron calibration at JET

    International Nuclear Information System (INIS)

    Batistoni, P.; Popovichev, S.; Crowe, R.; Cufar, A.; Ghani, Z.; Keogh, K.; Peacock, A.; Price, R.; Baranov, A.; Korotkov, S.; Lykin, P.; Samoshin, A.

    2017-01-01

    Highlights: • The JET 14 MeV neutron calibration requires a neutron generator to be deployed inside the vacuum vessel by means of the remote handling system. • A neutron generator of suitable intensity and compliant with physics, remote handling and safety requirements has been identified and procured.The scientific programme of the preparatory phase devoted to fully characterizing the selected 14 MeV neutron generator is discussed. • The aim is to measure the absolute neutron emission rate within (± 5%) and the energy spectrum of emitted neutron as a function of angles. • The physics preparations, source issues, safety and engineering aspects required to calibrate directly the JET neutron detectors are discussed. - Abstract: The power output of fusion devices is measured from their neutron yields which relate directly to the fusion yield. In this paper we describe the devices and methods that have been prepared to perform a new in situ 14 MeV neutron calibration at JET in view of the new DT campaign planned at JET in the next years. The target accuracy of this calibration is ±10% as required for ITER, where a precise neutron yield measurement is important, e.g., for tritium accountancy. In this paper, the constraints and early decisions which defined the main calibration approach are discussed, e.g., the choice of 14 MeV neutron source and the deployment method. The physics preparations, source issues, safety and engineering aspects required to calibrate directly the JET neutron detectors are also discussed. The existing JET remote-handling system will be used to deploy the neutron source inside the JET vessel. For this purpose, compatible tooling and systems necessary to ensure safe and efficient deployment have been developed. The scientific programme of the preparatory phase is devoted to fully characterizing the selected 14 MeV neutron generator to be used as the calibrating source, obtain a better understanding of the limitations of the

  15. Technical preparations for the in-vessel 14 MeV neutron calibration at JET

    Energy Technology Data Exchange (ETDEWEB)

    Batistoni, P., E-mail: paola.batistoni@enea.it [ENEA, Department of Fusion and Nuclear Safety Technology, I-00044, Frascati, Rome (Italy); EUROfusion Consortium, Culham Science Centre, Abingdon, Oxon, OX14 3DB (United Kingdom); Popovichev, S. [CCFE, Culham Science Centre, Abingdon, Oxon, OX14 3DB (United Kingdom); EUROfusion Consortium, Culham Science Centre, Abingdon, Oxon, OX14 3DB (United Kingdom); Crowe, R. [Remote Applications in Challenging Environments (RACE), Culham Science Centre, Abingdon, Oxon, OX14 3DB (United Kingdom); EUROfusion Consortium, Culham Science Centre, Abingdon, Oxon, OX14 3DB (United Kingdom); Cufar, A. [Reactor Physics Division, Jožef Stefan Institute, Jamova cesta 39, SI-1000, Ljubljana (Slovenia); EUROfusion Consortium, Culham Science Centre, Abingdon, Oxon, OX14 3DB (United Kingdom); Ghani, Z. [CCFE, Culham Science Centre, Abingdon, Oxon, OX14 3DB (United Kingdom); EUROfusion Consortium, Culham Science Centre, Abingdon, Oxon, OX14 3DB (United Kingdom); Keogh, K. [Remote Applications in Challenging Environments (RACE), Culham Science Centre, Abingdon, Oxon, OX14 3DB (United Kingdom); EUROfusion Consortium, Culham Science Centre, Abingdon, Oxon, OX14 3DB (United Kingdom); Peacock, A. [JET Exploitation Unit, Abingdon, Oxon, OX14 3DB (United Kingdom); Price, R. [Remote Applications in Challenging Environments (RACE), Culham Science Centre, Abingdon, Oxon, OX14 3DB (United Kingdom); EUROfusion Consortium, Culham Science Centre, Abingdon, Oxon, OX14 3DB (United Kingdom); Baranov, A.; Korotkov, S.; Lykin, P.; Samoshin, A. [All-Russia Research Institute of Automatics (VNIIA), 22, Sushchevskaya str., 127055, Moscow (Russian Federation)

    2017-04-15

    Highlights: • The JET 14 MeV neutron calibration requires a neutron generator to be deployed inside the vacuum vessel by means of the remote handling system. • A neutron generator of suitable intensity and compliant with physics, remote handling and safety requirements has been identified and procured.The scientific programme of the preparatory phase devoted to fully characterizing the selected 14 MeV neutron generator is discussed. • The aim is to measure the absolute neutron emission rate within (± 5%) and the energy spectrum of emitted neutron as a function of angles. • The physics preparations, source issues, safety and engineering aspects required to calibrate directly the JET neutron detectors are discussed. - Abstract: The power output of fusion devices is measured from their neutron yields which relate directly to the fusion yield. In this paper we describe the devices and methods that have been prepared to perform a new in situ 14 MeV neutron calibration at JET in view of the new DT campaign planned at JET in the next years. The target accuracy of this calibration is ±10% as required for ITER, where a precise neutron yield measurement is important, e.g., for tritium accountancy. In this paper, the constraints and early decisions which defined the main calibration approach are discussed, e.g., the choice of 14 MeV neutron source and the deployment method. The physics preparations, source issues, safety and engineering aspects required to calibrate directly the JET neutron detectors are also discussed. The existing JET remote-handling system will be used to deploy the neutron source inside the JET vessel. For this purpose, compatible tooling and systems necessary to ensure safe and efficient deployment have been developed. The scientific programme of the preparatory phase is devoted to fully characterizing the selected 14 MeV neutron generator to be used as the calibrating source, obtain a better understanding of the limitations of the

  16. Measurement of double differential cross sections of secondary neutrons in the incident energy range 9-13 MeV

    International Nuclear Information System (INIS)

    Tang Hongqing; Qi Bujia; Zhou Zuying; Sa Jun; Ke Zunjian; Sui Qingchang; Xia Haihong; Shen Guanren

    1992-01-01

    The status and technique of double differential cross section measurement of secondary neutrons in the incident neutron energy range 9 to 13 MeV is reviewed with emphasis on the work done at CIAE. There are scarce measurements of secondary neutron double differential cross sections in this energy region up to now. A main difficulty for this is lack of an applicable monoenergetic neutron source. When monoenergetic neutron energy reaches 8 Me/v, the break-up neutrons from the d + D or p + T reaction starts to become significant. It is difficult to get a pure secondary neutron spectrum induced only by monoenergetic neutrons. To solve this problem an abnormal fast neutron TOF facility was designed and tested. Double differential neutron emission cross sections of 238 U and 209 Bi at 10 MeV were obtained by combining the data measured by both normal and abnormal TOF spectrometers and a good agreement between measurement and calculation was achieved

  17. Neutron-induced fission of uranium isotopes up to 100 MeV

    International Nuclear Information System (INIS)

    Lestone, J.P.; Gavron, A.

    1994-01-01

    The statistical-model description of the neutron-induced fission of U isotopes has been developed using densities of intrinsic states and spin cutoff parameters obtained directly from appropriate Nilsson model single-particle levels. The first-chance fission cross sections are reproduced well when the rotational contributions to the nuclear level densities are taken into account. In order to fit the U(n,f) cross sections above the threshold of second-chance fission, we must: (1) assume that the triaxial level-density enhancement is washed out at an excitation energy of approximately 7 MeV above the triaxial barriers with a width of approximately 1 MeV, implying a γ deformation for the first barriers where 10<γ<20 degree, and (2) include preequilibrium particle emission in the calculations. Above an incoming-neutron kinetic energy of approximately 17 MeV, our statistical model U(n,f) of cross sections increasingly overestimates the experimental data. This is not surprising since, at these high energies, little data exist on the scattering of neutrons to help guide the choice of optical-model parameters. A satisfactory reproduction of all of the available U(n,f) cross sections above 17 MeV is obtained by scaling our calculated compound-nucleus formation cross sections. This scaling factor falls from 1.0 at 17 MeV to 0.82 at 100 MeV

  18. Measure of uranium enrichment by 14 MeV neutron irradiation

    International Nuclear Information System (INIS)

    Rezende, H.R.

    1987-01-01

    A non-destructive technique for the determination of uranium in UO 2 samples was developed, marking use of the change in the fission cross of a nuclide with the neutron energy. The active interrogation method was used by irradiating the samples with pulsed 14 MeV neutrons and furtherdetection of delayed fission neutrons. In order to descriminated U-238 from U-235 the neutron energy was tailored by means of two concentric cylinders of lead and paraffin/poliethylene, 11 and 4 cm thick. Between neutron pulses, delayed neutrons from fission were detected by a long counter built with five BF 3 proportional counters. Calibration curves for enrichment and total mass versus delayed neutron response were obtained using available UO 2 pellets of Known enrichment. Enrichment detection limit, obtained with 95% confidence level by the the Student distribution was estimated to be 0.33%. The minimal detectable mass was estimated to be 4.4 g. (Author) [pt

  19. Measurement of uranium enrichment by 14 MeV neutron irradiation

    International Nuclear Information System (INIS)

    Rezende, H.R.

    1987-01-01

    a non-destructive technique for the determination of uranium in UO 2 samples was developed, making use of the change in the fission cross section of a nuclide with the neutron energy. The active interrogation method was used by irradiating the samples with pulsed 14 MeV neutrons and further detection of delayed fission neutrons. In order to discriminate U-238 from U-235 the neutron energy was tailored by means of two concentric cylinders of lead and paraffin/poliethylene, 11 and 4 cm thick. Between neutron pulses, delayed neutrons from fission were detected by a long counter built with five BF 3 proportional counters. Calibration curves for enrichment and total mass versus delayed neutron response were obtained using available UO 2 pellets of known enrichment. Enrichment detection limit, obtained with 95% confidence level by the Student distribution was estimated to be 0.33%. The minimal detectable mass was estimated to be 4.4 g. (author) [pt

  20. Neutron total and scattering cross sections of 6Li in the few MeV region

    International Nuclear Information System (INIS)

    Smith, A.; Guenther, P.; Whalen, J.

    1980-02-01

    Neutron total cross sections of 6 Li are measured from approx. 0.5 to approx. 4.8 MeV at intervals of approx. 10 scattering angles and at incident-neutron intervals of approx.< 100 keV. Neutron differential inelastic-scattering cross sections are measured in the incident-energy range 3.5 to 4.0 MeV. The experimental results are extended to lower energies using measured neutron total cross sections recently reported elsewhere by the authors. The composite experimental data (total cross sections from 0.1 to 4.8 MeV and scattering cross sections from 0.22 to 4.0 MeV) are interpreted in terms of a simple two-level R-matrix model which describes the observed cross sections and implies the reaction cross section in unobserved channels; notably the (n;α)t reaction (Q = 4.783 MeV). The experimental and calculational results are compared with previously reported results as summarized in the ENDF/B-V evaluated nuclear data file

  1. Removal cross section for 14 mev neutrons in constructional materials

    International Nuclear Information System (INIS)

    Vasvary, L.; Divos, F.; Peto, G.; Csikai, J.; Mumba, N.K.

    1985-01-01

    Using flight time difference the direct and scattered neutrons and gammas produced in the target head and samples were separated. With this method the attenuation of primary neutrons and gammas originating from the target head has been studied. Thickness dependence of the secondary gamma yield from extended samples of Al, Fe, Pb, paraffin and reinforced concrete was also measured. Results indicate a geometry dependence of the removal cross sections

  2. Container Inspection Utilizing 14 MeV Neutrons

    Science.gov (United States)

    Valkovic, Vladivoj; Sudac, Davorin; Nad, Karlo; Obhodas, Jasmina

    2016-06-01

    A proposal for an autonomous and flexible ship container inspection system is presented. This could be accomplished by the incorporation of an inspection system on various container transportation devices (straddle carriers, yard gentry cranes, automated guided vehicles, trailers). The configuration is terminal specific and it should be defined by the container terminal operator. This enables that no part of the port operational area is used for inspection. The inspection scenario includes container transfer from ship to transportation device with the inspection unit mounted on it. The inspection is performed during actual container movement to the container location. A neutron generator without associated alpha particle detection is used. This allows the use of higher neutron intensities (5 × 109 - 1010 n/s in 4π). The inspected container is stationary in the “inspection position” on the transportation device while the “inspection unit” moves along its side. The following analytical methods will be used simultaneously: neutron radiography, X-ray radiography, neutron activation analysis, (n, γ) and (n,n'γ) reactions, neutron absorption. and scattering, X-ray backscattering. The neutron techniques will utilize “smart collimators” for neutrons and gamma rays, both emitted and detected. The inspected voxel is defined by the intersection of the neutron generator and the detectors solid angles. The container inspection protocol is based on identification of discrepancies between the cargo manifest, elemental “fingerprint” and radiography profiles. In addition, the information on container weight is obtained during the container transport and screening by measuring of density of material in the container.

  3. Propagation of an ultra intense laser pulse in an under dense plasma: production of quasi monoenergetic electron beams and development of applications; Propagation d'une impulsion laser ultra-intense dans un plasma sous-dense: generation de faisceaux d'electrons quasi monoenergetiques et developpement d'applications

    Energy Technology Data Exchange (ETDEWEB)

    Glinec, Y

    2006-09-15

    This experimental study concerns the generation of electron beams with original properties. These electrons beams originate from the interaction of an ultra-intense and short laser pulse with a gas jet. Previously, these electron beams had a large divergence and a broad spectrum. A major improvement in this field was achieved when an electron beam with low divergence (10 mrad) and a peaked spectrum (170 MeV) was observed during this thesis, using a new single shot electron spectrometer. A parametric study of the interaction allowed to observe the evolution of the electron beam. Experiments have been carried out to deepen the characterization of the electron beam. The observation of transition radiation generated by the electrons at an interface shows that the electron beam interacts with the laser pulse during the acceleration. Radial oscillations of the electron beam around the laser axis, named betatron oscillations, were also observed on the electron spectra. Such a quasi-monoenergetic spectrum is essential for many applications. In order to justify the interest of this electron beam, several applications are presented: a sub-milli-metric gamma-ray radiography of dense objects, a dose profile of the electron beam comparable to present capabilities of photon sources for radiotherapy, a very short temporal profile useful for water radiolysis and the generation of a bright X-ray source with low divergence. (author)

  4. Propagation of an ultra intense laser pulse in an under dense plasma: production of quasi monoenergetic electron beams and development of applications; Propagation d'une impulsion laser ultra-intense dans un plasma sous-dense: generation de faisceaux d'electrons quasi monoenergetiques et developpement d'applications

    Energy Technology Data Exchange (ETDEWEB)

    Glinec, Y

    2006-09-15

    This experimental study concerns the generation of electron beams with original properties. These electrons beams originate from the interaction of an ultra-intense and short laser pulse with a gas jet. Previously, these electron beams had a large divergence and a broad spectrum. A major improvement in this field was achieved when an electron beam with low divergence (10 mrad) and a peaked spectrum (170 MeV) was observed during this thesis, using a new single shot electron spectrometer. A parametric study of the interaction allowed to observe the evolution of the electron beam. Experiments have been carried out to deepen the characterization of the electron beam. The observation of transition radiation generated by the electrons at an interface shows that the electron beam interacts with the laser pulse during the acceleration. Radial oscillations of the electron beam around the laser axis, named betatron oscillations, were also observed on the electron spectra. Such a quasi-monoenergetic spectrum is essential for many applications. In order to justify the interest of this electron beam, several applications are presented: a sub-milli-metric gamma-ray radiography of dense objects, a dose profile of the electron beam comparable to present capabilities of photon sources for radiotherapy, a very short temporal profile useful for water radiolysis and the generation of a bright X-ray source with low divergence. (author)

  5. Transmission test of the polyethylene shield against 40 and 65 MeV quasi monochrome neutron

    International Nuclear Information System (INIS)

    Nakao, Makoto; Nakamura, Takashi; Sakuya, Yoshimasa; Nauchi, Yasushi; Nakao, Noriaki; Tanaka, Susumu; Sakamoto, Yukio; Nakajima, Hiroshi; Nakane, Yoshihiro.

    1996-01-01

    Using 40 and 65 MeV quasi monochrome neutron of the AVF cyclotron installed at Takasaki Laboratory, Japan Atomic Energy Research Institute, the neutron energy spectra were measured after transmitting the polyethylene shield. Results of the shielding experiments using concrete and iron recognized as main shielding material were proposed previously. As data obtained in the experiments were useful for a bench-mark experiment to investigate for shielding calculation and sectional data set, a shielding calculation simulated with new experiment to compare with and investigate for the previous experimental data. As a result, it was found that calculation result of neutron flux transmitting through the polyethylene shield showed difference with increase of the shield thickness. And, reducing distance of the peak neutron was also found to be over-estimated in its calculation value, such as three and five times on 43 MeV at 120 and 180 cm thick, respectively. (G.K.)

  6. Measurements of 14 MeV neutron multiplication in spherical beryllium shells

    International Nuclear Information System (INIS)

    Moellendorff, U. von; Alevra, A.V.; Giese, H.; Kappler, F.; Klein, H.; Klein, H.; Tayama, R.

    1995-01-01

    New results of spherical-shell transmission measurements with 14MeV neutrons on pure beryllium shells up to 17cm thick are reported. The total leakage neutron multiplications were measured using a Bonner sphere system. Independently, the leakage neutron spectra were measured over the entire energy range, 15MeV to thermal energies, by proton-recoil and time-of-flight methods. The total leakage multiplications are in excellent agreement with three-dimensional Monte Carlo calculations using beryllium nuclear data based on the Young and Stewart evaluation. The leakage in the evaporation energy window confirms the Be(n,2n) cross-section of the Young and Stewart evaluation rather than that used in the ENDF/B-VI library. At energies below 1keV, a surplus of leakage neutrons over the calculation is found for smaller beryllium thicknesses. (orig.)

  7. Determination of oxygen content in steel using activation analysis with 14 MeV neutron

    International Nuclear Information System (INIS)

    Calado, C.E.

    1978-01-01

    In the quantitative analysis of oxygen in steel by fast neutron activation analysis the oxygen content is evaluated from the measured activity of 16 N produced. Steel s mples are irradiated in 14 MeV neutron flux. After irradiation the samples are pneumatically transfered to the counting terminal where activity is measured. Oxygen concentrations, are obtained by comparison with standards of specified oxygen content [pt

  8. Determination of the emission rate for the 14 MeV neutron generator with the use of radio-yttrium

    OpenAIRE

    Laszynska Ewa; Jednorog Slawomir; Ziolkowski Adam; Gierlik Michal; Rzadkiewicz Jacek

    2015-01-01

    The neutron emission rate is a crucial parameter for most of the radiation sources that emit neutrons. In the case of large fusion devices the determination of this parameter is necessary for a proper assessment of the power release and the prediction for the neutron budget. The 14 MeV neutron generator will be used for calibration of neutron diagnostics at JET and ITER facilities. The stability of the neutron generator working parameters like emission and angular homogeneity affects the accu...

  9. Cross-section calculations for neutron-induced reactions up to 50 MeV

    International Nuclear Information System (INIS)

    Yamamuro, Nobuhiro.

    1996-01-01

    In the field of accelerator development, medium-energy reaction cross-section data for structural materials of accelerator and shielding components are required, especially for radiation protection purposes. For a d + Li stripping reaction neutron source used in materials research, neutron reaction cross sections up to 50 MeV are necessary for the design study of neutron irradiation facilities. The current version of SINCROS-II is able to calculate neutron and proton-induced reaction cross sections up to ∼ 50 MeV with some modifications and extensions of the cross-section calculation code. The production of isotopes when structural materials and other materials are bombarded with neutrons or protons is calculated using a revised code in the SINCROS-II system. The parameters used in the cross-section calculations are mainly examined with proton-induced reactions because the experimental data for neutrons above 20 MeV are rare. The status of medium mass nuclide evaluations for aluminum, silicon, chromium, manganese, and copper is presented. These data are useful to estimate the radiation and transmutation of nuclei in the materials

  10. Proposed 14-MeV neutron spectrometer system for jet

    International Nuclear Information System (INIS)

    Elevant, T.

    1983-09-01

    In order to cover a broad range of neutron spectra and fluxes during D-T operation in JET we propose the use of two different detector techniques neutron induced reactions in a silicon surface barrier detector and neutron-proton elastic scattering in a liquid scintillator. Experimental investigations of 28 Si(n,α) 25 Mg reactions have resulted in resolutions of ΔE(FWHM)/E=0.02 with intrinsic efficiency equal to 10 -4 and a maximum useful countrate equal to 1600 c.p.s. However, due to overlap of adjacent peaks, caused by excited states of 25 Mg, this spectrometer has an operation range limited to FWHM/E=0.04. For broader neutron distributions we propose the use of a conventional liquid scintillator system with a light guide, photomultiplier tube and modified conventional electronics. Experiments have demonstrated a resolution equal to 0.05 and a n/γ separation better than 90percent at total countrates equal to 2times10 5 c.p.s. (author)

  11. Transmission of 14 MeV neutrons through concrete, soil, sugar, wood and coal samples - a Monte Carlo Study

    International Nuclear Information System (INIS)

    Abdelmonem, M.S.; Naqvi, A.A.

    2006-01-01

    Full text: Fast neutrons transmission measurements are ideal for the elemental analysis of bulk samples. In particular, they can be used to determine the hydrogen concentration in bulk samples. In the present study, Monte Carlo simulations have been carried to calculate the intensity of 14 MeV neutrons transmitted through concrete, soil, sugar, wood and coal samples. The simulated set-up consists of a cylindrical sample, placed at a distance of 9 cm from the neutron source. Fast neutrons transmitted through the sample are collimated through a double truncated neutron collimator to a fast neutron detector. The collimator contains a mixture of paraffin and lithium carbonate. In this study, transmitted intensity of fast neutron through each sample was calculated as a function of moisture contents of the sample for 14 MeV neutrons. The moisture contents of the samples were varied over 0-7 wt. %. The calculated intensity of 14 MeV neutrons transmitted through the samples, shows effects related to fast neutron thermalization in hydrogen of moisture and energy dependence of neutron transmission through the sample materials. This is clearly shown by different gradients of neutron yield vs moisture content curves of these samples. The gradient of the neutron yield curves for the 14 MeV neutrons has a lower value than those reported for a 241 Am-Be neutron source

  12. Energy measurement of prompt fission neutrons in 239Pu(n,f) for incident neutron energies from 1 to 200 MeV

    CERN Document Server

    Chatillon, A; Granier, Th; Laurent, B; Taïeb, J; Noda, S; Haight, R C; Devlin, M; Nelson, R O; O’Donnell, J M

    2010-01-01

    Prompt fission neutron spectra in the neutron-induced fission of 239Pu have been measured for incident neutron energies from 1 to 200 MeV at the Los Alamos Neutron Science Center. Preliminary results are discussed and compared to theoretical model calculation.

  13. Neutron-proton elastic scattering between 200 and 500 MeV

    International Nuclear Information System (INIS)

    Clough, A.S.; Gibson, D.R.; Axen, D.

    1979-01-01

    Measurements over an extensive angular range of the Dsub(t) and P parameters in free neutron-proton elastic scattering at laboratory energies of 220, 325, 425 and 495 MeV are reported. Experimental and analytical details are given. (author)

  14. Neutron cross-sections above 20 MeV for design and modeling of ...

    Indian Academy of Sciences (India)

    bination of a high-power, high-energy accelerator, a spallation target for neutron ... The development of the commercial critical reactors of today motivated a large effort on nuclear data up to about 20 MeV, and presently ..... facility in the world.

  15. 14.2 MeV neutron induced U-235 fission cross section measurement

    International Nuclear Information System (INIS)

    Li Jingwen; Shen Guanren; Ye Zongyuan; Li Anli; Zhou Shuhua; Sun Zhongfan; Wu Jingxia; Huang Tanzi

    1986-01-01

    The cross section of U-235 fission induced by 14.2 MeV neutrons was measured by the time correlated associated particle method. The result obtained is (2.078+-0.040) barn. Comparison with other author's is also given. (author)

  16. Calculation of neutron cross sections on iron up to 40 MeV

    International Nuclear Information System (INIS)

    Arthur, E.D.; Young, P.G.

    1980-01-01

    The development of high energy d + Li neutron sources for fusion materials radiation damage studies will require neutron cross sections up to 40 MeV. Experimental data above 15 MeV are generally sparse or nonexistent, and reliance must be placed upon nuclear-model calculations to produce the needed cross sections. To satisfy such requirements for the Fusion Materials Irradiation Test Facility (FMIT), neutron cross sections have been calculated for 54 56 Fe between 3 and 40 MeV. These results were joined to the existing ENDF/B-V evaluation below 3 MeV. In this energy range, most neutron reactions can be described using the Hauser-Feshbach statistical model with corrections for preequilibrium and direct-reaction effects. To properly use these models to obtain realistic cross sections, emphasis must be placed upon the determination of suitable input parameters (optical model sets, gamma-ray strength functions, level densities) valid over the energy range of the calculation. To do this, several types of independent data were used to arrive at consistent parameter sets as described

  17. Fast neutron detection with germanium detectors: computation of response functions for the 692 keV inelastic scattering peak

    International Nuclear Information System (INIS)

    Fehrenbacher, G.; Meckbach, R.; Paretzke, H.G.

    1996-01-01

    The dependence of the shape of the right-sided broadening of the inelastic scattering peak at 692 keV in the pulse-height distribution measured with a Ge detector in fast neutron fields on the energy of the incident neutrons has been analyzed. A model incorporating the process contributing to the energy deposition that engender the peak, including the partitioning of the energy deposition by the Ge recoils, was developed. With a Monte Carlo code based on this model, the detector response associated with this peak was computed and compared with results of measurements with quasi-monoenergetic neutrons for energies between 0.88 and 2.1 MeV. A set of 80 response functions for neutron energies in the range from the reaction threshold at 0.7 to 6 MeV was computed, which will serve as a starting point for methods, which aim at obtaining information on the spectral distribution of fast neutron fields for this energy range from measurements with a Ge detector. (orig.)

  18. Scattering of 14.6 MeV neutrons from Fe and evidence for structure in the emitted neutron spectra

    International Nuclear Information System (INIS)

    Gul, K.; Anwar, M.; Ahmad, M.; Saleem, S.M.; Khan, N.A.

    1984-06-01

    Structure in the spectra of neutrons emitted from iron on bombardment with 14.6 MeV neutrons has been investigated and explained in terms of excitation of levels in iron 56. The energies of scattered neutrons have been measured by the time-of-flight technique based on the associated particle method. The observed excitations have been correlated with the reported levels in a satisfactory manner. Evidence for new excitations at 8.8 +- 0.02, 9.8 +- 0.1, 10.2 +- 0.1, 12.44 +- 0.03 and 12.52 +- 0.03 MeV has been obtained. The excitation of possible components of Ml giant resonance in iron 56 is discussed. (author)

  19. Nuclear and activation characteristics of materials in 14.1-MeV and 2.5-MeV neutron field

    International Nuclear Information System (INIS)

    Seki, Yasushi; Takeyasu, Yuuichi.

    1988-11-01

    The nuclear and activation characteristics of various materials and elements of interest in terms of fusion reactor design are calculated and the results are graphically shown. The elements and materials are placed in a simple geometry modelling a blanket and shield of a fusion reactor. The neutrons with 14.1-MeV and 2.5-MeV energy are generated from the region represented as D-T and D-D plasma, respectively. The following activation characteristics after neutron irradiation are shown for each material and element; 1. Time evolution of induced activity, 2. Time evolution of decay heat, 3. Delayed gamma-ray dose distribution, 4. Decay heat distribution. In addition to the above activation characteristics, nuclear characteristics during the neutron irradiation, e.g. neutron energy spectra, neutron and gamma-ray flux distribution, nuclear heating distributions, and neutron and gamma-ray dose rate are also shown. (author)

  20. Interaction of 14 MeV neutrons with hydrogenated target proton emission calculation

    International Nuclear Information System (INIS)

    Martin, G.; Perez, N.; Desdin.

    1996-01-01

    Using neutron emission data of a 14 MeV neutron generator, a paraffin target, and based on the n + H 1 → n '+ p reaction, have been obtained the characteristics of the proton emission in a proton-neutron mixed field. It was used Monte Carlo simulation and it was obtained the proton output as function of the converter width and the energy spectrum of protons corresponding to different converter thickness. Among 0.07 and 0.2 cm there is a maximum zone for the proton emission. The energy spectrum agrees with obtained on previous papers. Figures showing these results are provided

  1. Neutron cross section standards for the energy region above 20 MeV

    International Nuclear Information System (INIS)

    1991-01-01

    These proceedings of a specialists' meeting on Neutron cross section standards for the energy region above 20 MeV are divided into 6 sessions bearing on: - session 1: status of the date base for (n-p) scattering (2 conferences) - session 2: status of nucleon-nucleon phase shift calculations (1 conference) - session 3: recent and planned experimental work on n-p cross section measurements and facilities (7 conferences) - session 4: Instruments for utilizing the H (n.n) standard for neutron fluence measurement (4 conferences) - session 5: proposal for other neutron cross-section standards (4 conferences) - session 6: monitor reactions for radiation dosimetry (3 conferences)

  2. A 14 MeV neutron irradiation facility with an automated fast cyclic pneumatic

    International Nuclear Information System (INIS)

    Montgomery, M.T.; Yoho, M.D.; Biegalski, S.R.; Landsberger, S.; Welch, L.

    2016-01-01

    This work details the design criteria, construction, controls, and optimization of the 14 MeV neutron irradiation facility at the University of Texas, built with the motivation of performing neutron activation analysis on samples with short half-lives. The facility couples a D-T neutron generator with a pneumatic transfer system capable of transit of approximately one second between source and detector, while the cyclic automated nature allows for many irradiation/count trials with any number of samples, translating to significantly improved counting statistics. (author)

  3. Optimization calculations for slow neutron production with the 136 MeV Harwell electron linac

    International Nuclear Information System (INIS)

    Needham, J.; Sinclair, R.N.

    1978-10-01

    The new 136 MeV Harwell electron linac is to be used to produce pulsed beams of slow neutrons for condensed matter research. Design details and performance of the two types of moderator which will be available have been optimised using a Monte Carlo neutronics code (TIMOC). The choice of reflector, the necessary decoupling energy to prevent pulse broadening and the influence of γ shields and moderator shape have been investigated. The predicted yield of leakage neutrons of energy 1 eV is compared to published values for comparable facilities. (author)

  4. Measurement of the angular distribution of neutron-proton scattering at 10 MeV

    International Nuclear Information System (INIS)

    Haight, R.C.; Bateman, F.B.; Grimes, S.M.; Brient, C.E.; Massey, T.N.; Wasson, O.A.; Carlson, A.D.; Zhou, H.

    1995-01-01

    The relative angular distribution of neutrons scattered from protons was measured at an incident neutron energy of 10 MeV at the Ohio University Accelerator Laboratory. An array of 11 detector telescopes at laboratory angles of 0 to 60 degrees was used to detect recoil protons from neutron interactions with a CH 2 (polypropylene) target. Data for 7 of these telescopes were obtained with one set of electronics and are presented here. These data, from 108 to 180 degrees for the center-of-mass scattering angles, have a small slope which agrees better with angular distributions predicted by the Arndt phase shifts than with the ENDF/B-VI angular distribution

  5. Neutron quality parameters versus energy below 4 MeV from microdosimetric calculations

    International Nuclear Information System (INIS)

    Stinchcomb, T.G.; Borak, T.B.

    1983-01-01

    Charged-particle production by neutrons and the resulting energy-deposition spectra in micron-sized spheres of tissue of varying diameters were calculated from thermal energies to 4 MeV. These data were used to obtain dose-average values of several quality-indicating parameters as functions of neutron energy and of tissue sphere diameter. The contrast among the parameters is shown and discussed. Applications are made to two neutron spectra, one a fission spectrum in air and the other a moderated spectrum at the center of an irradiated cube of water

  6. Neutron shielding verification measurements and simulations for a 235-MeV proton therapy center

    International Nuclear Information System (INIS)

    Newhauser, W.D.; Titt, U.; Dexheimer, D.; Yan, X.; Nill, S.

    2002-01-01

    The neutron shielding at the Massachusetts General Hospital's 235-MeV proton therapy facility was investigated with measurements, analytical calculations, and realistic three-dimensional Monte Carlo simulations. In 37 of 40 cases studied, the analytical calculations predicted higher neutron dose equivalent rates outside the shielding than the measured, typically by more than a factor of 10, and in some cases more than 100. Monte Carlo predictions of dose equivalent at three locations are, on average, 1.1 times the measured values. Except at one location, all of the analytical model predictions and Monte Carlo simulations overestimate neutron dose equivalent

  7. A 14-MeV beam-plasma neutron source for materials testing

    International Nuclear Information System (INIS)

    Futch, A.H.; Coensgen, F.H.; Damm, C.C.; Molvik, A.W.

    1989-01-01

    The design and performance of 14-MeV beam-plasma neutron sources for accelerated testing of fusion reactor materials are described. Continuous production of 14-MeV neutron fluxes in the range of 5 to 10 MW/m 2 at the plasma surface are produced by D-T reactions in a two-component plasma. In the present designs, 14-MeV neutrons result from collisions of energetic deuterium ions created by transverse injection of 150-keV deuterium atoms on a fully ionized tritium target plasma. The beam energy, which deposited at the center of the tritium column, is transferred to the warm plasma by electron drag, which flows axially to the end regions. Neutral gas at high pressure absorbs the energy in the tritium plasma and transfers the heat to the walls of the vacuum vessel. The plasma parameters of the neutron source, in dimensionless units, have been achieved in the 2XIIB high-β plasma. The larger magnetic field of the present design permits scaling to the higher energy and density of the neutron source design. In the extrapolation, care has been taken to preserve the scaling and plasma attributes that contributed to equilibrium, magnetohydrodynamic (MHD) stability, and microstability in 2XIIB. The performance and scaling characteristics are described for several designs chosen to enhance the thermal isolation of the two-component plasmas. 11 refs., 3 figs., 3 tabs

  8. Evaluation of neutron cross sections to 40 MeV for 5456Fe

    International Nuclear Information System (INIS)

    Arthur, E.D.; Young, P.G.

    1980-01-01

    Cross sections for neutron-induced reactions on 54 56 Fe were calculated by employing several nuclear models: optical, Hauser-Feshbach, preequilibrium and DWBA - in the energy range between 3 and 40 MeV. As a prelude to the calculations, the necessary input parameters were determined or verified through analysis of a large body of experimental data for both neutron- and proton-induced reactions in this mass and energy region. This technique also led to cross sections in which the simultaneous influence of available data types added to their consistency and reliability. Calculated cross sections as well as neutron and gamma-ray emission spectra were incorporated into an ENDF evaluation suitable for use to 40 MeV. 12 figures, 1 table

  9. Scattering of 14.2 MeV polarized neutrons from 12C

    International Nuclear Information System (INIS)

    Casparis, R.; Leemann, B.Th.; Preiswerk, M.; Rudin, H.; Wagner, R.; Zupranski, P.

    1976-01-01

    Polarized 14.2 MeV neutrons with a polarization of approximately 50% were produced in the 3 H(d(pol),n(pol)) 4 He reaction using vector polarized deuterons from an 'atomic beam' source of polarized ions. The angular distributions of the analyzing power in the elastic and inelastic (Q = -4.43 MeV) scattering of neutrons from carbon have been measured at ten angles in the range from 22 0 to 152 0 c.m. A time-of-flight technique was used to separate elastically and inelastically scattered neutrons. The results have been compared with theoretical calculations obtained with the DWBA and the coupled channels method. (Auth.)

  10. Low-temperature irradiation of niobium with 15-MeV neutrons

    International Nuclear Information System (INIS)

    Kerchner, H.R.; Coltman, R.R. Jr.; Klabunde, C.E.; Sekula, S.T.

    1978-01-01

    Niobium was irradiated at 4.2 K with high energy d-Be neutrons to a fluence of 3.7x10 15 n/cm 2 . The neutrons were generated at the Oak Ridge Isochronous Cyclotron by the breakup reaction of 40-MeV deuterons in a thick Be target. The resulting neutron energy spectrum was broadly peaked near 15 MeV. The 0.012-cm-diameter wire sample (RRR=200) was situated in a uniform transverse magnetic field. The critical current, flux flow resistance, and normal state resistance were measured by using a standard four-terminal technique. The critical current density and the flux flow resistivity were observed to increase with irradiation and to decrease toward the preirradiation values with subsequent isochronal annealing between 4.2 K and 360 K. Using recent theories of flux line lattice deformation, the elementary pinning force is deduced and the result is compared to theoretical calculations. (Auth.)

  11. Simulation code for the interaction of 14 MeV neutrons on cells

    Energy Technology Data Exchange (ETDEWEB)

    Nenot, M.L.; Alard, J.P.; Dionet, C.; Arnold, J.; Tchirkov, A.; Meunier, H.; Bodez, V.; Rapp, M.; Verrelle, P

    2002-07-01

    The structure of the survival curve of melanoma cells irradiated by 14 MeV neutrons displays unusual features at very low dose rate where a marked increase in cell killings at 0.05 Gy is followed by a plateau for survival from 0.1 to 0.32 Gy. In parallel a simulation code was constructed for the interaction of 14 MeV neutrons with cellular cultures. The code describes the interaction of the neutrons with the atomic nuclei of the cellular medium and of the external medium (flask culture and culture medium), and is used to compute the deposited energy into the cell volume. It was found that the large energy transfer events associated with heavy charged recoil can occur and that a large part of the energy deposition events are due to recoil protons emitted from the external medium. It is suggested that such events could partially explain the experimental results. (author)

  12. A neutron survey meter with sensitivity extended up to 400 MeV

    International Nuclear Information System (INIS)

    Birattari, C.; Silari, M.

    1992-01-01

    The well-known Andersson-Braun rem counter is widely employed for radiation protection purposes, but its efficiency shows a marked decrease for neutron energies above about 10 MeV. Since the availability of a survey meter with a good sensitivity to higher energies can be very useful, for instance, at many particle accelerator facilities, a neutron monitor with a response function extended up to 400 MeV has been achieved by modifying the structure of the moderator-attenuator of a commercial instrument. The first experimental tests carried out to verify the response of the new monitor both to low and high energy neutrons are reported. A comparison with the response function of three conventional commercial rem counters is presented. (author)

  13. The design of a proton recoil telescope for 14 MeV neutron spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Hawkes, N.P.; Bond, D.S.; Croft, S.; Jarvis, O.N. E-mail: onj@jet.uk; Sherwood, A.C

    2002-01-01

    As part of the design effort for a 14 MeV neutron spectrometer for the Joint European Torus (JET), computer codes were developed to calculate the response of a proton recoil telescope comprising a proton radiator film mounted in front of a proton detector. The codes were used to optimise the geometrical configuration in terms of efficiency and resolution, bearing in mind the constraints imposed by the proposed application as a JET neutron diagnostic for the Deuterium-Tritium phase. A prototype instrument was built according to the optimised design, and tested with monoenergetic 14 MeV neutrons from the Harwell 500 keV Van de Graaff accelerator. The measured energy resolution and absolute efficiency were found to be in acceptable agreement with the calculations. Based on this work, a multi-radiator production version of the spectrometer has now been constructed and successfully deployed at JET.

  14. The design of a proton recoil telescope for 14 MeV neutron spectrometry

    International Nuclear Information System (INIS)

    Hawkes, N.P.; Bond, D.S.; Croft, S.; Jarvis, O.N.; Sherwood, A.C.

    2002-01-01

    As part of the design effort for a 14 MeV neutron spectrometer for the Joint European Torus (JET), computer codes were developed to calculate the response of a proton recoil telescope comprising a proton radiator film mounted in front of a proton detector. The codes were used to optimise the geometrical configuration in terms of efficiency and resolution, bearing in mind the constraints imposed by the proposed application as a JET neutron diagnostic for the Deuterium-Tritium phase. A prototype instrument was built according to the optimised design, and tested with monoenergetic 14 MeV neutrons from the Harwell 500 keV Van de Graaff accelerator. The measured energy resolution and absolute efficiency were found to be in acceptable agreement with the calculations. Based on this work, a multi-radiator production version of the spectrometer has now been constructed and successfully deployed at JET

  15. Calibration of a large multi-element neutron counter in the energy range 85-430 MeV

    CERN Document Server

    Strong, J A; Esterling, R J; Garvey, J; Green, M G; Harnew, N; Jane, M R; Jobes, M; Mawson, J; McMahon, T; Robertson, A W; Thomas, D H

    1978-01-01

    Describes the calibration of a large 60 element neutron counter with a threshold of 2.7 MeV equivalent electron energy. The performance of the counter has been measured in the neutron kinetic energy range 8.5-430 MeV using a neutron beam at the CERN Synchrocyclotron. The results obtained for the efficiency as a function of energy are in reasonable agreement with a Monte Carlo calculation. (7 refs).

  16. Experiment and analysis of neutron spectra in a concrete assembly bombarded by 14 MeV neutrons

    International Nuclear Information System (INIS)

    Oishi, Koji; Tomioka, Kazuyuki; Ikeda, Yujiro; Nakamura, Tomoo.

    1988-01-01

    Neutron spectrum in concrete bombarded by 14 MeV neutrons was measured using a miniature NE213 spectrometer and multi-foil activation method. A good agreement between those two experimental methods was obtained within experimental errors. The measured spectrum was compared with calculated ones using two-dimensional transport code DOT3.5 with 125 group structure cross section libraries based on ENDF/B-IV, JENDL-2, and JENDL-3T (the testing version of JENDL-3.) In the D-T neutron peak region, measured and calculated neutron spectra agreed well with each other for those libraries. However, disagreements of about -10 % to +50 % and -30 % to +40 % were obtained in the MeV region and still lower neutron energy range, respectively. As a result, it was concluded that those discrepancies were caused by the overestimation of secondary neutrons emitted by inelastic scattering from O, Si, and/or Ca which were the main components of concrete. (author)

  17. Calculation of Multisphere Neutron Spectrometer Response Functions in Energy Range up to 20 MeV

    CERN Document Server

    Martinkovic, J

    2005-01-01

    Multisphere neutron spectrometer is a basic instrument of neutron measurements in the scattered radiation field at charged-particles accelerators for radiation protection and dosimetry purposes. The precise calculation of the spectrometer response functions is a necessary condition of the propriety of neutron spectra unfolding. The results of the response functions calculation for the JINR spectrometer with LiI(Eu) detector (a set of 6 homogeneous and 1 heterogeneous moderators, "bare" detector within cadmium cover and without it) at two geometries of the spectrometer irradiation - in uniform monodirectional and uniform isotropic neutron fields - are given. The calculation was carried out by the code MCNP in the neutron energy range 10$^{-8}$-20 MeV.

  18. The sensitivity of RTL, RPL and photographic detectors to 14.7MeV neutrons

    International Nuclear Information System (INIS)

    Spurny, Frantisek; Medioni, Roger; Portal, Guy.

    1975-08-01

    The sensitivity of various types of γ detectors to neutrons should be known for a better dosimetry of electromagnetic radiations in neutron fields. The sensitivity of various types of detectors to 14.7MeV neutrons was studied using RTL (LiF, 7 LiF, Ca SO 4 : Dy Al 2 O) RPL (C.E.C. glasses) and photographic detectors (Kodak-Pathe dosemeters). The methods used for the determination of the neutron and photon mixed field are described and the effect of containers and packing on the accuracy of results was investigated. For each detector studied the specific sensitivity to neutrons (sensitivity of the product alone) and the apparent sensitivity in usual operating conditions (action of surrounding materials) is given [fr

  19. Track-etch dosemeter response to neutrons up to 300 MeV

    International Nuclear Information System (INIS)

    Devine, R.T.; Walker, S.; Staples, P.; Duran, M.; Mundis, R.; Miller, J.

    1996-01-01

    Electro-chemical and chemical track-etch dosemeters were obtained from commercial suppliers and exposed to neutrons produced at the LANTF WNR white neutron source at 15 degree with no shielding and filtered by polyethylene blocks of 2.5, 5.1, 10.2, 20.3 and 40.6 cin thickness. The neutron spectrum was determined using calculations. Mean energies from 28 to 300 MeV were produced. Dose was calculated from the NCRP-38 flux-to-dose conversion. The results are compared with NTA film which was exposed in the same configuration. The response of track etch dosimeters was found to reach a minimum and then rise as the average neutron energy increased. The response of the NTA film increased as the neutron energy increased

  20. Neutron doses to personnel from a 24 MeV betatron

    International Nuclear Information System (INIS)

    Beckham, W.A; Entwistle, R.F.

    1987-01-01

    Neutrons are produced by bombardment of most materials by high-energy photons. Because the x-ray shielding around high-energy x-ray generators may not have been designed with neutrons in mind there may be unexpected contributions to the radiation doses of staff working in the immediate vicinity. Neutron fluxes in the working area close to an Allis-Chalmers 24 MeV betatron have been measured using a lithium-6-loaded scintillator and the dose rates calculated. Hazard of staff has been found to be low; typical dose-equivalent rates in occupied areas range from 0.0042 to 0.012 mrem/hour. The flux of fast neutrons in the treatment room was found to be essentially zero. Measurements of neutron flux may be routinely performed using the scintillation detector (NE 912) described, and could usefully form part of the acceptance protocol for any new accelerator

  1. Neutron multiplicity in deep inelastic collisions: 400 MeV Cu + Au system

    International Nuclear Information System (INIS)

    Tamain, B.; Chechik, R.; Ruchs, H.; Hanappe, F.; Morjean, M.; Ngo, C.; Peter, J.; Dakowski, M.; Lucas, B.; Mazur, C.; Ribrag, M.; Signarbieux, C.

    1979-01-01

    The authors have detected in nine different positions of space the neutrons associated with the collision of 63 Cu on 197 Au at 400 MeV bombarding energy. The deep inelastic products were detected at two different angles: close to the gazing angle and 30 0 forwards of it. Their measses were measured using a time-of-flight technique. The neutrons were detected in coincidence with the fragments - the efficiency of the neutron detectors was measured relatively to a 252 Cf source during beam time. The neutron threshold was set at 300 keV. Within an accuracy of 10% all the emitted neutrons are evaporated by the fully accelerated deep inelastic fragments. It is shown that the excitation energy is shared between the fragments in proportion to their masses and that the relaxation time for internal equilibration of the composite system is very short (approximately 10 -22 s). (Auth.)

  2. A comparison of the free vacancy production in α brass by fission reactor neutrons and 14.8-MeV neutrons

    International Nuclear Information System (INIS)

    Damask, A.C.; Van Konynenburg, R.; Borg, R.J.; Dienes, G.J.

    1976-01-01

    Enhancement of substitutional diffusion is observed in α brass (30 wt% Zn) by following the decrease in electrical resistivity with neutron irradiation of a thermally equilibrated alloy; the decrease arises from the increase in short-range order. It was determined by previous research that this diffusion enhancement is largely caused by the annealling of radiation-produced vacancies in excess of the thermal equilibrium concentration. Therefore, the results reported here are based upon a well-established technique. The rate of resistivity change per neutron of different energies will give the relative number of free vacancies produced per neutron. This experiment compares the effect of 14.8 MeV neutrons with neutrons from a fission reactor. The results indicate that 14.8 MeV neutrons produce 10 +- 2 times as many free vacancies as reactor neutrons when the latter are expressed in terms of those neutrons with energies greater than 0.1 MeV. (author)

  3. High energy proton simulation of 14-MeV neutron damage in Al2O3

    International Nuclear Information System (INIS)

    Muir, D.W.; Bunch, J.M.

    1975-01-01

    High-energy protons are a potentially useful tool for simulating the radiation damage produced by 14-MeV neutrons in CTR materials. A comparison is given of calculations and measurements of the relative damage effectiveness of these two types of radiation in single-crystal Al 2 O 3 . The experiments make use of the prominent absorption band at 206 nm as an index to lattice damage, on the assumption that peak absorption is proportional to the concentration of lattice vacancies. The induced absorption is measured for incident proton energies ranging from 5 to 15 MeV and for 14-MeV neutrons. Recoil-energy spectra are calculated for elastic and inelastic scattering using published angular distributions. Recoil-energy spectra also are calculated for the secondary alpha particles and 12 C nuclei produced by (p,p'α) reactions on 16 O. The recoil spectra are converted to damage-energy spectra and then integrated to yield the damage-energy cross section at each proton energy and for 14 MeV neutrons. A comparison of the calculations with experimental results suggests that damage energy, at least at high energies, is a reasonable criterion for estimating this type of radiation damage. (auth)

  4. Neutron induced fission of U isotopes up to 100 MeV

    International Nuclear Information System (INIS)

    Lestone, J.P.; Gavron, A.

    1993-01-01

    We have developed a statistical model description of the neutron induced fission of U isotopes using densities of intrinsic states and spin cut off parameters obtained directly from appropriate Nilsson model single particle levels. The first chance fission cross sections are well reproduced when the rotational contributions to the nuclear level densities are taken into account. In order to fit the U(n,f) cross sections above the threshold of second chance fission, we need to: (1) assume that the triaxial level density enhancement is washed out at an excitation energy of ∼7 MeV above the triaxial barriers with a width of ∼1 MeV, implying a γ deformation for the first barriers of 10 degree < γ < 20 degree; and (2) include pre-equilibrium particle emission in the calculations. Above an incoming neutron kinetic energy of ∼17 MeV our statistical model U(n,f) cross sections increasingly overestimate the experimental data when so called ''good'' optical model potentials are used to calculate the compound nucleus formation cross sections. This is not surprising since at these high energies little data exists on the scattering of neutrons to help guide the choice of optical model parameters. A satisfactory reproduction of all the available U(n,f) cross sections above 17 MeV is obtained by a simple scaling of our calculated compound nucleus formation cross sections. This scaling factor falls from 1.0 at 17 MeV to 0.82 at 100 MeV

  5. Scintillating-fiber imaging detector for 14-MeV neutrons

    International Nuclear Information System (INIS)

    Ress, D.; Lerche, R.A.; Ellis, R.J.; Heaton, G.W.; Nelson, M.B.; Mant, G.; Lehr, D.E.

    1994-01-01

    The authors have created a detector to image the neutrons emitted by imploded inertial-confinement fusion targets. The 14-MeV neutrons, which are produced by deuterium-tritium fusion events in the target, pass through an aperture to create an image on the detector. The neutron radiation is converted to blue light (430 nm) with a 20-cm-square array of plastic scintillating fibers. Each fiber is 10-cm long with a 1-mm-square cross section; approximately 35-thousand fibers make up the array. The resulting blue-light image is reduced and amplified by a sequence of fiber-optic tapers and image intensifiers, then acquired by a CCD camera. The fiber-optic readout system was tested optically for overall throughput the resolution. The authors plan to characterize the scintillator array reusing an ion-beam neutron source as well as DT-fusion neutrons emitted by inertial confinement targets. Characterization experiments will measure the light-production efficiency, spatial resolution, and neutron scattering within the detector. Several neutron images of laser-fusion targets have been obtained with the detector. Several neutron images of laser-fusion targets have been obtained with the detector. They describe the detector and their characterization methods, present characterization results, and give examples of the neutron images

  6. Observations on late effects in mice exposed to 400 MeV neutrons

    CERN Document Server

    Covelli, V; Bassani, B; Baarli, Johan; Bianchi, M; Metalli, P; Covelli, V; Di Paola, M; Bassani, B; Baarli, J no 2; Bianchi, M no 2; Metalli, P

    1976-01-01

    Life-long observations on mortality and pathology at death were carried out on groups of mice irradiated with 250 kV X-rays or exposed to a 400 MeV neutron beam, both directly and after attenuation corresponding to the maximum dose build-up region, at comparable dose-rates. Doses up to 84 rad of 400 MeV neutrons and up to 200 rad of X-rays showed no effect on the longevity of the animals, which suggests an upper limit to the r.b.e. for life-shortening of approximately 2·5. Similar conclusions were drawn from the data on all types of leukemias. For all other neoplasms, the age-specific death-rate showed a similar shortening of the latency times for groups of mice irradiated with 0–84 rad of 400 MeV direct neutrons and 0–400 rad of X-rays, also suggesting an upper limit to the r.b.e. slightly higher than that previously indicated for life-shortening. No definite effect was observed after exposure to the attenuated neutron beam at the doses used in these experiments.

  7. Exclusive data-based modeling of neutron-nuclear reactions below 20 MeV

    Science.gov (United States)

    Savin, Dmitry; Kosov, Mikhail

    2017-09-01

    We are developing CHIPS-TPT physics library for exclusive simulation of neutron-nuclear reactions below 20 MeV. Exclusive modeling reproduces each separate scattering and thus requires conservation of energy, momentum and quantum numbers in each reaction. Inclusive modeling reproduces only selected values while averaging over the others and imposes no such constraints. Therefore the exclusive modeling allows to simulate additional quantities like secondary particle correlations and gamma-lines broadening and avoid artificial fluctuations. CHIPS-TPT is based on the formerly included in Geant4 CHIPS library, which follows the exclusive approach, and extends it to incident neutrons with the energy below 20 MeV. The NeutronHP model for neutrons below 20 MeV included in Geant4 follows the inclusive approach like the well known MCNP code. Unfortunately, the available data in this energy region is mostly presented in ENDF-6 format and semi-inclusive. Imposing additional constraints on secondary particles complicates modeling but also allows to detect inconsistencies in the input data and to avoid errors that may remain unnoticed in inclusive modeling.

  8. Evaluating the 239Pu Prompt Fission Neutron Spectrum Induced by Thermal to 30 MeV Neutrons

    Directory of Open Access Journals (Sweden)

    Neudecker D.

    2016-01-01

    Full Text Available We present a new evaluation of the 239Pu prompt fission neutron spectrum (PFNS induced by thermal to 30 MeV neutrons. Compared to the ENDF/B-VII.1 evaluation, this one includes recently published experimental data as well as an improved and extended model description to predict PFNS. For instance, the pre-equilibrium neutron emission component to the PFNS is considered and the incident energy dependence of model parameters is parametrized more realistically. Experimental and model parameter uncertainties and covariances are estimated in detail. Also, evaluated covariances are provided between all PFNS at different incident neutron energies. Selected evaluation results and first benchmark calculations using this evaluation are briefly discussed.

  9. Use of 13.5-MeV neutrons for protein determination in grain crops

    International Nuclear Information System (INIS)

    Barit, I.A.; Kuz'min, L.E.; Makarov, S.A.; Vozhzhov, V.F.; Pronman, I.M.

    1989-01-01

    One of the main objectives of the Food Supply Program, i.e., that of improving the quality of crop production, is bound up intimately with the intensification of work on the selection and genetics of high-protein grain and legume crops. High-protein stains cannot be isolated without the proper analytical service for mass testing of the nitrogen content in the grain, which is one of the main elements of protein. The neutron-activation method of nitrogen determination is based on the use of the 14 N(n, 2n) 13 N nuclear reaction (E th = 11.3 MeV) with an average neutron energy of ∼14.5 MeV. In this work the authors consider a new variant of the neutron-activation method of determining nitrogen in grain and legume crops. The method is based on the use of monoenergetic neutrons with an energy of ∼13.5 MeV, generated in relatively thin titanium-tritium targets by a mass-separated deuteron beam from neutron generators operating at 150-300 kV, in order to eliminate the interference of the reaction 39 K(n, 2n) 38 K (E thr = 13.4 MeV). The present method has been used to determine the protein content (mass %) in different grains and legumes at the All-Union Selection-Genetic Institute of the Lenin Academy of Agricultural Sciences. The correctness of the analysis was checked by comparison with the data of chemical analysis. The discrepancy between the results of the two methods does not exceed 3%, which is within the limits of the error of measurement of Δ and K s.r

  10. Monte Carlo calculations of energy and angular distributions of transmitted and backscattered neutrons of 15 MeV incident energy

    International Nuclear Information System (INIS)

    Gaber, M.; Faied, A.

    1994-01-01

    The Monte Carlo technique was used to generate both energy and angular distributions of transmitted and backscattered neutrons incident on infinite graphite slabs of thicknesses ranging from 1-90 cm. Point isotropic and parallel beams of 15 MeV neutrons were used. A computer program was developed to simulate collisions by fast neutrons. (author)

  11. Theoretical model application to the evaluation of fission neutron data up to 20 MeV incidence energy

    International Nuclear Information System (INIS)

    Ruben, A.; Maerten, H.; Seeliger, D.

    1990-01-01

    A complex statistical theory of fission neutron emission combined with a phenomenological fission model has been used to calculate fission neutron data for 238 U. Obtained neutron multiplicities and energy spectra as well as average fragment energies for incidence energies from threshold to 20 MeV (including multiple-chance fission) are compared with traditional data representations. (author). 19 refs, 6 figs

  12. Neutron-photon multigroup cross sections for neutron energies less than or equal to400 MeV. Revision 1

    International Nuclear Information System (INIS)

    Alsmiller, R.G. Jr.; Barnes, J.M.; Drischler, J.D.

    1986-02-01

    Multigroup cross sections (66 neutron groups and 22 photon groups) are described for neutron energies from thermal to 400 MeV. The elements considered are hydrogen, 10 B, 11 B, carbon, nitrogen, oxygen, sodium, magnesium, aluminum, silicon, sulfur, potassium, calcium, chromium, iron, nickel, tungsten, and lead. The cross section data presented are a revision of similar data presented previously. In the case of iron, transport calculations using the earlier and the revised cross sections are presented and compared, and significant differences are found. The revised cross sections are available from the Radiation Shielding information Center of the Oak Ridge National Laboratory. 32 refs., 5 figs., 3 tabs

  13. Fast neutron (14.5 MeV) radiography: a comparative study

    International Nuclear Information System (INIS)

    Klann, R.T.

    1996-01-01

    Fast neutron (14.5 MeV) radiography is a type of non-destructive analysis tool that offers its own benefits and drawbacks. Because cross-sections vary with energy, a different range of materials can be examined with fast neutrons than can be studied with thermal neutrons, epithermal neutrons, or x-rays. This paper details these differences through a comparative study of fast neutron radiography to the other types of radiography available. The most obvious difference among the different types of radiography is in the penetrability of the sources. Fast neutrons can probe much deeper and can therefore obtain details of the internals of thick objects. Good images have been obtained through as much as 15 cm of steel, 10 cm of water, and 15 cm of borated polyethylene. In addition, some objects were identifiable through as much as 25 cm of water or 30 cm of borated polyethylene. The most notable benefit of fast neutron radiography is in the types of materials that can be tested. Fast neutron radiography can view through materials that simply cannot be viewed by X rays, thermal neutrons, or epithermal neutrons due to the high cross-sections or linear attenuation coefficients involved. Cadmium was totally transparent to the fast neutron source. Fast neutron radiography is not without drawbacks. The most pronounced drawback has been in the quality of radiograph produced. The image resolution is only about 0.8 mm for a 1.25 cm thick object, whereas, other forms of radiography have much better resolution

  14. Integral activation experiment of fusion reactor materials with d-Li neutrons up to 55 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Maekawa, Fujio; Ikeda, Yujiro [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment; Moellendorff, Ulrich von [Forschungszentrum Karlsruhe, Karlsruhe (Germany); Wada, Masayuki [Business Automation Co., Ltd., Tokyo (Japan)

    2000-03-01

    An integral activation experiment of fusion reactor materials with a deuteron-lithium neutron source was performed. Since the maximum energy of neutrons produced was 55 MeV, the experiment with associated analysis was one of the first attempts for extending the energy range beyond 20 MeV. The following keywords represent the present study: d-Li neutrons, 55 MeV, dosimetry, SAND-II, spectrum adjustment, LA-150, MCNP, McDeLi, IFMIF, fusion reactor materials, integral activation experiment, low-activation, F82H, vanadium-alloy, IEAF, ALARA, and sequential charged particle reaction. (author)

  15. Measurement of prompt neutron spectra from the "2"3"9Pu(n, f ) fission reaction for incident neutron energies from 1 to 200 MeV

    International Nuclear Information System (INIS)

    Chatillon, A.; Belier, G.; Granier, T.; Laurent, B.; Morillon, B.; Taieb, J.; Haight, R.C.; Devlin, M.; Nelson, R.O.; Noda, R.S.; O'Donnell, J.M.

    2014-01-01

    Prompt fission neutron spectra in the neutron-induced fission of "2"3"9Pu have been measured for incident neutron energies from 1 to 200 MeV at the Los Alamos Neutron Science Center. Mean energies deduced from the prompt fission neutron spectra (PFNS) lead to the observation of the opening of the second chance fission at 7 MeV and to indications for the openings of fission channels of third and fourth chances. Moreover, the general trend of the measured PFNS is well reproduced by the different models. The comparison between data and models presents, however, two discrepancies. First, the prompt neutron mean energy seems constant for neutron energy, at least up to 7 MeV, whereas in the theoretical calculations it is continuously increasing. Second, data disagree with models on the shape of the high energy part of the PFNS, where our data suggest a softer spectrum than the predictions. (authors)

  16. Beam plasma 14 MeV neutron source for fusion materials development

    International Nuclear Information System (INIS)

    Ravenscroft, D.; Bulmer, D.; Coensgen, F.; Doggett, J.; Molvik, A.; Souza, P.; Summers, L.; Williamson, V.

    1991-09-01

    The conceptual engineering design and expected performance for a 14 MeV DT neutron source is detailed. The source would provide an intense neutron flux for accelerated testing of fusion reactor materials. The 150-keV neutral beams inject energetic deuterium atoms, that ionize, are trapped, then react with a warm (200 eV), dense tritium target plasma. This produces a neutron source strength of 3.6 x 10 17 n/sec for a neutron power density at the plasma edge of 5--10 MW/m 2 . This is several times the ∼2 MW/m 2 anticipated at the first wall of fusion reactors. This high flux provides accelerated end-of-life tests of 1- to 2-year duration, thus making materials development possible. The modular design of the source and the facilities are described

  17. The new JET 2.5-MeV neutron time-of-flight spectrometer

    International Nuclear Information System (INIS)

    Elevant, T.; Belle, P.v.; Grosshoeg, G.; Hoek, M.; Jarvis, O.N.; Olsson, M.; Sadler, G.

    1992-01-01

    A major upgrade of the JET 2.5-MeV neutron time-of-flight spectrometer has been completed. The improvement has permitted ion temperature measurements for Maxwellian deuterium plasmas with T i >4 keV to be obtained in 0.5-s intervals. By combining observations of neutron and x-ray energy spectra with studies of γ-ray emission from reactions between fast deuterons and impurities, the effects of ICRF heating on the deuterium energy distribution have been studied. The time evolution of neutron energy spectra from deuterium-beam heated deuterium plasmas is illustrated and a method for evaluating the ion temperature from such sequences is indicated. Furthermore, the spectrometer has shown stable performance during high neutron fluxes

  18. Elastic neutron scattering studies at 96 MeV for transmutation.

    Science.gov (United States)

    Osterlund, M; Blomgren, J; Hayashi, M; Mermod, P; Nilsson, L; Pomp, S; Ohrn, A; Prokofiev, A V; Tippawan, U

    2007-01-01

    Elastic neutron scattering from (12)C, (14)N, (16)O, (28)Si, (40)Ca, (56)Fe, (89)Y and (208)Pb has been studied at 96 MeV in the10-70 degrees interval, using the SCANDAL (SCAttered Nucleon Detection AssembLy) facility. The results for (12)C and (208)Pb have recently been published, while the data on the other nuclei are under analysis. The achieved energy resolution, 3.7 MeV, is about an order of magnitude better than for any previous experiment above 65 MeV incident energy. A novel method for normalisation of the absolute scale of the cross section has been used. The estimated normalisation uncertainty, 3%, is unprecedented for a neutron-induced differential cross section measurement on a nuclear target. Elastic neutron scattering is of utmost importance for a vast number of applications. Besides its fundamental importance as a laboratory for tests of isospin dependence in the nucleon-nucleon, and nucleon-nucleus, interaction, knowledge of the optical potentials derived from elastic scattering come into play in virtually every application where a detailed understanding of nuclear processes is important. Applications for these measurements are dose effects due to fast neutrons, including fast neutron therapy, as well as nuclear waste incineration and single event upsets in electronics. The results at light nuclei of medical relevance ((12)C, (14)N and (16)O) are presented separately. In the present contribution, results on the heavier nuclei are presented, among which several are of relevance to shielding of fast neutrons.

  19. The sensitivity of LaBr{sub 3}:Ce scintillation detectors to low energy neutrons: Measurement and Monte Carlo simulation

    Energy Technology Data Exchange (ETDEWEB)

    Tain, J.L., E-mail: tain@ific.uv.es [Instituto de Física Corpuscular, CSIC–Universidad de Valencia, Apdo. Correos 22085, E-46071 Valencia (Spain); Agramunt, J.; Algora, A. [Instituto de Física Corpuscular, CSIC–Universidad de Valencia, Apdo. Correos 22085, E-46071 Valencia (Spain); Aprahamian, A. [University of Notre Dame, Department of Physics, IN 46556, Notre Dame (United States); Cano-Ott, D. [Centro de Investigaciones Energéticas Medioambientales y Tecnológicas, E-28040 Madrid (Spain); Fraile, L.M. [Universidad Complutense, Grupo de Fisica Nuclear, CEI Moncloa, E-28040 Madrid (Spain); Guerrero, C. [CERN, Geneva (Switzerland); Jordan, M.D. [Instituto de Física Corpuscular, CSIC–Universidad de Valencia, Apdo. Correos 22085, E-46071 Valencia (Spain); Mach, H. [University of Notre Dame, Department of Physics, IN 46556, Notre Dame (United States); Universidad Complutense, Grupo de Fisica Nuclear, CEI Moncloa, E-28040 Madrid (Spain); Martinez, T.; Mendoza, E. [Centro de Investigaciones Energéticas Medioambientales y Tecnológicas, E-28040 Madrid (Spain); Mosconi, M.; Nolte, R. [Physikalisch-Technische Bundesanstalt, D-38116 Braunschweig (Germany)

    2015-02-21

    The neutron sensitivity of a cylindrical ⊘1.5 in.×1.5 in. LaBr{sub 3}:Ce scintillation detector was measured using quasi-monoenergetic neutron beams in the energy range from 40 keV to 2.5 MeV. In this energy range the detector is sensitive to γ-rays generated in neutron inelastic and capture processes. The experimental energy response was compared with Monte Carlo simulations performed with the Geant4 simulation toolkit using the so-called High Precision Neutron Models. These models rely on relevant information stored in evaluated nuclear data libraries. The performance of the Geant4 Neutron Data Library as well as several standard nuclear data libraries was investigated. In the latter case this was made possible by the use of a conversion tool that allowed the direct use of the data from other libraries in Geant4. Overall it was found that there was good agreement with experiment for some of the neutron data bases like ENDF/B-VII.0 or JENDL-3.3 but not with the others such as ENDF/B-VI.8 or JEFF-3.1.

  20. Utilization of new 150-MeV neutron and proton evaluations in MCNP

    International Nuclear Information System (INIS)

    Little, R.C.; Frankle, S.C.; Hughes, H.G. III; Prael, R.E.

    1997-01-01

    MCNP trademark and LAHET trademark are two of the codes included in the LARAMIE (Los Alamos Radiation Modeling Interactive Environment) code system. Both MCNP and LAHET are three-dimensional continuous-energy Monte Carlo radiation transport codes. The capabilities of MCNP and LAHET are currently being merged into one code for the Accelerator Production of Tritium (APT) program at Los Alamos National Laboratory. Concurrently, a significant effort is underway to improve the accuracy of the physics in the merged code. In particular, full nuclear-data evaluations (in ENDF6 format) for many materials of importance to APT are being produced for incident neutrons and protons up to an energy of 150-MeV. After processing, cross-section tables based on these new evaluations will be available for use fin the merged code. In order to utilize these new cross-section tables, significant enhancements are required for the merged code. Neutron cross-section tables for MCNP currently specify emission data for neutrons and photons only; the new evaluations also include complete neutron-induced data for protons, deuterons, tritons, and alphas. In addition, no provision in either MCNP or LAHET currently exists for the use of incident charged-particle tables other than for electrons. To accommodate the new neutron-induced data, it was first necessary to expand the format definition of an MCNP neutron cross-section table. The authors have prepared a 150-MeV neutron cross-section library in this expanded format for 15 nuclides. Modifications to MCNP have been implemented so that this expanded neutron library can be utilized

  1. Investigation of the neutron-proton-interaction in the energy range from 20 to 50 MEV

    International Nuclear Information System (INIS)

    Wilczynski, J.

    1984-07-01

    In the framework of the investigation of the isospin singlet part of the nucleon-nucleon-interaction in the energy range below 100 MeV two experiments were conducted, which were selected by sensitivity calculations. At the Karlsruhe polarized neutron facility POLKA the analyzing powers Asub(y) and Asub(yy) of the elastic n vector-p- and n vector-p vector-scattering were measured in the energy range from 20 to 50 MeV. The results of this epxeriment are compared to older data. In the energy range from 20 to 50 MeV the new data were analyzed together with other selected data of the nucleon-nucleon-system in phase shift analyses. The knowledge of the isospin singlet phase shifts 1 P 1 and 3 D 3 was improved by the new data. (orig./HSI) [de

  2. Neutron-deuteron analyzing power data at 19.0 MeV

    International Nuclear Information System (INIS)

    Weisel, G. J.; Tornow, W.; Crowe, B. J. III; Crowell, A. S.; Esterline, J. H.; Howell, C. R.; Kelley, J. H.; Macri, R. A.; Pedroni, R. S.; Walter, R. L.; Witala, H.

    2010-01-01

    Measurements of neutron-deuteron (n-d) analyzing power A y (θ) at E n =19.0 MeV are reported at 16 angles from θ c.m. =46.7 to 152.0 deg. The objective of the experiment is to better characterize the discrepancies between n-d data and the predictions of three-nucleon calculations for neutron energies above 16.0 MeV. The experiment used a shielded neutron source, which produced polarized neutrons via the 2 H(d-vector,n-vector) 3 He reaction, a deuterated liquid scintillator center detector (CD) and liquid-scintillator neutron side detectors. A coincidence between the CD and the side detectors isolated the elastic-scattering events. The CD pulse height spectrum associated with each side detector was sorted by using pulse-shape discrimination, time-of-flight techniques, and by removing accidental coincidences. A Monte Carlo computer simulation of the experiment accounted for effects due to finite geometry, multiple scattering, and CD edge effects. The resulting high-precision data (with absolute uncertainties ranging from 0.0022 to 0.0132) have a somewhat lower discrepancy with the predictions of three-body calculations, as compared to those found at lower energies.

  3. Cross section measurement for (n,n{alpha}) reactions by 14 MeV neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Kasugai, Y.; Ikeda, Y.; Uno, Y. [Japan Atomic Energy Research Inst., Naka, Ibaraki (Japan). Naka Fusion Research Establishment; Yamamoto, H.; Kawade, K.

    1997-03-01

    Nine (n,n{alpha}) cross sections for (n,n{alpha}) reactions induced by 13.5-14.9 MeV neutrons were measured for {sup 51}V, {sup 65}Cu, {sup 71}Ga, {sup 76}Ge, {sup 87}Rb, {sup 91}Zr, {sup 93}Nb, {sup 96}Zr and {sup 109}Ag isotopes by using Fusion Neutronics Source (FNS) at JAERI. The reactions for 91Zr and 96Zr were measured for the first time. The evaluated data of JENDL-3 and ENDF/B-VI were compared with the present data. Some of the evaluated values are much different from our data by a factor more than ten. (author)

  4. Lithium Blanket Module dosimetry measurements at the LOTUS 14-MeV neutron source facility

    International Nuclear Information System (INIS)

    Tsang, F.Y.; Leo, W.R.; Sahraoui, C.; Wuthrich, S.; Harker, Y.D.

    1986-01-01

    This paper describes the measurements and results of the dosimeter material reaction rates inside the Lithium Blanket Module (LBM) after irradiation by the LOTUS 14-MeV neutron source at the Ecole Polytechnique Federale de Lausanne. The measurement program has been designed to utilize sets of passive dosimeter materials in the form of foils and wires. The dosimetry materials reaction thresholds and interaction response ranges chosen for this series of measurements encompass the entire neutron spectra along the full length of the LBM fuel rods

  5. The construction of a facility for 14 Mev neutron activation analysis of oxygen in aluminium

    International Nuclear Information System (INIS)

    Bjoernstad, T.; Alstad, J.

    1984-02-01

    The article describes the construction and performance of a facility for 14 MeV neutron activation analysis, mainly for oxygen in aluminium, at the University of Oslo. It consists of a sealed tube neutron generator, a biaxial rotation system for samples in irradiation position, a mechanism for automatic separation of sample and container, and appropriate detectors and counting electronics. Especially considered are the procedures for sample preparation and packing, standardization, optimization of the energy range for integration and optimization of the irradiation, decay and counting times. The applicability of the facility is exemplified by analytical results from comparative investigations in different laboratories using different methods. (Auth.)

  6. Quality factor calculations for neutron spectra below 4 MeV

    International Nuclear Information System (INIS)

    Borak, T.B.; Stinchcomb, T.G.

    1979-01-01

    A method is described for computing the distribution of absorbed dose, D(L), as a function of linear energy transfer, L, for any neutron spectrum with energies below 4 MeV. The results are used to determine the average quality factor for two distinctly different neutron spectra using the ICRP recommended values of the quality factor, Q(L). A comparison is made between the calculations and measurements of D(L) using a spherical tissue equivalent proportional counter. Heavy ion recoil contributions to the average quality factor are examined in detail. (author)

  7. Gamma-ray emission spectra from spheres with 14 MeV neutron source

    International Nuclear Information System (INIS)

    Yamamoto, Junji; Kanaoka, Takeshi; Murata, Isao; Takahashi, Akito; Sumita, Kenji

    1989-01-01

    Energy spectra of neutron-induced gamma-rays emitted from spherical samples were measured using a 14 MeV neutron source. The samples in use were LiF, Teflon:(CF 2 ) n , Si, Cr, Mn, Co, Cu, Nb, Mo, W and Pb. A diameter of the sphere was either 40 or 60 cm. The gamma-ray energy in the emission spectra covered the range from 500 keV to 10 MeV. Measured spectra were compared with transport calculations using the nuclear data files of JENDL-3T and ENDF/B-IV. The agreements between the measurements and the JENDL-3T calculations were good in the emission spectra for the low energy gamma-rays from inelastic scattering. (author)

  8. Tooth enamel dosimetric response to 2.8 MeV neutrons

    Science.gov (United States)

    Fattibene, P.; Angelone, M.; Pillon, M.; De Coste, V.

    2003-03-01

    Tooth enamel dosimetry, based on electron paramagnetic resonance (EPR) spectroscopy, is recognized as a powerful method for individual retrospective dose assessment. The method is mainly used for individual dose reconstruction in the epidemiological studies aimed at the radiation risk analysis. The study of the sensitivity of tooth enamel as a function of radiation quality is one of the main goals of the research in this field. In the present work, tooth enamel dose response in a monoenergetic neutron flux of 2.8 MeV, generated by the D-D reaction, was studied for in air and in phantom irradiations of enamel samples and of whole teeth. EPR measurements were complemented by Monte Carlo calculation and by gamma dose discrimination obtained with thermoluminescent and Geiger-Muller tube measurements. The 2.8 MeV neutrons to 60Co relative sensitivity was 0.33±0.08.

  9. Tooth enamel dosimetric response to 2.8 MeV neutrons

    International Nuclear Information System (INIS)

    Fattibene, P.; Angelone, M.; Pillon, M.; De Coste, V.

    2003-01-01

    Tooth enamel dosimetry, based on electron paramagnetic resonance (EPR) spectroscopy, is recognized as a powerful method for individual retrospective dose assessment. The method is mainly used for individual dose reconstruction in the epidemiological studies aimed at the radiation risk analysis. The study of the sensitivity of tooth enamel as a function of radiation quality is one of the main goals of the research in this field. In the present work, tooth enamel dose response in a monoenergetic neutron flux of 2.8 MeV, generated by the D-D reaction, was studied for in air and in phantom irradiations of enamel samples and of whole teeth. EPR measurements were complemented by Monte Carlo calculation and by gamma dose discrimination obtained with thermoluminescent and Geiger-Muller tube measurements. The 2.8 MeV neutrons to 60 Co relative sensitivity was 0.33±0.08

  10. Sputtering of vanadium and niobium under 14.1 MeV neutron impact

    International Nuclear Information System (INIS)

    Kaminsky, M.; Das, S.K.

    1976-01-01

    The recent studies of particle emission from cold-rolled and annealed niobium under 14.1-MeV neutron impact were extended to a heavily etched, polycrystalline niobium surface and to cold worked vanadium surfaces with different degrees of microstructure. The type and amount of material released and deposited on collector surfaces facing the irradiated targets were determined by three analytical techniques. Two types of deposits were found for certain types of surfaces--one in the form of chunks; the other as a fractional atom layer covering the surface. The chunks vary significantly in size. The small number of chunks observed suggests that the ejection of chunks is a relatively rare event in comparison to the total number of primary knock-on events produced by 14-MeV neutrons in near surface regions. Estimates of the total sputtering yield based on the chunk deposits and on the fractional atom layer deposit will be given

  11. Neutron induced alpha production from carbon between 18 and 22 MeV

    International Nuclear Information System (INIS)

    Stevens, A.P.

    1976-10-01

    Cross sections for neutron induced alpha production in carbon were measured at seventeen energies between 18 and 22 MeV, using a deuterated anthracene crystal as both target and detector. Pulse shape discrimination was employed to separate the alphas and elastically scattered deuterons from the other reaction products. Published (n,d) elastic scattering data were used as a standard to obtain the alpha production cross sections. Comparison with available measurements shows good agreement

  12. Simultaneous determination of nitrogen and phosphorus in cereals using 14 MeV Neutron Activation Analysis

    International Nuclear Information System (INIS)

    Bejarano, R.

    1992-01-01

    A method using 14 MeV neutron activation analysis was developed form non-destructive simultaneous determination of N and P in cereals. The samples were irradiated 5 min. after 0,5 min. decay time. The induced activities were measured using gamma spectrometry with Nal(Tl) well type detector. The accuracy, precision and detection limits obtained are discussed as well as the analytical results for different types of cereals. (Author) 10 refs., 8 tab., 1 fig

  13. Calculated neutron spectrum from 800-MeV protons incident on a copper beam stop

    International Nuclear Information System (INIS)

    Perry, D.G.

    1975-10-01

    A Monte Carlo calculation was performed to obtain the neutron spectrum generated by 800-MeV protons incident on the LAMPF main copper beam stop. The total flux is calculated to be of the order of 10 13 n/cm 2 -sec-mA at full-beam intensity of 1 mA, with flux spectra calculated for angles of 20 0 , 30 0 , 60 0 , 90 0 , 120 0 , and 150 0 . (auth)

  14. Determination of phosphorus and potassium in sugar cane leaves by 14 MeV neutrons

    International Nuclear Information System (INIS)

    Diaz, R.A.; Nagy, A.Z.; Bakos, L.; Soria, J.C.

    1979-04-01

    The possibilities of N, P, K evaluation in samples of sugar cane leaves were discussed. A method for determining P and K content in this samples by 14 MeV neutron activation analysis is described. Corrections for K and Si were taken into account. The limit of detection for P was 0.1 mg and for K it was 4 mg. The precision for P and K was 10% in agreement with the values given by other authors. (author)

  15. Use of the SPIRAL 2 facility for material irradiations with 14 MeV energy neutrons

    International Nuclear Information System (INIS)

    Mosnier, A.; Ridikas, D.; Ledoux, X.; Pellemoine, F.; Anne, R.; Huguet, Y.; Lipa, M.; Magaud, P.; Marbach, G.; Saint-Laurent, M.G.; Villari, A.C.C.

    2005-01-01

    The primary goal of an irradiation facility for fusion applications will be to generate a material irradiation database for the design, construction, licensing and safe operation of a fusion demonstration power station (e.g., DEMO). This will be achieved through testing and qualifying material performance under neutron irradiation that simulates service up to the full lifetime anticipated in the power plant. Preliminary investigations of 14 MeV neutron effects on different kinds of fusion material could be assessed by the SPIRAL 2 Project at GANIL (Caen, France), aiming at rare isotope beams production for nuclear physics research with first beams expected by 2009. In SPIRAL 2, a deuteron beam of 5 mA and 40 MeV interacts with a rotating carbon disk producing high-energy neutrons (in the range between 1 and 40 MeV) via C (d, xn) reactions. Then, the facility could be used for 3-4 months y -1 for material irradiation purposes. This would correspond to damage rates in the order of 1-2 dpa y -1 (in Fe) in a volume of ∼10 cm 3 . Therefore, the use of miniaturized specimens will be essential in order to effectively utilize the available irradiation volume in SPIRAL 2. Sample package irradiation temperature would be in the range of 250-1000 deg. C. The irradiation level of 1-2 dpa y -1 with 14 MeV neutrons (average energy) may be interesting for micro-structural and metallurgical investigations (e.g., mini-traction, small punch tests, etc.) and possibly for the understanding of specimen size/geometric effects of critical material properties. Due to the small test cell volume, sample in situ experiments are not foreseen. However, sample packages would be, if required, available each month after transfer in a special hot cell on-site

  16. Activation analysis course experiments with a 14-MeV neutron generator

    International Nuclear Information System (INIS)

    Miller, D.A.; Miller, G.E.

    1976-01-01

    The use of a 14 MeV neutron generator system in the radiochemistry teaching program of the Chemistry Department of the University of California at Irvine is described. Several different types of experiment are outlined to indicate the broad applicability of such a system to an instructional program in Chemistry. The program has encompassed instruction of undergraduates, graduate students and a Summer Institute Workshop for College Professors

  17. In vitro activation of bone with 14 MeV neutrons

    International Nuclear Information System (INIS)

    Holmberg, P.; Hyvoenen, M.; Tarvainen, M.

    1978-01-01

    Samples of compact bone, bone marrow and spongiosa of cow femur have been irradiated in vitro with 14 MeV neutrons. The Ca/P ratio for compact bone was found to be 2.16+-0.24. The suitability of using 14 MeV neutrons and the 31 P(n, α) 28 Al reaction for studying the bone mineral composition in vitro is discussed. It was demonstrated that 14 MeV neutrons can be used for the determination of calcium and phosphorus in bone with the aid of the 44 Ca(n, p) 44 K and 31 P(n, α) 28 Al reactions, respectively. As the Ca/P ratio for compact bone is known, the calcium content can be deduced indirectly from a determination of the phosphorus. This method has the advantage of not requiring moderator materials, as in the case when the 48 Ca(n, γ) 49 Ca reaction is employed. The half-life of the 28 Al activity is short (T=2.243 m) so that only short irradiation times are necessary. (T.G.)

  18. Spectrum of neutrons leaking from an iron sphere with a central 14 MeV neutron source

    International Nuclear Information System (INIS)

    Borisov, A.A.; Zagryadskij, V.A.; Chuvilin, D.Yu.; Kralik, M.; Pulpan, J.; Tichy, M.

    1991-01-01

    Following a review of the present state of nuclear data requisite for the calculation of the transport of 14 MeV neutrons through iron of natural isotopic composition, the results are given of the calculation of the energy spectrum of such neutrons after their passage through an iron sphere 240 mm o.d. and 90 mm i.d., the neutron source being accommodated in the centre of the sphere. The calculations were made using the one-dimensional code BLANK working with the nuclear data libraries ENDL-75, ENDL-83, ENDL/B-IV, JENDL-2 and BROND, and using the three-dimensional code BRAND with the library ENDL-78. The calculated spectra were compared with the experimental spectrum measured at a distance of 3 m from the sphere by means of an NE-213 scintillator, which records reflected protons. The reflected proton spectrum was processed by the matrix method (program FORIST), and the result was normalized to one neutron emitted by the source, as were the calculated spectra. The comparison demonstrates that the experiment is best fitted by the spectrum calculated by using the library JENDL-2, where the integrals of the observed and calculated spectra over the 1-15 MeV range differ as little as approximately 10%. (author). 3 figs., 5 tabs., 16 refs

  19. Neutron leakage from Pb and Bc spherical shells with 14 MeV central neutron source

    International Nuclear Information System (INIS)

    Antonov, S.; Daskalov, G.; Ilieva, K.; Jordanova, J.; Prodanova, R.; Zagryadskij, V.A.; Novikov, V.M.; Chuvilin, D.Yu.

    1988-01-01

    Results of measuring neutron leakage from spherical shells of different thickness, made of Pb and Be with a point neutron source in the sphere centrum are presented. The experiment results are compared to calculations according to different programs using data of various nuclear data libraies. The comparison has shown that all the calculations understate the neutron leakage from Pb assmebly. 9 refs.; 2 tabs

  20. Design of 6 Mev linear accelerator based pulsed thermal neutron source: FLUKA simulation and experiment

    Energy Technology Data Exchange (ETDEWEB)

    Patil, B.J., E-mail: bjp@physics.unipune.ac.in [Department of Physics, University of Pune, Pune 411 007 (India); Chavan, S.T.; Pethe, S.N.; Krishnan, R. [SAMEER, IIT Powai Campus, Mumbai 400 076 (India); Bhoraskar, V.N. [Department of Physics, University of Pune, Pune 411 007 (India); Dhole, S.D., E-mail: sanjay@physics.unipune.ac.in [Department of Physics, University of Pune, Pune 411 007 (India)

    2012-01-15

    The 6 MeV LINAC based pulsed thermal neutron source has been designed for bulk materials analysis. The design was optimized by varying different parameters of the target and materials for each region using FLUKA code. The optimized design of thermal neutron source gives flux of 3 Multiplication-Sign 10{sup 6}ncm{sup -2}s{sup -1} with more than 80% of thermal neutrons and neutron to gamma ratio was 1 Multiplication-Sign 10{sup 4}ncm{sup -2}mR{sup -1}. The results of prototype experiment and simulation are found to be in good agreement with each other. - Highlights: Black-Right-Pointing-Pointer The optimized 6 eV linear accelerator based thermal neutron source using FLUKA simulation. Black-Right-Pointing-Pointer Beryllium as a photonuclear target and reflector, polyethylene as a filter and shield, graphite as a moderator. Black-Right-Pointing-Pointer Optimized pulsed thermal neutron source gives neutron flux of 3 Multiplication-Sign 10{sup 6} n cm{sup -2} s{sup -1}. Black-Right-Pointing-Pointer Results of the prototype experiment were compared with simulations and are found to be in good agreement. Black-Right-Pointing-Pointer This source can effectively be used for the study of bulk material analysis and activation products.

  1. SCANDAL -- A facility for elastic neutron scattering studies in the 50--130 MeV range

    International Nuclear Information System (INIS)

    Klug, J.; Blomgren, J.; Atac, A.; Bergenwall, B.; Dangtip, S.; Elmgren, K.; Johansson, C.; Olsson, N.; Prokofiev, A.V.; Rahm, J.; Oberstedt, A.; Tovesson, F.; Eudes, Ph.; Haddad, F.; Kerveno, M.; Kirchner, T.; Lebrun, C.; Stuttge, L.; Slypen, I.; Michel, R.; Neumann, S.; Herpers, U.

    2001-01-01

    A facility for detection of scattered neutrons in the energy interval 50--130 MeV, SCANDAL (SCAttered Nucleon Detection AssembLy), has recently been installed at the 20--180 MeV neutron beam facility of the The Svedberg Laboratory, Uppsala. It is primarily intended for studies of elastic neutron scattering, but can be used for the (n,p) and (n,d) reaction experiments as well. The performance of the spectrometer is illustrated in measurements of the (n,p) and (n,n) reactions on 1 H and 12 C. In addition, the neutron beam facility is described in some detail

  2. Neutron spectrum at 900 from 800 MeV (p,n) reactions on a Ta target

    International Nuclear Information System (INIS)

    Howe, S.D.; Lisowski, P.W.; King, N.S.P.; Russell, G.J.; Donnert, H.J.

    1979-01-01

    The neutron time-of-flight spectrum produced by a thick tantalum target bombarded by 800-MeV protons was measured at an angle of 90 0 . The data were taken at the Weapons Neutron Research facility by use of a cylindrical Ta target with a radius of 1.27 cm and a length of 15 cm. An NE-213 liquid scintillator was used to detect the neutrons over an energy range of 0.5 to 350 MeV. The neutron yield is presented and compared to a intranuclear-cascade/evaporation model prediction. 3 figures

  3. SCANDAL--a facility for elastic neutron scattering studies in the 50-130 MeV range

    CERN Document Server

    Klug, J; Atac, A; Bergenwall, B; Dangtip, S; Elmgren, K; Johansson, C; Olsson, N; Pomp, S; Prokofiev, A V; Rahm, J; Tippawan, U; Jonsson, O; Nilsson, L; Renberg, P U; Nadel-Turonski, P; Ringbom, A; Oberstedt, A; Tovesson, F; Blideanu, V; Le Brun, C; Lecolley, J F; Lecolley, F R; Louvel, M; Marie, N; Schweitzer, C; Varignon, C; Eudes, P; Haddad, F; Kerveno, M; Kirchner, T; Lebrun, C; Stuttgé, L; Slypen, I; Smirnov, A N; Michel, R; Neumann, S; Herpers, U

    2002-01-01

    A facility for detection of scattered neutrons in the energy interval 50-130 MeV, SCAttered Nucleon Detection AssembLy (SCANDAL), has recently been installed at the 20-180 MeV neutron beam facility of The Svedberg Laboratory, Uppsala. It is primarily intended for studies of elastic neutron scattering, but can be used for (n,p) and (n,d) reaction experiments as well. The performance of the spectrometer is illustrated in measurements of the (n,p) and (n,n) reactions on sup 1 H and sup 1 sup 2 C. In addition, the neutron beam facility is described in some detail.

  4. Single event upsets calculated from new ENDF/B-VI proton and neutron data up to 150 MeV

    International Nuclear Information System (INIS)

    Chadwick, M.B.

    1999-01-01

    Single-event upsets (SEU) in microelectronics are calculated from newly-developed silicon nuclear reaction recoil data that extend up to 150 MeV, for incident protons and neutrons. Calculated SEU cross sections are compared with measured data

  5. Analysis of oxygen content in steel by means of 14 MeV neutrons

    International Nuclear Information System (INIS)

    Chuang, L.S.; Wong, K.C.; Chiu, W.Y.

    1975-01-01

    A sealed-tube type 14 MeV neutron generator with maximum neutron output of 10 11 n/sec, incorporating a pneumatic sample transfer system of single-tube type and with a single rotation of the sample during neutron irradiation, is used to develop a method suitable for routine work in industrial applications. A pulse shape analyser system incorporating an organic scintillation detector is used for monitoring neutron flux level during the neutron irradiation of the sample. Polyethylene, of oxygen content 163 ppm determined by comparison with lucite, is used as the steel sample carrier. A 3 x 3 in. NaI(Tl) crystal is used with a single channel analyser to count the 6.1 and 7.1 MeV gamma rays emitted from 16 N as a result of the reaction 16 O(n,p) 16 N. As the present activation analysis makes use of the comparison method, a steel-mylar standard made of layered steel and mylar discs is prepared and a calibration curve constructed. A method of correcting the oxygen contribution in the polyethylene sample carrier is devised and the content of oxygen in the steel standard is determined. A survey of neutron flux distribution is also attempted and it is found that nearly symmetrical distribution of the flux, about the centre of the sample carrier which is placed with its axis in parallel to the plane of the disc-shaped target of the neutron-generating tube, is far from being flat. (Auth.)

  6. Reference neutron radiations. Part 1: Characteristics and methods of production

    International Nuclear Information System (INIS)

    2001-01-01

    ISO 8529 consists of the following parts, under the general title Reference neutron radiations: Part 1: Characteristics and methods of production; Part 2: Calibration fundamentals of radiation protection devices related to the basic quantities characterizing the radiation field; Part 3: Calibration of area and personal dosimeters and determination of response as a function of energy and angle of incidence. This Part 1. of ISO 8529 specifies the reference neutron radiations, in the energy range from thermal up to 20 MeV, for calibrating neutron-measuring devices used for radiation protection purposes and for determining their response as a function of neutron energy. Reference radiations are given for neutron fluence rates of up to 1x10 9 m 2 s-1 , corresponding, at a neutron energy of 1 MeV, to dose-equivalent rates of up to 100 mSv h -1 . This part of ISO 8529 is concerned only with the methods of producing and characterizing the neutron reference radiations. The procedures for applying these radiations for calibrations are described in ISO 8529-2 and ISO 8529-3. The reference radiations specified are the following: neutrons from radionuclide sources, including neutrons from sources in a moderator; neutrons produced by nuclear reactions with charged particles from accelerators; neutrons from reactors. In view of the methods of production and use of them, these reference radiations are divided, for the purposes of this part of ISO 8529, into the following two separate sections. In clause 4, radionuclide neutron sources with wide spectra are specified for the calibration of neutron measuring devices. These sources should be used by laboratories engaged in the routine calibration of neutron-measuring devices, the particular design of which has already been type tested. In clause 5, accelerator-produced monoenergetic neutrons and reactor-produced neutrons with wide or quasi monoenergetic spectra are specified for determining the response of neutron-measuring devices

  7. Production of a pulseable fission-like neutron flux using a monoenergetic 14 MeV neutron generator and a depleted uranium reflector

    Science.gov (United States)

    Koltick, D.; McConchie, S.; Sword, E.

    2008-04-01

    The design and performance of a pulseable neutron source utilizing a D-T neutron generator and a depleted uranium reflector are presented. Approximately half the generator's 14 MeV neutron flux is used to produce a fission-like neutron spectrum similar to 252Cf. For every 14 MeV neutron entering the reflector, more than one fission-like neutron is reflected back across the surface of the reflector. Because delayed neutron production is more than two orders of magnitude below the prompt neutron production, the source takes full advantage of the generator's pulsed mode capability. Applications include all elemental characterization systems using neutron-induced gamma-ray spectroscopy. The source simultaneously emits 14 MeV neutrons optimal to excite fast neutron-induced gamma-ray signals, such as from carbon and oxygen, and fission-like neutrons optimal to induce neutron capture gamma-ray signals, such as from hydrogen, nitrogen, and chlorine. Experiments were performed, which compare well to Monte Carlo simulations, showing that the uranium reflector enhances capture signals by up to a factor of 15 compared to the absence of a reflector.

  8. Neutron-deuteron analyzing power data at En=22.5 MeV

    Science.gov (United States)

    Weisel, G. J.; Tornow, W.; Crowell, A. S.; Esterline, J. H.; Hale, G. M.; Howell, C. R.; O'Malley, P. D.; Tompkins, J. R.; Witała, H.

    2014-05-01

    We present measurements of n-d analyzing power, Ay(θ), at En=22.5 MeV. The experiment uses a shielded neutron source which produced polarized neutrons via the 2H(d⃗,n⃗)3He reaction. It also uses a deuterated liquid-scintillator center detector and six pairs of liquid-scintillator neutron side detectors. Elastic neutron scattering events are identified by using time-of-flight techniques and by setting a window in the center detector pulse-height spectrum. The beam polarization is monitored by using a high-pressure helium gas cell and an additional pair of liquid-scintillator side detectors. The n-d Ay(θ) data were corrected for finite-geometry and multiple-scattering effects using a Monte Carlo simulation of the experiment. The 22.5-MeV data demonstrate that the three-nucleon analyzing power puzzle also exists at this energy. They show a significant discrepancy with predictions of high-precision nucleon-nucleon potentials alone or combined with Tucscon-Melbourne or Urbana IX three-nucleon forces, as well as currently available effective-field theory based potentials of next-to-next-to-next-to-leading order.

  9. Radiography studies with gamma rays produced by 14-MeV fusion neutrons

    International Nuclear Information System (INIS)

    Smith, D.L.; Ikeda, Yujiro; Uno, Yoshitomo

    1996-01-01

    Oxygen contained in pure water has been activated via the 16 O(n, p) 16 N reaction using 14-MeV neutrons produced at a neutron generator with the 3 H(d,n) 4 He source. Photons of 6.129 and 7.115 MeV, generated by the decay of 7.13-second 16 N, were then used to demonstrate the feasibility of employing highly penetrating, nearly monoenergetic gamma rays for radiography studies of thick, dense objects composed of elements with medium to relatively high atomic numbers. A simple radiography apparatus was constructed by circulating water continuously between a position near the target of the neutron generator and a remote location where photon transmission measurements were conducted. A sodium iodide scintillator was employed to detect the photons. Pulses equivalent to photon energies smaller than 2.506 MeV (corresponding to the cascade sum of 1.333- and 1.173-MeV gamma rays from the decay of 5.271-year 60 Co) were rejected by the electronics settings in order to reduce background and improve the signal-to-noise (S/N) ratio. Respectable S/N ratios on the order of 20-to-1 were achieved with this setup. Most of the background (N) could be attributed to ambient environmental radiation and cosmic-ray interactions with the lead shielding and detector. Four representative objects were examined by photon radiography in this study. This demonstrated how such - interesting features as hidden holes and discontinuities in atomic number could be easily identified from observed variations in the intensity of transmitted photons. Some advantages of this technique are described, and potential applications are suggested for a future scenario where fusion reactors are used to generate electric power and very intense sources of high-energy photons from 16 N decay are continuously available as a byproduct of the reactor cooling process

  10. Spallation and 14-MeV neutron irradiation of stabilized NbTi superconductors

    International Nuclear Information System (INIS)

    Hahn, P.; Brown, B.S.; Weber, H.W.; Guinan, M.W.

    1983-08-01

    The results on 5 K irradiation available so far may be summarized as follows. (1) Increases of j/sub c/ following neutron irradiation occur only in conductors which are far from the optimal metallurgical treatments. (2) The changes of j/sub c/ following neutron irradiation and a thermal cycle to room temperature are small and in most cases comparable to the results obtained after 77 K irradiation. (3) The data available so far indicate that the degradation of j/sub c/ at 8 T is larger by about 5 to 10% than the corresponding changes at 5 T at a neutron fluence of 1.3 x 10 22 m -2 (E > 0.1 MeV). (4) The increase of Cu-resistivity is significant even after a thermal cycle to room temperature and requires design changes for a stable magnet operation

  11. Vessel wall damage by X-rays and 15 MeV neutrons

    International Nuclear Information System (INIS)

    Aarnoudse, M.W.

    1979-01-01

    In two simple mucopolysaccharide systems, synovial fluid and subcutaneous connective tissue membranes, the degrading effects of 200 kVp X-rays and 15 MeV neutrons is compared. Due to the depolymerization of the mucopolysaccharides the viscosity of synovial fluid decreases and the permeability of the connective tissue membranes for saline increases after irradiation. In both systems a RBE of 0.6 has been found for fast neutrons. The atheromatous changes in the wall of elastic arteries (lipid penetration into the vessel wall and the formation of plaques consisting of large, lipid-filled foam cells) are studied in the carotid arteries of hypercholesterolemic rabbits, two months after irradiating the arteries with different doses of X-rays or neutrons. (Auth.)

  12. Study of associated gamma from niobium under 14. 9 MeV neutron bombardments

    Energy Technology Data Exchange (ETDEWEB)

    Zhou Hongyu; Yan Yiming; Fan Guoying; Lan Liqiac; Sun Suxu; Wang Qi; Hua Ming; Han Chongzhen; Liu Shuzhenn; Rong Yaning; and others

    1989-02-01

    The gamma ray spectra from niobium under 14.9 MeV neutron bombardments were measured by means of a pulsed /ital T/(/ital d/, /ital n/)/sup 4/He neutron source, associated particle method, Ge(Li) detector and time-of-flight technique at 7 angles between 30/degree/ and 140/degree/. 79 gamma lines were determined by a high resolution gamma spectrum analysis program, and reaction types and transition levels of 62 lines were roughly assigned. There were 40 ones of 79 lines, which were first found in reactions induced by neutrons. The differential cross sections of every gamma line at 7 angles were determined. It is shown that associated gamma ray emissions from this reaction are basically isotropic.

  13. Design status of an intense 14 MeV neutron source for cancer therapy

    CERN Document Server

    Yao, Z E; Cheng, S W; Jia, W B

    2002-01-01

    Design and development of an intense 14 MeV neutron source for cancer therapy is in progress at the Institute of Nuclear Research of Lanzhou University. The neutrons from the T(d,n) sup 4 He reaction are produced by bombarding a rotating titanium tritide target with a 40 mA deuteron beam at 600 keV. The designed neutron yield is 8x10 sup 1 sup 2 n/s and the maximum dose rate at a 100 cm source-to-skin distance is 25 cGy/min. The HV terminal, accelerating column and HV power supply are enclosed inside a stainless steel pressure vessel containing 6 atm SF sub 6 gas to provide the electrical insulation.

  14. Secondary standards (non-activation) for neutron data measurements above 20 MeV

    International Nuclear Information System (INIS)

    Haight, R.C.

    1991-01-01

    In addition to H(n,p) scattering and 235,238 U(n,f) reactions, secondary standards for neutron flux determination may be useful for neutron energies above 20 MeV. For experiments where gamma rays are detected, reference gamma-ray production cross sections are relevant. For neutron-induced charged particle production, standard (n,p) and (n,alpha) cross sections would be helpful. Total cross section standards would serve to check the accuracy of these measurements. These secondary standards are desirable because they can be used with the same detector systems employed in measuring the quantities of interest. Uncertainties due to detector efficiency, geometrical effects, timing and length of flight paths can therefore be significantly reduced. Several secondary standards that do not depend on activation techniques are proposed. 14 refs

  15. Helium production by 10 MeV neutrons in iron, nickel and copper

    International Nuclear Information System (INIS)

    Haight, R.C.; Kneff, D.W.; Oliver, B.M.; Greenwood, L.R.; Vonach, H.

    1994-01-01

    Helium production cross sections for the elements Fe, Ni, and Cu and for the isotopes 56 Fe, 58 Ni and 60 Ni have been measured for 10-MeV neutrons. Samples were irradiated with an intense neutron source from the 1 H(t,n) reaction using a rotating gas cell. The generated helium was determined by isotope dilution gas mass spectrometry. Induced radioactivities and known cross sections were used together with calculations based on the source reaction to deduce the neutron fluence at each sample position. The results are in fair agreement with literature values for (n,α) cross sections measured by α-particle detection and integrated over the α-particle energies and angular distributions

  16. Measurements of double-differential neutron emission cross sections of {sup 6}Li and {sup 7}Li for 18 MeV neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Ibaraki, Masanobu; Baba, Mamoru; Matsuyama, Shigeo; Sanami, Toshiya; Win, T.; Miura, Takako; Hirakawa, Naohiro [Tohoku Univ., Sendai (Japan). Faculty of Engineering

    1997-03-01

    Double-differential neutron emission cross sections of {sup 6}Li and {sup 7}Li were measured for 18 MeV neutrons at Tohoku University 4.5 MV Dynamitron facility. Neutron emission spectra were obtained down to 1 MeV at 13 angles with energy resolution good enough to separate discrete levels. A care was taken to eliminate the sample-dependent background due to parasitic neutrons. Experimental results were in fair agreement with the JENDL-3.2 data and a simple model considering a three-body breakup process and discrete level excitations. (author)

  17. Inelastic scattering of 1-2.5 MeV neutrons by 235U and 238U nuclei

    International Nuclear Information System (INIS)

    Kornilov, N.V.; Kagalenko, A.B.; Baryba, V.Ya.; Balitskij, A.V.; Androsenko, A.A.; Androsenko, P.A.

    1993-07-01

    The inelastic scattering cross-sections of 1-2.5 MeV neutrons for 235 U and 238 0 nuclei were measured. A detailed description is given of the data processing procedures used, and the methods for determining the neutron flux in the sample. The Monte Carlo method was used to calculate the corrections for multiple neutron scattering and neutron flux attenuation in the sample. Pursuant to an analysis of the fission neutron spectra, we concluded that the systematic error level of the results is ± 3.27%. The results of these cross-section and spectrum measurements for inelastically scattered neutrons are compared with results from other sources and existing evaluations, the possible causes of the divergences for neutrons with an energy level of less than 1 MeV are analysed, and suggestions are put forward for future research work. (author)

  18. Measurement of the 64Zn,47Ti(n,p) cross sections using a DD neutron generator for medical isotope studies

    Science.gov (United States)

    Voyles, A. S.; Basunia, M. S.; Batchelder, J. C.; Bauer, J. D.; Becker, T. A.; Bernstein, L. A.; Matthews, E. F.; Renne, P. R.; Rutte, D.; Unzueta, M. A.; van Bibber, K. A.

    2017-11-01

    Cross sections for the 47Ti(n,p)47Sc and 64Zn(n,p)64Cu reactions have been measured for quasi-monoenergetic DD neutrons produced by the UC Berkeley High Flux Neutron Generator (HFNG). The HFNG is a compact neutron generator designed as a "flux-trap" that maximizes the probability that a neutron will interact with a sample loaded into a specific, central location. The study was motivated by interest in the production of 47Sc and 64Cu as emerging medical isotopes. The cross sections were measured in ratio to the 113In(n,n‧)113mIn and 115In(n,n‧)115mIn inelastic scattering reactions on co-irradiated indium samples. Post-irradiation counting using an HPGe and LEPS detectors allowed for cross section determination to within 5% uncertainty. The 64Zn(n,p)64Cu cross section for 2.76-0.02+0.01 MeV neutrons is reported as 49.3 ± 2.6 mb (relative to 113In) or 46.4 ± 1.7 mb (relative to 115In), and the 47Ti(n,p)47Sc cross section is reported as 26.26 ± 0.82 mb. The measured cross sections are found to be in good agreement with existing measured values but with lower uncertainty (neutron sources for nuclear data measurements and potentially the production of radionuclides for medical applications.

  19. Measurement of cross sections for the scattering of neutrons in the energy range from 2 MeV to 4 MeV with the 15N(p,n) reaction as neutron source

    International Nuclear Information System (INIS)

    Poenitz, Erik

    2010-01-01

    In future nuclear facilities, the materials lead and bismuth can play a more important role than in today's nuclear reactors. Reliable cross section data are required for the design of those facilities. In particular the neutron transport in the lead spallation target of an Accelerator-Driven Subcritical Reactor strongly depends on the inelastic neutron scattering cross sections in the energy region from 0.5 MeV to 6 MeV. In the recent 20 years, elastic and inelastic neutron scattering cross sections were measured with high precision for a variety of elements at the PTB time-of-flight spectrometer. The D(d,n) reaction was primarily used for the production of neutrons. Because of the Q value of the reaction and the available deuteron energies, neutrons in the energy range from 6 MeV to 16 MeV can be produced. For the cross section measurement at lower energies, however, another neutron producing reaction is required. The 15 N(p,n) 15 O reaction was chosen, as it allows the production of monoenergetic neutrons with up to 5.7MeV energy. In this work, the 15 N(p,n) reaction was studied with focus on the suitability as a source for monoenergetic neutrons in scattering experiments. This includes the measurement of differential cross sections for the neutron producing reaction and the choice of optimum target conditions. Differential elastic and inelastic neutron scattering cross sections were measured for lead at four energies in the region from 2 MeV to 4 MeV incident neutron energy using the time-of-flight technique. A lead sample with natural isotopic composition was used. NE213 liquid scintillation detectors with well-known detection efficiencies were used for the detection of the scattered neutrons. Angle-integrated cross sections were determined by a Legendre polynomial expansion using least-squares methods. Additionally, measurements were carried out for isotopically pure 209 Bi and 181 Ta samples at 4 MeV incident neutron energy. Results are compared with other

  20. Conceptual Design of a 14-MeV D-T Neutron Source for Material Inspection

    International Nuclear Information System (INIS)

    Kim, Jin-Choon; Oh, Byung-Hoon

    2007-01-01

    There is a worldwide need for the efficient inspection of cargo containers at airports, seaports and border crossings. And there is also a growing need for nondestructive inspection of metal objects such as airplane parts. The limitations of X-ray systems for the detection of explosives, drugs, and thick metal structures have stimulated interest in neutron radiograph or tomography. The weak link in such applications is the neutron source. The ideal neutron source should provide a high intensity, high-energy for sufficient penetration and activation, a reliable long-term operation, and a monoenergetic neutron beam. In this paper, we describe a conceptual design of a DT fusion neutron source (monoenergetic 14 MeV neutron generator) which satisfies the fore-mentioned requirements. The current design is based upon the actually proven system using the drive-in target principle. The design is versatile enough to accommodate various applications, ranging from material inspection and explosive interrogation to medical probing and cancer treatment

  1. Study of the response of a silicon detector irradiated with 1 MeV neutrons; Etude de la reponse d`un detecteur Si irradie par des neutrons de 1 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Roy, P [Montreal Univ., PQ (Canada). Lab. de Physique Nucleaire

    1994-12-31

    The author studied the response of an n-type silicon detector irradiated with 1 MeV neutrons at fluences ranging from 0.26x10{sup 13} to 11.19x10{sup 13} neutrons/cm{sup 2}. The response of the irradiated detector to {sup 241}Am alpha particles was measured. 13 refs., 7 figs.

  2. Combined proton-recoil and neutron time-of-flight spectrometer for 14 MeV neutrons

    International Nuclear Information System (INIS)

    Grosshoeg, G.; Aronsson, D.; Arvidsson, E.; Beimer, K.-H.; Pekkari, L.-O.; Rydz, R.; Sjoestrand, N.G.

    1983-05-01

    The main effort put into this work is the foundation of a reliable physical basis for a 12-16 MeV neutron-spectrometer at JET. The essential problem is the amount of scatterer that can be incorporated without losing resolution. We have found two possible methods, the use of a pure hydrogen scatterer and the use of a polyethylene foil scatterer. The pure hydrogen solution gives a very complicated spectrometer with large detectors. The polyethylene solution is limited by the thickness and the width of the foil. We judge the solution with the polyethylene foil to be the most promising one for a reliable spectrometer. However, a large foil area is needed. This gives a spectrometer design with an annular foil, an annular neutron detection system, and a central proton-detector. An efficiency of 10 - 6 counts/s per n/cm 2 ,s at the foil can be obtained with a resolution in the order of 100 keV for 14 MeV neutrons. Following the General Requirements given in the contract of this work, we concluded that an instrument with the desired properties can be made. The instruments is able to give useful information about the plasma from plasma temperatures of about 5 keV. (Authors)

  3. Ion tail formation and its effect on 14-MeV neutron generation in D-3He plasmas

    International Nuclear Information System (INIS)

    Matsuura, H.; Nakao, Y.; Kudo, K.

    1992-01-01

    This paper reports on the triton distribution function in D- 3 He plasmas which is distorted from a Maxwellian owing to the presence of a 1.01-MeV birth component. The deuteron-triton reaction rate (i.e., 14-MeV neutron generation rate) in the plasma should be smaller than the values evaluated by assuming a Maxwellian triton distribution. A local Fokker-Planck calculation shows that although the degree of the decrease in 14-MeV neutron generation strongly depends on the plasma conditions and also on the energy loss mechanism, it becomes appreciable in actual burning plasmas

  4. Generation of 300 MeV Quasi-Monochromatic Electron Beams from Laser Wakefield and Initiation of Photonuclear Reactions

    Science.gov (United States)

    Maksimchuk, A.; Beene, J. R.

    2005-10-01

    In the interaction of 30 fs, 40 TW Ti:sapphire Hercules laser at the University of Michigan, which is focused to the intensity of 10^19 W/cm^2 onto a supersonic He gas jet with electron density close to the resonant density, we observed quasi-monoenergetic electron beams with energy up to 300 MeV and angular divergence of about 10 mrad. The results on characterization of relativistic electron beam in terms of energy spread, its charge, divergence and pointing stability will be presented. 2D PIC simulations performed for the parameters close to the experimental conditions show the evolution of the laser pulse in plasma, electron injection, and the specifics of electron acceleration observed in experiments. Resulted relativistic electron beams have been used to perform gamma-neutron activation of ^12C and ^63Cu and photo-fission of ^238U. We demonstrated that approximately 10^6 reaction per shot has been produced in each case. This work was supported by the NSF through the Physics Frontier Center FOCUS. JRB, DRS, DWS, and CRV acknowledge support by the DOE under contract DE-AC05-00OR22725 with UT-Battelle, LLC.

  5. Measurement of the fission cross-section ratio for 237Np/235U around 14 MeV neutron energies

    International Nuclear Information System (INIS)

    Desdin, L.; Szegedy, S.; Csikai, J.

    1989-01-01

    Fission cross-section ratio was determined for 237 Np/ 235 U around 14 MeV neutron energies with a back-to-back ionization chamber. Neutrons were produced by a 180 KV accelerator using T(d,n) 4 He reaction. No significant energy dependence was found in the cross section ratio

  6. Analysis of the experimental data on carbon-neutron interactions for energy below 20MeV

    International Nuclear Information System (INIS)

    Haouat, G.; Lachkar, J.; Patin, Y.; Sigaud, J.; Cocu, F.

    1975-01-01

    An evaluation of the neutron-induced cross sections of carbon has been completed for the energy region 10 -4 eV to 20MeV. The recommended data are based on experiments, some of them being done in this laboratory. Energy and angular distributions of secondary neutrons and photons are included. The adopted values are discussed [fr

  7. Absolute measurement and international intercomparison of 0.1-0.8 MeV monoenergetic neutron fluence rate

    International Nuclear Information System (INIS)

    Ma Hongchang; Lu Hanlin; Rong Chaofan

    1988-01-01

    The methods for absolute measurement of 0.1-18MeV monoenergetic neutron fluence rate are described. Which include proton recoil telescope, semicoducetor telescope, hydrogen filled proportional counter and associated particale method. A long counter used as secondary recent international intercomparison of neutron fluence rate organized by BIPM, and the results were given

  8. Response of Inorganic Scintillators to Neutrons of 3 and 15 MeV Energy

    CERN Document Server

    Lucchini, M; Pizzichemi, M; Chipaux, R; Jacquot, F; Mazue, H; Wolff, H; Lecoq, P; Auffray, E

    2014-01-01

    In the perspective of the development of future high energy physics experiments, homogeneous calorimeters based on inorganic scintillators can be considered for the detection of hadrons (e.g., calorimeter based on dual-readout technique). Although of high importance in the high energy physics framework as well as for homeland security applications, the response of these inorganic scintillators to neutrons has been only scarcely investigated. This paper presents results obtained using five common scintillating crystals (of size around 2x2x2 cm 3), namely lead tungstate (PbWO4), bismuth germanate (BGO), cerium fluoride (CeF3), Ce-doped lutetium-yttrium orthosilicate (LYSO:Ce) and lutetium aluminum garnet (LuAG:Ce) in a pulsed flux of almost mono-energetic (similar to 3 MeV and similar to 15 MeV) neutrons provided by the Van de Graff accelerator SAMES of CEA Valduc. Energy spectra have been recorded, calibrated and compared with Geant4 simulations computed with different physics models. The neutron detection eff...

  9. Beam dynamics studies of a 30 MeV RF linac for neutron production

    Science.gov (United States)

    Nayak, B.; Krishnagopal, S.; Acharya, S.

    2018-02-01

    Design of a 30 MeV, 10 Amp RF linac as neutron source has been carried out by means of ASTRA simulation code. Here we discuss details of design simulations for three different cases i.e Thermionic , DC and RF photocathode guns and compare them as injectors to a 30 MeV RF linac for n-ToF production. A detailed study on choice of input parameters of the beam from point of view of transmission efficiency and beam quality at the output have been described. We found that thermionic gun isn't suitable for this application. Both DC and RF photocathode gun can be used. RF photocathode gun would be of better performance.

  10. Neutron scattering from 12C between 15.6 and 17.3 MeV

    International Nuclear Information System (INIS)

    Chen, Z.M.; Baird, K.; Howell, C.R.; Roberts, M.L.; Tornow, W.; Walter, R.L.

    1993-01-01

    The differential cross section σ(θ) for neutron elastic scattering from 12 C and for inelastic scattering from the 4.44 MeV state was measured at 15.57, 16.75 and 17.29 MeV. The σ(θ) data, together with published analysing power A y (θ) data, were analysed in the framework of the spherical optical model and in the coupled-channels formalism. It was concluded that the present 12 C(n,n) 12 C data and published data at higher energies appear to be well suited for determining properties of valence single-particle excitations in 11 C via an iterative-moment approach or a dispersive optical-model analysis. (author)

  11. Neutron scattering from [sup 12]C between 15. 6 and 17. 3 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Z.M.; Baird, K.; Howell, C.R.; Roberts, M.L.; Tornow, W.; Walter, R.L. (Duke Univ., Durham, NC (United States). Dept. of Physics Triangle Universities Nuclear Lab., Durham, NC (United States))

    1993-06-01

    The differential cross section [sigma]([theta]) for neutron elastic scattering from [sup 12]C and for inelastic scattering from the 4.44 MeV state was measured at 15.57, 16.75 and 17.29 MeV. The [sigma]([theta]) data, together with published analysing power A[sub y]([theta]) data, were analysed in the framework of the spherical optical model and in the coupled-channels formalism. It was concluded that the present [sup 12]C(n,n)[sup 12]C data and published data at higher energies appear to be well suited for determining properties of valence single-particle excitations in [sup 11]C via an iterative-moment approach or a dispersive optical-model analysis. (author).

  12. Measurement of neutron production by 500 MeV proton beam

    International Nuclear Information System (INIS)

    Hirayama, Hideo; Ban, Shuichi

    1981-01-01

    Measurement of high energy neutrons is difficult, because the cross section data are scarce, the cross section at high energy is usually small, and the monoenergetic neutrons are hardly obtained. At the National Laboratory for High Energy Physics (KEK), various threshold detectors have been used for high energy neutron measurement. A carbon detector is a standard detector for high energy neutrons, since the cross section of the C 12 (n, 2n) C 11 reaction is almost constant at higher energy than 20 MeV, and the data have been well known. The half-life of the product (C 11 ) is about 20 min, and other activities with longer half-life than 1 min are restricted to Be 7 and C 11 . As a carbon detector, a plastic scintillator is used, and the neutron spectra observed at the Booster Beam Dump Room of KEK are presented. The results of measurements were compared with the calculated results using a Monte Carlo code made at KEK. Agreement between both results was good. (Kato, T.)

  13. Experimental study of the interaction of 14-MeV neutrons with 238U

    International Nuclear Information System (INIS)

    Voignier, J.

    1968-01-01

    A study has been made of the interaction of fast neutrons with natural uranium from the experimental point of view over a wide energy range. The scattering energy spectra have been obtained by the time-of-flight method developed during previous work. The cross-section σ t , the elastic cross-section σ e , and the inelastic neutron emission cross-section σ ne have been measured at 14 MeV. The average number, η, of neutrons produced by interaction is deduced from this last measurement. The experimental results are analyzed in the second part of the report. The fission spectrum and the evaporation spectrum have been deduced from the energy spectrum of the secondary neutrons. The energy spectrum of the inelastic neutrons is represented by a relationship of the type:N (E) = A E exp (-E/T e ) + B √ E exp (-E/T f )/. The parameter A, B, T e and T f have been evaluated. Finally the values obtained for the various cross sections are compared with previous results. (author) [fr

  14. Neutron Inelastic Scattering on 134Xe at En = 5 - 8 MeV

    Science.gov (United States)

    Kidd, Mary; Tornow, Werner; Finch, Sean; Krishichayan, Fnu; Bhike, Megha

    2017-09-01

    Neutrinoless double-beta decay (0 νββ) studies are both the best way to determine the Majorana nature of the neutrino and determine its effective mass. The two main experiments searching for 0 νββ -decay of 136Xe (Q value = 2457.8 keV) are Kamland-Zen and EXO-200. Though both experiments have enriched 136Xe targets, these targets still contain significant quantities of 134Xe. Recently, a new nuclear level was discovered in 134Xe that decays to the ground state emitting a 2485.7 keV gamma ray. The γ-ray production cross section for this branch was found to be on the order of 10 mb for incident neutron energies of 2.5-4.5 MeV. Here, we have extended the investigation of this level to higher incident neutron energies, and further explore the potential neutron-induced backgrounds on both 134Xe and 136Xe for extended neutron energies. We will report our preliminary results for neutron inelastic scattering on 134Xe in applications to 0 νββ decay searches. NSF PHY-1614348, DE-FG02-97ER41033.

  15. The SCANDAL facility - How to measure elastic neutron scattering in the 50-130 MeV range

    International Nuclear Information System (INIS)

    Klug, Joakim

    2001-01-01

    The interest in neutrons of energies above 20 MeV is growing rapidly, since new applications are being developed or have been identified. Transmutation of nuclear waste and cancer therapy with neutron beams are two research fields that would benefit from new neutron scattering data at these energies. A facility for detection of scattered neutrons in the energy interval 50-130 MeV, SCANDAL (SCAttered Nucleon Detection AssembLy), has been developed and installed at the neutron beam facility of the The Svedberg Laboratory in Uppsala. It can be used to study the (n,n), (n,p) and (n,d) reactions. This thesis describes the layout of the setup, the experimental procedure, and data analysis principles. The performance of the spectrometer is illustrated with measurements of the (n,p) and (n,n) reactions on 1 H and 12 C. In addition, the neutron beam facility is described in some detail

  16. The method to set up file-6 in neutron data library of light nuclei below 20 MeV

    International Nuclear Information System (INIS)

    Zhang Jingshang; Han Yinlu

    2001-01-01

    So far there is no file-6 (double differential cross section data, DDX) of the light nuclei in the main evaluated neutron nuclear data libraries in the world. Therefore, locating a proper description on the double differential cross section of all kinds of outgoing particles from neutron induced light nucleus reaction below 20 MeV is necessary. The motivation for this work is to introduce a way to set up file-6 in the neutron data library

  17. Increase of the electrical resistance of thin aluminium film due to 14 MeV neutron irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Agrawal, S K; Kumar, U; Singh, S P; Bhattacharya, S; Nigam, A K [Banaras Hindu Univ. (India). Dept. of Physics

    1978-01-01

    The effect of 14 MeV neutron bombardment on the electrical resistance of 500 A thick vacuum-coated Al film is investigated. In the beginning, a slow, then sharp and finally again slow increase is observed in the electrical resistance of the film. Transmission electron micrographs of the film after the same dose of neutron irradiation show a large number of defects produced in the film due to neutron irradiation, which seems to be the cause of this increase.

  18. Reactor physics experiments in PURNIMA sub critical facility coupled with 14 MeV neutron source

    International Nuclear Information System (INIS)

    Kumar, Rajeev; Degweker, S.B.; Patel, Tarun; Bishnoi, Saroj; Adhikari, P.S.

    2011-01-01

    developed at BARC. Hence it is important to experimentally study the statistical properties of the neutron source for noise experiments. To characterize the statistical properties of the 14 MeV neutron source, neutron counts were collected from DD as well as DT reaction using a time stamping data acquisition card. Data were analyzed to obtain the v/m, auto correlation function and power spectral density (PSD). The study indicates that the source is different from a purely Poisson source. (author)

  19. Elastic neutron-proton differential cross section at 647 MeV

    International Nuclear Information System (INIS)

    Evans, M.L.

    1979-04-01

    The differential cross section for n-p elastic scattering in the angular range 51 0 was measured with high statistical accuracy using the 647 MeV monoenergetic neutron beam of the Los Alamos Meson Physics Facility. A proton recoil magnetic spectrometer was used for momentum analysis of the charge exchange protons from the reaction n+p→p+n. Absolute normalization of the cross section was established to within 7% using existing cross section data for the reaction p+p→π + +d. The results differ significantly from previous Dubna and PPA cross sections but agree well with recent Saclay data except at extreme backward angles. 41 references

  20. Blank evaluation in nitrogen determination in seed grains by 14 MeV neutron activation analysis

    International Nuclear Information System (INIS)

    Wasek, M.; Sterlinski, S.

    1987-01-01

    In this work the term 'blank' signifies total radiation of the sample analyzed except that the element to be determined (analyte) is absent. On the basis of the evaluation of the blank components (nuclear and spectral interferences, air-nitrogen between grains, etc.), a semiempirical formula for calculating the nitrogen content in plant grain samples is proposed. The reliability of the results obtained with the use of this formula was demonstrated for five sorts of seeds (rye, wheat, barley, broad bean and soybean) which were analyzed by the Kjeldahl method and 14 MeV neutron activation analysis, respectively. (author)

  1. Evaluated neutron-induced cross sections for 40Ca from 20 to 40 MeV

    International Nuclear Information System (INIS)

    Hetrick, D.M.; Fu, C.Y.; Larson, D.C.

    1982-09-01

    Nuclear model codes were used to compute cross sections for neutron-induced reactions on 40 Ca for incident energies from 20 to 40 MeV. The input parameters for the model codes were determined through analysis of experimental data in this energy region. Computed cross sections along with emission spectra for each product were combined into an Evaluated Nuclear Data File (ENDF) using the proposed format for charged-particle reactions. Discussion of the models used, the resulting calculations, and the final evaluated data file are presented

  2. Measurements of neutron-deuteron breakup cross sections at 13.0 MeV

    International Nuclear Information System (INIS)

    Setze, H.R.; Howell, C.R.; Tornow, W.

    1993-01-01

    The discrepancy between low-energy nucleon-deuteron breakup cross-section data and calculations, which do not include three-nucleon forces, has been cited as a possible signature of the influence of three-nucleon forces section. The comparison between data and calculations is difficult to interpret because there are significant disagreements between the data. To help clarify the situation we have made kinematically complete cross-section measurements for n-d breakup at an incident neutron energy of 13.0 MeV. The experimental techniques and data analysis method will be described. Preliminary results will be presented in comparison to calculations and previous data

  3. Measurement and analysis of 14 MeV neutron-induced double-differential neutron emission cross sections needed for fission and fusion reactor technology

    International Nuclear Information System (INIS)

    Wang Dahai.

    1990-10-01

    The main objectives of this IAEA Co-ordinated Research Programme are to improve the data on 14 MeV neutron-induced double-differential neutron emission cross sections for materials needed for fission and fusion reactor technology. This report summarizes the conclusions and recommendations which were agreed by all participants during the Second Research Co-ordination Meeting

  4. A new method for the determination of unknown neutron fluence for 14.0 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Malik, Fariha [Physics Reasearch Division, PINSTECH, Nilore, Islamabad (Pakistan)]. E-mail: fariha@pinstech.org.pk; Khan, Ehsan U. [Department of Physics, CIIT, Islamabad (Pakistan); Qureshi, Imtinan [Physics Reasearch Division, PINSTECH, Nilore, Islamabad (Pakistan); Husaini, Syed N. [Physics Reasearch Division, PINSTECH, Nilore, Islamabad (Pakistan); Ahmad, Waqar [Physics Reasearch Division, PINSTECH, Nilore, Islamabad (Pakistan); Rajput, Usman [Physics Reasearch Division, PINSTECH, Nilore, Islamabad (Pakistan); Raza, Qaiser [Applied Physics Division, PINSTECH, Nilore, Islamabad (Pakistan)

    2006-11-15

    Measuring the correct neutron fluence in various energy intervals in and around the neutron sources is important for the purpose of personnel and environmental neutron dosimetry. In this paper, we present a new method for the measurement of the fluence of mono-energetic neutrons having the energy of 14.0 MeV. The samples exposed to neutrons from the 14.0 MeV neutron generator at PINSTECH with various fluence values ranging from 10{sup 7} to 10{sup 10} n cm{sup -2} were etched for 10 min in 6 N NaOH at 70.0{+-}1.0 {sup o}C and the transmittance of UV radiation was measured using a spectrophotometer. This procedure was repeated 20 times after etching the same sample each time for increasing time intervals till the stage when transmittance reached the constant minimum value. An exponential decay of the transmittance has been observed with respect to the increasing etching time interval in each of the samples exposed to various neutron fluence. Further, it has also been observed that there is a linear relationship between the transmittance decay constant and neutron fluence. Hence, the linear graph can be used as a calibration for measuring the unknown fluence of 14.0 MeV neutrons.

  5. Determination of oxygen in coals by activation analysis with 14 MeV neutrons

    International Nuclear Information System (INIS)

    Arbildo, A.; Espinosa, R; Poma, C.; Eyzaguirre, J.; Hinostroza, H.

    1989-01-01

    A method for non-destructive oxygen determination in coals was developed. It is based on O-16(n,p)N-16 nuclear reaction with 14 MeV neutrons produced in an AID-J 25 neutron generator. This analysis was possible because of the interface development to control the whole irradiation process and subsequent measures of N-16 produced activity from a microcomputer this method was additionally automated by the software development to treat the recorded spectrum in a multiscalimeter analyser. It is described our computer programs and it is shown the results for coal samples from different origins. It is estimated the organic carbon coal in samples from the oxygen analysis. And it is suggested a correlatian between such content and volatile material. Irradiating, decreasing and counting time added up 45 seconds, giving a fast analysis and obtaining accuracy between 1 and 3

  6. Pulsed-neutron production at the Brookhaven 200-MeV linac

    International Nuclear Information System (INIS)

    Ward, T.E.; Alessi, J.; Brennan, J.; Grand, P.; Lankshear, R.; Montemurro, P.; Snead, C.L. Jr.; Tsoupas, N.

    1988-01-01

    The new 750-kV RFQ preinjector and double chopper system capable of selecting single nanosecond micropulses with repetition rates of 0.1--20 MHz has been installed at the Brookhaven 200-MeV proton linac. The micropulse intensity is approximately 1 x 10 9 p/μpulse. Neutron time-of-flight path lengths of 30--100 meter at 0/degree/, 12/degree/, 30/degree/, 45/degree/, 90/degree/ and 135/degree/ are available, as well as a zero degree swinger capable of an angular range of 0--25/degree/. Pulsed neutron beams of monoenergetic (p 7 Li → n 7 Be) and spallation (p 238 U → nx) sources will be discussed in the present paper, as well as detailing the chopped-beam capabilities. 11 refs., 5 figs., 1 tab

  7. Pulsed-neutron production at the Brookhaven 200-MeV linac

    International Nuclear Information System (INIS)

    Ward, T.E.; Alessi, J.; Brennan, J.; Grand, P.; Lankshear, R.; Montemurro, P.; Snead, C.L. Jr.; Tsoupas, N.

    1989-01-01

    The new 750-kV RFQ preinjector and double chopper system capable of selecting single nanosecond micropulses with repetition rates of 0.1 to 20 MHz has been installed at the Brookhaven 200-MeV proton linac. The micropulse intensity is approximately 1 x 10 9 p/μpulse. Neutron time-of-flight path lengths of 30 to 100 meters at 0 degree, 12 degree, 30 degree, 45 degree, 90 degree and 135 degree are available as well as a zero-degree beam swinger capable of an angular range of 0 degree to 25 degree. Pulsed neutron beams of monoenergetic (p 7 Li → n 7 Be) and spallation (p 238 U → nx) sources will be discussed in the present paper as well as detailing the chopped-beam capabilities. 11 refs., 5 figs., 1 tab

  8. Integral benchmark for the attenuation of 14 MeV neutrons passing through lead layers

    International Nuclear Information System (INIS)

    Antonov, S.; Vojkov, G.; Ilieva, K.; Jordanova, J.

    1987-01-01

    The attenuation has been studied of the total 14 MeV neutron flux passing through an iron collimator and directly located behind lead slabs with thicknesses 2.5, 5.0, 7.5, 10.0 and 12.5 cm. A comparison is made between the calculated data and results from a benchmark experiment. The experiment is analysed with an one-dimensional model based on ANISN-code and a tree-dimentional model based on MORSE-code (Monte Carlo method). The energy dependences of the cross-sections and neutron fluxes are represented by a 25-group approximation based on the SUPERTOG program and the files ENDL and ENDF/B-4. The mean deviation of MORSE calculated data from experimental ones is 6.4% for ENDL-data and 8.5% for EDDF-data. ANISN-calculated data show practically full coincidence with experimental ones both for ENDL and ENDF

  9. Absolute determination of copper and silver in ancient coins using 14 MeV neutrons

    Science.gov (United States)

    Chalouhi, Ch.; Hourani, E.; Loos, R.; Melki, S.

    1982-09-01

    A method for absolute determination of copper and silver in ancient coins is described. Activation analysis by 14 MeV neutrons is performed. In the experimental procedure emphasis is placed on corrections for neutrons and gamma attenuation. In the analytical procedure, a multi linear-regression calculation is used to separate different contributions to the 511 keV gamma peak. The precision in the absolute determination of Cu and Ag is better than 2% in recent coins of definite shapes, whereas it is a somewhat lower in ancient coins of irregular shapes. The method was applied to ancient coins provided by the Museum of the American University of Beirut. Overall consistency and suitability of the method were obtained.

  10. Absolute determination of copper and silver in ancient coins using 14 MeV neutrons

    International Nuclear Information System (INIS)

    Chalouhi, C.; Hourani, E.; Loos, R.; Melki, S.

    1982-01-01

    A method for absolute determination of copper and silver in ancient coins is described. Activation analysis by 14 MeV neutrons is performed. In the experimental procedure emphasis is placed on corrections for neutrons and gamma attenuation. In the analytical procedure, a multi linear-regression calculation is used to separate different contributions to the 511 keV gamma peak. The precision in the absolute determination of Cu and Ag is better than 2% in recent coins of definite shapes, whereas it is a somewhat lower in ancient coins of irregular shapes. The method was applied to ancient coins provided by the Museum of the American University of Beirut. Overall consistency and suitability of the method were obtained. (orig.)

  11. Absolute determination of copper and silver in ancient coins using 14 MeV neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Chalouhi, C.; Hourani, E.; Loos, R.; Melki, S. (Faculty of Science, Beirut (Lebanon))

    1982-09-15

    A method for absolute determination of copper and silver in ancient coins is described. Activation analysis by 14 MeV neutrons is performed. In the experimental procedure emphasis is placed on corrections for neutrons and gamma attenuation. In the analytical procedure, a multi linear-regression calculation is used to separate different contributions to the 511 keV gamma peak. The precision in the absolute determination of Cu and Ag is better than 2% in recent coins of definite shapes, whereas it is a somewhat lower in ancient coins of irregular shapes. The method was applied to ancient coins provided by the Museum of the American University of Beirut. Overall consistency and suitability of the method were obtained.

  12. Measurement of the neutron and gamma-ray spectra originating from a 14-MeV neutron source in liquid nitrogen and liquid air

    International Nuclear Information System (INIS)

    Broecker, B.; Clausen, K.; Schneider-Kuehnle, P.; Weinert, M.

    1975-01-01

    An experiment to measure the radiation transport originating from a 14-MeV neutron source in liquid nitrogen and liquid air is presented. Neutron and gamma-ray spectra were measured with a proton-recoil NE 213 scintillator and with four spherical proportional counters in a tank filled with liquid nitrogen or liquid air. The neutron spectra cover the energy range of 20 keV to 18 MeV. The source-detector separation varies in the liquid medium between 60 and 240 cm. The experimental setup is briefly described and the errors are estimated. (2 tables, 9 figures) (auth)

  13. Fast neutron distributions from Be and C thick targets bombarded with 80 and 160 MeV deuterons

    International Nuclear Information System (INIS)

    Pauwels, N.; Laurent, H.; Clapier, F.; Brandenburg, S.; Beijers, J. P .M.; Zegers, R. G. T.; Lebreton, H.; Saint-Laurent, M.G.; Mirea, M.

    2001-01-01

    Production of fast neutron studies have come to the fore in the past few years because of the great interest for the possible applications of induced fission to produce neutron rich ion beams. In this context, the main objective of the SPIRAL II (Systeme de Production d'Ions Radioactifs Acceleres en Ligne) and PARRNe (Production d'Atomes Radioactifs Riches en Neutrons) R and D projects is the investigation of the feasibility and of the optimum parameters for a neutron rich isotope source. Special attention is dedicated to the energy and angular distributions of the neutrons obtained through deuteron break--up in different types of converters and different incident energies. Analysis and modelling of such behaviors, together with the study of the yields of neutron induced fission, can be used to optimize the productivity of the fissioning target its geometry and designing it accordingly. The present report continues our previous studies realised for 17, 20, 28 and 200 MeV deuteron energies and it is focused on deuteron incident energies of 80 and 160 MeV. In the experiment, the double differential cross section for neutron production induced by 80 and 160 MeV deuterons impinging on thick C and Be targets, in which the incident deuterons were complete stopped, have been measured. The energy of the neutrons was determined from the time--of--flight (TOF) measurement. To obtain an energy resolution of about 4% for the fastest, forward--emitted neutrons, which have approximately beam velocity, the length of the flightpath for the detectors at angles up to 30 angle was chosen to be 6 m. At backward angles, where the neutron energies are lower, a shorter flightpath was chosen. A schematic drawing of the setup is shown. A 100 mm thick Be target and a 70 mm thick C target were used. Results are exemplified with the angular and energy distributions of neutron obtained for Be target at 80 MeV. (authors)

  14. European Collaboration for High-Resolution Measurements of Neutron Cross Sections between 1 MeV and 250 MeV

    CERN Multimedia

    Leal, L C; Kitis, G; Guber, K H; Yuasa nakagawa, K; Koehler, P E; Quaranta, A

    2002-01-01

    The experimental determination of neutron cross section data has always been of primary importance in Nuclear Physics. Many of the salient features of nuclear levels and densities can be determined from the resonant structure of such cross sections and of their decay scheme. An associated importance of precise neutron induced reaction cross sections has resulted from the worldwide interest in Accelerator Driven Systems (ADS) that has emerged at CERN and elsewhere. Many applications, such as accelerator-based transmutation of nuclear waste, energy amplification medical research, astrophysical applications and also fusion research require nuclear data that quantitatively and qualitatively go beyond the presently available traditional evaluation.\\\\ \\\\We consider a spallation driven TOF facility at the CERN-PS with an unprecedented neutron flux (1000 times the existing ones) in the broad energy range between 1 eV and 250 MeV and with very high energy resolution. The present concept for an intense neutron source m...

  15. Neutron-Neutron effective range from a comparison of n-n and n-p quasi-free scattering at 24 MeV

    International Nuclear Information System (INIS)

    Witsch, W. von; Gomez Moreno, B.; Rosenstock, W.; Franke, R.; Steinheuer, B.

    1980-01-01

    Neutron-neutron and neutron-proton quasi-free scattering have been measured at Esub(n) = 24 MeV the d + n reaction to deduce the n-n effective range from a comparison of relative cross sections, reducing considerably experimental as well as theoretical uncertainties. A Monte Carlo analysis with exact three-body calculations yields rsub(nn) = 2.65 +- 0.18 fm. (orig.)

  16. Calculation of neutron and gamma-ray energy spectra in liquid air and liquid nitrogen due to 14-MeV neutron and californium-252 sources

    International Nuclear Information System (INIS)

    Straker, E.A.; Gritzner, M.L.; Harris, L. Jr.

    1978-01-01

    Calculations of neutron and gamma-ray fluences from 14-MeV neutron and 252 Cf sources in liquid air and liquid nitrogen have been performed. These calculations were made specifically for comparison with experimental data measured at Stohl, Federal Republic of Germany. The discrete-ordinates method was utilized with neutron and gamma-ray cross sections from ENDF/B-IV. One-dimensional calculational models were developed for the sources and tank. Limited comparisons are made with experimental data

  17. Measurement of angular distribution of neutron flux for the 6 MeV race-track microtron based pulsed neutron source

    Energy Technology Data Exchange (ETDEWEB)

    Patil, B.J., E-mail: bjp@physics.unipune.ernet.i [Department of Physics, University of Pune, Pune 411 007 (India); Chavan, S.T.; Pethe, S.N.; Krishnan, R. [SAMEER, IIT Powai Campus, Mumbai 400 076 (India); Dhole, S.D., E-mail: sanjay@physics.unipune.ernet.i [Department of Physics, University of Pune, Pune 411 007 (India)

    2010-09-15

    The 6 MeV race track microtron based pulsed neutron source has been designed specifically for the elemental analysis of short lived activation products, where the low neutron flux requirement is desirable. Electrons impinges on a e-{gamma} target to generate bremsstrahlung radiations, which further produces neutrons by photonuclear reaction in {gamma}-n target. The optimisation of these targets along with their spectra were estimated using FLUKA code. The measurement of neutron flux was carried out by activation of vanadium at different scattering angles. Angular distribution of neutron flux indicates that the flux decreases with increase in the angle and are in good agreement with the FLUKA simulation.

  18. Light-Ion Production in the Interaction of 96 MeV Neutrons with Silicon

    International Nuclear Information System (INIS)

    Tippawan, U.; Dangtip, S.; Pomp, S.; Atac, A.; Bergenwall, B.; Blomgren, J.; Hildebrand, A.; Johansson, C.; Klug, J.; Mermod, P.; Oesterlund, M.; Nilsson, L.; Elmgren, K.; Olsson, N.; Jonsson, O.; Prokofiev, A.V.; Renberg, P.-U.; Nadel-Turonski, P.; Corcalciuc, V.; Watanabe, Y.

    2005-01-01

    Radiation effects induced by terrestrial cosmic rays in microelectronics, on board aircrafts as well as at sea level, have recently attracted much attention. The most important particle radiation is due to spallation neutrons, created in the atmosphere by cosmic-ray protons. When, e.g., an electronic memory circuit is exposed to neutron radiation, charged particles can be produced in a nuclear reaction. The charge released by ionization can cause a flip of the memory content in a bit, which is called a single-event upset (SEU). This induces no hardware damage to the circuit, but unwanted re-programming of memories, CPUs, etc., can have consequences for the reliability, and ultimately also for the safety of the system.Data on energy and angular distributions of the secondary particles produced by neutrons in silicon nuclei are essential input for analyses and calculation of SEU rate. In this work, double-differential cross sections of inclusive light-ion (p, d, t, 3He and α) production in silicon, induced by 96 MeV neutrons, are presented. Energy distributions are measured at eight laboratory angles from 20 deg. to 160 deg. in steps of 20 deg. Deduced energy-differential and production cross sections are reported as well. Experimental cross sections are compared to theoretical reaction model calculations and existing experimental data in the literature

  19. 208Pb(n,pxnγ) reactions for neutron energies up to 200 MeV

    International Nuclear Information System (INIS)

    Pavlik, A.; Vonach, H.

    1995-01-01

    The prompt gamma-radiation from the interaction of fast neutrons with enriched samples of 208 Pb was measured using the white neutron beam of the WNR facility at Los Alamos National Laboratory. The samples were positioned at about 40 m distance from the neutron production target. The spectra of the emitted gamma-rays were measured with a high-resolution HPGe detector. The incident neutron energy was determined by the time-of-flight method and the neutron fluence was measured with a 238 U fission chamber. In addition to the primary purpose of this experiment, the study of (n,xnγ) reactions leading to various lead isotopes, gamma transitions in the residual nuclei 207,205,203,201 Tl were analyzed. From these data gamma-production cross sections in the neutron energy range from the effective thresholds to 200 MeV were derived. The lines for the analysis had to be chosen carefully as the (n,pnxγ) cross sections are rather small and the interference with unresolved lead lines (even weak ones) would cause significant errors. The effect due to isomers with half-lives exceeding a few nanoseconds was taken into account and corrected for, if necessary. The measured cross sections were compared with the results of nuclear model calculations based on the exciton model for preequilibrium particle emission and the Hauser-Feshbach theory for compound nucleus decay. Unlike in the case of (n,xnγ) reactions the calculated results in general did not give a good description of the measured cross sections

  20. Analysing power for neutron-proton scattering at 14.1 MeV

    International Nuclear Information System (INIS)

    Brock, J.E.; Chisholm, A.; Duder, J.C.; Garrett, R.; Poletti, J.L.

    1981-01-01

    The analysing power Asub(y)(theta) for neutron-proton scattering has been measured at 14.1 MeV for c.m. angles between 50 0 and 157 0 . A polarized neutron beam was produced by the reaction 3 H(d,n) 4 He at 110 keV, using polarized deuterons from an atomic beam polarized ion source. Liquid and plastic scintillators were used for proton targets and the scattered particles were detected in an array of platic scintillators. Use of the associated alpha technique, multi-parameter recording of events and off-line computer treatment led to very low backgrounds. The results differ significantly from the predictions of the phase-shift analyses of Yale IV, Livermore X and Arndt et al. We find, however, excellent agreement with the predictions of the Paris potential of Lacombe et al. Existing n-p analysing power results up to 30 MeV are surveyed and found to be consistent. An attempt was made to look for an isospin splitting of the triplet P-wave phase shifts. (orig.)

  1. Activation of 45-MeV proton irradiation and proton-induced neutron irradiation in polymers

    International Nuclear Information System (INIS)

    Ra, Se-Jin; Kim, Kye-Ryung; Jung, Myung-Hwan; Yang, Tae-Keon

    2010-01-01

    During beam irradiation experiments with more than a few MeV energetic protons, the sample activation problem can be very severe because it causes many kinds of additional problems for the post-processing of the samples, such as time loss, inconvenience of sample handling, personal radiation safety, etc. The most serious problem is that immediate treatment of the sample is impossible in some experiments, such as nano-particle synthesizing. To solve these problems, we studied why the samples are activated and how the level of the activation can be reduced. It is known that the main reasons of activation are nuclear reactions with elements of the target material by primary protons and secondary produced neutrons. Even though the irradiation conditions are same, the level of the activation can be different depending on the target materials. For the nanoparticle synthesizing experiments, the target materials can be defined as the container and the sample itself. The reduction of the activation from the container is easier than the reduction from the sample. Therefore, we tried to reduce the activation level by changing the container materials. In this paper, the results are displayed for some candidate container materials, such as polymethyl methacrylate, polystyrene, Glass, etc., with 45-MeV and 10-nA proton beams. As a result, PS is the most suitable material for the container because of its relatively low level of the activation by protons. Also the contribution of secondary produced neutrons to the activation is negligible.

  2. Digital neutron/gamma discrimination with an organic scintillator at energies between 1 MeV and 100 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Comrie, A.C. [Department of Physics, University of Cape Town, Rondebosch 7700 (South Africa); Buffler, A., E-mail: andy.buffler@uct.ac.za [Department of Physics, University of Cape Town, Rondebosch 7700 (South Africa); Smit, F.D. [iThemba LABS, Somerset West 7129 (South Africa); Wörtche, H.J. [INCAS" 3, Dr. Nassaulaan 9. 9400 AT Assen (Netherlands)

    2015-02-01

    Three different digital implementations of pulse shape discrimination for pulses from an EJ301 liquid scintillator detector are presented, and illustrated with neutrons and gamma-rays produced by an Am–Be radioisotopic source, a D–T generator and beams produced by cyclotron-accelerated protons of energies 42, 62 and 100 MeV on a Li target. A critical comparison between the three methods is provided.

  3. Development of quasi-monochromatic p-7Li neutron generating system for 80-210 MeV

    International Nuclear Information System (INIS)

    Nakao, Noriaki; Shibata, Tokushi; Nakamura, Takashi; Uwamino, Yoshitomo; Nakanishi, Noriyoshi; Kurosawa, Tadahiro; Kim, Unju.

    1996-01-01

    Recently the requirements for the experimental data on the response characteristics of neutron detector and the cross section for neutron generation by charged particles have been increasing for shield designing. Here, a system for quasi-monochromatic neutron generation was developed in the facility of ring-cyclotron in Institute of Physical and Chemical Sciences. In this study, H 2 + accelerated to an energy range of 80-135 MeV/n and P + to 150-210 MeV was irradiated to E4 beam course and NE102A plastic scintillator was used for monitoring the neutron flux. The amount of neutrons generated was estimated from the radioactivity of 7 Be produced in 7 Li-target. The neutron spectres thus estimated as an energy range of 80-210 MeV were presented and the lower limit of these spectres was about 20 MeV. The peaks in the range of 150 and 210 MeV were comparatively wide because of the inferiority of energy resolving power at a higher energy level. (M.N.)

  4. Neutron total cross section measurements in the energy region from 47 keV to 20 MeV

    International Nuclear Information System (INIS)

    Poenitz, W.P.; Whalen, J.F.

    1983-05-01

    Neutron total cross sections were measured for 26 elements. Data were obtained in the energy range from 47 keV to 20 MeV for 11 elements in the range of light-mass fission products. Previously reported measurements for eight heavy and actinide isotopes were extended to 20 MeV. Data were also obtained for Cu (47 keV to 1.4 MeV) and for Sc, Zn, Nd, Hf, and Pt (1.8 to 20 MeV). The present work is part of a continuing effort to provide accurate neutron total cross sections for evaluations and for optical-model parameteriztions. The latter are required for the derivation of other nuclear-data information of importance to applied programs. 37 references

  5. Measurement and theoretical analysis of neutron-induced neutron-emission reactions of {sup 6}Li at 10 to 20 MeV region

    Energy Technology Data Exchange (ETDEWEB)

    Ibaraki, Masanobu; Baba, Mamoru; Matsuyama, Shigeo [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment] [and others

    1998-06-01

    We have measured the neutron elastic and inelastic scattering double-differential cross sections of {sup 6}Li at incident neutron energies of 11.5, 14.1 and 18.0 MeV. Based on this data, together with information from other works, a phenomenological neutron optical model potential (OMP) of {sup 6}Li was constructed to describe the total and elastic scattering cross sections from 5 MeV to several tens MeV. This potential also describes well the inelastic scattering to the 1st excited state (E{sub x} = 2.186 MeV) via the DWBA calculation with the macroscopic vibrational model. The continuum neutron energy spectra and angular distributions were then analyzed by the theory of final-state interaction extended to the DWBA form, with the assumption that the d-{alpha} interaction is dominant in the 3-body final state consisting of n, d and {alpha} particles. Such a calculation was found to be successful in explaining the major part of the low-excitation neutron spectra and angular distribution down to the Q-value region of -9 MeV, except for the Q-value range where the n-{alpha} quasi-free scattering will give a non-negligible contribution at forward angles. (author). 60 refs.

  6. Measurement and theoretical analysis of neutron-induced neutron-emission reactions of 6Li at 10 to 20 MeV region

    International Nuclear Information System (INIS)

    Ibaraki, Masanobu; Baba, Mamoru; Matsuyama, Shigeo

    1998-06-01

    We have measured the neutron elastic and inelastic scattering double-differential cross sections of 6 Li at incident neutron energies of 11.5, 14.1 and 18.0 MeV. Based on this data, together with information from other works, a phenomenological neutron optical model potential (OMP) of 6 Li was constructed to describe the total and elastic scattering cross sections from 5 MeV to several tens MeV. This potential also describes well the inelastic scattering to the 1st excited state (E x = 2.186 MeV) via the DWBA calculation with the macroscopic vibrational model. The continuum neutron energy spectra and angular distributions were then analyzed by the theory of final-state interaction extended to the DWBA form, with the assumption that the d-α interaction is dominant in the 3-body final state consisting of n, d and α particles. Such a calculation was found to be successful in explaining the major part of the low-excitation neutron spectra and angular distribution down to the Q-value region of -9 MeV, except for the Q-value range where the n-α quasi-free scattering will give a non-negligible contribution at forward angles. (author). 60 refs

  7. Utilizations of filtered neutron beams at Dalat nuclear research reactor

    International Nuclear Information System (INIS)

    Hien, P.D.; Chau, L.N.; Tan, V.H.; Hiep, N.T.; Phuong, L.B.

    1992-01-01

    Neutron beam utilizations in basic and applied researches have been important activities at the Dalat nuclear reactor. The neutron filters with single crystal of silicon are used to produce thermal neutrons at the tangential horizontal channel and quasi-monoenergetic 144 KeV and 54 KeV neutrons at the piercing beam tube. The paper presents some relevant characteristics of the filtered neutron beams at the two horizontal channels. Applications of neutron beams in prompt gamma-ray activation analysis and in nuclear data measurements are briefly described. (author)

  8. Exposure times and ratio of readings produced by irradiation of thermoluminescence dosemeters in PTB neutron standard fields between 0.1 MeV and 19 MeV

    International Nuclear Information System (INIS)

    Jahr, R.; Guldbakke, S.; Cosack, M.

    1979-06-01

    6 LiF and 7 LiF thermoluminescence dosimeters (TLD) irradiated in a standard field of monoenergetic neutrons (Esub(n) = 0.1 MeV to 19 MeV), respond as well to the photon as to the neutron component of this radiation field. The ratio of the two TLD readings as well as the duration of irradiation required to obtain a preset TLD reading are calculated as a function of the neutron energy. (orig.) [de

  9. RBE of 0,85 MeV neutrons in guinea pigs with intestinal form of radiation sickness

    International Nuclear Information System (INIS)

    Shaporov, V.N.; Sokolova, T.I.; Nasonova, T.A.; Aleshin, S.N.

    1989-01-01

    Relative biological effectiveness (RBE) coefficient of 0.85 MeV neutrons was 1.87 in comparison with 0.66 MeV γ-radiation ( 137 Cs) when estimated by the death rate of guinea pigs with intestinal form of radiation sickness. LD 50/5 was 5.9 and 11.06 respectively. Features of the mortality rate dynamics, clinical picture and pathoanatomical changes are discussed

  10. RBE of 0.85 MeV neutrons in Guinea pigs with a cerebral form of radiation sickness

    International Nuclear Information System (INIS)

    Shaporov, V.N.; Sokolova, T.I.; Nasonova, T.A.; Aleshin, S.I.

    1989-01-01

    The RBE coefficient of neutrons (0.85 MeV) was 1.87 in comparison with that of electron radiation (8 MeV) as determined by the death rate of guinea pigs with the cerebral form of radiation sickness. LD 50/1.5 amounted to 43.2 and 80.7 Gy. The dynamics of clinical symptoms at the height of the disease is discussed

  11. Multi-element analysis of crude-oil samples by 14.6 MeV neutron activation

    International Nuclear Information System (INIS)

    Cam, N.F.; Cigeroglu, F.; Erduran, M.N.

    1997-01-01

    The instrumental neutron activation technique, using the SAMEST T-400 neutron generator with 14.6 MeV neutrons produced from 3 H(d,n) 4 He reaction, is demonstrated for multi-element analysis of Saudi-Arabian crude-oil samples. The system parameters for the absolute method (e.g., the counting solid-angle, intrinsic efficiency of the γ-ray detector, effective neutron flux, activation cross sections, etc.)were determined and the results of elemental concentrations were presented with the corrections for all possible interferences having been carefully considered. (author)

  12. Measurement of the detection efficiency of the KLOE calorimeter for neutrons between 22 and 174 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Anelli, M. [Laboratori Nazionali di Frascati dell' INFN, Frascati (Italy); Battistoni, G. [Sezione INFN di Milano (Italy); Bertolucci, S. [Laboratori Nazionali di Frascati dell' INFN, Frascati (Italy); Bini, C. [Sapienza Universita di Roma (Italy); Sezione INFN di Roma (Italy); Branchini, P. [Sezione INFN di Roma Tre (Italy); Curceanu, C. [Laboratori Nazionali di Frascati dell' INFN, Frascati (Italy); De Zorzi, G.; Di Domenico, A. [Sapienza Universita di Roma (Italy); Sezione INFN di Roma (Italy); Di Micco, B. [Universita degli di Studi ' Roma Tre' (Italy); Sezione INFN di Roma Tre (Italy); Ferrari, A. [Fondazione CNAO, Milano (Italy); Fiore, S. [Sapienza Universita di Roma (Italy); Sezione INFN di Roma (Italy)], E-mail: salvatore.fiore@roma1.infn.it; Gauzzi, P. [Sapienza Universita di Roma (Italy); Sezione INFN di Roma (Italy); Giovannella, S.; Happacher, F. [Laboratori Nazionali di Frascati dell' INFN, Frascati (Italy); Iliescu, M. [Laboratori Nazionali di Frascati dell' INFN, Frascati (Italy); IFIN-HH, Bucharest (Romania); Martini, M.; Miscetti, S. [Laboratori Nazionali di Frascati dell' INFN, Frascati (Italy); Nguyen, F. [Universita degli di Studi ' Roma Tre' (Italy); Sezione INFN di Roma Tre (Italy); Passeri, A. [Sezione INFN di Roma Tre (Italy); Prokofiev, A. [Svedberg Laboratory, Uppsala University (Sweden)] (and others)

    2009-01-01

    A prototype of the high-sampling lead-scintillating fiber KLOE calorimeter has been exposed to neutron beams of 21, 46 and 174 MeV, provided by the The Svedberg Laboratory, Uppsala, to test its neutron detection efficiency. The measurement of the neutron detection efficiency of an NE110 scintillator provided a reference calibration. The measured efficiency is larger than what expected considering the scintillator thickness of the KLOE prototype only. This result proves the existence of a contribution from the passive material to neutron detection efficiency, in a high-sampling calorimeter configuration.

  13. Production of neutron-rich nuclei in fission induced by neutrons generated by the p+ sup 1 sup 3 C reaction at 55 MeV

    CERN Document Server

    Stroe, L; Andrighetto, A; Tecchio, L B; Dendooven, P; Huikari, J; Pentillä, H; Peraejaervi, K; Wang, Y

    2003-01-01

    Cross-sections for the production of neutron-rich nuclei obtained by neutron-induced fission of natural uranium have been measured. The neutrons were generated by bombarding a sup 1 sup 3 C target with 55 MeV protons. The results, position of the maximum in the (Z, A)-plane, width and magnitude, are very comparable with those where the neutrons are generated by bombardment of natural sup 1 sup 2 C graphite with 50 MeV deuterons. Depending on the geometry of the converter/target assembly the isotope yields, however, are a factor of 2-3 lower due to less efficient production of neutrons per primary projectile, especially at small forward angles. (orig.)

  14. Detecting neutrons by forward recoil protons at the Energy & Transmutation facility: Detector development and calibration with 14.1-MeV neutrons

    Science.gov (United States)

    Afanasev, S.; Vishnevskiy, A.; Vishnevskiy, D.; Rogachev, A.; Tyutyunnikov, S.

    2017-05-01

    As part of the Energy & Transmutation project, we are developing a detector for neutrons with energies in the 10-100 MeV range emitted from the target irradiated by a charged-particle beam. The neutron is detected by measuring the time-of-flight and total kinetic energy of the forward-going recoil proton [1] knocked out at a small angle from a thin layer of plastic scintillator, which has to be selected against an intense background created by γ quanta, scattered neutrons, and charged particles. On the other hand, neutron energy has to be measured over the full range with no extra tuning of the detector operation regime. Initial measurements with a source of 14.1-MeV neutrons are reported.

  15. Multipurpose intense 14 MeV neutron source at Bratislava: Design study

    International Nuclear Information System (INIS)

    Pivarc, J.; Hlavac, S.; Kral, J.; Oblozinsky, P.; Ribansky, I.; Turzo, I.

    1980-05-01

    The present state of design of the multipurpose intense 14 MeV neutron source based on a D + ion beam and a metal tritide target is reported. It is essentially a 300 keV electrostatic air insulated accelerator capable to accelerate a deuterium ion beam up to 10 mA. With such a beam and a beam spot of 1 cm 2 , a neutron yield typically 10 12 n/s and a useful target lifetime of around 10 h are expected. Various users requirements are met by means of three beam lines: an intense, low current dc and a low current fast pulsed. The key components of the intense source section are the rotating target and the ion source. The rotating target is proposed, with respect of the heat dissipation and the removal of 3 kW/cm 2 , in continuous operation. A rotation speed up to 1100 rpm is considered. The ion source should deliver about 0.5 kW of extracted D + ion beam power. A duoplasmatron source with an electrostatic beam focusing system has been selected. Low current sections of the neutron source may operate with a high frequency ion source as well. The dc section for maximum yields around 10 10 n/s is designed with special regard to beam monitoring. The fast pulsed section should produce up to 1 ns compressible pulsed D + ion beam on a target spot with 5 MHz repetition rate. The report includes information about other components of the neutron source as a high voltage power supply, a vacuum system, beam transport, a diagnostic and control system and basic information about neutron source cells and radiation protection. (author)

  16. V79 survival following simultaneous or sequential irradiation by 15-MeV neutrons and 60Co photons

    International Nuclear Information System (INIS)

    Higgins, P.D.; DeLuca, P.M. Jr.; Pearson, D.W.; Gould, M.N.

    1983-01-01

    A unique tandem source irradiation facility, composed of an intense d-T neutron source and a 60 Co teletherapy unit, was used to investigate biological responses for different neutron/photon configurations. V79 Chinese hamster cells, attached as monolayers in log-phase growth, were irradiated at 37 degrees C by either 14.8-MeV neutrons, 60 Co, or a mixture of 40% neutrons and 60% photons in simultaneous or sequential application. Measurements of cell survival indicate an increased effectiveness in cell killing for simultaneously administered neutrons and photons compared to that measured or predicted for sequentially applied beam modalities. An understanding of the magnitude of these interactive effects is important both for calculating accurate effective doses for neutron radiotherapy of deep-seated tumors, for which the photon component is appreciable, and for determination of environmental hazards to people occupationally exposed to mixtures of photons and neutrons

  17. V79 survival following simultaneous or sequential irradiation by 15-MeV neutrons and 60Co photons

    International Nuclear Information System (INIS)

    Higgins, P.D.; DeLuca, P.M. Jr.; Pearson, D.W.; Gould, M.N.

    1983-01-01

    A unique tandem source irradiation facility, composed of an intense d-T neutron source and a 60 Co teletherapy unit, was used to investigate biological responses for different neutron/photon configurations. V79 Chinese hamster cells, attached as monolayers in log-phase growth, were irradiated at 37 0 C by either 14.8-MeV neutrons, 60 Co, or a mixture of 40% neutrons and 60% photons in simultaneous or sequential application. Measurements of cell survival indicate an increased effectiveness in cell killing for simultaneously administered neutrons and photons compared to that measured or predicted for sequentially applied beam modalities. An understanding of the magnitude of these interactive effects is important both for calculating accurate effective doses for neutron radiotherapy of deep-seated tumors, for which the photon component is appreciable, and for determination of environmental hazards to people occupationally exposed to mixtures of photons and neutrons

  18. V79 survival following simultaneous or sequential irradiation by 14.8-MeV neutrons and 60Co photons

    International Nuclear Information System (INIS)

    Higgins, P.D.; DeLuca, P.M. Jr.; Pearson, D.W.; Gould, M.N.

    1981-01-01

    A unique tandem source irradiation facility, comprised of an intense d-T neutron source and a 60 Co teletherapy unit, has been used to investigate biological response for different neutron/photon configurations. V79 Chinese hamster cells, attached as monolayers in log phase growth, were irradiated at 37 0 C by either 14.8 MeV neutrons, 60 Co or by a mixture of 40% neutrons - 60% photons in simultaneous or sequential application. Measurements of cell survival indicate an increased effectiveness in cell killing for simultaneously administered neutrons and photons than was measured or predicted for sequentially applied beam modalities. An understanding of the magnitude of these interactive effects is important both for calculating accurate effective doses for neutron radiotherapy of deep-seated tumors, for which the photon component is appreciable and for determination of environmental hazards to people occupationally exposed to low levels of photons and neutrons

  19. Neutron-deuteron breakup experiment at En=13 MeV: Determination of the 1S0 neutron-neutron scattering length ann

    International Nuclear Information System (INIS)

    Gonzalez Trotter, D.E.; Meneses, F. Salinas; Tornow, W.; Howell, C.R.; Chen, Q.; Crowell, A.S.; Roper, C.D.; Walter, R.L.; Schmidt, D.; Witala, H.; Gloeckle, W.; Tang, H.; Zhou, Z.; Slaus, I.

    2006-01-01

    We report on results of a kinematically complete neutron-deuteron breakup experiment performed at Triangle Universities Nuclear Laboratory using an E n =13 MeV incident neutron beam. The 1 S 0 neutron-neutron scattering length a nn has been determined for four production angles of the neutron-neutron final-state interaction configuration. The absolute cross-section data were analyzed with rigorous three-nucleon calculations. Our average value of a nn =-18.7±0.7 fm is in excellent agreement with a nn =-18.6±0.4 fm obtained from capture experiments of negative pions on deuterons. We also performed a shape analysis of the final-state interaction cross-section enhancements by allowing the normalization of the data to float. From these relative data, we obtained an average value of a nn =-18.8±0.5 fm, in agreement with the result obtained from the absolute cross-section measurements. Our result deviates from the world average of a nn =-16.7±0.5 fm determined from previous kinematically complete neutron-deuteron breakup experiments, including the most recent one carried out at Bonn. However, this low value for a nn is at variance with theoretical expectation and other experimental information about the sign of charge-symmetry breaking of the nucleon-nucleon interaction. In agreement with theoretical predictions, no evidence was found of significant three-nucleon force effects on the neutron-neutron final-state interaction cross sections

  20. Secondary gamma-ray skyshine from 14 MeV Neutron Source Facility (OKTAVIAN). Comparison of measurement with its simulation

    Energy Technology Data Exchange (ETDEWEB)

    Morotomi, Ryutaro; Kondo, Tetsuo; Murata, Isao; Yoshida, Shigeo; Takahashi, Akito [Osaka Univ., Department of Nuclear Engineering, Suita, Osaka (Japan); Yamamoto, Takayoshi [Osaka Univ., Radio Isotope Research Center, Suita, Osaka (Japan)

    2000-03-01

    Measurement of secondary gamma-ray skyshine was performed at the Intense 14 MeV Neutron Source Facility (OKTAVIAN) of Osaka University with NaI and Hp-Ge detectors. From the result of measurements, some mechanism of secondary gamma-ray skyshine from 14 MeV neutron source facility was found out. The analysis of the measured result were carried out with MCNP-4B for four nuclear data files of JENDL-3.2, JENDL-F.F., FENDL-2, and ENDF/B-VI. It was confirmed that all the nuclear data are fairly reliable for calculations of secondary gamma-ray skyshine. (author)

  1. Inter-comparison of High Energy Files (neutron-induced, from 20 to 150 MeV)

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Young-Ouk; Fukahori, Tokio [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1998-11-01

    Recent new applications using accelerator-driven system require well-tested nuclear data when modeling the interaction of neutrons above 20 MeV. This work is aimed to review evaluation methods applied in currently available neutron high energy files above 20 to 150 MeV, to inter-compare their evaluated cross sections on some important isotopes, and to analyze resulting discrepancies. Through out these, integrities and consistencies of the high energy files are checked, applicability of physics models and evaluation methodologies are assessed, and some directions are derived to improve and expand current JENDL High Energy File. (author)

  2. Experimental techniques and theoretical models for the study of integral 14 MeV neutron cross sections

    International Nuclear Information System (INIS)

    Csikai, J.

    1981-01-01

    Owing to technical reasons, most of the data for fast neutron-induced reactions were measured at 14 MeV and the free parameters in nuclear reaction models have been determined at this energy. The discrepancies between experiment and theory are often due to the unmeasured or unreliable experimental data; therefore, it is important to survey the present techniques used for the measurement of total, elastic, nonelastic and partial nonelastic [(n,xn); (n,x charged); (n,f); (n,γ)] cross sections for 14 MeV neutrons. Systematics in the data as well as theoretical and semi-empirical models are also outlined. (author)

  3. First measurement of the VESUVIO neutron spectrum in the 30–80 MeV energy range using a Proton Recoil Telescope technique

    International Nuclear Information System (INIS)

    Cazzaniga, C; Tardocchi, M; Croci, G; Grosso, G; Rebai, M; Gorini, G; Frost, C; Rhodes, N J; Schooneveld, E M; Giacomelli, L; Hjalmarsson, A

    2013-01-01

    Measurements of the fast neutron energy spectrum at the ISIS spallation source are reported. The measurements were performed with a Proton Recoil Telescope consisting of a thin plastic foil placed in the neutron beam and two scintillator detectors. Results in the neutron energy range 30 MeV n < 80 MeV are in good agreement with Monte Carlo simulations of the neutron spectrum

  4. First measurement of the VESUVIO neutron spectrum in the 30-80 MeV energy range using a Proton Recoil Telescope technique

    Science.gov (United States)

    Cazzaniga, C.; Tardocchi, M.; Croci, G.; Frost, C.; Giacomelli, L.; Grosso, G.; Hjalmarsson, A.; Rebai, M.; Rhodes, N. J.; Schooneveld, E. M.; Gorini, G.

    2013-11-01

    Measurements of the fast neutron energy spectrum at the ISIS spallation source are reported. The measurements were performed with a Proton Recoil Telescope consisting of a thin plastic foil placed in the neutron beam and two scintillator detectors. Results in the neutron energy range 30 MeV < En < 80 MeV are in good agreement with Monte Carlo simulations of the neutron spectrum.

  5. Simulation study of neutron production in thick beryllium targets by 35 MeV and 50.5 MeV proton beams

    Science.gov (United States)

    Shin, Jae Won; Park, Tae-Sun

    2017-09-01

    A data-driven nuclear model dedicated to an accurate description of neutron productions in beryllium targets bombarded by proton beams is developed as a custom development that can be used as an add-on to GEANT4 code. The developed model, G4Data(Endf7.1), takes as inputs the total and differential cross section data of ENDF/B-VII.1 for not only the charge-exchange 9Be(p,n)9B reaction which produces discrete neutrons but also the nuclear reactions relevant for the production of continuum neutrons such as 9Be(p,pn)8Be and 9Be(p,n α) 5Li . In our benchmarking simulations for two experiments with 35 MeV and 50.5 MeV proton beams impinged on 1.16 and 1.05 cm thick beryllium targets, respectively, we find that the G4Data(Endf7.1) model can reproduce both the total amounts and the spectral shapes of the measured neutron yield data in a satisfactory manner, while all the considered hadronic models of GEANT4 cannot.

  6. Measurement of the angular distribution of 14 MeV neutrons scattered inelastically from the 0+ level at 7.65 MeV to {sup 12}C (1964); Mesure de la distribution angulaire a 14 MeV de neutrons de diffusion inelastique sur le niveau 0+ de 7,65 MeV du {sup 12}C (1964)

    Energy Technology Data Exchange (ETDEWEB)

    Szabo, I [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1963-11-15

    Inelastic scattering of 14 MeV neutrons from {sup 12}C and angular distribution for the 0{sup +} (7,65 MeV) level, with a time-of-flight spectrometer (over-all resolution 1.4 ns), gives strong forward maximum {sigma}({theta} 15 deg.) {approx_equal} 8 mb/sr suggesting a direct-interaction process. (author) [French] Realisation d'un spectrometre de neutrons rapides a temps-de-vol de resolution totale 1,4 ns. Application: {sup 12}C (n,n') {sup 12}C (7,65 MeV) donnant {sigma}{sub t} {approx_equal} 20 mb, une forte emission vers l'avant {sigma}({theta} 15 deg.) {approx_equal} 8 mb/sr indiquont un processus d'interaction directe. (auteur)

  7. High resolution inelastic gamma-ray measurements with a white neutron source from 1 to 200 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Nelson, R.O.; Laymon, C.M.; Wender, S.A.

    1990-01-01

    Measurements of prompt gamma rays following neutron-induced reactions have recently been made at the spallation neutron source at the WNR target area of LAMPF using germanium detectors. These experiments provide extensive excitation function data for inelastic neutron scattering as well as for other reactions such as (n,{alpha}), (n,n{alpha}), (n,p), (n,np), (n,nnp) and (n,xn) for 1 {le} {times} {le} 11. The continuous energy coverage available from 1 MeV to over 200 MeV is ideal for excitation function measurements and greatly extends the energy range for such data. The results of these measurements will provide a database for interpretation of gamma-ray spectra from the planned Mars Observer mission, aid in radiation transport calculations, allow verification of nuclear reaction models, and improve the evaluated neutron reaction data base.

  8. High resolution inelastic gamma-ray measurements with a white neutron source from 1 to 200 MeV

    International Nuclear Information System (INIS)

    Nelson, R.O.; Laymon, C.M.; Wender, S.A.

    1990-01-01

    Measurements of prompt gamma rays following neutron-induced reactions have recently been made at the spallation neutron source at the WNR target area of LAMPF using germanium detectors. These experiments provide extensive excitation function data for inelastic neutron scattering as well as for other reactions such as (n,α), (n,nα), (n,p), (n,np), (n,nnp) and (n,xn) for 1 ≤ x ≤ 11. The continuous energy coverage available from 1 MeV to over 200 MeV is ideal for excitation function measurements and greatly extends the energy range for such data. The results of these measurements will provide a database for interpretation of gamma-ray spectra from the planned Mars Observer mission, aid in radiation transport calculations, allow verification of nuclear reaction models, and improve the evaluated neutron reaction data base

  9. Measurement of secondary neutrons and gamma rays produced by neutron interactions in aluminum over the incident energy range 1 to 20 MeV

    International Nuclear Information System (INIS)

    Morgan, G.L.

    1975-11-01

    The spectra of secondary neutrons and gamma rays produced by neutron interaction in a thin sample (approximately 1/6 mean free path) of aluminum have been measured as a function of the incident neutron energy over the range 1 to 20 MeV. Data were taken at an angle of 125 0 . A linac (ORELA) was used as a neutron source with a 47-m flight path. Incident energy was determined by time-of-flight, while secondary spectra were determined by pulse-height unfolding techniques. The results of the measurements are presented in forms suitable for comparison to calculations based on the evaluated data files. (6 tables, 4 figures)

  10. Production of low energy gamma rays by neutron interactions with fluorine for incident neutron energies between 0.1 and 20 MeV

    International Nuclear Information System (INIS)

    Morgan, G.L.; Dickens, J.K.

    1975-06-01

    Differential cross sections for the production of low-energy gamma rays (less than 240 keV) by neutron interactions in fluorine have been measured for neutron energies between 0.1 and 20 MeV. The Oak Ridge Electron Linear Accelerator was used as the neutron source. Gamma rays were detected at 92 0 using an intrinsic germanium detector. Incident neutron energies were determined by time-of-flight techniques. Tables are presented for the production cross sections of three gamma rays having energies of 96, 110, and 197 keV. (14 figures, 3 tables) (U.S.)

  11. Neutron interrogation of actinides with a 17 MeV electron accelerator and first results from photon and neutron interrogation non-simultaneous measurements combination

    Energy Technology Data Exchange (ETDEWEB)

    Sari, A., E-mail: adrien.sari@cea.fr [CEA, LIST, Laboratoire Capteurs et Architectures Electroniques, 91191 Gif-sur-Yvette Cedex (France); Carrel, F.; Lainé, F. [CEA, LIST, Laboratoire Capteurs et Architectures Electroniques, 91191 Gif-sur-Yvette Cedex (France); Lyoussi, A. [CEA, DEN, 13108 Saint-Paul-Lez-Durance Cedex (France)

    2013-10-01

    In this article, we demonstrate the feasibility of neutron interrogation using the conversion target of a 17 MeV linear electron accelerator as a neutron generator. Signals from prompt neutrons, delayed neutrons, and delayed gamma-rays, emitted by both uranium and plutonium samples were analyzed. First results from photon and neutron interrogation non-simultaneous measurements combination are also reported in this paper. Feasibility of this technique is shown in the frame of the measurement of uranium enrichment. The latter was carried out by combining detection of prompt neutrons from thermal fission and delayed neutrons from photofission, and by combining delayed gamma-rays from thermal fission and delayed gamma-rays from photofission.

  12. Determination of the emission rate for the 14 MeV neutron generator with the use of radio-yttrium

    Directory of Open Access Journals (Sweden)

    Laszynska Ewa

    2015-06-01

    Full Text Available The neutron emission rate is a crucial parameter for most of the radiation sources that emit neutrons. In the case of large fusion devices the determination of this parameter is necessary for a proper assessment of the power release and the prediction for the neutron budget. The 14 MeV neutron generator will be used for calibration of neutron diagnostics at JET and ITER facilities. The stability of the neutron generator working parameters like emission and angular homogeneity affects the accuracy of calibration other neutron diagnostics. The aim of our experiment was to confirm the usefulness of yttrium activation method for monitoring of the neutron generator SODERN Model: GENIE 16. The reaction rate induced by neutrons inside the yttrium sample was indirectly measured by activation of the yttrium sample, and then by means of the γ-spectrometry method. The pre-calibrated HPGe detector was used to determine the yttrium radioactivity. The emissivity of neutron generator calculated on the basis of the measured radioactivity was compared with the value resulting from its electrical settings, and both of these values were found to be consistent. This allowed for a positive verification of the reaction cross section that was used to determine the reaction rate (6.45 × 10−21 reactions per second and the neutron emission rate (1.04 × 108 n·s−1. Our study confirms usefulness of the yttrium activation method for monitoring of the neutron generator.

  13. Preliminary microstructural characterization by transmission electron microscopy of 14 MeV neutron irradiated type 316 stainless steel

    International Nuclear Information System (INIS)

    Echer, C.J.

    1977-01-01

    Substantial changes in the mechanical properties of 316 stainless steel were observed after neutron irradiation (phi/sub t/ = 2.3 x 10 21 n/m 2 and E = 14 MeV) at 25 0 C. Comparison of microstructures of the unirradiated and neutron irradiated materials were evaluated using transmission electron microscopy. Evidence of small defect clusters in the irradiated material was found. These findings are consistent with other investigators also evaluating low dose irradiations

  14. Gamma-ray production cross sections for 0.9 to 20 MeV neutron interactions with 10B

    International Nuclear Information System (INIS)

    Bywater, R.L. Jr.

    1986-09-01

    Gamma-ray spectral data previously obtained at the 20-meter station of the Oak Ridge Electron Linear Accelerator flight-path 8 were studied to determine cross sections for 0.9- to 20-MeV neutron interactions with 10 B. Data reduction techniques, including those for determination of incident neutron fluences as well as those to compensate for Doppler-broadened gamma-ray-detection responses, are given in some detail in this report. 9 refs., 4 figs., 2 tabs

  15. Light charged particle production induced by fast neutrons (En=25-65 MeV) on 209Bi

    International Nuclear Information System (INIS)

    Raeymackers, Erwin; Slypen, Isabelle; Benck, Sylvie; Meulders, Jean-Pierre; Nica, Ninel; Corcalciuc, Valentin

    2002-01-01

    This paper presents the experimental set-up and data reduction procedures regarding the measurement of double-differential cross sections for light charged particle production in fast neutron induced reactions (n, px), (n, dx), (n, tx) and (n, αx) on bismuth in the incident neutron energy range 25-65 MeV and at laboratory angles from 20deg to 160deg. preliminary double-differential and energy-differential cross sections for hydrogen isotopes are presented. (author)

  16. Development and application of a detector for absolute measurement of neutron fluence rate in MeV region

    International Nuclear Information System (INIS)

    Silva Dias, M. da.

    1988-01-01

    The development and performance of the DTS (Dual Thin Scintillator) for the absolute measurement of the neutron fluence rate between 1 and 15 MeV is decribed. The DTS detector consists of a pair of organic scintillators in a dual configuration, where the incident produces a proton-recoil which is detected in a 2Π geometry therefore avoiding the effect of the escape of protons. Thin scintillators are used resulting in small multiple scattering corrections. The theoretical caluclations of detector efficiency and proton-recoil spectrum were performed by means of a Monte Carlos code - CARLO DTS. The calculated efficiency was compared to the experimental one at two neutron energies namely 2.446 MeV and 14.04 MeV applying the Time Correlated Associated Particle technique. The theoretical and experimental efficiencies agreed within the experimental uncertainties of 1.44% and 0.77%, respectively. The performance of the DTS has been verified in an absolute 235 U(n,f) cross section measurement between 1 and 6 MeV neutron energy. The cross section results were compared to those obtained replacing the DTS detector by the NBS (National Bureau of Standards, USA) Black Neutron Detector. The agreement was excellent in the overlapping energy interval of the two experiments (between 1 and 3 MeV), within the estimated uncertainly in the range of 1,0 to 1,7%. The agreement with the most recent evaluation from the ENDF/B-VI was excellent in almost all the energy range between 1 and 6 MeV. The 235 U(n,f) cross section, average over the 252 Cf fission neutron spectrum has been evaluated. The result including the cross section values of the present work was 1220 mb, in excellent agreement with the average value among the most recent measurements, 1227 +- 12 mb, and with the value 1213 mb, using the ENDF/B-VI data. (author) [pt

  17. Contribution to the determination of Sb-Ag-Cu-Ga-Mo-Zn using 14 MeV neutron activation; Contribution au dosage de Sb-Ag-Cu-Ga-Mo-Zn par activation aux neutrons de 14 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Crambes, M [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1966-04-01

    By using, 14 MeV, neutron irradiation it is possible to extend the field of application of neutron radio-activation analysis, in particular to the case of light elements. For, many other elements it can replace in-pile irradiation thereby making it possible, thanks to portable 14 MeV neutron generators, to carry out radio-activation analyses away from nuclear-research c e n t r e s. With a view to applying this analytical technique to routine work, we have developed some rapid chemical separation methods in order to make possible the determination of several elements which after exposure to fast neutrons, produce {beta} emitting nuclides which cannot be differentiated by a simple instrumental study, the emitted radiation being of the same type and of similar half-life the two cases. (author) [French] L'irradiation au moyen de neutrons de 14 MeV permet d'etendre le domaine d'application de l'analyse par radioactivation neutronique, en particulier aux elements legers. Cependant pour de nombreux autres elements elle peut remplacer l'irradiation en reacteur nucleaire permettant ainsi grace aux ensembles portables producteurs de neutrons de 14 MeV, l'extension de l'analyse par radioactivation a l'exterieur des centres d'etudes nucleaires. Dans le but d'appliquer cette methode d'analyse a des travaux de routine, nous avons mis au point des separations chimiques rapides, afin de permettre le dosage de quelques elements qui par irradiation aux neutrons rapides, engendrent des nucleides emetteurs {beta} qu'une simple etude instrumentale ne peut differencier en raison de l'identite de leur rayonnement et de leurs periodes radioactives trop proches. (auteur)

  18. Response of a carbon-walled proportional counter to 14 MeV neutrons

    International Nuclear Information System (INIS)

    Lewis, K.D.

    1982-01-01

    The response of a carbon-walled spherical proportional counter filled with a methane-based tissue-equivalent gas mixture at low pressure and irradiated with 14 MeV neutrons is first measured experimentally and is then calculated theoretically by using an analytical model. The model, called the CISS model, is derived from a consideration of four basic modes of interaction of charged particles generated in neutron-nucleus reactions with the spherical cavity of the detector. Since several quantities which have application in neutron dosimetry, radiation protection, and radiation biology make direct use of such spectra, it is desirable to have the ability to theoretically predict what is expected experimentally. Thus, a comparison between the two response curves is made. The discrepancy between them is investigated by considering several physical phenomena occurring within the detector wall which tend to distort the experimental response curve. In particular, the C(n,n',3α) reaction occurring in the detector wall gives rise to multiple events, originating from a single neutron interaction in the wall simultaneously strike the detector cavity, and are recorded as a single larger event in an experimental spectra. In the analytic model, the simultaneous entry of two charged particles into the cavity is scored as two separate smaller events, uncorrelated in their production. In this work, an effort is made to modify the analytic model prediction of the response curve by correcting for the multiple events which occur. Finally, the CISS model is used to compute mass stopping power corrections for this inhomogeneous detector

  19. Use of 14 MeV neutrons in analysis of explosive class materials

    International Nuclear Information System (INIS)

    Dighe, P.M.; Pansare, G.R.; Bhoraskar, V.N.

    1992-01-01

    Samples of explosive class materials were analised by 14 MeV neutron activation technique to estimate concentrations of oxygen, nitrogen, aluminium and chlorine. For aluminized explosives, test of stability against temperature was carried out by heating samples at 75 deg C and loss of nitrogen was studied by measuring the ratio of aluminium to nitrogen in the sample. Loss of oxygen and nitrogen in a triple base propellant heated at 71.6 deg C, was also estimated by measuring residual oxygen and nitrogen in a heated sample. This technique is convenient to adopt in the laboratory and useful to decide quickly the suitability of explosive class materials for practical applications. (author) 8 refs.; 2 figs.; 1 tab

  20. Cross-section measurements of neutron-deuteron breakup at 13.0 MeV

    International Nuclear Information System (INIS)

    Setze, H.R.; Howell, C.R.; Tornow, W.; Braun, R.T.; Gonzalez Trotter, D.E.; Hussein, A.H.; Pedroni, R.S.; Roper, C.D.; Salinas, F.; Slaus, I.; Vlahovic, B.; Walter, R.L.; Mertens, G.; Lambert, J.M.; Witala, H.; Gloeckle, W.

    2005-01-01

    Cross-section measurements of seven exit-channel configurations in the neutron-deuteron breakup at 13.0 MeV are reported and compared to rigorous calculations. Our data are consistent with those of previous measurements in four of six configurations. The present data for five configurations are in good agreement with theoretical predictions. The cross-section data for the space-star and another out-of-plane configuration are larger than the theoretical predictions by more than three standard deviations. The previously observed 20% discrepancy between theory and data for the space-star configuration is confirmed in the present work. The inclusion of the Tucson-Melbourne 2π-exchange three-nucleon force changes the predicted cross section by only 2% and in the wrong direction needed to bring theory into agreement with data

  1. Rat mammary-cell survival following irradiation with 14.3-MeV neutrons

    International Nuclear Information System (INIS)

    Mahler, P.A.; Gould, M.N.; DeLuca, P.M. Jr.; Pearson, D.W.; Clifton, K.H.

    1982-01-01

    The survival of rat mammary gland cells irradiated in situ with either single or split doses of 14.3-MeV neutrons was determined by an in vivo transplantation assay. The single-dose data are best fit to the multitarget single-hit model by the parameters D 0 = 97 cGy and n = 0.6 while the split-dose data are best fit by the parameters D 0 = 100 cGy and n = 1.2. Analysis of the combined data sets suggests that the two survival curves are not identical. Comparison of these data with previously published results following irradiation with 250-kVp x-rays is reported

  2. Benchmark experiments with 14 MeV neutrons transmitted through Pe, Fe, Ni and Al

    International Nuclear Information System (INIS)

    Tichy, M.; Kralik, M.; Pulpan, J.

    1989-01-01

    Spectra of 14 MeV neutrons transmitted through 7.6 cm of Pb, Fe, Ni and Al are presented. The target of d-t generator was placed to the center of the sphere from the tested material (outer diam. 24 cm). The detector (NE-213 scintillator diameter 5.08 cmx5.08 cm) was located at the distance 3 m and background was subtracted by means of 1 m iron cone. Measured pulse height spectra were processed by two methods and the results were compared with spectra calculated by means of the Blank and Brand codes using Endl and ENDF/B-IV libraries. Preliminary results show remarkable differences between calculation and experiment which requires additional calculations and an improvement of experimental equipment. (orig.)

  3. Effects of 14 MeV neutron irradiation on creep of nickel and niobium

    International Nuclear Information System (INIS)

    Barmore, W.; Ruotola, A.; Raymond, E.; Mukherjee, A.

    1983-01-01

    Flux, stress and temperature effects on the creep strength of nickel and niobium were observed in situ at the RTNS-II 14 MeV neutron source at Lawrence Livermore National Laboratory. Creep test were done on Ni and Nb near 0.3 Tsub(m) with stresses to 280 MPa in a high vacuum test unit using a digital computer for control and data acquisition. Cyclic flux tests produced dramatic changes in creep rate. This creep behavior is attributed to the point defect fluctuations in the crystal structure. Analysis of creep and stress relaxation under steady state flux indicates that an intermediate temperature, thermally activated deformation mechanism is rate controlling. (orig.)

  4. Rat mammary cell survival following irradiation with 14.3-MeV neutrons

    International Nuclear Information System (INIS)

    Mahler, P.A.; Gould, M.N.; DeLuca, P.M. Jr.; Pearson, D.W.; Clifton, K.H.

    1982-01-01

    The survival of rat mammary gland cells irradiated in situ with either single or split doses of 14.3-MeV neutrons was determined by an in vivo transplantation assay. The single-dose data are best fit to the multitarget single-hit model by the parameters D/sub o/ = 97 cGy and n = 0.6 while the split-dose data are best fit by the parameters D/sub o/ = 100 cGy and n = 1.2.Analysis of the combined data sets suggests that the two survival curves are not identical. Comparison of these data with previously published results following irradiation with 250-kVp X rays is reported

  5. Neutron total, scattering and inelastic gamma-ray cross sections of yttrium at few MeV energies

    International Nuclear Information System (INIS)

    Budtz-Joergensen, C.; Guenther, P.; Smith, A.; Whalen, J.; McMurray, W.R.; Renan, M.J.; Heerden, I.J. van

    1984-01-01

    Neutron total, scattering and (n; n', γ) cross sections of elemental yttrium ( 89 Y) were measured in the few-MeV region. The neutron total-cross-section measurements were made with broad resolutions from approx.=0.5 to 4.2 MeV in steps of < or approx.0.1 MeV. Neutron elastic- and inelastic-scattering cross sections were measured from approx.=1.5 to 4.0 MeV, at incident-neutron energy intervals of approx.=50 keV and at ten or more scattering angles distributed between 20 and 160 degrees using neutron detection. Inelastic-scattering cross sections were also determined using the (n; n', γ) reaction at incident energies from 1.6 to 3.8 MeV at intervals of 0.1 MeV. Gamma-rays and/or inelastically-scattered neutrons were observed corresponding to the excitation of levels at: 909.0+-0.5, 1,507.4+-0.3, 1,744.5+-0.3, 2,222.6+-0.5, 2,530+-0.8, 2,566.4+-1.0, 2,622.5+-1.0, 2,871.9+-1.5, 2,880.6+-2.0, 3,067.0+-2.0, 3,107.0+-2.0, 3,140.0+-2.0, 3,410.0+-2.0, 3,450.0+-2.0, 3,504.0+-1.5, 3,514.0+-2.0, 3,556.0+-2.0, 3,619.0+-3.0, 3,629.0+-3.0 and 3,715.0+-3.0 keV. The experimental results are discussed in terms of the spherical-optical-statistical, coupled-channels, and core-coupling models, and in the context of previously reported excited-level structure. (orig.)

  6. Experimental study on 14 MeV neutron irradiation effects in FLASH ROM28F256 and 29C256

    International Nuclear Information System (INIS)

    He Chaohui; Chen Xiaohua; Li Guozheng; Wang Yanping; Ji Lin; Geng Bin; Yang Hailiang; Liu Enke

    2000-01-01

    Experimental results of neutron irradiation effects are given for FLASH ROM. New phenomena are observed. The 14 MeV neutron irradiation effects in 28F256 and 29C256 devices are different from the single event effects. Errors are only '0'→'1'. There is a neutron flux threshold. Errors occur when neutron flux is above the threshold, no error occurs when below the threshold. The errors go up with the increase of the neutron flux until all '0' change to '1'. Hard errors, that new data cannot be written in memory with programmer, occur in devices which are measured during irradiation and irradiated in power on mode. Errors rise with the increase of reading times. Under same neutron flux, there is no error in devices in power off mode, however, errors occur in all devices in power on mode, moreover, undefined errors occur

  7. Differential neutron production cross sections and neutron yields from stopping-length targets for 113-MeV protons

    International Nuclear Information System (INIS)

    Meier, M.M.; Amian, W.B.; Clark, D.A.; Goulding, C.A.; McClelland, J.B.; Morgan, G.L.; Moss, C.E.

    1989-03-01

    We have measured differential (P,ξn) cross sections, d 2 σ/dΩdE/sub n/, from thin targets and absolute neutron yields from stopping-length targets at angles of 7.5/degree/, 30/degree/, 60/degree/, and 150/degree/, for the 113--MeV proton bombardment of elemental beryllium, carbon, aluminum, iron, and depleted uranium. Additional cross-section measurements are reported for oxygen, tungsten, and lead. We used time-of-flight techniques to identify and discriminate against backgrounds and to determine the neutron energy spectrum. Comparison of the experimental data with intranuclear-cascade evaporation-model calculations with the code HETC showed discrepancies as high as a factor of 7 in the differential cross sections. These discrepancies in the differential cross sections make it possible to identify some of the good agreement seen in the stopping-length yield comparisons as fortuitous cancellation of incorrect production estimates in different energy regimes. 13 refs., 20 figs., 4 tabs

  8. Energy dependence of fission product yields from 235U, 238U, and 239Pu with monoenergetic neutrons between thermal and 14.8 MeV

    Directory of Open Access Journals (Sweden)

    Gooden Matthew

    2017-01-01

    Full Text Available Under a joint collaboration between TUNL-LANL-LLNL, a set of absolute fission product yield measurements has been performed. The energy dependence of a number of cumulative fission product yields (FPY have been measured using quasi-monoenergetic neutron beams for three actinide targets, 235U, 238U and 239Pu, between 0.5 and 14.8 MeV. The FPYs were measured by a combination of fission counting using specially designed dual-fission chambers and γ-ray counting. Each dual-fission chamber is a back-to-back ionization chamber encasing an activation target in the center with thin deposits of the same target isotope in each chamber. This method allows for the direct measurement of the total number of fissions in the activation target with no reference to the fission cross-section, thus reducing uncertainties. γ-ray counting of the activation target was performed on well-shielded HPGe detectors over a period of two months post irradiation to properly identify fission products. Reported are absolute cumulative fission product yields for incident neutron energies of 0.5, 1.37, 2.4, 3.6, 4.6, 5.5, 7.5, 8.9 and 14.8 MeV. Preliminary results from thermal irradiations at the MIT research reactor will also be presented and compared to present data and evaluations. This work was performed under the auspices of the U.S. Department of Energy by Los Alamos National Security, LLC under contract DE-AC52-06NA25396, Lawrence Livermore National Laboratory under contract DE-AC52-07NA27344 and by Duke University and Triangle Universities Nuclear Laboratory through NNSA Stewardship Science Academic Alliance grant No. DE-FG52-09NA29465, DE-FG52-09NA29448 and Office of Nuclear Physics Grant No. DE-FG02-97ER41033.

  9. Kerma factors for neutrons of 14 MeV to 60 MeV in elemental H, C, N and O

    Energy Technology Data Exchange (ETDEWEB)

    Behrooz, M.A.; Watt, D.E. (Dundee Univ. (UK). Dept. of Medical Biophysics)

    1981-01-01

    Total kerma factors, and partial kerma factors for production of specified charged H and He particles and heavier recoils, have been computed using basic theoretical and experimental nuclear data for neutrons at energies between 14 MeV and 60 MeV in the main tissue elements and in ICRU muscle tissue. All the more recent computations of total kerma factors, along with those determined from direct experimental measurements of partial kerma factors, now form a reasonably consistent set of data enabling average total kerma factors with coefficients of better than 3% for hydrogen, 16% for carbon, 23% for nitrogen and 9% for oxygen to be recommended for application to medical dosimetry and radiation protection. Total kerma factors for ICRU muscle tissue have a precision of better than 2.5% over the neutron energy range considered. Although there is adequate precision for total kerma factors for soft tissue, nevertheless analysis of the partial kerma factors indicates that caution must be exercised in use of the information for quality specification, e.g. in microdose spectra, and that more detailed basic reaction data is required for fast neutrons.

  10. Determination of oxide film thickness on aluminium using 14-MeV neutron activation and BET method

    International Nuclear Information System (INIS)

    Foerster, H.

    1983-01-01

    A new method is described for the determination of the mean film thickness of aluminium oxides by 14-MeV neutron activation analysis of the oxygen and by BET measurement of the surface area. The mean film thickness obtained is independent of the surface roughness. Stable oxide films consisting of only a few atomic layers of oxygen are detected on aluminium. (author)

  11. Hydrogen isotope double differential production cross sections induced by 62.7 MeV neutrons on a lead target

    International Nuclear Information System (INIS)

    Kerveno, M.; Haddad, F.; Eudes, Ph.; Kirchner, T.; Lebrun, C.; Slypen, I.; Meulders, J.P.; Le Brun, C.; Lecolley, F.R.; Lecolley, J.F.; Louvel, M.; Lefebvres, F.; Hilaire, S.; Koning, A.J.

    2002-01-01

    Double differential hydrogen isotope production cross sections have been extracted in 62.7 MeV neutron induced reactions on a lead target. The angular distribution was measured at eight angles from 20 deg. to 160 deg. allowing the extraction of angle-differential, energy differential, and total production cross sections. A first set of comparisons with several theoretical calculations is also presented

  12. Measurements of 14-MeV neutron cross-sections for the production of isomeric states in hafnium isotopes

    International Nuclear Information System (INIS)

    Patrick, B.H.; Sowerby, M.G.; Wilkins, C.G.; Russen, L.C.

    1990-01-01

    The cross sections for the production of isomeric states in the reactions 179 Hf(n,2n) 178m2 Hf, 180 Hf(n,2n) 179m2 Hf, 179 Hf(n,n') 179m2 Hf with 14 MeV neutrons have been measured and compared with the theoretical ones. 4 refs, 3 figs, 4 tabs

  13. 207,208Pb(n,xnγ) reactions for neutron energies from 3 to 200 MeV

    International Nuclear Information System (INIS)

    Vonach, H.; Pavlik, A.; Chadwick, M.B.; Haight, R.C.; Nelson, R.O.; Wender, S.A.; Young, P.G.

    1994-01-01

    High-resolution γ-ray spectra from the interaction of neutrons in the energy range from 3 to 200 MeV with 207,208 Pb were measured with the white neutron source at the weapons neutron research (WNR) facility at Los Alamos National Laboratory. From these data, excitation functions for prominent γ transitions in 200,202,204,206,207,208 Pb were derived from threshold to 200 MeV incident neutron energy. These γ-production cross sections reflect the excitation cross sections for the respective residual nuclei. The results are compared with the predictions of nuclear reaction calculations based on the exciton model for precompound emission, the Hauser-Feshbach theory for compound nucleus decay, and coupled channels calculations to account for direct excitation of collective levels. Good agreement was obtained over the entire energy range covered in the experiment with reasonable model parameters. The results of this work clearly demonstrate that multiple preequilibrium emission has to be taken into account above about 40 MeV, and that the level density model of Ignatyuk, which accounts for the gradual disappearance of shell effects with increasing excitation energy, should be used instead of the Gilbert-Cameron and backshifted Fermi-gas models if excitation energies exceed about 30 MeV. No indication for a reduction of the nuclear moment of inertia below the rigid body value was found

  14. Systematics of neutron-induced fission cross sections over the energy range 0.1 through 15 MeV, and at 0.0253 eV

    International Nuclear Information System (INIS)

    Behrens, J.W.

    1977-01-01

    Recent studies have shown straightforward systematic behavior as a function of constant proton and neutron number for neutron-induced fission cross sections of the actinide elements in the incident-neutron energy range 3 to 5 MeV. In this report, the second in a series, fission cross-section values are studied over the MeV incident-neutron energy range, and at 0.0253 eV. Fission-barrier heights and neutron-binding energies are correlated by constant proton and neutron number; however, these systematic behaviors alone do not explain the trends observed in the fission cross-section values

  15. Non-elastic cross-sections for neutron interactions with carbon and oxygen above 14 MeV

    International Nuclear Information System (INIS)

    Brenner, D.J.; Prael, R.E.

    1985-01-01

    In the light of the new generation of high energy (less than or equal to 80 MeV) neutron therapy facilities currently being tested, the need for neutron kerma factors in the range from 15 to 80 MeV on carbon and oxygen has become of urgent importance. Not enough experimental data currently exist or are likely to be measured soon, so a nuclear model is essential for interpolation or, less satisfactorily, extrapolation of available data. The use of a suitable model, applicable to light nuclei, is shown to be crucial. Such a model is described, and good agreement between its results and the experimental data in the energy range of interest is reported. Comparisons between the model predictions and the ENDF/B-V evaluation of the non-elastic cross section for carbon between 15 and 20 MeV indicate that a re-evaluation of ENDF is required. 35 refs., 12 figs., 6 tabs

  16. Gamma-ray production cross sections for MeV neutrons

    International Nuclear Information System (INIS)

    Kitazawa, Hideo; Harima, Yoshiko; Yamakoshi, Hisao; Sano, Yuji; Kobayashi, Tsuguyuki.

    1979-01-01

    Gamma-ray production cross section and spectra for 1- to 20-MeV neutrons were theoretically obtained, which were requested for heating calculations, for shielding design calculations, and for material damage estimates. Calculations were carried out for Al, Si, Ca, Fe, Ni, Cu, Nb, Ta, Au, and Pb, using a spin-dependent evaporation model without the parity conservation and including the dipole and quardupole gamma-ray transitions. The results were compared with the experimental data measured in ORNL to confirm the availability of this model in applications. In addition, the effects on the gamma-ray production cross section of the optical potential, level density, yrast level, and radiation width were investigated in detail. The conclusions are: 1) the use of the optical potential which gives the correct total reaction cross section is essential to gamma-ray production calculations, 2) the gamma-ray production cross section is not so sensitive to the choice of level density parameters, 3) the inclusion of yrast levels is necessary in dealing with the competition of the neutron and gamma-ray emissions from highly excited states, and 4) the Brink-Axel type's radiation width is unsuitable to be applied to radiative capture processes. (author)

  17. A Project for High Fluence 14 MeV Neutron Source

    CERN Document Server

    Pillon, Mario; Pizzuto, Aldo; Pietropaolo, Antonino

    2014-01-01

    The international community agrees on the importance to build a large facility devoted to test and validate materials to be used in harsh neutron environments. Such a facility, proposed by ENEA , reconsiders a previous study known as “Sorgentina” but takes into account new technological development so far attained. The “New Sorgentina” Fusion Source (NSFS) project is based upon an intense D - T 14 MeV neutron source achievable with T and D ion beams impinging on 2 m radius rotating target s . NSFS produces about 1 x10 13 n cm - 2 s - 1 over about 50 cm 3 . The NSFS facility will use the ion source and accelerating system technology developed for the Positive Ion Injectors (PII) used to heat the plasma in the fusion experiments,. NSFS, to be intended as an European facility, may be realized in a few years, once provided a preliminary technological program devote to study the operation of the ion source in continuous mode, target h eat loading/ removal, target and tritium handling, inventory as well as ...

  18. Neutron-deuteron elastic scattering and breakup reactions below 20 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Howell, C.R.; Tornow, W.; Pfuetzner, H.G.; Roberts, M.L.; Murphy, K.; Felsher, P.D.; Weisel, G.J.; Mertens, G.; Walter, R.L. (Duke Univ. and Triangle Universities Nuclear Lab., Durham, NC (USA)); Lambert, J.M.; Treado, P.A. (Physics Dept., Georgetown Univ., Washington, DC (USA)); Slaus, I. (Rudjer Boskovic Inst., Zagreb (Yugoslavia))

    1991-05-01

    In this paper we review the results of a series of high-accuracy measurements on the neutron-deuteron (n-d) scattering system at incident neutron energies below 20 MeV. These measurements were designed to: 1) provide data of sufficient accuracy to be used to refine the parametrization of the nucleon-nucleon force, 2) to test the reaction dynamics in the ''rigorous'' calculations of three-nucleon (3N) breakup reactions, and 3) identify 3N scattering observables that are specifically sensitive to three-nucleus forces and/or off-shell effects. At TUNL we have measured vector analyzing powers A{sub y}({theta}) for n-d elastic scattering and the breakup reaction to an accuracy better than {+-}0.005 and {+-}0.020, respectively. Recent results on items 1) and 2) will be presented. Also, results of cross-section measurements for n-d and p-d breakup will be compared to a ''rigorous'' 3N calculation. (orig.).

  19. Neutron-deuteron elastic scattering and breakup reactions below 20 MeV

    International Nuclear Information System (INIS)

    Howell, C.R.; Tornow, W.; Pfuetzner, H.G.; Roberts, M.L.; Murphy, K.; Felsher, P.D.; Weisel, G.J.; Mertens, G.; Walter, R.L.; Lambert, J.M.; Treado, P.A.; Slaus, I.

    1991-01-01

    In this paper we review the results of a series of high-accuracy measurements on the neutron-deuteron (n-d) scattering system at incident neutron energies below 20 MeV. These measurements were designed to: 1) provide data of sufficient accuracy to be used to refine the parametrization of the nucleon-nucleon force, 2) to test the reaction dynamics in the ''rigorous'' calculations of three-nucleon (3N) breakup reactions, and 3) identify 3N scattering observables that are specifically sensitive to three-nucleus forces and/or off-shell effects. At TUNL we have measured vector analyzing powers A y (θ) for n-d elastic scattering and the breakup reaction to an accuracy better than ±0.005 and ±0.020, respectively. Recent results on items 1) and 2) will be presented. Also, results of cross-section measurements for n-d and p-d breakup will be compared to a ''rigorous'' 3N calculation. (orig.)

  20. Measured and calculated neutron yields for 100 MeV protons on thick targets of Pb and Li

    International Nuclear Information System (INIS)

    Jones, R.T.; Lone, M.A.; Okazaki, A.

    1983-01-01

    The neutron yield per proton from thick targets of lead and lithium irradiated with 100 MeV protons has been measured and calculated. The water bath method was used to measure the neutron production, and a Faraday cup for the beam current determination. Measured yields are 0.343 +- 0.021 for lead and 0.123 +- 0.007 for lithium. Corresponding yields calculated with the nucleon-meson transport code NMTC are 0.363 +- 0.002 and 0.160 +- 0.001. Measured and calculated thermal neutron distributions in the water bath are also compared

  1. Fission Product Yields of 233U, 235U, 238U and 239Pu in Fields of Thermal Neutrons, Fission Neutrons and 14.7-MeV Neutrons

    Science.gov (United States)

    Laurec, J.; Adam, A.; de Bruyne, T.; Bauge, E.; Granier, T.; Aupiais, J.; Bersillon, O.; Le Petit, G.; Authier, N.; Casoli, P.

    2010-12-01

    The yields of more than fifteen fission products have been carefully measured using radiochemical techniques, for 235U(n,f), 239Pu(n,f) in a thermal spectrum, for 233U(n,f), 235U(n,f), and 239Pu(n,f) reactions in a fission neutron spectrum, and for 233U(n,f), 235U(n,f), 238U(n,f), and 239Pu(n,f) for 14.7 MeV monoenergetic neutrons. Irradiations were performed at the EL3 reactor, at the Caliban and Prospero critical assemblies, and at the Lancelot electrostatic accelerator in CEA-Valduc. Fissions were counted in thin deposits using fission ionization chambers. The number of fission products of each species were measured by gamma spectrometry of co-located thick deposits.

  2. Measurement of neutron-production double-differential cross sections for continuous neutron-incidence reaction up to 100 MeV

    International Nuclear Information System (INIS)

    Kunieda, Satoshi; Watanabe, Takehito; Shigyo, Nobuhiro; Ishibashi, Kenji; Satoh, Daiki; Nakamura, Takashi; Haight, Robert C.

    2004-01-01

    The inclusive measurements of neutron-incident neutron-production double-differential cross sections in intermediate energy range is now being carried out. Spallation neutrons are used as incident particles. As a part of this, the experiment was performed by using of NE213 liquid organic scintillators to detect outgoing-neutrons. Incident-neutron energy was determined by time-of-flight technique, and outgoing-neutron energy spectrum was derived by unfolding light-output spectrum of NE213 with response functions calculated by SCINFUL-R. Preliminary cross sections were obtained up to about 100 MeV, and were compared with calculations by the GNASH code. It is hoped to get pure measurements by using measured response functions for our detectors used in this study. (author)

  3. Response of LR-115 type II and CR-39 plastic track detectors to Am-Be and 14.1-MeV neutrons

    International Nuclear Information System (INIS)

    Bradley, D.A.; Chong, C.S.; Saat, Ahmat; Sidik, A.G.; Ghose, A.M.

    1987-01-01

    The fast-neutron response of the plastic LR-115 type II and CR-39 track detectors have been compared, using a 14.1-MeV neutron generator and a radionuclide Am-Be neutron source (effective primary neutron energy 4.5-MeV). The distribution of track diameters for a range of etching times has been evaluated, taking into account track registration efficiency and the relevant fast neutron scattering cross-sections. The efficiency of etched-track formation in LR-115 type II due to neutron irradiation is approximately double that in CR-39. The 14.1-MeV neutrons also tend to produce tracks in both materials with somewhat greater efficiency than do the lower energy neutrons from the radionuclide source, for a given etching time. (author)

  4. Neutron radiative capture by the 241Am nucleus in the energy range 1 keV-20 MeV

    International Nuclear Information System (INIS)

    Zolotarev, K.I.; Ignatyuk, A.V.; Tolstikov, V.A.; Tertychnyj, G.Ya.

    1998-01-01

    Production of high actinides leads to many technological problems in the nuclear power. The 241 Am(n,γ) 242 Am reaction is one of the sources of high actinide buildup. So a knowledge of the radiative capture cross-section of 241 Am for neutron energies up to 20 MeV is of considerable important for present day fission reactors and future advanced reactors. The main goal of this paper is the evaluation of the excitation function for the reaction 241 Am(n,γ) 242 Am in the energy range 1 keV-20 MeV. The evaluation was done on the basis of analysed experimental data, data from theoretical model calculations and systematic predictions for 14.5 MeV and 20 MeV. Data from the present evaluation are compared with the cross-section values given in the evaluations carried out earlier. (author)

  5. Neutron spectroscopy measurements of 14 MeV neutrons at unprecedented energy resolution and implications for deuterium-tritium fusion plasma diagnostics

    Science.gov (United States)

    Rigamonti, D.; Giacomelli, L.; Gorini, G.; Nocente, M.; Rebai, M.; Tardocchi, M.; Angelone, M.; Batistoni, P.; Cufar, A.; Ghani, Z.; Jednorog, S.; Klix, A.; Laszynska, E.; Loreti, S.; Pillon, M.; Popovichev, S.; Roberts, N.; Thomas, D.; Contributors, JET

    2018-04-01

    An accurate calibration of the JET neutron diagnostics with a 14 MeV neutron generator was performed in the first half of 2017 in order to provide a reliable measurement of the fusion power during the next JET deuterium-tritium (DT) campaign. In order to meet the target accuracy, the chosen neutron generator has been fully characterized at the Neutron Metrology Laboratory of the National Physical Laboratory (NPL), Teddington, United Kingdom. The present paper describes the measurements of the neutron energy spectra obtained using a high-resolution single-crystal diamond detector (SCD). The measurements, together with a new neutron source routine ‘ad hoc’ developed for the MCNP code, allowed the complex features of the neutron energy spectra resulting from the mixed D/T beam ions interacting with the T/D target nuclei to be resolved for the first time. From the spectral analysis a quantitative estimation of the beam ion composition has been made. The unprecedented intrinsic energy resolution (<1% full width at half maximum (FWHM) at 14 MeV) of diamond detectors opens up new prospects for diagnosing DT plasmas, such as, for instance, the possibility to study non-classical slowing down of the beam ions by neutron spectroscopy on ITER.

  6. Measurement of energy deposition distributions produced in cylindrical geometry by irradiation with 15 MeV neutrons

    International Nuclear Information System (INIS)

    Brandan, M.E.

    1979-01-01

    Cellular survival experiments have shown that the biological damage induced by radiation depends on the density of energy deposition along the trajectory of the ionizing particle. The quantity L is defined to measure the density of energy transfer along a charged particle's trajectory. It is equal to sigma/l, where sigma is the energy transferred to a medium and l is the path length along which the transfer takes place. L is the stochastic quantity whose mean value is the unrestricted linear energy transfer, L/sub infinity/. Measurements of the distribution of L in a thin medium by secondary charged particles from fast neutron irradiation were undertaken. A counter operating under time coincidence between two coaxial cylindrical detectors was designed and built for this purpose. Secondary charged particles enter a gas proportional counter and deposit some energy sigma. Those particles traversing the chamber along a radial trajectory strike a CsI scintillator. A coincidence between both detectors' signals selects a known path length for these events, namely the radius of the cavity. Measurements of L distributions for l = 1 μm in tissue were obtained for 3 and 15 MeV neutron irradiation of a tissue-equivalent target wall and for 15 MeV neutron irradiation of a graphite wall. Photon events were corrected for by measurements with a Pb target wall and 15 MeV neutron irradiation as well as exposure to a pure photon field. The measured TE wall distributions with 15 MeV neutron bombardment show contributions from protons, α-particles, 9 Be and 12 C recoils. The last three comprise the L distribution for irradiation of the graphite wall. The proton component of the measured L distributions at 3 and 15 MeV was compared to calculated LET distributions

  7. Measurement of leakage neutron spectra from a spherical pile of zirconium irradiated with 14MeV neutrons and validation of its nuclear data

    CERN Document Server

    Ichihara, C; Hayashi, S A; Yamamoto, J; Takahashi, A

    2003-01-01

    In order to make a benchmark validation of the nuclear data for Zr, the leakage neutron spectrum from a Zr sphere of a 61-cm diameter was measured between 0.1 and 16MeV using a time-of-flight technique with a 14MeV neutron source facility, OKTAVIAN. The result was compared with the calculation using the Monte Carlo code MCNP-4A. To investigate the spectrum dependence on the individual neutron reactions, test calculations were carried out with the MCNP-4A code using the JENDL-3.2-based libraries, in which partial cross section values were reduced from the original values. From the comparison between the measured and the calculated spectra, it was found that each of the results could predict well the experiment in general. However, in detail, both ENDF/B-VI and EFF-2.4 gave considerable overestimation above 1 MeV. The JENDL-3.2 predicts the spectrum almost satisfactorily except below 0.8 MeV and around 10 MeV. The discrepancy found in JENDL-3.2 calculation is considered due to the cross section values of the (n...

  8. Measurement and calculation of neutron leakage spectra from slab samples of beryllium, gallium and tungsten irradiated with 14.8 MeV neutrons

    Science.gov (United States)

    Nie, Y. B.; Ruan, X. C.; Ren, J.; Zhang, S.; Han, R.; Bao, J.; Huang, H. X.; Ding, Y. Y.; Wu, H. C.; Liu, P.; Zhou, Z. Y.

    2017-09-01

    In order to make benchmark validation of the nuclear data for gallium (Ga), tungsten (W) and beryllium (Be) in existing modern evaluated nuclear data files, neutron leakage spectra in the range from 0.8 to 15 MeV from slab samples were measured by time-of-flight technique with a BC501 scintillation detector. The measurements were performed at China Institute of Atomic Energy (CIAE) using a D-T neutron source. The thicknesses of the slabs were 0.5 to 2.5 mean free path for 14.8 MeV neutrons, and the measured angles were chosen to be 60∘ and 120∘. The measured spectra were compared with those calculated by the continuous energy Monte-Carlo transport code MCNP, using the data from the CENDL-3.1, ENDF/B-VII.1 and JENDL-4.0 nuclear data files, the comparison between the experimental and calculated results show that: The results from all three libraries significantly underestimate the cross section in energy range of 10-13 MeV for Ga; For W, the calculated spectra using data from CENDL-3.1 and JENDL-4.0 libraries show larger discrepancies with the measured ones, especially around 8.5-13.5 MeV; and for Be, all the libraries led to underestimation below 3 MeV at 120∘.

  9. Attenuation data of point isotropic neutron sources up to 400MeV in water, ordinary concrete and iron

    Energy Technology Data Exchange (ETDEWEB)

    Kotegawa, Hiroshi; Tanaka, Shun-ichi; Sakamoto, Yukio; Nakane, Yoshihiro; Nakashima, Hiroshi [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1994-08-01

    A comprehensive attenuation data of dose equivalent for point isotropic monoenergetic neutron sources up to 400MeV in infinite shields of water, ordinary concrete and iron has been calculated using the ANISN-JR code and a neutron-photon multigroup macroscopic cross section HIL086R. The attenuation factors were fitted to a 4th order polynomial exponent formula, making possible to use easily for point kernel codes. Additional data in finite shielding geometry was also calculated to correct the effect due to infinite medium, giving the maximum correction of 0.23 in the region for more 400 cm distance from neutron source of 400 MeV in iron shield. Effective attenuation length for monoenergetic neutrons have been studied in detail. Subsequently, it was shown that the attenuation length was strongly dependent upon the penetration length and the Moyer`s formula using a single attenuation length brought large error into the dose estimation behind thick shields for the intermediate energy neutrons up to 400 MeV. Furthermore, it was demonstrated that there was difference more than 50 % in the attenuation length of iron between the calculations with HIL086R and HIL086 because of the self-shielding effect. (author).

  10. Determination of uranium and thorium contents using a 14 MeV neutron generator and a radiometric method

    International Nuclear Information System (INIS)

    Casagrande, J.A.

    1981-04-01

    A simple method was developed which can determine uranium and thorium in uranium ores, by 14MeV neutron activation and delayed neutron counting. The process can be used in field laboratories to select samples for processing. The method does not require a previous treatment of the samples and the analysis time is below 5 minutes. The detection limit of the method is about 2 ppm, when the yield of the 14MeV source has a value of 2 X 10 11 neutrons/second, and an optimized delayed neutron counter is used. A radiometric method is used determine separately the thorium content of the sample, and this result is combined with the activation one in order to obtain uranium content. The radiometric method in the counting of the 2,6 MeV gamma rays from 208 Tl using a NaI(Tl) detector. Delayed neutron counting is performed with BF 3 detectors inside a paraffin box. The problem of radioactive equilibrium does not affect thorium determination since the biggest activities of thorium daughters are much smaller than the times involved in the displacements of mineral which can give origin to the radioactive desequilibrium. (Author) [pt

  11. The local distribution of radiation quality of a collimated fast neutron beam from 15 MeV deuterons on beryllium

    International Nuclear Information System (INIS)

    Fidorra, J.; Booz, J.

    1978-01-01

    The local distribution of radiation quality (ysub(F), ysub(D)) of a collimated fast neutron beam from 14 MeV deuterons on Beryllium was studied with a spherical 1/2 inch EG and G proportional counter simulating a diameter of 2μm. The deuterons were accelerated by the compact cyclotron CV-28 of the Kernforschungsanlage Juelich. The collimator was constructed by the Cyclotron Corporation. The mean neutron energy was 6 MeV. The measurements were performed in air and in a water phantom at a target skin distance of 125 cm. The energy deposition spectra of fast neutrons obtained at various positions were separated into three components of different radiation quality: the gamma component, the recoil proton component, and the heavy ion component

  12. Measurement of the neutron-induced deuteron breakup reaction cross-section between 5 and 25 MeV

    International Nuclear Information System (INIS)

    Laborie, J.M.; Ledoux, X.; Varignon, C.; Lazauskas, R.; Morillon, B.; Belier, G.

    2012-01-01

    This article presents a full program devoted to the calculation and the measurement of the neutron-induced deuteron break-up reaction cross-section between 5 and 10 MeV, and between 20 and 25 MeV. Measurements are compared with theoretical calculations based on the solution of the Faddeev equations for a realistic nuclear Hamiltonian. The experiments were performed at the Tandem 7 MV accelerator at CEA, DAM, DIF, France. The measurements were carried out with a C 6 D 6 detector as active deuterium target located at the center of a 4π neutron counter (see C. Varignon et al., Nucl. Instrum. Methods B 248, 329 (2006)) which allows to count the two neutrons emitted in the 2 H(n, 2n)p reaction. Comparisons of the new data and calculations are made with the existing data as well as the CENDL2, JENDL3.3 and ENDF/B-VII evaluations. (orig.)

  13. Helium production cross section Measurement of Pb and Sn for 14.9 MeV neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Takao, Yoshiyuki; Fujimoto, Toshihiro; Ozaki, Shuji; Muramasu, Masatomo; Nakashima, Hideki [Kyushu Univ., Fukuoka (Japan); Kanda, Yukinori; Ikeda, Yujiro

    1998-03-01

    Helium production cross sections of lead and tin for 14.9 MeV neutrons were measured by helium accumulation method. Lead and tin samples were irradiated with FNS, an intense d-T neutron source of JAERI. The amount of helium produced in the samples by the neutron irradiation was measured with the Helium Atoms Measurement System (HAMS) at Kyushu University. As the samples contained a small amount of helium because of their small helium production cross sections at 14.9 MeV, the samples were evaporated by radiation from a tungsten filament to decrease background gases at helium measurement. Uncertainties of the present results were less than {+-}4.4%. The results were compared with other experimental data in the literature and also compared with the evaluated values in JENDL-3.2. (author)

  14. Fast neutron relaxation length in concretes in the range of neutron energies En=0.5 - 17.5 MeV

    International Nuclear Information System (INIS)

    Desdin, L.F.; Garcia, L.; Perez, G.; Hernandez, A.; Herrera, E.; Tellez, E.

    1998-01-01

    In the present research were determined the fast neutron relaxation length y in different type of concretes, having special interest for biological shielding as well as for ordinary construction purposes, in the energy interval of 0.5-17.5 MeV. The values of Y concrete are reported with an accuracy of 6 %

  15. Neutron tomography of axially symmetric objects using 14 MeV neutrons from a portable neutron generator

    Energy Technology Data Exchange (ETDEWEB)

    Andersson, P., E-mail: peter.andersson@physics.uu.se; Andersson-Sunden, E.; Sjöstrand, H.; Jacobsson-Svärd, S. [Department of Physics and Astronomy, Division of Applied Nuclear Physics, Uppsala University, Lägerhyddsgatan 1, 751 20 Uppsala (Sweden)

    2014-08-01

    In nuclear boiling water reactor cores, the distribution of water and steam (void) is essential for both safety and efficiency reasons. In order to enhance predictive capabilities, void distribution assessment is performed in two-phase test-loops under reactor-relevant conditions. This article proposes the novel technique of fast-neutron tomography using a portable deuterium-tritium neutron generator to determine the time-averaged void distribution in these loops. Fast neutrons have the advantage of high transmission through the metallic structures and pipes typically concealing a thermal-hydraulic test loop, while still being fairly sensitive to the water/void content. However, commercially available fast-neutron generators also have the disadvantage of a relatively low yield and fast-neutron detection also suffers from relatively low detection efficiency. Fortunately, some loops are axially symmetric, a property which can be exploited to reduce the amount of data needed for tomographic measurement, thus limiting the interrogation time needed. In this article, three axially symmetric test objects depicting a thermal-hydraulic test loop have been examined; steel pipes with outer diameter 24 mm, thickness 1.5 mm, and with three different distributions of the plastic material POM inside the pipes. Data recorded with the FANTOM fast-neutron tomography instrument have been used to perform tomographic reconstructions to assess their radial material distribution. Here, a dedicated tomographic algorithm that exploits the symmetry of these objects has been applied, which is described in the paper. Results are demonstrated in 20 rixel (radial pixel) reconstructions of the interior constitution and 2D visualization of the pipe interior is demonstrated. The local POM attenuation coefficients in the rixels were measured with errors (RMS) of 0.025, 0.020, and 0.022 cm{sup −1}, solid POM attenuation coefficient. The accuracy and precision is high enough to provide a useful

  16. Neutron tomography of axially symmetric objects using 14 MeV neutrons from a portable neutron generator.

    Science.gov (United States)

    Andersson, P; Andersson-Sunden, E; Sjöstrand, H; Jacobsson-Svärd, S

    2014-08-01

    In nuclear boiling water reactor cores, the distribution of water and steam (void) is essential for both safety and efficiency reasons. In order to enhance predictive capabilities, void distribution assessment is performed in two-phase test-loops under reactor-relevant conditions. This article proposes the novel technique of fast-neutron tomography using a portable deuterium-tritium neutron generator to determine the time-averaged void distribution in these loops. Fast neutrons have the advantage of high transmission through the metallic structures and pipes typically concealing a thermal-hydraulic test loop, while still being fairly sensitive to the water/void content. However, commercially available fast-neutron generators also have the disadvantage of a relatively low yield and fast-neutron detection also suffers from relatively low detection efficiency. Fortunately, some loops are axially symmetric, a property which can be exploited to reduce the amount of data needed for tomographic measurement, thus limiting the interrogation time needed. In this article, three axially symmetric test objects depicting a thermal-hydraulic test loop have been examined; steel pipes with outer diameter 24 mm, thickness 1.5 mm, and with three different distributions of the plastic material POM inside the pipes. Data recorded with the FANTOM fast-neutron tomography instrument have been used to perform tomographic reconstructions to assess their radial material distribution. Here, a dedicated tomographic algorithm that exploits the symmetry of these objects has been applied, which is described in the paper. Results are demonstrated in 20 rixel (radial pixel) reconstructions of the interior constitution and 2D visualization of the pipe interior is demonstrated. The local POM attenuation coefficients in the rixels were measured with errors (RMS) of 0.025, 0.020, and 0.022 cm(-1), solid POM attenuation coefficient. The accuracy and precision is high enough to provide a useful

  17. Attenuation analysis of neutrons and photons generated by 52-MeV protons transmitted through shielding materials

    International Nuclear Information System (INIS)

    Uwamino, Y.; Nakamura, T.

    1983-01-01

    Attenuation of neutrons and photons transmitted through grahite, iron, water and ordinary concrete assemblies were studied using gold foils for thermal neutron and an NE-213 organic scintillation detector with an (n-γ) discrimination technique for spectral measurements. Source neutrons and photons were produced by 52-MeV proton bombardment of a 21.4-mm-thick graphite target placed in front of the assembly. The distributions of the light output from the scintillator were unfolded by the revised FERDO code. These experimental results were used as benchmark data on neutron and photon penetration by neutrons energy above 15MeV. Multigroup Monte Carlo, one-dimensional ANISN and two-dimensional DOT-3.5 transport calculations were performed with the DLC-58/HELLO group cross sections to compare with the measurement and to evaluate the cross sections. The DOT code was also used for the estimation of room-scattered neutron and photon contribution to the measured spectra. The results of the ANISN calculation of neutrons and the three-dimensional Monte Carlo calculation agreed with the experimental values except for high energy neutrons transmitted through water and graphite. The agreement of both calculations was well within the accuracy of 7% in the measured attenuation coefficients. For photons, the ANISN calculation gave >20% overestimation of the attenuation coefficients in the case of deep penetration through the medium for which the photon mean-free-path is shorter than that of neutrons, such as in iron and concrete. The result of the DOT calculation of neutrons down to thermal energy agreed well with the gold foil measurement in the absolute value. (author)

  18. Beam dynamics study of a 30 MeV electron linear accelerator to drive a neutron source

    Science.gov (United States)

    Kumar, Sandeep; Yang, Haeryong; Kang, Heung-Sik

    2014-02-01

    An experimental neutron facility based on 32 MeV/18.47 kW electron linac has been studied by means of PARMELA simulation code. Beam dynamics study for a traveling wave constant gradient electron accelerator is carried out to reach the preferential operation parameters (E = 30 MeV, P = 18 kW, dE/E E-gun, pre-buncher, buncher, and 2 accelerating columns. A disk-loaded, on-axis-coupled, 2π/3-mode type accelerating rf cavity is considered for this linac. After numerous optimizations of linac parameters, 32 MeV beam energy is obtained at the end of the linac. As high electron energy is required to produce acceptable neutron flux. The final neutron flux is estimated to be 5 × 1011 n/cm2/s/mA. Future development will be the real design of a 30 MeV electron linac based on S band traveling wave.

  19. Dose Calibration of the ISS-RAD Fast Neutron Detector

    Science.gov (United States)

    Zeitlin, C.

    2015-01-01

    The ISS-RAD instrument has been fabricated by Southwest Research Institute and delivered to NASA for flight to the ISS in late 2015 or early 2016. ISS-RAD is essentially two instruments that share a common interface to ISS. The two instruments are the Charged Particle Detector (CPD), which is very similar to the MSL-RAD detector on Mars, and the Fast Neutron Detector (FND), which is a boron-loaded plastic scintillator with readout optimized for the 0.5 to 10 MeV energy range. As the FND is completely new, it has been necessary to develop methodology to allow it to be used to measure the neutron dose and dose equivalent. This talk will focus on the methods developed and their implementation using calibration data obtained in quasi-monoenergetic (QMN) neutron fields at the PTB facility in Braunschweig, Germany. The QMN data allow us to determine an approximate response function, from which we estimate dose and dose equivalent contributions per detected neutron as a function of the pulse height. We refer to these as the "pSv per count" curves for dose equivalent and the "pGy per count" curves for dose. The FND is required to provide a dose equivalent measurement with an accuracy of ?10% of the known value in a calibrated AmBe field. Four variants of the analysis method were developed, corresponding to two different approximations of the pSv per count curve, and two different implementations, one for real-time analysis onboard ISS and one for ground analysis. We will show that the preferred method, when applied in either real-time or ground analysis, yields good accuracy for the AmBe field. We find that the real-time algorithm is more susceptible to chance-coincidence background than is the algorithm used in ground analysis, so that the best estimates will come from the latter.

  20. Determination of phosphorus and calcium in biological samples by activation with 14 MeV neutrons

    International Nuclear Information System (INIS)

    Berretta, Jose Roberto

    1995-01-01

    Analytical methods for phosphorus and calcium in biological samples by means of activation with 14 MeV neutrons, using the Van de Graaff accelerator from the Instituto de Pesquisas Energeticas e Nucleares, SP, Brazil are developed. For phosphorus analysis, powder samples were pressed into pellets, weighed and transferred to polyethylene plastic envelopes. The pellets with cadmium shielding were irradiated under a fast neutron flux for 5 to 10 minutes, and further counted in a HPGe detector for 5 minutes. Calcium analysis was performed by cyclic irradiation. Samples were irradiated for 10 minutes. After a decay time of 2 minutes, gamma counting was performed for 10 minutes. After a decay time of 2 minutes, a new irradiation ws made. The irradiation cycle was repeated 5 times and the counting spectrum obtained in each cycle was accumulated in the multi channel analyser. The variation of the neutron flux was followed by using a BF 3 detector calibrated with and aluminium monitor. By means of the gamma spectrum and the neutron counting of the BF 3 detector it was possible to estimate phosphorus and calcium concentrations in the sample analyzed. The methods were checked in the reference samples from the International Atomic Energy Agency and in commercial samples of powder milk, fertilizer and animal bone. Phosphorus contents in bone (A3/74) and milk (A-11) reference materials were (15.6 +- 1.8%) and (0.9 +- 0.1)%, respectively. These values are in good agreement to the certified values (15.5 +- 0.5)% and (0.910 +- 0.102)%, respectively. Calcium analysis carried out in bone (A3/74) presented a value of (31.8+-4.1)% and the certified value was of (31.3 +- 0.3)%. Detection limits for phosphorus and calcium were determined in different analyzed samples. The agreement of the results obtained with the certified values confirmed the suitability of the methods for phosphorus and calcium analysis. The methods are fast and laborious chemical procedures are not required. (author)

  1. Production of neutrons up to 18 MeV in high-intensity, short-pulse laser matter interactions

    Energy Technology Data Exchange (ETDEWEB)

    Higginson, D. P. [Mechanical and Aerospace Engineering, University of California-San Diego, La Jolla, California 92093 (United States); Lawrence Livermore National Laboratory, Livermore, California 94440 (United States); McNaney, J. M.; Swift, D. C.; Mackinnon, A. J.; Patel, P. K. [Lawrence Livermore National Laboratory, Livermore, California 94440 (United States); Petrov, G. M.; Davis, J. [Naval Research Laboratory, Plasma Physics Division, Washington, DC 20375 (United States); Frenje, J. A. [Plasma Science and Fusion Center, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139 (United States); Jarrott, L. C.; Tynan, G.; Beg, F. N. [Mechanical and Aerospace Engineering, University of California-San Diego, La Jolla, California 92093 (United States); Kodama, R.; Nakamura, H. [Institute of Laser Engineering, Osaka University, 2-5 Yamada-oka, Suita, Osaka 454-0871 (Japan); Lancaster, K. L. [STFC Rutherford Appleton Laboratory, Chilton, Oxon OX11OQX (United Kingdom)

    2011-10-15

    The generation of high-energy neutrons using laser-accelerated ions is demonstrated experimentally using the Titan laser with 360 J of laser energy in a 9 ps pulse. In this technique, a short-pulse, high-energy laser accelerates deuterons from a CD{sub 2} foil. These are incident on a LiF foil and subsequently create high energy neutrons through the {sup 7}Li(d,xn) nuclear reaction (Q = 15 MeV). Radiochromic film and a Thomson parabola ion-spectrometer were used to diagnose the laser accelerated deuterons and protons. Conversion efficiency into protons was 0.5%, an order of magnitude greater than into deuterons. Maximum neutron energy was shown to be angularly dependent with up to 18 MeV neutrons observed in the forward direction using neutron time-of-flight spectrometry. Absolutely calibrated CR-39 detected spectrally integrated neutron fluence of up to 8 x 10{sup 8} n sr{sup -1} in the forward direction.

  2. Model calculation of neutron reaction data for 31P in the energy range from 0.1 to 20 MeV

    International Nuclear Information System (INIS)

    Li Jiangting; Ge Zhigang; Sun Xiuquan

    2006-01-01

    The neutron data calculation of 31 P in the energy range from 0.1 to 20 MeV was carried out. The neutron optical potential parameters for 31 P in energy range from O.1 to 20 MeV were obtained, based on the fitting of the available neutron experimental data with the code APOM94. The DWUCK4 code was used to investigate the cross section for neutron direct inelastic scattering. The re-evaluated neutron data is based on the available measured data by using the UNF code. The theoretical results reproduce the experimental data well, and the results were given in ENDF/B-6 format. (authors)

  3. Measurements of hydrogen and helium isotopes emission spectra from neutrons induced reaction at ten's of MeV

    International Nuclear Information System (INIS)

    Nauchi, Yasushi; Baba, Mamoru; Hirasawa, Yoshitaka

    1999-01-01

    We have developed a wide dynamic range spectrometer for the measurements of (n, xZ) double differential cross sections (DDXs) for ten's of MeV neutrons at TIARA. The spectrometer consists of a 40-cm diameter vacuum reaction chamber and three counter telescopes. Each telescope consists of a gas proportional counter, an SSD and a BaF 2 scintillator. By using the spectrometer, we achieved simultaneous measurements from ∼MeV α particles to 75 MeV protons with an acceptable counting rate. (author)

  4. 1500-MeV fixed-field alternating-gradient synchrotron for a pulsed-spallation neutron source

    International Nuclear Information System (INIS)

    Kustom, R.L.; Khoe, T.K.; Crosbie, E.A.

    1985-01-01

    The first conceptual design of the FFAG for ASPUN was an 1100-MeV, 20-sector machine with an injection radius of 17.5 m and an extraction radius of 18.75 m. The conceptual design currently under study has a higher extraction energy, a larger average radius, but still has 20 sectors. The current interest in higher extraction energy is stimulated by calculations that indicate that the useful neutron production per incident proton is still increasing proportionally up to 1500 MeV. The larger radius also matches existing buildings at Argonne that could be made available for the facility. 11 refs., 4 figs., 3 tabs

  5. Measurement of secondary neutron emission double-differential cross sections for {sup 9}Be induced by 21.65 ± 0.07 MeV neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Lan, Changlin [School of Nuclear Science & Technology, Lanzhou University, Lanzhou 730000 (China); Ruan, Xichao; Chen, Guochang; Nie, Yangbo; Huang, Hanxiong; Bao, Jie; Zhou, Zuying; Tang, Hongqing [Department of Nuclear Physics, China Institute of Atomic Energy, Beijing 102413 (China); Kong, Xiangzhong; Peng, Meng [School of Nuclear Science & Technology, Lanzhou University, Lanzhou 730000 (China)

    2016-05-15

    The neutron emission double-differential cross sections (DDX) of {sup 9}Be was measured at an incident neutron energy of 21.65 MeV, using the multi-detector fast neutron time-of-flight (TOF) spectrometer on HI-13 Tandem Accelerator at the China Institute of Atomic Energy (CIAE). The data were deduced by comparing the measured TOF spectra with the calculated ones using a realistic Monte-Carlo simulation. The DDX were normalized to n–p scattering cross sections which are a neutron scattering standard. The results of the elastic scattering angular distributions (DX) and the secondary neutron emission DDX at 25 different angles from 15 deg to 145 deg were presented. Meanwhile, a theoretical model based on the unified Hauser-Feshbach and exciton model for light nuclei was used to describe the double-differential cross sections of n+{sup 9}Be, and the theoretical calculation results were compared with the measured cross sections.

  6. Fast-neutron gamma-ray production from elemental iron: E/sub n/ approx. < 2 MeV

    International Nuclear Information System (INIS)

    Smith, D.L.

    1976-05-01

    A Ge(Li) detector and a fission detector were used to measure elemental differential cross section excitation functions for fast neutron gamma-ray production from iron relative to fast neutron fission of 235 U. Data were acquired at approximately 50 keV intervals with approximately 50 keV neutron-energy resolution from near threshold to approximately 2 MeV. Angular distributions for the 0.847 MeV gamma ray were measured at 0.93, 0.98, 1.08, 1.18, 1.28, 1.38, 1.59, 1.68, 1.79, 1.85 and 2.03 MeV. Significant fourth-order terms were required for the Legendre polynomial expansions used in fitting several of these angular distributions. This casts doubt on the accuracy of the commonly used approximation that the integrated gamma-ray production cross section is essentially equal to 4π times the 55 0 (or 125 0 ) differential cross section. The method employed in processing these data is described. Comparison is made between results from the present work and some previously reported data sets. The uncertainties associated with energy scales, neutron-energy resolution and other experimental factors for these various measurements make it difficult to draw conclusions concerning the observed differences in the values reported for these fluctuating cross sections. 6 tables, 7 figures

  7. Fast-neutron gamma-ray production from elemental iron: E/sub n/ < or approx. = 2 MeV

    International Nuclear Information System (INIS)

    Smith, D.L.

    1976-05-01

    A Ge(Li) detector and a fission detector were used to measure elemental differential cross section excitation functions for fast-neutron gamma-ray production from iron relative to fast-neutron fission of 235 U. Data were acquired at approximately 50 keV intervals with approximately 50 keV neutron-energy resolution from near threshold to approximately 2 MeV. Angular distributions for the 0.847-MeV gamma ray were measured at 0.93, 0.98, 1.08, 1.18, 1.28, 1.38, 1.59, 1.68, 1.79, 1.85 and 2.03 MeV. Significant fourth-order terms were required for the Legendre polynomial expansions used in fitting several of these angular distributions. This casts doubt on the accuracy of the commonly used approximation that the integrated gamma-ray production cross section is essentially equal to 4π times the 55-degree (or 125-degree) differential cross section. The method employed in processing these data is described. Comparison is made between results from the present work and some previously reported data sets. The uncertainties associated with energy scales, neutron-energy resolution and other experimental factors for these various measurements make it difficult to draw conclusions concerning the observed differences in the values reported for these fluctuating cross sections

  8. The shielding performance of multilayer composite shielding structures to 14.8 MeV fast neutrons

    International Nuclear Information System (INIS)

    Shen Zhiqiang; Kang Qing; Xu Jun; Wang Zhenggang; Lu Nan

    2014-01-01

    Cement-based round thin-layer samples mixed with 30% quality content of barite, and 20% quality content of carbide boron has Prepared, the same-diameter sliced samples of pure graphite and pure polyethylene has cut, then, samples combination and cross stack order has designed, formed four species Multilayer Composite shield structure, at last, neutron attenuation measurements has been done by experimental system of using 14.8 MeV neutrons from the 5SDH-2 accelerator and long counter composition, penetrating rate of samples and the shield structure to 14.8 MeV fast neutron has tested, and attenuation section has calculated. Results show that 14.8 MeV fast neutrons to higher penetration rates of thin layer samples, attenuation cross section of samples distinguish small between each other, must be increasing the thickness of the samples to reduce the experimental uncertainty; through composed of attenuation cross section and thickness parameters of composite structure, can more accurately predict the shielding ability of composite structures, error between calculation results and experimental results in 4%. (authors)

  9. Measurement of neutron-induced fission cross-sections of Th232, U238, U233 and Np237 relative to U235 from 1 MeV to 200 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Shcherbakov, O.A.; Laptev, A.B.; Petrov, G.A. [Petersburg Nuclear Physics Inst., Gatchina, Leningrad district (Russian Federation); Fomichev, A.V.; Donets, A.Y.; Osetrov, O.I.

    1998-11-01

    The measurements of neutron-induced cross-section ratios for Th232, U238, U233 and Np237 relative to U235 have been carried out in the energy range from 1 MeV up to 200 MeV using the neutron time-of-flight spectrometer GNEIS based on 1 GeV proton synchrocyclotron. Below 20 MeV, the results of present measurements are roughly in agreement with evaluated data though there are some discrepances to be resolved. (author)

  10. Estimation of uncertainties of displacement cross-sections for iron and tungsten at neutron irradiation energies above 0.1 MeV

    International Nuclear Information System (INIS)

    Konobeyev, A.Yu.; Fischer, U.; Simakov, S.P.

    2016-01-01

    The goal of this work is the evaluation of uncertainties of calculated atomic displacement cross sections for iron and tungsten irradiated with neutrons. Uncertainties were analysed for neutron incident energies above 0.1 MeV, which make the main contribution to the value of radiation damage rate for different types of nuclear or fusion reactors and neutron sources

  11. Kinetic energy spectrum and polarization of neutrons from the reaction 12C(p,n)X at 590 MeV

    International Nuclear Information System (INIS)

    Arnold, J.

    1998-01-01

    The kinetic energy spectrum and the polarization of the PSI neutron beam produced in the reaction 12 C(p,n)X at 0 with 590 MeV polarized protons were investigated. A strong energy dependence of the neutron beam polarization is observed which was not expected at the time the neutron beam was built. (orig.)

  12. Contribution to the study of the inelastic scattering of neutrons from a to 5 MeV (1961); Contribution a l'etude de la diffusion inelastique des neutrons de 1 a 5 MeV (1961)

    Energy Technology Data Exchange (ETDEWEB)

    Abramson - Szteinsznaider, D [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1961-07-01

    - The aim of this work is to see if this reaction occurs only by compound nucleus formation or involves some contribution of direct interaction. In the first case, the angular distribution of inelastic neutrons is symmetric about 90 degree. In the second case, this distribution must be asymmetric and must change slowly with energy of incident neutrons. The neutrons corresponding at the excitation of a given level of the residual nucleus are selected by their coincidence with the {gamma} rays of deexcitation of this level. From the results of our measurements on iron, iodine and bismuth and of other laboratories on different elements, we can conclude that generally, the inelastic scattering of neutrons of some MeV occurs only by compound nucleus. (author) [French] - Le but de ce travail est de determiner si cette reaction s'effectue uniquement par passage par un noyau compose ou fait intervenir un processus d'interaction directe. Dans le premier cas, la distribution angulaire des neutrons inelastiques est symetrique par rapport a 90 degree. Dans le deuxieme cas, cette distribution doit etre asymetrique et doit varier lentement avec l'energie des neutrons incidents. Les neutrons correspondant a l'excitation d'un niveau determine du residuel sont selectionnes par leur cofncidence avec les rayonnements {gamma} de desexcitation de ce niveau. D'apres les resultats de nos mesures sur le fer, l'iode et le bismuth et de celles des autres laboratoires sur differents elements, nous pouvons conclure que, en general, la diffusion inelastique des neutrons de quelques MeV s'effectue uniquement par noyau compose. (auteur)

  13. Double-differential beryllium neutron cross sections at incident neutron energies of 5. 9, 10. 1, and 14. 2 MeV. [5. 9 to 14. 2 MeV, differential cross sections, ENDF/B-IV

    Energy Technology Data Exchange (ETDEWEB)

    Drake, D.M.; Auchampaugh, G.F.; Arthur, E.D.; Ragan, C.E.; Young, P.G.

    1976-08-01

    Beryllium neutron-production cross sections were measured using the time-of-flight technique at incident neutron energies of 5.9, 10.1, and 14.2 MeV, and at laboratory angles of 25, 27.5, 30, 35, 45, 60, 80, 100, 110, 125, and 145/sup 0/. The differential elastic and inelastic cross sections are presented. Inelastic is defined here as those reactions that proceed through the states at 1.69-, 2.43-, 2.8-, and 3.06-MeV excitation energy in /sup 9/Be. Comparison of emission energy spectra with calculations using the ENDF/B-IV beryllium cross sections shows that the ENDF/B cross sections strongly overemphasize the low lying states in /sup 9/Be.

  14. The thick-target 9Be(d,n) neutron spectra for deuteron energies between 2.6 and 7.0-MeV

    International Nuclear Information System (INIS)

    Meadows, J.W.

    1991-11-01

    The measurement of the zero deg. neutron spectra and yields from deuterons incident on thick beryllium metal targets is described. 235 U and 238 U fission ion chambers were used as neutron detectors to span the neutron energy range above 0.05-MeV with a time resolution of ≤ 3 nanosec. Measurements were made for incident deuteron energies from 2.6 to 7.0-MeV, at 0.4-MeV intervals, using time-of-flight techniques with flight paths of 2.7 and 6.8 meters. The results are presented in graphical form and in tables

  15. Measurement of the energy spectrum with proportional counters with spherical cathodes between 20 keV and 2.5 MeV with the propagation of 14 MeV neutrons in liquid nitrogen and liquid air

    International Nuclear Information System (INIS)

    Schneider-Kuehnle, P.

    1974-01-01

    This work deals with the measurement of the energy spectrum of a 14 MeV neutron source in liquid nitrogen and liquid air in the energy region of 20 keV to 2.5 MeV as a function of the distance from the source. The measured results together with those of a scintispectrometer which measures the energies between 2.5 MeV and 14 MeV, are to serve as experimentally-supported input data for shielding calculations and are to enable the checking of transport theoretical calculations. (orig./LH) [de

  16. Emission of γ rays from various materials pulsed with 14-MeV neutrons

    International Nuclear Information System (INIS)

    Goldberg, E.; Hansen, L.F.; Howerton, R.J.; Komoto, T.T.; Pohl, B.A.

    1987-10-01

    We have performed a number of experiments at LLNL recently to investigate the leakage of gamma rays from spheres of selected materials pulsed centrally with 14-MeV neutrons. Such spectral information may be carefully compared to calculational results to validate the transport models, particularly the nuclear cross section data base. In the present case, the TART code and SANDYL codes are used to explicitly calculate the observable, the recoil electron spectrum. The materials studied were H 2 O, 6 LiD, Be, C, 14 N, CF 2 , Al, Si, Ti, Fe, Cu, Ta, W, Au, Pb, Th, and 238 U. Generally, agreement was good between experiment and calculation. However, for some, the calculations significantly underestimated or overestimated experiment. For oxygen (i.e., H 2 O), the ENDL cross section set led to a sizeable calculational overestimate. Re-examination led to a large improvement. For tungsten, the calculated output was ∼30% below experiment. A re-evaluation led to closer agreement. 16 refs., 10 figs., 1 tab

  17. Charged pion production from neutron--proton collisions at 790 MeV

    International Nuclear Information System (INIS)

    Thomas, W.R.

    1977-09-01

    The two reactions np → nnπ + and np → ppπ - were studied at 790 MeV (incident neutron energy). Pion spectra were measured at 10 different angles with a multiwire proportional chamber spectrometer. Approximately 100,000 events were analyzed. The angular distribution of pions in the np center of momentum system (d sigma/dΩ*) was given by [(123.1 +- 2.7) + (88.3 +- 4.9)cos 2 (theta*)](μb/sr). The cross section sigma(np → NNπ/sup +-/) was determined to be 1.92 +- .20 mb by integrating (d sigma/dΩ*) over all angles. The partial cross section for pion production from T = 0 np interactions (sigma 01 ) was found to be .1/sub -.1//sup +.5/ mb by using the relation sigma 01 = 2sigma(np → NNπ/sup +-)--sigma(pp → ppπ 0 ). Stronger indications of nonresonant pion production were given by the presence of asymmetries between the positive and negative pion spectra and a comparison of the data with an isobar model calculation

  18. Cross section measurements of the (n,2n) reaction with 14 MeV neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Kaji, Harumi; Shiokawa, Takanobu [Tohoku Univ., Sendai (Japan). Faculty of Science; Suehiro, Teruo; Yagi, Masuo

    1975-07-01

    Cross sections are measured for the reactions /sup 64/Zn(n, 2n)/sup 63/Zn, /sup 75/As(n, 2n)/sup 74/As, /sup 79/Br(n, 2n)/sup 78/Br, /sup 90/Zr(n, 2n)/sup 89/Zr, /sup 141/Pr(n, 2n)/sup 140/Pr and /sup 144/Sm(n, 2n)/sup 143/Sm by activation method in the energy range 13.5-14.8 MeV. The cross sections are determined relatively to the cross section for the /sup 63/Cu(n, 2n)/sup 62/Cu and /sup 19/F(n, 2n)/sup 18/F reactions. Before the cross section measurement, incident-neutron energies are measured by recoil proton method. The results of the cross sections are compared with data existing in the literatures and are discussed with reference to the theory of Weisskopf and Ewing.

  19. Variance reduction techniques for 14 MeV neutron streaming problem in rectangular annular bent duct

    Energy Technology Data Exchange (ETDEWEB)

    Ueki, Kotaro [Ship Research Inst., Mitaka, Tokyo (Japan)

    1998-03-01

    Monte Carlo method is the powerful technique for solving wide range of radiation transport problems. Its features are that it can solve the Boltzmann`s transport equation almost without approximation, and that the complexity of the systems to be treated rarely becomes a problem. However, the Monte Carlo calculation is always accompanied by statistical errors called variance. In shielding calculation, standard deviation or fractional standard deviation (FSD) is used frequently. The expression of the FSD is shown. Radiation shielding problems are roughly divided into transmission through deep layer and streaming problem. In the streaming problem, the large difference in the weight depending on the history of particles makes the FSD of Monte Carlo calculation worse. The streaming experiment in the 14 MeV neutron rectangular annular bent duct, which is the typical streaming bench mark experiment carried out of the OKTAVIAN of Osaka University, was analyzed by MCNP 4B, and the reduction of variance or FSD was attempted. The experimental system is shown. The analysis model by MCNP 4B, the input data and the results of analysis are reported, and the comparison with the experimental results was examined. (K.I.)

  20. [International Panel on 14 MeV Intense Neutron Source Based on Accelerators for Fusion Materials Study

    International Nuclear Information System (INIS)

    Thoms, K.R.; Wiffen, F.W.

    1991-01-01

    Both travelers were members of a nine-person US delegation that participated in an international workshop on accelerator-based 14 MeV neutron sources for fusion materials research hosted by the University of Tokyo. Presentations made at the workshop reviewed the technology developed by the FMIT Project, advances in accelerator technology, and proposed concepts for neutron sources. One traveler then participated in the initial meeting of the IEA Working Group on High Energy, High Flux Neutron Sources in which efforts were begun to evaluate and compare proposed neutron sources; the Fourth FFTF/MOTA Experimenters' Workshop which covered planning and coordination of the US-Japan collaboration using the FFTF reactor to irradiate fusion reactor materials; and held discussions with several JAERI personnel on the US-Japan collaboration on fusion reactor materials

  1. Evaluation and benchmarking of nuclear data of vanadium in integral experiments with 14-MeV neutrons

    CERN Document Server

    Blokhin, A I; Chuvilin, D; Livke, A V; Manokhin, V N; Markovskij, D; Nagorny, V; Nefedov, Yu A; Orlov, R; Savin, M; Semenov, V; Shmarov, A; Shvetsov, A M; Zagryadsky, V; Zhitnik, A

    2001-01-01

    The measurements of the gamma-ray and neutron leakage spectra from three vanadium spheres with diameter 10, 24 and 34 cm at their internal irradiation by 14-MeV neutrons were carried out in frame of the ISTC Project no. 910 in collaboration with FZK. All the spheres have the same geometry of the central hole of 3 cm in diameter. The neutron leakage spectra were measured by a scintillation detector, and by a gas proportional counter. The gamma-ray leakage spectra were measured with help of a crystal NaI(Tl). Analysis of these experiments is performed with the new evaluated nuclear data files prepared in frame of the project activities. A comparison of experimental and calculated neutron and gamma-ray leakage spectra from three vanadium spheres is given.

  2. Neutron induced 238U subthreshold fission cross section for neutron energies between 5 eV and 3.5 MeV

    International Nuclear Information System (INIS)

    Perez, R.B.; Difilippo, F.C.; Saussure, G. de; Ingle, R.W.

    1978-01-01

    A measurement of the 238 U fission cross section between 5 eV and 3.5 MeV was performed. Included is the identification of 85 resonances or clusters of resonances below 200 keV. Also the fission widths for the 27 resolved class I levels were computed from their fission areas, and a neutron width of 0.005 MeV was estimated for the quasi-class II level in the 721 eV fission cluster. The fission level spacing and cross sections are discussed. 9 references

  3. Measurement of neutron spectra generated from bombardment of 4 to 24 MeV protons on a thick 9Be target and estimation of neutron yields

    International Nuclear Information System (INIS)

    Paul, Sabyasachi; Sahoo, G. S.; Tripathy, S. P.; Sunil, C.; Bandyopadhyay, T.; Sharma, S. C.; Ramjilal,; Ninawe, N. G.; Gupta, A. K.

    2014-01-01

    A systematic study on the measurement of neutron spectra emitted from the interaction of protons of various energies with a thick beryllium target has been carried out. The measurements were carried out in the forward direction (at 0° with respect to the direction of protons) using CR-39 detectors. The doses were estimated using the in-house image analyzing program autoTRAK-n, which works on the principle of luminosity variation in and around the track boundaries. A total of six different proton energies starting from 4 MeV to 24 MeV with an energy gap of 4 MeV were chosen for the study of the neutron yields and the estimation of doses. Nearly, 92% of the recoil tracks developed after chemical etching were circular in nature, but the size distributions of the recoil tracks were not found to be linearly dependent on the projectile energy. The neutron yield and dose values were found to be increasing linearly with increasing projectile energies. The response of CR-39 detector was also investigated at different beam currents at two different proton energies. A linear increase of neutron yield with beam current was observed

  4. Relativistically Induced Transparency Acceleration (RITA) - laser-plasma accelerated quasi-monoenergetic GeV ion-beams with existing lasers?

    Science.gov (United States)

    Sahai, Aakash A.

    2013-10-01

    Laser-plasma ion accelerators have the potential to produce beams with unprecedented characteristics of ultra-short bunch lengths (100s of fs) and high bunch-charge (1010 particles) over acceleration length of about 100 microns. However, creating and controlling mono-energetic bunches while accelerating to high-energies has been a challenge. If high-energy mono-energetic beams can be demonstrated with minimal post-processing, laser (ω0)-plasma (ωpe) ion accelerators may be used in a wide-range of applications such as cancer hadron-therapy, medical isotope production, neutron generation, radiography and high-energy density science. Here we demonstrate using analysis and simulations that using relativistic intensity laser-pulses and heavy-ion (Mi ×me) targets doped with a proton (or light-ion) species (mp ×me) of trace density (at least an order of magnitude below the cold critical density) we can scale up the energy of quasi-mono-energetically accelerated proton (or light-ion) beams while controlling their energy, charge and energy spectrum. This is achieved by controlling the laser propagation into an overdense (ω0 RITA). Desired proton or light-ion energies can be achieved by controlling the velocity of the snowplow, which is shown to scale inversely with the rise-time of the laser (higher energies for shorter pulses) and directly with the scale-length of the plasma density gradient. Similar acceleration can be produced by controlling the increase of the laser frequency (Chirp Induced Transparency Acceleration, ChITA). Work supported by the National Science Foundation under NSF- PHY-0936278. Also, NSF-PHY-0936266 and NSF-PHY-0903039; the US Department of Energy under DEFC02-07ER41500, DE- FG02-92ER40727 and DE-FG52-09NA29552.

  5. The Efficiency of the BC-720 Scintillator in a High-Energy (20--800 MeV) Accelerator Neutron Field

    Energy Technology Data Exchange (ETDEWEB)

    Miles, Leslie H. [Univ. of Missouri, Columbia, MO (United States)

    2005-12-01

    High-energy neutron doses (>20 MeV) are of little importance to most radiation workers. However, space and flight crews, and people working around medical and scientific accelerators receive over half of their radiation dose from high-energy neutrons. Unfortunately, neutrons are difficult to measure, and no suitable dosimetry has yet been developed to measure this radiation. In this paper, basic high-energy neutron interactions, characteristics of high-energy neutron environments, present neutron dosimetry, and quantities used in neutron dosimetry are discussed before looking into the potential of the BC-720 scintillator to improve dosimetry. This research utilized 800 MeV protons impinging upon the WNR Facility spallation neutron source at Los Alamos National Laboratory. Time-of-flight methods and a U-238 Fission Chamber were used to aid evaluation of the efficiency of the BC-720. Results showed that the efficiency is finite over the 20–650 MeV energy region studied, although it decreases by a factor of ten between 40 and 100 MeV. This limits the use of this dosimeter to measure doses at sitespecific locations. It also encourages modifications to use this dosimeter for any unknown neutron field. As such, this dosimeter has the potential for a small, lightweight, real-time dose measurement, which could impact neutron dosimetry in all high-energy neutron environments.

  6. Measurement of cross sections for the scattering of neutrons in the energy range from 2 MeV to 4 MeV with the {sup 15}N(p,n) reaction as neutron source; Messung von Wirkungsquerschnitten fuer die Streuung von Neutronen im Energiebereich von 2 MeV bis 4 MeV mit der {sup 15}N(p,n)-Reaktion als Neutronenquelle

    Energy Technology Data Exchange (ETDEWEB)

    Poenitz, Erik

    2010-04-26

    In future nuclear facilities, the materials lead and bismuth can play a more important role than in today's nuclear reactors. Reliable cross section data are required for the design of those facilities. In particular the neutron transport in the lead spallation target of an Accelerator-Driven Subcritical Reactor strongly depends on the inelastic neutron scattering cross sections in the energy region from 0.5 MeV to 6 MeV. In the recent 20 years, elastic and inelastic neutron scattering cross sections were measured with high precision for a variety of elements at the PTB time-of-flight spectrometer. The D(d,n) reaction was primarily used for the production of neutrons. Because of the Q value of the reaction and the available deuteron energies, neutrons in the energy range from 6 MeV to 16 MeV can be produced. For the cross section measurement at lower energies, however, another neutron producing reaction is required. The {sup 15}N(p,n){sup 15}O reaction was chosen, as it allows the production of monoenergetic neutrons with up to 5.7MeV energy. In this work, the {sup 15}N(p,n) reaction was studied with focus on the suitability as a source for monoenergetic neutrons in scattering experiments. This includes the measurement of differential cross sections for the neutron producing reaction and the choice of optimum target conditions. Differential elastic and inelastic neutron scattering cross sections were measured for lead at four energies in the region from 2 MeV to 4 MeV incident neutron energy using the time-of-flight technique. A lead sample with natural isotopic composition was used. NE213 liquid scintillation detectors with well-known detection efficiencies were used for the detection of the scattered neutrons. Angle-integrated cross sections were determined by a Legendre polynomial expansion using least-squares methods. Additionally, measurements were carried out for isotopically pure {sup 209}Bi and {sup 181}Ta samples at 4 MeV incident neutron energy

  7. The 2.5-MeV neutron time-of-flight spectrometer TOFOR for experiments at JET

    International Nuclear Information System (INIS)

    Gatu Johnson, M.; Giacomelli, L.; Hjalmarsson, A.

    2007-08-01

    A time-of-flight (TOF) spectrometer for measurement of the 2.5-MeV neutron emission from fusion plasmas has been developed and put into use at the JET tokamak. It has been optimized for operation at high rates (TOFOR) for the purpose of performing advanced neutron emission spectroscopy (NES) diagnosis of deuterium plasmas with a focus on the fuel ion motional states for different auxiliary heating scenarios. This requires operation over a large dynamic range including high rates of >100 kHz with a maximum value of 0.5 MHz for the TOFOR design. This paper describes the design principles and their technical realization. The performance is illustrated with recent neutron time-of-flight spectra recorded for plasmas subjected to different heating scenarios. A data acquisition rate of 39 kHz has been achieved at about a tenth of the expected neutron yield limit of JET, giving a projected maximum of 400 kHz at peak JET plasma yield. This means that the count rate capability for NES diagnosis of D plasmas has been improved more than an order of magnitude. Another important performance factor is the spectrometer bandwidth where data have been acquired and analyzed successfully with a response function for neutrons over the energy range 1 to >5 MeV. The implications of instrumental advancement represented by TOFOR are discussed

  8. The 2.5-MeV neutron time-of-flight spectrometer TOFOR for experiments at JET

    International Nuclear Information System (INIS)

    Gatu Johnson, M.; Giacomelli, L.; Hjalmarsson, A.; Kaellne, J.; Weiszflog, M.; Andersson Sunden, E.; Conroy, S.; Ericsson, G.; Hellesen, C.; Ronchi, E.; Sjoestrand, H.; Gorini, G.; Tardocchi, M.; Combo, A.; Cruz, N.; Sousa, J.; Popovichev, S.

    2008-01-01

    A time-of-flight (TOF) spectrometer for measurement of the 2.5-MeV neutron emission from fusion plasmas has been developed and put into use at the JET tokamak. It has been optimized for operation at high rates (TOFOR) for the purpose of performing advanced neutron emission spectroscopy (NES) diagnosis of deuterium plasmas with a focus on the fuel ion motional states for different auxiliary heating scenarios. This requires operation over a large dynamic range, including high rates of >100 kHz with a maximum value of 0.5 MHz for the TOFOR design. This paper describes the design principles and their technical realization. The performance is illustrated with recent neutron TOF spectra recorded for plasmas subjected to different heating scenarios. A true event count rate of 39 kHz has been achieved at about a tenth of the expected neutron yield limit of JET, giving a projected maximum of 400 kHz at peak JET plasma yield. This means that the count rate capability for NES diagnosis of D plasmas has been improved more than an order of magnitude. Another important performance factor is the spectrometer bandwidth, where data have been acquired and analyzed successfully with a response function for neutrons over the energy range 1 to >5 MeV. The implications of instrumental advancement represented by TOFOR are discussed

  9. The 2.5-MeV neutron time-of-flight spectrometer TOFOR for experiments at JET

    Energy Technology Data Exchange (ETDEWEB)

    Gatu Johnson, M.; Giacomelli, L.; Hjalmarsson, A. (and others)

    2007-08-15

    A time-of-flight (TOF) spectrometer for measurement of the 2.5-MeV neutron emission from fusion plasmas has been developed and put into use at the JET tokamak. It has been optimized for operation at high rates (TOFOR) for the purpose of performing advanced neutron emission spectroscopy (NES) diagnosis of deuterium plasmas with a focus on the fuel ion motional states for different auxiliary heating scenarios. This requires operation over a large dynamic range including high rates of >100 kHz with a maximum value of 0.5 MHz for the TOFOR design. This paper describes the design principles and their technical realization. The performance is illustrated with recent neutron time-of-flight spectra recorded for plasmas subjected to different heating scenarios. A data acquisition rate of 39 kHz has been achieved at about a tenth of the expected neutron yield limit of JET, giving a projected maximum of 400 kHz at peak JET plasma yield. This means that the count rate capability for NES diagnosis of D plasmas has been improved more than an order of magnitude. Another important performance factor is the spectrometer bandwidth where data have been acquired and analyzed successfully with a response function for neutrons over the energy range 1 to >5 MeV. The implications of instrumental advancement represented by TOFOR are discussed.

  10. Quantitative comparison between experimental and simulated gamma-ray spectra induced by 14 MeV tagged neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Perot, B., E-mail: bertrand.perot@cea.fr [CEA, DEN, Cadarache, Nuclear Measurement Laboratory, F-13108 Saint-Paul-lez-Durance (France); El Kanawati, W.; Carasco, C.; Eleon, C. [CEA, DEN, Cadarache, Nuclear Measurement Laboratory, F-13108 Saint-Paul-lez-Durance (France); Valkovic, V. [A.C.T.d.o.o., Prilesje 4, 10000 Zagreb (Croatia); Sudac, D.; Obhodas, J. [Ruder Boskovic Institute, Bijenicka c. 54, 10000 Zagreb (Croatia); Sannie, G. [CEA, LIST, Saclay, F-91191 Gif-sur-Yvette (France)

    2012-07-15

    Fast neutron interrogation with the associated particle technique can be used to identify explosives in cargo containers (EURITRACK FP6 project) and unexploded ordnance on the seabed (UNCOSS FP7 project), by detecting gamma radiations induced by 14 MeV neutrons produced in the {sup 2}H({sup 3}H,{alpha})n reaction. The origin of the gamma rays can be determined in 3D by the detection of the alpha particle, which provides the direction of the opposite neutron and its time-of-flight. Gamma spectroscopy provides the relative counts of carbon, nitrogen, and oxygen, which are converted to chemical fractions to differentiate explosives from other organic substances. To this aim, Monte Carlo calculations are used to take into account neutron moderation and gamma attenuation in cargo materials or seawater. This paper presents an experimental verification that C, N, and O counts are correctly reproduced by numerical simulation. A quantitative comparison is also reported for silicon, iron, lead, and aluminium. - Highlights: Black-Right-Pointing-Pointer Gamma-ray spectra produced by 14 MeV neutrons in C, N, O, Si, Al, Fe, and Pb elements. Black-Right-Pointing-Pointer Quantitative comparison with MCNPX simulations using the ENDF/B-VII.0 library. Black-Right-Pointing-Pointer C, N, and O counts correctly reproduced and chemical proportions recovered using calculation. Black-Right-Pointing-Pointer Application to the detection of explosives or illicit drugs in cargo containers.

  11. Measurement of the uranium-235 fission cross section over the neutron energy range 1 to 6 MeV

    International Nuclear Information System (INIS)

    Barton, D.M.; Diven, B.C.; Hansen, G.E.; Jarvis, G.A.; Koontz, P.G.; Smith, R.K.

    1976-01-01

    The ratio of the fission cross section of 235 U to the scattering cross section of 1 H was measured in the 1- to 6-MeV range using monoenergetic neutrons from a pulsed 3 H(p,n) 3 He source. In this measurement, solid-state detectors determined fission fragment and recoil proton emissions from back-to-back U(99.7%) and polyethylene disks. Timing permitted discrimination against room-scattered neutron backgrounds. Absolute values for 235 U(n,f) are obtained using the Hopkins-Breit evaluation of the hydrogen-scattering cross section

  12. Neutron-proton analyzing power at 12 MeV and inconsistencies in parametrizations of nucleon-nucleon data

    OpenAIRE

    Braun, R. T.; Tornow, W.; Howell, C. R.; Trotter, D. E. Gonzalez; Roper, C. D.; Salinas, F.; Setze, H. R.; Walter, R. L.; Weisel, G. J.

    2008-01-01

    We present the most accurate and complete data set for the analyzing power Ay(theta) in neutron-proton scattering. The experimental data were corrected for the effects of multiple scattering, both in the center detector and in the neutron detectors. The final data at En = 12.0 MeV deviate considerably from the predictions of nucleon-nucleon phase-shift analyses and potential models. The impact of the new data on the value of the charged pion-nucleon coupling constant is discussed in a model s...

  13. Neutron-proton analyzing power at 12 MeV and inconsistencies in parametrizations of nucleon-nucleon data

    Energy Technology Data Exchange (ETDEWEB)

    Braun, R.T. [Department of Physics, Duke University, Durham, NC 27708-0308 (United States); Triangle Universities Nuclear Laboratory, Durham, NC 27708-0308 (United States); Tornow, W. [Department of Physics, Duke University, Durham, NC 27708-0308 (United States); Triangle Universities Nuclear Laboratory, Durham, NC 27708-0308 (United States)], E-mail: tornow@tunl.duke.edu; Howell, C.R.; Gonzalez Trotter, D.E.; Roper, C.D.; Salinas, F.; Setze, H.R.; Walter, R.L. [Department of Physics, Duke University, Durham, NC 27708-0308 (United States); Triangle Universities Nuclear Laboratory, Durham, NC 27708-0308 (United States); Weisel, G.J. [Department of Physics, Penn State Altoona, Altoona, PA 16601 (United States)

    2008-02-21

    We present the most accurate and complete data set for the analyzing power A{sub y}({theta}) in neutron-proton scattering. The experimental data were corrected for the effects of multiple scattering, both in the center detector and in the neutron detectors. The final data at E{sub n}=12.0 MeV deviate considerably from the predictions of nucleon-nucleon phase-shift analyses and potential models. The impact of the new data on the value of the charged pion-nucleon coupling constant is discussed in a model study.

  14. Neutron-proton analyzing power at 12 MeV and inconsistencies in parametrizations of nucleon-nucleon data

    International Nuclear Information System (INIS)

    Braun, R.T.; Tornow, W.; Howell, C.R.; Gonzalez Trotter, D.E.; Roper, C.D.; Salinas, F.; Setze, H.R.; Walter, R.L.; Weisel, G.J.

    2008-01-01

    We present the most accurate and complete data set for the analyzing power A y (θ) in neutron-proton scattering. The experimental data were corrected for the effects of multiple scattering, both in the center detector and in the neutron detectors. The final data at E n =12.0 MeV deviate considerably from the predictions of nucleon-nucleon phase-shift analyses and potential models. The impact of the new data on the value of the charged pion-nucleon coupling constant is discussed in a model study

  15. The analyzing power Asub(y)(theta) for the elastic scattering of 12 MeV neutrons from deuterons

    International Nuclear Information System (INIS)

    Tornow, W.; Lisowski, P.W.; Byrd, R.C.; Walter, R.L.

    1978-01-01

    The analyzing power Asub(y)(theta) was obtained at 10 0 intervals between 30 0 (lab) to 120 0 (lab) for 2 H(n, n) 2 H at 12.0 MeV. The polarized neutron beam employed in the measurement was obtained by using neutrons emitted at 0 0 from the polarization transfer reaction 2 H(d(pol), n(pol)) 3 He. The accuracy in the Asub(y)(theta) values that was achieved ranged from +- 0.006 to +- 0.013. Comparison of the data to Asub(y)(theta) results obtained at 12 MeV for the charge symmetric reaction 2 H(p, p) 2 H shows that the two Asub(y)(theta) distributions are equal to within the above accuracy. (Auth.)

  16. 54Fe neutron elastic and inelastic scattering differential cross sections from 2-6 MeV

    Science.gov (United States)

    Vanhoy, J. R.; Liu, S. H.; Hicks, S. F.; Combs, B. M.; Crider, B. P.; French, A. J.; Garza, E. A.; Harrison, T.; Henderson, S. L.; Howard, T. J.; McEllistrem, M. T.; Nigam, S.; Pecha, R. L.; Peters, E. E.; Prados-Estévez, F. M.; Ramirez, A. P. D.; Rice, B. G.; Ross, T. J.; Santonil, Z. C.; Sidwell, L. C.; Steves, J. L.; Thompson, B. K.; Yates, S. W.

    2018-04-01

    Measurements of neutron elastic and inelastic scattering cross sections from 54Fe were performed for nine incident neutron energies between 2 and 6 MeV. Measured differential scattering cross sections are compared to those from previous measurements and the ENDF, JENDL, and JEFF data evaluations. TALYS calculations were performed and modifications of the default parameters are found to better describe the experimental cross sections. A spherical optical model treatment is generally adequate to describe the cross sections in this energy region; however, in 54Fe the direct coupling is found to increase suddenly above 4 MeV and requires an increase in the DWBA deformation parameter by approximately 25%. This has little effect on the elastic scattering differential cross sections but makes a significant improvement in both the strength and shape of the inelastic scattering angular distribution, which are found to be very sensitive to the size and extent of the surface absorption region.

  17. Study of a solid state micro-dosemeter based on a monolithic silicon telescope: Irradiations with low-energy neutrons and direct comparison with a cylindrical TEPC

    International Nuclear Information System (INIS)

    Agosteo, S.; Colautti, P.; Fanton, I.; Fazzi, A.; Introini, M. V.; Moro, D.; Pola, A.; Varoli, V.

    2011-01-01

    A silicon device based on the monolithic silicon telescope technology coupled to a tissue-equivalent converter was proposed and investigated for solid state microdosimetry. The detector is constituted by a DE stage about 2 μm in thickness geometrically segmented in a matrix of micrometric diodes and a residual-energy measurement stage E about 500 μm in thickness. Each thin diode has a cylindrical sensitive volume 9 μm in nominal diameter, similar to that of a cylindrical tissue-equivalent proportional counter (TEPC). The silicon device and a cylindrical TEPC were irradiated in the same experimental conditions with quasi-monoenergetic neutrons of energy between 0.64 and 2.3 MeV at the INFN-Legnaro National Laboratories (LNLINFN, Legnaro (Italy)). The aim was to study the capability of the silicon-based system of reproducing microdosimetric spectra similar to those measured by a reference micro-dosemeter. The TEPC was set in order to simulate a tissue site about 2 μm in diameter. The spectra of the energy imparted to the ΔE stage of the silicon telescope were corrected for tissue-equivalence through an optimized procedure that exploits the information from the residual energy measurement stage E. A geometrical correction based on parametric criteria for shape-equivalence was also applied. The agreement between the dose distributions of lineal energy and the corresponding mean values is satisfactory at each neutron energy considered. (authors)

  18. Calculation of neutron monitor reaction cross sections of {sup 90}Zr in energy region up to 100 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Qingbiao, Shen; Baosheng, Yu; Dunjiu, Cai [Chinese Nuclear Data Center, Beijing, BJ (China)

    1996-06-01

    Many nuclear data for n + {sup 90}Zr reaction were calculated by using optical model evaporation model and exciton model. The program SPEC, including the first to the sixth particle emission processes, was used in our calculations. The calculated results show that the activation products {sup 89,88}Zr and {sup 88,87}Y are important neutron monitor reaction products for n + {sup 90}Zr reaction in energy range up to 100 MeV. (4 figs.).

  19. Neutron scattering on natural iron at incident energies between 9.4 and 15.2 MeV

    International Nuclear Information System (INIS)

    Schmidt, D.; Mannhart, W.; Klein, H.; Nolte, R.

    1994-11-01

    Neutrons were scattered on a sample of natural iron at 12 incident energies in the range between 9.4 MeV and 15.2 MeV. Differential cross sections of the elastic scattering (natural iron) and of the inelastic scattering to the first excited level of 56 Fe (Q=-0.847 MeV) were determined for angles between 12.5 deg and 160 deg with total uncertainties between of 3% and 10%. Legendre polynomial least-squares fits resulted in integrated cross sections with uncertainties of 2% (elastic data) and 7% (inelastic data). The cross sections obtained in this work were compared with data from the literature. Inelastic scattering cross sections were determined within the scope of a pseudolevel analysis up to excitation energies of nearly 5.5 MeV. At higher excitation energies the scattering spectrum is contaminated by scattered breakup neutrons from the D+d source used hampering an analysis of the data. (orig.) [de

  20. /sup 1/H(t,n)/sup 3/He reaction as monoenergetic neutron source in the (10/20) MeV energy interval

    Energy Technology Data Exchange (ETDEWEB)

    Zago, G. (Padua Univ. (Italy). Ist. di Fisica; Istituto Nazionale di Fisica Nucleare, Padua (Italy))

    1981-11-14

    This article examines the problem of finding a neutron source in the (10/20) MeV energy interval, having convenient properties for controlled thermonuclear-fusion researches and biomedical applications.

  1. Measurement and analysis of 14 MeV neutron-induced double-differential neutron emission cross sections needed for fission and fusion reactor technology

    International Nuclear Information System (INIS)

    Wang Dahai; Mehta, M.K.

    1988-07-01

    The main objectives of this IAEA Co-ordinated Research Programme are to improve the current status of data for 14 MeV neutron-induced double-differential neutron emission cross sections for V, Cr, Fe, Nb, Ta and 238 U. The principal objectives of this first meeting were to report on the status of participants' work, to exchange experience in experimental work and to establish the future work. Considering the unsatisfactory status of the data for 6 Li, 7 Li, 9 Be, Mo, W and Bi and their importance in fusion reactor technology participants agreed to include these isotopes in the programme

  2. A study of Venus surface elemental composition from 14 MeV neutron induced gamma ray spectroscopy: Activation analysis

    International Nuclear Information System (INIS)

    Jun, I.; Kim, W.; Smith, M.; Mitrofanov, I.; Litvak, M.

    2011-01-01

    The surface elemental composition of Venus can be determined using an artificially pulsed 14 MeV neutron generator (PNG) combined with a gamma ray spectrometer (GRS). The 14 MeV neutrons will interact with the surface materials and generate gamma rays, characteristic of specific elements, whose energy spectrum will be measured by GRS. These characteristic gamma rays are produced mainly through 3 different neutron interaction mechanisms: capture, inelastic, and activation reactions. Each reaction type has a different neutron energy dependency and different time scale for gamma ray production and transport. Certain elements are more easily identified through one reaction type over the others. Thus, careful analysis of the gamma ray spectra during and after the neutron pulse provides a comprehensive understanding of the surface elemental composition. In this paper, we use a well-tested neutron/gamma transport code, called Monte Carlo N-Particles (MCNP), to investigate the measurement capability of a PNG-GRS detection system through the neutron activation reactions. An activation analysis was performed for a representative soil composition of Venus with a notional operational scenario of PNG and GRS. The analysis shows that the proposed instrument concept can identify most of the modeled surface elements at Venus with sufficient accuracy through the activation mode. Specifically, U, Th, K, Si can be measured to within 1%, Fe within 2%, Al within 10%, Ca within 5%, Mg with 15%, Mn with 20%, and Cl within 6%. Although modeled in the analysis, it is shown that the activation mode alone cannot distinguish the S and Ti peaks.

  3. Energy dependence of relative abundances and periods of delayed neutron separate groups from neutron induced fission of 239Pu in the virgin neutron energy range 0.37-4.97 MeV

    International Nuclear Information System (INIS)

    Piksajkin, V.M.; Kazakov, L.E.; Isaev, S.T.; Korolev, G.G.; Roshchenko, V.A.; Tertychnyj, R.G.

    2002-01-01

    Relative yield and group period of delayed neutrons induced by the 239 Pu fission in the 0.37-4.97 MeV range were measured. Comparative analysis of experimental data was conducted in terms of middle period of half-life of delayed neutron nuclei-precursors. Character and scale of changing values of delayed neutron group parameters as changing excitation energy of fission compound-nucleus have been demonstrated for the first time. Considerable energy dependence of group parameters under the neutron induced 239 Pu fission that was expressed by the decreasing middle period of half-life of nuclei-precursors by 10 % in the 2.85 eV - 5 MeV range of virgin neutrons was detected [ru

  4. Survival of germinal cells of the male rat after exposure to 14 and 50 MeV neutrons and R.B.E

    International Nuclear Information System (INIS)

    Lemaire, Guy; Grillon, Gerard; Ricourt, Alain.

    1977-10-01

    No significant differences could be demonstrated between male rat germinal cell survivals to 14MeV and up to 50 MeV neutrons respectively. The survivals are well fitted by an exponential model (D 0 =289 rads) logically situated between the models concerning 60 Co gamma rays and fission neutrons. On the basis of the testes weight loss after irradiation, the experimental results gave EBR ranging from 10 to 1.3 for survival rates from 92 to 2% [fr

  5. Ambiguities in the elastic scattering of 8 MeV neutrons from adjacent nuclei

    International Nuclear Information System (INIS)

    Smith, A.B.; Lawson, R.D.; Guenther, P.T.

    1989-10-01

    Ratios of the cross sections for elastic scattering of 8 MeV neutrons from adjacent nuclei are measured over the angular range ∼20 degree - 160 degree for the target pairs 51 V/Cr, 59 Co/ 58 Ni, Cu/Zn, 89 Y/ 93 Nb, 89 Y/Zr, 93 Nb/Zr, In/Cd and 209 Bi/Pb. The observed ratios vary from unity by as much as a factor of ∼2 at some angles for the lighter target pairs. Approximately half the measured ratios are reasonably explained by a simple spherical optical model, including size and isospin contributions. In all cases, the geometry of the real optical--model potential is essentially the same for neighboring nuclei, and the real--potential strengths are consistent with the Lane model. In contrast, it is found that the imaginary potential may be quite different for adjacent nuclei, and the nature of this difference is examined. It is shown that the spin--spin interaction has a negligible effect on the calculation of the elastic--scattering ratios, but that channel coupling, leading to a large reorientation of the target ground state, can be a consideration, particularly in the 59 Co/ 58 Ni case. In the A ∼ 50--60 region the calculated ratios are sensitive to spin--orbit effects, but the exact nature of this interaction must await more definitive polarization measurements. The measured and calculated results suggest that the concept of a conventional ''global'' or even ''regional'' optical potential provides no more than a qualitative representation of the physical reality for a number of cases. 48 refs., 14 figs., 3 tabs

  6. Ambiguities in the elastic scattering of 8 MeV neutrons from adjacent nuclei

    Energy Technology Data Exchange (ETDEWEB)

    Smith, A.B.; Lawson, R.D.; Guenther, P.T.

    1989-10-01

    Ratios of the cross sections for elastic scattering of 8 MeV neutrons from adjacent nuclei are measured over the angular range {approx}20{degree} {minus} 160{degree} for the target pairs {sup 51}V/Cr, {sup 59}Co/{sup 58}Ni, Cu/Zn, {sup 89}Y/{sup 93}Nb, {sup 89}Y/Zr, {sup 93}Nb/Zr, In/Cd and {sup 209}Bi/Pb. The observed ratios vary from unity by as much as a factor of {approx}2 at some angles for the lighter target pairs. Approximately half the measured ratios are reasonably explained by a simple spherical optical model, including size and isospin contributions. In all cases, the geometry of the real optical--model potential is essentially the same for neighboring nuclei, and the real--potential strengths are consistent with the Lane model. In contrast, it is found that the imaginary potential may be quite different for adjacent nuclei, and the nature of this difference is examined. It is shown that the spin--spin interaction has a negligible effect on the calculation of the elastic--scattering ratios, but that channel coupling, leading to a large reorientation of the target ground state, can be a consideration, particularly in the {sup 59}Co/{sup 58}Ni case. In the A {approx} 50--60 region the calculated ratios are sensitive to spin--orbit effects, but the exact nature of this interaction must await more definitive polarization measurements. The measured and calculated results suggest that the concept of a conventional global'' or even regional'' optical potential provides no more than a qualitative representation of the physical reality for a number of cases. 48 refs., 14 figs., 3 tabs.

  7. Neutron fluence in a 18 MeV Electron Accelerator for Therapy; Fluencia de neutrones en un Acelerador de Electrones de 18 MeV para terapia

    Energy Technology Data Exchange (ETDEWEB)

    Paredes G, L C [Instituto Nacional de Investigaciones Nucleares, Direccion de Innovacion Tecnologica, A.P. 18-1027, 11801 Mexico D.F. (Mexico)

    2001-07-01

    An investigation was made on the theoretical fundamentals for the determination of the neutron fluence in a linear electron accelerator for radiotherapy applications and the limit values of leakage neutron radiation established by guidelines and standards in radiation protection for these type of accelerators. This investigation includes the following parts: a) Exhaustive bibliographical review on the topics mentioned above, in order to combine and to update the necessary basic information to facilitate the understanding of this subject; b) Analysis of the accelerator operation and identification of its main components, specially in the accelerator head; c) Study of different types of targets and its materials for the Bremsstrahlung production which is based on the electron initial energy, the thickness of the target, and its angular distribution and energy, which influences in the neutron generation by means of the photonuclear and electro disintegration reactions; d) Analysis of the neutron yield based on the target type and its thickness, the energy of electrons and photons; e) Analysis of the neutron energy spectra generated in the accelerator head, inside and outside the treatment room; f) Study of the dosimetry fundamentals for neutron and photon mixed fields, the dosimeter selection criteria and standards applied for these applications, specially the Panasonic U D-809 thermoluminescent dosemeter and C R-39 nuclear track dosimeter; g) Theoretical calculation of the neutron yield using a simplified geometric model for the accelerator head with spherical cell, which considers the target, primary collimator, flattener filter, movable collimators and the head shielding as the main components for radiation production. The cases with W and Pb shielding for closed movable collimators and an irradiation field of 20 x 20 cm{sup 2} were analyzed and, h) Experimental evaluation of the leakage neutron radiation from the patient and head planes, observing that the

  8. Standard Test Method for Oxygen Content Using a 14-MeV Neutron Activation and Direct-Counting Technique

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2007-01-01

    1.1 This test method covers the measurement of oxygen concentration in almost any matrix by using a 14-MeV neutron activation and direct-counting technique. Essentially, the same system may be used to determine oxygen concentrations ranging from over 50 % to about 10 g/g, or less, depending on the sample size and available 14-MeV neutron fluence rates. Note 1 - The range of analysis may be extended by using higher neutron fluence rates, larger samples, and higher counting efficiency detectors. 1.2 This test method may be used on either solid or liquid samples, provided that they can be made to conform in size, shape, and macroscopic density during irradiation and counting to a standard sample of known oxygen content. Several variants of this method have been described in the technical literature. A monograph is available which provides a comprehensive description of the principles of activation analysis using a neutron generator (1). 1.3 The values stated in either SI or inch-pound units are to be regarded...

  9. Preparation of 3-7 MeV neutron source and preliminary results of activation cross section measurement

    Energy Technology Data Exchange (ETDEWEB)

    Furuta, T.; Masuda, T.; Tsurita, Y.; Hashimoto, A.; Miyajima, N. [Department of Nuclear Engineering, Nagoya University, Nagoya, Aichi (Japan); Sakane, H.; Shibata, M.; Yamamoto, H.; Kawade, K.

    1999-03-01

    A d-D gas target producing monoenergetic neutrons has been constructed for measurement of activation cross sections in the energy region of 3 to 7 MeV at Van de Graaff accelerator of Nagoya University. Neutron spectra and neutron fluxes were measured as a function of the incident deuteron energy. Preliminary results of activation cross sections were obtained for reactions {sup 27}Al(n, p){sup 27}Mg, {sup 27}Al(n, {alpha}){sup 24}Na, {sup 47}Ti(n, p){sup 47}Sc, {sup 56}Fe(n, p){sup 56}Mn, {sup 58}Ni(n, p){sup 58}Co and {sup 64}Zn(n, p){sup 64}Cu. The results are compared with the evaluated values of JENDL-3.2. A well-type HPGe detector was used for highly efficient detection. (author)

  10. Neutron yield of thick {sup 12}C and {sup 13}C targets with 20 and 30 MeV deuterons

    Energy Technology Data Exchange (ETDEWEB)

    Lhersonneau, G.; Fadil, M. [GANIL, Caen (France); Malkiewicz, T. [CSC - IT Center for Science Ltd., Espoo (Finland); Gorelov, D.; Sorri, J.; Trzaska, W.H. [University of Jyvaskyla, Department of Physics, Jyvaskyla (Finland); Jones, P.; Ngcobo, P.Z. [iThemba Laboratory for Accelerator Based Science, Western Cape (South Africa)

    2016-12-15

    The neutron yield of thick targets of carbon, natural and enriched in {sup 13}C, bombarded by deuterons of 20 and 30 MeV has been measured by the activation method. The gain with respect to a {sup 12}C target is the same as with protons beams. The yield ratio is about 1.2 only and hardly can justify the use of a {sup 13}C target with deuteron beams. The data, apart from being of interest for the design of facilities where secondary neutron beams are used, provide a test case for calculations where both beam and target have a weakly bound neutron. The MCNPx code version 2.6.0, despite failing to reproduce some details of the experimental distributions, describes their global properties fairly well, especially the relative yields of the {sup 12}C and {sup 13}C targets. (orig.)

  11. Cross sections and differential spectra for reactions of 2-20 MeV neutrons on /sup nat/Cr

    International Nuclear Information System (INIS)

    Blann, M.; Komoto, T.T.

    1988-01-01

    This report summarizes product yields, secondary n,p and α spectra, and γ-ray spectra calculated for incident neutrons of 2 to 20 MeV on /sup nat/Cr targets. Results are all from the code ALICE, using the version ALISO which does weighting of results for targets which are a mix of isotopes. Where natural isotopic targets are involved, yields and n,p,α spectra will be reported weighted over isotopic yields. Gamma-ray spectra, however, will be reported for the most abundant isotope. We present product yields versus incident neutron energy, n,p,α spectra versus incident neutron energy, and calculated γ-ray spectra

  12. Study of the flux attenuation and energy degradation of 14.8 MeV neutrons in different materials

    International Nuclear Information System (INIS)

    Boufraqech, A.

    1981-01-01

    The attenuation of 14.8 MeV neutrons has been determined using the 63-Cu(n,2n)62-Cu threshold reaction for the detection of the primary neutrons. The attenuation of primary flux in different materials can be well described by a simple exponential relation based on the removal cross section. The microscopic removal cross sections determined for graphite, aluminium, iron and lead are as follows 0.73 +- 0.04, 1.04 +-0.04, 1.41 +- 0.02 and 2.63 +- 0.12 barn respectively. The dependance of secondary neutron spectrum on the thickness of slabs has also been investigated by threshold detectors. 15 refs., 38 figs., 23 tabs. (author)

  13. Mammary carcinogenesis induced by three consecutive 14 MeV neutron irradiations in Sprague-Dawley rats

    International Nuclear Information System (INIS)

    Jacrot, M.; Mouriquand, J.; Mouriquand, C.

    1978-01-01

    At high doses (400 to 800 rads) the relative biological effectiveness (R.B.E.) of neutrons is two or three times greater than that of X-rays or gamma radiation. The neutron irradiation-induced mammary carcinogenesis threshold, if any, is certainly very low in Sprague-Dawley females. The purpose of this work is to test the possibilities offered by three consecutive 14 MeV neutron irradiations in the mammary carcinogenesis region of Sprague-Dawley rats. The results of these experiments show a hormone-dependence of tumour promotion similar to that observed with chemical carcinogenetic agents. However these tumours, by their recurrences and possible metastases, bear some resemblance to breast cancers in women. Although the tumour induction frequencies seem modest in relation to those obtained with the DMBA model they should nevertheless prove very useful in the study of hormone effects liable to control the appearance of such radioinduced cancers [fr

  14. Fission product yields from 6 to 9 MeV neutron induced fission of 235U and 238U

    International Nuclear Information System (INIS)

    Chapman, T.C.

    1978-01-01

    The yields of 28 mass chains have been measured for fission of 235 U and 238 U induced by neutrons at four different energies from 6.0 to 9.1 MeV. This is the first experimental measurement where sufficient energy resolution was obtained to observe the effect of the onset of second-chance fission in the case of symmetric fission. The 111 Ag results are compared with measurements at other neutron energies and with previous theoretical predictions. Several of the nuclide results are presented in graphical form, and all nuclide results are presented in tabular form, as a function of neutron energy. The mass chains measured range from 84 to 156, and their half-lives range from 18 minutes to 30 years

  15. Recovery of the spermatogenetic epithelium in the mouse after irradiation with 1-MeV fission neutrons

    International Nuclear Information System (INIS)

    Aardweg, G.J.M.J. van den.

    1983-01-01

    In this thesis the recovery of the spermatogenetic epithelium in the mouse is studied after damage with 1-MeV fission neutrons. A severe depletion of A-spermatogonia and radiosensitive stem cells occurs after neutron irradiation. Recovery of the epithelium is initiated by surviving radioresistant stem cells giving rise to colonies, which grow into the empty seminiferous tubules. After discussing properties of normal and irradiated spermatogenetic epithelium, the growth and the differentiation of spermatogenetic colonies in the mouse testis after irradiation, as well as response and kinetics of colony-forming spermatogonial stem cells in CBA mice up to 30 weeks after a first neutron dose and recovery of the epithelium after a second irradiation are investigated. These four subjects are dealt with in separate papers. Finally, a discussion and a summary of these studies is presented. (Auth.)

  16. Production cross section measurement of discrete gammas-ray at 90 degree for interactions of 14. 9 MeV neutrons with carbon and niobium

    Energy Technology Data Exchange (ETDEWEB)

    Zhou Hongyu; Yan Yiming; Tang lin; Wen Chenlin; Zhang Shenji; Hua Ming; Han Chongzhan; Ding Xiaoji; Lan Liqiao; Fan Guoying; Yan Hua; Wang Xingfu; Wang Qi; Sun Suxu; Rong Yaning; Liu Shuzhen (Institute of Low Energy Nuclear Physics, Beijing Normal University, Beijing (CN))

    1989-05-01

    The cross sections of discrete gamma-ray produced by interactions of 14.9 MeV neutrons with carbon and niobium were investigated. A pulsed {ital T}({ital d},{ital n}){sup 4} He neutron source was used in the measurement. Neutron flux incident upon the sample was determined with the associated particle method. Technique of time-of-flight was used for reducing the background. A new method to calculate neutron flux attenuation in large cylindrical sample was proposed. The split of 4.439 MeV gamma-ray line from {sup 12}C({ital n},{ital n}{prime}{gamma}){sup 12}C reactions was confirmed. 79 discrete gamma-ray lines and their production cross sections for the interactions of 14.9 MeV neutrons with niobium were obtained for the first time.

  17. MODELING THE RADIATION SHIELDING OF BORON NEUTRON CAPTURE THERAPY BASED ON 2.4 MEV D-D NEUTRON GENERATOR FACILITY

    Directory of Open Access Journals (Sweden)

    Muhammad Mu’Alim

    2018-01-01

    PEMODELAN PERISAI RADIASI PADA FASILITAS BORON NEUTRON CAPTURE THERAPY BERBASIS GENERATOR NEUTRON D-D 2,4 MeV. Telah dimodelkan perisai radiasi pada fasilitas Boron Neutron Capture Therapy (BNCT berbasis reaksi D-D pada Neutron Generator 2,4 MeV dengan Beam Shaping Assembly (BSA yang telah didesain sebelumnya. Pemodelan ini dilakukan untuk memperoleh suatu desain perisai radiasi untuk fasilitas BNCT berbasis generator neutron 2,4 MeV. Pemodelan dilakukan dengan cara memvariasikan bahan dan ketebalan perisasi radiasi. Bahan yang dipilih adalah beton barit, parafin, polietilen terborasi dan timbal. Perhitungan dilakukan menggunakan program MCNPX dengan tally F4 untuk menentukan laju dosis yang keluar dari perisai radiasi. Desain periasi radiasi dinyatakan optimal jika radiasi yang dihasilkan diluar perisai radiasi tidak melebihi Nilai Batas Dosis (NBD yang telah ditentukan oleh BAPETEN. Hasilnya, diperoleh suatu desain perisai radiasi menggunakan lapisan utama beton barit setebal 100 cm yang mengelilingi ruangan 100 cm x 100 cm x 166,4 cm dan polietilen terborasi 40 cm yang mengelilingi bahan beton barit. Kemudian ditambahkan beton barit 10 cm dan polietilen terborasi 10 cm untuk mengurangi radiasi primer yang lurus dari BSA setelah keluar dari lapisan utama. Laju dosis terbesar adalah 4,58 μSv·jam-1 pada sel 227 dan laju dosis rata-rata yang dihasilkan adalah sebesar 0,65 µSv·jam-1. Nilai laju dosis tersebut masih dibawah ambang batas NBD yang diperbolehkan oleh BAPETEN untuk pekerja radiasi. Kata kunci: Perisai radiasi, tally, laju dosis radiasi, BSA, BNCT

  18. Study on the 21 MeV neutron flux characteristics obtained in the 3H(d,n)4He reaction using of gas target

    International Nuclear Information System (INIS)

    Lovchikova, G.N.; Polyakov, A.V.; Sal'nikov, O.A.; Simakov, S.P.; Sukhikh, S.Eh.; Trufanov, A.M.

    1983-01-01

    The possibility to use gas tritium target as neutron source with the energy 2 MeV for nuclear-physical studies has been considered. Characteristics of neutron flux crested in the reaction 3 H(d, n) 4 He to obtain neutrons are investigated. The study of inelastic scattering processes at the energies permits to expand the experiments conducted up to the present day on the study of spectra of inelastically scattered neutrons in a lower energy region and it is of interest for the clarification of appearance mechanism of high-energy neutrons in the spectra. Characteristics of neutron flux as a result of the reaction 3 (α, n) 4 He at the energy of falling deuterons Esub(d)=5.54 MeV are investigated. Measurements of spectra of scattered neutrons on carbon-12 at the angles 30, 45, 60, 90, 120, 150 degrees are made. Differential cross sections of elastic scattering are obtained

  19. Novel technologies and theoretical models in radiation therapy of cancer patients using 6.3 MeV fast neutrons produced by U-120 cyclotron

    Energy Technology Data Exchange (ETDEWEB)

    Musabaeva, L. I., E-mail: musabaevaLI@oncology.tomsk.ru; Lisin, V. A., E-mail: Lisin@oncology.tomsk.ru [Tomsk Cancer Research Institute, Kooperativny Street 5, Tomsk, 634050 (Russian Federation); Startseva, Zh. A., E-mail: zhanna.alex@rambler.ru; Gribova, O. V., E-mail: gribova79@mail.ru; Velikaya, V. V., E-mail: viktoria.v.v@inbox.ru [Tomsk Cancer Research Institute, Kooperativny Street 5, Tomsk, 634050 (Russian Federation); National Research Tomsk Polytechnic University, Lenin Avenue 30, Tomsk, 634050 (Russian Federation)

    2016-08-02

    The analysis of clinical use of neutron therapy with 6 MeV fast neutrons compared to conventional radiation therapy was carried out. The experience of using neutron and mixed neutron and photon therapy in patients with different radio-resistant malignant tumors shows the necessity of further studies and development of the novel approaches to densely-ionizing radiation. The results of dosimetry and radiobiological studies have been the basis for planning clinical programs for neutron therapy. Clinical trials over the past 30 years have shown that neutron therapy successfully destroys radio-resistant cancers, including salivary gland tumors, adenoidcystic carcinoma, inoperable sarcomas, locally advanced head and neck tumors, and locally advanced prostate cancer. Radiation therapy with 6.3 MeV fast neutrons used alone and in combination with photon therapy resulted in improved long-term treatment outcomes in patients with radio-resistant malignant tumors.

  20. Extension of the calibration of an NE-213 liquid scintillator based pulse height response spectrometer up to 18 MeV neutron energy and leakage spectrum measurements on bismuth at 8 MeV and 18 MeV neutron energies

    International Nuclear Information System (INIS)

    Fenyvesi, A.; Valastyan, I.; Olah, L.; Csikai, J.; Plompen, A.; Jaime, R.; Loevestam, G.; Semkova, V.

    2011-01-01

    Monoenergetic neutrons were produced at the Van de Graaff accelerator of the EC-JRC-Institute for Reference Materials and Measurements (IRMM, Geel, Belgium). An air-jet cooled D_2-gas target (1.2 bar, ΔE_d = 448 keV) was bombarded with E_d =4976 keV deuterons to produce neutrons up to E_n = 8 MeV energy via the D(d,n)"3He reaction. Higher energy neutrons up to E_n = 18 MeV were produced via the T(d,n)"4He reaction by bombarding a TiT target with E_d =1968 keV deuterons. Pulse height spectra were measured at different neutron energies from E_n = 8 MeV up to E_n = 18 MeV with the NE-213 liquid scintillator based Pulse Height Response Spectrometer (PHRS) of UD-IEP. The energy calibration of the PHRS system has been extended up to E_n = 18 MeV. Pulse height spectra induced by gamma photons have been simulated by the GRESP7 code. Neutron induced pulse height spectra have been simulated by the NRESP7 and MCNP-POLIMI codes. Comparison of the results of measurements and simulations enables the improvement of the parameter set of the function used by us to describe the light output dependence of the resolution of the PHRS system at light outputs of L > 2 light units. Also, it has been shown that the derivation method for unfolding neutron spectra from measured pulse height spectra performs well when relative measurements are done up to E_n = 18 MeV neutron energy. For matrix unfolding purposes, the NRESP7 code has to be preferred to calculate the pulse height response matrix of the PHRS system. Leakage spectra of neutrons behind bismuth slabs of different thicknesses have been measured with the PHRS system by using monoenergetic neutrons. The maximum slab thickness was d = 14 cm. Simulations of the measurements have been carried out with the MCNP-4c code. The necessary nuclear cross-sections were taken from the from the ENDF/B-VII and JEFF.3.1 data libraries. For both libraries, the agreement of measured and simulated neutron spectra is good for the 5 MeV ≤ En ≤ 18 MeV

  1. Construction of 144, 565 keV and 5.0 MeV monoenergetic neutron calibration fields at JAERI.

    Science.gov (United States)

    Tanimura, Y; Yoshizawa, M; Saegusa, J; Fujii, K; Shimizu, S; Yoshida, M; Shibata, Y; Uritani, A; Kudo, K

    2004-01-01

    Monoenergetic neutron calibration fields of 144, 565 keV and 5.0 MeV have been developed at the Facility of Radiation Standards of JAERI using a 4 MV Pelletron accelerator. The 7Li(p,n)7Be and 2H(d,n)3He reactions are employed for neutron production. The neutron energy was measured by the time-of-flight method with a liquid scintillation detector and calculated with the MCNP-ANT code. A long counter is employed as a neutron monitor because of the flat response. The monitor is set up where the influence of inscattered neutrons from devices and their supporting materials at a calibration point is as small as possible. The calibration coefficients from the monitor counts to the neutron fluence at a calibration point were obtained from the reference fluence measured with the transfer instrument of the primary standard laboratory (AIST), a 24.13 cm phi Bonner sphere counter. The traceability of the fields to AIST was established through the calibration.

  2. 238U neutron-induced fission cross section for incident neutron energies between 5 eV and 3.5 MeV

    International Nuclear Information System (INIS)

    Difilippo, F.C.; Perez, R.B.; de Saussure, G.; Olsen, D.K.; Ingle, R.W.

    1979-01-01

    A measurement of the 238 U neutron-induced fission cross section was performed at the ORELA Linac facility in the neutron energy range between 5 eV and 3.5 MeV. The favorable signal-to-background ratio and high resolution of this experiment resulted in the identificaion of 85 subthreshold fission resonances or clusters of resonances in the neutron energy region between 5 eV and 200 keV. The fission data below 100 keV are characteristic of a weak coupling situation between Class I and Class II levels. The structure of the fission levels at the 720 eV and 1210 eV fission clusters is discussed. There is an apparent enhancement of the fission cross section at the opening of the 2 + neutron inelastic channel in 238 U at 45 keV. An enhancement of the subthreshold fission cross section between 100 keV and 200 keV is tentatively interpreted in terms of the presence of a Class II, partially damped vibrational level. There is a marked structure in the fission cross section above 200 keV up to and including the plateau between 2 and 3.5 MeV. 11 figures and 6 tables

  3. Neutronics experiments for uncertainty assessment of tritium breeding in HCPB and HCLL blanket mock-ups irradiated with 14 MeV neutrons

    International Nuclear Information System (INIS)

    Batistoni, P.; Angelone, M.; Pillon, M.; Villari, R.; Fischer, U.; Klix, A.; Leichtle, D.; Kodeli, I.; Pohorecki, W.

    2012-01-01

    Two neutronics experiments have been carried out at 14 MeV neutron sources on mock-ups of the helium cooled pebble bed (HCBP) and the helium cooled lithium lead (HCLL) variants of ITER test blanket modules (TBMs). These experiments have provided an experimental validation of the calculations of the tritium production rate (TPR) in the two blanket concepts and an assessment of the uncertainties due to the uncertainties on nuclear data. This paper provides a brief summary of the HCPB experiment and then focuses in particular on the final results of the HCLL experiment. The TPR has been measured in the HCLL mock-up irradiated for long times at the Frascati 14 MeV Neutron Generator (FNG). Redundant and well-assessed experimental techniques have been used to measure the TPR by different teams for inter-comparison. Measurements of the neutron and gamma-ray spectra have also been performed. The analysis of the experiment, carried out by the MCNP code with FENDL-2.1 and JEFF-3.1.1 nuclear data libraries, and also including sensitivity/uncertainty analysis, shows good agreement between measurements and calculations, within the total uncertainty of 5.9% at 1σ level. (paper)

  4. Measurement of the neutron-induced fission cross section of 232Th relative to 235U from 0.7 to 30 MeV

    International Nuclear Information System (INIS)

    Behzens, T.W.; Ables, E.; Browne, T.C.

    1982-01-01

    The authors have measured the fission cross-section ratio 232 Th: 235 U as a function of neutron energy from 0.7 to 30 MeV using ionization fission chambers, the threshold cross-section method, and the time-of-flight technique at the Lawrence Livermore National Laboratory 100-MeV electron linear accelerator. The measured cross-section ratio, averaged over the neutron energy interval from 1.75 to 4.00 MeV, was 0.1086 + 0.0024

  5. Reduction in 14 MeV neutron generation rate by ICRF injection in D-3He burning plasmas

    International Nuclear Information System (INIS)

    Matsuura, Hideaki; Nakao, Yasuyuki

    2004-01-01

    The triton distribution function during ion cyclotron range of frequency (ICRF) waves injection in D- 3 He plasmas is examined by solving the 2-dimensional Fokker-Planck equation. Triton distribution function originally has a non-Maxwellian (tail) component around 1.01 MeV birth energy range due to D(d,p)T fusion reaction. Owing to the extension of the original tail by ICRF injection, the high-energy resonance tritons further increase, and the velocity-averaged T(d,n) 4 He fusion reaction rate coefficient, i.e. 14 MeV neutron generation rate, decreases from the values when triton is assumed to be Maxwellian. It is shown that when tritons absorb ∼1/200 of the fusion power from the waves in typical D- 3 He plasma, i.e. T=80 keV, n D =2x10 20 m -3 , τ E0 =3 sec and B=6T, the 14 MeV neutron generation rate is reduced by about ∼20% from the values for Maxwellian plasmas. (author)

  6. Comparisons of calculated and measured spectral distributions of neutrons from a 14-MeV neutron source inside the Tokamak Fusion Test Reactor

    International Nuclear Information System (INIS)

    Santoro, R.T.; Barnes, J.M.; Alsmiller, R.G. Jr.; Emmett, M.B.; Drischler, J.D.

    1985-12-01

    A recent paper presented neutron spectral distributions (energy greater than or equal to0.91 MeV) measured at various locations around the Tokamak Fusion Test Reactor (TFTR) at the Princeton Plasma Physics Laboratory. The neutron source for the series of measurements was a small D-T generator placed at various positions in the TFTR vacuum chamber. In the present paper the results of neutron transport calculations are presented and compared with these experimental data. The calculations were carried out using Monte Carlo methods and a very detailed model of the TFTR and the TFTR test cell. The calculated and experimental fluences per unit energy are compared in absolute units and are found to be in substantial agreement for five different combinations of source and detector positions

  7. Measurement of differential and double-differential neutron emission cross-sections for {sup 9}Be at 21.94 MeV neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Yaling [Lanzhou University, School of Nuclear Science and Technology, Lanzhou (China); Chinese Academy of Sciences, Institute of Modern Physics, Lanzhou (China); Ruan, Xichao; Huang, Hanxiong; Ren, Jie; Li, Xia; Nie, Yangbo [China Institute of Atomic Energy, Key Laboratory of Nuclear Data, Beijing (China); Li, Yongming [Chinese Academy of Engineering Physics, Mianyang, Sichuan (China); Zhou, Bin [Chinese Academy of Sciences, Institute of High Energy Physics, Beijing (China); Wei, Zheng; Yao, Zeen [Lanzhou University, School of Nuclear Science and Technology, Lanzhou (China); Engineering Research Center for Neutron Application, Ministry of Education, Lanzhou University, Lanzhou (China); Gao, Xiaofei; Yang, Lei [Chinese Academy of Sciences, Institute of Modern Physics, Lanzhou (China)

    2017-12-15

    The secondary neutron emission differential and double-differential cross sections (DX and DDXs) of n + {sup 9}Be have been measured at the neutron energy of 21.94 MeV using the multi-detector fast neutron time-of-flight (TOF) spectrometer. The data was derived by comparing the measured TOF spectra with detailed Monte Carlo simulation, and corrected with n-p scattering cross section. Meanwhile, theoretical calculations based on the Hauser-Feshbach and exciton model have been performed to compare with experimental data. Measured differential cross sections were also compared with other measurements. It was found that the experimental results were in agreement with other measurements and theoretical calculations, while discrepancies were also present in the whole energy region and at some angles. (orig.)

  8. Determination of Oxygen in Aluminum by Means of 14 MeV Neutrons with an Account of Flux Attenuation in the Sample

    Energy Technology Data Exchange (ETDEWEB)

    Brune, D; Jirlow, K

    1967-11-15

    This study concerns the determination of oxygen present at low levels in aluminum using the 14 MeV neutron activation technique. The sensitivity obtained amounted to 0.2 mg oxygen. Various nuclear methods for the oxygen determination have been briefly reviewed. The attenuation of fast neutrons inside the aluminum samples has been calculated.

  9. The 1H(t,n)3He reaction as monoenergetic neutron source in the (10/20) MeV energy interval

    International Nuclear Information System (INIS)

    Zago, G.

    1981-01-01

    The 1 H(t,n) 3 He reaction, considered as a neutron source in the (10/20) MeV energy interval, is a ''white'' neutron source having intensity, mean energy, and directionality which may prove advantageous in technological and biomedical researches. (author)

  10. /sup 1/H(t,n)/sup 3/He reaction as monoenergetic neutron source in the (10/20) MeV energy interval

    Energy Technology Data Exchange (ETDEWEB)

    Zago, G. (Padua Univ. (Italy). Ist. di Fisica)

    1981-11-14

    The /sup 1/H(t,n)/sup 3/He reaction, considered as a neutron source in the (10/20) MeV energy interval, is a ''white'' neutron source having intensity, mean energy, and directionality which may prove advantageous in technological and biomedical researches.

  11. Measurement of neutron activation cross-sections for elements Co, Ni, Y, Nb, Tm and Au between 12 and 20 MeV

    International Nuclear Information System (INIS)

    Iwasaki, S.; Matsuyama, S.; Ohkubo, T.; Fukuda, H.; Sakuma, M.; Kitamura, M.; Odano, N.

    1995-01-01

    Neutron activation cross-sections for cobalt, nickel, yttrium, niobium, thulium and gold have been measured in the neutron energies from 12 to 20 MeV with the reference cross section of NEA 93 Nb(n,2n) 92m Nb at Tohoku Dynamitron Facility. (author)

  12. Angular distribution and cross section measurements of 64Zn(n,α)61Ni reaction for neutron energy 5 MeV

    International Nuclear Information System (INIS)

    Chen Yingtang; Chen Zemin; Qi Huiquan; Li Mingtao

    1995-01-01

    A twin gridded ionization chamber with dual parameter data acquisition system is used to study neutron induced charged particle emission reaction. The angular distribution and cross section of α-particles from the 64 Zn(n,α) 61 Ni reaction are measured at neutron energy 5 MeV

  13. Calculations of nuclear data for the reactions of neutrons and protons with heavy nuclei at energy from 1 MeV up to 2 GeV

    International Nuclear Information System (INIS)

    Konshin, V.A.

    1995-01-01

    Several nuclear model codes were applied to calculations of nuclear data in the energy region from 1 MeV to 2 GeV. At energies from 1 to 20 MeV the statistical model code STAPRE was used for calculations of the neutron cross-sections for fission, (n,2n) and (n,3n) reaction cross-sections for 71 actinide isotopes. In the energy region from 10 to 100 MeV the nuclear theory code GNASH was used to calculate the neutron fission and (n,xn) cross-sections for 238 U, 235 U, 239 Pu, 232 Th, 237 Np, 238 Pu, 241 Am, 243 Am, 245 Cm and 246 Cm. At energies from 100 MeV to 2 GeV the intranuclear cascade-exciton model including the fission process was applied to calculations of the interactions of protons and neutrons with actinides and the calculated results are compared with experimental data. (author)

  14. Measurements and Monte Carlo calculations of neutron production cross-sections at 180o for the 140 MeV proton incident reactions on carbon, iron, and gold

    International Nuclear Information System (INIS)

    Iwamoto, Yosuke; Satoh, Daiki; Hagiwara, Masayuki; Yashima, Hiroshi; Nakane, Yoshihiro; Tamii, Atsushi; Iwase, Hiroshi; Endo, Akira; Nakashima, Hiroshi; Sakamoto, Yukio; Hatanaka, Kichiji; Niita, Koji

    2010-01-01

    The neutron production cross-sections of carbon, iron, and gold targets with 140 MeV protons at 180 o were measured at the RCNP cyclotron facility. The time-of-flight technique was used to obtain the neutron energy spectra in the energy range above 1 MeV. The carbon and iron target results were compared with the experimental data from 113 MeV (p,xn) reactions at 150 o reported by Meier et al. Our data agreed well with them in spite of different incident energies and angles. Calculations were then performed using different intra-nuclear cascade models (Bertini, ISOBAR, and JQMD) implemented with PHITS code. The results calculated using the ISOBAR and JQMD models roughly agreed with the experimental iron and gold target data, but the Bertini could not reproduce the high-energy neutrons above 10 MeV.

  15. Identification and spectrometry of charged particles produced in reactions induced by 14 MeV neutrons. II

    International Nuclear Information System (INIS)

    Sellem, C.; Perroud, J.P.; Loude, J.F.

    1975-01-01

    A counter telescope consisting of gas proportional counters, a thin semiconductor detector and a thick one has been built and used for the study of the angular differential cross sections of (n, charged particles) reactions induced by 14 MeV neutrons. Detection of the α-particles emitted in the neutron production reaction 3 H(d,n) 4 He gives a time reference for the measurement of the time of flight of the charged particles and allows a precise monitoring of the intensity of the neutron beam. High energy protons, deuterons and tritons are identified by their energy losses in the thin semiconductor detector and in the thick one and by their time of flight. Low energy protons, deuterons, tritons and all α-particles stop in the thin semiconductor detector and are identified by their energy losses in this detector and in one gas proportional counter as well as by their time of flight. It is possible to identify and to measure the energy of all charged particles in the energy range of 2 to 15 MeV: a very low background results from the use of the time of flight. (Auth.)

  16. Measurement of the neutron-induced deuteron breakup reaction cross-section between 5 and 25 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Laborie, J.M.; Ledoux, X.; Varignon, C.; Lazauskas, R.; Morillon, B.; Belier, G. [CEA, DAM, DIF, Arpajon (France)

    2012-06-15

    This article presents a full program devoted to the calculation and the measurement of the neutron-induced deuteron break-up reaction cross-section between 5 and 10 MeV, and between 20 and 25 MeV. Measurements are compared with theoretical calculations based on the solution of the Faddeev equations for a realistic nuclear Hamiltonian. The experiments were performed at the Tandem 7 MV accelerator at CEA, DAM, DIF, France. The measurements were carried out with a C{sub 6}D{sub 6} detector as active deuterium target located at the center of a 4{pi} neutron counter (see C. Varignon et al., Nucl. Instrum. Methods B 248, 329 (2006)) which allows to count the two neutrons emitted in the {sup 2}H(n, 2n)p reaction. Comparisons of the new data and calculations are made with the existing data as well as the CENDL2, JENDL3.3 and ENDF/B-VII evaluations. (orig.)

  17. Contribution to the study of 14 MeV neutron scattering by {sup 12}C using a time-of-flight spectrometer (1963); Contribution a l'etude de la diffusion des neutrons de 14 MeV par {sup 12}C, a l'aide d'un spectrometre a temps de vol (1963)

    Energy Technology Data Exchange (ETDEWEB)

    Perrin, P [Commisariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1963-07-15

    Experimental measurements of 14 MeV fast neutrons scattering by {sup 12}C by time-flight spectrometer, with a 1.7 n. sec over-all resolution. The excitation of the 7.65 MeV level is observed. (author) [French] Etude experimentate de la diffusion par {sup 12}C des neutrons rapides de 14 MeV a l'aide d'un spectrometre de resolution totale de 17 n/s. Observation de l'excitation du niveau 0+ de 7,65 MeV. (auteur)

  18. Phase-shift-analysis approach to elastic neutron scattering from /sup 12/C between 9 and 12 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Tornow, W. (Tuebingen Univ. (Germany, F.R.). Physikalisches Inst.); Walter, R.L.; Byrd, R.C. (Duke Univ., Durham, NC (USA). Dept. of Physics; Triangle Universities Nuclear Lab., Durham, NC (USA))

    1985-03-01

    The excitation energy, spin and parity of levels in /sup 13/C have been determined for excitation energies between 13 and 16 MeV via a phase-shift analysis of the measured total cross section, elastic differential cross section and analysing power for n + /sup 12/C in the neutron energy range from 8.9 to 12.0 MeV. New analysing power measurements are reported for this energy range. The present and previous experimental data are well described by the phase shifts obtained. The non-elastic cross section for n + /sup 12/C predicted from the phase shifts is in good agreement with the ENDF/B-V evaluation. The need for further experimental data is pointed out.

  19. Phase-shift-analysis approach to elastic neutron scattering from 12C between 9 and 12 MeV

    International Nuclear Information System (INIS)

    Tornow, W.

    1985-01-01

    The excitation energy, spin and parity of levels in 13 C have been determined for excitation energies between 13 and 16 MeV via a phase-shift analysis of the measured total cross section, elastic differential cross section and analysing power for n + 12 C in the neutron energy range from 8.9 to 12.0 MeV. New analysing power measurements are reported for this energy range. The present and previous experimental data are well described by the phase shifts obtained. The non-elastic cross section for n + 12 C predicted from the phase shifts is in good agreement with the ENDF/B-V evaluation. The need for further experimental data is pointed out. (author)

  20. Fission Product Yields from {sup 232}Th, {sup 238}U, and {sup 235}U Using 14 MeV Neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Pierson, B.D., E-mail: bpnuke@umich.edu [Department of Nuclear Engineering Radiological Sciences, University of Michigan, 2355 Bonisteel Blvd., Ann Arbor, MI 48109 (United States); Pacific Northwest National Laboratory, P.O. Box 999, Richland, WA 99352 (United States); Greenwood, L.R. [Pacific Northwest National Laboratory, P.O. Box 999, Richland, WA 99352 (United States); Flaska, M. [Department of Mechanical and Nuclear Engineering, Pennsylvania State University, 227 Reber Bldg., University Park, PA 16802 (United States); Pozzi, S.A. [Department of Nuclear Engineering Radiological Sciences, University of Michigan, 2355 Bonisteel Blvd., Ann Arbor, MI 48109 (United States)

    2017-01-15

    Neutron-induced fission yield studies using deuterium-tritium fusion-produced 14 MeV neutrons have not yet directly measured fission yields from fission products with half-lives on the order of seconds (far from the line of nuclear stability). Fundamental data of this nature are important for improving and validating the current models of the nuclear fission process. Cyclic neutron activation analysis (CNAA) was performed on three actinide targets–thorium-oxide, depleted uranium metal, and highly enriched uranium metal–at the University of Michigan's Neutron Science Laboratory (UM-NSL) using a pneumatic system and Thermo-Scientific D711 accelerator-based fusion neutron generator. This was done to measure the fission yields of short-lived fission products and to examine the differences between the delayed fission product signatures of the three actinides. The measured data were compared against previously published results for {sup 89}Kr, −90, and −92 and {sup 138}Xe, −139, and −140. The average percent deviation of the measured values from the Evaluated Nuclear Data Files VII.1 (ENDF/B-VII.1) for thorium, depleted-uranium, and highly-enriched uranium were −10.2%, 4.5%, and −12.9%, respectively. In addition to the measurements of the six known fission products, 23 new fission yield measurements from {sup 84}As to {sup 146}La are presented.

  1. Neutron capture cross-section measurements for 238U between 0.4 and 1.4 MeV

    Science.gov (United States)

    Krishichayan, Fnu; Finch, S. W.; Howell, C. R.; Tonchev, A. P.; Tornow, W.

    2017-09-01

    Neutron-induced radiative-capture cross-section data of 238U are crucial for fundamental nuclear physics as well as for Stewardship Science, for advanced-fuel-cycle calculations, and for nuclear astrophysics. Based on different techniques, there are a large number of 238U(n, γ) 239U cross-section data available in the literature. However, there is a lack of systematic and consistent measurements in the 0.1 to 3.0 MeV energy range. The goal of the neutron-capture project at TUNL is to provide accurate 238U(n, γ) 239U cross-section data in this energy range. The 238U samples, sandwiched between gold foils of the same size, were irradiated for 8-14 hours with monoenergetic neutrons. To avoid any contribution from thermal neutrons, the 238U and 197Au targets were placed inside of a thin-walled pill-box made of 238U. Finally, the whole pill-box was wrapped in a gold foil as well. After irradiation, the samples were gamma-counted at the TUNL's low-background counting facility using high-efficient HPGe detectors. The 197Au monitor foils were used to calculate the neutron flux. The experimental technique and 238U(n, γ) 239U cross-section results at 6 energies will be discussed during the meeting.

  2. Neutron-proton analyzing power at 12 MeV and charged πNN coupling constant

    International Nuclear Information System (INIS)

    Braun, R.T.; Tornow, W.; Gonzalez Trotter, D.E.; Howell, C.R.; Machleidt, R.; Roper, C.D.; Salinas, F.; Setze, H.R.; Walter, R.L.

    1995-01-01

    Recent reanalysis of scattering data by the Nijmegen group has led to new values for the πNN coupling constants, g 2 πdegree /4π and g 2 π± /4π, about 6% smaller than the previously accepted values. The impact of this finding is far reaching. Since the neutron-proton A y (θ) is dominated at low energies by the one-pion-exchange mechanism, accurate np data should provide unique information as to the magnitude of g 2 π± /4π. Using a new experimental setup consisting of a shielded neutron source, a five-pair neutron detector array, a n- 4 He polarimeter, and an intense polarized source with fast spin-flipping capability, we have measured a 15 point angular distribution of the neutron-proton A y (θ) at and incident neutron energy of 12 MeV to a statistical accuracy of 5x10 -4 . We will discuss the data taking procedures, the analysis, and the corrections applied to the data. Preliminary results will be presented

  3. Fast neutron (14 MeV) attenuation analysis in saturated core samples and its application in well logging

    International Nuclear Information System (INIS)

    Amin Attarzadeh; Mohammad Kamal Ghassem Al Askari; Tagy Bayat

    2009-01-01

    To introduce the application of nuclear logging, it is appropriate to provide a motivation for the use of nuclear measurement techniques in well logging. Importance aspects of the geological sciences are for instance grain and porosity structure and porosity volume of the rocks, as well as the transport properties of a fluid in the porous media. Nuclear measurements are, as a rule non-intrusive. Namely, a measurement does not destroy the sample, and it does not interfere with the process to be measured. Also, non- intrusive measurements are often much faster than the radiation methods, and can also be applied in field measurements. A common type of nuclear measurement employs neutron irradiation. It is powerful technique for geophysical analysis. In this research we illustrate the detail of this technique and it's applications to well logging and oil industry. Experiments have been performed to investigate the possibilities of using neutron attenuation measurements to determine water and oil content of rock sample. A beam of 14 MeV neutrons produced by a 150 KV neutron generator was attenuated by different samples and subsequently detected with plastic scintillators NE102 (Fast counter). Each sample was saturated with water and oil. The difference in neutron attenuation between dry and wet samples was compared with the fluid content determined by mass balance of the sample. In this experiment we were able to determine 3% of humidity in standard sample model (SiO 2 ) and estimate porosity in geological samples when saturated with different fluids. (Author)

  4. Calculations of the relative effectiveness of alanine for neutrons with energies up to 17.1 MeV

    International Nuclear Information System (INIS)

    Gerstenberg, H.M.; Coyne, J.J.

    1990-01-01

    The relative effectiveness (RE) of alanine has been calculated for neutrons using the RE of alanine for charged particles. The neutrons interact with one or more of the elements (hydrogen, carbon, nitrogen and oxygen) that compose the alanine. These interactions produce spectra of secondary charged particles consisting of ions of H, D, He, Be, B, C, N and O. From a combination of the calculated secondary charged particle spectra generated by the slowing down neutrons, and the calculated RE of the ions produced, a RE for the neutrons can be obtained. In addition, lineal energy spectra were determined for neutrons with energies up to 17.1 MeV interacting with alanine. An analytical code was used to calculate these spectra for a 1 μm diameter alanine cell surrounded by an alanine medium. For comparison, similar calculations were made for muscle tissue. Finally, the calculated differential RE was folded with dose distributions to obtain RE-weighted distributions for alanine. (author)

  5. Fission cross section and fission fragment angular distribution for oriented nucleus fission by intermediate energy neutrons (epsilon < or approximately 1 Mev)

    International Nuclear Information System (INIS)

    Barabanov, A.L.; Grechukhin, D.P.

    1985-01-01

    General analysis is conducted, and formulae for fission cross section and angular distribution of fission fragments of oriented nuclei by fast neutrons are presented. Geometrical coefficients making up the formulae permitting to carry out calculations for target nuclei with spins I=3/2, 5/2, 7/2 at interaction energies epsilon < or approximately 1 MeV are tabulated. Results of demonstrative calculation of fission fragment angular distribution of oriented sup(235)U nuclei by 0.1 <= epsilon <= 1.0 MeV neutrons reveal that angular distribution weakly depends on the set of permeability factors of neutron waves applied in the calculations

  6. Measurements of the {sup 235}U(n,f) cross section in the 3 to 30 MeV neutron energy region

    Energy Technology Data Exchange (ETDEWEB)

    Carlson, A.D.; Wasson, O.A. [National Institute of Standards and Technology, Gaithersburg, MD (United States); Lisowski, P.W. [Los Alamos National Lab., NM (United States)] [and others

    1991-12-31

    To improve the accuracy of the {sup 235}U(n,f) cross section, measurements have been made of this standard cross section at the target 4 facility at Los Alamos National Laboratory (LANL). The data were obtained at the 20-meter flight path of that facility. The fission reaction rate was determined with a fast parallel plate ionization chamber and the neutron fluence was measured with an annular proton recoil telescope. The measurements provide the shape of the {sup 235}U(n,f) cross section relative to the hydrogen scattering cross section for neutron energies from about 3 to 30 MeV neutron energy. The data have been normalized to the very accurately known value near 14 MeV. The results are in good agreement with the ENDF/B-VI evaluation up to about 15 MeV neutron energy. Above this energy differences as large as 5% are observed.

  7. Measurement of neutron detection efficiency between 22 and 174 MeV using two different kinds of Pb-scintillating fiber sampling calorimeters

    Energy Technology Data Exchange (ETDEWEB)

    Anelli, M.; Bertolucci, S. [Laboratori Nazionali di Frascati, INFN (Italy); Bini, C. [Dipartimento di Fisica dell' Universita ' La Sapienza' , Roma (Italy); INFN Sezione di Roma, Roma (Italy); Branchini, P. [INFN Sezione di Roma Tre, Roma (Italy); Corradi, G.; Curceanu, C. [Laboratori Nazionali di Frascati, INFN (Italy); De Zorzi, G.; Di Domenico, A. [Dipartimento di Fisica dell' Universita ' La Sapienza' , Roma (Italy); INFN Sezione di Roma, Roma (Italy); Di Micco, B. [Dipartimento di Fisica dell' Universita ' Roma Tre' , Roma (Italy); INFN Sezione di Roma Tre, Roma (Italy); Ferrari, A. [Fondazione CNAO, Milano (Italy); Fiore, S.; Gauzzi, P. [Dipartimento di Fisica dell' Universita ' La Sapienza' , Roma (Italy); INFN Sezione di Roma, Roma (Italy); Giovannella, S.; Happacher, F. [Laboratori Nazionali di Frascati, INFN (Italy); Iliescu, M. [Laboratori Nazionali di Frascati, INFN (Italy); IFIN-HH, Bucharest (Romania); Luca, A.; Martini, M. [Laboratori Nazionali di Frascati, INFN (Italy); Miscetti, S., E-mail: stefano.miscetti@lnf.infn.i [Laboratori Nazionali di Frascati, INFN (Italy); Nguyen, F. [Dipartimento di Fisica dell' Universita ' Roma Tre' , Roma (Italy); INFN Sezione di Roma Tre, Roma (Italy); Passeri, A. [INFN Sezione di Roma Tre, Roma (Italy)

    2010-05-21

    We exposed a prototype of the lead-scintillating fiber KLOE calorimeter to neutron beam of 21, 46 and 174 MeV at The Svedberg Laboratory, Uppsala, to study its neutron detection efficiency. This has been found larger than what expected considering the scintillator thickness of the prototype. We show preliminary measurement carried out with a different prototype with a larger lead/fiber ratio, which proves the relevance of passive material to neutron detection efficiency in this kind of calorimeters.

  8. Amount of sister chromatid exchanges and survival of Chinese hamster V79-4 cells after irradiation with 0,7 MeV neutrons

    International Nuclear Information System (INIS)

    Lapidus, I.L.; Nasonova, E.A.

    1987-01-01

    The dependence of the survival and induction of sister chromatid exchanges (SCEs) in Chinese hamster V79-4 cells on the dose of γ-rays and neutrons with average energy 0.7 MeV has been analysed. The value of RBE for neutrons was 5.5. It has been shown that the number of SCE increased with the dose of γ-irradiation and no induction could be detected after neutron irradiation

  9. Responses of conventional and extended-range neutron detectors in mixed radiation fields around a 150-MeV electron LINAC

    International Nuclear Information System (INIS)

    Lin, Yu-Chi; Sheu, Rong-Jiun; Chen, Ang-Yu

    2015-01-01

    This study analyzed the responses of two types of neutron detector in mixed gamma-ray and neutron radiation fields around a 150-MeV electron linear accelerator (LINAC). The detectors were self-assembled, high efficiency, and designed in two configurations: (1) a conventional moderated-type neutron detector based on a large cylindrical He-3 proportional counter; and (2) an extended-range version with an embedded layer of lead in the moderator to increase the detector’s sensitivity to high-energy neutrons. Two sets of the detectors were used to measure neutrons at the downstream and lateral locations simultaneously, where the radiation fields differed considerably in intensities and spectra of gamma rays and neutrons. Analyzing the detector responses through a comparison between calculations and measurements indicated that not only neutrons but also high-energy gamma rays (>5 MeV) triggered the detectors because of photoneutrons produced in the detector materials. In the lateral direction, the contribution of photoneutrons to both detectors was negligible. Downstream of the LINAC, where high-energy photons were abundant, photoneutrons contributed approximately 6% of the response of the conventional neutron detector; however, almost 50% of the registered counts of the extended-range neutron detector were from photoneutrons because of the presence of the detector rather than the effect of the neutron field. Dose readings delivered by extended-range neutron detectors should be interpreted cautiously when used in radiation fields containing a mixture of neutrons and high-energy gamma rays

  10. Cross Sections for High-Energy Gamma Transitions from MeV Neutron Capture in {sup 206}Pb

    Energy Technology Data Exchange (ETDEWEB)

    Bergqvist, I; Lundberg, B; Nilsson, L

    1970-03-15

    Gamma-ray spectra from neutron capture in Pb (radiogenic lead) in the energy range 1.5 to 8.5 MeV were recorded using time-of-flight techniques. The spectrometer was a Nal (Tl) crystal, 20.8 cm long and 22.6 cm in diameter. The spectra are dominated by gamma transitions to levels with large single-particle strength, in agreement with predictions of semi-direct capture theories. The theories predict enhancements of the direct capture cross section by a factor of 10 - 15 in the region of the giant dipole resonance. The observed enhancement is about 50.

  11. Evaluation of n+Mn-55 cross section data up to 150 MeV neutron energy

    International Nuclear Information System (INIS)

    Pereslavtsev, P.; Fischer, U.

    2008-01-01

    A new evaluation was performed for the reaction system n + 55 Mn in the neutron energy range from 0.001 to 150 MeV. The evaluation is based on the use of the ECIS96 and GNASH codes. A good description of available experimental data was achieved. A very limited set of existing evaluated data from the available international nuclear data libraries was used for the evaluation. The final general purpose data file was prepared in standard ENDF-6 format and was verified with standard format checking utilities. The data file will undergo benchmark testing and will be finally integrated into the JEFF-3.2 data library. (authors)

  12. Spallation Neutron Emission Spectra in Some Amphoter Target Nuclei by Proton Beam Up to 140 MeV Energy

    International Nuclear Information System (INIS)

    Yildirim, G.

    2008-01-01

    In the present study, the (p,xn) reaction neutron-emission spectra for some amphoter target nuclei as 27 A l, 64 Z n, 120 S n, and 208 P b were investigated up to 140 MeV incident proton energy. The pre-equilibrium calculations were calculated by using the hybrid model, the geometry dependent hybrid model, the full exciton model and the cascade exciton model. The reaction equilibrium component was calculated with a traditional compound nucleus model developed by Weisskopf Ewing. Calculation results have been discussed and compared with the available experimental data in literature

  13. Neutron-proton analyzing power data at 7. 6, 12. 0, 14. 1, 16. 0, 18. 5 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Weisel, G.J.; Tornow, W.; Howell, C.R.; Felsher, P.D.; Alohali, M.; Chen, Z.P.; Walter, R.L. (Duke Univ., Durham, NC (US) Triangle Universities Nuclear Lab., Durham, NC (US)); Lambert, J.M.; Treado, P.A. (Georgetown Univ., Washington, DC, (US))

    1990-11-15

    Neutron-Proton A{sub y} ({theta}) measurements have been made at 7.6, 12.0, 14.1, 16.0, and 18.5 MeV. A sensitivity study establishes the importance of A{sub y} ({theta}) in determining the {sup 3}P{sub 0,1,2} phase shifts in n-p scattering. The data are compared to the predictions of two phase-shift studies (one of which incorporates CIB effects), and the Paris and Bonn NN potentials.

  14. A new empirical formula for 14-15 MeV neutron-induced (n, p) reaction cross sections

    International Nuclear Information System (INIS)

    Tel, E; Sarer, B; Okuducu, S; Aydin, A; Tanir, G

    2003-01-01

    In this study, we have suggested a new empirical formula to reproduce the cross sections of the (n, p) reactions at 14-15 MeV for the neutron incident energy. This formula obtained using the asymmetry parameters represents a modification to the original formula of Levkovskii. The resulting modified formulae yielded cross sections, representing smaller χ 2 deviations from experimental values, and values much closer to unity as compared with those calculated using Levkovskii's original formula. The results obtained have been discussed and compared with the existing formulae, and found to be well in agreement, when used to correlate the available experimental σ(n, p) data of different nuclei

  15. Evaluation of neutron and proton nuclear data of {sup 28}Si for energies up to 200 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Weili [Kyushu Univ., Department of Applied Quantum Physics and Nuclear Engineering, Fukuoka (Japan); Watanabe, Y. [Kyushu Univ., Department of Advanced Energy Engineering Science, Fukuoka (Japan); Sukhovitskii, E. Sh. [Radiation Physics and Chemistry Problems Institute, Minsk-Sosny (Belarus); Iwamoto, O.; Chiba, S. [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    2001-03-01

    The neutron and proton nuclear data of {sup 28}Si up to 200 MeV are evaluated for various nuclear engineering applications. The soft rotator model and the coupled-channel method are used to perform a consistent analysis of the collective band structure of {sup 28}Si and nucleon scattering from {sup 28}Si. The GNASH nuclear model code is used for compound and preequilibrium particle emission calculations, where the emission of {sup 3}He is also included. Comparisons show overall good agreement with various experimental data. (author)

  16. Dual sightline measurements of MeV range deuterons with neutron and gamma-ray spectroscopy at JET

    DEFF Research Database (Denmark)

    Eriksson, J.; Nocente, M.; Binda, F.

    2015-01-01

    Observations made in a JET experiment aimed at accelerating deuterons to the MeV range by third harmonic radio-frequency (RF) heating coupled into a deuterium beam are reported. Measurements are based on a set of advanced neutron and gamma-ray spectrometers that, for the first time, observe......-ray spectroscopy based on a one-dimensional model and by a consistency check among the individual measurement techniques. A systematic difference is seen between the two lines of sight and is interpreted to originate from the sensitivity of the oblique detectors to the pitch-angle structure of the distribution...

  17. Evaluation of neutron and proton nuclear data of 28Si for energies up to 200 MeV

    International Nuclear Information System (INIS)

    Sun, Weili; Watanabe, Y.; Sukhovitskii, E. Sh.; Iwamoto, O.; Chiba, S.

    2001-01-01

    The neutron and proton nuclear data of 28 Si up to 200 MeV are evaluated for various nuclear engineering applications. The soft rotator model and the coupled-channel method are used to perform a consistent analysis of the collective band structure of 28 Si and nucleon scattering from 28 Si. The GNASH nuclear model code is used for compound and preequilibrium particle emission calculations, where the emission of 3 He is also included. Comparisons show overall good agreement with various experimental data. (author)

  18. The prediction of Neutron Elastic Scattering from Tritium for E(n) = 6-14 MeV

    International Nuclear Information System (INIS)

    Anderson, J.D.; Dietrich, F.S.; Luu, T.; McNabb, D.P.; Navratil, P.; Quaglioni, S.

    2010-01-01

    In a recent report Navratil et al. evaluated the angle-integrated cross section and the angular distribution for 14-MeV n+T elastic scattering by inferring these cross sections from accurately measured p+3He angular distributions. This evaluation used a combination of two theoretical treatments, based on the no-core shell model and resonating-group method (NCSM/RGM) and on the R-matrix formalism, to connect the two charge-symmetric reactions n+T and p+ 3 He. In this report we extend this treatment to cover the neutron incident energy range 6-14 MeV. To do this, we evaluate angle-dependent correction factors for the NCSM/RGM calculations so that they agree with the p+ 3 He data near 6 MeV, and using the results found earlier near 14 MeV we interpolate these correction factors to obtain correction factors throughout the 6-14 MeV energy range. The agreement between the corrected NCSM/RGM and R-Matrix values for the integral elastic cross sections is excellent (±1%), and these are in very good agreement with total cross section experiments. This result can be attributed to the nearly constant correction factors at forward angles, and to the evidently satisfactory physics content of the two calculations. The difference in angular shape, obtained by comparing values of the scattering probability distribution P(μ) vs. μ(the cosine of the c.m. scattering angle), is about ±4% and appears to be related to differences in the two theoretical calculations. Averaging the calculations yields P(μ) values with errors of ±2 1/2 % or less. These averaged values, along with the corresponding quantities for the differential cross sections, will form the basis of a new evaluation of n+T elastic scattering. Computer files of the results discussed in this report will be supplied upon request.

  19. The prediction of Neutron Elastic Scattering from Tritium for E(n) = 6-14 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, J D; Dietrich, F S; Luu, T; McNabb, D P; Navratil, P; Quaglioni, S

    2010-06-14

    In a recent report Navratil et al. evaluated the angle-integrated cross section and the angular distribution for 14-MeV n+T elastic scattering by inferring these cross sections from accurately measured p+3He angular distributions. This evaluation used a combination of two theoretical treatments, based on the no-core shell model and resonating-group method (NCSM/RGM) and on the R-matrix formalism, to connect the two charge-symmetric reactions n+T and p+{sup 3}He. In this report we extend this treatment to cover the neutron incident energy range 6-14 MeV. To do this, we evaluate angle-dependent correction factors for the NCSM/RGM calculations so that they agree with the p+{sup 3}He data near 6 MeV, and using the results found earlier near 14 MeV we interpolate these correction factors to obtain correction factors throughout the 6-14 MeV energy range. The agreement between the corrected NCSM/RGM and R-Matrix values for the integral elastic cross sections is excellent ({+-}1%), and these are in very good agreement with total cross section experiments. This result can be attributed to the nearly constant correction factors at forward angles, and to the evidently satisfactory physics content of the two calculations. The difference in angular shape, obtained by comparing values of the scattering probability distribution P({mu}) vs. {mu}(the cosine of the c.m. scattering angle), is about {+-}4% and appears to be related to differences in the two theoretical calculations. Averaging the calculations yields P({mu}) values with errors of {+-}2 1/2 % or less. These averaged values, along with the corresponding quantities for the differential cross sections, will form the basis of a new evaluation of n+T elastic scattering. Computer files of the results discussed in this report will be supplied upon request.

  20. Measurements of fission product yield in the neutron-induced fission of {sup 238}U with average energies of 9.35 MeV and 12.52 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Mukerji, Sadhana; Krishnani, Pritam Das; Suryanarayana, Saraswatula Venkat; Naik, Haladhara; Goswami, Ashok [Bhabha Atomic Research Centre, Mumbai (India); Shivashankar, Byrapura Siddaramaiah [Manipal University, Manipal (India); Mulik, Vikas Kaluram [University of Pune, Pune (India)

    2014-07-15

    The yields of various fission products in the neutron-induced fission of {sup 238}U with the flux-weighted averaged neutron energies of 9.35 MeV and 12.52 MeV were determined by using an off-line gamma ray spectroscopic technique. The neutrons were generated using the {sup 7}Li(p, n) reaction at Bhabha Atomic Research Centre-Tata Institute of Fundamental Research Pelletron facility, Mumbai. The gamma- ray activities of the fission products were counted in a highly-shielded HPGe detector over a period of several weeks to identify the decaying fission products. At both the neutron energies, the fission-yield values are reported for twelve fission product. The results obtained from the present work have been compared with the similar data for mono-energetic neutrons of comparable energy from the literature and are found to be in good agreement. The peak-to-valley (P/V) ratios were calculated from the fission-yield data and were found to decreases for neutron energy from 9.35 to 12.52 MeV, which indicates the role of excitation energy. The effect of the nuclear structure on the fission product-yield is discussed.

  1. Measurements of fission product yield in the neutron-induced fission of 238U with average energies of 9.35 MeV and 12.52 MeV

    Science.gov (United States)

    Mukerji, Sadhana; Krishnani, Pritam Das; Shivashankar, Byrapura Siddaramaiah; Mulik, Vikas Kaluram; Suryanarayana, Saraswatula Venkat; Naik, Haladhara; Goswami, Ashok

    2014-07-01

    The yields of various fission products in the neutron-induced fission of 238U with the flux-weightedaveraged neutron energies of 9.35 MeV and 12.52 MeV were determined by using an off-line gammaray spectroscopic technique. The neutrons were generated using the 7Li(p, n) reaction at Bhabha Atomic Research Centre-Tata Institute of Fundamental Research Pelletron facility, Mumbai. The gamma- ray activities of the fission products were counted in a highly-shielded HPGe detector over a period of several weeks to identify the decaying fission products. At both the neutron energies, the fission-yield values are reported for twelve fission product. The results obtained from the present work have been compared with the similar data for mono-energetic neutrons of comparable energy from the literature and are found to be in good agreement. The peak-to-valley (P/V) ratios were calculated from the fission-yield data and were found to decreases for neutron energy from 9.35 to 12.52 MeV, which indicates the role of excitation energy. The effect of the nuclear structure on the fission product-yield is discussed.

  2. Determination of average fission fraction produced by 14 MeV neutrons in assemblies with large volume of depleted uranium

    International Nuclear Information System (INIS)

    Wang Dalun; Li Benci; Wang Xiuchun; Li Yijun; Zhang Shaohua; He Yongwu

    1991-07-01

    The average fission fraction of 238 U caused by 14 MeV neutrons in assemblies with large volume depleted uranium has been determined. The measured value of p f 238U (R ∞ depleted ) 14 was 0.897 ± 0.036. Measurements were also completed for neutron flux distribution and average fission fraction of 235 U isotope in depleted uranium sphere. Values of p f 238U (R depleted ) have been obtained by using a series of uranium spheres. For a sphere with Φ 600 the p f 23 '8 U (R 300 depleted ) is 0.823 ± 0.041, the density of depleted uranium assembly is 18.8g/cm 3 and total weight of assembly is about 2.8t

  3. Neutron-proton analyzing power data between 7.6 and 18.5 MeV

    International Nuclear Information System (INIS)

    Weisel, G.J.; Tornow, W.; Howell, C.R.; Felsher, P.D.; AlOhali, M.; Chen, Z.P.; Walter, R.L.; Lambert, J.M.; Treado, P.A.; Slaus, I.

    1992-01-01

    Measurements of the analyzing power A y (θ) for neutron-proton scattering have been performed at 7.6, 12.0, 14.1, 16.0, and 18.5 MeV. The experimental setup is described as are the finite-geometry corrections applied to the data. One of these corrections, due to the presence of carbon in the scintillators used for neutron detection, is discussed in detail. The A y (θ) data are compared to the predictions of the Paris and Bonn nucleon-nucleon potentials and the predictions of two phase-shift analyses, one of which incorporates charge-independence breaking effects in the 3 P waves

  4. Sister chromatid exchanges induced in CHO cells by X-rays or 5.5 MeV neutrons

    International Nuclear Information System (INIS)

    Bocian, E.; Rosiek, O.; Sablinski, J.; Ziemba-Zoltowska, B.

    1986-01-01

    The induction of sister chromatid exchanges (SCEs) by X-rays (1-9 Gy) and 5.5 MeV neutrons (0.5-4 Gy) was studied in CHO cells. A dose-dependent increase of the frequency of SCE was found for both radiations when cells with BrdUrd substituted DNA were irradiated. The similar doubling dose, approx. 4 Gy, was found for X-rays and neutrons. The increase of the SCE frequency was not clearly dependent on the dose when cells with BrdUrd unsubstituted DNA were irradiated. In this case a dose of 4 Gy enhanced the SCE frequency only by the factor of 1.3. (author)

  5. Study of the production of uranium-233 in natural thorium subjected to a neutron flux of 14 MeV

    International Nuclear Information System (INIS)

    Abel, G.; Martel, J.G.; St Germain, J.P.

    1979-01-01

    This is a study of neutron flux and reactivity in several simplified models of a fusion reactor blanket composed of thorium, carbon and a stainless steel structure. The objective is the comparative determination, theoretical and experimental, of values for the conversion of nuclei of Th-232 into fissile U-233 nuclei in such a blanket. Theoretical calculations are carried out using the ANISN (transport equation) and MORSE (Monte Carlo) codes. Experimental values are measured in a stainless steel rack structure allowing simplified blanket models to be mounted around a 14 MeV neutron source. In the first year of work theoretical flux values have been obtained, the necesssary detectors constructed, the rack structure set up, programs worked out for the reactivity calculations, and finally verification methods worked out in conditions similar to those that will prevail. (LL) [fr

  6. Monte Carlo calculation of the cross-section of single event upset induced by 14MeV neutrons

    International Nuclear Information System (INIS)

    Li, H.; Deng, J.Y.; Chang, D.M.

    2005-01-01

    High-density static random access memory may experience single event upsets (SEU) in neutron environments. We present a new method to calculate the SEU cross-section. Our method is based on explicit generation and transport of the secondary reaction products and detailed accounting for energy loss by ionization. Instead of simulating the behavior of the circuit, we use the Monte Carlo method to simulate the process of energy deposition in sensitive volumes. Thus, we do not need to know details about the circuit. We only need a reasonable guess for the size of the sensitive volumes. In the Monte Carlo simulation, the cross-section of SEU induced by 14MeV neutrons is calculated. We can see that the Monte Carlo simulation not only can provide a new method to calculate SEU cross-section, but also can give a detailed description about random process of the SEU

  7. 99mTc by 99Mo produced at the ENEA-FNG facility of 14MeV neutrons.

    Science.gov (United States)

    Capogni, M; Pietropaolo, A; Quintieri, L; Fazio, A; De Felice, P; Pillon, M; Pizzuto, A

    2018-04-01

    A severe supply crisis of 99 Mo, precursor of 99m Tc a diagnostic radionuclide largely used in Nuclear Medicine, occurred in 2008-2009 due to repeated shut-down of the two main (aged) fission reactors. An alternative route for producing 99 Mo by 100 Mo(n,2n) 99 Mo reaction was investigated at ENEA. The experiment, designed according to Monte Carlo simulations performed with the Fluka code, produced 99 Mo by irradiating a natural Molybdenum powdered target with 14MeV neutrons produced at the Frascati Neutron Generator. The 99 Mo specific activity was measured at metrological level by γ-ray spectrometry. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. BPW34 Commercial p-i-n Diodes for High-Level 1-MeV Neutron Equivalent Fluence Monitoring

    CERN Document Server

    Ravotti, F; Moll, M; Saigne, F

    2008-01-01

    The BPW34 p-i-n diode was characterized at CERN in view of its utilization as radiation monitor at the LHC to cover the broad 1-MeV neutron equivalent fluence (Phieq) range expected for the LHC machine and experiments during operation. Electrical measurements for both forward and reverse bias were used to characterize the device and to understand its behavior under irradiation. When the device is powered forward, a sensitivity to fast hadrons for Phieq > 2 times1012 cm-2 has been observed. With increasing particle fluences the forward I- V characteristics of the diode shifts towards higher voltages. At Phieq > 3times1013 cm-2, the forward characteristic starts to bend back assuming a thyristor-like behavior. An explanation for this phenomenon is given in this article. Finally, detailed radiation-response curves for the forward bias-operation and annealing studies of the diode's forward voltage are presented for proton, neutron and gamma irradiation.

  9. Statistical Model Analysis of (n, α Cross Sections for 4.0-6.5 MeV Neutrons

    Directory of Open Access Journals (Sweden)

    Khuukhenkhuu G.

    2016-01-01

    Full Text Available The statistical model based on the Weisskopf-Ewing theory and constant nuclear temperature approximation is used for systematical analysis of the 4.0-6.5 MeV neutron induced (n, α reaction cross sections. The α-clusterization effect was considered in the (n, α cross sections. A certain dependence of the (n, α cross sections on the relative neutron excess parameter of the target nuclei was observed. The systematic regularity of the (n, α cross sections behaviour is useful to estimate the same reaction cross sections for unstable isotopes. The results of our analysis can be used for nuclear astrophysical calculations such as helium burning and possible branching in the s-process.

  10. Non-destructive analysis of major components in plant materials by mean of 14-MeV neutrons; Analyse ''non destructrice'' des principaux constituants de la matiere vegetale apres irradiation aux neutrons de 14 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Garrec, J P [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1968-07-01

    Although reactors are an important source of neutrons for activation analysis, it is sometimes convenient to have recourse to other, less expensive neutron sources. The Centre d'Etudes Nucleaires at Grenoble has small electrostatic accelerators which generate fast neutrons of 14 MeV energy. These SAMES-type generators are used for directing a deuton beam at 150 kV onto a tritiated target, the resulting flux of monoenergetic neutrons attaining 5 x 10{sup 11} ns{sup -1} in 4 {pi} geometry by the {sup 3}H(d,n){sup 4}He reaction. Numerous elements found in plant material can be activated in this flux, mainly by (n,p), (n,{alpha}) and (n,2n) reactions. Current research is directed towards making use of the entire gamma spectrum of activated plant matter. A computer is used to break down the spectrum into seven main spectral regions by the least-squares method. As a first approximation, these regions are those obtained from aluminium, calcium, potassium, magnesium, phosphorus, silicon and chlorine standards in standard activation and radioactive decay conditions. The wanted advantage of this way of analysis is not acute sensibility, but great fastness. Therefore radioactivation with 14 MeV neutrons is particularly well adapted to quick and simultaneous dosages of useful elements in agronomy. (author) [French] Bien que les reacteurs constituent une source de neutrons importante en analyse par activation, il est parfois commode de recourir a d'autres sources neutronigenes exigeant un investissement moindre. Le Centre d'Etudes Nucleaires de Grenoble dispose de petits accelerateurs electrostatiques generateurs de neutrons rapides de 14 MeV. Ces generateurs, de type SAMES, accelerent un faisceau de deutons sous 150 kV vers une cible tritiee. Celle-ci fournit un flux de neutrons mono-energetiques atteignant 5 x 10{sup 11} n/s/4 {pi} par la reaction {sup 3}H(d,n){sup 4}He. De nombreux elements composant les matieres vegetales s'activent dans ce flux principalement par reactions

  11. Neutron yield and induced radioactivity: a study of 235-MeV proton and 3-GeV electron accelerators.

    Science.gov (United States)

    Hsu, Yung-Cheng; Lai, Bo-Lun; Sheu, Rong-Jiun

    2016-01-01

    This study evaluated the magnitude of potential neutron yield and induced radioactivity of two new accelerators in Taiwan: a 235-MeV proton cyclotron for radiation therapy and a 3-GeV electron synchrotron serving as the injector for the Taiwan Photon Source. From a nuclear interaction point of view, neutron production from targets bombarded with high-energy particles is intrinsically related to the resulting target activation. Two multi-particle interaction and transport codes, FLUKA and MCNPX, were used in this study. To ensure prediction quality, much effort was devoted to the associated benchmark calculations. Comparisons of the accelerators' results for three target materials (copper, stainless steel and tissue) are presented. Although the proton-induced neutron yields were higher than those induced by electrons, the maximal neutron production rates of both accelerators were comparable according to their respective beam outputs during typical operation. Activation products in the targets of the two accelerators were unexpectedly similar because the primary reaction channels for proton- and electron-induced activation are (p,pn) and (γ,n), respectively. The resulting residual activities and remnant dose rates as a function of time were examined and discussed. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  12. Effects of low doses of 14-MeV neutrons on the tensile properties of three binary copper alloys

    International Nuclear Information System (INIS)

    Heinisch, H.L.; Pintler, J.S.

    1986-12-01

    Miniature tensile specimens of high purity copper and copper alloyed respectively with five atom percent of Al, Mn, and Ni were irradiated with D-T fusion neutrons in the RTNS-II to fluences up to 1.3 x 10 18 n/cm 2 at 90 0 C. To compare fission and fusion neutron effects, some specimens were also irradiated at the same temperature to similar damage levels in the Omega West Reactor (OWR). Tensile tests were performed at room temperature, and the radiation-induced changes in tensile properties were examined as functions of displacements per atom (dpa). The irradiation-induced strengthening of Cu5%Mn is greater than that of Cu5%Al and Cu5%Ni, which behave about the same. However, all the alloys sustain less irradiation-induced strengthening by 14 MeV neutrons than pure copper, which is in contrast to the reported results of earlier work using hardness measurements. The effects of fission and fusion neutrons on the yield stress of Cu5%Al and Cu5%Ni correlate well on the basis of dpa, but the data for Cu5%Mn suggest that dpa may not be a good correlation parameter for this alloy in this fluence and temperature range

  13. Measurement method of activation cross-sections of reactions producing short-lived nuclei with 14 MeV neutrons

    CERN Document Server

    Kawade, K; Kasugai, Y; Shibata, M; Iida, T; Takahashi, A; Fukahori, T

    2003-01-01

    We describe a method for obtaining reliable activation cross-sections in the neutron energy range between 13.4 and 14.9 MeV for the reactions producing short-lived nuclei with half-lives between 0.5 and 30 min. We noted neutron irradiation fields and measured induced activities, including (1) the contribution of scattered low-energy neutrons, (2) the fluctuation of the neutron fluence rate during the irradiation, (3) the true coincidence sum effect, (4) the random coincidence sum effect, (5) the deviation in the measuring position due to finite sample thickness, (6) the self-absorption of the gamma-ray in the sample material and (7) the interference reactions producing the same radionuclides or the ones emitting the gamma-ray with the same energy of interest. The cross-sections can be obtained within a total error of 3.6%, when good counting statistics are achieved, including an error of 3.0% for the standard cross-section of sup 2 sup 7 Al (n, alpha) sup 2 sup 4 Na. We propose here simple methods for measuri...

  14. Neutron yield and induced radioactivity: a study of 235-MeV proton and 3-GeV electron accelerators

    International Nuclear Information System (INIS)

    Hsu, Yung-Cheng; Lai, Bo-Lun; Sheu, Rong-Jiun

    2016-01-01

    This study evaluated the magnitude of potential neutron yield and induced radioactivity of two new accelerators in Taiwan: a 235-MeV proton cyclotron for radiation therapy and a 3-GeV electron synchrotron serving as the injector for the Taiwan Photon Source. From a nuclear interaction point of view, neutron production from targets bombarded with high-energy particles is intrinsically related to the resulting target activation. Two multi-particle interaction and transport codes, FLUKA and MCNPX, were used in this study. To ensure prediction quality, much effort was devoted to the associated benchmark calculations. Comparisons of the accelerators' results for three target materials (copper, stainless steel and tissue) are presented. Although the proton-induced neutron yields were higher than those induced by electrons, the maximal neutron production rates of both accelerators were comparable according to their respective beam outputs during typical operation. Activation products in the targets of the two accelerators were unexpectedly similar because the primary reaction channels for proton- and electron-induced activation are (p,pn) and (γ,n), respectively. The resulting residual activities and remnant dose rates as a function of time were examined and discussed. (authors)

  15. Near term, low cost, 14 MeV fusion neutron irradiation facility for testing the viability of fusion structural materials

    Energy Technology Data Exchange (ETDEWEB)

    Kulcinski, Gerald L., E-mail: glkulcin@wisc.edu [University of Wisconsin-Madison, Madison, WI (United States); Radel, Ross F. [Phoenix Nuclear Labs LLC, Monona, WI (United States); Davis, Andrew [University of Wisconsin-Madison, Madison, WI (United States)

    2016-11-01

    For over 50 years, engineers have been looking for an irradiation facility that can provide a fusion reactor appropriate neutron spectrum over a significant volume to test fusion reactor materials that is relatively inexpensive and can be built in a minimum of time. The 14 MeV neutron irradiation facility described here can nearly exactly duplicate the neutron spectrum typical of a DT fusion reactor first wall at damage rates of ≈4 displacements per atom and 40 appm He generated over a 2 l volume per full power year of operation. The projected cost of this multi-beam facility is estimated at ≈$20 million and it can be built in <4 years. A single-beam prototype, funded by the U.S. Department of Energy, is already being built to produce medical isotopes. The neutrons are produced by a 300 keV deuterium beam accelerated into 4 kPa (30 Torr) tritium target. The total tritium inventory is <2 g and <0.1 g of T{sub 2} is consumed per year. The core technology proposed has already been fully demonstrated, and no new plasma physics or materials innovations will be required for the test facility to become operational.

  16. Measurements of the prompt neutron spectra in 233U, 235U, 239Pu thermal neutron fission in the energy range of 0.01-5 MeV and in 252Cf spontaneous fission in the energy range of 0.01-10 MeV

    International Nuclear Information System (INIS)

    Starostov, B.I.; Semenov, A.F.; Nefedov, V.N.

    1978-01-01

    The measurement results on the prompt neutron spectra in 233 U, 235 U, 239 Pu thermal neutron fission in the energy range of 0.01-5 MeV and in 252 Cf spontaneous fission in the energy range of 0.01-10 MeV are presented. The time-of-flight method was used. The exceeding of the spectra over the Maxwell distributions is observed at E 252 Cf neutron fission spectra. The spectra analysis was performed after normalization of the spectra and corresponding Maxwell distributions for one and the same area. In the range of 0.05-0.22 MeV the yield of 235 U + nsub(t) fission neutrons is approximately 8 and approximately 15 % greater than the yield of 252 Cf and 239 Pu + nsub(t) fission neutrons, respectively. In the range of 0.3-1.2 MeV the yield of 235 U + nsub(t) fission neutrons is 8 % greater than the fission neutron yield in case of 239 Pu + nsub(t) fission. The 235 U + nsub(t) and 233 U + nsub(t) fission neutron spectra do not differ from one another in the 0.05-0.6 MeV range

  17. Fission Product Yields for 14 MeV Neutrons on 235U, 238U and 239Pu

    International Nuclear Information System (INIS)

    Mac Innes, M.; Chadwick, M.B.; Kawano, T.

    2011-01-01

    We report cumulative fission product yields (FPY) measured at Los Alamos for 14 MeV neutrons on 235 U, 238 U and 239 Pu. The results are from historical measurements made in the 1950s–1970s, not previously available in the peer reviewed literature, although an early version of the data was reported in the Ford and Norris review. The results are compared with other measurements and with the ENDF/B-VI England and Rider evaluation. Compared to the Laurec (CEA) data and to ENDF/B-VI evaluation, good agreement is seen for 235 U and 238 U, but our FPYs are generally higher for 239 Pu. The reason for the higher plutonium FPYs compared to earlier Los Alamos assessments reported by Ford and Norris is that we update the measured values to use modern nuclear data, and in particular the 14 MeV 239 Pu fission cross section is now known to be 15–20% lower than the value assumed in the 1950s, and therefore our assessed number of fissions in the plutonium sample is correspondingly lower. Our results are in excellent agreement with absolute FPY measurements by Nethaway (1971), although Nethaway later renormalized his data down by 9% having hypothesized that he had a normalization error. The new ENDF/B-VII.1 14 MeV FPY evaluation is in good agreement with our data.

  18. Model calculation of neutron reaction data for {sup 31}P in the energy range from 0.1 to 20 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Jiangting, Li [Physics Department, Northwest Univ., Xi' an (China); Zhigang, Ge [China Nuclear Data Center, China Inst. of Atomic Energy, Beijing (China); Xiuquan, Sun [Engineering and Technology Department, Shenzhen University, Shenzhen (China)

    2006-07-15

    The neutron data calculation of {sup 31}P in the energy range from 0.1 to 20 MeV was carried out. The neutron optical potential parameters for {sup 31}P in energy range from O.1 to 20 MeV were obtained, based on the fitting of the available neutron experimental data with the code APOM94. The DWUCK4 code was used to investigate the cross section for neutron direct inelastic scattering. The re-evaluated neutron data is based on the available measured data by using the UNF code. The theoretical results reproduce the experimental data well, and the results were given in ENDF/B-6 format. (authors)

  19. Measurement of (n,α) cross-sections for Cr, Fe and Ni at 14 MeV neutron energy

    International Nuclear Information System (INIS)

    Wattecamps, E.; Liskien, H.; Arnotte, F.

    1983-01-01

    Helium production cross-sections for the main constituents of stainless steel (Cr, Fe, Ni) have recently been published for neutron energies between 5 and 10 MeV. The α-particles were detected with a multi-angle telescope and cross-section data relative to the well known n-p scattering cross-section were deduced. Those measurements have been performed now also at 14 MeV. At this energy the background condition had to be improved by changing the neutron collimation, by reducing the sensitive volume of the ΔE-proportional counters, and by replacing remaining low-Z material inside the chamber by tantalum. Listing mode data acquisition is used and α-particle identification is performed by transforming the observed (ΔE,E) signal into a (MZ 2 ,E) signal. The measurements yield the angle-differential cross sections for five fixed angles. Angle-integrated cross-sections are compared with the few results available in literature. (Auth.)

  20. Design of an irradiation facility with thermal, epithermal and fast neutron beams

    International Nuclear Information System (INIS)

    Pfister, G.; Bernnat, W.; Seidel, R.; Schatz, A.K.; Wagner, F.M.; Waschkowski, W.; Schraube, H.

    1992-01-01

    The main features of a neutron irradiation facility to be installed at the planned research reactor FRM-II are presented. In addition to the operational possibilities of the existing facility at the reactor FRM-I, the new facility will produce quasi-monoenergetic neutron fields and a neutron beam in the keV region whose spectrum can be modified by application of suitable filters and scatterers. For this beam, which is well suited for boron capture therapy, calculated boron reaction rates inside a phantom and an experimental verification of the calculations at the existing facility are presented. (orig.) [de

  1. Evaluated cross-section libraries and kerma factors for neutrons up to 100 MeV on 12C

    International Nuclear Information System (INIS)

    Chadwick, M.B.; Blann, M.; Cox, L.; Young, P.G.; Meigooni, A.

    1995-01-01

    A program is being carried out at Lawrence Livermore National Laboratory to develop high-energy evaluated nuclear data libraries for use in Monte Carlo simulations of cancer radiation therapy. In this report we describe evaluated cross sections and kerma factors for neutrons with incident energies up to 100 MeV on 12 C. The aim of this effort is to incorporate advanced nuclear physics modeling methods, with new experimental measurements, to generate cross section libraries needed for an accurate simulation of dose deposition in fast neutron therapy. The evaluated libraries are based mainly on nuclear model calculations, benchmarked to experimental measurements where they exist. We use the GNASH code system, which includes Hauser-Feshbach, preequilibrium, and direct reaction mechanisms. The libraries tabulate elastic and nonelastic cross sections, angle-energy correlated production spectra for light ejectiles with A≤and kinetic energies given to light ejectiles and heavy recoil fragments. The major steps involved in this effort are: (1) development and validation of nuclear models for incident energies up to 100 MeV; (2) collation of experimental measurements, including new results from Louvain-la-Nueve and Los Alamos; (3) extension of the Livermore ENDL formats for representing high-energy data; (4) calculation and evaluation of nuclear data; and (5) validation of the libraries. We describe the evaluations in detail, with particular emphasis on our new high-energy modeling developments. Our evaluations agree well with experimental measurements of integrated and differential cross sections. We compare our results with the recent ENDF/B-VI evaluation which extends up to 32 MeV

  2. Determination of neutron spectra formed by 40-MeV deuteron bombardment of a lithium target with multi-foil activation technique

    CERN Document Server

    Maekawa, F; Wada, M; Wilson, P P H; Ikeda, Y

    2000-01-01

    Neutron flux spectra at an irradiation field produced by a 40-MeV deuteron bombardment on a thick lithium-target at Forschungszentrum Karlsruhe, Germany, have been determined by the multi-foil activation technique. Twenty-seven dosimetry reactions having a wide energy range of threshold energies up to 38 MeV were employed as detectors for the neutron flux spectra extending to 55 MeV. The spectra were adjusted with the SAND-II code with the experimental reaction rates based on an iterative method. The adjusted spectra validated quantitatively the Monte Carlo deuteron-lithium (d-Li) neutron source model code (M sup C DeLi) which was used to calculate initial guess spectra and also has been used for IFMIF nuclear designs. Accuracy of the adjusted spectra was approx 10% that was suitable for successive integral tests of activation cross section data.

  3. Study of the neutron-proton interaction in the 300 to 700 MeV energy region. Annual progress report (1985-1986)

    International Nuclear Information System (INIS)

    Northcliffe, L.C.

    1986-01-01

    Results obtained for experiments conducted at the LAMPF are reported. All of these experiments utilize the LAMPF polarized (50%) neutron beam and hydrogen targets. Measurements are reported for spin-correlation parameters (500 to 800 MeV, 13 GeV/c, 18.5 GeV/c) and the analyzing power (800 MeV) for n-p elastic scattering. The status of earlier LAMPF experiments by this group are also included

  4. Cross section of the {sup 11}B(n,p) {sup 11}Be reaction for 14.7-16.9 MeV neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Stepancinc, B Z; Stanojevic, D M; Popic, V R; Aleksic, M R [Institute of nuclear sciences Boris Kidric, Vinca, Beograd (Serbia and Montenegro)

    1966-07-15

    The cross section of the {sup 11}B(n,p){sup 11}Be reaction was determined for neutron energy range from 14.7 to 16.9 MeV using the activation method. Activity measurements were done by using a coincidence spectrometer essentially consisting of two plastic scintillators. Energy dependent cross section values are presented together with the previously measured values for the energy range 14.5 - 16.9 MeV.

  5. Neutron-induced fission cross-section of 233U, 241Am and 243Am in the energy range 0.5 MeV ≤ En ≤ 20 MeV

    International Nuclear Information System (INIS)

    Belloni, F.; Milazzo, P.M.; Calviani, M.

    2011-01-01

    Neutron-induced fission cross-sections of 233 U, 241 Am and 243 Am relative to 235 U have been measured in a wide energy range at the neutron time of flight facility n-TOF in Geneva to address the present discrepancies in evaluated and experimental databases for reactions and isotopes relevant for transmutation and new generation fast reactors. A dedicated fast ionization chamber was used. Each isotope was mounted in a different cell of the modular detector. The measurements took advantage of the characteristics of the n-TOF installation. Its intrinsically low background, coupled to its high instantaneous neutron flux, results in high accuracy data. Its wide energy neutron spectrum helps to reduce systematic uncertainties due to energy-domain matching problems while the 185 m flight path and a 6 ns pulse width assure an excellent energy resolution. This paper presents results obtained between 500 keV and 20 MeV neutron energy. (authors)

  6. Total neutron cross sections at energies around 20 MeV

    International Nuclear Information System (INIS)

    Morales, J.R.; Romero, J.L.; Martens, P.

    1990-09-01

    The results for measurements of total cross sections on C, Al, Mg, Cu, Ge and Pb at 17.6 and 19.8 MeV are reported. A detailed comparison is presented with previous data and with the global optical model by the Ohio group. We also discuss plans for total non elastic cross section measurements. 31 refs, 12 figs, 2 tabs

  7. In vivo skin leptin modulation after 14 MeV neutron irradiation: a molecular and FT-IR spectroscopic study

    Energy Technology Data Exchange (ETDEWEB)

    Cestelli Guidi, M.; Mirri, C.; Marcelli, A. [Laboratori Nazionali di Frascati - INFN, Frascati, Rome (Italy); Fratini, E.; Amendola, R. [ENEA, UT BIORAD-RAB, Rome (Italy); Licursi, V.; Negri, R. [Universita La Sapienza, Dip. Biologia e Biotecnologie ' ' Charles Darwin' ' , Rome (Italy)

    2012-09-15

    This paper discusses gene expression changes in the skin of mice treated by monoenergetic 14 MeV neutron irradiation and the possibility of monitoring the resultant lipid depletion (cross-validated by functional genomic analysis) as a marker of radiation exposure by high-resolution FT-IR (Fourier transform infrared) imaging spectroscopy. The irradiation was performed at the ENEA Frascati Neutron Generator (FNG), which is specifically dedicated to biological samples. FNG is a linear electrostatic accelerator that produces up to 1.0 x 10{sup 11} 14-MeV neutrons per second via the D-T nuclear reaction. The functional genomic approach was applied to four animals for each experimental condition (unirradiated, 0.2 Gy irradiation, or 1 Gy irradiation) 6 hours or 24 hours after exposure. Coregulation of a subclass of keratin and keratin-associated protein genes that are physically clustered in the mouse genome and functionally related to skin and hair follicle proliferation and differentiation was observed. Most of these genes are transiently upregulated at 6 h after the delivery of the lower dose delivered, and drastically downregulated at 24 h after the delivery of the dose of 1 Gy. In contrast, the gene coding for the leptin protein was consistently upregulated upon irradiation with both doses. Leptin is a key protein that regulates lipid accumulation in tissues, and its absence provokes obesity. The tissue analysis was performed by monitoring the accumulation and the distribution of skin lipids using FT-IR imaging spectroscopy. The overall picture indicates the differential modulation of key genes during epidermis homeostasis that leads to the activation of a self-renewal process at low doses of irradiation. (orig.)

  8. In vivo skin leptin modulation after 14 MeV neutron irradiation: a molecular and FT-IR spectroscopic study.

    Science.gov (United States)

    Cestelli Guidi, M; Mirri, C; Fratini, E; Licursi, V; Negri, R; Marcelli, A; Amendola, R

    2012-09-01

    This paper discusses gene expression changes in the skin of mice treated by monoenergetic 14 MeV neutron irradiation and the possibility of monitoring the resultant lipid depletion (cross-validated by functional genomic analysis) as a marker of radiation exposure by high-resolution FT-IR (Fourier transform infrared) imaging spectroscopy. The irradiation was performed at the ENEA Frascati Neutron Generator (FNG), which is specifically dedicated to biological samples. FNG is a linear electrostatic accelerator that produces up to 1.0 × 10(11) 14-MeV neutrons per second via the D-T nuclear reaction. The functional genomic approach was applied to four animals for each experimental condition (unirradiated, 0.2 Gy irradiation, or 1 Gy irradiation) 6 hours or 24 hours after exposure. Coregulation of a subclass of keratin and keratin-associated protein genes that are physically clustered in the mouse genome and functionally related to skin and hair follicle proliferation and differentiation was observed. Most of these genes are transiently upregulated at 6 h after the delivery of the lower dose delivered, and drastically downregulated at 24 h after the delivery of the dose of 1 Gy. In contrast, the gene coding for the leptin protein was consistently upregulated upon irradiation with both doses. Leptin is a key protein that regulates lipid accumulation in tissues, and its absence provokes obesity. The tissue analysis was performed by monitoring the accumulation and the distribution of skin lipids using FT-IR imaging spectroscopy. The overall picture indicates the differential modulation of key genes during epidermis homeostasis that leads to the activation of a self-renewal process at low doses of irradiation.

  9. Energy dependence of relative abundances and periods of separate groups of delayed neutrons at neutron induced fission of 239Pu in a range of neutrons energies 0.37 - 5 MeV

    International Nuclear Information System (INIS)

    Roschenko, V.A.; Piksaikin, V.M.; Kazakov, L.E.; Isaev, S.G.; Korolev, G.G.; Tarasko, M.Z.; Tertychnyi, R.G.

    2001-01-01

    The fundamental role of delayed neutrons in behavior, control and safety of reactors is well known today. Delayed neutron data are of great interest not only for reactor physics but also for nuclear fission physics and astrophysics. The purpose of the present work was the measurement of energy dependence of delayed neutrons (DN) group parameters at fission of nuclei 239 Pu in a range of energies of primary neutrons from 0.37 up to 5 MeV. The measurements were executed on installation designed on the basis of the electrostatic accelerator of KG - 2.5 SSC RF IPPE. The data are obtained in 6-group representation. It is shown, that there is a significant energy dependence of DN group parameters in a range of primary neutrons energies from thermal meanings up to 5 MeV, which is expressed in reduction of the average half-life of nuclei of the DN precursors on 10 %. The data, received in the present work, can be used at creation of a set of group constants for reactors with an intermediate spectrum of neutrons. (authors)

  10. Study on measurement technique contrast of 14 MeV neutron fluence

    International Nuclear Information System (INIS)

    Jiang Li; Hu Jun; Wen Dezhi

    2005-10-01

    The stability and repetition of the associated-particle method to measure DT neutron fluence was tested. The neutron activation iron method was contrasted with the associated-particle method, the preparatory experiment was done. The neutron fluence measured with associated-particle method was contrasted with neutron activation Al method, the Al activated foil was measured with 4πβ (PC)-γ coincidence standard device. The contrast result's standard deviation of the two method was less than the expand uncertainty of the associated-particle method. Therein, the uncertainty of the associated-particle method is 1.6%, the uncertainty of the activation Al method is 1.8%. (authors)

  11. Removal cross section for 14 MeV neutrons in constructional materials

    International Nuclear Information System (INIS)

    Vasvary, L.; Divos, F.; Peto, G.; Csikai, J.; Mumba, N.K.

    1986-01-01

    Using flight time difference the direct and scattered neutrons and gammas produced in the target head and samples were separated. With this method the attenuation of primary neutrons and gammas originating from the target head has been studied. Thickness dependence of the secondary gamma yield from extended samples of Al, Fe, Pb, paraffin and reinforced concrete was also measured. Results indicate a geometry dependence of the removal cross sections. (author)

  12. The differential elastic scattering of 14.7 MeV neutron from beryllium

    International Nuclear Information System (INIS)

    Zhang Kun; Cao Jianhua; Wan Dairong; Dai Yunsheng

    1995-01-01

    A fast neutron associated particle time-of-flight (TOF) spectrometer was used for measuring neutron differential cross sections on beryllium nuclei in this experiment. The total error of the differential cross section is from 7.5% to 11.5% including the statistical error 0.5∼3.5 and the efficiency calibration error 6∼7%. (2 tabs., 1 fig)

  13. Container inspection in the port container terminal by using 14 MeV neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Valkovic, Vladivoj [Institute Ruder Boskovic, Zagreb (Croatia); Kvinticka 62, Zagreb (Croatia); Sudac, Davorin; Nad, Karlo; Obhodas, Jasmina [Ruder Boskovic Institute, Bijenicka c.54, Zagreb (Croatia)

    2015-07-01

    A proposal for an autonomous and flexible ship container inspection system is presented. This could be accomplished by the incorporation of inspection system on the container transportation devices (straddle carriers, yard gentry cranes automated guided vehicles, trailers). This configuration is terminal specific and it will be decided by container terminal operator. In such a way no part of port operational area will be used for inspection. The inspection scenario will include container transfer from ship to transportation device with inspection unit mounted on it, inspection during container movement to the container location. A neutron generator without associated alpha particle detection will be used. This will allow the use of higher neutron intensity (5x10{sup 9} - 10{sup 10} n/s in 4π). The inspected container will be stationary in the 'inspection position' on the transportation device while the 'inspection unit' will move along its side. Following analytical methods will be used simultaneously: neutron radiography, X-ray radiography, neutron activation analysis, (n,γ) and (n,n'γ) reactions, neutron absorption, and scattering, X-ray backscattering, Neutron techniques will take the advantage of using 'smart collimators' for neutrons and gammas, both emitted and detected. The inspected voxel will be defined by intersections/union of neutron generator and detectors solid angles. The container inspection protocol will be based on identification of discrepancies between its cargo manifest and its elemental 'fingerprint' and radiography profiles. In addition, the information on container weight will be obtained during the container transport and foreseen screening from the measurement of density of material in the container. (authors)

  14. Differential cross sections for carbon neutron elastic and inelastic scattering from 8.0 to 14.5 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Haouat, G.; Lachkar, J.; Patin, Y.; Sigaud, J.; Cocu, F.

    1975-06-01

    Differential elastic and inelastic cross sections for fast neutrons scattered by carbon have been measured between 8.0 and 14.5 MeV. No experimental results on {sup 12}C seem to have been reported, at this time, between 9 and 14 MeV. A complete and consistent set of data on carbon, including total, elastic and inelastic, (n,α) and (n,n'3α) cross sections, is now available for energies below 14.5MeV.

  15. Measurements of the Fe-54 (n,p) Mn-54 Reaction Cross Section in the Neutron Energy Range 2.3-3.8 MeV

    International Nuclear Information System (INIS)

    Lauber, A.; Malmskog, S.

    1964-10-01

    We have measured the 54 Fe (n, p) 54 Mn reaction cross section using a surface barrier detector to record the number of protons released in the reaction. The neutron flux was determined by means of a hydrogenous radiator, detecting the scattered protons with the solid state detector, and calculating the number of impinging neutrons from the well known n-p scattering cross section. The 54 Fe (n, p) 54 Mn reaction cross section is found to increase from 25 mb at 2.3 MeV to 208 mb at 3.5 MeV

  16. Measurements of neutron emission spectra and 7Be production in Li(d, n) and Be(d, n) reactions for 25 and 40 MeV deuterons

    International Nuclear Information System (INIS)

    Hagiwara, Masayuki; Baba, Mamoru; Aoki, Takao; Kawata, Naoki; Hirabayashi, Naoya; Itoga, Toshiro

    2003-01-01

    The neutron spectra in Li(d, n) and Be(d, n) reactions for Ed = 25, 40 MeV were measured from ∼1 MeV to highest energy of secondary neutrons at ten laboratory angles between 0- and 110-deg with the time-of-flight (TOF) method. In addition, the number of 7 Be accumulated in the targets was also measured by counting the γ-rays from 7 Be using a pure Ge detector to obtain 7 Be production cross-section and yields. (author)

  17. Neutron Elastic Scattering Cross Sections of Iron and Zinc in the Energy Region 2.5 to 8.1 MeV

    International Nuclear Information System (INIS)

    Holmqvist, B.; Johansson, S.G.; Lodin, G.; Wiedling, T.; Kiss, A.

    1966-12-01

    Angular distributions were measured for the elastic scattering of neutrons from iron at five energies between 3.0 and 8. 1 MeV and from zinc at eight energies between 2.5 and 8.1 MeV. Time-of-flight technique was used. Corrections for neutron flux attenuation, multiple elastic scattering, and the finite geometry of the source-sample detector system were made by using a Monte Carlo program. An optical model potential with Saxon-Woods form factors was used to fit theoretical angular distributions to the experimental ones. The parameter values giving the best fits to the experimental distributions were calculated by a computer

  18. Measurements of the Fe-54 (n,p) Mn-54 Reaction Cross Section in the Neutron Energy Range 2.3-3.8 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Lauber, A; Malmskog, S

    1964-10-15

    We have measured the {sup 54}Fe (n, p) {sup 54}Mn reaction cross section using a surface barrier detector to record the number of protons released in the reaction. The neutron flux was determined by means of a hydrogenous radiator, detecting the scattered protons with the solid state detector, and calculating the number of impinging neutrons from the well known n-p scattering cross section. The {sup 54}Fe (n, p) {sup 54}Mn reaction cross section is found to increase from 25 mb at 2.3 MeV to 208 mb at 3.5 MeV.

  19. Neutron Elastic Scattering Cross Sections of Iron and Zinc in the Energy Region 2.5 to 8.1 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Holmqvist, B; Johansson, S G; Lodin, G; Wiedling, T [AB Atomenergi, Nyko eping (Sweden); Kiss, A [Inst. for Experimental Physics, Univ. of Debrecen, De brecen (Hungary)

    1966-12-15

    Angular distributions were measured for the elastic scattering of neutrons from iron at five energies between 3.0 and 8. 1 MeV and from zinc at eight energies between 2.5 and 8.1 MeV. Time-of-flight technique was used. Corrections for neutron flux attenuation, multiple elastic scattering, and the finite geometry of the source-sample detector system were made by using a Monte Carlo program. An optical model potential with Saxon-Woods form factors was used to fit theoretical angular distributions to the experimental ones. The parameter values giving the best fits to the experimental distributions were calculated by a computer.

  20. Neutron activation of 21 elements by means of the Mg+d reaction (Esub(d) 22 Mev)

    International Nuclear Information System (INIS)

    Zatolokin, B.V.; Krasnov, N.N.; Konstantinov, I.O.; Bolotskikh, V.I.

    1981-01-01

    For the first time the activation of 21 elements (Mn, Al, Ti, V, Cr, Mg, Fe, Co, Ni, Cu, Zn, Zr, Nb, Mo, Ag, Cd, Sn, Sb, Ta, W and Pb) by neutrons produced as a result of magnesium target irradiation by deuterons at 22 MeV energy is investigated. The reduced exposure dose rates of point samples of 1 g mass at 1 cm distance from a source are presented. The data on variation in time of exposure dose rates of 1 g mass samples irradiated during 100 hours are indicated. In the framework of a two-group approximation the neutron spectrum is estimated by the results of measurement of two threshold detector activity. It is shown that for the first hours after irradiation Mn, Mg, Al, W, Cu and Ta have the highest exposure dose rates, Cr, Pb, Cd and Sn - the lowest. In four days after irradiation Sb, Ta, Co, Ag and Ti have the highest dose rates, Pb, Fe, Cu and Cr - the lowest. The data obtained can be used in constructing separate accelerator units and in fast neutron activation analysis [ru

  1. Increase of the electrical resistance of thin copper film due to 14 MeV neutron irradiation

    International Nuclear Information System (INIS)

    Agrawal, S.K.; Kumar, U.; Nigam, A.K.; Singh, S.P.

    1981-01-01

    The variation in the electrical resistance of thin copper film (500 A 0 thick), grown on the glass slide has been measured with increasing 14 MeV neutron irradiation time. The electrical resistance vs irradiation time curve shows an interesting behaviour after an irradiation of 40 minutes. However, there is a net increase in the electrical resistance with increasing neutron dose. The maximum increase in the observed electrical resistance after an irradiation of 115 mins, is 4.45%. The microstructural studies of irradiated film were made using TEM and TED techniques. The TEM patterns up to an irradiation time of 1.00 hr do not show any appreciable change in the microstructure. The TED patterns also do not show any appreciable change in the diffraction pattern up to an irradiation time of 1.0 hr. But after an irradiation time of 1.5 hrs, two extra rings appear in the TED pattern which disappear with increasing neutron irradiation time

  2. Evaluation of 242Pu data for the incident neutron energy range 0.1 - 6 MeV

    International Nuclear Information System (INIS)

    Vladuca, G.; Sin, M.; Tudora, A.

    1996-11-01

    This report presents the models and the procedures used for the calculation of the quantities required by Files 3, 4 and 5 of ENDF-6 for 242 Pu. These quantities are the integrated cross sections for the total, fission, scattering and gamma-capture reactions and the angular and energy distributions of the scattered neutrons for the incident neutron energies 0.01/6 MeV. The direct mechanism was treated with the coupled-channel method using a deformed optical potential defined by a set of actinide region parameters established by the authors. For the compound nucleus calculations, a new HRTW version of the statistical model extended to describe the fission at subbarrier energies was used. To describe the continuous part of the transition states spectrum, analytical expressions have been established. The energy distributions of the scattered neutrons have been calculated with an author's version of the Los Alamos model. The agreement of the calculations with the existing experimental data is good. (author)

  3. Neutron activation analysis with pulsed 14 MeV neutrons for the characterization of heterogeneous radioactive wastes; Neutronenaktivierungsanalyse mit gepulsten 14 MeV Neutronen zur Charakterisierung heterogener radioaktiver Abfaelle

    Energy Technology Data Exchange (ETDEWEB)

    Mildenberger, Frank

    2017-07-01

    For the transport, interim storage and disposal of radioactive waste, it is assumed to have knowledge of the radioactive and non-radioactive inventory. In order to determine the radioactive inventory destructive (e.g. α-, β-, γ-measurements according to wet chemical sample preparation) and non-destructive (e.g. γ-scanning and neutron measurements) measurement methods are used. For the characterization of non-radioactive substances a prototype for the assay of small-volume (50 L) samples was constructed and parameterized using the neutron activation analysis (NAA) with a pulsed 14 MeV neutron source. Subsequently, the non-destructive analytical method called MEDINA (Multi Element Detection Based on Instrumental Neutron Activation) for 200 l waste drums was developed in a cooperation between RWTH Aachen University and Forschungszentrum Juelich GmbH. The aim of this thesis is to investigate and characterize heterogeneous mixed samples regarding their material composition as well as their inhomogeneous distribution. For this purposes, studies were carried out on 200 l steel drums with heterogeneous matrices using the NAA in the MEDINA facility. The samples are composed out of a mixture of concrete and polyethylene (PE) bodies. Due to its high hydrogen content, the PE can have a strong influence on the neutron moderation and neutron absorption and can thereby occur as a possible disturbance variable in the characterization of the non-radioactive inventory. For these studies a pulsed 14 MeV neutron source is used to record the prompt and delayed γ-rays between the neutron pulses, separately. Thus, the performance of the MEDINA method relating to strongly moderating mixed matrices and their characterization is studied. In order to optimize the measurement of delayed γ-rays without any appreciable interference of prompt γ-rays, the decay of thermal neutrons was studied and the thermal neutron die-away time was determined. It ranges between 2 and 5 ms according to

  4. Cross-sections for formation of {sup 89}Zr{sup m} through {sup 90}Zr(n,2n){sup 89}Zr{sup m} reaction over neutron energy range 13.73 MeV to 14.77 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Attar, F.M.D. [Department of Physics, University of Pune, Pune-411007 (India); Mandal, R. [Department of Physics, University of Pune, Pune-411007 (India); Indian Institute of Technology, Kharagpur (India); Dhole, S.D. [Department of Physics, University of Pune, Pune-411007 (India); Saxena, A. [Nuclear Physics Division, BARC, Mumbai (India); Ashokkumar,; Ganesan, S. [Reactor Physics Design Division, BARC, Mumbai (India); Kailas, S. [Nuclear Physics Division, BARC, Mumbai (India); Bhoraskar, V.N. [Department of Physics, University of Pune, Pune-411007 (India)], E-mail: vnb@physics.unipune.ernet.in

    2008-04-01

    The cross-sections for formation of metastable state of {sup 89}Zr ({sup 89}Zr{sup m}, 0.588 MeV, 4.16 m) through {sup 90}Zr(n,2n){sup 89}Zr{sup m} reaction induced by 13.73 MeV to 14.77 MeV neutrons were measured for the first time and also theoretically estimated using Empire-II and Talys programs. At 13.73 MeV neutron energy, the {sup 89}Zr nuclei can be excited to metastable state, {sup 89}Zr{sup m}, when the first and the second emitted neutrons have energies lower than the most probable energy {approx}0.64 MeV. The probability of exciting {sup 89}Zr nuclei to energy levels higher than 0.588 MeV and therefore of populating the metastable state through decay process increases with increasing neutron energy. The measured cross-sections vary from 41{+-}3mb to 221{+-}15mb over neutron energies 13.73 MeV to 14.77 MeV, and are in agreement with the cross-sections estimated using Empire-II code. The formation of {sup 89}Zr{sup m} is favoured when the first and the second reaction neutrons are emitted with the most probable energies rather than lower energy, except for 13.73 MeV neutrons.

  5. Measurements of attenuation lengths through concrete and iron for neutrons produced by 800-MeV proton on tantalum target at ISIS

    CERN Document Server

    Nunomiya, T; Wright, P; Nakamura, T; Kim, E; Kurosawa, T; Taniguchi, S; Sasaki, M; Iwase, H; Uwamino, Y; Shibata, T; Ito, S; Perry, D R

    2002-01-01

    A deep penetration experiment through a thick bulk shield was performed at an intense spallation neutron source facility, ISIS, of the Rutherford Appleton Laboratory (RAL), United Kingdom. ISIS is a 800 MeV-200 mu A proton accelerator facility. Neutrons are produced from a tantalum target, and are shielded with approximately 3-m thick steel and 1-m thick ordinary concrete. On top of the shield, we measured the neutron flux attenuation through concrete and iron shields, which were additionally placed up to 120-cm and 60-cm thickness, respectively, using activation detectors of graphite and bismuth. The attenuation lengths of concrete and iron for high-energy neutrons above 20 MeV were obtained from the sup 1 sup 2 C(n, 2n) sup 1 sup 1 C reaction of graphite.

  6. Neutron induced fission cross section ratios for 232Th, 235,238U, 237Np and 239Pu from 1 to 400 MeV

    International Nuclear Information System (INIS)

    Lisowski, P.W.; Ullmann, J.L.; Balestrini, S.J.; Carlson, A.D.; Wasson, O.A.; Hill, N.W.

    1988-01-01

    Time-of-flight measurements of neutron induced fission cross section ratios for 232 Th, 235,238 U, 237 Np, and 239 Pu, were performed using the WNR high intensity spallation neutron source located at Los Alamos National Laboratory. A multiple-plate gas ionization chamber located at a 20-m flight path was used to simultaneously measure the fission rate for all samples over the energy range from 1 to 400 MeV. Because the measurements were made with nearly identical neutron fluxes, we were able to cancel many systematic uncertainties present in previous measurements. This allows us to resolve discrepancies among different data sets. In addition, these are the first neutron-induced fission cross section values for most of the nuclei at energies above 30 MeV. (author)

  7. Neutron induced fission cross section ratios for 232Th, /sup 235,238/U, 237Np, and 239Pu from 1 to 400 MeV

    International Nuclear Information System (INIS)

    Lisowski, P.W.; Ullmann, J.L.; Balestrini, S.J.; Carlson, A.D.; Wasson, O.A.; Hill, N.W.

    1988-01-01

    Time-of-flight measurements of neutron induced fission cross section ratios for 232 Th, /sup 235,238/U, 237 Np, and 239 Pu, were performed using the WNR high intensity spallation neutron source located at Los Alamos National Laboratory. A multiple-plate gas ionization chamber located at a 20-m flight path was used to simultaneously measure the fission rate for all samples over the energy range from 1 to 400 MeV. Because the measurements were made with nearly identical neutron fluxes, we were able to cancel many systematic uncertainties present in previous measurements. This allows us to resolve discrepancies among different data sets. In addition, these are the first neutron-induced fission cross section values for most of the nuclei at energies above 30 MeV. 8 refs., 3 figs

  8. Neutron fluence in a 18 MeV Electron Accelerator for Therapy

    International Nuclear Information System (INIS)

    Paredes G, L.C.

    2001-01-01

    An investigation was made on the theoretical fundamentals for the determination of the neutron fluence in a linear electron accelerator for radiotherapy applications and the limit values of leakage neutron radiation established by guidelines and standards in radiation protection for these type of accelerators. This investigation includes the following parts: a) Exhaustive bibliographical review on the topics mentioned above, in order to combine and to update the necessary basic information to facilitate the understanding of this subject; b) Analysis of the accelerator operation and identification of its main components, specially in the accelerator head; c) Study of different types of targets and its materials for the Bremsstrahlung production which is based on the electron initial energy, the thickness of the target, and its angular distribution and energy, which influences in the neutron generation by means of the photonuclear and electro disintegration reactions; d) Analysis of the neutron yield based on the target type and its thickness, the energy of electrons and photons; e) Analysis of the neutron energy spectra generated in the accelerator head, inside and outside the treatment room; f) Study of the dosimetry fundamentals for neutron and photon mixed fields, the dosimeter selection criteria and standards applied for these applications, specially the Panasonic U D-809 thermoluminescent dosemeter and C R-39 nuclear track dosimeter; g) Theoretical calculation of the neutron yield using a simplified geometric model for the accelerator head with spherical cell, which considers the target, primary collimator, flattener filter, movable collimators and the head shielding as the main components for radiation production. The cases with W and Pb shielding for closed movable collimators and an irradiation field of 20 x 20 cm 2 were analyzed and, h) Experimental evaluation of the leakage neutron radiation from the patient and head planes, observing that the accelerator

  9. Irradiations of human melanoma cells by 14 MeV neutrons; survival curves interpretation; physical simulation of neutrons interactions in the cellular medium

    International Nuclear Information System (INIS)

    Bodez, Veronique

    2000-01-01

    14 MeV neutrons are used to irradiate human melanoma cells in order to study survival curves at low dose and low dose rate. We have simulated with the MCNP code, transport of neutrons through the experimental setup to evaluate the contamination of the primary beam by gamma and electrons, for the feasibility of our experiments. We have shown a rapid decrease of the survival curve in the first cGy followed by a plateau for doses up to 30 cGy; after we observed an exponential decrease. This results are observed for the first time, for neutrons at low dose rate (5 cGy/h). In parallel with this experimental point, we have developed a simulation code which permitted the study of neutrons interactions with the cellular medium for individual cells defined as in our experimental conditions. We show that most of the energy is deposited by protons from neutron interactions with external medium, and by heavy ions for interactions into the cell. On the other hand the code gives a good order of magnitude of the dose rate, compared to the experimental values given by silicon diodes. The first results show that we can, using a theory based on induced repair of cells, give an interpretation of the observed experimental plateau. We can give an estimation of the radial distribution of dose for the tracks of charged ions, we show the possibility of calculate interaction cross sections with cellular organelles. Such a work gives interesting perspectives for the future in radiobiology, radiotherapy or radioprotection. (author) [fr

  10. Nuclear data evaluations of neutron and proton incidence on Zr, Nb, and W for energy up to 200 MeV

    International Nuclear Information System (INIS)

    Kunieda, Satoshi; Shigyo, Nobuhiro; Ishibashi, Kenji

    2003-01-01

    Neutron and proton nuclear data were evaluated on Zr, Nb, and W for energy up to 200 MeV. To execute optical model calculations, spherical optical potentials were developed to reproduce experimental data for many elements. The GNASH nuclear model code was used to evaluate light-particle production cross sections. For neutron emission, giant resonance correction came to be performed in the code system. (author)

  11. Study of Ne and Kr production in Mg, Al, Rb, Sr and Y targets by 0-180 MeV neutrons. Cosmochemical application

    International Nuclear Information System (INIS)

    Bertin, P.

    1989-07-01

    High sensitivity mass spectrometry technique has been used to measure production of noble gases Ne and Kr induced by 0-180 MeV neutrons in Mg, Al, Rb, Sr and Y targets. This experiment allowed us an evaluation of the implied excitation functions, in an energy range where no experimental data were available. These results have exhibited the importance of secondary neutrons induced in the interaction of cosmic rays with meteorites and moon surface [fr

  12. Light charged particle production in fast neutron-induced reactions on carbon (En=40 to 75 MeV) (II). Tritons and alpha particles

    International Nuclear Information System (INIS)

    Dufauquez, C.; Slypen, I.; Benck, S.; Meulders, J.P.; Corcalciuc, V.

    2000-01-01

    Double-differential cross sections for fast neutron-induced triton and alpha-particle production on carbon are reported at six incident neutron energies between 40 and 75 MeV. Angular distributions were measured at laboratory angles between 20 deg. and 160 deg. . Energy-differential, angle-differential and total cross sections are also reported. Experimental cross sections are compared to existing experimental data and to theoretical model calculations

  13. Response of E. coli AB2463 recA to fast neutron beams with mean energies in the range 4 to 27 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Redpath, J L [Michael Reese Hospital, Chicago, Ill. (USA)

    1978-07-01

    The radiosensitivity of E.coli AB2463 recA, given as the reciprical of the mean lethal dose, Do/sup -1/, has been shown to be the same for four fast neutron beams with widely different energy spectra. It is proposed that this organism can be used to intercompare dosimetry on fast neutron beams with mean energies in the range 4 to 25 MeV with an accuracy of +- 5%.

  14. Induction of micronuclei by irradiation with neutrons produced from 600 MeV protons

    CERN Document Server

    Diehl-Marshall, I

    1980-01-01

    Chromosome damage can be detected by the observation of micronuclei . Because its sensitivity, the micronuclei induciton in meristems of Vicia faba bean roots has been selected to determine the radiation damage produced by doses ranging from 1 to 82 cGy of neutrons. The average number of miconuclei found between 24 and 48 hours after irradiation was plotted as a funciton of dose. The RBE values, using as reference radiation 60 Co y-rays, ranged from 3.5 for a neutron dose of 82 cGy to 18 for a neutron of 1 cGy. Even higher RBE values were deduced at low doses from the evaluation of cells containing multiple micronuclei.

  15. On the Design and Test of a Neutron Collimator for Real-time Neutron Imaging in the MeV Energy Range

    International Nuclear Information System (INIS)

    Beaumont, Jonathan; Colling, Bethany; Joyce, Malcolm J.; Mellor, M.

    2013-06-01

    A neutron collimator has been designed in MCNP5 and tested for feasibility of use in imaging applications. Tungsten, polyethylene, PVC and lead have been compared as collimating materials for neutrons in the MeV energy range; tungsten is predicted to be the most successful material for a restricted volume, giving the highest signal-to-noise ratio and the best resolving power. Experimental data has been used to confirm that tungsten works effectively as a neutron collimator although some discrepancies between real and MCNP5 results were observed. A suspension of tungsten powder in polyethylene has also been tested to address the machining difficulties, mass and cost issues associated with tungsten. This material performs midway between tungsten and polyethylene for a constant volume, and more successfully than tungsten for a constant mass therefore giving this material potential as a collimation material in some scenarios. Further MCNP5 modelling has been performed by varying model parameters and monitoring the collimator functions produced by these changes. These results are conclusive but dependent on the applications of the imaging system. (authors)

  16. Measurement of cross sections producing short-lived nuclei by 14 MeV neutron. Br, Te, Dy, Ho, Yb

    Energy Technology Data Exchange (ETDEWEB)

    Sakane, H.; Matsumoto, T.; Yamamoto, H.; Kawade, K. [Nagoya Univ. (Japan); Iida, T.; Takahashi, A.

    1997-03-01

    Nine neutron activation cross sections producing the nuclei with half-lives between 2 min and 57 min have been measured at energy range between 13.4 and 14.9 MeV for Br, Te, Dy, Ho, Yb. The cross sections of {sup 81}Br(n,p){sup 81m}Se, {sup 128}Te(n,p){sup 128m}Sb, {sup 128}Te(n,{alpha}){sup 125m}Sn, {sup 164}Dy(n,p){sup 164}Tb, {sup 165}Ho(n,{alpha}){sup 162}Tb, {sup 176}Yb(n,p){sup 176}Tm were newly obtained at the six energy points between 13.4-14.9 MeV, although the previous results have been obtained at one energy point. {sup 79}Br(n,2n){sup 78}Br, {sup 164}Dy(n,p){sup 164}Tb are compared with evaluated data of JENDL-3.2. The evaluations for these reactions agree reasonably well with experimental results. The cross sections of (n,p) reaction are compared with systematics by Kasugai et. al. The systematics agrees with experimental results. (author)

  17. Differential cross sections for gamma-ray production by 14 MeV neutrons with several elements in structural materials

    International Nuclear Information System (INIS)

    Murata, Isao; Yamamoto, Junji; Takahashi, Akito

    1988-01-01

    Energy differential cross sections for the gamma-rays produced from the (n,xγ) reactions by 14 MeV neutrons were measured in the gamma-ray energy range from 700 keV to 10 MeV using an NaI spectrometer. Results were obtained for the 8 natural elements; C, Al, Si, Cr, Fe, Ni, Cu and Mo. For prominent discrete gamma-rays in the differential cross sections, the production cross sections were determined by measuring angular distributions with a Ge detector. The gamma-ray energy covered the range between 500 and 3000 keV. The energy distributions have been compared with the differential cross sections evaluated in the nuclear data files of JENDL-3T, ENDL and ENDF/B-IV. The evaluations in JENDL-3T agreed fairly well with the measurements concerning the continuum energy spectra for secondary photons. Discrepancies appeared, however, for Si, Cr and Ni at the energies where the discrete gamma-rays were dominant. The ENDL evaluations were largely deviated from the experimental data. The production cross sections for the discrete gamma-rays in ENDL and ENDF/B-IV were available for the comparison with some of the measured cross sections. Results are presented for C, Al and Si. (author)

  18. Small-angle neutron polarization for the 2H(d vector,n vector)3He reaction near Esub(d) = 8MeV

    International Nuclear Information System (INIS)

    Tornow, W.; Woye, W.; Mack, G.

    1981-01-01

    Considerable improvement in the quality of analyzing power experiments performed with polarized fast neutrons has been achieved during the last few years by using neutrons from the polarization transfer reaction 2 H(d vector,n vector) 3 He at a reaction angle of theta = 0 0 . To compromise in these experiments between intensity problems and finite geometry corrections, it is desirable in some instances to subtend a full-width angle Δtheta of 20 0 (lab) centered about theta = 0 0 . In order to investigate the suitability of this reaction as a source of polarized neutrons for cases where the scatterer is close to the neutron source, the neutron polarization of the reaction 2 H(d vector,n vector) 3 He has been studied with Δtheta of about 3 0 in 3 0 steps out to theta = 20 0 (lab). An incident deuteron energy near 8 MeV was chosen to yield outgoing neutrons at 11.0 MeV, a typical energy for neutron analyzing power experiments. It is found that the effective neutron polarization, a combination of the two polarizations measured when the direction of the deuteron polarization is inverted or flipped at the polarized ion source, is large and nearly constant for angles between theta = 0 0 and theta = 10 0 (lab). (orig.)

  19. Neutron cross-sections above 20 MeV for design and modeling of ...

    Indian Academy of Sciences (India)

    One of the outstanding new developments in the field of partitioning and transmutation (P&T) concerns accelerator-driven systems (ADS) which consist of a combination of a high-power, high-energy accelerator, a spallation target for neutron production and a sub-critical reactor core. The development of the commercial ...

  20. 14 MeV fast neutron activation analysis in the year 2000

    International Nuclear Information System (INIS)

    James, W.D.

    2000-01-01

    In recent years there is a decided upswing in interest in the application of fast neutron activation analysis methodologies to certain problems, i.e., detection of contraband substances, use of steady-state and pulsing instruments of body compositions etc. The value of a method which can characterize major and minor elements in large samples is again recognized. (author)