WorldWideScience

Sample records for mev electron moving

  1. Numerical simulation on range of high-energy electron moving in accelerator target

    International Nuclear Information System (INIS)

    Shao Wencheng; Sun Punan; Dai Wenjiang

    2008-01-01

    In order to determine the range of high-energy electron moving in accelerator target, the range of electron with the energy range of 1 to 100 MeV moving in common target material of accelerator was calculated by Monte-Carlo method. Comparison between the calculated result and the published data were performed. The results of Monte-Carlo calculation are in good agreement with the published data. Empirical formulas were obtained for the range of high-energy electron with the energy range of 1 to 100 MeV in common target material by curve fitting, offering a series of referenced data for the design of targets in electron accelerator. (authors)

  2. A direct electron detector for time-resolved MeV electron microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Vecchione, T.; Denes, P.; Jobe, R. K.; Johnson, I. J.; Joseph, J. M.; Li, R. K.; Perazzo, A.; Shen, X.; Wang, X. J.; Weathersby, S. P.; Yang, J.; Zhang, D.

    2017-03-01

    The introduction of direct electron detectors enabled the structural biology revolution of cryogenic electron microscopy. Direct electron detectors are now expected to have a similarly dramatic impact on time-resolved MeV electron microscopy, particularly by enabling both spatial and temporal jitter correction. Here we report on the commissioning of a direct electron detector for time-resolved MeV electron microscopy. The direct electron detector demonstrated MeV single electron sensitivity and is capable of recording megapixel images at 180 Hz. The detector has a 15-bit dynamic range, better than 30-μmμm spatial resolution and less than 20 analogue-to-digital converter count RMS pixel noise. The unique capabilities of the direct electron detector and the data analysis required to take advantage of these capabilities are presented. The technical challenges associated with generating and processing large amounts of data are also discussed.

  3. Upper limit on the inner radiation belt MeV electron intensity

    Science.gov (United States)

    Li, X; Selesnick, RS; Baker, DN; Jaynes, AN; Kanekal, SG; Schiller, Q; Blum, L; Fennell, J; Blake, JB

    2015-01-01

    No instruments in the inner radiation belt are immune from the unforgiving penetration of the highly energetic protons (tens of MeV to GeV). The inner belt proton flux level, however, is relatively stable; thus, for any given instrument, the proton contamination often leads to a certain background noise. Measurements from the Relativistic Electron and Proton Telescope integrated little experiment on board Colorado Student Space Weather Experiment CubeSat, in a low Earth orbit, clearly demonstrate that there exist sub-MeV electrons in the inner belt because their flux level is orders of magnitude higher than the background, while higher-energy electron (>1.6 MeV) measurements cannot be distinguished from the background. Detailed analysis of high-quality measurements from the Relativistic Electron and Proton Telescope on board Van Allen Probes, in a geo-transfer-like orbit, provides, for the first time, quantified upper limits on MeV electron fluxes in various energy ranges in the inner belt. These upper limits are rather different from flux levels in the AE8 and AE9 models, which were developed based on older data sources. For 1.7, 2.5, and 3.3 MeV electrons, the upper limits are about 1 order of magnitude lower than predicted model fluxes. The implication of this difference is profound in that unless there are extreme solar wind conditions, which have not happened yet since the launch of Van Allen Probes, significant enhancements of MeV electrons do not occur in the inner belt even though such enhancements are commonly seen in the outer belt. Key Points Quantified upper limit of MeV electrons in the inner belt Actual MeV electron intensity likely much lower than the upper limit More detailed understanding of relativistic electrons in the magnetosphere PMID:26167446

  4. Investigation of transversal nuclear excitation in 208Pb at excitation energies between 6 MeV and 8 MeV using inelastic electron scattering

    International Nuclear Information System (INIS)

    Frey, R.W.

    1978-01-01

    Using high resolution inelastic electron scattering magnitic dipole and quadrupole excitations in 208 Pb were investigated in the energy range between 6 MeV and 8 MeV. The electron energy was 50 MeV and 63.5 MeV. With a mean absolute energy resolution of 33 kev. 44 excited states were found in the above energy range. The measured angular distributions were compared with DWBA-calculations using random phase approximated wave functions. (FKS)

  5. Optimisation of 12 MeV electron beam simulation using variance reduction technique

    International Nuclear Information System (INIS)

    Jayamani, J; Aziz, M Z Abdul; Termizi, N A S Mohd; Kamarulzaman, F N Mohd

    2017-01-01

    Monte Carlo (MC) simulation for electron beam radiotherapy consumes a long computation time. An algorithm called variance reduction technique (VRT) in MC was implemented to speed up this duration. This work focused on optimisation of VRT parameter which refers to electron range rejection and particle history. EGSnrc MC source code was used to simulate (BEAMnrc code) and validate (DOSXYZnrc code) the Siemens Primus linear accelerator model with the non-VRT parameter. The validated MC model simulation was repeated by applying VRT parameter (electron range rejection) that controlled by global electron cut-off energy 1,2 and 5 MeV using 20 × 10 7 particle history. 5 MeV range rejection generated the fastest MC simulation with 50% reduction in computation time compared to non-VRT simulation. Thus, 5 MeV electron range rejection utilized in particle history analysis ranged from 7.5 × 10 7 to 20 × 10 7 . In this study, 5 MeV electron cut-off with 10 × 10 7 particle history, the simulation was four times faster than non-VRT calculation with 1% deviation. Proper understanding and use of VRT can significantly reduce MC electron beam calculation duration at the same time preserving its accuracy. (paper)

  6. Number transmission of 0.6 and 0.8MeV electrons in elemental materials

    International Nuclear Information System (INIS)

    Harami, Taikan; Takagaki, Torao; Matsuda, Koji; Nakai, Yohta.

    1975-01-01

    The number transmissions of electrons in Be, Al, Cu and Ag were obtained experimentally for well collimated electron beams of 0.6 and 0.8 MeV. Experimental results of the present work join smoothly to the previous ones of 1.0 MeV to 2.0 MeV electrons. The ratios of extrapolated range Rsub(ex) to true range R 0 give generally minimum values near 1 MeV (approximately 2mc 2 ) as well as the stopping power. An investigation was done for empirical equation of the form eta=exp(-xP/CEsup(m)), where E is the incident electron energy, x, penetration depth, and p, C and m are the parameters determined from experimental data. (author)

  7. Crosslinking of commercial polyethylenes by 10 MeV electrons

    International Nuclear Information System (INIS)

    Singh, A.; Lopata, V.J.; Kremers, W.; Sze, Yu-keung

    1995-08-01

    Commercial polyethylenes were irradiated with 10 MeV electrons to induce crosslinking. The gel fraction data measured as a function of total dose suggests that crosslinking proceeds on irradiation, as expected. A number of the properties of the irradiated polyethylenes, such as the degree of oxidation, crystallinity and thermal degradation, were studied by Fourier transform infrared/photo acoustic spectroscopy, X-ray diffraction, and a pyrolysis technique coupled with gas chromatography and mass spectrometry. The results of this study suggest that commercial polyethylenes can be crosslinked to a gel fraction of ∼70%, required for wire and cable applications, by 10 MeV electrons. (author). 35 refs., 6 figs

  8. The KAERI 10 MeV Electron Linac - Description and Operational Manual

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Byung Cheol; Park, Seong Hee; Jung, Young Uk; Han, Young Hwan; Kang, Hee Young

    2005-06-15

    The objective of this technical report is to guide the right operation and maintenance of the KAERI electron linac system. The KAERI electron linac system consists of 2 MeV injector based on 176 MHz Normal conducting RF (Radio Frequency)cavity and 10 MeV main accelerator based on 352 MHz Superconducting RF cavity, electron beamlines (injection and extraction). Since a electron accelerator generates hazard radiation, this system is located at the shielded room in basement and we can operate the system using the remote control system. It includes the description and the operational manual as well as the detailed technical direction for trouble shooting.

  9. The KAERI 10 MeV Electron Linac - Description and Operational Manual

    International Nuclear Information System (INIS)

    Lee, Byung Cheol; Park, Seong Hee; Jung, Young Uk; Han, Young Hwan; Kang, Hee Young

    2005-06-01

    The objective of this technical report is to guide the right operation and maintenance of the KAERI electron linac system. The KAERI electron linac system consists of 2 MeV injector based on 176 MHz Normal conducting RF (Radio Frequency)cavity and 10 MeV main accelerator based on 352 MHz Superconducting RF cavity, electron beamlines (injection and extraction). Since a electron accelerator generates hazard radiation, this system is located at the shielded room in basement and we can operate the system using the remote control system. It includes the description and the operational manual as well as the detailed technical direction for trouble shooting

  10. Construction of 100 MeV electron linac in Kyoto University

    International Nuclear Information System (INIS)

    Shirai, Toshiyuki; Sugimura, Takeshi; Kando, Masaki

    1995-01-01

    An electron linear accelerator and a compact storage ring have been constructed at Kyoto University. The beam energy of the storage ring is 300 MeV and will be utilized as a synchrotron radiation source. The output beam energy of the linac is 100 MeV and the designed beam current is 100 mA at the pulse width of 1 μsec. The construction of the linac had been finished and the test is under going. The electron beam of 300 mA is extracted from the electron gun and the peak RF power of 20 MW is successfully fed to the accelerating structures at the pulse width of 2 μsec. (author)

  11. A sub-picosecond pulsed 5 MeV electron beam system

    International Nuclear Information System (INIS)

    Farrell, J. Paul; Batchelor, K.; Meshkovsky, I.; Pavlishin, I.; Lekomtsev, V.; Dyublov, A.; Inochkin, M.; Srinivasan-Rao, T.

    2001-01-01

    Laser excited pulsed, electron beam systems that operate at energies from 1 MeV up to 5 MeV and pulse width from 0.1 to 100 ps are described. The systems consist of a high voltage pulser and a coaxial laser triggered gas or liquid spark gap. The spark gap discharges into a pulse forming line designed to produce and maintain a flat voltage pulse for 1 ns duration on the cathode of a photodiode. A synchronized laser is used to illuminate the photocathode with a laser pulse to produce an electron beam with very high brightness, short duration, and current at or near the space charge limit. Operation of the system is described and preliminary test measurements of voltages, synchronization, and jitter are presented for a 5 MeV system. Applications in chemistry, and accelerator research are briefly discussed

  12. High-dose MeV electron irradiation of Si-SiO2 structures implanted with high doses Si+

    Science.gov (United States)

    Kaschieva, S.; Angelov, Ch; Dmitriev, S. N.

    2018-03-01

    The influence was studied of 22-MeV electron irradiation on Si-SiO2 structures implanted with high-fluence Si+ ions. Our earlier works demonstrated that Si redistribution is observed in Si+-ion-implanted Si-SiO2 structures (after MeV electron irradiation) only in the case when ion implantation is carried out with a higher fluence (1016 cm-2). We focused our attention on the interaction of high-dose MeV electron irradiation (6.0×1016 cm-2) with n-Si-SiO2 structures implanted with Si+ ions (fluence 5.4×1016 cm-2 of the same order magnitude). The redistribution of both oxygen and silicon atoms in the implanted Si-SiO2 samples after MeV electron irradiation was studied by Rutherford back-scattering (RBS) spectroscopy in combination with a channeling technique (RBS/C). Our results demonstrated that the redistribution of oxygen and silicon atoms in the implanted samples reaches saturation after these high doses of MeV electron irradiation. The transformation of amorphous SiO2 surface into crystalline Si nanostructures (after MeV electron irradiation) was evidenced by atomic force microscopy (AFM). Silicon nanocrystals are formed on the SiO2 surface after MeV electron irradiation. The shape and number of the Si nanocrystals on the SiO2 surface depend on the MeV electron irradiation, while their size increases with the dose. The mean Si nanocrystals height is 16-20 nm after irradiation with MeV electrons at the dose of 6.0×1016 cm-2.

  13. Calorimetry for absorbed dose measurement at 1-4 MeV electron accelerators

    International Nuclear Information System (INIS)

    Miller, A.

    2000-01-01

    Calorimeters are used for dose measurement, calibration and intercomparisons at industrial electron accelerators, and their use at 10 MeV electron accelerators is well documented. The work under this research agreement concerns development of calorimeters for use at electron accelerators with energies in the range of 2-4 MeV. The dose range of the calorimeters is 3-40 kGy, and their temperature stability after irradiation was found to be sufficient for practical use in an industrial environment. Measurement uncertainties were determined to be 5% at k = 2. (author)

  14. 50 MeV Run of the IOTA / FAST Electron Accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Edstrom Jr., D.; et al.

    2017-02-02

    The low-energy section of the photoinjector-based electron linear accelerator at the Fermilab Accelerator Science & Technology (FAST) facility was recently commissioned to an energy of 50 MeV. This linear accelerator relies primarily upon pulsed SRF acceleration and an optional bunch compressor to produce a stable beam within a large operational regime in terms of bunch charge, total average charge, bunch length, and beam energy. Various instrumentation was used to characterize fundamental properties of the electron beam including the intensity, stability, emittance, and bunch length. While much of this instrumentation was commissioned in a 20 MeV running period prior, some (including a new Martin- Puplett interferometer) was in development or pending installation at that time. All instrumentation has since been recommissioned over the wide operational range of beam energies up to 50 MeV, intensities up to 4 nC/pulse, and bunch structures from ~1 ps to more than 50 ps in length.

  15. A technique for determining electron losses for a 20 MeV microtron

    International Nuclear Information System (INIS)

    Harisha, P.; Nayak, A.R.; Mehta, S.K.; Soni, H.C.; Siddappa, K.

    1999-01-01

    A 22 orbit, 20 MeV electron microtron is used as a preaccelerator for the 700 MeV booster synchrotron at INDUS-1, CAT, Indore. Estimation of electron losses at the RF cavity from each orbit is important in obtaining the radiation doses from the body of the microtron. Radiation mapping of the microtron can be used to estimate these loss terms as an alternate to actual measurement by using a measuring probe. (author)

  16. The 600 MeV Saclay electron linac: 40000 hour operation

    International Nuclear Information System (INIS)

    Netter, F.

    1977-01-01

    After 40000 hours of operation, the 600 MeV Saclay's electron linac (ALS) does appear as an efficient and versatile tool, for high resolution work (20 μA in ΔE = 40 keV at E = 200MeV), for high power pion production (300 μA in 20 μs pulses at 1000 Hz and 400 MeV or 240 μA in 4 μs pulses at 3000 Hz and 390 MeV), for highly reliable positron beams acceleration, a.s.o. Main improvements made in the recent years are described in particular the automatic beam switching between any two ways among the beam handling system; and the computer newly installed in the control room with a powerful visual display allowing an easy and flexible dialogue of the operators with the computer [fr

  17. Thermoluminescence response of Ge-, Al- and Nd- doped optical fibers by 6 MeV - electron and 6 MeV - photon irradiations

    International Nuclear Information System (INIS)

    Hossain, I.; Moburak, A. A.; Saeed, M.A.; Wagiran, H.; Hida, N.; Yaakob, H.N.

    2015-01-01

    In this paper, we report the prediction of thermoluminescence responses of Neodymium-doped SiO 2 optical fibre with various dose ranges from 0.5 Gy to 4.0 Gy by 6 MeV - electron irradiations without requirement for experimental measurements. A technique has been developed to calculate prediction of 6 MeV - electron response of Neodymium-doped SiO 2 optical fibre by observing the measured TL response of 6 MV - photon and the ratio of known measured photon/electron yield ratio distribution for Ge-doped, Al-doped optical fibre and standard TLD 100 dosimeter. The samples were kept in gelatin capsule an irradiated with 6 MV - photon at the dose range from 0.5 Gy to 4.0 Gy. Siemens model Primus 3368 linear accelerator located at Hospital Sultan Ismail, Johor Bahru has been used to deliver the photon beam to the samples. We found the average response ratio of 6 MV - photon and 6 MeV - electron in Ge-doped, Al-doped optical fibre and standard TLD-100 dosimeter are 0.83(3). Observing the measured value of 6 MV - photon irradiation this average ratio is useful to find the prediction of thermoluminescence responses by 6 MeV - electron irradiation of Neodymium-doped SiO 2 optical fibre by the requirement for experimental measurements with various dose ranges from 0.5 Gy to 4.0 Gy by 6 MV - photon irradiations.

  18. Energy monitoring device for 1.5-2.4 MeV electron beams

    Energy Technology Data Exchange (ETDEWEB)

    Fuochi, P.G., E-mail: fuochi@isof.cnr.i [CNR-ISOF, Via P. Gobetti 101, I-40129 Bologna (Italy); Lavalle, M.; Martelli, A. [CNR-ISOF, Via P. Gobetti 101, I-40129 Bologna (Italy); Kovacs, A. [Institute of Isotopes, HAS, P.O.Box 77, H-1525 Budapest (Hungary); Mehta, K. [Arbeiterstrandbad Strasse 72, Vienna, A-1210 (Austria); Kuntz, F.; Plumeri, S. [Aerial, Parc d' Innovation Rue Laurent Fries F-67400 Illkirch (France)

    2010-03-11

    An easy-to-use and robust energy monitoring device has been developed for reliable detection of day-to-day small variations in the electron beam energy, a critical parameter for quality control and quality assurance in industrial radiation processing. It has potential for using on-line, thus providing real-time information. Its working principle is based on the measurement of currents, or charges, collected by two aluminium absorbers of specific thicknesses (dependent on the beam energy), insulated from each other and positioned within a faraday cup-style aluminium cage connected to the ground. The device has been extensively tested in the energy range of 4-12 MeV under standard laboratory conditions at Institute of Isotopes and CNR-ISOF using different types of electron accelerators; namely, a TESLA LPR-4 LINAC (3-6 MeV) and a L-band Vickers LINAC (7-12 MeV), respectively. This device has been also tested in high power electron beam radiation processing facilities, one equipped with a 7-MeV LUE-8 linear accelerator used for crosslinking of cables and medical device sterilization, and the other equipped with a 10 MeV Rhodotron TT100 recirculating accelerator used for in-house sterilization of medical devices. In the present work, we have extended the application of this method to still lower energy region, i.e. from 1.5 to 2.4 MeV. Also, we show that such a device is capable of detecting deviation in the beam energy as small as 40 keV.

  19. Energy monitoring device for 1.5-2.4 MeV electron beams

    Science.gov (United States)

    Fuochi, P. G.; Lavalle, M.; Martelli, A.; Kovács, A.; Mehta, K.; Kuntz, F.; Plumeri, S.

    2010-03-01

    An easy-to-use and robust energy monitoring device has been developed for reliable detection of day-to-day small variations in the electron beam energy, a critical parameter for quality control and quality assurance in industrial radiation processing. It has potential for using on-line, thus providing real-time information. Its working principle is based on the measurement of currents, or charges, collected by two aluminium absorbers of specific thicknesses (dependent on the beam energy), insulated from each other and positioned within a faraday cup-style aluminium cage connected to the ground. The device has been extensively tested in the energy range of 4-12 MeV under standard laboratory conditions at Institute of Isotopes and CNR-ISOF using different types of electron accelerators; namely, a TESLA LPR-4 LINAC (3-6 MeV) and a L-band Vickers LINAC (7-12 MeV), respectively. This device has been also tested in high power electron beam radiation processing facilities, one equipped with a 7-MeV LUE-8 linear accelerator used for crosslinking of cables and medical device sterilization, and the other equipped with a 10 MeV Rhodotron TT100 recirculating accelerator used for in-house sterilization of medical devices. In the present work, we have extended the application of this method to still lower energy region, i.e. from 1.5 to 2.4 MeV. Also, we show that such a device is capable of detecting deviation in the beam energy as small as 40 keV.

  20. The drive system of 100 MeV electron linear accelerator

    International Nuclear Information System (INIS)

    Sun Yuzhen; Su Guoping; Wang Xiulong; Tianlu

    1988-06-01

    The principle, structure, measurement results and technical performances of microwave drive system for 100MeV electron linear accelerator are presented. In this system the peak power of 15 kW is produced by the S bank middle power klystron. The output power of the klystron is divided into six subdrive lines that drive six high power klystrons respectively. The results show the system with simple structure and good characteristics completely meets the requirements of 100 MeV Linac

  1. Characterization of 2 MeV, 4 MeV, 6 MeV and 18 MeV buildup caps for use with a 0.6 cubic centimeter thimble ionization chamber

    International Nuclear Information System (INIS)

    Salyer, R.L.; VanDenburg, J.W.; Prinja, A.K.; Kirby, T.; Busch, R.; Hong-Nian Jow

    1996-07-01

    The purpose of this research is to characterize existing 2 MeV, 4 MeV and 6 MeV buildup caps, and to determine if a buildup cap can be made for the 0.6 cm 3 thimble ionization chamber that will accurately measure exposures in a high-energy photon radiation field. Two different radiation transport codes were used to computationally characterize existing 2 MeV, 4 MeV, and 6 MeV buildup caps for a 0.6 cm 3 active volume thimble ionization chamber: ITS, The Integrated TIGER Series of Coupled Electron-Photon Monte Carlo Transport Codes; and CEPXS/ONEDANT, A One-Dimensional Coupled Electron-Photon Discrete Ordinates Code Package. These codes were also used to determine the design characteristics of a buildup cap for use in the 18 MeV photon beam produced by the 14 TW pulsed power HERMES-III electron accelerator. The maximum range of the secondary electron, the depth at which maximum dose occurs, and the point where dose and collision kerma are equal have been determined to establish the validity of electronic equilibrium. The ionization chamber with the appropriate buildup cap was then subjected to a 4 MeV and a 6 MeV bremmstrahlung radiation spectrum to determine the detector response

  2. RBE comparison between rapid electrons of 20 MeV and 45 MeV with survival rate, DNA synthesis, DNA reparation and nucleoid sedimentation

    International Nuclear Information System (INIS)

    Alth, G.; Weniger, P.; Turtzer, K.; Klein, W.; Kocsis, F.; Krankenhaus der Stadt Wien-Lainz; Oesterreichisches Forschungszentrum Seibersdorf G.m.b.H. Inst. fuer Biologie)

    1982-01-01

    In order to find out possible differences of the biologic efficacy of rapid electrons of different energies, the authors examined the influence of rapid electrons of 20 MeV and 45 MeV upon the survival rate of Hela cells S3, their cell growth, DNA synthesis, DNA reparation, and sedimentation of nucleoids. The results show a difference only for the nucleoid sedimentation, i.e. there are more fractured DNA cords after 45 MeV irradiation. No significant differences could be demonstrated for the parameters of the survival curve, DNA synthesis and DNA reparation. Four double tests were carried out corresponding to the indicated types of examination. (orig.) [de

  3. Evaluation of induced radioactivity in 10 MeV electron-irradiated spices

    Energy Technology Data Exchange (ETDEWEB)

    Furuta, Masakazu; Ito, Norio; Mizohata, Akira; Matsunami, Tadao; Katayama, Tadashi; Toratani, Hirokazu (Osaka Prefectural Univ., Sakai (Japan). Research Inst. for Advanced Science and Technology); Takeda, Atsuhiko

    1993-10-01

    In order to make clear appreciation to induced radioactivity in the irradiated foods, photonuclear reactions which could produce radioactivity at energies up to 10 MeV were listed up from elemental compositions of black pepper, white pepper, red pepper, ginger and turmeric. The samples were irradiated with 10 MeV electron from a linear accelerator to a dose of 100 kGy and radioactivity was measured. Induced radioactivity could not be detected significantly by gamma-ray spectrometry and beta-ray counting in the irradiated samples except for spiked samples which contain some photonuclear target nuclides in the list. From the amount of observed radioactivities of short-lived photonuclear products in the spiked samples and calculation of H[sub 50] according to ICRP Publication 30, it was concluded that the induced radioactivity and its biological effects in the 10 MeV electron-irradiated natural samples were negligible in comparison with natural radioactivity from [sup 40]K contained in the samples. (J.P.N.).

  4. Shielding calculations for industrial 5/7.5MeV electron accelerators using the MCNP Monte Carlo Code

    Science.gov (United States)

    Peri, Eyal; Orion, Itzhak

    2017-09-01

    High energy X-rays from accelerators are used to irradiate food ingredients to prevent growth and development of unwanted biological organisms in food, and by that extend the shelf life of the products. The production of X-rays is done by accelerating 5 MeV electrons and bombarding them into a heavy target (high Z). Since 2004, the FDA has approved using 7.5 MeV energy, providing higher production rates with lower treatments costs. In this study we calculated all the essential data needed for a straightforward concrete shielding design of typical food accelerator rooms. The following evaluation is done using the MCNP Monte Carlo code system: (1) Angular dependence (0-180°) of photon dose rate for 5 MeV and 7.5 MeV electron beams bombarding iron, aluminum, gold, tantalum, and tungsten targets. (2) Angular dependence (0-180°) spectral distribution simulations of bremsstrahlung for gold, tantalum, and tungsten bombarded by 5 MeV and 7.5 MeV electron beams. (3) Concrete attenuation calculations in several photon emission angles for the 5 MeV and 7.5 MeV electron beams bombarding a tantalum target. Based on the simulation, we calculated the expected increase in dose rate for facilities intending to increase the energy from 5 MeV to 7.5 MeV, and the concrete width needed to be added in order to keep the existing dose rate unchanged.

  5. Out-of-ecliptic quiet time MeV electron increases: Ulysses COSPIN/KET observations

    International Nuclear Information System (INIS)

    Heber, B.; Ferreira, S.E.S.; Potgieter, M.S.; Henize, V.K.; Moeketsi, D.M.; Fichtner, H.; Kissmann, R.

    2004-01-01

    The propagation of cosmic rays in turbulent magnetic fields can be studied in detail by way of in-situ measurements of energetic particles in the three-dimensional heliosphere. Measurements of 3-20 MeV electrons from 1990 to 2003 have been made by the Kiel Electron Telescope (KET) onboard the Ulysses spacecraft during varying solar conditions. In order to interpret these measurements, it is necessary to distinguish between solar, galactic and Jovian electrons and to investigate their propagation, by using sophisticated particle propagation models. The solar contribution to the MeV electron intensities can be excluded by analyzing the electron energy spectra and the nuclei time histories. The residual electron intensities can be reasonably described by modulation models taking into account galactic cosmic rays as well as Jovian electrons using different diffusion coefficients for solar minimum and maximum. The way in which the relative contribution of Jovian (point source in the ecliptic) and galactic electrons (isotropic source) varies along the Ulysses orbit is strongly dependent on the choice of these coefficients. Since the 1970's quiet time electron increases have been observed in the ecliptic and interpreted as Jovian electron increases. Therefore, the occurrence of such quiet time electron increases is an indicator for a dominant Jovian contribution to the measured MeV electron intensities. At solar minimum and maximum such events have been observed up to ∼30 deg. and ∼45 deg. These observations are crucial for a determination of the diffusion parameters. At solar maximum a more efficient latitude transport is needed to account for the electron intensity variations

  6. Beam dynamics study of a 30 MeV electron linear accelerator to drive a neutron source

    Science.gov (United States)

    Kumar, Sandeep; Yang, Haeryong; Kang, Heung-Sik

    2014-02-01

    An experimental neutron facility based on 32 MeV/18.47 kW electron linac has been studied by means of PARMELA simulation code. Beam dynamics study for a traveling wave constant gradient electron accelerator is carried out to reach the preferential operation parameters (E = 30 MeV, P = 18 kW, dE/E E-gun, pre-buncher, buncher, and 2 accelerating columns. A disk-loaded, on-axis-coupled, 2π/3-mode type accelerating rf cavity is considered for this linac. After numerous optimizations of linac parameters, 32 MeV beam energy is obtained at the end of the linac. As high electron energy is required to produce acceptable neutron flux. The final neutron flux is estimated to be 5 × 1011 n/cm2/s/mA. Future development will be the real design of a 30 MeV electron linac based on S band traveling wave.

  7. Ultrafast electron diffraction with megahertz MeV electron pulses from a superconducting radio-frequency photoinjector

    Energy Technology Data Exchange (ETDEWEB)

    Feng, L. W.; Lin, L.; Huang, S. L.; Quan, S. W.; Hao, J. K.; Zhu, F.; Wang, F.; Liu, K. X., E-mail: kxliu@pku.edu.cn [Institute of Heavy Ion Physics and State Key Laboratory of Nuclear Physics and Technology, Peking University, Beijing 100871 (China); Jiang, T.; Zhu, P. F.; Fu, F.; Wang, R.; Zhao, L.; Xiang, D., E-mail: dxiang@sjtu.edu.cn [Key Laboratory for Laser Plasmas (Ministry of Education), Department of Physics and Astronomy, Shanghai Jiao Tong University, Shanghai 200240 (China); IFSA Collaborative Innovation Center, Shanghai Jiao Tong University, Shanghai 200240 (China)

    2015-11-30

    We report ultrafast relativistic electron diffraction operating at the megahertz repetition rate where the electron beam is produced in a superconducting radio-frequency (rf) photoinjector. We show that the beam quality is sufficiently high to provide clear diffraction patterns from gold and aluminium samples. With the number of electrons, several orders of magnitude higher than that from a normal conducting photocathode rf gun, such high repetition rate ultrafast MeV electron diffraction may open up many new opportunities in ultrafast science.

  8. Color centers of a borosilicate glass induced by 10 MeV proton, 1.85 MeV electron and 60Co-γ ray

    Science.gov (United States)

    Du, Jishi; Wu, Jiehua; Zhao, Lili; Song, Lixin

    2013-05-01

    Optical absorption spectra, electron paramagnetic resonance (EPR) spectra, Raman spectra of a borosilicate glass after irradiation by 10 MeV proton, 1.85 MeV electron and 60Co-γ ray were studied. The process of irradiation inducing color centers in the glass was discussed. The band gap of the glass before and after 60Co-γ ray irradiation was studied using Mott and Davis's theory, and it was found that calculated change of the band gap introduced a paradox, because Mott and Davis's theory on the band gap cannot be adopted in the study on the irradiated glass.

  9. 10 MeV RF electron linac for industrial applications

    International Nuclear Information System (INIS)

    2017-01-01

    Electron linacs have found numerous applications in the field of radiation processing on an industrial scale. High power RF electron linacs are commonly used for food irradiation, medical sterilization, cross-linking of polymers, etc. For this purpose, the 10 MeV RF linac has been indigenously designed, developed, commissioned and is being used regularly at 3 kW beam power. This paper gives a brief description of the linac and its utilization for various applications. Safety considerations and regulatory aspects of the linac are also discussed

  10. Direct determination of k Q factors for cylindrical and plane-parallel ionization chambers in high-energy electron beams from 6 MeV to 20 MeV

    Science.gov (United States)

    Krauss, A.; Kapsch, R.-P.

    2018-02-01

    For the ionometric determination of the absorbed dose to water, D w, in high-energy electron beams from a clinical accelerator, beam quality dependent correction factors, k Q, are required. By using a water calorimeter, these factors can be determined experimentally and potentially with lower standard uncertainties than those of the calculated k Q factors, which are tabulated in various dosimetry protocols. However, one of the challenges of water calorimetry in electron beams is the small measurement depths in water, together with the steep dose gradients present especially at lower energies. In this investigation, water calorimetry was implemented in electron beams to determine k Q factors for different types of cylindrical and plane-parallel ionization chambers (NE2561, NE2571, FC65-G, TM34001) in 10 cm  ×  10 cm electron beams from 6 MeV to 20 MeV (corresponding beam quality index R 50 ranging from 1.9 cm to 7.5 cm). The measurements were carried out using the linear accelerator facility of the Physikalisch-Technische Bundesanstalt. Relative standard uncertainties for the k Q factors between 0.50% for the 20 MeV beam and 0.75% for the 6 MeV beam were achieved. For electron energies above 8 MeV, general agreement was found between the relative electron energy dependencies of the k Q factors measured and those derived from the AAPM TG-51 protocol and recent Monte Carlo-based studies, as well as those from other experimental investigations. However, towards lower energies, discrepancies of up to 2.0% occurred for the k Q factors of the TM34001 and the NE2571 chamber.

  11. Direct determination of k Q factors for cylindrical and plane-parallel ionization chambers in high-energy electron beams from 6 MeV to 20 MeV.

    Science.gov (United States)

    Krauss, A; Kapsch, R-P

    2018-02-06

    For the ionometric determination of the absorbed dose to water, D w , in high-energy electron beams from a clinical accelerator, beam quality dependent correction factors, k Q , are required. By using a water calorimeter, these factors can be determined experimentally and potentially with lower standard uncertainties than those of the calculated k Q factors, which are tabulated in various dosimetry protocols. However, one of the challenges of water calorimetry in electron beams is the small measurement depths in water, together with the steep dose gradients present especially at lower energies. In this investigation, water calorimetry was implemented in electron beams to determine k Q factors for different types of cylindrical and plane-parallel ionization chambers (NE2561, NE2571, FC65-G, TM34001) in 10 cm  ×  10 cm electron beams from 6 MeV to 20 MeV (corresponding beam quality index R 50 ranging from 1.9 cm to 7.5 cm). The measurements were carried out using the linear accelerator facility of the Physikalisch-Technische Bundesanstalt. Relative standard uncertainties for the k Q factors between 0.50% for the 20 MeV beam and 0.75% for the 6 MeV beam were achieved. For electron energies above 8 MeV, general agreement was found between the relative electron energy dependencies of the k Q factors measured and those derived from the AAPM TG-51 protocol and recent Monte Carlo-based studies, as well as those from other experimental investigations. However, towards lower energies, discrepancies of up to 2.0% occurred for the k Q factors of the TM34001 and the NE2571 chamber.

  12. Electron-positron collision physics: 1 MeV to 2 TeV

    International Nuclear Information System (INIS)

    Perl, M.L.

    1988-07-01

    An overview of electron-positron collision physics is presented. It begins at 1 MeV, the energy region of positronium formation, and extends to 2 TeV, the energy region which requires an electron- positron linear collider. In addition, the concept of searching for a lepton-specific forces is discussed. 18 refs., 15 figs., 1 tab

  13. First H- beam accelerated at Linac4: 3MeV done, 157 MeV to go!

    CERN Multimedia

    Linac4 Project Team

    2013-01-01

    On 14 November, the first H- (one proton surrounded by two electrons) beam was accelerated to the energy of 3 MeV in the Linac4 - the new linear accelerator that will replace Linac2 as low-energy injector in the LHC accelerator chain.      A view of the Linac4 taken during the recent tests (top image) and the current measured by the instruments at the end of the acceleration line on 14 November (bottom image). Images: Linac4 collaboration. Using the recently installed Radio Frequency Quadrupole (RFQ) accelerator, 13 mA of current were accelerated to the energy of 3 MeV. After the successful commissioning of the Linac4 RFQ at the 3 MeV test stand completed during the first months of 2013, the whole equipment (composed of the RFQ itself, the following Medium Energy Beam Transport line and its diagnostic line) were moved to the Linac4 tunnel during summer and installed in their final position. In the meantime, a new ion source was assembled, installed and successfu...

  14. Monte-Carlo calculations of forward directed bremsstrahlung produced by 20 and 45 MeV electrons on tungsten

    International Nuclear Information System (INIS)

    Goosman, D.R.

    1983-01-01

    The SANDYL Monte-Carlo code has been used to calculate the Bremsstrahlung photon production from beams of parallel electrons incident upon three target geometries. These are 20 MeV electrons onto 1 mm of tungsten + 59 mm of Be, which simulates the operating parameters of the FXR electron accelerator at LLNL Bldg. 801, 45 MeV electrons onto 1 mm of tungsten, and finally 45 MeV electrons onto 1 mm of tungsten and 147 mm of Be. The latter two situations simulate possible future modifications to the FXR accelerator. Graphs of the spectral shape of the Bremsstrahlung photons emitted with angles between 0 0 and 1 0 to the electron direction, the angular distribution of photon-MeV, and the dose reduction curves for each of the three geometries are given. The latter dose reduction curves allow one to calculate forward-directed photon fluxes in real-life situations where the electron beam has non-zero angular divergence

  15. Physical design of 9 MeV travelling wave electron linac accelerating tube

    International Nuclear Information System (INIS)

    Chen Huaibi; Ding Xiaodong; Lin Yuzheng

    2000-01-01

    An accelerating tube is described. It is a part of an accelerator used for inspection of vehicle cargoes in rail cars, trucks, shipping containers, or airplanes in customs. A klystron with power of 4 MW and frequency of 2856 MHz will be applied to supply microwave power. The electrons can be accelerated by a travelling wave in the accelerating tube about 220 cm long, with a buncher whose capture efficiency is more than 80%. Energy of electrons after travelling through the tube can reach 9 MeV (pulse current intensity 170 mA) or 6 MeV (pulse current intensity 300 mA). Physical design of the accelerating tube, including the calculations of longitudinal particle dynamics, structure parameter and working character is carried out

  16. Design and development of 3 MeV, 30 kW DC industrial electron accelerator at Electron Beam Centre, Kharghar

    International Nuclear Information System (INIS)

    Mittal, K.C.; Nanu, K.; Jain, A.

    2006-01-01

    High power electron beam accelerators are becoming an important tool for industrial radiation process applications. Keeping this in mind, a 3 MeV, 10 mA, 30 kW DC industrial electron accelerator has been designed and is in advanced stage of development at Electron Beam Center, Kharghar, Navi Mumbai. The operating range of this accelerator is 1 MeV to 3 MeV with maximum beam current of 10 mA. Electron beam at 5 keV is generated in electron gun with LaB 6 cathode and is injected into accelerating column at a vacuum of 10 -7 torr. After acceleration the beam is scanned and taken out in air through a 100 cm X 7 cm titanium window for radiation processing applications. The high voltage accelerating power supply is based on a capacitive coupled parallel fed voltage multiplier scheme operating at 120 kHz. A 50 kW oscillator feeds power to high voltage multiplier column. The electron gun, accelerating column and high voltage multiplier column are housed in accelerator tank filled with SF 6 gas insulation at 6 kg/cm 2 . The accelerator is located in a RCC building with product conveyor for handling products. A central computerized control system is adopted for operation of the accelerator. Accelerator is in the advance stage of commissioning. Many of the subsystems have been commissioned and tested. This paper describes the design details and current status of the accelerator and various subsystems. (author)

  17. Scalability of the LEU-Modified Cintichem Process: 3-MeV Van de Graaff and 35-MeV Electron Linear Accelerator Studies

    Energy Technology Data Exchange (ETDEWEB)

    Rotsch, David A. [Argonne National Lab. (ANL), Argonne, IL (United States). Nuclear Engineering Division; Brossard, Tom [Argonne National Lab. (ANL), Argonne, IL (United States). Nuclear Engineering Division; Roussin, Ethan [Argonne National Lab. (ANL), Argonne, IL (United States). Nuclear Engineering Division; Quigley, Kevin [Argonne National Lab. (ANL), Argonne, IL (United States). Nuclear Engineering Division; Chemerisov, Sergey [Argonne National Lab. (ANL), Argonne, IL (United States). Nuclear Engineering Division; Gromov, Roman [Argonne National Lab. (ANL), Argonne, IL (United States). Nuclear Engineering Division; Jonah, Charles [Argonne National Lab. (ANL), Argonne, IL (United States). Nuclear Engineering Division; Hafenrichter, Lohman [Argonne National Lab. (ANL), Argonne, IL (United States). Nuclear Engineering Division; Tkac, Peter [Argonne National Lab. (ANL), Argonne, IL (United States). Nuclear Engineering Division; Krebs, John [Argonne National Lab. (ANL), Argonne, IL (United States). Nuclear Engineering Division; Vandegrift, George F. [Argonne National Lab. (ANL), Argonne, IL (United States). Nuclear Engineering Division

    2016-10-31

    Molybdenum-99, the mother of Tc-99m, can be produced from fission of U-235 in nuclear reactors and purified from fission products by the Cintichem process, later modified for low-enriched uranium (LEU) targets. The key step in this process is the precipitation of Mo with α-benzoin oxime (ABO). The stability of this complex to radiation has been examined. Molybdenum-ABO was irradiated with 3 MeV electrons produced by a Van de Graaff generator and 35 MeV electrons produced by a 50 MeV/25 kW electron linear accelerator. Dose equivalents of 1.7–31.2 kCi of Mo-99 were administered to freshly prepared Mo-ABO. Irradiated samples of Mo-ABO were processed according to the LEU Modified-Cintichem process. The Van de Graaff data indicated good radiation stability of the Mo-ABO complex up to ~15 kCi dose equivalents of Mo-99 and nearly complete destruction at doses >24 kCi Mo-99. The linear accelerator data indicate that even at 6.2 kCi of Mo-99 equivalence of dose, the sample lost ~20% of Mo-99. The 20% loss of Mo-99 at this low dose may be attributed to thermal decomposition of the product from the heat deposited in the sample during irradiation.

  18. Imaging nanoscale spatial modulation of a relativistic electron beam with a MeV ultrafast electron microscope

    Science.gov (United States)

    Lu, Chao; Jiang, Tao; Liu, Shengguang; Wang, Rui; Zhao, Lingrong; Zhu, Pengfei; Liu, Yaqi; Xu, Jun; Yu, Dapeng; Wan, Weishi; Zhu, Yimei; Xiang, Dao; Zhang, Jie

    2018-03-01

    An accelerator-based MeV ultrafast electron microscope (MUEM) has been proposed as a promising tool to the study structural dynamics at the nanometer spatial scale and the picosecond temporal scale. Here, we report experimental tests of a prototype MUEM where high quality images with nanoscale fine structures were recorded with a pulsed ˜3 MeV picosecond electron beam. The temporal and spatial resolutions of the MUEM operating in the single-shot mode are about 4 ps (FWHM) and 100 nm (FWHM), corresponding to a temporal-spatial resolution of 4 × 10-19 s m, about 2 orders of magnitude higher than that achieved with state-of-the-art single-shot keV UEM. Using this instrument, we offer the demonstration of visualizing the nanoscale periodic spatial modulation of an electron beam, which may be converted into longitudinal density modulation through emittance exchange to enable production of high-power coherent radiation at short wavelengths. Our results mark a great step towards single-shot nanometer-resolution MUEMs and compact intense x-ray sources that may have widespread applications in many areas of science.

  19. Construction of a 1 MeV Electron Accelerator for High Precision Beta Decay Studies

    Science.gov (United States)

    Longfellow, Brenden

    2014-09-01

    Beta decay energy calibration for detectors is typically established using conversion sources. However, the calibration points from conversion sources are not evenly distributed over the beta energy spectrum and the foil backing of the conversion sources produces perturbations in the calibration spectrum. To improve this, an external, tunable electron beam coupled by a magnetic field can be used to calibrate the detector. The 1 MeV electron accelerator in development at Triangle Universities Nuclear Laboratory (TUNL) utilizes a pelletron charging system. The electron gun shoots 104 electrons per second with an energy range of 50 keV to 1 MeV and is pulsed at a 10 kHz rate with a few ns width. The magnetic field in the spectrometer is 1 T and guiding fields of 0.01 to 0.05 T for the electron gun are used to produce a range of pitch angles. This accelerator can be used to calibrate detectors evenly over its energy range and determine the detector response over a range of pitch angles. Beta decay energy calibration for detectors is typically established using conversion sources. However, the calibration points from conversion sources are not evenly distributed over the beta energy spectrum and the foil backing of the conversion sources produces perturbations in the calibration spectrum. To improve this, an external, tunable electron beam coupled by a magnetic field can be used to calibrate the detector. The 1 MeV electron accelerator in development at Triangle Universities Nuclear Laboratory (TUNL) utilizes a pelletron charging system. The electron gun shoots 104 electrons per second with an energy range of 50 keV to 1 MeV and is pulsed at a 10 kHz rate with a few ns width. The magnetic field in the spectrometer is 1 T and guiding fields of 0.01 to 0.05 T for the electron gun are used to produce a range of pitch angles. This accelerator can be used to calibrate detectors evenly over its energy range and determine the detector response over a range of pitch angles

  20. Development of polystyrene calorimeter for application at electron energies down to 1.5 MeV

    DEFF Research Database (Denmark)

    Miller, A.; Kovacs, A.; Kuntz, F.

    2002-01-01

    Polystyrene (PS) calorimeters developed at Riso National Laboratory for use below 4 MeV have been modified due to irradiation technology requirements concerning both design principles and dimensions. The temperature-time relationship after irradiation was measured, and two ways of dose measurement...... the average and the surface dose and to prove the applicability of the new low energy calorimeter for calibration purposes at 1.5 and 2 MeV electron energy. Alanine dosimeters of 2 mm thickness were used to calibrate the calorimeters and their use for nominal dose measurements was demonstrated in a series...... of intercomparisons. The use as routine dosimeters at electron accelerators operating in the energy range of 1.5-4 MeV was also demonstrated. (C) 2002 Elsevier Science Ltd. All rights reserved....

  1. POSITRON-ELECTRON DECAY OF SI-28, AT AN EXCITATION-ENERGY OF 50-MEV

    NARCIS (Netherlands)

    BUDA, A; BACELAR, JC; BALANDA, A; VANDERPLOEG, H; SUJKOWSKI, Z; VANDERWOUDE, A

    1993-01-01

    The electron-positron pair decay of Si-28 at 50 MeV excitation produced by the isospin T=0 (alpha + Mg-24) and the mixed isospin T=0,1 (He-3 + Mg-25) reactions has been studied using a special designed Positron-Electron pair spectrometer PEPSI.

  2. Secondary electron emission from 0.5--2.5-MeV protons and deuterons

    International Nuclear Information System (INIS)

    Thornton, T.A.; Anno, J.N.

    1977-01-01

    Measurement of the secondary electron currents leaving Al, V, Fe, 316 stainless steel, Nb, and Mo foils undergoing 0.5--2.5-MeV proton and deuteron bombardment were made to determine the secondary electron emission ratios for these ions. The measured secondary electron yields were of the order of 1.0, with the deuterons producing generally higher yields than the protons

  3. Interpretation of recent positron-electron measurements between 20 and 800 MeV

    International Nuclear Information System (INIS)

    Pellerin, C.J.; Hartman, R.C.

    1975-01-01

    The recent positron and negatron spectra measured by Hartman and Pellerin (see pages 402-407) are discussed with regard to the problem of solar modulation. At energies above 180 MeV, the spherically symmetric Fokker-Planck equation with a diffusion coefficient proportional to particle rigidity provides reasonable fits to both the positron and total electron data. At energies below 180 MeV the data are consistent with a continuation of the same diffusion coefficient and local source of negatrons, or a change in the diffusion coefficient to a constant value. (orig.) [de

  4. Intensity maps of MeV electrons and protons below the radiation belt

    International Nuclear Information System (INIS)

    Kohno, T.; Munakata, K.; Murakami, H.; Nakamoto, A.; Hasebe, N.; Kikuchi, J.; Doke, T.

    1988-01-01

    The global distributions of energetic electrons (0.19 - 3.2 MeV) and protons (0.64 - 35 MeV) are shown in the form of contour maps. The data were obtained by two sets of energetic particle telescopes on board the satellite OHZORA. The observed altitude range is 350 - 850 Km. Ten degress meshes in longitude and latitude were used to obtain the intensity contours. A pitch angle distribution of J(α) = J(90). sin n α with n = 5 A is assumed to get the average intensity in each mesh. (author) [pt

  5. Measurement of photon showers in lead produced by electrons of 150 MeV

    International Nuclear Information System (INIS)

    Goeringer, H.; Eyss, H.J. von; Schoch, B.

    1976-01-01

    The photon energy spectra induced by 150 MeV electrons in lead were measured in the energy range from 40 MeV up to the primary electron energy. The target thickness was varied between 0.1 and 2.5 radiation lengths X 0 . The photons were analyzed by use of a technique based on deuteron photodisintegration. Differential and integral shower spectra are presented and compared with Monte Carlo calculations of Nagel and Messel et al., both interpolated to our primary energy of 150 MeV. The measured spectra show good agreement with these Monte Carlo calculations for the thickest target of 2.5X 0 and with calculated bremsstrahlung spectra for the thinnest target of 0.1X 0 . Considerable discrepancies, however, are found for medium target thicknesses in the range 0 . Around the shower maxima, the shower spectra are narrower and the maxima are shifted about 0.3-0.4X 0 to lower target thicknesses, furthermore the number of photons at the shower maxima are up to 50% higher than calculated. (Auth.)

  6. CESAR, 2 MeV electron storage ring.

    CERN Multimedia

    CERN PhotoLab

    1967-01-01

    CESAR (CERN Electron Storage and Accumulation Ring) was built as a study-model for the ISR (Intersecting Storage Rings). The model had to be small (24 m circumference) and yet the particles had to be highly relativistic, which led to the choice of electrons. On the other hand, in order to model the behaviour of protons, effects from synchrotron radiation had to be negligible, which meant low magnetic fields (130 G in the bending magnets) and a corresponding low energy of 1.75 MeV. All the stacking (accumulation) procedures envisaged for the ISR were proven with CESAR, and critical aspects of transverse stability were explored. Very importantly, CESAR was the test-bed for the ultrahigh vacuum techniques and components, essential for the ISR, with a final pressure of 6E-11 Torr. The CESAR project was decided early in 1960, design was completed in 1961 and construction in 1963. After an experimental period from 1964 to 1967, CESAR was dismantled in 1968.

  7. Evaluation of BPW-34 photodiode answer for 10 MeV electron dosimetry

    International Nuclear Information System (INIS)

    Khoury, H.J.; Melo, F.A.; Hazin, C.A.

    1992-01-01

    The viability of commercial photodiodes used for dosimetry of high energy electron beams was studied. The measures were made in a linear accelerators of 10 MeV, using the BPW-34 photodiode. The average energy of electrons on phantom surface and their average range were determined with the photodiode, and the results were compared with the obtained with a ionization chamber of parallel plate. (C.G.C.)

  8. Microwave system of the 7-10 MeV electron linear accelerator ALIN for medical applications

    International Nuclear Information System (INIS)

    Martin, D.; Iliescu, E.; Stirbet, M.; Oproiu, C.; Vintan, I.

    1978-01-01

    A detailed description of the Central Institute of Physics 10 MeV linear microwave system and its associated subsystems are presented. Methods of impedance matching to obtain maximum power transfer are described along with broadband design methods for transmission-line impedance transformers. Experimental results for such microwave devices are included. With respect to microwave device performances, simultaneous high efficiency and high power capability with reliability and long life at relatively low unit cost have only recently been achieved as typical device characteristics. Industrial, medical and scientific application of microwave electron accelerators have markedly influenced microwave research progress. Radiographic linear accelerators have grown substantially mainly during the past few years. Following this, the improvements of microwave device performances solicit our attention. The first electron therapy Linear Accelerator ALIN 10 marks a new stage in the development of such instrumentation. Its subsequent ALIN 15 is designed to produce a maximum energy of 18 MeV to widen its applicability in radiotherapy. In addition, a new electron linear accelerator of 8 MeV for nondestructive testing has been started. (author)

  9. Bias dependent charge trapping in MOSFETs during 1 and 6 MeV electron irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Shinde, N.S. [Department of Chemical Engineering, Mie University, 5148507 (Japan); Kulkarni, V.R.; Mathakari, N.L.; Bhoraskar, V.N. [Department of Physics, Univeristy of Pune, Pune 411007 (India); Dhole, S.D. [Department of Physics, Univeristy of Pune, Pune 411007 (India)], E-mail: sanjay@physics.unipune.ernet.in

    2008-06-15

    To study irradiation-induced charge trapping in SiO{sub 2} and around the SiO{sub 2}-Si interface, depletion n-MOSFETs (metal-oxide-semiconductor field effect transistor) were used. The devices were gate biased during 1 and 6 MeV pulsed electron irradiation. The I{sub D}-V{sub DS} (drain current versus drain voltage) and I{sub D}-V{sub GS} (drain current versus gate voltage) characteristics were measured before and after irradiation. The shift in threshold voltage {delta}V{sub T} (difference in threshold voltage V{sub T} before and after irradiation) exhibited trends depending on the applied gate bias during 1 MeV electron irradiation. This behavior can be associated to the contribution of irradiation-induced negative charge {delta}N{sub IT} buildup around the SiO{sub 2}-Si interface to {delta}V{sub T}, which is sensitive to the electron tunneling from the substrates. However, only weak gate bias dependence was observed in 6 MeV electron irradiated devices. Independent of the energy loss and applied bias, the positive oxide trapped charge {delta}N{sub OT} is marginal and can be associated to thin and good quality of SiO{sub 2}. These results are explained using screening of free and acceptor states by the applied bias during irradiation, thereby reducing the total irradiation-induced charges.

  10. Accuracy evaluation of a Compton X-ray spectrometer with bremsstrahlung X-rays generated by a 6 MeV electron bunch

    Energy Technology Data Exchange (ETDEWEB)

    Kojima, Sadaoki, E-mail: kojima-s@ile.osaka-u.ac.jp; Arikawa, Yasunobu; Zhang, Zhe; Ikenouchi, Takahito; Morace, Alessio; Nagai, Takahiro; Abe, Yuki; Sakata, Shouhei; Inoue, Hiroaki; Utsugi, Masaru; Nakai, Mitsuo; Nishimura, Hiroaki; Shiraga, Hiroyuki; Fujioka, Shinsuke; Azechi, Hiroshi [Institute of Laser Engineering, Osaka University, 2-6 Yamada-oka, Suita, Osaka 565-0871 (Japan); Nishimura, Yasuhiko; Togawa, Hiromi [Toyota Technical Development Corporation, 1-21 Imae, Hanamoto-cho, Toyota, Aichi 470-0334 (Japan); Ozaki, Tetsuo [National Institute for Fusion Science, 322-6 Oroshicho, Toki, Gifu 509-5292 (Japan); Kato, Ryukou [The Institute of Science and Industrial Research, Osaka University, 2-6 Yamada-oka, Suita, Osaka (Japan)

    2014-11-15

    A Compton-scattering-based X-ray spectrometer is developed to obtain the energy distribution of fast electrons produced by intense laser and matter interactions. Bremsstrahlung X-rays generated by fast electrons in a material are used to measure fast electrons’ energy distribution in matter. In the Compton X-ray spectrometer, X-rays are converted into recoil electrons by Compton scattering in a converter made from fused silica glass, and a magnet-based electron energy analyzer is used to measure the energy distribution of the electrons that recoil in the direction of the incident X-rays. The spectrum of the incident X-rays is reconstructed from the energy distribution of the recoil electrons. The accuracy of this spectrometer is evaluated using a quasi-monoenergetic 6 MeV electron bunch that emanates from a linear accelerator. An electron bunch is injected into a 1.5 mm thick tungsten plate to produce bremsstrahlung X-rays. The spectrum of these bremsstrahlung X-rays is obtained in the range from 1 to 9 MeV. The energy of the electrons in the bunch is estimated using a Monte Carlo simulation of particle-matter interactions. The result shows that the spectrometer's energy accuracy is ±0.5 MeV for 6.0 MeV electrons.

  11. Production of iodine-123 radiobiological specimen on 25 MeV electron beam

    International Nuclear Information System (INIS)

    Oganesyan, Yu.Ts.; Starodub, G.Ya.; Buklanov, G.V.; Korotkin, Yu.S.; Belov, A.G.

    1988-01-01

    The technique is described and experimental results are presented for production of radioactive specimen-iodine-123 for medical biological investigations. It is shown that in ten hour irradiation of 124 Xe enriched target of 10 g weight by the 25 MeV electron beam at MT-25 microtron short lived 123 I with activity of about 200 mCl can be accumulated. The procedure was developed for extraction of radioactive atoms and preparing the solution that permits to obtain during 1-1.5 h after the end of irradiation the specimen which satisfies all pharmacopeia requirements. It follows from the results that using small-size electron accelerators with the beam energy up to 25 MeV permits to organize economical and large-scale production of high quality radioactive specimen of 123 I for servicing a large region of this country. 14 refs.; 4 figs.; 1 tab

  12. Positron-electron decay of 28Si at an excitation energy of 50 MeV

    International Nuclear Information System (INIS)

    Buda, A.; Bacelar, J.C.; Balanda, A.; Ploeg, H. van der; Sujkowski, Z.; Woude, A. van der

    1993-01-01

    The electron-positron pair decay of 28 Si at 50 MeV excitation produced by the isospin T=0 (α+ 24 Mg) and the mixed isospin T=0, 1 ( 3 He+ 25 Mg) reactions has been studied using a special designed Positron-Electron pair spectrometer PEPSI. (orig.)

  13. Microdosimetry of 0.5 to 2.0 MeV electron beams

    International Nuclear Information System (INIS)

    Braby, L.A.; Roesch, W.C.

    1980-08-01

    The energy imparted in microscopic volumes by electron beams with initial energies from 0.5 to 2.0 MeV has been measured at various depths in plastic. The problems associated with measuring energy deposition spectra of low LET radiations are serious, but the potential importance of these measurements in radiation biophysics justifies the effort required to obtain them. Recent results obtained by Goodhead et al. indicate an RBE greater than 2 for 0.3 keV x-rays compared to 250 kV x-rays, and our results with Chlamydomonas reinhardi indicate an RBE of 1.6 for a 1.5 MeV electron beam at a depth of 400 gm/cm 2 in lucite compared to the same beam at the surface. Development of a theory which appears to explain these results in terms of the microscopic distribution of energy deposition has motivated a detailed study of energy deposition spectra for an electron beam attenuated by various thicknesses of lucite. Simulated sites from 0.5 to 1.9 μm in diameter were studied. The values of anti y determined in these single event measurements compare favorably with those calculated from direct measurements of z reported previously. As expected, the means of the distributions increase significantly with increasing depth in an absorber

  14. 5 MeV 300 kW electron accelerator project

    International Nuclear Information System (INIS)

    Auslender, V.L.; Cheskidov, V.G.; Gornakov, I.V.

    2004-01-01

    The paper presents a project of a high power linear accelerator for industrial applications. The accelerator has a modular structure and consists of the chain of accelerating cavities connected by the axis-located coupling cavities with coupling slots in the common walls. Main parameters of the accelerator are: operating frequency of 176 MHz, electron energy of up to 5 MeV, average beam power of 300 kW. The required RF pulse power can be supplied by the TH628 diacrode

  15. Color centers of a borosilicate glass induced by 10 MeV proton, 1.85 MeV electron and 60Co-γ ray

    International Nuclear Information System (INIS)

    Du, Jishi; Wu, Jiehua; Zhao, Lili; Song, Lixin

    2013-01-01

    Optical absorption spectra, electron paramagnetic resonance (EPR) spectra, Raman spectra of a borosilicate glass after irradiation by 10 MeV proton, 1.85 MeV electron and 60 Co-γ ray were studied. The process of irradiation inducing color centers in the glass was discussed. The band gap of the glass before and after 60 Co-γ ray irradiation was studied using Mott and Davis's theory, and it was found that calculated change of the band gap introduced a paradox, because Mott and Davis's theory on the band gap cannot be adopted in the study on the irradiated glass. - Highlights: ► All the three types of irradiation induce the same types of color centers. ► Calculated change of the band gap introduced a paradox. ► Mott and Davis's theory on band gap cannot be adopted in the irradiated glass

  16. Application of clear polymethylmethacrylate dosimeter Radix W to a few MeV electron in radiation processing

    International Nuclear Information System (INIS)

    Seito, Hajime; Ichikawa, Tatsuya; Hanaya, Hiroaki; Sato, Yoshishige; Kaneko, Hirohisa; Haruyama, Yasuyuki; Watanabe, Hiroshi; Kojima, Takuji

    2009-01-01

    Characteristics of clear PMMA dosimeter (Radix W) were studied for electron irradiation and compared with the response for gamma irradiation. The dose-response curves were nearly linear up to 30 kGy and become sublinear at higher doses. The radiation-induced absorbance was reduced with 6% within 4 h after irradiation. Dose comparisons were performed for 2, 3, 4 and 5 MeV electron irradiation using cellulose triacetate dosimeter (CTA) (FTR-125) and Radix W dosimeters which were independently calibrated for 2 MeV electrons and 60 Co gamma-rays using calorimeter and ionizing chamber, respectively. The doses estimated by CTA and Radix W were different by about 20%. The magnitude of this difference was, however, independent of electron energy.

  17. MeV energy electron beam induced damage in isotactic polypropylene

    Energy Technology Data Exchange (ETDEWEB)

    Mathakari, N.L.; Bhoraskar, V.N. [Microtron Accelerator Laboratory, Department of Physics, University of Pune, Pune 411007 (India); Dhole, S.D. [Microtron Accelerator Laboratory, Department of Physics, University of Pune, Pune 411007 (India)], E-mail: sanjay@physics.unipune.ernet.in

    2008-06-15

    A few thin films of isotactic polypropylene were irradiated with 6 MeV energy electrons, in the fluence range from 5 x 10{sup 14} to 2 x 10{sup 15} electrons/cm{sup 2}. The structural, optical and mechanical properties were characterized by techniques such as FTIR, UV-vis, XRD, SEM, hardness and contact angle measurements. The FTIR spectra indicate that C-H and C-C bonds are scissioned and an isotactic arrangement of chains is partially destroyed. Moreover, the new carbonyl groups (C=O) are observed, which signifies oxidation. The UV-vis spectra shows a red shift in the absorption edge from pristine value of 240 to 380 nm, which corresponds to decrease in the optical band gap from 5.17 to 3.27 eV. This is because of the formation of conjugated double bonds as well as carbonization. The crystalline properties were analysed using XRD and it shows no profound change. This result may attribute that the radiation-induced changes have probably occurred to a large extent in amorphous regions. However, surface morphology by SEM and contact angle measurements showed considerable surface roughening, which indicates an uneven evolution of gases from the surface. Interestingly, the surface hardness of the films was found to increase with fluence and it may be due to crosslinking and carbonization on the surface. Overall, in conclusion this study shows considerable modifications in the physicochemical properties of isotactic polypropylene irradiated by 6 MeV energy pulsed electrons.

  18. 7-MeV electron LINAC based pulse radiolysis facility at RPCD, BARC

    International Nuclear Information System (INIS)

    Naik, C.B.; Nadkarni, S.A.; Toley, M.A.; Shinde, S.J.; Naik, P.D.

    2017-01-01

    7-MeV electron LINAC based pulse radiolysis facility is operational in Chemistry Group of BARC since 1986. The Accelerator is housed in B-132 room in basement of Modular Labs. BARC Accelerator was procured from Radiation Dynamics Inc. UK and its detection system was indigenously developed

  19. CESAR, 2 MeV electron storage ring; construction period; general view.

    CERN Multimedia

    Service Photo; CERN PhotoLab

    1962-01-01

    A general view of the 2-MeV electron storage-ring model during the last stages of assembly. The injection line for the electrons enters at the bottom of the picture (under the ladder) and meets the ring at the back, to the right. Near there, Joseph Karouanton (S.G.T.E, Paris) (inside the ring), and Marcel Bernasconi (AR Division) are seen testing for leaks in the vacuum system. In white coats are Mervin Barnes (left) and Boony Bruggerman (AR Division), considering the reading shown by one of the vacuum gauges.

  20. Temperature and 8 MeV electron irradiation effects on GaAs solar cells

    Indian Academy of Sciences (India)

    1Department of Physics, Mangalore Institute of Technology and Engineering, ... strate were irradiated with 1 MeV electrons, they showed high radiation tolerance ... under both forward and reverse bias in the temperature range of 270–315 K ...

  1. Dislocation Climb Sources Activated by 1 MeV Electron Irradiation of Copper-Nickel Alloys

    DEFF Research Database (Denmark)

    Barlow, P.; Leffers, Torben

    1977-01-01

    Climb sources emitting dislocation loops are observed in Cu-Ni alloys during irradiation with 1 MeV electrons in a high voltage electron microscope. High source densities are found in alloys containing 5, 10 and 20% Ni, but sources are also observed in alloys containing 1 and 2% Ni. The range of ...

  2. 12 MeV, 4.3 kW electron linear accelerator irradiation application

    International Nuclear Information System (INIS)

    Hang Desheng; Lai Qiji

    2000-01-01

    Characteristics of an electron linear accelerator, which has 6-12 MeV energy, 4.2 kW average beam power is introduced. Results show that it has advantages on improving the characteristics of semiconductor devices such as diodes, triodes, SCR, preventing garlic from sprout, preservation of food, and so on

  3. High-resolution inelastic electron scattering on 208Pb at 50 and 63.5 MeV and fragmentation of the magnetic quadrupole strength

    International Nuclear Information System (INIS)

    Knuepfer, W.; Frey, R.; Richter, A.; Schwierczinski, A.; Spamer, E.; Titze, O.

    1977-12-01

    High-resolution inelastic electron scattering (FWHM approximately equal to 33 keV) with 50 MeV and 63.5 MeV electrons on 208 Pb has been used to study magnetic excitations between Esub(x) = 6 MeV and 8 MeV. Angular distributions were analyzed in terms of the DWBA with RPA wave functions. Eight Isup(π) = 2- states carrying a total strength ΣB(M2) = 8500 μ 2 sub(K) fm 2 have been found. The strong fragmentation is in qualitative agreement with theoretical predictions. (orig.) [de

  4. Estimation of the measurement effective point in cylindrical ionization chamber used in electron beams with energies between 6 and 20 MeV

    International Nuclear Information System (INIS)

    Araujo, M.M. de.

    1984-01-01

    The radial displacement was determined in a water phantom for electrons beams at energies from 6 to 20 MeV for three commercial cylindrical ionization chambers of internal diameters varying from 3.5 to 9.0 mm. The chambers were irradiated with the main axis perpendicular to the direction of the beam. A 300 V bias voltage was applied and readings were taken with both polarities. It was observed that, with increasing depth in the water phantom, the radial displacement remains constant for the 8.9 MeV beam, it increases for the 12.6 MeV electrons and decreases for those of 16.8 and 19.7 MeV. A theoretical model was built in order to calculate the displacement of the effective point of measurement. The Fermi-Eyges multiple scattering theory and a retangular beam normalism developed by Jette (1983) for therapeutic electron beam are used. It was found that the radial displacement stays constant with increasing depth and it decreases with increasing average energy of the incident beam. The model also predicts that the displacement is dependent on the chamber radius. The experimental and theoretical results are compared. They show good agreement for 8.9 and 12.6 MeV electrons, while for 16.8 and 19.7 MeV electrons they indicate that modifications in the theoretical model are necessary. (Author) [pt

  5. Design of scan-horn and beam extraction window for a 3 MeV electron accelerator

    International Nuclear Information System (INIS)

    Ghodke, S.R.; Acharya, S.; Puthran, G.P.; Majumder, R.; Mittal, K.C.; Mahendra Kumar; Sethi, R.C.

    2003-01-01

    A 3 MeV, 30 kW D.C. electron accelerator is being developed for installation at the Electron Beam Center at Khargar, Navi Mumbai to cater to industrial uses like cable irradiation. This paper describes the design of the scan horn and beam extraction window of this accelerator. (author)

  6. Effect of 1.5 MeV electron irradiation on β-Ga2O3 carrier lifetime and diffusion length

    Science.gov (United States)

    Lee, Jonathan; Flitsiyan, Elena; Chernyak, Leonid; Yang, Jiancheng; Ren, Fan; Pearton, Stephen J.; Meyler, Boris; Salzman, Y. Joseph

    2018-02-01

    The influence of 1.5 MeV electron irradiation on minority transport properties of Si doped β-Ga2O3 vertical Schottky rectifiers was observed for fluences up to 1.43 × 1016 cm-2. The Electron Beam-Induced Current technique was used to determine the minority hole diffusion length as a function of temperature for each irradiation dose. This revealed activation energies related to shallow donors at 40.9 meV and radiation-induced defects with energies at 18.1 and 13.6 meV. Time-resolved cathodoluminescence measurements showed an ultrafast 210 ps decay lifetime and reduction in carrier lifetime with increased irradiation.

  7. Focusing of relativistic electron bunch, moving in cylindrical plasma waveguide

    International Nuclear Information System (INIS)

    Amatuni, A.Ts.; Ehlbakyan, S.S.; Sekhpossyan, E.V.

    1994-01-01

    The problem on the focusing of electron bunches moving with the relativistic velocity along the axis of cylindrical overdense plasma waveguide with the conducting internal surface is considered. The existence of periodic and nonperiodic components of the fields, generated in the plasma is shown. The conditions of electron bunch self-focusing by transverse electrical field and azimuthal magnetic field are derived. The possibility of the acceleration and focusing of electron or positron bunches by driving electron bunch wake field is discussed. The conditions, when the bunch in plasma waveguide moves without wake fields generating are obtained, which could be of the interest for the transport of relativistic electron (positron) bunches. 5 refs

  8. Calibration of a silicon semiconductor detecter using a 2 MeV electron accelerator beam

    International Nuclear Information System (INIS)

    Fleurot, N.; Gouard, P.; Mazataud, E.; Nail, M.; Savy, C.; Bayer, C.; Cauchois, Y.; Kherouf, R.; Mathieu, D.

    1981-01-01

    This paper describes the current mode calibration, carried out on a 2 MeV electron accelerator, of PIN detectors involved in electron spectrum measurements for laser-matter interaction experiments. A theoretical analysis simulating the interaction between the incident electrons and the irradiated medium has been carried out using the FOTELEC code. It accounts well for the experimental results giving a reasonable value for the mean electron-hole pair formation energy when back-scattering corrections are included. This work provides the transfer function data required for a plasma diagnostic spectrometer. (orig.)

  9. Photoreactivity in Saccharomyces cerevisiae cells after irradiation with 25 MeV electrons

    International Nuclear Information System (INIS)

    Tsyb, T.S.; Seleva, N.G.; Myasnik, M.N.; Kabakova, N.M.

    1986-01-01

    Significant photoreactivation was noted in radio- and UV-sensitive rad-mutants of Saccharomyces cerevisiae cells exposed to 25 MeV electrons. In order to make the photoreactivable damage be manifest anoxic conditions of irradiation should be chosen as optimal ones. It was shown that the low oxygen effect was partially associated with the photoreactivable damage involved in the lethal effect of ionizing radiation

  10. 6 MeV pulsed electron beam induced surface and structural changes in polyimide

    Energy Technology Data Exchange (ETDEWEB)

    Mathakari, Narendra L.; Bhoraskar, Vasant N. [Microtron Accelerator Laboratory, Department of Physics, University of Pune, Ganeshkhind, Pune 411007, Maharashtra (India); Dhole, Sanjay D., E-mail: sanjay@physics.unipune.ernet.i [Microtron Accelerator Laboratory, Department of Physics, University of Pune, Ganeshkhind, Pune 411007, Maharashtra (India)

    2010-04-15

    Thin films of polyimide (PMDA-ODA, Kapton) having 50 mum thickness were irradiated with 6 MeV pulsed electron beam. The bulk and surface properties of pristine and irradiated samples were characterized by several techniques such as stress-strain measurements, Fourier Transform Infrared (FTIR), UV-vis spectroscopy, contact angle, atomic force microscopy (AFM) and profilometry. The tensile strength, percentage elongation and strain energy show an enhancement from pristine value of 73-89 MPa, 10-22% and 4.75-14.2 MJ/m{sup 3} respectively at the maximum fluence of 4 x 10{sup 15} electrons/cm{sup 2}. This signifies that polyimide being an excessively aromatic polymer is crosslinked due to high-energy electron irradiation. In surface properties, the contact angle shows a significant decrease from 59 deg. to 32 deg. indicating enhancement in hydrophilicity. This mainly attributes to surface roughening, which is due to the electron beam induced sputtering. The surface roughening is confirmed in AFM and profilometry measurements. The AFM images clearly show that surface roughness increases after electron irradiation. Moreover, the roughness average (R{sub a}) as measured from surface profilograms is found to increase from 0.06 to 0.1. The FTIR and UV-vis spectra do not show noticeable changes as regards to scissioning of bonds and the oxidation. This work leads to a definite conclusion that 6 MeV pulsed electron beam can be used to bring about desired changes in surface as well as bulk properties of polyimide, which is considered to be a high performance space quality polymer.

  11. Revealing by secondary electronic emission of internal electric fields in the yttriated zirconia, irradiated by electrons of 1 MeV

    International Nuclear Information System (INIS)

    Blaise, G.; Paris-11 Univ., 91 - Orsay

    2007-01-01

    The defects due to irradiation in a dielectric material present an activity which can generate macroscopic internal electric fields. A method of investigation of these fields, based on the measure of the Secondary Electronic Emission coefficient, has been developed on a scanning electric microscope. This ones contains two low noise detectors which respectively measure the influence current I IC produced by the charges trapping in the material and the current I SB due to secondary and backscattered electrons which come from the sample. The Secondary Emission coefficient is given by σ=I SB /(I SB +I IC ). The charges trapping during an electrons injection leads to a variation of σ for its intrinsic value σ 0 relative to the uncharged material, until the stationary value σ st =1 corresponding to the auto-regulated condition. This variation is due to the development of an internal electric field produced by the accumulation of the charges trapped during injection. In comparing the evolutions of σ of a fresh yttriated zirconia and of an yttriated zirconia irradiated by electrons of 1 MeV with a dose rate of 10 18 e/cm 2 , it has been revealed that an internal field (due to irradiation) of about 0.5*10 6 V/m exists at a depth of the micron order. This field, directed towards the outside of the material surface, is attributed to the F + defects and to the T centers produced by the impact of the electrons of 1 MeV. In carrying out annealings until 1000 K, a progressive disappearance of this field is observed in the temperature range of 400-600 K, directly due to the F + defects and T centers recovery, as it has been observed by ESR. An internal field three times weaker than the preceding ones has been revealed at a few nm under the surface. Its disappearance from a temperature of 1000 K suggests that it is due to the redistribution of the chemical species into the surface, during the irradiation with electrons of 1 MeV. (O.M.)

  12. Photonuclear and Radiation Effects Testing with a Refurbished 20 MeV Medical Electron Linac

    CERN Document Server

    Webb, Timothy; Beezhold, Wendland; De Veaux, Linda C; Harmon, Frank; Petrisko, Jill E; Spaulding, Randy

    2005-01-01

    An S-band 20 MeV electron linear accelerator formerly used for medical applications has been recommissioned to provide a wide range of photonuclear activation studies as well as various radiation effects on biological and microelectronic systems. Four radiation effect applications involving the electron/photon beams are described. Photonuclear activation of a stable isotope of oxygen provides an active means of characterizing polymer degradation. Biological irradiations of microorganisms including bacteria were used to study total dose and dose rate effects on survivability and the adaptation of these organisms to repeated exposures. Microelectronic devices including bipolar junction transistors (BJTs) and diodes were irradiated to study photocurrent from these devices as a function of peak dose rate with comparisons to computer modeling results. In addition, the 20 MeV linac may easily be converted to a medium energy neutron source which has been used to study neutron damage effects on transistors.

  13. A measurement of auroral electrons in the 1–10 MeV range

    NARCIS (Netherlands)

    Gils, J.N. van; Beek, H.F. van; Fetter, L.D. de; Hendrickx, R.V.

    Particle fluxes have been measured by means of shielded Geiger-Müller telescopes mounted m a rocket, which was launched from ESRANGE(Kiruna) into a diffuse aurora. The analysis of the dependence of the counting rates on altitude indicates that a weak flux of energetic electrons, 1–10 MeV, has been

  14. Utilization of 5 MeV electron accelerator center and perspective

    International Nuclear Information System (INIS)

    Tanaka, Hiromi

    1990-01-01

    Electron beam process gives instantaneous effect as compared with heating process, and has such merits that energy consumption is very small, objects can be treated from outside, harmful chemicals are not used and treatment can be done as packed. The spread of electron beam process is largely due to the results of the development of highly reliable accelerators and utilization technologies, but as observed from all industrial fields, it is limited to only a part. In order to contribute to the solution of problems and the spread of electron beam process, Sumitomo Heavy Industries, Ltd. installed a 5 MeV, 200 kW large power accelerator developed by RDI in USA in the Electron Irradiation Application and Development Center opened in Tsukuba City. The Center was completed in June, 1989, and has carried out the activities of the development of irradiation utilization technologies, test irradiation and entrusted irradiation service. The features of electron beam process are high dose rate, the possibility of on and off as occasion demands, the preparation of radiation sources and the disposal of wastes being unnecessary, and no environmental problem. The industrialized processes, the types, energy and use of electron accelerators, the Tsukuba irradiation facilities and others are reported. (K.I.)

  15. Radiation damage of silicon structures with electrons of 900 MeV

    CERN Document Server

    Rachevskaia, I; Bosisio, L; Dittongo, S; Quai, E; Rizzo, G

    2002-01-01

    We present first results on the irradiation of double-sided silicon microstrip detectors and test structures performed at the Elettra synchrotron radiation facility at Trieste, Italy. The devices were irradiated with 900 MeV electrons. The test structures we used for studying bulk, surface and oxide irradiation damage were guard ring diodes, gated diodes and MOS capacitors. The test structures and the double-sided microstrip detectors were produced by Micron Semiconductor Ltd. (England) and IRST (Trento, Italy). For the first time, bulk-type inversion is observed to occur after high-energy electron irradiation. Current and inter-strip resistance measurements performed on the microstrip detectors show that the devices are still usable after type inversion.

  16. Attenuation of 10 MeV electron beam energy to achieve low doses does not affect Salmonella spp. inactivation kinetics

    International Nuclear Information System (INIS)

    Hieke, Anne-Sophie Charlotte; Pillai, Suresh D.

    2015-01-01

    The effect of attenuating the energy of a 10 MeV electron beam on Salmonella inactivation kinetics was investigated. No statistically significant differences were observed between the D 10 values of either Salmonella 4,[5],12:i:- or a Salmonella cocktail (S. 4,[5],12:i:-, Salmonella Heidelberg, Salmonella Newport, Salmonella Typhimurium, Salmonella) when irradiated with either a non-attenuated 10 MeV eBeam or an attenuated 10 MeV eBeam (~2.9±0.22 MeV). The results show that attenuating the energy of a 10 MeV eBeam to achieve low doses does not affect the inactivation kinetics of Salmonella spp. when compared to direct 10 MeV eBeam irradiation. - Highlights: • 10 MeV eBeam energy was attenuated to 2.9±0.22 MeV using HDPE sheets. • Attenuation of eBeam energy does not affect the inactivation kinetics of Salmonella. • Microbial inactivation is independent of eBeam energy in the range of 3–10 MeV

  17. CESAR, 2 MeV electron storage ring; general view.

    CERN Multimedia

    CERN PhotoLab

    1964-01-01

    CESAR (CERN Electron Storage and Accumulation Ring) was built as a study-model for the ISR (Intersecting Storage Rings). The model had to be small (24 m circumference) and yet the particles had to be highly relativistic, which led to the choice of electrons. On the other hand, in order to model the behaviour of protons, effects from synchrotron radiation had to be negligible, which meant low magnetic fields (130 G in the bending magnets) and a corresponding low energy of 1.75 MeV. All the stacking (accumulation) procedures envisaged for the ISR were proven with CESAR, and critical aspects of transverse stability were explored. Very importantly, CESAR was the test-bed for the ultrahigh vacuum techniques and components, essential for the ISR, with a final pressure of 6E-11 Torr. The CESAR project was decided early in 1960, design was completed in 1961 and construction in 1963. After an experimental period from 1964 to 1967, CESAR was dismantled in 1968.

  18. Performance of the 100 MeV injector linac for the electron storage ring at Kyoto University

    International Nuclear Information System (INIS)

    Shirai, T.; Sugimura, T.; Iwashita, Y.; Kakigi, S.; Fujita, H.; Tonguu, H.; Noda, A.; Inoue, M.

    1996-01-01

    An electron linear accelerator has been constructed as an injector of a 300 MeV electron storage ring (Kaken Storage Ring, KSR) at Institute for Chemical Research, Kyoto University. The output beam energy of the linac is 100 MeV and the designed beam current is 100 mA at the 1 μsec long pulse mode. The transverse and longitudinal emittance are measured to evaluate the beam quality for the beam injection into the KSR. They are observed by the profile monitors combined with quadrupole magnets or an RF accelerator. The results are that the normalized transverse emittance is 120 π.mm.mrad. The longitudinal emittance is 15 π.deg.MeV and the energy spread is ±2.2 %. (author)

  19. MeV gamma-ray observation with a well-defined point spread function based on electron tracking

    Science.gov (United States)

    Takada, A.; Tanimori, T.; Kubo, H.; Mizumoto, T.; Mizumura, Y.; Komura, S.; Kishimoto, T.; Takemura, T.; Yoshikawa, K.; Nakamasu, Y.; Matsuoka, Y.; Oda, M.; Miyamoto, S.; Sonoda, S.; Tomono, D.; Miuchi, K.; Kurosawa, S.; Sawano, T.

    2016-07-01

    The field of MeV gamma-ray astronomy has not opened up until recently owing to imaging difficulties. Compton telescopes and coded-aperture imaging cameras are used as conventional MeV gamma-ray telescopes; however their observations are obstructed by huge background, leading to uncertainty of the point spread function (PSF). Conventional MeV gamma-ray telescopes imaging utilize optimizing algorithms such as the ML-EM method, making it difficult to define the correct PSF, which is the uncertainty of a gamma-ray image on the celestial sphere. Recently, we have defined and evaluated the PSF of an electron-tracking Compton camera (ETCC) and a conventional Compton telescope, and thereby obtained an important result: The PSF strongly depends on the precision of the recoil direction of electron (scatter plane deviation, SPD) and is not equal to the angular resolution measure (ARM). Now, we are constructing a 30 cm-cubic ETCC for a second balloon experiment, Sub-MeV gamma ray Imaging Loaded-on-balloon Experiment: SMILE-II. The current ETCC has an effective area of 1 cm2 at 300 keV, a PSF of 10° at FWHM for 662 keV, and a large field of view of 3 sr. We will upgrade this ETCC to have an effective area of several cm2 and a PSF of 5° using a CF4-based gas. Using the upgraded ETCC, our observation plan for SMILE-II is to map of the electron-positron annihilation line and the 1.8 MeV line from 26Al. In this paper, we will report on the current performance of the ETCC and on our observation plan.

  20. Calibration of imaging plates to electrons between 40 and 180 MeV

    International Nuclear Information System (INIS)

    Rabhi, N.; Batani, D.; Boutoux, G.; Ducret, J.-E.; Bohacek, K.; Guillaume, E.; Thaury, C.; Jakubowska, K.; Thfoin, I.

    2016-01-01

    This paper presents the response calibration of Imaging Plates (IPs) for electrons in the 40-180 MeV range using laser-accelerated electrons at Laboratoire d’Optique Appliquée (LOA), Palaiseau, France. In the calibration process, the energy spectrum and charge of electron beams are measured by an independent system composed of a magnetic spectrometer and a Lanex scintillator screen used as a calibrated reference detector. It is possible to insert IPs of different types or stacks of IPs in this spectrometer in order to detect dispersed electrons simultaneously. The response values are inferred from the signal on the IPs, due to an appropriate charge calibration of the reference detector. The effect of thin layers of tungsten in front and/or behind IPs is studied in detail. GEANT4 simulations are used in order to analyze our measurements.

  1. Detection of electrons in the 10 MeV range by plastic scintillators

    Energy Technology Data Exchange (ETDEWEB)

    Beaudoin, G; Champagne, A; Jeremie, H; Lessard, L

    1986-09-10

    Response functions for electrons from 1 to 12 MeV have been measured with a plastic scintillator telescope. A parametrization model for these response functions has been found to give good results at all energies. Furthermore it was established that the type of reflector used for the scintillator has a considerable influence on the response functions. A mechanism for this influence has been proposed and tested by Monte Carlo calculations.

  2. Experience with the Alderson Rando phantom. [17-MeV electrons

    Energy Technology Data Exchange (ETDEWEB)

    Somerwil, A; Kleffens, H.J. Van [Rotterdams Radio Therapeutisch Instituut (Netherlands)

    1977-04-01

    The dose delivered to the spinal cord is of particular interest in electron beam therapy of medulloblastoma. Lithium fluoride thermoluminescent dosimetry has been used in an assessment of the dose distributions from a 17 MeV electron beam in an Alderson Rando Phantom (Alderson, S.W., Lanzl, L.H., Rollins, M., and Spira, J., 1962, American J. of Roentgenology, Radium Therapy and Nuclear Medicine, vol. 87, 185). Measurements were also made on three autopsy specimens immersed in water. There were substantial differences between the two sets of results. The density of the bony part of the phantom seemed to be markedly lower than that of the water; radiographs of various parts of the phantom confirmed that large areas of low density existed. The manufacturers have stated that in order to simulate true in vivo conditions, an artificial skeleton would have to be introduced into the tissue-like material of the phantom, and that the real skeletons now used appear to be unsuitable for electron beam dosimetry. It is therefore doubtful whether this electron beam dosimetry justifies the expense associated with the insertion of these unsatisfactory skeletons into the soft tissue-equivalent material.

  3. Design and modelling of a 5 MeV radio frequency electron gun

    International Nuclear Information System (INIS)

    Batchelor, K.; Sheehan, J.; Woodle, M.

    1988-01-01

    The Accelerator Test Facility (ATF) at Brookhaven National Laboratory is a linac-laser complex for research into laser acceleration and for the generation of coherent radiation from electron beams. In order to achieve the design 50 MeV output emittance (γσ/sub x/σ/sub x/') of less than 3 /times/ 10/sup /minus/5/ m rad a high brightness electron gun is required. This paper describes computations and measurements made on a full scale brass model of a 1-1/2 cell, π-mode, resonant, disc loaded, radiofrequency gun structure which has been designed for this purpose. 7 refs., 9 figs., 6 tabs

  4. First studies of 500-nm Cherenkov radiation from 255-MeV electrons in a diamond crystal

    Energy Technology Data Exchange (ETDEWEB)

    Takabayashi, Y., E-mail: takabayashi@saga-ls.jp [SAGA Light Source, 8-7 Yayoigaoka, Tosu, Saga 841-0005 (Japan); Fiks, E.I. [National Research Tomsk Polytechnic University, 634050 Tomsk (Russian Federation); Pivovarov, Yu.L. [National Research Tomsk Polytechnic University, 634050 Tomsk (Russian Federation); National Research Tomsk State University, 634050 Tomsk (Russian Federation)

    2015-06-12

    The first experiment on Cherenkov light from 255-MeV electrons passing through a 50-μm-thick diamond crystal in a special geometry allowing extraction of 500-nm Cherenkov light at a right angle with respect to the electron beam direction has been performed at the injector linac of SAGA Light Source accelerator facility. The dependence of 500-nm Cherenkov light intensity (separated by a band-pass filter) on the crystal rotation angle was measured by a CCD detector. The experimentally obtained rocking curve with an intense maximum is theoretically explained as the projector effect of Cherenkov light deflected by the exit surface of the crystal. The width of the rocking curve is explained by the convolution of the standard Tamm–Frank angular distribution of Cherenkov radiation with chromatic aberration, the multiple scattering of electrons in a crystal, and initial electron beam angular divergence. In addition, it is found that the Cherenkov light intensity did not change under the (220) planar channeling condition, which is consistent with a recent theory. - Highlights: • Cherenkov light from 255-MeV electrons in a diamond crystal has been investigated. • The Cherenkov light from channeled electrons has been observed for the first time. • The experimental results are in good agreement with theory.

  5. Subnanosecond pulsing of an 1 MeV ELIT electron accelerator by beam deflection

    International Nuclear Information System (INIS)

    Vasserman, S.B.; Kuzenko, V.; Mehnert, R.; Hermann, R.

    1984-01-01

    Operation principle and performance of a beam deflection system developed for subnanosecond pulsing of an 1 MeV ELIT resonance transformer accelerator are described. Using this system a minimum pulse duration of 0.5 ns (FWHM) and a dose per pulse of about 20 Gy were obtained. As an example the fluorescence of cyclohexane excited by the subnanosecond electron pulse was measured. (author)

  6. Effect of MeV Electron Radiation on Europa’s Surface Ice Analogs

    Science.gov (United States)

    Gudipati, Murthy; Henderson, Bryana; Bateman, Fred

    2017-10-01

    MeV electrons that impact Europa’s trailing hemisphere and cause both physical and chemical alteration of the surface and near-surface. The trailing hemisphere receives far lower fluxes above 25 MeV as compared with lower energy particles, but can cause significant chemical and physical modifications at these energies. With NASA's planned Europa Clipper mission and a Europa Lander Concept on the horizon, it is critical to understand and quantify the effect of Europa’s radiation environment on the surface and near surface.Electrons penetrate through ice by far the deepest at any given energy compared to protons and ions, making the role of electrons very important to understand. In addition, secondary radiation - Bremsstrahlung, in X-ray wavelengths - is generated during high-energy particle penetration through solids. Secondary X-rays are equally lethal to life and penetrate even deeper than electrons, making the cumulative effect of radiation on damaging organic matter on the near surface of Europa a complex process that could have effects several meters below Europa’s surface. Other physical properties such as coloration could be caused by radiation.In order to quantify this effect under realistic Europa trailing hemisphere conditions, we devised, built, tested, and obtained preliminary results using our ICE-HEART instrument prototype totally funded by JPL’s internal competition funding for Research and Technology Development. Our Ice Chamber for Europa High-Energy Electron And Radiation-Environment Testing (ICE-HEART) operates at ~100 K. We have also implemented a magnet that is used to remove primary electrons subsequent to passing through an ice column, in order to determine the flux of secondary X-radiation and its penetration through ice.Some of the first results from these studies will be presented and their relevance to understand physical and chemical properties of Europa’s trailing hemisphere surface.This work has been carried out at Jet

  7. Radiation from 39 and 45 MEV electrons channeled in lithium niobate

    Energy Technology Data Exchange (ETDEWEB)

    Diedrich, E.; Kufner, W.; Buschhorn, G. (Max-Planck-Institut fuer Physik und Astrophysik, Muenchen (Germany). Werner-Heisenberg-Inst. fuer Physik)

    1991-12-01

    Channeling radiation from 39 and 45 MeV electrons channeled along the (0001) axis, the (0110) plane and the (1210) plane of a 30 {mu}m thick LiNbO{sub 3} crystal has been measured. Calculations of the planar crystal potentials were performed by means of the many-beam formalism. Good agreement between theory and experiment is obtained for the planar channeling radiation. Associated with channeling, additional radiation lines have been observed, which may be explained by a periodic perturbation of the continuum potential. (author).

  8. Angular distributions for the charged components in a cascade shower induced by 350 MeV electrons

    International Nuclear Information System (INIS)

    Kobayashi, S.; Itoh, H.; Murakami, A.; Muto, T.

    1978-01-01

    The angular distributions of secondary electrons contained in a cascade shower are studied by using a streamer chamber. The primary electrons with energy of about 350 MeV are incident on a lead converter of various thickness. The angular data are analyzed for the number of electrons in a shower, and for the converter thickness. The obtained distributions show a systematic agreement with the Monte Carlo calculations presented by Messel and Crawford. (Auth.)

  9. Coherent bremsstrahlung and channeling radiation from electrons of one to three MeV in silicon and gold

    International Nuclear Information System (INIS)

    Watson, J.E.

    1981-01-01

    The observation of sharp peaks in the x-ray spectrum from 1 to 3 MeV electrons striking thin single crystals of silicon and gold is reported. These peaks were observed in the range 1 to 25 keV. The peaks are of two different origins, both direct results of the periodic nature of the target crystals. The first kind of radiation is caused by the interference of incoming and scattered electron wave functions. Because of the periodicity of the target material there is a coherence effect for certain bremsstrahlung wave vectors. This coherent bremsstrahlung, though well known at very high electron energies, has never been adequately studied at electron energies below several hundred MeV. Detailed agreement between theoretical prediction and observation in silicon is shown. The second kind of radiation is caused by electrons channeled along major crystal axes. The electrons enter certain quantized orbits as they channel and may emit photons as a consequence of transitions between the various orbits. Observations of channeling radiation for various crystal axes in silicon are presented. Both phenomena were observed in gold, the first such observation for any metallic target

  10. Physics design of a 10 MeV, 6 kW travelling wave electron linac

    Indian Academy of Sciences (India)

    We present the physics design of a 10 MeV, 6 kW S-band (2856 MHz) electron linear accelerator (linac), which has been recently built and successfully operated at Raja Ramanna Centre for Advanced Technology, Indore. The accelerating structure is a 2 π / 3 mode constant impedance travelling wave structure, which ...

  11. Electron orbits in the microwave inverse FEL accelerator (MIFELA)

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, T.B.; Marshall, T.C. [Columbia Univ., New York, NY (United States)

    1995-12-31

    The MIFELA is a new device based on stimulated absorption of microwaves by electrons moving along an undulator. An intense microwave field is used (a{sub s} = eE{sub s}/k{sub s} m c{sup 2} = 0.2) as well as a large undulator field (a{sub w}/{gamma} = eB{sub {perpendicular}}/{gamma}k{sub w} mc{sup 2} = 1/2) to accelerate electrons emitted at 6MeV from a rf gun to 20MeV in 1.5m. The spiral radius of the electrons in the undulator is 8mm, in a waveguide of diameter 34mm, with undulator period about 10cm. There is a small guiding field, and the electrons move in type I orbits. We describe three problems connected with the orbital motion of the electrons in this structure: (i) injecting the electrons in an increasing undulator field prior to entering the MIFELA; (ii) orbital motion and stability inside the MIFELA; (iii) extraction of electrons from the spiral orbit in the accelerator into an axially-propagating beam, obtaining {Beta}{sub {perpendicular}} < 0.02. These studies have application to a MIFELA which is under construction at Yale University by Omega-P.

  12. Design of cavities of a standing wave accelerating tube for a 6 MeV electron linear accelerator

    Directory of Open Access Journals (Sweden)

    S Zarei

    2017-08-01

    Full Text Available Side-coupled standing wave tubes in  mode are widely used in the low-energy electron linear accelerator, due to high accelerating gradient and low sensitivity to construction tolerances. The use of various simulation software for designing these kinds of tubes is very common nowadays. In this paper, SUPERFISH code and COMSOL are used for designing the accelerating and coupling cavities for a 6 MeV electron linear accelerator. Finite difference method in SUPERFISH code and Finite element method in COMSOL are used to solve the equations. Besides, dimension of accelerating and coupling cavities and also coupling iris dimension are optimized to achieve resonance frequency of 2.9985 MHz and coupling constant of 0.0112. Considering the results of this study and designing of the RF energy injection port subsequently, the construction of 6 MeV electron tube will be provided

  13. 238U and 237Np nuclear fission by 90-270 MeV electrons

    International Nuclear Information System (INIS)

    Kuznetsov, V.L.; Nedorezov, V.G.; Nikitina, N.V.; Noga, V.I.; Ranyuk, Yu.N.; Telegin, Yu.N.; Smirnov, A.N.; Ehjsmont, V.P.

    1981-01-01

    A technique for measuring cross sections of 238 U and 237 Np nuclei fission caused by 90-270 MeV electrons is described. Measurement results are given. The results obtained are discussed on the basis of the virtual photon method. It is shown that the difference in cross sections of 238 U and 237 Np electrofission is due to the different contribution of the giant resonance [ru

  14. Identification of defects in GaAs induced by 1 MeV electron irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Lai, S.T.; Nener, B.D.; Faraone, L.; Nassibian, A.G. [Western Australia Univ., Nedlands, WA (Australia); Hotchkis, M.A.C. [Australian Nuclear Science and Technology Organisation, Lucas Heights, NSW (Australia)

    1993-12-31

    This paper shows that 1 MeV electron irradiation on n-type vapor phase epitaxial (VPE) GaAs creates three electron traps E1, E2 and EL6, and results in the splitting of the EL2 center into two levels EL2-A and EL2-B. A 15 minutes isochronal anneal results in the annihilation of the E1 and E2 traps, a reduction in EL6 trap concentration, and the return of EL2 to a single level EL2-A. A defect model is outlined which correlates with the observed results. 4 refs., 2 tabs., 3 figs.

  15. Identification of defects in GaAs induced by 1 MeV electron irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Lai, S T; Nener, B D; Faraone, L; Nassibian, A G [Western Australia Univ., Nedlands, WA (Australia); Hotchkis, M A.C. [Australian Nuclear Science and Technology Organisation, Lucas Heights, NSW (Australia)

    1994-12-31

    This paper shows that 1 MeV electron irradiation on n-type vapor phase epitaxial (VPE) GaAs creates three electron traps E1, E2 and EL6, and results in the splitting of the EL2 center into two levels EL2-A and EL2-B. A 15 minutes isochronal anneal results in the annihilation of the E1 and E2 traps, a reduction in EL6 trap concentration, and the return of EL2 to a single level EL2-A. A defect model is outlined which correlates with the observed results. 4 refs., 2 tabs., 3 figs.

  16. Optimization of beam parameters of electron gun for 2.5 MeV/100 kW high power industrial accelerator

    International Nuclear Information System (INIS)

    Pramod, R.; Petwal, V.C.

    2009-01-01

    A 2.5 MeV/100 kW transformer type industrial accelerator is being developed at RRCAT. A Pierce type electron gun consisting of 10 mm diameter LaB 6 disc (indirectly heated) is used as a source of electron beam. The cathode assembly is put on the top of the accelerating structure, which consists of many electrostatic lenses of which the first lens acts as anode of the gun. The quality of the beam injected into the accelerating structure depends on the anode voltage, shape and size of anode and its distance from the cathode. The anode is subjected to variable voltage during the operation of accelerator from energy 1 MeV to 2.5 MeV, which results in variable emittance at the exit of the electron gun. The electron beam from the gun should provide parallel or slightly convergent beam with long focal length and the emittance of the beam at the exit of electron gun should match the beam acceptance limit of the accelerating structure. The EGUN code is used to optimize the shape and size of the anode, its distance from the cathode to achieve above objectives. Our study suggests that the desired beam parameters at the exit of the anode can be obtained by reducing the aperture size of the anode and by applying suitable voltage gradient to the anode. (author)

  17. Electromagnetic design and beam dynamics studies for a 10 MeV, 10 kW electron linac

    International Nuclear Information System (INIS)

    Dhingra, Rinky; Kulkarni, Nita S.; Kumar, Vinit

    2013-01-01

    Bi-periodic on-axis coupled standing wave linac is seen as an attractive choice for low energy (∼10 MeV) electron accelerators for industrial applications. In this paper, we present the physics design of an S-band bi-periodic on-axis coupled standing wave structure operating in π/2 mode. The structure operates at 2856 MHz and can accelerate electrons to 10 MeV. The 2D optimization of structure cells carried out using SUPERFISH is reported. Magnetic coupling is achieved through bean shaped coupling slots. Analytical calculations have been carried out to fix the dimensions of coupling slots. The paper discusses the complete 3D design of accelerating structure with coupling slots carried out using CST-MWS. The approach used to achieve confluence is outlined. Finally, the beam dynamics studies carried out using PARMELA are also discussed. (author)

  18. Dislocation Loops with a Burgers Vector Produced by 1 MeV Electron Irradiation in FCC Copper-Nickel

    DEFF Research Database (Denmark)

    Leffers, Torben; Barlow, P.

    1975-01-01

    Dislocation loops with Burgers vector a are formed in Cu-Ni alloys during 1 MeV electron irradiation in a high-voltage electron microscope at 350°-400°C. The dislocation loops are of interstitial type and pure edge in character with line vectors. Some of the loops are seen to dissociate into loop...

  19. Energy distribution of 0. 279 MeV gamma rays Compton scattered from bound electrons

    Energy Technology Data Exchange (ETDEWEB)

    Singh, B; Singh, P; Singh, G; Ghumman, B S

    1984-11-01

    Energy and intensity distribution of 0.279 MeV gamma rays Compton scattered from K-shell electrons of tantalum is measured at scattering angle of 70deg. The experimental results are compared with the available theoretical data. Spectral distribution is also obtained as a function of scatterer thickness to account for the contribution of false events. 13 refs.

  20. Study of imaging plate detector sensitivity to 5-18 MeV electrons

    Energy Technology Data Exchange (ETDEWEB)

    Boutoux, G., E-mail: boutoux@celia.u-bordeaux1.fr; Rabhi, N.; Batani, D.; Ducret, J.-E. [Univ. de Bordeaux, CNRS, CEA, CELIA (Centre Lasers Intenses et Applications), UMR 5107, F-33405 Talence (France); Binet, A.; Nègre, J.-P.; Reverdin, C.; Thfoin, I. [CEA DAM DIF, F-91297 Arpajon (France); Jakubowska, K. [Institute of Plasma Physics and Laser Microfusion, Hery Street 23, 01-497 Warsaw (Poland)

    2015-11-15

    Imaging plates (IPs) are commonly used as passive detectors in laser-plasma experiments. We calibrated at the ELSA electron beam facility (CEA DIF) the five different available types of IPs (namely, MS-SR-TR-MP-ND) to electrons from 5 to 18 MeV. In the context of diagnostic development for the PETawatt Aquitaine Laser (PETAL), we investigated the use of stacks of IP in order to increase the detection efficiency and get detection response independent from the neighboring materials such as X-ray shielding and detector supports. We also measured fading functions in the time range from a few minutes up to a few days. Finally, our results are systematically compared to GEANT4 simulations in order to provide a complete study of the IP response to electrons over the energy range relevant for PETAL experiments.

  1. Calculations of the electron-damping force on moving-edge dislocations

    International Nuclear Information System (INIS)

    Mohri, T.

    1982-11-01

    Dynamic effect of a moving dislocation has been recognized as one of essential features of deformation behavior at very low temperatures. Damping mechanisms are the central problems in this field. Based on the free-electron-gas model, the electron-damping force (friction force) on a moving-edge dislocation in a normal state is estimated. By applying classical MacKenzie-Sondheimer's procedures, the electrical resistivity caused by a moving dislocation is first estimated, and the damping force is calculated as a Joule-heat-energy dissipation. The calculated values are 3.63x10 - 6 , 7.62x10 - 7 and 1.00x10 - 6 [dyn sec/cm - 2 ] for Al, Cu and Pb, respectively. These values show fairly good agreements as compared with experimental results. Also, numerical calculations are carried out to estimate magnetic effects caused by a moving dislocation. The results are negative and any magnetic effects are not expected. In order to treat deformation behavior at very low temperatures, a unification of three important deformation problems is attempted and a fundamental equation is derived

  2. Effect of the energy of recoil atoms on conductivity compensation in moderately doped n-Si and n-SiC under irradiation with MeV electrons and protons

    Energy Technology Data Exchange (ETDEWEB)

    Kozlovski, V.V. [St. Petersburg State Polytechnic University, St. Petersburg 195251 (Russian Federation); Lebedev, A.A., E-mail: shura.lebe@mail.ioffe.ru [Ioffe Physical Technical Institute, Russian Academy of Sciences, St. Petersburg 194021 (Russian Federation); National Research University of Information Technologies, Mechanics, and Optics, St. Petersburg 197101 (Russian Federation); Emtsev, V.V.; Oganesyan, G.A. [Ioffe Physical Technical Institute, Russian Academy of Sciences, St. Petersburg 194021 (Russian Federation)

    2016-10-01

    Processes of radiation defect formation and conductivity compensation in silicon and silicon carbide irradiated with 0.9 MeV electrons are considered in comparison with the electron irradiation at higher energies. The experimental values of the carrier removal rate at the electron energy of 0.9 MeV are nearly an order of magnitude smaller than the similar values of the parameter for higher energy electrons (6–9 MeV). At the same time, the formation cross-section of primary radiation defects (Frenkel pairs, FPs) is nearly energy-independent in this range. It is assumed that these differences are due to the influence exerted by the energy of primary knocked-on atoms (PKAs). As the PKA energy increases, the average distance between the genetically related FPs grows and, as a consequence, the fraction of FPs unrecombined under irradiation becomes larger. The FP recombination radius is estimated (∼1.1 nm), which makes it possible to ascertain the charge state of the recombining components. Second, the increase in the PKA energy enables formation of new, more complex secondary radiation defects. At electron energies exceeding 15 MeV, the average PKA energies are closer to the values obtained under irradiation with 1 MeV protons, compared with an electron irradiation at the same energy. As for the radiation-induced defect formation, the irradiation of silicon with MeV protons can be, in principle, regarded as a superposition of the irradiation with 1 MeV electrons and that with silicon ions having energy of ∼1 keV, with the “source” of silicon ions generating these ions uniformly across the sample thickness.

  3. MeV electron acceleration at 1kHz with <10 mJ laser pulses

    Science.gov (United States)

    Salehi, Fatholah; Goers, Andy; Hine, George; Feder, Linus; Kuk, Donghoon; Kim, Ki-Yong; Milchberg, Howard

    2016-10-01

    We demonstrate laser driven acceleration of electrons at 1 kHz repetition rate with pC charge above 1MeV per shot using required for relativistic self-focusing low enough for mJ scale laser pulses to self- focus and drive strong wakefields. Experiments and particle-in-cell simulations show that optimal drive pulse duration and chirp for maximum electron bunch charge and energy depends on the target gas species. High repetition rate, high charge, and short duration electron bunches driven by very modest pulse energies constitutes an ideal portable electron source for applications such as ultrafast electron diffraction experiments and high rep. rate γ-ray production. This work is supported by the US Department of Energy, the National Science Foundation, and the Air Force Office of Scientific Research.

  4. Diffusion of interstitial atoms in FCC metals after irradiation with 2 MeV electrons

    International Nuclear Information System (INIS)

    Kornmann, H.

    1980-01-01

    Selfdiffusion in nickel after electron irradiation has been restudied. The diffusion velocity near the surface and the diffusion constant in the interior of the crystal have been determined as a function of radiation flux and temperature. A special method for the measurement of diffusion has been improved, which is based on radioactive tracer atoms for indication and on ion etching for the removal of thin films. To improve additionally the accuracy of the technique tracer atoms are induced into the crystal by thermal diffusion and then irradiated with 2 MeV electrons. (orig./GSCH) [de

  5. Lateral propagation of MeV electrons generated by femtosecond laser irradiation

    International Nuclear Information System (INIS)

    Seely, J. F.; Szabo, C. I.; Audebert, P.; Brambrink, E.; Tabakhoff, E.; Hudson, L. T.

    2010-01-01

    The propagation of MeV electrons generated by intense (≅10 20 W/cm 2 ) femtosecond laser irradiation, in the lateral direction perpendicular to the incident laser beam, was studied using targets consisting of irradiated metal wires and neighboring spectator wires embedded in electrically conductive (aluminum) or resistive (Teflon) substrates. The K shell spectra in the energy range 40-60 keV from wires of Gd, Dy, Hf, and W were recorded by a transmission crystal spectrometer. The spectra were produced by 1s electron ionization in the irradiated wire and by energetic electron propagation through the substrate material to the spectator wire of a different metal. The electron range and energy were determined from the relative K shell emissions from the irradiated and spectator wires separated by varying substrate lateral distances of up to 1 mm. It was found that electron propagation through Teflon was inhibited, compared to aluminum, implying a relatively weak return current and incomplete space-charge neutralization. The energetic electron propagation in the direction parallel to the electric field of the laser beam was larger than perpendicular to the electric field. Energetic electron production was lower when directly irradiating aluminum or Teflon compared to irradiating the heavy metal wires. These experiments are important for the determination of the energetic electron production mechanism and for understanding lateral electron propagation that can be detrimental to fast-ignition fusion and hard x-ray backlighter radiography.

  6. A Complete Reporting of MCNP6 Validation Results for Electron Energy Deposition in Single-Layer Extended Media for Source Energies <= 1-MeV

    Energy Technology Data Exchange (ETDEWEB)

    Dixon, David A. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Hughes, Henry Grady [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-05-04

    In this paper, we expand on previous validation work by Dixon and Hughes. That is, we present a more complete suite of validation results with respect to to the well-known Lockwood energy deposition experiment. Lockwood et al. measured energy deposition in materials including beryllium, carbon, aluminum, iron, copper, molybdenum, tantalum, and uranium, for both single- and multi-layer 1-D geometries. Source configurations included mono-energetic, mono-directional electron beams with energies of 0.05-MeV, 0.1-MeV, 0.3- MeV, 0.5-MeV, and 1-MeV, in both normal and off-normal angles of incidence. These experiments are particularly valuable for validating electron transport codes, because they are closely represented by simulating pencil beams incident on 1-D semi-infinite slabs with and without material interfaces. Herein, we include total energy deposition and energy deposition profiles for the single-layer experiments reported by Lockwood et al. (a more complete multi-layer validation will follow in another report).

  7. Dosimetric evaluation of multi-sided irradiation on HDPE pipes under 2 MeV electron beam

    Energy Technology Data Exchange (ETDEWEB)

    Benny, P.G., E-mail: bennypg@yahoo.com; Khader, S.A.; Sarma, K.S.S.

    2014-03-01

    The use of electron beam technology has enabled the production of heat resistant pipe for hot water circulation. One of the difficulties in the irradiation of pipe products is the uneven penetration of electrons. Quality of the radiation process depends on radiation dose and homogeneity of the dose distribution, which becomes a major concern when treatments of circular objects like pipes are performed. One method to achieve uniformity in the absorbed dose in the product is to use multi-sided irradiation. The paper discusses the importance of dosimetry mapping in industrial electron beam radiation processing and outlines the challenges in delivering a uniform dose to cylindrical objects. In this study, HDPE pipe of 5 mm thickness of homogeneous material (40 mm outer diameter and 30 mm inner diameter) has been chosen for multi-sided irradiation under 2 MeV scanned electron beam from the ILU-6 accelerator. - Highlights: • The paper outlines the challenges in delivering uniform dose to cylindrical objects at 2 MeV industrial electron beam facility. • HDPE pipe of 40 mm outer diameter and 30 mm inner diameter has been chosen for the study. • The circumferential dose distribution inside and outside of the pipes were evaluated by using calibrated CTA dosimeter strips. • Using stack of dosimeter strips, changes in circumferential dose distribution in the annular region of the pipe was evaluated. • Optimization of multi-sided irradiation on the HDPE pipes for better dose homogeneity is reported in the paper.

  8. Dosimetric evaluation of multi-sided irradiation on HDPE pipes under 2 MeV electron beam

    International Nuclear Information System (INIS)

    Benny, P.G.; Khader, S.A.; Sarma, K.S.S.

    2014-01-01

    The use of electron beam technology has enabled the production of heat resistant pipe for hot water circulation. One of the difficulties in the irradiation of pipe products is the uneven penetration of electrons. Quality of the radiation process depends on radiation dose and homogeneity of the dose distribution, which becomes a major concern when treatments of circular objects like pipes are performed. One method to achieve uniformity in the absorbed dose in the product is to use multi-sided irradiation. The paper discusses the importance of dosimetry mapping in industrial electron beam radiation processing and outlines the challenges in delivering a uniform dose to cylindrical objects. In this study, HDPE pipe of 5 mm thickness of homogeneous material (40 mm outer diameter and 30 mm inner diameter) has been chosen for multi-sided irradiation under 2 MeV scanned electron beam from the ILU-6 accelerator. - Highlights: • The paper outlines the challenges in delivering uniform dose to cylindrical objects at 2 MeV industrial electron beam facility. • HDPE pipe of 40 mm outer diameter and 30 mm inner diameter has been chosen for the study. • The circumferential dose distribution inside and outside of the pipes were evaluated by using calibrated CTA dosimeter strips. • Using stack of dosimeter strips, changes in circumferential dose distribution in the annular region of the pipe was evaluated. • Optimization of multi-sided irradiation on the HDPE pipes for better dose homogeneity is reported in the paper

  9. The electron beam characteristics of energies up to 20 MeV and comparison of electron parameters of linear accelerators

    International Nuclear Information System (INIS)

    Awada, M.; Elleithy, M.A.; ElWihady, G.F.; Mostafa, K.A.

    2005-01-01

    The electron beams characteristics studded for the energies 4-20 MeV of Varian 23 EX ,experimental results are presented and compared with the published data. The CADD curves are measured for all energies and carried out the PDD of different applicator sizes ,that compared with the PDD of in the BJR. The quality beam parameters are determined from the CADD curves and calculated the yielded parameters of the corresponding electron energies which compared with the published data of other accelerators and theoretical Monte-Carlo calculation. The beam profiles are measured at different depths to construct the isodose distribution

  10. Control system for 10 MeV irradiation electron linac

    International Nuclear Information System (INIS)

    Zeng Ziqiang; Zhang Lifeng; Lu Weixing; Gao Zhenjiang; Zhang Yan; Han Guangwen; Wang Shuxian

    2005-01-01

    Control system of the 10 MeV electron linac using Distributed Control System (DCS) was studied. The hardware of control system consists of four SIEMENS PLCs and monitor computer, the software bases on STEP 7, Labwindows/CVI and SQL Server. The bus between the monitor computer and the main PLC is 100 M industrial networks, between PLCs is MPI bus, between PLC and remote partner is PROFIBUS, between PLC and terminals is RS485/422. The software of control system can provide a friendly human machine interface to operate the machine, protect the human and equipment from risk, and storage the status of the accelerator real time to the database. The monitor and maintenance of the linac can been carried out not only on local computer or local network, but also in internet. (author)

  11. Polarized electrons from GaAs for parity nonconservation studies and Moeller scattering at 250 MeV

    International Nuclear Information System (INIS)

    Cates, G.D. Jr.

    1987-01-01

    A description is given of a polarized electron source based on photoemission from GaAs with circularly polarized light, which was developed for use in the study of parity nonconservation (PNC) in e- 12 C scattering at 250 MeV at the MIT Bates Linear Accelerator Center. A multi-chamber vacuum system houses up to four GaAs crystals simultaneously, and is contained in a Faraday cage to provide 365 KeV in electrostatic acceleration. Stable operation is achieved through the use of a modulated cw laser. The PNC experiment is discussed, particularly with regards to its requirements on the source. The peak current from the source is 20 mA, resulting in a current in excess of 6 mA at high energy. The electron beam polarization has been measured to be 0.36 ± 0.004 using Moeller scattering at 250 MeV

  12. Analysis of thermionic DC electron gun for 125 MeV linac

    International Nuclear Information System (INIS)

    Kanno, K.; Sato, Isamu; Sato, K.

    2000-01-01

    The beam trace calculation for the 100 kV thermionic DC electron gun with EIMAC 646E cathode, which is currently used for the 125 MeV linac at Nihon University, has been performed using EGUN code. The result showed a strong focus of the beam at the exit of the anode. A better geometry of the gun has been investigated by varying the shape of the wehnelt electrode. Also the trace calculation has been performed for the case of EIMAC 646B, which showed a considerably small emittance compared with that estimated for the present gun. (author)

  13. Analysis of thermionic DC electron gun for 125 MeV linac

    Energy Technology Data Exchange (ETDEWEB)

    Kanno, K. [Graduate School of Science and Technology, Nihon Univ., Funabashi, Chiba (Japan); Sato, Isamu; Sato, K. [Nihon Univ., Funabashi, Chiba (Japan). Atomic Energy Research Inst] [and others

    2000-07-01

    The beam trace calculation for the 100 kV thermionic DC electron gun with EIMAC 646E cathode, which is currently used for the 125 MeV linac at Nihon University, has been performed using EGUN code. The result showed a strong focus of the beam at the exit of the anode. A better geometry of the gun has been investigated by varying the shape of the wehnelt electrode. Also the trace calculation has been performed for the case of EIMAC 646B, which showed a considerably small emittance compared with that estimated for the present gun. (author)

  14. Slowly moving test charge in two-electron component non-Maxwellian plasma

    International Nuclear Information System (INIS)

    Ali, S.; Eliasson, B.

    2015-01-01

    Potential distributions around a slowly moving test charge are calculated by taking into account the electron-acoustic waves in an unmagnetized plasma. Considering a neutralizing background of static positive ions, the supra-thermal hot and cold electrons are described by the Vlasov equations to account for the Kappa (power-law in velocity space) and Maxwell equilibrium distributions. Fourier analysis further leads to the derivation of electrostatic potential showing the impact of supra-thermal hot electrons. The test charge moves slowly in comparison with the hot and cold electron thermal speeds and is therefore shielded by the electrons. This gives rise to a short-range Debye-Hückel potential decaying exponentially with distance and to a far field potential decaying as inverse third power of the distance from the test charge. The results are relevant for both laboratory and space plasmas, where supra-thermal hot electrons with power-law distributions have been observed

  15. Monte Carlo 20 and 45 MeV Bremsstrahlung and dose-reduction calculations

    Energy Technology Data Exchange (ETDEWEB)

    Goosman, D.R.

    1984-08-14

    The SANDYL electron-photon coupled Monte Carlo code has been compared with previously published experimental bremsstrahlung data at 20.9 MeV electron energy. The code was then used to calculate forward-directed spectra, angular distributions and dose-reduction factors for three practical configurations. These are: 20 MeV electrons incident on 1 mm of W + 59 mm of Be, 45 MeV electrons of 1 mm of W and 45 MeV electrons on 1 mm of W + 147 mm of Be. The application of these results to flash radiography is discussed. 7 references, 12 figures, 1 table.

  16. Monte Carlo 20 and 45 MeV Bremsstrahlung and dose-reduction calculations

    International Nuclear Information System (INIS)

    Goosman, D.R.

    1984-01-01

    The SANDYL electron-photon coupled Monte Carlo code has been compared with previously published experimental bremsstrahlung data at 20.9 MeV electron energy. The code was then used to calculate forward-directed spectra, angular distributions and dose-reduction factors for three practical configurations. These are: 20 MeV electrons incident on 1 mm of W + 59 mm of Be, 45 MeV electrons of 1 mm of W and 45 MeV electrons on 1 mm of W + 147 mm of Be. The application of these results to flash radiography is discussed. 7 references, 12 figures, 1 table

  17. Feasibility study for mega-electron-volt electron beam tomography.

    Science.gov (United States)

    Hampel, U; Bärtling, Y; Hoppe, D; Kuksanov, N; Fadeev, S; Salimov, R

    2012-09-01

    Electron beam tomography is a promising imaging modality for the study of fast technical processes. But for many technical objects of interest x rays of several hundreds of keV energy are required to achieve sufficient material penetration. In this article we report on a feasibility study for fast electron beam computed tomography with a 1 MeV electron beam. The experimental setup comprises an electrostatic accelerator with beam optics, transmission target, and a single x-ray detector. We employed an inverse fan-beam tomography approach with radiographic projections being generated from the linearly moving x-ray source. Angular projections were obtained by rotating the object.

  18. Beam diagnostics using transition radiation produced by a 100 Mev electron beam

    International Nuclear Information System (INIS)

    Jablonka, M.; Leroy, J.; Hanus, X.; Derost, J.C.; Wartski, L.

    1991-01-01

    We report on several experiments using the optical transition radiation (OTR) produced by a 100 MeV electron beam. In using a sensitive video camera coupled with a digital image processing system an accurate and simple beam profile monitor has been devised. In measuring with a photo-multiplier the radiation emitted in a small solid angle around the direction of the OTR emission, a signal very sensitive to beam energy variations has been obtained. These experiments have been carried out on the Saclay ALS linac

  19. Numerical simulation of electrons dynamics in a microtron on 6 - 10 MeV

    Science.gov (United States)

    Bashmakov, Y. A.; Dyubkov, V. S.; Lozeev, Y. Y.

    2017-12-01

    Electron dynamics in 6.5 MeV classic microtron of the Lebedev Physics Institute (LPI) is investigated by means of numerical methods. Particular emphasis is placed on the formation mechanism of electron bunches at the first circular orbits. An effect of microtron main parameters such as accelerating RF field amplitude, DC magnetic field, as well as a geometry and a position of a thermal emitter on characteristics of electron beam extracted from the microtron are studied. In the space of mentioned parameters a region corresponding an optimal microtron operation mode is found. It is noted that the unique geometric and energy characteristics of accelerated beam makes use of microtron attractive not only as injector into a synchrotron, but also as a driver in experiments on generation of coherent terahertz electromagnetic radiation.

  20. Thermoluminescent response of LiF: Mg, Cu, P (GR-200) below an electron beam of 6 MeV

    International Nuclear Information System (INIS)

    Torijano C, E.F.S.; Azorin N, J.; Villasenor N, I.; Lujan C, P.J.; Rivera M, T.

    2007-01-01

    Full text: In this work the experimental results of studying the thermoluminescent response (TL) of LiF:Mg,Cu,P (GR-200) previously irradiated with 6 MeV electrons are presented. The electrons beam was generated by a Lineal Accelerator VARIAN I for medical use. The lineal accelerator is installed in the General Hospital of Mexico (HGM). A lot of 25 thermoluminescent dosemeters (DTL) was used. The mass and volume of each one of them were determined. Obtaining a variation of 14% in standard deviation (SD). The DTLs were irradiated to an energy of 6 MeV. The dose given to the DTL was of 50 c Gy. The linearity of the response of the GR-200 also was determined. (Author)

  1. Study on dynamics of beams of high luminosity in electron linacs

    International Nuclear Information System (INIS)

    Polyakov, V.A.; Shchedrin, I.S.

    1981-01-01

    To increase the electron beam luminosity in electron linacs (ELA), designed for electron microscopy, a numerical analysis of the electron dynamics in the ELA is carried out. Insufficiency of the available data on longitudinal beam motion in the 10 -4 -10 -5 relative energy spread on radial motion, as well as inadequacy of the data on aberrations of the second order introduced by the accelerating structure are shown. The necessary accountancy of the longitudinal Coulomb field is also shown. For the 1-10 MeV electron energies, 10 9 and 5x10 9 cm -3 bunch density, 5 deg-0.5 deg phase extension the beam current varies within the 0.2-10 mA. The bunch moves in the drift space of the 2.5 m length. The energy spread is 8x10 -8 (1 MeV) to 10 -4 (10 MeV) at the 2 mA beam current [ru

  2. Characterization and optimization of laser-driven electron and photon sources in keV and MeV energy ranges

    International Nuclear Information System (INIS)

    Bonnet, Thomas

    2013-01-01

    This work takes place in the framework of the characterization and the optimization of laser-driven electron and photon sources. With the goal of using these sources for nuclear physics experiments, we focused on 2 energy ranges: one around a few MeV and the other around a few tens of keV. The first part of this work is thus dedicated to the study of detectors routinely used for the characterization of laser-driven particle sources: Imaging Plates. A model has been developed and is fitted to experimental data. Response functions to electrons, photons, protons and alpha particles are established for SR, MS and TR Fuji Imaging Plates for energies ranging from a few keV to several MeV. The second part of this work present a study of ultrashort and intense electron and photon sources produced in the interaction of a laser with a solid or liquid target. An experiment was conducted at the ELFIE facility at LULI where beams of electrons and photons were accelerated up to several MeV. Energy and angular distributions of the electron and photons beams were characterized. The sources were optimized by varying the spatial extension of the plasma at both the front and the back end of the initial target position. In the optimal configuration of the laser-plasma coupling, more than 1011 electrons were accelerated. In the case of liquid target, a photon source was produced at a high repetition rate on an energy range of tens of keV by the interaction of the AURORE Laser at CELIA (10 16 W.cm -2 ) and a melted gallium target. It was shown that both the mean energy and the photon number can be increased by creating gallium jets at the surface of the liquid target with a pre-pulse. A physical interpretation supported by numerical simulations is proposed. (author)

  3. The study of 1 MeV electron irradiation induced defects in N-type and P-type monocrystalline silicon

    Science.gov (United States)

    Babaee, S.; Ghozati, S. B.

    2017-12-01

    Despite extensive use of GaAs cells in space, silicon cells are still being used. The reason is that not only they provide a good compromise between efficiency and cost, but also some countries do not have the required technology for manufacturing GaAs. Behavior of a silicon cell under any levels of charged particle irradiation could be deducted from the results of a damage equivalent 1 MeV electron irradiation using the NASA EQflux open source software package. In this paper for the first time, we have studied the behavior of a silicon cell before and after 1 MeV electron irradiation with 1014, 1015 and 1016 electrons-cm-2 fluences, using SILVACO TCAD simulation software package. Simulation was carried out at room temperature under AM0 condition. Results reveal that open circuit voltage and efficiency decrease after irradiation while short circuit current shows a slight increase in the trend around 5 × 1016 electrons-cm-2, and short circuit current loss plays an important role on efficiency changes rather than open circuit voltage.

  4. A moving target for accelerated charged particle induced X-ray measurement

    International Nuclear Information System (INIS)

    Chuang, L.S.; Shima, K.; Ebihara, H.; Seki, R.; Mikumo, T.

    1980-01-01

    To attain good reproducibility as well as to enable an absolute determination in the measurement of X-ray fluorescences, resulting from bombardment of a heterogeneous sample by accelerated charged particles, a moving-target mechanism incorporating an electronic remote control system has been devised. The system is designed to scan the whole sample area with a chosen constant linear speed, by a fixed particle beam with a cross-sectional area a small fraction of that of the sample. Using 16 MeV protons and 40 MeV oxygen-ion beams, test runs of this system showed that the attempted objectives are attainable with good accuracies: reproducibility of the data for a given target is better than 3%, the linearity of the calibration curve is in good agreement, within the weighing errors of the standard elements and the uncertainty due to beam current fluctuation, with the expected values, and the results of absolute determinations using both metal foils and heterogeneous powder samples are in good agreement with accepted results using different methods. Detailed accounts of the moving-target system, and the test for reproducibility and linearity are presented. An absolute determination of the quantities related to accelerated charged-particle induced X-ray fluorescence (PIXE) using the moving target is presented for samples in different forms. (orig./HP)

  5. Physics design of a 10 MeV, 6 kW travelling wave electron linac for ...

    Indian Academy of Sciences (India)

    2016-10-11

    Oct 11, 2016 ... We present the physics design of a 10 MeV, 6 kW S-band (2856 MHz) electron linear ... linac (in contrast with standing wave linac) is that it accepts the RF power over a band of frequencies. Three- ... structures are preferred for relatively higher energy ... klystron in a TW linac, which results in cost reduction.

  6. Comparative time-series analysis of MeV electron data by Ulysses and Pioneer 10/11 in the Jovian magnetosphere

    International Nuclear Information System (INIS)

    Dunzlaff, P.; Kiel Univ.; Heber, B.; Kopp, A.; North-West Univ., Potchefstroom; Potgieter, M.S.

    2013-01-01

    The dynamics of the Jovian magnetosphere is dominated by the planet's fast rotation with a period of ∝ 10 h.Within the magnetosphere, this periodicity can in particular be seen in the temporal variation of the spectral index of MeV electrons: every ∝ 10 h the counting rates show a maximum (minimum), while the spectral index shows a minimum (maximum) known as the Jovian ''clock'' mechanism. In this study we re-analyse Ulysses and Pioneer 10/11 data and show that another periodic modulation in the MeV electrons can be identified, manifested by local maxima of the spectral index and local minima of the counting rates. For Ulysses, this modulation can be observed throughout the magnetosphere near the magnetic equator, suggesting an azimuthal asymmetric distribution of MeV electrons near the current sheet. This modulation is found to trail the ''clock'' mechanism by ∝ 3.25 h. The Pioneer 10 data, however, only show occasional evidence of the presence of these local maxima while there is no evidence of this modulation in the Pioneer 11 data. A comparison of the times of observed minor peaks and Ulysses' distance from the current sheet using a simple rigid disc model as well as the model of Khurana and Schwarzl (2005) is performed.

  7. High power pulsed/microwave technologies for electron accelerators vis a vis 10MeV, 10kW electron LINAC for food irradiation at CAT

    International Nuclear Information System (INIS)

    Shrivastava, Purushottam; Mulchandani, J.; Mohania, P.; Baxy, D.; Wanmode, Y.; Hannurkar, P.R.

    2005-01-01

    Use of electron accelerators for irradiation of food items is gathering momentum in India. The various technologies for powering the electron LINAC were needed to be developed in the country due to embargo situations as well as reservations of the developers worldwide to share the information related to this development. Centre for Advanced Technology, CAT, Indore, is engaged in the development of particle accelerators for medical industrial and scientific applications. Amongst other electron accelerators developed in CAT, a 10MeV, 10kW LINAC for irradiation of food items has been commissioned and tested for full rated 10kW beam power. The high power pulsed microwave driver for the LINAC was designed, developed and commissioned with full indigenous efforts, and is right now operational at CAT. It consists of a 6MW, 25kW S-band pulsed klystron, 15MW peak power pulse modulator system for the klystron, microwave driver amplifier chain, stabilized generator, protection and control electronics, waveguide system to handle the high peak and average power, gun modulator electronics, grid electronics etc. The present paper highlights various technologies like the pulsed power systems and components, microwave circuits and systems etc. Also the performance results of the high power microwave driver for the 10MeV LINAC at CAT are discussed. Future strategies for developing the state of art technologies are highlighted. (author)

  8. Free electron laser facilities employing a 150-MeV linac injector for Saga synchrotron light source

    International Nuclear Information System (INIS)

    Tomimasu, T.; Yasumoto, M.; Ochiai, Y.; Ishibashi, M.; Murayama, T.

    1999-01-01

    Free electron laser (FEL) facilities as the FELI FEL Facility are proposed, for which a 150-MeV linac type injector for a Saga synchrotron light source (SLS) is employed in FEL mode. The linac has two operating modes; short macropulse mode a 1 μs at 150 MeV for injection to a 1 - 1.3-GeV third generation type storage ring and long macropulse mode of 12 μs at 100 MeV for four FEL Facilities. The macropulse beam consists of a train of several ps, 0.6 nC microbunches (peak current 100 A) repeating at 89.25 MHz. We are aiming to supply high power level photon beams covering an attractive wavelength range from 0.05 nm (25 keV) to 200 μm (0.006 eV) for scientific researches, bio-medical and industrial applications, using the Saga third generation type SLS with a superconducting wiggler and the proposed four FEL Facilities. (author)

  9. Angular distributions of relativistic electrons under channeling in half-wavelength crystal and corresponding radiation

    International Nuclear Information System (INIS)

    Takabayashi, Y.; Bagrov, V.G.; Bogdanov, O.V.; Pivovarov, Yu.L.; Tukhfatullin, T.A.

    2015-01-01

    New experiments on channeling of 255 MeV electrons in a half-wavelength crystals (HWC) were performed at SAGA Light Source facilities. The simulations of trajectories for (2 2 0) and (1 1 1) planar channeling in Si were performed using the computer code BCM-1.0. Comparison of experimental and theoretical results shows a good agreement. The results of calculations of spectral distribution of radiation in forward direction (θ = 0°) from 255 MeV electrons at (2 2 0) channeling in HWC silicon are presented. Qualitative comparison with radiation spectrum from an electron moving in an arc is performed

  10. Preliminary examination of induced radioactivity in pepper by 10 MeV electron irradiation

    International Nuclear Information System (INIS)

    Katayama, Tadashi; Furuta, Masakazu; Sibata, Setsuko; Ito, Norio; Mizohata, Akira; Matsunami, Tadao; Toratani, Hirokazu; Takeda, Atsuhiko.

    1991-01-01

    β-ray measurement was performed on 10 MeV electron-irradiated black pepper and white pepper with liquid scintillation counter in order to reconfirm the wholesomeness of irradiated foods and present unambiguous data to general consumers concerning about the induced radioactivity in the irradiated foods. In irradiated black pepper no radioactivity other than from natural source, un-irradiated one, was detected. But in irradiated white pepper, it was suggested that induced radioactivity might be detected if the detection method was more improved. (author)

  11. CESAR, 2 MeV electron storage ring; general view from above.

    CERN Multimedia

    Service Photo; CERN PhotoLab

    1967-01-01

    CESAR (CERN Electron Storage and Accumulation Ring) was built as a study-model for the ISR (Intersecting Storage Rings). The model had to be small (24 m circumference) and yet the particles had to be highly relativistic, which led to the choice of electrons. On the other hand, in order to model the behaviour of protons, effects from synchrotron radiation had to be negligible, which meant low magnetic fields (130 G in the bending magnets) and a corresponding low energy of 1.75 MeV. All the stacking (accumulation) procedures envisaged for the ISR were proven with CESAR, and critical aspects of transverse stability were explored. Very importantly, CESAR was the test-bed for the ultrahigh vacuum techniques and components, essential for the ISR, with a final pressure of 6E-11 Torr. The CESAR project was decided early in 1960, design was completed in 1961 and construction in 1963. After an experimental period from 1964 to 1967, CESAR was dismantled in 1968.

  12. High-resolution Auger spectroscopy on 79 MeV Ar5+, 89 MeV Ar6+, and 136 MeV Ar7+ ions after excitation by helium

    International Nuclear Information System (INIS)

    Schneider, T.

    1988-01-01

    In this thesis the atomic structure of highly excited Ar 6+ and Ar 7+ ions was studied. For this 79 MeV Ar 5+ , 89 MeV Ar 6+ , and 136 MeV Ar 7+ ions of a heavy ion accelerator were excited by a He gas target to autoionizing states and the Auger electrons emitted in the decay were measured in highly-resolving state. The spectra were taken under an observational angle of zero degree relative to the beam axis in order to minimize the kinematical broadening of the Auger lines. (orig./HSI) [de

  13. Estimation of Electron Dose Delivered by a 0.4 MeV Accelerator from Bremsstrahlung Dose Measurements

    DEFF Research Database (Denmark)

    Karadjov, A. G.; Hansen, Jørgen-Walther

    1980-01-01

    Determination of a 0.4 MeV electron dose from a bremsstrahlung dose measurement using a converter-detector system is considered. The detector used is a Frickle dosimeter, and the converters are aluminum, copper and lead foils. Optimal converter thickness is ascertained experimentally for each mat...... materials within a Z-range of 13–82. A linear relation is found between bremsstrahlung dose and electron dose ranging from 2 to 20 Mrad. Finally the effect of converter area on detector response is studied....

  14. Absolute Calibration of Image Plate for electrons at energy between 100 keV and 4 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Chen, H; Back, N L; Eder, D C; Ping, Y; Song, P M; Throop, A

    2007-12-10

    The authors measured the absolute response of image plate (Fuji BAS SR2040) for electrons at energies between 100 keV to 4 MeV using an electron spectrometer. The electron source was produced from a short pulse laser irradiated on the solid density targets. This paper presents the calibration results of image plate Photon Stimulated Luminescence PSL per electrons at this energy range. The Monte Carlo radiation transport code MCNPX results are also presented for three representative incident angles onto the image plates and corresponding electron energies depositions at these angles. These provide a complete set of tools that allows extraction of the absolute calibration to other spectrometer setting at this electron energy range.

  15. Electron and ion currents relevant to accurate current integration in MeV ion backscattering spectrometry

    International Nuclear Information System (INIS)

    Matteson, S.; Nicolet, M.A.

    1979-01-01

    The magnitude and characteristics of the currents which flow in the target and the chamber of an MeV ion backscattering spectrometer are examined. Measured energy distributions and the magnitude of high-energy secondary electron currents are reported. An empirical universal curve is shown to fit the energy distribution of secondary electrons for several combinations of ion energy, targets and ion species. The magnitude of tertiary electron currents which arise at the vacuum vessel walls is determined for various experimental situations and is shown to be non-negligible in many cases. An experimental arrangement is described which permits charge integrations to 1% arruracy without restricting access to the target as a Faraday cage does. (Auth.)

  16. Characterization of a power bipolar transistor as high-dose dosimeter for 1.9-2.2 MeV electron beams

    Energy Technology Data Exchange (ETDEWEB)

    Fuochi, P.G., E-mail: fuochi@isof.cnr.i [ISOF-CNR Institute, Via P. Gobetti 101, I-40129, Bologna (Italy); Lavalle, M.; Corda, U. [ISOF-CNR Institute, Via P. Gobetti 101, I-40129, Bologna (Italy); Kuntz, F.; Plumeri, S. [Aerial, Parc d' Innovation Rue Laurent Fries F-67400 Illkirch (France); Gombia, E. [IMEM-CNR Institute, Viale delle Scienze 37 A, Loc. Fontanini, 43010 Parma (Italy)

    2010-04-15

    Results of the characterization studies on a power bipolar transistor investigated as a possible radiation dosimeter under laboratory condition using electron beams of energies from 2.2 to 8.6 MeV and gamma rays from a {sup 60}Co source and tested in industrial irradiation plants having high-activity {sup 60}Co gamma-source and high-energy, high-power electron beam have previously been reported. The present paper describes recent studies performed on this type of bipolar transistor irradiated with 1.9 and 2.2 MeV electron beams in the dose range 5-50 kGy. Dose response, post-irradiation heat treatment and stability, effects of temperature during irradiation in the range from -104 to +22 deg. C, dependence on temperature during reading in the range 20-50 deg. C, and the difference in response of the transistors irradiated from the plastic side and the copper side are reported. DLTS measurements performed on the irradiated devices to identify the recombination centres introduced by radiation and their dependence on dose and energy of the electron beam are also reported.

  17. Electron-lattice energy relaxation in laser-excited thin-film Au-insulator heterostructures studied by ultrafast MeV electron diffraction.

    Science.gov (United States)

    Sokolowski-Tinten, K; Shen, X; Zheng, Q; Chase, T; Coffee, R; Jerman, M; Li, R K; Ligges, M; Makasyuk, I; Mo, M; Reid, A H; Rethfeld, B; Vecchione, T; Weathersby, S P; Dürr, H A; Wang, X J

    2017-09-01

    We apply time-resolved MeV electron diffraction to study the electron-lattice energy relaxation in thin film Au-insulator heterostructures. Through precise measurements of the transient Debye-Waller-factor, the mean-square atomic displacement is directly determined, which allows to quantitatively follow the temporal evolution of the lattice temperature after short pulse laser excitation. Data obtained over an extended range of laser fluences reveal an increased relaxation rate when the film thickness is reduced or the Au-film is capped with an additional insulator top-layer. This behavior is attributed to a cross-interfacial coupling of excited electrons in the Au film to phonons in the adjacent insulator layer(s). Analysis of the data using the two-temperature-model taking explicitly into account the additional energy loss at the interface(s) allows to deduce the relative strength of the two relaxation channels.

  18. Secondary electron emission from metals irradiated by 0.4-3 MeV gamma-quanta

    International Nuclear Information System (INIS)

    Grudskij, M.Ya.; Malyshenkov, A.V.; Smirnov, V.V.

    1975-01-01

    Experimental and calculational data were considered on the secondary electron emission outgoing from metal targets of an equilibrium thickness irradiated by gamma-quanta fluxes with the energies from 0.4 to 3 MeV. New experimental data are presented. Characteristics of emission were measured by two methods: by magnetic spectrometers with a transverse magnetic field, and by means of an electrometric device with using radioisotopic gamma-sources of 198 Au, 137 Cs, 60 Co and 24 Na. The dependence of the electron emission on the atomic number of the target material was studied. For this purpose the parameters of emissions outgoing from Al-, Cu-, Cd-, Pb- and Au-targets were measured. The advantages and shortcomings of the known methods of calculating the second electron emission were discussed. The obtained experimental and calculational results on studying electrons were compared with those known from literature, and possible sources of systematic errors were discussed

  19. Comparative time-series analysis of MeV electron data by Ulysses and Pioneer 10/11 in the Jovian magnetosphere

    Energy Technology Data Exchange (ETDEWEB)

    Dunzlaff, P. [North-West Univ., Potchefstroom (South Africa). Centre for Space Research; Kiel Univ. (Germany). Inst. fuer Experimentelle und Angewandte Physik; Heber, B. [Kiel Univ. (Germany). Inst. fuer Experimentelle und Angewandte Physik; Kopp, A. [Kiel Univ. (Germany). Inst. fuer Experimentelle und Angewandte Physik; North-West Univ., Potchefstroom (South Africa). Centre for Space Research; Potgieter, M.S. [North-West Univ., Potchefstroom (South Africa). Centre for Space Research

    2013-11-01

    The dynamics of the Jovian magnetosphere is dominated by the planet's fast rotation with a period of {proportional_to} 10 h.Within the magnetosphere, this periodicity can in particular be seen in the temporal variation of the spectral index of MeV electrons: every {proportional_to} 10 h the counting rates show a maximum (minimum), while the spectral index shows a minimum (maximum) known as the Jovian ''clock'' mechanism. In this study we re-analyse Ulysses and Pioneer 10/11 data and show that another periodic modulation in the MeV electrons can be identified, manifested by local maxima of the spectral index and local minima of the counting rates. For Ulysses, this modulation can be observed throughout the magnetosphere near the magnetic equator, suggesting an azimuthal asymmetric distribution of MeV electrons near the current sheet. This modulation is found to trail the ''clock'' mechanism by {proportional_to} 3.25 h. The Pioneer 10 data, however, only show occasional evidence of the presence of these local maxima while there is no evidence of this modulation in the Pioneer 11 data. A comparison of the times of observed minor peaks and Ulysses' distance from the current sheet using a simple rigid disc model as well as the model of Khurana and Schwarzl (2005) is performed.

  20. Low energy spread 100 MeV-1 GeV electron bunches from laser wakefield acceleration at LOASIS

    International Nuclear Information System (INIS)

    Geddes, C.G.R.; Esarey, E.; Michel, P.; Nagler, B.; Nakamura, K.; Plateau, G.R.; Schroeder, C.B.; Shadwick, B.A.; Toth, Cs.; Van Tilborg, J.; Leemans, W.P.; Hooker, S.M.; Gonsalves, A.J.; Michel, E.; Cary, J.R.; Bruhwiler, D.

    2006-01-01

    Experiments at the LOASIS laboratory of LBNL recently demonstrated production of 100 MeV electron beams with low energy spread and low divergence from laser wakefield acceleration. The radiation pressure of a 10 TW laser pulse guided over 10 diffraction ranges by a plasma density channel was used to drive an intense plasma wave (wakefield), producing acceleration gradients on the order of 100 GV/m in a mm-scale channel. Beam energy has now been increased from 100 to 1000 MeV by using a cm-scale guiding channel at lower density, driven by a 40TW laser, demonstrating the anticipated scaling to higher beam energies. Particle simulations indicate that the low energy spread beams were produced from self trapped electrons through the interplay of trapping, loading, and dephasing. Other experiments and simulations are also underway to control injection of particles into the wake, and hence improve beam quality and stability further

  1. Bunch evolution study in optimization of MeV ultrafast electron diffraction

    International Nuclear Information System (INIS)

    Lu Xianhai; Du Yingchao; Huang Wenhui; Tang Chuanxiang

    2014-01-01

    transverse ultrafast electron diffraction (UED) is a promising detection tool for ultrafast processes. The quality of diffraction image is determined by the transverse evolution of the probe bunch. In this paper, we study the contributing terms of the emittance and space charge effects to the bunch evolution in the MeV UED scheme, employing a mean-field model with an ellipsoidal distribution as well as particle tracking simulation. The small transverse dimension of the drive laser is found to be critical to improve the reciprocal resolution, exploiting both smaller emittance and larger transverse bunch size before the solenoid. The degradation of the reciprocal spatial resolution caused by the space charge effects should be carefully controlled. (authors)

  2. Bunch evolution study in optimization of MeV ultrafast electron diffraction

    Science.gov (United States)

    Lu, Xian-Hai; Du, Ying-Chao; Huang, Wen-Hui; Tang, Chuan-Xiang

    2014-12-01

    Megaelectronvolt ultrafast electron diffraction (UED) is a promising detection tool for ultrafast processes. The quality of diffraction image is determined by the transverse evolution of the probe bunch. In this paper, we study the contributing terms of the emittance and space charge effects to the bunch evolution in the MeV UED scheme, employing a mean-field model with an ellipsoidal distribution as well as particle tracking simulation. The small transverse dimension of the drive laser is found to be critical to improve the reciprocal resolution, exploiting both smaller emittance and larger transverse bunch size before the solenoid. The degradation of the reciprocal spatial resolution caused by the space charge effects should be carefully controlled.

  3. Design and simulation of a 1.2MeV electron accelerator used for desulfuration and denitrogenation

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, J.; Zhu, D.J.; Liu, S.G.; Wang, H.B.; Xu, Z.; Liu, X.S. [University of Electrical Science & Technology of China, Chengdu (China)

    2005-07-01

    This paper presents the structural design and functional analysis of a new kind of 1.2MeV industrial electron accelerator. PIC (Particle-In-Cell) method is used to simulate this accelerator and to optimize the design. The results show that the optics property of this accelerator has been improved. This electron accelerator is used for desulfurisation and denitrification in environmental industry. This application purifies flue gases of the thermal power stations from sulphur oxide and nitrogen oxides in order to reduce air pollution.

  4. Electron angular distributions in He single ionization impact by H2+ ions at 1 MeV

    International Nuclear Information System (INIS)

    Zhang Shaofeng; Ma Xinwen; Suske, J; Fischer, D; Kuehnel, K U; Voitkiv, A; Najjaril, B; Krauss, A; Moshammer, R; Ullrich, J; Hagmann, S

    2009-01-01

    For the first time we investigated in a kinematically complete experiment the ionization of helium in collisions with H 2 + -molecular ions at 1 MeV. Using two separate detectors, the orientation of the projectile H 2 + -molecular ions was determined at the instance of the collision. The electron angular distribution was measured by a R eaction Microscope . The observed structures are found in agreement with theoretical calculations, indicating that the ionized electron of He shows a slight preferential emission direction parallel to the molecular axis.

  5. Orientational acoustic emission induced by electrons moving near a crystallographic axis in tungsten

    International Nuclear Information System (INIS)

    Alejnik, A.N.; Vorob'ev, S.A.; Zabaev, V.N.; Il'in, S.I.; Kalinin, B.N.; Potylitsyn, A.P.

    1988-01-01

    The measurement results of oriented acoustic irradiation of electrons with E 0 =900 MeV energies during their axial (along the direction) motion in tungsten monocrystal of 0.29 mm thickness are presented. The model describing the excitation of elastic waves in crystals as the consequence of the momentum transferred to the crystal by electrons during their motion near the axis is suggested. The model describes quite fully main laws of oriented acoustic irradiation. It permits to receive the information about the potential of the atom chain

  6. Confinement of 2,4 MeV deuterons by plasmoids and focalization of electron beams in plasma focus discharges

    International Nuclear Information System (INIS)

    Nardi, V.; Bostick, W.; Prior, W.; Feugeas, J.; Bortolotti, A.

    1982-01-01

    A detailed analysis has been completed on the internal structure of ions and electron beams which are efected, along the system axis, in opposite directions (0 0 and 180 0 ). An image (contact print) of plasmoids which emit MeV deuterons is formed by the deuteron emission and it is revealed by etching deuteron tracks in a target of plastic material (CR-39). Ion-imaging with different energy filters discriminates between tracks of plasmoid ions and tracks of charged products of D-D fusion reactions. Ions-imaging can also discriminate plasmoid deuterons from MeV deuterons of a directed beam. (L.C.) [pt

  7. Shielding Calculations for Industrial 5/7.5MeV Electron Accelerators Using the MCNP Monte Carlo Code

    International Nuclear Information System (INIS)

    Peri, E.; Orion, I.

    2014-01-01

    High energy X-rays from accelerators are used to irradiate food ingredients to prevent growth and development of unwanted biological organisms in food, in order to extend the shelf life of products. High energy photons can cause food activation due to (D 3 ,n) reactions. Until 2004, to eliminate the possibility of food activation, the electron energy was limited to 5 MeV X-rays for food irradiation. In 2004, the FDA approved the usage of up to 7.5 MeV, but only with tantalum and gold targets (1). Higher X-ray energy results an increased flux of X-rays in the forward direction, increased penetration, and higher photon dose rate due to better electron-to-photon conversion. These improvements could decrease the irradiation time and allow irradiation of larger packages, thereby providing higher production rates with lower treatment cost. Medical accelerators usually work with 6-18 MV electron energy with tungsten target to convert the electron beam to X-rays. In order to protect the patients, the accelerator head is protected with a heavy lead shielding; therefore, the bremsstrahlung is emitted only in the forward direction. There are many publications and standards that guide how to design optimal shielding for medical accelerator rooms. The shielding data for medical accelerators is not applicable for industrial accelerators, since the data is for different conversion targets, different X-Ray energies, and only for the forward direction. Collimators are not always in use in industrial accelerators, and therefore bremsstrahlung photons can be emitted in all directions. The bremsstrahlung spectrum and dose rate change as a function of the emission angle. The dose rate decreases from maximum in the forward direction (0°) to minimum at 180° by 1-2 orders of magnitude. In order to design and calculate optimal shielding for food accelerator rooms, there is a need to have the bremsstrahlung spectrum data, dose rates and concrete attenuation data in all emission directions

  8. Design and simulation of a 1.2 MeV electron accelerator used for desulfuration and denitrogenation

    International Nuclear Information System (INIS)

    Zhou Jun; Zhu Dajun; Liu Shenggang

    2005-01-01

    This paper presents the structural design and functional analysis of a new kind of 1.2 MeV industrial electron accelerator. PIC (Particle-In-Cell) method is used to simulate this accelerator and to optimize the design, the results show that the optics property of this accelerator has been improved. This electron accelerator is used for desulfuration and denitrogenation in environmental industry. This application purifies flue gases of the thermal power station from Sulphurous oxide and Nitrogen oxide in order to reduce the pollution in the air. (author)

  9. Injection of a single electron from static to moving quantum dots.

    Science.gov (United States)

    Bertrand, Benoit; Hermelin, Sylvain; Mortemousque, Pierre-André; Takada, Shintaro; Yamamoto, Michihisa; Tarucha, Seigo; Ludwig, Arne; Wieck, Andreas D; Bäuerle, Christopher; Meunier, Tristan

    2016-05-27

    We study the injection mechanism of a single electron from a static quantum dot into a moving quantum dot. The moving quantum dots are created with surface acoustic waves (SAWs) in a long depleted channel. We demonstrate that the injection process is characterized by an activation law with a threshold that depends on the SAW amplitude and on the dot-channel potential gradient. By sufficiently increasing the SAW modulation amplitude, we can reach a regime where the transfer has unity probability and is potentially adiabatic. This study points to the relevant regime to use moving dots in quantum information protocols.

  10. Product conveying system for 10 MeV electron beam accelerator for electron beam centre, Kharghar, Navi Mumbai

    International Nuclear Information System (INIS)

    Bandi, L.N.; Lavale, D.S.; Sarma, K.S.S.; Khader, S.A.; Assadullah, M.; Sabharwal, S.

    2003-01-01

    In industrial radiation processing applications using accelerators, product conveying system plays a vital role in exposing the product to high energy electron beam for imparting specified dose to the product and delivering required through puts. The speed of the conveyor corresponds to a definite time of exposure of the product in the radiation zone. Design of suitable conveyor system for a variety of products with differing dose requirements call for a conveyor with wide speed range. This paper discusses the design features of a suitable under beam conveyor system for 10 MeV, 10 kW accelerator for processing a range of products including medical and food products

  11. High efficiency charge recuperation for electron beams of MeV energies

    International Nuclear Information System (INIS)

    MacLachlan, J.A.

    1996-05-01

    Electron cooling of ion beams with energies of some GeV per nucleon requires high-quality electron beams of MeV energies and currents as high as several amperes. The enormous beam power dictates that the beam current be returned to the high voltage terminal which provides the accelerating potential. The beam is returned to a carefully designed collector within the terminal and biased a few kV positive with respect to it. Thus the load on the HV supply is only the accelerating potential times the sum of the beam current loss and the current used to maintain a graded potential on the accelerating structure. If one employs an electrostatic HV supply like a Van de Graaff with maximum charging current of a few hundred microA, the permissible fractional loss is ∼ 10 -4 . During the 15 years or so the concept of medium energy electron cooling has been evolving, the need to demonstrate the practicability of such high efficiency beam recovery has been recognized. This paper will review some experimental tests and further experiments which have been proposed. The design and status are presented for a new re-circulation experiment at 2 MV being carried out by Fermilab at National Electrostatics Corp

  12. Ultra high vacuum system of the 3 MeV electron beam accelerator

    International Nuclear Information System (INIS)

    Puthran, G.P.; Jayaprakash, D.; Mishra, R.L.; Ghodke, S.R.; Majumder, R.; Mittal, K.C.; Sethi, R.C.

    2003-01-01

    Full text: A 3 MeV electron beam accelerator is coming up at the electron beam centre, Kharghar, Navi Mumbai. A vacuum of the order of 1x10 -7 mbar is desired in the beam line of the accelerator. The UHV system is spread over a height of 6 meters. The total surface area exposed to vacuum is 65,000 cm 2 and the volume is 200 litres. Distributed pumping is planned, to avoid undesirable vacuum gradient between any two sections of the beam-line. The electron beam is scanned in an area of 6 cms x 100 cms and it comes out of the scan-horn through a titanium foil of 50 micron thick. Hence the vacuum system is designed in such a way that, in the event of foil rupture during beam extraction, the electron gun, accelerating column and the pumps can be protected from sudden air rush. The vacuum in the beam-line can also be maintained in this condition. After changing the foil, scan-horn area can be separately pumped to bring the vacuum level as desired and can be opened to the beam-line. The design, vacuum pumping scheme and the safety aspects are discussed in this paper

  13. Production and aging of paramagnetic point defects in P-doped floating zone silicon irradiated with high fluence 27 MeV electrons

    Science.gov (United States)

    Joita, A. C.; Nistor, S. V.

    2018-04-01

    Enhancing the long term stable performance of silicon detectors used for monitoring the position and flux of the particle beams in high energy physics experiments requires a better knowledge of the nature, stability, and transformation properties of the radiation defects created over the operation time. We report the results of an electron spin resonance investigation in the nature, transformation, and long term stability of the irradiation paramagnetic point defects (IPPDs) produced by high fluence (2 × 1016 cm-2), high energy (27 MeV) electrons in n-type, P-doped standard floating zone silicon. We found out that both freshly irradiated and aged (i.e., stored after irradiation for 3.5 years at 250 K) samples mainly contain negatively charged tetravacancy and pentavacancy defects in the first case and tetravacancy defects in the second one. The fact that such small cluster vacancy defects have not been observed by irradiation with low energy (below 5 MeV) electrons, but were abundantly produced by irradiation with neutrons, strongly suggests the presence of the same mechanism of direct formation of small vacancy clusters by irradiation with neutrons and high energy, high fluence electrons, in agreement with theoretical predictions. Differences in the nature and annealing properties of the IPPDs observed between the 27 MeV electrons freshly irradiated, and irradiated and aged samples were attributed to the presence of a high concentration of divacancies in the freshly irradiated samples, defects which transform during storage at 250 K through diffusion and recombination processes.

  14. Physics design of a 10 MeV, 6 kW travelling wave electron linac for industrial applications

    International Nuclear Information System (INIS)

    Kulkarni, Nita S.; Dhingra, Rinky; Kumar, Vinit

    2016-01-01

    We present the physics design of a 10 MeV, 6 kW S-band (2856 MHz) electron linear accelerator (linac), which has been recently built and successfully operated at Raja Ramanna Centre for Advanced Technology, Indore. The accelerating structure is a 2π/3 mode constant impedance travelling wave structure, which comprises travelling wave buncher cells, followed by regular accelerating cells. The structure is designed to accelerate 50 keV electron beam from the electron gun to 10 MeV. This paper describes the details of electromagnetic design simulations to fix the mechanical dimensions and tolerances, as well as heat loss calculations in the structure. Results of design simulations have been compared with those obtained using approximate analytical formulae. The beam dynamics simulation with space charge is performed and the required magnetic field profile for keeping the beam focussed in the linac has been evaluated and discussed. An important feature of a travelling wave linac (in contrast with standing wave linac) is that it accepts the RF power over a band of frequencies. Three dimensional transient simulations of the accelerating structure along with the input and output couplers have been performed using the software CST-MWS to explicitly demonstrate this feature. (author)

  15. Test calculations of photoneutrons emission from surface of uranium sphere irradiated by 28 MeV electrons

    International Nuclear Information System (INIS)

    Blokhin, A.I.; Degtyarev, I.I.

    2002-01-01

    In this paper the results of physical verification for the BOFOD photonuclear data files are reported, available for the uranium isotopes U 235 , U 238 . These results were compared with calculated data by the parameterization driven model of photonuclear reaction and experimental data. Experimental data of photoneutron yields from surface of uranium sphere irradiated by 28 MeV electrons are used for a verification. Both calculations have been carried out with the RTS and T general purpose Monte Carlo code with detailed electron-photon-nucleon transport simulation using the ENDF/B-VI and EPDL evaluated data libraries

  16. Comparison of GATE/GEANT4 with EGSnrc and MCNP for electron dose calculations at energies between 15 keV and 20 MeV.

    Science.gov (United States)

    Maigne, L; Perrot, Y; Schaart, D R; Donnarieix, D; Breton, V

    2011-02-07

    The GATE Monte Carlo simulation platform based on the GEANT4 toolkit has come into widespread use for simulating positron emission tomography (PET) and single photon emission computed tomography (SPECT) imaging devices. Here, we explore its use for calculating electron dose distributions in water. Mono-energetic electron dose point kernels and pencil beam kernels in water are calculated for different energies between 15 keV and 20 MeV by means of GATE 6.0, which makes use of the GEANT4 version 9.2 Standard Electromagnetic Physics Package. The results are compared to the well-validated codes EGSnrc and MCNP4C. It is shown that recent improvements made to the GEANT4/GATE software result in significantly better agreement with the other codes. We furthermore illustrate several issues of general interest to GATE and GEANT4 users who wish to perform accurate simulations involving electrons. Provided that the electron step size is sufficiently restricted, GATE 6.0 and EGSnrc dose point kernels are shown to agree to within less than 3% of the maximum dose between 50 keV and 4 MeV, while pencil beam kernels are found to agree to within less than 4% of the maximum dose between 15 keV and 20 MeV.

  17. MeV Mott polarimetry at Jefferson Lab

    International Nuclear Information System (INIS)

    Steigerwald, M.

    2001-01-01

    In the recent past, Mott polarimetry has been employed only at low electron beam energies (≅100 keV). Shortly after J. Sromicki demonstrated the first Mott scattering experiment on lead foils at 14 MeV (MAMI, 1994), a high energy Mott scattering polarimeter was developed at Thomas Jefferson National Accelerator Facility (5 MeV, 1995). An instrumental precision of 0.5% was achieved due to dramatic improvement in eliminating the background signal by means of collimation, shielding, time of flight and coincidence methods. Measurements for gold targets between 0.05 μm and 5 μm for electron energies between 2 and 8 MeV are presented. A model was developed to explain the depolarization effects in the target foils due to double scattering. The instrumental helicity correlated asymmetries were measured to smaller than 0.1%

  18. Radiative interaction of electrons in a short electron bunch moving in an undulator

    International Nuclear Information System (INIS)

    Saldin, E. L.; Schneidmiller, E. A.; Yurkov, M. V.

    1999-01-01

    This paper presents investigations of the longitudinal radiative force in an electron bunch. The model of the electron bunch assumes line density distribution. General formulas are presented for the calculation of the radiative force in the bunch moving along an arbitrary small-angle trajectory. The case of a motion in an undulator (wiggler) has been studied in detail. Analytical solutions are obtained for a rectangular and for a Gaussian bunch shape. It is shown that the rate of the bunch energy loss due to the radiative interaction is equal to the power of the coherent radiation in the far zone. Numerical estimations presented in the paper show that the effects of induced energy spread due to the radiative interaction can be important for free electron lasers operating in the infrared wavelength range

  19. Investigation of ionization losses of shower electrons in electron-photon shower developed in liquid xenon by gamma quanta in the energy range 1600-3400 MeV

    International Nuclear Information System (INIS)

    Okhrymenko, L.S.; Slowinski, B.; Strugalski, Z.; Sredniawa, B.

    1975-01-01

    Results of the investigation of differential distributions of ionization losses and the corresponding fluctuations for shower electrons in the longitudinal development of electron-photon showers produced by gamma-quanta of energies Esub(γ)=1600-3400 MeV in liquid xenon are given. A simple and convenient from the methodical point of view two-parametric function, approximating the observed distribution has been obtained. The independence of the fluctuations of ionization losses of shower electrons on the energy of gamma-quanta in the investigated interval of Esub(γ) values has been found

  20. Simulation of energy deposit distribution in water for 10 and 25 MeV electron beams

    International Nuclear Information System (INIS)

    Borrell Carbonell, Maria de los Angeles.

    1977-01-01

    The Monte Carlo method was applied to transport simulation of electron beams from the exit window of a linear accelerator till the absorption by a water phantom. The distribution of energy deposit is calculated for ideal apparatus and experimental conditions. Calculations are made for a distance window-water surface of one meter, for 10 and 25 MeV monoenergetic incident electrons, and for different fields (15x15 cm 2 to 4x4 cm 2 ). Comparisons with experimental measurements obtained in comparable conditions with a Sagittaire accelerator (C.G.R.-MeV), show a good agreement concerning radial distribution and depth distribution around isodose 100%. However a certain disagreement appears in the end of depth penetration [fr

  1. Moving strip technique of electron beam therapy

    Energy Technology Data Exchange (ETDEWEB)

    Matsushima, Kishio; Wakasa, Hiroyuki; Oguri, Nobuhiro; Kitayama, Takuichi; Nakagiri, Yoshitada; Mikami, Yasutaka; Hashimoto, Keiji; Hiraki, Yoshio; Aono, Kaname

    1984-12-01

    The fieldsize in electron beam therapy is determined by the cone size. In case of skin metastasis of a malignant tumor and so on, which need a large field size and whose area is much larger than the size of the cone, a large field size is usually produced by dividing the portals. However, the dose distribution at the border of the field becomes unequal, and hot and cold dose areas are produced according to the distance between portals. We tried the strip field technique in a large field along the long axis of the body in order to flatten the dose of the border employing the moving strip used for whole abdominal irradiation in ovarian cancer. We set the film in Mix-DP and used the strip field technique with 2.5cm steps. We discussed the relationship between the interval (distance between portals) and the flattening of the dose within the field. Skin movement due to breathing and influences on the flattening of the dose were considered. The proper flatness was obtained at depths of 0,1,2, and 3cm by setting the interval at 0.5cm. When skin movement was produced by breathing in +-1.5mm, the proper flaness was obtained also at a 0.5-cm interval. It seems that smoothing is increased by breathing. An ''electron beam moving strip'' with a 2.5-cm step and 0.5-cm interval was clinically effective in the treatment of patients with skin metastasis of colon cancer. (author).

  2. 8 MeV electron beam induced modifications in the thermal, structural and electrical properties of nanophase CeO2 for potential electronics applications

    Science.gov (United States)

    Babitha, K. K.; Sreedevi, A.; Priyanka, K. P.; Ganesh, S.; Varghese, Thomas

    2018-06-01

    The effect of 8 MeV electron beam irradiation on the thermal, structural and electrical properties of CeO2 nanoparticles synthesized by chemical precipitation route was investigated. The dose dependent effect of electron irradiation was studied using various characterization techniques such as, thermogravimetric and differential thermal analyses, X-ray diffraction, Fourier transformed infrared spectroscopy and impedance spectroscopy. Systematic investigation based on the results of structural studies confirm that electron beam irradiation induces defects and particle size variation on CeO2 nanoparticles, which in turn results improvements in AC conductivity, dielectric constant and loss tangent. Structural modifications and high value of dielectric constant for CeO2 nanoparticles due to electron beam irradiation make it as a promising material for the fabrication of gate dielectric in metal oxide semiconductor devices.

  3. Variation of carrier concentration and interface trap density in 8MeV electron irradiated c-Si solar cells

    Energy Technology Data Exchange (ETDEWEB)

    Bhat, Sathyanarayana, E-mail: asharao76@gmail.com; Rao, Asha, E-mail: asharao76@gmail.com [Department of Physics, Mangalore Institute of Technology and Engineering, Moodabidri, Mangalore-574225 (India); Krishnan, Sheeja [Department of Physics, Sri Devi Institute of Technology, Kenjar, Mangalore-574142 (India); Sanjeev, Ganesh [Microtron Centre, Department of Physics, Mangalore University, Mangalagangothri-574199 (India); Suresh, E. P. [Solar Panel Division, ISRO Satellite Centre, Bangalore-560017 (India)

    2014-04-24

    The capacitance and conductance measurements were carried out for c-Si solar cells, irradiated with 8 MeV electrons with doses ranging from 5kGy – 100kGy in order to investigate the anomalous degradation of the cells in the radiation harsh environments. Capacitance – Voltage measurements indicate that there is a slight reduction in the carrier concentration upon electron irradiation due to the creation of radiation induced defects. The conductance measurement results reveal that the interface state densities and the trap time constant increases with electron dose due to displacement damages in c-Si solar cells.

  4. Optimization calculations for slow neutron production with the 136 MeV Harwell electron linac

    International Nuclear Information System (INIS)

    Needham, J.; Sinclair, R.N.

    1978-10-01

    The new 136 MeV Harwell electron linac is to be used to produce pulsed beams of slow neutrons for condensed matter research. Design details and performance of the two types of moderator which will be available have been optimised using a Monte Carlo neutronics code (TIMOC). The choice of reflector, the necessary decoupling energy to prevent pulse broadening and the influence of γ shields and moderator shape have been investigated. The predicted yield of leakage neutrons of energy 1 eV is compared to published values for comparable facilities. (author)

  5. An 8 MeV H- cyclotron to charge the electron cooling system for HESR

    International Nuclear Information System (INIS)

    Pakhomchuk, V.; Papash, A.

    2006-01-01

    A compact cyclotron to accelerate negative hydrogen ions up to 8 MeV is considered as optimal solution to the problem of charging the high-voltage terminal of the electron cooling system for High Energy Storage Ring at GSI (HESR Project, Darmstadt). Physical as well as technical parameters of the accelerator are estimated. Different types of commercially available cyclotrons are compared as a possible source of a 1 mA H - beam for the HESR. An original design based on the application of well-established technical solutions for commercial accelerators is proposed

  6. Evolution of defects in a multicomponent glass irradiated by 1 MeV electrons

    International Nuclear Information System (INIS)

    Wang Qingyan; Geng Hongbin; Sun Chengyue; Zhang Zhonghua; He Shiyu

    2010-01-01

    The optical properties and microstructural degradation of a multicomponent glass after exposure to 1 MeV electrons for fluences of 10 13 to 10 16 e - /cm 2 , as well as the recovery during annealing at room temperature (RT) for the fluence of 10 16 e - /cm 2 , are investigated. The non-bridging oxygen hole centers (NBOHCs), as well as trapped electrons (TEs), are mainly attributed to optical absorption bands and paramagnetic spectra. In comparison of the exponential curves, the in-growth kinetics for each type of defect with increasing fluence are separable, and a new linearly-combined exponential model is used to describe the structural responses during irradiation. Accordingly, RT bleaching curves of defects follow a linearly-combined exponential decay function. Consistent results from optical and paramagnetic signals suggest that this linearly-combined model provides a reasonable kinetic description of the growth and bleaching process of defects.

  7. Number distribution of emitted electrons by MeV H+ impact on carbon

    Science.gov (United States)

    Ogawa, H.; Koyanagi, Y.; Hongo, N.; Ishii, K.; Kaneko, T.

    2017-09-01

    The statistical distributions of the number of the forward- and backward-emitted secondary electrons (SE's) from a thin carbon foil have been measured in coincidence with foil-transmitted H+ ions of 0.5-3.0 MeV in every 0.5 MeV step. The measured SE energy spectra were fitted by assuming a Pólya distribution for the simultaneous n-SE emission probabilities. For our previous data with a couple of the carbon foils with different thicknesses, a similar analysis has been carried out. As a result, it was found that the measured spectra could be reproduced as well as by an analysis without placing any restriction on the emission probabilities both for the forward and backward SE emission. The obtained b-parameter of the Pólya distribution, which is a measure of the deviation from a Poisson distribution due to the cascade multiplication by high energy internal SE's, increases monotonically with the incident energy of proton beams. On the other hand, a clear foil-thickness dependence is not observed for the b-parameter. A theoretical model which could reproduced the magnitude of the b-parameter for the SE energy spectra obtained with thick Au, Cu and Al targets is found to overestimates our values for thin carbon foils significantly. Another model calculation is found to reproduce our b-values very well.

  8. NSLS 3: Conceptual design report: 750 MeV e+ or e- injector

    International Nuclear Information System (INIS)

    1986-05-01

    The 750 MeV positron or electron injector is comprised of an electron linear accelerator which accelerates an intense beam of electrons to an energy of about 250 MeV, a positron converter, a second linear accelerator that boosts the final positron energy to 750 MeV, and a damping ring in which radiation damping is used to reduce the emittance of the positron beam for injection into the storage rings. The reasons for the need of a new injector are enumerated. The conceptual design of the system and its component systems are described, as well as project cost, schedule, and manpower requirements

  9. Radiation Shielding Analyses of A 10 MeV, 15kW LINAC for Electron Beam and X-ray at KACST

    Energy Technology Data Exchange (ETDEWEB)

    Kang, W. G.; Pyo, S. H.; Han, B. S.; Kang, C. M. [EB Tech Co., Daejeon (Korea, Republic of); Alkhuraiji, T. S. [King AbdulAziz City for Science and Technology, Riyadh (Saudi Arabia)

    2016-10-15

    The King AbdulAziz City for Science and Technology (KACST) in the Kingdom of Saudi Arabia has a plan to build a 10 MeV, 15kW linear accelerator (LINAC) for electron beam and X-ray, which is to be supplied by EB Tech in Republic of Korea. The design and construction of the accelerator building will be carried out jointly between EB Tech and KACST. Recommendations for the design and installation of radiation shielding for x-ray and gamma-ray can be found in NCRP No. 49(1976) and for accelerators with energies over 10 MeV in NCRP No. 151 (2005). Monte Carlo calculations were conducted using the MCNP6 code to determine photon fluxes and doses at the point detectors locations around the accelerator building. The problem was run as an electron, photon and neutron transport problem to account for all reactions including the (γ,n) reaction. The detectors where the DXTRAN spheres were used are indicated in the table. The computation was continued until electrons reached a total of 1x10{sup +8} histories.

  10. Two-section linear direct-current accelerator of 1.2 MeV electrons. Mean beam current of 50 mA

    International Nuclear Information System (INIS)

    Alimov, A.S.; Ermakov, D.I.; Ishkhanov, B.S.; Shvedunov, V.I.; Sakharov, V.P.; Trower, W.P.

    2002-01-01

    The theoretical and experimental results, obtained by simulation, creation and start-up of the two-section linear electron accelerator, are presented. The following beam parameters: beam current of 49 mA, mean energy of 1.2 MeV, of 59 kV, normalized emittance of 11 mm mrad are determined on the basis of the data on the beam dynamics simulation and the accelerating structure optimization. Special attention is paid to the choice of the version of the SHF-supply system of the two-section accelerator. The version of the SHF-supply system, based on the sections phasing, operating in the auto-oscillation model by means of the synchronizing signal from the feedback chain of the first section into the feedback chain of the second section, is considered. The electron beam parameters on the accelerator outlet (beam current - 44 mA, beam energy - 1.15 MeV, beam efficiency - 50.6 kW) proved to be close to the simulation results [ru

  11. Application of the Ethanol-Chlorobenzene Dosimeter to Electron Beam Dosimetry: Pulsed 10 MeV Electrons

    Energy Technology Data Exchange (ETDEWEB)

    Dvornik, I.; Razem, D.; Baric, M. [Institute ' ' Ruder Boskovic' ' , Zagreb, Yugoslavia (Croatia)

    1969-12-15

    With gamma irradiation, the ethanol-chlorobenzene chemical dosimetric systems have shown valuable properties. They are simple to prepare and analyse, the G(HC1) values are not sensitive to normal impurities and are constant within the dose range of interest for processing. This paper describes the experiments performed with 10 MeV pulsed electrons from the linear accelerator of the Research Establishment Riso, Denmark (7 microsecond pulses repeated 300 times per second, 10{sup 9} rad/sec in the pulse). The irradiations were calibrated calorimetrically. The G(HC1) values independent of dose up to 40 Mrad are given as a function of chlorobenzene concentration. The comparison with gamma irradiations shows only insignificant differences in the G-values. Above 10 vol. % chlorobenzene the G-values are approximately constant up to 20 Mrad or more, and are to within 2% equal to those obtained for gamma rays with free access of air. The addition of 0.04% of acetone or benzene to the systems had within the experimental error, no influence upon the G(HC1). The results show the applicability of ethanol-chlorobenzene dosimeters to the dosimetry of electron beam irradiations at dose rates as high as 10{sup 9} rad/sec and dosages up to 6 Mrad. (author)

  12. Study of interactions of a electron beam of 10 MeV energy and matter

    International Nuclear Information System (INIS)

    Askri, Boubaker

    2002-01-01

    In this work, we tried to extend the algorithm of the Monte Carlo method to the case of relativistic electrons of energy 10 MeV through the material, after appropriate to the simple case of non-relativistic electrons of energy 20 keV. It was determined the coefficients of reflection, transmission and absorption of electrons through the middle in both cases. As the energy and angular distributions of electrons transmitted. The results show a fairly good precision on the determination of the three coefficients. For the non-relativistic case, it was in 1000 simulations of 1000 lots electrons for gold and aluminum, it has reached an accuracy of about 0.5 pour cent. For the relativistic case, it was 20 lots of simulations for 500 electrons carbon and aluminum. we reached an accuracy of about 2, 5 pour cent determining the coefficients. The energy and angular distributions of electrons transmitted, are close those derived from the program GEANT, taken as a reference and as comparison tool. It hopes to increase the accuracy by increasing the number of lots and the size of each batch of electrons. However, the process took six days to simulate ten miles electrons under normal conditions on the HP9000 machine calculation takes a greatest time of execution for a statistical sample of smaller great. Several criteria are necessary to optimize the study. About improving the theoretical model and the algorithm, and implementation the procedure on a machine more powerful computing. (Author)

  13. Irradiation effects of 6 MeV electron on electrical properties of Al/Al2O3/n-Si MOS capacitors

    International Nuclear Information System (INIS)

    Laha, P.; Banerjee, I.; Bajaj, A.; Chakraborty, P.; Barhai, P.K.; Dahiwale, S.S.; Das, A.K.; Bhoraskar, V.N.; Kim, D.; Mahapatra, S.K.

    2012-01-01

    The influence of 6 MeV electron irradiation on the electrical properties of Al/Al 2 O 3 /n-Si metal–oxide–semiconductor (MOS) capacitors has been investigated. Using rf magnetron sputtering deposition technique, Al/Al 2 O 3 /n-Si MOS capacitors were fabricated and such twelve capacitors were divided into four groups. The first group of MOS capacitors was not irradiated with 6 MeV electrons and treated as virgin. The second group, third group and fourth group of MOS capacitors were irradiated with 6 MeV electrons at 10 kGy, 20 kGy, and 30 kGy doses, respectively, keeping the dose rate ∼1 kGy/min. The variations in crystallinity of the virgin and irradiated MOS capacitors have been compared from GIXRD (Grazing Incidence X-ray Diffraction) spectra. Thickness and in-depth elemental distributions of individual layers were performed using Secondary Ion Mass Spectrometry (SIMS). The device parameters like flat band voltage (V FB ) and interface trap density (D it ) of virgin and irradiated MOS capacitors have been calculated from C vs V and G/ω vs V curve, respectively. The electrical properties of the capacitors were investigated from the tan δ vs V graph. The device parameters were estimated using C–V and G/ω–V measurements. Poole–Frenkel coefficient (β PF ) of the MOS capacitors was determined from leakage current (I)–voltage (V) measurement. The leakage current mechanism was proposed from the β PF value. - Highlights: ► The electron irradiation effects make variation in the device parameters. ► The device parameters changes due to percentage of defects and charge trapping. ► Leakage current of Al/Al 2 O 3 /n-Si changes due to interface dangling bonds. ► The leakage current mechanism of MOS structures is due to Poole-Frenkel effect.

  14. Dose Mapping of Frozen Chickens Using 10 MeV Electrons

    International Nuclear Information System (INIS)

    Eichenberger, C.; Haider, S.A.; Maxim, J.; Miller, R.B.

    2005-09-01

    Irradiation of locally produced and imported food products was approved in the Kingdom of Saudi Arabia (KSA) in 2002. SureBeam Middle East (SME) has constructed the first food irradiation facility in Riyadh, KSA and will begin production irradiation in Q4 of 2005. In an effort to find efficient and cost effective means of irradiating frozen whole body chickens, SME has sponsored dose mapping studies using a 10 MeV dual electron beam processing system at the Electron Beam Food Research Facility at Texas A and M University (TAMU). Frozen chickens available to consumers in KSA range in size from nominal 600 grams to 1400 grams. Poultry processors typically provide retailers with equal weight birds packaged ten to a box (2 rows of 5 birds). Areal densities of the packages increase with the weight of the birds. For this study equivalent size birds were grown and processed by the Department of Poultry Science at TAMU and packaged in the same manner as in KSA. The goal of this investigation was to determine which size birds could be processed at a minimum dose of 2.5 kGy and not have the maximum dose exceed the level where negative sensory effects become noticeable. The minimum dose was chosen to reduce the population of any salmonella contamination by more than a factor of 1000. A description of the experimental set up and results of the dose mapping of frozen whole body chickens are reported herein, as are the results which indicate that electron beam processing of frozen chickens up to approximately 1000 grams can be readily accomplished and that processing of chickens up to 1400 grams may be possible Salmonella

  15. Preliminary examination of induced radio activity in pepper by 10 MeV electron irradiation

    International Nuclear Information System (INIS)

    Furuta, Masakazu; Katayama, Tadashi; Ito, Norio; Mizohata, Akira; Matsunami, Tadao; Toratani, Hirokazu; Takeda, Atsuhiko

    1989-01-01

    β-ray measurement was performed on 10 MeV electron-irradiated black pepper and white pepper in order to reconfirm the wholesomeness of irradiated food and present unambiguous data to general consumers concerning about the induced radioactivity in the irradiated foods. From elemental composition of the samples and investigation of photonuclear reactions, several β-emmitters were listed up. But no radioactivity other than from natural sources was detected in the irradiated sample by β-ray counting with 2 π gass flow counter, suggesting that the induced β-emmitters in the irradiated sample was below the detection limit of its induced radioactivity. (author)

  16. Sudden Intensity Increases and Radial Gradient Changes of Cosmic Ray Mev Electrons and Protons Observed at Voyager 1 Beyond 111 AU in the Heliosheath

    Science.gov (United States)

    Webber, W. R.; Mcdonald, F. B.; Cummings, A. C.; Stone, E. C.; Heikkila, B.; Lal, N.

    2012-01-01

    Voyager 1 has entered regions of different propagation conditions for energetic cosmic rays in the outer heliosheathat a distance of about 111 AU from the Sun. The low energy 614 MeV galactic electron intensity increased by 20over a time period 10 days and the electron radial intensity gradient abruptly decreased from 19AU to 8AU at2009.7 at a radial distance of 111.2 AU. At about 2011.2 at a distance of 116.6 AU a second abrupt intensity increase of25 was observed for electrons. After the second sudden electron increase the radial intensity gradient increased to18AU. This large positive gradient and the 13 day periodic variations of 200 MeV particles observed near theend of 2011 indicate that V1 is still within the overall heliospheric modulating region. The implications of these resultsregarding the proximity of the heliopause are discussed.

  17. Multiple ionization of noble gases by 2.0 MeV proton impact: comparison with equi-velocity electron impact ionization

    International Nuclear Information System (INIS)

    Melo, W.S.; Santos, A.C.F.; Sant'Anna, M.M.; Sigaud, G.M.; Montenegro, E.C.

    2002-01-01

    Absolute single- and multiple-ionization cross sections of rare gases (He, Ne, Ar, Kr and Xe) have been measured for collisions with 2.0 MeV p + . A comparison is made with equi-velocity electron impact ionization cross sections as well as with the available proton impact data. For the light rare gases the single-ionization cross sections are essentially the same for both proton and electron impacts, but increasing differences appear for the heavier targets. (author). Letter-to-the-editor

  18. Confirm calculation of 12 MeV non-destructive testing electron linear accelerator target

    International Nuclear Information System (INIS)

    Ma Shudong; Zhang Rutong; Guo Yanbin; Zhou Yuan; Li Xuexian; Chen Yan

    2012-01-01

    The confirm calculation of 12 MeV non-destructive testing (NDT) electron linear accelerator (LINAC) target was studied. Firstly, the most optimal target thickness and related photon dose yield, distributions of dose rate, and related photon conversion efficiencies were got by calculation with specific analysis of the physical mechanism of the interactions between the beam and target; Secondly, the photon dose rate distribution, converter efficiencies, and thickness of various kinds of targets, such as W, Au, Ta, etc. were verified by MCNP simulation and the most optimal target was got using the MCNP code; Lastly, the calculation results of theory and MCNP were compared to confirm the validity of target calculation. (authors)

  19. 14 MeV proton activation analysis

    International Nuclear Information System (INIS)

    Constantinescu, B.; Ivanov, E.; Plostinaru, D.; Popa-Nemoiu, A.; Pascovichi, G.

    1985-01-01

    A fast nuclear nondestructive method for protein analysis using the 14 MeV proton activation has been developed. The total nitrogen content was measured through the reaction: 14 N (p,n) 14 O, (Tsub(1/2)=71 s). The 14 O activity was detected by means of its characteristic 2.312 MeV gamma-ray line with a NaI(Tl) detector. For a fast determination of a large number of samples a mechanized sistem reacting a rate of one sample per minute has been developed. The laboratory electronics comprises a multichannel analyser, a PDP computer and an electronic module comtroller. Comparison of the results obtained by the method described and the classical Kjeldal technique for samples of various cereal grains (soya bean seads, wheat, barley and corn) showed good correlation. A problem of the analysis of the whole protein region on corn and soya-bean seads, where this region is thicker (0,2 - 2 mm), is mentioned. In this case flour was proposed to be used to obtain a protein homogeneous sample and the irradiaton dose for a sample was about 33,000 Gy, mainly (99%) from protons (27 s x 100 nA x 14 MeV)

  20. 1-MeV electron beam propagation experiments in neutral gas

    International Nuclear Information System (INIS)

    Greenspan, M.A.; Rose, E.A.

    1984-01-01

    Experiments were performed studying the propagation of a 1-MeV, 10-ns electron beam at currents of 2-8 kA. Propagation was studied in a 7.6-cm-diam glass guide tube, the same tube with a conducting screen inside, and in a 3.4-m-diam chamber. In the guide tube with the screen, ion-focused propagation is observed at low pressures (≤ 40 Pa) with net current equal to beam current. At higher pressures (55-130 Pa), a notch in beam current is observed for pressure time products of ≅ 100 Pa-ns. Between 270 Pa and 1070 Pa, good propagation is again observed with net currents of 50-70% of the beam current. The net current fraction of beam current increases with increasing pressure and with decreasing beam current. At pressure above 1070 Pa, hose instability occurs, and net current nearly equal to beam current is observed. The hose frequency is in reasonable accord with theory. Nose erosion is minimized at pressures for 1000-2000 Pa depending on beam current, and increases at lower and higher pressures

  1. Scattering of 14. 0 MeV electrons. Fundamental study of the scattering foil. [Angular distribution, 14. 0 MeV, gaussian distribution

    Energy Technology Data Exchange (ETDEWEB)

    Takei, C [Kyushu Univ., Fukuoka (Japan). School of Health Sciences; Yoshimoto, S

    1977-07-01

    The angular distribution of 14.0 MeV electrons scattered by thin Al and Pb foils has been measured, since the beam flatness is important on the high energy electron therapy. These distributions measured were almost completely Gaussian. The root mean square scattering angles were obtained and were compared with the theories of Williams and Rossi. In our experiments the root mean square scattering angles obtained have the experimental errors of about 4% and 1% for 5/sup 0/ and 10/sup 0/, respectively. For Al foils of 0.5 mm to 3.0 mm the experimental values of the root mean square scattering angles are 5.49/sup 0/ and 12.43/sup 0/ and are 30% to 10% higher than those predicted by Williams. Although, these values are 4% to 9% lower than those calculated from the theory of Rossi. The root mean square scattering angles obtained with Pb foils of 0.1 mm to 0.3 mm are 9.62/sup 0/ to 18.05/sup 0/ and are 14% to 18% higher than Williams, and are 14% to 7% lower than those theoretically calculated by Rossi.

  2. Results from preliminary experiments of the 1 MeV 0.1 A D- project at CEA-Cadarache

    International Nuclear Information System (INIS)

    Simonin, A.; Fumelli, M.; Jequier, F.; Pamela, J.; Bucalossi, J.; Bottereau, J.M.; Brugnetti, R.

    1994-01-01

    A 1 MeV 0.1 A D - -beam acceleration experiment under preparation is described. It will study a simplified concept of negative ion beam electrostatic accelerator called SINGAP. Some critical HV components, like a large MV bushing or protection systems against the HV vacuum breakdowns will also be tested. The experiments reported here have been conducted during the preparatory phase of this MeV project. A negative ion source was developed and produced 1 A D - beams and j(D - )=12 mA/cm 2 beams. A new type of extraction grid was designed which traps almost 100% of the stray electrons extracted from the source plasma. A new emittance diagnostic has been successfully tested with 60-100 keV D - beams. A 1 MV 120 mA Haefely power supply has been moved from KfK, adapted and operated on a resistive load at the nominal operating characteristics. (author) 5 refs.; 6 figs

  3. Preliminary microstructural characterization by transmission electron microscopy of 14 MeV neutron irradiated type 316 stainless steel

    International Nuclear Information System (INIS)

    Echer, C.J.

    1977-01-01

    Substantial changes in the mechanical properties of 316 stainless steel were observed after neutron irradiation (phi/sub t/ = 2.3 x 10 21 n/m 2 and E = 14 MeV) at 25 0 C. Comparison of microstructures of the unirradiated and neutron irradiated materials were evaluated using transmission electron microscopy. Evidence of small defect clusters in the irradiated material was found. These findings are consistent with other investigators also evaluating low dose irradiations

  4. Calculation of energy and angular distributions of the bremsstrahlung of 10 MeV electrons bombarding a thick tungsten target

    International Nuclear Information System (INIS)

    Tsovbun, V.I.

    1977-01-01

    Computer calculations have been performed to extend the data available on energy and angular distribution of the 10 MeV electron bremsrahlung into a higher angle region. The ETRAN-16D program developed by R.G.Berger for calculation of electron-photon cascades passing through matter using computers IBM-360 and UNIVAC-1108 was modified to operate with the CDC-6500 computer. A brief summary of the program is provided. An angular distribution of the bremsstrahlung dose absorbed in the air has been also calculated. The results extended into the 90-180 deg region can be used to calculate the biological shield of electron accelerators

  5. Optimum design for 12 MeV linear induction accelerator diode

    International Nuclear Information System (INIS)

    Yu Haijun; Shi Jinshui; Li Qin; He Guorong; Ma Bing; Wang Jingsheng; Wang Liping

    2001-01-01

    A series of optimization designs of electron diode in 12 Mev linear induction accelerator are studied by using numerical simulation code MAGIC and experiment method in order to improve the electron beam quality. MAGIC code solves the Maxwell equations in the presence of charged particle, electron field distribution on cathode surface which influences electron emission is given, the optimum diode is obtained by comparing the results of experiment in 12 MeV linear induction accelerator. The author also gives SEM analysis and experiment comparison of velvet emission. Finally, emitted current I e = 8.52 kA, beam current I 8 ≥ 3.0 kA, targeted current I 0 ≥ 2.30 kA with optimum diode are obtained

  6. Slow positron beam production by a 14 MeV C.W. electron accelerator

    Science.gov (United States)

    Begemann, M.; Gräff, G.; Herminghaus, H.; Kalinowsky, H.; Ley, R.

    1982-10-01

    A 14 MeV c.w. electron accelerator is used for pair production in a tungsten target of 0.7 radiation lengths thickness. A small fraction of the positrons is thermalized and diffuses out of the surface ofsurface of a well annealed tungsten foil coated with MgO which is positioned immediately behind the target. The slow positrons are extracted from the target region and magnetically guided over a distance of 10 m onto a channelplate multiplier at the end of an S-shaped solenoid. The positrons are identified by their annihilation radiation using two NaI-detectors. The intensity of the slow positrons is proportional to the accelerator electron beam current. The maximum intensity of 2.2 × 10 5 slow positrons per second reaching thedetector at an accelerator current of 15 μA was limited by the power deposited in the uncooled target. The energy of the positrons is concentrated in a small region at about 1 eV and clearly demonstrates the emission of thermal positrons.

  7. Slow positron beam production by a 14 MeV c.w. electron accelerator

    International Nuclear Information System (INIS)

    Begemann, M.; Graeff, G.; Herminghaus, H.; Kalinowsky, H.; Ley, R.

    1982-01-01

    A 14 MeV c.w. electron accelerator is used for pair production in a tungsten target of 0.7 radiation lengths thickness. A small fraction of the positrons is thermalized and diffuses out of the surface of a well annealed tungsten foil coated with MgO which is positioned immediately behind the target. The slow positrons are extracted from the target region and magnetically guided over a distance of 10 m onto a channelplate multiplier at the end of an S-shaped solenoid. The positrons are identified by their annihilation radiation using two Nal-detectors. The intensity of the slow positrons is proportional to the accelerator electron beam current. The maximum intensity of 2.2 x 10 5 slow positrons per second reaching the detector at an accelerator current of 15 μA was limited by the power deposited in the uncooled target. The energy of the positrons is concentrated in a small region at about 1 eV and clearly demonstrates the emission of thermal positrons. (orig.)

  8. Depth distribution of damage in copper irradiated with MeV, Ni and He ions

    International Nuclear Information System (INIS)

    Narayan, J.; Noggle, T.S.; Oen, O.S.

    1975-01-01

    Transmission electron microscopy was used to study radiation damage as a function of depth caused by 58 and 4-MeV 58 Ni and 1-MeV He ions in copper single crystals at ambient temperature. The experimental damage density vs penetration depth distributions were compared with calculations based on the atomic collision theory of Lindhard et al. (LSS). For 58-MeV Ni ions, the calculated damage profile using the theoretical LSS value of the electronic stopping parameter (k = 0.167) agrees well with experiment. However, for 4-MeV Ni ions it is necessary to use k = 0.12 to get agreement with the experimental data. In the case of 1-MeV He, the depth location of the calculated damage peak is in good agreement with experiment when the electronic stopping determined by Chu and Powers is used whereas it is about 15 percent too close to the surface using the tables of Northcliffe and Schilling. (auth)

  9. Study of the yield of the Fricke dosimetry for electron energies from 2 to 90 MeV

    International Nuclear Information System (INIS)

    Berkvens, I.P.

    1988-01-01

    The chemical yield for the ferrous sulphate dosimeters was determined for 60 Co-γ radiation and for electron beams of mean energies in the points of measurements, between 2.7 and about 9 MeV. As references, absolute determinations of absorbed dose based on calorimetric measurements, were used. The irradiation geometry for the ferrous sulphate dosimeter differ always due to technical reasons somewhat from that for the absorber of the calorimeter. The investigators took this difference into account. Perturbation correction factors that correct for the difference in electron scattering in the air gaps around the absorber of the calorimeter and in the graphite, were computed with the Monte Carlo method. Also the ''reference volume method'' recently introduced by the ICRU (report No.35), was applied to correct for the introduction of a ferrous sulphate dosimeter in a graphite phantom. This correction is necessary as the electrons are stopped and scattered in a different way in graphite and water. The results indicated that there is no energy dependence of the chemical yield (G-value) of the dosimeter in the energy range 2.7 to about 9 MeV. A mean G-value of 1,584 (± 0.006) μ mol/J was obtained. For 60 Co-γ a G-value of 1.601 μ mol/J was determined. However, this difference might not be real but due to the present uncertainty in the stopping-power ratios graphite to water. These ratios are thus made use of to determine the G-value from measurements of the absorbed dose to graphite. Previous investigations, by the group from Gent, indicated a small increase of the G-value with the electron energy. These more accurate determinations thus instead indicate a constant G-value. Refs, figs, tabs

  10. Design and performance of a 3.3-MeV linear induction accelerator (LIA)

    International Nuclear Information System (INIS)

    Cheng Nianan; Zhang Shouyun; Tao Zucong

    1992-01-01

    A 3.3-MeV linear induction accelerator (LIA) has been designed and constructed at the China Academy of Engineering Physics. The parameters of 3.4 MeV, 2 kA, 80 ns and 1 x 10 4 A/(rad.cm) 2 have been achieved. It has been used for SG-1 FEL experiments. The accelerator is mounted on a movable frame so that , after moving 3 m transversely, it can be assembled with more modules into a 10-MeV LIA. The authors summarize the physics and engineering aspects of the LIA facility and describe the measuring means of characters for the beam

  11. Microwave matching and tuning on the 20-MeV medical electron linac with feedback of rf power

    International Nuclear Information System (INIS)

    Yuan-ling, Wang

    1983-01-01

    This article describes the 20 Mev medical electron linac at Jiangsu Tumour Hospital. In the linac, feedback of rf power is used. In the linac with feedback (or with the resonator) the reflection affects the energy gain of the electron and the performance of the accelerator. By means of the theory of the traveling wave resonator, the field multiplication factor and the reflection coefficients inside and outside the feedback ring are calculated. The bands of the linacs without and with feedback are measured. In order to achieve a desirable band in front of the load (i.e. outside the feedback ring) a matching iris is added. After the linac with feedback has been matched, the band is given

  12. On radiation of electrons moving in braking electric fields with distributed potential

    International Nuclear Information System (INIS)

    Fedulov, V.I.; Suvorov, V.I.; Umirov, U.R.

    2002-01-01

    The characteristics of radiation of electron moving in flat structures with braking electric field created by an accelerating electrode and another electrode with distributed potential are investigated. The analytical expressions for definition of conditions for complete loss of energy by electron in structure with distributed potential and for arising the electron vibrations are received. Also expressions connecting the electron energy with the point of entry and its fluctuation frequency are received. The mathematical model of irradiation process is offered depending on energy and point of entry of the electron. The connection between a radiation wave length and position of point of entry of electrons in the braking electric field are found. A possibility of emerging the optical radiation in solid environments at passage of charge particles through substance is shown. (author)

  13. Operation of the APEX photoinjector accelerator at 40 MeV

    International Nuclear Information System (INIS)

    Feldman, D.W.; Bender, S.C.; Byrd, D.A.; Carlsten, B.E.; Early, J.W.; Feldman, R.B.; Goldstein, J.C.; Martineau, R.L.; O'Shea, P.G.; Pitcher, E.J.; Schmitt, M.J.; Stein, W.E.; Wilke, M.D.; Zaugg, T.J.

    1992-01-01

    We have successfully operated the photoinjector and rf linear accelerator for the Los Alamos APEX free electron laser (FEL) at design energy, average macropulse current, and emittance. The accelerator, which operates at 1.3 GHz, consists of a 6 MeV photoinjector and three standing-wave structures with a total beam energy of 40 MeV. This paper presents performance characteristics of the APEX system. The results show that this technology is capable of providing reliable, high-peak current, ultra-high brightness electron beams

  14. Simulation of enhanced characteristic x rays from a 40-MeV electron beam laser accelerated in plasma

    Directory of Open Access Journals (Sweden)

    L. Nikzad

    2012-02-01

    Full Text Available Simulation of x-ray generation from bombardment of various solid targets by quasimonoenergetic electrons is considered. The electron bunches are accelerated in a plasma produced by interaction of 500 mJ, 30 femtosecond laser pulses with a helium gas jet. These relativistic electrons propagate in the ion channel generated in the wake of the laser pulse. A beam of MeV electrons can interact with targets to generate x-ray radiation with keV energy. The MCNP-4C code based on Monte Carlo simulation is employed to compare the production of bremsstrahlung and characteristic x rays between 10 and 100 keV by using two quasi-Maxwellian and quasimonoenergetic energy distributions of electrons. For a specific electron spectrum and a definite sample, the maximum x-ray flux varies with the target thickness. Besides, by increasing the target atomic number, the maximum x-ray flux is increased and shifted towards a higher energy level. It is shown that by using the quasimonoenergetic electron profile, a more intense x ray can be produced relative to the quasi-Maxwellian profile (with the same total energy, representing up to 77% flux enhancement at K_{α} energy.

  15. 3 MeV DC accelerator, EBC Kharghar

    International Nuclear Information System (INIS)

    Bakhtsingh, R.I.; Acharya, S.

    2017-01-01

    The Accelerator and Pulse Power Division (APPD) has designed and developed a 3 MeV, 10 mA DC electron beam accelerator at Electron Beam Centre, Kharghar, Navi Mumbai. This machine has been utilized for reduction of SO_x and NO_x in simulated flue gases and treatment of waste water to reduce COD and BOD

  16. Lactose and sucrose aqueous solutions for high-dose dosimetry with 10-MeV electron beam irradiation

    International Nuclear Information System (INIS)

    Amraei, R.; Kheirkhah, M.; Raisali, G.

    2012-01-01

    In the present study, dosimetric characterisation of aqueous solutions of lactose and sucrose was analysed by UV spectrometry following irradiation using 10-MeV electron beam at doses between 0.5 and 10.5 kGy. As a dosimetric index, absorbance is selected at 256 and 264 nm for lactose and sucrose aqueous solutions, respectively. The intensity of absorbance for irradiated solutions depends on the pre-irradiation concentration of lactose and sucrose. The post-irradiation stability of both solutions was investigated at room temperature for a measurement period of 22 d. (authors)

  17. Radiation-induced damage and recovery effects in GG17 glass irradiated by 1 MeV electrons

    International Nuclear Information System (INIS)

    Wang Qingyan; Zhang Zhonghua; Geng Hongbin; Sun Chengyue; Yang Dezhuang; He Shiyu; Hu Zhaochu

    2012-01-01

    The optical properties and microstructural damage of GG17 glasses, as well as their recovery during annealing at room temperature, are investigated after exposure to 1 MeV electrons with various fluences. Experimental results show that the electrons lead to severe optical degradation in the GG17 glass, and induce the formation of paramagnetic defects which can be mainly attributed to the boron–oxygen hole centers. With increasing annealing time at room temperature their decay serves as long-lived defects following first order kinetics. Except for the strong absorption bands located at 334–352 nm and 480 nm that corresponds to the boron–oxygen hole centers, weaker absorption bands appear at 780 nm or 794.6 nm after irradiation, inducing a decrease in transmittance by approximately 17% for a fluence of 1 × 10 16 cm −2 . It is shown that electron irradiation could cause a harmful effect on rubidium lamps when GG17 glass is used as the lamp envelope material.

  18. 2 MeV/20 kW industrial electron beam accelerator vis-s-vis its vacuum system

    International Nuclear Information System (INIS)

    Khader, S.A.; Assadullah, M.; Sarma, K.S.S.; Bandi, L.N.

    2003-01-01

    Full text: Electron beam accelerators in the energy range 200 keV to 10 MeV have been extensively used for many radiation processing applications that include polymerization, polymer modifications, radiation sterilization, food irradiation and gem coloration. The accelerator technology is a multidisciplinary one wherein production of stable vacuum in various accelerator systems is of utmost importance to achieve required output beam parameters like beam energy and current for processing industrial products at large through puts on continuous basis. A 2 MeV, 20 kW industrial electron beam accelerator has been in operation since 2001 at BARC-BRIT complex, Navi Mumbai for commercial and R and D applications like crosslinking of wire and cables, heat shrinkable tubes, PE O rings, PTEE degradation and color enhancement in diamonds. The machine is a ILU-6 type pulse RF accelerator consisting of a single resonator copper cavity of 1.2 m diameter and 1.2 m height (volume:∼ 1.5 m3) placed inside a stainless steel container (called cavity container) and a s.s. beam extraction window wherein vacuum needs to be maintained at a minimum 10-6 torr. Four sputter ion pumps are directly fixed on the cavity container to obtain maximum pumping efficiency. The fore vacuum is generated using a combination rotary and a roots pump. The beam extraction widow has a 50 and 956 m thick titanium foil acting as the exit window for electrons from the vacuum into air. Both the cavity and the beam extraction window are coupled through a gate valve which acts as a vacuum separator isolating the systems from each other during foil puncture, scanning system failure or any other related problems. This paper reports details of the vacuum system, measurements, vacuum leaks and detection and the operational experience related to maintenance and troubleshooting exercises that have been carried in the accelerator

  19. Prognoz 4 observations of electrons accelerated up to energies <=2 MeV and of the cold plasma between the magnetopause and the bow shock

    International Nuclear Information System (INIS)

    Mineev, Yu.V.; Spir'kova, E.S.

    1980-05-01

    The experimental data from Prognoz 4 satellite obtained on a layer of electrons with energies <=2 MeV in the magnetosheath adjacent to magnetopause at different latitudes are given. At moderate latitudes the data are in favour of the leakage of electrons from the outer radiation belt as a source of the layer considered. At high latitudes these electrons apparently arrive along magnetosheath magnetic field lines trapping the magnetopause. (author)

  20. Ambient-temperature diffusion and gettering of Pt atoms in GaN with surface defect region under 60Co gamma or MeV electron irradiation

    Science.gov (United States)

    Hou, Ruixiang; Li, Lei; Fang, Xin; Xie, Ziang; Li, Shuti; Song, Weidong; Huang, Rong; Zhang, Jicai; Huang, Zengli; Li, Qiangjie; Xu, Wanjing; Fu, Engang; Qin, G. G.

    2018-01-01

    Generally, the diffusion and gettering of impurities in GaN needs high temperature. Calculated with the ambient-temperature extrapolation value of the high temperature diffusivity of Pt atoms in GaN reported in literature, the time required for Pt atoms diffusing 1 nm in GaN at ambient temperature is about 19 years. Therefore, the ambient-temperature diffusion and gettering of Pt atoms in GaN can hardly be observed. In this work, the ambient-temperature diffusion and gettering of Pt atoms in GaN is reported for the first time. It is demonstrated by use of secondary ion mass spectroscopy that in the condition of introducing a defect region on the GaN film surface by plasma, and subsequently, irradiated by 60Co gamma-ray or 3 MeV electrons, the ambient-temperature diffusion and gettering of Pt atoms in GaN can be detected. It is more obvious with larger irradiation dose and higher plasma power. With a similar surface defect region, the ambient-temperature diffusion and gettering of Pt atoms in GaN stimulated by 3 MeV electron irradiation is more marked than that stimulated by gamma irradiation. The physical mechanism of ambient-temperature diffusion and gettering of Pt atoms in a GaN film with a surface defect region stimulated by gamma or MeV electron irradiation is discussed.

  1. A Monte Carlo simulation code for calculating damage and particle transport in solids: The case for electron-bombarded solids for electron energies up to 900 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Yan, Qiang [College of Nuclear Science and Technology, Harbin Engineering University, Harbin 150001 (China); Shao, Lin, E-mail: lshao@tamu.edu [Department of Nuclear Engineering, Texas A& M University, College Station, TX 77843 (United States)

    2017-03-15

    Current popular Monte Carlo simulation codes for simulating electron bombardment in solids focus primarily on electron trajectories, instead of electron-induced displacements. Here we report a Monte Carol simulation code, DEEPER (damage creation and particle transport in matter), developed for calculating 3-D distributions of displacements produced by electrons of incident energies up to 900 MeV. Electron elastic scattering is calculated by using full-Mott cross sections for high accuracy, and primary-knock-on-atoms (PKAs)-induced damage cascades are modeled using ZBL potential. We compare and show large differences in 3-D distributions of displacements and electrons in electron-irradiated Fe. The distributions of total displacements are similar to that of PKAs at low electron energies. But they are substantially different for higher energy electrons due to the shifting of PKA energy spectra towards higher energies. The study is important to evaluate electron-induced radiation damage, for the applications using high flux electron beams to intentionally introduce defects and using an electron analysis beam for microstructural characterization of nuclear materials.

  2. Generation of 300 MeV Quasi-Monochromatic Electron Beams from Laser Wakefield and Initiation of Photonuclear Reactions

    Science.gov (United States)

    Maksimchuk, A.; Beene, J. R.

    2005-10-01

    In the interaction of 30 fs, 40 TW Ti:sapphire Hercules laser at the University of Michigan, which is focused to the intensity of 10^19 W/cm^2 onto a supersonic He gas jet with electron density close to the resonant density, we observed quasi-monoenergetic electron beams with energy up to 300 MeV and angular divergence of about 10 mrad. The results on characterization of relativistic electron beam in terms of energy spread, its charge, divergence and pointing stability will be presented. 2D PIC simulations performed for the parameters close to the experimental conditions show the evolution of the laser pulse in plasma, electron injection, and the specifics of electron acceleration observed in experiments. Resulted relativistic electron beams have been used to perform gamma-neutron activation of ^12C and ^63Cu and photo-fission of ^238U. We demonstrated that approximately 10^6 reaction per shot has been produced in each case. This work was supported by the NSF through the Physics Frontier Center FOCUS. JRB, DRS, DWS, and CRV acknowledge support by the DOE under contract DE-AC05-00OR22725 with UT-Battelle, LLC.

  3. Influence of 2 MeV electrons irradiation on gallium phosphide light-emitting diodes reverse currents

    Directory of Open Access Journals (Sweden)

    V. G. Vorobiov

    2015-10-01

    Full Text Available Results of reverse electrophysical characteristics study of red and green LEDs, initial and irradiated with 2 MeV electrons were given. It was found that reverse current was predominantly caused by carriers tunneling at Urev ≤ 9 V, and by the avalanche multiplication at Urev ≥ 13 V, in the range U = 9 ÷ 13 V both mechanisms are available. Current increase at high voltage areas (Urev > 19 V is limited by the base resistance of diode. In the case of significant reverse currents (I > 1 mA irradiation of diodes leads to the shift of reverse current-voltage characteristics into the high voltages direction.

  4. Effect of 1MeV electron beam on transistors and circuits

    International Nuclear Information System (INIS)

    Lee, Tae Hoon

    1998-02-01

    It has been known that semiconductor devices operating in a radiation environment exhibited significant alterations of their electrical responses. Since an electron beam bombardment produces lattice damage in Si and charged defects in SiO 2 , several electrical parameters of transistors exhibit significant changes. Those parameters are the current gain of BJT (Bipolar Junction Transistor) and the threshold voltage of MOSFET (Metal Oxide Semiconductor Field Effect Transistor). The degradation of transistors brings about that of circuits. This paper presents the results of experiments and simulations performed to study the effects of 1MeV electron beam irradiation on selected silicon transistors and circuits. For BJTs, the current gains of npn (2N3904) and pnp (2N3906) linearly decreased as the irradiation dose increased, and from this result, the damage constants, Ks were obtained as 13.65 for 2N3904 and 22.52 for 2N3906 in MGy, indicating a more stable operation in the electron radiation environment for pnp than that for npn. The decrease of current gain was due to that of minority-carrier lifetime in the base region. For MOSFETs (CD4007s), the threshold voltages of NMOS and PMOS shifted to the lower values, which was resulted from the accumulation of charge in SiO 2 . The charges could be categorized into fixed oxide charge and interfacial trap charge. From experimental results, the amounts of the induced charges could be quantitatively estimated. These degradations of transistors brought about the decrease in the voltage gain of CE (Common Emitter) amplifier and the shifts in the inverting voltage of inverter. Additionally, PSpice simulations of these circuits were carried out by modeling of irradiated transistors. The comparison of simulation with experiment showed the relatively good agreement of simulation for the degradation of circuits after irradiation

  5. The radiation field measurement and analysis outside the shielding of A 10 MeV electron irradiation accelerator

    Science.gov (United States)

    Shang, Jing; Li, Juexin; Xu, Bing; Li, Yuxiong

    2011-10-01

    Electron accelerators are employed widely for diverse purposes in the irradiation-processing industry, from sterilizing medical products to treating gemstones. Because accelerators offer high efficiency, high power, and require little preventative maintenance, they are becoming more and more popular than using the 60Co isotope approach. However, the electron accelerator exposes potential radiation hazards. To protect workers and the public from exposure to radiation, the radiation field around the electronic accelerator must be assessed, especially that outside the shielding. Thus, we measured the radiation dose at different positions outside the shielding of a 10-MeV electron accelerator using a new data-acquisition unit named Mini-DDL (Mini-Digital Data Logging). The measurements accurately reflect the accelerator's radiation status. In this paper, we present our findings, results and compare them with our theoretical calculations. We conclude that the measurements taken outside the irradiation hall are consistent with the findings from our calculations, except in the maze outside the door of the accelerator room. We discuss the reason for this discrepancy.

  6. The radiation field measurement and analysis outside the shielding of A 10 MeV electron irradiation accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Shang Jing [National Synchrotron Radiation Lab, University of Science and Technology of China (China); Li Juexin, E-mail: juexin@ustc.edu.cn [National Synchrotron Radiation Lab, University of Science and Technology of China (China); Xu Bing; Li Yuxiong [National Synchrotron Radiation Lab, University of Science and Technology of China (China)

    2011-10-01

    Electron accelerators are employed widely for diverse purposes in the irradiation-processing industry, from sterilizing medical products to treating gemstones. Because accelerators offer high efficiency, high power, and require little preventative maintenance, they are becoming more and more popular than using the {sup 60}Co isotope approach. However, the electron accelerator exposes potential radiation hazards. To protect workers and the public from exposure to radiation, the radiation field around the electronic accelerator must be assessed, especially that outside the shielding. Thus, we measured the radiation dose at different positions outside the shielding of a 10-MeV electron accelerator using a new data-acquisition unit named Mini-DDL (Mini-Digital Data Logging). The measurements accurately reflect the accelerator's radiation status. In this paper, we present our findings, results and compare them with our theoretical calculations. We conclude that the measurements taken outside the irradiation hall are consistent with the findings from our calculations, except in the maze outside the door of the accelerator room. We discuss the reason for this discrepancy.

  7. Fibre optic control for electron gun power supplies and data acquisition of 3 MeV DC accelerator

    International Nuclear Information System (INIS)

    Chavan, R.B.; Yadav, Vivek; Dixit, K.P.; Bakhtsingh, R.I.; Rajan, Rehim; Nanu, K.; Mittal, K.C.; Chakravarthy, D.P.; Gantayet, L.M.

    2011-01-01

    A 3 MeV, 10 mA DC Industrial Electron Beam Accelerator is being commissioned at Electron Beam Centre, Navi Mumbai. The electron beam is generated by a triode electron gun and injected into the accelerating column at 5 keV. The gun and its power supplies, (5 kV anode, 3 kV grid and 15V/20A filament), are floating at 3 Million volts, and are situated in a tank which is pressurized with SF6 at 6 kg/cm 2 . These power supplies are required to be controlled remotely. The various accelerator parameters like Beam Energy, Beam Current, RF Electrode Voltage, Power Oscillator Plate Voltage / Current and Vacuum are required to be monitored during beam operation. The software was developed in VB.Net for control and data acquisition. The database is provided in SQL 2005 for storing the data. For this purpose, control system using ADAM modules and Optical fibre has been designed and developed. This paper describes the design features of the control system and experience of use of control software during initial beam trials. (author)

  8. 200 MeV RF linac for synchrotron injection

    International Nuclear Information System (INIS)

    Whitham, K.; Anamkath, H.; Lyons, S.; Manca, J.; Miller, R.; Treas, P.; Zante, T.; Miller, R.

    1992-01-01

    Construction has been completed on an electron linear accelerator for the Brookhaven National Laboratory. This accelerator will be used for the injection of a 200 MeV electron beam into a synchrotron for lithography experiments. This paper describes the conceptual design of the linac, its e-gun pulser, and its control and timing systems. 3 figs., ref

  9. Move up,Move out

    Institute of Scientific and Technical Information of China (English)

    Guo Yan

    2007-01-01

    @@ China has already become the world's largest manufacturer of cement,copper and steel.Chinese producers have moved onto the world stage and dominated the global consumer market from textiles to electronics with amazing speed and efficiency.

  10. Measures of gamma rays between 0,3 MeV and 3,0 MeV and of the 0,511 MeV annihilation line coming from Galactic Center Region

    International Nuclear Information System (INIS)

    Jardim, M.V.A.

    1982-04-01

    The detection of the flux of the electron-positron annihilation line coming from the Galactic Center direction allows one to estimate the rate of positrons production and the corresponding luminosity. The results of measurements of the annihilation line flux intensity at 0.511 MeV, obtained with a balloon borne experiment to measure gamma rays in the energy interval 0.3 to 3 MeV are presented. The detector looked at the galactic disk in the longitude interval -31 0 0 and observed a flux intensity of (6.70 +- 0.85) x 10 -3 photons cm -2 s -1 , which is in good agreement with the flux value estimated assuming that the Galactic Center is a line source emitting uniformly. Some likely sources of positrons and annhilation regions are also discussed. The results for the continuum spectrum emitted from the Galactic Center in the energy interval 0.3 to 0.67 MeV are presented and compared with measurements had already made. (Author) [pt

  11. Calculation of equivalent dose index for electrons from 5,0 to 22,0 MeV by the Monte Carlo method

    International Nuclear Information System (INIS)

    Peixoto, J.E.

    1979-01-01

    The index of equivalent dose in depth and in a sphere surface of a soft tissue equivalent material were determined by Monte Carlo method for electron irradiations from 5,0 to 22.00 MeV. The effect of different irradiation geometries which simulate the incidence of onedirectional opposite rotational and isotropic beams was studied. It is also shown that the detector of wall thickness with 0.5g/cm 2 and isotropic response com be used to measure index of equivalent dose for fast electrons. The alternative concept of average equivalent dose for radiation protection is discussed. (M.C.K.) [pt

  12. Dose measurements in the treatment of mycosis fungoides with total skin irradiation using a 4 MeV electron beam

    Energy Technology Data Exchange (ETDEWEB)

    Poli, M.E.R. [Hospital Real e Benemerita Sociedade Portuguesa de Beneficencia (Brazil); Todo, A.S.; Campos, L.L. [Instituto de Pesquisas Energeticas e Nucleares, CNEN/SP Travessa R, Sao Paulo (Brazil)

    2000-05-01

    The total skin irradiation (TSI) is one of the most efficient techniques in the treatment administered with curative intent of the mycosis fungoides. The cure may be obtained in 10% to 40% of cases. The original Stanford University technique, created in 1960, was applied in a 4.8 MeV linear accelerator, that provided 2.5 MeV electrons in the patient, by the use of 4 couple beams with the patient placed in front of the beam, 3 meters distant from the apparatus. In this work we describe a 4 MeV electrons beam treatment method. We intend to improve the uniformity of the dose in the patient, as well, to reduce the problems with the overlapping treatment fields, that occurs in conventional treatment that uses 1 meter of focus-skin distance, and the treatment time to the patient. Only one modification was done in the apparatus: the dose rate for this treatment was doubled. The patient is placed on a rotative base and he assumes successively 6 positions: stand up and perpendicular to the beam, distant 2.83 meters from the gantry, with 60 degrees of interval between the rotations. In each position, the patient receives a couple of beams (the beam angulation is 19.5 degrees above the transversal axis in the middle of the patient and 19.5 degrees below it). The dosimetric data obtained were compared to the international protocols (AAPM). The delivered doses in the patient were measured with thermoluminescent dosimeters placed on skin surface and with Kodak XV-2 films placed between different slabs of an anthropomorphic phantom. The dose distribution in the phantom shows a good uniformity, in all thickness of interest, so it is possible to use this technique in the treatment of the mycosis fungoides as well Kaposi's sarcoma. (author)

  13. Projectile-charge-state dependence of 0 degree binary-encounter electron production in 30-MeV Oq++O2 collisions

    International Nuclear Information System (INIS)

    Zouros, T.J.M.; Richard, P.; Wong, K.L.; Hidmi, H.I.; Sanders, J.M.; Liao, C.; Grabbe, S.; Bhalla, C.P.

    1994-01-01

    Double-differential cross sections (DDCS's) for the production of binary-encounter electrons (BEE's) are reported for 30-MeV O q+ +O 2 collisions. The BEE DDCS's were measured at θ=0 degree with respect to the beam direction for projectile charge states q=4--8. The measured BEE DDCS's were found to increase with decreasing charge state in agreement with other recent BEE results employing simpler H 2 and He targets. Impulse-approximation calculations of BEE production for θ=0 degree--45 degree are also presented, in which it is assumed that target electrons undergo elastic scattering in the screened Coulomb field of the projectile ion. These calculations are shown to be in agreement with our data at θ=0 degree where only 2s and 2p target electrons are considered

  14. Moving gantry method for electron beam dose profile measurement at extended source-to-surface distances.

    Science.gov (United States)

    Fekete, Gábor; Fodor, Emese; Pesznyák, Csilla

    2015-03-08

    A novel method has been put forward for very large electron beam profile measurement. With this method, absorbed dose profiles can be measured at any depth in a solid phantom for total skin electron therapy. Electron beam dose profiles were collected with two different methods. Profile measurements were performed at 0.2 and 1.2 cm depths with a parallel plate and a thimble chamber, respectively. 108cm × 108 cm and 45 cm × 45 cm projected size electron beams were scanned by vertically moving phantom and detector at 300 cm source-to-surface distance with 90° and 270° gantry angles. The profiles collected this way were used as reference. Afterwards, the phantom was fixed on the central axis and the gantry was rotated with certain angular steps. After applying correction for the different source-to-detector distances and incidence of angle, the profiles measured in the two different setups were compared. Correction formalism has been developed. The agreement between the cross profiles taken at the depth of maximum dose with the 'classical' scanning and with the new moving gantry method was better than 0.5 % in the measuring range from zero to 71.9 cm. Inverse square and attenuation corrections had to be applied. The profiles measured with the parallel plate chamber agree better than 1%, except for the penumbra region, where the maximum difference is 1.5%. With the moving gantry method, very large electron field profiles can be measured at any depth in a solid phantom with high accuracy and reproducibility and with much less time per step. No special instrumentation is needed. The method can be used for commissioning of very large electron beams for computer-assisted treatment planning, for designing beam modifiers to improve dose uniformity, and for verification of computed dose profiles.

  15. Generation and application of 15 to 30 MeV parametric X-ray by linac

    CERN Document Server

    Akimoto, T

    2002-01-01

    15 to 30 MeV parametric X-ray (PXR) was generated using Si single crystal by 45 MeV electron LINAC. To obtain good monochromatic hard X-ray field, the appropriate conditions were determined by theoretical analysis and experiments. The intensity of PXR was increased with increasing electron energy and crystal rotation angle. However, PXR energy is independent of electron energy. By increasing measurement angle, energy of PXR decreased, but its intensity increased. 15 to 30 keV PXR energy and about 10 sup - sup 5 to 10 sup - sup 6 photon/electron of intensity were observed at 15 to 22 deg detection angle under the operation conditions of 45 MeV electron energy and 4 to 8 nA of beam current. The mass attenuation coefficient of photon of Zr, Nb and Mo, in K absorption edge was measured. Application to determine lattice distortion of target sample and off-angle of crystal was investigated. Generation and detection of PXR, measurement of characteristic properties: crystal rotation angle, detection angle, electron e...

  16. Structural and electrical properties of polycrystalline CdSe thin films, before and after irradiation with 6 MeV accelerated electrons

    International Nuclear Information System (INIS)

    Ion, L.; Antohe, V.A.; Tazlaoanu, C.; Antohe, S.; Scarlat, F.

    2004-01-01

    Structural and electrical properties of polycrystalline CdSe thin films irradiated with high-energy electrons are analyzed. The samples were prepared by vacuum deposition of CdSe powder onto optical glass substrate. Their structure and the temperature dependence of the electrical resistance were determined, both before and after irradiation with 6 MeV electrons at fluencies up to 10 16 electrons/cm 2 . There were no measurable changes in the crystalline structure of the films after irradiation. Electrical properties are controlled by the defect level of donor type, possibly a selenium vacancy, with two ionizing states having ionization energies of about 0.40 eV and 0.22 eV, respectively. The major effect of the irradiation is to increase significantly the concentration of these defects. (authors)

  17. Construction of 35 MeV DSM at Nihon University

    International Nuclear Information System (INIS)

    Hayakawa, K.; Sato, K.; Tanaka, T.; Takeda, O.

    1988-01-01

    High quality electron beam is needed for the excitation of the free electron laser(FEL). Construction of the 35 MeV double-sided microtron for the FEL has been started at 1984. This accelerator will feed a electron beam which has narrow energy width and low emittance. A first one turn beam line has been completed. Beam accelerating experiments and high power microwave tests are performed. (author)

  18. 26-Day Variations of 7 MeV Electrons at high Latitudes and their Implications on the Heliospheric Magnetic Field

    Science.gov (United States)

    Sternal, Oliver; Engelbrecht, Eugene; Burger, Renier; Dunzlaff, Phillip; Ferreira, Stefan; Fichtner, Horst; Heber, Bernd; Kopp, Andreas; Potgieter, Marius; Scherer, Klaus

    The transport of energetic particles in the heliosphere is usually described by the Parker trans-port equation including the physical processes of diffusion, drift, convection and adiabatic energy changes. The Ulysses spacecraft provides unique insight into the flux of MeV electrons at high latitudes. In this contribution, we compare our model results for the Parker HMF model and the Fisk-type Schwadron-Parker HMF model to Ulysses measurements. The elec-tron flux at high latitudes has been used as a remote sensing method to investigate the imprint of a Fisk-type HMF. We show here for the first time that such an imprint exists and deduce a limitation on the Fisk HMF angle β.

  19. Modification of Modulating Anode Voltage Supply of Klystron for PEFP 20 MeV Linac

    International Nuclear Information System (INIS)

    Kim, Dae Il; Kwon, Hyeok Jung; Kim, Han Sung; Cho, Yong Sub

    2011-01-01

    The klystron (TH2089F, THALES) for PEFP 20MeV proton linear accelerator has a triode type electron gun and the modulating anode voltage should be supplied. The klystron has gone through some modification in the modulating anode voltage supply circuit. Formerly, the mod-anode voltage was supplied by using the tetrode-controlled voltage divider. This system requires addition power supply for the tetrode and the grid control circuit. Recently we modified the mod-anode supply from the tetrode-controlled voltage divider to a resistive voltage divider. The resistors for the previous voltage divider were installed at a supporter with high voltage bushing structure next to the klystron. In the previous system, the resistors were exposed to the air and their size was very bulky, length of which was about 1m long. To reduce the space occupied by the voltage divider and to improve the electrical insulation performance, the voltage dividing resistors were moved into the oil tank of the klystron. During the operation of the 20 MeV linac, the klystron parameters were measured. In this paper, the modification of the voltage divider and the operational characteristics of the klystron with modified voltage divider circuit are presented

  20. Mechanical properties of organic composite materials irradiated with 2 MeV electrons

    International Nuclear Information System (INIS)

    Egusa, S.; Kirk, M.A.; Birtcher, R.C.; Argonne National Lab., IL; Hagiwara, M.; Kawanishi, S.

    1983-01-01

    Four kinds of cloth-filled organic composites (filter: glass or carbon fiber; matrix; epoxy or polyimide resin) were irradiated with 2 MeV electrons at room temperature, and were examined with regard to the mechanical properties. Following irradiation the Young's (tensile) modulus of these composites remains practically unchanged even after irradiation up to 15.000 Mrad. The shear modulus and the ultimate strength, on the other hand, begin to decrease after the absorbed dose reaches about 2.000 Mrad for the glass/epoxy composite and about 5.000-10.000 Mrad for the other composites. This result is ascribed to the decrease in the capacity of load transfer from the matrix to the fiber due to the radiation damage at the interface, and the dose dependence is interpreted and formulated based on the mechanics of composite materials and the target theory used in radiation biology. As to the fracture behavior, the propagation energy increases from the beginning of irradiation. This result is attributed to the radiation-induced decrease in the bonding energy at the interface. (orig.)

  1. Effect of cellular glutathione content on the induction of DNA double strand breaks by 25 MeV electrons

    Energy Technology Data Exchange (ETDEWEB)

    Frankenberg, D.; Kistler, M.; Eckhardt-Schupp, F.

    1987-08-01

    The effect of endogenous glutathione (GSH) on the induction of DNA double strand breaks (dsb) by 25 MeV electrons was investigated using stationary haploid yeast cells defective in ..gamma..-glutamyl-cysteine-synthetase (gsh 1) containing less than 5 per cent of the normal GSH content. In gsh 1 cells the induction of dsb is increased by a factor of 1.5 under oxic and 1.8 under anoxic irradiation conditions whereas the oxygen enhancement ratio was only slightly decreased (1.9) compared to wild-type cells (2.4).

  2. Effect of cellular glutathione content on the induction of DNA double strand breaks by 25 MeV electrons

    International Nuclear Information System (INIS)

    Frankenberg, D.; Kistler, M.; Eckhardt-Schupp, F.

    1987-01-01

    The effect of endogenous glutathione (GSH) on the induction of DNA double strand breaks (dsb) by 25 MeV electrons was investigated using stationary haploid yeast cells defective in γ-glutamyl-cysteine-synthetase (gsh 1) containing less than 5 per cent of the normal GSH content. In gsh 1 cells the induction of dsb is increased by a factor of 1.5 under oxic and 1.8 under anoxic irradiation conditions whereas the oxygen enhancement ratio was only slightly decreased (1.9) compared to wild-type cells (2.4). (author)

  3. Enacting laws concerning radiation safety management for students using X-rays and electron beams under 1 MeV

    International Nuclear Information System (INIS)

    Nishizawa, Kunihide; Shibata, Michihiro; Saze, Takuya

    2004-01-01

    Laws concerning radiation safety management were analyzed from the point of view of defining precisely what is meant by radiation and what is meant by the subject. There are no laws to protect students from radiation hazards when using X-rays and electron beams under 1 MeV for research and/or education. The Law concerning Technical Standards for Preventing Radiation Hazards gives the authorities the power to enact new rules and regulations that will protect the students. The Radiation Council must take charge for enactment of all laws regarding radiation safety management. (author)

  4. Linac4 crosses the 100 MeV threshold

    CERN Multimedia

    Corinne Pralavorio

    2016-01-01

    The new linear accelerator, which from 2020 will be the first link in the accelerator chain, has entered a new stage of its commissioning.   Members of the team in charge of the commissioning of Linac4 in the accelerator’s control room. A few hours earlier, Linac4 accelerated a beam to 107 MeV for the first time. We couldn’t have imagined a more appropriate date: on 1 July (1.07), Linac4 reached an energy of 107 MeV. Having crossed the 100 MeV barrier, the linear accelerator is now on the home straight of its commissioning. “This stage was very quick – it took less than two weeks,” says Alessandra Lombardi, deputy project leader of Linac4, in charge of the commissioning. In 2020, Linac4 will replace the existing Linac2 as the first link in the accelerator chain. It will accelerate beams of H- ions (protons surrounded by two electrons) to 160 MeV, compared to 50 MeV with Linac2. The new machine is particularly sophisticated as it comprises...

  5. New readout and data-acquisition system in an electron-tracking Compton camera for MeV gamma-ray astronomy (SMILE-II)

    Energy Technology Data Exchange (ETDEWEB)

    Mizumoto, T., E-mail: mizumoto@cr.scphys.kyoto-u.ac.jp [Department of Physics, Kyoto University, 606-8502 Kyoto (Japan); Matsuoka, Y. [Department of Physics, Kyoto University, 606-8502 Kyoto (Japan); Mizumura, Y. [Unit of Synergetic Studies for Space, Kyoto University, 606-8502 Kyoto (Japan); Department of Physics, Kyoto University, 606-8502 Kyoto (Japan); Tanimori, T. [Department of Physics, Kyoto University, 606-8502 Kyoto (Japan); Unit of Synergetic Studies for Space, Kyoto University, 606-8502 Kyoto (Japan); Kubo, H.; Takada, A.; Iwaki, S.; Sawano, T.; Nakamura, K.; Komura, S.; Nakamura, S.; Kishimoto, T.; Oda, M.; Miyamoto, S.; Takemura, T.; Parker, J.D.; Tomono, D.; Sonoda, S. [Department of Physics, Kyoto University, 606-8502 Kyoto (Japan); Miuchi, K. [Department of Physics, Kobe University, 658-8501 Kobe (Japan); Kurosawa, S. [Institute for Materials Research, Tohoku University, 980-8577 Sendai (Japan)

    2015-11-11

    For MeV gamma-ray astronomy, we have developed an electron-tracking Compton camera (ETCC) as a MeV gamma-ray telescope capable of rejecting the radiation background and attaining the high sensitivity of near 1 mCrab in space. Our ETCC comprises a gaseous time-projection chamber (TPC) with a micro pattern gas detector for tracking recoil electrons and a position-sensitive scintillation camera for detecting scattered gamma rays. After the success of a first balloon experiment in 2006 with a small ETCC (using a 10×10×15 cm{sup 3} TPC) for measuring diffuse cosmic and atmospheric sub-MeV gamma rays (Sub-MeV gamma-ray Imaging Loaded-on-balloon Experiment I; SMILE-I), a (30 cm){sup 3} medium-sized ETCC was developed to measure MeV gamma-ray spectra from celestial sources, such as the Crab Nebula, with single-day balloon flights (SMILE-II). To achieve this goal, a 100-times-larger detection area compared with that of SMILE-I is required without changing the weight or power consumption of the detector system. In addition, the event rate is also expected to dramatically increase during observation. Here, we describe both the concept and the performance of the new data-acquisition system with this (30 cm){sup 3} ETCC to manage 100 times more data while satisfying the severe restrictions regarding the weight and power consumption imposed by a balloon-borne observation. In particular, to improve the detection efficiency of the fine tracks in the TPC from ~10% to ~100%, we introduce a new data-handling algorithm in the TPC. Therefore, for efficient management of such large amounts of data, we developed a data-acquisition system with parallel data flow.

  6. Radiation damage measurements on nonmetals made during irradiation with 1 to 3 MeV electrons. Final Report

    International Nuclear Information System (INIS)

    Levy, P.W.

    1982-01-01

    To investigate the fundamental processes producing radiation damage in nonmetals a unique facility has been developed for making optical absorption, luminescence and other measurements during irradiation with 1 to 3 MeV electrons. Measurements are made with a 13 meter long double beam spectrometer arranged so that all sensitive components, e.g., phototubes, are outside of the irradiation chamber. A computer provdies automatic control and data recording. A 256 point absorption and a 256 point luminescence spectra are recorded as often as every 40 seconds in either the 200-400 or 400-800 mm wavelength range. Samples are irradiated, at temperatures between 20 and 900 C, in an electronically controlled chamber containing He exchange gas and equipped with thin Havar windows to transmit the electron beam and high purity fused silica windows for the spectrophotometer beams. Radiation induced luminescence and absorption in the chamber windows, etc. is eliminated by the double beam spectrophotometer. Studies made with this equipment demonstrate clearly that many of the processes occurring during damage formation are transient

  7. Angular distributions of absorbed dose of Bremsstrahlung and secondary electrons induced by 18-, 28- and 38-MeV electron beams in thick targets.

    Science.gov (United States)

    Takada, Masashi; Kosako, Kazuaki; Oishi, Koji; Nakamura, Takashi; Sato, Kouichi; Kamiyama, Takashi; Kiyanagi, Yoshiaki

    2013-03-01

    Angular distributions of absorbed dose of Bremsstrahlung photons and secondary electrons at a wide range of emission angles from 0 to 135°, were experimentally obtained using an ion chamber with a 0.6 cm(3) air volume covered with or without a build-up cap. The Bremsstrahlung photons and electrons were produced by 18-, 28- and 38-MeV electron beams bombarding tungsten, copper, aluminium and carbon targets. The absorbed doses were also calculated from simulated photon and electron energy spectra by multiplying simulated response functions of the ion chambers, simulated with the MCNPX code. Calculated-to-experimental (C/E) dose ratios obtained are from 0.70 to 1.57 for high-Z targets of W and Cu, from 15 to 135° and the C/E range from 0.6 to 1.4 at 0°; however, the values of C/E for low-Z targets of Al and C are from 0.5 to 1.8 from 0 to 135°. Angular distributions at the forward angles decrease with increasing angles; on the other hand, the angular distributions at the backward angles depend on the target species. The dependences of absorbed doses on electron energy and target thickness were compared between the measured and simulated results. The attenuation profiles of absorbed doses of Bremsstrahlung beams at 0, 30 and 135° were also measured.

  8. Application of calorimeters for 5 MeV EB and bremsstrahlung dosimetry

    DEFF Research Database (Denmark)

    Sato, T.; Takahashi, T.; Saito, T.

    1993-01-01

    Graphite and water calorimeters, which were developed for use a 10 MeV electron beams (EB) at Riso National Laboratory, were used for process validation and routine dosimeter calibration at a 5 MeV EB. Water calorimeters were used for reference measurements for 5 MeV EB, the response was found...... to be directly proportional to the beam current and the variation among three water calorimeters was less than +/- 2 % in the range of 10 to 40 kGy. CTA, PMMA, RCD dosimeters were calibrated by irradiating the dosimeters and water calorimeters Simultaneously. The water calorimeter was proved to be an useful tool...... at 5 MeV EB. Graphite calorimeters gave reproducible readings within 3.3 % relative errors (95 % confidence level) for X-ray measurement....

  9. Application of calorimeters for 5 MeV EB and bremsstrahlung dosimetry

    International Nuclear Information System (INIS)

    Sato, Toshio; Takahashi, Toru; Saito, Toshio; Takehisa, Masaaki; Miller, A.

    1993-01-01

    Graphite and water calorimeters, which were developed for use with 10 MeV electron beams (EB) at Riso National Laboratory, were used for process validation and routine dosimeter calibration at a 5 MeV EB. Water calorimeters were used for reference measurements for 5 MeV EB, the response was found to be directly proportional to the beam current and the variation among three water calorimeters was less than ± 2% in the range of 10 to 40 kGy. CTA PMMA RCD dosimeters were calibrated by irradiating the dosimeters and water calorimeters simultaneously. The water calorimeter was proved to be an useful tool at 5 MeV EB. Graphite calorimeters gave reproducible readings within 3.3 % relative errors (95% confidence level) for X-ray measurement. (Author)

  10. Challenges in designing a very compact 130 MeV Moeller polarimeter for the S-DALINAC

    Energy Technology Data Exchange (ETDEWEB)

    Bahlo, Thore; Enders, Joachim; Kuerzeder, Thorsten; Pietralla, Norbert; Wissmann, Jan [Institut fuer Kernphysik, TU Darmstadt, Darmstadt (Germany)

    2016-07-01

    The Superconducting Darmstadt Linear Accelerator is capable of accelerating polarized electron beams produced by the S-DALINAC Polarized Injector (SPIN). For electron energies of up to 14 MeV it is possible to measure the absolute polarization of the electrons with two Mott polarimeters that are already mounted in the injector beamline. Until now it is not possible to measure the absolute electron beam polarization after the passage of the main accelerator. Therefore a Moeller polarimeter for energies between 50 MeV and 130 MeV is currently being developed. The rather low incident beam energy, the variability of the incident beam energy, and spatial restrictions necessitate a compact set-up with large acceptance. The very restrictive boundary conditions introduce technical and geometrical challenges. We will present the design of the target chamber, of the separation dipole magnet as well as the beam dump.

  11. Narrow electron injector for ballistic electron spectroscopy

    International Nuclear Information System (INIS)

    Kast, M.; Pacher, C.; Strasser, G.; Gornik, E.

    2001-01-01

    A three-terminal hot electron transistor is used to measure the normal energy distribution of ballistic electrons generated by an electron injector utilizing an improved injector design. A triple barrier resonant tunneling diode with a rectangular transmission function acts as a narrow (1 meV) energy filter. An asymmetric energy distribution with its maximum on the high-energy side with a full width at half maximum of ΔE inj =10 meV is derived. [copyright] 2001 American Institute of Physics

  12. XRD study of yttria stabilized zirconia irradiated with 7.3 MeV Fe, 10 MeV I, 16 MeV Au, 200 MeV Xe and 2.2 GeV Au ions

    Energy Technology Data Exchange (ETDEWEB)

    Nakano, K.; Yoshizaki, H. [Department of Materials Science, Osaka Prefecture University, Sakai, Osaka 599-8531 (Japan); Saitoh, Y. [Takasaki Advanced Radiation Research Institute, Japan Atomic Energy Agency, Takasaki, Gunma 370-1292 (Japan); Ishikawa, N. [Tokai Research and Development Center, Tokai-mura, Naka-gun, Ibaraki 319-1195 (Japan); Iwase, A., E-mail: iwase@mtr.osakafu-u.ac.jp [Department of Materials Science, Osaka Prefecture University, Sakai, Osaka 599-8531 (Japan)

    2016-03-01

    To simulate energetic neutron irradiation effects, yttria-stabilized zirconia (YSZ) which is one of the major materials for electrical corrosion potential sensors (ECP sensors) was irradiated with heavy ions at energies ranging from 7.3 MeV to 2.2 GeV. Ion irradiation effects on the lattice structure were analyzed using the X-ray diffraction (XRD). The increase in lattice constant was induced by the ion irradiation. It was dominated by the elastic collision process and not by the electronic excitation process. The lattice disordering which was observed as a broadening of XRD peaks was also induced by the irradiation especially for 200 MeV Xe ion irradiation. The present result suggests that the expansion and/or the disordering of YSZ lattice induced by energetic neutrons may affect the durability of a joint interface between a metal housing and YSZ membrane for the usage of ECP sensors in nuclear power reactors.

  13. Generation of mega-electron-volt electron beams by an ultrafast intense laser pulse

    International Nuclear Information System (INIS)

    Wang Xiaofang; Saleh, Ned; Krishnan, Mohan; Wang Haiwen; Backus, Sterling; Murnane, Margaret; Kapteyn, Henry; Umstadter, Donald; Wang Quandong; Shen Baifei

    2003-01-01

    Mega-electron-volt (MeV) electron emission from the interaction of an ultrafast (τ∼29 fs), intense (>10 18 W/cm 2 ) laser pulse with underdense plasmas has been studied. A beam of MeV electrons with a divergence angle as small as 1 deg. is observed in the forward direction, which is correlated with relativistic filamentation of the laser pulse in plasmas. A novel net-energy-gain mechanism is proposed for electron acceleration resulting from the relativistic filamentation and beam breakup. These results suggest an approach for generating a beam of femtosecond, MeV electrons at a kilohertz repetition rate with a compact ultrafast intense laser system

  14. Radiation self-polarization of electrons moving in a magnetic field. [Vector spin operator, relaxation time

    Energy Technology Data Exchange (ETDEWEB)

    Bagrov, V G; Dorofeev, O F; Sokolov, A A; Ternov, I M; Khalilov, V R [Moskovskij Gosudarstvennyj Univ. (USSR)

    1975-03-11

    When electrons move in a magnetic field, synchrotron radiation gives rise to transitions accompanied by the electron spin reorientation. In this case, it is essential that the transition probability depends on the spin orientation; as a result electron polarization takes place with the spin orientation being predominantly opposite to the direction of the magnetic field. This effect has been called ''radiative self-polarization of electrons''. The present work is concerned with the question how the choice of the spin operator will affect the self-polarization degree and relaxation time. The problem has been solved for a vector spin operator.

  15. Microstructural Parameters in 8 MeV Electron-Irradiated BOMBYX MORI Silk Fibers by Wide-ANGLE X-Ray Scattering Studies (waxs)

    Science.gov (United States)

    Sangappa, Asha, S.; Sanjeev, Ganesh; Subramanya, G.; Parameswara, P.; Somashekar, R.

    2010-01-01

    The present work looks into the microstructural modification in electron irradiated Bombyx mori P31 silk fibers. The irradiation process was performed in air at room temperature using 8 MeV electron accelerator at different doses: 0, 25, 50 and 100 kGy. Irradiation of polymer is used to cross-link or degrade the desired component or to fix the polymer morphology. The changes in microstructural parameters in these natural polymer fibers have been computed using wide angle X-ray scattering (WAXS) data and employing line profile analysis (LPA) using Fourier transform technique of Warren. Exponential, Lognormal and Reinhold functions for the column length distributions have been used for the determination of crystal size, lattice strain and enthalpy parameters.

  16. Design study of a far-infrared free electron laser with a 20 MeV RF linear accelerator

    International Nuclear Information System (INIS)

    Nakata, S.; Tsukishima, C.; Hifumi, T.; Okuda, S.; Sato, S.; Yosojima, Y.

    1991-01-01

    A FEL in the far-infrared region has been designed using a low energy RF linear accelerator. First we estimate a small signal gain from spontaneous emission using the Madey's theorem. In the calculation following effects are included: an actual field distribution (using a measured magnetic field), beam envelope in the phase space through the undulator, energy spread, and electron beam mis-alignment to the undulator axis. We have developed a code which can simulate three dimensional processes of the electron interaction with multi-mode laser fields in the undulator. From this code we could obtain the time dependent bunching process of electrons and amplification of the laser field. During the calculation we assume an electron beam of 20 MeV, 100 mA with a pulse length of 3 μs, and an undulator of 28 periods, 6 cm periodic length and 2.5 kG peak field. The results from these calculations show that the small-signal gain over 40 % can be obtained, but mis-alignment of the beam severely degrades the gain. The results also show that the output power of several MW can be obtained under the above conditions. Considering the simulation results, a FEL beam line was constructed and the beam size at the undulator was measured. And electrons were focused enough for the FEL experiment. (author)

  17. Modifications in the structural and optical properties of nanocrystalline CaWO4 induced by 8 MeV electron beam irradiation

    International Nuclear Information System (INIS)

    Aloysius Sabu, N.; Priyanka, K.P.; Ganesh, Sanjeev; Varghese, Thomas

    2016-01-01

    In this article we report the post irradiation effects in the structural and optical properties of nanocrystalline calcium tungstate synthesized by chemical precipitation and heat treatment. The samples were subjected to different doses of high-energy electron beam obtained from an 8 MeV Microton. Investigations using X-ray diffraction, scanning electron microscopy and Raman spectra confirmed changes in particle size and structural parameters. However, no phase change was detected for irradiated samples. The stretching/compressive strain caused by high energy electrons is responsible for the slight shift in the XRD peaks of irradiated samples. Modifications in the morphology of different samples were confirmed by scanning electron microscopy. Ultraviolet-visible absorption studies showed variations in the optical band gap (4.08–4.25 eV) upon electron-beam irradiation. New photoluminescence behaviour in electron beam irradiated nanocrystalline CaWO 4 was evidenced. A blue shift of the PL peak with increase in intensity was observed in all the irradiated samples. - Highlights: • Calcium tungstate nanocrystals are synthesized by simple chemical precipitation method. • Electron beam induced modifications in the structural and optical properties are investigated. • New photoluminescence behaviour is evidenced due to beam irradiation.

  18. Influence of boundary effects on electron beam dose distribution formation in multilayer targets

    International Nuclear Information System (INIS)

    Kaluska, I.; Zimek, Z.; Lazurik, V.T.; Lazurik, V.M.; Popov, G.F.; Rogov, Y.V.

    2010-01-01

    Computational dosimetry play a significant role in an industrial radiation processing at dose measurements in the product irradiated with electron beams (EB), X-ray and gamma ray from radionuclide sources. Accurate and validated programs for absorbed dose calculations are required for computational dosimetry. The program ModeStEB (modelling of EB processing in a three-dimensional (3D) multilayer flat targets) was designed specially for simulation and optimization of industrial radiation processing, calculation of the 3D absorbed dose distribution within multilayer packages. The package is irradiated with scanned EB on an industrial radiation facility that is based on the pulsed or continuous type of electron accelerators in the electron energy range from 0.1 to 25 MeV. Simulation of EB dose distributions in the multilayer targets was accomplished using the Monte Carlo (MC) method. Experimental verification of MC simulation prediction for EB dose distribution formation in a stack of plates interleaved with polyvinylchloride (PVC) dosimetric films (DF), within a packing box, and irradiated with a scanned 10 MeV EB on a moving conveyer is discussed. (authors)

  19. The influence of structure depth on image blurring of micrometres-thick specimens in MeV transmission electron imaging.

    Science.gov (United States)

    Wang, Fang; Sun, Ying; Cao, Meng; Nishi, Ryuji

    2016-04-01

    This study investigates the influence of structure depth on image blurring of micrometres-thick films by experiment and simulation with a conventional transmission electron microscope (TEM). First, ultra-high-voltage electron microscope (ultra-HVEM) images of nanometer gold particles embedded in thick epoxy-resin films were acquired in the experiment and compared with simulated images. Then, variations of image blurring of gold particles at different depths were evaluated by calculating the particle diameter. The results showed that with a decrease in depth, image blurring increased. This depth-related property was more apparent for thicker specimens. Fortunately, larger particle depth involves less image blurring, even for a 10-μm-thick epoxy-resin film. The quality dependence on depth of a 3D reconstruction of particle structures in thick specimens was revealed by electron tomography. The evolution of image blurring with structure depth is determined mainly by multiple elastic scattering effects. Thick specimens of heavier materials produced more blurring due to a larger lateral spread of electrons after scattering from the structure. Nevertheless, increasing electron energy to 2MeV can reduce blurring and produce an acceptable image quality for thick specimens in the TEM. Copyright © 2016 Elsevier Ltd. All rights reserved.

  20. Characterization of 10 MeV electron linac for radiation processing

    International Nuclear Information System (INIS)

    Petwal, V.C.; Rao, J.N.; Kaul, A.; Bapna, S.C.; Mulchandani, J.K.; Wanmode, Y.; Pandiyar, M.; Srivastava, P.; Jain, Akhilesh; Hanurkar, P.R.

    2006-01-01

    A radiation processing facility based on a 10 MeV LINAC is being set-up at RRCAT. In the course of commissioning various experiments have been carried-out to characterize the radiation field generated by the accelerator and subsequently to derive the operating parameters of the facility for radiation processing of various items. Results of the experiments are presented in the paper. (author)

  1. Simulation of MeV electron energy deposition in CdS quantum dots absorbed in silicate glass for radiation dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Baharin, R; Hobson, P R; Smith, D R, E-mail: ruzalina.baharin@brunel.ac.u [Centre for Sensors and Instrumentation, School of Engineering and Design, Brunel University, Uxbridge UB8 3PH (United Kingdom)

    2010-09-01

    We are currently developing 2D dosimeters with optical readout based on CdS or CdS/CdSe core-shell quantum-dots using commercially available materials. In order to understand the limitations on the measurement of a 2D radiation profile the 3D deposited energy profile of MeV energy electrons in CdS quantum-dot-doped silica glass have been studied by Monte Carlo simulation using the CASINO and PENELOPE codes. Profiles for silica glass and CdS quantum-dot-doped silica glass were then compared.

  2. Simulation of MeV electron energy deposition in CdS quantum dots absorbed in silicate glass for radiation dosimetry

    International Nuclear Information System (INIS)

    Baharin, R; Hobson, P R; Smith, D R

    2010-01-01

    We are currently developing 2D dosimeters with optical readout based on CdS or CdS/CdSe core-shell quantum-dots using commercially available materials. In order to understand the limitations on the measurement of a 2D radiation profile the 3D deposited energy profile of MeV energy electrons in CdS quantum-dot-doped silica glass have been studied by Monte Carlo simulation using the CASINO and PENELOPE codes. Profiles for silica glass and CdS quantum-dot-doped silica glass were then compared.

  3. A Compact 5 MeV S-Band Electron Linac Based X-Ray Source for Industrial Radiography

    CERN Document Server

    Auditore, Lucrezia; De Pasquale, Domenico; Emanuele, Umberto; Italiano, Antonio; Trifirò, Antonio; Trimarchi, Marina

    2005-01-01

    A compact and reliable X-ray source, based on a 5 MeV, 1 kW, S-band electron linac, has been set up at the Dipartimento di Fisica, Universit\\'a di Messina. This source, coupled with a GOS scintillator screen and a CCD camera, represents an innovative transportable system for industrial radiography and X-ray tomography. Optimization of the parameters influencing the e-gamma conversion and the X-ray beam characteristics have been studied by means of the MCNP-4C2 code. The converter choice is the result of the study of the e-gamma conversion performances for different materials and materials thicknesses. Also the converter position with respect to the linac exit window was studied. The chosen converter consists in a Ta-Cu target inserted close to the linac window. The Cu layer acts as a filter both on the electrons from the source and on the low energy X-rays. The X-ray beam angular profile was studied by means of GafChromic films with and without collimation. In the final source project, a collimation system pr...

  4. Absorbed Dose Distributions in Small Copper Wire Insulation due to Multiple-Sided Irradiations by 0.4 MeV Electrons

    DEFF Research Database (Denmark)

    Miller, Arne; McLaughlin, W. L.; Pedersen, Walther Batsberg

    1979-01-01

    When scanned electron beams are used to crosslink polymeric insulation of wire and cable, an important goal is to achieve optimum uniformity of absorbed dose distributions. Accurate measurements of dose distributions in a plastic dosimeter simulating a typical insulating material (polyethylene......) surrounding a copper wire core show that equal irradiations from as few as four sides give approximately isotropy and satisfactorily uniform energy depositions around the wire circumference. Electron beams of 0.4 MeV maximum energy were used to irradiate wires having a copper core of 1.0 mm dia....... and insulation thicknesses between 0.4 and 0.8 mm. The plastic dosimeter simulating polyethylene insulations was a thin radiochromic polyvinyl butyral film wrapped several times around the copper wire, such that when unwrapped and analyzed optically on a scanning microspectrophotometer, high-resolution radial...

  5. Dose-response relationship for chromosomal aberrations induced in human lymphocytes by 18 MeV electron beam irradiation

    International Nuclear Information System (INIS)

    Lashin, E.A.; Elaasar, E.M.; Moustafa, H.F.; Bakir, Y.Y.; Al Zenki, S.D.

    1990-01-01

    Dose response curves for lymphocyte chromosome aberration frequencies using X- and gamma radiation became an important and reliable indicator as biological dosimeter especially in radiation accidents and occupational over exposures. Nowadays electron beam therapy is frequently used for their advantages in cases of tumours under or near to the body surface. Dose-response curves for these electron beams are rarely published. Human peripheral blood lymphocytes were in vitro irradiated with various low and high doses (0.1 Gy to 4.9 Gy) of 18 MeV electron beams to utilize such a dose-response curve using chromosomal aberration frequencies as a biological indicator. Then we compared the biological curve with physically obtained curves normally used in planning for radiotherapy treatment. It is interesting to find a significant difference between both of them. The biological curve is generally higher in value and the aberrations induced by 93% of a dose is significantly higher and deeper in site than those aberrations induced by the 100% dose calculated physically. If the above observation is confirmed by detailed studies, it would be of importance to the radiotherapist to plan for isodose curves according to biological determinations. (author)

  6. Effects produced in GaAs by MeV ion bombardment

    International Nuclear Information System (INIS)

    Wie, C.R.

    1985-01-01

    The first part of this thesis presents work performed on the ionizing energy beam induced adhesion enhancement of thin (approx.500 A) Au films on GaAs substrates. The ionizing beam, employed in the present thesis, is the MeV ions (i.e., 16 O, 19 F, and 35 Cl), with energies between 1 and 20 MeV. Using the Scratch test for adhesion measurement, and ESCA for chemical analysis of the film substrate interface, the native oxide layer at the interface is shown to play an important role in the adhesion enhancement by the ionizing radiation. A model is discussed that explains the experimental data on the dependence of adhesion enhancement on the energy which was deposited into electronic processes at the interface. The second part of the thesis presents research results on the radiation damage in GaAs crystals produced by MeV ions. Lattice parameter dilatation in the surface layers of the GaAs crystals becomes saturated after a high dose bombardment at room temperature. The strain produced by nuclear collisions is shown to relax partially due to electronic excitation (with a functional dependence on the nuclear and electronic stopping power of bombarding ions. Data on the GaAs and GaP crystals suggest that low temperature recovery stage defects produce major crystal distortion

  7. Construction and operation of a 10 MeV electron accelerator and associated experimental facilities at Brookhaven National Laboratory, Upton, New York. Environmental assessment

    International Nuclear Information System (INIS)

    1994-02-01

    The purpose of this environmental impact statement is to determine whether there would be significant environmental impacts associated with the construction of an experimental facility at Brookhaven National Laboratory for radiation chemistry research and operation of the 10-MeV electron accelerator proposed for it. The document describes the need for action, alternative actions, the affected environment, and potential environmental impacts

  8. Observation of transverse and longitudinal modes in non-neutral electron clouds confined in a magnetic mirror

    International Nuclear Information System (INIS)

    Eckhouse, S.; Fisher, A.; Rostoker, N.

    1979-01-01

    Electrostatic modes on non-neutral electron clouds confined in a magnetic mirror field have been investigated. The cloud contains 2 x 10 11 electrons at an average kinetic energy of 0.3 MeV for a magnetic field with a peak intensity of 9 kG at the midplane. It was found that the cloud is moving azimuthally as well as longitudinally. The azimuthal motion has an m=1 spatial nature. The longitudinal modes have a more complicated nature, but their frequency equals that of the azimuthal mode

  9. INCLUSIVE SYSTEMATICS FOR SI-28+SI-28 REACTIONS BETWEEN 20 AND 35 MEV PER NUCLEON

    NARCIS (Netherlands)

    BOX, PF; GRIFFIOEN, KA; DECOWSKI, P; BOOTSMA, T; GIERLIK, E; VANNIEUWENHUIZEN, GJ; TWENHOFEL, C; KAMERMANS, R; WILSCHUT, HW; GIORNI, A; MORAND, C; DEMEYER, A; GUINET, D

    Inclusive velocity spectra of heavy ions produced in the Si-28 + Si-28 reaction at 22, 26, 30, and 35 MeV per nucleon were measured and decomposed into peripheral and central components using an analytical moving-source parametrization. The persistence of incomplete fusion followed by evaporation

  10. The influence of the electron wave function on the Pt Lsub(I) and Lsub(III) ionization probabilities by 3.6 MeV He impact

    International Nuclear Information System (INIS)

    Ullrich, J.; Dangendorf, V.; Dexheimer, K.; Do, K.; Kelbch, C.; Kelbch, S.; Schadt, W.; Schmidt-Boecking, H.; Stiebing, K.E.; Roesel, F.; Trautmann, D.

    1986-01-01

    For 3.6 MeV He impact the Lsub(I) and Lsub(III) subshell ionization probabilities of Pt have been measured. Due to relativistic effects in the electron wave functions, the Lsub(I) subshell ionization probability Isub(LI)(b) is strong enhanced at small impact parameters exceeding even Isub(LIII)(b) in nice agreement with the SCA theory. (orig.)

  11. Bunch-shape monitor for a picosecond single-bunch beam of a 35 MeV electron linear accelerator

    International Nuclear Information System (INIS)

    Hosono, Yoneichi; Nakazawa, Masaharu; Iguchi, Tetsuo

    1995-01-01

    A non-interactive-type bunch-shape and beam intensity monitor for a 35 MeV electron linear accelerator (linac) has been developed. The monitor consists of an electric SMA-type connector and an Al pipe of 50 mm inner diameter. Test measurements of the present monitor have been made under the conditions of the accelerated charges of lower than 27 nC/pulse and the pulse width ranging from 6 to 30 ps (Full Width at Half Maximum). The results show that the present monitor is applicable to bunch-shape measurement of the picosecond single-bunch beam. The monitor output is also found to be proportional to the beam intensity of more than 0.05 nC/pulse. (author)

  12. Peculiarities of the coherent spontaneous synchrotron radiation of dense electron bunches

    International Nuclear Information System (INIS)

    Balal, N.; Bratman, V. L.; Savilov, A. V.

    2014-01-01

    In a short section of homogeneous magnetic field, quasi-plane electron bunches from linear accelerators with laser-driven photo-injectors at moderate particle energies can generate strongly directed, very short and powerful terahertz electromagnetic pulses with a broad frequency spectrum. The formulas for radiation fields, their spectra and efficiency of radiation are presented in a very simple analytical form using expressions for the fields of an arbitrary moving charged plane. The self-action and mutual interaction of thin electron layers are estimated. It is shown that the radiation with frequencies of up to (1–3) THz can be effectively generated by electrons with energies (4–6) MeV in a short and relatively weak magnetic field of (4–10) kOe

  13. Peculiarities of the coherent spontaneous synchrotron radiation of dense electron bunches

    Energy Technology Data Exchange (ETDEWEB)

    Balal, N. [Ariel University, Ariel (Israel); Bratman, V. L. [Institute of Applied Physics, Russian Academy of Sciences, Nizhny Novgorod (Russian Federation); Savilov, A. V., E-mail: savilov@appl.sci-nnov.ru [Institute of Applied Physics, Russian Academy of Sciences, Nizhny Novgorod (Russian Federation); Lobachevsky State University of Nizhny Novgorod, Nizhny Novgorod (Russian Federation)

    2014-02-15

    In a short section of homogeneous magnetic field, quasi-plane electron bunches from linear accelerators with laser-driven photo-injectors at moderate particle energies can generate strongly directed, very short and powerful terahertz electromagnetic pulses with a broad frequency spectrum. The formulas for radiation fields, their spectra and efficiency of radiation are presented in a very simple analytical form using expressions for the fields of an arbitrary moving charged plane. The self-action and mutual interaction of thin electron layers are estimated. It is shown that the radiation with frequencies of up to (1–3) THz can be effectively generated by electrons with energies (4–6) MeV in a short and relatively weak magnetic field of (4–10) kOe.

  14. High-quality beam generation using an RF gun and a 150 MeV microtron

    Science.gov (United States)

    Kuroda, R.; Washio, M.; Kashiwagi, S.; Kobuki, T.; Ben-Zvi, I.; Wang, X. J.; Hori, T.; Sakai, F.; Tsunemi, A.; Urakawa, J.; Hirose, T.

    2000-11-01

    Low-emittance sub-picosecond electron pulses are expected to be used in a wide field, such as free electron laser, laser acceleration, femtosecond X-ray generation by Inverse Compton scattering, pulse radiolysis, etc. In order to produce the low-emittance sub-picosecond electron pulse, we are developing a compact Racetrack Microtron (RTM) with a new 5 MeV injection system adopting a laser photo cathode RF gun (Washio et al., Seventh China-Japan Bilateral Symposium on Radiation Chemistry, October 28, Cengdu, China, 1996). The operation of RTM has been kept under a steady state of beam loading for long pulse mode so far (Washio et al., J. Surf. Sci. Soc. Jpn. 19 (2) (1998) 23). In earlier work (Washio et al., PAC99, March 31, New York, USA, 1999), we have succeeded in the numerical simulation for the case of single short pulse acceleration. Finally, the modified RTM was demonstrated as a useful accelerator for a picosecond electron pulse generation under a transient state of beam loading. In the simulation, a picosecond electron pulse was accelerated to 149.6 MeV in RTM for the injection of 5 MeV electron bunch with a pulse length of 10 ps (FWHM), a charge of 1 nC per pulse, and an emittance of 3 πmm mrad.

  15. Electronic structure and electron dynamics at Si(100)

    Energy Technology Data Exchange (ETDEWEB)

    Weinelt, M. [Universitaet Erlangen-Nuernberg, Lehrstuhl fuer Festkoerperphysik, Erlangen (Germany); Max-Born-Institut, Berlin (Germany); Kutschera, M.; Schmidt, R.; Orth, C.; Fauster, T. [Universitaet Erlangen-Nuernberg, Lehrstuhl fuer Festkoerperphysik, Erlangen (Germany); Rohlfing, M. [International University Bremen, School of Engineering and Science, P.O. Box 750 561, Bremen (Germany)

    2005-02-01

    The electronic structure and electron dynamics at a Si(100) surface is studied by two-photon photoemission (2PPE). At 90 K the occupied D{sub up} dangling-bond state is located 150{+-}50 meV below the valence-band maximum (VBM) at the center of the surface Brillouin zone anti {gamma} and exhibits an effective hole mass of (0.5{+-}0.15)m{sub e}. The unoccupied D{sub down} band has a local minimum at anti {gamma} at 650{+-}50 meV above the VBM and shows strong dispersion along the dimer rows of the c(4 x 2) reconstructed surface. At 300 K the D{sub down} position shifts comparable to the Si conduction-band minimum by 40 meV to lower energies but the dispersion of the dangling-bond states is independent of temperature. The surface band bending for p-doped silicon is less than 30 meV, while acceptor-type defects cause significant and preparation-dependent band bending on n-doped samples. 2PPE spectra of Si(100) are dominated by interband transitions between the occupied and unoccupied surface states and emission out of transiently and permanently charged surface defects. Including electron-hole interaction in many-body calculations of the quasi-particle band structure leads us to assign a dangling-bond split-off state to a quasi-one-dimensional surface exciton with a binding energy of 130 meV. Electrons resonantly excited to the unoccupied D{sub down} dangling-bond band with an excess energy of about 350 meV need 1.5{+-}0.2 ps to scatter via phonon emission to the band bottom at anti {gamma} and relax within 5 ps with an excited hole in the occupied surface band to form an exciton living for nanoseconds. (orig.)

  16. Small-sized linear accelerator of 2.5 MeV electrons with a local radiation shield for custom examination of freight transported by motor transport

    International Nuclear Information System (INIS)

    Baklanov, A.V.; Gavrish, Yu.N.; Klinov, A.P.; Krest'yaninov, A.S.; Nikolaev, V.M.; Fomin, L.P.; Linkenbach, H.A.; Geus, G.; Knospel, W.

    2001-01-01

    A new development of a small-sized linear accelerator of 2.5 MeV electrons with a local radiation protection is described. The accelerator is intended for movable facilities of radiation custom of the freight transported by motor transport. Main constructive solutions, mass and dimension characteristics and results of preliminary tests of the accelerator parameters and characteristics of radiation protection are presented [ru

  17. Comparison of measured with calculated dose distribution from a 120-MeV electron beam from a laser-plasma accelerator

    International Nuclear Information System (INIS)

    Lundh, O.; Rechatin, C.; Faure, J.; Ben-Ismaïl, A.; Lim, J.; De Wagter, C.; De Neve, W.; Malka, V.

    2012-01-01

    Purpose: To evaluate the dose distribution of a 120-MeV laser-plasma accelerated electron beam which may be of potential interest for high-energy electron radiation therapy. Methods: In the interaction between an intense laser pulse and a helium gas jet, a well collimated electron beam with very high energy is produced. A secondary laser beam is used to optically control and to tune the electron beam energy and charge. The potential use of this beam for radiation treatment is evaluated experimentally by measurements of dose deposition in a polystyrene phantom. The results are compared to Monte Carlo simulations using the geant4 code. Results: It has been shown that the laser-plasma accelerated electron beam can deliver a peak dose of more than 1 Gy at the entrance of the phantom in a single laser shot by direct irradiation, without the use of intermediate magnetic transport or focusing. The dose distribution is peaked on axis, with narrow lateral penumbra. Monte Carlo simulations of electron beam propagation and dose deposition indicate that the propagation of the intense electron beam (with large self-fields) can be described by standard models that exclude collective effects in the response of the material. Conclusions: The measurements show that the high-energy electron beams produced by an optically injected laser-plasma accelerator can deliver high enough dose at penetration depths of interest for electron beam radiotherapy of deep-seated tumors. Many engineering issues must be resolved before laser-accelerated electrons can be used for cancer therapy, but they also represent exciting challenges for future research.

  18. Design of 6 MeV X-band electron linac for dual-head gantry radiotherapy system

    Science.gov (United States)

    Shin, Seung-wook; Lee, Seung-Hyun; Lee, Jong-Chul; Kim, Huisu; Ha, Donghyup; Ghergherehchi, Mitra; Chai, Jongseo; Lee, Byung-no; Chae, Moonsik

    2017-12-01

    A compact 6 MeV electron linac is being developed at Sungkyunkwan University, in collaboration with the Korea atomic energy research institute (KAERI). The linac will be used as an X-ray source for a dual-head gantry radiotherapy system. X-band technology has been employed to satisfy the size requirement of the dual-head gantry radiotherapy machine. Among the several options available, we selected a pi/2-mode, standing-wave, side-coupled cavity. This choice of radiofrequency (RF) cavity design is intended to enhance the shunt impedance of each cavity in the linac. An optimum structure of the RF cavity with a high-performance design was determined by applying a genetic algorithm during the optimization procedure. This paper describes the detailed design process for a single normal RF cavity and the entire structure, including the RF power coupler and coupling cavity, as well as the beam dynamics results.

  19. Study of the /sup 12/N 2. 43 MeV level. [Differential cross sections; 44 MeV /sup 3/He; 52 MeV p

    Energy Technology Data Exchange (ETDEWEB)

    Cecil, F E; Shepard, J R; Sercely, R R; Peterson, R J [Colorado Univ., Boulder (USA). Nuclear Physics Lab.; King, N S.P. [California Univ., Davis (USA). Crocker Nuclear Lab.

    1976-10-11

    The differential cross sections have been measured for the reactions /sup 12/C(/sup 3/He, /sup 3/He')/sup 12/C(17.77 MeV 0/sup +/ T = 1) and /sup 12/C(/sup 3/He, t)/sup 12/N(2.43 MeV) at Esub(/sup 3/He) = 44 MeV. The similar shapes of the angular distributions and the relative magnitudes of the cross sections suggest that the /sup 12/N 2.43 MeV level is the 0/sup +/ T = 1 analog to the /sup 12/C 17.77 MeV level. The reaction /sup 14/N(p, t)/sup 12/N(2.43 MeV) at Esub(p) = 52 MeV is also studied. The strength with which this level is excited in this reaction is consistent with reasonable two-step calculations assuming the 2.43 MeV level to have Jsup(..pi..) = 0/sup +/.

  20. Novel digital K-edge imaging system with transition radiation from an 855-MeV electron beam

    CERN Document Server

    Hagenbuck, F; Clawiter, N; Euteneuer, H; Görgen, F; Holl, P; Johann, K; Kiser, K H; Kemmer, J; Kerschner, T; Kettig, O; Koch, H; Kube, G; Lauth, W; Mauhay, H; Schütrumpf, M; Stotter, R; Strüder, L; Walcher, T; Wilms, A; von Zanthier, C; Zemter, M

    2001-01-01

    A novel K-edge imaging method has been developed at the Mainz Microtron MAMI aiming at a very efficient use of the transition radiation (TR) flux generated by the external 855-MeV electron beam in a foil stack. A fan-like quasi-monochromatic hard X-ray beam is produced from the +or-1-mrad-wide TR cone with a highly oriented pyrolytic graphite (HOPG) crystal. The absorption of the object in front of a 30 mm*10 mm pn charge-coupled device (pn-CCD) photon detector is measured at every pixel by a broad-band energy scan around the K-absorption edge. This is accomplished by a synchronous variation of the lateral crystal position and the electron beam direction which defines also the direction of the TR cone. The system has been checked with a phantom consisting of a 2.5- mu m thick molybdenum sample embedded in a 136- or 272- mu m-thick copper bulk foil. A numerical analysis of the energy spectrum for every pixel demonstrates that data as far as +or-0.75 keV away from the K edge of molybdenum at 20 keV still improv...

  1. ESR response of powder samples of clear fused quartz material to high doses of 10 MeV electrons: possible applications for industrial radiation processing

    International Nuclear Information System (INIS)

    Aliabadi, R.; Amraei, R.; Ranjbar, A.H.; Rafieian, Sh.; Nasirimoghadam, S.

    2010-01-01

    Powder samples of clear fused quartz were irradiated by 10 MeV electrons at doses between 6-15 kGy and 25-37 kGy and analyzed with electron spin resonance. The reproducibility of the material dose response curve was studied, in which the irradiated samples were annealed and reused for further investigations. Results indicate a good linearity between the absorbed dose and the ESR intensity of the signals. They also showed that in the reuse processes, the electron spin resonance signal intensity, in both dose ranges was decreased. The thermal fading represented a relative sharp decay at room temperature through 15 days, after which the decay-rate was negligible for a measurement period of 60 days.

  2. Neutron yield and induced radioactivity: a study of 235-MeV proton and 3-GeV electron accelerators

    International Nuclear Information System (INIS)

    Hsu, Yung-Cheng; Lai, Bo-Lun; Sheu, Rong-Jiun

    2016-01-01

    This study evaluated the magnitude of potential neutron yield and induced radioactivity of two new accelerators in Taiwan: a 235-MeV proton cyclotron for radiation therapy and a 3-GeV electron synchrotron serving as the injector for the Taiwan Photon Source. From a nuclear interaction point of view, neutron production from targets bombarded with high-energy particles is intrinsically related to the resulting target activation. Two multi-particle interaction and transport codes, FLUKA and MCNPX, were used in this study. To ensure prediction quality, much effort was devoted to the associated benchmark calculations. Comparisons of the accelerators' results for three target materials (copper, stainless steel and tissue) are presented. Although the proton-induced neutron yields were higher than those induced by electrons, the maximal neutron production rates of both accelerators were comparable according to their respective beam outputs during typical operation. Activation products in the targets of the two accelerators were unexpectedly similar because the primary reaction channels for proton- and electron-induced activation are (p,pn) and (γ,n), respectively. The resulting residual activities and remnant dose rates as a function of time were examined and discussed. (authors)

  3. Development in Electronic Packaging – Moving to 3D System Configuration

    Directory of Open Access Journals (Sweden)

    I. Szendiuch

    2011-04-01

    Full Text Available The electronic industry is reducing package dimensions of components as well as complete electronics systems. Surface mount device passives and semiconductor chips have to be mounted together bringing a functional system that must realize the required function with necessary reliability and acceptable price. To make up a reliable and cost effective system, the size and weight is being reduced by employing lower voltages and higher speeds. For example, the typical size of SMD passives 30 years ago was 1206 when they were first introduced. Generally, all components including electrical joints are becoming miniaturized and smaller. The industry is moving toward a reduced size of 0201 and 01005 for passives, new fine pitch packages for actives, but the PCB now feature limits for further integration. System on Package (SOP is one way to reach the three-dimensional package concept where components will be placed in three-dimensional configuration. A similar concepts are “Package on Package” (PoP or ”Package in Package” (PiP.

  4. The operational procedure of an electron beam accelerator

    International Nuclear Information System (INIS)

    Lee, Byung Cheol; Choi, Hwa Lim; Yang, Ki Ho; Han, Young Hwan; Kim, Sung Chan

    2008-12-01

    The KAERI(Korea Atomic Energy of Research Institute) high-power electron beam irradiation facility, operating at the energies between 0.3 MeV and 10 MeV, has provided irradiation services to users in industries, universities, and institute in various fields. This manual is for the operation of an electron beam which is established in KAERI, and describes elementary operation procedures of electron beam between 0.3 Mev and 10 MeV. KAERI Electron Accelerator facility(Daejeon, Korea) consists of two irradiators: one is a low-energy electron beam irradiator operated by normal conducting RF accelerator, the other is medium-energy irradiator operated by superconducting RF accelerator. We explain the check points of prior to operation, operation procedure of this facility and the essential parts of electron beam accelerator

  5. The operational procedure of an electron beam accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Byung Cheol; Choi, Hwa Lim; Yang, Ki Ho; Han, Young Hwan; Kim, Sung Chan

    2008-12-15

    The KAERI(Korea Atomic Energy of Research Institute) high-power electron beam irradiation facility, operating at the energies between 0.3 MeV and 10 MeV, has provided irradiation services to users in industries, universities, and institute in various fields. This manual is for the operation of an electron beam which is established in KAERI, and describes elementary operation procedures of electron beam between 0.3 Mev and 10 MeV. KAERI Electron Accelerator facility(Daejeon, Korea) consists of two irradiators: one is a low-energy electron beam irradiator operated by normal conducting RF accelerator, the other is medium-energy irradiator operated by superconducting RF accelerator. We explain the check points of prior to operation, operation procedure of this facility and the essential parts of electron beam accelerator.

  6. Observation of enhanced zero-degree binary encounter electron production with decreasing charge-state q in 30 MeV Oq+ + O2 collisions

    International Nuclear Information System (INIS)

    Zouros, T.J.M.; Wong, K.L.; Hidmi, H.I.

    1993-01-01

    We have measured binary encounter electron production in collisions of 30 MeV O q+ projectiles (q=4-8) and O 2 targets. Measured double differential BEe cross-sections are found to increase with decreasing charge-state q, in agreement with similar previously reported zero-degree investigations for H 2 and He targets. However, measurements for the same system but at 25 degrees shows the opposite trend, that BEe cross sections decrease slightly with decreasing charge state

  7. Effect of fission fragment on thermal conductivity via electrons with an energy about 0.5 MeV in fuel rod gap

    Directory of Open Access Journals (Sweden)

    F Golian

    2017-02-01

    Full Text Available The heat transfer process from pellet to coolant is one of the important issues in nuclear reactor. In this regard, the fuel to clad gap and its physical and chemical properties are effective factors on heat transfer in nuclear fuel rod discussion. So, the energy distribution function of electrons with an energy about 0.5 MeV in fuel rod gap in Busherhr’s VVER-1000 nuclear reactor was investigated in this paper. Also, the effect of fission fragments such as Krypton, Bromine, Xenon, Rubidium and Cesium on the electron energy distribution function as well as the heat conduction via electrons in the fuel rod gap have been studied. For this purpose, the Fokker- Planck equation governing the stochastic behavior of electrons in absorbing gap element has been applied in order to obtain the energy distribution function of electrons. This equation was solved via Runge-Kutta numerical method. On the other hand, the electron energy distribution function was determined by using Monte Carlo GEANT4 code. It was concluded that these fission fragments have virtually insignificant effect on energy distribution of electrons and therefore, on thermal conductivity via electrons in the fuel to clad gap. It is worth noting that this result is consistent with the results of other experiments. Also, it is shown that electron relaxation in gap leads to decrease in thermal conductivity via electrons

  8. Preliminary investigations on high energy electron beam tomography

    Energy Technology Data Exchange (ETDEWEB)

    Baertling, Yves; Hoppe, Dietrich; Hampel, Uwe

    2010-12-15

    In computed tomography (CT) cross-sectional images of the attenuation distribution within a slice are created by scanning radiographic projections of an object with a rotating X-ray source detector compound and subsequent reconstruction of the images from these projection data on a computer. CT can be made very fast by employing a scanned electron beam instead of a mechanically moving X-ray source. Now this principle was extended towards high-energy electron beam tomography with an electrostatic accelerator. Therefore a dedicated experimental campaign was planned and carried out at the Budker Institute of Nuclear Physics (BINP), Novosibirsk. There we investigated the capabilities of BINP's accelerators as an electron beam generating and scanning unit of a potential high-energy electron beam tomography device. The setup based on a 1 MeV ELV-6 (BINP) electron accelerator and a single detector. Besides tomographic measurements with different phantoms, further experiments were carried out concerning the focal spot size and repeat accuracy of the electron beam as well as the detector's response time and signal to noise ratio. (orig.)

  9. Microwave source development for 9 MeV RF electron LINAC for cargo scanning

    International Nuclear Information System (INIS)

    Yadav, V.; Chandan, Shiv; Tillu, A.R.; Bhattacharjee, D.; Chavan, R.B.; Dixit, K.P.; Mittal, K.C.; Gantayet, L.M.

    2011-01-01

    For cargo scanning, high energy X-rays are required. These X-rays can be generated from accelerated electrons. A 9 MeV Cargo scanning RF LINAC has been developed at ECIL, Hyderabad. The Microwave power source required for RF Linac is a klystron-based system generating 5.5 MW peak, 10 kW average, at 2.856 GHz. Various components required for microwave source were identified, procured, tested and integrated into the source. Microwave source was tested on water load, then it was connected to LINAC and RF conditioning and e-beam trials were successfully done. For operating the microwave source, a PC based remote handling system was also designed and developed for operating various power supplies and instruments of the microwave source, including the Klystron modulator, Signal generator and other devices. The accelerator operates in pulse mode, requiring synchronous operation of the Klystron modulator, RF driver amplifier and E-gun modulator. For this purpose, a synchronous trigger generator was designed and developed. This paper describes the development and testing of microwave source and its remote operating system. The results of beam trials are also discussed in this paper. (author)

  10. Measurement of charge composition of electron flows with an energy above hundreds MeV in inner radiaion belt

    International Nuclear Information System (INIS)

    Gusev, A.A.; Pugacheva, G.I.

    1990-01-01

    A detector for studying the charge composition of a high-energy electron component of an internal radiation belt when measuring the precipitation of charged particles in the region of Brazil magnetic anomaly is suggested. The detector is a telescope consisting of two semiconductors and CsI crystal housed into a protection detector in the form of a cup made of plastic scintillator. An absorber of plastic scintillator is placed between semiconductive detections. The detector may record positrons with energy up to 5 MeV in the composition of precipitating particles from the belt in definite detector signal combination and specific energy release 511 keV in CsI crystal. 16 refs.; 3 figs

  11. Reduction of dose enhancement from backscattered radiation at tissue-metal interfaces irradiated with 6MeV electrons

    International Nuclear Information System (INIS)

    Steel, B.

    1996-01-01

    Due to Electron Back Scatter (EBS), electron irradiation of tissue having under lying lead shielding results in an increase in dose to the tissue on the entrance side of the lead. In these situations dose increases as high as 80% have been reported in the literature. Saunders (British Journal of Radiology, 47, 467-470) noted that dose enhancement is dependent on atomic number of the under lying material approximately as Z 0.5 , and it increases at lower incident electron energies. In our clinic we use 2mm of lead shielding to protect under lying normal tissue when 6MeV electrons are used to treat lips and ears. The object of this study was to find the thinnest combination of materials to reduce the total dose to an acceptable level, with the provisos that; the patient does not come into contact with the lead or other metals, the finished shield could comfortabley be placed between the patient's lip and teeth, and that the materials are sufficietly malleable to work into custom shields. Various combinations of dental wax and aluminium were trialed. That which proved to give the best compromise between reduction of EBS and total shielding thickness was, 1mm of aluminim on the beam side of the lead with 1mm of dental wax to completely enclose the shield. In practice the manufactured shields are approximately 6 mm thick, and are usually not uncomfortable for the patient. (author)

  12. Plasma production for the 50 MeV plasma lens experiment at LBL

    International Nuclear Information System (INIS)

    Leemans, W.; van der Geer, B.; de Loos, M.; Conde, M.; Govil, R.; Chattopadhyay, S.

    1994-06-01

    The Center for Beam Physics at LBL has constructed a Beam Test Facility (BTF) housing a 50 MeV electron beam transport line, which uses the linac injector from the Advanced Light Source, and a terawatt Ti:Al 2 O 3 laser system. The linac operates at 50 MeV and generates 15 ps long electron bunches containing a charge of up to 2 nC. The measured unnormalized beam emittance is 0.33 mm-mrad. These parameters allow for a comprehensive study of focusing of relativistic electron beams with plasma columns, in both the overdense and underdense regime (adiabatic and tapered lenses). A study of adiabatic and/or tapered lenses requires careful control of plasma density and scale lengths of the plasma. We present experimental results on the production of plasmas through resonant two-photon ionization, with parameters relevant to an upcoming plasma lens experiment

  13. Comparison of measured with calculated dose distribution from a 120-MeV electron beam from a laser-plasma accelerator.

    Science.gov (United States)

    Lundh, O; Rechatin, C; Faure, J; Ben-Ismaïl, A; Lim, J; De Wagter, C; De Neve, W; Malka, V

    2012-06-01

    To evaluate the dose distribution of a 120-MeV laser-plasma accelerated electron beam which may be of potential interest for high-energy electron radiation therapy. In the interaction between an intense laser pulse and a helium gas jet, a well collimated electron beam with very high energy is produced. A secondary laser beam is used to optically control and to tune the electron beam energy and charge. The potential use of this beam for radiation treatment is evaluated experimentally by measurements of dose deposition in a polystyrene phantom. The results are compared to Monte Carlo simulations using the geant4 code. It has been shown that the laser-plasma accelerated electron beam can deliver a peak dose of more than 1 Gy at the entrance of the phantom in a single laser shot by direct irradiation, without the use of intermediate magnetic transport or focusing. The dose distribution is peaked on axis, with narrow lateral penumbra. Monte Carlo simulations of electron beam propagation and dose deposition indicate that the propagation of the intense electron beam (with large self-fields) can be described by standard models that exclude collective effects in the response of the material. The measurements show that the high-energy electron beams produced by an optically injected laser-plasma accelerator can deliver high enough dose at penetration depths of interest for electron beam radiotherapy of deep-seated tumors. Many engineering issues must be resolved before laser-accelerated electrons can be used for cancer therapy, but they also represent exciting challenges for future research. © 2012 American Association of Physicists in Medicine.

  14. Low temperature irradiation of iron, zirconium and copper by 10 to 16 MeV protons

    Energy Technology Data Exchange (ETDEWEB)

    Omar, A M

    1978-01-01

    A theoretical analysis of scattering and radiation damage parameters is carried out for 14 MeV neutrons and 10-17 MeV protons on Fe, Ni, Cu, Zr, Nb, and Au. Damage energies are computed for the interactions using both elastic and non-elastic data. The results show that proton encounters deposit a greater damage energy than 14 MeV neutrons. To examine the theoretical results, electrical resistivity measurements are undertaken for Fe, Zr and Cu irradiated at 12 to 17.5K with 10 to 16 MeV protons. Post-irradiation annealing is carried out in situ using a closed-cycle helium-cooled cryostat. Values of the resistivity damage rate are compared with values estimated from the theoretical damage-energy results. Also, the observed stage I recovery is analysed in terms of the corresponding recovery reported for electron and fast-neutron irradiations. The relation between the 16 MeV proton data and published data estimated from a fusion reactor spectrum is discussed. It is also shown that protons create a damage structure similar to a superposition of the damage structures generated by electrons and fast neutrons. The sample state of imperfection is shown to influence the induced damage state in proton irradiation.

  15. The gas bubbles distribution in 600 MeV protons irradiated aluminium

    International Nuclear Information System (INIS)

    Gavillet, D.; Martin, J.L.; Victoria, M.; Green, W.

    1984-01-01

    In order to simulate the damage produced by 14 MeV fusion neutrons, thin foils of high purity Al have been irradiated by a proton beam of 580 MeV (120μA). After irradiation at temperatures higher than 0.5 Tm transmission electron microscope observations of gas bubbles distribution were performed. At 200 0 C a uniform distribution of bubbles has been observed inside the grain. The average distance between bubbles and their density have been determined. The gas pressure inside the bubbles has been estimated [fr

  16. Optimization of the microwave coupler and microwave measurements of the microtron cavity for 20 MeV pre-injector microtron for INDUS-I SRS

    International Nuclear Information System (INIS)

    Wanmode, Y.D.; Shrivastava, Purushottam; Hannurkar, P.R.

    2003-01-01

    A 20 MeV microtron was developed indigenously by CAT for pre-injection of 20 MeV electrons to the 450 MeV/700 MeV Booster Synchrotron for INDUS-I and INDUS-II Synchrotron Radiation Sources. The injector microtron uses a high Q microwave cavity for acceleration of electrons. The microwave power is fed to the microtron cavity through an iris type coupler whose dimensions are optimized for the coupling factor and resonant frequency for the accelerator. The present paper gives the procedure details for coupling factor optimization, tuning of the resonant frequency and results achieved. (author)

  17. Spatial distribution of bremsstrahlung in water and water-iron by 22-MeV electron bombardment measured with activation detectors

    International Nuclear Information System (INIS)

    Nakamura, Takashi; Nishimoto, Takanao; Hirayama, Hideo.

    1977-01-01

    The spatial distributions of bremsstrahlung in water (1 m thick) and water (60 cm thick)-iron (6.3 cm thick) bombarded by 22-MeV electrons were measured by using a new activation method which we developed. These informations are useful for studying shielding, residual activity and radiation damage of accelerator and target materials. From the measured activities, the bremsstrahlung spectra in water were evaluated with the LYRA and the SAND-II unfolding codes. The evaluated spectra were in good agreement with the analytical calculation by the DIBRE code, except for the higher energy ends. The longitudinal and the lateral distributions of bremsstrahlung flux in water were obtained by integrating the evaluated spectra above 8 MeV. The agreement of the experimental and the calculated flux distributions was very good except for a large angle to beam direction. The total photon number crossing a plane normal to the beam axis attenuates exponentially along the axial depth. The iso-flux contour of bremsstrahlung flux was given by interpolating the flux distribution curves. Only the saturated activities of gold detectors were obtained for water-iron in good experimental accuracy. The spatial distribution of gold saturated activities in water-iron clearly shows the attenuating effect due to strong absorption in iron. (auth.)

  18. Food processing using electrons and X-rays

    International Nuclear Information System (INIS)

    Clouston, J.G.

    1985-01-01

    The ionizing radiation which will be used as process energy for the preservation of food, will be limited to high energy electrons (less than 10 MeV), X-rays (less than 5 MeV) and gamma rays emitted by cobalt-60 (1.17;1.33 MeV) and cesium -137 (0.663 MeV). When a foodstuff is irradiated with any of these radiations absorption of the radiant energy will initiate a variety of reactions between its atomic and molecular constituents causing permanent chemical, physical and biological changes. This paper focusses on radiation processing using electron or X-ray generators in the range 2 to 10 MeV

  19. Neutron yield and induced radioactivity: a study of 235-MeV proton and 3-GeV electron accelerators.

    Science.gov (United States)

    Hsu, Yung-Cheng; Lai, Bo-Lun; Sheu, Rong-Jiun

    2016-01-01

    This study evaluated the magnitude of potential neutron yield and induced radioactivity of two new accelerators in Taiwan: a 235-MeV proton cyclotron for radiation therapy and a 3-GeV electron synchrotron serving as the injector for the Taiwan Photon Source. From a nuclear interaction point of view, neutron production from targets bombarded with high-energy particles is intrinsically related to the resulting target activation. Two multi-particle interaction and transport codes, FLUKA and MCNPX, were used in this study. To ensure prediction quality, much effort was devoted to the associated benchmark calculations. Comparisons of the accelerators' results for three target materials (copper, stainless steel and tissue) are presented. Although the proton-induced neutron yields were higher than those induced by electrons, the maximal neutron production rates of both accelerators were comparable according to their respective beam outputs during typical operation. Activation products in the targets of the two accelerators were unexpectedly similar because the primary reaction channels for proton- and electron-induced activation are (p,pn) and (γ,n), respectively. The resulting residual activities and remnant dose rates as a function of time were examined and discussed. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  20. Alanine-EPR dosimetry in 10 MeV electron beam to optimize process parameters for food irradiation

    International Nuclear Information System (INIS)

    Sanyal, B.; Kumar, S.; Kumar, M.; Mittal, K.C.; Sharma, A.

    2011-01-01

    Absorbed dose in a food product is determined and controlled by several components of the LINAC irradiation facility as well as the product. Standardization of the parameters characterizing the facility components, process load and the irradiation conditions collectively termed as 'process parameters' are of paramount importance for successful dose delivery to the food products. In the present study alanine-EPR dosimetry system was employed to optimize the process parameters of 10 MeV electron beam of a LINAC facility for commercial irradiation of food. Three sets of experiments were carried out with different food commodities namely, mango, potato and rawa with the available product conveying system of different irradiation geometry like one sided or both sided mode of irradiation. Three dimensional dose distributions into the process load for low dose requiring food commodities (0.25 to 1 kGy) were measured in each experiment. The actual depth dose profile in food product and useful scan width of the electron beam were found out to be satisfactory for commercial radiation processing of food. Finally a scaled up experiment with commercial food product (packets of Rawa) exhibited adequate dose uniformity ratio of 3 proving the feasibility of the facility for large scale radiation processing of food commodities. (author)

  1. Smith-Purcell radiation from a 50 MeV beam

    Energy Technology Data Exchange (ETDEWEB)

    Brownell, J.H.; Walsh, J. [Dartmouth Coll., Hanover, NH (United States). Dept. of Physics and Astronomy; Kirk, H.G.; Fernow, R.C. [Brookhaven National Lab., Upton, NY (United States). Dept. of Physics; Robertson, S.H. [Univ. of Colorado, Boulder, CO (United States). Dept. of Astrophysics and Geophysics

    1996-10-01

    A 50 MeV electron beam and a 1 mm period, 5{degree} blaze, echelle grating have been used to produce radiation in the mid-infrared spectral region. The emission is highly collimated and forward-directed. The intensity level in the few ps pulse (2 nJ/sr) indicates a degree of coherent enhancement.

  2. Smith-Purcell radiation from a 50 MeV beam

    International Nuclear Information System (INIS)

    Brownell, J.H.; Walsh, J.; Kirk, H.G.; Fernow, R.C.; Robertson, S.H.

    1996-10-01

    A 50 MeV electron beam and a 1 mm period, 5 degree blaze, echelle grating have been used to produce radiation in the mid-infrared spectral region. The emission is highly collimated and forward-directed. The intensity level in the few ps pulse (2 nJ/sr) indicates a degree of coherent enhancement

  3. Electrical behaviour of butyl acrylate/methyl methacrylate copolymer films irradiated with 1.5 MeV electron beam

    Energy Technology Data Exchange (ETDEWEB)

    Radwan, R.M. [Radiation Physics Department, National Center for Radiation Research and Technology (NCRRT), Atomic Energy Authority (AEA), P. O. Box 29, Nasr City, Cairo (Egypt)], E-mail: redaradwan_2000@yahoo.com; Fawzy, Y.H.A. [Radiation Physics Department, National Center for Radiation Research and Technology (NCRRT), Atomic Energy Authority (AEA), P. O. Box 29, Nasr City, Cairo (Egypt); El-Hag Ali, A. [Polymer Chemistry Department, National Center for Radiation Research and Technology (NCRRT), Atomic Energy Authority (AEA), P. O. Box 29, Nasr City, Cairo (Egypt)

    2008-02-15

    Electrical conductivity and dielectric parameters of the (BuA/MMA) copolymer films irradiated with 1.5 MeV electron beam (EB) have been studied. The samples were irradiated with different doses of the electron beam: 5, 10, 50, 125 and 200 kGy. The electrical conductivity of the samples was found to decrease as the irradiation dose increases. The temperature dependence of the direct current (dc) conductivity for unirradiated and irradiated samples has been obtained over a temperature range from 293 to 373 K. The activation energy values were calculated for all samples. Moreover, measurements of the dielectric constant, dielectric loss and alternating current (ac) conductivity were performed at a frequency range from 100 Hz to 5 MHz at room temperature. The results indicated that the EB irradiation has formed some traps in the energy gap, which reduce the movement of the charge carriers. Furthermore, a direct proportional relationship between the activation energy and the irradiation dose was estimated in two regions: below and above the glass transition temperature of the polymer. Dipole relaxation was observed in the samples, and the dose effect was found to shift this relaxation towards higher frequencies.

  4. Study of LiF:Mg,Ti and CaSO4:Dy dosimeters TL response to electron beams of 6 MeV applied to radiotherapy using PMMA and solid water phantoms

    International Nuclear Information System (INIS)

    Bravim, A.; Sakuraba, R.K.; Cruz, J.C.; Campos, L.L.

    2011-01-01

    The performance of CaSO 4 :Dy and LiF:Mg,Ti dosimeters to electron beams applied to radiotherapy was investigated. The TL response of these dosimeters was studied for 6 MeV electron beams using PMMA and Solid Water (SW) phantoms. The dosimeters were previously separated in groups according to their TL individual sensitivities to 60 Co gamma-radiation in air under electronic equilibrium conditions. After that, they were irradiated with 6 MeV electron doses of 0.1, 0.5, 1, 5 and 10 Gy using a linear accelerator Clinac 2100C Varian of Hospital Israelita Albert Einstein – HIAE. The electron beam irradiations were performed using a 10 × 10 cm 2 field size, 100 cm source-phantom surface distance and the dosimeters were positioned at the depth of maximum dose (1.2 cm). The TL readings were carried out between 24 and 32 h after irradiation using a Harshaw 3500 TL reader. The TL dose–response of both type of dosimeters and phantoms presented linear behavior on the electron dose range from 0.1 to 5 Gy CaSO 4 :Dy dosimeter is 21 times more sensitive than LiF:Mg,Ti, dosimeter commonly used in clinical dosimetry. The obtained results indicate that the performance of CaSO 4 :Dy dosimeters is similar to LiF:Mg,Ti dosimeters and this material can be an alternative dosimetric material to be used to clinical electron beams dosimetry.

  5. Absence of large M1 excitations in 208Pb below 8.4 MeV

    International Nuclear Information System (INIS)

    Holt, R.J.; Jackson, H.E.; Laszewski, R.M.; Specht, J.R.

    1979-01-01

    A very high-resolution measurement of the 208 Pb(γ-n 0 ) 207 Pb reaction was performed by use of the unique picopulse and the newly-installed neutron flight paths at the ANL electron linac facility. The 7.99-MeV resonance (E/sub n/ = 610 keV) exhibited a level-level interference pattern with the 7.98-MeV, E1 resonance in 208 Pb. 1 figure

  6. 6 MeV RF Linac for cargo scanning and industrial radiography

    International Nuclear Information System (INIS)

    2017-01-01

    RF Linac-based X-ray sources are very widely used for cargo-scanning and industrial X-ray radiography applications. A 6 MeV on-axis coupled-cavity S-band RF linac has been designed, developed and tested successfully at Electron Beam Centre, Navi Mumbai. This facility falls under the purview of BARC Safety Council, which has conducted safety reviews and awarded regulatory clearances for the operation of the linac system. This paper outlines the salient features of the 6 MeV linac, its safety aspects and test results. A brief history of regulatory aspects is also presented

  7. Film dosimetric investigations on the exposure of the eyes in radiation therapy of the head and the cervical region with fast electrons up to 17 MeV

    International Nuclear Information System (INIS)

    Stecher, M.; Eichler, R.

    1978-01-01

    Dose distributions in irradiating tumors of the head and the cervical region with 17 MeV electrons were determined in a phantom with films. From the isodoses obtained it can be derived how radiation reaches the eyes and how the dose to the eyes is influenced. Guidance is provided for the reduction of the dose to the eye. (author)

  8. Effective dose per unit fluence calculated for adults and a 7 year old girl in broad antero-posterior beams of monoenergetic electrons of 0.1 to 10 MeV

    International Nuclear Information System (INIS)

    Schultz, F.W.; Zoetelief, J.

    1997-01-01

    For broad antero-posterior beams of monoenergetic (0.1-10 MeV) electrons, organ doses per unit fluence were computed through Monte Carlo simulation with reference to male and female adult and a 7 year old girl. Effective doses (E) per unit fluence were calculated for the three phantoms and for an average adult. E increases from about 8 x 10 -14 to about 1.2 x 10 -10 Sv.cm 2 with increasing electron energy. Uncertainties were (often much) better than 6% for the adults, and 18% for the child. E as calculated for the average adult may be used for both males and females as under- or overestimations stay within 25% from E for the average adult. The child's radiation risk is underestimated for electron energies in the range of 0.6 to 3 MeV. This underestimation up to a factor of about 20 is unacceptable for radiological protection purposes. The present results were compared with literature data on operational quantities associated with radiation hazard from weakly penetrating radiation. Neither directional nor personal dose equivalent appears to be a realistic quantity in this case. Both would yield an unnecessarily large safety factor for radiological protection. (author)

  9. A 7MeV S-Band 2998MHz Variable Pulse Length Linear Accelerator System

    CERN Document Server

    Hernandez, Michael; Mishin, Andrey V; Saverskiy, Aleksandr J; Skowbo, Dave; Smith, Richard

    2005-01-01

    American Science and Engineering High Energy Systems Division (AS&E HESD) has designed and commissioned a variable pulse length 7 MeV electron accelerator system. The system is capable of delivering a 7 MeV electron beam with a pulse length of 10 nS FWHM and a peak current of 1 ampere. The system can also produce electron pulses with lengths of 20, 50, 100, 200, 400 nS and 3 uS FWHM with corresponding lower peak currents. The accelerator system consists of a gridded electron gun, focusing coil, an electrostatic deflector system, Helmholtz coils, a standing wave side coupled S-band linac, a 2.6 MW peak power magnetron, an RF circulator, a fast toroid, vacuum system and a PLC/PC control system. The system has been operated at repetition rates up to 250pps. The design, simulations and experimental results from the accelerator system are presented in this paper.

  10. Liquid argon as an electron/photon detector in the energy range of 50 MeV to 2 GeV: a Monte Carlo investigation

    International Nuclear Information System (INIS)

    Goodman, M.S.; Denis, G.; Hall, M.; Karpovsky, A.; Wilson, R.; Gabriel, T.A.; Bishop, B.L.

    1980-12-01

    Monte Carlo techniques which have been used to study the characteristics of a proposed electron/photon detector based on the total absorption of electromagnetic showers in liquid argon have been investigated. The energy range studied was 50 MeV to 2 GeV. Results are presented on the energy and angular resolution predicted for the device, along with the detailed predictions of the transverse and longitudinal shower distributions. Comparisons are made with other photon detectors, and possible applications are discussed

  11. s-wave threshold in electron attachment - Observations and cross sections in CCl4 and SF6 at ultralow electron energies

    Science.gov (United States)

    Chutjian, A.; Alajajian, S. H.

    1985-01-01

    The threshold photoionization method was used to study low-energy electron attachment phenomena in and cross sections of CCl4 and SF6 compounds, which have applications in the design of gaseous dielectrics and diffuse discharge opening switches. Measurements were made at electron energies from below threshold to 140 meV at resolutions of 6 and 8 meV. A narrow resolution-limited structure was observed in electron attachment to CCl4 and SF6 at electron energies below 10 meV, which is attributed to the divergence of the attachment cross section in the limit epsilon, l approaches zero. The results are compared with experimental collisional-ionization results, electron-swarm unfolded cross sections, and earlier threshold photoionization data.

  12. Recovery of Mice Thymus after X-Rays and 15 MeV Electrons. Comparative Study of the Cell Population Using Tritiated Thymidine; Regeneration du Thymus chez la Souris Apres Irradiation par des Rayons X et des Electrons de 15 MeV. Etude Comparee de la Population Cellulaire a l'Aide de Thymidine Tritiee; 0412 043e 0414 ; Restauracion del Timo de los Ratones Despues de Irradiarlo con Rayos X y Electrones de 15 MeV. Estudio Comparativo de la Poblacion Celular Utilizando Timidina Tritiada

    Energy Technology Data Exchange (ETDEWEB)

    Biagini, C.; Paleani Vettori, P. G.; Zito Bignami, R. [Istituto di Radiologia dell' Universita and Comitato Nazionale per l' Energia Nucleare, Rome (Italy)

    1962-02-15

    The mechanism of recovery from acute radiation damage may be studied by using two types of radiations which show small differences in the acute RBE, and large differences of effect in the recovery phase. As observed in previous experiments, this condition is achieved by comparing the effects in mammals of 150 kVpX-rays and those of 15 MeV electrons produced by a betatron. The present paper presents the results of an autoradiographic study on the behaviour of single classes of cells of the mice thymus by use of tritiated thymidine as DNA precursor. Data are related to the modifications in distribution of the size categories of the cell population and to organ weight. After irradiation the large to small cell ratio is increased ; the incorporation of tritiated thymidine is reduced in large and in small lymphocytes. In the acute phase of effect, no significant differences between X-rays and electrons are observed in cell sizes and in labelling of large cells. A relative change appears in labelling of small cells, a fact that may have a relation with the RBE values of fast electrons, in agreement with the organ weight data. In the recovery, less differentiated cells show active proliferation, but the percentage of mature lymphocytes remains small. After exposure to 15 MeV electrons proliferative activity of large cells is greater, according to the time curves of the thymic atrophy. From the above results, regenerative potentiality appears related to the degree of damage on primitive cells; for a given dose, the latter appears larger after X-rays than after electrons. (author) [French] On peut etudier le mecanisme de la guerison de radiolesions aiguees en utilisant deux types de rayonnements, qui ont a peu pres le meme EBR, mais dont les effets sont tres differents pendant la phase de regeneration. Comme les auteurs l'ont observe dans des experiences anterieures, une bonne methode consiste a comparer, chez des mammiferes, les effets des rayons X de 150 kVp avec ceux des

  13. Sustained performance of 8 MeV Microtron

    International Nuclear Information System (INIS)

    Sanjeev, Ganesh

    2012-01-01

    Energetic electrons and intense bremsstrahlung radiation from 8 MeV Microtron are being utilized in variety of collaborative research programs in radiation physics and allied sciences involving premier institutions of the country and sister universities of the region. The first of its kind electron accelerator in the country, set up at Mangalore University in collaboration with RRCAT Indore and BARC Mumbai, has been facilitating researchers since its inception with its inherent simplicity, ease of construction, low cost and excellent beam quality. A bird's eye view on the reliable aspects of the machine, efforts behind the continuous operation of the accelerator and important applications of the accelerator in physical and biological sciences are presented in this paper.

  14. Mega-electron-volt ultrafast electron diffraction at SLAC National Accelerator Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Weathersby, S. P.; Brown, G.; Chase, T. F.; Coffee, R.; Corbett, J.; Eichner, J. P.; Frisch, J. C.; Fry, A. R.; Gühr, M.; Hartmann, N.; Hast, C.; Hettel, R.; Jobe, R. K.; Jongewaard, E. N.; Lewandowski, J. R.; Li, R. K., E-mail: lrk@slac.stanford.edu; Lindenberg, A. M.; Makasyuk, I.; May, J. E.; McCormick, D. [SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, California 94025 (United States); and others

    2015-07-15

    Ultrafast electron probes are powerful tools, complementary to x-ray free-electron lasers, used to study structural dynamics in material, chemical, and biological sciences. High brightness, relativistic electron beams with femtosecond pulse duration can resolve details of the dynamic processes on atomic time and length scales. SLAC National Accelerator Laboratory recently launched the Ultrafast Electron Diffraction (UED) and microscopy Initiative aiming at developing the next generation ultrafast electron scattering instruments. As the first stage of the Initiative, a mega-electron-volt (MeV) UED system has been constructed and commissioned to serve ultrafast science experiments and instrumentation development. The system operates at 120-Hz repetition rate with outstanding performance. In this paper, we report on the SLAC MeV UED system and its performance, including the reciprocal space resolution, temporal resolution, and machine stability.

  15. Modification of the microstructure and electronic properties of rutile TiO_2 thin films with 79 MeV Br ion irradiation

    International Nuclear Information System (INIS)

    Rath, Haripriya; Dash, P.; Singh, U.P.; Avasthi, D.K.; Kanjilal, D.; Mishra, N.C.

    2015-01-01

    Modifications induced by 79 MeV Br ions in rutile titanium dioxide thin films, synthesized by dc magnetron sputtering are presented. Irradiations did not induce any new XRD peak corresponding to any other phase. The area and the width of the XRD peaks were considerably affected by irradiation, and peaks shifted to lower angles. But the samples retained their crystallinity at the highest fluence (1 × 10"1"3 ions cm"−"2) of irradiation even though the electronic energy loss of 79 MeV Br ions far exceeds the reported threshold value for amorphization of rutile TiO_2. Fitting of the fluence dependence of the XRD peak area to Poisson equation yielded the radius of ion tracks as 2.4 nm. Ion track radius obtained from the simulation based on the thermal spike model matches closely with that obtained from the fluence dependence of the area under XRD peaks. Williamson–Hall analysis of the XRD spectra indicated broadening and shifting of the peaks are a consequence of irradiation induced defect accumulation leading to microstrains, as was also indicated by Raman and UV–Visible absorption study.

  16. Unified 1.9...4.0 MeV linear accelerators with interchangeable accelerating structures for customs inspection

    International Nuclear Information System (INIS)

    Budtov, A.A.; Klinov, A.P.; Krestianinov, A.S.

    2004-01-01

    A series of compact linear electron accelerators for 1.9, 2.5 and 4.0 MeV equipped with a local radiation shielding has been designed and constructed in the NPK LUTS, the D.V.Efremov Institute (NIIEFA). The accelerators are intended for mobile facilities used for customs inspection of large-scale containers. Results of optimizing calculations of irradiator parameters and electron dynamics, verified under accelerators testing, are presented in the report. The main design approaches allowing the construction of unified accelerators with interchangeable accelerating structures for energies in the range of 1.9...4.0 MeV are also given

  17. Observation of optical Smith-Purcell radiation at an electron beam energy of 855 MeV

    International Nuclear Information System (INIS)

    Kube, G.; Backe, H.; Euteneuer, H.; Grendel, A.; Hagenbuck, F.; Hartmann, H.; Kaiser, K.H.; Lauth, W.; Schoepe, H.; Wagner, G.; Walcher, Th.; Kretzschmar, M.

    2002-01-01

    Smith-Purcell radiation, generated when a beam of charged particles passes close to the surface of a diffraction grating, has been studied in the visible spectral range at wavelengths of 360 and 546 nm with the low emittance 855 MeV electron beam of the Mainz Microtron MAMI. The beam focused to a spot size of 4 μm (full width at half maximum) passed over optical diffraction gratings of echelle profiles with blaze angles of 0.8 deg., 17.27 deg., and 41.12 deg. and grating periods of 0.833 and 9.09 μm. Taking advantage of the specific emission characteristics of Smith-Purcell radiation a clear separation from background components, such as diffracted synchrotron radiation from upstream beam optical elements and transition radiation, was possible. The intensity scales with a modified Bessel function of the first kind as a function of the distance between electron beam and grating surface. Experimental radiation factors have been determined and compared with calculations on the basis of Van den Berg's theory [P.M. Van den Berg, J. Opt. Soc. Am. 63, 689 (1973)]. Fair agreement has been found for gratings with large blaze angles while the measurement with the shallow grating (blaze angle 0.8 deg.) is at variance with this theory. Finally, the optimal operational parameters of a Smith-Purcell radiation source in view of already existing powerful undulator sources are discussed

  18. MeV ion beam interaction with polymer films containing cross-linking agents

    International Nuclear Information System (INIS)

    Evelyn, A. L.

    1999-01-01

    Polymer films containing cross linking enhancers were irradiated with MeV alpha particles to determine the effects of MeV ion beam interaction on these materials. The contributed effects from the electronic and nuclear stopping powers were separated by irradiating stacked thin films of polyvinyl chloride (PVC), polystyrene (PS) and polyethersulfone (PES). This layered system allowed most of the effects of the electronic energy deposited to be experienced by the first layers and the last layers to receive most of the effects of the nuclear stopping power. RGA, Raman microprobe analysis, RBS and FTIR measured changes in the chemical structures of the irradiated films. The characterization resolved the effects of the stopping powers on the PVC, PS and PES and the results were compared with those from previously studied polymers that did not contain any cross linking agents

  19. Optical and electronic properties of sub-surface conducting layers in diamond created by MeV B-implantation at elevated temperatures

    Energy Technology Data Exchange (ETDEWEB)

    Willems van Beveren, L. H., E-mail: laurensw@unimelb.edu.au; Bowers, H.; Ganesan, K.; Johnson, B. C.; McCallum, J. C.; Prawer, S. [School of Physics, University of Melbourne, Parkville, Victoria 3010 (Australia); Liu, R. [SIMS Facility, Office of the Deputy-Vice Chancellor (Research and Development) Western Sydney University, Locked Bag 1797, Penrith, New South Wales 2751 (Australia)

    2016-06-14

    Boron implantation with in-situ dynamic annealing is used to produce highly conductive sub-surface layers in type IIa (100) diamond plates for the search of a superconducting phase transition. Here, we demonstrate that high-fluence MeV ion-implantation, at elevated temperatures avoids graphitization and can be used to achieve doping densities of 6 at. %. In order to quantify the diamond crystal damage associated with implantation Raman spectroscopy was performed, demonstrating high temperature annealing recovers the lattice. Additionally, low-temperature electronic transport measurements show evidence of charge carrier densities close to the metal-insulator-transition. After electronic characterization, secondary ion mass spectrometry was performed to map out the ion profile of the implanted plates. The analysis shows close agreement with the simulated ion-profile assuming scaling factors that take into account an average change in diamond density due to device fabrication. Finally, the data show that boron diffusion is negligible during the high temperature annealing process.

  20. Electron beam irradiation effect on GaN HEMT

    International Nuclear Information System (INIS)

    Lou Yinhong; Guo Hongxia; Zhang Keying; Wang Yuanming; Zhang Fengqi

    2011-01-01

    In this work, GaN HEMTs (High Electron Mobility Transistor) were irradiated by 0.8 and 1.2 MeV electron beams, and the irradiation effects were investigated. The results show that the device damage caused by 0.8 MeV electrons is more serious than that by 1.2 MeV electrons. Saturation drain current increase and threshold voltage negative shift are due to trapped positive charge from ionization in the AlGaN layer and N, Ga vacancy from non-ionizing energy loss in the GaN layer. Electron traps and trapped positive charges from non-ionizing in the AlGaN layer act as trap-assisted-tunneling centers that increase the gate leakage current.(authors)

  1. Evidence for two narrow pp resonances at 2020 MeV and 2200 MeV

    CERN Document Server

    Benkheiri, P; Bouquet, B; Briandet, P; D'Almagne, B; Dang-Vu, C; De Rosny, G; Eisenstein, B I; Ferrer, A; Fleury, P; Grossetête, B; Irwin, G; Jacholkowski, A; Lahellec, A; Nguyen, H; Petroff, P; Richard, F; Rivet, P; Roudeau, P; Rougé, A; Rumpf, M; Six, J; Thénard, J M; Treille, D; Volte, A; Yaffe, D; Yiou, T P; Yoshida, H

    1977-01-01

    From the study of the reaction pi /sup -/p to p/sub F/pp pi /sup -/ using a fast proton (p/sub F/) trigger device in the CERN Omega spectrometer, the authors find evidence for two narrow pp states produced mainly in association with a Delta degrees (1232) and a N degrees (1520). The statistical significance of each peak is greater than 6 standard deviations. Masses and natural widths of these resonances are respectively M/sub 1/=2020+or-3 MeV, Gamma /sub 1 /=24+or-12 MeV and M/sub 2/=2204+or-5 MeV, Gamma /sub 2/=16/sub -16 //sup +20/ MeV. The data are consistent with a small production of the narrow approximately 1935 MeV resonance already reported. Production cross sections for these new pp resonances are given. (8 refs).

  2. Transverse self-fields within an electron bunch moving in an arc of a circle

    International Nuclear Information System (INIS)

    Geloni, G.; Botman, J.; Luiten, J.; Wiel, M. van der; Yurkov, M.V.

    2002-04-01

    As a consequence of motions driven by external forces, self-fields (which are different from the static case) originate within an electron bunch. In the case of magnetic external forces acting on an ultrarelativistic beam, the longitudinal self-interactions are responsible for CSR (coherent synchrotron radiation)-related phenomena, which have been studied extensively. On the other hand, transverse self-interactions are present too. At the time being, existing theoretical analysis of transverse self-forces deal with the case of a bunch moving along a circular orbit only, without considering the situation of a bending magnet with a finite length. In this paper we propose an electrodynamical analysis of transverse self-fields which originate, at the position of a test particle, from an ultrarelativistic electron bunch moving in an arc of a circle. The problem will be first addressed within a two-particle system. We then extend our consideration to a line bunch with a stepped density distribution, a situation which can be easily generalized to the case of an arbitrary density distribution. Our approach turns out to be also useful in order to get a better insight in the physics involved in the case of simple circular motion and in order to address the well known issue of the partial compensation of transverse self-force. (orig.)

  3. A sub-50meV spectrometer and energy filter for use in combination with 200kV monochromated (S)TEMs.

    Science.gov (United States)

    Brink, H A; Barfels, M M G; Burgner, R P; Edwards, B N

    2003-09-01

    A high-energy resolution post-column spectrometer for the purpose of electron energy loss spectroscopy (EELS) and energy-filtered TEM in combination with a monochromated (S)TEM is presented. The prism aberrations were corrected up to fourth order using multipole elements improving the electron optical energy resolution and increasing the acceptance of the spectrometer for a combination of object area and collection angles. Electronics supplying the prism, drift tube, high-tension reference and critical lenses have been newly designed such that, in combination with the new electron optics, a sub-50 meV energy resolution has been realized, a 10-fold improvement over past post-column spectrometer designs. The first system has been installed on a 200 kV monochromated TEM at the Delft University of Technology. Total system energy resolution of sub-100 meV has been demonstrated. For a 1s exposure the resolution degraded to 110 meV as a result of noise. No further degradation in energy resolution was measured for exposures up to 1 min at 120 kV. Spectral resolution measurements, performed on the pi* peak of the BN K-edge, demonstrated a 350 meV (FWHM) peak width at 200 kV. This measure is predominantly determined by the natural line width of the BN K-edge.

  4. Electron Flux Models for Different Energies at Geostationary Orbit

    Science.gov (United States)

    Boynton, R. J.; Balikhin, M. A.; Sibeck, D. G.; Walker, S. N.; Billings, S. A.; Ganushkina, N.

    2016-01-01

    Forecast models were derived for energetic electrons at all energy ranges sampled by the third-generation Geostationary Operational Environmental Satellites (GOES). These models were based on Multi-Input Single-Output Nonlinear Autoregressive Moving Average with Exogenous inputs methodologies. The model inputs include the solar wind velocity, density and pressure, the fraction of time that the interplanetary magnetic field (IMF) was southward, the IMF contribution of a solar wind-magnetosphere coupling function proposed by Boynton et al. (2011b), and the Dst index. As such, this study has deduced five new 1 h resolution models for the low-energy electrons measured by GOES (30-50 keV, 50-100 keV, 100-200 keV, 200-350 keV, and 350-600 keV) and extended the existing >800 keV and >2 MeV Geostationary Earth Orbit electron fluxes models to forecast at a 1 h resolution. All of these models were shown to provide accurate forecasts, with prediction efficiencies ranging between 66.9% and 82.3%.

  5. Detection of two electrons in low-lying continuum states of a single projectile ion resulting from the collision of a 10.7-MeV Ag4+ ion with an Ar gas atom

    International Nuclear Information System (INIS)

    Richards, J.D.; Breinig, M.; Gaither, C.C.; Berryman, J.W.; Hasson, B.F.

    1993-01-01

    Two electrons, excited just above the double-ionization threshold of an Ag q+ (q=5,6) core in a single collision of a 0.1-MeV/u Ag 4+ projectile ion with an Ar atom, are detected. The electron detector consists of electrically isolated anode segments located behind a microchannel-plate electron multiplier. A large electrostatic 30 degree parallel-plate analyzer is used to deflect the two free electrons, which move with approximately the projectile velocity, into the detector. The cross sections for producing final states consisting of a positively charged ionic core and two electrons just above the threshold for double ionization in ion-atom collisions have been measured. The cross sections for producing states with one electron moving with a kinetic energy less than 0.13 eV in the projectile frame and the other moving with somewhat higher kinetic energy are presented

  6. Molecular effects in carbon K-shell Auger-electron production by 0.6-2.0 MeV protons and extraction of an atomic cross section

    International Nuclear Information System (INIS)

    McDaniel, F.D.; Lapicki, G.

    1987-01-01

    Carbon K-shell Auger-electron production cross sections are reported for 0.6-2.0 MeV protons incident on CH 4 (methane), C 2 H 2 (acetylene), C 2 H 4 (ethylene), C 2 H 6 (ethane), n-C 4 H 10 (normal butane), i-C 4 H 10 (isobutane), C 6 H 6 (benzene), CO (carbon monoxide), and CO 2 (carbon dioxide). A constant-energy mode 45 0 parallel-plate electrostatic analyzer was used for detection of Auger electrons. The carbon KLL Auger-electron cross sections for all molecules were found to be lower than that found for CH 4 by 9-23%. All carbon KLL Auger-electron data could be brought into agreement when corrected for the chemical shift of the carbon K-shell binding energy in molecules and for intramolecular scattering. KLL Auger-electron production cross sections are compared to first Born and ECPSSR theories and show good agreement with both after the chemical shift of the carbon K-shell binding energy in molecules and the effects of intramolecular scattering are considered. (orig.)

  7. Positron probing of open vacancy volume of phosphorus-vacancy complexes in float-zone n-type silicon irradiated by 0.9-MeV electrons and by 15-MeV protons

    Energy Technology Data Exchange (ETDEWEB)

    Arutyunov, Nikolay [Department of Physics, Martin Luther University Halle (Germany); Ioffe Physico-Technical Institute, St. Petersburg (Russian Federation); Institute of Ion-Plasma and Laser Technologies (Institute of Electronics), Tashkent (Uzbekistan); Emtsev, Vadim; Oganesyan, Gagik [Ioffe Physico-Technical Institute, St. Petersburg (Russian Federation); Elsayed, Mohamed [Department of Physics, Martin Luther University Halle (Germany); Faculty of Science, Department of Physics, Minia University (Egypt); Krause-Rehberg, Reinhard [Department of Physics, Martin Luther University Halle (Germany); Abrosimov, Nikolay [Leibniz Institute for Crystal Growth, Berlin (Germany); Kozlovski, Vitalii [St. Petersburg State Polytechnical University (Russian Federation)

    2017-07-15

    For the first time the samples, cut from the same wafer of crystals of float-zone silicon, n-FZ-Si(P) and n-FZ-Si(Bi), were subjected to irradiation with 0.9-MeV electrons and 15-MeV protons at RT for studying them by low-temperature positron annihilation lifetime spectroscopy. Measurements of Hall effect have been used for the materials characterization. The discussion is focused on the open vacancy volume (V{sub op}) of the thermally stable group-V-impurity-vacancy complexes comprising the phosphorus atoms; the bismuth-related vacancy complexes are briefly considered. The data of positron probing of PV pairs (E-centers), divacancies, and the thermally stable defects in the irradiated n-FZ-Si(P) materials are compared. Beyond a reliable detecting of the defect-related positron annihilation lifetime in the course of isochronal annealing at ∝ 500 C, the recovery of concentration of phosphorus-related shallow donor states continues up to ∝650-700 C. The open vacancy volumes V{sub op} to be characterized by long positron lifetimes Δτ{sub 2} ∝271-289 ps in (gr.-V-atom)-V{sub op} complexes are compared with theoretical data available for the vacancies, τ(V{sub 1}), and divacancies, τ(V{sub 2}). The extended semi-vacancies, 2V{sub s-ext}, and relaxed vacancies, 2V{sub inw}, are proposed as the open volume V{sub op} in (gr.-V-atom)-V{sub op} complexes. It is argued that at high annealing temperature the defect P{sub s}-V{sub op}-P{sub s} is decomposed. (copyright 2017 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  8. Yields of Radionuclides Created by Photonuclear Reactions on Be, C, Na, Cl, and Ge, Using Bremsstrahlung of 150-MeV Electrons

    International Nuclear Information System (INIS)

    Dickens, J.K.

    2001-01-01

    The bremsstrahlung created by 150-MeV electrons impinging on a tantalum radiator was used to study photonuclear reactions on samples containing Be, C, Na, Cl and Ge. For Ge fifteen radioisotopes, ranging in half life between 2.6 min and 271 days, and in mass between 65 and 75, were obtained in sufficient amount to determine their yields quantitatively using known decay gamma-rays. Special equipment is described which was developed to create the bremsstrahlung using a beam-sharing mode, while minimizing the neutron flux on the sample. Relative production rates were determined. These were analyzed to provide absolute average cross sections for production of three reactions

  9. Anisotropic deformation of metallo-dielectric core-shell colloids under MeV ion irradiation

    International Nuclear Information System (INIS)

    Penninkhof, J.J.; Dillen, T. van; Roorda, S.; Graf, C.; Blaaderen, A. van; Vredenberg, A.M.; Polman, A.

    2006-01-01

    We have studied the deformation of metallo-dielectric core-shell colloids under 4 MeV Xe, 6 and 16 MeV Au, 30 MeV Si and 30 MeV Cu ion irradiation. Colloids of silica surrounded by a gold shell, with a typical diameter of 400 nm, show anisotropic plastic deformation under MeV ion irradiation, with the metal flowing conform the anisotropically deforming silica core. The 20 nm thick metal shell imposes a mechanical constraint on the deforming silica core, reducing the net deformation strain rate compared to that of pure silica. In colloids consisting of a Au core and a silica shell, the silica expands perpendicular to the ion beam, while the metal core shows a large elongation along the ion beam direction, provided the silica shell is thick enough (>40 nm). A minimum electronic energy loss of 3.3 keV/nm is required for shape transformation of the metal core. Silver cores embedded in a silica shell show no elongation, but rather disintegrate. Also in planar SiO 2 films, Au and Ag colloids show entirely different behavior under MeV irradiation. We conclude that the deformation model of core-shell colloids must include ion-induced particle disintegration in combination with thermodynamical effects, possibly in combination with mechanical effects driven by stresses around the ion tracks

  10. Anisotropic deformation of metallo-dielectric core shell colloids under MeV ion irradiation

    Science.gov (United States)

    Penninkhof, J. J.; van Dillen, T.; Roorda, S.; Graf, C.; van Blaaderen, A.; Vredenberg, A. M.; Polman, A.

    2006-01-01

    We have studied the deformation of metallo-dielectric core-shell colloids under 4 MeV Xe, 6 and 16 MeV Au, 30 MeV Si and 30 MeV Cu ion irradiation. Colloids of silica surrounded by a gold shell, with a typical diameter of 400 nm, show anisotropic plastic deformation under MeV ion irradiation, with the metal flowing conform the anisotropically deforming silica core. The 20 nm thick metal shell imposes a mechanical constraint on the deforming silica core, reducing the net deformation strain rate compared to that of pure silica. In colloids consisting of a Au core and a silica shell, the silica expands perpendicular to the ion beam, while the metal core shows a large elongation along the ion beam direction, provided the silica shell is thick enough (>40 nm). A minimum electronic energy loss of 3.3 keV/nm is required for shape transformation of the metal core. Silver cores embedded in a silica shell show no elongation, but rather disintegrate. Also in planar SiO2 films, Au and Ag colloids show entirely different behavior under MeV irradiation. We conclude that the deformation model of core-shell colloids must include ion-induced particle disintegration in combination with thermodynamical effects, possibly in combination with mechanical effects driven by stresses around the ion tracks.

  11. Clinical meaning of radiodermatitis considering the surface dose of supervoltage electron beam

    Energy Technology Data Exchange (ETDEWEB)

    Hiraki, T [Kanazawa Univ. (Japan). School of Paramedicine; Rikimaru, S; Kakishita, M; Kuranishi, M

    1975-12-01

    In our experience using supervoltage betatron electron beam, the skin surface dose of the electron decreased when the energy became either greater or less than 18 MeV. When we considered 18 MeV to be a 100% dose, the dose with 4 MeV, which was the least amount, corresponded to 81% of the dose. The skin surface dose of 10 MeV betatron electrons or more became greater than the 90% standard tumor dose. An external irradiation of more than 10 MeV should not be applied to neoplasms of which the curative ratio is less than 1.0. Therefore another methods such as intraoperative irradiation, should be used. The surface skin dose about 4 to 6 MeV betatron postoperative irradiation, particularly after resection of breast cancer, was less than the skin dose with 10 MeV. Close care should be taken to prevent hot lesions which are caused by duplication of irradiation fields. It should be kept in mind that the late effects of hot lesions caused by electron beam irradiation with an energy of 10 MeV or more are serious.

  12. RBE of 0.85 MeV neutrons in Guinea pigs with a cerebral form of radiation sickness

    International Nuclear Information System (INIS)

    Shaporov, V.N.; Sokolova, T.I.; Nasonova, T.A.; Aleshin, S.I.

    1989-01-01

    The RBE coefficient of neutrons (0.85 MeV) was 1.87 in comparison with that of electron radiation (8 MeV) as determined by the death rate of guinea pigs with the cerebral form of radiation sickness. LD 50/1.5 amounted to 43.2 and 80.7 Gy. The dynamics of clinical symptoms at the height of the disease is discussed

  13. Study of the thermal oxidation of titanium and zirconium under argon ion irradiation in the low MeV range (E = 15 MeV)

    International Nuclear Information System (INIS)

    Do, N.-L.

    2012-01-01

    We have shown that argon ion irradiation between 1 and 15 MeV produces damage on both titanium and zirconium surfaces, taking the form of accelerated oxidation and/or craterization effects, varying as a function of the projectile energy and the annealing atmosphere (temperature and pressure) simulating the environmental conditions of the fuel/cladding interface of PWR fuel rods. Using AFM, we have shown that the titanium and zirconium surface is attacked under light argon ion bombardment at high temperature (up to 500 C) in weakly oxidizing medium (under rarefied dry air pressure ranging from 5,7 10 -5 Pa to 5 10 -3 Pa) for a fixed fluence of about 5 10 14 ions.cm -2 . We observed the formation of nano-metric craters over the whole titanium surface irradiated between 2 and 9 MeV and the whole zirconium surface irradiated at 4 MeV, the characteristics of which vary depending on the temperature and the pressure. In the case of the Ar/Ti couple, the superficial damage efficiency increases when the projectile energy decreases from 9 to 2 MeV. Moreover, whereas the titanium surface seems to be transparent under the 15-MeV ion beam, the zirconium surface exhibits numerous micrometric craters surrounded by a wide halo. The crater characteristics (size and superficial density) differ significantly from that observed both in the low energy range (keV) where the energy losses are controlled by ballistic collisions (Sn) and in the high energy range (MeV - GeV) where the energy losses are controlled by electronic excitations (Se), which was not completely unexpected in this intermediate energy range for which combined Sn - Se stopping power effects are possibly foreseen. Using XPS associated to ionic sputtering, we have shown that there is an irradiation effect on thermal oxidation of titanium, enhanced under the argon ion beam between 2 and 9 MeV, and that there is also an energy effect on the oxide thickness and stoichiometry. The study conducted using Spectroscopic

  14. Measurement of 1.7–74 MeV polarised γ rays with the HARPO TPC

    Energy Technology Data Exchange (ETDEWEB)

    Geerebaert, Y., E-mail: yannick.geerebaert@polytechnique.fr [LLR, École Polytechnique, CNRS/IN2P3, Palaiseau (France); Gros, Ph., E-mail: philippe.gros@llr.in2p3.fr [LLR, École Polytechnique, CNRS/IN2P3, Palaiseau (France); Amano, S. [LASTI, University of Hyôgo (Japan); Attié, D. [CEA, Irfu, CEA-Saclay (France); Bernard, D.; Bruel, P. [LLR, École Polytechnique, CNRS/IN2P3, Palaiseau (France); Calvet, D.; Colas, P. [CEA, Irfu, CEA-Saclay (France); Daté, S. [JASRI/SPring8 (Japan); Delbart, A. [CEA, Irfu, CEA-Saclay (France); Frotin, M.; Giebels, B. [LLR, École Polytechnique, CNRS/IN2P3, Palaiseau (France); Götz, D. [AIM, CEA/DSM-CNRS – Université Paris Diderot (France); IRFU/Service d' Astrophysique, CEA-Saclay (France); Hashimoto, S. [LASTI, University of Hyôgo (Japan); Horan, D. [LLR, École Polytechnique, CNRS/IN2P3, Palaiseau (France); Kotaka, T. [LASTI, University of Hyôgo (Japan); Louzir, M. [LLR, École Polytechnique, CNRS/IN2P3, Palaiseau (France); Minamiyama, Y.; Miyamoto, S. [LASTI, University of Hyôgo (Japan); Ohkuma, H. [JASRI/SPring8 (Japan); and others

    2017-02-11

    Current γ-ray telescopes based on photon conversions to electron-positron pairs, such as Fermi, use tungsten converters. They suffer of limited angular resolution at low energies, and their sensitivity drops below 1 GeV. The low multiple scattering in a gaseous detector gives access to higher angular resolution in the MeV–GeV range, and to the linear polarisation of the photons through the azimuthal angle of the electron-positron pair. HARPO is an R&D programme to characterise the operation of a TPC (Time Projection Chamber) as a high angular-resolution and sensitivity telescope and polarimeter for γ rays from cosmic sources. It represents a first step towards a future space instrument. A 30 cm cubic TPC demonstrator was built, and filled with 2 bar argon-based gas. It was put in a polarised γ-ray beam at the NewSUBARU accelerator in Japan in November 2014. Data were taken at different photon energies from 1.7 MeV to 74 MeV, and with different polarisation configurations. The electronics setup is described, with an emphasis on the trigger system. The event reconstruction algorithm is quickly described, and preliminary measurements of the polarisation of 11 MeV photons are shown.

  15. Dosimetric evaluation of lead and tungsten eye shields in electron beam treatment

    International Nuclear Information System (INIS)

    Shiu, Almon S.; Tung, Samuel S.; Gastorf, Robert J.; Hogstrom, Kenneth R.; Morrison, William H.; Peters, Lester J.

    1996-01-01

    Purpose: The purpose of this study is to report that commercially available eye shields (designed for orthovoltage x-rays) are inadequate to protect the ocular structures from penetrating electrons for electron beam energies equal to or greater than 6 MeV. Therefore, a prototype medium size tungsten eye shield was designed and fabricated. The advantages of the tungsten eye shield over lead are discussed. Methods and Materials: Electron beams (6-9 MeV) are often used to irradiate eyelid tumors to curative doses. Eye shields can be placed under the eyelids to protect the globe. Film and thermoluminescent dosimeters (TLDs) were used within a specially constructed polystyrene eye phantom to determine the effectiveness of various commercially available internal eye shields (designed for orthovoltage x-rays). The same procedures were used to evaluate a prototype medium size tungsten eye shield (2.8 mm thick), which was designed and fabricated for protection of the globe from penetrating electrons for electron beam energy equal to 9 MeV. A mini-TLD was used to measure the dose enhancement due to electrons backscattered off the tungsten eye shield, both with or without a dental acrylic coating that is required to reduce discomfort, permit sterilization of the shield, and reduce the dose contribution from backscattered electrons. Results: Transmission of a 6 MeV electron beam through a 1.7 mm thick lead eye shield was found to be 50% on the surface (cornea) of the phantom and 27% at a depth of 6 mm (lens). The thickness of lead required to stop 6-9 MeV electron beams is impractical. In place of lead, a prototype medium size tungsten eye shield was made. For 6 to 9 MeV electrons, the doses measured on the surface (cornea) and at 6 mm (lens) and 21 mm (retina) depths were all less than 5% of the maximum dose of the open field (4 x 4 cm). Electrons backscattered off a tungsten eye shield without acrylic coating increased the lid dose from 85 to 123% at 6 MeV and 87 to 119% at

  16. s-wave threshold in electron attachment - Results in 2-C4F6 and CFCl3 at ultra-low electron energies

    Science.gov (United States)

    Chutjian, A.; Alajajian, S. H.; Ajello, J. M.; Orient, O. J.

    1984-01-01

    Electron attachment lineshapes and cross sections are reported for the processes 2-C4F6(-)/2-C4F6 and Cl(-)/CFCl3 at electron energies of 0-120 and 0-140 meV, and at resolutions of 6 and 7 meV (FWHM), respectively. As in previous measurements in CCl4 and SF6, the results show resolution-limited narrow structure in the cross section at electron energies below 15 meV. This structure arises from the divergence of the s-wave cross section in the limit of zero electron energy. Comparisons are given with swarm-measured results, and with collisional ionization (high-Rydberg attachment) data in this energy range.

  17. Calibration of a large multi-element neutron counter in the energy range 85-430 MeV

    CERN Document Server

    Strong, J A; Esterling, R J; Garvey, J; Green, M G; Harnew, N; Jane, M R; Jobes, M; Mawson, J; McMahon, T; Robertson, A W; Thomas, D H

    1978-01-01

    Describes the calibration of a large 60 element neutron counter with a threshold of 2.7 MeV equivalent electron energy. The performance of the counter has been measured in the neutron kinetic energy range 8.5-430 MeV using a neutron beam at the CERN Synchrocyclotron. The results obtained for the efficiency as a function of energy are in reasonable agreement with a Monte Carlo calculation. (7 refs).

  18. The 16 MeV - microtron at the Institute for Physics and Technology of Radiation Devices and its application

    International Nuclear Information System (INIS)

    Catana, D.; Panaitescu, I.; Axinescu, S.; Minea, R.

    1992-01-01

    The 17-orbit microtron at the Institute for Physics and Technology of Radiation Devices, Bucharest is described. The energy of electrons is 11 MeV in the first accelerating mode and 16 MeV in the second accelerating mode with a pulse beam power of about 400 Kw and a duty ratio of 10 -3 . (Author)

  19. Impact of electron irradiation on particle track etching response in ...

    Indian Academy of Sciences (India)

    In the present work, attempts have been made to investigate the modification in particle track etching response of polyallyl diglycol carbonate (PADC) due to impact of 2 MeV electrons. PADC samples pre-irradiated to 1, 10, 20, 40, 60, 80 and 100 Mrad doses of 2 MeV electrons were further exposed to 140 MeV 28Si beam ...

  20. Variational nonadiabatic dynamics in the moving crude adiabatic representation: Further merging of nuclear dynamics and electronic structure

    Science.gov (United States)

    Joubert-Doriol, Loïc; Izmaylov, Artur F.

    2018-03-01

    A new methodology of simulating nonadiabatic dynamics using frozen-width Gaussian wavepackets within the moving crude adiabatic representation with the on-the-fly evaluation of electronic structure is presented. The main feature of the new approach is the elimination of any global or local model representation of electronic potential energy surfaces; instead, the electron-nuclear interaction is treated explicitly using the Gaussian integration. As a result, the new scheme does not introduce any uncontrolled approximations. The employed variational principle ensures the energy conservation and leaves the number of electronic and nuclear basis functions as the only parameter determining the accuracy. To assess performance of the approach, a model with two electronic and two nuclear spacial degrees of freedom containing conical intersections between potential energy surfaces has been considered. Dynamical features associated with nonadiabatic transitions and nontrivial geometric (or Berry) phases were successfully reproduced within a limited basis expansion.

  1. Responses of conventional and extended-range neutron detectors in mixed radiation fields around a 150-MeV electron LINAC

    International Nuclear Information System (INIS)

    Lin, Yu-Chi; Sheu, Rong-Jiun; Chen, Ang-Yu

    2015-01-01

    This study analyzed the responses of two types of neutron detector in mixed gamma-ray and neutron radiation fields around a 150-MeV electron linear accelerator (LINAC). The detectors were self-assembled, high efficiency, and designed in two configurations: (1) a conventional moderated-type neutron detector based on a large cylindrical He-3 proportional counter; and (2) an extended-range version with an embedded layer of lead in the moderator to increase the detector’s sensitivity to high-energy neutrons. Two sets of the detectors were used to measure neutrons at the downstream and lateral locations simultaneously, where the radiation fields differed considerably in intensities and spectra of gamma rays and neutrons. Analyzing the detector responses through a comparison between calculations and measurements indicated that not only neutrons but also high-energy gamma rays (>5 MeV) triggered the detectors because of photoneutrons produced in the detector materials. In the lateral direction, the contribution of photoneutrons to both detectors was negligible. Downstream of the LINAC, where high-energy photons were abundant, photoneutrons contributed approximately 6% of the response of the conventional neutron detector; however, almost 50% of the registered counts of the extended-range neutron detector were from photoneutrons because of the presence of the detector rather than the effect of the neutron field. Dose readings delivered by extended-range neutron detectors should be interpreted cautiously when used in radiation fields containing a mixture of neutrons and high-energy gamma rays

  2. Sustained >100 MeV Gamma-Ray Emission: A Monitor for >300 MeV SEP Protons at the Sun

    Science.gov (United States)

    Share, G. H.; Murphy, R. J.

    2017-12-01

    Solar γ radiation is the product of proton and ion interactions in the solar atmosphere. The spectrum and temporal characteristics of the emission provides fundamental information on the ions at the Sun. Until the launch of the Fermi satellite, with its Large Area Telescope (LAT) sensitive to radiation above 100 MeV, most of the γ-ray observations were made in the nuclear energy range with radiation arising from interaction of one to tens of MeV ions produced in solar flares. Since 2008 the LAT has detected 30 high-energy γ-ray events with temporal and spectral characteristics that are distinct from the associated solar flare. We call this radiation Sustained Gamma-Ray Emission (SGRE) and briefly summarize its characteristics reported in a recent paper. The γ-ray spectra are consistent with pion decay radiation produced by protons above 300 MeV. The onset of the radiation most often occurs after the impulsive flare and the emission can last several hours. We find that the number of protons responsible for the SGRE is typically more than 10 times the number of flare-accelerated protons. These characteristics require that there be an additional source of energy to accelerate the protons to hundreds of MeV to produce the SGRE. As 28 of the 30 SGRE events are accompanied by fast CMEs, it is likely that these protons are accelerated by the same shock that produces gradual SEPs. We find that the number of protons >500 MeV in the accompanying SEPs is typically about 50-100 times the number of protons that return to the Sun to produce the SGRE. There also appear to be correlations between the numbers of SEP and SGRE protons and durations of >100 MeV SEP proton and SGRE events. We find that for all SGRE events where there were flare observations, the accompanying impulsive X-radiation reached energies >100 keV. In a limited study of 18 solar events with CME speeds >800 km/s we also find that the median SEP proton flux is 25 times higher when flare hard X-rays exceed 100

  3. November 2013 Analysis of High Energy Electrons on the Japan Experimental Module (JEM: Kibo)

    Science.gov (United States)

    Badavi, Francis F.; Matsumoto, Haruhisa; Koga, Kiyokazu; Mertens, Christopher J.; Slaba, Tony C.; Norbury, John W.

    2015-01-01

    Albedo (precipitating/splash) electrons, created by galactic cosmic rays (GCR) interaction with the upper atmosphere move upwards away from the surface of the earth. In the past validation work these particles were often considered to have negligible contribution to astronaut radiation exposure on the International Space Station (ISS). Estimates of astronaut exposure based on the available Computer Aided Design (CAD) models of ISS consistently underestimated measurements onboard ISS when the contribution of albedo particles to exposure were neglected. Recent measurements of high energy electrons outside ISS Japan Experimental Module (JEM) using Exposed Facility (EF), Space Environment Data Acquisition Equipment - Attached Payload (SEDA-AP) and Standard DOse Monitor (SDOM), indicates the presence of high energy electrons at ISS altitude. In this presentation the status of these energetic electrons is reviewed and mechanism for the creation of these particles inside/outside South Atlantic Anomaly (SAA) region explained. In addition, limited dosimetric evaluation of these electrons at 600 MeV and 10 GeV is presented.

  4. Fractionation study: survival of mouse intestinal crypts to exposure of 60Co and 11 MeV electrons

    International Nuclear Information System (INIS)

    Coffey, C.W.

    1975-01-01

    The study was conducted to determine a statistical procedure for the quantification of time, dose, fraction relations for mouse intestinal crypt survival after fractionated Co-60 and 11-MeV electron irradiation. In the initial phase of the investigation CDF/1 male mice were exposed to fractionated Co-60 irradiation. A completely randomized experimental design with three factors, total time from initiation to completion of fractionation schedule, number of fractions, and total dose was utilized. The experimental animals were irradiated with a Co-60 panoramic irradiator unit at an absorbed dose rate of approximately 51 rads per minute. Two days after completion of the fractionation schedule, the experimental animals were sacrificed by cervical dislocation. Sections of intestinal jejunum were resected and routine histological preparations performed. The surviving crypts were scored with a compound microscope using a quantitative counting technique. The resulting crypt survival was observed to increase for increasing total times and fraction numbers

  5. Calculation of the energy spectrum of atmospheric gamma-rays between 1 and 1000 MeV

    International Nuclear Information System (INIS)

    Martin, I.M.; Dutra, S.L.G.; Palmeira, R.A.R.

    The energy spectrum of atmospheric gamma-rays at 4 g/cm 2 has been calculated for cut-off rigidities of 4.5, 10 and 16 GV. The considered processes for the production of these gamma-rays were the π 0 decay plus the bremsstrahlung from primary, secondary like splash and re-entrant albedo electrons. The calculations indicated that the spectrum could be fitted to a power law in energy, with the exponential index varying from 1.1 in the energy range 1 - 10 MeV, to 1.4 in the energy range 10 - 200 MeV and 1.8 in the energy range 200 - 1000 MeV. These results are discussed [pt

  6. Effect of Ge, Sn, Sb on the resistance to swelling of austenitic alloys irradiated by 1 MeV electrons

    International Nuclear Information System (INIS)

    Dubuisson, P.; Levy, V.; Seran, J.L.

    1987-01-01

    The effect of new solute elements namely Ge, Sn and Sb on the void swelling resistance of austenitic alloys irradiated with 1 MeV electrons has been studied. Except for tin in Ti-modified 316, all solute improve the swelling resistance of base alloys. Tin addition shifts the swelling peak of 316 S.S. to high temperature. In fact, these solute additions have the same qualitative effect on the swelling components: they enhance the void density and decrease strongly void growth rate. This effect is opposite to the one of usual swelling inhibitors such as Si or Ti which decrease the void density. We have explained this influence on the void nucleation and void growth by introducing a strong interaction between vacancies and solute atoms in a void growth model

  7. Theoretical detection limit of PIXE analysis using 20 MeV proton beams

    Science.gov (United States)

    Ishii, Keizo; Hitomi, Keitaro

    2018-02-01

    Particle-induced X-ray emission (PIXE) analysis is usually performed using proton beams with energies in the range 2∼3 MeV because at these energies, the detection limit is low. The detection limit of PIXE analysis depends on the X-ray production cross-section, the continuous background of the PIXE spectrum and the experimental parameters such as the beam currents and the solid angle and detector efficiency of X-ray detector. Though the continuous background increases as the projectile energy increases, the cross-section of the X-ray increases as well. Therefore, the detection limit of high energy proton PIXE is not expected to increase significantly. We calculated the cross sections of continuous X-rays produced in several bremsstrahlung processes and estimated the detection limit of a 20 MeV proton PIXE analysis by modelling the Compton tail of the γ-rays produced in the nuclear reactions, and the escape effect on the secondary electron bremsstrahlung. We found that the Compton tail does not affect the detection limit when a thin X-ray detector is used, but the secondary electron bremsstrahlung escape effect does have an impact. We also confirmed that the detection limit of the PIXE analysis, when used with 4 μm polyethylene backing film and an integrated beam current of 1 μC, is 0.4∼2.0 ppm for proton energies in the range 10∼30 MeV and elements with Z = 16-90. This result demonstrates the usefulness of several 10 MeV cyclotrons for performing PIXE analysis. Cyclotrons with these properties are currently installed in positron emission tomography (PET) centers.

  8. 7.5 MeV High Average Power Linear Accelerator System for Food Irradiation Applications

    International Nuclear Information System (INIS)

    Eichenberger, Carl; Palmer, Dennis; Wong, Sik-Lam; Robison, Greg; Miller, Bruce; Shimer, Daniel

    2005-09-01

    In December 2004 the US Food and Drug Administration (FDA) approved the use of 7.5 MeV X-rays for irradiation of food products. The increased efficiency for treatment at 7.5 MeV (versus the previous maximum allowable X-ray energy of 5 MeV) will have a significant impact on processing rates and, therefore, reduce the per-package cost of irradiation using X-rays. Titan Pulse Sciences Division is developing a new food irradiation system based on this ruling. The irradiation system incorporates a 7.5 MeV electron linear accelerator (linac) that is capable of 100 kW average power. A tantalum converter is positioned close to the exit window of the scan horn. The linac is an RF standing waveguide structure based on a 5 MeV accelerator that is used for X-ray processing of food products. The linac is powered by a 1300 MHz (L-Band) klystron tube. The electrical drive for the klystron is a solid state modulator that uses inductive energy store and solid-state opening switches. The system is designed to operate 7000 hours per year. Keywords: Rf Accelerator, Solid state modulator, X-ray processing

  9. A new Predictive Model for Relativistic Electrons in Outer Radiation Belt

    Science.gov (United States)

    Chen, Y.

    2017-12-01

    Relativistic electrons trapped in the Earth's outer radiation belt present a highly hazardous radiation environment for spaceborne electronics. These energetic electrons, with kinetic energies up to several megaelectron-volt (MeV), manifest a highly dynamic and event-specific nature due to the delicate interplay of competing transport, acceleration and loss processes. Therefore, developing a forecasting capability for outer belt MeV electrons has long been a critical and challenging task for the space weather community. Recently, the vital roles of electron resonance with waves (including such as chorus and electromagnetic ion cyclotron) have been widely recognized; however, it is still difficult for current diffusion radiation belt models to reproduce the behavior of MeV electrons during individual geomagnetic storms, mainly because of the large uncertainties existing in input parameters. In this work, we expanded our previous cross-energy cross-pitch-angle coherence study and developed a new predictive model for MeV electrons over a wide range of L-shells inside the outer radiation belt. This new model uses NOAA POES observations from low-Earth-orbits (LEOs) as inputs to provide high-fidelity nowcast (multiple hour prediction) and forecast (> 1 day prediction) of the energization of MeV electrons as well as the evolving MeV electron distributions afterwards during storms. Performance of the predictive model is quantified by long-term in situ data from Van Allen Probes and LANL GEO satellites. This study adds new science significance to an existing LEO space infrastructure, and provides reliable and powerful tools to the whole space community.

  10. The clinical meaning of radiodermatitis considering the surface dose of supervoltage electron beam

    International Nuclear Information System (INIS)

    Hiraki, Tatsunosuke; Rikimaru, Shigeho; Kakishita, Masao; Kuranishi, Makoto.

    1975-01-01

    In our experience using supervoltage betatron electron beam, the skin surface dose of the electron decreased when the energy became either greater of less than 18 MeV. When we considered 18 MeV to be a 100% dose, the dose with 4 MeV, which was the least amount, corresponded to 81% of the dose. The skin surface dose of 10 MeV betatron electrons or more became greater than the 90% standard tumor dose. An external irradiation of more than 10 MeV should not be applied to neoplasms of which the curative ratio is less than 1.0. Therefore another methods such as intraoperative irradiation, should be used. The surface skin dose about 4-6 MeV betatron postoperative irradiation, particularly after resection of breast cancer, was less than the skin dose with 10 MeV. Close care should be taken to prevent hot lesions which are caused by duplication of irradiation fields. It should be kept in mind that the late effects of hot lesions caused by electron beam irradiation with an energy of 10 MeV or more are serious. (Kashu, E.)

  11. Microstructural parameters in 8 MeV Electron irradiated Bombyx mori silk fibers by wide-angle X-ray scattering studies (WAXS)

    International Nuclear Information System (INIS)

    Halabhavi, Sangappa

    2009-01-01

    The present work looks into the microstructural modification in Bombyx mori silk fibers, induced by electron irradiation. The irradiation process was performed in air at room temperature by use of 8 MeV electron accelerators at different doses: 0, 25, 50, 75 and 100 kGy respectively. Irradiation of polymer can be used to crosslink or degrade the desired component or to fixate the polymer morphology. The changes in microstructural parameters in these natural polymer fibers have been studied using wide angle X-ray scattering (WAXS) method. The crystal imperfection parameters such as crystallite size , lattice strain (g in %) and enthalpy (a * ) have been determined by line profile analysis (LPA) using Fourier method of Warren. Exponential, Lognormal and Reinhold functions for the column length distributions have been used for the determination of these parameters. The goodness of the fit and the consistency of these results suggest that the exponential distribution gives much better results, even though lognormal distribution has been widely used to estimate the similar stacking faults in metal oxide compounds. (author)

  12. Test of virtual photon theory. [Cross sections, square-well potential, 0 to 300 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Dressler, E T; Tomusiak, E L [Saskatchewan Univ., Saskatoon (Canada). Saskatchewan Accelerator Lab.

    1976-11-30

    In order to extract a photodisintegration cross section in the c.m. system from an electrodisintegration cross section measured in the lab system, one has to assume that the electrons are mostly scattered forward and that the monopole contributions are negligible. To test the validity of these approximations, a square well potential was assumed for the initial and final states and the photodisintegration cross section was calculated exactly within this model. These results were then compared with the results one would obtain using the virtual photon theory approximations for electron energies of 0-300 MeV and excitation energies up to 40 MeV. In comparing the two results, it is shown how and why the virtual photon theory approximations fail in certain kinematical regions.

  13. Pulse compression system for the ANL 20 MeV linac

    International Nuclear Information System (INIS)

    Mavrogenes, G.; Norem, J.; Simpson, J.

    1986-01-01

    This paper describes the pulse compression system being built on the Argonne 20 MeV electron linac. The system is designed to rotate the bunch from the present measured pulse length of 38 psec FWHM, to pulse lengths of 5 to 6 ps with the large instantaneous currents (1 to 4 kA) possible instantaneous current. This system was necessary to extend the study of reactive fragments of molecules to the time scale of a few picoseconds, in particular to examine the chemistry of electrons and ions before and during relaxation of the surrounding media. These experiments are not sensitive to the beam energy spread, High Energy Physics experiments studying wake fields have also been proposed using the short bunches and the facility was designed so that the wake field experiment could share the beam bunching system. The 20 MeV electron linac uses a double gap, 12th subharmonic prebuncher together with a one wavelength 1.3 Ghz prebuncher to produce a single pulse of 38 ps from one occupied rf bucket. Beam emittances of 15.7 mmmr have been measured for 40 nC of accelerated charge and 8 mmmr at 10 nC. The energy spread of dE/E = 1% (FWHM) has been measured at 40 nC. Thus the accelerated beam has excellent time structure, high current, and good emittance

  14. Possible explanation of the electron positron anomaly at 17 MeV in {sup 8}Be transitions through a light pseudoscalar

    Energy Technology Data Exchange (ETDEWEB)

    Ellwanger, Ulrich [Laboratoire de Physique Théorique, UMR 8627, CNRS,Université de Paris-Sud, University Paris-Saclay,Campus d’Orsay, 91405 Orsay (France); School of Physics and Astronomy, University of Southampton,Highfield, Southampton SO17 1BJ (United Kingdom); Moretti, Stefano [School of Physics and Astronomy, University of Southampton,Highfield, Southampton SO17 1BJ (United Kingdom)

    2016-11-08

    We estimate the values of Yukawa couplings of a light pseudoscalar A with a mass of about 17 MeV, which would explain the {sup 8}Be anomaly observed in the Atomki pair spectrometer experiment. The resulting couplings of A to up and down type quarks are about 0.3 times the coupling of the standard Higgs boson. Then constraints from K and B decays require that loop contributions to flavour changing vertices cancel at least at the 10% level. Constraints from beam dump experiments require the coupling of A to electrons to be larger than about 4 times the coupling of the standard Higgs boson, leading to a short enough A life time consistent with an explanation of the anomaly.

  15. Wave function of an electron infinitely moving in the field of a one-dimensional layered structure

    International Nuclear Information System (INIS)

    Khachatrian, A.Zh.; Andreasyan, A.G.; Mgerian, G.G.; Badalyan, V.D.

    2003-01-01

    A method for finding the wave function of an electron infinitely moving in the field of an arbitrary layered structure bordered on both sides with two different semi infinite media is proposed. It is shown that this problem in the general form can be reduced to the solution of some system of linear finite-difference equations. The proposed approach is discussed in detail for the case of a periodic structure

  16. 0 degree binary encounter electron production in 30-MeV Oq++H2, He, O2, Ne, and Ar collisions

    International Nuclear Information System (INIS)

    Zouros, T.J.; Wong, K.L.; Grabbe, S.; Hidmi, H.I.; Richard, P.; Montenegro, E.C.; Sanders, J.M.; Liao, C.; Hagmann, S.; Bhalla, C.P.

    1996-01-01

    Double-differential cross sections (DDCS close-quote s) for the production of binary encounter electrons (BEE close-quote s) were measured for collisions of 30-MeV O q+ projectiles with H 2 , He, O 2 , Ne, and Ar targets with q=4 endash 8 and an electron ejection angle of θ=0 degree with respect to the beam direction. Particular interest focused on (a) the evaluation of the contributions of the different electron subshells of the multielectron targets, O 2 , Ne, and Ar; (b) the study of the well-known enhancement of the BEE DDCS close-quote s with decreasing projectile charge-state q; here this dependence was tested for higher collision energies and new targets; (c) the study of the dependence of the BEE peak energy on the particular target and projectile charge state. Results were analyzed in terms of the impulse approximation, in which target electrons in the projectile frame undergo 180 degree elastic scattering in the field of the projectile ion. The electron scattering calculations were performed in a partial-wave treatment using the Hartree-Fock model. Good agreement with the data was found for the H 2 and He targets, while for the multielectron targets O 2 , Ne, and Ar only electrons whose velocity was lower than the projectile velocity needed to be included for good agreement. All measured BEE DDCS close-quote s were found to increase with decreasing projectile charge state, in agreement with other recent BEE results. The BEE peak energies were found to be independent of the projectile charge state for all targets utilized. copyright 1996 The American Physical Society

  17. 120 MeV Ag ion induced effects in Au/HfO2/Si MOSCAPs

    Science.gov (United States)

    Manikanthababu, N.; Prajna, K.; Pathak, A. P.; Rao, S. V. S. Nageswara

    2018-05-01

    HfO2/Si thinfilms were deposited by RF sputtering technique. 120 MeV Ag ion irradiation has been used to study the electrical properties of Au/HfO2/Si MOSCAPs. SHI (120 MeV Ag) induced annealing, defects creation and intermixing effects on the electrical properties of these systems have been studied. Here, we have observed that the high electronic excitation can cause a significant reduction of leakage currents in these MOSCAP devices. Various quantum mechanical tunneling phenomenon has been observed from the I-V characteristics.

  18. Effect of 6 MeV electrons on luminescence properties of Y{sub 2}O{sub 3}:Tb{sup 3+} nanophosphors

    Energy Technology Data Exchange (ETDEWEB)

    Sunitha, D.V., E-mail: sunithaprasad8@gmail.com [School of Physics, Reva University, Yelahanka, Bangalore 560064 (India); Nagabhushana, H. [Prof. C.N.R. Rao Centre for Advanced Materials Research, Tumkur University, Tumkur 572103 (India); Hareesh, K., E-mail: appi.2907@gmail.com [Department of Physics, Savitribai Phule Pune University, Pune 411007 (India); Bhoraskar, V.N. [Department of Physics, Savitribai Phule Pune University, Pune 411007 (India); Dhole, S.D., E-mail: sanjay@physics.unipune.ac.in [Department of Physics, Savitribai Phule Pune University, Pune 411007 (India)

    2016-09-15

    Y{sub 2}O{sub 3}:Tb{sup 3+} nanophosphors were synthesized by solution combustion technique and irradiated with 6 MeV energetic electrons in the fluence range 2–10×10{sup 13} e{sup −}cm{sup −2}. Powder X-ray diffraction (PXRD) patterns confirm cubic phase of Y{sub 2}O{sub 3}. The crystallite size was estimated using Scherrer method and was found to be in the order of ~39 nm. SEM micrographs revealed the formation of non-uniform spherical shaped particles for higher electron fluence. Photoluminescence spectra (PL) of pristine and Tb{sup 3+} doped Y{sub 2}O{sub 3} were recorded in the fluence range 2–10×10{sup 13} e{sup −}cm{sup −2}. PL intensity was found to increase up to 4×10{sup 13} e{sup −}cm{sup −2} and thereafter it decreases with further increase in electron fluence. This may be attributed to lattice disorder produced by dense electronic excitation under electron irradiation. The characteristic emission peaks of Tb{sup 3+} were observed at ~ 484–490 nm ({sup 5}D{sub 4}→{sup 7}F{sub 6}), 548 nm ({sup 5}D{sub 4}→{sup 7}F{sub 5}) and 587 nm ({sup 5}D{sub 4}→{sup 7}F{sub 4}) at excited wavelength 397 nm. Two TL glow peaks were recorded in both pristine and electron irradiated samples indicate that two types of traps were created. The color co-ordinate values (x, y) were located in the green region of the CIE diagram suggests that electron irradiated Y{sub 2}O{sub 3}:Tb{sup 3+} phosphor could be used in white LEDs.

  19. Precision electron polarimetry

    International Nuclear Information System (INIS)

    Chudakov, E.

    2013-01-01

    A new generation of precise Parity-Violating experiments will require a sub-percent accuracy of electron beam polarimetry. Compton polarimetry can provide such accuracy at high energies, but at a few hundred MeV the small analyzing power limits the sensitivity. Mo/ller polarimetry provides a high analyzing power independent on the beam energy, but is limited by the properties of the polarized targets commonly used. Options for precision polarimetry at 300 MeV will be discussed, in particular a proposal to use ultra-cold atomic hydrogen traps to provide a 100%-polarized electron target for Mo/ller polarimetry

  20. Cross sections of electron loss and capture for beams of O+ in water vapor from the energy range of 0,2 to 1,2 MeV

    International Nuclear Information System (INIS)

    Oliveira, Vitor Jesus de

    2015-01-01

    The study of the interactions between atoms and molecules is important for the knowledge of the cross sections of the processes that contribute to the deposition of energy by charged particle beams used in radiotherapy planning and transport particle simulation codes. Heavy ions, such as oxygen, induce many cellular and molecular damages in human cells.as a result of interaction between the projectile and atoms and molecules. The use of proton and carbon as the projectile interacting with water molecules is well characterized, however there are few studies with oxygen ions. In this work we are interested in the study of electron loss (projectile ionization) and electron capture with charge state 1+. The Pelletron accelerator of 1.7 MeV from the Federal University of Rio de Janeiro housed in the Atomic and Molecular collisions Laboratory (LACAM) has been used, which can accelerate atomic and molecular ions up to speeds of the order of hundredths of light speed, and consists of the source of negative ions, the Wien filter, the accelerator itself and the magnet load selector. The detection device used to evaluate the processes of interaction (capture and loss) between the beam of the O + and the water molecule is a Microchannel Plate (MCP) at the position sensitive anode. The collisions of O + beans are being studied in the range of 0.2 to 1.2 MeV with water vapor (Z = 10). Were obtained the respective absolute cross sections for electron loss and electron capture and compared with the cross sections of the molecule methane (CH4 → Z = 10), the isoelectronic water molecule. The experimental results show an agreement between the measurements with water and methane. Comparisons were made with results of theoretical models for electron loss using the 'Free Collision Model' and for capture the Bohr and Lindhard model. The theoretical results for electron loss show an agreement of experimental data with the model used. The model of Bohr and Lindhard describes

  1. Calculated and measured dose distribution in electron and X-ray irradiated water phantom

    CERN Document Server

    Ziaie, F; Bulka, S; Afarideh, H; Hadji-Saeid, S M

    2002-01-01

    The Bremsstrahlung yields produced by incident electrons on a tantalum converter have been calculated by using a Monte-Carlo computer code. The tantalum thickness as an X-ray converter was optimized for 2, 2.5, 5, 7.5, and 10 MeV electron beams. The dose distribution in scanning and conveyor direction for both 2 MeV electron and X-ray converted from 2 MeV electron beam have been calculated and compared with experimental results. The economical aspects of low energy electron conversion were discussed as well.

  2. Near-real time forecasts of MeV protons based on sub-relativistic electrons: communicating the outputs to the end users

    Science.gov (United States)

    Sarlanis, Christos; Heber, Bernd; Labrenz, Johannes; Kühl, Patrick; Marquardt, Johannes; Dimitroulakos, John; Papaioannou, Athanasios; Posner, Arik

    2017-04-01

    Solar Energetic Particle (SEP) events are one of the most important elements of space weather. Given that the complexity of the underlying physical processes of the acceleration and propagation of SEP events is still a very active research area, the prognosis of SEP event occurrence and their corresponding characteristics remains challenging. In order to provide up to an hour warning time before these particles arrive at Earth, relativistic electron and below 50 MeV proton data from the Electron Proton Helium Instrument (EPHIN) on SOHO were used to implement the 'Relativistic Electron Alert System for Exploration (REleASE)'. The REleASE forecasting scheme was recently rewritten in the open access programming language PYTHON and will be made publicly available. As a next step, along with relativistic electrons (v > 0.9 c) provided by SOHO, near-relativistic (v work, we demonstrate the real-time outputs derived by the end user from the REleASE using both SOHO/EPHIN and ACE/EPAM. We further, show a user friendly illustration of the outputs that make use of a "traffic light" to monitor the different warning stages: quiet, warning, alert offering a simple guidance to the end users. Finally, the capabilities offered by this new system, accessing both the pictorial and textural outputs REleASE are being presented. This work has received funding from the European Union's Horizon 2020 research and innovation programme under grant agreement No 637324.

  3. Cherenkov radiation by an electron bunch that moves in a vacuum above a left-handed material

    International Nuclear Information System (INIS)

    Averkov, Yu.O.; Yakovenko, V.M.

    2005-01-01

    Cherenkov radiation by a nonrelativistic electron bunch that moves above an interface of a vacuum-left-handed material has been investigated theoretically. The electron density of the bunch is described by a Gauss distribution. Cherenkov radiation for the frequency range where the refractive index is negative is shown to lead to simultaneous excitation of both bulk and surface electromagnetic waves over one and the same frequency range. In this case the wave vector magnitude in the plane of the interface of surface electromagnetic waves is larger than the corresponding wave vector magnitude of bulk electromagnetic waves. The energy flows in a left-handed material have been calculated. The spectral density and the radiation pattern have been investigated

  4. Development and application of compact and on-chip electron linear accelerators for dynamic tracking cancer therapy and DNA damage/repair analysis

    Science.gov (United States)

    Uesaka, M.; Demachi, K.; Fujiwara, T.; Dobashi, K.; Fujisawa, H.; Chhatkuli, R. B.; Tsuda, A.; Tanaka, S.; Matsumura, Y.; Otsuki, S.; Kusano, J.; Yamamoto, M.; Nakamura, N.; Tanabe, E.; Koyama, K.; Yoshida, M.; Fujimori, R.; Yasui, A.

    2015-06-01

    We are developing compact electron linear accelerators (hereafter linac) with high RF (Radio Frequency) frequency (9.3 GHz, wavelength 32.3 mm) of X-band and applying to medicine and non-destructive testing. Especially, potable 950 keV and 3.95 MeV linac X-ray sources have been developed for on-site transmission testing at several industrial plants and civil infrastructures including bridges. 6 MeV linac have been made for pinpoint X-ray dynamic tracking cancer therapy. The length of the accelerating tube is ∼600 mm. The electron beam size at the X-ray target is less than 1 mm and X-ray spot size at the cancer is less than 3 mm. Several hardware and software are under construction for dynamic tracking therapy for moving lung cancer. Moreover, as an ultimate compact linac, we are designing and manufacturing a laser dielectric linac of ∼1 MeV with Yr fiber laser (283 THz, wavelength 1.06 pm). Since the wavelength is 1.06 μm, the length of one accelerating strcture is tens pm and the electron beam size is in sub-micro meter. Since the sizes of cell and nuclear are about 10 and 1 μm, respectively, we plan to use this “On-chip” linac for radiation-induced DNA damage/repair analysis. We are thinking a system where DNA in a nucleus of cell is hit by ∼1 μm electron or X-ray beam and observe its repair by proteins and enzymes in live cells in-situ.

  5. Ultrashort megaelectronvolt positron beam generation based on laser-accelerated electrons

    Science.gov (United States)

    Xu, Tongjun; Shen, Baifei; Xu, Jiancai; Li, Shun; Yu, Yong; Li, Jinfeng; Lu, Xiaoming; Wang, Cheng; Wang, Xinliang; Liang, Xiaoyan; Leng, Yuxin; Li, Ruxin; Xu, Zhizhan

    2016-03-01

    Experimental generation of ultrashort MeV positron beams with high intensity and high density using a compact laser-driven setup is reported. A high-density gas jet is employed experimentally to generate MeV electrons with high charge; thus, a charge-neutralized MeV positron beam with high density is obtained during laser-accelerated electrons irradiating high-Z solid targets. It is a novel electron-positron source for the study of laboratory astrophysics. Meanwhile, the MeV positron beam is pulsed with an ultrashort duration of tens of femtoseconds and has a high peak intensity of 7.8 × 1021 s-1, thus allows specific studies of fast kinetics in millimeter-thick materials with a high time resolution and exhibits potential for applications in positron annihilation spectroscopy.

  6. Electron Cooling of RHIC

    CERN Document Server

    Ben-Zvi, Ilan; Barton, Donald; Beavis, Dana; Blaskiewicz, Michael; Bluem, Hans; Brennan, Joseph M; Bruhwiler, David L; Burger, Al; Burov, Alexey; Burrill, Andrew; Calaga, Rama; Cameron, Peter; Chang, Xiangyun; Cole, Michael; Connolly, Roger; Delayen, Jean R; Derbenev, Yaroslav S; Eidelman, Yury I; Favale, Anthony; Fedotov, Alexei V; Fischer, Wolfram; Funk, L W; Gassner, David M; Hahn, Harald; Harrison, Michael; Hershcovitch, Ady; Holmes, Douglas; Hseuh Hsiao Chaun; Johnson, Peter; Kayran, Dmitry; Kewisch, Jorg; Kneisel, Peter; Koop, Ivan; Lambiase, Robert; Litvinenko, Vladimir N; MacKay, William W; Mahler, George; Malitsky, Nikolay; McIntyre, Gary; Meng, Wuzheng; Merminga, Lia; Meshkov, Igor; Mirabella, Kerry; Montag, Christoph; Nagaitsev, Sergei; Nehring, Thomas; Nicoletti, Tony; Oerter, Brian; Parkhomchuk, Vasily; Parzen, George; Pate, David; Phillips, Larry; Preble, Joseph P; Rank, Jim; Rao, Triveni; Rathke, John; Roser, Thomas; Russo, Thomas; Scaduto, Joseph; Schultheiss, Tom; Sekutowicz, Jacek; Shatunov, Yuri; Sidorin, Anatoly O; Skrinsky, Aleksander Nikolayevich; Smirnov, Alexander V; Smith, Kevin T; Todd, Alan M M; Trbojevic, Dejan; Troubnikov, Grigory; Wang, Gang; Wei, Jie; Williams, Neville; Wu, Kuo-Chen; Yakimenko, Vitaly; Zaltsman, Alex; Zhao, Yongxiang; ain, Animesh K

    2005-01-01

    We report progress on the R&D program for electron-cooling of the Relativistic Heavy Ion Collider (RHIC). This electron cooler is designed to cool 100 GeV/nucleon at storage energy using 54 MeV electrons. The electron source will be a superconducting RF photocathode gun. The accelerator will be a superconducting energy recovery linac. The frequency of the accelerator is set at 703.75 MHz. The maximum electron bunch frequency is 9.38 MHz, with bunch charge of 20 nC. The R&D program has the following components: The photoinjector and its photocathode, the superconducting linac cavity, start-to-end beam dynamics with magnetized electrons, electron cooling calculations including benchmarking experiments and development of a large superconducting solenoid. The photoinjector and linac cavity are being incorporated into an energy recovery linac aimed at demonstrating ampere class current at about 20 MeV. A Zeroth Order Design Report is in an advanced draft state, and can be found on the web at http://www.ags...

  7. Competition Between Radial Loss and EMIC Wave Scattering of MeV Electrons During Strong CME-shock Driven Storms

    Science.gov (United States)

    Hudson, M. K.; Jaynes, A. N.; Li, Z.; Malaspina, D.; Millan, R. M.; Patel, M.; Qin, M.; Shen, X.; Wiltberger, M. J.

    2017-12-01

    The two strongest storms of Solar Cycle 24, 17 March and 22 June 2015, provide a contrast between magnetospheric response to CME-shocks at equinox and solstice. The 17 March CME-shock initiated storm produced a stronger ring current response with Dst = - 223 nT, while the 22 June CME-shock initiated storm reached a minimum Dst = - 204 nT. The Van Allen Probes ECT instrument measured a dropout in flux for both events which can be characterized by magnetopause loss at higher L values prior to strong recovery1. However, rapid loss is seen at L 3 for the June storm at high energies with maximum drop in the 5.2 MeV channel of the REPT instrument coincident with the observation of EMIC waves in the H+ band by the EMFISIS wave instrument. The rapid time scale of loss can be determined from the 65 minute delay in passage of the Probe A relative to the Probe B spacecraft. The distinct behavior of lower energy electrons at higher L values has been modeled with MHD-test particle simulations, while the rapid loss of higher energy electrons is examined in terms of the minimum resonant energy criterion for EMIC wave scattering, and compared with the timescale for loss due to EMIC wave scattering which has been modeled for other storm events.2 1Baker, D. N., et al. (2016), Highly relativistic radiation belt electron acceleration, transport, and loss: Large solar storm events of March and June 2015, J. Geophys. Res. Space Physics, 121, 6647-6660, doi:10.1002/2016JA022502. 2Li, Z., et al. (2014), Investigation of EMIC wave scattering as the cause for the BARREL 17 January 2013 relativistic electron precipitation event: A quantitative comparison of simulation with observations, Geophys. Res. Lett., 41, 8722-8729, doi:10.1002/2014GL062273.

  8. Effects of 6 MeV electron irradiation on the electrical properties and device parameters of Al/Al2O3/TiO2/n-Si MOS capacitors

    International Nuclear Information System (INIS)

    Laha, P.; Banerjee, I.; Barhai, P.K.; Das, A.K.; Bhoraskar, V.N.; Mahapatra, S.K.

    2012-01-01

    Highlights: ► The electron irradiation effects make variation in the device parameters. ► The device parameters changes due to percentage of defects and charge trapping. ► Leakage current of Al/Al 2 O 3 /TiO 2 /n-Si changes due to interface dangling bonds. ► The leakage current mechanism of MOS structures is due to Poole–Frenkel effect. - Abstract: The effects of 6 MeV electron irradiation on the electrical properties and device parameter characteristics of Al/Al 2 O 3 /TiO 2 /n-Si metal–oxide–semiconductor capacitors have been studied. Twelve Al/Al 2 O 3 /TiO 2 /n-Si MOS capacitors were fabricated using r.f. magnetron sputtering and divided into four groups. The first group was not irradiated and treated as virgin. The rest were irradiated with 6 MeV electrons at doses 10, 20, and 30 kGy, maintaining the dose rate at ∼1 kGy/min. Variations in crystallinity of the virgin and irradiated capacitors were studied using grazing incident X-ray diffraction. The thickness and in-depth elemental distributions of individual layers were determined using secondary ion mass apectrometry. Capacitance–voltage, conductance–voltage and leakage current–voltage characteristics of the virgin and irradiated samples were studied. The device parameters (flat band voltage, surface charge density and interface trap density of the virgin and irradiated structures) were determined. The electrical properties of the capacitors were investigated and the Poole–Frenkel coefficient of the capacitors was determined from leakage current measurements. The leakage current mechanism has been explained.

  9. Radiological safety research of food irradiation with 7.5 MeV X-rays

    International Nuclear Information System (INIS)

    Yang Bin; Tang Weidong; Zhang Yue; Xu Tao; Jin Jianqiao; Ye Mingyang

    2012-01-01

    China and America both have 7.5 MeV high energy X-ray accelerator. The radiological safety of food irradiated with 7.5 MeV X-rays (bremsstrahlung) has been investigated. Samples of meat and meat ash were located in a large volume of fresh meat at the position of the highest photoneutron fluence and irradiated to an X-ray dose of 15 kGy, twice the maximum dose allowed by the US FDA for meat irradiation. An evaluation of the corresponding radiation exposure from ingestion of the irradiated product has been compared to natural background radiation. The paper concludes that the risk to individuals from intake of food irradiated with X-rays from 7.5 MeV electrons, even with a broad energy spectrum, would be trivial. The common target materials are Au, Ta and W. The U.S, requires only Au and Ta can be used as food irradiation target materials and China has not yet relevant provisions. The first 7.5 MeV accelerator for food irradiation in China is under built, and will do the explore research for the choice of target material. (authors)

  10. Use of an electron reflector to improve dose uniformity at the vertex during total skin electron therapy

    International Nuclear Information System (INIS)

    Peters, V.G.

    2000-01-01

    Purpose: The vertex of the scalp is always tangentially irradiated during total skin electron therapy (TSET). This study was conducted to determine the dose distribution at the vertex for a commonly used irradiation technique and to evaluate the use of an electron reflector, positioned above the head, as a means of improving the dose uniformity. Methods and Materials: Phantoms, simulating the head of a patient, were irradiated using our standard procedure for TSET. The technique is a six-field irradiation using dual angled electron beams at a treatment distance of 3.6 meters. Vertex dosimetry was performed using ionization methods and film. Measurements were made for an unmodified 6 MeV electron beam and for a 4 MeV beam obtained by placing an acrylic scattering plate in the beam line. Studies were performed to examine the effect of electron scattering on vertex dose when a lead reflector, 50 x 50 cm in area, was positioned above the phantom. Results: The surface dose at the vertex, in the absence of the reflector, was found to be less than 40% of the prescribed skin dose. Use of the lead reflector increased this value to 73% for the 6 MeV beam and 99% for the degraded 4 MeV beam. Significant improvements in depth dose were also observed. The dose enhancement is not strongly dependent on reflector distance or angulation since the reflector acts as a large source of broadly scattered electrons. Conclusion: The vertex may be significantly underdosed using standard techniques for total skin electron therapy. Use of an electron reflector improves the dose uniformity at the vertex and may reduce or eliminate the need for supplemental irradiation

  11. Laser-induced electron--ion recombination used to study enhanced spontaneous recombination during electron cooling

    International Nuclear Information System (INIS)

    Schramm, U.; Wolf, A.; Schuess ler, T.; Habs, D.; Schwalm, D.; Uwira, O.; Linkemann, J.; Mueller, A.

    1997-01-01

    Spontaneous recombination of highly charged ions with free electrons in merged velocity matched electron and ion beams has been observed in earlier experiments to occur at rates significantly higher than predicted by theoretical estimates. To study this enhanced spontaneous recombination, laser induced recombination spectra were measured both in velocity matched beams and in beams with well defined relative velocities, corresponding to relative electron-ion detuning energies ranging from 1 meV up to 6.5 meV where the spontaneous recombination enhancement was found to be strongly reduced. Based on a comparison with simplified calculations, the development of the recombination spectra for decreasing detuning energies indicates additional contributions at matched velocities which could be related to the energy distribution of electrons causing the spontaneous recombination rate enhancement

  12. Technology for Fissionable Materials Detection by Use of 100 MeV Variable Linac

    CERN Document Server

    Karasyov, Sergey P; Dovbnja, Anatoliy N; Eran, L; Kiryukhin, Nikolay M; Melnik, Yu M; Ran'iuk, Yu; Shlyakhov, Il'ya N; Trubnikov, Sergiy V

    2005-01-01

    A new concept for a two-step facility to increase the accuracy/reliability of detecting heavily shielded fissionable materials (FM) in marine containers is presented. The facility will detect FM in two steps. An existing dual-view; dual-energy X-ray scanner, which is based on 7 MeV electron accelerator, will select the suspicious places inside container. The linac with variable energy (up to 100 MeV) will be used for the second step. The technology will detect fissionable nuclei by gamma induced fission reactions and delayed neutron registration. A little-known Ukrainian experimental data obtained in Chernobil' clean-up program will be presented to ground proposed concept. The theoretical calculations of neutron fluxes scale these results to marine container size. Modified GEANT code for electron/gamma penetration and authors' own software for neutron yield/penetration are used for these calculations. Available facilities (X-ray scanners; linac; detectors), which will be used for concept proof, are described....

  13. Measured neutron carbon kerma factors from 14.1 MeV to 18 MeV

    International Nuclear Information System (INIS)

    Deluca, P.M.; Barschall, H.H.; McDonald, J.C.

    1985-01-01

    For A-150 tissue-equivalent plastic, the total neutron kerma is dominated by the hydrogen kerma. Tissue kerma is inferred with reasonable accuracy by normalization to the kerma factor ratio between tissue and A-150 plastic. Because of the close match in the hydrogen abundance in these materials, the principal uncertainty is due to the kerma factors of carbon and oxygen. We have measured carbon kerma factor values of 0.183+-0.015 10 -8 cGy cm 2 and 0.210+-0.016 10 -8 cGy cm 2 at 14.1-MeV and 15-MeV neutron energy, respectively. A preliminary value of 0.297+-0.03 10 -8 cGy cm 2 has been determined at 17.9 MeV. A recent microscopic cross section measurement of the (n,n'3α) reaction in carbon at 14.1-MeV energy gives a kerma factor of 0.184+-0.019 10 -8 cGy cm 2 in agreement with the present result

  14. Large scale silver nanowires network fabricated by MeV hydrogen (H+) ion beam irradiation

    International Nuclear Information System (INIS)

    S, Honey; S, Naseem; A, Ishaq; M, Maaza; M T, Bhatti; D, Wan

    2016-01-01

    A random two-dimensional large scale nano-network of silver nanowires (Ag-NWs) is fabricated by MeV hydrogen (H + ) ion beam irradiation. Ag-NWs are irradiated under H +  ion beam at different ion fluences at room temperature. The Ag-NW network is fabricated by H + ion beam-induced welding of Ag-NWs at intersecting positions. H +  ion beam induced welding is confirmed by transmission electron microscopy (TEM) and scanning electron microscopy (SEM). Moreover, the structure of Ag NWs remains stable under H +  ion beam, and networks are optically transparent. Morphology also remains stable under H +  ion beam irradiation. No slicings or cuttings of Ag-NWs are observed under MeV H +  ion beam irradiation. The results exhibit that the formation of Ag-NW network proceeds through three steps: ion beam induced thermal spikes lead to the local heating of Ag-NWs, the formation of simple junctions on small scale, and the formation of a large scale network. This observation is useful for using Ag-NWs based devices in upper space where protons are abandoned in an energy range from MeV to GeV. This high-quality Ag-NW network can also be used as a transparent electrode for optoelectronics devices. (paper)

  15. Deep-level defects introduced by 1 MeV electron radiation in AlInGaP for multijunction space solar cells

    International Nuclear Information System (INIS)

    Lee, H.S.; Yamaguchi, M.; Ekins-Daukes, N. J.; Khan, A.; Takamoto, T.; Agui, T.; Kamimura, K.; Kaneiwa, M.; Imaizumi, M.; Ohshima, T.; Itoh, H.

    2005-01-01

    Presented in this paper are 1 MeV electron irradiation effects on wide-band-gap (1.97 eV) (Al 0.08 Ga 0.92 ) 0.52 In 0.48 P diodes and solar cells. The carrier removal rate estimated in p-AlInGaP with electron fluence is about 1 cm -1 , which is lower than that in InP and GaAs. From high-temperature deep-level transient spectroscopy measurements, a deep-level defect center such as majority-carrier (hole) trap H2 (E ν +0.90±0.05 eV) was observed. The changes in carrier concentrations (Δp) and trap densities as a function of electron fluence were compared, and as a result the total introduction rate, 0.39 cm -1 , of majority-carrier trap centers (H1 and H2) is different from the carrier removal rate, 1 cm -1 , in p-AlInGaP. From the minority-carrier injection annealing (100 mA/cm 2 ), the annealing activation energy of H2 defect is ΔE=0.60 eV, which is likely to be associated with a vacancy-phosphorus Frenkel pair (V p -P i ). The recovery of defect concentration and carrier concentration in the irradiated p-AlInGaP by injection relates that a deep-level defect H2 acts as a recombination center as well as compensator center

  16. Dragon-I Linear Induction Electron Accelerator

    International Nuclear Information System (INIS)

    Ding Bonan; Deng Jianjun; Wang Huacen; Cheng Nian'an; Dai Guangsen; Zhang Linwen; Liu Chengjun; Zhang Wenwei; Li Jin; Zhang Kaizhi

    2005-01-01

    Dragon-I is a linear induction electron accelerator. This facility consists of a 3.6 MeV injector, 38 meter beam transport line and 16 MeV induction accelerator powered by high voltage generators, including 8 Marx generators and 48 Blumlein lines. This paper describes the physics design, development and experimental results of Dragon-I. The key technology is analyzed in the accelerator development, and the design requirements and operation of the major subsystems are presented. The experimental results show Dragon-I generates an 18-20 MeV, 2.5 kA, 70 ns electron beam. The X-ray spot size is about 1.2 mm and dose level about 0.103 C/kg at 1 meter. (authors)

  17. Measurement and production of electron deflection using a sweeping magnetic device in radiotherapy

    International Nuclear Information System (INIS)

    Damrongkijudom, N.; Oborn, B.; Rosenfeld, A.; Butson, M.

    2006-01-01

    The deflection and removal of high energy electrons produced by a medical linear accelerator has been attained by a Neodymium Iron Boron (NdFeB) permanent magnetic deflector device. This work was performed in an attempt to confirm the theoretical amount of electron deflection which could be produced by a magnetic field for removal of electrons from a clinical x-ray beam. This was performed by monitoring the paths of mostly monoenergetic clinical electron beams (6MeV to 20MeV) swept by the magnetic fields using radiographic film and comparing to first order deflection models. Results show that the measured deflection distance for 6 MeV electrons was 18 ± 6 cm and the calculated deflection distance was 21.3 cm. For 20 MeV electrons, this value was 5 ± 2 cm for measurement and 5.1 cm for calculation. The magnetic fields produced can thus reduce surface dose in treatment regions of a patient under irradiation by photon beams and we can predict the removal of all electron contaminations up to 6 MeV from a 6 MV photon beam with the radiation field size up to 10 x 10 cm 2 . The model can also estimate electron contamination still present in the treatment beam at larger field sizes

  18. The electron accelerator for FELIX [Free Electron Laser for Infrared eXperiments

    International Nuclear Information System (INIS)

    Amersfoort, P.W. van; Geer, C.A.J. van der; Meer, A.F.G. van der; Bruinsma, P.J.T.; Hoekstra, R.; Kroes, F.B.; Luyckx, G.; Noomen, J.G.; Poole, M.W.; Saxon, G.

    1989-01-01

    The authors discuss the design of the electron accelerator for the Free Electron Laser for Infrared eXperiments (FELIX), which is meant to provide the Dutch science community with a rapidly tunable source of infrared radiation. The first stage of the project will (at least) cover the wavelength range between 8 and 80 μm. The accelerator consists of a triode with a grid modulated at 1 GHz, a 3.8-MeV buncher, and two travelling-wave S-band linac structures, with which 70-A, 3-ps bunches are accelerated to an energy between 15 and 4-5 MeV. The system has been designed to minimize the energy spread in the electron beam. 8 refs., 2 figs., 1 tab

  19. Measurements of pp→π+d between 398 MeV and 572 MeV

    International Nuclear Information System (INIS)

    Aebischer, D.; Favier, B.; Greeniaus, L.G.; Hess, R.; Junod, A.; Lechanoine, C.; Nikles, J.-C.; Rapin, D.; Werren, D.W.

    1976-01-01

    The reaction pp→π + d was studied at incident proton energies of 398, 455, 497, 530 and 572 MeV. Measurements of dsigma/dΩ at 455 and 572 MeV show the presence of pion d-waves in the pion-deuteron system. Asymmetry measurements yield similar conclusions. Total cross-section measurements agree with recent fits to earlier data. (Auth.)

  20. Ultrafast Science Opportunities with Electron Microscopy

    Energy Technology Data Exchange (ETDEWEB)

    DURR, HERMANN; Wang, X.J., ed.

    2016-04-28

    X-rays and electrons are two of the most fundamental probes of matter. When the Linac Coherent Light Source (LCLS), the world’s first x-ray free electron laser, began operation in 2009, it transformed ultrafast science with the ability to generate laser-like x-ray pulses from the manipulation of relativistic electron beams. This document describes a similar future transformation. In Transmission Electron Microscopy, ultrafast relativistic (MeV energy) electron pulses can achieve unsurpassed spatial and temporal resolution. Ultrafast temporal resolution will be the next frontier in electron microscopy and can ideally complement ultrafast x-ray science done with free electron lasers. This document describes the Grand Challenge science opportunities in chemistry, material science, physics and biology that arise from an MeV ultrafast electron diffraction & microscopy facility, especially when coupled with linac-based intense THz and X-ray pump capabilities.

  1. Evaluation of the effect of tooth and dental restoration material on electron dose distribution and production of photon contamination in electron beam radiotherapy.

    Science.gov (United States)

    Bahreyni Toossi, Mohammad Taghi; Ghorbani, Mahdi; Akbari, Fatemeh; Mehrpouyan, Mohammad; Sobhkhiz Sabet, Leila

    2016-03-01

    The aim of this study is to evaluate the effect of tooth and dental restoration materials on electron dose distribution and photon contamination production in electron beams of a medical linac. This evaluation was performed on 8, 12 and 14 MeV electron beams of a Siemens Primus linac. MCNPX Monte Carlo code was utilized and a 10 × 10 cm(2) applicator was simulated in the cases of tooth and combinations of tooth and Ceramco C3 ceramic veneer, tooth and Eclipse alloy and tooth and amalgam restoration materials in a soft tissue phantom. The relative electron and photon contamination doses were calculated for these materials. The presence of tooth and dental restoration material changed the electron dose distribution and photon contamination in phantom, depending on the type of the restoration material and electron beam's energy. The maximum relative electron dose was 1.07 in the presence of tooth including amalgam for 14 MeV electron beam. When 100.00 cGy was prescribed for the reference point, the maximum absolute electron dose was 105.10 cGy in the presence of amalgam for 12 MeV electron beam and the maximum absolute photon contamination dose was 376.67 μGy for tooth in 14 MeV electron beam. The change in electron dose distribution should be considered in treatment planning, when teeth are irradiated in electron beam radiotherapy. If treatment planning can be performed in such a way that the teeth are excluded from primary irradiation, the potential errors in dose delivery to the tumour and normal tissues can be avoided.

  2. The 50 MeV Beam Test Facility at LBL

    International Nuclear Information System (INIS)

    Leemans, W.; Behrsing, G.; Kim, K.J.; Krupnick, J.; Matuk, C.; Selph, F.; Chattopadhyay, S.

    1993-05-01

    A new beam line, expected to be built by September 1993, will transport the 50 MeV electron beam from the ALS LINAC into an experimental area to support various R ampersand D activities in the Center for Beam Physics at LBL. A variety of experiments are planned involving the interaction of such a relativistic electron beam with plasmas (plasma focusing), laser beams (generation of femtosecond X-ray pulses) and electromagnetic cavities (Crab cavities etc....). The beam line is designed using the measured emittance and Twiss parameters of the ALS linac. It accommodates the different requirements of the various experiments on the electron beam properties (charge, energy, pulse length) and on the handling of the beam before and after the interaction point. Special attention has also been given to incorporate diagnostics for measuring the beam properties (such as the electron energy, bunch length and charge) needed in the interpretation of the experiments

  3. Comparison of biological and genomic characteristics between a newly isolated mink enteritis parvovirus MEV-LHV and an attenuated strain MEV-L.

    Science.gov (United States)

    Mao, Yaping; Wang, Jigui; Hou, Qiang; Xi, Ji; Zhang, Xiaomei; Bian, Dawei; Yu, Yongle; Wang, Xi; Liu, Weiquan

    2016-06-01

    A virus isolated from mink showing clinical signs of enteritis was identified as a high virulent mink enteritis parvovirus (MEV) based on its biological characteristics in vivo and in vitro. Mink, challenged with this strain named MEV-LHV, exhibited severe pathological lesions as compared to those challenged with attenuated strain MEV-L. MEV-LHV also showed higher infection and replication efficiencies in vitro than MEV-L. Sequence of the complete genome of MEV-LHV was determined and analyzed in comparison with those in GenBank, which revealed that MEV-LHV shared high homology with virulent strain MEV SD12/01, whereas MEV-L was closely related to Abashiri and vaccine strain MEVB, and belonged to a different branch of the phylogenetic tree. The genomes of the two strains differed by insertions and deletions in their palindromic termini and specific unique mutations (especially VP2 300) in coding sequences which may be involved in viral replication and pathogenicity. The results of this study provide a better understanding of the biological and genomic characteristics of MEV and identify certain regions and sites that may be involved in viral replication and pathogenicity.

  4. Neutron interrogation of actinides with a 17 MeV electron accelerator and first results from photon and neutron interrogation non-simultaneous measurements combination

    Energy Technology Data Exchange (ETDEWEB)

    Sari, A., E-mail: adrien.sari@cea.fr [CEA, LIST, Laboratoire Capteurs et Architectures Electroniques, 91191 Gif-sur-Yvette Cedex (France); Carrel, F.; Lainé, F. [CEA, LIST, Laboratoire Capteurs et Architectures Electroniques, 91191 Gif-sur-Yvette Cedex (France); Lyoussi, A. [CEA, DEN, 13108 Saint-Paul-Lez-Durance Cedex (France)

    2013-10-01

    In this article, we demonstrate the feasibility of neutron interrogation using the conversion target of a 17 MeV linear electron accelerator as a neutron generator. Signals from prompt neutrons, delayed neutrons, and delayed gamma-rays, emitted by both uranium and plutonium samples were analyzed. First results from photon and neutron interrogation non-simultaneous measurements combination are also reported in this paper. Feasibility of this technique is shown in the frame of the measurement of uranium enrichment. The latter was carried out by combining detection of prompt neutrons from thermal fission and delayed neutrons from photofission, and by combining delayed gamma-rays from thermal fission and delayed gamma-rays from photofission.

  5. Mechanical design of a RF electron gun

    International Nuclear Information System (INIS)

    Woodle, M.H.; Batchelor, K.; Sheehan, J.

    1989-01-01

    Brookhaven National Laboratory is building an Accelerator Test Facility at which we plan to study laser acceleration of electrons, inverse free electron lasers and the production of X-rays by non-linear Compton scattering. The facility contains an electron gun, linac, lasers and ancillary systems which will enable the production of 6 ps duration pulses of 50-100 MeV electrons. The electron source is an one and one half cell RF Electron gun which utilizes either a thermionic or photoemissive cathode to produce 5 MeV electrons. This paper discusses how gun mechanical design considerations such as material, vacuum maintenance, surface finish, fabrication methods, cavity tuning, and cathode replacement were reconciled to arrive at the final design. 9 refs., 2 figs., 2 tabs

  6. Mechanical design of a rf electron gun

    International Nuclear Information System (INIS)

    Woodle, M.H.; Batchelor, K.; Sheehan, J.

    1988-01-01

    Brookhaven National Laboratory is building an Accelerator Test Facility at which we plan to study laser acceleration of electrons inverse free electron lasers and the production of X-rays by non- linear Compton scattering. The facility contains an electron gun, linac, lasers and ancillary systems which will enable the production of 6 ps duration pulses of 50--100 MeV electrons. The electron source is an one and one half cell RF Electron gun which utilizes either a thermionic or photoemissive cathode to produce 5 MeV electrons. This paper discusses how gun mechanical design considerations such as material, vacuum maintenance, surface finish, fabrication methods, cavity tuning, and cathode replacement were reconciled to arrive at the final design. 9 refs., 2 figs., 2 tabs

  7. Electron fluence correction factors for various materials in clinical electron beams

    International Nuclear Information System (INIS)

    Olivares, M.; Blois, F. de; Podgorsak, E.B.; Seuntjens, J.P.

    2001-01-01

    Relative to solid water, electron fluence correction factors at the depth of dose maximum in bone, lung, aluminum, and copper for nominal electron beam energies of 9 MeV and 15 MeV of the Clinac 18 accelerator have been determined experimentally and by Monte Carlo calculation. Thermoluminescent dosimeters were used to measure depth doses in these materials. The measured relative dose at d max in the various materials versus that of solid water, when irradiated with the same number of monitor units, has been used to calculate the ratio of electron fluence for the various materials to that of solid water. The beams of the Clinac 18 were fully characterized using the EGS4/BEAM system. EGSnrc with the relativistic spin option turned on was used to optimize the primary electron energy at the exit window, and to calculate depth doses in the five phantom materials using the optimized phase-space data. Normalizing all depth doses to the dose maximum in solid water stopping power ratio corrected, measured depth doses and calculated depth doses differ by less than ±1% at the depth of dose maximum and by less than 4% elsewhere. Monte Carlo calculated ratios of doses in each material to dose in LiF were used to convert the TLD measurements at the dose maximum into dose at the center of the TLD in the phantom material. Fluence perturbation correction factors for a LiF TLD at the depth of dose maximum deduced from these calculations amount to less than 1% for 0.15 mm thick TLDs in low Z materials and are between 1% and 3% for TLDs in Al and Cu phantoms. Electron fluence ratios of the studied materials relative to solid water vary between 0.83±0.01 and 1.55±0.02 for materials varying in density from 0.27 g/cm3 (lung) to 8.96 g/cm3 (Cu). The difference in electron fluence ratios derived from measurements and calculations ranges from -1.6% to +0.2% at 9 MeV and from -1.9% to +0.2% at 15 MeV and is not significant at the 1σ level. Excluding the data for Cu, electron fluence

  8. Heliospheric MeV energization due to resonant interaction

    International Nuclear Information System (INIS)

    Roth, Ilan

    2001-01-01

    The prompt enhancement of relativistic electron flux during active geomagnetic periods, and the impulsive increase in the flux of the heliospheric energetic heavy ions during active solar periods are of major importance with respect to the proper operation of electronics on space-borne spacecraft and the safety of interplanetary human travel, respectively. Both enhancements may be caused by resonant wave-particle interaction with oblique electromagnetic waves on the terrestrial and coronal field lines. Whistler waves, which are enhanced significantly during substorms and which propagate obliquely to the magnetic field, can interact with energetic electrons through Landau, cyclotron, and higher harmonic resonant interactions when the Doppler-shifted wave frequency equals any (positive or negative) integer multiple of the local relativistic gyrofrequency. This interaction occurs over a broad spatial region when a relativistic electron is bouncing in the terrestrial magnetic field. Coronal ions interact selectively with electromagnetic ion-cyclotron (emic) waves which are correlated with impulsive flares. This interaction occurs over a small spatial region when the Doppler-shifted frequency matches the first or higher harmonic of the ion gyrofrequency. Recent new observations of terrestrial MeV X-rays are interpreted as a resonant loss of the radiation belt electrons

  9. New source of MeV negative ion and neutral atom beams

    International Nuclear Information System (INIS)

    Ter-Avetisyan, S.; Braenzel, J.; Schnürer, M.; Prasad, R.; Borghesi, M.; Jequier, S.; Tikhonchuk, V.

    2016-01-01

    The scenario of “electron-capture and -loss” was recently proposed for the formation of negative ion and neutral atom beams with MeV kinetic energies. However, it does not explain why the formation of negative ions in a liquid spray is much more efficient than with an isolated atom. The role of atomic excited states in the charge-exchange processes is considered, and it is shown that it cannot account for the observed phenomena. The processes are more complex than the single electron-capture and -loss approach. It is suggested that the shell effects in the electronic structure of the projectile ion and/or target atoms may influence the capture/loss probabilities

  10. New source of MeV negative ion and neutral atom beams

    Energy Technology Data Exchange (ETDEWEB)

    Ter-Avetisyan, S., E-mail: sargis@gist.ac.kr [Center for Relativistic Laser Science, Institute for Basic Science (IBS), Gwangju 500-712 (Korea, Republic of); Department of Physics and Photon Science, GIST, Gwangju 500-712 (Korea, Republic of); Braenzel, J.; Schnürer, M. [Max Born Institute for Nonlinear Optics and Short Pulse Spectroscopy, Berlin 12489 (Germany); Prasad, R. [Institute for Laser and Plasma Physics, Heinrich Heine University, Duesseldorf 40225 (Germany); Borghesi, M. [School of Mathematics and Physics, The Queen’s University of Belfast, Belfast BT7-1NN (United Kingdom); Jequier, S.; Tikhonchuk, V. [Centre Lasers Intenses et Applications, CEA, CNRS, University of Bordeaux, 33405 Talence (France)

    2016-02-15

    The scenario of “electron-capture and -loss” was recently proposed for the formation of negative ion and neutral atom beams with MeV kinetic energies. However, it does not explain why the formation of negative ions in a liquid spray is much more efficient than with an isolated atom. The role of atomic excited states in the charge-exchange processes is considered, and it is shown that it cannot account for the observed phenomena. The processes are more complex than the single electron-capture and -loss approach. It is suggested that the shell effects in the electronic structure of the projectile ion and/or target atoms may influence the capture/loss probabilities.

  11. Measurement of the neutron-induced fission cross section of 232Th relative to 235U from 0.7 to 30 MeV

    International Nuclear Information System (INIS)

    Behzens, T.W.; Ables, E.; Browne, T.C.

    1982-01-01

    The authors have measured the fission cross-section ratio 232 Th: 235 U as a function of neutron energy from 0.7 to 30 MeV using ionization fission chambers, the threshold cross-section method, and the time-of-flight technique at the Lawrence Livermore National Laboratory 100-MeV electron linear accelerator. The measured cross-section ratio, averaged over the neutron energy interval from 1.75 to 4.00 MeV, was 0.1086 + 0.0024

  12. Dedicated Tool for Irradiation and Electrical Measurement of Large Surface Samples on the Beamline of a 2.5 Mev Pelletron Electron Accelerator: Application to Solar Cells

    OpenAIRE

    Lefèvre Jérémie; Le Houedec Patrice; Losco Jérôme; Cavani Olivier; Boizot Bruno

    2017-01-01

    We designed a tool allowing irradiation of large samples over a surface of A5 size dimension by means of a 2.5 MeV Pelletron electron accelerator. in situ electrical measurements (I-V, conductivity, etc.) can also be performed, in the dark or under illumination, to study radiation effects in materials. Irradiations and electrical measurements are achievable over a temperature range from 100 K to 300 K. The setup was initially developed to test real-size triple junction solar cells at low t...

  13. Survey on neutron production by electron beam from high power CW electron linear accelerator

    International Nuclear Information System (INIS)

    Toyama, S.

    1999-04-01

    In Japan Nuclear Cycle Development Institute, the development of high current CW electron linear accelerator is in progress. It is possible for an accelerator to produce neutrons by means of a spallation and photo nuclear reactions. Application of neutron beam produced by bremsstrahlung is one of ways of the utilization for high current electron accelerator. It is actual that many electron linear accelerators which maximum energy is higher than a few hundreds MeV are used as neutron sources. In this report, an estimate of neutron production is evaluated for high current CW electron linear accelerator. The estimate is carried out by 10 MeV beam which is maximum energy limited from the regulation and rather low for neutron production. Therefore, the estimate is also done by 17 and 35 MeV beam which is possible to be accelerated. Beryllium is considered as a target for lower electron energy in addition to Lead target for higher energy, because Beryllium has low threshold energy for neutron production. The evaluation is carried out in account of the target thickness optimized by the radiation length and neutron cross section reducing the energy loss for both of electron and neutron, so as to get the maximum number of neutrons. The result of the calculations shows neutron numbers 1.9 x 10 10 , 6.1 x 10 13 and 4.8 x 10 13 (n/s), respectively, for 10, 17, and 35 MeV with low duty. The thermal removal from the target is one of critical points. The additional shielding and cooling system is necessary in order to endure radiation. A comparison with other facilities are also carried out. The estimate of neutron numbers suggests the possibility to be applied for neutron radiography and measurement of nuclear data by means of Lead spectrometer, for example. (author)

  14. Measured neutron carbon kerma factors from 14.1 MeV to 18 MeV

    International Nuclear Information System (INIS)

    Deluca, P.M. Jr.; Barschall, H.H.; Haight, R.C.; McDonald, J.C.

    1984-01-01

    For A-150 tissue-equivalent plastic, the total neutron kerma is dominated by the hydrogen kerma. Tissue kerma is inferred with reasonable accuracy by normalization to the kerma factor ratio between tissue and A-150 plastic. Because of the close match in the hydrogen abundance in these materials, the principal uncertainty is due to the kerma factors of carbon and oxygen. We have measured carbon kerma factor values of 0.183 +- 0.015 10 -8 cGy cm 2 and 0.210 +- 0.16 10 -8 cGy cm 2 at 14.1-MeV and 15-MeV neutron energy, respectively. A preliminary value of 0.297 +- 0.03 10 -8 cGy cm 2 has been determined at 17.9 MeV. A recent microscopic cross section measurement of the (n,n'3α) reaction in carbon at 14.1-MeV energy gives a kerma factor of 0.184 +- 0.019 10 8 cGy cm 2 in agreement with the present result. 9 refs., 4 figs., 2 tabs

  15. Formation of 1.4 MeV runaway electron flows in air using a solid-state generator with 10 MV/ns voltage rise rate

    Science.gov (United States)

    Mesyats, G. A.; Pedos, M. S.; Rukin, S. N.; Rostov, V. V.; Romanchenko, I. V.; Sadykova, A. G.; Sharypov, K. A.; Shpak, V. G.; Shunailov, S. A.; Ul'masculov, M. R.; Yalandin, M. I.

    2018-04-01

    Fulfillment of the condition that the voltage rise time across an air gap is comparable with the time of electron acceleration from a cathode to an anode allows a flow of runaway electrons (REs) to be formed with relativistic energies approaching that determined by the amplitude of the voltage pulse. In the experiment described here, an RE energy of 1.4 MeV was observed by applying a negative travelling voltage pulse of 860-kV with a maximum rise rate of 10 MV/ns and a rise time of 100-ps. The voltage pulse amplitude was doubled at the cathode of the 2-cm-long air gap due to the delay of conventional pulsed breakdown. The above-mentioned record-breaking voltage pulse of ˜120 ps duration with a peak power of 15 GW was produced by an all-solid-state pulsed power source utilising pulse compression/sharpening in a multistage gyromagnetic nonlinear transmission line.

  16. Temporal properties of coherent synchrotron radiation produced by an electron bunch moving along an arc of a circle

    International Nuclear Information System (INIS)

    Geloni, G.; Saldin, E.L.; Schneidmiller, E.A.; Yurkov, M.V.

    2004-01-01

    In the limit for a large distance between bunch and detector and under the assumption that the entire process, i.e. radiation and detection, happens in vacuum, one can use the well-known Schwinger formulas in order to describe the single-particle radiation in the case of circular motion. Nevertheless, these formulas cannot be applied for particles moving in an arc of a circle. In this paper, we present a characterization of coherent synchrotron radiation (CSR) pulses in the time-domain as they are emitted by an electron bunch moving in an arc of a circle. This can be used in order to give a quantitative estimation of the effects of a finite bending magnet extension on the characteristics of the CSR pulse

  17. Tooth enamel dosimetric response to 2.8 MeV neutrons

    Science.gov (United States)

    Fattibene, P.; Angelone, M.; Pillon, M.; De Coste, V.

    2003-03-01

    Tooth enamel dosimetry, based on electron paramagnetic resonance (EPR) spectroscopy, is recognized as a powerful method for individual retrospective dose assessment. The method is mainly used for individual dose reconstruction in the epidemiological studies aimed at the radiation risk analysis. The study of the sensitivity of tooth enamel as a function of radiation quality is one of the main goals of the research in this field. In the present work, tooth enamel dose response in a monoenergetic neutron flux of 2.8 MeV, generated by the D-D reaction, was studied for in air and in phantom irradiations of enamel samples and of whole teeth. EPR measurements were complemented by Monte Carlo calculation and by gamma dose discrimination obtained with thermoluminescent and Geiger-Muller tube measurements. The 2.8 MeV neutrons to 60Co relative sensitivity was 0.33±0.08.

  18. Tooth enamel dosimetric response to 2.8 MeV neutrons

    International Nuclear Information System (INIS)

    Fattibene, P.; Angelone, M.; Pillon, M.; De Coste, V.

    2003-01-01

    Tooth enamel dosimetry, based on electron paramagnetic resonance (EPR) spectroscopy, is recognized as a powerful method for individual retrospective dose assessment. The method is mainly used for individual dose reconstruction in the epidemiological studies aimed at the radiation risk analysis. The study of the sensitivity of tooth enamel as a function of radiation quality is one of the main goals of the research in this field. In the present work, tooth enamel dose response in a monoenergetic neutron flux of 2.8 MeV, generated by the D-D reaction, was studied for in air and in phantom irradiations of enamel samples and of whole teeth. EPR measurements were complemented by Monte Carlo calculation and by gamma dose discrimination obtained with thermoluminescent and Geiger-Muller tube measurements. The 2.8 MeV neutrons to 60 Co relative sensitivity was 0.33±0.08

  19. 238U photonuclear studies with 5-10 MeV photons

    International Nuclear Information System (INIS)

    Hawkes, N.P.

    1986-02-01

    The 238 U photofission and photoneutron cross sections, and the mean number -ν of prompt neutrons per fission, have been measured between 5 and 10 MeV. The experiment was carried out using bremsstrahlung from the electron linear accelerator HELIOS at Harwell. Neutrons from (γ,f) and (γ,n) reactions on 238 U were detected, and neutron multiplicity distributions recorded. Photoneutron events were separated from photofission events by means of their different multiplicities. (author)

  20. Electronic sputtering

    International Nuclear Information System (INIS)

    Johnson, R.E.

    1989-01-01

    Electronic sputtering covers a range of phenomena from electron and photon stimulated desorption from multilayers to fast heavy ion-induced desorption (sputtering) of biomolecules. In this talk the author attempted. Therefore, to connect the detailed studies of argon ejection from solid argon by MeV ions and keV electrons to the sputtering of low temperatures molecular ices by MeV ions then to biomolecule ejection from organic solids. These are related via changing (dE/dx) e , molecular size, and transport processes occurring in materials. In this regard three distinct regions of (dE/dx) e have been identified. Since the talk this picture has been made explicit using a simple spike model for individual impulsive events in which spike interactions are combined linearly. Since that time also the molecular dynamics programs (at Virginia and Uppsala) have quantified both single atom and dimer processes in solid Ar and the momentum transport in large biomolecule sputtering. 5 refs

  1. Observation of high energy electrons and protons in the South Atlantic geomagnetic anomaly by Ohzora Satellite

    International Nuclear Information System (INIS)

    Nagata, K.; Murakami, H.; Nakamoto, A.; Hasebe, N.; Kikuche, J.; Doke, T.

    1988-01-01

    Observed results of the high energy electrons (0.19 - 3.2 MeV) and protons (0.58 - 35 MeV) of the South Atlantic Geomagnetic Anomaly are presented. Two silicon Δ E-E telescopes on the ohzora satellite (EXOS-C, 1984-15A) were used to observe the high energy particle and the maximum intensity of electrons and protons. The powers of energy spectra above 1 MeV have different values from energy region below 1 MeV. The electron and proton intensities are greatest at pitch angle maximized at 90 0 . (author) [pt

  2. The S-DALINAC polarized electron injector SPIN

    Energy Technology Data Exchange (ETDEWEB)

    Eckardt, Christian; Bahlo, Thore; Bangert, Phillip; Barday, Roman; Bonnes, Uwe; Brunken, Marco; Burandt, Christoph; Eichhorn, Ralf; Enders, Joachim; Espig, Martin; Platz, Markus; Poltoratska, Yuliya; Roth, Markus; Schneider, Fabian; Wagner, Markus; Weber, Antje; Zwicker, Benjamin [Institut fuer Kernphysik, Technische Universitaet, Darmstadt (Germany); Ackermann, Wolfgang; Mueller, Wolfgang F.O.; Weiland, Thomas [Institut fuer Theorie Elektromagnetischer Felder, Technische Universitaet, Darmstadt (Germany); Aulenbacher, Kurt [Institut fuer Kernphysik, Johannes Gutenberg-Universitaet, Mainz (Germany)

    2011-07-01

    A source of polarized electrons has been installed at the superconducting 130 MeV Darmstadt electron linac S-DALINAC. Polarized electrons are generated by irradiating a GaAs cathode with pulsed Ti:Sapphire and diode lasers and preaccelerated to 100 keV. A Wien filter and 100 keV Mott polarimeter are used for spin manipulation and polarization measurement and various beam diagnostic elements are installed. To measure the beam polarization downstream of the superconducting injector linac a 5-10 MeV Mott polarimeter and a Compton-transmission polarimeter have been developed. We report on the status of the polarized electron source and foreseen experiments.

  3. Excitation function for the population of the 4.51 MeV state of 27Al inelastic proton scattering. Evidence for 6- strength?

    International Nuclear Information System (INIS)

    Spicer, B.M.; Koutsoliotas, S.

    1995-01-01

    The excitation function for emission of 2.30 MeV gamma rays from the 4.51 MeV state of 27 Al formed in inelastic proton scattering has been measured for proton energies from 5.6 to 7.3 MeV. A resonance previously seen in both inelastic electron and proton scattering from 28 Si at 17.35 MeV has been observed as a resonance in the excitation function, as well as seven other resonances, all of which are narrow (i.e., less than 100 keV wide). It is suggested that these may represent fragments of 6 - strength in 28 Si. 6 refs., 1 tab., 2 figs

  4. Evaluation of the effect of tooth and dental restoration material on electron dose distribution and production of photon contamination in electron beam radiotherapy

    International Nuclear Information System (INIS)

    Bahreyni Toossi, M.T.; Ghorbani, Mahdi; Akbari, Fatemah; Sabet, Leila S.; Mehrpouyan, Mohammad

    2016-01-01

    The aim of this study is to evaluate the effect of tooth and dental restoration materials on electron dose distribution and photon contamination production in electron beams of a medical linac. This evaluation was performed on 8, 12 and 14 MeV electron beams of a Siemens Primus linac. MCNPX Monte Carlo code was utilized and a 10 × 10 cm 2 applicator was simulated in the cases of tooth and combinations of tooth and Ceramco C3 ceramic veneer, tooth and Eclipse alloy and tooth and amalgam restoration materials in a soft tissue phantom. The relative electron and photon contamination doses were calculated for these materials. The presence of tooth and dental restoration material changed the electron dose distribution and photon contamination in phantom, depending on the type of the restoration material and electron beam’s energy. The maximum relative electron dose was 1.07 in the presence of tooth including amalgam for 14 MeV electron beam. When 100.00 cGy was prescribed for the reference point, the maximum absolute electron dose was 105.10 cGy in the presence of amalgam for 12 MeV electron beam and the maximum absolute photon contamination dose was 376.67 μGy for tooth in 14 MeV electron beam. The change in electron dose distribution should be considered in treatment planning, when teeth are irradiated in electron beam radiotherapy. If treatment planning can be performed in such a way that the teeth are excluded from primary irradiation, the potential errors in dose delivery to the tumour and normal tissues can be avoided.

  5. Cross sections and analyzing powers of 15N(p,n)15O at 200 MeV and 494 MeV

    International Nuclear Information System (INIS)

    Ciskowski, D.E.

    1989-11-01

    Differential cross sections and analyzing powers have been measured for the 15 N(p,n) 15 O(g.s.) reaction at bombarding energies of 200 MeV and 494 MeV. The 494 MeV data were obtained at the LAMPF Neutron Time-Of-Flight Facility on an 82 m flight path with a resolution of about 2.7 MeV. The 200 MeV data were obtained at IUCF on a 76m flight path with a resolution of about 1.1 MeV. At both energies, the measured analyzing power is small, the magnitude is less than .2 for momentum transfers of less than 1 fm -1 . In contrast, both Relativistic and standard DWIA calculations predict a maximum of A=-.7 near q=0.7 fm -1 . 53 refs., 44 figs

  6. Remarks about a ''parasitic'' 200 MeV electron ring

    International Nuclear Information System (INIS)

    Carlos, P.

    1982-10-01

    The principle of such facility is extremely simple, and consists merely of a set of very thin movable tungsten wires (40 μm < phi < 100 μm) which can be adjusted to intercept a small part of the main linac beam at the center of the BE deflection magnet. Incident electrons are thus scattered in all directions and in particular in the direction of the BE beam transport system, which can be attuned to the average energy of the scattered electrons to send a ''parasitic '' electron beam in the BE experimental area. This parasitic electron beam facility is currently used to operate the low energy tagged photon facility. In order to obtain an intense monochromatic tagged photon beam with a 100% duty cycle a simple procedure is used. It consists of feeding a small stretcher ring equipped with an internal gas jet target with a single electron pulse of width δt delivered every T seconds

  7. Electron-electron bound states in Maxwell-Chern-Simons-Proca QED3

    International Nuclear Information System (INIS)

    Belich, H.; Helayel-Neto, J.A.; Ferreira, M.M. Jr.; Maranhao Univ., Sao Luis, MA

    2002-10-01

    We start from a parity-breaking MCS QED 3 model with spontaneous breaking of the gauge symmetry as a framework for evaluation of the electron-electron interaction potential and for attainment of numerical values for the e - e - - bound state. Three expressions V eff↓↓ , V eff↓↑ , V eff↓↓ ) are obtained according to the polarization state of the scattered electrons. In an energy scale compatible with condensed matter electronic excitations, these potentials become degenerated. The resulting potential is implemented in the Schroedinger equation and the variational method is applied to carry out the electronic binding energy. The resulting binding energies in the scale of 10-100 meV and a correlation length in the scale of 10 - 30 Angstrom are possible indications that the MCS-QED 3 model adopted may be suitable to address an eventual case of e - e - pairing in the presence of parity-symmetry breakdown. The data analyzed here suggest an energy scale of 10-100 meV to fix the breaking of the U(1)-symmetry. (author)

  8. Tests of an electron monitor for routine quality control measurements of electron energies

    International Nuclear Information System (INIS)

    Ramsay, E.B.; Reinstein, L.E.; Meek, A.G.

    1991-01-01

    The depth dose for electrons is sensitive to energy and the AAPM Task Group 24 has recommended that tests be performed at monthly intervals to assure electron beam energy constancy by verifying the depth for the 80% dose to within ±3 mm. Typically, this is accomplished by using a two-depth dose ratio technique. Recently, a new device, the Geske monitor, has been introduced that is designed for verifying energy constancy in a single reading. The monitor consists of nine parallel plate detectors that alternate with 5-mm-thick absorbers made of an aluminum alloy. An evaluation of the clinical usefulness of this monitor for the electron beams available on a Varian Clinac 20 has been undertaken with respect to energy discrimination. Beam energy changes of 3 mm of the 80% dose give rise to measurable output changes ranging from 1.7% for 20-MeV electron beams to 15% for 6-MeV electron beams

  9. Growth rate of dislocation loop in Fe-Ni-Cr alloy under Kr+ ion and electron irradiation

    International Nuclear Information System (INIS)

    Kimoto, T.; Allen, C.W.; Rehn, L.E.

    1991-10-01

    In order to examine the effect of irradiating particle species on the growth rate of radiation-induced dislocation loops, a solution-annealed Fe-25Ni-15Cr-0.02C alloy was irradiated at 723 K first by 1.5 MeV Kr + ions for 2520 sec, then by 1.5 MeV Kr + ions and 1.0 MeV electrons simultaneously for 780 sec, and finally by 1.0 MeV electrons for 780 sec with the HVEM-Tandem Facility in Argonne National Laboratory. The calculated damage rate by 1.5 MeV Kr + ions was 5.8 x 10 -4 dpa/s, and that by 1.0 MeV electrons was 1 x 10 -4 dpa/s. The growth rate of a dislocation loop located at the center of the specimen was 7 x 10 -3 nm/s for the Kr + ion irradiation, 4 x 10 -2 nm/s for the simultaneous Kr + and electron irradiation, and (2--3) x 10 -2 nm/s for the electron irradiation. This implies that the electron irradiation is about 19 times more effective in the growth of radiation-induced dislocation loops than the Kr + ion irradiation. The dislocation loop growth rate under the simultaneous Kr + and electron irradiation is higher than the sum of the growth rates under the individual Kr + and electron irradiations. 5 refs., 4 figs

  10. Experimental studies to the dose distribution from pendulum irradiation of the middle part of the ESOPHAGUS with electrons and X-rays from a 42 MeV betatron

    International Nuclear Information System (INIS)

    Bark, R.

    1973-01-01

    Experimental studies of the dose distributions in the area of the middle esophagus resulting from pendulum irradiation with electrons and X-rays are reported. In these studies the energy and the arrangement of the pendulum angle were to be varied so as to generate the maximum possible dose decrease from the focal area to the healthy tissue. The electron energies used were 30 and 42 MeV, the energies of ultrahard X-rays were 42 MV. All studies carried out with the different pendulum angles indicated that electron therapy is in no way capable of meeting the existing requirements in terms of low exposures of the lung, bone marrow and skin. However, the use of ultrahard X-rays offers much better dose distribution conditions. These can be achieved only by bi-segmental pendulum irradiation under a bilateral angle of 70 0 (30 0 dorsal, 40 0 ventral). (orig./RF) [de

  11. High energy electron acceleration with PW-class laser system

    International Nuclear Information System (INIS)

    Nakanii, N.; Kondo, K.; Yabuuchi, T.; Tsuji, K.; Kimura, K.; Fukumochi, S.; Kashihara, M.; Tanimoto, T.; Nakamura, H.; Ishikura, T.; Kodama, R.; Mima, K.; Tanaka, K. A.; Mori, Y.; Miura, E.; Suzuki, S.; Asaka, T.; Yanagida, K.; Hanaki, H.; Kobayashi, T.

    2008-01-01

    We performed electron acceleration experiment with PW-class laser and a plasma tube, which was created by imploding a hollow polystyrene cylinder. In this experiment, electron energies in excess of 600 MeV have been observed. Moreover, the spectra of a comparatively high-density plasma ∼10 19 cm -3 had a bump around 10 MeV. Additionally, we performed the absolute sensitivity calibration of imaging plate for 1 GeV electrons from the injector Linac of Spring-8 in order to evaluate absolute number of GeV-class electrons in the laser acceleration experiment

  12. Chiral recognition in electron scattering by S- and R-2-butanol

    DEFF Research Database (Denmark)

    Jones, Nykola C.; Hoffmann, Søren Vrønning; Field, David

    2015-01-01

    Experiments are described involving the low energy scattering of electrons from the two optical enantiomers S- and R- 2-butanol. Using a synchrotron radiation photoionization source on the ASTRID storage ring, scattering spectra are reported between a few meV and 140 meV at an electron energy...

  13. SOR-RING: an electron storage ring dedicated to spectroscopy, 2

    International Nuclear Information System (INIS)

    Kitamura, H.; Miyahara, T.; Sato, S.; Watanabe, M.; Mitani, S.

    1976-01-01

    A 300 MeV electron storage ring to be used exclusively as a synchrotron radiation source for spectroscopy has been constructed in Institute for Nuclear Study (INS), University of Tokyo, Tanashi. Its useful spectral range lies between 40 and 2200 A. The 1.3 GeV electron synchrotron of INS currently being operated for high energy particle experiments serves as an injector. Electron beams are extracted from the synchrotron at 300 MeV, transported about twenty meters, and injected to the ring one pulse per second. In the test operation a current of 10 mA was stored with a lifetime of one hour, while the design goal determined by the Touschek effect is 100 mA with one hour, for operation in 300 MeV. Increase of operating energy up to 375 MeV is feasible with a minor modification of the present design. (auth.)

  14. Three-fold increase of M1 strength in 40Ar at 10 MeV excitation energy

    Science.gov (United States)

    Tornow, Werner; Finch, Sean; Krishichayan, Fnu; Tonchev, Anton

    2017-09-01

    We reexamined the excitation energy region of 40Ar around 9.8 MeV with the goal of determining the known M1 strength located at 9.76 MeV more accurately. The physics motivation was based on the fact that i) the neutrino-nucleus interaction cross section is proportional to the M1 strength of a nucleus, ii) DUNE, the Deep Underground Neutrino Experiment at SURF will be using liquid argon as detector medium, iii) the energy spectrum of supernova neutrinos is peaked at approximately 10 MeV. Mono-energetic and linearly polarized photons of 9.88 MeV were produced via Compton backscattering of 548 nm FEL photons from 543 MeV electrons at the High-Intensity γ-ray Source (HI γS) facility at TUNL. The 1.25 cm diameter photon beam with energy spread of 300 keV (FWHM) interacted with argon gas contained in a high-pressure cell. The cell was viewed with HPGe detectors placed at 90o relative to the incident photon beam in the horizontal and vertical planes to distinguish between E1 and M1 de-excitation γ-rays. Our re-measurement provided an increase in M1 strength by a factor of approximately 3, mostly due to the discovery that the known level in 40Ar at 9.84 MeV is of M1 character and not of E1 character, as previously thought. In addition to the already known M1 state at 9.76 MeV, we observed weaker M1 states at 9.70, 9.81, 9.87, and 9.89 MeV.

  15. The electron accelerator Ridgetron

    International Nuclear Information System (INIS)

    Hayashizaki, N.; Hattori, T.; Odera, M.; Fujisawa, T.

    1999-01-01

    Many electron accelerators of DC or RF type have been widely used for electron beam irradiation (curing, crosslinking of polymers, sterilization of medical disposables, preservation of food, etc.). Regardless of the acceleration energy, the accelerators to be installed in industrial facilities, have to satisfy the requires of compact size, low power consumption and stable operation. The DC accelerator is realized very compact in the energy under 300 keV, however, it is large to prevent the discharge of an acceleration column in the energy over 300 keV. The RF electron accelerator Ridgetron has been developed to accelerate the continuous beam of the 0.5-10 MeV range in compact space. It is the first example as an electron accelerator incorporated a ridged RF cavity. A prototype system of final energy of 2.5 MeV has been studied to confirm the feasibility at present

  16. On the coherent radiation of an electron bunch moving in an arc of a circle

    International Nuclear Information System (INIS)

    Saldin, E.L.; Shneidmiller, E.A.; Yurkov, M.V.

    1997-01-01

    Existing theories of coherent synchrotron radiation (CSR) are related to the motion of an electron bunch on a circular orbit and do not describe the case of finite magnet length. We present the CSR theory for a bunch of any length moving in an arc of a finite angle. The radiative interaction of the electrons in the bunch is analyzed for a line charge distribution using ultrarelativistic approximation. It is shown in particular that this interaction is important not only inside the magnet but also on the straight part of the trajectory after the magnet. Detailed analytical study of the CSR effects in the electron bunch with a stepped distribution of the charge density has been performed. The simple analytical technique of the radiative force calculation has been developed. The analytical solutions in the form of elementary functions are obtained for the radiative interaction force, for the energy loss distribution along the bunch and for the total energy loss of the bunch. The latter result is confirmed with calculation of the energy of coherent radiation in far zone. The criterion for the applicability region of the preceding theories to the case of a finite magnet length is obtained

  17. Acceleration of Electrons in a Diffraction Dominated IFEL

    CERN Document Server

    Musumeci, Pietro; Pellegrini, Claudio; Ralph, J; Rosenzweig, J B; Sung, C; Tochitsky, Sergei Ya; Travish, Gil

    2004-01-01

    We report on the observation of energy gain in excess of 20 MeV at the Inverse Free Electron Laser Accelerator experiment at the Neptune Laboratory at UCLA. A 14.5 MeV electron beam is injected ina 50 cm long undulator strongly tapered both in period and field amplitude. A CO2 10 μ m laser with power >300 GW is used as the IFEL driver. The Rayleigh range of the laser (1.8cm) is shorter than the undulator length so that the interaction is diffraction dominated. Few per cent of the injected particles are trapped in stable accelerating buckets and electrons with energies up to 35 MeV are detected on the magnetic spectrometers. Experimental results on the scaling of the accelerator characteristics versus input parameters like injection energy, laser focus position and laser power are discussed. Three dimensional simulations are in good agreement with the electron energy spectrums observed in the experiment and indicate that substantial energy exchange between laser and electron beam only occurs in the firs...

  18. 14 MeV neutrons physics and applications

    CERN Document Server

    Valkovic, Vladivoj

    2015-01-01

    Despite the often difficult and time-consuming effort of performing experiments with fast (14 MeV) neutrons, these neutrons can offer special insight into nucleus and other materials because of the absence of charge. 14 MeV Neutrons: Physics and Applications explores fast neutrons in basic science and applications to problems in medicine, the environment, and security.Drawing on his more than 50 years of experience working with 14 MeV neutrons, the author focuses on:Sources of 14 MeV neutrons, including laboratory size accelerators, small and sealed tube generators, well logging sealed tube ac

  19. Multiplicity of secondary electrons emitted by carbon thin targets by impact of H0, H2+ and H3+ projectiles at MeV energies

    International Nuclear Information System (INIS)

    Vidovic, Zvonimir

    1997-01-01

    This work focuses on the study of the emission statistics of secondary electrons from thin carbon foils bombarded with H 0 , H 2 + and H 3 + projectiles in the 0.25 - 2.2 MeV energy range. The phenomenon of secondary electron emission from solids under the impact of swift ions is mainly due to inelastic interactions with target electrons. Phenomenological and theoretical descriptions as well as a summary of the main theoretical models are the subjects of the first chapter. The experimental set-up used to measure event by event the electron emission of the two faces of the thin carbon foils crossed by an energetic projectile is described in the chapter two. In this chapter there are also presented the method and the algorithms used to process experimental spectra in order to obtain the statistical distribution of the emitted electrons. Chapter three presents the measurements of secondary electron emission induced by H 0 atoms passing through thin carbon foils. The secondary electron yields are studied in correlation with emergent projectile charge state. We show the peculiar role of the projectile electron, whether it remains or not bound to the incident proton. The fourth chapter is dedicated to the secondary electron emission induced by H 2 + and H 3 + polyatomic ions. The results are interpreted in terms of collective effects in the interactions of the ions with solids. The role of the proximity of the protons, molecular ions fragments, upon the amplitude of these collected effects is evidenced from the study of the statistics of forward emission. The experiments allowed us to shed light on various aspects of atom and polyatomic ion interactions with solid surfaces. (author)

  20. Secondary electron emission of thin carbon foils under the impact of hydrogen atoms, ions and molecular ions, under energies within the MeV range

    International Nuclear Information System (INIS)

    Vidovic, Z.

    1997-06-01

    This work focuses on the study of the emission statistics of secondary electrons from thin carbon foils bombarded with H 0 , H 2 + and H 3 + projectiles in the 0.25-2.2 MeV energy range. The phenomenon of secondary electron emission from solids under the impact of swift ions is mainly due to inelastic interactions with target electrons. The phenomenological and theoretical descriptions, as well as a summary of the main theoretical models are the subject of the first chapter. The experimental set-up used to measure event by event the electron emission of the two faces of a thin carbon foil traversed by an energetic projectile is described in the chapter two. In this chapter are also presented the method and algorithms used to process experimental spectra in order to obtain the statistical distribution of the emitted electrons. Chapter three presents the measurements of secondary electron emission induced by H atoms passing through thin carbon foils. The secondary electron yields are studied in correlation with the emergent projectile charge state. We show the peculiar role of the projectile electron, whether it remains or not bound to the incident proton. The fourth chapter is dedicated to the secondary electron emission induced by H 2 + and H 3 + polyatomic ions. The results are interpreted in terms of collective effects in the interactions of these ions with solids. The role of the proximity of the protons, molecular ion fragments, upon the amplitude of these collective effects is evidenced from the study of the statistics of forward emission. These experiences allowed us to shed light on various aspects of atom and polyatomic ion inter-actions with solid surfaces. (author)

  1. The effect of electron collimator leaf shape on the build-up dose in narrow electron MLC fields

    International Nuclear Information System (INIS)

    Vatanen, T; Vaeaenaenen, A; Lahtinen, T; Traneus, E

    2009-01-01

    Previously, we have found that the build-up dose from abutting narrow electron beams formed with unfocussed electron multi-leaf collimator (eMLC) steal leaves was higher than with the respective open field. To investigate more closely the effect of leaf material and shape on dose in the build-up region, straight, round (radius 1.5 cm) and leaf ends with a different front face angle of α (leaf front face pointing towards the beam axis at an angle of 90 - α) made of steel, brass and tungsten were modelled using the BEAMnrc code. Based on a treatment head simulation of a Varian 2100 C/D linac, depth-dose curves and profiles in water were calculated for narrow 6, 12 and 20 MeV eMLC beams (width 1.0 cm, length 10 cm) at source-to-surface distances (SSD) of 102 and 105 cm. The effects of leaf material and front face angle were evaluated based on electron fluence, angle and energy spectra. With a leaf front face angle of 15 deg., the dose in the build-up region of the 6 MeV field varied between 91 and 100%, while for straight and round leaf shapes the dose varied between 89 and 100%. The variation was between 94 and 100% for 12 and 20 MeV. For abutting narrow 6 MeV fields with total field size 5 x 10 cm 2 , the build-up doses at 5 mm depth for the face angle 15 deg. and straight and round leaf shapes were 96% and 86% (SSD 102 cm) and 89% and 85% (SSD 105 cm). With higher energies, the effect of eMLC leaf shape on dose at 5 mm was slight (3-4% units with 12 MeV) and marginal with 20 MeV. The fluence, energy and angle spectra for total and leaf scattered electrons were practically the same for different leaf materials with 6 MeV. With high energies, the spectra for tungsten were more peaked due to lower leaf transmission. Compared with straight leaf ends, the face angle of 15 deg. and round leaf ends led to a 1 mm (for 6 MeV) and between 1 and 5 mm (12 and 20 MeV at a SSD of 105 cm) decrease of therapeutic range and increase of the field size, respectively. However

  2. Design and construction of a novel compact doubly achromatic asymmetric 2700 magnet system for 25 MeV therapy electron accelerator

    International Nuclear Information System (INIS)

    Hutcheon, R.M.; Hodge, S.B.

    1980-09-01

    A modern cancer therapy electron accelerator unit must satisfy many design constraints, one of which is the isocentric height above floor level. Usually 130 cm is considered the maximum height at which a nurse can work with a patient. The advent of higher energy machines has increasingly made this more difficult to achieve, as higher magnetic fields are required in the magnet that directs the beam onto the patient. A new 270 degree doubly-achromatic magnet configuration has been developed which minimizes the isocentre height for a given maximum energy and maximum magnetic field. The system is an asymmetric two-magnet configuration, with zero field index, equal fields and a bend of greater than 180 degrees in the first magnet. It is compact, easy to manufacture and relatively insensitive to assembly tolerances. Energy defining slits are easily incorporated in the design and can readily be radiation shielded. Input and output beam matching and steering is easily accomplished with a compact input quadrupole doublet and small steering windings. This report details the design and bench testing of a head magnet for a 25 MeV electron accelerator with +- 10 percent energy acceptance. The output beam requirement is < 3 mm diameter with < +- 17 mrad angular divergence. (auth)

  3. The relative biological effectiveness of 60Co γ-rays, 55 kVp X-rays, 250 kVp X-rays, and 11 MeV electrons at low doses

    International Nuclear Information System (INIS)

    Spadinger, I.; Palcic, B.

    1992-01-01

    The RBE of selected low-LET radiation modalities (55 kVp X- rays, 250 kVp X-rays, 60 Co γ-rays, and 11 MeV electrons) was investigated for survival of two cell lines (V79 and CHO). Detailed measurements were made in the 0 to 3 Gy dose range using an image cytometry device to accurately determine the number of cells assayed at each dose point. Data were also collected in the high dose range (0 to 10 Gy) using conventional counting and plating techniques. RBE values (#+- #1 SE) varied from 1.0±0.07 (V79 cells) and 1.2± 0.05 (CHO cells) at high doses to 1.3±0.07 (V79) and 1.4±0.1 (CHO) at low doses for 55 kVp X-rays, from 1.1±0.05 (V79) and 1.1±0.04 (CHO) at high doses to 1.1±0.06 (V79) and 1.2±0.2 (CHO) at low doses for 250 kVp X-rays, and from 1.1±0.08 (V79) and 1.0±0.04 (CHO) at high doses to 1.0±0.06 (V79) and 0.9±0.1 (CHO) at low doses for 11 MeV electrons. Only the low and high dose RBEs for 55 kVp X-rays relative to 60 Co γ-rays were significantly different. (author)

  4. Electron cooling and recombination experiments with an adiabatically expanded electron beam

    International Nuclear Information System (INIS)

    Pastuszka, S.; Heidelberg Univ.; Schramm, U.; Heidelberg Univ.; Grieser, M.; Heidelberg Univ.; Broude, C.; Heidelberg Univ.; Grimm, R.; Heidelberg Univ.; Habs, D.; Heidelberg Univ.; Kenntner, J.; Heidelberg Univ.; Miesner, H.J.; Heidelberg Univ.; Schuessler, T.; Heidelberg Univ.; Schwalm, D.; Heidelberg Univ.; Wolf, A.; Heidelberg Univ.

    1996-01-01

    Magnetically guided electron beams with transverse temperatures reduced with respect to the cathode temperature by a factor of more than 7 were realized in the electron cooling device of the heavy-ion storage ring TSR and the effect of the reduced transverse temperature in recombination and electron cooling experiments was studied. Measured dielectronic recombination resonances at low relative energy and spectra of laser-stimulated recombination indicate that transverse electron temperatures of about 17 meV have been obtained at cathode temperatures of about 110 meV. The temperature dependence of the spontaneous electron-ion recombination rate during electron cooling was investigated and found to follow the inverse square-root law expected from the theory of radiative recombination, although the measured absolute rates are higher than predicted. A new method based on analyzing the intensity of the fluorescence light emitted during simultaneous laser and electron cooling is used to measure the longitudinal electron cooling force in a range of relative velocities extending over two orders of magnitude (10 5 -10 7 cm/s). The results confirm the occurrence of 'magnetized electron cooling' also at the reduced transverse temperature and show that, compared to earlier measurements at the high transverse temperature, the cooling force increases by about a factor of 2; a considerably larger increase by a factor of ∼5 would be expected if 'magnetized electron cooling' would not exist. (orig.)

  5. Release the beams! - Linac4 ready to hit the 50 MeV mark

    CERN Multimedia

    Katarina Anthony

    2015-01-01

    The Linac4 accelerator is now prepared to reach 50 MeV. This milestone energy - expected in the coming weeks - will allow the machine to act as a replacement for the ageing Linac2, four years before it takes over at the head of the accelerator chain in 2020.    Inside the Linac4 tunnel, the final DTL cavities will guide beams to 50 MeV.  (Image: Stephan Russenschuck.) The Linac4 accelerator will bring H- ion beams (hydrogen atoms with an extra electron) up to 160 MeV for injection into the PS Booster. As a key part of the LHC injector upgrade programme, Linac4 will allow the PS Booster to double its beam brightness, which will contribute to increasing the LHC’s luminosity. Linac4 will soon bring beams up to 50 MeV - the current energy delivered by the Linac2 accelerator. This milestone follows on from another recent accomplishment: the installation and commissioning of the final Drift Tube Linac (DTL) tank. Using an innovati...

  6. Polystyrene calorimeter for electron beam dose measurements

    DEFF Research Database (Denmark)

    Miller, A.

    1995-01-01

    Calorimeters from polystrene have been constructed for dose measurement at 4-10 MeV electron accelerators. These calorimeters have been used successfully for a few years, and polystyrene calorimeters for use at energies down to 1 MeV and being tested. Advantage of polystyrene as the absorbing...

  7. Total K-vacancy production in Ne (10 MeV) traversing Al

    International Nuclear Information System (INIS)

    Groeneveld, K.O.; Kolb, B.; Schader, J.; Sevier, K.D.

    1976-01-01

    Deexcitation of projectile inner shell vacancies created while traversing a solid foil may take place via competing processes: a) vacancy sharing with foil atoms in close impacts, b) radiative and non-radiative electron capture, and c) such X-ray and Auger electron transitions are possible in the heavy ion projectile. The change in K-vacancy creation with foil thickness can be investigated by measuring either projectile or target X-rays where the vacancies are created by Coulomb excitation and process a. In the system Ne (10 MeV) on Al, detecting Al K X-rays, the Ne K-vacancy production probability has been determined. (orig.) [de

  8. Two-stage free electron laser research

    Science.gov (United States)

    Segall, S. B.

    1984-10-01

    KMS Fusion, Inc. began studying the feasibility of two-stage free electron lasers for the Office of Naval Research in June, 1980. At that time, the two-stage FEL was only a concept that had been proposed by Luis Elias. The range of parameters over which such a laser could be successfully operated, attainable power output, and constraints on laser operation were not known. The primary reason for supporting this research at that time was that it had the potential for producing short-wavelength radiation using a relatively low voltage electron beam. One advantage of a low-voltage two-stage FEL would be that shielding requirements would be greatly reduced compared with single-stage short-wavelength FEL's. If the electron energy were kept below about 10 MeV, X-rays, generated by electrons striking the beam line wall, would not excite neutron resonance in atomic nuclei. These resonances cause the emission of neutrons with subsequent induced radioactivity. Therefore, above about 10 MeV, a meter or more of concrete shielding is required for the system, whereas below 10 MeV, a few millimeters of lead would be adequate.

  9. Experimental and calculated effectiveness of a radiochromic dye film to stopping 21 MeV 7Li and 64 MeV 16O ions

    International Nuclear Information System (INIS)

    Olsen, K.J.; Hansen, J.W.

    1984-01-01

    Relative radiation effectiveness, RE, of 21 MeV 7 Li and 64 MeV 16 O ions being completely stopped in a tissue equivalent film dose meter has been measured as a function of penetration depth and energy, and the results have been compared with calculations based on a delta-ray theory for heavy charged particles developed by Katz et al. The experiment was designed to test calculations particularly in the Bragg-peak region of the slowing down particles where significant deviation between theory and experiment was found. Fitting of the characteristic D 37 dose and the size of the radiation sensitive element in the detector, which are important parameters in the theoretical model, does not improve the overall correlation between theory and experiment. It is concluded that disagreement between theoretical and experimental RE-values below 1.5 MeV/amu is partly due to lack of equivalence between the delta-ray spectrum and the slowing down spectrum of electrons from low-LET radiation, and partly from approximations in the calculated distribution of energy deposition of the delta-rays. (orig.)

  10. Dose properties of x-ray beams produced by laser-wakefield-accelerated electrons

    International Nuclear Information System (INIS)

    Kainz, K K; Hogstrom, K R; Antolak, J A; Almond, P R; Bloch, C D

    2005-01-01

    Given that laser wakefield acceleration (LWFA) has been demonstrated experimentally to accelerate electron beams to energies beyond 25 MeV, it is reasonable to assess the ability of existing LWFA technology to compete with conventional radiofrequency linear accelerators in producing electron and x-ray beams for external-beam radiotherapy. We present calculations of the dose distributions (off-axis dose profiles and central-axis depth dose) and dose rates of x-ray beams that can be produced from electron beams that are generated using state-of-the-art LWFA. Subsets of an LWFA electron energy distribution were propagated through the treatment head elements (presuming an existing design for an x-ray production target and flattening filter) implemented within the EGSnrc Monte Carlo code. Three x-ray energy configurations (6 MV, 10 MV and 18 MV) were studied, and the energy width ΔE of the electron-beam subsets varied from 0.5 MeV to 12.5 MeV. As ΔE increased from 0.5 MeV to 4.5 MeV, we found that the off-axis and central-axis dose profiles for x-rays were minimally affected (to within about 3%), a result slightly different from prior calculations of electron beams broadened by scattering foils. For ΔE of the order of 12 MeV, the effect on the off-axis profile was of the order of 10%, but the central-axis depth dose was affected by less than 2% for depths in excess of about 5 cm beyond d max . Although increasing ΔE beyond 6.5 MeV increased the dose rate at d max by more than 10 times, the absolute dose rates were about 3 orders of magnitude below those observed for LWFA-based electron beams at comparable energies. For a practical LWFA-based x-ray device, the beam current must be increased by about 4-5 orders of magnitude. (note)

  11. Measurement of the 0.511 MeV #betta# ray line from the galactic center

    International Nuclear Information System (INIS)

    Jardim, J.O.D.; Benson, J.L.; Jardim, M.V.A.; Martin, I.M.

    1981-02-01

    The detection of the 0.511 MeV electron-positron annihilation line coming from the Galactic Center can provide the means to estimate the rate of positron production and to test some theoretical sources of positrons. The result of the measurements of the 0.511 MeV line flux made in a gamma-ray experiment on board a stratospheric balloon is presented. Thedetector field of view looked at the galactic longitude range-31 0 0 . The observed flux is (6.70 + - 0.85)x10 - 3 photons cm - 2 s - 1 , which is in good agreement with the expected flux when assuming that the Galactic Center is a line source emitting uniformly. (Author) [pt

  12. Electrical properties of gallium arsenide irradiated with electrons and neutrons

    International Nuclear Information System (INIS)

    Kol'chenko, T.I.; Lomako, V.M.

    1975-01-01

    A study was made of changes in the electrical properties of GaAs doped with Te, S, Se, Si, Ge, Sn (n 0 approximately 10 16 -10 18 cm -3 ) and irradiated either with 2.5-28 MeV electrons or with fast reactor neutrons. An analysis of changes in the electron density indicated that the rate of carrier removal by electron bombardment was independent of the dopant but was governed by isolated radiation defects. The change in the mobility due to irradiation with 2.5-10 MeV electrons was also governed by isolated defects. When the electron energy was increased to 28 MeV the main contribution to the change in the mobility was made by defect clusters. In the neutron-irradiation case the changes in the carrier density and mobility were mainly due to defect clusters and the nature of changes in the electrical properties was again independent of the dopant

  13. Development of electron beam facilities for research and applications in Thailand

    International Nuclear Information System (INIS)

    Vilaithong, Thiraphat

    2004-01-01

    Linear accelerators (linac) were introduced into the Kingdom of Thailand almost twenty years ago. They were installed at major hospitals around the country for radiotherapy. At present there are 20 medical electron linacs in Thailand. Three of the new linacs are recently installed at Chiang Mai University Hospital. The first industrial electron accelerator was commissioned in 1997 for sterilization of medical products such as doctor gown, pampas etc. for export. It has accelerating voltage in the range between 1.8 to 2.4 MeV and power of 10 kW. The second electron accelerator was introduced in the year 2000 for gemstone enhancement. This one is a 15 MeV, 8.5 kW electron linac. Since 2000 a program to generate electron beams for research and industrial application has been realized at Chiang Mai University. Both high (10-30 MeV) and low (300 keV) energy electron accelerating systems are being explored. Here we describe the present development status and near future applications. (author)

  14. Status report of the S-DALINAC polarized electron injector SPIN at Darmstadt

    Energy Technology Data Exchange (ETDEWEB)

    Eckardt, Christian; Bahlo, Thore; Bangert, Phillip; Barday, Roman; Bonnes, Uwe; Brunken, Marco; Eichhorn, Ralf; Enders, Joachim; Platz, Markus; Poltoratska, Yuliya; Roth, Markus; Schneider, Fabian; Wagner, Markus; Weber, Antje; Zwicker, Benjamin [Institut fuer Kernphysik, Technische Universitaet Darmstadt (Germany); Ackermann, Wolfgang; Mueller, Wolfgang F.O.; Weiland, Thomas [Institut fuer Theorie Elektromagnetischer Felder, Technische Universitaet Darmstadt (Germany)

    2010-07-01

    At the superconducting 130 MeV Darmstadt electron linac S-DALINAC a source of polarized electrons is being installed. Polarized electrons are produced by photoemission from a negative electron affinity strained superlattice GaAs cathode and preaccelerated to 100 keV. With a Wien filter and Mott polarimeter in the beam line the polarization is manipulated and measured. For beam diagnostics wire scanners, fluorescent screens and a coaxial Faraday cup are included. To measure the beam polarization at higher energies, a 5-10 MeV Mott polarimeter and a 50-130 MeV Moeller polarimeter as well as a Compton transmission polarimeter will be installed. We report on the status of the implementation and show plans for future development and experiments.

  15. Probing the Cosmic X-Ray and MeV Gamma-Ray Background Radiation through the Anisotropy

    Energy Technology Data Exchange (ETDEWEB)

    Inoue, Yoshiyuki [Stanford Univ., CA (United States). Kavli Inst. for Particle Astrophysics and Cosmology; SLAC National Accelerator Lab., Menlo Park, CA (United States); Murase, Kohta [Inst. for Advanced Study, Princeton, NJ (United States). School of Natural Sciences; Madejski, Grzegorz M. [Stanford Univ., CA (United States). Kavli Inst. for Particle Astrophysics and Cosmology; SLAC National Accelerator Lab., Menlo Park, CA (United States); Uchiyama, Yasunobu [Stanford Univ., CA (United States). Kavli Inst. for Particle Astrophysics and Cosmology; SLAC National Accelerator Lab., Menlo Park, CA (United States); Rikkyo Univ., Tokyo (Japan). Dept. of Physics

    2013-09-24

    While the cosmic soft X-ray background is very likely to originate from individual Seyfert galaxies, the origin of the cosmic hard X-ray and MeV gamma-ray background is not fully understood. It is expected that Seyferts including Compton thick population may explain the cosmic hard X-ray background. At MeV energy range, Seyferts having non-thermal electrons in coronae above accretion disks or MeV blazars may explain the background radiation. We propose that future measurements of the angular power spectra of anisotropy of the cosmic X-ray and MeV gamma-ray backgrounds will be key to deciphering these backgrounds and the evolution of active galactic nuclei (AGNs). As AGNs trace the cosmic large-scale structure, spatial clustering of AGNs exists. We show that e-ROSITA will clearly detect the correlation signal of unresolved Seyferts at 0.5-2 keV and 2-10 keV bands and will be able to measure the bias parameter of AGNs at both bands. Once the future hard X-ray all sky satellites achieve the sensitivity better than 10-12 erg/cm2/s-1 at 10-30 keV or 30-50 keV - although this is beyond the sensitivities of current hard X-ray all sky monitors - angular power spectra will allow us to independently investigate the fraction of Compton-thick AGNs in all Seyferts. We also find that the expected angular power spectra of Seyferts and blazars in the MeV range are different by about an order of magnitude, where the Poisson term, so-called shot noise, is dominant. Current and future MeV instruments will clearly disentangle the origin of the MeV gamma-ray background through the angular power spectrum.

  16. Probing the cosmic x-ray and MeV gamma ray background radiation through the anisotropy

    Energy Technology Data Exchange (ETDEWEB)

    Inoue, Yoshiyuki [Stanford Univ., CA (United States); Murase, Kohta [Inst. for Advanced Study, Princeton, NJ (United States); Madejski, Grzegorz M. [Stanford Univ., CA (United States); Uchiyama, Yasunobu [Stanford Univ., CA (United States); Rikkyo Univ., Tokyo (Japan)

    2013-09-24

    While the cosmic soft X-ray background is very likely to originate from individual Seyfert galaxies, the origin of the cosmic hard X-ray and MeV gamma-ray background is not fully understood. It is expected that Seyferts including Compton thick population may explain the cosmic hard X-ray background. At MeV energy range, Seyferts having non-thermal electrons in coronae above accretion disks or MeV blazars may explain the background radiation. We propose that future measurements of the angular power spectra of anisotropy of the cosmic X-ray and MeV gamma-ray backgrounds will be key to deciphering these backgrounds and the evolution of active galactic nuclei (AGNs). As AGNs trace the cosmic large-scale structure, spatial clustering of AGNs exists. We show that e-ROSITA will clearly detect the correlation signal of unresolved Seyferts at 0.5-2 keV and 2-10 keV bands and will be able to measure the bias parameter of AGNs at both bands. Once future hard X-ray all sky satellites achieve a sensitivity better than 10–12 erg cm–2 s–1 at 10-30 keV or 30-50 keV—although this is beyond the sensitivities of current hard X-ray all sky monitors—angular power spectra will allow us to independently investigate the fraction of Compton-thick AGNs in all Seyferts. We also find that the expected angular power spectra of Seyferts and blazars in the MeV range are different by about an order of magnitude, where the Poisson term, so-called shot noise, is dominant. Current and future MeV instruments will clearly disentangle the origin of the MeV gamma-ray background through the angular power spectrum.

  17. Photon and electron collimator effects on electron output and abutting segments in energy modulated electron therapy

    International Nuclear Information System (INIS)

    Olofsson, Lennart; Karlsson, Magnus G.; Karlsson, Mikael

    2005-01-01

    In energy modulated electron therapy a large fraction of the segments will be arranged as abutting segments where inhomogeneities in segment matching regions must be kept as small as possible. Furthermore, the output variation between different segments should be minimized and must in all cases be well predicted. For electron therapy with add-on collimators, both the electron MLC (eMLC) and the photon MLC (xMLC) contribute to these effects when an xMLC tracking technique is utilized to reduce the x-ray induced leakage. Two add-on electron collimator geometries have been analyzed using Monte Carlo simulations: One isocentric eMLC geometry with an isocentric clearance of 35 cm and air or helium in the treatment head, and one conventional proximity geometry with a clearance of 5 cm and air in the treatment head. The electron fluence output for 22.5 MeV electrons is not significantly affected by the xMLC if the shielding margins are larger than 2-3 cm. For small field sizes and 9.6 MeV electrons, the isocentric design with helium in the treatment head or shielding margins larger than 3 cm is needed to avoid a reduced electron output. Dose inhomogeneity in the matching region of electron segments is, in general, small when collimator positions are adjusted to account for divergence in the field. The effect of xMLC tracking on the electron output can be made negligible while still obtaining a substantially reduced x-ray leakage contribution. Collimator scattering effects do not interfere significantly when abutting beam techniques are properly applied

  18. Electron Microscope Center Opens at Berkeley.

    Science.gov (United States)

    Robinson, Arthur L.

    1981-01-01

    A 1.5-MeV High Voltage Electron Microscope has been installed at the Lawrence Berkeley Laboratory which will help materials scientists and biologists study samples in more true-to-life situations. A 1-MeV Atomic Resolution Microscope will be installed at the same location in two years which will allow scientists to distinguish atoms. (DS)

  19. The near-infrared free-electron-laser project at Darmstadt

    International Nuclear Information System (INIS)

    Aab, V.; Alrutz-Ziemssen, K.; Genz, H.; Graef, H.D.; Richter, A.; Weise, H.

    1988-07-01

    The superconducting 130 MeV electron accelerator at Darmstadt will be modified for FEL experiments. The FEL project is planned with an electron beam in an energy range from 35 to 50 MeV corresponding to wavelengths from 4.9 to 2.4 μm. The planned FEL setup, a high current injection, the design of a hybrid undulator and the results of simulations of the FEL are presented. (orig.)

  20. Simultaneous electron capture and excitation in ion-atom collisions

    International Nuclear Information System (INIS)

    Tanis, J.A.; Bernstein, E.M.; Graham, W.G.; Clark, M.; Shafroth, S.M.; Johnson, B.M.; Jones, K.; Meron, M.

    1982-01-01

    A review of recent efforts to observe simultaneous electron capture-and-K-shell excitation in ion-atom collisions is presented. This process which has been referred to as resonant-transfer-and-excitation (RTE), is qualitatively analogous to dielectronic recombination (inverse Auger transition) in free-electron-ion collisions, and, hence, is expected to be resonant. Experimentally, events having the correct signature for simultaneous capture-and-excitation are isolated by detecting projectile K x rays in coincidence with ions which capture a single electron. In a recent experiment involving 70-160 MeV S 13+ ions incident on Ar, a maximum was observed in the yield of projectile K x rays associated with electron capture. This maximum is attributed to simultaneous capture - and excitation. The position (120 MeV) and width (60 MeV) of the observed maximum are in good agreement with theoretical calculations. The data indicate that RTE is an important mechanism for inner-shell vacancy production in the energy range studied

  1. The use of a diode matrix in commissioning activities for electron energies ≥9 MeV: A feasibility study

    International Nuclear Information System (INIS)

    Casanova Borca, Valeria; Pasquino, Massimo; Ozzello, Franca; Tofani, Santi

    2009-01-01

    The contribution of a commercially available diode matrix (MapCHECK trade mark sign , provided by Sun Nuclear, Melbourne, FL) for the commissioning procedures of the voxel based Monte Carlo (VMC++) algorithm for electron beams of MasterPlan treatment planning system was investigated. The attention is mainly focused on the calculation in homogeneous and heterogeneous phantoms. With this aim, following a data set similar to that proposed by Electron Collaborative Working Group (ECWG), the dose profiles and two-dimensional (2D) dose distributions measured by the diode matrix were compared with the calculated ones using the gamma analysis method with acceptance criteria for the dose difference and the distance to agreement equal to 4% and 4 mm, respectively. The average and standard deviation of the percentage of points satisfying the constraint γ≤1 are 98.3±4.1% and 99.3±1.7% for the 9 and 12 MeV electron beam, respectively, showing that the accuracy of MasterPlan electron beam algorithm is good for simple two-dimensional geometries as well as for more complicated three-dimensional ones. The results are in agreement with those reported in literature by Cygler et al. [''Evaluation of the first commercial Monte Carlo dose calculation engine for electron beam treatment planning,'' Med. Phys. 31, 142-153 (2004)]. In addition, the authors have also analyzed the response of the 2D array in terms of dose profiles at different depths, comparing the results with those obtained in water phantom using an electron diode. The results show that in the low gradient regions there were no deviations larger than the criteria of acceptability set by Van Dyk et al. [''Commissioning and quality assurance of treatment planning computers,'' Int. J. Radiat. Oncol. Biol. Phys. 26, 261-273 (1993)]; in the high gradient region, the maximum deviations are less than 2 mm with most of the values less than 1 mm. The present article shows that MapCHECK trade mark sign can play a useful role in

  2. Dose distribution of chest wall electron beam radiotherapy for patients with breast cancer after radical mastectomy

    International Nuclear Information System (INIS)

    Cong Yetong; Chen Dawei; Bai Lan; Zhou Yinhang; Piao Yongfeng; Wang Xi; Qu Yaqin

    2006-01-01

    Objective: To study the dose distribution of different bolus after different energy electron beam irradiation to different chest wall radiotherapy for the patients with breast cancer. Methods: The paper simulated the dose distribution of women's left breast cancer after radical mastectomy by 6 and 9 MeV electron beam irradiation, and TLD was used to measure. Results: The dose of skin became higher and the dose of lung was less when 0.5 and 1.0 cm bolus were used on the body; with the increasing of the energy of electron beam, the high dose field became larger; and with the same energy of electron beam, the high dose field moved to surface of the body when the bolus was thicker. Conclusion: When different energy electron ray irradiates different thickness bolus, the dosage of skin surface increases and the dosage of anterior margin of lung reduces. With electron ray energy increasing, the high dosage field is widen, when the electron ray energy is identity, the high dosage field migrates to the surface after adding bolus. Using certain depth bolus may attain the therapeutical dose of target area. (authors)

  3. Decontamination of drug vegetative raw material by relativistic electron beam

    International Nuclear Information System (INIS)

    Gorbanyuk, A.G.; Dikiy, I.L.; Yegorov, A.M.; Linnik, A.F.; Uskov, V.V.

    2004-01-01

    The new technology of decontamination of drug vegetative raw material and medical products is proposed. Advantages of use of relativistic beams in a range of electron energies from 0.5 MeV to 5 MeV for these purposes are shown in comparison with X-radiation of energy from 80 keV to 1 MeV

  4. Geant4 simulations of the absorption of photons in CsI and NaI produced by electrons with energies up to 4 MeV and their application to precision measurements of the β-energy spectrum with a calorimetric technique

    Science.gov (United States)

    Huyan, X.; Naviliat-Cuncic, O.; Voytas, P.; Chandavar, S.; Hughes, M.; Minamisono, K.; Paulauskas, S. V.

    2018-01-01

    The yield of photons produced by electrons slowing down in CsI and NaI was studied with four electromagnetic physics constructors included in the Geant4 toolkit. The subsequent absorption of photons in detector geometries used for measurements of the β spectrum shape was also studied with a focus on the determination of the absorption fraction. For electrons with energies in the range 0.5-4 MeV, the relative photon yields determined with the four Geant4 constructors differ at the level of 10-2 in amplitude and the relative absorption fractions differ at the level of 10-4 in amplitude. The differences among constructors enabled the estimation of the sensitivity to Geant4 simulations for the measurement of the β energy spectrum shape in 6He decay using a calorimetric technique with ions implanted in the active volume of detectors. The size of the effect associated with photons escaping the detectors was quantified in terms of a slope which, on average, is respectively - 5 . 4 %/MeV and - 4 . 8 %/MeV for the CsI and NaI geometries. The corresponding relative uncertainties as determined from the spread of results obtained with the four Geant4 constructors are 0.0067 and 0.0058.

  5. Preliminary conceptual design for a 510 MeV electron/positron injector for a UCLA φ factory

    International Nuclear Information System (INIS)

    Dahlbacka, G.; Hartline, R.; Barletta, W.; Pellegrini, C.

    1991-01-01

    UCLA is proposing a compact suer conducting high luminosity (10 32-33 cm -2 sec -1 ) e + e - collider for a φ factory. To achieve the required e + e - currents, full energy injections from a linac with intermediate storage in a Positron Accumulator Ring (PAR) is used. The elements of the linac are outlined with cost and future flexibility in mind. The preliminary conceptual design starts with a high current gun similar in design to those developed at SLAC and at ANL (for the APS). Four 4-section linac modules follow, each driven by a 60 MW klystron with a 1 μsec macropulse and an average current of 8.6 A. The first 4-section model is used to create positrons in a tungsten target at 186 MeV. The three remaining three modules are used to accelerate the e + e - beam to 558 MeV (no load limit) for injection into the PAR

  6. A comparison of ionizing radiation damage in CMOS devices from 60Co gamma rays, electrons and protons

    International Nuclear Information System (INIS)

    He Baoping; Yao Zhibin; Zhang Fengqi

    2009-01-01

    Radiation hardened CC4007RH and non-radiation hardened CC4011 devices were irradiated using 60 Co gamma rays, 1 MeV electrons and 1-9 MeV protons to compare the ionizing radiation damage of the gamma rays with the charged particles. For all devices examined, with experimental uncertainty, the radiation induced threshold voltage shifts (ΔV th ) generated by 60 Co gamma rays are equal to that of 1 MeV electron and 1-7 MeV proton radiation under 0 gate bias condition. Under 5 V gate bias condition, the distinction of threshold voltage shifts (ΔV th ) generated by 60 Co gamma rays and 1 MeV electrons irradiation are not large, and the radiation damage for protons below 9 MeV is always less than that of 60 Co gamma rays. The lower energy the proton has, the less serious the radiation damage becomes. (authors)

  7. Calculating Rayleigh scattering amplitudes from 100 eV to 10 MeV

    International Nuclear Information System (INIS)

    Parker, J.C.; Reynaud, G.W.; Botto, D.J.; Pratt, R.H.

    1979-01-01

    An attempt is made to explain how to calculate the contribution to elastic photon-atom scattering due to Rayleigh scattering (the scattering off bound electrons) in the photon energy range 100 eV less than or equal to W less than or equal to 10 MeV. All intermediate calculations are described, including the calculation of the potential, bound state wave functions, matrix elements, and final cross sections. 12 references

  8. The 665 KeV preinjector for the Nimrod 70 MeV injector

    International Nuclear Information System (INIS)

    Fowler, R.G.; Sidlow, R.; West, N.D.

    1976-09-01

    The preinjector for the new 70 MeV injector is described. A small duoplasmatron ion source supplies protons to the medium gradient accelerating column which is inside a glass fibre outer tube. The interspace between the column and outer tube contains sulphur hexafluoride gas as insulant. An HT platform, located close to the ion source end of the preinjector, contains the electronic power supplies necessary for the source. (author)

  9. Longitudinal phase-space matching between microtrons at 185 MeV

    International Nuclear Information System (INIS)

    Takeda, H.

    1983-01-01

    Electrons are accelerated to 185 MeV by a microtron. Then, they are injected into another microtron to boost the net energy up to a few GeV. Between the two microtrons both longitudinal and transverse phase-space matching are required. In this paper, we consider a longitudinal phase-ellipse matching which utilizes triple left-right-left sector dipoles to induce a negative phase-angle shear. This is accomplished because a high-energy particle travels a shorter distance through the dipole system than a low-energy particle

  10. Long-term preservation of bacon by high energy electrons

    International Nuclear Information System (INIS)

    Hannah, K.W.; Simic, M.G.

    1985-01-01

    Extra long-term storage of frozen, vacuum packed, cured bacon can be achieved by electronation, using 3 MeV electrons generated by an electron accelerator. A combination process consisting of low nitrite curing (40 ppm), smoking, vacuum packaging in Saran plastic, electronation (1 to 3 Mrad), and freezing (-10 C) allows storage for at least 2 1/2 years without any noticeable loss in quality, e.g. color, appearance, smell, or taste. This process also eliminates microbiological hazards associated with Salmonella and C. botulinum. Six Mrad tons/hour throughput of a 3 MeV 50 kw electron beam accelerator for standard sliced bacon packaging indicates a practical and economic commercial use for this combination process. (author)

  11. Electron polarimetry at low energies in Hall C at JLab

    International Nuclear Information System (INIS)

    Gaskell, D.

    2013-01-01

    Although the majority of Jefferson Lab experiments require multi-GeV electron beams, there have been a few opportunities to make electron beam polarization measurements at rather low energies. This proceedings will discuss some of the practical difficulties encountered in performing electron polarimetry via Mo/ller scattering at energies on the order of a few hundred MeV. Prospects for Compton polarimetry at very low energies will also be discussed. While Mo/ller scattering is likely the preferred method for electron polarimetry at energies below 500 MeV, there are certain aspects of the polarimeter and experiment design that must be carefully considered

  12. Bread-Board Testing of the Radiation Hard Electron Monitor (RADEM) being developed for the ESA JUICE Mission

    Science.gov (United States)

    Mrigakshi, Alankrita; Hajdas, Wojtek; Marcinkowski, Radoslaw; Xiao, Hualin; Goncalves, Patricia; Pinto, Marco; Pinto, Costa; Marques, Arlindo; Meier, Dirk

    2016-04-01

    The RADEM instrument will serve as the radiation monitor for the JUICE spacecraft. It will characterize the highly dynamic radiation environment of the Jovian system by measuring the energy spectra of energetic electrons and protons up to 40 MeV and 250 MeV, respectively. It will also determine the directionality of 0.3-10 MeV electrons. Further goals include the detection of heavy ions, and the determination of the corresponding LET spectra and dose rates. Here, the tests of the Electron and Proton Telescopes, and the Directionality Detector of the RADEM Bread-Board model are described. The objective of these tests is to validate RADEM design and physical concept applied therein. The tests were performed at various irradiation facilities at the Paul Scherrer Institute (PSI) where energy ranges relevant for space applications can be covered (electrons: ≤100 MeV and protons: ≤230 MeV). The measured values are also compared with GEANT4 Monte-Carlo Simulation results.

  13. Electromagnetic cascades produced by gamma-quanta with the energy Eγ=100-3500 MeV

    International Nuclear Information System (INIS)

    Slowinski, B.

    1990-01-01

    Fluctuations of the electron ionization loss (IL) in electromagnetic showers produced by gamma-quanta of energy E γ between 100 and 3500 MeV have been studied using pictures of the 180 l xenon bubble chamber of ITEP (Moscow). The distribution of the standard deviation σ A of the part A of the IL released along the shower axis and in its lateral direction was obtained and found to be approximately independent of Eγ at Eγ≥500 MeV when expressed as a fuction of A and normalized to maximum value of the σ A in the case of the lateral shower development. The relative spread of the average longitudinal and lateral e.m. shower dimensions are discussed too. 18 refs.; 4 figs

  14. Defect production and annihilation in metals through electronic excitation by energetic heavy ion bombardment

    Energy Technology Data Exchange (ETDEWEB)

    Iwase, Akihiro [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1997-03-01

    Defect production, radiation annealing and defect recovery are studied in Ni and Cu irradiated with low-energy ({approx}1-MeV) and high-energy ({approx}100-MeV) ions. Irradiation of Ni with {approx}100-MeV ions causes an anomalous reduction, or even a complete disappearance of the stage-I recovery. This result shows that the energy transferred from excited electrons to lattice atoms through the electron-lattice interaction contributes to the annihilation of the stage-I interstitials. This effect is also observed in Ni as a large radiation annealing during 100-MeV heavy ion irradiation. On the other hand, in Cu thin foils, we find the defect production process strongly associated with electron excitation, where the defect production cross section is nearly proportional to S{sub e}{sup 2}. (author)

  15. Electron-electron bound states in Maxwell-Chern-Simons-Proca QED{sub 3}

    Energy Technology Data Exchange (ETDEWEB)

    Belich, H.; Helayel-Neto, J.A. [Grupo de Fisica Teorica Jose Leite Lopes, Petropolis, RJ (Brazil)]|[Centro Brasileiro de Pesquisas Fisicas (CBPF), Rio de Janeiro, RJ (Brazil). Coordenacao de Teoria de Campos e Particulas]. E-mail: belich@cbpf.br; helayel@gft.ucp.br; Del Cima, O.M. [Grupo de Fisica Teorica Jose Leite Lopes, Petropolis, RJ (Brazil)]. E-mail: delcima@gft.ucp.br; Ferreira, M.M. Jr. [Grupo de Fisica Teorica Jose Leite Lopes, Petropolis, RJ (Brazil)]|[Maranhao Univ., Sao Luis, MA (Brazil). Dept. de Fisica]. E-mail: manojr@cbpf.br

    2002-10-01

    We start from a parity-breaking MCS QED{sub 3} model with spontaneous breaking of the gauge symmetry as a framework for evaluation of the electron-electron interaction potential and for attainment of numerical values for the e{sup -}e{sup -} - bound state. Three expressions (V{sub eff{down_arrow}}{sub {down_arrow}}, V{sub eff{down_arrow}}{sub {up_arrow}}, V{sub eff{down_arrow}}{sub {down_arrow}}) are obtained according to the polarization state of the scattered electrons. In an energy scale compatible with condensed matter electronic excitations, these potentials become degenerated. The resulting potential is implemented in the Schroedinger equation and the variational method is applied to carry out the electronic binding energy. The resulting binding energies in the scale of 10-100 meV and a correlation length in the scale of 10 - 30 Angstrom are possible indications that the MCS-QED{sub 3} model adopted may be suitable to address an eventual case of e{sup -}e{sup -} pairing in the presence of parity-symmetry breakdown. The data analyzed here suggest an energy scale of 10-100 meV to fix the breaking of the U(1)-symmetry. (author)

  16. Radiation safety considerations for operation of a portable 6 MeV electron linear accelerator

    International Nuclear Information System (INIS)

    Schonberg, R.G.

    1987-01-01

    Field use of the ''MINAC'' presents some unique problems. There are some high voltage electrical safety problems, but these pale in comparison to the radiation related problems. The perimeter limits are determined by a combination of leakage and scatter. In most cases, the boundary limit is determined by scatter. Localized shielding can be applied to reduce scatter which is primarily of rest-mass energy (0.511 MeV). Careful primary beam collimating can also be used to reduce the radiation hazard

  17. Effect of substrate temperature on the radiation damage from MeV Si implantation in Si

    International Nuclear Information System (INIS)

    Yu, X.K.; Shao Lin; Rusakova, Irene; Wang, X.M.; Ma, K.B.; Chen, H.; Liu, Jiarui; Chu, W.-K.

    2006-01-01

    We have investigated the radiation damage by MeV implantation of Si in Si and its evolution under thermal annealing. Si wafers were implanted with MeV Si at various substrate temperatures. Damages were characterized by Rutherford-backscattering (RBS) channeling and by transmission electron microscopy (TEM). Defect formation after post-implantation annealing is very sensitive to the substrate temperatures during implantation. When the substrate temperature was decreased to 200 K, TEM revealed two distinct bands of damage after annealing: one around the mean projected ion range and another at half the projected range. Our study indicates that the formation of defects at half range results from the solid phase epitaxy growth of initial buried amorphous layers

  18. Secondary electron emission of thin carbon foils under the impact of hydrogen atoms, ions and molecular ions, under energies within the MeV range; Multiplicite des electrons secondaires emis par des cibles minces de carbone sous l'impact de projectiles H0, H2+, H3+ d'energie de l'ordre du MeV

    Energy Technology Data Exchange (ETDEWEB)

    Vidovic, Z

    1997-06-15

    This work focuses on the study of the emission statistics of secondary electrons from thin carbon foils bombarded with H{sup 0}, H{sub 2}{sup +} and H{sub 3}{sup +} projectiles in the 0.25-2.2 MeV energy range. The phenomenon of secondary electron emission from solids under the impact of swift ions is mainly due to inelastic interactions with target electrons. The phenomenological and theoretical descriptions, as well as a summary of the main theoretical models are the subject of the first chapter. The experimental set-up used to measure event by event the electron emission of the two faces of a thin carbon foil traversed by an energetic projectile is described in the chapter two. In this chapter are also presented the method and algorithms used to process experimental spectra in order to obtain the statistical distribution of the emitted electrons. Chapter three presents the measurements of secondary electron emission induced by H atoms passing through thin carbon foils. The secondary electron yields are studied in correlation with the emergent projectile charge state. We show the peculiar role of the projectile electron, whether it remains or not bound to the incident proton. The fourth chapter is dedicated to the secondary electron emission induced by H{sub 2}{sup +} and H{sub 3}{sup +} polyatomic ions. The results are interpreted in terms of collective effects in the interactions of these ions with solids. The role of the proximity of the protons, molecular ion fragments, upon the amplitude of these collective effects is evidenced from the study of the statistics of forward emission. These experiences allowed us to shed light on various aspects of atom and polyatomic ion inter-actions with solid surfaces. (author)

  19. A 14-MeV beam-plasma neutron source for materials testing

    International Nuclear Information System (INIS)

    Futch, A.H.; Coensgen, F.H.; Damm, C.C.; Molvik, A.W.

    1989-01-01

    The design and performance of 14-MeV beam-plasma neutron sources for accelerated testing of fusion reactor materials are described. Continuous production of 14-MeV neutron fluxes in the range of 5 to 10 MW/m 2 at the plasma surface are produced by D-T reactions in a two-component plasma. In the present designs, 14-MeV neutrons result from collisions of energetic deuterium ions created by transverse injection of 150-keV deuterium atoms on a fully ionized tritium target plasma. The beam energy, which deposited at the center of the tritium column, is transferred to the warm plasma by electron drag, which flows axially to the end regions. Neutral gas at high pressure absorbs the energy in the tritium plasma and transfers the heat to the walls of the vacuum vessel. The plasma parameters of the neutron source, in dimensionless units, have been achieved in the 2XIIB high-β plasma. The larger magnetic field of the present design permits scaling to the higher energy and density of the neutron source design. In the extrapolation, care has been taken to preserve the scaling and plasma attributes that contributed to equilibrium, magnetohydrodynamic (MHD) stability, and microstability in 2XIIB. The performance and scaling characteristics are described for several designs chosen to enhance the thermal isolation of the two-component plasmas. 11 refs., 3 figs., 3 tabs

  20. Response of zircon to electron and Ne+ irradiation

    International Nuclear Information System (INIS)

    Devanathan, R.; Weber, W.J.; Boatner, L.A.

    1997-01-01

    Zircon (ZrSiO 4 ) is an actinide host phase in vitreous ceramic nuclear waste forms and a potential host phase for the disposition of excess weapons plutonium. In the present work, the effects of 800 and 900 keV electron and 1 MeV Ne + irradiations on the structure of single crystals of ZrSiO 4 have been investigated. The microstructural evolution during the irradiations was studied in situ using a high-voltage electron microscope interfaced to an ion accelerator at Argonne National Laboratory. The results indicate that electron irradiation at 15 K cannot amorphize ZrSiO 4 even at fluences an order of magnitude higher than that required for amorphization by 1.5 MeV Kr + ions. However, the material is readily amorphized by 1 MeV Ne + irradiation at 15 K. The temperature dependence of this amorphization is discussed in light of previous studies of radiation damage in ZrSiO 4

  1. All-Optical Electron Injector

    Science.gov (United States)

    Umstadter, Donald

    2002-04-01

    Conventional electron acceleration at a place like SLAC needs miles to boost particles up to 50 GeV energies by feeding microwaves into a succession of cavities. In recent years we have been developing alternative acceleration concepts, based on lasers focused into plasmas, that might someday do the job in a much smaller space without the use of cavities. Our near term goal is to produce a first stage accelerator that outputs electron beams with lower energy but with properties that are more suitable for x-ray sources, such as those based on Compton scattering or the proposed linear synchrotrons at SLAC and DESY. In the plasma wakefield approach, for example, a terawatt laser beam is focused onto a gas jet, ionizing it and driving plasma waves that move at relativistic speeds. If timed just right, electrons in the plasma can surf the plasma waves to high speeds, as high as 100 MeV in the space of only a millimeter. NanoCoulombs of charge have been accelerated in well-collimated beams (1-degree divergence angle). One problem with this concept is the mismatch between the electron source (sometimes an external photocathode, sometimes an uncontrolled cloud of electrons from the plasma itself) and the incoming laser pulse. We will be reporting methods for generating electrons in a controllable way, namely the use of a pair of crossed laser beams which position, heat, and synchronize the insertion of electrons into the plasma wave. We show that this "all-optical injection" increases the number and energy of energetic electrons as compared with use of only one laser beam. It has been shown theoretically that this approach can ultimately be used to reduce the electron energy spread to a few percent. Besides potential applications to particle physics and x-ray lasers, high gradient acceleration schemes are also expected to benefit the production of medical radioisotopes and the ignition of thermonuclear fusion reactions.

  2. Electron-Positron Accumulator (EPA)

    CERN Multimedia

    Photographic Service

    1986-01-01

    After acceleration in the low-current linac LIL-W, the electrons and positrons are accumulated in EPA to obtain a sufficient intensity and a suitable time-structure, before being passed on to the PS for further acceleration to 3.5 GeV. Electrons circulate from right to left, positrons in the other direction. Dipole bending magnets are red, focusing quadrupoles blue, sextupoles for chromaticity-control orange. The vertical tube at the left of the picture belongs to an optical transport system carrying the synchrotron radiation to detectors for beam size measurement. Construction of EPA was completed in spring 1986. LIL-W and EPA were conceived for an energy of 600 MeV, but operation was limited to 500 MeV.

  3. Experimental validation of the DPM Monte Carlo code using minimally scattered electron beams in heterogeneous media

    International Nuclear Information System (INIS)

    Chetty, Indrin J.; Moran, Jean M.; Nurushev, Teamor S.; McShan, Daniel L.; Fraass, Benedick A.; Wilderman, Scott J.; Bielajew, Alex F.

    2002-01-01

    A comprehensive set of measurements and calculations has been conducted to investigate the accuracy of the Dose Planning Method (DPM) Monte Carlo code for electron beam dose calculations in heterogeneous media. Measurements were made using 10 MeV and 50 MeV minimally scattered, uncollimated electron beams from a racetrack microtron. Source distributions for the Monte Carlo calculations were reconstructed from in-air ion chamber scans and then benchmarked against measurements in a homogeneous water phantom. The in-air spatial distributions were found to have FWHM of 4.7 cm and 1.3 cm, at 100 cm from the source, for the 10 MeV and 50 MeV beams respectively. Energy spectra for the electron beams were determined by simulating the components of the microtron treatment head using the code MCNP4B. Profile measurements were made using an ion chamber in a water phantom with slabs of lung or bone-equivalent materials submerged at various depths. DPM calculations are, on average, within 2% agreement with measurement for all geometries except for the 50 MeV incident on a 6 cm lung-equivalent slab. Measurements using approximately monoenergetic, 50 MeV, 'pencil-beam'-type electrons in heterogeneous media provide conditions for maximum electronic disequilibrium and hence present a stringent test of the code's electron transport physics; the agreement noted between calculation and measurement illustrates that the DPM code is capable of accurate dose calculation even under such conditions. (author)

  4. Backscattered electron emission after proton impact on carbon and gold films: Experiments and simulations

    Energy Technology Data Exchange (ETDEWEB)

    Hespeels, F.; Heuskin, A.C. [University of Namur, PMR, 61 rue de Bruxelles, B-5000 Namur (Belgium); Scifoni, E. [TIFPA-INFN, Trento Institute for Fundamental Physics and Applications, Via Sommarive 14, I-38123 Trento (Italy); GSI-Helmholtzzentrum für Schwerionenforschung, Biophysik, Max Planck-Strasse 1, D-64291 Darmstadt (Germany); Kraemer, M. [GSI-Helmholtzzentrum für Schwerionenforschung, Biophysik, Max Planck-Strasse 1, D-64291 Darmstadt (Germany); Lucas, S., E-mail: stephane.lucas@unamur.be [University of Namur, PMR, 61 rue de Bruxelles, B-5000 Namur (Belgium)

    2017-06-15

    This work aims at measuring the proton induced secondary electron energy spectra from nanometer thin films. Backscattered electron energy spectra were measured within an energy range from 0 to 600 eV using a Retarding Field Analyser (RFA). This paper presents energy spectra obtained for proton (0.5 MeV; 1 MeV; 1.5 MeV; 2 MeV) irradiation of thin carbon films (50 and 100 nm thick) and thin gold film (200 nm). These experimental spectra were compared with Monte Carlo simulations based on TRAX code and Geant4 simulation toolkit. Good agreement between experimental, TRAX and Geant4 results were observed for the carbon target. For the gold target, we report major differences between both Monte Carlo environments. Limitation of Geant4 models for low energy electron emission was highlighted. On the contrary, TRAX simulations present encouraging results for the modeling of low-energy electron emission from gold target.

  5. An Inverse Free-Electron-Laser accelerator

    International Nuclear Information System (INIS)

    Fisher, A.S.; Gallardo, J.C.; van Steenbergen, A.; Ulc, S.; Woodle, M.; Sandweiss, J.; Fang, Jyan-Min

    1993-01-01

    Recent work at BNL on electron acceleration using the Inverse Free-Electron Laser (IFEL) has considered a low-energy, high-gradient, multi-stage linear accelerator. Experiments are planned at BNL's Accelerator Test Facility using its 50-MeV linac and 100-GW CO 2 laser. We have built and tested a fast-excitation wiggler magnet with constant field, tapered period, and overall length of 47 cm. Vanadium-Permendur ferromagnetic laminations are stacked in alternation with copper, eddy-current-induced, field reflectors to achieve a 1.4-T peak field with a 4-mm gap and a typical period of 3 cm. The laser beam will pass through the wiggler in a low-loss, dielectric-coated stainless-steel, rectangular waveguide. The attenuation and transverse mode has been measured in waveguide sections of various lengths, with and without the dielectric. Results of 1-D and 3-D IFEL simulations, including wiggler errors, will be presented for several cases: the initial, single-module experiment with ΔE = 39 MeV, a four-module design giving ΔE = 100 MeV in a total length of 2 m, and an eight-module IFEL with ΔE = 210 MeV

  6. Study of the gamma spectra emitted in a nuclear reaction - Measurement of the half-lives of the levels 6.13 MeV, 6.92 MeV and 7.12 MeV of 16O

    International Nuclear Information System (INIS)

    Leccia, F.

    1967-01-01

    When the energy shifts of the gamma spectrum released during a nuclear reaction are important compared with the detector resolution, the comparison of the experimental spectrum with theoretical spectra allows us to determine the half-life of the initial state of the transition. The calculation of the experimental spectrum implies to know the slowing-down of the recoil nucleus in the matter in order to take into account the Doppler effect. For recoil energies in the range of the MeV and for solid media, the Lindhard theory agrees well with experimental data. The phenomenon of deflection which appears at very low energies must be taken into account by restraining the measurement domain. By choosing an adequate media we can measure half-lives in the domain 1 and 100 fs without needing to take into account deflection effects. We have measured the half-life of the first 3 energy levels of 16 O (6.135 MeV, 6.923 MeV and 7.121 MeV), these levels are reached through the reaction 19 F(p,αγ) 16 O with proton incident energies ranging from 0.872 MeV to 2.42 MeV. We have used a coaxial germanium semi-conductor with lithium additions that was connected to an amplification line of Ortec type. 2 kinds of target have been used: calcium fluoride and copper fluoride evaporated on tantalum support. We have obtained the following values for the half-life: (16±4) fs for the 6.923 MeV level, (18±4) fs for the 7.121 MeV level, and for the 6.135 MeV we can only give a lower limit since the gamma decay occurs when the nucleus is at rest τ > 200 fs

  7. Electron density measurements during ion beam transport on Gamble II

    International Nuclear Information System (INIS)

    Weber, B.V.; Hinshelwood, D.D.; Neri, J.M.; Ottinger, P.F.; Rose, D.V.; Stephanakis, S.J.; Young, F.C.

    1999-01-01

    High-sensitivity laser interferometry was used to measure the electron density created when an intense proton beam (100 kA, 1 MeV, 50 ns) from the Gamble II generator was transported through low-pressure gas as part of a project investigating Self-Pinched Transport (SPT) of intense ion beams. This measurement is non-perturbing and sufficiently quantitative to allow benchmarking of codes (particularly IPROP) used to model beam-gas interaction and ion-beam transport. Very high phase sensitivity is required for this measurement. For example, a 100-kA, 1-MeV, 10-cm-radius proton beam with uniform current density has a line-integrated proton density equal to n b L = 3 x 10 13 cm -2 . An equal electron line-density, n e L = n b L, (expected for transport in vacuum) will be detected as a phase shift of the 1.064 microm laser beam of only 0.05degree, or an optical path change of 1.4 x 10 -4 waves (about the size of a hydrogen atom). The time-history of the line-integrated electron density, measured across a diameter of the transport chamber at 43 cm from the input aperture, starts with the proton arrival time and decays differently depending on the gas pressure. The gas conditions included vacuum (10 -4 Torr air), 30 to 220 mTorr He, and 1 Torr air. The measured densities vary by three orders of magnitude, from 10 13 to 10 16 cm -2 for the range of gas pressures investigated. In vacuum, the measured electron densities indicate only co-moving electrons (n e L approximately n b L). In He, when the gas pressure is sufficient for ionization by beam particles and SPT is observed, n e L increases to about 10 n b L. At even higher pressures where electrons contribute to ionization, even higher electron densities are observed with an ionization fraction of about 2%. The diagnostic technique as used on the SPT experiment will be described and a summary of the results will be given. The measurements are in reasonable agreement with theoretical predictions from the IPROP code

  8. Radiation belt seed population and its association with the relativistic electron dynamics: A statistical study: Radiation Belt Seed Population

    International Nuclear Information System (INIS)

    Tang, C. L.; Wang, Y. X.; Ni, B.; Zhang, J.-C.

    2017-01-01

    Using the Van Allen Probes data, we study the radiation belt seed population and it associated with the relativistic electron dynamics during 74 geomagnetic storm events. Based on the flux changes of 1 MeV electrons before and after the storm peak, these storm events are divided into two groups of “non-preconditioned” and “preconditioned”. The statistical study shows that the storm intensity is of significant importance for the distribution of the seed population (336 keV electrons) in the outer radiation belt. However, substorm intensity can also be important to the evolution of the seed population for some geomagnetic storm events. For non-preconditioned storm events, the correlation between the peak fluxes and their L-shell locations of the seed population and relativistic electrons (592 keV, 1.0 MeV, 1.8 MeV, and 2.1 MeV) is consistent with the energy-dependent dynamic processes in the outer radiation belt. For preconditioned storm events, the correlation between the features of the seed population and relativistic electrons is not fully consistent with the energy-dependent processes. It is suggested that the good correlation between the radiation belt seed population and ≤1.0 MeV electrons contributes to the prediction of the evolution of ≤1.0 MeV electrons in the Earth’s outer radiation belt during periods of geomagnetic storms.

  9. Positron acceleration to 200 MeV

    International Nuclear Information System (INIS)

    Leboutet, H.

    1983-01-01

    220 MeV is the energy that has to be obtained in routine operation. A standard 12m girder with SLED II can give 220 MeV minus a few percent due to not riding at the crest of the wave. In order to have the 200 MeV with only one girder, a klystron at full power all the time would be required - kept brand new. Then, for safety it is necessary to use two klystrons as designated in the SLC design. Having two klystrons gives freedom for the choice of the best arrangement. Since there will be excess rf power, it can be traded against higher gradient, shorter waveguides, larger apertures (lower shunt impedence)

  10. Design of electron beam bending magnet system using three sector magnets for electron and photon therapy: a simulation approach

    International Nuclear Information System (INIS)

    Shahzad, A.A.; Bhoraskar, V.N.; Dhole, S.D.

    2013-01-01

    The 270 degree doubly achromatic beam bending magnet system using three sector magnets has been designed mainly for treating cancer and skin diseases. The main requirements of the design of three magnet system is to focus an electron beam having a spot size less than 3mm x 3mm, energy spread within 3% and divergence angle ≤ 3 mrad at the target. To achieve these parameters the simulation was carried out using Lorentz-3EM software. The beam spot, divergence angle and energy spread were observed with respect to the variation in angles of sector magnets and drift distances. From the simulated results, it has been optimized that all the three sector magnets has an angle of 62 degree and the drift distance 68 mm. It is also observed that at the 1637, 2425, 3278, 4165 and 5690 Amp-turn, the optimized design produces 3851, 5754, 7434, 9356 and 11425 Gauss of magnetic field at median plane require to bend 6, 9, 12, 15 and 18 MeV energy of electron respectively for electron therapy. The output parameters of the optimized design are energy spread 3%, divergence angle ∼ 3 mrad and spot size 2.8 mm. Moreover, for 6 MV and 15 MV photon therapy application, an electron beam of energy 6.5 MeV and 15.5 MeV extracted from magnet system and focussed on the Bremsstrahlung target. For the photon therapy the 1780, and 4456 amp-turn, an optimized design produces 4148 and 9682 Gauss of magnetic field at median plane require to bend 6.5 and 15.5 MeV energy of electron respectively, which further produces Bremsstrahlung in Tungsten target. (author)

  11. A comparative study of 30MeV boron4+ and 60MeV oxygen8+ ion irradiated Si NPN BJTs

    International Nuclear Information System (INIS)

    Kumar, M. Vinay; Krishnaveni, S.; Yashoda, T.; Dinesh, C. M.; Krishnakumar, K. S.; Jayashree, B.; Ramani

    2015-01-01

    The impact of 30MeV boron 4+ and 60MeV oxygen 8+ ion irradiation on electrical characteristics of 2N3773 Si NPN Bipolar junction transistors (BJTs) is reported in the present study. The transistors were decapped and irradiated at room temperature. Gummel characteristics, DC current gain and Capacitance-voltage (C-V) characteristics were studied before and after irradiation at different fluences. DC current gain has decreased significantly in both boron and oxygen ion irradiation. Also the value of capacitance decreased 3-4 times with increase in fluence. Both 30MeV boron ion and 60MeV oxygen ion induced similar extent of degradation in electrical characteristics of the transistor

  12. Laser-driven injector of electrons for IOTA

    Science.gov (United States)

    Romanov, Aleksandr

    2017-03-01

    Fermilab is developing the Integrable Optics Test Accelerator (IOTA) ring for experiments on nonlinear integrable optics. The machine will operate with either electron beams of 150 MeV or proton beams of 2.5 MeV energies, respectively. The stability of integrable optics depends critically on the precision of the magnetic lattice, which demands the use of beam-based lattice measurements for optics correction. In the proton mode, the low-energy proton beam does not represent a good probe for this application; hence we consider the use of a low-intensity reverse-injected electron beam of matched momentum (70 MeV). Such an injector could be implemented with the use of laser-driven acceleration techniques. This report presents the consideration for a laser-plasma injector for IOTA and discusses the requirements determined by the ring design.

  13. The Eindhoven High-Brightness Electron Programme

    NARCIS (Netherlands)

    Brussaard, G.J.H.; Wiel, van der M.J.

    2004-01-01

    The Eindhoven High-Brightness programme is aimed at producing ultra-short intense electron bunches from compact accelerators. The RF electron gun is capable of producing 100 fs electron bunches at 7.5 MeV and 10 pC bunch charge. The DC/RF hybrid gun under development will produce bunches <75 fs at

  14. Recoil proton polarization of neutral pion photoproduction from proton in the energy range between 400 MeV and 1142 MeV

    International Nuclear Information System (INIS)

    Kato, S.; Miyachi, T.; Sugano, K.; Toshioka, K.; Ukai, K.

    1979-08-01

    The recoil proton polarization of the reaction γp → π 0 p were measured at a C.M. angle of 100 0 for incident photon energies between 451 and 1106 MeV, and at an angle of 130 0 for energies from 400 MeV to 1142 MeV. One photon decayed from a π 0 -meson and a recoil proton were detected in coincidence. Two kinds of polarization scatterers were employed. In the range of proton kinetic energy less than 420 MeV and higher than 346 MeV, carbon plates and liquid hydrogen were used for determining the polarization. Results are compared with recent phenomenological analyses. From the Comparison between the present data and the asymmetry data given by the polarized target, the contribution of the invariant amplitudes A 3 can be estimated to be small at 100 0 . (author)

  15. Effects of 6 MeV electron irradiation on the electrical properties and device parameters of Al/Al{sub 2}O{sub 3}/TiO{sub 2}/n-Si MOS capacitors

    Energy Technology Data Exchange (ETDEWEB)

    Laha, P.; Banerjee, I.; Barhai, P.K. [Department of Applied Physics, Birla Institute of Technology, Mesra, Ranchi 835215 (India); Das, A.K. [Laser and Plasma Technology Division, Bhabha Atomic Research Center, Mumbai 400085 (India); Bhoraskar, V.N. [Department of Physics, University of Pune, Ganeshkhind, Pune 411007 (India); Mahapatra, S.K., E-mail: skm@physics.ucla.edu [Department of Applied Physics, Birla Institute of Technology, Mesra, Ranchi 835215 (India)

    2012-07-15

    Highlights: Black-Right-Pointing-Pointer The electron irradiation effects make variation in the device parameters. Black-Right-Pointing-Pointer The device parameters changes due to percentage of defects and charge trapping. Black-Right-Pointing-Pointer Leakage current of Al/Al{sub 2}O{sub 3}/TiO{sub 2}/n-Si changes due to interface dangling bonds. Black-Right-Pointing-Pointer The leakage current mechanism of MOS structures is due to Poole-Frenkel effect. - Abstract: The effects of 6 MeV electron irradiation on the electrical properties and device parameter characteristics of Al/Al{sub 2}O{sub 3}/TiO{sub 2}/n-Si metal-oxide-semiconductor capacitors have been studied. Twelve Al/Al{sub 2}O{sub 3}/TiO{sub 2}/n-Si MOS capacitors were fabricated using r.f. magnetron sputtering and divided into four groups. The first group was not irradiated and treated as virgin. The rest were irradiated with 6 MeV electrons at doses 10, 20, and 30 kGy, maintaining the dose rate at {approx}1 kGy/min. Variations in crystallinity of the virgin and irradiated capacitors were studied using grazing incident X-ray diffraction. The thickness and in-depth elemental distributions of individual layers were determined using secondary ion mass apectrometry. Capacitance-voltage, conductance-voltage and leakage current-voltage characteristics of the virgin and irradiated samples were studied. The device parameters (flat band voltage, surface charge density and interface trap density of the virgin and irradiated structures) were determined. The electrical properties of the capacitors were investigated and the Poole-Frenkel coefficient of the capacitors was determined from leakage current measurements. The leakage current mechanism has been explained.

  16. Calorimetric determination of electron beam output

    Energy Technology Data Exchange (ETDEWEB)

    Novotny, J; Kovar, Z; Jandejsek, L [Ceskoslovenska Akademie Ved, Prague. Ustav Radiologicke Dozimetrie

    1979-07-01

    Two types of portable graphite calorimeter are described having modified replaceable absorbers allowing measurements of energy flux density in betatron electron beams in a range of 4 to 50 MeV. In a range of 4 to 20 MeV the total measurement error was about 1%. The results are discussed of the standardization of Siemens and Ostron medical betatrons using the said calorimeters.

  17. Facility for electron cooling experiments

    International Nuclear Information System (INIS)

    Budker, G.I.; Dikanskij, N.S.; Kudelajnen, V.I.

    1982-01-01

    The NAP-M proton storage ring intended for electron cooling experiments is described. The NAP-M magnetic system comprises four bending magnets and eight correction elements. located at the ends of rectilinear gaps. An electron beam facility is located in one of the rectilinear gaps. An 1.5 MeV electrostatic accelerator is used as a proton injector. The NAP-M accelerating system includes a driving generator, a power amplifier and a resonator. The proton beam lifetime (at the RF-system switched-off) up to 7 s has been obtained at the NAP-N at the injection energy, and up to 600 s at 65 MeV and the proton current of 120 μA

  18. Conversion efficiency of lead for 30-200 MeV photons

    International Nuclear Information System (INIS)

    Darriulat, P.; Gygi, E.; Holder, M.; McDonald, K.T.; Pugh, H.G.; Schneider, F.; Tittel, K.

    1975-01-01

    The conversion efficiency of lead has been measured as a function of thickness for 44 MeV, 94 MeV and 177 MeV photons, and as a function of energy between 29 MeV and 177 Mev for thickness of one and two radiation lengths. Some additional information on multiplicity of secondary tracks and on their angular distribution was obtained using a small streamer chamber. The results obtained confirm the shower calculations of Messel and Crawford. (Auth.)

  19. Investigation of planar channeling radiation on diamond and quartz crystals at electron energies between 14 and 34 MeV and probing the influence of ultrasonic waves on channeling radiation

    International Nuclear Information System (INIS)

    Azadegan, B.

    2007-01-01

    Measurements of planar channeling radiation (CR) have been performed at the electron beam of ELBE within an energy range between 14 and 34 MeV and for thicknesses of the diamond crystals between 42.5 and 500 μm. Absolute CR photon yields have for the first time been obtained for the above given ranges of electron energy and crystal thickness. The square-root dependence of the planar CR photon yield on the thickness of diamond crystals has been confirmed. A systematic quantitative investigation of the influence of the crystal thickness on the CR line shape has for the first time been performed. The mean-squared multiple-scattering angle effective for planar CR observed in forward direction has been found to be weaker as assumed from scattering in amorphous targets. Scaling laws deduced from the measured CR data are of advantage for the operation of a CR source. The second part of this thesis deals with the possibility of stimulation of CR emission by means of ultrasonic vibrations excited in a piezoelectric single crystal. Since the knowledge of the CR spectra generated on undisturbed quartz crystals is a necessary precondition for some investigation of the influence of US, planar CR has for the first time been measured at medium electron energies for a variety of planes in quartz. As a consequence of the hexagonal structure of this crystal, relative intense CR could be registered even out of planes with indices larger than one. On the base of the non-linear optics method, occupation functions and spectral distributions of planar CR have been calculated for channeling of 20 MeV electrons in the (01 anti 15) plane of a 20 μm thick quartz crystal at resonant influence of ultrasound (US). The resonance frequencies have been deduced from the measurements of CR spectra performed on quartz. First experimental investigations of the influence of US on CR started at ELBE aimed at the study of the effect of non-resonant ultrasonic vibrations excited in a 500 μm thick

  20. Investigation of planar channeling radiation on diamond and quartz crystals at electron energies between 14 and 34 MeV and probing the influence of ultrasonic waves on channeling radiation

    Energy Technology Data Exchange (ETDEWEB)

    Azadegan, B.

    2007-11-15

    Measurements of planar channeling radiation (CR) have been performed at the electron beam of ELBE within an energy range between 14 and 34 MeV and for thicknesses of the diamond crystals between 42.5 and 500 {mu}m. Absolute CR photon yields have for the first time been obtained for the above given ranges of electron energy and crystal thickness. The square-root dependence of the planar CR photon yield on the thickness of diamond crystals has been confirmed. A systematic quantitative investigation of the influence of the crystal thickness on the CR line shape has for the first time been performed. The mean-squared multiple-scattering angle effective for planar CR observed in forward direction has been found to be weaker as assumed from scattering in amorphous targets. Scaling laws deduced from the measured CR data are of advantage for the operation of a CR source. The second part of this thesis deals with the possibility of stimulation of CR emission by means of ultrasonic vibrations excited in a piezoelectric single crystal. Since the knowledge of the CR spectra generated on undisturbed quartz crystals is a necessary precondition for some investigation of the influence of US, planar CR has for the first time been measured at medium electron energies for a variety of planes in quartz. As a consequence of the hexagonal structure of this crystal, relative intense CR could be registered even out of planes with indices larger than one. On the base of the non-linear optics method, occupation functions and spectral distributions of planar CR have been calculated for channeling of 20 MeV electrons in the (01 anti 15) plane of a 20 {mu}m thick quartz crystal at resonant influence of ultrasound (US). The resonance frequencies have been deduced from the measurements of CR spectra performed on quartz. First experimental investigations of the influence of US on CR started at ELBE aimed at the study of the effect of non-resonant ultrasonic vibrations excited in a 500 {mu}m thick

  1. The source of multi spectral energy of solar energetic electron

    Energy Technology Data Exchange (ETDEWEB)

    Herdiwijaya, Dhani [Astronomy Division and Bosscha Observatory, Faculty Mathematics and Natural Sciences, Intitute Technology of Bandung, Ganesha 10, Bandung, Indonesia 40132 dhani@as.itb.ac.id (Indonesia)

    2015-04-16

    We study the solar energetic electron distribution obtained from ACE and GOES satellites which have different altitudes and electron spectral energy during the year 1997 to 2011. The electron spectral energies were 0.038–0.315 MeV from EPAM instrument onboard ACE satellite and >2 MeV from GOES satellite. We found that the low electron energy has no correlation with high energy. In spite of we have corrected to the altitude differences. It implied that they originated from time dependent events with different sources and physical processes at the solar atmosphere. The sources of multi spectral energetic electron were related to flare and CME phenomena. However, we also found that high energetic electron comes from coronal hole.

  2. Microscopic analysis of proton elastic scattering in the range 80-200 MeV

    International Nuclear Information System (INIS)

    Dietrich, F.S.; Petrovich, F.

    1983-01-01

    A systematic comparison is made of differential cross-section and analyzing-power data on 12 C, 28 Si, 40 Ca, 90 Zr, and 208 Pb at 80-200 MeV with calculations based on the single-step folding-model approach to the optical potential. In these calculations, proton densities have been inferred from electron scattering results, with neutron densities either the same as for protons ( 12 C, 28 Si, 40 Ca) or with a small neutron skin consistent with 800-MeV proton scattering results ( 80 Zr, 208 Pb). The effective two-body interactions that have been used are the Love-Franey t-matrix, a density-dependent interaction based on the Paris potential (calculated by von Geramb), and finally the Brieva-Rook density-dependent central interaction used with the spin-orbit part of the Love-Franey interaction

  3. Electron attachment to the SF{sub 6} molecule

    Energy Technology Data Exchange (ETDEWEB)

    Smirnov, B. M., E-mail: bmsmirnov@gmail.com; Kosarim, A. V. [Russian Academy of Sciences, Joint Institute for High Temperatures (Russian Federation)

    2015-09-15

    Various models for transition between electron and nuclear subsystems are compared in the case of electron attachment to the SF{sub 6} molecule. Experimental data, including the cross section of electron attachment to this molecule as a function of the electron energy and vibrational temperature, the rate constants of this process in swarm experiments, and the rates of the chemionization process involving Rydberg atoms and the SF{sub 6} molecule, are collected and treated. Based on the data and on the resonant character of electron capture into an autodetachment ion state in accordance with the Breit–Wigner formula, we find that intersection of the molecule and negative ion electron terms proceeds above the potential well bottom of the molecule with the barrier height 0.05–0.1 eV, and the transition between these electron terms has both the tunnel and abovebarrier character. The limit of small electron energies e for the electron attachment cross section at room vibrational temperature takes place at ε ≪ 2 meV, while in the range 2 meV ≪ ε ≪ 80 meV, the cross section is inversely proportional to ε. In considering the attachment process as a result of the interaction between the electron and vibrational degrees of freedom, we find the coupling factor f between them to be f = aT at low vibrational temperatures T with a ≈ 3 × 10{sup −4} K{sup −1}. The coupling factor is independent of the temperature at T > 400 K.

  4. The use of electron beams for pasteurization of meats

    International Nuclear Information System (INIS)

    Prestwich, K.R.; Kaye, R.J.; Turman, B.N.; Neau, E.L.

    1994-01-01

    Electron beam accelerators can be used for electronic pasteurization of meat products by: (1) using the electrons directly impacting the products, or (2) optimizing the conversion of electron energy to x-rays and treating the product with these x-rays. The choice of process depends on the configuration of the product when it is treated. For electron treatment, ten million electron volt (MeV) kinetic energy is the maximum allowed by international agreement. The depth of penetration of electrons with that energy into a product with density of meat is about five centimeters (cm). Two-sided treatment can be done on products up to 10 cm thick with a two-to-one ratio between minimum and maximum dose. Ground beef patties are about 1.25 cm (0.5 inch thick). Beams with 2.5 MeV electron energy could be used to treat these products. Our calculations show that maximum to minimum dose ratios less than 1.2 can be achieved with this energy if the transverse beam energy is small. If the product thickness is greater than 10 cm, x-rays can provide the needed dose uniformity. Uniform doses can be supplied for pallets with dimensions greater than 1.2 m on each side using x-rays from a 5 MeV electron beam. The efficiency of converting the electron beam to x-rays and configurations to achieve dose uniformity are discussed

  5. Annealing behaviour of MeV erbium implanted lithium niobate

    Energy Technology Data Exchange (ETDEWEB)

    Gortmaker, P.; McCallum, J.C. [Royal Melbourne Inst. of Tech., VIC (Australia)

    1993-12-31

    Lithium niobate (LiNbO{sub 3}) is a crystalline ceramic commonly used in the fabrication of optoelectronic devices. Recently, rare earth doping of LiNbO{sub 3} has become a topic of particular interest. The electronic configuration of rare earth elements such as Erbium (Er) and Neodymium (Nd) allows them to lase in nearly any host matrix making fabrication of a whole range of new optoelectronic devices possible. At present, the doping technique, for LiNbO{sub 3} are centred upon diffusion technology, but the diffusion profiles for the rare earths are not generally well-matched to the optical modes of the device. The aim of this research is to develop MeV implantation and annealing conditions of rare earth doped LiNbO{sub 3} that would be compatible with optoelectronic device fabrication. To determine the characteristics of the rare earth elements in the LiNbO{sub 3} host material over the depth range of interest in optoelectronic device applications, high energy Rutherford backscattering spectrometry and ion channeling (RBS-C) must be used. Presented here are the Er depth profile and lattice damage results obtained from 5 MeV RBS-C measurements on samples of LiNbO{sub 3} implanted with various doses of MeV Erbium and subsequently thermally annealed at a temperature of 1000 deg C. It was found that there is a peak implant concentration (2 x 10{sup 16} Er/cm{sup 2}) for which erbium no longer goes substitutional in the lattice, and the implantation damage is not fully removed by annealing. 8 refs., 3 figs.

  6. Annealing behaviour of MeV erbium implanted lithium niobate

    Energy Technology Data Exchange (ETDEWEB)

    Gortmaker, P; McCallum, J C [Royal Melbourne Inst. of Tech., VIC (Australia)

    1994-12-31

    Lithium niobate (LiNbO{sub 3}) is a crystalline ceramic commonly used in the fabrication of optoelectronic devices. Recently, rare earth doping of LiNbO{sub 3} has become a topic of particular interest. The electronic configuration of rare earth elements such as Erbium (Er) and Neodymium (Nd) allows them to lase in nearly any host matrix making fabrication of a whole range of new optoelectronic devices possible. At present, the doping technique, for LiNbO{sub 3} are centred upon diffusion technology, but the diffusion profiles for the rare earths are not generally well-matched to the optical modes of the device. The aim of this research is to develop MeV implantation and annealing conditions of rare earth doped LiNbO{sub 3} that would be compatible with optoelectronic device fabrication. To determine the characteristics of the rare earth elements in the LiNbO{sub 3} host material over the depth range of interest in optoelectronic device applications, high energy Rutherford backscattering spectrometry and ion channeling (RBS-C) must be used. Presented here are the Er depth profile and lattice damage results obtained from 5 MeV RBS-C measurements on samples of LiNbO{sub 3} implanted with various doses of MeV Erbium and subsequently thermally annealed at a temperature of 1000 deg C. It was found that there is a peak implant concentration (2 x 10{sup 16} Er/cm{sup 2}) for which erbium no longer goes substitutional in the lattice, and the implantation damage is not fully removed by annealing. 8 refs., 3 figs.

  7. Energy loss of carbon transmitted 1-MeV H2+ ions

    International Nuclear Information System (INIS)

    Fritz, M.; Kimura, K.; Susuki, Y.; Mannami, M.

    1994-01-01

    Energy losses of 1-MeV H 2 + ions passing through carbon foils of 2-8 μg/cm 2 thickness have been measured and show besides the linear increase with target thickness a 0.4 keV offset. The stopping power derived from the observed energy losses is 1.15 times as large as the sum of the stopping powers for two single H + of the same velocity. Calculations of the stopping powers for H 2 + ions and diprotons, using first Born approximation, indicate that the H 2 + ions lose the binding electron upon entrance into the foil, traverse the target as diprotons and recapture target electrons at the exit surface, a scenario also supported by the 0.4 keV offset at zero thickness. (author)

  8. Design study of an S-band RF cavity of a dual-energy electron LINAC for the CIS

    Science.gov (United States)

    Lee, Byeong-No; Park, Hyungdal; Song, Ki-baek; Li, Yonggui; Lee, Byung Cheol; Cha, Sung-su; Lee, Jong-Chul; Shin, Seung-Wook; Chai, Jong-seo

    2014-01-01

    The design of a resonance frequency (RF) cavity for the dual-energy S-band electron linear accelerator (LINAC) has been carried out for the cargo inspection system (CIS). This Standing-wave-type RF cavity is operated at a frequency under the 2856-MHz resonance frequency and generates electron beams of 9 MeV (high mode) and 6 MeV (low mode). The electrons are accelerated from the initial energy of the electron gun to the target energy (9 or 6 MeV) inside the RF cavity by using the RF power transmitted from a 5.5-MW-class klystron. Then, electron beams with a 1-kW average power (both high mode and low mode) bombard an X-ray target a 2-mm spot size. The proposed accelerating gradient was 13 MV/m, and the designed Q value was about 7100. On going research on 15-MeV non-destructive inspections for military or other applications is presented.

  9. Development of picosecond pulsed electron beam monitor. 2

    International Nuclear Information System (INIS)

    Hosono, Y.; Nakazawa, M.; Ueda, T.

    1994-01-01

    A picosecond pulsed electron beam monitor for a 35 MeV linear accelerator has been developed. The monitor consists of an electric SMA connector and aluminium pipe(inner diameter of 50mm). The following characteristics of this monitor were obtained, (a) the rise time is less than 17.5 ps (b) linearity of the monitor output voltage is proportional to the peak current of beam. It is shown that this monitor can be successfully used for bunch measurements of picosecond pulsed electron beam of 35 MeV linac. (author)

  10. Exposure of space electronics and materials to ionizing radiation

    DEFF Research Database (Denmark)

    Korsbech, Uffe C C

    1996-01-01

    Describes the methods and sources available for irradiation of space instruments developed at the Department of Automation. Methods for calculations and measurements of fluences and doses are also described. The sources are gamma-rays from iridium-192 and cobalt-60, 30 MeV protons, 10 MeV electrons...

  11. X-ray and γ-ray emission from channeled relativistic electrons and positrons

    International Nuclear Information System (INIS)

    Terhune, R.W.; Pantell, R.H.

    1977-01-01

    The characteristics of the radiation from channeled relativistic electrons and positrons are discussed and model calculations carried out. Radiation near 2.5 keV associated with transitions etween the 2 p→1s eigenstates of 2-MeV electrons channeled along the axis of MgO is predicted with 50 times the usual bremsstrahlung intensity in a 10% bandwidth. Recent low-energy bremsstrahlung measurements made with 28-MeV electrons propagating along an axis in silicon are interpreted in terms of this model

  12. Elastic neutron scattering studies at 96 MeV for transmutation.

    Science.gov (United States)

    Osterlund, M; Blomgren, J; Hayashi, M; Mermod, P; Nilsson, L; Pomp, S; Ohrn, A; Prokofiev, A V; Tippawan, U

    2007-01-01

    Elastic neutron scattering from (12)C, (14)N, (16)O, (28)Si, (40)Ca, (56)Fe, (89)Y and (208)Pb has been studied at 96 MeV in the10-70 degrees interval, using the SCANDAL (SCAttered Nucleon Detection AssembLy) facility. The results for (12)C and (208)Pb have recently been published, while the data on the other nuclei are under analysis. The achieved energy resolution, 3.7 MeV, is about an order of magnitude better than for any previous experiment above 65 MeV incident energy. A novel method for normalisation of the absolute scale of the cross section has been used. The estimated normalisation uncertainty, 3%, is unprecedented for a neutron-induced differential cross section measurement on a nuclear target. Elastic neutron scattering is of utmost importance for a vast number of applications. Besides its fundamental importance as a laboratory for tests of isospin dependence in the nucleon-nucleon, and nucleon-nucleus, interaction, knowledge of the optical potentials derived from elastic scattering come into play in virtually every application where a detailed understanding of nuclear processes is important. Applications for these measurements are dose effects due to fast neutrons, including fast neutron therapy, as well as nuclear waste incineration and single event upsets in electronics. The results at light nuclei of medical relevance ((12)C, (14)N and (16)O) are presented separately. In the present contribution, results on the heavier nuclei are presented, among which several are of relevance to shielding of fast neutrons.

  13. Secondary electron emission of thin carbon foils under the impact of hydrogen atoms, ions and molecular ions, under energies within the MeV range; Multiplicite des electrons secondaires emis par des cibles minces de carbone sous l'impact de projectiles H0, H2+, H3+ d'energie de l'ordre du MeV

    Energy Technology Data Exchange (ETDEWEB)

    Vidovic, Z

    1997-06-15

    This work focuses on the study of the emission statistics of secondary electrons from thin carbon foils bombarded with H{sup 0}, H{sub 2}{sup +} and H{sub 3}{sup +} projectiles in the 0.25-2.2 MeV energy range. The phenomenon of secondary electron emission from solids under the impact of swift ions is mainly due to inelastic interactions with target electrons. The phenomenological and theoretical descriptions, as well as a summary of the main theoretical models are the subject of the first chapter. The experimental set-up used to measure event by event the electron emission of the two faces of a thin carbon foil traversed by an energetic projectile is described in the chapter two. In this chapter are also presented the method and algorithms used to process experimental spectra in order to obtain the statistical distribution of the emitted electrons. Chapter three presents the measurements of secondary electron emission induced by H atoms passing through thin carbon foils. The secondary electron yields are studied in correlation with the emergent projectile charge state. We show the peculiar role of the projectile electron, whether it remains or not bound to the incident proton. The fourth chapter is dedicated to the secondary electron emission induced by H{sub 2}{sup +} and H{sub 3}{sup +} polyatomic ions. The results are interpreted in terms of collective effects in the interactions of these ions with solids. The role of the proximity of the protons, molecular ion fragments, upon the amplitude of these collective effects is evidenced from the study of the statistics of forward emission. These experiences allowed us to shed light on various aspects of atom and polyatomic ion inter-actions with solid surfaces. (author)

  14. Ion beam induced luminescence from diamond using an MeV ion microprobe

    Energy Technology Data Exchange (ETDEWEB)

    Bettiol, A.A.; Jamieson, D. N.; Prawer, S.; Allen, M.G. [Melbourne Univ., Parkville, VIC (Australia). School of Physics

    1993-12-31

    Analysis of the luminescence induced by a MeV ion beam offers the potential to provide useful information about the chemical properties of atoms in crystals to complement the information provided by more traditional Ion Beam Analysis (IBA) such as Rutherford Backscattering Spectrometry (RBS), ion channeling and Particle Induced X-ray Emission (PIXE). Furthermore, the large penetration depth of the MeV ion beam offers several advantages over the relatively shallow penetration of keV electrons typically employed in cathodoluminescence. An Ion Beam Induced Luminescence (IBIL) detection system was developed for the Melbourne microprobe that allows the spatial mapping of the luminescence signal along with the signals from RBS and PIXE. Homoepitaxial diamond growth has been studied and remarkable shifts in the characteristic blue luminescence of diamond towards the green were observed in the overgrowth. This has been tentatively identified as being due to transition metal inclusions in the epitaxial layers. 8 refs., 2 refs.

  15. Ion beam induced luminescence from diamond using an MeV ion microprobe

    Energy Technology Data Exchange (ETDEWEB)

    Bettiol, A A; Jamieson, D N; Prawer, S; Allen, M G [Melbourne Univ., Parkville, VIC (Australia). School of Physics

    1994-12-31

    Analysis of the luminescence induced by a MeV ion beam offers the potential to provide useful information about the chemical properties of atoms in crystals to complement the information provided by more traditional Ion Beam Analysis (IBA) such as Rutherford Backscattering Spectrometry (RBS), ion channeling and Particle Induced X-ray Emission (PIXE). Furthermore, the large penetration depth of the MeV ion beam offers several advantages over the relatively shallow penetration of keV electrons typically employed in cathodoluminescence. An Ion Beam Induced Luminescence (IBIL) detection system was developed for the Melbourne microprobe that allows the spatial mapping of the luminescence signal along with the signals from RBS and PIXE. Homoepitaxial diamond growth has been studied and remarkable shifts in the characteristic blue luminescence of diamond towards the green were observed in the overgrowth. This has been tentatively identified as being due to transition metal inclusions in the epitaxial layers. 8 refs., 2 refs.

  16. 1 1/2 years of experience with a 10 MeV self-shielded on-line e-beam sterilization system

    International Nuclear Information System (INIS)

    Lambert, Byron; Tang, Fuh-Wei; Riggs, Brian; Allen, Thomas; Williams, C.B.

    2000-01-01

    The Vascular Intervening Group of the Guidant Corporation (Guidant IV) has been operating a self-shielded, 10 MeV 4 kW, electron beam sterilization system since July of 1988. The system was designed, built and installed in a 70 square meter area in an existing Guidant manufacturing facility by Titan Scan Corporation and performance of the system was validated in conformance with 1S0-11137 standards. The goal of this on-site e-beam system was 'just in time' JIT, sterilization, i.e. the ability to manufacture, sterilize and ship, high intrinsic value medical devices in less than 24 hours. The benefits of moving from a long gas sterilization cycle of greater than one week to a JIT process were envisioned to be a) speed to market with innovated new products b) rapid response to customer requirements c) reduced inventory carrying costs and finally manufacturing and quality system efficiency. The ability of Guidant to realize these benefits depended upon the ability of the Guidant VI business units to adapt to the new sterilization modality and functionality and on the overall system reliability. This paper reviews the operating experience to date and the overall system reliability. (author)

  17. Dosimetric characteristics of a MOSFET dosimeter for clinical electron beams.

    Science.gov (United States)

    Manigandan, D; Bharanidharan, G; Aruna, P; Devan, K; Elangovan, D; Patil, Vikram; Tamilarasan, R; Vasanthan, S; Ganesan, S

    2009-09-01

    The fundamental dosimetric characteristics of commercially available metal oxide semiconductor field effect transistor (MOSFET) detectors were studied for clinical electron beam irradiations. MOSFET showed excellent linearity against doses measured using an ion chamber in the dose range of 20-630cGy. MOSFET reproducibility is better at high doses compared to low doses. The output factors measured with the MOSFET were within +/-3% when compared with those measured with a parallel plate chamber. From 4 to 12MeV, MOSFETs showed a large angular dependence in the tilt directions and less in the axial directions. MOSFETs do not show any dose-rate dependence between 100 and 600MU/min. However, MOSFETs have shown under-response when the dose per pulse of the beam is decreased. No measurable effect in MOSFET response was observed in the temperature range of 23-40 degrees C. The energy dependence of a MOSFET dosimeter was within +/-3.0% for 6-18MeV electron beams and 5.5% for 4MeV ones. This study shows that MOSFET detectors are suitable for dosimetry of electron beams in the energy range of 4-18MeV.

  18. Investigation of the dynamics of dissipative U+Au collisions with δ-electron spectroscopy

    International Nuclear Information System (INIS)

    Stroth, J.; Dahlinger, M.; Konen, W.; Stiebing, K.

    1997-01-01

    δ-electron emission in elastic and dissipative collisions of U+Au at E/A=8.65 MeV has been investigated. The velocity vectors of the reaction products were measured in coincidence with electrons of energies up to 3.2 MeV. The δ-electron yield measured for elastic collisions is in good agreement with coupled-channel calculations. The δ-electron spectra of dissipative reactions show a clear dependence on the violence of the collision, i.e. the total kinetic energy loss (TKEL). The shape of the spectra are analysed with an atomic model by a fitting procedure using phenomenological trajectories. The results indicate an increasing contact time of the united system with increasing total kinetic energy loss reaching 1.16(4) x 10 -21 s at left angle TKEL right angle =375 MeV. (orig.). With 2 figs

  19. Variable Energy 2-MeV S-Band Linac for X-ray and Other Applications

    International Nuclear Information System (INIS)

    Howard Bender; Dave Schwellenbach; Ron Sturges; Rusty Trainham

    2008-01-01

    We will describe the design and operation of a compact, 2-MeV, S-band linear accelerator (linac) with variable energy tuning and short-pulse operation down to 15 ps with 100-A peak current. The design consists of a buncher cavity for short-pulse operation and two coupled resonator sections for acceleration. Single-pulse operation is accomplished through a fast injector system with a 219-MHz subharmonic buncher. The machine is intended to support a variety of applications, such as X-ray and electron beam diagnostic development and, recently, electron diffraction studies of phase transitions in shocked materials

  20. Variable Energy 2-MeV S-Band Linac for X-ray and Other Applications

    International Nuclear Information System (INIS)

    H. Bender; D. Schwellenbach; R. Sturges; R. Trainham

    2008-01-01

    This paper describes the design and operation of a compact, 2-MeV, S-band linear accelerator (linac) with variable energy tuning and short-pulse operation down to 15 ps with 100-A peak current. The design consists of a buncher cavity for short-pulse operation and two coupled resonator sections for acceleration. Single-pulse operation is accomplished through a fast injector system with a 219-MHz subharmonic buncher. The machine is intended to support a variety of applications, such as x-ray and electron beam diagnostic development, and recently, electron diffraction studies of phase transitions in shocked materials

  1. Photonuclear fission with quasimonoenergetic electron beams from laser wakefields

    International Nuclear Information System (INIS)

    Reed, S. A.; Chvykov, V.; Kalintchenko, G.; Matsuoka, T.; Rousseau, P.; Yanovsky, V.; Vane, C. R.; Beene, J. R.; Stracener, D.; Schultz, D. R.; Maksimchuk, A.

    2006-01-01

    Recent advancements in laser wakefield accelerators have resulted in the generation of low divergence, hundred MeV, quasimonoenergetic electron beams. The bremsstrahlung produced by these highly energetic electrons in heavy converters includes a large number of MeV γ rays that have been utilized to induce photofission in natural uranium. Analysis of the measured delayed γ emission demonstrates production of greater than 3x10 5 fission events per joule of laser energy, which is more than an order of magnitude greater than that previously achieved. Monte Carlo simulations model the generated bremsstrahlung spectrum and compare photofission yields as a function of target depth and incident electron energy

  2. Observation of the two-electron cusp in atomic collisions. Evidence for strong electron-electron correlation

    International Nuclear Information System (INIS)

    Sarkadi, L.; Orban, A.

    2007-01-01

    Complete text of publication follows. In this report we present experimental data for a process when two electrons with velocity vectors equal to that of the projectile are emitted from collisions. By observing the two electron cusp the study of the threshold phenomenon for two-electron break-up is possible. It is a particularly interesting question whether the outgoing charged projectile can attract the two repulsing electrons so strongly that the two-electron cusp is formed. If it is so, a further question arises: Are the two electrons correlated in the final state as it is predicted by the Wannier theory? The experiments have been done at the 1 MeV VdG accelerator of ATOMKI using our TOF spectrometer. The first measurements clearly showed the formation of the two-electron cusp and signature of the electron correlation in 200 keV He 0 +He collisions. These promising results motivated us to carry out the experiment at 100 keV beam energy where the coincidence count rate is still reasonable but the energy resolution is better. For an acceptable data acquisition time we improved our data acquisition and data processing system for triple coincidence measurements. In Fig. 1a we present our measured relative fourfold differential cross section (FDCS) that shows strong electron correlation. For a comparison, in Fig. 1b we displayed the contour plot for uncorrelated electron pair emission. These latter data were synthesized artificially, generating the energies of the electron pairs from two independent double coincidence experiments. In both figures the distributions are characterized by two ridges. In Fig. 1b the ridges are perpendicular straight lines (E 1 = E 2 .13.6 eV). As a result of the correlation, the ridges in Fig. 1a are distorted in such a way that they have a joint straight-line section following the line E 1 + E 2 = 27.2 eV. This means that the electron pairs in the vicinity of the cusp maximum are emitted with a center of- mass velocity equal to that of

  3. Andromede project: Surface analysis and modification with probes from hydrogen to nano-particles in the MeV energy range

    International Nuclear Information System (INIS)

    Eller, Michael J.; Cottereau, Evelyne; Rasser, Bernard; Verzeroli, Elodie; Agnus, Benoit; Gaubert, Gabriel; Donzel, Xavier; Delobbe, Anne; Della-Negra, Serge

    2015-01-01

    The Andromede project is the center of a multi-disciplinary team which will build a new instrument for surface modification and analysis using the impact of probes from hydrogen to nano-particles (Au 400 +4 ) in the MeV range. For this new instrument a series of atomic, polyatomic, molecular and nano-particle ion beams will be delivered using two ion sources in tandem, a liquid metal ion source and an electron cyclotron resonance source. The delivered ion beams will be accelerated to high energy with a 4 MeV van de Graaff type accelerator. By using a suite of probes in the MeV energy range, ion beam analysis techniques, MeV atomic and cluster secondary ion mass spectrometry can all be performed in one location. A key feature of the instrument is its ability to produce an intense beam for injection into the accelerator. The commissioning of the two sources shows that intense beams from atomic ions to nano-particles can be delivered for subsequent acceleration. The calculations and measurements for the two sources are presented.

  4. Drift-resonant, relativistic electron acceleration at the outer planets: Insights from the response of Saturn's radiation belts to magnetospheric storms

    Science.gov (United States)

    Roussos, E.; Kollmann, P.; Krupp, N.; Paranicas, C.; Dialynas, K.; Sergis, N.; Mitchell, D. G.; Hamilton, D. C.; Krimigis, S. M.

    2018-05-01

    The short, 7.2-day orbital period of Cassini's Ring Grazing Orbits (RGO) provided an opportunity to monitor how fast the effects of an intense magnetospheric storm-time period (days 336-343/2016) propagated into Saturn's electron radiation belts. Following the storms, Cassini's MIMI/LEMMS instrument detected a transient extension of the electron radiation belts that in subsequent orbits moved towards the inner belts, intensifying them in the process. This intensification was followed by an equally fast decay, possibly due to the rapid absorption of MeV electrons by the planet's main rings. Surprisingly, all this cycle was completed within four RGOs, effectively in less than a month. That is considerably faster than the year-long time scales of Saturn's proton radiation belt evolution. In order to explain this difference, we propose that electron radial transport is partly controlled by the variability of global scale electric fields which have a fixed local time pointing. Such electric fields may distort significantly the orbits of a particular class of energetic electrons that cancel out magnetospheric corotation due to their westward gradient and curvature drifts (termed "corotation-resonant" or "local-time stationary" electrons) and transport them radially between the ring current and the radiation belts within several days and few weeks. The significance of the proposed process is highlighted by the fact that corotation resonance at Saturn occurs for electrons of few hundred keV to several MeV. These are the characteristic energies of seed electrons from the ring current that sustain the radiation belts of the planet. Our model's feasibility is demonstrated through the use of a simple test-particle simulation, where we estimate that uniform but variable electric fields with magnitudes lower that 1.0 mV/m can lead to a very efficient transport of corotation resonant electrons. Such electric fields have been consistently measured in the magnetosphere, and here we

  5. Linac-beam characterizations at 600 MeV using optical transition radiation diagnostics.

    Energy Technology Data Exchange (ETDEWEB)

    Lumpkin, A. H.

    1998-05-27

    Selected optical diagnostics stations were upgraded in anticipation of low-emittance, bright electron beams from a thermionic rf gun or a photoelectric rf gun on the Advanced Photon Source (APS) injector linac. These upgrades include installation of optical transition radiation (OTR) screens, transport lines, and cameras for use in transverse beam size measurements and longitudinal profile measurements. Using beam from the standard thermionic gun, tests were done at 50 MeV and 400 to 650 MeV. Data were obtained on the limiting spatial ({sigma} {approximately} 200 {micro}m) and temporal resolution (300 ms) of the Chromox (Al{sub 2}O{sub 3} : Cr) screen (250-{micro}n thick) in comparison to the OTR screens. Both charge-coupled device (CCD) and charge-injection device (CID) video cameras were used as well as the Hamamatsu C5680 synchroscan streak camera operating at a vertical deflection rate of 119.0 MHz (the 24th subharmonic of the S-band 2856-MHz frequency). Beam transverse sizes as small as {sigma}{sub x} = 60 {micro}m for a 600-MeV beam and micropulse bunch lengths of {sigma}{sub {tau}}<3 ps have been recorded for macropulse-averaged behavior with charges of about 2 to 3 nC per macropulse. These techniques are applicable to linac-driven, fourth-generation light source R and D experiments including the APS's SASE FEL experiment.

  6. An analytical expression for electron elastic scattering cross section from atoms and molecules in 1.0 keV to 1.0 MeV energy range

    Energy Technology Data Exchange (ETDEWEB)

    Yalcin, S. [Education Faculty, Kastamonu University, 37200 Kastamonu (Turkey)]. E-mail: yalcin@gazi.edu.tr; Gurler, O. [Physics Department, Faculty of Arts and Sciences, Uludag University, Gorukle Campus, 16059 Bursa (Turkey); Gultekin, A. [Physics Department, Faculty of Arts and Sciences, Uludag University, Gorukle Campus, 16059 Bursa (Turkey); Gundogdu, O. [School of Engineering, University of Surrey, Guildford, GU2 7XH (United Kingdom)]. E-mail: o.gundogdu@surrey.ac.uk

    2006-07-31

    In this Letter, an expression is presented to calculate elastic scattering cross sections for incident electrons as a function of both energy and atomic number in the energy range between 1 keV and 1 MeV for materials with effective atomic number between 3 and 18. The expression we present has a rather simple analytical form which gives accurate results that are in very good agreement with the results calculated by a relativistic partial-wave expansion method. Hence, this equation can be employed accurately and efficiently in a continuous manner, without the need to go through rather large look-up tables, thus making the whole process quick, efficient and removing possible computational errors that may arise from the efforts of interpolation.

  7. An analytical expression for electron elastic scattering cross section from atoms and molecules in 1.0 keV to 1.0 MeV energy range

    International Nuclear Information System (INIS)

    Yalcin, S.; Gurler, O.; Gultekin, A.; Gundogdu, O.

    2006-01-01

    In this Letter, an expression is presented to calculate elastic scattering cross sections for incident electrons as a function of both energy and atomic number in the energy range between 1 keV and 1 MeV for materials with effective atomic number between 3 and 18. The expression we present has a rather simple analytical form which gives accurate results that are in very good agreement with the results calculated by a relativistic partial-wave expansion method. Hence, this equation can be employed accurately and efficiently in a continuous manner, without the need to go through rather large look-up tables, thus making the whole process quick, efficient and removing possible computational errors that may arise from the efforts of interpolation

  8. Web based electronic log book for Indus-2

    International Nuclear Information System (INIS)

    Srivastava, B.S.K.; Fatnani, P.

    2011-01-01

    Raja Ramanna Centre for Advanced Technology (RRCAT), Indore, India has a 20 MeV Microtron injector, a 450/700 MeV Booster Synchrotron, a 450 MeV Storage Ring Indus-1 and another 2.5 GeV Storage Ring Indus-2. Both the machines are national facilities and are run round the clock to provide synchrotron radiation to users as well as carrying out machine related studies. In a multi accelerator complex like this, an effective system for electronically recording experimental data, machine status, events etc is considered essential. Considering the advantages of Internet technologies, a first version of web based Electronic Logbook (Elogbook) has been developed using HTML, JavaScript, java servlets and SQL database. This Elogbook will provide convenient way to review machine performance, help in problem diagnosis and improve communications among working teams. (author)

  9. Patterned microstructures formed with MeV Au implantation in Si(1 0 0)

    International Nuclear Information System (INIS)

    Rout, Bibhudutta; Greco, Richard R.; Zachry, Daniel P.; Dymnikov, Alexander D.; Glass, Gary A.

    2006-01-01

    Energetic (MeV) Au implantation in Si(1 0 0) (n-type) through masked micropatterns has been used to create layers resistant to KOH wet etching. Microscale patterns were produced in PMMA and SU(8) resist coatings on the silicon substrates using P-beam writing and developed. The silicon substrates were subsequently exposed using 1.5 MeV Au 3+ ions with fluences as high as 1 x 10 16 ions/cm 2 and additional patterns were exposed using copper scanning electron microscope calibration grids as masks on the silicon substrates. When wet etched with KOH microstructures were created in the silicon due to the resistance to KOH etching cause by the Au implantation. The process of combining the fabrication of masked patterns with P-beam writing with broad beam Au implantation through the masks can be a promising, cost-effective process for nanostructure engineering with Si

  10. Dose conversion coefficients for electron exposure of the human eye lens

    International Nuclear Information System (INIS)

    Behrens, R; Dietze, G; Zankl, M

    2009-01-01

    Recent epidemiological studies suggest a rather low dose threshold (below 0.5 Gy) for the induction of a cataract of the eye lens. Some other studies even assume that there is no threshold at all. Therefore, protection measures have to be optimized and current dose limits for the eye lens may be reduced in the future. Two questions arise from this situation: first, which dose quantity is related to the risk of developing a cataract, and second, which personal dose equivalent quantity is appropriate for monitoring this dose quantity. While the dose equivalent quantity H p (0.07) has often been seen as being sufficiently accurate for monitoring the dose to the lens of the eye, this would be questionable in the case when the dose limits were reduced and, thus, it may be necessary to generally use the dose equivalent quantity H p (3) for this purpose. The basis for a decision, however, must be the knowledge of accurate conversion coefficients from fluence to equivalent dose to the lens. This is especially important for low-penetrating radiation, for example, electrons. Formerly published values of conversion coefficients are based on quite simple models of the eye. In this paper, quite a sophisticated model of the eye including the inner structure of the lens was used for the calculations and precise conversion coefficients for electrons with energies between 0.2 MeV and 12 MeV, and for angles of radiation incidence between 0 deg. and 45 deg. are presented. Compared to the values adopted in 1996 by the International Commission on Radiological Protection (ICRP), the new values are up to 1000 times smaller for electron energies below 1 MeV, nearly equal at 1 MeV and above 4 MeV, and by a factor of 1.5 larger at about 1.5 MeV electron energy.

  11. Monokinetic electron backsttering from amorphous or polycrystalline specimens

    International Nuclear Information System (INIS)

    Ahmed, H.E.D.H.

    1983-06-01

    We have considered the interaction of electrons with thin amorphous specimens: one part of these electrons is transmitted through the substance, the other being backscattered. This last phenomena, which is not perfectly understood, has been studied in the energy range from 0.3 to 3 MeV. First this work deals with the realization of a fully automatic apparatus which has been adapted to the column of the 3 MeV electron microscope of the HVFM laboratory in Toulouse. The variation of the transmission and backscattering coefficients, for amorphous and polycrystalline specimens, is determined. From this coefficient the electron range in this substance can be deduced. In addition the experimental results can be used to understand the image contrast in scanning electron microscopy. A short presentation of the cross-section, introduces the theoretical study of Monte-Carlo calculation. The Monte-Carlo calculation is used to take into account all elementary processus, which take place during electron scattering [fr

  12. Parameterization of neutron production double-differential cross section above several tens-MeV by the use of moving source model

    International Nuclear Information System (INIS)

    Kitsuki, Hirohiko; Shigyo, Nobuhiro; Ishibashi, Kenji

    2000-01-01

    The moving source model based on the Maxwell-like energy distribution with Gaussian shape terms are employed for analyzing the neutron emission spectra from proton-induced spallation reaction. The parallelization of the double differential cross section is made for the experimental and calculated neutron data in the energy region from several-tens MeV to 3 GeV. (author)

  13. Sewage sludge irradiation with electrons

    International Nuclear Information System (INIS)

    Tauber, M.

    1976-01-01

    The disinfection of sewage sludge by irradiation has been discussed very intensively in the last few months. Powerful electron accelerators are now available and the main features of the irradiation of sewage sludge with fast electrons are discussed and the design parameters of such installations described. AEG-Telefunken is building an irradiation plant with a 1.5 MeV, 25 mA electron accelerator, to study the main features of electron irradiation of sewage sludge. (author)

  14. An electron cooling device in the one MeV energy region

    International Nuclear Information System (INIS)

    Busso, L.; Tecchio, L.; Tosello, F.

    1987-01-01

    The project of an electron cooling device at 700 KeV electron energy is reported. The single parts of the device is described in detail. Electron beam diagnostics and technical problems is discussed. The electron gun, the accelerating/decelerating column and the collector have been studied by menas of the Herrmannsfeldt's program and at present are under construction. The high voltage system and the electron cooling magnet are also under construction. Vacuum tests with both hot and cold cathodes have demonstrated that the vacuum requirements can be attained by the use of non-evaporable getter (NEG) pumps between gun, collector and the cooling region. Both kinds of diagnostic for longitudinal and transversal electron temperature measurements are in progress. A first prototype of the synchronous picj-up was successfully tested at CERN SPS. At present the diagnostic with laser beam is in preparation. During the next year the device will be assembled and the laboratory test will be started

  15. High Power Electron Accelerator Prototype

    CERN Document Server

    Tkachenko, Vadim; Cheskidov, Vladimir; Korobeynikov, G I; Kuznetsov, Gennady I; Lukin, A N; Makarov, Ivan; Ostreiko, Gennady; Panfilov, Alexander; Sidorov, Alexey; Tarnetsky, Vladimir V; Tiunov, Michael A

    2005-01-01

    In recent time the new powerful industrial electron accelerators appear on market. It caused the increased interest to radiation technologies using high energy X-rays due to their high penetration ability. However, because of low efficiency of X-ray conversion for electrons with energy below 5 MeV, the intensity of X-rays required for some industrial applications can be achieved only when the beam power exceeds 300 kW. The report describes a project of industrial electron accelerator ILU-12 for electron energy up to 5 MeV and beam power up to 300 kW specially designed for use in industrial applications. On the first stage of work we plan to use the existing generator designed for ILU-8 accelerator. It is realized on the GI-50A triode and provides the pulse power up to 1.5-2 MW and up to 20-30 kW of average power. In the report the basic concepts and a condition of the project for today are reflected.

  16. Spin excitations in 48Ca and 90Zr with 319 MeV protons

    International Nuclear Information System (INIS)

    Nanda, S.K.

    1985-05-01

    Cross sections, analyzing powers, and spin-flip probabilities have been measured in the low momentum transfer region in the 90 Zr(p vector, p' vector) 90 Zr* reaction at 319 MeV. A rich fine structure is observed for the first time in inelastic proton scattering in the previously proposed M1 giant resonance region. Angular distribution of most of these states are consistent with M1 excitation. The excitation energies of the fine structure states are in good agreement with similar structure seen in electron scattering; however, discrepancies in spin assignments remain. The measured cross section for the entire bump is about 37 +- 10% of the Distorted Wave Impulse Approximation (DWIA) prediction for the M1 strength in 90 Zr with simple wave functions. However, an analysis of the fine structure states reveals about 15% of the strength in the M1 region to be due to narrow El states; another 8% is attributed to M2 strength. The spin-flip measurements for 90 Zr reveal a large spin-flip probability value for the M1 region; good agreement is obtained with DWIA calculations. However, a large cross section for spin excitations distributed uniformly over the excitation energy region from about 7 to 25 MeV is observed for the first time. The spin excitation strength in this giant resonance continuum is found to about 0.80 mb/sr/MeV. Angular distributions for the spin-flip cross sections from 7 to 18 MeV in steps of 2 MeV have been analyzed with low multipole spin excitation calculations in the DWIA framework; the observed spin-flip strength in this region is found to be consistent with spin excitation involving angular momentum transfer of up to two. Finally, cross section, analyzing power, and spin-flip probability data have also been obtained for the 10.23 MeV M1 transition in the 48 Ca(p vector, p' vector) 48 Ca* reaction at 319 MeV. The quenching of M1 strength in 48 Ca relative to theoretical predictions is found to be consistent with previous work

  17. The reaction p12C→ηX from Tp=800 MeV to Tp=1500 MeV

    International Nuclear Information System (INIS)

    Chiavassa, E.; Dellacasa, G.; De Marco, N.; De Oliveira Martins, O.; Gallio, M.; Guaita, P.; Musso, A.; Piccotti, A.; Scomparin, E.; Vercellin, E.

    1998-01-01

    The reaction p 12 C→nX has been studied, at several proton kinetic energies ranging from 800 MeV to 1500 MeV, at the proton synchrotron Saturne at Saclay. The measured doubly differential cross-sections are presented and discussed in the framework of a simple theoretical model. The model fails in describing the deepest subthreshold data while the above-threshold data are fairly well reproduced. (orig.)

  18. Single-electron tunneling in InP nanowires

    NARCIS (Netherlands)

    Franceschi, De S.; Dam, Van J.A.; Bakkers, E.P.A.M.; Feiner, L.F.; Gurevich, L.; Kouwenhoven, L.P.

    2003-01-01

    A study was performed on single-electron tunneling in InP nanowires. The contact resistances as low as ~10 k¿, with minor temperature dependence were obtained. The Coulomb-blockade behavior was shown with single-electron charging energies of ~1 meV.

  19. Review of neutron data: 10 to 40 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Haight, R.C.

    1977-04-01

    Neutron data are reviewed for incident neutron energies between 10 and 40 MeV. A census of the data shows that there are many gaps in this range and that the existing data are primarily for neutron energies around 14 MeV. Aside from total cross sections, there are few data between 10 and 13 MeV and between 15 and 40 MeV. Examples are presented to show the quality of selected data for total, elastic, inelastic, activation, and charged-particle and gamma-ray production cross sections. The spectra of emitted particles are also discussed.

  20. Review of neutron data: 10 to 40 MeV

    International Nuclear Information System (INIS)

    Haight, R.C.

    1977-04-01

    Neutron data are reviewed for incident neutron energies between 10 and 40 MeV. A census of the data shows that there are many gaps in this range and that the existing data are primarily for neutron energies around 14 MeV. Aside from total cross sections, there are few data between 10 and 13 MeV and between 15 and 40 MeV. Examples are presented to show the quality of selected data for total, elastic, inelastic, activation, and charged-particle and gamma-ray production cross sections. The spectra of emitted particles are also discussed